G2 1 32 Updated 102241 Catalog
2014-07-05
: Pdf 102241-Catalog 102241-Catalog 781381 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 37
Download | |
Open PDF In Browser | View PDF |
G2-1 Incandescent Lighting: Explosionproof A-51® Groups C & D EHL Handlamp Description 5-11 A-51® Series Lighting Fixtures— Class I, Groups C and D 2,3 Features 4 Classified Area Suitability, Weights 5,6 Ordering Information 7 Mounting Hoods, Fixture Units, Globes and Guards 8 Reflectors, Colored Globes, and Parts 9 Dimensions 10, 11 Photometrics 12,15 A-51® Series Lighting Fixtures— Class I, Groups A and B 2,3 Features 12 Ordering Information and Reflectors 13 Mounting Hoods, Fixture Units, Globes, Guards and Parts 14 Dimensions 15 Photometrics 16 AHL and EHL Portable Handlamps 16 Features 17 Fixtures, Parts and Dimensions 18 EDT Lighting Fixtures and Accessories 19-24 ELS Series Emergency Lighting System 19 Features 20-22 Ordering Information 23 Replacement Parts and Technical Data 24 Weights and Dimensions 25-31 Code-Master™ Strobe and Beacon Factory Sealed Lighting Fixtures 25 Features 26 Order Information and Technical Data 27-29 Fixtures 30 Optional Guard and Replacement Parts 31 Dimensions ELS Series Code•Master™ Strobe Effective September, 2005 Copyright 2005 G A-51® Groups A & B Page See Section Q for Explosionproof Floodlights. 800-621-1506 www.appletonelec.com PAGE 1 G2-2 A-51® Incandescent Explosionproof Lighting Fixtures: Factory Sealed Suitable for use in Wet Locations. UNILETS¨ for use with Threaded Metal Conduit. Applications A-51 Series Incandescent Class I, Groups A, B, C and D; Class II, E, F and G applications (see listings and area suitability chart). Ideal for use in chemical and petrochemical plants and in other heavy process areas where ignitable vapors, dust, moisture and corrosive atmospheres may be present. Suitable for use in wet locations. Wide range of wattages — 60 thru 500 watt incandescent lamps. Choice of units with or without guard as well as choice of porcelain or polyester reflectors. Choice of mountings — pendant, ceiling, stanchion, long bracket and short bracket. Porcelain reflectors for standard applications and fiberglass reinforced polyester reflectors for installations where fixture is subject to exceptionally severe corrosive atmospheres. High bay reflector for installations where mounting height from work plane ranges from 20 to 30 feet. Class I, Groups A and B fixtures have special UL approved sintered metal flame arrester. • • G • • • • • • Features • All A-51 fixtures are factory sealed— no external sealing fittings are required. New high temp phenolic connection block in mounting hood has rugged leaf spring contacts—loosen two screws, rotate and remove for quick wiring. Safe, easy servicing or relamping without disconnecting any wiring. “Wireless” fixture unit easily threads off mounting hood for convenient servicing or for immediate exchange with “stand-by” unit. All joints are flame tight. • • • Effective September, 2005 Copyright 2005 PAGE 2 800-621-1506 www.appletonelec.com A-51® Incandescent Explosionproof Lighting Fixtures: Factory Sealed G2-3 Suitable for use in Wet Locations. UNILETS® for use with Threaded Metal Conduit. • Specially formulated two coat baked • Class • • • epoxy enamel provides superior protective finish to resist corrosion. Applied to all mounting hoods, fixture units and guards. N ew h i g h t e m p e ra t u r e g l a s s reinforced phenolic socket block in fixture unit has collector ring and pin which automatically makes electrical contact as fixture unit is threaded onto mounting hood. Globes in A-51 fixtures are explosion-proof and heat and impact resisting glass. Prismatic configuration on globe interior provides light control while allowing smooth exterior surface for cleaning. A-51 fixture units have standardized threads to fit all A-51 and mounting hoods. All fixtures have Alzak® aluminum inner reflector for increased lumen efficiency. A-51 fixture guards are of rugged copper-free aluminum construction and double epoxy coated—provide protection to globe. Easily mounts to globe ring with 3 screws. I,* Div. 1 and 2, Groups A,B,C,D. Class II,* Div. 1 and 2, Groups E,F,G. *Some models. Suitable for use in wet locations. Appleton malleable iron products conform to ASTM A47-77, Grade 32510, which has the following properties: tensile strength, 50,000 psi; yield, 32,000 psi; and elongation, 10%. • Appleton a l u m i nu m p r o d u c t s are produced from a high strength copper-free (4/10 of 1% max.) alloy. Product Cross Reference See general introduction to catalog for information on fixture selection. For HID fixtures with integral ballasts, see Code•Master Series in catalog section G1. Fluorescent fixtures are in section F3 and G3. • • G • • Porcelain • Standard Materials Fixtures and guards: copper-free aluminum (4/10 of 1%). Pendant mounting hoods: copperfree aluminum (4/10 of 1%). Ceiling and bracket mounting hoods: malleable iron with aluminum adapters. Reflectors: porcelain enameled steel, Alzak aluminum or fiberglass reinforced polyester. • • • • Standard Finishes guards and mounting hoods: two coat epoxy-clad finish. Epoxy powder coat finish, electrostatically applied for complete, uniform surface protection. Steel reflectors: white porcelain enamel. Polyester and Alzak aluminum reflectors: natural finish. • Fixtures, • • Compliances UL Listed. UL 1598 and 844. • • Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 3 G2-4 A-51® Incandescent Fixtures Classified Area Suitability and Weights Class I Div. 1 and Div. 2 Groups C and D Lamp Watts Without Reflectors Standard Dome 30˚ Angle High Bay Supply Wire AAU1N 100W A19 100W A21 T5 T5 T5 T5 T5 T5 _ _ 125°C 125°C AAU15N 150W 200W 200W 300W A23 A25 PS25 PS25 T3C T3C T3C T3C T3C T3C T3C T3A T3C T3C T3C T3A (D) _ _ _ _ 125°C 125°C 125°C 125°C AAU2NS 200W 200W 300W 300W PS25 PS30 PS25 PS30 T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C _ _ _ _ 110°C 110°C 110°C 110°C AAU5NS 500W PS35 500W PS40 T3C T3C T3C T3C T3C T3C _ _ 135°C 135°C G Fixture Unit Class I Div. 1 and Div. 2 Groups A, B, C and D AAUA15 150W 150W 200W 200W A23 A25 A25 PS25 T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C _ _ _ _ 110°C 110°C 110°C 110°C AAUA2 200W 200W 300W 300W PS25 PS30 PS25 PS30 T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C _ _ _ _ 110°C 110°C 110°C 110°C Class II Div. 1 and Div. 2 Groups E, F and G AAU1N 100W A19 100W A21 T3C T3C T3C T3C T3C T3C _ _ 125°C 125°C AAU15N 150W 200W 200W 300W A23 A25 PS25 PS25 T3C T3C T3 T3 T3C T3C T3 T3C T3C T3 _ _ _ _ 125°C 125°C 125°C 125°C AAU2NS 200W 200W 300W 300W PS25 PS30 PS25 PS30 T3C T3C T3C T3C T3C T3C T3C T3C T3C T3C T3A (EF) T3A (EF) _ _ _ _ 110°C 110°C 110°C 110°C AAU5NS 500W PS35 500W PS40 T3C T3C T3C T3C T3C T3C _ _ 135°C 135°C Group A Pendant Mount only. NOTE: Ambient suitability of these incandescent fixtures: 40° C Weights Fixture Units Cat. No. Wt., Lbs. Mounting Hoods Cat. No. Wt., Lbs. Guards Cat. No. AAU-1N AAU-15N AAU-2NS AAU-5NS AAUA-15 AAUA-2 Pendant Ceiling Stanchion Long Bracket Short Bracket AAGU-1 AAGU-2 AAGU-5 AAGUA-15 7.6 7.6 10.7 20.3 15.0 18.0 Effective September, 2005 Copyright 2005 PAGE 4 1.3 4.8 1.6 8.9 4.8 Wt., Lbs. .4 .8 1.9 .5 Standard Reflectors Cat. No. Wt., Lbs. 30˚ Angle Reflectors Cat. No. Wt., Lbs. High Bay