Loadcenters and Circuit Breakers
Residential Loadcenters
and Breaker Family

1.1

Type CH Loadcenters and Circuit Breakers
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2

21
22
24
29

43
65
67
69
72

1
1
1
1
1
1
1

89
90
91

Classified Circuit Breakers
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1

Loadcenter Interiors
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.4

19

Type BR Loadcenters and Circuit Breakers
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.3

2

92
93
95
95
96

1
1
1
1
1
1
1

Learn
Online

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Eaton Type CH Convertible Family

Contents
Description

1

Overview
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1

Page
3
3
5
6
7
17
19
21
22
24
25
29

1
1
1

Overview

1

Product Selection Guide

1

CH Loadcenters

1

Description
Service

1

Single-phase, three-wire, 120/240 Vac
Three-phase, three-wire, 240V corner grounded delta (see Accessories Page 26)

1

Short-Circuit Current Rating

1
1

10 kAIC: All single- and three-phase loadcenters 40–400A, 2–42 circuits except when
series ratings are applied

Three-phase, four-wire, 208Y/120 Vac
Three-phase, three-wire, 240 Vac delta

35 kAIC: All convertible and factory-installed main breakers single-phase loadcenters rated 150–225A using
Type CSH main breakers
42,000 and 100,000 are available on some styles: single-phase and three-phase

Main Breaker/Main Lug Loadcenters

1

Single-phase
Main breaker: 100, 125, 150, 200, 225, 400A
Main lugs: 40, 70, 125, 150, 200, 225, 400A

1

Convertible Loadcenters

Three-phase
Main breaker: 150, 200, 225, 300, 400A
Main lugs: 125, 150, 200, 225, 400A

Main breaker or main lugs: single-phase up to 225A

1
1
1
1

Branch Breakers
Type CH: 10–150A. Single-, two- and three-pole. Selected amperages available in shunt
trip, HACR and switching duty
Ground fault circuit interruptors: 15–60A
Type CH-HID: 15–30A. Single-, two- and three-pole
CH-HM high magnetic
CH-M50 high ambient

Type CH-AFCI arc fault circuit interrupter
Type CHP: 10–125A. Single-, two- and three-pole. three-position commercial trip
Selected amperages available in HACR switching duty
Type CHP-HID: 15–30A. Single-, two- and three-pole
Type CHP-GFCI: 15–30A. Single-pole ground fault breakers

Enclosures

1
1
1
1
1
1

NEMA® Type 1 indoor

NEMA Type 3R outdoor.

Loadcenter and Breaker Accessories
Branch circuit breaker:
Auxiliary components
Hold-down kits
Handle ties
Lockoffs
Lockdogs

Complete line of ground bar kits 5, 10, 14 and 21 circuits, some with additional #2/0 lugs
Each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
Sub-feed lugs 125, 150A—two- and three-pole
Shunt trips
Universal rainproof conduit hubs Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm)
Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)
Adapter plate

Bussing
Silver flash plated copper bus is a standard feature

2

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Product Description

Features, Benefits and Functions

Loadcenters are enclosures
specifically designed to
house the branch circuit
breakers and wiring required
to distribute power to
individual circuits. They
contain either a main breaker
when used at the service
entrance point or a main lug
when used as a sub-panel
to add circuits to existing
service. The main breaker
protects the main entire
panel and can be used as
a service disconnect. The
branch breakers protect the
wires leading to individual
electrical loads such as
fixtures and outlets.

Loadcenter Construction
Eaton’s Type CH loadcenters
feature silver flash plated
copper bus in all interiors.
Fingers are rated 200A
throughout the CH line.
Therefore, the sum of the
handle ratings connected to
any one stab is limited to
200A maximum. NEMA 1
boxes are manufactured from
cold rolled 16 gauge sheet
steel. Raintight boxes are
manufactured from galvanized
steel. All boxes and trims are
finished using an electrostatic
powder coat, baked urethane
paint process.
Neutrals
Eaton’s Type CH loadcenters
feature three types of neutrals:
Factory-Bonded Split Neutral
Single-phase main circuit
breaker panels are supplied
with a factory-bonded twin
neutral. When used as a subpanel, the bonding strap should
be removed, and the bonding
screw should be reinstalled.
The bonded side is now the
ground, and the un-bonded
side is the neutral. When used
as a service entrance panel,
the unused neutral holes on
either side may be used for
terminating ground wires.

1.1
1

Insulated Split Neutral
Most single-phase main
lug panels (12 circuits and
greater) are supplied with a
twin neutral with an insulated
cross strap. These panels
are shipped in an un-bonded
state. For service entrance
applications, the neutral
must be bonded utilizing
the bonding strap supplied
with the panel. For sub-feed
applications, the panel may
be installed as is. Separate
ground bars are provided on
these panels.
Insulated/Bondable
Single Neutral
When a panel is supplied with
a single neutral, it arrives from
the factory in an “unbonded”
state. All that is required to
bond the neutral in a service
entrance application is to
loosen the bonding screw and
the neutral screw directly
beside it, insert the bonding
strap into the neutral bar, and
re-tighten both connections.
The single neutral can be
moved by the contractor to
the other side of the panel, if
desired. In a service entrance
application, where the neutral
is bonded, unused neutral
connections may be used
for the termination of
equipment grounds.

Inboard Plug-On Neutral
Code changes and higher
safety standards are
leading to more arc fault
circuit interrupter (AFCI)
installations. With the
electrical contractor in mind,
Eaton has revolutionized the
way Combination AFCIs are
installed with the Plug-on
Neutral line of loadcenters
and breakers. This unique
product solution enables the
contractor to connect the
breaker directly to the neutral
bar, eliminating the need for
wiring a pigtail.
Grounds
In service entrance
applications where the
neutral is bonded, unused
neutral holes may be used
for terminating ground
conductors. In sub-feed
panels, the neutral must be
isolated (non-bonded), and
ground wires must be
terminated on a separate
ground bar.

1
1
1
1
1
1
1
1
1
1
1
1
1

The Factory-Bonded Split
Neutral panels have sufficient
terminations for both ground
and neutral conductors. The
Insulated Split Neutral panels
are supplied with a separate
factory-installed ground bar.
Insulated/Bondable Single
Neutral panels are supplied
without a ground bar (unless
otherwise noted), and ground
bar kits if needed must be
purchased separately.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

3

1.1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Type CH Loadcenter
“Tangential” Center Knockout
For easier installation

Extra 1.5-Inch (38.1 mm)
Knockout for Bundling
Provides for easier installation,
less installation time.

Single Keyhole Mounting
Just one keyhole at top and bottom
for easier mounting
and leveling.

Top or Bottom Feed
■ Straight-in wiring saves labor
and material
■ Only one panel for either application—
no modifications necessary

Unique Sandalwood Finish
Immediately recognizable,
aesthetically appealing, scratch
resistant powder coating.

1
1
1
1

Separately Packaged Covers
■ Full line of “true” surface and
combination covers.
■ Built-in flush leveling
feature.
■ Choice of circuit
identification by breaker labels or
circuit directory.

Commercial Grade Main Breaker
■ 35 kAIC series rated main breaker in
150 and 200A loadcenters
■ 42 and 100 kAIC series ratings
available

1
1

Drywall Marking on Enclosure
Indicates proper mounting
depth for flush applications.

Neutral Design
(for styles as indicated)
■ Bonding strap is easily removable
for sub-panel applications
providing a ground and neutral
■ Factory-bonded for service entrance
applications providing a split neutral
■ Ample additional 2/0 lugs provided;
no kits necessary
■ 200% size neutral

1
1
1

One-Piece Silver Flash Plated
Copper Bus
Provides superior conductivity
throughout the entire product line.

1
1
1
1
1
1
1
1
1

Steel Backpan
■ Provides positive, reliable
breaker mounting
■ One-piece designed for stability
Convertible Styles Available
■ Uses field installable main breaker
or main lug kits
■ Flexible inventory—same breaker
is used in loadcenter and circuit breaker
enclosures

Warranty
The minimum warranty
for residential loadcenters,
breakers and surge protection
devices shall be as follows:

1

●

1

●

1

Lifetime loadcenter
warranty
Lifetime warranty on all
arc fault circuit interrupting
circuit breakers

Improved Endwall Knockouts
Larger KOs are balanced to enhance
installed appearance and to ease use
of existing wiring.

●

●

●

Lifetime warranty on
CHSPULTRA including
$5000 connected load
warranty
Lifetime warranty on all
thermal-magnetic and
GFCI branch circuit
breakers
1-year warranty on plug-in
surge protection device
(CHSURGE)

1
1
1
4

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Standards and Certifications
UL® Listings
All Eaton Type CH loadcenters
are listed under UL File E8741.
Neutral and Ground Terminals
The standard terminals on
grounds and neutrals are rated
to accept (3)—#14–#10 Cu/Al
or (1)—#14–4 wires. For larger
cables, add-on neutral lugs
may be ordered from the
Accessories on Page 25.
Note: NEC® allows only one
current carrying conductor
per hole on neutrals unless
otherwise noted.

Bottom-Fed Loadcenters
When the power cable is
brought into the loadcenter
from below the panel; then
the main lug panels, and
single-phase, 225A and
below, loadcenters can be
rotated 180 degrees to allow
straight-in wiring of power
cables to the main terminals.
Because the CSR main circuit
breaker handle operates
horizontally, the orientation of
the main circuit breaker
handle is consistent with the
requirements of NEC Article
240-81.
Gutter Splicing
Loadcenters are not UL listed
as wiring troughs. Therefore,
gutter splicing of riser cables
to tap off to the main device
is not permitted. Refer to
NEC Article 373-8.

1
Fire Rating
Due to the numerous
openings in both loadcenter
boxes and trims, they should
not be mounted in firewalls.
There is no approval method
for sealing the enclosures for
this application.
Date Code
The date of manufacture of
each loadcenter is printed on
the outside of the carton as
well as inside the loadcenter.
On the carton, the date code
is printed on the end carton
label. In the loadcenter, the
date code is located on the
small white label located on
the right side wall (with the
main device on top).
The date code is in the
following format: F # # # &.
The “F” is the numeric code
for the Lincoln, IL plant,
and the three numbers
are the year and week of
manufacture e.g., 023. The
“&” sign at the end signifies
the decade of the 2000s.
Therefore, the date code
F023& would indicate
that the product was
manufactured in the 23rd
week of 2000. The 1980s
are represented by a
“+” sign and the 1990s
are represented by a “=”
at the end of the code.

Plug-On Type CH Breakers
Quick-make, quick-break
switch mechanism combined
with inverse time element
tripping operation and tripfree handle design. Type CH
circuit breakers trip to the
OFF position eliminating
nuisance callbacks. The
thermal-magnetic trip curve
avoids nuisance tripping on
mild overloads while reacting
almost instantaneously
to severe short-circuit
conditions. Multipole
breakers have internal
common trip connection
to operate all poles
simultaneously. Handles
are marked with ON-OFF
indication and ampere rating
of the breaker. Type CH
breakers meet UL Standard
489, NEMA standards, and
Federal Spec Classification
W-C 375 b/Gen. They are
UL listed under File Number
E11713, E8741, E3624 and
E51287: and CSA® certified
file number LR87196, except
Type CHT breakers.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Type CH Circuit Breaker Ratings
Single- and double-pole CH
breakers rated 15 and 20A
have low instantaneous
magnetic trip levels. The 15
and 20A breakers with “HM”
suffix have high magnetic trip
settings recommended for
circuits with inherently high
inrush currents. All Type CH
breakers are marked for
heating, air conditioning
and refrigeration (HACR)
equipment application.
Single-pole 15–20A breakers
are also suitable for switching
duty (SWD). Shunt trip coils
operate on 120 Vac and
require one additional pole
space per breaker.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

5

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Catalog Number Selection

1

Loadcenters 100–225A and 12–42 Circuits

CH 42 B

1
1

LC Type
Type CH 3/4-inch (19.1 mm)
branch circuit breakers

1

Number of Circuits
Selection circuits
2
20
4
22
8
24
12
28
14
30
16
32
18
42

1
1
1
1

L
B
N
H

200

K

Bus Amperes
40
150
70
200
100
225
125

Main Device
= Main lug only
= Main breaker
= Convertible
= High AIC
main breaker

Construction
Blank = Standard
PN = Plug-on neutral

Phases
Blank = Single-phase
3
= Three-phase

1
1

Box Sizes
B
C
D
E
G
J
K
L
R = Outdoor (no cover)
Accessories
Blank = Standard
EC
= Surge ready
SUR = Surge factory
installed

Indoor Covers Ordered Separately

1

CH

8 K F

1
Type CH

1

Factory Options
Blank = Standard
SUR = Surge/surge ready

1

Mounting
F = Combination
flush/surface
S = Surface

Accessories
Blank = Standard
M
= Mechanical interlock

Box Size
Indicated in loadcenter
catalog number

1
1

Loadcenter
Cover Series

Note: All combinations are not valid, refer to the catalog section.

1
1
1
1
1
1
1
1
1
1
1
1
1
6

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Product Selection

1

Single-Phase—Main Circuit Breaker Loadcenters—10/35 kAIC
CH42B200K

1

Single-Phase Three-Wire—120/240 Vac—Factory-Bonded Split Neutral (Unless Otherwise Noted)
Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
of Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter 
Catalog Number

Loadcenter Cover
Catalog Number
Combination 
Surface

CH
10 kAIC

100

14

Indoor

B

#6–1/0

CH14B100B 

CH8BF

CH8BS

14

Outdoor

B

#6–1/0

CH14B100R 

—

—

18

Indoor

C

#6–1/0

CH18B100C 

CH8CF

CH8CS

18

Outdoor

C

#6–1/0

CH18B100R 

—

—

22

Indoor

C

#6–1/0

CH22B100C 

CH8CF

CH8CS

22

Outdoor

C

#6–1/0

CH22B100R 

—

—

30

Indoor

D

#6–1/0

CH30B100D 

CH8DF

CH8DS

30

Outdoor

D

#6–1/0

CH30B100R 

—

—

22

Indoor

C

#6–1/0

CH22B125C 

CH8CF

CH8CS

22

Outdoor

C

#6–1/0

CH22B125R 

—

—

30

Indoor

D

#6–1/0

CH30B125D 

CH8DF

CH8DS

30

Outdoor

D

#6–1/0

CH30B125R 

—

—

—

—

CH8EF

CH8ES

125

CSH
35 kAIC 

150

200

8

Outdoor

E

#2–300 kcmil

CH8B150RF

24

Indoor

E

#2–300 kcmil

CH24B150E 


24

Outdoor

E

#2–300 kcmil

CH24B150R

—

—

32

Indoor

J

#2–300 kcmil

CH32B150J 

CH8JF

CH8JS

32

Outdoor

J

#2–300 kcmil

CH32B150R 

—

—

8

Outdoor

E

#2–300 kcmil

CH8B200RF 	

—

—

24

Indoor

E

#2–300 kcmil

CH24B200E 

CH8EF

CH8ES

24

Outdoor

E

#2–300 kcmil

CH24B200R 

—

—

32

Indoor

J

#2–300 kcmil

CH32B200J 

CH8JF

CH8JS



32

Outdoor

J

#2–300 kcmil

CH32B200R

—

—

42

Indoor

K

#2–300 kcmil

CH42B200K 

CH8KF

CH8KS

42

Outdoor

K

#2–300 kcmil

CH42B200R 

—

—

24

Indoor

E

#2–300 kcmil

CH24B200E 

CH8EF

CH8ES

24

Outdoor

E

#2–300 kcmil

CH24B200R 

—

—

32

Indoor

J

#2–300 kcmil

CH32B200J 

CH8JF

CH8JS

32

Outdoor

J

#2–300 kcmil

CH32B200R 

—

—



42

Indoor

K

#2–300 kcmil

CH42B200K

CH8KF

CH8KS

42

Outdoor

K

#2–300 kcmil

CH42B200R 

—

—

32

Indoor

J

#2–300 kcmil

CH32B225J 

CH8JF

CH8JS

32

Outdoor

J

#2–300 kcmil

CH32B225R 

—

—

42

Indoor

K

#2–300 kcmil

CH42B225K 

CH8KF

CH8KS

42

Outdoor

K

#2–300 kcmil

CH42B225R 

—

—

300

42

Indoor

PM

(2) 3/0–250 kcmil

CH42PM300

CH7PMF 

CH7PMS

400

42

Indoor

PM

(2) 3/0–250 kcmil

CH42PM400

CH7PMF 

CH7PMS

225

DK
10 kAIC

	

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
 All main circuit breaker loadcenters are listed for use as service entrance equipment.
 Ground bar kits priced separately. See Page 26.
 Combination style covers may be used in surface or flush applications.
 Loadcenters are factory-bonded for service entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications.
 Can be top or bottom fed by rotating the enclosure and trim 180 degrees.
 Loadcenter contains single insulated/bondable neutral.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 26.
 35 kAIC series combination rating is obtained when Types CH, CHT and CHP branch breakers are used with CSH main.
	 Panel includes #4–300 kcmil feed-through lugs.
 This cover is for flush applications only (not combination).

1
1
1
1
1

Box sizes Pages 41 and 42.

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

7

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Single-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—42/100 kAIC
Single-Phase Three-Wire—120/240 Vac—Factory-Bonded Split Neutral (Unless Otherwise Noted)

1

Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter 
Catalog Number

Loadcenter Cover
Catalog Number
Combination 

1

CHB4
42 kAIC 

100

20

Indoor

C

#6–1/0

CH20H100C 

CH8CF

CH8CS

20

Outdoor

C

#6–1/0

CH20H100R 

—

—

28

Indoor

D

#6–1/0

CH28H100D 

CH8DF

CH8DS

28

Outdoor

D

#6–1/0

CH28H100R 

—

—

32

Indoor

L

#2/0–300 kcmil

CH32H150L 

CH8LF

CH8LS

32

Outdoor

L

#2/0–300 kcmil

CH32H150R 

—

—

1
1

CHH
100 kAIC 

1

150

Surface

32

Indoor

L

#2/0–300 kcmil

CH32H200L 

CH8LF

CH8LS

1

32

Outdoor

L

#2/0–300 kcmil

CH32H200R 

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H200L 

CH8LF

CH8LS

1

42

Outdoor

L

#2/0–300 kcmil

CH42H200R 

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H225L 

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42H225R 

—

—

200

225

1
1
1
1
1

Notes
 All main circuit breaker loadcenters are listed for use as service entrance equipment.
 Combination style covers may be used in surface or flush applications.
 Series rated for 42 kAIC with all Types CH, CHT and CHP breakers.
 Loadcenters are factory-bonded for service entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications.
 Loadcenter can be top or bottom fed by rotating the enclosure and trim 180 degrees.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 26.
 Loadcenter contains single insulated/bondable neutral.
 Series rated for 100 kAIC with all Types CH, CHT and CHP breakers.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Single-Phase—Main Lug Loadcenters

1
1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral

Surface

Outdoor

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Space

40

Poles

Enclosure
Type

Type of Trim
(Included)

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

2

4

Indoor

Surface (no door)

5

#14–6

CH2L40SP 

2

4



2

4

1
1



Outdoor

—

5R

#14–6

CH2L40RP

Indoor

Flush (no door)

5

#14–6

CH2L40FP 

1
1
1

Flush

Outdoor

70

2

4

Indoor

Surface (no door)

5

#14–2

CH2L70SP 

2

4

Outdoor

—

5R

#14–2

CH2L70RP 

2

4

Indoor

Flush (no door)

5

#14–2

CH2L70FP 

1
1
1

Surface (No Door)

Flush (No Door)

125

2

4

Indoor

Surface (no door)

6

#14–1/0

CH2L125SP 

2

4

Outdoor

—

6R

#14–1/0

CH2L125RP 

2

2

Outdoor

—

—

#14–1/0

CH2L125RSE2P 

2

4

Indoor

Flush (no door)

6

#14–1/0

CH2L125FP 

4

8

Indoor

Surface (no door)

7

#14–1/0

CH4L125SP 

4

8

Outdoor

—

7R

#14–1/0

CH4L125RP 

4

8

Indoor

Flush (no door)

7

#14–1/0

CH4L125FP 

Indoor

Surface (no door)

7

#6–1/0

CH8L125SP 

Outdoor

—

7R

#6–1/0

CH8L125RP 

Indoor

Flush (no door)

7

#6–1/0

CH8L125FP 



8

16

8

16 

8



16

1
1
1
1
1
1
1
1

Outdoor

1
1
1
Notes
 Requires the use of Type CHNT breakers.
 Ground bar kits priced separately, see Page 26.
– For 2/4 circuit loadcenters use Type GBK5 or GBK520 ground bar
– For 4/8 and 8/16 circuit loadcenters use Type GBK10 ground bar
– Ground bars mount to the left side wall of the enclosure for the 4/8 and 8/16 circuit loadcenters
 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 26.
 For use as service entrance applications only.
 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/AI.
 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are
provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
 Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting
and appliance panelboard (see Article 408.34 of the NEC).
Box sizes Pages 41 and 42.

1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

9

1.1
1

CH42L225G

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Single-Phase Three-Wire—120/240 Vac—Twin Neutral—Factory-Installed Ground Bar
Main
Ampere
Rating

1

125

1
1
1
1
1

150

1
1
200

1
1
1

225

1

Maximum Number
3/4-Inch (19.1 mm)
Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

Loadcenter Cover
Catalog Number
Combination
Surface

12

Indoor

B

#6–2/0

CH12L125B 

CH8BF

CH8BS

12

Outdoor

B

#6–2/0

CH12L125R 

—

—

16

Indoor

B

#6–2/0

CH16L125B 

CH8BF

CH8BS

—

—



16

Outdoor

B

#6–2/0

CH16L125R

20

Indoor

C

#6–2/0

CH20L125C 

CH8CF

CH8CS

20

Outdoor

C

#6–2/0

CH20L125R 

—

—

24

Indoor

C

#6–2/0

CH24L125C 

CH8CF

CH8CS

24

Outdoor

C

#6–2/0

CH24L125R 

—

—

24

Indoor

D

#4–300 kcmil

CH24L150D 

CH8DF

CH8DS

24

Outdoor

D

#4–300 kcmil

CH24L150R 

—

—

32

Indoor

D

#4–300 kcmil

CH32L150D 

CH8DF

CH8DS

—

—



32

Outdoor

D

#4–300 kcmil

CH32L150R

12

Indoor

D

#4–300 kcmil

CH12L200D 

CH8DF

CH8DS

12

Outdoor

D

#4–300 kcmil

CH12L200R 

—

—

16

Indoor

D

#4–300 kcmil

CH16L200D 

CH8DF

CH8DS

16

Outdoor

D

#4–300 kcmil

CH16L200R 

—

—

24

Indoor

D

#4–300 kcmil

CH24L225D 

CH8DF

CH8DS

24

Outdoor

D

#4–300 kcmil

CH24L225R 

—

—

32

Indoor

D

#4–300 kcmil

CH32L225D 

CH8DF

CH8DS

—

—



1

32

Outdoor

D

#4–300 kcmil

CH32L225R

42

Indoor

G

#4–300 kcmil

CH42L225G 

CH8GF

CH8GS

1

42

Outdoor

G

#4–300 kcmil

CH42L225R 

—

—

42

Indoor

P

(2) 1/0–300 kcmil
(1) 750 kcmil

CH42PL400 

CH7PF 

CH7PS

400

1

Notes
 Suitable for use as service equipment when not more than six disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 26.
 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit
catalog number CH125RB.
 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB.
The breaker cannot be a Type CH.
 This cover is for flush application only (not combination).

1
1
1
1

Box sizes Pages 41 and 42.

1
1
1
1
1
1
1
1
1
1
10

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Three-Phase—Main Circuit Breaker Loadcenters—10 kAIC

CH42B3200L

1
1

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral
Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter 
Catalog Number

Loadcenter Cover
Catalog Number
Combination
Surface

CC
10 kAIC

150

30

Indoor

L

#1–4/0

CH30B3150L

CH8LF

CH8LS

200

225

400



30

Outdoor

L

#1–4/0

CH30B3150R

—

—

30

Indoor

L

#2/0–300 kcmil

CH30B3200L

CH8LF

CH8LS

1
1
1

30

Outdoor

L

#2/0–300 kcmil

CH30B3200R 

—

—

42

Indoor

L

#2/0–300 kcmil

CH42B3200L

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42B3200R 

—

—

30

Indoor

L

#2/0–300 kcmil

CH30B3225L

CH8LF

CH8LS

30

Outdoor

L

#2/0–300 kcmil

CH30B3225R 

—

—

42

Indoor

L

#2/0–300 kcmil

CH42B3225L

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42B3225R 

—

—

42

Indoor

PM

(2) 3/0–350 kcmil

CH424PM400

CH7PMF 

CH7PMS

1
1
1
1
1
1

Three-Phase—Main Lug Loadcenters

1
Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral
Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Spaces

Poles

Enclosure
Type

Type of Trim
Included

125

6

12 

Indoor

6

12



6

12 

1

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

1

Surface no door

7

#14–1/0

CH6L3125SP 

1

Outdoor

—

7R

#14–1/0

CH6L3125RP 

Indoor

Flush no door

7

#14–1/0

CH6L3125FP 

1

Notes
 All main circuit breaker loadcenters are listed for use as service entrance equipment.
 For ground bar kits, see Page 26.
 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page 26.
 This cover for flush application only (not combination).
 Requires the use of CHNT breakers.
 Suitable for use as service equipment when not more than two service disconnecting means are provided or when not more than six service disconnecting means are
provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
 Ground bar kits priced separately, see Page 26.
– Use GBK10 ground bar
– Ground bars mount to the left side wall of the enclosure.
Box sizes Pages 41 and 42.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

11

1.1
1
1
1

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

Loadcenter Cover
Catalog Number
Combination

Surface

125

12

Indoor

B

#6–2/0

CH12L3125B 

CH8BF

CH8BS

12

Outdoor

B

#6–2/0

CH12L3125R 

—

—

18

Indoor

C

#6–2/0

CH18L3125C 

CH8CF

CH8CS

—

—

1
1

150

225

1
1
1
1

Type CH Loadcenters and Circuit Breakers

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac—Insulated/Bondable Neutral

1
1

Loadcenters and Circuit Breakers

400



18

Outdoor

C

#6–2/0

CH18L3125R

24

Indoor

C

#6–2/0

CH24L3125C 

CH8CF

CH8CS

24

Outdoor

C

#6–2/0

CH24L3125R 

—

—

30

Indoor

D

#4–300 kcmil

CH30L3150D 

CH8DF

CH8DS

30

Outdoor

D

#4–300 kcmil

CH30L3150R 

—

—

24

Indoor

D

#4–300 kcmil

CH24L3225D 

CH8DF

CH8DS

24

Outdoor

D

#4–300 kcmil

CH24L3225R 

—

—

30

Indoor

D

#4–300 kcmil

CH30L3225D 

CH8DF

CH8DS

—

—



30

Outdoor

D

#4–300 kcmil

CH30L3225R

42

Indoor

G

#4–300 kcmil

CH42L3225G 

CH8GF

CH8GS

42

Outdoor

G

#4–300 kcmil

CH42L3225R 

—

—

42

Indoor

P

(2) 1/0–300 kcmil
(1) 750 kcmil

CH424PL400 

CH7PF 

CH7PS

1
1
1
1
1
1

Three-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—100 kAIC

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral
Main
Breaker
Type

Main
Ampere
Rating

CHH
100 kAIC 

200

1
225

1
1
1
1
1
1
1

Maximum Number
3/4-Inch (19.1 mm)
of Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter
Catalog Number 	

Loadcenter Cover
Catalog Number
Combination

Surface

30

Indoor

L

#2/0–300 kcmil

CH30H3200L

CH8LF

CH8LS

30

Outdoor

L

#2/0–300 kcmil

CH30H3200R 

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H3200L

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42H3200R 

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H3225L

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42H3225R 

—

—

Notes
 Ground bar Type GBK14 is installed.
 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number Type CH125RB. Suitable for
use as service equipment when not more than six service disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 26.
 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down kit catalog number Type CH125RB.
 Ground bar Type GBK21 is installed.
 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB. The breaker cannot be a Type CH.
 For ground bar kits, see Page 26.
 This cover is for flush application only (not combination).
	 All main circuit breaker loadcenters are listed for use as service entrance equipment.
 Ground bar kits priced separately.
 100 kAIC series combination rating is obtained when Types CH and CHP branch breakers are used with CHH main.
 Rainproof loadcenters are furnished with hub closure plates.

