Product Detail Manual
2014-09-05
: Pdf 104333-Attachment 104333-Attachment 686334 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 121 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- Amperage Chart & Electric Heat Limited Warranty
- Electric Heat Comfort Zones
- Hazardous Location & Washdown
- Unit Heaters
- Convector Heaters
- Ceiling Heaters
- Wall Heaters
- Electric Baseboard Heaters
- Draft Barrier Heaters
- Electric Infrared Heaters
- MR Series Heavy Duty Metal Sheath
- TH & THSS Series Mul-T-Mount
- OCH Series Outdoor/Indoor Rated Quartz
- RPH | MM | FFH Series
- Electric Infrared Heating Elements
- Electric Infrared Heating Controls
- FHK Series Portable Metal Sheath
- CH Series Portable Quartz
- PCH Series Portable Quartz Spot Heater
- RHG Series Infrared Heat Gun
- HP Series Portable Heat Panel
- Portable Heaters
- Specialty Heaters & Air Curtains
- Thermostats & Controls
- Thermal Area Treatment Heaters
- Duct Heaters
- Product Index Listing
2
Amperage Chart & Electric Heat Products Limited Warranty
Products manufactured by TPI Corporation
are warranted to the original consumer
to be free from defects in material and
workmanship for twelve (12) months from
the original date of purchase. The TPI
warranty does not cover products modied
outside our factory, damage or failure caused
by acts of God, abuse, misuse, connected to or
placed on other than rated voltage, abnormal
usage, faulty installation, failure to follow
suggested maintenance procedures enclosed
with the product, improper maintenance or
any repairs other than those provided by an
authorized TPI Corporation service center.
There are no obligations or liabilities on the
part of the corporation for consequential
damages arising out of, or in connection
with, the use or performance of the product,
or other indirect damages with respect to loss
of property, revenues, or prot, or costs of
removal, installation or reinstallation.
All implied warranties with respect to TPI
products, including implied warranties for
merchantability and implied warranties for
tness, are limited in duration to twelve
(12) months from original date of purchase,
except those products or parts of products
which are warranted for longer periods. On
such products or parts of products all implied
warranties for merchantability and tness
are limited to the duration of the extended
warranty period thereon.
Some states do no allow the exclusion or
limitation of incidental or consequential
damages and some states do not allow
limitations on how long an implied warranty
lasts. The above exclusions or limitations
may not apply to you.
During the warranty period, TPI Corporation
will, at its sole option, repair or replace
any defective parts or products returned,
freight prepaid, to the TPI Corporation
factory or such other location as TPI
Corporation may designate. Returned
products must be packaged carefully and
TPI Corporation shall not be responsible for
damage in transit. When returning parts,
the owner must provide the model number
of the product and nature of difculty being
experienced. This warranty does not obligate
TPI Corporation to bear the cost of labor in
replacing any assembly, unit or component
part thereof, nor does the company assume
any liability for secondary charges, expenses
for installing or removal, freight or damages.
There will be charges rendered for product
repairs made after out warranty period has
expired. Proof of purchase, including date,
must accompany request for in-warranty
service. In any event, TPI Corporation’s
maximum liability shall not in any case
exceed the list price for the product claimed
to be defective. This warranty gives to you
specic legal rights and you may have other
rights, which may vary, from state to state.
For the name of you nearest authorized TPI
Corporation service center, please write to
TPI Corporation, P.O. Box 4973, Johnson
City, Tennessee, 37602.
In addition to the Limited Warranty stated
above covering general products, TPI
Corporation extends this warranty on
the following listed products, which are
warranted to the original consumer from the
original date of purchase for the total time
periods indicated herein to the left:
Heat Products
198 Series Elements 1 Year
Elements in Baseboard 10 Years
All Other Heating Products 1 Year
Thermostats & Controls 2 Years
K.W
Rating B.T.U.H.
208 Volt
AMP Rating
220 Volt
AMP Rating
230 Volt
AMP Rating
240 Volt
AMP Rating
277
Volt
AMP
Rating
440
Volt
AMP
Rating
480
Volt
AMP
Rating
550
Volt
AMP
Rating
1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 3 PH 3 PH
00.5 1,706 2.4 1.4 2.3 1.3 2.2 1.3 2.1 1.2 1.8 0.6 0.6 0.5
01.0 3,413 4.8 2.8 4.5 2.6 4.3 2.5 4.2 2.4 3.6 1.3 1.2 1.0
02.0 6,826 9.6 5.5 9.1 5.2 8.7 5.0 8.3 4.8 7.2 2.6 2.4 2.1
03.0 10,239 14.4 8.3 13.6 7.9 13.0 7.5 12.5 7.2 10.8 3.9 3.6 3.1
04.0 13,652 19.2 11.1 18.2 10.4 17.5 10.1 16.6 9.6 14.4 5.2 4.8 4.2
05.0 17,065 24.0 13.8 22.7 13.1 21.7 12.6 20.8 12.0 18.1 6.6 6.0 5.2
06.0 20,478 28.8 16.6 27.3 15.7 26.1 15.1 25.0 14.4 21.7 7.9 7.2 6.3
07.0 23,891 33.6 19.4 31.8 18.4 30.4 17.6 29.1 16.8 25.3 9.2 8.4 7.3
08.0 27,304 38.5 22.2 36.4 20.9 34.9 20.1 33.3 19.2 28.9 10.5 9.6 8.4
09.0 30,717 42.8 24.9 40.9 23.3 39.1 22.6 37.7 21.4 32.5 11.8 10.8 9.5
10.0 34,130 48.1 27.4 45.4 26.2 43.5 25.1 41.7 24.0 36.1 13.2 12.0 10.5
11.0 37,543 52.9 30.5 50.0 28.6 47.8 27.6 45.8 26.4 39.7 14.5 13.2 11.6
12.0 40,956 57.7 33.2 54.5 31.5 52.1 30.2 50.0 28.6 43.3 15.8 14.4 12.6
13.0 44,369 62.5 36.0 59.1 34.1 56.9 32.7 54.2 31.3 46.9 17.1 15.6 13.7
14.0 47,782 67.3 38.8 63.6 36.7 60.9 35.2 58.3 33.7 50.5 18.4 16.8 14.7
15.0 51,195 72.1 41.5 68.2 39.1 65.2 37.7 62.5 35.1 54.2 19.8 18.0 15.8
16.0 54,608 76.9 44.3 72.7 41.9 69.6 40.2 66.7 38.5 57.8 21.1 19.2 16.9
17.0 58,021 81.7 47.1 77.3 44.3 73.9 42.7 70.8 40.9 61.4 22.4 20.4 17.9
18.0 61,434 86.5 49.8 81.8 47.2 78.3 45.2 75.0 43.3 65.0 23.7 21.6 19.0
19.0 64,847 91.3 52.6 86.4 49.6 82.6 47.7 79.2 45.7 68.6 25.1 22.8 20.0
20.0 68,260 96.1 55.1 90.9 52.5 86.9 50.3 83.3 48.1 72.2 26.4 24.0 21.1
21.0 71,673 100.0 58.2 95.6 55.1 91.3 52.9 87.5 50.5 75.8 27.7 25.2 22.1
22.0 75,086 105.8 60.9 100.0 57.7 95.7 55.3 91.7 52.9 79.4 29.0 26.4 23.1
23.0 78,499 110.6 63.7 14.5 60.4 100.0 57.9 95.8 55.3 83.0 30.3 27.6 24.3
24.0 81,912 115.4 66.5 109.1 62.9 104.3 60.3 100.0 57.7 86.6 31.7 28.8 25.3
25.0 85,325 120.2 69.2 113.6 65.3 108.6 62.8 104.1 60.1 90.3 33.0 30.1 26.4
26.0 88,738 125.0 72.0 118.2 68.3 113.0 65.3 108.3 62.5 93.9 34.3 31.3 27.4
27.0 92,151 129.8 74.8 122.7 70.9 117.4 67.8 112.5 64.7 97.5 35.6 32.5 28.5
28.0 95,564 134.6 77.2 128.2 73.5 121.7 70.3 116.6 67.3 101.1 36.9 33.7 29.5
29.0 98,977 139.4 80.3 131.8 76.0 126.0 72.9 120.8 69.7 104.7 38.3 34.9 30.6
30.0 102,390 144.2 83.1 136.4 78.7 130.4 75.4 125.0 72.1 108.3 39.6 36.1 31.7
31.0 105,803 149.0 85.9 140.9 81.3 134.7 77.9 129.2 74.5 111.9 40.9 37.3 32.7
32.0 109,216 153.8 88.7 145.4 83.9 139.0 80.4 133.4 76.9 115.5 42.2 38.5 33.8
33.0 112,629 158.6 91.5 149.9 86.5 143.3 82.9 137.6 79.3 119.1 43.5 39.7 34.8
34.0 116,042 163.4 94.3 154.4 89.1 147.6 85.4 141.8 81.7 112.7 44.8 40.9 35.9
35.0 119,455 168.2 97.1 158.9 91.7 151.9 87.9 146.0 84.1 126.4 46.1 42.1 36.9
36.0 122,868 173.0 99.9 163.4 94.3 156.2 90.4 150.2 86.5 130.0 47.4 43.3 38.0
37.0 126,281 177.8 102.7 167.9 96.9 160.5 92.9 154.4 88.9 133.6 48.7 44.5 39.0
38.0 129,694 182.6 105.5 172.4 99.5 164.8 95.4 158.6 91.3 137.2 50.0 45.7 40.1
39.0 133,107 187.4 108.3 176.9 102.1 169.1 97.9 162.8 93.7 140.7 51.3 46.9 41.1
40.0 136,520 192.2 111.1 181.4 104.7 173.4 100.4 167.0 96.1 144.4 52.6 48.1 42.2
41.0 139,933 197.0 113.9 185.9 107.3 177.7 102.9 171.2 98.5 148.0 53.9 49.3 43.2
42.0 143,346 201.8 116.7 190.4 109.9 182.0 105.4 175.4 100.9 151.6 55.2 50.6 44.3
43.0 146,759 206.6 119.5 194.9 112.5 186.3 107.9 179.6 103.3 155.2 56.5 51.8 45.3
44.0 150,172 211.4 122.3 199.4 115.1 190.6 110.4 183.8 105.7 158.8 57.8 53.0 46.4
45.0 153,585 216.2 125.1 203.9 117.7 194.9 112.9 188.0 108.1 162.5 59.1 54.2 47.4
46.0 156,998 221.0 127.9 208.4 120.3 199.2 115.4 192.2 110.5 166.1 60.4 55.4 48.5
47.0 160,411 225.8 130.7 212.9 122.9 203.5 117.9 196.4 112.9 169.7 61.7 56.6 49.5
48.0 163,824 230.6 133.5 217.4 125.5 207.8 120.4 200.6 115.3 173.3 63.0 57.8 50.6
49.0 167,237 235.4 136.3 221.9 128.1 212.1 122.9 204.8 117.7 176.9 64.3 59.0 51.6
50.0 170,650 240.2 139.1 226.4 130.7 216.4 125.4 209.0 120.1 180.5 65.6 60.2 52.7
51.0 174,063 245.0 141.9 230.9 133.3 220.7 127.9 213.2 122.5 184.1 66.9 61.4 53.7
52.0 177,476 249.8 144.7 235.4 135.9 225.0 130.4 217.4 124.9 187.7 68.2 62.6 54.8
53.0 180,889 254.6 147.5 239.9 138.5 229.3 132.9 221.6 127.3 191.3 69.5 63.8 55.8
54.0 184,302 259.4 150.3 244.4 141.1 233.6 135.4 225.8 129.7 194.9 70.8 65.0 56.9
55.0 187,715 264.2 153.1 248.9 143.7 237.9 137.9 230.0 132.1 198.6 72.2 66.2 57.9
56.0 191,128 269.0 155.9 253.4 146.3 242.2 140.4 234.2 134.5 202.2 73.5 67.4 58.8
57.0 194,541 273.8 158.7 257.9 148.9 246.5 142.9 238.4 136.9 205.8 74.9 68.6 59.9
58.0 197,954 278.6 161.5 262.4 151.5 250.8 145.4 242.6 139.3 209.4 76.2 69.8 60.9
59.0 201,367 283.4 164.3 266.9 154.1 255.1 147.9 246.8 141.7 213.0 77.5 71.0 62.3
60.0 204,780 288.2 167.1 271.4 156.7 259.4 150.4 251.0 144.1 216.6 78.8 72.2 63.0
Note: All custom built products are subject to 100% cancellation/
restock charges.
3
Electric Heat Comfort Zones
*”R”values are industry standards for insulation effectiveness. Ask company representative for assistance if you do not know “R” for your present structure insulation.
INSULATION
R-VALUE Recommended FHA Standard Minimum: Not Recommended
Ceiling *R-24 *R-19 *R-11
Walls R-13 11 R-7
Floor R-24 11 ----
ZONE APPROXIMATE WATTAGE NEED PER SQUARE FOOT
1 8.6 10.0 14.6
2 7.7 9.0 13.1
3 7.1 8.2 12.0
4 6.4 7.4 10.8
5 6.0 7.0 10.2
Baseboard or wall mount style? Recessed or surface type? It’s easy to select the heater that’s right for you.
1. Measure the size of the room(s) or area you intend to heat for square footage. You will need the length times the width to
get this calculation.
2. Find your location on the map above. This determines your basic heating zone.
3. The chart shown below the map lists insulation values based on the effectiveness of the insulation presently in your home.
Find your heating zone on the chart and the approximate wattage per square foot you will need.
4. Multiply the total number of square feet you intend to heat by the approximate wattage per square foot you just obtained.
This will determine your total heating requirement in watts for the room.
How Much Heat is Right For You?
Figures are based on 15% total window and door openings in outside walls, and 3/4 total home air changes per hour.
Typical frame-type construction with unheated basement or unventilated crawl space.
If you do not have storm doors and windows, add 30% to the watts per square foot (multiply by 1.3).
That’s all there is to it! Now choose the heater with a wattage equal to what you need. Your nal selection will, of course,
depend on available wall space, window placement, ect.
Sample Calculation:
Example = 10’ x 12’ room in Zone 3 with FHA standard insulation
1. Determine room square footage: 10’ x 12’ = 120 sq. ft.
2. Zone 3 with FHA standard insulation requires 8.2 watts per sq. ft.
3. Multiply square footage of room to be heated by the approximate wattage per square foot required.
120 sq. ft x 8.2 watts = 984 watts required.
From this calculation it can be reasoned that a 1000 watt heater would be required.
4
HLA Series Hazardous Location Fan Forced Unit Heater
FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR T-3B CLASS I, GROUP C & D,
DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2.
Shown with optional pilot
light and disconnect switch
Heat Exchanger and Elements:
Heavy walled, painted carbon steel with aluminum ns liquid heat exchanger, liquid lled with three-immersion type copper
sheathed elements. The elements shall have the highest quality nickel-chromium resistance wire encased in a magnesium oxide
dielectric and be hermetically sealed into the heat exchanger core. The heat transfer uid is Ethylene-glycol solution for operation
to -49 degrees F (– 45 degrees C). Stainless steel and aluminum pressure relief valve for overpressure.
Thermal Cutout High Limit Protection and Optional Pilot Light:
The capillary type manual reset thermal cutout shall be rated for 6000 cycles of service and mounted in the liquid lled heat
exchanger. An optional pilot light to indicate manual reset tripped, if safe operating temperatures are exceeded, is located on
control enclosure.
Motor:
The motor shall be a permanent split capacitor type, permanently lubricated, ball bearing type. The motor shall be rated for
hazardous location and operate at rated voltage of heater, 60 Hz, 1725 RPM.
Control Enclosure:
All controls shall be factory installed and wired in a hazardous location enclosure. Contactors and back-up contactors are heavy
duty type and break all ungrounded conductors and be rated for 100,000 cycles at full load. Standard 24-Volt control circuit shall
be supplied by internal class II transformer. An optional factory wired integral thermostat or standard terminal block for eld
wiring to optional remote wall thermostat are wired in control panel. No fan delay relay.
Disconnect Switch:
Factory mounted and wired hazardous location disconnect switch is available as optional accessory.
Cabinet With Adjustable Louvers:
The Cabinet shall be 14 gauge, cold rolled steel with powder coated epoxy nish. Plated fan guards with less than 1/4 inch
spacing to cover motor and fan shall conform to OSHA Requirements.
Note:
Before selecting a hazardous location electric heater refer to Article 500 or other applicable standard referenced in the National
Electric Code.
Product Specications
• Designed for rugged industrial applications in hazardous locations
where the possibility of explosion or re exists due to the presence of
certain ammable gases, vapors, powdered metals or dust.
• Permanently sealed, liquid to air, nned tube heat exchanger core.
• Ethylene Glycol to water mixture used as a heat transfer uid in the
heater core, providing -45° C. (-49° F) freeze damage protection.
• High-performance electric motor driven fan blows air across nned
tubes to effect uniform heat transfer and area heat distribution.
• Manual Reset capillary type limit provides high temperature regulation
and is rated for 6,000 cycles of service.
• Stainless steel and aluminum pressure relief valve for overpressure.
• A back-up contactor is included for additional protection.
• 14 gauge steel cabinet powder coated epoxy paint nish contains heater
core, motor, and fan assembly.
• Narrow gap safety fan guard shields all moving parts.
• Adjustable louvers allow directional control of air.
• Copper conductor wires enclosed in rigid metal conduits carry all
electrical power.
• Box lugs furnished for eld connections within approved enclosure.
Manufactured in U.S.A.
Liquid-to-air heat exchanger Optional built-in thermostat Hazardous Location Rated Motor
5
HLA Series Hazardous Location Fan Forced Unit Heater
Rating Denitions
CLASS I: Equipment does not have surface operating temperature in excess of the ignition temperature of the specic gas or vapor.
Application Examples:
• Offshore and land based drilling rigs, petroleum exploration and testing facilities.
• Petroleum reneries, gasoline storage and dispensing areas.
• Industrial rms that use ammable liquids in dip tanks for parts cleaning or other operations.
• Petrochemical companies that manufacture chemicals from gas or oil.
• Dry cleaning facilities where vapors from cleaning uids may be present.
• Aircraft hangers and fuel servicing areas.
• Utility gas plants and operations involving storage and handling of liqueed petroleum or natural gas.
GROUP C: Atmospheres such as but not limited to acetaldehyde, allyl alcohol, hydrogen sulde, ethylene, carbon monoxide, or
other gases or vapors of equivalent hazard.
GROUP D: Atmospheres such as but not limited to acetone, alcohol, gasoline, lacquer solvent vapors, natural gas, propane or
other gases or vapors of equivalent hazard.
CLASS II: Equipment does not have surface temperature greater than the ignition temperature of the specied dust.
Application Examples:
• Coal preparation plants and other carbon handling or processing areas.
• Grain elevators, our and feed mills.
• Plants which manufacture, use or store Magnesium or Aluminum powders.
• Plants that have chemical or metallurgical processes.
• Producers of starch products or candy.
• Spice grinding plants, sugar plants and cocoa plants.
GROUP E: Atmosphere containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard
characteristics having resistivity of less than 105 OHM - Centimeter.
GROUP F: Atmosphere containing carbon black, charcoal, coal or coke dust.
GROUP G: Atmospheres containing combustible dust having resistivity of 105 OHM-Centimeter or greater.
DIVISION I: A location in which ignitable concentrations of ammable material exist under normal operating conditions.
DIVISION II: Locations in which ammable materials will normally be conned within closed containers and escape only in the
case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically
also approved for Division II.
Standard Hazardous Location Models
UPC#
686334 MODEL KW BTU’s VOLTS PH AMPS Control
Voltage
Temp
Rise °F
Air
Throw CFM Recom’d
Mounting Ht. WT.
734356 HLA 12-208160-3.0-24
3 10250
208 1 16.3
24
16.5
24’ 580
8’ 167 lb.
734004 HLA 12-208360-3.0-24 208 3 9.8
734011 HLA 12-240160-3.0-24 240 1 14.8
734028 HLA 12-240360-3.0-24 240 3 8.6
734035 HLA 12-480360-3.0-24 480 3 4.3
734363 HLA 12-208160-5.0-24
5 17100
208 1 26
27.6 8’ 167 lb.
734059 HLA 12-208360-5.0-24 208 3 15.4
734066 HLA 12-240160-5.0-24 240 1 23.1
734073 HLA 12-240360-5.0-24 240 3 13.4
734080 HLA 12-480360-5.0-24 480 3 6.7
734370 HLA 12-208160-7.5-24
7.5 25600
208 1 38
41.4 8’ 167 lb.
734103 HLA 12-208360-7.5-24 208 3 22.3
734110 HLA 12-240160-7.5-24 240 1 33.6
734127 HLA 12-240360-7.5-24 240 3 19.4
734134 HLA 12-480360-7.5-24 480 3 9.7
734158 HLA 16-208360-10.0-24
10 34150
208 3 29.3
21.7 40’ 1500 10’ 193 lb.
734165 HLA 16-240160-10.0-24 240 1 44
734172 HLA 16-240360-10.0-24 240 3 25.5
734189 HLA 16-480360-10.0-24 480 3 12.7
734202 HLA 20-208360-15.0-24
15 51200
208 3 43.5
19.2
43’ 2450 13’
193 lb.
734219 HLA 20-240360-15.0-24 240 3 38.1
734226 HLA 20-480360-15.0-24 480 3 19
734233 HLA 20-600360-15.0-24 600 3 15.2
734240 HLA 20-480360-20.0-24 20 68300 480 3 25.1 26.2
225 lb.
734257 HLA 20-600360-20.0-24 600 3 20
734264 HLA 20-480360-25.0-24 25 85400 480 3 31.1 32.8
734271 HLA 20-600360-25.0-24 600 3 24.9
6
Wall or structure
Wall bracket
Mounting arm
Attachment
assembly
Column stabilizing
components
Mounting arm assembly
Attachment assembly
3 1/2” Schedule 40 (Pipe)
(Not Supplied)
Base assembly
1/2” Pipe
(Not Supplied)
Roof or overhead
structure
• SPDT & DPDT Models
• Heat or cool compatible
• Celsius and Fahrenheit temperature scale
• Bi-Metal or capillary sensor
• Snap action switch
• Casting tapped top and bottom for 3/4” conduit
• 1/2” thick cast aluminum housing
• Dimension 5.75” x 6.375” x 5.57”
HLA Series Hazardous Location Fan Forced Unit Heater
Mounting Bracket Kits
HLPM Pipe Mounting Kit
Particularly useful in buildings with
insufcient strength to use other types of
mounts. Requires 3 1/2’’ pipe (4’’ O.D. -
not supplied).
HLWM Wall Mounting Kit
Ideal for use in buildings that have substantial
walls. Arm only can also be bolted directly
to structural steel.
HLHM Hanging Mounting Kit
Simple and economical if adequate overhead
structure exists. Requires 1/2’’ pipe, cut and
threaded (not supplied).
EPET Series and HLT Series Hazardous Location Thermostats For Single Phase
Features
Motor Rating (full load): 3/4 HP @ 125V, 1 1/2 HP @250V
Pilot Duty Rating 125VA @ 24VAC
NEMA Class Seven Div. 1 Approved
Class I Group C & D, Class II Group E, F, & G
Not rated for Group B
HLT Series
UPC#
686334 NUMBER USE WITH
HEATERS W T.
734288 HLPM37 3.0 KW - 7.5 KW 37 lbs.
734295 HLPM1015 10.0 KW 38 lbs.
734301 HLPM1525 15.0 KW - 25.0 KW 40 lbs.
734318 HLHM ALL 5 lbs.
734325 HLWM37 3.0 KW - 7.5 KW 27 lbs.
734332 HLWM10 10.0 KW 28 lbs.
734349 HLWM1525 15.0 KW - 25.0 KW 29 lbs.
UPC#
686334 MODEL DESCRIPTION LOAD RATINGS RANGE
538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF
538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF
528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF
528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF
523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110oF
523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110oF
Master ctn: 4 pcs, 24 llbs (varies slightly by model), 16” x 14.5” x 6”
EPET Series incorporate plastic knob & Bi-Metal Sensor housing.
HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb
and capillary sensor.
7
HLA Series Hazardous Location Fan Forced Unit Heater
Factory Installed Accessories & Physical Dimensions
(Top View)
(Front View)
(Side View)
(Rear View)
MODEL A B CD E F G
3 ph. 1 ph.
HLA 12 17 3/4 22 3/8 19 3/4 20 5/8 16 1/4 10 1/2 14 3
HLA 16 20 3/4 26 3/8 20 3/4 21 5/8 20 1/4 11 1/2 18 4
HLA 20 24 3/4 30 3/8 22 1/2 N/A 24 1/4 12 1/2 22 4 1/2
PHLA Series Portable Hazardous Location Fan Forced Unit Heater
• 3.0 through 25 KW rating
• 208, 240, 480, 600 Volt available in selected capacities
• Cart has anti-static wheels to reduce the risk of static discharge
• Wheeled cart allows for easy maneuverability
• Cart has integrated fork-lift channels to provide ease of lifting on to
ramps or trucks
• Excellent for providing seasonal heating in hazardous environments
• All units have disconnect switch, pilot light, and thermostat - standard
• 24 Volt control, transformer, and contactor in NEMA 7 enclosure
• Durable epoxy coating on heater housing
• Hazardous location unit mounted male / female plug
• Adjustable louvers; manual reset
Standard Portable Hazardous Location Models
SUFFIX DESCRIPTION
T In-Built single pole thermostat 50° - 90° F
120 Control transformer w/ primary fusing (Delete 24 sufx - add 120)
208 208/240V Control available on 208/240V units
(Delete 24 sufx and add 208 OR 240)
240
D Disconnect Switch
P Pilot Light
UPC #
686334 MODEL KW BTU VOLTS PH AMPS TEMP
RISE F
AIR
THROW CFM WT
739344 PHLA12-208160-3.0-24-TDP
3 10,250
208 1 16.3
16.5 24’ 580 260
739337 PHLA12-208360-3.0-24-TDP 208 3 9.8
739320 PHLA12-240160-3.0-24-TDP 240 1 14.8
739313 PHLA12-240360-3.0-24-TDP 240 3 8.6
739306 PHLA12-480360-3.0-24-TDP 480 3 4.3
739436 PHLA12-600360-3.0-24-TDP 600 3 3.5
739290 PHLA12-208160-5.0-24-TDP
5 17,100
208 1 26
27.6 24’ 580 260
739283 PHLA12-208360-5.0-24-TDP 208 3 15.4
739276 PHLA12-240160-5.0-24-TDP 240 1 23.1
739269 PHLA12-240360-5.0-24-TDP 240 3 13.4
739252 PHLA12-480360-5.0-24-TDP 480 3 6.7
739429 PHLA12-600360-5.0-24-TDP 600 3 5.4
739245 PHLA12-208160-7.5-24-TDP
7.5 25,600
208 1 38
41.4 24’ 580 260
739238 PHLA12-208360-7.5-24-TDP 208 3 22.3
739221 PHLA12-240160-7.5-24-TDP 240 1 33.6
739214 PHLA12-240360-7.5-24-TDP 240 3 19.4
739207 PHLA12-480360-7.5-24-TDP 480 3 9.7
739412 PHLA12-600360-7.5-24-TDP 600 3 7.8
739191 PHLA16-208360-10.0-24-TDP
10 34,150
208 3 29.3
21.7 40’ 1500 305
739184 PHLA16-240160-10.0-24-TDP 240 1 44
739177 PHLA16-240360-10.0-24-TDP 240 3 25.5
739160 PHLA16-480360-10.0-24-TDP 480 3 12.7
739405 PHLA16-600360-10.0-24-TDP 600 3 10.2
739153 PHLA20-208360-15.0-24-TDP
15 51,200
208 3 43.5
19.2 43’ 2450 350
739146 PHLA20-240360-15.0-24-TDP 240 3 38.1
739139 PHLA20-480360-15.0-24-TDP 480 3 19
739399 PHLA20-600360-15.0-24-TDP 600 3 15.2
739122 PHLA20-480360-20.0-24-TDP 20 68,300 480 3 25.1 26.2 43’ 2450 350
739382 PHLA20-600360-20.0-24-TDP 600 3 20
739115 PHLA20-480360-25.0-24-TDP 25 85,400 480 3 31.1 32.8 43’ 2450 350
739375 PHLA20-600360-25.0-24-TDP 600 3 24.9
8
FEP Series Single Phase Hazardous Location Wall Convector
Unit with in-built EPET line voltage thermostat
(Sufx T1 or T2)
Unit with optional control section containing
disconnect, pilot light, and thermostat
(Sufx C1-TDP)
Standard Unit
• Cabinet size 18” high, 9” wide.
• Bottom In - Front Out air ow.
• Wall mounting bracket supplied.
• Units cannot be operated in room
ambients exceeding 104
O
F (40
O
C).
• Heavy duty 16 gauge steel with gray
epoxy textured powder coated nish.
• 9” minimum clearance from bottom of
heater to oor required.
• Stainless steel cartridge element inserted
into Aluminum nned Copper sheath.
• Standard unit (without EPET thermostat
or control section) is NEMA 4 rated.
Factory Installed Control Options
*Remove - RA sufx and add new sufx. **Remove - RA sufx and add new sufx (Not NEMA washdown rated or rated for Group B atmospheres)
Sufx “T” is 22 Amps maximum.
Manufactured in U.S.A.
*Items may not be used with 22 Amp line voltage thermostat
T-2A SERIES SINGLE PHASE
Class 1, Group B, C & D Division 1 & 2 280° C / 536° F
UPC MODEL WATTS BTU's VOLTS AMPS CABINET WT.
(LBS.)
686334 LENGTH
445146 FEP-1812-1RA
1800 6143
120 15.0
34” 50
445153 FEP-1820-1RA 208 8.7
445160 FEP-1824-1RA 240 7.5
445177 FEP-1827-1RA 277 6.5
445184 FEP-1848-1RA 480 3.8
445191 FEP-3620-1RA
3600 12286
208 17.3
34” 54
445207 FEP-3624-1RA 240 15.0
445214 FEP-3627-1RA 277 13.0
445221 FEP-3648-1RA 480 7.5
445238 FEP-3657-1RA 600 6.0
445245 FEP-3820-1RA
3800 12969
208 18.3
58” 80
445252 FEP-3824-1RA 240 15.8
445269 FEP-38271-RA 277 13.7
445276 FEP-3848-1RA 480 7.9
445283* FEP-7620-1RA
7600 25938
208 36.5
58” 85
445290* FEP-7624-1RA 240 31.7
445306* FEP-7627-1RA 277 27.4
445313 FEP-7648-1RA 480 15.8
445320 FEP-7657-1RA 600 12.7
T-3A SERIES SINGLE PHASE
Class 1, Group B, C & D Division 1 & 2 180° C / 356° F
445337 FEP-0812-1RA
800 2730
120 6.7
34” 50
445344 FEP-0820-1RA 208 3.8
445351 FEP-0824-1RA 240 3.3
445368 FEP-0827-1RA 277 2.9
445375 FEP-0848-1RA 480 1.7
445382 FEP-1612-1RA
1600 5460
120 13.3
34” 54
445399 FEP-1620-1RA 208 7.7
445405 FEP-1624-1RA 240 6.7
445412 FEP-1627-1RA 277 5.8
445429 FEP-1648-1RA 480 3.3
445436 FEP-1657-1RA 600 2.7
445443 FEP-1712-1RA
1700 5802
120 14.2
58” 80
445450 FEP-1720-1RA 208 8.2
445467 FEP-1724-1RA 240 7.1
445474 FEP-1727-1RA 277 6.1
445481 FEP-1748-1RA 480 3.5
445498 FEP-3420-1RA
3400 11604
208 16.3
58” 85
445504 FEP-3424-1RA 240 14.2
445511 FEP-3427-1RA 277 12.3
445528 FEP-3448-1RA 480 7.1
445535 FEP-3457-1RA 600 5.7
SUFFIX* DESCRIPTION SUFFIX** DESCRIPTION
T1 EPETD8S single pole thermostat factory mounted to
120V - 480V units C1-TD Control section with transformer, 24V contactor, SP thermostat
(40OF - 90OF) and disconnect switch (all units)
T2 EPETD8D double pole thermostat factory mounted to
120V - 480V units C1-TDP Control section with transformer, 24V contactor, SP thermostat
(40OF - 90OF), disconnect switch & pilot light (all units)
9
Unit with optional control section containing
disconnect, pilot light, and thermostat
(Sufx C1-TDP)
Standard Unit
FEP Series Three Phase Hazardous Location Wall Convector
Dimensions: Height 5 5/8’’, Width 6 3/8’’, Depth 4 1/2’’
Finish: Silver-Gray
Type: Single or Double Pole
Remote Mounted Hazardous Location Thermostats For Single Phase Models Only
• Cabinet size 18” high, 9” wide.
• Bottom In - Top Out air ow.
• Wall mounting bracket supplied.
• Units can not be operated in room ambients exceeding 104OF (40OC).
• Heavy duty 16 gauge steel with gray epoxy textured powder coated nish.
• 9” minimum clearance from bottom of heater to oor required.
• Stainless steel cartridge element inserted into Aluminum nned Copper sheath.
• Standard unit (without EPET thermostat or control section) is NEMA 4 rated.
Motor Rating: (full load) 1 1/2 HP @ 250V
Rating: 22A @ 125-277VAC; 125VA @ 24VAC
Rated: Class I Group C & D, Class II Group E, F, G
Thermostat is not rated for use in Group B environments.
EPET Series Parameters
HLT Series
• ABS (American Bureau of Shipping) type approved.
*T1 and T2 option not available on 3 phase models
Factory Installed Control Options
**Remove - RA sufx and
add new sufx (Not NEMA
washdown rated or rated for
Group B atmospheres)
Note: C1-TD and C1-TDP are only options available for 3 phase units.
Note: Controls mounted on the left side
only.
T-2A SERIES THREE PHASE
Class 1, Group B, C, & D Divisions 1 & 2 280° C / 536° F
UPC MODEL WATTS BTU's VOLTS AMPS CABINET WT.
(LBS.)
686334 LENGTH
483056 FEP-1820-3RA
1800 6143
208 5.0
34” 50483063 FEP-1824-3RA 240 4.3
486224 FEP-1848-3RA 480 2.2
483070 FEP-3620-3RA
3600 12286
208 10.0
34” 54483087 FEP-3624-3RA 240 8.7
486231 FEP-3648-3RA 480 4.3
483094 FEP-3820-3RA
3800 12969
208 10.5
58” 80483100 FEP-3824-3RA 240 9.1
486248 FEP3848-3RA 480 4.6
483117 FEP-7620-3RA
7600 25938
208 21.1
58” 85483124 FEP-7624-3RA 240 18.3
486255 FEP-7648-3RA 480 9.2
T-3A SERIES THREE PHASE
Class 1, Group B, C & D Division 1 & 2 180° C / 356° F
483131 FEP-0820-3RA
800 2730
208 2.2
34” 50483148 FEP-0824-3RA 240 1.9
486262 FEP-0848-3RA 480 0.9
483155 FEP-1620-3RA
1600 5460
208 4.4
34” 54483162 FEP-1624-3RA 240 3.8
486279 FEP-1648-3RA 480 1.9
483179 FEP-1720-3RA
1700 5802
208 4.7
58” 80483186 FEP-1724-3RA 240 4.1
486286 FEP-1748-3RA 480 2.0
483193 FEP-3420-3RA
3400 11604
208 9.4
58” 85483209 FEP-3424-3RA 240 8.2
486293 FEP-3448-3RA 480 4.1
UPC#
686334 MODEL DESCRIPTION LOAD RATINGS RANGE
538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF
538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF
528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF
528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF
523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110oF
523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110oF
Master ctn: 4 pcs, 24 lbs (varies slightly by model), 16” x 14.5” x 6”
EPET Series incorporates plastic knob & Bi-Metal Sensor housing.
HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External bulb and capillary sensor.
SUFFIX** DESCRIPTION
C1-TD Control section with transformer, 24V contactor, SP thermostat (40OF - 90OF) and disconnect switch (all units)
C1-TDP
Control section with transformer, 24V contactor, SP thermostat (40
O
F - 90
O
F), disconnect switch & pilot light (all units)
10
A
E
C
FIG. 2
HG
B
FIG. 1
FIG. 3
D
F
Rear View
Control Panel
A5520
3-15 Kw ONLY
W5550
Ideal for use in buildings
that have substantial
walls. Arm (only) can
be bolted directly to
structural steel.
WALL BRACKET
MOUNTING
ARM
WALL OR STRUCTURE
H5550
Simple and economical if
adequate overhead
structure exists. Requires
1/2" pipe, cut and threaded
(not supplied).
ROOF OR OVERHEAD
STRUCTURE
1/2" PIPE
(NOT SUPPLIED) 3 1/2" SCHEDULE 40 PIPE
(NOT SUPPLIED)
BASE
ASSEMBLY
MOUNTING
ARM ASSY.
COLUMN STABILIZING
COMPONENETS
Particularly useful in
buildings with
insufficient strenth to
use other types of
mounts.
Requires 3 1/2" pipe
(4" O.D.-not supplied).
P5550
The Washdown Series unit heaters are electric unit heaters constructed
for use in areas that require washing or hosing of equipment due to
dirty or dusty industrial environments in non-hazardous locations. The
totally enclosed water-tight construction made with corrosion-resistant
material make this series ideal for industrial heating applications. The
Washdown Series is constructed with all built-in controls and safety
temperature controls wired in a non-metallic Nema 4x control panel
with single-point power connections.
Mounting Bracket Kits & Product Dimensions
• Heavy-duty 304 16 gauge stainless steel shroud.
• 316 stainless construction available.
• Nema 4x non-metallic control panel.
• 24-Volt transformer and control panel.
• 3-position switch (off-heat-fan).
• Capillary thermostat with stainless steel sensor.
• Automatic reset thermal cutout.
• Totally enclosed U.L. listed motor.
• Pilot light (power on indicator).
* Material: Heavy Duty Epoxy Powder Coat Finish.
•
Stainless steel nned tubular element. Constructed of 304 or 316 stainless rod and ns.
• Control panel on bottom of unit for ease of installation and service.
• Disconnect switch with enclosure door interlock.
• Front grill rotates to direct airow.
• Single-point power connection.
• Fan Blade Epoxy coated Aluminum.
• Epoxy painted cold roll steel model available
- consult factory.
• Meets all U.L., NEC, and OSHA requirements
(when installed as directed).
• Corrosion-resistant in high humidity and water-saturated areas (for areas
where corrosion resistance is needed in non-explosive areas, contact
factory for heater applications and optional materials).
• ABS (American Bureau of Shipping) type approved.
• Thermostat temp range: 40o-100oF
Manufactured in U.S.A.
Heater
KW
Heater Dimension in Inches unless otherwise stated.
A B C D E F G H
3-7.5 12.00 18.00 19.75 15.25 16.25
6 ft.
8.00 6.00
10-15 14.00 19.00 21.75 15.25 18.00 8.00 6.00
20-30 16.00 27.00 28.75 19.50 17.50 15.50 4.50
40-48 18.00 31.00 30.75 19.50 19.50 21.75 2.75
SIZE
KW
UPC#
686334
STAINLESS STEEL
COMBINATION BRACKET
UPC#
686334
WALL MTG.
BRACKET *
UPC#
686334
HANGING
BRACKET *
UPC#
686334
PIPE MTG.
BRACKET *
3.3-15 725729 A5520/UHB 713726 W5520/WMK 713702 H5520/HMK 713689 P5520/PMK
20-48 ---- 713733 W5550/WMK 713719 H5550/HMK 713696 P5550/PMK
WD Series Washdown Fan Forced Unit Heater
11
Product Specications & Standard Washdown Models
Remote Rain-Tight Thermostat
Enclosure and Motor:
Element housing shall be 16
gauge 304 or 316 stainless
steel shroud. The outlet grill
and louver assembly shall
be 304/316 stainless steel
and rotate for direction of
discharge air. The heater shall
have a 304/316 stainless steel
inlet grill and fan guard. The
motor shall be totally enclosed,
permanently lubricated and
designed to resist moisture
and corrosion. The fan blade
shall be aluminum with a
powder coated epoxy nish.
Element: The heating
element shall be 304 or 316
stainless steel tube with
304/316 stainless steel n
material helically attached to
the tube for even heat transfer.
The element designed with
the highest quality nickel-
chromium resistance wire
embedded in compacted
efcient dielectric to ensure
proper heat transfer.
Control Panel: The control
enclosure shall be non-metallic
Nema 4X control panel water-
tight and dust- tight. The
enclosure and elements are
attached to the control panel
with stainless steel fasteners.
Standard control components
are factory mounted and wired
with access through control
panel door on bottom of heater
assembly. A standard door
interlock disconnect switch
shall be factory mounted and
wired for safety.
Controls: All controls shall
be factory mounted and
wired in Nema 4X panel.
Terminal block, 24 Volt
transformer, high temperature
limits, contactor and fusing if
required by NEC are mounted
and wired in control panel. A
three-position switch (Off-
Heat-Fan) shall be mounted
on side of control panel for
access from outside of panel.
A pilot light to indicate
power is on for safety shall
be located on side of control
panel. A wall mounted Nema
4X thermostat is an optional
accessory.
Mounting Bracket: A
formed 304/316 stainless steel
bracket shall be used on 3.3
thru 15 KW units. A cast iron
epoxy painted bracket shall
be used on 20 thru 48 KW
units. Above brackets shall be
combination wall/ceiling type.
Optional mounting brackets
are available.
Note: NEMA 4X Construction Stainless Steel Hardware
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
UPC#
686334 MODEL DESCRIPTION
523424 TW155A 1 POLE, 40-110 deg F, 22Amp
523431 TW255A 2 POLE, 40-110 deg F, 22Amp
WD Series Washdown Fan Forced Unit Heater
UPC#
686334 MODEL KW BTU’s VOLTS PH AMPS CONTROL
VOLTAGE
TEMP
RISE °F
AIR
THROW CFM WT.
(LBS.)
713047 81WD3T01
3.3 11200
208 1 15.9
24
26
20’ 400 58
713054 82WD3T01 208 3 9.2
713061 21WD3T01 240 1 13.7
713078 22WD3T01 240 3 7.9
713085 71WD3T01 277 1 11.9
713092 43WD3T01 480 3 4
713115 81WD5T01
5 17100
208 1 24.1
40
713122 82WD5T01 208 3 13.9
713139 21WD5T01 240 1 20.8
713146 22WD5T01 240 3 12.1
713153 71WD5T01 277 1 18.1
713160 43WD5T01 480 3 6.1
713184 81WD7T01
7.5 25600
208 1 36.1
60
713191 82WD7T01 208 3 20.8
713207 21WD7T01 240 1 31.3
713214 22WD7T01 240 3 13.1
713221 71WD7T01 277 1 27.1
713238 43WD7T01 480 3 9.1
713252 81WD10T01
10 34130
208 1 47.8
45
28’ 700 64
713269 82WD10T01 208 3 27.7
713276 21WD10T01 240 1 41.2
713283 22WD10T01 240 3 24.1
713290 71WD10T01 277 1 36.1
713306 43WD10T01 480 3 12.1
713399 81WD15T01
15 51200
208 1 72.1
68
713405 82WD15T01 208 3 41.7
713412 21WD15T01 240 1 62.5
713429 22WD15T01 240 3 36.1
713443 43WD15T01 480 3 18.1
713467 83WD20T01
20 68260
208 3 55.6
45
35’ 1400 92
713474 23WD20T01 240 3 48.2
713481 43WD20T01 480 3 24.1
713504 83WD25T01
25 85325
208 3 69.5
56713511 23WD25T01 240 3 60.2
713528 43WD25T01 480 3 30.1
713542 83WD30T01
30 102390
208 3 83.4
68713559 23WD30T01 240 3 72.3
713566 43WD30T01 480 3 36.1
713603 43WD40T01 40 136520 480 3 48.2 70 42’ 1800 126
713641 43WD48T01 48 163824 480 3 57.8 84
12
BA
A
BBA
3.3 KW THROUGH 15 KW UNIT HEATERS 20 KW THROUGH 48 KW UNIT HEATERS
HOW TO DESIGNATE A MODEL:
H 2 H UH 10 C A 1
Element Volts
F = 208
H = 240
HF = 240/208
G = 277
P = 480
Phase
1 = 1-Phase
2 = 1 or 3-Ph.
3 = 3-Phase
Motor Voltage
F = 208
H = 240
B = 240 / 208
G = 277
P = 480
Model Series
UH
Element KW Control System
O = None
C = Contactor
R = Relay
Transformer
O = None
A = Included
Control Volts
1 = 24
2 = 120
3 = Element Voltage
4 = 240
Factory Installed Options (use as a suffix on model designation):
S = Summer Fan Switch, F = Fan Delay, D = Disconnect, T = Built-in Thermostat, E = Epoxy Coated
Field Installed Options:
Disconnect Switch, Built-in Thermostat, & Wall / Ceiling Bracket
UH Series Horizontal Fan Forced Unit Heater
NOTE: Louver assembly is square and mounted with
screws. Louver can be removed and repositioned for four
(4) directional air ow - left - right - up - down with the
heater in the horizontal position.
3.3 KW THROUGH 48 KW HORIZONTAL DISCHARGE SUSPENDED FAN FORCED UNIT HEATERS
AVAILABLE IN 1 OR 3 PHASE FOR ALL STANDARD VOLTAGES FROM 208V TO 480V.
Product Dimensions & Model Number Designation
Figures 3 & 4 shown with standard mounting tabs for units over 20 KW. Optional UHB-3 and UHB-4 wall brackets are available. 3.3 KW
thru 15 KW units can be mounted using 1/4” threaded rod. 20 KW thru 48 KW units can be mounted using 5/16” threaded rod.
CONSTRUCTION:
Heavy gauge welded steel cabinet with powder coated nish and control
compartment with a hinged and latched access door, simplifying wiring
installation & maintenance.
HEATING ELEMENT:
Circular copper clad steel sheath element with continuously brazed steel ns
formed to match the air delivery pattern of the fan blade.
OVERHEAT PROTECTION:
All units come equipped with automatic resetting type limit controls to de-
energize the heater should an over-temperature situation occur.
FAN and MOTOR:
Totally enclosed, single phase, permanently lubricated, thermally protected
motors with unit bearings on 3 KW - 10 KW models and sleeve bearings on 12.5
KW - 48 KW models - mounted with rubber insulators to minimize vibration and
noise. Fan assembly enclosed by a heavy gauge, close spaced, chrome plated
wire guard.
LOUVER ASSEMBLY:
Louvers are individually adjustable for directional control of air ow and the
entire assembly can be repositioned in the eld from down ow to up ow or
left / right directional air ow.
TEMPERATURE CONTROLS:
20 KW through 48 KW units and all 480V have built in 24 Volt transformer
for low voltage remote thermostat application. 25 KW through 48 KW models
available in 2-stage on special order (consult factory).
INSTALLATION:
Unit Heaters can be mounted with the motor shaft from horizontal to downward
at 45° off horizontal. Pre-drilled holes and installed threaded nuts provided to
allow hanging by threaded rods - 1/4” for units up to 15 KW and 5/16” for 20
KW units and larger. Optional wall / ceiling mounting brackets are available for
all units.
FACTORY INSTALLED OPTIONS:
• 24 Volt transformer on 3 KW to 15KW units to
convert from line voltage to low voltage remote
thermostat operation.
• Summer fan switch to operate the fan only.
• Fan delay switch to purge all residual heat from the
unit after the heating element has cycled off.
• Powder coated epoxy nish for corrosive atmospheres.
• Disconnect switch.
Manufactured in U.S.A.
Dimensions A B C
Figure 1:
3.3, 5, 7.5, 10 KW 20” 11” 13”
Figure 2:
12.5, 15 KW 22” 11” 15”
Figure 3:
20, 25, 30 KW 24” 17” 17”
Figure 4:
40, 48 KW 26” 23” 19”
MAXIMUM RECOMMENDED MOUNTING
HEIGHT
3 - 10 KW 9 FT.
12 - 15 KW 10 FT.
20 - 30 KW 13 FT.
40 - 48 KW 16 FT.
13
UH Series Horizontal Fan Forced Unit Heater
Standard Product Models
Factory & Field Installed Accessories
NOTE: Factory installed heat purge fan delay option (F) requires
unit to have CA1 or CA2 factory installed
FACTORY INSTALLED OPTIONS
SUFFIX DESCRIPTION
F
Heat purge fan delay switch for 208 / 240 / 277V units
(includes contactor & transformer)
Heat purge fan delay switch for 480V units
(contactor & transformer standard in unit)
S Summer fan switch
CA1 24V Transformer (3.3 KW - 15 KW units) & Contactor
CA2 120V Transformer (3.3 KW - 15 KW units) & Contactor
EEpoxy Coating
TSPST Thermostat
D
Disconnect Switch - 30 Amps
Disconnect Switch - 40 Amps
Disconnect Switch - 80 Amps
Disconnect Switch - 100 Amps
FIELD INSTALLED ACCESSORIES
UPC# MODEL DESCRIPTION
686334
646239 DCS303 30 Amp Disconnect Kit
646246 DCS403 40 Amp Disconnect Kit
646253 DCS803 80 Amp Disconnect Kit
646260 DCS1003 100 Amp Disconnect Kit
687997 TUH1 25 Amp SPST Thermostat Kit
699105 UHB-1 wall / ceiling bracket - 3.3 KW - 15 KW units
699112 UHB-3 wall / ceiling bracket - 20 KW - 30 KW units
699129 UHB-4 wall / ceiling bracket - 35 KW - 48 KW units
UPC#
686334 MODEL KW BTU'S VOLTS PH AMPS CONTROL
VOLTS
TEMP
RISE °F
AIR
THROW CFM
RECOM'D
MOUNTING
HT.
WT.
(LBS.)
644600 F1FUH03003
3.3 11,200
208 1 16 208
26 26' 400
9'
36
644662 H1HUH03003 240 1 14 240
644723 G1GUH03003 277 1 12 277
711487 H3HUH03C03 240 3 8 240
711494 F3FUH03C03 208 3 9 208
711401 P3PUH03CA1 480 3 4 24
644617 F1FUH05003
5 17,100
208 1 24 208
40 26' 400
36644679 H1HUH05003 240 1 21 240
644730 G1GUH05003 277 1 18 277
644938 F2FUH05C03 208 1 or 3 24.1/14.0 208
44644945 H2HUH05C03 240 1 or 3 20.8/12.1 240
644884 P3PUH05CA1 480 3 6 24
644624 F1FUH07CA1
7.5 25,600
208 1 36 24
42 36' 575
40
688550 H1HUH07CA1 240 1 31 24 41
644747 G1GUH07CA1 277 1 27 24 41
644792 F3FUH07C03 208 3 21 208
44644952 H2HUH07C03 240 1 or 3 31.3/18.1 240
644891 P3PUH07CA1 480 3 9 24
644631 F1FUH10CA1
10 34,100
208 1 48 24
55
36' 575
42
644693 HIHUH10CA1 240 1 42 24
644754 G1GUH10CA1 277 1 36 24
644969 F2FUH10C03 208 1 or 3 48.1/27.8 208
644976 HF2HUH10C03 10/7.5 34,100 240 1 or 3 41.7/24.1 240 55 45
25,600 208 1 or 3 36.1/20.8 208 42
711425 P3PUH10CA1 10 34,100 480 3 12 24 55 51
644648 F1FUH12C03
12.5 42,600
208 1 60 208
49 45' 800
10'
45
644709 H1HUH12C03 240 1 52 240
644815 F3FUH12C03 208 3 35 208
644860 H3HUH12C03 240 3 30 240
711432 P3PUH12CA1 480 3 15 24
644655 F1FUH15CO3
15 51,200
208 1 72 208
59 45' 800 54
644716 H1HUH15C03 240 1 63 240
644822 F3FUH15C03 208 3 42 208
644877 H3HUH15C03 240 3 36 240
711449 P3PUH15CA1 480 3 18 24
688307 F1FUH20CA1
20 68,300
208 1 96 24
47 56' 1350
13'
55
688420 H1HUH20CA1 240 1 83 24
688314 F3FUH20CA1 208 3 56 24
688437 H3HUH20CA1 240 3 48 24
688321 P3PUH20CA1 480 3 24 24
688444 F1FUH25CA1
25 85,300
208 1 120 24
58 56' 1350 55
688338 H1HUH25CA1 240 1 104 24
688451 F3FUH25CA1 208 3 70 24
688345 H3HUH25CA1 240 3 60 24
688468 P3PUH25CA1 480 3 30 24
688475 H1HUH30CA1
30 102,390
240 1 125 24
70 56' 1350 60
688369 F3FUH30CA1 208 3 83 24
688482 H3HUH30CA1 240 3 72 24
688376 P3PUH30CA1 480 3 36 24
688406 P3PUH40CA1 40 136,500 480 3 48 24 55 56' 2275 16' 75
688789 P3PUH48CA1 48 163,800 480 3 58 24 67 56' 2275 78
14
D
H
W
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
3.3 KW THROUGH 50 KW SUSPENDED FAN FORCED UNIT HEATERS AVAILABLE IN 1 OR 3 PHASE FOR ALL STANDARD
VOLTAGES FROM 208V TO 480V THAT CAN BE MOUNTED TO PROVIDE HORIZONTAL OR VERTICAL DISCHARGE.
Vertical Discharge
Horizontal Discharge
FIELD INSTALLED OPTIONS:
• In-unit or wall mounted
temperature control thermostats
low or line voltage.
• Summer fan switch to operate
the fan only.
• Power disconnect switch.
• Heat stratication thermostat.
Installing the Taskmaster Series
DETERMINING HEATER REQUIREMENTS
Calculate the heating loads using the NEMA handbook or ASHRAE guide. Then determine the quantity and
size of unit heaters to be used. To maintain uniform heat and reduce stratied air, it is recommended that the
total CFM of the units turn the air over approximately 3 times per hour. In instances where a large group of
people are located and normally in the same area, use a large number of lower KW unit heaters. In warehouse
areas or storage rooms where heat distribution and constant temperatures are less important, use fewer heaters
of higher capacity.
HORIZONTAL MOUNT
Small rooms can be heated by one unit heater. Where two walls are exposed, heaters should be mounted as
shown in Figure A. In larger rooms, units should he located so their air streams wipe exposed walls without
blowing at them. Units should be located so that the air stream of one supports that of another thus setting
up a circulatory air movement shown in
Figure
B. (Distance between units to be approximately 1-1/2 times
published air throw.) Units should not be mounted horizontally in areas having ceiling heights in excess of
15-18 ft.
VERTICAL MOUNT
Units should be mounted vertically in high bay areas, or where heater location would not interfere with plant
operation or trafc, Heaters should be situated to provide free air circulation. Size and selection of units should
be based on recommended mounting height. Optional diffusers may best be employed to reduce high air
velocity and at the same time disperse heated air in a uniform pattern. When unit heaters are used to combat
cold air inrush from opened loading dock doors, one or more units should be arranged to blow warm air across
opening (Figure C).