Reflectors Cat. No. Wt., Lbs. AARP-2ST AARW-15ST AARW-2ST AARW-5ST AARW-15ST AARP-2AN AARW-15AN AARW-2AN AARW-5AN AARW-15AN AARE-2HB AARE-5HB 2.8 2.1 2.9 4.3 2.1 3.3 2.1 2.4 7.0 2.1 2.9 3.9 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G* Class III A-51® Incandescent Explosionproof Lighting Fixtures: Factory Sealed G2-5 Suitable for use in Wet Locations. UL 1598, UL 844 Hub Size (Inches) Catalog Number 60-100 Watt (AAU-1N) A-21 1/2 3/4 1 AP1050 AP1075 AP10100 150-300 Watt (AAU-15N) A-23 PS-25 1/2 3/4 1 AP1550 AP1575 AP15100 200-300 Watt (AAU-2NS) PS-30 1/2 3/4 1 AP2050 AP2075 AP20100 300-500 Watt (AAU-5NS) PS-35 1/2 3/4 1 AP5050 AP5075 AP50100 60-100 Watt (AAU-1N) A-21 1/2 3/4 1 AC1050 AC1075 AC10100 150-300 Watt (AAU-15N) A-23 PS-25 1/2 3/4 1 AC1550 AC1575 AC15100 200-300 Watt (AAU-2NS) PS-30 1/2 3/4 1 AC2050 AC2075 AC20100 300-500 Watt (AAU-5NS) PS-35 1/2 3/4 1 AC5050 AC5075 AC50100 60-100 Watt (AAU-1N) A-21 1-1/2◆ AN10150 150-300 Watt (AAU-15N) A-23 PS-25 1-1/2◆ AN15150 200-300 Watt (AAU-2NS) PS-30 1-1/2◆ AN20150 300-500 Watt (AAU-5NS) PS-35 1-1/2◆ AN50150 Type Pendant One hub, rigid or flexible mounting. G Ceiling Four hubs and three close-up plugs. 25° Stanchion (Not UL Listed) One hub *For specific classified area suitability of each fixture listed, see table on page G2-4. ◆1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 5 G2-6 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G* Class III A-51® Incandescent Explosionproof Lighting Fixtures: Factory Sealed Suitable for use in Wet Locations. UL 1598, UL 844 Hub Size (Inches) Catalog Number 60-100 Watt (AAU-1N) A-21 1/2 3/4 1 ALB1050 ALB1075 ALB10100 150-300 Watt (AAU-15N) A-23 PS-25 1/2 3/4 1 ALB1550 ALB1575 ALB15100 200-300 Watt (AAU-2NS) PS-30 1/2 3/4 1 ALB2050 ALB2075 ALB20100 300-500 Watt (AAU-5NS) PS-35 1/2 3/4 1 ALB5050 ALB5075 ALB50100 60-100 Watt (AAU-1N) A-21 1/2 3/4 ASB1050 ASB1075 150-300 Watt (AAU-15N) A-23 PS-25 1/2 3/4 ASB1550 ASB1575 200-300 Watt (AAU-2NS) PS-30 1/2 3/4 ASB2050 ASB2075 Type Long Bracket Four hubs and three close-up plugs G 15° Short Bracket Two hubs and one close-up plug Three-Way Exit Sign Epoxy enameled steel — 6”-high red lettering CJEXRN 60-200W (Mounts to AAU-1N or AAU-15N fixture units in place of guard) Single Sided Exit Sign Epoxy enameled steel — 6”-high red lettering AEXR-15R 60-200W (Mounts to AAU-1N or AAU-15N fixture units in place of guard) (See page G2-24 for dimensions) Accessories Add Suffix to Fixture Catalog Number Guard Standard Dome Reflector 30˚ Angle Reflector High Bay Reflector Suffix -G -ST -AN -HB *For specific classified area suitability of each fixture listed, see table on page G2-4. Effective September, 2005 Copyright 2005 PAGE 6 800-621-1506 www.appletonelec.com A-51 Incandescent Explosionproof Lighting Fixtures: Mounting Hoods, Fixture Units, Globes, Guards ® G2-7 Copper-Free Aluminum Fixture with Gray Epoxy Finish. Mounting Hoods in Aluminum and Malleable Iron.* Type Hub Size (Inches) Catalog Number 1/2 3/4 1 AAP-50 AAP-75 AAP-100 1/2 3/4 1 AAC-50 AAC-75 AAC-100 1-1/2 AAN-150† 1/2 3/4 1 AALB-50 AALB-75 AALB-100 1/2 3/4 AASB-50 AASB-75 Mounting Hoods* Pendant One hub, rigid or flexible mounting Ceiling G Four hubs and three close-up plugs 25° Stanchion (Not UL Listed) One hub Long Bracket Four hubs and three close-up plugs 15° Short Bracket Two hubs and one close-up plug Fixture Units 60-100W A-21 150-300W A-23 & PS-25 200-300W PS-30 300-500W PS-35 AAU-1N AAU-15N AAU-2NS AAU-5NS Prismatic Glass Globes 60-100W (AAU-1N) 150-300W (AAU-15N) 200-300W (AAU-2NS) 300-500W (AAU-5NS) AAGL-1PR AAGL-1PR AAGL-2PR AAGL-5PR Aluminum Guards 60-100W (AAU-1N) 150-300W (AAU-15N) 200-300W (AAU-2NS) 300-500W (AAU-5NS) AAGU-1 AAGU-1 AAGU-2 AAGU-5 †1-1/2” Tapped hub furnished with a 1-1/2” to 1-1/4” reducer. * Pendant and stanchion mounting hoods are copper-free aluminum. Ceiling and bracket types are malleable iron with aluminum adapters. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 7 G2-8 A-51® Incandescent Explosionproof Lighting Fixtures: Reflectors, Colored Globes, Parts Porcelain, Alzak Aluminum or Polyester Reflectors. Fixture Size Catalog Number Porcelain and Polyester Reflectors G Standard Dome (Not for use with short brackets) Porcelain 60-100W (AAU-1N) 150-300W (AAU-15N) 200-300W (AAU-2NS) 300-500W (AAU-5NS) AARW-15ST AARW-15ST AARW-2ST AARW-5ST 30˚ Angle 60-100W (AAU-1N) 150-300W (AAU-15N) 200-300W (AAU-2NS) 300-500W (AAU-5NS) AARW-15AN AARW-15AN AARW-2AN AARW-5AN Polyester AARP-2ST AARP-2AN Alzak Aluminum Reflectors High Bay 200-300W (AAU-2NS) 300-500W (AAU-5NS) AARE-2HB AARE-5HB Colored Glass Globes Amber 60-100W (AAU-1N) 150-300W (AAU-15N) 200-300W (AAU-2NS) Green 60-100W (AAU-1N) 150-300W (AAU-15N) 200-300W (AAU-2NS) Red 60-100W (AAU-1N) 150-300W (AAU-15N) 200-300W (AAU-2NS) AAGL-1A AAGL-1A AAGL-2A AAGL-1G AAGL-1G AAGL-2G AAGL-1R AAGL-1R AAGL-2R Replacement Socket 60-100W (AAU-1N)—Medium Base 150-300W (AAU-15N)—Medium Base 200-300W (AAU-2NS)—Medium Base 300-500W (AAU-5NS)—Mogul Base AASP-11 AASP-22 AASP-22 AASP-44 Connection Block 60-500W. Fits A-51 Mounting Hoods VPT-7 Globe Gaskets—Fiber and Aluminum Requires one of each 60-300W (AAU-1N and AAU-15N) 200-300W (AAU-2NS) 300-500W (AAU-NS) Effective September, 2005 Copyright 2005 PAGE 8 Fiber AASP-15V AASP-2V AASP-5V Aluminum AASP-15A AASP-2A AASP-5A 800-621-1506 www.appletonelec.com G2-9 Dimensions: A-51® Incandescent Lighting Fixtures A-51 Lighting Fixtures Stanchion B C A Ceiling B C A Long Bracket B C A B C Short Bracket A B C Dimensions in Inches 60-100 11.47 10.85 11.50 12.25 11.63 7.06 13.75 13.13 7.06 13.75 13.13 12.38 13.56 12.94 9.13 150-300 11.47 10.85 11.50 12.25 11.63 7.06 13.75 13.13 7.06 13.75 13.13 12.38 13.56 12.94 9.13 200-300 13.07 12.38 12.71 13.94 13.25 8.81 15.44 14.75 8.81 15.50 14.75 13.25 15.19 14.50 10.13 300-500 15.09 14.34 14.64 16.00 15.25 12.13 17.50 17.75 12.13 17.50 16.75 14.88 17.25 16.50 11.94 Dimensions in Centimeters 60-100 29.1 27.6 29.2 31.1 29.5 17.9 34.9 33.3 17.9 34.9 33.3 31.4 34.4 32.9 23.2 150-300 29.1 27.6 29.2 31.1 29.5 17.9 34.9 33.3 17.9 34.9 33.3 31.4 34.4 32.9 23.2 200-300 33.2 31.4 32.3 35.4 33.7 22.4 39.2 37.5 22.4 39.4 37.5 33.7 38.6 36.8 25.7 300-500 38.3 36.4 37.2 40.6 38.7 30.8 44.5 45.1 30.8 44.5 42.5 37.8 43.8 41.9 30.3 ◆For dimensions of fixture unit only, subtract pendant hood dimension 1.31” (3.3cm) from dimensions A and B as listed. A-51 Reflectors* Size (Watts) A B A B A B Dimensions in Inches 60-100 12.00 4.50 10.00 7.63 — — 150-200 14.00 4.38 10.00 7.63 — — 200-300 16.00 5.19 12.00 7.88 12.00 6.06 300-500 20.00 6.84 18.00 13.13 18.00 9.13 Dimensions in Centimeters 60-100 30.5 11.4 25.4 19.4 — 150-200 35.6 11.1 25.4 19.4 — — — 200-300 40.6 13.2 30.5 20.0 30.5 15.4 300-500 50.8 17.4 45.7 33.3 45.7 23.2 *Dimensions illustrated are for porcelain steel (dome and angle) and etched Alzak aluminum (high bay). Overall dimensions for fiberglass reinforced polyester reflectors are: standard dome—16-1/2” dia., 6” high; 30° Angle—14-3/8” dia., 10” high. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 9 G Size (Watts) A Pendant◆ G2-10 Photometric Data: A-51® Incandescent Explosionproof Lighting Fixtures Class I, Groups C and D Fixtures. A-51 Incandescent Fixture without Reflector Spacing to Mtg. Ht. Ratio 1.25:1 Guard .877 Effective Floor Cavity Reflectance (Rfc) is 20% 80 % Ceiling Rcc ROOM CAVITY RATIOS % Walls Rw 50 30 70 10 50 30 50 10 50 30 30 10 50 30 10 10 50 30 0 10 0 1 .735 .690 .651 .695 .655 .618 .622 .590 .561 .554 .530 .506 .493 .473 .454 .422 2 .621 .558 .503 .588 .530 .481 .525 .478 .437 .467 .430 .396 .413 .384 .357 .327 3 .540 .468 .411 .512 .446 .394 .457 .404 .359 .406 .363 .327 .360 .325 .294 .267 4 .474 .400 .342 .450 .381 .328 .402 .346 .301 .359 .312 .274 .318 .280 .248 .223 5 .415 .341 .284 .394 .325 .272 .354 .295 .251 .316 .266 .229 .280 .240 .207 .184 6 .372 .297 .245 .352 .284 .233 .316 .258 .215 .283 .234 .197 .252 .210 .178 .157 7 .334 .262 .213 .317 .249 .203 .285 .227 .187 .255 .207 .170 .228 .187 .155 .136 8 .300 .231 .182 .285 .221 .175 .256 .202 .162 .231 .183 .148 .206 .165 .135 .117 9 .271 .204 .157 .258 .195 .152 .233 .178 .140 .209 .162 .128 .187 .146 .117 .100 10 .246 .181 .139 .234 .175 .135 .212 .160 .124 .191 .145 .113 .172 .132 .102 .087 A-51 Incandescent Fixture with Standard Dome Reflector Spacing to Mtg. Ht. Ratio 1.25:1 Guard .890 Effective Floor Cavity Reflectance (Rfc) is 20% 80 % Ceiling Rcc % Walls ROOM CAVITY RATIOS G Coefficients of Utilization: Zonal Cavity Method Photometric data shown here is based on a 200 watt type PS-30 lamp and is representative of the performance for all A-51 incandescent fixtures using 60 watt to 500 watt lamps. For candlepower values of fixtures with other lamps, use the following multipliers: 60 watt A-19—.23; 100 watt A-19—.47; 150 watt A-21—.75; 200 watt A-23—1.07; 200 watt A-25—1.02; 200 watt PS-25—1.03: 300 watt PS-25—1.70; 300 watt PS-30—1.63; 300 watt PS-35—1.55; 500 watt PS-35— 2.95; 500 watt PS-40—2.69. To determine candlepower values of fixtures with a guard, multiply by value shown with each curve. Effective September, 2005 Copyright 2005 PAGE 10 Rw 50 30 70 10 50 30 50 10 50 30 30 10 50 30 10 10 50 30 0 10 0 1 .757 .727 .700 .740 .713 .689 .709 .686 .667 .681 .663 .646 .656 .641 .627 .612 2 .660 .613 .572 .647 .603 .567 .621 .585 .552 .598 .568 .540 .577 .551 .528 .512 3 .580 .524 .478 .570 .516 .475 .549 .504 .466 .529 .490 .458 .511 .478 .449 .434 4 .514 .452 .403 .504 .446 .400 .486 .436 .395 .469 .425 .390 .454 .415 .384 .368 5 .451 .385 .336 .442 .380 .334 .427 .372 .332 .413 .364 .327 .399 .357 .323 .308 6 .402 .336 .291 .394 .333 .286 .381 .326 .285 .369 .319 .282 .358 .313 .279 .264 7 .361 .296 .254 .355 .293 .250 .343 .286 .247 .332 .282 .245 .323 .278 .243 .229 8 .323 .261 .216 .318 .258 .216 .308 .254 .215 .299 .249 .213 .290 .245 .211 .197 9 .291 .230 .187 .287 .227 .187 .278 .223 .186 .269 .219 .184 .262 .216 .182 .169 10 .264 .204 .166 .259 .204 .166 .253 .200 .164 .245 .197 .162 .240 .194 .161 .149 800-621-1506 www.appletonelec.com Photometric Data: A-51® Incandescent Explosionproof Lighting Fixtures G2-11 Class I, Groups C and D Fixtures. Coefficients of Utilization: Zonal Cavity Method Photometric data shown here is based on a 200 watt type PS-30 lamp and is representative of the performance for all A-51 incandescent fixtures using 60 watt to 500 watt lamps. For candlepower values of fixtures with other lamps, use the following multipliers: 60 watt A-19—.23; 100 watt A-19—.47; 150 watt A-21—.75; 200 watt A-23—1.07; 200 watt A-25—1.02; 200 watt PS-25—1.03: 300 watt PS-25—1.70; 300 watt PS-30—1.63; 300 watt PS-35—1.55; 500 watt PS-35— 2.95; 500 watt PS-40—2.69. To determine candlepower values of fixtures with a guard, multiply by value shown with each curve. A-51 Incandescent Fixture with High Bay Reflector Spacing to Mtg. Ht. Ratio 1.40:1 Guard .865 G Effective Floor Cavity Reflectance (Rfc) is 20% 80 % Ceiling Rcc ROOM CAVITY RATIOS % Walls Rw 50 30 70 10 50 30 50 10 50 30 30 10 50 30 10 10 50 30 0 10 0 1 .686 .644 .645 .671 .651 .634 .644 .628 .614 .620 .607 .595 .598 .588 .577 .566 2 .614 .580 .549 .603 .571 .545 .581 .555 .531 .562 .540 .520 .544 .525 .508 .496 3 .550 .508 .473 .542 .501 .470 .524 .490 .461 .507 .478 .454 .492 .467 .446 .434 4 .493 .445 .408 .486 .441 .404 .470 .431 .400 .456 .422 .395 .443 .413 .389 .377 5 .439 .387 .349 .432 .383 .347 .420 .376 .344 .407 .369 .340 .396 .383 .336 .324 6 .393 .340 .304 .387 .338 .300 .376 .331 .298 .366 .326 .296 .356 .320 .293 .281 7 .352 .299 .264 .347 .296 .261 .337 .290 .258 .327 .287 .256 .320 .283 .254 .242 8 .313 .261 .224 .309 .259 .223 .300 .255 .222 .293 .251 .220 .285 .247 .219 .207 9 .280 .228 .191 .276 .225 .191 .268 .222 .190 .261 .219 .189 .254 .216 .187 .176 10 .252 .201 .168 .248 .201 .168 .242 .197 .167 .236 .195 .165 .231 .192 .164 .153 A-51 Incandescent Fixture with 30˚ Reflector B—Back S—Side F—Front G—Front W.Guard Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 11 G2-12 Class I, Div. 1 and 2 Groups A◆,B,C,D Class II, Div. 1 and 2 Groups E,F,G Class III UL 1598, UL 844 Listed A-51® Incandescent Groups A and B Explosionproof Lighting Fixtures: Factory Sealed Suitable for use in Wet Locations. Fixture Type and Type Hub Size (Inches) Catalog Number 60-200 Watt (AAUA-15) PS-25 1/2 3/4 AAPA1550 AAPA1575 200-300 Watt (AAUA-2) PS-30 1/2 3/4 AAPA2050 AAPA2075 60-200 Watt (AAUA-15) PS-25 1/2 3/4 AACA1550 AACA1575 200-300 Watt (AAUA-2) PS-30 1/2 3/4 AACA2050 AACA2075 60-200 Watt (AAUA-15) PS-25 1/2 3/4 AASBA1550 AASBA1575 200-300 Watt (AAUA-2) PS-30 1/2 3/4 AASBA2050 AASBA2075 Pendant One hub, rigid or flexible mounting. Ceiling G Four hubs and three close-up plugs. 15˚ Short Bracket Two hubs and one close-up plug. Accessories Add suffix to fixture catalog number Suffix Guard Standard Dome Reflector 30˚ Angle Reflector -G -ST -AN Porcelain Steel and Polyester Reflectors Porcelain Polyester Standard Dome 60-200 Watt (AAUA-15) 200-300 Watt (AAUA-2) AARW-15ST AARW-2ST AARP-2ST 30˚ Angle 60-200 Watt (AAUA-15) 200-300 Watt (AAUA-2) AARW-15AN AARW-2AN AARP-2AN ◆ Shaded area indicates pendant mount is suitable for Class I, Group A in addition to other applicable area suitabilities. For specific classified area suitability of each fixture, see page G2-4. Effective September, 2005 Copyright 2005 PAGE 12 800-621-1506 www.appletonelec.com G2-13 A-51® Incandescent Groups A† and B Explosionproof Lighting Fixtures: Mounting Hoods, Fixtures and Parts Mounting Hoods in Aluminum and Malleable Iron.* Copper-Free Aluminum Fixture with Gray Epoxy Finish. Type Hub Size (Inches) Catalog Number 1/2 3/4 AAP-50† AAP-75† 1/2 3/4 AAC-50 AAC-75 1/2 3/4 AASB-50 AASB-75 Mounting Hoods Pendant One hub, rigid or flexible mounting Ceiling G Four hubs and three close-up plugs 15˚ Short Bracket Two hubs and one close-up plug Fixture Units 60-200 Watt PS-25 AAUA-15 200-300 Watt PS-30 AAUA-2 Globe and Ring Assembly 60-200 Watt (AAUA-15) AAGLA-15 200-300 Watt (AAUA-2) AAGLA-2 Aluminum Guards 60-200 Watt (AAUA-15) AAGUA-15 200-300 Watt (AAUA-2) AAGU-2 Medium Base Lamp Socket 60-200 Watt (AAUA-15) AASPA-15 200-300 Watt (AAUA-2) AASPA-22 Connection Block Fits all A-51 and AA-51 mounting hoods 60-300 Watt VPT-7 † Group A pendant mount only. * Pendant mounting hoods are copper-free aluminum. Ceiling and bracket types are malleable iron with aluminum adapters. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 13 G2-14 Dimensions: A-51® Groups A and B Incandescent Lighting Fixtures G Ceiling Pendant Pendant Size (Watts) A Short Bracket Ceiling Short Bracket B C A B C A B C Dimensions in Inches 60-200 13.69 13.13 7.06 16.50 15.94 7.06 15.00 14.44 9.50 200-300 14.75 13.69 8.81 17.56 16.50 8.81 16.00 15.44 10.38 Dimensions in Centimeters 60-200 34.8 33.3 17.9 41.9 40.5 17.9 38.1 36.7 24.1 200-300 37.5 34.8 22.4 44.6 41.9 22.4 40.6 39.2 26.4 Effective September, 2005 Copyright 2005 PAGE 14 800-621-1506 www.appletonelec.com Photometric Data: A-51® Incandescent Explosionproof Lighting Fixtures G2-15 Class I, Groups A and B Fixtures. Photometric data shown here is based on a 200 watt type PS-25 lamp, and is representative of the performance for A-51 incandescent fixtures (Groups A and B). For candlepower values of fixtures with other lamps, use the following multipliers: 150 watt (PS-25), .70; 300 watt (PS-25), 1.6. To determine candlepower values of fixtures with a guard, multiply by value shown with each curve. Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector) 80 % Ceiling Rcc % Walls Rw 50 30 70 10 50 30 50 10 50 30 30 10 50 30 10 10 50 30 0 10 0 1 .711 .669 .630 .669 .631 .595 .590 .560 .533 .518 .495 .473 .452 .434 .417 .383 2 .602 .541 .488 .567 .511 .465 .499 .455 .416 .437 .402 .371 .380 .352 .327 .296 3 .519 .449 .393 .488 .424 .374 .430 .379 .336 .375 .335 .300 .325 .292 .264 .236 4 .456 .384 .328 .430 .364 .312 .379 .325 .282 .332 .288 .252 .288 .252 .223 .197 5 .400 .328 .274 .378 .311 .260 .334 .278 .236 .293 .247 .211 .254 .217 .187 .164 6 .357 .285 .234 .336 .270 .221 .297 .242 .200 .261 .215 .180 .227 .188 .159 .138 7 .318 .248 .200 .300 .234 .190 .265 .209 .171 .233 .187 .153 .204 .165 .135 .116 8 .287 .219 .172 .270 .208 .164 .240 .187 .149 .212 .167 .134 .104 .147 .119 .101 9 .260 .194 .150 .246 .185 .143 .218 .166 .130 .192 .148 .117 .168 .131 .103 .087 10 .236 .173 .132 .222 .166 .126 .199 .149 .114 .175 .133 .102 .154 .117 .090 .075 Effective Floor Cavity Reflectance (Rfc) is 20% (Std. Dome Reflector) 80 % Ceiling Rcc ROOM CAVITY RATIOS % Walls Rw 50 30 70 10 50 30 50 10 50 30 30 10 50 30 10 10 50 30 0 10 0 1 .797 .763 .733 .779 .748 .721 .745 .720 .697 .715 .695 .676 .689 .671 .655 .640 2 .687 .633 .586 .673 .622 .581 .645 .603 .566 .620 .585 .553 .597 .567 .541 .524 3 .594 .530 .478 .583 .522 .474 .560 .508 .464 .538 .494 .457 .519 .481 .448 .431 4 .527 .458 .404 .517 .452 .400 .497 .440 .395 .479 .430 .390 .462 .419 .384 .366 5 .466 .393 .340 .456 .388 .337 .440 .379 .335 .424 .371 .330 .410 .364 .326 .310 6 .414 .342 .292 .406 .339 .288 .391 .331 .286 .378 .324 .283 .367 .317 .280 .264 7 .369 .298 .252 .362 .294 .248 .350 .288 .245 .337 .284 .242 .328 .279 .240 .225 8 .333 .265 .217 .327 .262 .216 .316 .257 .215 .307 .252 .213 .297 .248 .211 .196 9 .302 .235 .189 .297 .232 .189 .287 .229 .188 .278 .224 .186 .270 .221 .185 .170 10 .273 .209 .167 .268 .209 .167 .261 .204 .166 .253 .201 .163 .247 .198 .162 .149 Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 15 G ROOM CAVITY RATIOS Coefficients of Utilization: Zonal Cavity Method G2-16 AHL and EHL Incandescent Explosionproof Lighting Fixtures and Handlamp: Factory Sealed Suitable for use in Wet Locations. Applications AHL general purpose Explosionproof lighting fixture - an A-51 fixture with handle assembly of hook and cable clamp. CAUTION: For safe operation, the AHL fixture weight must be suppor ted by the hanger hook, not by the flexible cord, per NEC 502-11(a)(3). EHL general purpose Explosionproof portable handlamp. Only 5” in diameter for ease of movement. The EHL handlamp may be used with AE Automatic Take-Up Reelites listed in Catalog Subsection W3 and ECC Cord Connector and Plugs and Receptacles in Catalog Section L. • • G • Features: AHL and EHL • Equipped with connection block for ease of wiring and relamping. • Cable clamp diameters: AHL— .375” to .625”. EHL—.406” for 16-3 AWG. • Heat- and impact-resistant glass globes. AHL Features • Sturdy fixture with rugged hanging hook. • Safety grounding — additional terminal furnished to connect to grounding conductor. EHL Features • Portability, with phenolic handle and non-sparking guard with hook. • Easy relamping — loosen setscrew, unscrew guard, remove globe and insert lamp. Safety grounding — remove cable and clamp and make connections to terminal (including one ground terminal) then tighten clamp. • Standard Materials Globes: heat-and impact-resistant glass. AHL fixture unit, hook and guard: copper-free aluminum. AHL cable clamp: brass. EHL fixture body and handle: laminated phenolic. EHL handle: laminated phenolic. EHL hook: brass. EHL guard: copper-free aluminum. • • • • • • • Effective September, 2005 Copyright 2005 PAGE 16 Standard Finishes AHL fixture unit, guard, handle and hook: two-coat epoxy enamel. AHL cable clamp: natural finish. EHL fixture body: laminated phenolic. EHL handle: phenolic. EHL guard and hook: guard — natural finish, hook — zinc electroplate and clear chromate. EHL cable clamp: laminated phenolic. • • • • • • Compliances • UL Standard 1598 (supersedes UL 57) and 844. • Suitable for use in wet locations. • Appleton malleable iron products conform to ASTM A47-77, Grade 32510, which has the following properties: tensile strength, 50,000 psi; yield, 32,000 psi; and elongation, 10%. A p p l e t o n a l u m i nu m p r o d u c t s are produced from a high strength copper-free (4/10 of 1% max.) alloy. • 800-621-1506 www.appletonelec.com AHL: Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups F†,G Class III EHL: Class I, Div. 1 and 2 Groups C,D U.S. Pat. 3,170,750 Pat. Can. 1968 G2-17 AHL and EHL Incandescent Explosionproof Lighting Fixtures and Handlamp: Factory Sealed Suitable for use in Wet Locations. Cable Dia. (Inches) Description T Ratings Catalog Number AHL—Explosionproof 60-300W Lighting Fixtures Class I, Groups C and D; Class II, Groups F and G CAUTION: For safe operation, weight of fixture must be supported by hanger hook, not by the flexible cord, per NEC 502-11(a)3. .375 to .625 T4 AHL100 200-300 Watt, PS-30 (AAU-2NS) .375 to .625 T4A AHL200 T3A EHL100N *EHL—Explosionproof 100W Portable Handlamp Laminated Phenolic Handle. Wiring Connection Block takes from #16 to #14 Wire. Class I, Groups C and D 100 Watt, A-21 .406 EHL Replacement Globe and Guard XP419 XP163SA Heat-resistant glass globe Aluminum guard with hook † To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are not electrically conductive). *Handlamp accommodates 16-3 SO cable. Consult factory if 14-3 cable is required. AHL Dimensions Dim. in Inches Cat. No., A Dim. in B C Centimeters A B C AHL100 14.25 7.06 10.94 36.2 17.9 27.8 AHL200 15.94 8.81 12.63 40.5 22.4 32.1 EHL Dimensions Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 17 G 60-100 Watt, A-21 (AAU-1N) G2-18 Class II, Div. 1 and 2 Groups E,F,G Class III EDT Incandescent Dust-Ignitionproof Lighting Fixtures and Accessories UL 1598, UL 844 Suitable for use in Wet Locations. Watts Hub Size Catalog Number 1/2” EDTP2050 Pendant Lighting Fixture* One tapped opening for rigid or flexible mounting, with heat resistant clear globe 60-200 Watt Fixture Accessories and Parts G Heat Resistant Clear Glass Globe 60-200 Watt VSGL-2HR Globe Guard 60-200 Watt DPGU-2 Replacement Porcelain Shock-Absorbing Socket Medium Base 60-200 Watt VPLR-123 * T3C maximum operating temperature. Supply wire 150°C. Maximum ambient temperature 25°C. Vertical mount only (globe down). Effective September, 2005 Copyright 2005 PAGE 18 800-621-1506 www.appletonelec.com G2-19 ELS Series