1
1
1
1
1
12

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Convertible Loadcenters MCB or MLO—Base Units and Main Devices—10/35 kAIC
Complete assembly consists of: loadcenter, cover, and either main breaker kit or main lug kit.

1
1

Indoor—Single-Phase—Three-Wire—120/240V—Factory-Bonded Split Neutral—Top or Bottom Feed
Maximum
Main Ampere
Rating

Maximum
Number of
Single Poles

Box
Size

Loadcenter Box
and Panel
Catalog Number 

125

22

C

CH22N125C

Loadcenter Cover
Catalog Number
Combination

Surface

Main Lug Kit
Wire
Catalog
Size
Number

CH8CF

CH8CS

#10–1/0

CHL125N

1

Main Breaker Kit
kAIC
Wire
Rating
Size

Catalog
Number

10

CH2100N 

#10–1/0

1
1

CH2125N 
200

32

J

CH32N200J

CH8JF

CH8JS

#4–300
kcmil

CHL225N

25

1

CSH2125N 

#2–300
kcmil

CSH2150N 

1

CSH2175N 

1

CSH2200N 
225

42

K

CH42N225K

CH8KF

CH8KS

#4–300
kcmil

CHL225N

25

CSH2125N 

#2–300
kcmil

1

CSH2150N 
CSH2175N



1

CSH2200N 
CSH2225N 

1
1

Outdoor—Single-Phase—Three-Wire—120/240V—Insulated/Bondable Neutral
Maximum
Main Ampere
Rating

Maximum
Number of
Single Poles

Box
Size

Loadcenter Box
and Panel
Catalog Number 

Main Lug Kit
Wire
Catalog
Size
Number

Main Breaker Kit
kAIC
Wire
Rating
Size

200

8

E

CH8N200RF 

#4–300 kcmil

25

CHL225N

1
Catalog
Number

1

#2–300 kcmil CSH2125N

1

CSH2150N
CSH2175N

1

CSH2200N
125

22

C

CH22N125R



#10–1/0

CHL125N

10

#10–1/0

CH2100N



1

CH2125N 
200

32

CH32N200R 

J

#4–300 kcmil

CHL225N

25

1

#2–300 kcmil CSH2125N 
CSH2150N 

1

CSH2175N 
CSH2200N 
225

42

CH42N225R 

K

#4–300 kcmil

CHL225N

25

1

#2–300 kcmil CSH2125N 
CSH2150N



1

CSH2175N 

1

CSH2200N 
CSH2225N 

1

Notes
 Panel does not include main. Order main breaker or main lug kit separately.
 Loadcenters are factory-bonded for service entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications.
 Hold-down kit included.
 35 kAIC series combination rating is obtained when Types CH, CHT and CHP branch breakers are used with CSR main.
 CSH breakers include line lugs only as standard.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 26.
 Includes feed-through lugs for both phase and neutral conductors.

1
1
1

Interrupting rating depends on main circuit breaker selected.

1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

13

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Spa Panels

1

CH Spa Panel

1
1
1
1
1
1
1

Quick-Pro SM
All you need to know to save time
and make more money. Specified
on certain Eaton products, the
Quick-Pro symbol allows for
immediate recognition of products
that are designed for straightforward
installation. When you see Quick-Pro,
you know you can install quickly—
sometimes up to 50% less than the
usual installation time—and move
onto your next job.

Single-Phase Three-Wire—120/240 Vac Insulated/Bondable Neutral—
Factory-Installed Ground Bar
Main
Ampere
Rating

Circuit
Breaker
Included

Enclosure
Type

Type
of Trim
Included

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Catalog
Number

30

CH230GF

Outdoor

—

5R

#14–1/0

CH30SPA 

40

CH240GF

Outdoor

—

5R

#14–1/0

CH40SPA 

50

CH250GF

Outdoor

—

5R

#14–1/0

CH50SPA 

60

CH260GF

Outdoor

—

5R

#14–1/0

CH60SPA 

Notes
 Includes a CH230GFI breaker, factory installed, and two extra circuits for convenience.
 Includes a CH240GFI breaker, factory installed, and two extra circuits for convenience.
 Includes a CH250GFI breaker, factory installed, and two extra circuits for convenience.
 Includes a CH260GFI breaker, factory installed, and two extra circuits for convenience.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
14

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Single-Phase and Three-Phase Circuit Breaker Unit Enclosures—10/35 kAIC

Circuit Breaker
Unit Enclosures

1
1

Type ECB Circuit Breaker Unit Enclosure—Order Type CSR Circuit Breaker Separately—Unit Enclosure
Includes Lug Tree Kit
Main Ampere
Rating

Unit Enclosure
Type

Mounting

Type of
Circuit Breaker

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

1
1

Single-Phase Three-Wire—240 Vac Maximum
150

Outdoor

—

CSR (included) 



ECB150RB 

200

Outdoor

—

CSR (included) 



ECB200RB 

225





ECB225F

1



Indoor

Flush

CSR

Indoor

Surface

CSR 



ECB225S 

Outdoor

—

CSR 



ECB225R 

1
1
1

CSH2200N

Type CSH Circuit Breakers 120/240 Vac—
35 kAIC For Use in Type ECB Unit
Enclosures

Wire Data
Wire/Application

Maximum
Wire Size

Maximum
Ampere Rating

1
1

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C
for Line Terminals

Two-Pole Breakers
35 kAIC
Catalog Number

Aluminum—standard

250 kcmil

200

Aluminum—service entrance

250 kcmil

225

100

#2–300 kcmil

CSH2100N

Copper—standard and service entrance

250 kcmil

225

125

#2–300 kcmil

CSH2125N

150

#2–300 kcmil

CSH2150N

1

175

#2–300 kcmil

CSH2175N

200

#2–300 kcmil

CSH2200N

225

#2–300 kcmil

CSH2225N

Notes
 CSR2150N factory-installed circuit breaker.
 CSR2200N factory-installed circuit breaker.
 Order circuit breaker separately.
 Wire size is determined by the circuit breaker installed in enclosure.
Maximum wire size and ampere rating is determined by Wire Data table above.
 Rainproof panels are furnished with hub closures plates. For rainproof hubs,
refer to Page 26.
 One ground lug accepting (1) #14 –#2 is factory installed. Also, there are pre-drilled
holes to accept a GBK5 ground bar.
 Approved for service entrance.
 Add suffix indicated to end of breaker catalog number.
Box sizes Pages 41 and 42.

1

Shunt Trips
Type

Volts

Catalog Number
Suffix Adder 

CSH

12

SR12

CSH

24

SR24

CSH

120

SR01

1
1
1
1
1
1
1
1

CSR Lug Tree Kit For Replacement
Purposes Only For Use in Type ECB
Unit Enclosures
Ampere
Rating
225

Description

1

Wire Size Range
Cu/Al 60°C or 75°C Catalog
for Line Terminals Number

For use on 125,
#2–300 kcmil
150, 175, 200 and
225A CSR breakers

1

MCBK225

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

15

1.1
1
1
1

Type CH Loadcenters and Circuit Breakers

Type ECC Circuit Breaker Unit Enclosure—Order Type CC Circuit Breaker Separately
Main
Ampere Rating

Unit
Enclosure Type

Mounting

Circuit Breaker
Type

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

Flush

CC 



ECC225F 

CC





ECC225S 

CC





ECC225R 

Single-Phase Three-Wire—240 Vac Maximum
225
225

1

Loadcenters and Circuit Breakers

225

Indoor
Indoor

Surface

Outdoor

—

1
1
1
1

Type CC Circuit Breakers 240 Vac—10 kAIC For Use in Type
ECC Unit Enclosures
Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C
for Line Terminals

Type CC
10 kAIC
Catalog Number

Two-Pole
100

#4–4/0

CC2100

125

#4–4/0

CC2125

150

#4–4/0

CC2150

175

#2/0–300 kcmil

CC2175

1

225

#2/0–300 kcmil

CC2200

225

#2/0–300 kcmil

CC2225

1

Three-Pole
100

#4–4/0

CC3100

125

#4–4/0

CC3125

150

#4–4/0

CC3150

175

#2/0–300 kcmil

CC3175

200

#2/0–300 kcmil

CC3200

225

#2/0–300 kcmil

CC3225

1
1

1
1
1

Wire Data
Wire/Application

Maximum
Wire Size

Maximum
Ampere Rating

Aluminum—standard

250 kcmil

200

Aluminum—service entrance

250 kcmil

225

Copper—standard and service entrance

250 kcmil

225

Notes
 Order circuit breaker separately.
 Wire size is determined by the circuit breaker installed in enclosure. Maximum wire size
and ampere rating is determined by the Wire Data table above.
 One ground lug accepting (1) #14–#2 is factory installed. Also, there are pre-drilled holes to
accept a GBK5 ground bar.
 Approved for service entrance.
 Rainproof panels are furnished with hub closures plates. For rainproof hubs, refer to
Page 26.
Box sizes Pages 41 and 42.

1
1

Shunt Trips, Auxiliary and Alarm Contacts

1

Type

Volts

Catalog Number
Suffix Adder

CC

12 DC

SR12

CC

24 DC

SR24

CC

120 AC

SR01

1

CC

208 AC

SR08

CC

240 AC

SR02

1

Auxiliary Contact
—

AL1

—

CR1

Shunt Trip

1
1

CC (1) NO and (1) NC

1
1

Alarm Contact
CSR

1
1
1
1
1
1
16

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Technical Data and Specifications
General
A. The Contractor shall
furnish and install
loadcenters incorporating
circuit breakers of the
number, rating and type
as specified herein and
as shown on the
contract drawings.

Ratings
A. Loadcenters shall be
rated for 240 Vac and
shall have short-circuit
ratings as shown on the
drawings or as herein
scheduled, but not less
than 10,000 amperes
rms symmetrical.

B. The loadcenter and all
components shall be
designed, manufactured
and tested in accordance
with the latest applicable
standards of UL and
NEMA including:

B. Breakers shall be full
size and a minimum of
125A frame. Breakers
10 –125A trip size shall
take up the same pole
spacing.

4. Federal Spec
Classification W-C 375

C. Loadcenters shall be
labeled with a UL shortcircuit rating. When
series ratings are applied
with integral or remote
devices, a label shall be
provided. Series ratings
shall cover all trip ratings
of installed frames. It
shall state the conditions
of the UL series ratings
including:

5. UL 1699 — all fault
interrupting

1. Size and type of
upstream device.

Qualifications
A. The manufacturer of the
loadcenter shall be the
manufacturer of the
circuit breaker within the
load center. All breakers
shall be full size.

2. Branch devices that
can be used.

1. UL 67—standards for
panelboards
2. UL 50—standards for
cabinets and boxes
3. UL 489—standards for
molded case circuit
breakers

B. For the equipment
specified herein, the
manufacturer shall be
ISO® 9000 certified.
C. The manufacturer of
this equipment shall
have produced similar
electrical equipment
for a minimum period
of seven (7) years.
Manufacturers
A. Eaton

3. UL series short
circuit rating.
Construction
A. All interiors, with the
exception of the branch
circuit breakers shall be
completely factory
assembled with main
breakers, main lugs or
no main device.
B. Interiors shall be so
designed that circuit
breakers can be replaced
without disturbing
adjacent units and
without removing the
main bus connectors and
shall be so designed that
circuits may be changed
without machining,
drilling or tapping.
C. Physical means must
be provided to prevent
the installation of more
overcurrent devices than
that number for which
the enclosure was
designed. Full size
breakers are required.

Bus
A. Bus bars for the main and
cross connectors shall be
of silver flash plated
copper construction in
accordance with UL
standards. Bussing shall
be braced to 65 kAIC.
B. Neutral bussing shall
have a suitable lug for
each outgoing feeder
requiring a neutral
connection of same
ampacity as branch.
Wiring/Termination
A. All wire connectors and
terminals shall be of the
anti-turn solderless type
and suitable for copper
or aluminum wire of the
sizes indicated. All
connectors shall meet
the “Requirements
for Wire Connectors
and Soldering Lugs”
UL 486B.
B. All loadcenters where
marked shall be suitable
for use with 60/75°C
rated wire.
Circuit Breakers
A. Circuit breakers shall
be molded case type,
3/4-inch (19.1 mm) wide
per pole. Multipole circuit
breakers shall be of a
stack pole design to
provide electrical phase
isolation and have an
internal common trip.
B. Each pole of the circuit
breaker will have inverse
time delay overload and
instantaneous shortcircuit protection by
means of both thermal
and magnetic sensors.
Circuit breakers shall be
quick-make/quick-break.

D. All circuit breakers shall
be operated by a toggletype handle and multipole
circuit breakers shall have
an internal common trip
mechanism. The circuit
breakers shall incorporate
trip mechanisms that are
mechanically trip-free
from the handle. The
handle position shall
provide good visual
trip indication.
E. Contacts shall be of nonwelding silver alloy.
F. All branch breaker
handles shall be of a
different color than the
case of the breaker.

1
1
1
1
1
1
1
1
1

G. All terminals shall be
listed for use with copper
or aluminum conductors.
Terminals shall be of the
box lug design. The
terminals shall meet
UL 486B requirements
and shall be suitable for
use with either 60° or
75°C wire.
H. Breakers shall be SWD
rated and/or HACR rated
as required.
I. Arc fault interrupting
circuit breakers, (AFC),
shall be provided on all
15 and 20A single-phase
120/240 Vac circuits
except those indicated
as remote controlled
breakers. AFI breakers
shall be “Classified for
mitigating the effects of
arcing faults,” or
conforming to UL
Standard 1699 and as
defined by per article
210-12 Section A of the
1999 NEC Code.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

C. The circuit breaker
calibration shall not be
affected by environmental
changes in relative
humidity. Breakers
shall be calibrated
after assembly.

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1

1
1
1
1
1
1
17

1.1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Enclosures
A. Loadcenters shall have
NEMA 1 general purpose
or NEMA 3R rainproof
enclosures as indicated
on the drawings and
shall be surface or flush
mounted except where
noted.
B. For indoor applications,
enclosures shall be rated
NEMA 1. Enclosures
shall be manufactured
from cold-rolled codegauge sheet steel having
multiple knockouts
and painted per paint
specification. For outdoor
applications, enclosures
shall be rated NEMA 3R.
Enclosures shall be
manufactured from
galvanized steel which
shall be painted per the
painted as specified.
Enclosures shall be of
sufficient size to meet
or exceed NEC wire
bending space.

Finish
A. Boxes and trims shall
be finished with a
high scratch-resistant
aesthetically pleasing
finish. The finish shall
be polyurethane coating
electrostatically applied
to a thickness of 1.8 to
2 mils.
B. All loadcenters shall be
provided with provisions
for accepting a paintable
or wall paperable
decorator accessory
cover. Where loadcenters
are installed in living areas,
provide manufacturer
designed and tested
decorator cover kits.

C. The cover shall have an
easy adjustment feature
for flush applications.
D. Boxes shall be factory
assembled into a single
rigid structure.
E. Provide circuit breaker
marking labels and
directories.

1
1
1
1
1
1
1
1
1
1
1
1
18

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Contents

Surge Panel

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel
Technical Data and Specifications . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Analyzer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
20
21
22
24
25
29

1
1
1
1
1
1
1
1
1
1
1

Surge Panel
Product Description
Eaton’s Type CH Surge
Loadcenter includes a factorymounted and wired surge
suppressor device. There is
a knockout in the cover that
allows the user to view the
status indication lights on
the surge suppressor. The
CH Surge Loadcenter reduces
the surge current, helping
protect sensitive home
electronic equipment.
Save labor
by installing
a factorymounted surge
protective
device.
Factory-Installed
Surge Protection
●
Includes a CHSPULTRA
and a two-pole 15A
circuit breaker
●
Increases the
effectiveness of
surge protection due
to reduced lead length
●
A modified deadfront
allows for easy viewing
of indicating lights

1

Product Selection

1

Surge Installed Loadcenters

1

Type

Number
of Circuits

Loadcenter
Catalog Number

Loadcenter Cover
Catalog Number
Combination

Surface

Convertible

42

CHSUR42N225L 

CHSUR8LF

CHSUR8LS

225

Convertible 

42

CHSUR42L225L2 

CHSUR8LF

CHSUR8LS

200

Main breaker

42

CHSUR42B200L2 

CHSUR8LF

CHSUR8LS

225

Convertible

32

CHSUR32N225K 

CHSUR8KF

CHSUR8KS

225

Convertible 

32

CHSUR32L225K 

CHSUR8KF

CHSUR8KS

200

Main breaker

32

CHSUR32B200K

CHSUR8KF

CHSUR8KS

150

Main breaker

32

CHSUR32B150K

CHSUR8KF

CHSUR8KS

100

Main breaker

32

CHSUR32B100K 

CHSUR8KF

CHSUR8KS

125

Convertible 

24

CHSUR24L125E 

CHSUR8EF

CHSUR8ES

100

Main breaker

24

CHSUR24B100E 

CHSUR8KF

CHSUR8KS

200

Convertible

40/40

BRSUR4040N200

Cover included

200

Main lug

40/40

BRSUR4040L200

Cover included

200

Main breaker

40/40

BRSUR4040B200

Cover included

Ampere
Rating
225

200

Convertible

30/40

BRSUR3040N200

Cover included

200

Main lug

30/40

BRSUR3040L200

Cover included

200

Main breaker

30/40

BRSUR3040B200

Cover included

1
1
1
1
1
1
1
1
1
1
1

Notes
 Order cover separately.
 With main lugs installed.

1
1

Surge Ready
Provides a mounting
provision for CHSPULTRA
●
A modified deadfront
allows for easy viewing
of indicating lights
●

1
1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

19

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Surge Ready Loadcenters (provision only, CHSPULTRA and breaker not included)
Number
of Circuits

Loadcenter
Catalog Number 

Loadcenter Cover Catalog Number
Combination
Surface

Convertible

42

CHEC42N225L

CHSUR8LF

Convertible 

42

CHEC42L225L

CHSUR8LF

CHSUR8LS

200

Main breaker

42

CHEC42B200L

CHSUR8LF

CHSUR8LS

225

Convertible 

32

CHEC32L225K

CHSUR8KF

CHSUR8LS

1

225

Convertible

32

CHEC32N225K

CHSUR8KF

CHSUR8LS

200

Main breaker

32

CHEC32B200K

CHSUR8KF

CHSUR8LS

1

150

Main breaker

32

CHEC32B150K

CHSUR8KF

CHSUR8LS

100

Main breaker

32

CHEC32B100K

CHSUR8KF

CHSUR8LS

125

Convertible 

24

CHEC24L125E

CHSUR8EF

CHSUR8LS

100

Main breaker

24

CHEC24B100E

CHSUR8EF

CHSUR8LS

1
1
1

1
1
1

Ampere
Rating

Type

225
225

Main Breaker Kits

CHSUR8LS

Main Lug Kits

1

Maximum Main Ampere Rating

Catalog Number

Maximum Main Ampere Rating

Catalog Number

100

CSH2100N

125

CHL125N

1

150

CSH2150N

225

CHL225N

200

CSH2200N

225

CSH2225N

1
1
1
1
1
1
1
1

Technical Data and Specifications
Ratings
●
Loadcenter
●
35 kAIC main breaker, main lug only, and convertible
main breaker/main lug
●
Factory installed or provision for field-installed
surge suppressor
●
Top or bottom feed
●

1
1

Surge suppressor (CHSPULTRA)
●
Total joules: 3500 joules
●
Maximum surge current: 175,000A
●
Per phase (L-N/L-G) surge current: 75,000A
●
Warranty: lifetime
●
Connected equipment warranty: $75,000

1
1
1

Notes
 Order cover separately.
 With main lugs installed.

1
1
1
1
1
1
20

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Contents

Renovation Panel

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Analyzer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
19
22
24
25
29

1
1
1
1
1
1
1
1
1
1
1

Type CH Renovation
Loadcenter
Product Description
Eaton’s Renovation
Loadcenter is designed
for the service contractor.
With the addition of a fivecircuit terminal block factory
mounted in the top left corner
of the loadcenter, the service
contractor can terminate
short-circuit wires instead of
having to use expensive wire
nuts. Also, the Renovation
Loadcenter incorporates a
twin-stacked neutral design
that places the neutral and
ground terminations higher in
the loadcenter. Both of these
features were added without
increasing any size from a
standard loadcenter. These
features will eliminate the
need for wire nuts and make
for a much neater installation.
There is a provision to field
mount a second five-circuit
terminal block (RN5TB) in
the top right corner of the
loadcenter. Choose amongst
Eaton’s Type CH breaker
family for use in the
Renovation Panel.

1
Product Selection

1

Single-Phase—Main Circuit Breaker Loadcenters 35 kAIC 

1

Single-Phase, Three-Wire—120/240 Vac—Factory-Bonded Stacked
Split Neutral

1

Box
Size

Wire Size
Range
Cu/Al
60 or 70ºC
for Main
Breakers

Loadcenter
Catalog
Number

Combination

Surface

Cover Catalog
Number 

Main
Breaker
Type

Main
Ampere
Rating

Max.
Number
3/4-Inch
(19.1 mm)
of Poles

CH

100

20

Indoor

C

#6–1/0

CH22B100CRN

CH8CFF

CH8CS

CSH

150

32

Indoor

J

#2–300 kcmil

CH32B150JRN

CH8JF

CH8JS

CSH

200

32

Indoor

J

#2–300 kcmil

CH32B200JRN

CH8J

CH8JS

CSH

200

42

Indoor

K

#2–300 kcmil

CH42B200KRN

CH8KF

CH8KS

Enclosure
Type

1
1
1
1
1

Branch Circuit Breakers (CH)
See Pages 2–14.

1
1

Renovation Loadcenter
Description

Catalog Number

1

Five-circuit terminal block kit
Ground bar kits (two maximum per panel)

RN5TB
(See Page 26)

1

Notes
 100A main breaker is rated 10 kAIC.
 Combination style covers may be used in surface or flush applications.

1
1

All main circuit breaker loadcenters are listed for use as service entrance equipment. Loadcenters
are factory-bonded for service entrance applications. Remove bonding strap for separate neutral
and ground bars for sub-feed applications.

1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

21

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Contents

Type CH Retrofit Interior

Description

1

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit Interior Kits
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1

2
19
21
23
24
25
29

1
Type CH Retrofit
Adjustable Interior

1

Type CH Retrofit Interior Collar
and Assembly with Trim

1
1
1

Type CH Retrofit Interior Kits

1

Product Description

Features and Benefits

Replacing existing
loadcenters and panelboards
can be a time consuming and
expensive job. CH retrofit kits
can be the solution to save
time and money. The kit
consists of a standard trim to
fit the interior, a picture frame
trim to fit the existing box,
and a field-adjustable interior
assembly that includes
neutral and ground bars.
These are especially
applicable when the existing
box is flush mounted in
drywall, plaster or block wall.
The existing box, and many
times existing wiring, can
remain.

Upgrading Existing Electrical
Infrastructure Is Simple
●
Replaces vintage brands
that have hard to find,
expensive replacement
breakers
●
Allows safety upgrade
to arc fault and ground
fault breakers
●
Maximizes number of
circuits available with
compact design
●
Meets 2008 NEC wire
bending requirements
●
Eco-friendly in asbestosfilled environments
●
Exclusive design

1
1
1
1
1
1
1
1
1

Save Time and Money
Throughout the Installation
●
Uses existing panel
box and wires
●
Eliminates expensive
drywall/paint repair
●
Saves 2–3 hours compared
to a complete panel
changeout—get off the
job faster
●
Eliminates precise
measurements with fieldadjustable kit

1
1
1
1
1
1

Standards and Certifications
Detailed Product Guide
All standard retrofit kits are
suitable for a range of
existing box sizes:
●

●

●

Box width ranging from
14.50 to 22.00 inches
(368.3 to 558.8 mm)
Box depth ranging from
4.25 inches (108.0 mm)
for CH to 6.00 inches
(152.4 mm)
Box height ranging from
21.00 to 45.00 inches
(533.4 to 1143.0 mm)

For box dimensions outside
of these ranges, contact
the Lincoln Flex Center at
800-330-6479. Be sure to
provide the existing incoming
line wire size.

1
1
1
22

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Interiors are UL recognized
under UL 67, Panelboard
standard.

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Product Selection

1

To select the retrofit kit:
1. From the existing box
size determine which
retrofit groups are
suitable (may be more
than one).

3. Select part number from
chart (if main breaker,
replace XXX with specific
amp rating).

2. Use type of interior,
number of phases, and
type of main to find the
selection chart.

4. Note that the overlap
of the existing wall is
the retro cover size
minus the existing
box size. If specific

measurements are
needed, communicate
that you need a custom
trim size.

1

5. Contact the Lincoln Flex
Center at 800-330-6479
for pricing, lead-times,
and order entry
instructions.

1

1
1
1
1

Retro Size Groups
Existing Box Height Determines Retro Size Group

1
1

Retro Size E

1

Retro Size D
Retro Size C

1

Retro Size B

1

Retro Size A
21"

29" 30"

34" 36" 37"

41"

45"

54"

1

Retrofit Stocking Kits (BR and CH Kits Available) 
Five recommended groups: existing box height determines retro group size.

Description

Retrofit
Kit Interior
Catalog Number

1
1

Depth

Existing Box Height
Determines Retro
Size Group—Inches (mm)

Collar
Catalog
Number

Cover
Catalog
Number

Existing Enclosure Parameters—Inches (mm)
Height

Width

BR-Aluminum Bus/CH-Copper Bus

1

BR 125A MLO 12/24 circuit retro kit

RAABR12L125

Included

Included

14.00–18.00
(355.6–457.2)

10.50–12.50
(266.7–317.5)

3.50–5.25
(88.9–133.35)

Retro size AA/size
14.00–21.00 (355.6–533.4)

1

BR 100A MCB 10/20 circuit retro kit

RAABR10B100

Included

Included

14.00–18.00
(355.6–457.2)

10.50–12.50
(266.7–317.5)

3.50–5.25
(88.9–133.35)

Retro size AA/size
14.00–21.00 (355.6–533.4)

1

BR 125A MLO 12/24 circuit retro kit

RAABR12L125A

Included

Included

14.00–21.00
(355.6–533.4)

10.50–15.50
(266.7–393.7)

3.50–5.25
(88.9–133.35)

Retro size AA/size
14.00–21.00 (355.6–533.4)

1

BR 100A MCB 10/20 circuit retro kit

RAABR10B100A

Included

Included

14.00–21.00
(355.6–533.4)

10.50–15.50
(266.7–393.7)

3.50–5.25
(88.9–133.35)

Retro size AA/size
14.00–21.00 (355.6–533.4)

1

CH interior 125A MCB 22 circuits

RACH22B125I

RACHFRAME

CH8CF

21.00–30.00
(533.4–762.0)

13.00–22.00
(330.2–558.8)

4.25–6.00
(108.0–152.4)

Retro size A/size
21.00–30.00 (533.4–762.0)

1

CH interior 125A MLO 24 circuits

RACH24L125I

RACHFRAME

CH8CF

21.00–30.00
(533.4–762.0)

13.00–22.00
(330.2–558.8)

4.25–6.00
(108.0–152.4)

Retro size A/size
21.00–30.00 (533.4–762.0)

CH interior 150A MCB 24 circuits

RBCH24B150I

RACHFRAME

CH8EF

29.00–36.00
(736.6–914.4)

13.00–22.00
(330.2–558.8)

4.25–6.00
(108.0–152.4)

Retro size B/size
29.00–36.00 (736.6–914.4)

CH interior 225A MLO 32 circuits

RBCH32L225I

RACHFRAME

CH8DF

29.00–36.00
(736.6–914.4)

13.00–22.00
(330.2–558.8)

4.25–6.00
(108.0–152.4)

Retro size B/size
29.00–36.00 (736.6–914.4)

CH interior 200A MCB 32 circuits

RCCH32B200I

RCCHFRAME

CH8JF

34.00–41.00
(863.3–1041.4)

13.00–22.00
(330.2–558.8)

4.25–6.00
(108.0–152.4)

Retro size C/size
34.00– 41.00 (863.3–1041.4)

CH interior 225A MLO 42 circuits

RCCH42L225I

RCCHFRAME

CH8GF

34.00–41.00
(863.3–1041.4)

13.00–22.00
(330.2–558.8)

4.25–6.00
(108.0–152.4)

Retro size C/size
34.00– 41.00 (863.3–1041.4)

CH interior 200A MCB 42 circuits

RDCH42B200I

RDCHFRAME

CH8KF

37.00–45.00
(939.8–1143.0)

13.00–22.00
(330.2–558.8)

4.25–6.00
(108.0–152.4)

Retro size D/size
37.00–45.00 (939.8–1143.0)

CH interior 225A MLO 42 circuits

RDCH42L225I

RDCHFRAME

CH8KF

37.00–45.00
(939.8–1143.0)

13.00–22.00
(330.0–558.8)

4.25–6.00
(108.0–152.4)

Retro size D/size
37.00–45.00 (939.8–1143.0)

1
1

Notes
 Other options are available.
 CH retrofit interiors and collar cartons are color coded to ensure accuracy of kit.