DUAL MOUNTING
Where square footage is large and comfort essential, both horizontal and vertical installations may best serve
your requirements as Figure D demonstrates.
Taskmaster Dimensions
CONSTRUCTION:
Heavy 18 gauge welded steel cabinet with powder coated nish and control compartment housing
a master terminal board with a hinged and latched access door, simplifying wiring, installation &
maintenance.
HEATING ELEMENT:
Copper clad steel sheath element
with continuously brazed steel ns
formed to allow side draw through
air ow.
OVERHEAT PROTECTION:
All units come equipped with
automatic reset type limit controls
to de-energize the heater should an
over-temperature situation occur.
FAN and MOTOR:
Totally enclosed, 1-speed, 1-phase, permanently lubricated, thermally protected motors with unit
bearings on 3 KW - 20 KW models. Totally enclosed, 2-speed, 1-phase, permanently lubricated,
thermally protected motors with sleeve bearings on 25 KW - 50 KW models. All motors mounted
with rubber insulators to minimize vibration & noise. Fan over-ride purges unit of residual heat at
shutdown.
LOUVER ASSEMBLY:
Louvers are individually adjustable for directional control of air ow up to 15° from straight
horizontal. Optional diffusers available for down ow (vertical discharge) applications.
TEMPERATURE CONTROLS:
Optional low voltage and line voltage thermostats available with an adjustable temperature range of
40°F to 90°F. Units with model numbers ending in CA1 are factory wired for low voltage controls.
25 KW through 50 KW units are designed for two stage heating operation.
INSTALLATION:
Unit Heaters can be mounted for horizontal or vertical discharge.
Applications up to 6000 Ft. See UH Series above 6000 Ft.
ABS (American Bureau of Shipping) type approved.
Manufactured in U.S.A.
KW
RATING
DIMENSIONS (inches)
HWD
3.3 - 5.0 17 3/4 14 15/32 6 1/2
7.5 - 10.0 24 5/16 21 1/2 6 1/2
15.0 - 20.0 28 11/16 21 1/2 6 1/2
25.0 - 50.0 34 29 1/4 10 1/16
Note: Products in this section with factory installed controls are subject to 100% cancellation/restocking charges.
15
HOW TO DESIGNATE A MODEL:
HF 2 B 51 10 C A 1
Element Volts
F = 208
H = 240
HF = 240/208
G = 277
P = 480
Phase
1 = 1-Phase
2 = 1 or 3-Ph.
3 = 3-Phase
Motor Voltage
F = 208
H = 240
B = 240 / 208
G = 277
P = 480
Model Series
51
Element KW Control System
Blank = None
C = Contactor
Transformer
Blank = None
A = Included
Control Volts
1 = 24
2 = 120
(with CA option)
Description 1 Description 2 Description 3 Description 4
Louver Diffuser No Diffuser Anemostat Diffuser Radial Diffuser
(*Included with
A5100 bracket.)
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
Diffuser Options
Mounting Brackets & Model Designator
Not actual colors. Red & yellow shading is for diagram clarity only.
DESCRIPTION UPC#
686334
MODEL
NUMBER KW USED MAX MOUNTING
HEIGHT (ft.)
DIMENSION
A (feet)
DIMENSION
B (feet)
WT.
(lbs.)
1
Louver Diffuser (Standard). Louvers can
be individually adjusted for rectangular
coverage over doorways as an air curtain,
or to meet rectangular oor pattern heating
requirements.
NA Standard
3.3-5
7.5-10
25-30
40-50
9
12
18
22
24
20
40
52
75
84
10
22
30
42
47
NA
2
General Distribution (No Diffuser). The
5100 air chute venturi permits general down
ow air pattern distribution as required at a
higher mounting height.
NA Not
Required
3.3-5
7.5-10
25-30
40-50
9
12
18
22
24
15
30
40
55
64
NA NA
3
Anemostat Diffuser (Optional). For
applications where draft restriction is
required at lower unit mounting heights.
692687
681186
681186
722070
AD5120
AD5150
AD5150
AD5175
7.5-10
25-30
40-50
60-70
15
17
20
31
38
50
60
-
NA
10
12
37
4
Radial Diffuser (Optional). Individually
adjustable ns permit increased oor
coverage at 45° open. Additional throw is
accomplished when ns are 90° vertical.
(Please allow for higher mounting heights.)
692663
692663
692670
692670
722087
RD5120
RD5120
RD5150
RD5150
RD5175
7.5-20
25-50
60-70
45° 90° 45° 90°
NA
12
10
14
20
18
26
14
21
30
28
36
36
42
62
68
72
30
35
44
54
60
14
39
MOUNTING BRACKETS
UPC# MODEL MODEL SIZE WT.
686334
692694 A5105 3.3 KW TO 5.0 KW 9 lbs.
692700 A5120 7.5 KW TO 20.0 KW 13 lbs.
692717 A5150 25.0 KW TO 50.0 KW 16 lbs.
688628 B5105* 3.3 KW TO 20.0 KW 3 lbs.
688635 B5150* 25.0 KW TO 50.0 KW 8 lbs.
692847 V5105 3.3 KW TO 5.0 KW 9 lbs.
692854 V5120 7.5 KW TO 20.0 KW 13 lbs.
692861 V5150 25.0 KW TO 50.0 KW 16 lbs.
DUST SHIELD
692878 DS5105 3.3 KW TO 5.0 KW 3 lbs.
692885 DS5120 7.5 KW TO 20.0 KW 4 lbs.
681223 DS5150 25.0 KW TO 50.0 KW 5 lbs.
FAN GUARD
706544 OFG5101 3.3 KW TO 5.0 KW 3 lbs.
706551 OFG5102 7.5 KW TO 20.0 KW 4 lbs.
706568 OFG5103 25.0 KW TO 50.0 KW 5 lbs.
16
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
Standard Taskmaster Models & Series Notes
International Models
• For 24V control add “CA1” sufx. • For 120V control add “CA2” sufx. • For other voltages consult factory.
NOTES:
• 25-50KW models are wired for single or two stage heating and have two speed motors.
• Air delivery and motor data on dual voltage units reect higher voltage.
• 600 Volt models available in 5 KW through 30 KW. Contact factory for delivery.
• Supply wire on 40 and 50 KW models should have rated insulation of 75oC minimum.
• Use T5122 for two stage control.
• Use TW123 for two stage control.
• Use TFS5102 for two stage control.
• Wall thermostat must be used when built-in stratication thermostat is required.
UPC#
686334 MODEL KW BTU / H VOLTS PH AMPS CONTROL
VOLTAGE
TEMP
RISE
AIR
THROW CFM
RECOMMENDED
MOUNTING HT. WT.
(LBS.)
Horizontal Vertical
645089 F1F5103N 3.3 11.2 208 1 15.9 208
26oF 12’ 400 9’ 9’ 25
645102 HF1B5103N 3.3/2.5 11.2 / 8.5 240/208 1 13.7 / 11.9 240 / 208
645683 F2F5103N 3.3 11.2 208 1 / 3 11.9 / 6.9 208
645706 HF2B5103N 3.3/2.5 11.2 / 8.5 240/208 1 / 3 13.7 / 11.9 240 / 208
3 7.9 / 6.9
645720 G1G5103N 3.3 11.2 277 1 11.9 277
645126 P3P5103CA1N 480 3 4.0 24
645546 F1F5105N 5.0 17.1 208 1 24.1 208
40oF 12’ 400 9’ 9’
25
645560 HF1B5105N 5.0/3.7 17.1 / 12.8 240/208 1 20.9 / 18.1 240 / 208
645140 F2F5105N 5.0 17.1 208 1 / 3 24.1 208
313.9
645164 HF2B5105N 5.0 17.1 240 1 / 3 20.8 / 18.1 240
27
3.7 12.8 208 1 / 3 12.1 / 10.4 208
645843 G1G5105N 5.0 17.1 277 118.1 277
645188 P3P5105CA1N 5.0 17.1 480 3 6.1 24
645201 F2F5107CA1L 7.5 25.6 208 1 / 3 36.1 / 20.8
24
34°F 22’ 700 10’ 12’ 54
645225 HF2B5107CA1L 7.5 25.6 240 1 / 3 27.1 / 31.3
5.6 19.2 208 1 / 3 31.3 / 27.1
645928 G1G5107CA1L 7.5 25.6 277 1 27.1
645249 P3P5107CA1N 7.5 25.6 480 3 9.1
645263 F2F5110CA1L 9.9 33.8 208 1 / 3 47.8 / 27.4
45°F 22’ 700 10’ 14’ 55
645287 HF2B5110CA1L 10.0 34.1 240 1 / 3 41.2 / 24.0
7.5 25.6 208 1 / 3 36.1 / 20.8
645645 G1G5110CA1N 10.0 34.1 277 1 36.1
645300 P3P5110CA1N 10.0 34.1 480 3 12.1
645324 F3F5115CA1L 15.0 51.2 208 3 41.7
1100 64645348 HF3B5115CA1L 15.0/11.2 51.2 / 38.4 240/208 3 36.1 / 31.3 43°F 32’ 11’ 20’
645362 P3P5115CA1N 15.0 51.2 480 3 18.1
645386 HF3B5120CA1L 19.7/14.8 67.2 / 50.5 240/208 3 47.8 / 41.1 57°F 32’ 1100 12’ 18’ 65
645409 P3P5120CA1N 20.0 68.3 480 3 24.1
645881 F3F5125CA1L 25.0 85.3 208 3 69.5
2000/1800645942 HF3B5125CA1L 25.0/18.7 85.3 / 64.0 240/208 3 60.2 / 52.1 40/44°F 45’ 12’ 22’ 120
645980 P3P5125CA1N 25.0 85.3 480 3 30.1
645423 F3F5130CA1L 30.0 102.4 208 3 83.4
2000/1800645447 HF3B5130CA1L 30.0/22.5 102.4 / 76.8 240/208 3 72.3 / 62.5 47/53°F 40’ 12’ 20’ 120
645461 P3P5130CA1N 30.0 102.4 480 3 36.2
644044 F3F5140CA1L 40.0 136.5 208 3 111.2
644068 HF3B5140CA1L 40.0/30.0 136.5/102.4 240/208 3 96.4 / 83.4 40/45°F 55’ 3100/2800 15’ 24’ 120
644082 P3P5140CA1N 39.0 133.1 480 3 47.0
645485 F3F5150CA1L 49.6 169.3 208 3 139.0
645508 HF3B5150CA1L 50.0/37.5 170.6/128.0 240/208 3 120.5/104.3 51/56°F 50’ 3100/2800 15’ 22’ 120
645522 P3P5150CA1N 50.0 170.6 480 3 60.3
UPC#
686334 MODEL KW BTU/H VOLTS PH AMPS CONTROL
VOLTAGE
TEMP
RISE
AIR
THROW CFM
RECOMMENDED
MOUNTING HT. WT.
(LBS.)
Horizontal Vertical
715300 Q3H5103CA1 3.3 11263 380
3
5.02
24
26
12’ 400 9’ 9’
25
724920 R3H5103CA1 415 4.6
724937 Q3H5105CA1 5.0 17065 380 7.6 40 27
424944 R3H5105CA1 415 6.96
717137 Q3H5107CA1 7.5 25600 380 11.4 34
22’ 700
10’ 12’ 54
724951 R3H5107CA1 415 10.5
686570 Q3H5110CA1 10.0 34130 380 15.2 45 10’ 14’ 55
724968 R3H5110CA1 415 13.9
724975 Q3H5115CA1 15.0 51195 380 22.8 43
32’ 1100
11’ 20’ 64
724982 R3H5115CA1 415 20.9
704175 Q3H5120CA1 20.0 68260 380 30.4 57 12’ 18’ 65
724999 R3H5120CA1 415 27.85
719193 Q3H5125CA1 25.0 85325 380 38.0 40/44 45’
2000/1800
12’ 22’
120
710619 R3H5125CA1 415 34.8
725002 Q3H5130CA1 30.0 102390 380 45.6 47/53 40’ 12’ 20’
710626 R3H5130CA1 415 41.8
725019 Q3H5140CA1 40.0 136520 380 60.85 40/45 55’ 3100/2800 15’ 24’
709835 R3H5140CA1 415 55.7
17
5100 Series Horizontal or Vertical Mounted Fan Forced Unit Heater
Recommended Control Options, Control Accessory Options, & Control Accessories
**Any SPST thermostat of sufcient amperage may be substituted.
*Use DPST thermostat for 3-phase line voltage control in non “C” models.
CONTROL ACCESSORY OPTIONS - FIELD INSTALLED IN HEATER
UPC#
686334 MODEL DESCRIPTION
POWER DISCONNECT SWITCH
717151 DCS202/5100 2 POLE; 20 AMP; 120-277 V.A.C.
717168 DCS403/5100 3 POLE; 40 AMP; 120-600 V.A.C.
717175 DCS603/5100 3 POLE; 60 AMP; 120-600 V.A.C.
717182 DCS1003/5100 3 POLE; 100 AMP; 120-600 V.A.C.
LINE VOLTAGE THERMOSTAT (45 - 90 oF)
692779 T5100 SPST; LINE DUTY 25 AMP 120-277V
692786 T5102 DPST; LINE DUTY 25 AMP 120-277V
LOW VOLTAGE THERMOSTAT (ALL CA1 MODELS) (45 - 90 oF)
692779 T5100 SPST; LOW VOLT/PILOT DUTY; 125VA ; (3.3-20 KW UNITS)
692793 T5122 2-STAGE; LOW VOLT; 125VA; (25-50 KW UNITS)
STRATIFICATION THERMOSTAT
692809 TC5102 SPST; LOW VOLT/PILOT DUTY (W/RELAY) ; 70-130O
692816 TC5103 SPST; LINE DUTY; AMP 120-240V; 70-130O
SUMMER FAN SWITCH
692823 FS5101 SPST; LINE VOLT ;120-277V
692830 FS5102 SPST; LINE VOLT ; 480-600V
CONTROL ACCESSORIES - REMOTE WALL MOUNTED
UPC#
686334 MODEL DESCRIPTION
LINE VOLTAGE THERMOSTAT
691086 **TW1510 SPST; 25 AMP 120-277V 50-90o
691093 *TW1512 DPST; 25 AMP 120-277V 50-90o
LOW VOLTAGE THERMOSTAT (ALL CA1 MODELS)
260008 A6176 SPST; (3.3 - 20 KW UNITS) 50-90O
691116 TW123 2STAGE; (25 - 50 KW UNITS) 40-90O
STRATIFCATION THERMOSTAT
691109 TC1602 LINE VOLT 120-277V 70-140O
SUMMER FAN SWITCH
692625 FSW5111 SPST; LINE VOLT 120-277V
692632 FSW5112 SPST; LOW VOLT (W/RELAY)
LOW VOLTAGE T'STAT & SUMMER FAN SWITCH(W/RELAY) (CA1 MODELS)
692649 TFS5101 SPST; LOW VOLT 50-90O
692502 TFS5102 2 STAGE; LOW VOLT 50-90O
MODEL
NUMBER
DISCONNECT
SWITCH THERMOSTAT SUMMER FAN SWITCH THERMOSTAT &
SUMMER FAN
SWITCH
WALL MOUNTED
STRATIFICATION
THERMOSTAT
1 Ø 3 Ø IN-BUILT WALL
MOUNTED IN-BUILT WALL
MOUNTED IN-BUILT WALL
MOUNTED
F1F5103N
DCS 202 NA T5100 ET5SS
FS5101 FSW5111 NA TC5103 TC1602
HF1B5103N
F2F5103N NA DCS 403 T5102 TW 1512
HF2B5103N DCS 202 NA T5100 ET 5SS
NA DCS 403 T5102 TW 1512
G1G5103N DCS 202 NA
T5100
ET5SS NA
P3P5103CA1N NA DCS 403 A6176 FS5102 FSW5112 TFS5101 TC5102 NA
F1F5105N
DCS 403 NA
S2025
FS5101 FSW5111 NA TC5103 TC1602
HF1B5105N ET5SS
F2F5105N S2025
NA DCS 403 T5102 TW 1512
HF2B5105N DCS 403 NA T5100 ET5SS
NA DCS 403 T5102 TW 1512
G1G5105N DCS 202 NA
T5100
S2025 NA
P3P5105CA1N NA DCS 403
A6176
OR
TW123
FS5102 FSW5112
TFS5101
TC5102 NA
F2F5107CA1L DCS 403 NA
FS5101 FSW5111 TC5103 TC1602
NA DCS 403
HF2B5107CA1L DCS 403 NA
NA DCS 403
G1G5107CA1L DCS 403 NA NA
P3P5107CA1L NA DCS 403 FS5102 FSW5112 TC5102 NA
F2F5110CA1L DCS 603 NA
FS5101 FSW5111 TC5103 TC1602
NA DCS 403
HF2B5110CA1L DCS 603 NA
NA DCS 403
G1G5110CA1N DCS 403 NA NA
P3P5110CA1N
NA
DCS 403 FS5102 FSW5112
TC5103
NA
F3F5115CA1L DCS 603 FS5101 FSW5111 TC1602
HF3B5115CA1L DCS 403
P3P5115CA1L DCS 403 FS5102 FSW5112 NA
HF3B5120CA1L DCS 603 FS5101 FSW5111 TC1602
P3P5120CA1N DCS 403 FS5102 FSW5112 NA
F3F5125CA1L DCS 1003
T5100
A6176
OR
TW123
FS5101 FSW5111
TFS5101
TC1602
HF3B5125CA1L
P3P5125CA1N DCS 403 FS5102 FSW5112 NA
F3F5130CA1L DCS 1003 FS5101 FSW5111 TC1602
HF3B5130CA1L DCS 1003
P3P5130CA1N DCS 403 FS5102 FSW5112 NA
F3F5140CA1L NA FS5101 FSW5111 TC1602
HF3B5140CA1L DCS 403
P3P5140CA1N DCS 603 FS5102 FSW5112 NA
F3F5150CA1L NA FS5101 FSW5111 TC1602
HF3B5150CA1L
P3P5150CA1N DCS 1003 FS5102 FSW5112 NA
18
COM
001-0102
S
V
C4
C1
C2 C3
POWER
REV.1
JUNE 99
32
200
ON
90
100
TEST
1
2
60
4
3 5 6
DELAY(s)
150
RATIO(%)
ON
1
1
2
3
3
1
2
4
4MA-O%HEAT
20MA-100%HEAT
0-10VDC-CONTROL
OR C1025 WALL
THERMOSTAT
3 OR 4 STAGE
STEP CONTROL
INPUT CONTROL
12030
VR1
VR2
C
+
_
5100 Series 60 KW - 100 KW Suspended Fan Forced Unit Heater
Mounting Brackets and Accessories
Dimensions
Features & Specications
CONSTRUCTION:
Heavy gauge steel cabinet with powder coated nish and control compartment
housing a master terminal board. The control compartment allows for access
through a hinged and latched door, simplifying wiring, installation, and
maintenance.
HEATING ELEMENT:
The heating element is a copper clad steel sheath element with continuously brazed steel
ns formed to allow side draw through air ow.
OVERHEAT PROTECTION:
All units come equipped with manual reset type limit controls to de-energize the heater
should an over-temperature situation occur.
FAN & MOTOR:
Single speed, single phase permanently lubricated, thermally protected motors with ball
bearings. The fan override purges the unit of residual heat at shutdown.
FIELD INSTALLED OPTIONS:
Summer fan switch to operate the fan only, and a heat stratication thermostat for high
bay areas.
HEATER STAGING:
60 KW and 70 KW are three stage; 80 KW, 90 KW, & 100 KW are four stage.
SC5100 FACTORY INSTALLED ELECTRONIC STEP CONTROLLER:
The optional factory installed step controller is a rst on last off sequencer that will cycle
the unit heater stages through an optional wall thermostat. Additionally, the step controller
can be controlled by any building management system with 4 to 20 MA or 0 - 10 VDC eld
supplied control signal.
Optional Factory Installed Electronic Step Controller
Wall / Ceiling Bracket
Manufactured in U.S.A.
Dimensions (Inches) WT
(LBS.)
KW H W D
60-70 35 1/2 30 1/2 14 1/2 141
80-100 39 1/2 37 5/8 18 1/2 202
Mounting Brackets
UPC#
686334 Model Heater KW Description
7220002 A5175 60 To 70 Wall/Ceiling Bracket
7220102 A51100 80 to 100
7220302 B5175 60 to 70 Heater Bracket
7220402 B51100 80 to 100
7220202 V51100 60 to 100 Vertical Bracket
7220502 DS5175 60 to 70 Dust Shield
7220602 DS51100 80 to 100
7220902 OFG 5175 60 to 70 Fan Guard
7221002 OFG 51100 80 to 100
19
5100 Series 60 KW - 100 KW Suspended Fan Forced Unit Heater
Electrical Data
Air Delivery Data
Recommended Control Options
UPC#
686334 Catalog Number Step Controller Thermostat
Summer Fan Switch Stratication Thermostat
Wall Built-In Wall Built-In
721349 F3F5160CA1
SC5100 C1025 FSW5112
FS5101
TFS5101 TC5102
721356 HF3B5160CA1 FS5101
721363 P3P5160CA1 FS5102
721424 F3F5170CA1 FS5101
721431 HF3B5170CA1 FS5101
721448 P3P5170CA1 FS5102
721707 HF3B5180CA1 FS5101
721714 P3P5180CA1 FS5102
721769 HF3B5190CA1 FS5101
721776 P3P5190CA1 FS5102
721820 HF3B51100CA1 FS5101
721837 P3P51100CA1 FS5102
UPC#
686334 Catalog Number CFM at Outlet FPM at Outlet Temp Rise
°FHP Motor RPM Air Throw Max Mounting
Horizontal Vertical
721349 F3F5160CA1
3400 1485
60
1/3 1100 50’ 18’ 31’
721356 HF3B5160CA1 60/45
721363 P3P5160CA1 60
721424 F3F5170CA1 70
721431 HF3B5170CA1 70/53
721448 P3P5170CA1 70
721707 HF3B5180CA1
5000 1529
55/41
3/4 1100 65’ 22’ 40’
721714 P3P5180CA1 55
721769 HF3B5190CA1 61/46
721776 P3P5190CA1 61
721820 HF3B51100CA1 68/51
721837 P3P51100CA1 68
UPC#
686334 Catalog Number KW BTU/HR
(x 1000) Voltage Phase Control Voltage Amps / Phase Branch Circuit
Protection Size
721349 F3F5160CA1 60 204.7 208
3 24
166.7 225
721356 HF3B5160CA1 60/45 204.7/153.6 240/208 144.6/125 200/175
721363 P3P5160CA1 60 204.7 480 72.3 100
721424 F3F5170CA1 70 238.9 208
3 24
194.4 250
721431 HF3B5170CA1 70/52.5 238.9/179.2 240/208 168.7/145.8 225/200
721448 P3P5170CA1 70 238.9 480 84.3 110
721707 HF3B5180CA1 80/60 273/204.7 240/208
3 24
192.8/166.7 250/225
721714 P3P5180CA1 80 273 480 96.3 125
721769 HF3B5190CA1 90/67.5 307.1/230.4 240/208
3 24
216.9/187.5 300/250
721776 P3P5190CA1 90 307.1 480 108.4 150
721820 HF3B51100CA1 100/75 341.3/256 240/208
3 24
241/208.3 350/300
721837 P3P51100CA1 100 341.3 480 120.4 175
20
Diffuser Descriptions
Standard Heater Anemostat DiffuserRadial Louvered Cone Diffuser Linear Louvered Diffuser
For general distribution.
Choice of other diffusers
may be added after
installation if required.
O.S.H.A guard for
fan blade D1604 for
2605-2620, & D1614 for
2625-2650 Do not use
with other diffusers.
With vanes vertical, straightens air for higher
mounting. Closed position for broad horizontal
coverage. Adjustable for intermediate
requirements.
Affords more precise directional
throw where heaters cannot be
mounted directly over area to be
heated or for heating long narrow
areas.
Blends room air with
heated air for widespread
distribution without
excessive drafts.
MODEL MODEL MODELDIM: A DIM: A DIM: ADIM: B DIM: B DIM: B
MODEL
MAX
MOUNTING
HEIGHT*
MAX
MOUNTING
HEIGHT
MAX
MOUNTING
HEIGHT
MAX
MOUNTING
HEIGHT
MAX
MOUNTING
HEIGHT
VERTICAL 45 DEGREES OPEN
D
(ft.)
D
(ft.)
D
(ft.)
D
(ft.)
L
(ft.)
W
(ft.)
2605
2607
2610
2615
2620
2625
2630
2640
2650
10
10
22
20
18
32
30
26
24
25
25
40
44
48
48
60
64
68
15
15
26
24
22
38
36
32
28
25
25
36
38
40
42
50
50
50
8
8
15
14
13
24
22
20
18
30
30
44
46
50
70
74
78
82
10
10
22
20
18
34
32
30
28
10
10
14
14
15
30
34
36
40
40
40
54
60
66
80
80
90
100
9
9
20
18
16
30
28
26
24
25
25
38
40
42
60
64
67
70
*Minimum mounting height 6 feet.
**Dimensions are for all heater models without a diffuser option. Adding a diffuser will change the vertical (”A”) dimension of heater.
All mounting distances are in feet. All diagrams show optional mounting bracket.
D1600
D1610
KW
5-20
25-50
KW
5-20
25-50
KW
5-20
25-50
6 1/2"
11 1/2"
14 1/4"
24 3/4"
D1602
D1612
6"
6"
16 1/4"
22 1/4"
D1603
D1613
7"
9 3/4"
19 1/4"
29 3/4"
B
A
B
B
A
B
A
D'
L'
W'
D'
D'
B
A
B
KW
5-20
25-50
B
20 1/2”
27”
A
15”
21 1/2”
Dimensions**
2600 Series Downow Unit Heater
General Description & Diffuser Information
CONSTRUCTION:
• 16 gauge steel cabinet with epoxy powder coated nish and control compartment with a hinged and
latched access door.
• OSHA guards standard with all models.
HEATING ELEMENT:
• Corrosion resistant element with steel sheath and steel spiral ns.
OVERHEAT PROTECTION:
• All units come equipped with manual reset limit controls to de-energize the heater should an
over-temperature situation occur.
FAN and MOTOR:
• Totally enclosed, 1 speed, 1 phase permanently lubricated, thermally protected
motors with unit bearings on 3KW - 20KW models. Totally enclosed, 2 speed,
1 phase permanently lubricated, thermally protected motors with sleeve bearings
on 24KW - 50KW models.
• Axial ow fan blade - 1570 RPM max.
• All models equipped with fan purge which allows fan to operate after
elements are de-energized to purge residual heat.
TEMPERATURE CONTROLS:
• 208V, 240V, 277V and 480V units have In-Built 24 Volt transformer for low
voltage remote thermostat application.
• 600V units have In-Built 240V control on 5-20 KW models, 25-50 KW models have
24V control.
• 25 KW - 50 KW models may operate as 2 stage heaters if 2 stage remote thermostat is used.
DISCONNECT SWITCH:
• All models equipped with In-Built disconnect except F3F2640, F3F2650 and H3H2650.
INSTALLATION:
• Unit can be mounted using optional mounting bracket or eld constructed angle iron bracket.
• Not recommended for mounting with threaded rod or chain.
2600 Series shown with
standard wire guard.
Diffusers are eld installed.
Manufactured in U.S.A.
21
2600 Series Downow Unit Heater
Standard Models
Product Specications
SPECIFICATIONS: The contractor shall furnish and install the 2600 Series electric vertical discharge unit heaters of the size, capacity and
voltage specied. Heaters shall be installed according to the manufacturer’s recommendations and applicable national and local codes.
ELEMENTS: Elements shall consist of Nickel Chromium alloy resistance wire embedded and completely surrounded in Magnesium Oxide,
enclosed and swagged into corrosion resistant sheaths. Corrosion resistant steel ns shall be permanently attached to the sheaths to provide
maximum heat transfer to the air stream.
MOTORS: Motors shall be single phase, resilient mounted, totally enclosed, industrial rated with an automatic reset thermal overload protective
device. Motors on heaters up to 20 KW capacity shall be permanently lubricated shaded pole type. Over 20 KW, motors shall be permanent split
capacitor type. Motors shall be mounted out of the main air stream in such a manner as to allow ambient air to be drawn over the motor to reduce
motor temperature. Motor shall be separately removable from beneath the heater without removing the entire heater from mounting bracket.
FAN BLADES: Fan blades shall be heavy-duty individually balanced axial ow type. Fan speed shall not exceed 1570 RPM.
THERMAL OVERLOAD PROTECTION: All heaters shall be equipped with a manual reset thermal cutout which disconnects elements and
motor in the event normal operating temperatures are exceeded.
WIRING: Heaters shall be designed for a single supply circuit with elements, motor and control circuits subdivided and fused to conform with
the latest National Electric Code and OSHA requirements. All three phase heaters shall have balanced phases.
CONTROLS: Heaters shall be controlled by a low voltage wall mounted thermostat. All heaters 25 KW and larger shall be wired for 2 stage
operation. 5 KW through 20 KW units are single stage. All heaters shall be equipped with a fan safety device that causes fan to operate after
elements are de-energized to purge unit of residual heat.
UPC#
686334 MODEL KW BTU’s VOLTS PH AMPS CONTROL
VOLTS
TEMP
RISE OFCFM WT
(LBS.)
715751 F1F2605CA1
5 17065
208
1
24.03
24 34 490 75
715768 H1H2605CA1 240 20.83
715775 G1G2605CA1 277 18.05
715782 F3F2605CA1 208
3
13.89
715799 H3H2605CA1 240 12.04
715805 P3P2605CA1 480 6.02
715812 U3H2605CA4 600 4.81 240
715829 F1F2607CA1
7.5 25598
208
1
36.05
24 45 560 75
715836 H1H2607CA1 240 31.25
715843 G1G2607CA1 277 27.07
715850 F3F2607CA1 208
3
20.84
715867 H3H2607CA1 240 18.06
715874 P3P2607CA1 480 9.03
715881 U3H2607CA4 600 7.22 240
715898 F1F2610CA1
10 34130
208
1
48.07
24 26 1200 75
715904 H1H2610CA1 240 41.66
715911 G1G2610CA1 277 36.1
715928 F3F2610CA1 208
3
27.79
715935 H3H2610CA1 240 24.08
715942 P3P2610CA1 480 12.04
715959 U3H2610CA4 600 9.63 240
715966 F3F2615CA1
15 51195
208 41.68
24 39 1200 75
715973 H3H2615CA1 240 36.12
715980 P3P2615CA1 480 18.06
715997 U3H2615CA4 600 14.45 240
716000 H3H2620CA1 19.4
68260
240 48.16 24 52 1200 75716017 P3P2620CA1 20 480 24.08
717502 U3H2620CA4 600 19.26 240
717519 F3F2625CA1
25 85325
208 69.48
24
24 3300 175
717526 H3H2625CA1 240 60.21
717533 P3P2625CA1 480 30.1
717540 U3U2625CA1 600 24.08
717557 F3F2630CA1
30 102390
208 83.37
29 3300 175
717564 H3H2630CA1 240 72.25
717571 P3P2630CA1 480 36.12
717588 U3U2630CA1 600 28.9
717595 F3F2640CA1
40 136520
208 111.17
38 3300 175
717601 H3H2640CA1 240 96.33
717618 P3P2640CA1 480 48.16
717625 U3U2640CA1 600 38.53
717632 F3F2650CA1
50 170650
208 138.96
48 3300 175
717649 H3H2650CA1 240 120.42
717656 P3P2650CA1 480 60.21
717663 U3U2650CA1 600 48.16
22
2600 Series Downow Unit Heater
5700 Series Conned Space Plenum Rated Heater
A
E
C
B
DFG
• Easily ts between joists for typical installation.
• Zero clearance for wall and ceiling mounting as well as oor
mounting with appropriate inlet and outlet clearances.
• Bracket standard or can be mounted by 3/8” threaded rod
(eld supplied)
• Automatic reset thermal limit for safety
• 1 Phase model wattage eld changeable from 1874 to 5000
Watts.
• 24V control circuit on three phase models with hydraulic
thermostat
Features
Standard Models
Field Installed Accessories
A B C D E F G
14.4” 19.4” 14.5” 8.4” 5.1” 9.2” 1.8”
Product Dimensions
Conforms to ANSI/UL 1995
Certied to CAN/CSA C 22.2 No.236-11
UPC# MODEL WATTS BTU's VOLTS PHASE AMPS TEMP RISE AIR
THROW CFM WT.
(LBS.)
686334
726245 HF5705T
5000 17065
240 1
21 57 oF
16' 275 32
4165 14215 17 48 oF
3332 11365 14 38 oF
2500 8533 10 29 oF
3750 12798
208 1
18 43 oF
32
3123 10659 15 36 oF
2500 8553 12 29 oF 16' 275
1874 6396 9 21 oF
727252 H3H5705T 3750 12799 208 3 10.4 57 oF 16’ 375 32
5000 17065 240 3 12 57 oF 16' 275 32
726269 P3P5705T 5000 17065 480 3 6 57 oF 16' 275 32
707367 DCS-MT303 Optional Field Installed Disconnect Switch, 30 Amp @ 600Volts
For 24V control on single phase models delete "T" sufx
UPC#
686334 MODEL DESCRIPTION
692632 FSW5112 Summer Fan Switch
691109 TC1602 Wall Mounted Stratication Thermostat
Range - 70 oF - 140 oF
717755 A1600 Ceiling Mount Bracket 5-20 KW Models
717762 A1601 Ceiling Mount Bracket 25-50 KW Models
UPC#
686334 MODEL DESCRIPTION
717793 D1602 Linear Louvered Diffuser 5-20 KW Models
717809 D1612 Linear Louvered Diffuser 25-50 KW Models
717816 D1600 Radial Louvered Cone Diffuser 5-20 KW Models
717823 D1610 Radial Louvered Cone Diffuser 25-50 KW Models
717830 D1603 Anemostat Diffuser 5-20 KW Models
717847 D1613 Anemostat Diffuser 25-50 KW Models
23
5600 Series Multiple Wattage Fan Forced Unit Heater
Product Specications
CASING: Fabricated of die formed, heavy
gauge steel and nished with two tone,
brown and beige, durable powder coated
paint. Supply air is drawn through the
rear heavy duty expanded steel inlet grill.
Heated air is discharged through front
adjustable louvers, which are spring loaded
for individual adjustment.
ELEMENT: Heavy-duty block n
element design. The multiple tap electric
connection design allows eld conversion
to eight wattage settings at 208/240-Volt
single phase or 240/480 Volt, 3 phase.
Units are available on special order with a
specic wattage/voltage setting.
MOTOR: Motor shall be totally enclosed,
permanently lubricated, all angle industrial
rated with thermal overload protection.
WIRING: Wiring to terminal block
adjacent to incoming knockout in
accordance with NEC and local codes.
THERMAL OVERLOAD: All heaters shall be equipped with an
automatic reset thermal cutout to shut down the element and motor
circuits if unsafe operating temperatures are exceeded.
CONTROLS: The heater shall have a heavy-duty hydraulic thermostat factory installed and wired. All controls and
wiring shall be in a large wiring compartment with hinged door for easy access. An optional disconnect switch shall
be available for eld installation.
MOUNTING: Heaters are standard with a three position-mounting bracket for wall, ceiling or workbench. Heaters
can be mounted for horizontal or vertical discharge. Note: Minimum mounting height is 6 feet, and minimum distance
from side of heater to nearest wall is 6 inches. Note: Approved for residential applications.
Standard Models
Product Dimensions
Front view
Manufactured in U.S.A.
A B C D E F G
14” 12-11/16” 14” 1-9/16” 1-9/16” 9” 2-3/4”
UPC# MODEL WATTS BTU's VOLTS PHASE AMPS TEMP RISE AIR
THROW CFM WT.
(LBS.)
686334
707282 HF5605T
5000 17065
240 1
21 57 oF
16' 275 32
4165 14215 17 48 oF
3332 11365 14 38 oF
2500 8533 10 29 oF
3750 12798
208 1
18 43 oF
32
3123 10659 15 36 oF
2500 8553 12 29 oF 16' 275
1874 6396 9 21 oF
707299 H3H5605T 3750 12799 208 3 10.4 57 oF 16’ 375 32
5000 17065 240 3 12 57 oF 16' 275 32
707305 P3P5605T 5000 17065 480 3 6 57 oF 16' 275 32
707367 DCS-MT303 Optional Field Installed Disconnect Switch, 30 Amp @ 600Volts
For 24V control on single phase models delete "T" sufx
24
AA
AA
B
B
CC
D D D D D D
W W
Y Y Y Z X X XZ
Completely
Recessed
Semi
Recessed
Completely
Recessed
Semi
Recessed
A A
WWWYYY
Y
Z Z ZXXXX
BCD D D
Completely
Recessed
Semi
Recessed
Up Flow Down Flow
Ceiling Mounted
KEY: W = 6” minimum, X = 12” minimum, Y = 0” or greater, Z = 24” minimum
Product Specications
NOTE: Semi-recessed units are to be re-
cessed at a maximum of 3 1/2” unless grill
conguration is front in and front out.
MOUNTING CLEARANCES: Proper
clearances are indicated for each mount-
ing conguration on all positions. Mini-
mum clearance from side of unit to the
wall is zero inches. Mounting inches are
provided in the back of the cabinet, ac-
cessible through the blower compart-
ment, if necessary, remove blower deck
if additional mounting screws or bolts are
desired. Blower deck may be slipped for-
ward by loosening four screws at the front
to provide access to mounting holes.
Mounting Congurations
The electric cabinet unit heater is designed for mounting in any
position, fully recessed, semi-recessed or surface mounted. All
capacities, voltages, physical sizes, grille arrangements and options
shall be as specied on the plans. All units must be eld convertible
to the following:
1. For control by a eld supplied remote thermostat.
2. Load management control with an external dry switch.
When closed unit operates under control of either
the internal or the external thermostat. When open, unit
turns off.
3. Any grille arrangement.
CABINET: The cabinet shall be constructed of heavy duty 16 gauge
Zinc coated steel. The heater shall have a removable front door for
easy access to the control panel, elements, motor-blower assembly,
lters and all internal components. The grill conguration must be easily eld convertible to any air ow conguration (by
removal of no more than four fasteners). The cabinet shall have a textured nish of two coats of powder coat epoxy and be
suitable for use with optional kick space base.
HEATING ELEMENTS: The heating elements shall be warranted for 1 year and shall be non-glowing design consisting
of special high temperature resistance wire enclosed in an incoloy sheath to which steel ns are furnace brazed. The heating
elements shall be located directly in front of the blower discharge air for uniform heating. They shall be mounted with a single
anchor at one end to minimize effects of thermal expansion and contraction.
SAFETY CUTOUT: Thermal safety limits shall be built into the system to automatically shut off heater in event of overheating
due to any cause. The safety cutouts shall be of two types:
A. The primary limit shall be an automatic capillary type to sense the heat along the full length of the heating elements. It shall
de-energize the heaters by opening the coil circuit on the heating contactors.
B. The secondary limit shall be a manual reset thermal device to interrupt power to the heating elements.
MOTOR AND BLOWER ASSEMBLY: The motors and blowers shall be direct drive and resiliently mounted on rigid heavy
gauge frame for quiet operation and long life. The motor shall be two-speed, shaded pole type, rated for the voltage (480 to 600
Volts are single speed only). Each shall have built-in automatic reset overload protection and are life time lubricated. The motor
shall be vented and mounted in the air stream to provide maximum cooling of the motor.
HIGH AND LOW HEAT RANGES: All units will be supplied as standard with a switch for selecting full heat at high fan speed
or reduced heat at low fan speed (On 480 & 600 Volt units the switch changes the heat but not the fan speed).
OVER CURRENT PROTECTION: Circuit breakers shall be provided for branch circuit protection where required by NEC.
Circuit breakers are optional on all other heaters.
TEMPERATURE CONTROL: Integral factory installed thermostat shall be tamper resistant, linear capillary type.
Manufactured in U.S.A.
“T” Series Multiple Angle Cabinet Unit Heater
25
25”
11-11/16”
4-1/16”
Knockouts
12”
24”
44”
56”
1/4” Dia. Mounting Holes 3/5 KW = 33”
6/10 KW = 46”
1/2”, 3/4” Conduit
1/2”, 3/4” Conduit
1/2”, 1-1/2” Conduit
2-3/4”
2-3/8” 3-3/8”
9“
25”
1-9/16”
3“
Mounting Hole Locations
(Back View of Unit)
Product Dimensions
Product Features (2-24 KW; All Voltages)
Stocked Models & Features
• 1 / 3 phase eld convertible with 24 Volt control circuit.
• Disconnect switch, dust lter, & high low operation.
• Built-in thermostat and eld convertible for remote thermostat.
Accessories
• For commercial and institutional application such as stores,
schools, ofces, transportation terminals, churches, entrance
ways.
• Wall or ceiling mount; surface, semi-recessed or fully
recessed.
• (8) air inlet and outlet congurations.
• Capacities from 2-24 KW with 230 to 1,000 CFM
• Motors are two speed, shaded pole, resilient mounted, direct
drive. High/low heat and blower speed offer versatility.
• ETL Listed.
• Beige powder coated nish
• Choice of eight standard control options include unit or wall
mounted 120 or 24V thermostats, with or without built-in
control transformers.
• Industrial type nned tubular elements.
• Easily removable fan and element decks for simplied
maintenance.
• Full length thermal protection.
• Limited warranty-one year.
*Factory wired for 3-phase, eld convertible to 1-phase.
UPC#
686334 MODEL SIZE DESCRIPTION
DUCT COLLAR
441568 DC-33 33"
The same model is used for the inlet or outlet.
If duct collars are required for both inlet & out-
let then 2 must be ordered.
441575 DC-46 46"
441582 DC-66 66"
441599 DC-79 79"
RECESSING TRIM FRAMES
453783 TF-33 33"
Recessing Trim Frames should be ordered
to "trim-out" any recessed or semi-recessed
installation.
453790 TF-46 46"
453806 TF-66 66"
453813 TF-79 79"
UPC#
686334 MODEL SIZE
Fresh Air Make-Up Intake Flange & Kickbase
771580 FAM33 33"
771597 FAM46 46"
771603 FAM66 66"
771610 FAM79 79"
Kickbase (Pedestal) ONLY
771542 KB33 33"
771559 KB46 46"
771566 KB66 66"
771573 KB79 79"
“T” Series Multiple Angle Cabinet Unit Heater
HEATER
LENGTH
UPC#
686334 MODEL HIGH LOW VOLTS PHASE Wt.
(lbs.)
KW BTU’s AMPS CFM KW BTU’s AMPS CFM
33”
667142 T33D052033B30D0F
5 17065
25.0 / 17.6
250 3 10239
15.4 / 9.2
230
208 1-3*
99667159 T33D052433B30D0F 21.8 / 15.4 13.5 / 8.2 240 1-3*
667081 T33D054833B30D0F 7.8 4.6 480 3
46” 667197 T46D102433B30D0F 10 34130 43.6 / 30.7 500 6 20478 26.9 / 16.2 460 240 1-3* 130
667203 T46D104833B30D0F 15.4 8.1 480 3
International Models
33” 473620 6333D053834B30D0F1 5 17065 7.6 250 3 10239 4.56 230 380
3
(4-Wire)
99
473637 6333D054134B30D0F1 6.97 4.18 415
46” 473644 6346D103834B30D0F1 10 34130 15.2 500 6 20478 9.12 460 380 130
473651 6346D104134B30D0F1 13.94 8.36 415
26 Custom Specied Models
Note: Amps include motor Amp loads.
LENGTH
KW Elements per
Heat Deck CFM 1-PHASE UNITS - AMPS (HIGH) 3-PHASE UNITS - AMPS (HIGH)
208V 240V 277V 600V 208V 240V 480V
3-WIRE 600V
High Low Left Right High Low
33”
2 1 2
250 230
10.6 9.3 8.12 3.83 9.22 8.13 4.14 3.33
3 2 3 15.4 13.5 11.7 5.5 9.22 8.13 4.14 3.38
4 2 4 20.2 16.7 15.3 7.2 13.4 11.8 6 6.22
5 3 5 25 21.8 19 8 17.6 15.4 7.8 5.5
6 3 6 29.9 26 22.6 10.5 17.6 15.4 7.8 6.3
46”
4 2 2
500 460
21.1 18.6 16 7.46 18.7 16.2 8.1 6.5
6 4 3 30.8 26.9 23.1 10.79 18.4 16.2 8.1 6.5
8 4 4 40.4 35.2 30.5 14.12 26.7 23.4 11.7 9.4
10 6 5 50 43.6 37.7 17.5 35.1 30.7 15.4 12.3
12 6 6 59.6 51.9 44.9 20.8 35.1 30.7 15.4 12.3
66”
6322
750 690
31.8 27.9 24.1 11.3 27.6 24.3 12.3 9.8
9 6 3 3 46.2 40.4 35 16.3 27.6 24.3 12.3 9.9
12 6 4 4 60.6 52.9 45.8 21.3 40.1 35.2 17.7 15.6
15 9 5 5 75 65.4 56.7 25.5 52.6 46.1 23.1 15.7
18 9 6 6 89.4 77.9 67.5 31.3 52.6 46.1 23.1 18.5
79”
8422
1000 920
42.3 37.1 32 14.9 36.7 32.3 16.2 13
12 8 3 3 61.5 53.8 46.5 21.6 36.7 32.3 16.2 13
16 8 4 4 80.7 70.5 61 28.2 53.4 46.8 23.5 18.8
20 12 5 5 NA 87.1 75.4 34.9 70.1 61.4 30.7 24.6
24 12 6 6 NA NA 89.8 41.6 70.1 61.4 30.7 24.6
“T” Series Multiple Angle Cabinet Unit Heater
HOW TO DESIGNATE A MODEL:
Series Number
Cabinet Size
33=33” 46 = 46” 66 = 66” 79 = 79”
Element KW
2KW through 24KW
See model chart for length and KW options.
Element Voltage
20 = 208V 24 = 240V 27 = 277V
41 = 415V 48 = 480V 57 = 600V
Phase
1 = Single Phase 3 = Three Phase
Number of Wires in Electrical Service
2, 3, or 4
Control Options
B1, B2, B3, B4, B5, B6, B7, B8
(see control options chart)
Motor Fusing Option
M = Required O = Not Required
Disposable Filter Option
F = Required O = Not Required
Summer Fan Switch
S = Included O = Not Included
Disconnect Option
C = Circuit Breaker D = Disconnect Switch
Air Flow Configuration
A = Bottom in / Top out B = Bottom in / Front out
D = Front in / Front out
C = Front in / Top out
O = None
T 46 D 08 24 1 2 B3 S D O F
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12
27
Control Option (Step 8 on Model Designator)
Disconnect Option “C” Circuit Breaker (Step 10 on Model Designator)
Disconnect Option “D” Disconnect Switch
(Step 10 on Model Designator)
Fan Switch & Motor Fusing
(Step 11 on Model Designator)
Filter Option
(Step 12 on Model Designator)
SUFFIX DESCRIPTION
S Summer Fan Switch
MMotor Fusing
(when not provided by control option)
SUFFIX SIZE Qty.
REQ'D
FILTER
TYPE
F
33" 1
Replaceable
46" 1
66" 2
79" 2
W
33" 1
Washable
46" 1
66" 2
79" 2
KW SINGLE PHASE THREE PHASE
208V 240V 277V 600V 208V 340V 480V 600V
2
available
available
available
available
available
available
available
available
3
4
5
6
8
10
required
12
required
15
required
required
16
18
20 N/A required
24 N/A
Circuit breakers shown in shaded areas are required by NEC because unit exceeds 48 Amps, all others listed
are optional unless otherwise stated.
KW SINGLE PHASE THREE PHASE
208V 240V 277V 600V 208V 340V 480V 600V
2
available without
circuit breaker option
"C"
available without circuit
breaker option "C"
available without circuit
breaker option "C"
available without circuit breaker option "C"
available without circuit
breaker option "C"
available without circuit breaker option
"C"
available without circuit breaker option "C"
available without circuit breaker option "C"
3
4
5
6
8
10
not available
12
not available
15
not available
not available
16
18
20 not
available
24
Disconnect option is not available on heaters with circuit breaker.
SUFFIX DESCRIPTION
B3 In-Built 1-Stage Stat and Relays which are operated by an internal 24 Volt source.
B4* In-Built 1-Stage Stat and Relays which are operated by an internal 120 Volt source.
B5 In-Built 2-Stage Stat & Relays which are operated by an internal 24 Volt source.
B6* In-Built 2-Stage Stat and Relays which are operated by an internal 120 Volt source.
*Motor fusing included for units with 120V internal or external control source.
“T” Series Multiple Angle Cabinet Unit Heater
28 HOW TO DESIGNATE A MODEL:
Series Number
Cabinet Size
1=10”H x 3”D 2=14“H x 5”D 3=20”H x 5”D
Watts per Foot
Selectable in 1 watt increments up to max per model series
8510= 250 max 8520=500 max 8530=750 max
Voltage
E = 120V F = 208V G = 277V H=240V
Air Flow
B=Bottom in F=Front in
Factory Installed Options
blank=none T1 or T2=Thermostat
R1, R2, or R9=Relay DS=Disconnect
(see control option chart)
Unit Length (feet)
2, 3, 4, 5, 6, 7, 8, 9, 0 (enter 0 for 10’)
85 2 5 125 H B
DST1
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7
•Front In/Top Out or Bottom In/Top Out air
pattern.
•16 gauge steel housing powder coated with
beige nish.
•Tubular pre-wired wireway with 40 Amp
capacity.
•Connection boxes for right or left hand
wiring with combination 1/2” - 3/4”
knockouts at back and bottom.
• Stainless steel element with Aluminum ns.
•Linear limit type thermal overload with
automatic reset.
•Limited by max amp draw of 25 Amps (with
no controls).
8500 Series Commercial Slope Top Wall Convector
Standard Models
• Pencil proof louver design.
• Custom colors available, consult factory.
Note: Not for residential applications.
Note: Disconnect limits amperage to 20 Amps.
Manufactured in U.S.A.
Note: All models qualify for international use
Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges.
HEATER
LENGTH
WATTS
per
FOOT
8510 SERIES 8520 SERIES 8530 SERIES
3” Depth x 10” Height
Max watts per foot = 250
5” Depth x 14” Height
Max watts per foot = 500
5” Depth x 20” Height
Max watts per foot = 750
MODEL MODEL MODEL
2’
100-250
8512 8522 8532
333-750
3’
100-250
8513 8523 8533
333-750
4’
100-250
8514 8524 8534
333-750
5’
100-250
8515 8525 8535
333-750
6’
100-250
8516 8526 8536
333-750
7’
100-250
8517 8527 8537
333-750
8’
100-250
8518 8528 8538
333-750
9’
100-250
8519 8529 8539
333-750
10’
100-250
8510 8520 8530
333-750
29
FRONT IN
TOP OUT
BOTTOM IN
TOP OUT
Mounting/Air Flow Options
In-Built Control Options
Note: Due to size limitations, 8510 series convectors can only have thermostats as
In-Built control options.
8500 Series Commercial Slope Top Wall Convector
Product Specications
CABINET:
Rugged 16 gauge front cover with discharge louvers in sloped top design. Pencil proof louver design for
sloped outlet and front inlet grill. The nish shall be durable powder coated paint. Air ow available as
bottom in - top out, or front in - top out.
ELEMENT:
All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted
efcient dielectric to ensure proper heat transfer. Aluminum ns mechanically bonded to steel tube allows
for increased surface area and even heat transfer.
LIMIT CONTROLS:
Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater
when safe operating temperatures are exceeded.
WIRING:
Connection boxes in either end with ½ inch to ¾ inch knockouts at back and bottom. Tubular prewired wire
way with 40 Amp capacity.
CONTROLS:
Optional built in tamper resistant thermostat and disconnect is adjustable through top outlet louver.
MOUNTING:
Heater shall be surface mounted to wall or mullion. Bottom inlet units must be mounted a minimum of 4
inches above nished oor front inlet.
Voltage & Wattage Specication
Voltage Standard Wattages Per Foot Heater Lengths
120-277 100,125,150,165,187,200,250 2’ through 10’
SUFFIX DESCRIPTION
T1 In-Built Tamper Proof, Single Pole, Bimetal Thermostat - 0°-110°F temp. range,
25 Amp
T2 In-Built Tamper Proof, Double Pole, Bimetal Thermostat - 0°-110°F temp. range,
25 Amp
DS Double Pole Disconnect Switch, 20 Amp
SUFFIX DESCRIPTION
R1 DPST Relay, 30 Amps, up to 277V, 120V coil
R2 SPST Relay, 18 Amps @ 277V (max), 24V coil
R9 24V Transformer and SPST Relay, 22 Amps @240V, 18 Amps @ 277V (max), 24V coil
(cannot be used in conjunction with T2 option)
30
Standard Models
8800 Series Institutional Wall Convector
Manufactured in U.S.A.
• Single phase heaters available in all common voltages from 120V to 600V.
• 11 gauge perforated steel housing powder coated with textured ivory
nish.
• Tamper proof left side control panel houses built-in single pole thermostat
- range 40OF-110OF and disconnect switch. Thermostat on 120V-277V
units is line voltage and low voltage (24V) on 346V-600V units.
• Linear limit type thermal overload with automatic reset.
• Tamper proof fasteners
• Stainless steel element with Aluminum ns.
Note: Not for residential applications.
International Models
UPC#
686334 MODEL WATT S BTU’S VOLTS AMPS LENGTH
(IN.)
899000 E8801050
500 1706
120 4.167
18
899062 F8801050 208 2.404
899123 H8801050 240 2.083
899185 G8801050 277 1.805
899246 L8801050 346 1.445
899307 P8801050 480 1.042
899369 U8801050 600 0.833
899017 E8802075
750 2560
120 6.25
28
899079 F8802075 208 3.606
899130 H8802075 240 3.125
899192 G8802075 277 2.708
899253 L8802075 346 2.168
899314 P8802075 480 1.563
899376 U8802075 600 1.25
899024 E8803100
1000 3413
120 8.333
36
899086 F8803100 208 4.808
899147 H8803100 240 4.167
899208 G8803100 277 3.610
899260 L8803100 346 2.890
899321 P8803100 480 2.083
899383 U8803100 600 1.667
899031 E8804125
1250 4266
120 10.417
48
899093 F8804125 208 6.010
899154 H8804125 240 5.208
899215 G8804125 277 4.513
899277 L8804125 346 3.613
899338 P8804125 480 2.604
899390 U8804125 600 2.083
899048 E8805150
1500 5120
120 12.5
60
899109 F8805150 208 7.212
899161 H8805150 240 6.25
899222 G8805150 277 5.415
899284 L8805150 346 4.335
899345 P8805150 480 3.125
899406 U8805150 600 2.5
899055 E8806200
2000 6826
120 16.667
72
899116 F8806200 208 9.615
899178 H8806200 240 8.333
899239 G8806200 277 7.220
899291 L8806200 346 5.780
899352 P8806200 480 4.167
899413 U8806200 600 3.333
UPC#
686334 MODEL WATTS BTU’S VOLTS AMPS LENGTH
(IN.)
