PDPC 01000 0607 104366 Catalog
2014-09-05
: Pdf 104366-Catalog 104366-Catalog 783643 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 940
Download | |
Open PDF In Browser | View PDF |
SPEEDFAXTM 2007–2008 SPEEDFAXTM 2007–2008 Product Catalog Product Catalog power distribution 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com 쏘2007 Siemens Energy & Automation, Inc. All Rights Reserved. Siemens is a registered trademark of Siemens AG. Product names mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice. PDPC-01000-0607 (Supersedes PDPC-01000-0305) 150M0607RDD Printed in USA s Siemens Energy & Automation, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 Residential Commercial Industrial s We offer a wide variety of high quality products and modifications including combination and non-combination starters that are guaranteed for trouble-free operation. Space getting smaller? Siemens switchboards give you room to breathe. integrated modpro ModPro PlusTM means shorter turn-around for standard and modified NEMA control products. Instead of waiting on the factory, our ModPro Plus distributors can turn your order around as quickly as the same day. 쏘2007 Siemens Energy & Automation, Inc. 쏘2007 Siemens Energy & Automation, Inc. When Waiting Is Not An Option, ModPro Plus Delivers. s For more information or to contact a sales representative, call, e-mail, or visit our website. Siemens Energy & Automation, Inc. 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com/modproplus The Siemens integrated power systems switchboard provides a smaller, modular, reliable solution to meet the demanding space needs of the electrical room. Components such as power monitoring, lighting panels, transformers, and lighting control are all incorporated into one piece of equipment. One product, one supplier, and one invoice – it just makes sense. Ask your sales representative about using i-3 Control TechnologyTM in your IPS switchboard design. For more information or to contact a sales representative, call, e-mail, or visit our web site. Siemens Energy & Automation, Inc. 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com s Reliable Products From The Technology Leader Technology Enabling Reliability. When it comes to ready availability, easy installation, and fewer callbacks, you need a manufacturer you can trust. Our products and systems are engineered to take on the most demanding conditions, always available day after day. Combined with a world-class service and maintenance network, complete support is always there, 24/7. RESIDENTIAL For product offerings see Sections 1 – 6 COMMERCIAL For product offerings see Sections 2 – 14 INDUSTRIAL For product offerings see Sections 3 – 16 1 Load Centers 2 Meter Centers 3 Safety Switches 4 Disconnect Switches 5 Enclosed Circuit Breakers 6 Circuit Breakers 7 Transformers 8 Power Monitoring 9 TVSS 10 Panelboards 11 Lighting Controls 12 Switchboards 13 Switchgear 14 Busway Systems 15 Motor Control Centers 16 Control Products 17 Standby Generators 18 Technical 19 Product Index Detailed Table of Contents located at beginning of each section Your single point of contact for general inquiries, customer service, sales office information, and product inquiries: Siemens 24/7 Call Center: 1-800-964-4114 / Email: info.sea@siemens.com / Internet: www.sea.siemens.com Important These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purpose, the matter should be referred to the local Siemens sales office. The contents of this catalog shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty. 1SPEEDFAX TM 2007-2008 Load Centers & Circuit Breakers 1 Contents 1-2 EQ® and Ultimate Series Connected System 1-3 Ultimate™ Load Center Features 1-4 Ultimate™ Load Center Product Offering 1-5 EQ and Ultimate Catalog Numbering System 1-6 ® Load Centers The Ultimate Load Centers 1-7 Value Pack Load Centers 1-8 EQ Small Circuit Load Centers 1-9 EQ Circuit Breaker Enclosures 1-10 EQ 3-Phase Load Centers 1-11 EQ High Ampere (300–400) Load Centers 1-12 Special Application Load Centers 1-13 Riser Panel Load Centers 1-14 Air Conditioning Disconnects 1-15 OEM and Replacement Interiors 1-16 Ultimate MB Load Center Wiring Diagrams 1-17 Ultimate ML Load Center Wiring Diagrams 1-18 EQ 3-Phase Load Center Wiring Diagrams 1-19 EQ High Ampere Load Center Wiring Diagrams 1-20 Ultimate Load Center Knockout Diagrams 1-21 EQ Load Center Outdoor Knockout Diagrams 1-22 EQ Load Center Indoor Knockout Diagrams 1-23 Circuit Breakers Type QP, 1" Breakers 1-24 Type QT, 1/2" Breakers 1-25 Arc Fault and Ground Fault Breakers 1-26 Special Application Breakers 1-27 Type QD, 3/4" Breakers 1-28 Main and Branch Circuit Breakers 1-29 Circuit Breaker Dimension Drawings 1-30 Circuit Breaker Lug Data 1-31 Surge Protection Products 1-32 – 1-34 Load Center and Circuit Breaker Accessories 1-35 – 1-36 All-Sites Temporary Power Outlet Panels 1-37 – 1-38 Temporary Power Outlet Panels, Dimension Drawings 1-39 – 1-45 ™ Residential Commercial Industrial LOAD CENTERS & CIRCUIT BREAKERS EQ® and Ultimate Limited Warranty Program ® EQ and Ultimate Load Centers Limited Warranty Program General LOAD CENTERS & CIRCUIT BREAKERS 1 Siemens Residential Circuit Breaker And Load Center Limited Warranty Program I. Lifetime Limited Warranty on Branch Circuit Breakers (15-225A) Siemens warrants its type QP, QPH, QPP, QT (twin), and HQP branch circuit breakers to be free from defects in material and workmanship under normal care and proper usage in a domestic residential installation, for the lifetime of the Siemens load center in which it is installed. If the circuit breaker fails within the warranty period because of a defect in material or workmanship, Siemens will replace the inoperative breaker free of charge upon return to place of purchase. II. Ten Year Limited Warranty on EQ and Ultimate Load Centers (100-225A) Siemens warrants its type EQ and Ultimate factory installed main breaker and main lug single phase load centers, when used with Siemens circuit breakers described in item I, above, to be free from defects in material and workmanship under normal care and proper usage in a domestic residential installation, for a period of 10 years from the date of installation. If the load center fails within the warranty period because of a defect in material or workmanship, Siemens will, at its option, repair or replace the inoperative part or parts upon return to the place of purchase. III. This warranty applies to the items described in I. and II. above, which were purchased and installed after February 1, 1994. IV. Additional Information Notice requirements and limitations applicable to Siemens warranties are: A. Siemens must be given prompt notice of any defect or failure of any product covered by the warranty. Notice must be accompanied by verification of date of purchase or installation. 1-2 B. Any product authorized for return by Siemens, or its authorized distributors, under this warranty must be sent freight costs prepaid. Siemens will deliver repaired or replaced products to the buyer, freight costs prepaid. Repaired or replaced products shall be warranted for the unexpired portion of the warranty period. C. Any warranties granted or liabilities assumed hereunder will not apply to products that have been damaged, altered, repaired or operated otherwise than in conformity within the requirements for safe operation and maintenance. The Absolute Confidence Warranty™ Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog D. THERE ARE NO OTHER WARRANTIES WHICH EXTEND BEYOND THOSE EXPRESSLY SET FORTH HEREIN AND THIS WARRANTY AND SIEMENS’ OBLIGATIONS AND LIABILITIES HEREUNDER ARE IN LIEU OF, AND SIEMENS DISCLAIMS ALL OTHER WARRANTIES AND GUARANTEES AND ALL OTHER LIABILITIES THEREFORE EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL SIEMENS BE LIABLE FOR ANY OTHER DAMAGES, EITHER DIRECT, INCIDENTAL,CONSEQUENTIAL OR OTHERWISE. E. With respect to products purchased by consumers of the United States for personal use, the implied warranties, including but not limited to the warranties of merchantability and of fitness for a particular purpose, are not excluded but are limited to the duration of the applicable warranty period. Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to buyer. Similarly, some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to buyer. This warranty gives buyer specific legal rights, and buyer may also have other rights which may very from state to state. F. This Warranty covers domestic residential use of Siemens products described in I. and II. above and excludes any commercial applications. ® EQ and Ultimate Load Centers Series-Connected System General Single Family Homes In single family homes, the available fault current normally does not exceed 10,000 amperes. In this situation a load center with a main and branch breakers with interrupting ratings of 10kA, RMS symmetrical will satisfy this Code requirement. In some instances the available fault current may exceed 10,000 amperes but rarely will it exceed 22,000 amperes. In these instances a load center with a main circuit breaker with an interrupting rating of 22kA RMS symmetrical would be required. The branch breakers in method one would be required to be fully rated 22kA breakers while in method two the branch breakers could be 10kA breakers. Apartments, Condominiums, Commercial In larger installations the available fault current will normally be above 10,000 amperes so series combination ratings become much more important. In these installations it is not uncommon to see three breaker series combinations. An example would be 65kA available with an 800 amp service disconnect (MD6 rated 65kA) ahead of a 125 amp feeder disconnect (QPH rated 22kA) ahead of branch breakers in the load center (QP rated 10kA). Series ratings are a part of the rating and marking of the equipment in which the downstream breakers are installed. Section 240.86 of the NEC requires this marking to be on the equipment and the only acceptable combinations in a given device are those combinations marked on the device. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog LOAD CENTERS & CIRCUIT BREAKERS The National Electrical Code states in article 110.9: 110.9 Interrupting Rating. Equipment intended to break current at fault levels shall have an interrupting rating sufficient for the system voltage and the current which is available at the line terminals of the equipment. Equipment intended to break current at other than fault levels shall have an interrupting rating at system voltage sufficient for the current that must be interrupted. There are two ways to satisfy this Code requirement. Either method offers the necessary protection but method two is a less costly alternative to method one. Method one is to select circuit breakers with individual interrupting ratings equal to or greater than the available fault current at the service entrance. Method two is to select circuit breakers with a series combination rating equal to or greater than the available fault current at the service entrance. 1 How Series-Connected Circuit Breakers Save Component Cost 1-3 Ultimate™ Load Centers LOAD CENTERS & CIRCUIT BREAKERS 1 Features The Siemens Ultimate Load Center is the highest quality, most feature rich design in the industry. Features of the Ultimate Load Center include: 1. The patented INSTA-WIRE™ neutral / ground system allows for faster installation because the screws arrive backed out, ready for wire insertion. 1 2 2. The patented Visible neutral / ground system aids in the insertion of conductors. 3. All main lug devices are provided with a factory installed ground bar. 4. Main lug and main breaker panels are provided with split neutrals which can be isolated by removing a tie strap, turning one side into a ground bar. 3 5. Inboard neutrals allow the installation of neutral and ground conductors right next to the breaker. 6. Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws. 7. Combination head screws on the neutrals, grounds, trim, upper pan, and bond screw provide installation flexibility. 8. The patented pre-positioned bond screw eliminates bond strap / screw assemblies, and reduces the risk of losing components in the field. 4 5 6 7 8 9. All devices are convertible from main lug to main breaker or vice versa with the addition of main breaker or main lug kits. 10. All main breakers are straight in wired – no back feeding required. 11. A rigid, sturdy base pan provides the ruggedness required the most harsh applications. 12. The outdoor enclosure has a slide hinge door for the easiest of installation and can be removed by backing out only one screw. 13. All indoor Ultimate Load Centers are invertible for bottom feed applications. 14. Indoor load center trims are now available in white. 11 1-4 10 9 12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13 Ultimate™ Load Centers Product Offering 1 LOAD CENTERS & CIRCUIT BREAKERS The Ultimate Load Center product line provides a wide array of variation to meet any application need. The following offereing is available in the Ultimate product line: ▪ ▪ ▪ ▪ ▪ ▪ ▪ 12-42 Circuits / Spaces Indoor and outdoor enclosures 100 to 225 Amp Main lug and main breaker Two different main lug configurations (see below) Gray or white trim colors Value packs – a mix of branch breakers provided with the load center Main Breaker Panel Other load centers outside the Ultimate product line include: ▪ ▪ ▪ ▪ ▪ ▪ Circuit breaker enclosures Small circuit (2-10) load centers Riser panels for high rise applications 3-Phase load centers High amp load centers (400A) Specialty load centers (generator standby panels, spa panels, renovation panels, and trailer panels) Standard main lug panel with two split neutrals and a factory bonded ground bar (far left) “SG” style main lug panel with an isolated neutral (right) and factory bonded ground bar (left) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-5 ® EQ and Ultimate Load Centers Catalog Numbering System Reference LOAD CENTERS & CIRCUIT BREAKERS 1 Catalog Numbering System G 12 24 MB 1 100 S CU 䊱 䊱 䊱 䊱 䊱 䊱 䊱 䊱 Type Enclosure or Component E G W I R = = = = = Indoor Type 1 2-10 and 30-42 circuits 300-400Amp Indoor Type 1 12-42 circuits Outdoor Type 3R Interior Riser Spaces Maximum number of 1" breakers Circuits Maximum number of circuits Type of Main ML or L = Main Lug MB or B = Main Breaker MC = Convertible System 1 = 1-Phase, 3-Wire 3 = 3-Phase, 3-Wire or 3-Phase, 4-Wire Main Ampere Rating Ex:100 = 100 Amps Trim / Others Blank S F T G or GB = = = = = Combination Surface Flush Feed-Thru Lugs Ground Bar Factory Installed Type of Bus Bar Blank C or CU CP = Aluminum = Copper = Copper Bus, Value Pack Products Shown In Sections 1 and 2 Of This Speedfax Meet Or Exceed The Following Standards. ▪ UL50 — Electric Cabinets and Boxes ▪ UL67 — Electric Panelboards ▪ UL414 — Meter Sockets ▪ UL486 — Wire Connectors ▪ UL489 — Molded-Case Circuit Breakers ▪ UL869 — Service Equipment ▪ UL943 — Ground Fault interrupters (Class A — Personnel Protection) ▪ Federal Specification W-P-115b — Panel Power Distribution ▪ Federal Specification W-C-375B — Circuit Breakers ▪ NEC ▪ NEMA 250 1-6 Underwriters’ Laboratories, Inc. Reference File Numbers: ▪ EQ Meter Combinations (complying with EUSERC specifications) are Listed by UL under file #E10703 ▪ Uni-Pak (complying with EUSERC specifications) are Listed by UL under file #E10703 ▪ Underground pull box (complying with EUSERC specifications) are Listed by UL under file #E10703 ▪ Series Connected Circuit Breaker Information is recognized by UL under file #E10848(N) ▪ Pushmatic Circuit Breakers are Listed by UL under file #E10848 ▪ EQ Load Centers, Uni-Pak and Modular Metering are Listed by UL under file #E10703 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ▪ EQ Load Centers, Uni-Pak and Modular Metering Accessories are UL recognized components found under file #E10703, Volume 6 and 7. (Also referenced under the recognized components directory — section QEUY2) ▪ EQ Circuit Breakers are Listed by UL under file #E82615 ▪ Modular metering disconnects are Listed by UL under file #E25506 ▪ EQ Main Lug Load Centers (where noted) and accessories are Certified by CSA under file #LL85900 The Ultimate Load Centers Single Phase Main Lug and Main Breaker Load Centers Main Breaker/Convertible Load Selection Centers Indoor Enclosure — NEMA Type 1 Max. Aluminum Bus List 2-Pole Catalog Number Price $ Copper Bus Catalog Number List Price $ Enclosure Height (inches) 6 8 10 12 14 12 8 10 12 14 4 10 12 14 20 21 G1224B1100CU G1624B1100CU G2020B1100CU G2424B1100CU G3030B1100CU — — G2030B1150CU — G3030B1150CU — G2040B1200CU — G3040B1200CU G4040B1200CU G4242B1225CU 499.00 546.00 581.00 668.00 733.00 — — 1007.00 — 1093.00 — 1007.00 — 1223.00 1429.00 1697.00 18 21 24 24 30 — 24 30 30 36 — 30 30 36 39 42 G1224B1100 G1624B1100 G2020B1100 — — G2424B1125 G1630B1150 G2030B1150 G2430B1150 G3030B1150 — G2040B1200 G2440B1200 G3040B1200 G4040B1200 — NEW 463.00 499.00 520.00 — — 627.00 863.00 946.00 986.00 1016.00 — 946.00 1004.00 1149.00 1308.00 — Outdoor Enclosure — NEMA Type 3R Enclosure Copper Bus List Height Catalog Number Price $ (inches) W1224B1100CU W1624B1100CU W2020B1100CU — — — — — — — W0816B1200CT W2040B1200CU — W3040B1200CU W4040B1200CU W4242B1225CU 602.00 616.00 642.00 — — — — — — — 925.00 1076.00 — 1366.00 1534.00 1793.00 21 23 29 — — — — — — — 27 29 — 35 38 42 Single phase factory installed 22kA IR main circuit breaker offers 22/10kA IR series combination rating when using 10kA IR Type QP, QT, QPF, QE, QN and QAF branch breakers. Main Lug/Convertible Load Centers Aluminum or Copper Bus 60/75°C Rated 100,000A IR 12-42 Circuits / 125-225 Amperes Branch Circuits Main Ampere Max No. of 1-Pole Rating Spaces Circuits 1-Phase, 3-Wire SN 125 12 12 125 12 24 125 16 24 125 20 20 125 24 24 125 24 40 125 30 40 125 40 40 150 20 30 200 8 16 200 12 24 200 20 40 200 24 40 200 30 30 200 30 40 200 40 40 225 12 24 225 42 42 Indoor Enclosure — NEMA Type 1 Max. Aluminum Bus List 2-Pole Catalog Number Price $ 6 6 8 10 12 12 14 20 10 4 6 10 12 14 14 20 6 21 G1212L1125 G1224L1125 G1624L1125 G2020L1125 G2424L1125 — — — G2030L1150 — — G2040L1200 G2440L1200 G3030L1200 G3040L1200 G4040L1200 — — 194.00 253.00 309.00 361.00 410.00 — — — 437.00 — — 532.00 563.00 545.00 605.00 905.00 — — Copper Bus Catalog Number List Price $ G1212L1125CU 230.00 G1224L1125CU 290.00 G1624L1125CU 358.00 G2020L1125CU 424.00 — — G2440L1125CU 470.00 G3040L1125CU 534.00 G4040L1125CU NEW — G2030L1150CU 486.00 — — G1224L1200CU 424.00 G2040L1200CU 591.00 G2440L1200CU 624.00 G3030L1200CU 627.00 G3040L1200CU 681.00 G4040L1200CU 1004.00 — — G4242L1225CU 1029.00 Enclosure Height (inches) 21 21 21 24 30 30 30 39 30 — 24 30 30 36 36 39 — 42 Outdoor Enclosure — NEMA Type 3R Enclosure Copper Bus List Height Catalog Number Price $ (inches) W1212L1125CU 302.00 W1224L1125CU 379.00 W1624L1125CU 463.00 — — W2424L1125CU NEW 560.00 — — W3040L1125CU 685.00 — — W2030L1150CU 595.00 W0816L1200CT 494.00 W1224L1200CU 518.00 W2040L1200CU 705.00 — — — — W3040L1200CU 778.00 W4040L1200CU 1086.00 W1224L1225CU NEW 685.00 W4242L1225CU 1411.00 SG Series Main Lug/Convertible Load Centers Aluminum or Copper Bus 60/75°C Rated 100,000A IR 12-40 Circuits / 125-200 Amperes Branch Circuits Main Ampere Max No. of 1-Pole Rating Spaces Circuits 1-Phase, 3-Wire SN 125 12 24 125 16 24 125 20 30 125 24 30 150 20 30 200 30 40 200 40 40 Suitable for use as service entrance equipment. May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. See equipment markings. Indoor enclosures are 14 5/16" wide by 3 15/16" deep. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. 125A load centers will accept MBK100A and MBK125A 150A load centers will accept MBK150A 200A load centers will accept MBK150A and MBK200A 225A load centers will accept MBK150A, MBK200A, and MBK225A. Discount Schedule RESI 21 21 23 — 27 — 35 — 29 27 27 29 — — 35 38 29 42 Indoor Enclosure — NEMA Type 1 Max. 2-Pole Copper Bus Catalog Number List Price $ Enclosure Height (inches) 6 8 10 12 10 14 20 G1224L1125CUSG G1624L1125CUSG G2030L1125CUSG G2430L1125CUSG G2030L1150CUSG G3040L1200CUSG G4040L1200CUSG 290.00 358.00 424.00 433.00 486.00 681.00 1004.00 21 24 24 30 30 36 39 Suitable for use as service entrance equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance branch circuit panelboard. See article 408.14 of the NEC®. Factory installed 100% neutral with factory bonded 100% ground. No neutral tie strap. All 225 amp load centers are provided with tin plated copper bus bars. Copper bus load centers are recommended for those applications where the environment may be severe (i.e. farm and coastal areas). NEW Adding a “W” to the end of the load center catalog number (example: G3040L1200CUW) will change the trim color to white. Slight price increase as well as a 2-3 week lead time required. Pallet quantities only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-7 LOAD CENTERS & CIRCUIT BREAKERS Branch Circuits Main Ampere Max No. of 1-Pole Rating Spaces Circuits 1-Phase, 3-Wire SN 100 12 24 100 16 24 100 20 20 100 24 24 100 30 30 125 24 24 150 16 30 150 20 30 150 24 30 150 30 30 200 8 16 200 20 40 200 24 40 200 30 40 200 40 40 225 42 42 1 Aluminum or Copper Bus 60/75°C Rated 22,000A IR 12-42 Circuits / 100-225 Amperes The Ultimate Load Centers Value Pack Load Centers햳 Selection LOAD CENTERS & CIRCUIT BREAKERS 1 햴 Value pack load centers offer a standard load center and an assortment of branch breakers . The offering of value packs and the breakers included are listed in the table below. Catalog Number Load Center Breakers Included G2020B1100CP G3030B1100CP G1224L1125CP G1624L1125CP G3030B1150CP G3040B1200CP G3040B1200CPP G3040L1200CP G3040L1200CPP G3040L1200CP1 G4040B1200CP G4040B1200CPP G4040B1200CP1 G4040B1200CUSGP G4040L1200CPP W3040B1200CP W3040L1200CP W4040B1200CP W4040L1200CP G2020B1100CU G3030B1100CU G1224L1125CU G1624L1125CU G3030B1150CU G3040B1200CU G3040B1200CU G3040L1200CU G3040L1200CU G3040L1200CU G4040B1200CU G4040B1200CU G4040B1200CU G4040L1200CUSG G4040L1200CU W3040B1200CU W3040L1200CU W4040B1200CU W4040L1200CU (6) Q120 (6) Q120, (6) Q115 (6) Q120 (6) Q120 (6) Q120, (1) Q230, (1) Q250 (6) Q120, (1) Q230, (1) Q250 (6) Q120, (1) Q230, (1) Q240 (6) Q120, (1) Q230, (1) Q250 (6) Q120, (1) Q230, (1) Q240 (6) Q120, (6) Q115, (1) Q230, (1) Q250 (6) Q120, (1) Q230, (1) Q250 (6) Q120, (1) Q230, (1) Q240 (6) Q115, (6) Q120, (1) Q230, (1) Q250 MBK200A햲, (6) Q120, (1) Q230, (1) Q250 (6) Q120, (1) Q230, (1) Q240 (6) Q120, (6) Q115, (1) Q230, (1) Q250 (6) Q120, (6) Q115, (1) Q230, (1) Q250 (6) Q120, (6) Q115, (1) Q230, (1) Q250 (6) Q120, (1) Q230, (1) Q250 NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW List Price $ 659.00 900.00 432.00 468.00 1323.00 1415.00 1415.00 928.00 964.00 1061.00 1631.00 1429.00 1759.00 1698.00 1004.00 1613.00 1025.00 1780.00 1331.00 Ultimate Load Center Accessories햶 Catalog Number Description ECHS000 ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 ECGB5 ECGB10 MBK100A햷 MBK125A햷 MBK150A햷 MBK200A햷 MBK225A햷 ECLKB1햸 ECLK1-2 ECLK2 ECQFL2 ECCP1 ECTS2 ECQF3 Hub cover plate 3 ⁄4" Hub 1" Hub 11⁄4" Hub 11⁄2" Hub 2" Hub 21⁄2" Hub 5 pos ground bar 10 pos ground bar 100A main breaker kit 125A main breaker kit 150A main breaker kit 200A main breaker kit 225A main breaker kit 2/0 lug kit with bonding means for Ultimate load centers #2-1/0 neutral lug #4-2/0 neutral lug Door lock Directory cards Trim screws Filler plates Notes: 햲 MBK200A factory installed. 햳 All value packs provided with copper bus bars. 햴 Breakers are shipped inside a sleeve located in the load center. 햵 “New” items to be available Spring 2007. 햶 See accessory pages at end of section for complete accessory listing. 햷 MBK100A only for use on 100 or 125A load centers / MBK125A only for use on 125A load centers / MBK150A only for use on 150A, 200 or 225A load centers / MBK200A only for use on 200 or 225A load centers / MBK225A only for use on 225A load centers. 햸 List Price $ Pack Qty. 38.00 39.50 39.50 39.50 39.50 69.00 109.00 18.40 21.00 230.00 473.00 588.00 588.00 588.00 26.50 13.90 18.40 89.00 616.00 9.80 14.20 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 100 6 5 ECLKB1 installed on left side neutral bar when the tie strap is removed. A tang is provided allowing that lug and neutral assembly to be bonded to the enclosure. Ultimate Load Center Lug Data Terminals A, B, N 햲 A, B, N 햳 ,G Neutral-Ground Bars (Use Type GB Ground Bar Accessory Kit) Ground Conductors Only Main Lug/Main Breaker to Bus Connection (1/4-20 nut) Bonding Screw 햲 햳 Wire 300 kcmil-4 AWG 2/0-4 AWG 10–14 Cu/10–12 Al 8 AWG 6–4 AWG (2) or (3) 14 AWG (2) 12–10 AWG Torque 275 lb.-ins. 110 lb.-ins. 20 lb.-ins. 25 lb.-ins. 35 lb.-ins. 20 lb.-ins. 20 lb.-ins. 45 lb.-ins. 45 lb.-ins. 150, 200 & 225 amp load centers. 100 & 125 amp load centers. 1-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI ® EQ Load Centers Small Circuit Load Centers Selection/Wiring Diagrams 1 100,000A IR LOAD CENTERS & CIRCUIT BREAKERS 4–16 circuits, 100–125 Amperes 1-Phase, 3-Wire, SN 120/240 Volts AC Features/Applications EQ Load Centers with main lugs feature a combination trim box in one package. ▪ Interiors offer removal in seconds ▪ Single phase ▪ One piece bus bar construction designed for use only with circuit breakers ▪ UL Listed ▪ UL listed on 60/75°C conductors (see equipment markings for applications) ▪ Positive load side circuit breaker hook rails ▪ Outdoor Type 3R devices use HS Type hubs E0408ML1125(F,S) E0816ML1125(F,S)CU Main Lugs with Aluminum Bus 햷 Branch Circuits Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R Max. 1-Pole QP Amp No. of No. of Max. Rating Spaces Circuits 2-Poles Catalog Number — Replace Suffix F (Flush) with S for Surface Mounting Dimensions List Std. (inches) Price $ Pkg. H W Catalog Number 100 12 24 6 E1224ML1100FG햲 261.00 1 14 3/4 12 3/8 3 7/8 — 125 4 8 2 E0408ML1125F 햳햵햶 81.00 5 12 5/8 6 5/8 3 1/2 W0408ML1125 햳햴햵 125 4 8 2 — — — — — — 125 4 8 2 — — — — — — 125 8 16 4 E0816ML1125F 햶 145.00 1 D Dimensions Std. (inches) Pkg. H W D — — — — 150.00 5 12 1/4 6 4 1/4 W0408L1125SPA50 햴햵햹 600.00 1 12 1/4 6 4 1/4 W0408L1125SPA60 햴햵햹 630.00 1 12 1/4 6 4 1/4 — — — — — List Price $ — 14 3/4 12 3/8 3 7/8 — Main Lug and Main Breaker with Copper Bus 햷햺 100,000A IR 4–16 circuits, 100–225 Amperes 1-Phase, 3-Wire, SN 120/240 Volts AC Features Branch Circuits Indoor Enclosure — NEMA Type 1 Max. 1-Pole QP Amp No. of No. of Max. Catalog Rating Spaces Circuits 2-Poles Number List Price $ Outdoor Enclosure — NEMA Type 3R Dimensions Std. (inches) Pkg. H W D Catalog Number List Price $ Dimensions Std. (inches) Pkg. H W D — 100 10 20 4 E1020MB1100FCGP 햸 햽 494.00 1 14 3/4 12 3/8 3 7/8 — 100 12 24 6 E1224ML1100FCU 265.00 1 14 3/4 12 3/8 3 7/8 — — 125 8 16 4 E0816ML1125FCU햶 158.00 1 14 3/4 12 3/8 3 7/8 W0816ML1125CU햶 264.00 125 8 16 4 E0816ML1125SCU 154.00 1 14 3/4 12 3/8 3 7/8 — — — — — 225 4 6 2 — — 1 — — — W0406ML1225CU햳 396.00 1 23 10 4 1/8 200 4 4 2 — — 1 — — — W0404MB1200CT햻햽 823.00 1 20 11 1/8 4 3/4 — — — — — — — — — 1 14 3/4 12 1/8 4 1/4 Wiring Diagrams E0816ML1125 W0816ML1125CU 16-Poles Max. E0408ML1125 W0408ML1125 8-Poles Max. 햲 햳 70 amp maximum breaker. Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. 햴 Suitable for use as service equipment when a main breaker (100A maximum) is back-fed in a branch position and used with main breaker retainer clip (Cat. No. ECMBR1). 햵 100 amp maximum breaker. Discount Schedule RESI 햶 E1224ML1100FG 24-Poles Max. Suitable for use as service entrance equipment when a main breaker (125A maximum) is back-fed in a branch position and used with main breaker retainer clip (Cat. No. ECMBR1). 햷 Suitable for use as service entrance when not more than six main disconnecting means are provided, and when not used as lighting and appliance branch circuit panelboard. Check local codes and restrictions. 햸 Two Q115 and one Q230 breaker included. 햹 W0408L1125SPA50 provided with factory installed QF50 and ground bar. W0408L1125SPA60 provided with factory installed QF260 and ground bar. 햺 Copper Bus load centers are recommended for those applications where the environment may be severe (i.e. farm and coastal areas). 햻 2" HS Type hub provided. 햽 Type QNR main breaker factory installed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-9 ® EQ Load Centers LOAD CENTERS & CIRCUIT BREAKERS 1 Circuit Breakers Enclosures Selection/Wiring Diagrams E0303ML3100CU W0202MB1200CU Features ▪ Circuit breaker enclosures range from 60A to 225A, indoor and outdoor models ▪ Designed for use exclusively with QP, QT, QPH, HQP, BQ, BQH, HBQ, QPP, QPPH, HQPP, QJ2, QJH2 and QJ2-H circuit breakers ▪ UL listed ▪ Suitable for use as service entrance equipment ▪ UL listed for 60/75°C conductors (See equipment markings for applications) Breaker Used Frame Type Indoor Enclosure — NEMA Type 1 Ampere No. of Catalog Rating Poles Number List Price $ Outdoor Enclosure — NEMA Type 3R Std. Pkg. Dimensions (inches) Catalog Height Width Depth Number List Price $ Std. Dimensions (inches) Pkg. Height Width Depth W0204ML1060 햲 — W0202MB1100CU 햵 W0204ML1125CU 141.00 — 364.00 189.00 5 — 1 1 18 — 17.4 17 1/8 15 — 7.3 17 3/8 4 1/4 — 4.3 4 5/16 1-Phase, 3-Wire SN — 120/240 Volts AC QP, QPH, HQP 60 60 100 125 2 2 2 E0204ML1060S 햲 E0204ML1060F 햵 E0202MB1100 NEW E0204ML1125SCU 76.00 116.00 306.00 121.00 5 5 1 1 9 9 17 17 QN, QNH, HQN 200 200 2 2 —��� E0202MB1200 NEW — 718.00 — — — 19 3/8 — 8 1/2 — 4 W0202ML1200CU W0202MB1200CU 햵 468.00 902.00 1 1 19 3/4 19 3/4 18.4 18.4 4.6 4.6 QPP, QPPH, HQPP, QP 225 1-4 — — — — — — W0406ML1225CU 햳 396.00 1 23 10 4 1/8 QJ2, QJH2, QJ2-H 150 200 225 2 2 2 — — — — — — — — — — — — — — — — — — WB2150B 햶 WB2200B 햶 WB2225 햳 949.00 949.00 418.00 1 1 1 27 27 27 17 3/8 17 3/8 17 3/8 4 15/16 4 15/16 4 5/16 7/8 7/8 1/8 1/8 5 5 7 7 1/8 1/8 3/8 1/8 2 2 4 4 5/8 5/8 5/16 1/4 3-Phase, 3-Wire 240 Volts AC or 3-Phase, 4-Wire SN — 120/208 Volts AC, 120/240, 240 Volts AC 2-3 E0303ML3100S 햴 189.00 1 17 1/8 7 1/8 4 1/4 W0303ML3100 햴 249.00 1 17 1/8 17 3/8 4 5/16 BQ, BQH, HBQ 100 2-3 EB3100S 햴 189.00 1 17 1/8 7 1/8 4 1/4 WB3100 햴 249.00 1 17 1/8 17 3/8 4 5/16 QJ2, QJH2, QJ2-H 2-3 EB3225F 햳 226.00 1 27111 10 1/8 5 1/8 WB3225 햳 459.00 1 27 10 1/8 5 9/16 QP, QPH,HQP 100 햲 햳 225 Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. 42,000A IR maximum. Copper wire only at 225A. 햴 햵 Will not accommodate GFCI or circuit breaker with shunt trip. Main breaker factory installed. 햶 QJ2 frame circuit breaker installed, rated 10,000A IR. Wiring Diagrams 1-Phase, 3-Wire 3-Phase, 4-Wire E0303ML3100CU EB3100 W0303ML3100CU WB3100 EB3225 WB3225 2 or 3-Pole E0204ML1060 W0204ML1060 1 or 2-Poles 1-10 E0204ML1125FCU W0204ML1125CU 1 or 2-Poles WB2225 One 2-Pole W0406ML1225CU 1 or 2-Poles Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI ® EQ Load Centers 3-Phase Main Breaker with Copper Bus햵햶 Selection 10,000A IR 햲 햴 1 LOAD CENTERS & CIRCUIT BREAKERS 30–42 Circuits, 100–225 Amperes 3-Phase, 3-Wire, 240 Volt AC — or — 3-Phase, 4-Wire 120/240 – or – 120/208 Volts AC W3042L3200CU G3042B3200CU Branch Circuits Indoor Enclosure — NEMA Type 1 Max. Ampere 1-Pole No. No. of Max. Catalog Rating of Spaces Circuits 2-Poles Number Outdoor Enclosure — NEMA Type 3R List Prices $ Dimensions (inches) Height Width Depth Catalog Number List Prices $ Dimensions (inches) Height Width Depth 100 30 30 14 G3030B3100CU햳 1288.00 30 14 3/8 3 15/16 — — — — 150 24 42 14 G2442B3150CU 2112.00 36 14 3/8 3 15/16 W2442B3150CU 2301.00 34 14 1/4 4 1/2 200 30 42 14 G3042B3200CU 2209.00 36 14 3/8 3 15/16 W3042B3200CU 2393.00 37 14 1/4 4 1/2 200 42 42 20 G4242B3200CU 2326.00 42 14 3/8 3 15/16 W4242B3200CU 2639.00 43 14 1/4 4 1/2 225 42 42 20 G4242B3225CU 2326.00 42 14 3/8 3 15/16 W4242B3225CU 2639.00 43 14 1/4 4 1/2 햲 햳 May be installed on higher rated systems when protected by a circuit breaker with a higher A IR rating. See equipment markings. Back-fed main breaker. When 22,000 IR or 42,000 IR main circuit breakers are required, add the suffix “-22” or “-42” respectively. List price adder applies. 햵 Standard Package Quality = 1. 햶 — Copper bus load centers are recommended for those applications where the environment may be severe (i.e. farm and coastal areas) or where a premium panel is desired. 3-Phase Main Lug with Copper Bus햴햵 100,000A IR 12–42 circuits, 125–225 Amperes 3-Phase, 3-Wire, 240 Volt AC — or — 3-Phase, 4-Wire SN 120/240 – or – 120/208 Volts AC Branch Circuits Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R Max. Amp 1-Pole No. Rating of Spaces 125 12 150 18 150 24 200 12 200 18 200 24 200 30 No. of Circuits 24 36 42 24 36 42 42 Max. 2-Poles 6 9 12 6 8 12 14 Catalog Number G1224L3125CU햲햳 G1836L3150CU햲햳 G2442L3150CU햳 G1224L3200CU햳 G1836L3200CU G2442L3200CU햳 G3042L3200CU햳 List Price $ 390.00 537.00 648.00 520.00 621.00 720.00 767.00 Dimensions (inches) Height Width 21 14 3/8 24 14 3/8 30 14 3/8 24 14 3/8 30 14 3/8 30 14 3/8 36 14 3/8 225 42 20 G4242L3225CU햳 977.00 42 햲 42 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance branch circuit panelboard. See article 408 of the NEC. 햳 햴 Depth 3 15/16 3 15/16 3 15/16 3 15/16 3 15/16 3 15/16 3 15/16 Catalog Number W1224L3125CU햲햳 W1836L3150CU햲햳 W2442L3150CU햳 W1224L3200CU햲햳 — W2442L3200CU햳 W3042L3200CU햳 14 3/8 3 15/16 W4242L3225CU햳 Suitable for use as service equipment when a main breaker (100A maximum) is back-fed in a branch position, and used with main breaker retainer clip (Cat. No. MBR-1). Standard Package Quantity = 1. 햵 List Price $ 532.00 685.00 859.00 666.00 — 859.00 909.00 Dimensions (inches) Height Width 21 — 25 14 1/4 28 14 1/4 22 14 1/4 — — 31 14 1/4 34 14 1/4 1612.00 42 Depth — 4 1/2 4 1/2 4 1/2 — 4 1/2 4 1/2 14 1/4 4 1/2 Copper bus load centers are recommended for those applications where the environment may be severe (i.e. farm and coastal areas) or where a premium panel is desired. Lug Data 3-Phase Load Centers Terminals A, B, C N햲 A, B, C & N 햴 N햳 G햲 Branch Breakers Type “LK” Subfeed Lug Kit 햲 햳 Wire See Marking on Breaker 250 kcmil-4 AWG 300 kcmil-6 AWG 2/0-4 AWG 2/0-4 AWG See Marking on Breaker See Marking on Lug Kit 150, 200 & 225 amp load centers. 100 & 125 amp load centers. Discount Schedule RESI Torque 340 340 135 45 lb.-ins. lb.-ins. lb.-ins. lb.-ins. Terminals Neutral-Ground (Use Type GB Ground Bar Kit Accessory) Ground Conductors Only LK1-2 (Accessory) LK2 (Accessory) LK3 (Accessory) 햴 Wire 14 –10 AWG 8 AWG 6 AWG 4 AWG (2) or (3) 14–10 AWG 2/0-2 AWG 2/0-4 AWG 300 kcmil-1 AWG Torque 20 lb.-ins. 25 lb.-ins. 35 lb.-ins. 45 lb.-ins. 20 lb.-ins. 45 lb.-ins. 135 lb.-ins. 340 lb.-ins. Main lug load centers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-11 ® EQ Load Centers LOAD CENTERS & CIRCUIT BREAKERS 1 Main Breaker햲 Selection E3030MB1400SCU 300– 400 Ampere Features ▪ UL listed for 60/75°C conductors. See equipment markings for applications. ▪ Copper bus standard. ▪ Factory installed lock on indoor enclosure. 1ø, 3-Wire 120/240 Volts AC Branch Circuits Indoor Enclosure — NEMA Type 1 (22,000A IR)햳 Type QP Ampere Rating 300 300 400 400 400 Max. 1-Pole 42 42 30 42 42 Max. 2-Poles 20 20 14 20 20 Catalog Number 햴 E4242MB1300FCU E4242MB1300SCU E3030MB1400SCU E4242MB1400FCU E4242MB1400SCU List Price $ 6263.00 6263.00 5751.00 6263.00 6263.00 Std. Pkg. 1 1 1 1 1 Dimensions (inches) Height Width Depth 58 20 6 58 20 6 52 20 6 58 20 6 58 20 6 Outdoor Enclosure — NEMA Type 3R (22,000A IR)햳 Trim Style Flush Surface Surface Flush Surface Catalog Number — — W3030MB1400CU W4242MB1400CU — List Price $ — — 6800.00 7408.00 — Std. Pkg. — — 1 1 — Dimensions (inches) Height Width Depth햵 — — — — — — 52 20 6 58 20 6 — — — 3ø, 3-Wire 240 Volts AC — or — 3-Phase, 4-Wire SN, 120/208 Volts AC Branch Circuits Indoor Enclosure — NEMA Type 1 (22,000A IR)햳 Type QP Ampere Rating 300 400 400 400 Max. Max. 1-Pole 2-Poles 42 20 30 14 42 20 42 20 Catalog List Number 햴 Price $ E4242MB3300SCU 6601.00 E3030MB3400SCU 5956.00 E4242MB3400FCU 6601.00 E4242MB3400SCU 6601.00 Std. Pkg. 1 1 1 1 Dimensions (inches) Height Width Depth 58 20 6 52 20 6 58 20 6 58 20 6 Outdoor Enclosure — NEMA Type 3R (22,000A IR)햳 Trim Style Surface Surface Flush Surface Catalog Number — — W4242MB3400CU — List Price $ — — 7672.00 — Std. Pkg. — — 1 — Dimensions (inches) Height Width Depth햵 — — — — — — 58 20 6 — — — Main Lug 400 Ampere 1ø, 3-Wire 120/240 Volts AC Branch Circuits Indoor Enclosure — NEMA Type 1 (22,000A IR) Type QP Ampere Rating 400 400 400 400 Max. Max. Catalog 1-Pole 2-Poles Number 햴 24 12 — 30 14 E3030ML1400SCU 42 20 E4242ML1400SCU 42 20 E4242ML1400FCU List Price $ — 1871.00 2066.00 2066.00 Std. Pkg. — 1 1 1 Dimensions (inches) Height Width Depth — — — 41 20 6 47 20 6 47 20 6 Outdoor Enclosure — NEMA Type 3R (22,000A IR) Trim Style — Surface Surface Flush Catalog Number W0606ML1400CU햶햷 W3030ML1400CU — W4242ML1400CU List Price $ 2275.00 2590.00 — 2777.00 Std. Pkg. 1 1 — 1 Dimensions (inches) Height Width Depth햵 43 20 6 43 20 6 — — — 47 20 6 3ø, 3-Wire 240 Volts AC — or — 3-Phase, 4-Wire SN, 120/208 Volts AC Branch Circuits Indoor Enclosure — NEMA Type 1 (22,000A IR)햳 Type QP Ampere Rating 400 400 400 햲 햳 햴 Max. Max. 1-Pole 2-Poles 30 14 42 20 42 20 Catalog Number E3030ML3400SCU E4242ML3400FCU E4242ML3400SCU UL listed as suitable for use as service equipment. 65,000A IR on 600A. Where noted suffix S = Surface, F = Flush. 1-12 List Price $ 2050.00 2134.00 2134.00 햵 햶 Std. Pkg. 1 1 1 Dimensions (inches) Height Width Depth 41 20 6 47 20 6 47 20 6 Outdoor Enclosure — NEMA Type 3R (22,000A IR)햳 Trim Catalog Style Number Surface — Flush W4242ML3400CU Surface — Does not include 2" rainhead overhang. Accepts up to six QN style breakers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햷 List Price $ — 2850.00 — Std. Pkg. — 1 — Dimensions (inches) Height Width Depth햵 — — — 47 20 6 — — — Suitable for use as service entrance equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard. Discount Schedule RESI Load Centers Special Application Load Centers Selection 1 Renovation Panel These panels feature two back-fed main breakers that are mechanically interlocked to allow only one main breaker to be “on” at a time. Additional branch circuit spaces allow critical circuits to be controlled through this panel. Ideal for older home renovation projects where the distance between the studs is narrower than current construction practices. The narrower panel eliminates the need to ‘notch’ out the existing studs. Trailer Panels Spa Panels These feed-through panels are UL listed as Service Equipment and are ideal for serving mobile homes located on private lots. The panels either have factory or field added main breakers with subfeed lugs. Additional breaker positions allow connection of external circuits such as lights, pumps, etc. Spa Panels are ideal for outdoor applications requiring the use of ground fault protection, such as hot tubs. A factory installed 2-Pole GFCI breaker is provided, along with 2 extra circuits. Spa Panels Main Amp 125 125 No. of Spaces햶 2 2 Max. Circuits 4 4 Catalog Number W0408L1125SPA50햺 W0408L1125SPA60햻 Height 121⁄4 121⁄4 Dimensions햳 Width Depth 161⁄8 41⁄4 161⁄8 41⁄4 List Price $ 600.00 630.00 Dimensions햳 Width Depth 123⁄8 37⁄8 123⁄8 37⁄8 List Price $ 494.00 265.00 Renovation Panels - 3-Wire 120/240V AC Main Amp 100 100 No. of Spaces햶 10 12 Max. Circuits 20 24 Catalog Number E1020MB1100FCGP햾 E1224ML1100FCU Height 143⁄4 143⁄4 Standby Power Panels - 3-Wire 120/240V AC햿 Utility Main 60 100 100 Generator No. of Main Spaces햶 60 12 60 12 60 12 Max. Circuits 24 24 24 Indoor Type 1 Catalog Number G1224B6060GC햷 G1224B10060GC햷 W1224B10060GC햸 Height 21 21 21 Dimensions햳 Width Depth 143⁄8 4 3 14 ⁄8 4 3 14 ⁄8 4 List Price $ 758.00 945.00 1139.00 Outdoor햲 Trailer Panels - 120/240V AC 208Y/120V AC Amps Max 200 200 200 햲 햳 햴 햵 No. of Spaces 4 8 8 Max. Circuits 8 16 16 Indoor Type 1 Catalog Number W0404MB1200CT햵햽 W0816L1200CT햴 W0816B1200CT햴햽 HS hub provision provided. Closure plate included. Dimensions shown are representative of outside box length, width, and depth and do not include allowances for mounting bumps, endwalls, covers, hubs, or hardware protrusions. Dimensions are subject to change. For Main breaker applications, field - add an MBK150A or MBK200A. W0404MB1200CT shipped with ECHS200 hub instead of closure plate. Discount Schedule RESI 햶 햷 햸 햹 햺 햻 Height 20 29 29 Dimensions햳 Width Depth 111⁄8 43⁄4 1 14 ⁄4 41⁄2 141⁄4 41⁄2 Main Breaker QN2200R MBK MBK200A These branch breaker provisions are in addition to the two factory installed main breakers. Indoor Type 1 Enclosure. Outdoor Type 3R Enclosure. Two Q115 and one Q230 provided. 50 Amp, 2-pole GFCI breaker installed. 60 Amp, 2-pole GFCI breaker installed. Factory Field Factory 햽 햾 햿 List Price $ 823.00 494.00 925.00 200A factory installed main breaker included. 100A factory installed main breaker included. NEW ..........See Standby Generator Section 17 for a complete line of manual transfer interlock kits which can convert most load centers and meter combinations into standby power panels. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-13 LOAD CENTERS & CIRCUIT BREAKERS Standby Power Panels EQ® Load Centers LOAD CENTERS & CIRCUIT BREAKERS 1 Riser Panel Load Centers Riser Panel Load Centers are ideal for high rise applications. The shifted interior provides room for conductors to pass through the load center햲. The tap kits allow the installer to tap off from those conductors to power the panel.햳 Features Selection The Riser Gutter Tap Kit (ECRLK250) allows the installer to tap off of the main conductors, eliminating the need to cut completely through the conductor. The tap kit accepts 250-1/0 on the main conductor side and 250-6 on the tap side. One ECRLK250 comes with 3 lug kits. ▪ UL Listed from main lug to main ▪ Convertible breaker햴 ▪ Easily removable interior ▪ Copper bus bars The Riser Gutter (RAG24) is used to convert any load center 24" or larger into a riser panel. Features ▪ UL Listed ▪ Single and 3-phase applications ▪ Compatible with any single or 3-phase Siemens load center 24" or higher ▪ Flush trim included ▪ Load center mounting hardware and pass thru bushing included ▪ Catalog number — RAG24 Trim/Cover RAG24 R2040ML1125CU Door On R2040ML1125CU ECRLK250 Amp Rating Max 1-pole No. of Spaces No. of Circuits QP Max. 2-Poles Catalog Number 125 12 24 6 125 20 40 10 Notes: 1. The riser panels are single phase only, but can be fed from single or 3-phase systems running through the gutter trough area. 1-14 Dimensions List Price $ H W D R1224ML1125CU 465.00 18 141⁄4 4 R2040ML1125CU 550.00 24 141⁄4 4 2. Tap lug kits not included. 3. Use main breaker kit MBK125. 4. Use ECGB series of ground bars for field grounds. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI AC Disconnects 1-Phase, NEMA 3R Rated Selection 1 LOAD CENTERS & CIRCUIT BREAKERS WN2060 WF2060PL WN2060GFCI WNAS2060GFCI Steel AC Disconnects Ampere Rating 30 60 60 60 Disconnect Type Fused Pullout Fused Pullout Non-fused Pullout Non-automatic Switch Catalog Number WF2030 WF2060 WN2060 WNAS2060 Horse Power Rating 3 10 10 10 Height 71⁄4 9 71⁄4 71⁄4 Dimensions Width Depth 5 21⁄8 5 21⁄8 5 21⁄8 5 21⁄8 List Price $ 145.00 145.00 145.00 173.00 Pallet Qty. 360 360 360 360 Catalog Number WF2030PL WF2060PL WN2060PL WN2060PLX WNAS2060PL Horse Power Rating 3 10 10 10 10 Height 71⁄4 71⁄4 71⁄4 8 71⁄4 Dimensions Width Depth 5 21⁄2 5 21⁄2 5 21⁄2 53⁄4 31⁄2 5 21⁄2 List Price $ 221.00 221.00 201.00 211.00 201.00 Pallet Qty. 216 216 360 288 360 Height 9 9 71⁄8 71⁄8 Dimensions Width Depth 61⁄8 53⁄16 1 6 ⁄8 53⁄16 53⁄4 53⁄16 53⁄4 53⁄16 List Price $ 471.00 471.00 436.00 471.00 Pallet Qty. 112 112 144 144 Plastic AC Disconnects Ampere Rating 30 60 60 60 NEW 60 NEW Disconnect Type Fused Pullout Fused Pullout Non-fused Pullout Non-Fused Pullout Non-automatic switch Steel AC Disconnects with 15 Amp GFCI Receptacle Ampere Rating 30 60 60 60 Disconnect Type Fused Pullout Fused Pullout Non-fused Pullout Non-automatic Switch Catalog Number WF2030GFCI WF2060GFCI WN2060GFCI WNAS2060GFCI Horse Power Rating 3 10 10 10 Wire Range Table Connector Line Load Neutral Equip. Grnd Copper Solid Stranded #14-8 #14-3 #14-8 #14-3 #12-8 #12-2 #12-8 #12-2 Aluminum Solid Stranded #12-8 #12-3 #12-8 #12-3 #12-8 #12-2 #12-8 #12-2 Add a “BP” to the end of the catalog number to order in pallet quantites, example: WN2060BP. Accepts Class H Fuse Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-15 Load Centers Load Center replacement and OEM Interiors Selection LOAD CENTERS & CIRCUIT BREAKERS 1 1ø: Small Circuit Main Lug Interiors Amps 60 60 125 125 125 200 200 Catalog Number햳 I0204ML1125 I0303ML3100 I0408ML1125 I0816ML1125CU I0816ML1125CUSP I0202L1200 I1220L1200CT Spaces 2 3 4 8 8 4 12 Dimensions Height Width 5.06 2.12 5.06 3.12 4.51 6.61 6.19 6.81 6.19 6.81 3.88 7.13 9.00 7.00 Circuits 2 3 8 16 16 4 20 List Price $ 31.50 59.00 57.00 109.00 109.00 67.00 165.00 W W H H Ultimate 1ø: High Circuit Main Lug Interiors with Neutral Bars햵 Amps 125 125 125 200 200 200 200 200 200 225 Catalog Number햳 I1224L1125CU I1624L1125CU I3040L1125CU I0816L1200CT햵 I1224L1200CU I1632L1200CU I2040L1200CU I3040L1200CU I4040L1200CU I4242L1225CU Spaces 12 16 30 8 12 16 20 30 40 42 Dimensions Height Width 10.80 9.80 12.80 9.80 20.80 9.80 10.80 9.80 10.80 9.80 14.80 9.80 12.80 9.80 14.80 9.80 24.80 9.80 26.80 9.80 Circuits 24 24 40 16 24 32 40 40 40 42 List Price $ 132.00 154.00 198.00 165.00 188.00 202.00 231.00 343.00 376.00 496.00 I0204ML1125 Rock Solid W W H Rock Solid 1ø: High Circuit Main Lug Interiors (no neutrals)햵 Amps 125 125 125 125 200 200 200 200 200 225 Catalog Number햳 IR1224L1125 IR1632L1125 IR2040L1125CU IR3040L1125 IR0816L1200TR햴 IR2040L1200CU IR2440L1200 IR3040L1200CU IR4040L1200CU IR4242L1225CU Spaces 12 16 20 30 8 20 24 30 40 42 Dimensions Height Width 10.80 7.40 12.80 7.40 14.80 7.40 20.80 7.40 10.80 7.40 14.80 7.40 16.80 7.40 20.80 7.40 24.80 7.40 26.80 7.40 Circuits 24 32 40 40 16 40 40 40 40 42 List Price $ 99.00 122.00 144.00 166.00 132.00 188.00 210.00 231.00 298.00 385.00 I1220L1200CT W Catalog Number햳 CTI2040L1200CU CTI2440L1200CU CTI3040L1200CU 3-PHASE H I0816ML1125CU Ultimate 1ø: Parallel Lug Interiors with Neutral Bars Amps 200 200 200 H Spaces 20 24 30 Circuits 40 40 40 Dimensions Height Width 14.80 9.80 16.80 9.80 20.80 9.80 List Price $ 418.00 441.00 496.00 Spaces 12 12 18 24 30 42 Circuits 24 24 36 42 42 42 Dimensions Height Width 10.50 8.70 10.50 8.70 13.50 8.70 16.50 8.70 19.50 8.70 25.50 8.70 List Price $ 254.00 276.00 330.00 385.00 518.00 606.00 W W H 3ø: Main Lug Interiors Amps 125 200 200 200 200 225 Catalog Number햳 I1224L3125CU I1224L3200CU I1836L3200CU I2442L3200CU I3042L3200CU I4242L3225CU H Parallel Lug I0408ML1125 Lug Data W Interior I0204ML1060 I0303ML3100 I1224ML1100 I0408ML1125 I0816ML1125CU/CUSP Ultimate Ultimate Rock Solid Rock Solid Three Phase Three Phase 햲 햳 Amperage 60 100 100 125 60 125 200/225 125 200/225 125 200/225 Wire range 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 300 kcmil - 4 2/0 - 4 AWG 300 kcmil - 4 300 kcmil - 6 300 kcmil - 6 UL Recognized Components. The letters “CU” in any catalog number represent copper bus bars. 1-16 햴 햵 AWG AWG AWG AWG Torque 45 lb. - ins. 45 lb. - ins. 45 lb. - ins. 45 lb. - ins. 45 lb. - ins. 110 lb. - ins. 110 lb. - ins. 110 lb. - ins. 275 lb. - ins. 340 lb. - ins. 340 lb. - ins. W H H I0202L1200 Ultimate Feed thru lugs provided. Convertible to main breaker using the MBK main breaker kits. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Ultimate Load Centers Main Breaker Wiring Diagrams Wiring Diagrams 2 29 30 G1630B1150 G1624B1100 G1624B1100CU W1624B1100CU LINE LINE N G 2 39 40 EQPT GND 1 G2440B1200 G2440B1200CU G2424B1100CU LINE BOND WHEN REQUIRED N G 30 29 G3030B1100CU 40 G3040B1200 G3040B1200CU W3040B1200CU 2 EQPT GND 39 1 EQPT GND 2 EQPT GND 1 EQPT GND EQPT GND G G NEUTRAL NEUTRAL NEUTRAL 2 EQPT GND 1 N G N G BOND WHEN REQUIRED NEUTRAL LINE BOND WHEN REQUIRED NEUTRAL LINE NEUTRAL G2020B1100 G2020B1100CU W2020B1100CU NEUTRAL 24 NEUTRAL 23 G EQPT GND 2 EQPT GND 20 19 1 EQPT GND EQPT GND G NEUTRAL NEUTRAL NEUTRAL EQPT GND G 2 BOND WHEN REQUIRED N N 1 BOND WHEN REQUIRED BOND WHEN REQUIRED NEUTRAL LINE NEUTRAL 1 EQPT GND 24 23 G1224B1100 G1224B1100CU W1224B1100CU G NEUTRAL 2 BOND WHEN REQUIRED N EQPT GND 24 1 EQPT GND 23 G EQPT GND 2 NEUTRAL NEUTRAL 1 EQPT GND EQPT GND G NEUTRAL N LINE BOND WHEN REQUIRED N NEUTRAL LINE 40 39 G4040B1200 G4040B1200CU W4040B 1200CU Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-17 LOAD CENTERS & CIRCUIT BREAKERS BOND WHEN REQUIRED LINE 1 All load centers comply fully with NEC and UL requirements for Class CTL. Single Main – 1-Phase, 3-Wire Ultimate Load Centers Wiring Diagrams All load centers comply fully with NEC and UL requirements for Class CTL. Single Main – 1-Phase, 3-Wire G1212L1125 G1212L1125CU 2 23 G 24 1 2 23 24 G1224L1125 G1224L1125CU W1224L1125CU G1224L1200CU W1224L1200CU G1624L1125 G1624L1125CU W1624L1125CU LINE LINE A N B NEUTRAL N NEUTRAL NEUTRAL 1 LINE A EQPT GND 12 B EQPT GND 11 G EQPT GND 2 BOND WHEN REQUIRED EQPT GND A N 1 EQPT GND G B EQPT GND NEUTRAL A LINE NEUTRAL BOND WHEN REQUIRED LINE NEUTRAL LOAD CENTERS & CIRCUIT BREAKERS A N B B N 39 40 G2440L1200 G2440L1200CU W2440L1200CU G2424L1125 G2020L1125 G202061125CU NEUTRAL 2 EQPT GND NEUTRAL 24 23 1 EQPT GND G EQPT GND 20 2 NEUTRAL 19 G 1 EQPT GND 2 EQPT GND 1 NEUTRAL NEUTRAL N EQPT GND G B NEUTRAL LINE A LINE 30 29 G3030L1200 G3030L1200CU 1-18 39 40 G3040L1200 G3040L1200CU W3040L1200CU Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2 39 40 EQPT GND 2 EQPT GND 1 NEUTRAL NEUTRAL G 1 EQPT GND N EQPT GND 2 EQPT GND 1 B G EQPT GND G B NEUTRAL A A N N B NEUTRAL LINE LINE NEUTRAL A NEUTRAL 1 Main Lug Wiring Diagrams G4040L1200 G4040L1200CU W4040L1200CU EQ Load Centers 3-Phase Load Center Wiring Diagrams N G N G N LOAD CENTERS & CIRCUIT BREAKERS G3030B3100CU G3042B3150CU G3042B3200CU W3042B3150CU W3042B3200CU G4242B3200CU G4242B3225CU W4242B3200CU W4242B3225CU N A B C G MAIN BREAKER POSITION WHEN REQ'D 4 MAIN BREAKER POSITION WHEN REQ'D 18 16 14 12 10 MAIN BREAKER POSITION WHEN REQ'D 30 28 26 24 22 20 N G A B C 8 6 N G A B C 2 G MAIN BREAKER POSITION WHEN REQ'D N A B C MAIN BREAKER POSITION WHEN REQ'D N G A B C Main Lug Wiring Diagrams G1224L3125CU G1224L3200CU W1224L3125CU W1224L3200CU 1 A B C A B C Main Breaker Wiring Diagrams G2442L3150CU G2442L3200CU W2442L3150CU W2442L3200CU G1836L3150CU W1836L3150CU G3042L3200CU W3042L3200CU G4242L3200CU G4242L3225CU W4242L3200CU W4242L3225CU Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-19 ® EQ Load Centers LOAD CENTERS & CIRCUIT BREAKERS 1 Main Breaker 300-400 Amperes Wiring Diagrams Main Breaker 300-400 Amperes Wiring Diagrams E3030MB1400SCU W3030MB1400CU 30-Poles Max. E4242MB1300SCU E4242MB1300FCU E4242MB1400SCU E4242MB1400FCU W4242MB1400CU 42-Poles Max. E3030MB3400SCU 30-Poles Max. E4242MB3300SCU E4242MB3400SCU E4242MB3400FCU W4242MB3400CU 42-Poles Max. Main Lugs 400 Ampere Wiring Diagrams W0606ML1400CU (6) 2-Poles Max. 1-20 E3030ML1400SCU W3030ML1400CO 30-Poles Max. E4242ML1400SCU E4242ML1400FCU W4242ML1400CU 42-Poles Max. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog E3030ML3400SCU 30-Poles Max. E4242ML3400SCU E4242ML3400FCU E4242ML3400CU 42-Poles Max. Ultimate Load Center Indoor and Outdoor Enclosures Knockout Diagrams Indoor Main Breaker and Main Lug Enclosures 1 4 K.O.s For 0.25" Conduit LOAD CENTERS & CIRCUIT BREAKERS 2 K.O.s For .038", 0.5", 0.75", 1", 1.25" Conduit 10 K.O.s For 0.5", 0.75", 1" Conduit 10 K.O.s For 1", 1.25", 2", 2.5" Conduit 52 K.O.s For 0.5" Conduit 12 K.O.s For .038", 0.5", 0.75" Conduit Outdoor Main Breaker and Main Lug Enclosures HS Hub Provision 2 K.O.s For 1", .75", .5" Conduit 2 K.O.s For 1.5", 1.25", 1" Conduit 3 K.O.s For 2.5", 2", 1.5", 1.25", 1" Conduit 15 K.O.s For .5" Conduit 2 K.O.s For 1", .75", .5" Conduit 4 K.O.s For .75", .5" Conduit Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-21 ® EQ Load Centers Outdoor Enclosures Knockout Diagrams LOAD CENTERS & CIRCUIT BREAKERS 1 Outdoor Enclosure Knockout Diagrams W0204ML1060 W0204ML1125 W0303ML3100 WB3100 WB2225 and WB32225 W0408ML1125 W0612ML1125 W0816ML1125 100A – 225A Main Breaker and Main Lug Devices W0406ML1125CU 1-22 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ® EQ Load Centers Indoor Enclosures Knockout Diagrams Indoor Enclosure Knockout Diagrams 1 LOAD CENTERS & CIRCUIT BREAKERS E0204ML1060 E0612ML1125 E0816ML1125 E1224ML1100F E0408ML1125 300-400A Main Breaker and Main Lug Devices E0303ML3100SCU EB3100 EB3225 All Riser Panels RAG24 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-23 Circuit Breakers Type QP with INSTA-WIRE Selection LOAD CENTERS & CIRCUIT BREAKERS 1 1-Pole Plug-In (120V AC) Continuous Current Rating @ 40° C 10 15 20 25 30 35 40 45 50 60 70 Type QP Type QPH 10,000A IR 22,000A IR Catalog Number Q110 NEW Q115 Q120 Q125 Q130 Q135■ Q140 Q145■ Q150 Q160 Q170 List Price $ 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 69.00 Catalog Number — Q115H Q120H Q125H■ Q130H Q135H■ Q140H Q145H■ Q150H Q160H■ Q170H■ Type HQP 65,000A IR List Price $ — 66.00 66.00 66.00 72.00 72.00 72.00 72.00 72.00 72.00 93.00 Catalog Number — Q115HH■ Q120HH■ Q125HH■ Q130HH■ Q135HH■ Q140HH■ Q145HH■ Q150HH■ Q160HH■ Q170HH■ List Price $ — 123.00 123.00 123.00 143.00 143.00 143.00 143.00 143.00 143.00 179.00 2-Pole Plug-In (Common-Trip 120/240V AC ) 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 Q210 Q215 Q220 Q225 Q230 Q235 Q240 Q245 Q250 Q260 Q270 Q280 Q290 Q2100 Q2110 Q2125 71.00 71.00 71.00 71.00 71.00 71.00 71.00 71.00 71.00 71.00 145.00 210.00 210.00 210.00 433.00 433.00 — Q215H Q220H Q225H■ Q230H Q235H■ Q240H Q245H■ Q250H Q260H Q270H Q280H■ Q290H Q2100H Q2110H Q2125H — 147.00 147.00 147.00 147.00 147.00 147.00 147.00 147.00 147.00 236.00 330.00 330.00 330.00 1128.00 1128.00 — Q215HH Q220HH Q225HH■ Q230HH Q235HH■ Q240HH■ Q245HH■ Q250HH Q260HH Q270HH Q280HH■ Q290HH■ Q2100HH Q2110HH■ Q2125HH — 313.00 313.00 313.00 313.00 313.00 334.00 334.00 334.00 334.00 558.00 689.00 689.00 689.00 2277.00 2277.00 2-Pole Plug-In (Common-Trip 240V AC) 15 20 30 40 50 60 70 100 Q215R Q220R Q230R Q240R Q250R Q260R Q270R Q2100R■ 213.00 213.00 213.00 213.00 213.00 213.00 236.00 330.00 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3-Pole Plug-In (Common-Trip 240V AC) 10 15 20 25 30 35 40 45 50 60 70 80 90 100 Q310 Q315 Q320 Q325 Q330 Q335 Q340 Q345 Q350 Q360 Q370 Q380 Q390 Q3100 253.00 253.00 253.00 253.00 253.00 253.00 253.00 253.00 253.00 253.00 317.00 380.00 380.00 380.00 — Q315H Q320H Q325H■ Q330H Q335H■ Q340H Q345H■ Q350H Q360H Q370H Q380H Q390H Q3100H — 395.00 395.00 395.00 395.00 395.00 395.00 395.00 395.00 500.00 500.00 560.00 560.00 560.00 — Q315HH■ Q320HH Q325HH■ Q330HH Q335HH■ Q340HH Q345HH■ Q350HH Q360HH Q370HH■ Q380HH■ Q390HH■ Q3100HH QP / QPH / HQP Internal Accessories Control Voltage AC 120V Shunt Trip 24V Shunt Trip 120V Auxiliary Switch 3-Pole Padlocking Device Handle Block Catalog Number add suffix …00S01■ add suffix …00S07■ add suffix …01■ ECQLD3 ECHBD1 ■ Built to order. Allow 2-3 weeks for delivery. UL Listed for use with 60/75˚ wire through 125 amps, HACR rated. 1A and 1B contacts. UL Listed for frequent switching applications (SWD). 1-24 Field/Factory Installed Factory Factory Factory Field Field — 527.00 527.00 527.00 527.00 527.00 615.00 615.00 615.00 660.00 660.00 740.00 740.00 740.00 Modifications List Price $ 134.00 (adder) 134.00 (adder) 74.00 (adder) 98.00 9.10 Description 400 Hz Calibration 415V 50Hz Calibration Marine 50˚C Ambient Calibration Fungus Proofing 120V AC Fluorescent Lighting. Listed for use on 3-phase grounded “B” systems — 10,000 for this application. Shipped 12 per sleeve. Shipped 6 per sleeve. Shipped 4 per sleeve. UL Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog Number add suffix …Y add suffix …E List Price $ 7.50 (adder) No adder add suffix …M No adder add suffix …F 10.00 (adder per pole) UL Listed 5 KA IR. UL Listed. & 2-Poles only. NEW Type QP1, UL listed for 16 AWG conductors and multiple wires. Not 1 Discount Schedule RESI Circuit Breakers Duplex, Triplex and Quadplex Plug-In Breakers Selection Duplex Circuit Breakers Catalog Number List Price $ Catalog Number QT 15 –15 15 – 20 20 – 20 20 – 30 15– 30 ■ 20– 30 30 – 30 Q1515 Q1520 Q2020 Q2030 Q3015 Q3020 Q3030 69.00 69.00 69.00 69.00 69.00 69.00 69.00 Q1515NC햲 Q1520NC햲 Q2020NC햲 — — — Q3030NC햲 1-Pole 10K AIC 120V AC List Price $ 114.00 114.00 114.00 — — — 114.00 QT Duplex SHIPPING: 12 per carton, (Wt. 4.8 lbs.) These space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated. Triplex Circuit Breakers Breaker Type QT 2-Pole 10K AIC 120/240V AC Center Common Trip Ampere Rating Single Pole Common-Trip 2-Pole Catalog Number 15 15 Q21515CT 15 20 Q21520CT 15 25 Q21525CT■ 15 30 Q21530CT 15 35 Q21535CT■ 15 40 Q21540CT 15 45 Q21545CT■ 15 50 Q21550CT 20 20 Q22020CT 20 25 Q22025CT■ 20 30 Q22030CT 20 35 Q22035CT■ 20 40 Q22040CT 20 45 Q22045CT■ 20 50 Q22050CT 30 30 Q23030CT SHIPPING: 6 per carton, (Wt. 4.9 lbs.) LOAD CENTERS & CIRCUIT BREAKERS Ampere Rating 1 Breaker Type List Price $ 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 134.00 128.00 QT Triplex These space saver triplex breakers provide a 2-pole common trip breaker for 120/240V AC circuits and two single poles for 120V AC circuits. Triplex require two panel spaces. HACR rated. Quadplex Circuit Breakers Breaker Type QT 2-Pole 10K AIC 120/240V AC Common Trip Ampere Rating Inside Outside 2-Pole 2-Pole 15 20 20 20 30 30 40 50 SHIPPING: 6 per Catalog Number 15 Q21515CT2 20 Q22020CT2 30 Q23020CT2 40 Q24020CT2 30 Q23030CT2 40 Q24030CT2 40 Q24040CT2 30 Q23050CT2 carton, (Wt. 4.8 lbs.) List Price $ 139.00 139.00 139.00 139.00 139.00 139.00 139.00 139.00 QT Accessories Description Catalog Number Handle Block ECBX231M For inches / millimeters conversion, see Application Data section. Discount Schedule RESI QT Quadplex Common Trip These space saver quadplex breakers provide two sets of common trip, two-pole breakers for 120/240V AC circuits, and require two panel spaces. HACR rated. List Price $ 9.70 ■ Built to order. Allow 2–3 weeks for delivery. 햲 Non-CTL. For replacement use only in panels manufactured before 1968 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-25 Circuit Breakers LOAD CENTERS & CIRCUIT BREAKERS 1 Arc-Fault and Ground-Fault Breakers Selection/Wiring Diagrams ▪ UL Listed and CSA Certified ▪ HACR Rated ▪ Standard 1 inch per pole format with plug-in design Ground-Fault Circuit Interrupters (Class A - 5mA)햳 Ground-fault circuit interrupters (GFCI) provide Class A ground fault protection. A GFCI is a device intended for personnel protection and will de-energize the circuit when a fault current to ground is 6 milliamperes or more. 10,000 A IR Breaker Type QPF/QPHF 1-Pole 120V AC Plug-In QPF/QPHF 2-Pole 120/240V AC Plug-In 22,000 A IR Ampere Rating Catalog Number List Price $ Catalog Number List Price $ 15 20 25 30 QF115 햲 QF120 햲 QF125 ■ QF130 255.00 255.00 255.00 255.00 QF115H햲 QF120H햲■ — QF130H 515.00 515.00 — 515.00 15 20 30 40 50 60 QF215 QF220 QF230 QF240 QF250 QF260 454.00 454.00 454.00 454.00 454.00 454.00 QF215H QF220H QF230H QF240H QF250H QF260H 678.00 678.00 678.00 678.00 678.00 678.00 1-Pole GFCI 2-Pole GFCI 1-Pole Equipment Protection 2-Pole Equipment Protection 1-Pole AFCI 2-Pole AFCI Ground Fault Equipment Protection (30mA)햳 Type EQF circuit breakers provide protection of equipment from damaging line-to-ground fault currents by de-energizing the circuit for all ungrounded conductors of the faulted circuit. QE/QEH 1-Pole 120V AC Plug-In QE/QEH 2-Pole 120/240V AC Plug-In 15 20 30 QE115 햲 QE120 햲 QE130 465.00 465.00 465.00 QE115H햲 QE120H햲 QE130H 777.00 777.00 777.00 15 20 30 40 50 60 QE215 QE220 QE230 QE240 QE250 QE260 ■ 616.00 616.00 616.00 616.00 616.00 616.00 QE215H QE220H QE230H QE240H QE250H QE260H■ 1016.00 1016.00 1016.00 1016.00 1016.00 1016.00 Arc-Fault Circuit Interrupters (AFCI)햳 Arc-fault circuit interrupters (AFCI) detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. An AFCI is a branch feeder device intended to mitigate the effects of arc-faults by de-energizing the circuit when an arc-fault is detected. QAF/QAFH 15 Q115AF햲 255.00 Q115AFH■햲 515.00 1-Pole 120V AC 20 Q120AF햲 255.00 Q120AFH■햲 515.00 QAF/QAFH 15 Q215AF 454.00 Q215AFH■ 660.00 20 Q220AF 454.00 Q220AFH■ 660.00 2-Pole 120/240V AC Wiring Diagrams QAF/QPF/QE Accessories Description Catalog Number Handle Block ECBX231M ■ Built to order. Allow 2–3 weeks for delivery. 햲 UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. 1-26 List Price $ 9.70 햳 White line neutral (pigtail) must be connected to the panel neutral for the device to function. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Circuit Breakers Special Application Breakers Selection HID Lighting 1 For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. LOAD CENTERS & CIRCUIT BREAKERS Complete Breaker UL Unenclosed Breaker Type QP 1-Pole 120V AC Wiring Diagram Ampere Rating Catalog Number List Price $ Figure 1 15 20 30 Q115HID 햲 ■ Q120HID 햲 Q130HID 44.50 44.50 44.50 Figure 2 15 20 30 Q215HID Q220HID ■ Q230HID ■ 91.00 91.00 91.00 QP 2-Pole 120/240V AC Switching Neutral Molded Case Switch For applications that do not require overcurrent protection. QP 2-Pole Plug-In 240V AC Figure 2 30 60 Q230S Q260S 49.00 49.00 No-Noise For applications that require a reduction in the 60-cycle hum of a standard breaker. QP 2-Pole 120/240V AC Figure 2 50 60 70 90 Q250NN■ Q260NN Q270NN Q290NN■ 72.00 72.00 148.00 203.00 Water Heater Switching Neutrals Figure 1 Figure 2 Figure 3 Figure 4 Used where all conductors are required to be disconnected. Neutral pole of the circuit breaker does not connect to loadcenter bus. One side is wired to neutral and the other side to the device. QG 2-Wire Common Trip 120V AC Figure 3 15 20 30 QG215 QG220 QG230■ 119.00 119.00 119.00 Figure 4 15 20 30 QG315■ QG320 QG330■ 172.00 172.00 172.00 QG 3-Wire Common Trip 120/240V AC Tungsten Lighting For high wattage, tungsten-lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. QP 1-Pole 120V AC Figure 1 15 20 Q115T 햲 ■ Q120T 햲 Figure 5 32.00 33.00 Water Heater Wiring Diagrams When installed in a loadcenter, the water heater circuit breaker does not make electrical connection with the loadcenter bussing. Separate metered circuit is connected to line terminals of the breaker. Used in special rate water heating areas. QW 2-Pole 120/40V AC Plug-In Figure 5 15 20 30 ■ Built to order. Allow 2–3 weeks for delivery. QW215 QW220 QW230 91.00 91.00 91.00 햲 UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. Note: All circuit breakers on this page are 10K AIC Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-27 Circuit Breakers 3/4 Inch Plug-In Breakers Selection LOAD CENTERS & CIRCUIT BREAKERS 1 Features ▪ 3/4" format ▪ HACR Rated ▪ UL Classified for use in certain Square D load centers Type QD Circuit Breakers The Type QD circuit breaker line is available in 1-pole and 2-pole common trip versions listed on this page. The circuit breakers are UL Classified and UL Listed. All QD breakers are supplied with load side connectors suitable for 60/75°C wire and are calibrated for 40°C maximum ambient applications. UL Classified Siemens Type QD circuit breakers are UL Classified for use in specific Square D load centers in place of Square D Type QO® circuit breakers. A Panelboard Compatibility List packaged with each QD breaker shows which type QD circuit breakers are acceptable for use in Square D load centers. The interrupting rating on these circuit breakers is 10,000A IR maximum and they are not series rated with Square D circuit breakers or equipment. This UL Classification allows a Siemens Type QD circuit breaker to be used in place of a Square D Type QO circuit breaker in those load centers that are specifically shown on the Panelboard Compatibility list. For additional information, contact your local Siemens sales engineer. For inches / millimeters conversion, see Application Data section. 1-28 1-Pole 2-Pole 120V 120/240V Common Trip Continuous Current Rating @ 40°C Catalog Number List Price $ Catalog Number List Price $ 15 20 30 40 50 60 D115 햲 D120 햲 D130 D140 D150 D160 33.00 33.00 33.00 33.00 33.00 33.00 D215 D220 D230 D240 D250 D260 72.00 72.00 72.00 72.00 72.00 72.00 Shipping Weights Number of Poles Number Per Carton Shipping Weight (lbs.) 1 2 16 8 3.8 4.2 Panelboard Compatibility List Listed Panelboards — Square D — Catalog Numbers QO2L30F/S QO2-4L70F/S QO2-4L70TS QO2-4L70RB QO6-12L100F/S QO6-12L100DF/S QO6-12L100TF/S QO6-12L100DTF/S QO6-12L100RB QO8-16L100F/S QO8-16L100DF/S QO8-16L100TF/S QO-16L100DTF/S QO8-16L100RB QO112M100/RB QO116M100/RB QO120M100/RB QO124M100 QO12L100DF/S QO12L100RB QO12-20M100/RB QO12-20M100TF/S 햲 QO12M100/RB QO16-20M100/RB QO16M100/RB QO20M100/RB QO112L125G/RB QO112-24L125/RB QO112-24L125GWGC QO116L125G QO116-24L125G/RB QO12-24L125/RB QO120-24L125G QO120-24L125GWGC QO120L125G QO124L125G/RB QO124M125/RB QO16L125/RB QO16-12M125FTRB QO16-24L125/RB QO20L125/RB QO20-24L125/RB QO24L125/RB QO120-30L150G QO120-30M150/RB QO124L150G QO124M150 QO130L150G/RB QO130M150/RB QO16L150/RB QO16M150/RB QO16-30L150/RB QO18-16M150FTRB QO20-30M150/RB QO20-30M150TF/S QO20-30L150 QO24L150/RB QO24M150/RB QO30L150/RB QO30M150/RB QO8-16M200FT/RB QO112L200G/RB QO120-40M200/RB QO120-40M200TC QO124M200 QO130L200G/RB QO130-40M200 QO130200/RB QO130-40L200G/RB QO140M200/RB QO16L200/RB QO16M200/RB QO18-16M200FTRB QO20-40L200/RB QO20-40M200TF/S QO20-40M200/RB QO24L200/RB QO24M200/RB QO30L200/RB QO30M200/RB QO30-40L200/RB QO30-40M200/RB QO40M200/RB QO140M225 QO142L225G/RB UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. One or two load conductors. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Circuit Breakers Main and Branch Circuit Breakers Catalog Number QN 150 175 200 QN2150 QN2175■ QN2200 477.00 477.00 477.00 QN2150R QN2175R ■ QN2200R 477.00 477.00 477.00 10 10 10 150 175 200 QN2150H QN2175H ■ QN2200H 586.00 586.00 586.00 QN2150RH QN2175RH ■ QN2200RH 586.00 586.00 586.00 22 22 22 150 175 200 HQN2150 HQN2175 ■ HQN2200 2514.00 2514.00 2514.00 HQN2150R HQN2175R ■ HQN2200R 2514.00 2514.00 2514.00 65 65 65 QNH 2-Pole 120/240V AC HQN 2-Pole 120/240V AC Catalog Number List Price $ UL Interrupting Ratings (kA) QNR QN Requires 4 panel spaces, 2 adjacent and 2 opposite. SHIPPING: 1 per carton (Wt. 3 lbs.) Main Breaker Kits For use in Ultimate Load Centers UL Ampere Catalog List Type Rating Number Price $ For use in EQIII Load Centers UL Ampere Catalog Type Rating Number EQ8681 EQ8682 EQ8693 EQ8695 EQ8696 EQ9675 EQ9676 EQ9683 EQ9685 EQ9686 100 125 150 200 225 MBK100A MBK125A MBK150A MBK200A MBK225A 230.00 473.00 588.00 588.00 588.00 100 125 150 200 225 MBK100 MBK125 MBK150 MBK200 MBK225 List Price $ UL Interrupting Ratings (kA) 260.00 513.00 639.00 639.00 639.00 22 22 22 22 22 EQ96XX Breaker Type QPJ 3-Pole 240V AC Ampere Rating Catalog Number UL Interrupting Ratings (kA) List Price $ 125 150 200 QPJ3125 QPJ3150 QPJ3200 10 10 10 1226.00 1226.00 1226.00 Requires 6 spaces due to cross over design. Fits only EQIII 125-400A 3-phase load centers SHIPPING: 5 per carton (Wt. 17 lbs.) Breaker Type QPP 2-Pole 120/240V AC QPPH 2-Pole 120/240V AC HQPP 2-Pole 120/240V AC HQPPH 2-Pole 120/240V AC Ampere Rating Catalog Number 125 150 175 200 225 Q2125B Q2150B Q2175B■ Q2200B Q2225B 125 150 175 200 225 UL Interrupting Ratings (kA) Volts AC 120/240 List Price $ 441.00 441.00 441.00 441.00 441.00 10 10 10 10 10 Q2125BH Q2150BH Q2175BH■ Q2200BH Q2225BH■ 1129.00 1129.00 1129.00 1129.00 1129.00 22 22 22 22 22 125 150 175 200 225 Q2125BHH■ Q2150BHH Q2175BHH■ Q2200BHH Q2225BHH■ 2238.00 2238.00 2238.00 2238.00 2238.00 65 65 65 65 65 100 125 150 175 200 225 HQ2100BH■ HQ2125BH■ HQ2150BH■ HQ2175BH■ HQ2200BH■ HQ2225BH■ 2733.00 2733.00 2733.00 2733.00 2733.00 2733.00 100 100 100 100 100 100 MBK (100,125)A MBK (150,200,225)A 2-Pole QPP Circuit breaker is 4-poles wide. For use on 200A modular and Uni-Pak® metering, and on 300-600A load centers. SHIPPING: 8 per master carton (Wt. 17.5 lbs., 2 per carton) QPJ QN/QNH/HQN and Ultimate Main Breaker Kit Accessories (Factory installed only) Shunt Trip Control Voltage AC Add Suffix List Adder $ 120V 00S01 ■ 275.00 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. Discount Schedule RESI All circuit breakers on this page are common trip. Reverse handle. Not UL Listed. MBK100A for use in 100 and 125A load centers. QNR required for horizontal applications or vertical applications where the lugs are facing up. The QN breaker is required for vertical applications where the lugs are facing down as shown. MBK125A for use in 125A load centers. MBK150A for use in 150, 200 and 225A load centers. MBK200A for use in 200 and 225A load centers. MBK225A for use in 225A load centers. MBK175A for use in 200 and 225A load centers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-29 LOAD CENTERS & CIRCUIT BREAKERS Ampere Rating 1 Breaker Type 2-Pole 120/240V AC List Price $ Selection Circuit Breakers Line Diagrams LOAD CENTERS & CIRCUIT BREAKERS 1 Dimension Drawings 1-Pole 2-Pole 3-Pole 3" 23/8" 31/8" Type QT Type QPF, QPHF, QE, QAF, QAFH Type EQ8681, EQ8682 Type EQ8693, EQ8695, EQ8696 Type QPJ Type QN, QNH, HQN Type QNR, QNRH, HQNR Type QPP, QPPH, HQPP, HQPPH QP, QPH, HQP 햲 All standard circuit breakers are calibrated to 40°C maximum ambient application. 1-30 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Circuit Breakers Lug Data Cables Per Connector Connector Wire Range 2 1 1 1 1 #16 AWG Cu #14–#8 AWG Cu #12–#8 AWG Al #14–#6 AWG Cu #14–#6 AWG Al 40–50 1 1 #8–#6 AWG Cu #8–#4 AWG Al 55–70 1 1 #8–#4 AWG Cu #8–#2 AWG Al 80–100 1 1 #4–#1/0 AWG Cu #2–#1/0 AWG Al 110–125 햳 1 1 #2–#1/0 AWG Cu #1/0–#2/0 AWG Al LOAD CENTERS & CIRCUIT BREAKERS Circuit Breaker Ampere Rating 1 Circuit Breaker Type Reference LOAD SIDE QP, QPH, HQP, Plug-in 10 15–20 25–35 QT 1 #14–#8 AWG Cu 1 #12–#8 AWG Al 15–20 1 1 1 1 1 1 1 1 1 2 15–20 1 25–35 1 1 1 1 #8 AWG CU-Al #8–#6 AWG Cu #8–#4 AWG Al #14–#10 AWG Cu #12–#8 AWG Al #8–#6 AWG Cu #8–#4 AWG Al #14–#12 AWG Cu #12–#10 AWG Al #14–#8 AWG Cu Only #14–#12 AWG Cu #12–#10 AWG Al #10–#8 AWG Cu #10–#6 AWG Al #8–#6 AWG Cu #8–#4 AWG Al 150–200 1 #1–300kcmil Cu-Al 100 1 #4–3/0 AWG Cu-Al 125 1 #4–3/0 AWG Cu-Al 150 1 #1–300kcmil Cu-Al 200 1 #1–300kcmil Cu-Al 225 1 #1–300kcmil Cu-Al 125 1 1 1 1 1 1 1 1 1 1 #1 AWG Cu #2/0 AWG Al #1/0 AWG Cu #3/0 AWG Al #2/0 AWG Cu #4/0 AWG Al #3/0 AWG Cu 250kcmil AWG Al #4/0 AWG Cu 300kcmil AWG Al 15–35 40 40–50 QPF, QPHF 15–30 40–60 QAF, QAFH QD 15–20 40–60 QN, QNH, HQN EQ8681-Ultimate EQ8682-Ultimate EQ8693-Ultimate EQ8695-Ultimate EQ8696-Ultimate QPP, QPPH, HQPP, HQPPH 150 175 200 225 EQ9675-EQIII 100 1 1 #3 AWG Cu #1 AWG Al EQ9677-EQIII 125 1 1 #1 AWG Cu #2/0 AWG Al EQ9683-EQIII 150 1 1 #1/0 AWG Cu #3/0 AWG Al EQ9685-EQIII 200 1 1 #3/0 AWG Cu 250kcmil AWG Al EQ9686-EQIII 225 1 1 #4/0 AWG Cu 300kcmil AWG Al QPJ 125–200 1 #2–300kcmil Cu-Al Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-31 Surge Protection LOAD CENTERS & CIRCUIT BREAKERS 1 Point-of-Entry Selection Circuit Breaker and Secondary Surge Arrester Circuit Breaker and TVSS Features ▪ UL Listed ▪ Easy to install ▪ Perfect for retrofit - replaces two 1-inch breakers without losing any circuits ▪ A single device protects the entire electrical system from damage caused by surges By installing a Siemens Circuit Breaker/Surge Arrester or Circuit Breaker/TVSS device in the load center of the residence, surge protection is provided for all branch circuits.햴 Two red LED indicator lights are provided to show that surge protection is provided for all circuits connected to the panelboard. As a Siemens exclusive feature, the device notifies the owner of loss of surge protection by tripping one or both of the circuit breakers. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided. Breaker Type Ampere Rating Catalog Number List Price $ Surge Type QP햲햳 (2) 15 QSA1515 261.00 Surge Arrester (2) 20 QSA2020 261.00 Surge Arrester 1-Pole 120/240V AC Surge Arrester 10K AIC The Siemens circuit breaker and transient voltage surge suppressor is comprised of a highly effective TVSS module integrated with (2) 1-pole circuit breakers. This device incorporates the robust features of our secondary circuit breaker surge arrester with a lower clamping voltage rating. By installing a Siemens Circuit Breaker/TVSS device in the load center of the residence, surge protection is not only provided for all branch circuits, but also, fixtures, appliances, motors, and other electronic equipment in the house served by that load center.햴 QP햲햳 1-Pole 120/240V AC 10K AIC (2) 20 QSA2020TVSS Number of Poles Initial Clamping Level Transient Energy Rating Secondary Surge Arrester Voltage Rating Transient Suppression Voltage Rating Peak Current Rating (impulse) Discharge Voltage Characteristic (line-to-neutral) Discharge Current Withstand Rating (line-to-neutral) Circuit Breaker Interrupting Rating Warranty Amount Connected Appliances Warranty햴 Warranty Period Lightning Protection 햲 햳 UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. HACR Rated 1-32 377.00 TVSS Circuit Breaker and Secondary Surge Arrester (2) 1-Pole Circuit Breakers 360 Volts 460 Joules line-to-neutral 920 Joules line-to-line 175V AC max. line-to-ground – – 40,000 amperes @ 1,500A, 600 volts @ 5,000A, 800 volts Circuit Breaker and Transient Voltage Surge Suppressor (2) 1-Pole Circuit Breakers 240 Volts 360 Joules line-to-neutral 720 Joules line-to-line – 500 volts peak, line-to-neutral 1000 volts peak, line-to-line 40,000 amperes @ 1,500A, 600 volts @ 5,000A, 800 volts 10,000 amperes 10,000A, 120/240V AC $10,000 No 24 months No 10,000 amperes 10,000A, 120/240V AC $20,000 Yes 24 months No 햴 See warranty for detailed coverage information. Does not include electronic devices. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Surge Protection Point-of-Entry Selection Transient Voltage Surge Suppressor 1 UL listed Rated for single phase panels up to 400 amps Audible Alarm Guaranteed lightning protection LOAD CENTERS & CIRCUIT BREAKERS ▪ ▪ ▪ ▪ TPSA9040 shields motor-driven appliances in residential and light commercial applications against electrical power surge damage, including lightning, from entering through the main electrical service panel. Two LED lights indicate protection status. The audible alarm alerts you when protection is disrupted. Surge Type TVSS Catalog Number TPSA9040햲 Single Pulse Energy Dissipation Spike Capacity Line Voltage Initial Clamping Level Rated Voltage Short Circuit Rating Warranty Amount Connected Appliances Warranty Warranty Period Lightning Protection TPSA9040 List Price $ 441.00 1080 Joules 40,000 amperes 102/2401 Phase 50/60Hz 400V 150V 10,000 amperes $20,000 Yes 3 years Yes Secondary Surge Arresters ▪ UL listed ▪ Rated for single and three phase panels ▪ Suitable for indoor and outdoor installation These Secondary Surge Arresters, also referred to as Lighting Arresters, are designed to protect electrical equipment from damaging effects of Spikes (+) and Notches (-) caused by lightning, utility switching, insulation arcing, electrical motor cycling, and other large or sudden changes in electrical power flow on incoming AC power lines. Phase 1 3 Catalog Number TPSASA1 TPSESA3 List Price $ 154.00 531.00 TPSEA3 1-Phase 3-Phase 햲 For flush mounting applications, use flush mount kit TPSA9040F. Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-33 Surge Protection Point-of-Entry or Point-of-Use Selection LOAD CENTERS & CIRCUIT BREAKERS 1 Telecommunication Protector ▪ ▪ ▪ ▪ UL listed Rated for RJ45 Modem/Fax/DSL protection Easy to install Guaranteed lightning protection TPSTEL protects telephone or modems connected electronics in residential and light commercial applications against electrical transient damage, including lightning, from entering through the main telephone connection. To have complete protection for your equipment, home, or business, it is important to protect AC power lines and all data lines the equipment is connected through. Surge Type Telco Catalog Number TPSTEL AC Surge Protection EMI/RFI Catastrophic Surge Circuit Spike Capacity Let Through Voltage Overcurrent Protection Response Time Data Line Protected 0.0 db Yes 200 Amps <260V Yes 1 ns 3, 4, 5, 6 - RJ45 Coaxial Protector ▪ ▪ ▪ ▪ TPSTEL List Price $ 245.00 TPSCOAX UL listed Rated for CATV, DSS, TV, VCR and cable modem Easy to install Guaranteed lightning protection TPSCOAX shields coaxial connected electronics in residential and light commercial applications against electrical transient damage, including lightning, from entering through the main cable connection. To have complete protection for your equipment, home, or business, it is important to protect AC power lines and all data lines the equipment is connected through. Surge Type Coaxial Catalog Number TPSCOAX AC Surge Protection Frequency Range Catastrophic Surge Circuit Spike Capacity Let Through Voltage Overcurrent Protection Response Time Insertion Loss 1-34 List Price $ 245.00 1 mHz thru 1.45 gHz Yes 200 Amps <85V Yes 1 ns 0db to 3.0 db Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Electricenter Accessories햸 Selection Circuit Breaker Accessories Load Center Conversion Kits List Pack Price $ Qty.햷 ECQTH2 Handle Tie - Duplex 4.40 25 ECQTH3 Handle Tie - 2-Pole 97.00 50 ECQL1 Handle Blocking Device - 1" Handles 9.10 25 ECBX231M Handle Blocking Device - 1/2" Handles 9.70 25 ECMBR2 Main Breaker Retainer - for Ultimate Load Centers 14.50 Catalog Number List Pack Price $ Qty.햷 Description MBK100A Main Breaker Conversion Kit - for use in 100–125A Ultimate Load Centers 230.00 1 MBK125A Main Breaker Conversion Kit - for use in 125A Ultimate Load Centers 473.00 1 MBK150A 1 Main Breaker Conversion Kit - for use in 150–225A Ultimate Load Centers 588.00 1 6.60 1 MBK200A Main Breaker Conversion Kit - for use in 200–225A Ultimate Load Centers 588.00 1 MBK225A Main Breaker Conversion Kit - for use in 225A Ultimate Load Centers 588.00 1 ECMLK125 Main Lug Conversion Kit - 100–125A Ultimate Load Centers 24.50 1 ECMLK225 Main Lug Conversion Kit - 150–225A Ultimate Load Centers 26.50 1 MCB12 300MCM Lugs and Straps for Old EQ Style Load Center 50.00 1 ECMBR1햲 Main Breaker Retainer - for EQ Load Centers ECQML12햸 Mechanical Interlock 299.00 10 ECPLD1 Padlocking Device - 1-Pole Type QP, QAF, QPF, QT Duplex 10.10 1 ECPLD2 Padlocking Device - 2-Pole Type QP, QAF, QPF, QT Triplex/Quadplex 10.20 1 ECPLD125햳 Padlocking Device - 100-125A Main Breaker 8.60 1 ECPLD2R NEW Red Padlock for 2-pole 1" breakers and quad breakers 15.30 1 ECQLN3 NEW Padlock for QN, QNR, and 150-225A MBKA 55.00 1 Lug Kits Ground Bar Kits Catalog Number Description ECGB5 Ground Bar Kit - 5 Position, #4-14 AWG Cu/Al 18.40 ECGB10 Ground Bar Kit - 10 Position, #4-14 AWG Cu/Al 21.00 Catalog Number ECLKB1햶 Description Ground Lug Kit - for Ultimate Load Centers 1 ECLK3 Neutral Lug Kit - #1-300 AWG Cu/Al 24.00 1 1 ECLK1-2 Neutral Lug Kit - #2-1/0 AWG Cu/Al 13.90 1 ECLK2 Neutral Lug Kit - #4-2/0 AWG Cu/Al 18.40 1 ECLK2SC Neutral Lug Kit for Swiss Cheese style neutral/ground bar - #4-2/0 AWG Cu/Al 21.00 1 ECLK2150 Sub-Feed Lug Kit - #14-2/0 AWG Cu, #1/0 AWG Al 100.00 1 ECLK2125 Sub-Feed Lug Kit - #3-1 AWG Cu, #1/0 AWG Al ECLK2225 Sub-Feed Lug Kit - #2-300 ECLK3125 3-Pole Sub-Feed Lug Kit - #3-1 AWG Cu, #1/0 AWG Al ECLK3225 3-Pole Sub-Feed Lug Kit - #2-300 AWG List Pack Price $ Qty.햷 ECGB101 Ground Bar Kit - 10 Position, #4-14 AWG Cu/Al, 1 Position #14-1/0 Cu/Al 27.00 1 ECGB14 Ground Bar Kit - 14 Position, #4-14 AWG Cu/Al 24.00 1 ECGB141 Ground Bar Kit - 14 Position, #4-14 AWG Cu/Al, 1 Position #14-1/0 Cu/Al 29.50 1 ECGB142 Ground Bar Kit - 14 Position, #4-14 AWG Cu/Al, 1 Position #6-2/0 Cu/Al 33.00 1 ECGB20 Ground Bar Kit - 20 Position, #4-14 AWG Cu/Al 27.00 1 ECGB201 Ground Bar Kit - 20 Position, #4-14 AWG Cu/Al, 1 Position #14-1/0 Cu/Al 33.00 1 ECGB202 Ground Bar Kit - 20 Position, #4-14 AWG Cu/Al, 1 Position #6-2/0 Cu/Al 33.00 1 ECINSGB5 Insulated Isolated Ground Bar - 5 Position 33.00 1 ECINSGB14 Insulated Isolated Ground Bar - 14 Position 42.50 1 ECINSGB20 Insulated Isolated Ground Bar - 20 Position 48.50 1 ECCS1 Collar Strap - #14-1/0 AWG Cu/Al 8.00 1 ECCS2 Collar Strap - #6 AWG - 250 kmil Cu/Al 23.00 1 Hubs Catalog Number List Pack Price $ Qty.햷 Description ECHS000 Closure Plate 38.00 1 ECHS075 Hub - 3/4" 39.50 1 ECHS100 Hub - 1" 39.50 1 ECHS125 Hub - 1 1/4" 39.50 1 ECHS150 Hub - 1 1/2" 39.50 1 ECHS200 Hub - 2" 69.00 1 ECHS250 햲 햳 햴 햵 Hub - 2 1/2" Not suitable for use on 15–50A, 10k AIC type QP circuit breakers. For use with Ultimate Load Center main breakers. 2 filler plates required for 150–225A main breaker opening. Provides 1/4" clearance between wall and load center. Discount Schedule RESI 109.00 햶 햷 1 List Pack Price $ Qty.햷 26.50 1 30.50 1 148.00 1 42.00 1 202.00 1 Miscellaneous Load Center Accessories Catalog Number List Pack Price $ Qty.햷 Description ECQFL2 Add-A-Lock - Flush Mount, 100–225A Ultimate Load Centers ECQFL1 Add-A-Lock - Flush Mount, Replacement Only ECCP1 Circuit Directory Cards - 42 Circuit ECQF3 햴 Filler Plate - Branch Breakers and 150–225A Ultimate Main Breaker (bag of 5) 14.20 5 QF3햴 Filler Plate - Branch Breakers and 150–225A Ultimate Main Breaker (carton of 100) 2.80 1 ECMBF125 Filler Plate - 100–125A Ultimate Main Breaker ECRLK250 Gutter Tap Kit - 250-1/0 Main, 250-6 Tap ECSMK1 햵 Spacer Kit ECTS2 Trim Screws (bag of 6 screws) ECDL1 Appliance Labels ECSN1 Extended screws and nuts for use on HC Hubs RAG24 Riser Auxilliary Gutter. For use on Siemens Load Centers 24" or larger For use with Ultimate Load Centers to convert left side neutral bar into a bounded ground bar, once tie-strap is removed. The pack quantity is the number of pieces received when one catalog number is ordered. Example: When one ECQF3 is ordered, a bag of 5 plates is shipped. 햸 89.00 1 89.00 1 616.00 100 16.20 1 255.00 3 25.00 4 9.80 6 6.60 10 10.60 4 362.00 1 For a complete list of standby power mechanical interlock kits, see the Standby Generator Section 17. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-35 LOAD CENTERS & CIRCUIT BREAKERS Description 1 Catalog Number Electricenter Accessories LOAD CENTERS & CIRCUIT BREAKERS 1 General QT Dual Tie Handle ECQTH2 QP 2-Pole Tie Handle ECQTH3 Handle Blocking (Lock Off) Device, ECQL1 Padlocking Device ECPLD1 Padlocking Device ECPLD2 Lug Kit, 3-Pole, Subfeed or Feed thru Applications ECLK3150 Main Breaker Retainer Kit for EQ Load Centers ECMBR1 Main Breaker Retainer kit for Ultimate Load Centers ECMBR2 Riser Lug Kit ECRLK250 Ground Bar Kit, ECGB14 Add-A-Lock (Flush Lock) ECQFL1 1-36 Neutral Lug Kit, ECLK1-2 wire range — #2-1 AWG Cu or Al Filler Plate, ECQF3 Neutral Lug Kit, ECLK3 wire range — #1-300 MCM Neutral Lug Kit, ECLK2 wire range — #4-#2/0 AWG Cu or Al Add-A-Lock (Flush Lock), ECQFL2 Ultimate Load Center For use on Ground Bar only Collar Strap, Wire Range; ECCS1; ECCS2 Mechanical Interlock ECQML12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Add-A-Lock (Flush Lock), ECQFL3 300-400A Load Centers All-Sites™ Temporary Power Outlet Panels Power Outlet Panel Types Available General 1 LOAD CENTERS & CIRCUIT BREAKERS Surface Earth Mount Pedestals Pad Mount Pedestals ▪ Unmetered ▪ Ring Type Metered (Meter at top or bottom) ▪ Unmetered ▪ Ring Type (Metered) ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Ringless Metered (Meter at top or bottom) ▪ Lighted Ringless Type (Metered) Lighted Cable and Telephone Water Unmetered Ring Type (Metered) Ringless Type (Metered) Lighted Cable and Telephone Water Back to Back Earth Mount Pedestals Back to Back Pad Mount Pedestals ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Unmetered Ring Type (Metered) Ringless Type (Metered) Lighted Cable and Telephone Water Unmetered Ring Type (Metered) Ringless Type (Metered) Lighted Cable and Telephone Water Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-37 LOAD CENTERS & CIRCUIT BREAKERS 1 All-Sites™ Temporary Power Outlet Panels Product Features Enclosures Rainproof Rainproof NEMA Type 3R construction. Quality Finish All sheet metal components are powder coated with the highest quality finish and fabricated with G90 galvanized steel. Installation Ease Three raised mounting embosses make installation a snap. Removable Deadfronts Easily removable upper and lower deadfronts allow easy access to internal components for ease of installation. Theft Resistant The padlock provisions and elevated upper deadfront design prevent unauthorized removal of the plugs or access to the circuit breakers. Meters Top or Bottom Metered units are available with meters at the top or bottom. ▪ Ring and ringless type meter covers available. ▪ Utility grade, Landis & Gyr meter socket base. ▪ Units with meter at bottom are ideally suited for underground feeds. ▪ Meter sockets available to 125 amps maximum. Removable Door Sloped door allows additional room for plugs, and is designed with aesthetic forms to add rigidity and sturdiness. Overhead/Underground Feeds Surface devices have provisions for overhead and underground feeds. ▪ For an overhead feed, use a readily available Type RX interchangeable hub. Closure plate is factory included. ▪ For an underground feed, an extensive variety of easily removable knockouts are provided. Light Option Lighted option to assist with nighttime site location and operation. Light provisions are the longest lasting and have the lowest operating cost in the industry. 1-38 Features Pedestals Interiors One-Piece Construction Rigid, one-piece pedestal construction for all earth and pad mounted devices. Thoroughly tested for torsion and flexing resistance. GFCI Protection All 125 volt, 20 amp receptacles have GFCI protection. Siemens GFCI circuit breakers are available to provide protection for 20-50 amp receptacles. Block Assembly Loop-feed block assembly provides connectors capable of accepting up to 350 kcmil conductors. (Available on pedestal devices only) Wire Connectors All wire connectors are suitable for use with copper or aluminum wire. (not shown) (continued) Pad Mount Pad mounted devices are available. (not shown) Interiors Bus Bars Plated copper bus bars provide the best protection against corrosion. Copper Conductors Ready to use! All internal components are factory prewired with copper conductors. Circuit Protection All receptacles are protected by lifetime warranted Siemens circuit breakers. Receptacles Impact-resistant, thermoplastic, commercial grade receptacles. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog All-Sites™ Temporary Power Outlet Panels Build Your Own Catalog Numbering System 1햲 2햲 3 5햲 4 Reference 6햲 7 8 9 10 1 P RECEPTACLE RECEPTACLE CONFIGURATION햶햷 1 14 - 50R 125/250V 50A 14 - 30R 125/250V 30A TT30R 125V 1F 2 2F 3 L6 - 30R 250V 30A 6 - 20R 250V 20A L5 - 20R 125V 20A 5 - 20R2GFI 125V 20A 4F 5 5F 6F GFCI 5 - 20R2 125V 20A L5 - 30R 125V 30A 9 9F 햲 햳 햴 햵 햶 햷 TYPE S= Surface P= Pedestal (Earth Mount) M= Pedestal (Pad Mount) 2B= Pedestal (Back-toBack, Earth Mount) 2M= Pedestal (Back-toBack, Pad Mount) L햴 Lighted EXAMPLE 1: (Catalog No. P1F38FTPXL) 4 8F METER U= Unmetered RT=Metered Ringless Type (Meter at top) T= Metered Ring Type (Meter at top) RB=Metered Ringless Type (Meter at bottom) B= Metered Ring Type (Meter at bottom) W햳 Water Required fields. For use on Pedestal Devices. All lighted devices require either a 5-20R2GFI receptacle or a QF120 circuit breaker. For use on unmetered or top metered devices. Devices with two outlets with a total amperage of 60 amps or less have factory ready provisions for an additional 1-pole circuit breaker. Devices with three outlets with a total amperage of 100 amps or less have factory ready provisions for an additional 1-pole circuit breaker. Up to 3 receptacles, and up to 125 Amps maximum permissible. The “F” next to the receptacle number denotes GFCI circuit breaker protection. K햵 Extra 1-Pole Circuit Breaker Provisions 30A 3F 7 X햳 Cable and Telephone RECEPTACLE LOAD CENTERS & CIRCUIT BREAKERS RECEPTACLE EXAMPLE 2: (Catalog No. P5F8FUS) Given specifications: Given specifications: ▪ 50A, 125/250V receptacle with GFCI circuit breaker ▪ 30A, 125V receptacle with a standard circuit breaker ▪ 20A, 125V receptacle with GFCI circuit breaker ▪ Ring type meter at the top ▪ Pedestal mount device ▪ Cable and telephone provisions ▪ Light option ▪ 20A, 125V receptacle with GFCI circuit breaker ▪ 20A, 250V receptacle with GFCI circuit breaker ▪ Unmetered ▪ Surface device Step 1 Start with the power receptacle product line prefix identifier: (P) Step 2 Choose the first receptacle and its circuit breaker type: (1F) Step 3 Choose the second receptacle and its circuit breaker type: (3) Step 4 Choose the third receptacle and its circuit breaker type: (8F) Step 5 Choose the utility grade meter type: (T) Step 6 Choose device mounting type: (P) Step 7 We have a variety of options you can add to your panel, including cable and telephone, and water. Add cable and telephone option here: (X) Step 8 Add the light option here: (L) Step 1 Start with the power receptacle product line prefix identifier: (P) Step 2 Choose the first receptacle and its circuit breaker type: (5F) Step 3 Choose the second receptacle and its circuit breaker type: (7) Step 4 Choose the utility grade meter type: (U) Step 5 Choose device mounting type: (S) Remember If the power outlet panel you need is not listed, you can build your own catalog number using these three basic guidelines: ▪ No more than three receptacles per device ▪ Total receptacle amperage may not exceed more than 125 amps ▪ The receptacles must be configured following a top to bottom sequence from the catalog numbering system seen on this page Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-39 All-Sites™ Temporary Power Outlet Panels Selection LOAD CENTERS & CIRCUIT BREAKERS 1 Most Common Items—See Previous Page to Build Your Own Catalog Number Unmetered Surface Mount Devices Catalog Number List Price $ Meter Type Receptacle #1 Receptacle #2 P17US 382.00 Unmetered 14-50R (50A) 5-20R2GFI (20A) Receptacle #3 P77US 333.00 Unmetered 5-20R2GFI (20A) 5-20R2GFI (20A) N/A P1F7US 470.00 Unmetered 14-50R (50A) 5-20R2GFI (20A) N/A P137US 376.00 Unmetered 14-50R (50A) TT30R (30A) 5-20R2GFI (20A) P577US 364.00 Unmetered 6-20R (20A) 5-20R2GFI (20A) 5-20R2GFI (20A) P37US 321.00 Unmetered TT30R (30A) 5-20R2GFI (20A) N/A N/A Metered Surface Mount Devices Catalog Number Receptacle #1 Receptacle #2 P77TS List Price $ 447.00 Ring Type/Top Meter Type 5-20R2GFI (20A) 5-20R2GFI (20A) Receptacle #3 N/A P577TS 553.00 Ring Type/Top 6-20R (20A) 5-20R2GFI (20A) 5-20R2GFI (20A) P1F7TS 639.00 Ring Type/Top 14-50R (50A) 5-20R2GFI (20A) N/A P77RTS 442.00 Ringless/Top 5-20R2GFI (20A) 5-20R2GFI (20A) N/A P1F7RTS 637.00 Ringless/Top 14-50R (50A) 5-20R2GFI (20A) N/A P5F7TS 637.00 Ring Type/Top 6-20R (20A) 5-20R2GFI (20A) N/A P77BS 427.00 Ring Type/Bottom 5-20R2GFI (20A) 5-20R2GFI (20A) N/A P177RBS 612.00 Ringless/Bottom 14-50R (50A) 5-20R2GFI (20A) 5-20R2GFI (20A) P77RBS 578.00 Ringless/Bottom 5-20R2GFI (20A) 5-20R2GFI (20A) N/A P5F77RBS 729.00 Ringless/Bottom 6-20R (20A) 5-20R2GFI (20A) 5-20R2GFI (20A) P1F77RBS 729.00 Ringless/Bottom 14-50R (50A) 5-20R2GFI (20A) 5-20R2GFI (20A) P17RBS 549.00 Ringless/Bottom 14-50R (50A) 5-20R2GFI (20A) N/A Metered and Unmetered Pedestal Devices Catalog Number List Price $ Enclosure Type Meter Type Receptacle #1 P137UP 722.00 Pedestal Earth Mount Unmetered 14-50R (50A) P37UP 568.00 Pedestal Earth Mount Unmetered TT30R (30A) 5-20R2GFI (20A) P137RTP 805.00 Pedestal Earth Mount Ringless 14-50R (50A) TT30R (30A) P137TP Receptacle #2 TT30R (30A) Receptacle #3 5-20R2GFI (20A) N/A 5-20R2GFI (20A) 783.00 Pedestal Earth Mount Ring Type 14-50R (50A) TT30R (30A) 5-20R2GFI (20A) P1F37UML햳 1173.00 Pedestal Earth Mount Unmetered 14-50R (50A) TT30R (30A) 5-20R2GFI (20A) P137RT2B 1101.00 Pedestal Earth Mount Back to Back Ringless 14-50R (50A) TT30R (30A) 5-20R2GFI (20A) P137U2B 1170.00 Pedestal Earth Mount Back to Back Unmetered 14-50R (50A) TT30R (30A) 5-20R2GFI (20A) 1-40 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Temporary Power Outlet Panels Dimension Drawings Top 1 Standard Knockout Pattern .75” & 1” K.O. Bottom LOAD CENTERS & CIRCUIT BREAKERS RX The knockout diagram shown at left is to be referenced for all surface mount devices 9.50 9.50 .25” K.O. .75”, 1” & 1.5”K.O. 9.50 29.13 23.40 16.10 6.13 6.13 SURFACE 6.13 METERED SURFACE LIGHTED SURFACE 'A' 6.13 6.13 A N B A N B 84.63 77.38 19.25 19.25 GRADE GRADE 24.00 24.00 METERED LIGHTED PEDESTAL METERED PEDESTAL Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-41 Temporary Power Outlet Panels Dimension Drawings LOAD CENTERS & CIRCUIT BREAKERS 1 9.50 9.50 6.13 A N 47.50 B 19.25 53.38 6.13 A N UNMETERED LIGHTED PAD MOUNT PEDESTAL B 9.50 19.25 6.13 A N B 40.25 METERED PAD MOUNT PEDESTAL 19.25 UNMETERED PAD MOUNT PEDESTAL 1-42 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Temporary Power Outlet Panels Dimension Drawings 9.50 9.50 9.50 1 LOAD CENTERS & CIRCUIT BREAKERS 6.13 36.38 A N B 6.13 A N B 19.25 64.30 19.25 71.50 6.13 GRADE METER LIGHTED SURFACE GRADE 9.50 24.00 24.00 UNMETERED PEDESTAL 27.88 UNMETERED LIGHTED PEDESTAL 9.50 6.13 METER AT BOTTOM SURFACE 12.50 A N B 43.25 19.25 UNMETERED PAD MOUNT BACK-TO-BACK-PEDESTAL Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-43 Temporary Power Outlet Panels Dimension Drawings 9.50 LOAD CENTERS & CIRCUIT BREAKERS 1 9.50 12.50 A 12.50 A N B N B 87.63 80.38 19.25 19.25 GRADE GRADE 24.00 24.00 METERED LIGHTED BACK-TO-BACK PEDESTAL METERED BACK-TO-BACK PEDESTAL 9.50 9.50 12.50 A N B 12.50 A N B 19.25 74.50 19.25 GRADE GRADE 24.00 24.00 UNMETERED LIGHTED BACK-TO-BACK PEDESTAL 1-44 67.25 UNMETERED BACK-TO-BACK PEDESTAL Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Temporary Power Outlet Panels Dimension Drawings 9.50 1 9.50 LOAD CENTERS & CIRCUIT BREAKERS 12.50 A 12.50 A N B N B 87.63 80.38 19.25 19.25 GRADE GRADE 24.00 24.00 METERED LIGHTED BACK-TO-BACK PEDESTAL METERED BACK-TO-BACK PEDESTAL 9.50 9.50 12.50 A N B 12.50 A N B 19.25 74.50 19.25 67.25 GRADE GRADE 24.00 24.00 UNMETERED LIGHTED BACK-TO-BACK PEDESTAL UNMETERED BACK-TO-BACK PEDESTAL Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-45 LOAD CENTERS & CIRCUIT BREAKERS 1 Notes 1-46 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2SPEEDFAX TM 2007-2008 Meter Centers Contents Single and Multiple Meter Sockets General Information Bypass Type Meter Sockets 2-2 2-3 Commercial Meter Sockets 2-7 – 2-9 Accessories—Selection Knockout Diagrams 2-10 2-11 – 2-17 Meter Main and Meter Load Center Combinations Catalog Number Logic Surface Mount Meter Mains, 1ø, 3-Wire 120/240V AC 2-18 2-19 – 2-21 EUSERC-Approved Meter-Main & Meter-Load Centers 100 – 200A 2-22 EUSERC-Approved Meter-Load Centers 200 – 225A 2-23 EUSERC-Approved Meter-Load Centers 250A 2-24 EUSERC-Approved Meter-Load Centers 300 – 400A 2-25 Electricenter Accessories Dimensions, Wiring Schematics, Knockout Codes 2-26 2-27 – 2-37 Modular Metering Residential and Commercial Series Ratings Chart Service Entrance Modules—Selection 2-38 – 2-39 2-40 2-41 – 2-43 Residential Meter Modules—Ring and Ringless Style 2-44 – 2-45 Commercial Meter Modules 2-46 – 2-51 Wiring and Knockout Diagrams 2-52 – 2-69 Uni-Pak Meter Centers General Information 2-70 Ring Style Meter Centers (100,000A IR) 2-71 Ringless Style Meter Centers (100,000A IR) 2-72 Ring Style Meter Centers Lever Bypass 2-73 Uni-Pak Accessories 2-74 Wiring Diagrams—125A, 200A 2-75 Knockout Diagrams 2-76 – 2-80 Modular and Uni-Pak Metering Accessories 2-81 Modular Metering Replacement Parts Kits 2-82 Modular Meter Lug Data & Bus Duct Units 2-83 EUSERC—Commercial Type By Meter Main Combinations 2-84 EUSERC—Commercial Type By Load Center Combinations 2-85 EUSERC—Wiring Diagrams 2-86 EUSERC—Dimensions & Knockout Diagrams 2-87 Residential Commercial Industrial METER CENTERS 2-4 – 2-6 2 Residential Meter Sockets Meter Centers Meter Mounting Devices General METER CENTERS 2 General Information Materials: 16 gauge, galvanized steel, G-90 Block Material: Glass reinforced polyester Enclosures: NEMA 3R Terminals: Residential - Tin-plated aluminum extrusions 6061-T6 Commercial - Tin-plated copper and or tin plated aluminum Finish: Steel - Light gray, baked on powder polyester Latches: All swing latches are stainless steel Siemens meter mounting devices utilize the high quality Landis & Gyr design known throughout the utility industry for more than 50 years. Siemens meter sockets are built for safety, ease of installation, and long term quality. That is why we use stainless steel hardware, polyester powder coat paint for long lasting protection, and Type G-90 galvanized steel for all of our enclosures. It is also why we use an all-copper current path in our commercial sockets. All of this means that the Siemens’ Landis & Gyr brand is recognized throughout the industry as the quality leader. Standards: Products cataloged herein meet or exceed the following standards: UL 486B, UL 414, NEMA 250, ANSI C12.7 UL File #30413 Accessories: All hubs, closure plates, and 5th terminals, if included, are factory installed. ▪ Residential single position sockets (types SUAT) feature a quad neutral as a standard feature ▪ Most commercial sockets include a ground lug & some models are available with line & load lugs installed ▪ Lever bypass sockets feature the Landis & Gyr type HQ socket which is recognized by utilities as the industry standard for durability & quality ▪ Siemens features one of the most complete and comprehensive meter socket lines available from any manufacturer Features: ▪ All enclosures feature type G90 galvanized steel with a durable polyester powder coat finish S40407-02CO 7-Jaw 3ø 4W 200 Amp Lever Bypass Type “HQ” 2-2 SUAS877-PPZA 4-Jaw 1ø 3W 200 Amp Residential Horn Bypass - Sidewire Design S48707-82GP 7-Jaw 3ø 4W 320 Amp Lever Bypass Type HQ - Sidewire Design Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog SUAT417-XG 4-Jaw 1ø 3W 200 Amp Residential No Bypass Meter Centers Meter Socket Bypass Types General There are several different bypass types used in the meter socket industry. The type of bypass used is dependent upon each individual utilities’ requirements for that application. The illustrations and photos below will explain some of the basic bypass types seen in section 2 of the Siemens’ speedfax. This page is meant for informative purposes only and is not meant to imply or convey the use of any particular bypass or inter-changing of any types of bypass for any application. The local utility should always be contacted to ensure approval of equipment prior to installation. The types of bypasses listed below are for utility use only. 2 Horn Bypass: Lever Bypass: A lever is used to rotate a plated copper blade between the line and load jaws. The Landis & Gyr lever bypass HQ socket also clamps on the meter when the bypass is dis-engaged. The bypass must be engaged to remove the meter then dis-engaged after the meter is installed. The bypass acts as an alternate path for current flow which helps to mitigate any arcing if the meter is being removed. This also ensures a constant current flow should the meter need to be removed. Test Block Bypass: Test Block Bypass sockets (TBB) have the line and load connectors mounted parallel to one another. This provides for a provision to bypass the meter by placing a jumper on the line and load bus. Note that this type of bypass is used primarily by those utilities subscribing to the EUSERC metering standards. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-3 METER CENTERS Small tabs or “horns” on the line and load side of the meter socket act as electrical connection points for the utility to install a bypassing means- usually a specially produced wire or “jumper” designed for this specific application. Meter Centers Single Position Meter Sockets—Residential Types METER CENTERS 2 Selection SUAT111-0PGP SUAT111-0MXA SUAT111-0GF 135 Amp Continuous Meter Mounting Equipment, Ringless Type, 1-Phase, 3-Wire 600V 1 Position Catalog Number HORN BYPASS SUAT111-0PZA SUAT111-0PDN SUAT111-0PGP SUAT111-0PQG NO BYPASS SUAT111-0JCA SUAT111-0G SUAT111-PG SUAT111-0MXA SUAT111-0GF Dimensions (inches) H W D Cont. Amps Service Lugs No. of Jaws 5th Jaw Hub KO Fig. 11.7 11.7 11.7 11.7 8.0 8.0 8.0 8.0 3.7 3.7 3.7 3.7 135 135 135 135 OH/UG OH/UG OH/UG OH/UG #14-2/0 #14-2/0 #14-2/0 #14-2/0 4 4 4 4 EC659-0121 EC659-0121 EC659-0121 EC659-0121 RX RX RX RX Opening Opening Opening Opening 1 1 1 1 11.7 11.7 11.7 11.7 11.7 8.0 8.0 8.0 8.0 8.0 3.7 3.7 3.7 3.7 3.7 135 135 135 135 135 OH/UG OH/UG UG OH/UG OH/UG #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 4 4 4 5 4 EC659-0121 EC659-0121 EC659-0121 Installed EC659-0121 RX Opening RX Opening None RX Opening RX Opening 1 1 1 1 1 Notes List Price $ 99.05 106.50 107.57 95.85 108.63 104.37 99.05 101.18 92.66 135 Amp Continuous Meter Mounting Equipment, Ring Type, 1-Phase, 3-Wire 600V 1 Position Catalog Number NO BYPASS SUAT121-0GWR SUAT121-BGWR SUAT121-PGWR SUAT121-BM SUAT121-0BCO SUAT121-BBCO SUAT121-PBCO Dimensions (inches) H W D Cont. Amps Service Lugs No. of Jaws 5th Jaw Hub KO Fig. 11.7 11.7 11.7 11.7 11.7 11.7 11.7 135 135 135 135 135 135 135 OH/UG OH UG OH OH/UG OH UG #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 4 4 4 5 5 5 5 EC659-0121 EC659-0121 EC659-0121 Installed Installed Installed Installed RX Opening EC38597 Inst. None EC38597 Inst. RX Opening EC38597 Inst. None 1 1 1 1 1 1 1 8.0 8.0 8.0 8.0 8.0 8.0 8.0 3.7 3.7 3.7 3.7 3.7 3.7 3.7 Notes List Price $ 103.31 106.50 99.05 103.31 108.63 107.57 108.63 Contact utility or sales office for approval by your local utility prior to installation. Includes 7/16" Barrel lock KO for utility security lock. Includes 7/8" Barrel lock KO for utility security lock. Stainless steel latch and hasp. All devices on this page come with a ground lug. Quad neutrals are standard on every SUAT1, SUAT3, & SUAT4 device. 2-4 Sealing ring included. For Duquense Light & Power. Approved for Florida Meter Group - overhead only. For use in the Consolidated Edison territory. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers Single Position Meter Sockets—Residential Types Selection 2 METER CENTERS SUAT317-0PGP SUAT417-XGF SUAS877-PPZA 200 Amp Continuous/250 Amp Max Meter Mounting Equipment, Ringless Type, 1-Phase, 3-Wire 600V 1 Position Catalog Number HORN BYPASS SUAT317-0PGP SUAT317-0PDN SUAT317-0FP SUAT317-0PZA SUAT317-0PQG SUAT317-0PCV SUAT417-XPQG SUAT417-XFP SUAT417-0PQG SUAS877-PPDN SUAS877-PPZA SUAS877-PPGP SUAS877-PPZ SUAS817-PPGP SUAS877-PPCV NO BYPASS SUAT317-0MXA SUAT317-0GF SUAT317-0G SUAT317-DGZ SUAT417-XGDU SUAT417-XGF SUAT417-XG SUAT417-PG SUAT517-PDG SUAT618-XGNM SUAS877-PG SUAS818-PGNM SUAS917-XJCA Dimensions (inches) H W D Cont. Amps Service Lugs (kcmil) No. of Jaws 5th Jaw Hub KO Fig. 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.0 14.0 14.0 14.0 14.0 14.0 8.0 8.0 8.0 8.0 8.0 8.0 11.0 11.0 11.0 13.0 13.0 13.0 13.0 13.0 13.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 5.1 5.1 5.1 5.1 5.1 5.1 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 OH OH OH OH OH OH OH/UG OH/UG OH/UG UG-SW UG-SW UG-SW UG-SW UG-SW UG-SW #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 4 4 5 4 4 4 4 5 4 4 4 5 4 4 4 EC659-0121 EC659-0121 Installed EC659-0121 EC659-0121 EC659-0121 EC659-0121 Installed EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 RX Opening RX Opening RX Opening RX Opening RX Opening RX Opening RX CL. Plate RX CL. Plate RX Opening None None None None None None 2 2 2 2 2 2 3A 3A 3A 6 6 6 6 8 8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 19.0 22.0 14.0 14.0 17.0 8.0 8.0 8.0 8.0 11.0 11.0 11.0 11.0 13.5 11.0 13.0 13.0 13.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 5.1 4.5 5.1 5.1 5.1 200 200 200 200 200 200 200 200 200 200 200 200 200 OH OH OH OH OH/UG OH/UG OH/UG UG UG OH/UG UG-SW UG-SW OH/UG-SW #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 5 4 4 4 4 4 4 4 4 4 4 4 4 Installed EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0120 EC659-0121 RX Opening RX Opening RX Opening EC38599 Inst. RX CL. Plate RX CL. Plate RX CL. Plate None None RX CL. Plate None None RX CL. Plate 2 2 2 2 3A 3A 3A 3B 4 5 6 8 7 Notes List Price $ 203.42 202.35 203.42 138.45 138.45 223.65 187.44 203.42 214.07 264.12 267.32 275.84 264.12 275.84 290.75 203.42 161.88 146.97 131.00 204.48 138.45 192.77 103.31 166.14 320.57 264.12 280.10 285.42 200 Amp Continuous/250 Amp Max Meter Mounting Equipment, Ring Type, 1-Phase, 3-Wire 600V 1 Position Catalog Number NO BYPASS SUAT327-0MCO SUAT327-0GWR SUAT427-PMCO SUAT427-XMWR Dimensions (inches) H W D Cont. Amps Service Lugs No. of Jaws 5th Jaw Hub KO Fig. Notes List Price $ 14.8 14.8 14.8 14.8 200 200 200 200 OH OH UG OH/UG #6-350 #6-350 #6-350 #6-350 5 4 5 4 Installed EC659-0121 Installed EC659-0121 RX Opening RX Opening None RX CL. Plate 2 2 3B 3A 140.58 123.00 174.66 161.88 8.0 8.0 11.0 11.0 4.5 4.5 4.5 4.5 Contact utility or sales office for approval by your local utility prior to installation. Includes 7/16" Barrel lock KO for utility security lock. Includes 7/8" Barrel lock KO for utility security lock. Stainless steel latch and hasp. A quad neutral is standard on all SUAT1, SUAT3, & SUAT4 devices. Device has line side studs. For use in the Niagra-Mohawk territory. Discount Schedule RESI Sealing ring included. For use in the Consolidated Edison territory. For use in the Florida Meter Group territory. “-SW” indicates an offset or side wire design. Meter is on right. May be used for overhead services in the EUSERC territories. Duquense Light & Power. “-SW” indicates an offset or side wire design. Meter is on left. For use on the Atlantic Electric & Delmarva Service areas only. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-5 Meter Centers Single & Multiple Position Meter Sockets—Residential Types METER CENTERS 2 Selection SUA2311-0PGP with EC659-0121 installed WSC250C SUA2717-YPGP 100 Amp/Position Meter Mounting Equipment, Ringless Type, 1-Phase, 3-Wire 300V Multi-Position Catalog Number HORN BYPASS SUA2311-0PGP SUA2311-0PQG SUA3311-0PGP SUA3311-0PQG SUA4311-0PGP SUA4311-0PQG Dimensions (inches) Bus H W D Amps Cont. Amps Service No. of Pos. No. of Jaws 12.0 12.0 12.0 12.0 12.0 12.0 100 100 100 100 100 100 OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG 2 2 3 3 4 4 4 4 4 4 4 4 24.0 24.0 32.0 32.0 40.0 40.0 4.5 4.5 4.5 4.5 4.5 4.5 100 100 135 135 180 180 5th Jaw EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 Hub Notes KO Fig. Line Lugs Load Lugs RX RX RX RX RX RX 16 16 17 17 18 18 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 Opening Opening Opening Opening Opening Opening List Price $ 324.83 347.19 455.82 477.12 590.01 610.25 200 Amp/Position Meter Mounting Equipment, Ringless Type, 1-Phase, 3-Wire 300V Multi-Position Dimensions (inches) Catalog Number HORN BYPASS SUA2717-YPDN SUA2717-YPGP SUA2717-YPQG SUA2717-YPZA SUA3717-YPDN SUA3717-YPGP SUA3717-YPZA SUA4719-YPDN SUA4719-YPGP SUA4719-YPQG SUA4719-YPZA SUA5719-KPGP SUA5719-KPDN SUA6719-KPQG SUA6719-KPZA H W D Bus Cont. Amps Amps 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 24.0 24.5 24.0 24.0 32.0 33.3 32.0 43.0 43.0 43.0 43.0 51.0 51.0 59.0 59.0 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 200 200 200 200 270 270 270 360 360 360 360 450 450 528 528 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 Service No. of No. of 5th Pos. Jaws Jaw Hub Notes OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG 2 2 2 2 3 3 3 4 4 4 4 5 5 6 6 HD Opening HD CL. Plate HD Opening HD Opening HD Opening HD CL. Plate HD Opening HD Opening HD CL. Plate HD Opening HD Opening 2-HD Opening 2-HD Opening 2-HD Opening 2-HD Opening 4 5 4 4 4 5 4 4 5 4 4 4 4 4 4 EC659-0121 Installed EC659-0121 EC659-0121 EC659-0121 Installed EC659-0121 EC659-0121 Installed EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 EC659-0121 Line KO Lugs Fig. (kcmil) 19 19 19 19 20 20 20 21 21 21 21 22 22 23 23 #1/0-600 #1/0-600 #1/0-600 #1/0-600 #1/0-600 #1/0-600 #1/0-600 (2)#1/0-600 (2)#1/0-600 (2)#1/0-600 (2)#1/0-600 (2)#1/0-600 (2)#1/0-600 (2)#1/0-600 (2)#1/0-600 Load Lugs List (kcmil) Price $ #6-350 337.61 #6-350 337.61 #6-350 358.91 #6-350 337.61 #6-350 498.42 #6-350 498.42 #6-350 498.42 #6-350 597.47 #6-350 597.47 #6-350 617.70 #6-350 597.47 #6-350 687.99 #6-350 772.13 #6-350 1082.04 #6-350 1082.04 100/80 Amp/Position Meter Mounting Equipment, Ring Type, 1-Phase, 3-Wire 300V Multi-Position Dimensions (inches) Catalog Number NO BYPASS WSC150C WSC250C WSC350C WSN251CR WSN351CR WSN451CR H W D Bus Cont. Amps Amps 11.3 11.3 11.3 13.5 13.5 13.5 15.3 30.5 45.5 16.8 25.5 34.1 3.8 3.8 3.8 4.1 4.1 4.1 200 200 200 80 80 80 100 100 100 Service No. of No. of 5th Pos. Jaws Jaw Hub OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG 1 2 3 2 3 4 1.25" KO 1.25" KO 1.25" KO RX CL. Plate RX CL. Plate RX CL. Plate 5 5 5 5 5 5 WSX019 WSX019 WSX019 Installed Installed Installed Notes Line KO Lugs Fig. (kcmil) Load Lugs List (kcmil) Price $ 24 25 26 30 31 32 #8-2/0 #8-2/0 #8-2/0 #8-2/0 #8-2/0 #8-2/0 #6-4/0 #6-4/0 #6-4/0 #6-250 #6-250 #6-250 165.00 330.00 497.00 404.70 588.95 773.19 Contact utility or sales office for approval by your local utility prior to installation. Unit Center Includes 7/16" Barrel lock KO for utility security lock. Includes 7/8" Barrel lock KO for utility security lock. For Duquense Light & Power. Ground lug included. (2) Ground lugs included. 2-6 Sealing ring included. is unbussed and indoor. feed. End feed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Devices are gangable. Use strap #WSX008M to gang devices together. For use in New York City only (Con Ed). Discount Schedule RESI Meter Centers Single Position Meter Sockets—Commercial/Industrial Types Selection 2 METER CENTERS S40405-02CO S40407-02CO S9804-9142 200 Amp Continuous Meter Mounting Equipment, Ringless Type, Lever Bypass, 1-Phase, 3-Wire Catalog Dimensions (inches) Number H W D 4 OR 5 TERMINAL S40404-02QG 19.0 13.0 5.0 S40405-02QG 19.0 13.0 5.0 S40405-015F 19.0 13.0 5.0 S42505-02RG 19.0 13.0 5.0 S40405-025 19.0 13.0 5.0 S40405-02CO 19.0 13.0 5.0 S40405-0BNU 28.0 13.0 5.0 S48805-0BNU 22.0 16.0 5.0 S44305-02CV 19.0 13.0 5.0 Cont. Amps Service Lugs No. of Jaws Hub Opening KO Fig. 200 200 200 200 200 200 200 200 200 OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG #6-350 kcmil #6-350 kcmil #6-350 kcmil 3/8-24 Stud #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil #6-350 kcmil 4 5 5 5 5 5 5 5 5 RX CL. Plate RX CL. Plate RX CL. Plate RX CL. Plate RX CL. Plate RX CL. Plate RX Opening RX CL. Plate HD CL. Plate 9 9 9 9 9 9 9 10 9 Notes List Price $ 431.00 478.19 473.93 463.28 459.02 459.02 448.37 548.48 578.00 200 Amp Continuous Meter Mounting Equipment, Ringless Type, Lever Bypass, 3-Phase, 4-Wire 600V Catalog Number 7 TERMINAL S40007-01GP S40407-02QG S40407-025 S40407-015F S40407-02CO S40407-01NU S9804-9142 S48807-02NU S44307-02CV Dimensions (inches) H W D Cont. Amps Service Lugs 17.0 19.0 19.0 19.0 19.0 19.0 20.0 22.0 19.0 200 200 200 200 200 200 200 200 200 OH OH/UG OH/UG OH/UG OH/UG OH/UG UG-SW OH/UG OH/UG #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 #6-350 10.0 13.0 13.0 13.0 13.0 13.0 16.0 16.0 13.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 kcmil kcmil kcmil kcmil kcmil kcmil kcmil kcmil kcmil No. of Jaws Hub Opening KO Fig. Notes List Price $ 7 7 7 7 7 7 7 7 7 RX Opening RX CL. Plate RX CL. Plate RX CL. Plate RX CL. Plate RX Opening RX CL. Plate RX CL. Plate HD CL. Plate 10 9 9 9 9 9 33 10 9 — 594.27 594.27 604.92 604.92 581.49 532.50 717.81 630.48 630.00 Contact utility or sales office for approval by your local utility prior to installation. Lugs For Includes 7/16" Barrel lock KO for utility security lock. Includes 7/8" Barrel lock KO for utility security lock. Stainless steel latch and hasp Ground lug included (2) Ground lugs included Discount Schedule RESI not included, order separately 5-jaw devices can be used for 3-phase 3-wire service if an isolated neutral kit is used. For use in the Florida Meter Group territory. For use in the Consolidated Edison territory. For use in the Northeast Utilities service area. use in the Atlantic Electric & Delmarva Service areas. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-7 Meter Centers Single Position Meter Sockets—Commercial/Industrial Types METER CENTERS 2 Selection S47704-02 S9817-8061 S48104-02 320 Amp Continuous/400 Amp Max Meter Mounting Equipment, Ringless Type, Lever Bypass, 1-Phase, 3-Wire Catalog Dimensions (inches) Number H W D 4 OR 5 TERMINAL S48704-82GP 34.0 20.0 6.0 S48104-02 31.0 16.0 5.0 S48504-92 28.0 13.0 5.0 S47604-81GP 28.0 13.0 5.0 S47704-02 28.0 14.0 6.0 S47704-01NU 28.0 14.0 6.0 S9804-9144 25.0 16.0 6.0 S9804-9146 34.0 20.0 6.0 S47605-02SP 28.0 13.0 5.0 S47705-01NU 28.0 14.0 6.0 S48105-83BU 31.0 16.0 5.0 S44704-8265 20.0 34.0 6.0 Cont. Amps Service Lugs No. of Jaws Hub Opening KO Fig. Notes List Price $ 320 320 320 320 320 320 320 320 320 320 320 320 OH/UG-SW OH/UG-SW UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG-SW OH/UG-SW #4-600 3/8-24 Stud 3/8-24 Stud #4-600 1/2-20 Stud 1/2-20 Stud 3/8-24 Stud 3/8-24 Stud 3/8-24 Stud 1/2-20 Stud #4-600 #4-600 4 4 4 4 4 4 4 4 5 5 5 4 HD CL. Plate HD CL. Plate None HD Opening HD CL. Plate HD Opening HD Opening HD CL. Opening HD CL. Plate HD Opening HD CL. Plate HD CL. Plate 11 14 35 12 13 13 13 11 12 13 14 11 719.94 1016.01 759.35 743.37 787.04 647.52 498.42 749.76 460.08 773.19 717.81 1135.29 320 Amp Continuous/400 Amp Max Meter Mounting Equipment, Ringless Type, Lever Bypass, 3-Phase, 4-Wire 600V Catalog Number 7 TERMINAL S47707-01NU S47707-02 S48707-82GP S9804-9145 S9804-9147 Dimensions (inches) H W D Cont. Amps Service Lugs No. of Jaws Hub Opening KO Fig. Notes 28.0 28.0 34.0 25.0 34.0 320 320 320 320 320 OH/UG OH/UG OH/UG-SW OH/UG OH/UG 1/2-20 Stud 3/8-24 Stud #4-600 3/8-24 Stud 3/8-24 Stud 7 7 7 7 7 HD HD HD HD HD 13 14 11 34 11 14.0 14.0 20.0 16.0 20.0 6.0 6.0 6.0 6.0 6.0 Opening CL. Plate CL. Plate Opening Opening List Price $ 773.19 773.19 870.11 634.74 890.34 400 Amp Continuous/400 Amp Max Meter Mounting Equipment, Ringless Type, No Bypass, 3-Phase, 4-Wire 600V Catalog Dimensions (inches) Cont. Number H W D Amps 7 TERMINAL - Landis & Gyr Type K7 Bolt-in Socket S9817-8061 34.0 20.0 6.0 400 Service Lugs No. of Jaws Hub Opening KO Fig. Notes List Price $ UG 1/2-20 Stud 7 HD CL Plate 15 1917.00 Contact utility or sales office for approval by your local utility prior to installation. Includes 7/16" Barrel lock KO for utility security lock. Includes 7/8" Barrel lock KO for utility security lock. Stainless steel latch and hasp. Ground lug included. (2) Ground lugs included. 2-8 Anti-inversion clip included. Lugs not included, order separately. Bolt-in meter socket. No bypass installed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Lugs should be chosen based on # of cables, size of wire, and size of stud. See accessories section for more information. “-SW” indicates offset or side wire design. Meter is on right. Discount Schedule RESI Meter Centers EUSERC Meter Sockets—Test Block Bypass & Transformer Rated Metering Selection 2 METER CENTERS MS44UTB MS14TB MS24TB Ring Type EUSERC-Approved Safety Sockets (Test Block Bypass) Catalog Number Dimensions (inches ) L W D MS14TB MS15TB MS17TB MS24TB MS25TB MS27TB 241⁄8 241⁄8 241⁄8 301⁄8 301⁄8 301⁄8 123⁄8 123⁄8 123⁄8 141⁄8 141⁄8 141⁄8 43⁄4 43⁄4 43⁄4 61⁄8 61⁄8 61⁄8 MS44UTB 341⁄2 153⁄8 61⁄4 Amps Cont. Duty 100 200 320 Service Hub No. of Jaws 5th Jaw 1ø-3W 3ø-3W 3ø-4W 1ø-3W 3ø-3W 3ø-4W RX RX RX RX HC RX 4 5 7 4 5 7 UX005B INSTALLED — UX001WL INSTALLED — 1ø-3W HD 4 — Wire Range Cu/AI #6-2/0 Box Lug #1/0-250 kcmil Lay-in Lug (2)1/0-250 kcmil or (1)#4-600 kcmil KO Fig. List Price $ 39 39 39 40 41 40 545.00 720.00 781.00 1017.00 1194.00 1343.00 44 2500.00 400 Ampere Transformer Rated CT-Meter Cabinet, (No Disconnect) 600V AC Max. Catalog Number Dimensions (inches) Height Width Depth No. of Jaws Hub KO Fig. 52.00 52.00 24.00 24.00 11.00 11.00 4 5 — — 42 42 1317.00 1329.00 52.00 24.00 11.00 8 — 42 1419.00 13 15 RX — 43 42 749.76 2192.00 List Price $ 1 Phase-3 Wire RTU121814 RTU121815 3 Phase-3 Wire RTU121818 3 Phase-3 Wire or 3 Phase-4 Wire RT121413 RTU122015 20.00 52.00 12.00 36.00 4.63 11.00 RTU121815 CT Mounting Bases-400 Amp Max. Catalog Number Service RT6019A RT6019HA RT6067A RT6067HA 1 1 3 3 Max. AIC Phase/3 Phase-3 Wire 10,000 Phase- 3 Wire 50,000 Phase- 4 Wire 10,000 Phase- 4 Wire 50,000 Wire Range (2) (2) (2) (2) NEMA NEMA NEMA NEMA Studs Studs Studs Studs List Price $ 356.00 447.00 665.00 779.00 Contact utility or sales office for approval by your local utility prior to installation. RT6019A Ground lug included. CT mounting base not included, order from chart below. Includes Test Switch mounting provision, and hub opening for overhead feed. Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-9 Meter Centers Accessories Selection H56476 H58852 2 H56732 METER CENTERS RX Hub H58022 S64685-1 Neutral Kit ECJS EC659-0121 S35815-2 SRSTD SRSS 5TH & 6TH Jaw Assemblies SRSW Interchangeable Hubs For Use With Catalog Number List Price $ All SUAxxxx single and multiple position sockets All SUAxxxx single and multiple position sockets All Lever Bypass single position sockets SC and SD Unbussed Multiple-5th Jaw Anti-Inversion clip for use with 320amp sockets when required EC659-0121-grounded EC659-0120-insulated S35815-2 WSX019 H59676 18.00 18.53 123.54 11.40 24.50 Description Catalog Number List Price $ Snap-On Type, aluminum Snap-On Type, steel Screw Type, aluminum SRSTD SRSS SRSW Description Miscellaneous Accessories Closure Plate Description Catalog Number Insulated Neutral Kit for “S404xx” sockets Isolated Neutral Kit for S9817-8061 Bypass Kit for S9817-8061 Jumper-200 Amp Rated-use on SUAxxx sockets only Plastic Meter Cover- Ring Plastic Meter Cover- Ringless Neutral Isolation kit for 200amp lever bypass sockets EC64685 S69685-1 S69623 ECJS ECPP ECCP3 64690-1 EC38594 EC38596 EC38597 EC38598 EC38599 EC38600 EC38595 03⁄4 1 11⁄4 11⁄2 2 21⁄2 — 22.90 37.81 37.81 23.96 23.96 107.57 38.34 ECHC200 ECHC250 ECHC300 ECHC000 2 21⁄2 3 — 72.00 108.00 175.00 24.00 EC56856 EC56857 EC56858 EC9747-1113 EC56933S 3 31⁄2 4 — — 178.92 263.06 119.28 28.76 76.68 HD CONDUIT HUBS 64.00 218.00 132.06 36.74 19.00 21.00 34.08 List Price $ HC CONDUIT HUBS Closure Plate List Price $ Hub Size (Inches) RX CONDUIT HUBS Sealing Rings 17.47 19.38 25.03 Catalog Number Adapter Plate convert HD to RX Closure Plate Lugs for Sockets with Stud Terminals햲 Catalog Number For Use With Wire Range List Price $ H58852 H56732 H56476 H58022 H55890 Line side of S9817 Socket on UG Applications Line & Load of S477 & Load/Neutral of S9817 Sockets Line & Load of S477 & Load/Neutral of S9817 Sockets Any socket with 3/8" Stud Terminals Any socket with 3/8" Stud Terminals (1) (2) (1) (2) (1) 47.50 35.00 44.00 33.00 22.00 햲 3/0-800 kcmil #4-350 kcmil 3/0-800 kcmil #6-250 kcmil #6-350 kcmil Each lug catalog number contains one lug unless otherwise noted. Order enough lugs to cover all terminations. 2-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers Knockout Diagrams Selection 2 METER CENTERS Figure 1 Figure 2 Figure 3 KNOCKOUTS (inches): Figure 3B Figure 4 䊎: A: B: L: N: P: R: S: X: Z: EE: GG: HH: AB: AC: AD: AE: AF: AG: AH: AI: HD: RX: 1/4 1/2 1/2, 3/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4, 1, 1-1/4 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 쏗2.750 HUB 0P Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-11 Meter Centers Knockout Diagrams METER CENTERS 2 Selection Figure 5 Figure 8 Figure 6 Figure 7 Figure 9 Figure 10 KNOCKOUTS (inches): Figure 11 2-12 Figure 12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 䊎: A: B: L: N: P: R: S: X: Z: EE: GG: HH: AB: AC: AD: AE: AF: AG: AH: AI: HD: RX: 1/4 1/2 1/2, 3/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4, 1, 1-1/4 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 쏗2.750 HUB 0P Meter Centers Knockout Diagrams Selection 2 METER CENTERS Figure 13 Figure 15 Figure 14 Figure 17 Figure 16 KNOCKOUTS (inches): Figure 18 Figure 19 䊎: A: B: L: N: P: R: S: X: Z: EE: GG: HH: AB: AC: AD: AE: AF: AG: AH: AI: HD: RX: 1/4 1/2 1/2, 3/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4, 1, 1-1/4 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 쏗2.750 HUB 0P Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-13 Meter Centers Knockout Diagrams METER CENTERS 2 Selection Figure 21 Figure 20 Figure 23 Figure 22 Figure 24 KNOCKOUTS (inches): Figure 25 2-14 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 䊎: A: B: L: N: P: R: S: X: Z: EE: GG: HH: AB: AC: AD: AE: AF: AG: AH: AI: HD: RX: 1/4 1/2 1/2, 3/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4, 1, 1-1/4 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 쏗2.750 HUB 0P Meter Centers Knockout Diagrams Selection 2 METER CENTERS Figure 26 Figure 27 Figure 28 KNOCKOUTS (inches): Figure 29 䊎: A: B: L: N: P: R: S: X: Z: EE: GG: HH: AB: AC: AD: AE: AF: AG: AH: AI: HD: RX: 1/4 1/2 1/2, 3/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4, 1, 1-1/4 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 쏗2.750 HUB 0P Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-15 Meter Centers Knockout Diagrams METER CENTERS 2 Selection Figure 30 Figure 31 Figure 33 Figure 32 KNOCKOUTS (inches):. Figure 34 2-16 Figure 35 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 䊎: A: B: L: N: P: R: S: X: Z: EE: GG: HH: AB: AC: AD: AE: AF: AG: AH: AI: HD: RX: 1/4 1/2 1/2, 3/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4, 1, 1-1/4 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 쏗2.750 HUB 0P Meter Centers Knockout Diagrams Selection KNOCKOUTS (inches): Figure 38 Figure 40 Figure 39 RX E E J Figure 41 Figure 42 J E J Figure 43 Figure 44 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-17 METER CENTERS Figure 37 1/4 1/2 1/2, 3/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4, 1, 1-1/4 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1/4, 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 쏗2.750 HUB 0P 2 Figure 36 䊎: A: B: L: N: P: R: S: X: Z: EE: GG: HH: AB: AC: AD: AE: AF: AG: AH: AI: HD: RX: Meter Centers Catalog Number Logic Combination Meter Sockets 30 40 B 1 200 S E C W METER CENTERS 2 MC Main Ampere Rating 1 = 1-Phase 3 = 3-Phase ML or L = Main Lug MB or B = Main Breaker Circuits (max. No. of circuits) Spaces (max. No. of 1" breakers) MM = Meter Main MC = Meter Load Center Combination 2-18 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog F/S = R= J= B= E= D/C = L= T= W= M= H= Flush / Surface Mounting Ringless (blank = ring type) 5th Jaw Horn Bypass EUSERC Approved UG Feed Only / OH/UG feed Lever Bypass Socket Feed Thru Lugs Wide Load Center Design Field Addable Sub Feed Main Double Hub Provision Meter Centers Surface Mount Meter Mains, 1-Phase, 3-Wire 120/240V AC UL listed MM0202ML1100S MM0202ML1125H 100A meter main (field added), OH feed only 125A meter main (field added) MM0406L1200X MM0202BXXX MM0404L1400RLM 200A meter main (field added), side hinge door 125 and 200A meter mains, side hinge door 400A meter main, side hinge door, provisions for two field installed mains Pad locking provisions on all devices Horn bypass and 5th jaw available as noted Side hinged door with one screw removal where shown Suitable for use only as service entrance equipment Contact local utility to confirm meter socket placement prior to installation 2 ▪ ▪ ▪ ▪ ▪ ▪ Selection MM0202B1XXXRJBX 125, 150, and 200A meter main (factory installed), side hinge door. METER CENTERS ▪ See end of section for dimensions and wiring diagrams Overhead/Underground 1-Phase, 3-Wire SN Meter Main Combinations Ampere Main Rating Breaker UL: Overhead/ No. of No. of UnderSpaces Circuits ground EUSERC: Overhead/ Short UnderCircuit ground Rating Dimensions (inches) Catalog Number Hub 5th Provision Jaw Height Width Depth RX 2-RX 2-RX 2-RX 2-RX 18.00 17.00 19.75 19.75 19.75 Cover Type List Foot Price $ Notes Main Breaker Field Installed 100 125 200 200 200 QP QP 1-QN/2-QP 1-QN/2-QP 1-QN/2-QP 2 2 4 4 4 2 2 6 6 6 OH OH OH/UG OH/UG OH/UG OH OH OH — — 10,000 22,000 22,000 22,000 22,000 MM0202ML1100S MM0202ML1125H MM0406L1200H MM0406L1200RH MM0406L1200RHJB 400 (2) QN(R), QN(R)H, QP, QPH 2 2 OH/UG — 22,000 MM0404L1400RLM HD — — OH — OH — — OH/UG OH/UG OH/UG 22,000 22,000 22,000 22,000 22,000 22,000 22,000 22,000 22,000 22,000 MM0202B1125RJB MM0202B1150RJB MM0202B1150 MM0202B1150R MM0202B1200 MM0202B1200R MM0202B1200RJB MM0202B1125RJBX MM0202B1150RJBX MM0202B1200RJBX EC5J EC5J EMC5J EMC5J Installed 7.375 16.00 17.125 17.125 17.125 4.00 5.00 5.00 5.00 5.00 Ring 366.00 1 Ring 498.00 Ring 965.00 Ringless 996.00 Ringless 1030.00 2 S35815-2 29.00 27.00 6.00 Ringless 2923.00 3 Installed Installed EMC5J EMC5J EMC5J EMC5J Installed Installed Installed Installed 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.14 5.14 5.14 Ringless Ringless Ring Ringless Ring Ringless Ringless Ringless Ringless Ringless Main Breaker Factory Installed 125 150 150 150 200 200 200 125 150 200 NEW Q2125H QN2150H QN2150H QN2150H QN2200H QN2200H QN2200H Q2125H QN2150H QN2200H 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG For inches / millimeters conversion, see Application Data section. RX RX RX RX RX RX RX RX RX RX 17.00 17.00 17.00 17.00 17.00 17.00 17.00 17.00 17.00 17.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 18.42 18.42 18.42 1752.00 1752.00 1736.00 1736.00 1752.00 1736.00 1752.00 1752.00 1752.00 1752.00 2 2 2 2, 3 2, 3 2, 3 햲 Shipped standard with two units per carton. Each unit supplied with 1.25" hub. Device has horn bypass. 햴 Devices with “X” suffix include an extra wide utility section. 햳 Listed by Underwriters‘ Laboratories, Inc., under file #E10703 vol. 1. Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-19 Meter Centers NEW METER CENTERS 2 Surface Mount Meter Load Centers, 1-Phase, 3-Wire 120/240V AC 150-200A Selection ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ UL listed Overhead and underground feed applications Underground feed accomplished by use of removable gutter trough Load wires bottom or back exit only 22,000 AIC rated Pad locking provisions on all devices Side hinge doors removable by backing out only one screw Suitable for use only as service entrance equipment RX type hub provision on top end wall HC type hub provision on bottom end wall Field addable 5th Jaw (EC5J2) Contact local utility to confirm meter socket placement prior to installation ▪ See end of section for dimensions and wiring diagrams MC0606L1200R (Shown) MC0606L1200RJB MC0606L1200RA MC0408B1150T (Shown) MC0408B1200T MC0408B1150RT MC0408B1200RT MC0816B1150CT (Shown) MC0816B1200CT MC0816B1150RCT MC0816B1200RCT MC2040B1150RC (Shown) MC2040B1200RC MC2040B1150RJBC MC2040B1200RJBC 200A, main lug, 6 circuit (Twelve 1" spaces), for use with up to six 2-pole breakers 150 or 200A, main breaker, four 1" spaces, feed thru lugs provided 150 or 200A, main breaker, eight 1" spaces, feed thru lugs provided 150 or 200A, main breaker, twenty 1" spaces provided Ampere Rating Main Breaker No. of Spaces 150 150 150 150 150 150 200 200 200 200 200 200 200 200 200 MBK150 MBK150 MBK150 MBK150 MBK150 MBK150 — — — MBK200 MBK200 MBK200 MBK200 MBK200 MBK200 4 4 8 8 20 20 12 12 12 4 4 8 8 20 20 No. of Circuits 8 8 16 16 40 40 6 6 6 8 8 16 16 40 40 Catalog Number Replaced Catalog Number Dimensions Height Width Depth Cover Type List Price $ Notes MC0408B1150T MC0408B1150RT MC0816B1150CT MC0816B1150RCT MC2040B1150RC MC2040B1150RJBC MC0606L1200R MC0606L1200RJB MC0606L1200RA MC0408B1200T MC0408B1200RT MC0816B1200CT MC0816B1200RCT MC2040B1200RC MC2040B1200RJBC MC0408MB1150T MC0408MB1150RT — — MC2040MB1150R — MC0606ML1200R MC0606ML12RB — MC0408MB1200T MC0408MB1200RT — — MC2040MB1200R — 30.0 30.0 32.0 32.0 36.0 36.0 27.0 27.0 27.0 30.0 30.0 32.0 32.0 36.0 36.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 Ring Ringless Ring Ringless Ringless Ringless Ringless Ringless Ringless Ring Ringless Ring Ringless Ringless Ringless 1318.00 1318.00 1387.00 1387.00 2540.00 2522.00 1188.00 1216.00 1250.00 1318.00 1318.00 1387.00 1387.00 2540.00 2522.00 3 3 3 3 3 3, 1, 1, 1, 3 3 3 3 3 3 Notes: 1. No main breaker provided. Accept QN or QP type 2 or 4-pole breakers. 2. Suitable for use as service entrance equipment when not more than six disconnecting means are provided and when not used as a lighting an appliance panel board. 2-20 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 5 2, 3 2, 3, 5 2, 3, 4 3. Due to wire space restrictions on the trough side, the left side of the interior is limited to a 60A max branch. 4. Aluminum enclosure. 5. Horn bypass and 5th jaw included. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers Surface Mount Meter Load Centers, 1-Phase, 3-Wire 120/240V AC 100-200A UL listed MC0816B1XXXH MC0816B1XXXT 200A OH/UG feed, 8 circuit, with feed thru lugs. 200A Trailer Panel, OH feed only, 8 circuits with feed thru lugs. MC2040B1150(R)/ MC2040B1200(R)/ MC1224B1125 MC0816B1400RLTM/ MC0816B1350RLTM 200A, 20 Circuit, Side by Side Meter Combo One factory installed main, provisions for up to 200A field installed main, 8 circuits. 22,000 AIC Rated Pad locking provisions on all devices Side hinge doors removable by backing out only one screw Suitable for use only as service entrance equipment Contact local utility to confirm meter socket approval prior to installation 2 ▪ ▪ ▪ ▪ ▪ ▪ ▪ Selection See end of section for dimensions and wiring diagrams METER CENTERS Overhead/Underground: 1-Phase, 3-Wire SN (22,000A IR) Meter Load Center Combinations UL: Overhead/ Ampere Main No. of No. of UnderRating Breaker Spaces Circuits ground 125 Q2125H 12 24 OH/UG 125 EQ9675R 12 24 OH/UG 150 QN2150RH 8 16 OH 150 QN2150RH 8 16 OH/UG 150 QN2150RH 8 16 OH/UG 150 QN2150RH 20 40 OH/UG 150 QN2150RH 20 40 OH/UG 200 QN2200RH 8 16 OH 200 QN2200RH 8 16 OH 200 QN2200RH 8 16 OH/UG 200 QN2200RH 8 16 OH/UG 200 QN2200RH 20 40 OH/UG 200 QN2200RH 20 40 OH/UG 350 QN2150H 8 16 OH/UG 400 NEW QN2200H 4 8 OH/UG 400 QN2200H 8 16 OH/UG 햲 햳 Feed thru lugs included. Side by side design for OH/UG applications. Discount Schedule RESI EUSERC: Overhead/ Underground — — — — — — — — — — — — — — — — 햴 Dimensions (inches) Hub Catalog Number Provision MC1224B1125 RX MC1224MB1125R HS MC0816B1150T RX MC0816B1150TH 2-RX MC0816B1150RTH 2-RX MC2040B1150 RX MC2040B1150R RX MC0816B1200T RX MC0816B1200RT RX MC0816B1200TH 2-RX MC0816B1200RTH 2-RX MC2040B1200 RX MC2040B1200R RX MC0816B1350RLTM HD MC0408B1400RLTM HD MC0816B1400RLTM HD 5th Jaw EMC5J EC5J — EMC5J EMC5J EMC5J EMC5J — — EMC5J EMC5J EMC5J EMC5J — — — Height 16.00 34.00 29.00 21.00 21.00 18.00 18.00 29.00 29.00 21.00 21.00 18.00 18.00 29.00 29.00 29.00 Width 22.89 14.12 12.00 22.89 22.89 22.89 22.89 12.00 12.00 22.89 22.89 22.89 22.89 27.00 27.00 27.00 Depth 5.00 5.00 5.12 5.00 5.00 5.00 5.00 5.12 5.12 5.00 5.00 5.00 5.00 6.00 6.00 6.00 Cover List Type Price $ Ring 1620.00 Ringless 1620.00 Ring 1387.00 Ring 1360.00 Ringless 1360.00 Ring 2585.00 Ringless 2522.00 Ring 1387.00 Ringless 1387.00 Ring 1360.00 Ringless 1360.00 Ring 2585.00 Ringless 2522.00 Ringless 3940.00 Ringless 3591.00 Ringless 3940.00 Foot Notes 2 2 1, 3 1, 3 1, 3 2 2 1, 3 1, 3 1, 2 1, 2 2 2 1 1 1 Over/under design for OH applications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-21 Meter Centers METER CENTERS 2 EUSERC Meter Main & Meter Load Centers (100-200A) Single Phase, 3-Wire 240V AC ▪ ▪ ▪ ▪ ▪ ▪ UL listed ▪ ▪ ▪ ▪ Side hinge door removable by backing out only one screw ▪ ▪ ▪ ▪ 5th jaw accessory available (ECMC5J) For overhead and underground feed applications Selection MM0406L1125SEC (shown) MM0406L1125FEC MM0406L1200SEC (shown) MM0406L1200FEC 125A Max, main lug meter main, between the studs construction 200A Max, main lug meter main, between the studs construction Designed to meet EUSERC standards 22,000 AIC Rated Pad locking provisions on all devices Surface and semi-flush units available - semi flush rails are depth adjustable for 2x6 studs Load wiring may exit top or bottom Suitable for use only as service entrance equipment RX type hub provision on top endwall, HC type hub provision on bottom endwall Ring type meter covers Contact local utility to confirm meter socket approval prior to installation See end of section for dimensions and wiring diagrams MC0816B1200SCTM (shown) MC0816B1200FCTM 200A Pump Panel, OH/UG Feed, 8 circuits with feed thru lugs, and provisions for up to 50A second main breaker Amps Max. 100 100 100 100 125 125 125 125 125 200 200 NEW 200 200 200 200 200 200 225 225 햲 Main Breaker Q2100H Q2100H Q2100H Q2100H Q2125H Q2125H Q2125H QP, QPH QP, QPH EQ9985 EQ9985 EQ9985 EQ9985 QN, QNH, QP, QPH QN, QNH, QP, QPH QN2200RH QN2200RH EQ9986 EQ9986 MC1224B1100SEC (shown) MC1224B1100FEC MC1224B1125SEC MC1224B1125FEC MC2442B1XXXSEC (shown) MC2442B1XXXFEC 100 and 125 Amp, 12 circuit, between the studs construction 200 and 225 Amp, 24 circuit, between the studs construction Mounting Flush Surface Flush Surface Flush Surface Flush Flush Surface Surface Flush Flush Surface Flush Surface Surface Surface Flush Surface No. of Spaces 12 12 16 16 12 12 16 4 4 8 8 24 24 4 4 30 40 24 24 Dimensions shown are representative of outside box length, width, and depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Dimensions are subject to change. 2-22 햳 햴 Max. Circuits 24 24 32 32 24 24 32 6 6 16 16 48 48 6 6 40 40 42 42 Service OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG Catalog Number MC1224B1100FEC MC1224B1100SEC MC1632B1100FEC MC1632B1100SEC MC1224B1125FEC MC1224B1125SEC MC1632B1125FEC MM0406L1125FEC햳 MM0406L1125SEC햳 MC0816B1200SCTM MC0816B1200FCTM MC2442B1200FEC MC2442B1200SEC MM0406L1200FEC햳 MM0406L1200SEC햳 MC3040B1200SECW햴 MC4040B1200SECW햴 MC2442B1225FEC MC2442B1225SEC Dimensions 햲 Height 269⁄16 269⁄16 309⁄16 309⁄16 269⁄16 269⁄16 309⁄16 269⁄16 269⁄16 409⁄16 409⁄16 409⁄16 409⁄16 309⁄16 309⁄16 321⁄4 321⁄4 409⁄16 409⁄16 MC4040B1200SECW (shown) MC3040B1200SECW 200A, Wide Load Center Design, Meter Combo Width 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 141⁄2 21 21 141⁄2 141⁄2 Depth 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 51⁄8 51⁄8 71⁄2 71⁄2 List Price $ 976.00 976.00 818.00 818.00 1668.00 1667.00 1743.00 515.00 515.00 1711.00 1711.00 2600.00 2600.00 1756.00 1804.00 2614.00 2923.00 2856.00 2856.00 Main breaker not included. FRK1 - Flush rail kit. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers NEW EUSERC Meter Load Center Combinations (200-225A) Single Phase, 3-Wire 240V AC ▪ ▪ ▪ ▪ ▪ ▪ ▪ UL listed ▪ ▪ ▪ ▪ ▪ Side hinge door removable by backing out only one screw Selection Designed to meet EUSERC standards Underground Feed Applications Only Load wiring may exit top or bottom 22,000 AIC Rated 2 Pad locking provisions on all devices METER CENTERS Surface and semi-flush units available - semi flush units are depth adjustable for 2x6 stud applications Suitable for use only as service entrance equipment HC type hub provision on bottom endwall 5th jaw accessory available Contact local utility to confirm meter socket approval prior to installation ▪ See end of section for dimensions and wiring diagrams MC1212L1200SED (shown) MC1212L1200FED MC3042B12XXFED (shown) MC3042B12XXSED MC2042B1200FED MC2042B1200SED Main lug device with provisions for up to six 2-pole breakers. Amps Max. 200 NEW 200 NEW 200 NEW 200 NEW 200 NEW 200 NEW 225 NEW 225 NEW Main Breaker NA NA MBK200A MBK200A MBK200A MBK200A MBK225A MBK225A Mounting Flush Surface Flush Surface Flush Surface Flush Surface No. of Spaces 12 24 20 20 30 30 30 30 Main breaker device with a 200 or 225A main, and provisions for 20 or 30 full 1" breaker provisions. Max. Circuits 12 12 40 40 42 42 42 42 Max. 2-Pole 6 6 10 10 14 14 14 14 Catalog Number MC1212L1200FED햲 MC1212L1200FED햲 MC2040B1200FED MC2040B1200SED MC3042B1200FED MC3042B1200SED MC3042B1225FED MC3042B1225SED Height 385⁄16 385⁄16 4113⁄16 4113⁄16 485⁄16 485⁄16 485⁄16 485⁄16 Dimensions 햲 Width 145⁄16 145⁄16 145⁄16 145⁄16 145⁄16 145⁄16 145⁄16 145⁄16 Depth 75⁄16 75⁄16 75⁄16 75⁄16 75⁄16 75⁄16 75⁄16 75⁄16 List Price $ 1376.00 1376.00 2600.00 2600.00 3140.00 3140.00 3366.00 3366.00 NEW The new ECTPD1 can be installed on meter combo’s listed on this page. It is a replacement door for the lower pull section that has a weatherproof GFCI receptacle cover햳. Use the receptacle for temporary power then carry it to the next job site, or leave it for customer use. ECTPD1 햲 Suitable for use as service entrance equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panel board. Discount Schedule RESI 햳 Consists of a door, hinges, and weatherproof cover. GFCI receptacle not included. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-23 Meter Combinations NEW EUSERC Meter Load Center Combinations (250A) Single Phase, 3-Wire 240V AC Selection General ▪ UL Listed ▪ Back to Back design – Meter section faces outdoor, load center METER CENTERS 2 faces indoor ▪ ▪ ▪ ▪ ▪ 250A max, 200A continuous rating Copper bussing and wiring forms 22,000 AIC rated Suitable for use only as service entrance equipment See end of section for dimensions and wiring diagrams Meter Section ▪ Designed to meet EUSERC standards ▪ Flush mounting enclosure, adjustable for 2x4 or 2x6 stud applications Load Center Trim/Cover ▪ Underground feed applications only ▪ Factory installed 200A main breaker, provisions for up to 50A max. secondary main breaker ▪ ▪ ▪ ▪ Pad locking provisions on all devices Side hinge doors removable by backing out only one screw HC type hub provision on bottom endwall Contact local utility to confirm meter socket approval prior to installation Load Center Section ▪ ▪ ▪ ▪ Load Center View Load wires top exit only Trim mounting tabs free up both hands for trim screw installation INSTA-WIRE™ neutrals Visible neutrals Side View 햲 햳 Meter Main View Main Ampere Rating햲 Main Breaker Type햲 Aux Breaker Max Ampere Rating Auxiliary Breaker Type햳 No. of Spaces No. of Circuits Dimensions Catalog Number Height Width Depth 200 200 QNH QNH 50 50 QP, QPH QP, QPH 24 30 42 42 MC2442B1250FE2 MC3042B1250FE2 473⁄8 473⁄8 143⁄8 143⁄8 73⁄4 73⁄4 List Price $ 2800.00 3360.00 Factory installed main breaker. Field installed main breaker, 2-pole only, 50A max rating. 