G2-1

Incandescent Lighting:
Explosionproof

A-51® Groups C & D

EHL Handlamp

Description

5-11

A-51® Series Lighting Fixtures—
Class I, Groups C and D

2,3

Features

4

Classified Area Suitability, Weights

5,6

Ordering Information

7

Mounting Hoods, Fixture Units, Globes and Guards

8

Reflectors, Colored Globes, and Parts

9

Dimensions

10, 11

Photometrics

12,15

A-51® Series Lighting Fixtures—
Class I, Groups A and B

2,3

Features

12

Ordering Information and Reflectors

13

Mounting Hoods, Fixture Units, Globes, Guards
and Parts

14

Dimensions

15

Photometrics

16

AHL and EHL Portable Handlamps

16

Features

17

Fixtures, Parts and Dimensions

18

EDT Lighting Fixtures and Accessories

19-24

ELS Series Emergency Lighting System

19

Features

20-22

Ordering Information

23

Replacement Parts and Technical Data

24

Weights and Dimensions

25-31

Code-Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures

25

Features

26

Order Information and Technical Data

27-29

Fixtures

30

Optional Guard and Replacement Parts

31

Dimensions

ELS Series

Code•Master™ Strobe

Effective September, 2005
Copyright 2005

G

A-51® Groups A & B

Page

See Section Q for Explosionproof Floodlights.

800-621-1506
www.appletonelec.com
PAGE 1

G2-2

A-51® Incandescent Explosionproof
Lighting Fixtures: Factory Sealed
Suitable for use in Wet Locations.
UNILETS¨ for use with Threaded Metal Conduit.

Applications
A-51 Series Incandescent Class I,
Groups A, B, C and D; Class II, E, F
and G applications (see listings and
area suitability chart).
Ideal for use in chemical and
petrochemical plants and in other
heavy process areas where ignitable
vapors, dust, moisture and corrosive
atmospheres may be present.
Suitable for use in wet locations.
Wide range of wattages — 60 thru
500 watt incandescent lamps.
Choice of units with or without
guard as well as choice of porcelain or
polyester reflectors.
Choice of mountings — pendant,
ceiling, stanchion, long bracket and
short bracket.
Porcelain reflectors for standard
applications and fiberglass reinforced
polyester reflectors for installations
where fixture is subject to exceptionally severe corrosive atmospheres.
High bay reflector for installations
where mounting height from work
plane ranges from 20 to 30 feet.
Class I, Groups A and B fixtures
have special UL approved sintered
metal flame arrester.

•
•

G

•
•
•
•
•

•

Features

• All A-51 fixtures are factory sealed—

no external sealing fittings are required.
New high temp phenolic connection block in mounting hood has
rugged leaf spring contacts—loosen
two screws, rotate and remove for
quick wiring.
Safe, easy servicing or relamping without disconnecting any wiring.
“Wireless” fixture unit easily threads
off mounting hood for convenient
servicing or for immediate exchange
with “stand-by” unit.
All joints are flame tight.

•
•

•

Effective September, 2005
Copyright 2005
PAGE 2

800-621-1506
www.appletonelec.com

A-51® Incandescent Explosionproof
Lighting Fixtures: Factory Sealed

G2-3

Suitable for use in Wet Locations.
UNILETS® for use with Threaded Metal Conduit.

• Specially formulated two coat baked

• Class

•

•
•

epoxy enamel provides superior
protective finish to resist corrosion.
Applied to all mounting hoods, fixture
units and guards.
N ew h i g h t e m p e ra t u r e g l a s s
reinforced phenolic socket block in
fixture unit has collector ring and pin
which automatically makes electrical
contact as fixture unit is threaded onto
mounting hood.
Globes in A-51 fixtures are explosion-proof and heat and impact resisting glass. Prismatic configuration
on globe interior provides light control
while allowing smooth exterior surface
for cleaning.
A-51 fixture units have standardized
threads to fit all A-51 and mounting
hoods.
All fixtures have Alzak® aluminum
inner reflector for increased lumen
efficiency.
A-51 fixture guards are of rugged
copper-free aluminum construction and
double epoxy coated—provide protection to globe. Easily mounts to globe
ring with 3 screws.

I,* Div. 1 and 2, Groups
A,B,C,D. Class II,* Div. 1 and 2, Groups
E,F,G.
*Some models.
Suitable for use in wet locations.
Appleton malleable iron products
conform to ASTM A47-77, Grade
32510, which has the following properties: tensile strength, 50,000 psi; yield,
32,000 psi; and elongation, 10%.

• Appleton

a l u m i nu m p r o d u c t s
are produced from a high strength
copper-free (4/10 of 1% max.) alloy.
Product Cross Reference
See general introduction to catalog
for information on fixture selection. For
HID fixtures with integral ballasts, see
Code•Master Series in catalog section
G1. Fluorescent fixtures are in section
F3 and G3.

•

•

G

•
•

Porcelain

•

Standard Materials
Fixtures and guards: copper-free
aluminum (4/10 of 1%).
Pendant mounting hoods: copperfree aluminum (4/10 of 1%).
Ceiling and bracket mounting hoods:
malleable iron with aluminum adapters.
Reflectors: porcelain enameled
steel, Alzak aluminum or fiberglass
reinforced polyester.

•
•
•
•

Standard Finishes
guards and mounting
hoods: two coat epoxy-clad finish.
Epoxy powder coat finish, electrostatically applied for complete, uniform surface protection.
Steel reflectors: white porcelain
enamel.
Polyester and Alzak aluminum
reflectors: natural finish.

• Fixtures,
•
•

Compliances
UL Listed.
UL 1598 and 844.

•
•

Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 3

G2-4

A-51® Incandescent Fixtures
Classified Area Suitability and Weights

Class I Div. 1 and Div. 2 Groups C and D
Lamp
Watts

Without Reflectors

Standard Dome

30˚ Angle

High Bay

Supply
Wire

AAU1N

100W A19
100W A21

T5
T5

T5
T5

T5
T5

_
_

125°C
125°C

AAU15N

150W
200W
200W
300W

A23
A25
PS25
PS25

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3A

T3C
T3C
T3C
T3A (D)

_
_
_
_

125°C
125°C
125°C
125°C

AAU2NS

200W
200W
300W
300W

PS25
PS30
PS25
PS30

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

_
_
_
_

110°C
110°C
110°C
110°C

AAU5NS

500W PS35
500W PS40

T3C
T3C

T3C
T3C

T3C
T3C

_
_

135°C
135°C

G

Fixture
Unit

Class I Div. 1 and Div. 2 Groups A, B, C and D
AAUA15

150W
150W
200W
200W

A23
A25
A25
PS25

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

_
_
_
_

110°C
110°C
110°C
110°C

AAUA2

200W
200W
300W
300W

PS25
PS30
PS25
PS30

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

_
_
_
_

110°C
110°C
110°C
110°C

Class II Div. 1 and Div. 2 Groups E, F and G
AAU1N

100W A19
100W A21

T3C
T3C

T3C
T3C

T3C
T3C

_
_

125°C
125°C

AAU15N

150W
200W
200W
300W

A23
A25
PS25
PS25

T3C
T3C
T3
T3

T3C
T3C
T3

T3C
T3C
T3

_
_
_
_

125°C
125°C
125°C
125°C

AAU2NS

200W
200W
300W
300W

PS25
PS30
PS25
PS30

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

T3C
T3C
T3A (EF)
T3A (EF)

_
_
_
_

110°C
110°C
110°C
110°C

AAU5NS

500W PS35
500W PS40

T3C
T3C

T3C
T3C

T3C
T3C

_
_

135°C
135°C

Group A Pendant Mount only. NOTE: Ambient suitability of these incandescent fixtures: 40° C

Weights
Fixture Units
Cat. No. Wt., Lbs.

Mounting Hoods
Cat. No.
Wt., Lbs.

Guards
Cat. No.

AAU-1N
AAU-15N
AAU-2NS
AAU-5NS
AAUA-15
AAUA-2

Pendant
Ceiling
Stanchion
Long Bracket
Short Bracket

AAGU-1
AAGU-2
AAGU-5
AAGUA-15

7.6
7.6
10.7
20.3
15.0
18.0

Effective September, 2005
Copyright 2005
PAGE 4

1.3
4.8
1.6
8.9
4.8

Wt., Lbs.
.4
.8
1.9
.5

Standard Reflectors
Cat. No.
Wt., Lbs.

30˚ Angle Reflectors
Cat. No.
Wt., Lbs.

High Bay Reflectors
Cat. No.
Wt., Lbs.

AARP-2ST
AARW-15ST
AARW-2ST
AARW-5ST
AARW-15ST

AARP-2AN
AARW-15AN
AARW-2AN
AARW-5AN
AARW-15AN

AARE-2HB
AARE-5HB

2.8
2.1
2.9
4.3
2.1

3.3
2.1
2.4
7.0
2.1

2.9
3.9

800-621-1506
www.appletonelec.com

Class I, Div. 1 and 2
Groups C,D
Class II, Div. 1 and 2
Groups E,F,G*
Class III

A-51® Incandescent Explosionproof
Lighting Fixtures: Factory Sealed

G2-5

Suitable for use in Wet Locations.