984140 M8801050i 500 1706 220 2.3 18
984157 H8801050i 240 2.1
984164 M8802075i 750 2560 220 3.4 28
984171 H8802075i 240 3.1
984188 M8803100i 1000 3413 220 4.5 36
984195 H8803100i 240 4.2
984201 M8804125i 1250 4266 220 5.7 48
984218 H8804125i 240 5.2
984225 M8805150i 1500 5120 220 6.8 60
984232 H8805150i 240 6.3
984249 M8806200i 2000 6826 220 9.1 72
984250 H8806200i 240 8.3
31
HOW TO DESIGNATE A MODEL:
Series Number
Unit Wattage
050=500 075=750 100=1000
125=1250 150=1500 200=2000
Unit Length
1=18” 2=28” 3=36”
4=48” 5=60” 6=72”
H 880 3 100
Element Voltage
E=120 F=208 G=277 H=240
L=346 P=480 U=600
5.00”
18.00”
ACCESS DOOR
4.00” Minimum
FLOOR
NOTE:
Allow 12 inch
clearance on left
end of unit and 4”
to the floor.
left side view
Optional In-Built Controls
8800 Series Institutional Wall Convector
CABINET:
Institutional enclosure 11 gauge perforated steel with sloped top design. Heavy duty end caps welded to
the enclosure. Control compartment for housing thermostat and disconnect switch is accessible by use of
security type fastener. The entire enclosure is protected by epoxy powder coated paint nish.
ELEMENT:
All steel high mass element construction with Nickel-Chromium resistance wire embedded in compacted
efcient dielectric to ensure proper heat transfer. Aluminum ns mechanically bonded to steel tube allows
for increased surface area and even heat transfer.
LIMIT CONTROLS:
Automatic reset hydraulic thermal overload covers full length of heating element and shuts down heater
when safe operating temperatures are exceeded.
WIRING:
Wiring connections shall be made in left end of cabinet enclosure. Wiring must enter into control enclosure
behind perforated steel grill.
CONTROLS:
All controls are accessible only through control enclosure door. Security type fasteners restrict access
to controls. Built in thermostat and disconnect switch with manual adjustment are located in control
enclosure.
Product Specications
*Not available on international models
SUFFIX DESCRIPTION
T2 Tamperproof, Hydraulic, Double pole In-Built thermostat range 40°-110°F, 25 Amp
24V* 24 Volt In-Built single pole thermostat for 120V 208V, 240V & 277V models.
32
HOW TO DESIGNATE A MODEL:
Unit Length (Inches)
24, 36, 48, 60, or 72
Total Wattage
Series Number
Cabinet Size
25=11”H x 4”D 45=20”H x 5”D
Voltage/Phase
F=208V, 1 Phase G=277V, 1 Phase
H=240V, 1 Phase J=208V, 3 Phase
K=240V, 3 Phase
Control Option
Blank=None
T or T2=Thermostat R, R2, or R9=Relay
(See control option chart)
M41
25 F 48
1000
T
4100 Series Recessed Commercial Wall Convector
M4125 Dimensions - Cabinet Sizes 4” Deep x 11” High
M4145 Dimensions - Cabinet Sizes 5” Deep x 20” High
• Front In / Front Out air pattern
•16 gauge steel housing powder coated with
textured beige nish.
•Tubular pre-wired wireway with 40 Amp
capacity.
•Connection boxes for right or left hand wiring
with combination 1/2”-3/4” knockouts at
back and bottom.
• Steel heating element with steel ns.
•Linear limit thermal overload with automatic
reset.
• Recess trim frame included.
• Custom colors available, consult factory.
Note: Not for residential applications.
Manufactured in U.S.A.
Note: Products listed in this section are custom built and subject to 100% cancellation/restocking charges.
LENGTH (Inches) WEIGHT (Lbs.) WATTS per FOOT
AVAILABLE VOLTS AVAILABLE PH
24 20
187
250
333
208
240
277
1
36 33
48 39
60 49
72 56
LENGTH
(Inches)
WEIGHT
(Lbs.)
WATTS per FOOT
AVAILABLE
VOLTS
AVAILABLE PH LENGTH
(Inches)
WEIGHT
(Lbs.)
WATTS per FOOT
AVAILABLE
VOLTS
AVAILABLE PH
24 45
187
250
333
208
240
277
24 49
750
208
240
277
36 53 36 60
48 63 1 48 71 1
60 77 60 87
72 92 72 106
24 47
500
666
208
240
277
24 49
500
666
750
208
240
36 57 36 60
48 67 1 48 71 3
60 82 60 87
72 100 72 106
33
4100 Series Recessed Commercial Wall Convector
In-Built Control Options for Single Phase Units
Note: No In-Built control options for 3 phase models.
12” Control Section
Note: Control section required when relay is ordered.
Solid Back Panel
CABINET:
4100 series casing shall be of square design with front inlet and outlet grills suitable for
recess installation. The cabinet is fabricated from 16 gauge cold rolled steel and nished
with powder coated baked enamel. Junction boxes are available for left or right wiring and
connected by pre-wired 40 Amp capacity wireway.
ELEMENT:
All steel high mass element construction with Nickel-Chromium resistance wire embedded
in compacted efcient dielectric to ensure proper heat transfer. Aluminum ns mechanically
bonded to steel tube allows for increased surface area and even heat transfer.
LIMIT CONTROLS:
Automatic reset hydraulic thermal overload covers full length of heating element and shuts
down heater when safe operating temperatures are exceeded.
WIRING:
Wiring connections shall be made in left end of cabinet enclosure. Wiring must enter into
control enclosure behind perforated steel grill.
CONTROLS:
All controls are accessible only through control enclosure door. Security type fasteners
restrict access to controls. Built in thermostat with manual adjustment are located in control
enclosure.
UNIT LENGTH MODEL 4125 MODEL 4145
12” MSE4120-12 MSE4140-12
UNIT LENGTH MODEL 4125 MODEL 4145
24” MS4122 MS4142
36” MS4123 MS4143
48” MS4124 MS4144
60” MS4125 MS4145
72” MS4126 MS4146
SUFFIX DESCRIPTION
T In-Built Tamper Proof, Single Pole, Hydraulic Thermostat - 40°-110°F temp. range, 25 Amps
T2 In-Built Tamper Proof, Double Pole, Hydraulic Thermostat - 40°-110°F temp. range, 25 Amps
R DPST Relay, 30 Amps, up to 277V, 120V coil
R2 SPST Relay, 18 Amps @ 277V (max), 24V coil
R9 24V Transformer and SPST Relay, 22 Amps @24V, 18 Amps @ 277V (max), 24V coil
34
Selectable Wattages, Back Cans, And Power Disconnects
Recess, Surface, Or
“T” Bar Mounting
Standard Models
Field Installed Accessories
The heaters are be constructed of a heavy gauge steel housing. The rough-
in dimensions are 19-3/16” wide x 4” deep. The nish shall be baked-on
powder coat in Ceiling White color. The units shall be available in ratings
from 1500 through 4800 Watts with an optional factory installed single pole
thermostat.
The heaters have a low speed 600-RPM motor, which drives a vane axial
blower to deliver a quite 175 CFM’s of down ow air. The heating element
shall be of the block nned type with large, parallel steel ns for quick heat
transfer. Unit shall have as standard, a manual reset capillary type limit
control, for added safety. Unit weight 22 pounds.
Product Specications
Features & Standard Models
Accessories
3000 Series Fan Forced Ceiling Heater
3380 Series Commercial Fan Forced Ceiling Heater
• Wattage selectable at time of installation - models shipped wired to highest Wattage
•
Fan purge circuit (has 2 wire control circuit for use with remote wall thermostat)
• Models may not be used with remote double pole thermostat
• Drywall depth embossments on back can
• Powder coated 18 gauge steel front
• Manual reset thermal limit
• Steel block n element
• Propeller style fan blade - 1060 RPM / 100 CFM
• Weight 6 lbs.
• Optional eld installed control voltage relays available
• Rough in dimensions - 9 1/4” Wide - 12 1/8” High - 3 5/8” Deep
• Grill dimensions: 9 25/32” Wide - 13” High
•
Fan purge circuit (has 2 wire control circuit for use
with remote wall thermostat)
• Disconnect switch
• White powder coated 18 gauge steel grill
• Manual reset thermal limit
• Steel block n element
• Vane axial fan blade:
1.5KW - 4.0KW units: 700 RPM motor; 175
CFM 4.8KW units: 900 RPM motor; 200 CFM
• Rough in dimensions:
14 3/16” wide x 19 5/16” high x 4” deep
• Grill dimensions:
15 3/8” wide x 20 9/64” high
• Optional factory installed tamper resistant
thermostat
Manufactured in U.S.A.
Manufactured in U.S.A.
WHITE SELECTABLE
INSTALLATION WATTAGE
MAX
BTU'S VOLTS MAX
AMPS
UPC#
686334 MODEL
948821 E3035DWBW 750 or 1500 5120 120 13
948838 E3038DWBW 900 or 1800 6143 120 15
948883 H3032DWBW 750 or 1000 - 1500 or 2000 6826 208 / 240 8
948906 G3032DWBW 2000 6826 277 7
UPC
686334 MODEL DESCRIPTION
996846 30R 24 VOLT RELAY
996853 30R2 120 VOLT RELAY
951500 30R8 208/240 VOLT RELAY
951494 30R7 277 VOLT RELAY
996976 303EX8RW 1" EXTENDER
996969 303EX16RW 2" EXTENDER
996952 303EX32RW 4" SURFACE MOUNT FRAME
460033 TB3000 T-BAR FRAME
UPC
686334 MODEL DESCRIPTION WT.
377850 BOX3310 Additional Back Can 10 lbs
381109 3380EX33 Surface Mounting Adapter 1 lb
460026 TB3380 2X2 T-Bar Mounting Kit 7 lbs
Thermostat- Add sufx T to model Factory installed single pole, positive off. Range-60° F-105° F
UPC#
686334 MODEL KW BTU’S VOLTS PH AMPS TEMP
RISE
366489 E3383D-RP 1.5 5120 120
1
12.5 27 °F
366298 F3386D-RP 4.0 13600 208 19.2 72 °F
366304 F3387D-RP 4.8 16382 208 23.1 76 °F
366342 HF3384D-RP 2.0 / 1.5 6826/5120 240/208 8.3/7.2 36 °F
366359 HF3385D-RP 3.0 / 2.3 10200/7679 240/208 12.5/10.8 54 °F
366366 HF3386D-RP 4.0 / 3.0 13600/10200 240/208 16.8/14.4 72 °F
366373 H3387D-RP 4.8 16382 240 20 76 °F
366502 G3383D-RP 1.5 5120 277 5.4 27 °F
366410 G3384D-RP 2.0 6826 277 7.2 36 °F
366427 G3385D-RP 3.0 10200 277 10.8 54 °F
366434 G3386D-RP 4.0 13600 277 14.4 72 °F
366441 G3387D-RP 4.8 16382 277 17.3 76 °F
International Models
470889 M3384D-RPi 1680 5734
220 1
7.6 30 °F
470896 M3385D-RPi 2520 8600 11.5 50 °F
470902 M3386D-RPi 4032 13761 18.3 72 °F
35
Optional controls must be factory installed. Field installation is not
acceptable and violates Listing and factory warranty.
Wall mounted control panels may control multiple units but cannot
be used if in-built controls are selected.
480V units include 24V transformer and relay as standard (A1) -
only TS option control section can be added. Depth dimension of all
480V models is 10-7/8”
Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw
designed for 8 to 12 foot ceilings. db RE 10-12 Watt=63.9
Unit Weight: 50 lbs.
Recommended Remote Thermostats:
Line Voltage: Single Phase 208-240V ET5DS
Single Phase 277V ET5SS
Three Phase TW1512
Low Voltage: UT1001
• White powder coated 20 gauge grill.
• 208V, 240V, & 277V units have manual reset thermal limit.
• 480V units have manual reset thermal limit, 24V control transformer,
and 24V relay (A1 sufx).
• Enclosed steel n sheath element.
• Rough in dimensions: 23-1/16” sq. x 9-1/8” deep.
Notes
Standard Models
Product Dimensions
Product Specications
Features
Factory Installed Control Sections
Contractor shall supply and install heavy duty ceiling mounted
forced air electric heater(s) of the wattage, voltage and phase as
indicated on the plans. The heater shall be so designed to provide an
even distribution of heated air to the space to be heated by drawing
return air in the periphery of the heater, across and through the
element and be discharged from the center section of the heater by
means of an electric motor and axial ow fan blade.
Heaters shall be recessed type and mounted ush with the nished
ceiling. The return grille assembly shall be constructed of a one
piece heavy gauge steel with 1/4” slots for return air and concentric
rings for uniform air discharge. Grille assembly shall be attached to
chassis by tamper-resistant (allen head) machine screws. All parts
of enclosure shall be heavy gauge steel, zinc coated both sides and
nished in neutral off white powder coat paint.
Enclosure shall be constructed of 1/6” x 3/8” rounded edge
horizontal steel louvers which shall be spaced for maximum opening
of 5/16”. Louvers shall be welded at every intersection to evenly
spaced 1/8” diameter vertical members. Discharge grille to have
concentric rings for uniform air discharge. Grille assembly shall be
attached to chassis by tamper-resistant (allen head) machine screws.
All part of enclosure shall be heavy gauge steel, Zinc coated both
sides and nished in neutral off white colored powder coat nish.
Motor shall be permanent lubricated, unit bearing, totally
enclosed, impedance protection. Motors shall operate at no more
than 1300 RPM and shall be same voltage as the heater.
Heaters shall have a rating of 425 CFM at 710 F.P.M. with a
maximum temperature rise of 44°F and 63.9 DB RE 1012 Watt.
Element assemblies shall consist of two or three corrosion
resistant steel sheathed type elements mechanically bonded to
common corrosion resistant steel ns. Each sheathed element shall
consist of helically coiled Nickel Chromium alloy resistant wire
completely embedded in and surrounded by magnesium oxide,
enclosed and wedged into corrosion resistant steel sheaths. Elements
shall have 2” cold conductor pins extending into sheath and shall
have a density of no more than 60 Watts per inch.
Heaters shall be equipped with a “manual reset” thermal overload
which disconnects elements and motor in the event normal operating
temperatures are exceeded. For safety, if opened due to abnormal
temperature, thermal overload shall remain open until manually
reset. Automatic reset thermal overloads which allow the element
to continue to cycle under abnormal conditions will not be accepted.
Heaters shall be ETL listed.
Manufactured in U.S.A.
SUFFIX DESCRIPTION
A1 Transformer with 24V Secondary and 24V Relay
S Disconnect Switch
TA1S Thermostat / Transformer / Disconnect Switch
TA1 Single Pole Thermostat and Transformer with 24V Secondary and 24V Relay
A1S Transformer with 24V Secondary and 24V Relay and Disconnect Switch
T2 Double Pole Thermostat
T2S Double Pole Thermostat and Disconnect Switch
RRelay Control Voltage Same as Heater (control voltage eld supplied)
R1 Relay 24V Control Voltage (control voltage eld supplied)
R2 Relay 120V Control Voltage (control voltage eld supplied)
T Single Pole (480V only)
L Factory installed adjustable louver diffuser option.
RCH Series Commercial Fan Forced Recessed Mounted Ceiling Heater
UPC#
686344 MODEL KW BTU’S VOLTS PH AMPS TEMP
RISE
367653 81RCH2
2 6826
208
1
9.6
15 °F
367677 21RCH2 240 8.3
367660 71RCH2 277 7.2
318471 41RCH2A1 480 4.2
470186 83RCH2
2 6826
208
3
5.6
15 °F470209 23RCH2 240 4.8
470247 43RCH2A1 480 2.4
367684 81RCH3
3
10200
208
1
14.4
22 °F
367707 21RCH3 240 12.5
367691 71RCH3 277 10.8
318488 41RCH3A1 480 6.3
470193 83RCH3
3
208
3
8.3
470216 23RCH3 240 7.2
470254 43RCHA1 480 3.6
367714 81RCH4
4
13600
208
1
19.2
30 °F
367738 21RCH4 240 16.8
367721 71RCH4 277 14.4
318501 41RCH4A1 480 8.3
367745 83RCH4
4
208
3
11.1
367752 23RCH4 240 9.7
318587 43RCH4A1 480 4.8
367769 81RCH5
5
17000
208
1
24.1
37 °F
367783 21RCH5 240 20.8
367776 71RCH5 277 18.1
318549 41RCH5A1 480 10.4
367790 83RCH5
5
208
3
13.9
367806 23RCH5 240 12.1
318402 43RCH5A1 480 6.1
366106 PT3480 Recess Frame - Weight 5 lbs.
International Models
470971 M3482T2i 2 6826 220
1
9.1 15 °F
470988 N3482T2i 240 8.3
470995 M3483T2i 3 10200 220 13.6 22 °F
471008 N3483T2i 240 12.5
471015 M3484T2i 4 13600 220 18.2 30 °F
471022 N3484T2i 240 16.7
36 Contractor shall supply and install heavy duty ceiling mounted forced air
electric heater(s) of the wattage, voltage and phase as indicated on the plans. The
heater shall so be designed to provide an even distribution of heated air to the space to
be heated by drawing return air in the periphery of the heater, across and through the
element and be discharged from the center section of the heater by mean of an electric
motor and axial ow fan blade.
Motor: Motor shall be permanent lubricated, unit bearing, totally enclosed
shaded pole type with impedance protection. Motors shall operate at no more than
1300 RPM and shall be same voltage as the heater.
Performance: Heaters shall have a rating of 425 CFM at 710 F.P.M. with a
maximum temperature rise of 44°F and 63.9 DB RE 1012 Watt.
Element: Element assemblies shall consist of two or three corrosion resistant
steel sheathed type elements mechanically bonded to common corrosion resistant
steel ns. Each sheathed element shall consist of helically coiled Nickel Chromium
alloy resistant wire completely embedded in and surrounded by Magnesium Oxide,
enclosed and wedged into corrosion resistant steel sheaths. Elements shall have 2”
cold conductor pins extending into sheath and shall have a density of no more than 60
watts per inch.
Thermal Overload: Heaters shall be equipped with a “manual reset” thermal
overload which disconnects elements and motor in the event normal operating
temperatures are exceeded. For safety, if opened due to abnormal temperature,
thermal overload shall remain open until manually reset. Automatic reset thermal
overloads which allow the element to continue to cycle under abnormal conditions
will not be accepted.
Approval: Heaters shall be ETL listed.
Commercial and Institutional Applications: Use in - vestibules, entrance
ways, lobbies, rest rooms and small ofce and guard building applications.
Product Dimensions
Product Specications
Wall Mounted Control Panels
Standard Models
Factory Installed Control Sections
Notes
Optional controls must be factory installed. Field installation is
not acceptable and violates Listing and factory warranty.
Factory installed control sections add 2-5/16” to the height of
the unit.
Wall mounted control panels may control multiple units but
cannot be used if In-Built controls are selected.
480V units include 24V transformer and relay as standard (A1)
- only TS option control section can be added. Depth dimension
of all 480V models is 10-7/8”
Degree F air rise is measured at 710 F.P.M. and 425 CFM. Throw
designed for 8 to 12 foot ceilings. db RE 10-12 Watt=63.9
Unit weight: 32 lbs.
Recommended Remote Thermostats:
Line Voltage: Single Phase 208-240V ET5DS
Single Phase 277V ET5SS
Three Phase TW1512
Low Voltage: UT1001
Manufactured in U.S.A.
UPC#
686334 MODEL VOLTS CONTACTORS BOX
SIZE
605700 AF3401-24 208
1 @ 35 AMPS 1 2 " x 1 2 "
x 4 1/2"
605793 AH3401-24 240
605854 AG3401-24 277
605748 AF3402-24 208
2 @ 35 AMPS 1 5 " x 1 5 "
x 4 1/2"
605786 AH3402-24 240
605847 AG3402-24 277
605731 AF3403-24 208
3 @ 35 AMPS 1 8 " x 1 8 "
x 4 1/2"
605779 AH3403-24 240
605830 AG3403-24 277
SUFFIX UNITS DESCRIPTION
TS 1-Phase Single Pole Thermostat - range 40°-110°F and Disconnect
Switch
TA1S 3-Phase Single Pole Thermostat - range 40°-110°F & Transformer with
24V Secondary and 24V Relay & Disconnect Switch
A1S 1 or 3
Phase
Transformer with 24V Secondary and 24V Relay and
Disconnect Switch
T Single Pole (480V only)
SCH Series Commercial Fan Forced Surface Mounted Ceiling Heater
UPC#
686334 MODEL KW BTU’S VOLTS PH AMPS TEMP
RISE
367516 81SCH2
2 6826
208
1
9.6
15 °F
367530 21SCH2 240 8.3
367523 71SCH2 277 7.2
324335 41SCH2 480 4.2
470155 83SCH2
2 6826
208
3
5.6
470162 23SCH2 240 4.8
470223 43SCHA1 480 2.4
367547 81SCH3
3 10200
208
1
14.4
22 °F
367561 21SCH3 240 12.5
367554 71SCH3 277 10.8
324342 41SCH3 480 6.3
323864 83SCH3
3 10200
208
3
8.3
470179 23SCH3 240 7.2
470230 43SCHA1 480 3.6
367578 81SCH4
4 13600
208
1
19.2
30 °F
367592 21SCH4 240 16.8
367585 71SCH4 277 14.4
324359 41SCH4 480 8.3
367608 83SCH4 208
3
11.1
367837 23SCH4 240 9.7
324366 43SCH4 480 4.8
367615 81SCH5
5 17000
208
1
24.1
37 °F
367639 21SCH5 240 20.8
367622 71SCH5 277 18.1
324373 41SCH5 480 10.4
367646 83SCH5 208
3
13.9
367844 23SCH5 240 12.1
324380 43SCH5 480 6.1
International Models
470919 M3472T2i 2 6826 220
1
9.1 15 °F
470926 N3472T2i 240 8.3
470933 M3473T2i 3 10200 220 13.6 22 °F
470940 N3473T2i 240 12.5
470957 M3474T2i 4 13600 220 18.2 30 °F
470964 N3474T2i 240 16.7
37
CP & RCP Series Radiant Ceiling Panel Heaters
For Surface Or Recessed Installation, Radiant
Ceiling Panels radiate energy like the solar
radiation which warms us, heats objects, not
the air. With no moving parts, these heating panels create gentle
warmth and toasty comfort.
Radiant Ceiling Panels provide a low surface temperature and
broad heat distribution. Clean, gentle comfortable heat that is
ideal for offsetting perimeter heat loss or neutralizing downdrafts
over glass. These versatile and exible panels may be used
virtually anywhere in homes, schools, hospitals, motels and a
broad variety of other commercial or industrial installations.
Product Specications
Product Description
CP Series - “T” Bar & Surface Mounted RCP Series - Frame in Ceiling Mounted
Construction:
Radiant Ceiling Panels shall be made of highest quality steel casing.
Front panel shall be painted with textured powder coated nish.
Electric Resistance element is xed between dielectric material and
insulation. Two inches of insulation is compressed to one inch by back
panel to minimize upward heat loss and radiant efciency. Radiant
panels shall have 36” pre-wired exible cable for easy installation and
wiring connections.
Installation:
CP Series shall be designated as 2x2 or 2x4 size. All panels are 1”
thick. The size shall be nominal dimension to be manufactured to t
drop ceiling systems. Standard units will t regular “T” Bar frame.
For regular or trim line or other frame sizes, special construction is
required. RCP Series shall be used in recess mounting applications.
RCP Series shall be 2” less in width to recess between nominal 24”
center ceiling joists. RCP Series shall be complete with recess frame
for nished construction.
Accessories:
Surface mounting frames shall be optional for surface mounting the CP
Series, and are Aluminum mill nish. Frames can be painted white to
match panel.
Options:
Silk-screening the exposed surface to match ceiling tiles is available,
as well as silicone sealed metal parts for high humidity applications.
Manufactured in U.S.A.
International Models
UPC#
686334 MODEL WATTS BTU's AMPS VOLTS WT
Dimensions: 2' x 4' (Nominal) x 1"
458719 CP805
500 1707
2 208
20 lb.458726 CP125 4.2/2.1 120/240
458733 CP705 2 277
458740 CP807
750 2560
4 208
20 lb.458757 CP127 6.3/3.1 120/240
458764 CP707 3 277
Dimensions: 2' x 2' (Nominal) x 1"
458771 CP802
250 853
1 208
13 lb.458788 CP122 2.1/1.0 120/240
458795 CP702 .9 277
458801 CP803
375 1280
2 208
13 lb.458818 CP123 3.1/1.6 120/240
458825 CP703 1 277
459105 SF400 Surface Frame for 2’ x 4’ Panels (CP only) 10 lb.
459099 SF200 Surface Frame for 2’ x 2’ Panels 6 lb.
UPC# MODEL WATTS BTU's AMPS VOLTS WT
686334
Dimensions: 2' x 4' (Including Recessing Frame)
458832 RCP805
500 1707
2 208
30 lb.458849 RCP125 4.2/2.1 120/240
458856 RCP705 2 277
458863 RCP807
750 2560
4 208
30 lb.458870 RCP127 6.3/3.1 120/240
458887 RCP707 3 277
Dimensions: 2' x 2' (Including Recessing Frame)
458894 RCP802
250 853
1 208
19 lb.458900 RCP122 2.1/1.0 120/240
458917 RCP702 .9 277
458924 RCP803
375 1280
2 208
19 lb.458931 RCP123 3.1/1.6 120/240
458948 RCP703 1 277
UPC#
686334 MODEL WATTS BTU's AMPS VOLTS WT
Dimensions: 2' x 4' (Nominal) x 1"
471039 CP2205i 420 1434 1.9 220 20
471046 CP125i 500 1707 4.2/4.1 120/240
471053 CP2207i 630 2150 2.9 220 20
471060 CP127i 750 2560 6.3/3.1 120/240
Dimensions: 2' x 2' (Nominal) x 1"
471077 CP2202i 210 717 0.95
13
471084 CP122i 250 853 2.1/1.0 120/240
0.9 277
471091 CP2203i 315 1075 1.4 220
13
471107 CP123i 375 1280 3.1/1.6 120/240
1.4 277
UPC#
686334 MODEL WATTS BTU's AMPS VOLTS WT
Dimensions: 2' x 4' (Including Recessing Frame)
471114 RCP2205i 420 1434 1.9 220
30
471121 RCP125i 500 1707 4.2/4.1 120/240
471138 RCP2207i 630 2150 2.9 220
471145 RCP127i 750 2560 6.3/3.1 120/240
Dimensions: 2' x 2' (Including Recessing Frame)
471152 RCP2202i 210 717 0.95 220
19
471169 RCP122i 250 853 2.1/1.0 120/240
471176 RCP2203i 315 1075 1.4 220
471183 RCP123i 375 1280 3.1/1.6 120/240
38
CVX Series Radiant Cove Ceiling Heater
Cove Heaters have a subtly contoured concave surface with a saw-tooth prole. The concave parabolic face plate
performs a two-fold function: (1) it focuses the infrared rays and (2) directs the heat downward along cold perimeters
and toward the center of the room. The sawtooth surface design increases the radiating surface area by 45%, thereby
increasing the comfort level of the room faster and insuring more rapid recovery from heat losses.
Furnish and install Electric Cove Heaters where specied. The heaters shall be constructed of .962” thick Aluminum.
The heater surface shall be concave in contour and saw-tooth in prole. The nish shall be of powder coat white nish.
The heaters shall be available in ratings from 450 through 1250 Watts, at 120, 240, 208 and 277 Volts. The heating
element shall be of Nichrome wire, embedded in Magnesium Oxide powder, enclosed and sealed in Aluminum metal
tubing. The heater shall be listed by ETL and the elements shall be supplied with a one year limited warranty.
Product Specications
Product Description
Accessories & Dimensions
* Order 2 for units up to 72”
Order 3 for units over 72”
Standard Models
Manufactured in U.S.A.
UPC#
686334 MODEL DESCRIPTION W T.
457927 CVCBX Ceiling Bracket* 1/2 lb.
457866 CVB42X 42” Blank Section 6 lb.
457873 CVB60X 60” Blank Section 8 lb.
457880 CVB84X 84” Blank Section 12 lb.
457912 CVSP Aerosol Touch-up Paint 1 lb.
UPC#
686334 MODEL WATTS BTU's AMPS VOLTS LENGTH WT.
457583 CV4512X 450
1536
4 120
42” 7 lb.
457590 CV45X 450 2 240
457606 CV45YX 450 2.0 208
457613 CV4527X 450 2 277
457620 CV6012X 600
2048
5.0 120
60” 10 lb.
457637 CV60X 600 3 240
457644 CV60YX 600 3 208
457651 CV6027X 600 2 277
457668 CV7512X 750
2560
6 120
72” 13 lb.
457675 CV75X 750 3 240
457682 CV75YX 750 3.6 208
457699 CV7527X 750 3 277
457705 CV9012X 900
3072
8 120
84” 14 lb.
457712 CV90X 900 4 240
457729 CV90YX 900 4 208
457736 CV9027X 900 3 277
457743 CV10012X 1000
3413
8 120
96” 17 lb.
457750 CV100X 1000 4 240
457767 CV100YX 1000 5 208
457774 CV10027X 1000 4 277
457781 CV11012X 1100
3754
9 120
108” 19 lb.
457798 CV110X 1100 5 240
457804 CV110YX 1100 5 208
457811 CV11027X 1100 4.0 277
457828 CV12512X 1250
4266
10 120
120” 21 lb.
457835 CV125X 1250 5 240
457842 CV125YX 1250 6.0 208
457859 CV12527X 1250 5 277
International Models
471190 CV4522Xi 450 1536 2.0 220 42” 7
471206 CV45Xi 1.9 240
471213 CV6022Xi 600 2048 2.7 220 60” 10
471220 CV60Xi 2.5 240
471237 CV7522Xi 750 2560 3.4 220 72” 13
471244 CV75Xi 3.1 240
471251 CV9022Xi 900 3072 4.1 220 84” 14
471268 CV90Xi 3.8 240
471275 CV10022Xi 1000 3413 4.5 220 96” 17
471282 CV100Xi 4.2 240
471299 CV11022Xi 1100 3754 5.0 220 108” 19
471305 CV110Xi 4.6 240
471312 CV12522Xi 1250 4266 5.7 220 120” 21
471329 CV125Xi 5.2 240
39
3000 Series Midsized Commercial Fan Forced Wall Heater - Multiple Wattage
Approved for
wall or ceiling
installation
• Wattage selectable at time of installation.
• Models shipped wired to highest wattage.
• Approved for horizontal mounting - right or left discharge.
• Fan purge circuit.
• Disconnect switch.
• Drywall depth embossments on back can.
• 18 gauge powder coated steel & extruded Aluminum front.
• Manual reset thermal limit.
• Steel block n element.
• Propeller style fan blade: 1060 RPM motor; 100 CFM.
• Weight 6 lbs.
• Rough in dimensions: 9 1/4” Wide x 12 1/8” High x 3 5/8” Deep.
• Grill dimensions: 10” Wide x 13 1/8” High.
Features
Standard Models
Accessories
Manufactured in U.S.A.
UPC#
686334 MODEL SELECTABLE INSTALLATION WATTAGE MAX VOLTS MAX
BTU’s AMPS
TAMPERPROOF IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90º TEMPERATURE RANGE)
996211 E3055T2DWB 750 or 1500 5120 120 12.5
996228 E3058T2DWB 900 or 1800 6143 120 15.0
996259 F3052T2DWB 1000 or 2000 6826 208 8.3
945691 F30522T2DWB
500 or 750 or 1000 or 1250
7680 208 10.8
or 1500 or 1750 or 2250
996280 H3052T2DWB 750 or 1000 - 1500 or 2000 6826 208 / 240 8.3
945721 H30522T2DWB
500 or 750 or 1000 or 1250
7680 240 9.4
or 1500 or 1750 or 2250
996310 G3052T2DWB 2000 6826 277 7.2
TAMPERPROOF IN-BUILT SINGLE POLE THERMOSTAT (50º - 90º TEMPERATURE RANGE)
996068 E3055TDWB 750 or 1500 5120 120 12.5
996075 E3058TDWB 900 or 1800 6143 120 15.0
996105 F3052TDWB 1000 or 2000 6826 208 8.3
945639 F30522TDWB
500 or 750 or 1000 or 1250
7680 208 10.8
or 1500 or 1750 or 2250
996136 H3052TDWB 750 or 1000 - 1500 or 2000 6826 208 / 240 8.3
945660 H30522TDWB
500 or 750 or 1000 or 1250
7680 240 9.4
or 1500 or 1750 or 2250
996167 G3052TDWB 2000 6826 277 7.2
UPC#
686334 MODEL DESCRIPTION
996945 305EX8 1” EXTENDER
996938 305EX16 2” EXTENDER
996921 305EX32 4” SURFACE MOUNT FRAME
40 Features
Accessories
Product Specications
Standard Models
4400 Series Low Prole Commercial Fan Forced Wall Heater - With Wall Box
Accessories
Standard Models
Manufactured in U.S.A.
Manufactured in U.S.A.
Furnish and install Heavy-Duty Forced Air wall heaters, where specied. The heaters
shall be constructed of a heavy 18 gauge steel housing with an extruded Aluminum
frame. The rough-in dimensions are 19-7/16” High x 14-3/16” Wide x 4” Deep. The
units shall be available in ratings from 750 to 4800 Watts at 240, 208, and 277 Volts.
The heaters shall have a low-speed 600 RPM, 4-pole motor which drives a vane axial
blower to deliver a quiet 175 CFM of down ow air. The heating element shall be
of the sealed tubular type with large, parallel steel ns
for quick heat transfer. Unit shall have as a standard,
a thermal overload cut-off for added safety, fan delay
switch and built-in tamper proof thermostat which shall
be calibrated to provide a range of 55°F. to 85°F. and
manual disconnect switch.
Optional accessories shall include a surface and semi-
recess mounting adapter. All heaters shall be listed by
ETL. The heating element shall be supplied with a
manufactures 1-year limited warranty.
• Disconnect switch. • Built-In tamper proof thermostat.
• Automatic fan delay circuit.
• Powder coated 18 gauge steel grill with extruded Aluminum front frame.
• Automatic reset thermal limit.
• Steel block n element.
• Vane axial fan blade:
600 RPM motor; 175 CFM
• Rough-in dimensions:
14-3/16” Wide x 19-7/16” High x 4” Deep
• Grill dimensions:
15-29/32” Wide x 20-27/32” High
• Powder coated 20
gauge steel front
with extruded
Aluminum frame.
• Manual reset
thermal limit.
• Finned tubular
steel element.
• Propeller style fan blade - 2200 RPM/70 CFM
• Weight 9 lbs.
• Rough in dimensions:
14 1/2” Wide x 7 1/8” High x 3 1/2” Deep
• Grill dimensions:16 7/8” Wide x 8” High
• Unit not approved for ceiling mount applications.
• Unit can be positioned to allow left, right or top
discharge.
UPC MODEL VOLTS WATTS MAX AMPS
686334 BTU’S
DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50º - 90º F)
328326 F4420T2RP 208 2000 6826 9.6
328333 HF4475T2RP
240/208
750 / 562 2560 / 1920 3.1 / 2.7
328340 HF4410T2RP 1000 / 750 3413 / 2560 4.2 / 3.6
328357 HF4415T2RP 1500 / 1125 5120 / 3840 6.3 / 5.4
328364 HF4420T2RP 2000 / 1500 6826 / 5120 8.3 / 7.2
SINGLE POLE IN-BUILT THERMOSTAT (RANGE 50º - 90º F)
328371 E4475TRP
120
750 2560 6.25
328388 E4410TRP 1000 3413 8.33
328395 E4415TRP 1500 5120 12.5
328401 F4420TRP 208 2000 6826 9.6
UPC MODEL DESCRIPTION WT.
686334 LBS.
329910 4400EX8 1” SEMI RECESSING EXTENDER 2
329903 4400EX16 2” SEMI RECESSING EXTENDER 3
329897 4400EX32 4” SURFACE MOUNTING FRAME 4
328449 4300PB WALL PLATE ADAPTOR (OD 21.5”x12.25”) 1
UPC#
686334 MODEL DESCRIPTION TYPE WT.
lbs.
328746 BOX AFA Additional Rough-in Box
Field
Installed
3
328753 AFAEX33 4” Surface Mounting Frame 1
328760 AFAEX16 2” semi recess extender 1
----- Sufx - HD 16 Gauge Steel
Heavy Duty Grill
Factory
Installed 2
AFA Series Commercial Fan Forced Wall Heater
UPC#
686334 MODEL WATT S BTU’s VOLTS AMPS WT.
LBS.
IN-BUILT SINGLE POLE TAMPERPROOF THERMOSTAT (50º - 90º TEMPERATURE RANGE)
FOR DOUBLE POLE THERMOSTAT REPLACE “T” IN MODEL NUMBER WITH “T2”
382052 AFA107D 750 2560
120
6.25
26
381994 AFA110D 1000 3413 8.3
380881 AFA115D 1500 5120 12.5
380935 AFA840D 4000 13800 208 19.2
381024 AFA848D 4800 16560 23
380942 AFA215D 1500 / 1125 5120 / 3840
240 / 208
6.2 / 5.4
380959 AFA220D 2000 / 1500 6284 / 5120 8.3 / 7.2 27
380966 AFA230D 3000 / 2250 10350 / 7763 12.5 /10.8
29
380973 AFA240D 4000 / 3000 13800 / 10350 16.7/14.4
381031 AFA248D 4800 16560 240 20
380980 AFA715D 1500 5120
277
4.1 26
380997 AFA720D 2000 6284 7.2 27
381000 AFA730D 3000 10350 10.8
29381017 AFA740D 4000 13800 14.4
381048 AFA748D 4800 16560 17.3
398077 AFA840D-3 4000 13800 208 11.11
30
398084 AFA240D-3 4800 16560 13.33
398091 AFA848D-3 4000 13800 240 9.64
398107 AFA248D-3 4800 16560 11.57
International Models
396424 M3324TD-RPi 3360/1680 11468/5734 220 15.3/7.64 27
396437 M3325TD-RPi 4032/2016 13761/6881 18.3/9.16
41
Features
Standard Models
• Powder coated bar stock steel tamper proof grille, with extruded Aluminum frame and 16
gauge housing.
• In-Built double pole tamper proof thermostat with a 40°-110°F temperature range & positive
off; 3 phase heaters have 3 pole thermostat for positive off position.
• Manual reset thermal limit switch.
• Corrosion resistant steel tubular element with brazed steel ns.
• Permanently lubricated, unit bearing, shaded pole motor with impedance protection.
• Propeller type fan blade:
1400 RPM motor; 245 CFM
• Factory installed options:
- contactors (3420 & 3450 series)
- circuit breakers (3450 series)
- control transformers (3450 series)
Manufactured in U.S.A.
Note: Wall box required - may be
ordered early for rough in purposes.
AFC & AFH Series Heavy-Duty Fan Forced Wall Heaters
HEATER WALL BOX WATTS BTU’s VOLTS PH AMPS WT.
UPC 686334 MODEL UPC 686334 MODEL
SERIES 3420 - ROUGH-IN DIMENSIONS: 19-3/8” H x 14-1/4” W x 4-1/4” D
GRILL DIMENSIONS: 21-15/32” H x 17-7/16” W
691130 AFC8120T
691574 Box 3420
2000 6826
208
1
9.6
41 lbs.
691192 AFC2120T 240 8.3
691178 AFC7120T 277 7.2
384629 AFC8380 2000 6826 208 35.6
384643 AFC2320 240 4.8
691239 AFC8130T
3000 10239
208
1
14.4
691314 AFC2130T 240 12.5
691277 AFC7130T 277 10.8
384636 AFC8330 3000 10239 208 38.3
384650 AFC2330 240 7.3
691338 AFC8140T
4000 13652
208
1
19.2
691383 AFC2140T 240 16.7
691369 AFC7140T 277 14.4
691406 AFC8340T 208 311.1
691413 AFC2340T 240 9.6
691437 AFC8150T
5000 17065
208
1
24
691512 AFC2150T 240 20.8
691482 AFC7150T 277 18.1
691536 AFC8350T 208 313.9
691567 AFC2350T 240 12.0
HEATER WALL BOX
WATTS BTU’s VOLTS PH AMPS WT.
UPC 686334 MODEL UPC 686334 MODEL
SERIES 3450 - ROUGH-IN DIMENSIONS: 23-1/16” H x 14-1/4” W x 4-1/4” D
GRILL DIMENSIONS: 25-1/32” H x 17-7/16” W
691611 AFH8120T
691918 Box 3450
2000 6826
208
1
9.6
55 lbs.
691680 AFH2120T 240 8.3
312295 AFH7120T 277 7.2
384667 AFH8320 2000 6826 208 35.6
384681 AFH2320 240 4.8
687683 AFH8130T
3000 10239
208
1
14.4
691772 AFH2130T 240 12.5
312288 AFH7130T 277 10.8
384674 AFH8330 3000 10239 208 38.3
384698 AFH2330 240 7.3
691789 AFH8140T
4000 13652
208
1
19.2
691819 AFH2140T 240 16.7
311991 AFH7140T 277 14.4
691857 AFH8340T 208 311.1
316651 AFH2340T 240 9.6
312981 AFH8150T
5000 17065
208
1
10.4
312134 AFH2150T 240 20.8
312387 AFH7150T 277 18.1
691901 AFH8350T 208 313.9
313070 AFH2350T 240 12.0
42 Product Specications
Contractor shall supply and install heavy duty wall mounted forced air electric heaters of the
wattage, voltage and phase as specied. The heater shall so be designed to provide an even
distribution of heated air to the space to be heated by drawing return air in the peripheral area of
the heater across and through the element which shall then be discharged from the center section of
the heater by means of an electric motor and axial ow fan blade. Heaters shall be recessed type to
extend no more than 1-1/2” from the nished wall or surface mounted to extend no more than 5-3/4”
from the nished wall or semi-recessed type to extend no more than 3-1/2” from nished wall or
semi-recessed type to extend no more than 2-1/2” from nished wall.
ENCLOSURE:
Heater front shall withstand 10.8 ft. lbs. (324 poundals) impact and 400 lbs. static force applied to
an 8 sq. in. area at center grille location with less than 1/16” permanent distortion. The combination
return and supply grille assembly shall be constructed of 1/16” x 3/8” rounded edge horizontal steel
louvers which shall be spaced for maximum opening of 1/4”. Louvers shall be welded at every
intersection to three evenly spaced 1/16” diameter vertical members and completely framed in a
heavy gauge natural anodized Aluminum extrusion. Front assembly shall be attached to the chassis
by hidden tamper-resistant (Allen-head) machine screws. All other parts shall be 16 gauge steel
Zinc coated, both sides nished in a high gloss or bronze colored baked powder coat nish.
MOTOR:
Motor shall be a permanently lubricated unit bearing, totally enclosed shaded pole type with
impedance protection. Motors shall operate at no more than 1400 RPM and shall be same voltage
as the heater. A protective shield shall surround the motor to separate return air from heated air.
PERFORMANCE:
Heaters shall have a rating of 245 CFM at 660 F.P.M. with a maximum temperature rise of 73°F.
ELEMENTS:
Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements
mechanically bonded to common corrosion resistant steel ns. Each sheathed element shall consist
of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded
by Magnesium Oxide, enclosed and wedged into corrosion resistant steel sheaths. Elements shall
have 2” cold conductor pins extending into the sheath and shall have a density of no more than 60
Watts per inch.
THERMAL OVERLOAD:
Heaters shall be equipped with a “manual reset” thermal overload which disconnects elements
and motor in the event normal operating temperatures are exceeded. For safety, if opened due to
abnormal temperature, thermal overload shall remain open until manually reset. Automatic reset
thermal overloads which allow the element to continue to cycle under abnormal conditions will not
be accepted.
APPROVAL:
Heaters shall be ETL Listed.
OPTIONAL CONTROL SYSTEMS:
Heaters shall be operated from wall-mounted, line voltage, heavy-duty (tamper-proof) thermostats.
Heaters with built-in, pre-wired contactors shall be operated from wall-mounted, line voltage, pilot
duty (tamper-proof) thermostats. Heaters built with, pre-wired contactors (and control transformers)
shall be operated from wall-mounted, pilot duty (24V) or (120V) wall-mounted tamper-proof
thermostats. Heaters shall be controlled by integrally mounted thermostats. Thermostats shall be
heavy-duty, hydraulic type with a range of 40°F to 80°F and with remote sensing bulb placed in the
return air. Thermostats shall be electrically rated at least 125% of heater rating. Thermostats
AFC & AFH Series Heavy-Duty Fan Forced Wall Heaters
43
Field Installed Accessories
Units with transformers must have a contactor. A control transformer with 120V secondary is available on all 3-phase
models, 208V/240V 1-phase units up to 3KW, and up to 4 KW on 277V. All heaters must be installed with a wall box.
shall be heavy-duty, hydraulic type with a range of 40°F to 80°F and with remote sensing bulb placed
in the return air. Thermostats shall be electrically rated at least 125% of heater rating. Thermostats
shall also act as a disconnect by breaking all ungrounded conductors in the OFF position. (Thermostat
control knob shall be covered by a 16 gauge tamper-proof access plate to prevent adjustment by
unauthorized personnel.)
CONTACTORS:
Where required, heaters shall be equipped with heavy-duty, denite purpose contactors with ame
path separators and dust covers. Contactors shall cycle all ungrounded conductors. Contactors shall
have holding coils (of the same voltage as the heater) or (120 Volts) or (24 Volts).
CONTROL TRANSFORMERS:
Heater shall be equipped with a Class 2 control transformer, sealed rating of 20 VA, to supply
control circuits of (24 Volts) or (120 Volts). (120 Volt secondaries not available in single phase
heaters over 3 KW).
CIRCUIT BREAKERS (3450 Series Only):
Heaters shall be equipped with built-in circuit breakers in order to allow the heaters to be supplied
from feeder taps. A separate switch providing a positive off for control circuits shall be included
where required. Circuit breakers and control switches shall be arranged so that all line side conductors
will be separately enclosed when heater front is removed for servicing so that no current carrying
parts are accessible without the use of additional tools.
Product Specications
MODEL DESCRIPTION SERIES OPTIONS
AFC AFH
Sufx - R Contactor with Coil same as heater YES YES
Sufx - R1 Contactor with 24V Coil YES YES
Sufx - R2 Contactor with 120V Coil YES YES
Sufx - C Circuit Breakers - all models NO YES
Sufx - A1* Control Transformers With 24V Secondary NO YES
Sufx - A2* Control Transformers With 120V Secondary NO YES
UPC#
686334 MODEL DESCRIPTION WT.
329095 AFCEX34 4” Surface Mounting Sleeve 6 lb.
329101 AFCEX16 2” Semi-Recessing Sleeve 4 lb.
329118 AFCEX8 1” Semi-Recessing Sleeve 4 lb.
329125 AFHEX34 4” Surface Mounting Sleeve 5 lb.
329132 AFHEX16 2” Semi-Recessing Sleeve 4 lb.
329149 AFHEX8 1” Semi-Recessing Sleeve 3 lb.
AFC & AFH Series Heavy-Duty Fan Forced Wall Heaters
44
3310 Series Fan Forced Wall Heater - Without Summer Fan Switch
Standard Models
Features
Manufactured in U.S.A.
• Powder coated 18 gauge steel front.
• Automatic reset thermal limit.
• Vane axial fan blade: 600 RPM / 175 CFM.
• Rough in dimensions: 14-3/16” Wide x 19-15/16” High x 4” Deep.
• Grill dimensions: 15-3/8” Wide x 20-9/64” High.
• Steel block n element.
• Weight 22 lbs.
• Units with dual wattage, factory wired to highest wattage.
• Wattage selectable at time of installation on some models.
MODELS WITH IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90º F TEMPERATURE RANGE)
IVORY WHITE
WATT S MAX
BTU’s VOLTS AMPS
UPC
686334
IVORY
MODEL
UPC
686334
WHITE
MODEL
326346 E3312T2RP 326483 E3312T2RPW 1000 3413
120
8.3
326353 E3313T2RP 326490 E3313T2RPW 1500 5120 12.5
750 2560 6.25
326360 F3316T2RP 326506 F3316T2RPW 4000 13648 208 19.2
326377 F3317T2RP 326513 F3317T2RPW 4800 16380 23
326407 HF3315T2RP 326544 HF3315T2RPW 3000 / 2250 10240
240 / 208
12.5 / 10.8
1500 / 1125 5120 6.2 / 5.4
326414 HF3316T2RP 326551 HF3316T2RPW 4000 / 3000 13648 16.8 / 14.4
2000 / 1500 6826 8.3 / 7.2
326421 H3317T2RP 326568 H3317T2RPW 4800 16380 240 20.0
326438 G3314T2RP 326575 G3314T2RPW 2000 6826
277
7.2
326445 G3315T2RP 326582 G3315T2RPW 3000 10240 10.8
326452 G3316T2RP 326599 G3316T2RPW 4000 13648 14.4
326469 G3317T2RP 326605 G3317T2RPW 4800 16380 17.3
MODELS WITH IN-BUILT SINGLE POLE THERMOSTAT (50º - 90º F TEMPERATURE RANGE)
382526 E3312TRP 382618 E3312TRPW 1000 3413
120
8.3
380652 E3313TRP 384162 E3313TRPW 1500 5120 12.5
750 2560 6.25
379946 F3316TRP 384186 F3316TRPW 4000 13648 208 19.2
380300 F3317TRP 384193 F3317TRPW 4800 16380 23
380560 HF3315TRP 382229 HF3315TRPW 3000 / 2250 10240
240 / 208
12.5 / 10.8
1500 / 1125 5120 6.2 / 5.4
379984 HF3316TRP 382236 HF3316TRPW 4000 / 3000 13648 16.8 / 14.4
2000 / 1500 6826 8.3 / 7.2
380317 H3317TRP 382243 H3317TRPW 4800 16380 240 20.0
329873 G3314TRP 384261 G3314TRPW 2000 6826
277
7.2
328494 G3315TRP 328517 G3315TRPW 3000 10240 10.8
328500 G3316TRP 328524 G3316TRPW 4000 13648 14.4
379179 G3317TRP 384292 G3317TRPW 4800 16380 17.3
MODELS WITHOUT AN IN-BUILT THERMOSTAT
326629 E3312RP 326766 E3312RPW 1000 3413
120
8.3
326636 E3313RP 326773 E3313RPW 1500 5120 12.5
750 2560 6.25
328531 F3316RP 326780 F3316RPW 4000 13648 208 19.2
326650 F3317RP 326797 F3317RPW 4800 16380 23
326681 HF3315RP 326827 HF3315RPW 3000 / 2250 10240
240 / 208
12.5 / 10.8
1500 / 1125 5120 6.2 / 5.4
326698 HF3316RP 326834 HF3316RPW 4000 / 3000 13648 16.8 / 14.4
2000 / 1500 6826 8.3 / 7.2
326704 H3317RP 326841 H3317RPW 4800 16380 240 20.0
326711 G3314RP 326858 G3314RPW 2000 6826
277
7.2
326728 G3315RP 326865 G3315RPW 3000 10240 10.8
326735 G3316RP 326872 G3316RPW 4000 13648 14.4
326742 G3317RP 326889 G3317RPW 4800 16380 17.3
45
3310 Series Fan Forced Wall Heater - With Summer Fan Switch
Standard Models
Accessories - All Models
• Powder coated 18 gauge steel front.
• Automatic reset thermal limit.
• Steel block n element.
• Weight 22 lbs.
• Vane axial fan blade: 600 RPM / 175 CFM.
• Grill dimensions: 15-3/8” Wide x 20-9/64” High.
• Rough in dimensions: 14-3/16” Wide x 19-15/16” High x 4” Deep.
• Units with dual wattage, factory wired to highest wattage.
• Wattage selectable at time of installation on some models.
Typical Specications: Furnish and install Electric Forced Air Heaters where
specied. The heaters shall be constructed of a heavy gauge steel housing. The
rough-in dimensions are 14-3/16” Wide x 19-5/16” High x 4” Deep. The nish
shall be powder coated paint in ivory or white color. The units shall be available in
ratings from 750 through 4800 Watts. The heaters shall have a low speed 600 RPM
motor which drives a vane axial blower to deliver a quiet 175 CFM of down ow air. The heating element shall be
of the sealed block n type with large, parallel steel ns for quick heat transfer. Unit shall have a standard thermal
overload cutoff for added safety, a fan switch for fan only operation, and is available with a single pole, or double pole
built-in thermostat, or no thermostat. The in-built thermostat shall be calibrated to provide a range of 50 degrees F. to
90 degrees F. All heaters shall be listed by ETL. The heating element shall be supplied with a manufacturer’s 1 year
limited warranty.
Features
Product Specications
Manufactured in U.S.A.
Note: Fan switch not available on 277V models. 277V models are available without a fan switch on previous page.
IVORY WHITE
DESCRIPTION ACCESSORY TYPE
UPC MODEL UPC MODEL
686334 686334
377850 BOX3310 377850 BOX3310 ADDITIONAL BACK CAN Field Installed
329958 3310EX33R 329965 3310EX33WR SURFACE MOUNTING FRAME
SUFFIX D DISCONNECT SWITCH Factory Installed
MODELS WITH IN-BUILT DOUBLE POLE THERMOSTAT (50º - 90ºF TEMPERATURE RANGE)
IVORY WHITE
WATTS MAX BTU’s VOLTS AMPS
UPC IVORY UPC WHITE
686334 686334
326063 E3312T2SRP 326209 E3312T2SRPW 1000 3413
120
8.3
326070 E3313T2SRP 326216 E3313T2SRPW 1500 5120 12.5
750 2560 6.25
326087 F3316T2SRP 326223 F3316T2SRPW 4000 13648 208 19.2
326094 F3317T2SRP 326230 F3317T2SRPW 4800 16380 23
326124 HF3315T2SRP 326261 HF3315T2SRPW 3000 / 2250 10240
240 / 208
12.5 / 10.8
1500 / 1125 5120 6.2 / 5.4
326131 HF3316T2SRP 326278 HF3316T2SRPW 4000 / 3000 13648 16.8 / 14.4
2000 / 1500 6826 8.3 / 7.2
326148 H3317T2SRP 326285 H3317T2SRPW 4800 16380 240 20.0
MODELS WITH IN-BUILT SINGLE POLE THERMOSTAT (50º - 90ºF TEMPERATURE RANGE)
382571 E3312TSRP 382595 E3312TSRPW 1000 3413
120
8.3
379618 E3313TSRP 384018 E3313TSRPW 1500 5120 12.5
750 2560 6.25
377713 F3316TSRP 384025 F3316TSRPW 4000 13648 208 19.2
377782 F3317TSRP 384032 F3317TSRPW 4800 16380 23
377607 HF3315TSRP 384070 HF3315TSRPW 3000 / 2250 10240
240 / 208
12.5 / 10.8
1500 / 1125 5120 6.2 / 5.4
377690 HF3316TSRP 384087 HF3316TSRPW 4000 / 3000 13648 16.8 / 14.4
2000 / 1500 6826 8.3 / 7.2
377768 H3317TSRP 384094 H3317TSRPW 4800 16380 240 20.0
International Models
---- ---- 396480 M3315T2SRPWi 3360 11468
220
15.27
1680 5734 7.64
---- ---- 396493 M3316T2SRPWi 4032 13761 18.33
2016 6881 9.16
46 • Units have white powder coat nish.