2-24 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers NEW Meter Load Centers Single Phase, 3-Wire 240V AC Selection ▪ UL Listed ▪ 400A Max, 320A Continuous ▪ Meter socket options include 320A (400A max) lever bypass, nonbypass, test block bypass, and bolt on ▪ Load center options include a meter main, 8 space panel with feed through lugs, 24 space 2 22,000 AIC Rated Accepts HD Type Hubs METER CENTERS ▪ ▪ ▪ ▪ ▪ ▪ Factory installed flush mount option Surface mount devices accept field added flush rails Suitable for use only as service entrance equipment Contact local utility to confirm meter socket acceptance prior to installation Surface Mount 8 space, 16 circuit panel with factory installed 200A main and provisions for 2nd 60-200A field installed main Surface Mount Meter Main With Provisions for Two 60-200A Main Breakers ▪ See end of section for knock out diagrams and wiring schematics Accessories Surface Mount 24 space, 42 circuit panel with factory installed 400A Main Breaker Surface Mount 30 space, 42 circuit panel with factory installed 200A Main Breaker and Provisions for 2nd 60-200A Field Installed Main Catalog Number MM0404L1400SC MM0404L1400FD MM0404L1400SCS MM0404L1400FDS MC0816B1400SC Replaces New New New New New MC0816B1400FD New MC0816B1400SCS New MC0816B1400FDS New MC2442B1400SDB MC2442B1400SD MC3042B1400SD MC3042B1400SDB MC2442MB14B New MC3040MB21 MC3040MB22 MC3040MB21SS MC3040MB22SS MC3040MB22B MC3042B1400SDL MC3040MB22L MC3042B1400FD New MC3042B1400SC New MC3042B1400FDS New MC3042B1400SCS New MC3042B1400SDS Main Breaker (2) Field QP(H), QNR(H) (2) Field QP(H), QNR(H) (2) Field QP(H), QNR(H) (2) Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory JXD Factory JXD Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Factory QN2200RH Field QP(H), QNR(H) Description Flush Rail Kit for UG only devices Flush Rail Kit for OH/UG feed devices 2" HD Type Hub 2 1/2" HD Type Hub 3" HD Type Hub 3 1/2" HD Type Hub 4" HD Type Hub HD Closure Plate Snap on Sealing Ring Stainless Steel Screw Type Sealing Ring (2) #6-350 kcmil (1) #2-600 kcmil (2) 500-1000 kcmil Flush Mount Front View Catalog Number ECFRK1 ECFRK2 EC56854 EC56855 EC56856 EC56857 EC56858 EC56933S SRSS SRSW UK350TA UK600TA UK1000TA Spaces 4 4 4 4 8 Circuits 2 2 2 2 16 Mounting Surface Flush Surface Flush Surface Meter Socket Plug In Plug In Test Block Test Block Plug In Feed OH/UG UG OH/UG UG OH/UG Dimensions Height Width 3911⁄16 331⁄8 3911⁄16 301⁄8 3911⁄16 331⁄8 3911⁄16 301⁄8 3911⁄16 331⁄8 Depth 63⁄8 73⁄8 63⁄8 73⁄8 63⁄8 8 16 Flush Plug In UG 3911⁄16 301⁄8 73⁄8 8 16 Surface Test Block OH/UG 3911⁄16 331⁄8 63⁄8 8 16 Flush Test Block UG 3911⁄16 301⁄8 73⁄8 24 24 30 42 42 42 Surface Surface Surface Bolt In Plug In Plug In UG UG UG 3911⁄16 3911⁄16 3911⁄16 301⁄8 301⁄8 301⁄8 63⁄8 63⁄8 63⁄8 30 42 Surface Test Block UG 3911⁄16 301⁄8 63⁄8 30 42 Surface Bolt In UG 3911⁄16 301⁄8 63⁄8 30 42 Surface Lever Bypass UG 3911⁄16 301⁄8 63⁄8 30 42 Flush Plug In UG 3911⁄16 301⁄8 73⁄8 30 42 Surface Plug In OH/UG 3911⁄16 331⁄8 63⁄8 30 42 Flush Test Block UG 3911⁄16 301⁄8 73⁄8 30 42 Surface Test Block OH/UG 3911⁄16 331⁄8 63⁄8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-25 Meter Centers Electricenter Accessories Selection RX Type Hub 2 UX001WL METER CENTERS SRSTD MCJM HS Type Hub SRSW Interchangeable Hubs Conduit Size (Inches) Lbs. Grounding Bars (AI/Cu — except where noted) Catalog Number List Price $ ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 39.50 39.50 39.50 39.50 69.00 109.00 HS Type Hubs 3 ⁄4 1 11⁄4 11⁄2 2 21⁄2 Grounding bars are for use where grounding of electrical outlets and devices is by means of conductors. Each bar is equipped with large connectors rated for one #14-1/0 or, two or three #14-10 Cu/AI and small connectors rated for one #14-6 or, two #14-12 Cu/AI. (May be restricted by wire bending space.) Length RX Type Hubs 3 ⁄4 1 11⁄4 11⁄2 2 21⁄2 EC38594 EC38596 EC38597 EC38598 EC38599 EC38600 22.90 37.81 37.81 23.96 23.96 107.57 ECHV200 ECHV250 ECHV300 ECHV350 ECHV400 91.00 125.00 182.00 274.00 362.00 HV Type Hubs 2 21⁄2 3 31⁄2 4 ECHC200 ECHC250 ECHC300 Adapter Plate ECHCRXA EC9747-1113 (HD to RX) 22.50 28.76 Closure Plates ECHC000 ECHS000 ECHV000 EC38595 (RX Type) EC56933S (HD Type) 24.00 38.00 23.50 38.34 76.68 EC56856 EC56857 EC56858 List Price $ 0 4 ECLX068M 11.80 25⁄16 7 2 5 ECLX069M 15.60 31⁄2 11 3 8 ECLX071M 15.60 45⁄8 15 4 11 ECLX072M 17.70 53⁄4 19 5 14 ECLX073M 18.60 7 23 6 17 ECLX074M 25.50 81⁄8 27 7 20 ECLX075M 28.50 Catalog Number List Price $ Snap-on type, aluminum SRSTD 17.47 Screw type, aluminum SRSW 25.03 Miscellaneous Accessories Description HD Type Hubs 3 31⁄2 4 Catalog Number 4 Description 72.00 108.00 175.00 Accessories and Closure Plates Small 15⁄8 Sealing Rings HC Type Hubs 2 21⁄2 3 Number of Connectors Total Large 178.92 263.06 119.28 Catalog Number List Price $ Plastic Meter Opening Cover ECPP 19.00 Plastic Meter Cover Ringless ECCP3 21.00 NEMA Stud Mechanical Lugs (2) #6-350 kcmil (1) #2-600 kcmil Al/Cu (2) #500-1000 kcmil Al/Cu UK350TA UK600TA UK1000TA 55.00 49.50 64.00 5th jaw EMC5J 72.00 Neutral Feeder Lugs #2-1/0 ECLK1-2 13.90 #4-2/0 ECLK2 18.40 #1-350 kcmil ECLK3 24.00 Order 2-26 one for each phase and neutral. See catalog number tables for replacement main information for each meter combination. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers Dimensions and Wiring Schematics Selection 2 METER CENTERS MC0408B1150T / MC0408B1200T / MC0408B1150RT / MC0408B1200RT MC0606L1200 / MC0606L1200R / MC0606L1200RA 14.2 SERVICE DISCONNECT 50 AMP MAX 6.9 1 2 A2 B2 3 4 6 7 8 EQPT GRD 5 9 10 11 12 B1 A1 40.6 13 14 16 N1 (5X) L M MC0816B1150CT / MC0816B1200CT / MC0816B1150RCT / MC0816B1200RCT 4(X) A C N2 N4 G1 N3 MC0816B1200SCTM Knockout Code — Conduit Sizes 12.5 A = B = C = D = E = F = G= H = J = K = L = M= N= P = 5.3 RX HUB 29.0 K (2X) .31 J A3 B3 FEED THRU TERMINALS NEUTRAL 15 G ⁄2 ⁄2, 3⁄4 1 ⁄2, 3⁄4, 1 3 ⁄4, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2 3 ⁄4, 1, 11⁄4 1, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2, 21⁄2 11⁄4, 11⁄2, 2, 21⁄2, 3 1, 11⁄4, 2, 21⁄2, 3 3 ⁄8, 1⁄2, 3⁄4 3 ⁄4, 1, 11⁄4, 11⁄2, 2 1 ⁄4 2, 21⁄2, 3, 31⁄2, 4 1 1 MC0816B1200T / MC0816B1200RT Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-27 Meter Centers Dimensions and Wiring Schematics Selection 23.5 5.3 METER CENTERS 2 (2X) RX HUB H (3X) A (2X) G (4X) C (3X) .31 MC0816B1200TH / MC0816B1150RTH / MC0816B1200RTH (4X) B C 30.260 C (4X) B (2X) H (2X) H (11X) A (11X) A Service Disconnect (200A maximum) Service Disconnect (200A maximum) N B 9 8 16 A N Equipment Ground N1 (2X) C 9 (200A maximum) 8 16 N1 (16X) A (2X) C (2X) F (16X) A (2X) F (11X) B H 1 B 39.555 Neutral A Service Disconnect Service Disconnect (200A maximum) 1 Equipment Ground Test By-pass Neutral 39.555 Test By-pass (11X) B H MC0816B1400FDST MC0816B1400FDT 33.260 33.260 Service Disconnect (200A maximum) A Test By-pass N B Service Disconnect (200A maximum) 1 9 8 16 A 39.555 N (2X) C Equipment Ground N1 (16X) A (11X) B MC0816B1400SCST 2-28 9 8 16 B N1 (2X) C (2X) F H Service Disconnect (200A maximum) 1 Neutral Neutral 39.555 Test By-pass Service Disconnect (200A maximum) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog (16X) A (2X) F H (11X) B MC0816B1400SCT Equipment Ground 30.260 MC0816B1350RLTM / MC0816B1400RLTM Meter Centers Dimensions and Wiring Schematics Selection 2 METER CENTERS MC1212L1200FED 14.2 C RX Hub (2X) H 1 1 3.5 2 6.9 (2X) L 2 6.9 3 3 4 4 5 5 6 7 6 7 8 8 9 9 A2 B2 A2 10 10 B2 11 11 12 13 12 13 14 15 15 16 17 18 19 A1 B1 20 21 22 14.2 M G1 J (4X) A EQPT GRD ECGB5, ECGB10 or ECGB14 C MC1224B1100SEC Knockout Code — Conduit Sizes (2X) H 1 3.5 2 6.9 3 4 (2X) L 5 6 7 8 9 A2 B2 10 11 12 13 14 EQPT GRD 15 16 26.6 17 18 19 A1 B1 20 ECGB5 or ECGB10 only SERVICE DISCONNECT 23 24 (5X) L NEUTRAL 21 22 J N1 N2 G1 C M 23 24 (5X) L EQPT GRD ECGB5, ECGB10 or ECGB14 (3X) A ECGB5 or ECGB10 only SERVICE DISCONNECT MC1224B1100FEC (2X) N 20 21 22 N1 (4X)A C B1 SERVICE DISCONNECT N2 J 19 A1 NEUTRAL M 16 17 18 ECGB5 or ECGB10 only 23 24 (5X) L 26.6 EQPT GRD 26.6 14 EQPT GRD 14.2 NEUTRAL (3X) A (2X) N MC1212L1200SED N1 G1 N2 EQPT GRD ECGB5, ECGB10 or ECGB14 (4X)A C A = B = C = D = E = F = G= H = J = K = L = M= N= P = ⁄2 ⁄2, 3⁄4 1 ⁄2, 3⁄4, 1 3 ⁄4, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2 3 ⁄4, 1, 11⁄4 1, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2, 21⁄2 11⁄4, 11⁄2, 2, 21⁄2, 3 1, 11⁄4, 2, 21⁄2, 3 3 ⁄8, 1⁄2, 3⁄4 3 ⁄4, 1, 11⁄4, 11⁄2, 2 1 ⁄4 2, 21⁄2, 3, 31⁄2, 4 1 1 MC1224B1125FEC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-29 Meter Centers Dimensions and Wiring Schematics Selection 14.2 RX Hub 1 2 3 6.9 4 5 6 7 8 9 A2 B2 10 2 11 12 13 14 EQPT GRD METER CENTERS 15 16 26.6 17 18 19 A1 B1 20 ECGB5 or ECGB10 only SERVICE DISCONNECT 23 24 (5X) L M N1 G1 N2 EQPT GRD ECGB5, ECGB10 or ECGB14 J (4X) A C MC1224B1125 / MC1224B1125R (3X) A 14.2 (2X) N MC1224B1125SEC 14.2 C (2X) H RX Hub 3.5 6.9 (2X) L 30.6 30.6 (5X) L (5X) L M J M (4X)A C J (4X) A C MC1632B1100FEC (3X) A 14.2 (2X) N MC1632B1100SEC 14.2 C (2X) H RX Hub 3.5 6.9 6.9 (2X) L 30.6 30.6 J (5X) L (5X) L M M (4X)A C J (4X) A C MC1632B1125FEC 2-30 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEUTRAL 21 22 MC1632B1125SEC Meter Centers Dimensions and Wiring Schematics Selection 23.5 RX Hub 5.3 2 METER CENTERS 34.0 J H (3X) A (2X) G (4X) C (3X) .31 MC2040B1150 / MC2040B1150R / MC2040B1200 / MC2040B1200R MC2040B1150RC / MC2040B1150RJBC / MC2040B1200RC / MC2040B1200RJBC MC2040B1200FED MC2040B1200SED Knockout Code — Conduit Sizes 3.5 6.9 (2X)L 40.6 (5X)L M J (4X)A A = B = C = D = E = F = G= H = J = K = L = M= N= P = ⁄2 ⁄2, 3⁄4 1 ⁄2, 3⁄4, 1 3 ⁄4, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2 3 ⁄4, 1, 11⁄4 1, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2, 21⁄2 11⁄4, 11⁄2, 2, 21⁄2, 3 1, 11⁄4, 2, 21⁄2, 3 3 ⁄8, 1⁄2, 3⁄4 3 ⁄4, 1, 11⁄4, 11⁄2, 2 1 ⁄4 2, 21⁄2, 3, 31⁄2, 4 1 1 C MC2442B1200FEC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-31 Meter Centers Dimensions and Wiring Schematics Selection 14.2 RX Hub METER CENTERS 2 6.9 40.6 (5X) L M J (4X)A C MC2442B1200SEC MC2442B1250FE2 30.260 30.260 Service Disconnect Service Disconnect 1 A N 22 A N 1 22 21 42 B B 39.555 42 (2X) C Equipment Ground N1 N1 (16X) A (2X) C H 2-32 (11X) B (16X) A (2X) F (2X) F H (11X) B MC2442B1400SD MC2442B1400SDB MC3042B1200FED (shown) / MC3042B1225FED MC3042B1250FE2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Equipment Ground 21 Neutral Neutral 39.555 Meter Centers Dimensions and Wiring Schematics Selection C (4X) B 30.260 (2X) H (11X) A Service Disconnect (200A maximum) 21 42 B N1 (2X) C Equipment Ground Neutral N METER CENTERS A 22 (16X) A (2X) F (11X) B H MC3042B1200SED / MC3042B1225SED C MC3042B1400FD 33.260 (4X) B 30.260 (2X) H (11X) A Service Disconnect (200A maximum) Service Disconnect (200A maximum) Test By-pass Test By-pass N B Service Disconnect (200A maximum) 1 22 A N Service Disconnect (200A maximum) 1 22 21 42 B 39.555 39.555 21 (2X) C 42 N1 (16X) A Equipment Ground N1 (2X) C (2X) F H Equipment Ground Neutral Neutral A (16X) A (2X) F (11X) B H MC3042B1400FDS (11X) B MC3042B1400SC Knockout Code — Conduit Sizes 33.260 Service Disconnect (200A maximum) 39.555 Test By-pass N B Service Disconnect (200A maximum) 1 22 21 42 N1 (2X) C (16X) A (2X) F H (11X) B Equipment Ground Neutral A Test By-pass A = B = C = D = E = F = G= H = J = K = L = M= N= P = 2 39.555 Service Disconnect (200A maximum) 1 ⁄2 ⁄2, 3⁄4 1 ⁄2, 3⁄4, 1 3 ⁄4, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2 3 ⁄4, 1, 11⁄4 1, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2, 21⁄2 11⁄4, 11⁄2, 2, 21⁄2, 3 1, 11⁄4, 2, 21⁄2, 3 3 ⁄8, 1⁄2, 3⁄4 3 ⁄4, 1, 11⁄4, 11⁄2, 2 1 ⁄4 2, 21⁄2, 3, 31⁄2, 4 1 1 MC3042B1400SCS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-33 Meter Centers Dimensions and Wiring Schematics Selection 30.260 30.260 Service Disconnect (200A maximum) Service Disconnect (200A maximum) Service Disconnect (200A maximum) N A 39.555 N Equipment Ground N1 (2X) C (16X) A (16X) A (2X) F (2X) F H 42 B Neutral 42 N1 (2X) C 21 22 B 21 22 Neutral A 1 Equipment Ground 1 39.555 METER CENTERS H (11X) B MC3042B1400SD (11X) B MC3042B1400SDB 30.260 30.260 Lever By-pass Service Disconnect (200A maximum) Service Disconnect (200A maximum) Service Disconnect (200A maximum) 1 39.555 N 39.555 Test By-pass Test By-pass N B 21 42 Neutral Neutral 21 N1 42 (2X) C (16X) A (16X) A N1 (2X) F (2X) F H 22 B A (2X) C Service Disconnect (200A maximum) 1 Equipment Ground A 22 Equipment Ground 2 Service Disconnect (200A maximum) H (11X) B MC3042B1400SDL (11X) B MC3042B1400SDS 20.9 RX HUB 5.0 32.3 K (2X) M (11X) A (2X) L C MC4040B1200SECW 2-34 MM0202B1125RJBX / MM0202B1150RJBX / MM0202B1200RJBX Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Dimensions and Wiring Schematics Selection 2 METER CENTERS MM0202B1150 / MM0202B1200 / MM0202B1200R / MM0202B1200RJB F MM0202ML1100S 30.260 (11X) A (4X) B C (2X) H Service Disconnect (200A maximum) N B N1 Neutral A 39.555 Equipment Ground Service Disconnect (200A maximum) F (2X) H B MM0202ML1125H MM0404L1400FD 30.260 Knockout Code — Conduit Sizes (11X) A (4X) B C (2X) H Service Disconnect (200A maximum) N B 39.555 Service Disconnect (200A maximum) Equipment Ground Test By-pass N1 B (2X) H Neutral A Test By-pass A = B = C = D = E = F = G= H = J = K = L = M= N= P = ⁄2 ⁄2, 3⁄4 1 ⁄2, 3⁄4, 1 3 ⁄4, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2 3 ⁄4, 1, 11⁄4 1, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2, 21⁄2 11⁄4, 11⁄2, 2, 21⁄2, 3 1, 11⁄4, 2, 21⁄2, 3 3 ⁄8, 1⁄2, 3⁄4 3 ⁄4, 1, 11⁄4, 11⁄2, 2 1 ⁄4 2, 21⁄2, 3, 31⁄2, 4 1 1 MM0404L1400FDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-35 Meter Centers Dimensions and Wiring Schematics Selection 33.260 Service Disconnect (200A maximum) N METER CENTERS A B Equipment Ground 39.555 N1 (2X) H B MM0404L1400RLM MM0404L1400SC 33.260 14.2 (2X)N (2X)H 3.5 6.9 (2X)L Service Disconnect (200A maximum) N B Service Disconnect (200A maximum) Equipment Ground A Test By-pass N1 Neutral 39.555 Test By-pass 26.6 (5X)L M (2X) H B J MM0404L1400SCS (4X)A C (3X)A 14.2 RX Hub (2X)N MM0406L1125FEC 14.2 C (2X)H 3.5 6.9 6.9 (2X)L 26.6 30.6 (5X) L M (5X)L M J (4X) A C J MM0406L1125SEC 2-36 (4X)A C Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MM0406L1200FEC Neutral 2 Service Disconnect (200A maximum) Meter Centers Dimensions and Wiring Schematics Selection 14.2 RX Hub 6.9 2 METER CENTERS 30.6 (5X) L M GND J (4X) A C MM0406L1200SEC MM0406L1200H / MM0406L1200RH Knockout Code — Conduit Sizes A = B = C = D = E = F = G= H = J = K = L = M= N= P = ⁄2 ⁄2, 3⁄4 1 ⁄2, 3⁄4, 1 3 ⁄4, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2 3 ⁄4, 1, 11⁄4 1, 11⁄4, 11⁄2 1, 11⁄4, 11⁄2, 2, 21⁄2 11⁄4, 11⁄2, 2, 21⁄2, 3 1, 11⁄4, 2, 21⁄2, 3 3 ⁄8, 1⁄2, 3⁄4 3 ⁄4, 1, 11⁄4, 11⁄2, 2 1 ⁄4 2, 21⁄2, 3, 31⁄2, 4 1 1 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-37 Meter Centers METER CENTERS 2 Modular Metering: Introduction Siemens Modular Metering can be adapted to almost every requirement in residential and commercial group metering applications. The design of each module was completed with easy handling, fast installation, and simplified layout in mind. The complete line can be furnished for single phase three wire 120/240V AC and three phase, four wire 120/Y208V AC. Meter modules containing three phase thru bussing and three phase tenant mains are also rated for 240V AC Delta Systems. All service entrance devices are rated for 240V AC Max. The incoming utility service can be terminated in breaker, switch, or tap box “service entrance modules”. Tap boxes may be used when the total number of meters is 6 or less. For those areas that need to meet EUSERC requirements for underground feed a separate pullbox is available to attach to breaker devices up to 1200amps. Switch devices with an integral pullbox are available up to 800amps. All 200amp meter modules offer short circuit ratings up to 100,000A IR. Modules are available to meet the wide variety of bypass requirements from utilities nationwide including horn General bypass, lever bypass, and test block bypass. Residential modules (those with no bypass or horn bypass) are available in 2-6 positions. Commercial modules with a lever bypass are available in 1-4 positions. Commercial modules with a test block bypass are available in 1-3 positions. All 320amp meter modules offer short circuit ratings up to 42,000A IR if fully rated. Higher ratings may be achieved thru series ratings and are dependent upon the breaker used as the service disconnect. Residential Module Features Single Bolt Joint The time-saving single bolt joint (SBJ) provides for a single electrical connection between meter modules- a Siemens exclusive feature. The SBJ slips into one module with the adjacent unit being drawn towards it. The SBJ locks into place via a bracket on the back of each module- this keeps the SBJ stationary and is the primary means of grounding between modules. Beveled edges on the SBJ allow for easy positioning of the joint. Field installed studs are located just above and below the SBJ opening to compress the surrounding gaskets together to form a water-tight seal. For extra stability additional nuts and bolts are included as 2-38 a means of physically joining the meter stacks together both above and below the SBJ opening. Bus Construction Un-metered bus is surrounded by a barrier and all in-accessible bus connections are welded for maximum strength. All other connections- single bolt joint and meter socket connections, are bolted and accessible. Neutral & Ground Provisions Grounds and Neutrals are located on the bottom end of the meter modules. All grounds and neutrals may be relocated to the top of the enclosure if a top-exit is needed (A siemens exclusive feature). Each meter module has small indents to help locate a fieldcut knockout if a top exit is preferred. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Breaker Module Switch Module Pull Box Module Tap Box Module Lever Bypass Module Text Block Bypass Module Tenant Breaker Provisions Each single phase 200amp meter socket has a provision for a 4-pole plug-in type QPP circuit breaker. A 2-pole plug-in 125amp max may be used in these positions with the use of a filler plate. No other conversion kits are necessary for this transition. Each single phase 125amp meter socket has a provision for a 2-pole plug-in type QP circuit breaker. Each breaker is adjacent to each meter position. Generous gutter space allows for wiring from top, bottom, or back of the meter module. Each meter cover is embossed to provide a location for the unit (apartment) number. Meter Centers Modular Metering: Selection Information General 2 METER CENTERS Pullbox w/ Landing Lugs 1 Main Device 2 Spacer 햲 Meter Stack 3 4 Meter Stack Tap Box 5 6 A single bolt joint is required to connect all thru bussing. The application above requires (4) SBJ’s, one between each bussed module. Two SBJ’s would be included (one with each meter stack) and two would have to be purchased for the load side tap box and one for the spacer module to main breaker connection. Selection Information 햲 Pullboxes have provisions to field install lugs to accept incoming and outgoing conductors. The modules should be used for underground service feeds when inspecting authorities require the service to be split WMMB1400 or used in conjunction with a circuit breaker module when a EUSERC specification for underground feed is needed. Pullboxes are not meant for stand-alone use- they must be used with a service entrance breaker module. 햳 Most breaker and switch devices accept incoming feeds from the top or bottom. 400-800amp switches are invertible for top or bottom feed. 1200amp switches utilize a molded case switch (looks like a breaker) and are bottom feed only. Breaker modules are available in WMS44U separate top and bottom feed versions. A “BF” suffix on a breaker module catalog number designates bottom feed. Tap boxes may be used as a main when 6 or less meter positions are present. Tap boxes offer a direct connection to the thru bus with no overcurrent protection. Tap boxes are not 햲 intended to feed breaker or switch modules via the thru bus. Breaker, switch, and tap box modules do not come with a single bolt joint. 햴 A spacer is required between meter stack and main disconnect or tap box when installation is in EUSERC metering jurisdictions. The spacer can also be used to extend the length of the lineup when needed. WMEX1U 햵 Meter stacks should be selected to coincide with the number of meter positions required. All thru bussing must be the same as the service entrance device (all single phase or all three phase). Each stack comes with a WMM44AB200UR single bolt joint coupler and mounting rail. A single bolt joint coupler is needed for each thru bus connection. Utilities have varying requirements on height restrictions, cover types, and bypass types for each application therefore utility acceptance should be obtained prior to installation of any modules. 햶 Order a circuit breaker tenant main for each meter position. Circuit breakers must match phase of meter socket. Determine proper breakers from series rating chart. 2-Pole QPP 햷 Tapboxes allow for a direct connection to the thru bussing. This is typically used to feed meter modules when 6 or less meters are present, but it can also be used to feed remote equipment from a modular meter installation such as a current transformer cabinet. WMTB8U As this is un-metered power it is the installer’s responsibility to ensure utility approval prior to installation. Various accessories are available to help customize the products to fit your application. All breaker, switch, and tapbox modules include (2) thru bus cover plates (cat # WMEP) meant to cover the ends of the installation. Additional cover plates are available for order if needed. For applications using a load-side tap box or breaker module an additional single bolt joint coupler will be needed (cat #’s SBJ1 for single phase, SBJ4 for three phase). Other accessories can be found on page 2-81. Spacers are required between meter stack and main disconnect or tap box when installation is in EUSERC metering jurisdictions. Check with other utilities prior to installation. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-39 Meter Centers Modular Metering: Common Series Rating Charts Selection Use the tables below to determine the correct combination of equipment and circuit breakers for the available fault current. This chart provides series rating information for the most common applications. For a complete series rating chart please contact your local sales office. Residential / Commercial햲 2 Available Fault Current RMS Symmetrical Amps at 120/240 Volts Maximum METER CENTERS to 10,000 햴 Service Entrance햳 Modules Series MPOU, WMPOU MSU, WMSU MC, WMC MTBU, WMTBU 햵 to 22,000 햴 Series MSU, WMSU MC, WMC MTBU, WMTBU 햵 to 42,000 햴 Series MSU, WMSU MC, WMC 햲 MTBU, WMTBU to 65,000 햴 햵 Series MSU, WMSU MC, WMC MTBU, WMTBU 햵 to 100,000 Series MSU, WMSU MTBU, WMTBU 햵 Metering Branch Circuit Breakers Load Center Branch Circuit Breakers QP (15—125A) QPP (125—200A) QP, QPJ, QT, QPF, QE QP (15—125A) QPP (125—200A) QPH (15—125A) QPPH (125—200A) QPH (15—125A) QPPH (125—200A) QPH (15—125A) HQPP (125—200A) HQP (15—125A) HQPP (125—200A) QPH (15—125A) HQPP (125—200A) HQP (15—125A) HQPP (125—200A) HQPPH (100—200A) 2-pole HQPPH (100—200A) 2-pole QP, QPJ, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE Commercial Available Fault Current RMS Symmetrical Amps at 120/240 Volts Maximum 1-phase, 240 Volts Maximum 3-phase Service Entrance햳 Modules Series MPOU, WMPOU MSU, WMSU to 10,000 MC, WMC 햴 MTBU, WMTBU 햵 Series MSU, WMSU MC, WMC to 22,000 햴 MTBU, WMTBU 햵 Series MSU, WMSU MC, WMC to 42,000 햴 MTBU, WMTBU 햵 Series MSU, WMSU MC, WMC to 65,000 햴 MTBU, WMTBU 햵 Series MSU, WMSU to 100,000 MTBU, WMTBU햵 햲 This chart is applicable only with residential unified meter modules. (Siemens sockets, 1-phase outgoing) on pages 2-44 thru 2-45. 햳 MSU and WMSU fusible switch modules use Class T fuses only. MPOU and WMPOU pullouts also use Class T fuses. 2-40 햴 햵 Metering Branch Circuit Breakers QP (15—125A) 2-pole QP (15—100A) 3-pole QPP (125—200A) 2-pole QJ2 (60—200A) 3-pole QP (15—125A) 2-pole QP (15—100A) 3-pole QPP (125—200A) 2-pole QJ2 (60—200A) 3-pole QPH (15—125A) 2-pole QPH (15—100A) 3-pole QPPH (125—200A) 2-pole QJH2 (60—200A) 3-pole QPH (15—125A) 2-pole QPH (15—100A) 3-pole QPPH (125—200A) 2-pole QJH2 (60—200A) 3-pole QPH (15—125A) 2-pole QPH (15—100A) 3-pole HQPP (125—200A) 2-pole QJ2-H (60—200A) 3-pole HQP (15—125A) 2-pole HQP (15—100A) 3-pole HQPP (125—200A) 2-pole QJ2-H (60—200A) 3-pole QPH (15—125A) 2-pole QPH (15—100A) 3-pole HQPP (125—200A) 2-pole HQJ2H HQP (15—125A) 2-pole HQP (15—100A) 3-pole HQPP (125—200A) 2-pole HQJ2H HQPPH (100—200A) 2-pole HQJ2H HQPPH (100—200A) 2-pole HQJ2H Service entrance modules may not have suffix U in number. No overcurrent protection. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Load Center Branch Circuit Breakers QP, QPJ, QT, QPF, QE QP, QPJ, QT, QPF, QE QP, QPJ, QT, QPF, QE QP, QPJ, QT, QPF, QE QP, QT, QPF, QE QP, QPF, QE QP, QT, QPF, QE QP, QPF, QE QP, QT, QPF, QE QP QP, QT, QPF, QE QP QP, QT, QPF, QE QP, QT, QPF, QE QP, QT, QPF, QE QP, QP, QP, QP, QP, QT, QT, QT, QT, QT, QPF, QPF, QPF, QPF, QPF, QE QE QE QE QE Listed by Underwriters’ Laboratories, Inc., under file #E10848(N). Discount Schedule RESI Meter Centers Modular Metering: Circuit Breaker Service Entrance Modules Selection Features 햵 ▪ 65,000 AIC Rated, 100,000 AIC Available 햶 ▪ Devices available in top feed or bottom feed construction 햷 ▪ Alternate amperage units available 2 햸 ▪ All standard enclosures are Nema 3R rated ▪ Breaker modules include hanging bracket and end plates. Order extra single bolt joint coupler if used as a load side disconnect, see page 2-83 for accessories 400 Ampere Circuit Breaker Module 600 Ampere Circuit Breaker Module Check local utility requirements prior to installation. Circuit Breaker Modules Ampere Rating Maximum Interrupt Rating Outdoor Enclosure Top List Feed Price $ KO Fig. Bottom Feed List Price $ Dimensions (inches)햲 KO Fig. Breaker Type 햹 Line Terminal Lugs No. & Size Per Line & Neutral 햳 Height Width Depth 1-Phase, 3-Wire SN, Incoming, 120/240V AC Max. 400 65,000 WMC4 7015.00 A4A WMC4BF 7015.00 A4B JXD6 (2) #1-500 kcmil 33.00 15.09 15.00 600 65,000 WMC6 10640.00 A4C WMC6BF 10640.00 A4D LXD6 (2) #1-500 kcmil 37.00 15.09 15.00 700 65,000 WMC7 13395.00 A5A WMC7BF 13395.00 A5B MD6 (3) #1/0-500 kcmil 43.00 20.09 15.00 800 65,000 WMC8 13395.00 A5A WMC8BF 13395.00 A5B MD6 (3) #1/0-500 kcmil 43.00 20.09 15.00 1000 65,000 WMC10 18281.00 A6A WMC10BF 18281.00 A6B ND6 (4) #2-500 kcmil 50.00 20.09 15.00 1200 65,000 WMC12 26001.00 A6A WMC12BF 26001.00 A6B ND6 (4) #2-500 kcmil 50.00 20.09 15.00 1400 65,000 WMC14 35163.00 A7A WMC14BF 35163.00 A7B PD6 (5) 300-600 kcmil 62.00 24.88 16.48 1600 65,000 WMC16 35163.00 A7A WMC16BF 35163.00 A7B PD6 (5) 300-600 kcmil 62.00 24.88 16.48 3-Phase, 4-Wire SN, Incoming, 240V AC Max. 400 65,000 WMC44 8030.00 A4A WMC44BF 8030.00 A4B JXD6 (2) #1-500 kcmil 33.00 15.09 15.00 600 65,000 WMC64 12646.00 A4C WMC64BF 12646.00 A4D LXD6 (2) #1-500 kcmil 37.00 15.09 15.00 700 65,000 WMC74 16495.00 A5A WMC74BF 16495.00 A5B MD6 (3) #1/0-500 kcmil 43.00 20.09 15.00 800 65,000 WMC84 16495.00 A5A WMC84BF 16495.00 A5B MD6 (3) #1/0-500 kcmil 43.00 20.09 15.00 1000 65,000 WMC104 20725.00 A6A WMC104BF 20725.00 A6B ND6 (4) #2-500 kcmil 50.00 20.09 15.00 1200 65,000 WMC124 29119.00 A6A WMC124BF 29119.00 A6B ND6 (4) #2-500 kcmil 50.00 20.09 15.00 1400 65,000 WMC144햴 43048.00 A7A WMC144BF햴 43048.00 A7B PD6 (5) 300-600 kcmil 62.00 24.88 16.48 1600 65,000 WMC164햴 43048.00 A7A WMC164BF햴 43048.00 A7B PD6 (5) 300-600 kcmil 62.00 24.88 16.48 Ampere Rating Maximum Interrupt Rating Indoor Enclosure Top List Feed Price $ KO Fig. Bottom Feed List Price $ KO Fig. Breaker Type 햹 Line Terminal Lugs No. & Size Per Line & Neutral 햳 Height Width Depth 2000 65,000 MC20햴 A30A MC20BF햴 40631.00 A30B RD6 (5) 300-600 kcmil 62.00 24.88 16.48 햲 40631.00 Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, covers, hubs, or hardware protrusions. 햳 Wire range is the maximum allowable. 햴 1200amp maximum feed per side. 햵 Contact sales office for ordering information on 100K rated units. 10% adder applies. Discount Schedule RESI 햶 Devices are top or bottom, not combination. Both constructions use the same enclosure size and knockout patterns. 햷 Contact sales office for ordering information. Lead time may apply. Dimensions (inches)햲 햸 Bus Duct devices and 2000amp device are indoor, type N1, only. 햹 Breaker types listed are for top feed units. All bottom feed units use non-interchangeable trip breakers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-41 METER CENTERS 햸 ▪ Devices equipped for bus duct entry are available , see page 2-82 Meter Centers Modular Metering: Main Switch Service Entrance Modules Selection Features ▪ 400-800Amp Standard Switches (Non-EUSERC) are invertible for top or bottom feed ▪ 1200Amp device uses a molded case switch (looks like a breaker) 2 ▪ All switches are setup for class T fuses METER CENTERS ▪ 100,000 AIC Rating ▪ Small Compact Size ▪ Bus Duct entry available for 400-800Amp standard switches, see page 2-83 400 Ampere Fusible Switch Module 800 Ampere Fusible Switch & Pullbox Combination Module Check local utility requirements prior to installation. Fusible Switch Modules Ampere Rating Outdoor Enclosure Maximum Interrupt Catalog List Rating Number Price $ Fuse Type 햴 Dimensions (inches) 햲 Service Feed Line Terminal Lugs No. & Size Per Line & Neutral 햳 Height Width Depth KO Fig. 1-Phase, 3-Wire SN, Incoming, 120/240V AC Max. 200 100,000 WMP02U 햵 1343.00 T OH (1) #6-250 kcmil 33.00 12.00 13.00 A3 400 100,000 WMS4U 4086.00 T OH/UG (2) #4-500 kcmil 35.50 15.00 16.00 A1A 600 100,000 WMS6U 7762.00 T OH/UG (2) #4-500 kcmil 41.50 15.00 16.00 A1B 800 100,000 WMS8U 11895.00 T OH/UG (3) #4-500 kcmil 41.50 15.00 16.00 A1C 1200 100,000 WMS12U 햸 25514.00 T UG (4) #250-500 kcmil 50.00 20.00 15.00 A1D 3-Phase, 4-Wire SN, Incoming, 240V AC Max. 200 100,000 WMP024U햵 2043.00 T OH/UG (1) #6-250 kcmil 33.00 12.00 13.00 A3 400 100,000 WMS44U 4643.00 T OH/UG (2) #4-500 kcmil 35.50 15.00 16.00 A1A 600 100,000 WMS64U 9480.00 T OH/UG (2) #4-500 kcmil 41.50 15.00 16.00 A1B 800 100,000 WMS84U 17269.00 T OH/UG (3) #4-500 kcmil 41.50 15.00 16.00 A1C 1200 100,000 WMS124U 햸 28611.00 T UG (4) #250-500 kcmil 50.00 20.00 15.00 A1D Combination Fusible Switch & Pull Box Modules (Meets EUSERC Requirements) Ampere Rating Outdoor Enclosure Maximum Interrupt Catalog List Rating Number Price $ Fuse Type Service Feed Line Terminal Lugs No. & Size Per Line & Neutral Dimensions (inches)햲 Height Width Depth KO Fig. 1-Phase, 3-Wire SN, Incoming, 120/240V AC Max. 400 100,000 WMS4UPBU 5005.00 T UG 1 Set of 2 Studs 50.06 25.50 15.00 A2A 600 100,000 WMS6UPBU 9260.00 T UG 2 Set of 2 Studs 50.06 25.50 15.00 A2A 800 100,000 WMS8UPBU 13374.00 T UG 3 Set of 2 Studs 50.06 25.50 15.00 A2A A2A 3-Phase, 4-Wire SN, Incoming, 240V AC Max. 400 100,000 WMS44UPBU 6842.00 T UG 1 Set of 2 Studs 50.06 25.50 15.00 600 100,000 WMS64UPBU 12161.00 T UG 2 Set of 2 Studs 50.06 25.50 15.00 A2A 800 100,000 WMS84UPBU 20000.00 T UG 3 Set of 2 Studs 50.06 25.50 15.00 A2A 햲 Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, covers, hubs, or hardware protrusions. 햳 Wire range listed is the maximum allowable. 2-42 햴 Fuses not included. Fusible pull-out switch. 햷 Lugs not included. NEMA II Stud Pattern lugs must be installed by user or utility. 햵 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햸 Device uses a molded case switch (looks like a breaker). Class T fuses must be installed in conjuction with the molded case switch for proper operation. Discount Schedule RESI Meter Centers Modular Metering: Tap Box and Pullbox Modules Selection Features Tap Boxes ▪ 1200Amp thru bussing included for line side feed or load side tap and are invertible for top or bottom feed ▪ 100,000 AIC Rating 2 ▪ Compact Construction ▪ EUSERC-compliant construction for cable entry and exit (no thru bus connection) ▪ Can be used with breaker modules (up to 1200amps) for EUSERC compliance for underground feed or when extra conductor length needed (aligns with 6" KO on both modules) Tap Box Module Pullbox Module ▪ 65,000 AIC Rating Check local utility requirements prior to installation. Tap Box Modules햴 Ampere Rating Outdoor Enclosure Maximum Interrupt Catalog List Rating Number Price $ Service Feed Line Terminal Lugs No. & Size Per Line & Neutral 햳 Dimensions (inches)햲 Height Width Depth KO Fig. 1-Phase, 3-Wire SN, Incoming, 120/240V AC Max. 800 100,000 WMTB8U 1507.00 OH/UG (3) 1/0-400 kcmil 39.00 12.00 12.00 A2 1200 100,000 WMTB12U 2274.00 OH/UG (4) 250-600 kcmil 41.00 15.00 13.00 A8 1600 100,000 WMTB16U 4877.00 OH/UG (5) 300-600 kcmil 41.75 25.00 14.00 A9 3-Phase, 4-Wire SN, Incoming, 240V AC Max. 800 100,000 WMTB84U 1632.00 OH/UG (3) 1/0-400 kcmil 39.00 12.00 12.00 A2 1200 100,000 WMTB124U 2538.00 OH/UG (4) 250-600 kcmil 41.00 15.00 13.00 A8 1600 100,000 WMTB164U 5277.00 OH/UG (5) 300-600 kcmil 41.75 25.00 14.00 A9 Pullbox Modules (no thru-bus, includes lug landings) Ampere Rating Outdoor Enclosure Maximum Interrupt Catalog List Rating햵 Number Price $ Service Feed Line Terminal Lugs No. & Size Per Line & Neutral Dimensions (inches)햲 Height Width Depth KO Fig. 1-Phase, 3-Wire SN, Incoming, 120/240V AC Max. 400 65,000 WMMB1400 1382.00 UG 1 Set of 2 Studs 37.50 16.69 9.34 A10A 800 65,000 WMMB1800 1534.00 UG 2 Sets of 2 Studs 45.50 19.44 12.72 A10B 1200 65,000 WMMB11200 3186.00 UG 3 Sets of 2 Studs 47.50 25.94 12.72 A10C 3-Phase, 4-Wire SN, Incoming, 240V AC Max. 400 65,000 WMMB3400 2191.00 UG 1 Set of 2 Studs 37.50 16.69 9.34 A10A 800 65,000 WMMB3800 2763.00 UG 2 Sets of 2 Studs 45.50 25.94 12.72 A10B 1200 65,000 WMMB31200 5749.00 UG 3 Sets of 2 Studs 47.50 33.83 12.72 A10C 햲 Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. 햳 Wire range listed is the maximum allowable. Discount Schedule RESI 햴 햵 Single bolt joint coupler not included. If used for load side application an additional coupler must be ordered. Devices rated for 22,000. 65,000 rating requires cables to be tied together. Please see instructions with pullbox for details. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-43 METER CENTERS Pullboxes Meter Centers Modular Metering: Residential Modules—Ring Style Selection Features METER CENTERS 2 ▪ UL Listed for 60/75° C conductors. See equipment markings for applications ▪ 1200 Amp thru bus ▪ Interconnectable with discontinued “MM” modular metering ▪ Factory phased 3ø units saves on installation time ▪ 200A units UL Listed for use on systems capable of delivering up to 100,000 RMS symmetrical amperes maximum short circuit current ▪ Single bolt joint coupler included. Order additional couplers as needed. Use closure plates from main device to seal openings on side for thru bus. WMM4U Four Socket Module WMM6U Six Socket Module Main Breaker Panel Series Tested Systems — Specify Siemens Modular Metering equipment in conjunction with Ultimate Load Centers. Check local utility requirements prior to installation. 1-Phase, 3-Wire SN, Incoming & Outgoing, Ring Type Gangable Meter Stack Continuous Duty Amps Per Position Meter Positions Per Stack Dimensions햲 Catalog Number List Price $ Breaker Provision Maximum AIC햶 Height Width Depth Field Intalled 5th Jaw Assembly햵 KO Fig. 1-Phase 4-Jaw Sockets, 1 Phase-3 Wire Thru-Bus 120/240V AC Max. 125 200 2 WMM2U 1417.00 65,000 32.41 13.44 7.84 ECMM5J A12 3 WMM3U 1587.00 65,000 41.41 13.44 7.84 ECMM5J A12 4 WMM4U 2083.00 QP, QPH, 65,000 50.41 13.44 7.84 ECMM5J A13 5 WMM5U 2684.00 HQP 65,000 59.41 13.44 7.84 ECMM5J A14 6 WMM6U 3301.00 2 WMM2200U 3157.00 3 WMM3200U 3379.00 HQPP, HQPPH, 100,000 47.41 17.44 7.84 ECMM5J A17 4 WMM4200U 4657.00 QP, QPH, HQP 햳 100,000 58.41 17.44 7.84 ECMM5J A18 QPP, QPPH, 65,000 68.41 13.44 7.84 ECMM5J A15 100,000 36.41 17.44 7.84 ECMM5J A16 3-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, Ring Type Gangable Meter Stacks Continuous Meter Duty Amps Positions Catalog Per Position Per Stack Number List Price $ Breaker Provision Dimensions햲 Maximum AIC햶 Height Width Depth 1-Phase 5-Jaw Sockets, 3 Phase-4 Wire Thru-Bus 208Y/120V AC 125 200 햲 Stack Phasing: Phases/Socket KO Fig. 햴 3 WMM34U 1688.00 65,000 41.41 13.44 7.84 Installed 1-AB, 1-BC, 1-CA A12 4 WMM44ABU 2254.00 65,000 50.41 13.44 7.84 Installed 2-AB, 1-BC, 1-CA A13 4 WMM44BCU 2254.00 QP, QPH, 65,000 50.41 13.44 7.84 Installed 2-BC, 1-AC, 1-AB A13 4 WMM44CAU 2254.00 HQP 65,000 50.41 13.44 7.84 Installed 2-AB, 1-BC, 1-CA A13 5 WMM54ABU 2908.00 65,000 59.41 13.44 7.84 Installed 1-AB, 2-BC, 2-CA A14 6 WMM64U 3574.00 65,000 68.41 13.44 7.84 Installed 2-AB, 2-BC, 2-CA A15 2 WMM24AB200U 3208.00 100,000 36.41 17.44 7.84 Installed 1-BC, 1-CA A16 3 WMM34200U 3574.00 100,000 47.41 17.44 7.84 Installed 1-AB, 1-BC, 1-CA A17 4 WMM44AB200U 4556.00 QPP, QPPH, 100,000 58.41 17.44 7.84 Installed 2-AB, 1-BC, 1-CA A18 4 WMM44BC200U 4556.00 HQPP, 100,000 58.41 17.44 7.84 Installed 2-BC, 1-AC, 1-AB A18 4 WMM44CA200U 4556.00 HQPPH, 100,000 58.41 17.44 7.84 Installed 2-AB, 1-BC, 1-CA A18 5 WMM54AB200U 5315.00 QP, QPH, 100,000 69.41 17.44 7.84 Installed 2-AC, 2-BC, 1-AB A19 5 WMM54BC200U 5315.00 HQP 햳 100,000 69.41 17.44 7.84 Installed 2-AC, 2-AB, 1-BC A19 5 WMM54CA200U 5315.00 100,000 69.41 17.44 7.84 Installed 2-AB, 2-BC, 1-AC A19 Dimensions shown are representative of outside box length, width, & depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. 2-44 5th Jaw Assembly 햳 Order filler plate ECCP3U if using standard 2" wide circuit breaker (QP). 햴 NOT for use on 3 phase-4 wire delta systems. 햵 Order ECMM5IJ for insulated 5th jaw. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햶 Max. AIC determined by maximum AIC of tenant breakers. Higher ratings may be achieved thru approved series rating combinations. Discount Schedule RESI Meter Centers Modular Metering: Residential Modules—Ringless Style Selection Features WMM4200UR Four Socket Module Check local utility requirements prior to installation. 1-Phase, 3-Wire SN, Incoming & Outgoing, Ringless Type Gangable Meter Stacks 125 1200 200 Dimensions Field Installed Maximum 5th Jaw KO AIC Height Width Depth Assembly Fig. Horn Bypass Catalog Number List No Price $ Bypass List Price $ 2 WMM2UR 1492.00 WMM2URNJ 1540.00 65,000 32.41 13.44 7.84 ECMM5J A11 3 WMM3UR 1677.00 WMM3URNJ 1739.00 65,000 41.41 13.44 7.84 ECMM5J A12 4 WMM4UR 2195.00 WMM4URNJ 2330.00 65,000 50.41 13.44 7.84 ECMM5J A13 5 WMM5UR 2806.00 WMM5URNJ 2935.00 65,000 59.41 13.44 7.84 ECMM5J A14 6 WMM6UR 3427.00 WMM6URNJ 3744.00 2 WMM2200UR 3208.00 WMM22URNJ 1610.00 3 WMM3200UR 3451.00 WMM32URNJ 3574.00 HQPPH, QP, 100,000 47.41 17.44 7.84 ECMM5J A17 4 WMM4200UR 4782.00 WMM42URNJ 4878.00 QPH, HQP 100,000 58.41 17.44 7.84 ECMM5J A18 Thru-Bus Cont. Meter Rating Amps/ Positions (amps) Pos Per Stack Breaker Provision QP, QPH, HQP QPP, QPPH, HQPP, 65,000 68.41 13.44 7.84 ECMM5J A15 100,000 36.41 17.44 7.84 ECMM5J A16 3-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, 5-Jaw Ringless Type Gangable Meter Stacks Thru-Bus Cont. Meter Rating Amps/ Positions (amps) Pos Per Stack 3 4 125 5 1200 6 Horn Bypass 200 4 WMM34UR 1761.00 WMM34URNJ 1840.00 2378.00 WMM44ABURNJ 2485.00 Dimensions Breaker Maximum Provision AIC Height Width Depth QP, Stack Phasing Phases/Sockets KO Fig. 65,000 41.41 13.44 7.84 1-AB, 1-BC, 1-AC A12 65,000 50.41 13.44 7.84 2-AB, 1-BC, 1-AC A13 A14 WMM44BCUR 2378.00 WMM44BCURNJ 2485.00 QPH, 65,000 50.41 13.44 7.84 1-AB, 2-BC, 1-AC WMM44CAUR 2378.00 WMM44CAURNJ 2485.00 HQP 65,000 50.41 13.44 7.84 1-AB, 1-BC, 2-AC A14 WMM54ABUR 3029.00 WMM54ABUR3NJ 3208.00 65,000 59.41 13.44 7.84 1-AB, 2-BC, 2-AC A14 WMM54BCUR 3029.00 WMM54BCURNJ 3208.00 65,000 59.41 13.44 7.84 2-AB, 1-BC, 2-AC A15 WMM54CAUR 3029.00 WMM54CAURNJ 3208.00 65,000 59.41 13.44 7.84 2-AB, 2-BC, 1-AC A15 WMM64UR 3744.00 WMM64URNJ 3774.00 65,000 68.41 13.44 7.84 2-AB, 2-BC, 2-AC A15 3363.00 100,000 36.41 17.44 7.84 1-BC, 1-AC A16 — — WMM24AB2URNJ WMM34200UR 3649.00 WMM342URNJ 3720.00 100,000 47.41 17.44 7.84 1-AB, 1-BC, 1-AC A17 WMM44AB200UR 4657.00 WMM44AB2URNJ 4782.00 QP, QPH, 100,000 58.41 17.44 7.84 2-AB, 1-BC, 1-AC A18 WMM44BC200UR 4657.00 WMM44BC2URNJ 4782.00 HQP, QPP 100,000 58.41 17.44 7.84 1-AB, 2-BC, 1-AC A18 WMM44CA200UR 4657.00 WMM44CA2URNJ 4782.00 QPPH, 100,000 58.41 17.44 7.84 1-AB, 1-BC, 2-AC A18 5399.00 HQPP, 100,000 69.41 17.44 7.84 1-AB, 2-BC, 2-AC A19 — 5 List Price $ WMM44ABUR 2 3 Catalog Number List No Price $ Bypass WMM54AB2URNJ — — WMM54BC2URNJ 5399.00 HQPPH 100,000 69.41 17.44 7.84 2-AB, 1-BC, 2-AC A19 — — WMM54CA2URNJ 5399.00 100,000 69.41 17.44 7.84 2-AB, 2-BC, 1-AC A19 Dimensions shown are representative of outside box length, width, & depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Discount Schedule RESI — Order filler plate ECCP3U if using standard 2" wide circuit breaker (QP). NOT for use on 3 phase-4 wire delta systems. Order ECMMI5J for insulated 5th jaw. Max. AIC determined by maximum AIC of tenant breakers. Higher ratings may be achieved thru approved series rating combinations. Only “NJ” suffix should be used within the Florida Meter Group territory. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-45 METER CENTERS WMM3UR Three Socket Module ▪ Single bolt joint coupler included. Order additional couplers as needed. Use closure plates from main device to seal openings for thru bus on side. ▪ 200A units UL Listed for use on systems capable of delivering up to 100,000 RMS symmetrical amperes maximum short circuit current Series Tested Systems — Specify Siemens Modular Metering equipment in conjunction with EQ® III or Ultimate Load Centers. 2 ▪ UL Listed for 60/75°C conductors. See equipment markings for applications ▪ Individual split covers with barrel lock compatibility ▪ Available with and without factory installed horn bypass - field install horn bypass kit available (#ECHBK) ▪ Interconnectable with discontinued “MM” modular metering ▪ Factory phased 3ø units saves on installation time Meter Centers METER CENTERS 2 Modular Metering: Commercial Modules—Introduction General Commercial metering applications using 240volts, such as shopping centers, office buildings, and small commercial buildings frequently require different meter sockets from those used in residential applications. In many instances a 3-phase meter socket and tenant circuit breaker must be used. Siemens is proud to offer a complete line of commercial metering to meet the majority of the vast array of utility specifications for commercial meter services. For those utilities requiring a lever bypass Siemens has a complete line of 100-320amp/position lever bypass meter modules using the high-quality Landis & Gyr HQ lever bypass block. These modules offer several Siemens exclusive features to help installation. If a EUSERC-approved commercial service is needed Siemens is now proud to offer our line of test-block bypass (TBB) commercial meter modules. These devices eliminate the labor intensive bussed gutter solution that was used in the past. Some utilities require a bolt-in meter for 400amp applications. The bolt-in meter socket (also called K base) was designed and still originates with Landis & Gyr. Siemens offers the widest array of K base meter modules in the industry. The socket used in these modules is utility specific so please check for approval prior to installation. The versatitlity and capability of the Siemens line of commercial meter modules has been designed to fit the majority of application and utility requirements and can be inter-connected with residential meter modules for maximum versatility. Lever Bypass Siemens lever bypass meter modules are designed to stand up to the heavy demands of commercial services. Siemens features the Landis & Gyr HQ meter block at each position. Modules are available with 3-phase or single phase thru bus coupled with 3-phase or single phase tenant circuit breakers. Applications requiring 240/120V AC 3-phase 4-wire Delta should only use those modules with a 3-phase tenant main provision. Features include: ▪ 1-4 positions on 100 and 200amp devices ▪ 1-2 positions on 320amp(400amp max) devices ▪ 100,000 AIC on 200amp devices ▪ Factory installed tenant breakers on 320amp devices ▪ 3-Phase 100amp devices- saves on cost of 3-phase tenant mains ▪ 5th jaw included, standard, on all single phase meter modules ▪ 1200amp thru-bus, NEMA 3R outdoor construction ▪ Siemens exclusive floating deadfront on 200amp devices- eliminates the need for filler plates when using a 100amp breaker in a 200amp provision ▪ Centrally located neutrals and ground lugs by each breaker provision ▪ Factory phased sockets reduces installation time ▪ Horizontal 3-phase breaker mounting- reduces install time and effort Test Block Bypass Siemens line of test-block-bypass (TBB) meter modules are designed to provide a solution for commercial group metering applications in utility service areas that follow the EUSERC specification. Each position features the same meter block used on Siemens’ commercial switchboards to maintain high quality standards. Modules are available with 3-phase or single phase thru bus coupled with 3-phase or single phase tenant circuit breakers. Applications requiring 240/120V AC 3-phase 4-wire Delta should only use those modules with a 3-phase tenant main provision. Features include: ▪ 1-3 positions on 200amp devices ▪ Field conversion from 200amp to 100amp breakers with no additional kits ▪ 225 max tenant breaker capability ▪ Horizontal breaker mounting reduces install time and effort ▪ Centrally located neutral lugs K Base Siemens line of modules featuring the Landis & Gyr bolt-in meter socket (K base) is the most extensive in the industry. These modules are available in 1 position only and are available with 3-phase or single phase thru bus coupled with 3-phase or single phase tenant circuit breakers. Applications requiring 240/120V AC 3-phase 4-wire Delta should only use those modules with a 3-phase tenant main provision. These modules should not be installed until the local utility has given approval. Features include: ▪ factory installed 400amp Siemens circuit breaker ▪ 400amp continuous/400amp max Landis & Gyr K base meter socket (K7 for three phase, type K5 for single phase) 2-46 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Commercial Meter Modules: Single Phase Lever Bypass Selection Features High-quality Landis & Gyr HQ lever bypass block Ground lugs mounted by each position 225amp tenant main provisions Floating deadfront eliminates need for 100amp conversion kits or filler plates Centrally located neutral lugs 2 Compact size METER CENTERS ▪ ▪ ▪ ▪ ▪ ▪ ▪ 100,000 AIC Rating W1MM4225U Features ▪ ▪ ▪ ▪ ▪ High-quality Landis & Gyr HQ lever bypass block Factory installed 400amp tenant main breaker 225amp tenant main provisions One & Two position units now available 42,000 AIC Rating W1MM2400 1-Phase, 3-Wire SN , Incoming and Outgoing, Ringless Type Lever Bypass Gangable Meter Stacks Thru-Bus Max Tenant Rating Breaker (amps) (amps) Meter Positions Per Stack Catalog Number List Price $ Breaker Provision Dimensions Width Depth Maximum AIC Height Bypass Type KO Fig. 100,000 23.75 23.50 9.13 Lever 100,000 36.75 23.50 9.13 Lever A21 100,000 49.75 23.50 9.13 Lever A22 1-Phase 4-Jaw Sockets, 1 Phase-3 Wire Thru-Bus 120/240V AC Max. -Lever Bypass 1200 225 1 W1MM1225U 2982.00 2 W1MM2225U 6136.00 3 W1MM3225U 9194.00 QP, QPH HQP, QPP, QPPH, HQPP, HQPPH A20 4 W1MM4225U 12370.00 100,000 62.75 23.50 9.13 Lever A23 400 1 W1MM1400 8358.00 JXD22B400 Factory inst. 42,000 57.00 26.00 8.66 Lever A24 400 2 W1MM2400 12720.00 JXD22B400 Factory inst. 42,000 70.38 23.00 9.69 Lever A26 Dimensions shown are representative of box dimensions and do not include allowances for mounting bumps, hubs or hardware protrusions. Not for use on 3 phase-4 wire delta systems. Discount Schedule RESI Max. AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be acheived thru approved series rating combinations. Alternate trip amerpages available. To order, add -amperage after catalog number (350amp becomes W1MM1400-350). List price remains the same. Contact sales office for lead time. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-47 Meter Centers Commercial Meter Modules: 3-Phase Input with 1-Phase Output Lever Bypass Selection Features METER CENTERS 2 ▪ ▪ ▪ ▪ ▪ ▪ ▪ High-quality Landis & Gyr HQ lever bypass block Ground lugs mounted by each position 225amp tenant main provisions Floating deadfront eliminates need for 100amp conversion kits or filler plates Centrally located neutral lugs Compact size 100,000 AIC Rating W2MM4AB225U Features ▪ ▪ ▪ ▪ High-quality Landis & Gyr HQ lever bypass block Factory installed 400amp tenant main breaker One & Two position units now available 42,000 AIC Rating W2MM2400AB 3-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, Ringless Type Lever Bypass Gangable Meter Stacks Thru-Bus Max Tenant Rating Breaker (amps) (amps) Meter Positions Catalog Per Stack Number List Price $ Breaker Provision Dimensions Maximum AIC Height Width Depth Bypass Type Stack Phasing: Phases/Socket KO Fig. 1-Phase 5-Jaw Sockets, 3 Phase-4 Wire Thru-Bus 208Y/120V AC-Lever Bypass 1200 1 W2MM1225U 3056.00 65,000 23.75 23.50 9.13 Lever 1-AB A20 2 W2MM2AB225U 6090.00 65,000 36.75 23.50 9.13 Lever 1-AC, 1-BC A21 2 W2MM2BC225U 6090.00 65,000 36.75 23.50 9.13 Lever 1-AC, 1-AB A22 2 W2MM2CA225U 6090.00 65,000 36.75 23.50 9.13 Lever 1-AB, 1-BC A23 3 W2MM3225U 9022.00 4 W2MM4AB225U 12001.00 4 4 400 400 225 QPPH, HQPP, 100,000 49.75 23.50 9.13 Lever 1-AB, 1-BC, 1-CA A20 100,000 62.75 23.50 9.13 Lever 2-AB, 1-BC, 1-CA A21 W2MM4BC225U 12001.00 100,000 62.75 23.50 9.13 Lever 1-AB, 2-BC, 1-CA A22 W2MM4CA225U 12001.00 100,000 62.75 23.50 9.13 Lever 1-AB, 1-BC, 2-CA A23 1 W2MM1400AB 8358.00 JXD22B400 Factory inst. 42,000 57.00 26.00 8.66 Lever 1-AB A24 2 W2MM2400AB 13992.00 JXD22B400 Factory inst. 42,000 70.38 23.00 9.69 Lever 1-AB, 1-BC A26 Dimensions shown are representative of box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. Not for use on 3 phase-4 wire delta systems. Max. AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be acheived thru approved series rating combinations. 2-48 QP, QPH HQP, QPP, HQPPH Alternate trip amerpages available. To order, add -amperage after catalog number (350amp becomes W1MM1400-350). List price remains the same. Contact sales office for lead time. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Modules are factory phased. End user is responsible for balancing each phase by selecting the correct model number. Discount Schedule RESI Meter Centers Commercial Meter Modules: Three Phase with Lever Bypass Selection Features ▪ High-quality Landis & Gyr HQ lever bypass block ▪ Ground lugs mounted by each position ▪ Centrally located neutral lugs 2 ▪ Horizontal breaker mounting reduces install time and effort W3MM4200U METER CENTERS ▪ 100amp modules save on tenant main cost W3MM3 Features ▪ High-quality Landis & Gyr HQ lever bypass block ▪ 400amp tenant main breaker factory installed ▪ One & Two position units now available ▪ 42,000 AIC Rating W3MM1400 3-Phase, 4-Wire SN, Incoming and Outgoing, Ringless Type Lever Bypass Gangable Meter Stacks Thru-Bus Max Tenant Rating Breaker (amps) (amps) Meter Positions Per Stack Catalog Number List Price $ Breaker Provision Dimensions Maximum AIC Height Width Depth Bypass Type KO Fig. 65,000 29.11 20.21 8.93 Lever 65,000 44.70 20.21 8.93 Lever 3-Phase 7-Jaw Sockets, 3 Phase-4 Wire Thru-Bus 208Y/120V AC Max. -Lever Bypass 100 1 W3MM1 3352.00 2 W3MM2 6555.00 3 W3MM3 9681.00 65,000 61.20 20.21 8.93 Lever 4 W3MM4 12942.00 65,000 77.70 20.21 8.93 Lever 100,000 23.75 23.50 9.13 Lever 100,000 36.75 23.50 9.13 Lever A21 100,000 49.75 23.50 9.13 Lever A22 QP, QPH HQP 3-Phase 7-Jaw Sockets, 3 Phase-4 Wire Thru-Bus 240V AC Max. -Lever Bypass 1200 200 1 W3MM1200U 3352.00 2 W3MM2200U 6555.00 3 W3MM3200U 9681.00 QJ, QH2, QJ2-H, HQJ2-H A20 4 W3MM4200U 12942.00 100,000 62.75 23.50 9.13 Lever A23 400 1 W3MM1400 8358.00 JXD22B400 Factory inst. 42,000 57.00 26.00 8.56 Lever A24 400 2 W3MM2400 15370.00 JXD22B400 Factory inst. 42,000 70.38 23.00 9.69 Lever A26 Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. Accepts 3-pole 100amp maximum circuit breaker. Discount Schedule RESI Max. AIC determined by maximum AIC of tenant breakers used in conjunction with meter socket. Higher ratings may be acheived overall thru approved series rating combinations. Alternate trip amerpages available. To order, add -amperage after catalog number (350amp becomes W3MM1400-350). List price remains the same. 1 high units only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-49 Meter Centers Commercial Meter Modules: K Base Bolt-In Meter Modules Selection Features ▪ All modules feature the Landis & Gyr K5 (single phase) or K7 (three phase) Bolt-on Meter Base METER CENTERS 2 ▪ 22,000 AIC Rating Note: Users are advised to contact utility PRIOR to installation to verify approval. User assumes all responsibility for ensuring utility acceptance prior to installation. 1-Phase, 3-Wire SN, Incoming and Outgoing, Ringless Type Lever Bypass Gangable Meter Stacks Thru-Bus Max Tenant Meter Rating Breaker Positions Catalog List Maximum Dimensions (amps) (amps) Per Stack Number Price $ Breaker Provision AIC Height Width 1-Phase 5 Terminal Landis & Gyr K5 Bolt-In Socket, 1 Phase-3 Wire Thru-Bus 120/240V AC Max.-No Bypass Depth Stack Phasing: Phases/Socket KO Fig. 1200 8.66 — A25 400 1 W1MM1400B 10029.00 JXD22B400 Factory inst. 22,000 47.94 29.83 3-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, Ringless Type Lever Bypass Gangable Meter Stacks Thru-Bus Max Tenant Rating Breaker (amps) (amps) Meter Positions Per Stack Catalog Number List Price $ Breaker Provision Maximum AIC Dimensions Height Width Depth Stack Phasing: Phases/Socket KO Fig. 29.83 8.66 1-AB A25 1-Phase 5 Terminal Landis & Gyr K5 Bolt-In Socket, 1 Phase-3 Wire Thru-Bus 120/240V AC Max.-No Bypass 1200 400 1 W2MM1400BAB 10029.00 JXD22B400 Factory inst. 22,000 47.94 3-Phase, 4-Wire SN, Incoming and Outgoing, Ringless Type Lever Bypass Gangable Meter Stacks Thru-Bus Max Tenant Meter Rating Breaker Positions Catalog List Maximum Dimensions (amps) (amps) Per Stack Number Price $ Breaker Provision AIC Height Width 3-Phase 7 Terminal Landis & Gyr K7 Bolt-In Socket, 3 Phase-4 Wire Thru-Bus 240V AC Max.-No Bypass 1200 400 1 W3MM1400B Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. Not for use on 3 phase-4 wire delta systems. Maximum AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher ratings may be acheived thru approved series rating combinations. 2-50 10029.00 JXD22B400 Factory inst. 22,000 47.94 29.83 Depth Stack Phasing: Phases/Socket KO Fig. 8.66 — A25 Alternate trip amerpages available. To order, add -amperage after catalog number (350amp becomes W3MM1400-350). List price remains the same. Lead time applies. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers Modular Metering: Commercial Modules—Test Block Bypass Selection Features ▪ EUSERC Compliant Test Block Bypass ▪ Ground lugs mounted by each position ▪ 225amp tenant breaker privisions (breakers not included) 2 ▪ Single phase modules available with three phase thru bussing ▪ Floating deadfront eliminates need for 100amp conversion kits or filler plates Thru-Bus Maximum Socket Meter Rating Tenant Continuous Positions Catalog (Amps) Breaker Duty Amps Per Stack Number List Price $ 1-Phase, 3-Wire Feed & Tenant Mains 120/240V AC Max.햲 1200 225 200 1 W1MM1225USS 1468.00 1200 225 200 2 W1MM2225USS 2823.00 1200 225 200 3 W1MM3225USS 4215.00 3-Phase, 4-Wire Feed & 1-Phase, 3-Wire Tenant Mains 120Y/208V AC Max.햲 1200 225 200 1 W2MM1225USS 1609.00 1200 225 200 2 W2MM2AB225USS 2964.00 1200 225 200 2 W2MM2BC225USS 2964.00 1200 225 200 2 W2MM2CA225USS 2964.00 1200 225 200 3 W2MM3225USS 4356.00 3-Phase, 4-Wire Feed & Tenant Mains 240V Max.햳 1200 225 200 1 W3MM1225USS 1779.00 1200 225 200 2 W3MM2225USS 3344.00 1200 225 200 3 W3MM3225USS 4949.00 햲 햳 햴 Breaker Provisions 햴 Max. AIC Dimensions (inches) Stack Phasing Phases/Socket H W D QP, QPH, HQP, QPP, QPPH, HQPP, HQPPH 100,000 26.5 100,000 46.0 100,000 65.5 25.5 25.5 25.5 9.0 9.0 9.0 — — — QP, QPH, HQP, QPP, QPPH, HQPP, HQPPH 100,000 100,000 100,000 100,000 100,000 26.5 46.0 46.0 46.0 65.5 25.5 25.5 25.5 25.5 25.5 9.0 9.0 9.0 9.0 9.0 1-AB 1-AC, 1-AC, 1-AB, 1-AB, QJ, QJH2, QJ2H, HQJ2H 100,000 26.5 100,000 46.0 100,000 65.5 25.5 25.5 25.5 9.0 9.0 9.0 — — — KO Fig. A27 A28 A29 1-BC 1-AB 1-BC 1-BC, 1-AC A27 A28 A28 A28 A29 A27 A28 A29 Not rated for use with 240/120V Delta systems. Rated for use with 240/120V Delta systems. Stacks will accept equivalent Murray circuit breakers. Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-51 METER CENTERS ▪ Horizontal breaker mounting reduces install time and effort Meter Centers Modular Metering: Residential Modules햲 Knockout Diagrams Residential Meter Modules — 125A, 200A - 2 Gang Wiring Diagrams Catalog Number 햳 METER CENTERS 2 WMM2U WMM2200U Knockout Diagrams A11 햲 A16 Catalog Number Catalog Number WMM2U WMM2200U WMM24AB200U WMM24BC200U WMM24CA200U Diagrams also applicable for suffix R, RC and RNJ products. 2-52 햳 Diagrams also applicable for 200A product. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Residential Modules ▪ 2-high modules — suffix indicates phases not used Wiring Diagrams / Knockout Diagrams ▪ 4-high modules — suffix indicates phase with two sockets ▪ 5-high modules — suffix indicates phase with one socket in the module Wiring Diagrams Catalog Number WMM3U WMM3200U WMM34U 2 Catalog Number METER CENTERS Knockout Diagrams A12 A17 Catalog Number Catalog Number WMM3U WMM34U WMM3200U WMM34200U Diagrams also applicable for suffix R, RC and RNJ products. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-53 Meter Centers Modular Metering: Residential Modules햲 ▪ 2-high modules — suffix indicates phases not used Wiring Diagrams / Knockout Diagrams ▪ 4-high modules — suffix indicates phase with two sockets ▪ 5-high modules — suffix indicates phase with one socket in the module Wiring Diagrams Catalog Number Catalog Number Catalog Number Catalog Number WMM44ABU WMM44BCU WMM44CAU METER CENTERS 2 WMM4U WMM4200U A17 Knockout Diagrams A13 햲 A18 Catalog Number Catalog Number WMM4U WMM44ABU WMM44BCU WMM44CAU WMM4200U WMM44AB200U WMM44BC200U WMM44CA200U Diagrams also applicable for suffix R, RC and RNJ products. 2-54 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Residential Modules햲 ▪ 2-high modules — suffix indicates phases not used Wiring Diagrams / Knockout Diagrams ▪ 4-high modules — suffix indicates phase with two sockets ▪ 5-high modules — suffix indicates phase with one socket in the module Wiring Diagrams Catalog Number Catalog Number Catalog Number Catalog Number WMM5U WMM54ABU WMM54BCU WMM54CAU 2 METER CENTERS Knockout Diagrams A19 A14 Catalog Number WMM54AB200U WMM54BC200U WMM54CA200U Catalog Number WMM5U WMM54ABU WMM54BCU WMM54CAU For inches / millimeters conversion, see Application Data section. 햲 Diagrams also applicable for suffix R, RC and RNJ products. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-55 Meter Centers Modular Metering: Residential Modules Outdoor Knockout Diagrams Catalog Number WMM64U WMM6U A15 Catalog Number WMM6U WMM64U For inches / millimeters conversion, see Application Data section. 2-56 ▪ 2-high modules — suffix indicates phases not used ▪ 4-high modules — suffix indicates phase with two sockets ▪ 5-high modules — suffix indicates phase with one socket in the module Catalog Number METER CENTERS 2 3-Phase, 4-Wire, Incoming / 1-Phase, 3-Wire, Outgoing All 3-phase 4-wire meter modules have the maximum possible degree of phase balancing. Wiring Diagrams Wiring Diagrams / Knockout Diagrams Single phase sockets are factory- connected to different phases for automatic load balancing. Do not use single stator network meters. Note: Diagrams also applicable for suffix R, RC and RNJ product. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Main Switch Service Entrance Modules Knockout Diagrams Installation Dimensions No knockouts on sides of any modules. 2 METER CENTERS A1A Catalog Number WMS4U WMS44U A1B Catalog Number WMS6U WMS64U For inches / millimeters conversion, see Application Data section. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-57 Meter Centers METER CENTERS 2 Service Entrance Modules - Main Switch A1C Catalog Number WMS8U WMS84U T Fuse Provision A1D Catalog Number WMS12U WMS124U Molded Case Switch, ND63S120A For inches / millimeters conversion, see Application Data section. 2-58 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Knockout Diagrams Meter Centers Modular Metering: Tap Box & Main Switch Modules A2 Knockout Diagrams A3 Catalog Number Catalog Number WMTB8U WMTB84U WMP02U WMP024U 2 METER CENTERS A2A Catalog Number WMS4UPBU WMS44UPBU WMS6UPBU WMS64UPBU WMS8UPBU WMS84UPBU For inches / millimeters conversion, see Application Data section. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-59 Meter Centers Service Entrance Modules - Main Circuit Breaker METER CENTERS 2 Knockout Diagrams A4A A4B Catalog Number Catalog Number WMC4 WMC44 WMC4BF WMC44BF A4C A4D Catalog Number Catalog Number WMC6 WMC64 WMC6BF WMC64BF For inches / millimeters conversion, see Application Data section. 2-60 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Main Breaker Modules Knockout Diagrams A6A Catalog Number 2 WMC10 WMC12 WMC104 WMC124 METER CENTERS A5A Catalog Number WMC7 WMC74 WMC8 WMC84 A6B Catalog Number WMC10BF WMC12BF WMC104BF WMC124BF A5B Catalog Number WMC7BF WMC74BF WMC8BF WMC84BF For inches / millimeters conversion, see Application Data section. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-61 Meter Centers Knockout Diagrams METER CENTERS 2 Modular Metering: Main Breaker & Tap Box Modules A7A A8 A7B Catalog Number Catalog Number WMC14 WMC144 WMC16 WMC164 WMC14BF WMC144BF WMC16BF WMC164BF A9 Catalog Number Catalog Number WMTB12U WMTB124U WMTB16U WMTB164U For inches / millimeters conversion, see Application Data section. 2-62 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Pullbox & Lever Bypass Modules A10A A10B Knockout Diagrams A10C Catalog Number Catalog Number Catalog Number WMMB1400 WMMB3400 WMMB1800 WMMB3800 WMMB11200 WMMB31200 2 METER CENTERS A30A A30B Catalog Number Catalog Number MC20 MC20BF For inches / millimeters conversion, see Application Data section. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-63 Meter Centers Modular Metering: Lever Bypass Modules Knockout Diagrams For Lever Bypass Modules Only A20 A21 Catalog Number WXMM1XXXX WXMM2XXXX METER CENTERS 2 Catalog Number For Lever Bypass Modules Only A22 A23 Catalog Number Catalog Number WXMM3XXXX WXMM4XXXX For inches / millimeters conversion, see Application Data section. 2-64 햲 See table on page 2-49 for 3-Phase 100A stack dimensions. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Lever Bypass Modules Wiring Diagrams Commercial Meter Modules, Specifications With 5-Jaw, 1-Phase, 3-Wire Outgoing Landis & Gyr Meter Sockets 1-Phase Incoming & Outgoing 3-Phase Incoming & Outgoing 2 Wiring Diagram References As Shown All 3 High Omit Top Meter All 2 High Omit Top Two Meters All 1 High Omit Top Two and Bottom Meters METER CENTERS Meter Module Configuration All 4 High Catalog Number Catalog Number Catalog Number Catalog Number W2MM1225U W2MM2AB225U W2MM2BC225U W2MM2CA225U Catalog Number Catalog Number Catalog Number Catalog Number W2MM3225U W2MM4AB225U W2MM4BC225U W2MM4CA225U Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-65 Meter Centers Modular Metering: Lever Bypass Modules Wiring and Knockout Diagrams Provision for HV Type Hubs A24 A25 METER CENTERS 2 Provision for Type HD Hubs Catalog Number Catalog Number W1MM1400 W2MM1400AB W3MM1400 W1MM1400B W2MM1400BAB W3MM1400B A26 Catalog Number WXMM2400 For inches / millimeters conversion, see Application Data section. 2-66 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Test Block Bypass Modules A27 Wiring and Knockout Diagrams A29 2 METER CENTERS A28 Note: KO diagrams apply to test block bypass modules only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-67 Meter Centers Commercial Meter Modules Wiring and Knockout Diagrams Wiring Diagrams for 400A Plug-in and Bolt-in Socket EQUIPMENT GROUND B N METER CENTERS 2 A A N B C W1MM1400 A N B C W2MM1400 W3MM1400 W1MM1225USS W1MM2225USS W1MM3225USS 2-68 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Meter Centers Modular Metering: Test Block Bypass Modules Wiring and Knockout Diagrams A N B C A N B C 2 NEUTRAL LUGS EQUIPMENT GROUND L I N E L O A D L I N E METER CENTERS NEUTRAL (POTENTIAL JAW) L O A D W2MM1225USS W2MM2AB225USS W2MM2BC225USS W2MM2CA225USS W2MM3225USS W3MM1225USS W3MM2225USS W3MM3225USS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-69 Meter Centers Uni-Pak Metering: Technical Information METER CENTERS 2 Selection Four-position All-in-One featuring angled breaker design. Four-position lever bypass All-in-One. General Information Design/Performance Features Siemens’ all new Uni-Pak Metering offers maximum flexibility and ease of installation to meet the service requirements of multiple position metering projects. The outdoor/indoor devices are available in two through six gang set-ups which consist of a pull section with main lugs or stud terminations, and 4/5 jaw meter sockets with tenant circuit breaker provisions. ▪ Siemens’ exclusive 200 ampere/position non-lever bypass units feature angled breaker for faster & easier installations ▪ New Siemens’ exclusive floating deadfront on 200 ampere devices eliminates need to line up breakers & covers ▪ UL Listed for Service Equipment ▪ UL Listed for use with 60/75°C wire ▪ UL Listed for short circuit ratings up to 100,000 RMS symmetrical amps at 240V AC ▪ Outdoor/indoor construction ▪ Overhead or underground service; load top, bottom or back ▪ Front accessible 4 or 5-jaw sockets with individual ring or ringless type meter covers ▪ 125 amp sockets feed plug-in tenant breakers through 125 amperes ▪ 200 amp sockets feed plug-in tenant breakers through 200 amps ▪ All unmetered bus is barriered and sealable to prevent unauthorized access ▪ Compact wall-hung design for ease of handling and installation ▪ Fifth jaw field installable at 3 or 9 o’clock ▪ NEW Lever Bypass now available The units operate on 120/240V AC 1ø3W systems and are available with either 125 or 200 ampere meter sockets to meet a wide variety of small apartment and commercial building applications. A fifth jaw accessory kit is available for use on 120/208YV AC 1ø3W network systems. The attractive Uni-Pak devices accept overhead or underground service terminations and are designed for wallhung surface or semi-flush mounting. The devices are factory pre-bussed in a compact enclosure to ensure ease of handling and installation and to maximize wall-space efficiency. In addition to local code and National Electrical Code requirements, the serving utility may have special requirements for metering devices. Confirm utility acceptance prior to order placement. Three meter position All-In-One. ▪ Electrodeposited paint provides uniform coverage for long-lasting protection and sharp appearance ▪ Meets EUSERC specifications when NEMA stud kit and flange kit (if required) are field-added (not available for lever bypass versions) Technical Information Uni-Pak devices are UL listed under file #E27100 as service entrance equipment. Complete Selection Number of Meter Jaws Voltage Amperes (per Meter position) Amperes (Bus) Tenant Main Breakers Number of Meter Positions Service 4 or 5 240V AC Maximum 125 amp or 200 amp Maximum 800 amps Maximum Provisions for plug-in tenant circuit breakers through 200A 2, 3, 4, 5 or 6 Overhead or underground with load top, bottom or back Industry Specifications All-In-One residential group metering units comply with the following industry standards. ANSI — Standard #C 12.7-1987 NEMA — Standard #250-1985 UL — File #E27100 UL — Standard #50, 67, 414 Catalog Number Logic SP6511RJL Siemens Uni-Pak Metering 8 6 5 4 3 2 0 2-70 = = = = = = = Bus Rating 800 Amp 600 Amp 500 Amp 400 Amp 300 Amp 200 Amp no bussing # of Positions 6 = 6 position 5 = 5 position 4 = 4 position 3 = 3 position 2 = 2 position Phase 1 = 1-Phase SKT Rating 1 = 125 Amp max 2 = 200 Amp max Cover Type blank = ring type R = ringless Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog # of Jaws blank = 4-Jaw J = 5-Jaw Bypass Type blank = no bypass B = horn bypass L = lever bypass Meter Centers Uni-Pak Metering: Selection-Ring Style Selection Floating deadfront! eliminates need for cover alignment Smaller, more compact design! enclosures are lighter and use less wall space Angled circuit breaker for ease of installation! ▪ ▪ ▪ ▪ ▪ Stud Kits for line compression lugs available Centrally located neutral minimizes neutral conductor length More secure design! greater utility acceptance ▪ Barriered, sealable compartment for unmetered current-carrying parts ▪ Al/Cu lay-in lugs, except two socket units ▪ Top or bottom feed ▪ Bottom and rear branch wiring exits (Neutral and ground at bottom only) ▪ ANSI #61 light gray electrodeposited paint on zinc-coated G90 steel ▪ Meets EUSERC specifications when NEMA stud kit and flushing ring (if required) is field added Back and Bottom Exit for load conductors Meets EUSERC requirements when stud kit is installed Single-piece tenant cover! easy installation SP6512 1-Phase, 3-Wire SN, Ring Type, Uni-Pak Meter Center Continuous Meter Duty Amps Bus Positions Catalog Breaker Maximum Per Position Amperage Per Pak Number Provision AIC Dimensions 햲 Height Width Depth 5th Jaw Assembly Line Lugs Wire Range List Price $ 1-Phase, 4-Jaw Sockets, 120/240V AC Max. 125 200 200 300 400 2 3 4 SP2211 SP3311 SP4411 400 400 500 600 600 400 400 400 600 600 600 800 5 6 4 5 6 2 3 4 4 5 6 6 SP4511 SP4611 SP5411 SP6511 SP6611 SP4212 SP4312 SP4412 SP6412 SP6512 SP6612 SP8612 햳 QP QPH HQP QP QPH HQP QPP QPPH HQPP HQPPH 65,000 65,000 65,000 37.63 38.40 47.40 13.67 25.50 25.50 6.00 7.50 7.50 ECMM5J ECMM5J ECMM5J #6-300 kcmil #6-300 kcmil 1/0-750 MCM CU-AL 1242.00 1494.00 2122.00 65,000 65,000 65,000 65,000 65,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 38.40 38.40 47.40 38.40 38.40 31.50 38.44 47.44 47.44 38.44 38.44 38.44 39.20 39.20 31.50 45.20 45.20 29.50 29.50 29.50 35.50 53.10 53.10 53.10 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J ECMM5J or (2) 1/0-250 AL or (2) 1/0-3/0 CU 2686.00 3113.00 2636.00 (2) #2-600 kcmil 3038.00 3640.00 1749.00 2587.00 3392.00 3740.00 1/0-750 MCM CU-AL or (2) 1/0-250 AL or (2) 1/0-3/0 CU (2) #2-600 kcmil Flushing Rail Kits: 4371.00 5127.00 5625.00 Description List Price $ 125 Amps per position SP221FK SP331FK SP441FK SP4561FK SP6561FK 2 Gang 200 amp bus 3 Gang 300 amp bus 4 Gang 400 amp bus 5&6 Gang 400 amp bus 5&6 Gang 600 amp bus 124.00 145.00 145.00 145.00 145.00 200 Amps per position 햲 Dimensions shown are representative of outside box length, width, & depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. 햳 Order NSK600 and PLK600 kits for use with SP8612. CU Cable only approved with 800A device. Discount Schedule RESI SP422FK SP432FK SP442FK SP642FK SP6562FK 2 Gang 400 amp bus 3 Gang 400 amp bus 4 Gang 400 amp bus 4 Gang 600 amp bus 5&6 Gang 600 amp bus Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 145.00 145.00 145.00 145.00 145.00 2-71 METER CENTERS Double barrel connectors available for parallel feed. ▪ ▪ Individual split covers UL Listed for 60 / 75°C conductors. See equipment markings for applications For small apartment buildings, small professional and commercial buildings Completely self-contained meter centers Two to six 125A and 200A sockets breaker positions Outdoor surface mounted enclosures Compact, pre-bussed, easy to handle, hang and wire 2 Dead front knockouts makes 200amp to 100amp conversions easy Features Meter Centers Uni-Pak Metering: Selection-Ringless Style햴 Floating deadfront! eliminates need for cover alignment METER CENTERS 2 Smaller, more compact design! enclosures are lighter and use less wall space Selection Features ▪ ▪ ▪ Factory options! 5th jaw and horn bypass Dead front knockouts makes 200amp to 100amp conversions easy Double barrel connectors available for parallel feed. Angled circuit breaker for ease of installation! ▪ ▪ ▪ ▪ Stud Kits for line compression lugs available Centrally located neutral minimizes neutral conductor length More secure design! greater utility acceptance Ringless meter construction Individual split covers with barrel lock compatibility Available with horn bypass factory installed UL Listed for 60/75° C conductors See equipment markings for applications For small apartment buildings, small professional and commercial buildings Completely self-contained meter centers Two to six 125A and 200A sockets breaker positions ▪ Compact, pre-bussed, easy to handle, hang and wire ▪ Barriered, sealable compartment for unmetered current-carrying parts ▪ AI/Cu lay-in lugs, except two socket units ▪ Top or bottom feed ▪ Bottom and rear branch wiring exits (Neutral and ground at bottom only) ▪ ANSI #61 light grey electrodeposited paint on zinc-coated steel ▪ 5th jaw kit included with each unit Back and Bottom Exit for load conductors Single-piece tenant cover! easy installation SP3311RJ 1-Phase, 3-Wire SN, Ringless Type, Uni-Pak Meter Center - No Bypass & Horn Bypass Continuous Meter Duty Amps Bus Positions Catalog Per Position Amperage Per Pak Number 햲 Breaker Maximum Dimensions Provision AIC Height Width Depth Horn Bypass Kit 5th Jaw Assembly 햳 Line Lugs Wire Range List Price $ 1-Phase, 5-Jaw Sockets, 120/240V AC Max. 125 200 햲 200 200 300 300 400 400 400 400 400 400 600 600 600 600 400 400 400 400 400 400 600 600 600 600 800 2 2 3 3 4 4 5 5 6 6 5 5 6 6 2 2 3 3 4 4 5 5 6 6 6 SP2211RJ SP2211RJB SP3311RJ SP3311RJB SP4411RJ SP4411RJB SP4511RJ SP4511RJB SP4611RJ SP4611RJB SP6511RJ SP6511RJB SP6611RJ SP6611RJB SP4212RJ SP4212RJB SP4312RJ SP4312RJB SP4412RJ SP4412RJB SP6512RJ SP6512RJB SP6612RJ SP6612RJB SP8612RJ햴 65,000 65,000 65,000 MP2211RJ 65,000 65,000 65,000 QP 65,000 QPH 65,000 HQP 65,000 65,000 65,000 65,000 65,000 65,000 100,000 100,000 QP 100,000 QPH 100,000 HQP 100,000 QPP 100,000 QPPH 100,000 HQPP 100,000 HQPPH 100,000 100,000 100,000 Dimensions shown are representative of outside box length, width, & depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. 2-72 햳 37.50 37.50 37.50 37.50 37.50 37.50 37.50 37.50 37.50 37.50 37.50 37.50 37.50 37.50 31.50 31.50 38.44 38.44 47.44 47.44 38.44 38.44 38.44 38.44 38.44 13.50 13.50 25.50 25.50 25.50 25.50 39.20 39.20 39.20 39.20 45.20 45.20 45.20 45.20 29.50 29.50 29.50 29.50 29.50 29.50 53.10 53.10 53.10 53.10 53.10 6.00 6.00 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Included Order ECMMI5J for insulated 5th jaw. Fifth terminal for RJ devices is included, but not installed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK Installed ECHBK 햴 #6-300 kcmil #6-300 kcmil #2-600 kcmil #2-600 kcmil 1/0-750 MCM CU-AL or (2) 1/0-250 AL or (2) 1/0-3/0 CU (2) #2-600 kcmil 1/0-750 MCM CU-AL or (2) 1/0-250 AL or (2) 1/0-3/0 CU (2) #2-600 kcmil 1342.00 1341.00 1673.00 1597.00 2348.00 2348.00 2938.00 2938.00 3442.00 3292.00 3340.00 3340.00 3947.00 3793.00 1875.00 1822.00 2763.00 2686.00 3589.00 3467.00 4497.00 4371.00 5300.00 5125.00 5625.00 Order NSK600 and PLK600 kits for use with SP8612RJ. CU Cable only approved with 800A device. Discount Schedule RESI Meter Centers Uni-Pak Metering: Ringless Style with Lever Bypass Selection Factory installed 5th jaw Dual hub provisions up to 4" Siemens exclusive floating deadfront High quality Landis & Gyr HQ Lever Bypass 3/8" studs on line connectionsҀ choose 1, 2, 3 conductor lug kits Centrally located neutrals Side mounted handles for easy lifting 225 amp tenant breakers Insulating barrier provides additional safety 100K AIC rated Rated for Siemens or Murray breakers Note: KO diagrams located on page 2-80. Inline column construction for 2Ҁ4 position. 5Ҁ6 position available. Mounting rail included for easy installation Barrel lock provisions for greater utility acceptance Continuous Maximum Meter Duty Amps Tenant Bus Positions Catalog 햴 Per Position Breaker Amperage Per Pak Number List Price $ Breaker Provision Maximum Dimensions (inches) 햲 AIC Height Width Depth 5th Jaw @ 9:00 Line Lugs 햳 1-Phase 5-Jaw sockets, 120/240V AC Max. 400 200 225 600 햲 2 SP4212RJL 3074.00 QP, QPH, HQP, 100,000 36.75 35.90 9.00 Installed 3/8" 3 SP4312RJL 4611.00 QPP, QPPH, 100,000 49.75 35.90 9.00 Installed Stud 4 SP4412RJL 6148.00 HQPP, HQPPH 100,000 62.75 35.90 9.00 Installed Field 5 SP6512RJL 7685.00 100,000 49.75 57.68 9.00 Installed Installed 6 SP6612RJL 9063.00 100,000 49.75 57.68 9.00 Installed Lugs Dimensions shown are representative of outside box length,width, and depth and do not include allowances for mounting bumps, endwalls, covers, hubs, or hardware protrusions. 햳 Line lugs are not included. Please order lugs from chart below. 햴 A barrel lock provision is included with each metered position. Hub Kits Lug Kits Lug Catalog Number H56476 Wire Range 3/0-800/94 kcmil H60162 (2) 1/0-250 kcmil OR List Price $ 44.00 44.00 (1) #4-600 kcmil H68752-1 (3) #6-250 kcmil 74.00 H56732-2 (2) #4-350 kcmil 35.00 H56732-M (2) #4-500 kcmil 56.00 Size (inches) Catalog Number List Price $ 2 EC56854 178.92 2.5 EC56855 178.92 3 EC56856 178.92 3.5 EC56857 263.06 4 EC56858 119.28 Closure Plate EC56933S 76.68 Note: Lug kits should be chosen based on the wire size being run to the unit. Wire should be sized according to the National Electrical Code. A total of 3 lugs are required to wire the line side of the device. Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-73 METER CENTERS Independent ground lugs 2 Generous wiring spaceҀeasy access connections The newly designed line of PAK metering from Siemens is now available for those utilities that require a lever bypass for residential & commercial applications. PAK Metering provides an all-in-one solution for applications needing from 2 – 6 meter positions. The products are designed for easy installation and include features not found on competitors, including: ▪ Side mounted handles to help in lifting ▪ “Floating” deadfront to help breaker alignment ▪ Provisions for one, two, or three incoming conductors per phase and neutral ▪ Hanging bracket to suspend the unit during installation ▪ 225 amp branch tenant provisions @ 100,000 AIC ▪ Full line of 2– 6 position devices ▪ “In-line” (column) construction for 2 – 4 position devices Siemens PAK metering has passed rigorous testing and has been accepted by many of those utilities that require a lever bypass. Meter Centers Uni-Pak Metering: Accessories METER CENTERS 2 Selection ECHS125 NSK400 SUK350TA Accessories for All-In-One Units Catalog Number Description List Price $ 5th Jaw Kit 햲 ECMM5J ECMMI5J 23.50 20.50 Bypass Kits햲 Horn Bypass Kit ECHBK 149.00 Ring Style햲 Ringless Style ECPP ECP3 19.00 19.00 Sealing Rings Snap-On Type Aluminum Screw Type Stainless Steel햴 SRSS SRSW 19.38 25.03 Filler Plates 1" Filler Plate 4" to 2" Filler Plate ECQF3 ECCP3U햲 14.20 14.20 SUK350TA SUK600TA 54.00 49.00 (2) #500-1000 kcmil SUK1000TA 64.00 Alternate Lug Kits햲 PLK400 PLK600 183.00 183.00 2" Conduit Hub햵 21⁄2" Conduit Hub햵 EC56854 EC56855 178.92 178.92 3" Conduit Hub EC56856 178.92 31⁄2" Conduit Hub EC56857 263.06 4" Conduit Hub EC56858 119.28 Closure Plate EC56933S Type “HD” Conduit Hubs 400 Amp Bus NEMA Stud Kit 600 Amp Bus NEMA Stud Kit 햳 NSK400 NSK600 Not for use on lever bypass units. Order NSK600 and PLK600 kits for use with 800 Amp PAK. CU Cable only approved with 800A device. 2-74 157.00 207.00 햴 햵 76.68 Type “RX” Conduit Hubs ⁄4" Conduit Hub 1" Conduit Hub 11⁄4" Conduit Hub 11⁄2" Conduit Hub 2" Conduit Hub 21⁄2" Conduit Hub Closure Plate Adapter plate for HD/RX햴 3 NEMA Stud Kits (Meets EUSERC Requirements)햲 햳 List Price $ (2) #6-350 kcmil (1) #2-600 kcmil 400 Amp Bus Lug Kit (2) #4-250 600 Amp Bus Lug Kit (3) #6-250 Cover Plate 햲 Catalog Number Lugs for NEMA Stud Kits햲 Grounded Insulated All Types Description EC38594 EC38596 EC38597 EC38598 EC38599 EC38600 EC38595 EC9747-1113 022.90 37.81 37.81 23.96 23.96 107.57 38.34 27.00 Use Adapter plate with RX hubs for PAK units. These items made of Adapter plate and equivalent RX hub. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers Uni-Pak Metering Wiring Diagrams NAB AB 2 METER CENTERS AB Equip. Grd. N 2 position 200 Amp 2 position 125 Amp AB AB NAB NAB AB AB AB AB AB Equip. Grd. Equip. Grd. N 3 position 125 & 200 Amp 4 position 125 & 200 Amp AB NAB AB AB AB AB AB AB AB Equip. Grd. N NAB AB AB Equip. Grd. N 5 position 125 & 200 Amp AB N N 6 position 125 & 200 Amp Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-75 Meter Centers Uni-Pak Metering METER CENTERS 2 Wiring, Dimensional & Knockout Diagrams 4 9⁄64" 16 15/16 5 5/8 2 13⁄16" 6 2 13/16 (1) Removable Hub Plate Covering HD Type Hub Opening ( Max. 4" Conduit) (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) 13 1⁄2" 8 13⁄32" 5 3⁄32" 25 1/2 4 ⁄ 1 8" 9" 9 37 1⁄2" 38 7/16 9 (2) K.O.'s for 0.50" 0.75", 1", 1.25", 1.5" 2", 2.5" Conduit 18 1⁄2" 21 1/2 17 3/4 11 1⁄4" 12 13/16 14 3 3⁄4" 8 5⁄8" 5 2 3⁄4" 2 1/4 2 17⁄32" (1) K.O.'s for 1", 1.25", 1.5", 2", 2.5", 3" Conduit 5 3⁄4" 3 7⁄16" 6 ⁄ 1 23⁄32" 3 4" (2) K.O.'s for 0.50" Conduit 2 3⁄8" (2) 0.312" DIA K.O.'s (1) K.O. for 0.50", 0.75", 1", 1.25", 1.5" Conduit (2) K.O.'s for 0.50", 0.75", 1", 1.25", 1.5", 2" Conduit 3⁄4" 7 1/2 11/16 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 5 1/2 3 3/16TYP (2).312"DiaK.O.'s 13 13/16 17 3/32 SP2211X SP3311X 2-76 5 1/8 2 3/8 1 13/16 2 7/8 1 ⁄ 1 13⁄16" 3 21⁄32" 23 3/4 6 7/16 1 16" 1 9⁄16" 10 7⁄32" 4 1⁄16" 1 1⁄2" 1 11⁄16" (1) K.O. for .5", .75", 1" Conduit (6) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (6) K.O. for .50", .75'", 6 19/32 1", 1.25", 1.5", 2", 2.5", 3" Conduit Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3 13/32 Meter Centers Uni-Pak Metering Wiring, Dimensional & Knockout Diagrams 20 15/16 5 5/8 20 15/16 5 5/8 2 13/16 2 13/16 2 (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) 29 1/2 29 1/2 METER CENTERS 9 9 31 1/2 38 7/16 9 21 1/2 17 3/4 21 1/2 12 3/4 14 17 3/4 12 3/4 14 5 19/32 2 15/32 (1) K.O. for .5", .75", 1" Conduit 7 1/2 5 19/32 2 15/32 (5) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (5) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit 27 3/4 (5) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (1) K.O. for .5", .75", 1" Conduit (5) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit 27 3/4 7 1/2 6 7/16 5 3/16 11/16 2 7/8 3 3/16TYP (2) .312" Dia K.O.'s 5 1/2 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 6 7/16 2 1/16 17 13/16 21 3/32 2 7/8 4 3/4 2 1/16 3 3/16TYP (2) .312" Dia K.O.'s 5 1/2 2", 2.5", 3", 3.5", 4' KO's with provisions (Max. 4" Conduit) 2 7/8 4 3/4 17 13/16 21 3/32 SP4312R/RJ/RJB SP4212R/RJ/RJB 20 15/16 5 5/8 16 15/16 5 5/8 5 3/16 11/16 2 7/8 2 13/16 2 13/16 (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) 29 1/2 25 1/2 9 9 9 9 47 7/16 47 7/16 30 1/2 9 26 3/4 9 30 1/2 23 26 3/4 23 12 3/4 12 3/4 5 (1) K.O. for .5", .75", 1" Conduit 7 1/2 23 3/4 2 1/4 (6) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (6) K.O. for .50", .75'", 6 19/32 1", 1.25", 1.5", 2", 2.5", 3" Conduit 6 7/16 2 7/8 5 1/8 2 3/8 1 13/16 11/16 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 5 1/2 3 3/16TYP (2).312"DiaK.O.'s 13 13/16 17 3/32 SP4411X 5 19/32 2 15/32 (5) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (1) K.O. for .5", .75", 1" Conduit (5) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit 27 3/4 7 1/2 6 7/16 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 5 3/16 11/16 2 7/8 3 13/32 5 1/2 2 1/16 3 3/16TYP (2) .312" Dia K.O.'s 2 7/8 4 3/4 17 13/16 21 3/32 SP4412R/RJ/RJB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-77 Meter Centers Uni-Pak Metering Wiring, Dimensional & Knockout Diagrams 2 13/16 (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) 2 16 3/4 5 5/8 16 15/16 5 5/8 2 13/16 39 3/16 METER CENTERS 39 3/16 9 9 38 7/16 38 7/16 9 17 3/4 9 17 3/4 21 1/2 12 3/4 14 (1) K.O. for .5", .75", 1" Conduit 5 2 1/4 (12) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (12) K.O. for .50", .75'", 6 19/32 1", 1.25", 1.5", 2", 2.5", 3" Conduit 23 3/4 6 19/32 5 1/8 3 3/16TYP 2 7/8 3 13/32 3 3/16TYP (2).312"DiaK.O.'s 13 13/16 17 3/32 5 1/2 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 23 3/4 6 7/16 7 1/2 5 1/8 2 3/8 1 13/16 11/16 1 13/16 1 13/16 3 13/32 3 3/16TYP 2 7/8 3 13/32 3 3/16TYP (2).312"DiaK.O.'s 13 13/16 17 3/32 5 1/2 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) SP4511X 5 5/8 5 2 1/4 (12) K.O. for .50", .75'", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (12) K.O. for .50", .75'", 6 19/32 1", 1.25", 1.5", 2", 2.5", 3" Conduit 2 3/8 11/16 1 13/16 12 3/4 6 19/32 6 7/16 7 1/2 21 1/2 14 3 13/32 SP4611X 23 3/4 5 5/8 19 15/16 2 13/16 2 13/16 (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) 31 1/2 351/2 9 9 9 47 7/16 9 47 7/16 9 9 12 3/4 12 3/4 5 19/32 5 2 15/32 2 1/4 (6) K.O. for .50", .75", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (1) K.O. for .5" Conduit 23 9/16 22 23/32 (2) .312" Dia K.O.'s (6) K.O. for .50", .75", 1", 1.25", 1.5", 2", 2.5", 3" Conduit 6 19/32 (1) K.O. for .5" Conduit (2) .312" Dia K.O.'s 27 1/4 26 3/8 (5) K.O. for 1", 1.25", 1.5", 2", 2.5", 3" Conduit 7 1/2 7 1/2 3 3/4 5 1/8 2 7/8 1 5/16 2 3/4 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 2 3/8 11/16 (1) K.O. for .5", 3 3/16TYP .75", 1", 1.25" Conduit 1 13/16 3 13/32 2 7/8 2 3/4 1 5/16 22 29/32 7 13/16 19 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5 3/16 3 3/4 2 1/16 11/16 (1) K.O. for .5", .75", 1", 1.25" Conduit 3 3/4TYP 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) SP5411X 2-78 (5) K.O. for 1", 1.25", 1.5", 2", 2.5", 3" Conduit 7 13/16 26 19/32 22 21/32 SP6412R/RJ/RJB 2 7/8 4 3/4 Meter Centers Uni-Pak Metering Wiring, Dimensional & Knockout Diagrams 19 15/16 5 5/8 23 23/32 5 5/8 2 13/16 2 13/16 2 (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) 53 1/8 45 3/16 METER CENTERS 9 9 38 7/16 38 7/16 9 9 12 3/4 12 3/4 5 19/32 2 15/32 5 2 1/4 (12) K.O. for .50", .75", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (1) K.O. for .5" Conduit (2) .312" Dia K.O.'s 23 9/16 22 23/32 (1) K.O. for .5" Conduit (2) .312" Dia K.O.'s (12) K.O. for .50", .75", 1", 1.25", 1.5", 2", 2.5", 3" Conduit 6 19/32 5 1/8 3 3/4 2 7/8 1 13/16 1 5/16 3 3/16TYP 3 13/32 7 13/16 2 3/4 (10) K.O. for 1", 1.25", 1.5", 2", 2.5", 3" Conduit 4 3/4 3 13/32 7 13/16 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 2 1/16 2 7/8 11/16 3 3/4TYP 1 13/16 5 3/16 3 1 5/16 2 /4 2 7/8 2 7/8 2 3/8 11/16 (1) K.O. for .5", 3 3/16TYP .75", 1", 1.25" Conduit 22 29/32 19 27 1/4 26 13/32 7 1/2 3 3/4 7 1/2 (10) K.O. for 1", 1.25", 1.5", 2", 2.5", 3" Conduit SP6511X (1) K.O. for .5", 3 3/4TYP .75", 1", 1.25" Conduit 26 19/32 22 11/16 4 3/4 SP6512R/RJ/RJB 19 15/16 5 5/8 23 23/32 5 5/8 2 13/16 2 13/16 (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) (2) Removable HUB plate covering HD Type Hub opening (Max. 4" Conduit) 53 1/8 45 3/16 9 9 38 7/16 38 7/16 9 9 12 3/4 12 3/4 5 19/32 2 15/32 5 2 1/4 (12) K.O. for .50", .75", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (1) K.O. for .5" Conduit (2) .312" Dia K.O.'s 23 9/16 22 23/32 6 19/32 (12) K.O. for .50", .75", 1", 1.25", 1.5", 2", 2.5", 3" Conduit (1) K.O. for .5" Conduit (2) .312" Dia K.O.'s 5 1/8 3 3/4 2 7/8 1 13/16 1 5/16 3 3/16TYP 3 13/32 7 13/16 2 3/4 (1) K.O. for .5", 3 3/16TYP .75", 1", 1.25" Conduit 22 29/32 19 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) SP6611X 2 3/8 11/16 1 13/16 3 13/32 27 1/4 26 13/32 (10) K.O. for 1", 1.25", 1.5", 2", 2.5", 3" Conduit 7 1/2 3 3/4 7 1/2 (10) K.O. for 1", 1.25", 1.5", 2", 2.5", 3" Conduit 3 3/4TYP 4 3/4 2", 2.5", 3", 3.5", 4" KO's with provisions (Max. 4" Conduit) 5 3/16 1 5/16 2 3/4 2 7/8 2 7/8 7 13/16 11/16 (1) K.O. for .5", 3 3/4TYP .75", 1", 1.25" Conduit 26 19/32 22 11/16 2 1/16 2 7/8 4 3/4 SP6612R/RJ/RJB SP8612R/RJ/RJB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-79 Meter Centers Uni-Pak Metering: Lever Bypass METER CENTERS 2 Wiring, Dimensional & Knockout Diagrams Note: 2, 3, 4 gang models are the same dimensions on the top and bottom. SP4212RJL SP4312RJL Note: 5 & 6 gang models use the same dimensions. SP6512RJL 2-80 SP4412RJL Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog SP6612RJL Meter Centers Accessories: Modular & PAK Metering Description List Price $ SBJ1 SBJ4 364.00 401.00 BE1 1470.00 BE4 1586.00 873.00 WMEX4U 1088.00 WMMBK 216.00 WMEP ECHR075 ECHR100 ECHR125 ECHR150 ECHR200 ECHV200 ECHV250 ECHV300 ECHV350 ECHV400 42.50 40.00 39.50 39.50 40.00 70.00 91.00 125.00 182.00 274.00 362.00 EC56854 EC56855 EC56856 EC56857 EC56858 EC56933S NSK400 NSK600 PLK400 PLK600 178.92 178.92 178.92 263.06 119.28 76.68 157.00 207.00 183.00 183.00 Bussed Elbow permits the continuation of the main bus around corners to adjacent wall. Indoor use only. Bussed Corner Elbow SBJ1 use on 125 & 200Amp sockets only. One pass thru bushing supplied with each WMMB device When adding modular metering modules to old installation, replace metal end closure plate with plastic end closure plate. Item is a kit consisting of adapter plate & RX type hub. Bussed Spacer SBJ4 Catalog Number Universal PAK & MOD Access. Sealing Ring- Snap-on, Stainless Steel Sealing Ring- Screw-type, Stainless Steel Sealing Ring- Snap-on, Aluminum 2-pole Bank Filler Plate QP 125A Max Breaker 4-pole Blank Filler Plate QPP 225A Max Breaker 4-pole Blank Filler Plate With QP (2" wide) 125A breaker installed Plastic Cover Plate- for ring style socket Plastic Cover Plate- for ringless style socket Meter By-pass Jumper 4&5 Jaw 5th Jaw Kit for Modular Metering 3, 6, 9 O’clock Positions Ins. 5th Jaw Kit for Modular Metering 3, 6, 9 O’clock Positions WMEX1U Spacer Included with each meter stack. Not included with mains or tap boxes - order separately if using a switch, breaker, or tap box module on the load side. Description For METER CENTERS WMEX1U 2 Modular Metering Accessories Single Bolt Joint, 1-Phase, 3-Wire, 1200A maximum Single Bolt Joint, 3-Phase, 4-Wire, 1200A maximum Indoor Bussed Elbow, 1-Phase, 3-Wire, 1200A maximum Indoor Bussed Elbow, 3-Phase, 4-Wire, 1200A maximum Outdoor Bussed Extension, 1-Phase, 3-Wire, 1200A maximum Outdoor Bussed Extension, 3-Phase, 4-Wire, 1200A maximum Pass-Thru Bushing-for use with Underground Pull Box End Closure Plate 3/4" HR Type Hub for Service Entrance Module 1" HR Type Hub for Service Entrance Module 1-1/4" HR Type Hub for Service Entrance Module 1-1/2" HR Type Hub for Service Entrance Module 2" HR Type Hub for Service Entrance Module 2" HV Type Hub for Service Entrance Module 2-1/2" HV Type Hub for Service Entrance Module 3" HV Type Hub for Service Entrance Module 3-1/2" HV Type Hub for Service Entrance Module 4" HV Type Hub for Service Entrance Module PAK Metering Accessories 2" HD Type Hub for New Uni-PAK 2-1/2" HD Type Hub for New Uni-PAK 3" HD Type Hub for New Uni-PAK 3-1/2" HD Type Hub for New Uni-PAK 4" HD Type Hub for New Uni-PAK Closure Plate for HD Hub Opening Nema Stud Kit for New 400A Uni-PAK Nema Stud Kit for New 600A Uni-PAK Parallel Lug Kit for New 400A Uni-PAK (2) 250 kcmil Parallel Lug Kit for New 600A Uni-PAK (3) 250 kcmil Catalog Number Selection For use on old and new style pak units. Filler plate is not needed for NEW PAK. (2) Required per 1-Phase meter socket. Residential type ring and ringless- 200amp max. Meter cannot be installed while in use. For use with ECPP cover plate. List Price $ SRSS SRSW SRSTD 19.38 25.03 17.47 ECCP1U 14.20 ECCP2U 14.20 ECCP3U 14.20 ECPP ECCP3U ECJS 19.00 14.20 36.74 ECMM5J 23.50 ECMMI5J 20.50 Modular units only. Add “12” suffix for 12" elbow: BE112 and BE412. For inches / millimeters conversion, see Application Data section. Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-81 Meter Centers Modular Metering Peplacement Parts Kits METER CENTERS 2 Selection ▪ ▪ ▪ ▪ Eliminate the need for Special orders Stocked and ready for shipment All kits come with appropriate hardware and instruction sheet for safe installation Packages are stocked in specified Quantities and cannot be substituted or changed Part Number Breaker Covers GMBC1 Description Contents List Price $ Group Metering Breaker Cover - 125Amp Positions Group Metering Breaker Cover - 200Amp Positions One Top and bottom black plastic breaker cover piece, 1 gasket, and a locking clip Top and bottom black plastic breaker cover pieces, gasket, and locking clip 10.00 GMBC2 Meter Covers 햲 MMCVR1 Modular Metering Tenant Covers 125A Ring Style 10.00 MMCVR1R Modular Metering Tenant Covers 125A Ringless MMCVR2 Modular Metering Tenant Covers 200A Ring Style MMCVR2R Modular Metering Tenant Covers 200A Ringless PAKMCVRR Tenant cover for Ring Style Uni-Pak Meter Center PAKMCVRL Tenant cover for RingLess Uni-Pak Meter Center 1 Ringstyle meter cover welded with support brackets and painted 1 Ringless style meter cover welded with support brackets and painted 1 Ringstyle meter cover welded with support brackets and painted 1 Ringless style meter cover welded with support brackets and painted 1 Ringstyle meter cover welded with support brackets and painted 1 Ringless style meter cover welded with support brackets and painted Breaker Mounting assembly includes provision for 125 or 200A breaker Meter Socket assembly includes jaws, straps, and hardware - see picture 3 above 14.00 22.00 24.00 22.00 All loose screw bags, labels, instruction sheet and aluminum sealing ring (No SBJ) All loose screw bags, labels, instruction sheet and aluminum sealing ring (No SBJ) All loose screw bags, labels, instruction sheet and aluminum sealing ring (No SBJ) All loose screw bags, labels, instruction sheet and aluminum sealing ring (No SBJ) 16.00 Meter Socket/Breaker Mounting MMBMT1 MMSCK1 MMBMT2 MMSCK2 Loose Parts Kits MMPK11 햲 Modular Modular Modular Modular Metering Metering Metering Metering Breaker Mounting S/A 125A Meter Socket Assembly 125A Breaker Mounting S/A 200A Meter Socket Assembly 200A Modular Metering Loose Parts Kit 125A 1 PHASE MMPK13 Modular Metering Loose Parts Kit 125A 3 PHASE MMPK21 Modular Metering Loose Parts Kit 200A 1 PHASE MMPK23 Modular Metering Loose Parts Kit 200A 3 PHASE 10.00 10.00 10.00 10.00 10.00 10.00 16.00 16.00 16.00 Order CCK or CCK1 for Ring to Ringless Cover Conversion Kit. 2-82 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI Meter Centers Modular Metering - Bus Duct Modules Selection Busway Application Common Bus Duct Units (1) Mechanism Amperes (3) Phase Type 1 400 3 1 3 600 3 1 3 1 800 3 1 3 1000 1200 1 3 1 3 Class T Fuse LXD6 Breaker Class T Fuse JXD6 Breaker Class T Fuse NXD6 Breaker NXD6 Breaker MC4BD MC44BD MS4UBD MS44UBD MC6BD MC64BD MS6UBD MS64UBD MC8BD MC84BD MS8UBD MS84UBD MC10BD MC104BD MC12BD MC124BD AIC Rating (2) 65,000 100,000 65,000 100,000 65,000 100,000 65,000 65,000 List Price $ 4777.00 7528.00 2679.00 4716.00 7250.00 11326.00 5231.00 8766.00 11515.00 14810.00 8630.00 15262.00 13348.00 18484.00 19445.00 27373.00 1 - All devices are build to order.Tap stack & SBJ sold separately. 2 - 100K AIC Breaker Units available - contact sales office for more information. 3 - Alternate amperages for breaker modules available. Contact sales office for more info. Tap Stacks Tap stacks save space by connection Siemens’ Sentron Busway directly to speciallydesigned Siemens circuit breaker, switch, or tap box modules. Common modules are listed above. Tap stacks require end-user to purchase an additional single bolt joint coupler and are for indoor use on end-feed applications only. For inches / millimeters conversion, see Application Data section. Tap stacks are produced with the busway. Contact sales office for more information. Discount Schedule RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-83 METER CENTERS 1 JXD2 Breaker Catalog Number 2 Siemens offers a direct busway to modular metering connection. When six or less disconnects are present a connection can be made directly to the meter module. If a main is needed Siemens offers breaker options up to 1200amps and switch options up to 800amps. All breaker and switch modules are available with up to 100,000 AIC ratings, are UL listed, and carry a Nema 1 (indoor) rating. Common service entrance modules are listed to the right. Lead time may apply. See below for spacing considerations. EUSERC Commercial Metering Commercial Type BY Meter-Main Combinations Selection METER CENTERS 2 Design/Performance Features ▪ Outdoor/Indoor—one design for either installation. ▪ Ring Type—meets requirements for various ring type locking provisions. ▪ Test Block Bypass Installed—easy servicing without interruption. ▪ Main Breaker Field Installed—adaptable to the job. ▪ Main T-Fuse puller factory installed (less fuses)—adaptable to the job. Industry Specifications ▪ ANSI – Standard #C 12.7 ▪ NEMA – Standard #250 Standard #PB1 UL – Standard #414 ▪ Standard #67 ▪ EUSERC – SEC #300 Systems ▪ 100/200 amperes maximum meter ▪ 120/240V AC, 1ø3W, 4 jaw ▪ 208Y/120V AC, 3W network, 5 jaw or 3ø4W, 7 jaw ▪ 240V AC, 1ø3W, 3ø3W, or 3ø4W, 4, 5 or 7 jaw ▪ 10,000 to 100,000 AIC In addition to local code and National Electrical Code requirements, the serving utility may have special requirements for metering devices. Confirm meter socket acceptance prior to order placement. Ring-type Meter-Main Combinations 100-200Amp Max. 240V AC Max Amps Cont. Max Duty AIC 65,000 Tenant Main CB Provision Circuit QP/ Breaker QPH/ Provision HQP Service Jaws 1Phase- 4 3 Wire 3 Phase7 4 Wire 1 Phase4 3 Wire 100 100,000 T-Fuse Puller Service Feed Dimensions (inches) Height Width Depth MM0202L1100EY OH 36.00 12.50 4.88 KO Fig. 1 Wire Range AL/CU QJ2/ Circuit QJH2/ Breaker QJ2H/ Provision HQJ2H Hub List Provision Price $ #6-2/0 Box Lug 854.00 RX MM0303L3100EY OH 36.00 12.50 4.88 1 #6-2/0 Box Lug 1263.00 MM0202F1100EY OH 36.00 12.50 4.88 1 #6-2/0 Box Lug 1734.00 MM0202F1100CEY OH/UG 24.00 20.13 4.88 3 #6-2/0 Box Lug 1586.00 RX None 3Phase4 Wire 35,000 Catalog Number MM0303F3100EY OH 36.00 12.50 4.88 1 #6-2/0 Box Lug 2322.00 MM0303F3100CEY OH/UG 24.00 20.13 4.88 3 #6-2/0 Box Lug 2121.00 MM0202L1200EY OH 45.00 14.25 6.38 2 #1/0-250 kcmil 1661.00 MM0202L1200CEY OH/UG 30.00 24.25 6.38 4 #1/0-250 kcmil 7 1 Phase4 3 Wire 1776.00 HC 3 Phase7 4 Wire MM0303L3200EY OH 45.00 14.25 6.38 2 #1/0-250 kcmil 2207.00 MM0303L3200CEY OH/UG 30.00 24.25 6.38 4 #1/0-250 kcmil 2356.00 MM0202F1200EY OH 45.00 14.25 6.38 2 #1/0-250 kcmil 2322.00 MM0202F1200CEY OH/UG 30.00 24.25 6.38 4 #1/0-250 kcmil 200 1 Phase4 3 Wire 100,000 T-Fuse Puller 3 Phase7 4 Wire Dimensions shown are representative of outside box length, width & depth (± 1⁄8”) and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Consult factory for specific details if required. 2-84 2471.00 HC None MM0303F3200EY OH 45.00 14.25 6.38 2 #1/0-250 kcmil 3004.00 MM0303F3200CEY OH/UG 30.00 24.25 6.38 4 #1/0-250 kcmil 3250.00 Price Price does not include breaker or fuses. does not include fuses. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule RESI EUSERC Commercial Metering Commercial Type BY Meter-Load Center Combinations MC1224B1100CEY Selection MC2442F3200CEY 2 METER CENTERS Design/Performance Features ▪ Outdoor/Indoor—one design for either installation. ▪ Ring Type—meets requirements for various ring type locking provisions. ▪ Test Block Bypass Installed—easy servicing without interruption. ▪ Main Breakers Factory Installed. ▪ Main T-Fuse Pullers Factory Installed (less fuses). ▪ Compact wall-hung design reduces material and labor costs. Systems ▪ 100A, 200A maximum meter ▪ 120/240V AC, 1ø3W, 4 jaws ▪ 240V AC, 3ø4W, 7 jaws ▪ 10,000 thru 100,000 AIC Accessories — See below. In addition to local code and National Electrical Code requirements, the serving utility may have special requirements for metering devices. Confirm meter socket acceptance prior to order placement. Ring Type Commercial Meter-Load Center Combinations with Test Block Bypass 240 V AC Max. Amps Main Cont. Breaker Duty Factory Inst. AIC Rating No. of Max. Spaces Circuits Service Catalog Number STD. AIC MAX AIC Dimensions (inches) Wire Wire Range AL/CU KO Fig. List Price Height Width Depth Hub Prov. 36.00 24.00 30.00 12.50 20.13 25.75 4.88 4.88 6.38 RX RX HC #6-2/0 Box Lug #6-2/0 Box Lug #1/0-250 kcmil 7 8 9 1663.00 2 1727.00 2 3116.00 2 100,000 26.00 100,000 42.00 24.25 27.25 4.88 6.38 RX HC #6-2/0 Box Lug #1/0-250 kcmil 10 11 3135.00 4 3924.00 4 Notes 1 Phase—3 Wire, 4 Jaws, Factory Installed Main Breaker 100 Q2100 200 QN2200RH 10 12 24 20 24 40 OH MC1020B1100EY 10,000 OH/UG MC1224B1100CEY 10,000 OH/UG MC2440B1200CEY 10,000 65,000 42,000 22,000 3 Phase—4 Wire, 7 Jaws, Factory Installed T-Fuse Puller 100 200 T-Fuse Prov. 18 T-Fuse Prov. 24 30 42 OH/UG MC1830F3100CEY 100,000 OHUG MC2442F3200CEY 100,000 Safety Socket Accessories Description Hubs Conduit Size 1" 11⁄4" 11⁄2" 2" 2" 21⁄2" 21⁄2" 3" Closure Plates Adapter Plates Bottom Only Dimensions Catalog Number EC38596 EC38597 EC38598 EC38599 ECHC200 EC38600 ECHC250 ECHC300 EC38595 ECHC000 37.81 37.81 23.96 23.96 72.00 107.57 108.00 175.00 38.34 24.00 ECHCRXA 22.50 shown are representative of outside box length, width & depth and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Discount Schedule RESI List Price $ UL Description Catalog Number Fifth Jaw 100A 200A UX001WL UX005B List Price $ 23.50 103.00 Listed to field change main breaker to higher AIC. does not include fuses. Price Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-85 EUSERC Commercial Metering Type BY Wiring Diagrams Selection Commercial All-In-Ones MC1224B1100CEY METER CENTERS 2 MC1020B1100EY MC1830F3100CEY 2-86 MC2442F3200CEY Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MC2440B1200CEY EUSERC Commercial Metering Type BY Dimensions & Knockout Data Selection Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 2 Figure 1 METER CENTERS Knockout Code—Conduit Sizes = 1⁄4 A = 1⁄2 B = 1⁄2, 3⁄4 C = 1⁄2, 3⁄4, 1 D = 1⁄2, 1 E = 1⁄2, 3⁄4, 1, 11⁄4 F = 1⁄2, 11⁄4, 11⁄2 G = 3⁄4 H = 3⁄4, 1 J = 3⁄4, 1, 11⁄4 K = 3⁄4, 11⁄4 M = 3⁄4, 1, 11⁄4, 11⁄2 N = 3⁄4, 1, 11⁄4, 11⁄2, 2 P = 1, 11⁄4 Q = 1, 11⁄4, 11⁄2 R = 1, 11⁄4, 11⁄2, 2 S = 1, 11⁄4, 11⁄2, 2, 21⁄2 T = 11⁄4 U = 11⁄4, 11⁄2 V = 11⁄4, 11⁄2, 2 W = 11⁄4, 2 X = 11⁄4, 11⁄2, 2, 21⁄2 Y = 11⁄2, 2 Z = 11⁄2, 2, 21⁄2 AA = 11⁄2, 2, 21⁄2, 3 BB = 11⁄2, 2, 21⁄2, 3, 31⁄2 CC = 2, 21⁄2, 3, 31⁄2 EE = 2, 21⁄2, 3 FF = 21⁄2, 3 GG = 21⁄2, 3, 31⁄2 HH = 21⁄2, 3, 31⁄2, 4 JJ = 31⁄2, 4 LL = 3 VV = 2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-87 METER CENTERS 2 Notes 2-88 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3SPEEDFAX TM 2007-2008 Safety Switches Contents 3-6 3-6 3-7 3-8 3-9 3-10 3-11 3-12 3-13 3-14 3-15 3-16 3-17 3-17 3-17 3-17 3-17 3-18 3-18 3-19 3-19 3-19 3-20 3-20 3-20 3-20 3-20 3-21 – 3-24 3-25 – 3-26 3-27 3-28 3-29 – 3-30 3-31 3-32 – 3-33 3-34 SAFETY SWITCHES Residential Commercial Industrial 3-2 3-3 3-4 3-5 3 Safety Switch Guide Form Specifications Feature Comparison Enclosure Types Catalog Numbering System General Duty Safety Switches Plug Fuse Enclosed Type, 120/240V Fusible—Selection 60A Special Application Type, 240V Non-Fusible—Selection General Duty Switches—Features 240V Fusible and Non-Fusible—Selection Heavy Duty Safety Switches Heavy Duty Switches—Features 240V Fusible—Selection 600V Fusible—Selection 600V Non-Fusible—Selection Type 4/4X and 12 with Viewing Window—Selection Special Applications Safety Switches 4-Pole and 6-Pole—Selection Interlocked Receptacle—Selection Non-Metallic—Selection Accessories—General and Heavy Duty Switches Class R Fuse Clips Class J Fusing Class T Fuse Adapter Kits Neutral Kits 200% Neutral Kits Auxiliary Contacts Fuse Puller Kits Copper Lug Kits Equipment Ground Kits Isolated Ground Kits Interchangeable Hubs Compression Lug, Neutral Barrier Kits Lugs and Wire Ranges Multiple Padlocks Kirk-Key Interlocks Dimensions and Weights General and Heavy Duty Switches Type 1 and 3R Knockout Diagrams Non-Metallic and Receptacle Switch Dimensions 4-Pole and 6-Pole Switch Dimensions Double-Throw Switches Selection Dimensions Enclosed Rotary Disconnect Switches VBII Safety Switch Replacement Parts Type VBII Safety Switches Guide Form Specifications Product Overview Heavy Duty Double Throw Application General Duty Switches are intended for applications where reliable performance and continuity of service are needed, but where duty requirements are not severe and usual service conditions prevail. (These switches are intended for use primarily with supply circuits rated 240V AC or less where the available fault current is less than 100,000A when used with Class R or T fuses or 10,000A max. when used with Class H fuses.) Heavy Duty Switches are intended for use in applications where: 1. Rugged construction, reliable performance, continuity of service and ease of maintenance are emphasized, or 2. Available fault currents higher than 10,000A are likely to be encountered, such as in manufacturing plants, mass production industries, and commercial, institutional and other large buildings served by network systems or transformers of higher capacities. 3. System voltage is 600V AC or DC Max. 4. A Type 12 or 4 / 4X enclosure is required. Double throw switches are intended to transfer loads from one power source to another. All 2 & 3 pole double throw switches are suitable for use as service equipment. All are UL Listed. Switches are rated for use on systems with an available fault current of up to 10,000 AIC when protected with Class H fuses or either 100,000 or 200,000 AIC when protected with Class R, J or Class T fuses. They can also be used to connect a single source of power to either of two loads, In this application it is necessary to field modify fusible switches so that the fuses are on the load side of the switching mechanism. Short Circuit Withstand Ratings Suitable for use on systems capable of delivering not more than 100,000 RMS symmetrical amperes of fault current as follows: Suitable for use on systems capable of delivering not more than 200,000 RMS symmetrical amperes of fault current as follows: SAFETY SWITCHES 3 General Duty Sw. Rating 30-600A 30-600A 30-600A 100-600A Fuses Cover Interlocks AIC Rating 10,000 10,000 100,000 100,000 Protective Device Circuit Breaker Class H Fuse Class R Fuse Class J or T Fuse Sw. Rating & Tpye All Heavy Duty & DT 30-600A HD & DT 60A Compact HD GD & 4P DT 30-600A HD 30-600A DTF & DTNF DT 800 & 1200A HD & DT AIC Rating 10,000 10,000 100,000 100,000 200,000 200,000 200,000 Protective Device Circuit Breaker Class H Fuse Class R, J or T Fuse Class R, J or T Fuse Class R, J or T Fuse Class R, J or T Fuse Class L or T Fuse Fusible switches will accept the following UL class fuses: Fusible switches will accept the following UL class fuses: Fusible switches will accept the following UL class fuses: 30 “LF” - 30A max plug Fuses 30-600A “GF” Class H & K, Class R with kit 100-600A “GF” Class J-move base 100-200 “GF” Class T with kit 400-600A “GF” Class T-move bases 30-600A “HF” Class H & K, Class R with kit 30-600A, 600V “HF” Class J-move base 100-600A, 240V “HF” Class J-move base 100-200A “HF” Class T with kit 400-600A “HF” Class T-move bases 800-1200A “HF” Class L, Class T with kit 30-200A “DT” & “F” Class H & K, Class R with kit 30 & 60A 600V “DT” Class J-move base 100-200A “DT” Class J-move base, Class T with kit 400-600A “DT” Class J-standard, Class T-move bases 400A “F” Class T-standard Voidable – cover interlocks on switches prevent the switch door from being opened when in the “ON” position. No cover interlock on 30A Type 3R or on plug fuse type switches. Voidable dual cover interlocks standard on all heavy duty switches. Prevents cover from being opened when switch is in the “ON” position and prevents switch from being turned “ON” when door is opened. Dual cover interlocks standard on all double throw switches. Prevents cover from being opened when switch is in the “ON” position and prevents switch from being turned “ON” when door is opened. Underwriters’ Listed by UL under file #E4776 as enclosed switches and also suitable for use as service equipment (where applicable). Laboratories, Inc. UL98 Enclosed and Deadfront Switches. NEMA Specifications Meet NEMA standard KS-1-1990 for type GD switches. Meet NEMA standard KS-1-1990 for type HD switches. Meet NEMA standard KS-1-1990 type GD for “DTG” & type HD for “DT”, “F” & “NF” switches. Groundable Neutral Fusible switches have groundable neutral blocks factory installed. Non-fusible switches accept field addable neutrals. All neutrals are bondable for service entrance use. All switches (both Fusible and Non-Fusible) are either supplied with factory installed neutrals or accept field addable neutrals. All neutrals are bondable for service entrance use. All except 4 pole switches will accept field addable neutrals except that “DTG” 100 & 200A switches are also available with factory installed neutrals. All neutrals are bondable for service entrance use. Padlocks Padlockable cover latch. OFF padlock provisions on handle. Padlockable cover latch and multiple OFF padlock provisions on handle. Padlockable cover latch and multiple OFF padlock provisions on handle. HP & Load Break Ratings All General Duty, Heavy Duty and Double Throw Switches are both load break and horsepower rated. The protective device can either be a fuse installed in a fusible switch or an upstream fuse or circuit breaker protecting a non-fusible switch. The ampere rating of the upstream protective device must not exceed the switch ampere rating. 3-2 All 4 pole and fusible double switches with catalog numbers starting with “F” are rated 100,000 AIC max. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Class T kit available for 240V max. applications on 1200A switches. Feature Comparison Product Overview General Duty Heavy Duty Double Throw Features / Ratings ▪ ▪ ▪ 30 thru 600 Amps ▪ ▪ 800 and 1200 Amps ▪ ▪ 240 Volt AC ▪ ▪ 600 Volt AC ▪ ▪ 250 Volt DC ▪ ▪ 600 Volt DC ▪ ▪ Double-break visible blade design (30-200A) ▪ ▪ ▪ Quick-make, quick-break switching action ▪ ▪ ▪ Highly visible ON/OFF handle indication Handle design for hook stick operation ▪ ▪ ▪ ▪ Padlockable cover latch ▪ ▪ ▪ Padlockable handle ▪ Single voidable cover interlock ▪ ▪ Dual voidable cover interlock ▪ ▪ ▪ Type 1 enclosure ▪ ▪ ▪ Type 3R enclosure ▪ ▪ Type 12 enclosure ▪ ▪ Type 4 / 4X enclosures ▪ ▪ ▪ Generous wiring gutters that meet UL and NEC wire-bending space requirements ▪ ▪ ▪ Lugs suitable for copper or aluminum at 60˚ or 75˚C ▪ ▪ ▪ CU/AL wire lugs that meet UL 486B requirements ▪ ▪ Suitable for field-convertible compression connectors ▪ ▪ ▪ All plated copper current carrying parts (except lugs) ▪ ▪ ▪ Spring reinforced Fuse Clips (except 30A general duty) ▪ ▪ Clear pivoting line terminal shield ▪ ▪ Replacement parts ▪ Field addable 200% neutral ▪ ▪ ▪ 400 ▪ ▪ ▪ Provisions for UL Class J and L Fuses ▪ ▪ Metal nameplate ▪ ▪ Aux. switch kits ▪ Type 4X with stainless steel interior parts ▪ Rolled flange enclosure design (30-200A) ▪ UL approved HP ratings for high efficiency motors ▪ & 600A fusible, double-throw switches accept only Class J or T fuses. general duty switches have fuse clips constructed of spring type copper. 30A Provisions for UL Class T, R and H Fuses ▪ ▪ SAFETY SWITCHES ▪ 3 ▪ ▪ on Isolated ground kits Not supplied on 30A outdoor & plug fuse switches. Type VBII in stainless steel enclosures. 30-200A 60-200A. in operation off Double Break Switching Action Like the time-proven Vacu-Break Design, the Siemens VBII double break switching action breaks the arc in two places in 30-200A ratings. This reduces heat generation and increases switching speed by doubling the breaking distance. The result is enhanced performance and increased longevity. We also provide the most visible blade design available today. Unlike conventional knife blade switches, the blades are self-aligning to ensure positive contact. In addition, they have no wear and friction point since the “electrical hinge” has been eliminated. The result is a very fast, positive and reliable switching action for even the most severe applications. 200A general duty switches have aluminum neutral assemblies. GD & DT and 100-1200A HD switches will accept Class T fuses. 100-600A Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-3 Safety Switches General Duty and Heavy Duty Product Overview Enclosure Types □ A Type 1 enclosures are intended for indoor use primarily to provide protection against contact with the enclosed equipment in locations where unusual service conditions do not exist. SAFETY SWITCHES 3 B Type 3R enclosures are intended for outdoor use primarily □ to provide a degree of protection against falling rain and sleet and must remain undamaged by the formation of ice on the enclosure. They are not intended to provide protection against conditions such as dust, internal condensation, or internal icing. □ C Type 4, 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust, rain, splashing water and hose-directed water. They are not intended to provide protection against conditions such as internal condensation or internal icing. Also meets 4X definition by providing a high degree of protection against corrosion. Siemens 30-200A stainless steel 4X switches are supplied stainless interior parts and hardware as standard. □ A □ B □ C □ D □ E □ D Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust, rain, splashing water and hose-directed water. They are not intended to provide protection against conditions such as internal condensation or internal icing. □ E Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt and dripping water. They are not intended to provide protection against conditions such as internal condensation. Type 7/9 enclosures for use in hazardous locations. Use with molded case switches listed on page 6-62. For enclosure catalog numbers and dimensions see page 5-2 & 5-12. Note: Type 1 60A General Duty and Type 1 30 & 60A Heavy Duty Switches have tangential knockouts which are UL approved for bonding conduits for non-service entrance conductors. Load Break Ratings Horsepower Ratings All Siemens safety switches are load break rated. The load break rating is assigned by UL after the switching unit has successfully performed the following tests for general use enclosed switches: All Siemens safety switches, where appropriate, are horsepower rated. The assignment of such ratings is made by UL only after the switching unit has undergone tests to determine its acceptability. In addition, the unit must successfully perform on an overload test series which includes repeated interruption of the locked rotor current of the motor for which it is to be rated as follows: Load Break Ratings Switch Ampere Rating Number of ON/OFF Operations per Minute 30–100 6 6000 4000 10000 200 5 6000 2000 8000 400 4 1000 5000 6000 600 3 1000 4000 5000 Number of Operations With Without Current Current Total 800 2 500 3000 3500 1200 1 500 2000 2500 Horsepower Ratings Max HP Rating Number of ON/OFF Operations per minute Number of Cycles of Operation 100 6 50 500 1 10 VBII Type 12 switches are also rated 3R & 3S for outdoor use. Type 3R is defined in B above. 3S rated enclosures provide a degree of protection against windblown dust and allow operation when the enclosure is ice laden. 3-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog Numbering System Type VBII Safety Switch Catalog Numbering System H F 3 6 4 Product Overview N CH CJ CR CU G H L PN W L = General Duty 10k AIC Max. (Plug Fused & 60A Max Non-Fused) G = Gen. Duty H = Heavy Duty DT = Double Throw DTG = General Duty DT = = = = = = = = = Crouse-Hinds Receptacle Factory J Fuse Spacings Class R Clips Installed Factory-Installed Copper Lugs Factory-Installed Ground Bar Height or Size Reduced Oversized Enclosure Pyle-National Receptacle Viewing Window 3 Fused or Non-Fused Enclosure Type Omit R S X J XL Number of Poles 1 2 3 4 6 = = = = = = SAFETY SWITCHES F = Fused NF = Non-Fused = = = = = CU Special Applications With: Switch Type 1 2 3 4 6 R Type 1, Indoor Type 3R, Outdoor Type 4 / 4X, Stainless Steel Type 4 / 4X, Non-Metallic Type 12, Industrial Type 4/4X Non-Metallic Less Line & Load Lugs With or Without Neutral Omit = Less Neutral N = With Neutral Voltage Amperes 1 = 120V or 120/240V 2 = 240V 6 = 600V 1 2 3 4 = = = = 30A 60A 100A 200A 5 6 7 8 = = = = 400A 600A 800A 1200A Type VBII Accessories Catalog Numbering System H Switch Type H = Heavy Duty G = General Duty Accessory Type A1 A2 A3 CL = = = = G G2 LC N N2 P R T = = = = = = = = Auxiliary Switch 1/NO and 1/NC Auxiliary Switch 2/NO and 2/NC Auxiliary Switch Low Current Compression Lug Barrier / Mounting Kit Ground Lug Kit Insulated Ground Lug Kit Copper Lug Kit Neutral 200% Neutral Fuse Puller Kit Class R - Fuse Clip Kit Class T - Fuse Kit R 6 4 Amperes 1 2 12 3 23 123 1234 4 56 5678 78 = = = = = = = = = = = 30A 60A 30/60A 100A 60/100A 30/60/100A 30/60/100/200A 200A 400/600A 400/600/800/1200A 800/1200A Maximum Voltage 2 = 240V Max 6 = 600V Max Note: Catalog numbering systems above do not apply to 4-pole double throw switches & accessories. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-5 General Duty Enclosed Switches Plug Fuse and 60A Special Application Type Selection Features SAFETY SWITCHES 3 Compact size Horsepower rated Indoor and outdoor enclosures Quick make-quick break mechanism Visible “ON”-“OFF” indications Padlock-off handle feature Door padlock provision Bondable neutral (where indicated) Lugs suitable for copper or aluminum wire UL Listed Fuses — not included Switches accept Edison base plug fuses ▪ Hubs — see page 3-20 ▪ Lugs — see page 3-20 ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Dimensions (inches) Type Height Width Depth 1 3R 81⁄4 81⁄4 51⁄2 53⁄8 3 31⁄8 Wire Range Table Switch Type Wire Range 120/240 Volt Fusible 30 Amp Cu/Al #14 to #8 AWG 120/240 Volt Non-Fusible 60 Amp Cu/Al #14 to #3 AWG Indoor — Type 1 Ampere Rating Catalog Number Outdoor — Type 3R Horsepower Ratings 1-Phase, 2-Wire List Price $ Ship. Wt. Pkg. of 10 Catalog Number List Price $ Ship Wt. Pkg. of 10 80.00 35 LF111NR 166.00 35 Standard Maximum 120/240 Volt Fusible 1-Pole and Solid Neutral 30 LF111N 120 Volt — 1-Phase, 2-Wire 2-Pole and No Neutral 30 2 120/240 Volt — 1-Phase, 2-Wire Use 2-Pole and Solid Neutral 2-Pole and Solid Neutral 30 ⁄2 1 LF211N 120/240 Volt — 1-Phase, 3-Wire 98.00 35 LF211NR 203.00 35 176.00 35 11⁄2 3 240 Volt Non-Fusible 2-Pole Special Application Switch 60 — — For inches / millimeters conversion, multiply inches by 25.4. Dual horsepower ratings: Std. — applies when non-time delay plug fuses are installed. Max — applies when time-delay plug fuses are installed. 3-6 1 or 2-Pole — No Fuse — LNF222R 240 Volt — 1-Phase, 2-Wire Has service entrance label. UL Listed as “Enclosed Switches” (suitable for use as service equipment where indicated) under File #E4776. (NEMA) — Type G.D. Federal Spec. — W-S-865C — type LD or type NDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog — 10 Bottom cable entry and exit only. No hub provision supplied. GSGK60 is included and factory installed. Line lugs will accept and are UL approved for #14 to #6 Cu/Al cable. Features also apply to 2- and 3-pole, 30A general duty switches on page 3-8. Discount Schedule GDSS General Duty Safety Switches Features (60-600A) Product Overview 5 11 SAFETY SWITCHES 9 3 6 1 8 4 7 2 12 1. Cover interlock 2. Tangential knockouts through 600A for easy conduit lineup 3 10 5. Generous wiring gutters that meet or exceed NEC wire-bending space requirements 3. Quick-make, quick-break operating mechanism that ensures positive operation 6. Visible blade, double-break switch action 4. Provisions for T, R, J, H, and K class fuses (T & J 100-600A) 8. Highly visible red handle grip 7. Positive 2 or 3 point mounting 9. Informative door labeling which includes replacement parts list 10. Handle and cover padlocking provisions 11. Side-hinged door that opens 180 degrees for easier wiring 12. A unique enclosure design that adds rigidity and strength. Its rolled edge prevents cuts and scrapes to conductors and to installer’s hands Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-7 General Duty Safety Switches SAFETY SWITCHES 3 Selection Horsepower Ratings Indoor — Type 1 System Ampere Rating Catalog Number Outdoor — Type 3R 240V AC 2-Phase, 4-Wire 3-Phase, 3-Wire 250 Volt DC Std. Std. Std. Ship Wt.* Catalog Std. Pkg. Number List Price $ 1-Phase, Ship Wt.* 2-Wire Std. Pkg. Std. Max. 127.00 217.00 437.00 907.00 2753.00 2774.00 5438.00 5467.00 035 014 023 047 128 153 133 159 GF221NR GF222NR GF223NR GF224NR GF225NR H GF225NR GF226NR H GF226NR 203.00 334.00 492.00 1287.00 3730.00 3752.00 6897.00 6929.00 035 014 024 048 130 157 135 159 011⁄2 03 071⁄2 15 15 15 15 15 03 10 15 — — — — — — — — — — — — — 203.00 334.00 581.00 1287.00 3262.00 3287.00 6091.00 6124.00 024 015 025 049 136 158 138 161 GF321NR GF322NR GF323NR GF324NR GF325NR H GF325NR GF326NR H GF326NR 302.00 454.00 840.00 1524.00 3934.00 3955.00 8171.00 8205.00 024 015 025 050 138 162 141 165 011⁄2 03 071⁄2 15 15 15 15 15 03 10 15 — — — — — — — — — — — — — 166.00 209.00 492.00 887.00 024 012 023 046 GNF321R GNF322R GNF323R GNF324R 302.00 466.00 840.00 1505.00 024 013 024 047 — — — — 3 10 15 15 — — — — — — — — 0071⁄2 015 030 060 — — — — 05 10 20 40 — — 15 15 — — — — 125 200 — — 50 — List Price $ Max. Max. 240 Volt Fusible 2-Pole, 2-Fuse, and Solid Neutral 030 060 100 200 400 400 600 600 GF221N GF222N GF223N GF224N GF225N H GF225N GF226N H GF226N 240 Volt AC/250 Volt DC 3-Pole, 3-Fuse, and Solid Neutral 030 060 100 200 400 400 600 600 GF321N GF322N GF323N GF324N GF325N H GF325N GF326N H GF326N — — — — — — — — 03 071⁄2 15 25 50 50 75 75 0071⁄2 015 030 060 125 125 200 200 05 10 20 40 50 50 — — 240 Volt AC/250 Volt DC — — — — — — — — 03 071⁄2 15 25 50 50 75 75 0071⁄2 015 030 060 125 125 200 200 05 10 20 40 50 50 — — 240 Volt Non-Fusible 2-Pole or 3-Pole 240 Volt AC/250 Volt DC 030 060 100 200 GNF321 GNF322 GNF323 GNF324 400 600 GNF325 GNF326 * In pounds (lbs). Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. 2275.00 114 4350.00 116 3-8 Use 600V Switch — HNF365R Use 600V Switch — HNF366R These switches are UL-listed for application on grounded B-phase systems. Suitable for use on 3-phase motor loads. Service entrance labeled. Has provision for ECHA type hub. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5 switches per standard package. switches per standard package. reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. 10 Height Discount Schedule GDSS Heavy Duty Safety Switches Features 15 3 20 2 17 11 16 9 3 4 SAFETY SWITCHES 1 5 18 6 13 19 8 14 12 1. Quick-make, quick-break operating mechanism that ensures positive operation. 7 2. Visible blade, double-break switching action. 3. Arc chutes dissipate heat and prolong switch life. 13. Spring reinforced fuse clips that assure reliable contact for cool operation. 4. Highly visible red handle grip. Designed for hook stick operation. 14. Door latch securely holds door closed and allows cover padlocking. 5. Defeatable dual cover interlock. 15. Front removable mechanical lugs that are suitable for CU/AI 60 or 75° C conductors. 6. Center punch provided for field drilling to allow ON padlocking. 10 12. Unique enclosure design increases rigidity and prevents cuts and scrapes to conductors and installer’s hands. 7. Handle can be padlocked in the OFF position with up to (3) padlocks with 5/16" hasps. 8. Generous top, bottom and side gutters that meet or exceed NEC wire-bending space requirements. 16. Lugs are field convertible to copper body and to a wide variety of compression connectors. 17. Hinged clear line terminal shield with probe holes for inspecting or testing line side terminals. 9. Informative door labeling which includes replacement parts list. 18. Embossed aluminum nameplate on Heavy Duty Switches provides highly visible ON/OFF indication. 10. Tangential knockouts through 600A for easy conduit lineup. 19. Drawn cover for increased rigidity and resistance to abuse. 11. Side-hinged door that opens past 180 degrees for easier wiring. 20. Top key hole and bottom mounting holes provide easy 2 or 3 point mounting. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-9 Heavy Duty Safety Switches SAFETY SWITCHES 3 Selection Horsepower Ratings Indoor — Type 1 System Ampere Rating Catalog Number List Price $ Outdoor — Type 3R Ship Wt.* Catalog Std. Pkg. Number List Price $ 240V AC 1-Phase, Ship Wt.* 2-Wire Std. Pkg. Std. Max. 2-Phase, 4-Wire 3-Phase, 3-Wire Std. Std. Max. Max. 250 Volt DC 240 Volt Fusible 2-Pole, 2-Fuse, and Solid Neutral 0030 0060 0100 0200 0400 0400 0600 0600 800 1200 3-Pole, 3-Fuse, and Solid Neutral 0030 0060 0100 0200 0400 0400 0600 0600 0800 1200 (Also used for 2-Pole, 2-Wire Applications) HF221N 257.00 012 HF222N 512.00 018 HF223N 781.00 023 HF224N 1391.00 047 HF225NH 3390.00 129 HF225N 3416.00 153 HF226NH 6237.00 133 HF226N 6266.00 155 HF227N 11116.00 365 HF228N ■ 13688.00 385 HF221NR HF222NR HF223NR HF224NR HF225NRH HF225NR HF226NRH HF226NR HF227NR HF228NR ■ 487.00 914.00 1174.00 1700.00 4536.00 4559.00 8317.00 8351.00 13270.00 18454.00 013 019 024 048 131 157 135 159 365 385 011⁄2 03 071⁄2 15 15 15 15 15 — — 240 Volt AC/250 Volt DC 03 10 15 — — — — — — — — — — — — — — — — — 011⁄2 03 071⁄2 15 15 15 15 15 — — 03 10 15 — — — — — — — — — — — — — — — — — 011⁄2 03 071⁄2 15 03 10 15 — — — — — (Also used for 3-Pole, 3-Wire Applications) HF321N 323.00 014 HF322N 547.00 019 HF323N 906.00 025 HF324N 1570.00 049 HF325NH 4161.00 137 HF325N 4183.00 158 HF326NH 7073.00 139 HF326N 7104.00 161 HF327N 13591.00 375 HF328N 16946.00 395 HF321NR HF322NR HF323NR HF324NR HF325NRH HF325NR HF326NRH HF326NR HF327NR HF328NR 620.00 979.00 1400.00 1906.00 4643.00 4183.00 9354.00 9389.00 17377.00 21095.00 015 020 026 050 138 162 142 165 375 388 — — — — — — — — — — 003 0071⁄2 015 025 050 050 075 075 100 100 0071⁄2 015 030 060 125 125 200 200 250 250 05 10 20 40 50 50 50 50 50 50 240 Volt AC/250 Volt DC — — — — — — — — — — 003 0071⁄2 015 025 050 050 075 075 100 100 0071⁄2 015 030 060 125 125 200 200 250 250 05 10 20 40 50 50 50 50 50 50 240 Volt Fusible 2-Pole, 2-Fuse 0030 0060 0100 0200 3-Pole, 3-Fuse 0030 0060 0100 0200 400 600 800 Type 4/4X Stainless Type 12 Industrial HF221S HF222S HF223S HF224S HF221J HF222J HF223J HF224J 013 019 024 048 729.00 881.00 1274.00 2017.00 013 019 024 048 240 Volt AC/250 Volt DC — — — — 003 0071⁄2 015 025 0071⁄2 015 030 060 05 10 20 40 (Also used for 2-Pole, 2-Wire Applications in 400–800A Ratings) 240 Volt AC/250 Volt DC HF321S HF322S HF323S HF324S HF325S HF326S HF327S ■ ■ Built to order. Allow 2–3 weeks for delivery. * In pounds (lbs). Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. 3-10 2216.00 2507.00 4952.00 7519.00 2307.00 2707.00 5759.00 7965.00 16315.00 23672.00 31830.00 014 020 025 049 154 157 370 HF321J HF322J HF323J HF324J HF325J■ HF326J■ HF327J■ 767.00 939.00 1414.00 2185.00 4741.00 8957.00 16792.00 014 020 025 049 110 161 365 Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. These switches are UL-listed for application on grounded B-phase systems and are suitable for 3-phase motor applications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 011⁄2 3 071⁄2 15 15 15 — 3 10 15 — — — — — — — — — — — — — — — — — — 003 0071⁄2 015 025 50 75 100 0071⁄2 015 030 060 125 200 250 — 10 20 40 50 50 50 When a neutral is required use a field installed neutral kit. Suitable for use as service entrance equipment. Also rated Type 3S/3R. Discount Schedule HDSS Heavy Duty Safety Switches Selection Horsepower Ratings Catalog Number List Price $ Ship Wt.* Catalog Std. Pkg. Number List Price $ 480V AC 600V AC 1-Phase, Ship Wt.* 2-Wire Std. Pkg. Std. Max. 3-Phase, 3-Wire 1-Phase, 2-Wire 3-Phase, 3-Wire Std. Std. Std. Max. Max. 250 600 Volt Volt Max. DC DC 600 Volt Fusible 2-Pole, 2-Fuse 0030 0060 0100 0400 0600 480 Volt AC/600 Volt AC/600 Volt DC HF261 HF262 HF263 HF265■ HF266■ 553.00 656.00 1227.00 4663.00 7813.00 015 020 026 149 150 HF261R HF262R HF263R HF265R ■ HF266R ■ 984.00 1154.00 1788.00 5702.00 11241.00 015 020 027 152 155 03 05 10 — — 071⁄2 20 30 50 50 HF361R HF361R L HF362R HF362RL HF363R HF364R HF365R H HF365R HF366R H HF366R HF367R HF368R 984.00 1128.00 1154.00 1755.00 1788.00 2444.00 5877.00 5903.00 11676.00 11702.00 17975.00 22116.00 015 020 020 025 025 049 137 157 141 161 365 385 333 3 5 5 5 25 — — — — — — 07 ⁄2 071⁄2 20 20 20 50 — — — — — — HF361 568.00 654.00 HF361L HF362 676.00 — — HF363 1301.00 HF364 1830.00 HF365H 4875.00 HF365 4898.00 HF366H 8475.00 HF366 8503.00 HF367 14825.00 HF368 18724.00 14 19 19 — 24 48 136 154 138 157 365 383 HF361NR HF362NR HF363NR HF364NR HF365NR HF366NR HF367NR HF368NR 1062.00 1231.00 1940.00 2586.00 6368.00 12111.00 18815.00 22955.00 015 020 026 050 162 165 375 388 03 05 10 25 — — — — 07 ⁄2 20 30 50 — — — — 1 03 10 15 50 50 10 25 40 — — — — — — — — — — — — 05 10 20 40 50 15 30 50 50 50 HF361N HF362N HF363N HF364N HF365N HF366N HF367N HF368N 666.00 777.00 1426.00 2022.00 5300.00 8955.00 15665.00 19563.00 005 005 015 015 025 050 100 100 150 150 200 200 015 015 030 030 060 125 250 250 400 400 500 500 03 03 10 10 15 30 — — — — — — 10 10 25 25 40 50 — — — — — — 0071⁄2 0071⁄2 015 015 030 060 125 125 200 200 250 250 020 020 050 050 075 150 350 350 500 500 500 500 05 05 10 10 20 40 50 50 50 50 50 50 — — 30 30 50 50 — — — — — — 480 Volt AC/600 Volt AC/250 Volt DC 3-Pole, 3-Fuse and Solid Neutral 0030 0060 0100 0200 0400 0600 0800 1200 — — — — — 480 Volt AC/600 Volt AC/250 Volt DC 3-Pole, 3-Fuse 0030 0030 0060 0060 0100 0200 0400 0400 0600 0600 0800 1200 — — — — — 014 019 025 049 158 161 375 395 1 005 015 025 050 100 150 250 250 015 030 060 125 250 400 500 500 03 10 15 30 — — — — 10 25 40 50 — — — — 0071⁄2 015 030 060 125 200 250 250 020 050 075 150 350 500 500 500 05 10 20 40 50 50 50 50 — 30 50 50 — — — — 600 Volt Fusible (For 2-Pole Applications use outside poles of 3-Pole Switches) 2-Pole, 2-Fuse 0030 0060 0100 0400 0600 480 Volt AC/600 Volt AC/600 Volt DC Type 4/4X Stainless HF261S 2638.00 HF262S 2792.00 HF263S■ 5613.00 HF265S■ 15870.00 HF266S■ 22680.00 015 020 027 153 156 Type 12 Industrial HF261J■ 984.00 991.00 HF262J■ HF263J■ 1547.00 HF265J■ 5357.00 HF266J■ 8768.00 015 020 027 155 156 03 05 10 — — 071⁄2 20 30 50 50 — — — — — 03 10 15 50 50 10 25 40 — — — — — — — — — — — — 05 10 20 40 50 15 30 50 50 50 480 Volt AC/600 Volt AC/250 Volt DC 3-Pole, 3-Fuse 0030 0060 0100 0200 0400 0600 0800 01200 — — — — — HF361S HF362S HF363S HF364S HF365S HF366S HF367S HF368S■ 2681.00 2875.00 5627.00 7997.00 16468.00 24310.00 31062.00 36846.00 013 020 025 049 158 161 370 388 ■ Built to order. Allow 2–3 weeks for delivery. * In pounds (lbs). 60-200A 3-Pole switches are also rated 600V DC. Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. Use 3-Pole switch for 200A applications. Discount Schedule HDSS HF361J HF362J HF363J HF364J HF365J HF366J HF367J ■ HF368J ■ 1001.00 1104.00 1791.00 2507.00 5631.00 10233.00 17430.00 22352.00 014 020 025 049 160 161 365 388 — — — — — — — — — — — — — — — — Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. Suitable for use as service entrance equipment except for 1200 when used on 480 or 600V grounded wye system. Also rated Type 3S/3R. 005 015 025 050 100 150 200 250 015 030 060 125 250 400 500 500 — — — — — — — — — — — — — — — — 0071⁄2 015 030 060 125 200 250 250 020 050 075 150 350 500 500 500 05 10 20 40 50 50 50 50 — 30 50 50 — — — — Indicates oversized enclosure (30A switch with 60A lugs in a 60A enclosure or 60A switch with 100A lugs in a 100A enclosure). 600V DC & 600V DC horsepower rating shown requires (2) poles to be connected in series. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-11 SAFETY SWITCHES System Ampere Rating Outdoor — Type 3R 3 Indoor — Type 1 Heavy Duty Safety Switches SAFETY SWITCHES 3 Selection Indoor - Type 1 System Ampere Catalog Rating Number Ship. Wgt. Outdoor - Type 3R List Catalog Price $ Number Horsepower Ratings Ship. List Wgt. Price $ 240 Volt 480 Volt 1-Phase 3-Phase 1-Phase 600 Volt 250V 3-Phase 1-Phase 3-Phase DC 600V DC 600 Volt Non-Fusible 2-Pole 480 Volt AC / 600 Volt AC / 600 Volt DC 30 60 100 400 600 HNF261 HNF262 HNF263 HNF265■ HNF266■ 12 299.00 HNF261R 19 532.00 HNF262R 24 823.00 HNF263R 109 2893.00 HNF265R 111 5102.00 HNF266R■ HNF361 — HNF362H HNF362 — HNF363 HNF364 HNF365 HNF366 HNF367 HNF368 12 — 11 18 — 23 46 114 116 295 305 13 20 25 113 115 532.00 930.00 1323.00 4075.00 8134.00 — — — 15 15 — — — — — 7 1/2 20 30 50 50 13 19 11 19 24 24 47 118 120 295 307 532.00 900.00 923.00 936.00 1301.00 1338.00 1616.00 4107.00 8147.00 14209.00 18567.00 5 5 10 10 10 15 15 15 15 15 15 10 10 20 20 20 40 60 125 200 250 250 7 1/2 7 1/2 20 20 20 30 50 50 50 50 50 3-Pole — — — — — 10 25 40 50 50 — — — — — 5 10 20 40 50 15 30 50 50 50 480 Volt AC / 600 Volt AC / 250 Volt DC 30 30 60 60 60 100 200 400 600 800 1200 299.00 — 523.00 532.00 — 864.00 1314.00 3068.00 5467.00 10779.00 14642.00 HNF361R HNF361RL HNF362RH HNF362R HNF362RL HNF363R HNF364R HNF365R HNF366R HNF367R HNF368R 20 20 50 50 50 75 125 250 400 500 500 10 10 20 25 25 40 50 50 50 50 50 30 30 40 60 60 100 150 350 500 500 500 5 5 10 10 10 20 40 50 50 50 50 — — — 30 30 50 50 — — — — 600 Volt Non-Fusible 2-Pole 480 Volt AC / 600 Volt AC / 600 Volt DC 30 60 100 400 600 Type 4 / 4X Stainless HNF261S 13 2153.00 HNF262S 20 2521.00 HNF263S■ 25 5137.00 HNF265S■ 113 13612.00 HNF266S■ 115 19606.00 Type 12 Industrial HNF261J 13 641.00 HNF262J 20 806.00 HNF263J■ 25 1153.00 HNF265J■ 114 3902.00 HNF266J■ 120 6557.00 — — — 15 15 — — — — — 7 1/2 20 30 50 50 HNF361S HNF362SH HNF362S HNF363S HNF364S HNF365S HNF366S HNF367S HNF368S■ HNF361J HNF362JH HNF362J HNF363J HNF364J HNF365J HNF366J HNF367J ■ HNF368J■ 5 10 10 15 15 15 15 15 15 10 20 20 40 60 125 200 250 250 7 1/2 20 20 30 50 50 50 50 50 3-Pole 10 25 40 — — — — — — — 5 10 20 40 50 15 30 50 50 50 480 Volt AC / 600 Volt AC / 250 Volt DC 30 60 60 100 200 400 600 800 1200 13 15 19 24 47 118 120 295 310 2186.00 2537.00 2563.00 5198.00 7078.00 14729.00 21589.00 30951.00 34305.00 ■ Built to order. Allow 2–3 weeks for delivery. Also rated 600V DC. Compact switch (11.1"H, 6.6"W box less cover and handle). Short circuit withstand rating—100,000 RMS sym. amps. 3-12 — — — — — 13 14 19 24 47 119 120 295 310 670.00 930.00 946.00 1338.00 1692.00 4152.00 8150.00 14224.00 18684.00 Use 3-Pole switch for 200A application. for use as service entrance equipment except for 1200 when used on a 480 or 600V grounded wye system. Also rated type 3S / 3R. Suitable Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 20 50 50 75 125 250 400 500 500 10 20 25 40 50 50 50 50 50 30 40 60 100 150 350 500 500 500 5 10 10 20 40 50 50 50 50 — — 30 50 50 50 50 50 50 Indicates oversized enclosure (30A switch in a 60A enclosure or a 60A switch in a 100A enclosure. 600V DC and 600V DC horsepower rating shown requires (2) poles to be connected in series. Discount Schedule HDSS Heavy Duty Safety Switches Type 4/4X & 12 with Viewing Window Selection 30–600A, 3-pole 600V max. in fusible and non-fusible versions in Type 4/4X stainless steel and Type 12 enclosures. All allow viewing of visible blade position. 30–200A also allow viewing of indicating type fuses. ▪ Rugged installer-friendly enclosure design features a gasket flange with continuously welded seams ▪ Tool-free cover latches ▪ Two, three and four point mounting ▪ Metal handle with large insulating grip features a positive stop in both ON and OFF position ▪ Ground lugs provided as standard ▪ Type 12 enclosures are fabricated from galvanized steel and are also rated for 3R/3S outdoor applications ▪ Type 4X stainless steel switches (30–200A) are provided with stainless steel interior parts ▪ The widest range of accessories available including 200% neutrals, gold plated PLC auxiliary contacts and isolated ground kits SAFETY SWITCHES Features 3 Description Maximum Horsepower Ratings System Ampere Catalog Rating Number List Price $ Ship. Weight 240V AC 1-Phase, 2-Wire 480V AC 3-Phase, 3-Wire 3-Phase, 3-Wire 3-Pole, 3-Wire Fusible, Type 12 30 60 100 200 400 600 HF361JW HF362JW HF363JW HF364JW HF365JW HF366JW 1146.00 1169.00 1945.00 2661.00 5867.00 13063.00 HNF361JW HNF362JW HNF363JW HNF364JW HNF365JW 816.00 1093.00 1489.00 1842.00 4299.00 17 22 26 53 166 168 3 10 15 — — — 7 1/2 15 30 60 125 200 15 30 60 125 250 400 HF361SW HF362SW HF363SW HF364SW HF365SW 2828.00 3030.00 5782.00 8171.00 20138.00 14 21 25 51 133 3 10 15 15 15 10 20 40 60 125 20 50 75 125 250 HNF361SW 2333.00 HNF362SW 2720.00 HNF363SW 5349.00 HNF364SW 7228.00 HNF365SW 15917.00 In pounds (lbs). switches are also rated 600V DC. HP ratings listed apply only when time delay fuses are used. Also rated 3S/3R for outdoor use. 200A Maximum Discount Schedule HDSS DC 20 50 75 150 350 500 5 10 20 40 50 50 — 30 50 50 — — 17 23 28 55 168 3 10 15 — 15 15 23 27 54 134 30 60 100 150 350 5 10 20 40 50 — 30 50 50 — 600 Volt AC / 250 Volt DC 7 1/2 15 30 60 125 15 30 60 125 250 3-Pole, 3-Wire Non-Fusible, Type 4X Stainless Steel 30 60 100 200 400 600V DC 600 Volt AC / 250 Volt DC 3-Pole, 3-Wire Fusible, Type 4X Stainless Steel 30 60 100 200 400 250V 600 Volt AC / 250 Volt DC 3-Pole, 3-Wire Non-Fusible, Type 12 30 60 100 200 400 600V AC 3-Phase, 3-Wire 20 50 75 150 350 5 10 20 40 50 — 30 50 50 — 600 Volt AC / 250 Volt DC 3 10 15 15 15 10 20 40 60 125 20 50 75 125 250 30 60 100 150 350 5 10 20 40 50 — 30 50 50 — All switches are suitable for use as service entrance equipment. Use outside poles of 3-pole switch for 2-pole application. 600V DC and 600V DC horsepower rating shown requires (2) poles to be connected in series. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-13 Heavy Duty Safety Switches SAFETY SWITCHES 3 Type VBII 4 & 6-Pole Heavy Duty Safety Switches Selection Application Standards 4 & 6-pole Switches are commonly used as a disconnecting means for two-speed, two-winding motors. Fused switches provide both over current and short circuit protection. Non-fusible switches normally provide a local disconnection means for twospeed motors which are remote from their motor controller. 4-pole switches are also used in 3-phase, 4-wire circuits when a switching neutral is required. All 4 & 6-pole switches are service entrance rated. ▪ UL & CUL listed under file #E4776 ▪ Meets UL98 for enclosed switches ▪ 4 & 6-Pole switches are suitable for use as service entrance ▪ Meets NEMA Standard KS-1 for enclosed switches ▪ Meets NEC wire bending space requirements Description 4 & 6-pole switches are available in 30-200A ratings and in both fusible and non-fusible versions. 4-pole switches are supplied with either Type 1 or Type12/3R enclosures. 