0613PL0001R0713
109128-Catalog 109128-Catalog 109128-Catalog 785901 Batch5 unilog cesco-content
2014-06-03
: Pdf 104205-Attachment 104205-Attachment 785901 Batch4 unilog
Open the PDF directly: View PDF .
Page Count: 30
Download | |
Open PDF In Browser | View PDF |
Masterpact™ NT/NW Universal Power Circuit Breakers Pricing Guide 0613PL0001 R07/13 2013 Class 613 CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 ANSI C37/UL 1066 Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Basic Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Circuit Breaker/Cradle Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 ArcBlok™ Circuit Breakers Basic Block . . . . . . . . . . . . . . . . . . . . . . . . . .7 ArcBlok Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 UL 489 Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Basic Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Circuit Breaker/Cradle Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 ArcBlok™ Circuit Breakers Basic Block . . . . . . . . . . . . . . . . . . . . . . . . . 11 ArcBlok Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 DC Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 IEC 60947-2 Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Basic Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Circuit Breaker/Cradle Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 DC Circuit Breakers and Non-Automatic Switches . . . . . . . . . . . . . . . .16 Trip Unit and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Appendices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 ™ Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Introduction This document is intended to provide pricing for a complete circuit breaker with cradle and required accessories, as well as field-installable accessory kits. Refer to the Masterpact NT/NW Universal Power Circuit Breaker Catalog (0613CT0001) for product descriptions. For assistance in creating a complete breaker and cradle catalog number, please contact your nearest Square D/Schneider Electric sales office. To price a complete circuit breaker, first determine the rating required: ANSI C37/UL 1066 (page 3) UL 489 (page 8) IEC 60947-2 (page 13) Then include: 1. 2. 3. 4. Basic Block Cradle (for drawout circuit breaker) Circuit Breaker/Cradle Connectors Trip Unit and Options (page 17) Optional: 1. 2. 3. Circuit Breaker Accessories (page 19) Cradle Accessories (page 20) Miscellaneous Accessories (page 22) Please see Appendix A (pages 25–27) for a request for quotation form. 2 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers ANSI C37/UL 1066 Rated Basic Block Please contact your nearest Square D/Schneider Electric sales office for assistance in building a complete circuit breaker or switch catalog number. Table 1: Frame Rating (A) T-, W-, and Y-Frame Drawout Circuit Breaker Model Number Interrupting Rating (kA) Sensor Plug (A) $ Price 254 V 508 V 635 V 3-Pole 4-Pole 42 42 — 100,250,400,600,800 11726.00 17588.00 T-Frame 800 NT08N1 W-Frame 800 1600 2000 3200 NW08N1 42 42 42 100, 250, 400, 600, 800 13028.00 19542.00 NW08H1 65 65 65 100, 250, 400, 600, 800 14942.00 22412.00 NW08H2 85 85 85 100, 250, 400, 600, 800 18026.00 27040.00 NW08H3 100 100 85 100, 250, 400, 600, 800 19626.00 NW08L1 200 200 130 100, 250, 400, 600, 800 21226.00 N/A NW08L1F 200 200 130 100, 250, 400, 600, 800 22276.00 N/A NW16N1 42 42 42 800, 1000, 1200, 1600 20256.00 30384.00 NW16H1 65 65 65 800, 1000, 1200, 1600 24152.00 36230.00 NW16H2 85 85 85 800, 1000, 1200, 1600 27980.00 41970.00 NW16H3 100 100 85 800, 1000, 1200, 1600 33470.00 NW16L1 200 200 130 800, 1000, 1200, 1600 38960.00 N/A NW16L1F 200 200 130 800, 1000, 1200, 1600 40010.00 N/A NW20H1 65 65 65 1000, 1200, 1600, 2000 28486.00 42728.00 NW20H2 85 85 85 1000, 1200, 1600, 2000 38556.00 57834.00 NW20H3 100 100 85 1000, 1200, 1600, 2000 41812.00 NW20L1 200 200 130 1000, 1200, 1600, 2000 45064.00 N/A NW20L1F 200 200 130 1000, 1200, 1600, 2000 46114.00 N/A NW32H1 65 65 65 1600, 2000, 2500, 3000, 3200 48124.00 NW32H2 85 85 85 1600, 2000, 2500, 3000, 3200 61336.00 92002.00 NW32H3 100 100 85 1600, 2000, 2500, 3000, 3200 68696.00 103040.00 29440.00 50204.00 62714.00 72184.00 Y-Frame 3200 4000 5000 6000 a b NW32L1 200 200 130 1600, 2000, 2500, 3000, 3200 76056.00 N/A NW40H2 85 85 85 2000, 2500, 3000, 3200, 4000 81252.00 121874.00 NW40H3 100 100 85 2000, 2500, 3000, 3200, 4000 91002.00 NW40L1 200 200 130 2000, 2500, 3000, 3200, 4000 122853.00 136498.00 N/A NW50H2 85 85 85 2500, 3000, 3200, 4000, 5000 95242.00 143132.00 NW50H3 100 100 85 2500, 3000, 3200, 4000, 5000 106876.00 160308.00 NW50L1 200 200 130 2500, 3000, 3200, 4000, 5000 144283.00 N/A NW60H2 85 85 85 3000, 3200, 4000, 5000, 6000 112068.00 168098.00 NW60H3 100 100 85 3000, 3200, 4000, 5000, 6000 129415.00 188272.00 NW60L1 200 200 130 3000, 3200, 4000, 5000, 6000 174711.00 N/A Includes sensor plug. Tested to show the arc flash hazard risk category as referenced in NFPA70E. Table 2: Frame Rating (A) T-, W-, and Y-Frame Drawout Non-Automatic Switch Model Number 254 V Interrupting Rating (kA) 508 V 635 V Short-Time Rating (kA RMS) $ Price 42 42 — 42 12588.00 18880.00 3-Pole 4-Pole T-Frame 800 NT08NA W-Frame 800 NW08HA 65 65 65 65 14942.00 22412.00 1600 NW16HA 65 65 65 65 24152.00 36230.00 2000 NW20HA 65 65 65 65 28486.00 42728.00 3200 NW32HA 65 65 65 65 48124.00 72184.00 4000 NW40HA 85 85 85 85 81252.00 121874.00 5000 NW50HA 85 85 85 85 95424.00 143132.00 6000 NW60HA 85 85 85 85 112068.00 168098.00 Y-Frame a b When used in conjunction with an overcurrent relay, circuit breaker, or fuse. Includes sensor plug. © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Discount Schedule 3 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers ANSI C37/UL 1066 Rated Table 3: W- and Y-Frame Drawout Automatic Switch Frame Rating (A) Interrupting Rating (kA) Model Number 254 V 508 V Short-Time Rating (kA RMS) 635 V $ Price 3-Pole 4-Pole W-Frame 800 1600 NW08HF 100 100 85 85 19626.00 NW08HC 200 200 130 30 21226.00 NW16HF 100 100 85 85 33470.00 NW16HC 200 200 130 30 38960.00 NW20HF 100 100 85 85 41812.00 NW20HC 200 200 130 30 45064.00 3200 NW32HF 100 100 85 85 68696.00 3200 NW32HC 200 200 130 100 76056.00 NW40HF 100 100 85 85 91002.00 NW40HC 200 200 130 100 100752.00 2000 29440.00 N/A 50204.00 N/A 62714.00 N/A 103040.00 Y-Frame 4000 5000 6000 NW50HF 100 100 85 85 106876.00 NW50HC 200 200 130 100 118326.00 NW60HF 100 100 85 85 112068.00 NW60HC 200 200 130 100 138959.00 N/A 136498.00 N/A 160308.00 N/A 168098.00 N/A When used in conjunction with an overcurrent relay, circuit breaker, or fuse. Includes sensor plug. Table 4: FrameRating (A) T-, W-, and Y-Frame Fixed Circuit Breaker Model Number Interrupting Rating (kA) Sensor Plug (A) 254 V 508 V 635 V NT08N1 42 42 — 100,250,400,600,800 NW08N1 42 42 42 NW08H1 65 65 65 NW08H2 85 85 NW08H3 100 NW16N1 $ Price 3-Pole 4-Pole T-Frame 800 9960.00 14938.00 100, 250, 400, 600, 800 11856.00 17782.00 100, 250, 400, 600, 800 13598.00 20396.00 85 100, 250, 400, 600, 800 16406.00 24606.00 100 85 100, 250, 400, 600, 800 17860.00 26790.00 42 42 42 800, 1000, 1200, 1600 14382.00 21574.00 NW16H1 65 65 65 800, 1000, 1200, 1600 17148.00 25722.00 NW16H2 85 85 85 800, 1000, 1200, 1600 19866.00 29800.00 NW16H3 100 100 85 800, 1000, 1200, 1600 23764.00 35646.00 NW20H1 65 65 65 1000, 1200, 1600, 2000 19656.00 29482.00 NW20H2 85 85 85 1000, 1200, 1600, 2000 26604.00 39906.00 NW20H3 100 100 85 1000, 1200, 1600, 2000 28850.00 43272.00 NW32H1 65 65 65 1600, 2000, 2500, 3000, 3200 42348.00 63520.00 NW32H2 85 85 85 1600, 2000, 2500, 3000, 3200 53976.00 80962.00 NW32H3 100 100 85 1600, 2000, 2500, 3000, 3200 60452.00 NW40BH1 65 65 65 2000, 2500, 3000, 3200, 4000 62566.00 N/A W-Frame 800 1600 2000 3200 4000 90676.00 NW40BH2 85 85 85 2000, 2500, 3000, 3200, 4000 64680.00 N/A NW40BH3 100 100 85 2000, 2500, 3000, 3200, 4000 72442.00 N/A Y-Frame 4000 5000 6000 NW40H2 85 85 85 2000, 2500, 3000, 3200, 4000 68250.00 114562.00 NW40H3 100 100 85 2000, 2500, 3000, 3200, 4000 76440.00 128308.00 NW50H2 85 85 85 2500, 3000, 3200, 4000, 5000 93516.00 134544.00 NW50H3 100 100 85 2500, 3000, 3200, 4000, 5000 104738.00 150690.00 NW60H2 85 85 85 3000, 3200, 4000, 5000, 6000 110117.00 164075.00 NW60H3 100 100 85 3000, 3200, 4000, 5000, 6000 127491.00 189962.00 Includes sensor plug. 4 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers ANSI C37/UL 1066 Rated Table 5: Frame Rating (A) T-, W-, and Y-Frame Fixed Non-Automatic Switch Model Number 254 V Interrupting Rating (kA) 508 V 635 V Short-Time Rating (kA RMS) $ Price 800 NT08NA 42 42 — 42 10150.00 15162.00 3-Pole 4-Pole T-Frame W-Frame 800 NW08HA 65 65 65 65 13858.00 20702.00 1600 NW16HA 65 65 65 65 18116.00 27174.00 2000 NW20HA 65 65 65 65 19736.00 29602.00 3200 NW32HA 65 65 65 65 42430.00 4000 NW40BHA 65 65 65 65 57034.00 63642.00 N/A Y-Frame 4000 NW40HA 85 85 85 85 71638.00 107454.00 5000 NW50HA 85 85 85 85 84134.00 126198.00 6000 NW60HA 85 85 85 85 98810.00 148214.00 635 V Short-Time Rating (kA RMS) When used in conjunction with an overcurrent relay, circuit breaker, or fuse. Includes sensor plug. Table 6: Frame Rating (A) W- and Y-Frame Fixed Automatic Switch Model Number Interrupting Rating (kA) 254 V 508 V $ Price 3-Pole 4-Pole W-Frame 800 NW08HF 100 100 85 85 17860.00 26790.00 1600 NW16HF 100 100 85 85 23764.00 35646.00 2000 NW20HF 100 100 85 85 28850.00 43272.00 3200 NW32HF 100 100 85 85 60452.00 4000 NW40BHF 100 100 85 85 72442.00 4000 NW40HF 100 100 85 85 76440.00 128308.00 5000 NW50HF 100 100 85 85 104738.00 150690.00 6000 NW60HF 100 100 85 85 110491.00 164632.00 90676.00 N/A Y-Frame When used in conjunction with an overcurrent relay, circuit breaker, or fuse. Includes sensor plug. © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Discount Schedule 5 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers ANSI C37/UL 1066 Rated Cradle Circuit Breaker/Cradle Connectors Please contact your nearest Square D/Schneider Electric sales office for assistance in building a complete circuit breaker or switch catalog number. For a complete connector set, order both the “Top” and “Bottom” connector kits. Kits for use on both fixed and drawout circuit breakers unless noted. Table 7: Table 8: Frame Rating (A) Circuit Breaker/Switch Model Number Interrupting Rating / Withstand Rating (kA) $ Price Connector Circuit Breaker Switch NT08N1 NT08NA 42 42 — 3440.00 5166.00 NT08H1 NT08HA 42 42 — 3440.00 5166.00 254 V 508 V 635 V 3-Pole 1600 NW08N1 — 42 42 42 3822.00 5740.00 NW08H1 NW08HA 65 65 65 3822.00 5740.00 NW08H2 — 85 85 85 3822.00 5740.00 NW08H3 NW08HF 100 100 85 3822.00 5740.00 NW08L1 NW08HC 200 200 130 4544.00 NW08L1F — 200 200 130 4544.00 N/A NW16N1 — 42 42 42 3822.00 5740.00 NW16H1 NW16HA 65 65 65 3822.00 5740.00 NW16H2 — 85 85 85 3822.00 5740.00 NW16H3 NW16HF 100 100 85 3822.00 5740.00 NW16L1 2000 3200 N/A NW16HC 200 200 130 4544.00 N/A NW16L1F — 200 200 130 4544.00 N/A NW20H1 NW20HA 65 65 65 4250.00 6378.00 NW20H2 — 85 85 85 4250.00 6378.00 NW20H3 NW20HF 100 100 85 4250.00 6378.00 NW20L1 NW20HC 200 200 130 4592.00 N/A NW20L1F — 200 200 130 4592.00 NW32H1 NW32HA 65 65 65 9754.00 N/A 4000 NW32H2 — 85 85 85 9754.00 