Emergency Lighting System: Explosionproof, Dust-Ignitionproof Remote and direct mounted fixtures for hazardous location applications Applications ELS Series features an emergency lighting power unit that is designed to provide safe operation in the presence of hazardous gasses, vapors, or dusts, defined by the National Electrical Code as Class I, Groups C and D, and Class II, Groups E,F,G. Typical applications include all means of egress (such as walkways, exit ramps, stairs and aisles) for hazardous areas which include oil refineries, petrochemical facilities, pulp and paper mills, chemical storage areas, waste water treatment facilities and grain elevators. • • G Features The electronics consist of a solidstate charger, transfer circuit and low voltage battery disconnect circuit. The unit test switch and AC “On” indicator light are housed in a separate module that may be attached directly to the unit housing or mounted remotely for ease of testing. All ELS Series units are rated for operation in NEC Class I, Divisions 1 or 2 Groups C and D and Class II, Divisions 1 or 2 Groups E, F, and G environment. Housing provisions allow for the attachment of two optional Explosionproof lighting fixtures. Unit capacity is sufficient for the connection of up to four, 6- or 12- volt, 18-watt fixtures Units provide 90 minutes of emergency operation. The solid-state charger maintains battery at full charge. Upon failure of utility voltage, the DC emergency lighting load is connected to the battery. During emergency operation, automatic battery protection from deep discharge damage is provided by a low-voltage battery disconnect (LVD) circuit. Upon restoration of normal power, the charger will begin a recharge cycle. It will bring the battery to full capacity within acceptable UL time standards. A pilot light indicates the presence of AC line voltage, and a test switch is provided for checking transfer operation. • • • • • • • • • • • Effective September, 2005 Copyright 2005 Lock out type guard on push button accepts locks with up to 1/4” hasp. A universal transformer allows operation on 120 or 277 VAC lines. Emergency power source is a maintenance-free, sealed, pure-lead battery suited for harsh temperature environments for 0° to 40°C. Expected life is 10 years Compact in design. Never necessary to add water. Standard illumination is provided using fixtures specially designed for emergency lighting in hazardous environments, supplied with double contact bayonet base 18 or 28-watt incandescent lamps. Designed for easy installation. Provided with 4 mounting holes for attachment to a wall or other suitable surface. Mounting hardware not included. Housing is drilled and tapped for installation of utility 1/2” NPT conduit. Quick access to internal wiring and components is provided by thread-on cover. All necessary fittings for test switch/ pilot light module supplied standard. • • • • • • • • • • • C e i l i n g a n d b r a cke t m o u n t s : Malleable Iron with aluminum adapter. • Pe n d a n t m o u n t : C o p p e r Fr e e Aluminum. • Reflectors: Porcelain enameled steel. • Test Switch: Copper free Aluminum with stainless steel hardware. Standard Finishes • Enclosure, Fixtures and Test Station: Epoxy Powder Coat Finish Electrostatically applied for complete and uniform surface protection Steel Reflectors: White Porcelain Enamel. • Options • The fixture may be adapted to serve as an exit sign through use of an Auxiliary Exit Housing. Time Delay Relay (15 min.) available to permit normal lighting to re-establish brightness. Add suffix T1 for 120 VAC or T2 for 277 VAC. • Compliances • UL 844 • UL 924 • NFPA101 (Life Safety Code) Standard Materials • Battery Enclosure: Copper Free Aluminum. • Fixtures and guards: Copper Free Aluminum. 800-621-1506 www.appletonelec.com PAGE 19 G2-20 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Class III ELS Series Emergency Lighting System: Explosionproof, Dust-Ignitionproof Remote and direct mounted fixtures for hazardous location applications Catalog Numbering Logic for Emergency Lighting System ELS 2 Series 18 6 Wattage per lamp 18 - 18 Watt 28 - 28 Watt G # 0 1 2 of direct mounted fixtures - no direct mounted fixtures - 1 direct mounted fixture - 2 direct mounted fixtures T1G Options T1 - Time delay relay, 120 VAC input T2 - Time delay relay, 277 VAC input G - Guard installed on fixture Lamp Voltage 6 - 6 VDC 12 - 12 VDC Reflectors and exit signs ordered separately. See accessories page. Capacity of standard ELS unit (75 Watt for 90 minutes). Up to 2 fixtures may be direct mounted. The remainder must be remote mounted. Combination Number Number of Fixtures Wattage per Fixture Total Wattage 1 2 3 4 5 6 1 1 2 2 3 1 2 4 18 28 18 28 18 28 18 18 18 28 36 56 54 64 7 72 * Consult factory for Class I, Group B rating. Effective September, 2005 Copyright 2005 PAGE 20 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III G2-21 ELS Series Emergency Lighting System: Explosionproof, Dust-Ignitionproof Remote and direct mounted fixtures for hazardous location applications Emergency Lighting System with Direct Mounted Fixtures Watts per Lamp Lamp Voltage 2 2 2 2 1 1 1 1 18 28 18 28 18 28 18 28 6 VDC 6 VDC 12 VDC 12 VDC 6 VDC 6 VDC 12 VDC 12 VDC Input Voltage 120/277 120/277 120/277 120/277 120/277 120/277 120/277 120/277 VAC VAC VAC VAC VAC VAC VAC VAC Catalog Number (Lamp(s) Included) ELS2186 ELS2286 ELS21812 ELS22812 ELS1186 ELS1286 ELS11812 ELS12812 ❶❷❸❹ ❶❷❸❹ ❶❷❸❹ ❶❷❸❹ ❶❷❸❹ ❶❷❸❹ ❶❷❸❹ ❶❷❸❹ Emergency Lighting System Enclosure with Battery and Charger Lamp Voltage Input Voltage 6 VDC 12 VDC 120/277 VAC 120/277 VAC Catalog Number with Push-to-Test (Incl. Fittings) ELS06 ❶❷❸ ELS012 ❶❷❸ Emergency Lighting System Fixture for Direct Mounting to Enclosure Includes all necessary fittings and lamp. ❶ ❷ ❸ ❹ Watts Per Lamp Lamp Voltage Catalog Number Lamp Included 18 28 18 28 6 VDC 6 VDC 12 VDC 12 VDC AP1050-186-DM AP1050-286-DM AP1050-1812-DM AP1050-2812-DM ❹ ❹ ❹ ❹ 1/2” NPT provided for AC input. Add suffix T1 for time delay relay for 120 VAC input. Add suffix T2 for time delay relay for 277 VAC input. To order fixtures with guard installed add suffix – G. Reflectors and exit signs are ordered separately. See accessories page. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 21 G Number of Fixtures G2-22 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Class III ELS Series Emergency Lighting System: Explosionproof, Dust-Ignitionproof Remote and direct mounted fixtures for hazardous location applications Emergency Lighting System Fixture for Remote Mounting Lamp included G Pendant Mount Long Bracket Mount Ceiling Mount Mounting Type Short Bracket Mount Watts Per Lamp Lamp Voltage Catalog Number Lamp Included ❶ Pendant One 1/2” Hub 18 28 18 28 6 VDC 6 VDC 12 VDC 12 VDC AP1050-186 AP1050-286 AP1050-1812 AP1050-2812 Ceiling Four 1/2” Hubs, Three Close-Up Plugs 18 28 18 28 6 VDC 6 VDC 12 VDC 12 VDC AC1050-186 AC1050-286 AC1050-1812 AC1050-2812 Long Bracket Four 1/2” Hubs, Three Close-Up Plugs 18 28 18 28 6 VDC 6 VDC 12 VDC 12 VDC ALB1050-186 ALB1050-286 ALB1050-1812 ALB1050-2812 Short Bracket (15 degrees) Two 1/2” Hubs, One Close-Up Plug 18 28 18 28 6 VDC 6 VDC 12 VDC 12 VDC ASB1050-186 ASB1050-286 ASB1050-1812 ASB1050-2812 Emergency Lighting System Replacement Fixtures Lamp included. Fits existing mounting hood Watts Per Lamp Lamp Voltage Catalog Number Lamp Included ❶ 18 28 18 28 6 VDC 6 VDC 12 VDC 12 VDC AAU1N-186 AAU1N-286 AAU1N-1812 AAU1N-2812 ❶ To order fixtures with guard installed add suffix – G. Reflectors and exit signs are ordered separately. See accessories page. Effective September, 2005 Copyright 2005 PAGE 22 800-621-1506 www.appletonelec.com G2-23 ELS Series Emergency Lighting System: Accessories, Replacement Parts and Technical Data Description Catalog Number Guard AAGU1 Three-Way Exit Sign Epoxy enameled steel — 6”-high red lettering CJEXRN Mounts to fixture units in place of guard. Single Sided Exit Sign Epoxy enameled steel — 6”-high red lettering G AEXR-15R Mounts to fixture units in place of guard. 