6-pole switches are available with either Type 12/3R or Type 4X stainless steel enclosures. Features ▪ Visible blade, double break switching action ▪ Highly visible ON/OFF indication ▪ Defeatable dual cover interlock ▪ Padlock option in OFF position 햲 ▪ All copper current carrying parts ▪ Tangenital knockouts (Type 1, 4-pole switches) HNF663S 4-Pole Type VBII Switches햲 햳햶 System Indoor Type 1 Amp Catalog List Rating Number Price $ 햴 Type 12/3R Industrial Ship Wt. Catalog List Ship Wt. (lbs.) Number Price $ (lbs.) Horsepower Ratings 240V, 2Ø, 4W 240V 3Ø Std. Max. Std. Max. 480V, 3Ø Std. Max. 600V, 3Ø 250V Std. Max. DC Fusible 600 Volt AC, 250 Volt DC — 4-Pole, 4 Fuse햵 30 60 100 200 HF461 HF462 HF463 HF464■ 926.00 1082.00 1786.00 2939.00 36 40 43 88 HF461J HF462J HF463J HF464J■ 1198.00 1321.00 2045.00 3419.00 36 40 43 88 3 71⁄2 15 25 10 20 30 50 3 71⁄2 15 25 71⁄2 15 30 60 5 15 25 50 15 30 60 125 71⁄2 15 30 60 20 50 75 150 5 10 20 40 32 34 36 78 — — — — 10 20 30 50 — — — — 10 20 40 60 — — — — 20 50 75 125 — — — — 30 60 100 150 5 10 20 40 Non-fusible 600 Volt AC, 250 Volt DC — 4-Pole 30 60 100 200 HNF461 HNF462 HNF463■ HNF464■ 881.00 926.00 1716.00 2492.00 32 34 36 78 HNF461J 964.00 HNF462J 1128.00 HNF463J■ 1962.00 HNF464J■ 2964.00 6-Pole Type VBII Switches햲 햳햶 System Type 12/3R Industrial Type 4X Stainless Steel Amp Catalog List Ship Wt. Catalog List Ship Wt. Rating Number Price $ (lbs.) Number Price $ (lbs.) 햴 Horsepower Ratings 240V 3Ø 480V, 3Ø Std. Max. Std. Max. 600V, 3Ø Std. Max. 250V DC Fusible 600 Volt AC, 250 Volt DC — 6-Pole, 6 Fuse햵 30 60 100 200 HF661J HF662J HF663J■ HF664J■ 3594.00 4324.00 5194.00 9599.00 37 41 44 90 HF661S■ HF662S■ HF663S■ HF664S■ 12437.00 13063.00 22191.00 30293.00 37 41 44 90 3 71⁄2 15 25 71⁄2 15 30 60 5 15 25 50 15 30 60 125 71⁄2 15 30 60 20 50 75 150 5 10 20 40 7422.00 8264.00 10120.00 18770.00 33 35 37 80 — — — — 10 20 40 60 — — — — 20 50 75 125 — — — — 30 60 100 150 5 10 20 40 Non-fusible 600 Volt AC, 250 Volt DC — 6-Pole 30 60 100 200 HNF661J HNF662J HNF663J HNF664J 3156.00 3723.00 4479.00 8155.00 33 35 37 80 ■ Built to order. Allow 2–3 weeks for delivery. HNF661S HNF662S HNF663S HNF664S■ 햴 햲 Lugs are aluminum alloy as standard. Optional copper body lugs are available. 햳 All 4 & 6-pole VBII switches are suitable for use as service equipment when a neutral is installed or equipment ground kit is properly connected. 3-14 햵 Dual horsepower ratings: Std. – applies when non-time-delay fuses are installed. Max. – applies when time delay fuses are installed. Fusible switches accept Class H Fuses as the standard. Class R & J fuses can also be installed and increase the rating from 10,000 to 200,000 AIC. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햶 Class J, the load base is moved upward. For Class R fuses, rejection kits are required. Supplied with factory installed ground lugs. Discount Schedule HDSS Heavy Duty Safety Switches Special Application Switches / Interlocked Receptacle Switches Receptacle Safety Switches provide cord connection protection of heavy-duty portable equipment (welders, infrared ovens, batch feeders, portable conveyors, assembly line fixtures and tools, refrigerator trucks, etc.) under load or fault conditions. Type 12 and 4/4X Receptacle Safety Switches are available with 3-phase, 4-wire grounded type Crouse-Hinds Arktite™ 2 receptacle, or Pyle-National pre-wired and mounted with interlock linkage to the switch mechanism. Insertion or removal of the plug is prevented by the interlock linkage while the switch is in the “ON” position. Receptacle prevents operation of switch if incorrect plug is inserted. Type 4/4X Switches are provided with stainless steel interior parts. All receptacle switches are 3-pole, 3-wire plus ground. SAFETY SWITCHES Description 햲 햳 3 Application Selection Crouse-Hinds Interlocked Receptacle Switches 햷 Ampere Rating햶 Type 12 Catalog Number 햸 Type 4/4X Catalog Number List Price $ Shipping Weight Std. Pkg.햵 HF321SCH▲ HF322SCH▲ HF323SCH▲ 7116.00 7437.00 12067.00 23 30 36 APJ3485 & NPJ3485 APJ6485 & NPJ6485 APJ10487 & NPJ10487 HF361SCH HF362SCH HF363SCH▲ 7437.00 7655.00 12803.00 24 30 36 APJ3485 & NPJ3485 APJ6485 & NPJ6485 APJ10487 & NPJ10487 HNF361SCH▲ HNF362SCH HNF363SCH▲ 6857.00 6922.00 11787.00 22 29 35 APJ3485 & NPJ3485 APJ6485 & NPJ6485 APJ10487 & NPJ10487 24 30 36 APJ3485 & NPJ3485 APJ6485 & NPJ6485 APJ10487 & NPJ10487 22 29 35 APJ3485 & NPJ3485 APJ6485 & NPJ6485 APJ10487 & NPJ10487 List Price $ Accepts Crouse-Hinds Arktite 햲 Plug Catalog Number 240V Fusible, 3-Pole, 3-Wire 30 60 100 HF321JCH HF322JCH HF323JCH 2365.00 2440.00 3161.00 600V Fusible, 3-Pole, 3-Wire 30 60 100 HF361JCH HF362JCH HF363JCH 2449.00 2588.00 3392.00 600V Non-Fusible, 3-Pole, 3-Wire 30 60 100 HNF361JCH▲ HNF362JCH HNF363JCH▲ 2153.00 2440.00 2997.00 600V Fusible, 3-Pole, 3-Wire with Viewing Window 30 60 100 HF361JCHW▲ HF362JCHW HF363JCHW▲ 2597.00 2743.00 3547.00 HF361SCHW▲ HF362SCHW HF363SCHW▲ 7593.00 7810.00 12959.00 600V Non-Fusible, 3-Pole, 3-Wire with Viewing Window 30 60 100 HNF361JCHW▲ HNF362JCHW HNF363JCHW▲ 2301.00 2592.00 3151.00 HNF361SCHW▲ HNF362SCHW▲ HNF363SCHW▲ 7005.00 7074.00 11944.00 Pyle-National Interlocked Receptacle Switches 3-Pole, 3-Wire Plus Ground Fusible and Non-Fusible Type 12 Ampere Rating Voltage Catalog Switch Receptacle Rating Number 햷 30 30 600 (F) HF361JPN▲ 600 (N-F) HNF361JPN 60 60 240 (F) HF322JPN▲ 2440.00 — 600 (F) HF362JPN▲ 2588.00 HF362SPN▲ 600 (N-F) HNF362JPN 2440.00 HNF362SPN ▲ Built to order. Allow 6–8 weeks for delivery. 햲 Type 12 Stainless Steel List Catalog Price $ Number 햸 2449.00 HF361SPN▲ 2153.00 HNF361SPN Arktite™ is a registered trademark of the CrouseHinds Company. Plugs are not sold or supplied by Siemens. Discount Schedule HDSS 햳 햴 햵 Shipping Accepts Pyle-National List Weight QuelArc™ 햳햴 Plugs Price $ Std. Pkg.햵 Plug Catalog Number 7437.00 23 JPD-83046 6857.00 21 — 7655.00 6922.00 28 28 27 JPD-116046 Indicates plug with maximum diameter cable bushing. QuelArc™ is a registered trademark of the PyleNational Company. In pounds (lbs.). 햶 햷 햸 Ampere rating of both switch and receptacle. Also rated Type 3R/3S. Enclosure is constructed of Type 304 stainless steel. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-15 Heavy Duty Special Application Safety Switches / Type VBII Non-Metallic Application reinforced enclosure allows a wide range of operating temperatures and is supplied with a continuous memory retaining gasket for a superior seal against entry of water, dust and other contaminants. The excellent insulating properties of fiberglass virtually eliminate problems caused by internal condensation. Siemens Non-Metallic Safety Switches have fiberglass reinforced polyester enclosures which are extremely resistant to a wide range of corrosive atmospheres which can be encountered in waste water treatment plants and certain industrial applications. All switches are load break rated and are provided with an equipment ground kit as standard. Class R fuse clip kits and auxiliary switch kits are also available. SAFETY SWITCHES 3 Description 30-200A, 600V Max, fusible and nonfusible switches are available in Type 4X enclosures. The fiberglass System Ampere Catalog Rating Number Selection Horsepower Rating—3-Phase Ship Weight 240 Volt AC 480 Volt AC 600 Volt AC 250 600 Std.pkg. List Volts Volts (lbs.) Price $ Std. Max. Std. Max. Std. Max. DC DC 3-Pole, 4-Wire, 240 Volt Fusible, Type 4X 030 HF321NX 21 3320.00 3 071⁄2 — 0— — 0— 05 — 060 HF322NX▲ 22 3595.00 71⁄2 15 — 0— — 0— 10 — 3-Pole, 4-Wire, 600 Volt AC Fusible, Type 4X Non-Metallic Features ▪ 30, 60, 100 and 200 Ampere Switches ▪ 600 Volts Fusible ▪ 600 Volts Non-Fusible ▪ Rated 10,000 AIC with Class H Fuses ▪ Rated 200,000 AIC with Class J or R Fuses 030 HF361NX 21 3693.00 03 071⁄2 05 015 071⁄2 020 05 15 060 HF362NX 22 4046.00 071⁄2 15 15 030 15 050 10 30 100 HF363NX▲ 39 7795.00 15 30 25 060 30 075 20 50 200 HF364NX▲ 83 9917.00 25 60 50 125 60 150 40 50 ▪ UL-Listed under File E4776 ▪ Horsepower Rated ▪ Suitable for use as Service Equipment 3-Pole, 3-Wire, 600 AC Volt Non-Fusible, Type 4X 030 HNF361X 20 3127.00 — 071⁄2 — 020 — 030 05 15 060 HNF362X 20 3509.00 — 15 — 050 — 060 10 30 10100 HNF363X▲ 38 6734.00 — 30 — 075 — 100 20 50 200 HNF364X▲ 81 9509.00 — 60 — 125 — 150 40 50 ▪ Quick-make, quick-break mechanism ▪ Visible Blade Construction ▪ Padlock-off handle feature ▪ Field Installable Auxiliary Contacts ▪ Field Replaceable Line and Load Bases ▪ Factory Installed Ground Lug Supplied as Standard ▲ Built to order. Allow 6–8 weeks for delivery. Also used for 240 volt applications. Add “L” to end of catalog number for switches less line & load lugs with mounting hardware for crimp type or copper body lugs. 200A switches are also rated 600V DC max. 600V DC and 600V DC horsepower rating shown requires (2) poles to be connected in series. ▪ Line Terminal Shields ▪ Neutrals Installed as Standard on Fusible Switches 3-16 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule HDSS General and Heavy Duty Safety Switches Accessories Selection HT63 HR612 HN612 All General Duty and Heavy Duty Switches are field convertible to accept Class R Fuse Clip Kits. The kits prevent the installation of Class H and K fuses (one kit required per 3-pole switch). Class R Fuse Clip Kits All 100-600A, General Duty and 1001200A Heavy Duty Switches are field convertible to accept Class T fuses. 400-600A switches are field convertible to accept Class T fuses by moving the load base to a pre-drilled T fuse position. Catalog Number List Price $ Class T Fuse Adapter Kits햲 GSRK321 25.50 30A, 240V Kit (GD only) HR21 83.00 30A, 240V Kit (HD only) Catalog Number HR612 83.00 30A, 600V Kit/60A, 240V Kit HT23 76.00 100A, 240V Kit HR62 83.00 60A, 600V Kit HT63 120.00 100A, 600V Kit HR63 54.00 100A Kit HT24 102.00 200A, 240V Kit HR64 54.00 200A Kit HT64▲ 143.00 200A, 600V Kit HR656 137.00 400A/600A Kit TFAK72 214.00 800A, 240V Kit TFAK75 238.00 800A, 600V Kit TFAK82 543.00 1200A, 240V Kit Description Class J Fusing All 30-600A, 600V and 100-600A,240V fusible Heavy Duty Switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. All 100-600A, 240V fusible General Duty switches can also be field converted to accept Class J fuses. List Price $ SAFETY SWITCHES Class T Fuse Adapter Kits 3 Class R Fuse Clip Kits Description HN264 200% Neutral Kits Neutral Kits Standard Neutral Kits can be field installed in General and Heavy Duty Switches. UL listed 200% Neutrals are available on 100-600A Heavy Duty Switches. They are typically used with non-linear transformers or where increased neutral ampacity/lug capacity is required. 200% Neutral Kits Neutral Kits Switch Ampere Rating 30 GD Kit Catalog Number W410190 30 HD, 60 GD HN612 97.00 60, 100 HD, 100 GD HN623 186.00 200 HN64 186.00 400 & 600 HN656 436.00 800 & 1200 HN678 838.00 List Price $ 71.00 Switch Ampere Rating 100 Kit Catalog List Number Price $ HN263 225.00 Wire Range Line & Load Lugs (Cu/Al) (2) #14-1/0 AWG 200 HN264 352.00 (2) #6 AWG-300 Kcmil 400 HN656 (2) 1/0 AWG-750 Kcmil 436.00 or (4) 1/0 AWG-250 Kcmil 600 HN678 838.00 (4) 1/0 AWG-750 Kcmil ▲ Built to order. Allow 6–8 weeks for delivery. 햲 One kit per pole required. Discount Schedule HDSS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-17 General and Heavy Duty Safety Switches SAFETY SWITCHES 3 Accessories Selection HA261234 HA161234 Auxiliary Contacts Auxiliary Contacts are available only for Heavy Duty Switches. The auxiliary contacts are available in 1 normally open and 1 normally closed or 2 normally open and 2 normally closed configurations. Siemens offers a PLC Auxiliary Switch (30-200A) that has very low resistance for low voltage and current typical in PLC circuits. All auxiliary contacts make after and break before main switch contacts. Auxiliary Contacts Switch Ampere Rating Aux. Switch Catalog List Number Price $ Kit Ampere Rating 125V AC Max. 250V AC Max. Kit Horsepower Rating 28V DC 125V AC Max. Max. 250V AC Max. 28V DC Max. With 1 NO & 1 NC Isolated Contacts 30-200 HA161234 239.00 10 10 — 1/2 3/4 — 400-1200 HA165678 587.00 10 10 — 1/2 3/4 — With 2 NO & 2 NC Isolated Contacts 30-200 HA261234 266.00 10 10 7 1/2 3/4 — 400-1200 HA265678 614.00 10 10 7 1/2 3/4 — Low Current PLC Type with 1 NO & 1 NC Gold Plated Contacts 30-200 HA361234 302.00 10 10 — 1/2 3/4 — 400-1200 HA365678 643.00 10 10 — 1/2 3/4 — Fuse Puller Kits Fuse Puller Kits Fuse Puller Kits are field installable in 30-100A Type VBII Heavy Duty Switches (one kit required per 3-pole switch). Switch Ampere Rating 030 Fuse Puller Kit Catalog Number HP61 List Price $ 21.00 060 HP62▲ 21.00 100 HP63▲ 21.00 HP61 ▲ Built to order. Allow 6–8 weeks for delivery. 3-18 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule HDSS General and Heavy Duty Safety Switches Accessories Selection Copper Lug Kits Heavy duty switches are UL approved to accept field installed copper lug kits. Copper Lug Kits Switch Ampere Rating 30–60 Copper Lug Catalog List Number Price $ Description HLC612 138.00 (9) Lugs/Kit #14-4 AWG Cu 100 HLC63▲ 172.00 (9) Lugs/Kit #14-1/0 AWG Cu 200 HLC64▲ 212.00 (9) Lugs/Kit #6 AWG-300 Kcmil Cu 400–1200 HLC65678 HLC612 37.50 (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu 3 Equipment Ground Kits SAFETY SWITCHES Equipment Ground Lug Kits are available for all General and Heavy Duty Switches. They are field installable in Type 1 and Type 3R Switches and are factory installed as standard in Type 4 / 4X and Type 12 and also in all VBII 4&6-pole Switches. Equipment Ground Kits Switch Ampere Rating 30A GD Catalog Number GSGK60 List Price $ 24.00 Number of Terminals 2 Wire Range Per Terminal (Cu/Al) #14-8 AWG 60–200 GD HG61234 24.00 2 #14-4 AWG 30–200 HD HG61234 24.00 2 #14-4 AWG 400 & 600 HG656 123.00 4 #14-2/0 AWG 800–1200 HG678 239.00 8 #6 AWG-250 Kcmil HG261234 Isolated Ground Kits Isolated Ground Kits are available on 30-600A Heavy Duty Switches. They are normally used on circuits with a high content of computer or other electronic loading which require a ground which is isolated from the building ground and neutral circuits. The kit includes both isolated and grounded terminals as listed below. Isolated Ground Kits Switch Ampere Rating 30–200 Catalog Number HG261234 List Price $ 51.00 Number of Terminals Isolated Grounded 2 2 Wire Range Per Terminal (Cu/Al) #14-4 AWG 400–600 HG2656 156.00 4 #14-2/0 AWG 4 ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule HDSS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-19 General and Heavy Duty Hub and Lug Data Selection SSH150 ECHV300 SAFETY SWITCHES 3 Interchangeable Hubs Conduit hubs are available for Type 3R, 12 and 4 / 4X applications. 30-200A Type 3R Switches are provided with a conduit hub provision and a removable hub plate on their top rainshed. Hubs Conduit Size (inches) Catalog Number List Price $ Used On Type 3R 햲 3/4 1 1 1/4 ECHA075 ECHA100 ECHA125 36.50 36.50 36.50 Cover 3/4 1 1 1/4 1 1/2 2 2 1/2 ECHS000 ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 38.00 39.50 39.50 39.50 39.50 69.00 109.00 2 1/2 3 3 1/2 4 ECHV250 ECHV300 ECHV350 ECHV400 125.00 182.00 274.00 362.00 30A GD Only 60–200A GD 30–200A HD SSH075 SSH100 SSH125 SSH150 SSH200 All Heavy Duty Switches are field convertible for (Crimp) type lugs. When compression lugs are required for 30-100A switches, a neutral barrier kit is required for 1-Phase, 3W or 3-Phase, 4W applications. When compression lugs are required on 400-1200A switches, lug mounting kits are required. Compression Lug Mounting 햴 and Neutral Barrier Kits Switch Ampere Catalog Rating Number 30 HCL612 List Price $ Kit Description 6.40 Neutral Barrier Kit 60 & 100 HCL623 9.70 Neutral Barrier Kit HCL65 1-Pole, Compression 19.00 Lug Mounting Kit HCL65678■ 1-Pole, Compression 22.50 Lug Mounting Kit 800 & 1200 햶 HCL65678■ 1-Pole, Compression 22.50 Lug Mounting Kit 햵 400 & 600 햶 Lugs Type 4/4X햳 3/4 1 1 1/4 1 1/2 2 Compression Lug Mounting & Neutral Barrier Kit 400 400–1200A 46.00 70.00 74.00 102.00 139.00 30–200A Note: 30 thru 200A. Type 3R Switches have removable hub plates on rainshed. 400A and larger Type 3R Switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. 30 & 60A Switches are suitable for use with 60° or 75°C wire. 100–1200A are suitable for use with 75°C rated wire. Switch Ampere Rating 30GD 햲 Hubs suitable for 3R Switches. Also suitable for Type 12 applications. Neutral Barrier kits are required on 30-100A switch only and only with 1-Phase / 3W or 3-Phase / 4W loads. Compression Lugs mounting kits are required on 4001200A switches only. 햵 Provides mounting for a single line or load lug. 햶 Provides mounting for (2) compression lugs per phase on line or load. SL0420 Multiple Padlock Accessory A tamper-proof device to provide for multiple padlocking to meet OSHA or plant requirements. Accepts up to 6 padlocks. Catalog number SL0420. Standard Carton-12. List Price $74.00. Kirk-Key Interlocks Kirk-Key Interlocks can be factoryinstalled only on Type VBII Heavy Duty and Double Throw Safety Switches. Interlocks are used to prevent the operator from making an unauthorized operation. The interlock system is a simple method of applying key interlocks to safety switches so as to require operation in a predetermined sequence. List Price $1675.00. Before consulting the factory, the following information is required: ▪ User name and address ▪ Key number from lock assemblies on any existing locks to be interlocked with ▪ Complete locking scheme Consult factory for delivery. Wire Ranges (Line, Load and Standard Neutral) 햴 Lug Wire Range #14-8 AWG (Cu/AI)햷 #14-8 AWG (Cu/Al) #14-6 AWG (Cu/AI) #14-2 AWG (Cu/Al) 60햹햻 #14-3 AWG (Cu/AI) #14-2 AWG (Cu/Al) 100햽 #14-1/0 AWG (Cu/Al) #14-1/0 AWG (Cu/Al) 200햺 #6 AWG-250 Kcmil (Cu/Al) #6 AWG-300 Kcmil (Cu/Al) 400햸 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-250 Kcmil (Cu/Al) (1) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-250 Kcmil (Cu/Al) 600햸 (2) 1/0 AWG-750 Kcmil (Cu/Al) or (4) 1/0 -250 Kcmil (Cu/Al) (2) 1/0 AWG-750 Kcmil (Cu/Al) or (4) 1/0 AWG-250 Kcmil (Cu/Al) 800 (3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load or (6) 1/0 AWG-250 Kcmil (Cu/Al) (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load or (6) 1/0 AWG-250 Kcmil (Cu/Al) (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (4) 3/0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (4) 1/0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral 1200 햳 Wire Range with Wire Bending Space Per NEC Requirements 30HD ■ Built to order. Allow 2-3 weeks for delivery. 3-20 ECHS200 햷 Line lugs are UL approved to accept #14-6 CU/Al cable. Max. wire size for height reduced switches is 500 kcmil (Cu/Al). 햹 All but 60A GD & Compact HD NF switches are also UL approved for #2 Cu/Al conductors. 햸 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햺 All 200A Heavy Duty Switches have a wire range & wire bending space for (1) #6-300 Kcmil (Cu/Al). Also for 30A oversized heavy duty switches. 햽 Also for 60A oversized heavy duty switches. 햻 Discount Schedule HDSS & RESI General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights Height Width Catalog Number Box A GF221N GF221NR GF222N GF222NR GF223N 7.97 8.07 14.26 14.39 21.95 8.13 — 15.45 — 23.15 — 8.16 — 15.76 — 5.50 5.16 6.64 6.64 9.64 5.94 5.94 8.70 8.70 11.70 3.00 3.13 5.05 5.05 5.05 5.88 5.88 8.63 8.63 8.63 S1 S3 S6 S8 S10 GF223NR GF224N GF224NR GF225N GF225NH GF225NR GF225NRH 21.95 29.90 29.90 56.00 45.25 56.07 45.31 — 31.07 — 56.57 45.82 — — 23.46 — 31.42 — — 57.19 46.44 9.64 14.62 14.61 24.65 24.65 24.65 24.65 11.67 16.68 16.68 26.21 26.21 26.70 26.70 5.05 6.36 6.36 9.23 9.23 9.23 9.23 8.70 10.92 10.92 14.68 14.68 14.68 14.68 S11 S12 S13 S14 S14 S15 S15 24 47 48 153 128 157 130 GF226N GF226NH GF226NR GF226NRH GF321N GF321NR GF322N 56.00 45.25 56.07 45.31 7.97 8.07 14.26 56.57 45.82 — — 8.19 — 15.45 — — 57.19 46.44 — 8.16 — 24.64 24.65 24.64 24.65 7.19 7.19 6.64 26.21 26.21 26.70 26.70 7.69 8.16 8.70 9.23 9.23 9.23 9.23 3.00 3.13 5.05 14.68 14.68 14.68 14.68 5.88 5.88 8.63 S14 S14 S15 S15 S2 S4 S6 155 133 159 135 24 (5) 24 (5) 15 GF322NR GF323N GF323NR GF324N GF324NR 14.39 21.95 21.95 29.90 29.90 — 23.15 — 31.07 — 15.76 — 23.46 — 31.42 6.64 9.64 9.64 14.62 14.61 8.70 11.70 11.67 16.68 16.68 5.05 5.05 5.05 6.36 6.36 8.63 8.63 8.70 10.92 10.92 S8 S10 S11 S12 S13 GF325N GF325NH GF325NR GF325NRH GF326N GF326NH GF326NR GF326NRH GNF321 56.00 45.25 56.07 45.31 56.00 45.25 56.07 45.31 7.97 56.57 45.82 — — 56.57 45.82 — — 8.19 — — 57.19 46.44 — — 57.19 46.44 — 24.65 24.65 24.65 24.65 24.65 24.65 24.65 24.65 7.19 26.21 26.21 26.70 26.70 26.21 26.21 26.70 26.70 7.69 9.23 9.23 9.23 9.23 9.23 9.23 9.23 9.23 3.00 14.68 14.68 14.68 14.68 14.68 14.68 14.68 14.68 5.88 S14 S14 S15 S15 S14 S14 S15 S15 S2 158 136 162 138 161 138 165 141 24 (5) GNF321R GNF322 GNF322R GNF323 GNF323R 8.07 11.11 11.11 21.95 21.95 — 12.31 — 23.15 — 8.16 — 12.62 — 23.46 7.19 6.64 6.64 9.64 9.64 7.69 8.71 8.71 11.70 11.67 3.13 5.05 5.05 5.05 5.05 5.88 8.61 8.61 8.63 8.70 S4 S7 S9 S10 S11 24 (5) 12 13 23 24 GNF324 GNF324R GNF325 GNF326 HF221J 29.90 29.90 44.00 44.00 14.27 31.07 — 44.57 44.57 17.33 — 31.42 — — — 14.62 14.61 24.65 24.65 6.65 16.68 16.68 26.21 26.21 9.02 6.36 6.36 9.23 9.23 5.32 10.92 10.92 14.68 14.68 10.46 S12 S13 S14 S14 — 46 47 114 116 13 HF221N HF221NR HF221S HF222J HF222N 14.26 14.39 14.27 16.22 16.26 15.45 — 17.33 19.31 17.46 — 15.77 — — — 6.64 6.64 6.65 9.17 9.15 9.01 9.01 9.02 11.47 11.53 5.05 5.05 5.32 5.33 5.05 10.17 10.17 10.46 10.46 10.17 S6 S8 — — S16 12 13 13 19 18 HF222NR HF222S HF223J HF223N HF223NR 16.26 16.22 21.96 21.95 21.95 — 19.31 23.16 23.15 — 17.77 — — — 23.46 9.16 9.17 9.65 9.64 9.64 11.53 11.47 12.02 12.01 11.97 5.05 5.33 5.34 5.05 5.05 10.17 10.46 10.46 10.17 10.17 S17 — — S10 S11 19 19 24 23 24 Box F With Handle G Knockout Diagram 햲 Shipping Weight (lbs.) 35 (10) 35 (10) 14 14 23 SAFETY SWITCHES 햲 Box D With Handle E 3 *For inches / millimeters conversion, multiply inches by 25.4. With Rain Shed C Depth With Door B 15 25 25 49 50 Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-21 General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights SAFETY SWITCHES 3 Height Width Depth Catalog Number Box A With Door B With Handle G Knockout Diagram HF223S HF224J HF224N HF224NR HF224S 21.96 29.96 29.90 29.90 29.96 23.16 31.07 31.07 — 31.07 — — — 31.42 — 9.65 14.62 14.62 14.61 14.62 12.02 16.95 16.98 16.99 16.95 5.34 6.63 6.36 6.36 6.63 10.46 12.58 12.33 12.33 12.58 — — S12 S13 — 24 48 47 48 48 HF225N HF225NH HF225NR HF225NRH HF226N HF226NH HF226NR HF226NRH 56.00 45.25 56.07 45.31 56.00 45.25 56.07 45.31 56.57 45.82 — — 56.57 45.82 — — — — 57.19 46.44 — — 57.19 46.44 24.65 24.65 24.65 24.65 24.65 24.65 24.65 24.65 26.21 26.21 26.70 26.70 26.21 26.21 26.70 26.70 9.23 9.23 9.23 9.23 9.23 9.23 9.23 9.23 14.68 14.68 14.68 14.68 14.68 14.68 14.68 14.68 S14 S14 S15 S15 S14 S14 S15 S15 153 129 162 131 155 133 159 135 HF227N HF227NR HF228N HF228NR 66.25 66.25 66.25 66.25 66.82 — 66.82 — — 67.36 — 67.36 38.40 38.40 38.40 38.40 39.96 39.96 39.96 39.96 9.24 9.24 9.24 9.24 14.68 14.68 14.68 14.68 — — — — 360 362 362 364 HF265 HF265J HF265R HF265S 56.00 56.14 56.07 56.14 56.57 56.57 — 56.57 — — 57.19 — 24.65 24.82 24.65 24.82 26.21 26.44 26.70 26.44 9.23 9.19 9.23 9.19 14.68 14.64 14.68 14.64 S14 — S15 — 149 155 152 153 HF266 HF266J HF266R HF266S 56.00 56.14 56.07 56.14 56.57 56.57 — 56.57 — — 57.19 — 24.65 24.82 24.65 24.82 26.21 26.44 26.70 26.44 9.23 9.19 9.23 9.19 14.68 14.68 14.68 14.68 S14 — S15 — 155 156 155 161 HF321J HF321N HF321NR HF321S HF322J HF322N 14.27 14.26 14.39 14.27 16.27 16.26 17.33 15.45 — 17.33 19.31 17.46 — — 15.77 — — — 6.65 6.64 6.64 6.65 9.17 9.15 9.02 9.01 9.01 9.02 11.47 11.53 5.32 5.05 5.05 5.32 5.33 5.05 10.46 10.17 10.17 10.46 10.46 10.17 — S6 S8 — — S16 14 14 15 14 20 19 HF322NR HF322S HF323J HF323N HF323NR 16.26 16.27 21.96 21.95 21.95 — 19.31 23.16 23.15 — 17.77 — — — 23.46 9.16 9.17 9.65 9.64 9.64 11.53 11.47 12.02 12.01 11.97 5.05 5.33 5.34 5.05 5.05 10.17 10.46 10.46 10.17 10.17 S17 — — S10 S11 20 20 25 25 26 HF323S HF324J HF324N HF324NR HF324S 21.96 29.96 29.90 29.90 21.96 23.16 31.07 31.07 — 31.07 — — — 31.42 — 9.65 14.62 14.62 14.61 14.62 12.02 16.95 16.98 16.99 16.95 5.34 6.63 6.36 6.36 6.63 10.46 12.58 12.33 12.33 12.58 — — S12 S13 — 25 49 49 50 49 HF325J HF325N HF325NH HF325NR HF325NRH HF325S HF326J 56.14 56.00 45.25 56.07 45.31 56.14 56.14 56.57 56.57 45.82 — — 56.57 56.57 — — — 57.19 46.44 — — 24.82 24.65 24.65 24.65 24.65 24.82 24.82 26.44 26.21 26.21 26.70 26.70 26.44 26.44 9.19 9.23 9.23 9.23 9.23 9.19 9.19 14.64 14.68 14.68 14.68 14.68 14.64 14.64 — S14 S14 S15 S15 — — 160 158 137 162 138 158 161 HF326N HF326NH HF326NR HF326NRH HF326S HF327J HF327N 56.00 45.25 56.07 45.31 56.14 66.25 66.25 56.57 45.82 — — 56.57 66.82 66.82 — — 57.19 46.44 — — — 24.64 24.65 24.64 24.65 24.82 38.40 38.40 26.21 26.21 26.70 26.70 26.44 39.96 39.96 9.23 9.23 9.23 9.23 9.19 9.24 9.24 14.68 14.68 14.68 14.68 14.64 14.68 14.68 S14 S14 S15 S15 — — — 161 139 165 142 161 367 380 HF327NR HF327S HF328N HF328NR HF361 HF361J, JW 66.25 66.25 66.25 66.25 14.26 14.27 — 66.82 66.82 — 15.45 17.33 67.36 — — 67.36 — — 38.40 38.40 38.40 38.40 6.64 6.65 40.25 39.96 39.96 40.25 9.01 9.02 9.24 9.24 9.24 9.24 5.05 5.32 14.68 14.68 14.68 14.68 10.17 10.46 — — — — S6 — 383 367 382 385 14 14 HF361L HF361N HF361NR HF361R HF361RL HF361S, SW HF362 16.26 14.26 14.39 14.39 16.26 14.27 16.26 17.46 15.45 — — — 17.33 17.46 — — 15.77 15.77 17.77 — — 9.15 6.64 6.64 6.64 9.16 6.65 9.15 11.53 9.01 9.01 9.01 11.53 9.02 11.53 5.05 5.05 5.05 5.05 5.05 5.32 5.05 10.17 10.17 10.17 10.17 10.17 10.46 10.17 S16 S6 S8 S8 S17 — S16 19 14 15 15 20 15 19 *For inches / millimeters conversion, multiply inches by 25.4. 3-22 With Rain Shed C Box D With Handle E 햲 Box F Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햲 Shipping Weight (lbs.) General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights Height Width With Rain Shed C Depth With Handle G Knockout Diagram HF362J, JW HF362N HF362NR HF362R HF362RL HF362S, SW 16.27 16.26 16.26 16.26 21.95 16.27 19.31 17.46 — — — 19.31 — — 17.77 17.77 23.46 — 9.17 9.15 9.16 9.16 9.64 9.17 11.47 11.53 11.53 11.53 11.97 11.47 5.33 5.05 5.05 5.05 5.05 5.33 10.46 10.17 10.17 10.17 10.17 10.46 — S16 S17 S17 S11 — 20 19 20 20 25 20 HF363 HF363J, JW HF363N HF363NR HF363R 21.95 21.96 21.95 21.95 21.95 23.15 23.16 23.15 — — — — — 23.46 23.46 9.64 9.65 9.64 9.64 9.64 12.01 12.02 12.01 11.97 11.97 5.05 5.34 5.05 5.05 5.05 10.17 10.46 10.17 10.17 10.17 S10 — S10 S11 S11 24 25 25 26 25 HF363S HF364 HF364J, JW HF364N HF364NR 21.96 29.90 29.96 29.90 29.90 23.16 31.07 31.07 31.07 — — — — — 31.42 9.65 14.62 14.62 14.62 14.61 12.02 16.98 16.95 16.98 16.99 5.34 6.36 6.63 6.36 6.36 10.46 12.33 12.58 12.33 12.33 — S12 — S12 S13 25 48 49 49 48 HF364R HF364S, SW HF365 HF365H HF365J, JW HF365N 29.90 29.96 56.00 45.25 56.14 56.00 — 31.07 56.57 45.82 56.57 56.57 31.42 — — — — — 14.61 14.62 24.65 24.65 24.82 24.65 16.99 16.95 26.21 26.21 26.44 26.21 6.36 6.63 9.23 9.23 9.19 9.23 12.33 12.58 14.68 14.68 14.64 14.68 S13 — S14 S14 — S14 49 49 154 136 160 158 HF365NR HF365R HF365RH HF365S, SW HF366 HF366H HF366J, JW 56.07 56.07 45.25 56.14 56.00 45.25 56.14 — — 45.82 56.57 56.57 45.82 56.57 57.19 57.19 — — — — — 24.65 24.65 24.65 24.82 24.64 24.65 24.82 26.70 26.70 26.70 26.44 26.21 26.21 26.44 9.23 9.23 9.23 9.19 9.23 9.23 9.19 14.68 14.68 14.68 14.64 14.68 14.68 14.64 S15 S15 S15 — S14 S14 — 162 157 137 158 157 138 161 HF366N HF366NR HF366R HF366RH HF366S 56.00 56.07 56.07 45.25 56.14 56.57 — — 45.82 56.57 — 57.19 57.19 — — 24.65 24.65 24.65 24.65 24.82 26.21 26.70 26.70 26.70 26.44 9.23 9.23 9.23 9.23 9.19 14.68 14.68 14.68 14.68 14.64 S14 S15 S15 S15 — 161 165 161 141 161 HF367 HF367J HF367N HF367NR HF367R 66.25 66.25 66.25 66.25 66.25 66.82 66.82 66.82 — — — — — 67.36 67.36 38.40 38.40 38.40 38.40 38.40 39.96 39.96 39.96 40.25 40.25 9.24 9.24 9.24 9.24 9.24 14.68 14.68 14.68 14.68 14.68 — — — — — 380 380 382 386 382 HF367S HF368, J, S HF368N HF368NR HF368R 66.25 66.25 66.25 66.25 66.25 66.82 66.82 66.82 — — — — — 67.36 67.36 38.40 38.40 38.40 38.40 38.40 39.96 39.96 39.96 40.25 40.25 9.24 9.24 9.24 9.24 9.24 14.68 14.68 14.68 14.68 14.68 — — — — — 380 383 385 388 385 HNF265 HNF265J HNF265R HNF265S 44.00 44.14 44.07 44.14 44.57 44.57 — 44.57 — — 45.19 — 24.65 24.82 24.65 24.82 26.21 26.44 26.70 26.44 9.23 9.19 9.23 9.19 14.68 14.64 14.68 14.64 S14 — S15 — 109 119 118 118 HNF266 HNF266J HNF266R HNF266S 44.00 44.14 44.07 44.14 44.57 44.57 — 44.57 — — 45.19 — 24.65 24.82 24.64 24.82 26.21 26.44 26.70 26.44 9.23 9.19 9.23 9.19 14.68 14.64 14.68 14.64 S14 — S15 — 111 115 120 115 HNF361 HNF361J, JW HNF361R HNF361RL HNF361S, SW HNF362 HNF362J, JW 11.11 11.12 11.11 16.26 11.12 16.26 16.27 12.31 14.14 — — 14.14 17.46 17.46 — — 12.63 17.77 — — — 6.64 6.65 6.64 9.16 6.65 9.15 9.17 9.01 9.02 9.01 11.53 9.02 11.53 11.47 5.05 5.56 5.05 5.05 5.56 5.05 5.33 10.17 10.46 10.17 10.17 10.46 10.17 10.46 S7 — S9 S17 — S16 — 12 13 13 20 13 18 19 HNF362R HNF362RL HNF362S, SW HNF363 HNF363J, JW HNF363R 16.26 21.95 16.27 21.95 21.96 21.95 — — 17.46 23.15 23.16 — 17.77 23.46 — — — 23.46 9.16 9.64 9.17 9.64 9.65 9.64 11.53 11.97 11.47 12.01 12.02 11.97 5.05 5.05 5.33 5.05 5.34 5.05 10.17 10.17 10.46 10.17 10.46 10.17 S17 S11 — S10 — S11 19 24 19 23 24 24 HNF363S, SW HNF364 HNF364J, JW HNF364R HNF364S, SW 21.96 29.90 29.96 29.90 29.96 23.16 31.07 31.07 — 31.07 — — — 31.42 — 9.65 14.62 14.62 14.61 14.62 12.02 16.98 16.95 16.99 16.95 5.34 6.36 6.63 6.36 6.63 10.46 12.33 12.58 12.33 12.58 — S12 — S13 — 24 46 47 47 47 *For inches / millimeters conversion, multiply inches by 25.4. 햲 Box F 햲 Shipping Weight (lbs.) SAFETY SWITCHES Box A Box D With Handle E 3 Catalog Number With Door B Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-23 General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights SAFETY SWITCHES 3 Height Width Depth Catalog Number Box A With Door B With Rain Shed C Box D With Handle E With Handle G Knockout Diagram Shipping Weight (lbs.) HNF365 HNF365J, JW HNF365R HNF365S, SW HNF366 44.00 44.14 44.07 44.14 44.00 44.57 44.57 — 44.57 44.57 — — 45.19 — — 24.65 24.82 24.65 24.82 24.65 26.21 26.44 26.95 26.44 26.21 9.23 9.19 9.23 9.19 9.23 14.68 14.64 14.68 14.64 14.68 S14 — S15 — S14 114 114 118 118 116 HNF366J, S HNF366R HNF367, J 44.14 44.07 54.25 44.57 — 54.82 — 45.19 — 24.82 24.65 38.40 26.44 26.95 39.96 9.19 9.23 9.24 14.64 14.68 14.68 — S15 — 115 120 302 HNF367R HNF367S HNF368, J, S HNF368R 54.25 54.25 54.25 54.25 — 54.82 54.82 54.82 55.36 — — — 38.40 38.40 38.40 38.40 40.25 39.96 39.96 40.25 9.24 9.24 9.24 9.24 14.68 14.68 14.68 14.68 — — — — 304 302 305 307 LF111N LF111NR 7.97 8.07 8.13 — — 8.16 5.50 5.16 5.94 5.94 3.00 3.13 5.38 5.38 S2 S3 35 (10) 35 (10) LF211N LF211NR LNF222R 7.97 8.07 8.07 8.13 — — — 8.16 8.16 5.50 5.16 5.16 5.94 5.94 5.94 3.00 3.13 3.13 5.38 5.38 5.38 S1 S3 S5 35 (10) 35 (10) 35 (10) Type 1 or 3R 60-200A GD, 30-200A HD Type VBII Type 1 or 3R 30A GD E B or C A D E 햲 Type 4/4X or 12 30-200A HD Type VBII E G B or C A G B or C A F G E E G B or C A F *For inches / millimeters conversion, multiply inches by 25.4. D Type 4/4X or 12 400-1200A HD Type VBII G B or C D F D Type 1 or 3R 400-1200A Type VBII (GD & HD) 3-24 Box F A D 햲 F Knocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog F General and Heavy Duty Safety Switches Knockout Diagrams Type 1 & 3R Enclosures Removable plate covering HA Type Hub opening (Max. 1.25 Conduit) S1 Embossed .25 in. mounting holes (4 places) S3 S2 4 K.O.'s for Conduit 0.5-0.75 in. 2 K.O.'s for Conduit 0.5-0.75 in. 10 K.O.'s for Conduit 0.5-0.75-1 in. 2 K.O.'s for Conduit 0.5-0.75 in. 3 7 K.O.'s for Conduit 0.5-0.75-1 in. 3 K.O.'s for Conduit 0.5-0.75-1 in. 4 K.O.'s for Conduit 0.75, 1 in. S5 Embossed .25 in. mounting holes (3 places) Embossed .25 in. mounting holes (3 places) S6 2 K.O.'s for Conduit 0.5-0.75 in. 2 K.O.'s for Conduit 0.5-0.75 in. 3 K.O.'s for Conduit 0.5-0.75-1 in. 4 K.O.'s for Conduit 0.5-0.75-1 in. 8 K.O.'s for Conduit 0.50, 0.75, 1 in. 2 0.25 dia. K.O's Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) 4 K.O.'s for Conduit 0.75, 1 in. S7 S8 S9 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in. 1 0.25 dia. K.O. 2 0.25 dia. K.O's 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in. 1 0.25 dia. K.O. Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S12 S10 S11 1 0.25 dia. K.O. 2 0.25 dia. K.O. 4 K.O.'s for Conduit 0.75, 1, 1.25, 1.50 in. 10 K.O.'s for Conduit 1, 1.25, 1.50, 2 in. 1 0.88 dia. K.O. 5 K.O.'s for Conduit 1, 1.25, 1.50, 2 in. 2 K.O.'s for Conduit 0.75, 1, 1.25, 1.50 in. 1 0.88 dia. K.O. 1 0.25 dia. K.O. 1 0.88 dia. K.O. 14 K.O.'s for Conduit 1.25, 1.50, 2.00, 2.50 in. *For inches / millimeters conversion, multiply inches by 25.4. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-25 SAFETY SWITCHES 10 K.O.'s For Conduit 0.50, 0.75, 1 in. Removable plate covering HA Type Hub opening (Max. 1.25 Conduit) S4 Embossed .25 in. mounting holes (3 places) Embossed .25 in. mounting holes (4 places) General and Heavy Duty Safety Switches Knockout Diagrams Type 1 & 3R Enclosures Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S14 S15 S13 1, 0.25, dia. K.O 8 K.O.'s for Conduit 2.00, 2.50, 3.00, 3.50 in. 4 0.50, 0.75 dia. K.O.'s SAFETY SWITCHES 3 7 K.O.'s for Conduit 1.25, 1.50, 2.00, 2.50 in. 1 0.88 dia K.O. Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S16 S17 2 0.25 dia. K.O. 1 0.25 dia. K.O. 14 K.O.'s for Conduit 0.50, 0.75, 1, 1.25 in. 1 0.88 dia. K.O. 7 K.O.'s for Conduit 0.50, 0.75, 1, 1.25 in. 1 0.88 dia. K.O. *For inches / millimeters conversion, multiply inches by 25.4. 3-26 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4 K.O.'s for Conduit 2.00, 2.50, 3.00, 3.50 in. 2 0.50, 0.75 dia. K.O.'s Special Application Safety Switches Dimension Drawings Non-Metallic Dimensions W Non-Metallic 4 X 0.50 (12.70) C F G H A E 3 D J SAFETY SWITCHES B Dimensions (Inches) Non-Metallic Catalog Number H W D A B C E F G J HF321NX HF322NX HF361NX햲 HF362NX햲 HF363NX햲 HF364NX햲 18.75 18.75 18.75 18.75 26.95 33.41 12.11 12.11 12.11 12.11 14.87 27.47 10.25 10.25 10.25 10.25 13.25 13.19 16.59 16.59 16.59 16.59 24.84 31.31 10.97 10.97 10.97 10.97 13.72 26.31 7.00 7.00 7.00 7.00 6.25 18.50 17.50 17.50 17.50 17.50 25.75 32.25 1.98 1.98 1.98 1.98 3.75 3.91 .46 .46 .46 .46 .46 .47 9.20 9.20 9.20 9.20 12.15 12.10 HNF361X햲 HNF362X햲 HNF363X햲 HNF364X햲 18.75 18.75 26.95 33.41 12.11 12.11 14.87 27.47 10.25 10.25 13.25 13.19 16.59 16.59 24.84 31.31 10.97 10.97 13.72 26.31 7.00 7.00 6.25 18.50 17.50 17.50 25.75 32.25 1.98 1.98 3.75 3.91 .46 .46 .46 .47 9.20 9.20 12.15 12.10 VBII Interlocked Receptacle Switches Ampere Rating B Dimensions (Inches) A B C D E F 6.22 6.34 6.80 1.52 1.52 1.52 6.1 6.4 6.5 6.0 7.4 7.6 6.22 6.34 6.80 1.52 1.52 1.52 6.1 6.4 6.5 6.0 7.4 7.6 1.52 1.52 3.5 5.0 3.0 4.5 D E G Cr-H Type Fusible (240 & 600V) 30 60 100 14.27 16.27 21.96 7.42 9.17 9.65 9.02 11.47 12.02 A Cr-H Type Non-Fusible (600V max.) 30 60 100 14.27 16.27 21.96 7.42 9.17 9.65 9.02 11.47 12.02 Pyle-National Type Fusible (240 & 600V) 30 60 14.27 16.27 7.42 9.17 9.02 11.47 6.22 6.34 G Pyle-National Type Non-Fusible (600V max.) 30 60 14.27 16.27 7.42 9.17 9.02햲 11.47햲 *For inches / millimeters conversion, multiply inches by 25.4. 6.22 6.34 1.52 1.52 햲 3.5 5.0 3.0 4.5 C F Dimensions also apply to “L” suffix switches (less lugs). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-27 Special Application Safety Switches Dimension Drawings 4-Pole & 6-Pole Dimensions 4 & 6-Pole Safety Switch Dimensions – Inches (mm) Mounting Enclosure Catalog Number A B C Figure 1, 4-Pole Fusible and Non-fusible, Type 1 SAFETY SWITCHES 3 HNF461 HF461 HNF462 HF462 HNF463 HF463 HNF464 HF464 24.50 29.12 24.88 33.53 27.62 36.44 36.00 49.48 (622) (740) (632) (852) (702) (926) (914) (1257) 9.53 (242) 9.53 (242) 11.50 (292) 11.50 (292) 12.18 (309) 12.18 (309) 19.12 (486) 19.12 (486) 6.09 6.09 6.09 6.09 6.09 6.09 6.42 6.42 D (155) (155) (155) (155) (155) (155) (163) (163) 19.00 23.50 19.00 27.50 19.36 28.11 30.88 45.50 (483) (597) (483) (699) (492) (714) (784) (1130) E F 6.75 (171) 6.75 (171) 9.38 (238) 9.38 (238) 8.00 (203) 8.00 (203) 15.00 (381) 15.00 (381) 0.268 (7) 0.268 (7) 0.268 (7) 0.268 (7) 0.268 (7) 0.268 (7) 0.44 (11) 0.44 (11) Figure 2, 4 & 6-Pole Fusible Type 12/3R and 4X HF461J, HF661S HF462J, HF662S HF463J, HF663S HF464J, HF664S HF661J, 29.50 (622) 9.53 (242) 6.48 (165) 31.65 (804) 5.47 (139) 0.27 (7) HF662J, 33.53 (852) 11.50 (292) 6.48 (165) 35.69 (907) 8.00 (203) 0.27 (7) HF663J, 36.44 (926) 12.18 (309) 6.48 (165) 38.67 (982) 8.47 (215) 0.27 (7) HF664J, 49.48 (1257) 19.12 (486) 6.78 (172) 51.64 (1312) 13.44 (341) 0.33 (8) Figure 2, 4 & 6-Pole Non-fusible Type 12/3R and 4X HNF461J, HNF661S HNF462J, HNF662S HNF463J, HNF663S HNF464J, HNF664S HNF661J, 24.50 (622) 9.53 (242) 6.48 (165) 26.65 (667) 5.47 (139) 0.27 (7) HNF662J, 24.88 (632) 11.50 (292) 6.48 (165) 27.03 (687) 8.00 (203) 0.27 (7) HNF663J, 27.54 (700) 12.18 (309) 6.48 (165) 29.77 (756) 8.47 (215) 0.27 (7) HNF664J, 36.00 (914) 19.12 (486) 6.78 (172) 38.16 (969) 13.44 (341) 0.33 (8) Figure 1: Type 1 3-28 Figure 2 : Type 12/3R and 4X Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Special Application Safety Switches Dimension Drawings Double Throw Selection Description fusible switches so that the fuses are on the load side of the switching mechanism. Double throw switches are intended to transfer loads from one power source to another. All 2 & 3-pole double throw switches are suitable for use as service equipment. All are UL Listed and both horsepower and load break rated. Switches are rated for use on systems up to 10,000A when protected with Class H fuses or 100,000A when protected with Class R or Class T fuses. They can also be used to connect a single source of power to either of two loads. In this application it is necessary to field modify A cover interlock is provided on all ampere ratings. The operating handle may be padlocked in the off position. Fuse Capabilities of Fusible DTF Switches Amp Rating Fuse Type H R T J 30 & 60A, 240V Std Yes (kit) No No 30 & 60A, 600V Std Yes (kit) No Yes 100 & 200A Std Yes (kit) Yes (kit) 400 & 600A (DTF) No No Yes Yes Std 3 Double Throw Switches System Voltage Amps Catalog Number Type 12/3R — Industrial Type 4X — Stainless Steel Catalog Number Catalog Number Catalog Number DTF224R List Price $ List Price $ List Price $ Heavy Duty Fusible (30-200A) with Class H fuse spacings 240 Volt AC or 250 Volt DC 2 200 DTF224▲ 4043.00 5633.00 — — — — 3 30 60 100 200 400 600 DTF321 DTF322 DTF323▲ DTF324 DTF325 DTF326▲ 1180.00 2119.00 3551.00 5233.00 12487.00 13503.00 DTF321R▲ DTF322R▲ DTF323R DTF324R FR325DTK▲ FR326DTK▲ 1733.00 2844.00 4020.00 6866.00 14403.00 15944.00 — — — — — — — — — — — — — — — — — — — — — — — — 30 60 100 200 400 DTF361 DTF362▲ DTF363 DTF364 DTF365 2265.00 2376.00 4177.00 6143.00 12778.00 — — DTF363R DTF364R FR355DTK▲ — — 5408.00 7991.00 14650.00 — — — — — — — — — — — — F353SSDTK▲ F354SSDTK▲ F355SSDTK▲ 2 30 60 100 200 400 DTNF221 DTNF222 DTNF223 DTNF224 DTNF225 672.00 1062.00 1485.00 1953.00 5599.00 — — — DTNF224R DTNF225R — — — 2557.00 8618.00 — — — — — — — — — — — — — — — — — — — — 3 30 60 100 200 400 600 800 DTNF321 DTNF322 DTNF323 DTNF324 DTNF325 DTNF326 DTNF327▲ 795.00 1271.00 1924.00 2804.00 7859.00 10523.00 16275.00 — — DTNF323R DTNF324R — — — — — 2210.00 3556.00 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 30 60 100 200 400 600 800 1200 DTNF361 DTNF362 DTNF363 DTNF364 DTNF365 DTNF366 DTNF367 DTNF368▲ 893.00 1236.00 2053.00 3003.00 8033.00 11760.00 18092.00 24760.00 DTNF361R DTNF362R DTNF363R DTNF364R DTNF365R DTNF366R DTNF367R DTNF368R 1538.00 2041.00 3567.00 5040.00 13137.00 16589.00 19178.00 26601.00 DTNF361J DTNF362J DTNF363J DTNF364J▲ NF355HDTK — — — — — — NF454DTK NF455DTK▲ NF456DTK▲ NF457DTK▲ — — — 5192.00 13378.00 17588.00 44586.00 NFR451DTK ▲ NFR452DTK ▲ NFR453DTK ▲ NFR454DTK ▲ NFR455DTK▲ NFR456DTK▲ NFR457DTK▲ 4106.00 4373.00 6489.00 8758.00 18123.00 22291.00 54653.00 — — — — — — — 600 Volt AC, 3 250 Volt DC Heavy Duty Non-Fusible 240 Volt AC or 250 Volt DC 3 600 Volt AC, or 250 Volt DC 4 30 60 100 200 400 600 800 General Duty Non-Fusible 240 Volt AC — — 14502.00 17873.00 29061.00 Type 3R — Outdoor Less Neutral Type 3R — Outdoor With Neutral 1850.00 2517.00 3297.00 7125.00 13283.00 — — — DTNF361S DTNF362S DTNF363S DTNF364S NF355SSDTK — — — 4624.00 6196.00 9254.00 11220.00 23311.00 — — — — — — — — — — — — — NF454SSDTK▲ — — — — — — 19858.00 — — — 2 100 200 DTGNF223R DTGNF224R 1150.00 1850.00 DTGNF223NR DTGNF224NR 1349.00 2202.00 — — — — — — — — 3 100 200 DTGNF323R DTGNF324R 1678.00 2097.00 DTGNF323NR DTGNF324NR 1890.00 2432.00 — — — — — — — — ▲ Built to order. Allow 3–4 weeks for delivery. Use HS Type hubs for 30–200A switches. 400A and larger switches do not have hub provisions. All Heavy Duty double throw switches with a catalog Discount Schedule HDSS number starting with “DT” are rated 200,000 AIC max. when protected by Class R, J or T fuses. Fuse ampere rating must not exceed switch ampere rating. Move load base. Will accept class T Fuses only. 4-pole switches are not approved for service entrance. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-29 SAFETY SWITCHES Type 3R — Outdoor List Price $ Type 1 — Indoor Number of Poles Safety Switches Double Throw Selection Accessories, Lug Data and Horsepower Ratings Wire Ranges (Line, Load and Neutral) per NEC Requirements Accessories – 2 and 3-Pole Switches Type “DT” Only햲 Catalog Number 3 Description Neutral Kits 30A 60 & 100A 200A 400 & 600A 800 & 1200A Equipment Ground Kit 30-200A 400 & 600A 800-1200A (2) #14-4 AWG (4) #14-2/0 (8) #6-350 Kcmil 30-200A 30-200A 400-1200A 400-1200A with with with with SAFETY SWITCHES Auxiliary Contacts (HD only) (two required per switch)햵 Class R Fuse Clip Kits (two required per switch) Class T Fuse Adapter Kits (two required per pole) Type 3R Hubs (30-200A) (1) (2) (1) (2) NO NO NO NO & & & & (1) (2) (1) (2) NC NC NC NC contact contacts contact contacts List Price $ 30-200A – 2, 3 & 4-Pole Switches HNC612 HN263 HNC264 HN678 HND678 97.00 225.00 352.00 838.00 919.00 Switch Ampere Rating Wire Range (Cu/Al) New VBII Design Line, Load and Neutral 0 30 (1) #14–6 HG61234 HG656 HG678 24.00 123.00 239.00 060 (1) #14–2 100 (1) #14–1/0 AWG HA161234 HA261234 HA165678 HA265678 239.00 266.00 587.00 614.00 100 (1) #14–1/0 AWG 200 (1) #6–250 kcmil 400-1200A – 2 & 3-Pole Switches Switch Ampere Rating HR21 HR612 HR62 HR63 HR64 100A, 100A, 200A, 200A, HT23 HT63 HT24 HT64 76.00 120.00 102.00 143.00 600 (2) 1/0 AWG–500 kcmil 800 (2) 1/0 AWG–750 kcmil or (3) 1/0 AWG–500 kcmil ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 39.50 39.50 39.50 39.50 69.00 109.00 1200 (3) 1/0 AWG–600 kcmil or (4) 1/0 AWG–500 kcmil For For For For For For 240V 600V 240V 600V Kit Kit Kit Kit ⁄4" Conduit 1" Conduit 1 1⁄4" Conduit 1 1⁄2" Conduit 2" Conduit 2 1⁄2" Conduit 3 83.00 83.00 83.00 54.00 54.00 400 Catalog Number Description (1) NO, (1) NC햵 (2) NO, (2) NC햵 Auxiliary Switch (two required per switch) Switch Ampere Rating 30-800A Ground Lug Kit햴 30-60-100A 200A 400-600-800A Hubs 30-60-100A 200-400A 600-800A 30-60-100A 200A 400 & 600A Fusible 400A 3P Non-Fusible 1-Phase AC 0 30 0 60 100 200 400 600 3-Phase AC 480V 600V 03 10 15 15 — — 0 71⁄2 15 30 60 125 125 015 030 060 125 125 — 020 050 075 150 125 — 05 10 20 40 50 50 05 10 15 15 — 10 20 40 60 125 020 050 075 125 250 030 060 100 150 350 05 10 20 40 50 240V DS100GK DS200GK DS468GK 12.00 203.00 292.00 DT100NK DT200NK DS800NK DT600NK 195.00 391.00 488.00 432.00 400 (1) 1/0 AWG–300 kcmil or (2) 1/0 AWG–750 kcmil 600 (2) 250-500 Kcmil 800 (3) 250-500 Kcmil Replacement Parts – 2 and 3-Pole Switches Only 햲 250V DC 240V 373.00 743.00 Wire Range (Cu/Al) New VBII Design Line, Load and Neutral Use Type HR Hubs Use Type SSH 4, 4X Hubs Use Type SSH 4, 4X Hubs Maximum Horsepower Ratings Fused Ampere Rating List Price $ DS200EK1 DS200EK2 (1) 1/0 AWG–750 kcmil or (2) 1/0 AWG–250 kcmil 400-800A – 4-Pole switches Accessories – 4-Pole and Type “F” & “NF” 3-Pole Switches Only햳 Neutrals (3-pole only) Wire Range (Cu/Al) New VBII Design Line, Load and Neutral 30A, 240V Kit 30A, 600V Kit/60A, 240V Kit 60A, 600V Kit 100A Kit 200A Kit Catalog Number Description Type 1, 3R & 12 Replacement Handle Type 4X Replacement Handle Replacement Handle 30-200A 30-200A 400-1200A List Price $ HHD61234 HHD61234S 98.00 174.00 HHD65678 143.00 Non-Fused 0 0 30 60 100 200 400-800 ▲ Built to order. Allow 6–8 weeks for delivery. 햲 For “DT” VBII Type switches only. 햳 Also for fusible stainless & 400A Type 12 & 4x switches. 3-30 햴 The following ground lugs are provided as standard in 200A and larger switches 200-(1) #14-4 Cu/Al 400-800A-(3) #6-250MCM Cu/Al. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햵 One aux. required for normal and one required for emergency switch line base. Discount Schedule HDSS & RESI Safety Switches Dimensions VBII Design Double Throw Dimensions (Inches) Enclosure Catalog Number Mounting A B C D E F Figure 1 (30-1200A Type 1 & 3R) 9.53 6.09 19.00 6.75 0.268 29.12 9.53 6.09 23.50 6.75 0.268 DTNF222, DTNF322, DTNF362, DTNF362R 24.88 11.50 6.09 19.00 9.38 0.268 DTF322, DTF322R, DTF362 33.45 11.50 6.09 27.50 9.38 0.268 DTNF223, DTNF323, DTNF323R, DTNF363, DTNF363R, DTGNF223R, DTGNF223NR, DTGNF323R , DTGNF323NR 27.62 12.18 6.09 19.36 8.00 0.268 DTF323, DTF323R, DTF363, DTF363R 36.44 12.18 6.09 28.11 8.00 0.268 DTNF224, DTNF224R, DTNF324, DTNF324R, DTNF364, DTNF364R, DTGNF224R, DTGNF224NR, DTGNF324R, DTGNF324NR 36.00 19.12 6.42 31.00 15.00 0.44 DTF224, DTF224R, DTF324, DTF324R, DTF364, DTF364R 49.44 19.12 6.42 44.50 15.00 0.44 DTF325, DTF326, DTF365 73.54 28.22 9.44 65.50 16.00 0.56 DTNF225, DTNF225R, DTNF325, DTNF365, DTNF365R 57.71 28.22 9.44 49.75 16.00 0.56 DTNF326, DTNF366, DTNF366R 57.71 28.22 9.44 49.75 16.00 0.56 DTNF327, DTNF367, DTNF367R 71.65 41.60 9.44 63.70 32.00 0.56 DTNF368, DTNF368R 71.65 41.60 9.44 63.70 32.00 NFR451DTK 햴, NFR452DTK 햴, NFR453DTK 햴 24.63 11.63 4.78 21.50 9.25 햲 0.25햲 NF454DTK 햳햴, NFR454DTK 햳햴 37.25 19.19 6.32 33.50 16.00 햳 0.56햳 8.88 58.50 22.25 햳 0.56햳 NF455DTK햴, NF456DTK햴, NF457DTK햴, NFR455DTK햴, NFR456DTK햴, NFR457DTK햴 63.31 27.00 0.56 Figure 2 (30-200A Type 12 & 4X) DTNF361J, DTNF361S 24.42 9.65 6.48 26.65 5.47 0.27 DTNF362J, DTNF362S 24.80 11.61 6.48 27.03 8.00 0.27 DTNF363J, DTNF363S 27.54 12.29 6.48 29.77 8.47 0.27 DTNF364J, DTNF364S 35.93 19.24 6.78 38.16 13.44 0.33 NF355HDTK햲, NF355SSDTK햲 53.82 22.66 7.25 56.20 18.00 0.56 F353SSDTK햳햴 37.00 11.62 5.50 38.50 9.00 0.26 F354SSDTK햳햴 50.90 19.16 6.46 53.27 16.12 0.50 F355SSDTK햳햴 74.50 25.00 8.92 76.69 20.25 0.56 E E D A D CL A CL (6) “F” dia. mounting holes (30-200A) (4) “F” dia. mounting holes (400-1200A) C (6) “F” dia. mounting holes (30-200A) (4) “F” dia. mounting holes (400-1200A) C B B Figure 1 Type 1 & 3R햵 *For inches / millimeters conversion, multiply inches by 25.4. 햲 햳 (3) Mounting holes supplied (1 at top). (4) Mounting holes provided. Figure 2 Type 4X & 12 햴 햵 These switches are not Type VBII design. Drip hood not shown but provided on Type 3R enclosures. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-31 SAFETY SWITCHES 24.50 DTF321, DTF321R, DTF361 3 DTNF221, DTNF321, DTNF361, DTNF361R Enclosed Switches Rotary Disconnect Switches in Non-Metallic Enclosures Application SAFETY SWITCHES 3 Siemens Rotary Disconnect switches are ideally suited for use as ”in sight“ disconnects for motor loads and other electrical equipment which is remotely located from its branch circuit protective device. All are supplied in non-metallic enclosures which are UL & CUL or CSA approved for a wide range of both indoor and outdoor environments. All meet UL508 requirements. Description 16–125A non-fusible switches are available in non-metallic enclosures which are UL approved as Type 12 & 4X and for either indoor or outdoor use. All are horsepower and load break rated. All are panel mounted and are either supplied with factory installed aux. contacts or will accept contact kits. All are compact in size while providing ample wiring space for copper line & load conductors. Siemens Enclosed Rotary Disconnect Switches ▪ 16–125A, Non-Fusible ▪ 600VAC max. rated (except catalog no. HNF3100CX is rated 480VAC max.) ▪ Available in both Type 12 and 4X non-metallic enclosures ▪ Both screw and hinged cover designs available 3-Pole, 3-Wire ▪ HP rated ▪ Rotary handles are available in black, red, and yellow and in pistol grip designs ▪ Listed and marked “suitable for use as motor disconnect” per NEC Section 430-109 ▪ 16–63A screw cover switches have factory installed ground bars. All hinge cover switches accept ground lug kits ▪ Screw cover switches are UL listed under File No. E47705 and are CSA certified under File No. 203576 ▪ IEC 60947-3 rated and CE marked (enclosures are IP65 rated) ▪ Screw cover switches are provided with knockouts ▪ Hinged door switches are UL listed for multiple line and load conductors per phase in 30–100A ratings. They are UL & CUL listed under File No. E191706 Catalog Number Ampere Rating Selection ▪ Padlockable in OFF position with up to (3) padlocks Horsepower Ratings List Price $ 3-Pole, 3-Wire with (1) NO & (1) NC Aux. Contact List Price $ Shipping Weight 240V AC 1-Phase 3-Phase 480V AC 3-Phase 600V AC 3-Phase Non-Fusible, Type 1, 4X & 12K with Screw Cover and Black Rotary Handle 600V AC Max. 16 25 30 30 30 63 100 125 3LD2064-0TB51-0US1 3LD2164-0TB51-0US1 3LD2264-0TB51-0US1 — — 3LD2565-0TB51-0US1 3LD2766-0TB51-0US1 3LD2866-0TB51-0US1 313.00 336.00 395.00 — — 579.00 929.00 1555.00 3LD2064-1GP51-0US1 3LD2164-1GP51-0US1 3LD2264-1GP51-0US1 3LD2264-1TS51-0US1 ▲ 3LD2264-2TW51-0US1 ▲ 3LD2565-1GP51-0US1▲ 3LD2766-1GP51-0US1▲ 3LD2866-1GP51-0US1▲ 355.00 378.00 437.00 453.00 483.00 621.00 1000.00 1613.00 1 1 1 1 1 3 6 6 11⁄2 3 3 3 3 10 — — 3 71⁄2 71⁄2 71⁄2 71⁄2 15 30 40 71⁄2 10 15 15 15 40 60 75 10 15 20 20 20 50 75 100 71⁄2 10 15 15 15 40 60 75 10 15 20 20 20 50 75 100 15 40 50 20 50 — Non-Fusible, Type 1, 4X & 12K with Screw Cover and Red and Yellow Rotary Handle 600V AC Max. 16 25 30 30 30 63 100 125 3LD2064-0TB53-0US1 3LD2164-0TB53-0US1 3LD2264-0TB53-0US1 — — 3LD2565-0TB53-0US1 3LD2766-0TB53-0US1▲ 3LD2866-0TB53-0US1▲ 313.00 336.00 395.00 — — 579.00 929.00 1555.00 3LD2064-1GP53-0US1 3LD2164-1GP53-0US1 3LD2264-1GP53-0US1 3LD2264-1TS53-0US1 ▲ 3LD2264-2TW53-0US1 ▲ 3LD2565-1GP53-0US1▲ 3LD2766-1GP53-0US1▲ 3LD2866-1GP53-0US1▲ 355.00 378.00 437.00 453.00 483.00 621.00 1000.00 1613.00 1 1 1 1 1 3 6 6 11⁄2 3 3 3 3 10 — — 3 71⁄2 71⁄2 71⁄2 71⁄2 15 30 40 Non-Fusible, Type 4X with Hinged Door and Black Pistol Grip Rotary Handle 480V AC Max. 30 60 100 HNF3030CX HNF3060CX HNF3100CX 870.00 1189.00 1494.00 ▲ Built to order. Allow 6–8 weeks for delivery. Carton quantity of (1). Shipping weight in pounds (lbs.). Approved for both indoor and outdoor use. No cover interlock provided. 30 and 60A switches are also rated 600V AC. Also rated as Type 12 and UL approved for both indoor and outdoor use. Defeatable cover interlock provided. 3-32 — — — — — — 4 4 5 Screw cover enclosures are constructed from Makrolon 9425. Hinged cover enclosures are constructed from fiberglass reinforced polycarbonate. Switch is supplied with (2) NO and no NC aux. contacts. Switch is supplied with (4) NO and no NC aux. contacts. Ground bar is not provided or available. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3 10 15 71⁄2 15 25 Aux. contacts break about 3 Ms before and make about 3 Ms after main switch contacts. 25A, switch with 1 NO & 1 NC aux. contacts and a black operating handle is also available. Order catalog number 3LD2165-4VD51 (Discount Code: Pilot Devices). 6P, Discount Schedule HDSS Enclosed Switches Rotary Disconnect Switches Selection Wire ranges 60/75°C Cu Only Enclosed Disconnect Switch Dimensions (Inches)* 3LD2 Type Switches Dimensions Catalog Number Ampere Fig. Rating No. A B C D 3LD20643LD21643LD22643LD25653LD27663LD2866HNF3030CX HNF3060CX HNF3100CX 16 25 30 63 100 125 30 60 100 5.52 5.52 5.52 6.93 11.90 11.90 7.87 11.77 11.77 3.94 3.94 3.94 5.75 8.35 8.35 7.87 7.87 7.87 3.19 3.19 3.19 4.10 5.36 5.36 5.20 5.20 5.20 4.57 4.57 4.57 5.87 7.13 7.13 7.29 7.29 7.29 1 2 16 Amps 25–30 Amps 63 Amps 100–125 Amps (1) #18- 10 AWG (1) #14 - 10 AWG (1) #14 - 6 AWG (1) #12- 1 AWG HNF Type Switches 30 Amps Note: 3LD2 Type switches only have top and bottom end KOs as follows: 16-30A - 1/2" & 3/4", 63A - 3/4" & 1", 100 & 25A - 1" & 1 1/4" Figure 1 D 60 & 100 Amps Figure 2 SAFETY SWITCHES (1) #14 - #10 AWG Solid (1) #14 - #1 AWG Stranded (2) #6 AWG Stranded Up to (3) #8 AWG Stranded Up to (6) #10 AWG Stranded Up to (6) #12 AWG Solid C A 3 (1) #14 - #10 AWG Solid (1) #14 - #4 AWG Stranded Up to (4) #12 AWG Solid Up to (3) #12 AWG Stranded Up to (6) #14 AWG Stranded Up to (4) #14 AWG Stranded with (1) #10 AWG Stranded D C B A UL and CUL Short Circuit Withstand Ratings Short Circuit Withstand Rating and Fuse Class With Load Side Fusing With Line Side Fusing Ampere 5 kA at Rating 600V Max 10 kA at 600V Max 18 kA at 480V Max 5 kA at 480V Max 18 kA at 480V Max 3LD2 Type Switches — — — — RK5 25 & 30 (80A Max) — — — — — — — — — — — 63 RK5 (175A Max) 100 & 125 — RK5 (200A Max) HNF Type Switches 30 — H, K & RK5 (100A Max) H, K & RK5 (150A Max) 60 100 For H, K & RK5 (30A Max) J, T & CC (100A Max) H, K & RK5 (60A Max) B IEC Fuse and Withstand Ratings RK5 (50A Max) 16 .5 Ferraz Shawmut A50P or lower let-through semiconductor fuses (60A Max) Ferraz Shawmut A50P or lower let-through semiconductor fuses (100A Max) use as supplemental protection on the load side of the branch circuit over current protective device. Ground lug kit has two lugs for #14-4 Cu/Al wire. Factory installed ground lugs supplied as follows: 16-30A #14-10 Cu, 63A #14-8 Cu. Ground lug not provided and is not available on catalog numbers 3LD2264-2TW51-0US1 and 3LD2264-2TW53-0US1. 6.38 inches high including mounting feet. 7.85 inches high including mounting feet. 60 & 100A HNF switches are rated 10kA at 480V max. with line side Class H, K & RK5 150A max. fuses. Wire range (1) #14-2 AWG 60/75 °C Cu only. 16-63A 3LD switches are also rated 5kA at 600VAC max when protected by a 3RV type MSP of the same or lesser ampere rating. *For inches / millimeters conversion, multiply inches by 25.4. Ampere Rating gG Fuse Size Short Circuit Rating 3LD2 Screw Cover Switches 16 20A 5k Arms 25 25A 10k Arms 32 50A 10k Arms 63 63A 15k Arms 100 100A 20k Arms 125 125A 20k Arms HNF Hinged Cover Switches 30 63A 10k Arms 60 100A 10k Arms 100 100A 10k Arms Accessories Switch Ampere Rating Catalog Number 3LD2 Type Switches List Price $ Description (Discount Schedule PILO) 16 –30A 3LD9220-2C 23.00 Neutral Kit 63A 3LD9250-2CA 32.00 Neutral Kit 100 –125A 3LD9280-2C 39.50 Neutral Kit HNF Type Switches (Discount Schedule HDSS) 30–100A GSGK60 24.00 Ground Lug Kit 30A LBRA1 59.00 Auxiliary Contact Kit (1 NO - 1 NC) 60 –100A LBRA2 65.00 Auxiliary Contact Kit (1 NO - 1 NC) 30 –100A HF63CX 76.00 Neutral Kit Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3-33 Enclosed Switches Enclosed Bolted Pressure Switches & Safety Switch Replacement Parts Selection For enclosed bolted pressure contact switches order as lug-in/lug-out single section BPS main switchboards using the SPACE 2000 Switchboard EPM. VBII Safety Switch Replacement Parts Line Base Ampere Rating Catalog Number Load Base List Price $ Catalog Number List Price $ Handle / Handle Guard General Duty Heavy Duty Catalog Number List Price $ Catalog Number — 51.00 — HH6123햸 — HH6123햸 62.00 — 62.00 — — — — — HH65678 — — — — — — — 137.00 — — HH6123햸 HH6123햸 HH6123햸 HH64햸 HH65678햸 HH65678햸 HH65678햸 HH68햸 62.00 62.00 62.00 87.00 137.00 137.00 137.00 131.00 — GH223 — GH223 GH24 HH65678 HH65678 — — — 51.00 — 51.00 61.00 137.00 137.00 — — HH6123햸 — HH6123햸 HH6123햸 HH64햸 HH65678햸 HH65678햸 HH65678햸 HH68햸 62.00 — 62.00 62.00 87.00 137.00 137.00 137.00 131.00 List Price $ SAFETY SWITCHES 3 Fusible 2- and 3-Pole 60-600A General Duty & 30-1200A Heavy Duty햶햹 30 HD 240V 60 GD 60 HD 240V HFB21햳 HFB612햳 HFB22햳 30 600V 60 600V 100 200 400 600 800 1200 HFB612햳 HFB62햳 HFB63햳 HFB64햳 HFB65햴햷 HFB66햴햷 HFB67A햳햷 HFB68햳햷 HBB21햳 HBB612햳 HBB22햳 84.00 137.00 141.00 HBB612햳 HBB62햳 HBB63햳 HBB64햳 HBB656햷 HBB656햴햷 HBB67A햳햷 HBB68햳햷 137.00 169.00 208.00 447.00 393.00 393.00 863.00 1063.00 56.00 81.00 83.00 81.00 97.00 176.00 256.00 225.00 225.00 473.00 691.00 — GH223 — Non-Fusible 3-Pole 60-600A General Duty & 30-1200A Heavy Duty햶햹 HNB612햳 HNB612햳 HNB623햳 HNB623햳 HNB64햳 HNB65햴햷 HNB66햴햷 HNB67A햳햷 HNB678햷 30 HD 60 GD 60 HD 100 200 400 600 800 1200 Ampere Rating 77.00 77.00 313.00 313.00 327.00 313.00 313.00 866.00 1056.00 — — — — — — — — — — — — — — — — — — Mechanism Assembly Line & Load Lugs Catalog Number Catalog Number List Price $ List Price $ Fusible 2- and 3-Pole 60-600A General Duty & 30-1200A Heavy Duty햶햹 30 HD 240V 60 GD 60 HD 240V HM6123햸 HM6123 HM6123햸 72.00 72.00 72.00 30 600V 60 600V 100 200 400 600 800 1200 HM6123햸 HM6123햸 HM6123햸 HM64햸 HM65 HM66 HM67A HM678 72.00 72.00 72.00 190.00 327.00 471.00 761.00 1314.00 HL612햲 HL612햲 HL612햲 HL612햲 HL612햲 HL63햲 HL64햲 HL65678햵 HL65678햵 HL67A햷햺 햺 38.50 38.50 38.50 38.50 38.50 97.00 165.00 37.50 37.50 109.00 — Non-Fusible 3-Pole 60-600A General Duty & 30-1200A Heavy Duty햶햹 HM6123햸 HM6123 HM6123햸 HM6123햸 HM64햸 HM65 HM66 HM67A HM678 30 HD 60 GD 60 HD 100 200 400 600 800 1200 HL612햲 HL612햲 HL612햲 HL63햲 HL64햲 HL65678햵 HL65678햵 HL67A햷햺 72.00 72.00 72.00 72.00 190.00 327.00 471.00 761.00 1314.00 햺 햲 햶 햳 햷 햴 햸 Three lugs included in kit. Includes lugs. Lugs not included. 햵 One lug per kit. 3-34 38.50 38.50 38.50 97.00 165.00 37.50 37.50 109.00 — One per switch required unless otherwise noted. One required per pole. For type 4/4X stainless steel switches add “S” to end of catalog number. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햹 햺 For replacement door for heavy duty switches add “DOOR” to end of switch catalog number. Lugs included with line and load bases. Discount Schedule HDSS 4SPEEDFAX TM 2007-2008 Disconnect Switches Contents Compact Non-Fusible Switches Rotary and Toggle Switch—Selection Dimensions and Wire Ranges 4-2 – 4-4 4-5 Type VBII (30-600A) Features and Ordering Information 4-6 Switch and Handle Selection 4-7 Accessories Dimensions and Lug Wire Ranges 4-8 – 4-9 4-10 Type MCS (30-200A) Switches, Fuse, and No Fuse Kit—Selection 4-11 Handle Operators and Accessories 4-12 4-13 Switch and Handle—Selection 4-14 Accessories 4-15 Dimensions and Technical Characteristics 4-16 Type VB Panelboard Units General and Withstand Ratings Catalog Numbering System Vacu-Break Fusible Units—Selection Accessories 4-17 4-18 4-19 – 4-20 4-21 Type HCP Switchboard Units Selection/Accessories 4-22 Dimensions 4-23 Type TFP Fusible Pullouts—Selection/Dimensions Residential Commercial Industrial 4-24 DISCONNECT SWITCHES Features and Ordering Information 4 Type CFS Compact Fusible Switches Disconnect Switches Compact Non-Fusible — Rotary and Toggle Selection Features ▪ 25 -100 Ampere, to 50 hp 480V and 600V ▪ Rotary and Toggle actuation models ▪ LBR Type switches are UL & CUL listed under File No. E191706 as manual motor controllers per UL Standard UL508 ▪ 3LD2 Type switches are UL listed under File No. E47705 per UL508 and are CSA certified under File No. 203576 DISCONNECT SWITCHES 4 ▪ Base, 35mm DIN-rail and door mounting ▪ Multiple conductor, distribution terminal type rating LBR & LBT Type (40A -100A only) Type LBR Rotary Switches Type LBT Toggle Switches ▪ IEC 947-1 rated, CE marked ▪ Listed and marked “suitable as motor disconnect” per NEC Section 430-109 Short Circuit Withstand Ratings Switch Rating & Type Max. Line Side Fuse Rating Application Siemens Load Break Switches are listed as manual motor controllers and are suitable as motor disconnects. They are load break rated and act as enclosure disconnects when short circuit protection is provided upstream of the switch. If upstream over current protection is not provided, use a Siemens fusible Type VBII, CFS or MCS Disconnect Switch. Ordering Information Door Mounted Switches (Rotary Type Only) — Order either complete “3LD2” assemblies or individual “LBR” components as follows: Complete Assemblies include switch, handle, and shaft. Certain 25 and 32A assemblies are also available with factory installed neutral blocks and/or aux. contacts. These accessories can also be ordered as field installed kits. Individual Components are ordered as follows: 25A — LBR3025D switch + LBRH3 or 4 handle. 40 –100A — LBR switch + LBRH3 or 4 handle + LBRD1. Notes: (LBR Type switches only) 1. Aux contacts are available as field installed kits on 25A units only. 2. Lugs on 25A units face to the rear and lugs on 40 –100A units face toward the front. 왎 Built to order. Allow 6–8 weeks for delivery. auxiliary contacts (1 NO and 1 NC). Includes 4-2 5kA with Line Side Class H, K, or RK5 Fuses 25 & 32A 3LD2 63A 3LD2 3LD2254-0TK51 Base/DIN Rail Mounted Switches (Rotary or Toggle Type) — Order 80A Max. at 600V AC Max. 175A Max. at 600V AC Max. 10kA with Line Side Class H, K, or RK5 Fuses 25A LBR 30A Max. at 480V AC Max. either complete assemblies or individual components as follows: 40A, 4P LBR & LBT 60A Max. at 480V AC Max. Complete Assemblies include switch, handle, and shaft. 40 & 60A, 3P LBR & LBT 100A Max. at 480V AC Max. 80 & 100A LBR & LBT 150A Max. at 480V AC Max. Individual Components are ordered as follows: Toggle — Order the LBT switch required and a toggle switch cover plate if needed. Rotary, Base Mounted with Door Mounted Handle — Order “LBR” switch + door mounted handle + shaft + any accessories. 18kA with Line Side Class J, T, or CC Fuses 40 –100A, 3P LBR & LBT 100A Max. at 480V AC Max. Note: 3LD2 switches are also rated 5kA at 600V AC Max. when protected by a 3RV motor starter with a FLA rating equal to or less than the switch ampere rating. Rotary, Base Mounted with Direct Mounted Handle — Order “LBR” switch + direct mounted handle. 3LD Type Door Mounted Complete Assemblies (Operator, Shaft, & Switch) 600V AC Max. Shaft Mounted 4 Hole Mounted AC Horsepower Ratings Catalog Number List Price $ Catalog Number List Number Price $ of Poles 3LD2154-0TK_ _ 3LD2154-1TP_ _ 3LD2154-1TL_ _ 3LD2154-2EP__ 81.00 106.00 101.00 123.00 3LD2103-0TK_ _ 81.00 3LD2103-1TP_ _ 106.00 3LD2103-1TL_ _ 101.00 3LD2103-2EP_ _ 123.00 3 3 3+N 3 + N 3LD2254-0TK_ _ 3LD2254-1TL_ _ 3LD2555-0TK_ _ — — — 96.00 118.00 155.00 — — — 3LD2203-0TK_ _ 3LD2203-1TL_ _ 3LD2504-0TK_ _ 3LD2504-3VK53 3LD2704-0TK_ _ 3LD2804-0TK_ _ 3 3+N 3 6 3 3 90.00 122.00 155.00 224.00 235.00 300.00 Handles are IP65 rated and are also UL listed for Type 1, 4X and 12 applications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Ampere Rating 120V 1Ø 240V 480V 1Ø 3Ø 3Ø 600V 3Ø 25 2 3 71/2 10 15 32 2 3 10 20 20 63 63 100 125 — — — — 10 10 — — 15 15 30 40 40 40 60 75 50 50 75 100 Add 51 for a black handle or 53 for a red & yellow handle to the end of the catalog number. Discount Schedule PILO Disconnect Switches Compact Non-Fusible — Rotary and Toggle Selection 3LD Type Base Mounted Complete Assemblies (Operator, Shaft, & Switch) 600V AC Max. Handle Mounting Shaft (center hole) 4 Hole Catalog Number List Price $ Catalog Number AC Horsepower Ratings 3LD2144-0TK_ _ 3LD2144-1TL_ _ 138.00 154.00 3LD2113-0TK_ _ 132.00 3LD2113-1TL_ _ 149.00 3 3+N 3LD2244-0TK_ _ 3LD2244-1TL53 3LD2545-0TK_ _ — — 154.00 138.00 207.00 — — 3LD2213-0TK_ _ 3LD2213-1TL53 3LD2514-0TK_ _ 3LD2714-0TK_ _ 3LD2814-0TK_ _ 3 3+N 3 3 3 List Number Price $ of Poles 144.00 165.00 171.00 282.00 352.00 Ampere Rating 120V 1Ø 240V 480V 1Ø 3Ø 3Ø 600V 3Ø 25 2 3 71/2 10 15 32 2 3 10 20 20 63 100 125 — — — 10 — — 15 30 40 40 60 75 50 75 100 Note: Shaft length allows a maximum depth from switch mounting surface to the outside of the cover of 15.25" on 25 & 32A switches and of 15.75" on 63-125A switches. 3LD2213-0TK53 Accessories for Front Mounted 3LD2 Switches 3LD9220-2B 3LD9250-2BA 3LD9280-2B Neutral/Ground Terminal Neutral/Ground Terminal Neutral/Ground Terminal 25 & 32A 63A 100 & 125A 23.00 32.00 39.50 3LD9220-0B 3LD9250-0BA 3LD9280-0B 4th Pole (leading ON, lagging OFF) 4th Pole (leading ON, lagging OFF) 4th Pole (leading ON, lagging OFF) 25 & 32A 63A 100 & 125A 28.50 46.50 57.00 3LD9224-1B 3LD9284-1B 3LD9224-3B 3LD9284-3B Black Handle (4 hole mtg.) Black Handle (4 hole mtg.) Red/Yellow Handle (4 hole mtg.) Red/Yellow Handle (4 hole mtg.) 25 & 32A 63-125A 25 & 32A 63-125A 15.00 39.50 15.00 39.50 3LD9224-1D 3LD9284-1D 3LD9224-3D 3LD9284-3D Black Handle (shaft mtg.) Black Handle (shaft mtg.) Red/Yellow Handle (shaft mtg.) Red/Yellow Handle (shaft mtg.) 25 & 32A 63-125A 25 & 32A 63-125A 15.00 39.50 15.00 39.50 3LD9221-2A 3LD9251-2A 3LD9281-2A 3LD9221-0A 3LD9251-0A Terminal Terminal Terminal Terminal Terminal 25 & 32A 63A 100-125A 25 & 32A 63A 3.00 3.00 4.60 9.00 10.60 Cover Cover Cover Cover Cover 1P 1P 1P 3P 3P (Pack (Pack (Pack (Pack (Pack of of of of of 4) 4) 4) 4) 4) List Price $ 33.00 57.00 DISCONNECT SWITCHES 1 NO, 1 NC Aux. Contact 1 NO, 1 NC Aux. with Gold Plated Contacts Switches Used With 25-125A 25-125A Description 4 Catalog Number 3LD9200-5B 3LD9200-5BF 3LD9220-2C Accessories for Base Mounted 3LD2 Switches Catalog Number 3LD9200-5C 3LD9200-5CF 1 NO, 1 NC Aux. Contact 1 NO, 1 NC Aux. with Gold Plated Contacts Switches Used With 25-125A 25-125A 3LD9220-2C 3LD9250-2CA 3LD9280-2C Neutral/Ground Terminal Neutral/Ground Terminal Neutral/Ground Terminal 25 & 32A 63A 100 & 125A 23.00 32.00 39.50 3LD9220-0C 3LD9250-0CA 3LD9280-0C 4th Pole (leading ON, lagging OFF) 4th Pole (leading ON, lagging OFF) 4th Pole (leading ON, lagging OFF) 25 & 32A 63A 100 & 125A 28.50 46.50 57.00 3LD9224-1B 3LD9284-1B 3LD9224-3B 3LD9284-3B Black Handle (4 hole mtg.) Black Handle (4 hole mtg.) Red/Yellow Handle (4 hole mtg.) Red/Yellow Handle (4 hole mtg.) 25 & 32A 63-125A 25 & 32A 63-125A 15.00 39.50 15.00 39.50 3LD9224-1D 3LD9284-1D 3LD9224-3D 3LD9284-3D Black Handle (shaft mtg.) Black Handle (shaft mtg.) Red/Yellow Handle (shaft mtg.) Red/Yellow Handle (shaft mtg.) 25 & 32A 63-125A 25 & 32A 63-125A 15.00 39.50 15.00 39.50 3LD9221-2A 3LD9251-2A 3LD9281-2A 3LD9221-0A 3LD9251-0A Terminal Terminal Terminal Terminal Terminal 25 & 32A 63A 100-125A 25 & 32A 63A 3.00 3.00 4.60 9.00 10.60 Description Handles Cover Cover Cover Cover Cover 1P 1P 1P 3P 3P (Pack (Pack (Pack (Pack (Pack and line side terminal covers are supplied as standard with 3LD2 switches. suffix 51 for a black handle or 53 for a red & yellow handle to the catalog number. Handles are 1P65 rated and are also UL listed for Type 1, 4X & 12 applications. Add Discount Schedule PILO of of of of of 4) 4) 4) 4) 4) Add List Price $ 33.00 57.00 51 for a black handle or 53 for a red & yellow handle to the end of the catalog number. 3LD9251-0A Aux. contacts break about 30 Ms before and make about 3 Ms after main switch contacts. Ratings 10A at 120V AC 6A at 240V AC 1.4A at 480V AC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-3 Disconnect Switches Compact Non-Fusible — Rotary and Toggle Selection Individual Components Rotary and Toggle Switches Catalog Number LBR3025 LBR3025D LBR3040 LBR3060 LBR3080 LBR3100 LBR4040 LBT3040 LBT3060 LBT3080 LBT3100 LBT4040 Switch Type Rotary Rotary Rotary Rotary Rotary Rotary Rotary Toggle Toggle Toggle Toggle Toggle AC Horsepower Ratings Max No. of Ampere AC 115V 240V 480V 600V Poles Rating Volt 1Ø 1Ø 3Ø 3Ø 3Ø 3 3 25 480 ⁄4 2 5 10 — 3 3 25 480 ⁄4 2 5 10 — 1 3 40 600 2 3 7 ⁄2 20 25 3 60 480 2 5 10 25 — 3 80 600 3 10 20 40 50 3 100 480 5 15 25 50 — 4 40 480 2 3 71⁄2 20 — 25 3 40 600 2 3 71⁄2 20 3 60 480 2 5 10 25 — 3 80 600 3 10 20 40 50 3 100 480 5 15 25 50 — 4 40 480 2 3 71⁄2 20 — List Price $ 99.00 108.00 118.00 141.00 169.00 208.00 184.00 118.00 141.00 169.00 208.00 184.00 Standard Duty Rotary Switch Door Handles Heavy Duty Rotary Switch Door Handle DISCONNECT SWITCHES 4 LBR Type Handles Catalog Number Standard Duty LBRH2 LBRH3 LBRH4 LBRH9 LBRH10 LBRH5 LBRH6 LBRH7 LBRH8 Heavy Duty CFSH10B12 CFSH10R12 Used on Rotary Switches NEMA Type All All All All (Pistol Grip Type) All (Pistol Grip Type) 25 Amps 3-Pole, 40-60 Amps 3-Pole, 80-100 Amps 4-Pole, 40-60 Amps 1 1, 1, 1, 1, 1 1 1 1 All All 1, 3R, 12 1, 3R, 12 3R, 3R, 3R, 3R, 12, 12, 12, 12, 4X 4X 4X 4X Mounting Marking Color Cover Interlock Supplied Door Door Door Door Door Direct Direct Direct Direct ON/OFF O/I, ON/OFF O/I, ON/OFF O/I, ON/OFF O/I, ON/OFF O/I O/I O/I O/I Black Black Red/Yel Black Red/Yel Black Black Black Black No Yes Yes Yes Yes — — — — No Yes Yes Yes Yes Yes Yes Yes Yes 34.50 51.00 51.00 130.00 130.00 16.10 21.00 21.00 21.00 O/I, ON/OFF O/I, ON/OFF Black Red/Yel Yes Yes Yes Yes 137.00 137.00 Mount Mount Mount Mount Door Door Padlockable List Price $ LBR Type Rotary Shafts Catalog No Length In. (mm) For Standard Duty Handles LBRS040 1.57 (40) LBRS050 1.97 (50) LBRS055 2.17 (55) LBRS080 3.15 (80) LBRS120 4.72 (120) LBRS180 7.09 (180) LBRS305 12.00 (305) For Heavy Duty Handles CFSS5200H 7.9 (200) CFSS5400H 15.7 (400) List Price $ 16.10 21.00 21.00 24.00 27.00 31.50 34.50 34.00 36.00 Rotary Shafts LBR 25 Amp, 4th Pole Used on Catalog No Catalog No LBR3025 LBRP25 LBR3025D LBRP25D List Price $ 68.00 76.00 LBT Type Toggle Switch Cover Plate LBR Auxiliary Switch Kits Used on Rotary Switch LBR3025 LBR3025D LBR3040, LBR3060 LBR3080, LBR3100 Catalog Number LBRA25 LBRA25D LBRA1 LBRA2 Contact Arrangement 1 NO/1 NC 1 NO/1 NC 1 NO/1 NC with common point 1 NO/1 NC with common point List Price $ 51.00 51.00 59.00 65.00 Used on Toggle Switches LBT3040, LBT3060 LBT3080, LBT3100 LBT4040 cover interlock defeat mechanism provided. To eliminate cover interlock, order additional catalog number LBRDC1. LBRH2 is IP54 rated. All others are IP65. Ratings 15.1A resistive at 250V AC max. .5A at 125V DC .25A at 250V DC .5 HP at 250V AC max. 4-4 Catalog Number LBTCP1 LBTCP2 LBTCP3 List Price $ 25.50 27.00 30.50 LBR Type Rotary Switch Door Mounting Kit (For use with LBRH3 & LBRH4 only) Used on Rotary Switch Catalog Number 40-100 Amps LBRD1 List Price $ 59.00 LBR/LBT Neutral Kit Used with Catalog Number All No Toggle Switch Cover Plates Rotary Switch Direct Mount Handles Auxiliary switch contacts break about 30 Ms before and make about 3 Ms after main switch contacts. Cannot be used with LBRD1 door mounting kit. Lug wire ranges: HF63CX —(1) #14-2 AWG 60/75°C Cu only Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog Number HF63CX List Price $ 76.00 Only door mountable and for use with LBRH3 & 4 handles only. door mounting of 40–100A LBR switches use door mounting kit LBRD1 & LBRH3 or 4 handle. For Discount Schedule HDSS Disconnect Switches Compact Non-Fusible — Rotary and Toggle Dimensions Dimension Drawings and Wire Ranges Dimension J Minimum Dept h햲 3.15 in. (80 mm) Switch 1.38 in. (35 mm) 2.92 in. (74 mm) 1.77 in. (45 mm) 0.20 in. (5 mm) 0.87 in. (22 mm) 1.54 in. (39 mm) Dimension J LBR 40-100A 3.35 (85) 3LD2 25 & 32A Front Shaft Mounted 3LD2 63 Front Shaft Mounted 3LD2 25 &32A Front 4-hole Mounted 3LD2 63A Front 4-hole Mounted 3LD2 100 & 125A Front 4-hole Mounted 3.07 (78) 3.35 (85) 2.13 (54) 2.48 (63) 2.56 (65) 3LD2 25 & 32A Base w/shaft Mtg. Handle 3LD2 63A Base w/shaft Mtg. Handle 3LD2 25 & 32A Base w/4-hole Mtg. Handle 3LD2 63A Base w/4-hole Mtg. Handle 3LD2 100 & 125A Base w/hole Mtg. Handle 6.46 (164) 6.77 (172) 5.59 (142) 5.99 (152) 6.07 (154) 0.71 in. (18 mm) J 2.24 in. (57 mm) 1.42 in. (36 mm) 햲 C A E F 0.16 in. (4 mm) 햲 B LBR 3025 H 0.31 in. (8 mm) Wire Ranges 60/75°C Cu only 25 Amps LBR (1) #14 - #10 AWG Solid (1) #14 - #8 AWG Stranded 40 & 60 Amps LBR & LBT (1) #14 - #10 AWG Solid (1) #14 - #4 AWG Stranded UP to (4) #12 AWG Solid Up to (3) #12 AWG Stranded Up to (6) #14 AWG Stranded Up to (4) #14 AWG Stranded with (1) #10 AWG Stranded 80 & 100 Amps LBR & LBT 25A, 3LD21 32A, 3LD22 63A, 3LD25 100, 125A, 3LD2 G DISCONNECT SWITCHES 3.35 in. (85 mm) Minimum Depth D 4 2.76 in. (70 mm) (1) #14 - #10 AWG Solid (1) #14 - #1 AWG Stranded (2) #6 AWG Stranded Up to (3) #8 AWG Stranded Up to (6) #10 AWG Stranded Up to (6) #12 AWG Solid (1) (1) (1) (1) #14-8 #14-8 #14-6 #12-1 Drilling Pattern .125 (3.2) LBR 40-100 Amps & 3LD2 25-125A 3.00 in. (76 mm) Minimum Depth .95 (24.1) C .877 (22.5) A E F D Shaft Mounted 3LD2 Handle Cutout 0.16 in. (4 mm) G B AWG AWG AWG AWG H 0.31 in. (8 mm) LBT Toggle — 40-100 Amps Switch Type Dimensions Inches (mm) Switch Catalog Number A B C Rotary Rotary Rotary Rotary Rotary Rotary Front Mtg. Rotary Front Mtg. Rotary Front Mtg. LBR3040 LBR3060 LBR3080 LBR3100 LBR4040 3LD21 & 2 햳 3LD25 햳 3LD27 & 8 2.00 2.00 2.09 2.09 2.42 1.81 2.36 2.40 2.72 2.72 2.92 2.92 2.72 1.97 2.32 2.40 Rotary Base Mtg. Rotary Base Mtg. Rotary Base Mtg. 3LD21 & 2 3LD25 3LD27 & 8 1.81 (46) 2.36 (60) 2.80 (71) 2.17 (55) 2.52 (64) 3.27 (83) 2.29 (58) 2.68 (68) 2.76 (70) — — — Toggle Toggle Toggle Toggle Toggle LBT3040 LBT3060 LBT3080 LBT3100 LBT4040 2.00 2.00 2.09 2.09 2.42 2.72 2.72 3.32 3.32 2.72 2.75 2.75 2.90 2.90 2.75 1.78 1.78 1.97 1.97 2.28 햲 Depth from outside of cover to back of switch. (51) (51) (53) (53) (61) (46) (60) (61) (51) (51) (53) (53) (61) 2.72 2.72 3.32 3.32 2.72 2.17 2.52 3.27 (69) (69) (84) (84) (69) (55) (64) (83) (69) (69) (84) (84) (69) D (69) (69) (74) (74) (69) (50) (59) (61) (70) (70) (74) (74) (70) 1.78 1.78 1.97 1.97 2.28 — — — E (45) (45) (50) (50) (58) 2.16 2.16 2.29 2.29 2.16 — — — F (55) (55) (58) (58) (55) — — — (45) (45) (50) (50) (58) 2.16 2.16 2.29 2.29 2.16 1.67 1.67 1.69 1.69 1.67 — — — G (42) (42) (42) (42) (42) — — — (55) (55) (58) (58) (55) 1.67 1.67 1.69 1.69 1.67 1.50 1.50 1.66 1.66 1.50 — — — H (38) (38) (42) (42) (38) — — — (42) (42) (42) (42) (42) 1.50 1.50 1.66 1.66 1.50 1.22 1.22 1.66 1.66 1.22 — — — (31) (31) (42) (42) (31) — — — (38) (38) (42) (42) (38) 1.22 1.22 1.66 1.66 1.22 (31) (31) (42) (42) (31) 햳 Handle front plate dimensions: 3LD21 & 2—2.64 inches square 3LD25, 7 & 8—3.55 inches square Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-5 Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features and Ordering Information Features ▪ Short circuit rating of 10,000 AIC with class H fuse, and of 200,000 AIC with class R or J fuses ▪ Flange mounted handles are Type 1 and 12 rated and padlockable in the off position with up to (3) padlocks with 5/16 hasps 햲 ▪ Meets UL98 requirements and suitable for both main and branch circuit applications ▪ A complete line of aux contacts are available ▪ Load break and horsepower rated ▪ Defeatable cover interlock standard with all handles ▪ Meets NFPA79 requirements DISCONNECT SWITCHES 4 ▪ 30-600A, 600VAC and DC ratings ▪ UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 154852 ▪ Visible blade quick make and break switching action ▪ Panel and Flange mounted assemblies facilite installation ▪ Panel mounted switches are variable depth VBFS361, VBLK1 & VBH1 VBFS363F VBNFS365, VBLK4 & VBH2 Ordering Information 1. Determine the ratings required (amps, volts, HP, Fusible, NF), the mounting needed (Panel or Flange), and select the appropriate switch. 햲 2. For panel mounted switches with a rigid operating shaft (30-600A), order panel mounted switch flange mounted operating handle & rigid linkage kit based on depth required. 3. For panel mounted switches with a Max-Flex operator, order panel mounted switch, Max-Flex Handle & Adapter Kit and drive cable. 30-200A handles are also rated Type 3R & 4X. 4-6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4. Select accessories if required. Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Selection Switches Switch Ampere Rating Horsepower Rating, Switches and 3-Phase햵 Max. AC Voltage Rating 240 Volts AC Catalog Number Standard 480 Volts AC Max. Standard 600 Volts AC Max. Standard Max. 600 Volts DC (max)햵 List Price $ Fusible Panel Mounted Variable Depth Switches - 3-Pole햶햸 30 60 30 60 100 200 400 600 240 240 600 600 600 600 600 600 VBFS321 VBFS322 VBFS361 VBFS362 VBFS363 VBFS364 VBFS365 VBFS366 3 7 1/2 — — — — — — 7 1/2 15 — — — — — — — — 5 15 25 50 100 150 — — 15 30 60 125 250 400 — — 7 1/2 15 30 60 125 200 — — 20 50 75 150 350 500 —햲 —햳 15 햴 30 햴 50 햴 50 50 햴 50 햴 582.00 670.00 605.00 710.00 1327.00 2446.00 4649.00 7098.00 햴 Non-fusible Panel Mounted Variable Depth Switches - 3-Pole햶 30 60 100 200 400 600 600 600 600 600 600 600 VBNFS361 VBNFS362 VBNFS363 VBNFS364 VBNFS365 VBNFS366 — — — — — — 10 20 40 60 125 200 — — — — — — 20 50 75 125 250 400 — — — — — — 30 60 100 150 300 500 15 30 50 50 50 50 햴 529.00 605.00 1074.00 1813.00 3446.00 5261.00 3 7 1/2 — — — — 7 1/2 15 — — — — — — 5 15 50 100 — — 15 30 60 125 — — 7 1/2 15 30 60 — — 20 50 75 150 —햲 —햳 15 햴 30 햴 50 햴 50 851.00 940.00 875.00 981.00 1597.00 2718.00 10 20 40 60 — — — — 20 50 75 125 — — — — 30 60 100 150 15 30 50 50 햴 798.00 875.00 1344.00 2084.00 햴 햴 햴 Fusible Flange Mounted Switches - 3-Pole햷 VBFS321F VBFS322F VBFS361F VBFS362F VBFS363F VBFS364F Non-fusible Flange Mounted Switches - 3-Pole햷 30 60 100 200 600 600 600 600 VBNFS361F VBNFS362F VBNFS363F VBNFS364F — — — — 햴 햴 Note: Fusible switches include fuse provisions for Class H Fuses. The load base can be moved to pre-drilled holes for Class J Fuses. If Class R Fuses are required add a Class R Fuse Clip Kit. Flange Mounted Operating Handles Cable Kit For use with Panel Mounted Switches. Included with Flange Mounted Switches as standard. For use with 30-200A panel mounted switches and Max-Flex handle and adapter kit. Catalog Number Handle Assembly Description List Price $ Catalog Number Description List Price $ VBH1 30-200A Type 1, 3R & 12 240.00 FHOEC036 36" long drive cable 153.00 VBH14X 30-200A Type 4X 399.00 FHOEC048 48" long drive cable 182.00 VBH2 400 Type 1 & 12 476.00 VBH2R 400 & 600A Type 1, 3R & 12 560.00 VBH24X 400 & 600A Type 4X 760.00 Rigid Linkage Kits For use with Panel Mounted Switches. Not required for Flange Mounted Switches. Catalog Number Switch Ampere Rating VBLK1 VBLK2 30-200 30-200 6.94햹 6.94햹 6.94햹 19.0 29.50 35.00 VBLK3 VBLK4 400 & 600 400 & 600 9.00 9.00 8.75 19.0 46.50 54.00 Enclosure Depth햸 Min Max. List Price $ Max-FlexTM Handle and Adapter Kit (Type 1, 12, 3R & 4X) Use with 30-200A panel mounted switches and cable kit. Catalog Number Description List Price $ VBHM1 30-200A Max-Flex Adapter Kit 424.00 햲 Rated 5 HP at 250V DC. Rated 10 HP at 250V DC. 600V DC & 600V DC horsepower rating shown requires (2) poles to be connected in series. 햵 Std. - applies when non-time delay fuses are used. Max. - applies when time delay fuses are used. 햳 햴 Discount Schedule HDSS 햶 VBNFS361, VBHM1 & FHOEC036 Includes line base, load base, operating mechanism and line and load lugs. Order operating handle and linkage kits from tables on this page. 햷 Includes line base, load base, operating mechanism line and load lugs operating handle and required linkage. 햸 Dimensions (min. & max.) from enclosure mounting pan to outside surface of enclosure handle mounting flange. 햹 7.12 for 200A switches. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-7 DISCONNECT SWITCHES 240 240 600 600 600 600 4 30 60 30 60 100 200 Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Accessories HT63 HR612 HN612 Class R Fuse Clip Kits Class T Fuse Adapter Kits 200% Neutral Kits These kits prevent the installation of Class H and K fuses (one kit required per switch). 100-600A fusible switches are field convertible to accept Class T fuses. 400-600A switches are field convertible to accept Class T fuses by moving the load base to a pre-drilled T fuse position. UL listed 200% Neutrals are available on 60 & 100A switches. They are typically used with non-linear transformers or where increased neutral ampacity/lug capacity is required. 4 Catalog Number DISCONNECT SWITCHES Class R Fuse Clip Kits HR21 83.00 30A, 240V Kit (HD only) HR612 83.00 30A, 600V Kit/60A, 240V Kit HR62 83.00 60A, 600V Kit Catalog Number HR63 54.00 100A Kit HT23 76.00 100A, 240V Kit HR64 54.00 200A Kit HT63 120.00 100A, 600V Kit HR656 137.00 400A/600A Kit HT24 102.00 200A, 240V Kit HT64▲ 143.00 200A, 600V Kit List Price $ Description Class T Fuse Adapter Kits햲 List Price $ Description Class J Fuse Provisions Neutral Kits All 30-600A, 600V fusible switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. Standard Neutral Kits can be field installed in 30-100A switches. 200% Neutral Kits Switch Ampere Rating 100 Kit Catalog List Number Price $ HN263 225.00 Wire Range Line & Load Lugs (Cu/Al) (2) #14-1/0 AWG Neutral Kits Switch Ampere Rating 30A 600V, 60A 240V Kit Catalog Number HN612 60A, 600V & 100A HN623 List Price $ 97.00 186.00 Internal Door Latch Kits For use with enclosures with door mounted latching bar. Required when a flange mounted switch is mounted in a Hoffmann or Rittal enclosure provided with an AB cutout. Catalog Number Description List Price $ DKR2 2 point (for use with enclosures less than 40" high) 338.00 DKR3 3 point (for use with enclosures 40" or larger in height) 377.00 Window Kits (Type 1, 12, 3R and 4x) Allows viewing of visible blades and of indicating fuses through 200A. Catalog Number Description List Price $ VBWK1 30A Window Kit 109.00 VBWK2 60 & 100A Window Kit 118.00 VBWK3 200-600A Window Kit 123.00 ▲ Built to order. Allow 6–8 weeks for delivery. 햲 One kit per pole required. 4-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule HDSS Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Accessories Auxiliary Contacts The auxiliary contacts are available in 1 normally open and 1 normally closed or 2 normally open and 2 normally closed configurations. Siemens offers a PLC Auxiliary Switch (30 -200A) that has very low resistance for low voltage and current typical in PLC circuits. All auxiliary contacts make after and break before main switch contacts. HA161234 Switch Ampere Rating Kit Ampere Rating Aux. Switch Catalog List Number Price $ 125V AC Max. 250V AC Max. Kit Horsepower Rating 28V DC 125V AC Max. Max. 250V AC Max. 28V DC Max. With 1 NO & 1 NC Isolated Contacts 30-200 HA161234 239.00 10 10 — 1/2 3/4 — 400-600 HA165678 587.00 10 10 — 1/2 3/4 — With 2 NO & 2 NC Isolated Contacts 30-200 HA261234 266.00 10 10 7 1/2 3/4 — 400-600 HA265678 614.00 10 10 7 1/2 3/4 — Low Current PLC Type with 1 NO & 1 NC Gold Plated Contacts HA361234 302.00 10 10 — 1/2 3/4 — HA365678 643.00 10 10 — 1/2 3/4 — 4 30-200 400-600 DISCONNECT SWITCHES HA261234 Fuse Puller Kits Fuse Puller Kits are field installable in 30-100A Type VBII Heavy Duty Switches (one kit required per 3-pole switch). Switch Ampere Rating 030 Fuse Puller Kit Catalog Number HP61 List Price $ 21.00 060 HP62▲ 21.00 100 HP63▲ 21.00 HP61 Copper Lug Kits All switches are UL approved to accept field installed copper lug kits. Switch Ampere Rating 30–60 Copper Lug Catalog List Number Price $ Description HLC612 138.00 (9) Lugs/Kit #14-4 AWG Cu 100 HLC63▲ 172.00 (9) Lugs/Kit #14-1/0 AWG Cu 200 HLC64▲ 212.00 (9) Lugs/Kit #6 AWG-300 Kcmil Cu 400–600A HLC65678 37.50 (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu Equipment Ground Kits Equipment Ground Lug Kits are available for all switches. HLC612 Switch Ampere Rating 30–200 Catalog Number HG61234 400 & 600 HG656 List Price $ 24.00 123.00 Number of Terminals 2 Wire Range Per Terminal (Cu/Al) #14-4 AWG 4 #6 AWG-250 Kcmil ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule HDSS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-9 Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Lug Wire Ranges & Dimensions Lugs 30 & 60A switches are suitable for use with 60° or 75°C wire. 100–600A switches are suitable for use with 75°C rated wire. All switches are supplied with factory installed line and load lugs. Wire Ranges (Line, Load and Standard Neutral) Switch Ampere Rating 30 60 UL Approved Wire Range Lug Wire Range #14-6 AWG (Cu/AI) #14-2 AWG (Cu/Al) #14-2 AWG (Cu/AI) #14-2 AWG (Cu/Al) #14-1/0 AWG (Cu/Al) #14-1/0 AWG (Cu/Al) 200 #6 AWG-300 Kcmil (Cu/Al) #6 AWG-300 Kcmil (Cu/Al) 400 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-250 Kcmil (Cu/Al) (1) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-250 Kcmil (Cu/Al) 600 (2) 1/0 AWG-750 Kcmil (Cu/Al) or (4) 1/0 -250 Kcmil (Cu/Al) (2) 1/0 AWG-750 Kcmil (Cu/Al) or (4) 1/0 AWG-250 Kcmil (Cu/Al) DISCONNECT SWITCHES 4 100 Approximate Dimensions Mounting bracket shown with handle installed is supplied with Flange Mounted Switches only. All Panel Mounted Switches have a “L” shaped mounting pan with a line base, load base (if fusible) and mechanism installed. Catalog Number A Fusible, Panel Mounted B Dimensions C D (min) D (max) VBFS321 11.88 N/A 6.62 6.81 19 VBFS322 13.12 N/A 8.50 6.81 19 VBFS361 11.88 N/A 6.62 6.81 19 VBFS362 13.12 N/A 8.50 6.81 19 VBFS363 13.12 N/A 8.50 6.81 19 VBFS364 17 N/A 12.33 7.05 19 VBFS365 26.25 N/A 16.50 8.63 19 VBFS366 26.25 N/A 16.50 8.63 19 B A Non-fusible, Panel Mounted VBNFS361 9.79 N/A 6.62 6.81 19 VBNFS362 9.79 N/A 8.50 6.81 19 VBNFS363 9.79 N/A 8.50 6.81 19 VBNFS364 10.77 N/A 12.33 7.05 19 VBNFS365 13 N/A 16.50 8.63 19 VBNFS366 13 N/A 16.50 8.63 19 Fusible, Flange Mounted D VBFS321F 11.88 14.06 7.00 7.27 N/A VBFS322F 13.12 15.83 8.85 7.27 N/A VBFS361F 11.88 14.06 7.00 7.27 N/A VBFS362F 13.12 15.83 8.85 7.27 N/A VBFS363F 13.12 15.83 8.85 7.27 N/A VBFS364F 17 18.20 12.68 7.57 N/A Non-fusible, Flange Mounted VBNFS361F 9.79 11.78 7.00 7.27 N/A VBNFS362F 9.79 11.78 8.85 7.27 N/A VBNFS363F 9.79 11.78 8.85 7.27 N/A VBNFS364F 10.77 12.00 12.68 7.57 N/A Dimension C for panel mounted switches indicates the minimum width from the left hand edge of the switch mounting pan to the right hand inside surface of the enclosure. 4-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog C Disconnect Switches Type MCS (30-200A) — Switches, Fuse and No Fuse Kits Selection Features ▪ Compact Size ▪ Visible Blade Contacts ▪ Rugged Construction — with a short circuit current rating of 10,000 amps with Class H or 200,000 amps at 600V maximum AC, when fused with Class R or Class J fuses ▪ Available with three operator handle options, allowing flexible placement of switch ▪ Field Installable Auxiliary Contacts ▪ Flexible Fuse Class Configurations ▪ Flange mounted handles meet NFPA79 requirements Type MCS Disconnect Switch with Max-Flex™ handle operator Type MCS Disconnect Switch with fixed-depth, flange-mounted handle Type MCS Disconnect Switch with rotary handle 1. Select the basic switch size you need (30, 60, 100 or 200 ampere). 2. Check the switch selected against the maximum horsepower rating required for your application. “L” or “R” suffix on 4-12 for installation space requirements. 5. Select from the list of handle operators, the type which best suits your application. Handle operators can be selected from the next page. switch catalog numbers denotes left or right-handed mechanism drive. 3. Choose either fuse or no fuse kit from chart below.ng Information 4. Check “Minimum Dimensions” on page Basic Switches Maximum Horsepower Rating, 3 Phase햵 Maximum Voltage Rating Catalog Number Right Hand Catalog Number Left Hand 240 Volts AC Switch Ampere Rating 130 600 MCS603R 160 600 MCS606R 100 600 MCS610R 200 600 MCS620R 480 Volts AC Standard Fuse Time Delay Fuse MCS603L 13 MCS606L 171⁄2 600 Volts AC 250 Volts DC (max)햵 List Price $ 120 15 464.00 150 10 534.00 30 175 20 996.00 60 150 40 1607.00 Standard Fuse Time Delay Fuse Standard Fuse Time Delay Fuse 171⁄2 15 115 171⁄2 15 15 130 15 MCS610L▲ 15 30 25 160 MCS620L▲ 25 60 50 125 Fuse And No Fuse Kits (Includes load base plus line and load fuse clips)햲 Basic Switch Ampere Rating No Fuse Kits Switch Catalog Number For Class H Cu Only햳 Standard Std List Price $ 햲 Std List Price $ Lug Wire Size — — FCJK603 — FCJK606 — — 98.00 — 127.00 — FCRK203 FCRK206 FCRK206 FCRK606 — 98.00 119.00 119.00 154.00 #14 to #4 AWG Cu/AI — — FCK206 87.00 FCK606 127.00 OFCK661▲ 294.00 OFCK661▲ 294.00 — — — — FCJK606 127.00 OFCK661▲ 294.00 OFCK661▲ 294.00 — FCRK206 FCRK606 — 119.00 154.00 — — #14 to #4 AWG Cu/AI — FCK610 FCK610 OFCK620 OFCK620 — 296.00 296.00 562.00 562.00 — FCK610 FCK610 OFCK620 OFCK620 — 296.00 296.00 562.00 562.00 — FCK620 FCK620 — 730.00 730.00 — FCK620 FCK620 — 730.00 730.00 Catalog Number 130 No Fuse MCS603R 30A, 250V or 30A, 600V MCS603L 60A, 250V 60A, 600V TMK606 — — — — 15.10 — — — — — — — — — — — — — — — FCK203▲ FCK206 FCK206 FCK606 160 No Fuse MCS606R 60A, 250V or 60A, 600V MCS606L 100A, 250V 100A, 600V TMK606 — — — — 15.10 — — — — — — — — — — — — — — No Fuse MCS610R 100A, 250V or 100A, 600V MCS610L 200A, 250V 200A, 600V TMK610 — — — — 37.50 — — — — TMK610C — — — — 74.00 — — — — No Fuse MCS620R 200A, 250V or 200A, 600V MCS620L TMK620 — — 77.00 — — TMK620C▲ 156.00 — — — — ▲ Built to order. Allow 6–8 weeks for delivery. 햲 For “copper only” connectors, order as follows: Fusible—order standard switch, standard fuse kit and copper only no fuse kit. Discount Schedule HDSS 햳 햲 Std List Price $ — 67.00 87.00 87.00 127.00 Non-Fusible—order standard switch and copper only no fuse kit. Includes both line and load lugs. Catalog Number For Class R 햲 List Price $ 200 List Price $ Catalog Number Catalog Number 100 Kit Description For Class J 햴 햵 Catalog Number 햴 햴 — 햴 햴 햴 햴 — 햴 햴 — — — — — — — — #14 to #2/0 AWG Cu/AI #6 to 300 kcmil Cu/AI For Class R fuses order Class H kit from this table and the Class R conversion kit from the next page. HP ratings for time delay fuses and for 250V DC also apply to Non-fusible switches. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-11 DISCONNECT SWITCHES Ordering Information 4 ▪ 30, 60, 100 and 200 Ampere Switches ▪ UL Recognized (file # E121152 vol. 1 & 2) and CSA Certified ▪ Simple Mounting — with an integral switch and over center mechanism ▪ Horsepower & load break rated Disconnect Switches Type MCS (30-200A) Accessories Auxiliary Switch Kits Class R Fuse Conversion Kits Contact Arrangement 1 NO/1 NC 2 NO/2 NC Switch Catalog Number Catalog Number List Price $ Catalog Number List Price $ MCS603R MCS603L MCS606R MCS606L MCS610R MCS610L MCS620R MCS620L MCSAKR136 MCSAKL136 MCSAKR136 MCSAKL136 MCSAK116 MCSAK116 MCSAK126 MCSAK126 347.00 347.00 347.00 347.00 348.00 348.00 398.00 398.00 MCSAKR236 MCSAKL236▲ MCSAKR236 MCSAKL236▲ MCSAK216 MCSAK216 MCSAK226 MCSAK226 602.00 602.00 602.00 602.00 603.00 603.00 802.00 802.00 Fuse Clip Rating Catalog Number List Price $ 100A, 600V 200A, 600V SSRK33 SSRK34 54.00 54.00 Fuse Ejector Kits Handle Operators Switch Catalog Number Fuse Ejector Kit Catalog Number List Price $ MCS610 MCS620 FE100▲ FE200▲ 23.00 35.50 DISCONNECT SWITCHES 4 Fixed Depth, Flange Mounted, Types 1, 3, 3R, 12 Switch Catalog Number Complete Handle Mechanism Handle Only Catalog Number List Price $ Catalog Number List Price $ Switch Operator Only Catalog Number List Price $ MCS603R MCS603L MCS606R MCS606L MCS610R MCS610L MCS620R MCS620L FDFS06R FDFS06L FDFS06R FDFS06L FDFS06R FDFS06L FDFS20R FDFS20L 317.00 317.00 317.00 317.00 317.00 317.00 415.00 415.00 FDH10 FDH10 FDH10 FDH10 FDH10 FDH10 FDH20 FDH20 252.00 252.00 252.00 252.00 252.00 252.00 247.00 247.00 FDS06R FDS06L FDS06R FDS06L FDS06R FDS06L FDS20R FDS20L 65.00 65.00 65.00 65.00 65.00 65.00 168.00 168.00 Variable Depth, Flange Mounted Max-Flex™, Types 1, 3, 3R, 12 Switch Catalog Number Complete Handle Mechanism Handle Only Switch Operator Only Cable Only Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ MCS603R MCS603L MCS606R MCS606L MCS610R MCS610L MCS620R MCS620L FHOS06036R FHOS06036L FHOS06036R FHOS06036L FHOS06036R FHOS06036L FHOS20036R FHOS20036L 625.00 625.00 625.00 625.00 625.00 625.00 710.00 710.00 FHOHS FHOHS FHOHS FHOHS FHOHS FHOHS FHOHS FHOHS 311.00 311.00 311.00 311.00 311.00 311.00 311.00 311.00 FHOS06R FHOS06L FHOS06R FHOS06L FHOS06R FHOS06L FHOS20R FHOS20L 161.00 161.00 161.00 161.00 161.00 161.00 222.00 222.00 FHOEC036 FHOEC036 FHOEC036 FHOEC036 FHOEC036 FHOEC036 FHOJC036 FHOJC036 153.00 153.00 153.00 153.00 153.00 153.00 177.00 177.00 RHOS06 RHOS06 RHOS06 RHOS20 76.00 76.00 76.00 125.00 Variable Depth Rotary, Through-The-Door-Mounted, Types 1, 12 Variable Depth MCS603R MCS606R MCS610R MCS620R Shaft Only Variable Depth CRHOS06VD CRHOS06VD CRHOS06VD CRHOS20VD 158.50 158.50 158.50 207.50 CRHOH CRHOH CRHOH CRHOH 51.00 51.00 51.00 51.00 RHOSVD RHOSVD RHOSVD RHOSVD 31.50 31.50 31.50 31.50 MCS Disconnect Switch Panel Space Requirements Panel Space Requirements Minimum Dimensions (inches*) Switch Catalog Number Size 30A/240V MCS603 30A/600V 30A/600V 60A/240V MCS606 60A/600V 60A/600V 100A/240V MCS610 100A/600V 100A/600V 200A/240V MCS620 200A/600V 200A/600V ▲ Built to order. Allow 6–8 weeks for delivery. For Type 4 and 4X applications, order handle only Catalog Number 100A - FDH104 (list price $354.00) 200A - FDH204 (list price $349.00) For Type 4 and 4X applications, order handle only Catalog Number FHOHS4, List Price $432.00 4-12 “A” 6.13 6.13 6.13 6.13 6.13 6.13 7.38 7.38 7.38 9.17 9.17 9.17 “B” 5.52 5.52 5.52 5.52 5.52 5.52 7.59 7.59 7.59 9.00 9.00 9.00 “C” 8.11 10.11 8.48 7.86 10.38 8.35 11.85 13.85 10.6 14.7 17.2 13.32 Fuse Class H, K, R H, K, R J H, K, R H, K, R J H, K, R H, K, R J H, K, R H, K, R J Standard cable length is 36 inches. Alternate lengths are available as follows: Length Amps Cat. No. List Price $ 48" 30–100 FHOEC048 182.00 60" 30–100 FHOEC060 203.00 48" 200 FHOJC048 209.00 60" 200 FHOJC060 239.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog “A” – Dimension is measured from each cross bail pin. “B” – Dimension is measured from line side barrier to load side barrier. “C” – Dimension is measured from line side terminal of switch to load side terminal of fuse load base. For Type 4 and 4X applications, order handle only Catalog Number RHOH4, List Price $150.00 Type 3 and 3R applications, order handle only Catalog Number RHOH, List Price $116.00 Min. enclosure depth from mounting pan to handle mounting surfaces: 30-100A 6.44 Inches 200A 10.93 Inches *For millimeters multiply inches by 25.4. For Discount Schedule HDSS & MCCB Disconnect Switches Type CFS Compact Fusible Switches Features and Ordering Information Features ▪ 30–400A ratings ▪ UL Listed & CSA Certified ▪ IEC 60 947-3 Certified & CE marked ▪ Door mounted rotary handles with defeatable cover interlock ▪ Meets UL requirements for both main and branch circuit applications ▪ Compact size ▪ 50 or 100KA with Class CC fuses or up to 200KA with Class J fuses ▪ Load break and horsepower rated ▪ Quick make and break operation ▪ All handles are padlockable with up to (3) padlocks with 5/16" hasps in the OFF position Shaft Handle CFS362J CFSS10200H CFSH10B4 ▪ Handles are available in Type 1, 3R, 4/4X & 12 ratings ▪ NFPA 79 field installed kits are available Lugs/Accessories 4 Switch ▪ Catalog number CFS361C5, CFS361J5 & CNFS361 can be DIN-rail mounted and can be either front or side operated with standard rotary handles DISCONNECT SWITCHES CFSL200 Ordering Information 1. Select the panel mounted switch required based on Ampere, HP and AIC requirements. Switches with a right hand mechanism are standard. 30-100A switches with a left hand mechanism are available. 2. Select handle based on environmental rating required. 3. Select operating shaft (200 or 400mm in length). For enclosure depths of 9.0" or less from panel mounting surface to inside of door use 200mm long shafts. For deeper enclosures use 400mm long shafts. 30A 50kA switches can be used in 10" deep enclosures (panel to inside of door) with 200mm shaft and CFSH5 handles. Note: Be sure to check shaft and handle compatibility with the switch selected by using the information provided in the selection tables. 4. Line & load lugs are provided as standard on 30 & 60A switches. Terminal kits are available for 100–400A switches if needed. 5. Auxiliary contacts are available if needed as follows: A. 30A, 50kA switch CFS361C5 and non-fusible 30A switch CNFS361 will accept up to (4) aux contacts without an aux contact holder. B. 30A, 50kA switch CFS361J5 will accept up to (2) aux contacts without an aux contact holder. If more than (2) aux contacts are required order aux contacts PLUS aux contact holder kit CFSAUXH1. C. For all 100 or 200kA 30–400A switches order the aux contacts required PLUS aux contact holder kit CFSAUXH2. 6. If non-fusible switch is required order a shorting bar for 60-600A switches or catalog number CNFS361 for 30A. 7. All switches are supplied with line shields as standard. 30, 60 & 400A switches are also supplied with load shields. Load side terminal shroud kits are available for 100 & 200A switches. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-13 Disconnect Switches Type CFS Compact Fusible Switches Switch and Handle Selection Fusible Switches, 3-Pole 600V AC Max, 250V DC Max Max Horsepower Ratings Switch Ampere Rating Catalog Number Fuse Provisions Provided List Price $ 240V 3Ø AC 480V 3Ø AC 600V 3Ø AC 250V DC 20 20 20 20 20 50 75 150 350 5 5 5 5 5 10 20 40 50 20 50 75 5 10 20 AC Short Circuit Rating Standard - with Right Hand Mounted Mechanism 30 30 30 30 30 60 100 200 400 CFS361C5 361.00 CFS361J5 376.00 CFS361C 382.00 CFS361J 424.00 CNFS361 336.00 CFS362J 488.00 CFS363J 678.00 CFS364J 1710.00 CFS365J 2462.00 Class CC Class J Class CC Class J None Class J 7.5 7.5 7.5 7.5 7.5 15 30 60 125 15 15 15 15 15 30 60 125 250 50kA 50kA 100kA 200kA 50kA CFS361J5 200kA DISCONNECT SWITCHES 4 Optional - with Left Hand Mounted Mechanism 30 60 100 CFS361JL CFS362JL CFS363JL 452.00 511.00 710.00 Class J 7.5 15 30 15 30 60 200kA Operating Shafts Shaft Length In. (mm) 7.9 (200) Catalog Number CFSS5200 List Price $ 34.00 CFSS5400 36.00 CFSS5200H 34.00 7.9 (200) CFSS5400H 36.00 15.7 (400) CFSS10200H 36.00 7.9 (200) CFSS10400H 38.50 15.7 (400) 15.7 (400) Switch & Handle Compatibility 5mm x 5mm for use with CFS361C5, CFS361J5 & CNFS361 switches & with “CFSH5” handles only 5mm x 5mm for use with all “CFSH10” handles & with CFS361C5, CFS361J5 & CNFS361 switches only 10mm x 10mm for use with all “CFSH10” handles & with all switches except CFS361C5, CFS361J5 & CNFS361 CFSS5400 CFSS5200 Rotary Operating Handles—Door Mounted (for use with 50kA CFS361C5 & CFS361J5 switches only) Type 1, 3R & 12 Catalog Number CFSH5B12 List Price $ 114.00 Color Black CFSH5R12 114.00 Yellow & Red Operating Shaft Compatibility CFSS5200 OR CFSS5400 (5mm x 5mm) Rotary Operating Handles—Door Mounted (for use with all operating shafts except CFSS5200 & CFSS5400 and with all CFS switches) Catalog Number List Price $ 12 Color CFSH10B12 137.00 Black CFSH10R12 137.00 Yellow & Red Type 1, 3R & CFSH10BL12 143.00 Black CFSH10RL12 143.00 Yellow & Red Description CFSH5B12 Heavy duty pistol grip (3.78" long) Heavy duty pistol grip (6.00" long) Type 1, 3R, 4/4X & 12 CFSH10B4 149.00 Black CFSH10R4 149.00 Yellow & Red CFSH10BL4 162.00 Black CFSH10RL4 162.00 Yellow & Red Line Heavy duty pistol grip (3.78" long) Heavy duty pistol grip (6.00" long) and load lugs included. and load lugs are not included. Order from table on next page if required. DC HP rating shown requires (2) poles to be connected in series. Line 4-14 DC HP rating shown requires (3) poles to be connected in series. numbers CFS361C5 & CFS361J5 accept 5mm x 5mm operating shafts. All others accept 10mm x 10mm operating shafts. Catalog Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Compact pistol grip design (3.25" long) with defeatable cover interlock. Cover can be opened when handle is padlocked in the OFF position. Defeatable cover interlock provided. Cover cannot be opened when handle is padlocked in the OFF position. Catalog number CNFS361 is a non-fusible switch. Discount Schedule HDSS Disconnect Switches Type CFS Compact Fusible Switches CFSAUXH2, CFSAUXINO & CFSAUXINC Accessories CFSL100, 200 & 400 Type CFS Fusible Switch Accessories Catalog Number List Price $ Description 4 Terminals 71.00 100A Lug Kit (6 lugs per kit) CFSL200 100.00 200A Lug Kit (6 lugs per kit) CFSL400 276.00 400A Lug Kit (6 lugs per kit) DISCONNECT SWITCHES CFSL100 Shorting Bars (no fuse kits) CFSSB60 35.50 60A Shorting Bar Kit (3 links per kit) CFSSB100 50.00 100A Shorting Bar Kit (3 links per kit) CFSSB200 71.00 200A Shorting Bar Kit (3 links per kit) CFSSB400 103.00 400A Shorting Bar Kit (3 links per kit) Auxiliary Contacts CFSAUXH1 52.00 Aux Contact Holder (30A 50kA Sws) CFSAUXH2 52.00 Aux Contact Holder (30–400 100 & 200kA SW) CFSAUX1NO 28.00 Aux Contact 1 NO (30–400A Sws) CFSAUX1NC 28.00 Aux Contact 1 NC (30–400A Sws) CFSAUXH1 & CFSAUXINO Terminal Shrouds CFSTS100 84.00 100A Shroud Kit CFSTS200 134.00 200A Shroud Kit CFSTS400 155.00 400A Shroud Kit Padlock Kit (when door is open) CFSPLK 100.00 Shaft Padlocking Kit for 30A Compact Switch NFPA 79 Kits Kits provide an operating shaft suitable for use with all heavy duty handles (not for use with CFSH5B12 or CFSH5R12). Kits also provide an internal operating handle & an internal OFF padlocking provision. CFSNFPA1 207.00 For use with CFS361C5, CFS361J5 & CNFS361 CFSNFPA2 343.00 For use with CFS361J - CFS365J & CFS361C CFS5B100 – 400 Note: CFSNFPA2 cannot be used in combination with CFSAUX1NO or CFSAUX1NC auxiliary contacts. Supplied as standard on 30 & 60A switches. CFS361C5 and CNFS361 will accept (4) aux contacts without an aux contact holder. CFS361J5 will accept (2) aux contacts without an aux contact holder. ON ALL OTHER SWITCHES CFSAUXH2 IS REQUIRED TO MOUNT AUX CONTACTS. Discount Schedule HDSS Supplied as standard on all but 30A compact switches. 12.6 inch (320 mm) long operating shaft included. 11.3 inch (288 mm) long operating shaft included. Line side terminal shrouds supplied with switch. Supplied on both line and load side with CFS365J switch. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-15 Disconnect Switches Type CFS Compact Fusible Switches Dimensions and Technical Characteristics UL & CSA Technical Characteristics Catalog Number DISCONNECT SWITCHES 4 Amp Rating Max AC Volts Electrical Endurance Max Horsepower Ratings 240V 3Ø AC 480V 3Ø AC 600V 3Ø AC 250V DC AC Short Circuit Rating Fuse Type (Class) Electrical Endurance Mechanical Endurance Shaft Cross Section Operating Torque (lb. In.) Aux Contacts Nema Rating AC Nema Rating DC CFS361C5햲 CFS361J5 CFS361C CFS361J & CFS361JL CFS362J & CFS362JL CFS363J & CFS363JL CFS364J CFS3615J 30 600 6000 30 600 6000 30 600 6000 30 600 6000 60 600 6000 100 600 6000 200 600 6000 400 600 1000 7.5 15 20 5햳 50kA CC 6000 10000 5mm 21 7.5 15 20 5햳 50kA J 6000 10000 5mm 21 7.5 15 20 5햳 100kA CC 6000 10000 10mm 53 7.5 15 20 5햳 200kA J 6000 10000 10mm 88 15 30 50 10햳 200kA J 6000 10000 10mm 88 30 60 75 20햳 200kA J 6000 10000 10mm 88 60 125 150 40햴 200kA J 6000 8000 10mm 106 125 250 350 50햴 200kA J 1000 6000 10mm 132 A600 N600 A600 N600 A600 N600 A600 N600 A600 N600 A600 N600 A600 N600 A600 N600 CFS361J5 CFS361C CFS361J & CFS361JL CFS362J & CFS362JL CFS363J & CFS363JL CFS364J CFS3615J IEC Technical Characteristics Catalog Number CFS361C5햵 Rating Insulation Voltage Ui Rated Impulse Voltage (Uimp) Operational Current Ie 400V AC (AC22A & AC23A) 690V AC (AC22A & AC23A) Motor Power (kW) 400V AC 500V AC 690V AC Max Peak (kA peak) let though current Cu cable sie (mm2) 800 800 750 750 750 750 750 800 8kV 8kV 8kV 8kV 8kV 8kV 8kV 8kV 32 32 32 32 63 100 200 400 32 32 32 32 63 100 200 400 15 18.5 25 15 18.5 25 15 18.5 25 15 18.5 25 30 40 55 51 63 90 100 140 185 220 220 220 5.5 6 5.5 6 7.6 6 17.6 6 17.6 10 22 25 32 50 36 185 Panel Space Requirements Wire Ranges Line & Load Lugs Switch Ampere Rating UL Approved Wire Size (75°C) Mechanical Wire Range of Lug (75°C) Catalog Number CFS361C5 30 4.56 (116) 3.78 (96) 6.00 (152) 30 60 100 200 #10 Cu #6 Cu #3 Cu #3/0 Cu (2) 300 kcmil Al or (2) 4/0 Cu #14–10 Cu #10–3 Cu #14–2/0 Cu/Al #6–3/0 Cu/Al CFS361J5 30 4.56 (116) 4.15 (105) 6.00 (152) CFS361C 30 5.88 (149) 5.62 (143) 7.00 (178) CFS361J & CFS361JL 30 5.88 (149) 6.75 (171) 7.00 (178) (2)#2–600 kcmil Cu/Al CFS362J & CFS362JL 60 5.88 (149) 6.75 (171) 7.00 (178) CFS363J & CFS363JL 100 7.19 (183) 8.25 (210) 7.00 (178) CFS364J 200 8.13 (206) 9.44 (240) 8.00 (203) CFS365J 400 14.94 (363) 11.94 (303) 8.00 (203) 400 햲 Ratings also apply to catalog number CNFS361 except the 50kA AIC rating applies when switch is protected by Class J or CC 30A max. fuses. 햳 DC HP rating requires (2) poles to be connected in series. 4-16 햴 햵 Ampere Rating DC HP rating requires (3) poles to be connected in series. Ratings also apply to catalog number CNFS361. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Dimensions Inches (mm) Height Width 햶 Depth햶 Minimum dimension from mounting surface to inside of cover. Dimensions shown can be decreased if aux contacts are not required. Disconnect Switches Type VB Panelboard Units Features Vacu-Break ® 21/2" Specifications Application VB Panelboard Switches are intended for use in applications where: 1. Rugged constructions, reliable performance, continuity of service and ease of maintenance are emphasized, or 2. Available fault currents higher than 10,000A are likely to be encountered, in manufacturing plants, mass production industries and commercial, institutional and other large buildings served by network systems or transformers of high capacities. Maximum Withstand Ratings — 240V AC H, K Fuses R Fuses J Fuses 10,000 200,000 — 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 — — — — — — units will not accept Class R or J fuse clip kits and are rated 10,000 AIC max. L Fuses — — — — — — — — — — 200,000 100,000 T Fuses — — — — 200,000 200,000 200,000 200,000 200,000 200,000 200,000 — Maximum Withstand Ratings — 600V AC H, K Fuses R Fuses J Fuses 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 200,000 200,000 10,000 — 200,000 10,000 200,000 200,000 10,000 200,000 200,000 — — — — — — L Fuses — — — — — — — — — — 200,000 100,000 T Fuses — — — 200,000 200,000 200,000 200,000 — 200,000 200,000 200,000 — Ratings are for 600V switches and fuses when used on a 240V max. AC system. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-17 DISCONNECT SWITCHES Switch Rating 1130–30 1130–60 1160–60 1160–100 1100 1100–100 1200 1200–200 1400 1600 1800 1200 installation and are designed with openings large enough to accommodate removable lugs (200 Amps and larger units). High Pressure Spring Reinforced Copper Fuse Clips — Provided extra pressure at the contact points. Fuse clips are removable from the front in 71⁄2" and 10" units and from the rear of 5" units. Voidable Cover Interlock — Permits only authorized personnel to void the door interlock and open door with switch “on.” “Fool proof” mechanism will not permit door to be closed unless handle is in the correct position. 4 Exclusive Clampmatic Arc Control — Hazardous switching arcs are safely confined and controlled in the Vacu-Break chamber. NEMA Phasing — All line connections are phased as per NEMA Standards, i.e., left to right and top to bottom as you face the unit. Pressure Terminal Connectors — Suitable for aluminum or copper (100 Amps or larger). All Terminal Connectors 200 Amps and larger are removable. Connection Screws — Bullet nosed for positive location and seating of screw. Quick-Make Quick-Break — Assured by design of cam mechanism and powerful springs. Positive operation in “ON”or “OFF” position results from design of the cross arm and Vacu-Break head linkage. Easy Mounting — Mounting feet have captive bullet nosed screws added, which seat quickly and positively, reducing installation time. Padlocking Member — Provides locking of handle in the “ON”or “OFF” position. Fibre End Barriers — Insulated End Barriers prevent damage to wire during General Short Circuit Withstand Ratings Suitable for use on systems capable of delivering not more than 200,000 RMS symmetrical amperes of fault current when Class J or R fuses are installed. 1200A switches are the exception, which are suitable for use on circuits capable of delivering not more than 100,000 RMS symmetrical amperes of fault current when Class L fuses are installed. Also, 100–800A switches with Class T fuses and field adapter kit, which are 200,000 RMS symmetrical rated. Fuses Fusible switches will accept the following UL Class fuses: Class H Class K Class R or J with proper adapter kit Class L — 800 and 1200A switches Class T — 100–800 switches with proper adapter kit Cover Interlocks Voidable cover interlocks standard on all switches. Prevents cover from being opened when switch is in the “ON” position. UL Listing Listed by UL under file #E6849 as miscellaneous switches and also suitable for use as service equipment (where applicable). Meets UL98 standard for enclosed and deadfront switches. NEMA Specifications Meets NEMA standard KS-1-1990 for type HD switches. Federal Specifications Meets previous federal specifications W-S-865C for heavy duty switches (Type HD) Type 1 switches — general purpose enclosed (Type 1). Disconnect Switches Type VB Panelboard Units Selection Fusible Units For SB1, SB2 Switchboards and F1, F2 Panelboards Catalog Numbering System V 7 E 3 2 3 3 ▲ ▲ ▲ ▲ ▲ ▲ ▲ Vacu-Break Unit Width 2 = 12" 7 = 17" M = 17" (Main) B = 5" E = 71⁄2" F = 10" H = 15" 2 = 60A 3 = 100A 4 = 200A Height A = 21⁄2" S = 18.75" Number of Poles 2 3 Voltage Rating 2 = 240V 6 = 600V Amperes DISCONNECT SWITCHES 4 0 = Single Unit Double 1 = 30A Ampere Rating 1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600A Example: V7E3233 = Vacu-Break Unit, 17" Wide, 71⁄2" High, 3-Pole, 240 Volts, Double Branch Unit with 100 Amp Rating each side. Suffix letters MS indicate Main Switch. Vacu-Break ® Fusible Units 2-Pole , 12" Wide 240V AC, 250V DC Ampere Rating Unit Height (inches) Unit Depth (inches) Horsepower Rating 240 Volt AC Standard Maximum 130–30 21⁄2 41⁄2 011⁄2 1 250 Volt DC Lug Wire Range (Cu/AI) and Cables Per Pole Unit Weight (pounds) Catalog Number List Price $ 03 05 (1)–#14 to #8 (Cu Only) 15 V2A2211LR ■ 588.00 130–30 5 4 ⁄2 011⁄2 03 05 (1)–#14 to #8 19 V2B2211LR ■ 758.00 130–60 5 41⁄2 011⁄2 –3 03–10 05–10 (1)–#14 to #4 19 V2B2212LR ■ 837.00 160–60 5 41⁄2 03 10 10 (1)–#14 to #4 19 V2B2222LR ■ 837.00 100 71⁄2 63⁄4 071⁄2 15 20 (1)–#10 to #1/0 14 V2E2203LR ■ 671.00 200 71⁄2 63⁄4 15 — 40 (1)–#6 to 250 kcmil 19 V2E2204LR ■ 1175.00 3-Pole Ampere Rating 240V AC, 250V DC Unit Height (inches) Unit Depth (inches) Horsepower Rating 240 Volt AC Standard Maximum Unit Weight (pounds) Lug Wire Range (Cu/AI) and Cables Per Pole Catalog Number List Price $ Branch Circuits, 12" Wide Units 21⁄2 41⁄2 03 071⁄2 (1)–#14 to #8 (Cu Only) 5 V2A3211■ 130–30 5111 1 4 ⁄2 03 071⁄2 (1)–#14 to #8 9 V2B3211■ 130–30 5111 41⁄2 03 071⁄2 (1)–#14 to #8 9 V2B3211R ■ 1007.00 130–60 5111 41⁄2 03–71⁄2 071⁄2–15 (1)–#14 to #4 9 130–60 5111 41⁄2 03–71⁄2 071⁄2–15 (1)–#14 to #4 9 V2B3212■ V2B3212R ■ 1007.00 160–60 5111 41⁄2 071⁄2 15 (1)–#14 to #4 9 V2B3222 5111 1 4 ⁄2 071⁄2 15 (1)–#14 to #4 9 V2B3222R ■ 100 71⁄2 63⁄4 15 30 (1)–#10 to #1/0 14 V2E3203 758.00 200 10 11 63⁄4 25 60 (1)–#6 to 250 kcmil 21 V2F3204 1473.00 50 21 V2F3204MS■ 1473.00 130–30 160–60 652.00 943.00 943.00 943.00 1007.00 Main Switch , 12" Wide Units, Back Connected 200 10 63⁄4 25 For inches / millimeters conversion, multiply inches by 25.4. ■ Built to order. Allow 2–3 weeks for delivery. These units are available in LR (left, right) connection figurations only. 4-18 This unit is not a Vacu-Break unit, but rather operates on a sliding contact, double break principle. Rated 10,000 AIC max. with either Class H or K fuses. Will not accept Class R fuse clip kits. Units set up for R-fuse application only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog For 2-pole main switch (200A), use 3-pole main switch Vacu-Break unit. furnished with spade type bolted terminal pads. Load-side Discount Schedule VBSS Disconnect Switches Type VB Panel Units Selection Vacu-Break ® Fusible Units for SB1, SB2 Switchboards and F1, F2 Panelboards Ampere Rating 2-Pole , Unit Height (inches) Unit Depth (inches) Horsepower Rating 240 Volt AC Standard Maximum 250 Volt DC Lug Wire Range (Cu/AI) and Cables Per Pole Unit Weight (pounds) Catalog Number Branch Circuits, 17" Wide Units List Price $ 240V AC, 250V DC 30–30 121⁄2 63⁄4 011⁄2 003 05 (1)–#14 to #8 (Cu Only) 15 V7A2211_ _■ 652.00 30–30 15 63⁄4 011⁄2 003 05 (1)–#14 to #8 19 V7B2211_ _❍ 837.00 30–30 15 63⁄4 011⁄2 003 05 (1)–#14 to #8 19 V7B2211__R 933.00 30–60 15 63⁄4 011⁄2 –3 003–10 05–10 (1)–#14 to #4 19 V7B2212LR■ 931.00 30–60 15 63⁄4 011⁄2 –3 003–10 05–10 (1)–#14 to #4 19 V7B2212LRR■ 994.00 60–60 15 63⁄4 03 010 10 (1)–#14 to #4 19 V7B2222_ _ 931.00 60–60 15 63⁄4 03 010 10 (1)–#14 to #4 19 V7B2222__R 994.00 60–100 171⁄2 63⁄4 03–71⁄2 010–15 10–20 (1)–#10 to #1/0 18 V7E2223LR■ 1090.00 100 –100 171⁄2 63⁄4 071⁄2 015 20 (1)–#10 to #1/0 20 V7E2233_ _❍ 1090.00 100 17 ⁄2 6 ⁄4 07 ⁄2 015 20 (1)–#10 to #1/0 14 V7E2203LR 200 171⁄2 63⁄4 15 — 40 (1)–#6 to 250 kcmil 21 V7E2204_ _❒ 1241.00 400 15 101⁄2 — — 50 (1)–#1/0 to 500 kcmil or (2)–#1/0 to 300 kcmil 63 V7H2205LR 2947.00 V7H2206LR■ 3410.00 3 1 15 10 ⁄2 1 — — — (2)–#4/0 to 500 kcmil 63 200 171⁄2 400 600 240V AC, 250V DC 63⁄4 15 — 40 21 V7E2204MS■ 1241.00 15 101⁄2 — — 50 63 V7H2205MS 2947.00 15 101⁄2 — — — 63 V7H2206MS 3-Pole, Branch Circuits, 17" Wide Units 30–30 121⁄2 63⁄4 03 0071⁄2 — (1)–#14 to #8 (Cu Only) 15 V7A3211 30–30 15 63⁄4 03 0071⁄2 — (1)–#14 to #8 19 V7B3211 30–30 15 63⁄4 03 0071⁄2 — (1)–#14 to #8 19 V7B3211R 30–60 15 63⁄4 03–71⁄2 0071⁄2–15 — (1)–#14 to #4 19 V7B3212 30–60 15 3 6 ⁄4 03–7 ⁄2 0071⁄2–15 — (1)–#14 to #4 19 V7B3212R 60–60 15 63⁄4 071⁄2 015 — (1)–#14 to #4 19 V7B3222 60–60 15 63⁄4 071⁄2 015 — (1)–#14 to #4 19 V7B3222R 60 171⁄2 63⁄4 071⁄2 1 3410.00 240V AC 721.00 991.00 1052.00 991.00 1052.00 991.00 1052.00 015 — (1)–#14 to #4 13 V7E3202 834.00 60–100 17 ⁄2 6 ⁄4 071⁄2–15 015–30 — (1)–#10 to #1/0 18 V7E3223 1296.00 100 –100 171⁄2 63⁄4 15 030 — (1)–#10 to #1/0 20 V7E3233 1296.00 100 –100 171⁄2 63⁄4 15 030 — (1)–#10 to #1/0 20 V7E3233R 1509.00 100 171⁄2 63⁄4 15 030 — (1)–#10 to #1/0 14 V7E3203 200 –200 10 63⁄4 25 060 — (1)–#6 to 250 kcmil 40 V7F3644 200 –200 10 63⁄4 25 060 — (1)–#6 to 250 kcmil 40 V7F3244R 3334.00 200 10 63⁄4 25 060 — (1)–#6 to 250 kcmil 21 V7F3204 1519.00 400 15 101⁄2 50 125 — (1)–#1/0 to 500 kcmil or (2)–#1/0 to 300 kcmil 63 V7H3205 3410.00 400 15 101⁄2 50 125 — (1) 250 to 750 kcmil or (2) 1/0 to 300 kcmil 63 V7H3205750 3410.00 600 15 101⁄2 75 200 — (2)–#4/0 to 500 kcmil 63 V7H3206 1 3 3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Top Feed, Front Connected) 834.00 3192.00 3835.00 240V AC 400 18.75 103⁄8 50 125 — — — VMS325T 600 18.75 103⁄8 75 200 — — — VMS326T 3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Bottom Feed, Front Connected) 3410.00 3835.00 240V AC 400 18.75 103⁄8 50 125 — — — VMS325B 600 18.75 103⁄8 75 200 — — — VMS326B 3-Pole, Main Switch, 17" Wide Units, Back Connected 3410.00 3835.00 240V AC 100 171⁄2 63⁄4 15 030 — 14 V7E3203MS 959.00 200 10 63⁄4 25 060 — 21 V7F3204MS 1519.00 400 15 101⁄2 50 125 — 63 V7H3205MS 3410.00 75 200 — 63 V7H3206MS 3835.00 600 15 1 10 ⁄2 For inches / millimeters conversion, multiply inches by 25.4. ■ Built to order. Allow 2–3 weeks for delivery. ❒ MR suffix. Built to order. Allow 2–3 weeks for delivery. ❍ MR, LM suffix. Built to order. Allow 2–3 weeks for delivery. Discount Schedule VBSS Order 2-pole branch circuit units by adding appropriate connection designation LM, LR or MR (indicating Left, Middle and Right, facing the panel). This unit is not a Vacu-Break unit, but rather operates on a sliding contact, double break principle. Rated 10,000 AIC max. with either Class H or K fuses. Will not accept Class R fuse clip kits. MR not available. Available as Type LR connection designation only. Switches set up for R-fuse applications only. Rated 600 Volts but factory configured to accept 250V Class H, K or R fuses. Field convertible for Class J fuses for 600V applications. Field convertible for 300V Class T fuse with TFAK42 kit. Load-side furnished with spade type bolted terminal pads. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-19 DISCONNECT SWITCHES 2-Pole, Main Switch, 17" Wide Units, Back Connected 863.00 4 600 1 Disconnect Switches Type VB Panel Units Selection Vacu-Break ® Fusible Units For SB1, SB2 Switchboards and F1, F2 Panelboards Ampere Rating Unit Height (inches) Unit Depth (inches) Horsepower Rating 480 Volt AC 600 Volt AC Standard Maximum Standard Maximum Lug Wire Range (Cu/AI) and Cables Per Pole Unit Weight (pounds) 2-Pole, Branch Circuits, 17" Wide Units Catalog Number List Price $ 600V AC, 250V DC 1130–30 171⁄2 63⁄4 003 0071⁄2 003 010 (1)–#14 to #8 14 V7E2611LR ■ 1063.00 1130–60 171⁄2 63⁄4 003–5 0071⁄2–20 003–5 020–25 (1)–#14 to #4 14 V7E2612LR ■ 1063.00 1160–60 171⁄2 63⁄4 005 020 010 025 (1)–#14 to #4 14 V7E2622LR ■ 1063.00 1100 171⁄2 63⁄4 010 020 015 040 (1)–#10 to #1/0 14 V7E2603LR ■ 753.00 1200 10 63⁄4 025 050 030 050 (1)–#6 to 250 kcmil 21 V7F2604LR ■ 1657.00 1400 15 101⁄2 — — — — (1)–#1/0 to 500 kcmil 63 V7H2605MR◆ 3410.00 3-Pole, Branch Circuits, 17" Wide Units 600V AC, 250V DC 63⁄4 005 015 0071⁄2 020 (1)–#14 to #8 14 V7E3611 1364.00 1130–30 171⁄2 63⁄4 005 015 0071⁄2 020 (1)–#14 to #8 14 V7E3611R 1568.00 1130 171⁄2 63⁄4 005 015 0071⁄2 020 (1)–#14 to #8 14 V7E3601 931.00 1130–60 171⁄2 63⁄4 005–15 015–30 0071⁄2–15 020–50 (1)–#14 to #4 14 V7E3612 1364.00 171⁄2 63⁄4 4 171⁄2 1160–60 015 030 015 050 (1)–#14 to #4 14 V7E3622 1364.00 1160–60 17 ⁄2 63⁄4 015 030 015 050 (1)–#14 to #4 14 V7E3622R 1568.00 DISCONNECT SWITCHES 1130–30 1160 171⁄2 63⁄4 015 030 015 030 (1)–#14 to #4 14 V7E3602 931.00 1160–100 171⁄2 63⁄4 015–25 030–60 015–30 050–75 (1)–#10 to #1/0 18 V7E3623 1915.00 1100–100 171⁄2 63⁄4 1 025 060 030 075 (1)–#10 to #1/0 20 V7E3633 1915.00 1100–100 17 ⁄2 63⁄4 025 060 030 075 (1)–#10 to #1/0 20 V7E3633R 2057.00 1100 171⁄2 63⁄4 025 060 030 075 (1)–#10 to #1/0 14 V7E3603 1200–200 10 63⁄4 050 125 060 150 (1)–#6 to 250 kcmil 40 V7F3644 J 3192.00 1200 10 63⁄4 050 125 060 150 (1)–#6 to 250 kcmil 21 V7F3604 1736.00 1200 10 63⁄4 050 125 060 150 (1)–#6 to 250 kcmil 21 V7F3604 R 1808.00 1 400 15 101⁄2 100 250 125 350 (1)–#1/0 to 500 kcmil or (2)–#1/0 to 300 kcmil 63 V7H3605 4033.00 1 400 15 101⁄2 100 250 125 350 (1)–250 to 750 kcmil or (2)–#1/0 to 300 kcmil 63 V7H3605750 4033.00 150 400 200 500 (2)–#4/0 to 500 kcmil 63 V7H3606 4164.00 1600 1 15 1 10 ⁄2 3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Top Feed, Front Connected) 931.00 600V AC, 250V DC 1400 18.75 103⁄8 100 250 125 350 — VMS365T 4033.00 1600 18.75 103⁄8 150 400 200 500 — VMS366T 4164.00 3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Bottom Feed, Front Connected) 600V AC, 250V DC 1400 18.75 1711⁄16 100 250 125 350 — VMS365B 4033.00 1600 18.75 1711⁄16 150 400 200 500 — VMS366B 4164.00 3-Pole, Main Switch, 17" Wide Units, Back Connected 600V AC, 250V DC 1100 171⁄2 163⁄4 125 150 130 150 14 1200 10 163⁄4 150 125 160 150 21 V7E3603MS■ V7F3604MS■ 1736.00 931.00 1400 15 101⁄2 100 250 125 350 63 V7H3605MS 4033.00 1600 15 101⁄2 150 400 200 500 63 V7H3606MS 4164.00 3-Pole, Switchboard Units, 21" Wide Units, Front Connected 600V AC, 250V DC 1800 25 12 3⁄4 200 500 250 500 — 160 1200 25 12 3⁄4 — — — — — 160 VF357TL or BL❍ VF358TL or BL 3-Pole, Switchboard Units, 21" Wide, Back Connected 9327.00 9568.00 600V AC, 250V DC 1800 25 12 3⁄4 200 500 250 500 — 160 VB357TL or BL■ 8573.00 1200 25 12 3⁄4 — — — — — 160 VB358TL or BL■ 8993.00 ■ Built to order. Allow 2–3 weeks for delivery. ◆ MR suffix only is available and built to order. Allow 2–3 weeks for delivery. ❍ BL suffix. Built to order. Allow 2–3 weeks for delivery. Catalog number for 2-pole branch circuit units indicate connection designation LM, LR or MR (indicating Left, Middle and Right, facing the panel). 4-20 Unit configured to accept class J fuses only. Also accepts 300V Class T fuses when used with TFAK42 adapter kit. furnished with spade type bolted terminal pads. Suffix “T” or “TL” indicates Top Feed. Suffix “B” or “BL” indicates Bottom Feed. Back connected units are also available. Substitute the letter “B” (back connected) for the letter “F” (front connected) in the prefix of the catalog number. All other features are identical. Load-side Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Available Switches Available as Type MR designation only. set up for R-fuse applications only. as Type LR designation only. Discount Schedule VBSS Disconnect Switches Type VB Panelboard Units, Accessories Extension Kits To extend Vacu-Break unit’s depth, order the extension kit which meets the specifications of the unit to be extended. Specify by catalog number from the table below. Selection Unit Type Unit Height (inches) Normal Unit Depth Extended Unit Depth (inches) (inches) Catalog Number V2A 12 1⁄2 4 9⁄16 16 3⁄4 W43000■ 41.50 V2B 15 4 9⁄16 16 3⁄4 W43002 41.50 V7A 12 1⁄2 6 3⁄4 10 1⁄2 W48762 114.00 V7B 15 6 3⁄4 10 1⁄2 W48763 121.00 V7E 17 1⁄2 6 3⁄4 10 1⁄2 W48764 154.00 V7F 10 6 3⁄4 10 1⁄2 W48765 181.00 List Price $ Fuse Adapter Kits Class R and Class J Fuse Kits are single unit part numbers. Order (2) kits for dual units. Class T Fuse Kits are single pole part numbers. Order (3) kits for a 3-pole unit. To order the kit which meets the specifications of the unit to be changed, specify by catalog number from the tables below. 240 Volt Fuse Adapter Kits Class R Kits Class T Kits Class J Kits Class T Kits Catalog Number Catalog Number List Price $ Switch Amperage Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Class R Kits Catalog Number 130 햳 Factory Inst. — — — — 130 W56623 85.00 W49832 163.00 — 160 W56628 91.00 W49829 163.00 — — 160 W56629 85.00 W49830 163.00 — 100 W55365 61.00 W49827 131.00 TFAK32 76.00 100 W55365 61.00 W49828 131.00 TFAK35 120.00 200 W55366 61.00 W49819 131.00 TFAK42 102.00 200 W55366 햴 61.00 W49818 햲 163.00 TFAK45 143.00 400 W55367 91.00 W49814 330.00 TFAK52 102.00 400 W55367 91.00 W49816 395.00 TFAK55 151.00 600 W55368 91.00 W49813 459.00 TFAK62 120.00 600 W55368 91.00 W49815 330.00 TFAK65 174.00 800 — — — TFAK75 238.00 List Price $ — — List Price $ — — Vacu-Break Connecting Strap Kits For Panelboards and Switchboards Ampere Rating 240V Unit Height (inches) 600V Unit Height (inches) S4/F1, FPP (10" Deep) Strap Kit 130–30 12.5 — F602 130–30 15 17.5 F657 130-60 15 17.5 160–60 15 17.5 160-100 17.5 100-100 S5/F2 (12.75" Deep) Strap Kit List Price $ SB1, SB2, SB3, FC-20, FC-1 VB-5, VB-6, Strap Kit 46.00 F602D 210.00 — — 46.00 F657D 254.00 VB657 302.00 F657 46.00 F657D 254.00 VB657 302.00 F657 46.00 F657D 254.00 VB657 302.00 17.5 F657 46.00 F657D 254.00 VB657 302.00 17.5 17.5 F657 46.00 F657D 254.00 VB657 302.00 100 17.5 17.5 F657 46.00 F657D 254.00 VB657 302.00 200 17.5, 10 17.5, 10 F671 70.00 F671D 393.00 VB671 471.00 200–200 10 10 F672 430.00 F672D 430.00 — — 400 15 15 — — — — VB6150 211.00 600 15 15 — — F6150D 186.00 VB6150 211.00 For inches / millimeters conversion, multiply inches by 25.4. 햲 For ■ Built to order. Allow 2–3 weeks for delivery. 햳 5˝ Discount Schedule VBSS List Price $ 200 A single units only. Dual units are suitable for Class J only, when used above 240V. unit height switches only. 햴 For single units only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-21 DISCONNECT SWITCHES Switch Amperage 4 List Price $ 600 Volt Fuse Adapter Kits Class J Kits Disconnect Switches Type HCP Switchboard Units, Accessories Features ▪ ▪ UL Listed under file number E6849 Vol 1, Sect. 8 ▪ 400-1200A ratings ▪ Visible contacts ▪ Field installable shunt trip and auxiliary switch accessory kits ▪ Installs in existing Siemens switchboards and power panelboards ▪ Suitable for use on systems with up to 200,000A available fault current, RMS symmetrical when equipped with Class J or Class L fuses ▪ ▪ ▪ ▪ Selection Group mounts with other 30A through 600A switches, and 100 through 1200 amp frame breakers Allows 800A and 1200A switches in standard 38" wide distribution sections in either main or branch configurations 16 1⁄4" mounting height is the smallest 1200A design in the industry, allowing up to 4 units in one vertical section Field reversible horizontal mounting design for left or right hand cabling Handle can be padlocked in the OFF position with up to three padlocks with 5/16" hasps. A cover padlocking provision is also supplied DISCONNECT SWITCHES 4 3-Pole, Horizontal Mount Maximum Ampere Rating Catalog Number Maximum AC Voltage Rating Horsepower Rating Fuse Class Dimensions (inches*) 240V H W D Std Max Std 480V Max Std 600V Max 250V DC List Price $ 5117.00 HCP367HJ400 1400 600 J 16.25 17.22 7.38 150 125 100 250 125 350 40 HCP367HJ600 1600 600 J 16.25 17.22 7.38 175 200 150 400 200 400 40 5751.00 800 240 T 16.25 17.22 7.38 100 250 — — — — 50 11366.00 HCP367H 1800 600 L 16.25 17.22 7.38 100 250 200 500 250 500 50 10724.00 HCP328HT 1200 240 T 16.25 17.22 7.38 100 250 — — — — 50 12626.00 HCP368H 1200 600 L 16.25 17.22 7.38 100 250 200 500 250 500 50 10998.00 HCP367VJ400 1400 600 J 17.00 16.25 7.38 150 125 100 250 125 350 40 5117.00 HCP367VJ600▲ 1600 600 J 17.00 16.25 7.38 175 200 150 400 200 400 40 5751.00 800 240 T 17.00 16.25 7.38 100 250 — — — — 50 11366.00 HCP367V 1800 600 L 17.00 16.25 7.38 100 250 200 500 250 500 50 10724.00 HCP328VT 1200 240 T 17.00 16.25 7.38 100 250 — — — — 50 12626.00 HCP368V 1200 600 L 17.00 16.25 7.38 100 250 200 500 250 500 50 10998.00 HCP327HT 3-Pole, Vertical Mount HCP327VT Accessories T Fuse Adapter Kits (one per pole) Terminal Connectors (one lug per kit) List Price $ Catalog Number Description List Price $ (2) #1 AWG–500 kcmil (Cu or AI) 71.00 TFAK72 1800A, 300V AC 214.00 (2) #1 AWG–500 kcmil (Cu only) 120.00 TFAK75 1800A, 600V AC 238.00 TA3K500 (3) #1 AWG–500 kcmil (Cu or AI) 98.00 TFAK82 1200A, 300V AC 543.00 TC3K350 (3) #1 AWG–350 kcmil (Cu only) 151.00 Ampere Rating Catalog Number Connector Wire Range 400–600A TA2K500 400–600A TC2K500 400–800A 400–800A 800-1200A TA4H500 (4) #2 AWG–500 kcmil (Cu or AI) 182.00 800-1200A TA3H750 (3) 250–750 kcmil (Cu or AI) 278.00 Auxiliary Switch Kits Maximum Voltage Contact Ampere Rating AC DC Switch Mounting 15A 480 125 Left Pole 1NO/1NC A01HCPL4▲ 361.00 15A 480 125 Right Pole 1NO/1NC A01HCPR4 361.00 AC DC Catalog Number 120 — HCPST120 798.00 240 — 798.00 277 — HCPST240▲ HCPST277 480 — — — 4-22 List Price $ Switchboard Connection Strap Kit Shunt Trip Kit Control Voltage Contacts Catalog Number List Price $ Switch Ampere Rating Catalog Number List Price $ 400–1200A F6162D 1366.00 Compression Lug Adapter Kit The use of this kit provides for the mounting of up to four lugs per phase. Each kit accepts lugs with (2) 3/8" diameter mounting holes on 1" centers. One kit per pole line or load is required. Lugs are not provided. Ampere Rating Catalog Number List Price $ 400–1200A HCPCLP 274.00 798.00 798.00 148 HCPST480▲ HCPST48▲ 125 HCPST125▲ 798.00 798.00 *For inches / millimeters conversion, multiply inches by 25.4. ▲ Built to order. Allow 6–8 weeks for delivery. For horizontal mounting only in either 38" wide min switchboards or S5/F2 power panelboards. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Both 240 and 600V AC switches are also rated 250V DC max. Discount Schedule VBSS Disconnect Switches Type HCP Switchboard Units Dimensions 4 DISCONNECT SWITCHES Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4-23 Disconnect Switches Type TFP Fusible Pullouts Selection/Dimensions Features Type TFP Fusible Pullouts ▪ 100 and 200 Ampere Disconnects ▪ 240 Volt and 600 Volt Designs ▪ Class T Fuses ▪ Factory Installed Wire Connectors ▪ U.L. Listed for applications up to 200,000 Amps symmetrical at 600 Volts ▪ Physically interchangeable with Siemens Type QJ2, QJH2 and QJ2-H DISCONNECT SWITCHES 4 ▪ UL 1429, File No. E118778 T-Fuse Pullout TFP223 T-Fuse Pullouts 2-Pole, 2-Fuse Maximum Voltage Ampere Rating Catalog Number Connector Wire Range 햲 List Price $ 240 햳 100 200 TFP223 TFP224 (1 pc.) #6-300 kcmil Cu (1 pc.) #4-300 kcmil Al 540.00 726.00 240 햳 100 200 TFP323 TFP324 600 100 200 TFP363 TFP364 3-Pole, 3-Fuse (1 pc.) #6-300 kcmil Cu (1 pc.) #4-300 kcmil Al 652.00 873.00 807.00 1103.00 Fuses — Not included. Consult local sales office for replacement parts. Fusible Pullouts Dimensions (inches*) Class T Pullout Mounting Hardware Catalog Number MSQJ (Includes 4 screws) For inches / millimeters conversion, multiply inches by 25.4. 햲 햳 4-24 Replacement terminal lug Catalog Number TA1Q300. 240 bolt pullouts require 300 volt Class T fuses. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule HDSS 5SPEEDFAX TM 2007-2008 Enclosed Circuit Breakers Contents Enclosure Types 5-2 Complete Assemblies Molded Case Circuit Breakers Enclosed Molded Case Switches 5-3 – 5-6 5-7 Enclosures Type 1, Selection 5-8 Type 1, Dimensions 5-9 Type 3R, Selection 5-10 Type 3R, Dimensions 5-11 Types 4, 4X, 7 and 9, Selection/Dimensions 5-12 Types 5, 12 and 12K, Selection/Dimensions 5-13 Knockout and Hub Data 5-14 5 ENCLOSED CIRCUIT BREAKERS Residential Commercial Industrial Enclosed Circuit Breakers Enclosure Types General Type 3R ENCLOSED CIRCUIT BREAKERS 5 Type 1 Types 5, 12, 12K Types 7, 9 Type 1 — A general indoor, sheet-steel enclosure for use in normal atmospheres. Listed as service entrance equipment. Type 3R — An outdoor, sheet-steel enclosure providing protection against driving rain, sleet or snow. Listed as service entrance equipment. Types 7, 9 — Cast aluminum enclosure classified for explosion and fire hazard. 5-2 Only enclosure for use in hazardous location. Class I; Group D–Class II; Groups E, F, and G–Class III. Types 4, 4X (not shown) — Stainless steel indoor or outdoor enclosure designed for use in areas where serious corrosion problems exist. They provide a degree of protection against windblown dust, rain, splashing water and hosedirected water. Meets NEMA Type 3, 4, Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4X, 12 and 13 requirements and UL 508 Type 4 and 4X requirements. Types 5, 12 — A special-industry, sheetsteel enclosure for use in atmospheres containing particles of lint, dust, dirt, sawdust and other foreign matter. Type 12K — A semi-dusttight sheetsteel enclosure. Listed as service entrance equipment. Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit, enclosure and standard line and load pressure wire connectors — assembled and shipped as one unit from the Siemens modification center. For service equipment or applications Selection requiring a solid neutral, neutrals must be priced and ordered separately except as noted. To order, select the appropriate prefix from the table below and place it in front of the desired non-interchangeable trip or interchangeable trip circuit breaker catalog number. For circuit breaker selection, refer to pages 6-20 thru 6-124. Note: Lead times are determined based on availability of components. Items marked with ■ or ▲ in this section may contain components that are not normally stocked. Catalog Numbering Prefix Enclosure Type E1S Type 1 Surface E1F Type 1 Flush E3R Type 3R Example: Catalog number E1SJD63B400 consists of: (1) (1) (1) (6) E12 Type 12 E4X Type 4X Stainless Steel JD63F400 frame JD63T400 trip unit J6N1 enclosure TA2J6500 wire connectors Selection And Pricing By Enclosure Type Circuit Breaker Breaker Frame QJ2-H ED2 ED4 ED6 Type 3R Neutrals Type 12 Type 4, 4X 2 60-225 648.00 840.00 NA NA 3 60-225 1332.00 1565.00 NA NA 2 60-225 1236.00 1428.00 NA NA 3 60-225 1774.00 2007.00 NA NA 2 60-225 1481.00 1673.00 NA NA 3 60-225 2190.00 2423.00 NA NA 2 2 15-60 70-100 437.00 619.00 698.00 880.00 542.00 724.00 3129.00 3311.00 3 3 15-60 70-100 577.00 762.00 838.00 1023.00 682.00 867.00 3269.00 3454.00 2 2 2 15-60 70-100 110-125 670.00 835.00 1657.00 931.00 1096.00 2111.00 775.00 940.00 1835.00 3362.00 3527.00 4227.00 3 3 3 15-60 70-100 110-125 833.00 953.00 1865.00 1094.00 1214.00 2319.00 938.00 1058.00 2043.00 3525.00 3645.00 4435.00 2 2 15-60 70-100 762.00 922.00 1023.00 1183.00 867.00 1027.00 3454.00 3614.00 3 3 3 15-60 70-100 110-125 927.00 1122.00 2143.00 1188.00 1383.00 2597.00 1032.00 1227.00 2321.00 3619.00 3814.00 4713.00 Discount Schedule MCCB Lug Catalog Number (included) Catalog Number List Price $ TA1Q300 TA1Q300 ENCLOSED CIRCUIT BREAKERS QJH2 Ampere Rating Type 1 Surface or Flush 5 QJ2 Number of Poles List Price $ — Complete Assembly Included with enclosure TA1Q300 15-25A SA1E025 30-60A Line LN1E100 Load LD1E060 70-100 LN1E100 Catalog Number W53045 included with enclosure 110-125A TA1E6125 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5-3 Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers Selection Selection And Pricing By Enclosure Type Circuit Breaker Breaker Frame HED4 CED6 List Price $ — Complete Assembly Number of Poles Ampere Rating 2 2 2■ 15-60 70-100 110-125 1078.00 1219.00 2447.00 1339.00 1480.00 2901.00 1183.00 1324.00 2625.00 3770.00 3911.00 5017.00 3 3 3 15-60 70-100 110-125 1289.00 1376.00 2781.00 1550.00 1637.00 3235.00 1394.00 1481.00 2959.00 3981.00 4068.00 5351.00 2■ 2■ 15-100 110-125 3027.00 4406.00 3481.00 4860.00 3205.00 4584.00 NA NA 3 3■ 15-100 110-125 3471.00 5156.00 3925.00 5610.00 3649.00 5334.00 NA NA ENCLOSED CIRCUIT BREAKERS 5 Circuit Breaker Breaker Frame FXD6, FD6 HFD6 CFD6 JXD2 JXD6, JD6 HJD6 HHJD6 CJD6 Type 3R Type 12 Type 4, 4X Lug Catalog Number (included) List Price $ Catalog Number W53045 included with enclosure Refer to page 6-81 List Price $ — Complete Assembly Neutrals (not included) Type 1 Surface or Flush Number (included) Lug Catalog Catalog Number List Price $ TA1FD350A N250 햳 143.00 TA2J6500 W60992 햲 492.00 Ampere Rating 2■ 70-225 250 2081.00 3343.00 2503.00 3765.00 2307.00 3569.00 6617.00 7879.00 3 70-225 250 2599.00 3898.00 3021.00 4320.00 2825.00 4124.00 7135.00 8434.00 2■ 70-225 250 4341.00 5603.00 4763.00 6025.00 4567.00 5829.00 8877.00 10139.00 ■ 3 70-225 250 5242.00 6537.00 5660.00 6959.00 5464.00 6763.00 9774.00 11073.00 3■ 70-225 250 6663.00 7369.00 7085.00 7791.00 6889.00 7595.00 NA NA 2■ 200-400 2930.00 4065.00 3397.00 9618.00 3 200-400 3541.00 4676.00 4008.00 10229.00 2■ 200-400 3568.00 4703.00 4035.00 10256.00 3 200-400 4211.00 5346.00 4678.00 10899.00 2■ 200-400 5684.00 6819.00 6151.00 12372.00 3 200-400 6796.00 7931.00 7263.00 13484.00 Type 3R Type 12 Type 4, 4X 2■ 200-400 6781.00 7916.00 7248.00 13469.00 3■ 200-400 8099.00 9234.00 8566.00 14787.00 3■ 200-400 8805.00 9974.00 9335.00 NA CSO – Consult Sales Office for pricing Catalog Number Refer to page 6-81 Number of Poles ■ Built to order. Allow 2–3 weeks for delivery. 5-4 Neutrals Type 1 Surface or Flush 햲 Order catalog number W60993 neutral for type 4, 4X enclosure or when a 200% neutral is required. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햳 For 200% neutral order catalog number N2250 (List price $258.00) Discount Schedule MCCB Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers Selection Selection And Pricing By Enclosure Type Circuit Breaker List Price $ — Complete Assembly Neutrals Number of Poles Ampere Rating LXD6, LD6 2■ 450-600 5469.00 6638.00 5999.00 3 450-600 6740.00 7909.00 7270.00 13237.00 HLD6, HLXD6 2■ 250-600 7012.00 8181.00 7542.00 13509.00 Breaker Frame Type 1 Surface Type 3R Type 12 Type 4, 4X Catalog Number List Price $ TA2J6500 W60993 햲 436.00 TA3K500 W63623 햳 606.00 11966.00 3 250-600 8798.00 9967.00 9328.00 15295.00 HHLXD6 , HHLD6 2■ 450-600 8863.00 9802.00 9163.00 15130.00 3■ 450-600 10363.00 11532.00 10893.00 16860.00 CLD6 3■ 450-600 13683.00 14852.00 14213.00 LMXD6, LMD6 2■ 500-800 CSO CSO CSO NA 3■ 500-800 CSO CSO CSO NA HLMXD6 햴 , HLMD6 2■ 500-800 CSO CSO CSO NA 3■ 500-800 CSO CSO CSO NA MXD6, MD6 2■ 500-800 7436.00 8741.00 9422.00 NA 3■ 500-800 9245.00 10550.00 11231.00 NA HMXD6 햴 , HMD6 2■ 500-800 8707.00 10012.00 10693.00 NA 3■ 500-800 10909.00 12214.00 12895.00 NA CMD6 3■ 500-800 15431.00 16736.00 17417.00 NA 햴 Lug Catalog Number (included) NA 5 ENCLOSED CIRCUIT BREAKERS ■ Built to order. Allow 2–3 weeks for delivery. CSO – Consult Sales Office for pricing 햲 For 200% neutral in Type 1, 3R & 12 enclosures use neutral catalog number W63623. Discount Schedule MCCB 햳 For applications requiring 600MCM neutral conductors (max. 3 in & 3 out) use neutral catalog number W411239 (List price $667.00). 햴 HHLXD6, HLMXD6 and HMXD6 are only available with 3-pole breakers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5-5 Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers Selection Selection And Pricing By Enclosure Type Circuit Breaker Breaker Frame NXD6 ND6 HNXD6 ENCLOSED CIRCUIT BREAKERS 5 HND6 Number of Poles List Price $ — Complete Assembly Ampere Rating Neutrals Type 1 Surface Type 3R Type 12 Type 4, 4X 2■ 900-1200 CSO CSO CSO NA 3 900-1200 CSO CSO CSO NA 2■ 2■ 800 900-1200 CSO CSO CSO CSO CSO CSO NA NA 3 3 800 900-1200 CSO CSO CSO CSO CSO CSO NA NA 3 900-1200 CSO CSO CSO NA 2■ 2■ 800 900-1200 CSO CSO CSO CSO CSO CSO NA NA 3 3 800 900-1200 CSO CSO CSO CSO CSO CSO NA NA Lug Catalog Number (included) Catalog Number List Price $ W63623 햳 606.00 N2000 1056.00 TA3K500 for 800A 2TA4N8500 for 900-1200A 2-Pole 3TA4N8500 for 900-1200A 3-Pole CND6 3■ 900-1200 CSO CSO CSO NA PXD6 햲 3■ 1200-1600 CSO CSO NA NA TA5P600 PD6 햲 3■ 1200-1600 CSO CSO NA NA TA5P600 HPXD6 햲 3■ 1200-1600 CSO CSO NA NA TA5P600 HPD6 햲 3■ 1200-1600 CSO CSO NA NA TA5P600 CPD6 햲 3■ 1200-1600 CSO CSO NA NA TA5P600 RXD6 햲 3 1600-2000 CSO CSO NA NA TC5R600 RD6 햲 3■ 1600-2000 CSO CSO NA NA TC5R600 HRXD6 햲 3■ 1600-2000 CSO CSO NA NA TC5R600 HRD6 햲 3■ 1600-2000 CSO CSO NA NA TC5R600 Special Application Complete Enclosures with Ground Fault Protection The following assemblies are suitable for use as service entrance devices on services which require ground fault protection. Selection And Pricing By Enclosure Type Breaker Type SND6 w/ground fault■ SHND6 w/ground fault■ Ampere Rating Catalog Number List Price $ Catalog Number List Price $ Circuit Breaker Installed Terminal Connector Installed Neutral Installed Neutral Sensor Installed 1000A E1SSND69100GN 18904.00 E3RSND69100GN 20209.00 SND69100AG 3TA4N8500 W63623 N10SNDA 1200A E1SSND69120GN 18904.00 E3RSND69120GN 20209.00 SND69120AG 3TA4N8500 W63623 N12SNDA 1000A E1SSHND69100GN 20365.00 E3RSHND69100GN 21670.00 SHND69100AG 3TA4N8500 W63623 N10SNDA 1200A E1SSHND69120GN 20365.00 E3RSHND69120GN 21670.00 SHND69120AG 3TA4N8500 W63623 N12SNDA ■ Built to order. Allow 2–3 weeks for delivery. CSO – Consult Sales Office for pricing 5-6 햲 Not assembled — components shipped separately. Includes connect-all mounting assembly Catalog Number MB9301. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햳 For applications requiring 600MCM neutral conductors (max. 3 in & 3 out) use neutral catalog number W411239 (List price $667.00). Discount Schedule MCCB Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Switches Selection Selection And Pricing By Enclosure Type Molded Case Switch Breaker Frame QJ2 ED2 Number of Poles Enclosure Type — List Price $ Ampere Rating Type 4, 4X 225 648.00 840.00 NA NA 1332.00 1565.00 NA NA 2■ 100 619.00 880.00 724.00 3311.00 3 100 762.00 1023.00 867.00 3454.00 2■ 100 125 835.00 1657.00 1096.00 2111.00 940.00 1835.00 3527.00 4227.00 3 100 125 953.00 1865.00 1214.00 2319.00 1058.00 2073.00 3645.00 4435.00 2■ 100 125 847.00 NA 1183.00 NA 1027.00 NA 3614.00 NA 3 100 125 1122.00 2143.00 1383.00 2597.00 1227.00 2321.00 3814.00 4713.00 2■ 100 125 3027.00 4406.00 3481.00 4860.00 3205.00 4584.00 NA NA 3■ 100 125 3471.00 5156.00 3925.00 5610.00 3649.00 5334.00 NA NA Molded Case Switch Catalog Number TA1Q300 Included with enclosure Refer to page 6-81 Refer to page 6-81 Refer to page 6-81 Type 1 Surface Type 1 Flush Catalog Number W53045 included with enclosure Refer to page 6-81 Enclosure Type — List Price $ Ampere Rating List Price $ Neutrals (not included) Type 3R Type 12 Type 4, 4X 2 250 3343.00 3343.00 3765.00 3569.00 7879.00 3 250 3898.00 3898.00 4320.00 4124.00 8434.00 3■ 250 7369.00 7369.00 7791.00 7595.00 2■ 400 2930.00 NA 4065.00 3397.00 9618.00 3 400 3541.00 NA 4676.00 4008.00 10229.00 Lug Catalog Number (included) Catalog Number List Price $ TA1FD350A N250햴 143.00 TA2J6500 W60992 NA 햳 492.00 햳 492.00 JXD6 3 400 4211.00 NA 5346.00 4678.00 10899.00 TA2J6500 W60992 CJD6 3■ 400 8805.00 NA 9974.00 9335.00 NA TA2J6500 W60992 햳 492.00 LXD6 3 600 6740.00 NA 7909.00 7270.00 13237.00 TA2J6500 W60993 햵 436.00 CLD6 3■ 600 13683.00 NA 14852.00 14213.00 NA TA2J6500 W60993 햵 436.00 MXD6 3 800 9245.00 NA 10550.00 11231.00 NA CMD6 3■ 800 CSO NA NA TA3K500 W63623 햶 606.00 3TA4N8500 W63623 햶 606.00 CSO NA NXD6 3 1200 CSO NA NA CSO NA CND6 3■ 1200 CSO NA NA CSO NA 햲 3■ 1600 CSO NA NA NA NA TA5P500 N2000 1056.00 RXD6 햲 3■ 2000 CSO NA NA NA NA TC5R600 N2000 1056.00 PXD6 ■ Built to order. Allow 2–3 weeks for delivery. CSO – Consult Sales Office for pricing 햲 Not assembled — components shipped separately. Includes connect-all mounting assembly Catalog Number MB9301. Discount Schedule MCCB 햳 Order Catalog Number W60993 neutral for Type 4, 4X enclosure or when a 200% neutral is required. 200% neutral order catalog number N2250 (List price $258.00) 햵 For 200% neutral in Type 1, 3R & 12 enclosures use neutral catalog number W63623. 햴 For 햶 For applications requiring 600 MCM neutral conductors (Max. 3 in and 3 out) use neutral catalog number W411239 (List price $667.00). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5-7 ENCLOSED CIRCUIT BREAKERS Number of Poles Lug Catalog Number (included) 5 JXD2 Type 12 225 CED6 CFD6 Type 3R 3 ED6 FXD6 Neutrals 2■ ED4 Breaker Frame Type 1 Surface or Flush Enclosed Circuit Breakers Enclosures — Type 1 Selection Dimensions Figure 1 Figure 3 Figure 2 Type 1 Number Maximum of Current Catalog Poles Rating Number Fig. Breaker No. Frame K.O. Dimensions Weight Lb./Ship. Package Dimensions (inches) 6 Plcs. 2 Plcs. A B C D E F G H 016 071⁄8 051⁄8 033⁄8 053⁄4 033⁄4 11⁄16 — — 8 171⁄8 0 1 7 ⁄8 0 1 4 ⁄4 141⁄8 0 1 4 ⁄2 15⁄16 — — 0 32 171⁄8 0 1 7 ⁄8 0 3 4 ⁄4 141⁄8 0 1 4 ⁄2 15⁄16 — — 7 ⁄8, 11⁄8, 13⁄8, 7 ⁄8, 11⁄8, 13⁄8, 1 QP, QPH, HQP 1–2 0060 E0204ML1060S 1 QP, QPH, HQP 3 0 100 E0303ML3100S 189.00 1 BQ, BQH, HBQ 3 0 100 EB3100S 189.00 NGG 2-3 125 GG0121FN/SN 139.00 2 ED2, ED4, ED6, HED4 2–3 0 100 E2N1S E2N1F 149.00 149.00 008 008 1623⁄32 171⁄2 071⁄2 081⁄2 051⁄16 051⁄16 1345⁄64 1345⁄64 051⁄4 051⁄4 1 1 2 ED4, ED6, HED4, CED6 2–3 0 125 CED6N1S CED6N1F 271.00 271.00 014 014 2115⁄32 221⁄4 0719⁄32 081⁄2 057⁄64 057⁄64 181⁄4 181⁄4 051⁄4 051⁄4 1 1 13⁄4, 2 13⁄4, 2 2 FXD6, FD6, FXD6, FD6, HFD6, HFXD6, HHFD6, CFD6 2–3 0250 F6N1S F6N1F 184.00 184.00 033 3813⁄32 1115⁄32 051⁄16 33 08 133⁄64 11⁄8, 13⁄8, 13⁄4, 2, 21⁄2, 3 11⁄8, 13⁄8, 13⁄4, 20, 21⁄2, 3 3 JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 2–3 0400 J6N1 258.00 120 413⁄16 2227⁄64 1045⁄64 37 181⁄4 25⁄64 — — LD6, LXD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6, SCJD6, SCLD6, CJD6, CLD6 2–3 0600 LD6N1 449.00 101 46 2227⁄64 1045⁄64 42 181⁄4 25⁄64 — — 2–3 0 800 LMD1 897.00 202 60 2227⁄64 10 557⁄8 181⁄4 25⁄64 — — 3 MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, ND6, NXD6, 2–3 SND6, HND6, HNXD6, SHND6, CMD6, SCMD6, CND6, SCND6 1200 MND61 897.00 202 60 2227⁄64 10 557⁄8 181⁄4 25⁄64 — — — PD6, PXD6, HPD6, HPXD6, CPD6, RD6, SPD6, SHPD6, RXD6, HRD6, HRXD6 2000 PRD6N1 ■ 6324.00 350 90 32 28 — — — — — 5 ENCLOSED CIRCUIT BREAKERS List Price $ 3 3 LMXD6, LMD6, HLMXD6, HLMD6 76.00 00 3 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. CSO – Consult Sales Office for pricing Surface mounted, indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. Also, if outdoor model required, use prefix “W” instead of “E”. 5-8 Discount Schedule B. not include circuit breaker. Order circuit breaker separately. Neutral not included. Order as separate item from table on next page. Neutral included in enclosure. Surface mounted, indoor. If outdoor model is required, use prefix “W” instead of “E”. Not available in flush (“F”) model. Does Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Use for 110-125 ampere ED4, ED6, or HED4 circuit breakers. Will not accept breaker with shunt trip. Will not accept 2-pole GFP or breaker with shunt trip. Includes 100% rated breakers. Enclosure will accept shunt trip and other internal accessories except GFP. Discount Schedule MCCB Enclosed Circuit Breakers Enclosures — Type 1 Selection Dimensions Figure 4 Figure Number Breaker Frame 4 QJ2, QJH2, QH2-H Number of Poles 2–3 Maximum Current Rating 225 Catalog Number List Price $ 햴 EB3225S EB3225F 226.00햳 햶 226.00햳 햶 Weight Lb./Ship. Dimensions (inches) Package A B C D E 15 27 27 101⁄8 27 101⁄8 51⁄4 101⁄8 281⁄8 111⁄4 51⁄4 F G 213⁄16 213⁄8 213⁄16 213⁄8 H J K L 23⁄8 23⁄8 3 3 20 20 51⁄16 23⁄4 51⁄16 23⁄4 M N P 23⁄4 23⁄4 41⁄2 41⁄2 W53045 햶 Enclosure Catalog Number E2N1(S)(F) CED6N1(S)(F) 햸 N250 F6N1(S)(F) W60992 J6N1 W60993 LD6N1 W63623 N2000 LMD1 MND61 PRD6N1 Neutral Cable Capacity and Wire Range List Price $ (1 pc.) #14–2 Cu/Al Grd. Lug (1 pc.) #14–8 Cu/Al 186.00 (1 pc.) #6–350 kcmil Cu/Al Grd. Lug (1 pc.) #14–2/0 Cu/Al (1 pc.) #1/0–750 kcmil Cu/Al or (2 pcs.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al 143.00 492.00 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al 436.00 (4 pcs.) 250 kcmil–500 kcmil Cu/Al 햿 Grd. Lug (1 pc.) #6–300 kcmil Cu/Al 606.00 (6 pcs.) #3/0–750 kcmil Cu/Al Grd. Lug (2 pcs.) #3/0–750 Cu/Al ENCLOSED CIRCUIT BREAKERS Neutral Catalog Number 5 Neutrals 1056.00 200% Neutrals (For Type 1, 3R, 4/4X and 12 Enclosures) Neutral Catalog Number Enclosure Catalog Number N2250 Neutral Cable Capacity and Wire Range List Price $ F6N1(S)(F) 햻 (2 pcs.) #4–350 kcmil Cu/Al Grd. Lug (1 pc.) #14–2/0 Cu/Al 258.00 W60993 J6N1 햽 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6-250 kcmil Cu/Al 436.00 W63623 LD6N1 햾 (4 pcs.) 250 kcmil–500 kcmil Cu/Al Grd. Lug (1 pc.) #6–300 kcmil Cu/Al 606.00 For inches / millimeters conversion, see Application Data section. CSO – Consult Sales Office for pricing 햲 Surface mounted, indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. Also, if outdoor model required, use prefix “W” instead of “E”. 햳 Discount Schedule B. 햴 Does not include circuit breaker. Order circuit breaker separately. 햵 Neutral not included. Order as separate item from table on next page. Discount Schedule MCCB 햶 Neutral included in enclosure. mounted, indoor. If outdoor model is required, use prefix “W” instead of “E”. Not available in flush (“F”) model. 햸 Use for 110-125 ampere ED4, ED6, or HED4 circuit breakers. 햹 Will not accept breaker with shunt trip. 햻 Also for use with Type 3R, 12, 12K & 4X enclosures (Catalog numbers F6N3R, F6N12, F6N12K & FD6SS4). 햷 Surface 햽 Also for use with Type 3R, 12 & 4X enclosures (Catalog numbers J6N3R, J6N12, & LD6SS4). for use with Types 3R and 12 enclosures (Catalog numbers LD6N3R & LD6N12). 햿 For 600 MCM neutral cable (3) in, (3) out (#4–600 kcmil Cu/Al) use catalog number W411239 (List price $667.00) 햾 Also Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5-9 Enclosed Circuit Breakers Enclosures — Type 3R Selection Figure 2 Figure 1 Figure 3 Type 3R Number Maximum of Current Catalog Poles Rating Number Figure Breaker Number Frame 햷 A B C D E F G H 081⁄8 051⁄8 043⁄8 — — — — — 396.00햲 024 231⁄8 101⁄2 045⁄16 20 071⁄2 115⁄16 051⁄4 — 17 ⁄8 0 3 7 ⁄8 0 5 4 ⁄16 — 171⁄8 0 3 7 ⁄8 0 12 179⁄16 725.00 016 1–2 0060 W0204ML1060 2 QPP, QPPH, HQPP 1–4 0225 W0406ML1225CU 햶 2 QP, QPH, HQP 3 0 100 W0303ML3100 2 BQ, BQH, HBQ 3 3 0050 100 WB3100 햶 249.00햲 NGG 2-3 125 GG0123RN 377.00 ED2, ED4, ED6, HED4, HED6 2–3 0 100 E2N3R 햵 410.00 5 햵 Dimensions (inches) 028 햲 QP, QPH 햶 Weight Lb./Ship. Package 141.00 2 5 ENCLOSED CIRCUIT BREAKERS List Price $ 햳 햲 249.00 00 9 00 9 14 ⁄8 0 1 4 ⁄2 1 ⁄8 0 11 3 ⁄16 0 5 4 ⁄16 141⁄8 0 1 4 ⁄2 11⁄8 0 11 3 ⁄16 — 0 1 7 ⁄4 0 1 5 ⁄4 1239⁄64 0 1 5 ⁄4 1 0 3 — 22 ⁄64 07 ⁄4 05 ⁄4 17 ⁄8 05 ⁄4 1 03 — 1 1 1 5 CED6 2–3 0125 CED6N3R 1 FXD6, FD6, FXD6, FD6, HFD6, HFXD6, HHFD6, CFD6 2–3 0250 F6N3R 햴 606.00 045 381⁄8 141⁄16 073⁄4 339⁄32 08 513⁄16 131⁄2 513⁄16 햸 1 JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 2–3 0400 J6N3R 햴 1393.00 126 4063⁄64 263⁄4 1123⁄32 353⁄4 181⁄4 21⁄8 241⁄2 11⁄8 햸 1 LD6, LXD6, LXD6H, HLD6, HLXD6, HHLD6, HHLXD6, CJD6, CLD6, SCJD6, SLD6, SHLD6 2–3 0 600 LD6N3R 햴 1618.00 137 4563⁄64 263⁄4 1123⁄32 403⁄4 181⁄4 21⁄8 241⁄2 11⁄8 4 LMXD6, LMD6, HLMXD6, HLMD6 2–3 0 800 LMD3R 햴 2202.00 210 619⁄64 263⁄4 1123⁄32 5717⁄32 181⁄4 21⁄8 245⁄8 11⁄16 2–3 1200 MND63 햴 2202.00 210 619⁄64 263⁄4 1123⁄32 5717⁄32 181⁄4 21⁄8 245⁄8 11⁄16 MD6, MXD6, SMD6, 햸 HMD6, HMXD6, SHMD6, ND6, NXD6, SND6, HND6, HNXD6, SHND6, CMD6, SCMD6, CND6,SCND6 1 For inches / millimeters conversion, see Application Data section. 햲 Discount Schedule B. 햳 Does not include circuit breaker. Order circuit breaker separately. 5-10 21 1 1 3 1 햴 Neutral not included. Order as separate item from table on next page. included in enclosure. 햶 Will not accept breaker with shunt trip. 햷 Will not accept 2 pole GFP or breaker with shunt trip. 햸 Includes 100% rated breakers. 햵 Neutral Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Enclosed Circuit Breakers Enclosures — Type 3R Selection / Dimension Dimensions Figure 4 Number Maximum of Current Poles Rating QJ2, QJH2, 2 QJ2-H 3 6 225 225 Catalog Number List Price $ Weight Lb./Ship. Package Dimensions (inches) A B C D E F G H J K L M WB2225 WB3225 418.00 459.00 17 17 27 27 5 55⁄8 0711⁄16 103⁄8 21⁄4 21⁄4 2 2 27⁄8 27⁄8 20 20 41⁄8 41⁄8 35⁄8 51⁄8 23⁄4 23⁄4 23⁄4 23⁄4 — 41⁄2 ENCLOSED CIRCUIT BREAKERS Neutrals Neutral Catalog Number W53045 N250 W60992 W60993 W63623 Enclosure Catalog Number Neutral Cable Capacity and Wire Range List Price $ (1 pc.) #14–2 Cu/Al Grd. Lug (1 pc.) #14–8 Cu/Al 186.00 F6N3R (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al 143.00 J6N3R (1 pc.) #1/0–750 kcmil Cu/Al or (2 pcs.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al 492.00 LD6N3R (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al 436.00 E2N3R CED6N3R LMD3R MND63 (4 pcs.) 250 kcmil–500 kcmil Cu/Al Grd. Lug (1 pc.) #6–300 kcmil Cu/Al 606.00 Hubs — see page 5-14. For inches / millimeters conversion, see Application Data section. Discount Schedule B. Does not include circuit breaker. Order circuit breaker separately. Discount Schedule MCCB Neutral not included. Order as separate item from table on next page. Neutral included in enclosure. Use CED enclosure for all ED-frame 110-125 ampere units. 200% neutrals are also available. See listing on page 5-9. 5 Figure Breaker Number Frame Figure 5 For applications requiring 600MCM neutral conductors (3) in, (3) out (#4-600 kcmil Cu/Al) use neutral catalog number W411239 (List price $667.00). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5-11 Enclosed Circuit Breakers Enclosures — Types 4, 4X, 7, and 9 Selection / Dimensions Dimensions Figure 1 Figure 2 Figure 1 Types 4 and 4X Number of Poles ENCLOSED CIRCUIT BREAKERS 5 Breaker Frame Maximum Current Rating Catalog Number Weight Lb./Ship. Package List Price $ 햲 ED2, ED4, ED6, HED4 3 125 ED6SS4 FXD6, FD6, HFD6, FXD6, FD6 2–3 250 FD6SS4 2–3 600 LD6SS4■ 햸 햸 Dimensions (inches) A B C D E 5 F 3 2841.00 044 20 16 06 07 ⁄32 09 ⁄4 3 4720.00 106 36 24 08 095⁄32 113⁄4 3 6946.00 145 42 30 10 115⁄32 133⁄4 3 햹 JXD2, JXD6, JD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6, LXD6, LD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6 햸 Neutrals Neutral Catalog Number W53045 N250 Enclosure Catalog Number햳 햴 햵햷 W60993 햵햷 Neutral Cable Capacity and Wire Range List Price $ ED6SS4 (1 pc.) #14–2 Cu/Al Grd. Lug (1 pc.) #14–8 Cu/Al 186.00 FD6SS4 (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al 143.00 LD6SS4 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al 436.00 Figure 2 Types 7 and 9 햶 Number of Poles Breaker Frame ED2, ED4, ED6, HED4 2–3 Maximum Current Catalog List Rating Number 햵 햷 Price $ 햲 015–60 070–100 EA■ EB■ Weight Lb./Ship. Package Dimensions (inches) Mounting Inside A C 1750.00 027 2176.00 032 0 1 5 ⁄2 0 6 B Knockouts Outside D E 13 ⁄8 18 0 15 5 ⁄16 103⁄4 0 1 6 ⁄2 16 1 F 5 ⁄16 59⁄16 0 7 9 ⁄16 0 7 9 ⁄8 7 Conduit Size G H 1 K Std. 1 Max 14 ⁄4 193⁄8 5 6 ⁄8 611⁄16 5 1 ⁄8 2 1 ⁄4 2 11⁄4 2 CED6 2–3 100 N/A FXD6, FD6, HFD6, HFXD6, CFD6 2–3 250 EC2 ■ 4815.00 085 101⁄4 225⁄8 113⁄4 20 61⁄2 153⁄8 237⁄8 81⁄4 23⁄4 21⁄2 2 JXD2, JXD6, JD6, SJD6, 2–3 HJD6, HJXD6, HHJD6, HHJXD6, SHJD6 200–350 300–400 EC4 ■ EE ■ 4815.00 85 0 6662.00 93 0 101⁄4 081⁄2 225⁄8 271⁄8 113⁄4 103⁄4 20 241⁄8 61⁄2 73⁄4 153⁄8 137⁄8 237⁄8 271⁄4 81⁄4 99⁄16 23⁄4 4 21⁄2 3 3 4 LXD6, LD6, SLD6, HLD6, HLXD6, HHLD6, HHLXD6, SHLD6 600 ED6 ■ 11330.00 190 117⁄8 403⁄4 133⁄8 377⁄8 77⁄8 181⁄8 425⁄8 97⁄8 35⁄8 4 4 2–3 For inches / millimeters conversion, see Application Data selection. ■ Built to order. Allow 2–3 weeks for delivery. 햲 Does not include circuit breaker. Order circuit breaker separately. 5-12 햳 Enclosures shipped with handle and breaker hardware packaged within enclosure. 햴 Neutral included. 햵 Neutral not included. Order as separate item. 햶 Breather and drain option is by SPECIAL ORDER only — add $70.00 to list price. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햷 For 400A max. 4/4x applications which require a 200% Neutral. See listing on page 5-9. for use as Service Entrance device. 햹 Includes 100% rated breakers. 햸 Suitable Discount Schedule MCCB Enclosed Circuit Breakers Enclosures — Types 5, 12 and 12K Selection / Dimensions Types 5, 12 and 12K Figure Number 2 Number of Poles Breaker Frame Maximum Current Rating NGG 2–3 125 ED2, ED4, ED6, HED4 2–3 0100 Catalog Number List Price $ 햳 GG01212N 233.00 E2N12 햲 햵 254.00 햲햵 ■ Weight Lb./Ship . Package Dimensions (inches) A B C D E F 012 185⁄8 0811⁄32 071⁄16 18 061⁄16 1 1 5 ⁄2 1 CED6 2–3 0125 CED6N12 449.00 016 22 ⁄8 08 ⁄32 07 ⁄16 22 06 ⁄16 2 FXD6, FD6, FXD6, FD6, HFD6, CFD6 2–3 0250 F6N12 햲 햴 410.00 040 3819⁄32 1429⁄64 081⁄8 34 13 23 3 JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 2–3 0400 J6N12 725.00 104 411⁄2 215⁄8 117⁄8 375⁄32 203⁄8 5 3 LD6, LXD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6, CJD6, CLD6, SCJD6, SCLD6 2–3 0600 LD6N12 ■ 979.00 104 461⁄2 215⁄8 117⁄8 425⁄32 203⁄8 5 4 LMXD6, LMD6, HLMXD6, HLMD6 2–3 0800 LMD12 ■ 2883.00 220 — — — — 4 햹 MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, ND6, NXD6, SND6, HND6, HNXD6, SHND6, CMD6, SCMD6, CND6, SCND6 2–3 1200 MND612 햴 ■ 2883.00 220 60 373⁄8 10 005⁄8 5 11 1 ⁄8 ⁄32 ⁄8 ⁄8 — — 3 2 5 Dimensions ENCLOSED CIRCUIT BREAKERS Figure 2 Figure 3 Figure 1 Neutrals Neutral Catalog Number W53045 햵 Enclosure Catalog Number E2N12 CED6N12 햶 Neutral Cable Capacity and Wire Range List Price $ (1 pc.) #14–2 Cu/Al (1 pc.) #14–2 Cu/Al 186.00 143.00 N250 햴 햷 F6N12 (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al W60992 햴 햷 J6N12 (1 pc.) #1/0–750 kcmil Cu/Al or (2 pc.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al L6N12 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al 436.00 (4 pcs.) 250 kcmil–500 kcmil Cu/Al Grd. Lug (1 pc.) #6–300 kcmil Cu/Al 606.00 W60993 햴 햷 W63623 햴 LMD612 MND612 For inches/millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. CSO – Consult Sales Office for pricing. 햲 Catalog Number is for Type 12. If Type 12K with knockouts is required, add suffix “K” to catalog number. Discount Schedule MCCB 햳 Does not include circuit breaker. Order circuit breaker separately. 햴 Neutral not included. Order as separate item. 햵 Neutral included in enclosure. 햶 Use CED enclosure for all ED-frame 110–125 ampere units. 492.00 Figure 4 햷 200% neutrals are also available. See listing on page 5-9. 600 MCM neutral cable (3) in, (3) out (#4-600 kcmil Cu/Al) use catalog number W411239 (List price $667.00) 햹 Includes 100% rated breakers. 햸 For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5-13 Enclosed Circuit Breakers Enclosures — Knockout and Hub Data Dimensions Knockouts & Wire Bending Space Types 1, 12 and 12K Type 3R Number of Knockouts Per Panel (Type 4, 4X, 12 have no KO’s) Breaker Frame Conduit Range Per Knockout Outside Dimensions (inches) Top Bottom Side Back Bottom Side ⁄2, ⁄4, 1, 1 ⁄4, 1 ⁄2 4 4 4 4 3 1 1 2 71⁄8" high encl. #6 햴 ⁄4, 1, 11⁄4 1 1 2 2 8 1 3 2 햵 1 BQ, BQH, HBP 70–100 3 QPP, QPPH, HQPP 125–225 1 ⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2 — — — — 4 1 1 21⁄2 250 kcmil QJ 11⁄2, 2, 21⁄2, 3 2 2 2 2 3 1 1 21⁄2 햵 NGG 3 ⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2 — — — — — — — — ED2, ED4, ED6, HED4 7 ⁄8, 11⁄8, 13⁄8, 13⁄4, 2 2 2 2 2 2 1 1 2 햵 ⁄8, 11⁄8, 13⁄8, 13⁄4, 2 2햲 2햲 — — 2 — — 2 2 2햳 2햳 — 1 1 2 햵 ⁄8, 11⁄8, 13⁄8, 13⁄4, 2, 21⁄2 햳 햳 4 햵 3 1 1 7 5 Maximum Cable Sizes Recommended (Cu/Al) for Type 1, 3R, 4, 4X, 12 & 12K Enclosures 햶 햷 QP, QPH, HQP 15–125 CED6 ENCLOSED CIRCUIT BREAKERS Back Maximum Hub Size (inches) Type 3R 7 1 1 2 1 1 — 1 1 — — 1 — — 11⁄2, 2, 21⁄2, 3, 31⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmil LXD6, LD6, HLXD6, HLD6, HHLD6, HHLXD6, SLD6, SHLD6 11⁄2, 2, 21⁄2, 3, 31⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmil LMXD6, LMD6 HLMXD6, HMLD6 — — — — — — — — 4 (3) 600 kcmil MD6, SMD6, HMD6 ND6, SND6, HND6 — — — — — — — — 4 (3) 600 kcmil or (4) 500 kcmil FXD6, FD6, FXD6, FD6 HFD6, CFD6 11⁄8, 13⁄8, 13⁄4, 2, 21⁄2, 3 JXD2, JXD6, JD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 2 (CFD6 only 300 kcmil) Hubs (Type 3R) Conduit Size (inches) Catalog Number List Price $ 03⁄4 1 11⁄4 11⁄2 2 ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 39.50 39.50 39.50 39.50 69.00 QPP, QPPH, HQPP, QJ2, QJH2, QJ2-H 11⁄4 11⁄2 2 21⁄2 ECHS125 ECHS150 ECHS200 ECHS250 39.50 39.50 69.00 109.00 ED2, ED4, ED6, HED4, HED6, HHED6, CED6 03⁄4 1 11⁄4 11⁄2 2 ECHR075 ECHR100 ECHR125 ECHR150 ECHR200 40.00 39.50 39.50 40.00 70.00 FXD6, FD6, HFD6, HFXD6, CFD6, JXD2, JD6, JXD6, HJD6, HJXD6, LD6, LXD6, HLD6, HLXD6(A) 21⁄2 3 31⁄2 4 ECHV250 ECHV300 ECHV350 ECHV400 125.00 182.00 274.00 362.00 Breaker Frame QP, QPH, HQP, BQ, BQH, HBQ, NGG For inches / millimeters conversion, see Application Data section. 햲 Type 12K only. 햳 Type 12K enclosure has no knockouts this location. 5-14 햴 171⁄8" high enclosure provides sufficient wire bending space for all available CB lugs. 햵 Sufficient wire bending space is provided for all available mechanical type CB lugs. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Note: Enclosures for 250A max breakers have a hub provision on the rainshed. Enclosures for larger breakers (J, L, M & N frame) have blank top rainsheds. Drill or punch hole in the field to accommodate hub size desired. 햶 The use of cables larger than those listed below may violate NEC & UL wire bending space requirements. use of compression type connectors will violate NEC and UL wire bending space requirements. 햷 The Discount Schedule MCCB 6SPEEDFAX TM 2007-2008 Molded Case Circuit Breakers Contents 6-34 – 6-36 6-37 – 6-39 6-40 – 6-43 6-44 – 6-47 6-48 – 6-50 6-51 – 6-54 6-55 – 6-58 6-59 – 6-61 6-62 – 6-63 6-64 – 6-65 6-66 – 6-68 6-69 – 6-71 6-72 6-73 – 6-74 6-75 – 6-78 6-79 – 6-80 6-81 – 6-83 6-84 6-85 6-86 – 6-91 6-92 – 6-95 6-96 – 6-99 6-100 – 6-103 6-104 – 6-107 6-108 – 6-111 6-112 – 6-115 6-116 – 6-119 6-120 – 6-122 6-123 6-124 6-125 – 6-139 6-140 6-141 6-142 – 6-143 6-144 – 6-145 6-146 – 6-150 6-151 – 6-152 6-153 6-154 6-155 – 6-157 MOLDED CASE CIRCUIT BREAKERS Residential Commercial Industrial 6-2 – 6-3 6-4 6-5 – 6-7 6-8 – 6-17 6-18 – 6-19 6-20 6-21 6-22 – 6-23 6-24 – 6-25 6-26 6-27 6-28 6-29 6-30 6-31 6-32 – 6-33 6 What’s New in Circuit Breakers Federal Specifications Classification Catalog Numbering System Reference Guides Panelboard Mounting 240V Circuit Breakers Special Application Panelboard Mounting 240V Circuit Breakers BQD 100A Frame 480/277V Circuit Breakers NGB 125A Frame Panelboard 480/277V Breaker and Internal Accessories EB 125A Frame Panelboard Mounting 480V Breaker and Internal Accessories Lug-In/Lug-Out 240V Breakers w/INSTA-WIRE BQXD DIN Rail Mounted 240V Circuit Breakers QJ 225A Frame CQD 100A Frame NGG 125A Frame Internal Accessories for CQD100A and NGG 125A Circuit Breakers EG 125A Frame Circuit Breakers and Internal Accessories Sentron Thermal Mag and Electronic Circuit Breakers ED 125A Frame and Internal Accessories FD 250A Frame and Internal Accessories JD/SJD 400A Frame and Internal Accessories LD/SLD 600A Frame and Internal Accessories LMD 800A Frame and Internal Accessories MD/SMD 800A Frame and Internal Accessories ND/SND 1200A Frame and Internal Accessories PD/SPD 1600A Frame and Internal Accessories RD 2000A Frame and Internal Accessories STD 3200A Frame and Internal Accessories Magnetic Trip Only—ETI Motor Circuit Protector Adjustable Instantaneous Magnetic Trip Settings Molded Case Switch—Circuit Disconnect Sensitrip III Digital Solid State Sentron Series WL Power Circuit Breakers—Insulated Case Circuit Breakers Electronic and Communications Accessories Lug Information Breaker Modifications Internal Accessories—Feature Combinations External Accessories VL Thermal Mag and Electronic Circuit Breakers Overview DG 150A Frame and Internal Accessories FG 250A Frame and Internal Accessories JG 400A Frame and Internal Accessories LG 600A Frame and Internal Accessories MG 800A Frame and Internal Accessories NG 1200A Frame and Internal Accessories PG 1600A Frame and Internal Accessories Molded Case Switch Molded Case Protector External Accessories Accessory Locations Suffix for Internal Accessories Technical Data Unusual Operating Conditions General Technical Series Short Circuit Ratings Unusual Operating Conditions IEC 947—2 AC Interrupting Ratings Typical Specifications Superseded Circuit Breakers Molded Case Circuit Breakers Introduction Molded Case Circuit Breakers OEM Circuit Breakers In this issue of the Speedfax, Siemens introduces the modular and flexible design of Siemens VL molded case circuit breakers (MCCB) for OEM applications. This family of MCCB’s allow the OEM customer the flexibility of last minute changes, with a minimum level of stock due to product modularity. The VL family of MCCB’s also offer the widest range of field installable accessories in the industry. Ratings Voltage Standards 30-1600A 600Vac 690Vac (IEC) UL, CSA, NOM, IEC, CE Marked Interruption Ratings (UL/CSA) N H L 35kA @ 480Vac 65kA @ 480Vac 100kA @ 480Vac Panelboard Application Circuit Breakers MOLDED CASE CIRCUIT BREAKERS 6 Two new MCCB offerings for Panelboard applications are introduced in this issue. NGB—The new NGB is a quick bolt-in panelboard molded case circuit breaker based on the compact design of the highly successful Siemens NGG (cable-in / cable-out) MCCB. Ratings 15-125A Poles 1, 2, 3 Voltage 480Y/277 AIC 25kA @ 480Vac Standards UL, CSA, NOM EB—The new EB circuit breaker is also a compact quick bolt-in design for panelboard application only. Ratings Poles Voltage AIC Standards 15-125A 1, 2, 3 600Y/347 35-65kA @ 480Vac UL, CSA, NOM, CE Marked Sentron Molded Case Circuit Breakers Note: The SENTRON family continues to be the standard offering of MCCB’s for all applications, with the exception of 800A-1600A for Siemens panelboard and switchboards. These products will incorporate the new VL series of circuit breakers. 6-2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Molded Case Circuit Breakers Introduction Ordering 500V DC Wiring Configuration Connecting Breakers for DC Application Most Siemens thermal magnetic trip MCCBs are applicable on direct current (dc) systems. Generally, for 250 V dc systems a two pole breaker is used, with one pole on each leg of the supply circuit. For three pole breakers applied on 500 V undergrounded DC systems, it is important to connect the power supply “zig-zag” through the breaker as shown in the figure below. This assures that the Voltage between phases on the breaker terminals is uniformly distributed. MOLDED CASE CIRCUIT BREAKERS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6 In the FD through RD frames, you may order molded case circuit breakers three basic ways: ▪ As separately ordered frames, trip units and lugs ▪ As frame, trip unit and lugs ordered as one catalog number and shipped unassembled or assembled ▪ As Frame and Trip Unit shipped assembled and with the trip unit made non-removable, in compliance with UL 489 requirements that to be reverse fed the circuit breaker must not have an interchangeable trip unit. These two options are described in the following: Components Ordered Separately To get the components for a 3-pole, 400 Amp standard interrupting circuit breaker, you would order the frame (JD63F400), the trip unit (JD63T400) and six lugs (TA2J6500). This option is normally useful only if you stock and use large volumes of product and wish to reduce your inventory cost. You may stock, for example, a smaller number of frames (JD63F400) and a variety of trip units (JD63T300, JD63T350, etc.) and assemble breakers as you need them. Frame, Trip Unit and Lugs Ordered Together If you order the catalog number JD63B400, you will receive a frame, a trip unit and 6 lugs in separate packages. By suffixing this number with “L” (e.g. JD63B400L), you will receive frame, trip unit and lugs assembled in one container. Pursuant to UL 489, a product ordered thus will have the markings “LINE” and “LOAD”, and may not be “reverse fed” (with power flowing from the “OFF” end of the breaker toward the “ON” end). Non-Interchangeable Trip Breakers If you place an “X” after the frame size designator (e.g. JXD63B400), you will receive a frame and trip unit assembled, with the trip unit made non-removable. If you suffix an “L” to this catalog number (e.g. JXD63B400L), you will receive the breaker, non-removable trip unit and lugs assembled. Unless you anticipate a specific need to change the breaker's ampere rating in the future, this is the preferred ordering method, as the products are assembled to Siemens' specifications in our factories. These breakers are suitable for use reverse fed according to UL 489, since the trip unit is not removable. The smaller frames (QJ, ED and below) do not have removable trip units, and consequently are shipped only as assembled products. To add lugs, see the ordering instructions on each product's catalog page. 6-3 Molded Case Circuit Breakers Federal Specification Classification Reference W-C-375C/GEN Interrupting Rating Class Symmetrical Amperes 햲 햴 Volts AC 60HZ Poles 10a햳 5,000 120/240 1 or 2 15–100 10b 5,000 240 2 or 3 15–100 QP, BQ, BQD, CQD, BL 11a 7,500 120 1 15–100 QP, BQ, BQD, CQD, BL 11b 7,500 12a햳 10,000 Range of Current Trip QP, BQ, QT, BL 240 2 or 3 15–100 QP, BQ, BQD, CQD, BL 120/240 1 or 2 15–100 QP, BQ, QT, ED2, BL 12b 10,000 240 2 or 3 15–225 QP, BQ, QJ2, ED2, BQD, CQD, BL 12c 10,000 277 1 15–100 BQD, CQD, NGG, NGB, NEG, NEB 13a 14,000 277 1 15–100 ED4, BQD, CQD, NGG, NGB, NEG, NEB 13b 14,000 277/480 1, 2, or 3 15–100 ED4, BQD, CQD 14a 22,000 120/240 1 or 2 15–100 QPH, BQH, BLH 14b 22,000 240 2 or 3 70–400 QJH2, QJ2-H, BQH, BQD, CQD, BLH 15a 65,000 120/240 1 or 2 15–100 HQP, HBQ, ED4, HED4, NGG, NGB, NEG, NEB 15b 65,000 240 2 or 3 15–225 ED6, ED4, FXD6, FD6, HED4, BQD, CQD, HQJ2H, NGG, NGB, NEG, NEB 16a 100,000 480 2 or 3 15–225 CFD6, CED6 16b 100,000 600 2 or 3 15–600 CED6, CFD6, CJD6, SCJD6, CLD6, SCLD6 17a 200,000 600 2 or 3 70–2000 — 18a 18,000 14,000 14,000 240 480 600 2 or 3 15–125 ED6, HED6, HHED6 19a 22,000 18,000 14,000 240 480 600 2 or 3 70–225 FXD6, FD6, CFD6, HFD6 20a 25,000 22,000 22,000 240 480 600 2 or 3 70–225 FXD6-A, FD6-A, CFD6, HFD6 21a 42,000 30,000 22,000 240 480 600 2 or 3 70–800 HFD6, CFD6, JXD6(A), JD6(A), SJD6(A), HJD(A), HJXD6(A), HHJD6, SHJD6(A), CJD6, SCJD6, LXD6(A), LD6(A), SLD6(A), HLD6(A), HLXD6(A), HHLD6, SLD6(A), SHLD6(A), CLD6, SCLD6, LMD6, LMXD6, HLMD6, HLMXD6, MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, CMD6, SCMD6 22a 65,000 25,000 18,000 240 480 600 2 or 3 15–125 CED6, ED6, HED6, HHED6, FXD6-A, FD6-A HHED6, FXD6-A, FD6-A, HFD6, HHFD6, CFD6, JD6(A), JXD6(A), SJD6(A), HJD6(A), HJXD6(A), SHJD6(A), HHJD6, HHJXD6, CJD6, SCJD6, LXD6(A), LD6(A), SLD6(A), HLD6(A), HLXD6(A), SHLD6(A), HHLD6, HHLXD6, CLD6, SCLD6, LMD6, LMXD6, HLMD6, HLMXD6, MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, CMD6, SCMD6, ND6, NXD6, SND6, HND6, HNXD6, SHND6, CND6, SCND6 6 MOLDED CASE CIRCUIT BREAKERS Breaker Type (All Circuit Breakers Meet or Exceed the Indicated Class Level) 23a 65,000 35,000 25,000 240 480 600 2 or 3 70–1200 24a 65,000 50,000 42,000 240 480 600 2 or 3 1200–2000 25a 125,000 80,000 60,000 240 480 600 2 or 3 600–4000 Applicable Standards UL489 — Molded Case Circuit Breakers and Circuit Breaker Enclosures. UL486A — Wire Connectors and Solderless Lugs for use with copper wire Note: (A) Molded case circuit breakers are designed and tested in accordance to applicable portions of UL489 and meet application requirements of the National Electric Code. Unless marked otherwise, circuit breakers are 80% duty rated. (B) Molded case circuit breakers are to be connected with 60 or 6-4 UL486B — Wire Connectors and Solderless Lugs for use with aluminum wire UL943 — Ground Fault Interrupters (for personnel protectors) UL1087 — Molded Case Switches 75°C wire for circuit breakers having a rated ampacity of 100 amperes or less. Circuit breakers having a rated ampacity greater than 100 amperes shall only be cabled with 75°C cable unless otherwise indicated on the circuit breaker label. Exceptions to this rule are outlined in the article 110-14 C(1)(2) of the 2005 National Electric Code. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog PD6, PXD6, HPD6, HPXD6, CPD6 RD6, RXD6, HRD6, HRXD6, SPD6, SHPD6 HHLD6, CLD6, CMD6, CND6 SCLD6, SCMD6, SCND6, CPD6 UL50 — Cabinets and Boxes UL869 — Service Equipment NEMA AB-1 — Molded Case Circuit Breakers and Molded Case Switches CSA–C22.2 No. 5, C22.2 No. 14 햲 Interrupting ratings are not limited to the values or groups of values listed. However, the values listed are minimum values for the class specified. 햳 Single-unit or duplex construction must be specified. 햴 Use minimum frame size for ampere rating. Molded Case Circuit Breakers Catalog Numbering System Selection/Application If used on 250A frame and above means non-interchangeable trip breaker with factory assembled frame and trip. Solid state trip and current limiting (S or C in first character) are non-interchangeable only, and the “X” is omitted. X D Trip Unit Type — Omitted – Thermal-Magnetic S — Sensitrip® Electronic Trip Sentron Series Type/Interrupting Range — Omitted – Standard Rating H — High IC Rating HH — Extra High IC Rating C — Highest IC Rating and Current Limiting Frame Identifier E — Type ED F — Type FD J — Type JD L — Type LD LM — Type LMD M N P R T — — — — — Type Type Type Type Type MD ND PD RD TD Maximum Voltage 2 — 240 Vac 4 — 480 Vac 6 — 600 Vac Number of Poles 1 2 3 9 used to indicate the max. functions for an electronic trip circuit breaker (always 3 poles) 6 (Specific Application Type) B — Standard 40°C Breaker M — Calibrated for 50°C Application F — Frame Only T — 40°C Trip Unit Only W — 50°C Trip Unit Only S — Molded Case Switch L — Low Instantaneous Range ETI Breaker A — Standard Range ETI Breaker H — High Instantaneous Range ETI Breaker MOLDED CASE CIRCUIT BREAKERS Maximum Continuous Current Rating ED Frame — 015, 020, 025, 030, 035, 040, 045, 050, 060, 070, 080, 090, 100, 110, 125 FD Frame — 070, 080, 090, 100, 110, 125, 150, 175, 200, 225, 250 JD Frame — 200, 225, 250, 300, 350, 400 LD Frame — 250, 300, 350, 400, 450, 500, 600 LMD Frame — 500, 600, 700, 800 MD Frame — 500, 600, 700, 800 ND Frame — 900, 100 (1000A), 120 (1200A) PD Frame — 120 (1200A), 140 (1400A), 160 (1600A) RD Frame — 160 (1600A), 180 (1800A), 200 (2000A) TD Frame — 2000, 2500, 3200 Suffix L — where applicable indicates a breaker shipped with line/loads lugs installed A — used with a switch to show automatic self protection Y — 400 Hertz H — 100% rated P — Load side lugs only NOTE: — Position omitted if not used. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-5 VL Molded Case Circuit Breakers Catalog Numbering System Selection/Application Interrupting Class N — Normal H — High L — Very High C — Trip Unit Only Frame Family G — Type GG E — Type EG D — Type DG F — Type FG J — Type JG L — M— N— P — Type LG Type MG Type NG Type PG Breaker Type G — Global (UL, IEC, CE, CSA, NOM) T — Trip Unit Only (Global) H — 100% rated X — Non-Interchangeable M — Motor Circuit Protector S — Molded Case Switch J — 240V only rated, Non-interchangeable only Y — 100% rated, Non-interchangeable N — Naval Number of Poles 1, 2, 3, 4, 5 (4P w/ neutral protection) MOLDED CASE CIRCUIT BREAKERS 6 Trip Unit B — Thermal Magnetic, standard 40° C ambient C — Thermal Magnetic, calibrated for 50° C ambient (non-UL) D — Electronic w/ LCD, LSI, 3P or 4P (neutral protected) E — Electronic w/ LCD, LSIG, 3P/4W (selectable residual or return type ground fault protection) F — Frame only, without trip unit H — Magnetic only, Motor Circuit Protector - High instantaneous range L — Magnetic Only, Motor Circuit Protector - Low instantaneous range M — Magnetic Only, Motor Circuit Protector - Standard instantaneous range N — Electronic LI, 3P or 4P (neutral protected) P — Electronic LSI, 3P or 4P (neutral protected) S — Molded Case Switch U — Electronic, LSIG, 3P/4W or 4P, residual ground fault protection X — Electronic, LIG, 3P/4W or 4P, residual ground fault protection Continuous Current Rating For GG use 015, 020, 025, 030, 035, 040, 050, 060, 070, 080, 090, 100, 110, 125 For EG use 015, 020, 025, 030, 035, 040, 050, 060, 070, 080, 090, 100, 110, 125 For DG use 050, 060, 070, 080, 090, 100, 110, 125, 150 For FG use 100, 110, 125, 150, 175, 200, 225, 250 For JG use 250, 300, 350, 400 For LG use 400, 500, 600 For MG use 600, 700, 800 For NG use 800, 900, 100 (1000A), 120 (1200A) For PG use 120 (1200A), 140 (1400A), 160 (1600A) Terminations B — Load End Standard (cu/al) Lugs L — Line & Load Standard (co/al) Lugs X — No Lugs (use only if accessory suffixes are to follow) Accessories Auxiliary and Alarm Switch Combinations Suffix Description A1 — 1 Alarm (includes 1NO & 1NC switch with a 2 Aux./1 Alarm Base, for frames EG to JG) A2 — 2 Aux (1NO & 1NC switch with a 3 Aux. Base, for frames EG to JG) A3 — 2 Aux + 1 Alarm (2NO & 2NC switches with a 2 Aux./1 Alarm Base, for frames EG to JG) A3 — 2 Aux + 2 Alarm (2NO & 2NC switches with a 2 Aux./2 Alarm Base, for frames LG to PG) A4 — 4 Aux (2NO & 2NC switches with a 4 Aux. Base, for frames LG to PG) Shunt Trips RB — 24 VDC RM — 48-60 VAC RC — 48-60 VDC RN — 110-127 VAC RD — 110-127 VDC RS — 208-277 VAC RE — 250 VDC RV — 380-600 VAC Under Voltage Releases UA — 12 VDC UN UB — 24 VDC UP UC — 48 VDC UR UD — 110-127 VDC US UE — 220-250 VDC UT UG — 60 VDC UU UV 6-6 — 110-127 VAC — 208 VAC — 220-250 VAC — 277 VAC — 380-415 VAC — 440-480 VAC — 600 VAC Note: A1 and A3 include 1NO and 1NC switch for alarm purposes, only one of these switches may be used as there is only one space for an alarm. LCD = Liquid Crystal Display LS = Long Delay & Short Delay trip functions LSI = Long Delay, Short Delay, & Instantaneous trip functions LSIG = Long Delay, Short Delay, Instantaneous, & Ground Fault trip functions GF = Ground Fault 3P = 3-pole 4W = 4-wire Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog VL Circuit Breakers Catalog Numbering System Selection If ordering factory-installed accessories or special modifications, you must order a 15-digit catalog number. See the examples below for a detailed explanation. The 15 digit number is achieved by placing X’s in positions not being occupied by an accessory/modification. Auxiliary Switch Example: HFG3B200L A2 XXXX Standard 9-digit Aux. Switch Completes Cat # Shunt Trip / UVR Example: HFG3B200L XX UN XX Standard 9-digit UVR Completes Cat # Shunt Trip / Auxiliary Switch Example: HFG3B200L A2 RN XX Standard 9-digit Aux. Switch Shunt Completes Trip Cat # Factory Modification Example: HFG3B200L XXXX Z1 Completes Cat # Custom Mod. 6 Standard 9-digit These places could designate an enclosure or special modification. Siemens will define the factory modification suffixes. MOLDED CASE CIRCUIT BREAKERS Non-Interchangeable Trip Breakers Example: HFX3B200L Standard 9-digit Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-7 Molded Case Circuit Breakers Reference Guide Selection/Application Thermal-Magnetic Trip Breakers Plug-In Breakers QT Page Poles Amperes, Continuous 1-Pole Volts (50/60 Hertz) AC Ratings 6 1-27, 1-29 1-27, 1-29 1-24, 1-29 1-24, 1-29 1-29 1, 2, 3 1, 2, 3 1, 2, 3 2 10–125 10–125 10–125 100–225 120/240 120/240 120/240 BLH HBL BQD, BQD6 NGB 6-18 6-18 6-18 6-21 6-22 2,3 1, 2, 3, 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 150–200 10–125 10–125 10–100 15–100 15–125 120/240 120/240 120/240 120/240 277 347 480/277 600/347 — 240 240 240 240 240 240 240 240 480/277 600/347 120V 10,000 10,000 22,000 65,000 — — 10,000 22,000 65,000 65,000 100,000 240V 10,000 10,000 22,000 65,000 100,000 10,000 10,000 22,000 65,000 65,000 100,000 25,000 — — — — — — — — 14,000 — — — — — — — — 10,000 14,000 480/277V — — — — — — — — — 14,000 600/347V — — — — — — — — — 10,000 14,000 Volts — 2-Pole — — — — — — — — — 250 Interrupting Rating — DC Amperes — — — — — — — — — 14,000 14,000 — 2.87 2.87 — — 7.00 3.56 3.56 — 4.50 — 25,000 250 15–30A — — — — — — — 3.75 — — — 15–60A 3.12 — — — — — — — — — — 55–125A — 3.12 3.12 3.12 3.12 3.00 3.75 — 3.75 4.50 — 1-Pole 1.00 1.00 1.00 1.00 — — 1.00 1.00 1.00 1.00 — 2-Pole 2.00 2.00 2.00 2.00 4.00 2.00 2.00 2.00 2.00 — 3-Pole 2.00 3.00 3.00 3.00 — 3.00 3.00 3.00 3.00 3.00 — Depth 2.06 2.37 2.37 2.37 2.37 2.34 2.37 2.37 2.69 2.23 — Thermal and Fixed Magnetic Trip ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Molded Case Switch — ⻫ — — — — — — — — — Undervoltage Trip — — — — — — — — — — — Shunt Trip — ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ Width MOLDED CASE CIRCUIT BREAKERS 1-25 BL — Dimensions in inches Individual Enclosures HQPPH QPJ — Height Accessories & Modifications HQP, HQPP 3-Pole 15–50A Overcurrent Devices Panelboard Breakers QPH, QPPH 1, 2 15–50 120/240 120/240 2-Pole UL Interrupting Rating — 277V Symmetrical RMS Amperes 347V DC QP, QPP Auxiliary Switch — — — — ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ Alarm Switch — — — — — — — — — ⻫ ⻫ Type 1 — Indoor Surface ⻫ ⻫ ⻫ ⻫ ⻫ — — — — — — Type 1 — Indoor, Flush — ⻫ ⻫ ⻫ ⻫ — — — — — — Type 3R — Outdoor-Rainproof — ⻫ ⻫ ⻫ ⻫ — — — — — — QP, QPH, HQP BL, BLH, HBL BQD, BQD6 For inches / millimeters conversion, see Application Data section. BQD6 Single Types 125A, CSA certified 10,000A @ 600Y/347V 15–70A only. QPP, QPPH, HQPP and HQPPH are special 2-pole configurations for load center mains. Amperage range = 125–225A, width = 4 in. 6-8 pole breakers available in ratings 10–70A only. 2-pole 120/240V AC only. Not applicable to types QPP and QPPH. Single pole circuit breakers available in ratings 15-70A only, Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 125A available as a 2-pole only. applicable to type HQPP and HQPPH. Fits only Siemens EQIII load centers. Breaker is 2 or 3 poles wide. Not Molded Case Circuit Breakers Reference Guide Selection/Application Thermal-Magnetic Trip Breakers General Purpose Breakers BQ BQH HBQ QJ2 QJH2 QJ2-H HQJ2-H CQD 6-26 6-26 6-26 6-28 6-28 6-28 6-28 6-29 6-30 1, 2, 3 1, 2, 3 1, 2, 3 2, 3 2, 3 2, 3 3 1, 2, 3 1, 2, 3 1-Pole 15–70 15–70 15–50 — — — — 15–100 15–125 2-Pole 15–125 15–100 15–70 — 15–100 15–125 3-Pole 15–100 15–100 15–100 100–225 15–100 15-125 120/240 120/240 120/240 — 277 347 3-Pole 240 240 240 480/277 600/347 120V 10,000 22,000 65,000 240V 10,000 22,000 480V — 600/347V Page Poles Amperes, Continuous 1-Pole Volts (50/60 Hertz) 2-Pole AC Ratings UL Interrupting Rating — Symmetrical RMS Amperes DC — — — — 240 240 240 65,000 — — — — 65,000 65,000 10,000 22,000 42,000 100,000 65,000 65,000 — — — — — — 14,000햴 25,000 240 — — — — — — 10,000햳 14,000 — — — — — — — 125/250 125/250 Interrupting Rating — DC Amperes — — — — — — — 14,000 14,000 3.75 3.75 4.00 — — — — 4.50 — Height Width 55–125A 4.00 4.00 4.00 — — — — 4.50 — 60–225A — — — 7.00 7.00 7.00 7.00 — — 1-Pole 1.00 1.00 1.00 — — — — 1.00 1.00 2-Pole 2.00 2.00 2.00 3.00 3.00 3.00 — 2.00 2.00 3-Pole 3.00 3.00 3.00 4.50 4.50 4.50 4.50 3.00 3.00 Depth 2.37 2.37 2.37 2.34 2.34 2.53 2.53 2.87 2.90 Thermal and Fixed Magnetic Trip ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Molded Case Switch ⻫ — — ⻫ — — — — — — — — — — — — ⻫ — Shunt Trip ⻫ ⻫ ⻫ ⻫햲 ⻫햲 ⻫햲 ⻫햲 ⻫ ⻫ Auxiliary Switch ⻫ ⻫ ⻫ ⻫햲 ⻫햲 ⻫햲 ⻫햲 ⻫ ⻫ Alarm Switch — — — ⻫ ⻫ — — ⻫ ⻫ Mechanical Interlock — — — ⻫ ⻫ ⻫ ⻫ — — Fungus Proofing (ref. page 6-84) ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Type 1 — Indoor Surface ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ Type 1 — Indoor, Flush ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ Type 3R — Outdoor-Rainproof ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ BQ, BQH, HBQ QJ2, QJH2, QJ2-H CQD MOLDED CASE CIRCUIT BREAKERS Undervoltage Trip 6 Individual Enclosures 60–225 — Dimensions in inches Accessories & Modifications 60–225 Volts — 2-Pole 15–50A Overcurrent Devices 60–225 NGG NGG For inches / millimeters conversion, see Application Data section. 햲 3-pole 햳 Type 햴 CQD breakers only (factory installed only). CQD6—CSA only. breakers are rated 14,000 KAIC at 480/277V. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-9 Molded Case Circuit Breakers Reference Guide Selection/Application Thermal-Magnetic Trip Breakers General Purpose Breakers Page Poles Amperes, Continuous Volts 50/60HZ AC Ratings UL Interrupt Rating Symmetrical RMS Amperes 220/240V IEC 947-2 380/415V 50/60HZ 500V DC MOLDED CASE CIRCUIT BREAKERS 6 Dimensions in inches Overcurrent Devices Accessories & Modifications Individual Enclosures 1-Pole 2-Pole 3-Pole 120V 240V 277V 347V 480V 600V Icu Ics Icu Ics Icu Ics 2-Pole, 250V DC Interrupting Ratings 3-Pole, 500V DC Interrupting Ratings Height 1-Pole 2-Pole 3-Pole 4-Pole Width Depth Thermal and Fixed Magnetic Trip Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connection Studs Electric Motor Operator Plug-In Mounting Assembly (3-4 Pole Only) Fungus Proofing (ref. page 6-84) Type 1 — Indoor Surface Type 1 — Indoor, Flush Type 3R — Outdoor-Rainproof Type 7 — Flammable Gas Atmosphere Type 9 — Combustion Dusttight Type 5, 12 — Lint, Fine Dust, Oils, Coolants Type 12K — Semi-Dusttight NEB, NEG 6-24, 6-32 1, 2, 3, 4 15–125 347 HEB, HEG 6-24, 6-32 1, 2, 3, 4 15–125 347 600/347 — 85,000 — — 35,000 22,000 85,000 42,000 40,000 20,000 — — 35,000 — 5.5 1.00 2.00 3.00 4.00 3.00 ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — ⻫ ⻫ — — — — — — — ED2 6-34 1, 2, 3 15–100 120 ED4 6-34 1, 2, 3 15–125 277 ED6 6-34 1, 2, 3 15–125 347 HED4 6-35 1, 2, 3 15–125 277 HHED6 6-35 2, 3 15–125 — CED6 6-35 2, 3 15–125 — 600/347 240 480 600 480 600 600 — 100,000 — — 65,000 25,000 100,000 50,000 70,000 35,000 — — 42,000 — 5.5 1.00 2.00 3.00 4.00 3.00 ⻫ — — 10,000 10,000 — — — — — — — — — — 5,000 — 6.34 1.00 2.00 3.00 — 4.00 ⻫ — — — 65,000 22,000 — 18,000 — ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — ⻫ ⻫ — — — — — — — — — — — 30,000 — 6.34 1.00 2.00 3.00 — 4.00 ⻫ — — — 100,000 — — 65,000 100,000 100,000 200,000 — 65,000 — — 30,000 — — — 25,000 142,000 65,000 200,000 18,000 — 18,000 100,000 65,000 — — 200,000 17,000 — — — 35,000 — — 200,000 19,000 — — — 18,000 — — — 15,000 — — — 30,000 30,000 — 30,000 18,000 — — 50,000 6.34 6.34 6.58 9.26 1.00 1.00 — — 2.00 2.00 2.00 2.00 3.00 3.00 3.00 3.00 — — — — 4.00 4.00 4.00 4.00 ⻫ ⻫ ⻫ ⻫ — — — — ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — ⻫ ⻫ For inches / millimeters conversion, see Application Data section. 1-pole only. 25,000 AIR at 277V AC/15-30A: 65,000 AIR at 277V 35-100A: AC. For DC UPS system application. 6-10 Single pole ED6 (15–30A) 30kA, (35–100A) 18 kA. CSA Only. pole HED4, 15-30A: 65,000 AIR at 240V AC; single pole HED4, 35-100A: 25,000 AIR at 240V AC. NEG and HEG breakers are rated at 600/347V. Single Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1-pole NEG breaker is rated 85K @ 240V, 35K @ 277V and 22K @ 347V. 1-pole HEG breaker is rated 100K @ 240V, 65K @ 277V and 25K @ 347V. Molded Case Circuit Breakers Reference Guide Selection/Application Thermal-Magnetic Trip Breakers Page Poles Amperes, Continuous Volts 50/60HZ Ratings Dimensions in inches Overcurrent Devices JD6-A, JXD6-A HJD6-A, HHJD6-A, HJXD6-A HHJXD6-A CJD6 6-37 2, 3 70–250 6-38 2, 3 70-250 6-38 2, 3 70-250 6-38 2, 3 70–250 6-40 2, 3 200-400 6-40 2, 3 200-400 6-41 2, 3 200-400 6-41 2, 3 200-400 6-41 2, 3 200-400 600 600 600 600 240 600 600 600 600 65,000 35,000 22,000 65,000 33,000 35,000 18,000 20,000 10,000 30,000 18,000 9.50 100,000 65,000 25,000 100,000 50,000 65,000 33,000 42,000 21,000 30,000 25,000 9.50 200,000 100,000 25,000 200,000 100,000 100,000 50,000 65,000 33,000 — — 14.12 200,000 200,000 100,000 — — — — — — 50,000 50,000 14.12 65,000 — — — — — — — — 30,000 — 11.00 65,000 35,000 25,000 65,000 33,000 40,000 20,000 20,000 15,000 30,000 25,000 11.00 100,000 65,000 35,000 100,000 50,000 65,000 33,000 42,000 21,000 30,000 35,000 11.00 200,000 100,000 50,000 200,000 100,000 100,000 50,000 65,000 33,000 — — 11.00 200,000 150,000 100,000 — — — — — — 50,000 50,000 17.86 4.50 4.50 4.50 4.50 7.50 7.50 7.50 7.50 7.50 4.00 — ⻫ ⻫ 4.00 — ⻫ — 4.00 — ⻫ — 4.00 — ⻫ ⻫ 4.00 — ⻫ — 4.00 — ⻫ — 4.00 — ⻫ ⻫ 4.00 — ⻫ ⻫ 4.00 — ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — — — Type 5, 12 — Lint, Fine Dust, Oils, Coolants ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Type 12K — Semi-Dusttight ⻫ ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ — For inches / millimeters conversion, see Application Data section. For DC UPS application. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-11 MOLDED CASE CIRCUIT BREAKERS Individual Enclosures JXD2-A 6 Accessories & Modifications 2-Pole 3-Pole 240V UL 480V AC 600V Interrupt Rating Symmetrical RMS Icu 220/240V Amperes Ics IEC60947-2 Icu 380/415V 50/60HZ Ics Icu 500V Ics 2-Pole 250V DC Interrupting Ratings DC 3-Pole, 500V DC Interrupting Ratings Height 2-Pole Width 3-Pole Depth Thermal and Fixed Magnetic Trip Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip Only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connection Studs Electric Motor Operator Plug-In Mounting Assembly Fungus Proofing (ref. page 6-84) Type 1 — Indoor Surface Type 1 — Indoor, Flush Type 3R — Outdoor-Rainproof Type 7 — Flammable Gas Atmosphere Type 9 — Combustion Dusttight General Purpose Breakers FD6A, HFD6, HHFD6, FXD6A HFXD6 HHFXD6 CFD6 Molded Case Circuit Breakers Reference Guide Selection/Application Thermal-Magnetic Trip Breakers Page Poles Amperes, Continuous Volts 50/60 HZ UL AC Interrupt Rating Symmetrical RMS Amperes Ratings 220/240V IEC 947-2 380/415V 50/60HZ 500V DC MOLDED CASE CIRCUIT BREAKERS 6 Overcurrent Devices Accessories & Modifications Individual Enclosures 2-Pole 250V DC Interrupting Ratings 3-Pole, 500V DC Interrupting Ratings Height Width Depth Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip Only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connection Studs Electric Motor Operator Plug-In Mounting Assembly Fungus Proofing (ref. page 6-84) Type 1 — Indoor Surface Type 1 — Indoor, Flush Type 3R — Outdoor-Rainproof Type 5, 12 — Lint, Fine Dust, Oils, Coolants Type 7 — Flammable Gas Atmosphere Type 9 — Combustion Dusttight Type 12K — Semi-Dusttight 2-Pole 3-Pole 240V 480V 600V Icu Ics Icu Ics Icu Ics General Purpose Breakers LD6, HLD6, HHLD6, LXD6 HLXD6 HHLXD6 6-44 6-45 6-45 2, 3 2, 3 2, 3 250-600 250-600 250-600 CLD6 6-45 2, 3 450-600 LMD6, LMXD6 6-48 2, 3 500-800 HLMD6, HLMXD6 6-49 2, 3 500-800 MD6, MXD6 6-51 2, 3 500-800 HMD6, HMXD6 6-52 2, 3 500-800 CMD6 6-52 3 400-800 600 600 600 600 600 600 600 600 600 65,000 35,000 25,000 65,000 33,000 40,000 20,000 30,000 15,000 30,000 35,000 11.00 7.50 4.00 100,000 65,000 35,000 100,000 50,000 65,000 33,000 42,000 21,000 30,000 11.00 7.50 4.00 — 200,000 100,000 50, 000 200,000 100,000 100,000 50, 000 65, 000 33, 000 — — 11.00 7.50 4.00 — 200,000 150,000 100,000 — — — — — — 50, 000 50, 000 17.86 7.50 4.00 65,000 50,000 25,000 65,000 33,000 40,000 20,000 30,000 15,000 30,000 25,000 16.00 7.50 4.59 100,000 65,000 50,000 100,000 50,000 65,000 33,000 42,000 21,000 30,000 50,000 16.00 7.50 4.59 65,000 50,000 25,000 65,000 33,000 40,000 20,000 30,000 15,000 30,000 25,000 16.00 9.00 6.19 100,000 65,000 50,000 00,000 50,000 65,000 33,000 42,000 21,000 30,000 50,000 16.00 9.00 6.19 — 200,000 100,0001 65,0001 200,000 100,000 100,000 50,000 65,0001 33,000 30,0001 50,000 16.00 9.00 6.19 — — — — — — — — — — — — — — — — — — — — — — — — — — — — For inches / millimeters conversion, see Application Data section. For DC UPS application. 6-12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Molded Case Circuit Breakers Reference Guide Selection/Application Thermal-Magnetic Trip Breakers Page Poles Amperes, Continuous Volts 50/60 HZ UL Ratings AC Interrupt Rating Symmetrical RMS Amperes 220/240V IEC 947-2 380/415V 50/60HZ 500V DC Dimensions in inches Overcurrent Devices Accessories & Modifications 2-Pole 250V DC Interrupting Ratings 3-Pole, 500V DC Interrupting Ratings Height Width Depth Circuit breakers require Connect-all mounting block. Dimensions shown are for circuit breaker only. HPD6, HPXD6 6-59 3 1200-1600 600 100,000 65,000 50,000 100,000 50,000 65,000 17,000 42,000 21,000 30,000 50,000 16.00 9.00 6.19 ⻫ — CPD6 6-59 3 1200-1600 600 200,000 100,000 65,000 200,000 100,000 100,000 25,000 65,000 17,000 30,000 50,000 16.00 9.00 6.19 ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — — — — — ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — — — — — ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — — — — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ — Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — — — — — Type 12K — Semi-Dusttight ⻫ ⻫ ⻫ — — — MOLDED CASE CIRCUIT BREAKERS Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip Only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connections Studs Electric Motor Operator Plug-in Mounting Assembly Fungus Proofing (ref. page 6-84) Mounting Block (required) Type 1 — Indoor Surface Type 1 — Indoor, Flush Type 3R — Outdoor-Rainproof Type 7 — Flammable Gas Atmosphere Type 9 — Combustion Dusttight PD6, PXD6 6-59 3 1200-1600 600 65,000 50,000 25,000 65,000 33,000 40,000 10,000 30,000 8,000 30,000 25,000 16.0 9.00 6.19 ⻫ — 6 Individual Enclosures 3-Pole 240V 480V 600V Icu Ics Icu Ics Icu Ics General Purpose Breakers ND6, HND6, NXD6 HNXD6 CND6 6-55 6-56 6-56 2, 3 2, 3 3 800-1200 800-1200 800-1200 600 600 600 65,000 100,000 200,000 50,000 65,000 100,000 25,000 50,000 65,000 65,000 100,000 200,000 50,000 100,000 33,0001 40,0001 65,000 100,000 20,00011 33,000 50,000 30,000 42,000 65,000 15,0001 21,000 33,000 30,000 30,000 30,0001 25,00011 50,000 50,000 16.00 16.00 16.00 9.00 9.00 9.00 6.191 6.19 6.19 ⻫ ⻫ ⻫ — — — For inches / millimeters conversion, see Application Data section. For DC UPS application. design. 3-pole design. 2-pole Requires Connect-all mounting assembly. Dimensions shown are for circuit breaker only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-13 Molded Case Circuit Breakers Reference Guide Thermal-Magnetic Trip Breakers & Electronic Trip Breakers Page Poles Amperes, Continuous Volts 50/60 HZ Ratings Dimensions in inches Accessories & Modifications MOLDED CASE CIRCUIT BREAKERS 6 Overcurrent Devices Individual Enclosures 3-Pole 240V UL 480V 600V AC Interrupt Rating Icu 220/240V Symmetrical RMS Ics Amperes IEC60947-2 Icu 380/415V 50/60HZ Ics Icu 500V Ics 2-Pole 250V DC Interrupting Ratings DC 3-Pole, 500V DC Interrupting Ratings Height Width 3-Pole Depth Solid State Trip Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip Only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connections Studs Electric Motor Operator Plug-In Mounting Assembly Fungus Proofing (ref. page 6-84) Mounting Block (required) Type 1 — Indoor Surface Type 1 — Indoor, Flush Type 3R — Outdoor-Rainproof Type 7 — Flammable Gas Atmosphere Type 9 — Combustion Dusttight Selection General Purpose Breakers HRD6, RD6, RXD6 HRXD6 6-62 6-62 3 3 1600-2000 1600-2000 600 600 65,000 100,000 50,000 65,000 25,000 50,000 65,000 100,000 33,000 50,000 40,000 65,000 10,000 17,000 30,000 42,000 8,000 21,000 30,000 30,000 25,000 50,000 16.00 16.00 9.00 9.00 6.19 6.19 — — ⻫ ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — — — — Solid State Trip Circuit Breakers SJD6 6-42 3 200-400 600 65,000 35,000 25,000 SHJD6 6-42 3 200-400 600 100,000 65,000 35,000 SCJD6 6-42 3 200-400 600 200,000 150,000 100,000 SLD6 6-46 3 300-600 600 65,000 35,000 25,000 SHLD6 6-46 3 300-600 600 100,000 65,000 35,000 SCLD6 6-46 3 300-600 600 200,000 150,000 100,000 11.00 7.50 4.00 ⻫ — — 11.00 7.50 4.00 ⻫ — — 17.86 7.50 4.00 ⻫ — — 11.0 7.50 4.00 ⻫ — — 11.00 7.50 4.00 ⻫ — — 17.86 7.50 4.00 ⻫ — — — ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — — — — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — — — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ ⻫ — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — — — Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Type 12K — Semi-Dusttight — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ For inches / millimeters conversion, see Application Data section. Requires Connect-all mounting assembly. Dimensions shown are for circuit breaker only. 6-14 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Molded Case Circuit Breakers Reference Guide Selection Electronic Trip Breakers Solid State Trip Circuit Breakers SMD6 Page Ratings AC Interrupt Rating Symmetrical RMS Amperes Dimensions in inches Height Width Depth Overcurrent Devices Solid State Trip Accessories & Modifications SHTD6 6-53 3 600800 600 200,000 100,000 65,000 — — — — 16.00 9.00 6.19 6-57 3 8001200 600 65,000 50,000 25,000 — — — — 16.00 9.00 6.19 6-57 3 8001200 600 100,000 65,000 50,000 — — — — 16.00 9.00 6.19 6-57 3 8001200 600 200,000 100,000 65,000 — — — — 16.00 9.00 6.19 6-60 3 12001600 600 65,000 50,000 25,000 — — — — 16.00 9.00 6.19 6-60 3 12001600 600 100,000 65,000 50,000 — — — — 16.00 9.00 6.19 6-64 3 20003200 600 85,000 65,000 50,000 — — — — 27.5 14.12 11.38 6-64 3 20003200 600 150,000 100,000 85,000 — — — — 27.5 14.12 11.38 6-64 3 20003200 600 200,000 150,000 100,000 — — — — 27.5 14.12 11.38 ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — — ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ — — — — ⻫ ⻫ ⻫ ⻫ ⻫ — ⻫ — ⻫ ⻫ — — — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — ⻫ — — — — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — ⻫ — — — — — ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — ⻫ — — — — — Type 5, 12 — Lint, Fine Dust, Oils, Coolants ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — — — — Type 12K — Semi-Dusttight ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ — — — — — For inches / millimeters conversion, see Application Data section. Requires connect-all mounting block assembly. Dimensions shown are for circuit breaker. Breaker has rating plugs which can be changed within each frame rating. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-15 MOLDED CASE CIRCUIT BREAKERS 6-53 3 600800 600 100,000 65,000 50,000 — — — — 16.00 9.00 6.19 SHHTD6 6 Individual Enclosures Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connection Studs Electric Motor Operator Plug-In Mounting Assembly Fungus Proofing (ref. page 6-84) Type 1 — Indoor Surface Type 1 — Indoor, Flush Type 3R — Outdoor-Rainproof Type 7 — Flammable Gas Atmosphere Type 9 — Combustion Dusttight STD6 SPD6 6-53 3 600800 3-Pole 600 240V 65,000 UL 480V 50,000 600V 25,000 Icu — 380/415V Ics — IEC60947-2 50/60HZ Icu — 690V Ics — 10.00 9.00 6.19 SHPD6 SHND6 SCND6 Poles Amperes, Continuous Volts 50/60HZ SHMD6 SCMD6 SND6 Molded Case Circuit Breakers Reference Guide Selection/Application Page Breaker Frame Family Continuous Amps Poles Max. Volts AC Breaker Type Interrupting Class Interrupting Rating RMS Symmetrical Amperes AC 50/60Hz Ratings DC Interrupting Ratings (UL) 햳 Dimensions in Inches MOLDED CASE CIRCUIT BREAKERS 6 Trip Unit Information Specific Application Breakers Accessories & Modifications EnclosuresA UL lCS/lCU 240Vac 480Vac 600Vac 220/240Vac 380/415Vac 690Vac 250Vdc (2-Pole) 500Vdc (3-Pole) 600Vdc (3-Pole) 750Vdc (4-Pole) 1-Pole 2-Pole 3-Pole 4-Pole Thermal-Magnetic Electronic Electronic with LCD Interchangeable Trip Unit Reverse Feed (w/Non-Interchangeable Trip) Communications Capability* Molded Case Switch Motor Circuit Protector 100% Rated 50°C CalibratedA Auxiliary Switch Alarm Switch Shunt Trip Undervoltage Release Mechanical Interlocks Electric Motor or Stored Energy Operator Rear Connecting Studs Plug-In Mounting Assy. w/Trip Interlock Draw-Out Assembly Handle Mechanism Options Fungus Proofing NEMA 1 – Indoor, Surface Mount NEMA 1 – Indoor, Flush Mount NEMA 3R – Outdoor, Rain Proof NEMA 4, 4X – Stainless Steel NEMA 7, 9 – Hazardous Locations NEMA 12 – Dust Terminal Shields Distribution Lugs Ground Sensor (Neutral Transformer) 6-30 GG 15–125A 1, 2, 3 600Y/347V NGG N 65 25 14 (600Y/347) 65/33 25/12.5 — 14 — — — 5.1H x 1W x 2.8D 5.1H x 2W x 2.8D 5.1H x 3W x 2.8D — ◆ ◆ 6-32 6-96 6-100 6-104 EG DG FG JG 15–125A 30–150A 40–250A 70–400A 1, 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 600Y/347V 600V 600V 600V NEG HEG NDG HDG LDG NFG HFG LFG NJG HJG LJG N H N H L N H L N H L 85 100 65 100 200 65 100 200 65 100 200 35 65 35 65 100 35 65 100 35 65 100 22 25 18 20 25 18 20 25 25 25 25 85/43 100/50 65/65 100/75 200/150 65/65 100/75 200/150 65/65 100/75 200/150 40/30 70/35 40/40 70/70 100/75 40/40 70/70 100/75 45/45 70/70 100/75 — — 12/6 12/6 12/6 12/6 12/6 12/6 12/6 15/8 15/8 35 42 30 30 30 30 30 30 30 30 30 — — 18 18 18 18 18 30 25 35 35 — — # # # # # # # # # — — # # # # # # # # # 5.5H x 1W x 3D — — 5.5H x 2W x 3D 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D 5.5H x 3W x 3D 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D 5.5H x 4W x 3D 6.9H x 5.5W x 3.4D 11H x 7.2W x 4.2D ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 햲 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. DC Interrupting Ratings are not applicable to electronic circuit breakers. * - Communications available via a COM 10 module using Profibus protocol. # - Consult Siemens for these applications. GG and EG are not VL family breakers and do not share common VL accessories. A - Consult Siemens for availability. 햳 6-16 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Molded Case Circuit Breakers Reference Guide Selection/Application Page Breaker Frame Family Continuous Amps Poles Max. Volts AC Breaker Type Interrupting Class Ratings Interrupting Rating RMS Symmetrical Amperes AC 50/60Hz DC Interrupting Ratings (UL) 햴 Dimensions in Inches Trip Unit Information EnclosuresA 1-Pole 2-Pole 3-Pole 4-Pole Thermal-Magnetic Electronic Electronic with LCD Interchangeable Trip Unit Reverse Feed (w/Non-Interchangeable Trip) Communications Capability 햲 Molded Case Switch Motor Circuit Protector 100% Rated 50°C CalibratedA Auxiliary Switch Alarm Switch Shunt Trip Undervoltage Release Mechanical Interlocks Electric Motor or Stored Energy Operator Rear Connecting Studs Plug-In Mounting Assy. w/Trip Interlock Draw-Out Assembly Handle Mechanism Options Fungus Proofing NEMA 1 – Indoor, Surface Mount NEMA 1 – Indoor, Flush Mount NEMA 3R – Outdoor, Rain Proof NEMA 4, 4X – Stainless Steel NEMA 7, 9 – Hazardous Locations NEMA 12 – Lint, Fine Dust, Oils, Coolant Terminal Shields Distribution Lugs Ground Sensor (Neutral Transformer) ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ MOLDED CASE CIRCUIT BREAKERS Accessories & Modifications lCS/lCU 240Vac 480Vac 600Vac 220/240Vac 380/415Vac 690Vac 250Vdc (2-Pole) 500Vdc (3-Pole) 600Vdc (3-Pole) 750Vdc (4-Pole) 6 Specific Application Breakers UL 6-108 6-112 6-116 6-120 LG MG NG PG 150–600A 200–800A 300–1200A 400–1600A 2, 3 2, 3, 4 2, 3, 4 3, 4 600V 600V 600V 600V NLG HLG LLG NMG HMG LMG NNG HNG LNG NPG HPG LPG N H L N H L N H L N H L 65 100 200 65 100 200 65 100 200 65 100 200 35 65 100 35 65 100 35 65 100 35 65 100 25 25 25 25 35 50 25 35 65 25 35 65 65/65 100/75 200/150 65/65 100/75 200/150 65/65 100/75 200/150 65/65 100/75 200/150 45/45 70/70 100/75 50/50 70/70 100/75 50/25 70/35 100/50 50/25 70/35 100/50 12/6 15/8 15/8 20/10 30/15 35/17 20/10 30/15 35/15 20/10 30/15 35/15 30 30 30 22 25 42 22 25 42 22 25 42 25 35 35 35 50 65 35 50 65 35 50 65 # # # # # # # # # # # # # # # # # # # # # # # # — — — 11H x 5.5W x 4.2D 16H x 7.5W x 4.7D 16H x 9W x 6.2D — 11H x 5.5W x 4.2D 16H x 7.5W x 4.7D 16H x 9W x 6.2D — 16H x 10W x 4.7D 16H x 12W x 6.2D ◆ ◆ 햲 Communications available via COMPRO or COMMOD modules using Profibus or Modbus protocol. 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. DC Interrupting Ratings are not applicable to electronic circuit breakers. # - Consult Siemens for these applications. A - Consult Siemens for availability. 햳 햴 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-17 Molded Case Circuit Breakers Panelboard Mounting with INSTA-WIRE Selection 1-Pole Bolt-On (120V AC)햲햶 Continuous Current Rating @ 40° C 10 15 20 25 30 35 40 45 50 60 70 Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR Catalog Number B110 B115햵 B120햵 B125 B130 B135 B140 B145■ B150 B160 B170 Catalog Number — B115H햵 B120H햵 B125H B130H B135H■ B140H B145H■ B150H B160H■ B170H■ List Price $ — 69.00 69.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 98.00 Catalog Number — B115HH햵 B120HH햵 B125HH■ B130HH B135HH■ B140HH B145HH■ B150HH■ B160HH■ B170HH■ 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 156.00 212.00 212.00 212.00 427.00 452.00 AC)햲햴햷 — B215H B220H B225H■ B230H B235H■ B240H B245H■ B250H B260H B270H■ B280H■ B290H■ B2100H B2110H■ B2125H — 156.00 156.00 156.00 156.00 156.00 156.00 156.00 156.00 156.00 240.00 342.00 342.00 342.00 861.00 905.00 — B215HH B220HH B225HH■ B230HH B235HH■ B240HH B245HH■ B250HH B260HH B270HH■ B280HH■ B290HH■ B2100HH B2100HH■ B2125HH■ 212.00 212.00 212.00 212.00 212.00 212.00 281.00 321.00 321.00 321.00 AC)햲햸 — — — — — — — — — — 2-Pole Bolt-On (Common-Trip 120/240V 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 B210 B215 B220 B225 B230 B235 B240 B245 B250 B260 B270 B280 B290 B2100 B2110■ B2125 MOLDED CASE CIRCUIT BREAKERS 6 2-Pole Bolt-On (Common-Trip 240V 15 20 30 40 50 60 70 80 90 100 B215R B220R B230R B240R■ B250R B260R B270R■ B280R■ B290R■ B2100R■ 3-Pole Bolt-On (Common-Trip 240V 10 15 20 25 30 35 40 45 50 60 70 80 90 100 B310 B315 B320 B325 B330 B335 P340 B345 B350 B360 B370 B380 B390 B3100 List Price $ 35.00 35.00 35.00 35.00 35.00 35.00 35.00 35.00 35.00 35.00 76.00 AC )햲햷 266.00 266.00 266.00 266.00 266.00 266.00 266.00 266.00 266.00 266.00 327.00 369.00 369.00 369.00 — B315H B320H B325H B330H B335H■ B340H B345H■ B350H B360H B370H B380H■ B390H■ B3100H — — — — — — — — — — Description 120V Shunt Trip 24V Shunt Trip 120V Auxiliary Switch 1-Pole Padlocking Device 2-Pole Padlocking Device 3-Pole Padlocking Device Handle Block Catalog Number add suffix...00S01■ add suffix...00S07■ add suffix...01■ 햳 ECPLD1 ECPLD2 ECQLD3 (bag of 10 pcs.) ECHBD1 ■ Built to order. Allow 2-3 weeks for delivery 햲 UL Listed for use with 60/75° wire through 125 amps, HACR rated. 120V AC Fluorescent Lighting. 햳 1A and 1B contacts. 6-18 — — — — — — — — — — — 400.00 400.00 400.00 400.00 400.00 400.00 400.00 400.00 400.00 486.00 570.00 570.00 570.00 MP-T / MP-HT / MP-MT Accessories List Price $ — 119.00 119.00 119.00 119.00 119.00 139.00 139.00 139.00 162.00 162.00 1-Pole — 290.00 290.00 290.00 290.00 355.00 355.00 355.00 355.00 355.00 581.00 655.00 655.00 655.00 655.00 2167.00 2-Pole 3-Pole — — — — — — — — — — — B315HH B320HH B325HH■ B330HH B335HH■ B340HH B345HH■ B350HH B360HH B370HH B380HH B390HH B3100HH — 503.00 503.00 503.00 503.00 503.00 613.00 613.00 613.00 613.00 655.00 771.00 771.00 771.00 Breaker Type BL, BLH BL, BLH HBL Dimensions Amperes L 15–50 39⁄16 55–125 33⁄4 15–125 33⁄4 D1 23⁄8 23⁄8 23⁄8 D2 3 3 3 Modifications Field/Factory Installed List Price $ Factory 141.00(adder) Factory 141.00(adder) Factory 83.00(adder) Field 10.10 Field 10.20 Field 98.00 Field 9.10 Description 400Hz Calibration 415V 50Hz Calibration Marine 50˚C Ambient Calibration Fungus Proofing 햴 UL Listed for use on 3-phase grounded “B” systems — 10,000 for this application. applications (SWD). 햵 UL Listed for frequent switching 햶 Shipped 12 per sleeve. 햷 Shipped 6 per sleeve. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog Number add suffix...Y햹 add suffix...E햺햻 List Price $ 8.00 (adder) No adder add suffix...M No adder add suffix...F 10.50 (adder per pole) 햸 Shipped 4 per sleeve. 햹 UL Listed 5KA IR. 햺 Not UL Listed. 햻 1 & 2 Poles only. 햽 Contact factory for availability Discount Schedule MCCB Molded Case Circuit Breakers Panelboard Mounting Circuit Breakers Selection ▪ UL Listed and CSA Certified ▪ HACR Rated ▪ Standard 1 inch per pole format with bolt-on design Ground-Fault Circuit Interrupters (Class A - 5mA)햳 Ground-fault circuit interrupters (GFCI) provide Class A ground fault protection. A GFCI is a device intended for personnel protection and will de-energize the circuit when a fault current to ground is 6 milliamperes or more. 10,000 A IR Breaker Type BLF/BLHF 1-Pole 120V AC Bolt-On BLF/BLHF 2-Pole 120/240V AC Bolt-On 22,000 A IR Ampere Rating Catalog Number List Price $ Catalog Number List Price $ 15 20 25 30 BF115 햲 BF120 햲 BF125 ■ BF130 344.00 344.00 344.00 344.00 BF115H햲 BF120H햲■ BF125H■ BF130H 683.00 683.00 683.00 683.00 15 20 30 40 50 60 BF215 BF220 BF230 BF240 BF250 BF260 410.00 410.00 410.00 410.00 410.00 410.00 BF215H BF220H BF230H BF240H BF250H BF260H 743.00 743.00 743.00 743.00 743.00 743.00 1-Pole GFCI 2-Pole GFCI Ground Fault Equipment Protection (30mA)햳 Ground fault circuit breakers provide protection of equipment from damaging line-to-ground fault currents by de-energizing the circuit for all ungrounded conductors of the faulted circuit. BLE/BLEH BE115 햲 BE120 햲 BE130 418.00 418.00 418.00 BE115H햲 BE120H햲 BE130H 683.00 683.00 683.00 15 20 30 40 50 60 BE215 BE220 BE230 BE240 BE250 BE260 ■ 549.00 549.00 549.00 549.00 549.00 549.00 BE215H BE220H BE230H BE240H BE250H BE260H■ 995.00 995.00 995.00 995.00 995.00 995.00 1-Pole Equipment Protection 2-Pole Equipment Protection MOLDED CASE CIRCUIT BREAKERS BLE/BLEH 2-Pole 120/240V AC Bolt-On 15 20 30 6 1-Pole 120V AC Bolt-On Arc-Fault Circuit Interrupters (AFCI)햳 Arc-fault circuit interrupters (AFCI) detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. An AFCI is a branch feeder device intended to mitigate the effects of arc-faults by de-energizing the circuit when an arc-fault is detected. BAF/BAFH 15 B115AF햲 361.00 B115AFH■햲 717.00 1-Pole 120V AC 20 B120AF햲 361.00 B120AFH■햲 717.00 BAF/BAFH 15 B215AF 454.00 B215AFH■ 820.00 20 B220AF 454.00 B220AFH■ 820.00 2-Pole 120/240V AC Description Catalog Number 1-Pole Padlock (on/off) ECPLD1 10.10 2-Pole Padlock (on/off) ECPLD2 10.20 Handle Block ECBX231M 햲 UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. Discount Schedule MCCB 2-Pole AFCI Wiring Diagrams QAF/QPF/QE Accessories ■ Built to order. Allow 2–3 weeks for delivery. 1-Pole AFCI List Price $ 9.70 햳 White line neutral (pigtail) must be connected to the panel neutral for the device to function. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-19 Molded Case Circuit Breakers Special Application Panelboard Mounting Breakers Switching Neutrals 햲 15 BG Selection 2-Wire Common Trip 20 30 BG215 ■ BG220 ■ BG230 ■ 123.00 123.00 123.00 10 10 10 — — — — — — BG 15 20 30 BG315 ■ BG320 ■ BG330 ■ 186.00 186.00 186.00 — — — 10 10 10 — — — 3-Wire Common Trip HID Lighting 햲 For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. BL 15 20 30 B115HID 햳■ B120HID 햳 B130HID ■ 45.00 45.00 45.00 10 10 10 — — — — — — BL 15 20 30 B215HID 햳■ B220HID 햳 B230HID ■ 96.00 96.00 96.00 — — — 10 10 10 — — — 1-Pole 2-Pole Switching Neutrals Tungsten Lighting For high wattage, tungsten-lamp loads in-rush currents above the instantaneous trip setting of a standard breaker. BL 1-Pole 15 20 B115T 햳 B120T 햳 62.00 62.00 10 10 — — — — — — — — Molded Case Switch 6 For applications that do not require overcurrent protection. BL 30 60 B230S B260S 68.00 80.00 — — MOLDED CASE CIRCUIT BREAKERS 2-Pole ■ Built to order. Allow 2–3 weeks for delivery. 햲 햳 HACR rated. UL Listed for frequent switching applications (SWD). 120V AC fluorescent lighting. 6-20 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers BQD 100A Frame Panelboard Mounting Circuit Breakers BQD Selection/Dimensions 2-Pole 480Y/277V AC– 125/250V DC 1-Pole 277V AC–125V DC Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 Catalog Number BQD115 BQD120 BQD125 BQD130 BQD135 BQD140 BQD145 ■ BQD150 BQD160 BQD170■ BQD180■ BQD190■ BQD1100■ List Price $ 128.00 128.00 128.00 128.00 128.00 128.00 128.00 128.00 128.00 247.00 247.00 247.00 247.00 Catalog Number BQD215 BQD220 BQD225 BQD230 BQD235 BQD240 BQD245 BQD250 BQD260 BQD270 BQD280 BQD290 BQD2100 3-Pole 480Y/277V AC List Price $ 289.00 289.00 289.00 289.00 289.00 289.00 289.00 289.00 289.00 588.00 588.00 588.00 588.00 Catalog Number BQD315 BQD320 BQD325 BQD330 BQD335 BQD340 BQD345 BQD350 BQD360 BQD370 BQD380 BQD390 BQD3100 List Price $ 513.00 513.00 513.00 513.00 513.00 513.00 513.00 513.00 513.00 699.00 699.00 699.00 699.00 BQD, BQD6 BQD6 CSA Certified 2-Pole 600/347V AC 1-Pole 347V AC List Price $ 128.00 128.00 128.00 128.00 128.00 128.00 128.00 128.00 128.00 247.00 Catalog Number BQD6115 BQD6120 BQD6125■ BQD6130 BQD6135■ BQD6140■ BQD6145■ BQD6150■ BQD6160■ BQD6170■ Catalog Number BQD6215 BQD6220 BQD6225■ BQD6230 BQD6235■ BQD6240■ BQD6245■ BQD6250■ BQD6260■ BQD6270■ List Price $ 289.00 289.00 289.00 289.00 289.00 289.00 289.00 289.00 289.00 588.00 Catalog Number BQD6315 BQD6320 BQD6325■ BQD6330 BQD6335■ BQD6340 BQD6345■ BQD6350 BQD6360 BQD6370 List Price $ 513.00 513.00 513.00 513.00 513.00 513.00 513.00 513.00 513.00 699.00 Interrupting Ratings BQD (UL) BQD6 (CSA) RMS Symmetrical Amperes (KA) Volts AC 480/ 120 240 277 277 1 2 3 1 2 3 65 — — 65 — — BQD Internal Accessories Control Voltage V AC 24 120 240 277 480 600 — — — — V DC — — — — — — 12 24 48 125 Maximum Voltage AC 240 240 DC 125 125 Shunt Trip Catalog Number BQDST24▲ BQDST120 BQDST240▲ BQDST277▲ BQDST480▲ BQDST600▲ BQDST12▲ BQDST24▲ BQDST48▲ BQDST125▲ — 65 65 — 65 65 List Price $ 636.00 636.00 636.00 636.00 636.00 636.00 636.00 636.00 636.00 636.00 Auxiliary Switch Catalog Number List Price $ BQDA1▲ 271.00 BQDA2▲ 540.00 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule MCCB 14 — — — — — — 14 14 — — — Shipping Weights Number of Poles Number per Carton Shipping Weight (lbs.) (ea.) 1 2 3 1/12/48 1/6/24 1/4/16 1.6 1.2 2.0 MOLDED CASE CIRCUIT BREAKERS Breaker Type Number of Poles BQD, BQD6 6 Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 3-Pole 600/347V AC Lugs For 60/70°C Wire Volts DC 347 600/ 347 125 125/ 250 — — — 10 — — — — — — 10 10 14 — — 14 — — — 14 — — 14 — BQD – Load End Only 15–40 #14–#6 AWG Cu #12–#6 AWG Al 45–100 #8–#1 AWG Cu #6–#1/0 AWG Al Shunt Trip and Auxiliary Switch Combinations Catalog Number List Price $ BQDST24AAS▲ 897.00 897.00 BQDST120AAS▲ BQDST240AAS▲ 897.00 BQDST277AAS▲ 897.00 BQDST480AAS▲ 897.00 BQDST600AAS▲ 897.00 BQDST12DAS▲ 897.00 BQDST24DAS▲ 897.00 BQDST48DAS▲ 897.00 BQDST125DAS▲ 897.00 Alarm Switch Catalog Number BQDBA▲ — Alarm and Auxiliary Switch Combination List Price $ 271.00 — Catalog Number List Price $ BQDA1BA 540.00 SWD HID HID Accessory rated for switching fluorescent lighting. rated at 277V AC. Not suitable for 3-phase delta 480V applications. HACR rated. rated at 480Y/277V AC. adds one pole space. Accessories pages 6-86 to 6-91 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-21 Molded Case Circuit Breakers NGB Frame Selection Type NGB (Panelboard Mount) 1-Pole Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 2-Pole Catalog Number NGB1B015B 햲 햳 NGB1B020B 햲 햳 NGB1B025B 햳 NGB1B030B 햳 NGB1B035B 햳 NGB1B040B 햳 NGB1B045B 햳 NGB1B050B 햳 NGB1B060B NGB1B070B NGB1B080B NGB1B090B NGB1B100B NGB1B110B NGB1B125B List Price $ 153.00 153.00 153.00 153.00 153.00 153.00 153.00 153.00 153.00 257.00 257.00 257.00 257.00 520.00 520.00 Catalog Number NGB2B015B 햳 NGB2B020B 햳 NGB2B025B 햳 NGB2B030B 햳 NGB2B035B 햳 NGB2B040B 햳 NGB2B045B 햳 NGB2B050B 햳 NGB2B060B NGB2B070B NGB2B080B NGB2B090B NGB2B100B NGB2B110B NGB2B125B 3-Pole List Price $ 479.00 479.00 479.00 479.00 479.00 479.00 479.00 479.00 479.00 635.00 635.00 635.00 635.00 1272.00 1272.00 Catalog Number NGB3B015B 햳 NGB3B020B 햳 NGB3B025B 햳 NGB3B030B 햳 NGB3B035B 햳 NGB3B040B 햳 NGB3B045B 햳 NGB3B050B 햳 NGB3B060B NGB3B070B NGB3B080B NGB3B090B NGB3B100B NGB3B110B NGB3B125B List Price $ 627.00 627.00 627.00 627.00 627.00 627.00 627.00 627.00 627.00 738.00 738.00 738.00 738.00 1613.00 1613.00 NGB Load lugs are included as standard. HACR rated. MOLDED CASE CIRCUIT BREAKERS 6 Shipping Weights Lugs For 60/75°C Wire Number of Poles Number per Carton Shipping Weight lbs. (kg) 1 2 3 1 1 1 0.9 (0.4) 1.9 (0.9) 2.9 (1.2) NGB Ampere Rating Wire Size Catalog Number 15–30A #14–#6 AWG Cu #12–#6 AWG Al Integral with breaker 35–125A #8-#1/0 AWG Cu #8-#2/0 AWG Al Integral with breaker List Price $ Interrupting Ratings (max. RMS symmetrical amperes kA) Breaker Type NGB Number of Poles 1 2, 3 UL489 Volts AC 120 100 — 240 — 100 277 25 — 347 14 — 480Y/277 — 25 600Y/347 — 14 Volts DC 125 14 — 125/250 — 14햴 IEC 60947-2 (lcs = 50% lcu) Volts AC Volts DC 240 415 125/250 25 — — 65 25 14 40°C, 50/60Hz. 햲 SWD 햳 HID rated. rated. only. 햴 2-pole 6-22 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Accessories for CQD 100A Frame, NGG and NGB 125A Frame햲 Selection Shunt Trip Control Voltage V AC V DC CQD, CQD6, NGG, NGB Catalog Number List Price $ 120 240 277 480 600 — — — — — CQDST120 CQDST240▲ CQDST277▲ CQDST480▲ CQDST600 636.00 636.00 636.00 636.00 636.00 — — — — 012 024 048 125 CQDST12 CQDST24 CQDST48 CQDST125 636.00 636.00 636.00 636.00 Auxiliary Switch Maximum Voltage AC DC Number of Contacts 240 240 125 125 1A–1B 2A–2B CQD, CQD6, NGG, NGB Catalog Number List Price $ CQDA1 CQDA2 271.00 540.00 CQD with Accessory Installed Alarm Switch Maximum Voltage AC DC CQD, CQD6, NGG, NGB Catalog Number 240 125 CQDBA List Price $ 271.00 Shunt Trip and Auxiliary Switch Combinations Shunt Trip Voltage CQDST24AAS▲ 897.00 120 CQDST120AAS▲ 897.00 240 CQDST240AAS▲ 897.00 277 CQDST277AAS▲ 897.00 480 CQDST480AAS▲ 897.00 600 CQDST600AAS▲ 897.00 12 CQDST12DAS▲ 897.00 24 CQDST24DAS▲ 897.00 48 CQDST48DAS▲ 897.00 125 CQDST125DAS▲ 897.00 DC MOLDED CASE CIRCUIT BREAKERS List Price $ 24 AC 6 CQD, CQD6, NGG, NGB Catalog Number Alarm and Auxiliary Switch Combinations For Breaker Catalog Number List Price CQD, CQD6, NGG, NGB CQDA1BA▲ 540.00 ▲ Built to order. Allow 6–8 weeks for delivery. 햲 Adds 1-pole space for accessory. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-23 Molded Case Circuit Breakers NEB & HEB Frame Selection Type NEB (Panelboard Mount) 1-Pole Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 2-Pole Catalog Number NEB1B015B 햲 햳 NEB1B020B 햲 햳 NEB1B025B 햳 NEB1B030B 햳 NEB1B035B 햳 NEB1B040B 햳 NEB1B045B 햳 NEB1B050B 햳 NEB1B060B NEB1B070B NEB1B080B NEB1B090B NEB1B100B NEB1B110B NEB1B125B List Price $ 282.00 282.00 282.00 282.00 282.00 282.00 282.00 282.00 282.00 321.00 321.00 321.00 321.00 710.00 710.00 Catalog Number NEB2B015B 햳 NEB2B020B 햳 NEB2B025B 햳 NEB2B030B 햳 NEB2B035B 햳 NEB2B040B 햳 NEB2B045B 햳 NEB2B050B 햳 NEB2B060B NEB2B070B NEB2B080B NEB2B090B NEB2B100B NEB2B110B NEB2B125B 3-Pole List Price $ 707.00 707.00 707.00 707.00 707.00 707.00 707.00 707.00 707.00 803.00 803.00 803.00 803.00 1771.00 1771.00 Catalog Number NEB3B015B 햳 NEB3B020B 햳 NEB3B025B 햳 NEB3B030B 햳 NEB3B035B 햳 NEB3B040B 햳 NEB3B045B 햳 NEB3B050B 햳 NEB3B060B NEB3B070B NEB3B080B NEB3B090B NEB3B100B NEB3B110B NEB3B125B List Price $ 883.00 883.00 883.00 883.00 883.00 883.00 883.00 883.00 883.00 1004.00 1004.00 1004.00 1004.00 2214.00 2214.00 Front view Back view HEB Type HEB (Panelboard Mount) MOLDED CASE CIRCUIT BREAKERS 6 1-Pole Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 2-Pole Catalog Number HEB1B015B 햲 햳 HEB1B020B 햲 햳 HEB1B025B 햳 HEB1B030B 햳 HEB1B035B 햳 HEB1B040B 햳 HEB1B045B 햳 HEB1B050B 햳 HEB1B060B HEB1B070B HEB1B080B HEB1B090B HEB1B100B HEB1B110B HEB1B125B List Price $ 394.00 394.00 394.00 394.00 394.00 394.00 394.00 394.00 394.00 467.00 467.00 467.00 467.00 980.00 980.00 Catalog Number HEB2B015B 햳 HEB2B020B 햳 HEB2B025B 햳 HEB2B030B 햳 HEB2B035B 햳 HEB2B040B 햳 HEB2B045B 햳 HEB2B050B 햳 HEB2B060B HEB2B070B HEB2B080B HEB2B090B HEB2B100B HEB2B110B HEB2B125B 3-Pole List Price $ 918.00 918.00 918.00 918.00 918.00 918.00 918.00 918.00 918.00 1044.00 1044.00 1044.00 1044.00 2030.00 2030.00 Catalog Number HEB3B015B 햳 HEB3B020B 햳 HEB3B025B 햳 HEB3B030B 햳 HEB3B035B 햳 HEB3B040B 햳 HEB3B045B 햳 HEB3B050B 햳 HEB3B060B HEB3B070B HEB3B080B HEB3B090B HEB3B100B HEB3B110B HEB3B125B List Price $ 1076.00 1076.00 1076.00 1076.00 1076.00 1076.00 1076.00 1076.00 1076.00 1198.00 1198.00 1198.00 1198.00 2433.00 2433.00 Load lugs are included as standard. HACR rated. Shipping Weights Lugs For 60/75°C Wire Number of Poles Number per Carton Shipping Weight lbs. (kg) 1 2 3 1 1 1 1.4 (0.5) 2.4 (0.9) 3.7 (1.4) NEB/HEB Ampere Rating Wire Size Catalog Number 15–100A #14–1/0 3TA1EG10 List Price $ 12.80 60–125A #6–2/0 3TA1EG30 12.80 Interrupting Ratings (max. RMS symmetrical amperes kA) Breaker Type NEB HEB Number of Poles 1 2, 3 UL489/CSA Volts AC 240 277 85 35 85 — 347 22 — 480 — 35 1 2, 3 100 100 25 — — 65 65 — 600Y/347 — 22 Volts DC 125/250 35 35 IEC 60947-2 Volts AC 240 85 85 — 25 42 42 100 100 (lcs = 50% lcu) Volts DC 415 125 — 35 40 — — 70 42 — 125/250 — 35 — 42 40°C, 50/60Hz. 햲 SWD 햳 HID rated. rated. 6-24 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories for NEG & HEG 125A Frame, NEB & HEB 125A Frame Selection Shunt Trip Control Voltage V AC V DC NEG, HEG, NEB, HEB Catalog Number List Price $ 110-240 380-600 24-60 125 — 24-60 STRER240 STREV600 STREM60D 636.00 636.00 636.00 Auxiliary Switch Maximum Voltage AC DC Number of Contacts 240 240 125 125 1A–1B 2A–2B NEG, HEG, NEB, HEB Catalog Number List Price $ ASKE2 ASKE3 271.00 540.00 Alarm Switch Maximum Voltage AC DC Number of Contacts 240 240 125 125 1A–1B 2A–2B NEG, HEG, NEB, HEB Catalog Number List Price $ ASKE1 ASKE5 271.00 540.00 Undervoltage Trip Control Voltage UVREM60▲ 636.00 120 UVREN120 636.00 240 UVRER240 636.00 480 UVREU480▲ 636.00 600 UVREV600▲ 636.00 636.00 DC 12 12 UVREA12AD▲ 24 24 UVREB24AD 636.00 48 UVREC48D▲ 636.00 125 UVRED125D▲ 636.00 250 UVREE250D▲ 636.00 MOLDED CASE CIRCUIT BREAKERS List Price $ 60 AC 6 NEG, HEG, NEB, HEB Catalog Number Alarm and Auxiliary Switch Combinations For Breaker NEG, HEG Catalog Number ASKE6 List Price $ 540.00 ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-25 Circuit Breakers Lug-In/Lug-Out with INSTA-WIRE Selection All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix “L” to catalog number. Consult Siemens for any additional charge. All standard circuit breakers are calibrated for 40(insert degree symbol)C maximum ambient application. 1-Pole Plug-In (120V AC) Continuous Current Rating @ 40° C 10 15 20 25 30 35 40 45 50 60 70 Type BQ Type BQH Type HBQ 10,000A IR 22,000A IR 65,000A IR Catalog Number BQ1B010 BQ1B015 BQ1B020 BQ1B025 BQ1B030 BQ1B035■ BQ1B040 BQ1B045■ BQ1B050 BQ1B060■ BQ1B070■ List Price $ 33.50 33.50 33.50 33.50 33.50 33.50 33.50 33.50 33.50 33.50 33.50 Catalog Number BQ1B010H BQ1B015H BQ1B020H BQ1B025H■ BQ1B030H BQ1B035H■ BQ1B040H BQ1B045H■ BQ1B050H BQ1B060H■ BQ1B070H■ List Price $ — 66.00 66.00 66.00 74.00 74.00 74.00 74.00 74.00 74.00 92.00 — BQ2B015H BQ2B020H BQ2B025H■ BQ2B030H BQ2B035H■ BQ2B040H BQ2B045H■ BQ2B050H BQ2B060H BQ2B070H■ BQ2B080H■ BQ2B090H■ BQ2B100H BQ2B110H BQ2B125H — 149.00 149.00 149.00 149.00 149.00 149.00 149.00 149.00 149.00 224.00 326.00 326.00 326.00 864.00 1112.00 Catalog Number HB1B010 HB1B015■ HB1B020■ HB1B025■ HB1B030■ HB1B035■ HB1B040■ HB1B045■ HB1B050■ HB1B060■ HB1B070■ List Price $ — 113.00 113.00 113.00 113.00 113.00 132.00 132.00 132.00 132.00 142.00 1-Pole 2-Pole Plug-In (Common-Trip 120/240V AC ) MOLDED CASE CIRCUIT BREAKERS 6 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 BQ2B010 BQ2B015 BQ2B020 BQ2B025 BQ2B030 BQ2B035 BQ2B040 BQ2B045 BQ2B050 BQ2B060 BQ2B070 BQ2B080 BQ2B090 BQ2B100 BQ2B110 BQ2B125 76.00 76.00 76.00 76.00 76.00 76.00 76.00 76.00 76.00 76.00 149.00 203.00 203.00 203.00 407.00 431.00 HB2B010■ HB2B015■ HB2B020■ HB2B025■ HB2B030■ HB2B035■ HB2B040■ HB2B045■ HB2B050■ HB2B060■ HB2B070■ HB2B080 HB2B090■ HB2B100 HB2B110■ HB2B125 276.00 276.00 276.00 276.00 276.00 276.00 276.00 276.00 338.00 338.00 552.00 624.00 624.00 624.00 1794.00 1794.00 2-Pole 3-Pole 2-Pole Plug-In (Common-Trip 240V AC) 15 20 30 40 50 60 70 80 90 100 BQ2H015 BQ2H020 BQ2H030 BQ2H040■ BQ2H050 BQ2H060 BQ2H070■ BQ2H080■ BQ2H090■ BQ2H100■ 203.00 203.00 203.00 203.00 203.00 203.00 269.00 306.00 306.00 306.00 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3-Pole Plug-In (Common-Trip 240V AC) 10 15 20 25 30 35 40 45 50 60 70 80 90 100 BQ3B010 BQ3B015 BQ3B020 BQ3B025■ BQ3B030 BQ3B035■ BQ3B040 BQ3B045■ BQ3B050 BQ3B060 BQ3B070 BQ3B080 BQ3B090 BQ3B100 254.00 254.00 254.00 254.00 254.00 254.00 254.00 254.00 254.00 254.00 311.00 351.00 351.00 351.00 — BQ3B015H BQ3B020H BQ3B025H■ BQ3B030H BQ3B035H BQ3B040H BQ3B045H BQ3B050H BQ3B060H BQ3B070H BQ3B080H■ BQ3B090H■ BQ3B100H — 381.00 381.00 381.00 381.00 381.00 381.00 381.00 381.00 381.00 463.00 543.00 543.00 543.00 UL Catalog Number Field/Factory Installed List Price $ add suffix...00S01■ Factory 141.00(adder) add suffix...00S07■ Factory 141.00(adder) add suffix...01■ Factory 83.00(adder) ECPLD1 Field 10.10 ECPLD2 Field 10.20 ECQLD3 (Pkg of 10) Field 98.00 ECHBD1 Field 9.10 Listed for use with 60/75° wire through 125 amps, HACR rated. 1A and 1B contacts. UL Listed for use on 3-phase grounded “B” systems — 10,000 for this application. 6-26 480.00 480.00 480.00 480.00 480.00 480.00 584.00 584.00 584.00 584.00 624.00 734.00 734.00 734.00 Factory Modifications MP-T / MP-HT / MP-MT Accessories Description 120V Shunt Trip 24V Shunt Trip 120V Auxiliary Switch 1-Pole Padlocking Device 2-Pole Padlocking Device 3-Pole Padlocking Device Handle Block HB3B010 HB3B015■ HB3B020■ HB3B025 HB3B030 HB3B035 HB3B040 HB3B045 HB3B050 HB3B060 HB3B070■ HB3B080■ HB3B090■ HB3B100 UL Description Line Side Lugs Quick Connect Lug 400Hz Calibration 415V 50Hz Calibration Marine 50˚ C Ambient Calibration Fungus Proofing Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. Shipped 12 per sleeve. Shipped 6 per sleeve. Shipped 4 per sleeve. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog Number add suffix...L add suffix...QX add suffix...Y add suffix...E List Price $ Consult Siemens 7.50 (adder per pole) 8.00 (adder) No adder add suffix...M No adder add suffix...F UL Listed 5KA IR. Not UL Listed. 1 & 2 Poles only. 10.50 (adder per pole) ■ Built to order. Allow 2-3 weeks for delivery Discount Schedule MCCB Molded Case Circuit Breakers DIN Rail Mounted Circuit Breakers Selection/Dimensions 1-Pole DIN Rail (120V AC) “Interrupting Ratings (KA) (RMS Symmetrical Amperes)” Volts AC Breaker Type “BQXD 1-Pole 120V DIN Rail” Ampere Rating 10 15 20 25 30 35 40 45 50 60 10 15 20 25 30 35 40 45 50 60 Catalog Number BQ1B010QLD BQ1B015QLD BQ1B020QLD BQ1B025QLD BQ1B030QLD BQ1B035QLD BQ1B040QLD BQ1B045QLD BQ1B050QLD BQ1B060QLD BQ1B010QXD BQ1B015QXD BQ1B020QXD BQ1B025QXD BQ1B030QXD BQ1B035QXD BQ1B040QXD BQ1B045QXD BQ1B050QXD BQ1B060QXD 2-Pole DIN Rail (120/240V AC) BQ2B010QLD “BQXD 10 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TA1Q1 TA1Q1 TA1Q1 Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect 76.00 76.00 76.00 76.00 76.00 76.00 76.00 76.00 76.00 76.00 91.00 91.00 91.00 91.00 91.00 91.00 91.00 91.00 91.00 91.00 120 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 120/240 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 BQ1B015QLD BQ2B015QLD BQ1B015QXD BQ2B015QXD MOLDED CASE CIRCUIT BREAKERS BQ2B015QLD BQ2B020QLD BQ2B025QLD BQ2B030QLD BQ2B035QLD BQ2B040QLD BQ2B045QLD BQ2B050QLD BQ2B060QLD BQ2B010QXD BQ2B015QXD BQ2B020QXD BQ2B025QXD BQ2B030QXD BQ2B035QXD BQ2B040QXD BQ2B045QXD BQ2B050QXD BQ2B060QXD List Price $ 33.50 33.50 33.50 33.50 33.50 33.50 33.50 33.50 33.50 33.50 39.50 39.50 39.50 39.50 39.50 39.50 39.50 39.50 39.50 39.50 6 2-Pole 15 120/240V 20 DIN Rail” 25 30 35 40 45 50 60 10 15 20 25 30 35 40 45 50 60 Load Side Connector TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TA1Q1 TA1Q1 TA1Q1 Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Lugs-For Use with BQ, BQH, HBQ햹 Circuit Breaker Amp. Rtg. Line Side Cab. Per Lug 10–40 1 1 1 1 #16–#6 Cu #12–#6 Al #8–#1 Cu #6–#1/0 Al 2 1 1 1 1 1 1 1 1 1 1 1 1 #16 Cu #14–#10 Cu #12–#10 Al #14–#6 Cu #12–#10 Al #8–#6 Cu #8–#4 Al #8–#4 Cu #8–#2 Al #4–#1/0 Cu #2–#1/0 Al #2–#1/0 Cu #1/0–#2/0 Al 45–100 Load Side 10 15–20 25–35 40–50 55–70 80–100 110–125 Lug Wire Range AWG Catalog Number TC1Q1 햲 햳 2.60 TA1Q1 2.60 Connectors are Supplied with Circuit Breaker are UL Listed for 60°/75°C conductors. Also CSA Listed. has steel construction. Discount Schedule MCCB Amperes L D1 D2 BQ, BQH BQ, BQH HBQ BQXD 15–50 55–125 15–125 15–60 33⁄4 4 4 41⁄2 23⁄8 23⁄8 23⁄8 23⁄8 3 3 3 3 Protects against accidental contact with lugs–1 per lug. Fits line and load end. ■ Built to order. Allow 2–3 weeks for delivery. 햳 Connector Dimensions (inches) Breaker Type Finger Safe Terminal Shield For inches / millimeters conversion, see Application Data section. 햲 Terminals List Price $ (Qty. 6) Catalog Number Qty List Price $ each BQFS2 2 2.10 BQFS1K 1000 1.40 Enclosures 햴 Surface Type Catalog Number 햷 1 EB3100S 햴햸 189.00 3R WB3100 249.00 mounted indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. 햵 Discount Schedule B. 햶 Does not include circuit breaker. Order circuit breaker separately. 햷 Neutral included in enclosure. 햸 Enclosure will not accept circuit breakers with shunt trips or auxiliary switches installed. List Price $ 햵햶 햹 Type BQXD uses TA1Q1 or TC1Q1 lugs on line side of circuit breaker. Enclosures Section 5 Accessories pages 6-86 to 6-91 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-27 Molded Case Circuit Breakers QJ 225A Frame Selection/Dimensions Type QJ2 Ordering Information 2-Pole 3-Pole Continuous Current Rating @ 40°C 240V AC Catalog Number List Price $ 240V AC Catalog Number List Price $ 060 070 080 090 100 110 125 150 175 200 225 QJ22B060■ QJ22B070■ QJ22B080■ QJ22B090■ QJ22B100 QJ22B110■ QJ22B125 QJ22B150 QJ22B175 QJ22B200 QJ22B225 422.00 422.00 422.00 422.00 422.00 422.00 422.00 422.00 422.00 422.00 422.00 QJ23B060 QJ23B070 QJ23B080■ QJ23B090■ QJ23B100 QJ23B110 QJ23B125 QJ23B150 QJ23B175 QJ23B200 QJ23B225 1106.00 1106.00 1106.00 1106.00 1106.00 1106.00 1106.00 1106.00 1106.00 1106.00 1106.00 QJH22B060■ QJH22B070■ QJH22B080■ QJH22B090■ QJH22B100■ QJH22B110■ QJH22B125 QJH22B150 QJH22B175■ QJH22B200 QJH22B225 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 QJH23B060■ QJH23B070■ QJH23B080■ QJH23B090■ QJH23B100 QJH23B110 QJH23B125 QJH23B150 QJH23B175 QJH23B200 QJH23B225 1548.00 1548.00 1548.00 1548.00 1548.00 1548.00 1548.00 1548.00 1548.00 1548.00 1548.00 Type QJH2 060 070 080 090 100 110 125 150 175 200 225 Type QJ2H QJ22B060H■ QJ22B070H■ QJ22B080H■ QJ22B090H■ QJ22B100H■ QJ22B110H■ QJ22B125H QJ22B150H QJ22B175H■ QJ22B200H QJ22B225H 1255.00 1255.00 1255.00 1255.00 1255.00 1255.00 1255.00 1255.00 1255.00 1255.00 1255.00 QJ23B060H■ QJ23B070H■ QJ23B080H■ QJ23B090H■ QJ23B100H QJ23B110H■ QJ23B125H QJ23B150H QJ23B175H QJ23B200H QJ23B225H 1964.00 1964.00 1964.00 1964.00 1964.00 1964.00 1964.00 1964.00 1964.00 1964.00 1964.00 — — — — — — — — — — — — — — HQJ23B100H HQJ23B110H HQJ23B125H HQJ23B150H HQJ23B175H HQJ23B200H HQJ23B225H ▲2234.00 ▲2234.00 ▲2234.00 2234.00 ▲2234.00 2234.00 ▲2234.00 50° C Calibration - See page 6-84. 400HZ. - See page 6-84. Shipping Weights QJ2, QJH2, QJ2H, HQJ2H Number of Poles Number per Carton Shipping Weight (lbs.) 2 3 10 10 30 41 Lugs For 75°C Wire Catalog Number Lug Body Lug Wire Range TA1Q300 Al (1) #6—300 kcmil Cu (1) #4—300 kcmil Al TC1Q250 Cu (1) #6—250 kcmil Cu Enclosures (Neutral Included) Type Catalog Number List Price $ 1 3R (2-pole) 3R (3-pole) EB3225(S)(F) WB2225 WB3225 226.00 418.00 459.00 UL 489 Interrupting Ratings Breaker Type AIR @ 240V AC QJ2 QJH2 QJ2H HQJ2H 010,000 022,000 042,000 100,000 Type HQJ2H 100 110 125 150 175 200 225 7'' 3'' 2-pole QJ2 Internal Accessories (Factory installed only) (3-pole only) Add suffix to catalog number and adder to list price. 4.5'' 3-pole Auxiliary Switches Control Voltage Shunt Trip AC Suffix DC Suffix Shunt Trip and 1A and 1B Auxiliary Switch 2A and 2B List Adder $ Suffix List Adder $ Suffix List Adder $ 00S01■ 325. A01■ 265. A02■ 532. 01S01■ 590. 24 00S07■ 325. A01■ 265. A02■ 532. 01S07■ 590. 125 00S11■ 325. A01■ 265. A02■ 532. 01S11■ 590. 120/240 ■ Built to order. Allow 2–3 weeks for delivery. ▲ Built to order. Allow 6–8 weeks for delivery. See Note: A page 6-73. Note: QJ breakers are UL Listed for reverse feed applications. 6-28 1A and 1B List Adder $ 2.5 D 3'' MOLDED CASE CIRCUIT BREAKERS 6 060 070 080 090 100 110 125 150 175 200 225 Load side TA1Q300 lugs are mounted and included when circuit breaker is ordered. For line and load lugs (TA1Q300) installed at no additional charge, add suffix “L” to catalog number. HACR rated. accessories are not available on 2-pole QJ breakers. Internal Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Enclosures Section 5 Accessories pages 6-86 to 6-91 Discount Schedule MCCB Molded Case Circuit Breakers CQD 100A Frame Selection/Dimensions Type CQD (Cable In - Cable Out) DIN Rail Mount Shipping Weights 1-Pole 2-Pole Continuous Current Rating @ 40°C 277V AC 125V DC 480Y/277V AC 125/250V DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 115 120 125 130 CQD115 CQD120 CQD125 CQD130 140.00 140.00 140.00 140.00 CQD215 CQD220 CQD225 CQD230 305.00 305.00 305.00 305.00 CQD315 CQD320 CQD325 CQD330 543.00 543.00 543.00 543.00 135 140 145 150 160 CQD135■ CQD140■ CQD145■ CQD150■ CQD160■ CQD170■ CQD180■ CQD190■ CQD1100■ 140.00 140.00 140.00 140.00 140.00 CQD235■ CQD240 CQD245■ CQD250 CQD260 305.00 305.00 305.00 305.00 305.00 CQD335 CQD340 CQD345■ CQD350 CQD360 543.00 543.00 543.00 543.00 543.00 256.00 256.00 256.00 256.00 CQD270 CQD280 CQD290■ CQD2100 606.00 606.00 606.00 606.00 CQD370 CQD380 CQD390 CQD3100 735.00 735.00 735.00 735.00 170 180 190 100 3-Pole 480Y/277V AC Number of Poles Number per Carton Shipping Weight lbs. (kg) 1 2 3 1 1 1 0.5 (0) 1.0 (0) 1.5 (1) Lugs For 60/75°C Wire Amps Wire Size 15–40 #14–#6 AWG Cu #12–#6 AWG Al 45–100 #8–#1 AWG Cu #6–#1/0 AWG Al Type CQD6 (Cable In - Cable Out) CSA Certified, not UL Continuous Current Rating @ 40°C 600Y/347V AC 125/250V DC 3-Pole 600Y/347V AC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ — CQD6120 ■ CQD6125 ■ CQD6130 ■ CQD6135■ CQD6140■ CQD6145■ CQD6150■ CQD6160■ CQD6170■ — 140.00 140.00 140.00 140.00 140.00 140.00 140.00 140.00 CQD6215■ CQD6220■ CQD6225■ CQD6230■ CQD6235■ CQD6240■ CQD6245■ CQD6250■ CQD6260■ CQD6270■ 305.00 305.00 305.00 305.00 305.00 305.00 305.00 305.00 305.00 CQD6315■ CQD6320■ CQD6325■ CQD6330■ CQD6335■ CQD6340■ CQD6345■ CQD6350■ CQD6360■ — 543.00 543.00 543.00 543.00 543.00 543.00 543.00 543.00 543.00 256.00 606.00 CQD, CQD6 4.9 — MOLDED CASE CIRCUIT BREAKERS 170 2-Pole 347V AC 125V DC Interrupting Ratings RMS Symmetrical Amperes (KA) Breaker Type Number of Poles CQD (UL) CQD6 (CSA) Volts AC (50/60 Hz) CQD, CQD6 Volts DC 120 240 277 480/277 600/347 125 125/250 1 2 3 65 — — — 65 65 14 — — — 14 14 — — — 14 — — — 14 — 1 2 3 65 — — — 65 65 14 — — — — — 10 10 10 14 — — — 14 — For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. SWD rated. Note: CQD breakers are UL Listed for reverse feed applications. Discount Schedule MCCB HID rated. rated. HACR Enclosures Section 5 Accessories pages 6-31 and 6-86 to 6-91 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6 115 120 125 130 135 140 145 150 160 1-Pole 6-29 Molded Case Circuit Breakers NGG 125A Frame Selection/Dimensions Type NGG (Cable In - Cable Out) 1-Pole Continuous Ampere Rating @ 40°C 2-Pole Catalog Number List Price $ 15 20 25 30 NGG1B015L NGG1B020L NGG1B025L NGG1B030L 35 40 45 50 60 3-Pole Catalog Number List Price $ Catalog Number List Price $ 161.00 161.00 161.00 161.00 NGG2B015L NGG2B020L NGG2B025L NGG2B030L 504.00 504.00 504.00 504.00 NGG3B015L NGG3B020L NGG3B025L NGG3B030L 660.00 660.00 660.00 660.00 NGG1B035L NGG1B040L NGG1B045L NGG1B050L NGG1B060L 161.00 161.00 161.00 161.00 161.00 NGG2B035L NGG2B040L NGG2B045L NGG2B050L NGG2B060L 504.00 504.00 504.00 504.00 504.00 NGG3B035L NGG3B040L NGG3B045L NGG3B050L NGG3B060L 660.00 660.00 660.00 660.00 660.00 70 80 90 100 NGG1B070L NGG1B080L NGG1B090L NGG1B100L 271.00 271.00 271.00 271.00 NGG2B070L NGG2B080L NGG2B090L NGG2B100L 669.00 669.00 669.00 669.00 NGG3B070L NGG3B080L NGG3B090L NGG3B100L 777.00 777.00 777.00 777.00 110 125 NGG1B110L NGG1B125L 547.00 547.00 NGG2B110L NGG2B125L 1339.00 1339.00 NGG3B110L NGG3B125L 1544.00 1544.00 NGG 2.9 5.4 Line and load lugs are included as standard. If no lugs are required, remove the “L” suffix. HACR rated. Suitable for screws or DIN rail mounting. MOLDED CASE CIRCUIT BREAKERS 6 Shipping Weights NGG Number of Poles Number per Carton Shipping Weight lbs. (kg) 1 2 3 1 1 1 .75 (0.34) 1.3 (0.59) 2.0 (0.98) Lugs For 60/75°C Wire NGG Ampere Rating Wire Size Catalog Number 15–30A #14–#6 AWG Cu #12–#6 AWG Al TC1Q1 (qty. 1) 3TC1Q1 (qty. 3) List Price $ 35–125A #8–#1/0 AWG Cu #4–#2/0 AWG Al 3TC1GG20 (qty. 3) 13.40 15–125A Nut Keeper plate w/ screw (for crimp terminals) TNKG3 (qty. 3) 17.90 2.60 7.20 Interrupting Ratings Breaker Type NGG Number of Poles 01 2, 3 UL 489 AIR RMS Symmetrical Amperes (KA) Volts AC(50/60Hz) 120 240 277 347 65 — 25 14 0— 65 — — 480 — 25 Volts DC 600/347 125 125/250 0— 14 — 14 0— 14 IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu 25 12.5 — 65 33 25 lcs — 12.5 Volts DC 125/250 — 14 For inches / millimeters conversion, see Application Data section. SWD rated. rated at 15-50A 1-pole @ 277 VAC; 2 & 3-pole @ 480 VAC 125/250V DC rating applies to 2-pole NGG only. HID 6-30 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Enclosures Section 5 Accessories pages 6-31 and 6-86 to 6-91 Discount Schedule MCCB Molded Case Circuit Breakers Accessories for CQD 100A Frame, NGG and NGB 125A Frame햲 Selection Shunt Trip Control Voltage V AC V DC CQD, CQD6, NGG, NGB Catalog Number List Price $ 120 240 277 480 600 — — — — — CQDST120 CQDST240▲ CQDST277▲ CQDST480▲ CQDST600 636.00 636.00 636.00 636.00 636.00 — — — — 012 024 048 125 CQDST12 CQDST24 CQDST48 CQDST125 636.00 636.00 636.00 636.00 Auxiliary Switch Maximum Voltage AC DC Number of Contacts 240 240 125 125 1A–1B 2A–2B CQD, CQD6, NGG, NGB Catalog Number List Price $ CQDA1 CQDA2 271.00 540.00 CQD with Accessory Installed Alarm Switch Maximum Voltage AC DC CQD, CQD6, NGG, NGB Catalog Number 240 125 CQDBA List Price $ 271.00 Shunt Trip and Auxiliary Switch Combinations Shunt Trip Voltage CQDST24AAS▲ 897.00 120 CQDST120AAS▲ 897.00 240 CQDST240AAS▲ 897.00 277 CQDST277AAS▲ 897.00 480 CQDST480AAS▲ 897.00 600 CQDST600AAS▲ 897.00 12 CQDST12DAS▲ 897.00 24 CQDST24DAS▲ 897.00 48 CQDST48DAS▲ 897.00 125 CQDST125DAS▲ 897.00 DC MOLDED CASE CIRCUIT BREAKERS List Price $ 24 AC 6 CQD, CQD6, NGG, NGB Catalog Number Alarm and Auxiliary Switch Combinations For Breaker Catalog Number List Price CQD, CQD6, NGG, NGB CQDA1BA▲ 540.00 ▲ Built to order. Allow 6–8 weeks for delivery. 햲 Adds 1-pole space for accessory. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-31 Molded Case Circuit Breakers EG 125A Frame Selection/Dimensions Type NEG (Cable In - Cable Out) 1-Pole Continuous Ampere Rating @ 40°C 2-Pole Catalog Number List Price $ 15 20 25 30 NEG1B015L NEG1B020L NEG1B025L NEG1B030L 35 40 45 50 60 3-Pole Catalog Number List Price $ 297.00 297.00 297.00 297.00 NEG2B015L NEG2B020L NEG2B025L NEG2B030L NEG1B035L NEG1B040L NEG1B045L NEG1B050L NEG1B060L 297.00 297.00 297.00 297.00 297.00 70 80 90 100 NEG1B070L NEG1B080L NEG1B090L NEG1B100L 110 125 NEG1B110L NEG1B125L 4-Pole Catalog Number List Price $ Catalog Number List Price $ 743.00 743.00 743.00 743.00 NEG3B015L NEG3B020L NEG3B025L NEG3B030L 930.00 930.00 930.00 930.00 NEG4B015L NEG4B020L NEG4B025L NEG4B030L 1210.00 1210.00 1210.00 1210.00 NEG2B035L NEG2B040L NEG2B045L NEG2B050L NEG2B060L 743.00 743.00 743.00 743.00 743.00 NEG3B035L NEG3B040L NEG3B045L NEG3B050L NEG3B060L 930.00 930.00 930.00 930.00 930.00 NEG4B035L NEG4B040L NEG4B045L NEG4B050L NEG4B060L 1210.00 1210.00 1210.00 1210.00 1210.00 338.00 338.00 338.00 338.00 NEG2B070L NEG2B080L NEG2B090L NEG2B100L 845.00 845.00 845.00 845.00 NEG3B070L NEG3B080L NEG3B090L NEG3B100L 1056.00 1056.00 1056.00 1056.00 NEG4B070L NEG4B080L NEG4B090L NEG4B100L 1376.00 1376.00 1376.00 1376.00 747.00 747.00 NEG2B110L NEG2B125L 1864.00 1864.00 NEG3B110L NEG3B125L 2330.00 2330.00 NEG4B110L NEG4B125L 3029.00 3029.00 HEG 3.0 5.5 Type HEG (Cable In - Cable Out) 1-Pole MOLDED CASE CIRCUIT BREAKERS 6 Continuous Ampere Rating @ 40°C 2-Pole Catalog Number List Price $ 15 20 25 30 HEG1B015L HEG1B020L HEG1B025L HEG1B030L 35 40 45 50 60 3-Pole Catalog Number List Price $ Catalog Number 414.00 414.00 414.00 414.00 HEG2B015L HEG2B020L HEG2B025L HEG2B030L 966.00 966.00 966.00 966.00 HEG3B015L HEG3B020L HEG3B025L HEG3B030L HEG1B035L HEG1B040L HEG1B045L HEG1B050L HEG1B060L 414.00 414.00 414.00 414.00 414.00 HEG2B035L HEG2B040L HEG2B045L HEG2B050L HEG2B060L 966.00 966.00 966.00 966.00 966.00 HEG1B070L HEG1B080L HEG1B090L HEG1B100L 492.00 492.00 492.00 492.00 HEG2B070L HEG2B080L HEG2B090L HEG2B100L 110 HEG1B110L 1031.00 125 HEG1B125L 1031.00 Line and load lugs are included as standard. HACR rated. Suitable for screw mounting. HEG2B110L HEG2B125L 70 80 90 100 4-Pole List Price $ Catalog Number List Price $ 1133.00 1133.00 1133.00 1133.00 HEG4B015L HEG4B020L HEG4B025L HEG4B030L 1474.00 1474.00 1474.00 1474.00 HEG3B035L HEG3B040L HEG3B045L HEG3B050L HEG3B060L 1133.00 1133.00 1133.00 1133.00 1133.00 HEG4B035L HEG4B040L HEG4B045L HEG4B050L HEG4B060L 1474.00 1474.00 1474.00 1474.00 1474.00 1098.00 1098.00 1098.00 1098.00 HEG3B070L HEG3B080L HEG3B090L HEG3B100L 1260.00 1260.00 1260.00 1260.00 HEG4B070L HEG4B080L HEG4B090L HEG4B100L 1638.00 1638.00 1638.00 1638.00 2136.00 2136.00 HEG3B110L HEG3B125L 2561.00 2561.00 HEG4B110L HEG4B125L 3330.00 3330.00 NEG, HEG Lugs For 60/75°C Wire Shipping Weights NEG/HEG Number of Poles Number per Carton Shipping Weight lbs. (kg) 1 2 3 4 1 1 1 1 1.1 2.0 3.1 3.9 (0.5) (0.9) (1.4) (1.8) Ampere Rating Wire Size Catalog Number List Price $ 15–125A #14 – 3/0 AWG Cu (steel lugs) 3TW1EG30 (qty. 3) 12.80 15–125A #14 – 1/0 AWG Cu #14 – 1/0 AWG Al 3TA1EG10 (qty. 3) 12.80 15–125A #6 - 3/0 AWG Cu #6 - 3/0 AWG AI 3TA1EG30 (qty. 3) 12.80 15–125A Nut Keeper plate w/ screw (for crimp terminals) TNKE3 (qty. 3) 12.30 Interrupting Ratings Breaker Type NEG HEG Number of Poles 01 2, 3, 4 01 2, 3, 4 UL 489 AIR RMS Symmetrical Amperes (KA) Volts AC(50/60Hz) 240 277 347 480 085 35 22 — 085 — — 35 0100 65 25 — 0100 — — 65 600/347 — 22 — 25 Volts DC 125 125/250 35 — — 35 42 — — 42 IEC 60947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu 85 43 — 85 43 40 100 50 — 100 50 70 lcs — 20 — 35 Volts DC 125 125/250 35 — — 35 42 — — 42 For inches / millimeters conversion, see Application Data section. SWD Applies HID Optional rated. rated 277 VAC. 6-32 to 3 & 4-pole breakers only. lugs for NEG and HEG breakers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Accessories pages 6-33 and 6-86 to 6-91 Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories for NEG and HEG 125A Frame Selection Shunt Trip Control Voltage V AC V DC NEG, HEG Catalog Number List Price $ 110-240 380-600 24-60 125 — 24-60 STRER240 STREV600 STREM60D 636.00 636.00 636.00 Auxiliary Switch Maximum Voltage AC DC Number of Contacts 240 240 125 125 1A–1B 2A–2B NEG, HEG Catalog Number List Price $ ASKE2 ASKE3 271.00 540.00 Alarm Switch Maximum Voltage AC DC Number of Contacts 240 240 125 125 1A–1B 2A–2B NEG, HEG Catalog Number List Price $ ASKE1 ASKE5 271.00 540.00 Undervoltage Trip Control Voltage UVREM60▲ 636.00 120 UVREN120 636.00 240 UVRER240 636.00 480 UVREU480▲ 636.00 600 UVREV600▲ 636.00 24 24 UVREB24AD 636.00 48 UVREC48D▲ 636.00 125 UVRED125D▲ 636.00 250 UVREE250D▲ 636.00 MOLDED CASE CIRCUIT BREAKERS List Price $ 60 DC 6 NEG, HEG Catalog Number AC Alarm and Auxiliary Switch Combinations For Breaker NEG, HEG Catalog Number ASKE6 List Price $ 540.00 ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-33 Molded Case Circuit Breakers ED 125A Frame Sentron Series Selection Ordering Instructions All ED Frame Sentron circuit breakers are supplied with load side lugs. If line side lugs are required, add ”L” suffix to catalog number. Consult Siemens sales office for any addditional charge 50°C Calibration, 400HZ - see page 6-84. All ED frame circuit breakers may be reverse connected Type ED2 Blue Label 1-Pole Continuous Current Rating @ 40° C 015 020 25 030 35 040 45 050 060 070 80 90 100 2-Pole 120V AC 125V DC 240V AC 125V DC 250V DC 240V AC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ ED21B015■ ED21B020■ ED21B025■ ED21B030■ ED21B035■ ED21B040■ ED21B045■ ED21B050■ ED21B060■ ED21B070■ ED21B080■ ED21B090■ ED21B100■ 125.00 125.00 125.00 125.00 125.00 125.00 125.00 125.00 125.00 ED22B015 ED22B020 ED22B025■ ED22B030 ED22B035■ ED22B040 ED22B045■ ED22B050 ED22B060 288.00 288.00 288.00 288.00 288.00 288.00 288.00 288.00 288.00 ED23B015 ED23B020 ED23B025■ ED23B030 ED23B035■ ED23B040 ED23B045■ ED23B050 ED23B060 428.00 428.00 428.00 428.00 428.00 428.00 428.00 428.00 428.00 230.00 230.00 230.00 230.00 ED22B070 ED22B070■ ED22B090■ ED22B100 470.00 470.00 470.00 470.00 ED23B070 ED23B080 ED23B090■ ED23B100 613.00 613.00 613.00 613.00 Type ED4 6 MOLDED CASE CIRCUIT BREAKERS 2-Pole 3-Pole Continuous Current Rating @ 40° C 120V AC 277V AC 125V DC 480V AC 250V DC 480V AC Catalog Number List Price $ Catalog Number List Price $ 015 020 025 030 035 040 045 050 060 ED41B015 ED41B020 ED41B025 ED41B030 ED41B035■ ED41B040 ED41B045■ ED41B050 ED41B060 170.00 170.00 170.00 170.00 170.00 170.00 170.00 170.00 170.00 ED42B015 ED42B020 ED42B025 ED42B030 ED42B035■ ED42B040 ED42B045■ ED42B050 ED42B060 521.00 521.00 521.00 521.00 521.00 521.00 521.00 521.00 521.00 ED43B015 ED43B020 ED43B025 ED43B030 ED43B035 ED43B040 ED43B045 ED43B050 ED43B060 684.00 684.00 684.00 684.00 684.00 684.00 684.00 684.00 684.00 070 080 090 100 ED41B070 ED41B080■ ED41B090■ ED41B100 289.00 289.00 289.00 289.00 ED42B070 ED42B080■ ED42B090■ ED42B100 686.00 686.00 686.00 686.00 ED43B070 ED43B080 ED43B090 ED43B100 804.00 804.00 804.00 804.00 110 125 — — — — ED42B110■ ED42B125 1386.00 1386.00 ED43B110 ED43B125 1594.00 1594.00 Catalog Number Type ED6 List Price $ Blue Label 1-Pole 2-Pole 3-Pole Continuous Current Rating @ 40° C 600V AC 250V DC 600V AC 500V DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 015 020 025 030 035 040 045 050 060 ED61B015 ED61B020 ED61B025 ED61B030 ED61B035 ED61B040 ED61B040■ ED61B050 ED61B060 349.00 349.00 349.00 349.00 349.00 349.00 349.00 349.00 349.00 613.00 613.00 613.00 613.00 613.00 613.00 613.00 613.00 613.00 ED63B015 ED63B020 ED63B025 ED63B030 ED63B035 ED63B040 ED63B045 ED63B050 ED63B060 778.00 778.00 778.00 778.00 778.00 778.00 778.00 778.00 778.00 070 080 090 100 ED61B070■ ED61B080 ED61B090 ED61B100■ — — 480.00 480.00 480.00 480.00 ED62B015 ED62B020 ED62B025■ ED62B030 ED62B035■ ED62B040■ ED62B045■ ED62B050■ ED62B060■ ED62B070■ ED62B080■ ED62B090■ ED62B100■ — — 773.00 773.00 773.00 773.00 ED63B070 ED63B080 ED63B090 ED63B100 973.00 973.00 973.00 973.00 — — ED63B110 ED63B125 1872.00 1872.00 110 125 347V AC — — Note: ED frame circuit breakers qualified to UL 489 Supplement SB “Naval”— See page 6-84 for additional information ■ Built to order. Allow 2–3 weeks for delivery. 6-34 Number per Carton Shipping Weight (lbs.) ED2, ED4, ED6, HED4, HHED6 Blue Label 1-Pole Shipping Weights Number of Poles 3-Pole 1 2 3 30 10 10 38 25 38 5 5 20 30 CED6 2 3 Lugs Ampere Rating No. of Poles Catalog Number Wire Range Aluminum Body Lugs All 15–25A 1, 2, 3 All 30–100A 1, 2, 3 ED2, 4, CED6 1 30–60A ED2, 4, CED6 1 70–100A ED2, 4, 6, HED4, HHED6 2, 3 30–100A All 110, 125A 2, 3 Line/Load SA1E025 Line Side LN1E100 Load Side LD1E060 Load Side LD1E100 #14–#10 Cu #12–#10 Al Load Side LN1E100 #10–1/0 Cu/Al Line/Load TA1E6125 #3–3/0 Cu #1–2/0 Al Line/Load TC1ED6150 #10–1/0 Cu only CCE125 2/0 #10–1/0 Cu/Al #10–#4 Cu/Al #6–#1/0 Cu/Al Copper Body Lugs All 30–125A 1, 2, 3 Compression Lugs All ED, HHED, CED Enclosures (Neutral Included) Type 1 (Surface) 1 (Flush) 3R 4–4X 7–9 7–9 12 1 (Surface) 1 (Flush) 3R 12 Catalog Number E2N1S (15–100A) E2N1F (15–100A) E2N3R (15–100A) ED6SS4 (15–100A) EA (15–60A) EB (70–100A) E2N12 (15–100A) CED6N1S CED6N1F CED6N3R CED6N12 List Price $ 149.00 149.00 410.00 2841.00 1750.00 2176.00 254.00 271.00 271.00 725.00 449.00 Modifications page 6-84 Enclosures Section 5 Accessories pages 6-36 and 6-86 to 6-91 CSA Certified only (Not UL) CED types and all 110–125 ampere ED frames. Note: A, page 6-81. SWD rated. HACR rated. For See Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers ED 125A Frame Sentron Series Selection/Dimensions Type HED4 Black Label 2-Pole FIGURE1 - ED, HED, HHED 3-Pole 1-Pole 480V AC List Price $ Catalog Number List Price $ HED41B015 HED41B020 HED41B025 HED41B030 HED41B035■ HED41B040 HED41B045■ HED41B050■ HED41B060■ HED41B070■ HED41B080■ HED41B090■ HED41B100■ — — 397.00 397.00 397.00 397.00 397.00 397.00 397.00 397.00 397.00 HED42B015 HED42B020 HED42B025■ HED42B030 HED42B035■ HED42B040 HED42B045■ HED42B050 HED42B060■ HED42B070■ HED42B080■ HED42B090■ HED42B100■ HED42B110■ HED42B125■ 929.00 929.00 929.00 929.00 929.00 929.00 929.00 929.00 929.00 HED43B015 HED43B020 HED43B025 HED43B030 HED43B035 HED43B040 HED43B045 HED43B050 HED43B060 1140.00 1140.00 1140.00 1140.00 1140.00 1140.00 1140.00 1140.00 1140.00 1070.00 1070.00 1070.00 1070.00 HED43B070 HED43B080 HED43B090 HED43B100 1227.00 1227.00 1227.00 1227.00 2176.00 2176.00 HED43B110 HED43B125 2510.00 2510.00 — — W1 W3 W2 1-POLE 2-POLE 3-POLE FIGURE 2 - CED (3-Pole shown) D 2-Pole 600V AC, 250V DC Catalog List Number Price $ CED62B015 2756.00 CED62B020■ 2756.00 — — CED62B030■ 2756.00 — — CED62B040■ 2756.00 — —— CED62B050■ 2756.00 CED62B060■ 2756.00 CED62B070■ 2756.00 CED62B080■ 2756.00 CED62B090■ 2756.00 CED62B100■ 2756.00 — — CED62B125■ 4135.00 D1 H 3-Pole 600V AC, 500V DC Catalog List Number Price $ CED63B015 3200.00 CED63B020 3200.00 — —— CED63B030 3200.00 — —— CED63B040 3200.00 — —— CED63B050 3200.00 CED63B060 3200.00 CED63B070 3200.00 CED63B080 3200.00 CED63B090 3200.00 CED63B100 3200.00 CED63B110■ 4885.00 CED63B125 4885.00 W2, W3 Dimensions (in inches) Breaker Type W1 W2 W3 H D D1 Figure 1 ED2, ED4, ED6, HED4, ED6 ETI 1 2 3 6.35 3.92 4.56 Figure 1 HHED6 — 2 3 6.53 3.92 4.56 Figure 2 CED6, CED6 ETI — 2 3 9.58 3.92 4.56 Interrupting Ratings Breaker Type ED2 (1-P) ED2 (2, 3-P) ED4 (1-P) ED4 (2, 3-P) ED6 (1P) ED6 (2, 3-P) HED4 (1-P) (15–30A) HED4 (1-P) (35–100A) HED4 (2, 3-P) HHED6 (2, 3-P) CED6 (2, 3-P) UL 489 AIR (File #E10848) RMS Symmetrical Amperes (KA) Volts AC 120 240 277 347 480 010 — — — — — 010 — — — 065 — 22 — — — 065 — — 18 — — — — 30 — 065 — — 25 600 — — — — — 18 Volts DC 125 250 05 — — 05 (2-P) 30 — — 30 (2-P) — — — 500 — — — — — 18 (3-P) IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu lcs — — — — — — — — — — — — — — — — — — — — 65 17 35 9 500 lcu — — — — — 18 lcs — — — — — 5 100 — 65 — — — 30 — — — — — — — — 100 — 100 100 200 25 — — 30 — — 018 100 — — — 30 (2-P) — 50 (2-P) — — — — 42 0 65 200 — — — — — — — — — — — — — — — — — — — — — — — — — — ■ Built to order. Allow 2–3 weeks for delivery. SWD rated. When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. Discount Schedule MCCB HED4 — 50 (3-P) and HHED6 type circuit breakers meet the UL criteria for “current limiting” at 240V AC. ED6-ETI, CED6-ETI, see page 6-66 for ordering information. Single Pole 15-30A 30KA @ 347V non-UL. 35-100A 18KA @ 347V non-UL. HACR rated. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-35 MOLDED CASE CIRCUIT BREAKERS List Price $ 1183.00 1183.00 1183.00 1183.00 1183.00 1183.00 1183.00 1183.00 1183.00 1344.00 1344.00 1344.00 1344.00 2633.00 2633.00 6 List Price $ 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1010.00 1174.00 1174.00 1174.00 1174.00 2262.00 2262.00 3-Pole 600V AC Catalog Number HHED63B015 HHED63B020 HHED63B025 HHED63B030 HHED63B035 HHED63B040 HHED63B045 HHED63B050 HHED63B060 HHED63B070 HHED63B080 HHED63B090 HHED63B100 HHED63B110 HHED63B125 Fuseless Current Limiting Type CED6 Red Label Black Label 2-Pole 600V AC Catalog Number HHED62B015■ HHED62B020■ HHED62B025■ HHED62B030■ HHED62B035■ HHED62B040■ HHED62B045■ HHED62B050■ HHED62B060■ HHED62B070■ HHED62B080■ HHED62B090■ HHED62B100■ HHED62B110■ HHED62B125■ D1 H 449.00 449.00 449.00 449.00 D Type HHED6 Continuous Current Rating @ 40°C 015 020 025 030 035 040 045 050 060 070 080 090 100 110 125 250V DC Catalog Number 110 125 480V AC List Price $ 070 080 090 100 125V DC Catalog Number 015 020 025 030 035 040 045 050 060 277V AC Continuous Current Rating @ 40° C Molded Case Circuit Breakers Accessories Accessories for: ED 125A Frame Selection Shunt Trip Combinations 1 Shunt Trip AC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number S17ED60 S18ED60 S01ED60 — S03ED60 S15ED60▲ S04ED60 — — S01ED62A S02ED62A▲ S03ED62A S15ED64A▲ S04ED64A▲ — — S01ED62AB S02ED62AB▲ S03ED62AB S15ED64AB▲ S04ED64AB▲ — — S01ED62B S02ED62B▲ S03ED62B▲ S15ED64B▲ S04ED64B▲ — — S01ED62AA S02ED62AA▲ S03ED62AA▲ — — S16ED60▲ S07ED60 S09ED60▲ S11ED60▲ S13ED60▲ S16ED62A▲ S07ED62A S09ED62A▲ S11ED62A▲ S13ED62A▲ — S07ED62AB▲ S09ED62AB▲ S11ED62AB▲ S13ED62AB▲ — S07ED62B▲ S09ED62B▲ S11ED62B▲ S13ED62B▲ — S07ED62AA▲ S09ED62AA▲ S11ED62AA▲ S13ED62AA▲ 897.00 1157.00 897.00 1157.00 DC 024 048 120 208 240 277 480 Combinations Available only when ordered together. Only one module can be added to a breaker. Additional accessories, which always attach to the left pole, cannot be added to the combination later. Adds 1 inch pole space. MOLDED CASE CIRCUIT BREAKERS 6 Equipment Ground Sensing A field addable kit containing 30mA or 5 mA ground fault accessory module, current transformer with 24 inch leads, and current transformer mounting equipment. Current transformer to mount in gutter of lighting panel or any control panel. Accessory module operates from separate 120V control power source. Both 30MA and 5MA devices are equipment protection devices only. Do not use for personnel protection. 1 Shunt Trip 1 Shunt Trip and 1 Auxiliary Switch 1 Auxiliary Switch and 1 Alarm Switch Control Voltage 012 024 048 125 250 List Price $: 636.00 1 Shunt Trip and 1 Alarm Switch 1 Shunt Trip and 2 Auxiliary Switches Undervoltage Trip Combinations Control Voltage AC 1 Undervoltage Trip DC 120 208 240 277 480 600 024 048 125 250 1 Undervoltage Trip 1 Undervoltage and 1 Auxiliary 1 Undervoltage Trip and Switch and Trip and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number U01ED60 U02ED60▲ U03ED60 U16ED60▲ U06ED60▲ U08ED60▲ U01ED62A U02ED62A▲ U03ED62A▲ U16ED64A▲ U06ED64A▲ — U01ED62AB▲ U02ED62AB▲ U03ED62AB▲ U16ED64AB▲ U06ED64AB▲ — U01ED62B▲ U02ED62B▲ U03ED62B▲ U16ED64B▲ U06ED64B▲ — U01ED62AA▲ U02ED62AA▲ U03ED62AA▲ — — — U13ED60 U14ED60▲ U10ED60▲ U12ED60▲ U13ED62A▲ U14ED62A▲ U10ED62A▲ U12ED62A▲ U13ED62AB▲ U14ED62AB▲ U10ED62AB▲ — U13ED62B▲ U14ED62B▲ U10ED62B▲ — U13ED62AA▲ U14ED62AA▲ U10ED62AA▲ U12ED62AA▲ 897.00 1157.00 897.00 1157.00 List Price $: 636.00 Auxiliary Switch Combinations Maximum Voltage 1 Auxiliary Switch 1 Alarm Switch and 1 Auxiliary Switch AC DC Catalog Number Catalog Number Catalog Number Catalog Number 240 250 A01ED62 A01ED62B A02ED62 A02ED62B 2 Auxiliary Switches 1 Alarm Switch and 2 Auxiliary Switches 480 A01ED64 A01ED64B — — List Price $: 271.00 540.00 540.00 802.00 Maximum Voltage 1 Auxiliary Switch AC Catalog Number List Price $ A01EDLV 342.00 DC 12 Gold Plated Contacts—for PLC use Alarm Switch Only Maximum Voltage 1 Alarm Switch AC DC Catalog Number List Price $ 240 250 B00ED62 271.00 B00ED64 271.00 480 Ground Fault Sensing Relay Kit — Equipment Protection Only For Use With Breaker Frame CED6, ED2, ED4 ED6, EFC, EFF, HED4, HHED6 Number of Poles Description 1, 2, 3 Catalog Number 30mA 5mA List Price $ Basic Kit GF01ED60 GF01ED65 1483.00 Basic Kit with Normally Open Bell Alarm GF01ED60B0 GF01ED65B0▲ 1734.00 Basic Kit with Normally Closed Bell Alarm GF01ED60BC GF01ED65BC▲ 1734.00 ▲ Built to order. Allow 6–8 weeks for delivery. 6-36 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Accessories Selection Type FXD6-A Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker – Without Lugs) 2-Pole Catalog Number FXD62B070■ FXD62B080■ FXD62B090■ FXD62B100 FXD62B110■ FXD62B125 FXD62B150 FXD62B175 FXD62B200 FXD62B225 FXD62B250 Continuous Current Rating @ 40°C 70 80 90 100 110 125 150 175 200 225 250 3-Pole Catalog Number FXD63B070 FXD63B080 FXD63B090 FXD63B100 FXD63B110 FXD63B125 FXD63B150 FXD63B175 FXD63B200 FXD63B225 FXD63B250 List Price $ 1801.00 1801.00 1801.00 1801.00 1801.00 1801.00 1801.00 1801.00 1801.00 1801.00 3062.00 Type FD6-A List Price $ 2276.00 2276.00 2276.00 2276.00 2276.00 2276.00 2276.00 2276.00 2276.00 2276.00 3572.00 Blue Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Catalog List Number Price $ Frame Only Catalog Number Trip Unit Only Catalog List Number Price $ List Price $ 2-Pole 600V AC, 250V DC 70 80 90 100 110 125 150 175 200 225 250 FD62B070■ FD62B080■ FD62B090■ FD62B100■ FD62B110■ FD62B125■ FD62B150 FD62B175■ FD62B200 FD62B225■ FD62B250■ 1896.00 1896.00 1896.00 1896.00 1896.00 1896.00 1896.00 1896.00 1896.00 1896.00 3158.00 FD62F250 869.00 FD63T070■ FD63T080■ FD63T090■ FD63T100 FD63T110■ FD63T125 FD63T150 FD63T175 FD63T200 FD63T225 FD63T250 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 2456.00 3-Pole 600V AC, 500V DC 70 80 90 100 110 125 150 175 200 225 250 FD63B070■ FD63B080■ FD63B090■ FD63B100 FD63B110■ FD63B125 FD63B150 FD63B175 FD63B200 FD63B225 FD63B250 2414.00 2414.00 2414.00 2414.00 2414.00 2414.00 2414.00 2414.00 2414.00 2414.00 3713.00 FD63F250 1125.00 Breaker Type FXD6-A, FD6-A HFXD6 , HFD6 HHFD6 , HHFXD6 CFD6 65 100 200 200 35 65 100 200 22 25 25 100 30 (2-P) 30 (2-P) — 50 (2-P) 18 (3-P) 25 (3-P) — 50 (3-P) IEC 947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu lcs 65 33 35 9 100 50 65 33 200 100 100 50 — — — — 500 lcu 20 42 65 — 170-90 100-110 125-150 175-200 225-250 600 700 800 900 1100 640 770 900 1060 1300 690 840 1000 1210 1500 Wire Range List Price $ #6—350 kcmil Cu #4—350 kcmil Al TC1FD350 #6—350 kcmil Cu Compression Lug CCF250 350 kcmil Cu/Al 22.00 34.50 51.00 Enclosures Type Catalog Number List Price $ 1 3R 4-4X 7-9 12 Neutral F6N1S(F) F6N3R FD6SS4 EC2 F6N12 N250 184.00 606.00 4720.00 4815.00 410.00 143.00 lcs 10 21 33 — Instantaneous Adjustment Trip Range Nominal Instantaneous Values +20% Breaker Ampere Tolerance Rating Low 2 3 Catalog Number TA1FD350A Interrupting Ratings RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC (50/60Hz) Volts DC 240 480 600 250 500 Lugs For 75°C Wire Modifications page 6-84 Enclosures Section 5 Accessories pages 6-39 and 6-86 to 6-91 4 5 6 7 730 920 1100 1370 1700 770 990 1200 1520 1900 810 1060 1300 1780 2100 850 1140 1400 1930 2300 +20% Tolerance High 900 1200 1500 2000 2500 ■ Built to order. Allow 2–3 weeks for delivery. Type FXD6-A circuit breakers are UL Listed for reverse fed applications. units are 3-pole width. When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. Order neutral as separate item. See Note: A, page 6-81. HFD6 and HHFD6 type circuit breakers meet the UL criteria for “current limiting” at 240 and 480V AC. HACR rated. 2-pole Note: FD frame qualified to UL489 supplement SB “NAVAL”. See page 6-84 for additional information. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-37 MOLDED CASE CIRCUIT BREAKERS 939.00 939.00 939.00 939.00 939.00 939.00 939.00 939.00 939.00 939.00 2201.00 Complete Breaker Unassembled with Lugs Prices of FD6, HFD6, and HHFD6 breakers includes frame, trip and both line and load lugs (TA1FD350A). When ordered by these catalog numbers, the customer will receive the frame, trip, and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of FXD6, HFXD6, HHFXD6, and CFD6 includes frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA1FD350A) installed, add suffix “L” to catalog number (add 2 times list price of lugs for each pole). 50°C Applications see page 6-84. 400 Hz Applications see page 6-84. 6 FD62T070■ FD62T080■ FD62T090■ FD62T100■ FD62T110■ FD62T125■ FD62T150 FD62T175■ FD62T200 FD62T225■ FD62T250■ Ordering Information Molded Case Circuit Breakers FD 250A Frame Sentron Series Selection/Dimensions Type HFD6, Type HFXD6 Black Label Interchangeable Trip Frame Only Catalog Number Catalog Number List Price $ Trip Unit Only List Price $ Catalog Number D1 Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs List Price $ L 2-Pole 600V AC, 250V DC (3-Pole Width) FD63T070■ FD63T080■ FD63T090■ FD63T100 FD63T110■ FD63T125 FD63T150 FD63T175 FD63T200 FD63T225 FD63T250 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 2456.00 HFD63B070■ HFD63B080■ HFD63B090■ HFD63B100 HFD63B110■ HFD63B125 HFD63B150 HFD63B175 HFD63B200 HFD63B225 HFD63B250 5053.00 5053.00 5053.00 5053.00 5053.00 5053.00 5053.00 5053.00 5053.00 5053.00 6352.00 HFD63F250 3764.00 Type HHFD, HHFXD6 6 HHFD63B070■ HHFD63B080■ HHFD63B090■ HHFD63B100 HHFD63B110■ HHFD63B125 HHFD63B150 HHFD63B175 HHFD63B200 HHFD63B225 HHFD63B250 MOLDED CASE CIRCUIT BREAKERS 5866.00 5866.00 5866.00 5866.00 5866.00 5866.00 5866.00 5866.00 5866.00 5866.00 7165.00 Figure 1 Breaker Type Figure 1 FXD6-A, FD6-A, HFD6, HFXD6, HHFD6, FD6-ETI Figure 2 CFD6, CFD6-ETI W Figure 2 W L D D1 (to handle) 4.50 09.50 4 5.25 4.50 14.25 4 5.25 Shipping Weights 3-Pole 600V AC, Extra High Interrupting 070 080 090 100 110 125 150 175 200 225 250 W Dimensions (in inches) 3-Pole 600V AC, 500V DC 070 080 090 100 110 125 150 175 200 225 250 L 3129.00 939.00 939.00 939.00 939.00 939.00 939.00 939.00 939.00 939.00 939.00 2201.00 D HFD62F250 FD62T070■ FD62T080■ FD62T090■ FD62T100■ FD62T110■ FD62T125■ FD62T150■ FD62T175■ FD62T200■ FD62T225■ FD62T250■ 4156.00 4156.00 4156.00 4156.00 4156.00 4156.00 4156.00 4156.00 4156.00 4156.00 5418.00 D HFD62B070■ HFD62B080■ HFD62B090■ HFD62B100■ HFD62B110■ HFD62B125■ HFD62B150■ HFD62B175■ HFD62B200■ HFD62B225■ HFD62B250■ 070 080 090 100 110 125 150 175 200 225 250 HHFD63F250 4577.00 Type CFD6 FD63T070■ FD63T080■ FD63T090■ FD63T100 FD63T110■ FD63T125 FD63T150 FD63T175 FD63T200 FD63T225 FD63T250 Number of Number per Shipping Poles Carton Weight (lbs.) FD6-A, HFD6, HHFD6, FXD6-A Assembled Circuit Breaker (less connectors) 2 1 08.6 3 1 10 FD6-A, HFD6, HHFD6 Frame Only 2 1 07.5 3 1 08.7 FD6 Trip Unit Only 2 1 01.1 3 1 01.3 CFD6 Assembled Circuit Breaker (less terminals) 2 1 31 3 1 34 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 1157.00 2456.00 Red Label Fuseless Current Limiting Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) 3-Pole Continuous Current Rating @ 40°C 600V AC/500V DC Catalog Number List Price $ 070 080 090 100 110 125 150 175 200 225 250 CFD63B070■ CFD63B080■ CFD63B090■ CFD63B100■ CFD63B110■ CFD63B125■ CFD63B150 CFD63B175 CFD63B200 CFD63B225 CFD63B250 6346.00 6346.00 6346.00 6346.00 6346.00 6346.00 6346.00 6346.00 6346.00 6346.00 7052.00 ■ Built to order. Allow 2–3 weeks for delivery. When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. For non-interchangeable trip 3-pole HFD6 type circuit 6-38 breaker, change prefix identifier from HFD6 to HFXD6. Price equals frame and trip prices combined, e.g. price of HFXD63B250 equals price of HFD63F250 plus price of FD63T250. Order lugs separately. Type HFXD6, HHFXD6, CFD6 are UL Listed for reverse feed applications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Type HFXD6, HFD6, HHFD6, HHFXD6 meet the UL criteria for “Current Limiting” at 240 VAC and 480V AC. FXD6, ETI, CFD6, ETI — See page 6-66 for ordering information. HACR rated. Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories Accessories: for FD, FFC & FFF 250A Frames Selection Shunt Trip Combinations Control Voltage 1 Shunt Trip AC Catalog Number List Price $ S17FD60 S01FD60 S03FD60 S15FD60▲ S04FD60 S06FD60▲ 636.00 636.00 636.00 636.00 636.00 636.00 S16FD60▲ S07FD60 S09FD60▲ S11FD60 S13FD60▲ 636.00 636.00 636.00 636.00 636.00 DC 024 120 240 277 480 600 012 024 048 125 250 Undervoltage Trip Combinations 1 Undervoltage Trip and 1 Auxiliary Switch 햲 Control Voltage 1 Undervoltage Trip AC Catalog Number List Price $ Catalog Number List Price $ U01FD60 U02FD60▲ U03FD60 U16FD60▲ U06FD60▲ U08FD60▲ 636.00 636.00 636.00 636.00 636.00 636.00 W01FD64 W02FD64▲ W03FD64▲ W16FD64▲ W06FD64▲ — 897.00 897.00 897.00 897.00 897.00 — U13FD60 U14FD60▲ U10FD60▲ U12FD60▲ 636.00 636.00 636.00 636.00 W13FD64 W14FD64▲ W10FD64▲ W12FD64▲ 897.00 897.00 897.00 897.00 DC 120 208 240 277 480 600 024 048 125 250 Auxiliary Switch Combinations 6 1 Auxiliary Switch Voltage 2 Auxiliary Switches Catalog Number List Price $ 240 A01FD62 271.00 A02FD62 540.00 480 A01FD64 271.00 A02FD64 540.00 A01FDLV 342.00 Gold Plated Contacts - for PLC use AC DC 12 MOLDED CASE CIRCUIT BREAKERS Catalog Number List Price $ Alarm Switch Combinations Maximum Voltage 1 Alarm Switch 1 Alarm Switch and 1 Auxiliary Switch AC DC Catalog Number List Price $ Catalog Number List Price $ 480 250 B00FD64 271.00 C01FD64 540.00 ▲ Built to order. Allow 6–8 weeks for delivery. 햲 Auxiliary switch application is for 480V AC maximum. Note: Old F-frame accessories cannot be used in new Sentron line. Likewise, new FD-frame accessories cannot be used on old F-frame circuit breakers. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-39 Molded Case Circuit Breakers JD 400A Frame Sentron Series Type Selection JXD2-A Blue Label 240V AC , 2-Pole 250V DC Only Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) 2-Pole (3-Pole Width) Catalog List Number Price $ JXD22B200■ 2546.00 JXD22B225■ 2546.00 JXD22B250■ 2546.00 JXD22B300 2546.00 JXD22B350■ 2546.00 JXD22B400 2546.00 Continuous Current Rating @ 40°C 200 225 250 300 350 400 3-Pole List Price $ 3094.00 3094.00 3094.00 3094.00 3094.00 3094.00 Catalog Number JXD23B200 JXD23B225 JXD23B250 JXD23B300 JXD23B350 JXD23B400 Type JXD6-A Blue 600V AC , 2-Pole 250V DC, 3-Pole 500V DC Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) JXD62B200■ JXD62B225■ JXD62B250■ JXD62B300 JXD62B350■ JXD62B400 200 225 250 300 350 400 3184.00 3184.00 3184.00 3184.00 3184.00 3184.00 JXD63B200 JXD63B225 JXD63B250 JXD63B300 JXD63B350 JXD63B400 Type JD6-A Label 3764.00 3764.00 3764.00 3764.00 3764.00 3764.00 Blue Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Catalog List Number Price $ Frame Only Catalog Number Trip Unit Only Catalog List Number Price $ List Price $ MOLDED CASE CIRCUIT BREAKERS 6 2-Pole 600V AC, 250V DC (3-Pole Width) JD62B200■ JD62B225■ JD62B250■ JD62B300■ JD62B350■ JD62B400 200 225 250 300 350 400 3309.00 3309.00 3309.00 3309.00 3309.00 3309.00 JD62F400 1324.00 JD62T200■ JD62T225■ JD62T250■ JD62T300■ JD62T350■ JD62T400 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 1694.00 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 3-Pole 600V AC, 500V DC 200 225 250 300 350 400 JD63B200 JD63B225 JD63B250 JD63B300 JD63B350 JD63B400 3953.00 3953.00 3953.00 3953.00 3953.00 3953.00 JD63F400 Interrupting Ratings Breaker Type JXD2-A JXD6-A, JD6-A HJD6-A, HJXD6-A HHJD6, HHJXD6 CJD6-A RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC Volts DC (50/60Hz) 240 065 065 100 200 200 480 — 035 065 100 150 600 — 025 035 050 100 250 30 (2-P) 30 (2-P) 30 (2-P) — 50 (2-P) 500 — 25 (3-P) 35 (3-P) — 50 (3-P) Volts AC (50/60Hz) 220/240 380/415 500 lcu — 065 100 200 — lcu — 30 42 65 — lcs — 033 050 100 — lcu — 040 065 100 — Complete Breaker Unassembled with Lugs Prices of JD6, HJD6, and HHJD6 breakers include frame, trip and both line and load lugs (TA2J6500). When ordered by these catalog numbers, the customer will receive the frame, trip, and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of JXD6, HJXD6, HHJXD6, and CJD6 include frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA2J6500) installed, add suffix “L” to catalog number (add 2 times list price of lugs for each pole). 100% Rated Types JXD6 and HJXD6 breakers are available with 100% ratings. To order add suffix “H” to catalog number, and 10% to list price.■ 100% rated JD breakers require the use of 90° C Cu cable sized at 75° C ampacity and lugs TC1J6600 or TC2J6500. 50° C Applications see page 6-84. 400Hz Applications see page 6-84. Lugs For 75°C Wire Cables per Lug 1, 2 2 TA1L6750 1 1 TC1J6600 1 TC2J6500 1, 2 Compression Lug CCL600 1 Catalog Number TA2J6500 IEC 947-2 Ordering Information lcs — 20 33 50 — lcs — 15 21 33 — Wire Range #3/0-500 kcmil Cu #4/0-500 kcmil Al 500-750 kcmil Al 500-600 kcmil Cu #3/0-600 kcmil Cu #3/0-500 kcmil Cu List Price $ 31.50 500 kcmil Cu/Al 150.00 76.00 77.00 76.00 Instantaneous Adjustment Trip Range Breaker Ampere Rating 200-300 350-400 Nominal Instantaneous Values +20% Tolerance Low 2 3 4 5 6 7 1250 2000 1960 3140 2140 3430 2320 3710 1430 2290 1610 2570 ■ Built to order. Allow 2–3 weeks for delivery. Type JXD2 and JXD6 circuit breakers are UL Listed for reverse feed applications. When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. 6-40 1790 2860 +20% Tolerance High 2500 4000 See Note: A, page 6-81. type circuit breakers meet the UL criteria for “current limiting” at 240 and 480V AC. HACR rated. Note: JD frame qualified to UL489 supplement B “NAVAL.” See page 6-84 for additional information. HHJD6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Modifications page 6-84 Enclosures Section 5 Accessories pages 6-43 and 6-86 to 6-91 Discount Schedule MCCB Molded Case Circuit Breakers JD 400A Frame Sentron Series Selection/Dimensions Black Label Type HJD6-A, HJXD6-A Interchangeable Trip Complete Breaker Unassembled with Lugs Frame Only Catalog Number Catalog Number List Price $ Trip Unit Only List Price $ Catalog Number List Price $ 3441.00 JD62T200■ JD62T225■ JD62T250■ JD62T300■ JD62T350■ JD62T400 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 D1 Continuous Current Rating @ 40°C L 2-Pole 600V AC, 250V DC (3-Pole Width) 3-Pole 600V AC, 500V DC 200 225 250 300 350 400 HJD63B200 HJD63B225 HJD63B250 HJD63B300 HJD63B350 HJD63B400 Type HHJD6, 6538.00 6538.00 6538.00 6538.00 6538.00 6538.00 HJD63F400 4279.00 HHJXD6 HHJD63B200 HHJD63B225 HHJD63B250 HHJD63B300 HHJD63B350 HHJD63B400 7841.00 7841.00 7841.00 7841.00 7841.00 7841.00 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 Black Label HHJD62F400■ 4538.00 JD62T200■ JD62T225■ JD62T250■ JD62T300■ JD62T350■ JD62T400 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 3-Pole 600VAC 200 225 250 300 350 400 HHJD63F400 5582.00 Type CJD6-A Red Label Fuseless Current Limiting Non-Interchangeable Trip (Assembled Circuit Breakers Without Lugs) Continuous Current Rating @ 40°C 200 225 250 300 350 400 2-Pole 3-Pole 600V AC/250V DC 600V AC/500V DC For 2-pole application use outside poles of 3-pole circuit breaker Catalog Number List Price $ CJD63B200■ CJD63B225■ CJD63B250■ CJD63B300■ CJD63B350■ CJD63B400 8167.00 8167.00 8167.00 8167.00 8167.00 8167.00 W Figure 2 Dimensions (in inches) D To Handle D1 Figure 1 JXD2-A, JXD6-A, JD6-A HJD6-A, HJXD6-A, HHJD6, 7.5 11 HJD6, HJXD6, HHJXD6, JXD6-ETI , SJD6, SHJD6 4 5.44 Figure 2 CJD6, CJD6-ETI , SCJD6 4 5.44 Breaker Type W L 7.5 17.86 Enclosures (Except SCJD6) Type Catalog Number List Price $ 1 3R 12 4X 7, 9 (200-250A) 7, 9 (300-400A) J6N1 J6N3R J6N12 LD6SS4 EC4 EE 258.00 1393.00 725.00 6946.00 4815.00 6662.00 Neutral W60992 492.00 Shipping Weights Number of Number per Shipping Poles Carton Weight (lbs.) JXD2, JXD6, JD6, HJD6, HHJD6 Assembled Breaker (less terminals) 2 1 17.5 3 1 19.5 JD6, HJD6, HHJD6 Frame Only 2 1 14 3 1 15.5 JD6 Trip Unit Only 2 1 03.5 3 1 04 CJD6 Complete Assembled Breaker (less terminals) 2 1 29.5 3 1 31.5 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. 2-pole units available in 3-pole construction. When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. Discount Schedule MCCB For non-interchangeable 3-pole HJD6 or HHJD6 type circuit breaker change the prefix identifier to HJXD6 or HHJXD6. Price equals price of frame plus price of trip, e.g. price of HJXD63B400 equals price of HJD63F400 plus price of JD63T400. Order lugs separately. JXD6-ETI, CJD6-ETI see page 6-66 for ordering information. HJXD6, HHJXD6 Circuit Breakers are UL listed for reverse fed applications. CE applies to non-interchangeable type HJXD6-A only. HACR rated. Type Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-41 MOLDED CASE CIRCUIT BREAKERS 6523.00 6523.00 6523.00 6523.00 6523.00 6523.00 6 HHJD62B200■ HHJD62B225■ HHJD62B250■ HHJD62B300■ HHJD62B350■ HHJD62B400■ Figure 1 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400 2-Pole 600V AC (3-Pole Width) 200 225 250 300 350 400 W D HJD62F400■ L 5426.00 5426.00 5426.00 5426.00 5426.00 5426.00 D HJD62B200■ HJD62B225■ HJD62B250■ HJD62B300■ HJD62B350■ HJD62B400■ 200 225 250 300 350 400 Molded Case Circuit Breakers SJD 400A Frame Digital Solid State Sentron Sensitrip III Series Current Limiting Type SJD6-A Type SHJD6-A Blue Label 3-Pole, 600V AC Catalog Number SJD69200■ SJD69300■ SJD69400■ SJD69200G■ SJD69300G■ SJD69400G■ SJD69200NT■ SJD69300NT■ SJD69400NT■ SJD69200NGT■ SJD69300NGT■ SJD69400NGT■ Red Label 3-Pole, 600V AC Max Current List Rating Price $ 200 300 400 4564.00 4564.00 4564.00 200 300 400 7302.00 7302.00 7302.00 200 300 400 6200.00 6200.00 6200.00 200 300 400 9164.00 9164.00 9164.00 Ordering Information Type SCJD6-A Black Label 3-Pole, 600V AC Max Current List Rating Price $ Catalog Number SHJD69200■ SHJD69300■ SHJD69400■ SHJD69200G■ SHJD69300G■ SHJD69400G■ SHJD69200NT■ SHJD69300NT■ SHJD69400NT■ SHJD69200NGT■ SHJD69300NGT■ SHJD69400NGT■ 200 300 400 6500.00 6500.00 6500.00 200 300 400 9164.00 9164.00 9164.00 200 300 400 8048.00 8048.00 8048.00 200 300 400 11116.00 11116.00 11116.00 Max Current List Rating Price $ Catalog Number SCJD69200■ SCJD69300■ SCJD69400■ SCJD69200G■ SCJD69300G■ SCJD69400G■ SCJD69200NT■ SCJD69300NT■ SCJD69400NT■ SCJD69200NGT■ SCJD69300NGT■ SCJD69400NGT■ Selection 200 300 400 8649.00 8649.00 8649.00 200 300 400 11739.00 11739.00 11739.00 200 300 400 10389.00 10389.00 10389.00 200 300 400 14334.00 14334.00 14334.00 Pricing information for all Digital Sentron Series SJD frames is for complete breaker only – price required lugs as separate items – lugs are suitable for 75° C wire. SJD6 and SCJD6 are acceptable for reverse connection application. SHJD6 are not acceptable for reverse connection application. Shipping Weights Breaker Type Number per Carton Shipping Weight (lbs) SJD6-A SHJD6-A SCJD6-A 1 1 1 20 20 33 SJD 400A Frame – 100% Rated 햳 Type SJD6-A Blue Label 6 MOLDED CASE CIRCUIT BREAKERS SJD69200H■ SJD69300H■ SJD69400H■ SJD69200GH■ SJD69300GH■ SJD69400GH■ SJD69200NTH■ SJD69300NTH■ SJD69400NTH■ SJD69200NGTH■ SJD69300NGTH■ SJD69400NGTH■ No of Cables Catalog per ConNumber nector 2 TA2J6500 2 1 TA1L6750 1 TC1J6600 1 TC2J6500 2 TA2J630 2 Compression Lug CCL600 (1 pc.) Black Label 3-Pole, 600V AC Catalog Number Lugs for 75° C Wire 햲 Type SHJD6-A 3-Pole, 600V AC Max Current Rating Max Current List Rating Price $ List Price $ Catalog Number 200 300 400 5007.00 5007.00 5007.00 200 300 400 8048.00 8048.00 8048.00 200 300 400 6819.00 6819.00 6819.00 200 300 400 10071.00 10071.00 10071.00 SHJD69200H■ SHJD69300H■ SHJD69400H■ SHJD69200GH■ SHJD69300GH■ SHJD69400GH■ SHJD69200NTH■ SHJD69300NTH■ SHJD69400NTH■ SHJD69200NGTH■ SHJD69300NGTH■ SHJD69400NGTH■ 200 300 400 7159.00 7159.00 7159.00 200 300 400 10088.00 10088.00 10088.00 200 300 400 8827.00 8827.00 8827.00 200 300 400 12238.00 12238.00 12238.00 Short Time Pick Up Short Time Delay Short Time l2t Pick Up ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Trip Type Cont Current Setting Long Time Delay Instantaneous Setting None LI ⻫ ⻫ ⻫ G LIG ⻫ ⻫ ⻫ NT LSI ⻫ ⻫ NGT LSIG ⻫ ⻫ #1/0-500 kcmil Cu/Al 150.00 Neutral Transformers Trip Unit Adjustable Functions Suffix Letter Code Wire List Range Price $ #3/0-500 kcmil Cu 31.50 #4/0-500 kcmil Cu 31.50 500–750 kcmil Cu/Al 76.00 500–600 kcmil Cu 76.00 #3/0-600 kcmil Cu 77.00 #3/0-500 kcmil Cu 76.00 #4–#3/0-Cu/Al 32.50 Ground Fault Pick Up Ground Fault Delay ⻫ ⻫ ⻫ ⻫ Ampere Rating Catalog Number List Price $ 200 300 400 N02SJD N03SJD N04SJD 396.00 396.00 396.00 Interrupting Ratings Breaker Type RMS Symmetrical kA UL 489 (File E10848) 240V AC 480V AC 600V AC SJD6-A SHJD6-A SCJD6-A 065 100 200 035 065 150 025 035 100 Note: “G” suffix in catalog number denotes circuit breaker for 3-phase, 3-wire systems. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. 6-42 ■ Built to order. Allow 2–3 weeks for delivery. Enclosures Section 5 Accessories pages 6-43 and 6-86 to 6-91 햲 For additional information, see Note: A, page 6-81. to the NEC for proper app lication of 100% rated devices. 햳 Refer Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories Accessories for: JD 400A Frame LD 600A Frame LMD 800A Frame SJD 400A Frame SLD 600A Frame Selection Shunt Trip Combinations 1 Shunt Trip and 1 Auxiliary Switch Control Voltage 1 Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ S17JLD6 S18JLD6▲ S01JLD6 S03JLD6 S15JLD6▲ S04JLD6 636.00 636.00 636.00 636.00 636.00 636.00 — — S01JLD62A S03JLD62A S15JLD64A▲ — —-—-897.00 897.00 897.00 —-- S16JLD6▲ S07JLD6 S09JLD6▲ S11JLD6 S13JLD6▲ 636.00 636.00 636.00 636.00 636.00 S16JLD62A▲ S07JLD62A S09JLD62A S11JLD62A▲ S13JLD62A▲ 897.00 897.00 897.00 897.00 897.00 DC 024 048 120 240 277 480 012 024 048 125 250 Undervoltage Trip Combinations Control Voltage AC Sensitrip Ammeter 1 Undervoltage Trip and 1 Auxiliary Switch 1 Undervoltage Trip DC 120 208 240 480 024 048 125 250 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ U01JLD6 U02JLD6▲ U03JLD6 U06JLD6 636.00 636.00 636.00 636.00 U01JLD62A U02JLD62A▲ U03JLD62A▲ U06JLD64A▲ 897.00 897.00 897.00 897.00 U01JLD62AA U02JLD62AA▲ U03JLD62AA▲ U06JLD64AA▲ 1157.00 1157.00 1157.00 1157.00 U13JLD6 U14JLD6▲ U10JLD6▲ U12JLD6▲ 636.00 636.00 636.00 636.00 U13JLD62A U14JLD62A▲ U10JLD62A▲ U12JLD62A▲ 897.00 897.00 897.00 897.00 U13JLD62AA U14JLD62AA▲ U10JLD62AA▲ U12JLD62AA▲ 1157.00 1157.00 1157.00 1157.00 Auxiliary Switch Combinations DC Catalog Number List Price $ Catalog Number List Price $ 480 250 A01JLD64 271.00 A02JLD64 540.00 — 12 A01JLDLV 342.00 A02JLDLV 684.00 Alarm Switch Combinations Maximum Voltage Note: Accessory modules can only be added to right side pole of solid state SJD and SLD frame circuit breakers. No accessories can be added if mechanical interlock is used. All accessories on this page are useable on superseded JD2, JJ6, JL6, HJ6, SJL, LJ6, LL6, HL6 and SLL circuit breakers. Discount Schedule MCCB 1 Alarm Switch and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch and 2 Auxiliary Switches AC DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 480 250 B01JLD64 271.00 A01JLD64B 540.00 A02JLD64B 802.00 Plug-in Ammeter Display Units Breaker Type The Ammeter may also be panel or door mounted using the SADURMK18 remote mounting kit. 2 Form C SJD, SLD Description Catalog Number List Price $ Display Unit SADU 1776.00 Remote Mounting Kit SADURMK18 342.00 ▲ Built to order. Allow 6–8 weeks for delivery. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-43 MOLDED CASE CIRCUIT BREAKERS Ammeter Mounting Kit 1 Form C AC 6 The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phase current flowing in the breaker. They are powered by the breaker’s CT’s with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status. Maximum Voltage Molded Case Circuit Breakers LD 600A Frame Sentron Series Selection Type LXD6-A Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) 2-Pole (3-Pole 600V AC Catalog Number LXD62B450■ LXD62B500■ LXD62B600 Continuous Current Rating @ 40°C 450 500 600 Width) 250V DC List Price $ 4893.00 4893.00 4893.00 3-Pole 600V AC Catalog Number LXD63B450 LXD63B500 LXD63B600 Type LD6-A 500V DC List Price $ 6102.00 6102.00 6102.00 Blue Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog List Number Price $ Frame Only Catalog Number List Price $ Trip Unit Only Catalog List Number Price $ 2-Pole 600V AC, 250V DC (3-Pole Width) LD62B250■ LD62B300■ LD62B350■ LD62B400 LD62B450■ LD62B500■ LD62B600 250 300 350 400 450 500 600 5020.00 5020.00 5020.00 5020.00 5020.00 5020.00 5020.00 LD62F600 3035.00 JD62T250■ JD62T300■ JD62T350■ JD62T400 LD62T450■ LD62T500■ LD62T600 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 4031.00 JD63T250 JD63T300 JD63T350 JD63T400 LD63T450 LD63T500 LD63T600 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 3-Pole 600V AC, 500V DC MOLDED CASE CIRCUIT BREAKERS 6 250 300 350 400 450 500 600 LD63B250 LD63B300 LD63B350 LD63B400 LD63B450 LD63B500 LD63B600 6290.00 6290.00 6290.00 6290.00 6290.00 6290.00 6290.00 LD63F600 Interrupting Ratings RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC (50/60Hz) Volts DC Breaker Type 240 LD6-A, LXD6-A HLD6-A, HLXD6-A HHLD6, HHLXD6 CLD6-A 065 100 200 200 480 035 065 100 150 600 025 035 050 100 250 IEC 947-2 Volts AC (50/60Hz) 500 220/240 (lcu) (lcs) 25 (3-P) 065 033 35 (3-P) 100 050 — 200 100 50 (3-P) — — 30 (2-P) 30 (2-P) — — Breaker Ampere Rating 250-300 350-450 500-600 4 1790 2860 4290 5 1960 3140 4710 6 2140 3430 5140 380/415 (lcu) (lcs) 040 20 065 33 100 50 — — 7 2320 3710 5570 Complete Breaker Unassembled with Lugs Prices of LD6, HLD6, and HHLD6 breakers include frame, trip, and both line and load lugs (TA2J6500). When ordered by these catalog numbers, the customer will receive the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of LXD6, HLXD6, HHLXD6, and CLD6 include frame with noninterchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA2J6500) installed, add suffix “L” to catalog number (add 2 times list price of lugs for each pole). 100% Rated Types LXD6 and HLXD6 breakers are available with 100% ratings. To order add suffix “H” to catalog number, and 10% to list price. 100% rated LD breakers require the use of 90°C Cu cable sized at 75°C ampacity and lugs TC1J6600 or TC2J6500. 50°C Applications see page 6-84. 