1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

23

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Contents

Circuit Analyzer

Description

1

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Analyzer
Technical Data and Specifications . . . . . . . . . . . . . . . . . .
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1

2
19
21
22
25
25
29

1
1
1
1
1

Circuit Analyzer

1

Product Description

Application Description

Features, Benefits and Functions

Eaton’s Circuit Analyzer
provides accurate testing
of AFCI and GFCI devices
while also testing for faulty
wiring conditions.

The Circuit Analyzer serves
as a handy troubleshooting
tool for contractors and
electrical inspectors. It
provides accurate testing of
AFCI and GFCI devices while
also testing for faulty wiring
conditions.

●

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

There are other testing devices
on the market, but this will be
the only one available from an
AFCI manufacturer. Eaton
has more than 100 years of
electrical control and power
distribution experience, and a
thorough understanding of
what arc faults are all about.
This experience with AFCI
breakers led to developing
a feature of the analyzer that
will save contractors time
and aggravation. It allows
contractors to verify whether
they have a grounded neutral
simply by depressing the
red Neutral Isolation test
button. In this way, they will
be able to determine whether
they have a grounded neutral
or have other neutrals
connected before they leave
the job site. Additionally,
the Circuit Analyzer has a
button that tests AFCI and
two that test GFCI devices
(both 40 mA and 8 mA).

●

●

●

All-in-one tester for ground
fault, arc fault and faulty
wiring conditions
Neutral isolation test
button is a feature that
allows the contractor to
determine whether they
have a grounded neutral
or have other neutrals
connected before leaving
the job
Additional Test button for
AFCI and two that test
GFCI devices (40 mA
and 8 mA)
Only product available from
an AFCI manufacturer

1
1
1
24

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

●

Three standard
accessories enhance
the usefulness of the
Circuit Analyzer:
●
An alligator clip
attachment to test
hardwired circuits, such
as smoke detectors,
that lack a receptacle.
The clip simply is
attached to the smoke
alarm’s terminals
●
An adapter (three-prong
to two-prong) for testing
in older homes that lack
three-prong receptacles
●
Light socket adapter for
AFCI testing when no
receptacle is available.
Examples are ceiling
fans that contain
sockets and recessed
lighting
●
Additionally, the Circuit
Analyzer comes with a
black carrying case

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Technical Data and Specifications

1

How it Works
1. Plug the tester (or one
of the accessories) into
the receptacle, light
fixture or hardwired
terminals to be tested.

1

3. If the circuit is wired
correctly, then proceed
to test for neutral
isolation, arc fault or
ground fault conditions,
depending on the
breaker or receptacle
type that is on the circuit.

2. Check the wiring LEDs
on the Circuit Analyzer to
determine if the circuit is
wired correctly.

1
1
1
1

4. To perform these tests,
press the corresponding
button on the Circuit
Analyzer and review
the results.

1
1

Options and Accessories

1
CHSF2125

Description

Ordering
Quantity 

Catalog
Number

Sub-feed lug blocks—two-pole, 125A, 3/4-inch (19.1 mm) spaces needed

1

CHSF2125

Sub-feed lug blocks—three-pole, 125A, 3/4-inch (19.1 mm) spaces needed

1

CHSF3125

Neutral/ground lug—add-on neutral or ground lug

1

NL20

1

NL30

1

NL300

25

CHFP

CSR main circuit breaker filler plate (with hardware)

1

CSRFP

Door lock—12–42 circuits, and 100–225A

1

TDL

Sandlewood spray paint

1

SPCSW

ANSI-61 light gray touchup paint for outdoor loadcenters

1

SPC61

Isolated neutral assembly (computer circuits)

1

BINA

Circuit directory—adhesive backed

10

TCD

Cover screws

25

LCCS

Cover replacement latch 14-5/16 inch (363.55 mm) wide loadcenters only

1

CHRLS

Circuit marking strip (next to breakers)

10

CHMS

Circuit identification label (preprinted breaker labels next to breakers)

25

CHBL

Series rated caution label

25

SRL

Branch circuit numbering strip

20

CHNS

Bonding strap with screw

1

BSSUSE

CHSF3125
Filler plates—3/4-inch (19.1 mm) space circuit breaker space

CHFP

TDL

1

Field Installation and Parts

1
1
1
1
1
1
1
1
1
1
1
1

BINA

1
1
1

CHRLS

1
1
1

Note
 Must be purchased in multiples of ordering quantities indicated.

1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

25

1.1
1

DS100H1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Field Installation Rainproof Conduit Hubs
Conduit Size

1
1

Description

Inches (mm)

Ordering
Quantity 

Catalog
Number

Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures,
and the following 150 and 200A panels: CH8B150RF, CH8B200RF

0.75 (19.1)

1

DS075H1

1.00 (25.4)

1

DS100H1

1.25 (31.8)

1

DS125H1

1.50 (38.1)

1

DS150H1

2.00 (50.8)

1

DS200H1

2.00 (50.8)

1

DS200H2

2.50 (63.5)

1

DS250H2

3.00 (76.2)

1

DS300H2

Adapter kit—allows Installing a Group 1 hub on devices arranged for Group 2 hubs

—

1

DS900AP

Group 1—small blank hub closure plate

—

1

DS900CP1

Group 2 — large blank hub closure plate

—

1

DS900CP2

1
1

Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosure
except for the following 150 and 200A panels: CH8B150RF, CH8B200RF

1
1
1
1
1

GBK14

Ground Bar Kits
Length

1

Description (See Legend)





1

















1







1
1
1
1

1

1

Catalog
Number

2.54 (64.5)

1

GBK5 

3.59 (91.2)

1

GBK520 

4.29 (109.0)

1

GBK10 

5.34 (135.6)

1

GBK1020 

4.61 (117.1)

1

GBK13 

5.69 (144.5)

1

GBK14 

6.74 (171.2)

1

GBK1420 

8.14 (206.8)

1

GBK21 

9.19 (233.4)

1

GBK2120 

7.94 (201.7)

1

CH9GP21 

 

1

1

Ordering
Quantity 

Ground Bar Legend
 = (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
 = (1) #6–2/0 Cu/Al
= (1) 1/0–14 or (3) #10–12 Cu/Al
= (1) #14–1/0 Cu/Al or (3) #14–#10 Cu/Al
 = Mounting hole

1

1

Inches (mm)

Grounded “B” Phase Adapters

Neutral Bar Accessories

Maximum
Amperes

Three-Phase Loadcenter
Types of Panels

Kit Catalog
Number 

Description

Catalog
Number 

125

12–32 circuit main lug

CHGRD1

Split neutral kit for 22 circuit 125A maximum

CHSN125C

225

Main lug and CHH main breaker panels

CHGRD2

Split neutral kit for 32 circuit 200A maximum

CHSN225J

CC main CB panels

CHGRD3

Split neutral kit for 42 circuit 200A maximum

CHSN225K

Replacement neutral for all C type boxes

CHN125C

Replacement neutral for all D type boxes

CHN125D

Replacement neutral for all L type boxes

CHN225L

Isolated Neutral Assembly (computer circuits)

BINA

1
1
1

Notes
 Must be purchased in multiples of ordering quantities indicated.
 Distance between mounting holes is 1-3/4 inches (44.5 mm).
 For single- and three-phase 400A loadcenters.
 Distance between mounting holes is 2-13/32 inches.
 Cannot be used in Safety Breaker Panels. Classic Plus Panels only.

1
1
1
1
26

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Mechanical Interlock Covers
Covers mechanically interlock
two breakers. Type A covers
interlock two CH breakers
mounted across from one
another. Type B covers
interlock a main Type CSR
breaker with a Type CH.

1
1
1
1
1

Mechanical Interlocks

CH8BRM Type A

CH8EFM Type B

1

Type

Fits Loadcenter
Catalog Numbers

Mechanical Interlock Panel Cover Catalog Number
Flush
Surface

A

CH12L125B, CH16L125B, CH12L3125B, CH14B100B

CH8BFM

CH8BSM

CH20L125C, CH24L125C, CH18L3125C, CH24L3125C, CH22B100C, CH22N100C

CH8CFM

CH8CSM

CH24L150D, CH32L150D, CH24L3225D, CH30L3150D

CH8DFM

CH8DSM

CH42L225G, CH42L3225G

CH8GFM

CH8GSM

Inner cover of Box B raintight

—

CH8BRM

Inner cover of Box C raintight

—

CH8CRM

1

CH24B150E, CH24B200E

CH8EFM

CH8ESM

1

CH32B150J, CH32B200J, CH3242B200J, CH32N200J, CH32B225J

CH8JFM

CH8JSM

CH42B200K, CH42N200K, CH42B225K

CH8KFM

CH8KSM

CHPC32B150L, CHPC32B200L, CHPC32N200L

CHPC8B32LFM

—

CHPC42B150L, CHPC42B200L, CHPC42N200L

CHPC8B42LFM

—

CH8B150RF, CH8B200RF, CH8N200RF, CH24B150R, CH24B200R

CH3RDF7M

—

CH32B150R, CH32B200R, CH32N200R, CH32B225R

CH3RDF9M

—

CH42B200R, CH42N200R, CH42B225R

CH3RDF10M

—

B

1
1
1

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

27

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Decorator Cover Accessory
●
For easy use with CH loadcenters mounted in living space
●
Easily wallpapered or painted to match any decor
●
Loadcenter accessory—exclusively from Eaton

1
1

CH Loadcenter Goof Collars
Don’t let an ugly drywall problem ruin a beautiful
electrical installation.
Eaton’s Goof Collar is designed to cover gaps between the
finished drywall and loadcenter enclosure. This is often
necessary when upgrading the electrical service and the drywall
surrounding the panel is damaged. The collar allows 2 inches of
overhang beyond the standard flush trim.

1

Currently available in three sizes for the CH style loadcenters.

1

Goof Collars are also available for the BR style loadcenters
upon request. Please contact the Lincoln Flex Center at
1-800-330-6479 for questions and product opportunities.

1
1
1
Now you see it …

1
1

SCOTT
HAS
PHOTO

… Now you don’t.

Decorator Cover Accessory 
Catalog Number
Corresponding Cover

Existing CH Loadcenter Cover

CH8BF

CH8KDNB

CH8CF

CH8KDNC

CH8DF/EF

CH8KDND

CH8GF/JF

CH8KDNJ

Goof Collars

CH8KF

CH8KDNK

Inches (mm)
Height

Width

Catalog Number
Loadcenter Cover

Goof Collar

1

26.00 (660.4)

19.00 (482.6)

CH8CF

CH8CFC1926

39.00 (990.6)

19.00 (482.6)

CH8JF

CH8JFC1939

1

42.00 (1066.8)

19.00 (482.6)

CH8KF

CH8KFC1942

1

Note
 For interlock covers for loadcenters not listed in chart, please contact the Flex Center
at 1-800-330-6479.

1
1
1
1

Before

After

1
1
1
1
1
1
1
1
1
1
1
1
28

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Contents

Plug-On Circuit Breakers

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Analyzer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories. . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . .
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2
19
21
22
24
25
29
31
37
39
39
39
41

1
1
1
1
1
1
1
1
1
1
1

Circuit Breakers

1

Product Description
Quick-make, quick-break
switch mechanism combined
with inverse time element
tripping operation and tripfree handle design. Type CH
circuit breakers trip to the
OFF position, eliminating
nuisance callbacks. The
thermal-magnetic trip curve
avoids nuisance tripping on
mild overloads while reacting
almost instantaneously
to severe short-circuit
conditions. Multipole breakers
have internal common trip
connection to operate all
poles simultaneously. Handles
are marked with ON-OFF
indication and ampere rating
of the breaker.
Special Application Plug-On
Circuit Breakers—Type CH
10 kAIC 120 Vac and 120/240 Vac
Branch Feeder Type Arc
Fault Circuit Breakers
A branch feeder type arc fault
circuit interrupter is a device
intended to mitigate high
current arcing faults in the
complete circuit, including
connected cords. High
current arcing faults can
occur from line to neutral or
line to ground. These arcing
faults are in parallel with the
load and produce the most
energy of all arcing faults.

The branch feeder type AFCI
is required in the 1999 and
2002 National Electrical Code.
The Combination Type AFCI
is required in the 2005 and
2008 National Electrical Code.
Combination Type Arc
Fault Circuit Breakers
A combination type arc fault
circuit interrupter is a device
that includes all of the
protection offered by the
branch feeder AFCI (mitigation
of high current arcing faults in
the complete circuit, including
connected cords). In addition
it provides direct detection of
persistent low current arcing
faults down to 5 amps with
associated mitigation of
fire hazards in the cords
connected to the outlets. High
current arcing faults can occur
from line to neutral or line to
ground. These arcing faults
are in parallel with the load
and produce the most energy
of all arcing faults. The current
level of low current arcing
faults is limited by the load.

Ground Fault Circuit
Breakers—Ground Fault
Application Notes
Single-pole Type CHGFIs are
designed for use in two-wire,
120 Vac circuits. The diagram
on Page 39 shows a typical
wiring configuration.
Two-pole Type CHGFIs are
designed for use in threewire, 120/240 Vac circuits,
120 Vac multiwire circuits
employing common, neutral
and two-wire, 240 Vac
circuits obtained from a
120/240 Vac source.

The figures are shown with
a 120/240 Vac, single-phase,
three-wire power source,
but are also applicable to a
120/208 Vac, three-phase,
four-wire power supply.
For all figures, the electrical
operation of the Type CHGFI
is not affected by the
equipment ground.

1
1
1
1
1
1
1
1

Diagrams on Page 39 illustrate
typical wiring configurations
for 120/240 Vac multiwire
circuits.

1
1

The diagram on Page 39
depicts a 240 Vac, two-wire
circuit. Note the “panel
neutral” conductor connects
to the neutral bar, even
though the neutral is not
included in the load circuit.
This connection is necessary
to supply a 120 Vac power
source to the ground fault
sensing circuit.

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

29

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Features
Over-Center
Toggle Spring

1

Magnetic
Armature

1
1

Latch
Lever

Current
Bi-Metal

Latch
Spring

Calibration
Screw
(under
UL label)

1
1
1

Load
Terminal

1
1
1

Line
Contact
Clip
Contact
Clip Spring

Contact
Magnetic
Pole Piece

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Plug-On Type CH Breaker

1
1
30

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Product Selection

1

10 kAIC, 120 Vac, 120/240 Vac and 240 Vac

Plug-On Circuit
Breakers

1
1

Type CH Breakers, 3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAIC

Ampere
Rating
10
15

Wire Size
Range Cu/Al
60ºC or 75°C
(1) #14–8 
(2) #14–10 
(1) #14–6 

20

Catalog Number
Single-Pole 120/240 Vac
Requires One
3/4-Inch (19.1 mm) Space
10 per Shelf Carton

Two-Pole 120/240 Vac
Common Trip Requires Two
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton

1

Three-Pole 240 Vac
Common Trip Requires Three
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton

1
1

CH110

CH210

CH310

CH115 

CH215 

CH315 

CH120 

CH220 

CH320 



CH325 

CH230 

CH330 



25

CH125

30

CH130 


CH225

CHF215



CHF315

1
1
1



15

CHF115

20

CHF120 

CHF220 

CHF320 

25

CHF125 

CHF225 

CHF325 

30

CHF130 

CHF230 

CHF330 

1
1

35

#14–2 
#14–6 

CH135 

CH235 

CH335 

1

40

#10–1/0 
#14–2 
#3/0 

CH140 

CH240 

CH340 

1





CH345 

CH250 

CH350 

45

CH145

CH245

50

CH150 

70

CH170

CH270

CH370

80

—

CH280

CH3080

90

—

CH290

CH3090

100

—

CH2100

CH3100

110

—

CH2110

—

125

—

CH2125

—

150

—

CH2150 	

—

1
1
1
1
1
1

Notes
 For single- and two-pole breakers.
 Solid and stranded wire can be used together.
 For three-pole breakers.
 Single-pole 60–70A, two-pole 80–125A, three-pole 40–100A.
 Single-pole 40–50A, two-pole 40–70A.
 Two-pole 150A.
 Switching duty rated.
 HACR rated.
	 CH2150 requires four-pole spaces and is not suitable for use on three-phase panels, not CSA certified.
 With trip indication.

1
1
1
1

For factory-installed options, refer to Page 38.

1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

31

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Plug-On Branch Feeder Type Arc Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 Vac
Type CH Single-Pole
AFCI Circuit Breaker

1
1

Type CH 3/4-Inch (19.1 mm) Wide FIRE-GUARD ® AFCI Circuit Breakers
Poles

Ampere Rating

Configuration

Catalog Number

Single-pole
10 kAIC

15

AFCI

CH115AF 

20

AFCI

CH120AF 

15

AFCI common trip

CH215AF

20

AFCI common trip

CH220AF

Two-Pole
10 kAIC 

1
1
1
1
1

Plug-On Combination Type Arc Fault Circuit Breakers, Type CH 10 kAIC,120 Vac and 120/240 Vac

1

Type CH Single-Pole
PON Combo AFCI
Circuit Breaker

1

Type CH 3/4-Inch (19.1 mm) Wide FIRE-GUARD Combination Type AFCI Circuit Breakers
Poles

Ampere Rating

Configuration

Single-pole
10 kAIC

15

AFCI

1

AFCI plug-on neutral, no pigtail
20

1

Two-pole
10 kAIC

1

Catalog Number
CH115CAF 


CH115CAFPN
CH120CAF 

AFCI

15

20

1

AFCI plug-on neutral, no pigtail 

CH120CAFPN

AFCI

CH215CAF

AFCI plug-on neutral, no pigtail 

CH215CAFPN

AFCI

CH220CAF

AFCI plug-on neutral, no pigtail 

CH220CAFPN

1
1
1

Plug-On Ground Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 Vac
Type CH Single-Pole

Type CH Ground Fault Circuit Breakers (5 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or
120/240 Vac,10 kAIC

1
1

Catalog Number—1 per Shelf Carton
Single-Pole 120 Vac Requires
One 3/4-Inch (19.1 mm) Space

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces

Ampere Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

#14–6 

CH115GF

CH215GF

1

20

#14–6 

CH120GF

CH220GF

25

#14–6 

CH125GF

CH225GF

1

30

#14–6 

CH130GF

CH230GF

35

#14–6 

—

CH235GF

40

#14–6 

—

CH240GF

45

#14–6 

—

CH245GF

50

#14–6 

—

CH250GF

60



—

CH260GF

1

1
1
1

#14–6

Notes
 Clamshell packaging available with CS modification code on the end of catalog number.
 Common trip refers to two-pole 240V load application sourced by 120/240 Vac (see diagram on Page 39).
 Independent trip refers to two-pole multi-wire, home run or shared neutral circuits (see diagrams on Page 39).
 Requires plug-on neutral loadcenter.
 60A breaker listed for 75°C Cu wire only.

1
1
1
1
32

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1
1

Type CH Two-Pole

Type CH Ground Fault Equipment Protectors (30 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or
120/240 Vac, 10 kAIC
Catalog Number—1 per Shelf Carton
Single-Pole 120 Vac Requires
One 3/4-Inch (19.1 mm) Space

1
1

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces

1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

#14–6 

CH115EPD

CH215EPD

20

#14–6



CH120EPD

CH220EPD

25

#14–6 

CH125EPD

—

30

#14–6 

CH130EPD

CH230EPD

40

#14–6 

—

CH240EPD

50

#14–6 

—

CH250EPD

60

#14–6 

—

CH260EPD

1
1
1
1
1
1

Type CH Switching Neutral Breakers—10 kAIC, 120 Vac and 120/240 Vac
Used to open the neutral along power line(s) for applications of gas pumps.
CH220SW

1

3/4-Inch (19.1 mm) per Pole 120/240 or 240 Vac, 10 kAIC
Catalog Number—1 per Shelf Carton
Two-Pole 120 Vac
Common Trip Requires
Two 3/4-Inch (19.1 mm) Spaces

1
1

Three-Pole 120/240 Vac
Common Trip Requires
Three 3/4-Inch (19.1 mm) Spaces

1

Phase
Phase
Neutral Out
Neutral In

(Hot leg)
Neutral Out
Neutral In

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

#14–8

CH215SW 

CH315SW 

20

#14–8

CH220SW 

CH320SW 

30

#14–8

CH230SW 

CH330SW 

40

#14–8

CH240SW 

CH340SW 

50

#14–8

CH250SW 

CH350SW 

1
1
1
1
1

Type CH-HID Circuit Breakers—10 kAIC, 120 Vac, 120/240 and 240 Vac
Suitable for use in circuits for fluorescent and high intensity discharge lighting. Also suitable for HACR applications.

1
1

3/4-Inch (19.1 mm) per Pole 120 Vac, 120/240 and 240 Vac, 10 kAIC
Single-Pole 120/240 Vac
Requires One
3/4-Inch (19.1 mm) Space

Two-Pole 240 Vac
Common Trip Requires
Two 3/4-Inch (19.1 mm) Spaces

10 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

Three-Pole 240 Vac
Common Trip Requires
Three 3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton
Catalog Number

1
1
1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°

15

#14–8

CH115HID

CH215HID 

CH315HID

20

#14–8

CH120HID

CH220HID

CH320HID

30

#14–8

CH130HID

CH230HID

CH330HID

1
1

Notes
 60A breaker listed for 75°C Cu wire only.
 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space.
 Switching duty rated.
 CH215HID is rated for 120/240V.

1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

33

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Non-CTL Plug-On Replacement Circuit Breakers, Type CHNT 10 kAIC, 120/240 Vac
For use as replacement in loadcenters built prior to 1968 and within the current style 2–8 circuit
loadcenters as indicated in the loadcenter section.
3/4-Inch (19.1 mm) per Pole 120 Vac, Non-CTL 10 kAIC

1

Single-Pole Requires
One 3/4-Inch (19.1 mm) Space
10 per Shelf Carton
Catalog Number

1
1

Ampere
Rating

1
1

Wire Size Range
Cu/Al 60ºC or 75°C

120/240 Vac
120/240 Vac

15–15

#14–8

CHNT1515 

15–20

#14–8

CHNT1520 

20–20

#14–8

CHNT2020 

1
1
1
1

CTL Plug-On Circuit Breakers, Type CHT Twin 10 kAIC, 120/240 Vac
All circuit breakers have rejection feature. Use only with loadcenters marked for use with CHT breakers.
Type CH and CHT
Circuit Breakers
Mounted in Twin
Breaker Panel

1
1
1
1

Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAIC
Single-Pole Requires
One 3/4-Inch (19.1 mm) Space
10 per Shelf Carton
Catalog Number
Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15–15

#14–8

CHT1515 

15–20

#14–8

CHT1520 

20–20

#14–8

CHT2020 

120/240 Vac
120/240 Vac

Notes
 Switching duty rated.
 HACR rated.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
34

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Type CHP Commercial Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 Vac
Note: CHP breakers feature on-off and trip positions for commercial applications.

1

3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAIC

1

Single-Pole 120/240 Vac
Requires One 3/4-Inch
(19.1 mm) Space

Two-Pole 120/240 Vac
Common Trip
Requires Two 3/4-Inch
(19.1 mm) Spaces

10 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

Three-Pole 240 Vac
Common Trip
Requires Three 3/4-Inch
(19.1 mm) Spaces
5 per Shelf Carton
Catalog Number

CHP110

CHP210

CHP310

CHP115 

CHP215 

CHP315 

20

CHP120 

CHP220 

CHP320 

25

CHP125 

CHP225 

CHP325 

30

CHP130 

CHP230 

CHP330 

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

10

(1) #14–8 
(2) #14–10 
(1) #14–6 

15

#14–2 
#14–6 

CHP135 

CHP235 

CHP335 

40

#10–1/0 
#14–2 

CHP140 

CHP240 

CHP340 







CHP145

CHP245

CHP345

1
1
1

35

45

1

50

CHP150 

CHP250 

CHP350 

60

CHP160 

CHP260 

CHP360 

70

CHP170

CHP270

CHP370

80

—

CHP280

—

90

—

CHP290

—

100

—

CHP2100

CHP3100

110

—

CHP2110

—

125

—

CHP2125

—

1
1
1
1
1
1
1
1
1
1
1

Type CHP-GFCI Circuit Breakers—10 kAIC, 120 Vac and 120/240 Vac
Note: CHP breakers offer on-off and trip positions for commercial applications.

1

5 Milliampere—3/4-Inch (19.1 mm) per Pole
120V and 120/240 Vac, 10 kAIC

1

Single-Pole 120 Vac Requires
One 3/4-Inch (19.1 mm) Space

1

1 per Individual Carton
Catalog Number
Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

#14–6

CHP115GF

20

#14–6

CHP120GF

30

#14–6

CHP130GF

1
1
1
1

Notes
 For single- and two-pole breakers.
 Solid and stranded wire can be used together.
 For three-pole breakers.
 Single-pole 60–70A, two-pole 80–125A, three-pole 40–100A.
 Single-pole 40–50A, two-pole 40–70A.
 Switching duty rated.
 HACR rated.

1
1
1
1

CHP breakers offer on-off and trip positions for commercial applications.

1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

35

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Type CHP Neutral Switching Breakers—10 kAIC, 120 Vac and 120/240 Vac
Used to open the neutral along power line(s) for applications of gas pumps.

1
1

3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC
Two-Pole 120 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces
1 per Shelf Carton
Catalog Number

1
1
1
1
1
1

Three-Pole 120/240 Vac Common Trip
Requires Three 3/4-Inch (19.1 mm) Spaces
1 per Shelf Carton
Catalog Number
Phase
Phase
Neutral Out
Neutral In

(Hot leg)
Neutral Out
Neutral In

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

#14–8

CHP215SW 

CHP315SW 

20

#14–8

CHP220SW 

CHP320SW 

Type CH-M50 High Ambient Breaker
3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC

1

Single-Pole 120/240 Vac
Requires One 3/4-Inch (19.1 mm) Space
10 per Shelf Carton
Catalog Number

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton
Catalog Number

CH115M50

CH215M50

CH120M50

CH220M50

1

25

CH125M50

CH225M50

30

CH130M50

CH230M50

1

35

CH135M50

CH235M50

40

CH140M50

CH240M50

45

CH145M50

CH245M50

1

50

CH150M50

CH250M50

60

—

CH260M50

1

70

—

CH270M50

1
1
1

1

1
1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

20

Type CH-HM and CHP-HM High Magnetic Breakers
3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC

1
1
1
1
1
1
1

Single-Pole 120/240 Vac
Requires One 3/4-Inch (19.1 mm) Space
10 per Shelf Carton
Catalog Number

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton
Catalog Number

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

CH115HM

CH215HM

CH120HM

CH220HM

(1) #14–8
(2) #14–10

CHP115HM

CHP215HM

CHP120HM

CHP220HM

20
15
20

Note
 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space, obtain pricing from Page 38.

1
1
1
36

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Options and Accessories

CHHT

1
Ordering
Quantity 

Catalog
Number

25

CHHT

Padlockable device for locking the handle of single-, two- or three-pole Type CH circuit breakers (escutcheon mounted) 

1

CHPL

Padlockable device for locking the handle of a single-, two- or three-pole Type CHGFI circuit breaker (escutcheon mounted) 

1

CHPLGF

Padlockable device for locking the handle of main circuit breaker Types CC and CCH into the ON or OFF position.(screw mounted) 

1

CCPL

Padlockable device for locking the handle of main breaker Types BW and CSR into the ON or OFF position (escutcheon mounted) 

1

MCBPL

10

CHLO

Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers. For 6–24 circuit 125A single- and three-phase,
12–42 circuit single-phase 225A and 24–42 circuit three-phase 225A MLO Type CH loadcenters

1

CH125RB

Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers for 2–4 circuit MLO CH loadcenters.