UL 1598, UL 844
Hub Size
(Inches)

Catalog
Number

60-100 Watt (AAU-1N)
A-21

1/2
3/4
1

AP1050
AP1075
AP10100

150-300 Watt (AAU-15N)
A-23 PS-25

1/2
3/4
1

AP1550
AP1575
AP15100

200-300 Watt (AAU-2NS)
PS-30

1/2
3/4
1

AP2050
AP2075
AP20100

300-500 Watt (AAU-5NS)
PS-35

1/2
3/4
1

AP5050
AP5075
AP50100

60-100 Watt (AAU-1N)
A-21

1/2
3/4
1

AC1050
AC1075
AC10100

150-300 Watt (AAU-15N)
A-23 PS-25

1/2
3/4
1

AC1550
AC1575
AC15100

200-300 Watt (AAU-2NS)
PS-30

1/2
3/4
1

AC2050
AC2075
AC20100

300-500 Watt (AAU-5NS)
PS-35

1/2
3/4
1

AC5050
AC5075
AC50100

60-100 Watt (AAU-1N)
A-21

1-1/2◆

AN10150

150-300 Watt (AAU-15N)
A-23 PS-25

1-1/2◆

AN15150

200-300 Watt (AAU-2NS)
PS-30

1-1/2◆

AN20150

300-500 Watt (AAU-5NS)
PS-35

1-1/2◆

AN50150

Type

Pendant
One hub, rigid or flexible mounting.

G

Ceiling
Four hubs and three close-up plugs.

25° Stanchion (Not UL Listed)
One hub

*For specific classified area suitability of each fixture listed, see table on page G2-4. ◆1-1/2” tapped hub furnished with a 1-1/2” to 1-1/4” reducer.
Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 5

G2-6

Class I, Div. 1 and 2
Groups C,D
Class II, Div. 1 and 2
Groups E,F,G*
Class III

A-51® Incandescent Explosionproof
Lighting Fixtures: Factory Sealed
Suitable for use in Wet Locations.

UL 1598, UL 844
Hub Size
(Inches)

Catalog
Number

60-100 Watt (AAU-1N)
A-21

1/2
3/4
1

ALB1050
ALB1075
ALB10100

150-300 Watt (AAU-15N)
A-23 PS-25

1/2
3/4
1

ALB1550
ALB1575
ALB15100

200-300 Watt (AAU-2NS)
PS-30

1/2
3/4
1

ALB2050
ALB2075
ALB20100

300-500 Watt (AAU-5NS)
PS-35

1/2
3/4
1

ALB5050
ALB5075
ALB50100

60-100 Watt (AAU-1N)
A-21

1/2
3/4

ASB1050
ASB1075

150-300 Watt (AAU-15N)
A-23 PS-25

1/2
3/4

ASB1550
ASB1575

200-300 Watt (AAU-2NS)
PS-30

1/2
3/4

ASB2050
ASB2075

Type

Long Bracket
Four hubs and three close-up plugs

G

15° Short Bracket
Two hubs and one close-up plug

Three-Way Exit Sign
Epoxy enameled steel — 6”-high red lettering

CJEXRN

60-200W (Mounts to AAU-1N or AAU-15N fixture units
in place of guard)

Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering

AEXR-15R

60-200W (Mounts to AAU-1N or AAU-15N fixture units
in place of guard)
(See page G2-24 for dimensions)

Accessories
Add Suffix to Fixture Catalog Number
Guard
Standard Dome Reflector
30˚ Angle Reflector
High Bay Reflector

Suffix
-G
-ST
-AN
-HB

*For specific classified area suitability of each fixture listed, see table on page G2-4.
Effective September, 2005
Copyright 2005
PAGE 6

800-621-1506
www.appletonelec.com

A-51 Incandescent Explosionproof
Lighting Fixtures: Mounting Hoods,
Fixture Units, Globes, Guards
®

G2-7

Copper-Free Aluminum Fixture with Gray Epoxy Finish.
Mounting Hoods in Aluminum and Malleable Iron.*

Type

Hub Size
(Inches)

Catalog
Number

1/2
3/4
1

AAP-50
AAP-75
AAP-100

1/2
3/4
1

AAC-50
AAC-75
AAC-100

1-1/2

AAN-150†

1/2
3/4
1

AALB-50
AALB-75
AALB-100

1/2
3/4

AASB-50
AASB-75

Mounting Hoods*
Pendant
One hub,
rigid or flexible mounting

Ceiling

G

Four hubs
and three
close-up plugs

25° Stanchion (Not UL Listed)
One hub

Long Bracket
Four hubs
and three
close-up plugs

15° Short Bracket
Two hubs and
one close-up plug

Fixture Units
60-100W A-21
150-300W A-23 & PS-25
200-300W PS-30
300-500W PS-35

AAU-1N
AAU-15N
AAU-2NS
AAU-5NS

Prismatic Glass Globes
60-100W (AAU-1N)
150-300W (AAU-15N)
200-300W (AAU-2NS)
300-500W (AAU-5NS)

AAGL-1PR
AAGL-1PR
AAGL-2PR
AAGL-5PR

Aluminum Guards
60-100W (AAU-1N)
150-300W (AAU-15N)
200-300W (AAU-2NS)
300-500W (AAU-5NS)

AAGU-1
AAGU-1
AAGU-2
AAGU-5

†1-1/2” Tapped hub furnished with a 1-1/2” to 1-1/4” reducer. * Pendant and stanchion mounting hoods are copper-free aluminum. Ceiling and
bracket types are malleable iron with aluminum adapters.
Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 7

G2-8

A-51® Incandescent Explosionproof
Lighting Fixtures:
Reflectors, Colored Globes, Parts
Porcelain, Alzak Aluminum or Polyester Reflectors.
Fixture Size

Catalog Number

Porcelain and Polyester
Reflectors

G

Standard Dome
(Not for use with short brackets)

Porcelain

60-100W (AAU-1N)
150-300W (AAU-15N)
200-300W (AAU-2NS)
300-500W (AAU-5NS)

AARW-15ST
AARW-15ST
AARW-2ST
AARW-5ST

30˚ Angle
60-100W (AAU-1N)
150-300W (AAU-15N)
200-300W (AAU-2NS)
300-500W (AAU-5NS)

AARW-15AN
AARW-15AN
AARW-2AN
AARW-5AN

Polyester

AARP-2ST

AARP-2AN

Alzak Aluminum Reflectors
High Bay
200-300W (AAU-2NS)
300-500W (AAU-5NS)

AARE-2HB
AARE-5HB

Colored Glass Globes
Amber
60-100W (AAU-1N)
150-300W (AAU-15N)
200-300W (AAU-2NS)
Green
60-100W (AAU-1N)
150-300W (AAU-15N)
200-300W (AAU-2NS)
Red
60-100W (AAU-1N)
150-300W (AAU-15N)
200-300W (AAU-2NS)

AAGL-1A
AAGL-1A
AAGL-2A
AAGL-1G
AAGL-1G
AAGL-2G
AAGL-1R
AAGL-1R
AAGL-2R

Replacement Socket
60-100W (AAU-1N)—Medium Base
150-300W (AAU-15N)—Medium Base
200-300W (AAU-2NS)—Medium Base
300-500W (AAU-5NS)—Mogul Base

AASP-11
AASP-22
AASP-22
AASP-44

Connection Block
60-500W. Fits A-51
Mounting Hoods

VPT-7

Globe Gaskets—Fiber
and Aluminum
Requires one of each
60-300W (AAU-1N and AAU-15N)
200-300W (AAU-2NS)
300-500W (AAU-NS)
Effective September, 2005
Copyright 2005
PAGE 8

Fiber
AASP-15V
AASP-2V
AASP-5V

Aluminum
AASP-15A
AASP-2A
AASP-5A
800-621-1506
www.appletonelec.com

G2-9

Dimensions: A-51® Incandescent
Lighting Fixtures
A-51 Lighting Fixtures

Stanchion
B

C

A

Ceiling

B

C

A

Long Bracket

B

C

A

B

C

Short Bracket
A

B

C

Dimensions in Inches
60-100

11.47

10.85

11.50

12.25

11.63

7.06

13.75

13.13

7.06

13.75

13.13

12.38

13.56

12.94

9.13

150-300

11.47

10.85

11.50

12.25

11.63

7.06

13.75

13.13

7.06

13.75

13.13

12.38

13.56

12.94

9.13

200-300

13.07

12.38

12.71

13.94

13.25

8.81

15.44

14.75

8.81

15.50

14.75

13.25

15.19

14.50 10.13

300-500

15.09

14.34

14.64

16.00

15.25

12.13

17.50

17.75

12.13

17.50

16.75

14.88

17.25

16.50 11.94

Dimensions in Centimeters
60-100

29.1

27.6

29.2

31.1

29.5

17.9

34.9

33.3

17.9

34.9

33.3

31.4

34.4

32.9

23.2

150-300

29.1

27.6

29.2

31.1

29.5

17.9

34.9

33.3

17.9

34.9

33.3

31.4

34.4

32.9

23.2

200-300

33.2

31.4

32.3

35.4

33.7

22.4

39.2

37.5

22.4

39.4

37.5

33.7

38.6

36.8

25.7

300-500

38.3

36.4

37.2

40.6

38.7

30.8

44.5

45.1

30.8

44.5

42.5

37.8

43.8

41.9

30.3

◆For dimensions of fixture unit only, subtract pendant hood dimension 1.31” (3.3cm) from dimensions A and B as listed.