400Hz Applications see page 6-84. Shipping Weights 500 (lcu) 30 42 65 — (lcs) 15 21 33 — Instantaneous Adjustment Trip Range Nominal Instantaneous Values +20% Tolerance Low 2 3 1250 1430 1610 2000 2290 2570 3000 3430 3800 Ordering Information +20% Tolerance High 2500 4000 6000 Number of Number per Shipping Poles Carton Weight (lbs.) LXD6, LD6, HLD6, HHLD6 Assembled Breaker (less terminals) 2 1 17.5 3 1 19.5 LD6, HLD6, HHLD6 Frame Only 2 1 14 3 1 15.5 LD6, HHLD6 Trip Unit Only 2 1 03.5 3 1 04 CLD6 Complete Assembled Breaker (less terminals) 2 3 1 1 29.5 31.5 Lugs For 75°C Wire ■ Built to order. Allow 2–3 weeks for delivery. Type LXD6A circuit breakers are UL Listed for reverse fed applications. wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. See Note: A, page 6-81. HACR rated. Note: LD frame qualified to UL489 supplement SB “NAVAL”. See page 6-84 for additional information. When 6-44 Modifications page 6-84 Enclosures Section 5 Accessories pages 6-47 and 6-86 to 6-91 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Cables Catalog per Number Lug TA2J6500 1, 2 2 TC2J6500 2 TA1L6750 1 1 TC1J6600 1 Compression Lug CCL600 1 Wire Range #3/0 500 kcmil Cu #4/0 500 kcmil Al #3/0-500 kcmil Cu 500-750 kcmil Al 500-600 kcmil Cu #3/0-600 kcmil Cu List Price $ 31.50 500 kcmil Cu/Al 150.00 76.00 76.00 77.00 Discount Schedule MCCB Molded Case Circuit Breakers LD 600A Frame Sentron Series Selection/Dimensions Type HLD6-A, HLXD6-A Black Label Interchangeable Trip Frame Only Catalog Number Catalog Number List Price $ Trip Unit Only List Price $ Catalog Number List Price $ D1 Complete Breaker Unassembled w/Lugs Continuous Current Rating @ 40°C L 2-Pole 600V AC, 250V DC (3-Pole Width) 3-Pole 600V AC, 500V 250 300 350 400 450 500 600 HLD62F600■ 4578.00 JD62T250■ JD62T300■ JD62T350■ JD62T400 LD62T450■ LD62T500■ LD62T600 HLD63F600 6090.00 JD63T250 JD63T300 JD63T350 JD63T400 LD63T450 LD63T500 LD63T600 8184.00 8184.00 8184.00 8184.00 8184.00 8184.00 8184.00 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 Black Label HHLD62F600■ 6199.00 JD62T250■ JD62T300■ JD62T350■ JD62T400 HHLD62T450■ HHLD62T500■ HHLD62T600■ 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 W D Figure 2 Figure 1 Dimensions (in inches) To Handle Breaker Type 2-Pole 600V AC (3-Pole Width) HHLD62B250■ HHLD62B300■ HHLD62B350■ HHLD62B400■ HHLD62B450■ HHLD62B500■ HHLD62B600■ W 8349.00 8349.00 8349.00 8349.00 8349.00 8349.00 8349.00 Type HHLD6, HHLXD6 W Figure 1 LXD6-A, LD6-A HLD6-A HHLD6, HHLXD6, LXD6–ETI, SLD6, SHLD6 Figure 2 CLD6, CLD6-ETI, SCLD6 L D D1 7.5 11 4 5.44 7.5 17.86 4 5.44 9914.00 9914.00 9914.00 9914.00 9914.00 9914.00 9914.00 HHLD63F600 7655.00 JD63T250 JD63T300 JD63T350 JD63T400 HHLD63T450■ HHLD63T500■ HHLD63T600■ Type CLD6-A 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 2070.00 Type Catalog Number List Price $ 1 3R 12 4X 7,9 LD6N1 LD6N3R LD6N12 LD6SS4 ED6 449.00 1618.00 979.00 6946.00 11330.00 Neutral W60993 436.00 Red Label Fuseless Current Limiting Non-Interchangeable Trip (Assembled Circuit Breaker) 2-Pole 3-Pole Continuous Current Rating @ 40°C 600V AC/250V DC 600V AC/500V DC 450 500 600 For 2-pole application use outside poles of 3-pole circuit breaker Catalog Number CLD63B450■ CLD63B500 CLD63B600 List Price $ 13045.00 13045.00 13045.00 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. Type HLXD6, HHLXD6, & CLD6 Circuit Breakers are UL Listed for reverse feed applications. CLD6-ETI see page 6-66 for ordering information. CE Applies to non-interchangeable type HLXD only. HACR rated. When HHLD6 to HLXD6 or HHLXD6. Price is sum of frame and trip units prices, e.g. price of HLXD63B400 is the price of HLD63F600 plus the price of LD63T600. Order the terminal connectors separately.■ Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. For complete assembled 3-pole HLD6 or HHLD6 type circuit breaker change the prefix identifier HLD6 or LXD6-ETI, 6-45 MOLDED CASE CIRCUIT BREAKERS HHLD63B250 HHLD63B300 HHLD63B350 HHLD63B400 HHLD63B450■ HHLD63B500■ HHLD63B600■ 6 Enclosures: (except SCLD6) 3-Pole 600V AC 250 300 350 400 450 500 600 L DC HLD63B250 HLD63B300 HLD63B350 HLD63B400 HLD63B450 HLD63B500 HLD63B600 250 300 350 400 450 500 600 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 1859.00 D 6563.00 6563.00 6563.00 6563.00 6563.00 6563.00 6563.00 HLD62B250■ HLD62B300■ HLD62B350■ HLD62B400■ HLD62B450■ HLD62B500■ HLD62B600■ 250 300 350 400 450 500 600 Molded Case Circuit Breakers SLD 600A Frame Digital Solid State Sentron Sensitrip III Series Current Limiting Type SLD6-A Blue Label Black Label 3-Pole, 600V AC SLD69300■ SLD69400■ SLD69500■ SLD69600■ SLD69300G■ SLD69400G■ SLD69500G■ SLD69600G■ SLD69300NT■ SLD69400NT■ SLD69500NT■ SLD69600NT■ SLD69300NGT■ SLD69400NGT■ SLD69500NGT■ SLD69600NGT■ Red Label 3-Pole, 600V AC 3-Pole, 600V AC Max List Current Price Rating $ Catalog Number Max List Current Price Rating $ Catalog Number 300 400 500 600 6235.00 6235.00 6235.00 6235.00 300 400 500 600 8847.00 8847.00 8847.00 8847.00 300 400 500 600 7834.00 7834.00 7834.00 7834.00 300 400 500 600 10890.00 10890.00 10890.00 10890.00 SHLD69300■ SHLD69400■ SHLD69500■ SHLD69600■ SHLD69300G■ SHLD69400G■ SHLD69500G■ SHLD69600G■ SHLD69300NT■ SHLD69400NT■ SHLD69500NT■ SHLD69600NT■ SHLD69300NGT■ SHLD69400NGT■ SHLD69500NGT■ SHLD69600NGT■ Ordering Information Type SCLD6-A Type SHLD6-A 300 400 500 600 7593.00 7593.00 7593.00 7593.00 300 400 500 600 10706.00 10706.00 10706.00 10706.00 300 400 500 600 9401.00 9401.00 9401.00 9401.00 300 400 500 600 12989.00 12989.00 12989.00 12989.00 Max List Current Price Rating $ Catalog Number SCLD69300■ SCLD69400■ SCLD69500■ SCLD69600■ SCLD69300G■ SCLD69400G■ SCLD69500G■ SCLD69600G■ SCLD69300NT■ SCLD69400NT■ SCLD69500NT■ SCLD69600NT■ SCLD69300NGT■ SCLD69400NGT■ SCLD69500NGT■ SCLD69600NGT■ 300 400 500 600 13446.00 13446.00 13446.00 13446.00 300 400 500 600 17758.00 17758.00 17758.00 17758.00 300 400 500 600 15914.00 15914.00 15914.00 15914.00 300 400 500 600 20940.00 20940.00 20940.00 20940.00 6 MOLDED CASE CIRCUIT BREAKERS Pricing information for all Digital Sentron Series SLD frames is for complete breaker only – price required lugs as separate items – lugs are suitable for 75° C wire. SLD6 and SCLD6 are suitable for reverse connection application. SHLD6 are not suitable for reverse connection application. Shipping Weights Breaker Type Number per Carton Shipping Weight (lbs) SLD6-A SHLD6-A SCLD6-A 1 1 1 20 20 33 Neutral Transformers Trip Unit Adjustable Functions Suffix Letter Code Selection Short Time Pick Up Short Time Delay Short Time l2t Pick Up ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Trip Type Cont Current Setting Long Time Delay Instantaneous Setting None LI ⻫ ⻫ ⻫ G LIG ⻫ ⻫ ⻫ NT LSI ⻫ ⻫ NGT LSIG ⻫ ⻫ Ground Fault Pick Up Ground Fault Delay ⻫ ⻫ ⻫ ⻫ Ampere Rating Catalog Number List Price $ 300 400 500 600 N03SJD N04SJD N05SLD N06SLD 396.00 396.00 396.00 396.00 Interrupting Ratings Breaker Type RMS Symmetrical kA UL 489 (File E10848) 240V AC 480V AC 600V AC SLD6-A SHLD6-A SCLD6-A 065 100 200 035 065 150 025 035 100 Note: “G” suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. 6-46 For ordering information and terminal connectors see page 6-44; for enclosures, see page 6-45. ■ Built to order. Allow 2–3 weeks for delivery. 100% Rated – Not available in SLD6 Frame. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories Accessories for: JD 400A Frame LD 600A Frame LMD 800A Frame SJD 400A Frame SLD 600A Frame Selection Shunt Trip Combinations 1 Shunt Trip and 1 Auxiliary Switch Control Voltage 1 Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ S17JLD6 S18JLD6▲ S01JLD6 S03JLD6 S15JLD6▲ S04JLD6 636.00 636.00 636.00 636.00 636.00 636.00 — — S01JLD62A S03JLD62A S15JLD64A▲ — —-—-897.00 897.00 897.00 —-- S16JLD6▲ S07JLD6 S09JLD6▲ S11JLD6 S13JLD6▲ 636.00 636.00 636.00 636.00 636.00 S16JLD62A▲ S07JLD62A S09JLD62A S11JLD62A▲ S13JLD62A▲ 897.00 897.00 897.00 897.00 897.00 DC 024 048 120 240 277 480 012 024 048 125 250 Undervoltage Trip Combinations Control Voltage AC Sensitrip Ammeter 1 Undervoltage Trip and 1 Auxiliary Switch 1 Undervoltage Trip DC 120 208 240 480 024 048 125 250 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ U01JLD6 U02JLD6▲ U03JLD6 U06JLD6 636.00 636.00 636.00 636.00 U01JLD62A U02JLD62A▲ U03JLD62A▲ U06JLD64A▲ 897.00 897.00 897.00 897.00 U01JLD62AA U02JLD62AA▲ U03JLD62AA▲ U06JLD64AA▲ 1157.00 1157.00 1157.00 1157.00 U13JLD6 U14JLD6▲ U10JLD6▲ U12JLD6▲ 636.00 636.00 636.00 636.00 U13JLD62A U14JLD62A▲ U10JLD62A▲ U12JLD62A▲ 897.00 897.00 897.00 897.00 U13JLD62AA U14JLD62AA▲ U10JLD62AA▲ U12JLD62AA▲ 1157.00 1157.00 1157.00 1157.00 Auxiliary Switch Combinations DC Catalog Number List Price $ Catalog Number List Price $ 480 250 A01JLD64 271.00 A02JLD64 540.00 — 12 A01JLDLV 342.00 A02JLDLV 684.00 Alarm Switch Combinations Maximum Voltage Note: Accessory modules can only be added to right side pole of solid state SJD and SLD frame circuit breakers. No accessories can be added if mechanical interlock is used. All accessories on this page are useable on superseded JD2, JJ6, JL6, HJ6, SJL, LJ6, LL6, HL6 and SLL circuit breakers. Discount Schedule MCCB 1 Alarm Switch and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch and 2 Auxiliary Switches AC DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 480 250 B01JLD64 271.00 A01JLD64B 540.00 A02JLD64B 802.00 Plug-in Ammeter Display Units Breaker Type The Ammeter may also be panel or door mounted using the SADURMK18 remote mounting kit. 2 Form C SJD, SLD Description Catalog Number List Price $ Display Unit SADU 1776.00 Remote Mounting Kit SADURMK18 342.00 ▲ Built to order. Allow 6–8 weeks for delivery. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-47 MOLDED CASE CIRCUIT BREAKERS Ammeter Mounting Kit 1 Form C AC 6 The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phase current flowing in the breaker. They are powered by the breaker’s CT’s with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status. Maximum Voltage Molded Case Circuit Breakers LMD 800A Frame Sentron Series Selection Type LMXD6 Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) 2-Pole (3-Pole Width) Catalog List Number Price $ — — LMXD62B600■ 6242.00 LMXD62B700■ 6242.00 LMXD62B800 6242.00 Continuous Current Rating @ 40°C 500 600 700 800 3-Pole Catalog Number LMXD63B500■ LMXD63B600 LMXD63B700 LMXD63B800 List Price $ 7902.00 7902.00 7902.00 7902.00 Blue Label Type LMD6 Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog List Number Price $ Frame Only Catalog Number List Price $ Trip Unit Only Catalog Number List Price $ LMD62T500■ LMD62T600■ LMD62T700■ LMD62T800■ 2987.00 2987.00 2987.00 2987.00 LMD63T500■ LMD63T600■ LMD63T700■ LMD63T800 3747.00 3747.00 3747.00 3747.00 2-Pole 600V AC, 250V DC (3-Pole Width) LMD62B500■ LMD62B600■ LMD62B700■ LMD62B800■ 500 600 700 800 6632.00 6632.00 6632.00 6632.00 LMD62F800■ 3253.00 LMD63F800 4156.00 3-Pole 600V AC, 500V DC LMD63B500■ LMD63B600■ LMD63B700■ LMD63B800 500 600 700 800 8491.00 8491.00 8491.00 8491.00 Instantaneous Adjustment Trip Range 500-600 700-800 Complete Breaker Unassembled with Lugs Prices of LMD6 and HLMD6 breakers include frame, trip, and both line and load lugs (TA3K500). These catalog numbers include the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of LMXD6 and HLMXD6 include frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA3K500) installed, add suffix “L” to catalog number (add 2 times list price of lugs for each pole). 50°C Applications see page 6-84. 400Hz Applications see page 6-84. Shipping Weights 4 5 6 7 4290 4200 4710 4700 5140 6400 5570 7300 High +/- 20% Tolerance 6000 8000 MOLDED CASE CIRCUIT BREAKERS 6 Ampere Rating Nominal Instantaneous Values Low +/- 20% 2 3 Tolerance 3000 3430 3860 3200 3500 3700 Ordering Information Number of Poles Number per Carton Shipping Weight (lbs.) LMD6, HLMD6, LMXD6, HLMXD6 Complete Breaker (less terminals) 2 3 1 1 53 61.5 LMD6, HLMD6 Frame Only 2 3 1 1 42.25 46 LMD6, HLMD6 Trip Unit Only 2 3 1 1 4.5 6.5 Lugs for 75°C Wire Catalog Number TA2K500 TA3K500 TA2N750 ■ Built to order. Allow 2–3 weeks for delivery. LMXD6 circuit breakers are UL Listed for reverse connected applications. wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. See Note: A, page 6-81. rated. HACR Cables per Lug 1, 2 1-3 1, 2 Wire Range #1-500 kcmil Cu/Al #1/0-500 kcmil Cu/Al 500-750 kcmil Cu/Al List Price $ 71.00 98.00 101.00 Modifications page 6-84 Enclosures Section 5 Accessories pages 6-50 and 6-81 to 6-91 When 6-48 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers LMD 800A Frame Sentron Series Selection/Dimensions Type HLMXD6 Black Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) 2-Pole 3-Pole Continuous Current Rating @ 40°C 600V AC/250V DC 600V AC/500V DC 500 600 700 800 For 2-pole application use outside poles of 3-pole circuit breaker Catalog Number List Price $ HLMXD63B500■ HLMXD63B600■ HLMXD63B700■ HLMXD63B800 9564.00 9564.00 9564.00 9564.00 Type HLMD6 Black Label Interchangeable Trip Continuous Current Rating @ 40°C D1 D W Complete Breaker Unassembled Frame Only Catalog Number Catalog Number List Price $ Trip Unit Only List Price $ Catalog Number List Price $ HLMD62F800■ 4526.00 LMD62T500■ LMD62T600■ LMD62T700■ LMD62T800■ 2987.00 2987.00 2987.00 2987.00 HLMD63F800 5819.00 LMD63T500 ■ LMD63T600 ■ LMD63T700 ■ LMD63T800 3747.00 3747.00 3747.00 3747.00 2-Pole 600V AC, 250V DC (3-Pole Width) 500 600 700 800 HLMD62B500■ HLMD62B600■ HLMD62B700■ HLMD62B800■ 7905.00 7905.00 7905.00 7905.00 L 3-Pole 600V AC, 500V DC 500 600 700 800 HLMD63B500 HLMD63B600 HLMD63B700 HLMD63B800 10154.00 10154.00 10154.00 10154.00 480 50 065 600 25 050 250 30 (2-P) 30 (2-P) L D D1 7.5 16 4.5 5.93 500 500 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs) 25 (3-P) 065 033 040 20 30 15 50 (3-P) 100 050 065 33 42 21 Enclosures Type Catalog Number List Price $ 1 3R 12 LMD1 LMD3R LMD12■ 897.00 2202.00 2883.00 Neutral W63623 606.00 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. HLMXD6 circuit breakers are UL Listed for reverse connection applications. LMXD6-ETI, see page 6-66 for catalog information. Discount Schedule MCCB When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. HACR rated. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-49 MOLDED CASE CIRCUIT BREAKERS 240 65 100 W 6 Breaker Type LMD6, LMXD6 HLMD6, HLMXD6 IEC 947-2 Volts AC (50/60HZ) 220/240 380/415 Breaker Type LMD6, LMXD6, HLMD6, HLMXD6 LMXD6-ETI Interrupting Ratings UL 489A IR RMS Symmetrical Amperes (KA) Volts AC Volts DC Dimensions (in inches) Molded Case Circuit Breakers Internal Accessories Accessories for: JD 400A Frame LD 600A Frame LMD 800A Frame SJD 400A Frame SLD 600A Frame Selection Shunt Trip Combinations 1 Shunt Trip and 1 Auxiliary Switch Control Voltage 1 Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ S17JLD6 S18JLD6▲ S01JLD6 S03JLD6 S15JLD6▲ S04JLD6 636.00 636.00 636.00 636.00 636.00 636.00 — — S01JLD62A S03JLD62A S15JLD64A▲ — —-—-897.00 897.00 897.00 —-- S16JLD6▲ S07JLD6 S09JLD6▲ S11JLD6 S13JLD6▲ 636.00 636.00 636.00 636.00 636.00 S16JLD62A▲ S07JLD62A S09JLD62A S11JLD62A▲ S13JLD62A▲ 897.00 897.00 897.00 897.00 897.00 DC 024 048 120 240 277 480 012 024 048 125 250 Undervoltage Trip Combinations Control Voltage AC Sensitrip Ammeter 1 Undervoltage Trip and 1 Auxiliary Switch 1 Undervoltage Trip DC 120 208 240 480 024 048 125 250 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ U01JLD6 U02JLD6▲ U03JLD6 U06JLD6 636.00 636.00 636.00 636.00 U01JLD62A U02JLD62A▲ U03JLD62A▲ U06JLD64A▲ 897.00 897.00 897.00 897.00 U01JLD62AA U02JLD62AA▲ U03JLD62AA▲ U06JLD64AA▲ 1157.00 1157.00 1157.00 1157.00 U13JLD6 U14JLD6▲ U10JLD6▲ U12JLD6▲ 636.00 636.00 636.00 636.00 U13JLD62A U14JLD62A▲ U10JLD62A▲ U12JLD62A▲ 897.00 897.00 897.00 897.00 U13JLD62AA U14JLD62AA▲ U10JLD62AA▲ U12JLD62AA▲ 1157.00 1157.00 1157.00 1157.00 MOLDED CASE CIRCUIT BREAKERS 6 Auxiliary Switch Combinations The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phrase current flowing in the SADU breaker. They are powered by the breaker’s CT’s with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status. Ammeter Mounting Kit Maximum Voltage 1 Form C AC DC Catalog Number List Price $ Catalog Number List Price $ 480 250 A01JLD64 271.00 A02JLD64 540.00 — 12 A01JLDLV 342.00 A02JLDLV 684.00 Alarm Switch Combinations Maximum Voltage Note: Accessory modules can only be added to right side pole of solid state SJD and SLD frame circuit breakers. No accessories can be added if mechanical interlock is used. All accessories on this page are useable on superseded JD2, JJ6, JL6, HJ6, SJL, LJ6, LL6, HL6 and SLL circuit breakers. 6-50 1 Alarm Switch and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch and 2 Auxiliary Switches AC DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 480 250 B01JLD64 271.00 A01JLD64B 540.00 A02JLD64B 802.00 Plug-in Ammeter Display Units Breaker Type The Ammeter may also be panel or door mounted using the SADURMK18 remote mounting kit. 2 Form C SJD, SLD Description Catalog Number List Price $ Display Unit SADU 1776.00 Remote Mounting Kit SADURMK18 342.00 ▲ Built to order. Allow 6–8 weeks for delivery. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers MD 800A Frame Sentron Series Selection Type MXD6 Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) 2-Pole Continuous Current Rating @ 40°C 500 600 700 800 3-Pole Catalog Number List Price $ Catalog Number List Price $ MXD62B500■ MXD62B600■ MXD62B700■ MXD62B800■ 6242.00 6242.00 6242.00 6242.00 MXD63B500■ MXD63B600 MXD63B700 MXD63B800 7902.00 7902.00 7902.00 7902.00 Type MD6 Blue Label Interchangeable Trip Continuous Current Setting @ 40°C Complete Breaker Unassembled with Lugs Frame Only Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 6632.00 6632.00 6632.00 6632.00 MD62F800■ 3253.00 MD62T500■ MD62T600■ MD62T700■ MD62T800■ 2987.00 2987.00 2987.00 2987.00 8491.00 8491.00 8491.00 8491.00 MD63F800 4156.00 MD63T500 MD63T600 MD63T700 MD63T800 3747.00 3747.00 3747.00 3747.00 Trip Unit Only 2-Pole 600V AC, 250V DC 500 600 700 800 MD62B500■ MD62B600■ MD62B700■ MD62B800■ 3-Pole 600V AC, 500V DC 500 600 700 800 MD63B500 MD63B600 MD63B700 MD63B800 Lugs Lugs Per Kit Wire Range List Price $ TA2K500 TA3K500 TC2K500 TC3K350 1-2 1-3 1-2 1-3 1 1 1 1 #1-500 kcmil Cu / Al 1/0-500 kcmil Cu / Al #1-500 kcmil Cu #1-350 kcmil Cu 71.00 98.00 120.00 151.00 2TA2N8750 3TA2N8750 1-2 2 3 500-750 kcmil Cu / Al 365.00 513.00 2TA3N8750 3TA3N8750 1-3 2 3 500-750 kcmil Cu / Al 579.00 832.00 2TA4N8500 3TA4N8500 1-4 2 3 250-500 kcmil Cu / Al 588.00 853.00 2TA4P8500 3TA4P8500 1-4 2 3 250-500 kcmil Cu/Al 584.00 843.00 Kits Instantaneous Adjustment Trip Range Ampere Rating 500–600 700–800 Nominal Instantaneous Values Low +/- 20% 2 3 Tolerance 3000 3430 3860 4000 4570 5140 Shipping Weights Number of Number per Poles Carton MD6, HMD6, HMXD6, CMD6 Complete Breaker Assembled (less lugs) 2 1 3 1 Shipping Weight (lbs.) 53 61.5 MD6, HMD6 Frame Only 4 5 6 7 4280 5710 4710 6280 5140 6850 5570 7420 High +/- 20% Tolerance 6000 8000 2 3 1 1 42.25 46 MD6, HMD6 Trip Unit Only 2 3 1 1 4.5 6.5 Enclosures ■ Built to order. Allow 2–3 weeks for delivery. MXD6 circuit breakers are UL Listed for reverse connection applications. 2-pole units available in 3-pole width only. When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. Discount Schedule MCCB See Note: A, page 6-81. rated breakers with the CE mark will also be marked in the 100% rated version. HACR rated. Note: MD frame qualified to UL489 supplement B “NAVAL”. See page 6-84 for additional information. Type Catalog Number List Price $ 1 3R 12 MND61 MND63 MND612■ 897.00 2202.00 2883.00 Neutral W63623 606.00 80% Modifications page 6-84 Enclosures Section 5 Accessories pages 6-54 and 6-86 to 6-91 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-51 MOLDED CASE CIRCUIT BREAKERS Cables Per Lug Complete Breaker Unassembled with Lugs Pricing information for MD6 and HMD6 breakers includes frame, trip, and both line and load lugs (TA3K500). When ordered by these catalog numbers, the customer will receive the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of MXD6, HMXD6 and CMD6 include frame with non-interchangeable trip units installed only. Order required lugs separately. For line and load lugs (TA3K500) installed, add suffix “L” to catalog number (add 2 times list price of lugs for each pole). 100% Rated Types MXD6, HMXD6 and CMD6 breakers are available with 100% ratings. To order add suffix “H” to catalog number, and 10% to list price. 100% rated MD breakers require the use of 90°C Cu cable sized at 75°C ampacity and lugs 2TA4P8500 or 2TA2N8750 for 2-pole; 3TA4P8500 or 3TA2N8750 for 3-pole. 50°C Applications see page 6-84. 400Hz Applications see page 6-84. 6 Catalog Number Ordering Information Molded Case Circuit Breakers MD 800A Frame Sentron Series Selection/Dimensions Type HMXD6 Black Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) 2-Pole 3-Pole Continuous Current Rating @ 40°C 600V AC/250V DC 600V AC/500V DC 500 600 700 800 For 2-pole application use outside poles of 3-pole circuit breaker Catalog Number List Price $ HMXD63B500■ HMXD63B600■ HMXD63B700■ HMXD63B800 9567.00 9567.00 9567.00 9567.00 Type HMD6 Black Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Frame Only Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 7905.00 7905.00 7905.00 7905.00 HMD62F800■ 4526.00 MD62T500■ MD62T600■ MD62T700■ MD62T800■ 2987.00 2987.00 2987.00 2987.00 HMD63F800 5819.00 MD63T500 MD63T600 MD63T700 MD63T800 3747.00 3747.00 3747.00 3747.00 Trip Unit Only 2-Pole 600V AC, 250V DC HMD62B500■ HMD62B600■ HMD62B700■ HMD62B800■ 500 600 700 800 3-Pole 600V AC, 500V DC 500 600 700 800 HMD63B500 HMD63B600 HMD63B700 HMD63B800 10154.00 10154.00 10154.00 10154.00 MOLDED CASE CIRCUIT BREAKERS 6 Type CMD6 Red Label Fuseless Current Limiting Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) 2-Pole 3-Pole Continuous Current Rating @ 40°C 600V AC/250V DC 600V AC/500V DC 500 600 700 800 For 2-pole application use outside poles of 3-pole circuit breaker Lug Catalog Number List Price $ CMD63B500■ CMD63B600■ CMD63B700■ CMD63B800■ 14089.00 14089.00 14089.00 14089.00 Interrupting Ratings HMD6, HMXD6 CMD6 Dimensions (in inches) W L D (To Handle) D1 MD6, MXD6, HMD6, HMXD6, CMD6, MXD6-ETI, CMD6-ETI, SMD6, SHMD6, and SCMD6 9 16 6 8.25 with lug shields 9 24 6 8.25 Breaker Type UL 489 AIR—File E10848 RMS Symmetrical Amperes (KA) Volts AC Volts DC Breaker Type MD6, MXD6 When wire lug shield NDTS is used. Note: NDTS lug shields are required when oversized lugs are used. The kits include the NDTS shield. IEC 947-2 AIR Volts AC (50/60HZ) 220/240 380/415 500 240 065 480 050 600 25 250 30 (2-P) 500 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs 25 (3-P) 065 033 040 20 30 15 100 200 065 100 50 65 30 (2-P) — 50 (3-P) 100 050 065 33 50 (3-P) 200 100 100 50 42 65 21 33 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. HMXD6 and CMD circuit breakers are UL listed for reverse connection applications. 2-pole units available in 3-pole width only. MXD6-ETI, CMD6-ETI see page 6-66 for catalog information. 6-52 When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. HACR rated. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers SMD 800A Frame Digital Solid State Sentron Sensitrip III Series햴 Current Limiting Type SMD6 Blue Label Black Label Red Label 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC Ordering Information Type SCMD6 Type SHMD6 Catalog Number Max Current List Rating Price $ Catalog Number Max Current List Rating Price $ Catalog Number Max Current List Rating Price $ SMD69600A■ SMD69700A■ SMD69800A■ 600 700 800 8595.00 8595.00 8595.00 SHMD69600A■ SHMD69700A■ SHMD69800A■ 600 700 800 10478.00 10478.00 10478.00 SCMD69600A■ SCMD69700A■ SCMD69800A■ 600 700 800 15559.00 15559.00 15559.00 SMD69600AG■ SMD69700AG■ SMD69800AG■ 600 700 800 10214.00 10214.00 10214.00 SHMD69600AG■ SHMD69700AG■ SHMD69800AG■ 600 700 800 12060.00 12060.00 12060.00 SCMD69600AG■ SCMD69700AG■ SCMD69800AG■ 600 700 800 18543.00 18543.00 18543.00 SMD69600ANT■ SMD69700ANT■ SMD69800ANT■ 600 700 800 8896.00 8896.00 8896.00 SHMD69600ANT■ SHMD69700ANT■ SHMD69800ANT■ 600 700 800 10800.00 10800.00 10800.00 SCMD69600ANT■ SCMD69700ANT■ SCMD69800ANT■ 600 700 800 16837.00 16837.00 16837.00 SMD69600ANGT■ 600 SMD69700ANGT■ 700 SMD69800ANGT■ 800 11825.00 11825.00 11825.00 SHMD69600ANGT■ 600 SHMD69700ANGT■ 700 SHMD69800ANGT■ 800 13886.00 13886.00 13886.00 SCMD69600ANGT■ 600 SCMD69700ANGT■ 700 SCMD69800ANGT■ 800 21472.00 21472.00 21472.00 Current Limiting Type SMD6-H Type SCMD6-H Type SHMD6-H Black Label 3-Pole, 600V AC Red Label 3-Pole, 600V AC Max Current List Rating Price $ Catalog Number Max Current List Rating Price $ SMD69600AH■ SMD69700AH■ SMD69800AH■ 600 700 800 9451.00 9451.00 9451.00 SHMD69600AH■ SHMD69700AH■ SHMD69800AH■ 600 700 800 11529.00 11529.00 11529.00 SCMD69600AH■ SCMD69700AH■ SCMD69800AH■ 600 700 800 17114.00 17114.00 17114.00 SMD69600AGH■ SMD69700AGH■ SMD69800AGH■ 600 700 800 11249.00 11249.00 11249.00 SHMD69600AGH■ SHMD69700AGH■ SHMD69800AGH■ 600 700 800 13269.00 13269.00 13269.00 SCMD69600AGH■ SCMD69700AGH■ SCMD69800AGH■ 600 700 800 20408.00 20408.00 20408.00 SMD69600ANTH■ SMD69700ANTH■ SMD69800ANTH■ 600 700 800 9861.00 9861.00 9861.00 SHMD69600ANTH■ 600 SHMD69700ANTH■ 700 SHMD69800ANTH■ 800 11900.00 11900.00 11900.00 SCMD69600ANTH■ SCMD69700ANTH■ SCMD69800ANTH■ 600 700 800 18506.00 18506.00 18506.00 SMD69600ANGTH■ 600 SMD69700ANGTH■ 700 SMD69800ANGTH■ 800 13024.00 13024.00 13024.00 SHMD69600ANGTH■ 600 SHMD69700ANGTH■ 700 SHMD69800ANGTH■ 800 15291.00 15291.00 15291.00 SCMD69600ANGTH■ 600 SCMD69700ANGTH■ 700 SCMD69800ANGTH■ 800 23639.00 23639.00 23639.00 MD MD 500–600 700–800 TA2K500 TA3K500 Types SMD6 and SHMD6 are acceptable for reverse connection applications. Breaker Type Number per Carton Shipping Weight (lbs) All types 1 61.5 Cables Catalog per Wire List Number Lug Range Price $ TA2K500 2 #1-500 kcmil Cu/Al 71.00 TA3K500 3 #1-500 kcmil Cu/Al 98.00 TC2K500 2 #1-500 kcmil Cu 120.00 TC3K350 3 #1-350 kcmil Cu 151.00 Kits (3 lugs/kit) 3TA4N8500 4 250–500 kcmil Cu/Al 853.00 3TA4P8500 4 250–500 kcmil Cu/Al 843.00 3TA2N8750 2 500–750 kcmil Cu/Al 513.00 3TA3N8750 3 500–750 kcmil Cu/Al 832.00 Each kit contains the following: 3TA4P8500—3 connectors plus 1 NDTS end barrier 3TA3N8750—3 connectors plus 1 NDTS end barrier 3TA2N8750—3 connectors plus 1 NDTS end barrier Neutral Transformers Trip Unit Adjustable Functions Trip Type Cont Current Setting Long Time Delay Instantaneous Setting LI ⻫ ⻫ ⻫ AG LIG ⻫ ⻫ ⻫ ANT LSI ⻫ ⻫ ANGT LSIG ⻫ ⻫ Short Time Pick Up Short Time Delay ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Ground Fault Pick Up Ground Fault Delay ⻫ ⻫ ⻫ ⻫ Interrupting Ratings Breaker Type RMS Symmetrical kA UL 489 (File E10848) 240V AC 480V AC 600V AC SMD6 SHMD6 SCMD6 065 100 200 050 065 100 25 50 65 Note: “G” suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. Discount Schedule MCCB Connector or Connector Kit 햲 Use 2-3TA4P8500 for 3-pole. These kits are rated for 90°C wire. 90°C Cu only cable must be used, and sized per 75°C ampacity. 햳 For additional information, see Note: A, page 6-81. 햴 SMD6, SHMD6 and SCMD6 circuit breakers are UL Listed for reverse connection applications. Ampere Rating Catalog Number List Price $ 0600 0700 0800 N06SMDA N07SMDA N08SMDA 423.00 423.00 423.00 Type Catalog Number List Price $ 1 3R 12 MND61 MND63 MND612 897.00 2202.00 2883.00 Neutral W63623 606.00 Enclosures Enclosures Section 5 Accessories pages 6-54 and 6-86 to 6-91 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-53 MOLDED CASE CIRCUIT BREAKERS Catalog Number ■ Built to order. Allow 2–3 weeks for delivery. Ampere Rating 6 Max Current List Rating Price $ A Breaker Frame Lugs for 75°C Wire 햳 3-Pole, 600V AC Catalog Number Suffix Letter Code Pricing information for all Digital Sentron Series MD frames is for complete breaker only. Price requires lugs or lug kits as separate items. Lugs are suitable for 75°C wire or as noted. Connector wire ranges and cavities are established in conjunction with Table 8.1 of UL 489 standards. Choose actual connector for circuit breakers based on customer requirements. Recommended Terminal Connectors Shipping Weights SMD 800A Frame – 100% Rated 햲 Blue Label Selection Molded Case Circuit Breakers Internal Accessories Accessories for: MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame Selection Shunt Trip Combinations 1 Shunt Trip and 1 Auxiliary Switch Control Voltage 1 Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ S01MN6 S02MN6▲ S03MN6 S15MN6▲ S04MN6▲ S06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 S01MN64A — S03MN64A▲ S15MN64A▲ S04MN64A▲ — 897.00 — 897.00 897.00 897.00 — S16MN6▲ S07MN6 S09MN6▲ S11MN6 S13MN6▲ 636.00 636.00 636.00 636.00 636.00 S16MN64A▲ S07MN64A — S11MN64A▲ S13MN64A▲ 897.00 897.00 — 897.00 636.00 DC 120 208 240 277 480 600 012 024 048 125 250 Undervoltage Trip Combinations Control Voltage AC DC Catalog Number 120 208 240 277 480 600 024 048 125 250 List Price $ 1 Undervoltage Trip and 1 Auxiliary Switch 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number List Price $ Catalog Number List Price $ U01MN6 U02MN6▲ U03MN6▲ U15MN6▲ U04MN6▲ U06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 U01MN64A U02MN64A▲ U03MN64A▲ U15MN64A▲ U04MN64A▲ — 897.00 897.00 897.00 897.00 897.00 —-- U01MN64AA U02MN64AA▲ U03MN64AA▲ U15MN64AA▲ U04MN64AA▲ — 1157.00 1157.00 1157.00 1157.00 1157.00 —--- U07MN6 U09MN6▲ U11MN6▲ U13MN6▲ 636.00 636.00 636.00 636.00 U07MN64A U09MN64A▲ U11MN64A▲ U13MN64A▲ 897.00 897.00 897.00 897.00 U07MN64AA U09MN64AA▲ U11MN64AA▲ U13MN64AA▲ 1157.00 1157.00 1157.00 1157.00 Maximum Voltage 1 Form C 6 Auxiliary Switch Combinations AC DC Catalog Number List Price $ Catalog Number 480 250 A01MN64 271.00 A02MN64 540.00 MOLDED CASE CIRCUIT BREAKERS Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole. 1 Undervoltage Trip — 12 A01MNDLV▲ 342.00 A02MNDLV▲ 684.00 Sensitrip Ammeter 2 Form C List Price $ Alarm Switch Combinations Maximum Voltage The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phase current flowing in the breaker. They are powered by the breaker’s CT’s with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status. 1 Alarm Switch and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch and 2 Auxiliary Switches AC DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 480 250 B00MN64 540.00 271.00 A01MN64B A02MN64B 802.00 Plug-in Ammeter Display Units Breaker Type SMD, SND, SPD Description Catalog Number List Price $ Display Unit SADU 1776.00 Remote Mounting Kit SADURMK18 342.00 Ammeter Mounting Kit The Ammeter may also be panel or door mounted using the SADURMK18 remote mounting kit. ▲ Built to order. Allow 6–8 weeks for delivery. 6-54 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers ND 1200A Frame Sentron Series Selection Type NXD6 햲햹 Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) 2-Pole 600V AC 250V DC Continuous Current Rating @ 40°C 3-Pole 600V AC 500V DC Catalog Number List Price $ NXD62B900■ NXD62B100■ NXD62B120■ 0900 1000 1200 Catalog Number 10498.00 10498.00 10498.00 List Price $ NXD63B900 NXD63B100 NXD63B120 Type ND6 햹 13167.00 13167.00 13167.00 Blue Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Frame Only Catalog Number Catalog Number List Price $ Catalog Number List Price $ 9587.00 11675.00 11675.00 11675.00 ND62F120 5424.00 MD62T800■ ND62T900■ ND62T100■ ND62T120 2987.00 5075.00 5075.00 5075.00 12259.00 14874.00 14874.00 14874.00 ND63F120 6806.00 MD63T800 ND63T900 ND63T100 ND63T120 3747.00 6362.00 6362.00 6362.00 List Price $ Trip Unit Only 2-Pole 600V AC, 250V DC 햳 0800 0900 1000 1200 ND62B800■ ND62B900■ ND62B100■ ND62B120 3-Pole 600V AC, 500V DC 햴 0800 0900 1000 1200 ND63B800 ND63B900 ND63B100 ND63B120 Interrupting Ratings 240 480 600 250 500 햴 65 100 200 50 65 100 25 50 65 30 (2-P) 30 (2-P) — 25 (3-P) 50 (3-P) 50 (3-P) 220/240 380/415 (lcu) (lcs) (lcu) (lcs) 65 33 40 20 100 50 65 33 200 100 100 50 500 (lcu) 30 42 65 (lcs) 15 21 33 Instantaneous Adjustment Trip Range Nominal Instantaneous Values Breaker Ampere Rating +20% Tolerance Low 2 3 4 5 6 7 +20% Tolerance High 800 4000 4570 5140 5710 6280 6850 7420 08000 900-1200 5000 5715 6430 7145 7860 8575 9290 10000 Lugs 햷 Catalog Cables Wire Number per Lug Range TA2K500 2 #1-500 kcmil Cu/Al TA3K500 3 #1-500 kcmil Cu/Al TC2K500 2 #1-500 kcmil Cu TC3K350 3 #1-350 kcmil Cu Kits (2 Kits required per breaker) 2TA4P8500 햵 4 250-500 kcmil Cu/Al 3TA4P8500 햵 2TA4N8500 햶 4 250-500 kcmil Cu/Al 3TA4N8500 햶 2TA2N8750 2 500-750 kcmil Cu/Al 3TA2N8750 2TA3N8750 3 500-750 kcmil Cu/Al 3TA3N8750 List Price $ 71.00 98.00 120.00 151.00 584.00 843.00 588.00 853.00 365.00 513.00 579.00 832.00 Enclosures Type 1 3R 12 Neutral ■ Built to order. Allow 2–3 weeks for delivery. 햲 NXD6 circuit breakers are UL listed for reverse connection applications. 햳 2-pole units available in 3-pole width only. 햴 When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. 햵 Use 2 – 3TA4P8500 kits for 3-pole, or 2 – 2TA4P8500 kits for 2-pole. Use for 100% rated breakers. Discount Schedule MCCB Catalog Number MND61 MND63 MND612 ■ W63623 List Price $ 897.00 2202.00 2883.00 606.00 햶 Use 2 – 3TA4N8500 for 3-pole or 2 – 2TA4N8500 for 2-pole. Rated for 75°C cable. Note: A, page 6-81. 햸 80% rated breakers with the CE mark will also be marked in the 100% rated version. 햹 HACR rated. Note: ND frame qualified to UL489 supplement B “NAVAL”. See page 6-84 for additional information. 햷 See Modifications page 6-84 Enclosures Section 5 Accessories pages 6-58 and 6-86 to 6-91 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-55 MOLDED CASE CIRCUIT BREAKERS ND6, NXD6 HND6, HNXD6 CND6 IEC 947-2 Volts AC (50/60HZ) Complete Breaker Unassembled with Lugs Prices of ND6 and HND6 breakers include frame, trip, and both line and load lugs (3TA4N8500). These catalog numbers are the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of NXD6, HNXD6, and CND6 include frame with non-interchangeable trip units installed only. Order required terminal connectors separately. For line and load lugs (3TA4N8500) installed, add suffix “L” to catalog number (add 2 times list price of lug kit). 100% Rated햸 Types NXD6, HNXD6 and CND6 breakers are available with 100% ratings. To order, add suffix “H” to catalog number, and add 10% to list price. 100% rated ND breakers require 90°C Cu cable sized at 75°C ampacity and lug kit 3TA4P8500 or 3TA3N8750. 50°C Applications see page 6-84. 400Hz Applications see page 6-84. 6 Breaker Type RMS Symmetrical Amperes (KA) UL 489 A IR Volts AC Volts DC Ordering Information Molded Case Circuit Breakers ND 1200A Frame Sentron Series Selection/Dimensions Type HNXD6 Black Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) 2-Pole 3-Pole Continuous Current Rating @ 40°C 600V AC/250V DC 600V AC/500V DC 0900 1000 1200 For 2-pole application use outside poles of 3-pole circuit breaker Catalog Number List Price $ HNXD63B900 HNXD63B100 HNXD63B120 14794.00 14794.00 14794.00 Type HND6 Black Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Frame Only Catalog Number Catalog Number List Price $ Trip Unit Only List Price $ Catalog Number List Price $ 2-Pole 600V AC, 250V DC 0800 0900 1000 1200 For 2-pole application use outside poles of 3-pole circuit breaker 3-Pole 600V AC, 500V DC 0800 0900 1000 1200 HND63B800 HND63B900 HND63B100 HND63B120 13883.00 16498.00 16498.00 16498.00 HND63F120 8430.00 MD63T800 ND63T900 ND63T100 ND63T120 MOLDED CASE CIRCUIT BREAKERS 6 Type CND6 3747.00 6362.00 6362.00 6362.00 Red Label Fuseless Current Limiting Non-Interchangeable Trip (Assembled Circuit Breaker) Continuous Current Rating @ 40°C 0900 1000 1200 2-Pole Catalog Number For 2-pole application, use outside poles of 3-pole circuit breaker Lugs 3-Pole CND63B900■ CND63B100 CND63B120 List Price $ 20489.00 20489.00 20489.00 Shipping Weights When lugs shield NDTS is used. Note: NDTS lug shields are required when oversized lugs TA4P8500 or TA4N8500 are used. The kits include the NDTS shield. Dimensions (in inches) Number of Number per Shipping Poles Carton Weight (lbs.) ND6, HND6, NXD6, HNXD6, CND6 Assembled Breaker (less terminals) 2 1 53 3 1 61.5 ND6, HND6 Frame Only 2 1 42.25 3 1 46 ND6, HND6 Trip Unit Only 2 1 04.5 3 1 06.5 Breaker Type W L D D1 ND6, NXD6, HND6, HNXD6, CND6, SND6, SHND6, and SCND6 9 16 6 8.25 with NDTS lug shield 9 24 6 8.25 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. HNXD6 and CND6 circuit breakers are UL Listed for reverse connection applications. 2-pole units available in 3-pole width only. 6-56 When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. HACR rated. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series햳 Selection Current Limiting Type SND6 Type SCND6 Type SHND6 Blue Label Black Label Red Label 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC Catalog Number Max List Current Price Rating $ Catalog Number Max List Current Price Rating $ Catalog Number Max List Current Price Rating $ SND69800A■ SND69100A■ SND69120A■ 800 1000 1200 13569.00 13569.00 13569.00 SHND69800A■ SHND69100A■ SHND69120A■ 800 1000 1200 15151.00 15151.00 15151.00 SCND69800A■ SCND69100A■ SCND69120A■ 800 1000 1200 20855.00 20855.00 20855.00 SND69800AG■ SND69100AG■ SND69120AG■ 800 1000 1200 15272.00 15272.00 15272.00 SHND69800AG■ SHND69100AG■ SHND69120AG■ 800 1000 1200 16733.00 16733.00 16733.00 SCND69800AG■ SCND69100AG■ SCND69120AG■ 800 1000 1200 22969.00 22969.00 22969.00 SND69800ANT■ SND69100ANT■ SND69120ANT■ 800 1000 1200 14192.00 14192.00 14192.00 SHND69800ANT■ SHND69100ANT■ SHND69120ANT■ 800 1000 1200 15772.00 15772.00 15772.00 SCND69800ANT■ 800 SCND69100ANT■ 1000 SCND69120ANT■ 1200 21700.00 21700.00 21700.00 17120.00 17120.00 17120.00 SHND69800ANGT■ 800 SHND69100ANGT■ 1000 SHND69120ANGT■ 1200 18738.00 18738.00 18738.00 SCND69800ANGT■ 800 SCND69100ANGT■ 1000 SCND69120ANGT■ 1200 25762.00 25762.00 25762.00 SND69800ANGT■ 800 SND69100ANGT■ 1000 SND69120ANGT■ 1200 SND 1200A Frame – 100% Rated 햲 Current Limiting Type SND6-H Type SCND6-H Type SHND6H Blue Label Black Label 3-Pole, 600V AC Red Label 3-Pole, 600V AC 3-Pole, 600V AC Catalog Number Max List Current Price Rating $ Catalog Number Max List Current Price Rating $ SND69800AH■ SND69100AH■ SND69120AH■ 800 1000 1200 14955.00 14955.00 14955.00 SHND69800AH■ SHND69100AH■ SHND69120AH■ 800 1000 1200 16657.00 16657.00 16657.00 SCND69800AH■ SCND69100AH■ SCND69120AH■ 800 1000 1200 24085.00 24085.00 24085.00 SND69800AGH■ SND69100AGH■ SND69120AGH■ 800 1000 1200 16766.00 16766.00 16766.00 SHND69800AGH■ SHND69100AGH■ SHND69120AGH■ 800 1000 1200 18418.00 18418.00 18418.00 SCND69800AGH■ SCND69100AGH■ SCND69120AGH■ 800 1000 1200 26551.00 26551.00 26551.00 SND69800ANTH■ SND69100ANTH■ SND69120ANTH■ 800 1000 1200 15628.00 15628.00 15628.00 SHND69800ANTH■ SHND69100ANTH■ SHND69120ANTH■ 800 1000 1200 17335.00 17335.00 17335.00 SCND69800ANTH■ SCND69100ANTH■ SCND69120ANTH■ 800 1000 1200 25060.00 25060.00 25060.00 SND69800ANGTH■ 800 SND69100ANGTH■ 1000 SND69120ANGTH■ 1200 18826.00 18826.00 18826.00 SHND69800ANGTH■ 800 SHND69100ANGTH■ 1000 SHND69120ANGTH■ 1200 20620.00 20620.00 20620.00 SCND69800ANGTH■ 800 SCND69100ANGTH■ 1000 SCND69120ANGTH■ 1200 29750.00 29750.00 29750.00 MOLDED CASE CIRCUIT BREAKERS Max List Current Price Rating $ 6 Catalog Number Trip Unit Adjustable Functions Suffix Letter Code Short Time Pick Up Short Time Delay Short Time l2t Pick Up ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Trip Type Cont Current Setting Long Time Delay Instantaneous Setting A LI ⻫ ⻫ ⻫ AG LIG ⻫ ⻫ ⻫ ANT LSI ⻫ ⻫ ANGT LSIG ⻫ ⻫ Ground Fault Pick Up Ground Fault Delay ⻫ ⻫ ⻫ ⻫ Neutral Transformers Interrupting Ratings Breaker Type RMS Symmetrical kA UL 489 (File E10848) 240V AC 480V AC 600V AC SND6 SHND6 SCND6 065 100 200 050 065 100 25 50 65 Ampere Rating Catalog Number List Price $ 0800 1000 1200 N08SMDA N10SNDA N12SNDA 423.00 423.00 423.00 For inches / millimeters conversion, see Application Data section. For ordering information and terminal connectors, and enclosures, see page 6-55. Note: “G” suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. Discount Schedule MCCB ■ Built to order. Allow 2–3 weeks for delivery. 햲 햳 Use 2-3TA4P8500 for 3-pole. These kits are rated for 90°C wire. 90°C Cu only cable must be used, and sized per 75°C ampacity. SND6, SHND6 and SCND6 circuit breakers are UL Listed for reverse connection applications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-57 Molded Case Circuit Breakers Internal Accessories Accessories for: MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame Selection Shunt Trip Combinations 1 Shunt Trip and 1 Auxiliary Switch Control Voltage 1 Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ S01MN6 S02MN6▲ S03MN6 S15MN6▲ S04MN6▲ S06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 S01MN64A — S03MN64A▲ S15MN64A▲ S04MN64A▲ — 636.00 — 897.00 897.00 897.00 — S16MN6▲ S07MN6 S09MN6▲ S11MN6 S13MN6▲ 636.00 636.00 636.00 636.00 636.00 S16MN64A▲ S07MN64A — S11MN64A▲ S13MN64A▲ 897.00 897.00 — 897.00 897.00 DC 120 208 240 277 480 600 012 024 048 125 250 Undervoltage Trip Combinations Control Voltage AC 1 Undervoltage Trip DC 120 208 240 277 480 600 Sensitrip Ammeter MOLDED CASE CIRCUIT BREAKERS 6 Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole. 024 048 125 250 1 Undervoltage Trip and 1 Auxiliary Switch 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ U01MN6 U02MN6▲ U03MN6▲ U15MN6▲ U04MN6▲ U06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 U01MN64A U02MN64A▲ U03MN64A▲ U15MN64A▲ U04MN64A▲ — 897.00 897.00 897.00 897.00 897.00 —-- U01MN64AA U02MN64AA▲ U03MN64AA▲ U15MN64AA▲ U04MN64AA▲ — 1157.00 1157.00 1157.00 1157.00 1157.00 —--- U07MN6 U09MN6▲ U11MN6▲ U13MN6▲ 636.00 636.00 636.00 636.00 U07MN64A U09MN64A▲ U11MN64A▲ U13MN64A▲ 897.00 897.00 897.00 897.00 U07MN64AA U09MN64AA▲ U11MN64AA▲ U13MN64AA▲ 1157.00 1157.00 1157.00 1157.00 Auxiliary Switch Combinations Maximum Voltage 1 Form C AC DC Catalog Number List Price $ Catalog Number 2 Form C 480 250 A01MN64 271.00 A02MN64 540.00 — 12 A01MNDLV▲ 342.00 A02MNDLV▲ 684.00 List Price $ Alarm Switch Combinations Maximum Voltage The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phase current flowing in the breaker. They are powered by the breaker’s CT’s with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status. 1 Alarm Switch and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch and 2 Auxiliary Switches AC DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 480 250 B00MN64 540.00 271.00 A01MN64B A02MN64B 802.00 Plug-in Ammeter Display Units Breaker Type SMD, SND, SPD Description Catalog Number List Price $ Display Unit SADU 1776.00 Remote Mounting Kit SADURMK18 342.00 Ammeter Mounting Kit The Ammeter may also be panel or door mounted using the SADURMK18 remote mounting kit. ▲ Built to order. Allow 6–8 weeks for delivery. 6-58 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers PD 1600A Frame Sentron Series Selection Type PXD6 Non-Interchangeable Trip Blue Label 3-Pole 600V AC, 250-500V DC Continuous Current Rating 40˚C 1200 1400 1600 Complete Breaker Assembled (Frame/Trip Unit Only) Mounting Assembly Catalog Number PXD63B120■ PXD63B140■ PXD63B160 Catalog Number List Price $ MB9301 -or1227.00 MBR9302 List Price $ 16870.00 16870.00 16870.00 Lugs (6 required) Catalog Number List Price $ TA5P600 320.00 Type PD6 Interchangeable Trip Blue Label 3-Pole 600V AC, 250-500V DC Continuous Current Rating 40°C 1200 1400 1600 Complete Breaker Unassembled Frame Only Catalog Number Catalog Number List Price $ Trip Unit Only List Catalog Price $ Number PD63B120■ 20017.00 PD63B140 20017.00 PD63F160 PD63B160 20017.00 Mounting Assembly List Price $ Catalog Number Lugs (6 required) List Catalog Price $ Number List Price $ PD63T120■ 8199.00 MB9301 8671.00 PD63T140 8199.00 -or1227.00 TA5P600 PD63T160 8199.00 MBR9302 320.00 Type HPXD6 Non-Interchangeable Trip Blue Label 3-Pole 600V AC, 250-500V DC Continuous Current Rating 40°C Complete Breaker Assembled (Frame/ Trip Unit Only) Catalog Number List Price $ 19029.00 HPXD63B120■ 19029.00 HPXD63B140■ HPXD63B160 19029.00 1200 1400 1600 Type HPD6 Interchangeable Trip Black Label 3-Pole 600V AC, 250-500V DC Catalog Number List Price $ Trip Unit Only List Catalog Price $ Number HPD63B120■ 22174.00 HPD63B140 22174.00 HPD63F160 HPD63B160 22174.00 List Price $ Catalog Number Lugs (6 required) List Catalog Price $ Number List Price $ PD63T120■ 8199.00 MB9301 10828.00 PD63T140 8199.00 -or1227.00 TA5P600 PD63T160 8199.00 MBR9302 320.00 Type CPD6 Non-Interchangeable Trip Fuseless Current Limiting 3-Pole 600V AC, 250-500V DC Red Label Complete Breaker Assembled (Frame/ Trip Unit Only) Catalog Number List Price $ 21310.00 CPD63B120■ 21310.00 CPD63B140■ 21310.00 CPD63B160■ Continuous Current Rating 40°C 1200 1400 1600 Lugs Catalog Number TA5P600 TC5R600 TA4P750▲ TA6R600 No of Cables per Connector 1-5 Pcs. 1-5 Pcs. 1-4 Pcs. 1-6 Pcs. Wire Range 300-600 kcmil Cu/Al 300-600 kcmil Cu only 500-750 kcmil Cu/Al 300-600 kcmil Cu/Al List Price $ 320.00 426.00 254.00 338.00 Interrupting Ratings Breaker Type PD6, PXD6 UL 489 A IR IEC 947-2 RMS Symmetrical KA Volts AC (50/60HZ) Volts AC 240 480 600 Volts DC 220/240 250 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs) 500 380/415 500 65 50 25 30 (2P) 25 (3P) 65 33 40 10 30 8 HPD6, HPXD6 100 65 50 30 (2P) 50 (3P) 100 50 65 17 42 11 CPD6 200 100 65 30 (2P) 50 (3P) 200 100 100 25 65 17 ■ Built to order. Allow 2–3 weeks for delivery. ▲ Built to order. Allow 6–8 weeks for delivery. Use two outside poles of a 3-pole circuit breaker for 250V wired as shown on page 6-3, this circuit breaker is When Discount Schedule MCCB UL listed and rated for use on 500V DC ungrounded UPS systems only. HPXD6 and CPD6 type circuit breakers are UL Listed for reverse feed applications. For additional information See Note: A, page 6-81. PXD6, HACR rated. Note: PD frame qualified to UL489 supplement B “NAVAL”. See page 6-84 for additional information. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-59 MOLDED CASE CIRCUIT BREAKERS 1200 1400 1600 Frame Only Catalog Number Mounting Assembly Complete Breaker Unassembled with Lugs Prices of PD6, HPD6, RD6, and HRD6 type breakers include frame, trip, mounting base (MB9301), and both line and load lugs (PD Frame – TA5P600, RD Frame – TC5R600). When ordered by these catalog numbers, the customer will receive the frame, trip, mounting assembly and lugs separately packaged. For applications requiring different mounting base or lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of PXD6, HPXD6, RXD6, HRXD6 and CPD6 type breakers include frame with non-interchangeable trip unit installed only. Order required mounting base and lugs separately. 100% Rated Types PXD6, HPXD6 breakers are available with 100% ratings. To order add suffix “H” to catalog number, and 10% to list price. 100% PD breakers require 90˚ C cable sized at 75˚ C ampacity and TC5R600 lugs. RD 2000A Frames not available with 100% ratings. 50°C Applications see page 6-84. 400HZ Applications see page 6-84. 6 Continuous Current Rating 40°C Complete Breaker Unassembled Ordering Instructions Molded Case Circuit Breakers SPD 1600A Frame Digital Solid State Sentron Sensitrip III Series Selection/Dimensions Ordering Information Pricing information for all Digital Sentron Series PD frame unit is for breaker only. Price required mounting block assembly and necessary terminal connectors as separate items. SPD6 and SHPD6 are acceptable for reverse connection applications. Type SPD6 Type SHPD6 Blue Label Black Label 3-Pole, 600V AC Catalog Number Max Current Rating List Price $ Catalog Number Max Current Rating List Price $ SPD69140■ SPD69160■ 1400 1600 20564.00 20564.00 SHPD69140■ SHPD69160■ 1400 1600 21211.00 21211.00 SPD69140G■ SPD69160G■ 1400 1600 22340.00 22340.00 SHPD69140G■ SHPD69160G■ 1400 1600 23206.00 23206.00 SPD69140NT■ SPD69160NT■ 1400 1600 20903.00 20903.00 SHPD69140NT■ SHPD69160NT■ 1400 1600 21972.00 21972.00 SPD69140NGT■ SPD69160NGT■ 1400 1600 24776.00 24776.00 SHPD69140NGT■ SHPD69160NGT■ 1400 1600 25709.00 25709.00 Short Time Pick Up Short Time Delay Short Time l2t Pick Up ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Suffix Letter Code Trip Type Cont Current Setting Long Time Delay Instantaneous Setting None LI ⻫ ⻫ ⻫ G LIG ⻫ ⻫ ⻫ NT LSI ⻫ ⻫ NGT LSIG ⻫ ⻫ Lugs햲 No. of Catalog Cables per Wire Number Connector Range TA5P600 1–5 pcs. TC5R600 1–5 pcs. TA6R600 1–5 pcs. List Price $ 300–600 kcmil Cu/Al 320.00 300–600 kcmil Cu Only 426.00 300–600 kcmil Cu/Al 338.00 Neutral Transformers Ampere Rating Catalog Number List Price $ 1400 1600 N14SPD N16SPD 423.00 423.00 Type Catalog Number List Price $ 1 PRD6N1 6324.00 Ground Fault Pick Up Ground Fault Delay ⻫ ⻫ Enclosure ⻫ ⻫ Interrupting Ratings Mounting Block (Required)햲 RMS Symmetrical kA UL 489 Breaker Type SPD6 SHPD6 240V AC 480V AC 600V AC Catalog Number 065 100 050 065 025 050 MB9301 MBR9302 List Price $ 1227.00 1227.00 All PD, RD Frames: 6.19 6.00 2.00 MB9301 (shown) MBR9302 25.50 18.73 MBR9302 16.00 2.00 16.00 MOLDED CASE CIRCUIT BREAKERS 6 3-Pole, 600V AC MB9301 MBR9302 MB9301 For inches / millimeters conversion, see Application Data section. ■ Built to order. Allow 2–3 weeks for delivery. 햲 For additional information, see Note: A, page 6-81. Note: The PD frame circuit breaker requires the use of a connect-all mounting assembly to allow for placing into service. 6-60 Note: “G” suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories Accessories for: MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame Selection Shunt Trip Combinations 1 Shunt Trip and 1 Auxiliary Switch Control Voltage 1 Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ S01MN6 S02MN6▲ S03MN6 S15MN6▲ S04MN6▲ S06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 S01MN64A — S03MN64A▲ S15MN64A▲ S04MN64A▲ — 897.00 — 897.00 897.00 897.00 — S16MN6▲ S07MN6 S09MN6▲ S11MN6 S13MN6▲ 636.00 636.00 636.00 636.00 636.00 S16MN64A▲ S07MN64A — S11MN64A▲ S13MN64A▲ 897.00 897.00 — 897.00 897.00 DC 120 208 240 277 480 600 012 024 048 125 250 Undervoltage Trip Combinations Control Voltage AC 1 Undervoltage Trip DC Catalog Number 120 208 240 277 480 600 Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole. 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number List Price $ Catalog Number List Price $ U01MN6 U02MN6▲ U03MN6▲ U15MN6▲ U04MN6▲ U06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 U01MN64A U02MN64A▲ U03MN64A▲ U15MN64A▲ U04MN64A▲ — 897.00 897.00 897.00 897.00 897.00 — U01MN64AA U02MN64AA▲ U03MN64AA▲ U15MN64AA▲ U04MN64AA▲ — 1157.00 1157.00 1157.00 1157.00 1157.00 — U07MN6 U09MN6▲ U11MN6▲ U13MN6▲ 636.00 636.00 636.00 636.00 U07MN64A U09MN64A▲ U11MN64A▲ U13MN64A▲ 897.00 897.00 897.00 897.00 U07MN64AA U09MN64AA▲ U11MN64AA▲ U13MN64AA▲ 1157.00 1157.00 1157.00 1157.00 Auxiliary Switch Combinations 1 Form C AC DC Catalog Number List Price $ Catalog Number 2 Form C 480 250 A01MN64 271.00 A02MN64 540.00 — 12 A01MNDLV▲ 342.00 A02MNDLV▲ 684.00 List Price $ Alarm Switch Combinations Maximum Voltage The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phase current flowing in the breaker. They are powered by the breaker’s CT’s with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status. 1 Alarm Switch and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch and 2 Auxiliary Switches AC DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 480 250 B00MN64 540.00 271.00 A01MN64B A02MN64B 802.00 Plug-in Ammeter Display Units Breaker Type SMD, SND, SPD Description Catalog Number List Price $ Display Unit SADU 1776.00 Remote Mounting Kit SADURMK18 342.00 Ammeter Mounting Kit The Ammeter may also be panel or door mounted using the SADURMK18 remote mounting kit. ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-61 MOLDED CASE CIRCUIT BREAKERS Maximum Voltage 6 Sensitrip Ammeter 024 048 125 250 List Price $ 1 Undervoltage Trip and 1 Auxiliary Switch Molded Case Circuit Breakers RD 2000A Frame Sentron Series Selection Type RXD6 Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker Only Without Lugs) 3-Pole 600V AC, 250-500V DC Continuous Current Rating 40°C 1600 1800 2000 Complete Breaker Assembled (Frame/Trip Unit Only) Mounting Assembly Catalog Number List Price $ Catalog Number List Price $ RXD63B160 RXD63B180 RXD63B200 18701.00 18701.00 18701.00 MB9301 -orMBR9302 1227.00 Lugs (6 required) Catalog Number List Price $ TC5R600 426.00 1227.00 Type RD6 Blue Label Interchangeable Trip (Unassembled Circuit Breaker with Lugs) 3-Pole 600V AC, 250-500V DC Continuous Current Rating 40°C Frame Only Catalog Number Catalog Number List Price $ RD63B160■ 22484.00 RD63B180 22484.00 RD63B200 22484.00 1600 1800 2000 Mounting Block Complete Breaker Unassembled with Lugs List Price $ Trip Unit Only Mounting Assembly Catalog Number Catalog Number List Price $ Lugs (6 required) List Catalog List Price $ Number Price $ RD63T160■ 8927.00 MB9301 1227.00 RD63F200 9774.00 RD63T180 8927.00 -orTC5R600 426.00 RD63T200 8927.00 MBR9302 1227.00 MOLDED CASE CIRCUIT BREAKERS 6 Type HRXD6 Black Label Continuous Current Rating 40°C Complete Breaker Assembled (Frame/ Trip Unit Only) Catalog Number List Price $ 1600 1800 2000 HRXD63B160■ HRXD63B180■ HRXD63B200 21025.00 21025.00 21025.00 Black Label Type HRD6 Complete Breaker Unassembled Continuous with Lugs Current Catalog List Rating 40°C Number Price $ 1600 1800 2000 Frame Only Catalog Number Mounting Assembly Trip Unit Only List Price $ Catalog Number List Catalog Price $ Number Catalog Number Connection Points MB9301 MBR9302 Front Rear List Price $ 1227.00 1227.00 Shipping Weights Number of Number per Poles Carton PXD6, HPXD6, RXD6, HRXD6, Assembled Breakers 3 1 PD6, HPD6, RD6, HRD6 Frame Only 3 1 PD6, RD6 Trip Unit Only 3 1 Mounting Assembly MB9301 1 MBR9302 1 Shipping Weight (lbs.) CPD6 61.5 55.0 06.5 53.0 50.9 Lugs Lugs (6 required) List Catalog List Price $ Number Price $ HRD63B160■ 24808.00 RD63T160■ 8927.00 MB9301 1227.00 HRD63B180 24808.00 HRD63F200 12098.00 RD63T180 8927.00 -orTC5R600 426.00 HRD63B200 24808.00 RD63T200 8927.00 MBR9302 1227.00 Catalog Number No of Cables per Connector Wire Range TA5P600 TC5R600 TA4P750▲ TA6R600 1-5 1-5 1-4 1-6 Pcs. Pcs. Pcs. Pcs. 300-600 300-600 500-750 300-600 kcmil kcmil kcmil kcmil List Price $ Cu/Al Cu only Cu/Al Cu/Al 320.00 426.00 254.00 338.00 Interrupting Ratings UL 489 A IR IEC 947-2 RMS Symmetrical KA Volts AC (50/60HZ) Volts AC Breaker Type 240 RD6, RXD6 HRD6, HRXD6 480 600 Volts DC 220/240 250 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs) 500 380/415 500 65 50 25 30 (2P) 25 (3P) 65 33 40 10 30 8 100 65 50 30 (2P) 50 (3P) 100 50 65 17 42 11 Instantaneous Adjustment Trip Range (PD / RD Frames) Breaker Ampere Rating 1200-2000 Nominal Instantaneous Values +20% Tolerance Low 2 3 4 5000 5715 6430 7145 ■ Built to order. Allow 2–3 weeks for delivery. ▲ Built to order. Allow 6–8 weeks for delivery. Use two outside poles of a 3-pole circuit breaker for 250V DC applications. 6-62 5 7860 6 8575 7 9790 +20% Tolerance High 10,000 When wired as shown on page 6-3, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. RXD6 and HRXD6 type circuit breakers are UL Listed for reverse feed applications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog HACR rated. For additional information See Note: A, page 6-81. Note: RD frame qualified to UL489 supplement B “NAVAL”. See page 6-84 for additional information. Note: For required mounting base (MB9301 or MBR9302) see page 6-60. Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories Accessories for: MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame Selection Shunt Trip Combinations 1 Shunt Trip and 1 Auxiliary Switch Control Voltage 1 Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ S01MN6 S02MN6▲ S03MN6 S15MN6▲ S04MN6▲ S06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 S01MN64A — S03MN64A▲ S15MN64A▲ S04MN64A▲ — 897.00 — 897.00 897.00 897.00 — S16MN6▲ S07MN6 S09MN6▲ S11MN6 S13MN6▲ 636.00 636.00 636.00 636.00 636.00 S16MN64A▲ S07MN64A — S11MN64A▲ S13MN64A▲ 897.00 897.00 — 897.00 897.00 DC 120 208 240 277 480 600 012 024 048 125 250 Undervoltage Trip Combinations Control Voltage AC 1 Undervoltage Trip DC Catalog Number 120 208 240 277 480 600 Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole. 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number Catalog Number List Price $ U01MN6 U02MN6▲ U03MN6▲ U15MN6▲ U04MN6▲ U06MN6▲ 636.00 636.00 636.00 636.00 636.00 636.00 U01MN64A U02MN64A▲ U03MN64A▲ U15MN64A▲ U04MN64A▲ — List Price $ 897.00 897.00 897.00 897.00 897.00 — U01MN64AA U02MN64AA▲ U03MN64AA▲ U15MN64AA▲ U04MN64AA▲ — 1157.00 1157.00 1157.00 1157.00 1157.00 — U07MN6 U09MN6▲ U11MN6▲ U13MN6▲ 636.00 636.00 636.00 636.00 U07MN64A U09MN64A▲ U11MN64A▲ U13MN64A▲ 897.00 897.00 897.00 897.00 U07MN64AA U09MN64AA▲ U11MN64AA▲ U13MN64AA▲ 1157.00 1157.00 1157.00 1157.00 Auxiliary Switch Combinations 1 Form C AC DC Catalog Number List Price $ Catalog Number 2 Form C 480 250 A01MN64 271.00 A02MN64 540.00 — 12 A01MNDLV▲ 342.00 A02MNDLV▲ 684.00 List Price $ Alarm Switch Combinations The Ammeter Display Units plug into the Sensitrip Trip Unit and displays the phase current flowing in the breaker. They are powered by the breaker’s CT’s with replaceable battery back-up for maintaining trip and max logs. The SADU reads currents, current imbalance, current demand, and trip status. Maximum Voltage 1 Alarm Switch 1 Alarm Switch and 1 Auxiliary Switch AC DC Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 480 250 B00MN64 540.00 271.00 A01MN64B 1 Alarm Switch and 2 Auxiliary Switches A02MN64B 802.00 Plug-in Ammeter Display Units Breaker Type SMD, SND, SPD Description Catalog Number List Price $ Display Unit SADU 1776.00 Remote Mounting Kit SADURMK18 342.00 Ammeter Mounting Kit The Ammeter may also be panel or door mounted using the SADURMK18 remote mounting kit. ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-63 MOLDED CASE CIRCUIT BREAKERS Maximum Voltage 6 Sensitrip Ammeter 024 048 125 250 List Price $ 1 Undervoltage Trip and 1 Auxiliary Switch Molded Case Circuit Breakers STD 3200A Frame Digital Solid State Sentron Sensitrip III Series Type STD6 Type SHTD6 Blue Label Black Label 3-Pole, 600V AC, 80% Rated Catalog Number STD63F2000■ STD63F2500■ STD63F3200■ 2000 2500 3200 SHTD63F2000■ 2000 SHTD63F2500■ 2500 SHTD63F3200■ 3200 24668.00 27714.00 30485.00 3-Pole, 600V AC, 100% Rated Max List Current Price Rating $ STD63F2000H■ 2000 STD63F2500H■ 2500 STD63F3200H■ 3200 27132.00 30485.00 33533.00 3-Pole, 600V AC, 80% Rated Max List Current Price Rating $ Max List Current Price Rating $ Catalog Number STD Breakers are ordered by component - Frame, Trip Unit & Rating Plug, Accessories. Contact Sales Office for instructions. 29847.00 33533.00 36884.00 3-Pole, 600V AC, 100% Rated Max List Current Price Rating $ SHTD63F2000H■ 2000 SHTD63F2500H■ 2500 SHTD63F3200H■ 3200 Max List Current Price Rating $ SHHTD63F2000■ 2000 SHHTD63F2500■ 2500 SHHTD63F3200■ 3200 27132.00 30485.00 33533.00 3-Pole, 600V AC, 100% Rated Catalog Number Ordering Information Red Label 3-Pole, 600V AC, 80% Rated Catalog Number Catalog Number Type SHHTD6 Selection/Dimensions Catalog Number Max List Current Price Rating $ SHHTD63F2000H■ 2000 SHHTD63F2500H■ 2500 SHHTD63F3200H■ 3200 29847.00 36884.00 40573.00 H H1 32828.00 40573.00 44630.00 Trip Unit Fits Breaker Frame with Continuous Rating 2000 Amp 2500 Amp 3200 Amp List Price $ STD20TLS■ STD25TLS■ STD32TLS■ 2260.00 STD20TLI■ STD20TLSI■ STD25TLI■ STD25TLSI■ STD32TLI■ STD32TLSI■ 1611.00 Breaker Type H H1 W D 2938.00 STD20TLSG■ STD20TLIG■ STD25TLSG■ STD25TLIG■ STD32TLSG■ STD32TLIG■ 4260.00 27.5 20.5 15.5 12.5 LIG STD SHTD SHHTD LSIG STD20TLSIG■ STD25TLSIG■ STD32TLSIG■ 4981.00 Function Catalog Numbers LS LI LSI LSG 2835.00 MOLDED CASE CIRCUIT BREAKERS 6 Rating Plug Fits Breaker Frame with Continuous Rating Long Time Amperes 2000 Amp 2500 Amp 3200 Amp 1000 20STD1000■ 1200 20STD1200■ 1600 20STD1600■ 25STD1600■ 32STD1600■ 2000 20STD2000■ 25STD2000■ 25STD2500■ 32STD2000■ Catalog Numbers List Price $ 352.00 32STD2500■ 3000 32STD3000■ 3200 32STD3200■ STD6 SHTD6 SHHTD6 RMS Symmetrical kA UL 489 (File E 10848) 085 150 200 Dimensions (in Inches)햲 Terminal Connectors Catalog Number List Price $ STD32TCON 224.00 Cable Lugs 480V AC 065 100 150 600V AC 050 085 100 IEC60947-2 (Icu=Ics, Icw=50kA) 415VAC — 100kA — Catalog Number TA6R600STD No of Cables per Con- Wire nector Range (1–6 pcs.) 250-600 kcmil Cu/Al List Price $ 323.00 Neutral Transformers Interrupting Ratings 240V AC D (2000A Only) 2500 Breaker Type W 690VAC — 65kA — Ampere Rating Catalog Number List Price $ 2000 2500 3200 N20STD N25STD N32STD 460.00 460.00 460.00 Accessories pages 6-65 and 6-84 to 6-91 ■ Built to order. Allow 2–3 weeks for delivery. 햲 Dimensions 6-64 for reference, not for construction. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Internal Accessories Selection Accessories for: Shunt Trip / Undervoltage Release STD 3200A Frame STD Breakers are built to order. It is recommended that accessories be ordered installed in the breaker. They may also be field added. Control Voltage Shunt Trip AC Catalog Number List Price $ Catalog Number List Price $ STDST120▲ STDST240▲ STDST480▲ — 776.00 776.00 776.00 — STDUV120▲ STDUV240▲ STDUV480▲ STDUV600▲ 776.00 776.00 776.00 776.00 STDST12▲ STDST24▲ STDST48▲ STDST125▲ 776.00 776.00 776.00 776.00 — STDUV24▲ STDUV48▲ STDUV125▲ — 776.00 776.00 776.00 120 240 480 600 012 024 048 125 Ammeter Display Module The STDDM plugs into the trip unit of the STD 3200 Amp breaker. It provides readout of currents as well as load current alarm (in conjunction with the display module relay). Ground Fault Monitor The Ground Fault Monitor for the STD 3200 Amp breaker family plugs into the Trip Unit and reads the ground current. This is either the residual current calculated from the measured three phases and neutral (if present) or the directly measured ground return current in the ground lead of the supply transformer, depending on the configuration of the the trip unit. In addition to displaying the ground current, the display module provides an alarm on ground overcurrent, settable at three pickup levels with three delays (in conjunction with the display module relay). DC Under Voltage Release Auxiliary Switches Control Voltage Quantity Contacts AC NO NC Catalog Number List Price $ 1 2 3 4 5 6 1 2 3 4 5 6 STDAS2▲ STDAS4▲ STDAS6▲ STDAS8▲ STDAS10▲ STDAS12▲ 397.00 653.00 980.00 1308.00 1641.00 1945.00 600 DC 300 Auxiliary Power Module Alarm Switch Control Voltage AC DC Catalog Number List Price $ 600 300 STDAS▲ 768.00 Power Source Catalog Number List Price $ 120V AC STDAPM▲ 718.00 Electronic Bell Alarm / Display Relay Bell Alarm AC DC Catalog Number List Price $ Catalog Number List Price $ 24 48 125 STDBA120▲ STDBA24▲ STDBA48▲ STDBA125▲ 776.00 776.00 776.00 776.00 STDDMR120▲ STDDMR24▲ STDDMR48▲ STDDMR125▲ 776.00 776.00 776.00 776.00 120 Display Module Relay Ground Fault Monitor Catalog Number List Price $ Catalog Number List Price $ STDDM▲ 3198.00 STDGFM▲ 4102.00 Mounting Bracket for Terminal Block For mounting Control Terminal Blocks to breakers. One per each side as required. Catalog Number List Price $ STDTBM▲ 98.00 Secondary Terminal Blocks The appropriate number and location of terminal blocks should be selected from the table below based on the features and accessories ordered on each circuit breaker. Control Terminal Blocks also require separate mounting brackets for the left and right sides. Accessory Contact Block Position Catalog Number List Price $ LEFT TOP STDTBLT▲ 162.00 LEFT BOTTOM STDTBLB▲ 162.00 RIGHT TOP STDTBRT▲ 162.00 RIGHT BOTTOM STDTBRB▲ 162.00 Shunt Trip Undervoltage Release Neutral Sensor X X X Zone Interlock and ACCESS Auxiliary Switches Bell Alarm햲 or Display Module Relay 1A and 1B 2A and 2B 3A and 3B 4A and 4B 5A and 5B 6A and 6B X X X X X ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-65 MOLDED CASE CIRCUIT BREAKERS Ammeter-Display Module 6 Control Voltage Molded Case Circuit Breakers Magnetic Trip Only — ETI Motor Circuit Protector Instantaneous Trip Range Breaker Type ED6-A 600V AC 250V DC CED6-A 600V AC 250V DC FXD6 600V AC 250V DC CFD6 MOLDED CASE CIRCUIT BREAKERS 6 600V AC 250V DC JXD6(A) 600V AC 250V DC CJD6 600V AC 250V DC LXD6(A) 600V AC 250V DC CLD6 600V AC 250V DC LMXD6 600V AC 250V DC MXD6 600V AC 250V DC CMD6 600V AC 250V DC Ampere Rating 001 002 003 005 010 025 030 040 050 100 125 SHIPPING: 001 002 003 005 010 025 030 040 050 100 125 SHIPPING: 150 150 150 250 SHIPPING: 150 150 150 250 SHIPPING: 400 400 SHIPPING: 400 400 SHIPPING: 600 600 SHIPPING: 600 600 SHIPPING: 800 800 SHIPPING: 800 800 800 SHIPPING: 800 800 800 Selection Minimum 002.6 007 010 016 030 055 080 115 180 315 500 Maximum 00009 00022 00035 00054 00100 00180 00270 00375 00600 01000 01250 002.6 007 010 016 030 055 080 115 180 315 500 00009 00022 00035 00054 00100 00180 00270 00375 00600 01000 01250 0400 0800 1100 1100 00800 01500 02500 02500 0400 0800 1100 1100 00800 01500 02500 02500 1250 2000 02500 04000 1250 2000 02500 04000 2000 3000 04000 06000 2000 3000 04000 06000 2800 3200 06000 08000 3000 4000 5000 06000 08000 10000 Complete Circuit Breaker Without Lugs Catalog Catalog Number List Number 2-Pole Price $ 3-Pole — — ED63A001 — — ED63A002 — — ED63A003 — — ED63A005 — — ED63A010 — — ED63A025 — — ED63A030 — — ED63A040 — — ED63A050 — — ED63A100 — — ED63A125 03.8 lbs. each — — CED63A001■ — — CED63A001■ — — CED63A003■ — — CED63A005■ — — CED63A010■ — — CED63A025■ — — CED63A030■ — — CED63A040■ — — CED63A050■ — — CED63A100■ — — CED63A125■ 06 lbs. each — — FXD63L150■ — — FXD63A150 — — FXD63H150 — — FXD63A250 0 09 lbs. each — — CFD63L150■ — — CFD63A150■ — — CFD63H150■ — — CFD63A250■ 12 lbs. each 12 lbs. each — — JXD63L400 JXD62H400■ 3077.00 JXD63H400 16 lbs. each 20 lbs. each CJD62L400■ 6222.00 CJD63L400■ CJD62H400■ 6222.00 CJD63H400■ 29.5 lbs. each 31.5 lbs. each LXD62L600■ 4616.00 LXD63L600■ — — LXD63H600 16 lbs. each 20 lbs. each CLD62L600■ 10003.00 CLD63L600■ CLD62H600■ 10003.00 CLD63H600■ 31.5 lbs. each — — LMXD63L800■ — — LMXD63A800 35 lbs. each — — MXD63L800■ — — MXD63A800■ — — MXD63H800 3000 4000 5000 06000 08000 10000 — — — SHIPPING: Important Information ETI interrupting ratings are determined through combination tests with properly sized overload relays and contactors. Connectors included when ordering by circuit breaker catalog number for ED6 and CED6 ETI’s. Order ETI circuit breaker and lugs (2 per pole) separately for the FXD6, CFD6, MXD6, CMD6, JXD6, CJD6, LXD6 and CLD6 ETI’s. ■ Built to order. Allow 2–3 weeks for delivery. 2-pole available in 3-pole width only. 6-66 — — — When applied on DC Circuits — Trip levels will increase approximately +15 to 20%. Tolerance -20/+30% Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 33 lbs. each CMD63L800■ CMD63A800■ CMD63H800■ 80 lbs. each List Price $ 824.00 824.00 824.00 824.00 824.00 824.00 824.00 824.00 991.00 1052.00 1997.00 2811.00 2811.00 2811.00 2811.00 2811.00 2811.00 2811.00 2811.00 3360.00 3608.00 5409.00 3448.00 3448.00 3448.00 3448.00 6664.00 6664.00 6664.00 6664.00 3608.00 3608.00 7742.00 7742.00 5267.00 5267.00 12392.00 12392.00 7460.00 7460.00 7460.00 7460.00 7460.00 14019.00 14019.00 14019.00 Lug Information pages 6-81 to 6-83 Enclosures Section 5 Accessories pages 6-86 to 6-91 Application data pages 6-67 to 6-68 For 2-pole application use outside poles of 3-pole circuit breaker. Discount Schedule MCCB Molded Case Circuit Breakers Motor Circuits Application General Protection of Motor Circuits Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be used in conjunction with motor-running, over-current-protection devices, and should permit the motor to start without nuisance tripping from motor-inrush current. The circuit breaker should have a continuous-current rating of not less than 115% of the motor full-load current. The recommended motor circuit protectors (Siemens ETI instantaneous only circuit breakers) listed have continuous-current ratings of at least 115% of motor full-load currents. The trip-setting positions are approximately 11 times motor full-load currents. The suggested trip settings may have to be adjusted upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full load current for design E motors, to allow for motor start-up due to inrush currents. Breaker Mounted Immediately Ahead of Motor Starter Siemens ETI motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protection for the motor branch circuit. The adjustable instantaneous-trip feature of the Siemens ETI motor circuit protector provides for a trip setting slightly above the peak motor-inrush current. With this setting, no delay is introduced in opening the circuit when a fault occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead of, the motor-running overcurrent protective device. Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National Electrical Code (NEC) for specific needs. Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter) 3-Phase Induction Type Motors (Siemens ETI motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters). Catalog Number ED63A001 CED63A001 ED63A002 CED63A002 ED63A005 CED63A005 ED63A010 CED63A010 ED63A025 CED63A025 ED63A030 CED63A030 ED63A040 CED63A040 ED63A050 CED63A050 ED63A100 CED63A100 Motor Full Load Amperes 38.46 – 55.37 55.38 – 70.75 70.76 – 84.60 84.61 – 96.14 96.15 – 113.60 30.76 – 35.37 35.38 – 39.99 44.51 – 49.23 53.84 – 58.45 58.46 – 63.06 63.07 – 74.50 61.53 – 69.22 69.23 – 76.91 84.61 – 92.29 100.00 – 108.00 108.00 – 115.00 115.00 – 136.00 85.00 – 100.00 100.00 – 115.00 131.00 – 146.00 162.00 – 177.00 177.00 – 192.00 192.00 – 227.00 95.00 – 110.00 110.00 – 124.00 138.00 – 151.00 165.00 – 178.00 178.00 – 192.00 192.00 – 227.00 154.00 – 176.00 176.00 – 198.00 220.00 – 242.00 264.00 – 285.00 285.00 – 308.00 308.00 – 326.00 155.00 – 176.00 176.00 – 198.00 220.00 – 242.00 264.00 – 285.00 285.00 – 308.00 308.00 – 326.00 Catalog Number ED63A125 CED63A125 FXD63L150 CFD63L150 FXD63A150 CFD63A150 FXD63A250 CFD63A250 JXD63L400 CJD63L400 JXD63H400 CJD63H400 LXD63L600 CLD63L600 ETI Trip Adjustment Low 2 3 4 High Low 2 4 6 7 High Low 2 4 6 7 High Low 2 4 6 7 High Low 2 4 6 7 High Low 2 4 6 7 High Low 2 4 6 7 High Setting Amperes 500 720 920 1100 1250 400 460 580 700 760 820 800 900 1100 1300 1400 1500 1100 1300 1700 2100 2300 2500 1250 1430 1790 2140 2320 2500 2000 2290 2860 3430 3710 4000 2000 2290 2860 3430 3710 4000 Motor Full Load Amperes 231.00 – 264.00 264.00 – 292.00 330.00 – 362.00 395.00 – 428.00 428.99 – 462.00 462.00 – 490.00 215.00 – 238.00 238.00 – 261.00 261.00 – 284.00 308.00 – 369.00 369.00 – 423.00 423.00 – 462.00 462.00 – 490.00 246.00 – 269.00 269.00 – 284.00 284.00 – 323.00 362.00 – 492.00 492.00 – 562.00 562.00 – 616.00 616.00 – 660.00 231.00 – 264.00 264.00 – 292.00 292.00 – 330.00 362.00 – 395.00 428.00 – 462.00 462.00 – 490.00 308.00 – 352.00 352.00 – 442.00 442.00 – 447.00 483.00 – 527.00 571.00 – 616.00 616.00 – 660.00 385.00 – 440.00 495.00 – 550.00 605.00 – 660.00 660.00 – 695.00 Catalog Number LXD63H600 CLD63H600 LMXD63L800 LMXD63A800 MXD63L800 CMD63L800 MXD63A800 CMD63A800 MXD63H800 CMD63H800 ETI Trip Adjustment Low 2 4 6 7 High Low 2 3 5 6 7 High Low 2 3 5 6 7 High Low 2 3 5 7 High Low 2 3 5 7 High Low 3 5 6 Setting Amperes 3000 3430 4290 5140 5570 6000 2800 3100 3400 4000 4800 5500 6000 3200 3500 3700 4700 6400 7300 8000 3000 3430 3800 4710 5570 6000 4000 4570 5740 6280 7240 8000 5000 6430 7860 8575 Note: Low instantaneous settings have a +20% tolerance and high settings have a +20% tolerance Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-67 MOLDED CASE CIRCUIT BREAKERS ED63A003 CED63A003 ETI Trip Setting Adjustment Amperes Low 2.6 2 4.5 3 6 4 7.5 High 9 Low 7 2 11 3 15 4 19 High 22 Low 10 2 17 3 23 4 30 High 35 Low 16 2 26 3 36 4 46 High 54 Low 30 2 50 3 70 4 85 High 100 Low 55 2 90 3 125 4 155 High 180 Low 80 2 135 3 185 4 235 High 270 Low 115 2 185 3 255 4 325 High 375 Low 180 2 300 3 410 4 520 High 600 Low 315 2 540 3 740 4 890 High 1000 6 Motor Full Load Amperes .20 – .33 .34 – .45 .46 – .56 .57 – .68 .69 – .81 .53 – .83 .84 – 1.14 1.15 – 1.45 1.46 – 1.68 1.69 – 2.00 .76 – 1.29 1.30 – 1.75 1.76 – 2.29 2.30 – 2.68 2.69 – 3.18 1.23 – 1.99 2.00 – 2.75 2.76 – 3.52 3.53 – 4.14 4.15 – 4.90 2.30 – 3.83 3.84 – 5.37 5.38 – 6.52 6.53 – 7.68 7.69 – 9.10 4.23 – 6.91 6.92 – 9.61 9.62 – 11.91 11.92 – 13.83 13.84 – 16.40 6.15 – 10.37 10.38 – 14.22 14.23 – 18.06 18.07 – 20.75 20.76 – 24.50 8.84 – 14.22 14.23 – 19.60 19.61 – 24.99 25.00 – 28.83 28.84 – 34.00 13.84 – 23.06 23.07 – 31.52 31.53 – 39.99 40.00 – 46.14 46.15 – 54.50 24.23 – 41.52 41.53 – 56.91 56.92 – 68.45 68.46 – 76.91 76.92 – 90.90 Molded Case Circuit Breakers Motor Circuits Application Breaker Mounted at a Distance From Motor Starter ET thermal-magnetic circuit breakers conform to the National Electrical Code table 430-152 requirements for motor branch and feeder circuit protection when properly applied in conjunction with motor-running overcurrent protective devices. The recommended Interrupt Ratings For normal commercial purposes, available fault current can conveniently be obtained in the Interrupting Selector Tables. circuit-breaker ratings in Table 2 provide adequate time delay for starting the majority of three phase induction motors. To determine the ampere ratings of the ET breaker to protect a motor feeder, add the rating of the ET breaker used to protect the largest motor branch circuit in the group to the full-load currents of the remaining motors in the group. Table 2 (When Breaker is Mounted at a Distance From Motor Starter) 3-Phase Induction Type Motors (EQ and ET circuit breakers (thermal-magnetic trip) for branch breaker use with alternating-current combination motor starters). MOLDED CASE CIRCUIT BREAKERS 6 Motor Horsepower Rating 0001⁄2 0003⁄4 001 0011⁄2 002 003 005 0071⁄2 010 015 020 025 030 040 050 060 075 100 200 and 208V Motors 240V Circuit Breaker Data Breaker Catalog Ampere Type Number Rating BQ3B015 015 BQ3B015 015 BQ3B015 015 BQ BQ3B015 015 BQ3B020 020 BQ3B030 030 BQ3B040 040 BQ3B060 060 BQ BQ3B070 070 BQ3B100 100 FXD6 JXD2 JXD2 FXD63B125 FXD63B150 FXD63B175 FXD63B200 FXD63B225 JXD23B300 JXD23B400 125 150 175 200 225 300 400 230V Motors 240V Circuit Breaker Data Breaker Catalog Ampere Type Number Rating BQ3B015 015 BQ3B015 015 BQ3B015 015 BQ BQ3B015 015 BQ3B015 015 BQ3B020 020 BQ3B030 030 BQ3B050 050 BQ BQ3B070 070 BQ3B090 090 BQ3B100 100 FXD63B125 125 FXD63B150 150 FXD6 FXD63B175 175 FXD63B200 200 460V Motors 480V Circuit Breaker Data Breaker Catalog Ampere Type Number Rating ED43B015 015 ED43B015 015 ED43B015 015 ED4 ED43B015 015 ED43B015 015 ED43B015 015 ED43B015 015 ED43B030 030 ED4 ED43B030 030 ED43B040 040 ED43B050 050 FXD63B090 090 FXD63B100 100 FXD6 FXD63B125 125 FXD63B150 150 575V Motors 600V Circuit Breaker Data Breaker Catalog Ampere Type Number Rating ED63B015 015 ED63B015 015 ED63B015 015 ED6 ED63B015 015 ED63B015 015 ED63B015 015 ED63B015 015 ED63B020 020 ED6 ED63B030 030 ED63B035 035 ED63B050 050 FXD63B060 060 FXD63B070 070 FXD6 FXD63B090 090 FDX63B100 100 — JXD2 FXD6, FD6 FXD6, FD6 FD6 JD6 FXD6 FXD63B100 FXD6, FD6 FXD63B125 100 125 FXD6, FD6 FD63B175 175 FXD6, FD6 OR JD6 FXD6 or JD6 JD6 JD6 FXD63B200 JD63B200 FXD63B225 JD63B225 JD63B300 JD63B400 200 200 225 225 300 400 JD6 JD63B400 400 LD6 or LMD6 LD6 or LMD6 LMD6 LD63B500 or LMD63B500 LD63B600 or LMD63B600 LMD63B800 500 — JXD23B350 — 350 400 FXD63B150 FXD63B200 FD63B250 JD63B250 150 200 250 250 JXD2 JXD23B400 400 JXD2 JXD23B400 LD63B600 LMD63B600 LD63B600 or LMD63B600 LMD63B800 — 600 LD6 or LMD6 JD6 JD63B300 300 600 LMD6 600 JD6 JD63B300 300 800 — LMD6 — LD63B500 or LMD63B500 LD63B600 or LMD63B600 LMD63B800 — 500 200 250 LD6 or LMD6 LD6 or LMD6 LMD6 — 800 — — — — — — — JD63B350 JD63B400 LD63B600 or LMD63B600 350 400 300 JD6 JD6 LD6 or LMD6 LMD6 LMD63B700 700 125 150 600 350 — — — — — — 400 — — — — — — LMD6 LMD63B800 800 500 — — — — — — — — — The selection of breakers for this table is in accordance with Article 430, 2005 National Electric Code. Recommended circuit breakers are for full voltage starting, special consideration is necessary for reduced voltage starting. 6-68 For panelboard applications, substitute the BL breaker for the BQ, ED2 circuit breakers may also be used. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog For 600 800 non-interchangeable trip applications, substitute the FXD6 for the FD6, the JXD6 for the JD6, or the LXD6 for the LD6. Molded Case Circuit Breakers Adjustable Installments Magnetic Trip Settings Breaker Type ED6 CED6 FXD6-A HHFD6 CFD6 Trip Range 3 4 6 7.5 15 19 23 30 36 46 70 85 125 155 185 235 255 325 410 520 740 890 920 1100 6 7.5 15 19 23 30 36 46 70 85 125 155 185 235 255 325 410 520 740 890 920 1100 690 730 690 730 690 730 840 920 840 920 1000 1100 520 580 1000 1100 1500 1700 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 1000 1100 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 1000 1100 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 1000 1100 1210 1370 1210 1370 1500 1700 1500 1700 690 730 690 730 690 730 840 920 840 920 1000 1100 520 580 1000 1100 1500 1700 1210 1370 1210 1370 1500 1700 1500 1700 Note: Tolerances for instantaneous trip points meet UL 489 (7.3). Nominal AC instantaneous trip points are given in the tables. For DC instantaneous trip points, add 15% to nominal values. 5 6 7 — — — — — — — — — — — — — — — — — — — — — — 770 770 770 990 990 1200 640 1200 1900 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 640 1200 1900 1520 1520 1900 1900 — — — — — — — — — — — — — — — — — — — — — — 810 810 810 1060 1060 1300 700 1300 2100 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 700 1300 2100 1780 1780 2100 2100 — — — — — — — — — — — — — — — — — — — — — — 850 850 850 1140 1140 1400 760 1400 2300 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 760 1400 2300 1930 1930 2300 2300 High 9 22 35 54 100 180 270 375 600 1000 1250 9 22 35 54 100 180 270 375 600 1000 1250 900 900 900 1200 1200 1500 820 1500 2500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 820 1500 2500 2000 2000 2500 2500 ETI Motor Circuit Protector Catalog Number 3-Pole ED63A001 ED63A002 ED63A003 ED63A005 ED63A010 ED63A025 ED63A030 ED63A040 ED63A050 ED63A100 ED63A125 CED63A001■ CED63A002■ CED63A003■ CED63A005■ CED63A010■ CED63A025■ CED63A030■ CED63A040■ CED63A050 CED63A100 CED63A125 — — — — — — FXD63L150 FXD63A150 FXD63H150 — — — FXD63A250 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — CFD63L150 CFD63A150 CFD63H150 — — — CFD63A250 Instantaneous trip adjustment is made through the breaker cover on all frame breakers. To change instantaneous trip point on circuit breaker, depress indicating knob, then rotate to desired position. Thermal Magnetic Catalog Number 2-Pole 3-Pole — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — FXD62B070 FXD63B070 FXD62B080 FXD63B080 FXD62B090 FXD63B090 FXD62B100 FXD63B100 FXD62B110 FXD63B110 FXD62B125 FXD63B125 — — FXD62B150 FXD63B150 — — FXD62B175 FXD63B175 FXD62B200 FXD63B200 FXD62B225 FXD63B225 FXD62B250 FXD63B250 FD62B070 FD63B070 FD62B080 FD63B080 FD62B090 FD63B090 FD62B100 FD63B100 FD62B110 FD63B110 FD62B125 FD63B125 FD62B150 FD63B150 FD62B175 FD63B175 FD62B200 FD63B200 FD62B225 FD63B225 FD62B250 FD63B250 HFD62B070 HFD63B070 HFD62B080 HFD63B080 HFD62B090 HFD63B090 HFD62B100 HFD63B100 HFD62B110 HFD63B110 HFD62B125 HFD63B125 HFD62B150 HFD63B150 HFD62B175 HFD63B175 HFD62B200 HFD63B200 HFD62B225 HFD63B225 HFD62B250 HFD63B250 — HHFD63B070 — HHFD63B080 — HHFD63B090 — HHFD63B100 — HHFD63B110 — HHFD63B125 — HHFD63B150 — HHFD63B175 — HHFD63B200 — HHFD63B225 — HHFD63B250 CFD62B070 CFD63B070 CFD62B080 CFD63B080 CFD62B090 CFD63B090 CFD62B100 CFD63B100 CFD62B110 CFD63B110 CFD62B125 CFD63B125 — — CFD62B150 CFD63B150 — — CFD62B175 CFD63B175 CFD62B200 CFD63B200 CFD62B225 CFD63B225 CFD62B250 CFD63B250 ■ Built to order. Allow 2–3 weeks for delivery. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-69 MOLDED CASE CIRCUIT BREAKERS HFD6 Nominal AC Adjustable Low 2 2.6 4.5 7 11 10 17 16 26 30 50 55 90 80 135 115 185 180 300 315 540 500 720 2.6 4.5 7 11 10 17 16 26 30 50 55 90 80 135 115 185 180 300 315 540 500 720 600 640 600 640 600 640 700 770 700 770 800 900 400 460 800 900 1100 1300 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 800 900 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 800 900 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 800 900 900 1060 900 1060 1100 1300 1100 1300 600 640 600 640 600 640 700 770 700 770 800 900 400 460 800 900 1100 1300 900 1060 900 1060 1100 1300 1100 1300 6 FD6-A Maximum Continuous Amperes 1 2 3 5 10 25 30 40 50 100 125 1 2 3 5 10 25 30 40 50 100 125 70 80 90 100 110 125 150 150 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 150 150 175 200 225 250 Application Molded Case Circuit Breakers Adjustable Instantaneous Magnetic Trip Settings Breaker Type JXD2(A) JXD6(A) JD6(A) HJD6(A) HHJD6 MOLDED CASE CIRCUIT BREAKERS 6 CJD6 LXD6(A) LD6(A) HLD6(A) HHLD6 CLD6 LMXD6 LMD6 6-70 Maximum Continuous Amperes 200 225 250 300 350 400 200 225 250 300 350 400 200 225 250 300 350 400 400 200 225 250 300 350 400 200 225 250 300 350 400 200 225 250 300 350 400 400 450 500 600 250 300 350 400 450 500 600 600 250 300 350 400 450 500 600 250 300 350 400 450 500 600 250 300 350 400 450 500 600 600 500 600 700 800 800 500 600 700 800 Nominal AC Adjustable Low 2 1250 1430 1250 1430 1250 1430 1250 1430 2000 2290 2000 2290 1250 1430 1250 1430 1250 1430 1250 1430 2000 2290 2000 2290 1250 1430 1250 1430 1250 1430 1250 1430 2000 2290 1250 1430 2000 2290 1250 1430 1250 1430 1250 1430 1250 1430 2000 2290 2000 2290 1250 1430 1250 1430 1250 1430 1250 1430 2000 2290 2000 2290 1250 1430 1250 1430 1250 1430 1250 1430 2000 2290 2000 2290 1250 1450 2000 2290 3000 3430 3000 3430 1250 1430 1250 1430 2000 2290 2000 2290 2000 2290 3000 3430 2000 2290 3000 3430 1250 1430 1250 1430 2000 2290 2000 2290 2000 2290 3000 3430 3000 3430 1250 1430 1250 1430 2000 2290 2000 2290 2000 2290 3000 3430 3000 3430 1250 1430 1250 1430 2000 2290 2000 2290 2000 2290 3000 3430 2000 2290 3000 3430 3000 3430 3000 3430 3200 3500 2800 3100 3200 3500 3000 3430 3000 3430 3200 3500 3200 3500 Trip Range 3 4 1610 1790 1610 1790 1610 1790 1610 1790 2570 2860 2570 2860 1610 1790 1610 1790 1610 1790 1610 1790 2570 2860 2570 2860 1610 1790 1610 1790 1610 1790 1610 1790 2570 2860 1610 1790 2570 2860 1610 1790 1610 1790 1610 1790 1610 1790 2570 2860 2570 2860 1610 1790 1610 1790 1610 1790 1610 1790 2570 2860 2570 2860 1610 1790 1610 1790 1610 1790 1610 1790 2570 2860 2570 2860 1610 1790 2570 2860 3860 4290 3860 4290 1610 1790 1610 1790 2570 2860 2570 2860 2570 2860 3800 4290 2570 2860 3800 4290 1610 1790 1610 1790 2570 2860 2570 2860 2570 2860 3860 4290 3860 4290 1610 1790 1610 1790 2570 2860 2570 2860 2570 2860 3860 4290 3860 4290 1610 1790 1610 1790 2570 2860 2570 2860 2570 2860 3860 4290 2570 2860 3860 4290 3860 4290 3860 4290 3700 4200 3400 3700 3700 4200 3860 4290 3860 4290 3700 4200 3700 4200 5 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 1960 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 3140 4710 4710 1960 1960 3140 3140 3140 4710 3140 4710 1960 1960 3140 3140 3140 4710 4710 1960 1960 3140 3140 3140 4710 4710 1960 1960 3140 3140 3140 4710 3140 4710 4710 4710 4700 4000 4700 4710 4710 4700 4700 6 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 2140 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 3430 5140 5140 2140 2140 3430 3430 3430 5140 3430 5140 2140 2140 3430 3430 3430 5140 5140 2140 2140 3430 3430 3430 5140 5140 2140 2140 3430 3430 3430 5140 3430 5140 5140 5140 6400 4800 6400 5140 5140 6400 6400 7 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 2320 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 3710 5570 5570 2320 2320 3710 3710 3710 5570 3710 5570 2320 2320 3710 3710 3710 5570 5570 2320 2320 3710 3710 3710 5570 5570 2320 2320 3710 3710 3710 5570 3710 5570 5570 5570 7300 5500 7300 5570 5570 7300 7300 Application High 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 2500 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 4000 6000 6000 2500 2500 4000 4000 4000 6000 4000 6000 2500 2500 4000 4000 4000 6000 6000 2500 2500 4000 4000 4000 6000 6000 2500 2500 4000 4000 4000 6000 4000 6000 6000 6000 8000 6000 8000 6000 6000 8000 8000 ETI Motor Circuit Protector Catalog Number 3-Pole — — — — — — — — — — — — — — — — — JXD63L400 JXD63H400 — — — — — — — — — — — — — — — — — CJD63H400 CJD63L400 — — — — — — — — — LXD63L600 LXD63H600 — — — — — — — — — — — — — — — — — — — — CLD63L600 CLD63H600 — — — LMXD63L800 LMXD63A800 — — — — Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Thermal Magnetic Catalog Number 2-Pole 3-Pole JXD22B200 JXD23B200 JXD22B225 JXD23B225 JXD22B250 JXD23B250 JXD22B300 JXD23B300 JXD22B350 JXD23B350 JXD22B400 JXD23B400 JXD62B200 JXD63B200 JXD62B225 JXD63B225 JXD62B250 JXD63B250 JXD62B300 JXD62B300 JXD62B350 JXD23B350 JXD62B400 JXD23B400 JD62B200 JD63B200 JD62B225 JD63B225 JD62B250 JD63B250 JD62B300 JD63B300 JD62B350 JD63B350 — — JD62B400 JD63B400 HJD62B200 HJD63B200 HJD62B225 HJD63B225 HJD62B250 HJD63H250 HJD62B300 HJD63B300 HJD62B350 HJD63B350 HJD62H400 HJD63B400 HHJD62B200 HHJD63B200 HHJD62B225 HHJD63B225 HHJD62B250 HHJD63B250 HHJD62B300 HHJD63B300 HHJD62B350 HHJD63B350 HHJD62B400 HHJD63B400 — CJD63B200 — CJD63B225 — CJD63B250 — CJD63B300 — CJD63B350 — CHD63B400 — — LXD62B450 LXD63B450 LXD62B500 LXD63B500 LXD62B600 LXD63B600 LD62B250 LD63B250 LD62B300 LD63B300 LD62B350 LD63B350 LD62B400 LD63B400 LD62B450 LD63B450 LD62B500 LD63B500 — — LD62B600 LD63B600 HLD62B250 HLD63B250 HLD62B300 HLD63B300 HLD62B350 HLD63B350 HLD62B400 HLD63B400 HLD62B450 HLD63B450 HLD62B500 HLD63B500 HLD62B600 HLD63B600 HHLD62B250 HHLD63B250 HHLD62B300 HHLD63B300 HHLD62B350 HHLD63B350 HHLD62B400 HHLD63B400 HHLD62B450 HHLD63B450 HHLD62B500 HHLD63B500 HHLD62B600 HHLD63B600 — CLD63B250 — CLD63B300 — CLD63B359 — CLD63B400 — CLD63B450 — CLD63B500 — — — CLD63B600 — LMXD63B500 LMXD62B600 LMXD63B600 LMXD62B700 LMXD63B700 — — LMXD62B800 LMXD63B800 LMD62B500 LMD63B500 LMD62B600 LMD63B600 LMD62B700 LMD63B700 LMD62B800 LMD63B800 Molded Case Circuit Breakers Adjustable Instantaneous Magnetic Trip Settings Breaker Type HLMXD6 HLMD6 MD6 MXD6 HMD6 HMXD6 CMD6 HND6 HNXD6 CND6 PD6 PXD6 HPD6 HPXD6 CPD6 RD6 RXD6 HRD6 HRXD6 5 4710 4710 4700 4700 4710 4710 4700 4700 4710 4710 6280 4710 6280 7860 4710 4710 6280 4710 6280 7860 4710 4710 6280 6280 4710 4710 6280 6280 4710 4710 4710 6280 4710 6280 7860 6280 7860 7860 7860 7860 7860 7860 6280 7860 7860 7860 7860 7860 7860 6280 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 6 5140 5140 6400 6400 5140 5140 6400 6400 5140 5140 6850 5140 6850 8575 5140 5140 6850 5140 6850 8575 5140 5140 6850 6850 5140 5140 6850 6850 5140 5140 5140 6850 5140 6850 8575 6850 8575 8575 8575 8575 8575 8575 6850 8575 8575 8575 8575 8575 8575 6850 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 7 5570 5570 7300 7300 5570 5570 7300 7300 5570 5570 7420 5570 7420 9290 5570 5570 7420 5570 7420 9290 5570 5570 7420 7420 5570 5570 7420 7420 5570 5570 5570 7420 5570 7420 9290 7420 9290 9290 9290 9290 9290 9290 7420 9290 9290 9290 9290 9290 9290 7420 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 High 6000 6000 8000 8000 6000 6000 8000 8000 6000 6000 8000 6000 8000 10000 6000 6000 8000 6000 8000 10000 6000 6000 8000 8000 6000 6000 8000 8000 6000 6000 6000 8000 6000 8000 10000 8000 10000 10000 10000 10000 10000 10000 8000 10000 10000 10000 10000 10000 10000 8000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 ETI Motor Circuit Protector Catalog Number 3-Pole — — — — — — — — — — — MXD63L800 MXD63A800 MXD63H800 — — — MXD63L800 MXD63A800 MXD63H800 — — — — — — — — — — — — CMD63L800 CMD63A800 CMD63H800 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Thermal Magnetic Catalog Number 2-Pole 3-Pole — HLMXD63B500 — HLMXD63B600 — HLMXD63B700 — HLMXD63B800 HLMD62B500 HLMD63B500 HLMD62B600 HLMD63B600 HLMD62B700 HLMD63B700 HLMD62B800 HLMD63B800 MD62B500 MD63B500 MD62B600 MD63B600 MD62B700 MD63B700 — — MD62B800 MD63B800 — — MXD62B500 MXD63B500 MXD62B600 MXD63B600 MXD62B700 MXD63B700 — — MXD62B800 MXD63B800 — — HMD62B500 HMD63B500 HMD62B500 HMD63B600 HMD62B700 HMD63B700 HMD62B800 HMD63B800 — HMXD63B500 — HMXD63B600 — HMXD63B700 — HMXD63B800 — CMD63B400 — CMD63B500 — CMD63B600 — CMD63B700 — — — CMD63B800 — — ND62B800 ND63B800 ND62B900 ND63B900 ND62B100 ND63B100 ND62B120 ND63B120 NXD62B900 NXD63B900 NXD62B100 NXD63B100 NXD62B120 NXD63B120 HND62B800 HND63B800 HND62B900 HND63B900 HND62B100 HND63B100 HND62B120 HND63B120 — HNXD63B900 — HNXD63B100 — HNXD63B120 — CND63B800 — CND63B900 — CND63B100 — CND63B120 — PD63B120 — PD63B140 — PD63B160 — PXD63B120 — PXD63B140 — PXD63B160 — HPD63B120 — HPD63B140 — HPD63B160 — HPXD63B120 — HPXD63B140 — HPXD63B160 — CPD63B120 — CPD63B140 — CPD63B160 — RD63B180 — RD63B200 — RXD63B180 — RXD63B200 — HRD63B180 — HRD63B200 — HRXD63B180 — HRXD63B200 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-71 MOLDED CASE CIRCUIT BREAKERS NXD6 Nominal AC Adjustable Trip Range Low 2 3 4 3000 3430 3860 4290 3000 3430 3860 4290 3200 3500 3700 4200 3200 3500 3700 4200 3000 3430 3860 4290 3000 3430 3860 4290 3200 3500 3700 4200 3200 3500 3700 4200 3000 3430 3860 4290 3000 3430 3860 4290 4000 4570 5140 5710 3000 3430 3860 4280 4000 4570 5140 5710 5000 5715 6430 7145 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 3000 3430 3860 4280 4000 4570 5140 5710 5000 5715 6430 7145 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 4000 4570 5140 5710 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 4000 4570 5140 5710 3000 3430 3860 4280 3000 3430 3860 4280 3000 3430 3860 4280 4000 4570 5140 5710 3000 3430 3860 4280 4000 4570 5140 5710 5000 5715 6430 7145 4000 4570 5140 5710 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 4000 4570 5140 5710 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 4000 4570 5140 5710 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 6 ND6 Maximum Continuous Amperes 500 600 700 800 500 600 700 800 500 600 700 800 800 800 500 600 700 800 800 800 500 600 700 800 500 600 700 800 400 500 600 700 800 800 800 800 900 1000 1200 900 1000 1200 800 900 1000 1200 900 1000 1200 800 900 1000 1200 1200 1400 1600 1200 1400 1600 1200 1400 1600 1200 1400 1600 1200 1400 1600 1800 2000 1800 2000 1800 2000 1800 2000 Application Molded Case Circuit Breakers Molded Case Switch — Circuit Disconnect Maximum Frame Amp Rating 1100 2-Pole Catalog Number BQ2S060 ■ BQ2S100■ Selection 3-Pole List Price $ 76.00 203.00 Catalog Number BQ3S060■ BQ3S100■ List Price $ 351.00 351.00 11000 11000 488.00 742.00 1495.00 895.00 1707.00 3251.00 4665.00 900.00 1962.00 11000 11000 11000 11000 11000 11000 11000 11250 11250 1125 ED22S100A■ ED42S100A■ ED42S125A■ ED62S100A■ — CED62S100A■ CED62S125A■ — — 1225 QJ22S225A■ 991.00 12000 1250 FXD62S250A HFXD62S250A■ 1622.00 2823.00 —— FXD63S250A HFXD63S250A■ CFD63S250A■ 1966.00 3422.00 6312.00 13200 13200 13200 JXD22S400A■ — — 2050.00 —— —— —— JXD23S400A JXD63S400A HJXD63S400A■ CJD63S400A■ 2529.00 3452.00 5824.00 7195.00 16000 16000 16000 16000 — — —— —— —— LXD63S600A HLXD63S600A■ CLD63S600A■ 4968.00 6644.00 11686.00 18000 18000 18000 — — —— —— —— LMXD63S800A■ MXD63S800A CMD63S800A 5708.00 5708.00 13259.00 10000 10000 10000 1200 — —— —— NXD63S120A CND63S120A■ 10082.00 18932.00 10000 10000 1600 —— PXD63S160A 14902.00 10000 2000 —— RXD63S200A■ 16508.00 1400 1600 1800 288.00 605.00 1157.00 698.00 —— 2600.00 3924.00 —— —— 306.00 ED23S100A ED43S100A ED43S125A ED63S100A ED63S125A CED63S100A■ CED63S125A■ HES3S100L HES3S125L QJ23S225A 6 MOLDED CASE CIRCUIT BREAKERS —— TD63S2000■ 21709.00 50kA 2500 —— TD63S2500■ 24441.00 50kA 3200 —— TD63S3200■ 26897.00 50kA 4000-5000 See “SB” Type Insulated Case Breakers For 2-pole application use outside poles of 3-pole circuit breaker. For additional lugs see pages 6-81 to 6-83. 6-72 Order by catalog number. Switches include frame and self protective (except TD) trip unit only. Order lugs separately from pages 6-81 to 6-83. 10000 2000 ■ Built to order. Allow 2–3 weeks for delivery. Ordering Information Withstand Non Automatic Molded Case Switch Self-Protective Instantaneous Override ±20% Molded case switches up to R frame contain a self protecting instantaneous element, which may open circuit above their override set point. UL file E57556 Volume 1, section 2 and CSA LR 42022-51. Requires mounting block MB9301 or MBR9302. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Lugs pages 6-81 to 6-83 Enclosures Section 5 Accessories pages 6-86 to 6-91 Discount Schedule MCCB Molded Case Circuit Breakers Digital Solid State Sentron Sensitrip III Series The Sentron Sensitrip III circuit Functions available in Sentron Sensitrip circuit breakers breaker is a true RMS current sensing Cont Long InstanShort device. Digital microprocessor Trip Current Time taneous Time circuitry within the electronic trip unit Catalog Number (Description + Suffix) Type Setting Delay Setting Pick Up provides more precise control over Basic Unit + (A) LI ⻫ ⻫ ⻫ the circuit breaker functions. This Basic Unit + (A)G LIG ⻫ ⻫ ⻫ control allows circuit coordination Basic Unit + (A)NT LSI ⻫ ⻫ ⻫ ⻫ flexibility not available with thermal Basic Unit + (A)NGT LSIG ⻫ ⻫ ⻫ ⻫ magnetic circuit breakers. Technical Short Time Delay Short Time l2t Pick Up ⻫ ⻫ ⻫ ⻫ Ground Fault Pick Up Ground Fault Delay ⻫ ⻫ ⻫ ⻫ Letter “A” is used for MD and ND Solid State frame types only. Typical Trip Unit Labeling and Adjustment Positions for the Sentron Sensitrip Circuit Breaker. SMD6, SHMD6, SCMD6, SND6, SHND6, SCND6, SPD6, SHPD6 SJD6, SHJD6, SCJD6, SCD6, SHLD6, SCLD6 6 MOLDED CASE CIRCUIT BREAKERS ln = Maximum circuit breaker ampere rating. lr = Current Rating — a function of continuous ampere adjustment setting expressed in % of ln . lg = Ground Fault Pickup — a function of adjustment setting expressed in % of ln . Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-73 Molded Case Circuit Breakers Digital Solid State Sentron Sensitrip III Series Technical D. Adjustable “Short Time Pick-Up” Switch (Optional) A. Adjustable “Continuous Amps” Rating Switch Sensitrip III circuit breakers with an adjustable short time pick-up switch allow for selection of short time pick-up in a range from 1.5 to 10 times the setting of the maximum current rating. All Sensitrip III solid state molded case circuit breakers have an adjustable ampere rating switch. Adjustments made to this switch change the continuous current rating of the breaker from 20% to 100% of its maximum trip unit rating depending on the circuit breaker frame. E. Adjustable “Short Time Delay” Switch (Optional) Sensitrip III circuit breakers with an adjustable short time pick-up switch also contain a switch for adjustment in time delay. The adjustable short time delay switch allows for either of two modes of short time delays. One range of settings enables the breaker to be set for fixed time delays and the other range of settings enables the breaker to be set for short time delays based on l2t curves. B. Adjustable “Long Time Delay” Switch All Sensitrip III circuit breakers have an adjustable long time delay switch to allow for selection of long time delays of fixed time intervals at six times the setting of the adjustable “continuous amps” rating switch. C. Adjustable “Instantaneous Pick-Up” Switch Sensitrip III circuit breakers with an adjustable instantaneous trip switch allow selection of a tripping point from related to the adjusted circuit breaker Rating (lr). Sensitrip III circuit breakers containing the optional equipment ground fault protection cover the ground fault pick-up range of 20% to 70% of the circuit breaker frame rating. The ground fault pick-up settings also allow for one of three time delays based on 12t curves. 6 MOLDED CASE CIRCUIT BREAKERS Adjustable “Ground Fault Pick-Up” Switch For 3-phase, 4-wire systems, an external neutral transformer is required with an ampere rating equal to the trip unit ampere rating. ln = Maximum circuit breaker ampere rating. lr = Current Rating — a function of adjustment setting expressed in % of ln. lg = Ground Fault Pick-up — a function of adjustment setting expressed in % of ln. Examples of Adjustment Settings Catalog Number SMD69800A In = 800 In = 800 amperes Results Continuous Current Setting Long Time Delay Setting Instantaneous Setting 30 240 amperes lr = 30% of 800 12 12 seconds trip at 6 x 240 amps = 1440. 8 1920 amperes 8 x lr = 8 x 240 Catalog Number SMD69800ANGT ln lr Setting Long Time Delay Short Time Pick-Up Off Instantaneous Setting Short Time Pick-Up On Short Time Delay l2T Set Ground Fault Pick-Up Ground Fault Delay 800 amperes Results 070 560 20 20 sec. — — 10 lr 5600A 8 lr 4480A .5 .5 secs .28 .28 sec @ 4480A 40 320A .2 .2 sec A 쎻 B 쎻 C 쎻 A ln = 800 amperes. 쎻 B lr = 560 amperes (70% of 800). 쎻 C Delay = 20 seconds at 3360 amps (6 x lr). 쎻 Breaker will trip in 20 seconds with 3360 amperes. D Short Time Pick-Up Off — Instantaneous can be used. 쎻 6-74 D 쎻 E 쎻 F 쎻 G 쎻 H 쎻 I 쎻 J 쎻 E Instantaneous set at 10 x lr = 10 x 560 = 5600 쎻 amperes. H l2t switch on .28 seconds @ 6 x 560 = 3360 amperes. 쎻 (Inverse time) F Short Time Pick-Up On — Set at 8 = 8 x 560 = 4480 쎻 amperes. I Ground Fault Pick-Up set at 40 = 40% of ln = 320 쎻 amperes. (Definite Time) G Short Time Delay = .5 seconds. (Definite Time) 쎻 G & 쎻 H are mutually exclusive. Note: 쎻 J Ground Fault Delay set at .2 seconds. Breaker will trip in 쎻 200 milliseconds with a 400 ampere ground fault. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog WL Power Circuit Breakers — Insulated Case 3-pole, up to 5000A General Breaker Description Minimal Space Requirements The WL design is extremely compact without sacrificing performance and does not use energy-wasting heat sinks. Non-Automatic Switch A special version of the circuit breaker is used as a non-automatic switch. The non-automatic switch is constructed without a trip unit and has no protective function. A possible application is for use as a tie in systems with parallel feeds. Main Bus Connectors Breakers are equipped with standard vertical main bus connections. Horizontal bus connections are available as an option in Frame Size 1 and 2 up to 2000A. Communication Capability MODBUS or PROFIBUS communications transmit the acquired and metered data, such as current values, breaker status, trip log, etc. to a central monitoring computer. When the optional metering function is installed, the WL acquires data useful for power management and can contribute to a significant savings in energy costs. A new, internal circuit breaker bus enables the expansion of breaker functionality through the integration of many secondary functions which were previously separate, including: ▪ Control of analog displays ▪ Options for testing the communication setup ▪ Display of breaker status and reason for trip ▪ Input modules for reading other external signals and transmitting these signalsvia PROFIBUS or MODBUS communication ▪ A selection of output modules to provide contact closures based on events or measured-value setpoints. It is not only possible to monitor the breaker remotely, it is also possible to open and close the breaker as well as setting parameters remotely ▪ Manual operating mechanism with mechanical and electrically interlocked closing ▪ Motorized operating mechanism with mechanical and electrically interlocked closing. Operating mechanisms with electrically interlocked closing are suitable for synchronizing tasks Auxiliary Contacts Auxiliary switches can be added according to the type of installation. They are easily mounted via front, top mounted terminal blocks. Modularity Common guide frames for the draw-out version make them completely interchangeable between the UL 489 and ANSI / UL 1066 rated circuit breakers. Components, such as auxiliary releases, motorized operating mechanisms, trip units, current sensors, auxiliary signal switches, automatic reset devices or interlocks can be used to modify or retrofit any circuit breaker to meet changing requirements. The main contacts can be replaced to extend the life of the circuit breaker and feature integrated contact wear indicators. Electronic Trip Unit Modularity Modularity is the outstanding feature of the new WL Circuit Breakers. The trip units themselves can be retrofitted with special LCDs, ground fault modules, rating plugs and communication modules.100% Rated Circuit Breaker WL circuit breakers are designed for continuous operation at 100% of their current rating without the need for external heat sinks. Conditions of Application WL Circuit Breakers are designed to meet standard Industrial and Commercial application requirements. Operating Mechanisms Circuit breakers can be optionally delivered with different operating mechanisms, including: ▪ Manual operating mechanism with mechanical closing (standard) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-75 MOLDED CASE CIRCUIT BREAKERS Standards ▪ WL ANSI / UL 1066 Circuit Breakers will satisfy: C37.13, C37.16, C37.17, C37.50, NEMA SG3 ▪ WL UL 489 Circuit Breakers will satisfy: UL 489 ▪ WL Circuit Breakers are suitable for use in UL 1558 LV Switchgear and UL 891 LV Switchboards Conditions of Application WL Circuit Breakers are designed to meet standard Industrial and Commercial application requirements. Uniform Dimensions WL Circuit Breaker dimensions differ only in the device width, which varies by frame size. With the exception of the 200kA ANSI Frame Size II which has an additional 5" in depth to accommodate integral fuses and the UL489 Frame Size I which measures only 15" in height to allow six-high stacking in switchboards. Trip Units The electronic, micro processor-based trip unit is auxiliary voltage-independent for all protective functions and enables adaptation to the different protection requirements of distribution systems, motors, transformers and generators. 6 The ever-increasing use of plant and energy management systems has intensified the demand for circuit breakers supporting multiple open protocols to monitor and control the flow of energy in the power system. The extensive and modular WL family of circuit breakers and accessories provides this for applications from 200A to 5000A. Applications WL breakers can be applied as main, tie, feeder or distribution breakers in low-voltage electrical power systems. Versions ▪ Frame ratings: 800A to5000A ▪ 3 physical frame sizes ▪ Rated nominal operating voltage up to 600VAC ▪ Seven interrupting classes from 50kA to 200kA at 480V ▪ Circuit breaker or non-automatic switch ▪ WL Circuit Breakers aredelivered as complete assembled breakers or individual frames, guide frames, and accessories Installation Types Fixed-mounted or Draw-out version. WL Power Circuit Breakers — Insulated Case Electronic Trip Units Selection criteria for WL Circuit Breakers The basic criteria for selecting circuit breakers is: ▪ Maximum Available Short Circuit at the installation point. This value determines the short circuit current interrupting rating or short circuit current withstand rating of the circuit breaker ▪ Rated Current In which is to flow through the respective circuit breaker continuously. This value may not be greater than the maximum rated current of the circuit breaker. The rated the rating plug, up to the maximum frame rating ▪ Ambient Temperature of the circuit breaker. This is usually the temperature inside the cubicle ▪ Design of the circuit breaker. Protective Functions of the circuit breaker. These are determined by the selection of the appropriate trip unit General Trip Unit Functions Basic Protective Functions Long-time overcurrent protection Short-time delayed overcurrent protection Instantaneous overcurrent protection Neutral conductor protection Ground fault protection L S I N G MOLDED CASE CIRCUIT BREAKERS 6 Additional Functions Selectable neutral protection Defeatable short-time protection Defeatable instantaneous protection Selectable thermal memory Zone selective interlocking Selectable I2t or fixed short-time delay Adjustable instantaneous pick-up Selectable I2t or I4t long-time delay Adjustable short-time delay and pick-up Selectable and adjustable neutral protection Dual protective setting capability Dynamic arc-flash sentry Extended instantaneous protection 6-76 ETU727 ● ● ● ● ● ● — — ● — ● ● ● ● — — — — — — — — — — — — ● ● — — — — — — ● ● Parameterization and Displays Parameterization by rotary switches (10 steps) Parameterization by communication (absolute values) Parameterization by menu/keypad (absolute values) Remote parameterization of the basic functions Remote parameterization of the additional functions Alphanumeric LCD Graphical LCD ● ● — — — — — — — — — — — — Metering Function Metering function Metering function Plus — — — — Communication CubicleBUS Communication via PROFIBUS-DP Communication via the MODBUS Communication via the Ethernet (BDA) — — — — — — — — ● Standard Fixed, ETU725 — Not available short-time delay only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Optional WL Power Circuit Breakers — Insulated Case Electronic Trip Units General Trip Unit Functions Basic Protective Functions Long-time overcurrent protection Short-time delayed overcurrent protection Instantaneous overcurrent protection Neutral conductor protection Ground fault protection L S I N G ETU755 ETU776 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● — — ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● — ● ● ● ● ● ● ● ● ● ● ● ● ● ● — — — — ● ● ● ● ● ● ● ● MOLDED CASE CIRCUIT BREAKERS ETU748 ● 6 Additional Functions Selectable neutral protection Defeatable short-time protection Defeatable instantaneous protection Selectable thermal memory Zone selective interlocking Selectable I2t or fixed short-time delay Adjustable instantaneous pick-up Selectable I2t or I4t long-time delay Adjustable short-time delay and pick-up Selectable and adjustable neutral protection Dual protective setting capability Dynamic arc-flash sentry Extended instantaneous protection ETU745 Parameterization and Displays Parameterization by rotary switches (10 steps) Parameterization by communication (absolute values) Parameterization by menu/keypad (absolute values) Remote parameterization of the basic functions Remote parameterization of the additional functions Alphanumeric LCD Graphical LCD ● ● — — — — — — ● ● ● — — — — ● ● ● ● ● — — — — — ● Metering Function Metering function Metering function Plus Communication CubicleBUS Communication via PROFIBUS-DP Communication via the MODBUS Communication via the Ethernet (BDA) ● Standard — Not available ● ● ● ● Optional Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-77 WL Power Circuit Breakers — Insulated Case MOLDED CASE CIRCUIT BREAKERS 6 3-Pole, up to 5000A Rating Plug It is no longer necessary to replace the current transformer to change the rated current of the breaker. Instead, you simply replace the rating plug which is easily accessible on the front of the trip unit. The circuit breaker is set to the new rated current quickly and is already correctly labeled. Long Time Overcurrent Protection with Switchable I2t/I4t Characteristics The long time overcurrent protection in the ETU745, ETU755 and ETU776 trip units can be switched between an I2t and I4t characteristic to improve coordination between upstream circuit breakers and fuses. Front Panel The front panel is designed so that it can be accessed through a cutout in the door, which means that all controls and displays are accessible even when the cubicle door is closed. The front panels of all Frame Size II and Frame Size III circuit breakers are identical, and allow for two different through-door access designs: Trip unit and front panel controls or front panel controls only. The degree of protection of the front panel is IP 20. Environmental Protection The plastics used are halogen-free and recyclable. Safety and Reliability In order to help protect the electrical distribution system and circuit breaker against unauthorized breaker operations, General a wide range of locking devices can be installed or retrofit, including: ▪ Lockable drawout version to protect against unauthorized removal (standard) ▪ High degree of protection through Plexiglas cover ▪ Mechanical reclosing lockout after long-time, short-time or instantaneous trip (optional) ▪ Devices with trip unit ETU745 or higher are equipped with temperature sensors on the BSS and COM15/COM16 (standard) ▪ Lock provision for locking the breaker in the OPEN position ▪ Lockable covers for the CLOSE button ▪ Lockable racking handle prevents moving the breaker ▪ Lockable charging handle prevents charging the springs Standard Version Features WL Circuit Breakers have the following standard equipment: ▪ Mechanical CLOSE and mechanical OPEN push buttons ▪ Manual operating mechanism with mechanical closing ▪ Contact position indicator ▪ Front panel ready-to-close indicator ▪ ▪ ▪ ▪ Dynamic Arc-Flash Sentry (DAS) employs the unique dual protective setting capability of the 755 and 776 trip units, coupled with the ability to easily toggle to a lower arc flash parameter set. A normal operation parameter set can be optimized for selective trip coordination, while the second set is optimized for lower arc flash energy levels. The dynamic action comes from the ability to switch from the normal operation set to the arc flash limiting set based on the presence of personnel as they approach the flash protection boundary. A wide variety of switching methods may be used based on the needs of a particular facility. The capabilities range from fully automatic switching using appropriate occupancy sensors to manual switching via a key operation. Extended Instantaneous Protection (Patent Pending) Extended Instantaneous protection (EIP), another unique feature of the WL trip unit, allows the system designer to achieve full selective trip coordination up to the short-time rating of the frame while also allowing application of the breaker up to the interrupting rating of the frame. The typical power circuit breaker with an 'LS' trip unit, or when the instantaneous function is switched off on an 'LSI' trip unit, can only be applied up to it's short-time rating, commonly 85kA or less. For application on systems with levels of available fault current above the short-time rating, the typical 'LS' power circuit breaker cannot be applied or must employ an instantaneous override. This instantaneous override is set at as much as 20% below the short-time rating and can seriously compromise selective trip coordination with downstream breakers. The WL, equipped with EIP, overcomes these limitations by providing full withstand capability, and full coordination, with a minus 0% short-time band tolerance up to 85kA on frame Size II and 100kA on Size III. Above fault currents of 20% higher than the full shorttime rating, the WL breaker is self-protecting, and the EIP function will trip the breaker instantly to protect the frame and the system from these extremely high currents, as high as 150kA on frame Size III. One added benefit is that arc flash energy is greatly reduced in this high current region due to the instantaneous trip response that EIP provides. ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Spring charge indicator Rear vertical main contacts Main contact replacement flag Auxiliary plug system with bare wire pressure screw terminals. Delivery includes all auxiliary plugs necessary for both factory installed and future field installed accessories Mechanical trip indicator of the overcurrent release system Automatic reset after trip The front panel cannot be removed if the circuit breaker closed Laminated main contact fingers as part of the breaker contact strip on the drawout circuit breaker Breaker position display in the operator’s panel Captive crank handle for racking out the breaker Guide frame with guide rails for easy handling of draw-out version Breaker cannot be moved in the CLOSED state Rated current coding between the guide frame and the breaker Suitable for reverse feed applications The breaker is always equipped with the required number of secondary disconnect blocks Exclusive Features Generator/Utility Protection Sets 24/7/365 power availability is critical for some systems. On-site generation capability is growing more and more common in many systems. All of the WL digital electronic trip units allow the system designer to precisely tailor trip settings for the most demanding requirements. However, the 755 and 776 trip units allow one set of trip settings for a fully loaded utility feed and with a simple contact closure, the trip unit toggles to a second trip set tailored to provide optimal generator protection. The wide range of settings allows the WL to provide protection for a minimal generator capacity for only essential loads, through full backup for an entire facility. This dual utility/generator protection capability in a single circuit breaker allows the system designer unparalleled, cost effective, flexibility. Dynamic Arc-Flash Sentry (Patent Pending) A unique feature of the WL trip unit allows the system designer to achieve lower levels of arc flash energy and delayed tripping for selective trip coordination purposes. 6-78 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Molded Case Circuit Breakers Electronic and Communications Accessories Selection Electronic & Display Devices Local Display Unit Breaker Type Catalog Number SJD, SLD, SMD, SND, SPD, SB, STD LDU-100 List Price $ SADU Ammeter Display Unit 1343.00 The Local Display Unit (LDU) provides a centralized read-out of all Sensitrip III and SB ICCB breakers. The device provides a panel mountable display for all trip unit data including phase currents and alarms for up to 32 breakers. Also communicates with other ACCESS™ devices. Trip Unit Test Set Type Catalog Number List Price $ SJD, SLD, SMD, SND, SPD, SB, STD, Portable TS31 13835.00 Spare TS-31 Test Set Interconnecting Cable TS31CABLE 188.00 The TS-31 test set is used to test the operation of the fault protection functions of the circuit breaker's trip unit, including long-time, short-time, instantaneous, and ground fault by means of secondary current injections. Sensitrip Ammeter Display Unit Breaker Type Catalog Number SJD, SLD, SMD SADU SND, SPD SADURMK18 List Price $ 1776.00 342.00 SB Energy Display Trip Unit Powered & Battery back-up 2 x 16 LCD Alphanumeric Display* Ammeter Display Functions — RMS Phase Currents — Average Current* — Current Demand* — Ground Current — Current Unbalance (%)* ▪ Breaker Status — Normal — Impending Trip* ▪ Time Stamped Trip Log (last 5) — Time & Date* — Trip Cause: LT, ST, GF, SC ▪ Max Log (with date & time) — Max Phase Current* — Max Average Current* — Max Ground Current* — Max Unbalance Current* — Max Current Demand* * Unique Features Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-79 MOLDED CASE CIRCUIT BREAKERS SADU Plug-in Mounting Direct plug-in or Panel Mounting* 6 The Sensitrip Ammeter Display Unit (SADU) provides real-time metering for all Sentron-Sensitrip III Molded Case Circuit Breakers. The unit plugs directly onto the front of the trip unit and provides displays for individual phase currents flowing through the breaker. Additional features include Average, Demand, Ground and Unbalance Current displays, along with impending Trip Status. Current Metering Logs, and a unique diagnostic Trip Log that records the date, time and type of fault for the previous five breaker trips. The device is UL and CSSA certified. The optional panel mount accessory (SADURMK18) allows easy device mounting external from the circuit breaker, in panelboard and switchboard spaces or gutters, with the flexibility of interior panel exterior panel, or wall mounting capability. The 2 x 16 alphanumeric LCD display provides easy viewing of data, such as viewing all three phase currents simultaneously. ▪ ▪ ▪ ▪ Molded Case Circuit Breakers Communications Accessories Selection Multiplexor Translator Breaker Type Features SJD, SLD SMD, SND SPD, STD SBA, SBS, SBH Zone Interlocking Only Catalog No MTZ List Price $ 1946.00 Full Communications with Zone Interlocking MTA 4334.00 The Multiplexor Translator MTZ is an interface device required in zone selective interlock schemes. The MTA combines the zone selective interlocking function with interface to ACCESS® Systems. Cables & Connectors Ribbon Cables Breaker Type Length SJD, SLD SMD, SND SPD, STD SBA, SBS, SBH 06" 08" 12" 18" 24" Catalog No List Price $ EPC06 EPC08 EPC12■ EPC18 EPC24■ 59.00 59.00 79.00 96.00 124.00 List Price $ MOLDED CASE CIRCUIT BREAKERS 6 Telephone Cables ACCESS™ Communications 햲 Siemens electronic trip units feature two levels of communication: Zone Selective Interlocking and ACCESS™ System Open-protocol communications. The trip units are fully equipped for direct integration into ACCESS™ or compatible communication systems. A multiplexor/Translator (MTA) and Expansion Plug area required for the TYPE “TL” and Sensitrip trip units when full Access™ communications is specified. The MTA also has Zone Selective Interlocking capability. Refer to Bulletin IPIM-2211A and Instruction Sheet Pc. No. 411152A00 for additional information. Siemens WinPM.net power monitoring software delivers a powerful energy management system providing sophisticated monitoring capability to a host computer and other components in the electrical distribution system at an affordable cost. It also provides process control, including peak demand, trend analysis, waveform analysis, and harmonic calculations and displays. These functions help pinpoint energy consumption, power quality issues, and the energy cost of any process. Outages and potential outages can be quickly diagnosed and plans can be generated for expansion and preventative plant maintenance. Refer to Bulletins IPIM-2211A for additional information. Communications is accomplished via RS-485 twisted pair wire or modem, providing communications to a remote site and allowing access to multiple plants. With integration of an Access™ Siemens Power Interface (SPI), communication with Modbus networks is enabled. This part provides the ability to communicate directly to a PC with WinPM.net or any Modbus master. The SB-EC Trip Unit’s RS-232 communications port provides additional PC communications for available trip unit data displays and trip unit configuration via Siemens SBWin™ software. ■ Built to order. Allow 2–3 weeks for delivery. ▲ Built to order. Allow 6–8 weeks for delivery. 6-80 Breaker Type Length Catalog No SB STD 08' 15' 25' 50' MTCSB08 ▲ MTCSB15 ▲ MTCSB25 ▲ MTCSB50 ▲ 79.00 118.00 155.00 155.00 SJD, SLD SMD, SND, SPD, SBA, SBS, SBH 8' 15' 25' 50' MTC08 MTC15 MTC25 MTC50 79.00 118.00 155.00 155.00 The Expansion Plug EP is a required isolating device to connect the breaker with the Multiplexor Translator. It is connected to the trip unit on the breaker with a “Ribbon Cable”, EPC08 e.g., and the Multiplexor Translator with the “Telephone Cable” (an RJ-11 cable) MTCSB08 e.g. Expansion Plug Selection Guide Breaker Type Frame Size Mounting Type Catalog Number List Price $ SB ICCB and STD 1200A, 2000A Fixed EPSBFMK햲 ■ 219.00 Draw out EPSBDMK햲 ■ 219.00 SB ICCB and STD 3200A, 5000A Fixed EPSB4FMK 햲 ■ 219.00 Drawout EPSB4DMK햲 ■ 219.00 Sensitrip ALL ALL EP 209.00 Component Selection Guide 햳 Trip Units and Application Component Type ZSI (only) with Sensitrip MCCB’S Access and/or ZSI with Sensitrip MCCB’s EP ✓ ✓ EPSB MTZ 햴 ✓ ZSI (only) with all SB-EC Trip Units ACCESS ACCESS and/or with SB-TL Trip Units ✓ ✓ ✓ ✓ MTA 햴 EPC Cable ✓ ✓ MTC Cable 햵 ✓ ✓ 햲 Factory wired when ACCESS communications or ZSI is ordered for the SB breaker from the factory. 햳 When ordered with circuit breaker from the factory. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햴 햵 ✓ ✓ ✓ MTCSB Cable ACCESS with SB-EC Trip Units ✓ One MTA or MTZ per eight trip units when required. Always required when multiple MT’s are used. One additional cable per each additional MT. Discount Schedule MCCB Lug information Mechanical Lug For Use With Type(s) Circuit Breaker Ampere Rating Selection Cables Per Lug Lug Wire Range Catalog Number List Price $ 15–40 1 1 #14–#6 AWG Cu #12–#6 AWG Al TC1Q1 2.60 45–100 1 1 #8–#1 AWG Cu #6–#1/0 AWG Al TA1Q1 2.60 15–20 1 1 #14–#10 AWG Cu #12–#10 AWG Al 25–35 1 1 #14–#6 AWG Cu #12–#6 AWG Al Switching Neutrals 40–50 1 1 #8–#6 AWG Cu #8–#4 AWG Al BG, BLG 55–70 1 1 #8–#4 AWG Cu #8–#2 AWG Al 80–100 1 1 #4–#1/0 AWG Cu #2–#1/0 AWG Al 110–125 1 1 #2–#1/0 AWG Cu #1/0–#2/0 AWG Al Line Side BQ, BQH, BQHF BQE, BQF, BL, BLH, HBL, HBQ Load Side Lugs are integral to Circuit Breaker Line Side (CQD, CQD6) & Load Side BQD, CQD BQD6, CQD6 NGG #14–#6 AWG Cu #12–#6 AWG Al Integral 45–100 1 #8–#1 AWG Cu #6–#1/0 AWG Al Integral 15–30 1 #14–#6 AWG Cu #12–#6 AWG Al TC1Q1 2.60 15–30 1 #14–#6 AWG Cu 3TC1Q1 7.20 (pkg. of 3) 35–125 1 #8–#1/0 AWG Cu #8–#2/0 AWG Al 3TC1GG20 13.40 (pkg. of 3) 15–125 — NUT KEEPER PLATE TNKG3 17.90 (pkg. of 3) 1 #14-3/0 AWG Cu 3TW1EG30 12.80 (pkg. of 3) 1 #14-1/0 AWG Cu/Al 3TA1EG10 12.80 (pkg. of 3) 15-125 1 #6-3/0 AWG Cu/AI 3TA1EG30 12.80 (pkg. of 3) 15-125 — Nut Keeper Kit (3-pole) TNKE3 12.30 (pkg. of 3) 15-125 — Nut Keeper Kit (4-pole) TNKE4 15.60 (pkg. of 4) Note: (A) Molded case circuit breakers having a rated ampacity of 125 amperes or less are to be connected with 60 or 75° C wire. Circuit breakers having a rated ampacity greater than 125 amperes shall only be cabled with 75° C cable unless otherwise indicated on the circuit breaker label. Exceptions to this rule are outlined in article 110-14 C(1)(2) of the 2005 National Electrical Code. (B) Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards. Discount Schedule MCCB Lug is steel. in package of six. nut keeper plate is required with each lug on the NGG breaker. Sold One Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-81 MOLDED CASE CIRCUIT BREAKERS 15-125 15-125 6 NEG, HEG 1 15–40 Lug Information Aluminum Body Lugs for Copper or Aluminum Wire For Use With Type(s) Circuit Breaker Ampere Rating Cables Per Lug QJ2, QJH2 QJ2H, HQJ2H 60–225 1 15–25 1 30–100 110–125 Catalog Number List Price $ #6 AWG–300 kcmil (Cu) #4 AWG–300 kcmil (Al) TA1Q300 13.40 (pkg. of 3) #14–#10 AWG (Cu) #12–#10 AWG (Al) SA1E025 1 #10–#1/0 (Cu or Al) LN1E100 1 #3-3/0 (Cu) #1-2/0 (Al) TA1E6125 30–60 1 #10–4 (Cu or Al) LD1E060 (Load Side) 12.70 70–100 1 #4–#1/0 (Cu or Al) LD1E100 (Load Side) 3.90 FXD6-A, FD6-A, HFD6, CFD6 HHFD6 70–250 1 #6 AWG–350 kcmil (Cu) #4 AWG–350 kcmil (Al) TA1FD350A 22.00 SJD6(A), SHJD6(A) SCJD6 65-200 1–2 #4 AWG–3/0 (Cu or Al) TA2J630 32.50 JXD2(A), JXD6(A), JD6(A), SJD6(A), HJD6(A), HJXD6(A) HHJXD6, HHJD6, SHJD6(A), CJD6, SCJD6 200–400 1–2 3/0–500 kcmil (Cu) 4/0–500 kcmil (Al) TA2J6500 31.50 LXD6(A), LD6(A), SLD6(A), HLD6(A), HLXD6(A), HHLXD6, HHLD6, SHLD6(A), CLD6, SCLD6 250–600 1–2 3/0–500 kcmil (Cu) 4/0–500 kcmil (Al) TA2J6500 31.50 500–600 1–2 #1–500 kcmil (Cu or Al) TA2K500 71.00 1–3 1/0–500 kcmil (Cu or Al) TA3K500 All 2, 3-pole ED2, ED4, ED6, ED6 ETI, HED4, HHED6 6 CED6 All 1-pole ED, HED MOLDED CASE CIRCUIT BREAKERS Selection LMD6햲, LMXD6햲, HLMD6햲, HLMXD6햲, MD6, MXD6, SMD6, HMD6, HMXD6, SHMD6, CMD6, SCMD6 500–800 ND6, NXD6, SND6, HND6, HNXD6, SHND6, CND6, SCND6 800–1200 PD6, HPD6, CPD6 PXD6, HPXD6, SPD6, SHPD6 1200–1600 PD6, PXD6, HPD6, HPXD6, SPD6, SHPD6, RD6, RXD6, HRD6, HRXD6, STD 1200–2000 햲 Use TA2K500 or TA3K500 only. for 100% rated MD/ND frame breakers. 햳 Used 6-82 1–2 Lug Wire Range 3.90 3.90 12.70 98.00 햳 101.00 500–750 kcmil (Cu or Al) TA2N750 250–500 kcmil (Cu or Al) 2TA4P8500 햳햴 3TA4P8500 햵 584.00 843.00 250–500 kcmil (Cu or Al) 2TA4N8500 햴 3TA4N8500 햵 588.00 853.00 1–5 300–600 kcmil (Cu or Al) TA5P600 320.00 1–6 300–600 kcmil (Cu or Al) TA6R600 338.00 1–4 햴 Contains 햵 Contains 2 connectors plus 1 NDTS end barrier. 3 connectors plus 1 NDTS end barrier. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Lug information Optional Mechanical Lugs For Use With Type QJ2, QJH2, QJ2H, HQJ2H ED, HED 1, 2 & 3-pole HFD6, HHFD6, CFD6, F(X)D6-A J(X)D2(A), J(X)D6(A), HJD6(A), HHJD6, SHJD6(A), L(X)D6(A), HHLD6, SCD6, HLD6(A), SHLD6(A), CJD6, CLD6, SCJD6, SCLD6 SMD6, M(X)D6, HM(X)D6, HMD6, CMD6, SCMD6, SND6, N(X)D6, HN(X)D6, SHND6, CND6, SCND6 R(X)D6, HR(X)D6 P(X)D6, HP(X)D6, CPD6, SPD6, SHPD6 Selection Circuit Breaker Ampere Rating Cables Per Lug Lug Material Lug Wire Range Qty Per Catalog No 60–225 1 Cu #6 AWG–250 kcmil (Cu) 3 1, 2 & 3-pole 30-125 1 Cu #10–#1/0 (Cu) 70–250 1 Cu #6 AWG–350 kcmil (Cu) 1 TC1FD350 34.50 200–600 1 1–2 Cu 3/0–600 kcmil (Cu) 3/0–500 kcmil (Cu) 1 1 TC1J6600 햲 TC2J6500 햲 77.00 76.00 250–600 1 1 Al 500–750 kcmil (Al) 500–600 kcmil (Cu) 1 TA1L6750 76.00 1–2 1–3 Cu Cu 1–2 Al 1–3 Al 1 1 2 3 2 3 1 TC2K500 TC3K350 2TA2N8750 3TA2N8750 2TA3N8750 3TA3N8750 TC5R600 120.00 151.00 365.00 513.00 579.00 832.00 426.00 1 TA4P750▲ 254.00 500–600 1600–2000 1–5 Cu 1200–1600 1–4 Al 600–750 kcmil (Cu/Al) 800–1200 TC1Q250 TC1ED6150 #1 AWG–500 kcmil (Cu) #1 AWG–350 kcmil (Cu) 500–750 kcmil (Cu) 500–750 kcmil (Al) 500–750 kcmil (Cu) 500–750 kcmil (Al) 300–600 kcmil (Cu) 700–800 Catalog Number List Price $ 32.00 (pkg. of 3) 33.50 Compression Lugs 500–800 N(X)D6, HN(X)D6, CND6, SND6, SHND6, SCND6 900–1200 Lugs Per Kit Lug Wire Size Catalog Number List Price $ 1, 2, 3 2, 3 2, 3 1 1 1 #2/0 AWG Cu/Al 350 kcmil Cu/Al 350 kcmil CCE125 CCQ225 CCF250 27.00 51.00 51.00 2, 3 1 500 kcmil CCL600 150.00 2 6 CCM800K2 726.00 3 2 9 8 500 kcmil CCM800K3 CCN1200K2 1056.00 951.00 3 12 CCN1200K3 1393.00 Distribution Lugs* For Circuit Breaker Types Ampere Rating Poles Lugs Per kit Wires Per Lug Lug Wire Size Catalog Number List Price $ NEG, HEG 15-125 1,2,3 3 3 #14-#2 AWG Cu 3TA3EG02 101.00 (for 3) NEG, HEG 15-125 1,2,3 3 6 #14-#6 AWG Cu 3TA6EG06 101.00 (for 3) ED2, ED4, ED6, HED4, HHED6, CED6 15-125 1,2,3 1 6 #14-#4 AWG Cu #6-#4 AWG Al TA6ED06 33.50 70-250 2,3 1 6 #14-#4 AWG Cu #6-#4 AWG Al TA6FD04 41.50 6 #14-2/0 AWG Cu TA6JD20 #6-2/0 AWG Al 89.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-83 F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6-A, SJD6, SHJD6-A, SCJD6, L(X)D6-A, HL(X)D6-A, CLD6-A, SLD6-A, SHLD6-A, SCLD6 * Special purpose wire connectors, not for general use. 햲 Used 200-600 2,3 1 for 100% rated JD/LD frame circuit breakers. ▲ Built to order. Allow 6–8 weeks for delivery. Discount Schedule MCCB MOLDED CASE CIRCUIT BREAKERS M(X)D6, HM(X)D6, CMD6, SMD6, SHMD6, SCMD6 Poles 6 Ampere For Circuit Breaker Types Rating Lugs (contains indicated number of lugs and necessary hardware per kit) ED2, ED4, ED6, HED4, HHED6, CED6 15–125 QJ2, QJH2, QJ2-H 125–225 F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 125–250 JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6, SJD6-A, SHJD6-A, 200–600 SCJD6, L(X)D6-A, HL(X)D6-A, CLD6, SLD6-A, SHLD6-A, SCLD6 Kits (contain lugs and hardware for complete line or load end of 2 or 3-pole breaker) Molded Case Circuit Breakers MOLDED CASE CIRCUIT BREAKERS 6 Modifications A variety of internal and external accessories, as well as modifications, are available to adapt Siemens circuit breakers to special installation requirements. UL listed internal accessories for 100 through 2000A circuit breakers are field-addable. Internal accessories fine tune an electrical distribution system, allowing control of the circuit breakers to meet special application requirements. For example, emergency situations may dictate tripping critically placed circuit breakers quickly. Shunt trips accomplish this conveniently and efficiently. Or, when voltage drops are a concern, undervoltage trips automatically open the circuit breaker at a predetermined voltage level. A wide range of external operating and mounting accessories is also available. For example, face, shallow, and back mounting plates are ideal for tailoring BQ circuit breakers to OEM applications. A complete line of operating handles and handle-blocking devices meet switchboard, enclosure and safety needs. Plug-in mounting assemblies, which simplify switchboard mounting of circuit breakers and permit breaker removal without disconnecting bus or cable connections, are available. General/Selection 50°C Ambient Calibration — Not UL listed and not available for solid state, 100% rated breakers or 400HZ calibrated breakers. For BL Type Circuit Breakers — Add suffix ‘M’ to catalog number (Example: B120M) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .No Charge For BQ, QJ2, and ED Frame Circuit Breakers — Replace ‘B’ in catalog number with ‘M’ . . . . . . . . . . . . . . . . . . . . . . . .No Charge (Example: BQ3M060, QJ23M200, ED63M060) For EG Frame Circuit Breakers — Replace ‘B’ in catalog number with ‘C’ (Example: NEG3C015) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Add 10% to list price For FD, JD, LD, LMD, MD, ND, PD, and RD Frame Circuit Breakers Non-Interchangeable Trip (3–pole only) . . . . . . . . . . . . . . . . . . . . . . . . . . . .No Charge — Replace ‘B’ in catalog number with ‘M’ (Example: FXD63M225, JXD63M400) Interchangeable Trip (trip unit only, 3–pole only) . . . . . . . . . . . . . . . . . . . .No Charge — Replace ‘T’ in catalog number with ‘W’ (Example: FD63W200, JD63W400) 400 HZ Calibration UL Listed (5KA IR) For BQ & BL Type Circuit Breakers (200A max.) . . . . . . . . . . . . . . . . . . . . .Add 25% to list price — Add suffix ‘Y’ to catalog number Not UL Listed For all other Circuit Breakers, see derating tables on page 6-152 and order standard circuit breakers. Fungus Proofing — In accordance with MIL-T-152. All BQD, CQD, NGG, ED, FD, JD, LD, LMD, MD, ND, PD, and RD, Frame Circuit Breakers are inherently fungus resistant and do not require special treatment. Fungus proofing in accordance with MIL-T-152 For BL, and BQ Type Circuit Breakers — Order must be placed directly with the factory by the sales office . .Add $10.00 net per pole For all other Circuit Breaker Types — Order must be placed directly with the factory by the sales office . .Add $160.00 net per device Certificate of Compliance with Test Report (catalog number CERT OF COMP.) Add $210.00 net Certificate of compliance testing must be performed on the actual device being shipped. The certificate cannot be provided after initial shipment. Order for devices with COC requirement must be placed directly with the factory by the sales office and shipped directly to the end user. UL 489 Supplement SB Naval Use Breakers Ordering Information Breakers tested to UL 489 Supplement SB are qualified for use on non combat and auxiliary naval vessels. For “NAVAL” label, add $75. net per catalog number per order. Order must be placed directly with the factory by Siemens Sales Office. Siemens’ molded case breakers from the ED frame through the 2000 Amp SB frame can be labeled “Naval” in compliance with Supplement SB. Supplement SB testing comprises two sets of vibration tests. The first is to find mechanical resonances in the product and to subject the breaker to extreme testing at each resonant frequency. The second is a swept frequency test, in which the frequency of excitation is changed in intervals of 1Hz, and held at each frequency for five minutes. The excitation frequencies run from 4 to 33Hz, and the test is conducted in each of the three orthogonal axes of the breaker. During these tests, the breaker must not trip from the closed position, nor may the contacts touch from the open position. Calibration and insulation resistance are also verified during the test. For detailed information, refer to UL 489, Supplement SB. 6-84 Types BQD/CQD NGG ED2, ED4, ED6, IIED4, HED6 CED6 FD6, FXD6, HFD6, HFXD6 CFD6 JXD2, JD6, JXD6, LXD6, LD6, HJD6, HJXD6, HLD6, HLXD6 HHJD6, HHJXD6, HHLD6, HHLXD6 CJD6, CLD6 MD6, MXD6, HMD6, HMXD6, CMD6, ND6, NXD6, HND6, HNXD6, CND6 PD6, PXD6, HPD6, HPXD6, CPD6, RD6, RXD6, HRD6, HRXD6 SBA400, SBS400, SBA800, SBS800, SBA1200, SBS1200, SBA1600, SBS1600, SBA2000, SBS2000 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog UL File E10848, Vol 10, Sec 1 E10848, Vol 10, Sec 2 E10848, Vol 4, Sec 11 E10848, Vol 4, Sec 13 E10848, Vol 4, Sec 17 E10848, Vol 4, Sec 18 E10848, Vol 4, Sec 8 E10848, Vol 4, Sec 20 E10848, Vol 4, Sec 14 E10848, Vol 4, Sec 15 E10848, Vol 4, Sec 19 E9896, Vol 15, Sec 1 Molded Case Circuit Breakers Internal Accessories General Feature Combinations The available feature combinations are shown in the chart below. For applications requiring combinations of features not listed in this chart, consult the sales office for availability. Breakers Modules Avail. On ST/ Per Breaker ST/ ST/ AUX/ UVT/ Breaker Poles ST AUX ALSW ALSW UVT AUX UVT/ UVT/ ST/ ALSW ALSW AUX AUX/ ALSW Elect. Bell Ground Grd fault ALSW Alarm fault w/Bell QP, BQ, BL햲 1 1, 2, 3 1 — — — — — 1,2 — — — — BQD, CQD, NGG 1 2, 3 1 1/1 — — — — 1,2 1/1 1 — — — QJ햲 1 3 1 1/1 — — — — 2 — — — — — 1 — All ED 1 1, 2, 3 1 1/1,1/2 1/1 1/1/1 1 1/1, 1/2 1/1 1/1/1 1, 2 1/1, 2/1 1 — 1 All FD 2 2, 3 1 — — — 1 1/1 — — 1, 2 1/1 1 — — — All JD, LD, LMD햳 2 2, 3 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — — 1 3 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — — 2 2, 3 1 1/1 — — 1 1/1, 1/2 — — 1, 2 1/1, 2/1 1, 2 — — — 1 1 — — SJD6, SHJD6, SCJD6, SLD6, SHLD6, SCLD6햴 All MD, ND, PD, RD Including Electronic trip햵 1 NC / 1 NO, 2 NC / 2 NO, STD햶 6 3 1 — — — 1 — — — 3 NC / 3 NO, — 4 NC / 4 NO, 5 NC / 5 NO, 6 NC / 6 NO Shunt Trip (ST) When voltage drops to a value below 35% of the nominal coil rating, the undervoltage trip device automatically opens the breaker. The operation is instantaneous, and the circuit breaker cannot be reclosed until the For applications requiring remote “on” or “off” indication (or electrical interlocking), auxiliary switches are available. Each switch comprises an “A” (open when circuit breaker is open) and a “B” (closed when circuit breaker is open) contact with a common connection. (Form C) For ED Frames 햲 Factory assembled only mechanical interlock is installed, no accessory module can be installed in the right pocket. 햳 If For FD Frames 햴 If mechanical interlock is installed, no accessory module can be installed. 햵 If mechanical interlock is installed, no accessory module can be installed in the left pocket. The alarm switch contact is closed when the circuit breaker is opened automatically by an overload, short circuit, shunt trip or undervoltage trip. The alarm switch contact is open when the circuit breaker is reset. For JD and LD Frames 햶 One module per column. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-85 MOLDED CASE CIRCUIT BREAKERS Undervoltage Trip (UVT) Auxiliary Switch (AUX) Alarm Switch (ALSW) 6 One or all critical circuit breakers may be tripped from a distant control point by use of a shunt trip device. A shunt trip operates through an auxiliary switch contact; when the breaker opens, current is not maintained on the shunt trip coil. voltage returns to 85% of line voltage. The undervoltage trip, which is continuously energized, must be energized before the circuit breaker can be closed. Molded Case Circuit Breakers External Accessories Selection Handle Ties Provide simultaneous switching of 2 adjacent handles. Do not provide common trip. For Use With Breaker Frame(s) Catalog Number List Price $ each Standard Package Wt Lb/ Std Pkg BQ, BQH, HBQ, BLH, HBL ECQTH3 200.00햲 50 1 BQXD, BL, BQ, BQH, HBQ, BLH, HBL ECQLD3 98.00햲 10 1 One pole BL, BLF, BE, BAF ECPLD1 10.10 10 1 Two pole BL, BLF and BE ECPLD2 10.20 10 1 All QJ HL9419 15.10 10 1 All BQD, CQD BQDPLD 18.40 01 1 NGG HPLG 17.90 01 1 EB, 1- thru 3-pole HPLEB 11.20 01 1 EG, 3- and 4-pole only HPLE 15.60 01 1 All ED ED2HPL 16.00 01 1 All FD FD6PL1 15.00 01 1 All JD, LD, LMD JD6HPL 24.00 01 1 All MD, ND, PD, RD MN6PLD 62.00 01 1 STD STDPLD ■ 131.00 01 1 2.80 01 1 ⁄4 Padlocking Devices For locking breaker in “OFF” position. QTH3 ⁄4 ⁄4 ⁄4 ⁄4 ⁄8 ⁄4 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 FD Padlocking Device FD6PLI Padlocking Device QLD3 Filler Plates BQ, BQH, HBQ QF3 ⁄4 Handle Blocking Devices 6 BL, BLH, HBL, BQXD, BQ, BQH, HBQ ECQL1 MOLDED CASE CIRCUIT BREAKERS For holding breaker in “ON” or “OFF” position. Not a lockout/tagout device. QJ2, QJH2, QJ2H, HQJ2H All BQD, CQD, NGG 97.00햲 10 QJHS1 13.40햲 25 1 BQDHBD 10.60 01 1 EG HBDE 15.60 01 1 All ED E2HBL 16.00 01 1 All FD FD6HB1 18.40 01 1 All JD, LD, LMD JD6HBL 22.00 01 1 All MD, ND, PD, RD MN6BL 62.00 01 1 01 2 1 ⁄4 Filler Plate QF3 ⁄4 ⁄4 ⁄4 ⁄2 ⁄2 ⁄2 Handle Extensions For replacement. One extension shipped with breaker. All MD, ND, PD, RD EX11 109.00 STD EXSTD■ 137.00 FD Handle Blocking Device FD6HB1 Terminal Shields Breaker Type Poles Catalog Number List Price $ each NGG 3 TSSG3A 28.00 Handle Blocking Device QL1 Standard Package 1 Handle Extension EX11 ■ Built to order. Allow 2–3 weeks for delivery. Note: CSO = Consult Sales Office only in standard package quantities. 햲 Sold 6-86 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers External Accessories Selection Mounting Clips For Use With Breaker Frame(s) Number of Poles Catalog Number BQ, BQH 1 MB120 List Price $ each 8.50 Standard Package Wt Lb Std Pkg 20 1 ⁄4 MB120 Face Mounting Plates GFCI 1 FP9558 14.50 10 1 ⁄2 FP9508 FP9555 FP9556 13.40 17.00 18.40 10 10 10 1 BQ, BQH, BQXD 1 2 3 1 2 3 CQDFMB1 CQDFMB2■ CQDFMB3■ 28.00 31.50 35.00 1 1 1 1 CQD, CQD6 FMPG1 FMPG2 FMPG3 27.00 29.50 33.50 1 1 1 1 NGG 1 2 3 SMB6 5.30 30 11⁄2 ⁄2 1 11⁄2 ⁄4 ⁄4 1 ⁄4 1 Face Mounting Plates FP9558 FP9508 FP9555 FP9556 ⁄4 1 ⁄4 1 ⁄4 Shallow Mounting Brackets BQ, BQH 1–6 Back Mounting Plates All QP 1 and 2-pole 1, 2 I0204ML1125 31.50 10 1 All QP 3-pole 3 I0303ML3100 59.00 10 1 2 3 4 BR2 BR3 BR4 17.00 17.00 17.00 10 10 10 1 1 E2BMB 14.20 1 1 CQD, CQD6 CQDSMK 17.70 1 11⁄4 NGG MSKG4 3.90 1 1 All QJ MSQJ 4.40 1 1 BQ, BQH, BQXD ED2, ED4, ED6, HED4, HED6 ⁄4 ⁄4 SMB6 (6 shown) ⁄4 ⁄4 1 ⁄4 QML12 1 ⁄4 Mounting Screw Kits All ED (CED6 requires 2 kits) MSE6 MSE6100 4.40 1.10 1 100 1 MSF6 MSF650 4.40 1.10 1 50 1 All FD (CFD6 requires 2 kits) All EG 1-pole MSKE1 3.90 — — All EG 2-pole MSKE2 5.00 — — All EG 3 or 4-pole MSKE4 6.20 — — All JD, LD MSJ6 14.20 1 1 All LMD MSLMD 24.00 1 1 All MD, ND, MSMN 24.00 1 1 All PD, RD MSPR6 57.00 1 2 Back Mounting Plate BR2 MOLDED CASE CIRCUIT BREAKERS ⁄4 1 ⁄4 1 ⁄4 ⁄4 ⁄4 Mounting Screw Kit MSE6 “MI” Mechanical Interlocks For Use With Breaker Type(s) Panel Mounted BQ — ECQML12 299.00 10 All EG (Sliding Bar) HSBE — 553.00 1 — All EG (Walking Beam) WBMEFM — 604.00 1 — All QJ CSO — — All FD MI5444 MI5444 604.00 1 — All JD, LD MI5413 — 604.00 1 1 All LMD MI5406 ■ — 604.00 1 1 All MD MI5404 ■ — 604.00 1 3 Plug-in Mounted List Price $ each Standard Package Complete with 0 two breakers Wt Lb Std Pkg 1 ⁄4 1 All ND MI5404 ■ — 604.00 1 3 All PD, RD MI5405▲ — 694.00 — — STD STDMIF32▲ — 4036.00 — — Mechanical Interlock MI5444 ■ Built to order. Allow 2–3 weeks for delivery. With Each ▲ Built to order. Allow 6–8 weeks for delivery. Addition Mechanical Note: CSO = Consult Sales Office Kit consists of 4 screws and washers. Consists of 1 screw and washers (order 100). Consists of 1 screw and washers (order 50). Discount Schedule MCCB I0204ML1125 6 ⁄4 mechanical interlock in place, no accessory can be installed into circuit breaker right pole. of the mechanical interlock will prevent accessory installation in the left pole. Sold only in standard package quantities. Multiply List Price Each times package quantity for full price. package contains 5 strips of 6 each. Each strip can be broken at perforations for 1, 2 or 3-pole use. interlock is not designed for use within Siemens panelboards. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-87 Molded Case Circuit Breakers External Accessories Selection Rotary Door Mounted Operating Handles Types 1, 3, 3R , 12, 4 4X Complete Mechanism For Use Catalog Number With Breaker Standard Variable Frames Depth Depth Handle Only Breaker Operator Shaft Only List Catalog List Catalog Price $ Number Price $ Number EG RHVE64X RHVE124X 225.00 — ED CRHOESD CRHOEVD 159.00 FD CRHOFSD CRHOFVD — List Length Catalog Price $ (inches) Number — — RHOEBO 76.00 — 2 RHOFBO 131.00 213.00 12 CRHOH 51.00 JD, LD CRHOJSD CRHOJVD 295.00 RHOJBO 212.00 16 LMD CRHOLMSD CRHOLMVD 295.00 RHOLMBO 212.00 MD, ND RHONSD PD, RD RHONVD 452.00 RHOH List Price $ — — RHOSSD 31.50 RHOSVD 31.50 RHOSXD 31.50 RHONSSD▲ 97.00 RHONSVD 97.00 RHONSXD 127.00 3 116.00 RHONBO 239.00 12 24 CRHOH RHOH Rotary Door Mounted Operating Handles Types 1 & 12 Standard Depth Variable Depth Handle and Shaft Breaker Operator For Use With Catalog Breaker Frames Number List Catalog Price $ Number List Price $ Catalog Number List Price $ Catalog Number CQD, NGG — ED D11CEU1 — RHOCQVD 145.00 RHOH62 55.00 CQDOP 90.00 160.00 D11CEU2 — — — — FD D11CFU1▲ 198.00 D11CFU2 239.00 — — — — JD, LD — D11CJU2 339.00 — — — — — 183.00 List Price $ D11CEU2 For CQD and NGG red emergency handle, order assembly RHOCQVDE (includes handle and operator). For CQD and NGG in a NEMA 3R enclosure, order CQDOP34 operator ($90.00), RHOH handle and RHOSVD shaft. For CQD and NGG in a NEMA 4 or 4X enclosure, order CQDOP34 operator, RHOH4 handle and RHOSVD shaft. Through Door Mounted Operating Handles Rotary Door Mounted Operating Handles Types 1 & 12 MOLDED CASE CIRCUIT BREAKERS 6 Standard Depth Variable Depth For Use With Breaker Frames Catalog Number List Price $ Catalog Number CQD, NGG FMHOS — — QJ OH9498 ■ 139.00 VH9499 218.00 EG RHFESD 155.00 — — EG (red handle) RHFESDEM 155.00 — — ED E2RH1 155.00 E2RHV9 221.00 FD F6RH1 155.00 F6RHV9 221.00 90.00 List Price $ Standard Depth F6RH1 Door Latch Kits Catalog Number Right Hand Type List Price $ Catalog Number Left Hand List Price $ 2 point latch DKR2 338.00 DKL2■ 338.00 3 point latch DKR3 377.00 DKL3■ 377.00 Variable Depth Rotary Handle RHOCQVD ■ Built to order. Allow 2–3 weeks for delivery. ▲ Built to order. Allow 6–8 weeks for delivery. For use on 3-pole ED frame only. 6-88 F6RHV9 Meets the requirements of NFPA 79, section 5.3.3.1 for locking external operator disconnecting devices. 3 or 3R, order shaft and breaker operator as shown, and handle RHOH. For 4 & 4X, order handle RHOH4. List Price $150.00. Consult sales office for additional EG operator shaft lengths. For extended shaft support order catalog number RHONSB2. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers External Accessories Selection Max-Flex™, Flange Mounted Variable Depth Operators 햴 Complete Kit Handle Only List Price $ List Price $ Frames NEMA Type EG 1, 3 (R), MFKE3햵 12 528.00 — — 4 (x) 606.00 — — 1, 3 (R), FHOE036 햲 12 630.00 FHOH 315.00 4 (x) — 432.00 ED FD JD, LD, SJD, SLD LMD Catalog Number Breaker Operator MFKE4X3 — Catalog Number FHOH4 1, 3 (R), FHOF036 12 699.00 FHOH 315.00 4 (x) — 432.00 — FHOH4 1, 3 (R), FHOJ036 12 742.00 FHOH 315.00 4 (x) — 432.00 — FHOH4 1, 3 (R), FHOLM036 741.00 FHOH 12 315.00 4 (x) FHOH4 432.00 958.00 FHOHN 470.00 — — 1, 3 (R), MD, ND, FHON048 12 PD, RD, SMD, SND, 4 (x) — SPD Catalog Number List Price $ Catalog Number List Price $ — — — — FHOHN4 Handle Breaker Operator FHOEBO햲 161.00 FHOEC036 153.00 Max Flex ™ FHOFBO 222.00 FHOFC036 161.00 FHOJBO 249.00 FHOJC036 177.00 FHOLMBO 249.00 FHOJC036 177.00 FHONBO — Cable 36" Cable 햳 251.00 FHONC048 237.00 630.00 Max-Flex™ handles are available with solid black handles instead of the customary “red for on” flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter “i” to the catalog number (e.g. FHOHI). Alternate Length Cable Only ED FD JD/LD/LMD MD/ND/PD/RD List Catalog Price $ Number List Catalog Price $ Number List Price $ 048 060 072 084 096 120 144 182.00 203.00 224.00 249.00 275.00 376.00 417.00 192.00 217.00 239.00 264.00 287.00 376.00 417.00 209.00 239.00 275.00 277.00 376.00 408.00 424.00 237.00 275.00 320.00 337.00 401.00 437.00 588.00 FHOEC048 FHOEC060 FHOEC072 FHOEC084▲ FHOEC096 FHOEC120▲ FHOEC144▲ FHOFC048 FHOFC060 FHOFC072 FHOFC084▲ FHOFC096 FHOFC120 FHOFC144▲ FHOJC048 FHOJC060 FHOJC072 FHOJC084▲ FHOJC096 FHOJC120▲ FHOJC144▲ FHONC048 FHONC060 FHONC072 FHONC084▲ FHONC096 FHONC120▲ FHONC144▲ MOLDED CASE CIRCUIT BREAKERS List Catalog Price $ Number 6 Catalog Inches Number Handle Auxiliary Switch For use with Max-Flex and Rotary Door operators (FHOH and RHOH). 1 NO and 1 NC contact (Form C). For Use With Catalog Number List Price $ ED, FD, JD, LD, LMD, ND, PD, RD, SD, Max Flex HAS1 187.00 Fixed Depth Flange Mounting Frames Minimum Enclosure Depth ED 6.44 FD 6.44 Left Hand Mount NEMA Type Right Hand Mount Catalog Number List Price $ Catalog Number List Price $ 1, 3R, 12 FDFBEL▲ 275.00 FDFBER▲ 275.00 4, 4X FDFBEL4▲ 368.00 FDFBER4▲ 368.00 1, 3R, 12 FDFBFL▲ 294.00 FDFBFR▲ 294.00 4, 4X FDFBFL4▲ 391.00 FDFBFR4▲ 391.00 Max-Flex™ handles are available with solid black handles instead of the customary “Red for On” flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter “i” to the catalog number (e.g. FHOHI). ▲ Built to order. Allow 6–8 weeks for delivery. 햲 For 1- or 2-pole breaker order FHOED036 complete kit or FHOEDBO breaker operator only. Use MFHM3R handle. Discount Schedule MCCB 햳 48 inch cable is standard length for M through R frame Max-Flex operators. 햴 Meets requirements of NFPA 79, section 5.3.3.1 for locking external operator disconnecting devices FDFBFR 햵 Consult sales office for additional cable lengths for EG Flex Shaft Operators. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-89 Molded Case Circuit Breakers External Accessories Selection/Dimensions NEG, HEG Motor Operators Breaker Frame Voltage Catalog Number List Price $ EG 120/240AC, 125VDC SEAER 1510.00 Consult Sales Office for availability. Telemand® Motor Operator Breaker Frame ED except CED AC Voltage Hinged to Open Down List Price $ 120 MOE6120 3375.00 240 MOE6240 ▲ 3672.00 ED motor operator opens downward. Breaker Frame DC Voltage Hinged to Open Right List Price $ AC Voltage Hinged to Open Right List Price $ FD 24 48 125 MOF6024DC▲ MOF6048DC▲ MOF6125DC▲ 3549.00 3549.00 3686.00 120 240 MOF6120 MOF6240 3447.00 3875.00 JD, LD 24 48 125 MOJ6024DC▲ MOJ6048DC▲ MOJ6125DC▲ 4507.00 4507.00 4643.00 120 240 MOJ6120 MOJ6240 4460.00 4460.00 LMD 24 48 125 MOLMD6024DC▲ MOLMD6048DC▲ MOLMD6125DC▲ 4507.00 4507.00 4643.00 120 240 MOLMD6120 MOLMD6240 4460.00 4460.00 MD, ND, PD, RD — — — — — — 120 240 MOMN6120 MOMN6240 5038.00 5038.00 Telemand Motor Operator FD, JD, LD, LMD, MD, ND, PD, RD Frames To order FD through RD motor operators with Left side hinges, add “L” to catalog number (e.g. MOF6120L). List prices are the same.▲ MOLDED CASE CIRCUIT BREAKERS 6 Dimensions Frame B C D E ED A 7.04 4.31 — 4.31 13.84 F 8.84 FD 9.50 4.55 1.60 6.84 9.70 7.58 JD, LD, LMD 11.00 7.50 0.79 8.34 9.85 7.74 MD, ND, PD, RD 16.00 9.00 — 9.83 13.13 10.13 Front View Operating Currents On Catalog Number In-Rush (Amps) MOE6120 MOE6240 10.25 5.2 MOF6120/L MOF6240/L Off Running (Amps) Time (msec) In-Rush (Amps) Running (Amps) Time (msec) Reset (Amps) 2.3 1.1 550 500 10 5 2.3 1 400 330 2.3 1.1 13.6 7.6 5.5 3.5 200 200 13.6 7.6 5.5 3.5 175 185 5.5 3.5 MOLMD6120/L 13.6 6 210 13.6 6 185 6 MOJ6120/L MOJ6240/L 13.6 7.6 6 3.5 210 217 13.6 7.6 6 3.5 185 185 6 3.5 MOMN6120/L MOMN6240/L 30.2 14.7 13.2 6 240 260 30.2 14.7 13.2 6 210 230 13.2 6 E Bottom View For inches / millimeters conversion, see Application Data section. ▲ Built to order. Allow 6–8 weeks for delivery. 6-90 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers External Accessories Selection Plug-In Mounting Assemblies, Including Base and Tulip Assemblies — — PCBERC4햷 402.00 — — 2 PC2637▲ 109.00 PC2638▲ 109.00 3 PC2657 176.00 PC2658 176.00 2 PC2637▲ 109.00 PC2638▲ 109.00 3 PC2657 176.00 PC2658 176.00 2 PC4753▲ 265.00 PC4753▲ 265.00 3 PC4754 345.00 PC4754 345.00 2 PC4753▲ 265.00 PC4753▲ 265.00 3 PC4754 345.00 PC4754 345.00 All JD except CJD 2 PC5777▲ 356.00 PC5777▲ 356.00 3 PC5778 589.00 PC5778 589.00 Kit CJD, SCJD 3 PCCJD 640.00 PCCJD 640.00 All LD except CLD 2 PC5660▲ 667.00 PC5660▲ 667.00 3 PC5661 933.00 PC5661 933.00 984.00 PCCLD 984.00 Kit CLD, SCLD All MD All ND 3 PCCLD 2 PC5662▲ 1227.00 PC5662▲ 1227.00 3 PC5663 1499.00 PC5663 1499.00 2 PC5664햴▲ 1696.00 PC5664햴▲ 1696.00 3 PC5666 햴 PC5666 햴 1955.00 1955.00 PL2616 PL2617 PL4762 PL4763 PL5796 PL5797 Tulip Assemblies Switchboard Mounting Plate PL5680 PL5797 PL9698 PL9699 Tulip Assemblies Separately RS4755 3-Pole RS4756 List Price $ ED TCE2▲ 137.00 TCE3▲ 206.00 FD TCF2▲ 206.00 TCF3▲ 308.00 JD TCJ2▲ 238.00 TCJ3▲ 345.00 LD TCL2▲ 274.00 TCL3▲ 410.00 MD TCM2▲ 308.00 TCM3▲ 457.00 ND TCN2▲ 410.00 TCN3▲ 479.00 ➝ Catalog Number Circuit Breaker With Rear-Connecting Studs Rear-Connecting Studs For Use With Breaker Frames Ampere Rating Description Extension Behind Breaker (inches) Line Side Load Side Catalog Number List Price $ 햵 Catalog Number List Price $ 햵 All EG 125 125 Short Long 3.60 6.00 RTLESR RTLELR 43.00 51.00 RTLESR RTLELR 43.00 51.00 All ED 100 100 100 100 Line Side (Short) Load Side (Short) Line Side (Long) Load Side (Long) 2.38 2.38 4.88 4.88 RS2643햶▲ — RS2641햶▲ — 45.00 — 54.00 — — RS2644햶▲ — RS2642햶▲ — 45.00 — 54.00 All FD 250 250 Short Long 3.12 7.06 RS4756햶▲ RS4755햶▲ 65.00 102.00 RS4756햶▲ RS4755햶▲ 65.00 102.00 All JD 400 400 Short Long 5.85 11.20 RS5774▲ RS5773▲ 180.00 180.00 RS5774▲ RS5773▲ 180.00 180.00 All LD 600 600 Short Long 5.85 11.20 RS5784▲ RS5783▲ 214.00 203.00 RS5784▲ RS5783▲ 214.00 203.00 CJD, SCJD CLD, SCLD Add required shield kit. CLRSJL3 51.00 LM(X)D6, HLM(X)D6 800 Short Long 5.85 11.20 RS5788▲ RS5787▲ 332.00 313.00 RS5788▲ RS5787▲ 332.00 313.00 1200 1200 Short Long 5.50 8.00 RS5786▲ RS5785▲ 258.00 326.00 RS5786▲ RS5785▲ 258.00 326.00 All MD, ND ▲ Built to order. Allow 6–8 weeks for delivery. 햲 Furnished at no extra charge when ordered with plug-in mounting assembly. 햳 Each piece catalog number consists of (1) mounting block assembly and required tulip assemblies (2) for 2-pole, (3) for 3-pole Discount Schedule MCCB 햴 For vertical bus mounting — for horizontal, substitute PC5665 for PC5664 and PC5667 for PC5666. includes one current stud, insulating tube, stud nuts and terminal shields, when required. 햵 Price 햶 For proper electrical clearance, studs must alternate between short and long stud lengths on circuit breaker poles (e.g. SLSLSL or LSLSLS). 햷 Plug-in assembly for EG breakers include line and load side in one assembly. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-91 MOLDED CASE CIRCUIT BREAKERS List Price $ 6 Catalog Number ➝ 2-Pole For Frame ➝ CFD — ➝ ➝ 352.00 4 ➝ PCBERC3햷 ➝ 3 Base Steel Switchboard Mounting Plate 햲 Catalog Number ➝ All FD except CFD List Price $ ➝ CED Catalog Number햳 ➝ All ED except CED Poles List Price $ ➝ EG Load Side Catalog Number햳 ➝ Line Side For Use With Breaker Frames Siemens VL Circuit Breakers Technical Overview Technical Frame Summary and Ratings Table Frame Family DG 30 to 150A 40 to 250A 70 to 400A Number of Poles 2,3 2,3 2,3 Type of Protection Thermal-Magnetic Electronic Electronic with LCD Motor Circuit Protector Molded Case Switch 100% Rated Breaker 50°C Calibrated Breaker햳 Interchangeable Trip Unit W In.(mm) H D D2 6 JG Continuous Ampere Range Maximum Voltage Rating MOLDED CASE CIRCUIT BREAKERS FG 4 4 600V 600V ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ — — ◆ ◆ ◆ ◆ 4.1 (105) 2, 3-pole / 5.5 (139) 4-pole 7.3 (175) 3.4 (81) 4.2 (107) Type N – Normal Interrupting Rating햲, RMS Symmetrical Amperes (kA) 240Vac 65 65 UL 480Vac 35 35 600Vac 18 18 240Vac 65/65 65/65 IEC 415Vac 40/40 40/40 (lCU /lCS) — — — 690Vac 12/6 12/6 DC Voltages – Interrupting Rating (kA)햵 250Vdc - 2p 500Vdc - 3p햴 600Vdc - 3p 750Vdc - 4p햳 30 18 — — 30 18 — — Type H – High Interrupting Rating햲, RMS Symmetrical Amperes (kA) 240Vac 100 100 UL 480Vac 65 65 600Vac 20 20 240Vac 100/75 100/75 IEC 415Vac 70/70 70/70 (lCU /lCS) — — — 690Vac 12/6 12/6 DC Voltages – Interrupting Rating (kA)햵 250Vdc - 2p 500Vdc - 3p햴 600Vdc - 3p 750Vdc - 4p햳 30 18 — — 30 18 — — Type L – Very High Interrupting Rating햲, RMS Symmetrical Amperes (kA) 240Vac 200 200 UL 480Vac 100 100 600Vac 25 25 240Vac 200/150 200/150 IEC 415Vac 100/75 100/75 (lCU /lCS) — — — 690Vac 12/6 12/6 DC Voltages – Interrupting Rating (kA)햵 250Vdc - 2p 500Vdc - 3p햴 600Vdc - 3p 750Vdc - 4p햳 햲 30 18 — — UL does not recognize AIC ratings for Molded Case Switches or Motor Circuit Protectors. 햳 Not UL. 6-92 4 600V 30 30 — — 햴 5.5 (139) 7.2 (183) 11 (279) 4.2 (102) 5.4 (138) 65 35 25 65/65 45/45 — 12/6 30 25 — — 100 65 25 100/75 70/70 — 15/8 30 35 — — 200 100 25 200/150 100/75 — 15/8 30 35 — — 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햵 DC Interruption Ratings do not apply to electronic trip circuit breakers. Siemens VL Circuit Breakers Technical Overview Technical Frame Summary and Ratings Table — Continued Frame Family Continuous Ampere Range LG 150 to 600A Number of Poles NG 200 to 800A 2, 3 Maximum Voltage Rating 2,3 4 2,3 400 to 1600A 4 3 4 600V 600V ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ 5.5 (139) 11 (279) 4.2 (102) 5.4 (138) 7.5 (190) 10 (253) 16 (406) 4.7 (114) 5.9 (151) — 22 35 — — Type H – High Interrupting Rating햲, RMS Symmetrical Amperes (kA) 240Vac 100 100 UL 480Vac 65 65 600Vac 25 35 240Vac 100/75 100/75 IEC 415Vac 70/70 70/70 (lCU /lCS) — — — 690Vac 15/8 30/15 DC Voltages – Interrupting Rating (kA)햵 250Vdc - 2p 500Vdc - 3p햴 600Vdc - 3p 750Vdc - 4p햳 30 35 — — 25 50 — — Type L – Very High Interrupting Rating햲, RMS Symmetrical Amperes (kA) 240Vac 200 200 UL 480Vac 100 100 600Vac 25 50 240Vac 200/150 200/150 IEC 415Vac 100/75 100/75 (lCU /lCS) — — — 690Vac 15/8 35/17 DC Voltages – Interrupting Rating (kA)햵 250Vdc - 2p 500Vdc - 3p햴 600Vdc - 3p 750Vdc - 4p햳 30 35 — — UL does not recognize AIC ratings for Molded Case Switches or Motor Circuit Protectors. Not UL. 42 65 — — 햴 9 (229) 2, 3-pole / 12 (305) 4-pole 16 (406) 6.2 (157) 8.1 (207) 65 35 25 65/65 50/25 — 20/10 65 35 25 65/65 50/25 — 20/10 22 35 — — 22 35 — — 100 65 35 100/75 70/35 — 30/15 100 65 35 100/50 70/35 — 30/15 25 50 — — 25 50 — — 200 100 65 200/150 100/75 — 35/17 200 100 65 200/150 100/75 — 35/17 42 65 — — 42 65 — — 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. 햵 MOLDED CASE CIRCUIT BREAKERS 30 25 — — — ◆ ◆ ◆ ◆ 6 DC Voltages – Interrupting Rating (kA)햵 250Vdc - 2p 500Vdc - 3p햴 600Vdc - 3p 750Vdc - 4p햳 햳 300 to 1200A 600V Type N – Normal Interrupting Rating햲, RMS Symmetrical Amperes (kA) 240Vac 65 65 UL 480Vac 35 35 600Vac 25 25 240Vac 65/65 65/65 IEC 415Vac 45/45 50/50 (lCU /lCS) — — — 690Vac 12/6 20/10 햲 PG 600V Type of Protection Thermal-Magnetic Electronic Electronic with LCD Motor Circuit Protector Molded Case Switch 100% Rated 50°C Calibrated Breaker햳 Interchangeable Trip Unit W In.(mm) H D D2 MG DC Interruption Ratings do not apply to electronic trip circuit breakers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-93 VL Circuit Breakers Trip Unit Overview Selection mation menus. With precise control over the circuit beaker functions and access to system status, diagnostics, and information, these trip units allow for unsurpassed flexibility in circuit coordination. The interchangeability of the VL circuit breaker trip units allow for easy conversion from any of 3 types of protection. They are thermal-magnetic, electronic, or electronic with a built-in LCD display. The thermal-magnetic trip unit features an adjustable magnetic trip setting. The electronic trip units are microprocessor based true RMS sensing devices and are available with a variety of adjustable trip settings, configurations, and infor- An example of coordination is the out of the box Ground Fault function on the Model 545 trip units. The pick-up and time delay settings are fixed for each frame and do not overlap with the settings on the other frames. Therefore, when VL breakers are used together in a system the GF protection is automatically coordinated. The user also has the ability to program a custom coordination scheme with the high level of adjustability available on the Model 576 trip units. VL Trip Units Trip Unit Functions Model 576 Electronic LI Electronic LIG Electronic LSI Electronic LSIG Electronic with LCD LSI Electronic with LCD LSIG Continuous Current Setting (Ir) Fixed ◆ ◆ ◆ ◆ ◆ ◆ Long Time Delay (tr) 䊐 ◆ ◆ Fixed Fixed ◆ ◆ Instantaneous Overcurrent Setting (Ii) ◆ ◆ ◆ Fixed Fixed ◆ ◆ Short Time Pick-up (Isd) 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 ● 䊐 䊐 䊐 䊐 䊐 䊐 䊐 䊐 ◆ ◆ ◆ 䊐 䊐 ● 䊐 䊐 䊐 䊐 䊐 ◆ ◆ ◆ (ON/OFF) (ON/OFF) ◆ ◆ 䊐 䊐 䊐 ● ● ● ● ● ◆ ◆ ◆ ◆ 䊐 ● ● ● ● ● Short Time l t Pick-up 2 Ground Fault Pick-up (lg) Ground Fault Delay (tg) Alarm & Status LEDs 6 Model 545 ThermalMagnetic Short Time Delay (tsd) MOLDED CASE CIRCUIT BREAKERS Model 525 Built-in Display (LCD) Pre-Trip Alarm햲 Last trip information햲 Zone Selective햲 Communications햲 Fixed Fixed ● 䊐 䊐 䊐 䊐 䊐 Fixed Fixed ● 䊐 䊐 䊐 䊐 䊐 ◆ – Adjustable setting. ● – This feature is included. “fixed” – Non-Adjustable setting. 䊐 – Feature is not included. 햲 – Requires the trip unit to be connected to a PC (via a COMPRO or COMMOD communications module) for access or programming. Continuous Amps Rating (Ir) This setting is the continuous current that the breaker will carry without tripping. It can be set up to 100% of the trip unit’s nominal rating (In). Long Time Delay (tr) Sometimes referred to as the “overload” position, this function controls the breaker‘s “pause-in-tripping” time. It allows low level, temporary inrush currents such as those encountered when starting a motor to pass without tripping. The time delay begins when the current reaches 6 x Ir. Instantaneous Pick-up (Ii) This function sets the breaker to trip instantaneously during high fault conditions. On Model 545 trip units this set6-94 ting is fixed on LSI and LSIG trip units and adjustable on LI and LIG trip units. These features are fully adjustable on Model 576 trip units. Short Time Pick-Up (lsd) This function controls the level of fault current the breaker will carry for a short time without tripping, thus allowing downstream devices to clear short circuits ahead of up-stream protection. It may be defeated (turned-off) on Model 576 trip units. Short Time Delay (tsd) This controls the interval of time the breaker will remain closed against a fault (at the Short Time Pick-up current level) without tripping. The time delay may be set at fixed points or at short time intervals based on l2t curves. This function is Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog used with the Short Time Pick-up to achieve selectivity and better system coordination. Ground Fault Pick-Up (Ig) This setting controls the level of ground fault current that will cause the breaker to trip. Model 545 Electronic Trip Units act on the residual current to sense ground current. The Model 576 Electronic Trip Unit is programmable and allows the user to select either the residual current method or direct detection (via a separate current transformer) to detect ground current. Ground Fault Time Delay (tg) This controls the interval of time the breaker will remain closed after a ground fault is detected (at the Ground Fault Pick-up current level) without tripping. VL Circuit Breakers General Information Selection Thermal-Magnetic trip units, Model 525, combine the inverse time element design for low level overloads, and instantaneous magnetic action for short circuit protection. The standard unit has preset overload protection and an adjustable instantaneous trip setting, with 6 set points. Thermal-Magnetic trip units are available throughout the VL family, from 15 to 1600A. Type/Tipo CLT3 Ii M4-PAN-TORX M4-PAN-TORX I n = 600A 3850 3300 2750 4400 40 C 4950 TM ~ 5500 Trip Unit/Disparador 525 Cat. No. CLT3B600 Electronic Trip Units Electronic trip units are available through the VL family, from 60A (which can be set as low as 30A) up through 1600A . They are also available in four trip configurations (LI, LIG, LSI, LSIG) and features can include a built-in LCD display. On the Model 545 Electronic Trip Unit a flashing LED confirms that the microprocessor in operating and another indicates an overload condition. For ease-of-use and to insure proper coordination, the set points for the continuous current are shown on the face of these trip units in amps. displays, no secondary or auxiliary voltage is required as long as the breaker is energized and a minimal load current is present. These trip units can also indicate the “last trip” status (date, time, amps) when they‘re connected to a PC via one of our communications modules. On the Model 576, the LCD version, the current in each phase is continuously shown on the display. Unlike many Typical Trip Unit Labeling and Adjustment Positions 6 Model 545 Electronic Trip Unit with LSIG trip functions MOLDED CASE CIRCUIT BREAKERS Model 576 Electronic Trip Unit has an LCD display Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-95 VL Circuit Breakers DG 150A Frame, VL Series Selection Ordering Information Complete Assembled Breaker Prices for a complete factory assembled DG breaker include the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are only available with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to “X” for standard breakers. For 50˚C and special applications, refer to page 6-144.A Mounting hardware is included with each frame or complete breaker. Interrupting Ratings Breaker Type NDG HDG LDG RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 18 30 18 65 65 40 40 100 65 20 30 18 100 75 70 70 200 100 25 30 18 200 150 100 75 690 ICU 12 12 12 ICS 6 6 6 Number of Poles 6 Connectors for 75°C Wire MOLDED CASE CIRCUIT BREAKERS Dimensions, inches (mm) Ampere Construction Rating Steel 30-150 30-150 Aluminum햲 햳 Copper 30-150 Distribution Lugs Wire Range #8–1/0 Cu #6–3/0 Al/Cu #6–3/0 Cu No. of cables per connector 1 1 1 Catalog Number 3TW1DG20햳 3TA1DG30햳 3TC1DG30햳 List Price $ 22.00 22.00 101.00 30-150 30-150 Compression Lugs 30-150 30-150 #14–#2 Cu (3pcs. Max) #14–#4 Cu 3 6 3TA3DG02햳 3TA6DG04햳 110.00 110.00 #14–2/0 kcmil Al/Cu #14–2/0 kcmil Al/Cu – – 2CLD20햴 3CLD20햵 54.00 81.00 2, 3 4 Width Length Depth 4.1 (105) 6.9 (175) 3.4 (81) 5.5 (139) To Handle D1 4.2(107) Approx. Shipping Weight, lbs. (kg) Trip Unit Complete Poles Frame Thermal-Mag. Electronic Breaker 2, 3 3.7 (1.7) 4 4.9 (2.2) 2.2 (1.0) 2.6 (1.2) 2.6 (1.2) 3.3 (1.5) 5.9 (2.7) 7.5 (3.4) 햲 Standard connector supplied with complete breakers. Kit consists of 3 terminal connectors. 2 Lugs for 2-pole breakers. 햵 3 Lugs for 3-pole breakers. 햳 햴 DG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 50 60 70 80 90 100 110 125 150 Instantaneous Overcurrent Setting (Ii) Min. Max. 450 700 450 700 450 700 450 800 500 1000 500 1000 550 1100 625 1250 800 1600 Note: Each breaker has 6 trip settings in this range. A - Consult with Siemens for availability. 6-96 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog External Accessories pages 6-125 through 6-139 Discount Schedule MCCB VL Case Circuit Breakers DG 150A Thermal-Magnetic Trip Unit Selection Ii Type / Tipo CDT3 I n =150A AMPS 1120 960 800 40? C 1280 TM ~ 1440 1600 TRIP UNIT/DISPARADOR 525 Cat. No. - CDT3B150 Model 525 Trip Unit DG 150A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Catalog Number Continuous Ampere Rating 50 60 70 80 90 100 110 125 150 NDG2F150 List Price $ 618.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HDG2F150 1533.00 L-Interrupting Class Catalog Number LDG2F150 List Price $ 1002.00 1002.00 1074.00 1074.00 1074.00 1074.00 2234.00 2234.00 2234.00 HDG2B050L HDG2B060L HDG2B070L HDG2B080L HDG2B090L HDG2B100L HDG2B110L HDG2B125L HDG2B150L 1917.00 1917.00 1989.00 1989.00 1989.00 1989.00 3149.00 3149.00 3149.00 LDG2B050L LDG2B060L LDG2B070L LDG2B080L LDG2B090L LDG2B100L LDG2B110L LDG2B125L LDG2B150L List Price $ 2664.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NDG2B050L NDG2B060L NDG2B070L NDG2B080L NDG2B090L NDG2B100L NDG2B110L NDG2B125L NDG2B150L Catalog Number TRIP UNIT ONLY 3048.00 3048.00 3120.00 3120.00 3120.00 3120.00 4280.00 4280.00 4280.00 CDT2B050 CDT2B060 CDT2B070 CDT2B080 CDT2B090 CDT2B100 CDT2B110 CDT2B125 CDT2B150 355.00 355.00 427.00 427.00 427.00 427.00 1587.00 1587.00 1587.00 Catalog Number List Price $ DG 150A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class 50 60 70 80 90 100 110 125 150 NDG3F150 768.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HDG3F150 1796.00 L-Interrupting Class Catalog Number LDG3F150 List Price $ 2948.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NDG3B050L NDG3B060L NDG3B070L NDG3B080L NDG3B090L NDG3B100L NDG3B110L NDG3B125L NDG3B150L 1227.00 1227.00 1344.00 1344.00 1344.00 1344.00 2793.00 2793.00 2793.00 HDG3B050L HDG3B060L HDG3B070L HDG3B080L HDG3B090L HDG3B100L HDG3B110L HDG3B125L HDG3B150L 2255.00 2255.00 2372.00 2372.00 2372.00 2372.00 3821.00 3821.00 3821.00 LDG3B050L LDG3B060L LDG3B070L LDG3B080L LDG3B090L LDG3B100L LDG3B110L LDG3B125L LDG3B150L TRIP UNIT ONLY 3407.00 3407.00 3524.00 3524.00 3524.00 3524.00 4973.00 4973.00 4973.00 CDT3B050 CDT3B060 CDT3B070 CDT3B080 CDT3B090 CDT3B100 CDT3B110 CDT3B125 CDT3B150 416.00 416.00 533.00 533.00 533.00 533.00 1982.00 1982.00 1982.00 Catalog Number List Price $ DG 150A Frame 4-Pole with Thermal-Magnetic Trip Unit A N-Interrupting Class Catalog Number Continuous Ampere Rating 50 60 70 80 90 100 110 125 150 NDG4F150 List Price $ 998.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HDG4F150 2335.00 L-Interrupting Class Catalog Number LDG4F150 List Price $ 3833.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NDG4B050L NDG4B060L NDG4B070L NDG4B080L NDG4B090L NDG4B100L NDG4B110L NDG4B125L NDG4B150L 1597.00 1597.00 1750.00 1750.00 1750.00 1750.00 3634.00 3634.00 3634.00 HDG4B050L HDG4B060L HDG4B070L HDG4B080L HDG4B090L HDG4B100L HDG4B110L HDG4B125L HDG4B150L 2934.00 2934.00 3087.00 3087.00 3087.00 3087.00 4971.00 4971.00 4971.00 LDG4B050L LDG4B060L LDG4B070L LDG4B080L LDG4B090L LDG4B100L LDG4B110L LDG4B125L LDG4B150L TRIP UNIT ONLY 4432.00 4432.00 4585.00 4585.00 4585.00 4585.00 6469.00 6469.00 6469.00 CDT4B050 CDT4B060 CDT4B070 CDT4B080 CDT4B090 CDT4B100 CDT4B110 CDT4B125 CDT4B150 541.00 541.00 694.00 694.00 694.00 694.00 2578.00 2578.00 2578.00 A - Consult with Siemens for availability. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-97 MOLDED CASE CIRCUIT BREAKERS Continuous Ampere Rating List Price $ 6 Catalog Number VL Circuit Breakers DG 150A Electronic 3-Knob & LCD Trip Units Selection Model 545 Trip Units DG 150A Frame 3-Pole Electronic Trip Unit N-Interrupting Class Catalog Number Continuous Ampere Rating NDG3F150 List Price $ 768.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HDG3F150 1796.00 L-Interrupting Class Catalog Number List Price $ LDG3F150 2948.00 Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NDG3N060L NDG3N100L NDG3N150L 1591.00 1709.00 3157.00 60 100 150 NDG3P060L NDG3P100L NDG3P150L 1925.00 2043.00 3492.00 60 100 150 NDG3U060L NDG3U100L NDG3U150L 3806.00 3923.00 5372.00 60 100 150 NDG3X060L NDG3X100L NDG3X150L 3472.00 3590.00 5038.00 TRIP UNIT ONLY LDG3N060L LDG3N100L LDG3N150L 3771.00 3889.00 5337.00 CDT3N060 CDT3N100 CDT3N150 780.00 898.00 2346.00 LDG3P060L LDG3P100L LDG3P150L 4105.00 4223.00 5672.00 CDT3P060 CDT3P100 CDT3P150 1114.00 1232.00 2681.00 LDG3U060L LDG3U100L LDG3U150L 5986.00 6103.00 7552.00 CDT3U060 CDT3U100 CDT3U150 2995.00 3112.00 4561.00 LDG3X060L LDG3X100L LDG3X150L 5652.00 5770.00 7218.00 CDT3X060 CDT3X100 CDT3X150 2661.00 2779.00 4227.00 Catalog Number List Price $ MOLDED CASE CIRCUIT BREAKERS 6 60 100 150 ELECTRONIC LI TRIP HDG3N060L 2619.00 HDG3N100L 2737.00 HDG3N150L 4185.00 ELECTRONIC LSI TRIP HDG3P060L 2953.00 HDG3P100L 3071.00 HDG3P150L 4520.00 ELECTRONIC LSIG TRIP HDG3U060L 4834.00 HDG3U100L 4951.00 HDG3U150L 6400.00 ELECTRONIC LIG TRIP HDG3X060L 4500.00 HDG3X100L 4618.00 HDG3X150L 6066.00 List Price $ Model 576 Trip Unit DG 150A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class Catalog Number Continuous Ampere Rating 6-98 NDG3F150 List Price $ 768.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HDG3F150 1796.00 L-Interrupting Class Catalog Number List Price $ LDG3F150 2948.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 60 100 150 NDG3D060L NDG3D100L NDG3D150L 2092.00 2226.00 3894.00 60 100 150 NDG3E060L NDG3E100L NDG3E150L 3974.00 4108.00 5775.00 LCD ELECTRONIC LSI TRIP HDG3D060L 3120.00 HDG3D100L 3254.00 HDG3D150L 4922.00 LCD ELECTRONIC LSIG TRIP HDG3E060L 5002.00 HDG3E100L 5136.00 HDG3E150L 6803.00 TRIP UNIT ONLY LDG3D060L LDG3D100L LDG3D150L 4272.00 4406.00 6074.00 CDT3D060 CDT3D100 CDT3D150 1281.00 1415.00 3083.00 LDG3E060L LDG3E100L LDG3E150L 6154.00 6288.00 7955.00 CDT3E060 CDT3E100 CDT3E150 3163.00 3297.00 4964.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB VL Circuit Breakers Internal Accessories for DG 150A and FG 250A Frames Selection Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/B햴 Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switch 1A + 1B, 1A/B햴 Bases AMBL2 & AMBL3 Mounting Pocket햲 Catalog Number List Price $ Left, Right햳 ASKL1 265.00 Left, Right, Neutral ASKL2 265.00 Left, Right햳 ASKL3 530.00 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right, Neutral Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 List Price $ 61.00 61.00 61.00 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB List Price $ 108.00 108.00 Shunt Trips Mounting Pocket Right Pocket Only List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 MOLDED CASE CIRCUIT BREAKERS Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 6 Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC 600 VAC Mounting Pocket Right Pocket Only Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 UVRLV600 List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 ‘A’ refers to a normally open contact (open when the breaker contacts are open). ‘B’ refers to a normally closed contact (closed when the breaker contacts are open). 햲 Refer to the “Accessory Locations” chart for guidelines and limitations about which pockets may be used for accessory combinations. 햳 These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right. 햴 Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. Discount Schedule MCCB External Accessories pages 6-125 through 6-139 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-99 VL Circuit Breakers FG 250A Frame, VL Series Selection/Dimensions Ordering Information Complete Assembled Breaker Prices for a complete factory assembled FG breaker include the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to “X” for standard breakers. For 50˚C and special applications, refer to page 6-144.A Mounting hardware is included with each frame or complete breaker. Number of Poles Interrupting Ratings Breaker Type NFG HFG LFG RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 18 30 18 65 65 40 40 100 65 20 30 25 100 75 70 70 200 100 25 30 30 200 150 100 75 2, 3 4 6 Width Length Depth To Handle D1 4.1 (105) 6.9 (175) 3.4 (81) 4.2 (107) 5.5 (139) Shipping Weight, lbs. (kg) 690 ICU 12 12 12 ICS 6 6 6 Trip Unit Poles Frame 2, 3 4.0 (1.8) 4 5.3 (2.4) Thermal-Mag. Electronic Complete Breaker 2.2 (1.0) 2.6 (1.2) 2.6 (1.2) 3.3 (1.5) 6.2 (2.8) 7.9 (3.6) EnclosuresA Connectors for 75°C Wire MOLDED CASE CIRCUIT BREAKERS Dimensions, inches (mm) Ampere Construction Rating Steel 50-250 50-250 Aluminum햲 Copper 50-250 Distribution Lugs Wire Range #4–350 kcmil Cu #4–350 kcmil Al/Cu #4–350 kcmil Cu No. of cables per connector 1 1 1 Catalog Number 3TW1FG350햳 3TAW1FG350햳 3TCW1FG350햳 List Price $ 65.00 65.00 104.00 50-250 50-250 Compression Lugs 50-250 50-250 #12–2/0 Cu #14–#4 Cu 3 6 3TA3FG20햳 3TA6FG04햳 110.00 110.00 #6–350 kcmil Al/Cu #6–350 kcmil Al/Cu – – 2CLF350햴 3CLF350햵 102.00 152.00 NEMA Class Catalog Number List Price $ 1 (Flush) 1 (Surface) 1 (Surface) 3R 4 – 4X 7-9 12 Neutral FG0251F FG0221S (225A max) FG0251S (250A) FG0253R FG0254S FG02579 FG02512 (future) CSO CSO CSO CSO CSO CSO CSO — 햲 Standard connector supplied with complete breakers. Kit consists of 3 terminal connectors. 2 Lugs for 2-pole breakers. 햵 3 Lugs for 3-pole breakers. 햳 햴 FG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 100 110 125 150 175 200 225 250 Instantaneous Overcurrent Setting (Ii) Min. Max. 625 800 800 800 1000 1000 1250 1250 1250 1600 1600 1600 2000 2000 2500 2500 Note: Each breaker has 6 trip settings in this range. A - Consult with Siemens for availability. 6-100 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog External Accessories pages 6-125 through 6-139 Discount Schedule MCCB VL Circuit Breakers FG 250A Thermal-Magnetic Trip Unit Selection Ii Type / Tipo CFT3 I n =250A AMPS 1750 1500 40? C 2000 TM ~ 2250 1250 2500 TRIP UNIT/DISPARADOR 525 Cat. No. - CFT3B250 Model 525 Trip Unit FG 250A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating 100 110 125 150 175 200 225 250 H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NFG2F250 1128.00 FRAME ONLY HFG2F250 2994.00 L-Interrupting Class Catalog Number LFG2F250 List Price $ 2374.00 2374.00 2374.00 2374.00 2374.00 2374.00 2374.00 2999.00 HFG2B100L HFG2B110L HFG2B125L HFG2B150L HFG2B175L HFG2B200L HFG2B225L HFG2B250L 4240.00 4240.00 4240.00 4240.00 4240.00 4240.00 4240.00 4865.00 LFG2B100L LFG2B110L LFG2B125L LFG2B150L LFG2B175L LFG2B200L LFG2B225L LFG2B250L List Price $ 4505.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NFG2B100L NFG2B110L NFG2B125L NFG2B150L NFG2B175L NFG2B200L NFG2B225L NFG2B250L Catalog Number TRIP UNIT ONLY 5751.00 5751.00 5751.00 5751.00 5751.00 5751.00 5751.00 6376.00 CFT2B100 CFT2B110 CFT2B125 CFT2B150 CFT2B175 CFT2B200 CFT2B225 CFT2B250 1158.00 1158.00 1158.00 1158.00 1158.00 1158.00 1158.00 1783.00 Catalog Number List Price $ FG 250A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Catalog Number List Price $ NFG3F250 1388.00 FRAME ONLY HFG3F250 3493.00 L-Interrupting Class Catalog Number LFG3F250 List Price $ 4971.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NFG3B100L NFG3B110L NFG3B125L NFG3B150L NFG3B175L NFG3B200L NFG3B225L NFG3B250L 2882.00 2882.00 2882.00 2882.00 2882.00 2882.00 2882.00 3617.00 HFG3B100L HFG3B110L HFG3B125L HFG3B150L HFG3B175L HFG3B200L HFG3B225L HFG3B250L 4987.00 4987.00 4987.00 4987.00 4987.00 4987.00 4987.00 5722.00 LFG3B100L LFG3B110L LFG3B125L LFG3B150L LFG3B175L LFG3B200L LFG3B225L LFG3B250L TRIP UNIT ONLY 6465.00 6465.00 6465.00 6465.00 6465.00 6465.00 6465.00 7200.00 CFT3B100 CFT3B110 CFT3B125 CFT3B150 CFT3B175 CFT3B200 CFT3B225 CFT3B250 1362.00 1362.00 1362.00 1362.00 1362.00 1362.00 1362.00 2097.00 Catalog Number List Price $ FG 250A Frame 4-Pole with Thermal-Magnetic Trip UnitA N-Interrupting Class Continuous Ampere Rating 100 110 125 150 175 200 225 250 H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NFG4F250 1805.00 FRAME ONLY HFG4F250 4542.00 L-Interrupting Class Catalog Number LFG4F250 List Price $ 6463.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NFG4B100L NFG4B110L NFG4B125L NFG4B150L NFG4B175L NFG4B200L NFG4B225L NFG4B250L 3752.00 3752.00 3752.00 3752.00 3752.00 3752.00 3752.00 4707.00 HFG4B100L HFG4B110L HFG4B125L HFG4B150L HFG4B175L HFG4B200L HFG4B225L HFG4B250L 6489.00 6489.00 6489.00 6489.00 6489.00 6489.00 6489.00 7444.00 LFG4B100L LFG4B110L LFG4B125L LFG4B150L LFG4B175L LFG4B200L LFG4B225L LFG4B250L TRIP UNIT ONLY 8410.00 8410.00 8410.00 8410.00 8410.00 8410.00 8410.00 9365.00 CFT4B100 CFT4B110 CFT4B125 CFT4B150 CFT4B175 CFT4B200 CFT4B225 CFT4B250 1771.00 1771.00 1771.00 1771.00 1771.00 1771.00 1771.00 2726.00 A - Consult with Siemens for availability. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-101 MOLDED CASE CIRCUIT BREAKERS 100 110 125 150 175 200 225 250 List Price $ 6 Continuous Ampere Rating H-Interrupting Class Catalog Number VL Circuit Breakers FG 250A Electronic 3-Knob & LCD Trip Units Selection Model 545 Trip Units FG 250A Frame 3-Pole Electronic Trip Unit N-Interrupting Class List Price $ Catalog Number List Price $ NFG3F250 1388.00 FRAME ONLY HFG3F250 3493.00 L-Interrupting Class Catalog Number List Price $ LFG3F250 4971.00 Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 100 150 250 NFG3N100L NFG3N150L NFG3N250L 3325.00 3325.00 4060.00 100 150 250 NFG3P100L NFG3P150L NFG3P250L 3659.00 3659.00 4393.00 100 150 250 NFG3U100L NFG3U150L NFG3U250L 5540.00 5540.00 6273.00 100 150 250 NFG3X100L NFG3X150L NFG3X250L 5206.00 5206.00 5941.00 ELECTRONIC LI TRIP HFG3N100L 5430.00 HFG3N150L 5430.00 HFG3N250L 6165.00 ELECTRONIC LSI TRIP HFG3P100L 5764.00 HFG3P150L 5764.00 HFG3P250L 6498.00 ELECTRONIC LSIG TRIP HFG3U100L 7645.00 HFG3U150L 7645.00 HFG3U250L 8378.00 ELECTRONIC LIG TRIP HFG3X100L 7311.00 HFG3X150L 7311.00 HFG3X250L 8046.00 List Price $ TRIP UNIT ONLY LFG3N100L LFG3N150L LFG3N250L 6908.00 6908.00 7643.00 CFT3N100 CFT3N150 CFT3N250 1805.00 1805.00 2540.00 LFG3P100L LFG3P150L LFG3P250L 7242.00 7242.00 7976.00 CFT3P100 CFT3P150 CFT3P250 2139.00 2139.00 2873.00 LFG3U100L LFG3U150L LFG3U250L 9123.00 9123.00 9856.00 CFT3U100 CFT3U150 CFT3U250 4020.00 4020.00 4753.00 LFG3X100L LFG3X150L LFG3X250L 8789.00 8789.00 9524.00 CFT3X100 CFT3X150 CFT3X250 3686.00 3686.00 4421.00 Catalog Number List Price $ MOLDED CASE CIRCUIT BREAKERS 6 Continuous Ampere Rating H-Interrupting Class Catalog Number Model 576 Trip Unit FG 250A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class Continuous Ampere Rating 6-102 H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NFG3F250 1388.00 FRAME ONLY HFG3F250 3493.00 L-Interrupting Class Catalog Number List Price $ LFG3F250 4971.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 100 150 250 NFG3D100L NFG3D150L NFG3D250L 3980.00 3980.00 4825.00 100 150 250 NFG3E100L NFG3E150L NFG3E250L 5861.00 5861.00 6705.00 LCD ELECTRONIC LSI TRIP HFG3D100L 6085.00 HFG3D150L 6085.00 HFG3D250L 6930.00 LCD ELECTRONIC LSIG TRIP HFG3E100L 7966.00 HFG3E150L 7966.00 HFG3E250L 8810.00 TRIP UNIT ONLY LFG3D100L LFG3D150L LFG3D250L 7563.00 7563.00 8408.00 CFT3D100 CFT3D150 CFT3D250 2460.00 2460.00 3305.00 LFG3E100L LFG3E150L LFG3E250L 9444.00 9444.00 10288.00 CFT3E100 CFT3E150 CFT3E250 4341.00 4341.00 5185.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB VL Circuit Breakers Internal Accessories for DG 150A and FG 250A Frames Selection Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/B햴 Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switches 1A + 1B, 1A/B햴 Bases AMBL2 & AMBL3 Mounting Pocket햲 Catalog Number List Price $ Left, Right햳 ASKL1 265.00 Left, Right, Neutral ASKL2 265.00 Left, Right햳 ASKL3 530.00 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right, Neutral Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 List Price $ 61.00 61.00 61.00 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB List Price $ 108.00 108.00 Shunt Trips Mounting Pocket List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 UVRLV600 List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 MOLDED CASE CIRCUIT BREAKERS Right Pocket Only Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 6 Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC 600 VAC Mounting Pocket Right Pocket Only ‘A’ refers to a normally open contact (open when the breaker contacts are open). ‘B’ refers to a normally closed contact (closed when the breaker contacts are open). 햲 Refer to the “Accessory Locations” chart for guidelines and limitations about which pockets may be used for accessory combinations. 햳 These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right. 햴 Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. Discount Schedule MCCB External Accessories pages 6-125 through 6-139 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-103 VL Circuit Breakers JG 400A Frame, VL Series Selection/Dimensions Ordering Information Complete Assembled Breaker Prices for a complete factory assembled JG breaker include the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to “X” for standard breakers. 100% Rated: For 100% rated breakers (or frames) with an interchangeable trip unit, change the 3rd character of the catalog name to ”H”. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to ”Y“. For 50˚C and special applications, refer to page 6-144.A Mounting hardware is included with each frame or complete breaker. Dimensions, inches (mm) Number of Poles 2, 3 4 Interrupting Ratings MOLDED CASE CIRCUIT BREAKERS 6 Breaker Type NJG HJG LJG RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 30 25 65 65 45 45 100 65 25 30 35 100 75 70 70 200 100 25 30 35 200 150 100 75 Length Depth To Handle D1 5.5 (139) 11 (279) 4.2 (102) 5.4 (138) 7.2 (183) Shipping Weight, lbs. (kg) Trip Unit 690 ICU 12 15 15 ICS 6 8 8 Poles Frame Thermal-Mag. Electronic 2, 3 9.3 (4.2) 4 12.1 (5.5) 4.0 (1.8) 5.0 (2.3) Complete Breaker 4.0 (1.8) 12.6 (5.7) 5.0 (2.3) 16.3 (7.4) EnclosuresA Connectors for 75°C Wire Ampere Construction Rating Steel 70-400 70-400 Aluminum햲 Aluminum 70-400 Aluminum 70-400 Copper 70-400 Copper 70-400 Distribution Lugs Wire Range 1/0–600 kcmil Cu 3/0–250 kcmil Al/Cu 250–750 kcmil Al 3/0–600 kcmil Cu 3/0–750 kcmil Cu 3/0–250 kcmil Cu No. of cables per connector 1 2 1 1 1 2 Catalog Number 3TW1JG600햳 3TA2JG250햳 3TA1JG750햳 3TA1JG750햳 TC1JG750햵 TC2JG250 List Price $ 87.00 87.00 109.00 109.00 77.00 77.00 70-400 70-400 Compression Lugs 70-400 70-400 70-400 #14–4 Cu #14–2/0 Cu 12 6 3TA12JG04햳 3TA6JG20햳 265.00 265.00 3CLJ600햴 3CLJ350 3CLJ750 449.00 449.00 449.00 250–600 kcmil Al/Cu #6–350 kcmil 250–750 kcmil Width – – – NEMA Class Catalog Number List Price $ 1 JG0401S CSO 1 (Compact) 3R 3R (Compact) 7-9 12 Neutral JG0401SC JG0403R JG0403RC JG03579 (350A max) JG04012 (future) CSO CSO CSO CSO CSO — 햲 Standard construction supplied for each breaker. Kit consists of 3 terminal connectors. 3 Lugs for 3-pole breakers. 햵 For 100% rate applications, 90°C. 햳 햴 JG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) Instantaneous Overcurrent Setting (Ii) Min. Max. 250 1250 2500 300 1500 3000 350 400 1750 2000 3500 4000 Note: Each breaker has 6 trip settings in this range. A - Consult with Siemens for availability. 6-104 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog External Accessories pages 6-125 through 6-139 Discount Schedule MCCB VL Circuit Breakers JG 400A Thermal-Magnetic Trip Unit Selection Ii M4-PAN-TORX M4-PAN-TORX AMPS 2800 2400 2000 I n = 400A 3200 40 C 3600 TM ~ 4000 Trip Unit/Disparador 525 Model 525 Trip Unit JG 400A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating 250 300 350 400 H-Interrupting Class Catalog Number List Price $ Catalog Number NJG2F400 1600.00 FRAME ONLY HJG2F400 3842.00 NJG2B250L NJG2B300L NJG2B350L NJG2B400L List Price $ COMPLETE FACTORY ASSEMBLED CIRCUIT 3210.00 HJG2B250L 5452.00 3210.00 HJG2B300L 5452.00 3210.00 HJG2B350L 5452.00 3210.00 HJG2B400L 5452.00 L-Interrupting Class Catalog Number List Price $ LJG2F400 5208.00 BREAKER LJG2B250L LJG2B300L LJG2B350L LJG2B400L 6818.00 6818.00 6818.00 6818.00 Catalog Number List Price $ TRIP UNIT ONLY CJT2B250 1494.00 CJT2B300 1494.00 CJT2B350 1494.00 CJT2B400 1494.00 JG 400A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating 250 300 350 400 H-Interrupting Class Catalog Number List Price $ Catalog Number NJG3F400 1972.00 FRAME ONLY HJG3F400 4484.00 NJG3B250L NJG3B300L NJG3B350L NJG3B400L List Price $ COMPLETE FACTORY ASSEMBLED CIRCUIT 3903.00 HJG3B250L 6415.00 3903.00 HJG3B300L 6415.00 3903.00 HJG3B350L 6415.00 3903.00 HJG3B400L 6415.00 L-Interrupting Class Catalog Number List Price $ LJG3F400 5740.00 BREAKER LJG3B250L LJG3B300L LJG3B350L LJG3B400L 7671.00 7671.00 7671.00 7671.00 Catalog Number List Price $ TRIP UNIT ONLY CJT3B250 1757.00 CJT3B300 1757.00 CJT3B350 1757.00 CJT3B400 1757.00 Continuous Ampere Rating 250 300 350 400 H-Interrupting Class List Price $ Catalog Number NJG4F400 2563.00 FRAME ONLY HJG4F400 5829.00 NJG4B250L NJG4B300L NJG4B350L NJG4B400L List Price $ COMPLETE FACTORY ASSEMBLED CIRCUIT 5080.00 HJG4B250L 8346.00 5080.00 HJG4B300L 8346.00 5080.00 HJG4B350L 8346.00 5080.00 HJG4B400L 8346.00 L-Interrupting Class Catalog Number List Price $ LJG4F400 7462.00 BREAKER LJG4B250L LJG4B300L LJG4B350L LJG4B400L 9979.00 9979.00 9979.00 9979.00 Catalog Number List Price $ TRIP UNIT ONLY CJT4B250 2285.00 CJT4B300 2285.00 CJT4B350 2285.00 CJT4B400 2285.00 JJ 400A Frame 240V max., 2-pole with Thermal-Magnetic Non-Interchangeable Trip Unit N-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number List Price $ COMPLETE BREAKER NJJ2B250L 2642.00 NJJ2B300L 2642.00 NJJ2B350L 2642.00 NJJ2B400L 2642.00 JJ 400A Frame 240V max., 3-pole with Thermal-Magnetic Non-Interchangeable Trip Unit N-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number List Price $ COMPLETE BREAKER NJJ3B250L 3192.00 NJJ3B300L 3192.00 NJJ3B350L 3192.00 NJJ3B400L 3192.00 A - Consult with Siemens for availability. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-105 MOLDED CASE CIRCUIT BREAKERS N-Interrupting Class Catalog Number 6 JG 400A Frame 4-Pole with Thermal-Magnetic Trip UnitA VL Circuit Breakers JG 400A Electronic 3-Knob & LCD Trip Units Selection Model 545 Trip Units JG 400A Frame 3-Pole Electronic Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NJG3F400 1972.00 FRAME ONLY HJG3F400 4484.00 L-Interrupting Class Catalog Number List Price $ LJG3F400 5740.00 Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NJG3N250L NJG3N400L 4468.00 4468.00 250 400 NJG3P250L NJG3P400L 4800.00 4800.00 250 400 NJG3U250L NJG3U400L 6682.00 6682.00 250 400 NJG3X250L NJG3X400L 6347.00 6347.00 TRIP UNIT ONLY LJG3N250L LJG3N400L 8236.00 8236.00 CJT3N250 CJT3N400 2322.00 2322.00 LJG3P250L LJG3P400L 8568.00 8568.00 CJT3P250 CJT3P400 2654.00 2654.00 LJG3U250L LJG3U400L 10450.00 10450.00 CJT3U250 CJT3U400 4536.00 4536.00 LJG3X250L LJG3X400L 10115.00 10115.00 CJT3X250 CJT3X400 4201.00 4201.00 Catalog Number List Price $ MOLDED CASE CIRCUIT BREAKERS 6 250 400 ELECTRONIC LI TRIP HJG3N250L 6980.00 HJG3N400L 6980.00 ELECTRONIC LSI TRIP HJG3P250L 7312.00 HJG3P400L 7312.00 ELECTRONIC LSIG TRIP HJG3U250L 9194.00 HJG3U400L 9194.00 ELECTRONIC LIG TRIP HJG3X250L 8859.00 HJG3X400L 8859.00 List Price $ Model 576 Trip Unit JG 400A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class Continuous Ampere Rating 6-106 H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NJG3F400 1972.00 FRAME ONLY HJG3F400 4484.00 L-Interrupting Class Catalog Number List Price $ LJG3F400 5740.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 250 400 NJG3D250L NJG3D400L 5198.00 5198.00 250 400 NJG3E250L NJG3E400L 7080.00 7080.00 LCD ELECTRONIC LSI TRIP HJG3D250L 7710.00 HJG3D400L 7710.00 LCD ELECTRONIC LSIG TRIP HJG3E250L 9592.00 HJG3E400L 9592.00 TRIP UNIT ONLY LJG3D250L LJG3D400L 8966.00 8966.00 CJT3D250 CJT3D400 3052.00 3052.00 LJG3E250L LJG3E400L 10848.00 10848.00 CJT3E250 CJT3E400 4934.00 4934.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB VL Circuit Breakers Internal Accessories for JG 400A and LG 600A Frames Selection Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/B햴 Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switches 1A + 1B, 1A/B햴 Bases AMBL2 & AMBL3 Mounting Pocket햲 Catalog Number List Price $ Left, Right햳 ASKL1 265.00 Left, Right, Neutral ASKL2 265.00 Left, Right햳 ASKL3 530.00 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right, Neutral Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 List Price $ 61.00 61.00 61.00 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB List Price $ 108.00 108.00 Shunt Trips Mounting Pocket Right Pocket Only List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 UVRLV600 List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 MOLDED CASE CIRCUIT BREAKERS Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 6 Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC 600 VAC Mounting Pocket Right Pocket Only ‘A’ refers to a normally open contact (open when the breaker contacts are open). ‘B’ refers to a normally closed contact (closed when the breaker contacts are open). 햲 Refer to the “Accessory Locations” chart for guidelines and limitations about which pockets may be used for accessory combinations. 햳 Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. Discount Schedule MCCB External Accessories pages 6-125 through 6-139 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-107 VL Circuit Breakers LG 600A Frame, VL Series Selection/Dimensions Ordering Information Complete Assembled Breaker Prices for a complete factory assembled LG breaker include the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. Change the third digit of the catalog number to “X” for non-interchangeable trip unit. For 50˚C and special applications, refer to page 6-144.A Mounting hardware is included with each frame or complete breaker. A Toggle Handle Extension is included with each frame or complete breaker. Dimensions, inches (mm) Interrupting Ratings Breaker Type NLG HLG LLG RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 30 25 65 65 45 45 100 65 25 30 35 100 75 70 70 200 100 25 30 35 200 150 100 75 Number of Poles 690 ICU 12 15 15 ICS 6 8 8 2, 3 4 Width Length Depth To Handle D1 5.5 (139) 11 (279) 4.2 (102) 5.4 (138) 7.2 (183) Ext. Shield 13.6 (345.5) Shipping Weight, lbs. (kg) MOLDED CASE CIRCUIT BREAKERS 6 Connectors for 75°C Wire Ampere Construction Rating Aluminum햲 150-600 150-600 Aluminum햲 Copper 150-600 Copper 150-600 Compression Lugs 150-600 150-600 150-600 Trip Unit Poles Frame Wire Range #2/0–600 kcmil Al/Cu #2/0–600 kcmil Al/Cu #2/0–600 kcmil Cu #2/0–600 kcmil Cu No. of cables per connector 2 (load side) 2 (line side) 2 (load side) 2 (line side) Catalog Number햳 3TA2LG600LD 3TA2LG600LN 3TC2LG600LD 3TC2LG600LN List Price $ 109.00 109.00 231.00 231.00 #6–350 kcmil Al/Cu 250-750 kcmil Al/Cu 250-600 kcmil Al/Cu – – – 6CLL350햴 3CLL750햵 6CLL600햴 899.00 494.00 899.00 햲 Standard construction supplied for each breaker. Kit consists of 3 terminal connectors. 햴 Kit consists of 6 lugs for Line or Load end. 햵 Kit consists of 3 lugs for Line or Load end. 햳 2, 3 17.4 (7.9) 4 23.2 (10.5) Thermal-Mag. 3.5 (1.6) 4.6 (2.1) Electronic Complete Breaker 4.2 (1.9) 20.9 (9.5) 5.5 (2.5) 27.8 (12.6) EnclosuresA NEMA Class Catalog Number List Price $ 1 3R 4 – 4X 7-9 12 Neutral LG0601S LG0603R LG0604S LG06079 LG06012 (future) CSO CSO CSO CSO CSO — LG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 400 500 600 Instantaneous Overcurrent Setting (Ii) Min. Max. 2000 2500 2750 4000 5000 5500 Note: Each breaker has 6 trip settings. A - Consult with Siemens for availability. 6-108 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog External Accessories pages 6-125 through 6-139 Discount Schedule MCCB VL Circuit Breakers LG 600A Thermal-Magnetic Trip Unit Selection Type/Tipo CLT3 Ii M4-PAN-TORX M4-PAN-TORX I n = 600A 3850 3300 4400 40 C 4950 2750 TM ~ 5500 Trip Unit/Disparador 525 Cat. No. CLT3B600 Model 525 Trip Unit LG 600A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating 400 500 600 H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NLG2F600 2869.00 FRAME ONLY HLG2F600 4023.00 L-Interrupting Class Catalog Number LLG2F600 List Price $ 5148.00 5148.00 5148.00 HLG2B400L HLG2B500L HLG2B600L 6302.00 6302.00 6302.00 LLG2B400L LLG2B500L LLG2B600L List Price $ 6809.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NLG2B400L NLG2B500L NLG2B600L Catalog Number TRIP UNIT ONLY 9088.00 9088.00 9088.00 CLT2B400 CLT2B500 CLT2B600 2135.00 2135.00 2135.00 Catalog Number List Price $ LG 600A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating List Price $ Catalog Number List Price $ NLG3F600 3548.00 FRAME ONLY HLG3F600 4684.00 L-Interrupting Class Catalog Number LLG3F600 List Price $ 7508.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NLG3B400L NLG3B500L NLG3B600L 6276.00 6276.00 6276.00 HLG3B400L HLG3B500L HLG3B600L 7412.00 7412.00 7412.00 LLG3B400L LLG3B500L LLG3B600L TRIP UNIT ONLY 10236.00 10236.00 10236.00 CLT3B400 CLT3B500 CLT3B600 2512.00 2512.00 2512.00 6 400 500 600 H-Interrupting Class Catalog Number MOLDED CASE CIRCUIT BREAKERS Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-109 VL Circuit Breakers LG 600A Electronic 3-Knob & LCD Trip Units Selection Model 545 Trip Unit LG 600A Frame 3-Pole Electronic Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NLG3F600 3548.00 FRAME ONLY HLG3F600 4684.00 L-Interrupting Class Catalog Number List Price $ LLG3F600 7508.00 Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NLG3N400L NLG3N600L 6865.00 6865.00 400 600 NLG3P400L NLG3P600L 7200.00 7200.00 400 600 NLG3U400L NLG3U600L 9128.00 9128.00 400 600 NLG3X400L NLG3X600L 8794.00 8794.00 TRIP UNIT ONLY LLG3N400L LLG3N600L 10825.00 10825.00 CLT3N400 CLT3N600 3101.00 3101.00 LLG3P400L LLG3P600L 11160.00 11160.00 CLT3P400 CLT3P600 3436.00 3436.00 LLG3U400L LLG3U600L 13088.00 13088.00 CLT3U400 CLT3U600 5364.00 5364.00 LLG3X400L LLG3X600L 12754.00 12754.00 CLT3X400 CLT3X600 5030.00 5030.00 Catalog Number List Price $ MOLDED CASE CIRCUIT BREAKERS 6 400 600 ELECTRONIC LI TRIP HLG3N400L 8001.00 HLG3N600L 8001.00 ELECTRONIC LSI TRIP HLG3P400L 8336.00 HLG3P600L 8336.00 ELECTRONIC LSIG TRIP HLG3U400L 10264.00 HLG3U600L 10264.00 ELECTRONIC LIG TRIP HLG3X400L 9930.00 HLG3X600L 9930.00 List Price $ Model 576 Trip Unit LG 600A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class Continuous Ampere Rating 6-110 H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NLG3F600 3548.00 FRAME ONLY HLG3F600 4684.00 L-Interrupting Class Catalog Number List Price $ LLG3F600 7508.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 400 600 NLG3D400L NLG3D600L 7714.00 7714.00 400 600 NLG3E400L NLG3E600L 9643.00 9643.00 LCD ELECTRONIC LSI TRIP HLG3D400L 8850.00 HLG3D600L 8850.00 LCD ELECTRONIC LSIG TRIP HLG3E400L 10779.00 HLG3E600L 10779.00 TRIP UNIT ONLY LLG3D400L LLG3D600L 11674.00 11674.00 CLT3D400 CLT3D600 3950.00 3950.00 LLG3E400L LLG3E600L 13603.00 13603.00 CLT3E400 CLT3E600 5879.00 5879.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB VL Circuit Breakers Internal Accessories for JG 400A and LG 600A Frames Selection Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/B햴 Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switches 1A + 1B, 1A/B햴 Bases AMBL2 & AMBL3 Mounting Pocket햲 Catalog Number List Price $ Left, Right햳 ASKL1 265.00 Left, Right, Neutral ASKL2 265.00 Left, Right햳 ASKL3 530.00 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right, Neutral Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 List Price $ 61.00 61.00 61.00 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB List Price $ 108.00 108.00 Shunt Trips Mounting Pocket Right Pocket Only List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 UVRLV600 List Price $ 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 594.00 MOLDED CASE CIRCUIT BREAKERS Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 6 Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC 600 VAC Mounting Pocket Right Pocket Only ‘A’ refers to a normally open contact (open when the breaker contacts are open). ‘B’ refers to a normally closed contact (closed when the breaker contacts are open). 햲 Refer to the “Accessory Locations” chart for guidelines and limitations about which pockets may be used for accessory combinations. 햳 Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. Discount Schedule MCCB External Accessories pages 6-125 through 6-139 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-111 VL Circuit Breakers MG 800A Frame, VL Series Selection/Dimensions Ordering Information Complete Assembled Breaker Prices for a complete factory assembled MG breaker include the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to “X” for standard breakers. 100% Rated: For 100% rated breakers (or frames) with an interchangeable trip unit, change the 3rd character of the catalog name to ”H”. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to ”Y“. For 50˚C and special applications, refer to page 6-144.A Mounting hardware is included with each frame or complete breaker. A Toggle Handle Extension is included with each frame or complete breaker. MOLDED CASE CIRCUIT BREAKERS 6 Interrupting Ratings Breaker Type NMG HMG LMG RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 22 35 65 65 50 50 100 65 35 25 50 100 75 70 70 200 100 50 42 65 200 150 100 75 Number of Poles 2, 3 4 Width Length Depth To Handle D1 7.5 (190) 16 (406) 4.5 (114) 5.9 (151) 10 (253) Shipping Weight, lbs. (kg) 690 ICU 20 30 35 ICS 10 15 17 Connectors for 75°C Wire Ampere Construction Rating Aluminum햴 200-800A Aluminum 200-800A Copper 200-800A Aluminum 200-800A Compression Lug Kit햲 200-800A Dimensions, inches (mm) Wire Range 1/0–500 kcmil Al/Cu 500-750 kcmil Al/Cu 1/0–500 kcmil Cu #2–600 kcmil Al/Cu No. of cables per connector 3 2 3 3 Catalog Number 3TA3MG500햳 3TA2MG750햳 TC3MG500햶햷 3TA3MG600햳햵 List Price $ 202.00 364.00 134.00 218.00 1/0–500 kcmil Cu – 9CLM500햲 1056.00 Poles Frame 2, 3 4 31.3 (14.2) 40.2 (18.2) Trip Unit Complete Breaker 4.0 (1.8) 5.0 (2.3) 35.3 (16.0) 45.2 (20.5) EnclosuresA NEMA Class Catalog Number List Price $ 1 3R Neutral MG0801S MG0803R (future) CSO CSO — 햲 Total of 9 connectors (3 per phase Line or Load). 햳 Kit consists of 3 terminal connectors. 햴 Standard connector supplied with complete breakers. 햵 Includes extended terminal cover. 햶 Consists of one terminal. 햷 For 100% rated applications. MG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 600 700 800 Instantaneous Overcurrent Setting (Ii) Min. Max. 3000 3250 3250 6000 6500 6500 Note: Each breaker has 6 trip settings. A - Consult with Siemens for availability. 6-112 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog External Accessories pages 6-125 through 6-139 Discount Schedule MCCB VL Circuit Breakers MG 800A Thermal-Magnetic Trip Unit Selection AMPS Ii I n = 800A 4550 5200 3900 5850 3250 6500 40 C TM ~ Trip Unit/Disparador 525 Model 525 Trip Unit MG 800A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating 600 700 800 Catalog Number List Price $ NMG2F800 3502.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HMG2F800 5208.00 L-Interrupting Class Catalog Number LMG2F800 List Price $ 6456.00 6456.00 6456.00 HMG2B600L HMG2B700L HMG2B800L 8162.00 8162.00 8162.00 LMG2B600L LMG2B700L LMG2B800L List Price $ 8238.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NMG2B600L NMG2B700L NMG2B800L Catalog Number TRIP UNIT ONLY 11192.00 11192.00 11192.00 CMT2B600 CMT2B700 CMT2B800 2686.00 2686.00 2686.00 Catalog Number List Price $ MG 800A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating List Price $ NMG3F800 4305.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HMG3F800 6033.00 L-Interrupting Class Catalog Number LMG3F800 List Price $ 9039.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NMG3B600L NMG3B700L NMG3B800L 7868.00 7868.00 7868.00 HMG3B600L HMG3B700L HMG3B800L 9596.00 9596.00 9596.00 LMG3B600L LMG3B700L LMG3B800L TRIP UNIT ONLY 12602.00 12602.00 12602.00 CMT3B600 CMT3B700 CMT3B800 3161.00 3161.00 3161.00 6 600 700 800 Catalog Number MOLDED CASE CIRCUIT BREAKERS Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-113 VL Circuit Breakers MG 800A Electronic 3-Knob & LCD Trip Units Selection Alarm >1.05 Ir 400 680HG Amps t sd 2 2.5 4 7 xI r 630 .2 Sec. 6 5 2 I t ON 2 .3 .1 I t V1.04 .4 OFF .5 0 3 1.5 600 700 1.5 sd 1.5 500 800 X3 I 315 350 300 300 .4 .1 .3 .2 Active Model 545 Trip Units MG 800A Frame 3-Pole Electronic Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NMG3F800 4305.00 FRAME ONLY HMG3F800 6033.00 L-Interrupting Class Catalog Number List Price $ LMG3F800 9039.00 Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 600 800 NMG3N600L NMG3N800L 8672.00 8672.00 600 800 NMG3P600L NMG3P800L 9006.00 9006.00 600 800 NMG3U600L NMG3U800L 10935.00 10935.00 600 800 NMG3X600L NMG3X800L 10602.00 10602.00 ELECTRONIC LI TRIP HMG3N600L 10400.00 HMG3N800L 10400.00 ELECTRONIC LSI TRIP HMG3P600L 10734.00 HMG3P800L 10734.00 ELECTRONIC LSIG TRIP HMG3U600L 12663.00 HMG3U800L 12663.00 ELECTRONIC LIG TRIP HMG3X600L 12330.00 HMG3X800L 12330.00 List Price $ TRIP UNIT ONLY LMG3N600L LMG3N800L 13406.00 13406.00 CMT3N600 CMT3N800 3965.00 3965.00 LMG3P600L LMG3P800L 13740.00 13740.00 CMT3P600 CMT3P800 4299.00 4299.00 LMG3U600L LMG3U800L 15669.00 15669.00 CMT3U600 CMT3U800 6228.00 6228.00 LMG3X600L LMG3X800L 15336.00 15336.00 CMT3X600 CMT3X800 5895.00 5895.00 Catalog Number List Price $ MG 800A Frame 4-Pole Electronic Trip UnitA Continuous Ampere Rating MOLDED CASE CIRCUIT BREAKERS 6 N-Interrupting Class H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NMG4F800 5597.00 FRAME ONLY HMG4F800 7844.00 L-Interrupting Class Catalog Number List Price $ LMG4F800 11753.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 600 800 NMG4N600L NMG4N800L 11289.00 11289.00 600 800 NMG4P600L NMG4P800L 11722.00 11722.00 600 800 NMG4U600L NMG4U800L 14230.00 14230.00 600 800 NMG4X600L NMG4X800L 13796.00 13796.00 ELECTRONIC LI TRIP HMG4N600L 13536.00 HMG4N800L 13536.00 ELECTRONIC LSI TRIP HMG4P600L 13969.00 HMG4P800L 13969.00 ELECTRONIC LSIG TRIP HMG4U600L 16477.00 HMG4U800L 16477.00 ELECTRONIC LIG TRIP HMG4X600L 16043.00 HMG4X800L 16043.00 TRIP UNIT ONLY LMG4N600L LMG4N800L 17445.00 17445.00 CMT4N600 CMT4N800 5156.00 5156.00 LMG4P600L LMG4P800L 17878.00 17878.00 CMT4P600 CMT4P800 5589.00 5589.00 LMG4U600L LMG4U800L 20386.00 20386.00 CMT4U600 CMT4U800 8097.00 8097.00 LMG4X600L LMG4X800L 19952.00 19952.00 CMT4X600 CMT4X800 7663.00 7663.00 A= 605 B= 612 C= 615 N= 0 X3 680JM Model 576 Trip Unit MG 800A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NMG3F800 4305.00 FRAME ONLY HMG3F800 6033.00 L-Interrupting Class Catalog Number List Price $ LMG3F800 9039.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 600 800 NMG3D600L NMG3D800L 9650.00 9650.00 600 800 NMG3E600L NMG3E800L 11581.00 11581.00 LCD ELECTRONIC LSI TRIP HMG3D600L 11378.00 HMG3D800L 11378.00 LCD ELECTRONIC LSIG TRIP HMG3E600L 13309.00 HMG3E800L 13309.00 Catalog Number List Price $ TRIP UNIT ONLY LMG3D600L LMG3D800L 14384.00 14384.00 CMT3D600 CMT3D800 4943.00 4943.00 LMG3E600L LMG3E800L 16315.00 16315.00 CMT3E600 CMT3E800 6874.00 6874.00 A - Consult with Siemens for availability. 6-114 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB VL Circuit Breakers Internal Accessories for MG 800A, NG 1200A and PG 1600A Frames Selection Auxiliary Switch and Alarm Switch Combination Kits Description 2 Aux. + 2 Alarm Switches 2A + 2B Bases AMBP2 4 Aux. Switches 2A + 2B Bases AMBP1 Mounting Pocket햲 Catalog Number List Price $ Left Pocket Only ASKP3 530.00 Left, Right, Neutral ASKP4 495.00 x4 Auxiliary/Alarm Switch Mounting Base Only Description Up to 4 Auxiliary Switches 2 Aux. + 2 Alarm Switches Mounting Pocket Left, Right, Neutral Left Pocket Only Catalog Number AMBP1 AMBP2 List Price $ 83.00 83.00 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB List Price $ 108.00 108.00 x4 Shunt Trips Mounting Pocket Right Pocket Only List Price $ 654.00 654.00 654.00 654.00 654.00 654.00 654.00 654.00 Catalog Number UVRPA12DC UVRPB24DC UVRPC48DC UVRPG60DC UVRPD125DC UVRPE250DC UVRPN120 UVRPR240 UVRPP208 UVRPS277 UVRPT415 UVRPU480 UVRPV600 List Price $ 654.00 654.00 654.00 654.00 654.00 654.00 654.00 654.00 654.00 654.00 654.00 654.00 654.00 MOLDED CASE CIRCUIT BREAKERS Catalog Number STRPB24DC STRPC60DC STRPD125DC STRPE250DC STRPM60 STRPN120 STRPS277 STRPV600 6 Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC 600 VAC Mounting Pocket Right Pocket Only ‘A’ refers to a normally open contact (open when the breaker contacts are open). ‘B’ refers to a normally closed contact (closed when the breaker contacts are open). 햲 Refer to the “Accessory Locations” chart for guidelines and limitations about which pockets may be used for accessory combinations. External Accessories pages 6-125 through 6-139 Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-115 VL Circuit Breakers NG 1200A Frame, VL Series Selection/Dimensions Ordering Information Complete Assembled Breaker with Lugs Prices for a complete factory assembled NG breaker include the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to “X” for standard breakers. 100% Rated: For 100% rated breakers (or frames) with an interchangeable trip unit, change the 3rd character of the catalog name to ”H”. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to ”Y“. For 50˚C and special applications, refer to page 6-144.A Mounting hardware is included with each frame or complete breaker. A Toggle Handle Extension is included with each frame or complete breaker. 6 MOLDED CASE CIRCUIT BREAKERS RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 22 35 65 35 50 25 100 65 35 25 50 100 50 70 35 200 100 65 42 65 200 100 100 50 W L D To Handle D1 9 (229) 12 (305) 16 (406) 6 (152) 8.1 (207) Shipping Weight, lbs. (kg) 690 ICU 20 30 35 ICS 10 15 17 Connectors for 75°C Wire Ampere Construction Rating Aluminum 300-1200A Aluminum 300-1200A Copper 300-1200A Aluminum 300-1200A Compression Lug Kit햲 300-1200A Number of Poles 2, 3 4 Interrupting Ratings Breaker Type NNG HNG LNG Dimensions, inches (mm) Wire Range 1/0–500 kcmil Al/Cu 500-750 kcmil Al/Cu 1/0–500 kcmil Cu햳 1/0–500 kcmil Al/Cu No. of cables per connector 4 3 4 4 Catalog Number 3TA4NG500햴햵 3TA3NG750햵 3TC4NG500햵 3TA4NG500H햵 List Price $ 291.00 832.00 832.00 875.00 1/0–500 kcmil Al/Cu – 12CLN500 1393.00 Poles Frame 2, 3 4 46.3 (21.0) 60.6 (27.5) Trip Unit Complete Breaker 8.8 (4.0) 13.2 (6.0) 55.1 (25.0) 73.8 (33.5) EnclosuresA Type Catalog Number List Price $ 1 NG1201S CSO 3R NG1203R CSO 12 NG12012 CSO Neutral (future) — 햲 Total of 12 connectors (4 per phase Line or Load). 햳 90 °C for 100% rated breakers. 햴 Standard connector provided with complete breakers. 햵 Kit consists of 3 terminal connectors. NG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 800 900 1000 1200 Instantaneous Overcurrent Setting (Ii) Min. Max. 4000 5000 5000 7000 8000 10000 10000 12000 Note: Each breaker has 6 trip settings. A - Consult with Siemens for availability. 6-116 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog External Accessories pages 6-125 through 6-139 Discount Schedule MCCB VL Circuit Breakers NG 1200A Thermal-Magnetic Trip Unit Selection I n = 1200A Ii AMPS 9000 8000 9000 TM ~ 11000 7000 Ii 12000 Ii AMPS 40 C 10000 11000 7000 Trip Unit/Disparador 525 AMPS 9000 10000 8000 12000 10000 8000 11000 7000 12000 Amps Amps Model 525 Trip Unit NG 1200A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating 800 900 1000 1200 H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NNG2F120 5135.00 FRAME ONLY HNG2F120 6853.00 L-Interrupting Class Catalog Number LNG2F120 List Price $ 10945.00 10945.00 10945.00 10945.00 HNG2B800L HNG2B900L HNG2B100L HNG2B120L 12663.00 12663.00 12663.00 12663.00 LNG2B800L LNG2B900L LNG2B100L LNG2B120L List Price $ 10000.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NNG2B800L NNG2B900L NNG2B100L NNG2B120L Catalog Number TRIP UNIT ONLY 15810.00 15810.00 15810.00 15810.00 CNT2B800 CNT2B900 CNT2B100 CNT2B120 5418.00 5418.00 5418.00 5418.00 Catalog Number List Price $ NG 1200A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating List Price $ Catalog Number List Price $ NNG3F120 6321.00 FRAME ONLY HNG3F120 7937.00 L-Interrupting Class Catalog Number LNG3F120 List Price $ 10960.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER Discount Schedule MCCB 13284.00 13284.00 13284.00 13284.00 HNG3B800L HNG3B900L HNG3B100L HNG3B120L 14900.00 14900.00 14900.00 14900.00 LNG3B800L LNG3B900L LNG3B100L LNG3B120L TRIP UNIT ONLY 17923.00 17923.00 17923.00 17923.00 CNT3B800 CNT3B900 CNT3B100 CNT3B120 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6375.00 6375.00 6375.00 6375.00 6-117 MOLDED CASE CIRCUIT BREAKERS NNG3B800L NNG3B900L NNG3B100L NNG3B120L 6 800 900 1000 1200 H-Interrupting Class Catalog Number VL Circuit Breakers NG 1200A Electronic 3-Knob & LCD Trip Units Selection In = 1200 A ~ Alarm >1.05 Ir 630 700 800 1200 Amps tr 500 600 400 400 X3 Trip Unit/Disparador 1000 900 6 8 25 20 4 240 360 480 180 14 600 150 1200 17 30 V2.02 Ii 10 2.5 Sec. Amps x10 720 1200 960 Active 545 2 4 6 Model 545 Trip Units Model 576 Trip Unit NG 1200A Frame 3-Pole Electronic Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NNG3F120 6321.00 FRAME ONLY HNG3F120 7937.00 L-Interrupting Class Catalog Number LNG3F120 List Price $ 800 1000 1200 NNG3N800L NNG3N100L NNG3N120L 14651.00 14651.00 14651.00 800 1000 1200 NNG3P800L NNG3P100L NNG3P120L 14985.00 14985.00 14985.00 800 1000 1200 NNG3U800L NNG3U100L NNG3U120L 16914.00 16914.00 16914.00 800 1000 1200 NNG3X800L NNG3X100L NNG3X120L 16581.00 16581.00 16581.00 List Price $ 10960.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER ELECTRONIC LI TRIP HNG3N800L 16267.00 HNG3N100L 16267.00 HNG3N120L 16267.00 ELECTRONIC LSI TRIP HNG3P800L 16601.00 HNG3P100L 16601.00 HNG3P120L 16601.00 ELECTRONIC LSIG TRIP HNG3U800L 18530.00 HNG3U100L 18530.00 HNG3U120L 18530.00 ELECTRONIC LIG TRIP HNG3X800L 18197.00 HNG3X100L 18197.00 HNG3X120L 18197.00 Catalog Number TRIP UNIT ONLY LNG3N800L LNG3N100L LNG3N120L 19290.00 19290.00 19290.00 CNT3N800 CNT3N100 CNT3N120 7742.00 7742.00 7742.00 LNG3P800L LNG3P100L LNG3P120L 19624.00 19624.00 19624.00 CNT3P800 CNT3P100 CNT3P120 8076.00 8076.00 8076.00 LNG3U800L LNG3U100L LNG3U120L 21553.00 21553.00 21553.00 CNT3U800 CNT3U100 CNT3U120 10005.00 10005.00 10005.00 LNG3X800L LNG3X100L LNG3X120L 21220.00 21220.00 21220.00 CNT3X800 CNT3X100 CNT3X120 9672.00 9672.00 9672.00 Catalog Number List Price $ NG 1200A Frame 4-Pole Electronic Trip UnitA MOLDED CASE CIRCUIT BREAKERS 6 N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NNG4F120 8218.00 FRAME ONLY HNG4F120 10319.00 L-Interrupting Class Catalog Number LNG4F120 List Price $ 14249.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 800 1000 1200 NNG4N800L NNG4N100L NNG4N120L 19066.00 19066.00 19066.00 800 1000 1200 NNG4P800L NNG4P100L NNG4P120L 19501.00 19501.00 19501.00 800 1000 1200 NNG4U800L NNG4U100L NNG4U120L 22009.00 22009.00 22009.00 800 1000 1200 NNG4X800L NNG4X100L NNG4X120L 21576.00 21576.00 21576.00 ELECTRONIC LI TRIP HNG4N800L 21167.00 HNG4N100L 21167.00 HNG4N120L 21167.00 ELECTRONIC LSI TRIP HNG4P800L 21602.00 HNG4P100L 21602.00 HNG4P120L 21602.00 ELECTRONIC LSIG TRIP HNG4U800L 24110.00 HNG4U100L 24110.00 HNG4U120L 24110.00 ELECTRONIC LIG TRIP HNG4X800L 23677.00 HNG4X100L 23677.00 HNG4X120L 23677.00 TRIP UNIT ONLY LNG4N800L LNG4N100L LNG4N120L 25097.00 25097.00 25097.00 CNT4N800 CNT4N100 CNT4N120 10064.00 10064.00 10064.00 LNG4P800L LNG4P100L LNG4P120L 25532.00 25532.00 25532.00 CNT4P800 CNT4P100 CNT4P120 10499.00 10499.00 10499.00 LNG4U800L LNG4U100L LNG4U120L 28040.00 28040.00 28040.00 CNT4U800 CNT4U100 CNT4U120 13007.00 13007.00 13007.00 LNG4X800L LNG4X100L LNG4X120L 27607.00 27607.00 27607.00 CNT4X800 CNT4X100 CNT4X120 12574.00 12574.00 12574.00 NG 1200A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NNG3F120 6321.00 FRAME ONLY HNG3F120 7937.00 L-Interrupting Class Catalog Number LNG3F120 List Price $ 800 1000 1200 NNG3D800L NNG3D100L NNG3D120L 16196.00 16196.00 16196.00 800 1000 1200 NNG3E800L NNG3E100L NNG3E120L 18125.00 18125.00 18125.00 List Price $ 10960.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER LCD ELECTRONIC LSI TRIP HNG3D800L 17812.00 HNG3D100L 17812.00 HNG3D120L 17812.00 LCD ELECTRONIC LSIG 4-W TRIP HNG3E800L 19741.00 HNG3E100L 19741.00 HNG3E120L 19741.00 Catalog Number TRIP UNIT ONLY LNG3D800L LNG3D100L LNG3D120L 20835.00 20835.00 20835.00 CNT3D800 CNT3D100 CNT3D120 9287.00 9287.00 9287.00 LNG3E800L LNG3E100L LNG3E120L 22764.00 22764.00 22764.00 CNT3E800 CNT3E100 CNT3E120 11216.00 11216.00 11216.00 A - Consult with Siemens for availability. 6-118 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB VL Circuit Breakers Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames Selection Auxiliary Switch and Alarm Switch Combination Kits Description Mounting Pocket햲 Catalog Number List Price $ Left Pocket Only ASKP3 530.00 Left, Right, Neutral ASKP4 495.00 2 Aux. + 2 Alarm Switches 2A + 2B Base AMBP2 4 Aux. Switches 2A + 2B Base AMBP1 x4 Auxiliary/Alarm Switch Mounting Base Only Description Mounting Pocket햲 Catalog Number List Price $ Up to 4 Auxiliary Switches 2 Aux. + 2 Alarm Switches Left, Right, Neutral Left Pocket Only AMBP1 AMBP2 83.00 83.00 Auxiliary/Alarm Switch Only Common to DG-PG Frames Description Catalog Number List Price $ 1 Normally Open Contact (1A) ASWPA 108.00 1 Normally Closed Contact (1B) ASWPB 108.00 x4 Shunt Trips Description Mounting Pocket 654.00 48-60 VDC STRPC60DC 654.00 STRPD125DC 654.00 STRPE250DC 654.00 48-60 VAC STRPM60 654.00 110-127 VAC STRPN120 654.00 208-277 VAC STRPS277 654.00 380-600 VAC STRPV600 654.00 Catalog Number List Price $ 110-127 VDC 220-250 VDC Right Pocket Only MOLDED CASE CIRCUIT BREAKERS List Price $ STRPB24DC 6 Catalog Number 24 VDC Undervoltage Release Description Mounting Pocket 12 VDC UVRPA12DC 654.00 24 VDC UVRPB24DC 654.00 48 VDC UVRPC48DC 654.00 60 VDC UVRPG60DC 654.00 110-127 VDC UVRPD125DC 654.00 UVRPE250DC 654.00 220-250 VDC 110-127 VAC Right Pocket Only 220-240 VAC UVRPN120 654.00 UVRPR240 654.00 208 VAC UVRPP208 654.00 277 VAC UVRPS277 654.00 380-415 VAC UVRPT415 654.00 440-480 VAC UVRPU480 654.00 600 VAC UVRPV600 654.00 ‘A’ refers to a normally open contact (open when the breaker contacts are open). ‘B’ refers to a normally closed contact (closed when the breaker contacts are open). 햲 Refer to the “Accessory Locations” chart for guidelines and limitations about which pockets may be used for accessory combinations. External Accessories pages 6-125 through 6-139 Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-119 VL Circuit Breakers PG 1600A Frame, VL Series & Thermal-Magnetic Trip Unit Selection/Dimensions Ordering Information Prices for a complete factory assembled PG breaker include the frame and trip unit only. The connectors must be ordered as separate items. For any other configuration, order the frame, trip unit, and connectors as separate items. Connectors require a Breaker Lug Mounting Assembly or Breaker Mounting Base and must be ordered as a seperate item. For DC applications, use Thermal magnetic trip unit only. For reverse feed applications select non-interchangeable trip breakers only. Change the third digit of the catalog number to “X” for non-interchangeable trip breakers. 100% Rated: For 100% rated breakers (or frames) with an interchangeable trip unit, change the 3rd character of the catalog name to ”H”. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to ”Y“. For 50˚C and special applications, refer to page 6-144.A Mounting hardware is included with each frame or complete breaker. A Toggle Handle Extension is included with each frame or complete breaker. 6 MOLDED CASE CIRCUIT BREAKERS RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 240 480 600 250 500 ICU ICS ICU ICS 65 35 25 22 35 65 35 50 25 100 65 35 25 50 100 50 70 35 200 100 65 42 65 200 100 100 50 Ampere Rating 1200-1600A 1200-1600A 1200-1600A 1200-1600A 1200-1600A 1200-1600A Wire Range 1/0–750 kcmil Al/Cu 1/0–750 kcmil Cu 300–600 kcmil 600–750 kcmil 300–600 kcmil 300–600 kcmil No. of cables per phase 6 6 5 4 6 5 W L D To Handle D1 9 (229) 12 (305) 16 (406) 6 (152) 8.1 (207) Shipping Weight, lbs. (kg) 690 ICU 20 30 35 ICS 10 15 17 Connectors for 75°C Wire Construction Aluminum Copper Aluminum Aluminum Aluminum Copper Number of Poles 2, 3 4 Interrupting Ratings Breaker Type NPG HPG LPG Dimensions, inches (mm) Catalog List Number Price $ 3TA6PG750햲햴햷 940.00 3TC6PG750 (future)햲햴 1342.00 320.00 TA5P600햳햵 254.00 TA4P750햳햵 338.00 TA6R600햳햵 426.00 TC5R600햳햵햶 햲 Requires Lug Mounting Assembly LMAP1600. Requires Breaker Mounting Base MBPG1600 Kit or MBPG1601. Consists of 3 connectors. 햵 Consists of 1 connector. 햶 For 100% rated applications, 90°C. 햷 Standard connector provided with complete breaker. Poles Frame Trip Unit Complete Breaker 2, 3 4 60.2 (27.3) 76.7 (34.8) 8.8 (4.0) 13.2 (6.0) 69.0 (31.3) 89.9 (40.8) PG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 1200 1400 1600 Instantaneous Overcurrent Setting (Ii) Min. Max. 7000 7000 7000 12000 12000 12000 Note: Each breaker has 6 trip settings in this range. 햳 햴 Mounting Arrangement Description Lug Mounting Assembly Breaker Mounting Base (Front Connect) Breaker Mounting Base (Rear Connect) Catalog Number LMAP1600 MBPG1600 MBPG1601 List Price $ 968.00 1153.00 1153.00 Model 525 Trip Unit PG 1600A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class Continuous Ampere Rating 1200 1400 1600 Catalog Number List Price $ NPG3F160 8983.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HPG3F160 9944.00 L-Interrupting Class Catalog Number LPG3F160 NPG3B120 NPG3B140 NPG3B160 17276.00 17276.00 17276.00 HPG3B120 HPG3B140 HPG3B160 18237.00 18237.00 18237.00 LPG3B120 LPG3B140 LPG3B160 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog Number List Price $ 12158.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER A - Consult with Siemens for availability. 6-120 List Price $ TRIP UNIT ONLY 20451.00 20451.00 20451.00 CPT3B120 CPT3B140 CPT3B160 8293.00 8293.00 8293.00 External Accessories pages 6-125 through 6-139 Discount Schedule MCCB VL Circuit Breakers PG 1600A Electronic 3-Knob & LCD Trip Units Selection Model 545 Trip Unit PG 1600A Frame 3-Pole Electronic Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NPG3F160 8983.00 FRAME ONLY HPG3F160 9944.00 L-Interrupting Class Catalog Number LPG3F160 List Price $ Catalog Number 12158.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER 1200 1600 NPG3N120 NPG3N160 18743.00 18743.00 1200 1600 NPG3P120 NPG3P160 19077.00 19077.00 1200 1600 NPG3U120 NPG3U160 21006.00 21006.00 1200 1600 NPG3X120 NPG3X160 20672.00 20672.00 ELECTRONIC LI TRIP HPG3N120 19704.00 HPG3N160 19704.00 ELECTRONIC LSI TRIP HPG3P120 20038.00 HPG3P160 20038.00 ELECTRONIC LSIG TRIP HPG3U120 21967.00 HPG3U160 21967.00 ELECTRONIC LIG TRIP HPG3X120 21633.00 HPG3X160 21633.00 List Price $ TRIP UNIT ONLY LPG3N120 LPG3N160 21918.00 21918.00 CPT3N120 CPT3N160 9760.00 9760.00 LPG3P120 LPG3P160 22252.00 22252.00 CPT3P120 CPT3P160 10094.00 10094.00 LPG3U120 LPG3U160 24181.00 24181.00 CPT3U120 CPT3U160 12023.00 12023.00 LPG3X120 LPG3X160 23847.00 23847.00 CPT3X120 CPT3X160 11689.00 11689.00 PG 1600A Frame 4-Pole Electronic Trip UnitA N-Interrupting Class Catalog Number NPG4F160 11678.00 H-Interrupting Class Catalog Number List Price $ FRAME ONLY HPG4F160 12927.00 L-Interrupting Class Catalog Number LPG4F160 List Price $ Catalog Number 15806.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NPG4N120 NPG4N160 24367.00 24367.00 1200 1600 NPG4P120 NPG4P160 24800.00 24800.00 1200 1600 NPG4U120 NPG4U160 27308.00 27308.00 1200 1600 NPG4X120 NPG4X160 26874.00 26874.00 TRIP UNIT ONLY LPG4N120 LPG4N160 28495.00 28495.00 CPT4N120 CPT4N160 12689.00 12689.00 LPG4P120 LPG4P160 28928.00 28928.00 CPT4P120 CPT4P160 13122.00 13122.00 LPG4U120 LPG4U160 31436.00 31436.00 CPT4U120 CPT4U160 15630.00 15630.00 LPG4X120 LPG4X160 31002.00 31002.00 CPT4X120 CPT4X160 15196.00 15196.00 Model 576 Trip Unit PG 1600A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class Continuous Ampere Rating H-Interrupting Class Catalog Number List Price $ Catalog Number List Price $ NPG3F160 8983.00 FRAME ONLY HPG3F160 9944.00 L-Interrupting Class Catalog Number LPG3F160 List Price $ 1200 1600 NPG3D120 NPG3D160 20591.00 20591.00 1200 1600 NPG3E120 NPG3E160 22520.00 22520.00 List Price $ 12158.00 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER LCD ELECTRONIC LSI TRIP HPG3D120 21552.00 HPG3D160 21552.00 LCD ELECTRONIC LSIG TRIP HPG3E120 23481.00 HPG3E160 23481.00 Catalog Number TRIP UNIT ONLY LPG3D120 LPG3D160 23766.00 23766.00 CPT3D120 CPT3D160 11608.00 11608.00 LPG3E120 LPG3E160 25695.00 25695.00 CPT3E120 CPT3E160 13537.00 13537.00 A - Consult with Siemens for availability. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-121 MOLDED CASE CIRCUIT BREAKERS 1200 1600 ELECTRONIC LI TRIP HPG4N120 25616.00 HPG4N160 25616.00 ELECTRONIC LSI TRIP HPG4P120 26049.00 HPG4P160 26049.00 ELECTRONIC LSIG TRIP HPG4U120 28557.00 HPG4U160 28557.00 ELECTRONIC LIG TRIP HPG4X120 28123.00 HPG4X160 28123.00 List Price $ 6 Continuous Ampere Rating List Price $ VL Circuit Breakers Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames Selection Auxiliary Switch and Alarm Switch Combination Kits Description Mounting Pocket햲 Catalog Number List Price $ Left Pocket Only ASKP3 530.00 Left, Right, Neutral ASKP4 495.00 2 Aux. + 2 Alarm Switches 2A + 2B Base AMBP2 4 Aux. Switches 2A + 2B Base AMBP1 x4 Auxiliary/Alarm Switch Mounting Base Only Description Mounting Pocket햲 Catalog Number Up to 4 Auxiliary Switches 2 Aux. + 2 Alarm Switches Left, Right, Neutral Left Pocket Only AMBP1 AMBP2 List Price $ 83.00 83.00 Auxiliary/Alarm Switch Only Common to DG-PG Frames Description Catalog Number List Price $ 1 Normally Open Contact (1A) ASWPA 108.00 1 Normally Closed Contact (1B) ASWPB 108.00 x4 Shunt Trips Description Catalog Number List Price $ 24 VDC Mounting Pocket STRPB24DC 654.00 48-60 VDC STRPC60DC 654.00 STRPD125DC 654.00 STRPE250DC 654.00 48-60 VAC STRPM60 654.00 110-127 VAC STRPN120 654.00 208-277 VAC STRPS277 654.00 380-600 VAC STRPV600 654.00 Catalog Number List Price $ 110-127 VDC MOLDED CASE CIRCUIT BREAKERS 6 220-250 VDC Right Pocket Only Undervoltage Release Description Mounting Pocket 12 VDC UVRPA12DC 654.00 24 VDC UVRPB24DC 654.00 48 VDC UVRPC48DC 654.00 60 VDC UVRPG60DC 654.00 110-127 VDC UVRPD125DC 654.00 UVRPE250DC 654.00 220-250 VDC 110-127 VAC 220-240 VAC Right Pocket Only UVRPN120 654.00 UVRPR240 654.00 208 VAC UVRPP208 654.00 277 VAC UVRPS277 654.00 380-415 VAC UVRPT415 654.00 440-480 VAC UVRPU480 654.00 600 VAC UVRPV600 654.00 ‘A’ refers to a normally open contact (open when the breaker contacts are open). ‘B’ refers to a normally closed contact (closed when the breaker contacts are open). 햲 Refer to the “Accessory Locations” chart for guidelines and limitations about which pockets may be used for accessory combinations. External Accessories pages 6-125 through 6-139 6-122 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Molded Case Circuit Breakers Molded Case Switch Selection General Typically a molded case switch is used when a compact load-break switch is needed for disconnect purposes. The VL line of molded case switches from Siemens is made of the same materials and components as the VL circuit breakers but do not provide overcurrent protection. Each molded case the molded case switch. Also, the short-circuit current rating of the switch is limited to the interrupting rating of the upstream protective device or the ratings in the table below, whichever is less. switch has a fixed instantaneous selfprotecting trip element which may open the switch under high fault conditions. Application Note Overcurrent protection must be provided by an appropriate overcurrent protective device located upstream from Ordering Information Each type VL molded case switch accepts the same terminals and accessories as the equivalent VL circuit breakers. All type VL molded case switches are suitable for reverse feed applications. Mounting hardware and standard line and load terminals are included on ratings through 250A. For 400 – 1600A ratings, order the lugs separately. All ratings are UL listed and CSA certified. Molded Case Switch Maximum Ampere Rating / Frame Catalog Number List Price $ Catalog Number Short-Circuit Current Rating* List Price $ 480V 600V 150A / DG 250A / FG HDS2S150L HFS2S250L 1362.00 1618.00 HDS3S150L HFS3S250L 1447.00 1998.00 100k 100k 65k 65k 20k 35k 2,500A 3,500A 400A / JG 600A / LG HJS2S400 HLS2S600 2840.00 3973.00 HJS3S400 HLS3S600 3357.00 4970.00 100k 100k 65k 65k 35k 35k 4,400A 5,500A 800A / MG 1200A / NG HMS2S800 HNS2S120 4811.00 9172.00 HMS3S800 HNS3S120 5843.00 10002.00 100k 100k 65k 65k 35k 35k 6,500A 12,000A 1600A / PG — — HPS3S160 18017.00 100k 65k 35k 12,000A Catalog Number List Price $ 2-Pole 3-Pole LFS3S250L 2498.00 240V 200k 480V 100k 600V 25k Self Protective Instantaneous Override 3,500A 400A / JG 600A / LG LJS3S400 LLS3S600 4028.00 6863.00 200k 200k 100k 100k 42k 42k 4,400A 5,500A 800A / MG 1200A / NG LMS3S800 LNS3S120 7597.00 12003.00 200k 200k 100k 100k 50k 65k 6,500A 12,000A 1600A / PG LPS3S160 20179.00 200k 100k 65k 12,000A 3-Pole MOLDED CASE CIRCUIT BREAKERS Short-Circuit Current Rating* Maximum Ampere Rating / Frame 250A /FG 6 240V Self Protective Instantaneous Override * The Short-Circuit Current Rating is the maximum available current of the circuit where the switch is used, when protected by an appropriate overcurrent protective device. Above 250A, terminals are not included and must be ordered separately. For terminal information and the variety of lugs available for VL breakers. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-123 Molded Case Circuit Breakers Motor Circuit Protectors Selection General Protection of Motor Circuits Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be used in conjunction with motor-running, over-current protection devices, and should permit the motor to start without nuisance tripping from motor-inrush current. The circuit breaker should have a continuous current rating of not less than 115% of the motor fullload current. The recommended motor circuit protectors listed have continuous-current ratings of at least 115% of motor full-load currents. The trip setting positions are approximately 11 times motor full-load current. The suggested trip settings may need to be adjusted upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full-load current for design E motors, to allow for motor startup due to in-rush current. Breaker Mounted Immediately Ahead of Motor Starter Siemens motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protection for the motor branch circuit. The adjustable instantaneous trip feature of the Siemens motor circuit protector provides for a trip setting slightly above the peak motor in-rush current. With this setting, no delay is introduced in opening the circuit when a fault occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead of, the motor-running overcurrent protection device. Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National Electrical Code (NEC) for specific needs. Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter) 3-Phase Induction Type Motors (Siemens motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters) MOLDED CASE CIRCUIT BREAKERS 6 Motor Full Load Amperes 35-50 42-60 48-70 55-80 62-90 69-100 햲 Trip Setting (A) 450 540 630 720 810 900 58-83 69-100 81-117 92-133 104-150 115-150햳 750 900 1050 1200 1350 1500 96-139 115-150햳 135-150햳 135-150햳 135-150햳 135-150햳 1250 1500 1750 2000 2250 2500 46-67 55-80 65-93 74-107 83-120 92-133 600 720 840 960 1080 1200 77-111 92-133 108-156 123-178 138-200 154-222 1000 1200 1400 1600 1800 2000 135-194 162-210 188-220 215-241 242-250햳 242-250햳 1750 2100 2450 2800 3150 3500 Catalog Number 햲 HDM3L150L HDM3M150L HDM3H150L HFM3L250L HFM3M250L HFM3H250L List Price $ 1589.00 1589.00 1589.00 2111.00 2111.00 2111.00 Motor circuit protectors rated 150A and 250A are supplied with line and load lugs installed. If lugs are required on 400A to 1200A motor circuit breakers, order required lugs separately. 6-124 햳 Motor Full Load Amperes 96-139 115-167 135-194 154-222 173-250 192-278 Trip Setting (A) 1250 1500 1750 2000 2250 2500 154-222 185-267 215-311 246-356 277-400 308-400햳 2000 2400 2800 3200 3600 4000 154-222 185-267 215-311 246-356 277-400 308-444 2000 2400 2800 3200 3600 4000 212-306 254-367 296-428 338-489 381-550 423-600 2750 3300 3850 4400 4950 5500 250-361 292-422 335-483 385-556 442-638 500-722 3250 3800 4350 5000 5740 6500 385-556 462-667 538-778 615-889 692-1000 769-1111 5000 6000 7000 8000 9000 10,000 Catalog Number 햲 List Price $ HJM3L400 3881.00 HJM3M400 3881.00 HLM3L600 5771.00 HLM3M600 5771.00 HMM3M800 8277.00 HNM3M120 13587.00 These settings are provided for starting currents greater than 11X but not to exceed 17X. Full Load Amps ( FLA ) not to exceed ampere rating of MCP. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB External Accessories Operating Mechanisms Selection 6 MOLDED CASE CIRCUIT BREAKERS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-125 External Accessories Operating Mechanisms Description For DG to FG Frame 150 to 250 A Catalog List Number Price $ Through Door Mounted Rotary Handle Operator KitA Fixed depth and the handle is mounted directly on the circuit breaker. Lockable knob (for up to 3 padlocks). NEMA 1, 12 RHFF Red Handle Version with red knob, yellow indicator plate NEMA 1, 12 RHFFEM For JG to LG Frame 400 A to 600 A Catalog List Number Price $ 155.00 RHFL 193.00 168.00 RHFLEM 205.00 RHVF12 214.00 RHVL12 295.00 RHSFA1 RHSFA1F 187.00 187.00 RHSLA1 RHSLA1F 187.00 187.00 RHSFA2 RHSFA2F 237.00 237.00 RHSLA2 RHSLA2F 237.00 237.00 RHVFBM 131.00 RHVLBM 212.00 RHVM12H RHVM3RH RHVM4XH RHVMEMH 51.00 116.00 150.00 61.00 RHVM12H RHVM3RH RHVM4XH RHVMEMH 51.00 116.00 150.00 61.00 RHVMS02 — RHVMS12 RHVMS16 — 31.50 — 31.50 31.50 — RHVMS02 — RHVMS12 RHVMS16 — 31.50 — 31.50 31.50 — Door Mounted Rotary Handle Operator KitA Variable depth, door mounted handle. Includes knob with masking frame, indicator plate, detachable door coupling, 12" shaft, and breaker mounted rotary operator. Lockable knob (for up to 3 padlocks). NEMA 1, 12 Auxiliary Switch KitsA For Direct or Extended Rotary Handle Operators (RHF and RHV). Form C, Early Break type2 Aux. Switch Kit 햲 Includes 1 switch with 5' wire For Variable Depth For Fixed Depth Includes 2 switches with 5' wire For Variable Depth For Fixed Depth Door Mounted Rotary Operator Mechanism OnlyA 6 Breaker mechanism only MOLDED CASE CIRCUIT BREAKERS Door Mounted Rotary Handle OnlyA Standard version NEMA 1, 12 NEMA 3R NEMA 4X Red Handle version Extension Shaft Only, for Door Mounted OperatorA 2 inches (50.8mm) 3 inches (76.2mm) 12 inches (304.8 mm) 16 inches (406.4 mm) 24 inches (609.6mm) w/ support bracket 햲 During manual operation, Early Break auxiliary switch contacts open before the breaker opens. A - Consult with Siemens for availability. 6-126 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Description Through Door Mounted Rotary Handle Operator KitA Fixed depth, breaker mounted. For direct fitting to the circuit breaker. Lockable with up to 3 padlocks. NEMA 1, 12 Red Handle version with red knob, yellow indicator plate NEMA 1, 12 For MG Frame 800 A Catalog List Number Price $ For NG to PG Frame 1200 to 1600 A Catalog List Number Price $ RHFM 210.00 — — RHFMEM 226.00 — — — — — Door Mounted Rotary Handle Operator KitA Variable depth, door mounted handle. Includes knob with masking frame, indicator plate, detachable door coupling, 12" shaft, and breaker mounted rotary operator. Lockable knob (for up to 3 padlocks). NEMA 1, 12 RHVM12 322.00 — RHSMA1 RHSMA1F 187.00 187.00 RHSPA1 RHSPA1F 187.00 187.00 RHSMA2 RHSMA2F 237.00 237.00 RHSPA2 RHSPA2F 237.00 237.00 RHVMBM 239.00 RHVPBM 239.00 RHVM12H RHVM3RH RHVM4XH RHVMEMH 51.00 116.00 150.00 61.00 RHVP3RH RHVP3RH RHVP4XH RHVPEMH 116.00 116.00 150.00 126.00 RHVMS02 — RHVMS12 RHVMS16 — 31.50 — 31.50 31.50 — — RHVPS03 RHVPS12 — RHVPS24 — 97.00 97.00 — 127.00 Auxiliary Switch KitsA For Direct or Extended Rotary Handle Operators (RHF and RHV). Early Break type2 Aux. Switch Kit Includes 1 switch with 5' wire For Variable Depth For Fixed Depth Includes 2 switches with 5' wire For Variable Depth For Fixed Depth Door Mounted Rotary Operator Mechanism OnlyA Breaker mechanism only 6 Standard version NEMA 1, 12 NEMA 3R NEMA 4X Red Handle version MOLDED CASE CIRCUIT BREAKERS Door Mounted Rotary Handle OnlyA Extension Shaft Only, for Door Mounted OperatorA 2 inches (50.8mm) 3 inches (76.2mm) 12 inches (304.8 mm) 16 inches (406.4 mm) 24 inches (609.6mm) w/ support bracket A - Consult with Siemens for availability. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-127 External Accessories Operating Mechanisms Description For DG and FG Frame 150 to 250 A Catalog List Number Price $ For JG and LG Frame 400 to 600 A Catalog List Number Price $ Variable Depth Flange Mounted Operator KitA Adjustable from 8" to 16" Complete kit, includes handle and variable depth operator. NEMA 1, 3R, 12 NEMA 4X IEC Black Handle NEMA 1, 3R, 12 FHVF3R FHVF4X FHVF3RB 275.00 368.00 275.00 FHVL3R FHVL4X FHVL3RB 294.00 391.00 294.00 MFKF3R 588.00 MFKL3R 630.00 MFHM3R MFHM3RS MFHM4X 269.00 315.00 432.00 MFHM3R MFHM3RS MFHM4X 269.00 315.00 432.00 MFHM3RB 269.00 MFHM3RB 269.00 MFHM3RSB 315.00 MFHM3RSB 315.00 MFMF 194.00 MFML 218.00 Cable Only, for Max-Flex™ Variable DepthA 36" 48" 60" 72" 84" 96" 120" 144" MFCF036 MFCF048 MFCF060 MFCF072 MFCF084 MFCF096 MFCF120 MFCF144 161.00 192.00 217.00 239.00 264.00 287.00 376.00 417.00 MFCM036 MFCM048 MFCM060 MFCM072 MFCM084 MFCM096 MFCM120 MFCM144 177.00 209.00 239.00 275.00 319.00 376.00 408.00 424.00 Handle Auxiliary SwitchA Form C (1NO - 1NC), early break햳 1 Aux. switch 2 Aux. switch MFSFA1 MFSFA2 165.00 330.00 MFSLA1 MFSLA2 165.00 330.00 Max-Flex™, Variable Depth Flange Mounted Operator KitA Complete kit, includes handle, breaker operator, and cable. NEMA 1, 3R, 12 For DG and FG operators, the cable is 36", all others are 48" Handle Only, for Max-Flex™ Variable DepthA NEMA 1, 3R, 12 Plastic NEMA 1, 3R, 12 Steel - epoxy coated NEMA 4, 4X Steel - chrome plated Solid color (all gray) Plastic햲 NEMA 1, 3R, 12 Solid color (black handle) Steel epoxy coated햲 NEMA 1, 3R, 12 MOLDED CASE CIRCUIT BREAKERS 6 Breaker Operator Mechanism Only, for Max-Flex™ A 햲 Max-Flex™ handles are available with solid gray or black handles instead of the customary “Red for On” flange handle. The black handle is preferred for IEC markets, where red handles have a specific meaning. During manual operation, Early Break aux. contacts open before the breaker opens. A - Consult with Siemens for availability. 햳 6-128 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB Description For MG Frame 800 A Catalog List Number Price $ For NG Frame 1200 A Catalog List Number Price $ For PG Frame 1600 A Catalog Number Variable Depth Flange Mounted Operator KitA Adjustable from 8" to 16" Complete kit, includes handle and variable depth operator. NEMA 1, 3R, 12 NEMA 4X IEC Black Handle NEMA 1, 3R, 12 — — — — — — — — — Max-Flex™, Variable Depth Flange Mounted Operator KitA Complete kit, includes handle, breaker operator, and cable. NEMA 1, 3R, 12 For DG and FG operators, the cable is 36", all others are 48" — — — — — — List Price $ — — — MFKM3R 736.00 MFKP3RS 839.00 MFKP3RS 839.00 MFHM3R MFHP3RS MFHM4X 269.00 470.00 432.00 — MFHP3RS MFHP4X — 470.00 630.00 — MFHP3RS MFHP4X — 470.00 630.00 MFHM3RB 269.00 — MFHM3RSB 315.00 MFHP3RSB 470.00 MFHP3RSB 470.00 MFMM 218.00 MFMP 218.00 MFMP 218.00 Cable Only, for Max-Flex™ Variable DepthA 36" 48" 60" 72" 84" 96" 120" 144" MFCM036 MFCM048 MFCM060 MFCM072 MFCM084 MFCM096 MFCM120 MFCM144 177.00 209.00 239.00 275.00 319.00 376.00 408.00 424.00 — MFCP048 MFCP060 MFCP072 MFCP084 MFCP096 MFCP120 MFCP144 — 237.00 275.00 320.00 337.00 401.00 437.00 588.00 — MFCP048 MFCP060 MFCP072 MFCP084 MFCP096 MFCP120 MFCP144 — 237.00 275.00 320.00 337.00 401.00 437.00 588.00 Handle Auxiliary SwitchA Form C (1NO - 1NC), early break햳 1 Aux. switch 2 Aux. switch MFSPA1 MFSPA2 Handle Only, for Max-Flex™ Variable DepthA NEMA 1, 3R, 12 Plastic NEMA 1, 3R, 12 Steel - epoxy coated NEMA 4, 4X Steel - chrome plated Solid color (all gray) Plastic햲 NEMA 1, 3R, 12 Solid color (black handle) Steel epoxy coated햲 NEMA 1, 3R, 12 Breaker Operator Mechanism Only, for Max-Flex™ A CSO CSO MFSPA1 MFSPA2 — MOLDED CASE CIRCUIT BREAKERS MFSPA1 MFSPA2 — 6 CSO CSO — CSO CSO A - Consult with Siemens for availability. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-129 External Accessories Operating Mechanisms For DG to FG Frame 150 to 250 A Catalog List Number Price $ Description Stored Energy and Motor Operators Lockable with up to 3 padlocks. AC Voltage — 42-48 60 110–127 220–250 DC Voltage 24 42-48 60 110–127 220–250 Cylinder Locks for Field Installation Plug-In and Draw-Out Bases 120.00 For FG Frame 250 A Catalog Number PCBDRC3 351.00 PCBFRC3 691.00 PCBDFC3 351.00 PCBFFC3 691.00 DCADRC3 944.00 DCAFRC3 1194.00 DCADFC3 944.00 DCAFFC3 1194.00 Hex Wrench for racking draw-out assembly and position indicator DCHP 134.00 DCHP 134.00 Position Indicator Switch Form “C” switch to indicate breaker engaged/de-engaged position.햲 DCIP 156.00 DCIP 156.00 Secondary Terminal Block Assy. Accessory connections for plug-in or draw-out breakers. Pre-wired plug and block with 8 terminal points.햳 PCTF83 109.00 PCTF83 109.00 90° Connection Adapter Kit For rear connected 3-pole plug-in base PCAF390 Plug-In Spare Breaker Kit Set of 6 terminal blades, 2 terminal shield, & 1 trip interlock PCXD3 242.00 PCXF3 320.00 Draw-out Spare Breaker Kit Set of 6 terminal blades, & 1 trip interlock DCXD3 210.00 DCXF3 289.00 Spare BreakerTrip Interlock PCXFT 21.00 PCXFT 21.00 Plug-in Mounting Base Assembly Includes base, terminal blade kit, sec. terminal block assembly, base trip interlock, and mounting hardware. Rear Connected 3-pole Front Connected 3-pole Draw-out Assembly Includes base, position indicator switch, socket, base trip interlock, crank handle, connectors, and necessary shields. Rear Connected 3-pole Front Connected 3-pole (Draw-out assembly includes side plates and all hardware) 6 CLKF For DG Frame 150 A Catalog List Number Price $ Description MOLDED CASE CIRCUIT BREAKERS Stored Energy Type SEAFB 1915.00 SEAFM 1915.00 SEAFY 1915.00 SEAFN 1915.00 SEAFR 1915.00 74.00 PCAF390 74.00 햲 Up to 2 position indicator switches may be mounted per plug-in or draw-out base. Up to 2 plugs per breaker (16 terminal points) may be mounted on DG, and FG breakers. Up to 3 plugs per breaker (24 terminal points) may be mounted on JG, LG, MG, NG, and PG breakers. A - Consult Siemens for availability. 햳 6-130 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB For JG to LG Frame 400 to 600 A Catalog List Number Price $ For MG Frame 800 A Catalog List Number Price $ For NG to PG Frame 1200 to 1600 A Catalog List Number Price $ Stored Energy SEALB SEALM SEALY SEALN SEALR Stored Energy SEAMB SEAMM SEAMY SEAMN SEAMR Motor Operator MTRPB MTRPM MTRPY MTRPN MTRPR CLKP Type 3525.00 3525.00 3525.00 3525.00 3525.00 120.00 CLKP For JG Frame 400 A Catalog List Number Price $ For LG Frame 600 A Catalog Number PCBJRC3 1179.00 PCBJFC3 Type 4173.00 4173.00 4173.00 4173.00 4173.00 120.00 CLKP Type 4457.00 4457.00 4457.00 4457.00 4457.00 120.00 List Price $ For MG Frame 800 A Catalog List Number Price $ For NG Frame 1200 A Catalog List Number Price $ For PG Frame 1600 A Catalog Number PCBLRC3 1865.00 PCBMRC3 PCBNRC3 3909.00 — — 1179.00 PCBLFC3 1865.00 — — — — DCAJRC3 1881.00 DCALRC3 2886.00 DCAMRC3 4337.00 DCAPRC3 5566.00 DCAPRC3 5566.00 DCAJFC3 1881.00 DCALFC3 2886.00 DCAMFC3 4337.00 DCAPFC3A 5566.00 DCAPFC3A 5566.00 2891.00 — — List Price $ DCHP 134.00 DCHP 134.00 DCHP 134.00 DCHP 134.00 DCIP 156.00 DCIP 156.00 DCIP 156.00 DCIP 156.00 DCIP 156.00 PCTL83 133.00 PCTL83 133.00 PCTM83 143.00 PCTP83 168.00 PCTP83 168.00 — — — — — — — — — — — PCXJ3 410.00 PCXL3 483.00 PCXM3 1085.00 PCXN3 1344.00 — DCXJ3 378.00 DCXL3 452.00 DCXM3 1050.00 DCXN3 1307.00 DCXP3 1307.00 PCXLT 23.00 PCXLT 23.00 PCXMT 58.00 PCXPT 77.00 PCXPT 77.00 Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-131 MOLDED CASE CIRCUIT BREAKERS 134.00 6 DCHP External Accessories Connections Description For DG Frame 150 A Catalog List Number Price $ For FG Frame 250 A Catalog List Number Price $ FBCD3 — FBCF3 — Front Bus Bar Connections햲 Includes nut keeper plates and shield. Standard 3-Pole Set Round Terminal 6 Flat Terminal MOLDED CASE CIRCUIT BREAKERS Flat Bus Bar Standard (straight) 3-Pole Set Bus Bar Connection Strap Kit Includes 6 - Bus Bars, 6 Nut Keepers & Shields 100% rated applications CSO — CSO — Rear-Connecting Studs Short length round term. (1piece) Long length round term. (1piece) 3-Pole round term. kit, 2 short + 1 long Short length flat term. (1piece) Long length flat term. (1piece) 3-Pole flat term. kit, 2 short + 1 long Flat bus bar type (1 piece) 3-Pole set of flat bus bar RTLDSR RTLDLR SRTDR3 RTLDSF RTLDLF SRTDF3 — — Terminal Shields햲 Includes 1 terminal shield, for line or load. 3-Pole Standard Shield TSSF3 37.00 TSSF3 37.00 TSLF3 58.00 TSLF3 58.00 Interphase Barriers햲 Set of 2 barriers Also fits plug-in and draw-out bases. IPBF 29.00 IPBF 29.00 Lug Mounting Assy. — — — — — — — — — — — — 3-Pole Extended Shield 83.00 112.00 277.00 83.00 112.00 277.00 — — RTLFSR RTLFLR SRTFR3 RTLFSF RTLFLF SRTFF3 — — 83.00 112.00 277.00 83.00 112.00 277.00 — — Breaker Mounting Base Front connected Rear connected Terminal Shields Interphase Barriers 햲 Not UL listed. A - Consult Siemens for availability. 6-132 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB For JG Frame 400 A Catalog List Number Price $ For LG Frame 600 A Catalog List Number Price $ For MG Frame 800 A Catalog List Number Price $ For NG Frame 1200 A Catalog List Number Price $ For PG Frame 1600 A Catalog List Number Price $ FBCJ3A — FBCL3A — FBCM3A — FBCP3A SSBP SSBPH CSO 1004.00 1227.00 FBCP3A SSBP SSBPH — — — — — — RTLNSF SRTNF3 — — — — — — 434.00 1303.00 — — — — — — — — RTLJSR RTLJLR SRTJR3 RTLJSF RTLJLF SRTJF3 — — CSO — CSO — CSO — CSO 1004.00 1227.00 195.00 208.00 597.00 195.00 208.00 597.00 — — — — — — — — RTLLSF SRTLF3 — — — — — — 224.00 671.00 — — — — — — RTLMSF SRTMF3 — — — — — — 323.00 967.00 — — — — — — — — TSSL3 47.50 TSSL3 47.50 TSSM3 67.00 TSSP3 91.00 TSSP3 91.00 TSLL3 68.00 TSLL3 68.00 TSLM3 97.00 TSLP3 116.00 TSLP3 116.00 IPBM 38.50 IPBM 38.50 IPBM 38.50 IPBP 83.00 IPBP — — — — — — — — LMAP1600 968.00 — — — — — — — — — — — — — — — — MBPG1600 MBPG1601 1211.00 1211.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-133 83.00 MOLDED CASE CIRCUIT BREAKERS Discount Schedule MCCB 6 A - Consult with Siemens for availability. External Accessories Connections Discription For DG Frame 150 A Catalog Number Nut Keeper Plates For ring/tongue terminal or bus bar connections. (For metric threads on other than the JG or LG frame, change ”TNK” to ”TMK”) 1 Nut Keeper Plate Kit of 3 TNKD TNKD3 6.10 19.40 TNKF TNKF3 Mechanical Lugs Steel Wrap Around Body (Cu Wire Only) Cable Size; (cables per phase) Single Lug Kit of 3 #8-1/0; 1-hole TW1DG20 3TW1DG20 7.20 22.00 #4-350 kcmil; 1-hole TW1FG350 22.00 3TW1FG350 65.00 Aluminum Body (Al or Cu Wire) Cable Size; (cables per phase) Single Lug Kit of 2 #6-3/0; 1-hole TA1DG30 — 7.20 — #4-350 kcmil; 1-hole TAW1FG350 22.00 — — Kit of 3 3TA1DG30 22.00 3TAW1FG350 65.00 Cable Size; (cables per phase) — — — — Single Lug Kit of 2 Kit of 3 — — — — — — — — — — — — Cable Size; (cables per phase) Single Lug — — — — — — — — Kit of 3 — — — — #6-3/0; 1-hole TC1DG30 — 33.50 — #4-350 kcmil; 1-hole TCW1FG350 34.50 — — MOLDED CASE CIRCUIT BREAKERS 6 Copper Body (Cu Wire Only) Cable Size; (cables per phase) Single Lug Kit of 2 101.00 List Price $ 3TCW1FG350 6.10 19.40 Kit of 3 3TC1DG30 Cable Size; (cables per phase) Single Lug — — — — — — #14-2/0; 1-cable 2CLD20 3CLD20 54.00 81.00 #6-350 kcmil; 1-cable 2CLF350 102.00 3CLF350 152.00 — — — — — Compression Lugs Cable Size; (cables per phase) Kit of 2 Kit of 3 Cable Size; (cables per phase) Kit of 2 Kit of 3 — — — — — Cable Size; (cables per phase) Kit of 3 — — — — — — Distribution Lugs Cable Size; (cables per phase) Single Lug Kit of 3 Cable Size; (cables per phase) Single Lug Kit of 3 6-134 List Price $ For FG Frame 250 A Catalog Number #14-#2; 3-hole TA3DG02 3TA3DG02 #14-#4; 6-hole TA6DG04 3TA6DG04 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 31.50 110.00 33.50 110.00 #14-#1; 2-hole and #14-2/0; 1-hole TA3FG20 3TA3FG20 #14-#4; 6-hole TA6FG04 3TA6FG04 104.00 — — 37.00 110.00 37.00 110.00 Discount Schedule MCCB For JG Frame 400 A Catalog Number TMKJ TMKJ3 List Price $ List Price $ For MG Frame 800 A Catalog Number List Price $ For NG Frame 1200 A Catalog Number List Price $ For PG Frame 1600 A Catalog Number List Price $ TNKL TNKL3 9.80 29.00 TNKM TNKM3 9.80 29.00 TNKP TNKP3 9.80 29.00 TNKP TNKP3 9.80 29.00 1/0-500 kcmil; 1-hole TW1JG600 29.00 3TW1JG600 87.00 — — — — — — — — — — — — — — — — — — — — — — — — 3/0-250 kcmil; 2-hole TA2JG250 29.00 — — #2-600 kcmil; 2-hole — — 2TA2LG600LD햲 72.00 2TA2LG600LN햳 72.00 3TA2LG600LD햲 109.00 3TA2LG600LN햳 109.00 3TA2JG250 6.10 19.40 For LG Frame 600 A Catalog Number 87.00 1/0-500 kcmil, 3-hole TA3MG500 67.00 3TA3MG500 202.00 AL: 250-750 kcmil CU: 3/0-600 kcmil; 1-hole TA1JG750 36.00 — — 3TA1JG750 109.00 AL: 250-750 kcmil CU: 3/0-600 kcmil; 1-hole TA1JG750 (400A max) 36.00 — — 3TA1JG750 (400A max)109.00 500 -750 kcmil; 2-hole TA2MG750 122.00 — — 3TA2MG750 364.00 — — — — — — — — #2-600 kcmil; 3-hole — — — — — — 3TA3MG600햵 3/0-250 kcmil; 2-hole TC2JG250 77.00 — — #6-350 kcmil; 2-cable — — 6CLL350 899.00 250-750 kcmil; 1-cable — — 3CLJ750 449.00 3TA4NG500 3TA4NG500H햴 3TA6PG750햶 291.00 875.00 500 -750 kcmil; 3-hole TA3NG750 106.00 2TA3NG750 579.00 3TA3NG750 832.00 — — 940.00 600-750 kcmil; 4-hole TA4P750햷 254.00 — — 300-600 kcmil; 5; 6-hole 320.00 TA5P600햷 TA6R600햷 338.00 — — 1/0-500 kcmil; 3-hole TC3MG500 134.00 — — 1/0-500 kcmil; 4-hole — — — — 1/0-750 kcmil; 6-hole — — — — — — 3TC4NG500 3TC6PG750 (future) 1342.00 — — — — 1/0-500 kcmil; 3-hole TC3NG500 CSO 300-600 kcmil; 5-hole TC5R600햷 426.00 1/0-500 kcmil; 3-cable — — 9CLM500 (future) 1056.00 1/0-500 kcmil; 4-cable — — 12CLN500 1393.00 #2-600 kcmil; 8-cable — — 24CLP600 (future) 2787.00 250 kcmil-750 kcmil; 1-cable — — 3CLL750 494.00 — — — — — — — — — — — — — — — — 250-600 kcmil; 1-cable 3CLJ600 449.00 250 kcmil-600 kcmil; 2-cable 6CLL600 899.00 — — — — — — — — — — — — #14-#4; 12-hole TA12JG04 3TA12JG04 #14-2/0; 6-hole TA6JG20 3TA6JG20 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 88.00 265.00 88.00 265.00 — — — — — — 832.00 All lug kits include the nut keepers. 햲 Mounted on Load Side Only. 햳 Mounted on Line Side Only. 햴 Rated 90° for 100% Applications. 햵 Requires extended modified shield. 햶 Used only with LMAP 1600 mounting base. 햷 Used with MBPG 1600 or 1601 mounting base. Discount Schedule MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-135 MOLDED CASE CIRCUIT BREAKERS #6-350 kcmil; 1-cable — — 3CLJ350 449.00 1/0-750 kcmil; 6-hole — — — — 6 3/0-750 kcmil; 1-hole TC1JG750 77.00 #2-600 kcmil; 2-hole — — 2TC2LG600LD햲 154.00 2TC2LG600LN햳 154.00 3TC2LG600LD햲 231.00 햳 3TC2LG600LN 231.00 — — — — 218.00 1/0-500 kcmil; 4-hole — — 2TA4NG500 579.00 External Accessories General For DG Frame 150 A Catalog List Number Price $ For FG Frame 250 A Catalog List Number Price $ Handle Padlocking Device To padlock breaker toggle in the “OFF” position. Accepts up to 3 padlocks with 5–8 mm shackles. HPLF 15.80 HPLF 15.80 Handle Blocking Device For holding the handle in the “ON” or “OFF” position. Not a lockout/tagout device. HBDF 27.00 HBDF 27.00 Description Handle Padlocking Device MOLDED CASE CIRCUIT BREAKERS 6 Walking-Beam Interlock Mechanism Cable Interlock System 6-136 Walking-Beam Interlock Mechanism Provides mechanical interlocking between two adjacent circuit breakers. Fixed mounted breakers Plug-in or draw-out mounted breakers (Future) Note: Both breakers must be of the same frame size. Cable Interlock Mechanism Provides mechanical interlocking between 2 circuit-breakers includes operator mechanism for one circuit breaker only. Combination with the next larger or smaller frame size is possible. Interlock Cable Cable only, to connect 2 circuit breakers. Cable length 18 in. .46m (recommended up to 250A) Cable length 36 in. .91m (recommended from 600–800A) Cable length 54 in. 1.37m (recommended from 1200–1600A) WBMFFM WBMFDP 608.00 603.00 WBMFFM WBMFDP 608.00 603.00 CBTF 481.00 CBTF 481.00 CBCF18 CBCM36 CBCP54 134.00 156.00 190.00 CBCF18 CBCM36 CBCP54 134.00 156.00 190.00 Mounting Screw Kit Includes the necessary hardware to mount a circuit breaker to the user’s prepared surface (SAE thread) Kit with 2 screws Kit with 4 screws MSKF2 MSKF4 Trip Adjustment Sealing Cover Includes a trip unit cover to prevent tampering or adjustment of trip settings. Seal not included. Electronic Trip Units Thermal-Magnetic Trip Units TSCPET TSCFTM Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3.70 3.70 15.80 38.50 MSKF2 MSKF4 TSCPET TSCFTM 3.70 3.70 15.80 38.50 Discount Schedule MCCB For JG Frame 400 A Catalog List Number Price $ For LG Frame 600 A Catalog List Number Price $ For MG Frame 800 A Catalog List Number Price $ For NG Frame 1200 A Catalog List Number Price $ For PG Frame 1600 A Catalog List Number Price $ HPLL 22.00 HPLL 22.00 HPLM 57.00 HPLP 57.00 HPLP 57.00 HBDL 27.00 HBDL 27.00 HBDM 57.00 HBDP 57.00 HBDP 57.00 WBMLFM WBMLDP 608.00 603.00 WBMLFM WBMLDP 608.00 603.00 WBMMFM WBMMDP 608.00 603.00 WBMPFM WBMPDP 658.00 658.00 WBMPFM WBMPDP 658.00 658.00 CBTL 515.00 CBTL 515.00 CBTM 548.00 CBTP 582.00 CBTP 582.00 — CBCM36 CBCP54 — 156.00 190.00 — CBCM36 CBCP54 — 156.00 190.00 — CBCM36 CBCP54 — 156.00 190.00 — — CBCP54 — — 190.00 — — CBCP54 — — 190.00 — 10.90 — MSKL4 — 10.90 — MSKM4 — 15.80 — MSKP4 — 29.00 — MSKP4 — 29.00 TSCPET TSCLTM 15.80 38.50 TSCPET TSCLTM 15.80 38.50 TSCPET TSCMTM 15.80 38.50 TSCPET — 15.80 — TSCPET — 15.80 — 6 — MSKL4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-137 MOLDED CASE CIRCUIT BREAKERS Discount Schedule MCCB External Accessories Ground Sensors & Electronic Accessories Description For DG Frame 150 A Catalog Number Neutral Current Transformer (Ground Sensor, N-pole) Neutral = 35/60A Neutral = 100A Neutral = 150A Neutral = 250A Neutral = 400A Neutral = 600A Neutral = 800A Neutral = 1000/1200A Neutral = 1600A NGSD060 NGSF100 NGSF150 — — — — — — 402.00 402.00 402.00 — — — — — — — NGSF100 NGSF150 NGSJ250 — — — — — — 402.00 402.00 402.00 — — — — — EPSP18V 582.00 EPSP18V 582.00 Test Kit - Portable power supply for programming, trip test, and checking CT’s plus a port for local communications of currents flow and trip settings. (Requires two 9V batteries) ELTPHB Universal Power Supply - 120/240Vac adapter used in lieu of 9V batteries for Test Kit ELTPHB (includes necessary cables) UPAPELTK Power Supply with ZSI (for Model 576 trip units only). COMPS 2013.00 COMPS 2013.00 Com10 Profibus Communications Module with ZSI for LCD trip Model 576 only COMPRO 2684.00 COMPRO 2684.00 Com11 Modbus Communications Module with ZSI for LCD Trip Model 576 only COMMOD 2684.00 COMMOD 2684.00 Communications Adapter - Interface with a laptop or PC to test or program Model 545 & 576 trip units CSAPELTU 911.00 CSAPELTU 911.00 Cable for COM10/11 and Model 576 external power supply……5ft. (1.5m) COMKIT1 179.00 COMKIT1 179.00 Extension cable for COMKIT1 & COMKIT2, adds 5 ft. COMEXT 134.00 COMEXT 134.00 Spare flat cable for Test Kits or Communications Adapters COMPCA 358.00 COMPCA 358.00 RS232 type cable for Test Kits or Communications Adapters COMP232 179.00 COMP232 179.00 Cover Frame for Door Cutout For fixed or plug-in mounted circuit breakers. (IP30) 2-Pole & 3-Pole BZLF3 224.00 BZLF3 224.00 For breakers with stored energy operator. (IP40) BZLFRHSE 224.00 BZLFRHSE 224.00 (not for use with rotary handle or stored energy operator) BZLFBDC 224.00 BZLFBDC 224.00 Toggle Handle Extension For spare or replacement. (One is included with each LG - PG frame.) — Spare Flat Cable Power Stick RS232 Cable Com10 Profibus & Com11 Modbus Communications Module 3428.00 537.00 ELTPHB List Price $ 6 List Price $ MOLDED CASE CIRCUIT BREAKERS Communications & Electronics Power Stick - Hand held, battery operated power supply for LCD trip units. (Requires two -9V batteries) For programming and trip testing only. For FG Frame 250 A Catalog Number UPAPELTK 3428.00 537.00 Door Cutouts & Extensions Cover Frame for Door Cutout Circuit-breaker draw-out mounted and toggle handle operated. Kit includes cover frame (bezel) and escutcheon as needed. (IP40) — — — Toggle Handle Extension 6-138 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule MCCB For JG Frame 400 A Catalog List Number Price $ For LG Frame 600 A Catalog Number List Price $ For MG Frame 800 A Catalog List Number Price $ For NG Frame 1200 A Catalog List Number Price $ For PG Frame 1600 A Catalog List Number Price $ — — — NGSJ250 NGSL400 — — — — — — — 402.00 402.00 — — — — — — — — NGSL400 NGSM600 — — — — — — — 402.00 402.00 — — — — — — — — NGSM600 NGSN800 — — — — — — — 402.00 402.00 — — — — — — — — NGSN800 NGSP120 — — — — — — — 402.00 402.00 — — — — — — — — NGSP120 NGSP160 — — — — — — — 402.00 402.00 EPSP18V 582.00 EPSP18V 582.00 EPSP18V 582.00 EPSP18V 582.00 EPSP18V 582.00 ELTPHB UPAPELTK 3428.00 537.00 ELTPHB UPAPELTK 3428.00 537.00 ELTPHB UPAPELTK 3428.00 537.00 ELTPHB UPAPELTK 3428.00 537.00 ELTPHB UPAPELTK 3428.00 537.00 COMPS 2013.00 COMPS 2013.00 COMPS 2013.00 COMPS 2013.00 COMPRO 2684.00 COMPRO 2684.00 COMPRO 2684.00 COMPRO 2684.00 COMPRO 2684.00 COMMOD 2684.00 COMMOD 2684.00 COMMOD 2684.00 COMMOD 2684.00 COMMOD 2684.00 CSAPELTU 911.00 CSAPELTU 911.00 CSAPELTU 911.00 CSAPELTU 911.00 CSAPELTU 911.00 COMKIT2 179.00 COMKIT2 179.00 COMKIT2 179.00 COMKIT1 179.00 COMKIT1 179.00 COMEXT 134.00 COMEXT 134.00 COMEXT 134.00 COMEXT 134.00 COMEXT 134.00 COMPCA 358.00 COMPCA 358.00 COMPCA 358.00 COMPCA 358.00 COMPCA 358.00 COMP232 179.00 COMP232 179.00 COMP232 179.00 COMP232 179.00 COMP232 179.00 BZLL3 224.00 BZLL3 224.00 BZLM3 279.00 BZLP3 279.00 BZLP3 279.00 BZLLRHSE 224.00 BZLLRHSE 224.00 BZLMRHSE 279.00 BZLPRHSE 279.00 BZLPRHSE 279.00 BZLLBDC 224.00 BZLLBDC 224.00 BZLMBDC 279.00 BZLPBDC 279.00 BZLPBDC 279.00 THEM 105.00 THEP 105.00 THEP 105.00 THEL 63.00 THEL Discount Schedule MCCB 63.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-139 MOLDED CASE CIRCUIT BREAKERS 2013.00 6 COMPS Molded Case Circuit Breakers Accessory Locations Selection Locations of Internally Mounted Accessories Frame Family DG*, FG*, JG, LG Left Pocket Right Pocket Up to 3 Auxiliary Switches 150 to 600A Up to 2 Auxiliary Switches + 1 Alarm Swich MG, NG, PG Shunt Trip or UVR or up to 3 Auxiliary Switches or up to 2 Auxiliary Switches + 1 Alarm Switch Shunt Trip or UVR or up to 3 Auxiliary Switches or up to 2 Auxiliary Switches + 1 Alarm Switch Up to 4 Auxiliary Switches Shunt Trip or UVR or up to 4 Auxiliary Switches Up to 2 Auxiliary Switches + 2 Alarm Swiches Shunt Trip or UVR or up to 4 Auxiliary Switches 800 to 1600A MOLDED CASE CIRCUIT BREAKERS 6 * Except DG and FG breakers with Electronic Trip Units. Due to the location of the Magnetic Latch, the Left Pocket is not available for accessories. Accessory Information ▪ Aux. Switch is an Auxiliary Switch, 1A or 1B contact ▪ Alarm Switch has 1A or 1B contact ▪ UVR is an Undervoltage Release ▪ The standard location for factory mounted Auxiliary and Alarm Switches is the Left Pocket ▪ For 4-pole breakers, the 4th pole (located on the far left) can hold up to 3 Auxiliary Switches on DG, FG, JG, and up to 4 Auxiliary Switches on MG, NG, and PG breakers 6-140 Accessory Maximums DG, FG, JG, LG Maximum Accessories: ▪ Maximum of six (6) switches total ▪ DG, FG Maximum of two (2) Alarm Switches, one each in the Left and Right Pockets. JG, LG Max. of 1 Alarm, Left only ▪ Maximum of three (3) switches combined in 4th Pole and Left Pockets MG, NG, PG Maximum Accessories: ▪ Maximum of eight (8) switches total ▪ Maximum of two (2) Alarm Switches, Left Pocket only ▪ Maximum of four (4) switches combined in 4th Pole and Left Pockets Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Molded Case Circuit Breakers Selection Suffix for factory mounted Switch Combinations If the frame is: DG, FG, JG or LG And you need these functions: 1 Alarm Switch 1 NO Alarm 1 NC Alarm Then add this suffix: Device Catalog Number A1 ASKL1 DG, FG, JG or LG 2 Aux. Switches 1 NO + 1 NC Aux. Contacts A2 ASKL2 DG, FG, JG or LG 2 Aux. + 1 Alarm Switches 1NO + 1NC Aux. and 1NO Alarm 1NO + 1NC Aux. and 1NC Alarm 2NO Aux. and 1NC Alarm 2NC Aux. and 1NO Alarm A3 ASKL3 MG, NG or PG 2 Aux. + 2 Alarm Switches 1NO + 1NC Aux. and 1NO + 1NC Alarm 2NO Aux. and 2NC Alarm 2NC Aux. and 2NO Alarm A3 ASKP3 MG, NG or PG 4 Aux. Switches 2NO + 2NC Aux. A4 ASKP4 And you need these functions: 24V DC 48-60V DC 110-127V DC 220-250V DC 48-60V AC 110-127V AC 208-277V AC 380-600V AC Then add this suffix: RB RC RD RE RM RN RS RV Device Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 24V DC 48-60V DC 110-127V DC 220-250V DC 48-60V AC 110-127V AC 208-277V AC 380-600V AC RB RC RD RE RM RN RS RV STRPB24DC STRPC60DC STRPD125DC STRPE250DC STRPM60 STRPN120 STRPS277 STRPV600 And you need these functions: 12V DC 24V DC 48V DC 60V DC 110-127V DC 220-250V DC 110-127V AC 220-240V AC 208V AC 277V AC 380-415V AC 440-480V AC 600V AC Then add this suffix: UA UB UC UG UD UE UN UR UP US UT UU UV Device Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 UVRLV600 12V DC 24V DC 48V DC 60V DC 110-127V DC 220-250V DC 110-127V AC 220-240V AC 208V AC 277V AC 380-415V AC 440-480V AC 600V AC UA UB UC UG UD UE UN UR UP US UT UU UV UVRPA12DC UVRPB24DC UVRPC48DC UVRPG60DC UVRPD125DC UVRPE250DC UVRPN120 UVRPR240 UVRPP208 UVRPS277 UVRPT415 UVRPU480 UVRPV600 Suffix for factory mounted Shunt Trips If the frame is: DG, FG, JG or LG 6 MOLDED CASE CIRCUIT BREAKERS MG, NG or PG Suffix for factory mounted Under Voltage Releases If the frame is: DG, FG, JG or LG MG, NG or PG Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-141 Technical Data MOLDED CASE CIRCUIT BREAKERS 6 Max rated continuous current Rated operational voltage NEMA IEC Rated Impulse Withstand Voltage Main conducting paths Auxiliary circuits Ambient Temperature Range High Ambient Derating (thermal-mag.) DG FG JG LG MG NG PG 150 250 400 600 800 1200 1600 V AC V AC 600 690 600 690 600 690 600 690 600 690 600 690 600 690 kV kV ºC 50ºC 60ºC 70ºC 8 4 -25 to +75 93% 86% 80% 20,000 120 8 4 -25 to +75 93% 86% 80% 20,000 120 8 4 -25 to +75 93% 86% 80% 20,000 120 8 4 -25 to +75 93% 86% 80% 10,000 60 8 4 -25 to +75 95% 86% 80% 5,000 60 8 4 -25 to +75 95% 86% 80% 3,000 30 8 4 -25 to +75 95% 80% 74% 3,000 30 15 – 48 40 32 – 80 60 60 – 175 90 85 – 230 160 170 – 250 250 150 – 220 210 200 – 260 260 — — — — — — — 30 30 30 30 42 42 42 18 25 35 35 65 65 65 10 5 10 5 10 5 10 5 10 5 10 5 10 5 V 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 VA VA VA VA W W W W ms 401 – 501 424 – 489 533 – 736 408 – 645 594 740 – 925 559 – 648 722 – 820 50 401 – 501 424 – 489 533 – 736 408 – 645 594 740 – 925 559 – 648 722 – 820 50 401 – 501 424 – 489 533 – 736 408 – 645 594 740 – 925 559 – 648 722 – 820 50 401 – 501 424 – 489 533 – 736 408 – 645 594 740 – 925 559 – 648 722 – 820 50 401 – 501 424 – 489 533 – 736 408 – 645 594 740 – 925 559 – 648 722 – 820 50 401 – 501 424 – 489 533 – 736 408 – 645 594 740 – 925 559 – 648 722 – 820 50 401 – 501 424 – 489 533 – 736 408 – 645 594 740 – 925 559 – 648 722 – 820 50 Operating Cycles Max switching rate (per hour) Power loss (at max. rated current) Thermal-magnetic W Electronic trip unit W IEC ��� Time constant t = 10 ms 1 current path 2 current paths 3 current paths in series in series Up to 250V DC 440V DC 600V DC NEMA Time constant t = 8 ms 2 poles switching 1 current path 250V DC Max. ��� 3 poles switching 2 current paths in series 500V DC Max. ��� Accessories Auxiliary / Alarm Switch Current rating (1 or 2 switches) Current rating (3 or 4 same switch) A Shunt Trip Pick-up voltage Power Consumption (short-time) at: 48 – 60 V AC 110 – 127 V AC 208 – 277 V AC 380 – 600 V AC 24 V DC 48 – 60 V DC 110 –127 V DC 220 – 250 V DC Max. Operating time ��� ��� Consult Siemens for short circuit values. Review individual frame and type values. 6-142 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Technical Data Undervoltage Trip Drop voltage (percentage) Pick-up voltage (percentage) Power consumption (continuous) at: 110 – 127 V AC VA 220 – 250 V AC VA 208 V AC VA 277 V AC VA 380 – 415 V AC VA 440 – 480 V AC VA 500 – 525 V AC VA 600 V AC VA Max. opening time FG V V 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 ms ms ms s s VA/W JG LG MG NG PG 35% – 70% 35% – 70% 35% – 70% 70% – 85% 70% – 85% 70% – 85% 35% – 70% 70% – 85% 35% – 70% 35% – 70% 70% – 85% 70% – 85% 35% – 70% 70% – 85% 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1.1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1.1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 1.1 2.1 1.2 1.4 1.9 2.2 2.5 2.8 50 50 X X X X 120 20 – 50 <100 <5 <5 <500 120 20 – 50 <100 <5 <5 120 20 – 50 <100 <5 <5 60 20 – 50 <100 <5 <5 X X 60 20 – 50 <100 <5 <5 X X 30 — <5,000 <5 <5 X 30 — <5,000 <5 <5 6 Motorized Operating Mechanism Motor with stored energy mechanism (synchronizable) Motor Operator Max. switching rate (per hour) Command duration Closing time Charging time Break time Power consumption Inrush (A) Control Voltages 110 – 127 V AC 220 – 250 V AC 24 V DC 48 V DC 60 V DC DG Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MOLDED CASE CIRCUIT BREAKERS Operating Range 85 – 110% of rated control voltage 6-143 Molded Case Circuit Breakers Unusual Operating Conditions Reference High Ambient Temperatures Because thermal-magnetic trip breakers are temperature sensitive and calibrated for a specific ambient of 40° C (104° F) (average enclosure temperature), a higher ambient will cause the breaker to trip at lower current than its nameplate rating, in other words, causing the breaker to “derate” (see Table 1). Similarly, the current carrying capacity of a circuit conductor is based upon a certain ambient temperature, a higher ambient will reduce its current carrying capacity, causing it to “derate.” Thus, with a fluctuating temperature, a thermal-magnetic breaker will derate nearly parallel with its connected circuit conductors and maintain close circuit protection. If the application temperature exceeds 40° C (104° F) and is known, either a breaker specially calibrated for the higher ambient or one oversized according to Table 1 may be selected. In a case such as this, the circuit conductors should be oversized as well. Siemens Electronic Trip Unit Breakers are insensitive to temperature changes. However, they do include circuitry to protect the components from abnormally high temperatures. Moisture — Corrosion For atmospheres having high moisture content and / or where fungus growth is prevalent, a special preventive treatment may be required. Where the air is heavily laden with corrosive elements, breakers made with special corrosion-resistant finishes may be required. Altitude Reduced air density at altitudes greater than 6600 ft. (2000 meters) affects the ability of a molded case circuit breaker to transfer heat and interrupt faults. Therefore, circuit breakers applied at these altitudes should have interrupting, insulation and continuous currents derated as indicated in Figure 1. Table 1 — Temperature Derating Data for Thermal-Magnetic Breakers Reference Ampere Rating at 40° C (104° F) 0015 0020 0025 0030 0035 0040 0050 0060 0070 0090 0100 0125 0150 0175 0200 0225 0250 0300 0350 0400 0500 0600 0700 0800 0900 1000 1200 1400 1600 1800 2000 Ampere Rating at: 25° C 50° C (77° F) (122° F) 0017 0013 0022 0018 0028 0023 0033 0028 0039 0030 0044 0037 0055 0046 0066 0056 0077 0065 0099 0084 0110 0094 0137 0114 0165 0136 0192 0159 0220 0182 0247 0205 0275 0235 0330 0276 0385 0325 0440 0372 0550 0468 0660 0564 0770 0658 0880 0754 0990 0828 1100 0900 1320 1090 1540 1304 1760 1500 1980 1690 2200 1880 60° C (140° F) 0011 0016 0021 0026 0025 0034 0042 0052 0060 0078 0087 0100 0120 0140 0160 0180 0220 0252 0301 0340 0435 0525 0613 0704 0749 0825 1000 1148 1320 1485 1650 Siemens Breaker Frames BQ, BL, BQD, CQD, NGG, NGB, ED DG FG JG LG MG NG PG 13,000 (4,000) Altitude in Feet (Meters) MOLDED CASE CIRCUIT BREAKERS 6 Note: The information provided on this and the next page is intended for reference and recommendation only. Because several variables can act on a circuit breaker’s performance at the same time, the data below is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. 12,000 (3,675) 11,000 (3,350) 10,000 (3,000) 9,000 (2,750) 8,000 (2,400) 7,000 (2,100) 6,000 (1,800) 1.0 .95 .90 .85 Rating Correction Factor Figure 1 — Altitude Adjustment 6-144 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog .80 .75 Molded Case Circuit Breakers Unusual Operating Conditions 400 Hz Reference Systems 햲 Siemens molded case circuit breakers can be applied for overcurrent protection on 400Hz systems, commonly used to power computer installations, aircraft, military and other specialty equipment. Below are basic guidelines. Circuit Breaker Derating Required This table lists the maximum continuous current carrying capacity for Siemens breakers at 400Hz. Due to the increased resistance of the copper sections resulting from the skin effect produced by eddy currents at these frequencies, circuit breakers in many cases require derating. The thermal derating on these devices is based upon 100%, three phase application in open air in a maximum of 40° C (104° F) with 48 in. (1219 mm) of the specified cable or bus at the line and load side. Additional derating of not less than 20% will be required if the circuit breaker is to be utilized in an enclosure. Further derating may be required if the enclosure ambient temperature exceeds 40° C (104° F). Cable and Bus Sizing The cable and bus sizes to be utilized at 400Hz are not based on standard National Electric Codes tables for 60Hz application. Larger cross sections are necessary at 400Hz. All bus bars specified are based upon mounting the bars in the vertical plane to allow maximum air flow. All bus bars are spaced at a minimum of 0.25 in. (6 mm) apart. Mounting of bus bars in the horizontal plane will necessitate additional drafting. Edgewise orientation of the bus may change the maximum ratings indicated. If additional information is required for other connections of cable or bus, contact Siemens for information. Application Recommendations It is recommended that temperatures be measured on the line and load terminals or T-connectors of the center pole. These are usually the hottest terminals with a balanced load. A maximum temperature of 75° C (35° C over a maximum ambient of 40° C) would verify the particular application. Temperature profiles taken on these breakers can be correlated to ensure that the hottest points within the breaker are within the required temperature limits. Factory Configuration When required, molded case circuit breakers may be factory calibrated for 400Hz application. These breakers are specially labeled for 400Hz usage and their nameplate current rating will include the necessary derating factory. The highest “Maximum Continuous Amperes” rating at 400Hz, found in the table below approximates the highest specially calibrated 400Hz nameplate ampere rating available for a given frame size. Contact Siemens for ordering information on other breakers applied in 400Hz systems. 400Hz Breakers Siemens Breaker Type FG 햲 The information provided on this page is intended for reference and recommendation only. Because several variables can act on a circuit breaker’s performance at the same time, the data above is based less on controlled testing, than on experience and engineering Siemens Breaker Type JG JG 100% Rated LG MG MG 100% Rated NG NG 100% Rated PG PG 100% Rated Maximum Continuous Ampere Rating At 40° C (104° F) 햳 60HZ 400HZ Enclosed Open Air Open Air 햴 After Derating 250 210 168 300 240 192 350 260 208 400 300 240 250 210 210 300 240 240 350 260 260 400 300 300 400 300 240 500 375 300 600 420 336 600 430 360 700 500 400 800 560 448 600 430 430 700 500 500 800 560 560 800 560 448 900 600 480 1000 650 520 1200 780 624 900 600 600 1000 650 650 1200 780 780 1200 780 624 1400 850 680 1600 960 768 1200 780 780 1400 850 850 1600 960 960 judgment. Contact Siemens for further information on special conditions and treatment. derating may be required if the ambient temperature is greater than 40°C (104°F). 햳 Additional 75° C (167° F) Copper Cable per Pole No of Wire Pieces Size 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #2/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #3/0 2 250 kcmil 2 350 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 3 300 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 햴 Calculated after derating to compensate for the heating of the copper conductor, caused by the skin effect generated by eddy currents produced at 400/415HZ. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-145 MOLDED CASE CIRCUIT BREAKERS DG 75° C (167° F) Copper Cable per Pole No of Wire Pieces Size 1 #14 1 #12 1 #14 1 #12 1 #10 1 #10 1 #10 1 #8 1 #8 1 #8 1 #6 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #8 1 #6 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #1/0 1 #3 1 #2 1 #1 1 #1/0 1 #2/0 1 #3/0 1 #4/0 1 250 kcmil 6 NGG, EG Maximum Continuous Ampere Rating At 40° C (104° F) 햳 60HZ 400HZ Enclosed Open Air Open Air 햴 After Derating 015 015 012 020 020 016 15 15 12 20 20 16 25 25 20 30 30 24 35 35 28 40 40 32 45 43 34 50 48 38 60 57 46 70 67 54 80 76 61 90 86 69 100 95 76 110 105 84 125 119 95 50 48 38 60 57 46 70 63 50 80 72 58 90 80 64 100 90 72 110 95 75 125 105 84 150 125 100 100 90 72 110 95 75 125 105 84 150 125 100 175 140 112 200 160 128 225 180 144 250 200 160 Sentron® Molded Case Circuit Breakers Series Connected Short Circuit Ratings The term “Series Connected Short Circuit Rating” refers to the application of series circuit breakers in a combination that allows downstream breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by UL. The tables on these pages list specific main and branch breaker combinations that may be used for the short circuit interrupting ratings shown. 240V Series Ratings Type Branch Breaker Maximum Amperes Type QPPH 070 (1P) 125 (2P) 100 (3P) 225 (2P) 22,000 Main Breaker Number of Poles 1 2 3 Amperes 15–70 15–125 15–100 QE, BLE, QPF, BLF, QAF, BAF 2 15–60 QE, BLE, BE, QPF, BQF, BLF, QAF, BAF 1 15–30 QP, BQ, BL QPH, BQH, BLH QT 1, 2 15–40 QG, BG 1, 2 15–30 QP, BQ, BL 1 2 15–70 15–125 QE, BLE, BE, QPF, BQF, BLF, QAF, BAF 1 15–30 QE, BLE, BE, QPF, BLF, QAF, BAF 2 15–60 QPP 2 125–200 QT 1, 2 15–25 35–70 2 15–25 35–125 1 2 15–30 15–60 6 200 (2P) MOLDED CASE CIRCUIT BREAKERS QE, QPF, QAF, BAF QJH2 42,000 QJ2H 225 (2 & 3P) 225 (2 & 3P) 070 (1P) HQP, HBQ, HBL 125 (2P) 100 (3P) 65,000 HQPP 6-146 225 (2P) UL Series Connected Rating Type ED4, ED6 Branch Breaker Maximum Number Amperes Type of Poles Amperes QEH, BLEH, QE, QPHF, BLHF, BLE, QPF, BLF, 2 15–60 QAFH, BAFH, QAF, BAF 100 (1P) 125 (2 & 3P) QT 1, 2 QPPH, QPP 2 125–200 QP, BQ, BL, QPH, BQH, BLH 1 2 3 15–70 15–125 15–100 65,000 FD6-A, FXD6-A 15–30 QEH, BLEH, QE, QPHF, BLHF, BLE, QPF, BLF, 2 QAFH, BAFH, QAF, BAF 15–60 ED2 1, 2, 3 15–100 QT 1, 2 15–40 QP, BQ, BL, QPH, BQH, BLH 1 2 3 15–70 15–125 15–100 250 (2 & 3P) QPF, QPHF, BLF, BLHF, 1, 2 QAF, QAHF, BAF, BAHF (Continued) 15–40 QPHF, BQHF, BLHF, QPF, BQF, BLF, QE, 1 QEH, BLEH, BE, BLE, QAFH, BAFH, QAF, BAF 15–40 1 QP QPMH No substitutions are permitted. All combinations shown have been tested and are UL Listed. This information is provided as a reference tool only. For verification of specific combination ratings consult the UL Recognized Components Directory. 