Product Detail Manual
2014-09-05
: Pdf 104333-Attachment 104333-Attachment 686334 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 121
Download | |
Open PDF In Browser | View PDF |
Amperage Chart & Electric Heat Products Limited Warranty 2 K.W B.T.U.H. Rating 00.5 01.0 02.0 03.0 04.0 05.0 06.0 07.0 08.0 09.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 21.0 22.0 23.0 24.0 25.0 26.0 27.0 28.0 29.0 30.0 31.0 32.0 33.0 34.0 35.0 36.0 37.0 38.0 39.0 40.0 41.0 42.0 43.0 44.0 45.0 46.0 47.0 48.0 49.0 50.0 51.0 52.0 53.0 54.0 55.0 56.0 57.0 58.0 59.0 60.0 1,706 3,413 6,826 10,239 13,652 17,065 20,478 23,891 27,304 30,717 34,130 37,543 40,956 44,369 47,782 51,195 54,608 58,021 61,434 64,847 68,260 71,673 75,086 78,499 81,912 85,325 88,738 92,151 95,564 98,977 102,390 105,803 109,216 112,629 116,042 119,455 122,868 126,281 129,694 133,107 136,520 139,933 143,346 146,759 150,172 153,585 156,998 160,411 163,824 167,237 170,650 174,063 177,476 180,889 184,302 187,715 191,128 194,541 197,954 201,367 204,780 208 Volt AMP Rating 1 PH 2.4 4.8 9.6 14.4 19.2 24.0 28.8 33.6 38.5 42.8 48.1 52.9 57.7 62.5 67.3 72.1 76.9 81.7 86.5 91.3 96.1 100.0 105.8 110.6 115.4 120.2 125.0 129.8 134.6 139.4 144.2 149.0 153.8 158.6 163.4 168.2 173.0 177.8 182.6 187.4 192.2 197.0 201.8 206.6 211.4 216.2 221.0 225.8 230.6 235.4 240.2 245.0 249.8 254.6 259.4 264.2 269.0 273.8 278.6 283.4 288.2 3 PH 1.4 2.8 5.5 8.3 11.1 13.8 16.6 19.4 22.2 24.9 27.4 30.5 33.2 36.0 38.8 41.5 44.3 47.1 49.8 52.6 55.1 58.2 60.9 63.7 66.5 69.2 72.0 74.8 77.2 80.3 83.1 85.9 88.7 91.5 94.3 97.1 99.9 102.7 105.5 108.3 111.1 113.9 116.7 119.5 122.3 125.1 127.9 130.7 133.5 136.3 139.1 141.9 144.7 147.5 150.3 153.1 155.9 158.7 161.5 164.3 167.1 220 Volt AMP Rating 1 PH 2.3 4.5 9.1 13.6 18.2 22.7 27.3 31.8 36.4 40.9 45.4 50.0 54.5 59.1 63.6 68.2 72.7 77.3 81.8 86.4 90.9 95.6 100.0 14.5 109.1 113.6 118.2 122.7 128.2 131.8 136.4 140.9 145.4 149.9 154.4 158.9 163.4 167.9 172.4 176.9 181.4 185.9 190.4 194.9 199.4 203.9 208.4 212.9 217.4 221.9 226.4 230.9 235.4 239.9 244.4 248.9 253.4 257.9 262.4 266.9 271.4 3 PH 1.3 2.6 5.2 7.9 10.4 13.1 15.7 18.4 20.9 23.3 26.2 28.6 31.5 34.1 36.7 39.1 41.9 44.3 47.2 49.6 52.5 55.1 57.7 60.4 62.9 65.3 68.3 70.9 73.5 76.0 78.7 81.3 83.9 86.5 89.1 91.7 94.3 96.9 99.5 102.1 104.7 107.3 109.9 112.5 115.1 117.7 120.3 122.9 125.5 128.1 130.7 133.3 135.9 138.5 141.1 143.7 146.3 148.9 151.5 154.1 156.7 230 Volt AMP Rating 1 PH 2.2 4.3 8.7 13.0 17.5 21.7 26.1 30.4 34.9 39.1 43.5 47.8 52.1 56.9 60.9 65.2 69.6 73.9 78.3 82.6 86.9 91.3 95.7 100.0 104.3 108.6 113.0 117.4 121.7 126.0 130.4 134.7 139.0 143.3 147.6 151.9 156.2 160.5 164.8 169.1 173.4 177.7 182.0 186.3 190.6 194.9 199.2 203.5 207.8 212.1 216.4 220.7 225.0 229.3 233.6 237.9 242.2 246.5 250.8 255.1 259.4 3 PH 1.3 2.5 5.0 7.5 10.1 12.6 15.1 17.6 20.1 22.6 25.1 27.6 30.2 32.7 35.2 37.7 40.2 42.7 45.2 47.7 50.3 52.9 55.3 57.9 60.3 62.8 65.3 67.8 70.3 72.9 75.4 77.9 80.4 82.9 85.4 87.9 90.4 92.9 95.4 97.9 100.4 102.9 105.4 107.9 110.4 112.9 115.4 117.9 120.4 122.9 125.4 127.9 130.4 132.9 135.4 137.9 140.4 142.9 145.4 147.9 150.4 Note: All custom built products are subject to 100% cancellation/ restock charges. Heat Products 198 Series Elements 1 Year Elements in Baseboard 10 Years All Other Heating Products 1 Year Thermostats & Controls 2 Years 240 Volt AMP Rating 1 PH 2.1 4.2 8.3 12.5 16.6 20.8 25.0 29.1 33.3 37.7 41.7 45.8 50.0 54.2 58.3 62.5 66.7 70.8 75.0 79.2 83.3 87.5 91.7 95.8 100.0 104.1 108.3 112.5 116.6 120.8 125.0 129.2 133.4 137.6 141.8 146.0 150.2 154.4 158.6 162.8 167.0 171.2 175.4 179.6 183.8 188.0 192.2 196.4 200.6 204.8 209.0 213.2 217.4 221.6 225.8 230.0 234.2 238.4 242.6 246.8 251.0 3 PH 1.2 2.4 4.8 7.2 9.6 12.0 14.4 16.8 19.2 21.4 24.0 26.4 28.6 31.3 33.7 35.1 38.5 40.9 43.3 45.7 48.1 50.5 52.9 55.3 57.7 60.1 62.5 64.7 67.3 69.7 72.1 74.5 76.9 79.3 81.7 84.1 86.5 88.9 91.3 93.7 96.1 98.5 100.9 103.3 105.7 108.1 110.5 112.9 115.3 117.7 120.1 122.5 124.9 127.3 129.7 132.1 134.5 136.9 139.3 141.7 144.1 277 440 480 550 Volt Volt Volt Volt AMP AMP AMP AMP Rating Rating Rating Rating 1 PH 1.8 3.6 7.2 10.8 14.4 18.1 21.7 25.3 28.9 32.5 36.1 39.7 43.3 46.9 50.5 54.2 57.8 61.4 65.0 68.6 72.2 75.8 79.4 83.0 86.6 90.3 93.9 97.5 101.1 104.7 108.3 111.9 115.5 119.1 112.7 126.4 130.0 133.6 137.2 140.7 144.4 148.0 151.6 155.2 158.8 162.5 166.1 169.7 173.3 176.9 180.5 184.1 187.7 191.3 194.9 198.6 202.2 205.8 209.4 213.0 216.6 3 PH 0.6 1.3 2.6 3.9 5.2 6.6 7.9 9.2 10.5 11.8 13.2 14.5 15.8 17.1 18.4 19.8 21.1 22.4 23.7 25.1 26.4 27.7 29.0 30.3 31.7 33.0 34.3 35.6 36.9 38.3 39.6 40.9 42.2 43.5 44.8 46.1 47.4 48.7 50.0 51.3 52.6 53.9 55.2 56.5 57.8 59.1 60.4 61.7 63.0 64.3 65.6 66.9 68.2 69.5 70.8 72.2 73.5 74.9 76.2 77.5 78.8 3 PH 0.6 1.2 2.4 3.6 4.8 6.0 7.2 8.4 9.6 10.8 12.0 13.2 14.4 15.6 16.8 18.0 19.2 20.4 21.6 22.8 24.0 25.2 26.4 27.6 28.8 30.1 31.3 32.5 33.7 34.9 36.1 37.3 38.5 39.7 40.9 42.1 43.3 44.5 45.7 46.9 48.1 49.3 50.6 51.8 53.0 54.2 55.4 56.6 57.8 59.0 60.2 61.4 62.6 63.8 65.0 66.2 67.4 68.6 69.8 71.0 72.2 3 PH 0.5 1.0 2.1 3.1 4.2 5.2 6.3 7.3 8.4 9.5 10.5 11.6 12.6 13.7 14.7 15.8 16.9 17.9 19.0 20.0 21.1 22.1 23.1 24.3 25.3 26.4 27.4 28.5 29.5 30.6 31.7 32.7 33.8 34.8 35.9 36.9 38.0 39.0 40.1 41.1 42.2 43.2 44.3 45.3 46.4 47.4 48.5 49.5 50.6 51.6 52.7 53.7 54.8 55.8 56.9 57.9 58.8 59.9 60.9 62.3 63.0 Products manufactured by TPI Corporation are warranted to the original consumer to be free from defects in material and workmanship for twelve (12) months from the original date of purchase. The TPI warranty does not cover products modified outside our factory, damage or failure caused by acts of God, abuse, misuse, connected to or placed on other than rated voltage, abnormal usage, faulty installation, failure to follow suggested maintenance procedures enclosed with the product, improper maintenance or any repairs other than those provided by an authorized TPI Corporation service center. There are no obligations or liabilities on the part of the corporation for consequential damages arising out of, or in connection with, the use or performance of the product, or other indirect damages with respect to loss of property, revenues, or profit, or costs of removal, installation or reinstallation. All implied warranties with respect to TPI products, including implied warranties for merchantability and implied warranties for fitness, are limited in duration to twelve (12) months from original date of purchase, except those products or parts of products which are warranted for longer periods. On such products or parts of products all implied warranties for merchantability and fitness are limited to the duration of the extended warranty period thereon. Some states do no allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts. The above exclusions or limitations may not apply to you. During the warranty period, TPI Corporation will, at its sole option, repair or replace any defective parts or products returned, freight prepaid, to the TPI Corporation factory or such other location as TPI Corporation may designate. Returned products must be packaged carefully and TPI Corporation shall not be responsible for damage in transit. When returning parts, the owner must provide the model number of the product and nature of difficulty being experienced. This warranty does not obligate TPI Corporation to bear the cost of labor in replacing any assembly, unit or component part thereof, nor does the company assume any liability for secondary charges, expenses for installing or removal, freight or damages. There will be charges rendered for product repairs made after out warranty period has expired. Proof of purchase, including date, must accompany request for in-warranty service. In any event, TPI Corporation’s maximum liability shall not in any case exceed the list price for the product claimed to be defective. This warranty gives to you specific legal rights and you may have other rights, which may vary, from state to state. For the name of you nearest authorized TPI Corporation service center, please write to TPI Corporation, P.O. Box 4973, Johnson City, Tennessee, 37602. In addition to the Limited Warranty stated above covering general products, TPI Corporation extends this warranty on the following listed products, which are warranted to the original consumer from the original date of purchase for the total time periods indicated herein to the left: Electric Heat Comfort Zones 3 INSULATION R-VALUE Recommended FHA Standard Minimum: Not Recommended Ceiling *R-24 *R-19 *R-11 Walls R-13 11 R-7 Floor R-24 11 ---- ZONE APPROXIMATE WATTAGE NEED PER SQUARE FOOT 1 8.6 10.0 14.6 2 7.7 9.0 13.1 3 7.1 8.2 12.0 4 6.4 7.4 10.8 5 6.0 7.0 10.2 *”R”values are industry standards for insulation effectiveness. Ask company representative for assistance if you do not know “R” for your present structure insulation. Baseboard or wall mount style? Recessed or surface type? It’s easy to select the heater that’s right for you. 1. Measure the size of the room(s) or area you intend to heat for square footage. You will need the length times the width to get this calculation. 2. Find your location on the map above. This determines your basic heating zone. 3. The chart shown below the map lists insulation values based on the effectiveness of the insulation presently in your home. Find your heating zone on the chart and the approximate wattage per square foot you will need. 4. Multiply the total number of square feet you intend to heat by the approximate wattage per square foot you just obtained. This will determine your total heating requirement in watts for the room. How Much Heat is Right For You? Figures are based on 15% total window and door openings in outside walls, and 3/4 total home air changes per hour. Typical frame-type construction with unheated basement or unventilated crawl space. If you do not have storm doors and windows, add 30% to the watts per square foot (multiply by 1.3). That’s all there is to it! Now choose the heater with a wattage equal to what you need. Your final selection will, of course, depend on available wall space, window placement, ect. Sample Calculation: Example = 10’ x 12’ room in Zone 3 with FHA standard insulation 1. Determine room square footage: 10’ x 12’ = 120 sq. ft. 2. Zone 3 with FHA standard insulation requires 8.2 watts per sq. ft. 3. Multiply square footage of room to be heated by the approximate wattage per square foot required. 120 sq. ft x 8.2 watts = 984 watts required. From this calculation it can be reasoned that a 1000 watt heater would be required. HLA Series Hazardous Location Fan Forced Unit Heater 4 FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR T-3B CLASS I, GROUP C & D, DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2. • Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain flammable gases, vapors, powdered metals or dust. • Permanently sealed, liquid to air, finned tube heat exchanger core. • Ethylene Glycol to water mixture used as a heat transfer fluid in the heater core, providing -45° C. (-49° F) freeze damage protection. • High-performance electric motor driven fan blows air across finned tubes to effect uniform heat transfer and area heat distribution. • Manual Reset capillary type limit provides high temperature regulation and is rated for 6,000 cycles of service. Shown with optional pilot • Stainless steel and aluminum pressure relief valve for overpressure. light and disconnect switch • A back-up contactor is included for additional protection. • 14 gauge steel cabinet powder coated epoxy paint finish contains heater core, motor, and fan assembly. • Narrow gap safety fan guard shields all moving parts. • Adjustable louvers allow directional control of air. • Copper conductor wires enclosed in rigid metal conduits carry all Manufactured in U.S.A. electrical power. • Box lugs furnished for field connections within approved enclosure. Product Specifications Heat Exchanger and Elements: Heavy walled, painted carbon steel with aluminum fins liquid heat exchanger, liquid filled with three-immersion type copper sheathed elements. The elements shall have the highest quality nickel-chromium resistance wire encased in a magnesium oxide dielectric and be hermetically sealed into the heat exchanger core. The heat transfer fluid is Ethylene-glycol solution for operation to -49 degrees F (– 45 degrees C). Stainless steel and aluminum pressure relief valve for overpressure. Thermal Cutout High Limit Protection and Optional Pilot Light: The capillary type manual reset thermal cutout shall be rated for 6000 cycles of service and mounted in the liquid filled heat exchanger. An optional pilot light to indicate manual reset tripped, if safe operating temperatures are exceeded, is located on control enclosure. Motor: The motor shall be a permanent split capacitor type, permanently lubricated, ball bearing type. The motor shall be rated for hazardous location and operate at rated voltage of heater, 60 Hz, 1725 RPM. Control Enclosure: All controls shall be factory installed and wired in a hazardous location enclosure. Contactors and back-up contactors are heavy duty type and break all ungrounded conductors and be rated for 100,000 cycles at full load. Standard 24-Volt control circuit shall be supplied by internal class II transformer. An optional factory wired integral thermostat or standard terminal block for field wiring to optional remote wall thermostat are wired in control panel. No fan delay relay. Disconnect Switch: Factory mounted and wired hazardous location disconnect switch is available as optional accessory. Cabinet With Adjustable Louvers: The Cabinet shall be 14 gauge, cold rolled steel with powder coated epoxy finish. Plated fan guards with less than 1/4 inch spacing to cover motor and fan shall conform to OSHA Requirements. Note: Before selecting a hazardous location electric heater refer to Article 500 or other applicable standard referenced in the National Electric Code. Liquid-to-air heat exchanger Optional built-in thermostat Hazardous Location Rated Motor HLA Series Hazardous Location Fan Forced Unit Heater Rating Definitions CLASS I: Equipment does not have surface operating temperature in excess of the ignition temperature of the specific gas or vapor. Application Examples: • Offshore and land based drilling rigs, petroleum exploration and testing facilities. • Petroleum refineries, gasoline storage and dispensing areas. • Industrial firms that use flammable liquids in dip tanks for parts cleaning or other operations. • Petrochemical companies that manufacture chemicals from gas or oil. • Dry cleaning facilities where vapors from cleaning fluids may be present. • Aircraft hangers and fuel servicing areas. • Utility gas plants and operations involving storage and handling of liquefied petroleum or natural gas. GROUP C: Atmospheres such as but not limited to acetaldehyde, allyl alcohol, hydrogen sulfide, ethylene, carbon monoxide, or other gases or vapors of equivalent hazard. GROUP D: Atmospheres such as but not limited to acetone, alcohol, gasoline, lacquer solvent vapors, natural gas, propane or other gases or vapors of equivalent hazard. CLASS II: Equipment does not have surface temperature greater than the ignition temperature of the specified dust. Application Examples: • Coal preparation plants and other carbon handling or processing areas. • Grain elevators, flour and feed mills. • Plants which manufacture, use or store Magnesium or Aluminum powders. • Plants that have chemical or metallurgical processes. • Producers of starch products or candy. • Spice grinding plants, sugar plants and cocoa plants. GROUP E: Atmosphere containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard characteristics having resistivity of less than 105 OHM - Centimeter. GROUP F: Atmosphere containing carbon black, charcoal, coal or coke dust. GROUP G: Atmospheres containing combustible dust having resistivity of 105 OHM-Centimeter or greater. DIVISION I: A location in which ignitable concentrations of flammable material exist under normal operating conditions. DIVISION II: Locations in which flammable materials will normally be confined within closed containers and escape only in the case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically also approved for Division II. Standard Hazardous Location Models UPC# 686334 MODEL 734356 734004 734011 734028 734035 734363 734059 734066 734073 734080 734370 734103 734110 734127 734134 734158 734165 734172 734189 734202 734219 734226 734233 734240 734257 734264 734271 HLA 12-208160-3.0-24 HLA 12-208360-3.0-24 HLA 12-240160-3.0-24 HLA 12-240360-3.0-24 HLA 12-480360-3.0-24 HLA 12-208160-5.0-24 HLA 12-208360-5.0-24 HLA 12-240160-5.0-24 HLA 12-240360-5.0-24 HLA 12-480360-5.0-24 HLA 12-208160-7.5-24 HLA 12-208360-7.5-24 HLA 12-240160-7.5-24 HLA 12-240360-7.5-24 HLA 12-480360-7.5-24 HLA 16-208360-10.0-24 HLA 16-240160-10.0-24 HLA 16-240360-10.0-24 HLA 16-480360-10.0-24 HLA 20-208360-15.0-24 HLA 20-240360-15.0-24 HLA 20-480360-15.0-24 HLA 20-600360-15.0-24 HLA 20-480360-20.0-24 HLA 20-600360-20.0-24 HLA 20-480360-25.0-24 HLA 20-600360-25.0-24 KW BTU’s 3 10250 5 17100 7.5 25600 10 34150 15 51200 20 68300 25 85400 VOLTS PH AMPS 208 208 240 240 480 208 208 240 240 480 208 208 240 240 480 208 240 240 480 208 240 480 600 480 600 480 600 1 3 1 3 3 1 3 1 3 3 1 3 1 3 3 3 1 3 3 3 3 3 3 3 3 3 3 16.3 9.8 14.8 8.6 4.3 26 15.4 23.1 13.4 6.7 38 22.3 33.6 19.4 9.7 29.3 44 25.5 12.7 43.5 38.1 19 15.2 25.1 20 31.1 24.9 Control Temp Air Voltage Rise °F Throw CFM 16.5 27.6 24’ 580 41.4 Recom’d Mounting Ht. WT. 8’ 167 lb. 8’ 167 lb. 8’ 167 lb. 10’ 193 lb. 24 21.7 40’ 1500 19.2 193 lb. 43’ 2450 13’ 26.2 225 lb. 32.8 5 HLA Series Hazardous Location Fan Forced Unit Heater Mounting Bracket Kits 6 Column stabilizing components Roof or overhead structure Mounting arm assembly Attachment assembly 1/2” Pipe (Not Supplied) HLHM Hanging Mounting Kit Simple and economical if adequate overhead structure exists. Requires 1/2’’ pipe, cut and threaded (not supplied). 3 1/2” Schedule 40 (Pipe) (Not Supplied) Attachment assembly Wall bracket Mounting arm Base assembly Wall or structure HLWM Wall Mounting Kit Ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel. HLPM Pipe Mounting Kit Particularly useful in buildings with insufficient strength to use other types of mounts. Requires 3 1/2’’ pipe (4’’ O.D. not supplied). UPC# 686334 734288 734295 734301 734318 734325 734332 734349 NUMBER HLPM37 HLPM1015 HLPM1525 HLHM HLWM37 HLWM10 HLWM1525 USE WITH HEATERS 3.0 KW - 7.5 KW 10.0 KW 15.0 KW - 25.0 KW ALL 3.0 KW - 7.5 KW 10.0 KW 15.0 KW - 25.0 KW WT. 37 lbs. 38 lbs. 40 lbs. 5 lbs. 27 lbs. 28 lbs. 29 lbs. EPET Series and HLT Series Hazardous Location Thermostats For Single Phase HLT Series • • • • • • • • Features SPDT & DPDT Models Heat or cool compatible Celsius and Fahrenheit temperature scale Bi-Metal or capillary sensor Snap action switch Casting tapped top and bottom for 3/4” conduit 1/2” thick cast aluminum housing Dimension 5.75” x 6.375” x 5.57” Motor Rating (full load): 3/4 HP @ 125V, 1 1/2 HP @250V Pilot Duty Rating 125VA @ 24VAC NEMA Class Seven Div. 1 Approved Class I Group C & D, Class II Group E, F, & G Not rated for Group B UPC# 686334 MODEL DESCRIPTION LOAD RATINGS RANGE 538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF 538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF 528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF 528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF 523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110oF 523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110oF Master ctn: 4 pcs, 24 llbs (varies slightly by model), 16” x 14.5” x 6” EPET Series incorporate plastic knob & Bi-Metal Sensor housing. HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb and capillary sensor. HLA Series Hazardous Location Fan Forced Unit Heater Factory Installed Accessories & Physical Dimensions 7 (Top View) SUFFIX DESCRIPTION T In-Built single pole thermostat 50° - 90° F 120 Control transformer w/ primary fusing (Delete 24 suffix - add 120) 208 240 208/240V Control available on 208/240V units (Delete 24 suffix and add 208 OR 240) D Disconnect Switch P Pilot Light MODEL A B C G HLA 12 17 3/4 22 3/8 19 3/4 20 5/8 16 1/4 10 1/2 14 3 HLA 16 20 3/4 26 3/8 20 3/4 21 5/8 20 1/4 11 1/2 18 4 N/A 24 1/4 12 1/2 22 4 1/2 HLA 20 24 3/4 30 3/8 22 1/2 1 ph. E (Rear View) F 3 ph. D (Front View) (Side View) PHLA Series Portable Hazardous Location Fan Forced Unit Heater • • • • • • • • • • • 3.0 through 25 KW rating 208, 240, 480, 600 Volt available in selected capacities Cart has anti-static wheels to reduce the risk of static discharge Wheeled cart allows for easy maneuverability Cart has integrated fork-lift channels to provide ease of lifting on to ramps or trucks Excellent for providing seasonal heating in hazardous environments All units have disconnect switch, pilot light, and thermostat - standard 24 Volt control, transformer, and contactor in NEMA 7 enclosure Durable epoxy coating on heater housing Hazardous location unit mounted male / female plug Adjustable louvers; manual reset Standard Portable Hazardous Location Models UPC # 686334 739344 739337 739320 739313 739306 739436 739290 739283 739276 739269 739252 739429 739245 739238 739221 739214 739207 739412 739191 739184 739177 739160 739405 739153 739146 739139 739399 739122 739382 739115 739375 MODEL PHLA12-208160-3.0-24-TDP PHLA12-208360-3.0-24-TDP PHLA12-240160-3.0-24-TDP PHLA12-240360-3.0-24-TDP PHLA12-480360-3.0-24-TDP PHLA12-600360-3.0-24-TDP PHLA12-208160-5.0-24-TDP PHLA12-208360-5.0-24-TDP PHLA12-240160-5.0-24-TDP PHLA12-240360-5.0-24-TDP PHLA12-480360-5.0-24-TDP PHLA12-600360-5.0-24-TDP PHLA12-208160-7.5-24-TDP PHLA12-208360-7.5-24-TDP PHLA12-240160-7.5-24-TDP PHLA12-240360-7.5-24-TDP PHLA12-480360-7.5-24-TDP PHLA12-600360-7.5-24-TDP PHLA16-208360-10.0-24-TDP PHLA16-240160-10.0-24-TDP PHLA16-240360-10.0-24-TDP PHLA16-480360-10.0-24-TDP PHLA16-600360-10.0-24-TDP PHLA20-208360-15.0-24-TDP PHLA20-240360-15.0-24-TDP PHLA20-480360-15.0-24-TDP PHLA20-600360-15.0-24-TDP PHLA20-480360-20.0-24-TDP PHLA20-600360-20.0-24-TDP PHLA20-480360-25.0-24-TDP PHLA20-600360-25.0-24-TDP KW BTU 3 10,250 5 17,100 7.5 25,600 10 34,150 15 51,200 20 68,300 25 85,400 VOLTS PH AMPS 208 208 240 240 480 600 208 208 240 240 480 600 208 208 240 240 480 600 208 240 240 480 600 208 240 480 600 480 600 480 600 1 3 1 3 3 3 1 3 1 3 3 3 1 3 1 3 3 3 3 1 3 3 3 3 3 3 3 3 3 3 3 16.3 9.8 14.8 8.6 4.3 3.5 26 15.4 23.1 13.4 6.7 5.4 38 22.3 33.6 19.4 9.7 7.8 29.3 44 25.5 12.7 10.2 43.5 38.1 19 15.2 25.1 20 31.1 24.9 TEMP RISE F AIR THROW CFM WT 16.5 24’ 580 260 27.6 24’ 580 260 41.4 24’ 580 260 21.7 40’ 1500 305 19.2 43’ 2450 350 26.2 43’ 2450 350 32.8 43’ 2450 350 FEP Series Single Phase Hazardous Location Wall Convector T-2A SERIES SINGLE PHASE Class 1, Group B, C & D Division 1 & 2 280° C / 536° F 8 UPC MODEL 686334 445146 445153 445160 445177 445184 445191 445207 445214 445221 445238 445245 445252 445269 445276 445283* 445290* 445306* 445313 445320 Standard Unit Unit with optional control section containing disconnect, pilot light, and thermostat (Suffix C1-TDP) FEP-1812-1RA FEP-1820-1RA FEP-1824-1RA FEP-1827-1RA FEP-1848-1RA FEP-3620-1RA FEP-3624-1RA FEP-3627-1RA FEP-3648-1RA FEP-3657-1RA FEP-3820-1RA FEP-3824-1RA FEP-38271-RA FEP-3848-1RA FEP-7620-1RA FEP-7624-1RA FEP-7627-1RA FEP-7648-1RA FEP-7657-1RA WATTS BTU's 1800 6143 3600 12286 3800 12969 7600 25938 VOLTS AMPS 120 208 240 277 480 208 240 277 480 600 208 240 277 480 208 240 277 480 600 15.0 8.7 7.5 6.5 3.8 17.3 15.0 13.0 7.5 6.0 18.3 15.8 13.7 7.9 36.5 31.7 27.4 15.8 12.7 *Items may not be used with 22 Amp line voltage thermostat CABINET LENGTH WT. (LBS.) 34” 50 34” 54 58” 80 58” 85 34” 50 34” 54 58” 80 58” 85 T-3A SERIES SINGLE PHASE Class 1, Group B, C & D Division 1 & 2 180° C / 356° F Unit with in-built EPET line voltage thermostat (Suffix T1 or T2) Manufactured in U.S.A. • Cabinet size 18” high, 9” wide. • Bottom In - Front Out air flow. • Wall mounting bracket supplied. • Units cannot be operated in room ambients exceeding 104OF (40OC). • Heavy duty 16 gauge steel with gray epoxy textured powder coated finish. • 9” minimum clearance from bottom of heater to floor required. • Stainless steel cartridge element inserted into Aluminum finned Copper sheath. • Standard unit (without EPET thermostat or control section) is NEMA 4 rated. 445337 445344 445351 445368 445375 445382 445399 445405 445412 445429 445436 445443 445450 445467 445474 445481 445498 445504 445511 445528 445535 FEP-0812-1RA FEP-0820-1RA FEP-0824-1RA FEP-0827-1RA FEP-0848-1RA FEP-1612-1RA FEP-1620-1RA FEP-1624-1RA FEP-1627-1RA FEP-1648-1RA FEP-1657-1RA FEP-1712-1RA FEP-1720-1RA FEP-1724-1RA FEP-1727-1RA FEP-1748-1RA FEP-3420-1RA FEP-3424-1RA FEP-3427-1RA FEP-3448-1RA FEP-3457-1RA 800 2730 1600 5460 1700 5802 3400 11604 120 208 240 277 480 120 208 240 277 480 600 120 208 240 277 480 208 240 277 480 600 6.7 3.8 3.3 2.9 1.7 13.3 7.7 6.7 5.8 3.3 2.7 14.2 8.2 7.1 6.1 3.5 16.3 14.2 12.3 7.1 5.7 Factory Installed Control Options SUFFIX* DESCRIPTION SUFFIX** DESCRIPTION T1 EPETD8S single pole thermostat factory mounted to 120V - 480V units C1-TD Control section with transformer, 24V contactor, SP thermostat (40OF - 90OF) and disconnect switch (all units) T2 EPETD8D double pole thermostat factory mounted to 120V - 480V units C1-TDP Control section with transformer, 24V contactor, SP thermostat (40OF - 90OF), disconnect switch & pilot light (all units) *Remove - RA suffix and add new suffix. **Remove - RA suffix and add new suffix (Not NEMA washdown rated or rated for Group B atmospheres) Suffix “T” is 22 Amps maximum. FEP Series Three Phase Hazardous Location Wall Convector • Cabinet size 18” high, 9” wide. • ABS (American Bureau of Shipping) type approved. • Bottom In - Top Out air flow. • Wall mounting bracket supplied. O O • Units can not be operated in room ambients exceeding 104 F (40 C). • Heavy duty 16 gauge steel with gray epoxy textured powder coated finish. • 9” minimum clearance from bottom of heater to floor required. • Stainless steel cartridge element inserted into Aluminum finned Copper sheath. • Standard unit (without EPET thermostat or control section) is NEMA 4 rated. 9 T-2A SERIES THREE PHASE Class 1, Group B, C, & D Divisions 1 & 2 280° C / 536° F UPC 686334 483056 483063 486224 483070 483087 486231 483094 483100 486248 483117 483124 486255 MODEL WATTS BTU's 1800 6143 3600 12286 3800 12969 7600 25938 FEP-1820-3RA FEP-1824-3RA FEP-1848-3RA FEP-3620-3RA FEP-3624-3RA FEP-3648-3RA FEP-3820-3RA FEP-3824-3RA FEP3848-3RA FEP-7620-3RA FEP-7624-3RA FEP-7648-3RA VOLTS AMPS 208 240 480 208 240 480 208 240 480 208 240 480 5.0 4.3 2.2 10.0 8.7 4.3 10.5 9.1 4.6 21.1 18.3 9.2 CABINET LENGTH WT. (LBS.) 34” 50 34” 54 58” 80 58” 85 34” 50 34” 54 58” 80 58” 85 Standard Unit T-3A SERIES THREE PHASE Class 1, Group B, C & D Division 1 & 2 180° C / 356° F 483131 FEP-0820-3RA 483148 FEP-0824-3RA 208 2.2 240 1.9 486262 FEP-0848-3RA 480 0.9 483155 FEP-1620-3RA 483162 FEP-1624-3RA 208 4.4 240 486279 FEP-1648-3RA 3.8 480 1.9 483179 FEP-1720-3RA 483186 FEP-1724-3RA 208 4.7 240 4.1 486286 483193 FEP-1748-3RA 480 2.0 FEP-3420-3RA 208 483209 FEP-3424-3RA 9.4 240 486293 FEP-3448-3RA 8.2 480 4.1 800 1600 1700 3400 2730 5460 5802 11604 *T1 and T2 option not available on 3 phase models Unit with optional control section containing disconnect, pilot light, and thermostat (Suffix C1-TDP) Note: Controls mounted on the left side only. Factory Installed Control Options SUFFIX** DESCRIPTION C1-TD Control section with transformer, 24V contactor, SP thermostat (40OF - 90OF) and disconnect switch (all units) C1-TDP Control section with transformer, 24V contactor, SP thermostat (40OF - 90OF), disconnect switch & pilot light (all units) Note: C1-TD and C1-TDP are only options available for 3 phase units. **Remove - RA suffix and add new suffix (Not NEMA washdown rated or rated for Group B atmospheres) Remote Mounted Hazardous Location Thermostats For Single Phase Models Only HLT Series UPC# 686334 MODEL DESCRIPTION LOAD RATINGS RANGE 538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF 538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF 528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF 528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF 523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110oF 523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110oF Master ctn: 4 pcs, 24 lbs (varies slightly by model), 16” x 14.5” x 6” EPET Series incorporates plastic knob & Bi-Metal Sensor housing. HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb and capillary sensor. EPET Series Parameters Dimensions: Finish: Type: Height 5 5/8’’, Width 6 3/8’’, Depth 4 1/2’’ Silver-Gray Single or Double Pole Motor Rating: (full load) 1 1/2 HP @ 250V Rating: 22A @ 125-277VAC; 125VA @ 24VAC Rated: Class I Group C & D, Class II Group E, F, G Thermostat is not rated for use in Group B environments. WD Series Washdown Fan Forced Unit Heater The Washdown Series unit heaters are electric unit heaters constructed for use in areas that require washing or hosing of equipment due to dirty or dusty industrial environments in non-hazardous locations. The totally enclosed water-tight construction made with corrosion-resistant material make this series ideal for industrial heating applications. The Washdown Series is constructed with all built-in controls and safety temperature controls wired in a non-metallic Nema 4x control panel with single-point power connections. 10 Rear View • Stainless steel finned tubular element. Constructed of 304 or 316 stainless rod and fins. • Control panel on bottom of unit for ease of installation and service. • Disconnect switch with enclosure door interlock. • Front grill rotates to direct airflow. • Single-point power connection. • Fan Blade Epoxy coated Aluminum. • Epoxy painted cold roll steel model available - consult factory. • Meets all U.L., NEC, and OSHA requirements (when installed as directed). • Corrosion-resistant in high humidity and water-saturated areas (for areas where corrosion resistance is needed in non-explosive areas, contact factory for heater applications and optional materials). • ABS (American Bureau of Shipping) type approved. • Thermostat temp range: 40o-100oF • • • • • • • • • Control Panel Manufactured in U.S.A. Heavy-duty 304 16 gauge stainless steel shroud. 316 stainless construction available. Nema 4x non-metallic control panel. 24-Volt transformer and control panel. 3-position switch (off-heat-fan). Capillary thermostat with stainless steel sensor. Automatic reset thermal cutout. Totally enclosed U.L. listed motor. Pilot light (power on indicator). Mounting Bracket Kits & Product Dimensions SIZE KW UPC# 686334 STAINLESS STEEL COMBINATION BRACKET UPC# 686334 WALL MTG. BRACKET * UPC# 686334 HANGING BRACKET * UPC# 686334 PIPE MTG. BRACKET * 3.3-15 725729 A5520/UHB 713726 W5520/WMK 713702 H5520/HMK 713689 P5520/PMK ---- 713733 W5550/WMK 713719 H5550/HMK 713696 P5550/PMK 20-48 * Material: Heavy Duty Epoxy Powder Coat Finish. Ideal for use in buildings that have substantial walls. Arm (only) can be bolted directly to structural steel. WALL BRACKET Particularly useful in buildings with insufficient strenth to use other types of mounts. Requires 3 1/2" pipe (4" O.D.-not supplied). Simple and economical if adequate overhead structure exists. Requires 1/2" pipe, cut and threaded (not supplied). ROOF OR OVERHEAD STRUCTURE COLUMN STABILIZING COMPONENETS MOUNTING ARM ASSY. MOUNTING ARM 1/2" PIPE (NOT SUPPLIED) BASE ASSEMBLY 3 1/2" SCHEDULE 40 PIPE (NOT SUPPLIED) 3-15 Kw ONLY WALL OR STRUCTURE A5520 H W5550 G H5550 A FIG. 1 P5550 E C FIG. 2 D B FIG. 3 F Heater Dimension in Inches unless otherwise stated. Heater KW A B C D E F G H 3-7.5 12.00 18.00 19.75 15.25 16.25 8.00 6.00 10-15 14.00 19.00 21.75 15.25 18.00 8.00 6.00 20-30 16.00 27.00 28.75 19.50 17.50 15.50 4.50 40-48 18.00 31.00 30.75 19.50 19.50 21.75 2.75 6 ft. WD Series Washdown Fan Forced Unit Heater Product Specifications & Standard Washdown Models Enclosure and Motor: Element housing shall be 16 gauge 304 or 316 stainless steel shroud. The outlet grill and louver assembly shall be 304/316 stainless steel and rotate for direction of discharge air. The heater shall have a 304/316 stainless steel inlet grill and fan guard. The motor shall be totally enclosed, permanently lubricated and designed to resist moisture and corrosion. The fan blade shall be aluminum with a powder coated epoxy finish. Element: The heating element shall be 304 or 316 stainless steel tube with 304/316 stainless steel fin material helically attached to the tube for even heat transfer. The element designed with the highest quality nickelchromium resistance wire embedded in compacted efficient dielectric to ensure proper heat transfer. Control Panel: The control enclosure shall be non-metallic Nema 4X control panel watertight and dust- tight. The enclosure and elements are attached to the control panel with stainless steel fasteners. Standard control components are factory mounted and wired with access through control panel door on bottom of heater assembly. A standard door interlock disconnect switch shall be factory mounted and wired for safety. Controls: All controls shall be factory mounted and wired in Nema 4X panel. Terminal block, 24 Volt transformer, high temperature limits, contactor and fusing if required by NEC are mounted and wired in control panel. A three-position switch (OffHeat-Fan) shall be mounted on side of control panel for access from outside of panel. A pilot light to indicate power is on for safety shall be located on side of control panel. A wall mounted Nema 4X thermostat is an optional accessory. Mounting Bracket: A formed 304/316 stainless steel bracket shall be used on 3.3 thru 15 KW units. A cast iron epoxy painted bracket shall be used on 20 thru 48 KW units. Above brackets shall be combination wall/ceiling type. Optional mounting brackets are available. UPC# 686334 MODEL 713047 713054 713061 21WD3T01 713078 22WD3T01 713085 713092 KW VOLTS PH AMPS 81WD3T01 208 1 15.9 82WD3T01 208 3 9.2 240 1 13.7 240 3 7.9 71WD3T01 277 1 11.9 43WD3T01 480 3 4 3.3 BTU’s 11200 713115 81WD5T01 208 1 24.1 713122 82WD5T01 208 3 13.9 713139 21WD5T01 240 1 20.8 713146 22WD5T01 240 3 12.1 713153 71WD5T01 277 1 18.1 713160 43WD5T01 480 3 6.1 713184 81WD7T01 208 1 36.1 713191 82WD7T01 208 3 20.8 713207 21WD7T01 240 1 31.3 713214 22WD7T01 240 3 13.1 713221 71WD7T01 277 1 27.1 713238 43WD7T01 480 3 9.1 713252 81WD10T01 208 1 47.8 713269 82WD10T01 208 3 27.7 713276 21WD10T01 240 1 41.2 713283 22WD10T01 240 3 24.1 713290 71WD10T01 277 1 36.1 713306 43WD10T01 480 3 12.1 713399 81WD15T01 208 1 72.1 713405 82WD15T01 208 3 41.7 713412 21WD15T01 240 1 62.5 713429 22WD15T01 240 3 36.1 713443 43WD15T01 480 3 18.1 5 7.5 10 15 713467 83WD20T01 713474 23WD20T01 713481 713504 713511 23WD25T01 713528 713542 713559 23WD30T01 713566 43WD30T01 713603 43WD40T01 40 713641 43WD48T01 48 17100 25600 34130 51200 CONTROL TEMP AIR CFM VOLTAGE RISE °F THROW 26 40 55.6 48.2 43WD20T01 480 3 24.1 83WD25T01 208 3 69.5 240 3 60.2 43WD25T01 480 3 30.1 83WD30T01 208 3 83.4 240 3 72.3 480 3 36.1 136520 480 3 48.2 70 163824 480 3 57.8 84 30 102390 28’ 700 64 35’ 1400 92 42’ 1800 126 68 3 85325 58 45 3 25 400 24 208 68260 20’ 60 240 20 WT. (LBS.) 45 56 68 Remote Rain-Tight Thermostat UPC# 686334 MODEL DESCRIPTION 523424 TW155A 1 POLE, 40-110 deg F, 22Amp 523431 TW255A 2 POLE, 40-110 deg F, 22Amp Note: NEMA 4X Construction Stainless Steel Hardware Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges. 11 UH Series Horizontal Fan Forced Unit Heater 12 3.3 KW THROUGH 48 KW HORIZONTAL DISCHARGE SUSPENDED FAN FORCED UNIT HEATERS AVAILABLE IN 1 OR 3 PHASE FOR ALL STANDARD VOLTAGES FROM 208V TO 480V. Manufactured in U.S.A. NOTE: Louver assembly is square and mounted with screws. Louver can be removed and repositioned for four (4) directional air flow - left - right - up - down with the heater in the horizontal position. FACTORY INSTALLED OPTIONS: • 24 Volt transformer on 3 KW to 15KW units to convert from line voltage to low voltage remote thermostat operation. • Summer fan switch to operate the fan only. • Fan delay switch to purge all residual heat from the unit after the heating element has cycled off. • Powder coated epoxy finish for corrosive atmospheres. • Disconnect switch. MAXIMUM RECOMMENDED MOUNTING HEIGHT 3 - 10 KW 12 - 15 KW 20 - 30 KW 40 - 48 KW 9 FT. 10 FT. 13 FT. 16 FT. CONSTRUCTION: Heavy gauge welded steel cabinet with powder coated finish and control compartment with a hinged and latched access door, simplifying wiring installation & maintenance. HEATING ELEMENT: Circular copper clad steel sheath element with continuously brazed steel fins formed to match the air delivery pattern of the fan blade. OVERHEAT PROTECTION: All units come equipped with automatic resetting type limit controls to deenergize the heater should an over-temperature situation occur. FAN and MOTOR: Totally enclosed, single phase, permanently lubricated, thermally protected motors with unit bearings on 3 KW - 10 KW models and sleeve bearings on 12.5 KW - 48 KW models - mounted with rubber insulators to minimize vibration and noise. Fan assembly enclosed by a heavy gauge, close spaced, chrome plated wire guard. LOUVER ASSEMBLY: Louvers are individually adjustable for directional control of air flow and the entire assembly can be repositioned in the field from down flow to up flow or left / right directional air flow. TEMPERATURE CONTROLS: 20 KW through 48 KW units and all 480V have built in 24 Volt transformer for low voltage remote thermostat application. 25 KW through 48 KW models available in 2-stage on special order (consult factory). INSTALLATION: Unit Heaters can be mounted with the motor shaft from horizontal to downward at 45° off horizontal. Pre-drilled holes and installed threaded nuts provided to allow hanging by threaded rods - 1/4” for units up to 15 KW and 5/16” for 20 KW units and larger. Optional wall / ceiling mounting brackets are available for all units. Product Dimensions & Model Number Designation Dimensions Figure 1: A 3.3, 5, 7.5, 10 KW A Figure 2: B B B 3.3 KW THROUGH 15 KW UNIT HEATERS 20, 25, 30 KW A Figure 4: 40, 48 KW 20 KW THROUGH 48 KW UNIT HEATERS C 20” 11” 13” 22” 11” 15” 12.5, 15 KW Figure 3: A B 24” 17” 17” 26” 23” 19” Figures 3 & 4 shown with standard mounting tabs for units over 20 KW. Optional UHB-3 and UHB-4 wall brackets are available. 3.3 KW thru 15 KW units can be mounted using 1/4” threaded rod. 20 KW thru 48 KW units can be mounted using 5/16” threaded rod. HOW TO DESIGNATE A MODEL: H Element Volts F = 208 H = 240 HF = 240/208 G = 277 P = 480 Phase 1 = 1-Phase 2 = 1 or 3-Ph. 3 = 3-Phase 2 Motor Voltage F = 208 H = 240 B = 240 / 208 G = 277 P = 480 H Model Series UH UH 10 Element KW C A Control System Transformer O = None O = None C = Contactor A = Included R = Relay Factory Installed Options (use as a suffix on model designation): S = Summer Fan Switch, F = Fan Delay, D = Disconnect, T = Built-in Thermostat, E = Epoxy Coated Field Installed Options: Disconnect Switch, Built-in Thermostat, & Wall / Ceiling Bracket 1 Control Volts 1 = 24 2 = 120 3 = Element Voltage 4 = 240 UH Series Horizontal Fan Forced Unit Heater Standard Product Models UPC# 686334 MODEL 644600 644662 644723 711487 711494 711401 644617 644679 644730 644938 644945 644884 644624 688550 644747 644792 644952 644891 644631 644693 644754 644969 F1FUH03003 H1HUH03003 G1GUH03003 H3HUH03C03 F3FUH03C03 P3PUH03CA1 F1FUH05003 H1HUH05003 G1GUH05003 F2FUH05C03 H2HUH05C03 P3PUH05CA1 F1FUH07CA1 H1HUH07CA1 G1GUH07CA1 F3FUH07C03 H2HUH07C03 P3PUH07CA1 F1FUH10CA1 HIHUH10CA1 G1GUH10CA1 F2FUH10C03 644976 HF2HUH10C03 10/7.5 711425 644648 644709 644815 644860 711432 644655 644716 644822 644877 711449 688307 688420 688314 688437 688321 688444 688338 688451 688345 688468 688475 688369 688482 688376 688406 688789 P3PUH10CA1 F1FUH12C03 H1HUH12C03 F3FUH12C03 H3HUH12C03 P3PUH12CA1 F1FUH15CO3 H1HUH15C03 F3FUH15C03 H3HUH15C03 P3PUH15CA1 F1FUH20CA1 H1HUH20CA1 F3FUH20CA1 H3HUH20CA1 P3PUH20CA1 F1FUH25CA1 H1HUH25CA1 F3FUH25CA1 H3HUH25CA1 P3PUH25CA1 H1HUH30CA1 F3FUH30CA1 H3HUH30CA1 P3PUH30CA1 P3PUH40CA1 P3PUH48CA1 10 34,100 25,600 34,100 12.5 42,600 KW 3.3 5 7.5 10 BTU'S 11,200 17,100 25,600 34,100 15 51,200 20 68,300 25 85,300 30 102,390 40 48 136,500 163,800 VOLTS PH AMPS CONTROL VOLTS 208 240 277 240 208 480 208 240 277 208 240 480 208 240 277 208 240 480 208 240 277 208 240 208 480 208 240 208 240 480 208 240 208 240 480 208 240 208 240 480 208 240 208 240 480 240 208 240 480 480 480 1 1 1 3 3 3 1 1 1 1 or 3 1 or 3 3 1 1 1 3 1 or 3 3 1 1 1 1 or 3 1 or 3 1 or 3 3 1 1 3 3 3 1 1 3 3 3 1 1 3 3 3 1 1 3 3 3 1 3 3 3 3 3 16 14 12 8 9 4 24 21 18 24.1/14.0 20.8/12.1 6 36 31 27 21 31.3/18.1 9 48 42 36 48.1/27.8 41.7/24.1 36.1/20.8 12 60 52 35 30 15 72 63 42 36 18 96 83 56 48 24 120 104 70 60 30 125 83 72 36 48 58 208 240 277 240 208 24 208 240 277 208 240 24 24 24 24 208 240 24 24 24 24 208 240 208 24 208 240 208 240 24 208 240 208 240 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 TEMP RISE °F AIR THROW CFM 26 26' 400 RECOM'D MOUNTING HT. WT. (LBS.) 36 36 40 26' 400 44 9' 42 36' 575 44 55 42 36' 575 55 42 55 49 45 51 45' 800 45 10' 59 45' 800 54 47 56' 1350 55 58 56' 1350 70 56' 1350 55 67 56' 56' 2275 2275 13' F S CA1 CA2 E T D FACTORY INSTALLED OPTIONS DESCRIPTION Heat purge fan delay switch for 208 / 240 / 277V units (includes contactor & transformer) Heat purge fan delay switch for 480V units (contactor & transformer standard in unit) Summer fan switch 24V Transformer (3.3 KW - 15 KW units) & Contactor 120V Transformer (3.3 KW - 15 KW units) & Contactor Epoxy Coating SPST Thermostat Disconnect Switch - 30 Amps Disconnect Switch - 40 Amps Disconnect Switch - 80 Amps Disconnect Switch - 100 Amps 16' FIELD INSTALLED ACCESSORIES UPC# 686334 646239 646246 646253 646260 687997 699105 699112 699129 55 60 Factory & Field Installed Accessories SUFFIX 40 41 41 MODEL DESCRIPTION DCS303 DCS403 DCS803 DCS1003 TUH1 UHB-1 UHB-3 UHB-4 30 Amp Disconnect Kit 40 Amp Disconnect Kit 80 Amp Disconnect Kit 100 Amp Disconnect Kit 25 Amp SPST Thermostat Kit wall / ceiling bracket - 3.3 KW - 15 KW units wall / ceiling bracket - 20 KW - 30 KW units wall / ceiling bracket - 35 KW - 48 KW units NOTE: Factory installed heat purge fan delay option (F) requires unit to have CA1 or CA2 factory installed 75 78 13 5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater 14 3.3 KW THROUGH 50 KW SUSPENDED FAN FORCED UNIT HEATERS AVAILABLE IN 1 OR 3 PHASE FOR ALL STANDARD VOLTAGES FROM 208V TO 480V THAT CAN BE MOUNTED TO PROVIDE HORIZONTAL OR VERTICAL DISCHARGE. CONSTRUCTION: Heavy 18 gauge welded steel cabinet with powder coated finish and control compartment housing a master terminal board with a hinged and latched access door, simplifying wiring, installation & maintenance. Taskmaster Dimensions HEATING ELEMENT: Copper clad steel sheath element with continuously brazed steel fins formed to allow side draw through air flow. OVERHEAT PROTECTION: All units come equipped with automatic reset type limit controls to de-energize the heater should an over-temperature situation occur. Horizontal Discharge Vertical Discharge Manufactured in U.S.A. FIELD INSTALLED OPTIONS: • In-unit or wall mounted temperature control thermostats low or line voltage. • Summer fan switch to operate the fan only. • Power disconnect switch. • Heat stratification thermostat. KW RATING H W D 3.3 - 5.0 17 3/4 14 15/32 6 1/2 7.5 - 10.0 24 5/16 21 1/2 6 1/2 15.0 - 20.0 28 11/16 21 1/2 6 1/2 25.0 - 50.0 29 1/4 10 1/16 H W D DIMENSIONS (inches) 34 FAN and MOTOR: Totally enclosed, 1-speed, 1-phase, permanently lubricated, thermally protected motors with unit bearings on 3 KW - 20 KW models. Totally enclosed, 2-speed, 1-phase, permanently lubricated, thermally protected motors with sleeve bearings on 25 KW - 50 KW models. All motors mounted with rubber insulators to minimize vibration & noise. Fan over-ride purges unit of residual heat at shutdown. LOUVER ASSEMBLY: Louvers are individually adjustable for directional control of air flow up to 15° from straight horizontal. Optional diffusers available for down flow (vertical discharge) applications. TEMPERATURE CONTROLS: Optional low voltage and line voltage thermostats available with an adjustable temperature range of 40°F to 90°F. Units with model numbers ending in CA1 are factory wired for low voltage controls. 