1

CH125RB24

1

CH9MB270

Types CC and CCH main breaker lug kit (2) 300 kcmil

1

CCL300

Type CSR main breaker lug kit (2) 300 kcmil

1

MCBL300

10

CHML

10

CHPLOFF

10

CHPLOFFA

10

CHL1P

10

CHL2P

Description
Handle Ties
CHPL

CHPLGF

1

Field Installation Kits and Parts

1



Handle tie bar for physically joining the handles of two adjacent single-pole Type CH circuit breakers (molded plastic handle cover)

1
1

Handle Lockoffs 

1
1

Handle Lockdogs 
Device used to secure handle in ON or OFF position for single-pole Type CH circuit breakers (handle mounted) 

1
1

Hold-Down Kits 	
MCBPL

1
1

Mounting Bases
CHLO

Mounting base for two-pole Type CH circuit breaker—70A maximum

1

Main Breaker Lug Kits

CH125RB

1
1

Mechanical Interlock
Type CH for two-, three- and four-pole breakers

1
1
1
1

CH9MB270

1
1
1
1

CHML

1
1
1

Notes
 Must be purchased in multiples of ordering quantities indicated.
 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker.
 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position.
 Requires one additional pole space.
 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront.
 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw.
 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle lockdogs are not padlockable devices.
 Handle mounted: device mounted above or below handle using spring pressure.
	 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384-16(g).

1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

37

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Shunt Trip Options
Description
Type

Volts

Catalog Number
Suffix Adder 

CSR

12 DC

SR12

CSR

24 DC

SR24

CSR

120 AC

SR01

CH

120 AC

ST 

1

CC

12 DC

SR12

CC

24 DC

SR24

1

CC

120 AC

SR01

CC

208 AC

SR08

CC

240 AC

SR02

1
1
1

1
1

Handle Position Changeability Chart

1
1

Handle Lockoff and
Lockdog Types

To Change Handle Position from
ON to OFF or OFF to ON You Must...
Remove
Remove
Remove Loadcenter
Padlock
Device
Deadfront

1

Lockoff escutcheon mounted

Remove

—

—

Lockoff screw mounted

Remove

—

—

Lockdog handle mounted

N/A

Remove

—

1
1
1

Notes
 Add suffix indicated to end of breaker catalog number.
 Requires one additional pole space.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
38

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Technical Data and Specifications

1

Ratings
Single- and two-pole CH breakers rated 15 and 20A have
low instantaneous magnetic trip levels. The 15 and 20A
breakers with “HM” suffix have high magnetic trip settings
recommended for circuits with inherently high inrush currents.
All Type CH breakers are marked for heating, air conditioning
and refrigeration (HACR) equipment application. Single-pole
15–20A breakers are also suitable for switching duty (SWD).
Shunt trip coils operate on 120 Vac and require one additional
pole space per breaker.

1
1
1
1
1

Wiring Diagrams
Typical Single-Pole

Two-Pole 240V Load Application Sourced by 120/240 Vac

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
1
1

Line B

Line B

1
1

Two-Pole

Single-Pole
120V
Duplex
Receptacle

Neutral
Neutral

240V
Duplex
Receptacle

Line A
Neutral

1
1

Equipment Ground

1
Single-Pole 120V Load Application Sourced by 120/240 Vac

Two-Pole Shared Neutral with Duplex Receptacle Application

1

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
1

Line B

Line B
Line A

1
Two-Pole

Single-Pole
Neutral

120V
Duplex
Receptacle

Neutral

Neutral
Neutral

Equipment Ground

Two-Pole Shared Neutral with Multi-Duplex
Receptacle Application

1

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1

Equipment Ground

1
1

Single-Pole 120V Duplex
Receptacle Application

1

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
1

Line B
Line B

1

Single-Pole

Two-Pole

Neutral
Neutral

Neutral

Two 120V
Duplex
Receptacles

Neutral

120V
Duplex
Receptacle

1
1

Equipment Ground

1
Equipment Ground

Line A

1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

39

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Two-Pole 120V Multi-Duplex Receptacle Application
120/240 Vac
Source
N A B

1

Line B

1
Two-Pole

1

Neutral
Neutral

1
1

Two 120V
Duplex
Receptacles

Line A

1
1
1

Two-Pole 120V Duplex Receptacle Application
120/240 Vac
Source
N A B
Line B

1

Line A

1

Two-Pole
Neutral

1
Neutral

1

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1
1
1
1

Two-Pole 240V Duplex Receptacle Application
120/240 Vac
Source
N A B
Line B

1
1

Two-Pole
Line A

1

Neutral

240V
Duplex
Receptacle

1
1
1
1
1
1
1
1
1
40

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Dimensions

1

Approximate Dimensions in Inches (mm)

1

Residential Loadcenter Knockout
Residential NEMA Type 1 Indoor and NEMA Type 3R
Outdoor Enclosures.

Residential/Commercial/Unit Enclosure—Box Sizes
Note: Box sizes do not include covers/fronts.

1

Residential Loadcenters
Box Size

Height

Width

Depth

NEMA Type 1 Indoor

1

Knockouts for Box Sizes 5, 6, 7, 5R, 6R, 7R
Code

Diameter

5

9.50 (241.3)

4.50 (114.3)

3.13 (79.4)

A

0.50 (12.7)

—

—

—

6

11.38 (288.9)

6.88 (174.6)

3.39 (86.1)

B

0.50 (12.7)

0.75 (19.1)

—

—

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

7

13.00 (330.2)

11.00 (279.4)

3.69 (93.7)

C

B

16.75 (425.5)

14.31 (363.5)

3.88 (98.4)

D

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

—

C

21.00 (533.4)

14.31 (363.5)

3.88 (98.4)

E

D

29.13 (739.8)

14.31 (363.5)

3.88 (98.4)

F

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

E

29.13 (739.8)

14.31 (363.5)

3.88 (98.4)

G

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

G

34.13 (866.8)

14.31 (363.5)

3.88 (98.4)

H

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

I

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

J

34.13 (866.8)

14.31 (363.5)

3.88 (98.4)

K

37.00 (939.8)

14.31 (363.5)

3.88 (98.4)

L

39.00 (990.6)

14.31 (363.5)

3.88 (98.4)

1
1
1
1
1
1
1

Knockout Positions

NEMA Type 3R Outdoor
5R

9.50 (241.3)

4.50 (114.3)

3.13 (79.4)

6R

11.75 (298.5)

6.50 (165.1)

4.50 (114.3)

7R

13.00 (330.2)

11.00 (279.4)

3.69 (93.7)

B

16.75 (425.5)

14.31 (363.5)

5.19 (131.8)

C

21.00 (533.4)

14.31 (363.5)

5.19 (131.8)

D

29.13 (739.8)

14.31 (363.5)

5.19 (131.8)

E

29.13 (739.8)

14.31 (363.5)

5.19 (131.8)

G

34.13 (866.8)

14.31 (363.5)

5.19 (131.8)

J

34.13 (866.8)

14.31 (363.5)

5.19 (131.8)

K

37.00 (939.8)

14.31 (363.5)

5.19 (131.8)

L

39.00 (990.6)

14.31 (363.5)

5.19 (131.8)

1
F

1

A

D

D

F

B

F

Width

Depth
A

NEMA Type 1 Indoor
P

21.00 (533.4)

62.63 (1590.7)

D

1

A

1

Box 5R

1

B

H

1

D

A

F

A

Hub

A

C

F

1
F
B

F

C

1
A

D

F

F

1

D

B

6.00 (152.4)
A

PM

D

A

B

F

54.38 (1381.1)

D

Box 5

Commercial Loadcenters
Height

1

Hub

A

A

D

A

Box Size

A

21.00 (533.4)

6.00 (152.4)

B

A

H

B

Box 6

B

H

B

1

Box 6R

1

Types ECB and ECC Unit Enclosures
Height

Width

Depth

B C
A A A

NEMA Type 1 Indoor
23.25 (590.6)

8.88 (225.4)

4.50 (114.3)

B B

1

Hub

A A A

1

B B

G

B

NEMA Type 3R Outdoor
23.69 (601.7)

G

A

G

A

9.31 (236.5)

5.44 (138.1)

C
G

B

C
C
A A A

B C

F
G

A A A
A

Box 7

B B

1

C
G

G

F

C
A A A

B C

G

G

1

A A A
A

B B

1

Box 7R

1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

41

1.1
1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Approximate Dimensions in Inches (mm)
Residential and Commercial Loadcenter Knockout
Residential NEMA Type 1 indoor and NEMA Type 3R outdoor enclosures.
Knockouts for Box Sizes 8, 8R, P, PM, B, C, D, E, G, J, K, L
and Outdoor Boxes 12–42 Circuits

Type ECB and ECC Unit Enclosure Knockout
Code

Diameter in Inches

1

Code

1

a

0.75 (19.1)

—

—

—

—

A

0.50 (12.7)

—

—

—

—

b

0.50 (12.7)

0.75 (19.1)

—

—

—

B

1.25 (31.8)

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

c

0.50 (12.7)

—

—

—

—

NEMA Type 3R Outdoor

d

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

A

0.50 (12.7)

—

—

—

—

e

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

—

B

1.25 (31.8)

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

f

0.75 (19.1)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

g

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

—

1

h

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

—

—

i

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

1

j

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

—

1
1
1

1
1

Diameter

NEMA Type 1 Indoor (Flush and Surface Trims)

NEMA Type 1—Indoor

k

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

—

m

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

n

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

p

2.00 (50.8)

2.50 (63.5)

—

—

—

A

1
1

B

B

B

B

B

B

B

Knockout Diagram

B

A

b

c
h

1

NEMA Type 3R—Outdoor

1

HUB

1
1

e

e

e

c

a

c

0.45 Dia.

1

0.45 Dia.

b b
g c

1

e

c

d

Flush
Trim

3/4

b

i

B

b

Outdoor Boxes
12–42 Circuits 225A Maximum

Box P, PM

B
B

B
A

1
0.45 Dia.

1

i
b

1
1
1

0.45 Dia.

c

b

c

c

d

c
c

b
c

c

c

g

g

c

e

e

c

0.45 Dia.

b

c

b
i

g

b

e

e

e

0.45 Dia.
c

c

d

c
c

c

c

c

g

g

c

e

b

b

c

g

e

e

g

g

g

c
c
c

b

b

b

b

b

b

g
e

e

0.45 Dia.

1

b

b c c

g

c

c

c

c

d

c
c

e

0.45 Dia.
c
c

Box B

1

c
g

e

1

c
c

i
c

g

c
c
c
c

b

b

b

b

b

b

b

b

c
c
c
c

g

g
e

e

e

0.45 Dia.

b

b

b c c

b

g

c

c
c

e

0.45 Dia.
c

c

c

d

b
i

c
c

c

b

Box C, D, E, G, J, K, L

1
1
42

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Contents

Type BR Loadcenters and Circuit Breakers

Description
Overview
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenters . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page

1
1

44
44
47
47
48
65
67
69
72

1
1
1
1
1
1
1
1

Overview

1

Product Selection Guide

1

BR Loadcenters

1

Description

1

Service
Single-phase, three-wire, 120/240 Vac

Three-phase, four-wire, 208Y/120 Vac
Three-phase, three-wire, 240 Vac delta

1
1

Short-Circuit Current Rating
10 kAIC: All single- and three-phase loadcenters 70–225A, 8 to 42 circuits
22 kAIC: All convertible loadcenters using 125A rated Type BRH main breakers or
selected factory installed 125A rated Type BRH main breaker

25 kAIC: All convertible and factory-installed single-phase loadcenters rated
150 and 200A using Type BWH main breakers

1

Main Breaker/Main Lug Loadcenters
Single-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600A
Main lugs: 70, 125, 150, 200, 225, 400, 600A

1

Three-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600A
Main lugs: 100, 125, 150, 200, 225, 400, 600A

1

Convertible Loadcenters
Main breaker: single-phase up to 200A and three-phase up to 225A

1

Main lugs: single-phase up to 200A and three-phase up to 150A

1

Branch Breakers
Types BR, BRH and BRHH: 10–150A. single-, two- and three-pole; selected amperage
available in switching duty, HACR, shunt trip and high magnetic setting
Type GFCB: 15–60A
Types BJ and BJH: 125–225A; two- and three-pole
Type BD Twin: 10–50A; two of one-pole; take one 1-inch (25.4 mm) space

Type BQ and BQC Multibreaker: 15–30A. Two of two-pole or one two-pole and
two one-pole; takes two 1-inch (25.4 mm) spaces
Type BRW: 15–30A; two-pole water heater breakers
Type BRSN: 15–30A; two-pole switching neutral breakers
Type BR 15–100A; two-pole, 240 Vac delta breakers
BR-AFCI arc fault circuit interrupter

1
1
1

Enclosures
NEMA Type 1 indoor
NEMA Type 3R outdoor

1

NEMA 4X
Meets or exceeds UL requirements for indoor or outdoor applications

1

Loadcenter and Breaker Accessories
Branch circuit breaker:
Auxiliary components
Hold-down kits Handle ties
Lockoffs
Lockdogs
Complete line of ground bar kits 5, 10, 14 and 21 circuit, some with additional #2/0 lugs;
each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
Main and sub-feed lugs 125, 150, 225A—two- and three-pole
Shunt trips

Surge protection:
Single-phase plug-on surge protector
Single-phase bottle type surge protector
Three-phase bottle type surge protector
Single-phase whole home surge protector
Universal rainproof conduit hubs
Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm)
Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)
Adapter plate

1
1
1

Bussing
Tin-plated aluminum as standard

1

Limited copper bus panels available

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

43

1.2
1
1
1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Product Description
Loadcenters are enclosures
specifically designed to
house the branch circuit
breakers and wiring required
to distribute power to
individual circuits. They
contain either a main breaker
when used at the service
entrance point or a main lug
when used as a sub-panel
to add circuits to existing
service. The main breaker
protects the main entire
panel and can be used as
a service disconnect. The
branch breakers protect the
wires leading to individual
electrical loads such as
fixtures and outlets.

1
1

Features, Benefits and Functions
Loadcenter Construction
Eaton’s Type BR loadcenters
have standard tin-plated
aluminum bus with a limited
availability of copper bus.
The sum of the handle
ratings connected to any stab
is limited to 150A maximum
on the 100 and 125A
loadcenters, and 200A on
loadcenters with 150A or
higher main bus. NEMA
Type 1 boxes or enclosures
are manufactured from
galvanized steel. Raintight
boxes are manufactured
from galvanized steel, then
finished using an electrostatic
powder coat, baked urethane
paint process.
Neutrals
Eaton’s Type BR loadcenters
feature three types of neutrals:

1

Insulated/Bondable Single/
Split Neutral
Panels are supplied with an
insulated neutral and a bonded
ground. For service entrance
applications, the insulated
neutral must be bonded
utilizing the bonding strap
supplied with the panel. When
used as a service entrance
panel, the bonded ground may
be used as a neutral and/or
ground, unused neutral holes
on either side may be used
for termination of equipment
grounds. For non-service
entrance (sub-panel)
applications, the panel may be
installed with bonding strap
not connected to the neutral
(the bonded ground must be
used as a ground only).

1
1
1
1
1
1
1
1
1
1
1
1

Insulated/Bondable
Single Neutral
Panels are supplied with a
single insulated neutral. For
service entrance applications,
all that is required to bond
the neutral is to loosen the
bonding screw and the
neutral screw directly beside
it, insert the bonding strap
into the neutral bar, and retighten both connections. The
single neutral can be moved
by the contractor to the other
side of the panel, if desired.
When used as a service
entrance panel, unused
neutral connections may be
used for the termination of
equipment grounds. For nonservice entrance (sub-panel).
Insulated/Bondable
Split Neutral
Panels are supplied with twin
insulated neutrals with an
insulated cross strap. For
service entrance applications,
the neutral must be bonded
utilizing the bonding strap
supplied with the panel. For
non-service entrance (subpanel) applications, the panel
may be installed with bonding
strap not connected to the
neutral. Separate ground bars
must be used on non-service
entrance panels.
Grounds
In service entrance
applications where the
neutral is bonded, unused
neutral holes may be used
for terminating ground
conductors. In sub-feed
panels, the neutral must be
isolated (non-bonded), and
ground wires must be
terminated on a separate
ground bar.

1
1
1
1
1
1
44

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

The insulated/bondable
single/split neutral panels
have sufficient terminations
for both ground and neutral
conductors. The insulated/
bondable single split neutral
panels are supplied with a
separate factory-installed
ground bar if the catalog
number contains a “G.” If
not, a separate ground bar
should be installed. Insulated/
Bondable Single Neutral
panels are supplied without
a ground bar (unless
otherwise noted), and ground
bar kits if needed must be
purchased separately.
Neutral and Ground Terminals
The standard terminals on
grounds and neutrals are
rated to accept (3) #14–#10
Cu/Al or (1) #14–4, provided
the cables terminated are of
the same material. For larger
cables, add-on neutral lugs
may be ordered from the
accessories on Page 71.
Note: NEC allows only one
current carrying conductor
per hole on neutrals unless
otherwise noted.

Bottom Fed Loadcenters
For single-phase 225A and
below loadcenters that are
bottom fed, a standard panel
can be rotated 180 degrees
to allow straight-in wiring of
power cables to the main
terminals. Because the main
circuit breaker handle
operates horizontally, the
orientation of the main circuit
breaker handle is consistent
with the requirements of
NEC 2008 Article 240.81.

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Gutter Splicing
Loadcenters are not UL listed
as wiring troughs. Therefore,
gutter splicing of riser cables
to tap off to the main device
is not permitted. Refer to
NEC 2008 Article 312.8.
Fire Rating
Due to the numerous
openings in both loadcenter
boxes and trims, they should
not be mounted in firewalls.
There is no approved method
for sealing the enclosures for
this application.
Date Code
The date of manufacture of
each loadcenter is printed on
the outside of the carton as
well as inside the loadcenter.
On the carton, the date code
is printed on the end carton
label. In the loadcenter, the
date code is located on the
small white label located on
the right side wall (with the
main device on top).

1.2

Surge Protectors
Complete home surge
protection is available in
multiple options, including
a factory-installed option that
provides the highest level of
surge protection in a
residential design. See Tab 3
for more details.

1
1
1
1
1

Circuit Breaker Case
Interrupting Capacity
●
10 kAIC
●
22 kAIC

1
1

Warranty Information
●
10-year limited
loadcenter warranty
●
10-year limited branch
breaker warranty

1
1
1
1
1
1
1

The date code is in the
following format: F # # # &.
The “F” is the numeric
code for the Lincoln, IL
plant, and the three numbers
are the year and week of
manufacturing, e.g., 023. The
“!” sign at the end signifies
the decade of the 2010.
Therefore, the date code
F023& would indicate
that the product was
manufactured in the 23rd
week of 2010. The 1980s
are represented by the “+”
sign and the 1990s are
represented by a “=”
at the end of the code.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

45

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Type BR Loadcenter—BR4040B200
Tangential main knockout for easy installation.
Extra 1.50-inch (38.1 mm) knockout
for bundling of wires.

1
1

Standard 14-3/8 inches (365.1 mm)
wide enclosures fit snugly between
wall studs.
Same size Allen wrench can be used
for phase and neutral lugs.

Drywall marking on enclosure.

1
1
1
1
Commercial grade 25 kAIC rated
main breaker in 150A and above
loadcenters designed for straight-in
wiring that allows for top or
bottom feed.

1
1
1
1
1

Twin neutral design for easier wiring
and balancing of the load, located in
wireway, away from circuit breakers.

Maximum wiring gutter
space for ease of wiring in
compliance with NEC requirements.

Predrilled mounting holes for
ease of installing ground bar kits.

1
1
1

Factory pre-attached neutral
bonding strap.

One piece roll formed metal
backpan with circuit breaker
alignment notches ensures
accurately aligned breaker
and bus stabs.
Maximum variety of concentric
knockouts, at rear and sides.

1
1
1

Six mounting holes (three top, three
bottom) for ease of installation.

1
1
1
1
1
1
1
1
1
1
1
46

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Combination trim has sliding latch
and adjustable deadfront for neat,
clean appearance.

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Standards and Certifications

Catalog Number Selection

UL Listings
All Eaton Type BR
loadcenters are listed under
UL File E52977 except the
2–8 circuit loadcenters,
up through and including
125A, which are listed under
UL File E8741.

Single- and Three-Phase Through 225A

1
3 BR

1
30 42 B C 200

1

Phase
Blank = Single-phase 
3
= Three-phase
Eaton’s Type BR
Loadcenter
Factory Options
SUR = Factory integrated surge
Number of 1-Inch
(25.4 mm) Spaces

1

Construction
Blank = No feed thru lugs 
F
= Feed-through lugs
G
= Ground bar
P
= Current design
NY = NY City gutter space

Main Device
B = Main breaker
L = Main lug
N = Convertible main
H = Main breaker high AIC

1
1

Enclosure
= NEMA Type 3R rainproof
= NEMA Type 1 indoor with
surface trim
F
= NEMA Type 1 indoor with
flush trim
Blank = NEMA Type 1 indoor with
combination trim 
RIS = Riser panel

1

R
S

Bus
Blank = Aluminum bus
C
= Copper bus

Maximum Number
of Circuits

50
70
100
125

1
1
1

Amperes
= 50A
150 = 150A
= 70A
200 = 200A
= 100A
225 = 225A
= 125A

1
1
1

Note
 No character space used.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

47

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single- and Three-Phase 400–600A

3 B 30 42 D F N

1
1

Phase
Blank = Single-phase 
3
= Three-phase

1

Main
Blank = Main lug 
B
= Main breaker

N = Current design
Amperes
D = 400A
E = 600A

Number of 1-Inch
(25.4 mm) Spaces

1
1

Enclosure
F = NEMA Type 1 indoor with
combination trim
S = NEMA Type 1 indoor with
surface trim
R1 = NEMA Type 3R rainproof

Maximum Number
of Circuits

1
1
1
1
1

Example No. 1: BR1224L125G

Example No. 2: BR24L70RP

Example No. 3: 3B4242EFN

Single-phase Type BR
loadcenter rated at 125A with
main lugs, 12 spaces allowing
24 poles, indoor combination
enclosure, aluminum bus and
ground bar.

Single-phase Type BR
loadcenter rated at 70A
with main lugs, two spaces
allowing four poles, rainproof
enclosure with aluminum bus.

Three-phase Type BR
loadcenter rated at 600A
with main breaker, 42 spaces
allowing 42 poles, indoor
combination enclosure.

1
1
1

Product Selection
Single-Phase—Main Circuit Breaker Loadcenters—10/25 kAIC

1
1

BR4040B200

Single-Phase, Three-Wire—120/240 Vac—Factory-Bonded Split Neutral

1

Main
Breaker Type

1

BR
10 kAIC

1

BWH
25 kAIC

1
1

Main
Ampere Rating

Maximum Number
1-Inch (25.4 mm)
Space
Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter Catalog Number
with Combination Cover 

#4–1/0

BR2020B100

100

20

20

Indoor

C2

100

16

24

Indoor

C1

150

30

30

Indoor

G1

200

20

40

Indoor

D1

200

30

40

Indoor

G1

BR3040B200

200

40

40

Indoor

L1

BR4040B200

BR1624B100
#2–300 kcmil
#2–300 kcmil

BR3030B150
BR2040B200

1

Notes
 No character space used.
 Combination style covers may be used in surface or flush applications.

1

All main circuit breaker loadcenters are listed for use as service entrance equipment. Loadcenters are factory-bonded for service entrance applications.
Remove bonding strap for separate neutral and ground bars for sub-feed applications.

1
1
1
1
1
1
1
48

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral

BR816B100

Main
Breaker Type

Main
Ampere Rating

BR
10 kAIC

100

125

BR2030B150

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter Catalog Number
with Combination  or
NEMA Type 3R Cover

#4–1/0 

BR816B100

8

16

Indoor

B1

10

20

Indoor

A1

BR1020B100S11

10

20

Indoor

A1

BR1020B100F11

10

20

Outdoor

B2R

BR1020B100RF 

12

12

Indoor

B2

BR1212B100

12

20

Indoor

B2

BR1220B100

12

24

Outdoor

B2R

BR1224B100R 

16

16

Indoor

C1

BR1616B100

16

20

Indoor

C1

BR1620B100

16

24

Outdoor

C1R

BR1624B100R 

20

24

Outdoor

C3R

BR2024B100R 

30

30

Indoor







#4–2/0

BR1624B125

16

24

Indoor

C1

20

24

Indoor

C1

1
1
1
1
1



20

24

Outdoor

C3R

100

20

24

Indoor

C2

#2/0–300 kcmil

BR2024H100 

BWH 
25 kAIC

150

8

16

Outdoor

C3R

#2–300 kcmil

BR816B150RF 

16

30

Indoor

C4

BR1630B150

20

30

Indoor

C4

BR2030B150

20

30

Outdoor

D1R

BR2030B150R 

20

40

Indoor

D1

BR2040B150

20

40

Outdoor

D1R

BR2040B150R 

24

30

Indoor

G1

BR2430B150

30

30

Outdoor

G1R

BR3030B150R 

30

40

Indoor

G1

4

8

Outdoor

8R

8

16

Outdoor

C3R

BR816B200RF 

16

32

Indoor

C4

BR1632B200

20

40

Outdoor

D1R

BR2040B200R 

24

40

Indoor

G1

BR2440B200

30

40

Outdoor

G1R

BR3040B200R 

40

40

Outdoor

L1R

BR4040B200R 

42

42

Indoor

L2

42

42

Outdoor

L2R

225

1
1

BRH 
22 kAIC

200

1
1
1
1
1
1
1

BR3040B150
#2–300 kcmil

#1–250 kcmil

1
1

BR2024B125
BR2024B125R

1

BR48B200RF 	

1
1
1
1

BR4242B225

1

BR4242B225R 

Notes
 Combination style covers may be used in surface or flush applications.
 Wire range size for BR1020B100SP is #6–#1 Cu/Al.
 Includes through-feed lugs for both phase and neutral conductors.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 See copper bus offering, Page 58.
 22 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch breakers are used in series with Type BRH main breaker.
 25 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch circuit breakers are used in series with Type BWH main breaker.
 Supplied with adapter plate to use DS Group1 hubs on Page 71. If 2.50-inch (63.5 mm) hub is needed, remove adapter and use ARP00007CH25 hub.
	 Neutral is bonded—suitable for service entrance only—cannot be converted for sub-feed application.
All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with neutral bonding strap preattached. The maximum rating of the
panel is the main circuit breaker rating when used as service entrance equipment. Ground bar kits priced separately. See Page 71.

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

49

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Main Circuit Breaker Loadcenters—10/22/25 kAIC
BR3030BC100

1
1
1
1
1

Main Circuit Breaker Loadcenters—With Copper Bus—Single-Phase Three-Wire—120/240 Vac—
Factory-Bonded Split Neutral
Main
Breaker Type

Main
Ampere Rating

BR
10 kAIC

100

BRH
22 kAIC 
BWH
25 kAIC

Maximum Number
1-Inch (25.4 mm)
Spaces

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter Catalog Number
with Combination Cover 

20

20

Indoor

C2

#4–1/0

BR2020BC100

30

Indoor

D1

#4–1/0

BR3030BC100

100

30

30

Indoor

D1

#4–1/0

BR3030HC100

150

30

30

Indoor

G1

#2–300 kcmil

BR3030BC150

200

20

40

Indoor

D1

#2–300 kcmil

BR2040BC200

30

40

Indoor

G1

#2–300 kcmil

BR3040BC200

40

40

Indoor

L1

#2–300 kcmil

BR4040BC200

Main Circuit Breaker Loadcenters—10/22 kAIC

1
1

Circuits

Box
Size

30

1
1

Enclosure
Type

B4242DFN

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral

1

Main
Breaker
Type

Main
Ampere
Rating

1

DK 

1
1

Commercial Loadcenter
Catalog Number 
With Flush or
With
NEMA Type 3R Cover
Surface Cover

Spaces

Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

300

42

42

Indoor

24

(2) #3/0–250 kcmil

BR304242F

BR304242S

400

42

42

Indoor

24

(2) #3/0–250 kcmil

B4242DFN

B4242DSN

42

42

Outdoor

47

(2) #3/0–250 kcmil

B4242DR1N 

—

42

42

Indoor

24

(2) #3/0–500 kcmil

B4242EFN

B4242ESN

1
HLD 	

Maximum Number
1-Inch (25.4 mm)

600

Notes
 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with neutral bonding strap preattached. The maximum rating of the
panel is the main circuit breaker rating when used as service entrance equipment.
 Ground bar kits priced separately. See Page 71.
 22 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch breakers are used in series with Type BRH main breaker.
 Ground bar kits priced separately. See Page 71.
 The maximum rating of the panel is the main circuit breaker rating when used as service entrance equipment.
 Door lock and key included with loadcenter.
 Type DK main circuit breaker is rated 65 kAIC at 240 Vac and allows a 22 kAIC series rating on the panel when Types BR, BD and BJ branch circuit breakers are used.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
	 Type HLD main circuit breaker is rated 65 kAIC at 240 Vac. Type HLD circuit breaker is not series rated with Types BR, BD and BJ branch circuit breakers.