• Approved for horizontal mounting - right or left discharge.
• Drywall depth embossments on back can.
• Powder coated 18 gauge steel front.
• Manual reset thermal limit.
• Finned tubular steel element.
• Weight 6 lbs.
• Propeller style fan blade: 2200 RPM / 70 CFM.
• Optional eld installed In-Built thermostat.
• Rough in dimensions: 9-1/4” Wide, 12-1/8” High, 3-5/8” Deep.
• Grill dimensions: 9-25/32” Wide, 13” High.
3200 Series Midsized Fan Forced Wall Heater - With Wall Box
“TWO WIRE INSTALLATION”
Features
Standard Models
Accessories
Manufactured in U.S.A.
FIELD INSTALLED COMPONENTS
UPC MODEL DESCRIPTION
686334
383646 32T1 Single Pole thermostat with positive off for
120V units 50o - 90o F
383653 32T2 Double Pole thermostat with positive off for
240/208V units 50o - 90o F
SURFACE MOUNTED EXTENDERS & FRAMES
WHITE
DESCRIPTION
UPC
686334 MODEL
996976 303EX8RW 1” EXTENDER
996969 303EX16RW 2” EXTENDER
996952 303EX32RW 4” SURFACE MOUNT FRAME
UPC MODEL VOLTS WATTS MAX AMPS
686334 BTU’S
BUILT-IN DOUBLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE
383462 F3220T2RPW 208 2000 6826 9.6
383479 H3275T2RPW 240 750 2560 3.1
383486 HF3210T2RPW
240/208
1000 / 750 3413 / 2560 4.2 / 3.6
383493 HF3215T2RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
383509 HF3220T2RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
383516 HF3222T2RPW 2250 / 1688 7680 / 5762 9.4 / 8.1
International Models - BUILT-IN DOUBLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE
396387 M3210T2RPWi
220
840 2867 3.8
396394 M3215T2RPWi 1260 4300 5.7
396400 M3220T2RPWi 1680 5734 7.6
396417 M3222T2RPWi 1890 6451 8.6
Standard Models - BUILT-IN SINGLE POLE (POSITIVE OFF) THERMOSTAT 50° - 90° F RANGE
383523 E3275TRPW
120
750 2560 6.25
383530 E3210TRPW 1000 3413 8.33
383547 E3215TRPW 1500 5120 12.5
NO BUILT-IN THERMOSTAT
383554 E3275RPW
120
750 2560 6.25
383561 E3210RPW 1000 3413 8.33
383578 E3215RPW 1500 5120 12.5
383585 F3220RPW 208 2000 6826 9.6
383592 H3275RPW 240 750 2560 3.1
383608 HF3210RPW
240/208
1000 / 750 3413 / 2560 4.2 / 3.6
383615 HF3215RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
383622 HF3220RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
383639 HF3222RPW 2250 / 1688 7680 / 5762 9.4 / 8.1
47
4300 Series Low Prole Fan Forced Wall Heater - With Wall Box
• Available in ivory or white.
• Powder coated 20 gauge steel front.
• Manual reset thermal limit.
• Finned tubular steel element.
• Weight 9 lbs.
• Propeller style fan blade - 2200 RPM / 70 CFM
• Rough in dimensions: 14-1/2” Wide, 7-1/8” High,
3-1/2” Deep
• Grill dimensions: 16-3/4” Wide, 7-5/8” High
• Unit not approved for ceiling mount applications.
• Unit can be positioned to allow left, right or top discharge.
Standard Models
Accessories
Features
Manufactured in U.S.A.
UPC
686334
IVORY
MODEL
UPC
686334
WHITE
MODEL ACCESSORY OPTIONS WT.
LBS.
327657 4300EX8 328456 4300EX8W 1” SEMI RECESSING EXTENDER 2
327664 4300EX16 328463 4300EX16W 2” SEMI RECESSING EXTENDER 3
327671 4300EX32 328470 4300EX32W 4” SURFACE MOUNTING FRAME 4
327688 4300P 328487 4300PW WALL PLATE ADAPTOR (OD 21.5” x 12.25”) 1
FIELD INSTALLED THERMOSTATS 329774 43T SINGLE POLE THERMOSTAT 50O - 90O F 1
329781 43T2 DOUBLE POLE THERMOSTAT 50O - 90O F 1
IVORY WHITE
VOLTS WATTS MAX BTU’s AMPS
UPC
686334 MODEL UPC
686334 MODEL
DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50° - 90°F)
327695 F4320T2RP 327749 F4320T2RPW 208 2000 6826 9.6
327701 HF4375T2RP 327756 HF4375T2RPW
240/208
750 / 562 2560 / 1920 3.1 / 2.7
327718 HF4310T2RP 327763 HF4310T2RPW 1000 / 750 3413 / 2560 4.2 / 3.6
327725 HF4315T2RP 327770 HF4315T2RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
327732 HF4320T2RP 327787 HF4320T2RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
International Models - DOUBLE POLE IN-BUILT THERMOSTAT (RANGE 50° - 90°F)
---- ---- 396448 M4375T2RPi
220
630 2150 2.9
---- ---- 396455 M4310T2RPi 840 2869 3.8
---- ---- 396462 M4315T2RPi 1260 4300 5.7
---- ---- 396479 M4320T2RPi 1680 5733 7.6
Standard Models - SINGLE POLE INBUILT THERMOSTAT (RANGE 50° - 90°F)
327794 E4375TRP 327879 E4375TRPW
120
750 2560 6.25
327800 E4310TRP 327886 E4310TRPW 1000 3413 8.33
327817 E4315TRP 327893 E4315TRPW 1500 5120 12.5
327824 F4320TRP 327909 F4320TRPW 208 2000 6826 9.6
327831 HF4375TRP 327916 HF4375TRPW
240/208
750 / 562 2560 / 1920 3.1 / 2.7
327848 HF4310TRP 327923 HF4310TRPW 1000 / 750 3413 / 2560 4.2 / 3.6
327855 HF4315TRP 327930 HF4315TRPW 1500 / 1125 5120 / 3840 6.3 / 5.4
327862 HF4320TRP 327947 HF4320TRPW 2000 / 1500 6826 / 5120 8.3 / 7.2
NO IN-BUILT THERMOSTAT
327954 E4375RP 328036 E4375RPW
120
750 2560 6.25
327961 E4310RP 328043 E4310RPW 1000 3413 8.33
327978 E4315RP 328050 E4315RPW 1500 5120 12.5
327985 F4320RP 328067 F4320RPW 208 2000 6826 9.6
327992 HF4375RP 328074 HF4375RPW
240/208
750 / 562 2560 / 1920 3.1 / 2.7
328005 HF4310RP 328081 HF4310RPW 1000 / 750 3413 / 2560 4.2 / 3.6
328012 HF4315RP 328098 HF4315RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
328029 HF4320RP 328104 HF4320RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
48
4800 Series Register Style Fan Forced Wall Heater - With Wall Box
Features
• Units have white powder coat nish.
• Powder coated 20 gauge steel front.
• Manual reset thermal limit.
• Finned tubular steel element.
• Propeller style fan blade - 2200 RPM / 70 CFM.
• Weight 9 lbs.
• Rough in dimensions: 14-1/2” Wide x 7-1/8” High x 3-1/2” Deep.
• Grill dimensions: 16-3/4” Wide x 7-5/8” High.
• Unit not approved for ceiling mount applications.
• Left discharge only.
Accessories
Standard Models
Manufactured in U.S.A.
UPC MODEL VOLTS WATTS MAX AMPS
686334 BTU’S
DOUBLE POLE IN-BUILT THERMOSTAT (40º - 110º F TEMPERATURE RANGE)
328159 F4820T2RPW 208 2000 6826 9.6
328166 HF4875T2RPW
240/208
750 / 562 2560 / 1920 3.1 / 2.7
328173 HF4810T2RPW 1000 / 750 3413 / 2560 4.2 / 3.6
328180 HF4815T2RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
328197 HF4820T2RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
SINGLE POLE IN-BUILT THERMOSTAT (50º - 90º F TEMPERATURE RANGE)
328203 E4875TRPW
120
750 2560 6.25
328210 E4810TRPW 1000 3413 8.33
328227 E4815TRPW 1500 5120 12.5
328234 F4820TRPW 208 2000 6826 9.6
NO IN-BUILT THERMOSTAT
328241 E4875RPW
120
750 2560 6.25
328258 E4810RPW 1000 3413 8.33
328265 E4815RPW 1500 5120 12.5
328272 F4820RPW 208 2000 6826 9.6
328289 HF4875RPW
240/208
750 / 562 2560 / 1920 3.1 / 2.7
328296 HF4810RPW 1000 / 750 3413 / 2560 4.2 / 3.6
328302 HF4815RPW 1500 / 1125 5120 / 3840 6.3 / 5.4
328319 HF4820RPW 2000 / 1500 6826 / 5120 8.3 / 7.2
UPC#
686334 MODEL DESCRIPTION WT. LBS.
328456 4300EX8W 1” SEMI RECESSING EXTENDER 2
328463 4300EX16W 2” SEMI RECESSING EXTENDER 3
328470 4300EX32W 4” SURFACE MOUNTING FRAME 4
328487 4300PW WALL PLATE ADAPTOR (OD 21.5” x 12.25”) 1
329774 43T SINGLE POLE THERMOSTAT 50O - 90O F 1
329798 48T2 DOUBLE POLE THERMOSTAT 50O - 90O F 1
49
4.10
2.42
WIRE NUT
TEMPERATURE LIMITING DEVICE
1.43
2.1
1.60
8.50”
3.00”
3900 Series Hydronic Electric Baseboard Heater
Standard Models
Product Specications & Dimensions
The entire heater casing shall be
constructed of 6063 extruded Aluminum.
minimum thickness of .100” (12 gauge) Aluminum
shall be acceptable. Outlet grill shall cover entire
length of air discharge opening and be constructed
of steel. All casing and grill construction shall be
painted with high quality durable powder coated
paint.
The heating element shall be high quality
Nichrome wire encased in Magnesium Oxide and
sealed in copper tube. The heating element shall
be sealed in .312” diameter Copper tube and be
immersed in heat transfer liquid. Aluminum ns
shall be mechanically bonded to the entire heated
length of the element for even heat transfer.
Linear automatic thermal limit shall
extend the entire heater length of element and
protect heater in case of an over-temperature
condition.
Optional controls shall be mounted in junction box enclosures at either end of heater. Optional integral thermostat shall be
located in junction box with adjustment knob or for tamper-proof operation. Optional disconnect switch shall be mounted in junction box.
Optional 120 Volt or air conditioning receptacle shall be mounted in junction box.
Optional installation accessories shall include inside and outside corner sections for complete wall perimeter t. Prole of
corners and grill shall have appearance of heat sections for continuous architectural design. Corner accessories and heater sections shall
be secured by alignment pins for easy alignment of multiple heater applications.
• Permanent mount self contained unit.
• Heating elements are immersed in a heat transferring liquid enclosed
by a Copper tube casing with Aluminum ns.
• Powder coated 12 gauge heavy duty extruded Aluminum housing with
junction boxes located on each end of the unit.
• Automatic linear limit.
• Wire guard extends along the entire outlet area of the baseboard.
• Commercial Brown unit has in-built wireway.
• Special colors available, consult factory.
• Suitable for high altitude applications.
• 1 Year element warranty.
Manufactured in U.S.A.
STANDARD WHITE COMMERCIAL BROWN
WATTS BTU’S. VOLTS AMPS HEATER
LENGTH (IN.)
WT.
(LBS)
UPC MODEL UPC MODEL
686334 686334
111416 E3904-28 111645 E3904-28C 400 1360 120 3.3
28 16
111423 F3904-28 111652 F3904-28C 400 1360 208 1.92
111430 H3904-28 111669 H3904-28C 400/300 1360/1024 240/208 1.6/1.4
111447 G3904-28 111676 G3904-28C 400/300 1360 277/240 1.4
111454 E3906-36 111683 E3906-36C 600 2048 120 5
36 22
111461 F3906-36 111690 F3906-36C 600 2048 208 2.9
111478 H3906-36 111706 H3906-36C 600/450 2048/1536 240/208 2.5/2.2
111485 G3906-36 111713 G3906-36C 600/450 2048 277/240 2.2
111492 E3910-48 111720 E3910-48C 1000 3413 120 8.3
48 27
111508 F3910-48 111737 F3910-48C 1000 3413 208 4.8
111515 H3910-48 111744 H3910-48C 1000/750 3413/2560 240/208 4.2/3.6
111522 G3910-48 111751 G3910-48C 1000/750 3413 277/240 3.6
111539 E3912-60 111768 E3912-60C 1250 4265 120 10.4
60 33
111546 F3912-60 111775 F3912-60C 1250 4265 208 6
111553 H3912-60 111782 H3912-60C 1250/938 4265/3201 240/208 5.2/4.5
111560 G3912-60 111799 G3912-60C 1250/938 4265 277/240 3.6
111577 E3915-72 111805 E3915-72C 1500 5100 120 12.5
72 41
111584 F3915-72 111812 F3915-72C 1500 5100 208 7.2
111591 H3915-72 111829 H3915-72C 1500/1125 5100/3825 240/208 6.3/5.4
111607 G3915-72 111836 G3915-72C 1500/1125 5100 277/240 5.4
111614 F3920-96 111842 F3920-96C 2000 6826 208 9.6
96 58111621 H3920-96 111850 H3920-96C 2000/1500 6826/5100 240/208 8.3/7.2
111638 G3920-96 111867 G3920-96C 2000/1500 6826 277/240 7.2
50
3700 Series Architectural Style Electric Baseboard Heater
Standard Models Product Specications
Note: Refer to 3900 Series for product dimension specications.
Manufactured in U.S.A.
• Available in white or brown with stainless steel heating element and
aluminum ns.
• Powder coated 12 gauge heavy duty extruded Aluminum housing
construction with junction boxes located on each end of the unit.
• An automatic thermal linear limit is used along the entire heated length
of the unit.
• Wire guard extends along the entire outlet area of the baseboard.
• Special colors available, consult factory.
The entire heater casing
shall be constructed of
6063 extruded Aluminum.
Minimum thickness of .100”
(12 gauge) Aluminum shall
be acceptable. Outlet grill
shall cover entire length of
air discharge opening and be
constructed of steel. All casing
and grill construction shall
be painted with high quality
durable powder coated paint.
The heating element
shall be high quality nichrome
wire encased in Magnesium
Oxide and sealed in a stainless
steel tube.
Linear automatic
thermal limit shall extend the
entire heater length of element
and protect heater in case of an
over-temperature condition.
Optional controls
shall be mounted in junction
box enclosures at either end
of heater. Optional integral
thermostat shall be located in
junction box with adjustment
knob or for tamper-proof
operation. Optional disconnect
switch shall be mounted
in junction box. Optional
120 Volt or air conditioning
receptacle shall be mounted in
junction box.
Optional installation
accessories shall include
inside and outside corner
sections for complete wall
perimeter t. Prole of corners
and grill shall have appearance
of heat sections for continuous
architectural design. Corner
accessories and heater sections
shall be secured by alignment
pins for easy alignment of
multiple heater applications.
STANDARD WHITE COMMERCIAL BROWN
WATTS BTU’s VOLTS AMPS
HEATER
LENGTH
(IN.)
WT.
(LBS.)
UPC
686334 MODEL UPC
686334 MODEL
116008 E3703-024 116435 E3703-024B 375 1275 120 3.1
24 14
116015 F3703-024 116442 F3703-024B 375 1275 208 1.8
116022 H3703-024 116459 H3703-024B 375 / 281 1275 / 955 240 / 208 1.6/1.4
116039 G3703-024 116466 G3703-024B 375 / 281 1275 / 955 277 / 240 1.6/1.2
116046 E3705-028 116473 E3705-028B 500 1706 120 4.2
28 16
116053 F3705-028 116480 F3705-028B 500 1706 208 2.4
116060 H3705-028 116497 H3705-028B 500 / 375 1706 / 1275 240 / 208 2.1/1.8
116077 G3705-028 116503 G3705-028B 500 / 375 1706 / 1275 277 / 240 1.8/1.6
116084 E3706-036 116510 E3706-036B 600 2040 120 5
36 22
116091 F3706-036 116527 F3706-036B 600 2040 208 2.9
116107 H3706-036 116534 H3706-036B 600 / 450 2040 / 1530 240 / 208 2.5/2.2
116114 G3706-036 116541 G3706-036B 600 / 450 2040 / 1530 277 / 240 2.2/1.9
116121 E3707-040 116558 E3707-040B 750 2550 120 6.3
40 27
116138 F3707-040 116565 F3707-040B 750 2550 208 3.6
116145 H3707-040 116572 H3707-040B 750 / 563 2550 / 1914 240 / 208 3.1/2.7
116152 G3707-040 116589 G3707-040B 750 / 563 2550 / 1914 277 / 240 2.7.2.6
116169 E3710-048 116596 E3710-048B 1000 3413 120 8.3
48 31
116176 F3710-048 116602 F3710-048B 1000 3413 208 4.8
116183 H3710-048 116619 H3710-048B 1000 / 750 3413 / 2550 240 / 208 4.2/3.6
116190 G3710-048 116626 G3710-048B 1000 / 750 3413 / 2550 277 / 240 3.6/3.1
116206 G3707-048 116633 G3707-048B 750 2550 277 3.4
116213 E3712-060 116640 E3712-060B 1250 4250 120 10.4
60 33
116220 F3712-060 116657 F3712-060B 1250 4250 208 6
116237 H3712-060 116664 H3712-060B 1250 / 938 4250 / 3189 240 / 208 5.2/4.5
116244 G3712-060 116671 G3712-060B 1250 / 938 4250 / 3189 277 / 240 4.5/3.9
116251 G3709-060 116688 G3709-060B 938 3189 277 3.4
116268 E3715-072 116695 E3715-072B 1500 5100 120 12.5
72 41
116275 F3715-072 116701 F3715-072B 1500 5100 208 7.2
116282 H3715-072 116718 H3715-072B 1500 / 1125 5100 / 3825 240 / 208 6.3/4.7
116299 G3715-072 116725 G3715-072B 1500 / 1125 5100 / 3825 277 / 240 5.4/4.7
116305 G3711-072 116732 G3711-072B 1125 3825 277 4.1
116312 F3717-084 116749 F3717-084B 1750 5950 208 8.4
84 49
116329 H3717-084 116756 H3717-084B 1750 / 1313 5950 / 4464 240 / 208 7.3/6.3
116336 G3717-084 116763 G3717-084B 1750 / 1313 5950 / 4464 277 / 240 6.3/5.5
116343 G3713-084 116770 G3713-084B 1313 4464 277 4.7
116350 F3720-096 116787 F3720-096B 2000 6826 208 9.6
96 58
116367 H3720-096 116794 H3720-096B 2000 / 1500 6826 / 5100 240 / 208 8.3/7.2
116374 G3720-096 116800 G3720-096B 2000 / 1500 6826 / 5100 277 / 240 7.2/6.3
116381 G3715-096 116817 G3715-096B 1500 5100 277 5.4
116398 F3725-120 116824 F3725-120B 2500 8532 208 12
120 67
116404 H3725-120 116831 H3725-120B 2500 / 1875 8532 / 6375 240 / 208 10.4/9.0
116411 G3725-120 116848 G3725-120B 2500 / 1875 8532 / 6375 277 / 240 9.0/7.8
116428 G3718-120 116855 G3718-120B 1875 6375 277 6.8
51
4.10
2.42
WIRE NUT
TEMPERATURE LIMITING DEVICE
1.43
2.1
1.60
8.50”
3.00”
Hydronic & Architectural Electric Baseboard Heater Accessories
Field Installed Accessories
Baseboard Sections
Wireway Covers (White Units Only)
Dimension
OUTSIDE
CORNER
INSIDE
CORNER
Outside and inside corner
sections are 6” on longest side
DESCRIPTION
Standard White Commercial Brown
UPC#
686334 MODEL UPC#
686334 MODEL
Single Pole, In-Built T-Stat, 22A @ 120-240V; 18A @ 277V; 50°-90° F 111874 3900T1 111959 3900T1C
Double Pole, In-Built T-Stat, 22A @ 120-240V; 18A @ 277V; 50°-90° F 111881 3900T2 111966 3900T2C
Air Conditioning Receptacle Section, 20 Amp @ 125-277V 111898 3900AC 111997 3900ACC
120V. Receptacle Section, 15 Amp 111904 3900REC 112000 3900RECC
Disconnect Switch, 20 Amp @ 125-277VAC; DPST 111942 3900DS 112048 3900DSC
STANDARD WHITE COMMERCIAL BROWN DESCRIPTION
UPC#
686334 MODEL UPC#
686334 MODEL SECTION SIZE
112154 39BS28 112215 39BS28C
Blank Section
28”
112161 39BS36 112222 39BS36C 36”
112178 39BS48 112239 39BS48C 48”
112185 39BS60 112246 39BS60C 60”
112192 39BS72 112253 39BS72C 72”
112208 39BS96 112260 39BS96C 96”
115094 39BS120 115100 39BS120C 120”
111911 3900-ICS 112017 3900-ICSC Inside Corner
-
111928 3900-OCS 112024 3900-OCSC Outside Corner
111935 3900-CS 112031 3900-CSC Control Section 4” Blank
UPC#
686334 MODEL LENGTH SHIP WT.
(LBS)
112284 3900WW28 28” 2
112291 3900WW36 36” 2.5
112307 3900WW48 48” 3.5
112314 3900WW60 60” 4.5
112321 3900WW72 72” 5.5
112338 3900WW96 96” 7.5
115117 3900WW120 120” 7.5
52
Wireway Length Same As Baseboard Length
2900HA Series Electric Baseboard - High Altitude Convection Heater
• Available in white or ivory with Aluminum heating element and Aluminum ns.
• Painted 22 gauge steel front with 20 gauge junction boxes located on each end
of the heater - junction boxes contain quick connect cable clamps and 6” ground
lead wires.
• Over-temperature thermal limit extends entire length of heated area.
• A full length wireway provided along the back of the heater.
• Optional enclosed conduit wireway available.
• Heater can be mounted to the wall by using the key hole knockouts every 4” at the
back of the heater.
• Optional In-Built thermostats eld installed in the junction box.
• HEIGHT: 6” DEPTH: 2-1/2”
• Ivory available with extended lead times-consult factory.
Features
Standard Models
Manufactured in U.S.A.
2900A Series - International Models
UPC# 686334 WHITE MODEL WATTS BTU’s VOLTS HEATER LENGTH (IN) WEIGHT (LBS)
115766 M2903-24AWi 375 1275 220 24” 10
115773 H2903-24AWi 240
115780 M2905-28AWi 500 1706 220 28” 11
115977 H2905-28AWi 240
115803 M2906-36AWi 600 2040 220 36” 11.5
115810 H2906-36AWi 240
115827 M2907-40AWi 750 2550 220 40” 13
115834 H2907-40AWi 240
115841 M2910-48AWi 1000 3413 220 48” 14
115858 H2910-48AWi 240
115865 M2912-60AWi 1250 4250 220 60” 16
115872 H2912-60AWi 240
115889 M2915-72AWi 1500 5100 220 72” 19
115896 H2915-72AWi 240
115902 M2917-84AWi 1750 5950 220 80” 22
118002 H2917-84AWi 240
118033 M2925-120AWi 2500 8532 220 120” 31
118040 H2920-120AWi 240
UPC#
686334
WHITE
MODEL WATTS BTU’s VOLTS AMPS HEATER
LENGTH (IN)
WT.
(LBS.)
101226 E2903-024HAW 375 1275 120 3.1
24 5
101233 F2903-024HAW 375 1275 208 1.8
101240 H2903-024HAW 375 / 281 1275 / 955 240 / 208 1.6/1.4
101257 G2903-024HAW 375 / 281 1275 / 955 277 / 240 1.6/1.2
101264 E2905-028HAW 500 1706 120 4.2
28 6
101271 F2905-028HAW 500 1706 208 2.4
101288 H2905-028HAW 500 / 375 1706 / 1275 240 / 208 2.1/1.8
101295 G2905-028HAW 500 / 375 1706 / 1275 277 / 240 1.8/1.6
101301 E2906-036HAW 600 2040 120 5
36 7
101318 F2906-036HAW 600 2040 208 2.9
101325 H2906-036HAW 600 / 450 2040 / 1530 240 / 208 2.5/2.2
101332 G2906-036HAW 600 / 450 2040 / 1530 277 / 240 2.2/1.9
101349 E2907-040HAW 750 2550 120 6.3
40 8
101356 F2907-040HAW 750 2550 208 3.6
101363 H2907-040HAW 750 / 563 2550 / 1914 240 / 208 3.1/2.7
101370 G2907-040HAW 750 / 563 2550 / 1914 277 / 240 2.7.2.6
101387 E2910-048HAW 1000 3413 120 8.3
48 10
101394 F2910-048HAW 1000 3413 208 4.8
101400 H2910-048HAW 1000 / 750 3413 / 2550 240 / 208 4.2/3.6
101417 G2910-048HAW 1000 / 750 3413 / 2550 277 / 240 3.6/3.1
101424 G2907-048HAW 750 2550 277 3.4
101431 E2912-060HAW 1250 4250 120 10.4
60 12
101448 F2912-060HAW 1250 4250 208 6
101455 H2912-060HAW 1250 / 938 4250 / 3189 240 / 208 5.2/4.5
101462 G2912-060HAW 1250 / 938 4250 / 3189 277 / 240 4.5/3.9
101479 G2909-060HAW 938 3189 277 3.4
101486 E2915-072HAW 1500 5100 120 12.5
72 14
101493 F2915-072HAW 1500 5100 208 7.2
101509 H2915-072HAW 1500 / 1125 5100 / 3825 240 / 208 6.3/4.7
101516 G2915-072HAW 1500 / 1125 5100 / 3825 277 / 240 5.4/4.7
101523 G2911-072HAW 1125 3825 277 4.1
101578 F2920-096HAW 2000 6826 208 9.6
96 18
101585 H2920-096HAW 2000 / 1500 6826 / 5100 240 / 208 8.3/7.2
101592 G2920-096HAW 2000 / 1500 6826 / 5100 277 / 240 7.2/6.3
101608 G2915-096HAW 1500 5100 277 5.4
101653 F2925-120HAW 2500 8532 208 12
120 22
101660 H2925-120HAW 2500 / 1875 8532 / 6375 240 / 208 10.4/9.0
101677 G2925-120HAW 2500 / 1875 8532 / 6375 277 / 240 9.0/7.8
101684 G2918-120HAW 1875 6375 277 6.8
53
2900S Series Electric Baseboard - Stainless Steel Element Convection Heater
• Available in white or ivory with stainless steel heating element and Aluminum
ns.
• Painted 22 gauge steel front with 20 gauge junction boxes located on each end
of the heater - junction boxes contain quick connect cable clamps and 6”ground
lead wires.
• Over-temperature thermal limit extends entire length of heated area.
• A full length wireway provided along the back of the heater - enclosed conduit
available.
• Heater can be mounted to the wall by using the key hole knockouts every 4” at
the back of the heater.
• Optional In-Built thermostats eld installed in the junction box.
• HEIGHT: 6” DEPTH: 2-1/2”
Features
Standard Models
Manufactured in U.S.A.
UPC IVORY UPC WHITE WATTS BTU’s VOLTS AMPS
HEATER
LENGTH
(IN)
WT.
686334 MODEL 686334 MODEL (LBS.)
104302 E2903-024S 104999 E2903-024SW 375 1275 120 3.1
24 5
104319 F2903-024S 105002 F2903-024SW 375 1275 208 1.8
104326 H2903-024S 105019 H2903-024SW 375 / 281 1275 / 955 240 / 208 1.6/1.4
104333 G2903-024S 105026 G2903-024SW 375 / 281 1275 / 955 277 / 240 1.6/1.2
104340 E2905-028S 105033 E2905-028SW 500 1706 120 4.2
28 6
104357 F2905-028S 105040 F2905-028SW 500 1706 208 2.4
104364 H2905-028S 105057 H2905-028SW 500 / 375 1706 / 1275 240 / 208 2.1/1.8
104371 G2905-028S 105064 G2905-028SW 500 / 375 1706 / 1275 277 / 240 1.8/1.6
104388 E2906-036S 105071 E2906-036SW 600 2040 120 5
36 7
104395 F2906-036S 105088 F2906-036SW 600 2040 208 2.9
104401 H2906-036S 105095 H2906-036SW 600 / 450 2040 / 1530 240 / 208 2.5/2.2
104418 G2906-036S 105101 G2906-036SW 600 / 450 2040 / 1530 277 / 240 2.2/1.9
104425 E2907-040S 105118 E2907-040SW 750 2550 120 6.3
40 8
104432 F2907-040S 105125 F2907-040SW 750 2550 208 3.6
104449 H2907-040S 105132 H2907-040SW 750 / 563 2550 / 1914 240 / 208 3.1/2.7
104456 G2907-040S 105149 G2907-040SW 750 / 563 2550 / 1914 277 / 240 2.7.2.6
104463 E2910-048S 105156 E2910-048SW 1000 3413 120 8.3
48 10
104470 F2910-048S 105163 F2910-048SW 1000 3413 208 4.8
104487 H2910-048S 105170 H2910-048SW 1000 / 750 3413 / 2550 240 / 208 4.2/3.6
104494 G2910-048S 105187 G2910-048SW 1000 / 750 3413 / 2550 277 / 240 3.6/3.1
104500 G2907-048S 105194 G2907-048SW 750 2550 277 3.4
104517 E2912-060S 105200 E2912-060SW 1250 4250 120 10.4
60 12
103008 F2912-060S 105217 F2912-060SW 1250 4250 208 6
103015 H2912-060S 105224 H2912-060SW 1250 / 938 4250 / 3189 240 / 208 5.2/4.5
103022 G2912-060S 105231 G2912-060SW 1250 / 938 4250 / 3189 277 / 240 4.5/3.9
103039 G2909-060S 105248 G2909-060SW 938 3189 277 3.4
103046 E2915-072S 105255 E2915-072SW 1500 5100 120 12.5
72 14
103053 F2915-072S 105262 F2915-072SW 1500 5100 208 7.2
103060 H2915-072S 105279 H2915-072SW 1500 / 1125 5100 / 3825 240 / 208 6.3/4.7
103077 G2915-072S 105286 G2915-072SW 1500 / 1125 5100 / 3825 277 / 240 5.4/4.7
103084 G2911-072S 105293 G2911-072SW 1125 3825 277 4.1
103091 F2917-084S 105309 F2917-084SW 1750 5950 208 8.4
84 16
103107 H2917-084S 105316 H2917-084SW 1750 / 1313 5950 / 4464 240 / 208 7.3/6.3
103114 G2917-084S 105323 G2917-084SW 1750 / 1313 5950 / 4464 277 / 240 6.3/5.5
103121 G2913-084S 105330 G2913-084SW 1313 4464 277 4.7
103138 F2920-096S 105347 F2920-096SW 2000 6826 208 9.6
96 18
103145 H2920-096S 105354 H2920-096SW 2000 / 1500 6826 / 5100 240 / 208 8.3/7.2
103152 G2920-096S 105361 G2920-096SW 2000 / 1500 6826 / 5100 277 / 240 7.2/6.3
103169 G2915-096S 105378 G2915-096SW 1500 5100 277 5.4
103213 F2925-120S 105422 F2925-120SW 2500 8532 208 12
120 22
103220 H2925-120S 105439 H2925-120SW 2500 / 1875 8532 / 6375 240 / 208 10.4/9.0
103237 G2925-120S 105446 G2925-120SW 2500 / 1875 8532 / 6375 277 / 240 9.0/7.8
103244 G2918-120S 105453 G2918-120SW 1875 6375 277 6.8
54
2900C Series Electric Baseboard - Heavy Duty Commercial Convection Heater
Features
Standard Models
Manufactured in U.S.A.
• Bankers bronze with stainless steel heating element and Aluminum ns.
• Powder coated 22 gauge steel front with 20 gauge junction boxes located on each
end of the heater - junction boxes contain quick connect cable clamps and 6”
ground lead wires.
• Standard inlet and outlet wire guards.
• Over-temperature thermal limit extends entire heated length of unit.
• A full length wireway provided along the back of the heater.
• Heater can be mounted to the wall by using the key hole knockouts every 4” at
the back of the heater.
• Optional In-Built thermostats eld installed in the junction box.
• HEIGHT: 6” DEPTH: 2-1/2”
International Models
UPC#
686334
BRONZE
MODEL WATTS BTU’s VOLTS AMPS HEATER
LENGTH (IN)
WEIGHT
(LBS)
103831 E2903-024C 375 1275 120 3.1
24 5
103848 F2903-024C 375 1275 208 1.8
103855 H2903-024C 375 / 281 1275 / 955 240 / 208 1.6 / 1.4
103862 G2903-024C 375 / 281 1275 / 955 277 / 240 1.6 / 1.2
103879 E2905-028C 500 1706 120 4.2
28 6
103886 F2905-028C 500 1706 208 2.4
103893 H2905-028C 500 / 375 1706 / 1275 240 / 208 2.1 / 1.8
103909 G2905-028C 500 / 375 1706 / 1275 277 / 240 1.8 / 1.6
103916 E2906-036C 600 2040 120 5.0
36 7
103923 F2906-036C 600 2040 208 2.9
103930 H2906-036C 600 / 450 2040 / 1530 240 / 208 2.5 / 2.2
103947 G2906-036C 600 / 450 2040 / 1530 277 / 240 2.2 / 1.9
103954 E2907-040C 750 2550 120 6.3
40 8
103961 F2907-040C 750 2550 208 3.6
103978 H2907-040C 750 / 563 2550 / 1914 240 / 208 3.1 / 2.7
103985 G2907-040C 750 / 563 2550 / 1914 277 / 240 2.7 / 2.6
103992 E2910-048C 1000 3413 120 8.3
48 10
104005 F2910-048C 1000 3413 208 4.8
104012 H2910-048C 1000 / 750 3413 / 2550 240 / 208 4.2 / 3.6
104029 G2910-048C 1000 / 750 3413 / 2550 277 / 240 3.6 / 3.1
104036 G2907-048C 750 2550 277 3.4
104043 E2912-060C 1250 4250 120 10.4
60 12
104050 F2912-060C 1250 4250 208 6.0
104067 H2912-060C 1250 / 938 4250 / 3189 240 / 208 5.2 / 4.5
104074 G2912-060C 1250 / 938 4250 / 3189 277 / 240 4.5 / 3.9
104081 G2909-060C 938 3189 277 3.4
104098 E2915-072C 1500 5100 120 12.5
72 14
104104 F2915-072C 1500 5100 208 7.2
104111 H2915-072C 1500 / 1125 5100 / 3825 240 / 208 6.3 / 4.7
104128 G2915-072C 1500 / 1125 5100 / 3825 277 / 240 5.4 / 4.7
104135 G2911-072C 1125 3825 277 4.1
104142 F2917-084C 1750 5950 208 8.4
84 16
104159 H2917-084C 1750 / 1313 5950 / 4464 240 / 208 7.3 / 6.3
104166 G2917-084C 1750 / 1313 5950 / 4464 277 / 240 6.3 / 5.5
104173 G2913-084C 1313 4464 277 4.7
104180 F2920-096C 2000 6826 208 9.6
96 18
104197 H2920-096C 2000 / 1500 6826 / 5100 240 / 208 8.3 / 7.2
104203 G2920-096C 2000 / 1500 6826 / 5100 277 / 240 7.2 / 6.3
104210 G2915-096C 1500 5100 277 5.4
104265 F2925-120C 2500 8532 208 12.0
120 22
104272 H2925-120C 2500 / 1875 8532 / 6375 240 / 208 10.4 / 9.0
104289 G2925-120C 2500 / 1875 8532 / 6375 277 / 240 9.0 / 7.8
104296 G2918-120C 1875 6375 277 6.8
UPC#
686334
BRONZE
MODEL WATTS BTU’s VOLTS AMPS HEATER
LENGTH (IN)
WEIGHT
(LBS)
118057 M2903-024CI 375 1275 220 1.7 24 5
118064 H2903-024CI 240 240
118071 M2905-028CI 500 1706 220 2.3 28 6
118088 H2905-028CI 240 2.1
118095 M2906-036CI 600 2040 220 2.7 36 7
118101 H2906-036C 240 2.5
118118 M2907-040CI 750 2550 220 3.4 40 8
118125 H2907-040C 240 3.1
118132 M2910-048CI 1000 3413 220 4.6 48 10
118149 H2910-048CI 240 4.2
118156 M2912-060CI 1250 4250 220 5.7 60 12
118163 H2912-060C 240 5.2
118170 M2915-072CI 1500 5100 220 6.8 72 14
118187 H2915-072CI 240 6.3
118194 M2917-084CI 1750 5950 220 8.0 84 16
118200 H2917-084CI 240 7.3
118217 M2920-096CI 2000 6826 220 9.1 96 18
118224 H2920-096CI 240 8.3
118231 M2925-120CI 2500 8532 220 11.4 120 22
118248 H2925-120CI 240 10.4
55
Electric Baseboard - Accessories
Blank Sections
Optional Wireway Covers
In-Built Thermostat Kits- With Two Cover Plates
Field Installed Accessories
**Not for use with 24A06G-1 relay.
UPC
686334 MODEL
BASEBOARD
LENGTH
(in.)
COVER
LENGTH
(in.)
WEIGHT
(LBS)
105705 WWA01 24 20 1
105712 WWA02 28 24 1.5
105729 WWA03 36 32 2
105736 WWA04 40 36 2.5
105743 WWA05 48 44 3
105750 WWA06 60 56 4
105767 WWA07 72 68 5
105774 WWA08 84 80 6
105781 WWA09 96 92 7
105798 WWA00 120 116 8
LENGTH IVORY WHITE BANKERS BRONZE WEIGHT
(LBS)
UPC MODEL UPC MODEL UPC MODEL
24” 105804 BBS024A 105903 BBS024AW 106009 BBS024C 5
28” 105811 BBS028A 105910 BBS028AW 106016 BBS028C 5 1/2
36” 105828 BBS036A 105927 BBS036AW 106023 BBS036C 6
40” 105835 BBS040A 105934 BBS040AW 106030 BBS040C 7
48” 105842 BBS048A 105941 BBS048AW 106047 BBS048C 8
60” 105859 BBS060A 105958 BBS060AW 106054 BBS060C 10
72” 105866 BBS072A 105965 BBS072AW 106061 BBS072C 12
84” 105873 BBS084A 105972 BBS084AW 106078 BBS084C 15
96” 105880 BBS096A 105989 BBS096AW 106085 BBS096C 17
120” 105897 BBS120A 105996 BBS120AW 106092 BBS120C 20
IVORY & WHITE
DESCRIPTION WEIGHT
(LBS)
UPC 686334 MODEL
NUMBER
105460 TBS SPST-In-Built 22A @ 120-240V 18A @ 277V
1/2 lbs.
502702 TBS-TP SPST-In-Built 22A @ 120-240V 18A @ 277V Tamperproof
105477 TBD DPST-In-Built 22A @ 120-240V 18A @ 277V
1/2 lbs.
502719 TBD-TP DPST-In-Built 22A @ 120-240V 18A @ 277V Tamperproof
DESCRIPTION
IVORY WHITE BANKERS BRONE WEIGHT
(LBS)
UPC 686334 MODEL UPC 686334 MODEL UPC 686334 MODEL
Disconnect Switch, 20
Amp, 120-277V 106108 DS 106115 DSW 106122 DSB
1 lb.
Corner Sections 105491 CS 105507 CSW 105514 CSB
1” Joiner Kits 105521 JK 105538 JKW 105545 JKB 1/4 lb.
6” Blank Relay Section
(Relay Not Included)** 105552 LVRS 105569 LVRSW 105576 LVRSB 1 1/2 lbs.
Receptacle Section
(Baseboard Mounted)
15 Amp 120 VAC
105583 BDR115 105590 BDR115W 105606 BDR115B 1/4 lb.
Receptacle Section
(Mounted in 6” Blank)
15 Amp 120 VAC
105613 DR115 105620 DR115W 105637 DR115B
2 lbs.
Transfer Switch
(Mounted in 6” Blank)
16 Amp 120 VAC
105644 SR120 105651 SR120W 105668 SR120B
Transfer Switch
(Mounted in 6” Blank)
16 Amp 240 VAC
105675 SR220 105682 SR220W 105699 SR220B
56
HOW TO DESIGNATE A MODEL:
E 91 96 250 ITS PD
Element Volts
E = 120
F = 208
G = 277
H = 240
Model Series
91
Heater Length
(inches)
28, 36, 48, 60,
72, 84, 96, 108,
or 120
Watts Per Foot
100, 125, 150,
165, 187, 200,
or 250
Control Options
Refer to Pg. 60
Factory Installed
Accessories
PD = Pedestal
DR = Receptacle
WM = Screen
Features
9100 Series - Radius Front Draft Barrier Heater
Product Description
Factory Installed Accessories
Field Installed Accessories
ETL listed up to 250
Watts / foot for industrial,
commercial, or residential
applications.
• Standard colors, white or ivory.
• “UNI-LOCK” construction allows snap-t, 2 piece
installation.
• Units can be controlled by optional In-Built thermostat
or can be constructed with relays and / or transformers
for low voltage or line voltage wall thermostats
• Thermal protection by full length manual reset linear limits
• Optional duplex receptacle section
• Wiring junction boxes on each end of the unit
• Custom colors and nishes available (consult factory)
• Limited by max Amp draw of 25 Amps (with no controls).
• Additional charges may be incurred if changes are made
after production has begun - consult factory.
Standard Models
Manufactured in U.S.A.
TECHNICAL INFORMATION
Height 4 1/2”
Depth 3 1/8”
Length 28” to 120” in 1’ increments
Cabinet Material Material
Gauge
Aluminum
14
Optional Controls That Can
Be Built Into Unit
Thermostat and Disconnect Switch
(Control Section Required for Relays)
TECHNICAL INFORMATION
Air Intake Bottom
Air Discharge Top
Min Mounting Height 3”
Max Watts / Foot 250
Max Allowable Amps 25 Amps (20 Amps with disconnect)
Voltage / Phase 120V/208V/240V/277V Single Phase
Note: All models are suitable for International use
MODEL UNIT
LENGTH
HEATER
9128 28”
9136 36”
9148 48”
9160 60”
9172 72”
9184 84”
9196 96”
91108 108”
91120 120”
SUFFIX DESCRIPTION
DR Duplex Receptacle in 4” Extended Enclosure
(not available with 120” heater)
PD
28” through 60” - 2 Required
72” through 96” - 3 Required
108” through 120” - 4 Required
WM 1/4” wire mesh under grill
MODEL DESCRIPTION
9100IC Inside Corner Section 90° or 135°
9100OC Outside Corner Section 90° or 135°
9100EC Right or Left End Cap
MODEL UNIT
LENGTH
BLANK SECTION
91BS012 12”
91BS024 24”
91BS036 36”
91BS048 48”
91BS060 60”
91BS072 72”
91BS084 84”
91BS096 96”
91BS108 108”
91BS120 120”
57
6.0”
6.0”
Ø .395 (TYP)
3-1/8"
1-9/16"
3"
3-1/8"
4-1/2" 1-9/16"
3" MINIMUM
FINISHED FLOOR
15/16"
WALL MOUNT
PEDESTAL MOUNT
2-1/16"
2-7/16"
TYP
PEDESTAL
BASE
3-1/16”
1-1/2"
1-1/8"
1-9/16"
BACK VIEW
OUTSIDE CORNER
SECTION
INSIDE CORNER
SECTION
9100 Series - Radius Front Draft Barrier Heater
Product Specications
Product Dimensions
CABINET
9100 Series shall be constructed of 14 gauge extruded 6063 Aluminum heat treated to T5 hardness. The
uni-lock construction shall allow easy installation and access to back plate for wiring. The snap-t front
cover makes installation and service very simple. Custom factory enclosures to 1/16 inch increments are
built for exact wall to wall t up to 10 foot enclosure lengths. The 14 gauge back plate will have electrical
knockouts for incoming power on each end adjacent to junction box. Pedestal mounted units will have
incoming power connection through the pedestal on bottom of unit and will have smooth back for optional
nished back. The die punched front cover will have no screw heads or fasteners.
ELEMENTS
High mass sheathed element construction with Nickel-Chromium resistance wire embedded in compacted
efcient die-electric to ensure proper heat transfer. Aluminum ns mechanically bonded to stainless steel
tube allows for increased surface area and even heat transfer.
LIMIT CONTROLS
Manual reset hydraulic thermal overload covers full length of heating element and shuts down heater when
safe operating temperatures are exceeded.
WIRING
Wiring shall be in either end of the enclosure. Wiring can be in the junction box or optional control section
if additional controls are needed. Pedestal mounted units shall have 1-1/4” hole through the pedestal and in
the bottom of the enclosure for incoming power wiring. All heaters have a factory supplied built in raceway
for wiring from either end of the heater or for wiring of continuous heater connections.
CONTROLS
Optional controls include single or double pole thermostat and disconnect switch that are factory wired
in enclosed junction box on each end of heater enclosure. Relay, transformer relay and duplex receptacle
options shall be mounted in extended length control section. Control section will add to heater enclosure
length. The control section for the duplex receptacle will add 4” to enclosure length. The control section for
other optional components or combinations of components will have two options (6” or 12”) depending on
controls required.
APPLICATION
The 9100 series is ETL listed for commercial, industrial or residential applications on all units up to 250
Watts per foot.
58
Field Installed Accessories
HOW TO DESIGNATE A MODEL:
E 93 96 B 250 ITS PD
Heater Length
(inches)
28, 36, 48, 60,
72, 84, 96, 108,
or 120
Inlet
B = Bottom
F = Front
Element Volts
E = 120
F = 208
H = 240
G = 277
L = 347
P1 = 480
U1 = 600
Single Phase
J = 208
K = 240
P3 = 480
U3 = 600
Three Phase
Watts Per Foot
Per Element
100, 125, 150,
165, 187, 200,
or 250
Control Options
Refer to Pg. 60
of TPI Heat
catalog.
Factory Installed
Accessories
PD = Pedestal
DR = Receptacle
WM = Screen
Model Series
93
9300 Series - Radius Front Draft Barrier Heater
• Leed and green compliance, 1 and 3 phase applications
• Industrial or commercial applications
• Standard color: Bankers Bronze (powder coated)
• Also available in other standard TPI colors and custom
colors for an additional charge
• Uni-lock construction for snap t 2 piece installation
• Temperature control can be in-built or wall mounted
• Thermal protection by full length manual reset linear limits
• Optional accessories include: duplex receptacle, and inside
or outside corner sections for wall to wall custom t.
• Additional charges may be incurred if changes are made
after production has begun - consult factory.
Features
ETL listed up to 750 Watts
/ foot for industrial or
commercial applications.
Manufactured in U.S.A.
Note: All models are suitable for International use
Product Description
Factory Installed Accessories
Standard Models
TECHNICAL INFORMATION
Height 7.5”
Depth 6.15”
Length 28” to 120” in 1’ increments
Cabinet Material
Material Gauge
Aluminum
12
Optional Controls That
Can Be Built Into Unit
Thermostat, Disconnect Switch, Transformer
(Control Section Required for Relays)
TECHNICAL INFORMATION
Air Intake Bottom / Front
Air Discharge Top
Min Mounting Height 3” for bottom intake / 0” for front intake
Max Watts / Foot 750
Max Allowable Amps 25 without relay, 40 with relay
Voltage / Phase 120V/208V/240V/277V/347V,480V,600V Single Phase
208V,240V,480V,600V Three Phase
Note: If using line voltage thermostat on 1 phase heaters, you
cannot exceed 25 Amps due to Amp rating of thermostat. 347,
480, and 600V can use 30 Amps with in-built thermostat.
Note:
480V single phase units minimum 36” heated length; 600V single phase units minimum 48” heated length
347-480-600 single phase and all three phase units are built with low voltage option factory installed
MODEL UNIT LENGTH
Heater
9328 28”
9336 36”
9348 48”
9360 60”
9372 72”
9384 84”
9396 96”
93108 108”
93120 120”
SUFFIX DESCRIPTION
DR Duplex Receptacle in 4” Extended Enclosure
(not available with 120” heater)
PD
28” through 60” - 2 Required
72” through 96” - 3 Required
108” through 120” - 4 Required
WM 1/4” wire mesh under grill
IDS 30 Amp/240V Disconnect Switch
40 Amp/600V Disconnect Switch
MODEL DESCRIPTION
9300IC Inside Corner Section 90° or 135°
9300OC Outside Corner Section 90° or 135°
9300EC Right or Left End Cap
MODEL UNIT LENGTH
Blank Section
93BS012 12”
93BS024 24”
93BS036 36”
93BS048 48”
93BS060 60”
93BS072 72”
93BS084 84”
93BS096 96”
93BS108 108”
93BS120 120”
59
Ø .395 (TYP)
3
1
16
"
TYP
PEDESTAL
BASE
3"
7.500
6.15
2
15
16
7.500
6.15
3" MINIMUM
FINISHED FLOOR
2
716
"
"
12.0
12.0
Ø .395 (TYP)
3
1
16
"
TYP
PEDESTAL
BASE
3"
7.500
6.15
2
15
16
7.500
6.15
3" MINIMUM
FINISHED FLOOR
2
716
"
"
12.0
12.0
Ø .395 (TYP)
3
1
16
"
TYP
PEDESTAL
BASE
3"
7.500
6.15
2
15
16
7.500
6.15
3" MINIMUM
FINISHED FLOOR
2
716
"
"
12.0
12.0
9300 Series - Radius Front Draft Barrier Heater
Product Dimensions
CABINET
9300 Series shall be constructed of 12 gauge extruded 6063 Aluminum heat treated to T5 hardness. The
uni-lock construction shall allow easy installation and access to back plate for wiring. The snap-t front
cover makes installation and service very simple. Custom factory enclosures to 1/16 inch increments are
built for exact wall to wall t up to 10 foot enclosure lengths. The 12 gauge back plate will have electrical
knockouts for incoming power on each end adjacent to junction box. Pedestal mounted units will have
incoming power connection through the pedestal on bottom of unit and will have smooth back for optional
nished back. The die punched front cover will have no screw heads or fasteners.
ELEMENTS
High mass sheathed element construction with Nickel-Chromium resistance wire embedded in compacted
efcient die-electric to ensure proper heat transfer. Aluminum ns mechanically bonded to stainless steel
tube allows for increased surface area and even heat transfer.
LIMIT CONTROLS
Manual reset hydraulic thermal overload covers full length of heating element and shuts down heater when
safe operating temperatures are exceeded.
WIRING
Wiring shall be in either end of the enclosure. Wiring can be in the junction box or optional control section
if additional controls are needed. Pedestal mounted units shall have 1-1/4” hole through the pedestal and in
the bottom of the enclosure for incoming power wiring. All heaters have a factory supplied built in raceway
for wiring from either end of the heater or for wiring of continuous heater connections.
CONTROLS
Optional controls include single or double pole thermostat and disconnect switch that are factory wired
in enclosed junction box on each end of heater enclosure. Relay, transformer relay and duplex receptacle
options shall be mounted in extended length control section. Control section will add to heater enclosure
length. The control section for the duplex receptacle will add 4” to enclosure length. The control section for
other optional components or combinations of components will have two options (6” or 12”) depending on
controls required.
APPLICATION
The 9300 series is ETL listed for commercial or industrial applications on all units up to 750 Watts per foot
on single phase units. 3 Phase units have a minimum of 300 Watts per foot.
Product Specications
INSIDE CORNER
SECTION
OUTSIDE CORNER
SECTION
60
Draft Barrier Heaters - General Product Information
All Draft Barrier Heaters, unless otherwise noted, are build to order items. Consult factory for lead times.
Additional charges may be incurred if changes are made after production has begun - consult factory.
Electric Draft Barrier Features
How To Designate A Model NOTE:
• Extended enclosures and
Blank Sections are NOT
punched. When a Control
Section is specied, ALWAYS
allow for an extended
enclosure to compensate for
the 6” or 12” length of the
Section required.
• Note on order when nished
backs are required and add
list adder to model list.
• Total heater amperage must
not exceed the 25-Amp rating
of the high temperature limit
at any voltage or wattage.
This applies to all Sill Line
Model Series.
*Units with Extended Enclosures may require more Pedestals than standard length, must verify length of heater after extended enclosures for
total amount of pedestals. NOTE: All bottom inlet units must be mounted a minimum of 3 inches above nished oor.
Dual element models DBCT/DBCF and ASHDB may have any combination of elements. All elements are single phase.
Custom wattages are available within certain parameters, consult factory for more information.
Voltage & Wattage Specication
Control Options
• “UNI-LOCK” construction allows snap-t, 2 piece installation
• Heavy Gauge Aluminum Extruded enclosures, 6063 heat
treated to T-5 hardness
a. DBT/DBF & RDBT-PD-12 gauge front & back
b. DBCT/DBCF- 10 gauge Front & Back
c. CB-14 gauge Front & Back
• ASHDB Series is 16 gauge Steel Front with 18 Steel gauge back
• 1/4” pencil proof discharge louvers
• Thermal protection by full length linear limits
• Multiple heaters, factory wired on same back plate,
available in up to 10’ lengths
• Totally enclosed junction boxes
• Custom colors and nishes available (See Chart )
• Enclosures available for hydronic heating coils
(consult factory for more information )
Digit (Example) MODEL NUMBER DESIGNATION - “ASI” DRAFT BARRIER
Digit 1= DBT Series Model Number ( DBT/DBF, CB, Etc.)