25 KW through 50 KW units are designed for two stage heating operation. INSTALLATION: Unit Heaters can be mounted for horizontal or vertical discharge. Applications up to 6000 Ft. See UH Series above 6000 Ft. ABS (American Bureau of Shipping) type approved. Installing the Taskmaster Series DETERMINING HEATER REQUIREMENTS Calculate the heating loads using the NEMA handbook or ASHRAE guide. Then determine the quantity and size of unit heaters to be used. To maintain uniform heat and reduce stratified air, it is recommended that the total CFM of the units turn the air over approximately 3 times per hour. In instances where a large group of people are located and normally in the same area, use a large number of lower KW unit heaters. In warehouse areas or storage rooms where heat distribution and constant temperatures are less important, use fewer heaters of higher capacity. HORIZONTAL MOUNT Small rooms can be heated by one unit heater. Where two walls are exposed, heaters should be mounted as shown in Figure A. In larger rooms, units should he located so their air streams wipe exposed walls without blowing at them. Units should be located so that the air stream of one supports that of another thus setting up a circulatory air movement shown in Figure B. (Distance between units to be approximately 1-1/2 times published air throw.) Units should not be mounted horizontally in areas having ceiling heights in excess of 15-18 ft. VERTICAL MOUNT Units should be mounted vertically in high bay areas, or where heater location would not interfere with plant operation or traffic, Heaters should be situated to provide free air circulation. Size and selection of units should be based on recommended mounting height. Optional diffusers may best be employed to reduce high air velocity and at the same time disperse heated air in a uniform pattern. When unit heaters are used to combat cold air inrush from opened loading dock doors, one or more units should be arranged to blow warm air across opening (Figure C). DUAL MOUNTING Where square footage is large and comfort essential, both horizontal and vertical installations may best serve your requirements as Figure D demonstrates. Note: Products in this section with factory installed controls are subject to 100% cancellation/restocking charges. 5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater Diffuser Options UPC# MODEL MAX MOUNTING KW USED 686334 NUMBER HEIGHT (ft.) DESCRIPTION 1 Louver Diffuser (Standard). Louvers can be individually adjusted for rectangular coverage over doorways as an air curtain, or to meet rectangular floor pattern heating requirements. 2 General Distribution (No Diffuser). The 5100 air chute venturi permits general down flow air pattern distribution as required at a higher mounting height. NA Not Required 3.3-5 7.5-10 25-30 40-50 3 Anemostat Diffuser (Optional). For applications where draft restriction is required at lower unit mounting heights. 692687 681186 681186 722070 AD5120 AD5150 AD5150 AD5175 7.5-10 25-30 40-50 60-70 4 Radial Diffuser (Optional). Individually adjustable fins permit increased floor coverage at 45° open. Additional throw is accomplished when fins are 90° vertical. (Please allow for higher mounting heights.) NA 692663 692663 692670 692670 722087 DIMENSION A (feet) DIMENSION B (feet) WT. (lbs.) Standard 3.3-5 7.5-10 25-30 40-50 9 12 18 22 24 20 40 52 75 84 10 22 30 42 47 NA 9 12 18 22 24 15 30 40 55 64 NA NA 15 17 20 31 38 50 60 - RD5120 RD5120 RD5150 RD5150 RD5175 45° 10 14 20 18 26 7.5-20 25-50 60-70 90° 14 21 30 28 36 45° 36 42 62 68 72 10 NA 12 37 90° 30 35 44 54 60 12 14 NA 39 Description 1 Description 2 Description 3 Louver Diffuser Description 4 No Diffuser Anemostat Diffuser Radial Diffuser Mounting Brackets & Model Designator (*Included with A5100 bracket.) Not actual colors. Red & yellow shading is for diagram clarity only. MOUNTING BRACKETS UPC# MODEL MODEL SIZE 686334 692694 A5105 3.3 KW TO 5.0 KW 692700 A5120 7.5 KW TO 20.0 KW 692717 A5150 25.0 KW TO 50.0 KW 688628 B5105* 3.3 KW TO 20.0 KW 688635 B5150* 25.0 KW TO 50.0 KW 692847 V5105 3.3 KW TO 5.0 KW 692854 V5120 7.5 KW TO 20.0 KW 692861 V5150 25.0 KW TO 50.0 KW DUST SHIELD 692878 DS5105 3.3 KW TO 5.0 KW 692885 DS5120 7.5 KW TO 20.0 KW 681223 DS5150 25.0 KW TO 50.0 KW FAN GUARD 706544 OFG5101 3.3 KW TO 5.0 KW 706551 OFG5102 7.5 KW TO 20.0 KW 706568 OFG5103 25.0 KW TO 50.0 KW WT. 9 lbs. 13 lbs. 16 lbs. 3 lbs. 8 lbs. 9 lbs. 13 lbs. 16 lbs. 3 lbs. 4 lbs. 5 lbs. 3 lbs. 4 lbs. 5 lbs. HOW TO DESIGNATE A MODEL: HF Element Volts F = 208 H = 240 HF = 240/208 G = 277 P = 480 Phase 1 = 1-Phase 2 = 1 or 3-Ph. 3 = 3-Phase 2 Motor Voltage F = 208 H = 240 B = 240 / 208 G = 277 P = 480 B Model Series 51 51 10 Element KW C A 1 Control System Transformer Blank = None Blank = None C = Contactor A = Included Control Volts 1 = 24 2 = 120 (with CA option) 15 5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater 16 Standard Taskmaster Models & Series Notes UPC# 686334 MODEL KW BTU / H VOLTS 645089 645102 645683 F1F5103N HF1B5103N F2F5103N 3.3 3.3/2.5 3.3 11.2 11.2 / 8.5 11.2 208 240/208 208 645706 HF2B5103N 3.3/2.5 11.2 / 8.5 240/208 645720 645126 645546 645560 G1G5103N P3P5103CA1N F1F5105N HF1B5105N 3.3 11.2 5.0 5.0/3.7 17.1 17.1 / 12.8 277 480 208 240/208 645140 F2F5105N 5.0 17.1 208 645164 HF2B5105N 645843 645188 645201 G1G5105N P3P5105CA1N F2F5107CA1L 645225 HF2B5107CA1L 645928 645249 645263 G1G5107CA1L P3P5107CA1N F2F5110CA1L 645287 HF2B5110CA1L 645645 645300 645324 645348 645362 645386 645409 645881 645942 645980 645423 645447 645461 644044 644068 644082 645485 645508 645522 G1G5110CA1N P3P5110CA1N F3F5115CA1L HF3B5115CA1L P3P5115CA1N HF3B5120CA1L P3P5120CA1N F3F5125CA1L HF3B5125CA1L P3P5125CA1N F3F5130CA1L HF3B5130CA1L P3P5130CA1N F3F5140CA1L HF3B5140CA1L P3P5140CA1N F3F5150CA1L HF3B5150CA1L P3P5150CA1N 5.0 3.7 5.0 5.0 7.5 7.5 5.6 7.5 7.5 9.9 10.0 7.5 10.0 10.0 15.0 15.0/11.2 15.0 19.7/14.8 20.0 25.0 25.0/18.7 25.0 30.0 30.0/22.5 30.0 40.0 40.0/30.0 39.0 49.6 50.0/37.5 50.0 17.1 12.8 17.1 17.1 25.6 25.6 19.2 25.6 25.6 33.8 34.1 25.6 34.1 34.1 51.2 51.2 / 38.4 51.2 67.2 / 50.5 68.3 85.3 85.3 / 64.0 85.3 102.4 102.4 / 76.8 102.4 136.5 136.5/102.4 133.1 169.3 170.6/128.0 170.6 240 208 277 480 208 240 208 277 480 208 240 208 277 480 208 240/208 480 240/208 480 208 240/208 480 208 240/208 480 208 240/208 480 208 240/208 480 PH AMPS 1 15.9 1 13.7 / 11.9 1/3 11.9 / 6.9 1 / 3 13.7 / 11.9 3 7.9 / 6.9 1 11.9 3 4.0 1 24.1 1 20.9 / 18.1 1/3 24.1 13.9 3 1 / 3 20.8 / 18.1 1 / 3 12.1 / 10.4 1 18.1 3 6.1 1 / 3 36.1 / 20.8 1 / 3 27.1 / 31.3 1 / 3 31.3 / 27.1 1 27.1 3 9.1 1 / 3 47.8 / 27.4 1 / 3 41.2 / 24.0 1 / 3 36.1 / 20.8 1 36.1 3 12.1 3 41.7 3 36.1 / 31.3 3 18.1 3 47.8 / 41.1 3 24.1 3 69.5 3 60.2 / 52.1 3 30.1 3 83.4 3 72.3 / 62.5 3 36.2 3 111.2 3 96.4 / 83.4 3 47.0 3 139.0 3 120.5/104.3 3 60.3 CONTROL VOLTAGE 208 240 / 208 208 240 / 208 TEMP RISE AIR THROW CFM 26oF 12’ 400 RECOMMENDED MOUNTING HT. Horizontal Vertical 9’ 9’ 277 24 208 240 / 208 208 240 208 277 24 24 WT. (LBS.) 25 25 40oF 12’ 400 9’ 9’ 27 34°F 22’ 700 10’ 12’ 54 45°F 22’ 700 10’ 14’ 55 43°F 32’ 1100 11’ 20’ 64 57°F 32’ 1100 12’ 18’ 65 40/44°F 45’ 2000/1800 12’ 22’ 120 47/53°F 40’ 2000/1800 12’ 20’ 120 40/45°F 55’ 3100/2800 15’ 24’ 120 51/56°F 50’ 3100/2800 15’ 22’ 120 AIR THROW CFM 12’ 400 22’ 700 32’ 1100 International Models UPC# 686334 MODEL 715300 724920 724937 424944 717137 724951 686570 724968 724975 724982 704175 724999 719193 710619 725002 710626 725019 709835 Q3H5103CA1 R3H5103CA1 Q3H5105CA1 R3H5105CA1 Q3H5107CA1 R3H5107CA1 Q3H5110CA1 R3H5110CA1 Q3H5115CA1 R3H5115CA1 Q3H5120CA1 R3H5120CA1 Q3H5125CA1 R3H5125CA1 Q3H5130CA1 R3H5130CA1 Q3H5140CA1 R3H5140CA1 KW BTU/H 3.3 11263 5.0 17065 7.5 25600 10.0 34130 15.0 51195 20.0 68260 25.0 85325 30.0 102390 40.0 136520 VOLTS 380 415 380 415 380 415 380 415 380 415 380 415 380 415 380 415 380 415 PH AMPS 3 5.02 4.6 7.6 6.96 11.4 10.5 15.2 13.9 22.8 20.9 30.4 27.85 38.0 34.8 45.6 41.8 60.85 55.7 CONTROL VOLTAGE TEMP RISE 26 40 34 45 24 43 57 40/44 45’ 47/53 40’ 40/45 55’ 2000/1800 3100/2800 RECOMMENDED MOUNTING HT. Horizontal Vertical 25 9’ 9’ 10’ 12’ 54 10’ 14’ 55 11’ 20’ 64 12’ 18’ 65 12’ 22’ 12’ 20’ 15’ 24’ • For 24V control add “CA1” suffix. • For 120V control add “CA2” suffix. • For other voltages consult factory. NOTES: • 25-50KW models are wired for single or two stage heating and have two speed motors. • Air delivery and motor data on dual voltage units reflect higher voltage. • 600 Volt models available in 5 KW through 30 KW. Contact factory for delivery. • Supply wire on 40 and 50 KW models should have rated insulation of 75oC minimum. • Use T5122 for two stage control. • Use TW123 for two stage control. • Use TFS5102 for two stage control. • Wall thermostat must be used when built-in stratification thermostat is required. WT. (LBS.) 27 120 5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater Recommended Control Options, Control Accessory Options, & Control Accessories MODEL NUMBER F1F5103N HF1B5103N DISCONNECT SWITCH 1Ø 3Ø IN-BUILT WALL MOUNTED DCS 202 NA T5100 ET5SS T5102 T5100 T5102 TW 1512 ET 5SS TW 1512 ET5SS A6176 S2025 ET5SS S2025 TW 1512 ET5SS TW 1512 S2025 F2F5103N NA DCS 403 DCS 202 NA HF2B5103N NA DCS 403 G1G5103N DCS 202 NA P3P5103CA1N NA DCS 403 F1F5105N HF1B5105N DCS 403 NA F2F5105N HF2B5105N G1G5105N P3P5105CA1N F2F5107CA1L HF2B5107CA1L G1G5107CA1L P3P5107CA1L F2F5110CA1L HF2B5110CA1L G1G5110CA1N P3P5110CA1N F3F5115CA1L HF3B5115CA1L P3P5115CA1L HF3B5120CA1L P3P5120CA1N F3F5125CA1L HF3B5125CA1L P3P5125CA1N F3F5130CA1L HF3B5130CA1L P3P5130CA1N F3F5140CA1L HF3B5140CA1L P3P5140CA1N F3F5150CA1L HF3B5150CA1L P3P5150CA1N THERMOSTAT NA DCS 403 NA DCS 202 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 603 NA DCS 603 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 403 NA DCS 403 DCS 603 DCS 403 DCS 403 DCS 603 DCS 403 T5100 T5102 T5100 T5102 T5100 A6176 OR TW123 IN-BUILT WALL MOUNTED THERMOSTAT & SUMMER FAN SWITCH WALL MOUNTED FS5101 FSW5111 NA FS5102 FSW5112 TFS5101 FS5101 FSW5111 NA FS5102 FSW5112 FS5101 FSW5111 FS5102 FSW5112 FS5101 FSW5111 FS5102 FSW5112 SUMMER FAN SWITCH STRATIFICATION THERMOSTAT WALL IN-BUILT MOUNTED TC5103 NA TC5102 TC5103 NA TC5102 TC5103 NA TC5102 TFS5101 TC5103 NA TC1602 NA TC1602 NA TC1602 NA TC1602 NA FS5101 FSW5111 TC1602 FS5102 FS5101 FS5102 FSW5112 FSW5111 FSW5112 NA TC1602 NA DCS 1003 FS5101 FSW5111 TC1602 DCS 403 DCS 1003 DCS 1003 DCS 403 NA DCS 403 DCS 603 FS5102 FSW5112 FS5101 FSW5111 FS5102 FSW5112 FS5101 FSW5111 FS5102 FSW5112 NA NA FS5101 FSW5111 TC1602 DCS 1003 FS5102 FSW5112 NA T5100 A6176 OR TW123 TC5103 TFS5101 NA TC1602 NA TC1602 CONTROL ACCESSORY OPTIONS - FIELD INSTALLED IN HEATER CONTROL ACCESSORIES - REMOTE WALL MOUNTED UPC# UPC# MODEL DESCRIPTION MODEL DESCRIPTION 686334 686334 POWER DISCONNECT SWITCH LINE VOLTAGE THERMOSTAT 717151 DCS202/5100 2 POLE; 20 AMP; 120-277 V.A.C. 691086 **TW1510 SPST; 25 AMP 120-277V 50-90o 717168 DCS403/5100 3 POLE; 40 AMP; 120-600 V.A.C. 691093 *TW1512 DPST; 25 AMP 120-277V 50-90o 717175 DCS603/5100 3 POLE; 60 AMP; 120-600 V.A.C. LOW VOLTAGE THERMOSTAT (ALL CA1 MODELS) 717182 DCS1003/5100 3 POLE; 100 AMP; 120-600 V.A.C. 260008 A6176 SPST; (3.3 - 20 KW UNITS) 50-90O LINE VOLTAGE THERMOSTAT (45 - 90 oF) 691116 TW123 2STAGE; (25 - 50 KW UNITS) 40-90O 692779 T5100 SPST; LINE DUTY 25 AMP 120-277V STRATIFCATION THERMOSTAT 692786 T5102 DPST; LINE DUTY 25 AMP 120-277V 691109 TC1602 LINE VOLT 120-277V 70-140O LOW VOLTAGE THERMOSTAT (ALL CA1 MODELS) (45 - 90 oF) SUMMER FAN SWITCH SPST; LOW VOLT/PILOT DUTY; 125VA ; (3.3-20 KW UNITS) 692779 T5100 692625 FSW5111 SPST; LINE VOLT 120-277V 692793 T5122 2-STAGE; LOW VOLT; 125VA; (25-50 KW UNITS) 692632 FSW5112 SPST; LOW VOLT (W/RELAY) STRATIFICATION THERMOSTAT LOW VOLTAGE T'STAT & SUMMER FAN SWITCH(W/RELAY) (CA1 MODELS) O 692809 TC5102 SPST; LOW VOLT/PILOT DUTY (W/RELAY) ; 70-130 692649 TFS5101 SPST; LOW VOLT 50-90O 692816 TC5103 SPST; LINE DUTY; AMP 120-240V; 70-130O 692502 TFS5102 2 STAGE; LOW VOLT 50-90O SUMMER FAN SWITCH **Any SPST thermostat of sufficient amperage may be substituted. 692823 FS5101 SPST; LINE VOLT ;120-277V *Use DPST thermostat for 3-phase line voltage control in non “C” models. 692830 FS5102 SPST; LINE VOLT ; 480-600V 17 5100 Series 60 KW - 100 KW Suspended Fan Forced Unit Heater Features & Specifications 18 CONSTRUCTION: Heavy gauge steel cabinet with powder coated finish and control compartment housing a master terminal board. The control compartment allows for access through a hinged and latched door, simplifying wiring, installation, and maintenance. HEATING ELEMENT: The heating element is a copper clad steel sheath element with continuously brazed steel fins formed to allow side draw through air flow. OVERHEAT PROTECTION: All units come equipped with manual reset type limit controls to de-energize the heater should an over-temperature situation occur. FAN & MOTOR: Single speed, single phase permanently lubricated, thermally protected motors with ball bearings. The fan override purges the unit of residual heat at shutdown. FIELD INSTALLED OPTIONS: Summer fan switch to operate the fan only, and a heat stratification thermostat for high bay areas. HEATER STAGING: 60 KW and 70 KW are three stage; 80 KW, 90 KW, & 100 KW are four stage. SC5100 FACTORY INSTALLED ELECTRONIC STEP CONTROLLER: The optional factory installed step controller is a first on last off sequencer that will cycle the unit heater stages through an optional wall thermostat. Additionally, the step controller can be controlled by any building management system with 4 to 20 MA or 0 - 10 VDC field supplied control signal. Manufactured in U.S.A. C3 C4 V C2 C1 S C COM Optional Factory Installed Electronic Step Controller 3 OR 4 STAGE POWER STEP CONTROL THERMOSTAT TEST VR2 JUNE 99 001-0102 120 150 RATIO(%) CONTROL 200 VR1 DELAY(s) 12 3 4 5 6 INPUT 30 3 2 1 12 3 4 60 ON ON 90 1 2 REV.1 3 0-10VDC-CONTROL OR C1025 WALL 100 + 4MA-O%HEAT _ 20MA-100%HEAT Dimensions Dimensions (Inches) KW H W D WT (LBS.) 60-70 35 1/2 30 1/2 14 1/2 141 80-100 39 1/2 37 5/8 18 1/2 202 Mounting Brackets and Accessories Wall / Ceiling Bracket Mounting Brackets UPC# 686334 7220002 A5175 60 To 70 7220102 A51100 80 to 100 7220302 B5175 60 to 70 7220402 B51100 80 to 100 7220202 V51100 60 to 100 7220502 DS5175 60 to 70 7220602 DS51100 80 to 100 Model Heater KW 7220902 OFG 5175 60 to 70 7221002 OFG 51100 80 to 100 Description Wall/Ceiling Bracket Heater Bracket Vertical Bracket Dust Shield Fan Guard 5100 Series 60 KW - 100 KW Suspended Fan Forced Unit Heater Electrical Data KW BTU/HR (x 1000) Voltage F3F5160CA1 60 204.7 208 721356 HF3B5160CA1 60/45 204.7/153.6 240/208 721363 P3P5160CA1 60 204.7 721424 F3F5170CA1 70 721431 HF3B5170CA1 721448 19 Amps / Phase Branch Circuit Protection Size 166.7 225 144.6/125 200/175 480 72.3 100 238.9 208 194.4 250 70/52.5 238.9/179.2 240/208 168.7/145.8 225/200 P3P5170CA1 70 238.9 480 84.3 110 721707 HF3B5180CA1 80/60 273/204.7 240/208 192.8/166.7 250/225 721714 P3P5180CA1 80 273 480 96.3 125 721769 HF3B5190CA1 90/67.5 307.1/230.4 240/208 216.9/187.5 300/250 721776 P3P5190CA1 90 307.1 480 108.4 150 721820 HF3B51100CA1 100/75 341.3/256 240/208 241/208.3 350/300 721837 P3P51100CA1 100 341.3 480 120.4 175 UPC# 686334 Catalog Number 721349 Phase Control Voltage 3 24 3 24 3 24 3 24 3 24 Air Delivery Data Temp Rise °F UPC# 686334 Catalog Number 721349 F3F5160CA1 60 721356 HF3B5160CA1 60/45 721363 P3P5160CA1 721424 F3F5170CA1 721431 HF3B5170CA1 CFM at Outlet FPM at Outlet 3400 60 1485 70 HP Motor RPM Max Mounting Air Throw Horizontal Vertical 1/3 1100 50’ 18’ 31’ 3/4 1100 65’ 22’ 40’ 70/53 721448 P3P5170CA1 70 721707 HF3B5180CA1 55/41 721714 P3P5180CA1 55 721769 HF3B5190CA1 721776 P3P5190CA1 721820 HF3B51100CA1 68/51 721837 P3P51100CA1 68 5000 61/46 1529 61 Recommended Control Options UPC# 686334 Summer Fan Switch Catalog Number Step Controller Thermostat Wall Built-In 721349 F3F5160CA1 FS5101 721356 HF3B5160CA1 FS5101 721363 P3P5160CA1 FS5102 721424 F3F5170CA1 FS5101 721431 HF3B5170CA1 FS5101 721448 P3P5170CA1 FS5102 721707 HF3B5180CA1 SC5100 C1025 FSW5112 FS5101 721714 P3P5180CA1 FS5102 721769 HF3B5190CA1 FS5101 721776 P3P5190CA1 FS5102 721820 HF3B51100CA1 FS5101 721837 P3P51100CA1 FS5102 Stratification Thermostat Wall Built-In TFS5101 TC5102 2600 Series Downflow Unit Heater CONSTRUCTION: • 16 gauge steel cabinet with epoxy powder coated finish and control compartment with a hinged and latched access door. • OSHA guards standard with all models. HEATING ELEMENT: • Corrosion resistant element with steel sheath and steel spiral fins. OVERHEAT PROTECTION: • All units come equipped with manual reset limit controls to de-energize the heater should an over-temperature situation occur. FAN and MOTOR: • Totally enclosed, 1 speed, 1 phase permanently lubricated, thermally protected motors with unit bearings on 3KW - 20KW models. Totally enclosed, 2 speed, 1 phase permanently lubricated, thermally protected motors with sleeve bearings on 24KW - 50KW models. • Axial flow fan blade - 1570 RPM max. • All models equipped with fan purge which allows fan to operate after elements are de-energized to purge residual heat. TEMPERATURE CONTROLS: • 208V, 240V, 277V and 480V units have In-Built 24 Volt transformer for low voltage remote thermostat application. • 600V units have In-Built 240V control on 5-20 KW models, 25-50 KW models have 24V control. • 25 KW - 50 KW models may operate as 2 stage heaters if 2 stage remote thermostat is used. DISCONNECT SWITCH: • All models equipped with In-Built disconnect except F3F2640, F3F2650 and H3H2650. INSTALLATION: • Unit can be mounted using optional mounting bracket or field constructed angle iron bracket. • Not recommended for mounting with threaded rod or chain. Standard Heater Radial Louvered Cone Diffuser Manufactured in U.S.A. 2600 Series shown with standard wire guard. Diffusers are field installed. Linear Louvered Diffuser Anemostat Diffuser Dimensions** A B KW 5-20 20 1/2” 15” 25-50 27” 21 1/2” Diffuser Descriptions 20 General Description & Diffuser Information A A A A B B B For general distribution. Choice of other diffusers may be added after installation if required. O.S.H.A guard for fan blade D1604 for 2605-2620, & D1614 for 2625-2650 Do not use with other diffusers. MODEL KW DIM: A DIM: B MODEL DIM: A DIM: B MODEL 5-20 6 1/2" 14 1/4" D1602 5-20 6" 16 1/4" D1603 5-20 D1610 25-50 11 1/2" 24 3/4" D1612 25-50 6" 22 1/4" D1613 25-50 With vanes vertical, straightens air for higher mounting. Closed position for broad horizontal coverage. Adjustable for intermediate requirements. VERTICAL 2605 2607 2610 2615 2620 2625 2630 2640 2650 10 10 22 20 18 32 30 26 24 KW D1600 Affords more precise directional throw where heaters cannot be mounted directly over area to be heated or for heating long narrow areas. W' D' MODEL B KW D' MAX MOUNTING HEIGHT* B B DIM: A DIM: B 7" 19 1/4" 9 3/4" 29 3/4" Blends room air with heated air for widespread distribution without excessive drafts. D' L' 45 DEGREES OPEN D (ft.) MAX MOUNTING HEIGHT D (ft.) MAX MOUNTING HEIGHT D (ft.) MAX MOUNTING HEIGHT W (ft.) L (ft.) MAX MOUNTING HEIGHT D (ft.) 25 25 40 44 48 48 60 64 68 15 15 26 24 22 38 36 32 28 25 25 36 38 40 42 50 50 50 8 8 15 14 13 24 22 20 18 30 30 44 46 50 70 74 78 82 10 10 22 20 18 34 32 30 28 10 10 14 14 15 30 34 36 40 40 40 54 60 66 80 80 90 100 9 9 20 18 16 30 28 26 24 25 25 38 40 42 60 64 67 70 *Minimum mounting height 6 feet. **Dimensions are for all heater models without a diffuser option. Adding a diffuser will change the vertical (”A”) dimension of heater. All mounting distances are in feet. All diagrams show optional mounting bracket. 2600 Series Downflow Unit Heater Product Specifications SPECIFICATIONS: The contractor shall furnish and install the 2600 Series electric vertical discharge unit heaters of the size, capacity and voltage specified. Heaters shall be installed according to the manufacturer’s recommendations and applicable national and local codes. ELEMENTS: Elements shall consist of Nickel Chromium alloy resistance wire embedded and completely surrounded in Magnesium Oxide, enclosed and swagged into corrosion resistant sheaths. Corrosion resistant steel fins shall be permanently attached to the sheaths to provide maximum heat transfer to the air stream. MOTORS: Motors shall be single phase, resilient mounted, totally enclosed, industrial rated with an automatic reset thermal overload protective device. Motors on heaters up to 20 KW capacity shall be permanently lubricated shaded pole type. Over 20 KW, motors shall be permanent split capacitor type. Motors shall be mounted out of the main air stream in such a manner as to allow ambient air to be drawn over the motor to reduce motor temperature. Motor shall be separately removable from beneath the heater without removing the entire heater from mounting bracket. FAN BLADES: Fan blades shall be heavy-duty individually balanced axial flow type. Fan speed shall not exceed 1570 RPM. THERMAL OVERLOAD PROTECTION: All heaters shall be equipped with a manual reset thermal cutout which disconnects elements and motor in the event normal operating temperatures are exceeded. WIRING: Heaters shall be designed for a single supply circuit with elements, motor and control circuits subdivided and fused to conform with the latest National Electric Code and OSHA requirements. All three phase heaters shall have balanced phases. CONTROLS: Heaters shall be controlled by a low voltage wall mounted thermostat. All heaters 25 KW and larger shall be wired for 2 stage operation. 5 KW through 20 KW units are single stage. All heaters shall be equipped with a fan safety device that causes fan to operate after elements are de-energized to purge unit of residual heat. Standard Models UPC# 686334 715751 715768 715775 715782 715799 715805 715812 715829 715836 715843 715850 715867 715874 715881 715898 715904 715911 715928 715935 715942 715959 715966 715973 715980 715997 716000 716017 717502 717519 717526 717533 717540 717557 717564 717571 717588 717595 717601 717618 717625 717632 717649 717656 717663 MODEL F1F2605CA1 H1H2605CA1 G1G2605CA1 F3F2605CA1 H3H2605CA1 P3P2605CA1 U3H2605CA4 F1F2607CA1 H1H2607CA1 G1G2607CA1 F3F2607CA1 H3H2607CA1 P3P2607CA1 U3H2607CA4 F1F2610CA1 H1H2610CA1 G1G2610CA1 F3F2610CA1 H3H2610CA1 P3P2610CA1 U3H2610CA4 F3F2615CA1 H3H2615CA1 P3P2615CA1 U3H2615CA4 H3H2620CA1 P3P2620CA1 U3H2620CA4 F3F2625CA1 H3H2625CA1 P3P2625CA1 U3U2625CA1 F3F2630CA1 H3H2630CA1 P3P2630CA1 U3U2630CA1 F3F2640CA1 H3H2640CA1 P3P2640CA1 U3U2640CA1 F3F2650CA1 H3H2650CA1 P3P2650CA1 U3U2650CA1 KW 5 7.5 10 15 19.4 20 BTU’s 17065 25598 34130 51195 68260 25 85325 30 102390 40 136520 50 170650 VOLTS 208 240 277 208 240 480 600 208 240 277 208 240 480 600 208 240 277 208 240 480 600 208 240 480 600 240 480 600 208 240 480 600 208 240 480 600 208 240 480 600 208 240 480 600 PH 1 3 1 3 1 3 AMPS 24.03 20.83 18.05 13.89 12.04 6.02 4.81 36.05 31.25 27.07 20.84 18.06 9.03 7.22 48.07 41.66 36.1 27.79 24.08 12.04 9.63 41.68 36.12 18.06 14.45 48.16 24.08 19.26 69.48 60.21 30.1 24.08 83.37 72.25 36.12 28.9 111.17 96.33 48.16 38.53 138.96 120.42 60.21 48.16 CONTROL VOLTS 24 TEMP RISE OF CFM WT (LBS.) 34 490 75 45 560 75 26 1200 75 39 1200 75 52 1200 75 24 3300 175 29 3300 175 38 3300 175 48 3300 175 240 24 240 24 240 24 240 24 240 24 21 2600 Series Downflow Unit Heater Field Installed Accessories 22 UPC# 686334 MODEL UPC# MODEL 686334 DESCRIPTION 692632 FSW5112 Summer Fan Switch 691109 TC1602 Wall Mounted Stratification Thermostat Range - 70 oF - 140 oF 717755 A1600 Ceiling Mount Bracket 5-20 KW Models 717762 A1601 Ceiling Mount Bracket 25-50 KW Models DESCRIPTION 717793 D1602 Linear Louvered Diffuser 5-20 KW Models 717809 D1612 Linear Louvered Diffuser 25-50 KW Models 717816 D1600 Radial Louvered Cone Diffuser 5-20 KW Models 717823 D1610 Radial Louvered Cone Diffuser 25-50 KW Models 717830 D1603 Anemostat Diffuser 5-20 KW Models 717847 D1613 Anemostat Diffuser 25-50 KW Models 5700 Series Confined Space Plenum Rated Heater Features • Easily fits between joists for typical installation. • Zero clearance for wall and ceiling mounting as well as floor mounting with appropriate inlet and outlet clearances. • Bracket standard or can be mounted by 3/8” threaded rod (field supplied) • Automatic reset thermal limit for safety • 1 Phase model wattage field changeable from 1874 to 5000 Watts. • 24V control circuit on three phase models with hydraulic thermostat Conforms to ANSI/UL 1995 Certified to CAN/CSA C 22.2 No.236-11 Product Dimensions A E D B F G C A B C D E F G 14.4” 19.4” 14.5” 8.4” 5.1” 9.2” 1.8” Standard Models UPC# 686334 726245 MODEL HF5705T 727252 H3H5705T 726269 P3P5705T 707367 DCS-MT303 WATTS BTU's 5000 17065 4165 14215 3332 11365 2500 VOLTS AMPS TEMP RISE 21 57 oF 17 48 oF 14 38 oF 8533 10 29 oF 3750 12798 18 43 oF 3123 10659 15 36 oF 2500 8553 12 29 oF 240 PHASE 1 208 1 AIR THROW CFM WT. (LBS.) 16' 275 32 16' 275 32 1874 6396 9 21 oF 3750 12799 208 3 10.4 57 oF 16’ 375 32 5000 17065 240 3 12 57 F 16' 275 32 5000 17065 480 3 6 57 oF 16' 275 32 o Optional Field Installed Disconnect Switch, 30 Amp @ 600Volts For 24V control on single phase models delete "T" suffix 5600 Series Multiple Wattage Fan Forced Unit Heater Product Specifications 23 CASING: Fabricated of die formed, heavy gauge steel and finished with two tone, brown and beige, durable powder coated paint. Supply air is drawn through the rear heavy duty expanded steel inlet grill. Heated air is discharged through front adjustable louvers, which are spring loaded for individual adjustment. ELEMENT: Heavy-duty block fin element design. The multiple tap electric connection design allows field conversion to eight wattage settings at 208/240-Volt single phase or 240/480 Volt, 3 phase. Units are available on special order with a specific wattage/voltage setting. MOTOR: Motor shall be totally enclosed, permanently lubricated, all angle industrial rated with thermal overload protection. WIRING: Wiring to terminal block adjacent to incoming knockout in accordance with NEC and local codes. Front view Manufactured in U.S.A. THERMAL OVERLOAD: All heaters shall be equipped with an automatic reset thermal cutout to shut down the element and motor circuits if unsafe operating temperatures are exceeded. CONTROLS: The heater shall have a heavy-duty hydraulic thermostat factory installed and wired. All controls and wiring shall be in a large wiring compartment with hinged door for easy access. An optional disconnect switch shall be available for field installation. MOUNTING: Heaters are standard with a three position-mounting bracket for wall, ceiling or workbench. Heaters can be mounted for horizontal or vertical discharge. Note: Minimum mounting height is 6 feet, and minimum distance from side of heater to nearest wall is 6 inches. Note: Approved for residential applications. Product Dimensions A B C 14” 12-11/16” 14” D E 1-9/16” 1-9/16” F G 9” 2-3/4” Standard Models UPC# 686334 707282 MODEL HF5605T 707299 H3H5605T 707305 P3P5605T 707367 DCS-MT303 WATTS BTU's 5000 4165 3332 11365 2500 VOLTS AIR THROW CFM WT. (LBS.) 16' 275 32 16' 275 57 oF 16’ 375 32 12 57 oF 16' 275 32 6 57 oF 16' 275 32 AMPS TEMP RISE 17065 21 57 oF 14215 17 48 oF 14 38 oF 8533 10 29 oF 3750 12798 18 43 oF 3123 10659 15 36 oF 2500 8553 12 29 oF 1874 6396 9 21 oF 3750 12799 208 3 10.4 5000 17065 240 3 5000 17065 480 3 240 208 PHASE 1 1 Optional Field Installed Disconnect Switch, 30 Amp @ 600Volts For 24V control on single phase models delete "T" suffix 32 “T” Series Multiple Angle Cabinet Unit Heater Product Specifications 24 The electric cabinet unit heater is designed for mounting in any position, fully recessed, semi-recessed or surface mounted. All capacities, voltages, physical sizes, grille arrangements and options shall be as specified on the plans. All units must be field convertible to the following: 1. For control by a field supplied remote thermostat. 2. Load management control with an external dry switch. When closed unit operates under control of either the internal or the external thermostat. When open, unit turns off. 3. Any grille arrangement. CABINET: The cabinet shall be constructed of heavy duty 16 gauge Zinc coated steel. The heater shall have a removable front door for Manufactured in U.S.A. easy access to the control panel, elements, motor-blower assembly, filters and all internal components. The grill configuration must be easily field convertible to any air flow configuration (by removal of no more than four fasteners). The cabinet shall have a textured finish of two coats of powder coat epoxy and be suitable for use with optional kick space base. HEATING ELEMENTS: The heating elements shall be warranted for 1 year and shall be non-glowing design consisting of special high temperature resistance wire enclosed in an incoloy sheath to which steel fins are furnace brazed. The heating elements shall be located directly in front of the blower discharge air for uniform heating. They shall be mounted with a single anchor at one end to minimize effects of thermal expansion and contraction. SAFETY CUTOUT: Thermal safety limits shall be built into the system to automatically shut off heater in event of overheating due to any cause. The safety cutouts shall be of two types: A. The primary limit shall be an automatic capillary type to sense the heat along the full length of the heating elements. It shall de-energize the heaters by opening the coil circuit on the heating contactors. B. The secondary limit shall be a manual reset thermal device to interrupt power to the heating elements. MOTOR AND BLOWER ASSEMBLY: The motors and blowers shall be direct drive and resiliently mounted on rigid heavy gauge frame for quiet operation and long life. The motor shall be two-speed, shaded pole type, rated for the voltage (480 to 600 Volts are single speed only). Each shall have built-in automatic reset overload protection and are life time lubricated. The motor shall be vented and mounted in the air stream to provide maximum cooling of the motor. HIGH AND LOW HEAT RANGES: All units will be supplied as standard with a switch for selecting full heat at high fan speed or reduced heat at low fan speed (On 480 & 600 Volt units the switch changes the heat but not the fan speed). OVER CURRENT PROTECTION: Circuit breakers shall be provided for branch circuit protection where required by NEC. Circuit breakers are optional on all other heaters. TEMPERATURE CONTROL: Integral factory installed thermostat shall be tamper resistant, linear capillary type. Mounting Configurations Up Flow A B Down Flow A A C C D D D A B D D D NOTE: Semi-recessed units are to be recessed at a maximum of 3 1/2” unless grill configuration is front in and front out. MOUNTING CLEARANCES: Proper clearances are indicated for each mountCompletely Semi Semi Completely ing configuration on all positions. MiniRecessed Recessed Recessed Recessed mum clearance from side of unit to the wall is zero inches. Mounting inches are provided in the back of the cabinet, acC B D D D A A cessible through the blower compartZ W X Y Z Y X W X Y X W Z Y ment, if necessary, remove blower deck if additional mounting screws or bolts are Semi Completely Recessed Recessed desired. Blower deck may be slipped forCeiling Mounted ward by loosening four screws at the front KEY: W = 6” minimum, X = 12” minimum, Y = 0” or greater, Z = 24” minimum to provide access to mounting holes. W Y W Y Y Z X Z X X “T” Series Multiple Angle Cabinet Unit Heater Product Features (2-24 KW; All Voltages) • For commercial and institutional application such as stores, schools, offices, transportation terminals, churches, entrance ways. • Wall or ceiling mount; surface, semi-recessed or fully recessed. • (8) air inlet and outlet configurations. • Capacities from 2-24 KW with 230 to 1,000 CFM • Motors are two speed, shaded pole, resilient mounted, direct drive. High/low heat and blower speed offer versatility. • ETL Listed. • Beige powder coated finish • Choice of eight standard control options include unit or wall mounted 120 or 24V thermostats, with or without built-in control transformers. • Industrial type finned tubular elements. • Easily removable fan and element decks for simplified maintenance. • Full length thermal protection. • Limited warranty-one year. Product Dimensions Mounting Hole Locations (Back View of Unit) 1/2”, 3/4” Conduit 1/2”, 3/4” Conduit 1/2”, 1-1/2” Conduit 3/5 KW = 33” 6/10 KW = 46” 1/4” Dia. Mounting Holes 9“ 25” 11-11/16” 25” 12” 24” 44” 56” Knockouts 3“ 4-1/16” 2-3/4” 2-3/8” 1-9/16” 3-3/8” Stocked Models & Features HEATER LENGTH 33” 46” UPC# 686334 MODEL 667142 T33D052033B30D0F 667159 T33D052433B30D0F 667081 T33D054833B30D0F 667197 T46D102433B30D0F 667203 T46D104833B30D0F KW HIGH BTU’s AMPS CFM KW BTU’s 250 3 10239 25.0 / 17.6 5 17065 34130 CFM VOLTS PHASE 15.4 / 9.2 21.8 / 15.4 7.8 10 LOW AMPS 13.5 / 8.2 230 4.6 43.6 / 30.7 500 15.4 6 20478 250 3 10239 500 6 20478 26.9 / 16.2 8.1 460 208 1-3* 240 1-3* 480 3 240 1-3* 480 3 Wt. (lbs.) 99 130 International Models 33” 46” 473620 6333D053834B30D0F1 473637 6333D054134B30D0F1 473644 6346D103834B30D0F1 473651 6346D104134B30D0F1 5 17065 10 34130 7.6 6.97 15.2 13.94 4.56 4.18 9.12 8.36 230 460 380 415 380 3 (4-Wire) 415 *Factory wired for 3-phase, field convertible to 1-phase. • 1 / 3 phase field convertible with 24 Volt control circuit. • Disconnect switch, dust filter, & high low operation. • Built-in thermostat and field convertible for remote thermostat. Accessories UPC# 686334 MODEL SIZE 441568 DC-33 33" 441575 DC-46 46" 441582 DC-66 66" 441599 DC-79 79" DESCRIPTION UPC# 686334 771580 FAM33 33" 771597 FAM46 46" 771603 FAM66 66" 771610 FAM79 79" Kickbase (Pedestal) ONLY RECESSING TRIM FRAMES 453783 TF-33 33" 453790 TF-46 46" 453806 TF-66 66" 453813 TF-79 79" Recessing Trim Frames should be ordered to "trim-out" any recessed or semi-recessed installation. SIZE Fresh Air Make-Up Intake Flange & Kickbase DUCT COLLAR The same model is used for the inlet or outlet. If duct collars are required for both inlet & outlet then 2 must be ordered. MODEL 771542 KB33 33" 771559 KB46 46" 771566 KB66 66" 771573 KB79 79" 99 130 25 “T” Series Multiple Angle Cabinet Unit Heater Custom Specified Models 33” 46” 66” 79” Step 6 Step 7 Step 9 1-PHASE UNITS - AMPS (HIGH) CFM Step 10 F Motor Fusing Option O = Not Required Disposable Filter Option F = Required O = Not Required O M = Required C = Circuit Breaker S = Included Step 8 D Disconnect Option D = Disconnect Switch O = None S Summer Fan Switch O = Not Included B3 Control Options B1, B2, B3, B4, B5, B6, B7, B8 (see control options chart) Phase 3 = Three Phase Step 5 Elements per Heat Deck KW LENGTH Step 4 2 Number of Wires in Electrical Service 2, 3, or 4 Step 3 1 1 = Single Phase Step 2 24 Element Voltage 24 = 240V 27 = 277V 48 = 480V 57 = 600V A = Bottom in / Top out C = Front in / Top out 46 = 46” 33=33” Step 1 08 20 = 208V 41 = 415V D Air Flow Configuration B = Bottom in / Front out D = Front in / Front out 46 Cabinet Size 66 = 66” 79 = 79” T Element KW 2KW through 24KW See model chart for length and KW options. HOW TO DESIGNATE A MODEL: Series Number 26 Step 11 Step 12 3-PHASE UNITS - AMPS (HIGH) 208V 240V 277V 600V 208V 240V 480V 3-WIRE 600V 2 10.6 9.3 8.12 3.83 9.22 8.13 4.14 3.33 2 3 15.4 13.5 11.7 5.5 9.22 8.13 4.14 3.38 4 2 4 20.2 16.7 15.3 7.2 13.4 11.8 6 6.22 5 3 5 25 21.8 19 8 17.6 15.4 7.8 5.5 6 3 6 29.9 26 22.6 10.5 17.6 15.4 7.8 6.3 4 2 2 21.1 18.6 16 7.46 18.7 16.2 8.1 6.5 6 4 3 30.8 26.9 23.1 10.79 18.4 16.2 8.1 6.5 8 4 4 40.4 35.2 30.5 14.12 26.7 23.4 11.7 9.4 10 6 5 50 43.6 37.7 17.5 35.1 30.7 15.4 12.3 12 6 6 59.6 51.9 44.9 20.8 35.1 30.7 15.4 12.3 6 3 2 2 31.8 27.9 24.1 11.3 27.6 24.3 12.3 9.8 9 6 3 3 46.2 40.4 35 16.3 27.6 24.3 12.3 9.9 12 6 4 4 60.6 52.9 45.8 21.3 40.1 35.2 17.7 15.6 15 9 5 5 75 65.4 56.7 25.5 52.6 46.1 23.1 15.7 18 9 6 6 89.4 77.9 67.5 31.3 52.6 46.1 23.1 18.5 8 4 2 2 42.3 37.1 32 14.9 36.7 32.3 16.2 13 12 8 3 3 61.5 53.8 46.5 21.6 36.7 32.3 16.2 13 16 8 4 4 80.7 70.5 61 28.2 53.4 46.8 23.5 18.8 20 12 5 5 NA 87.1 75.4 34.9 70.1 61.4 30.7 24.6 24 12 6 6 NA NA 89.8 41.6 70.1 61.4 30.7 24.6 High Low 2 1 3 Left Right Note: Amps include motor Amp loads. High 250 500 750 1000 Low 230 460 690 920 “T” Series Multiple Angle Cabinet Unit Heater Control Option (Step 8 on Model Designator) 27 SUFFIX DESCRIPTION B3 In-Built 1-Stage Stat and Relays which are operated by an internal 24 Volt source. B4* In-Built 1-Stage Stat and Relays which are operated by an internal 120 Volt source. B5 In-Built 2-Stage Stat & Relays which are operated by an internal 24 Volt source. B6* In-Built 2-Stage Stat and Relays which are operated by an internal 120 Volt source. *Motor fusing included for units with 120V internal or external control source. Disconnect Option “C” Circuit Breaker (Step 10 on Model Designator) KW SINGLE PHASE 208V 240V THREE PHASE 277V 600V 208V 340V 480V 600V 18 20 N/A 24 available required 16 required 15 required required 12 available available 8 10 available 6 available 5 available available 4 available 2 3 required N/A Circuit breakers shown in shaded areas are required by NEC because unit exceeds 48 Amps, all others listed are optional unless otherwise stated. Fan Switch & Motor Fusing (Step 11 on Model Designator) Disconnect Option “D” Disconnect Switch (Step 10 on Model Designator) 20 24 not available Disconnect option is not available on heaters with circuit breaker. 600V available without circuit breaker option "C" 18 480V available without circuit breaker option "C" 16 340V available without circuit breaker option "C" 15 available without circuit breaker option "C" 12 not available 10 not available 8 208V available without circuit breaker option "C" 6 600V available without circuit breaker option "C" 5 THREE PHASE 277V not available 4 available without circuit breaker option "C" 3 240V not available 2 SINGLE PHASE 208V available without circuit breaker option "C" KW SUFFIX DESCRIPTION S Summer Fan Switch M Motor Fusing (when not provided by control option) Filter Option (Step 12 on Model Designator) SUFFIX F W SIZE 33" 46" 66" 79" 33" 46" 66" 79" Qty. REQ'D 1 1 2 2 1 1 2 2 FILTER TYPE Replaceable Washable 8500 Series Commercial Slope Top Wall Convector E = 120V F = 208V • Front In/Top Out or Bottom In/Top Out air pattern. • 16 gauge steel housing powder coated with beige finish. • Tubular pre-wired wireway with 40 Amp capacity. • Connection boxes for right or left hand wiring with combination 1/2” - 3/4” knockouts at back and bottom. Step 1 Step 2 Step 3 Step 4 Step 5 • Stainless steel element with Aluminum fins. • Linear limit type thermal overload with • Pencil proof louver design. • Custom colors available, consult factory. automatic reset. • Limited by max amp draw of 25 Amps (with Note: Not for residential applications. Note: Disconnect limits amperage to 20 Amps. no controls). 