A-51 Reflectors*

Size (Watts)

A

B

A

B

A

B

Dimensions in Inches
60-100

12.00

4.50

10.00

7.63

—

—

150-200

14.00

4.38

10.00

7.63

—

—

200-300

16.00

5.19

12.00

7.88

12.00

6.06

300-500

20.00

6.84

18.00

13.13

18.00

9.13

Dimensions in Centimeters
60-100

30.5

11.4

25.4

19.4

—

150-200

35.6

11.1

25.4

19.4

—

—
—

200-300

40.6

13.2

30.5

20.0

30.5

15.4

300-500

50.8

17.4

45.7

33.3

45.7

23.2

*Dimensions illustrated are for porcelain steel (dome and angle) and etched Alzak aluminum (high bay). Overall dimensions for fiberglass
reinforced polyester reflectors are: standard dome—16-1/2” dia., 6” high; 30° Angle—14-3/8” dia., 10” high.
Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 9

G

Size (Watts) A

Pendant◆

G2-10

Photometric Data:
A-51® Incandescent Explosionproof
Lighting Fixtures
Class I, Groups C and D Fixtures.

A-51 Incandescent
Fixture without Reflector
Spacing to Mtg.
Ht. Ratio 1.25:1
Guard .877

Effective Floor Cavity Reflectance (Rfc) is 20%
80

% Ceiling Rcc

ROOM CAVITY RATIOS

% Walls

Rw

50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .735 .690 .651 .695 .655 .618 .622 .590 .561 .554 .530 .506 .493 .473 .454 .422
2 .621 .558 .503 .588 .530 .481 .525 .478 .437 .467 .430 .396 .413 .384 .357 .327
3 .540 .468 .411 .512 .446 .394 .457 .404 .359 .406 .363 .327 .360 .325 .294 .267
4 .474 .400 .342 .450 .381 .328 .402 .346 .301 .359 .312 .274 .318 .280 .248 .223
5 .415 .341 .284 .394 .325 .272 .354 .295 .251 .316 .266 .229 .280 .240 .207 .184
6 .372 .297 .245 .352 .284 .233 .316 .258 .215 .283 .234 .197 .252 .210 .178 .157
7 .334 .262 .213 .317 .249 .203 .285 .227 .187 .255 .207 .170 .228 .187 .155 .136
8 .300 .231 .182 .285 .221 .175 .256 .202 .162 .231 .183 .148 .206 .165 .135 .117
9 .271 .204 .157 .258 .195 .152 .233 .178 .140 .209 .162 .128 .187 .146 .117 .100
10 .246 .181 .139 .234 .175 .135 .212 .160 .124 .191 .145 .113 .172 .132 .102 .087

A-51 Incandescent
Fixture with
Standard Dome
Reflector
Spacing to Mtg.
Ht. Ratio 1.25:1
Guard .890

Effective Floor Cavity Reflectance (Rfc) is 20%
80

% Ceiling Rcc
% Walls

ROOM CAVITY RATIOS

G

Coefficients of Utilization: Zonal Cavity Method
Photometric data shown here is based on a
200 watt type PS-30 lamp and is representative of the performance for all A-51 incandescent fixtures using 60 watt to 500 watt lamps.
For candlepower values of fixtures with other
lamps, use the following multipliers: 60 watt
A-19—.23; 100 watt A-19—.47; 150 watt
A-21—.75; 200 watt A-23—1.07; 200 watt
A-25—1.02; 200 watt PS-25—1.03: 300
watt PS-25—1.70; 300 watt PS-30—1.63;
300 watt PS-35—1.55; 500 watt PS-35—
2.95; 500 watt PS-40—2.69. To determine
candlepower values of fixtures with a guard,
multiply by value shown with each curve.

Effective September, 2005
Copyright 2005
PAGE 10

Rw

50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .757 .727 .700 .740 .713 .689 .709 .686 .667 .681 .663 .646 .656 .641 .627 .612
2 .660 .613 .572 .647 .603 .567 .621 .585 .552 .598 .568 .540 .577 .551 .528 .512
3 .580 .524 .478 .570 .516 .475 .549 .504 .466 .529 .490 .458 .511 .478 .449 .434
4 .514 .452 .403 .504 .446 .400 .486 .436 .395 .469 .425 .390 .454 .415 .384 .368
5 .451 .385 .336 .442 .380 .334 .427 .372 .332 .413 .364 .327 .399 .357 .323 .308
6 .402 .336 .291 .394 .333 .286 .381 .326 .285 .369 .319 .282 .358 .313 .279 .264
7 .361 .296 .254 .355 .293 .250 .343 .286 .247 .332 .282 .245 .323 .278 .243 .229
8 .323 .261 .216 .318 .258 .216 .308 .254 .215 .299 .249 .213 .290 .245 .211 .197
9 .291 .230 .187 .287 .227 .187 .278 .223 .186 .269 .219 .184 .262 .216 .182 .169
10 .264 .204 .166 .259 .204 .166 .253 .200 .164 .245 .197 .162 .240 .194 .161 .149

800-621-1506
www.appletonelec.com

Photometric Data:
A-51® Incandescent Explosionproof
Lighting Fixtures

G2-11

Class I, Groups C and D Fixtures.
Coefficients of Utilization: Zonal Cavity Method
Photometric data shown here is based on a
200 watt type PS-30 lamp and is representative of the performance for all A-51 incandescent fixtures using 60 watt to 500 watt lamps.
For candlepower values of fixtures with other
lamps, use the following multipliers: 60 watt
A-19—.23; 100 watt A-19—.47; 150 watt
A-21—.75; 200 watt A-23—1.07; 200 watt
A-25—1.02; 200 watt PS-25—1.03: 300
watt PS-25—1.70; 300 watt PS-30—1.63;
300 watt PS-35—1.55; 500 watt PS-35—
2.95; 500 watt PS-40—2.69. To determine
candlepower values of fixtures with a guard,
multiply by value shown with each curve.

A-51 Incandescent
Fixture with
High Bay Reflector
Spacing to Mtg.
Ht. Ratio 1.40:1
Guard .865

G

Effective Floor Cavity Reflectance (Rfc) is 20%
80

% Ceiling Rcc

ROOM CAVITY RATIOS

% Walls

Rw

50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .686 .644 .645 .671 .651 .634 .644 .628 .614 .620 .607 .595 .598 .588 .577 .566
2 .614 .580 .549 .603 .571 .545 .581 .555 .531 .562 .540 .520 .544 .525 .508 .496
3 .550 .508 .473 .542 .501 .470 .524 .490 .461 .507 .478 .454 .492 .467 .446 .434
4 .493 .445 .408 .486 .441 .404 .470 .431 .400 .456 .422 .395 .443 .413 .389 .377
5 .439 .387 .349 .432 .383 .347 .420 .376 .344 .407 .369 .340 .396 .383 .336 .324
6 .393 .340 .304 .387 .338 .300 .376 .331 .298 .366 .326 .296 .356 .320 .293 .281
7 .352 .299 .264 .347 .296 .261 .337 .290 .258 .327 .287 .256 .320 .283 .254 .242
8 .313 .261 .224 .309 .259 .223 .300 .255 .222 .293 .251 .220 .285 .247 .219 .207
9 .280 .228 .191 .276 .225 .191 .268 .222 .190 .261 .219 .189 .254 .216 .187 .176
10 .252 .201 .168 .248 .201 .168 .242 .197 .167 .236 .195 .165 .231 .192 .164 .153

A-51 Incandescent
Fixture with
30˚ Reflector

B—Back
S—Side
F—Front
G—Front W.Guard

Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 11

G2-12

Class I, Div. 1 and 2
Groups A◆,B,C,D
Class II, Div. 1 and 2
Groups E,F,G
Class III
UL 1598, UL 844 Listed

A-51® Incandescent Groups A and B
Explosionproof Lighting Fixtures:
Factory Sealed
Suitable for use in Wet Locations.
Fixture Type and Type

Hub Size (Inches)

Catalog Number

60-200 Watt (AAUA-15)
PS-25

1/2
3/4

AAPA1550
AAPA1575

200-300 Watt (AAUA-2)
PS-30

1/2
3/4

AAPA2050
AAPA2075

60-200 Watt (AAUA-15)
PS-25

1/2
3/4

AACA1550
AACA1575

200-300 Watt (AAUA-2)
PS-30

1/2
3/4

AACA2050
AACA2075

60-200 Watt (AAUA-15)
PS-25

1/2
3/4

AASBA1550
AASBA1575

200-300 Watt (AAUA-2)
PS-30

1/2
3/4

AASBA2050
AASBA2075

Pendant
One hub, rigid or flexible mounting.

Ceiling

G

Four hubs and three close-up plugs.

15˚ Short Bracket
Two hubs and one close-up plug.