Digit 2= PD
Use if Pedestals are Required*
2’ to 5’ Heaters require 2 pedestals
6’ to 8’ Heaters require 3 pedestals
9’ & 10’ Heaters require 4 pedestals
Digit 3= 4
Heated Length of Heater
(for extended enclosure, specify amount of required enclosure on
order write up, IE: 4’ Heated length w/ 2’6” of extended enclosure)
Digit 4= 250 Wattage per Linear foot ( may not exceed allowable wattages
on specic models, refer to catalogue page to verify maximum WPF)
Digit 5= ITS (etc) Control Options ; Refer to List Price chart for available options
( Verify on each model which options may be factory installed )
Completed example: DBT-PD-4250-ITS
Voltage Standard Wattages Per Foot Heater Lengths
120-277 125,165,187,200,250*,333*,375* 2’ through 10’
Note: If using line voltage thermostat on single phase heaters you cannot exceed 25 Amps due to Amp rating
of thermostat. 347, 480, and 600V models can use up to 30 Amps with in-built thermostat.
CUSTOM PAINT COLORS
Durable Powder Coat Paint Finish
Bankers Bronze - standard color
Eggshell White
Black
Gray
Beige
Bronze Anodized*
*simulated powder
coat nish
Special Colors (5 lb. Increment)
ANODIZING*
* 204R1 Clear; 313R1 Bronze and
Black
Sufx Designation Description
CS 6 6” control section / will contain up to 2 control options
CS 12 12” control section / will contain up to 3 control options
ITS Single Pole, 25 Amp integral thermostat, 120,208,240 & 277 Volts
ITD Double Pole, 25 Amp integral thermostat, 120,208,240 & 277 Volts
IDS Double Pole Disconnect, 20 Amp, 120, 208, 240 & 277 Volts
IDS 30 30 Amp disconnect (9300 Series)
IDS 40 40 Amp disconnect (9300 Series)
LVTR Low voltage controls (trans & relay)
PR 120-277/24
Power Relay, 18 Amp tested, Must specify coil voltage
Single Pole
PR 120-277/120
PR 120-277/240
ATR*
Single Pole, rated 25 Amps, 120 to 240 Volts,
Contacts rated up to 277 Volts (must specify )
Coils are 24 Volt; 24 Volt transformer
* Not suitable for International use
Note: Please refer to each model to verify how many controls may be integrally mounted, Control sections will add length
to the heater. Must use control section with PR 240/24, PR 208/24, 208/208 and ATR
61
DBF / DBT Series
NOTE: DBF/DBT Series will permit a Thermostat mounted
on one side and a Disconnect on the other side, more or
other controls require a 6” or 12” control section. Typically,
thermostats are mounted on left side of heater. Control Section
will add to length of heater.
DBCT / DBCF Series
NOTE: DBCT/DBCF Series will permit a Thermostat
mounted on one side and Disconnect on the other side, more
or other controls require a 6” or 12” control section. Typically,
Thermostats are mounted on left side of heater. Control Section
will add to the length of heater.
Cabinet Dimensions: 3-1/2” x 6” x 10’ Maximum Length
Not suitable for residential applications above 150 Watts
per foot. Built to order: consult factory for lead time.
DBF Floor Mount
Model-250 WPF Max.
DBT Wall Mount
Model-300 WPF Max.
DBCT Wall Mount
Model-750 WPF Max.
DBCF Floor Mount
Model-600 WPF Max.
Cabinet Dimensions: 5” x 7” x 10’ Maximum Length
Not suitable for residential applications. Built to order:
consult factory for lead time.
Manufactured in U.S.A.Manufactured in U.S.A.
MODEL LENGTH
Color Availablility
(heater & nished
back)
DBF-2/DBT-2 2’
Clear Anodized
Color Anodized
Painted Bronze
DBF-3/DBT-3 3’
DBF-4/DBT-4 4’
DBF-5/DBT-5 5’
DBF-6/DBT-6 6’
DBF-7/DBT-7 7’
DBF-8/DBT-8 8’
DBF-9/DBT-9 9’
DBF-10/DBT-10 10’
Extended Enclosure
(no color on nished back)
Blank Sections
DBF/DBT-100BS 1’
DBF/DBT-200BS 2’
DBF/DBT-300BS 3’
DBF/DBT-400BS 4’
DBF/DBT-500BS 5’
DBF/DBT-600BS 6’
DBF/DBT-700BS 7’
DBF/DBT-800BS 8’
DBF/DBT-900BS 9’
DBF/DBT-1000BS 10’
Accessories Color Availability
DBF/DBT IC / Inside Corner Section
Clear Anodized
Color Anodized
Painted Bronze
90 - 180 Degrees
DBF/DBT OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
DBF/DBT ECR / Right Hand End Cap
DBF/DBT ECL / Left Hand End Cap
DBF/DBT IECR / Inside Fitting Right End Cap
DBF/DBT IECL / Inside Fitting Left End Cap
DBF/DBT WT / 2”- 6” Wall Trim
DBF/DBT SP / 1 1/2” Splice Plate
DBF/DBT MF / Mullion Front up to 1’
DBF/DBT IF / Inside Filler up to 1’
3/4” Conduit Raceway (standard is 1/2”)
Mesh / 1/4” Wire Mesh under Grill
Pedestals - specify 2” or 3”
See Chart for required amount per Heater
MODEL / LENGTH WATTS/FT. Color Availability
(heater & nished back)
DBCT-2/DBCF-2 to 250
Clear Anodized
Color Anodized
Painted Bronze
2’ 251-750
DBCT-3/DBCF-3 to 250
3’ 251-750
DBCT-4/DBCF-4 to 250
4’ 251-750
DBCT-5/DBCF-5 to 250
5’ 251-750
DBCT-6/DBCF-6 to 250
6’ 251-750
DBCT-7/DBCF-7 to 250
7’ 251-750
DBCT-8/DBCF-8 to 250
8’ 251-750
DBCT-9/DBCF-9 to 250
9’ 251-750
DBCT-10/DBCF-10 to 250
10’ 251-750
Extended Enclosure
(no color on nished back)
Blank Sections
DBCT/DBCF-100BS 1’
DBCT/DBCF-200BS 2’
DBCT/DBCF-300BS 3’
DBCT/DBCF-400BS 4’
DBCT/DBCF-500BS 5’
DBCT/DBCF-600BS 6’
DBCT/DBCF-700BS 7’
DBCT/DBCF-800BS 8’
DBCT/DBCF-900BS 9’
DBCT/DBCF-1000BS 10’
Accessories Color Availability
DBCT/DBCF IC / Inside Corner Section
Clear Anodized
Color Anodized
Painted Bronze
90 - 180 Degrees
DBCT/DBCF OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
DBCT/DBCF ECR / Right End Plate
DBCT/DBCF ECL / Left End Plate
DBCT/DBCF IECR/ Right End Plate (inside t)
DBCT/DBCF IECL/ Left End plate (inside t)
DBCT/DBCF WT / Wall Trim 2” - 6”
DBCT/DBCF SP / 1 1/2” Splice Plate
DBCT/DBCF IF / Inside Filler (up to 1’)
3/4” Conduit Raceway (standard is 1/2”)
Mesh / 1/4” Wire Mesh under Grill
Pedestals - specify 2” or 3”
See Chart for required amount per Heater
62
DBTS Series Draft Barrier Heaters
Features
• Bottom air intake.
• Maximum watts per foot: 300.
• Dimensions: Depth 2-5/8'” x Height 4" Length 2’ to 10'.
• 14 gauge Aluminum housing.
• Voltages: 120V / 208V / 240V / 277V - 1 Phase
• No controls can be added without adding a control section and
extended enclosure.
Standard Models
Manufactured in U.S.A.
Accessories
Not suitable for residential applications. 150 watts
per foot maximum. Built to order: consult factory
for lead time.
MODEL LENGTH
HEATER
DBTS-2 2’
DBTS-3 3’
DBTS-4 4’
DBTS-5 5’
DBTS-6 6’
DBTS-7 7’
DBTS-8 8’
DBTS-9 9’
DBTS-10 10’
MODEL DESCRIPTION
DBTS IC Inside Corner Section 90° - 180°
DBTS OC Outside Corner Section 180° - 270° - 6” longest side
DBTS ECR Right Hand End Cap
DBTS ECL Left Hand End Cap
DBTS IECR Inside Fitting Right End Cap
DBTS IECL Inside Fitting Left End Cap
DBTS WT Wall Trim 2” - 6”
DBTS SP Splice Plate 1 1/2”
DBTS MF Mullion Front up to 1’
Note on order
1/2” Conduit Raceway
Mesh 1/4” Wire Mesh under grill
Pedestals - specify 2” or 3”
MODEL LENGTH
BLANK
SECTION
DBTS-100BS 1’
DBTS-200BS 2’
DBTS-300BS 3’
DBTS-400BS 4’
DBTS-500BS 5’
DBTS-600BS 6’
DBTS-700BS 7’
DBTS-800BS 8’
DBTS-900BS 9’
DBTS-1000BS 10’
63
RDBT Series ASHDB Series
Cabinet Dimensions: 7” x 6” x 10’
Maximum Length
Not suitable for residential
applications. 300 Watts Per Foot
Maximum. Pedestals included with
unit. Rounded enclosure with at
top discharge. Special Build: consult
factory for lead time.
NOTE: RDBT-PD Series will permit a Thermostat mounted on one side and
a Disconnect on the other side. More or other controls require a 6” or 12”
control section. Typically, Thermostats are mounted on the left side of heater.
Control Sections will add to length of heater.
Cabinet Dimensions: 5-1/2” x 8”
thru 20” x 10’ Maximum Length.
Cannot be Anodized
Not suitable for residential applications.
500 Watts per foot maximum. 16 gauge
Steel enclosure, 18 gauge backplate.
Heights may vary from 8” up to 20.”
Bottom Intake / Top Discharge. Special
build - consult factory for lead time.
NOTE: ASHDB Series will permit a Thermostat mounted on one side and
a Disconnect on the other side, more or other controls require a 6” or 12”
control section. Typically, Thermostats are mounted on left side of heater.
Control Section will add to length of heater.
CB Series
NOTE: CB Series will
permit either a Thermostat
or a Disconnect on only
one side of the heater. More
or other controls require a
control section. Typically,
Thermostats are mounted
on the right side of heater.
Control Sections will add to
length of heater.
Cabinet Dimensions:
2-5/8” x 4-1/2” x 10’
Maximum Length
Not suitable for residential
applications. Bottom inlet
only. Built to order: consult
factory for lead time.
Manufactured in U.S.A.
Manufactured in U.S.A.
Manufactured in U.S.A.
MODEL LENGTH Color Availability
RDBT-PD-2 2’
Clear Anodized
Color Anodized
Painted Bronze
RDBT-PD-3 3’
RDBT-PD-4 4’
RDBT-PD-5 5’
RDBT-PD-6 6’
RDBT-PD-7 7’
RDBT-PD-8 8’
RDBT-PD-9 9’
RDBT-PD-10 10’
Extended Enclosure
Blank Sections
RDBT-PD-100BS 1’
RDBT-PD-200BS 2’
RDBT-PD-300BS 3’
RDBT-PD-400BS 4’
RDBT-PD-500BS 5’
RDBT-PD-600BS 6’
RDBT-PD-700BS 7’
RDBT-PD-800BS 8’
RDBT-PD-900BS 9’
RDBT-PD-1000BS 10’
Accessories Color Availability
RDBT-PDIC / Inside Corner Section
Clear Anodized
Color Anodized
Painted Bronze
90 - 180 Degrees
RDBT-PDOC / Outside Corner Section
180 - 270 Degrees - 6” longest side
RDBT-PDIECR/Inside Fitting Right End Cap
RDBT-PDIECL/Inside Fitting Left End Cap
3/4” Conduit Raceway (standard is 1/2”)
Mesh - 1/4” Wire Mesh under Grill
MODEL / LENGTH WATTS/FT. Color Availability
(heater & nished back)
ASHDB-2 to 250
Painted Bronze
2’ 251-500
ASHDB-3 to 250
3’ 251-500
ASHDB-4 to 250
4’ 251-500
ASHDB-5 to 250
5’ 251-500
ASHDB-6 to 250
6’ 251-500
ASHDB-7 to 250
7’ 251-500
ASHDB-8 to 250
8’ 251-500
ASHDB-9 to 250
9’ 251-500
ASHDB-10 to 250
10’ 251-500
Extended Enclosure
(no color on nished back)
Blank Sections
ASHDB-8/20-100BS 1’
ASHDB-8/20-200BS 2’
ASHDB-8/20-300BS 3’
ASHDB-8/20-400BS 4’
ASHDB-8/20-500BS 5’
ASHDB-8/20-600BS 6’
ASHDB-8/20-700BS 7’
ASHDB-8/20-800BS 8’
ASHDB-8/20-900BS 9’
ASHDB-8/20-1000BS 10’
Accessories Color Availability
ASHDB IC / Inside Corner Section
Painted Bronze
90 - 180 Degrees
ASHDB OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
ASHDB ECR / Right End Cap
ASHDB ECL / Left End Cap
ASHDB SP / 1 1/2” Splice Plate
ASHDB WT / 2” - 6” Wall Trim
3/4” Conduit Raceway ( standard is 1/2”)
Mesh / 1/4” Wire Mesh under Grill
Pedestals - Specify 2” or 3”
See Chart for required amount per Heater
Model Length Color (heater &
nished back)
CB-2 2’
Clear Anodized
Color Anodized
Painted Bronze
CB-3 3’
CB-4 4’
CB-5 5’
CB-6 6’
CB-7 7’
CB-8 8’
CB-9 9’
CB-10 10’
Extended Enclosure
(no color on nished back)
Blank Sections
CB-100BS 1’
CB-200BS 2’
CB-300BS 3’
CB-400BS 4’
CB-500BS 5’
CB-600BS 6’
CB-700BS 7’
CB-800BS 8’
CB-900BS 9’
CB-1000BS 10’
Accessories Color Availability
CB IC / Inside Corner Section
Clear Anodized
Color Anodized
Painted Bronze
90 - 180 Degrees
CB OC / Outside Corner Section
180 - 270 Degrees - 6” longest side
CB ECR / Right End Cap
CB ECL / Left End Cap
CB WT / Wall Trim 2” - 6”
CB SP / Splice Plate 1 1/2”
CB MF / Mullion Front up to 1’
1/2” Conduit Raceway
Mesh / 1/4” Wire Mesh under Grill
Pedestals - specify 2” or 3”
See Chart for required amount per Heater
64
MR Series Heavy Duty Metal Sheath Electric Infrared Heater
Heavy Duty Overhead Infrared Heaters for Indoor Spot Heating, Zone or Total Area
Heating Applications
Note: Some 3-Phase models can be eld converted to single phase operation.
MR-6/13 KW
MR-2/4 KW
MR Series Safety Note
Standard Models
Heavy Duty Metal Sheath Infrared Control Options
CONTROL FEATURES:
• (GF-SK-1) Positive “off” and built-in
“on/off” rocker switch illuminates “red”
during operation.
• Controls cannot be mounted directly on
unit. Must use 6” minimum threaded
conduit.
Manufactured in U.S.A.
Ground fault protection must be used. To avoid potential hazards use model GF-SK-1 ground fault sensing switch with these heaters.
This device is designed to provide a reliable way to quickly terminate power to the heaters in the event of a ground fault occurrence.
• High-Density radiant heat, with 60° symmetric
heat pattern.
• ETL Listed for suspended high-bay indoor
applications
• Rugged straight metal sheath elements installed,
great for high vibration areas.
• Gold anodized Aluminum housing for efcient,
long term reectivity & corrosion resistance.
• Terminal box with high-temp Silicone wire.
• Single or three phase wiring.
• ”L” brackets included for chain suspension, or
rigid mounting.
UPC#
686334 MODEL KW BTU’S VOLTS PHASE
AMPS WT.
(Lbs.)
Optional Wireguards
3-Ph 1-Ph UPC#
686334 MODEL
135177 MR-212-1 1.8* 6,143 120 1
N/A
15.0
9.0 449090 HDWG-2
135184 MR-220-1
2.0 6,826
208
1
9.6
135214 MR-224-1 240 8.5
135221 MR-227-1 277 7.2
135238 MR-248-1 480 4.2
135245 MR-257-1 600 3.3
135306 MR-420-1
4.5 15,359
208
1
21.6
15.0 449069 HDWG-4
135320 MR-424-1 240 18.8
135337 MR-427-1 277 16.3
135344 MR-448-1 480 9.5
135351 MR-457-1 600 7.5
135368 MR-620-3
6.0 20,478
208
3 or 1
17.0 29.0
27.0 449076 HDWG-6
135375 MR-624-3 240 14.5 25.0
135382 MR-627-3 277 N/A 21.7
135412 MR-648-3 480 7.5 13.0
135429 MR-657-3 600 5.8 10.0
135115 MR-1320-3
13.5 46,076
208 337.5 N/A
43.0 449083 HDWG-13
135122 MR-1324-3 240 33.0
135139 MR-1327-3 277
3 or 1
N/A 48.8
135153 MR-1348-3 480 17.0 29.0
135160 MR-1357-3 600 13.6
N/A
135252 MR-2720-3
27* 92,151
208
3
74.8
288.0
Crated 883047 HDWG-27
135269 MR-2724-3 240 64.8
135283 MR-2748-3 480 32.4
135290 MR-2757-3 600 26.7
UPC
686334 MODEL DESCRIPTION RATING
(VAC)
Dimensions (In) WT.
(lbs.)
Ht. Wd. Dp.
486026 GF-SK-1 Ground Fault
Sensing Switch
208V - 600V
50A 10.3 10.3 5.0 12
589376 DC-SK-1 Disconnect
Switch
120V - 600V
50A 5.0 6.0 4.0 5
65
MR Series Heavy Duty Metal Sheath Electric Infrared Heater
Note: The MR-27 Series includes (2) Terminal Box
Assemblies, located on each end of the heater, requiring
an electrical service to each end.
Housing:
.040 Gold anodized Aluminum housing for efficient,
long-term reflectivity and corrosion resistance. High-
density radiant heat. Housing is ETL Listed for indoor,
dry environment applications only.
Reflector:
60 degree symmetric heat pattern.
Elements:
Rugged straight metal sheath elements. .430” diameter
Incoloy 840 metal sheath. Nickel-Chrome alloy coiled
filament imbedded within a Magnesium Oxide insulating
powder and threaded end terminations. Available wattages
in 1800, 2000, and 4500 Watts per element. Available in
standard voltages from 120 to 600 Volts.
Controls:
Heavy Duty, Metal Sheath heaters are not manufactured
with any control device on the unit. All controls and
accessories should be specified as remote mounted.
Please consult the technical sales department of factory
for help in determining applicable controls. Please follow
installation instructions that accompany each heater.
Accessories:
Wire guards and power contactor panels.
MR-27 KW
Product Specications
Mounting Clearances & Recommended Mounting Height
MR Series Dimensions & Reector Pattern
60° Symmetric
NOTE: Take into account that the MR
Series is designed with a 60° symmetrical
reector heat pattern. The sizing chart can
assist you based upon your mounting height.
Sizing Chart
Manufactured in U.S.A.
Mounting Clearances Recommended Mounting Height
All MR Models
24” from ceiling
36” from vertical surface & from another heater
72” from face of heater to combustible surface
1.8 & 2.0 KW 8’ - 10’
4.5 KW 8’ - 12’
6.0 KW 10’ - 14’
13.5 KW 12’ - 16’
MR-27 Only 87” from face of heater to combustible surface 27.0 KW 15’ - 30’
DIMENSIONS (in.)
SERIES A B C
LENGTH WIDTH DEPTH
MR-2 28 9 7.25
MR-4 48.5 9 7.25
MR-6 30 19.88 7.5
MR-13 50.5 19.88 7.5
MR-27 96.75 28.25 14.88
Mounting
Height
Heater
Model Length Wide Coverage
(Sq. Ft.)
Watts / Sq.
Ft.
8’
MR-2 8 8 64 31.3
MR-4 9 8 72 62.5
10’
MR-2 11 10 110 18.2
MR-4 11 10 110 40.9
MR-6 12 10 120 50.0
12’
MR-4 12 11.5 138 32.6
MR-6 14 12 168 35.7
MR-13 15 13 195 69.2
14’
MR-6 16 14 224 26.8
MR-13 18 16 288 46.9
16’
MR-6 18 16 288 20.8
MR-13 21 18 378 35.7
MR-27 24 19 456 59.2
18’
MR-13 23 20 460 29.3
MR-27 28 20 560 48.2
20’ MR-27 28 23 644 41.9
24’ MR-27 33 27 891 30.3
30’ MR-27 41 32 1312 20.6
66 Overhead Infrared Heaters for Snow & Ice Control, Outdoor Spot Heating & All Indoor
Heating Applications
Product Dimensions
Mounting Clearances & Recommended Mounting Height
Mounting Clearances Recommended Mounting Height
2 & 3 Lamp
Models
3” from ceiling 30° Symmetric & A30° Asymmetric Reector -
Indoor 14’ - 30’
24” from vertical surface 60° Symmetric & A60° Asymmetric Reector -
Indoor 12’ - 18’
2 Lamp Models 72” from face of heater to combustible
surface
90° Symmetric Reector
- Indoor 8’ - 12’
3 Lamp Models 96” from face of heater to combustible
surface
30° Symmetric & A30° Asymmetric Reector -
Outdoor 8’ - 10’
TH & THSS Series Mul-T-Mount Electric Infrared Heater
Product Description
AVAILABLE IN 2 LAMP BROWN ENAMEL OR STAINLESS STEEL,
OR 3 LAMP STAINLESS STEEL.
New Feature:
In-Built surface mounting brackets
allows for xture adjustment up to
45° horizontal tilt.
0 to 45o tilt @
15o increments
In-built surface
mounting
brackets
attached to
the top wiring
channel.
Mul-T- Dimensions (in.)
Mount A B C D
Series Length Width Height Mtg. Ctr.
222 24" 15" 10-7/8" 23-1/2"
342 33" 15" 10-7/8" 32-1/2"
462 46" 15" 10-7/8" 45-1/2"
223 24" 21-1/2" 10-7/8" 23-1/2"
343 33" 21-1/2" 10-7/8" 34"
463 46" 21-1/2" 10-7/8" 45-1/2"
Manufactured in U.S.A.
• Listed for suspended, totally exposed (outdoor), high-bay (indoor)
comfort heating and exterior snow & ice control applications.
• Listed for recessed applications.
• 20 gauge painted steel or stainless steel housings.
• Gold anodized Aluminum reectors & end caps.
• 50% higher Watt densities for 3-element units.
• 2-Lamp wiring, single phase.
• 3-Lamp wiring, three or single phase.
• Stainless steel models have non-corrosive housing, hardware
and brackets; no ferrous metals used in the unit. Durable in harsh
atmospheres & outdoor environments.
• High temperature lead wires.
• Clear Quartz Lamp(s) Included.
67
Product SpecicationsReector Patterns
TH & THSS Series Mul-T-Mount Electric Infrared Heater
30° Symmetric
90° Symmetric
60° Asymmetric
30° Asymmetric
60° Symmetric
Reective
Pattern ( º )
Heater Output
(kW)
# of Qtz. Lamps
Mounting Heights (FT.) Watts Delivered per Square Foot
8 10 12 14 16 18 20 Mounting Heights (FT.)
Heat Pattern Coverage @ Floor Level
8 10 12 14 16 18 20
L x W L x W L x W L x W L x W L x W L x W
30º 3.2
2 - Quartz Lamp Heaters
5.5 x 4 6.5 x 5.5 7.5 x 6.5 8.5 x 7.5 9.5 x 8.5 10.5 x 9.5 11.5 x 10.5 145.5 89.5 65.6 50.2 39.6 32.1 26.5
60º 3.2 10.5 x 9.5 13 x 12 15 x 14 17 x 16
N / R N / R N / R
32.1 20.5 15.2 11.8 - - -
90º 3.2 17 x 16 21 x 20 N / R N / R 11.8 7.6 - - - - -
30º 5.0 6 x 4 7.5 x 5.5 8.5 x 6.5 9.5 x 7.5 10.5 x 8.5 11.5 x 9.5 12.5 x 10.5 208.3 121.2 90.5 70.2 56.0 45.8 38.1
60º 5.0 11.5 x 9.5 14 x 12 16 x 14 18 x 16 20.5 x 18.5 23 x 21
N / R
45.8 29.8 22.3 17.4 13.2 10.4 -
90º 5.0 18 x 16 22 x 20 26 x 24 N / R N / R N / R 17.4 11.4 8.0 - - - -
30º 7.3 N / R 8.5 x 5.5 9.5 x 6.5 10.5 x 7.5 11.5 x 8.5 12.5 x 9.5 13.5 x 10.5 - 156.1 118.2 92.7 74.7 61.5 51.5
60º 7.3 12 x 10.5 15 x 12 17 x 14 19 x 16 21.5 x 18.5 24 x 21 N / R 57.9 40.6 30.7 24.0 18.4 14.5 -
90º 7.3 19 x 16 23 x 20 27 x 24 N / R N / R N / R 24.0 15.9 11.3 - - - -
30º 4.8
3 - Quartz Lamp Heaters
5.5 x 5 6.5 x 6.5 7.5 x 7.5 8.5 x 8.5 9.5 x 9.5 10.5 x 10.5 11.5 x 11.5 174.5 113.6 85.3 66.4 53.2 43.5 36.3
60º 4.8 10.5 x 10.5 13 x 13 15 x 15 17 x 17 21 x 21
N / R N / R
43.5 28.4 21.3 16.6 10.9 - -
90º 4.8 17 x 17 21 x 21 N / R N / R N / R 16.6 10.9 - - - - -
30º 7.5 N / R 7.5 x 6.5 8.5 x 7.5 9.5 x 8.5 10.5 x 9.5 11.5 x 10.5 12.5 x 11.5 - 153.8 117.6 92.9 75.2 62.1 52.2
60º 7.5 11.5 x 10.5 14 x 13 16 x 15 18 x 17 20.5 x 19.5 23 x 22
N / R
62.1 41.2 31.3 24.5 18.8 14.8 -
90º 7.5 18 x 17 22 x 21 26 x 25 N / R N / R N / R 24.5 16.2 11.5 - - - -
30º 10.95 N / R 8.5 x 6.5 9.5 x 7.5 10.5 x 8.5 11.5 x 9.5 12.5 x 10.5 13.5 x 11.5 - 198.2 153.7 122.7 100.2 83.4 70.5
60º 10.95 12 x 11 15 x 13 17 x 15 19 x 17 21.5 x 19.5 24 x 22 N / R 83.0 56.2 42.9 33.9 26.1 20.7 -
90º 10.95 19 x 17 23 x 21 27 x 25 N / R N / R N / R N / R 33.9 22.7 16.2 - - - -
Sizing Chart
Series:
222, 342, 462 (Painted Version) 2-lamp
222, 342, 462 (Stainless Steel Version) 2-lamp
223, 343, 463 (Stainless Steel Version) 3-lamp
Housing:
20 gauge Galvanized Steel with a baked on, brown enamel (painted) nish. Housing is
ETL Listed for both indoor and totally exposed outdoor applications.
20 gauge Stainless Steel for durability and corrosion-resistance. Housing is ETL Listed
for both indoor and totally exposed outdoor applications.
Reectors and End Caps:
.040 Gold anodized Aluminum reectors and end caps for superior reectivity. Five
choices of reector patterns including 30 degree narrow (symmetric & asymmetric), 60
degree medium (symmetric & asymmetric), and 90 degree wide (symmetric).
Elements:
Clear quartz lamps. Coiled tungsten lament located within a sealed quartz envelope,
halogen lled, with porcelain end caps and 6” wire pigtail leads. 96% radiant delivered
efciency with high moisture and thermal shock resistance. Instantaneous heat-up
and cool-down performance. Available wattages from 500 to 3800 Watts per element.
Available voltages from 120 to 600 Volts.
Controls:
Mul-T-Mount heaters are not manufactured with any control device on the unit. All
controls are accessories and should be specied as such. Please consult the technical
sales department of factory for help in determining applicable controls. Please follow
installation instructions that accompany each heater.
Accessories:
Recessed mounting frames (painted or stainless steel), adjustable mounting brackets
(stainless steel only), vertical mounting brackets (stainless steel only), wire guards,
thermostats, snow detectors, SCR controllers, and power contactor panels.
68
TH & THSS Series Mul-T-Mount Electric Infrared Heater
2 Lamp Mul-T-Mount Series
Brown Enamel Or Stainless Steel With 2 Clear Quartz Lamps Included
NOTE: Consult the factory, the product instruction manual, or a licensed electrician for 3-phase wiring of all 2-element heaters.
BROWN HOUSING STAINLESS STEEL HOUSING
KW BTU’S VOLTS REFLECTOR
PATTERN
Replacement
Element
WT.
(Lbs.)
UPC
686334 MODEL UPC
686334 MODEL
444163 222-30-TH-208V 444408 222-30-THSS-208V
3.2 10,922
208
30° Symmetrical
63016209
20
444170 222-30-TH-240V 444415 222-30-THSS-240V 240 63016249
444187 222-30-TH-277V 444422 222-30-THSS-277V 277 63016279
481380 222-30-TH-480V 481434 222-30-THSS-480V 480 63016489
444194 222-A30-TH-208V 444439 222-A30-THSS-208V 208
30° Asymmetrical
63016209
444200 222-A30-TH-240V 444446 222-A30-THSS-240V 240 63016249
444217 222-A30-TH-277V 444453 222-A30-THSS-277V 277 63016279
481410 222-A30-TH-480V 481465 222-A30-THSS-480V 480 63016489
444224 222-60-TH-208V 444460 222-60-THSS-208V 208
60° Symmetrical
63016209
444231 222-60-TH-240V 444477 222-60-THSS-240V 240 63016249
444248 222-60-TH-277V 444484 222-60-THSS-277V 277 63016279
481397 222-60-TH-480V 481441 222-60-THSS-480V 480 63016489
444255 222-A60-TH-208V 444491 222-A60-THSS-208V 208
60° Asymmetrical
63016209
444262 222-A60-TH-240V 444507 222-A60-THSS-240V 240 63016249
444279 222-A60-TH-277V 444514 222-A60-THSS-277V 277 63016279
481427 222-A60-TH-480V 481472 222-A60-THSS-480V 480 63016489
443296 222-90-TH-208V 444521 222-90-THSS-208V 208
90° Symmetrical
63016209
444286 222-90-TH-240V 444538 222-90-THSS-240V 240 63016249
444293 222-90-TH-277V 444545 222-90-THSS-277V 277 63016279
481403 222-90-TH-480V 481458 222-90-THSS-480V 480 63016489
481083 342-30-TH-208V 480932 342-30-THSS-208V
5.0 17,065
208
30° Symmetrical
63025209
25
481090 342-30-TH-240V 480949 342-30-THSS-240V 240 63025249
802611 342-30-TH-480V 802635 342-30-THSS-480V 480 63025489
481175 342-A30-TH-208V 481021 342-A30-THSS-208V 208
30° Asymmetrical
63025209
481182 342-A30-TH-240V 481038 342-A30-THSS-240V 240 63025249
444316 342-A30-TH-480V 444569 342-A30-THSS-480V 480 63025489
481113 342-60-TH-208V 480963 342-60-THSS-208V 208
60° Symmetrical
63025209
481120 342-60-TH-240V 480970 342-60-THSS-240V 240 63025249
802918 342-60-TH-480V 802932 342-60-THSS-480V 480 63025489
481205 342-A60-TH-208V 481052 342-A60-THSS-208V 208
60° Asymmetrical
63025209
481212 342-A60-TH-240V 481069 342-A60-THSS-240V 240 63025249
444330 342-A60-TH-480V 444583 342-A60-THSS-480V 480 63025489
481144 342-90-TH-208V 480994 342-90-THSS-208V 208
90° Symmetrical
63025209
481151 342-90-TH-240V 481007 342-90-THSS-240V 240 63025249
803212 342-90-TH-480V 803236 342-90-THSS-480V 480 63025489
802710 462-30-TH-480V 802734 462-30-THSS-480V
24,915 480
30° Symmetrical 63036489
32
444361 462-A30-TH-480V 444613 462-A30-THSS-480V 30° Asymmetrical 63036489
803014 462-60-TH-480V 803038 462-60-THSS-480V 7.3 60° Symmetrical 63036489
444385 462-A60-TH-480V 444637 462-A60-THSS-480V 60° Asymmetrical 63036489
803311 462-90-TH-480V 803335 462-90-THSS-480V 90° Symmetrical 63036489
69
THSS Series Mul-T-Mount Electric Infrared Heater
TH & THSS Series Product Accessories
3 Lamp Mul-T-Mount Series
Stainless Steel Housing With 3 Clear Quartz Lamps Included
NOTE:
• 600-Volt Models also available, contact factory
for more information.
• Asymmetrical pattern units are also available
for 30° & 60°
Manufactured in U.S.A.
UPC#
686334 MODEL KW BTU’S VOLTS Reector
Pattern
Replacement
Elements
WT.
(Lbs.)
443678 223-30-THSS-208V
4.8 16382
208
30°
Symmetrical
63016209
25
443685 223-30-THSS-240V 240 63016249
443692 223-30-THSS-277V 277 63016279
481588 223-30-THSS-480V 480 63016489
443289 223-60-THSS-208V 208
60°
Symmetrical
63016209
443739 223-60-THSS-240V 240 63016249
443746 223-60-THSS-277V 277 63016279
481595 223-60-THSS-480V 480 63016489
443784 223-90-THSS-208V 208
90°
Symmetrical
63016209
443791 223-90-THSS-240V 240 63016249
443807 223-90-THSS-277V 277 63016279
481601 223-90-THSS-480V 480 63016489
481236 343-30-THSS-208V
7.5 25298
208
30°
Symmetrical
63025209
33
481243 343-30-THSS-240V 240 63025249
811439 343-30-THSS-480V 480 63025489
481267 343-60-THSS-208V 208
60°
Symmetrical
63025209
481274 343-60-THSS-240V 240 63025249
811637 343-60-THSS-480V 480 63025489
481298 343-90-THSS-208V 208
90°
Symmetrical
63025209
481304 343-90-THSS-240V 240 63025249
811835 343-90-THSS-480V 480 63025489
810531 463-30-THSS-480V
37372 480
30° Sym. 63036489
41810739 463-60-THSS-480V 10.95 60° Sym. 63036489
810937 463-90-THSS-480V 90° Sym. 63036489
UPC MODEL DESCRIPTION FOR USE WITH WT.
(LBS.)
686334
881128 VMB-41-SS Wall Mounting Brackets (2) All Mul-T-Mount Models 12
851152 CHWG-222
Stainless Steel Wire Guards
222 Series
2
851145 CHWG-342 342 Series
851626 CHWG-462 462 Series
854368 CHWG-223 223 Series
854351 CHWG-343 343 Series
854344 CHWG-463 463 Series
Recessed Mounting Frames (UL)
Ceiling Cutout (in.) Frame Size (in.)
441995 RMF-222-SS-A 27 x 17-7/8 29-1/8 x 20 222 Series Stainless 6
449441 RMF-222-A 27 x 17-7/8 29-1/8 x 20 222 Series Painted
442077 RMF-342-SS-A 36 x 17-7/8 38-1/8 x 20 342 Series Stainless 9
441872 RMF-342-A 36 x 17-7/8 38-1/8 x 20 342 Series Painted
442107 RMF-462-SS-A 49 x 17-7/8 51-1/8 x 20 462 Series Stainless 11
449458 RMF-462-A 49 x 17-7/8 51-1/8 x 20 462 Series Painted
881104 RMF-223-SS 32 x 29-3/8 34-1/8 x 31-1/2 223 Series Stainless 15
881135 RMF-343-SS 41 x 29-3/8 43-1/8 x 31-1/2 343 Series Stainless 18
881111 RMF-463-SS 54 x 29-3/8 56-1/8 x 31-1/2 463 Series Stainless 20
440783 31939009 Red Vycor Sleeves All 1600W Qtz. Lamp
2440738 31940009 Reduces Quartz Lamp All 2500W Qtz. Lamp
440745 31941009 Brightness by 90% All 3650W Qtz. Lamp
446150 632-1620 Red Quartz Lamps; 1.6kw, 208v 222,223 & RPH Series 2446167 632-1624 Red Quartz Lamps; 1.6kw, 240v
446228 632-2548 Red Quartz Lamps; 2.5kw, 480v 342 & 343 Series
70
OCH Series Outdoor / Indoor Rated Quartz Electric Infrared Heater
Features
• Frosted Quartz Tube heating element (included)
• Listed for suspended, totally exposed (outdoor) and indoor
spot heating applications
• Finish: High-temp brown powder coated nish or corrosion
resistant stainless steel 24 gauge housing
• 60° Symmetric Heat Pattern
• Gold anodized Aluminum reector and end caps
• Painted models are direct wire, unless specied and are
supplied with 6” lead wires for eld connection in the
internal wiring compartment. These models are available
with a factory installed 6’ cord set. The 208V model must
have a eld supplied plug.
• Stainless steel models include an electrical enclosure
assembled to the end of the heater housing and (2) 6” long
lead wires for direct eld connection.
• Two 2’ ft. long mounting chains and four S-Hooks included
• The OCH-Series can be surfaced mounted using the supplied
mounting brackets which allow up to a 45° horizontal tilt
adjustment.
Product Models
Product Accessories
Manufactured in U.S.A.
Heats solid objects, not the air!
UPC#
686334 MODEL DESCRIPTION FOR USE WITH WT.
(LBS.)
480888 OCHWG-46
Stainless Steel Wire Guards
OCH-46 Series Models 2
480895 OCHWG-57 OCH-57 Series Models 2
881128 VMB-41-SS Wall Mtg. Brackets (2) ALL OCH Models 12
445948 VHC-15 Variable Heat Controller ALL OCH Models 3
485357 VHC-32 Variable Heat Controller ALL OCH Models 3
FINISH - BROWN FINISH - STAINLESS STEEL
CONNECTION
TYPE WATT S BTU’S VOLTS AMPS
Qtz. Tube
Repl.
Element
WT.
(LBS.)
Includes Electrical Enclosure
UPC#
686334 MODEL UPC#
686334 MODEL
480444 OCH-46-120VE 480529 OCH-46-120V-SSE
Hard Wire
1500 5120 120 12.5 671-3784
10
480451 OCH-46-208VE 480536 OCH-46-208V-SSE 2000 6826 208 9.6 671-5061
480468 OCH-46-240VE 480543 OCH-46-240V-SSE 2000 6826 240 8.3 671-3785
480475 OCH-46-277VE 480550 OCH-46-277V-SSE 2000 6826 277 7.2 671-5018
480499 OCH-57-208VE 480574 OCH-57-208V-SSE 3000 10239 208 14.4 671-5060
12
480482 OCH-57-240VE 480567 OCH-57-240V-SSE 3000 10239 240 12.5 671-3786
480505 OCH-57-277VE 480581 OCH-57-277V-SSE 3000 10239 277 10.8 671-5059
480512 OCH-57-480VE 480598 OCH-57-480V-SSE 2250 7679 480 4.7 671-5058
485975 OCH-46-120VCE --- ---
Corded
1500 5120 120 12.5 671-3784 11
485982 OCH-57-208VCE --- --- 2000 6826 208 9.6 671-5061
13
485999 OCH-57-240VCE --- --- 2000 6826 240 8.3 671-3785
71
Mounting Height Heater Model Watts Heat Pattern Coverage ( at oor level) Total Watts /
Sq. Ft.
Length Width Sq. Ft.
7’ OCH-46 1500 11 9 99 15.2
OCH-46 2000 11 9 99 20.2
8’
OCH-46 1500 12 10 120 12.5
OCH-46 2000 12 10 120 16.7
OCH-57 3000 13 10 130 23.1
OCH-57 2250 13 10 130 17.3
9’
OCH-46 1500 13 11 143 10.5
OCH-46 2000 13 11 143 14.0
OCH-57 3000 14 11 154 19.5
OCH-57 2250 14 11 154 14.6
10’ OCH-57 3000 15 12 180 16.7
OCH-57 2250 15 12 180 12.5
12’ OCH-57 3000 17 14 238 12.6
OCH-57 2250 17 14 238 9.5
OCH Sizing Chart
Mounting Clearances & Recommended Mounting Height
Mounting Clearances Recommended Mounting Height
3” from ceiling; 12” from vertical surface
72” from face of heater to combustible surface
36” from another heater
OCH-46 7’-9’
OCH-57 8’-10’
Mounting
• Chain, surface mount or use our vertical mounting bracket as shown below. (Note:) All units must be mounted horizontally.
• In-Built surface mounting bracket allows for xture adjustment up to a 45° horizontal tilt.
• As shown, the heater may be suspended at any horizontal angle desired.
Optional Vertical Mounting Bracket:
Model # VMB-41-SS
Chain Mount:
(Chain supplied)
OCH-46
Length: 44.4’’
Width: 5.4’’
Height: 6.5’’
OCH-57
Length: 55.4’’
Width: 5.4’’
Height: 6.5’’
Reector Pattern:
Product Specications
Mounting Congurations & Reector Pattern
OCH Series Outdoor / Indoor Rated Quartz Electric Infrared Heater
Series:
OCH-46 & OCH-57
Housing:
24 gauge Aluminized Steel with a baked on brown powder coat finish. Housing is cETLus Listed for indoor or outdoor
applications. Horizontal mounting only.
Reflectors and End Caps:
.040 Gold anodized Aluminum reflectors and end caps for superior reflectiveness. 60 degree medium (symmetric) pattern only.
Elements:
Quartz Tubes. Frosted quartz envelope with a Nickel-Chromium coiled filament, porcelain end caps, and threaded-screw (stud)
terminations. Fast heat-up and cool-down performance. Available Wattages from 1500 to 3000 Watts per element. Available
voltages from 120 to 480 Volts.
Controls:
OCH Series heaters are not manufactured with any control device on the unit. All controls are accessories and should be specified
as such. Please consult the technical sales department of factory for help in determining applicable controls. Please follow
installation instructions that accompany each heater.
Accessories:
Adjustable mounting brackets (stainless steel only), vertical mounting brackets (stainless steel only), wire guards, thermostats,
SCR controllers, and power contactor panels.
72
RPH Series Outdoor Rated Stainless Steel Electric Infrared Heater
MM Series “Mitey Midget” Electric Infrared Heater
FFH Series Electric Utility Infrared Heater
Mounting Plate (provided)
on top center allows heater
to be mounted parallel or
angled using a standard
pipe nipple and box cover
(supplied by installer)
• Instant, high-intensity radiant heat, with 30° symmetric heat pattern.
• Listed for indoor spot heating and for outdoor unprotected applications.
• Specialized Ruby “Red” Quartz Lamp infrared heating element for glare reduction.
• Stainless Steel housing with Coilzak Aluminum reector for good reectivity & corrosion
resistance.
• Heating element and mounting plate included.
• Dimensions: 24” x 5-3/8” x 4-1/2.”
Mounting Clearances Recommended Mounting Height
6” from ceiling
24” from vertical surface
72” from face of heater to combustible surface
RPH-208 8’-12’
RPH-240 8’-12’
All MM-13A through MM-46A models are ETL Listed for use with Quartz Lamps Only!
Mounting Clearances
24” from ceiling & from vertical surface
24” from face of heater to combustible surface
36” from another heater
• Instant, high-intensity radiant heat, with 60° symmetric heat pattern.
• MM heaters excel as people-heaters in areas requiring a linear, compact & concentrated heat source.
• Listed for indoor industrial and commercial comfort heat applications.
• Heavy duty Aluminum extrusion with a bright
Aluminum insert for maximum reectivity.
• Anodized Aluminum housing, (0.62” thick).
• Heat Element Sold Separately.
• Dimensions: 3.750” Wide x 3.380” High.
Mounting Clearances
3” from ceiling
24” from vertical surface
72” from oor
FFH-512A
FFH-912B
• Both FFH Series Heaters are excellent for Farrowing & Finishing applications.
• Both units feature an 8 ft. 18/3 grounded cordset to plug into any 120V service.
• Gold anodized Aluminum reectors, with a 90° symmetrical reector pattern.
• Compact housing design, with the following housing nish:
FFH-512A: Gold Anodized Finish
FFH-912B: Brown Enamel Finish
• Quartz Tubes Heat Element(s), Wire Guard & (2) 4’ ft. Jack Chains are included.
• FFH-912B Only: Offers (2) On/Off
toggle switches to operate heating
elements independently.
• Listed for indoor industrial and
commercial comfort heat
Manufactured in U.S.A.
Manufactured in U.S.A.
Manufactured in U.S.A.
SIZING CHART - FFH SERIES
MOUNTING
HEIGHT
Heater
Model LENGTH WIDTH COVERAGE
(Sq. Ft.)
WATTS
/ Sq. Ft.
6’ FFH-512A 7 6 42 13.1
FFH-912B 6 7 42 21.4
7’ FFH-512A 8 7 56 9.8
FFH-912B 7 8 56 16.1
8’ FFH-512A 9 8 72 7.6
FFH-912B 8 9 72 12.5
UPC
686334 MODEL MAX
WATTS
MAX
BTU'S VOLTS PH UNIT
LENGTH WT. (LBS.)
Optional Wireguards
UPC
686334 MODEL
444019 MM-13A 500 1707 120 1 13" 3 443906 MMWG-13
442763 MM-18A 750 / 1000 3413 208-240 1 18" 4 443913 MMWG-18
449540 MM-24A 900 / 1600 5461 208-277 1 24" 5 441896 MMWG-24
442725 MM-33A 2500 8533 480 1 33" 6 443920 MMWG-33
442039 MM-46A 3000 / 3800 12457 480-600 1 46" 7 442046 MMWG-46
UPC#
686334 MODEL WATT S BTU’S VOLTS PHASE AMPS REPLACEMENT
QUARTZ LAMP
WT.
(LBS.)
Optional Wireguard
UPC# 686334 MODEL
884501 RPH-208-A 1600 5,461 208 1 7.7 632-1620 5 880992 RPHWG
884518 RPH-240-A 1600 5,461 240 1 6.7 632-1624 5
UPC#
686334 MODEL WATT S BTU’S VOLTS PHASE AMPS REPLACEMENT
QUARTZ TUBE
WT.
(LBS.)
Dimensions (in.)
Length Width Height
883894 FFH-512A 550 1877 120 1 5 671-3492 4 22 5 3
882781 FFH-912B 450/900 3072 120 1 8 671-3454 4 17 6 4
73
Electric Infrared Heating Elements
Clear & Red Quartz Lamps
Quartz Tubes
Metal Sheath Elements
Notes: Life expectancy of all heating elements - 5,000 hours (4yr. Pro-rated Warranty).
All heating elements operate at 50 / 60 Hertz.
• 3/8” Diameter clear or red quartz envelope.
• Coiled tungsten lament; sealed porcelain end caps; halogen gas lled.
Model Sufx: 630 = Horizontal Burning “Clear”; 631 = Vertical OR Horizontal Burning “Clear”; = Horizontal Burning “Red”
Note: Inner reector shipped with replacement Metal Sheath Elements.
*3/8” Diameter
• 5/8” Diameter frosted quartz envelope
• Nickel-Chromium alloy coiled
element with porcelain end caps and
pigtailed termination
• Color temperature emitted: approx.
1800° F (bright orange glow)
• Approximately 60% radiant efciency
• Fast heat-up/cool-down
• Moisture resistance: High
• Mechanical ruggedness: Good
Notes: Life expectancy of all heating elements - 5,000 hours.
All heating elements operate at 50 / 60 Hertz.
Notes: Life expectancy of all heating elements - 5,000 hours.
All heating elements operate at 50 / 60 Hertz.
• Color temperature emitted: approx. 4100° F (high brightness).
• Approximately 96% radiant efciency.
• Excellent resistance to thermal shock.
• 0.430” Diameter
Incoloy metal
sheath envelope
• Nickel-
Chromium alloy
coiled element
imbedded in
Magnesium
Oxide insulating
powder
• Color
temperature
emitted: approx.
1600° F (dull
orange glow)
• Approximately
50% radiant
efciency
• Slowest heat-up/
cool-down
• Moisture
resistance:
Lowest
• Mechanical
ruggedness:
Highest
UPC Item # Watts Volts Length (in.) Fits UPC Item # Watts Volts Length (in.) Fits
686334 Overall Heated Model 686334 Overall Heated Model
440059 630-05129 500 120 8-11/16 5 MM-13A 440363 631-25489 2500 480 28-11/16 25 342, 343 or
MM-33A
442770 630-10209 1000 208 13-11/16 10 MM-18A 440684 631-25609 600
444118 630-10249 240 ---- ---- ---- ----
41-11/16 38 462, 463 or
MM-46A
440165 630-16209
1600
208
19-11/16 16 222, 223 or
MM-24A
---- ---- ---- ----
440172 630-16249 240 440677 630-36489 3650 480
440998 631-16249 240 446235 630-38579 3800 600
440189 630-16279 277 444132 631-38579 3800 600
481731 630-16489 480 RED QUARTZ LAMPS
481748 630-25209
2500
208
28-11/16 25 342, 343 or
MM-33A
481755 630-25249 240 446150 632-1620 1600 208 19-11/16 16 222/223
481762 630-25279 277 446167 632-1624 1600 240 19-11/16 16 or RPH
440547 630-25489 480 446228 632-2548 2500 480 28-11/16 25 342 or 343
UPC#
686334 MODEL WATT S VOLTS LENGTH (in) Replacement Heating Element
Overall Heated Fits “CH-Models” Fits “FHK Models”
445870 641-37211 1800 120
23-1/16 18
CH-212-1A FHK-212-1CA
445832 641-35661
2000
208 CH-220-1A, CH-620-3A
FHK 2.0 & 6.0 KW
Models
445795 641-35611 240 CH-224-1A, CH-624-3A
445849 641-36051 277 CH-277-1A, CH-627-3A
445801 641-35621 480 CH-248-1A, CH-648-3A
445887 641-50011 600 CH-257-1A, CH-657-3A
445856 641-36061
4500
208
44-7/16 39
CH-420-1A, CH-1320-3A, CH-2720-3B
FHK 4.5 & 13.5 KW
Models
445818 641-35631 240 CH-424-1A, CH-1324-3A, CH-2724-3B
445863 641-36071 277 CH-427-1A, CH-1327-3A
446174 641-35641 480 CH-448-1A, CH-1348-3A, CH-2748-3B
445894 641-50021 600 CH-457-1A, CH-1357-3A, CH-2757-3B
UPC#
686334 MODEL WATT S VOLTS LENGTH (in) Replacement Heating Element
Overall Heated Fits “CH-Models” Only
445788 641-70321 1800 120
24-1/16 18
CH-212-1C
445702 641-70241
2000
208 CH-220-1C, CH-620-3C
445719 641-70251 240 CH-224-1C, CH624-3C
445726 641-70261 277 CH-227-1C, CH-627-3C
445733 641-70271 480 CH-248-1C, CH-648-3C
445771 641-70281 600 CH-257-1C, CH-657-3C
445597 641-70001
4500
208
45-7/16 39
CH-420-1C, CH-1320-3B, CH-2720-3C
445603 641-70011 240 CH-424-1C, CH-1320-3B, CH-2720-3C
445610 641-70021 277 CH-427-1C, CH-1327-3B
445627 641-70031 480 CH-448-1C, CH-1348-3B, CH-2748-3C
445665 641-70041 600 CH-457-1C, CH-1357-3B, CH-2757-3C
UPC
686334 Item # Watts Volts Length (in.) Fits
Overall Heated Model
443234 671-3784 1500 120 39-11/16 34-3/16
OCH-46
441810 671-5061 2000 208 39-11/16 34-3/16
441803 671-3785 2000 240 39-11/16 34-3/16
441933 671-5018 2000 277 39-11/16 34-3/16
441667 671-5060 3000 208 50-11/16 45-3/16
OCH-57
441476 671-3786 3000 240 50-11/16 45-3/16
441940 671-5059 3000 277 50-11/16 45-3/16
441957 671-5058 2250 480 50-11/16 45-3/16
440356 671-3454 450 120 12-15/16 8-7/16 FFH-912B
440080 671-3492* 550 120 19-1/2 16 FFH-512A
446242 671-5056 1000 120 18-5/16 14-7/16 CH-2212-1C
446259 671-5057 1425 240 27-5/16 23-7/16 CH-6424-1C
74
Electric Infrared Heating Controls
Snow & Ice Detectors
Variable Controllers
APS-3C
CIT-1
• Main control unit for Automatic Snow & Ice Control Systems.
• By sensing both temperature and moisture the system activates and melts any
snow & ice accumulations until conditions subside.
• NEMA 3R Enclosure is UL Listed and houses timers and switching electronics
to operate the system.
• Capability to monitor up to 6 sensors (CIT-1).
• Unit can be manually activated and can be controlled and monitored from an
optional remote switch (Model RCU-).
• Positioned above ground to maximize the sensors capability.
• Detects falling or blowing of precipitation such as snow when the
temperature is below 38° F.
• Most common sensor device.
Note: Any snow & ice control system should be used with the correct sized control panel (with contactors & fusing) as supplied by factory or
your electrical contractor. Also, the APS-3C requires a control device (RCU-1, CIT-1, SIT-6E) in order to operate properly.
VHC-15
18D-2-80CF ENC.
VHC-32
30-Amp or 80-Amp Enclosed
Manufactured in U.S.A.
Manufactured in U.S.A.
Manufactured in U.S.A.
Manufactured in U.S.A.
• Solid state variable device controls
heat loads up to 15-Amps.
• 208/240Volt “In-Line” Controller.
• Built in On/Off knob switch with
positive “off” & surface plate
included.
• Designed for a 2” x 4” electrical
wall box mounting (not supplied).
• Must be mounted in a protected
area.
• Can only operate Fostoria Quartz
Tube Infrared Heaters.
• SCR Voltage Controller - 80 Amp MAX.
• Includes (1) 24-volt Potentiometer (3” square)
to control the heat output.
• Only operates Quartz Lamps at 240 or
208-Volts, single phase only.
• Potentiometer can be mounted outside, but the
SCR must be located in a protected area.
• Factory wired with millisecond fuses included.
• Solid State phase angle variable
“Triac” knob controller adjusts
heat settings from 10-100% with
heat loads up to 15.4-Amps.
• 208/240 VAC single-phase, single
stage controller, 3200 Watt max.
• Positive “Off” & built-in On/Off
Rocker switch lights “red” during
operation.
• NEMA 1 Aluminum enclosure with
stainless steel face plate designed
for wall mounting or suitable for
semi-recessed applications.
• Must be mounted in a protected
area.
• Can either operate Quartz Lamps
or Quartz Tube Infrared Heaters.
Note: Installer to provide overload protection for all infrared heaters.