1=10”H x 3”D B DST1 Air Flow F=Front in Voltage H=240V G = 277V 2=14“H x 5”D 125 H Watts per Foot Selectable in 1 watt increments up to max per model series 8510= 250 max 8520=500 max 8530=750 max Series Number Manufactured in U.S.A. 5 Unit Length (feet) 2, 3, 4, 5, 6, 7, 8, 9, 0 (enter 0 for 10’) 2 Cabinet Size 3=20”H x 5”D 85 Step 6 Factory Installed Options blank=none T1 or T2=Thermostat R1, R2, or R9=Relay DS=Disconnect (see control option chart) HOW TO DESIGNATE A MODEL: B=Bottom in 28 Step 7 Standard Models HEATER LENGTH 2’ 3’ 4’ 5’ 6’ 7’ 8’ 9’ 10’ WATTS per FOOT 100-250 333-750 100-250 333-750 100-250 333-750 100-250 333-750 100-250 333-750 100-250 333-750 100-250 333-750 100-250 333-750 100-250 333-750 8510 SERIES 8520 SERIES 8530 SERIES 3” Depth x 10” Height Max watts per foot = 250 5” Depth x 14” Height Max watts per foot = 500 5” Depth x 20” Height Max watts per foot = 750 MODEL MODEL MODEL 8512 8522 8532 8513 8523 8533 8514 8524 8534 8515 8525 8535 8516 8526 8536 8517 8527 8537 8518 8528 8538 8519 8529 8539 8510 8520 8530 Note: All models qualify for international use Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges. 8500 Series Commercial Slope Top Wall Convector Product Specifications CABINET: Rugged 16 gauge front cover with discharge louvers in sloped top design. Pencil proof louver design for sloped outlet and front inlet grill. The finish shall be durable powder coated paint. Air flow available as bottom in - top out, or front in - top out. ELEMENT: All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted efficient dielectric to ensure proper heat transfer. Aluminum fins mechanically bonded to steel tube allows for increased surface area and even heat transfer. LIMIT CONTROLS: Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded. WIRING: Connection boxes in either end with ½ inch to ¾ inch knockouts at back and bottom. Tubular prewired wire way with 40 Amp capacity. CONTROLS: Optional built in tamper resistant thermostat and disconnect is adjustable through top outlet louver. MOUNTING: Heater shall be surface mounted to wall or mullion. Bottom inlet units must be mounted a minimum of 4 inches above finished floor front inlet. Voltage & Wattage Specification Voltage Standard Wattages Per Foot Heater Lengths 120-277 100,125,150,165,187,200,250 2’ through 10’ In-Built Control Options SUFFIX DESCRIPTION T1 In-Built Tamper Proof, Single Pole, Bimetal Thermostat - 0°-110°F temp. range, 25 Amp T2 In-Built Tamper Proof, Double Pole, Bimetal Thermostat - 0°-110°F temp. range, 25 Amp DS Double Pole Disconnect Switch, 20 Amp Mounting/Air Flow Options FRONT IN TOP OUT Note: Due to size limitations, 8510 series convectors can only have thermostats as In-Built control options. SUFFIX DESCRIPTION R1 DPST Relay, 30 Amps, up to 277V, 120V coil R2 SPST Relay, 18 Amps @ 277V (max), 24V coil R9 24V Transformer and SPST Relay, 22 Amps @240V, 18 Amps @ 277V (max), 24V coil (cannot be used in conjunction with T2 option) BOTTOM IN TOP OUT 29 8800 Series Institutional Wall Convector 30 Manufactured in U.S.A. • Single phase heaters available in all common voltages from 120V to 600V. • 11 gauge perforated steel housing powder coated with textured ivory finish. • Tamper proof left Oside control panel houses built-in single pole thermostat O - range 40 F-110 F and disconnect switch. Thermostat on 120V-277V units is line voltage and low voltage (24V) on 346V-600V units. • Linear limit type thermal overload with automatic reset. • Tamper proof fasteners • Stainless steel element with Aluminum fins. Note: Not for residential applications. Standard Models UPC# 686334 899000 899062 899123 899185 899246 899307 899369 899017 899079 899130 899192 899253 899314 899376 899024 899086 899147 899208 899260 899321 899383 899031 899093 899154 899215 899277 899338 899390 899048 899109 899161 899222 899284 899345 899406 899055 899116 899178 899239 899291 899352 899413 MODEL E8801050 F8801050 H8801050 G8801050 L8801050 P8801050 U8801050 E8802075 F8802075 H8802075 G8802075 L8802075 P8802075 U8802075 E8803100 F8803100 H8803100 G8803100 L8803100 P8803100 U8803100 E8804125 F8804125 H8804125 G8804125 L8804125 P8804125 U8804125 E8805150 F8805150 H8805150 G8805150 L8805150 P8805150 U8805150 E8806200 F8806200 H8806200 G8806200 L8806200 P8806200 U8806200 WATTS BTU’S 500 1706 750 2560 1000 3413 1250 4266 1500 5120 2000 6826 VOLTS AMPS 120 208 240 277 346 480 600 120 208 240 277 346 480 600 120 208 240 277 346 480 600 120 208 240 277 346 480 600 120 208 240 277 346 480 600 120 208 240 277 346 480 600 4.167 2.404 2.083 1.805 1.445 1.042 0.833 6.25 3.606 3.125 2.708 2.168 1.563 1.25 8.333 4.808 4.167 3.610 2.890 2.083 1.667 10.417 6.010 5.208 4.513 3.613 2.604 2.083 12.5 7.212 6.25 5.415 4.335 3.125 2.5 16.667 9.615 8.333 7.220 5.780 4.167 3.333 VOLTS AMPS 220 240 220 240 220 240 220 240 220 240 220 240 2.3 2.1 3.4 3.1 4.5 4.2 5.7 5.2 6.8 6.3 9.1 8.3 LENGTH (IN.) 18 28 36 48 60 72 International Models UPC# 686334 984140 984157 984164 984171 984188 984195 984201 984218 984225 984232 984249 984250 MODEL M8801050i H8801050i M8802075i H8802075i M8803100i H8803100i M8804125i H8804125i M8805150i H8805150i M8806200i H8806200i WATTS BTU’S 500 1706 750 2560 1000 3413 1250 4266 1500 5120 2000 6826 LENGTH (IN.) 18 28 36 48 60 72 8800 Series Institutional Wall Convector Product Specifications CABINET: Institutional enclosure 11 gauge perforated steel with sloped top design. Heavy duty end caps welded to the enclosure. Control compartment for housing thermostat and disconnect switch is accessible by use of security type fastener. The entire enclosure is protected by epoxy powder coated paint finish. ELEMENT: All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted efficient dielectric to ensure proper heat transfer. Aluminum fins mechanically bonded to steel tube allows for increased surface area and even heat transfer. LIMIT CONTROLS: Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded. WIRING: Wiring connections shall be made in left end of cabinet enclosure. Wiring must enter into control enclosure behind perforated steel grill. CONTROLS: All controls are accessible only through control enclosure door. Security type fasteners restrict access to controls. Built in thermostat and disconnect switch with manual adjustment are located in control enclosure. HOW TO DESIGNATE A MODEL: 3 100 Unit Wattage 050=500 075=750 100=1000 125=1250 150=1500 200=2000 Unit Length 1=18” 2=28” 3=36” 4=48” 5=60” 6=72” Series Number Element Voltage E=120 F=208 G=277 H=240 L=346 P=480 U=600 H 880 left side view 5.00” ACCESS DOOR 18.00” NOTE: Allow 12 inch clearance on left end of unit and 4” to the floor. FLOOR 4.00” Minimum Optional In-Built Controls SUFFIX DESCRIPTION T2 Tamperproof, Hydraulic, Double pole In-Built thermostat range 40°-110°F, 25 Amp 24V* 24 Volt In-Built single pole thermostat for 120V 208V, 240V & 277V models. *Not available on international models 31 4100 Series Recessed Commercial Wall Convector 48 1000 T Total Wattage Control Option Blank=None T or T2=Thermostat R, R2, or R9=Relay (See control option chart) Manufactured in U.S.A. F Voltage/Phase F=208V, 1 Phase G=277V, 1 Phase H=240V, 1 Phase J=208V, 3 Phase K=240V, 3 Phase 25=11”H x 4”D Series Number Cabinet Size 45=20”H x 5”D M41 25 Unit Length (Inches) 24, 36, 48, 60, or 72 HOW TO DESIGNATE A MODEL: 32 • Front In / Front Out air pattern • 16 gauge steel housing powder coated with textured beige finish. • Tubular pre-wired wireway with 40 Amp capacity. • Connection boxes for right or left hand wiring with combination 1/2”-3/4” knockouts at back and bottom. • Steel heating element with steel fins. • Recess trim frame included. • Linear limit thermal overload with automatic • Custom colors available, consult factory. reset. Note: Not for residential applications. M4125 Dimensions - Cabinet Sizes 4” Deep x 11” High LENGTH (Inches) WEIGHT (Lbs.) 24 20 36 33 48 39 60 49 72 56 WATTS per FOOT AVAILABLE VOLTS AVAILABLE PH 187 250 333 208 240 277 1 M4145 Dimensions - Cabinet Sizes 5” Deep x 20” High LENGTH (Inches) WEIGHT (Lbs.) 24 45 36 53 WATTS per FOOT AVAILABLE 187 250 333 VOLTS AVAILABLE 208 240 277 PH WEIGHT (Lbs.) 24 49 36 60 48 71 48 63 60 77 60 87 72 92 72 106 24 47 24 49 36 57 36 60 48 67 48 71 60 82 60 87 72 100 72 106 500 666 208 240 277 1 LENGTH (Inches) 1 WATTS per FOOT AVAILABLE VOLTS AVAILABLE PH 750 208 240 277 1 500 666 750 208 240 3 Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges. 4100 Series Recessed Commercial Wall Convector CABINET: 4100 series casing shall be of square design with front inlet and outlet grills suitable for recess installation. The cabinet is fabricated from 16 gauge cold rolled steel and finished with powder coated baked enamel. Junction boxes are available for left or right wiring and connected by pre-wired 40 Amp capacity wireway. ELEMENT: All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted efficient dielectric to ensure proper heat transfer. Aluminum fins mechanically bonded to steel tube allows for increased surface area and even heat transfer. LIMIT CONTROLS: Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded. WIRING: Wiring connections shall be made in left end of cabinet enclosure. Wiring must enter into control enclosure behind perforated steel grill. CONTROLS: All controls are accessible only through control enclosure door. Security type fasteners restrict access to controls. Built in thermostat with manual adjustment are located in control enclosure. In-Built Control Options for Single Phase Units SUFFIX DESCRIPTION T In-Built Tamper Proof, Single Pole, Hydraulic Thermostat - 40°-110°F temp. range, 25 Amps T2 In-Built Tamper Proof, Double Pole, Hydraulic Thermostat - 40°-110°F temp. range, 25 Amps R DPST Relay, 30 Amps, up to 277V, 120V coil R2 SPST Relay, 18 Amps @ 277V (max), 24V coil R9 24V Transformer and SPST Relay, 22 Amps @24V, 18 Amps @ 277V (max), 24V coil Note: No In-Built control options for 3 phase models. 12” Control Section UNIT LENGTH MODEL 4125 MODEL 4145 12” MSE4120-12 MSE4140-12 Note: Control section required when relay is ordered. Solid Back Panel UNIT LENGTH MODEL 4125 MODEL 4145 24” MS4122 MS4142 36” MS4123 MS4143 48” MS4124 MS4144 60” MS4125 MS4145 72” MS4126 MS4146 33 3000 Series Fan Forced Ceiling Heater Standard Models 34 WHITE SELECTABLE MAX MAX UPC# VOLTS MODEL INSTALLATION WATTAGE BTU'S AMPS 686334 948821 E3035DWBW 750 or 1500 5120 120 13 948838 E3038DWBW 900 or 1800 6143 120 15 948883 H3032DWBW 750 or 1000 - 1500 or 2000 6826 208 / 240 8 948906 G3032DWBW 2000 6826 277 7 Manufactured in U.S.A. Selectable Wattages, Back Cans, And Power Disconnects • Field Installed Accessories Wattage selectable at time of installation - models shipped wired to highest Wattage • Fan purge circuit (has 2 wire control circuit for use with remote wall thermostat) • Models may not be used with remote double pole thermostat • Drywall depth embossments on back can • Powder coated 18 gauge steel front • Manual reset thermal limit • Steel block fin element • Propeller style fan blade - 1060 RPM / 100 CFM • Weight 6 lbs. • Optional field installed control voltage relays available • Rough in dimensions - 9 1/4” Wide - 12 1/8” High - 3 5/8” Deep • Grill dimensions: 9 25/32” Wide - 13” High UPC MODEL DESCRIPTION 686334 996846 30R 24 VOLT RELAY 996853 30R2 120 VOLT RELAY 951500 30R8 208/240 VOLT RELAY 951494 30R7 277 VOLT RELAY 996976 303EX8RW 1" EXTENDER 996969 303EX16RW 2" EXTENDER 996952 303EX32RW 4" SURFACE MOUNT FRAME 460033 TB3000 T-BAR FRAME 3380 Series Commercial Fan Forced Ceiling Heater Product Specifications The heaters are be constructed of a heavy gauge steel housing. The roughin dimensions are 19-3/16” wide x 4” deep. The finish shall be baked-on powder coat in Ceiling White color. The units shall be available in ratings from 1500 through 4800 Watts with an optional factory installed single pole thermostat. The heaters have a low speed 600-RPM motor, which drives a vane axial blower to deliver a quite 175 CFM’s of down flow air. The heating element shall be of the block finned type with large, parallel steel fins for quick heat transfer. Unit shall have as standard, a manual reset capillary type limit control, for added safety. Unit weight 22 pounds. Recess, Surface, Or “T” Bar Mounting Manufactured in U.S.A. Features & Standard Models UPC# MODEL 686334 366489 E3383D-RP 366298 F3386D-RP 366304 F3387D-RP 366342 HF3384D-RP 366359 HF3385D-RP 366366 HF3386D-RP 366373 H3387D-RP 366502 G3383D-RP 366410 G3384D-RP 366427 G3385D-RP 366434 G3386D-RP 366441 G3387D-RP • Fan purge circuit (has 2 wire control circuit for use with remote wall thermostat) • Disconnect switch • White powder coated 18 gauge steel grill • Manual reset thermal limit • Steel block fin element • Vane axial fan blade: 1.5KW - 4.0KW units: 700 RPM motor; 175 CFM 4.8KW units: 900 RPM motor; 200 CFM • Rough in dimensions: 14 3/16” wide x 19 5/16” high x 4” deep • Grill dimensions: 470889 M3384D-RPi 15 3/8” wide x 20 9/64” high • Optional factory installed tamper resistant 470896 M3385D-RPi 470902 M3386D-RPi thermostat KW 1.5 4.0 4.8 2.0 / 1.5 3.0 / 2.3 4.0 / 3.0 4.8 1.5 2.0 3.0 4.0 4.8 1680 2520 4032 BTU’S VOLTS 5120 120 13600 208 16382 208 6826/5120 240/208 10200/7679 240/208 13600/10200 240/208 16382 240 5120 277 6826 277 10200 277 13600 277 16382 277 International Models 5734 8600 13761 220 PH AMPS 1 12.5 19.2 23.1 8.3/7.2 12.5/10.8 16.8/14.4 20 5.4 7.2 10.8 14.4 17.3 TEMP RISE 27 °F 72 °F 76 °F 36 °F 54 °F 72 °F 76 °F 27 °F 36 °F 54 °F 72 °F 76 °F 1 7.6 11.5 18.3 30 °F 50 °F 72 °F Accessories UPC MODEL 686334 377850 BOX3310 381109 3380EX33 460026 TB3380 Thermostat- Add suffix T to model DESCRIPTION Additional Back Can Surface Mounting Adapter 2X2 T-Bar Mounting Kit Factory installed single pole, positive off. Range-60° F-105° F WT. 10 lbs 1 lb 7 lbs RCH Series Commercial Fan Forced Recessed Mounted Ceiling Heater Features • White powder coated 20 gauge grill. • 208V, 240V, & 277V units have manual reset thermal limit. • 480V units have manual reset thermal limit, 24V control transformer, and 24V relay (A1 suffix). • Enclosed steel fin sheath element. • Rough in dimensions: 23-1/16” sq. x 9-1/8” deep. Standard Models Manufactured in U.S.A. Notes Optional controls must be factory installed. Field installation is not acceptable and violates Listing and factory warranty. Wall mounted control panels may control multiple units but cannot be used if in-built controls are selected. 480V units include 24V transformer and relay as standard (A1) only TS option control section can be added. Depth dimension of all 480V models is 10-7/8” Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw designed for 8 to 12 foot ceilings. db RE 10-12 Watt=63.9 Unit Weight: 50 lbs. Recommended Remote Thermostats: Line Voltage: Single Phase 208-240V Single Phase 277V Three Phase ET5DS ET5SS TW1512 Low Voltage: UT1001 Product Specifications Contractor shall supply and install heavy duty ceiling mounted forced air electric heater(s) of the wattage, voltage and phase as indicated on the plans. The heater shall be so designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by means of an electric motor and axial flow fan blade. Heaters shall be recessed type and mounted flush with the finished ceiling. The return grille assembly shall be constructed of a one piece heavy gauge steel with 1/4” slots for return air and concentric rings for uniform air discharge. Grille assembly shall be attached to chassis by tamper-resistant (allen head) machine screws. All parts of enclosure shall be heavy gauge steel, zinc coated both sides and finished in neutral off white powder coat paint. Enclosure shall be constructed of 1/6” x 3/8” rounded edge horizontal steel louvers which shall be spaced for maximum opening of 5/16”. Louvers shall be welded at every intersection to evenly spaced 1/8” diameter vertical members. Discharge grille to have concentric rings for uniform air discharge. Grille assembly shall be attached to chassis by tamper-resistant (allen head) machine screws. All part of enclosure shall be heavy gauge steel, Zinc coated both sides and finished in neutral off white colored powder coat finish. Motor shall be permanent lubricated, unit bearing, totally enclosed, impedance protection. Motors shall operate at no more than 1300 RPM and shall be same voltage as the heater. Heaters shall have a rating of 425 CFM at 710 F.P.M. with a maximum temperature rise of 44°F and 63.9 DB RE 1012 Watt. Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins. Each sheathed element shall consist of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by magnesium oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2” cold conductor pins extending into sheath and shall have a density of no more than 60 Watts per inch. Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded. For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted. Heaters shall be ETL listed. UPC# 686344 367653 367677 367660 318471 470186 470209 470247 367684 367707 367691 318488 470193 470216 470254 367714 367738 367721 318501 367745 367752 318587 367769 367783 367776 318549 367790 367806 318402 366106 81RCH2 21RCH2 71RCH2 41RCH2A1 83RCH2 23RCH2 43RCH2A1 81RCH3 21RCH3 71RCH3 41RCH3A1 83RCH3 23RCH3 43RCHA1 81RCH4 21RCH4 71RCH4 41RCH4A1 83RCH4 23RCH4 43RCH4A1 81RCH5 21RCH5 71RCH5 41RCH5A1 83RCH5 23RCH5 43RCH5A1 PT3480 470971 470988 470995 471008 471015 471022 M3482T2i N3482T2i M3483T2i N3483T2i M3484T2i N3484T2i MODEL KW 2 2 3 3 4 4 5 5 2 3 4 BTU’S VOLTS PH AMPS 208 9.6 240 8.3 1 277 7.2 480 4.2 208 5.6 6826 240 3 4.8 480 2.4 208 14.4 240 12.5 1 277 10.8 10200 480 6.3 208 8.3 240 3 7.2 480 3.6 208 19.2 240 16.8 1 277 14.4 13600 480 8.3 208 11.1 240 3 9.7 480 4.8 208 24.1 240 20.8 1 277 18.1 17000 480 10.4 208 13.9 240 3 12.1 480 6.1 Recess Frame - Weight 5 lbs. International Models 220 9.1 6826 240 8.3 220 13.6 10200 1 240 12.5 220 18.2 13600 240 16.7 6826 TEMP RISE 15 °F 15 °F 22 °F 30 °F 37 °F 15 °F 22 °F 30 °F Factory Installed Control Sections SUFFIX DESCRIPTION A1 Transformer with 24V Secondary and 24V Relay S Disconnect Switch TA1S Thermostat / Transformer / Disconnect Switch TA1 Single Pole Thermostat and Transformer with 24V Secondary and 24V Relay A1S T2 T2S R R1 R2 T L Transformer with 24V Secondary and 24V Relay and Disconnect Switch Double Pole Thermostat Double Pole Thermostat and Disconnect Switch Relay Control Voltage Same as Heater (control voltage field supplied) Relay 24V Control Voltage (control voltage field supplied) Relay 120V Control Voltage (control voltage field supplied) Single Pole (480V only) Factory installed adjustable louver diffuser option. Product Dimensions 35 SCH Series Commercial Fan Forced Surface Mounted Ceiling Heater 36 Product Specifications Contractor shall supply and install heavy duty ceiling mounted forced air electric heater(s) of the wattage, voltage and phase as indicated on the plans. The heater shall so be designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by mean of an electric motor and axial flow fan blade. Motor: Motor shall be permanent lubricated, unit bearing, totally enclosed shaded pole type with impedance protection. Motors shall operate at no more than 1300 RPM and shall be same voltage as the heater. Performance: Heaters shall have a rating of 425 CFM at 710 F.P.M. with a maximum temperature rise of 44°F and 63.9 DB RE 1012 Watt. Element: Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins. Each sheathed element shall consist of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by Magnesium Oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2” cold conductor pins extending into sheath and shall have a density of no more than 60 watts per inch. Thermal Overload: Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded. For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted. Approval: Heaters shall be ETL listed. Commercial and Institutional Applications: Use in - vestibules, entrance ways, lobbies, rest rooms and small office and guard building applications. Manufactured in U.S.A. Product Dimensions Standard Models UPC# 686334 367516 367530 367523 324335 470155 470162 470223 367547 367561 367554 324342 323864 470179 470230 367578 367592 367585 324359 367608 367837 324366 367615 367639 367622 324373 367646 367844 324380 81SCH2 21SCH2 71SCH2 41SCH2 83SCH2 23SCH2 43SCHA1 81SCH3 21SCH3 71SCH3 41SCH3 83SCH3 23SCH3 43SCHA1 81SCH4 21SCH4 71SCH4 41SCH4 83SCH4 23SCH4 43SCH4 81SCH5 21SCH5 71SCH5 41SCH5 83SCH5 23SCH5 43SCH5 470919 470926 470933 470940 470957 470964 M3472T2i N3472T2i M3473T2i N3473T2i M3474T2i N3474T2i MODEL KW 2 2 3 3 4 5 2 3 4 BTU’S VOLTS 208 240 277 480 208 6826 240 480 208 240 10200 277 480 208 10200 240 480 208 240 277 480 13600 208 240 480 208 240 277 480 17000 208 240 480 International Models 220 6826 240 220 10200 240 220 13600 240 6826 PH 1 3 1 3 1 3 1 3 1 AMPS 9.6 8.3 7.2 4.2 5.6 4.8 2.4 14.4 12.5 10.8 6.3 8.3 7.2 3.6 19.2 16.8 14.4 8.3 11.1 9.7 4.8 24.1 20.8 18.1 10.4 13.9 12.1 6.1 9.1 8.3 13.6 12.5 18.2 16.7 TEMP RISE 15 °F 22 °F 30 °F TS TA1S A1S T UNITS UPC# 686334 MODEL VOLTS CONTACTORS 605700 AF3401-24 208 605793 AH3401-24 240 605854 AG3401-24 277 605748 AF3402-24 208 605786 AH3402-24 240 605847 AG3402-24 277 605731 AF3403-24 208 605779 AH3403-24 240 605830 AG3403-24 277 BOX SIZE 1 @ 35 AMPS 12" x 12" x 4 1/2" 2 @ 35 AMPS 15" x 15" x 4 1/2" 3 @ 35 AMPS 18" x 18" x 4 1/2" Notes 37 °F Optional controls must be factory installed. Field installation is not acceptable and violates Listing and factory warranty. 15 °F 22 °F 30 °F Factory Installed Control Sections SUFFIX Wall Mounted Control Panels DESCRIPTION Single Pole Thermostat - range 40°-110°F and Disconnect 1-Phase Switch Single Pole Thermostat - range 40°-110°F & Transformer with 3-Phase 24V Secondary and 24V Relay & Disconnect Switch 1 or 3 Transformer with 24V Secondary and 24V Relay and Phase Disconnect Switch Single Pole (480V only) Factory installed control sections add 2-5/16” to the height of the unit. Wall mounted control panels may control multiple units but cannot be used if In-Built controls are selected. 480V units include 24V transformer and relay as standard (A1) - only TS option control section can be added. Depth dimension of all 480V models is 10-7/8” Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw designed for 8 to 12 foot ceilings. db RE 10-12 Watt=63.9 Unit weight: 32 lbs. Recommended Remote Thermostats: Line Voltage: Single Phase 208-240V Single Phase 277V Three Phase ET5DS ET5SS TW1512 Low Voltage: UT1001 CP & RCP Series Radiant Ceiling Panel Heaters Product Description 37 For Surface Or Recessed Installation, Radiant Ceiling Panels radiate energy like the solar radiation which warms us, heats objects, not the air. With no moving parts, these heating panels create gentle warmth and toasty comfort. Manufactured in U.S.A. Radiant Ceiling Panels provide a low surface temperature and broad heat distribution. Clean, gentle comfortable heat that is ideal for offsetting perimeter heat loss or neutralizing downdrafts over glass. These versatile and flexible panels may be used virtually anywhere in homes, schools, hospitals, motels and a broad variety of other commercial or industrial installations. Product Specifications Construction: Radiant Ceiling Panels shall be made of highest quality steel casing. Front panel shall be painted with textured powder coated finish. Electric Resistance element is fixed between dielectric material and insulation. Two inches of insulation is compressed to one inch by back panel to minimize upward heat loss and radiant efficiency. Radiant panels shall have 36” pre-wired flexible cable for easy installation and wiring connections. Installation: CP Series shall be designated as 2x2 or 2x4 size. All panels are 1” thick. The size shall be nominal dimension to be manufactured to fit drop ceiling systems. Standard units will fit regular “T” Bar frame. For regular or trim line or other frame sizes, special construction is required. RCP Series shall be used in recess mounting applications. RCP Series shall be 2” less in width to recess between nominal 24” center ceiling joists. RCP Series shall be complete with recess frame for finished construction. Accessories: Surface mounting frames shall be optional for surface mounting the CP Series, and are Aluminum mill finish. Frames can be painted white to match panel. Options: Silk-screening the exposed surface to match ceiling tiles is available, as well as silicone sealed metal parts for high humidity applications. CP Series - “T” Bar & Surface Mounted UPC# MODEL WATTS BTU's AMPS VOLTS 686334 Dimensions: 2' x 4' (Nominal) x 1" 458719 CP805 2 208 458726 CP125 500 1707 4.2/2.1 120/240 458733 CP705 2 277 458740 CP807 4 208 458757 CP127 750 2560 6.3/3.1 120/240 458764 CP707 3 277 Dimensions: 2' x 2' (Nominal) x 1" 458771 CP802 1 208 458788 CP122 250 853 2.1/1.0 120/240 458795 CP702 .9 277 458801 CP803 2 208 458818 CP123 375 1280 3.1/1.6 120/240 458825 CP703 1 277 459105 SF400 Surface Frame for 2’ x 4’ Panels (CP only) 459099 SF200 Surface Frame for 2’ x 2’ Panels RCP Series - Frame in Ceiling Mounted WT 20 lb. 20 lb. 13 lb. 13 lb. 10 lb. 6 lb. UPC# MODEL WATTS BTU's AMPS VOLTS 686334 Dimensions: 2' x 4' (Including Recessing Frame) 458832 RCP805 2 208 458849 RCP125 500 1707 4.2/2.1 120/240 458856 RCP705 2 277 458863 RCP807 4 208 458870 RCP127 750 2560 6.3/3.1 120/240 458887 RCP707 3 277 Dimensions: 2' x 2' (Including Recessing Frame) 458894 RCP802 1 208 458900 RCP122 250 853 2.1/1.0 120/240 458917 RCP702 .9 277 458924 RCP803 2 208 458931 RCP123 375 1280 3.1/1.6 120/240 458948 RCP703 1 277 WT 30 lb. 30 lb. 19 lb. 19 lb. International Models UPC# MODEL WATTS BTU's AMPS VOLTS 686334 Dimensions: 2' x 4' (Nominal) x 1" 471039 CP2205i 420 1434 1.9 220 471046 CP125i 500 1707 4.2/4.1 120/240 471053 CP2207i 630 2150 2.9 220 471060 CP127i 750 2560 6.3/3.1 120/240 Dimensions: 2' x 2' (Nominal) x 1" 471077 CP2202i 210 717 0.95 2.1/1.0 120/240 471084 CP122i 250 853 0.9 277 471091 CP2203i 315 1075 1.4 220 3.1/1.6 120/240 471107 CP123i 375 1280 1.4 277 WT 20 20 13 13 UPC# MODEL WATTS BTU's AMPS VOLTS WT 686334 Dimensions: 2' x 4' (Including Recessing Frame) 471114 RCP2205i 420 1434 1.9 220 471121 RCP125i 500 1707 4.2/4.1 120/240 30 471138 RCP2207i 630 2150 2.9 220 471145 RCP127i 750 2560 6.3/3.1 120/240 Dimensions: 2' x 2' (Including Recessing Frame) 471152 RCP2202i 210 717 0.95 220 471169 RCP122i 250 853 2.1/1.0 120/240 19 471176 RCP2203i 315 1075 1.4 220 471183 RCP123i 375 1280 3.1/1.6 120/240 CVX Series Radiant Cove Ceiling Heater 38 Manufactured in U.S.A. Product Description Cove Heaters have a subtly contoured concave surface with a saw-tooth profile. The concave parabolic face plate performs a two-fold function: (1) it focuses the infrared rays and (2) directs the heat downward along cold perimeters and toward the center of the room. The sawtooth surface design increases the radiating surface area by 45%, thereby increasing the comfort level of the room faster and insuring more rapid recovery from heat losses. Product Specifications Furnish and install Electric Cove Heaters where specified. The heaters shall be constructed of .962” thick Aluminum. The heater surface shall be concave in contour and saw-tooth in profile. The finish shall be of powder coat white finish. The heaters shall be available in ratings from 450 through 1250 Watts, at 120, 240, 208 and 277 Volts. The heating element shall be of Nichrome wire, embedded in Magnesium Oxide powder, enclosed and sealed in Aluminum metal tubing. The heater shall be listed by ETL and the elements shall be supplied with a one year limited warranty. Standard Models UPC# 686334 457583 457590 457606 457613 457620 457637 457644 457651 457668 457675 457682 457699 457705 457712 457729 457736 457743 457750 457767 457774 457781 457798 457804 457811 457828 457835 457842 457859 CV4512X CV45X CV45YX CV4527X CV6012X CV60X CV60YX CV6027X CV7512X CV75X CV75YX CV7527X CV9012X CV90X CV90YX CV9027X CV10012X CV100X CV100YX CV10027X CV11012X CV110X CV110YX CV11027X CV12512X CV125X CV125YX CV12527X 471190 471206 471213 471220 471237 471244 471251 471268 471275 471282 471299 471305 471312 471329 CV4522Xi CV45Xi CV6022Xi CV60Xi CV7522Xi CV75Xi CV9022Xi CV90Xi CV10022Xi CV100Xi CV11022Xi CV110Xi CV12522Xi CV125Xi MODEL WATTS BTU's AMPS 450 4 450 2 1536 450 2.0 450 2 600 5.0 600 3 2048 600 3 600 2 750 6 750 3 2560 750 3.6 750 3 900 8 900 4 3072 900 4 900 3 1000 8 1000 4 3413 1000 5 1000 4 1100 9 1100 5 3754 1100 5 1100 4.0 1250 10 1250 5 4266 1250 6.0 1250 5 International Models 2.0 450 1536 1.9 2.7 600 2048 2.5 3.4 750 2560 3.1 4.1 900 3072 3.8 4.5 1000 3413 4.2 5.0 1100 3754 4.6 5.7 1250 4266 5.2 Accessories & Dimensions VOLTS 120 240 208 277 120 240 208 277 120 240 208 277 120 240 208 277 120 240 208 277 120 240 208 277 120 240 208 277 220 240 220 240 220 240 220 240 220 240 220 240 220 240 LENGTH WT. 42” 7 lb. 60” 10 lb. 72” 13 lb. 84” 14 lb. 96” 17 lb. 108” 19 lb. 120” 21 lb. 42” 7 60” 10 72” 13 84” 14 96” 17 108” 19 120” 21 UPC# 686334 MODEL DESCRIPTION WT. 457927 CVCBX Ceiling Bracket* 1/2 lb. 457866 CVB42X 42” Blank Section 6 lb. 457873 CVB60X 60” Blank Section 8 lb. 457880 CVB84X 84” Blank Section 12 lb. 457912 CVSP Aerosol Touch-up Paint 1 lb. * Order 2 for units up to 72” Order 3 for units over 72” 3000 Series Midsized Commercial Fan Forced Wall Heater - Multiple Wattage Features Approved for wall or ceiling installation Manufactured in U.S.A. • Wattage selectable at time of installation. • Models shipped wired to highest wattage. • Approved for horizontal mounting - right or left discharge. • Fan purge circuit. • Disconnect switch. • Drywall depth embossments on back can. • 18 gauge powder coated steel & extruded Aluminum front. • Manual reset thermal limit. • Steel block fin element. • Propeller style fan blade: 1060 RPM motor; 100 CFM. • Weight 6 lbs. • Rough in dimensions: 9 1/4” Wide x 12 1/8” High x 3 5/8” Deep. • Grill dimensions: 10” Wide x 13 1/8” High. Standard Models UPC# 686334 MODEL SELECTABLE INSTALLATION WATTAGE MAX VOLTS BTU’s MAX AMPS TAMPERPROOF IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90º TEMPERATURE RANGE) 996211 E3055T2DWB 750 or 1500 5120 120 12.5 996228 E3058T2DWB 900 or 1800 6143 120 15.0 996259 F3052T2DWB 1000 or 2000 6826 208 8.3 945691 F30522T2DWB 7680 208 10.8 996280 H3052T2DWB 6826 208 / 240 8.3 945721 H30522T2DWB 7680 240 9.4 996310 G3052T2DWB 6826 277 7.2 500 or 750 or 1000 or 1250 or 1500 or 1750 or 2250 750 or 1000 - 1500 or 2000 500 or 750 or 1000 or 1250 or 1500 or 1750 or 2250 2000 TAMPERPROOF IN-BUILT SINGLE POLE THERMOSTAT (50º - 90º TEMPERATURE RANGE) 996068 E3055TDWB 750 or 1500 5120 120 12.5 996075 E3058TDWB 900 or 1800 6143 120 15.0 996105 F3052TDWB 1000 or 2000 6826 208 8.3 945639 F30522TDWB 7680 208 10.8 996136 H3052TDWB 6826 208 / 240 8.3 945660 H30522TDWB 7680 240 9.4 996167 G3052TDWB 6826 277 7.2 500 or 750 or 1000 or 1250 or 1500 or 1750 or 2250 750 or 1000 - 1500 or 2000 500 or 750 or 1000 or 1250 or 1500 or 1750 or 2250 2000 Accessories UPC# 686334 MODEL DESCRIPTION 996945 305EX8 1” EXTENDER 996938 305EX16 2” EXTENDER 996921 305EX32 4” SURFACE MOUNT FRAME 39 AFA Series Commercial Fan Forced Wall Heater Features 40 • Disconnect switch. • Built-In tamper proof thermostat. • Automatic fan delay circuit. • Powder coated 18 gauge steel grill with extruded Aluminum front frame. • Automatic reset thermal limit. • Steel block fin element. • Vane axial fan blade: 600 RPM motor; 175 CFM • Rough-in dimensions: 14-3/16” Wide x 19-7/16” High x 4” Deep • Grill dimensions: 15-29/32” Wide x 20-27/32” High Product Specifications Furnish and install Heavy-Duty Forced Air wall heaters, where specified. The heaters shall be constructed of a heavy 18 gauge steel housing with an extruded Aluminum frame. The rough-in dimensions are 19-7/16” High x 14-3/16” Wide x 4” Deep. The units shall be available in ratings from 750 to 4800 Watts at 240, 208, and 277 Volts. The heaters shall have a low-speed 600 RPM, 4-pole motor which drives a vane axial Manufactured in U.S.A. blower to deliver a quiet 175 CFM of down flow air. The heating element shall be of the sealed tubular type with large, parallel steel fins Standard Models for quick heat transfer. Unit shall have as a standard, WT. UPC# a thermal overload cut-off for added safety, fan delay MODEL WATTS BTU’s VOLTS AMPS 686334 LBS. switch and built-in tamper proof thermostat which shall IN-BUILT SINGLE POLE TAMPERPROOF THERMOSTAT (50º - 90º TEMPERATURE RANGE) be calibrated to provide a range of 55°F. to 85°F. and FOR DOUBLE POLE THERMOSTAT REPLACE “T” IN MODEL NUMBER WITH “T2” manual disconnect switch. 382052 AFA107D 750 2560 6.25 Optional accessories shall include a surface and semi381994 AFA110D 1000 3413 120 8.3 recess mounting adapter. All heaters shall be listed by 380881 AFA115D 1500 5120 12.5 26 ETL. The heating element shall be supplied with a 380935 AFA840D 4000 13800 19.2 208 381024 AFA848D 4800 16560 23 manufactures 1-year limited warranty. 380942 380959 380966 380973 381031 380980 380997 381000 381017 381048 398077 398084 398091 398107 AFA215D AFA220D AFA230D AFA240D AFA248D AFA715D AFA720D AFA730D AFA740D AFA748D AFA840D-3 AFA240D-3 AFA848D-3 AFA248D-3 1500 / 1125 5120 / 3840 2000 / 1500 6284 / 5120 240 / 208 3000 / 2250 10350 / 7763 4000 / 3000 13800 / 10350 4800 16560 240 1500 5120 2000 6284 3000 10350 277 4000 13800 4800 16560 4000 13800 208 4800 16560 4000 13800 240 4800 16560 International Models 396424 M3324TD-RPi 3360/1680 11468/5734 220 396437 M3325TD-RPi 4032/2016 13761/6881 6.2 / 5.4 8.3 / 7.2 12.5 /10.8 16.7/14.4 20 4.1 7.2 10.8 14.4 17.3 11.11 13.33 9.64 11.57 15.3/7.64 18.3/9.16 27 29 26 27 29 Accessories UPC# 686334 MODEL 328746 BOX AFA DESCRIPTION Additional Rough-in Box 328753 AFAEX33 4” Surface Mounting Frame 30 27 328760 AFAEX16 ----- Suffix - HD WT. lbs. TYPE 3 Field Installed 2” semi recess extender 16 Gauge Steel Heavy Duty Grill 1 1 Factory Installed 2 4400 Series Low Profile Commercial Fan Forced Wall Heater - With Wall Box Manufactured in U.S.A. • Powder coated 20 gauge steel front with extruded Aluminum frame. • Manual reset thermal limit. • Finned tubular steel element. • Propeller style fan blade - 2200 RPM/70 CFM • Weight 9 lbs. • Rough in dimensions: 14 1/2” Wide x 7 1/8” High x 3 1/2” Deep • Grill dimensions:16 7/8” Wide x 8” High • Unit not approved for ceiling mount applications. • Unit can be positioned to allow left, right or top discharge. Standard Models UPC MAX MODEL VOLTS WATTS AMPS 686334 BTU’S DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50º - 90º F) 328326 F4420T2RP 208 2000 6826 9.6 328333 HF4475T2RP 750 / 562 2560 / 1920 3.1 / 2.7 328340 HF4410T2RP 1000 / 750 3413 / 2560 4.2 / 3.6 240/208 328357 HF4415T2RP 1500 / 1125 5120 / 3840 6.3 / 5.4 328364 HF4420T2RP 2000 / 1500 6826 / 5120 8.3 / 7.2 SINGLE POLE IN-BUILT THERMOSTAT (RANGE 50º - 90º F) 328371 E4475TRP 750 2560 6.25 328388 E4410TRP 120 1000 3413 8.33 328395 E4415TRP 1500 5120 12.5 328401 F4420TRP 208 2000 6826 9.6 Accessories UPC 686334 329910 329903 329897 328449 MODEL DESCRIPTION 4400EX8 4400EX16 4400EX32 4300PB 1” SEMI RECESSING EXTENDER 2” SEMI RECESSING EXTENDER 4” SURFACE MOUNTING FRAME WALL PLATE ADAPTOR (OD 21.5”x12.25”) WT. LBS. 2 3 4 1 AFC & AFH Series Heavy-Duty Fan Forced Wall Heaters Features • Powder coated bar stock steel tamper proof grille, with extruded Aluminum frame and 16 gauge housing. • In-Built double pole tamper proof thermostat with a 40°-110°F temperature range & positive off; 3 phase heaters have 3 pole thermostat for positive off position. • Manual reset thermal limit switch. • Corrosion resistant steel tubular element with brazed steel fins. • Permanently lubricated, unit bearing, shaded pole motor with impedance protection. • Propeller type fan blade: Note: Wall box required - may be 1400 RPM motor; 245 CFM ordered early for rough in purposes. • Factory installed options: Manufactured in U.S.A. - contactors (3420 & 3450 series) - circuit breakers (3450 series) - control transformers (3450 series) Standard Models HEATER UPC 686334 691130 691192 691178 384629 384643 691239 691314 691277 384636 384650 691338 691383 691369 691406 691413 691437 691512 691482 691536 691567 MODEL AFC8120T AFC2120T AFC7120T AFC8380 AFC2320 AFC8130T AFC2130T AFC7130T AFC8330 AFC2330 AFC8140T AFC2140T AFC7140T AFC8340T AFC2340T AFC8150T AFC2150T AFC7150T AFC8350T AFC2350T HEATER UPC 686334 691611 691680 312295 384667 384681 687683 691772 312288 384674 384698 691789 691819 311991 691857 316651 312981 312134 312387 691901 313070 MODEL AFH8120T AFH2120T AFH7120T AFH8320 AFH2320 AFH8130T AFH2130T AFH7130T AFH8330 AFH2330 AFH8140T AFH2140T AFH7140T AFH8340T AFH2340T AFH8150T AFH2150T AFH7150T AFH8350T AFH2350T WALL BOX UPC 686334 MODEL WATTS BTU’s VOLTS PH SERIES 3420 - ROUGH-IN DIMENSIONS: 19-3/8” H x 14-1/4” W x 4-1/4” D GRILL DIMENSIONS: 21-15/32” H x 17-7/16” W 691574 Box 3420 2000 6826 2000 6826 3000 10239 3000 10239 4000 13652 5000 WALL BOX UPC 686334 MODEL WATTS 17065 BTU’s 208 240 277 208 240 208 240 277 208 240 208 240 277 208 240 208 240 277 208 240 1 3 1 3 1 3 1 3 VOLTS PH SERIES 3450 - ROUGH-IN DIMENSIONS: 23-1/16” H x 14-1/4” W x 4-1/4” D GRILL DIMENSIONS: 25-1/32” H x 17-7/16” W 691918 Box 3450 2000 6826 2000 6826 3000 10239 3000 10239 4000 5000 13652 17065 208 240 277 208 240 208 240 277 208 240 208 240 277 208 240 208 240 277 208 240 1 3 1 3 1 3 1 3 AMPS WT. 9.6 8.3 7.2 5.6 4.8 14.4 12.5 10.8 8.3 7.3 19.2 16.7 14.4 11.1 9.6 24 20.8 18.1 13.9 12.0 41 lbs. AMPS WT. 9.6 8.3 7.2 5.6 4.8 14.4 12.5 10.8 8.3 7.3 19.2 16.7 14.4 11.1 9.6 10.4 20.8 18.1 13.9 12.0 55 lbs. 41 AFC & AFH Series Heavy-Duty Fan Forced Wall Heaters 42 Product Specifications Contractor shall supply and install heavy duty wall mounted forced air electric heaters of the wattage, voltage and phase as specified. The heater shall so be designed to provide an even distribution of heated air to the space to be heated by drawing return air in the peripheral area of the heater across and through the element which shall then be discharged from the center section of the heater by means of an electric motor and axial flow fan blade. Heaters shall be recessed type to extend no more than 1-1/2” from the finished wall or surface mounted to extend no more than 5-3/4” from the finished wall or semi-recessed type to extend no more than 3-1/2” from finished wall or semi-recessed type to extend no more than 2-1/2” from finished wall. ENCLOSURE: Heater front shall withstand 10.8 ft. lbs. (324 poundals) impact and 400 lbs. static force applied to an 8 sq. in. area at center grille location with less than 1/16” permanent distortion. The combination return and supply grille assembly shall be constructed of 1/16” x 3/8” rounded edge horizontal steel louvers which shall be spaced for maximum opening of 1/4”. Louvers shall be welded at every intersection to three evenly spaced 1/16” diameter vertical members and completely framed in a heavy gauge natural anodized Aluminum extrusion. Front assembly shall be attached to the chassis by hidden tamper-resistant (Allen-head) machine screws. All other parts shall be 16 gauge steel Zinc coated, both sides finished in a high gloss or bronze colored baked powder coat finish. MOTOR: Motor shall be a permanently lubricated unit bearing, totally enclosed shaded pole type with impedance protection. Motors shall operate at no more than 1400 RPM and shall be same voltage as the heater. A protective shield shall surround the motor to separate return air from heated air. PERFORMANCE: Heaters shall have a rating of 245 CFM at 660 F.P.M. with a maximum temperature rise of 73°F. ELEMENTS: Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins. Each sheathed element shall consist of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by Magnesium Oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2” cold conductor pins extending into the sheath and shall have a density of no more than 60 Watts per inch. THERMAL OVERLOAD: Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded. For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted. APPROVAL: Heaters shall be ETL Listed. OPTIONAL CONTROL SYSTEMS: Heaters shall be operated from wall-mounted, line voltage, heavy-duty (tamper-proof) thermostats. Heaters with built-in, pre-wired contactors shall be operated from wall-mounted, line voltage, pilot duty (tamper-proof) thermostats. Heaters built with, pre-wired contactors (and control transformers) shall be operated from wall-mounted, pilot duty (24V) or (120V) wall-mounted tamper-proof thermostats. Heaters shall be controlled by integrally mounted thermostats. Thermostats shall be heavy-duty, hydraulic type with a range of 40°F to 80°F and with remote sensing bulb placed in the return air. Thermostats shall be electrically rated at least 125% of heater rating. Thermostats AFC & AFH Series Heavy-Duty Fan Forced Wall Heaters Product Specifications shall be heavy-duty, hydraulic type with a range of 40°F to 80°F and with remote sensing bulb placed in the return air. Thermostats shall be electrically rated at least 125% of heater rating. Thermostats shall also act as a disconnect by breaking all ungrounded conductors in the OFF position. (Thermostat control knob shall be covered by a 16 gauge tamper-proof access plate to prevent adjustment by unauthorized personnel.) CONTACTORS: Where required, heaters shall be equipped with heavy-duty, definite purpose contactors with flame path separators and dust covers. Contactors shall cycle all ungrounded conductors. Contactors shall have holding coils (of the same voltage as the heater) or (120 Volts) or (24 Volts). CONTROL TRANSFORMERS: Heater shall be equipped with a Class 2 control transformer, sealed rating of 20 VA, to supply control circuits of (24 Volts) or (120 Volts). (120 Volt secondaries not available in single phase heaters over 3 KW). CIRCUIT BREAKERS (3450 Series Only): Heaters shall be equipped with built-in circuit breakers in order to allow the heaters to be supplied from feeder taps. A separate switch providing a positive off for control circuits shall be included where required. Circuit breakers and control switches shall be arranged so that all line side conductors will be separately enclosed when heater front is removed for servicing so that no current carrying parts are accessible without the use of additional tools. Field Installed Accessories Units with transformers must have a contactor. A control transformer with 120V secondary is available on all 3-phase models, 208V/240V 1-phase units up to 3KW, and up to 4 KW on 277V. All heaters must be installed with a wall box. MODEL DESCRIPTION Suffix - R SERIES OPTIONS AFC AFH Contactor with Coil same as heater YES YES Suffix - R1 Contactor with 24V Coil YES YES Suffix - R2 Contactor with 120V Coil YES YES Suffix - C Circuit Breakers - all models NO YES Suffix - A1* Control Transformers With 24V Secondary NO YES Suffix - A2* Control Transformers With 120V Secondary NO YES UPC# 686334 MODEL DESCRIPTION WT. 329095 AFCEX34 4” Surface Mounting Sleeve 6 lb. 329101 AFCEX16 2” Semi-Recessing Sleeve 4 lb. 329118 AFCEX8 1” Semi-Recessing Sleeve 4 lb. 329125 AFHEX34 4” Surface Mounting Sleeve 5 lb. 329132 AFHEX16 2” Semi-Recessing Sleeve 4 lb. 329149 AFHEX8 1” Semi-Recessing Sleeve 3 lb. 43 3310 Series Fan Forced Wall Heater - Without Summer Fan Switch Features • Powder coated 18 gauge steel front. • Automatic reset thermal limit. Manufactured in U.S.A. • Vane axial fan blade: 600 RPM / 175 CFM. • Rough in dimensions: 14-3/16” Wide x 19-15/16” High x 4” Deep. • Grill dimensions: 15-3/8” Wide x 20-9/64” High. • Steel block fin element. • Weight 22 lbs. • Units with dual wattage, factory wired to highest wattage. • Wattage selectable at time of installation on some models. 