DP/OP/PR/SK/SP Series
Installation Instructions, Standard or Slot Grid Ceiling Systems
Page 1 of 2
45 Industrial Way, Wilmington, MA 01887 (978) 657-7600 • Fax (978) 658-0595
We reserve the right to change details of design, materials and finish. www.lightolier.com
This product may have a mercury containing lamp. Manage in accordance with Disposal Laws.
See: www.lamprecycle.org 59-30907-002 Rev. A
01/10
2For individual fixtures, beginning or end of row, assemble
End Trim (full trim) as shown.
Assemble Corner Spline (1) to End Trim by inserting Corner
Spline into end of End Trim. Remove Protective Covering from
Double Face Tape (fastened to End Trim). Insert Corner Spline
(2) into end of Side Trim.
On Overlay and Plaster Frame type, End Trim must be assem-
bled before fixture is installed.
Note: Louver must be removed before installing fixture into
ceiling.
For continuous row mounting use Half Trim (must be ordered
separately from factory) and replace Hex Head Screws with Flat
Head Screws provided in Half Trim Supply Pack.
1Access Plate
Remove Access Plate by sliding Access Plate in the di-
rection of Arrow 1. To remove, lift up and slide in the di-
rection of Arrow 2. Bend Fixture Tab up out of body and
make ground and ballast connections. Bend Fixture Tab
back to original position. Replace Access Plate by revers-
ing removal instructions.
3
Access
Plate
Access Plate Opening
Fixture Tab
Ground Screw
Access Plate
Opening
Tab
1.
2.
Access Plate Opening
Housing
Louver
Side Trim
Double Face
Tape/Covering
End Trim
(full trim)
Corner
Spline
1
2
1
2
4
Hinge
Hinge Slot
Spring Latch
Door Frame
Louver and Lens Frame Installation
Place hinge in hinge slot on side rail of Fixture. Be sure
hinge is seated in hinge slot properly. Rotate Free Edge
up into Fixture and secure with Spring Loaded Latches.
To remove Lens Frame, push leg on Spring Loaded
Latches towards center of Fixture and reverse installation
instructions.
Fixture
Free Edge
Spring
Loaded
Latches
SP Door Frame
For relamping open Door Frame by pressing Spring
Latch in the direction of the arrows (both ends of Door
Frame). Lift Door Frame to clear Hinge from Hinge Slot.
To replace Door Frame, reverse the procedure.
5
For DPA/DPS fixtures
To open Louver, place finger between T-bar and Louver.
Press Spring Latch (each end) towards center of the
fixture. To close, swing Louver up and secure with Spring
Latches.
T-bar
Louver
Louver Spring Latch
Spring Latch
6Opalescent, Prismalyte Plus or Skyway Door Frame
For relamping, open Door Frame by pushing up on the
Spring Latch, (both ends of Door Frame) then lift Door
Frame to clear Hinge from Hinge Slot. To replace the
Door Frame, reverse procedure.
Hinge Slot
Door Frame
Hinge
Spring Latch
45 Industrial Way, Wilmington, MA 01887 (978) 657-7600 • Fax (978) 658-0595
We reserve the right to change details of design, materials and finish. www.lightolier.com
This product may have a mercury containing lamp. Manage in accordance with Disposal Laws.
See: www.lamprecycle.org
DP/OP/PR/SK/SP Series
Installation Instructions, Standard or Slot Grid Ceiling Systems
Page 2 of 2
59-30907-002 Rev. A
01/10
Built-in Earthquake Clip
(opened position)
Fixture
8
To blank out air, install Air Closure Strip
Cover Air Vents with Air Closure Strip
and slide in direction of arrow until Air
Closure Strip locks into place
Optional Air Closure Strip (Air Handling 1'x4' / 2'x2' / 2'x4')
Ceiling Tee
(by others)
Screw (by others)
Earthquake
Clip
Air Closure
Strip
Air
Vent
(Fixture)
Air Closure Strip
Factory Installed. Catalog Number Suffix:
ACS2 (2'x 2' Units); ACS4 (1'x 4', 2'x 4' Units)
Field Installed. Catalog Number Suffix:
ACS2 CSP (2'x 2' Units), ACS4 CSP (1'x 4', 2'x 4' Units)
Air Closure
Strip
Air Closure
Strip
Air Vent
(Fixture)
Fixture
Earthquake
Clip
Screw
(by others)
9
Earthquake Clip (For 2' X 2' / 2'x4' only)
Swing-out Built-
in Earthquake
Clips at each
end of Fixture.
Angle Fixture up into ceiling opening with Built-in Earthquake
Clips (in the opened position) resting on Ceiling Tees (by oth-
ers). Bend Built-in Earthquake Clips back flush against Ceil-
ing Tee (by others) and secure with Screw (by others).
Built-in Earthquake Clip
(before installation)
Fixture
Built-in Earthquake
Clip
(opened position)
Ceiling Tee
(by others)
Fixture
Ceiling Tee
(by others)
Fixture Built-in
Earthquake
Clip
Screw (by others)
7Earthquake Clip (For 1'x4' only)
Ceiling Tee (by others)
Fixture (End Cap)
Angle Fixture up into ceiling opening, resting Fixture on
Ceiling Tees (by others). With Screw (by others) secure
Earthquake Clip to Fixture with Ceiling Tee (by others)
between Earthquake Clip and Fixture as shown.