14638.00 NW32H3 NW32HF 100 100 85 9754.00 14638.00 5000 6000 6 NW32L1 NW32HC 200 200 130 12096.00 NW40H2 NW40HA 85 85 85 16206.00 24318.00 NW40H3 NW40HF 100 100 85 16206.00 24318.00 NW40L1 NW40HC 200 200 130 20094.00 Front Connected Flat (FCF) Rear Connected T Horizontal/Vertical (RCTH/RCTV) 800–1200 A 800–1200 A Kit Catalog Numberb Kit $ Price / Circuit Breaker Price Adder 3-Pole 4-Pole N/A 800–2000 A Front Connected Flat (FCF) 3200 Aa 4000 A 800–2000 A Front Connected T (FCT) 3200 Aa 4000 A 5000 A Rear Connected Offset Vertical (RCOV) 2000 Aa 3200 A 4000 Ae 800–2000 A Rear Connected T Horizontal/Vertical (RCTH /RCTV) NW50H2 NW50HA 85 85 85 28856.00 43284.00 NW50HF 100 100 85 28856.00 43284.00 NW50L1 NW50HC 200 200 130 29580.00 NW60H2 NW60HA 85 85 85 37068.00 55602.00 NW60H3 NW60HF 100 100 85 37068.00 55602.00 NW60L1 NW60HC 200 200 130 43480.00 N/A 3200 Aa 4000 A 5000 A 6000 A N/A NW50H3 Top SFCF12 716.00 954.00 Bottom SFCF12 716.00 954.00 Top SRCTV12 408.00 544.00 Bottom SRCTV12 408.00 544.00 W- and Y- Frame 14638.00 Y-Frame 3200 Location T-Frame W-Frame 800 Frame Rating 4-Pole T-Frame 800 Connectors c d e Top SFCF20T c 926.00 1386.00 Bottom SFCF20Bc 868.00 1304.00 Top SFCF20FTd 1030.00 1534.00 Bottom SFCF20FB d 956.00 1434.00 Top SFCF40 6252.00 9378.00 Bottom SFCF40 6252.00 9378.00 Top SFCT30c 1466.00 2198.00 Bottom SFCT30c 1466.00 2198.00 Top SFCT30d 1466.00 2198.00 Bottom SFCR30Bd 1488.00 2234.00 Top SFCT50 7196.00 10796.00 Bottom SFCT50 7196.00 10796.00 Top SRCOV32T 3402.00 5104.00 Bottom SRCOV32B 2004.00 3006.00 Top SRCOV40 4138.00 7078.00 Bottom SRCOV40 4138.00 5514.00 Top SRCTV20 796.00 1194.00 Bottom SRCTV20 796.00 1194.00 Top SRCTV50 5410.00 8114.00 Bottom SRCTV50 5410.00 8114.00 Top SRCTVA60 14988.00 22480.00 Bottom SRCTVA60 14988.00 22480.00 L1/L1F only. For a 4-pole connector kit, add the suffix (4) to the kit number (e.g. SFCF124). For drawout circuit breaker only. For fixed circuit breaker only. For 4000 A W-frame fixed circuit breakers only. N/A DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers ANSI C37/UL 1066 Rated Table 11: ArcBlok™ Circuit Breakers Basic Block Please contact your nearest Square D/Schneider Electric sales office for assistance in building a complete circuit breaker or switch catalog number. Table 9: Frame Rating (A) Model Number Interrupting Rating (kA) 254 V 508 V Sensor Plug (A) 635 V 1600 2000 3200 5000 f Interrupting Rating (kA)a 254 V 508 V 635 V Short-time Rating (kA RMS) $ Price b 3-Pole 800 NW08HF 100 100 85 85 22570.00 NW16HF 100 100 85 85 38491.00 $ Pricea 2000 NW20HF 100 100 85 85 48084.00 3-Pole 3200 NW32HF 100 100 85 85 79000.00 Y-Frame NW08N1 42 42 42 100, 250, 400, 600, 800 14982.00 4000 NW40HF 100 100 85 85 104652.00 NW08H1 65 65 65 100, 250, 400, 600, 800 17183.00 5000 NW50HF 100 100 85 85 122907.00 NW08H2 85 85 85 100, 250, 400, 600, 800 20730.00 NW08H3 100 100 85 100, 250, 400, 600, 800 22570.00 NW16N1 42 42 42 800, 1000, 1200, 1600 23294.00 NW16H1 65 65 65 800, 1000, 1200, 1600 27775.00 NW16H2 85 85 85 800, 1000, 1200, 1600 32177.00 NW16H3 100 100 85 800, 1000, 1200, 1600 38491.00 NW20H1 65 65 65 1000, 1200, 1600, 2000 32759.00 NW20H2 85 85 85 1000, 1200, 1600, 2000 44339.00 NW20H3 100 100 85 1000, 1200, 1600, 2000 48084.00 NW32H1 65 65 65 1600, 2000, 2500, 3000, 3200 55343.00 NW32H2 85 85 85 1600, 2000, 2500, 3000, 3200 70536.00 NW32H3 100 100 85 1600, 2000, 2500, 3000, 3200 79000.00 NW40H2 85 85 85 2000, 2500, 3000, 3200, 4000 93440.00 NW40H3 100 100 85 2000, 2500, 3000, 3200, 4000 104652.00 NW50H2 85 85 85 2500, 3000, 3200, 4000, 5000 109528.00 NW50H3 100 100 85 2500, 3000, 3200, 4000, 5000 122907.00 i j When used in conjunction with an overcurrent relay, circuit breaker, or fuse. Includes sensor plug. ArcBlok Cradle Please contact your nearest Square D/Schneider Electric sales office for assistance in building a complete circuit breaker or switch catalog number. Table 12: Frame Rating (A) Includes sensor plug. Table 10: Frame Rating (A) ArcBlok W- and Y-Frame Drawout Non-Automatic Switch Model Number Interrupting Rating (kA)a 254 V 508 V 635 V Short-Time Rating (kA RMS) $ Price b 1600 3-Pole W-Frame 800 NW08HA 65 65 65 65 17183.00 1600 NW16HA 65 65 65 65 27775.00 2000 NW20HA 65 65 65 65 32759.00 3200 NW32HA 65 65 65 65 55343.00 2000 3200 Y-Frame 4000 NW40HA 85 85 85 85 93440.00 5000 NW50HA 85 85 85 85 109738.00 5000 © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Model Number Circuit Breaker Switch Interrupting Rating / Withstand Rating (kA) 254 V 508 V 635 V $ Price 3-Pole NW08N1 — 42 42 42 4395.00 NW08H1 NW08HA 65 65 65 4395.00 NW08H2 — 85 85 85 4395.00 NW08H3 NW08HF 100 100 85 4395.00 NW16N1 — 42 42 42 4395.00 NW16H1 NW16HA 65 65 65 4395.00 NW16H2 — 85 85 85 4395.00 NW16H3 NW16HF 100 100 85 4395.00 NW20H1 NW20HA 65 65 65 4888.00 NW20H2 — 85 85 85 4888.00 NW20H3 NW20HF 100 100 85 4888.00 NW32H1 NW32HA 65 65 65 11217.00 NW32H2 — 85 85 85 11217.00 NW32H3 NW32HF 100 100 85 11217.00 NW40H2 NW40HA 85 85 85 18637.00 NW40H3 NW40HF 100 100 85 18637.00 NW50H2 NW50HA 85 85 85 33184.00 NW50H3 NW50HF 100 100 85 33184.00 Y-Frame 4000 When used in conjunction with an overcurrent relay, circuit breaker, or fuse. Includes sensor plug. Circuit Breaker/Switch W-Frame 800 g h Model Number 1600 Y-Frame 4000 Arc-Blok W- and Y-Frame Drawout Automatic Switch W-Frame ArcBlok W- and Y-Frame Drawout Circuit Breaker W-Frame 800 Frame Rating (A) Discount Schedule 7 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers UL 489 Rated Basic Block Table 13: Frame Rating (A) T-, W-, and Y-Frame Fixed Circuit Breaker Model Number Interrupting Rating (kA) 240 V 480 V 600 V 50 50 35 Sensor Plug (A) Table 14: 3-Pole 4-Pole T-Frame NT08N 800 1200 1600 NT08H 65 50 50 NT08L1 100 65 — NT08L 200 100 NT12N 50 NT12H 100, 250, 400, 600, 800 8784.00 13172.00 9566.00 14350.00 10418.00 N/A — 11346.00 N/A 50 35 10216.00 15326.00 65 50 50 10786.00 16178.00 NT12L1 100 65 — NT12L 200 100 — NT16N 50 50 35 NT16H 65 50 50 NT16L1 100 65 — NT16L 200 100 — 600, 800, 1000, 1200 800, 1000, 1200, 1600 11384.00 N/A 12018.00 N/A 800 1200 1600 65 65 50 NW08H 100 100 85 NW12N 65 65 50 NW12H 100 100 85 NW16N 65 65 50 NW16H 100 100 85 Model Number Withstand Rating (kA RMS)a 240 V 480 V 600 V Instantaneous Override (kA RMS) $ Priceb 3-Pole 4-Pole 16330.00 T-Frame 800 1200 1600 NT08HF 65 50 50 40 11548.00 NT08HB 200 100 NA 10 13328.00 NT12HF 65 50 50 40 12828.00 NT12HB 200 100 NA 10 14060.00 NT16HF 65 50 50 40 14160.00 NT16HB 200 100 NA 10 15628.00 N/A 18222.00 N/A 20246.00 N/A W-Frame 17412.00 800 NW08HF 100 100 85 40 14970.00 21176.00 12178.00 18266.00 1200 NW12HF 100 100 85 40 16122.00 22898.00 12776.00 N/A 1600 NW16HF 100 100 85 40 17672.00 25226.00 13648.00 N/A 2000 NW20HF 100 100 85 40 20632.00 29664.00 2500 NW25HF 100 100 85 65 35638.00 52174.00 NW30HF 100 100 85 65 44740.00 65826.00 100, 250, 400, 600, 800 11388.00 17082.00 3000 12402.00 18608.00 Y-Frame 600, 800, 1000, 1200 12840.00 19260.00 4000 NW40HF 100 100 85 75 74060.00 110836.00 13554.00 20330.00 5000 NW50HF 100 100 85 75 87022.00 130232.00 800, 1000, 1200, 1600 14312.00 21466.00 6000 NW60HF 100 100 85 75 142294.00 213436.00 15104.00 22656.00 a NW20N 65 65 50 25674.00 100 100 85 1000, 1200, 1600, 2000 17116.00 NW20H 18064.00 27096.00 2500 NW25H 100 100 85 1200, 1600, 2000, 2500 33068.00 49606.00 3000 NW30H 100 100 85 1600, 2000, 2500, 3000 42172.00 63258.00 NW40H 100 100 85 2000, 2500, 3000, 4000 68568.00 114868.00 85 2500, 3000, 4000, 5000 90426.00 130838.00 85 3000, 4000, 5000, 6000 123832.00 179178.00 2000 Frame Rating (A) 11608.00 W-Frame NW08N T-, W-, and Y-Frame Fixed Automatic Switch $ Pricea b The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. Includes sensor plug. Y-Frame 4000 5000 6000 a 8 NW50H NW60H 100 100 100 100 Includes sensor plug. DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers UL 489 Rated Table 15: Frame Rating (A) Model Number Table 16: T-, W-, and Y-Frame Drawout Circuit Breaker Interrupting Rating (kA) 240 V 480 V 600 V Sensor Plug (A) Frame Model Rating Number (A) $ Price 3-Pole 4-Pole T-Frame NT08N 50 50 35 10460.00 15692.00 65 50 50 11304.00 16956.00 NT08L1 100 65 — 12216.00 N/A NT08L 200 100 — 17368.00 N/A NT08LF 200 100 — 18418.00 N/A NT12N 50 50 35 15368.00 23050.00 NT12H 65 50 50 15992.00 23986.00 16640.00 N/A 1200 100, 250, 400, 600, 800 600, 800, 1000, 1200 NT12L1 100 65 — NT12L 200 100 — 24100.00 N/A NT12LF 200 100 — 25150.00 N/A 65 65 50 12560.00 18840.00 13572.00 20358.00 19296.00 N/A 800 1200 NW08N 800 1200 1600 NW08H 100 100 NW08L 200 150 NW08LF 200 150 NW12N 65 65 85 100, 250, 400, 600, 100 800 100 50 20346.00 N/A 17768.00 26652.00 NW12H 100 100 27734.00 200 150 85 600, 800, 100 1000, 1200 18488.00 NW12L 26778.00 N/A NW12LF 200 150 100 27828.00 N/A NW16N 65 65 50 20190.00 30284.00 NW16H 100 100 20992.00 31488.00 NW16L 200 150 85 800, 1000, 100 1200, 1600 35416.00 N/A NW16LF 200 150 100 36466.00 N/A 50 1200 1600 NW20N 65 65 NW20H 100 100 24124.00 36188.00 27214.00 40820.00 40966.00 N/A NW20L 200 150 85 1000, 1200, 100 1600, 2000 NW20LF 200 150 100 42016.00 N/A NW25H 100 100 85 1200, 1600, 100 2000, 2500 36740.00 55110.00 47940.00 N/A 85 1600, 2000, 100 2500, 3000 48176.00 72264.00 68892.00 N/A 2000 2500 3000 240 V 480 V 600 V Instantaneous Override (kA RMS) $ Price 3-Pole 4-Pole 19096.00 NW25L 200 150 NW30H 100 100 NW30L 200 150 NT08HF 65 50 50 40 13444.00 NT08HB 200 100 NA 10 19508.00 N/A NT12HF 65 50 50 40 18214.00 29118.00 NT12HB 200 100 NA 10 26322.00 N/A 22926.00 W-Frame W-Frame 800 Withstand Rating (kA RMS) T-Frame NT08H 800 T-, W-, and Y-Frame Drawout Automatic Switch 2000 2500 3000 NW08HF 100 100 85 40 16140.00 NW08HB 200 150 100 35 21864.00 N/A NW12HF 100 100 85 40 21056.00 30304.00 NW12HB 200 150 100 35 29346.00 N/A NW16HF 100 100 85 40 23560.00 34056.00 NW16HB 200 150 100 35 37984.00 N/A NW20HF 100 100 85 40 29782.00 43388.00 NW20HB 200 150 100 35 43534.00 N/A NW25HF 100 100 85 65 39308.00 57678.00 NW25HB 200 150 100 65 50508.00 N/A NW30HF 100 100 85 65 50744.00 74832.00 NW30HB 200 150 100 65 71460.00 N/A Y-Frame 4000 5000 6000 NW40HF 100 100 85 75 NW40HB 200 150 100 75 84000.00 125996.00 NW50HF 100 100 85 75 NW50HB 200 150 100 75 138496.00 NW60HF 100 100 85 75 161390.00 242078.00 NW60HB 200 150 100 75 215888.00 118936.00 N/A 98700.00 148046.00 N/A N/A The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. Includes sensor plug. Y-Frame 4000 5000 6000 NW40H 100 100 NW40L 200 150 NW50H 100 100 NW50L 200 150 NW60H 100 100 NW60L 200 150 85 2000, 2500, 81252.00 121878.00 100 3000, 4000 109690.00 N/A 85 2500, 3000, 92550.00 138822.00 100 4000, 5000 124943.00 N/A 85 3000, 4000, 126742.00 190108.00 100 5000, 6000 171102.00 N/A Includes sensor plug. Tested to show the arc flash hazard risk category as referenced in NFPA70E. © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Discount Schedule 9 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers UL 489 Rated Cradle . Table 17: Frame Rating (A) Circuit Breaker/Cradle Connectors For a complete connector set, order both the “Top” and “Bottom” connector kits. T-, W-, and Y-Frame Circuit Breaker/ Automatic Switch Model Number Interrupting Rating / Withstand Rating (kA) Circuit