Accessories
Add suffix to fixture catalog number
Suffix
Guard
Standard Dome Reflector
30˚ Angle Reflector

-G
-ST
-AN

Porcelain Steel and
Polyester Reflectors
Porcelain

Polyester

Standard Dome
60-200 Watt (AAUA-15)
200-300 Watt (AAUA-2)

AARW-15ST
AARW-2ST

AARP-2ST

30˚ Angle
60-200 Watt (AAUA-15)
200-300 Watt (AAUA-2)

AARW-15AN
AARW-2AN

AARP-2AN

◆ Shaded area indicates pendant mount is suitable for Class I, Group A in addition to other applicable area suitabilities.
For specific classified area suitability of each fixture, see page G2-4.
Effective September, 2005
Copyright 2005
PAGE 12

800-621-1506
www.appletonelec.com

G2-13

A-51® Incandescent Groups A† and B
Explosionproof Lighting Fixtures:
Mounting Hoods, Fixtures and Parts

Mounting Hoods in Aluminum and Malleable Iron.* Copper-Free
Aluminum Fixture with Gray Epoxy Finish.
Type

Hub Size
(Inches)

Catalog Number

1/2
3/4

AAP-50†
AAP-75†

1/2
3/4

AAC-50
AAC-75

1/2
3/4

AASB-50
AASB-75

Mounting Hoods
Pendant
One hub, rigid
or flexible mounting
Ceiling

G

Four hubs and
three close-up
plugs
15˚ Short Bracket
Two hubs and
one close-up
plug

Fixture Units
60-200 Watt
PS-25

AAUA-15

200-300 Watt
PS-30

AAUA-2

Globe and Ring Assembly
60-200 Watt (AAUA-15)

AAGLA-15

200-300 Watt (AAUA-2)

AAGLA-2

Aluminum Guards
60-200 Watt (AAUA-15)

AAGUA-15

200-300 Watt (AAUA-2)

AAGU-2

Medium Base Lamp Socket
60-200 Watt (AAUA-15)

AASPA-15

200-300 Watt (AAUA-2)

AASPA-22

Connection Block
Fits all A-51 and AA-51 mounting hoods
60-300 Watt

VPT-7

† Group A pendant mount only. * Pendant mounting hoods are copper-free aluminum. Ceiling and bracket types are malleable iron with aluminum
adapters.
Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 13

G2-14

Dimensions:
A-51® Groups A and B Incandescent Lighting
Fixtures

G

Ceiling

Pendant

Pendant
Size (Watts)

A

Short Bracket

Ceiling

Short Bracket

B

C

A

B

C

A

B

C

Dimensions in Inches
60-200

13.69

13.13

7.06

16.50

15.94

7.06

15.00

14.44

9.50

200-300

14.75

13.69

8.81

17.56

16.50

8.81

16.00

15.44

10.38

Dimensions in Centimeters
60-200

34.8

33.3

17.9

41.9

40.5

17.9

38.1

36.7

24.1

200-300

37.5

34.8

22.4

44.6

41.9

22.4

40.6

39.2

26.4

Effective September, 2005
Copyright 2005
PAGE 14

800-621-1506
www.appletonelec.com

Photometric Data:
A-51® Incandescent Explosionproof
Lighting Fixtures

G2-15

Class I, Groups A and B Fixtures.

Photometric data shown here is based
on a 200 watt type PS-25 lamp, and is
representative of the performance for
A-51 incandescent fixtures (Groups A and B).
For candlepower values of fixtures with other
lamps, use the following multipliers: 150 watt
(PS-25), .70; 300 watt (PS-25), 1.6. To determine candlepower values of fixtures with
a guard, multiply by value shown with each
curve.

Effective Floor Cavity Reflectance (Rfc) is 20% (No Reflector)
80

% Ceiling Rcc
% Walls

Rw

50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .711 .669 .630 .669 .631 .595 .590 .560 .533 .518 .495 .473 .452 .434 .417 .383
2 .602 .541 .488 .567 .511 .465 .499 .455 .416 .437 .402 .371 .380 .352 .327 .296
3 .519 .449 .393 .488 .424 .374 .430 .379 .336 .375 .335 .300 .325 .292 .264 .236
4 .456 .384 .328 .430 .364 .312 .379 .325 .282 .332 .288 .252 .288 .252 .223 .197
5 .400 .328 .274 .378 .311 .260 .334 .278 .236 .293 .247 .211 .254 .217 .187 .164
6 .357 .285 .234 .336 .270 .221 .297 .242 .200 .261 .215 .180 .227 .188 .159 .138
7 .318 .248 .200 .300 .234 .190 .265 .209 .171 .233 .187 .153 .204 .165 .135 .116
8 .287 .219 .172 .270 .208 .164 .240 .187 .149 .212 .167 .134 .104 .147 .119 .101
9 .260 .194 .150 .246 .185 .143 .218 .166 .130 .192 .148 .117 .168 .131 .103 .087
10 .236 .173 .132 .222 .166 .126 .199 .149 .114 .175 .133 .102 .154 .117 .090 .075

Effective Floor Cavity Reflectance (Rfc) is 20% (Std. Dome Reflector)
80

% Ceiling Rcc

ROOM CAVITY RATIOS

% Walls

Rw

50

30

70
10

50

30

50
10

50

30

30
10

50

30

10
10

50

30

0
10

0

1 .797 .763 .733 .779 .748 .721 .745 .720 .697 .715 .695 .676 .689 .671 .655 .640
2 .687 .633 .586 .673 .622 .581 .645 .603 .566 .620 .585 .553 .597 .567 .541 .524
3 .594 .530 .478 .583 .522 .474 .560 .508 .464 .538 .494 .457 .519 .481 .448 .431
4 .527 .458 .404 .517 .452 .400 .497 .440 .395 .479 .430 .390 .462 .419 .384 .366
5 .466 .393 .340 .456 .388 .337 .440 .379 .335 .424 .371 .330 .410 .364 .326 .310
6 .414 .342 .292 .406 .339 .288 .391 .331 .286 .378 .324 .283 .367 .317 .280 .264
7 .369 .298 .252 .362 .294 .248 .350 .288 .245 .337 .284 .242 .328 .279 .240 .225
8 .333 .265 .217 .327 .262 .216 .316 .257 .215 .307 .252 .213 .297 .248 .211 .196
9 .302 .235 .189 .297 .232 .189 .287 .229 .188 .278 .224 .186 .270 .221 .185 .170
10 .273 .209 .167 .268 .209 .167 .261 .204 .166 .253 .201 .163 .247 .198 .162 .149

Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 15

G

ROOM CAVITY RATIOS

Coefficients of Utilization: Zonal Cavity
Method

G2-16

AHL and EHL Incandescent Explosionproof
Lighting Fixtures and Handlamp: Factory Sealed
Suitable for use in Wet Locations.

Applications
AHL general purpose Explosionproof
lighting fixture - an A-51 fixture with
handle assembly of hook and cable
clamp. CAUTION: For safe operation, the AHL fixture weight must be
suppor ted by the hanger hook,
not by the flexible cord, per NEC
502-11(a)(3).
EHL general purpose Explosionproof
portable handlamp. Only 5” in diameter
for ease of movement.
The EHL handlamp may be used
with AE Automatic Take-Up Reelites
listed in Catalog Subsection W3 and
ECC Cord Connector and Plugs and
Receptacles in Catalog Section L.

•

•
G

•

Features: AHL and EHL

• Equipped with connection block for
ease of wiring and relamping.
• Cable clamp diameters: AHL— .375”
to .625”. EHL—.406” for 16-3 AWG.
• Heat- and impact-resistant glass
globes.

AHL Features

• Sturdy fixture with rugged hanging
hook.
• Safety grounding — additional terminal furnished to connect to grounding
conductor.
EHL Features

• Portability, with phenolic handle and
non-sparking guard with hook.
• Easy relamping — loosen setscrew,

unscrew guard, remove globe and
insert lamp.
Safety grounding — remove cable
and clamp and make connections to
terminal (including one ground terminal) then tighten clamp.

•

Standard Materials
Globes: heat-and impact-resistant
glass.
AHL fixture unit, hook and guard:
copper-free aluminum.
AHL cable clamp: brass.
EHL fixture body and handle: laminated phenolic.
EHL handle: laminated phenolic.
EHL hook: brass.
EHL guard: copper-free aluminum.

•
•
•
•
•
•
•

Effective September, 2005
Copyright 2005
PAGE 16

Standard Finishes
AHL fixture unit, guard, handle and
hook: two-coat epoxy enamel.
AHL cable clamp: natural finish.
EHL fixture body: laminated
phenolic.
EHL handle: phenolic.
EHL guard and hook: guard — natural finish, hook — zinc electroplate and
clear chromate.
EHL cable clamp: laminated
phenolic.

•
•
•
•
•
•

Compliances

• UL Standard 1598 (supersedes UL
57) and 844.
• Suitable for use in wet locations.
• Appleton malleable iron products

conform to ASTM A47-77, Grade
32510, which has the following properties: tensile strength, 50,000 psi; yield,
32,000 psi; and elongation, 10%.
A p p l e t o n a l u m i nu m p r o d u c t s
are produced from a high strength
copper-free (4/10 of 1% max.) alloy.

•

800-621-1506
www.appletonelec.com

AHL:
Class I, Div. 1 and 2
Groups C,D
Class II, Div. 1 and 2
Groups F†,G
Class III
EHL:
Class I, Div. 1 and 2
Groups C,D
U.S. Pat. 3,170,750

Pat. Can. 1968

G2-17

AHL and EHL Incandescent
Explosionproof Lighting Fixtures
and Handlamp: Factory Sealed
Suitable for use in Wet Locations.
Cable Dia.
(Inches)

Description

T Ratings

Catalog
Number

AHL—Explosionproof
60-300W Lighting Fixtures

Class I, Groups C and D;
Class II, Groups F and G
CAUTION: For safe operation, weight of fixture
must be supported by hanger hook, not by
the flexible cord, per NEC 502-11(a)3.
.375 to .625

T4

AHL100

200-300 Watt, PS-30
(AAU-2NS)

.375 to .625

T4A

AHL200

T3A

EHL100N

*EHL—Explosionproof
100W Portable Handlamp

Laminated Phenolic Handle. Wiring Connection
Block takes from #16 to #14 Wire.
Class I, Groups C and D
100 Watt, A-21

.406

EHL Replacement
Globe and Guard
XP419
XP163SA

Heat-resistant glass globe
Aluminum guard with hook

† To reduce the risk of ignition of hazardous atmospheres, do not use where electrically conductive dusts are present (most coal dusts are
not electrically conductive). *Handlamp accommodates 16-3 SO cable. Consult factory if 14-3 cable is required.