Contactor Enclosures
• Economical load handling / switch device, ideal for use with other control equipment.
• NEMA 1 Enclosures.
• Load rating up to 600V Max., 3-Pole.
• Magnetic contactor.
FEC-30-120
Manufactured in U.S.A.
UPC#
686334 Model Description Dimension (In.) Wt.
Depth Width Height
319614 APS-3C Snow / Ice Control Switch 6.56 11.5 9.25 8 lbs.
319761 CIT-1 General Purpose Snow Sensor 3.25 3.25 4.13 1 lb.
UPC Model Description Dimension (In.) Wt.
686334 Depth Width Height
485357 VHC-32 Variable Heat Controller 208/240-Volt; 15.4 Amp 3 5 5 3 lbs.
445948 VHC-15 Variable Heat Controller; 208/240-Volt; 15 Amp 3 5 5 3 lbs.
445634 18D-2-30CF (Open) SCR Controller - 26 Amp MAX; No Enclosure 6 6 9 11 lbs.
445641 18D-2-30CF (Enclosed) SCR Controller - 26 Amp MAX; Enclosure Included 8 10 12 15 lbs.
445658 18D-2-80CF (Enclosed) SCR Controller - 80 Amp MAX; Enclosure Included 8 12 14 29 lbs.
UPC
686334 Model Contactor
Amps
Coil
Voltage
Cabinet Size (In.) Wt.
(LBS.)
Depth Width Height
440851 FEC-30-120 30 120
5 6 10 5
440868 FEC-30-240 208/240
440875 FEC-60-120 60 120
440882 FEC-60-240 208/240
75
Electric Infrared Heating Controls
Pre-Wired Contactor Panels
FPC2120
• Factory pre-wired for quick installation,
with the following optional equipment:
Snow & Ice Detector (APS-3C)
Single & Two-Stage Thermostats
Two-stage thermostats require a
minimum 2-contactors.
Note: Contact factory for 3R, 4, 4X, & NEMA 12 “special” built models.
• Step-down transformer and secondary
fusing for 24V or 120V control circuit.
• 3-Phase load rated.
• Fuses are NOT included.
• NEMA 1 Enclosures.
• Max 50-Amp branch circuit fusing.
IMPORTANT FUSING INFORMATION
Fuses are NOT included since panels can be used with various infrared heat sources. Quartz
Lamp Heat Sources: Use FRS-600V (or equal) “Time Delay” fuses; Class RK-5. Quartz Tube
& metal Sheath Heat Sources: Use KTS-R 600V (or equal) “Fast Acting” fuses; Class RK-1.
Fuse circuits as close to calculated load as possible. Circuits less than 35 Amps will require the
use of fuse reducers.
Manufactured in U.S.A.
Standard Models
120-V CONTROL SYSTEM 24-V CONTROL SYSTEM
MAX
AMPS VOLTS
CABINET SIZE (IN.)
WT.
(LBS.)
UPC# 686334 MODEL UPC# 686334 MODEL DEPTH WIDTH HEIGHT
4459902 FPC8110 4864302 FPC8210
50
208
6.75 16 24 52
4460002 FPC2110 4864402 FPC2210 240
4460102 FPC7110 4864502 FPC7210 277/480
4460202 FPC4110 4864602 FPC4210 480
4460302 FPC8120 4864702 FPC8220
100
208
6.75 16 24 70
4460402 FPC2120 4864802 FPC2220 240
4460502 FPC7120 4864902 FPC7220 277/480
4460602 FPC4120 4865002 FPC4220 480
4460702 FPC8140 4865102 FPC8240
200
208
6.75 24 30 88
4460802 FPC2140 4865202 FPC2240 240
4460902 FPC7140 4865302 FPC7240 277/480
4461002 FPC4140 4865402 FPC4240 480
4461102 FPC8160 4865502 FPC8260
300
208
6.75 30 36 106
4461202 FPC2160 4865602 FPC2260 240
4461302 FPC7160 4865702 FPC7260 277/480
4461402 FPC4160 4865802 FPC4260 480
76
FHK Series Portable Metal Sheath Electric Infrared Heater
Standard FHK Models
•
Double side wall housings to reduce operating temperatures.
• 6.0 and 13.5KW heaters have double top bafes to reduce
operating temperatures.
• 60° symmetrical heat pattern.
• Factory installed U-shaped metal sheath infrared heating
elements have an average 5000 hour life.
• Heavy duty protective wire screens.
• GOLD anodized Aluminum internal reector.
• Ground fault protection must be used.
2.0KW & 4.5KW
Stand Models 6.0KW & 13.5KW
Hand Cart Models
Square Feet Heated
KW
NON-PROTECTED
AREA
SEMI-PROTECTED
AREA
Required
Clearance
From Front
of Heater
BELOW ABOVE BELOW ABOVE
35 oF 35 oF 35 oF 35 oF
1.8 / 2.0 25 36 40 50 2 feet
4.5 64 75 90 125 3 feet
685 100 120 150 4 feet
13.5 192 225 270 375 7 feet
Contact Factory for Special Build Models @ 208V, 277V or 600V.
Factory Pre-Wired FHK Models With 15 Ft. Cord & Grounded Plug
FHK Infrared Control Options
Model “TO” & “GF” features
include a positive “off” & a
built-in on/off rocker switch
that glows red during operation.
Additionally, enclosure can
mount directly to the terminal
box on the back of the heater
(FHK-6/13 only) or be mounted
to a remote wall surface.
TO-SK-1
or GF-SK-1
Manufactured in U.S.A.
UPC#
686334 MODEL TYPE KW BTU's VOLTS PHASE AMPS W T.
881715 FHK-212-1CA STAND 1.8 6,143 120 1 15.0 18 lbs.
882798 FHK-624-1CA CART 6.0 20,478 240 1 25.0 40 lbs.
UPC
686334 MODEL # DESCRIPTION Operating
Voltage (VAC)
Dimensions (In) WT.
(lbs.)
Ht. Wd. Dp.
485814 TO-SK-1 Tip-Over Switch 208V - 600V 10.3 10.3 5.0 12
589376 DC-SK-1 Disconnect Switch 120V - 600V 5.0 6.0 4.0 5
486026 GF-SK-1 Ground Fault Sensing Switch 208V - 600V 10.3 10.3 5.0 12
Note: All SK-1 Models have NEMA-1 Enclosure, 50-Amp Max. & 1/3-Phase Rated.
UPC#
686334 MODEL KW BTU's VOLTS PH AMPS WT.
OPTIONAL 25' POWER CORD
UPC#
686334 MODEL
881739 FHK-224-1A
2.0 6,826
240 1 8.3
17 lbs.
880435 SO 16/3
881753 FHK-248-1A 480 1 4.2 880435 SO 16/3
881784 FHK-424-1A
4.5 15,359
240 1 18.8
24 lbs.
880459 SO 12/3
881807 FHK-448-1A 480 1 9.4 880466 SO 14/3
882910 FHK-624-3A
6.0 20,478
240
3 14.4
37 lbs.
880497 SO 14/4
1 25.0 880442 SO 10/3
882934 FHK-648-3A 480
3 7.5 880497 SO 14/4
1 13 880466 SO 14/3
882965 FHK-1324-3A
13.5 46,076
240 3 33.0
65 lbs.
880510 SO 8/4
882989 FHK-1348-3A 480
3 17.0 316422 SO 12/4
1 29.0 880527 SO 8/3
77
30 AMP Plug
NEMA #6-30P
20 AMP Plug
NEMA #6-20P
20 AMP Plug
NEMA #5-20
PCH Series Portable Quartz Infrared Spot Heater Portable Infrared Instant On-Off Heat Gun
CH Series Portable Quarts Infrared Heater
MODEL CH 2212-1C has two 1000 Watt elements that can be switched on / off by toggle switches
to produce 1000 Watts or 2000 Watts of heat. - 15’ cord and NEMA 5-20 molded plug.
MODEL CH 6424-1C has two sets of 1425 Watt elements that can be switched on / off by toggle
switches to produce 2850 Watts or 5700 Watts of heat. - 15’ cord and NEMA L6-30 twist lock plug.
• 60° symmetrical heat pattern. • Quartz tubes and built in wire guards included.
• Interior or protected outdoor use only. • GOLD anodized Aluminum reector and end caps.
Chain mounted
CH 2212-1C
Portable Cart Unit CH 6424-1C
with FHK-1 Cart
Listed
for
overhead
operation
Note: CH-2212-1C operates
with a 20- Amp molded plug. Note: CH-6424-1C operates
with a 30- Amp twist lock plug.
Manufactured in U.S.A.
Features
Portable Electric Infrared Heat Panels
HP-11-QT
• Portable panels are built to withstand rigors of industrial and heavy-commercial applications,
such as auto collision repair shops.
• 20 gauge Steel frame, base, and housing construction.
• 3” Steel casters for high stability and ease of mobility
• Gold anodized Aluminum reectors and end caps allow 10% faster cure time than polished
Aluminum reectors, especially in paint and dust-laden atmospheres.
• Elements achieve full temperature in less than 2 minutes
• Fused disconnect switches are installed on the back of each unit.
• Units are positioned with adjustable hinges allowing the user to use direct heat more precisely
to the target area.
• Gentle but effective medium-wave radiant heat can quickly boost, ash-off, or cure a variety
of nishes, and lessens the chance of blistering and/or overheating the coating.
• Medium-wave infrared heating elements are also effective for ash-off of water-based clear
coatings being mandated by environmental agencies in many states.
Features
Standard Models
General Curing Guidelines
Note: Curing times will vary depending on material and shop conditions. This chart is based on distances of 18-24” away from the target area.
Material Type Solvent Based
Primer
Water Based
Primer
Two Component
Primer
Water Based
Clear Coat
Acrylic enamel &
Polyurethane Clear Coat
Urethane Clear Coat &
High Solids Top Coat
Curing Time 3-5 mins 3-6 mins 8-20 mins 3-10 mins 12-30 mins 10-30 mins
HP-5-QT
Width: 53”
Height: 2-6’
Depth: 28”
Features
• Provides instant spot heat in a
controlled pattern
• Spot cure retouched paint and other
nishes
• De-wrinkle or relax materials such
as cloth-vinyl-leather
• T-3 Tungsten IR lamp
• Spring loaded power button switch
• Suitable for portable spot heat or for curing
clear coat paint
• Height adjustable from 2’ to 4’
• On-Off rocker switch standard
• 4 casters included; Tip-Over power cutoff
safety switch
• 60o symmetrical heat pattern
• 5/8” diameter quartz tube included
• Average element life is 5000 hours
• Bright Aluminum reector and end caps
• 20 gauge powder coated Steel housing
• 15’ long, 3 wire (14/3) cordset with standard 3 pring NEMA 5-20P
• 10’ long, 18/3 grd. cordset with NEMA plug
UPC 686334 MODEL KW BTU's VOLTS PHASE AMPS WT.
884099 CH-2212-1C 2.0 / 1.0 6826 / 3413 120 1 16.7 / 8.35 16 lbs.
884105 CH-6424-1C 5.7 / 2.85 19454 / 9727 240 1 23.8 / 11.9 31 lbs.
852401 FHK-1 OPTIONAL CART 20 lbs.
UPC# Model WATTS VOLTS AMPS HEAT
SOURCES
CABLE
TYPE (20’)
Dimension (In.) Heated Area (In.) Wt.
686334 Width Height Width Height
884129 HP-5-QT 4,800
240
20 4 12-3 SO 44-5/8 56-1/2 40 44 116
884136 HP-6-QT 6,400 26.7 4 66-5/8 61 141
884143 HP-11-QT 11,200 46.7 7 6-3 SO 89-1/2 77 225
UPC#
686334 MODEL WATT S BTU’s VOLTS PHASE WT.
884112 PCH-48C 1500 5120 120 1 30
UPC#
686334 MODEL WATT S VOLTS AMPS WT.
592284 RHG-1012A
1000 120 8.4 3
592277 RHG-1012B
78
FES & YES Series Heat WaveTM Portable Electric & Wall or Ceiling Mounted Salamander
Standard FES Models
FES Series Product Features & Information
• Safety yellow heater enclosure with safety screens on both air intake and
output openings.
• Optional 25’ long SO type cord, ready for plug attachment is available for
each model.
• Long-life nned tubular heating elements.
• Thermostat adjustment 40° to 100° F.
• Magnetic contactor.
• Automatic reset.
• High-limit thermal cutout switch.
• Fan only switch.
• 10” wheels.
• 800 CFM-15KW units - 1100 CFM-30KW units.
AVERAGE MINUTES TO ACHIEVE TEMPERATURE RISE*
BUILDING SIZE: 1000 SQ. FEET 1500 SQ. FEET 2000 SQ. FEET
TEMP RISE TEMP RISE TEMP RISE
HEATER: 20 oF 40 oF 20 oF 40 oF 20 oF 40 oF
10 KW 70 min 140 min 105 min 210 min --- ---
15 KW 47 min 94 min 71 min 142 min 94 min 188 min
30 KW
45 KW
23 min 46 min 35 min 70 min 47 min 94 min
10 min 30 min 20 min 35 min 35 min 40 min
* Based on a 15' ceiling height - lower ceiling height will reduce time required
10 KW, 240V, 1Phase factory pre-wired model with 10 ft. cable & straight blade range plug.
Standard YES Models
Wall Mounted Ceiling Mounted
• Wall / ceiling mount included with unit
• Unit is ready for direct wiring
45 Kilowatt FES Model
• Safety yellow heater enclosure with safety screens on both air intake
and output openings.
• Optional 25’ long SO type cord, ready for plug attachment is
available for each model.
• Long-life nned tubular heating elements.
• Thermostat adjustment 40° to 100° F.
• Two 10” rear wheels and a front locking caster.
• High-limit thermal cutout switch with
manual reset.
• 2200 CFM
• Fan only operation feature
THE ELECTRIC
ALTERNATIVE TO
PROPANE AND
KEROSENE SPACE
HEATERS
• Thermostat adjustment 40° to 100° F.
Manufactured in U.S.A.
Manufactured in U.S.A.
*Plug not included.
UPC MODEL KW BTU's VOLTS PHASE AMPS TEMP RISE WT.
686334
886086 YES-1520-3A 15 51195 208 3 42 45oF 60 lbs.
886185 YES-1524-1A 15 51195 240 1 63 45oF 60 lbs.
886093 YES-1524-3E 15 51195 240 3 36 45oF 60 lbs.
886109 YES-1548-3E 15 51195 480 3 18 45oF 60 lbs.
886123 YES-3048-3A 30 102390 480 3 36 90oF 72 lbs.
UPC#
686334 MODEL KW BTU's VOLTS PHASE AMPS TEMP
RISE WT.
874434 FES-0924-1C 9 30717 240 1 38 25oF 55 lbs.
886000 FES-1024-1CA 10 34130 240 1 42 30oF 60 lbs.
UPC
686334 MODEL KW BTU’s VOLTS PH AMPS TEMP
RISE WT.
872225 FES-4548-3 45 153585 480 3 54.2 70°F 125 lbs.
487405 FES-4560-3 45 153585 600 3 44 70oF 125 lbs.
OPTIONAL 25’ POWER CORD
UPC# 686334 MODEL
316439 SO 4/4
316408 SO 6/4
UPC#
686334 MODEL KW BTU's VOLTS PH AMPS TEMP RISE W T.
886017 FES-1520-3A 15 51195 208 3 42 45oF 65 lbs.
886079 FES-1524-1A 15 51195 240 1 63 45oF 69 lbs.
886024 FES-1524-3E 15 51195 240 3 36 45oF 65 lbs.
886031 FES-1548-3E 15 51195 480 3 18 45oF 65 lbs.
886048 FES-1560-3A 15 51195 600 3 15 45oF 65 lbs.
886055 FES-3048-3A 30 102390 480 3 36 90oF 83 lbs.
886062 FES-3060-3A 30 102390 600 3 29 45oF 65 lbs.
OPTIONAL 25' POWER CORD*
UPC 686334 MODEL
316408 SO 6/4
880530 SO 4/3
316408 SO 6/4
316422 SO 12/4
316408 SO 6/4
316422 SO 12/4
79
188 Series 120 Volt “Milk-house” Style Fan Forced Portable Heater
198 Series 120 Volt Radiant and/or Fan Forced Portable Heater
• 1300W & 1500W heat settings
plus fan only setting
• Temperature control thermostat
• 6’ long - 3 conductor cord
Width: 10”
Height: 16”
Depth: 9-1/2”
• 3-Heat settings:
- 600 Watt radiant
- 900 Watt fan forced
- 1500 Watt radiant & fan forced
• Temperature control thermostat
Width: 11”
Height: 15”
Depth: 12”
483 Series 120 Volt Portable Baseboard Convection Heater
• 1500 Watt convection heater
• Temperature control thermostat
• Manual reset type limit control
• Power on indicator light
• 6’ long - 3 conductor cord
Width: 48”
Height: 5-1/4”
Depth: 7-1/2”
• Dual safety system:
- Tip over switch
- Manual reset type limit control
• 6’ long - 3 conductor cord
• 1 year limited warranty
Manufactured in U.S.A.
“Under-The-Desk” Conned Space Radiant Heat Panel
• Use under desks for personal comfort or
in small areas for freeze protection or
moisture removal.
• Built in stand.
• Temperature control thermostat.
• 6' long - 3 conductor cord
Manufactured in U.S.A.
• Triple safety system:
- Tip over switch
- Automatic reset type limit control
- Thermal cut-off device
178 Series 120 Volt Ceramic Fan Forced Portable Heater
• 850W & 1500W heat settings
plus fan only setting
• Temperature control thermostat
• 6’ long - 3 conductor cord
Width: 11-1/4”
Height: 10”
Depth: 7”
• Double safety system:
- Automatic reset type limit control
- Thermal cut-off device
Width: 22-3/4”
Height: 8”
Depth: 1-3/4”
Note: Photograph is a representation of stocked models. Actual model may vary in appearance.
Standard Models
Standard Models
Standard Models
Standard Models
Standard Models
UPC
686334 MODEL WATTS MAX
BTU’s VOLTS AMPS PHASE WT.
870887 483 TM 1500 5120 120 12.5 1 13 lbs.
UPC#
686334 MODEL WATTS BTU’s VOLTS PHASE WT.
450881 170-TS 170 580 120 1 9 lbs.
UPC MODEL WATTS MAX
BTU's VOLTS AMPS PHASE WT.
686334
445092 198 TMC 1500 / 900 / 600 5120 120 12.5 / 7.5 / 5 1 9 lbs.
UPC
686334 MODEL WATTS MAX
BTU's VOLTS AMPS PHASE WT.
800419 188 TASA 1500 /
1300 5120 120 12.5 / 10.8 1 9 lbs.
UPC MODEL WATTS MAX BTU's VOLTS AMPS PHASE WT.
686334
445931 178 TMC 1500 / 950 5120 120 12.5 / 7.1 1 8 lbs.
80
30 AMP Plug
NEMA #6-30P
20 AMP Plug
NEMA #6-20P
30 AMP Plug
NEMA #6-30P
20 AMP Plug
NEMA #6-20P
30 AMP Plug
NEMA #6-30P
20 AMP Plug
NEMA #6-20P
30 AMP Plug
NEMA #6-30P
20 AMP Plug
NEMA #6-20P
474 Series 240 Volt Dual Heat Fan Forced Portable Heater
• 2000W & 4000W heat settings
• Temperature control thermostat
• Manual reset type limit control
• 6’ long - 3 conductor cord
Width: 16”
Height: 16”
Depth: 8-1/2”
ICH Series 240/208 Volt Construction Site/Utility Fan Forced Portable Heater
680 Series “Bulldog” 240/208 Volt Fan Forced Portable Unit Heater
Swivel base allows unit to be wall, oor, or
ceiling mounted.
Width: 10 5/8”
Height: 12 3/4”
Depth: 10”
• Operates on 240V or 208V
• Finned steel tubular heating element
• Internal manual reset thermal cut-out
• 6’ long cord with molded plug
• Temperature control thermostat with 35°F to 85°F range
• 10’ air throw - 262 CFM
Width: 13 1/2”
Height: 17 1/2”
Depth: 11 1/2”
* HF684TC UL listed only
• Operates on 240V or 208V
• Steel tubular heating element
• 43°F air heat rise
• Internal overheat thermostat
• Temperature control thermostat
• 6’ long cordset
5800 Series Garage/Workshop 240/208 Volt Fan Forced Portable Heater
• Up to 4800 Watts of heating comfort for
garage or utility room applications
• 4000 Watts available for smaller areas.
• Built in bi-metal double pole
thermostat - 50° to 90° range.
• Steel tubular heating element
• Wall/Ceiling bracket included
• Manual reset standard
• Power on and overheat pilot lights
ITEM WIDTH HEIGHT DEPTH
Heater 10.625 11” 9.625”
Bracket 2.5” 10” 14.0”
HF684TC HF685TC,
HF686TC
UPC#
686334 MODEL WATTS MAX
BTU's VOLTS AMPS PHASE W T.
450874 ICH-240C 4000 / 3000 13648 240 / 208 16.7 / 14.4 1 15 lbs.
UPC#
686334 MODEL WATTS MAX
BTU's VOLTS PHASE AMPS TEMP
RISE WT.
446280 *HF684TC 4000/3000 13652/10239 240/208 1 16.7/14.5 48 oF 20 lbs
446297 HF685TC 4800/3600 16384/12288 240/208 1 20.0/17.4 58oF 20 lbs.
446303 HF686TC 5600/4200 19107/14330 240/208 1 23.4/20.2 75 oF 20 lbs.
683500 A1560 OPTIONAL WALL CEILING BRACKET FOR HF680 & ICH 240c SERIES
HEATERS
UPC#
686334 MODEL WATTS MAX
BTU's VOLTS AMPS PHASE W T.
446181 H474 TMC 2000 / 4000 13652 240 8.3 / 16.6 1 20 lbs.
UPC#
686334 MODEL WATTS MAX
BTU's VOLTS AMPS PHASE PLUG
TYPE WT.
(LBS)
503402 HF5840TC 4000/3000 13652 240 / 208 16.6 / 14.4 120 Amp 17
503396 HF5848TC 4800/3600 15086 20 / 17.3 30 Amp
81
Specialty Heaters
RPH Series Pump House Convection Specialty Heater
• Provides protection against freezing for pump houses, utility
rooms, relay stations, construction sheds, etc.
• Aluminum nned heating element
• Powder coated epoxy steel case
• Automatic temperature control thermostat with a 35oF to 65oF
range.
• Dimension 20” x 5-1/2” x 4”
FH Series In-Floor Fan Forced Specialty Heater
• Powder coated 20 gauge steel case
• 14 gauge grill
• Steel spiral nned heating element
• Auto reset thermal cut out with audible alarm.
• Floor opening: 14-1/8” x 7-1/4” x 7-3/8”
• Grill dimensions: 15-13/16” x 8-13/16”
• Fits into softs, stair risers or under utility cabinets
• Finned steel heating element.
• Manual reset thermal cut-out
• Recessed opening: 22-3/8” x 3-5/8” x 11-1/2”
• Grill dimensions: 23-7/8 x 3-5/16
TSH Series Fan Forced Kickspace Specialty Heater
Manufactured in U.S.A.
Manufactured in U.S.A.
Manufactured in U.S.A.
Standard Models
Standard Models
Standard Models
UPC#
686334 MODEL WATT S BTU’s VOLTS AMPS WT.
999083 RPH1-5A 500 1706 120 4.2 5 lbs.
999090 RPH2-5A 500 1706 240 2.1 5 lbs.
International Models
984263 RPH22-5Ai 500 1706 220 2.3 5
984270 RPH2-5Ai 240 2.1
UPC#
686334 MODEL WATT S BTU’s VOLTS AMPS WT.
378239 FH15
750 2560 120 6.25
15 lbs1500 5120 120 12.5
1500/1125 5120 / 3840 240/208 6.25/5.41
OPTIONAL FIELD INSTALLED THERMOSTATS
378277 FH1T Single Pole Integral Thermostat Kit 1lb
UPC#
686334 MODEL WATT S BTU’s VOLTS AMPS WT.
381802 TSH20J
1500 / 1000 5120 / 3412 120 12.5 / 8.4
16 lbs
1500 / 750 5120 / 2560 208 7.2 / 3.6
2000 / 1000 6284 / 3412 240 8.4 / 4.2
970174 TSH20JW Above Model with White Grill
OPTIONAL FIELD INSTALLED THERMOSTATS
378376 TSH1TX Single Pole Integral Thermostat Kit 1lb
378383 TSH2TX Double Pole Integral Thermostat Kit 1lb
82 Product Specications
CABINET: Shall be constructed of 20 gauge rigid steel with baked on epoxy powder coat paint for du-
rability.
DISCHARGE VANES: Shall extend the entire width of the unit and be adjustable for optimum perfor-
mance of air ow.
BLOWERS: Shall be forward curved centrifugal type, DWDI with corrosion resistance scroll
and wheel.
MOTORS: Shall be heavy duty, PSC, direct drive high efciency and designed for use with
SCR controllers. Motors shall be permanently lubricated for long life and have thermal over
load protection. Motor shall
have double insulation pro-
tection for quieter operation.
Quick disconnects shall be
supplied to accommodate
easy installation and service
of motor.
SCR SPEED CONTROL-
LER: Supplied on all units
compatible with the motor
with low end adjustment for
air volume control and sav-
ings in power consumption.
ELECTRIC HEAT (OPTION-
AL): Electric heater available
as eld installed option. Elec-
tric heater shall be steel sheath
element with helical wound
steel ns for maximum heat
transfer and safety.
Air Curtain with Heater
Module
NOTE: All heating sections
are constructed of totally
enclosed n tubular ele-
ments for safety and longer
operating life. With heat-
ing section installed, unit
becomes a 24 Volt control
unit and can utilize a low
voltage thermostat for con-
trol of heating.
NOTE: For 72” through
120” units, order multiple
heater modules corre-
sponding to the actual air
curtain models
CF & CFH Series Variable Speed Air Curtains
Manufactured in U.S.A.
SD Series - Setback on Demand Thermostat
FULLY AUTOMATIC: All the savings without any of the hassles of a programmable ther-
mostat. Once installed, everything is automatic. When people are present it automatically
controls to the comfort setting. When they leave, it automatically returns to the economy
setting.
SMART COMFORT: The SD thermostat learns your schedule so you arrive to a comfortable
temperature. Holidays are no problem. When no-one arrives, it automatically returns to the
economy setting.
AUTO-CHANGEOVER: Our Auto-Changeover doesn’t limit your comfort
settings. We incorporate an adjustable deadband to protect your equipment while maintaining
comfort. Factory set at 1 degree, but adjustable from 1-5 degrees.
ONE MODEL WORKS WITH ALMOST ANY LOW VOLTAGE SYSTEM.: The SD ther-
mostat works with low voltage systems up to 4 stages of heat, 4 stages of cool, or any com-
bination up to a total of 4 stages including Heat Pumps.
Patent Pending
EXAMPLE Use the example shown (left) to order unit with heat section
by specication
Model # Unit Width KW Volts Phase
CFHTR 36 10.0 208 3
| | | | |
MODEL HEATER
WIDTH KW VOLTS
PHASE
HEATER
AMPS
MINIMUM CIRCUIT
AMPS
MAXIMUM
FUSE AMPS
BTUH 75°C WIRE
AWG
CFHTR
36, 48, or 60 Inch Width
NOTE: 12KW MAXIMUM ON 36” WIDTH UNITS
3
208
3
8.3 10.4 15
10,239
14
240 7.2 9.0 15 14
480 3.6 4.5 15 14
277
1
10.8 13.5 15 14
208 14.4 18.0 20 12
240 12.5 15.6 20 12
5
208
3
13.8 17.25 20
17,075
12
240 12.0 15.0 20 12
480 6.0 7.5 15 14
277
1
18.0 22.5 25 10
208 24.0 30.0 35 8
240 20.8 26.6 30 10
7.5
208
3
20.8 26.0 30
25,597
10
240 18.0 22.5 25 10
480 9.0 11.3 15 14
277
1
27.0 33.8 40 8
208 36.0 45.0 50 6
240 31.2 39.0 45 8
10
208
3
27.7 34.4 40
34,130
8
240 24.0 30.1 35 8
480 12.0 15.0 20 12
277 136.1 45.1 50 6
240 41.6 52.0 60 6
12
208
3
33.3 41.6 45
40,956
8
240 28.8 36.0 40 8
480 14.4 18.0 20 12
277 1 43.3 54.1 60 6
15
208
3
41.6 52.0 60
51,195
6
240 36.0 36.0 55 6
480 18.0 18.0 30 10
UPC
686334
SIZE
(in) MODEL FT. / MIN.
HI - LOW
NOZZLE
CFM VOLTS RPM
HI - LOW
AMPS
HI - LOW
WATTS
HI - LOW
WT.
(lbs)
STANDARD UNITS: 1/2 HP MODELS - UP TO 10’ HIGH DOORWAYS - WITHOUT HEAT SECTION
671200 36 CF36 3288/455 2672/333
120
1659/620 3.9/3.4 472/154 74
671217 48 CF48 4168/786 4515/766 1606/583 4.4/3.6 519/189 82
671224 60 CF60 4168/764 6544/931 1636/562 4.4/3.8 509/199 90
72 2 EA: CF36 3288/455 5344/666 1659/620 7.8/6.8 944/308 148
96 2 EA: CF48 4168/786 9030/1532 1606/583 8.8/7.2 1038/378 164
108 3 EA: CF36 3288/455 8016/999 1659/620 11.7/10.2 1416/462 222
120 1 EA: CF48 4168/786 9859/1432 1606/583 12.2/10.4 1982/497 230
2 EA:CF36 2672/333 1659/620
HEAVY DUTY UNITS: 3/4 HP MODELS - UP TO 12’ HIGH DOORWAYS - WITHOUT HEAT SECTION
671231 36 CFHD36 3288/1120 2672/819
120
1689/603 4.4/4.3 603/192 77
671248 48 CFHD48 4256/929 4611/906 1662/500 5.9/4.8 586/168 85
671255 60 CFHD60 4256/924 5763/1126 1652/509 5.2/4.4 708/172 93
72 2 EA: CFHD36 3288/1120 5344/1638 1689/603 8.8/8.6 1206/384 154
96 2 EA: CFHD48 4256/929 9222/1812 1662/500 11.8/9.6 1172/336 170
108 3 EA: CFHD36 3288/1120 8016/2457 1689/603 13.2/12.9 1809/576 231
120 1 EA: CFHD48 4256/929 9955/2544 1662/500 14.7/13.4 2981/552 239
2 EA: CFHD36 3288/1120 1689/603
UPC#
686334 MODEL COLOR TYPE
523646 SDHW1001 White Hardwire
83
Thermostats & Controls
• White or Ivory
• Single pole and double pole
• Heat Only
• DP models include positive off
• 22 Amps, 277 Volts AC
• Single pole and double pole
• Heat only, cool only, & heat or cool
• DP models include positive off
• Celsius and Fahrenheit temperature
scale
• Optional Thermometer
• 22 Amps, 277 Volts AC
• SPDT & DPDT Models
• Heat or cool compatible
• Celsius and Fahrenheit temperature scale
• Bi-Metal or capillary sensor
• Snap action switch
• Casting tapered top and bottom for 3/4” conduit
• 1/2” thick cast Aluminum housing
• Dimension 5-3/4” x 6-3/8” x 5.57”
Features
Features
Features
2000 Series - Line Voltage
ET Series - Line Voltage
EPET Series and HLT Series Hazardous Location
Motor Rating (full load): 3/4 HP @ 125V, 1-1/2 HP @250V
Pilot Duty Rating 125VA @ 24VAC
NEMA Class Seven Div. 1 Approved
Class I Group C & D, Class II Group E, F, & G
Not rated for Group B
UPC#
686334 MODEL DESCRIPTION LOAD RATINGS RANGE
538077 EPETD8D DPDT - Bi-Metal 22A @120-277VAC 50-90oF
538107 EPETD8S SPDT - Bi-Metal 22A @120-277VAC 50-90oF
528078 EPETP8D DPDT - Bi-Metal 22A @120-480VAC 50-90oF
528061 EPETP8S SPDT - Bi-Metal 22A @120-480VAC 50-90oF
523158 HLT-1 SPDT - Capillary 22A @120-277VAC 40-110oF
523165 HLT-2 DPDT - Capillary 22A @120-277VAC 40-110oF
Master ctn: 4 pcs, 24 lbs (varies slightly by model), 16” x 14.5” x 6”
EPET Series incorporate plastic knob & Bi-Metal Sensor housing.
HLT Series incorporates screwdriver temperature adjustment slot and all metal housing. External
bulb and capillary sensor.
UPC#
686334 MODEL COLOR DESCRIPTION
502849 S2022H10AA White
Single Pole with leads, 22 Amp
502436 S2022H10AB Ivory
502856 D2022H10BA White
Double pole with leads, 22 Amp
502443 D2022H10BB Ivory
502917 S2025H10AA White Single Pole with leads, 25 Amp
502924 D2025H10BA White Double pole with leads, 25 Amp
UPC #
686334 MODEL DESCRIPTION
538725 AET5DWS Double Pole 22 Amp, 120-277V with leads, Anticipator
538732 AET5SWS Single Pole 22 Amp, 120-277V with leads, Anticipator
538886 ET5DS Double Pole 22 Amp, 120-277V, Heat Only
538749 ET5D4S Double Pole 22 Amp, 120-277V, 35-75oF Temp Range
538756 ET5DTS Double Pole 22 Amp, 120-277V, with Thermometer, Heat Only
538763 ET5DWS Double Pole 22 Amp, 120-277V, Heat Only with Leads
538770 ET5MS Heat Only, 2 Stage
538787 ET5SS Single Pole 22 Amp, 120-277V, Heat Only
538794 ET5S4S Single Pole 22 Amp, 120-277V, 35-75oF Temp Range
538800 ET5SRS Single Pole 22 Amp, Cooling Only
538893 ET5SRTS Single Pole Cool with Thermometer
538817 ET5STS Single Pole 22 Amp, Heat Only with Thermometer
538824 ET5SWS Single Pole 22 Amp, Heat Only with Leads
538831 ETD5MS Double Throw, 2 Stage Heat, 1 Stage Cool
538848 ETD5MTS 2 Heat, 1 Cool with Thermometer
538855 ETD5SS Single Pole Double Throw Heat/Cool
538862 ETD5STS Single Pole Double Throw Heat/Cool with Thermometer
84
Thermostats & Controls
TW Series
• Single and double pole models
• Wire leads
• Tamper resistant
Features Load Rating
• 22 Amps resistive @ 120 VAC
• 18 Amps resistive @ 277 VAC
Washdown Series
• Single and double pole models
• Rain tight NEMA 4X rating
Features
• Stainless steel hardware
• Coil capillary temperature sensor
Industrial Series
• Coil capillary (CKT) models
• Bi-Metal models (KT)
• Rugged steel case
• SPST & SDPT models
• Hard wired models rated for
22A resistive @125-250 VAC
• Corded models rated for 13A
resistive @125VAC
Features
L Series
• 6’ or 8’ Capillary
• Rugged steel cage
• SPDT for Heat or Cool
• 25A resistive
• Rated differential of 6°F
Features
UPC#
686334 MODEL DESCRIPTION TEMPERATURE SCALE
502009 TW145 SP, Beige with Leads Tamper Resistant
502016 TW146 DP, Beige with Leads Tamper Resistant
Master Carton: 25 Pcs, 12 lbs. (varies slightly by model), 16” x 14” x 5.5”
UPC#
686334 MODEL DESCRIPTION TEMPERATURE SCALE
523424 TW155A SP, Rain tight 40-110oF
523431 TW255A DP, Rain tight 40-110oF
22 Amps @ 120/250/277 VAC, 5” x 5” x3” Case
UPC#
686334 MODEL DESCRIPTION RANGE CONNECTIONS SCALE
534048 CKTD110 SPDT Heat or Cool 40 - 110oF Wire Leads F
534086 KT110 SPST Heat Only -10 - 100oF Wire Leads C & F
534109 KT121 SPST Heat Only -10 - 100oF 6’ Cord/Plug C & F
534178 KTD110 SPDT Heat or Cool -10 - 100oF Wire Leads C & F
534369 KTO110 SPST Cool Only -10 - 100oF Wire Leads C & F
534215 KTO121 SPST Cool Only -10 - 100oF 6’ Cord/Plug C & F
Master Carton: 13.75” x 14” x 9”, Qty 9-12, 14lbs.-16lbs. depending on model
UPC#
686334 MODEL DESCRIPTION RANGE CAPILLARY SCALE
534260 L06Y-01 SPDT Heat or Cool 0 - 90oF 6’ F
534277 L08Y-01 SPDT Heat or Cool 0 - 90oF 8’ F
Master Carton: 13.75” x 14” x 9”, 12 Pcs, 18lbs.
85
Features
Thermostats & Controls
Electromechanical De-Humidistat
Features
• 50VA @ 24VAC - 240VAC
• 10% - 60% relative humidity range
• 4.4 amp @ 120VAC
• 2.2 amp @ 240VAC
Honeywell Line Voltage Thermostats
• Heat only thermostats
• Accurate temperature control
Features
• 22 Amp resistive for mechanical models
T4398A 1021
Precision Mechanical
TL8230A 1003
Electronic Programmable
Electromechanical Humidistat
Features
• 50VA @ 24VAC - 240VAC
• 10% - 60% relative humidity range
• 4.4 amp @ 120VAC
• 2.2 amp @ 240VAC
• Heat only thermostats
• Accurate temperature control
Features
Standard Models
Standard Models
Standard Models
Standard Models
• 16 Amp resistive for electronic models
• Energy Star compliant.
Wireless RF Interface Series
• Heat only, Cool only
• 4 wire Heat/Cool
• Standard 2 stage Heat/ 1 Stage Cool Heat Pumps
• Multistage heating and/or cooling equipment
• Works with most low voltage
thermostats
• Temp Range: 50-130 F
• Max Operating Range: 50 Feet
RFT-1
RFT-1 shown with
UT thermostat
RFR-5
UPC#
686334 MODEL DESCRIPTION
589147 H1D1AA Dehumidistat/Electromechanical
UPC#
686334 MODEL VOLTAGE DIMENSIONS DESCRIPTION
503303 T4398A
1021 120-240 2.875”x4.375”x2.00D
Precision Electric Heating. SPST,
50-80 OF,
22 Amp @ 120-240V 19 Amp @ 277V
UPC#
686334 MODEL DESCRIPTION
523370 H46D1214 Humidistat/Electromechanical
UPC#
686334 MODEL VOLTAGE DIMENSIONS DESCRIPTION
503365 TL8230A 1003 240/208 2.70”x4.90”x.90D Electronic Programmable Line
Voltage DPST, 15 Amp, 40-86 OF
UPC#
686334 MODEL DESCRIPTION VOLTAGE CONNECTIONS
523554 RFT-1 RF Thermostat Transmitter
Dim: 4” x 5” x .875” 2-AAA Batteries 6 Wires
523561 RFR-5 RF Relay Interface
Dim: 4.5” x 6” x 1.25” 24 VAC R-C-R1
1-2-3-4-5
523578 RFKit-5 RFT-1 & RFR-5 Package 2 AAA
24 VAC
R-C-R1
1-2-3-4-5
86
Thermostats & Controls
Round - Low Voltage
Features
• Does not contain Mercury
• Dimensions 3-11/16” diameter
• Heat only for 24V heating systems
• White color • Temperature range - 50o - 90oF
Low Voltage Programmable Thermostats
Features
• 7 Day, 4 Settings Per Day
• Pre-Programmed or Custom Settings
• Control Accuracy +/- 1oF of Setpoint Temp
• Backlit Display, Energy Star Compliant
TH147-P
TH115-A-024T
Standard Models
Standard Models
Features
• 7 Day, 4 Settings Per Day
• Pre-Programmed or Custom Settings
• Control Accuracy +/- 1oF of Setpoint Temp
• Backlit Display, Energy Star Compliant
Standard Models
2 Stage Low Voltage Thermostat
Standard Models
Features
• 24V single or 2 stage heat and cool
• Gas, oil, or electric with air conditioning.
• Heat only, Heat only with fan, Cool only.
• Battery only, common wire only or common wire with battery
backup.
• System settings - Heat, Off, Cool, Auto, Emergency Heat.
• Temperature range - Heat 40-90oF, Cool 50-99oF.
• Dimensions: 3-9/16” H x 5-13/16” W x 1-1/2” D
TW123
UPC#
686334 MODEL DESCRIPTION VOLTAGE MAX AMP
260008 A6176 Heat/Cool 24 VAC 1.0
UPC#
686334 MODEL DESCRIPTION
523400 TH115-A-024T
Heat Only
Temp Range:40-86OF
Dims:4.89”H x 2.79”W x .91”D
UPC#
686334 MODEL DESCRIPTION
523585 TH147-P
7 Day, 4 Settings per Day, Heating/Cooling, 1 Stage Heat/Cool
Temp Range Heat:41-82OF, Cool:59-95OF
Dims: 5”W x 3”H x 1”D,
UPC#
686334 MODEL VOLTAGE TEMP
RANGE
MAX
AMP
691116 TW123 / TH5220D 750MV - 2DV 40-90 Heat
50-99 Cool 1.0
87
Thermostats & Controls
RK Series - Low Voltage
Features
• Fahrenheit and Celsius temperature
scales
• 2-3oF rated differential
• Heat only models
• Positive off
Low Voltage Relays
Features
• Built-In transformer
• 45 second average time delay
• Temperature range - 50o - 90oF
UT Series - Low Voltage
Features
• Fahrenheit and Celsius temperature
scales
• 2-3oF rated differential
• Anticipator (except UT9001)
• Vertical or horizontal mounting
• Long life sealed contacts
• Does not contain Mercury
• Leveling not required
Standard Models
Standard Models
Standard Models
Features
• 8 tumbler locks
TG Series Thermostat Guards
Standard Models
• Snap action switch
• 1/2” male conduit spud
• Does not contain Mercury
• Leveling not required
• Long life sealed contacts
Two switch unit shown.
UPC#
686334 MODEL DESCRIPTION VOLTAGE TERMINALS SWITCHES
523059 UT1001 Heat Only 24VAC or MV R &W None
523066 UT3001 Cool Only 24 VAC R, Y & G Cool/Off Fan/Auto
523134 UT6001 Deadband 24 VAC R, W & Y None
523073 UT8001 Heat/Cool 24 VAC RC, RH, W, Y, & G Heat/Off/Cool Fan/Auto
523110 UT9001 Heat Only Millivolt R & W None
Master Carton: 50 pcs, 17 lbs, 19” x 11.5” x 9”
UPC #
686334 MODEL DESCRIPTION VOLTAGE RANGE ANTICIPATOR
526012 RK120EAA Heat Only 24VAC or MV 50o-90oFYe s
526203 RK124EAA Heat Only 24VAC or MV 35o-75oFYe s
526050 RK130EAA Heat Only Millivolt 50o-90oF No
526326 RK134EAA Heat Only Millivolt 35o-75oF No
526142 RKWP1AA Wall Plate NA NA NA
Master Carton: 100 Pcs, 24 lbs, 16.5” x 15” x 8”
UPC#
686334 MODEL PRIMARY
VOLTAGE DESCRIPTION
260039 24A05A-1 120 Volts
Single Switch, single throw with In-Built Transformer for remote
mounting or in a factory provided optional enclosure
260046 24A05E-1 208 Volts
260053 24A01G-3 240 Volts
260107 24A06G-1 240 Volts Two switch, single throw with In-Built Transformer, 25 Amps per
switch
UPC#
686334 MODEL DESCRIPTION
589123 TG1 Plastic Stat Guard/ 6.25” x 3.625” x 3.25” Opening
589109 TG1B Metal Stat Guard/ 5.25” x 4.625” x 3” Opening
589130 TG2 Plastic Stat Guard/ 5.25” x 4.625” x 3.25” Opening
589161 TG2B Metal Stat Guard/ 6.25” x 3.625” x 3.25” Opening
589116 TG3 Plastic Stat Guard/ 8.125” x 4.625” x 3.625” Opening
589178 TG3B Metal Stat Guard/ 6.75” x 4.50” x 3.50” Opening
523615 TG4 Plastic Stat Guard / 3.50” x 3.937” x 1.75” Opening
523622 TG5 Plastic Stat Guard / 5” x 3.31” x 1.75” Opening
523639 TG6 Plastic Stat Guard / 5.75” x 4.625” x 1.75” Opening
88
Thermal Area Treatment Heaters
APPLICATIONS:
• The "TAT" series is designed to heat small and mid-sized rooms up to 150 oF. This provides effective portable
heating to areas infected with insects. It kills adult insects and will dehydrate larvae and eggs, making them unable
to hatch. Although chemical sprays only target adult insects, they can be used before utilizing the "TAT" system in
order to kill the adult insects.
• The system is designed to bring the temperature up to 150 oF in one hour or less, if all preliminary requirements are
met.
• The "TAT" system may be used for water remediation, as well, in combination with adequate ventilation. Specic
models for water remediation are also available.
TAT BASE UNIT:
• Heavy duty stainless steel spiral n heating elements
• High temperature, ball bearing 1/3 HP - 1075 RPM blower motor
• Forward curved centrifugal blower-900 CFM of air output
• Safety devices include airow switch, disconnect switch, automatic limit control and manual reset limit control for
secondary protection
• 50 Amp unit may be linked to a 30 Amp unit to provide heating for larger spaces.
• Timer/Temp controller may be used to control both units but must use the 50 Amp base unit as the master.
SUPPLEMENTAL TAT CONVECTORS
• 3 convectors are an integral part of each TAT system
• 120 Volt, 15 Amp (Standard wall plug) - 5120 BTU size
• Supplied with 25' prewired cable that connects them to the TAT base unit control section with a three pin connector
• If used in front of windows or large glass doors, they will reduce heat loss and provide more even heating
TIMER/TEMPERATURE CONTROL UNIT
• Timer/Temp Controller is an integral part of the TAT system
• 24 Volt control device that controls the heat output of the TAT base unit and up to three TAT convectors for an
operating range of 120 - 150 oF and for a time period of 1 -10 hours after the preset temperature is reached
• Supplied with a 25' prewired cable that connects to the TAT base unit control section using a four pin connector
• Mounts on Door outside the area being treated.
• LED lights will indicate when treatment is complete
Product Specications
• Heavy duty industrial construction
• Forward curved centrifugal blower
• High Temperature ball bearing motor
• Optional replaceable lter
• Single point power connection
• 24 volt control
• Heavy duty spiral nned elements constructed of stainless steel
• Safety devices include airow switch, automatic limit control and manual reset limit control for secondary protection
• Disconnect switch and Unit Mounted Thermostat with range of up to 120 to 150 oF
• The “TAT” series is sold as a system that includes the base unit, three supplemental units and the remote
timer/ temperature control (supplemental units may be purchased separately if necessary)
Product Features
Sizing formula for TAT Series heaters: 50
Watts of heat per square foot of heated space
or 50W/sq ft.
Example: An 800 square foot structure will
require 40,000 Watts of heat to obtain 150
degrees of prolonged heat to be effective.
(800 sq ft x 50 Watts per square foot = 40,000
Watts of heat or 40KW of heat)
89
5"
7"
3"
8.75"
48"
CORD LENGTH: 6'10"
16AWG USASI HPN CORD
CORD LENGTH: 25'
18AWG SHIELDED CABLE
H
L
W
HANDLE ADDS 6" TO L"
10.625"
5"
7"
3"
8.75"
48"
CORD LENGTH: 6'10"
16AWG USASI HPN CORD
CORD LENGTH: 25'
18AWG SHIELDED CABLE
H
L
W
HANDLE ADDS 6" TO L"
10.625"
H
LW
H
L
W
H
LW
H
L
W
Thermal Area Treatment Heaters
Standard Models
Product Dimensions
MODEL DIMENSIONS WT. (LBS)
LENGTH WIDTH HEIGHT
TAT-8-240-1 39” 26.5” 18” 180
TAT-5-240-1 39” 26.5” 18” 180
TAT-20-480-3 39” 30.5 18” 234
TAT-1-120-1 48” 8.5” 9.5” 23
Remote Timer 11” 3” 4.5” 5
TAT 30, 45 37” 24” 39” 115/125
TAT24-FAN-120V-1 10.5” 26” 26” 30
*208 Volt models do not have a cord supplied
Accessories
• Single speed
• Head tilts 360o
• Coated steel guards
• SJT type 3 conductor
• Steel hub / Aluminum blades
• Meets OSHA standards
TAT-24-FAN-120V-1
TAT 30-45
• Safety yellow heater enclosure with safety screens
on both air intake and output openings.
• Optional 25’ long SO type cord, ready for plug
attachment is available for each model.
• Long-life nned tubular heating elements.
• Thermostat adjustment 120° to 150° F.
• Two 10” rear wheels and a front locking caster.
• High-limit thermal cutout switch with manual reset.
• 2200 CFM
• Fan only operation feature
UPC#
686334
STYLE MODEL
NUMBER
BASE
UNIT
KW
BASEBOARD
PERIMETER
HEATER KW
TOTAL
SYSTEM
KW
BASE
UNIT
VOLTS
BASEBOARD
PERIMETER
HEATER
VOLTS
PHASE
BASE
UNIT
AMP
BASEBOARD
PERIMETER
AMP-EACH
CIRCUIT (3)
PLUG TYPE
BASE UNIT PERIMETER
397568 TAT5-240-1/3BB/1T 5.3 1.5 (X3) 9.8 240 120 1 24 12.5 Nema 10-30 Nema 5-15
397629 TAT5-208-1/3BB/1T* 5.3 1.5 (x3) 9.8 208 120 1 27 12.5 ---- Nema 5-15
397551 TAT8-240-1/3BB/1T 8.4 1.5 (X3) 12.9 240 120 1 37 12.5 Nema 14-50 Nema 5-15
397612 TAT8-208-1/3BB/1T* 8.4 1.5 (x3) 12.9 208 120 1 42 12.5 ---- Nema 5-15
397520 TAT20-480-3/3BB/1T 20 1.5 (X3) 24.5 480 120 3 26 12.5 Nema L16-30 Nema 5-15
397582 TAT-ILC-25 25’ Shielded Cable
UPC#
686334 MODEL DESCRIPTION HP CFM / RPM MAX AMPS VOLTS WT (LBS)
397636 TAT-24-FAN-120V-1 Thermal Area Treatment Floor Fan 1/3 5000/1160 3.1 120 30
UPC#
686334 MODEL DESCRIPTION KW BTU VOLTS PHASE AMPS TEMP RISE WT (LBS)
397834 TAT-30 30KW Salamander 30 102390 480 3 36 43 115
397841 TAT-45 45KW Salamander 45 153585 480 3 54.2 70 125
90
Move dryer,
connect 30 Amp unit
to 30 Amp dryer power
supply.
Seal all exterior
windows and doors
before extermination
process begins.
Move
range/electric
stove, connect
50 Amp unit to
50 Amp range
power supply.
Washer
Dryer
30 Amp Power Supply
30
AMP
TAT Base
Unit
Stove/Range
50
AMP
TAT Base
Unit
Heater Line 1
Heater Line 2
Heater Line 3
Heater Line 1
Heater Line 3
Heater Line 2
Timer Control Line
Timer Control
Unit
50 Amp Power Supply
Master/Slave Unit Control Tether.
Use only if two systems are used together
Diagram is for demonstrative purposes only and does not represent any actual structure or living environment. Two units may not be required for all
situations, exterior climate, structure insulation, electrical service, and square footage all factor into effective treatment with this system.
Thermal Area Treatment Heaters
How It Works:
91
Hotpod™ Supplemental Duct Mounted Heating System
• Use to heat cold rooms or additions without upgrading
central system
•
Fan only operation for increased cfm output for A/C
cycles
• 6" 1000/500 Watt and 8" 1440/720 Watt models
available
• Two stage operation
• 120V corded and hard wire models available
• 10' Cord length on corded models
• Zero clearance for all models
• All models include UT8003 low voltage thermostat
• Optional wireless thermostat
• Silent boot option available for rigid duct applications
HotPod - Features
Standard HotPod Models
Multi-Pak Models - Includes 4 Hotpods
Note: Multi-Pak specications (watts, volts, etc) are for each individual hotpod in the pack excluding weight.
6” Hotpod
8” Hotpod
Note: Silent Boot can only be used with rigid duct work
Patented
Patent No. 8,285,127
*includes 1 HotPod display
Standard Silent Booster Models
6” Silent Booster
8” Silent Booster
Silent Booster - Features
• 120V corded and hardwire models available
• Adds 120 CFM Boost to duct heating or ventilation
applications
• Can utilize optional TPI SilentBoot™ for whisper quiet
operation in rigid duct application.
• 14” of duct, 4’ from register is all that is needed for
installation
• Optional wireless thermostat can be utilized to control
Silent Booster™ to increase room comfort
Silent Booster™ Supplemental Duct Mounted Boosting System
UPC#
686334 MODEL DESCRIPTION WATT S VOLTS MIN.CIRC.
SIZE (AMP)
TEMP
RISE (F) WT RPM CFM NEMA
PLUG
DIMENSION
L X W X H
290074 HP6-1000120-2T 6” INLET, HARDWIRE 1000/500 120 8.33 26 4 1500 130 NA 10 1/2 x 8 1/2 x 6
290043 HP6-1000120-2CT 6” INLET, WITH CORD SET 1000/500 120 8.33 26 4 1500 130 5-15P 10 1/2 x 8 1/2 x 6
290081 HP8-1440120-2T 8” INLET, HARDWIRE 1440/720 120 12.6 23 6 1500 210 NA 11 x 10 1/2 x 8
290067 HP8-1440120-2CT 8” INLET, WITH CORD SET 1440/720 120 12.6 23 6 1500 210 5-15P 11 x 10 1/2 x 8
UPC#
686334 MODEL DESCRIPTION WAT T S VOLTS MIN.CIRC.
SIZE (AMP)
TEMP
RISE
(F)
WT.