1
1
1
1

Box sizes Pages 85 through 88.

1
1
1
1
1
1
1
1
1
1
50

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase—Main Lug Loadcenters

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral
Main
Ampere Rating
Surface

Outdoor

70

125
Flush

Outdoor

Surface (No Door)

Flush (No Door)

Outdoor

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

Trim Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

2

4

Indoor

Surface (no door)

5

#8–#2

2

4

Indoor

Surface (no door)

5

1
Loadcenter
Catalog Number
BR24L70SP 

1
1

BR24L70SGP 


2

4

Outdoor

—

5R

BR24L70RP

2

4

Indoor

Flush (no door)

5

BR24L70FP 

2

4

Indoor

Flush (no door)

5

2

4

Indoor

Surface (no door)

6

BR24L70FGP

2

4

Outdoor

—

6R

BR24L125RP 

2

4

Outdoor

—

6R

BR24L125RSEP 

2

4

Outdoor

—

6R

BR24L125RSE2P 

2

4

Indoor

Flush (no door)

6

BR24L125FP 

4

8

Indoor

Surface (no door)

7

4

8

Indoor

Surface (no door)

7

BR48L125SGP 	

4

8

Outdoor

—

7R

BR48L125RP 	

4

8

Indoor

Flush (no door)

7

BR48L125FP 	

4

8

Indoor

Flush (with door)

7

BR48L125FDP 	

4

8

Indoor

Flush (no door)

7

6

12

Indoor

Surface (no door)

7

6

12

Indoor

Surface (no door)

7

BR612L125SGP 

6

12

Indoor

Surface (with door)

7

BR612L125SDP 

6

12

Indoor

Surface (with door)

7

BR612L125SDGP 

6

12

Outdoor

—

7R

BR612L125RP 

6

12

Indoor

Flush (no door)

7

BR612L125FP 

6

12

Indoor

Flush (no door)

7

BR612L125FGP 

6

12

Indoor

Flush (with door)

7

BR612L125FDP 

6

12

Indoor

Flush (with door)

7

BR612L125FDGP 

8

16

Indoor

Surface (no door)

7

8

16

Indoor

Surface (no door)

7

BR816L125SGP 

8

16

Indoor

Surface (with door)

7

BR816L125SDP 

8

16

Indoor

Surface (with door)

7

BR816L125SDGP 

8

16

Outdoor

—

7R

BR816L125RP 

8

16

Indoor

Flush (no door)

7

BR816L125FP 

8

16

Indoor

Flush (no door)

7

BR816L125FGP 

8

16

Indoor

Flush (with door)

7

BR816L125FDP 

8

16

Indoor

Flush (with door)

7

BR816L125FDGP 

#14–1/0

#14–1/0

1



1

BR24L125SP 

1
1
1

BR48L125SP 	

1
1

BR48L125FGP 	
#14–#1

#14–#1

1

BR612L125SP 

1
1
1
1
1

BR816L125SP 

1
1
1
1

Notes
 Ground bar kits priced separately. See Page 71.
– For 2/4 circuit loadcenters, use GBK5 or GBK520 ground bar.
– For 4/8, 6/12 and 8/16 circuit loadcenters, use GBK10 ground bar.
– Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters.
 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
 Ground bar GBK5 is installed.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 CSA and UL approved.
 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/Al.
 For use as service entrance applications only.
 Neutral/ground holes (6) #14–6 and (3) #14–1/0 AWG Cu/Al.
	 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are provided
and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
 Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used
as a lighting and appliance panelboard (see Article 408.34 of the NEC).
 Ground bar GBK10 is installed.
 Ground bar GBK14 is installed.

1
1
1
1
1
1
1
1

Box sizes Pages 85 through 88.

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1

51

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase—Main Lug Loadcenters

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral, continued
Main
Ampere Rating

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter Catalog Number
with Combination or
NEMA Type 3R Cover 

125

12

12

Indoor

B1

#6–2/0

BR1212L125 

1

12

24

Indoor

B1

BR1224L125 

12

24

Indoor

B1

BR1224L125G 

1

12

24

Indoor

B1

BR1224L125DG 

12

24

Outdoor

B1R

BR1224L125R 

16

16

Indoor

B2

BR1616L125 

16

24

Indoor

B2

BR1624L125 

16

24

Indoor

B2

BR1624L125G 

1

16

24

Outdoor

B2R

BR1624L125R 

20

20

Indoor

C1

BR2020L125 

1

20

24

Indoor

C1

BR2024L125 

20

24

Indoor

C1

BR2024L125G 

20

24

Outdoor

C1R

BR2024L125R 

24

24

Indoor

C2

BR2424L125 

24

24

Indoor

C2

BR2424L125G 

16

30

Indoor

C2

20

30

Indoor

C2

8

16

Outdoor

B2R

12

24

Indoor

B2

BR1224L200 	

12

24

Outdoor

B2R

BR1224L200R 	

1

20

40

Indoor

C2

BR2040L200 	

20

40

Indoor

C2

BR2040L200G 	

1

20

40

Outdoor

C3R

BR2040L200R 	

24

40

Indoor

C4

BR2440L200 	

30

40

Indoor

D1

BR3040L200 	

30

40

Indoor

D1

BR3040L200G 	

30

40

Outdoor

D1R

BR3040L200R 	

1

40

40

Indoor

G1

BR4040L200 	

40

40

Indoor

G1

BR4040L200G 	

1

40

40

Outdoor

G1R

BR4040L200R 	

42

42

Indoor

L1

42

42

Outdoor

L1R

1
1

BR1224L125

1
1

1
1
1
1

150

BR1224L200

200

1

1
1

225

1

#1–300 kcmil

BR1630L150 	
BR2030L150 	

#1–300 kcmil

#1–300 kcmil

BR816L200RF 

BR4242L225 
BR4242L225R 

Notes
 Ground bar kits priced separately unless otherwise noted. See Page 71.
 Has notch for BREQS125 hold-down kit.
 Single, movable neutral is provided.
 Combination cover style.
 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
 Ground bars GBK5 and GBK520 installed.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 Ground bar GBK1220 installed.
	 Has notch for BRHDK125 hold-down kit.
 Includes through-feed lugs for both phase and neutral conductors.

1
1
1
1
1
1
1
1
52

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase—Main Lug Loadcenters, Non-Metallic

2460SNM

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral
Main
Ampere Rating
40 

60

BR816LC125FDP

1

Maximum Number
1-Inch (25.4 mm)

Enclosure
Type

Trim Type

Box
Size

Indoor

Flush (no door)

2

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

1

Loadcenter
Catalog Number

Spaces

Circuits









Indoor

Surface (no door)

2

2

4

Indoor

Flush (no door)

2

2

4

Indoor

Surface (no door)

2

2460SNM

2

4

Indoor

Flush (no door)

2

2460FGNM 

2

4

Indoor

Surface (no door)

2

2460SGNM 

2

4

Outdoor

—



2460RNM



1

TT120FLGNM 
TT120SLGNM

#14–2



1

2460FNM

1
1
1
1

Single-Phase Three-Wire—120/240 Vac—Single Neutral with Copper Bus
Main
Ampere Rating
125

Maximum Number
1-Inch (25.4 mm)

Trim Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

#14–1

BR816LC125SDP

Spaces

Circuits

Enclosure
Type

8

16

Indoor

Surface (with door)

7

8

16

Indoor

Flush (with door)

7

1
1

BR816LC125FDP

1
1

Notes
 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
 This device has no main lugs. A Type BR or BD breaker is required to be backfed to supply power to branch breakers. This device is single-phase 120 Vac only.
With the use of three Type BR breakers there are two branch circuits available. With the use of three Type BD breakers there are five branch circuits available.
 Includes GB4NM ground bar.
 2460 RNM uses the non-metrical ACD enclosure. See ACD Section for dimensions.

1
1
1

Box sizes Pages 85 through 88.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

53

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase—Main Lug Loadcenters—400 and 600A
4242DFN

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral
Maximum Number
1-Inch (25.4 mm)

1

Main
Ampere Rating

1

400

1
1
1

600

Spaces

Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs
(1) #4/0–750 kcmil
or
(2) #3/0–400 kcmil

Commercial Loadcenter
Catalog Number 
With Flush or NEMA
Type 3R Cover

With Surface
Cover

—

1224DSN 

1224DR1N 

—
2442DSN

12

24

Indoor

19

12

24

Outdoor

42

24

42

Indoor

20

—

42

42

Indoor

22

4242DFN

4242DSN

42

42

Outdoor

46

4242DR1N 

—

42

42

Indoor

22

—

4242ESN

(2) #2–500 kcmil

1
1
1

Three-Phase—Main Circuit Breaker Loadcenters—10 kAIC

3BR4242B200

1

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral
Main
Breaker Type

1
1
1

Main
Ampere
Rating

BR
10 kAIC

100

CC
10 kAIC

150

200

1
1
1

225

1

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter Catalog Number 
(With Combination or
NEMA Type 3R Cover)

#4–1/0

3BR1224B100

12

24

Indoor

C1

12

24

Outdoor

C1R

3BR1224B100R 

30

42

Indoor

L1

30

42

Outdoor

L1R

30

42

Indoor

L1

30

42

Outdoor

L1R

3BR3042B200R 

42

42

Indoor

L2

3BR4242B200

42

42

Outdoor

L2R

3BR4242B200R 

42

42

Indoor

L2

42

42

Outdoor

L2R

#1–3/0

3BR3042B150
3BR3042B150R 

#1–250 kcmil

#1–300 kcmil

3BR3042B200

3BR4242B225
3BR4242B225R 

Notes
 Ground bar kits priced separately unless otherwise noted. See Page 71.
 Has notch for BRHDK125 hold-down kit.
 Ground bar GBK8 installed.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap pre-attached (commercial loadcenters
do not have a pre-attached bonding strip). The maximum main rating of the panel is the main circuit breaker rating when used as service entrance equipment.
 Ground bar kits priced separately. See Page 71.
 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page 71.

1
1
1
1
1
1
1
1
1
1
1
1
54

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Three-Phase—Main Circuit Breaker Loadcenters—22/65 kAIC

1

Three-Phase, Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral
Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

DK 
22 kAIC

400

42

42

42

LD 

600

42

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Commercial Loadcenter
Catalog Number 
With Combination or NEMA Type 3R Cover

Indoor

24

(2) #3/0–250 kcmil

3B4242DFN

42

Outdoor

47

42

Indoor

24

1
1
1

3B4242DR1N 
(2) #3/0–500 kcmil

1

3B4242EFN

1

Three-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—22/100 kAIC

1
3BR4242H200

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral
Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
1-Inch (25.4 mm)
Spaces
Poles

Enclosure
Type

BRH
22 kAIC 	

100

12

24

CHH
100 kAIC 

150

30

42

CHH
100 kAIC 

200

1

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter
Catalog Number 
with Combination Cover with Surface Cover

Indoor

C1

#4–1/0

3BR1224H100

3BR1224H100S

1

Indoor

L1

#1–250 kcmil

3BR3042H150

3BR3042H150S

1

#1–250 kcmil

3BR3042H200

3BR3042H200S

3BR4242H200

3BR4242H200S

1

30

42

Indoor

L1

42

42

Indoor

L2

1

Notes
 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap pre-attached (commercial loadcenters
do not have a pre-attached bonding strip). The maximum main rating of the panel is the main circuit breaker rating when used as service entrance equipment.
 Ground bar kits priced separately. See Page 71.
 Door lock and key included with loadcenter.
 Type DK main circuit breaker is rated 65 kAIC at 240 Vac and allows a 22 kAIC series rating on the loadcenter when Types BR, BD and BJ branch circuit breakers
are used.
 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 The LD main circuit breaker is rated 65 kAIC at 240 Vac. Type LD circuit breaker is not series rated with Types BR, BD and BJ branch circuit breakers.
 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap pre-attached.
 Ground bar kits priced separately.
	 22 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFGB branch breakers are used with BRH main.
 100 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFGB branch breakers are used with CHH main.

1
1
1
1
1
1

Box sizes Pages 85 through 88.

1
1
1
1
1
1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

55

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Three-Phase—Main Lug Loadcenters

3BR1224L125

1

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral
Main
Ampere Rating

1

100

1

125

1
150

Maximum Number
1-Inch (25.4 mm)

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter Catalog Number 
(With Combination or
NEMA Type 3R Cover)

#14–1/0

3BR3L100S 

Spaces

Circuits

Enclosure
Type

3

3

Indoor

9

3

3

Outdoor

9R

12

24

Indoor

C1

12

24

Outdoor

C1R

3BR3L100R 
#6–2/0

3BR1224L125 
3BR1224L125R 

24

42

Indoor

D1

24

42

Outdoor

D1R

12

24

Indoor

C4

12

24

Outdoor

C3R

3BR1224L200R 

1

30

42

Indoor

G1

3BR3042L200

30

42

Outdoor

G1R

3BR3042L200R 

1

42

42

Indoor

L1

3BR4242L200

42

42

Outdoor

L1R

42

42

Indoor

L1

42

42

Outdoor

L1R

1
200

1

1

225

1
1

34242DFN

#1–300 kcmil

3BR2442L150
3BR2442L150R 

#1–300 kcmil

3BR1224L200 

3BR4242L200R 
#1–300 kcmil

3BR4242L225
3BR4242L225R 

Three-Phase, Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral

1

Maximum Number
1-Inch (25.4 mm)

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Commercial Loadcenter
Catalog Number 
With Flush or
NEMA Type 3R Cover

With
Surface Cover

—

—

—

—

—

—

1

Main
Ampere Rating

Spaces

Circuits

Enclosure
Type

Box
Size

1

400

18

36

Indoor

19

18

36

Outdoor

43

24

42

Indoor

19

42

42

Indoor

22

34242DFN

34242DSN

42

42

Outdoor

46

34242DR1N 

—

42

42

Indoor

22

—

34242ESN

1
1
600

1

(1) 250–750 kcmil
or
(2) #3/0–250 kcmil

(2) #2–500 kcmil

Notes
 Ground bar kits priced separately. See Page 71.
 Surface cover only.
 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 Has notch for BREQS125 hold-down kit.
 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
 Door lock and key included with loadcenter.

1
1
1

Box sizes Pages 85 through 88.

1
1
1
1
1
1
1
1
56

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Convertible Loadcenters MCB or MLO—Base Units and Main Devices 10/22/25 kAIC,
Complete Assembly Consists of: Loadcenter and Either Main Breaker Kit or Main Lug Kit

1

Note: Interrupting rating depends on main circuit breaker selected.

BR3040N200

1
1

Base Units—Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral
Main
Ampere Rating 

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

Box
Size

125 

12

24

Indoor

B2

12

24

Outdoor

B2R

16

24

Indoor

C1

BR1624N125 

16

24

Outdoor

C1R

BR1624N125R 

20

24

Indoor

C2

BR2024N125 

200 

Wire Size Range
Cu/Al 60°C or 75°C
for Main

Loadcenter Catalog Number
With Combination or NEMA
Type 3R Cover 

1

See main breaker and
main lug kit tables
Page 59.

BR1224N125 

1

BR1224N125R 

20

24

Outdoor

C3R

BR2024N125R 

8

16

Outdoor

C3R

BR816N200RF 	

12

24

Indoor

C4

BR1224N200 

1
1
1
1



12

24

Outdoor

C3R

BR1224N200R

16

32

Indoor

C4

BR1632N200 


20

40

Indoor

D1

BR2040N200

20

40

Indoor

D1

BR2040N200G 

20

40

Outdoor

D1R

BR2040N200R 

20

40

Outdoor

D1R

BR2040N200RG 

24

40

Indoor

G1

BR2440N200 

1
1
1
1



30

40

Indoor

G1

BR3040N200

30

40

Indoor

G1

BR3040N200G 

30

40

Outdoor

G1R

BR3040N200R 

30

40

Outdoor

G1R

BR3040N200RG 

40

40

Indoor

L1

BR4040N200 

40

40

Indoor

L1

BR4040N200G 

40

40

Outdoor

L1R

BR4040N200R 

40

40

Outdoor

L1R

BR4040N200RG 

1
1
1
1
1

Notes
 The maximum rating of the loadcenter is the main circuit breaker rating when used as service entrance equipment.
 100, 125 and 200A convertible base unit catalog numbers include interior, box and cover only. Main devices and accessories must be ordered separately for field
installation. All convertible base units are listed as suitable for use as service entrance equipment when used per Article 384 of the NEC.
 Ground bar kits priced separately except as noted, refer to Page 71.
 For main breaker, use Type BR. For main lug use Type BRSF.
 BREQS125 hold-down screw comes with loadcenter for back-fed Types BR and BRH main circuit breakers.
 Convertible to maximum of 100A main circuit breaker and 125A main lug.
 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 For main breaker, use Type BW or BWH. For main lug, use Type BRL.
	 Includes through-feed lugs for both phase and neutral conductors.
 No hold-down provisions for back-fed Types BR and BRH main circuit breakers.
 Includes GBK2120 ground bar.

1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

57

1.2
1

3BR3030N100

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Base Units—Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Neutral

1

Main
Ampere Rating 

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

Box
Size

1

100 

30

30

Indoor

D1

30

30

Outdoor

D1R

1

125 

12

24

Indoor

C1

3BR1224N125 

12

24

Outdoor

C1R

3BR1224N125R 

Wire Size Range
Cu/Al 60°C or 75°C
for Main

Loadcenter Catalog Number 
(With Combination or
NEMA Type 3R Cover)

See main breaker and
main lug kit tables
next page.

3BR3030N100 
3BR3030N100R 

1
1

Convertible Loadcenters—With Copper Bus 10/22/25 kAIC

1
1

BR3040NC200

Convertible—Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral
Main
Ampere Rating

1

125
10/22 kAIC 

1
1

200
10/25 kAIC 

1
1
1
1

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

Box
Size

12

24

Indoor

B2

12

24

Outdoor

B2R

20

24

Indoor

C2

BR2024NC125 

20

24

Outdoor

C3R

BR2024NC125R 

20

40

Indoor

D1

BR2040NC200

20

40

Outdoor

D1R

BR2040NC200R 

30

40

Indoor

G1

BR3040NC200

30

40

Outdoor

G1R

BR3040NC200R 

40

40

Indoor

L1

BR4040NC200

40

40

Outdoor

L1R

BR4040NC200R 

Wire Size Range
Cu/Al 60°C or 75°C
for Main

Loadcenter Catalog Number
with Combination or
NEMA Type 3R Cover 	

See main breaker
and main lug kit tables
on Page 59.

BR1224NC125 
BR1224NC125R 

Notes
 The maximum rating of the loadcenter is the main circuit breaker rating when used as service entrance equipment.
 100, 125 and 200A convertible base unit catalog numbers include interior, box and cover only. Main devices and accessories must be ordered separately for field installation. All
convertible base units are listed as suitable for use as service entrance equipment when used per Article 384 of the NEC.
 Ground bar kits priced separately, refer to Page 71.
 For main breaker, use Type BR. For main lug, use Type BRSF.
 BREQS125 hold-down screw comes with loadcenter for back-fed Types BR and BRH main circuit breakers.
 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 Convertible to maximum of 100A main circuit breaker and 125A main lug.
 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
	 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap preattached. The maximum main
rating of the loadcenter is the main breaker rating when used as service entrance equipment.
 Interrupting rating depends on main circuit breaker selected. See Page 71 for mains.
 For main breaker, use Type BW or BWH. For main lug, use Type BRL.
 Hold-down screw BREQS125 comes with loadcenter for back-fed Types BR and BRH main circuit breakers.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
58

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Convertible Loadcenters MCB or MLO—Base Units and Main Devices 10/22/25 kAIC,
Complete Assembly Consists of: Loadcenter and Either Main Breaker Kit or Main Lug Kit

1

Note: Interrupting rating depends on main circuit breaker selected.
BW2200

Main Devices—Two- and Three-Pole
Main Circuit Breakers—120/240 Vac or
208Y/120 Vac or 240 Vac
Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

10 kAIC
Catalog
Number

1
Main Devices—Two- and Three-Pole
Main Lug Kits—120/240 Vac or
208Y/120 Vac or 240 Vac

BRL200

22/25 kAIC
Catalog
Number 

Ampere
Rating

Catalog
Number

#4–1/0

BR2100

BRH2100

125

#6–2/0

BRSF125

#1–300 kcmil

BRL200

110

#4–1/0

BR2110

BRH2110

150

125

#4–2/0

BR2125

BRH2125

175

#1–300 kcmil

BRL200

125

#2–300 kcmil

BW2125

BWH2125

200

#1–300 kcmil

BRL200

150

#2–300 kcmil

BW2150

BWH2150

Three-Pole

175

#2–300 kcmil

BW2175

BWH2175

150

#6–3/0

3BRSF150

200

#2–300 kcmil

BW2200

BWH2200

BR3100

BRH3100

Three-Pole
100

1
1

Two-Pole

Two-Pole
100

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

1

#1

1
1
1
1

Main Circuit Breaker with Accessory
Example: BW22005R01 (Put description with catalog number on
order. See Page 83.)

1
1
1

Spa Panels

1
Spa Panel—Meets NEC Article 680.40 Through 680.43—Requirements for GFCI Protection

1

Main
Ampere Rating

Maximum Number
1-Inch (25.4 mm)
Space
Poles

Enclosure
Type

Box
Size

Wire Size Range Cu/Al 60°C
or 75°C for Main Lugs

Catalog
Number

40

—

—

Outdoor

5R

#8–#2

BR40SPA 

50

—

—

Outdoor

5R

#8–#2

BR50SPA 

1
1
1

Notes
 Series combination rating with Types BD, BR, BQ, BQC and GFCB is 22 kAIC with BRH main and 25 kAIC with BWH main.
 Includes a GFCB240 breaker, factory installed.
 Includes a GFCB250 breaker, factory installed.

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

59

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase and Three-Phase Circuit Breaker Unit Enclosures—10/25 kAIC
Circuit Breaker Unit
Enclosures

Type ECB Circuit Breaker Unit Enclosure—Order Type BW and BWH Circuit Breaker Separately—
Unit Enclosure Includes Lug Tree Kit
Main
Ampere Rating

1

Unit Enclosure
Type

Mounting
Type

Circuit Breaker
Type

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

Single-Phase Three-Wire—240 Vac Maximum

1
1

225

Indoor

Flush

BW, BWH



ECB225F 

225

Indoor

Surface

BW, BWH



ECB225S 

225

Outdoor

—

BW, BWH



ECB225R 

1
1

BWH2200

1

Types BW and BWH Circuit Breakers
120/240 Vac—25 kAIC for Use in
Type ECB Unit Enclosures
Ampere
Rating

1

Two-Pole
Breakers
10 kAIC

Wire Size Range
Cu/Al 60°C or 75°C
for Line Terminals

1

125

BW2125

150

BW2150

BWH2150

1

175

BW2175

BWH2175

200

BW2200

BWH2200

225

BW2225

BWH2225

1

#2–300 kcmil

Two-Pole
Breakers
25 kAIC
BWH2125

1
BW/BWH Lug Tree Kit for Replacement
Purposes Only for Use in Type ECB
Unit Enclosures

1
1
1

Ampere
Rating

1

225

1

Description
For use on
125, 150, 175, 200
and 225A BW and
BWH breakers

Wire Size
Range Cu/Al
60°C or 75°C
for Line
Terminals

Catalog
Number

#2–300 kcmil

MCBK225

Wire/Application Chart
Wire/Application

Maximum
Wire Size

Maximum
Ampere Rating

Aluminum—standard

250 kcmil

200

Aluminum—service entrance

250 kcmil

225

Copper—standard and service entrance

250 kcmil

225

Notes
 Wire size is determined by the circuit breaker installed in enclosure. Maximum wire size and
ampere rating is determined by Wire/Application Chart.
 Order circuit breaker separately.
 One ground lug accepting (1) #14–#2 is factory installed. Also, there are pre-drilled holes to
accept a GBK5 ground bar.
 Approved for service entrance.
 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page 71.
 Add suffix indicated to end of breaker catalog number.
Box sizes Pages 85 through 88.

1
1

Shunt Trips, Auxiliary and Alarm Contacts

1

Description

Catalog Number
Suffix Adder 

Shunt Trip for Types BW/BWH

1
1

12V

SR12

24V

SR24

120V

SR01

Auxiliary Contact for Types BW/BWH

1
1

1NO and 1NC

AL1

2NO and 2NC

AL2

Alarm Contacts for Types BW/BWH

1

Types BW/BWH

CR1

Alarm Contacts for Type GFCB (Single-Pole)

1
1

Alarm contact for GFCB (single-pole)

W1

1NO and 1NC

W2

1
1
60

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase and Three-Phase Circuit Breaker Unit Enclosures—10/25 kAIC

1

Type ECC Circuit Breaker Unit Enclosure—Order Type CC Circuit Breaker Separately
Main Ampere
Rating

Unit Enclosure
Type

Mounting
Type

Circuit
Breaker Type

Wire Size Range
Cu/Al 60°C or 75°C

ECC225F

1

Catalog
Number

1

Single- and Three-Phase—240 Vac Maximum

CCV2200

225

Indoor

Flush

CC/CCV



225

Indoor

Surface

CC/CCV



ECC225S 

225

Outdoor

—

CC/CCV



ECC225R 

Type CC and CCV Circuit Breaker
240 Vac—10 kAIC for Use in Type ECC Unit
Enclosures
Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C
for Line Terminals

Type CCV and
CC 10 kAIC
Catalog Number

Two-Pole
100

#4–4/0

CCV2100

CCV2175

200

CCV2200

225

CCV2225

Three-Pole
#4–4/0

150
175

Maximum
Wire Size

Maximum
Ampere Rating

Aluminum—standard

250 kcmil

200

Aluminum—service entrance

250 kcmil

225

Copper—standard and service entrance

250 kcmil

225

1
1
1

CC3175
CC3200

225

CC3225

Shunt Trips and Auxiliary Contacts
Description

1
1
1
1
1
1

CC3150
#2/0–300 kcmil

200

1
1


Volts

Catalog Number
Suffix Adder 

CC

12 DC

SR12

CC

24 DC

SR24

CC

120 AC

SR01

CC

208 AC

SR08

CC

240 AC

SR02

CCV

48–127 AC/48–60 DC

SR01

CCV

9–24 AC/12–24 DC

SR24

Type

Wire/Application

Box sizes Pages 85 through 88.

CCV2150

125

1

Wire/Application Chart

CC3125

150

100

1

CC3100

CCV2125

#2/0–300 kcmil

1

Notes
 Order circuit breaker separately.
 One ground lug accepting (1) #14–#2 is factory installed. Also, there are pre-drilled holes to
accept a GBK5 ground bar.
 Approved for service entrance.
 Rainproof panels are furnished with hub closures plates. For rainproof hubs, refer to
Page 71.
 Wire size is determined by the circuit breaker installed in enclosure. Maximum wire size and
ampere rating is determined by the Wire/Application Chart.
 CCV breakers are two-pole only.
 Add suffix indicated to end of breaker catalog number.