44 Standard Models UPC 686334 326346 326353 326360 326377 326407 326414 326421 326438 326445 326452 326469 382526 380652 379946 380300 380560 379984 380317 329873 328494 328500 379179 326629 MODELS WITH IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90º F TEMPERATURE RANGE) WHITE MAX WATTS VOLTS IVORY UPC WHITE BTU’s MODEL 686334 MODEL E3312T2RP 326483 E3312T2RPW 1000 3413 1500 5120 120 E3313T2RP 326490 E3313T2RPW 750 2560 F3316T2RP 326506 F3316T2RPW 4000 13648 208 F3317T2RP 326513 F3317T2RPW 4800 16380 3000 / 2250 10240 HF3315T2RP 326544 HF3315T2RPW 1500 / 1125 5120 240 / 208 4000 / 3000 13648 HF3316T2RP 326551 HF3316T2RPW 2000 / 1500 6826 H3317T2RP 326568 H3317T2RPW 4800 16380 240 G3314T2RP 326575 G3314T2RPW 2000 6826 G3315T2RP 326582 G3315T2RPW 3000 10240 277 G3316T2RP 326599 G3316T2RPW 4000 13648 G3317T2RP 326605 G3317T2RPW 4800 16380 8.3 12.5 6.25 19.2 23 12.5 / 10.8 6.2 / 5.4 16.8 / 14.4 8.3 / 7.2 20.0 7.2 10.8 14.4 17.3 MODELS WITH IN-BUILT SINGLE POLE THERMOSTAT (50º - 90º F TEMPERATURE RANGE) E3312TRP 382618 E3312TRPW 1000 3413 1500 5120 120 E3313TRP 384162 E3313TRPW 750 2560 F3316TRP 384186 F3316TRPW 4000 13648 208 F3317TRP 384193 F3317TRPW 4800 16380 3000 / 2250 10240 HF3315TRP 382229 HF3315TRPW 1500 / 1125 5120 240 / 208 4000 / 3000 13648 HF3316TRP 382236 HF3316TRPW 2000 / 1500 6826 H3317TRP 382243 H3317TRPW 4800 16380 240 G3314TRP 384261 G3314TRPW 2000 6826 G3315TRP 328517 G3315TRPW 3000 10240 277 G3316TRP 328524 G3316TRPW 4000 13648 G3317TRP 384292 G3317TRPW 4800 16380 8.3 12.5 6.25 19.2 23 12.5 / 10.8 6.2 / 5.4 16.8 / 14.4 8.3 / 7.2 20.0 7.2 10.8 14.4 17.3 MODELS WITHOUT AN IN-BUILT THERMOSTAT 326766 E3312RPW 1000 3413 1500 5120 326773 E3313RPW 750 2560 326780 F3316RPW 4000 13648 326797 F3317RPW 4800 16380 3000 / 2250 10240 326827 HF3315RPW 1500 / 1125 5120 4000 / 3000 13648 326834 HF3316RPW 2000 / 1500 6826 326841 H3317RPW 4800 16380 326858 G3314RPW 2000 6826 326865 G3315RPW 3000 10240 326872 G3316RPW 4000 13648 326889 G3317RPW 4800 16380 8.3 12.5 6.25 19.2 23 12.5 / 10.8 6.2 / 5.4 16.8 / 14.4 8.3 / 7.2 20.0 7.2 10.8 14.4 17.3 IVORY E3312RP 326636 E3313RP 328531 326650 F3316RP F3317RP 326681 HF3315RP 326698 HF3316RP 326704 326711 326728 326735 326742 H3317RP G3314RP G3315RP G3316RP G3317RP 120 208 240 / 208 240 277 AMPS 3310 Series Fan Forced Wall Heater - With Summer Fan Switch Features • Powder coated 18 gauge steel front. • Automatic reset thermal limit. Manufactured in U.S.A. • Steel block fin element. • Weight 22 lbs. • Vane axial fan blade: 600 RPM / 175 CFM. • Grill dimensions: 15-3/8” Wide x 20-9/64” High. • Rough in dimensions: 14-3/16” Wide x 19-15/16” High x 4” Deep. • Units with dual wattage, factory wired to highest wattage. • Wattage selectable at time of installation on some models. Product Specifications Typical Specifications: Furnish and install Electric Forced Air Heaters where specified. The heaters shall be constructed of a heavy gauge steel housing. The rough-in dimensions are 14-3/16” Wide x 19-5/16” High x 4” Deep. The finish shall be powder coated paint in ivory or white color. The units shall be available in ratings from 750 through 4800 Watts. The heaters shall have a low speed 600 RPM motor which drives a vane axial blower to deliver a quiet 175 CFM of down flow air. The heating element shall be of the sealed block fin type with large, parallel steel fins for quick heat transfer. Unit shall have a standard thermal overload cutoff for added safety, a fan switch for fan only operation, and is available with a single pole, or double pole built-in thermostat, or no thermostat. The in-built thermostat shall be calibrated to provide a range of 50 degrees F. to 90 degrees F. All heaters shall be listed by ETL. The heating element shall be supplied with a manufacturer’s 1 year limited warranty. Standard Models UPC 686334 326063 326070 326087 326094 326124 326131 326148 382571 379618 377713 377782 377607 377690 377768 ------- MODELS WITH IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90ºF TEMPERATURE RANGE) WHITE WATTS MAX BTU’s VOLTS UPC IVORY WHITE 686334 E3312T2SRP 326209 E3312T2SRPW 1000 3413 1500 5120 120 E3313T2SRP 326216 E3313T2SRPW 750 2560 F3316T2SRP 326223 F3316T2SRPW 4000 13648 208 F3317T2SRP 326230 F3317T2SRPW 4800 16380 3000 / 2250 10240 HF3315T2SRP 326261 HF3315T2SRPW 1500 / 1125 5120 240 / 208 4000 / 3000 13648 HF3316T2SRP 326278 HF3316T2SRPW 2000 / 1500 6826 H3317T2SRP 326285 H3317T2SRPW 4800 16380 240 IVORY MODELS WITH IN-BUILT SINGLE POLE THERMOSTAT (50º - 90ºF TEMPERATURE RANGE) E3312TSRP 382595 E3312TSRPW 1000 3413 1500 5120 120 E3313TSRP 384018 E3313TSRPW 750 2560 F3316TSRP 384025 F3316TSRPW 4000 13648 208 F3317TSRP 384032 F3317TSRPW 4800 16380 3000 / 2250 10240 HF3315TSRP 384070 HF3315TSRPW 1500 / 1125 5120 240 / 208 4000 / 3000 13648 HF3316TSRP 384087 HF3316TSRPW 2000 / 1500 6826 H3317TSRP 384094 H3317TSRPW 4800 16380 240 International Models 3360 11468 ---396480 M3315T2SRPWi 1680 5734 220 4032 13761 ---396493 M3316T2SRPWi 2016 6881 AMPS 8.3 12.5 6.25 19.2 23 12.5 / 10.8 6.2 / 5.4 16.8 / 14.4 8.3 / 7.2 20.0 8.3 12.5 6.25 19.2 23 12.5 / 10.8 6.2 / 5.4 16.8 / 14.4 8.3 / 7.2 20.0 15.27 7.64 18.33 9.16 Note: Fan switch not available on 277V models. 277V models are available without a fan switch on previous page. Accessories - All Models UPC 686334 377850 329958 IVORY MODEL UPC 686334 BOX3310 377850 3310EX33R 329965 SUFFIX D WHITE MODEL BOX3310 3310EX33WR DESCRIPTION ADDITIONAL BACK CAN SURFACE MOUNTING FRAME DISCONNECT SWITCH ACCESSORY TYPE Field Installed Factory Installed 45 3200 Series Midsized Fan Forced Wall Heater - With Wall Box 46 • • • • • • • • • • • Features Units have white powder coat finish. Approved for horizontal mounting - right or left discharge. Drywall depth embossments on back can. Powder coated 18 gauge steel front. Manual reset thermal limit. Finned tubular steel element. Manufactured in U.S.A. Weight 6 lbs. Propeller style fan blade: 2200 RPM / 70 CFM. Optional field installed In-Built thermostat. Rough in dimensions: 9-1/4” Wide, 12-1/8” High, 3-5/8” Deep. Grill dimensions: 9-25/32” Wide, 13” High. “TWO WIRE INSTALLATION” Standard Models UPC MODEL 686334 VOLTS WATTS MAX AMPS BTU’S BUILT-IN DOUBLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE 383462 F3220T2RPW 208 2000 6826 383479 H3275T2RPW 240 750 2560 3.1 383486 HF3210T2RPW 1000 / 750 3413 / 2560 4.2 / 3.6 383493 HF3215T2RPW 383509 HF3220T2RPW 383516 HF3222T2RPW 240/208 9.6 1500 / 1125 5120 / 3840 6.3 / 5.4 2000 / 1500 6826 / 5120 8.3 / 7.2 2250 / 1688 7680 / 5762 9.4 / 8.1 International Models - BUILT-IN DOUBLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE 396387 M3210T2RPWi 840 2867 3.8 396394 M3215T2RPWi 1260 4300 5.7 396400 M3220T2RPWi 396417 M3222T2RPWi 220 1680 5734 7.6 1890 6451 8.6 Standard Models - BUILT-IN SINGLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE 383523 E3275TRPW 383530 E3210TRPW 383547 E3215TRPW 383554 E3275RPW 383561 E3210RPW 383578 E3215RPW 120 750 2560 6.25 1000 3413 8.33 1500 5120 12.5 NO BUILT-IN THERMOSTAT 120 750 2560 6.25 1000 3413 8.33 1500 5120 12.5 9.6 383585 F3220RPW 208 2000 6826 383592 H3275RPW 240 750 2560 3.1 383608 HF3210RPW 1000 / 750 3413 / 2560 4.2 / 3.6 383615 HF3215RPW 383622 HF3220RPW 383639 HF3222RPW 240/208 1500 / 1125 5120 / 3840 6.3 / 5.4 2000 / 1500 6826 / 5120 8.3 / 7.2 2250 / 1688 7680 / 5762 9.4 / 8.1 Accessories FIELD INSTALLED COMPONENTS UPC 686334 MODEL DESCRIPTION 383646 32T1 Single Pole thermostat with positive off for 120V units 50o - 90o F 383653 32T2 Double Pole thermostat with positive off for 240/208V units 50o - 90o F SURFACE MOUNTED EXTENDERS & FRAMES WHITE DESCRIPTION UPC 686334 MODEL 996976 303EX8RW 1” EXTENDER 996969 303EX16RW 2” EXTENDER 996952 303EX32RW 4” SURFACE MOUNT FRAME 4300 Series Low Profile Fan Forced Wall Heater - With Wall Box Features Available in ivory or white. Powder coated 20 gauge steel front. Manual reset thermal limit. Finned tubular steel element. Manufactured in U.S.A. Weight 9 lbs. Propeller style fan blade - 2200 RPM / 70 CFM Rough in dimensions: 14-1/2” Wide, 7-1/8” High, 3-1/2” Deep Grill dimensions: 16-3/4” Wide, 7-5/8” High Unit not approved for ceiling mount applications. Unit can be positioned to allow left, right or top discharge. • • • • • • • • • • Standard Models IVORY UPC 686334 327695 327701 327718 327725 327732 ------------327794 327800 327817 327824 327831 327848 327855 327862 327954 327961 327978 327985 327992 328005 328012 328029 WHITE MODEL UPC 686334 MODEL VOLTS WATTS MAX BTU’s DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50° - 90°F) F4320T2RP 327749 F4320T2RPW 208 2000 6826 HF4375T2RP 327756 HF4375T2RPW 750 / 562 2560 / 1920 HF4310T2RP 327763 HF4310T2RPW 1000 / 750 3413 / 2560 240/208 HF4315T2RP 327770 HF4315T2RPW 1500 / 1125 5120 / 3840 HF4320T2RP 327787 HF4320T2RPW 2000 / 1500 6826 / 5120 International Models - DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50° - 90°F) ---396448 M4375T2RPi 630 2150 ---396455 M4310T2RPi 840 2869 220 ---396462 M4315T2RPi 1260 4300 ---396479 M4320T2RPi 1680 5733 Standard Models - SINGLE POLE INBUILT THERMOSTAT (RANGE 50° - 90°F) E4375TRP 327879 E4375TRPW 750 2560 E4310TRP 327886 E4310TRPW 120 1000 3413 E4315TRP 327893 E4315TRPW 1500 5120 F4320TRP 327909 F4320TRPW 208 2000 6826 HF4375TRP 327916 HF4375TRPW 750 / 562 2560 / 1920 HF4310TRP 327923 HF4310TRPW 1000 / 750 3413 / 2560 240/208 HF4315TRP 327930 HF4315TRPW 1500 / 1125 5120 / 3840 HF4320TRP 327947 HF4320TRPW 2000 / 1500 6826 / 5120 NO IN-BUILT THERMOSTAT E4375RP 328036 E4375RPW 750 2560 E4310RP 328043 E4310RPW 120 1000 3413 E4315RP 328050 E4315RPW 1500 5120 F4320RP 328067 F4320RPW 208 2000 6826 HF4375RP 328074 HF4375RPW 750 / 562 2560 / 1920 HF4310RP 328081 HF4310RPW 1000 / 750 3413 / 2560 240/208 HF4315RP 328098 HF4315RPW 1500 / 1125 5120 / 3840 HF4320RP 328104 HF4320RPW 2000 / 1500 6826 / 5120 AMPS 9.6 3.1 / 2.7 4.2 / 3.6 6.3 / 5.4 8.3 / 7.2 2.9 3.8 5.7 7.6 6.25 8.33 12.5 9.6 3.1 / 2.7 4.2 / 3.6 6.3 / 5.4 8.3 / 7.2 6.25 8.33 12.5 9.6 3.1 / 2.7 4.2 / 3.6 6.3 / 5.4 8.3 / 7.2 Accessories UPC 686334 WHITE MODEL ACCESSORY OPTIONS WT. LBS. 328456 4300EX8W 1” SEMI RECESSING EXTENDER 2 328463 4300EX16W 2” SEMI RECESSING EXTENDER 3 4300EX32 328470 4300EX32W 4” SURFACE MOUNTING FRAME 4 4300P 328487 4300PW WALL PLATE ADAPTOR (OD 21.5” x 12.25”) 1 329774 43T SINGLE POLE THERMOSTAT 50O - 90O F 1 329781 43T2 DOUBLE POLE THERMOSTAT 50O - 90O F 1 IVORY MODEL UPC 686334 327657 4300EX8 327664 4300EX16 327671 327688 FIELD INSTALLED THERMOSTATS 47 4800 Series Register Style Fan Forced Wall Heater - With Wall Box 48 Manufactured in U.S.A. UPC MODEL 686334 Features • Units have white powder coat finish. • Powder coated 20 gauge steel front. • Manual reset thermal limit. • Finned tubular steel element. • Propeller style fan blade - 2200 RPM / 70 CFM. • Weight 9 lbs. • Rough in dimensions: 14-1/2” Wide x 7-1/8” High x 3-1/2” Deep. • Grill dimensions: 16-3/4” Wide x 7-5/8” High. • Unit not approved for ceiling mount applications. • Left discharge only. Standard Models VOLTS MAX WATTS BTU’S AMPS DOUBLE POLE IN-BUILT THERMOSTAT (40º - 110º F TEMPERATURE RANGE) 328159 F4820T2RPW 328166 HF4875T2RPW 328173 HF4810T2RPW 328180 HF4815T2RPW 328197 HF4820T2RPW 208 240/208 2000 6826 9.6 750 / 562 2560 / 1920 3.1 / 2.7 1000 / 750 3413 / 2560 4.2 / 3.6 1500 / 1125 5120 / 3840 6.3 / 5.4 2000 / 1500 6826 / 5120 8.3 / 7.2 SINGLE POLE IN-BUILT THERMOSTAT (50º - 90º F TEMPERATURE RANGE) 328203 E4875TRPW 328210 E4810TRPW 328227 E4815TRPW 328234 F4820TRPW 750 2560 6.25 1000 3413 8.33 1500 5120 12.5 2000 6826 9.6 750 2560 6.25 1000 3413 8.33 1500 5120 12.5 2000 6826 9.6 750 / 562 2560 / 1920 3.1 / 2.7 1000 / 750 3413 / 2560 4.2 / 3.6 1500 / 1125 5120 / 3840 6.3 / 5.4 2000 / 1500 6826 / 5120 8.3 / 7.2 120 208 NO IN-BUILT THERMOSTAT 328241 E4875RPW 328258 E4810RPW 328265 E4815RPW 328272 F4820RPW 328289 HF4875RPW 328296 HF4810RPW 328302 HF4815RPW 328319 HF4820RPW 120 208 240/208 Accessories UPC# 686334 MODEL DESCRIPTION WT. LBS. 328456 4300EX8W 1” SEMI RECESSING EXTENDER 2 328463 4300EX16W 2” SEMI RECESSING EXTENDER 3 328470 4300EX32W 4” SURFACE MOUNTING FRAME 4 328487 4300PW WALL PLATE ADAPTOR (OD 21.5” x 12.25”) 1 329774 43T SINGLE POLE THERMOSTAT 50O - 90O F 1 329798 48T2 DOUBLE POLE THERMOSTAT 50O - 90O F 1 3900 Series Hydronic Electric Baseboard Heater • Permanent mount self contained unit. • Heating elements are immersed in a heat transferring liquid enclosed by a Copper tube casing with Aluminum fins. • Powder coated 12 gauge heavy duty extruded Aluminum housing with junction boxes located on each end of the unit. • Automatic linear limit. • Wire guard extends along the entire outlet area of the baseboard. • Commercial Brown unit has in-built wireway. • Special colors available, consult factory. • Suitable for high altitude applications. • 1 Year element warranty. Manufactured in U.S.A. Standard Models STANDARD WHITE UPC MODEL 686334 111416 E3904-28 111423 F3904-28 111430 H3904-28 111447 G3904-28 111454 E3906-36 111461 F3906-36 111478 H3906-36 111485 G3906-36 111492 E3910-48 111508 F3910-48 111515 H3910-48 111522 G3910-48 111539 E3912-60 111546 F3912-60 111553 H3912-60 111560 G3912-60 111577 E3915-72 111584 F3915-72 111591 H3915-72 111607 G3915-72 111614 F3920-96 111621 H3920-96 111638 G3920-96 COMMERCIAL BROWN UPC MODEL 686334 111645 E3904-28C 111652 F3904-28C 111669 H3904-28C 111676 G3904-28C 111683 E3906-36C 111690 F3906-36C 111706 H3906-36C 111713 G3906-36C 111720 E3910-48C 111737 F3910-48C 111744 H3910-48C 111751 G3910-48C 111768 E3912-60C 111775 F3912-60C 111782 H3912-60C 111799 G3912-60C 111805 E3915-72C 111812 F3915-72C 111829 H3915-72C 111836 G3915-72C 111842 F3920-96C 111850 H3920-96C 111867 G3920-96C WATTS BTU’S. VOLTS AMPS 400 400 400/300 400/300 600 600 600/450 600/450 1000 1000 1000/750 1000/750 1250 1250 1250/938 1250/938 1500 1500 1500/1125 1500/1125 2000 2000/1500 2000/1500 1360 1360 1360/1024 1360 2048 2048 2048/1536 2048 3413 3413 3413/2560 3413 4265 4265 4265/3201 4265 5100 5100 5100/3825 5100 6826 6826/5100 6826 120 208 240/208 277/240 120 208 240/208 277/240 120 208 240/208 277/240 120 208 240/208 277/240 120 208 240/208 277/240 208 240/208 277/240 3.3 1.92 1.6/1.4 1.4 5 2.9 2.5/2.2 2.2 8.3 4.8 4.2/3.6 3.6 10.4 6 5.2/4.5 3.6 12.5 7.2 6.3/5.4 5.4 9.6 8.3/7.2 7.2 HEATER LENGTH (IN.) WT. (LBS) 28 16 36 22 48 27 60 33 72 41 96 58 Product Specifications & Dimensions The entire heater casing shall be TEMPERATURE LIMITING DEVICE constructed of 6063 extruded Aluminum. 3.00” minimum thickness of .100” (12 gauge) Aluminum shall be acceptable. Outlet grill shall cover entire length of air discharge opening and be constructed of steel. All casing and grill construction shall be painted with high quality durable powder coated paint. The heating element shall be high quality 8.50” Nichrome wire encased in Magnesium Oxide and sealed in copper tube. The heating element shall 1.43 be sealed in .312” diameter Copper tube and be immersed in heat transfer liquid. Aluminum fins 4.10 shall be mechanically bonded to the entire heated length of the element for even heat transfer. 2.42 Linear automatic thermal limit shall WIRE NUT extend the entire heater length of element and protect heater in case of an over-temperature 1.60 2.1 condition. Optional controls shall be mounted in junction box enclosures at either end of heater. Optional integral thermostat shall be located in junction box with adjustment knob or for tamper-proof operation. Optional disconnect switch shall be mounted in junction box. Optional 120 Volt or air conditioning receptacle shall be mounted in junction box. Optional installation accessories shall include inside and outside corner sections for complete wall perimeter fit. Profile of corners and grill shall have appearance of heat sections for continuous architectural design. Corner accessories and heater sections shall be secured by alignment pins for easy alignment of multiple heater applications. 49 3700 Series Architectural Style Electric Baseboard Heater 50 • Available in white or brown with stainless steel heating element and aluminum fins. • Powder coated 12 gauge heavy duty extruded Aluminum housing construction with junction boxes located on each end of the unit. • An automatic thermal linear limit is used along the entire heated length of the unit. • Wire guard extends along the entire outlet area of the baseboard. • Special colors available, consult factory. Manufactured in U.S.A. Product Specifications Standard Models STANDARD WHITE UPC 686334 MODEL COMMERCIAL BROWN UPC 686334 MODEL WATTS BTU’s VOLTS AMPS 116008 E3703-024 116435 E3703-024B 375 1275 120 3.1 116015 F3703-024 116442 F3703-024B 375 1275 208 1.8 116022 H3703-024 116459 H3703-024B 375 / 281 1275 / 955 240 / 208 1.6/1.4 1.6/1.2 116039 G3703-024 116466 G3703-024B 375 / 281 1275 / 955 277 / 240 116046 E3705-028 116473 E3705-028B 500 1706 120 4.2 116053 F3705-028 116480 F3705-028B 500 1706 208 2.4 116060 H3705-028 116497 H3705-028B 500 / 375 1706 / 1275 240 / 208 2.1/1.8 1706 / 1275 277 / 240 1.8/1.6 116077 G3705-028 116503 G3705-028B 500 / 375 116084 E3706-036 116510 E3706-036B 600 2040 120 5 116091 F3706-036 116527 F3706-036B 600 2040 208 2.9 116107 H3706-036 116534 H3706-036B 600 / 450 2040 / 1530 240 / 208 2.5/2.2 2040 / 1530 277 / 240 2.2/1.9 116114 G3706-036 116541 G3706-036B 600 / 450 116121 E3707-040 116558 E3707-040B 750 2550 120 6.3 116138 F3707-040 116565 F3707-040B 750 2550 208 3.6 116145 H3707-040 116572 H3707-040B 750 / 563 2550 / 1914 240 / 208 3.1/2.7 2550 / 1914 277 / 240 2.7.2.6 116152 G3707-040 116589 G3707-040B 750 / 563 116169 E3710-048 116596 E3710-048B 1000 3413 120 8.3 116176 F3710-048 116602 F3710-048B 1000 3413 208 4.8 116183 H3710-048 116619 H3710-048B 1000 / 750 3413 / 2550 240 / 208 4.2/3.6 3.6/3.1 116190 G3710-048 116626 G3710-048B 1000 / 750 3413 / 2550 277 / 240 116206 G3707-048 116633 G3707-048B 750 2550 277 3.4 116213 E3712-060 116640 E3712-060B 1250 4250 120 10.4 116220 F3712-060 116657 F3712-060B 1250 4250 208 6 116237 H3712-060 116664 H3712-060B 1250 / 938 4250 / 3189 240 / 208 5.2/4.5 116244 G3712-060 116671 G3712-060B 1250 / 938 4250 / 3189 277 / 240 4.5/3.9 116251 G3709-060 116688 G3709-060B 938 3189 277 3.4 116268 E3715-072 116695 E3715-072B 1500 5100 120 12.5 116275 F3715-072 116701 F3715-072B 1500 5100 208 7.2 116282 H3715-072 116718 H3715-072B 1500 / 1125 5100 / 3825 240 / 208 6.3/4.7 116299 G3715-072 116725 G3715-072B 1500 / 1125 5100 / 3825 277 / 240 5.4/4.7 116305 G3711-072 116732 G3711-072B 1125 3825 277 4.1 116312 F3717-084 116749 F3717-084B 1750 5950 208 8.4 116329 H3717-084 116756 H3717-084B 1750 / 1313 5950 / 4464 240 / 208 7.3/6.3 116336 G3717-084 116763 G3717-084B 1750 / 1313 5950 / 4464 277 / 240 6.3/5.5 116343 G3713-084 116770 G3713-084B 1313 4464 277 4.7 116350 F3720-096 116787 F3720-096B 2000 6826 208 9.6 116367 H3720-096 116794 H3720-096B 2000 / 1500 6826 / 5100 240 / 208 8.3/7.2 116374 G3720-096 116800 G3720-096B 2000 / 1500 6826 / 5100 277 / 240 7.2/6.3 116381 G3715-096 116817 G3715-096B 1500 5100 277 116398 F3725-120 116824 F3725-120B 2500 8532 208 116404 H3725-120 116831 H3725-120B 2500 / 1875 8532 / 6375 240 / 208 10.4/9.0 116411 G3725-120 116848 G3725-120B 2500 / 1875 8532 / 6375 277 / 240 9.0/7.8 116428 G3718-120 116855 G3718-120B 1875 Note: Refer to 3900 Series for product dimension specifications. 6375 277 HEATER LENGTH (IN.) WT. (LBS.) 24 14 28 16 36 22 40 27 48 31 60 33 72 41 84 49 96 58 120 67 5.4 12 6.8 The entire heater casing shall be constructed of 6063 extruded Aluminum. Minimum thickness of .100” (12 gauge) Aluminum shall be acceptable. Outlet grill shall cover entire length of air discharge opening and be constructed of steel. All casing and grill construction shall be painted with high quality durable powder coated paint. The heating element shall be high quality nichrome wire encased in Magnesium Oxide and sealed in a stainless steel tube. Linear automatic thermal limit shall extend the entire heater length of element and protect heater in case of an over-temperature condition. Optional controls shall be mounted in junction box enclosures at either end of heater. Optional integral thermostat shall be located in junction box with adjustment knob or for tamper-proof operation. Optional disconnect switch shall be mounted in junction box. Optional 120 Volt or air conditioning receptacle shall be mounted in junction box. Optional installation accessories shall include inside and outside corner sections for complete wall perimeter fit. Profile of corners and grill shall have appearance of heat sections for continuous architectural design. Corner accessories and heater sections shall be secured by alignment pins for easy alignment of multiple heater applications. Hydronic & Architectural Electric Baseboard Heater Accessories Field Installed Accessories Standard White DESCRIPTION Commercial Brown UPC# 686334 MODEL UPC# 686334 MODEL Single Pole, In-Built T-Stat, 22A @ 120-240V; 18A @ 277V; 50°-90° F 111874 3900T1 111959 3900T1C Double Pole, In-Built T-Stat, 22A @ 120-240V; 18A @ 277V; 50°-90° F 111881 3900T2 111966 3900T2C Air Conditioning Receptacle Section, 20 Amp @ 125-277V 111898 3900AC 111997 3900ACC 120V. Receptacle Section, 15 Amp 111904 3900REC 112000 3900RECC Disconnect Switch, 20 Amp @ 125-277VAC; DPST 111942 3900DS 112048 3900DSC Baseboard Sections STANDARD WHITE OUTSIDE CORNER INSIDE CORNER COMMERCIAL BROWN DESCRIPTION UPC# 686334 MODEL UPC# 686334 MODEL 112154 39BS28 112215 39BS28C 28” 112161 39BS36 112222 39BS36C 36” 112178 39BS48 112239 39BS48C 48” 112185 39BS60 112246 39BS60C 112192 39BS72 112253 39BS72C 72” 112208 39BS96 112260 39BS96C 96” 115094 39BS120 115100 39BS120C 120” 111911 3900-ICS 112017 3900-ICSC Inside Corner 111928 3900-OCS 112024 3900-OCSC Outside Corner 111935 3900-CS 112031 3900-CSC Control Section SECTION Blank Section SIZE 60” - Outside and inside corner sections are 6” on longest side Dimension Wireway Covers (White Units Only) TEMPERATURE LIMITING DEVICE 3.00” 8.50” 1.43 4” Blank UPC# 686334 MODEL LENGTH SHIP WT. (LBS) 112284 3900WW28 28” 2 112291 3900WW36 36” 2.5 112307 3900WW48 48” 3.5 112314 3900WW60 60” 4.5 112321 3900WW72 72” 5.5 112338 3900WW96 96” 7.5 115117 3900WW120 120” 7.5 4.10 2.42 1.60 WIRE NUT 2.1 51 2900HA Series Electric Baseboard - High Altitude Convection Heater Features 52 • Available in white or ivory with Aluminum heating element and Aluminum fins. • Painted 22 gauge steel front with 20 gauge junction boxes located on each end of the heater - junction boxes contain quick connect cable clamps and 6” ground lead wires. • Over-temperature thermal limit extends entire length of heated area. • A full length wireway provided along the back of the heater. • Optional enclosed conduit wireway available. • Heater can be mounted to the wall by using the key hole knockouts every 4” at the back of the heater. • Optional In-Built thermostats field installed in the junction box. • HEIGHT: 6” DEPTH: 2-1/2” • Ivory available with extended lead times-consult factory. Manufactured in U.S.A. Standard Models UPC# 686334 101226 101233 101240 101257 101264 101271 101288 101295 101301 101318 101325 101332 101349 101356 101363 101370 101387 101394 101400 101417 101424 101431 101448 101455 101462 101479 101486 101493 101509 101516 101523 101578 101585 101592 101608 101653 101660 101677 101684 WHITE MODEL E2903-024HAW F2903-024HAW H2903-024HAW G2903-024HAW E2905-028HAW F2905-028HAW H2905-028HAW G2905-028HAW E2906-036HAW F2906-036HAW H2906-036HAW G2906-036HAW E2907-040HAW F2907-040HAW H2907-040HAW G2907-040HAW E2910-048HAW F2910-048HAW H2910-048HAW G2910-048HAW G2907-048HAW E2912-060HAW F2912-060HAW H2912-060HAW G2912-060HAW G2909-060HAW E2915-072HAW F2915-072HAW H2915-072HAW G2915-072HAW G2911-072HAW F2920-096HAW H2920-096HAW G2920-096HAW G2915-096HAW F2925-120HAW H2925-120HAW G2925-120HAW G2918-120HAW WATTS BTU’s VOLTS AMPS 375 375 375 / 281 375 / 281 500 500 500 / 375 500 / 375 600 600 600 / 450 600 / 450 750 750 750 / 563 750 / 563 1000 1000 1000 / 750 1000 / 750 750 1250 1250 1250 / 938 1250 / 938 938 1500 1500 1500 / 1125 1500 / 1125 1125 2000 2000 / 1500 2000 / 1500 1500 2500 2500 / 1875 2500 / 1875 1875 1275 1275 1275 / 955 1275 / 955 1706 1706 1706 / 1275 1706 / 1275 2040 2040 2040 / 1530 2040 / 1530 2550 2550 2550 / 1914 2550 / 1914 3413 3413 3413 / 2550 3413 / 2550 2550 4250 4250 4250 / 3189 4250 / 3189 3189 5100 5100 5100 / 3825 5100 / 3825 3825 6826 6826 / 5100 6826 / 5100 5100 8532 8532 / 6375 8532 / 6375 6375 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 277 120 208 240 / 208 277 / 240 277 120 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 3.1 1.8 1.6/1.4 1.6/1.2 4.2 2.4 2.1/1.8 1.8/1.6 5 2.9 2.5/2.2 2.2/1.9 6.3 3.6 3.1/2.7 2.7.2.6 8.3 4.8 4.2/3.6 3.6/3.1 3.4 10.4 6 5.2/4.5 4.5/3.9 3.4 12.5 7.2 6.3/4.7 5.4/4.7 4.1 9.6 8.3/7.2 7.2/6.3 5.4 12 10.4/9.0 9.0/7.8 6.8 HEATER LENGTH (IN) WT. (LBS.) 24 5 28 6 36 7 40 8 48 10 60 12 72 14 96 18 120 22 2900A Series - International Models UPC# 686334 115766 115773 115780 115977 115803 115810 115827 115834 115841 115858 115865 115872 115889 115896 115902 118002 118033 118040 WHITE MODEL M2903-24AWi H2903-24AWi M2905-28AWi H2905-28AWi M2906-36AWi H2906-36AWi M2907-40AWi H2907-40AWi M2910-48AWi H2910-48AWi M2912-60AWi H2912-60AWi M2915-72AWi H2915-72AWi M2917-84AWi H2917-84AWi M2925-120AWi H2920-120AWi Wireway Length Same As Baseboard Length WATTS BTU’s 375 1275 500 1706 600 2040 750 2550 1000 3413 1250 4250 1500 5100 1750 5950 2500 8532 VOLTS 220 240 220 240 220 240 220 240 220 240 220 240 220 240 220 240 220 240 HEATER LENGTH (IN) WEIGHT (LBS) 24” 10 28” 11 36” 11.5 40” 13 48” 14 60” 16 72” 19 80” 22 120” 31 2900S Series Electric Baseboard - Stainless Steel Element Convection Heater Features • Available in white or ivory with stainless steel heating element and Aluminum fins. • Painted 22 gauge steel front with 20 gauge junction boxes located on each end of the heater - junction boxes contain quick connect cable clamps and 6”ground lead wires. • Over-temperature thermal limit extends entire length of heated area. • A full length wireway provided along the back of the heater - enclosed conduit available. • Heater can be mounted to the wall by using the key hole knockouts every 4” at the back of the heater. • Optional In-Built thermostats field installed in the junction box. • HEIGHT: 6” DEPTH: 2-1/2” Manufactured in U.S.A. Standard Models UPC IVORY UPC WHITE 686334 MODEL 686334 MODEL 104302 104319 104326 104333 104340 104357 104364 104371 104388 104395 104401 104418 104425 104432 104449 104456 104463 104470 104487 104494 104500 104517 103008 103015 103022 103039 103046 103053 103060 103077 103084 103091 103107 103114 103121 103138 103145 103152 103169 103213 103220 103237 103244 E2903-024S F2903-024S H2903-024S G2903-024S E2905-028S F2905-028S H2905-028S G2905-028S E2906-036S F2906-036S H2906-036S G2906-036S E2907-040S F2907-040S H2907-040S G2907-040S E2910-048S F2910-048S H2910-048S G2910-048S G2907-048S E2912-060S F2912-060S H2912-060S G2912-060S G2909-060S E2915-072S F2915-072S H2915-072S G2915-072S G2911-072S F2917-084S H2917-084S G2917-084S G2913-084S F2920-096S H2920-096S G2920-096S G2915-096S F2925-120S H2925-120S G2925-120S G2918-120S 104999 105002 105019 105026 105033 105040 105057 105064 105071 105088 105095 105101 105118 105125 105132 105149 105156 105163 105170 105187 105194 105200 105217 105224 105231 105248 105255 105262 105279 105286 105293 105309 105316 105323 105330 105347 105354 105361 105378 105422 105439 105446 105453 E2903-024SW F2903-024SW H2903-024SW G2903-024SW E2905-028SW F2905-028SW H2905-028SW G2905-028SW E2906-036SW F2906-036SW H2906-036SW G2906-036SW E2907-040SW F2907-040SW H2907-040SW G2907-040SW E2910-048SW F2910-048SW H2910-048SW G2910-048SW G2907-048SW E2912-060SW F2912-060SW H2912-060SW G2912-060SW G2909-060SW E2915-072SW F2915-072SW H2915-072SW G2915-072SW G2911-072SW F2917-084SW H2917-084SW G2917-084SW G2913-084SW F2920-096SW H2920-096SW G2920-096SW G2915-096SW F2925-120SW H2925-120SW G2925-120SW G2918-120SW WATTS BTU’s VOLTS AMPS 375 375 375 / 281 375 / 281 500 500 500 / 375 500 / 375 600 600 600 / 450 600 / 450 750 750 750 / 563 750 / 563 1000 1000 1000 / 750 1000 / 750 750 1250 1250 1250 / 938 1250 / 938 938 1500 1500 1500 / 1125 1500 / 1125 1125 1750 1750 / 1313 1750 / 1313 1313 2000 2000 / 1500 2000 / 1500 1500 2500 2500 / 1875 2500 / 1875 1875 1275 1275 1275 / 955 1275 / 955 1706 1706 1706 / 1275 1706 / 1275 2040 2040 2040 / 1530 2040 / 1530 2550 2550 2550 / 1914 2550 / 1914 3413 3413 3413 / 2550 3413 / 2550 2550 4250 4250 4250 / 3189 4250 / 3189 3189 5100 5100 5100 / 3825 5100 / 3825 3825 5950 5950 / 4464 5950 / 4464 4464 6826 6826 / 5100 6826 / 5100 5100 8532 8532 / 6375 8532 / 6375 6375 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 277 120 208 240 / 208 277 / 240 277 120 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 3.1 1.8 1.6/1.4 1.6/1.2 4.2 2.4 2.1/1.8 1.8/1.6 5 2.9 2.5/2.2 2.2/1.9 6.3 3.6 3.1/2.7 2.7.2.6 8.3 4.8 4.2/3.6 3.6/3.1 3.4 10.4 6 5.2/4.5 4.5/3.9 3.4 12.5 7.2 6.3/4.7 5.4/4.7 4.1 8.4 7.3/6.3 6.3/5.5 4.7 9.6 8.3/7.2 7.2/6.3 5.4 12 10.4/9.0 9.0/7.8 6.8 HEATER WT. LENGTH (LBS.) (IN) 24 5 28 6 36 7 40 8 48 10 60 12 72 14 84 16 96 18 120 22 53 2900C Series Electric Baseboard - Heavy Duty Commercial Convection Heater Features 54 • • • • • • Manufactured in U.S.A. • • Bankers bronze with stainless steel heating element and Aluminum fins. Powder coated 22 gauge steel front with 20 gauge junction boxes located on each end of the heater - junction boxes contain quick connect cable clamps and 6” ground lead wires. Standard inlet and outlet wire guards. Over-temperature thermal limit extends entire heated length of unit. A full length wireway provided along the back of the heater. Heater can be mounted to the wall by using the key hole knockouts every 4” at the back of the heater. Optional In-Built thermostats field installed in the junction box. HEIGHT: 6” DEPTH: 2-1/2” Standard Models UPC# 686334 103831 103848 103855 103862 103879 103886 103893 103909 103916 103923 103930 103947 103954 103961 103978 103985 103992 104005 104012 104029 104036 104043 104050 104067 104074 104081 104098 104104 104111 104128 104135 104142 104159 104166 104173 104180 104197 104203 104210 104265 104272 104289 104296 BRONZE MODEL E2903-024C F2903-024C H2903-024C G2903-024C E2905-028C F2905-028C H2905-028C G2905-028C E2906-036C F2906-036C H2906-036C G2906-036C E2907-040C F2907-040C H2907-040C G2907-040C E2910-048C F2910-048C H2910-048C G2910-048C G2907-048C E2912-060C F2912-060C H2912-060C G2912-060C G2909-060C E2915-072C F2915-072C H2915-072C G2915-072C G2911-072C F2917-084C H2917-084C G2917-084C G2913-084C F2920-096C H2920-096C G2920-096C G2915-096C F2925-120C H2925-120C G2925-120C G2918-120C WATTS BTU’s VOLTS AMPS 375 375 375 / 281 375 / 281 500 500 500 / 375 500 / 375 600 600 600 / 450 600 / 450 750 750 750 / 563 750 / 563 1000 1000 1000 / 750 1000 / 750 750 1250 1250 1250 / 938 1250 / 938 938 1500 1500 1500 / 1125 1500 / 1125 1125 1750 1750 / 1313 1750 / 1313 1313 2000 2000 / 1500 2000 / 1500 1500 2500 2500 / 1875 2500 / 1875 1875 1275 1275 1275 / 955 1275 / 955 1706 1706 1706 / 1275 1706 / 1275 2040 2040 2040 / 1530 2040 / 1530 2550 2550 2550 / 1914 2550 / 1914 3413 3413 3413 / 2550 3413 / 2550 2550 4250 4250 4250 / 3189 4250 / 3189 3189 5100 5100 5100 / 3825 5100 / 3825 3825 5950 5950 / 4464 5950 / 4464 4464 6826 6826 / 5100 6826 / 5100 5100 8532 8532 / 6375 8532 / 6375 6375 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 120 208 240 / 208 277 / 240 277 120 208 240 / 208 277 / 240 277 120 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 208 240 / 208 277 / 240 277 3.1 1.8 1.6 / 1.4 1.6 / 1.2 4.2 2.4 2.1 / 1.8 1.8 / 1.6 5.0 2.9 2.5 / 2.2 2.2 / 1.9 6.3 3.6 3.1 / 2.7 2.7 / 2.6 8.3 4.8 4.2 / 3.6 3.6 / 3.1 3.4 10.4 6.0 5.2 / 4.5 4.5 / 3.9 3.4 12.5 7.2 6.3 / 4.7 5.4 / 4.7 4.1 8.4 7.3 / 6.3 6.3 / 5.5 4.7 9.6 8.3 / 7.2 7.2 / 6.3 5.4 12.0 10.4 / 9.0 9.0 / 7.8 6.8 HEATER LENGTH (IN) WEIGHT (LBS) 24 5 28 6 36 7 40 8 48 10 60 12 72 14 84 16 96 18 120 22 International Models UPC# 686334 118057 118064 118071 118088 118095 118101 118118 118125 118132 118149 118156 118163 118170 118187 118194 118200 118217 118224 118231 118248 BRONZE MODEL M2903-024CI H2903-024CI M2905-028CI H2905-028CI M2906-036CI H2906-036C M2907-040CI H2907-040C M2910-048CI H2910-048CI M2912-060CI H2912-060C M2915-072CI H2915-072CI M2917-084CI H2917-084CI M2920-096CI H2920-096CI M2925-120CI H2925-120CI WATTS BTU’s 375 1275 500 1706 600 2040 750 2550 1000 3413 1250 4250 1500 5100 1750 5950 2000 6826 2500 8532 VOLTS AMPS 220 240 220 240 220 240 220 240 220 240 220 240 220 240 220 240 220 240 220 240 1.7 240 2.3 2.1 2.7 2.5 3.4 3.1 4.6 4.2 5.7 5.2 6.8 6.3 8.0 7.3 9.1 8.3 11.4 10.4 HEATER LENGTH (IN) WEIGHT (LBS) 24 5 28 6 36 7 40 8 48 10 60 12 72 14 84 16 96 18 120 22 Electric Baseboard - Accessories In-Built Thermostat Kits- With Two Cover Plates IVORY & WHITE 55 WEIGHT (LBS) DESCRIPTION UPC 686334 MODEL NUMBER 105460 TBS SPST-In-Built 22A @ 120-240V 18A @ 277V 502702 TBS-TP SPST-In-Built 22A @ 120-240V 18A @ 277V Tamperproof 105477 TBD DPST-In-Built 22A @ 120-240V 18A @ 277V 502719 TBD-TP DPST-In-Built 22A @ 120-240V 18A @ 277V Tamperproof 1/2 lbs. 1/2 lbs. Field Installed Accessories IVORY DESCRIPTION Disconnect Switch, 20 Amp, 120-277V WHITE BANKERS BRONE UPC 686334 MODEL UPC 686334 MODEL UPC 686334 MODEL 106108 DS 106115 DSW 106122 DSB WEIGHT (LBS) 1 lb. Corner Sections 105491 CS 105507 CSW 105514 CSB 1” Joiner Kits 105521 JK 105538 JKW 105545 JKB 1/4 lb. 6” Blank Relay Section (Relay Not Included)** 105552 LVRS 105569 LVRSW 105576 LVRSB 1 1/2 lbs. Receptacle Section (Baseboard Mounted) 15 Amp 120 VAC 105583 BDR115 105590 BDR115W 105606 BDR115B 1/4 lb. Receptacle Section (Mounted in 6” Blank) 15 Amp 120 VAC 105613 DR115 105620 DR115W 105637 DR115B Transfer Switch (Mounted in 6” Blank) 16 Amp 120 VAC 105644 SR120 105651 SR120W 105668 SR120B Transfer Switch (Mounted in 6” Blank) 16 Amp 240 VAC 105675 SR220 105682 SR220W 105699 SR220B 2 lbs. **Not for use with 24A06G-1 relay. Optional Wireway Covers Blank Sections UPC 686334 MODEL BASEBOARD LENGTH (in.) COVER LENGTH (in.) WEIGHT (LBS) 105705 WWA01 24 20 1 105712 WWA02 28 24 1.5 105729 WWA03 36 32 2 105736 WWA04 40 36 2.5 105743 WWA05 48 44 105750 WWA06 60 105767 WWA07 105774 LENGTH IVORY UPC MODEL WHITE UPC MODEL BANKERS BRONZE WEIGHT (LBS) UPC MODEL 24” 105804 BBS024A 105903 BBS024AW 106009 BBS024C 5 28” 105811 BBS028A 105910 BBS028AW 106016 BBS028C 5 1/2 36” 105828 BBS036A 105927 BBS036AW 106023 BBS036C 6 40” 105835 BBS040A 105934 BBS040AW 106030 BBS040C 7 3 48” 105842 BBS048A 105941 BBS048AW 106047 BBS048C 8 56 4 60” 105859 BBS060A 105958 BBS060AW 106054 BBS060C 10 72 68 5 72” 105866 BBS072A 105965 BBS072AW 106061 BBS072C 12 WWA08 84 80 6 84” 105873 BBS084A 105972 BBS084AW 106078 BBS084C 15 105781 WWA09 96 92 7 96” 105880 BBS096A 105989 BBS096AW 106085 BBS096C 17 105798 WWA00 120 116 8 120” 105897 BBS120A 105996 BBS120AW 106092 BBS120C 20 9100 Series - Radius Front Draft Barrier Heater ETL listed up to 250 Watts / foot for industrial, commercial, or residential applications. • • • • • • • Manufactured in U.S.A. • • HOW TO DESIGNATE A MODEL: E 91 96 Element Volts E = 120 F = 208 G = 277 H = 240 Model Series 91 Features Standard colors, white or ivory. “UNI-LOCK” construction allows snap-fit, 2 piece installation. Units can be controlled by optional In-Built thermostat or can be constructed with relays and / or transformers for low voltage or line voltage wall thermostats Thermal protection by full length manual reset linear limits Optional duplex receptacle section Wiring junction boxes on each end of the unit Custom colors and finishes available (consult factory) Limited by max Amp draw of 25 Amps (with no controls). Additional charges may be incurred if changes are made after production has begun - consult factory. 250 ITS PD Watts Per Foot 100, 125, 150, 165, 187, 200, or 250 Heater Length (inches) 28, 36, 48, 60, 72, 84, 96, 108, or 120 Control Options Factory Installed Refer to Pg. 60 Accessories PD = Pedestal DR = Receptacle WM = Screen Product Description TECHNICAL INFORMATION TECHNICAL INFORMATION Bottom Height Top Depth 3 1/8” Min Mounting Height 3” Length 28” to 120” in 1’ increments Max Watts / Foot 250 Aluminum Max Allowable Amps 25 Amps (20 Amps with disconnect) Cabinet Material Material Gauge Voltage / Phase 120V/208V/240V/277V Single Phase Optional Controls That Can Be Built Into Unit Thermostat and Disconnect Switch (Control Section Required for Relays) Air Intake Air Discharge UNIT LENGTH MODEL MODEL UNIT LENGTH 9128 28” 91BS012 12” 9136 36” 91BS024 24” 91BS036 36” 91BS048 48” 91BS060 60” 91BS072 72” 91BS084 84” 91BS096 96” 48” 9160 60” 9172 72” 9184 84” 9196 96” 91108 108” 91BS108 108” 91120 120” 91BS120 120” BLANK SECTION 9148 Note: All models are suitable for International use 4 1/2” 14 Factory Installed Accessories Standard Models HEATER 56 SUFFIX DESCRIPTION DR Duplex Receptacle in 4” Extended Enclosure (not available with 120” heater) 28” through 60” - 2 Required PD 72” through 96” - 3 Required 108” through 120” - 4 Required WM 1/4” wire mesh under grill Field Installed Accessories MODEL DESCRIPTION 9100IC Inside Corner Section 90° or 135° 9100OC Outside Corner Section 90° or 135° 9100EC Right or Left End Cap 9100 Series - Radius Front Draft Barrier Heater Product Specifications CABINET 9100 Series shall be constructed of 14 gauge extruded 6063 Aluminum heat treated to T5 hardness. The uni-lock construction shall allow easy installation and access to back plate for wiring. The snap-fit front cover makes installation and service very simple. Custom factory enclosures to 1/16 inch increments are built for exact wall to wall fit up to 10 foot enclosure lengths. The 14 gauge back plate will have electrical knockouts for incoming power on each end adjacent to junction box. Pedestal mounted units will have incoming power connection through the pedestal on bottom of unit and will have smooth back for optional finished back. The die punched front cover will have no screw heads or fasteners. ELEMENTS High mass sheathed element construction with Nickel-Chromium resistance wire embedded in compacted efficient die-electric to ensure proper heat transfer. Aluminum fins mechanically bonded to stainless steel tube allows for increased surface area and even heat transfer. LIMIT CONTROLS Manual reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded. WIRING Wiring shall be in either end of the enclosure. Wiring can be in the junction box or optional control section if additional controls are needed. Pedestal mounted units shall have 1-1/4” hole through the pedestal and in the bottom of the enclosure for incoming power wiring. All heaters have a factory supplied built in raceway for wiring from either end of the heater or for wiring of continuous heater connections. CONTROLS Optional controls include single or double pole thermostat and disconnect switch that are factory wired in enclosed junction box on each end of heater enclosure. Relay, transformer relay and duplex receptacle options shall be mounted in extended length control section. Control section will add to heater enclosure length. The control section for the duplex receptacle will add 4” to enclosure length. The control section for other optional components or combinations of components will have two options (6” or 12”) depending on controls required. APPLICATION The 9100 series is ETL listed for commercial, industrial or residential applications on all units up to 250 Watts per foot. Product Dimensions 3-1/8" 1-1/8" BACK VIEW OUTSIDE CORNER SECTION 1-1/2" 2-7/16" TYP Ø .395 (TYP) 1-9/16" 4-1/2" 1-9/16" 15/16" INSIDE CORNER SECTION 6.0” 3-1/8" 1-9/16" 2-1/16" 3" MINIMUM 3" FINISHED FLOOR WALL MOUNT 6.0” PEDESTAL MOUNT 3-1/16” PEDESTAL BASE 57 9300 Series - Radius Front Draft Barrier Heater ETL listed up to 750 Watts / foot for industrial or commercial applications. • • • • • • • • • Manufactured in U.S.A. HOW TO DESIGNATE A MODEL: E 93 Model Series 93 Features Leed and green compliance, 1 and 3 phase applications Industrial or commercial applications Standard color: Bankers Bronze (powder coated) Also available in other standard TPI colors and custom colors for an additional charge Uni-lock construction for snap fit 2 piece installation Temperature control can be in-built or wall mounted Thermal protection by full length manual reset linear limits Optional accessories include: duplex receptacle, and inside or outside corner sections for wall to wall custom fit. Additional charges may be incurred if changes are made after production has begun - consult factory. 