AHL Dimensions
Dim. in
Inches
Cat. No.,

A

Dim. in
B

C

Centimeters
A

B

C

AHL100

14.25

7.06

10.94

36.2

17.9

27.8

AHL200

15.94

8.81

12.63

40.5

22.4

32.1

EHL Dimensions

Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 17

G

60-100 Watt, A-21
(AAU-1N)

G2-18

Class II, Div. 1 and 2
Groups E,F,G
Class III

EDT Incandescent Dust-Ignitionproof
Lighting Fixtures and Accessories

UL 1598, UL 844

Suitable for use in Wet Locations.

Watts

Hub
Size

Catalog Number

1/2”

EDTP2050

Pendant Lighting Fixture*
One tapped opening for
rigid or flexible mounting,
with heat resistant clear globe

60-200 Watt

Fixture Accessories and Parts

G

Heat Resistant
Clear Glass Globe

60-200 Watt

VSGL-2HR

Globe Guard

60-200 Watt

DPGU-2

Replacement Porcelain
Shock-Absorbing Socket
Medium Base

60-200 Watt

VPLR-123

* T3C maximum operating temperature. Supply wire 150°C. Maximum ambient temperature 25°C. Vertical mount only (globe down).

Effective September, 2005
Copyright 2005
PAGE 18

800-621-1506
www.appletonelec.com

G2-19

ELS Series Emergency Lighting System:
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications

Applications
ELS Series features an emergency
lighting power unit that is designed to
provide safe operation in the presence
of hazardous gasses, vapors, or dusts,
defined by the National Electrical Code
as Class I, Groups C and D, and Class
II, Groups E,F,G.
Typical applications include all means
of egress (such as walkways, exit
ramps, stairs and aisles) for hazardous
areas which include oil refineries, petrochemical facilities, pulp and paper mills,
chemical storage areas, waste water
treatment facilities and grain elevators.

•

•

G

Features
The electronics consist of a solidstate charger, transfer circuit and low
voltage battery disconnect circuit.
The unit test switch and AC “On”
indicator light are housed in a separate
module that may be attached directly to
the unit housing or mounted remotely
for ease of testing.
All ELS Series units are rated for
operation in NEC Class I, Divisions 1 or
2 Groups C and D and Class II, Divisions
1 or 2 Groups E, F, and G environment.
Housing provisions allow for the
attachment of two optional Explosionproof lighting fixtures.
Unit capacity is sufficient for the
connection of up to four, 6- or 12- volt,
18-watt fixtures
Units provide 90 minutes of emergency operation.
The solid-state charger maintains
battery at full charge.
Upon failure of utility voltage, the DC
emergency lighting load is connected to
the battery.
During emergency operation,
automatic battery protection from deep
discharge damage is provided by a
low-voltage battery disconnect (LVD)
circuit.
Upon restoration of normal power,
the charger will begin a recharge cycle.
It will bring the battery to full capacity
within acceptable UL time standards.
A pilot light indicates the presence
of AC line voltage, and a test switch is
provided for checking transfer operation.

•
•
•

•
•
•
•
•
•
•

•

Effective September, 2005
Copyright 2005

Lock out type guard on push button
accepts locks with up to 1/4” hasp.
A universal transformer allows operation on 120 or 277 VAC lines.
Emergency power source is a maintenance-free, sealed, pure-lead battery
suited for harsh temperature environments for 0° to 40°C.
Expected life is 10 years
Compact in design.
Never necessary to add water.
Standard illumination is provided
using fixtures specially designed for
emergency lighting in hazardous
environments, supplied with double
contact bayonet base 18 or 28-watt incandescent lamps.
Designed for easy installation.
Provided with 4 mounting holes for
attachment to a wall or other suitable surface. Mounting hardware not
included.
Housing is drilled and tapped for installation of utility 1/2” NPT conduit.
Quick access to internal wiring and
components is provided by thread-on
cover.
All necessary fittings for test switch/
pilot light module supplied standard.

•
•
•
•
•
•

•
•
•
•

• C e i l i n g a n d b r a cke t m o u n t s :
Malleable Iron with aluminum adapter.
• Pe n d a n t m o u n t : C o p p e r Fr e e
Aluminum.
• Reflectors: Porcelain enameled
steel.
• Test Switch: Copper free Aluminum
with stainless steel hardware.
Standard Finishes

• Enclosure, Fixtures and Test Station:
Epoxy Powder Coat Finish Electrostatically applied for complete and uniform
surface protection
Steel Reflectors: White Porcelain
Enamel.

•

Options

• The

fixture may be adapted to
serve as an exit sign through use of an
Auxiliary Exit Housing.
Time Delay Relay (15 min.) available
to permit normal lighting to re-establish
brightness. Add suffix T1 for 120 VAC
or T2 for 277 VAC.

•

Compliances

• UL 844
• UL 924
• NFPA101 (Life Safety Code)

Standard Materials

• Battery Enclosure: Copper Free
Aluminum.
• Fixtures and guards: Copper Free
Aluminum.

800-621-1506
www.appletonelec.com
PAGE 19

G2-20

Class I, Div. 1 and 2
Groups B*,C,D
Class II, Div. 1 and 2
Groups E,F,G
Class III

ELS Series Emergency Lighting System:
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Catalog Numbering Logic for Emergency Lighting System
ELS

2

Series

18

6

Wattage per lamp
18 - 18 Watt
28 - 28 Watt

G

#
0
1
2

of direct mounted fixtures
- no direct mounted fixtures
- 1 direct mounted fixture
- 2 direct mounted fixtures

T1G

Options
T1 - Time delay relay, 120 VAC input
T2 - Time delay relay, 277 VAC input
G - Guard installed on fixture
Lamp Voltage
6 - 6 VDC
12 - 12 VDC

Reflectors and exit signs ordered separately. See accessories page.

Capacity of standard ELS unit (75 Watt for 90 minutes).

Up to 2 fixtures may be direct mounted.
The remainder must be remote mounted.

Combination
Number

Number of
Fixtures

Wattage per
Fixture

Total
Wattage

1
2
3
4
5
6

1
1
2
2
3
1
2
4

18
28
18
28
18
28
18
18

18
28
36
56
54
64

7

72

* Consult factory for Class I, Group B rating.
Effective September, 2005
Copyright 2005
PAGE 20

800-621-1506
www.appletonelec.com

Class I, Div. 1 and 2
Groups C,D
Class II, Div. 1 and 2
Groups E,F,G
Class III

G2-21

ELS Series Emergency Lighting System:
Explosionproof, Dust-Ignitionproof

Remote and direct mounted fixtures for hazardous location applications

Emergency Lighting System with Direct Mounted Fixtures
Watts per
Lamp

Lamp
Voltage

2
2
2
2
1
1
1
1

18
28
18
28
18
28
18
28

6 VDC
6 VDC
12 VDC
12 VDC
6 VDC
6 VDC
12 VDC
12 VDC

Input
Voltage
120/277
120/277
120/277
120/277
120/277
120/277
120/277
120/277

VAC
VAC
VAC
VAC
VAC
VAC
VAC
VAC

Catalog Number
(Lamp(s) Included)
ELS2186
ELS2286
ELS21812
ELS22812
ELS1186
ELS1286
ELS11812
ELS12812

❶❷❸❹
❶❷❸❹
❶❷❸❹
❶❷❸❹
❶❷❸❹
❶❷❸❹
❶❷❸❹
❶❷❸❹

Emergency Lighting System Enclosure with Battery and Charger
Lamp
Voltage

Input
Voltage

6 VDC
12 VDC

120/277 VAC
120/277 VAC

Catalog Number with
Push-to-Test
(Incl. Fittings)
ELS06 ❶❷❸
ELS012 ❶❷❸

Emergency Lighting System Fixture for Direct Mounting to Enclosure
Includes all necessary fittings and lamp.

❶
❷
❸
❹

Watts
Per Lamp

Lamp
Voltage

Catalog Number
Lamp Included

18
28
18
28

6 VDC
6 VDC
12 VDC
12 VDC

AP1050-186-DM
AP1050-286-DM
AP1050-1812-DM
AP1050-2812-DM

❹
❹
❹
❹

1/2” NPT provided for AC input.
Add suffix T1 for time delay relay for 120 VAC input.
Add suffix T2 for time delay relay for 277 VAC input.
To order fixtures with guard installed add suffix – G. Reflectors and exit signs are ordered separately. See accessories page.

Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 21

G

Number of
Fixtures

G2-22

Class I, Div. 1 and 2
Groups C,D
Class II, Div. 1 and 2
Groups E,F,G
Class III

ELS Series Emergency Lighting System:
Explosionproof, Dust-Ignitionproof
Remote and direct mounted fixtures for hazardous location applications

Emergency Lighting System Fixture for Remote Mounting
Lamp included

G
Pendant Mount

Long Bracket Mount

Ceiling Mount

Mounting
Type

Short Bracket Mount

Watts
Per Lamp

Lamp
Voltage

Catalog Number
Lamp Included ❶

Pendant
One 1/2” Hub

18
28
18
28

6 VDC
6 VDC
12 VDC
12 VDC

AP1050-186
AP1050-286
AP1050-1812
AP1050-2812

Ceiling
Four 1/2” Hubs,
Three Close-Up Plugs

18
28
18
28

6 VDC
6 VDC
12 VDC
12 VDC

AC1050-186
AC1050-286
AC1050-1812
AC1050-2812

Long Bracket
Four 1/2” Hubs,
Three Close-Up Plugs

18
28
18
28

6 VDC
6 VDC
12 VDC
12 VDC

ALB1050-186
ALB1050-286
ALB1050-1812
ALB1050-2812

Short Bracket (15 degrees)
Two 1/2” Hubs,
One Close-Up Plug

18
28
18
28

6 VDC
6 VDC
12 VDC
12 VDC

ASB1050-186
ASB1050-286
ASB1050-1812
ASB1050-2812

Emergency Lighting System Replacement Fixtures
Lamp included. Fits existing mounting hood
Watts
Per Lamp

Lamp
Voltage

Catalog Number
Lamp Included ❶

18
28
18
28

6 VDC
6 VDC
12 VDC
12 VDC

AAU1N-186
AAU1N-286
AAU1N-1812
AAU1N-2812

❶ To order fixtures with guard installed add suffix – G. Reflectors and exit signs are ordered separately. See accessories page.
Effective September, 2005
Copyright 2005
PAGE 22

800-621-1506
www.appletonelec.com

G2-23

ELS Series Emergency Lighting System:
Accessories, Replacement Parts and
Technical Data
Description

Catalog Number

Guard

AAGU1

Three-Way Exit Sign
Epoxy enameled steel — 6”-high red lettering

CJEXRN

Mounts to fixture units in place of guard.
Single Sided Exit Sign
Epoxy enameled steel — 6”-high red lettering

G

AEXR-15R

Mounts to fixture units in place of guard.

30° Angle Reflector

AARW15AN

Standard Dome Reflector

AARW15ST

Push-to-Test Station
Cover with Switch and Pilot Light
Switch Only
Pilot Light Only

EFDCB150J1U1-T-A
EFKB-J1U1-TEST
SPBB-U1-Q
SPLNS-RE-B

Lamp,
Lamp,
Lamp,
Lamp,

59620527074
59620527075
59620527076
59620527078

18
28
18
28

W,
W,
W,
W,

6 VDC
6 VDC
12 VDC
12 VDC

Technical Data: Operating Temperature
Lamp
Watts

Supply Wire
Temp (degrees C)

Ambient Temp
(degrees C)

Class I, Div. 1 & 2
Operating Temperature

Class II, Division 1 & 2 (Groups E, F & G)
Operating Temperature

18
28

125
125

40
40

T5
T5

T3C
T3C

Operating temperatures are with and without reflectors and guards
“T” numbers represent the maximum surface temperature for Class I, Div. 1 locations and the maximum surface temperature under dust
blanket for Class II, Div. 1 locations.
“T”
Number

Temp.
Range
(°C)

T1

350

325

T2

T2A

T2B

T2C

T2D

T3

T3A

351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180

T3B

T3C

T4

T4A

T5

T6

161-165 136-160 121-135 101-120 86-100 85

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be
encountered per NEC 500-2(c).
Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 23

G2-24
ELS Series Emergency Lighting System:
Weights and Dimensions

Weights
Weight (lbs.)

Catalog Number

Weight (lbs.)

ELS06, ELS012
AP1050-186-DM
AP1050-186
AC1050-186
ALB1050-186
ASB1050-186
EFDCB150J1U1-T-A

52
11
9
12.5
16.6
12.5
4

Catalog Number
AAU1N-186
AAGU1
AEXR-15R
CJEXRN
AARW15AN
AARW15ST

7.6
0.4
5
5
2.1
2.1

Dimensions (In Inches)

14.69

13.50

G

14.38

.38
1.31

10.75

12.00

14.12

12.25

11.63
12.25

13.13

Battery Enclosure

7.06

Direct Mount fixture

4.75

2.63

2.69

5.38 3.38

Pendant Mount

.38
45°

13.56

13.13
13.75

12.94

13.13
13.75
9.13

12.38
7.06

Long Bracket Mount

Ceiling Mount

Short Bracket Mount

3.00
6.88
11.75

5.41

7.63

.00

10

8.50

AEXR-15R

EFDCB150J1JU1-T-A
33.50

AARW15AN

13.00
9.25

4.38

28.67
12.00
14.00

ELS with 2 direct mounted fixtures
Effective September, 2005
Copyright 2005
PAGE 24

CJEXRN

AARW15ST
800-621-1506
www.appletonelec.com

Code•Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures:
Explosionproof, Dust-Ignitionproof

G2-25

Applications
Code•Master Explosionproof Strobe
and Beacon Fixtures are designed to
provide safe operation in the presence of
hazardous gases, vapors, or dusts, defined by the National Electrical Code as
Class I, Groups C and D, and Class II,
Groups E, F and G.
For use in hazardous locations such
as plants where plastics, paints, thinners
and petrochemicals are manufactured.
In areas where audible signals cannot
be heard.
To warn of unsafe conditions and other
communication needs.
-25°C minimum operating temperature.

•

•

G

•
•
•

Features

•
•
•
•
•
•

Fixtures operate safely in high ambient
temperatures.
Available for fire alarm hearing
impaired.
Strobe 65 flashes per minute.
Beacon 75 rotations per minute.
Fixtures are complete with lamp.
Patented “wireless” design. Threading of
fixture unit onto mounting hood makes
electrical connection. The only wiring
required is attaching two wires to connection block in mounting hood.
Connection block is easily wired:
(a) loosen two screws, (b) make wire
connections, (c) re-position connection
block.
Safe, easy servicing without disconnecting any wiring. “Wireless” fixture unit
threads off mounting hood for convenient
servicing or for immediate replacement
with a “stand-by” unit.
Acme double-lead threads speed
installation and fixture removal from
mounting hood only half as many
turns are required as for single-lead
threads. The threads do not stick
or gall, eliminating problems often
encountered with single-lead threads
during fixture unit removal.
All threaded joints are flame-tight.
Lens available in five colors: Red,
Amber, Blue, Green and Clear. (Factory
installed).
Factory sealed. External seals not required.
Heat and impact resistant globes
have smooth dust-resistant exterior.

Fixtures are suitable for mounting in any position including globe up or globe
down utilizing pendant, ceiling or wall bracket type mounts.
Fixtures shown with optional guard.

•
•
•

•
•
•
•

Effective September, 2005
Copyright 2005

•
•

Superior corrosion-resistance, with
epoxy powder coat finish.
Fixture is suitable for mounting globe
up or globe down utilizing pendant,
ceiling or wall bracket type mounts.
Optional guards protect globes from
damage. Secured to fixture with three
stainless steel screws.

•

Standard Materials
Fixture housing and guards: copperfree aluminum (less than 4/10 of 1%
maximum copper content).
Mounting hoods: copper-free aluminum (less than 4/10 of 1%).
Globes: Prismatic Glass.

•
•
•

Standard Finishes
Fixture housing, guards and mounting hoods: Epoxy power coat finish,
electrostatically applied for complete,
uniform corrosion protection.

•

Compliances

• UL and cUL Listed.
• Class I, Div. 1 and 2, Groups C and D.
• Class I, Div. 2, Groups A, B, C and D.
• Class II, Div. 1 and 2, Groups E, F, and G.
• Class III.
• Type 3R and 4X
• Marine Outside Type (Saltwater).
• UL 1203.
• UL 1638 Visual Signaling Appliances.
• UL 1971 Visual Signaling Equipment

has been investigated for fire protective signaling services to alert hearing
impaired persons. This signaling equipment is intended to be used in conjunction with Listed compatible units and
devices. Visual signaling equipment
Listed in this category is intended to be
used in the “Public Operating Mode” as
defined in NFPA 72.

800-621-1506
www.appletonelec.com
PAGE 25

G2-26

Code•Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures:
Explosionproof, Dust-Ignitionproof

Ordering Information:
Order using catalog numbering guide below or select catalog number from pages G2-27 through G2-30.

CATALOG NUMBERING GUIDE FOR CODE-MASTER STROBE AND BEACON LUMINAIRES

CS

S

P

75
HUB SIZE:
75 - 3/4”

MOUNTING
HOOD:

SERIES:

G

CS - Code-Master
Signal

TYPE:

120AC

P - PENDANT
B - WALL BRACKET
C - CEILING

S - Strobe
B - Beacon

CL

P

GLOBE:

CL - Clear
AM - Amber**
BL - Blue**
GR - Green**
RE - Red**

VOLTAGE CURRENT:
120AC - 120VAC
240AC - 240VAC
250DC - 250VDC
1248DC - 12-48VDC†
2030DC - 20-30VDC*
2428DC - 24-28VDC***††
24DC - 24VDC***

OPTIONS:

P - Hearing
Impaired
(UL1971)
(Strobe Only)
G - Guard

* UL1971 Strobe Only
** Not for use with UL1971 Strobe
*** Diode Polarized (Current limiter supplied as standard).
†Strobe Only
††Beacon Only

Technical Data: Thermal Suitability of Code-Master Strobe and Beacon Fixture.

Operating Temperatures
Class I, Div. 1 and 2
Groups C & D
Strobe
Beacon

Ambient
Temp.

40°C
55°C
65°C

T6
T6
T6

Class I, Div. 2
Groups A & B
Strobe
Beacon

T6
T5
T5

T2B
T2B
T2A

Class II, Div. 1 & 2
Class III
Strobe
Beacon

450°C
450°C
450°C

T4A
T4A
T4

T4A
T4A
T4

Operating Temperatures: Represent the Maximum Internal Temperature for Class I, Div. 2 Locations and
Maximum Surface Temperature for Class I, Div. 1 Locations, and Maximum Surface Temperature Under Dust
Blanket for Class II, Div. 1.
“T’
Number
Temp
Range
(°C)

T1

350

325

T2

351-450 326-350 301-325 281-300

T2A

TB

T2C

261-280 231-260 216-230

T2D

T3

201-215 181-200

T3A

T3B

T3

T4

T4A

T5

166-180 161-165 136-160 121-135 101-120 86-100

T6
85

NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be
encountered per NEC 500-5(e, f ).