125

175



1
1

Shunt Trip

1
1
1
1
1

Auxiliary Contact
CC 1NO and 1NC —

AL1

1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

61

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Commercial Loadcenters—Indoor Enclosures
Main Circuit Breaker, Main Lug and Convertible, New York City Approved
Single-Phase and Three-Phase

1
1
1

BR4242B200NY
With 3BR42FTNY
Cover Installed

1

Single-Phase Main Circuit Breaker—Factory Installed
Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or
75°C for Main Breaker

Loadcenter
Catalog Number

Loadcenter Cover
Catalog Number
Flush
Surface

Single-Phase Three-Wire—120/240 Vac Insulated/Bondable Neutral
CC 10 kAIC

1

200

42

42

Indoor

A

#1–300 kcmil

BR4242B200NY 

3BR42FTNY

Box
Size

Wire Size Range
Cu/Al 60°C or
75°C for Main Lugs

Loadcenter
Catalog Number

Loadcenter Cover
Catalog Number
Flush
Surface

3BR42STNY

1
1
1
1

BR4242L225NY
With 3BR42FTNY
Cover Installed

1

Single-Phase Main Lugs—Factory Installed
Main Lug
Ampere
Rating

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

Single-Phase Three-Wire—120/240 Vac Insulated/Bondable Neutral
225

1

42

42

Indoor

A

#1–300 kcmil

BR4242L225NY 

3BR42FTNY

Box
Size

Wire Size Range
Cu/Al 60°C or
75°C for Main Breaker

Loadcenter
Catalog Number

Loadcenter Cover
Catalog Number
Flush
Surface

3BR4242N225NY 

3BR42FTNY

3BR42STNY

1
1
1

3BR4242N225NY

1

Three-Phase Convertible Loadcenters
Main
Ampere
Rating

1

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

Three-Phase Four-Wire—120/240 Vac Insulated/Bondable Neutral

1

225

42

42

Indoor

B

#1–300 kcmil

1
1
1
Three-Phase Main Breaker Kits

1
1
1

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

Main Breaker Kit
10 kAIC

150

#4–4/0
#2/0–300 kcmil

CC3150N

175

1
1

CC3175N

200

CC3200N

225

CC3225N

Three-Phase Main Lugs Kit

1

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

Main
Lugs Kit

1

225

#2/0–300 kcmil

3BRL225

1

Note
 Approved for 150A and up for residential services in New York City.

1
62

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

3BR42STNY

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Technical Data and Specifications
General
A. The Contractor shall
furnish and install
deadfront loadcenters
incorporating circuit
breakers of the number,
rating and type as
specified herein and
as shown on the
contract drawings.

Ratings
A. Loadcenters shall be
rated for 120/240 Vac
and shall have shortcircuit ratings as shown
on the drawings or
as herein scheduled,
but not less than
10,000 amperes rms
symmetrical.

B. The loadcenter and all
components shall be
designed, manufactured
and tested in accordance
with the latest applicable
standards of UL, NEMA
and NEC including:

B. Circuit breakers shall be
a minimum of 125A
frame. Circuit breakers
15 through 125A trip size
shall take up the same
pole spacing.

1. UL 67—Standards
for Panelboards.
2. UL 50—Standards for
Cabinets and Boxes.
3. UL 489—Standards for
Molded Case Circuit
Breakers.
4. UL 869—Standards for
Service Equipment.
5. Federal Specification WC 375B—Circuit
Breakers.
6. Federal Specification WC P115b—Panel
Power Distribution
Type 1, Class 2.
Qualifications
A. The manufacturer of the
loadcenter shall be the
manufacturer of the
circuit breaker within
the loadcenter.
B. For the equipment
specified herein, the
manufacturer shall be
ISO 9000 certified.
C. The manufacturer of
this equipment shall
have produced similar
electrical equipment
for a minimum period
of seven (7) years.
Manufacturers
A. Eaton.

C. Loadcenters shall be
labeled with a UL shortcircuit rating. When
series combination
ratings are applied
with integral or remote
upstream devices, a label
shall be provided. Series
combination ratings shall
cover all trip ratings of
installed frames. It shall
state the conditions of
the UL series ratings
including:
1. Size and type of
upstream device.
2. Branch devices that can
be used.
3. UL series short
circuit rating.
Construction
A. All interiors, with the
exception of the branch
circuit breakers, shall
be completely factory
assembled with main
breakers, main lugs,
or no main device.
B. Interiors shall be
designed so that circuit
breakers can be replaced
without disturbing
adjacent units and
without removing the
main bus connectors and
shall be designed so that
circuits may be changed
without machining,
drilling, or tapping.

C. Physical means shall be
provided to prevent the
installation of more
overcurrent devices than
that number for which
the enclosure was
designed, rated and
approved. Half-size
breakers shall have a
UL listed rejection tab
over the line terminals.
Loadcenter interiors
must have notched stabs
to accept these rejection
tab class CTL breakers, if
required and approved.
Bus
A. Bus bars for the main and
cross connectors shall be
[tin-plated aluminum]
[copper] in accordance
with Underwriters
Laboratories standards.
Busing shall be braced
throughout to conform to
industry standard practice
governing short-circuit
stresses in loadcenters.
Note: Note to spec writer—
select one (copper available
in limited ratings).

B. Neutral busing shall
have a suitable lug for
each outgoing feeder
requiring a neutral
connection of same
ampacity as branch.
Wiring/Termination
A. All wire connectors and
terminals shall be of the
anti-turn solderless type
and shall be suitable for
copper or aluminum wire
of the sizes indicated. All
connectors must meet
the “Requirements for
Wire Connectors and
Soldering Lugs” as
stated in UL 486B.
B. All loadcenters where
marked shall be suitable
for use with 60°C or
75°C rated wire.

Circuit Breakers
A. Circuit breakers shall
be molded case type.
Circuit breakers shall
have four-rivet
construction (GFI Type—
5 rivets). Multipole circuit
breakers shall be of a
stack pole design to
provide electrical
phase isolation.
B. Each pole of the
circuit breaker will
provide inverse time
delay overload and
instantaneous shortcircuit protection by
means of both thermal
and magnetic sensors.

1
1
1
1
1
1
1
1
1

C. The circuit breaker
calibration shall
not be affected by
environmental changes
in relative humidity.
The thermal bimetal
element shall be welded
to the steel frame and
calibration shall be set
independent of the
molded case by
computer controlled
equipment.
D. All circuit breakers
shall be operated by
a toggle-type handle
and multipole circuit
breakers shall have an
internal common trip
mechanism. The
circuit breakers shall
incorporate trip
mechanisms that are
mechanically trip-free
from the handle. The
handle position shall
provide visual trip
indication.

1
1
1
1
1
1
1
1
1
1
1
1
1

E. Contacts shall be of
non-welding silver alloy.
F. All circuit breakers shall
have the trip rating
inscribed on the handle
on each circuit breaker
pole. Also, unique colorcoded cases that indicate
the UL listed 10 kA or
22 kA interrupting
ratings. Breakers shall
be able to be used
as main or branch
disconnect devices.

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

63

1.2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

G. Branch circuit breakers
may also be used in
the 1/2-inch (12.7 mm)
per pole ratings that
include two-pole 1-inch
(25.4 mm) wide modules
and four-pole 2-inch
(50.8 mm) wide
modules. Two-pole
circuit breakers must
incorporate a common
trip mechanism. The
exclusive CTL rejection
tab feature shall be
provided to limit the
number of branch
devices for a loadcenter
to 42, in compliance with
NEC Article 384-15.
H. Circuit breakers shall
be completely enclosed
in a molded case of
thermoset material.
No internal aluminum
parts shall be used. All
internal ferrous parts
shall be plated to
prevent corrosion.
I. All terminals shall be
listed for use with copper
or aluminum conductors.
Terminals shall be of the
box lug or clamp type
design. The terminals
shall meet UL 486B
requirements and shall
be suitable for use with
either 60°C or 75°C wire.
J. The calibrated bimetal
assembly shall be
mechanically isolated
from the load terminal
using a flexible braided
copper shunt wire, such
that movement of the
terminals due to twisting
and overtorquing does
not affect breaker
calibration.

K. Breakers shall be SWD
rated and/or HACR rated
as required.
L. Arc Fault Interrupting
circuit breakers, (AFI),
shall be provided on all
15 and 20A single-phase
120/240 Vac circuits
except those indicated
as remote controlled
breakers. AFI breakers
shall be “Classified for
mitigating the effects of
arcing faults,” or
conforming to UL
Standard 1699 and as
defined by Article 210-12
Section A of the 1999
NEC Code.
Surge Protection Devices
See Section 4 of the
Distribution Products Catalog
for complete details on
surge protection.
Enclosures
A. Loadcenter shall have
NEMA Type 1 general
purpose or NEMA Type
3R rainproof enclosures
as indicated on the
drawings and shall be
surface or combination
flush/surface mounted
except where noted.
B. Boxes shall be made
from galvanized sheet
steel having multiple
knockouts. Rainproof
boxes shall use
galvanized steel or
an approved coating
system which meets or
exceeds standards for
outdoor NEMA Type 3R
enclosures. Boxes shall
be of sufficient size to
provide at least a
minimum code gutter
space on all sides.

C. The deadfront shall
have an easy adjustment
feature for flush
applications.
D. Boxes shall be factory
assembled into a single
rigid structure.
E. Unless otherwise noted
on drawings, hinged
doors covering all circuit
breaker handles shall
be included in all trims.
Trim doors shall not
uncover any live parts
in making the circuit
breaker handles
accessible. If key locks
are required, all locks
shall be keyed alike.
F. Combination trims for
flush and surface panels
shall be flat and shall
overlap the box by at
least 5/8-inch (15.9 mm)
all around. Trims shall
be mounted by a
screwdriver without the
need for special tools.
Finish
A. Trims shall be bonderized
and finished with a light
gray ANSI-61 enamel.
The paint finish shall be
of a type to which field
applied paint will adhere.
Factory Testing
A. The standard factory
tests shall be performed
on the equipment
provided under this
section. All tests shall
be in accordance with
the latest version of UL
and NEMA.

1
1
1
1
1
1
1
64

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Contents

Riser Panel

Description
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenters . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page
43
66
66
67
69
72

1
1
1
1
1
1
1
1
1
1
1

Riser Panel

1

Product Description
Eaton’s Riser Panel is a
loadcenter with an offset
interior to allow riser cables
to pass through the enlarged
gutter. By using lay-in tap
lugs, the contractor is able to
simply strip off a length of the
riser cable’s insulation, and
tap off to the riser panel’s
main lugs. These panels are
used in the construction of
assisted living homes,
dormitories, public housing
complexes and apartments.

Eaton offers three 125A
and one 200A main lug riser
panels, a 12/24 and a 20/24,
20/30 and 30/40. The panels
are convertible to main
breaker by adding the
appropriate breaker and a
BREQS125 hold-down kit.
Additionally, the 12/24 is
offered in a bulk-packed
version. The bulk-packed
product must be ordered in
multiples of 16, and consists
of a pallet with uncartoned
loadcenters on the bottom,
and cartoned trims on top.
The entire pallet is shrinkwrapped for protection. By
supplying the loadcenter
without a carton, the
contractor is able to save
the unpacking time as well as
saving on the scrap cardboard
on the site.

For applications higher than
125A, or the circuits provided
by the panels above, we
offer the BRGUTTER. This
is essentially a junction box
that mounts next to, and
assembles to standard BR
or CH loadcenters. There
is a matching concentric
knockout that allows the
tapped cables to pass
through from the BRGUTTER
to the loadcenter. The trims
of the loadcenter and the
BRGUTTER are designed
to allow the two boxes to
bolt to one another in a flush
application. There is no
need to allow for the trim
overhang.

1
1
1
1
1
1
1
1
1

Also offered is the GTAP250,
which is a set of three
lay-in, insulated tap lugs.
The maximum wire size for
the GTAP250 is 250 kcmil.
GTAP250 can be used with
either the riser panels or the
BRGUTTER.

1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

65

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Product Selection
BR1224L125RIS

Riser Panel

1

Main Ampere
Rating

1
1
1
1

Maximum Number
1-Inch (25.4 mm)

125

12

24

Indoor

C4

#6–2/0

BR1224L125RIS

125

12

24

Indoor

C4

#6–2/0

BR1224L125RISBP 

125

20

24

Indoor

C4

#6–2/0

BR2024L125RIS

125

20

24

Indoor

C4

#6–2/0

BR2024L125RISBP 

125

20

30

Indoor

C2

#6–2/0

BR2030L125RIS

200

30

40

Indoor

D1

#1–300

BR3040L200RIS

1

For riser panels not shown, contact the Flex Center at
1-800-330-6479 for both CH and BR riser panels.

1

Catalog
Number

Circuits

Accessories

BRGUTTER (Shown
with Loadcenter)

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Space

1
1

Box
Size

Enclosure
Type

Riser Panel Accessories
Catalog Number
BRGUTTER 
GTAP250

1
1
1

Notes
 Bulk-packaged loadcenter without carton. Must be ordered in
multiples of 16.
 Refer to Page 85 for dimensions. BRGUTTER is box size C2.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
66

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Contents

BRRETRO

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenters . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

43
65
68
69
72

1
1
1
1
1
1
1
1
1
1
1

Type BR Retrofit Interior Kits
Product Description
Replacing existing
loadcenters and panelboards
can be a time consuming and
expensive job. BR retrofit kits
can be the solution to save
time and money. The kit
consists of a standard trim to
fit the interior, a picture frame
trim to fit the existing box,
and a field adjustable interior
assembly that includes
neutral and ground bars as
well. These are especially
applicable when the existing
box is flush mounted in
drywall, plaster or block wall.
The existing box, and many
times existing wiring, can
remain. Interiors are UL
recognized under UL 67,
Panelboard standard.

Features
Detailed Product Guide
All standard retrofit kits are
suitable for a range of
existing box sizes:
●

●

●

Box width ranging from
14.50 to 22.00 inches
(368.3 to 558.8 mm)
Box depth ranging from
4.00 inches (101.6 mm)
for BR
Box height ranging from
21.00 to 45.00 inches
(533.4 to 1143.0 mm)

For box dimensions outside
of these ranges, contact
the Lincoln Flex Center at
800-330-6479. Be sure to
provide the existing incoming
line wire size.

1

Product Selection
To select the retrofit kit:
1. From the existing box
size determine which
retrofit groups are
suitable (may be more
than one).
2. Use type of interior,
number of phases, and
type of main to find the
selection chart.
3. Select part number from
chart (if main breaker,
replace XXX with specific
amp rating).

4. Note that the overlap of
the existing wall is the
retro cover size minus
the existing box size. If
specific measurements
are needed, communicate
that you need a custom
trim size.
5. Contact the Lincoln Flex
Center at 800-330-6479
for pricing, lead-times,
and order entry
instructions.

1
1
1

1

Existing Box Height Determines Retro Size Group

1
1

Retro Size D
Retro Size C

1

Retro Size B

1

Retro Size A
29" 30"

1

1

Retro Size Groups

21"

1

1

Retro Size E

Quick-ProSM
All you need to
know to save
time and make
more money.
Specified on certain Eaton
products, the Quick-Pro
symbol allows for immediate
recognition of products
that are designed for
straightforward installation.
When you see Quick-Pro,
you know you can install
quickly—sometimes up to
50% less than the usual
installation time—and move
onto your next job.

1

34" 36" 37"

41"

45"

54"

1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

67

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Dimensions
Approximate Dimensions in Inches (mm)

1
1

Type BR Interior—With Main Breaker
Main Breaker Rating

Existing Box Height

1

Amperes

kAIC

Minimum

Maximum

10

21.00 (533.4)

30.00 (762.0)

1
1
1

Wire
Size

Number
of Circuits

Part
Number

Retro
Size Group

#4–2/0

20

RABR20BXXX 

Retro Cover Size 
Height

Width

A

33.00 (838.2)

24.00 (609.6)

B

40.00 (1016.0)

24.00 (609.6)

Single-Phase
60–125

22
60–125

10

RABR20HXXX 

#4–2/0
29.00 (736.6)

36.00 (914.4)

22

#4–1/0

30

RBBR30BCXXX 
RBBR30HCXXX 

#4–1/0

100–200

25

30.50 (774.7)
36.00 (914.4)

#2–250 kcmil
#2–300 kcmil

20

RBBR20HXXX 

1

29.00 (736.6)
31.00 (787.4)

100–225

25

35.50 (901.7)
41.00 (1041.4)

#2–250 kcmil
#2–300 kcmil

30

RCBR30HXXX 

C

43.00 (1092.2)

24.00 (609.6)

1

34.00 (863.6)
36.00 (914.4)

100–225

25

37.00 (939.8)
39.00 (990.6)
41.00 (1041.4)

38.50 (977.9)
40.50 (1028.7)
45.00 (1143.0)

#2–4/0
#2–250 kcmil
#2–300 kcmil

40

RDBR40HXXX 

D

47.00 (1193.8)

24.00 (609.6)

10

21.00 (533.4)

30.00 (762.0)

#4–2/0

12

RABR12B3XXX 

A

33.00 (838.2)

24.00 (609.6)

B

40.00 (1016.0)

24.00 (609.6)

RDBR30H3XXX 

D

47.00 (1193.8)

24.00 (609.6)

REBR42B3XXX 

E

56.00 (1422.4)

24.00 (609.6)

Retro
Size Group

Retro Cover Size 
Height
Width

1
Three-Phase

1
1

60–100

22
60–100

1

29.00 (736.6)

36.00 (914.4)

22
100–200

1
1

10

100–225

1

RABR12H3XXX 

#4–2/0
#4–1/0

30

RBBR30H3XXX 

#4–1/0

10

37.00 (939.8)

45.00 (1143.0)

2/0–300 kcmil

100

37.00 (939.8)
39.00 (990.6)

38.50 (977.9)
45.00 (1143.0)

2/0–250 kcmil
2/0–300 kcmil

10

34.00 (863.6)

35.50 (901.7)

2/0–250 kcmil

100

36.00 (914.4)

41.00 (1041.4)

2/0–300 kcmil

RBBR30BXXX 

30

42

RDBR30B3XXX 

REBR42H3XXX 

1

Type BR Interior—Main Lug Only

1

Maximum Bus
Ampere Rating

1

Single-Phase
125

21.00 (533.4)

30.00 (762.0)

#14–2/0

24

RABR20L125

A

33.00 (838.2)

24.00 (609.6)

1

200

29.00 (736.6)
32.00 (812.9)

31.50 (800.1)
36.00 (914.4)

#1–250 kcmil
#1–300 kcmil

30

RBBR30L200

B

40.00 (1016.0)

24.00 (609.6)

1

200

34.00 (863.6)
37.00 (939.8)

36.50 (927.1)
41.00 (1041.4)

#1–250 kcmil
#1–300 kcmil

40

RCBR40L200

B

43.00 (1092.2)

24.00 (609.6)

1

200

37.00 (939.8)
39.00 (990.6)

38.50 (977.9)
45.00 (1143.0)

#1–250 kcmil
#1–300 kcmil

42

RDBR42L225

B

47.00 (1193.8)

24.00 (609.6)

1

Three-Phase
125

21.00 (533.4)

30.00 (762.0)

#8–2/0

24

RABR12L3125

A

33.00 (838.2)

24.00 (609.6)

1

100

29.00 (736.6)

36.00 (914.4)

#8–2/0

24

RBBR30L3100

B

40.00 (1016.0)

24.00 (609.6)

150

29.00 (736.6)

36.00 (914.4)

#4–4/0

24

RBBR24L3150

1

200

34.00 (863.6)
36.00 (914.4)

35.50 (901.7)
41.00 (1041.4)

#4–250 kcmil
#4–300 kcmil

30

RCBR30L3200

C

43.00 (1092.2)

24.00 (609.6)

1

225

37.00 (939.8)
39.00 (990.6)

38.50 (977.9)
45.00 (1143.0)

#4–250 kcmil
#4–300 kcmil

42

RDBR42L3225

D

47.00 (1193.8)

24.00 (609.6)

1

225

45.00 (1143.0)

54.00 (1371.6)

#4–300 kcmil

42

REBR42L3225

E

56.00 (1422.4)

24.00 (609.6)

1

Notes
 Specific cover sizes are available. Be sure to specify the custom cover option and provide exact dimensions required.
 XXX is for Main Breaker specific ampere rating.

1

Existing Box Height
Minimum
Maximum

Wire
Size

Number
of Circuits

Part
Number

1
68

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Contents

BR Renovation Loadcenters

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenters
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories. . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

43
65
67
69
70
72

1
1
1
1
1
1
1
1
1
1

Type BR Renovation Loadcenters

●

Product Description
●

●

●

●

●

Available in 10, 20, 30
and 40 circuit main
breaker styles
Designed to replace
existing loadcenters
and fuse boxes
Type BR loadcenter
packaged with circuit
breakers
Factory-installed 5-circuit
terminal block(s)
Twin-stacked neutral
design

1

Features, Benefits and Functions

Quick-Pro
All you need to
know to save
time and make
more money.
Specified on certain Eaton
products, the Quick-Pro
symbol allows for immediate
recognition of products
that are designed for
straightforward installation.
When you see Quick-Pro,
you know you can install
quickly—sometimes up to
50% less than the usual
installation time—and move
onto your next job.
SM

●

Factory-installed terminal
block(s) allows installer to
terminate existing short
wires without using wire
nuts or junction boxes
Twin-stacked neutrals are
mounted up high in the
loadcenter, which allows
for all neutral and ground
wires to be terminated in
the top half of the
loadcenter

●

●

●

Specifically designed for
the service contractor—
this is the ONLY renovation
line in the industry
Single-pole and two-pole
breakers included
10-year warranty on
loadcenter and breakers

1
1
1
1
1
1
1
1
1

Product Selection
BR2020B100RN

1

1

BR Value Packs 
Main
Breaker
Type

Description

BR
10 kAIC

Single-phase 100A 10k main breaker 10/20
circuit surface-mount box is 11.75" wide x 13" tall

BWH
25 kAIC

Wire Size
Range

Number of
5-Circuit
Terminal Blocks

Single-Pole
Breakers

Two-Pole
Breakers

Catalog
Number

#6–1/0

0

(2) BR115

(1) BR230

BR1020B100S11RN

1

Single-phase 100A 10k main breaker 10/20
circuit flush-mount box is 11.75" wide x 13" tall

0

(2) BR115

(1) BR230

BR1020B100F11RN

1

Single-phase 100A
10 kAIC main breaker 20/20 circuit

1

(5) BR120

(1) BR230

BR2020B100RN

1

2

(5) BR115
(5) BR120

(1) BR230
(1) BR250

BR3040B200RN

1

2

(6) BR115
(6) BR120

(1) BR230
(1) BR250

BR4040B200RN

1

Single-phase 200A
25 kAIC main breaker 30/40 circuit
Single-phase 200A
25 kAIC main breaker 40/40 circuit

#2–300
kcmil

1

1

Note
 Indoor enclosure type.

1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

69

1.2
1
1
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Options and Accessories
Mechanical Interlock Cover
Covers mechanically interlock two breakers—Type BW
or BWH main breaker with a Type BR branch breaker.
BR4040B200

Mechanical Interlock Cover
Fits Loadcenter
Catalog Numbers

Mechanical Interlock Panel Cover
Catalog Number
Flush

BR816B200RF

BR3RDF5M

BR2040B200R

BR3RDF11M

BR3040B200R

BR3RDF12M

BR4040B200R

BR3RDF13M

1

BR2040B200

BRCOV20D1FM

BR3040B200

BRCOV30G1FM

1

BR4040B200

BRCOV40L1FM

1
1
1

1
1

BRSF125

1
1

Field Installation Kits and Parts
Number
of Poles

Ampere
Rating

Number of 1-Inch (25.4 mm)
Spaces Needed

Wire Size Range
Cu/Al 60°C or 75°C

Ordering
Quantity 

Catalog
Number

Main and Sub-Feed Lug Blocks
2
3BRS225

1

3

1

125

2

#8–2/0

1

BRSF125

150

2

#8–2/0

1

BRSF150 

225

4

#2–300 kcmil

1

BRS225

150

3

#8–2/0

1

3BRSF150 

225

6

#2–300 kcmil

1

3BRS225

Main Lugs

1

Two-pole, 200A stud mounted (includes deadfront filler plate)

#1–300 kcmil

1

BRL200

Neutral/ground lug
Add-on neutral or ground lug

#2/0 maximum

1

NL20

#3/0 maximum

1

NL30

300 kcmil maximum

1

NL300

1-inch (25.4 mm) circuit breaker space

25

BRFP

BW main circuit breaker space (with hardware)

1

BWFP

Door lock —12–42 circuits, and 100–225A

1

TDL

1

Door lock—4–8 circuits, 125A

1

CH9FL

ANSI-61 light gray touchup paint for current loadcenters

1

SPC61

1

Isolated neutral assembly (computer circuits)

1

BINA

Circuit directory—adhesive backed

10

TCD

Cover screws

25

LCCS

Cover replacement latch (gray) 14-5/16 (363.5 mm) wide loadcenters only

1

BRRL

Circuit marking strip (next to breaker)

10

BRMS

1

Circuit identification label (preprinted breaker labels)

25

CHBL

Series rated caution label

25

SRL

1

Bonding strip with screw

1

BSSUSE

1

Notes
 Must be purchased in multiples of ordering quantities indicated.
 #8–2/0 wire size range is 75°C rated only.

1

BRL200

1
Filler Plates

1
TDL

1

1
1

1
1
1
70

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

DS300H2

1.2

Field Installation Rainproof Conduit Hubs
Conduit Size
Inches (mm)

Ordering
Quantity 

Catalog
Number

0.75 (19.1)

1

DS075H1

1.00 (25.4)

1

DS100H1

1.25 (31.8)

1

DS125H1

1.50 (38.1)

1

DS150H1

2.00 (50.8)

1

DS200H1

Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosures except for 2.00 (50.8)
the following 200A loadcenters: BR48B200RF. Also for use with 400 and 600A loadcenters and New York City
2.50 (63.5)
loadcenters manufactured after November 1, 2005
3.00 (76.2)

1

DS200H2

1

DS250H2

1

DS300H2

Type H conduit hubs for loadcenters PL0724R and S3100RN

0.75 (19.1)

1

RH75P

1.00 (25.4)

1

RH100P

1.25 (31.8)

1

RH125P

1.50 (38.1)

1

RH150P

Adapter kit—Allows Installing a Group 1 hub on devices arranged for Group 2 hubs

—

1

DS900AP

Group 1 small blank hub plate with bump

—

1

DS900CP1

Group 2 Large blank hub plate with bump

—

1

DS900CP2

Description
Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures and the
following 150 and 200A panels: BR48B200RF

1
1
1
1
1
1
1
1
1
1
1

GBK14

Ground Bar Kits

1
Ordering
Quantity 

Catalog
Number

 2.54 (64.5)

1

GBK5 

 3.59 (91.2)

1

GBK520 

 4.29 (109.0)

1

GBK10 

 5.34 (135.6)

1

GBK1020 

4.61 (117.1)

1

GBK13 

 5.69 (144.5)

1

GBK14 

 6.74 (171.2)

1

GBK1420 

 8.14 (206.8)

1

GBK21 

 9.19 (233.4)

1

GBK2120 

5.78 (146.8)

1

BRGBK39512 

1

GB4NM 

Description
(See Legend)

Length
Inches (mm)



































BRGBK39512

 1.84 (46.7)

1
1
1
1
1
1
1
1

Ground Bar Legend

 (3) #14–10 Cu/Al or (1) #14–4 Cu/Al
 (1) #6–2/0 Cu/Al
(1) #14–1/0 Cu/Al or (3) #14–10 Cu/Al
(1) #14–6 Cu/Al or (2) #14–12 Cu/Al
 Mounting Hole



1
1
1

Notes
 Must be purchased in multiples of ordering quantities indicated.
 Distance between mounting holes is 1.75 inches (44.5 mm).
 For single- and three-phase 400 and 600A applications.
 Distance between mounting holes is 2.34 inches (59.5 mm).
 For non-metallic enclosures. Snaps into molded base.

1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

71

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Contents

BR Circuit Breakers

Description

1

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenters . . . . . . . . . . . . . . . . . . . .
Circuit Breakers
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breaker Accessories . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1

43
65
67
69
73
81
83
85

1
1
1
1
1

Circuit Breakers

1

Product Description

1

Plug-On Branch Feeder Type
Arc Fault Circuit Breakers,
Type BR—10 kAIC, 120 Vac
and 120/240 Vac
A branch feeder type arc fault
circuit interrupter is a device
intended to mitigate high
current arcing faults in the
complete circuit, including
connected cords. High
current arcing faults can
occur from line to neutral or
line to ground. These arcing
faults are in parallel with the
load and produce the most
energy of all arcing faults.

1
1
1
1
1
1
1
1
1
1

The branch feeder type AFCI
is required in the 1999 and
2002 National Electrical Code.
The Combination Type AFCI
is required in the 2005 and
2008 National Electrical Code.