30° Angle Reflector AARW15AN Standard Dome Reflector AARW15ST Push-to-Test Station Cover with Switch and Pilot Light Switch Only Pilot Light Only EFDCB150J1U1-T-A EFKB-J1U1-TEST SPBB-U1-Q SPLNS-RE-B Lamp, Lamp, Lamp, Lamp, 59620527074 59620527075 59620527076 59620527078 18 28 18 28 W, W, W, W, 6 VDC 6 VDC 12 VDC 12 VDC Technical Data: Operating Temperature Lamp Watts Supply Wire Temp (degrees C) Ambient Temp (degrees C) Class I, Div. 1 & 2 Operating Temperature Class II, Division 1 & 2 (Groups E, F & G) Operating Temperature 18 28 125 125 40 40 T5 T5 T3C T3C Operating temperatures are with and without reflectors and guards “T” numbers represent the maximum surface temperature for Class I, Div. 1 locations and the maximum surface temperature under dust blanket for Class II, Div. 1 locations. “T” Number Temp. Range (°C) T1 350 325 T2 T2A T2B T2C T2D T3 T3A 351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180 T3B T3C T4 T4A T5 T6 161-165 136-160 121-135 101-120 86-100 85 NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per NEC 500-2(c). Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 23 G2-24 ELS Series Emergency Lighting System: Weights and Dimensions Weights Weight (lbs.) Catalog Number Weight (lbs.) ELS06, ELS012 AP1050-186-DM AP1050-186 AC1050-186 ALB1050-186 ASB1050-186 EFDCB150J1U1-T-A 52 11 9 12.5 16.6 12.5 4 Catalog Number AAU1N-186 AAGU1 AEXR-15R CJEXRN AARW15AN AARW15ST 7.6 0.4 5 5 2.1 2.1 Dimensions (In Inches) 14.69 13.50 G 14.38 .38 1.31 10.75 12.00 14.12 12.25 11.63 12.25 13.13 Battery Enclosure 7.06 Direct Mount fixture 4.75 2.63 2.69 5.38 3.38 Pendant Mount .38 45° 13.56 13.13 13.75 12.94 13.13 13.75 9.13 12.38 7.06 Long Bracket Mount Ceiling Mount Short Bracket Mount 3.00 6.88 11.75 5.41 7.63 .00 10 8.50 AEXR-15R EFDCB150J1JU1-T-A 33.50 AARW15AN 13.00 9.25 4.38 28.67 12.00 14.00 ELS with 2 direct mounted fixtures Effective September, 2005 Copyright 2005 PAGE 24 CJEXRN AARW15ST 800-621-1506 www.appletonelec.com Code•Master™ Strobe and Beacon Factory Sealed Lighting Fixtures: Explosionproof, Dust-Ignitionproof G2-25 Applications Code•Master Explosionproof Strobe and Beacon Fixtures are designed to provide safe operation in the presence of hazardous gases, vapors, or dusts, defined by the National Electrical Code as Class I, Groups C and D, and Class II, Groups E, F and G. For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. In areas where audible signals cannot be heard. To warn of unsafe conditions and other communication needs. -25°C minimum operating temperature. • • G • • • Features • • • • • • Fixtures operate safely in high ambient temperatures. Available for fire alarm hearing impaired. Strobe 65 flashes per minute. Beacon 75 rotations per minute. Fixtures are complete with lamp. Patented “wireless” design. Threading of fixture unit onto mounting hood makes electrical connection. The only wiring required is attaching two wires to connection block in mounting hood. Connection block is easily wired: (a) loosen two screws, (b) make wire connections, (c) re-position connection block. Safe, easy servicing without disconnecting any wiring. “Wireless” fixture unit threads off mounting hood for convenient servicing or for immediate replacement with a “stand-by” unit. Acme double-lead threads speed installation and fixture removal from mounting hood only half as many turns are required as for single-lead threads. The threads do not stick or gall, eliminating problems often encountered with single-lead threads during fixture unit removal. All threaded joints are flame-tight. Lens available in five colors: Red, Amber, Blue, Green and Clear. (Factory installed). Factory sealed. External seals not required. Heat and impact resistant globes have smooth dust-resistant exterior. Fixtures are suitable for mounting in any position including globe up or globe down utilizing pendant, ceiling or wall bracket type mounts. Fixtures shown with optional guard. • • • • • • • Effective September, 2005 Copyright 2005 • • Superior corrosion-resistance, with epoxy powder coat finish. Fixture is suitable for mounting globe up or globe down utilizing pendant, ceiling or wall bracket type mounts. Optional guards protect globes from damage. Secured to fixture with three stainless steel screws. • Standard Materials Fixture housing and guards: copperfree aluminum (less than 4/10 of 1% maximum copper content). Mounting hoods: copper-free aluminum (less than 4/10 of 1%). Globes: Prismatic Glass. • • • Standard Finishes Fixture housing, guards and mounting hoods: Epoxy power coat finish, electrostatically applied for complete, uniform corrosion protection. • Compliances • UL and cUL Listed. • Class I, Div. 1 and 2, Groups C and D. • Class I, Div. 2, Groups A, B, C and D. • Class II, Div. 1 and 2, Groups E, F, and G. • Class III. • Type 3R and 4X • Marine Outside Type (Saltwater). • UL 1203. • UL 1638 Visual Signaling Appliances. • UL 1971 Visual Signaling Equipment has been investigated for fire protective signaling services to alert hearing impaired persons. This signaling equipment is intended to be used in conjunction with Listed compatible units and devices. Visual signaling equipment Listed in this category is intended to be used in the “Public Operating Mode” as defined in NFPA 72. 800-621-1506 www.appletonelec.com PAGE 25 G2-26 Code•Master™ Strobe and Beacon Factory Sealed Lighting Fixtures: Explosionproof, Dust-Ignitionproof Ordering Information: Order using catalog numbering guide below or select catalog number from pages G2-27 through G2-30. CATALOG NUMBERING GUIDE FOR CODE-MASTER STROBE AND BEACON LUMINAIRES CS S P 75 HUB SIZE: 75 - 3/4” MOUNTING HOOD: SERIES: G CS - Code-Master Signal TYPE: 120AC P - PENDANT B - WALL BRACKET C - CEILING S - Strobe B - Beacon CL P GLOBE: CL - Clear AM - Amber** BL - Blue** GR - Green** RE - Red** VOLTAGE CURRENT: 120AC - 120VAC 240AC - 240VAC 250DC - 250VDC 1248DC - 12-48VDC† 2030DC - 20-30VDC* 2428DC - 24-28VDC***†† 24DC - 24VDC*** OPTIONS: P - Hearing Impaired (UL1971) (Strobe Only) G - Guard * UL1971 Strobe Only ** Not for use with UL1971 Strobe *** Diode Polarized (Current limiter supplied as standard). †Strobe Only ††Beacon Only Technical Data: Thermal Suitability of Code-Master Strobe and Beacon Fixture. Operating Temperatures Class I, Div. 1 and 2 Groups C & D Strobe Beacon Ambient Temp. 40°C 55°C 65°C T6 T6 T6 Class I, Div. 2 Groups A & B Strobe Beacon T6 T5 T5 T2B T2B T2A Class II, Div. 1 & 2 Class III Strobe Beacon 450°C 450°C 450°C T4A T4A T4 T4A T4A T4 Operating Temperatures: Represent the Maximum Internal Temperature for Class I, Div. 