96 Heater Length (inches) 28, 36, 48, 60, 72, 84, 96, 108, or 120 B 250 Inlet B = Bottom F = Front ITS PD Watts Per Foot Per Element 100, 125, 150, 165, 187, 200, or 250 Control Options Refer to Pg. 60 of TPI Heat catalog. Factory Installed Accessories PD = Pedestal DR = Receptacle WM = Screen Three Phase Single Phase Element Volts E = 120 F = 208 H = 240 G = 277 L = 347 P1 = 480 U1 = 600 J = 208 K = 240 P3 = 480 U3 = 600 Note: 480V single phase units minimum 36” heated length; 600V single phase units minimum 48” heated length 347-480-600 single phase and all three phase units are built with low voltage option factory installed Product Description Air Intake Air Discharge Min Mounting Height Max Watts / Foot Max Allowable Amps Voltage / Phase TECHNICAL INFORMATION Bottom / Front Top 3” for bottom intake / 0” for front intake 750 25 without relay, 40 with relay 120V/208V/240V/277V/347V,480V,600V Single Phase 208V,240V,480V,600V Three Phase TECHNICAL INFORMATION Height 7.5” Depth 6.15” Length 28” to 120” in 1’ increments Cabinet Material Material Gauge Aluminum Optional Controls That Can Be Built Into Unit MODEL UNIT LENGTH 12 Thermostat, Disconnect Switch, Transformer (Control Section Required for Relays) Factory Installed Accessories Standard Models MODEL UNIT LENGTH SUFFIX DR DESCRIPTION Duplex Receptacle in 4” Extended Enclosure (not available with 120” heater) 28” through 60” - 2 Required 72” through 96” - 3 Required 108” through 120” - 4 Required 9328 28” 93BS012 12” 9336 36” 93BS024 24” 9348 48” 93BS036 36” 9360 60” 93BS048 48” 9372 72” 93BS060 60” 93BS072 72” 9384 84” 93BS084 84” 9396 96” 93BS096 96” MODEL DESCRIPTION 93108 108” 93BS108 108” 9300IC Inside Corner Section 90° or 135° 93120 120” 93BS120 120” 9300OC Outside Corner Section 90° or 135° 9300EC Right or Left End Cap Blank Section Heater 58 Note: All models are suitable for International use PD WM 1/4” wire mesh under grill 30 Amp/240V Disconnect Switch 40 Amp/600V Disconnect Switch Note: If using line voltage thermostat on 1 phase heaters, you cannot exceed 25 Amps due to Amp rating of thermostat. 347, 480, and 600V can use 30 Amps with in-built thermostat. IDS Field Installed Accessories 9300 Series - Radius Front Draft Barrier Heater Product Specifications CABINET 9300 Series shall be constructed of 12 gauge extruded 6063 Aluminum heat treated to T5 hardness. The uni-lock construction shall allow easy installation and access to back plate for wiring. The snap-fit front cover makes installation and service very simple. Custom factory enclosures to 1/16 inch increments are built for exact wall to wall fit up to 10 foot enclosure lengths. The 12 gauge back plate will have electrical knockouts for incoming power on each end adjacent to junction box. Pedestal mounted units will have incoming power connection through the pedestal on bottom of unit and will have smooth back for optional finished back. The die punched front cover will have no screw heads or fasteners. ELEMENTS High mass sheathed element construction with Nickel-Chromium resistance wire embedded in compacted efficient die-electric to ensure proper heat transfer. Aluminum fins mechanically bonded to stainless steel tube allows for increased surface area and even heat transfer. LIMIT CONTROLS Manual reset hydraulic thermal overload covers full length of heating element and shuts down heater when safe operating temperatures are exceeded. WIRING Wiring shall be in either end of the enclosure. Wiring can be in the junction box or optional control section if additional controls are needed. Pedestal mounted units shall have 1-1/4” hole through the pedestal and in the bottom of the enclosure for incoming power wiring. All heaters have a factory supplied built in raceway for wiring from either end of the heater or for wiring of continuous heater connections. CONTROLS Optional controls include single or double pole thermostat and disconnect switch that are factory wired in enclosed junction box on each end of heater enclosure. Relay, transformer relay and duplex receptacle options shall be mounted in extended length control section. Control section will add to heater enclosure length. The control section for the duplex receptacle will add 4” to enclosure length. The control section for other optional components or combinations TYP of components will have two options (6” or 12”) depending on controls required. 6.15 6.15 2716" 7.500 7.500 Ø .395 (TYP) 1 3 16" APPLICATION PEDESTAL BASE The 9300 series is ETL listed for commercial or industrial applications on all units up to 750 Watts per foot on single phase units. 3 Phase units have a minimum of 300 Watts per foot. 3" 3" MINIMUM FINISHED FLOOR 21516" Product Dimensions 6.15 6.15 2716" TYP 7.500 7.500 Ø .395 (TYP) PEDESTAL BASE 3" 3" MINIMUM 6.15 12.0 OUTSIDE CORNER3 SECTION 1 6.15 2716" " 16 TYP 7.500 7.500 Ø .395 (TYP) 1 3 16" FINISHED FLOOR 2 15 " 16 12.0 12.0 PEDESTAL BASE 3" 3" MINIMUM FINISHED FLOOR 21516" INSIDE CORNER SECTION 12.0 12.0 59 Draft Barrier Heaters - General Product Information 60 All Draft Barrier Heaters, unless otherwise noted, are build to order items. Consult factory for lead times. Additional charges may be incurred if changes are made after production has begun - consult factory. Electric Draft Barrier Features • “UNI-LOCK” construction allows snap-fit, 2 piece installation • Heavy Gauge Aluminum Extruded enclosures, 6063 heat treated to T-5 hardness a. DBT/DBF & RDBT-PD-12 gauge front & back b. DBCT/DBCF- 10 gauge Front & Back c. CB-14 gauge Front & Back • ASHDB Series is 16 gauge Steel Front with 18 Steel gauge back • 1/4” pencil proof discharge louvers • Thermal protection by full length linear limits • Multiple heaters, factory wired on same back plate, available in up to 10’ lengths • Totally enclosed junction boxes • Custom colors and finishes available (See Chart ) • Enclosures available for hydronic heating coils (consult factory for more information ) How To Designate A Model Digit (Example) MODEL NUMBER DESIGNATION - “ASI” DRAFT BARRIER Digit 1= DBT Series Model Number ( DBT/DBF, CB, Etc.) Use if Pedestals are Required* Digit 2= 2’ to 5’ Heaters require 2 pedestals PD 6’ to 8’ Heaters require 3 pedestals 9’ & 10’ Heaters require 4 pedestals Heated Length of Heater Digit 3= 4 (for extended enclosure, specify amount of required enclosure on order write up, IE: 4’ Heated length w/ 2’6” of extended enclosure) Digit 4= 250 Digit 5= ITS (etc) Wattage per Linear foot ( may not exceed allowable wattages on specific models, refer to catalogue page to verify maximum WPF) Control Options ; Refer to List Price chart for available options ( Verify on each model which options may be factory installed ) Completed example: DBT-PD-4250-ITS NOTE: • Extended enclosures and Blank Sections are NOT punched. When a Control Section is specified, ALWAYS allow for an extended enclosure to compensate for the 6” or 12” length of the Section required. • Note on order when finished backs are required and add list adder to model list. • Total heater amperage must not exceed the 25-Amp rating of the high temperature limit at any voltage or wattage. This applies to all Sill Line Model Series. Voltage & Wattage Specification Voltage Standard Wattages Per Foot Heater Lengths 120-277 125,165,187,200,250*,333*,375* 2’ through 10’ *Units with Extended Enclosures may require more Pedestals than standard length, must verify length of heater after extended enclosures for total amount of pedestals. NOTE: All bottom inlet units must be mounted a minimum of 3 inches above finished floor. Dual element models DBCT/DBCF and ASHDB may have any combination of elements. All elements are single phase. Custom wattages are available within certain parameters, consult factory for more information. Control Options CUSTOM PAINT COLORS Durable Powder Coat Paint Finish Suffix Designation Description CS 6 6” control section / will contain up to 2 control options CS 12 12” control section / will contain up to 3 control options ITS Single Pole, 25 Amp integral thermostat, 120,208,240 & 277 Volts Black Bankers Bronze - standard color Eggshell White ITD Double Pole, 25 Amp integral thermostat, 120,208,240 & 277 Volts Gray IDS Double Pole Disconnect, 20 Amp, 120, 208, 240 & 277 Volts IDS 30 30 Amp disconnect (9300 Series) Beige IDS 40 40 Amp disconnect (9300 Series) LVTR Low voltage controls (trans & relay) PR 120-277/24 PR 120-277/120 PR 120-277/240 Power Relay, 18 Amp tested, Must specify coil voltage Single Pole Single Pole, rated 25 Amps, 120 to 240 Volts, ATR* Contacts rated up to 277 Volts (must specify ) Coils are 24 Volt; 24 Volt transformer * Not suitable for International use Note: Please refer to each model to verify how many controls may be integrally mounted, Control sections will add length to the heater. Must use control section with PR 240/24, PR 208/24, 208/208 and ATR Note: If using line voltage thermostat on single phase heaters you cannot exceed 25 Amps due to Amp rating of thermostat. 347, 480, and 600V models can use up to 30 Amps with in-built thermostat. Bronze Anodized* *simulated powder coat finish Special Colors (5 lb. Increment) ANODIZING* * 204R1 Clear; 313R1 Bronze and Black DBF / DBT Series DBCT / DBCF Series Manufactured in U.S.A. 5’ DBF-6/DBT-6 6’ DBF-7/DBT-7 7’ DBF-8/DBT-8 8’ DBF-9/DBT-9 9’ DBF-10/DBT-10 10’ Extended Enclosure (no color on finished back) Blank Sections DBF/DBT-100BS 1’ DBF/DBT-200BS 2’ DBF/DBT-300BS 3’ DBF/DBT-400BS 4’ DBF/DBT-500BS 5’ DBF/DBT-600BS 6’ DBF/DBT-700BS 7’ DBF/DBT-800BS 8’ DBF/DBT-900BS 9’ DBF/DBT-1000BS 10’ Accessories Color Availability DBF/DBT IC / Inside Corner Section 90 - 180 Degrees Accessories Painted Bronze DBF/DBT IECR / Inside Fitting Right End Cap DBF/DBT IECL / Inside Fitting Left End Cap DBF/DBT WT / 2”- 6” Wall Trim DBF/DBT SP / 1 1/2” Splice Plate DBF/DBT MF / Mullion Front up to 1’ DBF/DBT IF / Inside Filler up to 1’ 3/4” Conduit Raceway (standard is 1/2”) Mesh / 1/4” Wire Mesh under Grill Pedestals - specify 2” or 3” See Chart for required amount per Heater Color Anodized DBF/DBT ECR / Right Hand End Cap DBF/DBT ECL / Left Hand End Cap Clear Anodized DBF/DBT OC / Outside Corner Section 180 - 270 Degrees - 6” longest side NOTE: DBF/DBT Series will permit a Thermostat mounted on one side and a Disconnect on the other side, more or other controls require a 6” or 12” control section. Typically, thermostats are mounted on left side of heater. Control Section will add to length of heater. DBCT/DBCF IC / Inside Corner Section 90 - 180 Degrees DBCT/DBCF OC / Outside Corner Section 180 - 270 Degrees - 6” longest side DBCT/DBCF ECR / Right End Plate DBCT/DBCF ECL / Left End Plate DBCT/DBCF IECR/ Right End Plate (inside fit) DBCT/DBCF IECL/ Left End plate (inside fit) DBCT/DBCF WT / Wall Trim 2” - 6” DBCT/DBCF SP / 1 1/2” Splice Plate DBCT/DBCF IF / Inside Filler (up to 1’) 3/4” Conduit Raceway (standard is 1/2”) Mesh / 1/4” Wire Mesh under Grill Pedestals - specify 2” or 3” See Chart for required amount per Heater Painted Bronze 4’ DBF-5/DBT-5 to 250 DBCT-2/DBCF-2 2’ 251-750 to 250 DBCT-3/DBCF-3 3’ 251-750 to 250 DBCT-4/DBCF-4 4’ 251-750 to 250 DBCT-5/DBCF-5 5’ 251-750 to 250 DBCT-6/DBCF-6 6’ 251-750 to 250 DBCT-7/DBCF-7 7’ 251-750 to 250 DBCT-8/DBCF-8 8’ 251-750 to 250 DBCT-9/DBCF-9 9’ 251-750 to 250 DBCT-10/DBCF-10 10’ 251-750 Extended Enclosure (no color on finished back) Blank Sections DBCT/DBCF-100BS 1’ DBCT/DBCF-200BS 2’ DBCT/DBCF-300BS 3’ DBCT/DBCF-400BS 4’ DBCT/DBCF-500BS 5’ DBCT/DBCF-600BS 6’ DBCT/DBCF-700BS 7’ DBCT/DBCF-800BS 8’ DBCT/DBCF-900BS 9’ DBCT/DBCF-1000BS 10’ Color Availability (heater & finished back) Color Availability Painted Bronze DBF-4/DBT-4 WATTS/FT. Color Anodized 2’ 3’ Painted Bronze DBF-2/DBT-2 DBF-3/DBT-3 Color Availablility (heater & finished back) Color Anodized LENGTH Clear Anodized MODEL MODEL / LENGTH Color Anodized Cabinet Dimensions: 3-1/2” x 6” x 10’ Maximum Length Not suitable for residential applications above 150 Watts per foot. Built to order: consult factory for lead time. 61 DBCF Floor Mount DBCT Wall Mount Model-600 WPF Max. Model-750 WPF Max. Cabinet Dimensions: 5” x 7” x 10’ Maximum Length Not suitable for residential applications. Built to order: consult factory for lead time. Clear Anodized DBF Floor Mount Model-250 WPF Max. Clear Anodized DBT Wall Mount Model-300 WPF Max. Manufactured in U.S.A. NOTE: DBCT/DBCF Series will permit a Thermostat mounted on one side and Disconnect on the other side, more or other controls require a 6” or 12” control section. Typically, Thermostats are mounted on left side of heater. Control Section will add to the length of heater. DBTS Series Draft Barrier Heaters Features 62 Manufactured in U.S.A. • Bottom air intake. • Maximum watts per foot: 300. • Dimensions: Depth 2-5/8'” x Height 4" Length 2’ to 10'. • 14 gauge Aluminum housing. • Voltages: 120V / 208V / 240V / 277V - 1 Phase • No controls can be added without adding a control section and extended enclosure. Not suitable for residential applications. 150 watts Standard Models MODEL HEATER per foot maximum. Built to order: consult factory for lead time. MODEL LENGTH DBTS-2 2’ DBTS-3 3’ DBTS-4 4’ DBTS-5 5’ DBTS-6 DBTS-7 6’ BLANK SECTION DBTS-100BS 1’ DBTS-200BS 2’ DBTS-300BS 3’ DBTS-400BS 4’ DBTS-500BS 5’ DBTS-600BS 6’ DBTS-700BS 7’ DBTS-800BS 8’ DBTS-900BS 9’ DBTS-1000BS 10’ 7’ DBTS-8 8’ DBTS-9 9’ DBTS-10 10’ Accessories MODEL DESCRIPTION DBTS IC Inside Corner Section 90° - 180° DBTS OC Outside Corner Section 180° - 270° - 6” longest side DBTS ECR Right Hand End Cap DBTS ECL Left Hand End Cap DBTS IECR Inside Fitting Right End Cap DBTS IECL Inside Fitting Left End Cap DBTS WT Wall Trim 2” - 6” DBTS SP Splice Plate 1 1/2” DBTS MF Mullion Front up to 1’ 1/2” Conduit Raceway Note on order LENGTH Mesh 1/4” Wire Mesh under grill Pedestals - specify 2” or 3” ASHDB Series Manufactured in U.S.A. MODEL / LENGTH Painted Bronze Color Anodized Clear Anodized Accessories Color Availability RDBT-PDIC / Inside Corner Section 90 - 180 Degrees RDBT-PDOC / Outside Corner Section 180 - 270 Degrees - 6” longest side RDBT-PDIECR/Inside Fitting Right End Cap RDBT-PDIECL/Inside Fitting Left End Cap 3/4” Conduit Raceway (standard is 1/2”) Mesh - 1/4” Wire Mesh under Grill NOTE: RDBT-PD Series will permit a Thermostat mounted on one side and a Disconnect on the other side. More or other controls require a 6” or 12” control section. Typically, Thermostats are mounted on the left side of heater. Control Sections will add to length of heater. CB Series Cabinet Dimensions: 2-5/8” x 4-1/2” x 10’ Maximum Length NOTE: CB Series will permit either a Thermostat or a Disconnect on only one side of the heater. More or other controls require a control section. Typically, Thermostats are mounted on the right side of heater. Control Sections will add to length of heater. Painted Bronze Not suitable for residential applications. Bottom inlet only. Built to order: consult factory for lead time. CB-2 2’ CB-3 3’ CB-4 4’ CB-5 5’ CB-6 6’ CB-7 7’ CB-8 8’ CB-9 9’ CB-10 10’ Extended Enclosure (no color on finished back) Blank Sections CB-100BS 1’ CB-200BS 2’ CB-300BS 3’ CB-400BS 4’ CB-500BS 5’ CB-600BS 6’ CB-700BS 7’ CB-800BS 8’ CB-900BS 9’ CB-1000BS 10’ Color (heater & finished back) Color Anodized Manufactured in U.S.A. Length Clear Anodized Model Manufactured in U.S.A. WATTS/FT. Color Availability (heater & finished back) Painted Bronze to 250 ASHDB-2 2’ 251-500 to 250 ASHDB-3 3’ 251-500 to 250 ASHDB-4 4’ 251-500 to 250 ASHDB-5 5’ 251-500 to 250 ASHDB-6 6’ 251-500 to 250 ASHDB-7 7’ 251-500 to 250 ASHDB-8 8’ 251-500 to 250 ASHDB-9 9’ 251-500 to 250 ASHDB-10 10’ 251-500 Extended Enclosure (no color on finished back) Blank Sections ASHDB-8/20-100BS 1’ ASHDB-8/20-200BS 2’ ASHDB-8/20-300BS 3’ ASHDB-8/20-400BS 4’ ASHDB-8/20-500BS 5’ ASHDB-8/20-600BS 6’ ASHDB-8/20-700BS 7’ ASHDB-8/20-800BS 8’ ASHDB-8/20-900BS 9’ ASHDB-8/20-1000BS 10’ Accessories Color Availability ASHDB IC / Inside Corner Section 90 - 180 Degrees ASHDB OC / Outside Corner Section 180 - 270 Degrees - 6” longest side ASHDB ECR / Right End Cap ASHDB ECL / Left End Cap ASHDB SP / 1 1/2” Splice Plate ASHDB WT / 2” - 6” Wall Trim 3/4” Conduit Raceway ( standard is 1/2”) Mesh / 1/4” Wire Mesh under Grill Pedestals - Specify 2” or 3” See Chart for required amount per Heater NOTE: ASHDB Series will permit a Thermostat mounted on one side and a Disconnect on the other side, more or other controls require a 6” or 12” control section. Typically, Thermostats are mounted on left side of heater. Control Section will add to length of heater. Painted Bronze Painted Bronze 1’ 2’ 3’ 4’ 5’ 6’ 7’ 8’ 9’ 10’ Color Availability Color Anodized LENGTH 2’ 3’ 4’ 5’ 6’ 7’ 8’ 9’ 10’ Clear Anodized MODEL RDBT-PD-2 RDBT-PD-3 RDBT-PD-4 RDBT-PD-5 RDBT-PD-6 RDBT-PD-7 RDBT-PD-8 RDBT-PD-9 RDBT-PD-10 Extended Enclosure Blank Sections RDBT-PD-100BS RDBT-PD-200BS RDBT-PD-300BS RDBT-PD-400BS RDBT-PD-500BS RDBT-PD-600BS RDBT-PD-700BS RDBT-PD-800BS RDBT-PD-900BS RDBT-PD-1000BS Cabinet Dimensions: 5-1/2” x 8” thru 20” x 10’ Maximum Length. Cannot be Anodized 63 Accessories CB IC / Inside Corner Section 90 - 180 Degrees CB OC / Outside Corner Section 180 - 270 Degrees - 6” longest side CB ECR / Right End Cap CB ECL / Left End Cap CB WT / Wall Trim 2” - 6” CB SP / Splice Plate 1 1/2” CB MF / Mullion Front up to 1’ 1/2” Conduit Raceway Mesh / 1/4” Wire Mesh under Grill Pedestals - specify 2” or 3” See Chart for required amount per Heater Color Availability Painted Bronze Not suitable for residential applications. 300 Watts Per Foot Maximum. Pedestals included with unit. Rounded enclosure with flat top discharge. Special Build: consult factory for lead time. Not suitable for residential applications. 500 Watts per foot maximum. 16 gauge Steel enclosure, 18 gauge backplate. Heights may vary from 8” up to 20.” Bottom Intake / Top Discharge. Special build - consult factory for lead time. Color Anodized Cabinet Dimensions: 7” x 6” x 10’ Maximum Length Clear Anodized RDBT Series MR Series Heavy Duty Metal Sheath Electric Infrared Heater 64 Heavy Duty Overhead Infrared Heaters for Indoor Spot Heating, Zone or Total Area Heating Applications • High-Density radiant heat, with 60° symmetric heat pattern. • ETL Listed for suspended high-bay indoor Manufactured in U.S.A. applications MR-2/4 KW • Rugged straight metal sheath elements installed, great for high vibration areas. • Gold anodized Aluminum housing for efficient, long term reflectivity & corrosion resistance. • Terminal box with high-temp Silicone wire. • Single or three phase wiring. • ”L” brackets included for chain suspension, or rigid mounting. MR-6/13 KW MR Series Safety Note Ground fault protection must be used. To avoid potential hazards use model GF-SK-1 ground fault sensing switch with these heaters. This device is designed to provide a reliable way to quickly terminate power to the heaters in the event of a ground fault occurrence. Standard Models UPC# 686334 MODEL KW BTU’S VOLTS PHASE 135177 135184 135214 135221 135238 135245 135306 135320 135337 135344 135351 135368 135375 135382 135412 135429 135115 135122 135139 135153 135160 135252 135269 135283 135290 MR-212-1 MR-220-1 MR-224-1 MR-227-1 MR-248-1 MR-257-1 MR-420-1 MR-424-1 MR-427-1 MR-448-1 MR-457-1 MR-620-3 MR-624-3 MR-627-3 MR-648-3 MR-657-3 MR-1320-3 MR-1324-3 MR-1327-3 MR-1348-3 MR-1357-3 MR-2720-3 MR-2724-3 MR-2748-3 MR-2757-3 1.8* 6,143 1 2.0 6,826 120 208 240 277 480 600 208 240 277 480 600 208 240 277 480 600 208 240 277 480 600 208 240 480 600 4.5 6.0 15,359 20,478 13.5 46,076 27* 92,151 AMPS 3-Ph 1 N/A 1 3 or 1 3 3 or 1 3 Note: Some 3-Phase models can be field converted to single phase operation. 17.0 14.5 N/A 7.5 5.8 37.5 33.0 N/A 17.0 13.6 74.8 64.8 32.4 26.7 1-Ph WT. (Lbs.) 15.0 9.6 8.5 7.2 4.2 3.3 21.6 18.8 16.3 9.5 7.5 29.0 25.0 21.7 13.0 10.0 Optional Wireguards UPC# MODEL 686334 9.0 449090 HDWG-2 15.0 449069 HDWG-4 27.0 449076 HDWG-6 48.8 29.0 43.0 449083 HDWG-13 N/A 288.0 Crated 883047 HDWG-27 N/A Heavy Duty Metal Sheath Infrared Control Options CONTROL FEATURES: • (GF-SK-1) Positive “off” and built-in “on/off” rocker switch illuminates “red” during operation. • Controls cannot be mounted directly on unit. Must use 6” minimum threaded conduit. UPC MODEL DESCRIPTION 686334 RATING (VAC) Dimensions (In) Ht. Wd. Dp. WT. (lbs.) 486026 GF-SK-1 Ground Fault Sensing Switch 208V - 600V 50A 10.3 10.3 5.0 12 589376 DC-SK-1 Disconnect Switch 120V - 600V 50A 5.0 6.0 4.0 5 MR Series Heavy Duty Metal Sheath Electric Infrared Heater Note: The MR-27 Series includes (2) Terminal Box Assemblies, located on each end of the heater, requiring an electrical service to each end. MR-27 KW Manufactured in U.S.A. MR Series Dimensions & Reflector Pattern DIMENSIONS (in.) SERIES A B C LENGTH WIDTH DEPTH MR-2 28 9 7.25 MR-4 48.5 9 7.25 MR-6 30 19.88 7.5 MR-13 50.5 19.88 7.5 MR-27 96.75 28.25 14.88 60° Symmetric NOTE: Take into account that the MR Series is designed with a 60° symmetrical reflector heat pattern. The sizing chart can assist you based upon your mounting height. Mounting Clearances & Recommended Mounting Height Mounting Clearances All MR Models 24” from ceiling 36” from vertical surface & from another heater 72” from face of heater to combustible surface MR-27 Only 87” from face of heater to combustible surface Sizing Chart Product Specifications Heater Model Length Wide Coverage (Sq. Ft.) Watts / Sq. Ft. MR-2 8 8 64 31.3 MR-4 9 8 72 62.5 MR-2 11 10 110 18.2 MR-4 11 10 110 40.9 MR-6 12 10 120 50.0 MR-4 12 11.5 138 32.6 MR-6 14 12 168 35.7 MR-13 15 13 195 69.2 MR-6 16 14 224 26.8 MR-13 18 16 288 46.9 MR-6 18 16 288 20.8 MR-13 21 18 378 35.7 MR-27 24 19 456 59.2 MR-13 23 20 460 29.3 MR-27 28 20 560 48.2 20’ MR-27 28 23 644 41.9 24’ MR-27 33 27 891 30.3 30’ MR-27 41 32 1312 20.6 Mounting Height 8’ 10’ 12’ 14’ 16’ 18’ Recommended Mounting Height 1.8 & 2.0 KW 8’ - 10’ 4.5 KW 8’ - 12’ 6.0 KW 10’ - 14’ 13.5 KW 12’ - 16’ 27.0 KW 15’ - 30’ Housing: .040 Gold anodized Aluminum housing for efficient, long-term reflectivity and corrosion resistance. Highdensity radiant heat. Housing is ETL Listed for indoor, dry environment applications only. Reflector: 60 degree symmetric heat pattern. Elements: Rugged straight metal sheath elements. .430” diameter Incoloy 840 metal sheath. Nickel-Chrome alloy coiled filament imbedded within a Magnesium Oxide insulating powder and threaded end terminations. Available wattages in 1800, 2000, and 4500 Watts per element. Available in standard voltages from 120 to 600 Volts. Controls: Heavy Duty, Metal Sheath heaters are not manufactured with any control device on the unit. All controls and accessories should be specified as remote mounted. Please consult the technical sales department of factory for help in determining applicable controls. Please follow installation instructions that accompany each heater. Accessories: Wire guards and power contactor panels. 65 TH & THSS Series Mul-T-Mount Electric Infrared Heater 66 Overhead Infrared Heaters for Snow & Ice Control, Outdoor Spot Heating & All Indoor Heating Applications Product Description AVAILABLE IN 2 LAMP BROWN ENAMEL OR STAINLESS STEEL, OR 3 LAMP STAINLESS STEEL. • Listed for suspended, totally exposed (outdoor), high-bay (indoor) comfort heating and exterior snow & ice control applications. • Listed for recessed applications. • 20 gauge painted steel or stainless steel housings. • Gold anodized Aluminum reflectors & end caps. • 50% higher Watt densities for 3-element units. • 2-Lamp wiring, single phase. • 3-Lamp wiring, three or single phase. • Stainless steel models have non-corrosive housing, hardware and brackets; no ferrous metals used in the unit. Durable in harsh atmospheres & outdoor environments. • High temperature lead wires. • Clear Quartz Lamp(s) Included. Manufactured in U.S.A. New Feature: In-Built surface mounting brackets allows for fixture adjustment up to 45° horizontal tilt. 0 to 45o tilt @ 15o increments In-built surface mounting brackets attached to the top wiring channel. Product Dimensions Mul-TMount Series 222 342 462 223 343 463 A Length 24" 33" 46" 24" 33" 46" Dimensions (in.) B C Width Height 15" 10-7/8" 15" 10-7/8" 15" 10-7/8" 21-1/2" 10-7/8" 21-1/2" 10-7/8" 21-1/2" 10-7/8" D Mtg. Ctr. 23-1/2" 32-1/2" 45-1/2" 23-1/2" 34" 45-1/2" Mounting Clearances & Recommended Mounting Height Mounting Clearances 2 & 3 Lamp Models 2 Lamp Models 3 Lamp Models 3” from ceiling 24” from vertical surface 72” from face of heater to combustible surface 96” from face of heater to combustible surface Recommended Mounting Height 30° Symmetric & A30° Asymmetric Reflector Indoor 60° Symmetric & A60° Asymmetric Reflector Indoor 90° Symmetric Reflector - Indoor 30° Symmetric & A30° Asymmetric Reflector Outdoor 14’ - 30’ 12’ - 18’ 8’ - 12’ 8’ - 10’ TH & THSS Series Mul-T-Mount Electric Infrared Heater Reflector Patterns Product Specifications 30° Symmetric 30° Asymmetric 60° Symmetric 60° Asymmetric Series: 222, 342, 462 (Painted Version) 2-lamp 222, 342, 462 (Stainless Steel Version) 2-lamp 223, 343, 463 (Stainless Steel Version) 3-lamp Housing: 20 gauge Galvanized Steel with a baked on, brown enamel (painted) finish. Housing is ETL Listed for both indoor and totally exposed outdoor applications. 20 gauge Stainless Steel for durability and corrosion-resistance. Housing is ETL Listed for both indoor and totally exposed outdoor applications. Reflectors and End Caps: .040 Gold anodized Aluminum reflectors and end caps for superior reflectivity. Five choices of reflector patterns including 30 degree narrow (symmetric & asymmetric), 60 degree medium (symmetric & asymmetric), and 90 degree wide (symmetric). Elements: Clear quartz lamps. Coiled tungsten filament located within a sealed quartz envelope, halogen filled, with porcelain end caps and 6” wire pigtail leads. 96% radiant delivered efficiency with high moisture and thermal shock resistance. Instantaneous heat-up and cool-down performance. Available wattages from 500 to 3800 Watts per element. Available voltages from 120 to 600 Volts. Controls: Mul-T-Mount heaters are not manufactured with any control device on the unit. All controls are accessories and should be specified as such. Please consult the technical sales department of factory for help in determining applicable controls. Please follow installation instructions that accompany each heater. Accessories: Recessed mounting frames (painted or stainless steel), adjustable mounting brackets (stainless steel only), vertical mounting brackets (stainless steel only), wire guards, thermostats, snow detectors, SCR controllers, and power contactor panels. 90° Symmetric Watts Delivered per Square Foot 30º 3.2 5.5 x 60º 3.2 10.5 x 9.5 13 x 12 15 x 14 17 x 16 90º 3.2 17 x 16 21 x 20 N/R N/R 30º 5.0 6 7.5 x 5.5 8.5 x 6.5 9.5 x 7.5 10.5 x 8.5 11.5 x 9.5 12.5 x 10.5 208.3 121.2 90.5 70.2 56.0 45.8 38.1 60º 5.0 11.5 x 9.5 14 x 12 16 x 14 18 x 16 20.5 x 18.5 23 x 21 45.8 29.8 22.3 17.4 13.2 10.4 - 90º 5.0 18 x 16 22 x 20 26 x 24 17.4 11.4 8.0 - - - - 30º 7.3 N/R 8.5 x 5.5 9.5 x 6.5 10.5 x 7.5 11.5 x 8.5 12.5 x 9.5 13.5 x 10.5 156.1 118.2 92.7 74.7 61.5 51.5 60º 7.3 12 x 10.5 15 x 12 17 x 14 57.9 40.6 30.7 24.0 18.4 14.5 - 90º 7.3 19 x 16 23 x 20 27 x 24 N/R 24.0 15.9 11.3 - - - - 30º 4.8 5.5 x 6.5 x 6.5 7.5 x 7.5 8.5 x 8.5 9.5 x 9.5 10.5 x 10.5 11.5 x 11.5 174.5 113.6 85.3 66.4 53.2 43.5 36.3 60º 4.8 10.5 x 10.5 13 x 13 15 x 15 17 x 17 21 43.5 28.4 21.3 16.6 10.9 - - 90º 4.8 N/R 16.6 10.9 - - - - - 30º 7.5 153.8 117.6 92.9 75.2 62.1 52.2 60º 7.5 62.1 41.2 31.3 24.5 18.8 14.8 - 90º 7.5 24.5 16.2 11.5 - - - - 30º 10.95 60º 10.95 90º 10.95 19 x 17 3 - Quartz Lamp Heaters 2 - Quartz Lamp Heaters Heater Output (kW) Mounting Heights (FT.) 14 16 Reflective Pattern ( º ) # of Qtz. Lamps Sizing Chart 8 10 12 18 20 Mounting Heights (FT.) Heat Pattern Coverage @ Floor Level L x W 4 x 4 5 L x W L x W L x W 6.5 x 5.5 7.5 x 6.5 8.5 x 7.5 L x W L x W L x W 9.5 x 8.5 10.5 x 9.5 11.5 x 10.5 N/R N/R N/R N/R N/R 19 x 16 21.5 x 18.5 24 x 21 N/R x 21 N/R N/R N/R N/R 17 x 17 21 x 21 N/R N/R 7.5 x 6.5 8.5 x 7.5 9.5 x 8.5 10.5 x 9.5 11.5 x 10.5 12.5 x 11.5 11.5 x 10.5 14 x 13 16 x 15 18 x 17 20.5 x 19.5 23 x 22 N/R N/R N/R N/R N/R N/R N/R 18 x 17 22 x 21 26 x 25 N/R 8.5 x 6.5 9.5 x 7.5 10.5 x 8.5 11.5 x 9.5 12.5 x 10.5 13.5 x 11.5 12 x 11 15 x 13 17 x 15 23 x 21 27 x 25 19 x 17 21.5 x 19.5 24 x 22 N/R N/R N/R 8 10 12 14 16 18 20 145.5 89.5 65.6 50.2 39.6 32.1 26.5 32.1 20.5 15.2 11.8 - - - 11.8 7.6 - - - - - - - - 198.2 153.7 122.7 100.2 83.4 70.5 N/R 83.0 56.2 42.9 33.9 26.1 20.7 - N/R 33.9 22.7 16.2 - - - - 67 TH & THSS Series Mul-T-Mount Electric Infrared Heater 2 Lamp Mul-T-Mount Series Brown Enamel Or Stainless Steel With 2 Clear Quartz Lamps Included 68 BROWN HOUSING UPC 686334 STAINLESS STEEL HOUSING KW BTU’S VOLTS REFLECTOR PATTERN Replacement WT. Element (Lbs.) MODEL UPC 686334 MODEL 444163 222-30-TH-208V 444408 222-30-THSS-208V 208 444170 222-30-TH-240V 444415 222-30-THSS-240V 240 444187 222-30-TH-277V 444422 222-30-THSS-277V 277 481380 222-30-TH-480V 481434 222-30-THSS-480V 480 63016489 444194 222-A30-TH-208V 444439 222-A30-THSS-208V 208 63016209 444200 222-A30-TH-240V 444446 222-A30-THSS-240V 240 444217 222-A30-TH-277V 444453 222-A30-THSS-277V 277 481410 222-A30-TH-480V 481465 222-A30-THSS-480V 480 63016489 444224 222-60-TH-208V 444460 222-60-THSS-208V 208 63016209 444231 222-60-TH-240V 444477 222-60-THSS-240V 444248 222-60-TH-277V 444484 222-60-THSS-277V 481397 222-60-TH-480V 481441 222-60-THSS-480V 480 63016489 444255 222-A60-TH-208V 444491 222-A60-THSS-208V 208 63016209 444262 222-A60-TH-240V 444507 222-A60-THSS-240V 240 444279 222-A60-TH-277V 444514 222-A60-THSS-277V 277 481427 222-A60-TH-480V 481472 222-A60-THSS-480V 480 63016489 443296 222-90-TH-208V 444521 222-90-THSS-208V 208 63016209 444286 222-90-TH-240V 444538 222-90-THSS-240V 240 444293 222-90-TH-277V 444545 222-90-THSS-277V 277 481403 222-90-TH-480V 481458 222-90-THSS-480V 480 63016489 481083 342-30-TH-208V 480932 342-30-THSS-208V 208 63025209 481090 342-30-TH-240V 480949 342-30-THSS-240V 240 802611 342-30-TH-480V 802635 342-30-THSS-480V 480 63025489 481175 342-A30-TH-208V 481021 342-A30-THSS-208V 208 63025209 481182 342-A30-TH-240V 481038 342-A30-THSS-240V 240 444316 342-A30-TH-480V 444569 342-A30-THSS-480V 480 63025489 481113 342-60-TH-208V 480963 342-60-THSS-208V 208 63025209 3.2 5.0 10,922 17,065 240 277 30° Symmetrical 30° Asymmetrical 60° Symmetrical 60° Asymmetrical 90° Symmetrical 30° Symmetrical 30° Asymmetrical 63016279 63016249 63016279 63016249 63016279 63016279 63016249 63016279 63025249 63025249 342-60-TH-240V 480970 342-60-THSS-240V 342-60-TH-480V 802932 342-60-THSS-480V 480 63025489 481205 342-A60-TH-208V 481052 342-A60-THSS-208V 208 63025209 481212 342-A60-TH-240V 481069 342-A60-THSS-240V 240 444330 342-A60-TH-480V 444583 342-A60-THSS-480V 480 481144 342-90-TH-208V 480994 342-90-THSS-208V 208 481151 342-90-TH-240V 481007 342-90-THSS-240V 240 803212 342-90-TH-480V 803236 342-90-THSS-480V 480 802710 462-30-TH-480V 802734 462-30-THSS-480V 30° Symmetrical 63036489 444361 462-A30-TH-480V 444613 462-A30-THSS-480V 30° Asymmetrical 63036489 803014 462-60-TH-480V 803038 462-60-THSS-480V 60° Symmetrical 63036489 444385 462-A60-TH-480V 444637 462-A60-THSS-480V 60° Asymmetrical 63036489 803311 462-90-TH-480V 803335 462-90-THSS-480V 90° Symmetrical 63036489 480 60° Asymmetrical 20 63016249 481120 24,915 60° Symmetrical 63016249 802918 7.3 240 63016209 63025249 25 63025249 63025489 63025209 90° Symmetrical 63025249 63025489 NOTE: Consult the factory, the product instruction manual, or a licensed electrician for 3-phase wiring of all 2-element heaters. 32 THSS Series Mul-T-Mount Electric Infrared Heater 3 Lamp Mul-T-Mount Series Stainless Steel Housing With 3 Clear Quartz Lamps Included UPC# 686334 MODEL KW BTU’S VOLTS NOTE: Replacement Elements 443678 223-30-THSS-208V 208 443685 223-30-THSS-240V 240 443692 223-30-THSS-277V 277 481588 223-30-THSS-480V 480 63016489 443289 223-60-THSS-208V 208 63016209 443739 223-60-THSS-240V 240 443746 223-60-THSS-277V Manufactured in U.S.A. Reflector Pattern 69 4.8 16382 277 63016209 30° Symmetrical 60° Symmetrical 63016249 63016279 63016249 480 63016489 443784 223-90-THSS-208V 208 63016209 443791 223-90-THSS-240V 240 443807 223-90-THSS-277V 277 481601 223-90-THSS-480V 480 481236 343-30-THSS-208V 208 240 • 600-Volt Models also available, contact factory for more information. 811439 343-30-THSS-480V 480 481267 343-60-THSS-208V 208 • Asymmetrical pattern units are also available for 30° & 60° 811637 343-60-THSS-480V 480 481298 343-90-THSS-208V 208 481304 343-90-THSS-240V 240 811835 343-90-THSS-480V 480 481274 343-60-THSS-240V 7.5 25298 240 810531 463-30-THSS-480V 810739 463-60-THSS-480V 10.95 37372 810937 463-90-THSS-480V 480 90° Symmetrical 25 63016279 481595 223-60-THSS-480V 481243 343-30-THSS-240V WT. (Lbs.) 63016249 63016279 63016489 30° Symmetrical 60° Symmetrical 90° Symmetrical 63025209 63025249 63025489 63025209 63025249 33 63025489 63025209 63025249 63025489 30° Sym. 63036489 60° Sym. 63036489 90° Sym. 63036489 41 TH & THSS Series Product Accessories UPC 686334 881128 851152 851145 851626 854368 854351 854344 MODEL DESCRIPTION FOR USE WITH VMB-41-SS CHWG-222 CHWG-342 CHWG-462 CHWG-223 CHWG-343 CHWG-463 Wall Mounting Brackets (2) All Mul-T-Mount Models 441995 449441 442077 441872 442107 449458 881104 881135 881111 440783 440738 440745 446150 446167 446228 RMF-222-SS-A RMF-222-A RMF-342-SS-A RMF-342-A RMF-462-SS-A RMF-462-A RMF-223-SS RMF-343-SS RMF-463-SS 31939009 31940009 31941009 632-1620 632-1624 632-2548 Stainless Steel Wire Guards Recessed Mounting Frames (UL) Ceiling Cutout (in.) Frame Size (in.) 27 x 17-7/8 29-1/8 x 20 27 x 17-7/8 29-1/8 x 20 36 x 17-7/8 38-1/8 x 20 36 x 17-7/8 38-1/8 x 20 49 x 17-7/8 51-1/8 x 20 49 x 17-7/8 51-1/8 x 20 32 x 29-3/8 34-1/8 x 31-1/2 41 x 29-3/8 43-1/8 x 31-1/2 54 x 29-3/8 56-1/8 x 31-1/2 Red Vycor Sleeves Reduces Quartz Lamp Brightness by 90% Red Quartz Lamps; 1.6kw, 208v Red Quartz Lamps; 1.6kw, 240v Red Quartz Lamps; 2.5kw, 480v 222 Series 342 Series 462 Series 223 Series 343 Series 463 Series 222 Series Stainless 222 Series Painted 342 Series Stainless 342 Series Painted 462 Series Stainless 462 Series Painted 223 Series Stainless 343 Series Stainless 463 Series Stainless All 1600W Qtz. Lamp All 2500W Qtz. Lamp All 3650W Qtz. Lamp 222,223 & RPH Series 342 & 343 Series WT. (LBS.) 12 2 6 9 11 15 18 20 2 2 OCH Series Outdoor / Indoor Rated Quartz Electric Infrared Heater Features 70 Heats solid objects, not the air! Manufactured in U.S.A. • Frosted Quartz Tube heating element (included) • Listed for suspended, totally exposed (outdoor) and indoor spot heating applications • Finish: High-temp brown powder coated finish or corrosion resistant stainless steel 24 gauge housing • 60° Symmetric Heat Pattern • Gold anodized Aluminum reflector and end caps • Painted models are direct wire, unless specified and are supplied with 6” lead wires for field connection in the internal wiring compartment. These models are available with a factory installed 6’ cord set. The 208V model must have a field supplied plug. • Stainless steel models include an electrical enclosure assembled to the end of the heater housing and (2) 6” long lead wires for direct field connection. • Two 2’ ft. long mounting chains and four S-Hooks included • The OCH-Series can be surfaced mounted using the supplied mounting brackets which allow up to a 45° horizontal tilt adjustment. Product Models FINISH - BROWN FINISH - STAINLESS STEEL CONNECTION WATTS BTU’S VOLTS AMPS TYPE Includes Electrical Enclosure Qtz. Tube WT. Repl. (LBS.) Element UPC# 686334 MODEL UPC# 686334 MODEL 480444 OCH-46-120VE 480529 OCH-46-120V-SSE 1500 5120 120 12.5 671-3784 480451 OCH-46-208VE 480536 OCH-46-208V-SSE 2000 6826 208 9.6 671-5061 480468 OCH-46-240VE 480543 OCH-46-240V-SSE 2000 6826 240 8.3 671-3785 480475 OCH-46-277VE 480550 OCH-46-277V-SSE 2000 6826 277 7.2 671-5018 480499 OCH-57-208VE 480574 OCH-57-208V-SSE 3000 10239 208 14.4 671-5060 480482 OCH-57-240VE 480567 OCH-57-240V-SSE 3000 10239 240 12.5 671-3786 480505 OCH-57-277VE 480581 OCH-57-277V-SSE 3000 10239 277 10.8 671-5059 480512 OCH-57-480VE 480598 OCH-57-480V-SSE 2250 7679 480 4.7 485975 OCH-46-120VCE --- --- 1500 5120 120 12.5 671-3784 485982 OCH-57-208VCE --- --- 2000 6826 208 9.6 671-5061 485999 OCH-57-240VCE --- --- 2000 6826 240 8.3 671-3785 Hard Wire Corded 10 12 671-5058 11 13 Product Accessories UPC# 686334 MODEL 480888 OCHWG-46 DESCRIPTION FOR USE WITH WT. (LBS.) OCH-46 Series Models 2 OCH-57 Series Models 2 Stainless Steel Wire Guards 480895 OCHWG-57 881128 VMB-41-SS Wall Mtg. Brackets (2) ALL OCH Models 12 445948 VHC-15 Variable Heat Controller ALL OCH Models 3 485357 VHC-32 Variable Heat Controller ALL OCH Models 3 OCH Series Outdoor / Indoor Rated Quartz Electric Infrared Heater OCH Sizing Chart Mounting Height 7’ 8’ 9’ 10’ 12’ Heater Model Watts OCH-46 OCH-46 OCH-46 OCH-46 OCH-57 OCH-57 OCH-46 OCH-46 OCH-57 OCH-57 OCH-57 OCH-57 OCH-57 OCH-57 1500 2000 1500 2000 3000 2250 1500 2000 3000 2250 3000 2250 3000 2250 Heat Pattern Coverage ( at floor level) Length Width Sq. Ft. 11 9 99 11 9 99 12 10 120 12 10 120 13 10 130 13 10 130 13 11 143 13 11 143 14 11 154 14 11 154 15 12 180 15 12 180 17 14 238 17 14 238 Total Watts / Sq. Ft. 15.2 20.2 12.5 16.7 23.1 17.3 10.5 14.0 19.5 14.6 16.7 12.5 12.6 9.5 Product Specifications Series: OCH-46 & OCH-57 Housing: 24 gauge Aluminized Steel with a baked on brown powder coat finish. Housing is cETLus Listed for indoor or outdoor applications. Horizontal mounting only. Reflectors and End Caps: .040 Gold anodized Aluminum reflectors and end caps for superior reflectiveness. 60 degree medium (symmetric) pattern only. Elements: Quartz Tubes. Frosted quartz envelope with a Nickel-Chromium coiled filament, porcelain end caps, and threaded-screw (stud) terminations. Fast heat-up and cool-down performance. Available Wattages from 1500 to 3000 Watts per element. Available voltages from 120 to 480 Volts. Controls: OCH Series heaters are not manufactured with any control device on the unit. All controls are accessories and should be specified as such. Please consult the technical sales department of factory for help in determining applicable controls. Please follow installation instructions that accompany each heater. Accessories: Adjustable mounting brackets (stainless steel only), vertical mounting brackets (stainless steel only), wire guards, thermostats, SCR controllers, and power contactor panels. Mounting Configurations & Reflector Pattern Mounting • Chain, surface mount or use our vertical mounting bracket as shown below. (Note:) All units must be mounted horizontally. • In-Built surface mounting bracket allows for fixture adjustment up to a 45° horizontal tilt. • As shown, the heater may be suspended at any horizontal angle desired. Chain Mount: (Chain supplied) Reflector Pattern: OCH-46 Length: 44.4’’ Width: 5.4’’ Height: 6.5’’ OCH-57 Length: 55.4’’ Width: 5.4’’ Height: 6.5’’ Optional Vertical Mounting Bracket: Model # VMB-41-SS Mounting Clearances & Recommended Mounting Height Mounting Clearances 3” from ceiling; 12” from vertical surface 72” from face of heater to combustible surface 36” from another heater Recommended Mounting Height OCH-46 7’-9’ OCH-57 8’-10’ 71 RPH Series Outdoor Rated Stainless Steel Electric Infrared Heater • Instant, high-intensity radiant heat, with 30° symmetric heat pattern. • Listed for indoor spot heating and for outdoor unprotected applications. • Specialized Ruby “Red” Quartz Lamp infrared heating element for glare reduction. • Stainless Steel housing with Coilzak Aluminum reflector for good reflectivity & corrosion resistance. • Heating element and mounting plate included. Manufactured in U.S.A. • Dimensions: 24” x 5-3/8” x 4-1/2.” 72 Mounting Clearances Recommended Mounting Height 6” from ceiling 24” from vertical surface 72” from face of heater to combustible surface Mounting Plate (provided) on top center allows heater to be mounted parallel or angled using a standard pipe nipple and box cover (supplied by installer) UPC# 686334 MODEL 884501 884518 RPH-208-A RPH-240-A WATTS BTU’S VOLTS PHASE AMPS 1600 1600 5,461 5,461 208 240 1 1 RPH-208 8’-12’ RPH-240 8’-12’ Optional Wireguard REPLACEMENT WT. QUARTZ LAMP (LBS.) UPC# 686334 MODEL 7.7 6.7 632-1620 632-1624 5 5 880992 RPHWG MM Series “Mitey Midget” Electric Infrared Heater • Instant, high-intensity radiant heat, with 60° symmetric heat pattern. • MM heaters excel as people-heaters in areas requiring a linear, compact & concentrated heat source. • Listed for indoor industrial and commercial comfort heat applications. • Heavy duty Aluminum extrusion with a bright Aluminum insert for maximum reflectivity. Mounting Clearances • Anodized Aluminum housing, (0.62” thick). 