Effective September, 2005
Copyright 2005
PAGE 26

800-621-1506
www.appletonelec.com

Class I, Div. 1 and 2, Groups C,D
Class I, Div. 2, Groups A,B
Class II, Div. 1 and 2
Groups E,F,G
Class III
NEMA 3R, 4X
UL and cUL Listed
Standards UL 1638 and UL1203
Suitable for Wet Locations
Marine Outside Type (Saltwater)

Code•Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures:
Explosionproof, Dust-Ignitionproof

Pendant

Strobe

One Hub 3/4” NPT
Rigid Conduit.

Beacon

G2-27
Catalog Number* †
CSSP75120ACCL
CSSP75240ACCL
CSSP75250DCCL
CSSP751248DCCL
CSSP7524DCCL**

120VAC
240VAC
24-28VDC

CSBP75120ACCL
CSBP75240ACCL
CSBP752428DCCL**

120VAC
240VAC
250VDC
12-48VDC
24VDC

CSSC75120ACCL
CSSC75240ACCL
CSSC75250DCCL
CSSC751248DCCL
CSSC7524DCCL**

120VAC
240VAC
24-28VDC

CSBC75120ACCL
CSBC75240ACCL
CSBC752428DCCL**

120VAC
240VAC
250VDC
12-48VDC
24VDC

CSSB75120ACCL
CSSB75240ACCL
CSSB75250DCCL
CSSB751248DCCL
CSSB7524DCCL**

120VAC
240VAC
24-28VDC

CSBB75120ACCL
CSBB75240ACCL
CSBB752428DCCL**

G

Volts
120VAC
240VAC
250VDC
12-48VDC
24VDC

Ceiling

Strobe

Rigid Conduit
Four Hubs 3/4” NPT
Three Close-Up Plugs
Beacon

Wall Bracket

Strobe

Rigid Conduit
Four Hubs 3/4” NPT
Three Close-Up Plugs
Beacon

* Catalog numbers shown are supplied with clear lens. Add G suffix for optional Guard.
** Diode Polarized (Current limiter supplied as standard).
†To order colored lens replace last digits of catalog number CL with AM for Amber, BL for Blue, GR for Green, RE for Red.
Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 27

G2-28

Code•Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures:
Mounting Hoods, Fixture Units, Weights

Mounting Hoods:

Type Mounting

Hub Size (In.)

Hood Weight

Catalog Number

Pendant
One Hub
Rigid Conduit

3/4

2 lbs.

CAP75

Ceiling
Four Hubs
Three Close-Up Plugs
Rigid Conduit

3/4

4 lbs.

CAC75

3/4

6 lbs.

CALB75

Volts

Unit Weight

Catalog Number*†

G

Class I, Div. 1 and 2, Groups C,D
Class I, Div. 2, Groups A,B
Class II, Div. 1 and 2
Groups E,F,G
Class III
NEMA 3R, 4X
UL and cUL Listed
Standards UL 1638 and UL1203
Suitable for Wet Locations
Marine Outside Type (Saltwater)

Bracket
Four Hubs
Three Close-Up Plugs
Rigid Conduit

Fixture Unit Only: (not including mounting hood)
Strobe

120VAC
240VAC
250VDC
12-48VDC
24VDC

10
10
10
10
10

Beacon

120VAC
240VAC
24-28VDC

10 lbs. 10 oz.
10 lbs. 10 oz.
10 lbs. 10 oz.

lbs.
lbs.
lbs.
lbs.
lbs.

3
3
3
3
3

oz.
oz.
oz.
oz.
oz.

CSST120ACCL
CSST240ACCL
CSST250DCCL
CSST1248DCCL
CSST24PDCCL**
CSB120ACCL
CSB240ACCL
CSB2428PDCCL**

† To order colored lens replace last digits of catalog number CL with AM for Amber, BL for Blue, GR for Green, RE for Red.
Effective September, 2005
Copyright 2005
PAGE 28

800-621-1506
www.appletonelec.com

Class I, Div. 1 and 2, Groups C,D
Class I, Div. 2, Groups A,B
Class II, Div. 1 and 2
Groups E,F,G
Class III
NEMA 3R, 4X
UL and cUL Listed
Standards UL 1638 and UL1203
Suitable for Wet Locations
Marine Outside Type (Saltwater)

Code•Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures:
Explosionproof, Dust-Ignitionproof

G2-29

Strobes For The Hearing Impaired
Strobes:

Volts

Hearing Impaired Catalog Number
UL1971 - Hearing Impaired*

Pendant
One Hub 3/4” NPT
Rigid Conduit

20-30VDC

CSSP752030DCCLP

Ceiling
Rigid Conduit,
Four Hubs 3/4”
NPT, Three
Close-Up Plugs

20-30VDC

CSSC752030DCCLP

Bracket
Rigid Conduit,
Four Hubs 3/4”
NPT, Three
Close-Up Plugs

20-30VDC

CSSB752030DCCLP

G

Mounting Hoods:

Type Mounting

Type Mounting

Hub Size (Inches)

Hearing Impaired Catalog Number

Pendant
One Hub
Rigid Conduit

3/4

CAP75-1971

Ceiling
Four Hubs
Three Close-up Plugs
Rigid Conduit

3/4

CAC75-1971

Bracket
Four Hubs
Three Close-up Plugs

3/4

CALB75-1971

Volts

Hearing Impaired Catalog Number

20-30VDC

CSST2030PDCCL

Fixture Unit Only: (less mounting hood)

Connection Block: (replacement part)

Hearing Impaired Catalog Number
For Hearing Impaired
Code-Master Fixtures

VPT-7P

* Only clear globes are available for UL1971 Applications.
Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 29

G2-30

Code•Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures:
Accessories, Replacement Parts, Weights

Description

Weight

Catalog
Number

1.0 lbs.

CJGU-15

0.5 lbs.

VPT-7

Optional Aluminum Guard
Copper-Free Aluminum.

G
Replacement Connection Block
For Non-Hearing Impaired
Code-Master Fixtures.

Replacement Lamps
For Strobe and Beacon Code-Master Fixtures.

125-240AC

S865

Fixture Type

Lamp Type

Voltage

Wattage

Base Type

Catalog Number

Beacon

Halogen

120VAC

40W

DBL Bayonet

Q4OA9-120AC

Beacon

Halogen

24-28VDC

18W

DBL Bayonet

Q20A-24VDC

Beacon

Incand.

240VAC

25W

DBL Bayonet

125-240AC

Strobe

Xenon

All

--------

Octal Socket

S865

Q4OA9-120AC
Q20A-24VDC

Effective September, 2005
Copyright 2005
PAGE 30

800-621-1506
www.appletonelec.com

G2-31

Code•Master™ Strobe and Beacon
Factory Sealed Lighting Fixtures:
Family Tree and Dimensions
Pendant
One Hub
—
3/4” NPT
CAP75
CAP75-1971

Ceiling
Four Hubs
Three Close-Up Plugs
3/4” NPT
CAC75
CAC75-1971

Bracket
Four Hubs
Three Close-Up Plugs
3/4” NPT
CALB75
CALB75-1971

Fixture Unit With Globe
120AC
240AC
12-48DC
250DC
20-30DC
24DC

Beacon

120AC CSB120ACCL
240AC CSB240ACCL
24-28DC CSB2428PDCCL**

G

CSST120ACCL
CSST240ACCL
CSST1248DCCL
CSST250DCCL
CSST2030PDCCL*
CSST24PDCCL**

Strobe

Optional Aluminum Guard
CJGU-15
* UL1971 (See page G2-25).
** Diode Polarized (Current limiter supplied as standard).

Dimensions:
Wall Bracket

Ceiling

Pendant

Hub For
3/4” NPT
Hub for 3/4”
NPT Conduit.

2” Wiring access
cover both sides.

4.50”

3.75”

Hub for 3/4” NPT
Conduit Four Sides

.94”
5.95”

13.88”

13.15”
4”

4.92”

13.53”

12.38”
13.38”

13.00”
13.75”

7.80”
7.80”

Effective September, 2005
Copyright 2005

7.80”

800-621-1506
www.appletonelec.com
PAGE 31

G2-32

UL and cUL Listed
Class I, Div. 1, Groups C,D
Class I, Zone 1, Group IIB
Class II, Div. 1 and 2, Groups E,F,G
Class III
UL 844
UL 1598A
NEMA 3R and 4X
Applications
Code•Master Incandescent
Explosionproof Fixtures are designed to
provide safe operation in the presence
of hazardous gases, vapors, or dusts,
defined by the National Electrical Code
as Class I, Groups C and D, Class I,
Zone 1, Group IIB and Class II, Groups
E, F and G.
For use in hazardous locations such
as plants where plastics, paints, thinners and petrochemicals are manufactured.
For use in chemical and petrochemical plants, such as manufacturers of
plastics, paints, and thinners, in refineries, and in other areas where ignitable
vapors, dust, moisture and corrosive
elements may be present.
Suitable for outdoor saltwater locations and for other wet locations.

Code•Master™ Incandescent Factory
Sealed Lighting Fixtures:
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.