Breaker Switch 240 V 480 V 600 V NT08N — 50 50 35 NT08H NT08HF 65 50 50 NT08L1 — 100 65 — NT08L NT08HB 200 100 — NT08LF — 200 100 — NT12N — 50 50 35 NT12H NT12HF 65 50 50 NT12L1 — 100 65 — Table 18: $ Price 3-Pole 4-Pole T-, W-, and Y-Frame Fixed and Drawout Frame Rating Connector Location T-Frame 800 1200 NT12L NT12HB 200 100 — NT12LF — 200 100 — 3440.00 5166.00 3718.00 N/A 3718.00 N/A 3440.00 5166.00 3718.00 N/A 3718.00 N/A W-Frame 800 1200 1600 2000 2500 3000 NW08N — 65 65 50 NW08H NW08HF 100 100 85 3822.00 5734.00 NW08L NW08HB 200 150 100 4130.00 N/A NW08LF — 200 150 100 4130.00 N/A NW12N — 65 65 50 NW12H NW12HF 100 100 85 NW12L NW12HB 200 150 NW12LF — 200 150 3822.00 5734.00 100 4130.00 N/A 100 4130.00 N/A 3822.00 5734.00 NW16N — 65 65 50 NW16H NW16HF 100 100 85 NW16L NW16HB 200 150 100 4130.00 N/A NW16LF — 200 150 100 4130.00 N/A NW20N — 65 65 50 NW20H NW20HF 100 100 85 NW20L NW20HB 200 150 NW20LF — 200 150 NW25H NW25HF 100 NW25L NW25HB 200 4248.00 6372.00 100 4590.00 N/A 100 4590.00 N/A 100 85 7892.00 150 100 8156.00 NW30H NW30HF 100 100 85 7892.00 NW30L NW30HB 200 150 100 8156.00 NW40H NW40HF 100 100 85 14348.00 4000 NW40L NW40HB 200 150 100 14826.00 NW50H NW50HF 100 100 85 26730.00 5000 NW50L NW50HB 200 150 100 27626.00 6000 NW60H NW60HF 100 100 85 35990.00 NW60L NW60HB 200 150 100 37194.00 10 Front Connected Flat (FCF) Rear Connected T Horizontal/Vertical (RCTH/RCTV) 800–1200 A 800–1200 A Rear Connected T Vertical (RCTV) + Heat Sink 1600 A Front Connected Flat (FCF) Front Connected T (FCT) 800–2000 A 800–3000 A 800–2000 A Rear Connected T Horizontal/Vertical (RCTH /RCTV) 2500–3000 A 4000–5000 A 6000 A Front Connected Flat (FCF) Front Connected T (FCT) 800–2000 A 4000 A 800–3000 A 4000 A 5000 A 800–2000 A Rear Connected T Horizontal/Vertical (RCTH /RCTV) 2500–3000 A 4000 A 5000 A 21518.00 N/A N/A 4-Pole Top SFCF12 716.00 954.00 Bottom SFCF12 716.00 954.00 Top SRCTV12 408.00 544.00 Bottom SRCTV12 408.00 544.00 Top SRCTV16U 1336.00 1780.00 Bottom SRCTV16U 1336.00 1780.00 1534.00 Top SFCF20FT 1030.00 Bottom SFCF20FB 956.00 1434.00 Top SFCT30 1466.00 2198.00 Bottom SFCT30B 1488.00 2234.00 Top SRCTV20 796.00 1194.00 Bottom SRCTV20 796.00 1194.00 Top SRCTV30 2124.00 3186.00 Bottom SRCTV30 2124.00 3186.00 Top SRCTV50 5410.00 8114.00 Bottom SRCTV50 5410.00 8114.00 Top SRCTV60 14988.00 22480.00 Bottom SRCTV60 14988.00 22480.00 1386.00 W- and Y- Frame Drawout 11836.00 40096.00 3-Pole W- and Y- Frame Fixed N/A Y-Frame Kit $ Price / Circuit Breaker Price Adder T-Frame Fixed and Drawout 11838.00 N/A Kit Catalog Number Rea Connected T Vertical (RCTV) 6000 A Top SFCF20T 926.00 Bottom SFCF20B 868.00 1304.00 Top SFCF40 6252.00 9378.00 Bottom SFCF40 6252.00 9378.00 Top SFCT30 1466.00 2198.00 Bottom SFCT30 1466.00 2198.00 Top SFCT50 7196.00 10796.00 Bottom SFCT50 7196.00 10796.00 Top SRCTV20 796.00 1194.00 Bottom SRCTV20 796.00 1194.00 Top SRCTV30 2124.00 3186.00 Bottom SRCTV30 2124.00 3186.00 Top SRCTV50 5410.00 8114.00 Bottom SRCTV50 5410.00 8114.00 Top SRCTV60 14988.00 22480.00 Bottom SRCTV60 14988.00 22480.00 For a 4-pole connector kit, add the suffix (4) to the kit number (e.g. SFCF20T4). Not available for drawout circuit breakers. 53982.00 N/A DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers UL 489 Rated ArcBlok™ Circuit Breakers Basic Block ArcBlok Cradle Table 19: . Table 21: Frame Rating (A) W- and Y-Frame ArcBlok Circuit Breaker Interrupting Rating (kA) Model Number 240 V 480 V 600 V NW08N 65 65 50 NW08H 100 100 85 NW12N 65 65 50 NW12H 100 100 85 Sensor Plug (A) $ Price 3-Pole Frame Rating (A) W-Frame 800 1200 1600 NW16N 65 65 50 NW16H 100 100 85 100, 250, 400, 600, 800 600, 800, 1000, 1200 800, 1000, 1200, 1600 14444.00 15608.00 65 65 50 100 100 85 2500 NW25H 100 100 85 1200, 1600, 2000, 2500 42251.00 3000 NW30H 100 100 85 1600, 2000, 2500, 3000 55402.00 1000, 1200, 1600, 2000 27743.00 4000 NW40H 100 100 85 2000, 2500, 3000, 4000 93440.00 5000 NW50H 100 100 85 2500, 3000, 4000, 5000 106433.00 Includes sensor plug. Table 20: Frame Rating (A) 240 V 480 V 600 V 3-Pole — 65 65 50 4395.00 NW08HF 100 100 85 4395.00 NW12N — 65 65 50 4395.00 NW12H NW12HF 100 100 85 4395.00 NW16N — 65 65 50 4395.00 NW16H NW16HF 100 100 85 4395.00 NW20N — 65 65 50 4885.00 NW20H NW20HF 100 100 85 4885.00 2500 NW25H NW25HF 100 100 85 9076.00 3000 NW30H NW30HF 100 100 85 9076.00 4000 NW40H NW40HF 100 100 85 16500.00 5000 NW50H NW50HF 100 100 85 30740.00 1200 1600 31296.00 Y-Frame Switch $ Price NW08H 24141.00 NW20H Circuit Breaker Interrupting Rating/ Withstand Rating (kA) NW08N 800 21261.00 NW20N 2000 Model Number W-Frame 20433.00 23219.00 Cradle for W- and Y-Frame ArcBlok Circuit Breaker / Automatic Switch 2000 Y-Frame W- and Y-Frame ArcBlok Automatic Switch Model Number Withstand Rating (kA RMS) 240 V 480 V 600 V Instantaneous Override (kA RMS) $ Price 3-Pole W-Frame 800 NW08HF 100 100 85 40 18561.00 1200 NW12HF 100 100 85 40 24214.00 1600 NW16HF 100 100 85 40 27094.00 2000 NW20HF 100 100 85 40 34249.00 2500 NW25HF 100 100 85 65 45204.00 3000 NW30HF 100 100 85 65 58356.00 4000 NW40HF 100 100 85 75 96600.00 5000 NW50HF 100 100 85 75 113505.00 Y-Frame The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. Includes sensor plug. © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Discount Schedule 11 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers UL 489 Rated DC Circuit Breakers Tested to UL489 Supplement SC Table 22: Fixed and Drawout Circuit Breakers Frame Rating (A) Model Number Interrupting Rating (kA) 500 Vdc (max 600 Vdc unloaded) $ Price Drawout $ Price Fixed Version C Version C1 Version C Version C1 W-Frame, Type N 800 NW08NDC 35 42214.00 42746.00 39824.00 40888.00 1200 NW12NDC 35 42214.00 42746.00 39824.00 40888.00 1600 NW16NDC 35 42214.00 42746.00 39824.00 40888.00 2000 NW20NDC 35 42214.00 42746.00 39824.00 40888.00 2500 NW25NDC 35 56158.00 56690.00 56662.00 57726.00 3000 NW30NDC 35 70100.00 70632.00 73500.00 74564.00 4000 NW40NDC 35 84044.00 84576.00 90338.00 91402.00 W-Frame, Type H 800 NW08HDC 85 46435.00 47021.00 43806.00 44977.00 1200 NW12HDC 85 46435.00 47021.00 43806.00 44977.00 1600 NW16HDC 85 46435.00 47021.00 43806.00 44977.00 2000 NW20HDC 85 46435.00 47021.00 43806.00 44977.00 2500 NW25HDC 85 61774.00 62359.00 62328.00 63499.00 3000 NW30HDC 85 77110.00 77695.00 80850.00 82020.00 4000 NW40HDC 85 92448.00 93034.00 99372.00 100543.00 NOTE: All UL rated DC Masterpact circuit breakers are Version C, 2-pole and Version C1, 3-pole circuit breakers. See catalog 0613CT0501. NOTE: Fixed breaker is provided with connectors for Version C and C1 and there are no optional connectors. Connectors can be rotated from vertical to horizontal. NOTE: Trip Units and Connectors are included in Basic Block Price. NOTE: Most electrical and mechanical accessories are the same as the AC circuit breaker. Table 23: Cradle for DC Drawout Circuit Breakers Frame Rating (A) Model Number Interrupting Rating (kA) 500 Vdc (max 600 Vdc unloaded) $ Price Version C Version C1 W-Frame, Type N 800 NW08NDC 35 11778.00 12842.00 1200 NW12NDC 35 11778.00 12842.00 1600 NW16NDC 35 11778.00 12842.00 2000 NW20NDC 35 11778.00 12842.00 2500 NW25NDC 35 11778.00 12842.00 3000 NW30NDC 35 11778.00 12842.00 4000 NW40NDC 35 11778.00 12842.00 W-Frame, Type H 800 NW08HDC 85 11778.00 12842.00 1200 NW12HDC 85 11778.00 12842.00 1600 NW16HDC 85 11778.00 12842.00 2000 NW20HDC 85 11778.00 12842.00 2500 NW25HDC 85 11778.00 12842.00 3000 NW30HDC 85 11778.00 12842.00 4000 NW40HDC 85 11778.00 12842.00 NOTE: All UL rated DC Masterpact circuit breakers are Version C, 2-pole and Version C1, 3-pole circuit breakers. See catalog 0613CT0501. NOTE: Cradle is provided with connectors for Version C and C1 and there are no optional connectors. Connectors can be rotated from vertical to horizontal. NOTE: Connectors are included in Cradle Price. NOTE: Most electrical and mechanical accessories are the same as the AC cradle. 12 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers IEC 60947-2 Rated Basic Block Table 24: Frame Rating (A) T-, W-, and Y-Frame Fixed Circuit Breaker Model Number Interrupting Rating (kA) 240 V 440 V 690 V Sensor Plug (A) Table 25: $ Price 3-Pole Frame Rating (A) 4-Pole T-Frame 800 1000 1250 1600 NT08H1 42 42 42 NT08H2 50 50 42 NT08L1 150 130 NT10H1 42 NT10H2 1000 1250 1600 2000 2500 3200 4000 5000 6300 Withstand Rating (kA RMS) 240 V 440 V 690 V Instantaneous Override (kA RMS) $ Price 3-Pole 4-Pole 8516.00 11880.00 9468.00 13118.00 800 NW08HF 85 85 85 85 14974.00 19658.00 25 10420.00 14356.00 1000 NW10HF 85 85 85 85 15548.00 20406.00 42 42 9068.00 12600.00 1250 NW12HF 85 85 85 85 16122.00 21154.00 50 50 42 9986.00 13792.00 1600 NW16HF 85 85 85 85 17674.00 23168.00 NT10L1 150 130 25 10904.00 14984.00 2000 NW20HF 85 85 85 85 20632.00 27016.00 NT12H1 42 42 42 9624.00 13322.00 2500 NW25HF 85 85 85 85 35640.00 46524.00 NT12H2 50 50 42 10186.00 14052.00 3200 NW32HF 85 85 85 85 44740.00 58356.00 NT16H1 42 42 42 10748.00 14782.00 4000 NW40HF 85 85 85 85 71556.00 93216.00 NT16H2 50 50 42 11310.00 15512.00 NW08N1 42 42 42 10136.00 14142.00 NW08H1 65 65 65 11388.00 15768.00 NW08H2 100 100 85 12404.00 17090.00 NW10N1 42 42 42 10796.00 15000.00 NW10H1 65 65 65 12114.00 16712.00 NW10H2 100 100 85 12980.00 17838.00 NW12N1 42 42 42 11458.00 15860.00 250, 400, 630, 800 400, 630, 800, 1000 630, 800, 1000, 1250 800, 1000, 1250, 1600 400, 630, 800 400, 630, 800, 1000 630, 800, 1000, 1250 NW12H1 65 65 65 12840.00 17654.00 NW12H2 100 100 85 13554.00 18586.00 NW16N1 42 42 42 12796.00 17598.00 Switches are IEC 60947-3 rated. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. Includes sensor plug. 14310.00 19568.00 15106.00 20598.00 1000, 1250, 1600, 2000 17116.00 23214.00 18064.00 24448.00 1250, 1600, 2000, 2500 29488.00 39298.00 33070.00 43956.00 1600, 2000, 2500, 3200 36670.00 NW16H1 65 65 65 NW16H2 100 100 85 NW20H1 65 65 65 NW20H2 100 100 85 NW25H1 65 65 65 NW25H2 100 100 85 NW32H1 65 65 65 NW32H2 100 100 85 NW40H1 65 65 65 NW40H2 100 100 85 800, 1000, 1250, 1600 2000, 2500, 3200, 4000 NW40bH1 100 100 100 NW40bH2 150 150 100 NW50H1 100 100 100 NW50H2 150 150 100 NW63H1 100 100 100 NW63H2 150 150 100 2000, 2500, 3200, 4000 2500, 3200, 4000, 5000 3200, 4000, 5000, 6300 . Table 26: Frame Rating (A) T-, W-, and Y-Frame Fixed Non-Automatic Switch Model Number Withstand Rating (kA RMS) 240 V 440 V 690 V Short-Time (1s) Rating (kA RMS) $ Price 3-Pole 4-Pole T-Frame 800 NT08HA 42 42 42 42 9370.00 1000 NT10HA 42 42 42 42 9994.00 13804.00 1250 NT12HA 42 42 42 42 10622.00 14616.00 1600 NT16HA 42 42 42 42 11042.00 15164.00 NW08NA 42 42 42 42 11156.00 15464.00 NW08HA 50 50 50 50 12492.00 18284.00 NW10NA 42 42 42 42 11898.00 16432.00 48634.00 NW10HA 50 50 50 50 13326.00 19368.00 42172.00 55788.00 NW12NA 42 42 42 42 12644.00 17400.00 60184.00 79202.00 NW12HA 50 50 50 50 14162.00 20452.00 68988.00 90648.00 NW16NA 42 42 42 42 13144.00 18052.00 NW16HA 50 50 50 50 14722.00 21182.00 2000 NW20HA 50 50 50 50 18516.00 25032.00 2500 NW25HA 50 50 50 50 25758.00 34450.00 3200 NW32HA 50 50 50 50 32368.00 43042.00 4000 NW40HA 50 50 50 50 51790.00 68290.00 Y-Frame 4000 Model Number W-Frame W-Frame 800 W-Frame Fixed Automatic Switch 72565.00 80547.00 87078.00 96657.00 90426.00 100328.00 108628.00 121068.00 121718.00 135536.00 156020.00 173460.00 Includes sensor plug. 12990.00 W-Frame 800 1000 1250 1600 Y-Frame 4000 NW40bHA 85 85 85 85 65956.00 86707.00 5000 NW50HA 85 85 85 85 80122.00 105124.00 6300 NW63HA 85 85 85 85 117038.00 153112.00 Switches are IEC 60947-3 rated. Includes sensor plug. When used in conjunction with an overcurrent relay, circuit breaker, or fuse. 0.5s for T-frame. © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Discount Schedule 13 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers IEC 60947-2 Rated Table 27: Frame Rating (A) T-, W-, and Y-Frame Drawout Circuit Breaker Model Number Interrupting Rating (kA) 240 V 440 V 690 V 1150 V Sensor Plug (A) Table 28: $ Price 3-Pole 4-Pole T-Frame 800 1000 1250 1600 NT08H1 42 42 42 — NT08H2 50 50 42 — NT08L1 150 130 25 — NT10H1 42 42 42 — NT10H2 50 50 42 — NT10L1 150 130 25 — NT12H1 42 42 42 — NT12H2 50 50 42 — NT16H1 42 42 42 — NT16H2 50 50 42 — Frame Rating (A) 1000 1250 1600 2000 2500 3200 4000 5000 6300 $ Price 3-Pole 4-Pole 9928.00 13772.00 15608.00 800 NW08HF 85 85 85 — 85 16010.00 21006.00 15790.00 21390.00 1000 NW10HF 85 85 85 — 85 17892.00 23452.00 11322.00 17444.00 1250 NW12HF 85 85 85 — 85 21170.00 27712.00 12756.00 19596.00 1600 NW16HF 85 85 85 — 85 23804.00 31136.00 17718.00 24026.00 2000 NW20HF 85 85 85 — 85 30142.00 39376.00 630, 800, 1000, 1250 14192.00 21750.00 2500 NW25HF 85 85 85 — 85 39486.00 51524.00 15184.00 22026.00 3200 NW32HF 85 85 85 — 85 51492.00 67132.00 800, 1000, 1250, 1600 16176.00 22302.00 17168.00 22578.00 4000 NW40HF 85 85 85 — 85 82436.00 107360.00 11032.00 15302.00 12732.00 17060.00 13742.00 18438.00 17544.00 23768.00 400, 630, 800, 1000 Switches are IEC 60947-3 rated. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. Includes sensor plug. NW08N1 42 42 42 — NW08H1 65 65 65 — NW08H2 100 100 85 — NW08L1 150 150 100 — NW08H10 — — — 50 14916.00 19972.00 NW10N1 42 42 42 — 12580.00 17418.00 NW10H1 65 65 65 — 14434.00 19384.00 NW10H2 100 100 85 — 15534.00 20884.00 NW10L1 150 150 100 — 19686.00 26696.00 NW10H10 — — — 50 16618.00 22294.00 NW12N1 42 42 42 — 15768.00 21770.00 17938.00 24166.00 18716.00 25144.00 24344.00 33052.00 400, 630, 800 400, 630, 800, 1000 NW12H1 65 65 65 — NW12H2 100 100 85 — NW12L1 150 150 100 — NW12H10 — — — 50 20122.00 27078.00 630, 800, 1000, 1250 Table 29: Frame Rating (A) T-, W-, and Y-Frame Drawout Non-Automatic Switch Model Number Withstand Rating (kA RMS) Short-Time (1s) Rating 240 V 440 V 690 V 1150 V (kA RMS)r $ Price 3-Pole 4-Pole T-Frame 800 NT08HA 42 42 42 — 42 10054.00 13940.00 1000 NT10HA 42 42 42 — 42 12466.00 17069.00 1250 NT12HA 42 42 42 — 42 14872.00 20200.00 1600 NT16HA 42 42 42 — 42 15352.00 20822.00 NW08NA 42 42 42 — 42 11172.00 15488.00 NW08HA 50 50 50 — 50 12512.00 18310.00 NW08HA10 — — — 50 50 14696.00 22184.00 NW10NA 42 42 42 — 42 13850.00 18966.00 NW10HA 50 50 50 — 50 15510.00 22206.00 NW10HA10 — — — 50 50 17694.00 26080.00 NW12NA 42 42 42 — 42 16524.00 22444.00 NW12HA 50 50 50 — 50 18508.00 26104.00 W-Frame NW16N1 42 42 42 — 17974.00 24780.00 NW16H1 65 65 65 — 20362.00 27474.00 NW16H2 100 100 85 — 21164.00 28568.00 NW16L1 150 150 100 — 32198.00 43772.00 NW16H10 — — — 50 22546.00 30384.00 NW20H1 65 65 65 — 24684.00 32594.00 NW20H2 100 100 85 — 27770.00 36806.00 NW20H3 150 150 100 — 29802.00 39498.00 NW20L1 150 150 100 — 37242.00 49884.00 NW20H10 — — — 50 26868.00 35504.00 NW12HA10 — — — 50 50 20692.00 29978.00 NW25H1 65 65 65 — 33318.00 44276.00 NW16NA 42 42 42 — 42 17056.00 23136.00 NW25H2 100 100 85 — 36746.00 48956.00 NW16HA 50 50 50 — 50 19104.00 26876.00 NW25H3 150 150 100 — 39902.00 52836.00 NW16HA10 — — — 50 50 21288.00 30750.00 NW25H10 — — — 50 35502.00 47188.00 NW20HA 50 50 50 — 50 23186.00 31106.00 NW32H1 65 65 65 — 44752.00 59882.00 NW32H2 100 100 85 — 48180.00 64564.00 NW20HA10 — — — 50 50 20700.00 28906.00 NW32H3 150 150 100 — 52878.00 69710.00 NW25HA 50 50 50 — 50 27402.00 36586.00 NW25HA10 — — — 50 50 29586.00 40460.00 NW32HA 50 50 50 — 50 42530.00 56250.00 NW32HA10 — — — 50 50 44714.00 60126.00 NW40HA 50 50 50 — 50 68046.00 89426.00 NW40HA10 — — — 50 50 70230.00 93300.00 800, 1000, 1250, 1600 1000, 1250, 1600, 2000 1250, 1600, 2000, 2500 1600, 2000, 2500, 3200 NW32H10 — — — 50 46936.00 62792.00 NW40H1 65 65 65 — 74102.00 97300.00 NW40H2 100 100 85 — 79592.00 104792.00 NW40H3 150 150 100 — 86214.00 113046.00 NW40H10 — — — 50 76286.00 100210.00 2000, 2500, 3200, 4000 800 1000 1250 1600 2000 2500 3200 4000 Y-Frame NW40bH1 100 100 100 NW40bH2 150 150 100 NW50H1 100 100 100 NW50H2 150 150 100 NW63H1 100 100 100 NW63H2 150 150 100 — 2000, 2500, 3200, 4000 — 2500, 3200, 4000, 5000 — 3200, 4000, 5000, 6300 82832.00 108509.00 4000 NW40bHA 85 85 85 — 85 75484.00 99613.00 93626.00 122650.00 5000 NW50HA 85 85 85 — 85 80738.00 105926.00 6300 NW63HA 85 85 85 — 85 117938.00 154282.00 91562.00 119996.00 109760.00 144840.00 124008.00 162172.00 157290.00 207604.00 Switches are IEC 60947-3 rated. Includes sensor plug. When used in conjunction with an overcurrent relay, circuit breaker, or fuse. 1000 V for T-frame. Includes sensor plug. 1000 V for T-frame. 14 240 V 440 V 690 V 1150 V Instantaneous Override (kA RMS) 10626.00 250, 400, 630, 800 Y-Frame 4000 Withstand Rating (kA RMS) W-Frame W-Frame 800 Model Number W-Frame Drawout Automatic Switch DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers IEC 60947-2 Rated Cradle Table 30: Frame Rating (A) T-, W-, and Y-Frame Circuit Breaker/Switch Model Number Circuit Breaker/Cradle Connectors $ Price For a complete connector set, order both the “Top” and “Bottom” connector kits. Circuit Breaker Switch NT08H1 NT08H10 NT08HA NT08HA10 3284.00 4274.00 NT08L1 — 3378.00 4396.00 NT10H1 NT10H10 NT10HA NT10HA10 3284.00 4274.00 NT10L1 — 3378.00 4396.00 1250 NT12H1 NT12H10 NT12HA, NT12HA10 3284.00 4274.00 1600 NT16H1 NT16H10 NT16HA, NT16HA10 NW08N1 NW08NA NW08H1 NW08HA 3-Pole 4-Pole T-Frame 800 1000 Table 31: 3284.00 4274.00 W-Frame 800 1000 1250 1600 NW08H2 NW08HF NW08H10 NW08HA10 NW08L1 — NW10N1 NW08NA NW10H1 NW08HA NW10H2 NW08HF NW10H10 NW08HA10 NW10L1 — NW12N1 NW08NA NW12H1 NW08HA NW12H2 NW08HF NW12H10 NW08HA10 NW12L1 — NW16N1 NW08NA NW16H1 NW08HA NW16H2 NW08HF NW16H10 NW08HA10 NW16L1 — NW20H1 2000 2500 3200 4000 3650.00 4748.00 3754.00 4882.00 3650.00 4748.00 3754.00 4882.00 3650.00 3754.00 4748.00 4882.00 3650.00 4748.00 3754.00 4882.00 5000 6300 Front Connected Flat (FCF) 800–1600A Fixed Only Rear Connected T Horizontal/Vertical (RCTH/RCTV) 800–1600A Fixed Only NW20HF NW20H10 NW20HA10 NW20H3 — 3742.00 4864.00 NW20L1 — 3796.00 4932.00 NW25H1 NW25HA NW25H2 NW25HF NW25H10 NW25HA10 NW25H3 — NW32H1 NW32HA NW32H2 NW32HF NW32H10 NW32HA10 NW32H3 — NW40H1 NW40HA NW40H2 NW40HF NW40H10 NW40HA10 NW40H3 — 3690.00 Front Connected Flat (FCF) 800–1600A Drawout Only Rear Connected T Horizontal/Vertical (RCTH/RCTV) 800–1600A Drawout Only NW40bHA NW40bH2 — NW50H1 NW50HA NW50H2 — NW63H1 NW63HA NW63H2 — © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Kit Catalog Number t Kit $ Price/ Circuit Breaker Price Adder 3-Pole 4-Pole Top SFCF16F 1316.00 1756.00 Bottom SFCF16F 1316.00 1756.00 Top SRCTV16 744.00 992.00 Bottom SRCTV16 744.00 992.00 Top SFCF16T 1202.00 1602.00 Bottom SFCF16B 886.00 1182.00 Top SRCTV16 744.00 992.00 Bottom SRCTV16 744.00 992.00 Drawout and Fixed Circuit Breaker Connectors Rea Spreader Adapter 800–1600A Rear T Adapter 800–1600A Rear Flat Adapter 800–1600A Table 32: Top SRSA16 1336.00 1776.00 Bottom SRSA16 1336.00 1776.00 Top SRTA16 2338.00 3110.00 Bottom SRTA16 2338.00 3110.00 Top SRFA16 1336.00 1776.00 Bottom SRFA16 1336.00 1776.00 Location Kit Catalog Number W/Y-Frame Frame Rating 4796.00 Kit $ Price/ Circuit Breaker Price Adder 3-Pole 4-Pole Fixed Circuit Breaker Connectors Front Connected Flat (FCF) 800–3200 A Fixed Only Top SFCF32T 2386.00 3174.00 Bottom SFCF32B 2236.00 2974.00 Top SFCF32 2236.00 2976.00 Bottom SFCF32 2236.00 2976.00 1014.00 Drawout Circuit Breaker Cradle Connectors 7886.00 10126.00 8112.00 10542.00 7886.00 10252.00 8112.00 11626.00 11960.00 10542.00 15112.00 Front Connected Flat (FCF) 800–3200 A Drawout Only Drawout and Fixed Circuit Breaker Connectors Rear Connected T Horizontal/Vertical (RCTH/RCTV) Rear Connected T Horizontal (RCTH) 15540.00 800–3200 A 5000 A 4000 A 4000 A Rear Connected T Vertical (RCTV) NW40bH1 Location Drawout Circuit Breaker Cradle Connectors NW20HA NW20H2 Frame Rating Fixed Circuit Breaker Connectors Connector Y-Frame 4000 Connector T-Frame 19839.00 25786.00 27718.00 36032.00 38724.00 50342.00 DE2F Discount Schedule 6300 A Top SRCTV32 762.00 Bottom SRCTV32 762.00 1014.00 Top SRCTV50E 2864.00 3810.00 Bottom SRCTV50E 2864.00 3810.00 Top SRCTH40 1414.00 1880.00 Bottom SRCTH40 1414.00 1880.00 Top SRCTV40 2178.00 2896.00 Bottom SRCTV40 2178.00 2896.00 Top SRCTV63 4462.00 5936.00 Bottom SRCTV63 4462.00 5936.00 For a 4-pole connector kit, add (4) to the end of the catalog number (e.g. SFCF32T4). NW40b circuit breakers use 5000 A connectors. 15 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers IEC 60947-2 Rated DC Circuit Breakers and Non-Automatic Switches IEC 60947-2 Rated (DC Circuit Breakers) Tested to IEC 60947 Standards IEC 60947-2 Rated (DC Circuit Breakers) Table 35: Table 33: Frame Rating (A) Frame Rating (A) Fixed and Drawout Circuit Breakers Model Number KA for Connection U = Icu 500 Vdc - L/R Version ≤ 15 ms $ Price Fixed $ Price Drawout Cradle (DC Products) Model Number Connection Version Icu KA for U = 500 Vdc - L/R ≤ 15 ms $ Price W-Frame Type N W- Frame 1000 NW10NDC C 35 11508.00 Type N 2000 NW20NDC C 35 11508.00 4000 NW40NDC C 35 11508.00 1000 NW10HDC C 85 11508.00 1000 NW10HDC D 85 12314.00 1000 NW10HDC E 85 13920.00 2000 NW20HDC C 85 11508.00 2000 NW20HDC D 85 12314.00 2000 NW20HDC E 85 13920.00 4000 NW40HDC C 85 11508.00 4000 NW40HDC D 85 12314.00 4000 NW40HDC E 85 13920.00 1000 NW10NDC C 35 38376.00 36204.00 2000 NW20NDC C 35 38376.00 36204.00 4000 NW40NDC C 35 76404.00 82126.00 Type H Type H 1000 NW10HDC C 85 41260.00 38920.00 1000 NW10HDC D 85 44132.00 41634.00 1000 NW10HDC E 85 49890.00 47064.00 2000 NW20HDC C 85 41260.00 38920.00 2000 NW20HDC D 85 44132.00 41634.00 2000 NW20HDC E 85 49890.00 47064.00 4000 NW40HDC C 85 82134.00 88300.00 4000 NW40HDC D 85 87864.00 94450.00 4000 NW40HDC E 85 99324.00 106764.00 NOTE: IEC rated DC Masterpact (H rated) can have connectors version C, D or E, 3-pole circuit breakers. See catalog 0613CT0501. NOTE: IEC rated DC Masterpact (H rated) can have connectors version C, D or E, 3-pole circuit breakers. See catalog 0613CT0501. NOTE: Connectors are included in cradle price NOTE: Most electrical and mechanical accessories are the same as the AC cradle. NOTE: Trip units and connectors are included in the circuit breaker price NOTE: Most electrical and mechanical accessories are the same as the AC circuit breaker. IEC 60947-3 Rated (DC Non-Automatic Switch) Table 34: Table 36: Fixed and Drawout Non-Automatic Switch Frame Rating Model Number (A) Connection Version Icw KA for U = 500 Vdc $ Price Fixed IEC 60947-3 Rated (DC Non-Automatic Switch) Model Number Connection Version Icw KA for U = 500 Vdc 1000 NW10HADC C 85 11508.00 1000 NW10HADC D 85 12314.00 1000 NW10HADC E 85 13920.00 2000 NW20HADC C 85 11508.00 2000 NW20HADC D 85 12314.00 2000 NW20HADC E 85 13920.00 4000 NW40HADC C 85 11508.00 4000 NW40HADC D 85 12314.00 4000 NW40HADC E 85 13920.00 Frame Rating (A) $ Price Drawout Cradle (DC Products) $ Price W- Frame Type HA W- Frame Type HA 1000 NW10HADC C 85 33008.00 31136.00 1000 NW10HADC D 85 35306.00 33308.00 1000 NW10HADC E 85 39912.00 37652.00 2000 NW20HADC C 85 33008.00 31136.00 2000 NW20HADC D 85 35306.00 33308.00 2000 NW20HADC E 85 39912.00 37652.00 4000 NW40HADC C 85 65708.00 70640.00 4000 NW40HADC D 85 70292.00 75560.00 4000 NW40HADC E 85 79460.00 85412.00 NOTE: IEC rated DC Masterpact non-automatic switches (HA rated) can have connectors version C, D or E, 3-pole non-automatic switch. See catalog 0613CT0501. NOTE: IEC rated DC Masterpact (HA rated) can have connectors version C, D or E, 3-pole non-automatic switch. See catalog 0613CT0501. NOTE: Connectors are included in cradle price. NOTE: Most electrical and mechanical accessories are the same as the AC cradle. NOTE: Connectors are included in breaker or switch price. NOTE: Most electrical and mechanical accessories are the same as the AC circuit breakers. 