24” from ceiling & from vertical surface • Heat Element Sold Separately. 24” from face of heater to combustible surface 36” from another heater Manufactured in U.S.A. • Dimensions: 3.750” Wide x 3.380” High. UPC 686334 MAX WATTS MODEL MAX BTU'S VOLTS UNIT LENGTH PH Optional Wireguards UPC MODEL 686334 443906 MMWG-13 WT. (LBS.) 444019 MM-13A 500 1707 120 1 13" 3 442763 MM-18A 750 / 1000 3413 208-240 1 18" 4 443913 MMWG-18 449540 MM-24A 900 / 1600 5461 208-277 1 24" 5 441896 MMWG-24 442725 MM-33A 2500 8533 480 1 33" 6 443920 MMWG-33 442039 MM-46A 3000 / 3800 12457 480-600 1 46" 7 442046 MMWG-46 All MM-13A through MM-46A models are ETL Listed for use with Quartz Lamps Only! FFH Series Electric Utility Infrared Heater • Both FFH Series Heaters are excellent for Farrowing & Finishing applications. • Both units feature an 8 ft. 18/3 grounded cordset to plug into any 120V service. • Gold anodized Aluminum reflectors, with a 90° symmetrical reflector pattern. • Compact housing design, with the following housing finish: FFH-512A: Gold Anodized Finish FFH-912B: Brown Enamel Finish FFH-512A • Quartz Tubes Heat Element(s), Wire Guard & (2) 4’ ft. Jack Chains are included. • FFH-912B Only: Offers (2) On/Off SIZING CHART - FFH SERIES toggle switches to operate heating MOUNTING Heater LENGTH WIDTH COVERAGE WATTS HEIGHT Model (Sq. Ft.) / Sq. Ft. elements independently. FFH-512A 7 6 42 13.1 6’ FFH-912B • Listed for indoor industrial and FFH-912B 6 7 42 21.4 FFH-512A 8 7 56 9.8 commercial comfort heat 7’ FFH-912B 7 8 56 16.1 FFH-512A 9 8 72 7.6 Manufactured in U.S.A. 8’ FFH-912B 8 Dimensions (in.) REPLACEMENT WT. UPC# MODEL WATTS BTU’S VOLTS PHASE AMPS 686334 QUARTZ TUBE (LBS.) Length Width Height 883894 FFH-512A 550 882781 FFH-912B 450/900 1877 3072 120 120 1 1 5 8 671-3492 671-3454 4 4 22 17 5 6 3 4 9 72 12.5 Mounting Clearances 3” from ceiling 24” from vertical surface 72” from floor Electric Infrared Heating Elements Clear & Red Quartz Lamps Notes: Life expectancy of all heating elements - 5,000 hours (4yr. Pro-rated Warranty). All heating elements operate at 50 / 60 Hertz. • Length (in.) Length (in.) UPC Fits UPC Fits Item # Watts Volts Item # Watts Volts 686334 Model 686334 Model Overall Heated Overall Heated 440059 630-05129 500 120 8-11/16 5 MM-13A 440363 631-25489 342, 343 or 480 2500 28-11/16 25 440684 631-25609 600 MM-33A 442770 630-10209 208 1000 13-11/16 10 MM-18A 444118 630-10249 240 ------------------------440165 630-16209 208 462, 463 or 440172 630-16249 240 38 440677 630-36489 3650 480 41-11/16 MM-46A 222, 223 or 440998 631-16249 1600 240 446235 630-38579 3800 600 19-11/16 16 MM-24A 444132 631-38579 3800 600 440189 630-16279 277 481731 630-16489 480 RED QUARTZ LAMPS 481748 630-25209 208 481755 630-25249 240 342, 343 or 446150 632-1620 1600 208 19-11/16 16 222/223 2500 28-11/16 25 632-1624 1600 240 19-11/16 16 or RPH MM-33A 446167 481762 630-25279 277 440547 630-25489 480 446228 632-2548 2500 480 28-11/16 25 342 or 343 Model Suffix: 630 = Horizontal Burning “Clear”; 631 = Vertical OR Horizontal Burning “Clear”; = Horizontal Burning “Red” Color temperature emitted: approx. 4100° F (high brightness). Approximately 96% radiant efficiency. Excellent resistance to thermal shock. • • • • 3/8” Diameter clear or red quartz envelope. Coiled tungsten filament; sealed porcelain end caps; halogen gas filled. Quartz Tubes Notes: Life expectancy of all heating elements - 5,000 hours. All heating elements operate at 50 / 60 Hertz. UPC 686334 443234 441810 441803 441933 441667 441476 441940 441957 440356 440080 446242 446259 *3/8” Diameter Item # Watts Volts 671-3784 671-5061 671-3785 671-5018 671-5060 671-3786 671-5059 671-5058 671-3454 671-3492* 671-5056 671-5057 1500 2000 2000 2000 3000 3000 3000 2250 450 550 1000 1425 120 208 240 277 208 240 277 480 120 120 120 240 Length (in.) Overall Heated 39-11/16 34-3/16 39-11/16 34-3/16 39-11/16 34-3/16 39-11/16 34-3/16 50-11/16 45-3/16 50-11/16 45-3/16 50-11/16 45-3/16 50-11/16 45-3/16 12-15/16 8-7/16 19-1/2 16 18-5/16 14-7/16 27-5/16 23-7/16 Fits Model OCH-46 OCH-57 FFH-912B FFH-512A CH-2212-1C CH-6424-1C • 5/8” Diameter frosted quartz envelope • Nickel-Chromium alloy coiled element with porcelain end caps and pigtailed termination • Color temperature emitted: approx. 1800° F (bright orange glow) • Approximately 60% radiant efficiency • Fast heat-up/cool-down • Moisture resistance: High • Mechanical ruggedness: Good Metal Sheath Elements Notes: Life expectancy of all heating elements - 5,000 hours. All heating elements operate at 50 / 60 Hertz. UPC# 686334 445870 445832 445795 445849 445801 445887 445856 445818 445863 446174 445894 UPC# 686334 445788 445702 445719 445726 445733 445771 445597 445603 445610 445627 445665 MODEL WATTS VOLTS 641-37211 641-35661 641-35611 641-36051 641-35621 641-50011 641-36061 641-35631 641-36071 641-35641 641-50021 1800 2000 4500 120 208 240 277 480 600 208 240 277 480 600 LENGTH (in) Overall Heated 23-1/16 18 44-7/16 39 MODEL WATTS VOLTS 641-70321 641-70241 641-70251 641-70261 641-70271 641-70281 641-70001 641-70011 641-70021 641-70031 641-70041 1800 120 208 240 277 480 600 208 240 277 480 600 2000 4500 Replacement Heating Element Fits “CH-Models” Fits “FHK Models” CH-212-1A FHK-212-1CA CH-220-1A, CH-620-3A CH-224-1A, CH-624-3A FHK 2.0 & 6.0 KW CH-277-1A, CH-627-3A Models CH-248-1A, CH-648-3A CH-257-1A, CH-657-3A CH-420-1A, CH-1320-3A, CH-2720-3B CH-424-1A, CH-1324-3A, CH-2724-3B FHK 4.5 & 13.5 KW CH-427-1A, CH-1327-3A Models CH-448-1A, CH-1348-3A, CH-2748-3B CH-457-1A, CH-1357-3A, CH-2757-3B LENGTH (in) Overall Heated 24-1/16 18 45-7/16 39 Note: Inner reflector shipped with replacement Metal Sheath Elements. Replacement Heating Element Fits “CH-Models” Only CH-212-1C CH-220-1C, CH-620-3C CH-224-1C, CH624-3C CH-227-1C, CH-627-3C CH-248-1C, CH-648-3C CH-257-1C, CH-657-3C CH-420-1C, CH-1320-3B, CH-2720-3C CH-424-1C, CH-1320-3B, CH-2720-3C CH-427-1C, CH-1327-3B CH-448-1C, CH-1348-3B, CH-2748-3C CH-457-1C, CH-1357-3B, CH-2757-3C • 0.430” Diameter Incoloy metal sheath envelope • NickelChromium alloy coiled element imbedded in Magnesium Oxide insulating powder • Color temperature emitted: approx. 1600° F (dull orange glow) • Approximately 50% radiant efficiency • Slowest heat-up/ cool-down • Moisture resistance: Lowest • Mechanical ruggedness: Highest 73 Electric Infrared Heating Controls Variable Controllers 74 30-Amp or 80-Amp Enclosed VHC-32 • • • • • • Manufactured in U.S.A. VHC-15 Solid State phase angle variable “Triac” knob controller adjusts heat settings from 10-100% with heat loads up to 15.4-Amps. 208/240 VAC single-phase, single stage controller, 3200 Watt max. Positive “Off” & built-in On/Off Rocker switch lights “red” during operation. NEMA 1 Aluminum enclosure with stainless steel face plate designed for wall mounting or suitable for semi-recessed applications. Must be mounted in a protected area. Can either operate Quartz Lamps or Quartz Tube Infrared Heaters. UPC 686334 485357 445948 445634 445641 445658 Manufactured in U.S.A. • • • • • • Solid state variable device controls heat loads up to 15-Amps. 208/240Volt “In-Line” Controller. Built in On/Off knob switch with positive “off” & surface plate included. Designed for a 2” x 4” electrical wall box mounting (not supplied). Must be mounted in a protected area. Can only operate Fostoria Quartz Tube Infrared Heaters. 18D-2-80CF ENC. Manufactured in U.S.A. • • • • • SCR Voltage Controller - 80 Amp MAX. Includes (1) 24-volt Potentiometer (3” square) to control the heat output. Only operates Quartz Lamps at 240 or 208-Volts, single phase only. Potentiometer can be mounted outside, but the SCR must be located in a protected area. Factory wired with millisecond fuses included. Model Description VHC-32 VHC-15 18D-2-30CF (Open) 18D-2-30CF (Enclosed) 18D-2-80CF (Enclosed) Variable Heat Controller 208/240-Volt; 15.4 Amp Variable Heat Controller; 208/240-Volt; 15 Amp SCR Controller - 26 Amp MAX; No Enclosure SCR Controller - 26 Amp MAX; Enclosure Included SCR Controller - 80 Amp MAX; Enclosure Included Dimension (In.) Depth Width Height 3 5 5 3 5 5 6 6 9 8 10 12 8 12 14 Wt. 3 lbs. 3 lbs. 11 lbs. 15 lbs. 29 lbs. Snow & Ice Detectors • Main control unit for Automatic Snow & Ice Control Systems. By sensing both temperature and moisture the system activates and melts any snow & ice accumulations until conditions subside. • NEMA 3R Enclosure is UL Listed and houses timers and switching electronics to operate the system. • Capability to monitor up to 6 sensors (CIT-1). • Unit can be manually activated and can be controlled and monitored from an optional remote switch (Model RCU-). Positioned above ground to maximize the sensors capability. Detects falling or blowing of precipitation such as snow when the temperature is below 38° F. Most common sensor device. • CIT-1 APS-3C • Manufactured in U.S.A. • • UPC# 686334 Model 319614 APS-3C Snow / Ice Control Switch 319761 CIT-1 General Purpose Snow Sensor Dimension (In.) Description Depth Wt. Width Height 6.56 11.5 9.25 8 lbs. 3.25 3.25 4.13 1 lb. Note: Any snow & ice control system should be used with the correct sized control panel (with contactors & fusing) as supplied by factory or your electrical contractor. Also, the APS-3C requires a control device (RCU-1, CIT-1, SIT-6E) in order to operate properly. Contactor Enclosures • • • • FEC-30-120 Manufactured in U.S.A. Economical load handling / switch device, ideal for use with other control equipment. NEMA 1 Enclosures. Load rating up to 600V Max., 3-Pole. Magnetic contactor. UPC 686334 440851 440868 440875 440882 Model FEC-30-120 FEC-30-240 FEC-60-120 FEC-60-240 Contactor Amps 30 60 Coil Voltage 120 208/240 120 208/240 Depth 5 Cabinet Size (In.) Width Height 6 Note: Installer to provide overload protection for all infrared heaters. 10 Wt. (LBS.) 5 Electric Infrared Heating Controls Pre-Wired Contactor Panels • Factory pre-wired for quick installation, with the following optional equipment: Snow & Ice Detector (APS-3C) Single & Two-Stage Thermostats Two-stage thermostats require a minimum 2-contactors. • Step-down transformer and secondary fusing for 24V or 120V control circuit. • 3-Phase load rated. • Fuses are NOT included. • NEMA 1 Enclosures. • Max 50-Amp branch circuit fusing. Note: Contact factory for 3R, 4, 4X, & NEMA 12 “special” built models. IMPORTANT FUSING INFORMATION FPC2120 Fuses are NOT included since panels can be used with various infrared heat sources. Quartz Lamp Heat Sources: Use FRS-600V (or equal) “Time Delay” fuses; Class RK-5. Quartz Tube & metal Sheath Heat Sources: Use KTS-R 600V (or equal) “Fast Acting” fuses; Class RK-1. Fuse circuits as close to calculated load as possible. Circuits less than 35 Amps will require the use of fuse reducers. Manufactured in U.S.A. Standard Models 120-V CONTROL SYSTEM 24-V CONTROL SYSTEM CABINET SIZE (IN.) MAX AMPS UPC# 686334 MODEL UPC# 686334 MODEL 4459902 FPC8110 4864302 FPC8210 4460002 FPC2110 4864402 FPC2210 WT. (LBS.) VOLTS DEPTH WIDTH HEIGHT 208 240 50 4460102 FPC7110 4864502 FPC7210 277/480 4460202 FPC4110 4864602 FPC4210 480 4460302 FPC8120 4864702 FPC8220 208 4460402 FPC2120 4864802 FPC2220 6.75 16 24 52 6.75 16 24 70 6.75 24 30 88 6.75 30 36 106 240 100 4460502 FPC7120 4864902 FPC7220 277/480 4460602 FPC4120 4865002 FPC4220 480 4460702 FPC8140 4865102 FPC8240 208 4460802 FPC2140 4865202 FPC2240 240 4460902 FPC7140 4865302 FPC7240 277/480 4461002 FPC4140 4865402 FPC4240 480 4461102 FPC8160 4865502 FPC8260 208 4461202 FPC2160 4865602 FPC2260 200 240 300 4461302 FPC7160 4865702 FPC7260 277/480 4461402 FPC4160 4865802 FPC4260 480 75 FHK Series Portable Metal Sheath Electric Infrared Heater • Double side wall housings to reduce operating temperatures. • 6.0 and 13.5KW heaters have double top baffles to reduce operating temperatures. • 60° symmetrical heat pattern. • Factory installed U-shaped metal sheath infrared heating elements have an average 5000 hour life. • Heavy duty protective wire screens. • GOLD anodized Aluminum internal reflector. • Ground fault protection must be used. 76 Square Feet Heated NON-PROTECTED AREA BELOW ABOVE 35 oF 35 oF KW 2.0KW & 4.5KW Stand Models Required Clearance From Front of Heater 1.8 / 2.0 25 36 40 50 2 feet 4.5 64 75 90 125 3 feet 6 85 100 120 150 4 feet 13.5 192 225 270 375 7 feet 6.0KW & 13.5KW Hand Cart Models Manufactured in U.S.A. SEMI-PROTECTED AREA BELOW ABOVE 35 oF 35 oF Standard FHK Models UPC# 686334 MODEL 881739 FHK-224-1A 881753 FHK-248-1A 881784 FHK-424-1A 881807 FHK-448-1A 882910 FHK-624-3A KW BTU's 2.0 6,826 4.5 15,359 VOLTS PH AMPS 240 1 8.3 480 1 4.2 240 1 18.8 480 1 9.4 3 14.4 1 25.0 3 7.5 1 240 6.0 20,478 882934 FHK-648-3A 480 882965 FHK-1324-3A 240 882989 FHK-1348-3A 13.5 46,076 480 OPTIONAL 25' POWER CORD WT. UPC# 686334 MODEL 880435 SO 16/3 880435 SO 16/3 880459 SO 12/3 880466 SO 14/3 880497 SO 14/4 880442 SO 10/3 880497 SO 14/4 13 880466 SO 14/3 3 33.0 880510 SO 8/4 3 17.0 316422 SO 12/4 1 29.0 880527 SO 8/3 17 lbs. 24 lbs. 37 lbs. 65 lbs. Contact Factory for Special Build Models @ 208V, 277V or 600V. Factory Pre-Wired FHK Models With 15 Ft. Cord & Grounded Plug UPC# 686334 MODEL TYPE KW BTU's VOLTS PHASE AMPS WT. 881715 FHK-212-1CA STAND 1.8 6,143 120 1 15.0 18 lbs. 882798 FHK-624-1CA CART 6.0 20,478 240 1 25.0 40 lbs. FHK Infrared Control Options Dimensions (In) Ht. Wd. Dp. WT. Model “TO” & “GF” features (lbs.) include a positive “off” & a UPC MODEL # 686334 DESCRIPTION Operating Voltage (VAC) 485814 TO-SK-1 Tip-Over Switch 208V - 600V 10.3 10.3 5.0 12 589376 DC-SK-1 Disconnect Switch 120V - 600V 5.0 6.0 4.0 5 208V - 600V 10.3 10.3 5.0 12 486026 GF-SK-1 Ground Fault Sensing Switch Note: All SK-1 Models have NEMA-1 Enclosure, 50-Amp Max. & 1/3-Phase Rated. built-in on/off rocker switch that glows red during operation. Additionally, enclosure can mount directly to the terminal box on the back of the heater (FHK-6/13 only) or be mounted to a remote wall surface. TO-SK-1 or GF-SK-1 CH Series Portable Quarts Infrared Heater MODEL CH 2212-1C has two 1000 Watt elements that can be switched on / off by toggle switches to produce 1000 Watts or 2000 Watts of heat. - 15’ cord and NEMA 5-20 molded plug. MODEL CH 6424-1C has two sets of 1425 Watt elements that can be switched on / off by toggle switches to produce 2850 Watts or 5700 Watts of heat. - 15’ cord and NEMA L6-30 twist lock plug. • 60° symmetrical heat pattern. • Quartz tubes and built in wire guards included. • Interior or protected outdoor use only. • GOLD anodized Aluminum reflector and end caps. Chain mounted CH 2212-1C UPC 686334 MODEL 884099 CH-2212-1C 884105 CH-6424-1C 852401 FHK-1 KW 2.0 / 1.0 5.7 / 2.85 BTU's VOLTS PHASE 6826 / 3413 120 1 19454 / 9727 240 1 OPTIONAL CART 20 AMP Plug NEMA #5-20 PCH Series Portable Quartz Infrared Spot Heater Listed for overhead operation Note: CH-6424-1C operates with a 30- Amp twist lock plug. Manufactured in U.S.A. 20 AMP Plug NEMA #6-20P Portable Infrared Instant On-Off Heat Gun Features Features • Suitable for portable spot heat or for curing clear coat paint Width: 53” • Height adjustable from 2’ to 4’ Height: 2-6’ • On-Off rocker switch standard Depth: 28” • 4 casters included; Tip-Over power cutoff safety switch • 60o symmetrical heat pattern • 5/8” diameter quartz tube included • Average element life is 5000 hours • Bright Aluminum reflector and end caps • 20 gauge powder coated Steel housing • 15’ long, 3 wire (14/3) cordset with standard 3 pring NEMA 5-20P UPC# 686334 884112 WT. 16 lbs. 31 lbs. 20 lbs. 30 AMP Plug NEMA #6-30P Note: CH-2212-1C operates with a 20- Amp molded plug. Portable Cart Unit CH 6424-1C with FHK-1 Cart AMPS 16.7 / 8.35 23.8 / 11.9 • • • • • Provides instant spot heat in a controlled pattern Spot cure retouched paint and other finishes De-wrinkle or relax materials such as cloth-vinyl-leather T-3 Tungsten IR lamp Spring loaded power button switch • 10’ long, 18/3 grd. cordset with NEMA plug UPC# 686334 MODEL MODEL WATTS BTU’s VOLTS PHASE WT. 592284 RHG-1012A PCH-48C 1500 5120 120 1 30 592277 RHG-1012B WATTS VOLTS AMPS WT. 1000 120 8.4 3 Portable Electric Infrared Heat Panels Features • Portable panels are built to withstand rigors of industrial and heavy-commercial applications, such as auto collision repair shops. • 20 gauge Steel frame, base, and housing construction. • 3” Steel casters for high stability and ease of mobility • Gold anodized Aluminum reflectors and end caps allow 10% faster cure time than polished Aluminum reflectors, especially in paint and dust-laden atmospheres. • Elements achieve full temperature in less than 2 minutes • Fused disconnect switches are installed on the back of each unit. • Units are positioned with adjustable hinges allowing the user to use direct heat more precisely to the target area. • Gentle but effective medium-wave radiant heat can quickly boost, flash-off, or cure a variety of finishes, and lessens the chance of blistering and/or overheating the coating. • Medium-wave infrared heating elements are also effective for flash-off of water-based clear coatings being mandated by environmental agencies in many states. HP-5-QT HP-11-QT General Curing Guidelines Solvent Based Water Based Two Component Water Based Acrylic enamel & Urethane Clear Coat & Primer Primer Primer Clear Coat Polyurethane Clear Coat High Solids Top Coat Curing Time 3-5 mins 3-6 mins 8-20 mins 3-10 mins 12-30 mins 10-30 mins Note: Curing times will vary depending on material and shop conditions. This chart is based on distances of 18-24” away from the target area. Material Type Standard Models UPC# 686334 884129 884136 884143 Model HP-5-QT HP-6-QT HP-11-QT WATTS VOLTS AMPS 4,800 6,400 11,200 240 20 26.7 46.7 HEAT CABLE SOURCES TYPE (20’) 4 12-3 SO 4 7 6-3 SO Dimension (In.) Width Height 44-5/8 56-1/2 66-5/8 89-1/2 Heated Area (In.) Width Height 40 44 61 77 Wt. 116 141 225 77 FES & YES Series Heat WaveTM Portable Electric & Wall or Ceiling Mounted Salamander FES Series Product Features & Information 78 AVERAGE MINUTES TO ACHIEVE TEMPERATURE RISE* BUILDING SIZE: 1000 SQ. FEET 1500 SQ. FEET 2000 SQ. FEET TEMP RISE TEMP RISE TEMP RISE HEATER: 20 oF 40 oF 20 oF 40 oF 20 oF 40 oF 10 KW 70 min 140 min 105 min 210 min ----15 KW 47 min 94 min 71 min 142 min 94 min 188 min 23 min 46 min 35 min 70 min 47 min 94 min 30 KW 45 KW 10 min 30 min 20 min 35 min 35 min 40 min * Based on a 15' ceiling height - lower ceiling height will reduce time required • Safety yellow heater enclosure with safety screens on both air intake and output openings. • Optional 25’ long SO type cord, ready for plug attachment is available for each model. • Long-life finned tubular heating elements. THE ELECTRIC • Thermostat adjustment 40° to 100° F. ALTERNATIVE TO • Magnetic contactor. PROPANE AND • Automatic reset. KEROSENE SPACE • High-limit thermal cutout switch. • Fan only switch. HEATERS • 10” wheels. • 800 CFM-15KW units - 1100 CFM-30KW units. Manufactured in U.S.A. Standard FES Models UPC# 686334 886017 886079 886024 886031 886048 886055 886062 MODEL KW BTU's VOLTS PH AMPS TEMP RISE WT. FES-1520-3A FES-1524-1A FES-1524-3E FES-1548-3E FES-1560-3A FES-3048-3A FES-3060-3A 15 15 15 15 15 30 30 51195 51195 51195 51195 51195 102390 102390 208 240 240 480 600 480 600 3 1 3 3 3 3 3 42 63 36 18 15 36 29 45oF 45oF 45oF 45oF 45oF 90oF 45oF 65 lbs. 69 lbs. 65 lbs. 65 lbs. 65 lbs. 83 lbs. 65 lbs. 10 KW, 240V, 1Phase factory pre-wired model with 10 ft. cable & straight blade range plug. OPTIONAL 25' POWER CORD* UPC 686334 MODEL 316408 SO 6/4 880530 SO 4/3 316408 SO 6/4 316422 SO 12/4 316408 SO 6/4 316422 SO 12/4 *Plug not included. UPC# 686334 MODEL KW BTU's VOLTS PHASE AMPS TEMP RISE WT. 874434 FES-0924-1C 9 30717 240 1 38 25oF 55 lbs. 886000 FES-1024-1CA 10 34130 240 1 42 30oF 60 lbs. 45 Kilowatt FES Model • OPTIONAL 25’ POWER CORD UPC# 686334 MODEL 316439 SO 4/4 316408 SO 6/4 UPC 686334 MODEL 872225 FES-4548-3 45 153585 480 3 487405 FES-4560-3 45 153585 600 3 KW BTU’s VOLTS PH Safety yellow heater enclosure with safety screens on both air intake and output openings. • Optional 25’ long SO type cord, ready for plug attachment is available for each model. • Long-life finned tubular heating elements. • Thermostat adjustment 40° to 100° F. • Two 10” rear wheels and a front locking caster. • High-limit thermal cutout switch with TEMP manual reset. AMPS WT. RISE • 2200 CFM 54.2 70°F 125 lbs. • Fan only operation feature 44 70oF 125 lbs. Standard YES Models Manufactured in U.S.A. • Wall / ceiling mount included with unit • Unit is ready for direct wiring • Thermostat adjustment 40° to 100° F. UPC MODEL KW 686334 886086 YES-1520-3A 15 886185 YES-1524-1A 15 886093 YES-1524-3E 15 886109 YES-1548-3E 15 886123 YES-3048-3A 30 BTU's 51195 51195 51195 51195 102390 VOLTS PHASE AMPS TEMP RISE 208 240 240 480 480 3 1 3 3 3 42 63 36 18 36 45oF 45oF 45oF 45oF 90oF WT. 60 lbs. 60 lbs. 60 lbs. 60 lbs. 72 lbs. Wall Mounted Ceiling Mounted 198 Series 120 Volt Radiant and/or Fan Forced Portable Heater • 3-Heat settings: • - 600 Watt radiant - 900 Watt fan forced - 1500 Watt radiant & fan forced • Temperature control thermostat • • Dual safety system: - Tip over switch - Manual reset type limit control 6’ long - 3 conductor cord 1 year limited warranty 79 Width: 11” Height: 15” Depth: 12” Standard Models UPC 686334 445092 MAX VOLTS BTU's MODEL WATTS 198 TMC 1500 / 900 / 600 5120 120 AMPS PHASE WT. 12.5 / 7.5 / 5 1 9 lbs. 178 Series 120 Volt Ceramic Fan Forced Portable Heater • 850W & 1500W heat settings • plus fan only setting Temperature control thermostat 6’ long - 3 conductor cord • • Double safety system: - Automatic reset type limit control - Thermal cut-off device Width: 11-1/4” Height: 10” Depth: 7” Standard Models UPC MODEL WATTS MAX BTU's VOLTS AMPS PHASE 686334 445931 178 TMC 1500 / 950 5120 120 12.5 / 7.1 1 Note: Photograph is a representation of stocked models. Actual model may vary in appearance. WT. 8 lbs. 188 Series 120 Volt “Milk-house” Style Fan Forced Portable Heater • • • 1300W & 1500W heat settings • plus fan only setting Temperature control thermostat 6’ long - 3 conductor cord Width: 10” Height: 16” Depth: 9-1/2” Triple safety system: - Tip over switch - Automatic reset type limit control - Thermal cut-off device Standard Models UPC 686334 MODEL WATTS MAX BTU's VOLTS AMPS PHASE WT. 800419 188 TASA 1500 / 1300 5120 120 12.5 / 10.8 1 9 lbs. “Under-The-Desk” Confined Space Radiant Heat Panel • Use under desks for personal comfort or in small areas for freeze protection or moisture removal. • Built in stand. • Temperature control thermostat. Manufactured in U.S.A. • 6' long - 3 conductor cord Width: 22-3/4” Height: 8” Depth: 1-3/4” Standard Models UPC# 686334 MODEL WATTS BTU’s VOLTS PHASE WT. 450881 170-TS 170 580 120 1 9 lbs. 483 Series 120 Volt Portable Baseboard Convection Heater • 1500 Watt convection heater • Temperature control thermostat • Manual reset type limit control • Power on indicator light • 6’ long - 3 conductor cord Width: 48” Height: 5-1/4” Depth: 7-1/2” Standard Models UPC 686334 MODEL WATTS MAX BTU’s VOLTS AMPS PHASE WT. 870887 483 TM 1500 5120 120 12.5 1 13 lbs. Manufactured in U.S.A. 474 Series 240 Volt Dual Heat Fan Forced Portable Heater • 80 30 AMP Plug 2000W & 4000W heat settings Temperature control thermostat Manual reset type limit control 6’ long - 3 conductor cord • • • UPC# 686334 MODEL WATTS 446181 H474 TMC 2000 / 4000 Width: NEMA16” #6-30P Height: 16” Depth: 8-1/2” 20 AMP Plug NEMA #6-20P MAX VOLTS BTU's 13652 240 AMPS PHASE WT. 8.3 / 16.6 1 20 lbs. 5800 Series Garage/Workshop 240/208 Volt Fan Forced Portable Heater • • • • • • • Up to 4800 Watts of heating comfort for garage or utility room applications 4000 Watts available for smaller areas. ITEM Built in bi-metal double pole thermostat - 50° to 90° range. Heater Steel tubular heating element Bracket Wall/Ceiling bracket included Manual reset standard Power on and overheat pilot lights UPC# 686334 MODEL WATTS MAX BTU's 503402 HF5840TC 4000/3000 13652 503396 HF5848TC 4800/3600 15086 VOLTS 240 / 208 WIDTH HEIGHT DEPTH 10.625 11” 9.625” 2.5” 10” 14.0” AMPS PHASE 16.6 / 14.4 1 20 / 17.3 PLUG TYPE 20 Amp 30 Amp WT. (LBS) 17 ICH Series 240/208 Volt Construction Site/Utility Fan Forced Portable Heater • • • • • • 30 AMP Plug NEMA #6-30P Operates on 240V or 208V Steel tubular heating element 43°F air heat rise Internal overheat thermostat Temperature control thermostat 6’ long cordset Width: 10 5/8” Height: 12 3/4” Depth: 10” 20 AMP Plug NEMA #6-20P UPC# 686334 MODEL WATTS MAX BTU's 450874 ICH-240C 4000 / 3000 13648 VOLTS AMPS 240 / 208 16.7 / 14.4 PHASE WT. 1 15 lbs. 680 Series “Bulldog” 240/208 Volt Fan Forced Portable Unit Heater 30 AMP Plug Swivel base allows unit toNEMA be#6-30P wall, floor, or ceiling mounted. 20 AMP Plug 30 AMP Plug • Operates on 240V or 208V NEMA #6-20P NEMA #6-30P • Finned steel tubular heating element HF684TC HF685TC, HF686TC • Internal manual reset thermal cut-out • 6’ long cord with molded plug Width: 13 1/2” • Temperature control thermostat with 35°F to 85°F range Height:20 17AMP 1/2”Plug #6-20P Depth: NEMA 11 1/2” • 10’ air throw - 262 CFM UPC# 686334 MODEL 446280 *HF684TC 4000/3000 13652/10239 240/208 446297 HF685TC 446303 HF686TC 683500 A1560 * HF684TC UL listed only AMPS TEMP RISE 1 16.7/14.5 48 oF 20 lbs 4800/3600 16384/12288 240/208 1 20.0/17.4 58oF 20 lbs. 5600/4200 19107/14330 240/208 1 23.4/20.2 75 oF 20 lbs. WATTS MAX BTU's VOLTS PHASE WT. OPTIONAL WALL CEILING BRACKET FOR HF680 & ICH 240c SERIES HEATERS Specialty Heaters RPH Series Pump House Convection Specialty Heater • Provides protection against freezing for pump houses, utility rooms, relay stations, construction sheds, etc. • Aluminum finned heating element • Powder coated epoxy steel case • Automatic temperature control thermostat with a 35oF to 65oF range. • Dimension 20” x 5-1/2” x 4” Manufactured in U.S.A. Standard Models UPC# 686334 MODEL WATTS BTU’s VOLTS AMPS WT. 999083 RPH1-5A 500 1706 120 4.2 5 lbs. 999090 RPH2-5A 500 1706 240 2.1 5 lbs. 220 240 2.3 2.1 5 International Models 984263 984270 RPH22-5Ai RPH2-5Ai 500 1706 FH Series In-Floor Fan Forced Specialty Heater Manufactured in U.S.A. • Powder coated 20 gauge steel case • 14 gauge grill • Steel spiral finned heating element • Auto reset thermal cut out with audible alarm. • Floor opening: 14-1/8” x 7-1/4” x 7-3/8” • Grill dimensions: 15-13/16” x 8-13/16” Standard Models UPC# 686334 378239 MODEL FH15 WATTS BTU’s VOLTS AMPS 750 2560 120 6.25 1500 5120 120 12.5 1500/1125 5120 / 3840 240/208 6.25/5.41 WT. 15 lbs OPTIONAL FIELD INSTALLED THERMOSTATS 378277 FH1T Single Pole Integral Thermostat Kit 1lb TSH Series Fan Forced Kickspace Specialty Heater • Fits into soffits, stair risers or under utility cabinets • Finned steel heating element. • Manual reset thermal cut-out • Recessed opening: 22-3/8” x 3-5/8” x 11-1/2” Manufactured in U.S.A. • Grill dimensions: 23-7/8 x 3-5/16 Standard Models UPC# 686334 381802 970174 MODEL TSH20J TSH20JW WATTS BTU’s VOLTS AMPS 1500 / 1000 5120 / 3412 120 12.5 / 8.4 1500 / 750 5120 / 2560 208 7.2 / 3.6 2000 / 1000 6284 / 3412 240 8.4 / 4.2 WT. 16 lbs Above Model with White Grill OPTIONAL FIELD INSTALLED THERMOSTATS 378376 TSH1TX Single Pole Integral Thermostat Kit 1lb 378383 TSH2TX Double Pole Integral Thermostat Kit 1lb 81 CF & CFH Series Variable Speed Air Curtains Product Specifications CABINET: Shall be constructed of 20 gauge rigid steel with baked on epoxy powder coat paint for durability. DISCHARGE VANES: Shall extend the entire width of the unit and be adjustable for optimum performance of air flow. BLOWERS: Shall be forward curved centrifugal type, DWDI with corrosion resistance scroll and wheel. MOTORS: Shall be heavy duty, PSC, direct drive high efficiency and designed for use with SCR controllers. Motors shall be permanently lubricated for long life and have thermal over Manufactured in U.S.A. load protection. Motor shall UPC SIZE FT. / MIN. NOZZLE RPM AMPS WATTS WT. MODEL VOLTS have double insulation pro(in) HI - LOW CFM HI - LOW HI - LOW HI - LOW (lbs) 686334 tection for quieter operation. STANDARD UNITS: 1/2 HP MODELS - UP TO 10’ HIGH DOORWAYS - WITHOUT HEAT SECTION Quick disconnects shall be 671200 36 CF36 3288/455 2672/333 1659/620 3.9/3.4 472/154 74 671217 48 CF48 4168/786 4515/766 1606/583 4.4/3.6 519/189 82 supplied to accommodate 671224 60 CF60 4168/764 6544/931 1636/562 4.4/3.8 509/199 90 easy installation and service 72 2 EA: CF36 3288/455 5344/666 1659/620 7.8/6.8 944/308 148 120 of motor. 96 2 EA: CF48 4168/786 9030/1532 1606/583 8.8/7.2 1038/378 164 SCR SPEED CONTROL108 3 EA: CF36 3288/455 8016/999 1659/620 11.7/10.2 1416/462 222 1 EA: CF48 4168/786 1606/583 LER: Supplied on all units 120 9859/1432 12.2/10.4 1982/497 230 2 EA:CF36 2672/333 1659/620 compatible with the motor HEAVY DUTY UNITS: 3/4 HP MODELS - UP TO 12’ HIGH DOORWAYS - WITHOUT HEAT SECTION with low end adjustment for 671231 36 CFHD36 3288/1120 2672/819 1689/603 4.4/4.3 603/192 77 air volume control and sav671248 48 CFHD48 4256/929 4611/906 1662/500 5.9/4.8 586/168 85 671255 60 CFHD60 4256/924 5763/1126 1652/509 5.2/4.4 708/172 93 ings in power consumption. 72 2 EA: CFHD36 3288/1120 5344/1638 1689/603 8.8/8.6 1206/384 154 ELECTRIC HEAT (OPTION120 96 2 EA: CFHD48 4256/929 9222/1812 1662/500 11.8/9.6 1172/336 170 AL): Electric heater available 108 3 EA: CFHD36 3288/1120 8016/2457 1689/603 13.2/12.9 1809/576 231 as field installed option. Elec1 EA: CFHD48 4256/929 1662/500 120 9955/2544 14.7/13.4 2981/552 239 2 EA: CFHD36 3288/1120 1689/603 tric heater shall be steel sheath element with helical wound EXAMPLE steel fins for maximum heat Use the example shown (left) to order unit with heat section Model # Unit Width KW Volts Phase transfer and safety. by specification CFHTR 36 MODEL HEATER WIDTH Air Curtain with Heater Module NOTE: All heating sections are constructed of totally enclosed fin tubular elements for safety and longer operating life. With heating section installed, unit becomes a 24 Volt control unit and can utilize a low voltage thermostat for control of heating. NOTE: For 72” through 120” units, order multiple heater modules corresponding to the actual air curtain models | 36, 48, or 60 Inch Width NOTE: 12KW MAXIMUM ON 36” WIDTH UNITS | CFHTR 82 10.0 | 208 | 3 | KW VOLTS PHASE 3 5 7.5 10 12 15 208 240 480 277 208 240 208 240 480 277 208 240 208 240 480 277 208 240 208 240 480 277 240 208 240 480 277 208 240 480 3 1 3 1 3 1 3 1 3 1 3 HEATER AMPS 8.3 7.2 3.6 10.8 14.4 12.5 13.8 12.0 6.0 18.0 24.0 20.8 20.8 18.0 9.0 27.0 36.0 31.2 27.7 24.0 12.0 36.1 41.6 33.3 28.8 14.4 43.3 41.6 36.0 18.0 MINIMUM CIRCUIT AMPS 10.4 9.0 4.5 13.5 18.0 15.6 17.25 15.0 7.5 22.5 30.0 26.6 26.0 22.5 11.3 33.8 45.0 39.0 34.4 30.1 15.0 45.1 52.0 41.6 36.0 18.0 54.1 52.0 36.0 18.0 MAXIMUM FUSE AMPS 15 15 15 15 20 20 20 20 15 25 35 30 30 25 15 40 50 45 40 35 20 50 60 45 40 20 60 60 55 30 BTUH 10,239 17,075 25,597 34,130 40,956 51,195 75°C WIRE AWG 14 14 14 14 12 12 12 12 14 10 8 10 10 10 14 8 6 8 8 8 12 6 6 8 8 12 6 6 6 10 SD Series - Setback on Demand Thermostat FULLY AUTOMATIC: All the savings without any of the hassles of a programmable thermostat. Once installed, everything is automatic. When people are present it automatically controls to the comfort setting. When they leave, it automatically returns to the economy setting. SMART COMFORT: The SD thermostat learns your schedule so you arrive to a comfortable temperature. Holidays are no problem. When no-one arrives, it automatically returns to the economy setting. AUTO-CHANGEOVER: Our Auto-Changeover doesn’t limit your comfort settings. We incorporate an adjustable deadband to protect your equipment while maintaining comfort. Factory set at 1 degree, but adjustable from 1-5 degrees. ONE MODEL WORKS WITH ALMOST ANY LOW VOLTAGE SYSTEM.: The SD thermostat works with low voltage systems up to 4 stages of heat, 4 stages of cool, or any combination up to a total of 4 stages including Heat Pumps. Patent Pending UPC# 686334 MODEL COLOR TYPE 523646 SDHW1001 White Hardwire Thermostats & Controls ET Series - Line Voltage Features • Single pole and double pole • Heat only, cool only, & heat or cool • DP models include positive off • Celsius and Fahrenheit temperature scale • Optional Thermometer • 22 Amps, 277 Volts AC UPC # 686334 538725 538732 538886 538749 538756 538763 538770 538787 538794 538800 538893 538817 538824 538831 538848 538855 538862 MODEL 83 DESCRIPTION AET5DWS Double Pole 22 Amp, 120-277V with leads, Anticipator AET5SWS Single Pole 22 Amp, 120-277V with leads, Anticipator ET5DS Double Pole 22 Amp, 120-277V, Heat Only ET5D4S Double Pole 22 Amp, 120-277V, 35-75oF Temp Range ET5DTS Double Pole 22 Amp, 120-277V, with Thermometer, Heat Only ET5DWS Double Pole 22 Amp, 120-277V, Heat Only with Leads ET5MS Heat Only, 2 Stage ET5SS Single Pole 22 Amp, 120-277V, Heat Only ET5S4S Single Pole 22 Amp, 120-277V, 35-75oF Temp Range ET5SRS Single Pole 22 Amp, Cooling Only ET5SRTS Single Pole Cool with Thermometer ET5STS Single Pole 22 Amp, Heat Only with Thermometer ET5SWS Single Pole 22 Amp, Heat Only with Leads ETD5MS Double Throw, 2 Stage Heat, 1 Stage Cool ETD5MTS 2 Heat, 1 Cool with Thermometer ETD5SS Single Pole Double Throw Heat/Cool ETD5STS Single Pole Double Throw Heat/Cool with Thermometer EPET Series and HLT Series Hazardous Location Motor Rating (full load): 3/4 HP @ 125V, 1-1/2 HP @250V Pilot Duty Rating 125VA @ 24VAC NEMA Class Seven Div. 1 Approved Class I Group C & D, Class II Group E, F, & G Not rated for Group B Features • • • • • • • • SPDT & DPDT Models Heat or cool compatible Celsius and Fahrenheit temperature scale Bi-Metal or capillary sensor Snap action switch Casting tapered top and bottom for 3/4” conduit 1/2” thick cast Aluminum housing Dimension 5-3/4” x 6-3/8” x 5.57” UPC# 686334 MODEL DESCRIPTION LOAD RATINGS RANGE 538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF 538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF 528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF 528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF 523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110oF 523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110oF Master ctn: 4 pcs, 24 lbs (varies slightly by model), 16” x 14.5” x 6” EPET Series incorporate plastic knob & Bi-Metal Sensor housing. HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb and capillary sensor. 2000 Series - Line Voltage UPC# 686334 MODEL COLOR 502849 S2022H10AA White 502436 S2022H10AB Ivory 502856 D2022H10BA White 502443 D2022H10BB Ivory 502917 S2025H10AA White Single Pole with leads, 25 Amp 502924 D2025H10BA White Double pole with leads, 25 Amp DESCRIPTION Single Pole with leads, 22 Amp Features • White or Ivory • Single pole and double pole • Heat Only • DP models include positive off • 22 Amps, 277 Volts AC Double pole with leads, 22 Amp Thermostats & Controls TW Series 84 Load Rating Features • 22 Amps resistive @ 120 VAC • 18 Amps resistive @ 277 VAC • Single and double pole models • Wire leads • Tamper resistant UPC# 686334 MODEL DESCRIPTION TEMPERATURE SCALE 502009 TW145 SP, Beige with Leads Tamper Resistant 502016 TW146 DP, Beige with Leads Tamper Resistant Master Carton: 25 Pcs, 12 lbs. (varies slightly by model), 16” x 14” x 5.5” Washdown Series Features • Stainless steel hardware • Coil capillary temperature sensor • Single and double pole models • Rain tight NEMA 4X rating UPC# 686334 MODEL DESCRIPTION TEMPERATURE SCALE 523424 TW155A SP, Rain tight 40-110oF 523431 TW255A DP, Rain tight 40-110oF 22 Amps @ 120/250/277 VAC, 5” x 5” x3” Case Industrial Series Features • Coil capillary (CKT) models • Bi-Metal models (KT) • Rugged steel case • SPST & SDPT models • Hard wired models rated for 22A resistive @125-250 VAC • Corded models rated for 13A resistive @125VAC UPC# 686334 MODEL DESCRIPTION RANGE CONNECTIONS 534048 CKTD110 SPDT Heat or Cool 40 - 110oF Wire Leads F 534086 KT110 SPST Heat Only -10 - 100oF Wire Leads C&F 534109 KT121 SPST Heat Only -10 - 100oF 6’ Cord/Plug C&F 534178 KTD110 SPDT Heat or Cool -10 - 100 F Wire Leads C&F 534369 KTO110 SPST Cool Only -10 - 100oF Wire Leads C&F 534215 KTO121 SPST Cool Only -10 - 100 F 6’ Cord/Plug C&F o o SCALE Master Carton: 13.75” x 14” x 9”, Qty 9-12, 14lbs.