1
1
1
1

Plug-On Combination Type
Arc Fault Circuit Breakers,
Type BR—10 kAIC, 120 Vac
and 120/240 Vac
A combination type arc
fault circuit interrupter is a
device that includes all of
the protection offered by the
branch feeder AFCI (mitigation
of high current arcing faults in
the complete circuit, including
connected cords). In addition
it provides direct detection of
persistent low current arcing
faults down to 5 amps with
associated mitigation of
fire hazards in the cords
connected to the outlets. High
current arcing faults can occur
from line to neutral or line to
ground. These arcing faults
are in parallel with the load
and produce the most energy
of all arcing faults. The current
level of low current arcing
faults is limited by the load.

Plug-On Ground Fault Circuit
Breakers, Type GFCB and
GFEP—10/22 kAIC, 120 Vac
and 120/240 Vac
Ground Fault
Application Notes
Single-pole GFCBs are
designed for use in twowire, 120 Vac circuits. See
Page 83 for a typical wiring
configuration.
Two-pole GFCBs are
designed for use in threewire, 120/240 Vac circuits,
120 Vac multiwire circuits
employing common, neutral
and two-wire, 240 Vac
circuits obtained from a
120/240 Vac source.
Page 83 shows typical wiring
configurations for a 120/240
Vac multiwire circuits, and a
240 Vac, two-wire circuit.
Note the “panel neutral”
conductor connects to the
neutral bar, even though the
neutral is not included in the
load circuit. This connection
is necessary to supply a
120 Vac power source to the
ground fault sensing circuit.

1
1
1
72

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

The figures are shown with
a 120/240 Vac, single-phase,
three-wire power source,
but are also applicable to a
120/208 Vac, three-phase,
four-wire power supply.
For all figures, the electrical
operation of the GFCB is
not affected by the
equipment ground.
Non-CTL Plug-On Replacement
—Circuit Breakers, Type BRD—
10 kAIC, 120/240 Vac
Non-CTL 10 kAIC
for Replacement
Purposes Only
For replacement in
enclosures manufactured
prior to 1968 with unnotched
stabs. Circuit breakers do
not have rejection tab.

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Product Selection

1

Plug-On Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac
BR120

BR320

BRH2100

1

22 kAIC
Catalog
Number

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
10 kAIC
22 kAIC
Catalog
Catalog
Number
Number

—

BR210

—

—

Single-Pole 120/240 Vac
Requires One 1-Inch (25.4 mm) Space

BR215

1

Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC

1

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

10 per Shelf Carton
10 kAIC
Catalog
Number

10

#14–4

BR110

15

#14–4

BR115 

BRH115

BR215 

BRH215

—

20

#14–4

BR120



BRH120

BR220 

BRH220

—

25

#14–4

BR125

BRH125

BR225 

BRH225

—

30

#14–4

BR130

BRH130

BR230 

BRH230

—

35

#14–4

BR135

BRH135

BR235 

BRH235

—

42 kAIC
Catalog
Number

40

#14–4

BR140

BRH140

BR240 

BRH240 

—

45

#14–4

—

BRH145

BR245 

BRH245

—

50

#14–4

BR150

BRH150

BR250 

BRH250 

—

55

#14–3

BR150

BRH155

BR255

BRH255

—

60

#8–1/0

BR160

BRH160

BR260

BRH260

BRHH260

70

#8–1/0

BR170

BRH170

BR270

BRH270

BRHH270

80

#8–1/0

—

—

BR280

BRH280

BRHH280

90

#8–1/0

—

—

BR290

BRH290

BRHH290

100

#8–1/0

—

—

BR2100

BRH2100

BRHH2100

110

#8–1/0

—

—

BR2110

BRH2110

BRHH2110

125

#4–2/0

—

—

BR2125

BRH2125

BRHH2125

150

#4–2/0

—

—

BR2150 

—

—

1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number.
 Switching duty rated.
 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits.
 For use as a branch circuit breaker in 400 and 600 ampere panels only.
All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix.

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

73

1.2
1

BR Breakers

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Type BR Breakers, 1-Inch (25.4 mm) per Pole 240 Vac, 10, 22 and 42 kAIC

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

Three-Pole 240 Vac
Common Trip Requires Three
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
10 kAIC
Catalog Number

10

#14–4

BR310

1
1
1

22 kAIC
Catalog Number
—



BRH315

15

#14–4

BR315

20

#14–4

BR320 

BRH320

1

25

#14–4

BR325

BRH325

30

#14–4

BR330

BRH330

1

35

#14–4

BR335

BRH335

40

#14–4

BR340

BRH340

45

#14–4

BR345

BRH345

1

50

#14–4

BR350

BRH350

55

#14–3

BR355

BRH355

1

60

#4–1/0

BR360

BRH360

70

#4–1/0

BR370

BRH370

80

#4–1/0

BR380

BRH380

90

#4–1/0

BR390

BRH390

100

#4–1/0

BR3100

BRH3100

1

1

1
1
1
1
1

Plug-On Branch Feeder Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac
Type BR AFCI
Circuit Breaker

Type BR, 1-Inch (25.4 mm) Wide FIRE-GUARD AFCI Circuit Breakers
Poles

1

Single-pole
10 kAIC

1

Single-pole
22 kAIC

1

Two-pole
10 kAIC 

1
1

Ampere
Rating

Configuration

Catalog
Number

15

AFCI

BR115AF 

20

AFCI

BR120AF 

15

AFCI

BRH115AF

20

AFCI

BRH120AF

15

AFCI Common Trip

BRL215AF

20

AFCI Common Trip

BRL220AF

Notes
 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number.
 Clamshell packaging available with CS modification code on the end of catalog number.
 Common trip refers to two-pole 240V load application sourced by 120/240 Vac (see Page 83).
 Independent trip refers to two-pole multi-wire, home run or shared neutral circuits (see Pages 83 and 83).

1
1

All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix.

1
1
1
1
1
1
1
1
74

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Plug-On Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac

1

Type BR, 1-Inch (25.4 mm) wide FIRE-GUARD Combination Type AFCI
Circuit Breakers
Poles
Single-pole
10 kAIC

Ampere
Rating

Configuration

Catalog
Number

15

AFCI

BR115CAF 

1
1
1

BRC115CAF
20

AFCI

BR120CAF 

1

BRC120CAF
Single-pole
15 kAIC
Two-pole
10 kAIC

15

AFCI

BRLH115CAF 

22

AFCI

BRLH120CAF 

15

AFCI

BR215CAF

20

AFCI

BR220CAF

1
1
1
1

Plug-On Ground Fault Circuit Breakers, Type GFCB and GFEP—10/22 kAIC, 120 Vac and 120/240 Vac
Type GFCB Single-Pole

Single-Pole 120 Vac
Requires One
1-Inch (25.4 mm) Space

Type GFCB Two-Pole

1

Type GFCB Ground Fault Circuit Breakers—5 Milliampere—
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10 kAIC

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

1 per Shelf Carton
Catalog Number 

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
1 per Shelf Carton
Catalog Number

15

#14–4

GFCB115

GFCB215

20

#14–4

GFCB120

GFCB220

25

#14–4

GFCB125

GFCB225

30

#14–4

GFCB130

GFCB230

40

#14–4

GFCB140

GFCB240

50

#14–4

—

GFCB250 

60

#14–6

—

GFCB260

1
1
1
1
1
1
1
1

Notes
 Clamshell packaging available with CS modification code on the end of catalog number.
 Available with bell alarm or auxiliary switch. See circuit breaker accessories on Page 81.
 For use with copper wire only.

1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

75

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Type GFCBH Ground Fault Breakers—5 Milliampere—
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 22 kAIC

1
1
1

Single-Pole 120 Vac
Requires One
1-Inch (25.4 mm) Space

1
1
1
1

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

1 per Shelf Carton
Catalog Number

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
1 per Shelf Carton
Catalog Number

15

#14–4

GFCBH115

GFCBH215

20

#14–4

GFCBH120

GFCBH220

25

#14–4

GFCBH125

GFCBH225

30

#14–4

GFCBH130

GFCBH230

1
Type GFEP Ground Fault Equipment Protectors—30 Milliampere—
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10 kAIC

1
1
1

Single-Pole 120 Vac
Requires One
1-Inch (25.4 mm) Space
Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

1 per Shelf Carton
Catalog Number

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Space
1 per Shelf Carton
Catalog Number

15

#14–4

GFEP115

GFEP215

1

20

#14–4

GFEP120

GFEP220

25

#14–4

GFEP125

GFEP225

1

30

#14–4

GFEP130

GFEP230

40

#14–4

—

GFEP240

50

#14–4

—

GFEP250 

1
1

1
1

Note
 For use with copper wire only.

1
1
1
1
1
1
1
1
1
1
1
1
1
76

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

CTL Plug-On Circuit Breakers, Type BD Duplex, BQ and BQC Quadplex—10 kAIC, 120/240 Vac
BD2020

1

Class CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—All Circuit Breakers Have Rejection Tab Feature
Type BD Duplex
(UL Type BRD)

Type BQ Quadplex Independent Trip
(UL Type BRD)

Vac

Single-Pole 
Requires One 1-Inch
(25.4 mm) Space
10 per Shelf Carton
BQ2302115
Ampere
Rating

BQ230230

Catalog
Number

1

120/240 Vac

120/240 Vac
120/240 Vac

120 Vac

1

Type BQ Quadplex Independent Trip
(UL Type BRD)

Two-Pole  and Single-Pole 
Requires Two 1-Inch
(25.4 mm) Spaces
5 per Shelf Carton
Wire Size
Range
Cu/Al
65°C or 75°C

120 Vac
120/240 Vac
120 Vac
Ampere Rating
Outer Left
Center Two-Pole Outer Right Catalog
Single-Pole Independent Trip Single-Pole Number

1

Two-Pole
Requires Two 1-Inch
(25.4 mm) Spaces
5 per Shelf Carton
120/240 Vac
Ampere Rating
Outer Two-Pole Center Two-Pole Catalog
Independent Trip Independent Trip Number

10–10

BD1010

#14–4

15

20

15

BQ2202115 15

15

BQ215215

15–15

BD1515

#14–4

20

20

20

BQ2202120 15

20

BQ215220

15–20

BD1520

#14–4

15

30

15

BQ2302115 15

30

BQ215230

15–30

BD1530

#14–4

20

30

20

BQ2302120 15

40

BQ215240

20–15

BD2015

#14–4

15

40

15

BQ2402115 15

50

BQ215250

20–20

BD2020

#14–4

20

40

20

BQ2402120 20

20

BQ220220

20–30

BD2030

#14–4

15

50

15

BQ2502115 20

30

BQ220230

25–25

BD2525

#14–4

20

50

20

BQ2502120 20

40

BQ220240

30–15

BD3015

#14–4

—

—

—

—

50

BQ220250

20

30–20

BD3020

#14–4

—

—

—

—

25

25

BQ225225

30–30

BD3030

#14–4

—

—

—

—

30

30

BQ230230

30–40

BD3040

#14–4

—

—

—

—

30

40

BQ230240

30–50

BD3050

#14–4

—

—

—

—

30

50

BQ230250

50–30

BD5030

#14–4

—

—

—

—

40

40

BQ240240

50–50

BD5050

#14–4

—

—

—

—

40

50

BQ240250

—

—

—

—

—

—

—

50

50

BQ250250

1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
 All Type BD duplex and BQ quadplex circuit breakers carry listing for HACR applications.
 All 15 and 20A single poles are switch-duty rated.

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

77

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Non-CTL Plug-On Replacement—Circuit Breakers, Type BRD—10 kAIC, 120/240 Vac
BR2020

Class Non-CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—Breakers Do Not Have Rejection Tab Feature
Type BR Duplex

1

Type BRD Quadplex Common Trip
Center and Outer Poles

Type Brand BRD Quadplex Independent Trip
120/240 Vac

120/240 Vac
120/240 Vac

1

Single-Pole Requires One
1-Inch (25.4 mm) Space
10 per Shelf Carton

1

120 Vac

1
1
1
1
1
1

120/240 Vac

Vac

Vac

Two-Pole Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
120/240 Vac
Ampere Rating
Outer Two-Pole
Independent Trip

Center Two-Pole
Independent Trip

Catalog
Number

Two-Pole Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
120/240 Vac
Ampere Rating
Outer Two-Pole Center Two-Pole
Common Trip
Common Trip

120/240 Vac

Ampere
Rating

Catalog
Number

Wire Size
Range
Cu/Al
65°C or 75°C

15–15

BR1515

#14–4

15

15

BR415

15

15

BRDC215215

15–20

BR1520

#14–4

20

20

BR420

30

30

BRDC230230

20–15

BR2015

#14–4

30

30

BR430

30

40

BRDC230240

20–20

BR2020

#14–4

20

30

BRD220230

30

50

BRDC230250

30–30

BR3030

#14–4

30

40

BRD230240

—

—

—

30–50

BR3050

#14–4

30

50

BRD230250

—

—

—

Catalog
Number

CTL and Non-CTL Breakers

1
Notched
Bus Stab

1
1

Unnotched
Bus Stab

1
1

Type BR or Type BD Duplex, (CTL),
Type BQ and
BQC Quadplex

CTL Circuit
Limiting
Feature

Type BD
Duplex
Rejection
Tab

Type BR

Notched
Stab

Non-CTL
Non-Circuit
Limiting

Type BR

1
1

Note
Type BD Duplex, BQ and BQC Quadplex (CTL) circuit breakers conform to Section 384-15 of the latest National Electrical Code. Install breaker only in panel positions that
have notched bus stabs.

1
1
1
1
1
1
1
1
1
1
1
1
78

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Common Trip Quadplex Breakers
BQC2302115

1

Class CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—All Circuit Breakers Have Rejection Tab Feature
Type BQC Quadplex Common Trip Center Poles
(UL Type BRD)

1

Type BQC Quadplex Common Trip Center and Outer Poles
(UL Type BRD)

1

120/240 Vac
Vac

BQC2302115

Two-Pole  and Single-Pole 
Requires Two 1-Inch (25.4 mm) Spaces
5 per Shelf Carton
120 Vac
120/240 Vac
120 Vac
Ampere Rating
Outer Left
Center Two-Pole
Outer Right
Single-Pole
Common Trip
Single-Pole

Catalog
Number

15

20

15

BQC2202115

15

25

15

BQC2252115

#14–4

15

30

15

BQC2302115

#14–4

1

Wire Size Range
Cu/Al 65°C
or 75°C

Two-Pole 
Requires Two 1-Inch (25.4 mm) Spaces
5 per Shelf Carton
120/240 Vac
Ampere Rating
Outer Two-Pole
Center Two-Pole
Common Trip
Common Trip

Catalog
Number

#14–4

15

15

BQC215215

15

20

BQC215220

15

30

BQC215230

1

15

40

15

BQC2402115

#14–4

20

15

BQC220215

15

50

15

BQC2502115

#14–4

20

20

BQC220220

—

—

—

—

#14–4

20

30

BQC220230

—

—

—

—

#14–4

20

40

BQC220240

—

—

—

—

#14–4

20

50

BQC220250

20

15

20

BQC2152120

#14–4

25

25

BQC225225

20

20

20

BQC2202120

#14–4

25

30

BQC225230

20

25

20

BQC2252120

#14–4

30

15

BQC230215

20

30

20

BQC2302120

#14–4

30

30

BQC230230

20

40

20

BQC2402120

#14–4

30

40

BQC230240

20

50

20

BQC2502120

#14–4

30

50

BQC230250

30

50

20

BQC2502030

#14–4

40

30

BQC240230

—

—

—

—

#14–4

40

40

BQC240240

—

—

—

—

#14–4

40

50

BQC240250

—

—

—

—

#14–4

50

20

BQC250220

—

—

—

—

#14–4

50

50

BQC250250

1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
 All Type BQC quadplex circuit breakers carry listing for HACR applications.
 All 15 and 20 ampere single poles are switch-duty rated.

1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

79

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Plug-On Circuit Breakers, Types BJ and BJH—10/22 kAIC, 120/240 Vac and 240 Vac
For Use in Single-Phase and Three-Phase Loadcenters—150 Amperes and Above
Type BJ

Types BJ and BJH Breakers, 1-Inch (25.4 mm) per Pole, 120/240 or 240 Vac, 10, 22 kAIC

1
1

Wire Size Range
Cu/Al 60°C or 75°C

Three-Pole 240 Vac
Common Trip Requires Six
1-Inch (25.4 mm) Spaces 
5 per Shelf Carton
10 kAIC
22 kAIC
Catalog Number
Catalog Number

1

Ampere
Rating

Two-Pole 120/240 Vac
Common Trip Requires Four
1-Inch (25.4 mm) Spaces 
10 per Shelf Carton
10 kAIC
22 kAIC
Catalog Number
Catalog Number

1

125

BJ2125

BJH2125

#2–300 kcmil

BJ3125

BJH3125

150

BJ2150

BJH2150

#2–300 kcmil

BJ3150

BJH3150

1

175

BJ2175

BJH2175

#2–300 kcmil

BJ3175

BJH3175

200

BJ2200

BJH2200

#2–300 kcmil

BJ3200

BJH3200

225

BJ2225

BJH2225

#2–300 kcmil

BJ3225

BJH3225

1

1
1
1
1

Plug-On Special Application Circuit Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 Vac
BRWH215
Water Heater Breaker

Special Application Circuit Breakers, 1-Inch (25.4 mm) per Pole
Water Heater Breakers

Switching Neutral Breakers

240V Breakers

Non-Automatic Molded Case Switches

Two-Pole 240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

Two-Pole 240 Vac
Requires Two
1-Inch (25.4 mm) Spaces

LINE

1

OUT
IN

LOAD
NEUTRAL

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

Two-Pole 120 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

With Isolated Line Terminals
for Separately Metered
Water Heaters
5 per Shelf Carton
10 kAIC
Ampere
Catalog
Rating
Number

With Switching Neutral Pole
for Gasoline Pump Applications
5 per Shelf Carton
10 kAIC
Ampere
Catalog
Rating
Number

Wire
Size
Range
Cu/Al
60°C or
75°C

Where Voltage to
Ground is 240 Vac
5 per Shelf Carton
10 kAIC
Ampere
Catalog
Rating
Number

For Use as Disconnect Contains No
Magnetic or Thermal Trip Properties
5 per Shelf Carton
5 kAIC
Ampere
Catalog
Rating
Number

15

BRWH215

15

BRSN215

#14–4

10

BR210H

—

—

1

20

BRWH220

20

BRSN220

#14–4

15

BR215H

—

—

30

BRWH230

25

BRSN225

#14–4

20

BR220H

—

—

1

—

—

30

BRSN230

#14–4

25

BR225H

—

—

—

—

—

—

#14–4

30

BR230H

—

—

—

—

—

—

#14–4

35

BR235H

—

—

—

—

—

—

#14–4

40

BR240H

—

—

—

—

—

—

#14–4

45

BR245H

—

—

1

—

—

—

—

#14–4

50

BR250H

50

BR250NA

—

—

—

—

#14–4

55

BR255H

—

—

1

—

—

—

—

#4–1/0

60

BR260H

60

BR260NA

—

—

—

—

#4–1/0

70

BR270H

—

—

—

—

—

—

#4–1/0

80

BR280H

—

—

1

—

—

—

—

#4–1/0

90

BR290H

—

—

—

—

—

—

#4–1/0

100

BR2100H

100

BR2100NA

1

Notes
 Breaker uses two 1-inch (25.4 mm) pole spaces on left side and two 1-inch (25.4 mm) pole spaces on right side of loadcenter.
 Breaker uses three 1-inch (25.4 mm) pole spaces on left side and three 1-inch (25.4 mm) pole spaces on right side of loadcenter.

1
1
1

BRSN220
Switching Neutral
Breaker

1
1

1
1

1

1

If BJ or BJH breakers are used as a main or a back feed device, a hold-down kit is required. See Page 81.

1
1
80

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Circuit Breaker Accessories
THS1

1

Field Installation Kits and Parts
Catalog
Number

Handle tie bar for physically joining the handles of two adjacent single-pole Type BR circuit breakers (metal cylinder pin type)

10

BHT

1

Handle tie bar for joining two independent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD
duplex circuit breakers

10

THOW

1

THS1

1

Description
Handle Ties 

BHLW2

Handle tie bar for joining two adjacent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD duplex circuit breakers 10
BRQLW

MCBPL (Installed)

Handle Lockoffs



1
10

BRLW

Padlockable device for locking the handle of a single-pole Type BR circuit breaker.(handle mounted) 

10

BRLW1

Padlockable device for locking the handle of a two- and three-pole Type BR circuit breaker (handle mounted) 

10

BRLW2

Padlockable device for locking the handle of a single-pole Type BD Duplex, BQ or BQC Quadplex breaker (handle mounted) 

10

BRDL1

1

Padlockable device for locking the handle of the two center poles and the two outer poles of a two-pole Types BQ and BQC quadplex
circuit breakers (escutcheon mounted) 

10

BRQLW

1

Padlockable device for locking the handle of main circuit breaker Types CC and CHH into the ON or OFF position (screw mounted) 

1

CCPL

1

Mounted) 

1

MCBPL

1

Device used to secure handle in ON or OFF position for single-, two- or three-pole Type BR circuit breakers and single-pole of Type BD
duplex and one independent outside pole of Type BQ or BQC Quadplex circuit breakers (escutcheon mounted) 

10

BHLW

Device used to secure handle in ON or OFF position for single-pole Type BR circuit breakers (handle mounted) 

10

BHLW1

Device used to secure handle in ON or OFF position for two- and three-pole Type BR circuit breakers (handle mounted) 

10

BHLW2

Device used to secure handle in ON or OFF position for single-pole Type GFCB ground fault circuit breakers (handle mounted) 

10

BHGW

Device used to secure handle in ON or OFF position for one independent outside pole of Types BQ and BQC Quadplex or single-pole
Type BD duplex circuit breakers (handle mounted) 

10

HLW1

Hold-down retainer kit for three-pole Type BR circuit breakers in S3100 and 3100R loadcenters only

1

BRHDB

Hold-down screw kit for two-pole Type BR circuit breakers in single-phase MLO loadcenters through 125A

1

BREQS125

Hold-down screw kit for two-pole Type BR circuit breakers in MLO loadcenters 150–225A (single-phase only)

1

BRHDK125

Hold-down screw kit for two-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225A

1

BJHDS

Hold-down screw kit for three-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225A

1

BJHDS3P

Types CC and CHH main breaker lug kit (2) 300 kcmil

1

CCL300

1

Types BW/BWH main breaker lug kit (2) 300 kcmil

1

MCBL300

1

Padlockable device for locking the handle of main breaker Types BW and BWH into the ON or OFF position (escutcheon

BREQS125

1

Padlockable device for locking the handle of single-, two- or three-pole Type BR Circuit Breakers and single-pole of a Type BD Duplex
or one independent outside pole of a Type BQ or BQC Quadplex circuit breakers (escutcheon mounted) 

1
1

BHLW

BRLW2

1

Ordering
Quantity 

1
1
1
1
1

Hold-Down Kits 	

1
1

BRHDK125

1

Main Breaker Lug Kits

Notes
 Must be purchased in multiples of ordering quantities indicated.
 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker.
 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position.
 See table on Page 82 for handle position changeability chart.
 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront.
 Handle mounted: device mounted directly to the handle by the use of a set screw.
 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw.
 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle Lockdogs are not padlockable devices.
	 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384-16(g).

1

1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

81

1.2
1

BRML

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Field Installation Kits and Parts, continued
Ordering
Quantity 

Catalog
Number

10

BRML

10

BRPLOFF

10

BRPLOFF2P

10

BRPLOFF3P

1

10

BJL2P

1

10

BJL3P

10

GHQRLOFF2P

10

GHQRLOFF

10

QCD123PLOFF

Description

1

Mechanical Interlocks

1

Types BR for two-, three- and four-pole breakers

1
1

1
1
1
Shunt Trips, Auxiliary and Alarm Contacts

1

Catalog Number 
Suffix Adder

Description

1

Shunt Trip for Types BW/BWH

1

12 Volts

SR12

24 Volts

SR24

1

120 Volts

SR01

Shunt Trip for Types BR

1

120 Volts

ST

1

Auxiliary Contact for Types BW/BWH
1NO and 1NC

AL1

1

2NO and 2NC

AL2

Alarm Contacts for Types BW/BWH

1

Types BW/BWH

CR1

Alarm Contacts for Type GFCB (Single-Pole)

1
1
1

Alarm contact for GFCB (single-pole)

W1

1NO and 1NC

W2

Handle Position Changeability Chart
To Change Handle Position from ON to OFF, or OFF to ON
You Must...

1
1

Handle Lockoff and
Lockdog Types

1
1
1
1

Remove
Padlock

Remove
Device

Remove
Loadcenter
Deadfront

Lockoff escutcheon mounted

Remove

—

—

Lockoff handle mounted

Remove

Remove

—

Lockoff screw mounted

Remove

—

—

Lockdog escutcheon mounted

N/A

Remove

Remove

Lockdog handle mounted

N/A

Remove

—

Notes
 Must be purchased in multiples of ordering quantities indicated.
 Add suffix indicated to end of breaker catalog number.

1
1
1
82

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Wiring Diagrams
Single-Pole 120V Load Application Sourced by 120/240 Vac

Two-Pole Shared Neutral with Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
1
1

Line B

Line B

1

Line A

1

Two-Pole

Single-Pole
Neutral

120V
Duplex
Receptacle

Neutral

Neutral
Neutral

Equipment Ground

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1
1

Equipment Ground

1
Two-Pole Shared Neutral with
Multi-Duplex Receptacle Application

Single-Pole 120V Load Application Sourced by 120/240 Vac

1

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
Line B

Line B

1
1

Single-Pole

Two-Pole

Neutral
Neutral

Neutral

Two 120V
Duplex
Receptacles

Neutral

120V
Duplex
Receptacle

1
1

Equipment Ground

Equipment Ground

1

Line A

Two-Pole 240V Load Application Sourced by 120/240 Vac

Single-Pole 120V Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
Line B

Two-Pole

Neutral

1
1

Line B

1
1

Single-Pole
Line A

1

240V
Duplex
Receptacle

Neutral
Neutral

120V
Duplex
Receptacle

1
1

Equipment Ground

1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

83

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Two-Pole 120V Multi-Duplex Receptacle Application
120/240 Vac
Source
N A B
Line B

1
1

Two-Pole
Neutral

1
Neutral

Two 120V
Duplex
Receptacles

1
1
1
1
1

Line A

Two-Pole 120V Duplex Receptacle Application
120/240 Vac
Source
N A B
Line B
Line A

1
1

Two-Pole
Neutral

1

Neutral

1

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1
1

Two-Pole 240V Duplex Receptacle Application

1

120/240 Vac
Source
N A B

1

Line B

1
Two-Pole

1

Line A
Neutral

1

240V
Duplex
Receptacle

1
1
1
1
1
1
1
1
1
84

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Dimensions
Approximate Dimensions in Inches (mm)

1

Residential/Commercial/New York City Loadcenters, Unit Enclosures—Box Sizes

1

Note: Box sizes do not include covers/fronts.