16 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Trip Unit and Options Table 37: Trip Unit Model Protection 2.0 (IEC only) Additional Features Field-Installable $ Kit Price/ Catalog Circuit Breaker Number Price Adder LS0 3.0 (UL/ANSI only) LI 5.0 LSI 2.0A (IEC only) LS0 3.0A (UL/ANSI only) LI 5.0A LSI 6.0A LSIG 5.0P LSI 6.0P LSIG 5.0H LSI 6.0H LSIG None S132R 2920.00 S131A 2920.00 S133A 4176.00 Table 39: Trip Unit Options S142R 4554.00 S141A 4554.00 S143A 5812.00 CT Characterization 4410.00 S144A 7418.00 Automatic Reset 658.00 Ammeter Metering, Advanced Protection S163A 8720.00 S164A 10324.00 Metering, Advanced Protection & Harmonic Analysis S173A 14770.00 S174A 16374.00 Circuit Breaker $ Price Adder Description Available as factory-installed circuit breaker option only. See the Class 0613 catalog, Masterpact Low-Voltage Power Circuit Breakers for details. Table 40: The standard rating plug supplied with a trip unit will be the “A” rating plug. To specify an alternative adjustable rating plug, please add the letter designation to the end of the catalog number. Please refer to following table for a complete listing of adjustable settings available with each plug. (Example: S143B would specify a “B” rating plug instead of the standard "A" plug.) Use suffix “N” if no rating plug is required, deduct $200. from the complete trip unit kit price. Requires circuit breaker Communications Module. When replacing a basic trip unit with type A (Ammeter), P (Power metering) or H (Harmonic analysis) trip unit, order the 12-pin connector kit S33101, price $228. Table 38: A Zone-Selective Interlocking (ZSI) system with/without MDGF/SGR may require a Restraint Interface Module (RIM), catalog number S48890 (120 Vac/24 Vdc) or S48895 (240 Vac/24 Vdc). Price: $2480. See the Masterpact NT/NW Universal Power Circuit Breaker catalog (0613CT0001) for details. Circuit Breaker Communications Module Communications Type Catalog Number Fixed Drawout Kit $ Price / Circuit Breaker Price Adder NW MODBUS® S47405 S48384 2470.00 NT MODBUS S48188 S47485 2470.00 NOTE: Standard for “P” trip unit; optional for “A” trip unit. Trip Unit Adjustable Rating Plug Field-Installable Kit Standard Options Settings (Tolerance:1.05–1.2) Trip Unit Catalog $ Price Character Number 5 Plug “A” Plug “B” Plug “C” Plug “D” UL/ANSI Plug “E” .4 - .45 - .50 - .60 - .63 - .7 - .8 - .9 - 1 .4 - .44 - .50 - .56 - .63 - .75 - .88 - .95 - 1 .42 - .50 - .53 - .58 - .67 - .75 - .83 - .95 - 1 .4 - .48 - .64 - .7 - .8 - .9 - .93 - .95 - 1 .60 - .70 - .75 - .80 - .85 - .90 - .93 - .95 - 1 A B C D E S48818 S48819 S48820 S48836 S48837 200.00 Plug “F” Plug “G” Plug “H” .84 - .86 - .88 - .9 - .92 - .94 - .96 - .98 - 1 .66 - .68 - .7 - .72 - .74 - .76 - .78 - .8 - .82 .48 - .5 - .52 - .54 - .56 - .58 - .6 - .62 - .64 F G H S48838 S48839 S48840 Standard Lower Range Upper Range OFF .4 - .5 - .6 - .7 - .8 - .9 - .95 - .98 - 1 .4 - .45 - .5 - .55 - .6 - .65 - .7 - .75 - .8 .8 - .82 - .85 - .88 - .9 - .92 - .95 - .98 - 1 No long time protection R S T P S33542 S33543 200.00 S33544 S33545 IEC Standard offer. For replacement only; rating plug included in price of trip unit. © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Discount Schedule 17 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Trip Unit and Options Neutral Sensor Table 41: T-Frame Circuit Breakers External neutral sensor for 3-phase, 4-wire residual ground fault system (or for neutral current monitoring). NT Circuit Breaker Sensor Plug External Neutral Sensor for general use External Neutral Sensor for use in Square D™ Panelboards External Neutral Sensor for use in Square D Switchboards $ Price External neutral sensor for circuit breakers with standard neutral protection 100–250 A S33575 S33924 S33926 400–1600 A S33576 S33925 S33927 S33926 1914.00 External neutral sensor for circuit breakers with oversized neutral protection 100 A S33575 S33924 250 A N/A N/A N/A S33576 S33925 S33927 400–1000 A 1914.00 1200/1250 A S48896 N/A NA 2044.00 1600 A S48182 N/A NA 2208.00 Oversized neutral protection = 1.6 Ir where Ir = long time pick-up. Table 42: W/Y-Frame Circuit Breakers External neutral sensor for 3-phase, 4-wire residual ground fault system (or for neutral current monitoring) and external sensor for Modified Differential Ground Fault (MDGF) or Source Ground Return (SGR) system. PZ4 External Neutral Sensor (For use in PZ4 Switchgear) External Neutral Sensor Frame Sensor Plug (A) 100 250 For Residual Ground Fault $ Price For 3-Pole Circuit Breaker with Oversize Neutral Protection S48916 S48916 N/A For Residual Ground Fault $ Price 2014.00 — $ Price For 3-Pole Circuit Breaker with Oversize Neutral Protection S48902 S48902 N/A $ Price MDGF/ SGR Sensor $ Price 3168.00 — 400 600/630 800 1000 W 2014.00 S34036 2014.00 S34036 3168.00 S48903 3168.00 S48903 1200/1250 S48896 2044.00 S48182 2208.00 S33579 1600 2000 S48896 2044.00 S48182 2208.00 2500 3000 3200 N/A N/A — S48182 — 4000 N/A 2000 S48898 2500 3000 Y 3200 4000 S48897 S48897 4426.00 S48898 4584.00 S33579 N/A N/A — S48897 6300 N/A 4584.00 4426.00 5000 6000 570.00 570.00 — — N/A Kit includes qty. (2) neutral sensors. Four MDGF sensors (phase + 1 neutral) are required for W-frame; eight MDGF sensors are required for Y-frame. For SGR system only one sensor (neutral) is required for W-frame; two sensors for Y-Frame. A MDGF/SGR ground-fault interface module (Cat. no. S48891) is also required for each circuit breaker. Price: $2688. Oversized neutral protection = 1.6 Ir where Ir = long time pick-up. These neutral sensors include their wiring harness. To order this harness as a spare part (cat. no. NCTWIRING) the Price is $204. 18 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Accessories Each electrical accessory kit includes the necessary push-in secondary disconnects for a drawout circuit breaker. Table 44: Table 43: Sensor Plug Lowest possible sensor plug is 50% of frame rating except for the 100 A and 250 A plug Rating (A) Catalog Number Rating (A) Catalog Number 100 S47051 1000 S33093 250 $ Price $ Price Rating (A) Catalog Number 3000 S48825 3200 S33984 S47052 1200 S48824 — — — — 400 S47053 1250 S33094 — — 600 S48823 1600 S33095 — — 630 S33091 2000 S33982 — — 800 S33092 2500 S33983 — — 1040.00 4000 1040.00 Special Y-Frame Sensor Plug Rating (A) Catalog Number 2000 S47821 2500 S47822 3000 S48826 3200 S47823 4000 S47824 5000 S47825 6000 S48827 6300 S47826 $ Price S47820 1040.00 $ Pricea 1040.00 Included in basic block price. Cannot be installed into a circuit breaker with original sensor plug higher than 250 A. Likewise a circuit breaker with original sensor plug of 100 A or 250 A cannot be replaced with a sensor plug higher than 250 A. IEC and ANSI W-frame. Table 45: Auxiliary and Alarm Contacts, Programmable Contact Module, Electrical Close Pushbutton T-Frame Description Fixed Drawout 1a/1b Form C Auxiliary Contact S47042 S47043 Low Level 1a/1b Form C Auxiliary Contact S47339 S33806 4a/4b Form C Auxiliary Contact (OF) — — 4a/4b Form C Auxiliary Contact (OF) with Actuator — — 1a/1b Form C Second Trip Alarm Contact (SDE2) S47340 S47430 Low Level 1a/1b Form C Second Trip Alarm Contact S47341 1a/1b Form C Ready-to-Close Contact (PF) W- & Y-Frame $ Price Fixed Drawout $ Price 136.00 — — — 170.00 — — — — S48198 S48468 546.00 — S48859 S48860 630.00 136.00 S48200 S48475 136.00 S47431 170.00 S48201 S48476 170.00 S47342 S47432 470.00 S47342 S48469 470.00 Low Level 1a/1b Form C Ready-to-Close Contact S47343 S47433 504.00 S47343 S48470 504.00 2 Programmable Contact Module (M2C) S47403 S47483 966.00 S47403 S48382 966.00 6 Programmable Contact Module (M6C) S47404 S47484 1470.00 S47404 S48383 1470.00 Electrical Close Pushbutton (BPFE) S47512 S47512 1208.00 S48534 1208.00 Standard on circuit breaker, information for replacement purposes only. 4a/4b standard on circuit breaker, information for replacement purpose only. Incompatible with remote reset switch (RES). Type P or H trip unit required. Table 46: Voltage 50/60 Hz Shunt Trip, Second Shunt Trip , and Shunt Close T-, W-, & Y-Frame Fixed T-Frame Drawout W- & Y-Frame Drawout 12 dc S47359 S33809 S48490 24–30 ac/dc S47360 S33810 S48491 48–60 ac/dc S47361 S33811 S48492 100–130 ac/dc S47362 S33812 S48493 200–240 ac/dc S47363 S33813 277 ac S47364 S47365 380–480 ac Table 47: $ Price Voltage 50/60 Hz Shunt Trip and Shunt Close for Circuit Breaker with Communication T-, W-, & Y-Frame Fixed T-Frame Drawout W- & Y-Frame Drawout 12 dc S47320 S33791 S48457 24–30 ac/dc S47321 S33792 S48458 48–60 ac/dc S47322 S33793 S48459 S48494 100–130 ac/dc S47323 S33794 S48460 S33814 S48495 200–240 ac/dc S47324 S33795 S48461 S33815 S48496 277 ac S47325 S33796 S48462 380–480 ac S47326 S33797 S48463 666.00 Incompatible with undervoltage coil. Table 48: Voltage $ Price 666.00 Undervoltage Trip T-, W-, & Y-Frame Fixed T-Frame Drawout W- & Y-Frame Drawout S48501 $ Price Instantaneous UV Trip (MN) 24–30 ac/dc S47380 S33819 48–60 ac/dc S47381 S33820 S48502 100–130 ac/dc S47382 S33821 S48503 200–240 ac/dc S47383 S33822 S48504 380–480 ac S47385 S33824 S48506 1054.00 Adjustable Time Delay Module © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 DE2F Discount Schedule 19 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Accessories Table 49: Spring Charging Motor (MCH) T-Frame Voltage Fixed $ Price Drawout Cradle Accessories W- & Y-Frame Fixed Drawout $ Price Table 53: AC 48 S47391 S47461 S48207 S48522 100–130 S47395 S47465 S48211 S48526 200–240 S47396 S47466 S48212 S48527 277 S47398 S47468 S48213 S48528 380–415 S47398 S47468 S48214 S48529 440–480 S47400 S47470 S48215 S48530 3580.00 3734.00 Cradle Communications Module Communications Type Catalog Number MODBUS S48377 Table 54: $ Price 2002.00 ANSI C37/UL 1066/UL 489 Cradle Safety Shutter, Secondary Disconnects Terminal Shield Description 3-Pole $ Price 4-Pole $ Price T-Frame DC 24–30 S47390 S47460 S48206 S48521 Safety Shutter