2 Locations and Maximum Surface Temperature for Class I, Div. 1 Locations, and Maximum Surface Temperature Under Dust Blanket for Class II, Div. 1. “T’ Number Temp Range (°C) T1 350 325 T2 351-450 326-350 301-325 281-300 T2A TB T2C 261-280 231-260 216-230 T2D T3 201-215 181-200 T3A T3B T3 T4 T4A T5 166-180 161-165 136-160 121-135 101-120 86-100 T6 85 NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per NEC 500-5(e, f ). Effective September, 2005 Copyright 2005 PAGE 26 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2, Groups C,D Class I, Div. 2, Groups A,B Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3R, 4X UL and cUL Listed Standards UL 1638 and UL1203 Suitable for Wet Locations Marine Outside Type (Saltwater) Code•Master™ Strobe and Beacon Factory Sealed Lighting Fixtures: Explosionproof, Dust-Ignitionproof Pendant Strobe One Hub 3/4” NPT Rigid Conduit. Beacon G2-27 Catalog Number* † CSSP75120ACCL CSSP75240ACCL CSSP75250DCCL CSSP751248DCCL CSSP7524DCCL** 120VAC 240VAC 24-28VDC CSBP75120ACCL CSBP75240ACCL CSBP752428DCCL** 120VAC 240VAC 250VDC 12-48VDC 24VDC CSSC75120ACCL CSSC75240ACCL CSSC75250DCCL CSSC751248DCCL CSSC7524DCCL** 120VAC 240VAC 24-28VDC CSBC75120ACCL CSBC75240ACCL CSBC752428DCCL** 120VAC 240VAC 250VDC 12-48VDC 24VDC CSSB75120ACCL CSSB75240ACCL CSSB75250DCCL CSSB751248DCCL CSSB7524DCCL** 120VAC 240VAC 24-28VDC CSBB75120ACCL CSBB75240ACCL CSBB752428DCCL** G Volts 120VAC 240VAC 250VDC 12-48VDC 24VDC Ceiling Strobe Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs Beacon Wall Bracket Strobe Rigid Conduit Four Hubs 3/4” NPT Three Close-Up Plugs Beacon * Catalog numbers shown are supplied with clear lens. Add G suffix for optional Guard. ** Diode Polarized (Current limiter supplied as standard). †To order colored lens replace last digits of catalog number CL with AM for Amber, BL for Blue, GR for Green, RE for Red. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 27 G2-28 Code•Master™ Strobe and Beacon Factory Sealed Lighting Fixtures: Mounting Hoods, Fixture Units, Weights Mounting Hoods: Type Mounting Hub Size (In.) Hood Weight Catalog Number Pendant One Hub Rigid Conduit 3/4 2 lbs. CAP75 Ceiling Four Hubs Three Close-Up Plugs Rigid Conduit 3/4 4 lbs. CAC75 3/4 6 lbs. CALB75 Volts Unit Weight Catalog Number*† G Class I, Div. 1 and 2, Groups C,D Class I, Div. 2, Groups A,B Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3R, 4X UL and cUL Listed Standards UL 1638 and UL1203 Suitable for Wet Locations Marine Outside Type (Saltwater) Bracket Four Hubs Three Close-Up Plugs Rigid Conduit Fixture Unit Only: (not including mounting hood) Strobe 120VAC 240VAC 250VDC 12-48VDC 24VDC 10 10 10 10 10 Beacon 120VAC 240VAC 24-28VDC 10 lbs. 10 oz. 10 lbs. 10 oz. 10 lbs. 10 oz. lbs. lbs. lbs. lbs. lbs. 3 3 3 3 3 oz. oz. oz. oz. oz. CSST120ACCL CSST240ACCL CSST250DCCL CSST1248DCCL CSST24PDCCL** CSB120ACCL CSB240ACCL CSB2428PDCCL** † To order colored lens replace last digits of catalog number CL with AM for Amber, BL for Blue, GR for Green, RE for Red. Effective September, 2005 Copyright 2005 PAGE 28 800-621-1506 www.appletonelec.com Class I, Div. 1 and 2, Groups C,D Class I, Div. 2, Groups A,B Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 3R, 4X UL and cUL Listed Standards UL 1638 and UL1203 Suitable for Wet Locations Marine Outside Type (Saltwater) Code•Master™ Strobe and Beacon Factory Sealed Lighting Fixtures: Explosionproof, Dust-Ignitionproof G2-29 Strobes For The Hearing Impaired Strobes: Volts Hearing Impaired Catalog Number UL1971 - Hearing Impaired* Pendant One Hub 3/4” NPT Rigid Conduit 20-30VDC CSSP752030DCCLP Ceiling Rigid Conduit, Four Hubs 3/4” NPT, Three Close-Up Plugs 20-30VDC CSSC752030DCCLP Bracket Rigid Conduit, Four Hubs 3/4” NPT, Three Close-Up Plugs 20-30VDC CSSB752030DCCLP G Mounting Hoods: Type Mounting Type Mounting Hub Size (Inches) Hearing Impaired Catalog Number Pendant One Hub Rigid Conduit 3/4 CAP75-1971 Ceiling Four Hubs Three Close-up Plugs Rigid Conduit 3/4 CAC75-1971 Bracket Four Hubs Three Close-up Plugs 3/4 CALB75-1971 Volts Hearing Impaired Catalog Number 20-30VDC CSST2030PDCCL Fixture Unit Only: (less mounting hood) Connection Block: (replacement part) Hearing Impaired Catalog Number For Hearing Impaired Code-Master Fixtures VPT-7P * Only clear globes are available for UL1971 Applications. Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 29 G2-30 Code•Master™ Strobe and Beacon Factory Sealed Lighting Fixtures: Accessories, Replacement Parts, Weights Description Weight Catalog Number 1.0 lbs. CJGU-15 0.5 lbs. VPT-7 Optional Aluminum Guard Copper-Free Aluminum. G Replacement Connection Block For Non-Hearing Impaired Code-Master Fixtures. Replacement Lamps For Strobe and Beacon Code-Master Fixtures. 125-240AC S865 Fixture Type Lamp Type Voltage Wattage Base Type Catalog Number Beacon Halogen 120VAC 40W DBL Bayonet Q4OA9-120AC Beacon Halogen 24-28VDC 18W DBL Bayonet Q20A-24VDC Beacon Incand. 240VAC 25W DBL Bayonet 125-240AC Strobe Xenon All -------- Octal Socket S865 Q4OA9-120AC Q20A-24VDC Effective September, 2005 Copyright 2005 PAGE 30 800-621-1506 www.appletonelec.com G2-31 Code•Master™ Strobe and Beacon Factory Sealed Lighting Fixtures: Family Tree and Dimensions Pendant One Hub — 3/4” NPT CAP75 CAP75-1971 Ceiling Four Hubs Three Close-Up Plugs 3/4” NPT CAC75 CAC75-1971 Bracket Four Hubs Three Close-Up Plugs 3/4” NPT CALB75 CALB75-1971 Fixture Unit With Globe 120AC 240AC 12-48DC 250DC 20-30DC 24DC Beacon 120AC CSB120ACCL 240AC CSB240ACCL 24-28DC CSB2428PDCCL** G CSST120ACCL CSST240ACCL CSST1248DCCL CSST250DCCL CSST2030PDCCL* CSST24PDCCL** Strobe Optional Aluminum Guard CJGU-15 * UL1971 (See page G2-25). ** Diode Polarized (Current limiter supplied as standard). Dimensions: Wall Bracket Ceiling Pendant Hub For 3/4” NPT Hub for 3/4” NPT Conduit. 2” Wiring access cover both sides. 4.50” 3.75” Hub for 3/4” NPT Conduit Four Sides .94” 5.95” 13.88” 13.15” 4” 4.92” 13.53” 12.38” 13.38” 13.00” 13.75” 7.80” 7.80” Effective September, 2005 Copyright 2005 7.80” 800-621-1506 www.appletonelec.com PAGE 31 G2-32 UL and cUL Listed Class I, Div. 1, Groups C,D Class I, Zone 1, Group IIB Class II, Div. 1 and 2, Groups E,F,G Class III UL 844 UL 1598A NEMA 3R and 4X Applications Code•Master Incandescent Explosionproof Fixtures are designed to provide safe operation in the presence of hazardous gases, vapors, or dusts, defined by the National Electrical Code as Class I, Groups C and D, Class I, Zone 1, Group IIB and Class II, Groups E, F and G. For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. For use in chemical and petrochemical plants, such as manufacturers of plastics, paints, and thinners, in refineries, and in other areas where ignitable vapors, dust, moisture and corrosive elements may be present. Suitable for outdoor saltwater locations and for other wet locations. Code•Master™ Incandescent Factory Sealed Lighting Fixtures: Explosionproof, Dust-Ignitionproof For use with threaded metal conduit. • • G • • Features • • Fixtures operate safely in high ambient temperatures. Patented “wireless” design. Threading of fixture unit onto mounting hood makes electrical connection. The only wiring required is attaching two wires to connection block in mounting hood. Connection block is easily wired: (a) loosen two screws, (b) make wire connections, (c) re-position