1

Residential Loadcenters—NEMA Type 1 Indoor

Commercial Loadcenters—NEMA Type 1 Indoor

Box Size

Depth

Box Size

Height

Width

Depth

Height

Width

A1

15.00 (381.0)

11.25 (285.8)

3.75 (95.3)

19

44.00 (1117.6)

16.16 (410.4)

6.25 (158.8)

B1

16.75 (425.5)

14.31 (363.5)

3.88 (98.4)

20

44.00 (1117.6)

16.16 (410.4)

6.25 (158.8)

B2

18.75 (476.3)

14.31 (363.5)

3.88 (98.4)

22

54.00 (1371.6)

16.22 (412.0)

6.31 (160.3)

C1

21.00 (533.4)

14.31 (363.5)

3.88 (98.4)

24

66.50 (1689.1)

16.22 (412.0)

6.31 (160.3)

C2

23.00 (584.2)

14.31 (363.5)

3.88 (98.4)

C4

27.00 (685.8)

14.31 (363.5)

3.88 (98.4)

D1

29.13 (739.8)

14.31 (363.5)

3.88 (98.4)

G1

34.13 (866.8)

14.31 (363.5)

3.88 (98.4)

L1

39.00 (990.6)

14.31 (363.5)

3.88 (98.4)

L2

45.00 (1143.0)

14.31 (363.5)

3.88 (98.4)

2

8.63 (219.1)

5.00 (127.0)

3.50 (88.9)

3

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

4

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

5

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

6

12.00 (304.8)

6.88 (174.6)

4.50 (114.3)

7

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

9

14.50 (368.3)

6.50 (165.1)

3.50 (88.9)

1
1
1
1
1

Commercial Loadcenters—NEMA Type 3R Outdoor
Box Size

Height

Width

Depth

42

38.00 (965.2)

16.31 (414.3)

6.38 (161.9)

43

44.00 (1117.6)

16.31 (414.3)

6.38 (161.9)

46

54.00 (1371.6)

16.31 (414.3)

6.38 (161.9)

47

66.56 (1690.7)

16.31 (414.3)

6.38 (161.9)

1
1
1
1

New York City Loadcenters—NEMA Type 1 Indoor
Box Size

Height

Width

Depth

A

38.00 (965.2)

18.13 (460.4)

5.00 (127.0)

B

44.00 (1117.6)

18.13 (460.4)

5.00 (127.0)

C

66.50 (1689.1)

18.13 (460.4)

6.25 (158.8)

1
1
1

Residential Loadcenters—NEMA Type 3R Outdoor
Box Size

Height

Width

Depth

B1R

16.75 (425.5)

14.31 (363.5)

5.19 (131.8)

B2R

18.75 (476.3)

14.31 (363.5)

5.19 (131.8)

C3R

25.00 (635.0)

14.31 (363.5)

5.19 (131.8)

D1R

29.13 (739.8)

14.31 (363.5)

5.19 (131.8)

G1R

34.13 (866.8)

14.31 (363.5)

5.19 (131.8)

L1R

39.00 (990.6)

14.31 (363.5)

5.19 (131.8)

L2R

45.00 (1143.0)

14.31 (363.5)

5.19 (131.8)

2R

8.63 (219.1)

5.00 (127.0)

3.50 (88.9)

3R

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

4R

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

5R

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

6R

11.75 (298.5)

6.50 (165.1)

4.50 (114.3)

7R

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

8R

27.00 (685.8)

10.50 (266.7)

4.75 (120.7)

9R

14.25 (362.0)

6.50 (165.1)

4.00 (101.6)

C1R

21.00 (533.4)

14.31 (363.5)

5.19 (131.8)

Types ECB and ECC Unit Enclosures—NEMA Type 1 Indoor
Height

Width

Depth

23.25 (590.6)

8.88 (225.4)

4.50 (114.3)

1
1
1

Types ECB and ECC Unit Enclosures—NEMA Type 3R
Outdoor
Height

Width

Depth

23.68 (601.7)

9.31 (236.5)

5.44 (138.1)

1

1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

85

1.2
1
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Approximate Dimensions in Inches (mm)
Residential Loadcenter Knockouts
Knockouts for Box Sizes A1, B1, B2, C1, C2, C4, D1, G1, L1,
L2, B1R, B2R, C1R, C3R, D1R, G1R, L1R, L2R
Code

Diameter

A

0.50 (12.7)

0.75 (19.1)

—

—

—

1

B

0.50 (12.7)

—

—

—

—

C

0.50 (12.7)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

1

D

1.25 (31.8)

1.25 (31.8)

2.00 (50.8)

2.50 (63.5)

—

E

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

—

F

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.50 (38.1)

2.00 (50.8)

G

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

—

1

1
1
1

Residential NEMA Type 1 Indoor and
NEMA Type 3R Outdoor Enclosures
2.06 (52.3) Dia.
(125A
A Max.)
3.06 (77.7) Dia.
(225A
A Max.)

Hub

D

D

E

B

E

D

D

E

.45 (11.4) Dia. KO

H

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

I

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

J

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

A B B
B
B
B B

A
E

B B
B H
B

I

B

A
A

Outdoor Boxes
B1R, B2R, C1R, C3R, D1R,
G1R, L1R, L2R

—

1

B

B

B

J

B

B

B

E

A

B

B

1
1

J

J

A

A

B
B

B
B

1

B
B

B

B

J

A

E

J

J

J

1

B

B

B

E

B

1

J

B

B

B

A

B

Indoor Boxes
A1

1

.45 (11.4) Dia. KO
B

A
H

1

A

1

D

B

B

B

I

B
B

B

B

B

E

E

A
B

E

D

D

D

E

E
A
B
A B

A

B
B A

1

B

A

B

A

E

E
D

1

D

D

D

.45 (11.4) Dia. KO
A

A

1

E

B

I

B

H

B

B

A

Indoor Boxes
B1, B2

1
1

.45 (11.4) Dia. KO
B

A
H
A

1

D

D

A

I

B
B

B

B

B

E

E

B

B

E

D

D

1

A
B
B A

E
A
B
A B

1

B A
B
A
E

A B
B
A
E

E

D

D

D

1

D

.45 (11.4) Dia. KO

1

E

B

B

A
B

I

B
B

B

A
H

B
B

B

A

Indoor Boxes
C1, C2, C4, D1, G1, L1, L2

1
1
86

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Approximate Dimensions in Inches (mm)

1

Knockouts for Box Sizes 3, 4, 5, 6, 7, 9, 2R, 3R, 4R, 5R, 6R,
7R, 8R, 9R
Code

Diameter

A

0.50 (12.7)

—

—

—

B

0.50 (12.7)

0.75 (19.1)

—

—

C

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

D

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

E

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

—

F

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

G

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

H

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

I

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

1
1
1
1
1
1
1
1

Residential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures
Mounting
Hole for
5/16 (7.9)
Screw

–1.25 KO
–31.8) KO

R

F

.50–.75
(12.7–19.1)

Hub

A

A

E

2.38
(60.3)

6.38
3
(161.9)
1

A

A

A

B

A

E

A

G

A

A A A

1

B B

G

1

A

D
C

.50– –
(12.7 19.1 25.4)

–
–

1

B B

A

G

B

.31 (7.9)
.50–
(12.7–

D

A A A

C

Box 2, 2R

D

G

A

A

F

A

Box 3

A A A

A

F

D
A

A

B

A

G

1

A A A

G
D

Box 3R

1

B B

A

Box 4

1
A

F

Hub

B

Hub

A

A

A

D

B

H

A

C

F

Hub

F

1

F

1

A
A

G

D

G
A A A

D

A A A

G

B

D

A

B C

G

A

G

D

F

A

Box 5

Box 4R

A A A

D

A

F

B B

D

D

A

B

Hub

Hub

C
A A A

B C

F
A A A

G

A

Box 7

B B

C

C
G

G

F

C
A A A

B C

G

G

I

C

I

C

A A A
A

Box 7R

B B

F
B

I

A A

C B

B C

Box 8R

1

B

1

Box 6R

1

B

Hub

G

G

A

1

G

B

B
B
B

1

B

G

G

G

A
A A

1

D

B

H

B

A

C
G

B

D

A

H

B

C

A

F

Box 6
A

B B

C

Box 5R

A A A

A

G

F

F

A

B

C

B

A

B B

G

B

B

A

G
A

C

G

G
G

A

B

Box 9

G

1

C

1

A

Box 9R

1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

87

1.2
1
1
1

Type BR Loadcenters and Circuit Breakers

Approximate Dimensions in Inches (mm)
Commercial Loadcenter Knockouts
Indoor Commercial Enclosures

NEMA Type 1 Indoor Commercial Enclosures
Knockouts for Box Sizes 19, 20, 22, 24
Code

1

Loadcenters and Circuit Breakers

A

Diameter

A

0.50 (12.7)

—

—

—

1

B

0.50 (12.7)

0.75 (19.1)

—

—

C

0.75 (19.1)

1.00 (25.4)

1.50 (38.1)

—

1

D

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

3.00 (76.2)

E

2.00 (50.8)

2.50 (63.5)

3.00 (76.2)

—

F

2.50 (63.5)

3.00 (76.2)

3.50 (88.9)

—

1

H

E

A

C

H

E

C

1
1

NEMA Type 3R Outdoor Commercial Enclosures
Knockouts for Box Sizes 42, 43, 46, 47
Code

Diameter

A

0.50 (12.7)

—

—

—

1

B

0.50 (12.7)

0.75 (19.1)

—

—

C

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

—

1

D

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

—

E

2.00 (50.8)

2.50 (63.5)

3.00 (76.2)

—

F

2.50 (63.5)

3.00 (76.2)

3.50 (88.9)

—

G

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

H

3.25 (82.6) Sq.

—

—

—

1

1
1

D

D

A

C

D
B
B B

F

D

E

E

A

E

C

E
B
B B

F

E

E

Box 22, 24

Box 19, 20

Outdoor Commercial Enclosures

1
1
1
1
1
1

Unit Enclosure Knockouts, Types ECB and ECC Knockouts
Code

HUB

HUB

HUB

HUB

Diameter

NEMA Type 1 Indoor (Flush and Surface Trims)
A

0.50 (12.7)

—

—

—

—

B

1.25 (31.8)

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

NEMA Type 3R Outdoor
A

0.50 (12.7)

—

—

—

—

B

1.25 (31.8)

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

1
1

E

D

E

E

D

E

D
C

1

B B B
B

G

F

C

E

B B B
B

A

A

1

Box 42

1

Unit Enclosure Knockouts
A

1
1

E

D

E

F

Box 43, 46, 47

B

HUB

B

B

B

B

B

B

1
1

B

1

A

NEMA Type 1—Indoor

88

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

B

B
B

B
A

NEMA Type 3R—Outdoor

Loadcenters and Circuit Breakers
Loadcenter Interiors

1.3

Contents

OEM Loadcenters

Description

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications. . . . . . . . . . . . . . . . . . . . . . . . .

91
90

1
1
1
1
1
1
1
1
1
1
1

Product Description
As a leader in the electrical
distribution equipment
business, Eaton has a
unique product offering for
equipment manufacturers,
panel builders and virtually
any OEM that has a need
for power distribution within
their equipment. The OEM
interior offering consists
of a wide variety of power
distribution options utilizing
components from Eaton’s CH
and BR loadcenter product
lines. With high-volume,
standardized products,
OEMs can expect to
receive high-quality products
covering configurations
meeting virtually any power
distribution need.
Coupled with Eaton’s
expertise in circuit breaker
design and manufacturing,
OEM interiors provide solid
power distribution and circuit
protection in a compact,
easy-to-install package.
Interiors are offered from
2 to 42 circuits and from
70 to 225A.

Quality
Built in ISO 9002 certified
manufacturing facilities,
customers can be assured
of the process quality in place
for the manufacture of these
products. Utilizing the latest
in computer-controlled
plating, painting, molding,
stamping and welding
processes, Eaton’s
customers have come to
expect consistent high-quality
from shipment to shipment.

Two Products Offer
Design Flexibility
As a manufacturer of two
lines of loadcenters, Eaton
is in a unique position to
offer the broadest range of
interiors in the market. Each
line has its own unique
characteristics that appeal
to various segments of the
market. OEM interiors are
UL recognized components
and are listed in either of
the following UL files: E8741
or E52977.

The CH interiors feature
100% copper bus and use
the CH 3/4-inch (19.1 mm)
wide circuit breaker, which
minimizes panel space.
Recognized by contractors
for its sturdy design, the
CH interior will appeal to
those customers seeking
an industrial quality bolted
bus bar and the space saving
of 3/4-inch (19.1 mm) per
bus stab. With a typical
12 circuit CH interior, this
space savings amounts
to an inch and a half savings
over its 1-inch (25.4 mm)
counterparts. The stab
rating of the CH interiors
is 140A maximum meaning
that the handle rating of
breakers mounted across
from one another may not
exceed 140A.

The stab rating of the BR
interiors is 200A maximum,
meaning that the handle
rating of the breakers that
are mounted across from
one another may not
exceed 200A.

1
1
1

The interiors are designed
for either horizontal (singlerow breaker mounting), or
vertical (double-row breaker
mounting). To comply with
National Electrical Code
(NEC) requirements, if
mounted horizontally, when
the breaker is ON, the handle
should be in the UP position.
When mounted vertically, the
handle toggles from left to
right, so this is not a concern.

1
1
1
1
1
1
1
1

The BR interiors are
manufactured of formed,
plated aluminum or copper,
and use Eaton’s Type BR
1-inch (25.4 mm) wide circuit
breaker. This design affords
customers the most circuit
flexibility as many of these
interiors allow the installation
of standard single- and
two-pole breakers as well as
duplex (two poles in a 1-inch
(25.4 mm) space) or quadplex
(four poles in a 2-inch
(50.8 mm) space) breakers.

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

89

1.3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Loadcenter Interiors

Standards and Certifications
Class CTL

Federal Specifications

National Electrical Code
Paragraph 384-15 requires
branch circuit panelboards
to be provided with physical
means to prevent the
installation of more
overcurrent devices than
that number of which the
enclosure was designed,
rated and approved. Class
CTL Duplex, Quadplex and
twin breakers (identified
by a catalog number prefix
BD, BQ, BQC and CHT)
are equipped with a
UL listed rejection tab
over the line terminal.
All OEM interiors have
appropriately notched stabs
to accept these rejection
tab Class CTL breakers.

All loadcenter enclosures
meet Federal Specifications
W-P-115b, Type 1, Class 2
requirements.

Duplex, Quadplex and twin
breakers manufactured
without the rejection tab
(identified by a catalog
number prefix BR, BRD
and CHNT) are available
for replacement purposes
in older interiors.

All 120/240V breakers, both
1-inch (25.4 mm), 1/2-inch
(12.7 mm) and 3/4-inch
(19.1 mm) per pole meet
the requirement of Federal
Specifications W-C 375B/
Gen Type 1.

Canadian Standards
Association Listing
All single-pole and two-pole,
120/240V breakers, both
1-inch (25.4 mm), 1/2-inch
(12.7 mm) and 3/4-inch
(19.1 mm) per pole, 225A
maximum, are listed as
Certified by the Canadian
Standards Association, Guide
No. 69-11.19, Class 1432,
File 18328.

Underwriters
Laboratories Listing

Lighting and
Appliance Panelboards

All grounding bars
manufactured comply
with Underwriters
Laboratories standards
and are listed under
Guide No. DHJR, File
E31424, Volume W,
Section 17.

Lighting and appliance
branch circuit panelboards are
defined in NEC (Article 384)
as “One having more than
10 percent of its overcurrent
devices rated 30A or less for
which neutral connections
are provided.” Article 384
also limits the number of
overcurrent devices (branch
circuit poles) to a maximum
of 42 in any one cabinet.
When the 42 poles are
exceeded, two or more
separate panels are required.

All circuit breakers 10A
and larger comply with the
Underwriters Laboratories
“Standard for Branch
Circuit and Service CircuitBreakers” UL 489; Guide
No. 60 10.2 File E31424, and
“Requirements for Wire
Connectors and Soldering
Lugs,” UL 486B, Guide
No. 461 10-C File E7830.
All Eaton breakers where
marked, are suitable for use
with 60/75ºC rated wire,
unless otherwise specified.
All devices comply with the
22 kAIC–10 kAIC UL series
connected components File
DKSY2 of the Recognized
Components Index.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
90

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

For more details and
engineering drawings,
see BR.31.02.S.E.

Loadcenters and Circuit Breakers
Loadcenter Interiors

1.3

Product Selection
BR Loadcenter
Interior Assembly

1
1

Type BR Loadcenter Interior Assemblies
Ampere
Rating

Maximum Number 1-Inch (24.5 mm)
Spaces
Single Poles

UL File
Reference

Main Terminal Size
(Per Phase)

Standard
Package Quantity

Catalog
Number

1
1

Single-Phase Single Row Breaker Mounting—Aluminum Bus—120/240 Vac, Three-Wire
70

2

4

—

(1) #8–#2 AWG Cu/Al

20

24INT70B

125

2

4

E8741

(1) 1/0–#14 AWG Cu
2/0–12 AWG All

20

24INT125B

1

125

6

12

E52977

(1) 2/0–#14 AWG Cu/Al

20

612INT125SRB

1
1

Single-Phase Double Row Breaker Mounting—Aluminum Bus—120/240 Vac, Three-Wire
125

4

8

E8741

(1) 2/0–#14 AWG Cu/Al

20

48INT125B

125

6

12

E8741

(1) 2/0–#14 AWG Cu/Al

20

612INT125B

125

8

16

E8741

(1) 2/0–#14 AWG Cu/Al

20

816INT125B

125

12

812

E52977

(1) 2/0–#14 AWG Cu/Al

20

1212INT125B

125

12

24

E52977

(1) 2/0–#14 AWG Cu/Al

20

1224INT125B

125

16

24

E52977

(1) 2/0–#14 AWG Cu/Al

20

1624INT125B

125

20

24

E52977

(1) 2/0–#14 AWG Cu/Al

10

2024INT125B

125

24

24

E52977

(1) 2/0–#14 AWG Cu/Al

10

2424INT125B

200

8

16

E52977

(1) 300 kcmil–#1 AWG Cu/Al

20

816INT200B

200

12

24

E52977

(1) 300 kcmil–#1 AWG Cu/Al

20

1224INT200B

200

30

40

E52977

(1) 300 kcmil–#1 AWG Cu/Al

10

3040INT200B

200

42

42

E52977

(1) 300 kcmil–#1 AWG Cu/Al

10

4242INT225B

1
1
1
1
1
1
1

Single-Phase Double Row Breaker Mounting—Copper Bus—120/240 Vac, Three-Wire
125

8

16

E5297

(1) 2/0–#14 AWG Cu/Al

20

816INT125BC

125

12

12

E5297

(1) 2/0–#14 AWG Cu/Al

20

1212INT125BC

200

12

24

E5297

(1) 300 kcmil–#1 AWG Cu/Al

20

1224INT200BC

Three-Phase Double Row Breaker Mounting—Aluminum Bus—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—
120/240 Vac, Four-Wire Delta
125

12

34

E52977

(1) 2/0–#8 AWG Cu/Al

10

1224INT3125B

150

18

36

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

1836INT3150B

150

24

42

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

2442INT3150B

200

30

42

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

3042INT3200B

225

42

42

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

4242INT3225B

Three-Phase Double Row Breaker Mounting—Copper Bus—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—
120/240 Vac, Four-Wire Delta
125

12

24

E52977

(1) 2/0–#8 AWG Cu/Al

10

1224INT3125BC

200

12

24

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

1224INT3200BC

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

91

1.4
1

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Contents

Classified Breakers

Description

1

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1

93
95
95
96

1
1
1
1
1
1
1
1
1
1
1
1
1

Product Description
Eaton UL classified
Replacement Circuit Breakers
are available in both 3/4-inch
Type CHQ and 1-inch Type
CL, single- and two-pole
configurations. These
breakers are classified as
direct replacements by
Underwriters Laboratories.
In addition to a UL listing,
they also come with a
15-year warranty.

1

Specified vs. UL Classified

Testing

Specified breakers are listed
by the manufacturer of the
panelboard for use in a
particular panel. This doesn’t
mean that the panelboard
manufacturer produced the
specified breaker; it merely
means that the panelboard
manufacturer has tested the
breaker in the panel. In fact,
through the years, Eaton has
manufactured thousands of
breakers for other panelboard
manufacturers.

Classified breakers are
tested extensively in
numerous General Electric®,
Siemens®, Murray®,
Thomas & Betts®, Square D®,
and Crouse-Hinds® panels.
The tests are conducted with
witnesses from Underwriters
Laboratories Inc. and involve
short-circuit, temperature,
and insertion/withdrawal
applications. This level of
testing ensures that the
breakers meet identified
standards and have been
found suitable by UL for
the specified purpose.

UL classified breakers
are produced by one
manufacturer for use in
place of the breakers
specified on the panelboard.
Like specified breakers,
UL classified breakers have
been tested in the panels for
which they are approved.

1
1
1
1
1

Understanding Classified
Breaker Terminology
Definitions
Specified circuit breaker—
each manufacturer lists
the brands of circuit
breakers that can be used
in their panelboards. Often,
manufacturers will not list
competitors as specified,
even though they are
suitable replacements.
Classified circuit breaker—
a breaker that is considered
suitable, by a qualified thirdparty organization, for use
in another manufacturer’s
panelboard.
Listed breaker—the listing
of a circuit breaker is by an
independent third party. Eaton
classified breakers are listed
by UL.
Labeled breaker—a breaker
with a label affixed by an
independent third party.

1
1
1
1
1
1
1
92

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Classified Circuit Breakers

1.4

Product Selection

1

Type CHQ Replacement Breakers for Square D Type QO Loadcenters

1

10 kAIC, 120 and 120/240 Vac
CHQ120 CHQ230

1

Type CHQ Classified Breakers 3/4-Inch (19.1 mm) per Pole
120 or 120/240 Vac, 10 kAIC

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

20

Single-Pole 120/240 Vac
Requires One
3/4-Inch (19.1 mm) Space
10 per Shelf Carton
Catalog Number

Two-Pole 120/240 Vac
Common Trip Requires Two
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton
Catalog Number

CHQ115

CHQ215

CHQ120

CHQ220

25

CHQ125

CHQ225

30

CHQ130

CHQ230

35

CHQ135

CHQ235

40

CHQ140

CHQ240

45

CHQ145

CHQ245

50

CHQ150

CHQ250

60

—

CHQ260

1
1
1
1
1
1
1
1
1
1

Type CHQ Ground Fault and Arc Fault Replacement Breakers for Square D Type QO Loadcenters

1

10 kAIC, 120 and 120/240 Vac
CHQ115GF CHQ220GF

1

Type CHQ Ground Fault Breakers—5 Milliampere—
3/4-Inch (19.1 mm) per Pole, 10 kAIC

1
1

Single-Pole 120 Vac
Requires One
3/4-Inch (19.1 mm) Space
10 per Shelf Carton
Catalog Number

Two-Pole 120/240 Vac
Common Trip Requires Two
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton
Catalog Number

CHQ115GF

CHQ215GF

CHQ120GF

CHQ220GF

25

CHQ125GF

CHQ225GF

30

CHQ130GF

CHQ230GF

35

—

CHQ235GF

40

—

CHQ240GF

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

20

45

—

CHQ245GF

50

—

CHQ250GF

1
1
1
1
1
1
1
1

Type CHQ Surge Arrester
Catalog Number

1

CHQSA

1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

93

1.4
1

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Type CL Replacement Breakers for Square D HOMELINE, General Electric, Crouse-Hinds,
Thomas & Betts, Murray and ITE®/Siemens Loadcenters

1
1

CL_

Type CL Breakers, 1-Inch (25.4 mm) per Pole, 10 kAIC

1
Ampere
Rating

Wire Size
Range Cu/Al
60°C or 75°C

Single-Pole 120/240V
Requires One
1-Inch (25.4 mm) Space
10 per Shelf Carton
Catalog Number

15

#14–4

CL115

CL215

1

20

#14–4

CL120

CL220

25

#14–4

CL125

CL225

1

30

#14–4

CL130

CL230

35

#14–4

CL135

CL235

1

40

#14–4

CL140

CL240

45

#14–4

CL145

CL245

50

#14–4

CL150

CL250

1
1

1

Two-Pole 120/240V
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
Catalog Number

1
1

CL_AF

Type CL Classified Arc and Ground Fault Breakers (5 Milliampere),
1-Inch (25.4 mm) per Pole, 10 kAIC

1
1
Ampere
Rating

1

Wire Size
Range Cu/Al
60°C or 75°C

Single-Pole 120/240V
Requires One 1-Inch (25.4 mm) Space
1 per Shelf Carton
Catalog Number

Arc Fault Breakers

1

15

#14–4

CL115AF

20

#14–4

CL115CAF

20

#14–4

CL120AF

1

20

#14–4

CL120CAF

1

15

#14–4

CL115AFGF

20

#14–4

CL120AFGF

1

Arc Fault/Ground Fault Breakers

1

Ground Fault Breakers

1

15

#14–4

CL115GF

20

#14–4

CL120GF

1

30

#14–4

CL130GF

1
CLR_

1

Type CL Classified Latching Remote Control Smart Breakers,
1-Inch (25.4 mm) per Pole, 10 kAIC

1
Ampere
Rating

Wire Size
Range Cu/Al
60°C or 75°C

Single-Pole 120V
Requires One
1-Inch (25.4 mm) Space
10 per Shelf Carton
Catalog Number

15

(2) #14–10

CLRP115

CLRP215

1

20

(2) #14–10

CLRP120

CLRP220

25

(1) #8–6

CLRP125

CLRP225

1

30

(1) #8–6

CLRP130

CLRP230

1
1

Two-Pole 120/240V
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
Catalog Number

1
94

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Accessories

1.4

Technical Data

CHQ Breaker Accessories
Description

Catalog
Number

Breaker handle lock

CHLO

Arc Fault Application Notes
An arc fault circuit interrupter
is a device intended to
provide protection from
the effects of arc faults by
recognizing characteristics
unique to arcing and by
functioning to de-energize
the circuit when the arc
fault is detected. As of
January 1, 2002, the
National Electrical Code
(NEC) requires all branch
circuits that supply 125V,
single-phase, 15 and 20A
receptacle outlets installed
in dwelling unit bedrooms
shall be protected by an arc
fault circuit interrupter(s).
This includes ceiling lighting
(recessed, ceiling fans, etc.)
as well as smoke detectors
and all other bedroom
outlets. The 2005 NEC
introduced the application of
the Combination Type AFCI
for bedroom circuits required
as of January 1, 2008. The
2008 NEC expands this
application to other living
areas.

1

Ground Fault
Application Notes

1

Single-pole GFCBs are
designed for use in two-wire,
120 Vac circuits. Drawing
on Page 96 shows a typical
wiring configuration.

1
1

Two-pole GFCBs are
designed for use in threewire, 120/240 Vac circuits,
120 Vac multiwire circuits
employing common, neutral
and two-wire, 240 Vac
circuits obtained from a
120/240 Vac source.

1

Drawings on Page 96
illustrate typical wiring
configurations for
120/240 Vac multiwire
circuits.

1

1
1
1
1
1

Drawing on Page 96 depicts
a 240 Vac, two-wire circuit.
Note the “panel neutral”
conductor connects to the
neutral bar, even though the
neutral is not included in the
load circuit. This connection
is necessary to supply a
120 Vac power source to the
ground fault sensing circuit.

1
1
1
1
1

The figures are shown with
a 120/240 Vac, single-phase,
three-wire power source,
ut are also applicable to a
120/208 Vac, three-phase,
four-wire power supply.
For all figures, the electrical
operation of the GFCB
is not affected by the
equipment ground.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

95

1.4
1
1
1

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Wiring Diagrams
Single-Pole 120V Load Application Sourced by 120/240 Vac

Two-Pole 240V Load Application Sourced by 120/240 Vac

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B
Line B

Line B

1
1

Two-Pole

Single-Pole
Neutral

1

Neutral

1

120V
Duplex
Receptacle

240V
Duplex
Receptacle

Line A
Neutral

Equipment Ground

Equipment Ground

1
1
1

Two-Pole Shared Neutral with
Multi-Duplex Receptacle Application

Two-Pole Shared Neutral with
Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1

Line B

Line B
Line A

1
Two-Pole

Two-Pole

1

Neutral
Neutral

1

Two 120V
Duplex
Receptacles

Neutral
Neutral

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

Equipment Ground

1
Equipment Ground

Line A

1
1
1

Single-Pole 120V Duplex Receptacle Application

Two-Pole 120V Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B
Line B

Line B

1
1

Line A

Two-Pole

Single-Pole
Neutral

1

Neutral

120V
Duplex
Receptacle

Neutral
Neutral

1

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1
1
1

Two-Pole 120V Multi-Duplex Receptacle Application

Two-Pole 240V Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B
Line B

Line B

1
1

Two-Pole

Two-Pole
Neutral

1

Neutral

Two 120V
Duplex
Receptacles

Line A
Neutral

1
1

Line A

96

Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com

240V
Duplex
Receptacle



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2010:12:13 17:15:31Z
Modify Date                     : 2010:12:15 13:59:58-05:00
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Creation Date                   : 2010:12:13 17:15:31Z
Mod Date                        : 2010:12:15 13:59:58-05:00
Author                          : Zoltun Design
Metadata Date                   : 2010:12:15 13:59:58-05:00
Document ID                     : uuid:b6d2abcb-06de-11e0-a0df-000393c32d16
Instance ID                     : uuid:c3ed9e2b-0871-11e0-9b11-000393c32d16
Format                          : application/pdf
Title                           : Vol1_Tab01
Creator                         : Zoltun Design
Page Count                      : 96
Page Layout                     : SinglePage
EXIF Metadata provided by EXIF.tools

Navigation menu