S48933 342.00 S48934 444.00 48–60 S47391 S47461 S48207 S48522 Secondary Disconnects Terminal Shield S33763 220.00 S33764 274.00 100–130 S47392 S47462 S48208 S48523 200–250 S47393 S47463 S48209 S48524 Safety Shutter S65346 680.00 S65347 908.00 Shutter Padlock Provision S65350 201.00 S65350 201.00 Secondary Disconnects Terminal Shield S48595 296.00 S48596 394.00 Safety Shutter S65348 1162.00 S65349 1548.00 Shutter Padlock Provision S65350 201.00 S65350 201.00 Secondary Disconnects Terminal Shield S48597 376.00 S48598 502.00 Table 50: 3580.00 3734.00 Remote Reset (RES) T-Frame Voltage Fixed 110–130 S47344 S47434 200–240 S47345 S47435 Y-Frame W- & Y-Frame $ Price Drawout Fixed 844.00 W-Frame Drawout S48202 S48472 S48203 S48473 $ Price 844.00 Incompatible with extra trip alarm switch (SDE2). Table 55: Table 51: Circuit Breaker Locking Options One Lock Description $ Price T-Frame W/Y-Frame Kirk Key Lock + Provision S48939 S48945 Two Locks (W/Y-Frame only) Description $ Price Identical Different 2546.00 S48946 S48947 4092.00 Schneider Electric Lock + Provision S48942 Provision for Kirk / Schneider Electric Lock S47517 Ronis Key Lock + Provision S47521 S48549 3310.00 S48550 S48551 5322.00 Profalux Key Lock + Provision S47519 S48545 3310.00 S48546 S48547 5322.00 Provision for Ronis Lock S47516 908.00 — — Provision for Profalux Lock S47515 S48541 908.00 — — — Provision for Castell Lock S47518 S48543 908.00 — — — Padlock Attachment S47514 S48539 256.00 — — — Padlockable Open/Close Push Button Cover S33897 S48536 186.00 — — — S48948 S48542 S48541 2314.00 S48949 S48950 908.00 — — IEC 60947-2 Cradle Safety Shutter, Secondary Disconnects Terminal Shield 3722.00 — — Can fit up to two locks. To order Kirk Key or Schneider Electric locks, please fill out the keylock order form from page 26. 3-Pole $ Price 4-Pole $ Price T-Frame Safety Shutter S33765 342.00 S33766 444.00 Secondary Disconnects Terminal Shield S33763 220.00 S33764 274.00 W-Frame Safety Shutter S48587 680.00 S48589 908.00 Shutter Padlock Provision S48591 100.00 S48591 100.00 Secondary Disconnects Terminal Shield S48595 296.00 S48596 394.00 Y-Frame Safety Shutter S48588 1162.00 S48590 1548.00 Shutter Padlock Provision S48591 100.00 S48591 100.00 Secondary Disconnects Terminal Shield S48597 376.00 S48598 502.00 Includes padlock provision. 2 required. Table 56: Cradle Position Switches (Cell Switches) Catalog Number Description $ Price T-, W-, and Y-Frame 1a/1b Form C Connected/Test/Disconnected Switch S33170 148.00 Low Level 1a/1b Form C Connected/Test/Disconnected Switch S33171 216.00 1a Connected/Test/Disconnected Switch (Ring Tongue) S48929 84.00 1b Connected/Test/Disconnected Switch (Ring Tongue) S48930 84.00 Set of 3 Cell Switch Actuating Arms S48560 48.00 W- and Y-Frame Table 52: Miscellaneous Circuit Breaker Accessories Description T-Frame $ Price W- & Y-Frame $ Price Mechanical Operation Counter S33895 920.00 S48535 920.00 Door Escutcheon for Fixed Circuit Breaker S33718 176.00 S48601 176.00 A set of 3 actuating arms is standard on the cradle. One actuating arm can operate up to 3 switches. For replacement only, door escutcheon included with circuit breaker. 20 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Accessories Table 57: Table 59: Cradle Cell Keying and Cradle Position Locking Description Cell Keying Kit (all pins the same length) Cell Keying Kit for W/Y-frame (pins of varying lengths) All production after December 2012 T-Frame W/Y-Frame $ Price S33767 S48562 96.00 — NWCELLKEY 176.00 Cradle Metering CT Kit (set of 3) For use with UL and ANSI rated circuit breakers only. Sensor Plug (A) Catalog Number 250 SMCT250 1372.00 400 SMCT400 1372.00 600 SMCT600 1380.00 800 SMCT800 1410.00 1200 SMCT1200 1476.00 1600 SMCT1600 1548.00 2000 SMCT2000 2412.00 2000 SMCT2000R 2020.00 W-Frame Key Locks—Kirk/Schneider Electric 1 Kirk Lock S48917 S48923 2154.00 2 Identical Kirk Locks S48918 S48924 3312.00 2 Different Kirk Locks S48919 S48925 3312.00 1 Schneider Electric Lock S48920 S48926 1960.00 2 Identical Schneider Electric Locks S48921 S48927 3012.00 2 Different Schneider Electric Locks S48922 S48928 3012.00 Provision for 2 Kirk/Schneider Electric Locks S33936 S48565 908.00 Provision for 1 Kirk/Schneider Electric Lock S33772 — 908.00 S33776 S48572 2802.00 2 Identical Ronis Locks S33777 S48573 4306.00 2 Different Ronis Locks S33778 S48574 4306.00 1 Profalux Lock S33773 S48568 2802.00 2 Identical Profalux Locks S33774 S48569 4306.00 2 Different Profalux Locks S33775 S48570 4306.00 Provision for 2 Ronis Locks S33770 S48564 908.00 Provision for 2 Profalux Locks S33769 S48564 908.00 Provision for 2 Castell Locks S33771 S48566 908.00 Includes mounting provision. To order Kirk Key or Schneider Electric locks, please fill out the keylock order form from page 26. Table 58: Masterpact NW/NT Circuit Breaker Remote Racking Description Masterpact NW/NT Remote Racking Device 2500 SMCT2500R 2110.00 3000 SMCT3000R 2258.00 3200 SMCT3200R 2452.00 2000 SMCT2000Y 2552.00 2500 SMCT2500Y 2712.00 3000 SMCT3000Y 2868.00 3200 SMCT3200Y 2940.00 4000 SMCT4000Y 3326.00 5000 SMCT5000Y 3656.00 6000 SMCT6000Y 4080.00 Y-Frame Key Locks—Ronis/Profalux 1 Ronis Lock Cat. No. $ Price For NW20L1/NW20L circuit breaker. Table 60: Cradle Miscellaneous Accessories Description 330.00 Racking Interlock Kit (IBPO) S33788 238.00 S48582 238.00 Door Escutcheon S33857 370.00 685980 370.00 Transparent Cover S33859 1290.00 685981 1290.00 — S48477 264.00 — 21,500.00 Combined “Connected” and “Closed” Switch (1a/1b EF Switch) Masterpact NT Remote Racking Device NTMPRRT 21,500.00 Low Level EF Switch Mounting Bracket Kit for NT Remote Racking (contains 10 mounting brackets) S47104 215.00 Control Unit for NW Remote Racking S47101 3650.00 30 ft Control Cable for NW Remote Racking S47102 620.00 Drive Shaft for NW Remote Racking S47103 290.00 Drive Shaft for NT Remote Racking S47103 290.00 N/A S48478 542.00 Cable Door Interlock for Drawout Circuit Breakers S33921 2584.00 S48614 2584.00 Cable Door Interlock for Fixed Circuit Breakers N/A S33920 2584.00 S48614 2584.00 For replacement only, door escutcheon included with circuit breaker. For Automatic Spring Discharge (DAE) for IEC drawout circuit breakers, add $586.00. For Off-Button-Crank Interface (IBPO) function for IEC drawout circuit breakers, add $586.00. Table 61: Unit comes with 10 mounting brackets included. For replacement only. Spare Parts for ArcBlok™ UL/ANSI Masterpact NW Circuit Breakers, Switches, and Cradles Description DE2F $ Price S48579 32,000.00 215.00 W/Y-Frame 330.00 NWMPRRT S47100 $ Price S33786 NWNTMPRRT Mounting Bracket Kit for NW Remote Racking (contains 10 mounting brackets) T-Frame Door Interlock Kit (VPEC) Masterpact NW Remote Racking Device © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 $ Price Cat. No. $ Price ArcBlok Shields 65251 92.00 UL/ANSI ArcBlok 2 Cluster Support 65253 577.00 UL/ANSI ArcBlok 3 Cluster Support 65254 577.00 UL/ANSI ArcBlok 4 Cluster Support 65255 577.00 UL/ANSI ArcBlok 6 Cluster Support 65256 577.00 UL/ANSI ArcBlok 10 Cluster Support 65257 577.00 ArcBlok Prepared Space Cassette (W-Frame) 65252 17183.00 ArcBlok Prepared Space Cassette (Y-Frame) 65263 34367.00 Discount Schedule 21 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Accessories Table 62: Secondary Disconnects Wiring Kit Fixed Type T-, W-, & Y-Frame Push-in Terminal Kit (3 Wires) Push-in Terminal Kit (6 Wires) Ring Tongue Kit 1a Ring Tongue Kit 1b Ring Tongue Kit 1a & 1b Trip Unit 12-Pin Connectors External Voltage Sensing Wiring Kit Table 63: S47074 S47075 Finger Cluster (Each) Cluster Grease (12 oz. Tube) Cluster Positioning Tool Cluster Reset Tool Cluster Service Kit T-Frame 80.00 240.00 S33101 S47506 228.00 266.00 164.00 132.00 1504.00 250.00 1886.00 S33101 S47507 $ Price S47849 S47850 S48912 S48913 S48914 S33101 S48533 228.00 266.00 120.00 240.00 64.00 64.00 126.00 228.00 266.00 Certified Test Reports Catalog Number Test Report $ Price S33166 S48899 S47542 CLUSRETOOL CLUSTOOLSK W- & Y-Frame 120.00 240.00 N/A Table 68: Catalog Number $ Price S33098 S33099 N/A Finger Cluster and Cluster Tools Description Drawout $ Price Circuit Breaker Cradle $ Price 4804930501B 4804930501C 252.00 132.00 Circuit breaker/cradle serial number also required if report is ordered after circuit breaker/cradle is shipped. Certified test reports are standard for ANSI circuit breakers and cradles. Order certified test reports for UL and IEC products as desired. Includes positioning tool, reset tool and a grease tube. Table 64: Table 69: Test Kit and External Power Supply Module Description Hand-Held Test Kit Full-Function Test Kit FFTK Report Generator Software Seven-Pin Test Cable (for connection between test kit and trip unit) Two-Pin Test Cable (for connection between test kit and trip unit) 230 Vac Filtered Power Cord 120 Vac Filtered Power Cord Primary Injection Test Adapter NW Phenix Primary Injection Kit NW Multi Amp Primary Injection Kit NT Primary Injection Kit Trip Unit Seal (6 pieces) Catalog Number S33594 S33595 FFTKRPTV10 5386.00 33792.00 800.00 S48907 1488.00 S48908 784.00 S48856 S48855 S33937 166.00 60.00 252.00 ULW10025 ULW10026 ULW10027 MICROTUSEAL 4000.00 4000.00 4000.00 60.00 Description Power Supply with 24-30 Vdc Input Power Supply with 48/60 Vdc Input Power Supply with 125 Vdc Input Power Supply with 110-130 Vac Input Power Supply with 200-240 Vac Input Power Supply with 380-415 Vac Input Battery Backup (12 Hours) Trip Unit Battery for Trip Indicator Lights Table 66: Crossbar for W-Frame Circuit Breaker or Cradle Crossbar for Y-Frame Circuit Breaker or Cradle Set of Two Lifting Hooks Catalog Number S48900 S48901 S48906 Catalog Number Mounting Brackets for horizontal mount Mounting Brackets for vertical mount S47828 S47829 2304.00 S48612 2304.00 Cable Interlock S33209 248.00 S33209 Cable Mounting Plate S33200 1234.00 S33201 Cable Interlock Kit for three circuit breakers Three main circuit breakers Two main circuit breakers and one tie circuit breaker Two main circuit breakers and one generator circuit breaker 248.00 S33209 1234.00 S47926 248.00 1234.00 S48610 S48609 S48608 3686.00 3686.00 3686.00 3260.00 438.00 $ Price 7738.00 8912.00 3722.00 $ Price Table 70: S47936 S47939 S47939U S47939L S47940 S47944 S47092 64274 S47034 S47035 S47036 S47037 S47038 S47039 S47040 S47041 S48857 W- & YFrame $ Price Miscellaneous Spare Parts for Masterpact™ NW Circuit Breakers Description Type S Arc Chute (each) for: UL: NW08—NW30 N/H/HF ANSI: NW08—NW32 N1/H1/H2/H3/HA IEC: NW08—NW40 N1/H1/H2/NA/HA/HF Type G Arc Chute (each) for: UL: NW40—NW60 H/HF, NW20—NW60 L ANSI: NW40—NW50 H2/H3/HA, NW32—NW50 L1 IEC: NW50—NW63 H1/H2/HA, NW20—NW40 H3 Type B Arc Chute (each) for: UL: NW08—NW16 L ANSI: NW08—NW20 L1 IEC: NW08—NW20 L1 Faceplate cover IEC fixed & drawout, UL/ANSI fixed UL/ANSI drawout non limiter UL/ANSI drawout limiter (L/L1 AIR) Spring charging handle Masterpact NW racking handle Masterpact NT racking Handle Cradle interlock defeat tool UL/ANSI 3 cluster support UL/ANSI 2 cluster support UL/ANSI 4 cluster support limiter UL/ANSI 6 cluster support limiter UL/ANSI 6 cluster support UL/ANSI 4 cluster support UL/ANSI 