LBS RPM CFM NEMA
PLUG
DIMENSION
L X W X H
290036 HP6-1000120-2T 4 PACK 6” INLET, HARDWIRE 1000/500 120 8.33 26 16 1500 130 NA 10 1/2 x 17 x 12
290111 HP6-1000120-2CT
4 PACK 6” INLET, WITH CORD SET
1000/500 120 8.33 26 16 1500 130 5-15P 10 1/2 x 17 x 12
290050 HP8-1440120-2T 4 PACK 8” INLET, HARDWIRE 1440/720 120 12.6 23 25 1500 210 NA 10 1/2 x 20 x 16
290128 HP8-1440120-2CT
4 PACK 8” INLET, WITH CORD SET
1440/720 120 12.6 23 25 1500 210 5-15P 10 1/2 x 20 x 16
290333 HP6H-12PK* 12 PACK 6” INLET, HARDWIRE 1000/500 120 8.33 26 58 1500 130 NA 21 x 14 1/2 x 43
290340 HP6C-12PK*
12 PACK 6” INLET, WITH CORD SET
1000/500 120 8.33 26 58 1500 130 5-15P 21 x 14 1/2 x 43
290357 HP8H-12PK* 12 PACK 8” INLET, HARDWIRE 1440/720 120 12.6 23 82 1500 210 NA 27 1/4 x 14 1/2 x 52
290364 HP8C-12PK*
12 PACK 8” INLET, WITH CORD SET
1440/720 120 12.6 23 82 1500 210 5-15P 27 1/4 x 14 1/2 x 52
UPC#
686334 MODEL DESCRIPTION VOLTS MIN.CIRC.
SIZE (AMP) WT RPM CFM NEMA
PLUG
DIMENSION
L X W X H
290371 SB6-120-T 6” SILET BOOSTER (Hardwire) 120 15 4 1500 130 NA 10 1/2 x 8 1/2 x 6
290388 SB6-120-CT 6” SILENT BOOSTER (w/Cord Set) 120 15 4 1500 130 5-15P 10 1/2 x 8 1/2 x 6
290395 SB8-120-T 8” SILET BOOSTER (Hardwire) 120 15 4 1500 210 NA 11 x 10 1/2 x 8
290401 SB8-120-CT 8” SILENT BOOSTER (w/Cord Set) 120 15 4 1500 210 5-15P 11 x 10 1/2 x 8
92
• Can be used with existing systems for fresh air intake
• Includes replaceable lter
• All units include duct stat and disconnect switch
• Available with 6" inlet and outlet only
Hotpod Accessories And Thermostat
Silent Boot
RFKIT-5 - Patent Pending
* Can be used with Hotpod models as a noise attenuator
RFT-1
( Shown With UT8003
Thermostat)
RFR-5
Hotpod™ Accessories, Thermostats, Ready-Pack, and MFH Models
• Includes all you need to install a complete Hotpod system
• Ideal for room or ofce additions
• RF Thermostat is standard with our Ready-Pack models, simplifying
installation even further - Eliminates the need for thermostat wiring.
• Same specications for 6” and 8” Hotpod models apply to Ready-Pack
models.
• 6” or 8” Hotpod with RFKIT-5 wireless
thermostat and transmitter
• One outlet and one return air grill
• Two 90 degree elbows
• Flexible duct (12.5’)
• 8" models include 2 reducers - 8” to 6”
What’s IncludedFeatures
Ready-Pack self contained system
Note: does not mount to exsisting duct work.
MFH Series Hotpod - For those LARGER areas
• When the standard Hotpod is not enough
• 240V model has 6’ cord set with a NEMA-6-15P Plug
• Unit contains air ow switch
• Zero inch (0”) clearance installation
• All units are shipped with our UT8003 low voltage thermostat
• All units obtain a 33 degree temperature rise
•
RP models are Ready-Pack models and do not need existing duct work
Features
Standard Models
Fresh Air Make Up Units - Features
Standard Models
Hotpod Ready-Pack Self Contained Systems
UPC#
686334 MODEL DESCRIPTION WT
290098 SB-6* 6” SILENT BOOT 4
290104 SB-8* 8” SILENT BOOT 4
523578 RFKIT-5 WIRELESS TRANSMITTER 6
MODEL DESCRIPTION
HP6-1000120-2TRP 6” INLET, 1000W, 120V, READY-PACK
HP6-1000120-2CTRP 6” INLET, 1000W, 120V, READY-PACK WITH CORDSET
HP8-1440120-2TRP 8” INLET, 1440W, 120V, READY-PACK
HP8-1440120-2CTRP 8” INLET, 1440W, 120V, READY-PACK WITH CORDSET
UPC#
686334 MODEL DESCRIPTION WAT T S VOLTS WT CFM RPM
290135 MFHE-0300-6-EAA 6" INLETS, 1500 W, 120V,2 STAGE THERMOSTAT 1500 120 132 250 1500
290197 MFHE-0300-6-EAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS 1500 120 145 250 1500
290142 MFHE-0300-6-EAAC 6" INLETS, 1500 W, 120V,2 STAGE THERMOSTAT, CORD 1500 120 132 250 1500
290203 MFHE-0300-6-EAACRP UNIT ABOVE WITH FLEX, BOOTS, GRILLS 1500 120 145 250 1500
290173 MFHE-0300-6-HAA 6" INLETS, 2000W, 240V, 2 STAGE THERMOSTAT 2000 240 132 250 1500
290234 MFHE-0300-6-HAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS 2000 240 145 250 1500
290159 MFHE-0300-8-EAA 8" INLETS, 1500W, 120V, 2 STAGE THERMOSTAT 1500 120 135 250 1500
290210 MFHE-0300-8-EAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS 1500 120 148 250 1500
290166 MFHE-0300-8-EAAC 8" INLETS, 1500W, 120V, 2 STAGE THERMOSTAT,CORD 1500 120 135 250 1500
290227 MFHE-0300-8-EAACRP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS 1500 120 148 250 1500
290180 MFHE-0300-8-HAA 8" INLETS, 3000W, 240V, 2 STAGE THERMOSTAT 3000 240 135 250 1500
290241 MFHE-0300-8-HAARP UNIT ABOVE WITH FLEX, BOOTS, GRILLS, REDUCERS 3000 240 148 250 1500
UPC#
686334 MODEL DESCRIPTION CFM RPM
290258 MFHE-0300-6-HAAF2D 6" INLETS, 3000W, 240V, FILTER, DUCT STAT 250 1500
290265 MFHE-0300-6-FAAF2D 6" INLETS, 2000W, 208V, FILTER, DUCT STAT 250 1500
93
HOW TO DESIGNATE A MODEL:
Series Number
Element KW
3KW through 50KW
See model chart for KW options.
Element Voltage
F = 208V H = 240V G = 277V P = 480V
Phase
1 = Single Phase 3 = Three Phase
Control System
Blank = None T = Unit Thermostat
SSR = SSR Control
Motor Voltage
E = 120 G = 277 P = 480
Heater Stages
Blank = One 2 = Two
F 3 E 72 15 2 T
7200 Series Plenum Heater
Product Specications
• 20 gauge galvanized cabinet.
• Variable speed motor, factory set at maximum. Motor speed
can be eld adjusted to increase heat rise.
• Acoustically insulated with 1” berglass.
• Access panels on both sides of cabinet.
• 24 Volt controls.
• Air ow switch.
• Terminal blocks.
• Single point connection.
• Dust tight control enclosure.
• Filter rack on inlet with throw away lter.
• Inlet and outlet screens and duct connection.
• Automatic primary limit control and secondary fuse link.
• Optional wall thermostat, unit thermostat or SSR control
which proportionally regulates heat output.
• Disconnect switch.
Manufactured in U.S.A.
Standard Models
SSR proportional control maximum: 45 Amps
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
UPC#
686334 MODEL KW CFM RANGE VOLTS /
PHASE
TOTAL
AMPS for
MOTOR &
HEATER
STAGE MOTOR
VOLTAGE
FULL LOAD
AMPS for
MOTOR ONLY
MOTOR H.P. WT.
(LBS)
617680 F1G7203
3 70-270
208/1 15.4
1
277 1
1/15 98
606561 H1G7203 240/1 13.5 277 1
606240 G1G7203 277/1 11.83 277 1
606905 F3G7203 208/3 9.32 277 1
617765 H3G7203 240/3 8.21 277 1
617574 P3G7203 480/3 4.6 277 1
617666 F1G7205
5 200-650
208/1 25.13
1
277 1.1
1/6 118
617956 H1G7205 240/1 21.93 277 1.1
606165 G1G7205 277/1 19.15 277 1.1
606424 F3G7205 208/3 14.97
1
277 1.1
617994 H3G7205 240/3 13.12 277 1.1
606110 P3G7205 480/3 7.11 277 1.1
606554 F3E7210
10 500-1200
208/3 33.05
1
120 5.3
1/4 141
617734 H3G7210 240/3 25.75 277 1.7
617581 P3G7210 480/3 13.72 277 1.7
606516 F3E7210-2 208/3 33.05
2
120 5.3
534390 H3G7210-2 240/3 25.75 277 1.7
617659 P3G7210-2 480/3 13.72 277 1.7
608602 F3E7215
15 500-1200
208/3 46.93
1
120 5.3
608848 H3G7215 240/3 37.78 277 1.7
606257 P3G7215 480/3 19.74 277 1.7
606943 F3E7215-2 208/3 46.93
2
120 5.3
534406 H3G7215-2 240/3 37.78 277 1.7
606066 P3G7215-2 480/3 19.74 277 1.7
608831 F3E7220-2
20 750-1600
208/3 63.81
2
120 8.3
1/2 163534413 H3G7220-2 240/3 50.61 277 2.5
606394 P3G7220-2 480/3 26.55 277 2.5
534420 F3E7223-2 23 1300-2000
208/3 74.84
2
120 11
3/4 201617888 H3G7223-2 240/3 59.63 277 4.3
606875 P3G7225-2 25 480/3 34.37 277 4.3
534437 H3G7230-2 30 1800-2800
240/3 78.47
2
277 6.3 2 MOTORS @
1/2 H.P. EACH 278606745 P3G7230-2 480/3 42.38 277 6.3
618007 P3G7235-2 35 480/3 48.39 277 6.3
606851 P3G7240-2 40
2000-3600
480/3 56.71
2
277 8.6 2 MOTORS @
3/4 H.P. EACH 319534444 P3G7245-2 45 480/3 62.72 277 8.6
606417 P3G7250-2 50 480/3 68.74 277 8.6
94
3 KW
5 KW
10&15 KW
20 KW
23&25 KW
A B L DISCHARGE
W H
DIMENSIONS
18"
18"
18" 18"
18" 18"
18"
14"14"12" 28"
14"
8"
8"
36"
36"
36"
36"
10"
10"
10"
22"
22"
26"26"
7200
SERIES
Air Flow
ACCESS DOORS
ELECTRIC
CONTROL
PANEL
Air
Inlet
L
W
2"
5 1/2"
STANDARD
FILTER=A X B
H
ON BOTH SIDES
OF UNIT
A
B
Filter Rack
3"
1" Filter Slot
Discharge
Screen
Disconnect
Switch
Inlet
Screen
Note:
Control Panel Access
Standard as Shown
For Panel on Opposite
Side Access Specify
And Order Figure 5.
DIMENSIONS
36
5218
25-30-35 KW
7200 L
W X H
DISCH'GE
SERIES
18 44 36
44 X 10
52 X 10
A B
40-45-50 KW
Sides Of Unit
On Both
Access
W
L
Control
Panel
5-1/2"
STANDARD
H
A
B
2"
Filter Rack
3"
1" Filter Slot
Discharge
Screen
Electric
Disconnect
Switch
NOTE:
Control Panel Access
Standard as Shown
For Panel on Opposite
Side Access Specify
And Order Figure 5.
DIMENSIONS
7200 Series A B L DISCHARGE
W H
3 KW 12” 14” 28” 14” 8”
5 KW 14” 18” 36” 18” 8”
10 & 15 KW 18” 18” 36” 18” 10”
20 KW 18” 22” 36” 22” 10”
23 & 25 KW 18” 26” 36” 26” 10”
Note: Control panel access standard as shown.
For panel on opposite side access specify and order
(Figure 5).
5 1/2”
STANDARD
Disconnect
Switch
ELECTRIC
CONTROL
PANEL
ACCESS DOORS
ON BOTH SIDES
OF UNIT
1” FILTER SLOT
Air
Inlet Inlet Screen
FILTER = A x B
A
Discharge
Screen
H
AIR FLOW
Filter Rack
W
L
2”
3”
B
DIMENSIONS
7200 Series A B L DISCHARGE
W H
25-30-35 KW 18” 44” 36” 44” 10”
40-45-50 KW 18” 52” 36” 52” 10”
5 1/2’
STANDARD
Note: Control panel access
standard as shown. For panel
on opposite side access specify
and order (Figure 5).
Disconnect
Switch
ELECTRIC
CONTROL
PANEL
ACCESS DOORS
ON BOTH SIDES
OF UNIT
1” FILTER SLOT
Filter Rack
W
L
H
Discharge
Screen
2”
3”
A
7200 Series Plenum Heater
Product Dimensions
*
* Control box depth depends on
actual components. Consult
factory for exact dimensions.
*
95
HOW TO DESIGNATE A MODEL:
Series Number
Element KW
3KW through 18KW
See model chart for KW options.
Element Voltage
F = 208V H = 240V G = 277V P = 480V
Phase
1 = Single Phase 3 = Three Phase
Control System
Blank = None T = Unit Thermostat
SSR = SSR Control
Motor Voltage
E = 120 G = 277 P = 480
Heater Stages
Blank = One 2 = Two
F 3 E 73 15 2 T
Product Specications
• 20 gauge galvanized cabinet.
• Variable speed motor, factory set at maximum. Motor speed
can be eld adjusted to increase heat rise.
• Acoustically insulated with 1” berglass.
• Access panels on bottom of unit.
• 24 Volt controls.
• Air ow switch.
• Terminal blocks.
• Single point connection.
• Dust tight control enclosure.
• Filter rack on inlet with throw away lter.
• Inlet and outlet screens and duct connection.
• Automatic primary limit control.
• Optional wall thermostat, unit thermostat or SSR control
which proportionally regulates heat output.
• Disconnect switch.
Standard Models
The 7300 Series LowBoy Plenum Heater is designed to t jobs where the clear space between the ceiling
and the oor above is as small as 11-3/4 inches.
Manufactured in U.S.A.
7300 Series Plenum Heater
SSR proportional control maximum: 45 Amps
Note: Products listed in this section are custom built and subject to 100% cancellation/restock charges.
UPC#
686334 MODEL KW CFM
RANGE
VOLTS/
PHASE
TOTAL AMPS for
MOTOR & HEATER STAGE MOTOR
VOLTAGE
FULL LOAD AMPS
for MOTOR ONLY MOTOR H.P. WT.
(LBS)
618076 F1G7305
5
170-950
208/1 26
1
277 2
1/4 163
617543 H1G7305 240/1 22
606301 G1G7305 277/1 20
617642 F3G7305 208/3 15
277 2534451 H3G7305 240/3 14
606455 P3G7305 480/3 8
609968 F3E7310
10
208/3 32
1
120 4
617734 H3G7310 240/3 26 277 2
617598 P3G7310 480/3 14 277 2
606363 F3E7310-2 208/3 32
2
120 4
534468 H3G7310-2 240/3 26 277 2
617697 P3G7310-2 480/3 14 277 2
534482 H3G7312
12
270-1500
240/3 32 1277 3
2 Motors @
1/4 HP Each 219
534499 P3G7312 480/3 17 277 3
608596 F3E7312-2 208/3 41
2
120 8
534505 H3G7312-2 240/3 32 277 3
617703 P3G7312-2 480/3 17 277 3
534529 H3G7315
15
240/3 39 1277 3
608725 P3G7315 480/3 21 277 3
618106 F3E7315-2 208/3 49
2
120 8
608510 H3G7315-2 240/3 39 277 3
617536 P3G7315-2 480/3 21 277 3
608763 P3G7318 18 480/3 25 1 277 3
606189 P3G7318-2 480/3 25 2 277 3
96
16 1/2"
Inlet
8 1/2"
5 & 10 KW
LDISCHARGE
A B
DIMENSIONS
10"8"45"
7300
SERIES C F G
6"
NOTE:Dimension C and G Will Vary
With Accessories.
28.75" 1"
H
11.75"
W
26"
Filter Rack
1" Filter
Air Flow
6"
C
G
F
5 1/2"
B
A
2"
H
W
L
Air
Flow
ELECTRIC
CONTROL
Panel
Discharge
Screen
Inlet
Screen
Disconnect
Switch
NOTE:
Control Panel access
Standard as shown
For Panel on Opposite
Side Access Specify
And Order Figure 5.
33 "
8 1/2" Inlet
12,15 & 18 KW
LDISCHARGE
A B
DIMENSIONS
20"8"
45"
7300
SERIES C F G
6"
NOTE:Dimension C and G Will Vary
With Accessories.
28.75" 2"
H
11.75"
W
43"
Air Flow
Filter Rack
(2) 1" Filters
6"
C
G
2"
H
AIR
FLOW
ELECTRIC
CONTROL
PANEL
W
B
A
F
L
Discharge
Screen
INlet
Screen
Disconnect
Switch
NOTE:
Control Panel Access
Standard as Shown
For Panel On Opposite
Side Access Specify
And Order Figure 5.
DIMENSIONS
7300 Series C F G H L W DISCHARGE
A B
5 & 10 KW 28, 75” 1” 6” 11.75” 45” 26” 8” 10”
DIMENSIONS
7300 Series C F G H L W DISCHARGE
A B
12, 15, & 18 KW 28, 75” 2” 6” 11.75” 45” 43” 8” 20”
Note: Control panel access
standard as shown. For panel
on opposite side access specify
and order (Figure 5).
Note: Dimension C and G will vary
with accessories.
Note: Control panel access
standard as shown. For panel
on opposite side access specify
and order (Figure 5).
Note: Dimension C and G will vary with accessories.
Disconnect
Switch
ELECTRIC
CONTROL
PANEL
Filter Rack
Air Flow
1” Filter
16 1/2”
8 1/2” Inlet
5 1/2”
Air Flow
L
C
W
HF
2” G
A
B
Discharge
Screen
Inlet
Screen
6”
L
G
W
B
H
C
Filter Rack
Air Flow
(2) 1” Filters
6”
8 1/2”
ELECTRIC
CONTROL
PANEL
Air Flow
Discharge
Screen
Disconnect
Switch
2”
A
F
33”
Inlet
Inlet
Screen
7300 Series Plenum Heater
Product Dimensions
97
PD Series Packaged Duct Heater
Standard Features
• Galvanized Steel Element Rack - Always 1”
shorter than duct height and 1/2” shorter than
duct width to allow insertion clearance
• Galvanized Steel Compartment with 1/2”
berglass Insulation & Hinged Cover
• Door Interlock Disconnect Switch
• Primary Automatic Reset Temp Limiting
Control
• Load Carrying Secondary over Temperature
Protective Device(s)
• Denite Purpose Magnetic Contactor(s)
• Differential Pressure Fan Inter-lock Switch
• Step Down Control Transformer / 24 Volt
• Permanently Attached Wiring Diagram on
inside of Terminal Compartment Cover
Manufactured in U.S.A.
Standard Models
UPC
686334 MODEL NUMBER KW
POWER
VOLTS/
PHASE
DUCT
WIDTH
W
DUCT
HEIGHT
A
DIMENSIONS
AMPS CONTROL
STEPS
WT.
(LBS.)
C E M
617000 PD5-128-1 5
240-1
12 8 4.75 6.5 26 20.9 1 22
617017 PD10-1810-1 10 18 10 4.75 6.5 28 41.7 2 37
617024 PD15-1812-1 15 18 12 4.75 6.5 27 62.5 2 33
617031 PD20-2012-1 20 20 12 9.125 7.5 31 83.3 2 37
617048 PD25-2016-1 25 20 16 9.125 7.5 38 104.2 3 56
617055 7PD2-128-1 2
277-1 12 8 4.75 6.5 26
7.2
1 21617062 7PD3.5-128-1 3.5 12.6
617079 7PD5-128-1 5 18.1
617086 8PD5-128-3 5
208-3
12 8 4.75 6.5 26 13.9 1 22
617093 8PD10-1810-3 10 18 10 4.75 6.5 22 27.8 1 27
617109 8PD15-1812-3 15 18 12 9.125 6.5 25 41.7 1 32
617116 8PD15-1812-2-3 15 18 12 9.125 6.5 28 41.7 2 34
617123 8PD20-2012-3 20 20 12 9.125 6.5 40 55.6 2 39
617130 8PD25-2016-3 25 20 16 9.125 6.5 29 69.5 2 58
617147 8PD30-2416-2-3 30 24 16 9.125 7.5 29 83.4 2 65
617154 8PD30-2416-3 30 24 16 9.125 7.5 35 83.4 3 60
617437 8PD35-2416-3 35 24 16 9.125 7.5 35 97.3 3 65
617321 8PD40-2416-3 40 24 16 9.125 7.5 43 111.2 3 75
617338 8PD45-3016-3 45 30 16 9.125 7.5 43 125.1 3 80
617345 8PD50-3016-3 50 30 16 9.125 7.5 43 139 3 85
617161 PD-128-3 5
240-3
12 8 4.75 6.5 26 12.1 1 21
617178 PD10-1812-3 10 18 10 4.75 6.5 22 24.1 1 26
617185 PD15-1812-1-3 15 18 12 4.75 6.5 20 36.2 1 30
617192 PD15-1812-2-3 15 18 12 9.125 6.5 26 36.2 2 33
617208 PD20-2012-3 19.9 20 12 9.125 6.5 28 47.9 2 39
617215 PD25-2016-3 25 20 16 9.125 6.5 29 60.2 2 57
617222 PD30-2416-2-3 30 24 16 4.75 6.5 25 72.3 2 57
617239 PD30-2416-3-3 30 24 16 9.125 6.5 35 72.3 3 65
617352 PD35-2416-3 35 24 16 9.125 7.5 35 84.3 3 65
617369 PD40-2416-3 40 24 16 9.125 7.5 35 96.3 3 75
617376 PD45-3016-3 45 30 16 9.125 7.5 43 108.4 3 80
617383 PD50-3016-3 49.8 30 16 9.125 7.5 43 120 3 85
617246 4PD5-128-3 5
480-3
12 8 4.75 6.5 26 6.1 1 21
617253 4PD10-1810-3 10 18 10 4.75 6.5 22 12.1 1 26
617260 4PD15-1812-3 15 18 12 4.75 6.5 20 18.1 1 30
617277 4PD15-1812-2-3 15 18 12 9.125 6.5 26 18.1 2 34
617284 4PD20-2012-3 20 20 12 9.125 6.5 26 24.1 2 39
617291 4PD25-2016-3 25 20 16 9.125 6.5 22 30.1 2 58
617307 4PD30-2416-2-3 30 24 16 4.75 6.5 18 36.2 2 65
617314 4PD30-2416-3-3 30 24 16 9.125 6.5 24 36.2 3 65
617390 4PD35-2416-3 35 24 16 9.125 6.5 26 42.2 3 65
617406 4PD40-2416-3 39.9 24 16 9.125 6.5 40 48.1 3 75
617420 4PD50-3016-3 50 30 16 9.125 6.5 36 60.2 3 85
98
HOW TO DESIGNATE A MODEL:
Duct Heater Series
Control Box Options
3 = Control Box on Heater, R = Remote
Duct Width Dimension
(over 55” heater must be flanged)
Duct Height Dimension
Kilowatts
Power Supply Volts
Phase
1 = Single Phase, 3 = Three Phase
Air Flow Direction
Internal Duct Insulation
0 = None, 1 = 1” Thick, 2 = 2” Thick
Control Volts
24, 120, 240, & 277
Number of Control Stages
Construction Options
F = Flange Mount, I = Insert
CHMS 3 I 18W 12H 15KW 480 3 24 2 HL 1
CHMS Series Finned Tubular Element Duct Heater
Finned tubular duct heaters provide many benets to the customer. They provide slower heating and cooling for closer temperature
regulation, electrical shock hazards are reduced, not as susceptible to shorting on the elements, are easily serviced, and better
withstand physical abuse.
Product Specications
General
1. Provide Series “CHMS” enclosed element electric duct heaters as manufactured and listed on schedule.
2. Power, voltage phase, control voltage, wattage, duct size, number of steps to be per schedule.
3. Heaters to be either slip-in or anged type as called for on schedule.
4. All heaters to be ETL listed for zero clearance to combustible surfaces and bear ETL label.
5. All heaters shall meet the requirements of the National Electric Code.
6. Standard terminal box, recessed terminal box, standard control cabinet, remote control cabinet and
element housing to be made of 18 gauge aluminized steel.
Element Construction
1. All elements to be made of high quality alloy resistor wire, centered and permanently encased within highly
compacted, rock-hard refractory material, surrounded by stainless steel sheath. All element terminations
shall be threaded stainless steel type to insure a positive connection to leads.
Terminal Box or Control Cabinet
1. Shall be constructed of 18 gauge Aluminized steel. All boxes to have a solid cover of the same gauge,
complete with a piano type hinge on the longest dimension, tool operated latch and pull ring.
Safety Controls
1. Primary over temperature protection shall be provided by built-in capillary type automatic reset thermal
cutout. Capillary cutout shall be U.L. listed and of the fail safe type.
2. Secondary over temperature protection shall consist of a sufcient number of capillary type manual resets
controlling back-up contactors. Capillary shall be the “fail safe” and “trip free” type.
3. All capillaries shall be installed in a protective Aluminum sheath. Sheath shall be etched and painted at
black to sense any over temperature condition the full length of heater face.
4. Over-current protection incorporating fuses must be provided for all heaters rated more than 48 Amperes,
and factory installed, within the heater enclosure or provided as a separate assembly by the heater
manufacturer. Heaters exceeding 48 Amperes total line current must be divided into sub-circuits of less
than 48 Amperes and be protected at not more than 60 Amperes.
Wiring Diagrams
1. A separate, complete and specic wiring diagram shall be permanently attached to each heater. Typical
wiring diagrams are not acceptable.
2. Control and line terminals in each heater shall be marked to correspond to the wiring diagram.
MINIMUM HEATER SIZE 8” X 8”
MAX KW 18.1 KW PER SQ. FT.
• Insert or Flanged construction • Integral or remote control panels • Available with Nema 4-4x-12 control panels
NOTE: All blanks must be lled in when
submitting an order to the factory.
• ABS type approved
Manufactured in U.S.A.
Air Flow Designations Guide for CHMS Series Duct Heaters
HR: Left to Right (shown)
HL: Right to Left
VU: Vertical Up
Control panel standard is extended upstream and same height as duct. This can be altered to accommodate available space.
99
How to designate an HF Series open coil duct heater:
Volts
Phase
Kilowatts
Width
Height
Control Volts
Stage
Options
Air Flow
Options
Model
480 3 HF 10KW 12W 12H 24 2 HR B G
HF Series Open Coil Element Duct Heater
Optional Controls & Features
Open coil duct heaters offer several advantages when used
properly. They release heat directly into the air stream
resulting in lower element temperatures, provide higher
wattage per square foot of duct area, have low pressure drop
due to high percentage of open area, are light weight, easily
installed, and economical with quick delivery available.
A: Additional Stage B: “A” Alloy Element Wire
C: Disconnecting Contactors D: PE Switch
E: Minimum fusing under 48 Amps F: Flanged Construction
G: Door Interlock Disconnect Switch H1: SCR Control Single Phase Only
H3: SCR Control Three Phase Only I: NEMA 1 Dust Tight Control Box
J: Electronic Step Controller
Standard Features
• Galvanized steel control box with optional 1/2”
insulation and hinged cover.
• Primary and secondary over temperature protection.
• De-energizing denite purpose contactors.
• Differential pressure fan interlock.
• 24 Volt control transformer.
• Fusing over 48 Amps (per NEC).
• Line terminal blocks.
• Insert or Flange. • Integral or remote controls. • Standard NEMA 1 control.
• Panel - available with NEMA 4-4x -12 panels as option integral or remote mounted.
• Comply with NEC specication.
Custom Specied Models
Air Flow Designations Guide for HF Series Duct Heaters
HR: Left to Right (shown)
HL: Right to Left
VU: Vertical Up
D: Vertical Down
Control panel standard is extended upstream and same height as duct. This can be altered to accommodate available space.
Manufactured in U.S.A.
100
HF Series Open Coil Element Duct Heater
General
1. Provide open coil, electric duct heaters, as manufactured and as listed in the schedule.
2. Power voltage and phase, control voltage, wattage, duct size, number of steps to be as per schedule.
3. Heaters to be either Slip-in or Flanged type as called for.
4. Three phase heaters shall have balanced three phase steps unless specied otherwise.
5. All heaters to be ETL listed for zero clearance to combustible surfaces and bear the ETL label.
6. All heaters shall meet the requirements of the latest National Electric Code.
7. Standard terminal box, recessed terminal box, standard control cabinet, remote control cabinet as well as element
housing and racks all to be made of heavy gauge galvanized steel. (Aluminized steel optional).
8. All heating coils to be made of high grade Nickel/Chromium resistance wire and terminated by means of a loop
of wire being sandwiched between stainless steel or Nickel plated washers and terminal hardware. All terminal
hardware to be insulated from the heater by a two piece ceramic bushing.
Element Assembly
1. To be of “Module” design with each module independently and easily removable
from the terminal box or control cabinet.
2. Each module to contain no more than 2 layers of element coils so that any one
coil may be replaced without disturbing others.
3. Element coils of each module to be on staggered spacing so that all coils per
module will be in the air stream, and shadowing (overheating) and/or blank
areas eliminated.
Element Housing
1. To be of No. 18 gauge galvanized (aluminized) steel and to be of roll-formed
construction with multiple brakes and ribs for stiffness and rigidity.
Element Rack
1. To be constructed of No. 20 gauge galvanized (aluminized) steel and formed with
multiple brakes and ribs for stiffness and rigidity.
2. Ceramic coil supports to be oating, but contained and easily replaceable.
3. Ceramic coil insulators to be on staggered spacing per rack to eliminate blank
areas in the air pattern thru the heaters, and provide uniform heating over the
entire cross section of the element.
4. Racks to support element coils on no more than 3 1/2” centers.
Terminal Box or Control Cabinet
1. Shall be constructed of heavy gauge galvanized steel (aluminized optional)
and in sizes up to 18” X 18” shall be No. 20 gauge and over to be No. 18 gauge.
All boxes to have a solid cover, of the same gauge, complete with a piano type
hinge on the longest side, approved tool operated latch and pull ring. Covers
over 48” long to be provided with two latches and pull rings.
2. Insulation consisting of 1/2” high density berglass will be provided, attached
to the cabinet, between the cabinet and the heating section.
3. Recessed terminal boxes used when ducts are internally insulated, or in air handling
units, to be of the same general construction as item 1 above.
Airow Direction
Heaters will be interchangeable for mounting in a horizontal or vertical duct except when
position sensitive Mercury contactors, SCR’s or capillary type limit controls are built-in. In
these cases, airow direction is as specied.
Safety Controls
1. Primary over temperature protection shall be provided by built in disc type
automatic reset thermal cutouts for duct heaters up to 10’ in width. Heaters over
40” high require two cutouts. Capillary type automatic reset thermal cutouts are
required for any heater 10’ wide or over. Capillary type controls to be UL listed
and of the “fail safe” type.
2. Secondary over temperature protection shall consist of a sufcient number of
load carrying replaceable disc controls to de-energize the elements if the
primary system fails.
3. Fuse link type heat limiters shall not be acceptable. All manual safety devices
shall be resetable thru the terminal box without removing the heater from the
duct.
Wiring Diagrams
1. A separate, complete and specic wiring diagram shall be permanently attached to each heater. Typical wiring
diagrams are not acceptable.
2. Control and line terminals in each heater shall be marked identical to the wiring diagram.
Heater Controls
1. All heater controls shall be factory mounted and wired.
2. Contactors shall be denite purpose type. No application type relays will be acceptable.
3. All controls shall be furnished as specied.
Product Specications
MINIMUM DUCT
SIZE 8” X 6”
MAX KW 20 KW
PER SQ. FT.
Note: Duct Heaters are available
up to 1000KW. KW and stages
shown above are limited example
of available models.
LINE
VOLTS KILOWATTS STAGE
120
208
240
0.5-2.5
1
2.6-5.0
5.1-8.0
8.1-11.0
11.1-15.0
15.1-19.0
2
19.1-24.0
24.1-28.0
28.1-30.0
30.1-34.0
3
34.1-38.0
38.1-42.0
42.1-46.0
46.1-51.6
51.7-55.0 4
55.1-60.0
277
0.5-2.5
12.6-5.0
5.1-8.0
8.1-11.0 2
11.1-15.0
480
600
0.5-2.5
1
2.6-5.0
5.1-8.0
8.1-11.1
11.2-15.0
215.1-19.0
19.1-24.0
24.1-28.0
3
28.1-30.0
30.1-34.0
34.0-39.9
40.0-44.0
44.1-48.0
48.1-53.0
53.1-56.0
56.1-60.0
101
Discharge Grille
Product Applications
Perimeter Heating; Lobby Heating; Plenum Heating; Kitchen Make-up Air
The fan pac offers the advantages of eliminating large and unsightly roof-top package equipment, and
through the roof duct systems which require costly installations with greater horsepower requirements.
Commercial or Industrial Unit Heaters
Since the fan pac incorporates a centrifugal blower designed to operate at static pressures of up to .70 inches
w.g., it is ideally suited for hanging in unused overhead spaces and forcing the warm air to occupied oor
areas. Ductwork can also be utilized to circulate the heated or ventilated air over large areas that may not
be in the vicinity of the fan pac.
Product Construction, Options & Features
Construction:
• All units ETL Listed as a total package with electric heat or hot water coils.
• Certied sound data by an independent testing laboratory.
• Single point pneumatic pipe connections.
• Each fan package is factory tested prior to shipment.
• Fan package, electric heat and optional disconnect switch are factory wired
as a package.
• 20 gauge galvanized cabinet acoustically insulated 1” berglass.
• 1” 4 lb. density core insulation is U.L. Listed and meets NFPA 90A
standards.
• Motors are single speed PSC with thermal over load protections, solid-state
speed controller, and are permanently lubricated.
• Access panels to the blower and motor are placed on both sides of the
cabinet.
• Fan and motor assembly is mounted on a special 16 Gauge pad and
completely isolated from the casing with rubber vibration mounts.
Options:
• Factory wired disconnect
switch.
• Throw away lter.
• Permanent lter.
• Electric heat or hot water
coils.
• Sealed access panels.
• 120 or 277 PSC motors.
• Dust tight electric panel.
• Acoustically lined
discharge plenum or return
air boot.
Features:
• The fan pac is a basic and very simple on/off operation for an application that requires a fan coil unit
with electric or hot water heat and a static pressure duct system of up to .70 inches w.g.
• The unit can be energized by electric controls (line voltage or low voltage) or by P.E. switches in
conjunction with a pneumatic system.
• SCR motor speed controller for continuous adjustable fan speed from minimum to maximum RPM.
• Built-in line voltage thermostats are available for unit heater type applications.
• Built-in control circuit transformers are available in 24V or 120V.
• Hot water coils are one row 1/2” O.D., two row 5/8” O.D. copper tubes. Aluminum ns are standard
with 10 FPI spacing.
• Transformers for fan motors are NOT available.
Manufactured in U.S.A.
RFH Series Fan Coil Units
RFH - W Model RFH - E Model
102 The fan packages shall be factory assembled complete with electric heat/hot water coils. Factory mounted
control panel shall provide all internal control and fan power wiring for a single point eld connection. An
optional factory mounted disconnect switch shall be furnished and prewired so as to disconnect all electrical
components in the fan package. A single point eld connection will be made at the disconnect switch. Fan
package must be labeled and listed by a nationally recognized and locally accepted testing laboratory, such
as ITS Intertek testing services. Fan packages must be tested for safety and in accordance with the latest
National Electric Code. Casing shall be a minimum of 20 gauge galvanized steel and acoustically insulated
with 1” berglass. The casing shall be Listed and meet NFPA and NBFU 90A requirements. Blower casing
shall be constructed of heavy gauge steel and baked enamel nish. Fan wheel shall be forward curved
centrifugal type, dynamically balanced and be driven by direct drive, single speed permanent split capacitor
motors. Motors shall be single phase, 1050 RPM. An electronic motor speed control shall be provided to
allow continuously adjustable fan speed from minimum to maximum and shall incorporate a minimum
voltage stop to insure motor cannot operate in stall mode. Fan assembly shall be mounted on a 16 gauge
steel sub-base, but shall be internally isolated with rubber-in-shear isolators to prevent vibration transfer to
the sub-base. Motors shall also be isolated with rubber-in-shear isolators between the motor mounting legs
and the blower casing. Fan motor assembly shall be accessible through access panels from both sides and
rear of cabinet (bottom and top access panels are not acceptable). Access panels shall have gasket to prevent
leakage and vibration transmission. An electric heater (hot water optional) shall be part of the total listed
package and shall be controlled by pneumatic, electric controls enclosed in a NEMA-1 enclosure on the side
of the cabinet. The panel shall be gasket sealed to prevent air leakage. Heater shall be the requested available
voltage and phase. Each fan package will be factory tested prior to shipment and certied as such. Each fan
shall have an optional throw-away or permanent lter, and an optional acoustically lined discharge plenum
or return air boot.
Custom Specied Models
Minimum CFM’S Based On KW
Product Specications
KW 5 7 9 10
CFM 400 500 600 700
KW 11 13 14 15 17
CFM 800 900 1000 1100 1200
KW 18 20 21 23 24
CFM 1300 1400 1500 1600 1700
KW 26 27 28.5 30
CFM 1800 1900 2000 2100
HOW TO DESIGNATE A MODEL:
Electric Heat
Hot Water Heat
RFH
RFH
E
W
500
500
5 KW
12.6 MBH
Disconnect Switch Washable Filter
Inlet Attenuator Totally
Enclosed Motor
SERIES
HEAT TYPE
SIZE
HEAT CAPACITY
OPTIONS
RFH Series Fan Coil Units
103
AIR FLOW AIR FLOW
AIR FLOW AIR FLOW
HOT WATER COIL LEFT
HAND CONNECTION.
ELECTRIC HEAT
STANDARD UNIT
STANDARD NO HEAT
UNIT
HAND CONNECTION
AIR FLOW
NOTE:DRAWING SHOWS ELECTRIC
HEAT ALSO AVAILABLE FOR NO
HEAT, AND HOT WATER COILS.
HOT WATER COIL RIGHT
FIG-1 FIG-2
FIG-3 FIG-4
FIG-5
Product Congurations
RFH Series Fan Coil Units
RFH RFH-W
RFH-E RFH-W
RFH
104
AIR FLOW
AIR
INLET
A
B
L
W
2"
5-1/2"
STANDARD
H
FAN PAC-Electric Heat
*See minimum CFM chart for all electric coil selections.
208V and 240V units use 277V rated motors - F.L.A. on 208V and 240V units same as 277V. For fan curve data consult factory
Model
Dimensions (Inches)
A B L Discharge
W H
300 12 14 28 14 8
500 14 18 36 18 8
750 18 18 36 18 10
1500 18 22 36 22 10
1800 18 26 36 26 10
2000 18 26 36 26 10
3000 18 44 36 44 10
4000 18 52 36 52 10
MFH PERFORMANCE DATA MFH-E ELECTRIC HEAT
MODEL MOTOR
H.P.
MOTOR
AMPS
FULL LOAD
AMPS
MOTOR
SPEED
CONTR.
EXTERNAL STATIC PRESSURE (in. H20)
.1 CFM .2 CFM .3 CFM .4 CFM .5 CFM .6 CFM .7 CFM
115V 277V
300 1 @ 1/15 2.90 1.00
MAX 270 245 225 180
Below 50 CFM
MIN 95 85 80 70
500 1 @ 1/6 3.60 1.10
MAX 740 700 640 590 530 490 450
MIN 290 275 250 230 210 200 190
750 1 @ 1/4 5.30 1.70
MAX 1390 1370 1350 1270 1230 1130 1040
MIN 450 440 430 420 410 405 400
1500 1 @1/2 8.30 2.50
MAX 1825 1790 1740 1660 1570 1450 1340
MIN 820 790 760 675 590 515 440
1800 1 @ 1/2 9.70 3.10
MAX 2120 2080 2040 1940 1850 1750 1670
MIN 850 840 820 810 790 740 630
2000 1 @ 3/4 11.00 4.30
MAX 2230 2160 2100 2040 1960 1860 1760
MIN 1200 1120 1040 950 860 750 640
3000 2 @ 1/2 19.40 6.30
MAX 3160 3040 2920 2790 2600 2440 2240
MIN 1840 1800 1760 1720 1640 1560 1460
4000 2 @ 3/4 22.00 8.60
MAX 4150 4050 3950 3830 3650 3250 3000
MIN 2200 2180 2160 2130 2080 2000 1900
RFH-E Series Fan Coil Units
105
AIR
INLET
A
B
L
W
2"
5 1/2"
STANDARD
H
DISCHARGE
GRILLE
FAN PAC-With Discharge Grille
AIR FLOW
*See minimum CFM chart for all electric coil selections.
208V and 240V units use 277V rated motors - F.L.A. on 208V and 240V units same as 277V. For fan curve data consult factory
MFH PERFORMANCE DATA MFH-DG ELECTRIC HEAT DISCHARGE GRILL
MODEL MOTOR
H.P.
MOTOR
AMPS
FULL LOAD
AMPS
MOTOR
SPEED
CONTR.
EXTERNAL STATIC PRESSURE (in. H20)
.1 CFM .2 CFM .3 CFM .4 CFM .5 CFM .6 CFM .7 CFM
115V 277V
300 1 @ 1/15 2.90 1.00 MAX 220 195 175 130 Below 50 CFM
MIN 95 85 80 70
500 1 @ 1/6 3.60 1.10 MAX 640 600 540 490 430 390 350
MIN 290 275 250 230 210 200 190
750 1 @ 1/4 5.30 1.70 MAX 1290 1270 1250 1170 1130 1030 940
MIN 450 440 430 420 410 405 400
1500 1 @1/2 8.30 2.50 MAX 1725 1690 1640 1560 1470 1350 1240
MIN 820 790 760 675 590 515 440
1800 1 @ 1/2 9.70 3.10 MAX 2020 1980 1940 1840 1750 1650 1570
MIN 850 840 820 810 790 740 630
2000 1 @ 3/4 11.00 4.30 MAX 2130 2060 2000 1940 1860 1760 1660
MIN 1200 1120 1040 950 860 750 640
3000 2 @ 1/2 19.40 6.30 MAX 3060 2940 2820 2960 2500 2340 2140
MIN 1840 1800 1760 1720 1640 1560 1460
4000 2 @ 3/4 22.00 8.60 MAX 4050 3950 3850 3730 3550 3150 2900
MIN 2200 2180 2160 2130 2080 2000 1900
Model Dimensions (Inches)
A B L H
500 14 18 36 10
750 18 18 36 12
1500 18 22 36 12
1800 18 26 36 12
2000 18 26 36 12
3000 18 44 36 12
4000 18 52 36 12
Basic Weight
(no options)
Model lbs.
300 95
500 115
750 138
1500 160
1800 175
2000 198
3000 275
4000 315
RFH-DG Series Fan Coil Units
106
AIR FLOW
DIMENSIONS
ABL
DISCHARGE
WH
500
750
1500
1800
2000
14" 18" 36" 18" 14"
18" 18" 36" 18" 18"
18" 22" 36" 22" 18"
18" 26" 36" 26" 18"
18" 26" 36" 26" 18"
B
A
L
H
W
5 1/2"
STANDARD
1"-4 SIDES
FILTER SIZE
= AxB
ACCESS DOOR ON
BOTH SIDES OF
UNIT
COIL CONNECTION
1-ROW 1/2" O.D. NOM.
2-ROW 5/8" O.D. NOM.
ELECTRIC CONTROL
PANEL
AIR
INLET
FAN PAC WITH
HOT WATER HEAT
DATE 6-29-01
MODEL
300 12" 14" 28" 14" 12"
Altitude Correction
Factors
Alt.
Ft.