•

•

G

•

•

Features

•
•

Fixtures operate safely in high ambient temperatures.
Patented “wireless” design. Threading
of fixture unit onto mounting hood
makes electrical connection. The only
wiring required is attaching two wires
to connection block in mounting hood.
Connection block is easily wired: (a)
loosen two screws, (b) make wire connections, (c) re-position connection
block.
Safe, easy servicing without disconnecting any wiring. “Wireless” fixture
unit threads off mounting hood for convenient servicing or for immediate replacement with a “stand-by” unit.
Acme double-lead threads speed
installation and fixture removal from
mounting hood only half as many turns
are required as for single-lead threads.
The threads do not stick or gall, eliminating problems often encountered with
single-lead threads during fixture unit
removal.
Strategic location of lamp socket, in
combination with interior prism design
of the glass globe, provides optimum
light distribution and control.
Heat-and impact-resistant globes
have smooth dust-resistant exterior.
Superior corrosion-resistance, with
epoxy powder coat finish.

•
•
•

•
•
•

Effective January, 2007
Copyright 2007
PAGE 32

• Porcelain socket with nickel plated

phosphor bronze screw shell. Assures
long trouble-free operation in high
ambient areas.
Choice of mountings: pendant,
ceiling, bracket and stanchion.
Fiberglass reinforced polyester
reflectors, in standard dome, or 30°
angle styles, are ideal in installations
where luminaire is subject to exceptionally severe corrosive atmospheres.
All threaded joints are flame-tight.
Heat and impact resistant globes
have smooth dust-resistant exterior.
Superior corrosion-resistance, with
epoxy powder coat finish.
Optional guards protect globes from
damage. Secured to fixture with three
stainless steel screws.

•
•
•
•
•
•

Standard Materials
Fixture housing and guards: copperfree aluminum (less than 4/10 of 1%
maximum copper content).
Mounting hoods: copper-free aluminum (less than 4/10 of 1%).

• Globes: Prismatic Glass.
• Reflectors: fiberglass reinforced polyester.
Standard Finishes
• Fixture housing, guards and mount-

ing hoods: Epoxy power coat finish,
electrostatically applied for complete,
uniform corrosion protection.
Compliances
UL and cUL Listed.
Class I, Div. 1, Groups C and D.
Class I, Zone 1, Group IIB.
Class II, Div. 1 and 2, Groups E,
F, and G.
Class III.
UL 844 Hazardous Locations
UL 1598A Marine Type Electric
Fixtures Outside Type (Salt Water)
Outdoor Wet Locations
NEMA 3R and 4X

•
•
•
•
•
•
•
•

•
•

800-621-1506
www.appletonelec.com

Code•Master™ Incandescent Factory
Sealed Lighting Fixtures:
Explosionproof, Dust-Ignitionproof

G2-33

For use with threaded metal conduit.
Ordering Information:
Order using catalog numbering guide below or select catalog number from pages G2-34.

CATALOG NUMBERING GUIDE FOR CODE-MASTER INCANDESCENT LUMINAIRES

CI

P

30

75

G

SERIES:

MOUNTING
HOOD:

WATTAGE:

HUB SIZE:

OPTIONS:

CI – Code•Master
Incandescent

30 – 100W A21
200W A23
300W PS25

75 – 3/4”
100 – 1”
150 – 1-1/4” or
1-1/2”

G
– Guard
Blank – No Guard

G

P – Pendant
B – Wall Bracket
C – Ceiling
S – Stanchion

Technical Data: Thermal Suitability of Code-Master Incandescent Fixture.
Lamp Watts
(Max.)

Use Wire Supply

Ambient
Temperature

Class I, Division 1,
Groups C & D

Class II, Division 1,
Groups E, F & G

Incandescent (A21)

100

75°C

40°C

T5

T3C

Incandescent (A23)

200

75°C

40°C

T4

T3C

Incandescent (PS25)

300

75°C

40°C

T3C

T3C

Lamp Type

“T” Numbers Represent the Maximum External Temperature for Class I, Div. 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Div. 1 Locations.
“T”
Number

T1

350

325

T2

T2A

T2

T2C

T2D

T3

T3A

T3B

T3

T4

T4A

T5

T6

Temp
Range
(C°)

351450

326350

301325

281300

261280

231260

216230

201215

181200

166180

161165

136160

121135

101120

86100

85

NOTE:
The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per NEC 500-5(e, f ).

Effective January, 2007
Copyright 2007

800-621-1506
www.appletonelec.com
PAGE 33

G2-34

UL and cUL Listed
Class I, Div. 1, Groups C,D
Class I, Zone 1, Group IIB
Class II, Div. 1 and 2, Groups E,F,G
Class III
UL 844
UL 1598A
NEMA 3R and 4X

Code•Master™ Incandescent Factory Sealed
Lighting Fixtures: Fixtures, Mounting Hoods
For use with threaded metal conduit.

Hub Size (In.)

Catalog Number *

One Hub

3/4

CIP3075

Rigid Conduit.

1

CIP30100 †

Rigid Conduit

3/4

CIC3075

Four Hubs

1

CIC30100 †

Rigid Conduit

3/4

CIB3075

Four Hubs

1

CIB30100 †

1-1/2 ♦

CIS30150

Pendant

Ceiling

G

Three Close-Up Plugs
Wall Bracket

Three Close-Up Plugs
25° Stanchion
One Hub

* Catalog numbers shown are supplied with clear lens. Add suffix G for optional Guard.

Mounting Hoods:

Type Mounting

Hub Size (In.)

Hood Weight

Catalog Number

Pendant

3/4

2 lbs.

CAP75

One Hub

1

2 lbs.

CAP100 †

Rigid Conduit
Ceiling

3/4

4 lbs.

CAC75

Four Hubs

1

4 lbs.

CAC100 †

Three Close-Up Plugs
Rigid Conduit
Bracket

3/4

6 lbs.

CALB75

Four Hubs

1

6 lbs.

CALB100 †

Three Close-Up Plugs
Rigid Conduit
25° Stanchion

1-1/4 or 1-1/2 ♦

CAS-150 ♦

One Hub

♦ 1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
† 1” Hubs are listed for Group D only.

Effective January, 2007
Copyright 2007
PAGE 34

800-621-1506
www.appletonelec.com

UL and cUL Listed
Class I, Div. 1, Groups C,D
Class I, Zone 1, Group IIB
Class II, Div. 1 and 2, Groups E,F,G
Class III
UL 844
UL 1598A
NEMA 3R and 4X

G2-35

Code•Master™ Incandescent Factory Sealed
Lighting Fixtures: Fixture Unit, Accessories,
Replacement Parts, Weights
For use with threaded metal conduit.

Fixture Unit Only: (not including mounting hood)

Catalog Number
CJNC30I

Accessories

Description

Weight

Catalog Number

G

Optional White Polyester Reflector
Standard Dome

KR2-ST

2.5 lbs.

Optional White Polyester Reflector
Angled Reflector

2.5 lbs.

KR2-AN

0.5 lbs.

CJGU-15

Optional Aluminum Guard
Copper-Free Aluminum.

Optional Three Way Exit Sign
CJEXRN
Replacement Connection Block
VPT-7

0.5 lbs.

Fixture and Accessory Weights
Fixture

Mounting Hood

Effective January, 2007
Copyright 2007

Fixture Weight

Reflector Weight

Guard Weight

11 lbs.

3 lbs.

1 lb.

Pendant

Ceiling

Bracket

Stanchion

2 lbs.

4 lbs.

6 lbs.

2 lbs.

800-621-1506
www.appletonelec.com
PAGE 35

G2-36

UL and cUL Listed
Class I, Div. 1, Groups C,D
Class I, Zone 1, Group IIB
Class II, Div. 1 and 2, Groups E,F,G
Class III
UL 844
UL 1598A
NEMA 3R and 4X
Pendant
One Hub
3/4” NPT
CAP75

Code•Master™ Incandescent Factory Sealed
Lighting Fixtures: Family Tree, Dimensions
For use with threaded metal conduit.

Ceiling
Four Hubs
Three Close-Up Plugs
3/4” NPT
CAC75

Bracket
Four Hubs
Three Close-Up Plugs
3/4” NPT
CALB75

25° Stanchion
One Hub
1-1/4 or 1-1/2” NPT
CAS150

G

Code•Master
Incandescent
Fixture Unit
CJNC30I

Standard Dome
KR2-ST

Optional Aluminum
Guard
CJGU-15

Angle Reflector
KR2-AN

Optional Three Way
Exit Sign
CJEXRN

Dimensions:
Pendant

Hub for 3/4”
NPT Conduit.

Wall Bracket

4.50”

Hub For
3/4” NPT

13.88”
2” Wiring access
cover both sides.

4.92”

3.75”

12.38”

13.15”

13.75”

7.80”

25° Stanchion
7.80”

Hub for 3/4” NPT
Conduit Four Sides

.94”

25°

5.95”

Ceiling
4”
11.93”
13.38”

12.87”

13.00”

11.43”
12.48”
7.80”

Effective January, 2007
Copyright 2007
PAGE 36

800-621-1506
www.appletonelec.com

G2-37

®
G

Effective September, 2005
Copyright 2005

800-621-1506
www.appletonelec.com
PAGE 37



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:11:07 09:35:32-06:00
Create Date                     : 2008:10:14 13:21:09-05:00
Metadata Date                   : 2008:11:07 09:35:32-06:00
Format                          : application/pdf
Title                           : G2 1-32 Updated.indd
Creator                         : moleary
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:6fadc51b-8d01-47be-9a53-36ddeca3c738
Instance ID                     : uuid:bc36a23d-e13c-431e-bec0-d514d9f0c53a
Has XFA                         : No
Page Count                      : 37
Page Layout                     : OneColumn
Author                          : moleary
EXIF Metadata provided by EXIF.tools

Navigation menu