10 cluster support UL/ANSI 10 cluster support limiter Cluster support mounting tool $ Price 412.00 588.00 412.00 430.00 172.00 344.00 344.00 60.00 214.00 3200.00 Required for mounting cluster support on standard Masterpact NW drawout circuit breaker. Tool is not required for ArcBlok™ circuit breakers. W- and Y-Frame Only 22 $ Price Complete kit. Complete kit requires: (2) S47926 + (1) S33209 or (2) S33200 + (1) S33209 or (2) S33201 + (1) S33209. S47937 Fixed Circuit Breaker Mounting Brackets (Set of 2) Description S33913 $ Price 1130.00 T-Frame Fixed Rod Interlock Kit for S33912 2304.00 two circuit breakers Cable Interlock Kit for two circuit breakersl S47935 Lifting Device Kits Description Table 67: 685823 685824 685825 685826 685827 685829 685831 S33593 $ Price Catalog Number 24 Vdc Power Supply and Battery Backup Modules (Not UL Listed) Catalog Number T-Frame Drawout Type of Interlock Kit $ Price Used for testing Micrologic trip units. Included in the price of the hand-held / full-function test kits. Kit for replacement only. Used for testing STR trip units. Included in the price of the hand-held / full-function test kits. Kit for replacement only. Included in the price of the full-function test kit. Kit for replacement only. Included in the price of the hand-held test kit. Kit for replacement only. For compliance with NEC 240.6(c). Table 65: Source Changeover Interlocks 458.00 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Accessories Masterpact MP/MC Retrofit Kits These bus adapter kits will allow direct mechanical replacement of the old Masterpact MP/MC (UL/ANSI) with the Masterpact NW circuit breaker. Order the corresponding Masterpact NW circuit breaker without connectors and the retrofit kit for a complete replacement. Some electrical accessories characteristics and wiring connections may not be identical between Masterpact MP/MC and Masterpact NW. Evaluation with regards to products compatibility must be completed before commissioning the replacement circuit breaker. Kit is shown as a set of 3 (3-pole) or 4 (4-pole) for Top and Bottom connection. Masterpact MP: UL 489 circuit breaker Masterpact MC: UL1066 (ANSI C37) circuit breaker Table 71: Retrofit Kits Old Circuit Breaker Being Replaced New Circuit Breaker Without Connectors Retrofit Kit 3-Pole Top Retrofit Kit 3-Pole Bottom $ Price Retrofit Kit 4-Pole Top $ Price $ Price Retrofit Kit 4-Pole Bottom $ Price Masterpact MP/MC UL/ANSI Drawout Circuit Breakers MP/MC 08-16 Vertical NW08-16 S64120T 3758.00 S64120B 3758.00 S64131T 5138.00 S64131B 5138.00 MP/MC 08-16 Horizontal NW08-16 S64121 3946.00 S64122 3946.00 S64132 5394.00 S64133 5394.00 MP/MC 20 Vertical NW20 S64123 3946.00 S64124 3946.00 S64134 5394.00 S64135 5394.00 MP 25-30 Vertical NW25-30 S64125 7374.00 S64125 7374.00 S64136 10536.00 S64137 10536.00 MC 32 Vertical NW32 S64126 9002.00 S64126 9002.00 N/A MP/MC 40 Vertical NW40 S64127 11710.00 S64128 11710.00 S64138 15464.00 S64139 15464.00 15464.00 S64170 15464.00 MP/MC 50 Vertical NW50 S64129 11710.00 S64169 11710.00 S64140 MP 63 Vertical NW60 S64130 22338.00 S64130 22338.00 N/A N/A N/A N/A N/A N/A N/A Masterpact MP UL Fixed Circuit Breakers MP 08-16 Vertical NW08-16 S64141 3946.00 S64142 3946.00 S64153 5394.00 S64154 5394.00 MP 08-16 Horizontal NW08-16 S64143 3946.00 S64144 3946.00 S64155 5394.00 S64156 5394.00 MP 20 Vertical NW20 S64145 3946.00 S64146 3946.00 S64157 5394.00 S64158 5394.00 NW25-30 S64147 7374.00 S64148 7374.00 S64159 10536.00 S64160 10536.00 MP 40 Vertical NW40 S64149 11710.00 S64150 11710.00 N/A N/A N/A N/A MP 50 Vertical NW50 S64151 11710.00 S64152 11710.00 N/A N/A N/A N/A MP 25-30 Vertical Masterpact M Retrofit Kits These bus adapter kits will allow direct mechanical replacement of the old Masterpact M (IEC) with the Masterpact NW circuit breaker. Order the corresponding Masterpact NW circuit breaker without connectors and the retrofit kit for a complete replacement. Some electrical accessories characteristics and wiring connections may not be identical between Masterpact M and Masterpact NW. Evaluation with regards to products compatibility must be completed before commissioning the replacement circuit breaker. Kit is shown as a set of 3 (3-pole) or 4 (4-pole) for Top and Bottom connection. Masterpact M: IEC 60947-2 circuit breaker Table 72: Retrofit Kits Old Circuit Breaker Being Replaced New Circuit Breaker Without Connectors Retrofit Kit 3-Pole Top $ Price Retrofit Kit 3-Pole Bottom $ Price Retrofit Kit 4-Pole Top $ Price Retrofit Kit 4-Pole Bottom $ Price Masterpact M IEC Drawout Circuit Breakers M 08-12 N1/NI Vertical NW08-12 S48966 3912.00 S48966 3912.00 S48966Q 5214.00 S48966Q 5214.00 M 08-12 N1/NI Horizontal NW08-12 S48951 3912.00 S48964 3912.00 S48951Q 5214.00 S48964Q 5214.00 M 08-12 H1/H2/HI/HF Vertical NW08-12 S48969 3912.00 S48969 3912.00 S48969Q 5214.00 S48969Q 5214.00 M 08-12 H1/H2/HI/HF Horizontal NW08-12 S48954 3912.00 S48965 3912.00 S48954Q 5214.00 S48965Q 5214.00 5214.00 M 16 N1/H1/H2/NI/HI/HF Vertical NW16 S48969 3912.00 S48969 3912.00 S48969Q 5214.00 S48969Q M 16 N1/H1/H2/NI/HI/HF Horizontal NW16 S48954 3912.00 S48965 3912.00 S48954Q 5214.00 S48965Q 5214.00 M 20-25 N1/H1/H2/NI/HI/HF Vertical NW20-25 S48970 6012.00 S48970 6012.00 S48970Q 7314.00 S48970Q 7314.00 M 20-25 N1/H1/H2/NI/HI/HF Horizontal NW20-25 S48957 6012.00 S48958 6012.00 S48957Q 7314.00 S48958Q 7314.00 M 32 H1/H2/HI/HF Vertical NW32 S48974 7062.00 S48974 7062.00 S48978Q 8364.00 S48978Q 8364.00 M 32 H1/H2/HI/HF for neutral left NW32 S48973 7062.00 S48973 7062.00 S48976Q 8364.00 S48977Q 8364.00 M 32 H1/H2/HI/HF for neutral right NW32 S48973 7062.00 S48973 7062.00 S48977Q 8364.00 S48976Q 8364.00 Masterpact M IEC Fixed Circuit Breakers M 08-12 N1/NI Horizontal NW08-12 S48951 3912.00 S48964 3912.00 S48951Q 5214.00 S48964Q 5214.00 M 08-12 H1/H2/HI/HF Horizontal NW08-12 S48954 3912.00 S48965 3912.00 S48954Q 5214.00 S48965Q 5214.00 5214.00 M 16 N1/H1/H2/NI/HI/HF Horizontal M 20-25 N1/H1/H2/NI/HI/HF Horizontal M 32 H1/H2/HI/HF Horizontal © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 NW16 S48954 3912.00 S48965 3912.00 S48954Q 5214.00 S48965Q NW20-25 S48957 6012.00 S48958 6012.00 S48957Q 7314.00 S48958Q 7314.00 NW32 S48962 7062.00 S48961 7062.00 S48960Q 8364.00 S48960Q 8364.00 DE2F Discount Schedule 23 Pricing Guide Masterpact™ NT/NW Universal Power Circuit Breakers Accessories Masterpact MP/MC/M Neutral CT Retrofit Kits If required, select the appropriate neutral CT based on the sensor plug ampere rating, Type (UL/ANSI or IEC) and frame rating of the Masterpact NW circuit breaker Examples: For UL Masterpact NW 4000 A Frame (NW 40) with 3000 A Sensor plug, select NCT catalog no. S64164 For IEC Masterpact NW 4000 A Frame (NW 40) with 3000 A Sensor plug, select NCT catalog no. S64163 Kit includes the Masterpact NW neutral sensor with special bus connection that provides exact touch point to the existing bus of the Masterpact MP/MC/M neutral sensor being replaced. Table 73: Neutral CT Retrofit Kits Sensor Plug Rating (A) 24 UL/ANSI Circuit Breaker Frame IEC Circuit Breaker Frame NCT Catalog No. $ Price 100–250 NW 08 NW 08 S64161 2428.00 400–2000 NW 08-20 NW 08-20 S64162 2428.00 2500–4000 NW 25-32 NW 25-40 S64163 2428.00 2000–6300 NW 40-60 NW 50-63 S64164 4870.00 DE2F Discount Schedule © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Appendix A—Selection Page 1 of 2 Request for Quotation Form For faster quote processing, please use the following request for quotation form. For each section, check the applicable box or enter value corresponding to your choice. Note: this request for quotation form does not take into account incompatibilities. Orders to be placed on CSSS. Square D: Date Customer Name: From Location Account No. Q2C No. Phone No. Fax No. Contact Name Phone No. Location Fax No. Messages Circuit Breakers or Switches Brand: Quantity: ______ Schneider Electric Standard ANSI Type Square D UL IEC NT Number of Poles RFQ No. NW 3 4 Cradle Secondary Disconnects Choose one: Push-in terminal (standard) Ring terminal Frame rating Amperes: ______ Accessories for Remote Operation Sensor plug rating Amperes: ______ Spring-charging motor (MCH) Interrupting/ Withstand rating N, N1, NA, L, LF, L1, L1F, H, H1 H2, H3, H10, HA, HA10, HF, HB, HC Cradle options: _____ Circuit breaker with cradle Circuit breaker without cradle Cradle only Fixed circuit breaker ArcBlok™ circuit breaker with cradle without cradle ArcBlok cradle only Shunt close (XF): Standard or Communication ______ Vac ______ Vdc Shunt trip (MX1): Standard or Communication ______ Vac ______ Vdc Additional shunt trip (MX2) OR Micrologic Trip Units Dummy Trip Unit (for switch only) 2.0 3.0 5.0 Trip Unit with Ammeter Basic protection 2.0A Selective protection Selective protection + equip. ground fault 3.0A 5.0A 6.0A Trip Unit with Power Metering Selective protection Selective protection + equip. ground fault 5.0P 6.0P Trip Unit with Harmonic Metering Selective protection Selective protection + equip. ground fault 5.0H 6.0H Rating plug type (A=UL/ANSI; R=IEC) (for non-standard, see page 17) Choose one: ______ Vac ______ Vdc Fixed–time delayed ______ Vac ______ Vdc Adjustable–time delayed ______ Vac ______ Vdc Electrical closing push button Remote reset after fault trip (RES) (incompatible with SDE2) (BPFE) 110–130 Vac 200–240 Vac Wiring for Cradle Circuit breaker communication module (BCM) wiring Wiring for zone-selective interlocking (ZSI), modified differential ground fault (MDGF), neutral current transformer (CT) and 24 V power supply Wiring for programmable contact modules (M2C and M6C) Wiring for additional overcurrent trip switch (SDE2) or electrical reset (RES) Wiring for undervoltage trip (MN) or additional shunt trip (MX2) Wiring for shunt trip (MX), shunt close (XF) and spring-charging motor (MCH) Wiring for four additional form C auxiliary switches (push-in terminals) or 2a+2b auxiliary switches (ring terminals) (OF) Wiring for eight additional form C auxiliary switches (push-in terminals) (OF) Manufacturing Numbers Provided with Quotation Micrologic™ Trip Unit Accessories (M2C) (M6C) (BCM) MODBUS® circuit breaker com. module MODBUS cradle com. module (CCM) Restraint interface module (RIM) External power supply (24 Vdc) input voltage____ Number of power supplies/circuit breaker: 1 or 2 Battery backup quantity: 1 or 2 External voltage sensing Automatic reset (RAR) © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Instantaneous Wiring for ready-to-close contact (PF) ______ External neutral sensor (CT) Mod. differential ground-fault (MDGF) Source ground return (SGR) Choose one: Programmable contact module Programmable contact module ______ Vac ______Vdc Undervoltage trip (MN)—choose one Optional characterization for CTs Basic Trip Unit Basic protection Selective protection ______ Vac ______ Vdc Circuit Breaker: Cradle: See Delivery Schedule on the next page Not available on Masterpact NT (T-frame circuit breaker) Complete only if ordering cradle without circuit breaker. ArcBlok circuit breakers and cradles are available for ANSI and UL489 3-pole circuit breakers and cradles only. ArcBlok devices are not available for