Heat
Factor
0 1.00
2000 0.94
3000 0.90
4000 0.87
5000 0.84
6000 0.81
7000 0.78
HEATING CAPACITY CORRECTION FACTORS (AT VARIOUS WATER & AIR ENTERING TEMPERATURES)
Entering
Air °F
Entering Water Temperatures °F
100° 110° 120° 130° 140° 150° 160° 170° 180° 190° 200°
50° .455 .545 .635 .727 .818 .909 1.000 1.091 1.182 1.273 1.364
55° .409 .500 .591 .682 .773 .864 .955 1.045 1.136 1.227 1.318
60° .363 .455 .545 .636 .727 .818 .909 1.000 1.091 1.182 1.273
65° .318 .409 .500 .691 .682 .773 .864 .955 1.045 1.136 1.227
70° .272 .363 .455 .545 .636 .727 .818 .909 1.000 1.091 1.182
75° .227 .318 .409 .500 .691 .662 .773 .864 .955 1.045 1.136
80° .182 .272 .363 .455 .545 .636 .727 .818 .909 1.000 1.091
RFH-W Series Fan Coil Units
107
SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
100 150 200 250
300
1
S.P. DROP .01 .02 .04 .06
0.5 .09 4.0 4.8 5.5 5.9
1.0 .30 4.7 5.7 6.3 7.0
1.5 .50 5.0 6.0 6.7 7.4
2.0 1.0 5.1 6.2 7.0 7.7
3.0 2.0 5.2 6.3 7.2 8.0
4.0 3.0 5.3 6.4 7.3 8.2
5.0 5.0 5.3 6.5 7.4 8.3
2
S.P. DROP .02 .04 .08 .12
0.5 .02 6.4 7.8 8.7 9.3
1.0 .09 7.4 9.2 10.8 11.7
1.5 .15 7.8 9.8 11.2 12.5
2.0 .30 8.0 10.3 12.0 13.3
3.0 .60 8.1 10.7 12.4 13.9
4.0 1.0 8.2 10.9 12.8 14.5
5.0 1.5 8.3 11.1 13.1 14.8
SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
300 350 400 450
500
1
S.P. DROP 0.016 0.021 0.026 0.033
0.5 0.2 9.8 10.3 10.7 11.1
1.0 0.6 11.8 12.6 13.3 13.9
1.5 1.3 12.7 13.6 14.4 15.2
2.0 2.1 13.2 14.2 15.1 15.9
3.0 4.3 13.8 14.9 15.8 16.7
4.0 7.1 14.1 15.2 16.2 17.1
5.0 10.4 14.3 15.4 16.5 17.4
2
S.P. DROP 0.032 0.042 0.053 0.065
0.5 0.1 14.2 14.9 15.6 16.1
1.0 0.2 18.2 19.6 20.7 21.7
1.5 0.5 20.1 21.7 23.2 24.5
2.0 0.8 21.1 23.0 24.7 26.2
3.0 1.7 22.3 24.5 26.4 28.1
4.0 2.8 23.0 25.3 27.3 29.2
5.0 4.1 23.4 25.8 27.9 29.9
SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
500 600 700 800
750
1
S.P. DROP 0.025 0.034 0.045 0.057
0.5 0.2 12.7 13.3 13.8 14.2
1.0 0.8 16.2 17.3 18.2 19.0
1.5 1.7 17.9 19.2 20.3 21.3
2.0 2.8 18.8 20.3 21.6 22.7
3.0 5.6 19.8 21.5 23.0 24.3
4.0 9.3 20.4 22.2 23.8 25.2
5.0 13.7 20.8 22.6 24.3 25.7
2
S.P. DROP .049 .068 .090 .114
0.5 0.1 17.8 18.6 19.2 19.7
1.0 0.2 24.7 26.5 27.9 29.1
1.5 0.5 28.2 30.5 32.5 34.2
2.0 0.8 30.3 33.0 35.4 37.4
3.0 1.7 32.7 36.9 38.8 41.3
4.0 2.8 34.0 37.6 40.7 43.5
5.0 4.1 34.9 38.7 42.0 45.0
SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
1200 1300 1400 1500 1600
1500
1
S.P. DROP 0.079 0.091 0.104 0.118 0.132
0.5 0.3 16.6 16.9 17.1 17.2 17.4
1.0 1.0 23.5 24.0 24.5 24.9 25.3
1.5 1.9 27.1 27.8 28.4 29.0 29.6
2.0 3.2 29.3 30.1 30.8 31.5 32.3
3.0 6.5 31.8 32.8 33.7 34.5 35.3
4.0 10.8 33.2 34.3 35.3 36.2 37.1
5.0 16.0 34.2 35.3 36.4 37.4 38.3
2
S.P. DROP 0.159 0.183 0.209 0.263 0.265
1.0 0.3 34.8 35.4 36.0 36.5 37.0
1.5 0.6 42.4 43.4 44.4 45.2 46.0
2.0 1.0 47.4 48.8 50.0 51.1 52.2
4.0 3.2 57.4 59.4 61.3 63.0 64.7
6.0 6.5 61.6 63.9 66.2 68.2 70.2
8.0 10.8 64.0 66.5 68.9 71.2 73.3
10.0 16.0 65.5 68.1 70.7 73.1 75.3
RFH-W Series Fan Coil Units Hot Water Reheat Capacity
108 SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
1500 1600 1700 1800 1900
1800
1
S.P. DROP 0.086 0.096 0.107 0.118 0.130
1.0 1.1 26.7 27.2 27.6 27.9 28.3
1.5 2.2 31.4 32.0 32.6 33.1 33.6
2.0 3.7 34.3 35.0 35.7 36.4 37.0
2.5 5.4 36.3 37.1 37.9 38.6 39.3
3.0 7.5 37.7 38.6 39.5 40.3 41.0
4.0 12.4 40 40.7 41.6 42.5 43.4
5.0 18.3 41.0 42.0 43.1 44.0 44.9
2
S.P. DROP 0.171 0.192 0.214 0.237 0.261
1.0 0.3 38.4 38.9 39.3 39.7 40.1
1.5 0.7 48.0 48.8 49.6 50.3 51.0
2.0 1.1 54.5 55.7 56.7 57.7 58.6
4.0 3.7 67.8 69.7 71.4 73.0 74.6
6.0 7.5 73.3 75.8 77.9 79.9 81.8
8.0 12.4 76.9 79.3 81.6 83.8 85.9
10.0 18.3 79.0 81.6 84.0 86.3 88.5
SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
1800 1900 2000 2100
2000
1
S.P. DROP 0.118 0.130 0.143 0.156
1.0 1.1 27.9 28.3 28.6 28.9
1.5 2.2 33.1 33.6 34.1 34.5
2.0 3.7 36.4 37.0 37.6 38.1
2.5 5.4 38.6 39.9 40.0 40.6
3.0 7.5 40.3 41.0 41.8 42.4
4.0 12.4 42.5 43.4 44.2 45.0
5.0 18.3 44.0 44.9 45.8 46.7
2
S.P. DROP 0.237 0.261 0.286 0.312
1.0 0.3 39.7 40.1 40.4 40.8
1.5 0.7 50.3 51.0 51.6 52.2
2.0 1.1 57.7 58.6 59.5 60.3
4.0 3.7 73.0 74.6 76.0 77.4
6.0 7.5 79.9 81.8 83.5 85.3
8.0 12.4 83.8 85.9 87.8 89.7
10.0 18.3 86.3 88.5 90.6 92.7
SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
2000 2200 2400 2600 3000
3000
1
S.P. DROP 0.05 0.06 0.07 0.09 0.11
1.0 0.3 32.6 33.1 33.9 34.1 35.1
1.5 0.5 40.2 41.3 42.0 43.1 44.1
2.0 0.9 45.5 46.8 48.0 49.2 50.8
2.5 1.5 48.2 50.3 51.8 53.2 54.9
3.0 2.0 52.0 53.8 55.5 57.2 59.1
4.0 3.0 55.3 57.9 59.1 60.9 63.1
5.0 4.5 58.5 60.8 62.9 64.8 68.0
2
S.P. DROP 0.10 0.12 0.14 0.18 0.22
1.0 0.2 44.0 44.5 45.8 46.2 47.1
1.5 0.3 53.9 56.1 56.9 59.7 61.2
2.0 0.5 63.8 67.6 68.5 72.4 75.7
4.0 1.2 91.6 94.1 97.4 101.2 104.2
6.0 3.0 102.4 107.2 110.1 114.6 121.3
8.0 7.0 108.6 113.9 118.7 122.8 130.4
10.0 10.0 112.2 118.6 123.1 128.0 136.0
SIZE COIL
ROWS GPM H20 PD (TL)
REHEAT CAPACITY (MBH)@CFM
PRIMARY CFM @ HEATING
2500 2900 3100 3500 3900
4000
1
S.P. DROP 0.06 0.075 0.09 0.11 0.14
1.0 0.3 35.5 36.6 36.9 37.6 38.0
1.5 0.6 45.1 46.8 47.4 48.2 49.0
2.0 1.0 52.0 54.0 54.8 56.1 57.8
3.0 2.0 60.4 63.2 64.4 66.8 68.3
4.0 3.4 64.7 68.1 69.7 72.2 74.2
5.0 5.0 69.1 72.9 74.4 76.0 80.2
7.0 9.0 74.0 78.0 80.0 82.0 87.0
2
S.P. DROP 0.11 0.15 0.185 0.21 0.265
1.0 0.2 46.2 46.8 47.2 48.1 49.0
3.0 1.5 93.5 96.8 100.0 103.2 105.8
5.0 3.2 113.9 115.0 12.1 128.0 123.7
6.0 4.5 120.0 123.0 131.6 137.1 143.0
8.0 7.5 129.1 130.0 141.8 148.9 155.0
10.0 12.0 135.0 139.0 147.6 156.2 163.8
12.0 16.5 138.2 143.0 154.1 162.1 170.2
RFH-W Series Fan Coil Units Hot Water Reheat Capacity
1
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
Model Page Model Page Model Page Model Page
8510 28
8512 28
8513 28
8514 28
8515 28
8516 28
8517 28
8518 28
8519 28
8520 28
8522 28
8523 28
8524 28
8525 28
8526 28
8527 28
8528 28
8529 28
8530 28
8532 28
8533 28
8534 28
8535 28
8536 28
8537 28
8538 28
8539 28
9128 56
9136 56
9148 56
9160 56
9172 56
9184 56
9196 56
9328 58
9336 58
9348 58
9360 58
9372 58
9384 58
9396 58
91108 56
91120 56
93108 58
93120 58
31939009 69
31940009 69
31941009 69
63016209 69
63016249 69
63016279 69
63016489 69
A1560 80
DBTS IECR 62
170-TS 79
178 TMC 79
188 TASA 79
18D-2-30CF (Enclosed) 74
18D-2-30CF (Open) 74
18D-2-80CF (Enclosed) 74
198 TMC 79
21RCH2 35
21RCH3 35
21RCH4 35
21RCH5 35
21SCH2 36
21SCH3 36
21SCH4 36
21SCH5 36
21WD10T01 11
21WD15T01 11
21WD3T01 11
21WD5T01 11
21WD7T01 11
222-30-TH-208V 68
222-30-TH-240V 68
222-30-TH-277V 68
222-30-TH-480V 68
222-30-THSS-208V 68
222-30-THSS-240V 68
222-30-THSS-277V 68
222-30-THSS-480V 68
222-60-TH-208V 68
222-60-TH-240V 68
222-60-TH-277V 68
222-60-TH-480V 68
222-60-THSS-208V 68
222-60-THSS-240V 68
222-60-THSS-277V 68
222-60-THSS-480V 68
222-90-TH-208V 68
222-90-TH-240V 68
222-90-TH-277V 68
222-90-TH-480V 68
222-90-THSS-208V 68
222-90-THSS-240V 68
222-90-THSS-277V 68
222-90-THSS-480V 68
222-A30-TH-208V 68
222-A30-TH-240V 68
222-A30-TH-277V 68
222-A30-TH-480V 68
222-A30-THSS-208V 68
222-A30-THSS-240V 68
222-A30-THSS-277V 68
222-A30-THSS-480V 68
222-A60-TH-208V 68
222-A60-TH-240V 68
222-A60-TH-277V 68
222-A60-TH-480V 68
222-A60-THSS-208V 68
222-A60-THSS-240V 68
222-A60-THSS-277V 68
222-A60-THSS-480V 68
223-30-THSS-208V 69
223-30-THSS-240V 69
223-30-THSS-277V 69
223-30-THSS-480V 69
223-60-THSS-208V 69
223-60-THSS-240V 69
223-60-THSS-277V 69
223-60-THSS-480V 69
223-90-THSS-208V 69
223-90-THSS-240V 69
223-90-THSS-277V 69
223-90-THSS-480V 69
22WD10T01 11
22WD15T01 11
22WD3T01 11
22WD5T01 11
22WD7T01 11
23RCH2 35
23RCH3 35
23RCH4 35
23RCH5 35
23SCH2 36
23SCH3 36
23SCH4 36
23SCH5 36
23WD20T01 11
23WD25T01 11
23WD30T01 11
24A01G-3 87
24A05A-1 87
24A05E-1 87
24A06G-1 87
303EX16RW 34
303EX16RW 46
303EX32RW 34
303EX32RW 46
303EX8RW 34
303EX8RW 46
305EX16 39
305EX32 39
305EX8 39
30R 34
30R2 34
30R7 34
30R8 34
32T1 46
32T2 46
3310EX33R 45
3310EX33WR 45
3320EX16 40
3320EX33 40
3380EX33 34
3420EX16 43
3420EX34 43
3420EX8 43
342-30-TH-208V 68
342-30-TH-240V 68
342-30-TH-480V 68
342-30-THSS-208V 68
342-30-THSS-240V 68
342-30-THSS-480V 68
342-60-TH-208V 68
342-60-TH-240V 68
342-60-TH-480V 68
342-60-THSS-208V 68
342-60-THSS-240V 68
342-60-THSS-480V 68
342-90-TH-208V 68
342-90-TH-240V 68
342-90-TH-480V 68
342-90-THSS-208V 68
342-90-THSS-240V 68
342-90-THSS-480V 68
342-A30-TH-208V 68
342-A30-TH-240V 68
342-A30-TH-480V 68
342-A30-THSS-208V 68
342-A30-THSS-240V 68
342-A30-THSS-480V 68
342-A60-TH-208V 68
342-A60-TH-240V 68
342-A60-TH-480V 68
342-A60-THSS-208V 68
342-A60-THSS-240V 68
342-A60-THSS-480V 68
343-30-THSS-208V 69
343-30-THSS-240V 69
343-30-THSS-480V 69
343-60-THSS-208V 69
343-60-THSS-240V 69
2
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
343-60-THSS-480V 69
343-90-THSS-208V 69
343-90-THSS-240V 69
343-90-THSS-480V 69
3450EX16 43
3450EX34 43
3450EX8 43
3900AC 51
3900ACC 51
3900-CS 51
3900-CSC 51
3900DS 51
3900DSC 51
3900-ICS 51
3900-ICSC 51
3900-OCS 51
3900-OCSC 51
3900REC 51
3900RECC 51
3900T1 51
3900T1C 51
3900T2 51
3900T2C 51
3900WW120 51
3900WW28 51
3900WW36 51
3900WW48 51
3900WW60 51
3900WW72 51
3900WW96 51
39BS120 51
39BS120C 51
39BS28 51
39BS28C 51
39BS36 51
39BS36C 51
39BS48 51
39BS48C 51
39BS60 51
39BS60C 51
39BS72 51
39BS72C 51
39BS96 51
39BS96C 51
41RCH2A1 35
41RCH3A1 35
41RCH4A1 35
41RCH5A1 35
41SCH2 36
41SCH3 36
41SCH4 36
41SCH5 36
4300EX16 47
4300EX16W 47
4300EX16W 48
4300EX32 47
4300EX32W 47
4300EX32W 48
4300EX8 47
4300EX8W 47
4300EX8W 48
4300P 47
4300PB 40
4300PW 47
4300PW 48
43RCH2A1 35
43RCH4A1 35
43RCH5A1 35
43RCHA1 35
43SCH4 36
43SCH5 36
43SCHA1 36
43SCHA1 36
43T 47
43T 48
43T2 47
43WD10T01 11
43WD15T01 11
43WD20T01 11
43WD25T01 11
43WD30T01 11
43WD3T01 11
43WD40T01 11
43WD48T01 11
43WD5T01 11
43WD7T01 11
4400EX16 40
4400EX32 40
4400EX8 40
462-30-TH-480V 68
462-30-THSS-480V 68
462-60-TH-480V 68
462-60-THSS-480V 68
462-90-TH-480V 68
462-90-THSS-480V 68
462-A30-TH-480V 68
462-A30-THSS-480V 68
462-A60-TH-480V 68
462-A60-THSS-480V 68
463-30-THSS-480V 69
463-60-THSS-480V 69
463-90-THSS-480V 69
483 TM 79
48T2 48
4PD10-1018-3 97
4PD15-1218-2-3 97
4PD15-1218-3 97
4PD20-1220-3 97
4PD25-1620-3 97
4PD30-1624-2-3 97
4PD30-1624-3-3 97
4PD35-1624-3 97
4PD40-1624-3 97
4PD50-1630-3 97
4PD5-812-3 97
630-05129 73
630-10209 73
630-10249 73
630-16209 73
630-16249 73
630-16279 73
630-16489 73
630-25209 73
630-25249 73
630-25279 73
630-25489 73
631-16249 73
632-1620 69
632-1624 69
632-2548 69
6333D053834B30D0F1 25
6333D054134B30D0F1 25
6333D103834B30D0F1 25
6333D104134B30D0F1 25
641-35611 73
641-35621 73
641-35631 73
641-35641 73
641-35661 73
641-36051 73
641-36061 73
641-36071 73
641-37211 73
641-50011 73
641-50021 73
641-70001 73
641-70011 73
641-70021 73
641-70031 73
641-70041 73
641-70241 73
641-70251 73
641-70261 73
641-70271 73
641-70281 73
641-70321 73
671-3454 73
671-3492* 73
671-3784 73
671-3785 73
671-3786 73
671-5018 73
671-5056 73
671-5057 73
671-5058 73
671-5059 73
671-5060 73
671-5061 73
71RCH2 35
71RCH3 35
71RCH4 35
71RCH5 35
71SCH2 36
71SCH3 36
71SCH4 36
71SCH5 36
71WD10T01 11
71WD3T01 11
71WD5T01 11
71WD7T01 11
7PD2-812-1 97
7PD3.5-812-1 97
7PD5-812-1 97
81RCH2 35
81RCH3 35
81RCH4 35
81RCH5 35
81SCH2 36
81SCH3 36
81SCH4 36
81SCH5 36
81WD10T01 11
81WD15T01 11
81WD3T01 11
81WD5T01 11
81WD7T01 11
82WD10T01 11
82WD15T01 11
82WD3T01 11
82WD5T01 11
82WD7T01 11
83RCH2 35
83RCH3 35
83RCH4 35
3
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
83RCH5 35
83SCH2 36
83SCH3 36
83SCH4 36
83SCH5 36
83WD20T01 11
83WD25T01 11
83WD30T01 11
8PD10-1018-3 97
8PD15-1218-2-3 97
8PD15-1218-3 97
8PD20-1220-3 97
8PD25-1620-3 97
8PD30-1624-2-3 97
8PD30-1624-3 97
8PD35-1624-3 97
8PD40-1624-3 97
8PD45-1630-3 97
8PD50-1630-3 97
8PD5-812-3 97
9100EC 58
9100IC 56
9100OC 56
91BS012 56
91BS024 56
91BS036 56
91BS048 56
91BS060 56
91BS072 56
91BS084 56
91BS096 56
91BS108 56
91BS120 56
9300EC 58
9300IC 58
9300OC 58
93BS012 58
93BS024 58
93BS036 58
93BS048 58
93BS060 58
93BS072 58
93BS084 58
93BS096 58
93BS108 58
93BS120 58
A1600 22
A1601 22
A5105 15
A51100 18
A5120 15
A5150 15
A5175 18
A5520/UHB 10
A6176 17
A6176 86
AD5120 15
AD5150 15
AD5150 15
AD5175 15
AET5DWS 83
AET5SWS 83
AF3401-24 36
AF3402-24 36
AF3403-24 36
AFC2120T 41
AFC2130T 41
AFC2140T 41
AFC2150T 41
AFC2320 41
AFC2330 41
AFC2340T 41
AFC2350T 41
AFC7120T 41
AFC7130T 41
AFC7140T 41
AFC7150T 41
AFC8120T 41
AFC8130T 41
AFC8140T 41
AFC8150T 41
AFC8330 41
AFC8340T 41
AFC8350T 41
AFC8380 41
AFH2120T 41
AFH2130T 41
AFH2140T 41
AFH2150T 41
AFH2320 41
AFH2330 41
AFH2340T 41
AFH2350T 41
AFH7120T 41
AFH7130T 41
AFH7140T 41
AFH7150T 41
AFH8120T 41
AFH8130T 41
AFH8140T 41
AFH8150T 41
AFH8320 41
AFH8330 41
AFH8340T 41
AFH8350T 41
AG3401-24 36
AG3402-24 36
AG3403-24 36
AH3401-24 36
AH3402-24 36
AH3403-24 36
APS-3C 74
ASHDB ECL 63
ASHDB ECR 63
ASHDB IC 63
ASHDB OC 63
ASHDB SP 63
ASHDB WT 63
ASHDB-10 63
ASHDB-2 63
ASHDB-3 63
ASHDB-4 63
ASHDB-5 63
ASHDB-6 63
ASHDB-7 63
ASHDB-8 63
ASHDB-8/20-1000BS 63
ASHDB-8/20-100BS 63
ASHDB-8/20-200BS 63
ASHDB-8/20-300BS 63
ASHDB-8/20-400BS 63
ASHDB-8/20-500BS 63
ASHDB-8/20-600BS 63
ASHDB-8/20-700BS 63
ASHDB-8/20-800BS 63
ASHDB-8/20-900BS 63
ASHDB-9 63
ATR 60
B5105 15
B51100 18
B5150 15
B5175 18
BBS024A 55
BBS024AW 55
BBS024C 55
BBS028A 55
BBS028AW 55
BBS028C 55
BBS036A 55
BBS036AW 55
BBS036C 55
BBS040A 55
BBS040AW 55
BBS040C 55
BBS048A 55
BBS048AW 55
BBS048C 55
BBS060A 55
BBS060AW 55
BBS060C 55
BBS072A 55
BBS072AW 55
BBS072C 55
BBS084A 55
BBS084AW 55
BBS084C 55
BBS096A 55
BBS096AW 55
BBS096C 55
BBS120A 55
BBS120AW 55
BBS120C 55
BDR115 55
BDR115B 55
BDR115W 55
BOX 3310 40
BOX 3420 41
BOX 3450 41
BOX3310 34
BOX3310 45
C1025 19
C1-TD 8
C1-TDP 8
CB ECL 63
CB ECR 63
CB IC 63
CB MF 63
CB OC 63
CB SP 63
CB WT 63
CB-10 63
CB-1000BS 63
CB-100BS 63
CB-2 63
CB-200BS 63
CB-3 63
CB-300BS 63
CB-4 63
CB-400BS 63
CB-5 63
CB-500BS 63
CB-6 63
CB-600BS 63
CB-7 63
4
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
CB-700BS 63
CB-8 63
CB-800BS 63
CB-9 63
CB-900BS 63
CF36 82
CF48 82
CF60 82
CFHD36 82
CFHD48 82
CFHD60 82
CH-13 65
CH-13 65
CH-13 65
CH-13 65
CH-1320-3B 64
CH-1324-3B 64
CH-1327-3B 64
CH-1348-3B 64
CH-1357-3B 64
CH-2 65
CH-2 65
CH-212-1C 64
CH-220-1C 64
CH-2212-1C 77
CH-224-1C 64
CH-227-1C 64
CH-248-1C 64
CH-257-1C 64
CH-27 65
CH-27 65
CH-27 65
CH-27 65
CH-27 65
CH-2720-3C 64
CH-2724-3C 64
CH-2748-3C 64
CH-2757-3C 64
CH-4 65
CH-4 65
CH-4 65
CH-420-1C 64
CH-424-1C 64
CH-427-1C 64
CH-448-1C 64
CH-457-1C 64
CH-46C 71
CH-57C 71
CH-6 65
CH-6 65
CH-6 65
CH-6 65
CH-620-3C 64
CH-624-3C 64
CH-627-3C 64
CH-6424-1C 77
CH-648-3C 64
CH-657-3C 64
CHWG-222 69
CHWG-223 69
CHWG-342 69
CHWG-343 69
CHWG-462 69
CHWG-463 69
CIT-1 74
CKTD110 84
CP122 37
CP122i 37
CP123 37
CP123i 37
CP125 37
CP125i 37
CP127 37
CP127i 37
CP2202i 37
CP2203i 37
CP2205i 37
CP2207i 37
CP702 37
CP703 37
CP705 37
CP707 37
CP802 37
CP803 37
CP805 37
CP807 37
CS 55
CS 12 60
CS 6 60
CSB 55
CSW 55
CTBDB 55
CTBDB-TP 55
CTBDW 55
CTBSB 55
CTBSB-TP 55
CTBSW 55
CV10012X 38
CV10022Xi 38
CV10027X 38
CV100X 38
CV100Xi 38
CV100YX 38
CV11012X 38
CV11022Xi 38
CV11027X 38
CV110X 38
CV110Xi 38
CV110YX 38
CV12512X 38
CV12522Xi 38
CV12527X 38
CV125X 38
CV125Xi 38
CV125YX 38
CV4512X 38
CV4522Xi 38
CV4527X 38
CV45X 38
CV45Xi 38
CV45YX 38
CV6012X 38
CV6022Xi 38
CV6027X 38
CV60X 38
CV60Xi 38
CV60YX 38
CV7512X 38
CV7522Xi 38
CV7527X 38
CV75X 38
CV75Xi 38
CV75YX 38
CV9012X 38
CV9022Xi 38
CV9027X 38
CV90X 38
CV90Xi 38
CV90YX 38
CVB42X 38
CVB60X 38
CVB84X 38
CVCBX 38
CVSP 38
D1600 22
D1602 22
D1603 22
D1610 22
D1612 22
D1613 22
D2022H10BA 83
D2022H10BB 83
D2025H10DA 83
DBCT/DBCF-1000BS 61
DBCT/DBCF-100BS 61
DBCT/DBCF-200BS 61
DBCT/DBCF-300BS 61
DBCT/DBCF-400BS 61
DBCT/DBCF-500BS 61
DBCT/DBCF-600BS 61
DBCT/DBCF-700BS 61
DBCT/DBCF-800BS 61
DBCT/DBCF-900BS 61
DBCT-10/DBCF-10 61
DBCT-2/DBCF-2 61
DBCT-3/DBCF-3 61
DBCT-4/DBCF-4 61
DBCT-5/DBCF-5 61
DBCT-6/DBCF-6 61
DBCT-7/DBCF-7 61
DBCT-8/DBCF-8 61
DBCT-9/DBCF-9 61
DBF/DBT ECL 61
DBF/DBT ECR 61
DBF/DBT IC 61
DBF/DBT IECL 61
DBF/DBT IECR 61
DBF/DBT IF 61
DBF/DBT MF 61
DBF/DBT OC 61
DBF/DBT SP 61
DBF/DBT WT 61
DBF/DBT-1000BS 61
DBF/DBT-100BS 61
DBF/DBT-200BS 61
DBF/DBT-300BS 61
DBF/DBT-400BS 61
DBF/DBT-500BS 61
DBF/DBT-600BS 61
DBF/DBT-700BS 61
DBF/DBT-800BS 61
DBF/DBT-900BS 61
DBF-10/DBT-10 61
DBF-2/DBT-2 61
DBF-3/DBT-3 61
DBF-4/DBT-4 61
DBF-5/DBT-5 61
DBF-6/DBT-6 61
DBF-7/DBT-7 61
DBF-8/DBT-8 61
DBF-9/DBT-9 61
DBTS ECL 62
DBTS ECR 62
DBTS IC 62
5
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
DBTS IECL 62
DBTS MF 62
DBTS OC 62
DBTS SP 62
DBTS WT 62
DBTS-10 62
DBTS-1000BS 62
DBTS-100BS 62
DBTS-2 62
DBTS-200BS 62
DBTS-3 62
DBTS-300BS 62
DBTS-4 62
DBTS-400BS 62
DBTS-5 62
DBTS-500BS 62
DBTS-6 62
DBTS-600BS 62
DBTS-7 62
DBTS-700BS 62
DBTS-8 62
DBTS-800BS 62
DBTS-9 62
DBTS-900BS 62
DC-33 25
DC-46 25
DC-66 25
DC-79 25
DCS1003 13
DCS1003/5100 17
DCS202/5100 17
DCS303 13
DCS403 13
DCS403/5100 17
DCS603/5100 17
DCS803 13
DC-SK-1 64
DC-SK-1 76
DCS-MT303 23
DR115 55
DR115B 55
DR115W 55
DS 55
DS5105 15
DS51100 18
DS5120 15
DS5150 15
DS5175 18
DSB 55
DSW 55
E2903-024C 54
E2903-024HAW 52
E2903-024S 53
E2903-024SW 53
E2905-028C 54
E2905-028HAW 52
E2905-028S 53
E2905-028SW 53
E2906-036C 54
E2906-036HAW 52
E2906-036S 53
E2906-036SW 53
E2907-040C 54
E2907-040HAW 52
E2907-040S 53
E2907-040SW 53
E2910-048C 54
E2910-048HAW 52
E2910-048S 53
E2910-048SW 53
E2912-060C 54
E2912-060HAW 52
E2912-060S 53
E2912-060SW 53
E2915-072C 54
E2915-072HAW 52
E2915-072S 53
E2915-072SW 53
E3035DWBW 34
E3038DWBW 34
E3055T2DWB 39
E3055TDWB 39
E3058T2DWB 39
E3058TDWB 39
E3210RPW 46
E3210TRPW 46
E3215RPW 46
E3215TRPW 46
E3275RPW 46
E3275TRPW 46
E3312RP 44
E3312RPW 44
E3312T2RP 44
E3312T2RPW 44
E3312T2SRP 45
E3312T2SRPW 45
E3312TRP 44
E3312TRPW 44
E3312TSRP 45
E3312TSRPW 45
E3313RP 44
E3313RPW 44
E3313T2RP 44
E3313T2RPW 44
E3313T2SRP 45
E3313T2SRPW 45
E3313TRP 44
E3313TRPW 44
E3313TSRP 45
E3313TSRPW 45
E3321TD-RP 40
E3322TD-RP 40
E3323TD-RP 40
E3383D-RP 34
E3703-024 50
E3703-024B 50
E3705-028 50
E3705-028B 50
E3706-036 50
E3706-036B 50
E3707-040 50
E3707-040B 50
E3710-048 50
E3710-048B 50
E3712-060 50
E3712-060B 50
E3715-072 50
E3715-072B 50
E3904-28 49
E3904-28C 49
E3906-36 49
E3906-36C 49
E3910-48 49
E3910-48C 49
E3912-60 49
E3912-60C 49
E3915-72 49
E3915-72C 49
E4310RP 47
E4310RPW 47
E4310TRP 47
E4310TRPW 47
E4315RP 47
E4315RPW 47
E4315TRP 47
E4315TRPW 47
E4375RP 47
E4375RPW 47
E4375TRP 47
E4375TRPW 47
E4410TRP 40
E4415TRP 40
E4475TRP 40
E4810RPW 48
E4810TRPW 48
E4815RPW 48
E4815TRPW 48
E4875RPW 48
E4875TRPW 48
E8801050 30
E8802075 30
E8803100 30
E8804125 30
E8805150 30
E8806200 30
EPETD8D 6
EPETD8D 9
EPETD8D 83
EPETD8S 6
EPETD8S 9
EPETD8S 83
EPETP8D 6
EPETP8D 9
EPETP8D 83
EPETP8S 6
EPETP8S 9
EPETP8S 83
ET5D4S 83
ET5DS 83
ET5DTS 83
ET5DWS 83
ET5MS 83
ET5S4S 83
ET5SRS 83
ET5SS 83
ET5STS 83
ET5SWS 83
ETD5MS 83
ETD5SS 83
ETD5STS 83
F1F2605CA1 21
F1F2607CA1 21
F1F2610CA1 21
F1F5103N 16
F1F5103N 17
F1F5105N 16
F1F5105N 17
F1FUH03003 13
F1FUH05003 13
F1FUH07CA1 13
F1FUH10CA1 13
F1FUH12C03 13
F1FUH15CO3 13
F1FUH20CA1 13
6
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
F1FUH25CA1 13
F1G7203 93
F1G7205 93
F1G7305 95
F2903-024C 54
F2903-024HAW 52
F2903-024S 53
F2903-024SW 53
F2905-028C 54
F2905-028HAW 52
F2905-028S 53
F2905-028SW 53
F2906-036C 54
F2906-036HAW 52
F2906-036S 53
F2906-036SW 53
F2907-040C 54
F2907-040HAW 52
F2907-040S 53
F2907-040SW 53
F2910-048C 54
F2910-048HAW 52
F2910-048S 53
F2910-048SW 53
F2912-060C 54
F2912-060HAW 52
F2912-060S 53
F2912-060SW 53
F2915-072C 54
F2915-072HAW 52
F2915-072S 53
F2915-072SW 53
F2917-084C 54
F2917-084S 53
F2917-084SW 53
F2920-096C 54
F2920-096HAW 52
F2920-096S 53
F2920-096SW 53
F2925-120C 54
F2925-120HAW 52
F2925-120S 53
F2925-120SW 53
F2F5103N 16
F2F5103N 17
F2F5105N 16
F2F5105N 17
F2F5107CA1L 16
F2F5107CA1L 17
F2F5110CA1L 16
F2F5110CA1L 17
F2FUH05C03 13
F2FUH10C03 13
F30522T2DWB 39
F30522TDWB 39
F3052T2DWB 39
F3052TDWB 39
F3220RPW 46
F3220T2RPW 46
F3316RP 44
F3316RPW 44
F3316T2RP 44
F3316T2RPW 44
F3316T2SRP 45
F3316T2SRPW 45
F3316TRP 44
F3316TRPW 44
F3316TSRP 45
F3316TSRPW 45
F3317RP 44
F3317RPW 44
F3317T2RP 44
F3317T2RPW 44
F3317T2SRP 45
F3317T2SRPW 45
F3317TRP 44
F3317TRPW 44
F3317TSRP 45
F3317TSRPW 45
F3326TD-RP 40
F3327TD-RP 40
F3386D-RP 34
F3387D-RP 34
F3703-024 50
F3703-024B 50
F3705-028 50
F3705-028B 50
F3706-036 50
F3706-036B 50
F3707-040 50
F3707-040B 50
F3710-048 50
F3710-048B 50
F3712-060 50
F3712-060B 50
F3715-072 50
F3715-072B 50
F3717-084 50
F3717-084B 50
F3720-096 50
F3720-096B 50
F3725-120 50
F3725-120B 50
F3904-28 49
F3904-28C 49
F3906-36 49
F3906-36C 49
F3910-48 49
F3910-48C 49
F3912-60 49
F3912-60C 49
F3915-72 49
F3915-72C 49
F3920-96 49
F3920-96C 49
F3E7210 93
F3E7210-2 93
F3E7215 93
F3E7215-2 93
F3E7220-2 93
F3E7223-2 93
F3E7310 95
F3E7310-2 95
F3E7312 95
F3E7312-2 95
F3E7315 95
F3E7315-2 95
F3F2605CA1 21
F3F2607CA1 21
F3F2610CA1 21
F3F2615CA1 21
F3F2625CA1 21
F3F2630CA1 21
F3F2640CA1 21
F3F2650CA1 21
F3F5115CA1L 16
F3F5115CA1L 17
F3F5125CA1L 16
F3F5125CA1L 17
F3F5130CA1L 16
F3F5130CA1L 17
F3F5140CA1L 16
F3F5140CA1L 17
F3F5150CA1L 16
F3F5150CA1L 17
F3F5160CA1 19
F3F5170CA1 19
F3FUH03C03 13
F3FUH07C03 13
F3FUH12C03 13
F3FUH15C03 13
F3FUH20CA1 13
F3FUH25CA1 13
F3FUH30CA1 13
F3G7203 93
F3G7205 93
F3G7305 95
F4320RP 47
F4320RPW 47
F4320T2RP 47
F4320T2RPW 47
F4320TRP 47
F4320TRPW 47
F4420T2RP 40
F4420TRP 40
F4820RPW 48
F4820T2RPW 48
F4820TRPW 48
F8801050 30
F8802075 30
F8803100 30
F8804125 30
F8805150 30
F8806200 30
FAM33 25
FAM46 25
FAM66 25
FAM79 25
FEC-30-120 74
FEC-30-240 74
FEC-60-120 74
FEC-60-240 74
FEP-0812-1RA 8
FEP-0820-1RA 8
FEP-0820-3RA 9
FEP-0824-1RA 8
FEP-0824-3RA 9
FEP-0827-1RA 8
FEP-0848-1RA 8
FEP-0848-3RA 9
FEP-1612-1RA 8
FEP-1620-1RA 8
FEP-1620-3RA 9
FEP-1624-1RA 8
FEP-1624-3RA 9
FEP-1627-1RA 8
FEP-1648-1RA 8
FEP-1648-3RA 9
FEP-1657-1RA 8
FEP-1712-1RA 8
FEP-1720-1RA 8
FEP-1720-3RA 9
FEP-1724-1RA 8
FEP-1724-3RA 9
7
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
FEP-1727-1RA 8
FEP-1748-1RA 8
FEP-1748-3RA 9
FEP-1812-1RA 8
FEP-1820-1RA 8
FEP-1820-3RA 9
FEP-1824-1RA 8
FEP-1824-3RA 9
FEP-1827-1RA 8
FEP-1848-1RA 8
FEP-1848-3RA 9
FEP-3420-1RA 8
FEP-3420-3RA 9
FEP-3424-1RA 8
FEP-3424-3RA 9
FEP-3427-1RA 8
FEP-3448-1RA 8
FEP-3448-3RA 9
FEP-3457-1RA 8
FEP-3620-1RA 8
FEP-3620-3RA 9
FEP-3624-1RA 8
FEP-3624-3RA 9
FEP-3627-1RA 8
FEP-3648-1RA 8
FEP-3648-3RA 9
FEP-3657-1RA 8
FEP-3820-1RA 8
FEP-3820-3RA 9
FEP-3824-1RA 8
FEP-3824-3RA 9
FEP-38271-RA 8
FEP-3848-1RA 8
FEP3848-3RA 9
FEP-7620-1RA 8
FEP-7620-3RA 9
FEP-7624-1RA 8
FEP-7624-3RA 9
FEP-7627-1RA 8
FEP-7648-1RA 8
FEP-7648-3RA 9
FEP-7657-1RA 8
FES-0924-1C 78
FES-1024-1CA 78
FES-1520-3A 78
FES-1524-1A 78
FES-1524-3E 78
FES-1548-3E 78
FES-1560-3A 78
FES-3048-3A 78
FES-3060-3A 78
FES-4548-3 78
FES-4560-3 78
FFH-512A 72
FFH-912B 72
FH15 81
FH1T 81
FHK-1 77
FHK-1324-3A 76
FHK-1348-3A 76
FHK-212-1CA 76
FHK-224-1A 76
FHK-248-1A 76
FHK-424-1A 76
FHK-448-1A 76
FHK-624-1CA 76
FHK-624-3A 76
FHK-648-3A 76
FPC2110 75
FPC2120 75
FPC2140 75
FPC2160 75
FPC2210 75
FPC2220 75
FPC2240 75
FPC2260 75
FPC4110 75
FPC4120 75
FPC4140 75
FPC4160 75
FPC4210 75
FPC4220 75
FPC4240 75
FPC4260 75
FPC7110 75
FPC7120 75
FPC7140 75
FPC7160 75
FPC7210 75
FPC7220 75
FPC7240 75
FPC7260 75
FPC8110 75
FPC8120 75
FPC8140 75
FPC8160 75
FPC8210 75
FPC8220 75
FPC8240 75
FPC8260 75
FS5101 17
FS5101 19
FS5101 19
FS5101 19
FS5101 19
FS5101 19
FS5101 19
FS5101 19
FS5102 17
FS5102 19
FS5102 19
FS5102 19
FS5102 19
FS5102 19
FSW5111 17
FSW5112 17
FSW5112 19
FSW5112 22
G1G2605CA1 21
G1G2607CA1 21
G1G2610CA1 21
G1G5103N 16
G1G5103N 17
G1G5105N 16
G1G5105N 17
G1G5107CA1L 16
G1G5107CA1L 17
G1G5110CA1N 16
G1G5110CA1N 17
G1G7203 93
G1G7205 93
G1G7305 95
G1GUH03003 13
G1GUH05003 13
G1GUH07CA1 13
G1GUH10CA1 13
G2903-024C 54
G2903-024HAW 52
G2903-024S 53
G2903-024SW 53
G2905-028C 54
G2905-028HAW 52
G2905-028S 53
G2905-028SW 53
G2906-036C 54
G2906-036HAW 52
G2906-036S 53
G2906-036SW 53
G2907-040C 54
G2907-040HAW 52
G2907-040S 53
G2907-040SW 53
G2907-048C 54
G2907-048HAW 52
G2907-048S 53
G2907-048SW 53
G2909-060C 54
G2909-060HAW 52
G2909-060S 53
G2909-060SW 53
G2910-048C 54
G2910-048HAW 52
G2910-048S 53
G2910-048SW 53
G2911-072C 54
G2911-072HAW 52
G2911-072S 53
G2911-072SW 53
G2912-060C 54
G2912-060HAW 52
G2912-060S 53
G2912-060SW 53
G2913-084C 54
G2913-084S 53
G2913-084SW 53
G2915-072C 54
G2915-072HAW 52
G2915-072S 53
G2915-072SW 53
G2915-096C 54
G2915-096HAW 52
G2915-096S 53
G2915-096SW 53
G2917-084C 54
G2917-084S 53
G2917-084SW 53
G2918-120C 54
G2918-120HAW 52
G2918-120S 53
G2918-120SW 53
G2920-096C 54
G2920-096HAW 52
G2920-096S 53
G2920-096SW 53
G2925-120C 54
G2925-120HAW 52
G2925-120S 53
G2925-120SW 53
G3032DWBW 34
G3052T2DWB 39
G3052TDWB 39
G3314RP 44
G3314RPW 44
G3314T2RP 44
8
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
G3314T2RPW 44
G3314TRP 44
G3314TRPW 44
G3315RP 44
G3315RPW 44
G3315T2RP 44
G3315T2RPW 44
G3315TRP 44
G3315TRPW 44
G3316RP 44
G3316RPW 44
G3316T2RP 44
G3316T2RPW 44
G3316TRP 44
G3316TRPW 44
G3317RP 44
G3317RPW 44
G3317T2RP 44
G3317T2RPW 44
G3317TRP 44
G3317TRPW 44
G3323TD-RP 40
G3324TD-RP 40
G3325TD-RP 40
G3326TD-RP 40
G3327TD-RP 40
G3383D-RP 34
G3384D-RP 34
G3385D-RP 34
G3386D-RP 34
G3387D-RP 34
G3703-024 50
G3703-024B 50
G3705-028 50
G3705-028B 50
G3706-036 50
G3706-036B 50
G3707-040 50
G3707-040B 50
G3707-048 50
G3707-048B 50
G3709-060 50
G3709-060B 50
G3710-048 50
G3710-048B 50
G3711-072 50
G3711-072B 50
G3712-060 50
G3712-060B 50
G3713-084 50
G3713-084B 50
G3715-072 50
G3715-072B 50
G3715-096 50
G3715-096B 50
G3717-084 50
G3717-084B 50
G3718-120 50
G3718-120B 50
G3720-096 50
G3720-096B 50
G3725-120 50
G3725-120B 50
G3904-28 49
G3904-28C 49
G3906-36 49
G3906-36C 49
G3910-48 49
G3910-48C 49
G3912-60 49
G3912-60C 49
G3915-72 49
G3915-72C 49
G3920-96 49
G3920-96C 49
G8801050 30
G8802075 30
G8803100 30
G8804125 30
G8805150 30
G8806200 30
GCH-4000 80
GF-SK-1 64
GF-SK-1 76
H1D1AA 85
H1G7203 93
H1G7205 93
H1G7305 95
H1H2605CA1 21
H1H2607CA1 21
H1H2610CA1 21
H1HUH03003 13
H1HUH05003 13
H1HUH07CA1 13
H1HUH12C03 13
H1HUH15C03 13
H1HUH20CA1 13
H1HUH25CA1 13
H1HUH30CA1 13
H2903-024C 54
H2903-024CI 54
H2903-024HAW 52
H2903-024S 53
H2903-024SW 53
H2903-24AWi 52
H2905-028C 54
H2905-028CI 54
H2905-028HAW 52
H2905-028S 53
H2905-028SW 53
H2905-28AWi 52
H2906-036C 54
H2906-036C 54
H2906-036HAW 52
H2906-036S 53
H2906-036SW 53
H2906-36AWi 52
H2907-040C 54
H2907-040C 54
H2907-040HAW 52
H2907-040S 53
H2907-040SW 53
H2907-40AWi 52
H2910-048C 54
H2910-048CI 54
H2910-048HAW 52
H2910-048S 53
H2910-048SW 53
H2910-48AWi 52
H2912-060C 54
H2912-060C 54
H2912-060HAW 52
H2912-060S 53
H2912-060SW 53
H2912-60AWi 52
H2915-072C 54
H2915-072CI 54
H2915-072HAW 52
H2915-072S 53
H2915-072SW 53
H2915-72AWi 52
H2917-084C 54
H2917-084CI 54
H2917-084S 53
H2917-084SW 53
H2917-84AWi 52
H2920-096C 54
H2920-096CI 54
H2920-096HAW 52
H2920-096S 53
H2920-096SW 53
H2920-120AWi 52
H2925-120C 54
H2925-120CI 54
H2925-120HAW 52
H2925-120S 53
H2925-120SW 53
H2HUH05C03 13
H2HUH07C03 13
H3032DWBW 34
H30522T2DWB 39
H30522TDWB 39
H3052T2DWB 39
H3052TDWB 39
H3275RPW 46
H3275T2RPW 46
H3317RP 44
H3317RPW 44
H3317T2RP 44
H3317T2RPW 44
H3317T2SRP 45
H3317T2SRPW 45
H3317TRP 44
H3317TRPW 44
H3317TSRP 45
H3317TSRPW 45
H3327TD-RP 40
H3387D-RP 34
H3703-024 50
H3703-024B 50
H3705-028 50
H3705-028B 50
H3706-036 50
H3706-036B 50
H3707-040 50
H3707-040B 50
H3710-048 50
H3710-048B 50
H3712-060 50
H3712-060B 50
H3715-072 50
H3715-072B 50
H3717-084 50
H3717-084B 50
H3720-096 50
H3720-096B 50
H3725-120 50
H3725-120B 50
H3904-28 49
H3904-28C 49
H3906-36 49
H3906-36C 49
H3910-48 49
H3910-48C 49
9
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
H3912-60 49
H3912-60C 49
H3915-72 49
H3915-72C 49
H3920-96 49
H3920-96C 49
H3G7203 93
H3G7205 93
H3G7210 93
H3G7210-2 93
H3G7215 93
H3G7215-2 93
H3G7220-2 93
H3G7223-2 93
H3G7230-2 93
H3G7305 95
H3G7310 95
H3G7310-2 95
H3G7312 95
H3G7312-2 95
H3G7315 95
H3G7315-2 95
H3H2605CA1 21
H3H2607CA1 21
H3H2610CA1 21
H3H2615CA1 21
H3H2620CA1 21
H3H2625CA1 21
H3H2630CA1 21
H3H2640CA1 21
H3H2650CA1 21
H3H5605T 23
H3HUH03C03 13
H3HUH12C03 13
H3HUH15C03 13
H3HUH20CA1 13
H3HUH25CA1 13
H3HUH30CA1 13
H46D1214 85
H474 TMC 80
H5520/HMK 10
H5550/HMK 10
H8801050 30
H8801050i 30
H8802075 30
H8802075i 30
H8803100 30
H8803100i 30
H8804125 30
H8804125i 30
H8805150 30
H8805150i 30
H8806200 30
H8806200i 30
HDWG-13 64
HDWG-2 64
HDWG-27 64
HDWG-4 64
HDWG-6 64
HF1B5103N 16
HF1B5103N 17
HF1B5105N 16
HF1B5105N 17
HF2B5103N 16
HF2B5103N 17
HF2B5105N 16
HF2B5105N 17
HF2B5107CA1L 16
HF2B5107CA1L 17
HF2B5110CA1L 16
HF2B5110CA1L 17
HF2HUH10C03 13
HF3210RPW 46
HF3210T2RPW 46
HF3215RPW 46
HF3215T2RPW 46
HF3220RPW 46
HF3220T2RPW 46
HF3222RPW 46
HF3222T2RPW 46
HF3315RP 44
HF3315RPW 44
HF3315T2RP 44
HF3315T2RPW 44
HF3315T2SRP 45
HF3315T2SRPW 45
HF3315TRP 44
HF3315TRPW 44
HF3315TSRP 45
HF3315TSRPW 45
HF3316RP 44
HF3316RPW 44
HF3316T2RP 44
HF3316T2RPW 44
HF3316T2SRP 45
HF3316T2SRPW 45
HF3316TRP 44
HF3316TRPW 44
HF3316TSRP 45
HF3316TSRPW 45
HF3323TD-RP 40
HF3324TD-RP 40
HF3325TD-RP 40
HF3326TD-RP 40
HF3384D-RP 34
HF3385D-RP 34
HF3386D-RP 34
HF3B51100CA1 19
HF3B5115CA1L 16
HF3B5115CA1L 17
HF3B5120CA1L 16
HF3B5120CA1L 17
HF3B5125CA1L 16
HF3B5125CA1L 17
HF3B5130CA1L 16
HF3B5130CA1L 17
HF3B5140CA1L 16
HF3B5140CA1L 17
HF3B5150CA1L 16
HF3B5150CA1L 17
HF3B5160CA1 19
HF3B5170CA1 19
HF3B5180CA1 19
HF3B5190CA1 19
HF4310RP 47
HF4310RPW 47
HF4310T2RP 47
HF4310T2RPW 47
HF4310TRP 47
HF4310TRPW 47
HF4315RP 47
HF4315RPW 47
HF4315T2RP 47
HF4315T2RPW 47
HF4315TRP 47
HF4315TRPW 47
HF4320RP 47
HF4320RPW 47
HF4320T2RP 47
HF4320T2RPW 47
HF4320TRP 47
HF4320TRPW 47
HF4375RP 47
HF4375RPW 47
HF4375T2RP 47
HF4375T2RPW 47
HF4375TRP 47
HF4375TRPW 47
HF4410T2RP 40
HF4415T2RP 40
HF4420T2RP 40
HF4475T2RP 40
HF4810RPW 48
HF4810T2RPW 48
HF4815RPW 48
HF4815T2RPW 48
HF4820RPW 48
HF4820T2RPW 48
HF4875RPW 48
HF4875T2RPW 48
HF5605T 23
HF684TC 80
HF685TC 80
HF686TC 80
HIHUH10CA1 13
HLA 12-208160-3.0-24 5
HLA 12-208160-5.0-24 5
HLA 12-208160-7.5-24 5
HLA 12-208360-3.0-24 5
HLA 12-208360-5.0-24 5
HLA 12-208360-7.5-24 5
HLA 12-240160-3.0-24 5
HLA 12-240160-5.0-24 5
HLA 12-240160-7.5-24 5
HLA 12-240360-3.0-24 5
HLA 12-240360-5.0-24 5
HLA 12-240360-7.5-24 5
HLA 12-480360-3.0-24 5
HLA 12-480360-5.0-24 5
HLA 12-480360-7.5-24 5
HLA 16-208360-10.0-24 5
HLA 16-240160-10.0-24 5
HLA 16-240360-10.0-24 5
HLA 16-480360-10.0-24 5
HLA 20-208360-15.0-24 5
HLA 20-240360-15.0-24 5
HLA 20-480360-15.0-24 5
HLA 20-480360-20.0-24 5
HLA 20-480360-25.0-24 5
HLA 20-600360-15.0-24 5
HLA 20-600360-20.0-24 5
HLA 20-600360-25.0-24 5
HLHM 6
HLPM1015 6
HLPM1525 6
HLPM37 6
HLT-1 6
HLT-1 9
HLT-1 83
HLT-2 6
HLT-2 9
HLT-2 83
HLWM10 6
HLWM1525 6
10
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
HLWM37 6
HP-11-QT 77
HP-5-QT 77
HP6-1000120-2CT 91
HP6-1000120-2CT 91
HP6-1000120-2CTRP 92
HP6-1000120-2T 91
HP6-1000120-2T 91
HP6-1000120-2TRP 92
HP6C-12PK 91
HP6H-12PK 91
HP-6-QT 77
HP8-1440120-2CT 91
HP8-1440120-2CT 91
HP8-1440120-2CTRP 92
HP8-1440120-2T 91
HP8-1440120-2T 91
HP8-1440120-2TRP 92
HP8C-12PK 91
HP8H-12PK 91
ICH-240C 80
IDS 60
IDS 30 60
IDS 40 60
ITD 60
ITS 60
J3326TD-RP 40
J3327TD-RP 40
JK 55
JKB 55
JKW 55
K3326TD-RP 40
K3327TD-RP 40
KB33 25
KB46 25
KB66 25
KB79 25
KT110 84
KT121 84
KTD110 84
KTO110 84
KTO121 84
L06Y-01 84
L08Y-01 84
L8801050 30
L8802075 30
L8803100 30
L8804125 30
L8805150 30
L8806200 30
LVRS 55
LVRSB 55
LVRSW 55
LVTR 60
M2903-024CI 54
M2903-24AWi 52
M2905-028CI 54
M2905-28AWi 52
M2906-036CI 54
M2906-36AWi 52
M2907-040CI 54
M2907-40AWi 52
M2910-048CI 54
M2910-48AWi 52
M2912-060CI 54
M2912-60AWi 52
M2915-072CI 54
M2915-72AWi 52
M2917-084CI 54
M2917-84AWi 52
M2920-096CI 54
M2925-120AWi 52
M2925-120CI 54
M3210T2RPWi 46
M3215T2RPWi 46
M3220T2RPWi 46
M3222T2RPWi 46
M3315T2SRPWi 45
M3316T2SRPWi 45
M3324TD-RPi 40
M3325TD-RPi 40
M3384D-RPi 34
M3385D-RPi 34
M3386D-RPi 34
M3472T2i 36
M3473T2i 36
M3474T2i 36
M3482T2i 35
M3483T2i 35
M3484T2i 35
M4310T2RPi 47
M4315T2RPi 47
M4320T2RPi 47
M4375T2RPi 47
M8801050i 30
M8802075i 30
M8803100i 30
M8804125i 30
M8805150i 30
M8806200i 30
MFHE-0300-6-EAA 92
MFHE-0300-6-EAAC 92
MFHE-0300-6-EAACRP 92
MFHE-0300-6-EAARP 92
MFHE-0300-6-FAAF2D 92
MFHE-0300-6-HAA 92
MFHE-0300-6-HAAF2D 92
MFHE-0300-6-HAARP 92
MFHE-0300-8-EAA 92
MFHE-0300-8-EAAC 92
MFHE-0300-8-EAACRP 92
MFHE-0300-8-EAARP 92
MFHE-0300-8-HAA 92
MFHE-0300-8-HAARP 92
MM-13A 72
MM-18A 72
MM-24A 72
MM-33A 72
MM-46A 72
MS4122 33
MS4123 33
MS4124 33
MS4125 33
MS4126 33
MSE4120-12 33
N3472T2i 36
N3473T2i 36
N3474T2i 36
N3482T2i 35
N3483T2i 35
N3484T2i 35
OCH-46-120V 70
OCH-46-120V-SS 70
OCH-46-208V 70
OCH-46-208V-SS 70
OCH-46-240V 70
OCH-46-240V-SS 70
OCH-46-277V 70
OCH-46-277V-SS 70
OCH-57-208V 70
OCH-57-208V-SS 70
OCH-57-240V 70
OCH-57-240V-SS 70
OCH-57-277V 70
OCH-57-277V-SS 70
OCH-57-480V 70
OCH-57-480V-SS 70
OCH-EBK-120 70
OCH-EBK-208 70
OCH-EBK-240 70
OCH-EBK-480 70
OCHWG-46 70
OCHWG-46 71
OCHWG-57 70
OCHWG-57 71
OFG 51100 18
OFG 5175 18
OFG5101 15
OFG5102 15
OFG5103 15
P3G7203 93
P3G7205 93
P3G7210 93
P3G7210-2 93
P3G7215 93
P3G7215-2 93
P3G7220-2 93
P3G7225-2 93
P3G7230-2 93
P3G7235-2 93
P3G7240-2 93
P3G7245-2 93
P3G7250-2 93
P3G7305 95
P3G7310 95
P3G7310-2 95
P3G7312 95
P3G7312-2 95
P3G7315 95
P3G7315-2 95
P3G7318 95
P3G7318-2 95
P3P2605CA1 21
P3P2607CA1 21
P3P2610CA1 21
P3P2615CA1 21
P3P2620CA1 21
P3P2625CA1 21
P3P2630CA1 21
P3P2640CA1 21
P3P2650CA1 21
P3P5103CA1N 16
P3P5103CA1N 17
P3P5105CA1N 16
P3P5105CA1N 17
P3P5107CA1L 17
P3P5107CA1N 16
P3P51100CA1 19
P3P5110CA1N 16
P3P5110CA1N 17
P3P5115CA1L 17
P3P5115CA1N 16
P3P5120CA1N 16
P3P5120CA1N 17
11
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
P3P5125CA1N 16
P3P5125CA1N 17
P3P5130CA1N 16
P3P5130CA1N 17
P3P5140CA1N 16
P3P5140CA1N 17
P3P5150CA1N 16
P3P5150CA1N 17
P3P5160CA1 19
P3P5170CA1 19
P3P5180CA1 19
P3P5190CA1 19
P3P5605T 23
P3PUH03CA1 13
P3PUH05CA1 13
P3PUH07CA1 13
P3PUH10CA1 13
P3PUH12CA1 13
P3PUH15CA1 13
P3PUH20CA1 13
P3PUH25CA1 13
P3PUH30CA1 13
P3PUH40CA1 13
P3PUH48CA1 13
P5520/PMK 10
P5550/PMK 10
P8801050 30
P8802075 30
P8803100 30
P8804125 30
P8805150 30
P8806200 30
PCH-48C 77
PD10-1018-1 97
PD10-1018-3 97
PD15-1218-1 97
PD15-1218-1-3 97
PD15-1218-2-3 97
PD20-1220-1 97
PD20-1220-3 97
PD25-1620-1 97
PD25-1620-3 97
PD30-1624-2-3 97
PD30-1624-3-3 97
PD35-1624-3 97
PD40-1624-3 97
PD45-1630-3 97
PD50-1630-3 97
PD5-812-1 97
PD-812-3 97
PHLA12-208160-3.0-24-TDP
7
PHLA12-208160-5.0-24-TDP
7
PHLA12-208160-7.5-24-TDP
7
PHLA12-208360-3.0-24-TDP
7
PHLA12-208360-5.0-24-TDP
7
PHLA12-208360-7.5-24-TDP
7
PHLA12-240160-3.0-24-TDP
7
PHLA12-240160-5.0-24-TDP
7
PHLA12-240160-7.5-24-TDP
7
PHLA12-240360-3.0-24-TDP
7
PHLA12-240360-5.0-24-TDP
7
PHLA12-240360-7.5-24-TDP
7
PHLA12-480360-3.0-24-TDP
7
PHLA12-480360-5.0-24-TDP
7
PHLA12-480360-7.5-24-TDP
7
PHLA12-600360-3.0-24-TDP
7
PHLA12-600360-5.0-24-TDP
7
PHLA12-600360-7.5-24-TDP
7
PHLA16-208360-10.0-24-TDP
7
PHLA16-240160-10.0-24-TDP
7
PHLA16-240360-10.0-24-TDP
7
PHLA16-480360-10.0-24-TDP
7
PHLA16-600360-10.0-24-TDP
7
PHLA20-208360-15.0-24-TDP
7
PHLA20-240360-15.0-24-TDP
7
PHLA20-480360-15.0-24-TDP
7
PHLA20-480360-20.0-24-TDP
7
PHLA20-480360-25.0-24-TDP
7
PHLA20-600360-15.0-24-TDP
7
PHLA20-600360-20.0-24-TDP
7
PHLA20-600360-25.0-24-TDP
7
PR 120-277/120 60
PR 120-277/24 60
PR 120-277/240 60
PT3480 35
Q3H5103CA1 16
Q3H5105CA1 16
Q3H5107CA1 16
Q3H5110CA1 16
Q3H5115CA1 16
Q3H5120CA1 16
Q3H5125CA1 16
Q3H5130CA1 16
Q3H5140CA1 16
R3H5103CA1 16
R3H5105CA1 16
R3H5107CA1 16
R3H5110CA1 16
R3H5115CA1 16
R3H5120CA1 16
R3H5125CA1 16
R3H5130CA1 16
R3H5140CA1 16
RCP122 37
RCP122i 37
RCP123 37
RCP123i 37
RCP125 37
RCP125i 37
RCP127 37
RCP127i 37
RCP2202i 37
RCP2203i 37
RCP2205i 37
RCP2207i 37
RCP702 37
RCP703 37
RCP705 37
RCP707 37
RCP802 37
RCP803 37
RCP805 37
RCP807 37
RD5120 15
RD5120 15
RD5150 15
RD5150 15
RD5175 15
RDBT-PD-10 63
RDBT-PD-1000BS 63
RDBT-PD-100BS 63
RDBT-PD-2 63
RDBT-PD-200BS 63
RDBT-PD-3 63
RDBT-PD-300BS 63
RDBT-PD-4 63
RDBT-PD-400BS 63
RDBT-PD-5 63
RDBT-PD-500BS 63
RDBT-PD-6 63
RDBT-PD-600BS 63
RDBT-PD-7 63
RDBT-PD-700BS 63
RDBT-PD-8 63
RDBT-PD-800BS 63
RDBT-PD-9 63
RDBT-PD-900BS 63
RDBT-PDIC 63
RDBT-PDIECL 63
RDBT-PDIECR 63
RDBT-PDOC 63
RFKit-5 85
RFKIT-5 92
RFR-5 85
RFT-1 85
RHG-1012A 77
RHG-1012B 77
RK120EAA 87
RK124EAA 87
RK130EAA 87
RK134EAA 87
RKWP1AA 87
RMF-222-A 69
RMF-222-SS-A 69
RMF-223-SS 69
RMF-342-A 69
RMF-342-SS-A 69
RMF-343-SS 69
RMF-462-A 69
RMF-462-SS-A 69
RMF-463-SS 69
RPH1-5A 81
RPH-208-A 72
RPH22-5Ai 81
RPH22-5ASi 81
RPH-240-A 72
RPH2-5A 81
RPH2-5Ai 81
RPH2-5ASi 81
S2022H10AA 83
S2022H10AB 83
S2025H10AA 83
SB-6* 92
SB6-120-CT 91
SB6-120-T 91
SB-8* 92
SB8-120-CT 91
SB8-120-T 91
SC5100 19
SF200 37
SF400 37
SO 12/4 78
SO 4/3 78
SO 4/4 78
SO 6/4 78
SR120 55
SR120B 55
SR120W 55
SR220 55
SR220B 55
SR220W 55
T1 8
T2 8
T33D052033B30D0F 25
T33D052433B30D0F 25
12
INDEX
Product Index Listing
Model Page Model Page Model Page Model Page
T33D054833B30D0F 25
T4398A1021 85
T46D102433B30D0F 25
T46D104833B30D0F 25
T5100 17
T5100 17
T5102 17
T5122 17
TAT20-480-3/3BB/1T 89
TAT-24-FAN-120V-1 89
TAT-30 89
TAT-45 89
TAT5-208-1/3BB/1T 89
TAT5-240-1/3BB/1T 89
TAT8-208-1/3BB/1T 89
TAT8-240-1/3BB/1T 89
TAT-ILC-25 89
TB3000 34
TB3380 34
TBD 55
TBD-TP 55
TBS 55
TBS-TP 55
TC1602 17
TC1602 22
TC5102 17
TC5102 19
TC5103 17
TF-33 25
TF-46 25
TF-66 25
TF-79 25
TFS5101 17
TFS5101 19
TFS5102 17
TG1 87
TG1B 87
TG2 87
TG2B 87
TG3 87
TG3B 87
TH115-A-024T 86
TH148LE-P 86
TL8230A1003 85
TO-SK-1 76
TSH1TX 81
TSH20J 81
TSH20JW 81
TSH2TX 81
TUH1 13
TW123 17
TW123 / TH5220D 86
TW145 84
TW146 84
TW1510 17
TW1512 17
TW155A 11
TW155A 84
TW255A 11
TW255A 84
U3H2605CA4 21
U3H2607CA4 21
U3H2610CA4 21
U3H2615CA4 21
U3H2620CA4 21
U3U2625CA1 21
U3U2630CA1 21
U3U2640CA1 21
U3U2650CA1 21
U8801050 30
U8802075 30
U8803100 30
U8804125 30
U8805150 30
U8806200 30
UHB-1 13
UHB-3 13
UHB-4 13
UT1001 87
UT3001 87
UT5001 87
UT6001 87
UT8001 87
UT9001 87
V5105 15
V51100 18
V5120 15
V5150 15
VHC-15 70
VHC-15 74
VHC-32 70
VHC-32 74
VMB-41-SS 69
VMB-41-SS 70
W5520/WMK 10
W5550/WMK 10
WWA00 55
WWA01 55
WWA02 55
WWA03 55
WWA04 55
WWA05 55
WWA06 55
WWA07 55
WWA08 55
WWA09 55
YES-1520-3A 78
YES-1524-1A 78
YES-1524-3E 78
YES-1548-3E 78
YES-3048-3A 78