240V Series Ratings (Continued) Main Breaker UL Series Connected Rating General 15–60 QJ2H, QJ2, QJH2 2, 3 QPPH 2 125–225 60–225 QPH, BQH, BLH 1 2 3 15–70 15–125 15–100 QT 2 15–30 QP, BQ, BL 1 2 3 15–70 15–125 60–100 JXD2-A, JD6-A, JXD6-A, LD6-A, LXD6-A QJ2H, QJH2 2, 3 60–225 QPF, BQF, BLF, BG, BLG, 1 QE, BE, BLE, QAF, BAF 15–30 QPF, BLF, BG, BLG, 2 QE, BE, BLE, QAF, BAF 15–60 HJD6-A, HJXD6-A HLD6-A, HLXD6-A HMD6, HMXD6 2000 HND6, HNXD6 (2 & 3P) HPD6, HPXD6 HRD6, HRXD6 QPH 1 2 3 15–70 15–125 15–100 SJD6-A, SLD6-A, SMD6, SND6, 1600 SPD6 (2 & 3P) QPH, BQH, BLH 1 2 3 15–70 15–125 15–100 MD6, MXD6 ND6, NXD6 PD6, PXD6 RD6, RXD6 QPH, BQH, BLH 1 2 3 15–70 15–125 15–100 1 2 3 15–70 15–125 15–100 QT 1, 2 15, 20, 40 QP, BQ, BL 1 2 3 15–70 15–125 60–100 QPH, BQH, BLH 1 2 3 15–70 15–125 15–100 600 (2 & 3P) 2000 (2 & 3P) QJH2 2, 3 60–225 QP, BQ, BL, QPH, BQH, BLH 1 2 3 15–70 15–125 15–100 QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL QPF, BQF, BLF, BE, QPHF, BQHF, BLHF, 1 QEH, BLEH, QE, BLE, QAFH, BAFH, QAF, BAF 15–30 QEH, BLEH, QE, BE, QPHF, BQHF, BLHF, 1 QPF, BLF, BQF, BLE, QAFH, BAFH, QAF, BAF 15–30 QEH, BLEH, QE, QPHF, BLHF, BLE, QPF, BLF, 2 QAFH, BAFH, QAF, BAF 15–60 125 (2 & 3P) QEH, BLEH, QPHF, QE, BLHF, QPF, BLF, BLE, 2 QAFH, BAFH, QAF, BAF 15–60 HED4, HED6 100,000 QT 1, 2 15–40 ED2 1, 2, 3 15–100 QG, BG 1, 2 15–30 ED4 1 15–100 QP, BQ, BL, QPH, BQH, BLH 1 2 15–70 15–125 ED4, ED6 2, 3 15–125 QT 1, 2 15–40 ED2, ED4 1 15–100 QPF, BQF, BLF, QPHF, BQHF, BLHF, QEH, 1 BLEH, QE, BLE, BE, QAFH, BAFH, QAF, BAF 15–30 HED4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 100 (1P) Sentron® Molded Case Circuit Breakers Series Connected Short Circuit Ratings General 240V Series Ratings (Continued) UL Series Main Breaker Connected Rating Type HQPPH Branch Breaker Maximum Amperes Type QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL HQPP, QPPH, QPP 225 (2P) 1 2 15–70 15–125 2 125–225 FD6-A FXD6-A 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 300–600 ED4 1 15–100 ED4, ED6 2,3 15–125 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 200–600 Amperes 15–100 15–125 15–60 QT 1, 2 15–40 1 15–25 35–70 2 15–25 35–125 LD6-A 2, 3 LXD6-A 2, 3 450–600 3 15–100 SLD6-A 3 300–600 1 2 3 15–70 15–125 15–100 ED4 1 15–100 ED4, ED6 2, 3 15–125 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 300–600 225 (2 & 3P) QEH, BLEH, QE, BE, QPHF, BQHF, BLHF, 1 QPF, BQF, BLF, BLE, QAFH, BAFH, QAF, BAF 15–30 QEH, BLEH, QPHF, BLE, BLHF, QE, QPF, BLF, 2 QAFH, BAFH, QAF, BAF 15–60 QT 1 15–50 QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL 1 2 3 15–70 15–125 15–100 QPF, BLF, BLE, BLEH, 250 (2 & 3P) QPHF, BLHF, QEH, QE, 2 QAFH, BAFH, QAF, BAF SHLD6-A HMD6,HMXD6 600 (3P) 800 (2 & 3P) MD6, MXD6 SMD6 2,3 100,000 (Continued) SHMD6 800 (3P) 15–30 1 15–100 ED4, ED6 2, 3 15–125 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 300–600 MD6, MXD6, SMD6 2, 3 15–60 500–800 ED4 500–800 ED4 1 15–100 ED4 1 15–100 ED4, ED6 2, 3 15–125 ED4, ED6 2, 3 15–125 FD6-A, FXD6-A 2, 3 70–250 FD6-A, FXD6-A 2, 3 70–250 2, 3 200–400 QJ2, QJH2, QJ2H 2, 3 60–225 JD6-A, JXD6-A, JXD2-A, SJD6-A HQPP, QPPH, QPP 2 125–225 HND6, HNXD6, SHND6 1200 (2 & 3P) LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 300–600 QT 1, 2 15–40 ED4 1 15–100 ED4, ED6 2, 3 15–125 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 ED4 1 15–100 ED4, ED6 2, 3 15–125 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 LD6-A 2, 3 200–600 MD6, MXD6, SMD6 2, 3 LXD6-A 2, 3 450–600 ND6, NXD6, SND6 2, 3 500–1200 SLD6-A 3 300–600 PD6, PXD6, SPD6 2, 3 1200–1600 400 (2 & 3P) FD6-A, FXD6-A 600 (2 & 3P) Number of Poles 1 2, 3 HPD6, HPXD6, SHPD 1600 (3P) MD6, MXD6, SMD6 2, 3 500–800 ND6, NXD6, SND6 2, 3 500–1200 ED4 1 15–100 ED4, ED6 2, 3 15–125 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 300–600 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 500–800 6-147 MOLDED CASE CIRCUIT BREAKERS HLD6-A 600 (2 & 3P) Type ED4 ED4, ED6 6 HJD6-A, HJXD6-A, SHJD6-A HLXD6-A Branch Breaker Maximum Amperes QE, QEH, BLEH, QPHF, BLHF, QPF, BLF, BLE, 2 QAFH, BAFH, QAF, BAF QE, BE, BLE, QPHF, BQHF, BLHF, QPF, BQF, 1 BLF, QEH, BLEH, BAF, QAFH, BAFH, QAF HFD6, HFXD6 Main Breaker UL Series Connected Type Rating 15–30 QPH, BQH, BLH, HQP, HBQ, HBL 100,000 (Continued) Number of Poles Amperes QEH, BLEH, QE, BE, QPHF, BQHF, BLHF, 1 QPF, BQF, BLF, BLE, QAFH, BAFH, QAF, BAF QP, BQ, BL HQJ2H 240V Series Ratings (Continued) Sentron® Molded Case Circuit Breakers Series Connected Short Circuit Ratings General 240V Series Ratings (Continued) UL Series Main Breaker Connected Rating Type Branch Breaker Maximum Amperes Type ED4 P 1 ED4, ED6 2, 3 FD6-A, FXD6-A 2, 3 JD6-A, JXD6-A, JXD2-A, SJD6-A 100,000 HRD6, HRXD6 (Continued) 2000 (3P) 125 (2 & 3P) 6 MOLDED CASE CIRCUIT BREAKERS 250 (2 & 3P) HHJD6, HHJXD6, 600 (2 & 3P) HHLD6, HHLXD6 CJD6-A 6-148 400 (2 & 3P) Branch Breaker Maximum Amperes 15–125 Type QPH, BQH, BLH, HQP, HBQ, HBL P 2 3 70–250 ED4, ED6 2, 3 15–25 2, 3 70–250 2, 3 200–400 200–400 CLD6-A FD6-A, FXD6-A, 600 (2 & 3P) HFD6, HFXD6 Amperes 100–125 100 LD6-A 2, 3 200–600 2, 3 450–600 SLD6-A 3 300–600 LD6-A, HLD6-A 2, 3 200–600 MD6, MXD6, SMD6 2, 3 500–800 LXD6-A, HJXD6-A 2, 3 450–600 15–30 ND6, NXD6, SND6 2, 3 500–1200 QT 1, 2 PD6, PXD6, SPD6 2, 3 1200–1600 ED4, ED6 1 RD6, RXD6 2, 3 1600–2000 QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL 1 2 3 ED4, ED6, HED4, HED6 1 15–70 15–125 15–100 FD6-A, FXD6-A, HFD6, HFXD6 15–30 CMD6 JXD2-A, JD6-A, JXD6-A, HJD6-A, 800 (2 & 3P) HJXD6-A 2, 3 15 15–125 2, 3 70–250 2, 3 200–400 QEH, BLEH, QAFH, QE, QPHF, BLHF, QPF, BLE, 2 BLF, BAFH, QAF, BAF LD6-A, HLD6-A 2, 3 200–600 15–60 LXD6-A, HLXD6-A 2, 3 450–600 500–800 1 15–100 MD6, MXD6, HMD6, HMXD6 2, 3 ED4, HED4 ED4, ED6, HED4, HED6 2, 3 15–125 MD6, MXD6, HMD6, HMXD6 2, 3 500–800 15–40 ED4, ED6 1 15 15–70 15–125 15–100 ED4, ED6, HED4, HED6 2, 3 15–125 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 2, 3 200–400 QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL CFD6 UL Series Main Breaker Connected Rating Type LXD6-A QT 200,000 2, 3 Amperes 15–100 JXD2-A, JD6-A, JXD6-A, HJD6-A, HJXD6-A QPHF, BQHF, BLHF, QPF, BQF, BLF, QEH, QE, BE, BLEH, QAFH, BLE, BAFH, QAF, BAF CED6 240V Series Ratings (Continued) 1, 2 1 2 3 SCMD6 800 (3P) QPHF, BQHF, BLHF, QE, BE, BLE, 1 QPF, BQF, BLF, QEH, BLEH, QAF, BAF 15–30 QPHF, BLHF, QE, BLE, QPF, BLF, 2 QEH, BLEH, QAF, BAF LD6-A, HLD6-A 2, 3 200–600 15–60 LXD6-A, HLXD6-A 2, 3 450–600 ED2 1, 2, 3 15–100 MD6, MXD6, HMD6, HMXD6 2, 3 500–800 HED4, ED4 1 15–100 ED4, ED6, HED4, HED6 2, 3 500–1200 2, 3 15–125 ND6, NXD6, SND6, HND6, HNXD6 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 MD6, HMD6, HMXD6, MXD6, SHMD6, SMD6 2, 3 500–800 ND6, HND6, SHND6, NXD6, HNXD6, SND6 2, 3 500–1200 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 JXD2-A, JD6-A, JXD6-A, HJD6-A, HJXD6-A 2, 3 200–400 QJ2H, QJH2, QJ2 2, 3 QPPH, QPP 2 200,000 60–225 CND6-A SCND6 JXD2-A, JD6-A, JXD6-A, HJD6-A, 1200 (2 & 3P) HJXD6-A 1200 (3P) 125–225 QT 1, 2 15–40 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 QPH, BQH, BLH, HQP, HBQ, HBL 2 3 ED4, ED6 2, 3 15–125 FD6-A, FXDG-A, HFD6, HFXD6 2, 3 70–250 JXD2-A, JD6-A, JXD6-A, HJD6-A, HJXD6-A 2, 3 200–400 QT 1, 2 15–30 100–125 –100 CPD6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1600 (3P) LD6-A, HLD6-A 2, 3 200–600 LXD6-A, HLXD6-A 2, 3 450–600 MD6, MXD6, HMD6, HMXD6 2, 3 500–800 ND6, NXD6, SND6, HND6, HNXD6 2, 3 500–1200 Sentron® Molded Case Circuit Breakers Series Connected Short Circuit Ratings General 480V Series Ratings 480V Series Ratings (Continued) UL Series Main Breaker Connected Type Rating Maximum Amperes Type Number of Poles 18,000 ED4 125 (2 & 3P) BQD, CQD 1, 2, 3 15–100 25,000 ED6 125 (2 & 3P) BQD, CQD 1, 2, 3 15–100 BQD, CQD 1, 2, 3 15–100 ED4 1 15–100 ED4, ED6 2, 3 15–125 BQD, CQD 1, 2, 3 15–100 30,000 42,000 HED6 HED4 Branch Breaker 125 (2 & 3P) 125 (2 & 3P) HJD6-A, HJXD6-A, HLD6-A, 600 (2 & 3P) HLXD6-A MD6, MXD6, ND6, NXD6 SMD6, SND6, 1200 (2 & 3P) 1600 (3P) SPD6 50,000 ED4 1 15–100 ED4, ED6 2, 3 15–125 HED4 2, 3 15–50 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, SJD6-A 2, 3 200–400 HJD6-A, HJXD6-A HLD6-A, HLXD6-A 250 (2 & 3P) HMD6, HMXD6 HND6, HNXD6 햲 2, 3 70–250 JD6-A, JXD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 1 2, 3 15–100 15–30 1 15–100 BQD, CQD 햲 ED4, ED6, HHJXD6, HHJD6, HHLD6, 600 (2 & 3P) HED4 HHLXD6 HFD6, HFXD6 100,000 CMD6 800 (3P) Amperes 2, 3 70–250 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 JD6-A, HJD6-A, JXD6-A, HJXD6-A 2, 3 200–400 LD6-A, HLD6-A 2, 3 200–600 2, 3 450–600 2, 3 200–600 2, 3 450–600 500–800 3 400–600 MD6, MXD6, HMD6, HMXD6 2, 3 SLD6-A JD6-A, JXD6-A 2, 3 200–400 HFD6, HFXD6 2, 3 70–250 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 JD6-A, HJD6-A, JXD6-A, HJXD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 400–600 2, 3 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 400–600 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, SJD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 400–600 BQD, CQD 1, 2, 3 15–100 ED4, HED4 1 15–100 ED4, ED6, HED4 2, 3 15–125 HED4, ED4 1 15–100 2, 3 70–250 200–400 ED4, HED4 1 15–100 FD6-A, FXD6-A 2, 3 70–250 600 (2 & 3P) JD6-A, JXD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 FD6-A, FXD6-A 2, 3 70–250 CPD6 CJD6-A 150,000 1200 (3P) 1200 (3P) 1600 (3P) 400 (2 & 3P) LD6-A, HLD6-A 2, 3 200–600 LXD6-A, HLXD6-A 2, 3 450–600 MD6, MXD6, HMD6, HMXD6 2, 3 500–800 ND6, NXD6, HND6, HNXD6 2, 3 500–1200 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 ED4 1 15–100 HFD6, HFXD6 2, 3 70–250 JD6-A, HJD6-A, JXD6-A, HJXD6-A 2, 3 200–400 ED4 1 15–100 HFD6, HFXD6 2, 3 70–250 2, 3 200–400 JD6-A, HJD6-A, 600 (2 & 3P) JXD6-A, HJXD6-A LD6-A, HLD6-A 2, 3 200–600 LXD6-A, HLXD6-A 2, 3 450–600 1 2, 3 15–100 20–30 BQD, CQD CED6 200,000 햲 125 (2 & 3P) ED4, HED4 1 15–100 ED4, ED6, HED4 2, 3 15–125 BQD, CQD 1 2, 3 15–100 20–30 2,3 15–50 1 15–100 HED4 2, 3 15–125 FD6-A, FXD6-A, HFD6, HFXD6 2, 3 70–250 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-149 JD6-A, JXD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A 2, 3 200–400 2, 3 200–600 2, 3 450–600 MD6, MXD6, SMD6 2, 3 500–800 14–1600 (3P) FD6-A, FXD6-A CND6 CLD6-A 2, 3 1200 (2 & 3P) LD6-A SCMD, SCND6 70–250 JD6-A, JXD6-A, SJD6-A LXD6-A HPD6, HPXD6 250 (2 & 3P) FD6-A, FXD6-A LD6-A JD6-A, JXD6-A 800 (2 & 3P) CFD6 18–2000 (3P) Number of Poles LXD6-A 400 (2 & 3P) FD6-A, FXD6-A 65,000 65,000 HRD6, HRXD6 (Continued) Type 2, 3 CFD6 ED4, ED6 250 (2 & 3P) ED4, HED4 70–250 BQD & CQD breakers (2, 3P) are series rated from 15–100A for Series 7A, S2, S3, and P1 panelboard applications only. MOLDED CASE CIRCUIT BREAKERS HFD6, HFXD6 18–2000 (3P) Type Branch Breaker Maximum Amperes 6 RD6, RXD6 1600 (3P) Main Breaker LXD6-A, HLXD6-A 14–1600 (3P) FD6-A, FXD6-A PD6, PXD6 Amperes UL Series Connected Rating Sentron® Molded Case Circuit Breakers Series Connected Short Circuit Ratings General 240 Volt Fuse Series Ratings Main Breaker UL Series Connected Maximum Rating Type Amperes 65,000 J, R T 15–600 (1, 2, 3P) 15–1200 (1, 2, 3P) L 601–6000 (1, 2, 3P) T (300V) 15–200 (1, 2, 3P) 15–600 (1, 2, 3P) 6 MOLDED CASE CIRCUIT BREAKERS T QPH, BQH, BLH QPH, BQH, BLH 1, 2, 3 1, 2, 3 QPH, BQH, BLH 1, 2, 3 15–125 QP, BQ, BL 1, 2, 3 15–125 HQP, HBQ, HBL, QPH, BQH, BLH 3 15–100 T 200,000 2, 3 70–250 70–250 MD6, MXD6, HMD6, HMXD6 2, 3 500–800 ND6, NXD6, HND6, HNXD6 2, 3 500–1200 Type Number of Poles Amperes 60–400 (1, 2, 3P) ED4 1 60–100 15–400 (2, 3P) ED4 2, 3 15–100 J 15–400 (1, 2, 3P) ED4 1 15–50 T, J 70–600 (2, 3P) FD6-A, FXD6-A 2, 3 70–250 J, R 70–600 (2, 3P) HFD6, HFXD6 2, 3 70–250 JD6-A, JXD6-A HJD6-A, HJXD6-A 2, 3 200–400 LD6-A, HLD6-A 2, 3 200–600 LXD6-A, HLXD6-A 2, 3 450–600 601–6000 (2, 3P) QEH, BLEH, QE, QPF, QPHF, BLHF, BLE, BLF, 2 QAFH, BAFH, QAF, BAF 15–60 Main Breaker UL Series Maximum Connected Rating Type Amperes QT 1, 2 15–50 QPH, BQH, BLH, HQP, HBQ, HBL 1, 2 15–125 ED4, ED6, HED4 2, 3 15–125 70–600 (2, 3P) FD6-A, FXD6-A 2, 3 70–250 200–600 (2, 3P) JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 J T, J, R 200–600 (2, 3P) T 70–1200 (2, 3P) 450–600 (2, 3P) HFD6, HFXD6 2, 3 70–250 2, 3 200–400 LD6-A, HLD6-A 2, 3 200–600 LXD6-A, HLXD6-A 2, 3 450–600 15–125 HFD6, HFXD6 2, 3 70–250 2, 3 70–250 2, 3 500–800 LXD6-A 2, 3 450–600 MD6, MXD6, HMD6, HMXD6 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 ND6, NXD6, HND6, HNXD6 2, 3 500–1200 LD6-A 2, 3 200–600 BQD, CQD 1 SLD6-A 3 300–600 BQD, CQD 햲 2, 3 20–30 ED4, HED4 1 15–100 BQD, CQD 1 15–100 ED4, ED6, HED4 BQD, CQD 햲 2, 3 20–30 2, 3 15–125 2, 3 200–600 SLD6-A 3 300–600 450–600 (2, 3P) LXD6-A 2, 3 450–600 15–1200 (2, 3P) ED4, HED4 1 15–100 ED4, ED6, HED4 2, 3 70–1200 (2, 3P) FXD6-A, FD6-A 450–1200 (2, 3P) 200–1200 (2, 3P) FD6-A, FXD6-A 2, 3 70–250 JD6-A, JXD6-A, JXD2-A, SJD6-A 2, 3 200–400 LD6-A 2, 3 200–600 LXD6-A 2, 3 450–600 SLD6-A 3 300–600 SMD6 3 500–800 SND6 3 500–1200 PD6, PXD6, SPD6 3 1200–1600 1600–2000 RD6, RXD6 3 125–200 (2, 3P) QJH2, QJ2H, QJ2 2, 3 125–200 T, J 125–600 (2, 3P) QJH2, QJ2H 2, 3 125–225 125–400 (2, 3P) QJ2 2, 3 125–225 70–600 (2, 3P) HFD6, HFXD6 2, 3 70–250 T, L L R 601–1200 (2, 3P) 601–6000 (2, 3P) 15–100 (1, 2, 3P) 200,000 T, J 15–200 (1, 2, 3P) BQD & CQD breakers are series rated from 15–100A for Series 7A, S2, S3, and P1 panelboard applications only. 6-150 Branch Breaker JD6-A, JXD6-A HJD6-A, HJXD6-A LD6-A 300–600 (3P) 100,000 Number of Poles Amperes 2, 3 480 Volt Fuse Series Ratings 15–100 Type HFD6, HFXD6 15–30 50,000 Branch Breaker HFD6, HFXD6 L 70–1200 (2, 3P) QPF, BQF, BLF, QPHF, QE, BE, BLE, QEH, 1 BLEH, BLHF, BQHF, QAFH, BAFH, QAF, BAF R J, R Main Breaker UL Series Connected Maximum Rating Type Amperes 15–125 15–125 1 601–6000 (2, 3P) 200,000 햲 Type Number of Poles Amperes ED4, HED4 300–1200 (3P) L Branch Breaker 15–600 (2, 3P) J, R 100,000 240 Volt Series Ratings (Continued) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 15–100 Molded Case Circuit Breakers Unusual Operating Conditions Reference Note: The information provided on this and the next page is intended for reference and recommendation only. Because several variables can act on a circuit breaker’s performance at the same time, the data below is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. Table 1 — Temperature Derating Data for Thermal-Magnetic Breakers Ampere Rating at: 25° C 50° C (77° F) (122° F) 0017 0013 0022 0018 0028 0023 0033 0028 0039 0030 0044 0037 0055 0046 0066 0056 0077 0065 0099 0084 0110 0094 0137 0114 0165 0136 0192 0159 0220 0182 0247 0205 0275 0235 0330 0276 0385 0325 0440 0372 0550 0468 0660 0564 0770 0658 0880 0754 0990 0828 1100 0900 1320 1090 1540 1304 1760 1500 1980 1690 2200 1880 60° C (140° F) 0011 0016 0021 0026 0025 0034 0042 0052 0060 0078 0087 0100 0120 0140 0160 0180 0220 0252 0301 0340 0435 0525 0613 0704 0749 0825 1000 1148 1320 1485 1650 Siemens Breaker Frames BQ, BL, BQD, CQD, NGG, NGB, ED QJ FD JD LD MD ND PD RD Altitude in Feet (Meters) 13,000 (4,000) 12,000 (3,675) 11,000 (3,350) 10,000 (3,000) 9,000 (2,750) 8,000 (2,400) 7,000 (2,100) 6,000 (1,800) 1.0 .95 .90 .85 .80 .75 Rating Correction Factor Figure 1 — Altitude Adjustment Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-151 MOLDED CASE CIRCUIT BREAKERS Reference Ampere Rating at 40° C (104° F) 0015 0020 0025 0030 0035 0040 0050 0060 0070 0090 0100 0125 0150 0175 0200 0225 0250 0300 0350 0400 0500 0600 0700 0800 0900 1000 1200 1400 1600 1800 2000 6 High Ambient Temperatures Because thermal-magnetic trip breakers are temperature sensitive and calibrated for a specific ambient of 40° C (104° F) (average enclosure temperature), a higher ambient will cause the breaker to trip at lower current than its nameplate rating, in other words, causing the breaker to “derate” (see Table 1). Similarly, the current carrying capacity of a circuit conductor is based upon a certain ambient temperature, a higher ambient will reduce its current carrying capacity, causing it to “derate.” Thus, with a fluctuating temperature, a thermal-magnetic breaker will derate nearly parallel with its connected circuit conductors and maintain close circuit protection. If the application temperature exceeds 40° C (104° F) and is known, either a breaker specially calibrated for the higher ambient or one oversized according to Table 1 may be selected. In a case such as this, the circuit conductors should be oversized as well. Siemens Sensitrip® III and Type SB Encased Systems Breakers are insensitive to temperature changes. However, they do include circuitry to protect the components from abnormally high temperatures. Moisture — Corrosion For atmospheres having high moisture content and / or where fungus growth is prevalent, a special preventive treatment may be required. Where the air is heavily laden with corrosive elements, breakers made with special corrosion-resistant finishes may be required. Altitude Reduced air density at altitudes greater than 6600 ft. (2000 meters) affects the ability of a molded case circuit breaker to transfer heat and interrupt faults. Therefore, circuit breakers applied at these altitudes should have interrupting, insulation and continuous currents derated as indicated in Figure 1. Molded Case Circuit Breakers Unusual Operating Conditions 400 Hz Reference Systems 햲 Siemens molded case circuit breakers can be applied for overcurrent protection on 400Hz systems, commonly used to power computer installations, aircraft, military and other specialty equipment. Below are basic guidelines. Circuit Breaker Derating Required This table lists the maximum continuous current carrying capacity for Siemens breakers at 400Hz. Due to the increased resistance of the copper sections resulting from the skin effect produced by eddy currents at these frequencies, circuit breakers in many cases require derating. The thermal derating on these devices is based upon 100%, three phase application in open air in a maximum of 40° C (104° F) with 48 in. (1219 mm) of the specified cable or bus at the line and load side. Additional derating of not less than 20% will be required if the circuit breaker is to be utilized in an enclosure. Further derating may be required if the enclosure ambient temperature exceeds 40° C (104° F). Cable and Bus Sizing The cable and bus sizes to be utilized at 400Hz are not based on standard National Electric Codes tables for 60Hz application. Larger cross sections are necessary at 400Hz. All bus bars specified are based upon mounting the bars in the vertical plane to allow maximum air flow. All bus bars are spaced at a minimum of 0.25 in. (6 mm) apart. Mounting of bus bars in the horizontal plane will necessitate additional drafting. Edgewise orientation of the bus may change the maximum ratings indicated. If additional information is required for other connections of cable or bus, contact Siemens for information. Application Recommendations It is recommended that temperatures be measured on the line and load terminals or T-connectors of the center pole. These are usually the hottest terminals with a balanced load. A maximum temperature of 75° C (35° C over a maximum ambient of 40° C) would verify the particular application. Temperature profiles taken on these breakers can be correlated to ensure that the hottest points within the breaker are within the required temperature limits. Factory Configuration When required, molded case circuit breakers may be factory calibrated for 400Hz application. These breakers are specially labeled for 400Hz usage and their nameplate current rating will include the necessary derating factory. The highest “Maximum Continuous Amperes” rating at 400Hz, found in the table below approximates the highest specially calibrated 400Hz nameplate ampere rating available for a given frame size. Contact Siemens for ordering information on other breakers applied in 400Hz systems. 400Hz Breakers MOLDED CASE CIRCUIT BREAKERS 6 Siemens Breaker Type ED2, ED4, ED6, BQD, HED4, HED6, CED6 QJ2, QJH2, QJ2H, HQJ2H FD6, FXD6, HFD6, HFXD6, CFD6 JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6, CJD6 JD6, JXD6, HJD6, HJXD6 100% Rated 햲 The Maximum Continuous Ampere Rating At 40° C (104° F) 햳 60HZ 400HZ Enclosed Open Air Open Air 햴 After Derating 015 015 012 020 020 016 025 025 020 030 030 024 035 035 028 040 040 032 045 043 034 050 048 038 060 057 046 070 067 054 080 076 061 090 086 069 100 095 076 110 105 084 125 119 095 070 063 050 080 072 058 090 080 064 100 090 072 110 095 075 125 105 084 150 125 100 175 140 112 200 160 128 225 180 144 250 200 160 200 170 136 225 190 152 250 210 168 300 240 192 350 260 208 400 300 240 200 170 170 225 190 190 250 210 210 300 240 240 350 260 260 400 300 300 information provided on this page is intended for reference and recommendation only. Because several variables can act on a circuit breaker’s performance at the same time, the data above is based less on 6-152 75° C (167° F) Copper Cable per Pole No of Wire Pieces Size 1 #14 1 #12 1 #10 1 #10 1 #10 1 #8 1 #8 1 #8 1 #6 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #1/0 1 #2/0 1 #3/0 1 #4/0 1 250 kcmil 1 #3/0 1 #4/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #3/0 2 #4/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 Siemens Breaker Type LD6, LXD6, HLD6, HLXD6, HHLD6, HHLXD6, CLD6 LD6, LXD6, HLD6, HLXD6, 100% Rated MD6, MXD6, HMD6, HMXD6, CMD6 MD6, MXD6, HMD6, HMXD6, CMD6 100% Rated ND6, NXD6 HND6, HNXD6, CND6 ND6, NXD6 HND6, HNXD6, CND6 100% Rated PD6, PXD6, HPD6, HPXD6, CPD6, PD6, PXD6, HPD6, HPXD6, CPD6 100% Rated RD6, RXD6, HRD6, HRXD6 80% Rated Maximum Continuous Ampere Rating At 40° C (104° F) 햳 60HZ 400/415HZ Enclosed Open Air Open Air 햴 After Derating 0250 0210 168 0300 0240 192 0350 0260 208 0400 0300 240 0450 0340 272 0500 0375 300 0600 0420 336 0250 0210 210 0300 0240 240 0350 0260 260 0400 0300 300 0450 0340 340 0500 0375 375 0600 0420 420 0500 0400 320 0600 0430 360 0700 0500 400 0800 0560 448 0500 0400 400 0600 0430 430 0700 0500 500 0800 0560 560 0800 0560 448 0900 0600 480 1000 0650 520 1200 0780 624 0900 0600 600 1000 0650 650 1200 0780 780 1200 0780 624 1400 0850 680 1600 0960 768 1200 0780 780 1400 0850 850 1600 0960 960 1600 0960 768 1800 1080 864 2000 1200 960 controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. 햳 Additional derating may be required if the ambient Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 75° C (167° F) Copper Cable per Pole No of Wire Pieces Size 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #4/0 2 250 kcmil 2 350 kcmil 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #4/0 2 250 kcmil 2 350 kcmil 2 250 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 2 250 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 3 300 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 5 500 kcmil 5 500 kcmil 6 500 kcmil temperature is greater than 40°C (104°F). after derating to compensate for the heating of the copper conductor, caused by the skin effect generated by eddy currents produced at 400/415HZ. 햴 Calculated Molded Case Circuit Breakers IEC 947-2® AC Interrupting Ratings, 50/60 HZ KA 70-250 FD 250-400 JD 400-600 LD 600-800 LMD 600-800 MD 800-1200 ND 1200-1600 PD 1600-2000 RD Breaker Type ED6 FXD6 FD6 HFD6 HFXD6 HHFD6 HHFXD6 JXD6(A) JD6(A) HJD6(A) HJXD6(A) HHJD6 HHJXD6 CJD6 SJD6(A)햳 SHJD6(A)햳 SCJD6 LXD6(A) LD6(A) HLD6(A) HLXD6(A) HHLD6(A) HHLXD6 CLD6 SLD6(A) 햳 SHLD6(A) 햳 SCLD6 햳 LMXD6 LMD6 HLMXD6 HLMD6 MXD6 MD6 HMXD6 HMD6 CMD6 SMD6햳 SHMD6햳 SCMD6햳 NXD6 ND6 HNXD6 HND6 CND6 SND6 SHND6 SCND6 PXD6 PD6 HPXD6 HPD6 CPD6 SPD6 SHPD6 RXD6 RD6 HRXD6 HRD6 220/240 Volts Icu 65 65 65 100 100 200 200 65 65 100 100 200 200 — 65 100 — 65 65 100 100 200 200 — 65 100 — 65 65 100 100 65 65 100 100 200 65 100 200 65 65 100 100 200 65 100 200 65 65 100 100 200 — — 65 65 100 100 380/415 Volts Ics 17 33 33 50 50 100 100 33 33 50 50 100 100 — 33 50 — 33 33 50 50 100 100 — 33 50 — 33 33 50 50 33 33 50 50 100 33 50 100 33 33 50 50 100 33 50 100 33 33 50 50 100 — — 33 33 50 50 Icu 35 35 35 65 65 100 100 40 40 65 65 100 100 — 40 65 — 40 40 65 65 100 100 — 40 65 — 40 40 65 65 40 40 65 65 100 40 65 100 40 40 65 65 100 40 65 200 40 40 65 65 100 — — 40 40 65 65 500 Volts Ics 9 18 18 33 33 50 50 20 20 33 33 50 50 — 20 33 — 20 20 33 33 50 50 — 20 33 — 20 20 33 33 20 20 33 33 50 20 33 50 20 20 33 33 50 20 33 50 10 10 17 17 25 — — 10 10 17 17 Icu 18 20 20 42 42 65 65 30 30 42 42 65 65 — 30 42 — 30 30 42 42 65 65 — 30 42 — 30 30 42 42 30 30 42 42 65 30 42 65 30 30 42 42 65 30 42 65 30 30 42 42 65 — — 30 30 42 42 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Ics 5 10 10 21 21 33 33 15 15 21 21 33 b 33 b — 15 21 — 15 15 21 21 33 b 33 b — 15 21 — 15 15 21 21 15 15 21 21 33 15 21 33 15 15 21 21 33 15 21 33 8 8 11 11 17 — — 8 8 11 11 MOLDED CASE CIRCUIT BREAKERS Breaker Frame ED 6 Ampere Rating 15-125 Reference 6-153 Molded Case Circuit Breakers Typical Specifications Reference General Specifications Molded case circuit breakers shall provide circuit overcurrent protection with inverse time and instantaneous tripping characteristics and shall be Siemens Sentron, Sensitrip or approved equal. All circuit breakers shall be listed by Underwriters’ Laboratories, Inc., conform to applicable requirements of NEMA Standard Publication No. AB1 and meet appropriate classifications of Federal Specifications W C 375B/Gen. All circuit breakers shall have a quick-make, quick-break over center toggle type mechanism and the handle mechanism shall be trip free to prevent holding contacts closed against a short circuit or sustained overload. All circuit breaker handles shall assume a position between “ON” and “OFF when tripped automatically. Multi-pole circuit breakers shall be common-trip such that an overload or short circuit on any one pole will result in all poles opening simultaneously. Arc extinction is to be accomplished by magnetic arc chutes. All ratings are to be clearly visible. When reverse feed is indicated on the drawings, in accordance with UL, circuit breakers with sealed trip units shall be supplied. MOLDED CASE CIRCUIT BREAKERS 6 Thermal Magnetic Specifications Unless otherwise noted on the drawings, all Circuit breakers 2000 Ampere and below shall have thermal-magnetic trip units, with inverse time-current characteristics. Automatic operation of these circuit breakers shall be obtained by means of thermal-magnetic tripping devices located in each pole providing inverse time delay and instantaneous circuit protection. Circuit breakers shall be ambient compensating in that, as the ambient temperature increases over 40°C, the circuit breaker automatically derates itself so as to better protect its associated conductor. Thermal magnetic breakers from 250 to 2000A frames shall have thermal interchangeable trip units, with instantaneous magnetic trip settings that are adjustable and accessible from the front of all circuit breakers on frame sizes 250 Amperes and above. Where indicated, provide circuit breakers UL listed for application at 100% of their continuous ampere rating in their intended enclosure. Motor Circuit Protectors Where indicated on the drawings and in the combination motor starter/motor control center schedule, furnish instantaneous magnetic trip only circuit breakers for motor short circuit protection. The magnetic trips shall be adjustable and accessible from the front of all circuit breakers frames. The continuous current rating shall be between 1 and 800 Amperes as indicated on the drawing. Solid State Sensing Specifications As indicated on the drawings, circuit breaker frames 400 Ampere through 3200-Ampere shall have microprocessor-based RMS sensing trip units, with the capability to measure through to the 21st harmonic. Automatic operation of all circuit breaker frames 400A and larger shall be obtained by means of solid state tripping elements providing inverse time delay and (instantaneous) and/or (short-time delay) circuit protection. Continuous current ratings shall be adjustable from 20% to 100% of the trip unit rating, without the need for a rating plug. Long-time delay and instantaneous trip shall be adjustable. The optional short-time trip function shall have adjustable pick-up settings, three fixed times, and I2t ramp. Circuit breaker frames 400A and larger, and where indicated on the drawings, shall be 100% equipment rated. Integral Ground Fault Option Main and feeder circuit breakers, as indicated on the drawings, shall be provided with integral ground fault protection. Ground fault pick-up shall be adjustable from 20% to 70% of the circuit breakers maximum continuous current rating. Ground fault time delay shall be adjustable with three 12t ramps. Metering Option When indicated on the drawings, solid state trip breakers shall be furnished with a plug-in or panel mounted metering device. This device shall simultaneously display all three phase currents, as well as average current, ground current, and phase unbalance. In addition it shall display breaker status, a max log, and a trip log. The trip log will retain and display date, time and type of trip (overload, short circuit or ground fault) for the most recent 5 trip events. Current Limiting Specifications The interrupting rating of the circuit breakers shall be as indicated in the specifications, and shown on the drawing or single line diagram. The interrupting rating of the circuit breakers shall be at least equal to the available short circuit current at the line terminals of the circuit breaker and correspond to the UL listed integrated short circuit current rating specified. Internal Accessories Provide shunt trips, bell alarms, and auxiliary switches as shown on the contract drawings. Gold plated auxiliary switches shall be supplied for PLC connection. Internal accessories for all breakers shall be UL listed for field installation and modification. Where indicated on the drawings, Siemens current limiting circuit breakers are to be furnished. Current limiting circuit breakers shall limit the let-through I2t to a value less than the I2t of one-half cycle wave of the symmetrical prospective current without any fusible elements when operating within its current range. Series Connected Combination Specifications Where protective devices are applied in series combination, such that the prospective available fault current exceeds the interrupting rating (AIR) of the downstream protective devices, such combinations shall be UL recognized combinations. All electrical equipment using these UL recognized circuit breaker combinations shall be clearly marked in accordance with NEC Section 240-83(c). Connection Accessories Unless otherwise noted, Mechanical lugs shall be provided with all Molded Case Breakers. Where indicated on the drawings, compression lugs shall be provided on 1200 Ampere frame and below circuit breakers. All compression lugs shall be supplied by the Circuit Breaker Manufacturer. Where indicated on the drawings, UL listed plug-in or rear connectors shall be supplied. 6-154 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Molded Case Circuit Breakers Superseded Breakers General Sentron Series Note Superseded Note Superseded CED62B015-CED62B125 CED62S100A CED63A001-CED63A125 CED63B015-CED63B125 CED63S100A HHED62B015-HHED62B125 HHED63B015-HHED63B125 햲 CLE62B015-CLE62B100 CLE62S100 CLE63A001-CLE63A125 CLE63B015-CLE63B100 CLE63S100 HED62B015-HED62B125 HED63B015-HED63B125 햴 CE2B015-CE2B100 CE2S100 CFD62A150, CFD62L150, CFD62A250 CFD62B070-CFD62B250 CFD62S250A CFD63A150, CFD63L150, CFD63A250 CFD63B070-CFD63B250 CFD63S250A 햲 CJD62B200-CJD62B400 CJD62H400, CJD62L400 CJD62S400A CJD63B200-CJD63B400 CJD63H400, CJD63L400 CJD63S400A 햲 CPD63B120-CPD63B160 햶 CP3B120-CP3B160 ED21B015-ED21B100 ED22B015-ED22B100 ED22S100A ED23B015-ED23B100 ED23S100A 햲 ED41B015-ED41B100 ED42B015-ED42B125 ED42S100A ED43B015-ED43B125 ED43S100A 햲 ED61B015-ED61B100 ED62B015-ED62B125 ED62S100A ED63A001-ED63A125 ED63B015-ED63B125 ED63S100A HHED62B015-HHED62B125 HHED63B015-HHED63B125 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햴 CE3B015-CEB100 CE3S100 햴 CJ2B125-CJ2B250 햴 CJ3B125-CJ3B250 햵 CJ2B300-CJ2B400 햵 CJ2S400 CJ3B300-CJ3B400 햵 햵 CJ3S400 E21B015-E21B100 E22B015-E22B100 E22S100A E23B015-E23B100 E23S100A 햳 EE1B015-EE1B100 EE2B015-EE2B100 EE2S100 EE3B015-EE3B100 EE3S100 E41B015-E41B100 E42B015-E42B100 E42S100 E43B015-E43B100 E43S100 햳 E61B015-E61B100 E62B015-E62B100 E62S100A E63A001-E63A125 E63B015-E63B100 E63S100A HED62B015-HED62B125 HED63B015-HED63B125 햳 햳 햳 햳 햳 햳 햳 햳 햳 햳 햳 햳 햳 햳 EH1B015-EH1B100 EH2B015-ED2B125 EH2S100 EH3B015-EH3B100 EH3S100 EF1B015-EF1B020 EF2B015-EF2B100 EF2S100 EF3A003, EF3J050, EF3L050-EF3A100, EF3H1 EF3B015-EF3B100 EF3S100 FD62B070-FD62B250 FD63B070-FD63B250 햷 햲 FXD62A150, FXD62L150, FXD62A250 FXD62B070-FXD62B250 햷 FXD62S250A FXD63A150, FXD63L150, FXD63A250 FXD63B070-FXD63B250 햷 FXD63S250A 햲 HED41B015-HED41B100 HED42B015-HED42B125 HED43B015-HED43B125 햲 HED61B015-HED61B100 HED62B015-HED62B125 HED63B015-HED63B125 햲 HFD62B070-HFD62B250 HFD63B070-HFD63B250 햲 HHED62B015-HHED62B125 HHED63B015-HHED63B125 햲 HJD63B200-HJD63B400 햲 HJ63B200-HJ63B400 햳 HJ3B125-HJ3B400 HLD63B250-HLD63B600 햲 HL63B450-HL63B600 햳 HL3B450-HL3B600 HMD63B500-HMD63B800 햳 HN3B500-HN3B800 HND63B100-HND63B120 햳 HK3B100-HK3B120 HPD63B120-HPD63B160 햳 HP3B120-HP3B160 HRD63B160-HRD63B200 햳 HR3B160-HR3B200 햲 Mechanically 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 and electrically interchangeable. interchangeable only, refer to sales office for further details. 햴 Electrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 200 kA at 480V AC 100 kA at 600V AC 햳 Electrically MOLDED CASE CIRCUIT BREAKERS 햲 CLJ62B100-CLJ62B400 CLJ62L400, CLJ62H400 CLJ62S400 CLJ63B200-CLJ63B400 CLJ63L400, CLJ63H400 CLJ63S400 햴 F62B070, F62B250 F63B070-F63B250 FJ62A150, FJ62L150-FJ62A250 FJ62B070-FJ62B250 FJ62S250 FJ63A150, FJ63L150-FJ63A250 FJ63B070-FJ63B250 FJ63S250 햳 햳 햳 햳 햳 FJ2B070-FJ2B225 FJ2S225 FJ3A225 FJ3B070-FJ3B225 FJ3S225 HE41B015-HE41B100 HE42B015-HE42B100 HE43B015-HE43B100 HE61B015-HE61B100 HE62B015-HE62B110 HE63B015-HE63B100 햳 햳 HE2B015-HE2B100 HE3B015-HE3B100 HF62B070-HF62B250 HF63B070-HF63B250 HED62B015-HED62B125 HED63B015-HED63B125 햵 Electrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 150 kA at 480V AC 100 kA at 600V AC 햶 Refer to local sales office for replacement information. 햷 Effective 1994 — The FD6 and FXD6 types have been replaced by FD6-A and FXD6-A type thermal / magnetic circuit breakers — mechanically and electrically interchangeable with the exception that FXD6-A and FD6-A have 22kA at 600V AC ratings versus 18kA at 600V AC for types FXD6 and FD6. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6 햷 햲 CLF62A150, CLF62A250 CLF62B070-CLF62B240 CLF62S250 CLF63A150, CLF63A250 CLF63B070-CLF63B250 CLF63S250 햴 6-155 Molded Case Circuit Breakers MOLDED CASE CIRCUIT BREAKERS 6 Superseded Breakers General Sentron Series Note Superseded Note Superseded JD62B200-JD62B400 JD63B200-JD63B400 햲 JLB200-JL62B400 JL63B200-JL63B400 햳 JL2B070-JL2B400 JL3B0L0-JL3B400 JXD22B200-JXD22B400 JXD22S400A JXD23B200-JXD23B400 JXD23S400A 햲 JD22B200-JD22B400 JD22S400 JD23B200-JD23B400 JD23S400 햳 JXD62B200-JXD62B400 JXD62H400, JXD62L400 JXD62S400A JXD63B200-JXD63B400 JXD63H400, JXD63L400 JXD63S400A 햲 JJ62B200-JJ62B400 JL62L400, JL62H400 JJ62S400A JJ63B200-JJ63B400 JL63A400, JL63H400, JL63L400 JJ63S400A 햳 LD62B250-LD62B500 LD62B250-LD63B600 햲 LL63B250-LL62B600 LL63B250-LL63B600 햳 LXD62B450-LXD62B600 LXD62J600, LXD62L600 LXD62S600A LXD63B450-LXD63B600 LXD64H600, LXD63L600 LXD63S600A 햲 MD62B500-MD62B800 MD63B500-MD63B800 햳 MXD62A800, MXD62H800, MXD62L800 MXD62S800A MXD63A800, MXD63H800, MXD63L800 MXD63S800A 햳 ND63B100-ND63B900 NXD63S120A 햳 PD63B120-PD63B160 PXD63S160A 햳 RD63B160-RD63B200 햳 HR3B160-HR3B200 QJ22B060-QJ22B225 QJ22B060H-QJ22B225H QJ22S225 QJ23B060-QJ23B225 QJ23B060H-QJ23B225H 햲 QJ2B125-QJ2B225 햲 QJS225 QJ3B125-QJ3B225 QJH22B060-QJH22B225 QJH23B060-QJH23B225 QJH23S225 햲 RD63B160-RD63B200 RXD63S200A 햳 SHJD69200-SHJD69400 SHJD69200G-SHJD69400G SHJD69200NGT-SHJD69400NGT SHJD69200NT-SHJD69400NT 햲 SHLD69300-SHLD69600 SHLD69300G-SHLD69600G SHLD69300NGT-SHLD69600NG SHLD69300NT-SHLD69600NT 햲 SHND69100A-SHND69120A SHND69100AG-SHND69120AG 햲 SHPD69120-SHPD69160 SHPD69120G-SHPD69160G 햳 햲 Mechanically 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햳 햲 햲 햲 햲 햳 햳 햳 햳 햳 햳 햲 햲 햲 햳 햲 햲 햲 햲 햲 햲 햲 햳 and electrically interchangeable. interchangeable only, refer to sales office for further details. 햳 Electrically 6-156 LJ62B450-LJ62B600 LL2H600, LL2U600, LL2X600 LJ62S600 LJ63B450-LJ63B600 LL63H600, LL63L600 LJ63S600A 햳 햳 햳 햳 햳 햳 햳 햳 햳 햳 JD2B250-JD2B400 JD2S400 JD3B250-JD3B400 JD3S400 JJ2B250-JJ2B400 JL2L400-JL2H400 JJ3B200-JJ3B400 JL3H400, JL3L400, JL3A225 LL2B450-LL2B600 LL3B450-LL3B600 LL3A450, LL3H600 LL3S600 KM2B500-KM2B800 KM3B500-KM3B800 KM2A800, KM2H800, KM2L800 KM2S800 KM3A600, KM3H800, KM3L800 KM3S800 KP3B100-KP3B900 KP3S120 HP3B120-HP3B160 HP3S160 QJ2H125-QJ2B225 QJ3H125-QJ3H225 QJ3S225 HR3B160-HR3B200 HR3S200 SHJ63B200-SHJ63B400G SHJ63B200G-SHJ63B400G SHJ63N200G-SHJ63N400G SHJ63N200-SHJ63N400 SHL63B300-SHL63B600 SHL63B300G-SHL63B600G SHL63N300G-SHL63N600G SHL63N300-SHL63N600 SHND69100-SHND69800 SHND69100G-SHND69800G 햳 햳 SHKF3B100-SHKF3B800 SHKF3B100G-SHKF3B800G SHPF3B120-SHPF3B160 SHPF3B120G-SHPF3B160G 햴 Electrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 200 kA at 480V AC 100 kA at 600V AC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햵 Electrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 150 kA at 480V AC 100 kA at 600V AC 햶 Refer to local sales office for replacement information. Molded Case Circuit Breakers Superseded Breakers General Sentron Series Note Superseded Note Superseded SHND69100NGT-SHND69800NGT SHND69100NT-SHND69800NT 햲 SHKF3N100G-SHKF3N800G SHKF3N100-SHKF3N800 햳 SHK3N100G-SHK3N600G SHK3N100-SHK3N600 SHPF3B120-SHPF3B160 SHPF3B120G-SHPF3B160G SHPF3N120-SHPF3N160 SHPF3N120G-SHPF3N160G 햳 SJD69200-SJ369400 SJD69200G-SJD69400G SJD69200NGT-SJD69400NGT SJD69200NT-SJD69400NT 햲 SLD69300-SLD69600 SLD69300G-SLD69600G SLD69300NGT-SLD69600NGT SLD69300NT-SLD69600NT 햲 SMD69600A-SMD69800A SMD69600AG-SMD69800AG SMD69600ANGT-SMD69800ANGT SMD69600ANT-SMD69800ANT 햲 SND69800A-SND69120A SND69800AG-SND69120AG SND69800ANGT-SND69120ANGT SND69800ANT-SND69120ANT 햲 SPD69120-SPD69160 SPD69120G-SPD69160G SPD69120NGT-SPD69160NGT SPD69120NT-SPD69160NT 햳 햳 햳 햳 햳 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햳 햳 햳 SJL63B200-SJL63B400 SJL63B200G-SJL63B400G SJL63N200G-SJL63N400G SJL63N200-SJL63N400 SLL63B300-SLL63B600 SLL63B300G-SLL63B600G SLL63N300G-SLL63N600G SLL63N300-SLL63N600 SMD69600-SMD69800 SMD69600G-SMD69800G SMD69600NGT-SMD69800NGT SMD69600NT-SMD69800NT 햳 SND69100-SND69800 SND69100G-SND69800G SND69100NGT-SND69800NGT SND69100NT-SND69800NT 햳 — — 햵 BQCC1B015-BQC1B030 — — — 햵 CC1B015-CC1B030 CC2B015-CC2B030 CC3B015-CC3B030 — — 햵 — — — — — — 햵 — — — — — — 햴 햵 햵 햴 햴 햳 햳 햳 햳 SKPF3B100-SKPF3B600 SKPF3B100G-SKPF3B600G SKPF3N100G-SKPF3N600G SKPF3N100-SKPF3N600 EF2A003, EF2H050, EF2L050, EF2A100, EF2H150, EF2L150 EH1B015-EH1B100 EH2B015-EH2B100 EH3B015-EH3B100 HE2A003, HE2H050, HE2L050-HE2A100 HE3A003, HE3H050, HE3L050-HE3A100 HE3B015-HE3B100 MOLDED CASE CIRCUIT BREAKERS and electrically interchangeable. interchangeable only, refer to sales office for further details. 햴 These units are for replacement purposes only. Consult sales office for availability. 햳 Electrically 햵 햳 SKMF3B600-SKMF3B800 SKMF3B600G-SKMF3B800G SKMF3N600G-SKMF3N800G SKMF3N600-SKMF3N800 6 햲 Mechanically 햵 햳 SHPF3B120-SHPF3B160 SHPF3B120G-SHPF3B160G SHPF3N120-SHPF3N160G SHPF3N120G-SHPF3N160G — — — 햵 햳 SHP3B120-SHP3B800 SHP3B120G-SHP3B800G SHP3N120-SHP3N800 SHP3N120G-SHP3N800G 햵 These units are no longer manufactured, and no replacement is available. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-157 MOLDED CASE CIRCUIT BREAKERS 6 Notes 6-158 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7SPEEDFAX TM 2007-2008 Transformers Contents Features and Technical Information 7-2 Transformer—Dry Type Distribution 7-3 – 7-4 Catalog Coding System 7-5 Single Phase—Distribution Dry Type 7-6 – 7-7 Three Phase—Distribution Dry Type 7-8 – 7-11 Filtered Isolation and Motor Drive 7-12 Sentron Power Centers 7-13 NEMA TP1 – Energy Efficient & Super Energy Efficient Transformers 7-14 Harmonic Mitigation Transformers Reduced Size Transformers 7-15 – 7-16 7-17 Warehouse Stock Type QST [Standard Units] 7-18 Buck-Boost Transformers Type Q Buck-Boost Transformers and Accessories Buck-Boost Application, Selection Tables Single Phase, Three Phase Buck-Boost Connection Diagrams 7-19 7-20 – 7-23 7-24 7 TRANSFORMERS Residential Commercial Industrial Distribution Dry Type Transformers 600 Volts Class — Single and Three Phase Selection 600 Volts Class Single Phase 0.25–167 KVA Three Phase 3–1000 KVA Features ▪ Standard units are UL listed and are designed in accordance with ANSI, NEMA (ST20) and IEEE standards TRANSFORMERS 7 Encapsulated ▪ UL listed designs (UL 506) ▪ Totally enclosed, non-ventilated, heavy gauge steel enclosure ▪ Core and coil completely embedded within a resin compound for quiet, low temperature operation ▪ Encapsulation seals out moisture and air ▪ UL listed indoor/outdoor enclosure features integral wall mounting brackets ▪ Rugged design resists weather, dust, and corrosion ▪ Efficient, compact, lightweight, easy to install ▪ Flexible wiring leads that terminate within the bottom wiring compartment ▪ Large wiring compartment on the bottom with convenient knockouts ▪ High quality non-aging electrical grade core steel ▪ Precision wound coils Ventilated ▪ UL listed designs (UL 1561) ▪ Designed for indoor NEMA 2 installations. NEMA 3R enclosures suitable for outdoor locations available as an option ▪ Core and coils are designed with UL listed high-temperature materials rated for 220°C; standard units feature 150°C winding temperature rise ▪ Optional low temperature rise of 115° C or 80° C winding temperature rise for increased efficiency and additional overload capability ▪ Rugged sheet steel enclosure per UL1561, UL506 standards with removable panels for access to the internal wiring area ▪ Neoprene noise dampening pads isolate the core and coil from the enclosure ▪ Optional drip shields/weathershield and wall brackets available ▪ High quality, non-aging electrical grade core steel ▪ Precision wound coils 25KVA 277 -120/240 is 115°C rise. 25KVA 480 x 240 -120/240 is 150°C rise. Average sound level applies to 150°C rise K-1 transformers. Average dB levels for low temperature and other K-Factor ratings available upon request. NEMA Class for 80°C rise = B, 115°C rise = F, 150°C = H. Insulation class per UL 1446 180° = (H), 220° = (R) 7-2 Encapsulated Transformer Ventilated Transformer Single Phase Transformer Ampere Ratings Single Phase Full Load Amperes (FLC) KVA 120V .25 .50 .75 1 1.5 2 3 5 7.5 10 15 25 37.5 50 75 100 167 208V 240V 277V 480V 600V 2.0 4.2 6.3 8.3 12.5 1.2 2.4 3.6 4.8 7.2 1.0 2.1 3.1 4.2 6.2 0.9 1.8 2.7 3.6 5.4 0.5 1.0 1.6 2.1 3.1 0.4 0.8 1.3 1.7 2.5 16.7 25 41 62 83 9.6 14.4 24 36 48 8.3 12.5 20.8 31 41 7.2 10.8 18.0 27 36 4.2 6.2 10.4 15.6 20.8 3.3 5 8.3 12.5 16.7 125 206 312 416 625 72 120 180 240 340 62 104 156 208 312 54 90 135 180 270 31 52 76 104 156 25 41 62 83 125 833 1391 480 803 416 695 361 603 208 347 166 278 Three Phase Transformer Ampere Ratings Three Phase Full Load Amperes (FLC) KVA 208V 3 6 9 15 30 240V 8.3 16.6 25 41.7 83.4 45 75 112.5 150 225 300 500 750 1000 480V 7.2 14.4 21.6 36.1 72.3 124 208 312 416 108 180 270 360 624 832 1387 2084 2779 541 721 1202 1806 2408 600V 3.6 7.2 10.8 18.0 36.1 2.9 5.8 8.6 14.4 28.9 54.2 90 135 180 43.4 72 108 144 270 360 601 903 1204 216 288 481 723 963 Insulation Class and Temperature Rise KVA Insulation 1-Phase 0.25–25 15–167 3-Phase NEMA Class Temperature Class Temperature Rise 3–15 F 180° C 115° C 15–1000 H 220° C 150° C Sound Level in Decibels — 600V Class KVA 0–9 10–50 51–150 151–300 NEMA Average dB 40 45 50 55 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog KVA NEMA Average dB 301–500 501–700 701–1000 60 62 64 Transformers Dry Type Distribution 600 Volt Class Siemens dry type distribution transformers are rated 600 volt class and are available in a wide variety of ratings to provide versatile electrical distribution for general purpose, lighting and power loads in commercial and industrial applications. Ratings are available from 0.25 through 167 kVA single phase, and 3 through 1000 kVA 3-phase. A variety of primary and secondary voltage ratings are available to match the load requirements to the distribution system. All units meet applicable ANSI and NEMA standards. Standard designs are UL Listed. Dry type transformers are air cooled by natural convection. They require no special vaults for installation, and can be installed in locations convenient to the load being served. Encapsulated designs are provided for ratings from 0.25 kVA through 15 kVA, 1-phase, and from 3 kVA through 15 kVA 3-phase. These designs feature indoor/outdoor enclosures with integral wall mounting brackets, and 115°C rise, 180°C insulation system. Options 쐍 Special K-Factor ratings 쐍 Special voltage ratings 쐍 NEMA 3R Enclosure 쐍 80° or 115°C temperature rise 쐍 Low noise designs Ventilated Transformer A wide variety of designs and optional accessories are available including weather shields for outdoor NEMA 3R protection. 쐍 Copper windings 쐍 Drip shields 쐍 Wall mounting brackets (15–50 kVA) Ventilated Features 쐍 UL Listed Designs 쐍 Designed for Indoor Installation 쐍 Core and Coils are Designed with UL Listed High-Temperature Materials — rated for 220°C; standard units feature 150°C winding temperature rise 쐍 Rugged Sheet Steel Enclosure per ULI561, UL506 standards with Removable Panels for Access to Internal Wiring Area 쐍 Neoprene Noise Dampening Pads Isolate the Core and Coil from the Enclosure 쐍 High Quality, Non-Aging Electrical Grade Core Steel 쐍 Precision Wound Coils Encapsulated Features 쐍 UL Listed Designs 쐍 Totally Enclosed, Non-Ventilated 쐍 Heavy Gauge Steel Enclosure 쐍 Core and Coil Completely Embedded Within a Resin Compound — quiet, low temperature operation 쐍 Encapsulation — seals out moisture and air 쐍 UL Listed Indoor/Outdoor Enclosure — features integral wall mounting brackets 쐍 Rugged Design Resists Weather, Dust, and Corrosion 쐍 Efficient, Compact, Lightweight — easy to install 쐍 Flexible Wiring Leads Terminate Within Bottom Wiring Compartment 쐍 Large Wiring Compartment on Bottom with Convenient Knockouts 쐍 High Quality Non-Aging Electrical Grade Core Steel 쐍 Precision Wound Coils Options 쐍 Copper windings 쐍 Electrostatic shield (3 kVA and larger) Options 쐍 Low temperature rise of 115°C or 80°C winding temperature rise for increased efficiency and additional overload capability 쐍 Outdoor enclosures 쐍 Totally enclosed non-ventilated designs 쐍 Copper windings 쐍 Electrostatic shield 쐍 Low noise designs 쐍 K-factor rated designs 쐍 Drip shields and wall brackets available Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-3 TRANSFORMERS K-Factor Features 쐍 Designed to ANSI and NEMA Standards 쐍 UL K-Factor Listed per UL 1561 쐍 K-Factor Rating Designed to IEEE c57.110 쐍 Aluminum Wound Coils 쐍 Core, Conductors designed for Harmonics and Eddy Currents 150°C Rise, 220°C Insulation 쐍 Electrostatic Shield to Attenuate Line Transients 쐍 200% Neutral Bar (2X Phase current) 쐍 NEMA 1 Enclosure Encapsulated Transformer Ventilated designs are provided for ratings from 25 kVA through 167 kVA 1- phase, and from 15 kVA through 1000 kVA 3phase. These feature indoor enclosures, 150°C rise, and 220°C insulation system. 7 K-Factor Rated for Non-Linear Loads Siemens offers transformer designs which meet K-Factor ratings. K-Factor is a ratio between the additional losses due to harmonics and the eddy losses at 60Hz. It is used to specify transformers for non-linear loads. Note that K-Factor transformers do not eliminate harmonic distortion; they withstand the non-linear load condition without overheating. General Transformers Dry Type Distribution 600 Volt Class TRANSFORMERS 7 K-Factor Rated For NonLinear Loads Furnish and install K-Factor rated dry type transformers of the two winding type, self-cooled, with 60Hz ratings as indicated on the electrical plans. Unless specified otherwise, provide standard NEMA taps, standard impedance, and standard sound levels. Transformers shall be Siemens or approved equal. Transformers shall be designed, manufactured, and tested in accordance with ANSI, NEMA and IEEE Standards and shall be UL Listed. The self-coded kVA rating shall be suitable for 30°C average, 40°C maximum ambient temperature. Non-Linear rated transformers shall be suitable for nonsinusoidal loads and harmonic distortion as indicated in IEEE C57.110, and shall be designed with the following K-Factor rating (choose one): K4 for 50% Non-Linear load K13 for 100% Non-Linear load K20 for 150% Non-Linear load K30 for 200% Non-Linear load Non-Linear rated transformers shall be UL Listed and shall bear the UL marking on the nameplate along with the specified K-Factor rating. Non-Linear rated transformers shall include the following design features: a) Core designed to withstand voltage distortion and high frequency harmonic currents. Magnetic flux density designed to reduce eddy currents and prevent saturation or overheating of the core. b) Primary and secondary coils designed to minimize stray losses, skin effect losses, and excessive heating from harmonic currents. Coils shall not exceed the specified 7-4 winding temperature rise, the corresponding hot spot temperature rating, or the 220°C insulation rating while carrying the specified Non-Linear load. c) Neutral bus sized for 200% of rated current to withstand circulating currents and triplen harmonics. d) An Electrostatic Shield between the primary and secondary winding and grounded to a common point within the transformer enclosure. When properly grounded, the shield shall provide noise isolation and attenuate common mode and transverse mode noise transients under normal loading conditions. e) The design and materials used shall enable the transformers to comply with NEMA TP1 efficiency standards. Transformers rated 15 kVA and larger shall be a ventilated dry type with a UL Listed 220°C insulation system. Units shall be designed to operate with a rated maximum temperature rise of 150°C (Provide optional 115°C or 80°C rise when specified). Construction shall consist of aluminum windings and arranged to brace coil layers and provide maximum ventilation. (Provide optional copper windings when specified). Cores shall be constructed of non-aging electrical grade steel with high magnetic permeability and low loss characteristics. Core laminations shall be tightly assembled. The complete core and coil assembly shall be impregnated with non-hydroscopic thermo-setting varnish to provide a high dielectric, moistureresistant, and flame retardant seal. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Specifications Core and coil assemblies shall be constructed to provide short circuit with stand capability as defined by ANSI and NEMA standards. The complete assembly shall be installed on vibration dampening pads to reduce noise and securely bolted to the enclosure base. A flexible grounding conductor shall be installed between the core and coil assembly and the transformer enclosure. Enclosures shall be ventilated, heavy gauge steel construction finished with light gray paint. Front and rear covers shall be removable to provide access to the terminal compartment. Terminals shall be fully sized to carry the transformer full load current and shall be arranged to accept required UL-Listed cable connectors. Units installed outdoors shall have a UL-Listed type 3R outdoor enclosure, or shall be UL Listed with optional weathershields installed. Standard voltage ratings shall be supplied with NEMA standard taps for the high voltage windings. Unless specified otherwise, average sound levels (150°C rise) shall meet the following ANSI/ NEMA standards: 0 to 9 kVA 40 dB 10 to 50 kVA 45 dB 51 to 150 kVA 50 dB 151 to 300 kVA 55 dB 301 to 500 kVA 60 dB 501 to 700 kVA 62 dB 701 to 1000 kVA 64 dB Each transformer shall have a securely attached nameplate providing complete electrical ratings, wiring diagram, tap connections, and catalog number, as applicable. Distribution Dry Type Transformers Catalog Number Coding System for Transformers 3 F 3 Y 150 R K13 F ES C LN3 Z4 TE TEE TP1 LZ HM1 Basic Rating Information Phase Primary Voltage Secondary Voltage Taps kVA Optional Modifications Reduced Size Plus (RSP) Model K-Factor (K4, K13, K20, K30) Low Temperature Rise: 130C = (G), 115C = (F), 80C = (B) Electrostatic Shield (ES)(ES2=dual, ES3=120dB attenuation on HM1 & 2) Copper Wound (C) Low Noise (LN3 = 3dB below, LN5, etc.) Seismic Zone 4 Rated (Z4) Totally Enclosed NEMA 3R (TE) Totally Enclosed Encapsulated N-3R (TEE) Energy Efficient (NEMA -TP1) Frequency 50/60Hz Harmonic Mitigation (HM1=1 secondary/single output, HM2=2 secondaries/double output) Super Energy Efficient - Surpasses NEMA-TP1 (Available on TP1, HM1, HM2, “TP1S”, ”HM1S”, “HM2S” Phase Shift for HM1 select > (00) or (30) degree Phase Shift for HM2 select > (03) for 0 & 30 or (15) for 15 & 45 degree lagging, or (PN15) for 15 pos & 15 neg Thermal Switches (TS7=170C, TS8=180C or TS0=200C)(TS72=2 switches, TS76=6 switches @ 170C, etc.) TVSS - Filter Capacitors Secondary Side with Surge Compression Terminal Block Stainless Steel Enclosure N-3R w/DS or N4X w/SSN4X Enclosure Types NEMA 4X (SSN4X), NEMA 12 (N12), NEMA 4 (N4) Special Impedance — I4 = 4% max, I3 = 3% max etc. Fungus Proofing Core and Coil Assembly with nameplate displayed on frame bracket (may be shipped in std. enclosure) Wall Mounting Brackets (W) Vent Guard Drip Shields (weathershields) to provide NEMA-3R (DS) Note 1: If the catalog number will not completely describe the product, it will be identified as SPC-_ _ _KVA-XFMR. Note 2: “QST” suffix on catalog numbers defines units available in the Siemens warehouse distribution system. Note 3: Suffix K4TP1 or K13TP1 will indicate K-Factor rating and TP1 rating at K1 loading. Primary Phase 1-Phase 3-Phase 1 3 Secondary A B C D E F G 120/240 240 208Y/120 120/208 480Y/277 380Y/219 230Y/133 110/220 X TAPS Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y KVA KVA Catalog Code KVA Catalog Code KVA Catalog Code KVA Catalog Code 0.25 0.50 0.75 1 1.5 2 3 205 505 705 001 105 002 003 5 6 7.5 9 10 15 25 005 006 007 009 010 015 025 30 37.5 45 50 75 100 112.5 030 037 045 050 075 100 112 150 167 225 300 500 750 1000 150 167 225 300 500 750 000 Available in 3-phase 3 to 15 KVA only. are determined by transformer design and are not selectable on standard catalog units. With continuous overloads these units will be operating as 150°C rise designs. ”XES” Suffix coding for shielded isolation with filters & surge suppression. Applies to HMT designs. Taps 30 TS7 TV TB SS SSN4X I3 P CC W VG DS OPTIONAL PRODUCT OFFERINGS 1. For non-standard or non-cataloged voltages or non-cataloged primary taps refer to sales office. 2. Non-standard application, 50/60 Hz, special impedance, voltage, etc. — consult sales office. 3. Wall mounting brackets and weathershields — available at no charge on all indicated units when requested at time of initial project order. Contact sales office for feasibility of wall brackets on units with special temperature rise, low noise, or copper windings. 4. Special temperature rise: — 115° C rise, can tolerate 15% continuous overload. (Suffix Code F) — 80° C rise, can tolerate 30% continuous overload. (Suffix Code B) 5. Copper windings — Available on most designs. (Suffix Code C) 6. Low Noise Suffix code LN3 (3dB below std.) available as indicated. For LN5, etc. contact sales office with required sound level. 7. Totally Enclosed Non-Ventilated (TE) — see page 7-8. 8. Auto transformers (A) — see page 7-11. 9. Non-standard paint color — contact sales office. 10. Electrostatic shield (full width copper foil) for added noise attenuation and reduction of high frequency disturbances. (Suffix Code ES) 11. Energy Efficient (NEMA TP1), Meets TP1-1996 Efficiency. 12. Harmonic mitigating transformers—see page 7-15. 13. Transformer and panel combinations—see page 7-13. 14. Reduced Size Plus models—see page 7-17. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-5 TRANSFORMERS H 1 2 3 3 5 6 7 8 S 7 190/200/208/220x380 400/416/440 190/208/220/240x380 416/440/480 240X120 208 240 480X240 277 480 600 Export Range Export Range Selection Distribution Dry Type Transformers Single Phase KVA Catalog Number Selection List Price $ Taps Temperature Rise Insulation Mounting Type Drip Shield Required Enclosure Style Optional Modifications 115° 115° 115° 115° 115° 115° 115° 150° 150° 150° 150° 150° 150° C C C C C C C C C C C C C 180° 180° 180° 180° 180° 180° 180° 220° 220° 220° 220° 220° 220° C C C C C C C C C C C C C Wall Wall Wall Wall Wall Wall Wall Floor Floor Floor Floor Floor Floor No No No No No No No Yes Yes Yes Yes Yes Yes Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 2 2 1b, 2, 3 1b, 2, 3 1b, 2, 3 1b, 2, 3 1b, 2, 3 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 51 No No No No No No No No No No No Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated None None None 2, 1b None 2, 1b 2, 1b 2, 1b 2, 1b 2, 1b 2, 1b Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 208 Volts Primary, 120/240 Volts Secondary 1. 2. 3. 5. 7.5 010. 015. 025. 037.5 050. 075. 0100. 0167. 1B1N001 1B1N002 1B1N003 1B1N005 1B1N007 1B1N010 1B1N015 1B1Y025TP1 1B1Y037TP1 1B1Y050TP1 1B1Y075TP1 1B1Y100TP1 1B1Y167TP1 377.00 629.00 770.00 967.00 1425.00 1614.00 1859.00 5509.00 6502.00 7597.00 18495.00 20659.00 51057.00 N N N N N N N N N N N N N 240 ⴒ 480 Volts Primary, 120/240 Volts Secondary .25 .50 .75 1.0 1.5 2.0 3.0 5.0 7.5 10.0 15 1D1N205 1D1N505 1D1N705 1D1N001 1D1N105 1D1N002 1D1N003 1D1N005 1D1N007 1D1N010 1D1N015 164.00 255.00 381.00 380.00 552.00 631.00 769.00 968.00 1405.00 1603.00 1868.00 N N N N N N N N N N N 115° 115° 115° 115° 115° 115° 115° 115° 115° 115° 115° C C C C C C C C C C C 180° 180° 180° 180° 180° 180° 180° 180° 180° 180° 180° C C C C C C C C C C C Wall Wall Wall Wall Wall Wall Wall Wall Wall Wall Wall 15 25 37.5 50 1D1Y015TP1 1D1Y025TP1 1D1Y037TP1 1D1Y050TP1 3562.00 5283.00 6720.00 7737.00 Y Y Y Y 150° 150° 150° 150° C C C C 220° 220° 220° 220° C C C C Floor Floor Floor Floor 1D1Y075TP1 1D1Y100TP1 1D1Y167TP1 10254.00 21106.00 32804.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 115° 115° 115° 115° 115° 115° C C C C C C 180° 180° 180° 180° 180° 180° C C C C C C Wall Wall Wall Wall Wall Wall No No No No No No Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 1b, 1b, 1b, 1b, 1b, 1b, 2, 2, 2, 2, 2, 2, 3 3 3 3 3 31 115° 115° 115° 115° 115° 115° C C C C C C 180° 180° 180° 180° 180° 180° C C C C C C Wall Wall Wall Wall Wall Wall No No No No No No Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 1b, 1b, 1b, 1b, 1b, 1b, 2, 2, 2, 2, 2, 2, 3 3 3 3 3 31 75 100 167 & & & & Wall Wall Wall Wall TRANSFORMERS 7 277 Volts Primary, 120/240 Volts Secondary 3 5 7.5 10 15 25 1E1U003 1E1U005 1E1U007 1E1U010 1E1U015 1E1U025 755.00 978.00 1535.00 1804.00 5170.00 5311.00 U U U U U U 480 Volts Primary, 120/240 Volts Secondary 3 5 7.5 10 15 25 1F1R003 1F1R005 1F1R007 1F1R010 1F1R015 1F1R025 774.00 968.00 1415.00 1598.00 1868.00 4314.00 R R R R R R Optional Modifications Table (Contact Sales office for List Price) Optional (commonly used) Modifications Catalog Suffix Code 1a. 1b. 2. 3. 4. 5. F B ES C W DS 115° C Rise 80° C Rise Electrostatic Shield Copper Windings Wall Mounting Brackets1 Drip Shields Actual taps may vary based on volts/turn ratio. designations for units having standard features. outdoor application. Ventilated transformers requiring drip shields/weathershields are UL listed Wall For 7-6 Taps Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y for outdoor use. No charge when requested at time of initial project order. transformers are UL listed for indoor/ outdoor use. Encapsulated Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog No charge when requested at time of initial project order. marked floor and wall can be wall mounted with optional wall bracket identified with “W” suffix on catalog number. Items Discount Schedule XFMR Distribution Dry Type Transformers Single Phase KVA Selection Catalog Number List Price $ Taps Temperature Rise Insulation Mounting Type Drip Shield Required Enclosure Style Optional Modifications 180° 180° 180° 180° 180° 180° Wall Wall Wall Wall Wall Wall No No No No No No Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 1b, 1b, 1b, 1b, 1b, 1b, 600 Volts Primary, 120/240 Volts Secondary 3 5 7.5 10 15 25 1G1R003 1G1R005 1G1R007 1G1R010 1G1R015 1G1R025 25 37.5 50 75 100 167 780.00 1246.00 1759.00 1617.00 3665.00 5555.00 R R R R R R, U 115° 115° 115° 115° 115° 115° C C C C C C C C C C C C 2, 2, 2, 2, 2, 2, 3 3 3 3 3 3 1G1Y025TP1 1G1Y037TP1 1G1Y050TP1 9545.00 12171.00 14122.00 Y, U Y, U Y, U 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1G1Y075TP1 1G1Y100TP1 1G1Y167TP1 20472.00 25821.00 51057.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 2, 3, 5 2, 3, 5 2, 3, 51 See page 7-6 for footnotes & Overseas Model 190/200/208/220 x 380/400/416/440 Volts Primary, 120/240 Volts Secondary—1Ø, 50/60 Hz 1 2 3 5 7.5 10 15 1H1N001 1H1N002 1H1N003 1H1N005 1H1N007 1H1N010 1H1N015 828.00 1211.00 1570.00 1976.00 2613.00 3138.00 4030.00 N N N N N N N 115° 115° 115° 115° 115° 115° 115° 25 37.5 50 1H1N025 1H1N037 1H1N050 6532.00 7368.00 8571.00 N N N 115° C 150° C 150° C 1H1N075 1H1N100 10179.00 11550.00 N N 150° C 150° C 75 100 C C C C C C C 180° 180° 180° 180° 180° 180° 180° C C C C C C C Wall Wall Wall Wall Wall Wall Wall No No No No No No No Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 2 2 2 2 2 2 2, 3 180° C 220° C 220° C Wall Floor & Wall Floor & Wall No Yes Yes Encapsulated Ventilated Ventilated 2, 3 2, 3, 5 2, 3, 5 220° C 220° C Floor Floor Yes Yes Ventilated Ventilated 2, 3, 5 2, 3, 5 Overseas Model 190/208/220/240 x 380/416/440/480 Volts Primary, 120/240 Volts Secondary—1Ø, 50/60 Hz 1 2 3 5 7.5 10 15 1X1N001 1X1N002 1X1N003 1X1N005 1X1N007 1X1N010 1X1N015 828.00 1211.00 1570.00 1976.00 2613.00 3138.00 4030.00 N N N N N N N 115° 115° 115° 115° 115° 115° 115° C C C C C C C 25 1X1N025 6532.00 N 115° C 180° 180° 180° 180° 180° 180° 180° C C C C C C C Wall Wall Wall Wall Wall Wall Wall No No No No No No No Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 2 2 2 2 2 2 2, 3 180° C Wall No Encapsulated 2, 3 1H8N001 1H8N002 1H8N003 1H8N005 1H8N007 828.00 1211.00 1570.00 1976.00 2613.00 N N N N N 115° 115° 115° 115° 115° C C C C C 180° 180° 180° 180° 180° C C C C C Wall Wall Wall Wall Wall No No No No No Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 2 2 2 2 2 TRANSFORMERS 1 2 3 5 7.5 7 Overseas Model 190/200/208/220 x 380/400/416/440 Volts Primary, 110/220 Volts Secondary—1Ø, 50/60 Hz Notice: CE mark is included on sizes 1 through 25KVA on all overseas models. Optional Modifications Table (Contact Sales office for List Price) Optional (commonly used) Modifications Catalog Suffix Code 1a. 1b. 2. 3. 4. 5. F B ES C W DS 115° C Rise 80° C Rise Electrostatic Shield Copper Windings Wall Mounting Brackets1 Drip Shields Discount Schedule XFMR Taps Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-7 Distribution Dry Type Transformers Three Phase KVA Catalog Number Selection List Price $ Temperature Rise Taps Mounting Type Insulation Drip Shield Required Enclosure Style Optional Modifications 480 Volts Δ Primary, 240 Volts Δ Secondary With 120 Volt Tap On B Phase 15 30 45 3F1Y015TP1 3F1Y030TP1 3F1Y045TP1 4204.00 6562.00 6648.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 75 112.5 150 225 300 500 750 3F1Y075TP1 3F1Y112TP1 3F1Y150TP1 3F1Y225TP1 3F1Y300TP1 3F1Y500TP1 3F1Y750TP1 9606.00 13152.00 15852.00 22217.00 29647.00 59077.00 93911.00 Y Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 150° C C C C C C C 220° 220° 220° 220° 220° 220° 220° C C C C C C C Floor Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 2, 3, 5, 1, 2, 3, 5, 1, 2, 3, 5, 1, 2, 3, 5, 1, 2, 3, 5, 1, 2, 3, 5, 1a, 2, 3 115° 115° 115° 115° C C C C 180° 180° 180° 180° C C C C Wall Wall Wall Wall No No No No Encapsulated Encapsulated Encapsulated Encapsulated 1b, 1b, 1b, 1b, 2, 2, 2, 2, 3 3 3 3 C C C C 180° 180° 180° 180° C C C C Wall Wall Wall Wall No No No No Encapsulated Encapsulated Encapsulated Encapsulated 1b, 1b, 1b, 1b, 2, 2, 2, 2, 3 3 3 3 7 7 7 7 7 7 480 Volts Δ Primary, 240 Volts Δ Secondary 3 6 9 15 3F2R003 3F2R006 3F2R009 3F2R015 2094.00 2774.00 3457.00 5035.00 R R R R 480 Volts Δ Primary, 208Y/120 Volts Secondary 3 6 9 15 3F3R003 3F3R006 3F3R009 3F3R015 1807.00 1899.00 2735.00 2943.00 R R R R 115° 115° 115° 115° 15 30 45 3F3Y015TP1 3F3Y030TP1 3F3Y045TP1 4246.00 5467.00 6494.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 4, 5, 6, 7 75 112.5 150 225 300 500 750 1000 3F3Y075TP1 3F3Y112TP1 3F3Y150TP1 3F3Y225TP1 3F3Y300TP1 3F3Y500TP1 3F3Y750TP1 3F3S000TP1 9244.00 11607.00 15472.00 19634.00 27092.00 41465.00 92836.00 91694.00 Y Y Y Y Y Y Y J, Y, K, S 150° 150° 150° 150° 150° 150° 150° 150° 220° 220° 220° 220° 220° 220° 220° 220° Floor & Wall Floor Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 2, 3, 1, 2, 3, 1, 2, 3, 1, 2, 3, 1, 2, 3, 1, 2, 3, 1, 2, 3, None KVA Catalog Number List Price $ Taps C C C C C C C C Temperature Rise C C C C C C C C 5, 5, 5, 5, 5, 5, 7 6, 6, 6, 6, 6, 6, 7 7 7 7 7 7 Insulation Mounting Type Drip Shield Required Optional Modifications Avg. Sound Level 220° 220° 220° 220° 220° 220° Floor Floor Floor Floor Floor Floor No No No No No No None None None None None None 45dB 45dB 50dB 50dB 55dB 55dB1 No No No No No No None None None None None None 45dB 45dB 50dB 50dB 55dB 55dB1 TRANSFORMERS 7 Totally Enclosed Transformers, Indoor/Outdoor Use 480 Volts Δ Primary, 208Y/120 Volts Secondary 15 30 45 75 112.5 150 3F3Y015TE 3F3Y030TE 3F3Y045TE 3F3Y075TE 3F3Y112TE 3F3Y150TE 7260.00 10382.00 12171.00 17130.00 12626.00 15862.00 Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° C C C C C C C C C C C C 480 Volts Δ Primary, 240 Volts Δ Secondary with 120V Lighting Tap on B Phase 15 30 45 75 112.5 150 3F1Y015TE 3F1Y030TE 3F1Y045TE 3F1Y075TE 3F1Y112TE 3F1Y150TE 7260.00 10382.00 12171.00 16981.00 23718.00 30907.00 Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° Optional Modifications Table (Contact Sales office for List Price) Optional (commonly used) Modifications Catalog Suffix Code 1a. 115°C Rise 1b. 80°C Rise 2. Electrostatic Shield 3. Copper Windings 4. Wall Mounting Brackets1 5. Drip Shields 6. Low noise — 3dB below std. 7. Super Energy Efficient F B ES C W DS LN3 S1 Actual taps may vary based on volts/turn ratio. designations for units having standard features. outdoor application. Ventilated transformers requiring drip shields are UL listed for outdoor use. Encapsulated transformers are UL listed for indoor/ outdoor use (2.5% on each side of lighting tap). Reduced capacity 1-phase tap— When utilizing 1-phase Wall For 7-8 C C C C C C 220° 220° 220° 220° 220° 220° C C C C C C Floor Floor Floor Floor Floor Floor Taps Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y tap at 5%, the 3-phase load is reduced to 85% max. (5% reduction on 3 coils). 10% of rated KVA absolute maximum (evenly balanced on each side of lighting tap). When utilizing 1-phase tap at 10%, the 3-phase load is reduced to 70% max. (10% reduction on 3 coils). No charge when requested at time of initial project order. 240 volt secondary (3F2) is available in 3-phase 3 to 15KVA only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog TE units will have inrush equal to 2 sizes larger than rated KVA. marked floor and wall can be wall mounted with optional wall bracket identified with “W” suffix on catalog number. Wall mounting for 150˚C rise aluminum only. TP1S “S” features are described on page 7-14. Items Discount Schedule XFMR Distribution Dry Type Transformers Three Phase KVA Selection Catalog Number List Price $ Taps Temperature Rise Insulation Mounting Type Drip Shield Required Enclosed Type Optional Modifications 480 Volts Δ Primary, 480Y/277 Volts Secondary 15 3F5R015 4660.00 R 115° C 180° C Wall No Encapsulated 1b, 2, 3 15 30 45 3F5Y015TP1 3F5Y030TP1 3F5Y045TP1 3952.00 33766.00 8191.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 4, 5, 7 1, 2, 3, 4, 5, 7 1, 2, 3, 4, 5, 7 75 112.5 150 225 300 500 3F5Y075TP1 3F5Y112TP1 3F5Y150TP1 3F5Y225TP1 3F5Y300TP1 3F5Y500TP1 12353.00 17122.00 15157.00 30016.00 43146.00 78455.00 Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 220° 220° 220° 220° 220° 220° C C C C C C Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, 2, 2, 2, 2, 2, 2, 3, 3, 3, 3, 3, 3, 5, 5, 5, 5, 5, 5, 220° 220° 220° 220° 220° 220° 220° 220° 220° C C C C C C C C C Floor Floor Floor Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, 1, 1, 1, 3, 3, 3, 3, 3, 3, 3, 3, 3, 4, 4, 4, 5, 5, 5, 5, 5, 5, 5, 6 5, 6 5, 6 6 6 6 6 6 61 220° 220° 220° 220° 220° 220° 220° 220° 220° C C C C C C C C C Floor Floor Floor Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, 1, 1, 1, 3, 3, 3, 3, 3, 3, 3, 3, 3, 4, 4, 4, 5, 5, 5, 5, 5, 5, 5, 5, 5, 6, 6, 6, 6, 6, 6, 220° 220° 220° 220° 220° 220° 220° 220° 220° C C C C C C C C C Floor Floor Floor Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, 1, 1, 1, 3, 3, 3, 3, 3, 3, 3, 3, 3, 4, 5 4, 5 4, 5 5 5 5 5 5 51 220° 220° 220° 220° 220° 220° 220° 220° 220° C C C C C C C C C Floor Floor Floor Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, 1, 1, 1, 3, 3, 3, 3, 3, 3, 3, 3, 3, 4, 5 4, 5 4, 5 5 5 5 5 5 51 C C C C C C 7 7 7 7 7 7 3-Phase 480 Δ — 208Y/120 K-4 (50% Non-Linear Load) 15 30 45 75 112.5 150 225 300 500 3F3Y015K4TP1 3F3Y030K4TP1 3F3Y045K4TP1 3F3Y075K4TP1 3F3Y112K4TP1 3F3Y150K4TP1 3F3Y225K4TP1 3F3Y300K4TP1 3F3Y500K4TP1 5480.00 5903.00 6945.00 10012.00 13214.00 17173.00 23977.00 32603.00 81244.00 Y Y Y Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 150° 150° 150° C C C C C C C C C 3-Phase 480 Δ — 208Y/120 K-13 (100% Non-Linear Load) 15 30 45 75 112.5 150 225 300 500 3F3Y015K13TP1 3F3Y030K13TP1 3F3Y045K13TP1 3F3Y075K13TP1 3F3Y112K13TP1 3F3Y150K13TP1 3F3Y225K13TP1 3F3Y300K13TP1 3F3Y500K13TP1 6181.00 6659.00 7766.00 11103.00 14912.00 19380.00 27282.00 36776.00 96114.00 Y Y Y Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 150° 150° 150° C C C C C C C C C 6, 7 6, 7 6, 7 7 7 7 7 7 7 3-Phase 480 Δ — 208Y/120 K-20 (125% Non-Linear Load) 6659.00 9193.00 10870.00 15244.00 23304.00 25308.00 36122.00 53724.00 105122.00 Y Y Y Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 150° 150° 150° C C C C C C C C C TRANSFORMERS 3F3Y015K20TP1 3F3Y030K20TP1 3F3Y045K20TP1 3F3Y075K20TP1 3F3Y112K20TP1 3F3Y150K20TP1 3F3Y225K20TP1 3F3Y300K20TP1 3F3Y500K20TP1 7 15 30 45 75 112.5 150 225 300 500 3-Phase 480 Δ — 208Y/120 K-30 (150% Non-Linear Load) 15 30 45 75 112.5 150 225 300 500 3F3Y015K30TP1 3F3Y030K30TP1 3F3Y045K30TP1 3F3Y075K30TP1 3F3Y112K30TP1 3F3Y150K30TP1 3F3Y225K30TP1 3F3Y300K30TP1 3F3Y500K30TP1 CSO 8451.00 11749.00 CSO 28298.00 CSO CSO CSO CSO Y Y Y Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 150° 150° 150° C C C C C C C C C Optional Modifications Table (Contact Sales office for List Price) Optional (commonly used) Modifications Catalog Suffix Code 1a. 115°C Rise 1b. 80°C Rise 2. Electrostatic Shield 3. Copper Windings 4. Wall Mounting Brackets1 5. Drip Shields 6. Low noise — 3dB below std. 7. Super Energy Efficient F B ES C W DS LN3 S 1 Actual taps may vary based on volts/turn ratio. designations for units having standard features. For outdoor application. Ventilated transformers requiring drip shields are UL listed for outdoor use. Wall Discount Schedule XFMR Encapsulated Taps Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y transformers are UL listed for indoor/ outdoor use. 9 & 15kva with R taps also available in ventilated enclosures. K-Factor transformers equipped with electrostatic shield and 200% neutral as standard features. No charge when requested at time of initial project order. marked floor and wall can be wall mounted with optional wall bracket identified with “W” suffix on catalog number. TP1S features are described on page 7-14. Items Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-9 Distribution Dry Type Transformers Three Phase KVA Catalog Number Selection List Price $ Taps Temperature Rise Insulation Mounting Type Drip Shield Required Enclosure Style Optional Modifications 180° 180° 180° 180° 220° 220° 220° Wall Wall Wall Wall Floor & Wall Floor & Wall Floor & Wall No No No No Yes Yes Yes Encapsulated Encapsulated Encapsulated Encapsulated Ventilated Ventilated Ventilated 1b, 2, 3 1b, 2, 3 1b, 2, 3 1b, 2, 3 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 208 Volts Δ Primary, 208Y/120 Volts Secondary 3 6 9 15 15 30 45 3B3R003 3B3R006 3B3R009 3B3R015 3B3Y015TP1 3B3Y030TP1 3B3Y045TP1 1923.00 3055.00 4166.00 5140.00 4038.00 6953.00 21463.00 R R R R Y, T Y, T Y, T 115° 115° 115° 115° 150° 150° 150° C C C C C C C C C C C C C C 75 112.5 150 3B3Y075TP1 3B3Y112TP1 3B3Y150TP1 26602.00 33138.00 19676.00 Y, T Y, T Y, T, M 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 225 300 500 3B3S225TP1 3B3S300TP1 3B3S500TP1 32520.00 46740.00 84992.00 R, S R, S R, S 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 51 208 Volt Δ Primary, 240 Δ Secondary with 120 Volt TAP on B Phase 15 30 45 75 112.5 150 225 3B1Y015TP1 3B1Y030TP1 3B1Y045TP1 3B1Y075TP1 3B1Y112TP1 3B1Y150TP1 3B1Y225TP1 4165.00 9585.00 12455.00 19323.00 24112.00 28211.00 37520.00 Y Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 150° C C C C C C C 220° 220° 220° 220° 220° 220° 220° C C C C C C C Floor Floor Floor Floor Floor Floor Floor & & & & Wall Wall Wall Wall Yes Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, 1, 2, 2, 2, 2, 2, 2, 2, 3, 3, 3, 3, 3, 3, 3, 4, 4, 4, 4, 4, 4, 4, 5 5 5 5 5 5 5 C C C C 180° 180° 220° 220° C C C C Wall Wall Floor & Wall Floor & Wall No No Yes Yes Encapsulated Encapsulated Ventilated Ventilated 1b, 2, 3 1b, 2, 3 1, 2, 3, 4, 5 1, 2, 3, 4, 5 208 Volts Δ Primary, 480Y/277 Volts Secondary 9 15 30 45 3B5R009 3B5R015 3B5R030TP1 3B5R045TP1 4176.00 4934.00 6983.00 8201.00 R R R R 115° 115° 150° 150° 75 112.5 150 3B5R075TP1 3B5R112TP1 3B5R150TP1 11559.00 19146.00 19088.00 R R R 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 225 300 500 3B5S225TP1 3B5S300TP1 3B5S500TP1 26527.00 65844.00 95283.00 S S S 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 51 TRANSFORMERS 7 240 Volts Δ Primary, 208Y/120 Volts Secondary 15 30 45 3C3Y015TP1 3C3Y030TP1 3C3Y045TP1 7780.00 13383.00 7871.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 75 112.5 150 3C3Y075TP1 3C3Y112TP1 3C3Y150TP1 11683.00 15676.00 17465.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 225 300 500 3C3S225TP1 3C3S300TP1 3C3S500TP1 32520.00 46740.00 56332.00 S S S 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 51 240 Volts Δ Primary, 480Y/277 Volts Secondary 15 30 45 3C5Y015TP1 3C5Y030TP1 3C5Y045TP1 7780.00 9585.00 12455.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 75 112.5 150 3C5Y075TP1 3C5Y112TP1 3C5Y150TP1 17138.00 21398.00 28211.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 225 300 500 3C5S225TP1 3C5S300TP1 3C5S500TP1 45801.00 65844.00 84992.00 S S S 150° C 150° C 150° C 220° C 220° C 220° C Floor Floor Floor Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 51 Optional Modifications Table (Contact Sales office for List Price) Optional (commonly used) Modifications Catalog Suffix Code 1a. 1b. 2. 3. 4. 5. 6. F B ES C W DS1 LN31 115° C Rise 80° C Rise Electrostatic Shield Copper Windings Wall Mounting Brackets1 Drip Shields Low noise—3dB below std. Actual taps may vary based on volts/turn ratio. designations for units having standard features. outdoor application. Ventilated transformers requiring drip shields are UL listed for outdoor use. Encapsulated transformers are UL listed for indoor/ outdoor use. 9 & 15kva with R taps also available in ventilated enclosures. Taps Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y Wall For 7-10 No charge when requested at time of initial project order. Items marked floor and wall can be wall mounted with optional wall bracket identified with “W” suffix on catalog number. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Reduced capacity 1-phase tap— When utilizing 1-phase tap at 5%, the 3-phase load is reduced to 85% max. (5% reduction on 3 coils). 10% of rated KVA absolute maximum (evenly balanced on each side of lighting tap). When utilizing 1-phase tap at 10%, the 3-phase load is reduced to 70% max. (10% reduction on 3 coils). Discount Schedule XFMR Distribution Dry Type Transformers Three Phase KVA Selection Catalog Number List Price $ Taps Temperature Rise Insulation Mounting Type Drip Shield Required Enclosure Style Optional Modifications 180° 180° 180° 180° Wall Wall Wall Wall No No No No Encapsulated Encapsulated Encapsulated Encapsulated 1b, 1b, 1b, 1b, 600 Volts Δ Primary, 208Y/120 Volts Secondary 3 6 9 15 3G3R003 3G3R006 3G3R009 3G3R015 3476.00 2541.00 3137.00 4846.00 R R R R 115° 115° 115° 115° 15 30 45 75 112.5 150 225 300 500 C C C C C C C C 2, 2, 2, 2, 3G3Y015TP1 3G3Y030TP1 3G3Y045TP1 6740.00 8309.00 10797.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 3G3Y075TP1 3G3Y112TP1 3G3Y150TP1 3G3Y225TP1 3G3Y300TP1 3G3Y500TP1 14854.00 18545.00 24455.00 32520.00 46740.00 84992.00 Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° C C C C C C 220° 220° 220° 220° 220° 220° C C C C C C Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, C C C C 180° 180° 180° 180° C C C C Wall Wall Wall Wall No No No No Encapsulated Encapsulated Encapsulated Encapsulated 2 2 2 2 2, 2, 2, 2, 2, 2, 3 3 3 3 3, 3, 3, 3, 3, 3, 5 5 5 5 5 51 600 Volts Δ Primary, 480Y/277 Volts Secondary 3 6 9 15 3G5R003 3G5R006 3G5R009 3G5R015 1819.00 3009.00 4684.00 8424.00 R R R R 115° 115° 115° 115° 15 30 45 3G5Y015TP1 3G5Y030TP1 3G5Y045TP1 7780.00 9585.00 12455.00 Y Y Y 150° C 150° C 150° C 220° C 220° C 220° C Floor & Wall Floor & Wall Floor & Wall Yes Yes Yes Ventilated Ventilated Ventilated 2, 4, 5 2, 4, 5 2, 4, 5 75 112.5 150 225 300 500 3G5Y075TP1 3G5Y112TP1 3G5Y150TP1 3G5Y225TP1 3G5Y300TP1 3G5Y500TP1 17138.00 30128.00 28211.00 37520.00 52867.00 98065.00 Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 220° 220° 220° 220° 220° 220° Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated 1, 1, 1, 1, 1, 1, Mounting Type Drip Shield Required Enclosure Style Optional Modifications C C C C C C C C C C C C 2, 2, 2, 2, 2, 2, 3, 3, 3, 3, 3, 3, 5 5 5 5 5 51 Dual Purpose Auto Transformers KVA 600V Pri 480V Pri 480V Sec 380V Sec Catalog Number List Price $ Taps Temperature Rise Insulation 600 Volts Primary, 480 Volts Secondary 3Ø 60 Hz &— 480 Volts Primary 380 Volts Secondary 3Ø 50/60 Hz Alternate Rating 75 112.5 150 225 300 500 60 90 120 180 240 400 3G4R015A 3G4R030A 3G4R045A 2008.00 2549.00 3816.00 R R R 115° C 115° C 115° C 180° C 180° C 180° C Wall Wall Wall 3G4R075A 5552.00 3G4R112A 6603.00 3G4R150A 7655.00 3G4R225A 9240.00 3G4R300A 12020.00 3G4R500A 16155.00 R R R R R R 115° 150° 150° 150° 150° 150° 180° 220° 220° 220° 220° 220° Floor Floor Floor Floor Floor Floor C C C C C C Optional Modifications Table (Contact Sales office for List Price) Optional (commonly used) Modifications Catalog Suffix Code 1a. 1b. 2. 3. 4. 5. F B ES C W DS 115° C Rise 80° C Rise Electrostatic Shield Copper Windings Wall Mounting Brackets1 Drip Shields Actual taps may vary based on volts/turn ratio. designations for units having standard features. outdoor application. Ventilated transformers requiring drip shields are UL listed for outdoor use. Wall For Discount Schedule XFMR Encapsulated C C C C C C & & & & & & Wall Wall Wall Wall Wall Wall Encapsulated Encapsulated Encapsulated — — — No Yes Yes Yes Yes Yes Encapsulated Ventilated Ventilated Ventilated Ventilated Ventilated 4 4, 5 4, 5 4, 5 4, 5 51 Taps Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y transformers are UL listed for indoor/ outdoor use. charge when requested at time of initial project order. If used on unbalanced loads, these auto transformers will need to be used on a 4-wire system with the supply neutral connected to the transformer. If used on motor No No No No TRANSFORMERS 12 24 36 7 15 30 45 loads, then they may be used on a 3-wire system without a neutral or fourth wire. Review in NEC 450-4 and 450-5. marked floor and wall can be wall mounted with optional wall bracket identified with “W” suffix on catalog number. Items Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-11 Distribution Dry Type Transformers Three Phase Selection Isolation & Filtering Transformers shielding provide excellent transverse mode noise attenuation of 60 db. Additionally the common mode noise attenuation of 120 db will increase protection from line noise, spikes and surges. either 208 volt or 480 volt primary and 280Y/120 volt secondary up to 225 kVA. All units have spike/surge protection on the primary side and low pass filters on the secondary. The combination of these components and the electrostatic The Siemens “XES” models are specifically designed to protect sensitive equipment from surges, spikes and line noise. These designs are available with Shielded Isolation with Filter Capacitors and Surge Suppression (“XES” Models) KVA Catalog Number List Price $ Taps Temperature Rise Insulation Mounting Type Drip Shield Required Enclosure Style Optional Modifications 150° 150° 150° 150° 150° C C C C C 220° 220° 220° 220° 220° C C C C C Floor Floor Floor Floor Floor & & & & Wall Wall Wall Wall Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated 1, 3, 4, 5 1, 3, 4, 5 1, 3, 4, 5 1, 3, 5 1a, 3, 5 150° 150° 150° 150° 150° C C C C C 220° 220° 220° 220° 220° C C C C C Floor Floor Floor Floor Floor & & & & Wall Wall Wall Wall Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated 1, 3, 4, 5 1, 3, 4, 5 1, 3, 4, 5 1, 3, 5 1a, 3, 5 150° 150° 150° 150° 150° C C C C C 220° 220° 220° 220° 220° C C C C C Floor Floor Floor Floor Floor & & & & Wall Wall Wall Wall Yes Yes Yes Yes Yes Ventilated Ventilated Ventilated Ventilated Ventilated 1, 3, 4, 5 1, 3, 4, 5 1, 3, 4, 5 1, 3, 5 1a, 3, 5 480 Volts Δ Primary, 208Y/120 Volts Secondary 15 30 45 75 112.5 3F3Y015XESTP1 3F3Y030XESTP1 3F3Y045XESTP1 3F3Y075XESTP1 3F3Y112XESTP1 6504.00 9008.00 11000.00 16130.00 18000.00 Y Y Y Y Y 208 Volts Δ Primary, 208Y/120 Volts Secondary 15 30 45 75 112.5 3B3Y015XESTP1 3B3Y030XESTP1 3B3Y045XESTP1 3B3Y075XESTP1 3B3Y112XESTP1 6504.00 9008.00 11000.00 16130.00 18000.00 Y Y Y Y Y 240 Volts Δ Primary, 208Y/120 Volts Secondary 15 30 45 75 112.5 3C3Y015XESTP1 3C3Y030XESTP1 3C3Y045XESTP1 3C3Y075XESTP1 3C3Y112XESTP1 6504.00 9008.00 11000.00 16130.00 18000.00 Y Y Y Y Y Taps (See page 7-11) Motor Drive Isolation TRANSFORMERS 7 Three Phase 60HZ Motor Drive Isolation Transformers KVA Motor H.P. Catalog Number 7.5 11 15 20 27 34 40 51 3&5 7.5 10 15 20 25 30 40 DT DT DT DT DT DT DT DT ( ( ( ( ( ( ( ( ) ) ) ) ) ) ) ) 007 011 015 020 027 034 040 051 50 60 75 100 125 150 200 250 300 400 500 600 DT DT DT DT DT DT DT DT DT DT DT DT ( ( ( ( ( ( ( ( ( ( ( ( ) ) ) ) ) ) ) ) ) ) ) ) 063 075 093 118 145 175 220 275 330 440 550 660 63 75 93 118 145 175 220 275 330 440 550 660 DT ( ) Code 18 20 21 22 24 30 42 44 45 52 54 Actual List Price $ Standard Taps Temperature Rise Insulation Mounting Type Drip Shield Required 3045.00 5492.00 5008.00 5797.00 6902.00 7659.00 8073.00 9163.00 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN 115° 115° 150° 150° 150° 150° 150° 150° C C C C C C C C 180° 180° 220° 220° 220° 220° 220° 220° C C C C C C C C Floor Floor Floor Floor Floor Floor Floor Floor Yes Yes Yes Yes Yes Yes Yes Yes 10650.00 12130.00 12366.00 13114.00 15537.00 18626.00 23366.00 CSO CSO CSO CSO CSO 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 2–5% 6.2% FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN FCAN/BN 150° 150° 150° 150° 150° 150° 150° 150° 150° 150° 150° 150° C C C C C C C C C C C C 220° 220° 220° 220° 220° 220° 220° 220° 220° 220° 220° 220° C C C C C C C C C C C C Floor Floor Floor Floor Floor Floor Floor Floor Floor Floor Floor Floor Primary Volts 208 Delta 208 Delta 208 Delta 230 Delta 230 Delta 380 Delta 460 Delta 460 Delta 460 Delta 575 Delta 575 Delta taps may vary based on volts/turn ratio. outdoor application. Ventilated transformers requiring drip shields are UL listed for outdoor use. No charge when requested at time of initial project order. For 7-12 Secondary Volts 208Y/120 230Y/133 460Y/266 230Y/133 460Y/266 460Y/266 230Y/133 460Y/266 380Y/220 230Y/133 460Y/266 Motor Drive Isolation Optional Modifications marked floor and wall can be wall mounted with optional wall bracket identified with “W” suffix on catalog number. Refer selection and application guide for additional information on horsepower, Ampere, KVA ratings and Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Wall Wall Wall Wall Wall Wall Wall Wall Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Catalog Suffix Code 1a. 115° C Rise 1b. 080° C Rise 2. Electrostatic Shield 3. Copper Windings 4. Wall Mounting Brackets 5. Drip Shields/Weather Shields 6. Thermal Switches (Contact Sales office for List Price) Items & & & & & & & & F B ES C W DS TS applications. Standard taps varies with design volts/turn ratio. sizes 225 through 660 are available in “RSP” designs as described on page 7-17. KVA Discount Schedule XFMR Distribution Dry Type Transformers Sentron Power Centers Economical Space Saving Package Siemens Sentron Power Center is a pre-wired combination of a primary breaker disconnect, dry type shielded transformer, secondary breaker disconnect and a secondary power panel all in one convenient package. You save time, space and money by not having to individually assemble, mount and wire these components. Simply add the branch and you’re ready to go. UL-3R Enclosures All Sentron Power Center enclosures are UL-3R listed for indoor and outdoor use. Transformer Assembly Siemens totally encapsulated distribution transformers are designed for general purpose indoor/outdoor operation. Sentron Power Centers can be installed in a wide variety of atmospheric and environmental conditions. A 180°C, UL recognized insulation system is used. Selection Sentron Power Center units are electrostatically shielded to provide transient voltage protection at no extra cost. All units have 2-5% FCBN taps. Panel Assembly The power panel assembly will accommodate one-inch, 1, 2 or 3-pole, common trip, duplex secondary branch circuit breakers, Type Q and QT as well as ground fault circuit breakers. Per UL and NEC requirements, the Sentron Power Center assembly comes fully equipped with primary and secondary main circuit breakers. Branch circuit breakers can be obtained from our local distributor once you have established your branch circuit requirements. All Sentron Power Centers are UL listed for service entrance. Maximum Secondary Circuits KVA Catalog Number List Price $ 1" Wide 1/2" Wide 2" Wide 120V (1-Pole) 120V (1-Pole) 240V (2-pole) Interior Number Reference Approximate Dimensions (in inches) Height Width Depth Approximate Net Weight (lbs.) 7.63 11.00 11.00 12.38 13.50 120 160 185 240 330 7.63 12.38 13.38 13.75 255 385 535 680 480 Volts Δ Primary, 240/120 Volts Secondary — Single Phase — Sentron Power Centers 5.0 7.5 10.0 15.0 25.0 1LPC005 1LPC007 1LPC010 1LPC015 1LPC025 4310.00 5082.00 5520.00 6667.00 8412.00 8 8 8 12 20 16 16 16 24 40 4 4 4 6 10 I1224L1100CU I1224L1100CU I1224L1100CU I1224L1125CU I2440L1200CU 32.13 32.13 34.38 34.38 41.88 13.25 15.88 15.88 17.13 17.88 3LPC009 3LPC015 3LPC022 3LPC030 8404.00 12140.00 13486.00 15310.00 12 12 18 24 24 24 36 42 4 4 6 8 I1836L3200CU I1836L3200CU I2442L3200CU I3042L3200CU 33.75 35.13 38.25 43.75 22.13 22.13 30.25 33.00 TRANSFORMERS 9.0 15.0 22.5 30.0 7 480 Volts Δ Primary, 208Y/120 Volts Secondary — Three Phase — Sentron Power Centers Circuit Breaker Data for Sentron Power Centers 480 Volts Δ to 280Y/120 Volts — Three Phase 480 Volts to 240/120 Volts — Single Phase KVA 480 Volts Primary Breaker 240/120 Volts Secondary Main Maximum Rating of Secondary Breakers 5.0 7.5 10.0 15.0 25.0 ED42B025L ED42B025L ED42B035L ED42B050L ED42B090L Q225 (25A) Q240 (40A) Q250 (50A) Q270 (70A) Q2125 (125A) 20 30 40 60 100 (25A) (25A) (35A) (50A) (90A) Primary breaker has lineside lug for customer connection. Single Phase – 18,000 Amps RMS Symmetrical Interrupting Capacity. Three Phase – 18,000 Amps RMS Symmetrical Interrupting Capacity. Discount Schedule XFMR Amps Amps Amps Amps Amps Sentron KVA 480 Volts Primary Breaker 280Y/120 Volts Secondary Main Maximum Rating of Secondary Breakers 9.0 15.0 22.5 30.0 ED43B025L ED43B040L ED43B070L ED43B090L Q330 (30A) Q350 (50A) Q370 (70A) Q3100 (100A) 25 40 60 80 Power Centers are NEMA 3R for outdoor application and may be ordered with “SS” suffix for 304 stainless steel enclosure. Secondary branch breakers are not included and must be ordered separately. Primary and secondary main breakers are included and are factory installed. (25A) (40A) (70A) (90A) Amps Amps Amps Amps ED frame breakers furnished are rated 18000 AIC and are sufficient for fault current of transformer. If higher AIC rating is required by spec, the ED can be changed in the field to HED 4 (22000 AIC) or HHED6 (65000 AIC). 1LPC005 and 3LPC009 are copper wound. Available with Stainless Steel NEMA 3R enclosures by adding catalog number suffix “SS”. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-13 Transformers NEMA TP1 Energy Efficiency Standard Single Phase and Three Phase TP1–Energy Efficient Transformers Most commercial and industrial facilities require several low-voltage transformers to decrease the voltage received from the utility to the voltages used by various loads such as lighting, computers and other electrically operated equipment. Standard transformers convert approximately 95% of the electricity received into usable output voltage. Since these transformers are energized continually, even a small improvement in efficiency can provide significant energy savings. These energy efficient transformers are specifically designed to help save money on utility bills and reduce energy waste. Depending on the size of the transformer, a “NEMA TP1 compliant” transformer can save $100-300 each year at an electricity rate of $0.075 cents per kWh. A typical large commercial facility will have 6-10 low voltage transformers, and thus can save between $600 and $3,000 per year. Basic Design Characteristics The TP1 designs include the use of higher grade electrical steel and other features designed to lower flux density and reduce TRANSFORMERS 7 New Super Energy Efficient Transformers: TP1S, HM1S & HM2S TP1S transformer designs surpass the NEMA TP1 standards for efficiency. These units are designed not to exceed 115°C temperature rise above a 40°C ambient under full linear load and not to exceed 150°C rise under a non-linear load level of K13 (K20 for HMT units). Standard features of the TP1S, HM1S, HM2S units include: ▪ Higher efficiency level with Linear Load Efficiency: 25% less loss than NEMA TP-1 from 35% to 65% load @ 75°C for sizes 15-750KVA 7-14 losses especially at average 35% loading where the TP1 measurements apply. To meet TP1 the design engineer must consider both the “I square R” losses and the core or iron loses. Simple de-rating from a higher kVA will not satisfy the TP1 standards as the efficiency level is dependent on the combination of core (no-load) losses and I2R (winding) losses. The core construction employs the use of high quality non-aging electrical grade grain-oriented silicon steel with high permeability, low hysteresis and low eddy current losses. These characteristics are required to achieve the TP1 efficiency levels. Core laminations must be tightly assembled enabling magnetic flux densities to be kept well below the saturation point. The core and coil designs must be low loss type with minimum efficiencies per NEMA TP1 when operated at 35% of full load capacity. Efficiency shall be tested in accordance with NEMA TP2 (Standard test method for measuring the energy consumption of distribution transformers). The efficiency levels must meet the following minimums. ▪ TP1S units are TP1 Rated efficiency under non-linear loads with a load profile of K13 at 50% loads @ 75°C ▪ Noise levels are 3 dB lower than NEMA ST-20 ▪ Standard 200% neutral ▪ K13 rating on nameplate (K20 for HMT units) ▪ Electrostatic shield ▪ Ten year pro-rated warranty with standard liability limitations same as Sentron Harmonic Mitigation units Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Selection TP1- Energy Efficient transformers: Single kVA 15 25 37.5 50 75 100 167 250 333 Phase Efficiency 97.7% 98.0% 98.2% 98.3% 98.5% 98.6% 98.7% 98.8% 98.9% Three kVA 15 30 45 75 112.5 150 225 300 500 750 Phase Efficiency 97.0% 97.5% 97.7% 98.0% 98.2% 98.3% 98.5% 98.6% 98.7% 98.8% Transformers Sentron Harmonic Mitigating Transformers (HM1 & HM2) Description The Sentron Harmonic Mitigating Transformers (HMTs) are designed to meet the needs of modern power distribution systems that contain a large percentage of non-linear equipment that produces harmonics. Some examples of this type of equipment are computers, printers, fax machines, scanners, copiers, uninterruptible power supplies, ballast and variable frequency drives (VFD). This type of equipment generates harmonic voltages and currents because they contain AC to DC power conversion rectifiers. Harmonic voltages and currents can cause a variety of problems ranging from poor power factor, voltage distortion, capacitor resonance and motor failures to overloaded transformers and conductors. The Sentron HMTs are specially designed to operate under high non-linear load conditions and have the additional benefit of improving the overall power system reliability. Application Elimination of undesirable harmonics by using the Siemens Sentron HMTs is an effective solution to the power quality problems encountered by today’s power system professionals. By treating the harmonics at their source, using advanced technology, installation problems can be avoided and overall system reliability improved. The Sentron HMT product line provides many far Design and Construction Features The Sentron Harmonic Mitigating Transformers comply with all applicable ANSI/IEEE standards including C57.12.91, C57.96, C57.110, CSA # C22.2 No. 47 (CUL), UL506, UL1561 as well as NEMA ST-20. The design life is 25 years at 130 degree C rise, 30 years at 115C rise and 40 years for 80C rise models. Approvals and listings include UL, CSA. with CE approval available when requested. The Sentron HMTs have capability up to the load capability up to K-20, which is achieved by harmonic cancellations in the secondary and low flux density design for protection against heat in place of design enlargement protection only. Copper coil windings with full width copper foil electrostatic shield are standard and additional shield options are available for higher noise attenuation requirements. All HMTs have 130C rise with optional 115C and 80C winding rise designs available. All designs include vacuum impregnated polyester resin encapsulation of windings and NEMA 3R enclosures. A neutral sized at 200% of the ampacity of the secondary phase conductors for extra protection against triplens and unbalanced single phase loads. The Sentron HMT designs have TP1 energy efficient rating equal to that of a non K-Factor rated transformer and have the Energy Star emblem displayed. Siemens HMT designs have TP1 efficiency levels at 35% load @ ref temp. 75 degree C and also retain TP1 efficiency levels at 65% load @ reference temperature 85C. A ten-year pro-rated warranty with standard liability limitations applies to all Sentron HMTs. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-15 TRANSFORMERS Benefits Selection reaching benefits such as lower operating cost, improved operating efficiency, reduced down-time due to outages caused by nuisance tripping, and increased equipment life due to low voltage distortions. 7 One of the most effective ways to eliminate power system harmonics is to use a technique known as “phase shifting.” In this method power system harmonics are eliminated by pairing together harmonics that have 180° relative angular displacement, which causes them to cancel one another out. This can be accomplished by a variety of means: Single Output Harmonic Mitigating Transformer (0° or -30° primary-secondary angular displacement) The primary of this transformer has a delta connection and its secondary has a special double winding connection. Although there is only one secondary three phase output, the 3rd, 9th and 15th harmonic currents are prevented from circulating in the primary windings by canceling their magnetic fluxes at low impedance with the double winding secondary, reducing voltage distortions to the loads. When two transformers with this type of connection, 0° and -30° displacement, are used in parallel, the 3rd, 9th and 15th harmonic currents are canceled as previously described, and additionally the 5th and 7th harmonic currents are cancelled in the electrical supply common to both transformers due to their relative 30° phase shift. If a single harmonic mitigating transformer (0°) is used in an existing or new system utilizing standard delta-wye transformers (-30°), the 5th and 7th harmonic currents originating from the HMT transformer (0°) will attempt to cancel the 5th and 7th harmonic currents originating from the standard delta-wye transformer (-30°). This reduces the overall 5th and 7th harmonics present in the system, with the actual reduction dependent on the magnitudes of the secondary loads. Double-Output Harmonic Mitigating Transformer (0° and -30°, -15° and -45°, or +15°and -15° primary-secondary angular displacement) The primary of this transformer has a delta connection and its secondary has double-output, special double winding connections with 30° phase shift between outputs. This arrangement cancels the 3rd, 5th, 7th, 9th, and 15th harmonics at very low impedance on the secondary side. This greatly improves voltage distortion for the loads and the primary power factor. The advantage of this arrangement is that the reductions of harmonic currents are achieved with one transformer creating a 12 pulse load. If two of these transformers are used, with the primaries of each phase shifted 15° with respect to one another, then cancellation of harmonics up to the 19th are achievable creating a 24 pulse load. Transformers Sentron Harmonic Mitigating Transformers (HM1 & HM2) TRANSFORMERS 7 Catalog Number Coding: Single output (1 secondary) = HM1, Double output (2 secondaries) = HM2. Phase Shift Options: HM1 followed by > (00) or (30) degree. HM2 > (03) for 0 & 30 or (15) for 15 & 45 degree lagging, or (PN15) =15 pos & 15 neg. HMT, 480 Volt Primary 120/208 Volt Secondary (3F3) - 130C (standard), 115C and 80C Winding Rise displayed on this page. 130C (std.) Rise HMT List KVA Catalog Number Price $ 햲 15 3F3Y015GHM100 햲 15 3F3Y015GHM130 햲 15 3F3Y015GHM203 햲 15 3F3Y015GHM215 햲 15 3F3Y015GHM2PN15 햲 30 3F3Y030GHM100 햲 30 3F3Y030GHM130 햲 30 3F3Y030GHM203 햲 30 3F3Y030GHM215 햲 30 3F3Y030GHM2PN15 햲 45 3F3Y045GHM100 햲 45 3F3Y045GHM130 햲 45 3F3Y045GHM203 햲 45 3F3Y045GHM215 햲 45 3F3Y045GHM2PN15 햲 75 3F3Y075GHM100 햲 75 3F3Y075GHM130 햲 75 3F3Y075GHM203 햲 75 3F3Y075GHM215 햲 75 3F3Y075GHM2PN15 햲 112.5 3F3Y112GHM100 햲 112.5 3F3Y112GHM130 햲 112.5 3F3Y112GHM203 햲 112.5 3F3Y112GHM215 햲 112.5 3F3Y112GHM2PN15 햲 150 3F3Y150GHM100 햲 150 3F3Y150GHM130 햲 150 3F3Y150GHM203 햲 150 3F3Y150GHM215 햲 150 3F3Y150GHM2PN15 햲 225 3F3Y225GHM100 햲 225 3F3Y225GHM130 햲 225 3F3Y225GHM203 햲 225 3F3Y225GHM215 햲 225 3F3Y225GHM2PN15 햲 300 3F3Y300GHM100 햲 300 3F3Y300GHM130 햲 300 3F3Y300GHM203 햲 300 3F3Y300GHM215 햲 300 3F3Y300GHM2PN15 햲 500 3F3Y500GHM100 햲 500 3F3Y500GHM130 햲 500 3F3Y500GHM203 햲 500 3F3Y500GHM215 햲 500 3F3Y500GHM2PN15 115C Rise HMT Catalog Number 3F3Y015FHM100 3F3Y015FHM130 3F3Y015FHM203 3F3Y015FHM215 3F3Y015FHM2PN15 3F3Y030FHM100 3F3Y030FHM130 3F3Y030FHM203 3F3Y030FHM215 3F3Y030FHM2PN15 3F3Y045FHM100 3F3Y045FHM130 3F3Y045FHM203 3F3Y045FHM215 3F3Y045FHM2PN15 3F3Y075FHM100 3F3Y075FHM130 3F3Y075FHM203 3F3Y075FHM215 3F3Y075FHM2PN15 3F3Y112FHM100 3F3Y112FHM130 3F3Y112FHM203 3F3Y112FHM215 3F3Y112FHM2PN15 3F3Y150FHM100 3F3Y150FHM130 3F3Y150FHM203 3F3Y150FHM215 3F3Y150FHM2PN15 3F3Y225FHM100 3F3Y225FHM130 3F3Y225FHM203 3F3Y225FHM215 3F3Y225FHM2PN15 3F3Y300FHM100 3F3Y300FHM130 3F3Y300FHM203 3F3Y300FHM215 3F3Y300FHM2PN15 3F3Y500FHM100 3F3Y500FHM130 3F3Y500FHM203 3F3Y500FHM215 3F3Y500FHM2PN15 Optional Modifications Table for HMTs Sound Level A LN3= (3dB below NEMA standard) B LN5= (5dB below NEMA standard) Attenuation—Single shield—60dB Common Mode Std. C ES2= Double shield—80dB Common Mode > D ES3= Double shield & TVSS—120dB Common > Filtering & Attenuation E TV= Secondary side TVSS (90kA Standard) with common mode noise attenuation F TB= Terminal Block G S= Super Energy Efficient (HM1S & HM2S) 햲 List Price $ 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 Selection HMTs are also available with 480 - 277/480 (3F5), 208–120/208 (3B3), 208–277/480 (3B5). Standard Features Include: ▪ K-13 Load profile rating. ▪ TP1 Efficiencies @ 35% and 65% load. ▪ (C) Copper windings. ▪ (ES) Electrostatic shield. ▪ 130 C Winding rise. 80C Rise HMT Catalog Number 3F3Y015BHM100 3F3Y015BHM130 3F3Y015BHM203 3F3Y015BHM215 3F3Y015BHM2PN15 3F3Y030BHM100 3F3Y030BHM130 3F3Y030BHM203 3F3Y030BHM215 3F3Y030BHM2PN15 3F3Y045BHM100 3F3Y045BHM130 3F3Y045BHM203 3F3Y045BHM215 3F3Y045BHM2PN15 3F3Y075BHM100 3F3Y075BHM130 3F3Y075BHM203 3F3Y075BHM215 3F3Y075BHM2PN15 3F3Y112BHM100 3F3Y112BHM130 3F3Y112BHM203 3F3Y112BHM215 3F3Y112BHM2PN15 3F3Y150BHM100 3F3Y150BHM130 3F3Y150BHM203 3F3Y150BHM215 3F3Y150BHM2PN15 3F3Y225BHM100 3F3Y225BHM130 3F3Y225BHM203 3F3Y225BHM215 3F3Y225BHM2PN15 3F3Y300BHM100 3F3Y300BHM130 3F3Y300BHM203 3F3Y300BHM215 3F3Y300BHM2PN15 3F3Y500BHM100 3F3Y500BHM130 3F3Y500BHM203 3F3Y500BHM215 3F3Y500BHM2PN15 List Price $ 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 햲 Adder to Base $ CSO CSO CSO CSO CSO CSO CSO List Price Adder $ Thermal Sensors 170° C= (TS7), 185° C= (TS8) or 200° C= (TS0) H TS7 = 1 sensor center coil H TS72 = 2 sensors center coil H TS76 = 6 sensors, (2) on each coil H TS8 = 1 sensor center coil H TS82 = 2 sensors center coil H TS86 = 6 sensors, (2) on each coil H H H TS0 = 1 sensor center coil TS02 = 2 sensors center coil TS06 = 6 sensors, (2) on each coil Contact Sales Office for pricing. 7-16 Secondary Configuration Enclosure Optional HMT Outputs Phase Shift Style Modifications 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented A,B,C,D,E,F,G,H 1 30 Deg Lagging Vented A,B,C,D,E,F,G,H 2 0 & 30 Lagging Vented A,B,C,D,E,F,G,H 2 15 & 45 Lagging Vented A,B,C,D,E,F,G,H 2 15 Pos & 15 Neg Vented A,B,C,D,E,F,G,H 1 Zero Degree Vented C,D,E,F,G,H 1 30 Deg Lagging Vented C,D,E,F,G,H 2 0 & 30 Lagging Vented C,D,E,F,G,H 2 15 & 45 Lagging Vented C,D,E,F,G,H 2 15 Pos & 15 Neg Vented C,D,E,F,G,H Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog CSO CSO CSO CSO CSO CSO CSO CSO CSO Reduced Size Transformers Three Phase Selection Sentron Reduced Size Plus (RSP) The “Sentron Reduced Size Plus” is ideal for locations with limited equipment space. This product is specifically designed for easier installation with sufficiently sized bus and all around access for cable entry from bottom, lower back or sides. The rodent proof grillwork at the bottom slides up for insertion of forks or pallet jack for easy positioning. The RSP has 3-phase shunt-trip activated disconnect installed on the primary side and a safety alarm feature which operates automatically if the coils overheat due to severe load or in case of failure as life expectancy is reached. The “RSP” is a dry type transformer with fan assisted cooling activated by thermal sensors only when needed for peak periods and heavy loading. The RSP system incorporates dry contacts to indicate 3 different temperature levels for customers wishing to monitor the transformer remotely. Audible noise insulation barriers are factory installed inside of the enclosure for quieter operation for average applications. The “Sentron Reduced Size Plus” is available with copper or aluminum windings in 150C, 115C or 80C rise as well as K-Factor, electrostatic shielding and TP1 efficiency ratings. Features: 7 ▪ Approximately 30% smaller and 40% lighter ▪ Built to NEMA ST-20 standards, IEEE C57 and UL Listed ▪ 3-phase disconnect switch factory installed on primary. Protection from overheating with shunt trip device. ▪ Easy connection to LV lug landing pads ▪ Lugs provided on disconnect for HV connections to disconnect ▪ Cable entrance from lower back, sides or bottom ▪ Quiet operation for average applications; 2 dB below NEMA std. ▪ Thermal switches activate (Fans) @125˚C, (Alarm) @190˚C and (Disconnect) @200˚C. ▪ Greater efficiency than standard models ▪ Dry contacts for remote monitoring connections ▪ Same distance to wall as standard units ▪ Front access for easy maintenance ▪ Enclosure is rodent proof by design ▪ Audible safety alarm to signal overheating ▪ NEMA 3R with weather shields added ▪ Energy efficient NEMA-TP1 designs TRANSFORMERS Sizes Available: 150-1000 KVA. SMALLER LIGHTER QUIETER ENERGY EFFICIENT Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-17 Warehouse Stock Transformers Type QST [Standard Units] Catalog Number KVA List Price $ Selection Taps Temperature Rise Insulation Mounting Type Drip Shield Required Enclosure Style Single Phase 240 ⴒ 480 Volts Primary, 120/240 Volts Secondary .05 .075 .10 .15 .25 .50 .75 1.0 1.5 2.0 3.0 5.0 7.5 10 15 25 37.5 50 75 100 167 1D1N555QST 1D1N775QST 1D1N110QST 1D1N115QST 1D1N205QST 1D1N505QST 1D1N705QST 98.00 114.00 114.00 163.00 164.00 255.00 381.00 N N N N N N N 115° 115° 115° 115° 115° 115° 115° C C C C C C C 180° 180° 180° 180° 180° 180° 180° C C C C C C C Wall Wall Wall Wall Wall Wall Wall None None None None None None None Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 1D1N001QST 1D1N105QST 1D1N002QST 1D1N003QST 1D1N005QST 1D1N007QST 1D1N010QST 1D1N015QST 380.00 552.00 631.00 769.00 968.00 1405.00 1603.00 1868.00 N N N N N N N N 115° 115° 115° 115° 115° 115° 115° 115° C C C C C C C C 180° 180° 180° 180° 180° 180° 180° 180° C C C C C C C C Wall Wall Wall Wall Wall Wall Wall Wall None None None None None None None None Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated 5283.00 6720.00 7737.00 10254.00 21106.00 32804.00 Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° C C C C C C 220° 220° 220° 220° 220° 220° C C C C C C Floor Floor Floor Floor Floor Floor DSK11Q DSK12Q DSK12Q DSK12Q DSK15Q DSK15Q Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated None None None Encapsulated Encapsulated Encapsulated 1D1Y025TP1QST 1D1Y037TP1QST 1D1Y050TP1QST 1D1Y075TP1QST 1D1Y100TP1QST 1D1Y167TP1QST & & & & Wall Wall Wall Wall Three Phase 480 Volts Δ Primary, 208Y/120 Volts Secondary 3 6 9 3F3R003QST 3F3R006QST 3F3R009QST TRANSFORMERS 7 15 30 45 75 112.5 150 225 300 500 3F3Y015TP1QST 3F3Y030TP1QST 3F3Y045TP1QST 3F3Y075TP1QST 3F3Y112TP1QST 3F3Y150TP1QST 3F3Y225RTP1QST 3F3Y300RTP1QST 3F3Y500RTP1QST 1807.00 1899.00 2735.00 R R R 115° C 115° C 115° C 180° C 180° C 180° C Wall Wall Wall 4246.00 6468.00 6494.00 9244.00 11607.00 15472.00 24774.00 34349.00 54933.00 Y Y Y Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° 150° 150° 150° 220° 220° 220° 220° 220° 220° 220° 220° 220° Floor Floor Floor Floor Floor Floor Floor Floor Floor & & & & Wall Wall Wall Wall DSK31Q DSK11Q DSK11Q DSK12Q DSK12Q DSK34Q DSK15Q DSK36Q DSK37Q Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated Floor Floor Floor Floor Floor Floor & & & & Wall Wall Wall Wall DSK31Q DSK11Q DSK11Q DSK12Q DSK12Q DSK34Q Ventilated Ventilated Ventilated Ventilated Ventilated Ventilated C C C C C C C C C C C C C C C C C C Three Phase 480 Volts Δ Primary, 240 Volts Δ Secondary With 120 Volt Tap On B Phase 15 30 45 75 112.5 150 3F1Y015TP1QST 3F1Y030TP1QST 3F1Y045TP1QST 3F1Y075TP1QST 3F1Y112TP1QST 3F1Y150TP1QST 4204.00 6562.00 6648.00 9606.00 13152.00 15852.00 Y Y Y Y Y Y 150° 150° 150° 150° 150° 150° C C C C C C 220° 220° 220° 220° 220° 220° C C C C C C Taps Description Designation 4–3% (2 FCAN, 2 FCBN) 2–3.5% (1 FCAN, 1 FCBN) 3–5% (1 FCAN, 2 FCBN) None 2–5% FCBN 2–5% (1 FCAN, 1 FCBN) 4–2.5% (2 FCAN, 2 FCBN) 2–2.5% FCBN 4–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) J K M N R S T U X Y Actual taps are shown for warehouse stock transformers. designations for units having standard features. outdoor application. Ventilated transformers requiring drip shields are UL listed for outdoor use. Encapsulated transformers are UL listed for indoor/ outdoor use. Wall Reduced capacity 1-phase tap—5% of rated KVA (2.5% on each side of lighting tap). For 7-18 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog = Warehouse Stock Discount Schedule XFMR Warehouse Stock Transformers Type QST and Buck-Boost Transformers Selection Encapsulated, Indoor/Outdoor Enclosure, 115° C Rise 120 ⴒ 240 Volts — 12/24 Volts, 60 Hz, No Taps, Wall Mounted 120 ⴒ 240 Volts — 16/32 Volts, 60 Hz, No Taps, Wall Mounted 240 ⴒ 480 Volts — 24/48 Volts, 60 Hz, No Taps, Wall Mounted Catalog Number KVA List Price $ Catalog Number KVA List Price $ Catalog Number KVA List Price $ 050BB1224Q 100BB1224Q 150BB1224Q 205BB1224Q 505BB1224Q 705BB1224Q 1BB1224Q 105BB1224Q 2BB1224Q 3BB1224Q 5BB1224Q .050 .100 .150 .250 .500 .750 1.00 1.50 2.00 3.00 5.00 241.00 278.00 334.00 391.00 539.00 688.00 890.00 1077.00 1318.00 1763.00 2525.00 050BB1632Q 100BB1632Q 150BB1632Q 205BB1632Q 505BB1632Q 705BB1632Q 1BB1632Q 105BB1632Q 2BB1632Q 3BB1632Q 5BB1632Q .050 .100 .150 .250 .500 .750 1.00 1.50 2.00 3.00 5.00 241.00 278.00 334.00 391.00 539.00 688.00 890.00 1077.00 1318.00 1763.00 2525.00 050BB2448Q 100BB2448Q 150BB2448Q 205BB2448Q 505BB2448Q 705BB2448Q 1BB2448Q 105BB2448Q 2BB2448Q 3BB2448Q 5BB2448Q .050 .100 .150 .250 .500 .750 1.00 1.50 2.00 3.00 5.00 278.00 334.00 372.00 447.00 613.00 780.00 983.00 1188.00 1448.00 1763.00 3694.00 Accessories Dripshield/Weathershield Kits for Type QST Ventilated Transformers Single Phase Three Phase Single Phase Three Phase Single Phase Three Phase Catalog Number 150˚C Rise & TP1 150˚C Rise & TP1 115˚C Rise & TP1 115˚C Rise & TP1 80˚C Rise & TP1 80˚C Rise & TP1 KVA Sizes KVA Sizes KVA Sizes KVA Sizes KVA Sizes KVA Sizes Nameplate Ref. # DSK11Q DSK12Q DSK34Q DSK15Q DSK36Q DSK37Q DSK31Q DSK38Q 25 37.5, 50, 75 — 100, 167 — — — — 30, 45 75, 112.5 150 225 300 500 15 750, 1000 — 25, 37.5, 50 — 75, 100 — — — — 30 45, 75 112.5 150 225 300 15 500, 750 — 25, 37.5 — 50, 75, 100 — — — — 15, 30 45, 75 — 112.5, 150 — — — 500 4317G05 4317G06 4317G07 4317G08 4317G09 4317G10 4317G11 4317G67 Wall Mounting Brackets for Type QST Ventilated Transformers Catalog Number WMB42Q WMB43Q Single Phase Three Phase Single Phase Three Phase Single Phase Three Phase 150˚C Rise & TP1 150˚C Rise & TP1 115˚C Rise & TP1 115˚C Rise & TP1 80˚C Rise & TP1 80˚C Rise & TP1 KVA Sizes KVA Sizes KVA Sizes KVA Sizes KVA Sizes KVA Sizes 25 37.5, 50 15, 30, 45 75 — 25, 37.5 15, 30 45 — 25 15, 30 45 Terminal Lug Kits For Ventilated Transformers TLK32Q TLK11Q — 25, 37.5 TLK13Q 75 TLK33Q — TLK12Q Three Phase KVA Sizes List Price $ 65.00 Terminal Lug Qty. Terminal Lug Cable Range Qty. 14awg-1/0mcm n/a Hardware Included 7 141.00 127.00 7 8 KA29U/TA250 6awg-250mcm KA29U/TA250 6awg-250mcm n/a n/a — 75 279.00 12 KA29U/TA250 6awg-250mcm n/a 243.00 3 KA29U/TA250 6awg-250mcm 8 KA31U/TA350 6awg-350mcm 3, 8 (3) 5/16" x 1 1/2" 50 — 191.00 4 KA29U/TA250 6awg-250mcm 4 KA31U/TA350 6awg-350mcm 8 (8) 3/8" x 1 1/2" 3/8" x 1 1/2" 3/8" x 1 1/2" 15 30, 45 — Lug No. Cable Range Lug No. KA25U/TA0 Qty. Bolt Size 7 1/4" x 1" 7 8 12 5/16" x 1 1/2" 5/16" x 1 1/2" 5/16" x 1 1/2" TLK34Q — 112.5 243.00 11 KA31U/TA350 6awg-350mcm n/a 11 TLK36Q — 225 459.00 22 KA31U/TA350 6awg-350mcm n/a 22 3/8" x 1 1/2" TLK35Q — 150 396.00 3 KA31U/TA350 6awg-350mcm 8 KA34U/TA500 4awg-500mcm 11 3/8" x 1 1/2" TLK37Q — 300 638.00 6 KA31U/TA350 6awg-350mcm 16 KA34U/TA500 4awg-500mcm 22 3/8" x 1 1/2" TLK15Q 167 — 562.00 8 KA31U/TA350 6awg-350mcm 12 KA34U/TA500 4awg-500mcm 20 3/8" x 1 1/2" TLK38Q — 500 1150.00 9 KA31U/TA350 6awg-350mcm 24 KA34U/TA500 4awg-500mcm 33 3/8" x 1 1/2" TLK14Q 100 — 279.00 12 KA31U/TA350 6awg-350mcm n/a TLK39Q — 750 1430.00 12 KA31U/TA350 6awg-350mcm 28 These accessories fit only warehouse stock transformers with QST Catalog Suffix. Listed for indoor and outdoor use with dripshield installed. UL Discount Schedule XFMR May be used on “QST” suffix units and “non QST” suffix transformers. Terminal lugs are screw type, lug connectors suitable for both copper and aluminum cable. TA lugs are single barrel, AU lugs are double barrel. Each barrel is suitable for cable range shown. Lugs are rated 90° C KA34U/TA500 4awg-500mcm Lug 12 3/8" x 1 1/2" 40 3/8" x 1 1/2" kit contains quantity required for each transformer. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-19 TRANSFORMERS Single Phase KVA Sizes — 7 Catalog Number TLK31Q Warehouse Stock Transformers Warehouse Stock TRANSFORMERS 7 Application The Buck-Boost Transformer has four separate windings, two-windings in the primary and two-windings in the secondary. The unit is designed for use as an insulating transformer or as an autotransformer. As an autotransformer the unit can be connected to Buck (decrease) or Boost (increase) a supply voltage. When connected in either the Buck or Boost mode, the unit is no longer an insulating transformer but is an autotransformer. Units are designed for 60Hz applications. Autotransformers are more economical and physically smaller than equivalent twowinding transformers and are designed to carry the same function as two-winding transformers, with the exception of isolating two circuits. Since autotransformers may transmit line disturbances directly, they may be prohibited in some areas by local building codes. Before applying them, care should be taken to assure that they are acceptable according to local code. NOTE: Autotransformers are not used in closed delta connections as they introduce into the circuit a phase shift which makes them uneconomical. As insulating transformers these units can accommodate a high voltage of 120, 240 or 480 volts. For units with two 12 volt secondaries, two 16 volt secondaries, or two 24 volt secondaries, the output can be wired for either secondary voltage, or for 3-wire secondary. The unit is rated (KVA) as any conventional transformer. Operation Electrical and electronic equipment is designed to operate on a standard supply voltage. When the supply voltage is constantly too high or too low, (usually greater than ± 5%), the equipment fails to operate at maximum efficiency. A Buck-Boost transformer is a simple and economical 7-20 Selection means of correcting this off-standard voltage up to ± 20%. A Buck-Boost transformer will NOT, however, stabilize a fluctuating voltage. Buck-Boost transformers are suitable for use in a three phase autotransformer bank in either direction to supply 3-wire loads. They are also suitable for use in a three phase autotransformer bank which provides a neutral return for unbalanced current. They are NOT suitable for use in a three phase autotransformer bank to supply a 4-wire unbalanced load when the source is a 3-wire circuit. Construction Buck-Boost Transformers are contained within a NEMA 3R, non-ventilated weatherproof enclosure. Wiring compartments are located at the bottom. Core and coil assemblies are encapsulated. Insulation system temperature is 180˚ C and the winding temperature rise is 115˚ C. Coils are copper wound through 3 kva. How To Select The Proper Transformer To select the proper Transformer for BuckBoost applications, determine: 1. Input line voltage — The voltage that you want to buck (decrease) or boost (increase). This can be found by measuring the supply line voltage with a voltmeter. 2. Load voltage — The voltage at which your equipment is designed to operate. This is listed on the nameplate of the load equipment. 3. Load KVA or Load Amps — You do not need to know both — one or the other is sufficient for selection purposes. This information usually can be found on the nameplate of the equipment that you want to operate. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 4. Number of phases — Single or three phase line and load should match because a transformer is not capable of converting single to three phase. It is however a common application to make a single phase transformer connection from a three phase supply by use of one leg of the three phase supply circuit. Care must always be taken not to overload the leg of the three phase supply. This is particularly true in a Buck-Boost application because the supply must provide for the load KVA, not just the nameplate rating of the Buck-Boost transformer. 5. Frequency — The supply line frequency must be the same as the frequency of the equipment to be operated — either 50 or 60 cycles. How To Use Selection Charts 1. Choose the selection table with the correct number of phases for single or three phase applications. 2. Line/Load voltage combinations are listed across the top of the selection table. Select a line/load voltage combination which comes closest to matching your applications. 3. Follow the selected column down until you find either the KVA or load amps of your application. If you do not find the exact value, go on the next highest rating. 4. Now follow across the table to the far left-hand side to find the catalog number and the KVA of the transformer you need. 5. Follow the column of your line/load voltage to the bottom to find the connection diagram for this application. NOTE: Connection diagrams show low voltage and high voltage connection terminals. Either can be input or output depending on Buck or Boost application. 6. In the case of three phase loads either wo or three single phase transformers are required as indicated in the “quantity required” line at the bottom of the table. The selection is dependent on whether a Wye connected bank of three transformers with a neutral is required or whether an open Delta connected bank of two ransformers for a Delta connected load will be suitable. 7. For line/load voltage not listed on the selection tables, use the pair listed on the table that is slightly above your application for reference. Then apply the first formula at the bottom of the table to determine “new” output voltage. The new KVA rating can be found using the second formula. Warehouse Stock Transformers Buck-Boost Selection 120 ⴒ 240 Volts Primary — 12/24 Volts Secondary, 60 Hz, No Taps, Wall Mounted Single Phase — Table 1 Boosting Bucking Catalog Number Line Voltage (Available) 96 100 105 109 189 208 215 220 125 132 229 245 250 252 Insulating Transformer Rating Load Voltage (Output) 115 120 115 120 208 229 237 242 114 120 208 222 227 240 050BB1224Q .050 KVA Load KVA Amps .24 2.08 .25 2.08 .50 4.17 .50 4.17 .43 2.08 .48 2.08 .49 2.08 .50 2.08 .52 4.59 .55 4.59 .48 2.29 .51 2.29 .52 2.29 1.05 4.38 100BB1224Q .100 KVA Load KVA Amps .48 4.17 .50 4.17 .96 8.33 1.00 8.33 .87 4.17 .95 4.17 .99 4.17 1.01 4.17 1.04 9.16 1.10 9.16 .95 4.58 1.02 4.58 1.04 4.58 2.10 8.75 150BB1224Q .150 KVA Load KVA Amps .72 6.25 .75 6.25 1.44 12.50 1.50 12.50 1.30 6.25 1.43 6.25 1.48 6.25 1.51 6.25 1.55 13.75 1.65 13.75 1.43 6.88 1.53 6.88 1.56 6.88 3.15 13.13 205BB1224Q .250 KVA Load KVA Amps 1.19 10.42 1.25 10.42 2.40 20.83 2.50 20.83 2.17 10.42 2.38 10.42 2.47 10.42 2.52 10.42 2.60 22.92 2.75 22.92 2.38 11.46 2.54 11.46 2.60 11.46 5.25 21.88 505BB1224Q .500 KVA Load KVA Amps 2.37 20.83 2.50 20.83 4.80 41.67 5.00 41.67 4.33 20.83 4.77 20.83 4.94 20.83 5.04 20.83 5.18 45.83 5.50 45.83 4.77 22.92 5.09 22.92 5.20 22.92 10.50 43.75 705BB1224Q .750 KVA Load KVA Amps 3.56 31.25 3.75 31.25 7.19 62.50 7.50 62.50 6.50 31.25 7.15 31.25 7.41 31.25 7.56 31.25 7.77 68.75 8.25 68.75 7.15 34.38 7.63 34.38 7.80 34.38 15.75 65.63 1BB1224Q 1.00 KVA Load KVA Amps 4.75 41.67 5.00 41.67 9.58 83.33 10.00 83.33 8.67 41.67 9.53 41.67 9.88 41.67 10.08 41.67 10.36 91.66 11.00 91.66 9.53 45.83 10.17 45.83 10.40 45.83 21.00 87.50 105BB1224Q 1.50 KVA Load KVA Amps 7.13 62.50 7.50 62.50 14.38 125.00 15.00 125.00 13.00 62.50 14.30 62.50 14.81 62.50 15.13 62.50 15.54 137.50 16.50 137.50 14.30 68.75 15.26 68.75 15.61 68.75 31.50 131.25 2BB1224Q 2.00 KVA Load KVA Amps 9.50 83.33 10.00 83.33 19.17 166.66 20.00 166.66 17.33 83.33 19.07 83.33 19.75 83.33 20.17 83.33 20.72 183.33 22.00 183.33 19.07 91.66 20.35 91.66 20.81 91.66 42.00 175.00 3BB1224Q 3.00 KVA Load KVA Amps 14.25 15.00 125.00 125.00 28.75 250.00 30.00 250.00 26.00 125.00 28.60 125.00 29.63 125.00 30.25 125.00 31.08 275.00 33.00 275.00 28.60 137.50 30.53 137.50 31.21 137.50 63.00 262.50 5BB1224Q 5.00 KVA Load KVA Amps 23.75 25.00 208.33 208.33 47.92 416.66 50.00 416.66 43.33 208.33 47.67 208.33 49.37 208.33 50.42 208.33 51.79 458.33 55.00 458.33 47.67 229.17 50.88 229.17 52.02 229.17 105.00 437.50 Connection Diagram (pg. 7-24) B B B A A D D D D A A D D C Three Phase — Table 2 Boosting Catalog Number Line Voltage (Available) 189Y/ 109 195Y/ 113 200Y/ 115 208Y/ 120 416Y/ 240 416Y/ 240 189 208 220 218 229 250 255 264 Insulating Transformer Rating Load Voltage (Output) 208Y/ 120 234Y/ 135 240Y/ 139 229Y/ 132 458Y/ 264 437Y/ 252 208 229 242 208 208 227 232 240 Bucking KVA Amps 1.50 4.17 .84 2.08 .86 2.08 1.65 4.17 1.65 2.08 3.15 4.17 .75 2.08 .83 2.08 .87 2.08 1.58 4.39 .83 2.29 .90 2.29 .92 2.29 .95 2.29 100BB1224Q .100 KVA Load KVA Amps 3.00 8.33 1.69 4.17 1.73 4.17 3.30 8.33 3.30 4.17 6.29 8.33 1.50 4.17 1.65 4.17 1.75 4.17 3.15 8.75 1.65 4.58 1.80 4.58 1.84 4.58 1.90 4.58 150BB1224Q .150 KVA Load KVA Amps 4.50 12.50 2.54 6.25 2.60 6.25 4.96 12.50 4.96 6.25 9.44 12.50 2.26 6.25 2.48 6.25 2.62 6.25 4.73 13.13 2.48 6.88 2.71 6.88 2.76 6.88 2.86 6.88 205BB1224Q .250 KVA Load KVA Amps 7.50 20.83 4.22 10.42 4.33 10.42 8.30 20.83 8.25 10.42 15.75 20.83 3.75 10.42 4.13 10.42 4.37 10.42 7.88 21.88 4.13 11.46 4.50 11.46 4.61 11.46 4.76 11.46 505BB1224Q .500 KVA Load KVA Amps 15.01 41.67 8.44 20.83 8.66 20.83 16.60 41.67 16.50 20.83 31.50 41.67 7.50 20.83 8.26 20.83 8.73 20.83 15.76 43.75 8.26 22.92 9.01 22.92 9.21 22.92 9.53 22.92 705BB1224Q .750 KVA Load KVA Amps 22.52 62.50 12.67 31.25 12.99 31.25 24.90 62.50 24.75 31.25 47.25 62.50 11.26 31.25 12.39 31.25 13.10 31.25 23.64 65.63 12.39 34.38 13.52 34.38 13.82 34.38 14.29 34.38 1BB1224Q 1.00 KVA Load KVA Amps 30.02 83.33 16.89 41.67 17.32 41.67 33.20 83.33 33.00 41.67 63.00 83.33 15.01 41.67 16.51 41.67 17.47 41.67 31.52 87.50 16.51 45.83 18.02 45.83 18.42 45.83 19.05 45.53 105BB1224Q 1.50 KVA Load KVA Amps 45.03 125.00 25.33 62.50 25.98 62.50 49.80 125.00 49.50 62.50 94.50 125.00 22.52 62.50 24.77 62.50 26.20 62.50 47.28 131.25 24.77 68.75 27.03 68.75 27.63 68.75 28.53 68.75 2BB1224Q 2.00 KVA Load KVA Amps 60.06 166.67 33.77 83.33 34.64 83.33 66.40 166.67 66.00 83.33 126.00 166.66 30.02 83.33 33.03 83.33 34.93 83.33 63.05 175.00 33.03 91.67 36.04 91.67 36.84 91.67 38.11 91.67 3BB1224Q 3.00 KVA Load KVA Amps 90.07 50.66 250.00 125.00 51.96 125.00 99.59 250.00 99.00 125.00 189.00 250.00 45.03 125.00 49.54 125.00 52.39 125.00 94.57 262.50 49.54 137.50 54.06 137.50 55.25 137.50 57.16 137.50 5BB1224Q 5.00 KVA Load KVA Amps 150.11 84.44 416.67 208.33 86.60 208.33 165.99 416.67 165.00 208.33 318.00 416.66 75.05 208.33 82.56 208.33 87.32 208.33 157.62 437.50 82.56 229.17 90.10 229.17 92.09 229.17 95.26 229.17 Quantity Required 3 3 3 3 3 3 2 2 2 2 2 2 2 2 Connection Diagram (pg. 7-24) F E E F J K G G G H G G G G = Warehouse Stock • Output voltage for lower input voltage can be found by: Rated Output Voltage ⴒ Input Actual Voltage = Output New Voltage. Rated Input Voltage • Output KVA available at reduced input voltage can be found by: Actual Input Voltage Rated Input Voltage ⴒ Output KVA = New KVA Rating. • Inputs and outputs may be reversed without affecting KVA capacity. See note on page 7-24 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-21 TRANSFORMERS Load 7 050BB1224Q .050 KVA Warehouse Stock Transformers Buck-Boost Selection 120 ⴒ 240 Volts Primary — 16/32 Volts Secondary, 60 Hz, No Taps, Wall Mounted TRANSFORMERS 7 Single Phase — Table 3 Boosting Bucking Catalog Number Line Voltage (Available) 95 100 105 208 215 215 220 225 135 240 240 245 250 255 Insulating Transformer Rating Load Voltage (Output) 120 113 119 236 244 229 235 240 120 212 225 230 234 239 050BB1632Q .050 KVA Load KVA Amps .19 1.56 .36 3.12 .37 3.12 .37 1.56 .38 1.56 .72 3.12 .73 3.12 .73 3.12 .42 3.54 .37 1.77 .75 3.33 .77 3.33 .78 3.33 .80 3.33 100BB1632Q .100 KVA Load KVA Amps .38 3.13 .72 6.25 .74 6.25 .74 3.13 .76 3.13 1.44 6.25 1.46 6.25 1.50 6.25 .84 7.09 .74 3.54 1.50 6.66 1.54 6.66 1.56 6.66 1.60 6.66 150BB1632Q .150 KVA Load KVA Amps .56 4.69 1.06 9.38 1.12 9.38 1.12 4.69 1.14 4.69 2.16 9.38 2.20 9.38 2.26 9.38 1.26 10.64 1.10 5.30 2.26 10.02 2.30 10.02 2.34 10.02 2.40 10.02 205BB1632Q .250 KVA Load KVA Amps .94 7.81 1.78 15.63 1.86 15.63 1.88 7.81 1.91 7.81 3.59 15.63 3.67 15.63 3.75 15.63 2.11 17.71 1.84 8.85 3.75 16.67 3.83 16.67 3.90 16.67 3.98 16.67 505BB1632Q .500 KVA Load KVA Amps 1.88 15.63 3.56 31.25 3.72 31.25 3.75 15.63 3.81 15.63 7.19 31.25 7.34 31.25 7.50 31.25 4.21 35.42 3.68 17.71 7.50 33.33 7.67 33.33 7.80 33.33 7.97 33.33 705BB1632Q .750 KVA Load KVA Amps 2.81 23.44 5.34 46.88 5.58 46.88 5.63 23.44 5.72 23.44 10.78 46.88 11.02 46.88 11.25 46.88 6.32 53.13 5.53 26.56 11.25 50.00 11.50 50.00 11.70 50.00 11.95 50.00 1BB1632Q 1.00 KVA Load KVA Amps 3.75 31.25 7.13 62.50 7.44 62.50 7.50 31.25 7.63 31.25 14.38 62.50 14.69 62.50 15.00 62.50 8.43 70.83 7.37 35.42 15.00 66.67 15.33 66.67 15.60 66.67 15.93 66.67 105BB1632Q 1.50 KVA Load KVA Amps 5.63 43.90 10.69 93.80 11.16 93.80 11.25 46.90 11.44 46.90 21.56 93.80 22.03 93.80 22.50 93.80 12.64 106.30 11.05 53.10 22.50 100.00 23.00 100.00 23.40 100.00 23.90 100.00 2BB1632Q 2.00 KVA Load KVA Amps 7.50 14.25 62.50 125.00 14.88 125.00 15.00 62.50 15.25 62.50 28.75 125.00 29.38 125.00 30.00 125.00 16.86 141.70 14.73 70.80 30.00 133.30 30.67 133.30 31.20 133.30 31.87 133.30 3BB1632Q 3.00 KVA Load KVA Amps 11.25 21.38 93.80 187.50 22.31 187.50 22.50 93.80 22.88 93.80 43.13 187.50 44.06 187.50 45.00 187.50 25.29 212.50 22.10 106.30 45.00 200.00 46.00 200.00 46.80 200.00 47.80 200.00 5BB1632Q 5.00 KVA Load KVA Amps 18.75 35.63 156.30 312.50 37.19 312.50 37.50 156.30 38.13 156.30 71.88 312.50 73.44 312.50 75.00 312.50 42.15 354.20 36.83 177.10 75.00 333.30 76.67 333.30 78.00 333.30 79.67 333.30 Connection Diagram (pg. 7-24) B A D D C C C A D C C C C Three Phase — Table 4 Boosting A Bucking Catalog Number Line Voltage (Available) 183Y/ 106 208Y/ 120 195 208 225 240 245 250 256 265 272 Insulating Transformer Rating Load Voltage (Output) 208Y/ 120 236Y/ 136 208 236 240 208 230 234 240 234 240 050BB1632Q .050 KVA Load KVA Amps 1.13 3.13 1.28 3.13 1.13 3.13 .62 1.56 1.30 3.13 .56 1.56 1.33 3.34 1.35 3.34 1.39 3.34 .72 1.77 .74 1.77 100BB1632Q .100 KVA Load KVA Amps 2.25 6.25 2.55 6.25 2.25 6.25 1.30 3.13 2.60 6.25 1.13 3.13 2.66 6.67 2.70 6.67 2.77 6.67 1.44 3.55 1.48 3.55 150BB1632Q .150 KVA Load KVA Amps 3.38 9.38 3.83 9.38 3.38 9.38 1.95 4.69 3.90 9.38 1.69 4.69 3.98 10.00 4.05 10.00 4.16 10.00 2.15 5.31 2.21 5.31 205BB1632Q .250 KVA Load KVA Amps 5.63 15.63 6.39 15.63 5.63 15.63 3.17 7.81 6.50 15.63 2.81 7.81 6.64 16.67 6.76 16.67 6.93 16.67 3.59 8.85 3.68 8.85 505BB1632Q .500 KVA Load KVA Amps 11.26 31.25 12.77 31.26 11.26 31.25 6.33 15.63 12.99 31.25 5.63 15.63 13.28 33.33 13.50 33.33 13.86 33.33 7.17 17.69 7.36 17.71 705BB1632Q .750 KVA Load KVA Amps 16.89 46.88 19.16 46.88 16.89 46.88 9.50 23.44 19.49 46.88 8.44 23.44 19.92 50.00 20.26 50.00 20.78 50.00 10.76 26.54 11.04 26.56 1BB1632Q 1.00 KVA Load KVA Amps 22.52 62.50 25.55 62.50 22.52 62.50 12.67 31.25 25.98 62.50 11.26 31.25 26.56 66.67 27.02 66.67 27.71 66.67 14.34 35.39 14.72 35.42 105BB1632Q 1.50 KVA Load KVA Amps 33.77 93.75 38.32 93.75 33.77 93.75 19.00 46.88 38.97 93.75 16.89 46.88 39.84 100.00 40.53 100.00 41.57 100.00 21.52 53.08 22.08 53.13 2BB1632Q 2.00 KVA Load KVA Amps 45.03 125.00 51.10 125.00 46.03 125.00 25.33 62.50 51.96 125.00 22.52 62.50 53.11 133.33 54.04 133.33 55.43 133.33 28.69 70.78 29.44 70.83 3BB1632Q 3.00 KVA Load KVA Amps 67.55 187.50 76.64 187.50 67.55 187.50 38.00 93.75 77.94 187.50 33.77 93.75 79.67 200.00 81.06 200.00 83.14 200.00 43.03 106.17 44.17 106.25 5BB1632Q 5.00 KVA Load KVA Amps 112.58 312.50 127.74 312.50 112.58 312.50 63.33 156.25 129.90 312.50 56.29 156.25 132.79 333.33 135.09 333.33 138.56 333.33 71.72 176.95 73.61 177.08 Quantity Required 3 3 2 2 2 2 2 2 2 2 2 Connection Diagram (pg. 7-24) F F H G H L H H H G G = Warehouse Stock • Output KVA available at reduced input voltage can be found by: Actual Input Voltage ⴒ Output KVA = New KVA Rating. Rated Input Voltage 7-22 • Output KVA available at reduced input voltage can be found by: Actual Input Voltage Rated Input Voltage ⴒ Output KVA = New KVA Rating. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Warehouse Stock Transformers Buck-Boost Selection 240 ⴒ 480 Volts Primary — 24/48 Volts Secondary, 60 Hz, No Taps, Wall Mounted Single Phase — Table 5 Boosting Catalog Number Line Voltage (Available) 230 380 416 425 430 435 440 450 450 460 Bucking 277 480 480 504 Insulating Transformer Rating Load Voltage (Output) 276 418 458 468 473 457 462 495 472 483 231 436 457 480 050BB2448Q .050 KVA Load KVA Amps .29 1.04 .44 1.04 .48 1.04 .49 1.04 .49 1.04 .95 2.08 .96 2.08 .52 1.04 .98 2.08 1.01 2.08 .29 1.25 .50 1.15 1.00 2.19 1.05 2.19 100BB2448Q .100 KVA Load KVA Amps .58 2.08 .87 2.08 .95 2.08 .97 2.08 .99 2.08 1.90 4.17 1.93 4.17 1.03 2.08 1.97 4.17 2.01 4.17 .58 2.50 1.00 2.29 2.00 4.38 2.10 4.38 150BB2448Q .150 KVA Load KVA Amps .86 3.13 1.31 3.13 1.43 3.13 1.46 3.13 1.48 3.13 2.86 6.25 2.89 6.25 1.55 3.13 2.95 6.25 3.02 6.25 .86 3.75 1.50 3.44 3.00 6.56 3.15 6.56 205BB2448Q .250 KVA Load KVA Amps 1.44 5.21 2.18 5.21 2.38 5.21 2.43 5.21 2.46 5.21 4.76 5.21 4.81 10.42 2.58 5.21 4.92 10.42 5.03 10.42 1.44 6.25 2.50 5.73 5.00 10.94 5.25 10.94 505BB2448Q .500 KVA Load KVA Amps 2.88 10.42 4.35 10.42 4.77 10.42 4.87 10.42 4.93 10.42 9.52 20.83 9.62 20.83 5.16 10.42 9.83 20.83 10.06 20.83 2.88 12.50 5.00 11.46 10.00 21.88 10.50 21.88 705BB2448Q .750 KVA Load KVA Amps 4.31 15.63 6.53 15.63 7.15 15.62 7.30 15.63 7.39 15.63 14.28 31.25 14.44 31.25 7.73 15.63 14.75 31.25 15.09 31.25 4.31 18.75 7.49 17.19 15.00 32.81 15.75 32.81 1BB2448Q 1.00 KVA Load KVA Amps 5.75 20.83 8.71 20.83 9.53 20.83 9.74 20.83 9.85 20.83 19.04 41.67 19.25 41.67 10.31 20.83 19.67 41.67 20.13 41.67 5.75 25.00 9.99 22.92 20.00 43.75 21.00 43.75 105BB2448Q 1.50 KVA Load KVA Amps 8.63 31.25 13.06 31.25 14.30 31.25 14.61 31.25 14.78 31.25 28.56 62.50 28.88 62.50 15.47 31.25 29.50 62.50 30.19 62.50 8.63 37.50 14.99 34.38 30.00 65.63 31.50 65.63 2BB2448Q 2.00 KVA Load KVA Amps 11.50 41.67 17.42 41.67 19.07 41.67 19.48 41.67 19.71 41.67 38.08 83.33 38.50 83.33 20.63 41.67 39.33 83.33 40.25 83.33 11.50 50.00 19.98 45.83 40.00 87.50 42.00 87.50 3BB2448Q 3.00 KVA Load KVA Amps 17.25 62.50 26.13 62.50 28.60 62.50 29.22 62.50 29.56 62.50 57.13 125.00 57.75 125.00 30.94 62.50 59.00 125.00 60.38 125.00 17.25 75.00 29.98 68.80 60.00 131.25 63.00 131.25 5BB2448Q 5.00 KVA Load KVA Amps 28.75 43.54 104.17 104.17 47.67 104.17 48.70 104.17 49.30 104.20 95.20 208.30 96.20 208.30 51.56 104.17 98.30 208.30 100.60 208.30 28.80 125.00 50.00 114.60 100.00 218.75 105.00 218.75 B D D D C C D C C B D C C Connection Diagram (pg. 7-24) D Three Phase — Table 6 Boosting Catalog Number Line Voltage (Available) 399Y/ 380 230 Bucking 430 440 460 460 480 480 440 440 460 460 480 480 500 500 Insulating Transformer Rating Load Voltage (Output) 480Y/ 418 277 473 462 506 483 528 504 400 419 438 418 457 436 455 476 KVA Amps .86 1.04 .75 1.04 .85 1.04 1.66 2.08 .91 1.04 1.74 2.08 .95 1.04 1.82 2.08 .79 1.14 1.58 2.18 1.66 2.18 .83 1.14 1.73 2.18 .86 1.14 .90 1.14 1.80 2.19 100BB2448Q .100 KVA Load KVA Amps 1.73 2.08 1.51 2.08 1.70 2.08 3.33 4.16 1.82 2.08 3.48 4.16 1.90 2.08 3.63 4.16 1.59 2.29 3.17 4.37 3.31 4.37 1.66 2.29 3.46 4.37 1.73 2.29 1.80 2.29 3.61 4.38 150BB2448Q .150 KVA Load KVA Amps 2.60 3.12 2.26 3.13 2.56 3.12 4.99 6.24 2.73 3.12 5.22 6.25 2.85 3.12 5.45 6.24 2.38 3.43 4.75 6.55 4.97 6.55 2.48 3.43 5.19 6.55 2.59 3.43 2.70 3.43 5.41 6.56 205BB2448Q .250 KVA Load KVA Amps 4.33 5.20 3.77 5.21 4.26 5.20 8.32 10.40 4.56 5.20 8.70 10.40 4.76 5.20 9.08 10.40 3.96 5.72 7.92 10.92 8.28 10.92 4.14 5.72 8.64 10.92 4.32 5.72 4.51 5.72 9.02 10.94 505BB2448Q .500 KVA Load KVA Amps 8.60 10.40 7.54 10.42 8.52 10.40 16.64 20.80 9.11 10.40 17.40 20.80 9.51 10.40 18.16 20.80 7.93 11.44 15.85 21.84 16.57 21.84 8.28 11.44 17.29 21.84 8.64 11.44 9.02 11.44 18.04 21.88 705BB2448Q .750 KVA Load KVA Amps 12.90 15.60 11.31 15.63 12.77 15.60 24.97 31.20 13.67 15.60 26.10 31.20 14.27 15.60 27.24 31.20 11.89 17.16 23.77 32.76 24.85 32.76 12.42 17.16 25.93 32.76 12.96 17.16 13.52 17.16 27.06 32.81 1BB2448Q 1.00 KVA Load KVA Amps 17.30 20.80 15.08 20.83 17.03 20.80 33.29 41.60 18.23 20.80 34.80 41.60 19.02 20.80 36.31 41.60 15.85 22.88 31.70 43.68 33.14 43.68 16.57 22.88 34.57 43.68 17.28 22.88 18.03 22.88 36.08 43.75 105BB2448Q 1.50 KVA Load KVA Amps 25.90 31.20 22.62 31.25 25.55 31.20 49.93 62.40 27.34 31.20 52.50 62.40 28.53 31.20 54.47 62.40 23.78 34.32 47.55 65.52 49.71 65.52 24.85 34.32 51.86 65.62 25.92 34.32 27.05 34.32 54.13 65.63 2BB2448Q 2.00 KVA Load KVA Amps 34.60 41.60 30.17 41.67 34.07 41.60 66.58 83.20 36.46 41.60 69.60 83.20 38.04 41.60 72.63 83.20 31.70 45.76 63.40 87.36 66.27 87.36 33.13 45.76 69.15 87.36 34.56 45.76 36.06 45.76 72.17 87.50 3BB2448Q 3.00 KVA Load KVA Amps 52.00 62.50 45.25 62.50 51.18 100.03 62.50 125.00 49.77 103.89 68.75 131.25 51.92 68.75 54.18 108.25 68.75 131.25 5BB2448Q 5.00 KVA Load KVA 86.10 75.42 85.17 166.44 91.15 174.01 95.11 181.57 79.26 158.50 165.69 82.83 172.87 86.39 90.16 180.42 Amps 104.00 104.17 104.00 208.00 104.00 208.00 104.00 208.00 114.40 218.40 218.40 114.40 218.40 114.40 114.40 218.75 54.69 104.57 62.50 125.00 57.07 109.12 62.50 125.00 47.63 95.25 99.57 68.75 131.25 131.25 Quantity Required 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Connection Diagram (pg. 7-24) E G G H G H G H G H H G H G G H = Warehouse Stock • Output voltage for lower input can be found by: Rated Output Voltage ⴒ Input Actual Voltage = Output New Voltage. Rated Input Voltage • Output KVA available at reduced input voltage can be found by: Actual Input Voltage Rated Input Voltage ⴒ Output KVA = New KVA Rating. • Inputs and outputs may be reversed without affecting KVA capacity. See note on page 7-24. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 7-23 TRANSFORMERS Load 7 050BB2448Q .050 KVA Buck-Boost Transformers Single Phase, Three Phase Single Phase Typical Connection Diagrams Three Phase Note: Contact sales office for diagrams applicable to “Q” suffix. Diagram E Diagram A Diagram F Low Voltage High Voltage Diagram G Low Voltage Low Voltage Diagram B High Voltage High Voltage WYE High Voltage Diagram J Open Delta WYE Diagram H High Voltage Low Voltage Low Voltage Diagram C High Voltage Low Voltage High Voltage High Voltage WYE Diagram K Open Delta Diagram L Low Voltage High Voltage 7 Diagram D TRANSFORMERS Low Voltage High Voltage High Voltage Low Voltage WYE Open Delta (Standard Step-down Application)* *Low Voltage Applications: By using the “Standard Step-down Application” diagram at left, buck boost transformers will convert 120V or 240V to 12, 24, 16 or 32 volts and 240V or 480V to 24 or 48 volts without affecting the nameplate KVA rating of the transformer. Buck boost transformers used in this type of application will become isolation or insulating type transformers. These diagrams can only be used when the source is a 4-wire supply. The neutral XO should not be used when the source is a three wire supply. Note: Inputs and Outputs may be reversed; KVA capacity remains constant. Exception: Cannot use 3-wire input with 4-wire output to form a neutral and does not apply to standard step-down applications. Refer to NEC 450-4 for overcurrent protection of an autotransformer. • • 7-24 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog • All applications are suitable for 60Hz only. 8SPEEDFAX TM 2007-2008 Power Monitoring Contents Power Monitoring Systems Overview 8-2 Intelligent Metering and Control Devices 8-3 9200 Power Meter 8-4 9300 Power Meters 8-5 9330/9350 Power Meters 8-6 9510/9610 Power Meters 8-7 9510 ADR Advanced Data Recorder 8-8 WinPM.Net Software 8-9 Current and Voltage Transformers 8-10 Application Engineering Services and Training 8-11 Siemens ACCESS power monitoring systems provide the hardware and software for complete power information management and control. Features ▪ Power Quality Reliability and Analysis ▪ Electrical Asset Management ▪ Utilities Cost Allocation and Billing ▪ Utilities Usage Aggregation ▪ Load Studies and Circuit Optimization ▪ Demand and Power Factor Control ▪ Load Preservation ▪ Equipment Monitoring and Control For technical assistance contact: 1-800-427-2256 Email your questions: Access.Support@siemens.com For latest information go to: www.sea.siemens.com/ACCESS Residential Commercial Industrial POWER MONITORING ▪ Sequence of Events Recording ▪ Preventative Maintenance 8 ▪ JCAHO Compliance Testing ▪ Facility Monitoring and Automation Totally Integrated Power System Overview General 2 2 2 3 7 7 10 11 1 4 9 6 10 1 1 2 4 8 9 7 1 2 6 10 4 6 10 7 2 7 7 1 1 2 7 10 11 2 11 1 7 2 6 2 3 1 6 4 2 6 10 9 4 7 2 11 7 2 3 5 11 POWER MONITORING 8 2 3 7 10 11 1 2 7 1. Power Meters Siemens’ ACCESS power monitors combine the best of new technologies and proven practices. Monitor critical loads, power quality, and demand via the web directly from the meters. 2. Power Monitoring Software WinPM.Net web-enabled software facilitates easy, enterprise-wide connection to power monitoring equipment, circuit breakers, and other devices from Siemens and third parties. Access information via the web with unlimited no-cost clients using built-in WebReachTM via your web browser. 3. Communications Networks Utilize existing Ethernet or RS-485 communications networks to extract the information you need and get it where it needs to go. 4. Components Current Transformers (CTs), Voltage/Potential Transformers (PTs), Power Supplies, Ethernet Switches, Protocol Converters. Siemens can provide everything required for your system. 5. Intelligent I/O Our S7 I/O enables plug-n-play communications with Modbus devices and expands digital and analog input and output functionality of ACCESS Systems. 6. Billing and Load Allocation Software ACCESS Energy Manager is the low-cost, simplified solution for cost allocation, billing & load/demand analysis using your web browser. 8-2 3 8 4 5 9 10 11 7. Engineering Services PDS Application Engineers can help from design through commissioning of even the most demanding power quality and monitoring systems. 8. Motor Control Centers Monitor mains and feeders for critical or power-intensive loads. Communicate with breakers (Static Trip III, SBEC), SAMMS, SIMOCODE, I/O and devices from other manufacturers. Use ACCESS power meters to web-enable new as well as existing MCCs. 9. Low & Medium Voltage Switchgear Web-enable switchgear by having ACCESS monitor power as well as breaker status and upload the information to a corporate Intranet or to the Internet. Use MeterMailTM directly from meters for alarm conditions or simple reporting. 10. Facility Management Systems Tie into building automation systems to provide the required power and energy information. Lots of communications options are available ranging from legacy protocols to XML directly from the power monitors. 11. Distributed Control Systems, Automation, and SCADA/Human Machine Interface ACCESS power monitors and/or software can talk to all major vendors’ systems. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Totally Integrated Power Intelligent Metering and Control Devices 9100 POWER, ENERGY and DEMAND Voltage/current: per phase, average Voltage/current: unbalance Power: real, reactive, apparent, power factor, frequency Energy: bi-directional, import, export Energy: total, net Demand: block, sliding window Demand: thermal predicted POWER QUALITY ANALYSIS Sag/swell monitoring Symmetrical components: zero, negative, positive Transient detection, microseconds Harmonics (individual, even, odd, total) up to Sampling rate, maximum samples/cycle Flicker, harmonics to EN50160, IEC 6100-4-7 / 4-15 Configurable for IEEE 519-1992, IEEE 1159, SEMI/ITIC “Number of nines” uptime data (3 nines=99.9%) DATA and WAVEFORM LOGS Triggered by setpoint, schedule, or external signal Sequence-of-event logs, variable log depth Minimum/maximum logs for any parameter Historical logs, maximum # of channels Waveform logs, maximum # of consecutive cycles Time-stamps, resolution in seconds GPS time synchronization COMMUNICATION PORTS and I/O ( ) = Optional RS-232/485 ports RS-485-only ports Ethernet ports Infrared optical ports WirelessTransmission PROFIBUS ports Built-in modems kW/kWh General 9200 9300 9330 9350 • • • • • • • • • • • • • • • • • • THD only 64 15th 32 15th 32 9510 9610/9610H • • • • • • • • • • • • • • • • • • • • • • • • • 31st 64 63rd 256 65/17 127th/256th 512/1024 • • • • • • • • • • 800 800 96 0.001 800 96 0.001 • • • • • • • • • 1 32 • 0.001 96 48 0.001 1 1 (1) 1 9510 ADR 2 (1) 1 2 (1) 1 1 1 (1) 1 1 1 (1) 1 1 1 (1) 1 • (1) Modbus RTU Slave on serial, modem or infrared ports (If equipped with modem or infrared port) • (1) (1) (1) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • (4) (4) 4 4 (4) (4) 4 4 (4) (4) 8/8 7 (4) (4) 8/8 7 (4) (4) 8/8 7 1 sec 1 sec • • • • • • • • • • • • • • • • • (4) (4) 2 • 4 • • • • • • ⁄2 cycle 1 • • • ⁄2 cycle 1 ⁄2 cycle 1 • • • • • • • • • • • • • • • • • • • • • • • • Some features are optional. Refer to datasheets for allowable port configurations. Products meet or exceed the accuracy requirements of the standards listed; due to form factors, not all ANSI/IEC compliance tests may apply. Some products certified by third-party laboratory. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 8-3 POWER MONITORING (1) • 8 Modbus RTU Master on serial ports Modbus/TCP on Ethernet ports DNP 3.0 on serial, modem, infrared ports EtherGate™: 31 other meters accessible via RS-485 ModemGate: 31 other meters accessible via RS-485 MeterM@il®: data e-mailed from meter WebMeter®: on-board web server XML Analog inputs Analog outputs Digital status/counter inputs (standard/optional add-ons) Digital relay outputs (control/pulse) SETPOINTS, ALARMING and CONTROL Setpoints, minimum response time Math, logic, trig, log, linearization formulas Single- and multi-condition alarms Call-out on alarm REVENUE METERING ANSI C12.16 accuracy compliant ANSI C12.20 0.2 compliant IEC 60687 0.2S compliant IEC 60687 accuracy class 0.5S compliant ANSI class 10 (5A nominal, 10A max) ANSI class 2, IEC 1/10 (1A nominal, 10A max) ANSI class 20, IEC 5/20 (5A nominal, 20A max) MV-90 on serial; Ethernet ports Time-of-use Transformer/line loss compensation (1) • Totally Integrated Power 9200 Power Meter Selection Standard Measurements Voltage (l-n), per phase, avg. Voltage (l-l), per phase, avg. Current, per phase, avg. Meter Options Features ▪ Use the 9200 Power Meter for basic metering applications, like sub-billing, cost allocation and tenant monitoring ▪ For use in Switchboards to replace multiple analog meters and rotary switches, with less space and wiring ▪ Choose between two mounting options, and one of three measurement packages. All units come standard with Modbus/RTU RS-485 communication. The 9200 with no display is excellent for low cost sub-metering applications in switchboards High Accuracy POWER MONITORING 8 Measurement Method and Accuracy ▪ 64 samples per cycle ▪ IEC 60687 class 0.5 accuracy ▪ 4 quadrant energy and demand ▪ Per phase voltage, current, peak current demand, watts, VARs, kWh, and more ▪ Neutral current, THD, frequency, power factor and more ▪ Revenue Accurate Enhanced Package #1 Includes standard measurements and adds: Energy,(kWh) Imported/Exported Total Power, (kW) Total Peak Power Demand (kW)* Current Demand, Avg + Per Phase Peak Current Demand, Avg + Per Phase Current, Neutral Frequency Power Factor, Total Enhanced Package #2 Includes all the preceding parameters and adds: Power, (kW) Per Phase* Power Factor, Per Phase Reactive Energy (KVARh) Import/Export* Apparent Energy, (kVAh)* Reactive Power, (kVAR) Per Phase & Total* Apparent Power, (kVA) Per Phase & Total* Reactive Power, (kVAR) Peak Demand* Apparent Power, (kVA) Peak Demand* THD Voltage & Current, Per Phase Energy, (kWh) Import/Export Per Phase* 9200 Meter Catalog Number Configuration Meter Catalog Number 9200 D D - 1 Z Z A Description Meter base unit and diplay optins • Integrated display unit with RS-485 and Modbus RTU communication D • Remote display unit with RS-485 and Modbus RTU communication R • Non-display unit with RS-485 and Modbus RTU communication T Metering Options • Configured for Volts and Amps per phase and avg. A • Configured for Volts and Amps per phase and avg. with Energy/Power, Frequency, PF (package #1) D • Configured for Volts and Amps per phase and avg. with Energy/Power, Frequency, PF, KVAR, kVA, andTHD (package #2) G Power Supply • 100-240 Vac / 110-300Vdc 1 • 435-530Vac 2 Building Management Interface • 20-60 Vdc 3 Pulse Output Option ▪ kWh and/or kVARh and/or kVAh pulsing ▪ Rated 100mA, 200 VAC/DC Digital Output System Integration Security Options for Revenue Metering Communications ▪ Industry standard protocol, Modbus RTU, for use with WinPM.Net™ software or any Modbus compatible system • Password Protected • None Z •Two optically isolated Form A outputs for kWh, kVAh or kVARh energy pulsing A Z Specials • None A Power Supply ▪ 100-240 VAC (50-60 Hz)/110-300 VDC ▪ 20-60 VDC (+/-10%) ▪ 480 VAC *Meets or exceeds IEC 60687 class 0.5 accuracy. **As represented in SPACE 2000. 