connection block. Safe, easy servicing without disconnecting any wiring. “Wireless” fixture unit threads off mounting hood for convenient servicing or for immediate replacement with a “stand-by” unit. Acme double-lead threads speed installation and fixture removal from mounting hood only half as many turns are required as for single-lead threads. The threads do not stick or gall, eliminating problems often encountered with single-lead threads during fixture unit removal. Strategic location of lamp socket, in combination with interior prism design of the glass globe, provides optimum light distribution and control. Heat-and impact-resistant globes have smooth dust-resistant exterior. Superior corrosion-resistance, with epoxy powder coat finish. • • • • • • Effective January, 2007 Copyright 2007 PAGE 32 • Porcelain socket with nickel plated phosphor bronze screw shell. Assures long trouble-free operation in high ambient areas. Choice of mountings: pendant, ceiling, bracket and stanchion. Fiberglass reinforced polyester reflectors, in standard dome, or 30° angle styles, are ideal in installations where luminaire is subject to exceptionally severe corrosive atmospheres. All threaded joints are flame-tight. Heat and impact resistant globes have smooth dust-resistant exterior. Superior corrosion-resistance, with epoxy powder coat finish. Optional guards protect globes from damage. Secured to fixture with three stainless steel screws. • • • • • • Standard Materials Fixture housing and guards: copperfree aluminum (less than 4/10 of 1% maximum copper content). Mounting hoods: copper-free aluminum (less than 4/10 of 1%). • Globes: Prismatic Glass. • Reflectors: fiberglass reinforced polyester. Standard Finishes • Fixture housing, guards and mount- ing hoods: Epoxy power coat finish, electrostatically applied for complete, uniform corrosion protection. Compliances UL and cUL Listed. Class I, Div. 1, Groups C and D. Class I, Zone 1, Group IIB. Class II, Div. 1 and 2, Groups E, F, and G. Class III. UL 844 Hazardous Locations UL 1598A Marine Type Electric Fixtures Outside Type (Salt Water) Outdoor Wet Locations NEMA 3R and 4X • • • • • • • • • • 800-621-1506 www.appletonelec.com Code•Master™ Incandescent Factory Sealed Lighting Fixtures: Explosionproof, Dust-Ignitionproof G2-33 For use with threaded metal conduit. Ordering Information: Order using catalog numbering guide below or select catalog number from pages G2-34. CATALOG NUMBERING GUIDE FOR CODE-MASTER INCANDESCENT LUMINAIRES CI P 30 75 G SERIES: MOUNTING HOOD: WATTAGE: HUB SIZE: OPTIONS: CI – Code•Master Incandescent 30 – 100W A21 200W A23 300W PS25 75 – 3/4” 100 – 1” 150 – 1-1/4” or 1-1/2” G – Guard Blank – No Guard G P – Pendant B – Wall Bracket C – Ceiling S – Stanchion Technical Data: Thermal Suitability of Code-Master Incandescent Fixture. Lamp Watts (Max.) Use Wire Supply Ambient Temperature Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F & G Incandescent (A21) 100 75°C 40°C T5 T3C Incandescent (A23) 200 75°C 40°C T4 T3C Incandescent (PS25) 300 75°C 40°C T3C T3C Lamp Type “T” Numbers Represent the Maximum External Temperature for Class I, Div. 1 Locations and Maximum Surface Temperature Under Dust Blanket for Class II, Div. 1 Locations. “T” Number T1 350 325 T2 T2A T2 T2C T2D T3 T3A T3B T3 T4 T4A T5 T6 Temp Range (C°) 351450 326350 301325 281300 261280 231260 216230 201215 181200 166180 161165 136160 121135 101120 86100 85 NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per NEC 500-5(e, f ). Effective January, 2007 Copyright 2007 800-621-1506 www.appletonelec.com PAGE 33 G2-34 UL and cUL Listed Class I, Div. 1, Groups C,D Class I, Zone 1, Group IIB Class II, Div. 1 and 2, Groups E,F,G Class III UL 844 UL 1598A NEMA 3R and 4X Code•Master™ Incandescent Factory Sealed Lighting Fixtures: Fixtures, Mounting Hoods For use with threaded metal conduit. Hub Size (In.) Catalog Number * One Hub 3/4 CIP3075 Rigid Conduit. 1 CIP30100 † Rigid Conduit 3/4 CIC3075 Four Hubs 1 CIC30100 † Rigid Conduit 3/4 CIB3075 Four Hubs 1 CIB30100 † 1-1/2 ♦ CIS30150 Pendant Ceiling G Three Close-Up Plugs Wall Bracket Three Close-Up Plugs 25° Stanchion One Hub * Catalog numbers shown are supplied with clear lens. Add suffix G for optional Guard. Mounting Hoods: Type Mounting Hub Size (In.) Hood Weight Catalog Number Pendant 3/4 2 lbs. CAP75 One Hub 1 2 lbs. CAP100 † Rigid Conduit Ceiling 3/4 4 lbs. CAC75 Four Hubs 1 4 lbs. CAC100 † Three Close-Up Plugs Rigid Conduit Bracket 3/4 6 lbs. CALB75 Four Hubs 1 6 lbs. CALB100 † Three Close-Up Plugs Rigid Conduit 25° Stanchion 1-1/4 or 1-1/2 ♦ CAS-150 ♦ One Hub ♦ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer. † 1” Hubs are listed for Group D only. Effective January, 2007 Copyright 2007 PAGE 34 800-621-1506 www.appletonelec.com UL and cUL Listed Class I, Div. 1, Groups C,D Class I, Zone 1, Group IIB Class II, Div. 1 and 2, Groups E,F,G Class III UL 844 UL 1598A NEMA 3R and 4X G2-35 Code•Master™ Incandescent Factory Sealed Lighting Fixtures: Fixture Unit, Accessories, Replacement Parts, Weights For use with threaded metal conduit. Fixture Unit Only: (not including mounting hood) Catalog Number CJNC30I Accessories Description Weight Catalog Number G Optional White Polyester Reflector Standard Dome KR2-ST 2.5 lbs. Optional White Polyester Reflector Angled Reflector 2.5 lbs. KR2-AN 0.5 lbs. CJGU-15 Optional Aluminum Guard Copper-Free Aluminum. Optional Three Way Exit Sign CJEXRN Replacement Connection Block VPT-7 0.5 lbs. Fixture and Accessory Weights Fixture Mounting Hood Effective January, 2007 Copyright 2007 Fixture Weight Reflector Weight Guard Weight 11 lbs. 3 lbs. 1 lb. Pendant Ceiling Bracket Stanchion 2 lbs. 4 lbs. 6 lbs. 2 lbs. 800-621-1506 www.appletonelec.com PAGE 35 G2-36 UL and cUL Listed Class I, Div. 1, Groups C,D Class I, Zone 1, Group IIB Class II, Div. 1 and 2, Groups E,F,G Class III UL 844 UL 1598A NEMA 3R and 4X Pendant One Hub 3/4” NPT CAP75 Code•Master™ Incandescent Factory Sealed Lighting Fixtures: Family Tree, Dimensions For use with threaded metal conduit. Ceiling Four Hubs Three Close-Up Plugs 3/4” NPT CAC75 Bracket Four Hubs Three Close-Up Plugs 3/4” NPT CALB75 25° Stanchion One Hub 1-1/4 or 1-1/2” NPT CAS150 G Code•Master Incandescent Fixture Unit CJNC30I Standard Dome KR2-ST Optional Aluminum Guard CJGU-15 Angle Reflector KR2-AN Optional Three Way Exit Sign CJEXRN Dimensions: Pendant Hub for 3/4” NPT Conduit. Wall Bracket 4.50” Hub For 3/4” NPT 13.88” 2” Wiring access cover both sides. 4.92” 3.75” 12.38” 13.15” 13.75” 7.80” 25° Stanchion 7.80” Hub for 3/4” NPT Conduit Four Sides .94” 25° 5.95” Ceiling 4” 11.93” 13.38” 12.87” 13.00” 11.43” 12.48” 7.80” Effective January, 2007 Copyright 2007 PAGE 36 800-621-1506 www.appletonelec.com G2-37 ® G Effective September, 2005 Copyright 2005 800-621-1506 www.appletonelec.com PAGE 37
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:11:07 09:35:32-06:00 Create Date : 2008:10:14 13:21:09-05:00 Metadata Date : 2008:11:07 09:35:32-06:00 Format : application/pdf Title : G2 1-32 Updated.indd Creator : moleary Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:6fadc51b-8d01-47be-9a53-36ddeca3c738 Instance ID : uuid:bc36a23d-e13c-431e-bec0-d514d9f0c53a Has XFA : No Page Count : 37 Page Layout : OneColumn Author : molearyEXIF Metadata provided by EXIF.tools