-16lbs. depending on model L Series Features • 6’ or 8’ Capillary • Rugged steel cage • SPDT for Heat or Cool • 25A resistive • Rated differential of 6°F UPC# 686334 MODEL DESCRIPTION RANGE CAPILLARY SCALE 534260 L06Y-01 SPDT Heat or Cool 0 - 90oF 6’ F 534277 L08Y-01 SPDT Heat or Cool 0 - 90oF 8’ F Master Carton: 13.75” x 14” x 9”, 12 Pcs, 18lbs. Thermostats & Controls Electromechanical Humidistat 85 Features • 4.4 amp @ 120VAC • 2.2 amp @ 240VAC • 50VA @ 24VAC - 240VAC • 10% - 60% relative humidity range Standard Models UPC# 686334 MODEL DESCRIPTION 523370 H46D1214 Humidistat/Electromechanical Electromechanical De-Humidistat Features • 4.4 amp @ 120VAC • 2.2 amp @ 240VAC • 50VA @ 24VAC - 240VAC • 10% - 60% relative humidity range Standard Models UPC# 686334 MODEL DESCRIPTION 589147 H1D1AA Dehumidistat/Electromechanical Honeywell Line Voltage Thermostats Features • Heat only thermostats • Accurate temperature control • 22 Amp resistive for mechanical models Standard Models T4398A 1021 Precision Mechanical UPC# 686334 MODEL VOLTAGE DIMENSIONS DESCRIPTION 503303 T4398A 1021 120-240 2.875”x4.375”x2.00D Precision Electric Heating. SPST, 50-80 OF, 22 Amp @ 120-240V 19 Amp @ 277V Features • Heat only thermostats • Accurate temperature control • 16 Amp resistive for electronic models • Energy Star compliant. Standard Models UPC# 686334 MODEL 503365 TL8230A 1003 TL8230A 1003 Electronic Programmable VOLTAGE DIMENSIONS DESCRIPTION 240/208 2.70”x4.90”x.90D Electronic Programmable Line Voltage DPST, 15 Amp, 40-86 OF Wireless RF Interface Series Features RFT-1 RFT-1 shown with UT thermostat RFR-5 • Heat only, Cool only • Works with most low voltage • 4 wire Heat/Cool thermostats • Standard 2 stage Heat/ 1 Stage Cool Heat Pumps • Temp Range: 50-130 F • Multistage heating and/or cooling equipment • Max Operating Range: 50 Feet UPC# 686334 MODEL 523554 RFT-1 523561 RFR-5 523578 RFKit-5 DESCRIPTION RF Thermostat Transmitter Dim: 4” x 5” x .875” RF Relay Interface Dim: 4.5” x 6” x 1.25” RFT-1 & RFR-5 Package VOLTAGE CONNECTIONS 2-AAA Batteries 6 Wires 24 VAC 2 AAA 24 VAC R-C-R1 1-2-3-4-5 R-C-R1 1-2-3-4-5 Thermostats & Controls Low Voltage Programmable Thermostats 86 Features • 7 Day, 4 Settings Per Day • Control Accuracy +/- 1oF of Setpoint Temp • Pre-Programmed or Custom Settings • Backlit Display, Energy Star Compliant Standard Models UPC# 686334 MODEL DESCRIPTION Heat Only Temp Range:40-86OF Dims:4.89”H x 2.79”W x .91”D 523400 TH115-A-024T TH115-A-024T Features • 7 Day, 4 Settings Per Day • Control Accuracy +/- 1oF of Setpoint Temp • Pre-Programmed or Custom Settings • Backlit Display, Energy Star Compliant Standard Models TH147-P UPC# 686334 MODEL DESCRIPTION 523585 TH147-P 7 Day, 4 Settings per Day, Heating/Cooling, 1 Stage Heat/Cool Temp Range Heat:41-82OF, Cool:59-95OF Dims: 5”W x 3”H x 1”D, 2 Stage Low Voltage Thermostat Features • 24V single or 2 stage heat and cool • Gas, oil, or electric with air conditioning. • Heat only, Heat only with fan, Cool only. • Battery only, common wire only or common wire with battery backup. • System settings - Heat, Off, Cool, Auto, Emergency Heat. • Temperature range - Heat 40-90oF, Cool 50-99oF. • Dimensions: 3-9/16” H x 5-13/16” W x 1-1/2” D Standard Models TW123 UPC# 686334 MODEL VOLTAGE TEMP RANGE MAX AMP 691116 TW123 / TH5220D 750MV - 2DV 40-90 Heat 50-99 Cool 1.0 Round - Low Voltage Features • Heat only for 24V heating systems • White color • Temperature range - 50o - 90oF • Does not contain Mercury • Dimensions 3-11/16” diameter Standard Models UPC# 686334 MODEL DESCRIPTION VOLTAGE MAX AMP 260008 A6176 Heat/Cool 24 VAC 1.0 Thermostats & Controls UT Series - Low Voltage Features • Vertical or horizontal mounting • Long life sealed contacts • Does not contain Mercury • Leveling not required 87 • Fahrenheit and Celsius temperature scales • 2-3oF rated differential • Anticipator (except UT9001) Standard Models UPC# MODEL DESCRIPTION 686334 VOLTAGE TERMINALS SWITCHES 523059 UT1001 Heat Only 24VAC or MV R &W None 523066 UT3001 Cool Only 24 VAC R, Y & G Cool/Off Fan/Auto 523134 UT6001 Deadband 24 VAC R, W & Y None 523073 UT8001 Heat/Cool 24 VAC 523110 UT9001 Heat Only Millivolt RC, RH, W, Y, & G Heat/Off/Cool Fan/Auto R&W None Master Carton: 50 pcs, 17 lbs, 19” x 11.5” x 9” RK Series - Low Voltage Features • Heat only models • Does not contain Mercury • Fahrenheit and Celsius temperature scales • Leveling not required • Positive off o • Long life sealed contacts • 2-3 F rated differential Standard Models UPC # 686334 526012 526203 526050 526326 526142 MODEL DESCRIPTION RK120EAA RK124EAA RK130EAA RK134EAA RKWP1AA VOLTAGE RANGE Heat Only 24VAC or MV 50 -90 F Heat Only 24VAC or MV 35o-75oF Heat Only Millivolt 50o-90oF Heat Only Millivolt 35o-75oF Wall Plate NA NA Master Carton: 100 Pcs, 24 lbs, 16.5” x 15” x 8” o o ANTICIPATOR Yes Yes No No NA Low Voltage Relays • Snap action switch • 1/2” male conduit spud Features • 45 second average time delay • Temperature range - 50o - 90oF • Built-In transformer Standard Models Two switch unit shown. UPC# 686334 MODEL PRIMARY VOLTAGE 260039 24A05A-1 120 Volts 260046 24A05E-1 208 Volts 260053 24A01G-3 240 Volts 260107 24A06G-1 240 Volts DESCRIPTION Single Switch, single throw with In-Built Transformer for remote mounting or in a factory provided optional enclosure Two switch, single throw with In-Built Transformer, 25 Amps per switch TG Series Thermostat Guards Standard Models Features • 8 tumbler locks UPC# 686334 589123 589109 589130 589161 589116 589178 523615 523622 523639 MODEL TG1 TG1B TG2 TG2B TG3 TG3B TG4 TG5 TG6 DESCRIPTION Plastic Stat Guard/ 6.25” x 3.625” x 3.25” Opening Metal Stat Guard/ 5.25” x 4.625” x 3” Opening Plastic Stat Guard/ 5.25” x 4.625” x 3.25” Opening Metal Stat Guard/ 6.25” x 3.625” x 3.25” Opening Plastic Stat Guard/ 8.125” x 4.625” x 3.625” Opening Metal Stat Guard/ 6.75” x 4.50” x 3.50” Opening Plastic Stat Guard / 3.50” x 3.937” x 1.75” Opening Plastic Stat Guard / 5” x 3.31” x 1.75” Opening Plastic Stat Guard / 5.75” x 4.625” x 1.75” Opening Thermal Area Treatment Heaters 88 Sizing formula for TAT Series heaters: 50 Watts of heat per square foot of heated space or 50W/sq ft. Example: An 800 square foot structure will require 40,000 Watts of heat to obtain 150 degrees of prolonged heat to be effective. (800 sq ft x 50 Watts per square foot = 40,000 Watts of heat or 40KW of heat) Product Features • Heavy duty industrial construction • Forward curved centrifugal blower • High Temperature ball bearing motor • Optional replaceable filter • Single point power connection • 24 volt control • Heavy duty spiral finned elements constructed of stainless steel • Safety devices include airflow switch, automatic limit control and manual reset limit control for secondary protection • Disconnect switch and Unit Mounted Thermostat with range of up to 120 to 150 oF • The “TAT” series is sold as a system that includes the base unit, three supplemental units and the remote timer/ temperature control (supplemental units may be purchased separately if necessary) Product Specifications APPLICATIONS: • The "TAT" series is designed to heat small and mid-sized rooms up to 150 oF. This provides effective portable heating to areas infected with insects. It kills adult insects and will dehydrate larvae and eggs, making them unable to hatch. Although chemical sprays only target adult insects, they can be used before utilizing the "TAT" system in order to kill the adult insects. • The system is designed to bring the temperature up to 150 oF in one hour or less, if all preliminary requirements are met. • The "TAT" system may be used for water remediation, as well, in combination with adequate ventilation. Specific models for water remediation are also available. TAT BASE UNIT: • Heavy duty stainless steel spiral fin heating elements • High temperature, ball bearing 1/3 HP - 1075 RPM blower motor • Forward curved centrifugal blower-900 CFM of air output • Safety devices include airflow switch, disconnect switch, automatic limit control and manual reset limit control for secondary protection • 50 Amp unit may be linked to a 30 Amp unit to provide heating for larger spaces. • Timer/Temp controller may be used to control both units but must use the 50 Amp base unit as the master. SUPPLEMENTAL TAT CONVECTORS • 3 convectors are an integral part of each TAT system • 120 Volt, 15 Amp (Standard wall plug) - 5120 BTU size • Supplied with 25' prewired cable that connects them to the TAT base unit control section with a three pin connector • If used in front of windows or large glass doors, they will reduce heat loss and provide more even heating TIMER/TEMPERATURE CONTROL UNIT • Timer/Temp Controller is an integral part of the TAT system • 24 Volt control device that controls the heat output of the TAT base unit and up to three TAT convectors for an operating range of 120 - 150 oF and for a time period of 1 -10 hours after the preset temperature is reached • Supplied with a 25' prewired cable that connects to the TAT base unit control section using a four pin connector • Mounts on Door outside the area being treated. • LED lights will indicate when treatment is complete Thermal Area Treatment Heaters Standard Models UPC# 686334 BASEBOARD BASE BASEBOARD TOTAL BASE BASE PERIMETER UNIT PERIMETER SYSTEM UNIT PHASE UNIT HEATER KW HEATER KW KW VOLTS AMP VOLTS STYLE MODEL NUMBER BASEBOARD PLUG TYPE PERIMETER AMP-EACH BASE UNIT PERIMETER CIRCUIT (3) 397568 TAT5-240-1/3BB/1T 5.3 1.5 (X3) 9.8 240 120 1 24 12.5 Nema 10-30 Nema 5-15 397629 TAT5-208-1/3BB/1T* 5.3 1.5 (x3) 9.8 208 120 1 27 12.5 ---- Nema 5-15 397551 TAT8-240-1/3BB/1T 8.4 1.5 (X3) 12.9 240 120 1 37 12.5 Nema 14-50 Nema 5-15 397612 TAT8-208-1/3BB/1T* 8.4 1.5 (x3) 12.9 208 120 1 42 12.5 ---- Nema 5-15 397520 TAT20-480-3/3BB/1T 20 1.5 (X3) 24.5 480 120 3 26 12.5 397582 TAT-ILC-25 Nema L16-30 Nema 5-15 25’ Shielded Cable *208 Volt models do not have a cord supplied Accessories UPC# 686334 MODEL DESCRIPTION HP CFM / RPM MAX AMPS VOLTS WT (LBS) 397636 TAT-24-FAN-120V-1 Thermal Area Treatment Floor Fan 1/3 5000/1160 3.1 120 30 UPC# 686334 397834 397841 MODEL DESCRIPTION KW BTU VOLTS PHASE AMPS TEMP RISE WT (LBS) TAT-30 30KW Salamander 30 102390 480 3 36 43 115 TAT-45 45KW Salamander 45 153585 480 3 54.2 70 125 Product Dimensions TAT 30-45 W L W L H H CORD LENGTH: 25' 18AWG SHIELDED CABLE L H • Safety yellow heater enclosure with safety screens on both air intake and output openings. • Optional 25’ long SO type cord, ready for plug attachment is available for each model. H • Long-life finned tubular heating elements. • Thermostat adjustment 120° to 150° F. • Two 10” rear wheels and a front locking caster. • High-limit thermal cutout switch with manual reset. • 2200 CFM • Fan only operation feature 5" L W 7" W CORD LENGTH: 6'10" 16AWG USASI HPN CORD 10.625" 3" 5" CORD LENGTH: 25' 18AWG SHIELDED CABLE HANDLE ADDS 6" TO L" CORD LENGTH: 6'10" 16AWG USASI HPN CORD 7" 3" 48" 10.625" TAT-24-FAN-120V-1 HANDLE ADDS 6" TO L" • Single speed • Head tilts 360o • Coated steel guards • SJT type 3 conductor • Steel hub / Aluminum blades • Meets OSHA standards H L H 8.75" 48" L 8.75" W W MODEL TAT-8-240-1 TAT-5-240-1 TAT-20-480-3 TAT-1-120-1 Remote Timer TAT 30, 45 TAT24-FAN-120V-1 LENGTH 39” 39” 39” 48” 11” 37” 10.5” DIMENSIONS WIDTH 26.5” 26.5” 30.5 8.5” 3” 24” 26” HEIGHT 18” 18” 18” 9.5” 4.5” 39” 26” WT. (LBS) 180 180 234 23 5 115/125 30 89 Thermal Area Treatment Heaters How It Works: 90 Move dryer, connect 30 Amp unit to 30 Amp dryer power supply. Dryer 30 Amp Power Supply Washer Heater Line 1 30 AMP TAT Base Unit Heater Line 2 Seal all exterior windows and doors before extermination process begins. Move range/electric stove, connect 50 Amp unit to 50 Amp range power supply. Heater Line 3 Stove/Range ply er Sup p Pow 50 Am er. th er th l Te ro ge nt to Co ed us nit are eU lav ems r/S st ste o sy w if t ly on Ma e Us Heater Line 2 Timer Control Lin Heater Line 3 e Heater Line 1 50 AMP TAT Base Unit Timer Control Unit Diagram is for demonstrative purposes only and does not represent any actual structure or living environment. Two units may not be required for all situations, exterior climate, structure insulation, electrical service, and square footage all factor into effective treatment with this system. Hotpod™ Supplemental Duct Mounted Heating System HotPod - Features 8” Hotpod • Use to heat cold rooms or additions without upgrading central system • Fan only operation for increased cfm output for A/C cycles • 6" 1000/500 Watt and 8" 1440/720 Watt models available • Two stage operation • 120V corded and hard wire models available • 10' Cord length on corded models • Zero clearance for all models • All models include UT8003 low voltage thermostat • Optional wireless thermostat • Silent boot option available for rigid duct applications 6” Hotpod Patented Patent No. 8,285,127 Note: Silent Boot can only be used with rigid duct work Standard HotPod Models UPC# 686334 MODEL 290074 HP6-1000120-2T 290043 HP6-1000120-2CT 290081 HP8-1440120-2T 290067 HP8-1440120-2CT DESCRIPTION WATTS VOLTS 6” INLET, HARDWIRE 6” INLET, WITH CORD SET 8” INLET, HARDWIRE 8” INLET, WITH CORD SET 1000/500 1000/500 1440/720 1440/720 120 120 120 120 MIN.CIRC. TEMP NEMA WT RPM CFM SIZE (AMP) RISE (F) PLUG 8.33 8.33 12.6 12.6 26 26 23 23 4 4 6 6 1500 1500 1500 1500 130 130 210 210 NA 5-15P NA 5-15P DIMENSION LXWXH 10 1/2 x 8 1/2 x 6 10 1/2 x 8 1/2 x 6 11 x 10 1/2 x 8 11 x 10 1/2 x 8 Multi-Pak Models - Includes 4 Hotpods UPC# 686334 MODEL 290036 HP6-1000120-2T 290111 HP6-1000120-2CT 290050 HP8-1440120-2T 290128 HP8-1440120-2CT 290333 HP6H-12PK* 290340 HP6C-12PK* 290357 HP8H-12PK* 290364 HP8C-12PK* DESCRIPTION WATTS VOLTS 4 PACK 6” INLET, HARDWIRE 4 PACK 6” INLET, WITH CORD SET 4 PACK 8” INLET, HARDWIRE 4 PACK 8” INLET, WITH CORD SET 12 PACK 6” INLET, HARDWIRE 12 PACK 6” INLET, WITH CORD SET 12 PACK 8” INLET, HARDWIRE 12 PACK 8” INLET, WITH CORD SET 1000/500 1000/500 1440/720 1440/720 1000/500 1000/500 1440/720 1440/720 120 120 120 120 120 120 120 120 TEMP MIN.CIRC. WT. NEMA RISE RPM CFM SIZE (AMP) LBS PLUG (F) 8.33 8.33 12.6 12.6 8.33 8.33 12.6 12.6 26 26 23 23 26 26 23 23 16 16 25 25 58 58 82 82 1500 1500 1500 1500 1500 1500 1500 1500 130 130 210 210 130 130 210 210 DIMENSION LXWXH NA 10 1/2 x 17 x 12 5-15P 10 1/2 x 17 x 12 NA 10 1/2 x 20 x 16 5-15P 10 1/2 x 20 x 16 NA 21 x 14 1/2 x 43 5-15P 21 x 14 1/2 x 43 NA 27 1/4 x 14 1/2 x 52 5-15P 27 1/4 x 14 1/2 x 52 *includes 1 HotPod display Note: Multi-Pak specifications (watts, volts, etc) are for each individual hotpod in the pack excluding weight. Silent Booster™ Supplemental Duct Mounted Boosting System 6” Silent Booster 8” Silent Booster Silent Booster - Features • 120V corded and hardwire models available • Adds 120 CFM Boost to duct heating or ventilation applications • Can utilize optional TPI SilentBoot™ for whisper quiet operation in rigid duct application. • 14” of duct, 4’ from register is all that is needed for installation • Optional wireless thermostat can be utilized to control Silent Booster™ to increase room comfort Standard Silent Booster Models UPC# 686334 290371 290388 290395 290401 MODEL DESCRIPTION VOLTS SB6-120-T SB6-120-CT SB8-120-T SB8-120-CT 6” SILET BOOSTER (Hardwire) 6” SILENT BOOSTER (w/Cord Set) 8” SILET BOOSTER (Hardwire) 8” SILENT BOOSTER (w/Cord Set) 120 120 120 120 MIN.CIRC. SIZE (AMP) 15 15 15 15 WT RPM CFM 4 4 4 4 1500 1500 1500 1500 130 130 210 210 NEMA PLUG NA 5-15P NA 5-15P DIMENSION LXWXH 10 1/2 x 8 1/2 x 6 10 1/2 x 8 1/2 x 6 11 x 10 1/2 x 8 11 x 10 1/2 x 8 91 Hotpod™ Accessories, Thermostats, Ready-Pack, and MFH Models Hotpod Accessories And Thermostat 92 UPC# 686334 MODEL DESCRIPTION WT 290098 SB-6* 6” SILENT BOOT 4 290104 SB-8* 8” SILENT BOOT 4 523578 RFKIT-5 WIRELESS TRANSMITTER 6 * Can be used with Hotpod models as a noise attenuator Silent Boot RFT-1 ( Shown With UT8003 Thermostat) Hotpod Ready-Pack Self Contained Systems Ready-Pack self contained system Note: does not mount to exsisting duct work. Features • Includes all you need to install a complete Hotpod system • Ideal for room or office additions • RF Thermostat is standard with our Ready-Pack models, simplifying installation even further - Eliminates the need for thermostat wiring. • Same specifications for 6” and 8” Hotpod models apply to Ready-Pack models. RFR-5 RFKIT-5 - Patent Pending What’s Included • 6” or 8” Hotpod with RFKIT-5 wireless thermostat and transmitter • One outlet and one return air grill • Two 90 degree elbows • Flexible duct (12.5’) • 8" models include 2 reducers - 8” to 6” MODEL DESCRIPTION HP6-1000120-2TRP HP6-1000120-2CTRP HP8-1440120-2TRP HP8-1440120-2CTRP 6” INLET, 1000W, 120V, READY-PACK 6” INLET, 1000W, 120V, READY-PACK WITH CORDSET 8” INLET, 1440W, 120V, READY-PACK 8” INLET, 1440W, 120V, READY-PACK WITH CORDSET MFH Series Hotpod - For those LARGER areas Features • When the standard Hotpod is not enough • 240V model has 6’ cord set with a NEMA-6-15P Plug • Unit contains air flow switch • Zero inch (0”) clearance installation • All units are shipped with our UT8003 low voltage thermostat • All units obtain a 33 degree temperature rise • RP models are Ready-Pack models and do not need existing duct work Standard Models UPC# 686334 290135 290197 290142 290203 290173 290234 290159 290210 290166 290227 290180 290241 MODEL DESCRIPTION WATTS VOLTS WT CFM RPM 1500 1500 1500 1500 2000 2000 1500 1500 1500 1500 3000 3000 120 120 120 120 240 240 120 120 120 120 240 240 132 145 132 145 132 145 135 148 135 148 135 148 250 250 250 250 250 250 250 250 250 250 250 250 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 MFHE-0300-6-EAA 6" INLETS, 1500 W, 120V,2 STAGE THERMOSTAT MFHE-0300-6-EAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS MFHE-0300-6-EAAC 6" INLETS, 1500 W, 120V,2 STAGE THERMOSTAT, CORD MFHE-0300-6-EAACRP UNIT ABOVE WITH FLEX, BOOTS, GRILLS MFHE-0300-6-HAA 6" INLETS, 2000W, 240V, 2 STAGE THERMOSTAT MFHE-0300-6-HAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS MFHE-0300-8-EAA 8" INLETS, 1500W, 120V, 2 STAGE THERMOSTAT MFHE-0300-8-EAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS MFHE-0300-8-EAAC 8" INLETS, 1500W, 120V, 2 STAGE THERMOSTAT,CORD MFHE-0300-8-EAACRP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS MFHE-0300-8-HAA 8" INLETS, 3000W, 240V, 2 STAGE THERMOSTAT MFHE-0300-8-HAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS Fresh Air Make Up Units - Features • Can be used with existing systems for fresh air intake • Includes replaceable filter • All units include duct stat and disconnect switch • Available with 6" inlet and outlet only Standard Models UPC# 686334 290258 290265 MODEL DESCRIPTION CFM RPM MFHE-0300-6-HAAF2D MFHE-0300-6-FAAF2D 6" INLETS, 3000W, 240V, FILTER, DUCT STAT 6" INLETS, 2000W, 208V, FILTER, DUCT STAT 250 250 1500 1500 7200 Series Plenum Heater 93 2 T Control System T = Unit Thermostat SSR = SSR Control F = 208V Series Number 15 Blank = None 1 = Single Phase Motor Voltage E = 120 G = 277 P = 480 72 Heater Stages Blank = One 2 = Two E Phase 3 = Three Phase 3 H = 240V Element Voltage G = 277V P = 480V F Element KW 3KW through 50KW See model chart for KW options. HOW TO DESIGNATE A MODEL: Manufactured in U.S.A. Product Specifications • 20 gauge galvanized cabinet. • Variable speed motor, factory set at maximum. Motor speed can be field adjusted to increase heat rise. • Acoustically insulated with 1” fiberglass. • Access panels on both sides of cabinet. • 24 Volt controls. • Air flow switch. • Terminal blocks. • Single point connection. • Dust tight control enclosure. • Filter rack on inlet with throw away filter. • Inlet and outlet screens and duct connection. • Automatic primary limit control and secondary fuse link. • Optional wall thermostat, unit thermostat or SSR control which proportionally regulates heat output. • Disconnect switch. Standard Models UPC# 686334 MODEL 617680 606561 606240 606905 617765 617574 617666 617956 606165 606424 617994 606110 606554 617734 617581 606516 534390 617659 608602 608848 606257 606943 534406 606066 608831 534413 606394 534420 617888 606875 534437 606745 618007 606851 534444 606417 F1G7203 H1G7203 G1G7203 F3G7203 H3G7203 P3G7203 F1G7205 H1G7205 G1G7205 F3G7205 H3G7205 P3G7205 F3E7210 H3G7210 P3G7210 F3E7210-2 H3G7210-2 P3G7210-2 F3E7215 H3G7215 P3G7215 F3E7215-2 H3G7215-2 P3G7215-2 F3E7220-2 H3G7220-2 P3G7220-2 F3E7223-2 H3G7223-2 P3G7225-2 H3G7230-2 P3G7230-2 P3G7235-2 P3G7240-2 P3G7245-2 P3G7250-2 KW 3 5 10 15 20 23 25 30 35 40 45 50 CFM RANGE 70-270 200-650 500-1200 500-1200 750-1600 1300-2000 1800-2800 2000-3600 SSR proportional control maximum: 45 Amps VOLTS / PHASE 208/1 240/1 277/1 208/3 240/3 480/3 208/1 240/1 277/1 208/3 240/3 480/3 208/3 240/3 480/3 208/3 240/3 480/3 208/3 240/3 480/3 208/3 240/3 480/3 208/3 240/3 480/3 208/3 240/3 480/3 240/3 480/3 480/3 480/3 480/3 480/3 TOTAL AMPS for MOTOR & HEATER 15.4 13.5 11.83 9.32 8.21 4.6 25.13 21.93 19.15 14.97 13.12 7.11 33.05 25.75 13.72 33.05 25.75 13.72 46.93 37.78 19.74 46.93 37.78 19.74 63.81 50.61 26.55 74.84 59.63 34.37 78.47 42.38 48.39 56.71 62.72 68.74 STAGE 1 1 1 1 2 1 2 2 2 2 2 Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges. MOTOR VOLTAGE FULL LOAD AMPS for MOTOR ONLY 277 277 277 277 277 277 277 277 277 277 277 277 120 277 277 120 277 277 120 277 277 120 277 277 120 277 277 120 277 277 277 277 277 277 277 277 1 1 1 1 1 1 1.1 1.1 1.1 1.1 1.1 1.1 5.3 1.7 1.7 5.3 1.7 1.7 5.3 1.7 1.7 5.3 1.7 1.7 8.3 2.5 2.5 11 4.3 4.3 6.3 6.3 6.3 8.6 8.6 8.6 MOTOR H.P. WT. (LBS) 1/15 98 1/6 118 1/4 141 1/2 163 3/4 201 2 MOTORS @ 1/2 H.P. EACH 278 2 MOTORS @ 3/4 H.P. EACH 319 7200 Series Plenum Heater Product Dimensions 94 DIMENSIONS 3” 3" FILTER =AxB FILTER=A X FFilil BB terte Rra R cka LL ck Air Air Inlet Inlet InletInlet Screen Screen * 5 1/2” 5 1/2" STANDARD STANDARD 2”2" HH A A DD ScSicsircshcaha ree eenrgrge n e 7200 Series A B L DIMENSIONS 3 KW 12” 14” 28” 7200 A14” B 18” L 36” 5 KW SERIES 103& KW 15 KW12" 18” 14" 18” 28" 36” 5 20KW KW 14" 18” 18" 22” 36" 36” 10&15 23 & 25KW KW18" 18” 18" 26” 36" 36” 20 KW W 22" 36" W H 14” 8” DISCHARGE W 18” H 8” 14" 18” 8" 10” 18" 22” 8" 10” 18" 26” 10" 10” 22" 10" Control Panel Access Standard as Shown For Panel on Opposite Side Access Specify And Order Figure 5. * Control box depth depends on actual components. Consult factory for exact dimensions. ACCESS ACCESSDOORS DOORS ONBOTH BOTHSIDES SIDES ON OFOF UNIT UNIT W R AIAi 18" DISCHARGE Note: Control panel access standard as shown. 26" and10" 23&25 18" 26" 36" specify For panelKW on opposite side access order (Figure 5). Note: 1”1" FILTER SLOT Filter Slot Disconnect Disconnect Switch Switch w lo OW FrL F B ELECTRIC ELECTRIC CONTROL CONTROL PANEL PANEL 3”3" B FFilil terte r Ra R ckac LL k * HH D Sc SisDccirshcaha ree eenrgrge n e 2”2" 5STANDARD 1/2’ STANDARD 5-1/2" AA Disconnect Disconnect Switch Switch W W DIMENSIONS 7200 SERIES 7200 Series DIMENSIONS A A B B L 18 44 25-30-35 KW 18” 44” 40-45-50 KW 18 40-45-50 KW 18” 52” 36” 52 36” 25-30-35 KW DISCH'GE W X H DISCHARGE H 10” 10 10” L 44WX 10 36 44” 52 X 52” 36 NOTE: Control Panel Access Note: Control panel access Standard as Shown standard as shown. For panel For Panel on Opposite on opposite side access specify Side Access Specify Figure and And orderOrder (Figure 5). 5. Electric ELECTRIC Control CONTROL Panel PANEL FilterSLOT Slot 1” 1" FILTER ACCESS AccessDOORS ON BOTH SIDES On Both Sides Of Unit OF UNIT 7300 Series Plenum Heater T Blank = None Control System T = Unit Thermostat SSR = SSR Control 2 Heater Stages Blank = One 2 = Two Element KW 3KW through 18KW See model chart for KW options. Motor Voltage E = 120 G = 277 P = 480 73 15 Series Number E 1 = Single Phase 3 F = 208V H = 240V Element Voltage G = 277V P = 480V F Phase 3 = Three Phase HOW TO DESIGNATE A MODEL: Manufactured in U.S.A. The 7300 Series LowBoy Plenum Heater is designed to fit jobs where the clear space between the ceiling and the floor above is as small as 11-3/4 inches. Product Specifications • 20 gauge galvanized cabinet. • Variable speed motor, factory set at maximum. Motor speed can be field adjusted to increase heat rise. • Acoustically insulated with 1” fiberglass. • Access panels on bottom of unit. • 24 Volt controls. • Air flow switch. • Terminal blocks. • Single point connection. • Dust tight control enclosure. • Filter rack on inlet with throw away filter. • Inlet and outlet screens and duct connection. • Automatic primary limit control. • Optional wall thermostat, unit thermostat or SSR control which proportionally regulates heat output. • Disconnect switch. Standard Models UPC# 686334 MODEL 618076 617543 606301 617642 534451 606455 609968 617734 617598 606363 534468 617697 534482 534499 608596 534505 617703 534529 608725 618106 608510 617536 608763 606189 F1G7305 H1G7305 G1G7305 F3G7305 H3G7305 P3G7305 F3E7310 H3G7310 P3G7310 F3E7310-2 H3G7310-2 P3G7310-2 H3G7312 P3G7312 F3E7312-2 H3G7312-2 P3G7312-2 H3G7315 P3G7315 F3E7315-2 H3G7315-2 P3G7315-2 P3G7318 P3G7318-2 KW CFM RANGE VOLTS/ TOTAL AMPS for MOTOR FULL LOAD AMPS STAGE MOTOR H.P. PHASE MOTOR & HEATER VOLTAGE for MOTOR ONLY 5 170-950 10 12 270-1500 15 18 SSR proportional control maximum: 45 Amps 208/1 240/1 277/1 208/3 240/3 480/3 208/3 240/3 480/3 208/3 240/3 480/3 240/3 480/3 208/3 240/3 480/3 240/3 480/3 208/3 240/3 480/3 480/3 480/3 26 22 20 15 14 8 32 26 14 32 26 14 32 17 41 32 17 39 21 49 39 21 25 25 277 2 277 2 120 277 277 120 277 277 277 277 120 277 277 277 277 120 277 277 277 277 4 2 2 4 2 2 3 3 8 3 3 3 3 8 3 3 3 3 WT. (LBS) 1 1 2 1 2 1 2 1 2 Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges. 1/4 163 2 Motors @ 1/4 HP Each 219 95 7300 Series Plenum Heater Product Dimensions 96 6" 6” Note: NOTE:Control panel access Control Panel access standard as shown. For panel as shown onStandard opposite side access specify For Panel on Opposite and orderAccess (FigureSpecify 5). Side Filter Rack Filter Rack Air Flow Air Flow L L 16 1/2" 16 1/2” G G 2” 2" 88 1/2" 1/2” F H F H Inlet Inlet ELECTRIC CONTROL IC TR PANEL EC OL EL TR Di A SD is Sccrrescehncahrgaer een ge A DIMENSIONS DIMENSIONS N CO nel Pa Disconnect Disconnect Switch Switch DISCHARGE DISCHARGE A B A 10" B 8" 5 & 10 KW 28, 75” 1” 6” 11.75” 45” 26” 8” 10” NOTE:Dimension C and G Will Vary Note: Dimension With C and Accessories. G will vary with accessories. 7300 SERIES 5 & 10 KW 7300 Series C C B B Air ow l Flow ir F And Order Figure 5. 1" Filter 1” Filter I Inn SSccrrleleetne t een W W C F C G 28.75" F 1" HG H L L WW 6" 11.75" 45" 26" 5 1/2” A 5 1/2" L L Note: IINle S n Sccrreeltn e t een Control panel access NOTE: standard as shown. For panel Control Panel Access on oppositeas sideShown access specify Standard For Panel(Figure On Opposite and order 5). Side Access Specify And Order Figure 5. 2” 2" H H G G F F 6" 6” A Filter Rack Filter Rack A Air Flow Air Flow ELECTRIC C CONTROL RI CT L LE TRO EPANEL ON L DiDi ScrScsrcsehcehaarrg een n gee Disconnect Disconnect Switch Switch B B (2) Filters (2) 1" 1” Filters w C C Flo AIR FLOW Air W W C NE PA 33 " 33” DIMENSIONS DIMENSIONS 8 8 1/2" 1/2” Inlet Inlet DISCHARGE W DISCHARGE A AB B 12,15 & 18 KW 28.75" 2" 6" 11.75" 45" 43" 8" 20" 12, 15, & 18 KW 28, 75” 2” 6” 11.75” 45” 43” 8” 20” NOTE:Dimension C and G Will Vary Note: Dimension With C and Accessories. G will vary with accessories. 7300 7300 Series SERIES C F GF C G HH LL W PD Series Packaged Duct Heater Standard Features 97 • Galvanized Steel Element Rack - Always 1” shorter than duct height and 1/2” shorter than duct width to allow insertion clearance • Galvanized Steel Compartment with 1/2” fiberglass Insulation & Hinged Cover • Door Interlock Disconnect Switch • Primary Automatic Reset Temp Limiting Control • Load Carrying Secondary over Temperature Protective Device(s) • Definite Purpose Magnetic Contactor(s) • Differential Pressure Fan Inter-lock Switch • Step Down Control Transformer / 24 Volt • Permanently Attached Wiring Diagram on Manufactured in U.S.A. inside of Terminal Compartment Cover Standard Models UPC 686334 MODEL NUMBER KW 617000 617017 617024 617031 617048 617055 617062 617079 617086 617093 617109 617116 617123 617130 617147 617154 617437 617321 617338 617345 617161 617178 617185 617192 617208 617215 617222 617239 617352 617369 617376 617383 617246 617253 617260 617277 617284 617291 617307 617314 617390 617406 617420 PD5-128-1 PD10-1810-1 PD15-1812-1 PD20-2012-1 PD25-2016-1 7PD2-128-1 7PD3.5-128-1 7PD5-128-1 8PD5-128-3 8PD10-1810-3 8PD15-1812-3 8PD15-1812-2-3 8PD20-2012-3 8PD25-2016-3 8PD30-2416-2-3 8PD30-2416-3 8PD35-2416-3 8PD40-2416-3 8PD45-3016-3 8PD50-3016-3 PD-128-3 PD10-1812-3 PD15-1812-1-3 PD15-1812-2-3 PD20-2012-3 PD25-2016-3 PD30-2416-2-3 PD30-2416-3-3 PD35-2416-3 PD40-2416-3 PD45-3016-3 PD50-3016-3 4PD5-128-3 4PD10-1810-3 4PD15-1812-3 4PD15-1812-2-3 4PD20-2012-3 4PD25-2016-3 4PD30-2416-2-3 4PD30-2416-3-3 4PD35-2416-3 4PD40-2416-3 4PD50-3016-3 5 10 15 20 25 2 3.5 5 5 10 15 15 20 25 30 30 35 40 45 50 5 10 15 15 19.9 25 30 30 35 40 45 49.8 5 10 15 15 20 25 30 30 35 39.9 50 DIMENSIONS POWER VOLTS/ PHASE DUCT WIDTH W DUCT HEIGHT A C E M 240-1 12 18 18 20 20 8 10 12 12 16 4.75 4.75 4.75 9.125 9.125 6.5 6.5 6.5 7.5 7.5 26 28 27 31 38 277-1 12 8 4.75 6.5 26 12 18 18 18 20 20 24 24 24 24 30 30 12 18 18 18 20 20 24 24 24 24 30 30 12 18 18 18 20 20 24 24 24 24 30 8 10 12 12 12 16 16 16 16 16 16 16 8 10 12 12 12 16 16 16 16 16 16 16 8 10 12 12 12 16 16 16 16 16 16 4.75 4.75 9.125 9.125 9.125 9.125 9.125 9.125 9.125 9.125 9.125 9.125 4.75 4.75 4.75 9.125 9.125 9.125 4.75 9.125 9.125 9.125 9.125 9.125 4.75 4.75 4.75 9.125 9.125 9.125 4.75 9.125 9.125 9.125 9.125 6.5 6.5 6.5 6.5 6.5 6.5 7.5 7.5 7.5 7.5 7.5 7.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 7.5 7.5 7.5 7.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 26 22 25 28 40 29 29 35 35 43 43 43 26 22 20 26 28 29 25 35 35 35 43 43 26 22 20 26 26 22 18 24 26 40 36 208-3 240-3 480-3 AMPS 20.9 41.7 62.5 83.3 104.2 7.2 12.6 18.1 13.9 27.8 41.7 41.7 55.6 69.5 83.4 83.4 97.3 111.2 125.1 139 12.1 24.1 36.2 36.2 47.9 60.2 72.3 72.3 84.3 96.3 108.4 120 6.1 12.1 18.1 18.1 24.1 30.1 36.2 36.2 42.2 48.1 60.2 CONTROL STEPS WT. (LBS.) 1 2 2 2 3 22 37 33 37 56 1 21 1 1 1 2 2 2 2 3 3 3 3 3 1 1 1 2 2 2 2 3 3 3 3 3 1 1 1 2 2 2 2 3 3 3 3 22 27 32 34 39 58 65 60 65 75 80 85 21 26 30 33 39 57 57 65 65 75 80 85 21 26 30 34 39 58 65 65 65 75 85 CHMS Series Finned Tubular Element Duct Heater • Available with Nema 4-4x-12 control panels • ABS type approved Manufactured in U.S.A. HL 1 Internal Duct Insulation 2 0 = None, 1 = 1” Thick, 2 = 2” Thick 24 Air Flow Direction Power Supply Volts NOTE: All blanks must be filled in when submitting an order to the factory. 3 Number of Control Stages 480 Control Volts 15KW 24, 120, 240, & 277 12H Kilowatts Duct Width Dimension 18W (over 55” heater must be flanged) Construction Options I F = Flange Mount, I = Insert Control Box Options 3 3 = Control Box on Heater, R = Remote CHMS Duct Height Dimension HOW TO DESIGNATE A MODEL: Phase • Integral or remote control panels 1 = Single Phase, 3 = Three Phase • Insert or Flanged construction Duct Heater Series 98 Finned tubular duct heaters provide many benefits to the customer. They provide slower heating and cooling for closer temperature regulation, electrical shock hazards are reduced, not as susceptible to shorting on the elements, are easily serviced, and better withstand physical abuse. MINIMUM HEATER SIZE 8” X 8” MAX KW 18.1 KW PER SQ. FT. Product Specifications General 1. Provide Series “CHMS” enclosed element electric duct heaters as manufactured and listed on schedule. 2. Power, voltage phase, control voltage, wattage, duct size, number of steps to be per schedule. 3. Heaters to be either slip-in or flanged type as called for on schedule. 4. All heaters to be ETL listed for zero clearance to combustible surfaces and bear ETL label. 5. All heaters shall meet the requirements of the National Electric Code. 6. Standard terminal box, recessed terminal box, standard control cabinet, remote control cabinet and element housing to be made of 18 gauge aluminized steel. Element Construction 1. All elements to be made of high quality alloy resistor wire, centered and permanently encased within highly compacted, rock-hard refractory material, surrounded by stainless steel sheath. All element terminations shall be threaded stainless steel type to insure a positive connection to leads. Terminal Box or Control Cabinet 1. Shall be constructed of 18 gauge Aluminized steel. All boxes to have a solid cover of the same gauge, complete with a piano type hinge on the longest dimension, tool operated latch and pull ring. Safety Controls 1. Primary over temperature protection shall be provided by built-in capillary type automatic reset thermal cutout. Capillary cutout shall be U.L. listed and of the fail safe type. 2. Secondary over temperature protection shall consist of a sufficient number of capillary type manual resets controlling back-up contactors. Capillary shall be the “fail safe” and “trip free” type. 3. All capillaries shall be installed in a protective Aluminum sheath. Sheath shall be etched and painted flat black to sense any over temperature condition the full length of heater face. 4. Over-current protection incorporating fuses must be provided for all heaters rated more than 48 Amperes, and factory installed, within the heater enclosure or provided as a separate assembly by the heater manufacturer. Heaters exceeding 48 Amperes total line current must be divided into sub-circuits of less than 48 Amperes and be protected at not more than 60 Amperes. Wiring Diagrams 1. A separate, complete and specific wiring diagram shall be permanently attached to each heater. Typical wiring diagrams are not acceptable. 2. Control and line terminals in each heater shall be marked to correspond to the wiring diagram. Air Flow Designations Guide for CHMS Series Duct Heaters HR: HL: VU: Left to Right (shown) Right to Left Vertical Up Control panel standard is extended upstream and same height as duct. This can be altered to accommodate available space. HF Series Open Coil Element Duct Heater Open coil duct heaters offer several advantages when used properly. They release heat directly into the air stream resulting in lower element temperatures, provide higher wattage per square foot of duct area, have low pressure drop due to high percentage of open area, are light weight, easily installed, and economical with quick delivery available. Standard Features • Galvanized steel control box with optional 1/2” insulation and hinged cover. • Primary and secondary over temperature protection. • De-energizing definite purpose contactors. • Differential pressure fan interlock. • 24 Volt control transformer. • Fusing over 48 Amps (per NEC). Manufactured in U.S.A. • Line terminal blocks. • Insert or Flange. • Integral or remote controls. • Standard NEMA 1 control. • Panel - available with NEMA 4-4x -12 panels as option integral or remote mounted. • Comply with NEC specification. Custom Specified Models 2 HR B G Air Flow Options Options 24 Stage Model 12H Control Volts Phase 10KW 12W Height HF Width 3 Kilowatts 480 Volts How to designate an HF Series open coil duct heater: Optional Controls & Features A: C: E: G: H3: J: Additional Stage Disconnecting Contactors Minimum fusing under 48 Amps Door Interlock Disconnect Switch SCR Control Three Phase Only Electronic Step Controller B: D: F: H1: I: “A” Alloy Element Wire PE Switch Flanged Construction SCR Control Single Phase Only NEMA 1 Dust Tight Control Box Air Flow Designations Guide for HF Series Duct Heaters HR: HL: VU: D: Left to Right (shown) Right to Left Vertical Up Vertical Down Control panel standard is extended upstream and same height as duct. This can be altered to accommodate available space. 99 HF Series Open Coil Element Duct Heater 100 Product Specifications General 1. Provide open coil, electric duct heaters, as manufactured and as listed in the schedule. 2. Power voltage and phase, control voltage, wattage, duct size, number of steps to be as per schedule. 3. Heaters to be either Slip-in or Flanged type as called for. 4. Three phase heaters shall have balanced three phase steps unless specified otherwise. 5. All heaters to be ETL listed for zero clearance to combustible surfaces and bear the ETL label. 6. All heaters shall meet the requirements of the latest National Electric Code. 7. Standard terminal box, recessed terminal box, standard control cabinet, remote control cabinet as well as element housing and racks all to be made of heavy gauge galvanized steel. (Aluminized steel optional). 8. All heating coils to be made of high grade Nickel/Chromium resistance wire and terminated by means of a loop of wire being sandwiched between stainless steel or Nickel plated washers and terminal hardware. All terminal hardware to be insulated from the heater by a two piece ceramic bushing. Element Assembly LINE KILOWATTS STAGE 1. To be of “Module” design with each module independently and easily removable VOLTS from the terminal box or control cabinet. 0.5-2.5 2. Each module to contain no more than 2 layers of element coils so that any one 2.6-5.0 coil may be replaced without disturbing others. 5.1-8.0 1 3. Element coils of each module to be on staggered spacing so that all coils per 8.1-11.0 module will be in the air stream, and shadowing (overheating) and/or blank areas eliminated. 11.1-15.0 15.1-19.0 Element Housing 19.1-24.0 1. To be of No. 18 gauge galvanized (aluminized) steel and to be of roll-formed 2 120 24.1-28.0 construction with multiple brakes and ribs for stiffness and rigidity. 208 28.1-30.0 240 Element Rack 30.1-34.0 1. To be constructed of No. 20 gauge galvanized (aluminized) steel and formed with 34.1-38.0 multiple brakes and ribs for stiffness and rigidity. 38.1-42.0 3 2. Ceramic coil supports to be floating, but contained and easily replaceable. 42.1-46.0 3. Ceramic coil insulators to be on staggered spacing per rack to eliminate blank areas in the air pattern thru the heaters, and provide uniform heating over the 46.1-51.6 entire cross section of the element. 51.7-55.0 4 4. Racks to support element coils on no more than 3 1/2” centers. 55.1-60.0 0.5-2.5 Terminal Box or Control Cabinet 1. Shall be constructed of heavy gauge galvanized steel (aluminized optional) 2.6-5.0 1 and in sizes up to 18” X 18” shall be No. 20 gauge and over to be No. 18 gauge. 5.1-8.0 277 All boxes to have a solid cover, of the same gauge, complete with a piano type 8.1-11.0 2 hinge on the longest side, approved tool operated latch and pull ring. Covers 11.1-15.0 over 48” long to be provided with two latches and pull rings. 0.5-2.5 2. Insulation consisting of 1/2” high density fiberglass will be provided, attached 2.6-5.0 to the cabinet, between the cabinet and the heating section. 1 5.1-8.0 3. Recessed terminal boxes used when ducts are internally insulated, or in air handling 8.1-11.1 units, to be of the same general construction as item 1 above. 11.2-15.0 Airflow Direction 15.1-19.0 2 Heaters will be interchangeable for mounting in a horizontal or vertical duct except when 19.1-24.0 position sensitive Mercury contactors, SCR’s or capillary type limit controls are built-in. In 24.1-28.0 480 these cases, airflow direction is as specified. 600 28.1-30.0 Safety Controls 30.1-34.0 1. Primary over temperature protection shall be provided by built in disc type 34.0-39.9 automatic reset thermal cutouts for duct heaters up to 10’ in width. Heaters over 40.0-44.0 3 40” high require two cutouts. Capillary type automatic reset thermal cutouts are 44.1-48.0 required for any heater 10’ wide or over. Capillary type controls to be UL listed 48.1-53.0 and of the “fail safe” type. 2. Secondary over temperature protection shall consist of a sufficient number of 53.1-56.0 load carrying replaceable disc controls to de-energize the elements if the 56.1-60.0 primary system fails. Note: Duct Heaters are available 3. Fuse link type heat limiters shall not be acceptable. All manual safety devices up to 1000KW. KW and stages shall be resetable thru the terminal box without removing the heater from the shown above are limited example duct. of available models. Wiring Diagrams 1. A separate, complete and specific wiring diagram shall be permanently attached to each heater. Typical wiring diagrams are not acceptable. 2. Control and line terminals in each heater shall be marked identical to the wiring diagram. MINIMUM DUCT Heater Controls SIZE 8” X 6” 1. All heater controls shall be factory mounted and wired. MAX KW 20 KW 2. Contactors shall be definite purpose type. No application type relays will be acceptable. PER SQ. FT. 3. All controls shall be furnished as specified. RFH Series Fan Coil Units 101 Manufactured in U.S.A. Discharge Grille RFH - W Model RFH - E Model Product Applications Perimeter Heating; Lobby Heating; Plenum Heating; Kitchen Make-up Air The fan pac offers the advantages of eliminating large and unsightly roof-top package equipment, and through the roof duct systems which require costly installations with greater horsepower requirements. Commercial or Industrial Unit Heaters Since the fan pac incorporates a centrifugal blower designed to operate at static pressures of up to .70 inches w.g., it is ideally suited for hanging in unused overhead spaces and forcing the warm air to occupied floor areas. Ductwork can also be utilized to circulate the heated or ventilated air over large areas that may not be in the vicinity of the fan pac. Product Construction, Options & Features Construction: • All units ETL Listed as a total package with electric heat or hot water coils. • Certified sound data by an independent testing laboratory. • Single point pneumatic pipe connections. • Each fan package is factory tested prior to shipment. • Fan package, electric heat and optional disconnect switch are factory wired as a package. • 20 gauge galvanized cabinet acoustically insulated 1” fiberglass. • 1” 4 lb. density core insulation is U.L. Listed and meets NFPA 90A standards. • Motors are single speed PSC with thermal over load protections, solid-state speed controller, and are permanently lubricated. • Access panels to the blower and motor are placed on both sides of the cabinet. • Fan and motor assembly is mounted on a special 16 Gauge pad and completely isolated from the casing with rubber vibration mounts. Options: • Factory wired disconnect switch. • Throw away filter. • Permanent filter. • Electric heat or hot water coils. • Sealed access panels. • 120 or 277 PSC motors. • Dust tight electric panel. • Acoustically lined discharge plenum or return air boot. Features: • The fan pac is a basic and very simple on/off operation for an application that requires a fan coil unit with electric or hot water heat and a static pressure duct system of up to .70 inches w.g. • The unit can be energized by electric controls (line voltage or low voltage) or by P.E. switches in conjunction with a pneumatic system. • SCR motor speed controller for continuous adjustable fan speed from minimum to maximum RPM. • Built-in line voltage thermostats are available for unit heater type applications. • Built-in control circuit transformers are available in 24V or 120V. • Hot water coils are one row 1/2” O.D., two row 5/8” O.D. copper tubes. Aluminum fins are standard with 10 FPI spacing. • Transformers for fan motors are NOT available. RFH Series Fan Coil Units Product Specifications The fan packages shall be factory assembled complete with electric heat/hot water coils. Factory mounted control panel shall provide all internal control and fan power wiring for a single point field connection. An optional factory mounted disconnect switch shall be furnished and prewired so as to disconnect all electrical components in the fan package. A single point field connection will be made at the disconnect switch. Fan package must be labeled and listed by a nationally recognized and locally accepted testing laboratory, such as ITS Intertek testing services. Fan packages must be tested for safety and in accordance with the latest National Electric Code. Casing shall be a minimum of 20 gauge galvanized steel and acoustically insulated with 1” fiberglass. The casing shall be Listed and meet NFPA and NBFU 90A requirements. Blower casing shall be constructed of heavy gauge steel and baked enamel finish. Fan wheel shall be forward curved centrifugal type, dynamically balanced and be driven by direct drive, single speed permanent split capacitor motors. Motors shall be single phase, 1050 RPM. An electronic motor speed control shall be provided to allow continuously adjustable fan speed from minimum to maximum and shall incorporate a minimum voltage stop to insure motor cannot operate in stall mode. Fan assembly shall be mounted on a 16 gauge steel sub-base, but shall be internally isolated with rubber-in-shear isolators to prevent vibration transfer to the sub-base. Motors shall also be isolated with rubber-in-shear isolators between the motor mounting legs and the blower casing. Fan motor assembly shall be accessible through access panels from both sides and rear of cabinet (bottom and top access panels are not acceptable). Access panels shall have gasket to prevent leakage and vibration transmission. An electric heater (hot water optional) shall be part of the total listed package and shall be controlled by pneumatic, electric controls enclosed in a NEMA-1 enclosure on the side of the cabinet. The panel shall be gasket sealed to prevent air leakage. Heater shall be the requested available voltage and phase. Each fan package will be factory tested prior to shipment and certified as such. Each fan shall have an optional throw-away or permanent filter, and an optional acoustically lined discharge plenum or return air boot. Custom Specified Models Electric Heat RFH E HEAT TYPE SIZE HEAT CAPACITY OPTIONS HOW TO DESIGNATE A MODEL: SERIES 102 500 5 KW Disconnect Switch Hot Water Heat RFH W 500 12.6 MBH Inlet Attenuator Washable Filter Totally Enclosed Motor Minimum CFM’S Based On KW KW 5 7 9 10 CFM 400 500 600 700 KW 11 13 14 15 17 CFM 800 900 1000 1100 1200 KW 18 20 21 23 24 CFM 1300 1400 1500 1600 1700 KW 26 27 28.5 30 CFM 1800 1900 2000 2100 RFH Series Fan Coil Units Product Configurations 103 HOT WATER COIL LEFT HAND CONNECTION. STANDARD NO HEAT UNIT RFH RFH-W AIR FLOW AIR FLOW FIG-1 HOT WATER COIL RIGHT HAND CONNECTION ELECTRIC HEAT STANDARD UNIT AIR FLOW FIG-2 RFH-W RFH-E AIR FLOW FIG-4 FIG-3 NOTE:DRAWING SHOWS ELECTRIC HEAT ALSO AVAILABLE FOR NO HEAT, AND HOT WATER COILS. RFH AIR FLOW FIG-5 RFH-E Series Fan Coil Units 104 L B AIR INLET 5-1/2" STANDARD 2" A H R AI OW FL Dimensions (Inches) Model W Discharge A B L W H 300 12 14 28 14 8 500 14 18 36 18 8 750 18 18 36 18 10 1500 18 22 36 22 10 1800 18 26 36 26 10 2000 18 26 36 26 10 3000 18 44 36 44 10 4000 18 52 36 52 10 FAN PAC-Electric Heat MFH PERFORMANCE DATA MODEL MOTOR H.P. MOTOR AMPS FULL LOAD AMPS 115V 277V 300 1 @ 1/15 2.90 1.00 500 1 @ 1/6 3.60 1.10 750 1 @ 1/4 5.30 1.70 1500 1 @1/2 8.30 2.50 1800 1 @ 1/2 9.70 3.10 2000 1 @ 3/4 11.00 4.30 3000 2 @ 1/2 19.40 6.30 4000 2 @ 3/4 22.00 8.60 MFH-E ELECTRIC HEAT EXTERNAL STATIC PRESSURE (in. H20) MOTOR SPEED CONTR. .1 CFM .2 CFM .3 CFM .4 CFM MAX 270 245 225 180 MIN 95 85 80 70 MAX 740 700 640 590 530 490 450 MIN 290 275 250 230 210 200 190 MAX 1390 1370 1350 1270 1230 1130 1040 MIN 450 440 430 420 410 405 400 MAX 1825 1790 1740 1660 1570 1450 1340 MIN 820 790 760 675 590 515 440 MAX 2120 2080 2040 1940 1850 1750 1670 MIN 850 840 820 810 790 740 630 MAX 2230 2160 2100 2040 1960 1860 1760 MIN 1200 1120 1040 950 860 750 640 MAX 3160 3040 2920 2790 2600 2440 2240 MIN 1840 1800 1760 1720 1640 1560 1460 MAX 4150 4050 3950 3830 3650 3250 3000 MIN 2200 2180 2160 2130 2080 2000 1900 *See minimum CFM chart for all electric coil selections. 