interrupting / withstand ratings of L, LF, L1, L1F, HF or HB. 25 Appendix A—Selection Page 2 of 2 Request for Quotation Form Cradle Connections Front-connected Auxiliary, Alarm and Cradle Position Switches Auxiliary switch (OF) choose one: Push-in type terminal or 4a/4b form C (std.) 4a/4b low level NT 8a/8b form C 12a/12b form C Overcurrent trip switches Standard (1a/1b form C) 800–3200 A Ring terminal 2a + 2b 4a + 4b Ready-to-close switch (PF) (FCF) (FCT) 4000 A Front-connected flat 4000–5000 A Front-connected “T” (FCT) (FCF) Rear-connected (SDE1) standard Additional overcurrent trip switches (choose one) (1a/1b form C) (incompatible with RES) (1a/1b form C) (incompatible with RES) Front-connected flat Front-connected “T” (SDE2) (low-level SDE2) Std low level Push-in type cradle position switches (1a/1b form C) Qty 800–3200 A Rear-connected “T” vertical Rear-connected “T” horizontal (RCTV) (RCTH) 2000 A L1/L 3200 A (ANSI) Rear-connected offset vertical Rear-connected offset vertical (RCOV) (RCOV) 4000-6300 A Rear connected “T” vertical Rear-connected “T” horizontal (RCTV) (RCTH) Cradle Interlocking and Accessories Connected position (max. qty.: 3 NW/3 NT) (CE) ______ Door interlock(VPEL) Test position (max. qty.: 3 NW/1 NT) (CT) ______ Disconnected position (max. qty.: 3 NW/2 NT) (CD) ______ Racking interlock between racking crank and Off position —std. on UL/ANSI (IBPO) Low-level cradle position switch Racking interlock (VPOC) Choose one: Qty Connected/Closed switch (max. qty.: 8) (EF) ______ Connected/Closed switch (max. qty.: 8) (low-level EF) ______ Ring terminal type cradle position switches (1a or 1b contact) qty/type _________ Test position (max. 1a or 1b) qty/type _________ Disconnected position (max. 3a or 3b) qty/type _________ Cradle Brkr Padlockable push button cover Ronis Profalux Not available on Masterpact NT (T-frame circuit breaker) Not available on IEC circuit breaker Not available on IEC Masterpact NT. Standard with IEC offer. Manufacturing Number Provided with Quotation Circuit Breaker: Cradle: standard Auxiliary terminal shield Lock cradle in all positions—std. on UL/ANSI Miscellaneous Accessories Mechanical operation counter Shutter (Required option for IEC NW circuit breakers Shutter with padlock provision and position indicator Padlock provision only One key lock (select manufacturer below) Two key locks keyed alike (select manufacturer below) Two key locks keyed differently (select manufacturer below) Key lock manufacturer: Kirk Schneider Electric Cradle rejection kit Metering CT (optional for UL/ANSI only) Connected position (max. 3a or 3b) Locking and Interlocking Automatic spring discharge (DAE)—std. on UL/ANSI Transparent cover (drawout circuit breaker only) Lifting device for T-frame, W-frame, or Y-frame circuit breaker lifting hooks (set of 2) lifting bar (short) lifting bar (long) Masterpact NW/NT remote racking device Test Equipment Castell Hand-held test kit Full-function test kit Test report for circuit breaker, standard for ANSI, check for UL, IEC Test report for cradle, standard on ANSI, check for UL, IEC List Price $ $ Delivery (from receipt of order) Total $ Delivery Schedule Circuit breaker and cradle to be shipped together Cradle to be shipped prior to circuit breaker Schneider Electric Conditions of Sale Apply 26 © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Appendix B—DC Circuit Breakers Selection Page 1 of 2 REQUEST FOR QUOTATION FORM For faster quote processing, please use the following request for quotation form. For each section, check the applicable box or enter values corresponding to your choice. Note: this request for quotation form does not take into account incompatibilities. Order to be placed on CSSS. Date Customer Name: RFQ No.: From Location Account No.: Q2C No.: Phone No. Fax No. Contact Name: Phone No.: Location: Fax No.: Messages UL Listed Circuit Breaker Qty Cradle Secondary Disconnects NW08 Masterpact Type Choose One: NW12 Push-in terminal (standard) NW16 Ring terminal (UL option only) NW20 NW25 Accessories for Remote Operation NW30 Spring-charging Motor (MCH) NW40 Circuit Breaker Type N and H are available Shunt close (XF) 1250 to 2500 A Type of Sensor 2500 to 5400 A Shunt Trip (MX1) 5000 to 11000 A Load Connection Type of Equipment Type of Connection Version C Version C1 V ac V dc ________ V ac ________ V dc ________ V ac ________ V dc Additional shunt trip (MX2) ________ V ac Fixed OR ________ V dc Drawout chassis Undervoltage Trip (MN) Vertical Top Bottom Horizontal Top Bottom IEC Rated Circuit Breaker or Switch Disconnector –choose one Instantaneous Fixed-time delay Qty NW10 Masterpact Type ________ ________ Adjustable-time delay NW20 NW40 ________ V ac ________ V dc ________ V ac ________ V dc ________ V ac ________ V dc Circuit Breaker Type N, H Electrical closing push button (BPFE) Switch-disconnector Type HA Remote reset after fault trip (RES) 100–130 Vac 1250 to 2500 A (incompatible with SDE2) 200–240 Vac Type of Sensor 2500 to 5400 A Wiring for Cradle (Complete only if ordering cradel without circuit breaker) Load Connection C, D, E Wiring for additional overcurrent trip switch (SED2) or electrical reset (RES) Fixed Wiring for undervoltage trip (MN) or additional shunt trip (MX2) 5000 to 11000 A Type of Equipment Type of Connection Drawout Vertical Top Bottom (Wiring for shunt trip (MX), shunt close (XF) and spring-charging motor (MCH) Horizontal Top Bottom Wiring for ready-to-close contact (PF) Wiring for four additional Form C auxiliary switches (push-in terminals) or 2a+2b auxiliary switches (ring terminals (OF) Wiring for eight additional form C auxiliary switches (Push-in Terminals) (OF) Manufacturing Numbers Provided with Quotation Circuit Breaker: ___________________________________________ Cradle: __________________________________________________ © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 27 Appendix B—DC Circuit Breaker Selection Page 2 of 2 REQUEST FOR QUOTATION FORM Cradle Interlocking and Accessories Door Interlock Auxiliary, Alarm and Cradle Position Switches Racking interlock between racking crank and Off position Auxiliary Switch (OF) Choose one: Push-in type terminal std on UL, check for IEC or Ring terminal 4a/4b form C (std.) 2a + 2b 8a/8b form C 4a + 4b Racking interlock (VPOC) Automatic spring discharge (DAE) 12A/12B form C standard Auxiliary terminal shield Overcurrent trip switches Standard (1a/1b form C) Miscellaneous Accessories (SDE1) standard Mechanical operation counter Additional overcurrent trip switches (choose one) Shutter (1a/1b form c) (incompatible with RES) (SDE2) (1a/1b form c) (incompatible with RES) (low level (SDE2) Ready-to-close switch (PF) std on UL, check for IEC Cradle rejection kit Std Shutter with padlock provision and position indicator Locking and Interlocking low-level Push-in type cradle position switches (1a/1b form C) Connected position (max. qty: 3) qty ______ Test position (max. qty: 3) qty ______ Disconnected position (max. qty: 3) qty ______ Padlock provision only Brkr. (Select manufacturer below) Two key locks keyed alike (Select manufacturer below) Qty. Connected/Closed switch (max. qty: 8) (EF) ______ Connected/Closed switch (max. qty: 8) (low-level EF) _____ Two key locks keyed differently (Select manufacturer below) Key lock manufacturer Ring terminal type cradle position switches (1a or 1b contact) Connected position (max. 3a or 3b) qty ______ Test position (max. 1a or 1b) qty ______ Disconnected position (max. 3a or 3b) qty ______ Std One key lock Low-level cradle position switch Choose one: Cradle Padlockable push button cover Kirk Ronis Schneider Electric Profalux Castell Test report for circuit breaker Test report for cradle Manufacturing Number (provided with quotation) List Price Circuit Breaker: $ Cradle: $ Delivery (from receipt of order) Total $ Delivery Schedule Circuit Breaker and cradle to be shipped together Cradle to be shipped prior to circuit breaker Schneider Electric Conditions of Sale Apply 28 © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 Appendix C—Keylock Selection Kirk® or Schneider Electric™ Keylock Order Information Form Use: To supply order information when the Kirk key or Schneider Electric lock for the part numbers listed below are ordered Q2C # : Job Name : Date Completed : Line Items(s) : Completed By : From (Location) : Purchase Order # ________________________________________ Circuit Breaker Catalog # :__________________________________ Choose one: Qty Keylock Schneider Used On Electric Drawing Kirk Single Lock (Part No. 35635) — Kirk Single Lock F 1/2 E (Part No. 35635) — CK Circuit Breakers Only Kirk Single Lock (Horizontal Mount) SK41683-1 48186-220-50 PowerPact M-, P-, and R-Frame Circuit Breakers Only Kirk Single Lock (Vertical Mount) KLF030010 48185-267-01 PowerPact M- and P-Frame Circuit Breakers Only Kirk Double Lock (Vertical Mount) KFL003720 48185-266-01 PowerPact M-,and P-Frame Circuit Breakers Only Kirk Double Lock (Horizontal Mount) SK41686-1 48186-224-50 PowerPact R-Frame Circuit Breakers Only Masterpact NT/NW and PowerPact P Cradle Only Schneider Electric Single Lock 12A-1MG — Masterpact NT/NW and PowerPact P Cradle Only Schneider Electric Single Lock (Horizontal Mount) VFR-3/8-E 48186-221-50 PowerPact M-, P-, and R-Frame Circuit Breakers Only Schneider Electric Single Lock (Vertical Mount) VF-3/8-E 48185-267-01 PowerPact M- and P-Frame Circuit Breakers Only Schneider Electric Double Lock (Vertical Mount) VM2F-3/8-EE 48185-266-01 PowerPact M- and P-Frame Circuit Breakers Only Schneider Electric Double Lock (Horizontal Mount) VM2FR-3/8-EE 48186-224-50 PowerPact R-Frame Circuit Breakers Only Please note: Since these are registered keys, the following information is REQUIRED before the order can be processed. Ultimate User’s Name and Address Ultimate User’s Name and Address Contact Person and Phone Number Keyed Alike Keyed Differe t Qty. Catalog No. Qty. Catalog No. Qty. Catalog No. Qty. Catalog No. Sets Keyed Alike Keyed Like Existing Lock Qty. Key / Lock No. Catalog No. Submit to: Customer Service © 2000-2013 Schneider Electric All Rights Reserved Prices subject to change without notice. 07/2013 At Location: Cedar Rapids Plant FAX: 319-369-6448 29 Schneider Electric USA, Inc. 1415 S. Roselle Road Palatine, IL 60067 USA 1-888-778-2733 www.schneider-electric.us © 2000-2013 Schneider Electric All Rights Reserved Square D™, Schneider Electric™, and Masterpact™ are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are the property of their respective owners. 0613PL0001 R07/13 Replaces 0613PL0001 R10/12 07/2013
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : mcr126 Create Date : 1990:05:17 09:10:16Z Modify Date : 2013:08:28 09:06:57-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : FrameMaker 10.0.2 Metadata Date : 2013:08:28 09:06:57-05:00 Format : application/pdf Title : 0613PL0001R0713.fm Creator : mcr126 Producer : Acrobat Distiller 10.1.7 (Windows) Document ID : uuid:1e4bdf06-a1f6-4410-b365-18077ce2c411 Instance ID : uuid:2a52504a-552d-4b22-8ae8-2bde8afab815 Page Mode : UseOutlines Page Count : 30EXIF Metadata provided by EXIF.tools