208V and 240V units use 277V rated motors - F.L.A. on 208V and 240V units same as 277V. For fan curve data consult factory .5 CFM .6 CFM .7 CFM Below 50 CFM RFH-DG Series Fan Coil Units 105 L B AIR INLET 5 1/2" STANDARD 2" Basic Weight (no options) Model 300 500 750 1500 1800 2000 3000 4000 Model lbs. 95 115 138 160 175 198 275 315 DISCHARGE GRILLE R AI OW FL W FAN PAC-With Discharge Grille Dimensions (Inches) A B L H 500 14 18 36 10 750 18 18 36 12 1500 18 22 36 12 1800 18 26 36 12 2000 18 26 36 12 3000 18 44 36 12 4000 18 52 36 12 MFH PERFORMANCE DATA MODEL MOTOR H.P. MOTOR AMPS FULL LOAD AMPS 115V 277V 300 1 @ 1/15 2.90 1.00 500 1 @ 1/6 3.60 1.10 750 1 @ 1/4 5.30 1.70 1500 1 @1/2 8.30 2.50 1800 1 @ 1/2 9.70 3.10 2000 3000 4000 1 @ 3/4 2 @ 1/2 2 @ 3/4 A H 11.00 19.40 22.00 4.30 6.30 8.60 MFH-DG ELECTRIC HEAT DISCHARGE GRILL EXTERNAL STATIC PRESSURE (in. H20) MOTOR SPEED CONTR. .1 CFM .2 CFM .3 CFM .4 CFM MAX 220 195 175 130 MIN 95 85 80 70 MAX 640 600 540 490 430 390 350 MIN 290 275 250 230 210 200 190 MAX 1290 1270 1250 1170 1130 1030 940 MIN 450 440 430 420 410 405 400 MAX 1725 1690 1640 1560 1470 1350 1240 MIN 820 790 760 675 590 515 440 MAX 2020 1980 1940 1840 1750 1650 1570 MIN 850 840 820 810 790 740 630 MAX 2130 2060 2000 1940 1860 1760 1660 .5 CFM .6 CFM .7 CFM Below 50 CFM MIN 1200 1120 1040 950 860 750 640 MAX 3060 2940 2820 2960 2500 2340 2140 MIN 1840 1800 1760 1720 1640 1560 1460 MAX 4050 3950 3850 3730 3550 3150 2900 MIN 2200 2180 2160 2130 2080 2000 1900 *See minimum CFM chart for all electric coil selections. 208V and 240V units use 277V rated motors - F.L.A. on 208V and 240V units same as 277V. For fan curve data consult factory RFH-W Series Fan Coil Units 106 DIMENSIONS DISCHARGE W H A B L 300 12" 14" 28" 14" 12" 500 750 1500 14" 18" 18" 18" 18" 22" 36" 36" 36" 18" 18" 22" 14" 18" 18" 1800 18" 26" 36" 26" 18" 2000 18" 26" 36" 26" 18" MODEL 1"-4 SIDES FILTER SIZE = AxB B L AIR INLET 5 1/2" STANDARD A H ACCESS DOOR ON BOTH SIDES OF UNIT ELECTRIC CONTROL PANEL COIL CONNECTION 1-ROW 1/2" O.D. NOM. 2-ROW 5/8" O.D. NOM. W AIR FLOW FAN PAC WITH HOT WATER HEAT DATE 6-29-01 Altitude Correction Factors Alt. Heat Ft. Factor 0 1.00 2000 0.94 3000 0.90 4000 0.87 5000 0.84 6000 0.81 7000 0.78 Entering Air °F HEATING CAPACITY CORRECTION FACTORS (AT VARIOUS WATER & AIR ENTERING TEMPERATURES) Entering Water Temperatures °F 100° 110° 120° 130° 140° 150° 160° 170° 180° 190° 200° 50° .455 .545 .635 .727 .818 .909 1.000 1.091 1.182 1.273 1.364 55° .409 .500 .591 .682 .773 .864 .955 1.045 1.136 1.227 1.318 60° .363 .455 .545 .636 .727 .818 .909 1.000 1.091 1.182 1.273 65° .318 .409 .500 .691 .682 .773 .864 .955 1.045 1.136 1.227 70° .272 .363 .455 .545 .636 .727 .818 .909 1.000 1.091 1.182 75° .227 .318 .409 .500 .691 .662 .773 .864 .955 1.045 1.136 80° .182 .272 .363 .455 .545 .636 .727 .818 .909 1.000 1.091 RFH-W Series Fan Coil Units Hot Water Reheat Capacity SIZE COIL ROWS GPM 0.5 1.0 1.5 2.0 3.0 4.0 5.0 300 1 0.5 1.0 1.5 2.0 3.0 4.0 5.0 2 SIZE COIL ROWS 0.5 1.0 1.5 2.0 3.0 4.0 5.0 500 0.5 1.0 1.5 2.0 3.0 4.0 5.0 2 COIL ROWS 0.5 1.0 1.5 2.0 3.0 4.0 5.0 750 0.5 1.0 1.5 2.0 3.0 4.0 5.0 2 COIL ROWS 1500 1 2 S.P. DROP S.P. DROP S.P. DROP GPM 0.5 1.0 1.5 2.0 3.0 4.0 5.0 .09 .30 .50 1.0 2.0 3.0 5.0 .02 .09 .15 .30 .60 1.0 1.5 S.P. DROP H20 PD (TL) S.P. DROP 0.3 1.0 1.9 3.2 6.5 10.8 16.0 S.P. DROP 1.0 0.3 1.5 0.6 2.0 1.0 4.0 3.2 6.0 6.5 8.0 10.8 10.0 16.0 300 REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 350 400 500 REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 600 700 0.016 9.8 11.8 12.7 13.2 13.8 14.1 14.3 0.032 14.2 18.2 20.1 21.1 22.3 23.0 23.4 0.2 0.6 1.3 2.1 4.3 7.1 10.4 0.1 0.2 0.5 0.8 1.7 2.8 4.1 H20 PD (TL) S.P. DROP 100 REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 150 200 .01 4.0 4.7 5.0 5.1 5.2 5.3 5.3 .02 6.4 7.4 7.8 8.0 8.1 8.2 8.3 H20 PD (TL) GPM 1 SIZE S.P. DROP GPM 1 SIZE H20 PD (TL) 0.025 12.7 16.2 17.9 18.8 19.8 20.4 20.8 .049 17.8 24.7 28.2 30.3 32.7 34.0 34.9 0.2 0.8 1.7 2.8 5.6 9.3 13.7 0.1 0.2 0.5 0.8 1.7 2.8 4.1 1200 0.079 16.6 23.5 27.1 29.3 31.8 33.2 34.2 0.159 34.8 42.4 47.4 57.4 61.6 64.0 65.5 1300 0.091 16.9 24.0 27.8 30.1 32.8 34.3 35.3 0.183 35.4 43.4 48.8 59.4 63.9 66.5 68.1 .02 4.8 5.7 6.0 6.2 6.3 6.4 6.5 .04 7.8 9.2 9.8 10.3 10.7 10.9 11.1 0.021 10.3 12.6 13.6 14.2 14.9 15.2 15.4 0.042 14.9 19.6 21.7 23.0 24.5 25.3 25.8 .06 5.9 7.0 7.4 7.7 8.0 8.2 8.3 .12 9.3 11.7 12.5 13.3 13.9 14.5 14.8 450 0.026 10.7 13.3 14.4 15.1 15.8 16.2 16.5 0.053 15.6 20.7 23.2 24.7 26.4 27.3 27.9 0.034 13.3 17.3 19.2 20.3 21.5 22.2 22.6 .068 18.6 26.5 30.5 33.0 36.9 37.6 38.7 0.033 11.1 13.9 15.2 15.9 16.7 17.1 17.4 0.065 16.1 21.7 24.5 26.2 28.1 29.2 29.9 800 0.045 13.8 18.2 20.3 21.6 23.0 23.8 24.3 .090 19.2 27.9 32.5 35.4 38.8 40.7 42.0 REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 1400 1500 0.104 17.1 24.5 28.4 30.8 33.7 35.3 36.4 0.209 36.0 44.4 50.0 61.3 66.2 68.9 70.7 250 .04 5.5 6.3 6.7 7.0 7.2 7.3 7.4 .08 8.7 10.8 11.2 12.0 12.4 12.8 13.1 0.118 17.2 24.9 29.0 31.5 34.5 36.2 37.4 0.263 36.5 45.2 51.1 63.0 68.2 71.2 73.1 0.057 14.2 19.0 21.3 22.7 24.3 25.2 25.7 .114 19.7 29.1 34.2 37.4 41.3 43.5 45.0 1600 0.132 17.4 25.3 29.6 32.3 35.3 37.1 38.3 0.265 37.0 46.0 52.2 64.7 70.2 73.3 75.3 107 RFH-W Series Fan Coil Units Hot Water Reheat Capacity SIZE COIL ROWS 1800 1 2 SIZE COIL ROWS 2000 1 2 SIZE COIL ROWS 3000 1 2 SIZE COIL ROWS 1 4000 108 2 GPM H20 PD (TL) S.P. DROP 1.0 1.5 2.0 2.5 3.0 4.0 5.0 S.P. DROP 1.0 1.5 2.0 4.0 6.0 8.0 10.0 GPM 1.0 1.5 2.0 2.5 3.0 4.0 5.0 1.0 1.5 2.0 4.0 6.0 8.0 10.0 GPM 1.0 1.5 2.0 2.5 3.0 4.0 5.0 1.0 1.5 2.0 4.0 6.0 8.0 10.0 GPM 1.0 1.5 2.0 3.0 4.0 5.0 7.0 1.0 3.0 5.0 6.0 8.0 10.0 12.0 1500 0.086 26.7 31.4 34.3 36.3 37.7 40 41.0 0.171 38.4 48.0 54.5 67.8 73.3 76.9 79.0 1.1 2.2 3.7 5.4 7.5 12.4 18.3 0.3 0.7 1.1 3.7 7.5 12.4 18.3 H20 PD (TL) S.P. DROP S.P. DROP S.P. DROP 0.2 0.3 0.5 1.2 3.0 7.0 10.0 H20 PD (TL) S.P. DROP S.P. DROP 0.3 0.6 1.0 2.0 3.4 5.0 9.0 0.2 1.5 3.2 4.5 7.5 12.0 16.5 0.118 27.9 33.1 36.4 38.6 40.3 42.5 44.0 0.237 39.7 50.3 57.7 73.0 79.9 83.8 86.3 0.3 0.7 1.1 3.7 7.5 12.4 18.3 0.3 0.5 0.9 1.5 2.0 3.0 4.5 0.096 27.2 32.0 35.0 37.1 38.6 40.7 42.0 0.192 38.9 48.8 55.7 69.7 75.8 79.3 81.6 1800 1.1 2.2 3.7 5.4 7.5 12.4 18.3 H20 PD (TL) S.P. DROP REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 1600 1700 1800 0.107 27.6 32.6 35.7 37.9 39.5 41.6 43.1 0.214 39.3 49.6 56.7 71.4 77.9 81.6 84.0 0.118 27.9 33.1 36.4 38.6 40.3 42.5 44.0 0.237 39.7 50.3 57.7 73.0 79.9 83.8 86.3 REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 1900 2000 0.130 28.3 33.6 37.0 39.9 41.0 43.4 44.9 0.261 40.1 51.0 58.6 74.6 81.8 85.9 88.5 0.143 28.6 34.1 37.6 40.0 41.8 44.2 45.8 0.286 40.4 51.6 59.5 76.0 83.5 87.8 90.6 1900 0.130 28.3 33.6 37.0 39.3 41.0 43.4 44.9 0.261 40.1 51.0 58.6 74.6 81.8 85.9 88.5 2100 0.156 28.9 34.5 38.1 40.6 42.4 45.0 46.7 0.312 40.8 52.2 60.3 77.4 85.3 89.7 92.7 2000 REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 2200 2400 2600 3000 2500 0.06 35.5 45.1 52.0 60.4 64.7 69.1 74.0 0.11 46.2 93.5 113.9 120.0 129.1 135.0 138.2 REHEAT CAPACITY (MBH)@CFM PRIMARY CFM @ HEATING 2900 3100 3500 0.075 0.09 0.11 36.6 36.9 37.6 46.8 47.4 48.2 54.0 54.8 56.1 63.2 64.4 66.8 68.1 69.7 72.2 72.9 74.4 76.0 78.0 80.0 82.0 0.15 0.185 0.21 46.8 47.2 48.1 96.8 100.0 103.2 115.0 12.1 128.0 123.0 131.6 137.1 130.0 141.8 148.9 139.0 147.6 156.2 143.0 154.1 162.1 3900 0.14 38.0 49.0 57.8 68.3 74.2 80.2 87.0 0.265 49.0 105.8 123.7 143.0 155.0 163.8 170.2 0.05 32.6 40.2 45.5 48.2 52.0 55.3 58.5 0.10 44.0 53.9 63.8 91.6 102.4 108.6 112.2 0.06 33.1 41.3 46.8 50.3 53.8 57.9 60.8 0.12 44.5 56.1 67.6 94.1 107.2 113.9 118.6 0.07 33.9 42.0 48.0 51.8 55.5 59.1 62.9 0.14 45.8 56.9 68.5 97.4 110.1 118.7 123.1 0.09 34.1 43.1 49.2 53.2 57.2 60.9 64.8 0.18 46.2 59.7 72.4 101.2 114.6 122.8 128.0 0.11 35.1 44.1 50.8 54.9 59.1 63.1 68.0 0.22 47.1 61.2 75.7 104.2 121.3 130.4 136.0 Product Index Listing Page Model Page Model Page Model Page 8510 28 63016489 69 222-A30-THSS-208V 68 305EX32 39 8512 28 A1560 80 222-A30-THSS-240V 68 305EX8 39 8513 28 DBTS IECR 62 222-A30-THSS-277V 68 30R 34 8514 28 170-TS 79 222-A30-THSS-480V 68 30R2 34 8515 28 178 TMC 79 222-A60-TH-208V 68 30R7 34 8516 28 188 TASA 79 222-A60-TH-240V 68 30R8 34 8517 28 18D-2-30CF (Enclosed) 74 222-A60-TH-277V 68 32T1 46 8518 28 18D-2-30CF (Open) 74 222-A60-TH-480V 68 32T2 46 8519 28 18D-2-80CF (Enclosed) 74 222-A60-THSS-208V 68 3310EX33R 45 8520 28 198 TMC 79 222-A60-THSS-240V 68 3310EX33WR 45 8522 28 21RCH2 35 222-A60-THSS-277V 68 3320EX16 40 8523 28 21RCH3 35 222-A60-THSS-480V 68 3320EX33 40 8524 28 21RCH4 35 223-30-THSS-208V 69 3380EX33 34 8525 28 21RCH5 35 223-30-THSS-240V 69 3420EX16 43 8526 28 21SCH2 36 223-30-THSS-277V 69 3420EX34 43 8527 28 21SCH3 36 223-30-THSS-480V 69 3420EX8 43 8528 28 21SCH4 36 223-60-THSS-208V 69 342-30-TH-208V 68 8529 28 21SCH5 36 223-60-THSS-240V 69 342-30-TH-240V 68 8530 28 21WD10T01 11 223-60-THSS-277V 69 342-30-TH-480V 68 8532 28 21WD15T01 11 223-60-THSS-480V 69 342-30-THSS-208V 68 8533 28 21WD3T01 11 223-90-THSS-208V 69 342-30-THSS-240V 68 8534 28 21WD5T01 11 223-90-THSS-240V 69 342-30-THSS-480V 68 8535 28 21WD7T01 11 223-90-THSS-277V 69 342-60-TH-208V 68 8536 28 222-30-TH-208V 68 223-90-THSS-480V 69 342-60-TH-240V 68 8537 28 222-30-TH-240V 68 22WD10T01 11 342-60-TH-480V 68 8538 28 222-30-TH-277V 68 22WD15T01 11 342-60-THSS-208V 68 8539 28 222-30-TH-480V 68 22WD3T01 11 342-60-THSS-240V 68 9128 56 222-30-THSS-208V 68 22WD5T01 11 342-60-THSS-480V 68 9136 56 222-30-THSS-240V 68 22WD7T01 11 342-90-TH-208V 68 9148 56 222-30-THSS-277V 68 23RCH2 35 342-90-TH-240V 68 9160 56 222-30-THSS-480V 68 23RCH3 35 342-90-TH-480V 68 9172 56 222-60-TH-208V 68 23RCH4 35 342-90-THSS-208V 68 9184 56 222-60-TH-240V 68 23RCH5 35 342-90-THSS-240V 68 9196 56 222-60-TH-277V 68 23SCH2 36 342-90-THSS-480V 68 9328 58 222-60-TH-480V 68 23SCH3 36 342-A30-TH-208V 68 9336 58 222-60-THSS-208V 68 23SCH4 36 342-A30-TH-240V 68 9348 58 222-60-THSS-240V 68 23SCH5 36 342-A30-TH-480V 68 9360 58 222-60-THSS-277V 68 23WD20T01 11 342-A30-THSS-208V 68 9372 58 222-60-THSS-480V 68 23WD25T01 11 342-A30-THSS-240V 68 9384 58 222-90-TH-208V 68 23WD30T01 11 342-A30-THSS-480V 68 9396 58 222-90-TH-240V 68 24A01G-3 87 342-A60-TH-208V 68 91108 56 222-90-TH-277V 68 24A05A-1 87 342-A60-TH-240V 68 91120 56 222-90-TH-480V 68 24A05E-1 87 342-A60-TH-480V 68 93108 58 222-90-THSS-208V 68 24A06G-1 87 342-A60-THSS-208V 68 93120 58 222-90-THSS-240V 68 303EX16RW 34 342-A60-THSS-240V 68 31939009 69 222-90-THSS-277V 68 303EX16RW 46 342-A60-THSS-480V 68 31940009 69 222-90-THSS-480V 68 303EX32RW 34 343-30-THSS-208V 69 31941009 69 222-A30-TH-208V 68 303EX32RW 46 343-30-THSS-240V 69 63016209 69 222-A30-TH-240V 68 303EX8RW 34 343-30-THSS-480V 69 63016249 69 222-A30-TH-277V 68 303EX8RW 46 343-60-THSS-208V 69 63016279 69 222-A30-TH-480V 68 305EX16 39 343-60-THSS-240V 69 1 INDEX Model Product Index Listing Model 343-60-THSS-480V INDEX 2 Page Model Page Model Page Model Page 69 41SCH5 36 483 TM 79 641-70271 73 48T2 48 641-70281 73 343-90-THSS-208V 69 4300EX16 47 343-90-THSS-240V 69 4300EX16W 47 4PD10-1018-3 97 641-70321 73 343-90-THSS-480V 69 4300EX16W 48 4PD15-1218-2-3 97 671-3454 73 3450EX16 43 4300EX32 47 4PD15-1218-3 97 671-3492* 73 3450EX34 43 4300EX32W 47 4PD20-1220-3 97 671-3784 73 97 3450EX8 43 4300EX32W 48 4PD25-1620-3 671-3785 73 3900AC 51 4300EX8 47 4PD30-1624-2-3 97 671-3786 73 3900ACC 51 4300EX8W 47 4PD30-1624-3-3 97 671-5018 73 3900-CS 51 4300EX8W 48 4PD35-1624-3 97 671-5056 73 3900-CSC 51 4300P 47 4PD40-1624-3 97 671-5057 73 97 3900DS 51 4300PB 40 4PD50-1630-3 671-5058 73 3900DSC 51 4300PW 47 4PD5-812-3 97 671-5059 73 3900-ICS 51 4300PW 48 630-05129 73 671-5060 73 3900-ICSC 51 43RCH2A1 35 630-10209 73 671-5061 73 3900-OCS 51 43RCH4A1 35 630-10249 73 71RCH2 35 3900-OCSC 51 43RCH5A1 35 630-16209 73 71RCH3 35 3900REC 51 43RCHA1 35 630-16249 73 71RCH4 35 3900RECC 51 43SCH4 36 630-16279 73 71RCH5 35 3900T1 51 43SCH5 36 630-16489 73 71SCH2 36 3900T1C 51 43SCHA1 36 630-25209 73 71SCH3 36 3900T2 51 43SCHA1 36 630-25249 73 71SCH4 36 3900T2C 51 43T 47 630-25279 73 71SCH5 36 3900WW120 51 43T 48 630-25489 73 71WD10T01 11 73 3900WW28 51 43T2 47 631-16249 71WD3T01 11 3900WW36 51 43WD10T01 11 632-1620 69 71WD5T01 11 3900WW48 51 43WD15T01 11 632-1624 69 71WD7T01 11 3900WW60 51 43WD20T01 11 632-2548 69 7PD2-812-1 97 3900WW72 51 43WD25T01 11 6333D053834B30D0F1 25 7PD3.5-812-1 97 3900WW96 51 43WD30T01 11 6333D054134B30D0F1 25 7PD5-812-1 97 39BS120 51 43WD3T01 11 6333D103834B30D0F1 25 81RCH2 35 39BS120C 51 43WD40T01 11 6333D104134B30D0F1 25 81RCH3 35 39BS28 51 43WD48T01 11 641-35611 73 81RCH4 35 39BS28C 51 43WD5T01 11 641-35621 73 81RCH5 35 39BS36 51 43WD7T01 11 641-35631 73 81SCH2 36 39BS36C 51 4400EX16 40 641-35641 73 81SCH3 36 39BS48 51 4400EX32 40 641-35661 73 81SCH4 36 73 39BS48C 51 4400EX8 40 641-36051 81SCH5 36 39BS60 51 462-30-TH-480V 68 641-36061 73 81WD10T01 11 39BS60C 51 462-30-THSS-480V 68 641-36071 73 81WD15T01 11 39BS72 51 462-60-TH-480V 68 641-37211 73 81WD3T01 11 39BS72C 51 462-60-THSS-480V 68 641-50011 73 81WD5T01 11 39BS96 51 462-90-TH-480V 68 641-50021 73 81WD7T01 11 39BS96C 51 462-90-THSS-480V 68 641-70001 73 82WD10T01 11 41RCH2A1 35 462-A30-TH-480V 68 641-70011 73 82WD15T01 11 41RCH3A1 35 462-A30-THSS-480V 68 641-70021 73 82WD3T01 11 41RCH4A1 35 462-A60-TH-480V 68 641-70031 73 82WD5T01 11 41RCH5A1 35 462-A60-THSS-480V 68 641-70041 73 82WD7T01 11 41SCH2 36 463-30-THSS-480V 69 641-70241 73 83RCH2 35 41SCH3 36 463-60-THSS-480V 69 641-70251 73 83RCH3 35 69 641-70261 73 83RCH4 35 41SCH4 36 463-90-THSS-480V Product Index Listing Model Page 83RCH5 35 A5150 83SCH2 36 A5175 83SCH3 36 A5520/UHB 83SCH4 36 A6176 83SCH5 36 83WD20T01 83WD25T01 Model Page Model Page 15 AFH8330 41 BBS040C 55 18 AFH8340T 41 BBS048A 55 10 AFH8350T 41 BBS048AW 55 17 AG3401-24 36 BBS048C 55 A6176 86 AG3402-24 36 BBS060A 55 11 AD5120 15 AG3403-24 36 BBS060AW 55 11 AD5150 15 AH3401-24 36 BBS060C 55 83WD30T01 11 AD5150 15 AH3402-24 36 BBS072A 55 8PD10-1018-3 97 AD5175 15 AH3403-24 36 BBS072AW 55 8PD15-1218-2-3 97 AET5DWS 83 APS-3C 74 BBS072C 55 8PD15-1218-3 97 AET5SWS 83 ASHDB ECL 63 BBS084A 55 8PD20-1220-3 97 AF3401-24 36 ASHDB ECR 63 BBS084AW 55 8PD25-1620-3 97 AF3402-24 36 ASHDB IC 63 BBS084C 55 8PD30-1624-2-3 97 AF3403-24 36 ASHDB OC 63 BBS096A 55 8PD30-1624-3 97 AFC2120T 41 ASHDB SP 63 BBS096AW 55 8PD35-1624-3 97 AFC2130T 41 ASHDB WT 63 BBS096C 55 8PD40-1624-3 97 AFC2140T 41 ASHDB-10 63 BBS120A 55 8PD45-1630-3 97 AFC2150T 41 ASHDB-2 63 BBS120AW 55 8PD50-1630-3 97 AFC2320 41 ASHDB-3 63 BBS120C 55 8PD5-812-3 97 AFC2330 41 ASHDB-4 63 BDR115 55 9100EC 58 AFC2340T 41 ASHDB-5 63 BDR115B 55 9100IC 56 AFC2350T 41 ASHDB-6 63 BDR115W 55 9100OC 56 AFC7120T 41 ASHDB-7 63 BOX 3310 40 91BS012 56 AFC7130T 41 ASHDB-8 63 BOX 3420 41 91BS024 56 AFC7140T 41 ASHDB-8/20-1000BS 63 BOX 3450 41 91BS036 56 AFC7150T 41 ASHDB-8/20-100BS 63 BOX3310 34 91BS048 56 AFC8120T 41 ASHDB-8/20-200BS 63 BOX3310 45 91BS060 56 AFC8130T 41 ASHDB-8/20-300BS 63 C1025 19 91BS072 56 AFC8140T 41 ASHDB-8/20-400BS 63 C1-TD 8 91BS084 56 AFC8150T 41 ASHDB-8/20-500BS 63 C1-TDP 8 91BS096 56 AFC8330 41 ASHDB-8/20-600BS 63 CB ECL 63 91BS108 56 AFC8340T 41 ASHDB-8/20-700BS 63 CB ECR 63 91BS120 56 AFC8350T 41 ASHDB-8/20-800BS 63 CB IC 63 9300EC 58 AFC8380 41 ASHDB-8/20-900BS 63 CB MF 63 9300IC 58 AFH2120T 41 ASHDB-9 63 CB OC 63 9300OC 58 AFH2130T 41 ATR 60 CB SP 63 93BS012 58 AFH2140T 41 B5105 15 CB WT 63 93BS024 58 AFH2150T 41 B51100 18 CB-10 63 93BS036 58 AFH2320 41 B5150 15 CB-1000BS 63 93BS048 58 AFH2330 41 B5175 18 CB-100BS 63 93BS060 58 AFH2340T 41 BBS024A 55 CB-2 63 93BS072 58 AFH2350T 41 BBS024AW 55 CB-200BS 63 93BS084 58 AFH7120T 41 BBS024C 55 CB-3 63 93BS096 58 AFH7130T 41 BBS028A 55 CB-300BS 63 93BS108 58 AFH7140T 41 BBS028AW 55 CB-4 63 93BS120 58 AFH7150T 41 BBS028C 55 CB-400BS 63 A1600 22 AFH8120T 41 BBS036A 55 CB-5 63 A1601 22 AFH8130T 41 BBS036AW 55 CB-500BS 63 A5105 15 AFH8140T 41 BBS036C 55 CB-6 63 A51100 18 AFH8150T 41 BBS040A 55 CB-600BS 63 A5120 15 AFH8320 41 BBS040AW 55 CB-7 63 3 INDEX Page Model Product Index Listing Model INDEX 4 Page Model Page Model Page Model Page CB-700BS 63 CH-6 65 CV100YX 38 DBCT/DBCF-1000BS 61 CB-8 63 CH-620-3C 64 CV11012X 38 DBCT/DBCF-100BS 61 CB-800BS 63 CH-624-3C 64 CV11022Xi 38 DBCT/DBCF-200BS 61 CB-9 63 CH-627-3C 64 CV11027X 38 DBCT/DBCF-300BS 61 CB-900BS 63 CH-6424-1C 77 CV110X 38 DBCT/DBCF-400BS 61 CF36 82 CH-648-3C 64 CV110Xi 38 DBCT/DBCF-500BS 61 CF48 82 CH-657-3C 64 CV110YX 38 DBCT/DBCF-600BS 61 CF60 82 CHWG-222 69 CV12512X 38 DBCT/DBCF-700BS 61 CFHD36 82 CHWG-223 69 CV12522Xi 38 DBCT/DBCF-800BS 61 CFHD48 82 CHWG-342 69 CV12527X 38 DBCT/DBCF-900BS 61 CFHD60 82 CHWG-343 69 CV125X 38 DBCT-10/DBCF-10 61 CH-13 65 CHWG-462 69 CV125Xi 38 DBCT-2/DBCF-2 61 CH-13 65 CHWG-463 69 CV125YX 38 DBCT-3/DBCF-3 61 CH-13 65 CIT-1 74 CV4512X 38 DBCT-4/DBCF-4 61 CH-13 65 CKTD110 84 CV4522Xi 38 DBCT-5/DBCF-5 61 CH-1320-3B 64 CP122 37 CV4527X 38 DBCT-6/DBCF-6 61 CH-1324-3B 64 CP122i 37 CV45X 38 DBCT-7/DBCF-7 61 CH-1327-3B 64 CP123 37 CV45Xi 38 DBCT-8/DBCF-8 61 CH-1348-3B 64 CP123i 37 CV45YX 38 DBCT-9/DBCF-9 61 CH-1357-3B 64 CP125 37 CV6012X 38 DBF/DBT ECL 61 CH-2 65 CP125i 37 CV6022Xi 38 DBF/DBT ECR 61 CH-2 65 CP127 37 CV6027X 38 DBF/DBT IC 61 CH-212-1C 64 CP127i 37 CV60X 38 DBF/DBT IECL 61 CH-220-1C 64 CP2202i 37 CV60Xi 38 DBF/DBT IECR 61 CH-2212-1C 77 CP2203i 37 CV60YX 38 DBF/DBT IF 61 CH-224-1C 64 CP2205i 37 CV7512X 38 DBF/DBT MF 61 CH-227-1C 64 CP2207i 37 CV7522Xi 38 DBF/DBT OC 61 CH-248-1C 64 CP702 37 CV7527X 38 DBF/DBT SP 61 CH-257-1C 64 CP703 37 CV75X 38 DBF/DBT WT 61 CH-27 65 CP705 37 CV75Xi 38 DBF/DBT-1000BS 61 CH-27 65 CP707 37 CV75YX 38 DBF/DBT-100BS 61 CH-27 65 CP802 37 CV9012X 38 DBF/DBT-200BS 61 CH-27 65 CP803 37 CV9022Xi 38 DBF/DBT-300BS 61 CH-27 65 CP805 37 CV9027X 38 DBF/DBT-400BS 61 CH-2720-3C 64 CP807 37 CV90X 38 DBF/DBT-500BS 61 CH-2724-3C 64 CS 55 CV90Xi 38 DBF/DBT-600BS 61 CH-2748-3C 64 CS 12 60 CV90YX 38 DBF/DBT-700BS 61 CH-2757-3C 64 CS 6 60 CVB42X 38 DBF/DBT-800BS 61 CH-4 65 CSB 55 CVB60X 38 DBF/DBT-900BS 61 CH-4 65 CSW 55 CVB84X 38 DBF-10/DBT-10 61 CH-4 65 CTBDB 55 CVCBX 38 DBF-2/DBT-2 61 CH-420-1C 64 CTBDB-TP 55 CVSP 38 DBF-3/DBT-3 61 CH-424-1C 64 CTBDW 55 D1600 22 DBF-4/DBT-4 61 CH-427-1C 64 CTBSB 55 D1602 22 DBF-5/DBT-5 61 CH-448-1C 64 CTBSB-TP 55 D1603 22 DBF-6/DBT-6 61 CH-457-1C 64 CTBSW 55 D1610 22 DBF-7/DBT-7 61 CH-46C 71 CV10012X 38 D1612 22 DBF-8/DBT-8 61 CH-57C 71 CV10022Xi 38 D1613 22 DBF-9/DBT-9 61 CH-6 65 CV10027X 38 D2022H10BA 83 DBTS ECL 62 CH-6 65 CV100X 38 D2022H10BB 83 DBTS ECR 62 CH-6 65 CV100Xi 38 D2025H10DA 83 DBTS IC 62 Product Index Listing Model Page DBTS IECL 62 E2903-024HAW DBTS MF 62 E2903-024S DBTS OC 62 E2903-024SW DBTS SP 62 E2905-028C DBTS WT 62 DBTS-10 DBTS-1000BS Model Page Model Page 52 E3313T2RP 53 E3313T2RPW 44 E4810RPW 48 44 E4810TRPW 48 53 E3313T2SRP 54 E3313T2SRPW 45 E4815RPW 48 45 E4815TRPW E2905-028HAW 52 48 E3313TRP 44 E4875RPW 48 62 E2905-028S 62 E2905-028SW 53 E3313TRPW 44 E4875TRPW 48 53 E3313TSRP 45 E8801050 30 45 DBTS-100BS 62 E2906-036C 54 E3313TSRPW E8802075 30 DBTS-2 62 E2906-036HAW 52 E3321TD-RP 40 E8803100 30 DBTS-200BS 62 E2906-036S 53 E3322TD-RP 40 E8804125 30 DBTS-3 62 E2906-036SW 53 E3323TD-RP 40 E8805150 30 DBTS-300BS 62 E2907-040C 54 E3383D-RP 34 E8806200 30 52 E3703-024 50 EPETD8D 6 DBTS-4 62 E2907-040HAW DBTS-400BS 62 E2907-040S 53 E3703-024B 50 EPETD8D 9 DBTS-5 62 E2907-040SW 53 E3705-028 50 EPETD8D 83 DBTS-500BS 62 E2910-048C 54 E3705-028B 50 EPETD8S 6 DBTS-6 62 E2910-048HAW 52 E3706-036 50 EPETD8S 9 DBTS-600BS 62 E2910-048S 53 E3706-036B 50 EPETD8S 83 DBTS-7 62 E2910-048SW 53 E3707-040 50 EPETP8D 6 DBTS-700BS 62 E2912-060C 54 E3707-040B 50 EPETP8D 9 DBTS-8 62 E2912-060HAW 52 E3710-048 50 EPETP8D 83 DBTS-800BS 62 E2912-060S 53 E3710-048B 50 EPETP8S 6 DBTS-9 62 E2912-060SW 53 E3712-060 50 EPETP8S 9 DBTS-900BS 62 E2915-072C 54 E3712-060B 50 EPETP8S 83 DC-33 25 E2915-072HAW 52 E3715-072 50 ET5D4S 83 DC-46 25 E2915-072S 53 E3715-072B 50 ET5DS 83 DC-66 25 E2915-072SW 53 E3904-28 49 ET5DTS 83 DC-79 25 E3035DWBW 34 E3904-28C 49 ET5DWS 83 DCS1003 13 E3038DWBW 34 E3906-36 49 ET5MS 83 DCS1003/5100 17 E3055T2DWB 39 E3906-36C 49 ET5S4S 83 DCS202/5100 17 E3055TDWB 39 E3910-48 49 ET5SRS 83 DCS303 13 E3058T2DWB 39 E3910-48C 49 ET5SS 83 DCS403 13 E3058TDWB 39 E3912-60 49 ET5STS 83 DCS403/5100 17 E3210RPW 46 E3912-60C 49 ET5SWS 83 DCS603/5100 17 E3210TRPW 46 E3915-72 49 ETD5MS 83 DCS803 13 E3215RPW 46 E3915-72C 49 ETD5SS 83 DC-SK-1 64 E3215TRPW 46 E4310RP 47 ETD5STS 83 DC-SK-1 76 E3275RPW 46 E4310RPW 47 F1F2605CA1 21 DCS-MT303 23 E3275TRPW 46 E4310TRP 47 F1F2607CA1 21 DR115 55 E3312RP 44 E4310TRPW 47 F1F2610CA1 21 DR115B 55 E3312RPW 44 E4315RP 47 F1F5103N 16 DR115W 55 E3312T2RP 44 E4315RPW 47 F1F5103N 17 DS 55 E3312T2RPW 44 E4315TRP 47 F1F5105N 16 DS5105 15 E3312T2SRP 45 E4315TRPW 47 F1F5105N 17 DS51100 18 E3312T2SRPW 45 E4375RP 47 F1FUH03003 13 DS5120 15 E3312TRP 44 E4375RPW 47 F1FUH05003 13 DS5150 15 E3312TRPW 44 E4375TRP 47 F1FUH07CA1 13 DS5175 18 E3312TSRP 45 E4375TRPW 47 F1FUH10CA1 13 DSB 55 E3312TSRPW 45 E4410TRP 40 F1FUH12C03 13 DSW 55 E3313RP 44 E4415TRP 40 F1FUH15CO3 13 E2903-024C 54 E3313RPW 44 E4475TRP 40 F1FUH20CA1 13 5 INDEX Page Model Product Index Listing Page Model Page Model Page Model Page F1FUH25CA1 13 F2FUH05C03 13 F3725-120B 50 F3FUH30CA1 13 F1G7203 93 F2FUH10C03 13 F3904-28 49 F3G7203 93 F1G7205 93 F30522T2DWB 39 F3904-28C 49 F3G7205 93 F1G7305 95 F30522TDWB 39 F3906-36 49 F3G7305 95 F2903-024C 54 F3052T2DWB 39 F3906-36C 49 F4320RP 47 F2903-024HAW 52 F3052TDWB 39 F3910-48 49 F4320RPW 47 F2903-024S 53 F3220RPW 46 F3910-48C 49 F4320T2RP 47 F2903-024SW 53 F3220T2RPW 46 F3912-60 49 F4320T2RPW 47 Model INDEX 6 F2905-028C 54 F3316RP 44 F3912-60C 49 F4320TRP 47 F2905-028HAW 52 F3316RPW 44 F3915-72 49 F4320TRPW 47 F2905-028S 53 F3316T2RP 44 F3915-72C 49 F4420T2RP 40 F2905-028SW 53 F3316T2RPW 44 F3920-96 49 F4420TRP 40 F2906-036C 54 F3316T2SRP 45 F3920-96C 49 F4820RPW 48 F2906-036HAW 52 F3316T2SRPW 45 F3E7210 93 F4820T2RPW 48 F2906-036S 53 F3316TRP 44 F3E7210-2 93 F4820TRPW 48 F2906-036SW 53 F3316TRPW 44 F3E7215 93 F8801050 30 F2907-040C 54 F3316TSRP 45 F3E7215-2 93 F8802075 30 F2907-040HAW 52 F3316TSRPW 45 F3E7220-2 93 F8803100 30 F2907-040S 53 F3317RP 44 F3E7223-2 93 F8804125 30 F2907-040SW 53 F3317RPW 44 F3E7310 95 F8805150 30 F2910-048C 54 F3317T2RP 44 F3E7310-2 95 F8806200 30 F2910-048HAW 52 F3317T2RPW 44 F3E7312 95 FAM33 25 F2910-048S 53 F3317T2SRP 45 F3E7312-2 95 FAM46 25 F2910-048SW 53 F3317T2SRPW 45 F3E7315 95 FAM66 25 F2912-060C 54 F3317TRP 44 F3E7315-2 95 FAM79 25 F2912-060HAW 52 F3317TRPW 44 F3F2605CA1 21 FEC-30-120 74 F2912-060S 53 F3317TSRP 45 F3F2607CA1 21 FEC-30-240 74 F2912-060SW 53 F3317TSRPW 45 F3F2610CA1 21 FEC-60-120 74 F2915-072C 54 F3326TD-RP 40 F3F2615CA1 21 FEC-60-240 74 F2915-072HAW 52 F3327TD-RP 40 F3F2625CA1 21 FEP-0812-1RA 8 F2915-072S 53 F3386D-RP 34 F3F2630CA1 21 FEP-0820-1RA 8 F2915-072SW 53 F3387D-RP 34 F3F2640CA1 21 FEP-0820-3RA 9 F2917-084C 54 F3703-024 50 F3F2650CA1 21 FEP-0824-1RA 8 F2917-084S 53 F3703-024B 50 F3F5115CA1L 16 FEP-0824-3RA 9 F2917-084SW 53 F3705-028 50 F3F5115CA1L 17 FEP-0827-1RA 8 F2920-096C 54 F3705-028B 50 F3F5125CA1L 16 FEP-0848-1RA 8 F2920-096HAW 52 F3706-036 50 F3F5125CA1L 17 FEP-0848-3RA 9 F2920-096S 53 F3706-036B 50 F3F5130CA1L 16 FEP-1612-1RA 8 F2920-096SW 53 F3707-040 50 F3F5130CA1L 17 FEP-1620-1RA 8 F2925-120C 54 F3707-040B 50 F3F5140CA1L 16 FEP-1620-3RA 9 F2925-120HAW 52 F3710-048 50 F3F5140CA1L 17 FEP-1624-1RA 8 F2925-120S 53 F3710-048B 50 F3F5150CA1L 16 FEP-1624-3RA 9 F2925-120SW 53 F3712-060 50 F3F5150CA1L 17 FEP-1627-1RA 8 F2F5103N 16 F3712-060B 50 F3F5160CA1 19 FEP-1648-1RA 8 F2F5103N 17 F3715-072 50 F3F5170CA1 19 FEP-1648-3RA 9 F2F5105N 16 F3715-072B 50 F3FUH03C03 13 FEP-1657-1RA 8 F2F5105N 17 F3717-084 50 F3FUH07C03 13 FEP-1712-1RA 8 F2F5107CA1L 16 F3717-084B 50 F3FUH12C03 13 FEP-1720-1RA 8 F2F5107CA1L 17 F3720-096 50 F3FUH15C03 13 FEP-1720-3RA 9 F2F5110CA1L 16 F3720-096B 50 F3FUH20CA1 13 FEP-1724-1RA 8 F2F5110CA1L 17 F3725-120 50 F3FUH25CA1 13 FEP-1724-3RA 9 Product Index Listing Page Model Page Model Page Model Page FEP-1727-1RA 8 FES-4548-3 78 FS5101 19 G2907-048HAW 52 FEP-1748-1RA 8 FES-4560-3 78 FS5101 19 G2907-048S 53 FEP-1748-3RA 9 FFH-512A 72 FS5101 19 G2907-048SW 53 FEP-1812-1RA 8 FFH-912B 72 FS5101 19 G2909-060C 54 FEP-1820-1RA 8 FH15 81 FS5101 19 G2909-060HAW 52 FEP-1820-3RA 9 FH1T 81 FS5101 19 G2909-060S 53 FEP-1824-1RA 8 FHK-1 77 FS5102 17 G2909-060SW 53 FEP-1824-3RA 9 FHK-1324-3A 76 FS5102 19 G2910-048C 54 FEP-1827-1RA 8 FHK-1348-3A 76 FS5102 19 G2910-048HAW 52 FEP-1848-1RA 8 FHK-212-1CA 76 FS5102 19 G2910-048S 53 FEP-1848-3RA 9 FHK-224-1A 76 FS5102 19 G2910-048SW 53 FEP-3420-1RA 8 FHK-248-1A 76 FS5102 19 G2911-072C 54 G2911-072HAW 52 FHK-424-1A 76 FSW5111 17 8 FHK-448-1A 76 FSW5112 17 G2911-072S 53 9 FHK-624-1CA 76 FSW5112 19 G2911-072SW 53 FEP-3427-1RA 8 FHK-624-3A 76 FSW5112 22 G2912-060C 54 FEP-3448-1RA 8 FHK-648-3A 76 G1G2605CA1 21 G2912-060HAW 52 FEP-3448-3RA 9 FPC2110 75 G1G2607CA1 21 G2912-060S 53 FEP-3457-1RA 8 FPC2120 75 G1G2610CA1 21 G2912-060SW 53 FEP-3620-1RA 8 FPC2140 75 G1G5103N 16 G2913-084C 54 FEP-3620-3RA 9 FPC2160 75 G1G5103N 17 G2913-084S 53 FEP-3624-1RA 8 FPC2210 75 G1G5105N 16 G2913-084SW 53 FEP-3624-3RA 9 FPC2220 75 G1G5105N 17 G2915-072C 54 FEP-3627-1RA 8 FPC2240 75 G1G5107CA1L 16 G2915-072HAW 52 FEP-3648-1RA 8 FPC2260 75 G1G5107CA1L 17 G2915-072S 53 G2915-072SW 53 FEP-3420-3RA 9 FEP-3424-1RA FEP-3424-3RA FEP-3648-3RA 9 FPC4110 75 G1G5110CA1N 16 FEP-3657-1RA 8 FPC4120 75 G1G5110CA1N 17 G2915-096C 54 FEP-3820-1RA 8 FPC4140 75 G1G7203 93 G2915-096HAW 52 FEP-3820-3RA 9 FPC4160 75 G1G7205 93 G2915-096S 53 FEP-3824-1RA 8 FPC4210 75 G1G7305 95 G2915-096SW 53 FEP-3824-3RA 9 FPC4220 75 G1GUH03003 13 G2917-084C 54 FEP-38271-RA 8 FPC4240 75 G1GUH05003 13 G2917-084S 53 FEP-3848-1RA 8 FPC4260 75 G1GUH07CA1 13 G2917-084SW 53 FEP3848-3RA 9 FPC7110 75 G1GUH10CA1 13 G2918-120C 54 FEP-7620-1RA 8 FPC7120 75 G2903-024C 54 G2918-120HAW 52 FEP-7620-3RA 9 FPC7140 75 G2903-024HAW 52 G2918-120S 53 FEP-7624-1RA 8 FPC7160 75 G2903-024S 53 G2918-120SW 53 FEP-7624-3RA 9 FPC7210 75 G2903-024SW 53 G2920-096C 54 G2920-096HAW 52 FEP-7627-1RA 8 FPC7220 75 G2905-028C 54 FEP-7648-1RA 8 FPC7240 75 G2905-028HAW 52 G2920-096S 53 FEP-7648-3RA 9 FPC7260 75 G2905-028S 53 G2920-096SW 53 FEP-7657-1RA 8 FPC8110 75 G2905-028SW 53 G2925-120C 54 FES-0924-1C 78 FPC8120 75 G2906-036C 54 G2925-120HAW 52 FES-1024-1CA 78 FPC8140 75 G2906-036HAW 52 G2925-120S 53 FES-1520-3A 78 FPC8160 75 G2906-036S 53 G2925-120SW 53 FES-1524-1A 78 FPC8210 75 G2906-036SW 53 G3032DWBW 34 FES-1524-3E 78 FPC8220 75 G2907-040C 54 G3052T2DWB 39 FES-1548-3E 78 FPC8240 75 G2907-040HAW 52 G3052TDWB 39 FES-1560-3A 78 FPC8260 75 G2907-040S 53 G3314RP 44 FES-3048-3A 78 FS5101 17 G2907-040SW 53 G3314RPW 44 FES-3060-3A 78 FS5101 19 G2907-048C 54 G3314T2RP 44 7 INDEX Model Product Index Listing Page Model Page Model Page Model Page G3314T2RPW 44 G3715-072 50 H2903-024S 53 H2925-120CI 54 Model INDEX 8 G3314TRP 44 G3715-072B 50 H2903-024SW 53 H2925-120HAW 52 G3314TRPW 44 G3715-096 50 H2903-24AWi 52 H2925-120S 53 G3315RP 44 H2905-028C 54 H2925-120SW 53 G3315RPW G3315T2RP G3715-096B 50 44 G3717-084 50 H2905-028CI 54 H2HUH05C03 13 44 G3717-084B 50 H2905-028HAW 52 H2HUH07C03 13 34 G3315T2RPW 44 G3718-120 50 H2905-028S 53 H3032DWBW G3718-120B 50 H2905-028SW 53 H30522T2DWB 39 52 H30522TDWB 39 G3315TRP 44 G3315TRPW 44 G3720-096 50 H2905-28AWi G3316RP 44 G3720-096B 50 H2906-036C 54 H3052T2DWB 39 G3316RPW 44 G3725-120 50 H2906-036C 54 H3052TDWB 39 H2906-036HAW 52 H3275RPW 46 G3316T2RP 44 G3316T2RPW G3316TRP G3316TRPW G3317RP G3725-120B 50 44 G3904-28 49 H2906-036S 53 H3275T2RPW 46 44 G3904-28C 49 H2906-036SW 53 H3317RP 44 44 G3906-36 49 H2906-36AWi 52 H3317RPW 44 44 G3906-36C 49 H2907-040C 54 H3317T2RP 44 H3317T2RPW 44 G3317RPW 44 G3910-48 49 H2907-040C 54 G3317T2RP 44 G3910-48C 49 H2907-040HAW 52 H3317T2SRP 45 G3317T2RPW 44 G3912-60 49 H2907-040S 53 H3317T2SRPW 45 44 G3317TRP 44 G3912-60C 49 H2907-040SW 53 H3317TRP G3915-72 49 H2907-40AWi 52 H3317TRPW 44 G3915-72C 49 H2910-048C 54 H3317TSRP 45 G3317TRPW 44 G3323TD-RP 40 G3324TD-RP 40 G3920-96 49 H2910-048CI 54 H3317TSRPW 45 G3325TD-RP 40 G3920-96C 49 H2910-048HAW 52 H3327TD-RP 40 H3387D-RP 34 G3326TD-RP 40 G8801050 30 H2910-048S 53 G3327TD-RP 40 G8802075 30 H2910-048SW 53 H3703-024 50 G3383D-RP 34 G8803100 30 H2910-48AWi 52 H3703-024B 50 G3384D-RP 34 G8804125 30 H2912-060C 54 H3705-028 50 G3385D-RP 34 G8805150 30 H2912-060C 54 H3705-028B 50 H2912-060HAW 52 H3706-036 50 G3386D-RP 34 G8806200 30 G3387D-RP 34 GCH-4000 80 H2912-060S 53 H3706-036B 50 G3703-024 50 GF-SK-1 64 H2912-060SW 53 H3707-040 50 H3707-040B 50 G3703-024B 50 GF-SK-1 76 H2912-60AWi 52 H1D1AA 85 H2915-072C 54 H3710-048 50 H3710-048B 50 G3705-028 50 G3705-028B 50 H1G7203 93 H2915-072CI 54 G3706-036 50 H1G7205 93 H2915-072HAW 52 H3712-060 50 G3706-036B 50 H1G7305 95 H2915-072S 53 H3712-060B 50 50 G3707-040 50 H1H2605CA1 21 H2915-072SW 53 H3715-072 G3707-040B 50 H1H2607CA1 21 H2915-72AWi 52 H3715-072B 50 G3707-048 50 H1H2610CA1 21 H2917-084C 54 H3717-084 50 G3707-048B 50 H1HUH03003 13 H2917-084CI 54 H3717-084B 50 G3709-060 50 H1HUH05003 13 H2917-084S 53 H3720-096 50 H3720-096B 50 G3709-060B 50 H1HUH07CA1 13 H2917-084SW 53 G3710-048 50 H1HUH12C03 13 H2917-84AWi 52 H3725-120 50 G3710-048B 50 H1HUH15C03 13 H2920-096C 54 H3725-120B 50 G3711-072 50 H1HUH20CA1 13 H2920-096CI 54 H3904-28 49 G3711-072B 50 H1HUH25CA1 13 H2920-096HAW 52 H3904-28C 49 G3712-060 50 H2920-096S 53 H3906-36 49 G3712-060B G3713-084 G3713-084B H1HUH30CA1 13 50 H2903-024C 54 H2920-096SW 53 H3906-36C 49 50 H2903-024CI 54 H2920-120AWi 52 H3910-48 49 54 H3910-48C 49 50 H2903-024HAW 52 H2925-120C Product Index Listing Page Model Page Model Page Model Page H3912-60 49 H8805150i 30 HF3325TD-RP 40 HF4810T2RPW 48 H3912-60C 49 H8806200 30 HF3326TD-RP 40 HF4815RPW 48 H3915-72 49 H8806200i 30 HF3384D-RP 34 HF4815T2RPW 48 H3915-72C 49 HDWG-13 64 HF3385D-RP 34 HF4820RPW 48 H3920-96 49 HDWG-2 64 HF3386D-RP 34 HF4820T2RPW 48 H3920-96C 49 HDWG-27 64 HF3B51100CA1 19 HF4875RPW 48 H3G7203 93 HDWG-4 64 HF3B5115CA1L 16 HF4875T2RPW 48 H3G7205 93 HDWG-6 64 HF3B5115CA1L 17 HF5605T 23 H3G7210 93 HF1B5103N 16 HF3B5120CA1L 16 HF684TC 80 H3G7210-2 93 HF1B5103N 17 HF3B5120CA1L 17 HF685TC 80 H3G7215 93 HF1B5105N 16 HF3B5125CA1L 16 HF686TC 80 H3G7215-2 93 HF1B5105N 17 HF3B5125CA1L 17 HIHUH10CA1 13 H3G7220-2 93 HF2B5103N 16 HF3B5130CA1L 16 HLA 12-208160-3.0-24 5 H3G7223-2 93 HF2B5103N 17 HF3B5130CA1L 17 HLA 12-208160-5.0-24 5 H3G7230-2 93 HF2B5105N 16 HF3B5140CA1L 16 HLA 12-208160-7.5-24 5 H3G7305 95 HF2B5105N 17 HF3B5140CA1L 17 HLA 12-208360-3.0-24 5 H3G7310 95 HF2B5107CA1L 16 HF3B5150CA1L 16 HLA 12-208360-5.0-24 5 H3G7310-2 95 HF2B5107CA1L 17 HF3B5150CA1L 17 HLA 12-208360-7.5-24 5 H3G7312 95 HF2B5110CA1L 16 HF3B5160CA1 19 HLA 12-240160-3.0-24 5 H3G7312-2 95 HF2B5110CA1L 17 HF3B5170CA1 19 HLA 12-240160-5.0-24 5 H3G7315 95 HF2HUH10C03 13 HF3B5180CA1 19 HLA 12-240160-7.5-24 5 H3G7315-2 95 HF3210RPW 46 HF3B5190CA1 19 HLA 12-240360-3.0-24 5 H3H2605CA1 21 HF3210T2RPW 46 HF4310RP 47 HLA 12-240360-5.0-24 5 H3H2607CA1 21 HF3215RPW 46 HF4310RPW 47 HLA 12-240360-7.5-24 5 H3H2610CA1 21 HF3215T2RPW 46 HF4310T2RP 47 HLA 12-480360-3.0-24 5 H3H2615CA1 21 HF3220RPW 46 HF4310T2RPW 47 HLA 12-480360-5.0-24 5 H3H2620CA1 21 HF3220T2RPW 46 HF4310TRP 47 HLA 12-480360-7.5-24 5 H3H2625CA1 21 HF3222RPW 46 HF4310TRPW 47 HLA 16-208360-10.0-24 5 H3H2630CA1 21 HF3222T2RPW 46 HF4315RP 47 HLA 16-240160-10.0-24 5 H3H2640CA1 21 HF3315RP 44 HF4315RPW 47 HLA 16-240360-10.0-24 5 H3H2650CA1 21 HF3315RPW 44 HF4315T2RP 47 HLA 16-480360-10.0-24 5 H3H5605T 23 HF3315T2RP 44 HF4315T2RPW 47 HLA 20-208360-15.0-24 5 H3HUH03C03 13 HF3315T2RPW 44 HF4315TRP 47 HLA 20-240360-15.0-24 5 H3HUH12C03 13 HF3315T2SRP 45 HF4315TRPW 47 HLA 20-480360-15.0-24 5 H3HUH15C03 13 HF3315T2SRPW 45 HF4320RP 47 HLA 20-480360-20.0-24 5 H3HUH20CA1 13 HF3315TRP 44 HF4320RPW 47 HLA 20-480360-25.0-24 5 H3HUH25CA1 13 HF3315TRPW 44 HF4320T2RP 47 HLA 20-600360-15.0-24 5 H3HUH30CA1 13 HF3315TSRP 45 HF4320T2RPW 47 HLA 20-600360-20.0-24 5 H46D1214 85 HF3315TSRPW 45 HF4320TRP 47 HLA 20-600360-25.0-24 5 H474 TMC 80 HF3316RP 44 HF4320TRPW 47 HLHM 6 H5520/HMK 10 HF3316RPW 44 HF4375RP 47 HLPM1015 6 H5550/HMK 10 HF3316T2RP 44 HF4375RPW 47 HLPM1525 6 H8801050 30 HF3316T2RPW 44 HF4375T2RP 47 HLPM37 6 H8801050i 30 HF3316T2SRP 45 HF4375T2RPW 47 HLT-1 6 H8802075 30 HF3316T2SRPW 45 HF4375TRP 47 HLT-1 9 H8802075i 30 HF3316TRP 44 HF4375TRPW 47 HLT-1 83 6 H8803100 30 HF3316TRPW 44 HF4410T2RP 40 HLT-2 H8803100i 30 HF3316TSRP 45 HF4415T2RP 40 HLT-2 9 H8804125 30 HF3316TSRPW 45 HF4420T2RP 40 HLT-2 83 H8804125i 30 HF3323TD-RP 40 HF4475T2RP 40 HLWM10 6 H8805150 30 HF3324TD-RP 40 HF4810RPW 48 HLWM1525 6 9 INDEX Model Product Index Listing Page Model Page Model Page Model Page HLWM37 6 LVRSB 55 MFHE-0300-6-EAACRP 92 OCHWG-57 70 HP-11-QT 77 LVRSW 55 MFHE-0300-6-EAARP 92 OCHWG-57 71 HP-5-QT 77 LVTR 60 MFHE-0300-6-FAAF2D 92 OFG 51100 18 HP6-1000120-2CT 91 M2903-024CI 54 MFHE-0300-6-HAA 92 OFG 5175 18 Model INDEX 10 HP6-1000120-2CT 91 M2903-24AWi 52 MFHE-0300-6-HAAF2D 92 OFG5101 15 HP6-1000120-2CTRP 92 M2905-028CI 54 MFHE-0300-6-HAARP 92 OFG5102 15 HP6-1000120-2T 91 M2905-28AWi 52 MFHE-0300-8-EAA 92 OFG5103 15 HP6-1000120-2T 91 M2906-036CI 54 MFHE-0300-8-EAAC 92 P3G7203 93 HP6-1000120-2TRP 92 M2906-36AWi 52 MFHE-0300-8-EAACRP 92 P3G7205 93 HP6C-12PK 91 M2907-040CI 54 MFHE-0300-8-EAARP 92 P3G7210 93 HP6H-12PK 91 M2907-40AWi 52 MFHE-0300-8-HAA 92 P3G7210-2 93 HP-6-QT 77 M2910-048CI 54 MFHE-0300-8-HAARP 92 P3G7215 93 HP8-1440120-2CT 91 M2910-48AWi 52 MM-13A 72 P3G7215-2 93 HP8-1440120-2CT 91 M2912-060CI 54 MM-18A 72 P3G7220-2 93 HP8-1440120-2CTRP 92 M2912-60AWi 52 MM-24A 72 P3G7225-2 93 HP8-1440120-2T 91 M2915-072CI 54 MM-33A 72 P3G7230-2 93 93 M2915-72AWi 52 MM-46A 72 P3G7235-2 92 M2917-084CI 54 MS4122 33 P3G7240-2 93 91 M2917-84AWi 52 MS4123 33 P3G7245-2 93 91 M2920-096CI 54 MS4124 33 P3G7250-2 93 80 M2925-120AWi 52 MS4125 33 P3G7305 95 IDS 60 M2925-120CI 54 MS4126 33 P3G7310 95 IDS 30 60 M3210T2RPWi 46 MSE4120-12 33 P3G7310-2 95 IDS 40 60 M3215T2RPWi 46 N3472T2i 36 P3G7312 95 ITD 60 M3220T2RPWi 46 N3473T2i 36 P3G7312-2 95 ITS 60 M3222T2RPWi 46 N3474T2i 36 P3G7315 95 J3326TD-RP 40 M3315T2SRPWi 45 N3482T2i 35 P3G7315-2 95 J3327TD-RP 40 M3316T2SRPWi 45 N3483T2i 35 P3G7318 95 JK 55 M3324TD-RPi 40 N3484T2i 35 P3G7318-2 95 21 HP8-1440120-2T 91 HP8-1440120-2TRP HP8C-12PK HP8H-12PK ICH-240C JKB 55 M3325TD-RPi 40 OCH-46-120V 70 P3P2605CA1 JKW 55 M3384D-RPi 34 OCH-46-120V-SS 70 P3P2607CA1 21 K3326TD-RP 40 M3385D-RPi 34 OCH-46-208V 70 P3P2610CA1 21 K3327TD-RP 40 M3386D-RPi 34 OCH-46-208V-SS 70 P3P2615CA1 21 KB33 25 M3472T2i 36 OCH-46-240V 70 P3P2620CA1 21 KB46 25 M3473T2i 36 OCH-46-240V-SS 70 P3P2625CA1 21 KB66 25 M3474T2i 36 OCH-46-277V 70 P3P2630CA1 21 KB79 25 M3482T2i 35 OCH-46-277V-SS 70 P3P2640CA1 21 KT110 84 M3483T2i 35 OCH-57-208V 70 P3P2650CA1 21 KT121 84 M3484T2i 35 OCH-57-208V-SS 70 P3P5103CA1N 16 KTD110 84 M4310T2RPi 47 OCH-57-240V 70 P3P5103CA1N 17 KTO110 84 M4315T2RPi 47 OCH-57-240V-SS 70 P3P5105CA1N 16 KTO121 84 M4320T2RPi 47 OCH-57-277V 70 P3P5105CA1N 17 OCH-57-277V-SS 70 P3P5107CA1L 17 L06Y-01 84 M4375T2RPi 47 L08Y-01 84 M8801050i 30 OCH-57-480V 70 P3P5107CA1N 16 L8801050 30 M8802075i 30 OCH-57-480V-SS 70 P3P51100CA1 19 L8802075 30 M8803100i 30 OCH-EBK-120 70 P3P5110CA1N 16 L8803100 30 M8804125i 30 OCH-EBK-208 70 P3P5110CA1N 17 L8804125 30 P3P5115CA1L 17 L8805150 L8806200 LVRS M8805150i 30 OCH-EBK-240 70 30 M8806200i 30 OCH-EBK-480 70 P3P5115CA1N 16 30 MFHE-0300-6-EAA 92 OCHWG-46 70 P3P5120CA1N 16 55 MFHE-0300-6-EAAC 92 OCHWG-46 71 P3P5120CA1N 17 Product Index Listing Model Page Model Page Model Page 16 PHLA12-208160-5.0-24-TDP 7 R3H5140CA1 16 RFR-5 85 P3P5125CA1N 17 PHLA12-208160-7.5-24-TDP 7 RCP122 37 RFT-1 85 P3P5130CA1N 16 PHLA12-208360-3.0-24-TDP 7 RCP122i 37 RHG-1012A 77 P3P5130CA1N 17 PHLA12-208360-5.0-24-TDP 7 RCP123 37 RHG-1012B 77 P3P5140CA1N 16 PHLA12-208360-7.5-24-TDP 7 RCP123i 37 RK120EAA 87 P3P5140CA1N 17 PHLA12-240160-3.0-24-TDP 7 RCP125 37 RK124EAA 87 P3P5150CA1N 16 PHLA12-240160-5.0-24-TDP 7 RCP125i 37 RK130EAA 87 P3P5150CA1N 17 PHLA12-240160-7.5-24-TDP 7 RCP127 37 RK134EAA 87 P3P5160CA1 19 PHLA12-240360-3.0-24-TDP 7 RCP127i 37 RKWP1AA 87 P3P5170CA1 19 PHLA12-240360-5.0-24-TDP 7 RCP2202i 37 RMF-222-A 69 P3P5180CA1 19 PHLA12-240360-7.5-24-TDP 7 RCP2203i 37 RMF-222-SS-A 69 P3P5190CA1 19 PHLA12-480360-3.0-24-TDP 7 RCP2205i 37 RMF-223-SS 69 P3P5605T 23 PHLA12-480360-5.0-24-TDP 7 RCP2207i 37 RMF-342-A 69 P3PUH03CA1 13 PHLA12-480360-7.5-24-TDP 7 RCP702 37 RMF-342-SS-A 69 P3PUH05CA1 13 PHLA12-600360-3.0-24-TDP 7 RCP703 37 RMF-343-SS 69 P3PUH07CA1 13 PHLA12-600360-5.0-24-TDP 7 RCP705 37 RMF-462-A 69 P3PUH10CA1 13 PHLA12-600360-7.5-24-TDP 7 RCP707 37 RMF-462-SS-A 69 P3PUH12CA1 13 PHLA16-208360-10.0-24-TDP 7 RCP802 37 RMF-463-SS 69 P3PUH15CA1 13 PHLA16-240160-10.0-24-TDP 7 RCP803 37 RPH1-5A 81 P3PUH20CA1 13 PHLA16-240360-10.0-24-TDP 7 RCP805 37 RPH-208-A 72 P3PUH25CA1 13 PHLA16-480360-10.0-24-TDP 7 RCP807 37 RPH22-5Ai 81 P3PUH30CA1 13 PHLA16-600360-10.0-24-TDP 7 RD5120 15 RPH22-5ASi 81 P3PUH40CA1 13 PHLA20-208360-15.0-24-TDP 7 RD5120 15 RPH-240-A 72 P3PUH48CA1 13 PHLA20-240360-15.0-24-TDP 7 RD5150 15 RPH2-5A 81 P5520/PMK 10 PHLA20-480360-15.0-24-TDP 7 RD5150 15 RPH2-5Ai 81 P5550/PMK 10 PHLA20-480360-20.0-24-TDP 7 RD5175 15 RPH2-5ASi 81 P8801050 30 PHLA20-480360-25.0-24-TDP 7 RDBT-PD-10 63 S2022H10AA 83 P8802075 30 PHLA20-600360-15.0-24-TDP 7 RDBT-PD-1000BS 63 S2022H10AB 83 P8803100 30 PHLA20-600360-20.0-24-TDP 7 RDBT-PD-100BS 63 S2025H10AA 83 P8804125 30 PHLA20-600360-25.0-24-TDP 7 RDBT-PD-2 63 SB-6* 92 P8805150 30 PR 120-277/120 60 RDBT-PD-200BS 63 SB6-120-CT 91 P8806200 30 PR 120-277/24 60 RDBT-PD-3 63 SB6-120-T 91 PCH-48C 77 PR 120-277/240 60 RDBT-PD-300BS 63 SB-8* 92 PD10-1018-1 97 PT3480 35 RDBT-PD-4 63 SB8-120-CT 91 PD10-1018-3 97 Q3H5103CA1 16 RDBT-PD-400BS 63 16 RDBT-PD-5 63 91 19 37 37 78 78 P3P5125CA1N PD15-1218-1 97 Q3H5105CA1 PD15-1218-1-3 97 Q3H5107CA1 16 RDBT-PD-500BS 63 PD15-1218-2-3 97 Q3H5110CA1 16 RDBT-PD-6 63 PD20-1220-1 97 Q3H5115CA1 16 RDBT-PD-600BS 63 SB8-120-T SC5100 SF200 SF400 SO 12/4 SO 4/3 PD20-1220-3 97 Q3H5120CA1 16 RDBT-PD-7 63 SO 4/4 78 PD25-1620-1 97 Q3H5125CA1 16 RDBT-PD-700BS 63 SO 6/4 78 PD25-1620-3 97 Q3H5130CA1 16 RDBT-PD-8 63 SR120 55 PD30-1624-2-3 97 Q3H5140CA1 16 RDBT-PD-800BS 63 SR120B 55 PD30-1624-3-3 97 R3H5103CA1 16 RDBT-PD-9 63 SR120W 55 PD35-1624-3 97 R3H5105CA1 16 RDBT-PD-900BS 63 SR220 55 97 R3H5107CA1 16 RDBT-PDIC 63 SR220B 55 55 PD40-1624-3 R3H5110CA1 16 RDBT-PDIECL 63 SR220W 97 R3H5115CA1 16 RDBT-PDIECR 63 T1 8 PD5-812-1 97 R3H5120CA1 16 RDBT-PDOC 63 T2 8 PD-812-3 97 R3H5125CA1 16 RFKit-5 85 T33D052033B30D0F 25 PHLA12-208160-3.0-24-TDP 7 R3H5130CA1 16 RFKIT-5 92 T33D052433B30D0F 25 PD45-1630-3 97 PD50-1630-3 11 INDEX Page Model Product Index Listing Page Model Page Model Page T33D054833B30D0F 25 TW123 / TH5220D 86 WWA06 55 Model INDEX 12 T4398A1021 85 TW145 84 WWA07 55 T46D102433B30D0F 25 TW146 84 WWA08 55 T46D104833B30D0F 25 TW1510 17 WWA09 55 T5100 17 TW1512 17 YES-1520-3A 78 T5100 17 TW155A 11 YES-1524-1A 78 T5102 17 TW155A 84 YES-1524-3E 78 T5122 17 TW255A 11 YES-1548-3E 78 TAT20-480-3/3BB/1T 89 TW255A 84 YES-3048-3A 78 TAT-24-FAN-120V-1 89 U3H2605CA4 21 TAT-30 89 U3H2607CA4 21 TAT-45 89 U3H2610CA4 21 TAT5-208-1/3BB/1T 89 U3H2615CA4 21 TAT5-240-1/3BB/1T 89 U3H2620CA4 21 TAT8-208-1/3BB/1T 89 U3U2625CA1 21 TAT8-240-1/3BB/1T 89 U3U2630CA1 21 TAT-ILC-25 89 U3U2640CA1 21 TB3000 34 U3U2650CA1 21 TB3380 34 U8801050 30 TBD 55 U8802075 30 TBD-TP 55 U8803100 30 TBS 55 U8804125 30 TBS-TP 55 U8805150 30 TC1602 17 U8806200 30 TC1602 22 UHB-1 13 TC5102 17 UHB-3 13 TC5102 19 UHB-4 13 TC5103 17 UT1001 87 TF-33 25 UT3001 87 TF-46 25 UT5001 87 TF-66 25 UT6001 87 TF-79 25 UT8001 87 TFS5101 17 UT9001 87 TFS5101 19 V5105 15 TFS5102 17 V51100 18 TG1 87 V5120 15 TG1B 87 V5150 15 TG2 87 VHC-15 70 TG2B 87 VHC-15 74 TG3 87 VHC-32 70 TG3B 87 VHC-32 74 TH115-A-024T 86 VMB-41-SS 69 TH148LE-P 86 VMB-41-SS 70 TL8230A1003 85 W5520/WMK 10 TO-SK-1 76 W5550/WMK 10 TSH1TX 81 WWA00 55 TSH20J 81 WWA01 55 TSH20JW 81 WWA02 55 TSH2TX 81 WWA03 55 TUH1 13 WWA04 55 17 WWA05 55 TW123 Model Page
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf Linearized : No Create Date : 2013:09:11 10:07:35 Modify Date : 2013:09:11 10:07:36 Author : Page Count : 121 XMP Toolkit : TallComponents PDFObjects 1.0 Producer : PDFKit.NET 4.0.24.0 Keywords : PDF Version : 1.4 Creator Tool : Metadata Date : 2013:09:11 10:07:36-04:00 Creator : Subject : Description : Title : Format : application/pdfEXIF Metadata provided by EXIF.tools