8-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PDS Totally Integrated Power 9300/9330/9350 Low Cost Web-enabled Power Meter Use the 9300 Power Meter for basic metering applications, like sub-billing, cost allocation, tenant monitoring and for any PROFIBUS applications. Use the 9330 Power Meter where onboard data logging and setpoint-based alarms are required. An optional, built-in modem is available, and can be used as a gateway for up to 31 additional devices. Use the 9350 where -- in addition to all of the above -- waveforms are required. Also has sag/swell, enhanced harmonics, and faster sampling rates. All meters have the option of adding a network card which provides an Ethernet port and access to onboard web pages, for easy viewing of real-time data from your desktop browser. This also enables MeterMail, a function that allows the meters to send messages to PCs, pagers, cell phones, PDAs and other mobile devices. These messages can be alarms, data, peak demand notifications, etc. Selection ▪ 9350 SEAbus/ION, Modbus RTU & TCP, DNP3.0 ▪ EtherGate™ allows direct Ethernet-to RS-485 data transfer to 31 other devices ▪ Infrared data port standard Onboard Data Logging ▪ 9330 - Log up to 32 parameters for 30 days ▪ 9350 - Same as 9330 plus three6-channel waveform captures, fully configurable ▪ Sequence-of-events and min/max logging Setpoints for Control and Alarms ▪ Create custom set-points on any parameter or condition ▪ 1 second operation ▪ Control demand with peak shaving and advanced notification of approaching peaks 9300 Meter Catalog Number Configuration Description Meter base unit and diplay options • Meter with integrated display • Meter with remote display (includes 6' cable and surface mount transducer) • Meter without display (Surface mount transducer version) • Meter with integrated display installed in S1 retro-fit switchboard kit (meter in cage with cover, no casing) • Meter with integrated display installed in FT21 retro-fit switchboard kit (meter in cage with cover, no casing) Communicatons • RS485 with Modbus RTU (for use with integrated display only - when selecting “D” , “S” or “F” base unit above) • RS485 with Modbus RTU (for use with transducer version only - when selecting “T” or “R” base unit above) • Profibus (for use with integrated display model only - selection “D” above) Power Supply • 85-240 VAC/VDC • 20-60 VDC Input Voltage • 50-347 VAC Input Frequency • 50 - 60 Hz 0 - N Z Z Z A D R T S F C M P 1 2 0 0 Z N B C D E F G Wire Terminal Type for Input Voltage & Current Connections • Ring/Split/Bare wire type • Barrier/Captured wire type Meter Mounting Options • Standard panel mounting • DIN Rail Kit (available for Remote “R” orTransducer “T” type base units only) Tropicalization Protection • None •Yes Draw-Out Case Option Available in 9300, 9330 and 9350 meter styles Discount Schedule PDS Specials • None Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog POWER MONITORING Network Card or Analog I/O (Analog options not available with Profibus or Remote and Transducer base unit options) • None • Ethernet Communication (10BaseT) RJ-45 Port • 4 Analog Inputs 0 to 1 mA • 4 Analog Inputs 0 to 20 mA • 4 Analog Outputs 0 to 1 mA • 4 Analog Outputs 0 to 20 mA • 4 Analog Inputs 0 to 1 mA & 4 Analog Outputs 0 to 1 mA • 4 Analog Inputs 0 to 20 mA & 4 Analog Outputs 0 to 20 mA Meter Catalog Number 9300 D C - 1 0 8 Mounting Options: ▪ Integrated Display for panel mounting ▪ Remote Display ▪ No display ▪ In FT21 or S1 switchboard case for retrofit applications Measurements ▪ Hundreds of high accuracy power measurements ▪ Harmonics to the 15th for 9300 & 9330, to the 31st for the 9350 ▪ Predicted kW demand for demand control applications Digital Inputs and Outputs ▪ 4 digital inputs for status/counter functions, log gas, water, steam and air inputs ▪ 4 digital outputs for control/pulse Waveform Capture (9350 only) ▪ Capture from 12 to 48 cycles on all channels at 16 to 64 samples per cycle ▪ Sag/swell detection to trigger waveforms on out-of-tolerance conditions Analog Inputs and Outputs ▪ 4 - 4-20mA Inputs and Outputs ▪ 4 - 0-1mA Inputs and Outputs Communications ▪ 9300 single RS-485 port, Ethernet option ▪ 9330 two RS-485 ports std, Ethernet and Modem optional ▪ 9350 two RS-485 ports std, Ethernet and Modem optional Supported Protocols ▪ 9300 SEAbus/ION, PROFIBUS, Modbus RTU & TCP ▪ 9330 SEAbus/ION, Modbus RTU & TCP, DNP3.0 Z P Z D Z T A 8-5 Power Monitoring 9330/9350 Power Quality Meter with Web Server Technology 9330/9350 Meter Catalog Number Configuration Meter Catalog Number 9330 D C 9350 Description Meter base unit and diplay options • Meter with integrated display • Meter with remote display (includes 6' cable and surface mount transducer) T • Meter with integrated display installed in S1 retro-fit switchboard kit (meter in cage with cover, no casing) S • Meter with integrated display installed in FT21 retro-fit switchboard kit (meter in cage with cover, no casing) F • RS485 with Modbus RTU (for use with transducer version only - when selecting “T” or “R” base unit above) 1 0 0 - O Z Z Z Z A D R • Meter without display (Surface mount transducer version) Communications • RS485 with Modbus RTU (for use with integrated display only - when selecting “D” , “S” or “F” base unit above) - Selection C M Power Supply • 85-240 VAC/VDC • 20-60 VDC 1 2 Input Voltage • 50-347 VAC 0 Input Frequency • 50 - 60 Hz 0 Modem • None 0 • Modem w/ RJ-11 (See Note 1 below) • Modem w/ plug connector (See Note 1 below) 1 2 Network Card or Analog I/O (Analog options not available with Remote orTransducer base unit options) • None Z • Ethernet Communication (10BaseT) RJ-45 Port N • 4 Analog Inputs 0 to 1 mA B • 4 Analog Inputs 0 to 20 mA C • 4 Analog Outputs 0 to 1 mA D • 4 Analog Outputs 0 to 20 mA E • 4 Analog Inputs 0 to 1 mA & 4 Analog Outputs 0 to 1 mA F • 4 Analog Inputs 0 to 20 mA & 4 Analog Outputs 0 to 20 mA G POWER MONITORING 8 Wire Terminal Type for input voltage & current connections • Ring/Split/Bare wire type • Barrier/Captured wire type Meter Mounting Options • Standard panel mounting • DIN Rail Kit (available for Remote “R” or Transducer “T” type base units only) Tropicalization Protection • None • Yes Specials • None Z D Z T A Note 1 — The listed modems are suitable for USA applications. Contact Sales for special versions. 8-6 Z P Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Totally Integrated Power 9510/9610 Power Quality Meter with Web Server Technology 9510/9610 Power Meter ▪ 9610 SEAbus/ION, Modbus RTU & TCP, DNP3.0, XML ▪ EtherGate™ allows direct Ethernet-to RS-485 data transfer to 31 other devices ▪ ModemGate™ allows direct modem-to RS-485 data transfer to 31 other devices ▪ Infrared data port standard Modbus Master ▪ Bring other devices’ information into the meter using the Modbus Master capability. Store data onboard in the meter, display locally, create set-points for the logged values and perform logic functions. Web server posts slave device data to web pages Meter Catalog Number 9510 D C - 1 9610 9510/9610 Meter Catalog Number Configuration Description Meter base unit and diplay options • Meter with integrated display, and 5 MB logging memory • Meter with integrated display, and 10 MB logging memory • Meter without display, with 5 MB logging memory (Transducer version) • Meter without display, with 10 MB logging memory (Transducer version) 5 6 - A B Z Z A D D E T U Sampling Rate • 512 sampling C • 1024 Sampling H Power Supply • 85-240 Vac/Vdc • 20-60 Vdc 1 1 2 Input Voltage • 57 to 347 L-N / 100 to 600 L-L Vac 1 Input Current • 1A Nominal (10 Amp full scale) • 5A Nominal (20 Amp full scale) 1 5 System Frequency • 50 Hz 5 • 60 Hz 6 Ethernet Ethernet 10Base-T with RJ45 10Base-FL X X X X X X Auxiliary I/O Cards • Optiom #1 - None (base meter includes 8 digital in & 7 digital out) • Optiom #2 - 8 Binary Inputs; 4 Analog Inputs 0 to 1 mA • Optiom #3 - 8 Binary Inputs; 4 Analog Inputs 0 to 20 mA • Optiom #4 - 8 Binary Inputs; 4 Analog Outputs -1 to 1 mA • Optiom #5 - 8 Binary Inputs; 4 Analog Outputs 0 to 20 mA • Optiom #6 - 8 Binary Inputs; 4 Analog Inputs 0 to 20 mA & 4 Analog Outputs 0 to 20 mA • Optiom #7 - 8 Binary Inputs; 4 Analog Inputs 0 to 1 mA & 4 Analog Outputs -1 to 1 mA Tropicalization Protection • None •Yes Specials • Standard (password protected, no locking or sealing) • Password protected and hardware lockable (lock enabled/disabled via jumper on comm card) • EN50160 compliance monitoring • EN50160 compliance monitoring with password protection and hardware lockable A B C D E F POWER MONITORING Communication Cards RS232/RS485 Infrared Modem (Selectable) RS485 (Note 1) (Notes 1 & 2) X X X X X X X X X X X X X X X X X X X X X 8 Power Quality Meter with Web Server Technology ▪ Use the 9510 Power Quality Meter at service entrance points, on critical loads, and at locations requiring power quality analysis ▪ Use the 9610 Power Quality Meter to meet all the requirements above and where high-speed transient capture, additional memory for data logging and/or compliance monitoring is required ▪ Both meters have the option of adding a network card, which provides an Ethernet port and access to onboard web pages for easy viewing of real-time data from your desktop browser. Also includes e-mail for alarms as well as for sending scheduled data such as monthly kWh Mounting Options: ▪ Integrated Display for panel mounting ▪ Transducer (TRANS) with no display where local display is not required Measurements ▪ Hundreds of high accuracy power measurements ▪ Harmonics to the 127th for 9510, to the 511th for the 9610 ▪ Predicted kW demand for demand control applications Standard Digital Inputs and Outputs ▪ 8 digital inputs for status/counter functions. Log gas, water, steam, air inputs, breaker status, etc. ▪ 4 digital outputs for control/pulse ▪ 3 relay outputs for control Additional I/O ▪ 4 - 4-20mA Inputs and Outputs ▪ 4 - 0-1mA Inputs and Outputs ▪ 8 Digital Inputs Waveform Capture ▪ Capture from 7 to 96 cycles on all channels at 16 to 1024 samples per channel per cycle per event. Multiple events can be linked to form a continuous waveform strip chart ▪ 1 cycle Sag/swell detection to trigger waveforms on out-of-tolerance conditions Selection Transient Capture ▪ The 9610 can detect and record sub-cycle transients as short as 17 microseconds Communications ▪ 9510 two RS-485 ports standard, Ethernet and Modem optional ▪ 9610 two RS-485 ports standard, Ethernet and Modem optional ▪ Meter Mail allows e-mail of alarms or data logs by schedule or event driven Supported Protocols ▪ 9510 SEAbus/ION, Modbus RTU & TCP, DNP3.0, XML Z B C D E F G Z T A B C D Note 1 — The infrared and modem connections cannot be operated simultaneously. The connection type is configurable. Note 2 — The listed modems are suitable for European applications. Contact Sales for special versions. Discount Schedule PDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 8-7 Totally Integrated Power Critical Process Monitoring with the 9510/9610 Siemens Advanced Data Recorder (ADR) Selection Local Display for WL Power Breaker 9510 ADR 9510 ADR Wiring For use as a low-cost data concentrator or local display, the 9510 ADR is a multi-function device which supports multiple protocols, digital and I/O options, and customizable displays. Each unit must be custom configured for your application. Standard units are shipped with displays only for the digital I/O status. To use the unit as a Local Display, custom programming is required. ▪ Consolidate data from multiple devices in a central display. ▪ View real-time and breaker status for up to 16 WL breakers, with 20 points per trip unit. ▪ WL Breakers must include a COM 16 module for communication capability. Features: ▪ Monitor breaker status changes with 1ms resolution Collect, log and scale pulse inputs from water, ▪ air, gas, electricity or steam meters ▪ Act as an Ethernet Gateway for serial devices ▪ Display Modbus slave information locally and via HTML web pages ▪ Log data and e-mail alarms from Downstream Modbus devices ▪ Display trip unit data from WL, Static Trip III and SB-EC devices ▪ Trigger alarms based on setpoint conditions 9510 ADR Catalog Number Configuration Description Monitor Base Unit Type • Monitor with integrated display, and 5 MB logging memory • Monitor with integrated display, and 10 MB logging memory • Monitor without display, with 5 MB logging memory (Transducer version) • Monitor without display, with 10 MB logging memory (Transducer version) Communication • Modbus ▪ SPI-1000 is required for communication between 9510 ADR and Static Trip III. WL Trip Units (max 16 devices) Meter Catalog Number 9510 D C - 2 R 8 POWER MONITORING T U - B Z Z A D E T U C 1 2 Device • Remote Transducer Unit R T U 10Base-T with RJ45 10Base-FL X X X X X X Auxiliary I/O Cards • None (base meter includes 8 digital in & 7 digital out) • 8 Binary Inputs; 4 Analog Inputs 0 to 1 mA • 8 Binary Inputs; 4 Analog Inputs 0 to 20 mA • 8 Binary Inputs; 4 Analog Outputs -1 to 1 mA • 8 Binary Inputs; 4 Analog Outputs 0 to 20 mA • 8 Binary Inputs; 4 Analog Inputs 0 to 20 mA & 4 Analog Outputs 0 to 20 mA • 8 Binary Inputs; 4 Analog Inputs 0 to 1 mA & 4 Analog Outputs -1 to 1 mA Tropicalization Protection • None •Yes Specials • Standard (password protected, no locking or sealing) A B C D E F Z B C D E F G Z T A * Factory Programming Available (contact sales or refer to Engineering Service price list). 8-8 Water, Air, Gas and Steam Monitoring The Advanced data recorder comes with Digital inputs which can be configured for pulse counting applications where full utility monitoring is required. Now gas, water, air and steam pulses can be collected in one unit, logged and displayed. Up to 16 digital inputs can be added. Local Display Power Supply • 85-240 Vac/Vdc • 20-60 Vdc Communication Cards 5 Infrared Modem (Selectable) RS485 (Note 1) (Notes 1 & 2) X X X X X X X X X X X X X X X X X X X X X ▪ Factory configured and installed. ▪ View real-time and breaker status for up to 16 Static Trip III units, with 20 points per breaker. COM 1 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Totally Integrated Power WinPM.Net Software WinPM.Net ™ web-enabled software is a complete energy information management solution for your business. It offers control capabilities, comprehensive power quality and reliability analysis and can help you reduce energy related costs. WinPM.Net allows you to manage our intelligent metering, monitoring and control devices, analyze data, and decide on new courses of action. Its cutting-edge flexibility and compatibility means you can add one piece at a time, at your own pace, while still maintaining your original investments. Interface to your existing systems through industry-standard protocols and choose newer components as they become available. WinPM.Net is a powerful software suite that can process, analyze, store, and share data across your entire enterprise. You can access information from any desktop workstation, locally or around the world, in the format you need. The software collects data through serial, wireless, modem, or Ethernet links, so you can manage a single site or a global network of devices. Customized System Diagrams: ▪ Powerful Aggregation and control Tools ▪ All configuration tools are included as standard; no separate development/ runtime licenses WinPM.Net: for Analysis and Control: ▪ Display and Configuration ▪ Power Quality ▪ Cost Allocation ▪ Automated Control ▪ Logging Data from Devices ▪ Load Aggregation ▪ Modbus Master Applications: ▪ Power Quality and Reliability Analysis ▪ Cost Allocation and Billing ▪ Load Studies and Circuit Optimization ▪ Demand and Power Factor Control ▪ Equipment Monitoring and Control ▪ Preventative Maintenance WinPM.Net Data Analysis: ▪ Standard Reports ▪ Aggregate Energy and Demand Reports ▪ Aggregate Load Profile Reports ▪ Power Quality Reports ▪ EN50160 Reports • Custom Reports WinPM.Net Networks: ▪ Serial Sites ▪ Ethernet Sites ▪ Modem Sites ▪ Gateway Sites ▪ Web Deployment ▪ Time Synchronization ▪ Third Party Integration Custom Graphical Interface: ▪ Reporting & Visualization ▪ Device Configuration ▪ Firmware Upgrade Utility ▪ Configuration Tools WinPM.Net Monitoring Your Power System: ▪ Take Advantage of Default Views ▪ Power Quality Displays ▪ Customize Your Backgrounds ▪ Display Data the Way You Want ▪ Receive Alarms at Your Desktop or on Your Mobile Device (Pager, Cell phone, PDA, etc.) ▪ Access WinPM.Net Remotely from any Networked PC Using Web Browser (Internet Explorer). ▪ Perform Manual Control Operations ▪ Create Your Own Database Queries ▪ Check Status Indicators ▪ Generate Trend Graphs ▪ Tunnel into Details with “Hot Spots” ▪ Share data with other ODBC programs Ordering Information: WinPM.Net is packaged based on the number of devices (power monitors, circuit breakers, protective relays, etc.) that will be monitored. Consult factory for pricing and configuration recommendations. Start-up services are required for all software sales. Email: Access.Support@sea.siemens.com Toll-free: 1-800-427-2256 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 8-9 POWER MONITORING Features Summary: ▪ Unlimited no-cost view only clients using standard web browser ▪ Data Acquisition ▪ Monitoring ▪ ▪ ▪ ▪ 8 Device Compatibility WinPM.Net supports all current ACCESS field devices, including the following: ▪ 9700 Power Meter ▪ 9610 Power Meter ▪ 9510 Power Meter ▪ 9350 Power Meter ▪ 9330 Power Meter ▪ 9300 Power Meter ▪ 9200 Power Meter ▪ 4720 Power Meter ▪ 4700 Power Meter ▪ 4300 Power Meter ▪ ISGS intelligent Switchgear System ▪ SB Energy Communicating Breaker Unit (SBEC) ▪ WL/VL Low Voltage Power Circuit Breakers ▪ Static trip III Trip Unit ▪ S7 I/O ▪ Siemens Advanced Motor Master System (SAMMS) ▪ ISGS MV Relays ▪ Most third party Modbus Devices General Analysis Control Equipment Monitoring and Control Preventative Maintenance Totally Integrated Power Current & Voltage Transformers (Metering Grade) Selection Low Voltage Current Transformers (Metering Grade) Primary Description Secondary Accuracy POWER MONITORING 8 Split Core - Rectangular Metering Grade, 600V, 0.5% Accuracy 100A 1.25" x 1.51" Window 5A Output 200A 1.25" x 1.51" Window 5A Output 300A 1.25" x 1.51" Window 5A Output 400A 2.45" x 2.89" Window 5A Output 600A 2.45" x 2.89" Window 5A Output 800A 2.45" x 2.89" Window 5A Output 1000A 2.45" x 5.50" Window 5A Output 1200A 2.45" x 5.50" Window 5A Output 1600A 2.45" x 5.50" Window 5A Output 2000A 2.75" x 6.625" Window 5A Output 3000A 2.75" x 6.625" Window 5A Output Split Core - Round Metering Grade, 600V 200A 4.0" Window 5A Output 4% Accuracy 300A 4.0" Window 5A Output 4% Accuracy 400A 4.0" Window 5A Output 3% Accuracy 600A 4.0" Window 5A Output 2% Accuracy 800A 4.0" Window 5A Output 2% Accuracy 1200A 4.0" Window 5A Output 2% Accuracy 3000A 6.0" Window 5A Output 2% Accuracy 2000A 6.0" Window 5A Output 2% Accuracy 4000A 6.0" Window 5A Output 2% Accuracy Solid Core - Round Metering Grade, 600V, 0.3 % Accuracy 200A 1.25" Window 5A Output 300A 1.25" Window 5A Output 400A 1.25" Window 5A Output 500A 1.25" Window 5A Output 600A 1.25" Window 5A Output 800A 1.25" Window 5A Output 1000A 1.25" Window 5A Output 100A 2.25" Window 5A Output 200A 2.25" Window 5A Output 300A 2.25" Window 5A Output 400A 2.25" Window 5A Output 800A 4.0" Window 5A Output 1000A 4.0" Window 5A Output 1200A 4.0" Window 5A Output 1600A 4.0" Window 5A Output 2000A 4.0" Window 5A Output 3200A 6.5" Window 5A Output 4000A 6.5" Window 5A Output Solid Core - Round Metering Grade, 600V, 0.3 % Accuracy 100A 1.75" x 2.47", 1" Window 5A Output 200A 1.75" x 2.47", 1" Window 5A Output 250A 1.75" x 2.47", 1" Window 5A Output 300A 1.75" x 2.47", 1" Window 5A Output 400A 1.1" x 3.56", 1.56" Window 5A Output 600A 1.1" x 3.56", 1.56" Window 5A Output 800A 1.1" x 3.56", 1.56" Window 5A Output 1000A 1.1" x 3.56", 1.56" Window 5A Output 2000A 1.15" x 5.73", 3.25" Window 5A Output 2500A 1.15" x 5.73", 3.25" Window 5A Output 3000A 1.15" x 5.73", 3.25" Window 5A Output 4000A 1.15" x 5.73", 3.25" Window 5A Output Catalog Number PDS-CTSC-011 PDS-CTSC-021 PDS-CTSC-031 PDS-CTSC-042 PDS-CTSC-062 PDS-CTSC-082 PDS-CTSC-013 PDS-CTSC-123 PDS-CTSC-163 PDS-CTSC-02R PDS-CTSC-03R PDS-CTHC-024 PDS-CTHC-034 PDS-CTHC-044 PDS-CTHC-064 PDS-CTHC-084 PDS-CTHC-124 PDS-CTHC-306 PDS-CTHC-206 PDS-CTHC-406 PDS-CTRC-021 PDS-CTRC-031 PDS-CTRC-041 PDS-CTRC-051 PDS-CTRC-061 PDS-CTRC-081 PDS-CTRC-101 PDS-CTRC-012 PDS-CTRC-022 PDS-CTRC-032 PDS-CTRC-042 PDS-CTRC-084 PDS-CTRC-104 PDS-CTRC-124 PDS-CTRC-164 PDS-CTRC-204 PDS-CTRC-326 PDS-CTRC-426 SMU-CT-011 SMU-CT-021 SMU-CT-025 SMU-CT-031 SMU-CT-041 SMU-CT-061 SMU-CT-081 SMU-CT-123 SMU-CT-02R SMU-CT-25R SMU-CT-30R SMU-CT-40R Voltage Transformers - Metering Grade, 600V and 5KV, +/- 1% Accuracy at all burdens up to 5VA at 1.0 and .95 pf 8-10 Catalog Number Description Primary Secondary 467-480 467-288 PTW3-2-60-242 PTW5-2-110-722 Potential Transformer (4:1) Potential Transformer,277:120V L-N 2.4:1 Potential Transformer, 2 BUSHINGS, NO FUSES Potential Transformer, 2 BUSHINGS, NO FUSES 480 V 277 V 2400 V 7200 V 120 V 120 V 120 V 120 V Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Totally Integrated Power Application Engineering Services & Training General Training Center in Norcross, Georgia Siemens’ Power Distribution Solutions group can provide engineered solutions, not just great products. Siemens PDS Application Engineers are power monitoring experts experienced in all industrial and commercial power applications. Our engineers are the best qualified to ensure that power monitoring systems are properly installed and commissioned. For your specific needs, please consult factory. Additionally, integration into Eaton/CutlerHammer, Square D PowerLogic, General Electric, Rockwell, PML and many other systems can be accomplished in a number of ways. Please give us a call to discuss our specific requirements. POWER MONITORING Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 8 Here is a brief summary of what we do: ▪ Power Quality & Reliability Analysis ▪ Utilities Cost Allocation and Billing ▪ Load Studies & Circuit Optimization ▪ Demand & Power Factor Control ▪ Equipment Monitoring & Control ▪ Preventative Maintenance & Reporting ▪ Design, Start-up & Commissioning ▪ Factory certify power monitoring system operation ▪ System drawings and device documentation ▪ Optimally configure each power monitoring device (set-up, data logging, communications, event-capture, customized web-server pages, etc.) ▪ Workstation software setup and configuration ▪ Other customized work per customer requirements (custom screen configuration, networks, alarming, etc.) ▪ Technical support ▪ Overview and thorough “hands-on” operator training on their own systems ▪ Additional, higher-level training can be tailored to suit individual customer needs at Siemens’ training facility in Norcross, GA or on-site 8-11 POWER MONITORING 8 Notes 8-12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 9SPEEDFAX TM 2007-2008 TVSS Contents TPS General Information (For Internal Equipment Mounted, Consult Factory) 9-2 External or Remote Mounted Unit Selection TPS 9, TPS 10 9-3 – 9-4 TPS 11, TPS 12 and TPS 16 9-5 – 9-7 9 TVSS Residential Commercial Industrial TVSS - Transient Voltage Surge Suppressors TPS - Transient Protection System Siemens offers surge suppression products to provide for multi–stage protection. Why have multi-stage protection? High voltage surges enter your systems as the result of utility switching, lightning strikes and low voltage transients caused by internal equipment such as motors and compressors. All of these surges can destroy sensitive electronic equipment. The Siemens TPS system has products to fit at every level of the electrical distribution system. INTEGRAL Factory Installed Option ▪ Pre-wired and Protection Ready ▪ Priced & Configured with Specified Gear ▪ Field Replaceable Design ▪ UL Listed Contact Factory for More Information and Current Specifications. Lighting Panel Mounted Units - P1, P2 & P3 TVSS 9 TPS 1 Standard Features: ▪ Retrofit capabilities ▪ Direct Bus Connection ▪ 120kA, 160kA & 240kA ▪ LED Indication, Audible Alarm & Dry Contacts ▪ All Modes of Protection Surge Counter & Remote Monitor Options. TPS 1 (SAD & SAD/MOV Hybrid) Standard Features: ▪ Retrofit capabilities ▪ Direct Bus Connection ▪ 20kA, 90kA, 130kA & 170kA ▪ LED Indication, Audible Alarm & Dry Contacts ▪ All Modes of Protection Surge Counter & Remote Monitor Options. TPS 11 Standard Features: ▪ Breaker Fed (30-50 amp) ▪ 120kA & 160kA (voltage sensitive) 9-2 ▪ LED Indication, Audible Alarm & Dry Contacts ▪ All Modes of Protection Surge Counter & Remote Monitor Options. TPS 9 Standard Features: ▪ Breaker Fed (20 amp) ▪ 80kA & 100kA ▪ LED Indication Distribution Panel and Distribution Section Switchboard Mounted Unites P4 and P5 and front connected distribution section switchboard applications TPS 5 Standard Features: ▪ Close Connection to Panel Bus ▪ 160kA & 240kA ▪ LED Indication, Audible Alarm & Dry Contacts ▪ Integral Disconnect Switch ▪ All Modes of Protection Surge Counter & Remote Monitor Options. Service Section and Switchgear Mounted Units - S1, S2, S3 or RCIII Switchboards TPS 6 Standard Features: ▪ Mounted in Customer Instrument Compartment ▪ 240kA, 320kA & 400kA ▪ LED Indication, Audible Alarm & Dry Contacts ▪ Integral Disconnect Switch ▪ All Modes of Protection Surge Counter & Remote Monitor Options. Motor Control Mounted Units - 6 inch and 18 inch MCC Bucket Applications TPS MCC Standard Features: ▪ 6" Compact Design Installed in a Section ▪ 160kA & 240kA ▪ Racking Lever Disconnect ▪ Audible Alarm ▪ Modular EXTERNAL For Remote Wall Mounting Applications ▪ Factory Quick Ship ▪ Fully Assembled ▪ EMI / RFI Filtering ▪ UL Listed Contact Factory for More Information and Current Specifications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog General TPS 9 Close Coupling to Distribution Equipment Standard Features: ▪ Breaker Fed (20 amp) ▪ 80kA, 100kA, 120kA & 150kA (voltage sensitive) ▪ LED Indication ▪ NEMA 4X Enclosure Flush Mounting Option. TPS 10 Close Coupling to Distribution Equipment Standard Features: ▪ Breaker Fed (30-50 amp) ▪ 50kA ▪ LED Indication ▪ NEMA 4X Enclosure ▪ All Modes of Protection Audible Alarm, Dry Contacts, Remote Monitor & Flush Mounting Options. TPS 11 Close Coupling to Distribution Equipment Standard Features: ▪ Breaker Fed (30-50 amp) ▪ 80kA, 120kA & 160kA (voltage sensitive) ▪ LED Indication ▪ NEMA 4X Enclosure ▪ All Modes of Protection Audible Alarm, Dry Contacts, Remote Monitor & Flush Mounting Options. TPS 12 Close Coupling to Service Entrance and Distribution Equipment Standard Features: ▪ Breaker Fed (30-50 amp) ▪ 80kA, 120kA & 160kA (voltage sensitive) ▪ LED Indication ▪ NEMA 4X Enclosure ▪ All Modes of Protection Internal Disconnect Switch, Surge Counter, Dual Surge Counter, Remote Monitor, 3, 4, 4X & Flush Mounting Options. TPS 16 Close Coupling to Distribution Equipment Standard Features: ▪ Breaker Fed (30-50 amp) ▪ 120kA, 180kA & 240kA ▪ 10 - Mode Protection Design ▪ NEMA 4X Enclosure Dry Contacts, Surge Counter, Audible Alarm, & Remote Monitor Options. TVSS - Transient Voltage Surge Suppressors TPS 9 - Transient Protection System Selection TPS 9 Transient Protection System for Sensitive Electronic loads. Externally mounted to Electrical Distribution Equipment. FEATURES ▪ UL 1449 Second Edition Revision effective Feb. 9, 2007 (aka UL 1449 Rev 2.5). Designed and tested in accordance with IEEE C62.41.1, C62.41.2, and C62.45 ▪ UL 1449 Rev 2.5 listed for 200kA SCCR applications or below. In compliance with NEC Article 285.6 ▪ Modes of protection: L-N, L-G, and L-L ▪ Multistage protection circuit ▪ Fast acting 20mm MOV’s ▪ NEMA4X Standard Enclosure ▪ LED indicators for immediate status monitoring ▪ Dimensions: 8" x 3" x 3" ▪ Weight: 4 lbs. AVAILABLE OPTIONS ▪ Flush Mount ORDERING INFORMATION Catalog# TPS 09 Voltage Code A = 120/240V 1Ø 3W B = 240/120V 3Ø 4W C = 208Y/120V 3Ø 4W D = 240V 3Ø 3W E = 480Y/277V 3Ø 4W F = 480V 3Ø 3W K = 380Y/220V 3Ø 4W Surge Current (kA) 080 100 120** 150** Options (*) L = Remote LED D = Dry Contact F = Flush Mount N = Noise Filter T = Adds N-G (Gas Tube) 9 * When an option is not selected, include a zero (0) in the option field **Only for voltage codes A and C TVSS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 9-3 TVSS - Transient Voltage Surge Suppressors TPS - Transient Protection System Selection TPS 10 Transient Protection System for Sensitive Electronic loads. Externally mounted to Electrical Distribution Equipment. FEATURES ▪ UL 1449 Second Edition Revision effective Feb. 9, 2007 (aka UL 1449 Rev 2.5). Designed and tested in accordance with IEEE C62.41.1, C62.41.2, and C62.45 ▪ Patented TranSafe™ Circuitry Design incorporating thermal cutouts and surge rated fuses ▪ UL 1449 Rev 2.5 listed for 200kA SCCR applications or below. In compliance with NEC Article 285.6 ▪ All modes of protection: L-N, L-G, L-L, & N-G ▪ Multistage protection circuit ▪ Fast acting 20mm MOV’s ▪ NEMA 4X Standard Enclosure ▪ LED indicators for immediate status monitoring ▪ Dimensions: 6" x 6" x 4" ▪ Weight: 8 lbs. AVAILABLE OPTIONS ▪ ▪ ▪ ▪ Audible Alarm Dry Contacts Flush Mount Remote Monitor ORDERING INFORMATION TVSS 9 Catalog# TPS 10050 Voltage Code A = 120/240V 1Ø 3W B = 240/120V 3Ø 4W C = 208Y/120V 3Ø 4W E = 480Y/277V 3Ø 4W Options (*) R = Remote Monitor D = Dry Contacts F = Flush Mount A = Audible Alarm * When an option is not selected, include a zero (0) in the option field 9-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog TVSS - Transient Voltage Surge Suppressors TPS - Transient Protection System Selection TPS 11 Transient Protection System for Sensitive Electronic loads. Externally mounted to Electrical Distribution Equipment. FEATURES ▪ UL 1449 Second Edition Revision effective Feb. 9, 2007 (aka UL 1449 Rev 2.5). Designed and tested in accordance with IEEE C62.41.1, C62.41.2, and C62.45 ▪ Patented TranSafe™ Circuitry Design incorporating thermal cutouts and surge rated fuses ▪▪ UL 1449 Rev 2.5 listed for 200kA SCCR applications or below. In compliance with NEC Article 285.6 ▪ All modes of protection: L-N, L-G, L-L, & N-G ▪ Multistage protection circuit ▪ Fast acting 20mm MOV’s ▪ NEMA4X Standard Enclosure ▪ LED indicators for immediate status monitoring ▪ Dimensions: 6" x 6" x 4" ▪ Weight : 8 lbs. AVAILABLE OPTIONS ▪ ▪ ▪ ▪ Audible Alarm Dry Contacts Flush Mount Remote Monitor ORDERING INFORMATION Catalog# TPS 11 Surge Current (kA) 080 120** 160*** Options (*) R = Remote Monitor D = Dry Contacts F = Flush Mount A = Audible Alarm 9 TVSS Voltage Code A = 120/240V 1Ø 3W B = 240/120V 3Ø 4W C = 208Y/120V 3Ø 4W D = 240V 3Ø 4W E = 480Y/277V 3Ø 4W F = 480V 3Ø 3W G = 600V 3Ø 3W K = 380Y/220V 3Ø 4W L = 600Y/347V 3Ø 4W *When an option is not selected, include a zero (0) in the option field ** Only for voltage codes A, B, C, E, K and L *** Only for voltage codes A, B, C, E and K Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 9-5 TVSS - Transient Voltage Surge Suppressors TPS - Transient Protection System Selection TPS 12 Transient Protection System for Sensitive Electronic loads. Externally mounted to Electrical Distribution Equipment. FEATURES ▪ UL 1449 Second Edition Revision effective Feb. 9, 2007 (aka UL 1449 Rev 2.5). Designed and tested in accordance with IEEE C62.41.1, C62.41.2, and C62.45 ▪ Patented TranSafe™ Circuitry Design incorporating thermal cutouts and surge rated fuses ▪ UL 1449 Rev 2.5 listed for 200kA SCCR applications or below. In compliance with NEC Article 285.6 ▪ All modes of protection: L-N, L-G, L-L, & N-G ▪ Multistage protection circuit ▪ Fast acting 40mm MOV’s ▪ Standard monitoring: LED Indicators, Audible Alarm, and Dry Contacts NEMA 12 Standard Enclosure: ▪ Standard 10" x 10" x 5" W/Disconnect 12" x 12" x 5" Flushmount 12" x 12" x 6" Weight 21 lbs. AVAILABLE OPTIONS ▪ ▪ ▪ ▪ Surge Counter ▪ Internal Disconnect Remote Monitor ▪ NEMA3R, 4, and 4X (may increase Flush Mount enclosure size) Dual Surge Counter ORDERING INFORMATION TVSS 9 Catalog# TPS 12 Voltage Code A = 120/240V 1Ø 3W B = 240/120V 3Ø 4W C = 208Y/120V 3Ø 4W D = 240V 3Ø 3W E = 480Y/277V 3Ø 4W F = 480V 3Ø 3W G = 600V 3Ø 3W K = 380Y/220V 3Ø 4W L = 600Y/347V 3Ø 4W Surge Current (kA) 120 160 240 *When an option is not selected, include a zero (0) in the option field 9-6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Options (*) R = Remote Monitor D = Disconnect 03 = NEMA 3R 04 = NEMA 4 4X = NEMA 4X F = Flush Mount S = Surge Counter 2 = Dual Counter TVSS - Transient Voltage Surge Suppressors TPS - Transient Protection System Selection TPS 16 Discrete 10-Mode Transient Protection System for Sensitive Electronic loads. Externally mounted to Electrical Distribution Equipment. FEATURES ▪ UL 1449 Second Edition Revision effective Feb. 9, 2007 (aka UL 1449 Rev 2.5). Designed and tested in accordance with IEEE C62.41.1, C62.41.2, and C62.45 ▪ Patented TranSafe™ Circuitry Design incorporating thermal cutouts and surge rated fuses ▪ UL 1449 Rev 2.5 listed for 200kA SCCR applications or below. In compliance with NEC Article 285.6 ▪ All modes of protection: L-N, L-G, L-L, & N-G ▪ Multistage protection circuit ▪ Fast acting 20mm MOV’s ▪ Standard monitoring: LED Indicators for immediate status monitoring, Red Service LED ▪ NEMA 4X Standard Enclosure: Standard 10" x 8" x 6" Weight 15 lbs. AVAILABLE OPTIONS ▪ Remote Monitor ▪ Dry Contact ▪ Surge Counter ▪ Audible Alarm ORDERING INFORMATION Catalog# TPS 16 Options (*) R = Remote Monitor D = Dry Contact S = Surge Counter (& Switched Audible Alarm) A = Audible Alarm TVSS Surge Current (kA) 120 180 240 9 Voltage Code A = 120/240V 1Ø 3W B = 240/120V 3Ø 4W C = 208Y/120V 3Ø 4W E = 480Y/277V 3Ø 4W K = 380Y/220V 3Ø 4W *When an option is not selected, include a zero (0) in the option field Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 9-7 TVSS 9 Notes 9-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10SPEEDFAX TM 2007-2008 Panelboards Contents PANELBOARDS Residential Commercial Industrial 10-2 – 10-8 10-9 – 10-14 10-15 10-16 10-17 – 10-22 10-17 10-18 10-19 10-20 – 10-21 10-22 10-23 – 10-32 10-23 10-24 10-25 10-26 10-27 10-28 – 10-31 10-32 10-33 – 10-43 10-33 10-34 10-35 – 10-36 10-37 – 10-38 10-39 – 10-42 10-43 10-44 – 10-54 10-44 10-44 – 10-46 10-47 10-48 10-49 – 10-50 10-51 – 10-53 10-54 10-55 – 10-65 10-55 10-56 10-57 10-58 10-59 10-60 10-61 – 10-64 10-65 10-66 – 10-69 10-70 10-71 – 10-73 10-71 10-71 10-72 10-73 10 Features, Reference Guide & General Specifications Unassembled Panelboards Factory Assembled Panelboard Coding System Factory Assembled Panelboard Pricing Type P1 Specifications Main Lug and Main Breaker Branch and Subfeed Breakers Modifications and Additions Enclosure Dimensions Type P2 Specifications Enclosure Selection Alternate Main and Subfeed Breakers Branch Breakers Main Lug and Main Breaker Modifications and Additions Enclosure Dimensions Type P3 Specifications Enclosure Selection Alternate Main, Branch and Subfeed Breakers Main Lug and Main Breaker Modifications and Additions Enclosure Dimensions Type P4 Specifications Enclosure Selection Main Lug and Main Breaker Main Switch and Alternate Main Breakers Branch Devices – Circuit Breaker and Switch Modifications and Additions Enclosure Dimensions Type P5 Specifications Enclosure Selection Main Lug and Main Breaker Alternate Main Breaker and Main Switch Branch Breakers Branch Switches Modifications and Additions Enclosure Dimensions Column Type Panelboards Telephone and Equipment Cabinets Panelboard Modifications and Additions Enclosures—Relay Cabinets, NEMA 4X Remote Switches—ASCO, LEN Circuit Breaker Modifications, Obsolete Kits Circuit Breaker Accessories & Panel Skirts Panelboards Introduction General Features Overview The new generation of products from an outstanding ancestry represents the high level of engineering innovation expected from Siemens. Additional strength has been added to an already rugged and durable panelboard family. This product has added flexibility and is easier to install. These newer designs also simplify wiring and reduce material requirements, saving additional installation time. those tight areas, the P3 panel packs the power of a distribution panel. The newly defined “P Series” of panels offer a stepped approach to power distribution. Anchored at one end with the innovative P1 that offers the industries most flexible designs to virtually eliminate the impact of common mistakes like feed direction, main lug versus main breaker. Adding distribution is also easy with the ability to add feed-thru lugs. With a minimum number of enclosures (six sizes), the P1 fits the majority of the lighting panel needs in a cost-effective package. Siemens also offers a number of specialty panels like column panels. Don’t see your requirement met? Ask a Siemens representative to tell you about our custom capabilities. The next step in the series and with subsequent steps, offers increased capacity and options. The P2 offers maximum flexibility and options to fit the most demanding specifications. The P3 is another flexible and innovative panel. Sized more like a lighting panel for The P4 offers a mid-sized distribution panel and allows fusible as well as circuit breaker branch and main devices. The P5 anchors the other end of the series. Larger fusible and circuit breaker branch and main devices give maximum power to the distribution system. Siemens offers a complete line of lighting, and power distribution panelboards. At the heart of the product line is the extensive research and technology found among Siemens circuit protection devices – both fusible switches and molded case circuit breakers. The lighting panel design still features the Fas-Latch trim that is popular with installers, the jacking screw system that permits adjustments even after wiring has been installed, and other features such as exclusive split neutral. Many panelboards have the capability of mixing and matching breakers of different sizes and ratings – or changing from main lug to main breaker, or adding subfeed breakers without changing box size. Other models accept a wide range of fuse types, including Siemens exclusive Vacu-Break® technology. Key Panelboard Features P1 P2 P3 P4 P5 Lighting And Appliance Applications • Power Panelboard Applications — • • • • • • • • Convertible From Top Feed To Bottom Feed Or Vice Versa • — — — — • — — — — Up To 250 Amps • • • • • • • • • Change From Main Lug To Main Breaker Or Add Subfeed Without Changing Enclosure Size Space-Saving, Horizontally Mounted Main Breaker • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • — — • • • • • • • • • Up To 250 Amps Up To 250 Amps Short-Circuit Rating Label Giving Performance Level Standard Aluminum Ground Assembly Blank End-Walls Standard Bolted Current-Carrying Parts Split Neutral Connection Accessible From Front Screw-Type Mechanical Lugs Time-Reducing Wing Nuts To Secure Interior Without Tools Main and Branch Devices Connected With Case-Hardened Hardware Flush Lock, Concealed Door Hinges/Trim Screws — — — • • • 5.75" 5.75" 7.75" 10.00" 12.75" 10 Accepts A Wide Range Of Fuse Types — — — Accepts Vacu-Break Fusible Switch — — — PANELBOARDS Symmetrical Interior Mounting Studs To Eliminate Upside-Down Mounting of Box Accepts A Wide Range Of Circuit Breakers — Accepts ACCESS™ Communications Tie-In — Optional Compression Lugs • • • • • • • • • • • • • • • • • Interior Height Adjustment For Flush Applications Mix and Match Fusible Switch Circuit Breaker Capability Shallow Depth (Standard) Panelboards • Standard KOs available on P1 and P2 — 5.75" deep X 20" wide boxes and P3 7.75" deep X 24" wide boxes. 10-2 equipped with Siemens Sensitrip® circuit breakers or Power Meters can be integrated into Siemens ACCESS™ electrical monitoring systems. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Panelboards Features / Benefits Reference The standard Siemens P1 panelboard has some unique features that make it easier to design for an engineer, easier to reconfigure in the field for a contractor, and easier to upgrade and maintain for the Owner. The P1 is the smallest panel in the Siemens lineup, with bus sizes up to 400A. What makes it different is it’s split neutral design and it’s open ended bus. In the Siemens panel, instead of the common single neutral bus on one end, we have a neutral bus on both sides that is cross-bussed. This makes branch wiring simpler and cleaner – the lead lengths for line and neutral can now be made the same, creating more room and a neater installation. It also allows access to both ends of the bus as a standard feature – this provides the flexibility to make changes in the field, even if it wasn’t part of the original configuration. MAIN BREAKER or SUB-FEED BREAKER MAIN LUGS or FEED-THROUGH LUGS INTEGRAL BUS MOUNTED TVSS The following can be done to a standard P1 panelboard in the field with no modifications: Change from top fed to bottom fed Add feed-through lugs Add an Integral bus-mounted TVSS Add a sub feed breaker up to 250 amps Change from Main Lugs to Main Breaker Change from Main Breaker to Main Lugs Panel may have up to two ground assemblies. Options are standard aluminum, copper, insulated or isolated aluminum or copper. Mounting provisions in opposing corners of the box are standard. Any of these options may be added after installation. PANELBOARDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10 ▪ ▪ ▪ ▪ ▪ ▪ ▪ 10-3 Panelboards Trim Options Standard Trim (FAS-Latch) PANELBOARDS 10 Door in Door Front Hinged Front 10-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Panelboards Special Enclosures Options NEMA 3R Enclosures NEMA 4X Enclosures Panel Family Portrait 10 PANELBOARDS “P” Series Panelboard Family for Lighting and Appliance and Distribution Panel Applications Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-5 Panelboards PANELBOARDS 10 General Specifications Class CTL Panelboards Class CTL panelboards incorporate physical features which, in conjunction with the physical size, configuration, or other means provided in Class CTL circuit breakers, are designed to prevent the installation of more over current protective poles than that number for which the device is designed and rated, per UL 67 and National Electrical Code (NEC) NFPA70. Service Entrance Equipment When a panelboard is used as service entrance equipment, it must be located near the point of entrance of building supply conductors. In a main lugs only panel, the number of breakers or switches directly connected to the main bus must be limited to six. In a panel having a main breaker or main switch, the number of circuits are not limited except as may be provided under other panelboard requirements, i.e., lighting and appliance branch circuit panelboards. Also, panels must include a connector for bonding and grounding neutral conductor. Panelboard Code Data 42-Circuit Rule: NEC Paragraph 408.34 defines a lighting and appliance branch circuit panelboard as one having more than 10 percent of its over current devices rated 30 amperes or less, for which neutral connectors are provided. NEC paragraph 408.35 states that not more than 42 over current devices (other than those provided in the mains) of a lighting and appliance branch-circuit panelboard shall be installed in any one cabinet. For the purpose of this article, a two pole circuit breaker shall be considered two over current devices; a three pole circuit breaker shall be considered three over current devices. (NEC 408.34 and 408.35 do not apply to panelboards feeding and communication circuits. Panelboards for this application must be so marked.) Integrated Equipment Short Circuit Rating The term “Integrated Equipment Short Circuit Rating” refers to the application of series connected circuit breakers in combination that allows some breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by UL. Standards NEC: 2005 NEMA: PB1 UL: 67 and 50. Listed by Underwriter’s Laboratories, Inc., under “Panelboards” File #E2269, and #E4016. Meets Federal Specification W-P-115c. 10-6 General Wire Connectors Standard wire connectors in Siemens panels are suitable for copper or aluminum cables rated 60/75 degree. Copper main lugs are price added option for most panel types and some Circuit Breakers (check with Siemens sales for availability). It should be noted that most copper lugs will only accept copper cables. Some applications, 100% rated devices in particular, require that the cable and connectors be rated 90 degree but are sized to the 75 degree tables. Grounds Standard ground connectors are also suitable for copper or aluminum wire. Ground connector assemblies (EGK, IGK) have (7) 1/0 max. and (15) #6 max. connections. The 1/0 holes are capable of connecting up (3) #10 max. wires. Copper ground assemblies (ECGK, ICGK) are rated for copper wire only and have the same wiring capacity as the Al/Cu connectors. Neutral Connectors Standard neutrals, like standard main lugs, are also rated for copper or aluminum wire. The neutral cross bar material follows the selection bus. Copper neutral lugs are rated for copper cable only and available as a price added option. Panel Mounting Wall Shown mounted in wall Wall Shown mounted on surface of wall Space Required for Mounting of Double Panels Use two or more panelboards with feed-thru or subfeed lugs when: 1. Lighting and appliance panelboards are required with more than 42 circuits. 2. More circuit mounting space is required than is provided in the largest box size. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Feed-Thru Lugs Subfeed Lugs or Double Lugs Feed-thru lugs are mounted at the opposite end of the main bus from the main lugs or main breaker and are used to connect two or more panelboards to the incoming feeder. The feeder cables are brought into Panelboard 1 and connected to the main lugs or main breaker. Cables interconnecting the two panelboards are connected to the feed-thru lugs in Panelboard1 and are carried over the main lugs in Panelboard 2. This arrangement could be reversed with the main lugs located at the top and the feed-thru lugs at the bottom of the panel. Subfeed lugs are mounted directly beside the main incoming lugs and are used to connect two or more panelboards to the incoming feeder. The feeder cables are brought into Panelboard 1 and connected to the main lugs. Another set of cables that are the same size are connected to the subfeed lugs of Panelboard 1 and are carried over the main lugs of Panelboard 2. Panelboards General Specifications General As standard, branch breakers shall be mounted at the top of the panel with “spaces” at the bottom, regardless of the direction panel is fed. Bussing Sequence Interiors are designed to accommodate top or bottom feed. Regardless of which is specified, the uppermost pole is always on “A” phase; the second pole down is always on “B” phase, and the third pole down is always on ”C” phase (assuming 3Ø panel). Circuit Breaker Lighting Panel Type P1 Circuit Breaker Lighting or Distribution Panel Types P2/P3 All breakers have bolted connections except plug-in type. The panel design provides bracing up to 200,000A IR UL short circuit rating. Case-hardened, high performance, thread rolling screws are used on branch bus. Circuit Breaker Distribution Panel Type P4/P5 Fusible Switch Distribution Panel Type P4/P5 Panelboard Ratings P1 P2 P3 P4 P5 Max. Voltage 600V AC Max. 500V DC Max. 1-Phase, 2-Wire 1-Phase, 3-Wire 3-Phase, 3-Wire 3-Phase, 4-Wire 125A-600A 100A-600A — 600V AC Max. 500V DC Max. 1-Phase, 2-Wire 1-Phase, 3-Wire 3-Phase, 4-Wire 3-Phase, 3-Wire 250A-800A 225A-600A — 600V AC Max. 500V DC Max. 1-Phase, 3-Wire 3-Phase, 4-Wire 3-Phase, 3-Wire 600V AC Max. 500V DC Max. 1-Phase, 3-Wire 3-Phase, 4-Wire 3-Phase, 3-Wire Main Lugs Main Breaker Main Switch 480Y/277V AC Max. 250V DC Max. 1-Phase, 2-Wire 1-Phase, 3-Wire 3-Phase, 3-Wire 3-Phase, 4-Wire 125A-400A 100A-400A — 400A-1200A 400A-800A 100A-200A 800A-1200A 800A-1200A 400A-1200A Circuits 18, 30, 42 18, 30, 42, 54 — — — Branch Ratings 15-125A 15-225A 15-600A 15-600A C/B 30-200A Fusible 15-1200A C/B 30-1200 Fusible Branch Disconnect Devices BL, BLH, HBL, BQD, NGB, BQD6, BLE, BLEH, BLF, BLHF, BAF, BAFH, BGL BL, BLH, HBL, BQD, NGB, NEB, HEB, BQD6, QJ2, HQJ2, QJ2H, HQJ2H , ED4, HED4, ED6, HHED6, BLE, BLEH, BLF, BLHF, BAF, BAFH, BGL BL, BLH, HBL, BQD, NGB, NEB, HEB, BQD6, QJ2, HQJ2, QJ2H, HQJ2H , ED4, HED4, ED6, HHED6, BLE, BLEH, BLF, BLHF, BAF, BAFH, BGL All 15-600A Breakers and MG at 800 Amps, 30-200A Fusible Switches All 15-1200A C/B 30A-200A VB Switches 400-1200A HCP Switches Subfeed Circuit Breakers NGB, ED4, ED6, HED4, HED6, QJ2, QJH2, QJ2-H, FXD6, FD6, HFD6, HFXD6 JD6, JXD6, HJD6, HJXD6, FD6, HFD6, FXD6, HFXD6 JD6, JXD6, HJD6, FD6, HFD6, FXD6, HFXD6 — — Enclosure Heights Inches – (mm) 32, 38, 44 @250A (813, 965, 1118) 56, 62, 68 @400A (1422, 1575, 1727) 26, 32, 38, 44, 50, 56, 62, 68, 74 (660-1880) 56, 62, 68, 74, 80 (1422-2032) 60, 75, 90 (1524, 1905, 2286) 60, 75, 90 (1524, 1905, 2286) Standard Trims Fas-Latch – 1 Piece Surface or Flush Fas-Latch – 1 Piece Surface or Flush Fas-Latch – 1 Piece Surface or Flush Four Piece Surface Four Piece Surface System Functional pricing is based on circuits shown. However, the panel can be figured with less circuits. P1 can have (1) subfeed breaker. P2 and P3 can have up to (2) FD subfeed breakers. JD and FD breakers are mounted vertical. Limitations apply. Trim ring provided for flush applications. maximum of (4) QJ breaker may be mounted in a P2 Panel and are single mounted. A maximum of (6) QJ breakers may be mounted in a P3 panel and are twin mounted. A P1 panels with NGB breakers are limited to NGB branch devices only. BL and BQD frames may not be mixed in this panel type. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-7 PANELBOARDS 10 Description Panelboards General Specifications General Typical Panelboard Modifications Lighting and Distribution Panelboards P1 P2 Description Box Type 3R/12 Type 4, 4X Drip Proof Drip Proof Hood Only Sealed Box Gasketed Trim Wider Box Deeper Box • • • • • • • — • • • • • • • • Front Hinged Front Door-in-Door Front Common Front Split Door Special Locks Nameplate • • • • • • • • • • • • Interior Aluminum Equipment Ground Bar Copper Equipment Ground Bar Insulated Equipment Ground Subfeed Lugs Feed-Thru Lugs Split Bus Compression Lugs Copper Lugs 200% Neutral Aluminum 햲 햲 Standard Standard • • — • — • • • P3 Distribution Panelboards P4 P5 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • — — — — Standard • • • • • • • • • • • • • • • • Standard • • • • Standard Standard • • • • • • • • • • • • • • Standard Check Plant For Availability Standard Check Plant For Availability Standard Temperature Rated Temp. Rise Over Ambient - Copper 750 Ampere / in. - Aluminum 햲 1000 Ampere / in. - Copper Standard Copper Plating - Silver or Tin Tin Tin Std./ Silver Optional Tin Std./ Silver Optional Silver Std./ Tin Optional Silver Std./ Tin Optional Remote Control Switches Time Clocks Circuit Breaker Shunt Trips R, J and T Fuse Clips External Mounted External Mounted • • • • • • • — — — • • • • • • • • All aluminum bus is tin-plated. • • • • — — • • • • • • • • • • Available as an option. UL Fuse Classes 햲 Interrupting Ratings (kA) l 2 t, l i Circuits — Less than 10,000A Available l•t – RK5 up to 100A, li – RK5 up to 100A l•t – Low, li – Low l•t – Slightly > J, li – Slightly > J Feeder circuits Feeder circuits (motor load small %) Feeder circuits (motor load small %) To 200 l•t – > RK-1, li – > RK-1 l•t – Low, li – Low Non-Motor loads 200 l•t – Low, li – Low Mains, feeder circuits Class Amperes Volts H 1-600 250 and 600V or less AC 10 K5 햳 1-600 250 and 600V or less AC 100 J RK1 1-600 1/10-600 600V or less 600V or less and 250V or less 200 200 RK5 1/10-600 600V or less and 250V or less 200 T 1-800, 1-1200 300 and 600V or less AC L 601-1200 600V or less 햲 Per UL 67. Fuses do not prohibit the use of Class H type fuse in switch. PANELBOARDS 10 햳 10-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Motor starting currents a factor Panelboards Unassembled Reference Catalog Numbering System Type P1 unassembled panelboards are completely convertible from main lug to main breaker and vice-versa. Additionally feed-thru lugs, or a subfeed circuit breaker up to 400 amperes can be added without increasing the box height. Follow these easy steps to select and price the proper P1 panel from stock: 4. List required branch circuit breakers and filler plates to cover any unused positions. 5. Select any modifications or accessories. 6. Compute total list price. 1. Compute total number of poles to determine interior catalog number. 2. List catalog number and price of interior, box and front. 3. Select main lug kit or main breaker kit from appropriate tables. Note: Main/Subfeed Breaker mounting kits may be ordered with or without breakers included, see page 10-11 and 10-12 for selection. P 1 X 1 8 䊱 䊱 䊱 䊱 䊱 M C 䊱 䊱 2 5 0 A 䊱 䊱 䊱 䊱 1. P1 2. Voltage and System X = 208Y/120, 3-Phase 4-Wire A = 120/240V, 1-Phase 3-Wire E = 480Y/277V, 3-Phase 4-Wire 3, 4. Circuit – 18, 30, 42 5, 6. Mains MC = Convertible mains Select Main Lug Kit or Breaker Mounting Kit from page 10-11—10-12 Select Main Breaker Kit from page 10-11—10-12 7, 8, 9. Amperage – 400A max 10. Main Bus Material A = Aluminum C = Copper Note:Standard bussing in P1 panels is tin plated for aluminum and copper. Standard bus is temperature rated to the maximum amperage in the panel. Branch Breakers Panel Type P1 Voltage (Max.) Breaker Type 240 BI, BLH, HBL, BQD 480/277 BQD 600/347 BQD Speedfax Page See section 6 10 PANELBOARDS 햲 Consult sales office for availability of CSA. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-9 Panelboards Distributor Stock Selection Pricing An Unassembled Panel 400A Max. — 20" Wide x 5.75" Deep 1. Choose the appropriate Interior from the table below. 2. Choose and price the Main Device: Main Lugs from pages 10-11, Main Breaker Kit from page 10-13 and Main Breakers from Section 6. 3. Choose and price Branch Breakers. BL, BQD and NGB breakers from Section 6. 4. Choose and price Feed-Thru Lugs or Subfeed Breaker Feed-Thru Lugs from page 10-11, Subfeed Breaker Kit from page 10-11, and Subfeed Breaker from Section 6. Type P1 Unassembled Panelboards Convertible Mains — 1-Phase, 3-Wire 120 / 240V Interiors Only–Less Branch Breakers Total List Price $ Amperes Rating Mains 836.50 975.50 1201.50 Boxes Fronts Max. No of Poles Interiors List Price $ Height (inches) Type 1 250 18 30 42 P1A18MC250A P1A30MC250A P1A42MC250A 630.00 787.00 1042.00 32 38 44 B32 B38 B44 1303.00 1443.00 1669.00 400 18 30 42 P1A18MC400A P1A30MC400A P1A42MC400A 979.00 1138.00 1393.00 56 62 68 893.50 1066.50 1310.50 250 18 30 42 P1A18MC250C P1A30MC250C P1A42MC250C 694.00 889.00 1165.00 1389.00 1562.00 1806.00 400 18 30 42 P1A18MC400C P1A30MC400C P1A42MC400C List Price $ Type 3R/12햲 List Price $ Surface Flush List Price $ 52.00 52.00 52.00 WP32 WP38 WP44 1690.00 1690.00 1690.00 S32B S38B S44B F32B F38B F44B 262.00 262.00 262.00 B56 B62 B68 107.00 107.00 107.00 WP56 WP62 WP68 1841.00 1841.00 1841.00 S56B S62B S68B F56B F62B F68B 384.00 384.00 384.00 32 38 44 B32 B38 B44 52.00 52.00 52.00 WP32 WP38 WP44 1690.00 1690.00 1690.00 S32B S38B S44B F32B F38B F44B 262.00 262.00 262.00 1077.00 1272.00 1548.00 56 62 68 B56 B62 B68 107.00 107.00 107.00 WP56 WP62 WP68 1841.00 1841.00 1841.00 S56B S62B S68B F56B F62B F68B 384.00 384.00 384.00 Convertible Mains — 3-Phase, 4-Wire 836.50 1068.50 1301.50 208Y /120V 250 18 30 42 P1X18MC250A P1X30MC250A P1X42MC250A 630.00 891.00 1154.00 32 38 44 B32 B38 B44 52.00 52.00 52.00 WP32 WP38 WP44 1690.00 1690.00 1690.00 S32B S38B S44B F32B F38B F44B 262.00 262.00 262.00 1373.00 1604.00 1838.00 400 18 30 42 P1X18MC400A P1X30MC400A P1X42MC400A 1059.00 1320.00 1584.00 56 62 68 B56 B62 B68 107.00 107.00 107.00 WP56 WP62 WP68 1841.00 1841.00 1841.00 S56B S62B S68B F56B F62B F68B 384.00 384.00 384.00 896.50 1152.50 1402.50 250 18 30 42 P1X18MC250C P1X30MC250C P1X42MC250C 697.00 987.00 1269.00 32 38 44 B32 B38 B44 52.00 52.00 52.00 WP32 WP38 WP44 1690.00 1690.00 1690.00 S32B S38B S44B F32B F38B F44B 262.00 262.00 262.00 1489.00 1743.00 1994.00 400 18 30 42 P1X18MC400C P1X30MC400C P1X42MC400C 1190.00 1477.00 1760.00 56 62 68 B56 B62 B68 107.00 107.00 107.00 WP56 WP62 WP68 1841.00 1841.00 1841.00 S56B S62B S68B F56B F62B F68B 384.00 384.00 384.00 250 P1E18MC250A P1E30MC250A P1E42MC250A 630.00 891.00 1154.00 32 38 44 B32 B38 B44 52.00 52.00 52.00 WP32 WP38 WP44 1690.00 1690.00 1690.00 S32B S38B S44B F32B F38B F44B 262.00 262.00 262.00 10 1373.00 1743.00 1838.00 400 18 30 42 P1E18MC400A P1E30MC400A P1E42MC400A 1059.00 1320.00 1584.00 46 62 68 B56 B62 B68 107.00 107.00 107.00 WP56 WP62 WP68 1841.00 1841.00 1841.00 S56B S62B S68B F56B F62B F68B 384.00 384.00 384.00 896.50 1152.50 1402.50 250 18 30 42 P1E18MC250C P1E30MC250C P1E42MC250C 697.00 987.00 1269.00 32 38 44 B32 B38 B44 52.00 52.00 52.00 WP32 WP38 WP44 1690.00 1690.00 1690.00 S32B S38B S44B F32B F38B F44B 262.00 262.00 262.00 1489.00 1743.00 1994.00 400 18 30 42 P1E18MC400C P1E30MC400C P1E42MC400C 1190.00 1477.00 1760.00 56 62 68 B56 B62 B68 107.00 107.00 107.00 WP56 WP62 WP68 1841.00 1841.00 1841.00 S56B S62B S68B F56B F62B F68B 384.00 384.00 384.00 햲 836.50 1068.50 1301.50 480Y / 277V 18 30 42 PANELBOARDS Convertible Mains — 3-Phase, 4-Wire Front included in NEMA 3R Box. 10-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule UNPB Panelboards Distributor Stock Selection Type P1 Panelboards Type P1 Panelboards Lug Kits — Main or Feed Thru Breaker Mounting Kits 250A Max. — Main or Subfeed w/o Breaker Ampere Rating Material Wire Range Service Catalog Number List Price $ (1) #6 AWG–350 kcmil 1-Phase MLKA1 Cu or Al 208.00 (1) #6 AWG–350 kcmil 3-Phase MLKA3 Cu or Al 262.00 (1) #6 AWG–350 kcmil 1-Phase MLKC1 Cu or Al 388.00 (1) #6 AWG–350 kcmil 3-Phase MLKC3 Cu or Al 500.00 Al (2) 3/0 250 or (1) 600 kcmil 1-Phase 4MLKA1 3-Phase 4MLKA3 791.00 879.00 Cu (2) 3/0 250 or (1) 600 kcmil 1-Phase 4MLKC1 1059.00 3-Phase 4MLKC3 1307.00 AI 250 Cu 400 Copper Neutral Lug Kits — 250A Number of Circuits Description Catalog List Number Price $ 18 2 Branch Neutral Strips, 1 Main Neutral Lug, CNLK18 Hardware 208.00 30 2 Branch Neutral Strips, 1 Main Neutral Lug, CNLK30 Hardware 229.00 42 2 Branch Neutral Strips, 1 Main Neutral Lug, CNLK42 Hardware 251.00 햲 Ampere Rating Breaker Types Service Catalog Number List Price $ 100A BQD 3-Phase MBKBC3 586.00 100A BL, BLH, HBL 1-Phase 3-Phase MBKBL1 MBKBL3 208.00 586.00 125A NGB 1-Phase 3-Phase MBKNB1 MBKNB3 498.00 1063.00 125A ED4, ED6, HED4, HED6 1-Phase 3-Phase MBKED1 MBKED3 498.00 1063.00 225A QJ2, QJH2, QJ2-H 1-Phase 3-Phase MBKQJ1 MBKQJ3 498.00 1063.00 250A FXD6, FD6, HFD6 1-Phase 3-Phase MBKFD1 MBKFD3 797.00 939.00 400A햲 JXD2, JD6, JXD6, HJD6, HJXD6 1-Phase 3-Phase MBKJD1 MBKJD3 2381.00 2755.00 400 amp kit is for main—only not allowed for subfeed breaker. 200% Neutral Lug Kits/250A 18 2 Branch Neutral Strips, 2 Main Neutral Lug, 2NLK18 Hardware 310.00 30 2 Branch Neutral Strips, 2 Main Neutral Lug, 2NLK30 Hardware 330.00 42 2 Branch Neutral Strips, 2 Main Neutral Lug, 2NLK42 Hardware 351.00 MBKQJ3 200% Neutral Lug Kits/400A and 600A 18 30 42 42NLK18 2 Branch Neutral Strips, 4 Main Neutral Lug, 42NLK30 Hardware 42NLK42 487.00 487.00 487.00 Type P1, P2, and P3 Panelboards Miscellaneous Parts and Accessories Catalog Number EGK BK1 EWK2 Discount Schedule UNPB 20.00 20.00 13.00 7.00 3.00 3.00 9.00 9.00 8.00 8.00 21.00 57.00 67.00 MBKFD3 33.00 33.00 2.80 3.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog PANELBOARDS QF3 EBF1 List Price $ 18.00 20.00 10 BK2 BK3 IMK1 11-1824-01 12-1110-01 11-1056-01 NBK03 NBK04 NBK05 NBK06 ECGK IGK ICGK EWK1 Description Al Ground Bus 44 Connections Bonding kit for 250A max. and all P1 panels Bonding kit for S1/S2 400 & 600 Bonding kit Interior Adjusting Kit Directory Card Holder Directory Card NEMA Instruction Book Number Strips 1–42 Number Strips 43–84 Number Strips 85–126 Number Strips 127–168 Cu Ground Bus 44 Connections Insulated Al Ground Bus Insulated Cu Ground Bus End Wall Kit with Knockouts (20" W x 5.75" DP) End Wall Kit with Knockouts (24" W x 7.75" DP) Filler Plate NEB/HEB Filler Plate 10-11 Panelboards Panelboard Replacement, Modification, and Additions Selection S1/S2 Panels—All the P1 panel kits for 250 amp and below panels will work for 250 amp maximum S1/S2 panels. 400/600 Amp S1/S2 and All SE Panels Lug Kits — Main or Feed Thru Ampere Rating Material Wire Range Service 125A / 250A Al/Cu (2) 1/0–250 kcmil 1-Phase MLKA1 208.00 125A / 250A Al/Cu (2) 1/0–250 kcmil 3-Phase MLKA3 262.00 Al/Cu (2) #4–250 kcmil or (1) 3/0–500 kcmil 1-Phase SMLKA1 791.00 Al/Cu (2) #4–250 kcmil or (1) 3/0–500 kcmil 3-Phase SMLKA3 879.00 400A / 600A 400A / 600A Catalog Number List Price $ Breaker Mounting Kits Ampere Rating Breaker Types Catalog Service Number List Price $ 125A ED2, ED4, ED6, HED4, HED6, HHED6 1-Phase SMBKED1 225A ED2, ED4, ED6, HED4, HED6, HHED6 3-Phase SMBKED3 1273.00 670.00 225A QJ2, HQJ2, HQJ2H 햲 225A QJ2, HQJ2, HQJ2H 햲 3-Phase SMBKQJ3 2007.00 250A FXD6, FD6, HFXD6, HFD6 1-Phase SMBKFD1 250A FXD6, FD6, HFXD6, HFD6 3-Phase SMBKFD3 1128.00 400A JD6, JXD6, HJD6, HJXD6 1-Phase SMBKJD1 2381.00 400A JD6, JXD6, HJD6, HJXD6 3-Phase SMBKJD3 2755.00 600A LD6, LXD6, HLD6, HLXD6 1-Phase SMBKLD1 2533.00 600A LD6, LXD6, HLD6, HLXD6 3-Phase SMBKLD3 2854.00 1-Phase SMBKQJ1 1786.00 955.00 Neutral Kits Ampere Rating Description Catalog Number List Price $ 250A max. 30/42 circuit 200% neutral kit 2NLK2 464.00 400/600A max. 42 circuit 200% neutral kit 2NLK1 487.00 PANELBOARDS 10 Other applications: For P4/S4 and 10" deep SPP panels see page 10-50 for branch breaker mounting kits. For P5/S5 and 12.75" deep SPP panels see page 10-61 for branch breaker mounting kits. For P4/F1 and 10" deep FPP panels see page 10-50 for branch fusible switch mounting kits. For P5/F2 and 12.75" deep FPP panels see page 10-61 for branch fusible switch mounting kits. For Series 5, Series 6, CDP6 and VB 6 panels as well as FC20, FCI, FCII, SB1, SB2 and SB3 distribution switchboards, see page 12-32 for branch device mounting kits. 햲 QJ mounting kit is for subfeed breakers only, not main breaker. The kit contains mountings for (2) breakers. 10-12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule UNPB Sentron® Panelboards Warehouse Stock/Unassembled Selection Main Breaker Mounting Kits w/Breakers for P1 panels Catalog Number Description Ratings 240V 480V MBKED3100 Kit w/3-pole ED4 100A breaker 65KA 18KA 1869.00 MBKED3125 Kit w/3-pole ED4 125A breaker 65KA 18KA 3197.00 MBKQJ1125 Kit w/2-pole QJ2 125A breaker 10KA — 1929.00 MBKQJ1150 Kit w/2-pole QJ2 150A breaker 10KA — 1929.00 MBKQJ1175 Kit w/2-pole QJ2 175A breaker 10KA — 1929.00 MBKQJ1200 Kit w/2-pole QJ2 200A breaker 10KA — 1929.00 MBKQJ1225 Kit w/2-pole QJ2 225A breaker 10KA — 1929.00 MBKQJ3125 Kit w/3-pole QJ2 125A breaker 10KA — 2757.00 MBKQJ3150 Kit w/3-pole QJ2 150A breaker 10KA — 2757.00 MBKQJ3175 Kit w/3-pole QJ2 175A breaker 10KA — 2757.00 MBKQJ3200 Kit w/3-pole QJ2 200A breaker 10KA — 2757.00 MBKQJ3225 Kit w/3-pole QJ2 225A breaker 10KA — 2757.00 MBKQJ1125H Kit w/2-pole QJ2H 125A breaker 42KA — 2115.00 MBKQJ1150H Kit w/2-pole QJ2H 150A breaker 42KA — 2115.00 MBKQJ1175H Kit w/2-pole QJ2H 175A breaker 42KA — 2115.00 MBKQJ1200H Kit w/2-pole QJ2H 200A breaker 42KA — 2115.00 MBKQJ1225H Kit w/2-pole QJ2H 225A breaker 42KA — 2115.00 MBKQJ3125H Kit w/3-pole QJ2H 125A breaker 42KA — 3144.00 MBKQJ3150H Kit w/3-pole QJ2H 150A breaker 42KA — 3144.00 MBKQJ3175H Kit w/3-pole QJ2H 175A breaker 42KA — 3144.00 MBKQJ3200H Kit w/3-pole QJ2H 200A breaker 42KA — 3144.00 MBKQJ3225H Kit w/3-pole QJ2H 225A breaker 42KA — 3144.00 MBKFD3150 Kit w/3-pole FXD6 150A breaker 65KA 35KA 3301.00 MBKFD3175 Kit w/3-pole FXD6 175A breaker 65KA 35KA 3301.00 MBKFD3200 Kit w/3-pole FXD6 200A breaker 65KA 35KA 3301.00 MBKFD3225 Kit w/3-pole FXD6 225A breaker 65KA 35KA 3301.00 MBKFD3250 MBKJD1300 Kit w/3-pole FXD6 250A breaker Kit w/2-pole JXD6 300A breaker 65KA 65KA 35KA — 4612.00 4534.00 List Price $ MBKJD3300 Kit w/3-pole JXD6 300A breaker 65KA 35KA 5974.00 MBKJD1400햲 Kit w/2-pole JXD6 400A breaker 65KA 35KA 4534.00 MBKJD3400햲 Kit w/3-pole JXD6 400A breaker 65KA 35KA 5974.00 Branch Breakers Selection for P1 Selection Guide 1. Select breaker type. 2. Select required amperage. 3. Select number of poles. 4. Select branch breaker catalog numbers. 5. Select ground bar and filler plates. (See replacement parts & accessories on Page 10-11.) AFCI Arc Fault Circuit Interrupter Interrupting Ratings (kA) RMS Symmetrical Amperes Volts AC Breaker Type Ampere Rating Catalog Number 120 120/240 240 BAF 1-Pole 15 20 B115AF B120AF 10 10 — — — — BAFH 1-Pole 15 20 B115AFH B120AFH 22 22 — — — — Switching Neutrals 햲 Interrupting Ratings (kA) RMS Symmetrical Amperes Volts AC Breaker Type Ampere Rating Catalog Number 120 120/240 240 BG 2-Wire Common Trip 15 20 30 BG215 ■ BG220 ■ BG230 ■ 10 10 10 — — — — — — BG 3-Wire Common Trip 15 20 30 BG315 ■ BG320 ■ BG330 ■ — — — 10 10 10 — — — 10 PANELBOARDS 햲 400 Amp Kit used as Main only. And for top feed applications only. Discount Schedule UNPB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-13 Sentron® Panelboards Warehouse Stock/Unassembled Selection Branch Breakers Selection for P1 Selection Guide 1. Select breaker type. 2. Select required amperage. 3. Select number of poles. 4. Select branch breaker catalog numbers. 5. Select ground bar and filler plates. (See replacement parts & accessories on Page 10-11.) BL Branch Breakers – 10,000A IR BLH Branch Breakers – 22,000A IR Amp Rating 1-Pole 120/240V 2-Pole 120/240V 2-Pole 240V 3-Pole 240V Amp Rating 1-Pole 120/240V 2-Pole 120/240V 3-Pole 240V 15 20 25 30 35 40 45 50 55 60 70 80 90 100 110 125 B115 B120 B125 B130 B135 B140 B145 B150 B155 B160 B170 — — — — — B215 B220 B225 B230 B235 B240 B245 B250 — B260 B270 B280 B290 B2100 B2110 B2125 B215R B220R B225R B230R B235R B240R B245R B250R — B260R B270R B280R B290R B2100R — — B315 B320 B325 B330 B335 B340 B345 B350 — B360 B370 B380 B390 B3100 — — 15 20 25 30 40 50 55 60 70 80 90 100 B115H B120H B125H B130H B140H B150H B155H B160H B170H — — — B215H B220H B225H B230H B240H B250H — B260H B270H B280H B290H B2100H B315H B320H B325H B330H B340H B350H — B360H B370H B380H B390H B3100H HBL Branch Breakers – 65,000A IR Amp Rating 15 20 30 40 50 60 70 80 90 100 1-Pole 120/240V 2-Pole 120/240V 3-Pole 240V B115HH B120HH B130HH B140HH B150HH — — — — — B215HH B220HH B230HH B240HH B250HH B260HH B270HH B280HH B290HH B2100HH B315HH B320HH B330HH B340HH B350HH B360HH B370HH B380HH B390HH B3100HH BQD Branch Breakers – 14,000A IR Max. @ 480/277 Vac / 65,000A IR max. @ 240 Vac Amp Rating 1-Pole 277V 2-Pole 480Y/277V 3-Pole 480Y/277V 15 20 25 30 35 40 45 50 60 70 80 90 100 BQD115 BQD120 BQD125 BQD130 BQD135 BQD140 BQD145 BQD150 BQD160 BQD170 BQD180 BQD190 BQD1100 BQD215 BQD220 BQD225 BQD230 BQD235 BQD240 BQD245 BQD250 BQD260 BQD270 BQD280 BQD290 BQD2100 BQD315 BQD320 BQD325 BQD330 BQD335 BQD340 BQD345 BQD350 BQD360 BQD370 BQD380 BQD390 BQD3100 GFCI Personnel Protection (5MA) PANELBOARDS 10 Interrupting Ratings (kA) RMS Symmetrical Amperes Volts AC Breaker Type Ampere Rating Catalog Number 120 120/240 240 BLF 1-Pole 15 20 25 30 BF115 BF120 BF125 ■ BF130 10 10 10 10 — — — — — — — — BLF 2-Pole 15 20 30 40 50 60 BF215 BF220 BF230 BF240 ■ BF250 ■ BF260 ■ — — — — — — 10 10 10 10 10 10 — — — — — — BLHF 1-Pole 15 20 30 BF115H BF120H BF130H ■ 22 22 22 — — — — — — BLHF 2-Pole 15 20 30 40 50 60 BF215H ■ BF220H ■ BF230H ■ BF240H ■ BF250H ■ BF260H ■ — — — — — — 22 22 22 22 22 22 — — — — — — ■ Built to order. Allow 2–3 weeks for delivery. 햲 HACR rated. 10-14 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Panelboards Factory Assembled Selection P 1 C 4 2 F X 2 5 0 A T S Catalog Numbering System Type of Panel P1, P2, P3, P4, P5 Voltage and System C = 208Y/120 3Ø 4 W Wye AC - All E = 480Y/277 3Ø 4 W Wye AC - All D = 240 3Ø 3 W Delta AC - All F = 480 3Ø 3 W Delta AC - All G = 600 3Ø 3 W Delta AC - P2, P3, P4, P5 I = 347 3Ø 3 W Delta AC P2, P3, P4, P5 B = 240/120 3Ø 4 W Delta BØ High Leg AC - All Q = 240/120 3Ø 4 W Delta CØ High Leg AC - All X = 120/240 2Ø 5 W Single Neutral AC - P2, P3, P4, P5 A = 120/240 1Ø 3 W Grounded Neutral AC (2) - All H = 120 1Ø 2 W Grounded Neutral AC (2) - All J = 240 1Ø 2 W No Neutral AC (3) - All Y = 125 1Ø 2 W Grounded Neutral AC (2) - P2, P3, P4, P5 Z = 500 2W DC - P2, P3, P4, P5 K = 220/127 3Ø 4 W Wye AC - All M = 380/220 3Ø 4 W Wye AC - All R = 415/240 3Ø 4 W Wye AC - All S = 440/250 3Ø 4 W Wye AC - All L = 600/347 3Ø 4 W Wye AC - All T = 230 3Ø 3 W Delta AC - All Z = 380 3Ø 3 W Delta AC - P2, P3, P4, P5 1 = 24V DC 1-Pole Branches Only (3) - All 2 = 24V DC 2-Pole Branches Only (3) - All 3 = 48V DC 1-Pole Branches Only (3) - All 4 = 48V DC 2-Pole Branches Only (3) - All 5 = 125V DC 1-Pole Branches Only (3) - All N = 125V DC 2-Pole Branches Only - All O = 125/250V DC 2-Pole Branches Only - All P = 125/250V DC 2 & 3-Pole Branches - All U = 120V AC 3Ø3W - All V = 240V 3Ø3W Grounded B Phase - All Circuits or Enclosure Height P1 – 18, 30, 42 P3 – 56, 62, 68, 74, 80 P2 – 18, 30, 42, 54 P4, P5 – 60, 75, 90 Main Lug (ML), Main Breaker (See Main Breaker Table coding below), Main Switch (MS) Amperage 100–400A = P1 250 – 800A = P3 100–600A = P2 400 –1200A = P4, P5 Bus Material Temp rated Al. 750A/sq. in. Al. Temp rated Cu. Temp rated Cu. Temp rated Cu. 1000A/sq. in. Cu. 1000A/sq. in. Cu. Bus Plating Tin-Plated Tin-Plated Tin-Plated Silver-Plated Tin-Plated Tin-Plated Silver-Plated Letter A B C E F G H Bus Code P1 P2 P3 P4 P5 A B C F E G H • n/a • n/a n/a n/a n/a • • • • optional • optional • • • • optional • optional • • n/a • • optional • • • n/a • • optional • • Indicates default for this bus type. Feed Location T = Top B = Bottom Mounting S = Surface F = Flush. Flush trims extend 1 1/2" beyond the base box dimensions on P1, P2 and P3 and 2" on P4 and P5 panels. Main Breaker Coding Panel must not be a lighting and appliance panel. See NEC article 384. Standard bussing in P1, P2 and P3 panels is tinplated for aluminum and copper. Standard bus is temperature rated to the maximum amperage in the panel. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-15 PANELBOARDS 10 (Breaker Type) Code (BAF) BA, (BAFH) BF, (BQD) BQ, (NGB) NB, (BQD6) B6, (BL) BL, (BLEH) BE, (BLH) BH, (BLR) BR, (HBL) HB, (BGL-SWI) B1, (BLE-GFCI) BG, (BLF-GFCI) BC, (CED6) CE, (ED4) E4, (ED6) E6, (HED4) H4, (HHED6) HA, (BLHF-GFCI) B4, (BL-HID) B2, (HQP) HQ, (QP) QP, (QPH) PQ, (QJ2) QJ, (QJ2H) Q2, (QJH2) QH, (CFD6) CF, (FD6) FD, (FXD6) FX, (HFD6) HF, (HFXD6) H2, (HHFD6) H1, (HHFXD6) H3, (CJD6) CJ, (HHJD6) 6H, (HHJXD6) H9, (HJD6) H6, (HJXD6) H5, (HJXD6H) H7, (HQJ2H) Q3, (JD6) J6, (JXD2) JD, (JXD2H) J2, (JXD6) JX, (JXD6H) JH, (CLD6) CL (HHLD6) HH, (HHLXD6) XH, (HLD6) HL, (HLXD6) HO, (HLXD6H) HP, (LD6) L6, (LXD6) LX, (LXD6H) HL, (HLMD6) HJ, (HLMXD6) HK, (LMD6) L1, (LMXD6) LM, (NMX) M1, (HMX) M2, (LMX) M3, (NNX) N1, (HNX) N2, (LNX) N3, (NNY) N4, (HNY) N5, (LNY) N6, (CMD6H) CH, (HMD6) HM, (HMXD6) HR, (HMXD6H) HS, (MD6) MD, (MXD6) MX, (MXD6H) MH, (CND6) CN, (CND6H) C6, (HND6) HN, (HNXD6) HT, (HNXD6H) HX, (ND6) ND, (NXD6) NX, (NXD6H) NT Panelboards Circuit Breaker / Lighting and Distribution Pricing Types P1 Example No. 2 is a two section panel, each having 42 circuits. Section One will contain 1-225/3 QJ2 main breaker (top feed), 250A feed-thru lugs and 21" of unit space. Section Two will contain 250A main lugs only (bottom feed) and 21" of unit space. Sections will be 44" in height. 1) To specify a particular panelboard; list panel catalog number, branches, modifications, and price on an Estimate Sheet. Price includes interior with provisions, box, ground bar, and trim. See Example No. 1. 2) When more than 42 circuits are specified for P1 a two section panel will be required. Feed-thru lugs must be priced in one section from the modifications on pages 10-20. Panel LPA Panel LPB 1 — P1C30QJ225ATS 10–20/1 25. ea. 4–30/3 140. ea. 2540. 250. 560. 1 — P1C42QJ225ATS 1 — P1C42ML250ATS 1 — Feed-Thru Lugs 3350. 3) Standard main breakers are indicated by the 6th and 7th positions in the catalog number. If any other main breaker type is required, replace with the appropriate code from page 10-18. See Example No. 3. 4) All panel modifications must be listed and priced separately. 5) If the boxes are to be sized the same then each panel must have the same amount of unit space. Panel LPC 2760. 1330. 190. 4280. 1 — P1C42HF250CTS HFD6 Main 42–20/1 BLH 35. ea. Cu Bus Type 3R 3160. 1900. 1470. 255. 860. 7645. Example No. 1 Example No. 2 Example No. 3 Type P2 Boxes will be sized the same for two section panels. Base price includes all provisions. Subfeed or feed-thru lugs as required must be priced from page 10-28. Example No. 4 is a two section panel, each having 42 circuits. Section One will contain 1-400/3 JXD6 main breaker (top feed), 225A feed-thru lugs, and 21" of unit space. Section Two will contain 400A main Type P2 panelboards are priced the same as Type P1 described above except for two section panels. 1) When more than 42 circuits are specified for P2, a two section panel will be assumed. Main breaker codes in the 5th and 6th positions will dictate the use of feed-thru lugs. An “ML” in the fifth and sixth positions will dictate the use of subfeed lugs for 125A and 250A and feed-thru lugs for 400A and 600A. PANELBOARDS 10 Types P3, P4 and P5 1) To specify a particular panelboard, first determine voltage, system, amperage and type of main, amperage and type of branch devices, and modifications if any. (Step 1) 2) List branch devices and modifications requiring space additions. List unit space requirements of each. Note: Some units are twin mounted meaning two breakers occupy the same unit space. Step #1 Step #2 Amperage Voltage System Main Branches Modification Feed Mounting 400 208Y/120 3-phase 4-wire Main Breaker 5-125/3, 2-225/3, 1-250/3 None Top Surface Unit Space Calculation 5-125/3 QJ2 5-225/3 QJ2 1-250/3 FXD6 5" = 15" 5" = 5" 5" = 5" 25" Enclosure is B275 from Selection Chart on page 10-41. (32" wide, 75" high, 10" deep). For inches / millimeters conversion, see Application Data section. 10-16 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog lugs only (bottom feed) and 21" of unit space. Sections will be 53" in height. Select appropriate enclosure height from selection chart on pages 10-34, 10-44, or 10-56, based on unit space requirements. (Step 2) 3) Select panelboard catalog number from appropriate table based upon voltage, system, amperage and unit space requirements. (Step 3) Step #3 1—P4C75JX400ATS 5-125/3 QJ2 940. 2-225/3 QJ2 940. 1-250/3 FXD6 2700. $04210. 4700. 1880. 2700. 13490. Panelboards Circuit Breaker / Lighting and Distribution Type P1 480Y/277 Vac Maximum 600Y/ 347 Vac (CSA only) Maximum 400 Ampere Mains 400 Ampere Maximum Branch UL Short Circuit Rating — 200,000 A. @ 240 Vac / 100,000 A. @ 480/277 Vac. IR Maximum Branch Breaker Symmetrical Interrupting Capacity Based on Underwriters’ Test Procedure Feed thru and subfeed lugs may result in lower interrupting ratings if not protected by a main device. Consult sales office. Meets 2005 NEC wire bending requirement, section 312.6. Meet Federal Specification W-P-115C. Panelboards Listed by Underwriters’ Laboratories, Inc., under ”Panelboards” File #E2269 for interiors and #E4016 for boxes and fronts. Service 1-phase 2-wire - 120 Vac, 240 Vac, 24 Vdc, 48 Vdc, 125 Vdc 1-phase 3-wire - 120/240 Vac, 125/250 Vdc 3-phase 3-wire - 480Y/277 (when derived from 3-phase 4-wire system), 240 Vac, 120 Vac, 125/250 Vdc 3-phase 4-wire - 208Y/120 Vac, 240/120 Vac, 480Y/277 Vac, 600Y/347 Vac, 380/220 Vac. Panelboard Fronts and Doors Standard panelboards are furnished with trim featuring concealed fasteners and hinges with a flush door lock. All are factory-assembled for ease of installation. Fronts are fabricated from code gauge steel and finished ANSI-61. See page 10-71 for optional fronts. Main Breakers BL, BLH, HBL, BQD, ED4, ED6, HED4, HHED6, QJ2, QJH2, QJ2-H, FXD6, FD6, HFD6, HFXD6, JXD6, JD6, HJXD6, HJD6. (All main breakers except 400 amp frame are mounted horizontal.) General Side Gutter Wiring Space (inches) Main Breaker Panel Connectors Ampere Rating Connectors Suitable for Cu or Al 100 (1)—#14 1/0 AWG 125 (1)—#4 1/0 AWG 225 (1)—#4 AWG–300 kcmil 250 (1)—#4/0 AWG–350 kcmil Al (1)—#6/0 AWG–350 kcmil Cu 400 (2)—#3/0 AWG–250 kcmil Al or (1)—#3/0 AWG–500 kcmil Al Connector ranges indicated do not apply to all main breaker types. Refer to molded case circuit breaker standard pressure wire connector chart (Section 6) for the connector range of a specific frame. Reference Letter A 6.375 7.375 B 5.500 7.500 C 6.125 8.125 D 6.500 8.500 E 5.250 7.250 F 5.000 7.000 Branch Breaker Side Gutters A B C D E F Main Lug Connectors 125 (1)—#6 AWG–350 kcmil 250 (1)—#6 AWG–350 kcmil 400 (2)—#3/0 AWG–250 kcmil or (1)—#3/0 AWG–600 kcmil Boxes 20" wide, 5.75" deep ▪ End walls are blank as standard. End walls with knockouts will be supplied at no charge on 5.75" deep panels if requested at time of order. Main Breaker Gutter Dimensions (inches) Side Gutter Main Breaker Neutral Location 20" 24" w/box w/box 20" w/box BL, BLH, HBL, BQD 8.500 10.500 11.500 NGB 8.000 10.000 11.500 ED4, ED6, HED4 6.125 8.125 11.500 QJ2, QJH2, QJ2-H 6.500 8.500 11.500 FD6, FXD6, HFD6 5.250 7.250 11.500 15.000 15.000 26.750 JD6, JXD6 Main Lug End Gutter Dimensions (inches) Amp Rating End Gutter Neutral Location 125 10.500 11.500 250 10.500 11.500 400 25.500 26.750 Panel Width 24" (Optional) Panel Width 20" BL, BLH, HBL BL, BLH, HBL BLF, BLHF BLF, BLHF BQD BQD ED, ED4, ED6, HED4, HHED6 QJ2, QJH2, QJ2-H FXD6, FD6, HFD6 NGB NGB A B F Weight — Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is: ▪ About 3 lbs. per inch of box height Gauge Steel Boxes Width Height Gauge Steel 20" All #16 Fronts — Surface, Flush 20" All #14 10 Series Connected Short Circuit Ratings The term “Series Connected Short Circuit Rating” refers to the application of series connected circuit breakers in a combination that allows some breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by UL. The table below lists specific main and branch breaker series combinations that are marked on all P1 panels. All combinations shown have been tested for use in P1 panelboards and are UL listed. Other combinations are available. See Circuit Breaker Section, of this book. These series ratings must be specified on order at time of entry. PANELBOARDS Feed-thru lug and neutral wire bending space is 15.000" P1 400 amp main breaker panels have wire bending space available for 600 kcmil. and 16.250" respectively on 400A panel. 400A main breaker is vertical mounted. P1 panel limited to (1) subfeed 250 amperes max. For inches / millimeters conversion, see Application Data section. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-17 Panelboards Circuit Breaker / Lighting and Distribution Selection Type P1 Shown with Standard Mains, Top Fed and Surface Trim Catalog number is for aluminum main bus. For optional copper main bus change “A” in position 11 to “C”. See copper price adder on page 10-20. Main Lugs Only Panels are top feed, surface mounted. For bottom feed, change “T” in position 12 to “B”. For flush mounting, change “S” in position 13 to “F”. Replace fifth and sixth position in panelboard catalog number, with alternate main breaker code. Use price adders from main breaker selection table. Horizontally mounted. Maximum Panel Ampere Rating Maximum 1-Pole Circuits Box Height (inches) 208Y/120V 3-Phase, 4-Wire Catalog Number List Price $ 120/240V 1-Phase, 3-Wire Catalog Number List Price $ 480Y/277V 3-Phase, 4-Wire Catalog Number List Price $ 125 18 30 42 32 38 44 P1C18ML125ATS P1C30ML125ATS P1C42ML125ATS 840.00 1060.00 1250.00 P1A18ML125ATS P1A30ML125ATS P1A42ML125ATS 750.00 980.00 1180.00 P1E18ML125ATS P1E30ML125ATS P1E42ML125ATS 910.00 1190.00 1440.00 250 18 30 42 32 38 44 P1C18ML250ATS P1C30ML250ATS P1C42ML250ATS 910.00 1100.00 1330.00 P1A18ML250ATS P1A30ML250ATS P1A42ML250ATS 820.00 1010.00 1230.00 P1E18ML250ATS P1E30ML250ATS P1E42ML250ATS 1020.00 1270.00 1540.00 400 18 30 42 56 62 68 P1C18ML400ATS P1C30ML400ATS P1C42ML400ATS 1240.00 1440.00 1710.00 P1A18ML400ATS P1A30ML400ATS P1A42ML400ATS 1110.00 1340.00 1580.00 P1E18ML400ATS P1E30ML400ATS P1E42ML400ATS 1240.00 1440.00 1710.00 Main Circuit Breaker 100 18 30 42 32 38 44 P1C18BL100ATS P1C30BL100ATS P1C42BL100ATS 1170.00 1370.00 1640.00 P1A18BL100ATS P1A30BL100ATS P1A42BL100ATS 1060.00 1250.00 1450.00 P1E18BD100ATS P1E30BD100ATS P1E42BD100ATS 1520.00 1740.00 2230.00 125 18 30 42 32 38 44 P1C18NB125ATS P1C30NB125ATS P1C42NB125ATS 1710.00 1920.00 2190.00 P1A18NB125ATS P1A30NB125ATS P1A42NB125ATS 1600.00 1790.00 2010.00 P1E18NB125ATS P1E30NB125ATS P1E42NB125ATS 1710.00 1920.00 2190.00 225 18 30 42 32 38 44 P1C18QJ225ATS P1C30QJ225ATS P1C42QJ225ATS 2350.00 2540.00 2760.00 P1A18QJ225ATS P1A30QJ225ATS P1A42QJ225ATS 1950.00 2150.00 2360.00 P1E18FX225ATS P1E30FX225ATS P1E42FX225ATS 2510.00 2780.00 3030.00 250 18 30 42 32 38 44 P1C18FX250ATS P1C30FX250ATS P1C42FX250ATS 2760.00 2950.00 3160.00 P1A18FX250ATS P1A30FX250ATS P1A42FX250ATS 2360.00 2550.00 2770.00 P1E18FX250ATS P1E30FX250ATS P1E42FX250ATS 2760.00 2950.00 3160.00 400 18 30 42 56 62 68 P1C18JX400ATS P1C30JX400ATS P1C42JX400ATS 3160.00 3370.00 4540.00 P1A18JX400ATS P1A30JX400ATS P1A42JX400ATS 2650.00 2850.00 3160.00 P1E18JX400ATS P1E30JX400ATS P1E42JX400ATS 3990.00 4190.00 4540.00 Main Breaker Selection (Cost adder for other than std.) PANELBOARDS 10 Ampere Breaker Maximum Interrupting Rating Catalog Rating Type 240 Vac 480/277 Vac Number List Price $ Available Trip Values 100 BL BLH HBL BQD 125 NGB ED4 HED4 HHED6 100 65 100 100 25 18 42 65 NB E4 H4 HA STD 55. 540. 540. 15, 15, 15, 15, 20, 20, 20, 20, 25, 25, 25, 25, 30, 30, 30, 30, 35, 35, 35, 35, 10 22 42 100 — — — — 35 35 65 65 100 QJ QH Q2 HQ FD FX HF H2 H1 STD @ 240 Vac 75. 160. 1360. 140. 140. 1760. 1760. 2120. 60, 60, 60, 60, 70, 70, 70, 70, 80, 80, 80, 80, 90, 90, 90, 90, 100, 100, 100, 100, 225 QJ2 QJH2 QJ2-H HQJ2H FD6 FXD6 HFD6 HFXD6 HHFD6 FD FX HF H2 H1 STD STD 1900. 1900. 2120. J6 JX H6 H5 STD STD 2270. 2270. 250 FD6 FXD6 HFD6 HFXD6 HHFD6 400 JD6 JXD6 HJD6 HJXD6 10 22 65 65 — — — 14 BL BH HB BQ STD @ 240 Vac 65. 400. 400. @ 240 Vac / STD @ 480/277 Vac 15, 15, 15, 15, 20, 20, 20, 20, 30, 30, 30, 30, 35, 35, 35, 35, 40, 40, 40, 40, 45, 45, 45, 45, 50, 50, 50, 50, 60, 60, 60, 60, 70, 70, 70, 70, 80, 80, 80, 80, 90, 90, 90, 90, 100 100 100 100 40, 40, 40, 40, 50, 50, 50, 50, 60, 60, 60, 60, 70, 70, 70, 70, 80, 80, 80, 80, 90, 90, 90, 90, 100, 100, 100, 100, 65 100 200 65 100 35 65 200 100 65 100 35 65 For inches / millimeters conversion, see Application Data section. 10-18 110, 110, 110, 110, 125, 125, 125, 125, 150, 150, 150, 150, 175, 175, 175, 175, 200, 200, 200, 200, 110, 110, 110, 110, 125 125 125 125 225 225 225 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 225 250 250 250 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 Note: Price branch devices from page 10-19. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Circuit Breaker / Lighting and Distribution Selection Type P1 Branch Breaker Selection Breaker Type BL (120V) Available Ampere Rating 15, 20, 25, 30, 35, 40, 45, 50, 60 70 80, 90, 100 1-Pole 25. 35. — Maximum Interrupting Rating (kA) 2-Pole 3-Pole Provisions for Future $ 120V 120/240V 240V 277V 480/277V 45. 85. 140. 140. 190. 210. — — — 10 10 — — — List Price $ Installed BL (HID) 15, 20, 30 40. 70. — — — — — — — BLH (120V) 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 70 80, 90, 100 35. 75. — 85. 130. 200. 220. 300. 310. — — — 22 22 — — — HBL 15, 20, 30, 40, 50 60, 70, 80, 90, 100 65. — 150. 400. 290. 480. — — 65 65 BLF (GFCI) 15, 20, 30 40, 50, 60 140. — 240. 250. — — — — 10 — — — — BLE (EQGFI) 15, 20, 30 220. 330. — — 10 — — — — BLEH 15, 20, 30 40, 50, 60 (2-Pole Only) 420. — 530. 530. — — 22 22 — — — BGL (SWN) 15, 20, 30 15, 20, 30 — — 100. — — 120. — — 10 10 — — — BAF 15, 20 160. 330. — — 10 — — — — BAFH 15, 20 180. 340. — — 22 — — — — BLR (240V) 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 70, 80, 90, 100 — — 110. 190. — — — — 10 10 — — BLHF (GFCI) 15, 20, 30 40, 50, 60 160. — 280. 300. — — — — 22 22 — — BQD 15, 20, 30, 40, 50, 60 70, 80, 90, 100 85. 200. 270. 400. 380. 490. — — 65 65 65 14 14 15, 20, 30, 40, 50, 60 70, 80, 90, 100, 110, 125 130. 210. — 360. 420. 710. 480. 540. 910. — — — 100 100 100 25 25 NGB 65 10 — Subfeed Breakers — Limit One Per Panel Maximum Interrupting Rating (kA) 3-Pole Provisions for Future $ 120V 120/240V 670. 1120. 120. 120. — — — — 65 65 690. 1260. 770. 1460. 120. 120. — — — — 100 100 — — 1270. 1270. 1400. 1400. 120. 120. — — — — 100 100 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 — 420. 880. 170. — — 10 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 — 930. 1140. 170. — — 22 QJ2H 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 — 1080. 1410. 170. — — 42 HQJ2H FXD6 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 — — 1940. 170. — — 100 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250 — 1220. 1540. 220. — — 65 HFD6 70, 80, 90, 100, 125, 150, 175, 200, 225, 250 — 2440. 2550. 220. — — 100 Available Ampere Rating List Price $ Installed ED4 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 110, 125 — — 520. 880. HED4 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 110, 125 — — HHED6 15, 20, 30, 40, 50, 60, 70 80, 90, 100, 110 QJ2 QJH2 Breaker Type 1-Pole 2-Pole 240V Note: BGL Breaker — 1-pole takes 2" unit space or 2-poles — 2-pole takes 3" unit space or 3-poles Note: 1-pole HBL limited to 50 amps 10 PANELBOARDS Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-19 Panelboards Type 1 P1 Panelboard Modifications and Additions Enclosures List Price $ Description 6" end gutter . . . . . . . . . . . . . . . . . . . . . 2" side gutter . . . . . . . . . . . . . . . . . . . . . Barrier in gutter (add to extra gutter price) . . . . . . . . . . . . . . . . . . . . 24" wide . . . . . . . . . . . . . . . . . . . . . . . . . 235. 200. Hinged trims . . . . . . . . . . . . . . . . . . . . . Piano hinged trims . . . . . . . . . . . . . . . . Door-in-door trims . . . . . . . . . . . . . . . . Screw to the box trims . . . . . . . . . . . . . 160. 360. 360. 160. 200. 235. Trim mounted devices . . . . . . . See page 10–72 • Pilot lights • Toggle switches • Push buttons (Devices mounted to be wired to the trim should also have hinged trim specified) Painted boxes . . . . . . . . . . . . See page 10–72 Custom colors . . . . . . . . . . . See painted boxes Increase gauge trims and boxes . . . . . . . . . . . . . See page 10–72 Stainless steel trims and boxes, Type 1 . . . . . . See page 10–72 Aluminum trims and boxes, Type 1 . . . . . . See page 10–72 Meters (Contact sales for pricing and application engineering for space requirements) Panel Skirts See page 10-73 Special Locks TEY . . . . . . . . . . . . . . . . . . . . . . . . . . . TEU1 . . . . . . . . . . . . . . . . . . . . . . . . . . Cat 60 . . . . . . . . . . . . . . . . . . . . . . . . . LL803 . . . . . . . . . . . . . . . . . . . . . . . . . LL806 . . . . . . . . . . . . . . . . . . . . . . . . . Yale 47 (NYC) . . . . . . . . . . . . . . . . . . . 235. 255. 235. 235. 235. 425. Panel Modifications Main Bus Catalog Amp Ratings Number* 125A 250A 400A Copper (tin pltd.) C 390. 255. 255. * “C” represents “A” in the 11th digit of the catalog number. Branch and Main Breaker and Accessories Bus mounted TVSS . . . . . see section 9 Service Entrance Label Type P1 Panelboards are factory labeled suitable for use as service entrance equipment when NEC requirements are met. A panelboard cannot have more than six main disconnects, unless it is a lighting and appliance branch panelboard. Lighting and appliance branch panelboards are limited to two main disconnects. Grounding of Panelboards Ground Bars except for brazed to box are shipped with the panel interior factory mounted. • Non-Insulated Equipment Ground Bar – STD • Copper Non-Insulated Ground Bar . . . . . . 40. • Al Insulated Equipment Ground Bar. . . . . 40. • Cu Insulated Equipment Ground Bar . . . . 75. • Ground Bar Brazed to Box . . . . . . . . . . . 245. (recommended for painted boxes) Shunt Trip on Main or Branch BL, BLH, HBL, BQD as branch only. BL, BLH, HBL uses 1" unit space for shunt trip as a branch device. All others may be used on mains or subfeeds. See breaker section for list price adders. QJ2, QJ2-H, QJH2, HQJ2H, ED4, ED6, HED4, HED6, HHED6, FXD6, HFD6, JXD6, JD6, HJD6, HJXD6 Application for Remote Switch Switch Type 920 911 LEN Modification Mounts in 23" relay cabinet as a main only ≤ 150 AMPS mounts in 23" relay cabinet as a main only >150 AMPS not available 30A mounts in 23" relay cabinet as a main only Feed-Thru Lugs Cannot be used in conduction with TVSS or subfeed breakers Ampere List Rating Price $ Type Al/Cu Lay-in 190. Mechanical Cu Lay-in 250 370. Mechanical Al/Cu 285. Compression Al/Cu 490. AWG Mechanical 400 775. Cu 585. Al/Cu Compression Connector Range (1)—#6 AWG350 kcmil (1)—#6 AWG350 kcmil (1)—#6 AWG350 kcmil (2)—#3/0 AWG250 kcmil or (1)—#3/0 AWG600 kcmil (2)—#3/0 AWG250 kcmil or (1)—#3/0 AWG600 kcmil (1) 400—600 kcmil Note: Specify copper or aluminum cable. Remote Control Switches 480V AC max. mounted in a 23" enclosure to be cable connected to the panel. Time Clocks Time clocks may be mounted in a 23" enclosure to be cable connected to the panel. Sangamo, Tork or Paragon time clock can be supplied. Description Time Clock (1 or 2-pole, single or double throw contacts; 3-pole, single throw) 277V maximum with plain dial Astronomical dial An omitting device Reserve power or carryover Space and mounting provisions only List Price $ 1070. 210. 75. 2450. 540. Remote Switches Modifications (See page 10-71) PANELBOARDS 10 See breaker section for pricing on the following options • Handle blocks • Handle locks • Aux. Contacts햲 • UVR햲 Selection 햲 Accessories on 1" pole breakers (BL, BQD, ED) will take unit space. 10-20 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P1 Panelboard Connector Modifications Selection Compression Lugs Style Amp Rating 125 MLO 250 400 Compression Connectors Box Height Addition N/A (1) #4 AWG - 350 kcmil None 105. 105. 105. 105. N/A (1) 250-600 kcmil or None 150. 150. 150. 150. (1) #12-1/0 AWG Box must go to 24" wide 115. 85. 85. 85. (2) #3/0 AWG - 250 kcmil 125 Main Breaker List Price Adder $ 3-Phase/ 3-Phase/ 1-Phase/ 1-Phase/ 4-Wire 3-Wire 3-Wire 2-Wire Breaker Type ED4, ED6, HED4 HHED6, CED6 225 QJ2, QJH2, QJ2H (1) #6 AWG - 350 kcmil Cu or AI Box must go to 24" wide for all breakers 225. 180. 180. 180. 250 FXD6, HFD6, CFD6 (1) #6 AWG - 350 kcmil Cu or AI Box must go to 24" wide for all breakers 225. 180. 180. 180. NOTE: Standard compression lugs used for P1 panels are range taking lugs and may require a particular crimping tool to accommodate the range. Consult factory for information. 200% neutral not available with compression lugs. Enclosure Modifications List Price Adder $ Description NEMA 3R enclosure s NEMA 3R/12 enclosure s Gasket between trim and box (Type 1) Panel Width 20" Panel Width 24" 860. 1175. 680. 1180. 1180. 900. NEMA-4—Water Tight, Dust Tight, Steel Enclosure (consult plant for actual enclosure size) Box Height (inches) Enclosure Size H W D List Price Adder $ 32 38 44 56 62 68 32 38 44 56 62 68 5.75 5.75 5.75 5.75 5.75 5.75 4230. 5330. 6605. 16260. 17500. 19025. 20 20 20 20 20 20 Additional Enclosure Modifications Description Strip Heaters List Price $ 895. Humidstat Control 1570. Thermostat Control 1570. NEMA-4X—Water Tight, Dust Tight and Corrosion Resistant (consult plant for actual enclosure size) Box Height (inches) 32 38 44 56 62 68 Enclosure - Stainless Steel & Steel with Epoxy Coating H W D 32 20 5.75 38 20 5.75 44 20 5.75 56 20 5.75 62 20 5.75 68 20 5.75 Enclosure - Fiberglass Size (inches) H D W 36 24 8 48 36 12 48 36 12 60 36 12 66 36 12 72 36 12 List Price $ 10145. 12085. 15805. 20265. 23710. 27435. 10 Remote Switches Modifications (See page 10-71) Switch Type 920 911 LEN PANELBOARDS Application for Remote Switch Modification Mounts in 23" relay cabinet as a main only ≤ 150 AMPS mounts in 23" relay cabinet as a main only >150 AMPS not available 30A mounts in 23" relay cabinet as a main only Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-21 Panelboards Type P1 Dimensions Type 1 Box Box is symmetrical Box To Wall Mounting Holes 2 in. [ 51 ] .31 in. [8] 4.63 in. [ 118 ] Mounting Dimple Interior To Box Mounting Stubs 햲 32 in., 38 in., 44 in. [ 813 ] [ 965 ] [ 1118 ] 56 in., 62 in., 68 in. [ 1422 ] [ 1574 ] [ 1727 ] 4.63 in. [ 118 ] 12.63 in. [ 321 ] 15 in. [ 381 ] 5.75 in. [ 146 ] 2 in. [ 51 ] 햲 20 in. [ 508 ] 햲 Type 3R and 3R/12 Box 7.5 in. [ 191 ] .50 in. [ 13 ] 2 in. [ 51 ] Mounting Bracket 32 in., 38 in., 44 in. [ 813 ] [ 965 ] [ 1118 ] 햲 56 in., 62 in., 68 in. [ 1422 ] [ 1574 ] [ 1727 ] 2 in. [ 51 ] 2 in. [ 51 ] 20 in. 햲 [ 508 ] 1 in. [25] 10 21.5 in. [ 546 ] 5.75 in. [ 146 ] 햲 PANELBOARDS 23.5 in. [ 597 ] 햲 Dimensions are interior of the box. Add 5/8" to width for absolute dimension. Add 1/8" to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. 10-22 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Panelboards Type P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factoryassembled options to meet almost all lighting panel applications. With this design, the ability to mix breaker frames in unit space up to 250 amps will also meet many distribution panel requirements in a much smaller package. Bussing options for the P2 vary from the typical temperature rated to 750 A/Si aluminum to 1000A/Si copper. Standard bussing in the P2 panel is tin-plated. Silver-plated copper is also offered as an option. Integrated time clocks, bus mounted contactors, as mains or sub mains, split bus, and subfeed lugs (up to 400 amp) are just a few of the options of this unique panel. Like a lighting panel, P2 is set up around 18, 30, 42, and 54 circuit configurations. It will also allow the user to configure the panel to the smallest possible size. The P2 panel starts with 9" of unit space (18 circuits of 1" pole breakers). Breakers mounted in unit space can be mixed and matched to meet customer requirements. All 1" pole breakers (BL, BQD, ED frames) are mounted in 3" or 6" pole increments. Breaker frames, above 125 amps, are mounted in 6" single breaker mountings. General As an example of a minimum panel, (6) 20 amp 1-pole BL breakers (3" of unit space) and a 3-pole 225 amp QJ breaker (6" of unit space) equaling 9" of unit space can be configured in a P2 panel without any extra provisions or space required. FD 250 amp and JD 400 amp breakers are mounted as subfeed breakers outside of unit space. Another unique feature of the P2 panel is that blank unit space can be added to allow for future expansions or modifications. Any expansions or modifications must be in 3" increments. BL, BQD, and ED frame breakers have 3" or 6" pole kits, and can be mixed in unit space by these increments. Breakers of the same frame can cross from one mounting to another if contiguous. QJ frame breakers are mounted in 6" increments for two- and three pole, single mounted units. Changes in the unit space length for BL, BQD, or ED frame breakers require an addition deadfront, center strip kit. Check with sales or the factory for additional unit space kits. Main Lug / Main Breaker Enclosure – Standard Type 1 enclosure is 20" wide x 5.75" deep X. Box Height is determined by main device and unit space. See charts for box height. Voltage – 600V AC max. 250V DC max. Amperage – 600 amp max. Short circuit rating – 200 KAIC max. symmetrical or equal to the lowest rated device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to a three-cycle rating. The three-cycle rating for the P2 panel is limited to 22 KAIC. Note that the main device may be mounted remote from the panel. Bussing – The P2 panel has more options to meet market requirements. The standard bussing is temperature rated aluminum. The rating is per the requirements of UL 67 – the standard for panelboards. All aluminum bussing is tin-plated. Optional bussing for the P2 panel is: 750 A/Si aluminum, temperature rated copper, and 1000 A/Si copper. The copper bus option for this panel is tin-plated. Weight – Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is about 3 lbs. (1 kg) per inch (54g per mm) of box height. Gauge Steel of Boxes Fronts, Surface and Flush Dimensions in inches (mm) Width Height Gauge Steel Box Front 20 (508) 26–74 (660–1880) #16 #14 10 PANELBOARDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-23 Panelboards Type P2 Panelboards Selection/Dimensions Panel Unit Space To Box Height Requirements (See wire bending space diagrams below for ”A” and ”B” dimension references) P2 Panels With Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension “B” Dimension Box Height 26 32 38 44 50 56 62 68 74 Main Lugs Main Breakers 125A 250A 400A 600A 125A Horiz. BL, BQD, ED 125A Horiz. CED 125A Vert. ED 225A Horiz. QJ 250A Horiz. FD 250A Vert. CFD 400A JD 400A CJD 600A LD 600A CLD 9 15 21 27 33 39 45 51 57 — 9 15 21 27 33 39 45 51 — — 9 15 21 27 33 39 45 — — 9 15 21 27 33 39 45 9 15 21 27 33 39 45 51 57 — 9 15 21 27 33 39 45 51 — 9 15 21 27 33 39 45 51 — 9 15 21 27 33 39 45 51 — — 9 15 21 27 33 39 45 — — — — 9 15 21 27 33 — — — — 9 15 21 27 33 — — — — — — 9 15 21 — — — — — 9 15 21 27 — — — — — — 9 15 21 Main Breaker Panel Amps 100 125 225 250 400 600 Main Lug Connectors Breaker Frames C D Panel Amps Standard Connectors C D BL BQD NGB ED QJ FD JD LD 5.75 5.125 4.625 4.00 5.00 5.00 14.00 15.50 8.00 8.00 8.00 8.00 7.00 7.00 25.00 23.00 125 250 (1) #14 - 2/0 (1) #6 AWG - 350 kcmil (1) #4 AWG - 600 kcmil or (2) #6 - 250 kcmil (2) #4 AWG - 500 kcmil 6.62 12.34 8.19 11.22 14.00 13.09 14.00 11.00 Main breaker wire bending space diagram 400 600 Main lug wire bending space diagram Branch Breaker Side Gutters Inches (mm) Reference Letter A B C D햲 E 햲 Panel Width 20" (508) 5.750 (146) 5.125 (130) 4.000 (102) 5.000 (127) 4.625 (117) Single branch mounting construction. Branch breaker wire bending space diagram A B C D Box depth = 5.75 in. (146 mm) Box width – 20 in. (508 mm) for 100-600A Box depth = 5.75 in. (146 mm) Box width – 20 in. (508 mm) for 100-600A E BL, BLH, HBL BL, BLH, HBL BLF, BLFH BLF, BLFH BQD, BQD6 BQD, BQD6 ED, ED4, ED6 ED, ED4, ED6 HED4, HHED6 HED4, HHED6 QJ2, QJH2, QJ2-H, HQJ2H (Single Mounted) NGB NGB Panel Width 20 in. (508 mm) PANELBOARDS 10 Branch Breaker Side Gutters 10-24 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog A B C E Panelboards Type P2 Panelboards Selection Main Breaker Selection Ampere Rating Breaker Type 100 BL HBL BQD BLH ED4 NGB ED6 HED4 HHED6 CED6 125 Maximum Interrupting Rating (kA) List Price Adder $ 480V 600V 480V 600V Available Trip Values 10 65 65 22 65 100 100 100 100 200 — — 14 — 18 25 25 42 65 200 — — — — — — 14 — 18 100 BL HB BQ BH E4 NB E6 H4 HA CE STD 400. 400. 65. 330. 250. 360. 540. 540. 1960. — — STD (480/277) — 330. 55. 360. 540. 540. 1960. — — — — — — STD — 540. 1960. 15, 15, 15, 15, 15, 15, 15, 15, 15, 15, NGB ED4 ED6 HED4 HHED6 CED6 100 65 65 100 100 200 25 18 25 42 65 200 — — 18 — 18 100 NB E4 E6 H4 HA CE STD 55. 360. 540. 540. 1960. STD 55. 360. 540. 540. 1960. — — STD — 540. 1960. 110, 125 125 125 125 125 125 QJ2 QJH2 QJ2H HQJ2H 10 22 42 100 — — — — — — — — QJ QH Q2 Q3 STD 70. 160. 1360. — — — — — — — — 60, 60, 60, 60, 70, 70, 70, 70, FD6 FXD6 HFD6 HFXD6 CFD6 65 65 100 100 200 35 35 65 65 200 18 18 25 25 100 FD FX HF H2 CF 190. 190. 1900. 1900. 2770. STD STD 1900. 1900. 2770. STD STD 1900. 1900. 2770. 70, 70, 70, 70, 70, 80, 80, 80, 80, 80, 250 FD6 FXD6 HFD6 HFXD6 CFD6 65 65 100 65 200 35 35 65 35 150 18 18 35 25 100 FD FX HF H2 CF STD STD 1680. 1680. 1895. STD STD 1680. 1680. 2450. STD STD 1680. 1680. 2610. 250 250 250 250 250 400 JXD6 JD6 HJXD6 HJD6 SJD6 SHJD6 CJD6 SCJD6 65 65 100 100 65 100 200 200 35 35 65 65 35 65 200 200 25 35 35 35 25 35 100 100 JX J6 H6 H5 SJ S2 CJ SC STD STD 1825. 1825. 2200. 2500. 2650. 4385. STD STD 1825. 1825. 2200. 2500. 2650. 4385. STD STD 1825. 1825. 2200. 2500. 2650. 4385. 200, 200, 200, 200, 200, 200, 200, 200, 225, 225, 225, 225, 300, 300, 300, 300, 250, 250, 250, 250, 400 400 400 400 600 LXD6 LD6 HLXD6 HLD6 SLD6 SHLD6 CLD6 SCLD6 65 65 100 100 65 100 200 200 35 35 65 65 35 65 150 150 25 25 35 35 25 35 100 100 LX L6 HL HO SL S6 CL C6 STD STD 1825. 1825. 2500. 4325. 3830. 5130. STD STD 1825. 1825. 2500. 4325. 3830. 5130. STD STD 1825. 1825. 2500. 4325. 3830. 5130. 450, 250, 250, 250, 300, 300, 300, 300, 500, 300, 300, 300, 400, 400, 400, 400, 600 350, 350, 350, 500, 500, 500, 500, 225 240V Ref. Catalog Number 240V 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 30, 30, 30, 30, 30, 30, 30, 30, 30, 30, 35, 35, 35, 35, 35, 35, 35, 35, 35, 35, 40, 40, 40, 40, 40, 40, 40, 40, 40, 40, 80, 80, 80, 80, 90, 90, 90, 90, 100, 100, 100, 100, 90, 90, 90, 90, 90, 100, 100, 100, 100, 100, 110, 110, 110, 110, 110, 110, 110, 110, 110, 300, 300, 300, 300, 50, 50, 50, 50, 50, 50, 50, 50, 50, 50, 125, 125, 125, 125, 125, 125, 125, 125, 125, 350, 350, 350, 350, 60, 60, 60, 60, 60, 60, 60, 60, 60, 60, 70, 70, 70, 70, 70, 70, 70, 70, 70, 70, 80, 80, 80, 80, 80, 80, 80, 80, 80, 80, 150, 150, 150, 150, 150, 150, 150, 150, 150, 90, 100 90, 100 90, 100 90, 100 90, 100 100 90, 100 90, 100 90, 100 90, 100 175, 175, 175, 175, 175, 175, 175, 175, 175, 200, 200, 200, 200, 200, 200, 200, 200, 200, 225 225 225 225 225 225 225 225 225 400 400 400 400 400, 450, 500, 600 400, 450, 500, 600 400, 450, 500, 600 600 600 600 600 When an ED4, ED6, HED4, QJ2, QJH2, QJ2H, FD6, HFD6, or FXD6 frame main breaker, vertically mounted, is required, price as a main breaker panel and add from the table for the main breaker mounting. Vertically Mounted Main Breaker Ampere Rating 100 225 Breaker Type(s) Number of Poles 2-Pole 3-Pole 295. 295. 295. 320. 320. 320. QJ2, QJH2, QJ2-H FXD6, FD6, HFD6 390. 625. 415. 670. 6 6 10 ED4 ED6 HED4 Unit Space (in.) Subfeed Breakers Provisions for Future $ FD6 , FXD6 Ampere Ratings For Load Maximum Interrupting Rating (kA) Symmetrical 240V AC 480V AC 600V AC Twin 1220. 1540. 220.-- 70 – 250 65 35 HFD6 ,HFXD6 Twin 2440. 3010. 220.-- 70 – 250 100 65 25 JD6 , JXD6 Single 1720. 2180. 290.-- 200 – 400 65 35 25 HJD6 , HJXD6 Single 3160. 4220. 290.-- 200 – 400 100 65 35 Discount Schedule PBSB 22 Interchangeable trip main breakers are mounted at top of panel only. Vertically mounted. Twin mounted subfeed breakers are mounted at the bottom of panelboard only and adds 24" to the panel height. Subfeed breaker is mounted at bottom of panelboard only. 400 amp subfeed breaker adds 24" to the panel height. (Only for use with MLO) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-25 PANELBOARDS Breaker Type Mounting Position When Used as Subfeed Breaker List Price $ Vertical 2-Pole 3-Pole Panelboards Type P2 Panelboards Selection Branch Circuit Breakers Max. Bolt-On Amp Breaker Rating Type 100 125 225 Amps 15–60 BL 70 80–100 15–60 BLH 70 80–100 15–55 HBL 60–100 BL, HID 15–30 15–60 BLR (240V) 70–100 15–30 BLE (GFCI) 40–60 20–30 BLEH 15–60 15–30 BLF (GFCI) 40–60 15–30 BLHF (GFCI) 40–60 BGL 햳 15–30 BAF 15–20 BAFH 15–20 15–60 BQD 70–100 15–60 NGB 70–100 110–125 15–60 ED4 70–100 110–125 15–60 ED6 70–100 110–125 15–60 70–100 HED4햲 110–125 15–60 HHED6 70–100 110–125 QJ2 60–225 QJH2 60–225 QJ2H 60–225 HQJ2H 60–225 List Price $ 1-Pole 2-Pole 3-Pole 25. 35. — 35. 75. — 85. — 45. — — 220. — 420. — 140. 140. 160. 160. — 160. 180. 85. 200. 130. 210. — 160. 260. — — — — 320. 320. — — — — — — — — 45. 85. 140. 85. 130. 200. 270. 400. 75. 110. 190. 330. 330. — 530. 240. 250. 280. 300. 100. 330. 340. 270. 400. 360. 420. 710. 440. 520. 880. 460. 600. 1100. 700. 860. 1590. 700. 860. 1600. 420. 930. 1080. — 140. 190. 210. 220. 300. 310. 380. 490. — — — — — — — — — — — 130. — — 380. 490. 480. 540. 910. 590. 670. 1120. 700. 790. 1350. 880. 960. 1800. 890. 990. 1810. 880. 1140. 1410. 1940. Provisions for Future $ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 170. 170. 170. 170. Maximum Interrupting Rating (kA) 120V AC 120/240V AC 240V AC 10 — — — — — — — 10 — — 10 — 22 — 10 — 22 — 10 10 22 — — 100 100 100 65 — — — — — — — — — — — — — — — 277V AC — — 10 — — 22 — — — 10 10 — — — — — — — — — — — — — 100 100 100 — 65 65 65 65 65 65 65 65 100 100 100 10 22 42 100 — — — — — — — — — — — — — — — — — — — — — — 14 — 25 25 25 22 — — — — — — — — 65 42 — — — — — 480V AC — — — — — — — — — — — — — — — — — — — — — — — 14 25 25 25 — 18 18 25 25 25 25 25 25 — 42 42 — — — — 600V AC — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 18 18 18 18 18 18 — — — — — — — 250V DC — — — — — — — — — — — — — — — — — — — — — — 14 14 14 14 14 — 30 — 30 — — 30 — — — 30 — — — — — Branch Neutral Connections Wire Range Max. Number of Connections Max. Amp햴 #14-#6 #14-1/0 #6-350 kcmil (1) #4-600 kcmil or (2) #6-250 kcmil 26 28 3 65 125 250 1 400 PANELBOARDS 10 Branch Device Limitations For panels applied on systems requiring neutral connections, some limitations apply. By application rule (NEC 408.14) lighting and appliance panels are limited to 42 circuits installed. Each overcurrent device pole counts as a circuit. Additional limitations for these panels are based on available neutral connections. — 10 — 22 22 — 65 65 10 — — — 10 — 22 — 10 — 22 10 — — 65 65 100 100 100 — — — — — — — — — — — — — — — — 햲 1-Pole HED 4 15–30A Rated 65kA 35 through 100A Rated 25kA. Two pole breaker is one phase and neutral. Three pole is two phase and neutral. 햴 Based on 75 degree copper. NOTE: QJ Breakers are single mounted in unit space and take 6" of unit space. Limited to (4) per panel max. BL, HBL, BLH and BQD breakers are mounted in common mountings in 3" or (6) pole increments. ED4, ED6, HED4 and HHED6 breakers are mounted in common mountings in 3" or (6) pole increments. 햳 10-26 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P2 Panelboards Selection Typical Catalog Numbers Main Lugs Only Maximum Panel Amp Rating 125 250 400 600 Maximum 1-Pole Circuits Box Height inches (mm) Catalog Number 3Ø4W 208Y/120V List Price $ Catalog Number 1Ø3W 120/240V List Price $ Catalog Number 3Ø4W 480Y/277V List Price $ 18 30 42 18 30 42 18 30 42 54 18 30 42 54 26 (660) 32 (813) 38 (965) 32 (813) 38 (965) 44 (1118) 38 (965) 44 (1118) 50 (1270) 56 (1422) 38 (965) 44 (1118) 50 (1270) 56 (1422) P2C18ML125ATS P2C30ML125ATS P2C42ML125ATS P2C18ML250ATS P2C30ML250ATS P2C42ML250ATS P2C18ML400ATS P2C30ML400ATS P2C42ML400ATS P2C54ML400ATS P2C18ML600ATS P2C30ML600ATS P2C42ML600ATS P2C54ML600ATS 940.00 1140.00 1360.00 990.00 1200.00 1420.00 1350.00 1550.00 1780.00 1970.00 1630.00 1840.00 2070.00 2260.00 P2A18ML125ATS P2A30ML125ATS P2A42ML125ATS P2A18ML250ATS P2A30ML250ATS P2A42ML250ATS P2A18ML400ATS P2A30ML400ATS P2A42ML400ATS P2A54ML400ATS P2A18ML600ATS P2A30ML600ATS P2A42ML600ATS P2A54ML600ATS 840.00 1060.00 1250.00 910.00 1100.00 1330.00 1240.00 1440.00 1710.00 1800.00 1580.00 1780.00 1950.00 2140.00 P2E18ML125ATS P2E30ML125ATS P2E42ML125ATS P2E18ML250ATS P2E30ML250ATS P2E42ML250ATS P2E18ML400ATS P2E30ML400ATS P2E42ML400ATS P2E54ML400ATS P2E18ML600ATS P2E30ML600ATS P2E42ML600ATS P2E54ML600ATS 990.00 1270.00 1550.00 1090.00 1380.00 1630.00 1350.00 1550.00 1780.00 1970.00 1630.00 1840.00 2070.00 2260.00 26 (660) 32 (813) 38 (965) 26 (660) 32 (813) 38 (965) 32 (813) 38 (965) 44 (1118) 38 (965) 44 (1118) 50 (1270) 50 (1270) 56 (1422) 62 (1575) 68 (1727) 56 (1422) 62 (1575) 68 (1727) 74 (1727) P2C18BL100ATS P2C30BL100ATS P2C42BL100ATS P2C18NB125ATS P2C30NB125ATS P2C42NB125ATS P2C18QJ225ATS P2C30QJ225ATS P2C42QJ225ATS P2C18FX250ATS P2C30FX250ATS P2C42FX250ATS P2C18JX400ATS P2C30JX400ATS P2C42JX400ATS P2C54JX400ATS P2C18LX600ATS P2C30LX600ATS P2C42LX600ATS P2C54LX600ATS 1270.00 1510.00 1810.00 1710.00 1920.00 2190.00 2590.00 2800.00 3020.00 2990.00 3200.00 3430.00 3490.00 3710.00 4850.00 5080.00 6320.00 6550.00 6780.00 7000.00 P2A18BL100ATS P2A30BL100ATS P2A42BL100ATS P2A18NB125ATS P2A30NB125ATS P2A42NB125ATS P2A18QJ225ATS P2A30QJ225ATS P2A42QJ225ATS P2A18FX250ATS P2A30FX250ATS P2A42FX250ATS P2A18JX400ATS P2A30JX400ATS P2A42JX400ATS P2A54JX400ATS P2A18LX600ATS P2A30LX600ATS P2A42LX600ATS P2A54LX600ATS 1170.00 1380.00 1600.00 1490.00 1710.00 1930.00 2140.00 2370.00 2600.00 2550.00 2780.00 3000.00 2930.00 3140.00 3370.00 3600.00 5550.00 5790.00 6010.00 6240.00 P2E18BQ100ATS P2E30BQ100ATS P2E42BQ100ATS P2E18NB125ATS P2E30NB125ATS P2E42NB125ATS P2E18FX225ATS P2E30FX225ATS P2E42FX225ATS P2E18FX250ATS P2E30FX250ATS P2E42FX250ATS P2E18JX400ATS P2E30JX400ATS P2E42JX400ATS P2E54JX400ATS P2E18LX600ATS P2E30LX600ATS P2E42LX600ATS P2E54LX600ATS 1660.00 1910.00 2450.00 1980.00 2240.00 2780.00 2770.00 3060.00 3030.00 3170.00 3470.00 3450.00 4380.00 4610.00 4850.00 5080.00 6320.00 6550.00 6780.00 7000.00 Main Circuit Breaker 100 125 225 250 400 600 18 30 42 18 30 42 18 30 42 18 30 42 18 30 42 54 18 30 42 54 10 PANELBOARDS Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-27 Panelboards Type P2 Panelboard Modifications and Additions Selection Enclosures Subfeed, Feed-Thru and Split Bus Extra Gutter to Sides or Ends of the Can Unit Ampere List Price $ Connector Space Rating 3-Pole 2-Pole Cu/Al Wire Range (inches) List Price $ Description 6" end gutter . . . . . . . . . . . . . . . . . . . . . 2" side gutter . . . . . . . . . . . . . . . . . . . . . Barrier in gutter (add to extra gutter price) . . . . . . . . . . . . . . . . . . . . 24" wide . . . . . . . . . . . . . . . . . . . . . . . . . Hinged trims . . . . . . . . . . . . . . . . . . . . . Piano hinged trims . . . . . . . . . . . . . . . . Door-in-door trims . . . . . . . . . . . . . . . . Screw to the box trims . . . . . . . . . . . . . 235. 200. 200. 235. 160. 360. 360. 160. Trim mounted devices . . . . . . . See page 10–72 • Pilot lights • Toggle switches • Push buttons (Devices mounted and wired to the trim should also have hinged trim specified) Painted boxes . . . . . . . . . . . . See page 10–72 Custom colors . . . . . . . . . . . See painted boxes Increase gauge trims and boxes . . . . . . . . . . . . . See page 10–72 Stainless steel trims and boxes, Type 1 . . . . . . See page 10–72 Aluminum trims and boxes, Type 1 . . . . . . See page 10–72 Meters (Contact sales for pricing and application engineering for space requirements) Panel Skirts See page 10-73 Special Locks TEY . . . . . . . . . . . . . . . . . . . . . . . . . . . TEU1 . . . . . . . . . . . . . . . . . . . . . . . . . . Cat 60 . . . . . . . . . . . . . . . . . . . . . . . . . LL803 . . . . . . . . . . . . . . . . . . . . . . . . . LL806 . . . . . . . . . . . . . . . . . . . . . . . . . Yale 47 (NYC) . . . . . . . . . . . . . . . . . . . 235. 255. 235. 235. 235. 425. Panel Bus Modifications Main Bus Catalog Amperes Rating Number 125A 250A 400A 750 A/SI AL. B 190. 190. 340. Copper (tin pltd.) F 340. 340. 910. 1335. Copper (silver pltd.) E 455. 455. 475. 1220. 1000 A/SI Copper (tin pltd.) G 730. 730. 1020. 2110. 1000 A/SI Copper (silver pltd.) H 600A 645. Copper MLO Only Subfeed (Double) Lugs for Main Lug Panelboards Only 100/125 85. 85. (2)—#12 AWG-2/0 kcmil 225/250 85. 85. (2)—#6 AWG-350 kcmil 400 235. 235. 3 6 (4)—250 kcmil (2)—600 kcmil 12 Feed-Thru Lugs — Cannot Be Used in Conjunction with TVSS or Subfeed Breakers 100/125 190. 160. (1)—#12 AWG-2/0 kcmil 3 225/250 190. 160. (1)—#6 AWG-350 kcmil 6 400 490. 445. (2)—250 kcmil (1)—600 kcmil 9 600 720. 680. (2)—250-500 kcmil 12 Split Bus Requires feed thru lugs also to feed sub panel section and for space requirements. 100/125 245. 180. (1)—#12 AWG-2/0 kcmil 225/250 245. 180. (1)—#6 AWG-350 kcmil 9 9 400 490. 445. (2)—250 kcmil (1)—600 kcmil 600 720. 680. (2)—250-500 kcmil 15 12 Contactor Mains or Submain See Page 10-71 • Asco 920 through 225 amps – adds 12" unit space as main, 15" unit space as submain • Asco 911 through 150 amps – adds 21" unit space • Siemens LEN through 30 amps – adds 12" unit space, makes box 10" deep Branch and Main Breaker Accessories See breaker section of this catalog. • Handle blocks • Handle locks • Aux. Contacts��� • UVR햲 1070. 1070. 1240. 2355. 10 Increase Capacity Neutral up to 200% Main Bus Amps List Price Adder $ 125 250 400 600 340. 530. 560. 625. PANELBOARDS See page 10-29 for unit space adders and compatibility with other options. 햲 Main Bus Amps List Price Adder $ 125 250 400 600 115. 190. 285. 285. Bus mounted TVSS . . . . . . see section 9 Service Entrance Label Type P2 Panelboards are factory labeled suitable for use as service entrance equipment when NEC requirements are met. A panelboard cannot have more than six main disconnects, unless it is a lighting and appliance branch panelboard. Lighting and appliance branch panelboards are limited to two main disconnects. Grounding of Panelboards Ground Bars except for brazed to box are shipped with the panel interior factory mounted. • Non-Insulated Equipment Ground Bar – STD • Copper Non-Insulated Ground Bar. . . . . . 40. • Al Insulated Equipment Ground Bar . . . . 40. • Cu Insulated Equipment Ground Bar . . . . 75. • Ground Bar Brazed to Box . . . . . . . . . . . 245. (recommended for painted boxes) Shunt Trip on Main or Branch BL, BLH, HBL, ED4, HED4, HED6, HHED6 uses 1" unit space for shunt trip. All others may be used on mains or subfeeds. See breaker section for list price adders. QJ2, QJ2-H, QJH2, HQJ2H, ED4, ED6, HED4, HED6, HHED6, FXD6, HFD6, JXD6, JD6, HJD6, HJXD6 Time Clocks Time clocks may be mounted in a 23" enclosure to be cable connected to the panel. Sangamo, Tork or Paragon time clock can be supplied and mounted in panelboard cabinet. Adds 12" to panel height. Mounts in Sub-area. List Price $ Description Time Clock (1 or 2-pole, single or double throw contacts; 3-pole, single throw) 277V maximum with plain dial Options— Astronomical dial An omitting device Reserve power or carryover Space and mounting provisions only 1070. 210. 75. 2450. 540. Subfeed Main Breaker Panels Double Lugs Ratings Amps Poles 2 100 3 2 225 3 2 400 3 Mount Ht. List Price $ 575. 21" 620. 635. 21" 670. 760. 18" 825. Accessories on 1" pole breakers (BL, BQD, ED) will take unit space. 10-28 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P2 Panelboard Standard Modifications and Additions Selection Box Size Additions for Optional Features Main Lugs Main Breakers 125A 250A 400A *Min. Box Size 200% Neutral (lug type) Std. Lugs (100% Neut. PNL) CU Lugs (100% Neut. PNL) Comp Lugs (100% Neut. PNL) Feed-thru Standard Lugs 26" 0 32" 0 0 0 0 6 6 6 Feed-thru Cu Lugs Feed-thru Comp Lugs Subfeed Standard Lugs 600A Options Split Bus (1) FD Subfeed (Horizontal Mtg.) (2) FD Subfeed (Vertical Mtg.) TVSS 125A 125A Horiz. Horiz. BL, BQD, ED, NGB CED 125A Vert. 225A Horiz. 225A Vert. 225A Horiz. 250A Vert. 250A Vert. 400A JD 400A CJD 600A LD 600A CLD 62" 0 56" 0 62" 0 ED QJ QJ FD FD 26" 0 32" 0 32" 0 32" N/A 38" 0 38" N/A 44" 0 50" 0 50" 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 N/A N/A 0 N/A 0 N/A 0 0 0 0 0 0 6 6 6 N/A N/A 0 N/A 0 N/A 0 0 0 0 0 0 6 6 12 12 6 6 6 6 6 12 N/A N/A N/A 6 N/A N/A 6 6 N/A N/A 6 6 6 6 12 12 12 12 12 N/A 12 N/A 6 12 12 N/A N/A N/A 6 N/A 6 N/A 12 12 12 12 N/A N/A 0 6 N/A 6 6 12 6 6 12 N/A 6 12 — 6 N/A — 6 N/A — 6 N/A — N/A N/A — 6 N/A — N/A 12 — 6 12 — 6 12 N/A 6 12 — 6 12 — 6 12 — 6 12 N/A 24 24 24 N/A N/A N/A N/A N/A 24 24 24 24 N/A N/A N/A 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 38" 38" 6 (all) 6 (all) CFD Split bus is paired with feed-thru lugs by default. Feed-thru lugs are to feed the section after the split. NOTE: N/A = OPTION NOT AVAILABLE *Min. Box Size, corresponding to 9" of Unit Space. Compression Lugs Style MLO Amp Rating 125 250 Breaker Type N/A N/A 400 N/A 600 N/A 225 ED4, ED6, HED4 HHED6, CED6 QJ2, QJH2, QJ2H 250 FXD6, HFD6, CFD6 100 Main Breaker Compression Connectors (1)#6 - 350 kcmil Al/Cu (1)#6 - 350 kcmil Al/Cu (1) 400 - 600 kcmil Cu or (2)#6 - 350 kcmil Al/Cu (2)#6 - 350 kcmil Cu or Cu/Al or 400 - 600 kcmil Al/Cu (1)#14-2/0 AWG Cu or Al (1)#6 AWG - 350 kcmil Cu or Al (1)#6 AWG - 350 kcmil Cu or Al JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, (2)#1/0 AWG - 500 kcmil Cu or Al SCJD6 LD6, LXD6, HLD6, CJD6, SLD6, SHLD6, (2)#2/0 AWG - 500 kcmil Cu or Al SCLD6 400 600 Box Height Addition 6 6 List Price $ 3Ø4W 3Ø3W 1Ø3W 1Ø2W 105. 75. 75. 65. 105. 75. 75. 65. 6 150. 115. 115. 95. 6 200. 150. 150. 115. 115. 85. 85. 85. 225. 180. 180. 180. 225. 180. 180. 180. 9 305. 235. 235. 235. 6 305. 235. 235. 235. Box must go to 24" wide on CED6 breaker only Add 6" to box height for NØ Box must go to 24" wide Box must go to 24" wide for all breakers Requires an additional 6.0" box height Alternate Lugs Breaker Type 400 N/A Main Breaker 400 JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, SCJD6 Discount Schedule PBSB Compression Connectors (1) 250 - 750 kcmil or (2)#3/0 AWG - 250 kcmil Cu or Al (1)#4/0 AWG - 750 kcmil Cu or Al Box Height Addition List Price $ 6 275. 6 510. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog PANELBOARDS Amp Rating MLO 10 Style 10-29 Panelboards Type P2 Panelboard Connector Modifications Selection Enclosure Modifications List Price Adder $ Description NEMA 3R enclosure s NEMA 3R/12 enclosure s Gasket between trim and box (Type 1) Panel Width 20" Panel Width 24" 860. 1175. 680. 1180. 1180. 900. NEMA-4 for Type P2 Water Tight, Dust Tight, Steel Enclosure (consult plant for actual enclosure size) Box Height Inches 26 32 38 44 50 56 62 68 74 Enclosure Size H W 26 20 32 20 38 20 44 20 50 20 56 20 62 20 68 20 74 20 D 5.75 5.75 5.75 5.75 5.75 5.75 5.75 5.75 5.75 List Price Adder $ 3920. 4230. 5330. 6605. 8015. 16260. 20545. 24835. 29340. NEMA-4X for Type P2 Water Tight, Dust Tight and Corrosion Resistant (consult plant for actual enclosure size) Box Height Inches 26 32 38 44 50 56 62 68 74 Enclosure - Stainless Steel and Steel with Epoxy Coating H W D 5.75 26 20 5.75 32 20 5.75 38 20 5.75 44 20 5.75 50 20 5.75 56 20 5.75 62 20 5.75 68 20 5.75 74 20 Enclosure - Fiberglass Size (inches) H W D 30 24 8 36 24 8 48 36 12 48 36 12 60 36 12 60 36 12 72 36 8 72 36 8 84 36 8 List Price $ 9000. 10145. 12085. 15805. 18710. 20265. 23710. 27435. 31155. Remote Switch Modifications (see page 10-71) Application For Remote Switch Switch Type 920 911 PANELBOARDS 10 LEN Modification Adds 12" to unit space ≤ 225A Adds 21" unit space >225 ≤400 Amps Add 10" to width and 8" DP minimum and 24" to height 30A Adds 15" to unit space >30A 100 Adds 12" to unit space 7.7 Dp. Box min. 100 A ≤ 200 Adds 12" to unit space and 10" Dp. min. 10-30 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P2 Panelboard Kits and Accessories Selection Standard Enclosures Catalog Number Box Height Inches 26 32 38 44 50 56 62 68 74 Type 1 Box B26 B32 B38 B44 B50 B56 B62 B68 B74 Standard Trim Surface S26B S32B S38B S44B S50B S56B S62B S68B S74B Flush F26B F32B F38B F44B F50B F56B F62B F68B F74B Type 3R NR26 NR32 NR38 NR44 NR50 NR56 NR62 NR68 NR74 Type 3R/12 WP26 WP32 WP38 WP44 WP50 WP56 WP62 WP68 WP74 Options For Type 1 Trims Items must be ordered as manual line item on Spartanburg Hinged trim – Replace “B” suffix with “H” Door-in-door – Replace “B” suffix with “D” Metal card holder – Replace “B” suffix with “M” on standard trim, add “M” suffix on optional trims Option For 24" Wide Enclosures with Equal Gutter on Both Sides 24" wide with equal gutter on both sides - Add “24” as prefix Breaker Kits and Accessories Kit Number BBKB32 BBKED32 Description BL/BQD 6-pole 3" branch breaker kit ED 6-pole 3" branch breaker kit BBKNB32 BBKQ1 NGB 6-pole 3" branch breaker kit QJ branch breaker kit for 2 and 3-pole single mount BL, BQD, ED deadfront kit for 1" pole breakers Deadfront filler 3" Deadfront filler 6" Branch neutral (P2) P2 250A max. Bonding Kit P2 400A max. Bonding Kit P2 600A max. Bonding Kit DFK1 DFFP3 DFFP6 BNK2 P2BK1 P2BK2 P2BK3 Contents Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit contains breaker support, inter-phase barriers, (3) A/C connectors, (1) B connector, hardware Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit to contain all connectors and cover plates necessary to mount both 2 and 3-pole breakers Center strips 3", 6", 9," 15," 21" plus mounting hardware 3" empty space filler and hardware 6" empty space filler and hardware Three tier lug with mounting hardware to increase neutral capacity Bonding strap and hardware Bonding strap and hardware Bonding strap and hardware List Price $ 85.00 90.00 90.00 102.00 90.00 45.00 51.00 45.00 23.00 23.00 23.00 10 PANELBOARDS Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-31 Panelboards Type P2 Panelboards Type 1 Box Box is symmetrical Dimensions Box To Wall Mounting Holes 2 in. [ 51 ] .31 in. [8] 4.63 in. [ 118 ] Mounting Dimple Interior To Box Mounting Stubs 26 in. 32 in. 38 in. 44 in. 50 in. 햲 [ 660 ] [ 816 ] [ 965 ] [ 1118 ] [ 1270 ] 56 in. 62 in. 68 in. 74 in. [ 1422 ] [ 1575 ] [ 1727 ] [ 1880 ] 4.63 in. [ 118 ] 12.63 in. [ 321 ] 15 in. [ 381 ] 5.75 in. [ 146 ] 2 in. [ 51 ] 햲 20 in. [ 508 ] 햲 Type 3R and 3R/12 Box 7.5 in. [ 191 ] .50 in. [ 13 ] 2 in. [ 51 ] Mounting Bracket 26 in. 32 in. 38 in. 44 in. 50 in. 햲 [ 660 ] [ 816 ] [ 965 ] [ 1118 ] [ 1270 ] 56 in. 62 in. 68 in. 74 in. [ 1422 ] [ 1575 ] [ 1727 ] [ 1880 ] 2 in. [ 51 ] 2 in. [ 51 ] 10 20 in. 햲 [ 508 ] 1 in. [25] PANELBOARDS 21.5 in. [ 546 ] 23.5 in. [ 597 ] 10-32 5.75 in. [ 146 ] 햲 햲 Dimensions are interior of the box. Add 5/8" to width for absolute dimension. Add 1/8" to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Panelboards Type P3 Panelboards Features Another innovation from Siemens is the P3 panel. It is a smaller, footprint distribution panel to fit a large number of applications that require more (or larger) branch devices than the lighting panel class offer. This panel offers a wide array of factory-assembled options, and has the ability to mix breaker frames in unit space up to 250 amps. Bussing options for the P3 vary from the standard temperature aluminum to temperature rated copper, 750 A/Si aluminum, and 1000A/Si copper designs. All bussing in the P3 panel is tin-plated as a standard. Silver-plated copper is offered as an option on a copper bus. Integrated time clocks, bus mounted contactors, as mains or sub mains, split bus and subfeed lugs (up to 400 amp) are just a few of the options of this unique panel. The P3 panel configurations, defined by the unit space, allow for a given amperage, main device, and box height. The P3 panel starts with a 56" high box. Breaker unit space can be mixed and matched to meet customer requirements. All 1" pole breakers (BL, BQD, ED frames) are mounted in 3" or 6" pole increments. Breakers frames, above 125 amps, are mounted in 6" single or twin breaker mountings. As an example panel, FD 250 amp and JD 400 amp breakers are mounted as subfeed breakers outside of unit space. Like other distribution panels, the P3 panel can have blank space added into the panel to allow for future expansions or modifications. Any expansions or modifications must be in 3" increments. BL, BQD and ED frame breakers have 3" or 6-pole kits and can be mixed in unit space by these increments. Breakers of the same frame can cross from one mounting to another if contiguous. QJ frame breakers are mounted in 6" increments for two and three pole single and twin mounted units. Changes in the unit space length for BL, BQD, or ED frame breakers require an additional deadfront center strip kit. Check with sales or the factory for additional unit space kits. General Main Lug/Main Breaker Enclosure – Standard Type 1 enclosure is 24" wide x 7.75" deep. X Box Height is determined by main device and unit space. See charts for box height. Voltage – 600V AC max. 250V DC max. Amperage – 800 amp max. Short Circuit Rating – 200 Kaic max. symmetrical or equal to the lowest rated device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to a three-cycle rating. The three-cycle rating for the P3 panel is limited to 22 Kaic. Note that the main device may be mounted remote from the panel. Bussing – The P3 panel has more options to meet market requirements. The standard bussing is temperature rated aluminum. The rating is per the requirements of UL 67 – the standard for panelboards. All aluminum bussing is tin-plated. Optional bussing for the P3 panel is: 750 A/si aluminum, temperature rated copper, and 1000 A/si copper. The copper bus option for this panel is tin-plated. Weight – Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is about 5 lbs. (1 kg) per inch (54g per mm) of box height. Gauge Steel of Boxes Fronts, Surface & Flush Dimensions Width 24" (610) in inches (mm) Height 56 - 80" (1422, 2032) Gauge Steel Box Front #16 #14 10 PANELBOARDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-33 Panelboards Type P3 Panelboards Selection/Dimensions Panel Unit Space To Box Height Requirements “B” Dimension Box Height P3 Panels With Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension Main Lugs Main Breakers 250A 250A Horiz. Vert. 250A 400A 400A 250A 400A 600A 800A FD FD CFD JD CJD 600A LD 600A CLD 56 62 68 74 80 27 33 39 45 51 9 15 21 27 33 — 9 15 21 27 C 10.75 ��� 16.00 D 13.50 17.88 16.00 16.00 17.88 17.88 21 27 33 39 45 21 27 33 39 45 21 27 33 39 45 21 27 33 39 45 15 21 27 33 39 C 7.25 — — — — — — 9 15 21 27 33 — 9 15 21 27 Main Lug Wire Bending Main Breaker Wire Bending Breaker Frame FD Horiz. FD Vert. CFD JD CJD LD CLD 9 15 21 27 33 E — 12.25 13.63 15.63 14.75 14.75 14.00 Panel Amps 250 400 F 20.13 25.38 31.38 29.38 35.38 29.38 35.38 600 800 햲 Standard Connectors (1) #6 AWG - 350 kcmil (2) #3/0 AWG - 250 kcmil or (1) 600 kcmil (2) #3/0 AWG - 500 kcmil (2) 600 kcmil This lug is removable. Main Lug Wire Bending Diagram Main Breaker Wire Bending Diagram Branch Breaker Side Gutters Inches (mm) Reference Letter Panel Width 24" (609) A B C D��� E F G 7.750 7.125 6.000 7.000 5.000 6.625 5.750 햲 (197) (181) (152) (178) (127) (168) (144) Single branch mounting construction. Branch Breaker Wire Bending Diagram A B Box depth = 7.75 in. (197 mm) Box width = 24 in. (610 mm) Main Breaker Wire Bending C D/E F G BL, BLH, HBL BL, BLH, HBL BLF, BLFH BLF, BLFH BQD, BQD6 BQD, BQD6 ED, ED4, ED6 ED, ED4, ED6 HED4, HHED6 HED4, HHED6 QJ2, QJH2, QJ2, QJH2, QJ2-H, HQJ2H QJ2-H, HQJ2H NGB NGB NEB, HEB NEB, HEB A B C D/E F G Panel Width 24 in. (610 mm) PANELBOARDS 10 Branch Breaker Side Gutters 10-34 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Box depth = 7.75 in. (197 mm) Box width = 24 in. (610 mm) Main Lug Wire Bending Panelboards Type P3 Panelboards Selection Alternate Main Breakers 햲 Maximum Interrupting Rating (kA) 240V 480V 600V Ref. Catalog Number 250 FD6 FXD6 HFD6 HFXD6 CFD6 햲 65 65 100 100 200 35 35 65 65 150 18 18 25 25 100 FD FX HF H2 CF STD STD 1900. 1900. 2770. STD STD 1900. 1900. 2770. STD STD 1900. 1900. 2770. 70, 70, 70, 70, 70, 400 JXD6 햲 JD6 햲 HJXD6 햲 HJD6 햲 SJD6 햲 SHJD6 햲 CJD6 햲 SCJD6 햲 65 65 100 100 65 100 200 200 35 35 65 65 35 65 200 200 25 25 35 35 25 35 100 100 JX J6 H6 H5 SJ S2 CJ SC STD STD 2060. 2060. 2480. 2820. 3000. 4950. STD STD 2060. 2060. 2480. 2820. 3000. 4950. STD STD 2060. 2060. 2480. 2820. 3000. 4950. 200, 200, 200, 200, 200, 200, 200, 200, 225, 225, 225, 225, 300, 300, 300, 300, 250, 250, 250, 250, 400 400 400 400 600 LXD6 햲 LD6 햲 HLXD6 햲 HLD6 햲 SLD6 햲 SHLD6 햲 CLD6 햲 SCLD6 65 65 100 100 65 100 200 200 35 35 65 65 35 65 150 150 25 25 35 35 25 35 100 100 LX L6 HL HO SL S6 CL C6 STD STD 2060. 2060. 2820. 4890. 4320. 5790. STD STD 2060. 2060. 2820. 4890. 4320. 5790. STD STD 2060. 2060. 2820. 4890. 4320. 5790. 450, 250, 250, 250, 300, 300, 300, 300, 500, 300, 300, 300, 400, 400, 400, 400, 600 350, 350, 350, 500, 500, 500, 500, Ampere Rating Breaker Type List Price Adder $ 240V AC 480V AC 600V AC Available Trip Values 80, 80, 80, 80, 80, 90, 90, 90, 90, 90, 100, 100, 100, 100, 100, 110, 110, 110, 110, 110, 300, 300, 300, 300, 125, 125, 125, 125, 125, 350, 350, 350, 350, 150, 150, 150, 150, 150, 200, 200, 200, 200, 200, 225, 225, 225, 225, 225, 250 250 250 250 250 400 400 400 400 400, 450, 500, 600 400, 450, 500, 600 400, 450, 500, 600 600 600 600 600 Vertically mounted 10 PANELBOARDS Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-35 Panelboards Type P3 Panelboards Selection Branch Circuit Breakers Max. Bolt-On Amp Breaker Rating Type BL BLH HBL BL, (HID) BLR (240V) 100 BLE (GFCI) BLEH (GFCI) BLF (GFCI) BLHF (GFCI) BGL��� BAF BAFH BQD NGB NEB HEB 125 ED4 ED6 HED4 HHED6 225 QJ2 QJH2 QJ2H HQJ2H List Price $ Amps 1-Pole 2-Pole 15–60 25. 45. 70 35. 85. 80–100 — 140. 15–60 35. 85. 70 75. 130. 80–100 — 200. 15–55 85. 270. 60–100 — 400. 15–30 45. 75. 15–60 — 110. 70–100 — 190. 15–30 220. 330. 40–60 — 330. 15–30 420. — 15–60 — 530. 15–30 140. 240. 40–60 — 250. 15–30 160. 280. 40–60 — 300. 15–30 — 100. 15–20 160. 330. 15–20 180. 340. 15–60 85. 270. 70–100 — 400. 15–60 130. 360. 70–100 210. 420. 110–125 — 710. 15–60 250. 370. 70–100 250. 490. 110–125 460. 890. 15–60 380. 560. 70–100 380. 690. 110–125 1160. 1280. 15–60 160. 440. 70–100 260. 520. 110–125 — 880. 15–60 — 460. 70–100 — 600. 110–125 — 1100. 15–60 490. 850. 70–100 490. 950. 110–125 — 1750. 15–60 — 860. 70–100 — 960. 110–125 — 1760. 60–225 — 420. 60–225 — 930. 60–225 — 1080. 60–225 — — 3-Pole 140. 190. 210. 220. 300. 310. 380. 490. — — — — — — — — — — — 130. — — 380. 490. 480. 540. 910. 560. 640. 1090. 710. 780. 1450. 590. 670. 1120. 700. 790. 1350. 950. 1070. 1970. 960. 1090. 1990. 880. 1140. 1410. 1940. Future $ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 170. 170. 170. 170. Provisions for Maximum Interrupting 120V AC 120/240V AC 10 — — 10 — — — 22 — 22 — — — 65 — — 10 — — — — — 10 — — 10 22 — — 22 10 — — 10 22 — — 22 10 — 10 — 22 — — 65 — — 100 100 100 100 100 100 85 85 85 85 85 85 100 100 100 100 100 100 65 — — — — — — — — — 100 — 100 — — — — — — — — — — — — — — — — — — — Rating (kA) 240V AC — — 10 — — 22 — 65 — 10 10 — — — — — — — — — — — — 65 100 100 100 85 85 85 100 100 100 — 65 65 65 65 — — — — 100 100 100 10 22 42 100 Subfeed Breakers PANELBOARDS 10 Breaker Type FD6 햳, FXD6 Provisions for Future $ 220.-- Ampere Ratings For Load 70 – 250 Maximum Interrupting Rating (kA) Symmetrical 240V AC 480V AC 600V AC 65 35 18 2440. 3010. 220.-- 70 – 250 100 65 25 JD6 햴, JXD6 Single 1720. 2180. 290.-- 200 – 400 65 35 25 HJD6 햴, HJXD6 Single 3160. 4220. 290.-- 200 – 400 100 65 35 Branch Device Limitations For panels applied on systems requiring neutral connections, some limitations BGL 2-pole is (1) phase and neutral 3-pole is (2) phases and neutral. NOTE:QJ Breakers are twin mounted in unit space and take 6" of unit space. Limited to (6) per panel max. BL, HBL, BLH and BQD breakers are mounted in common mountings in 3" or (6) pole increments. ED2, ED4, ED6, HED4 and HHED6 10-36 480V AC — — — — — — — — — — — — — — — — — — — — — — 14 14 25 25 25 35 35 35 65 65 65 — 18 18 25 25 — — — — 42 42 42 — — — — 600V AC — — — — — — — — — — — — — — — — — — — — — — — — — — — 22 22 22 25 25 25 — — — 18 18 — — — — — — — — — — — 250V DC — — — — — — — — — — — — — — — — — — — — — — 14 14 14 14 14 35 35 35 42 42 42 — 30 — 30 — — — — — 30 30 — — — — — Neutral Connectors Mounting Position When Used as Subfeed Breaker List Price $ Vertical 2-Pole 3-Pole Twin 1220. 1540. HFD6 햳,HFXD6 Twin 햲 277V AC — — — — — — — — — — — — — — — — — — — — — — — — 25 25 25 35 35 35 65 65 65 22 — — — — — — 65 65 42 42 — — — — — apply. By application rule (NEC 408.14), lighting and appliance panels are limited to 42 circuit installed. Each overcurrent Wire Range #14-#1/0 #14-3/0 #4 - 350 kcmil (1)#4 - 600 kcmil or (2)#6 - 250 kcmil Max. Number of Max. Connections Amps��� 44 12 6 125 200 250 1 400 device pole counts as a circuit. Additional limitations for these panels are based on available neutral connections. breakers are mounted in common mountings in 3" or (6) pole increments. Twin mounted subfeed breakers are mounted at bottom of panelboard only and adds 24" to the panel height. 햴 Subfeed breaker is mounted at bottom of panelboard only. 400 amp subfeed breaker adds 30" to the panel height. 햳 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P3 Panelboards Selection Typical Catalog Numbers Main Lugs Only – shown with aluminum bus, top fed, and surface trims 208Y/120V Maximum Panel Amp Rating 250 400 600 800 Maximum Panel Amp Rating 250 400 600 800 Unit Space (inches) 3-Phase, 4-Wire Catalog Number 27 33 39 45 51 21 27 33 39 45 21 27 33 39 45 21 27 33 39 45 P3C56ML250ATS P3C62ML250ATS P3C68ML250ATS P3C74ML250ATS P3C80ML250ATS P3C56ML400ATS P3C62ML400ATS P3C68ML400ATS P3C74ML400ATS P3C80ML400ATS P3C56ML600ATS P3C62ML600ATS P3C68ML600ATS P3C74ML600ATS P3C80ML600ATS P3C56ML800ATS P3C62ML800ATS P3C68ML800ATS P3C74ML800ATS P3C80ML800ATS Unit Space (inches) 240V 3-Phase, 3-Wire Catalog Number 27 33 39 45 51 21 27 33 39 45 21 27 33 39 45 21 27 33 39 45 P3D56ML250ATS P3D62ML250ATS P3D68ML250ATS P3D74ML250ATS P3D80ML250ATS P3D56ML400ATS P3D62ML400ATS P3D68ML400ATS P3D74ML400ATS P3D80ML400ATS P3D56ML600ATS P3D62ML600ATS P3D68ML600ATS P3D74ML600ATS P3D80ML600ATS P3D56ML800ATS P3D62ML800ATS P3D68ML800ATS P3D74ML800ATS P3D80ML800ATS 240/120V List Price $ 1760.00 1980.00 2220.00 2440.00 2660.00 2120.00 2350.00 2580.00 2800.00 3020.00 2410.00 2630.00 2850.00 3080.00 3310.00 2850.00 3080.00 3310.00 3530.00 3760.00 List Price $ 1660.00 1890.00 2110.00 2330.00 2570.00 2050.00 2270.00 2490.00 2720.00 2950.00 2290.00 2510.00 2730.00 2970.00 3190.00 2730.00 2970.00 3190.00 3410.00 3640.00 3-Phase, 4-Wire Catalog Number P3B56ML250ATS P3B62ML250ATS P3B68ML250ATS P3B74ML250ATS P3B80ML250ATS P3B56ML400ATS P3B62ML400ATS P3B68ML400ATS P3B74ML400ATS P3B80ML400ATS P3B56ML600ATS P3B62ML600ATS P3B68ML600ATS P3B74ML600ATS P3B80ML600ATS P3B56ML800ATS P3B62ML800ATS P3B68ML800ATS P3B74ML800ATS P3B80ML800ATS 408Y/277V 3-Phase, 4-Wire Catalog Number P3E56ML250ATS P3E62ML250ATS P3E68ML250ATS P3E74ML250ATS P3E80ML250ATS P3E56ML400ATS P3E62ML400ATS P3E68ML400ATS P3E74ML400ATS P3E80ML400ATS P3E56ML600ATS P3E62ML600ATS P3E68ML600ATS P3E74ML600ATS P3E80ML600ATS P3E56ML800ATS P3E62ML800ATS P3E68ML800ATS P3E74ML800ATS P3E80ML800ATS List Price $ 1760.00 1980.00 2220.00 2440.00 2660.00 2120.00 2350.00 2580.00 2800.00 3020.00 2410.00 2630.00 2850.00 3080.00 3310.00 2850.00 3080.00 3310.00 3530.00 3760.00 120/240V or 250V DC Max. 1-Phase, 3-Wire Catalog Number P3A56ML250ATS P3A62ML250ATS P3A68ML250ATS P3A74ML250ATS P3A80ML250ATS P3A56ML400ATS P3A62ML400ATS P3A68ML400ATS P3A74ML400ATS P3A80ML400ATS P3A56ML600ATS P3A62ML600ATS P3A68ML600ATS P3A74ML600ATS P3A80ML600ATS P3A56ML800ATS P3A62ML800ATS P3A68ML800ATS P3A74ML800ATS P3A80ML800ATS List Price $ 1660.00 1890.00 2110.00 2330.00 2570.00 2050.00 2270.00 2490.00 2720.00 2950.00 2290.00 2510.00 2730.00 2970.00 3190.00 2730.00 2970.00 3190.00 3410.00 3640.00 List Price $ 480V��� 3-Phase, 3-Wire Catalog Number List Price $ 1970.00 2200.00 2430.00 2650.00 2880.00 2120.00 2350.00 2580.00 2800.00 3020.00 2410.00 2630.00 2850.00 3080.00 3310.00 2850.00 3080.00 3310.00 3530.00 3760.00 P3F56ML250ATS P3F62ML250ATS P3F68ML250ATS P3F74ML250ATS P3F80ML250ATS P3F56ML400ATS P3F62ML400ATS P3F68ML400ATS P3F74ML400ATS P3F80ML400ATS P3F56ML600ATS P3F62ML600ATS P3F68ML600ATS P3F74ML600ATS P3F80ML600ATS P3F56ML800ATS P3F62ML800ATS P3F68ML800ATS P3F74ML800ATS P3F80ML800ATS 1660.00 1890.00 2110.00 2330.00 2570.00 2050.00 2270.00 2490.00 2720.00 2950.00 2290.00 2510.00 2730.00 2970.00 3190.00 2730.00 2970.00 3190.00 3410.00 3640.00 10 PANELBOARDS 햲 For 600V, change “F” in position 3 to “G.” Price only branch breakers with 600V ratings. Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-37 Panelboards Type P3 Panelboards Selection Typical Catalog Numbers Main Circuit Breaker – shown with aluminum bus, top fed, and surface trims Maximum Panel Amp Rating 250 400 600 Maximum Panel Amp Rating 250 400 600 List Price $ 240/120V 3-Phase, 4-Wire Catalog Number 21 27 33 39 45 9 15 21 27 33 9 15 21 27 33 P3C56FD250ATS P3C62FD250ATS P3C68FD250ATS P3C74FD250ATS P3C80FD250ATS P3C56JD400ATS P3C62JD400ATS P3C68JD400ATS P3C74JD400ATS P3C80JD400ATS P3C56LD600ATS P3C62LD600ATS P3C68LD600ATS P3C74LD600ATS P3C80LD600ATS 3430.00 3660.00 3880.00 4110.00 4340.00 3830.00 4050.00 5190.00 5420.00 5650.00 6660.00 6890.00 7120.00 7340.00 7570.00 P3B56FD250ATS P3B62FD250ATS P3B68FD250ATS P3B74FD250ATS P3B80FD250ATS P3B56JD400ATS P3B62JD400ATS P3B68JD400ATS P3B74JD400ATS P3B80JD400ATS P3B56LD600ATS P3B62LD600ATS P3B68LD600ATS P3B74LD600ATS P3B80LD600ATS Unit Space (inches) 240V 3-Phase, 3-Wire Catalog Number List Price $ 408Y/277V 3-Phase, 4-Wire Catalog Number 21 27 33 39 45 9 15 21 27 33 9 15 21 27 33 P3D56FD250ATS P3D62FD250ATS P3D68FD250ATS P3D74FD250ATS P3D80FD250ATS P3D56JD400ATS P3D62JD400ATS P3D68JD400ATS P3D74JD400ATS P3D80JD400ATS P3D56LD600ATS P3D62LD600ATS P3D68LD600ATS P3D74LD600ATS P3D80LD600ATS 3340.00 3570.00 3790.00 4020.00 4240.00 4090.00 3850.00 4090.00 4310.00 4540.00 6260.00 6500.00 6720.00 6950.00 7180.00 P3E56FD250ATS P3E62FD250ATS P3E68FD250ATS P3E74FD250ATS P3E80FD250ATS P3E56JD400ATS P3E62JD400ATS P3E68JD400ATS P3E74JD400ATS P3E80JD400ATS P3E56LD600ATS P3E62LD600ATS P3E68LD600ATS P3E74LD600ATS P3E80LD600ATS List Price $ 3430.00 3660.00 3880.00 4110.00 4340.00 3830.00 4050.00 5190.00 5420.00 5650.00 6660.00 6890.00 7120.00 7340.00 7570.00 List Price $ 3450.00 3670.00 3890.00 4120.00 4350.00 5190.00 4940.00 5190.00 5420.00 5650.00 6660.00 6890.00 7120.00 7340.00 7570.00 120/240V or 250V DC Max 1-Phase, 3-Wire Catalog Number List Price $ P3A56FD250ATS P3A62FD250ATS P3A68FD250ATS P3A74FD250ATS P3A80FD250ATS P3A56JD400ATS P3A62JD400ATS P3A68JD400ATS P3A74JD400ATS P3A80JD400ATS P3A56LD600ATS P3A62LD600ATS P3A68LD600ATS P3A74LD600ATS P3A80LD600ATS 3540.00 3770.00 4000.00 4220.00 4450.00 3260.00 4720.00 4940.00 5180.00 5410.00 6260.00 6500.00 6720.00 6950.00 7180.00 480V ��� 3-Phase, 3-Wire Catalog Number List Price $ P3F56FD250ATS P3F62FD250ATS P3F68FD250ATS P3F74FD250ATS P3F80FD250ATS P3F56JD400ATS P3F62JD400ATS P3F68JD400ATS P3F74JD400ATS P3F80JD400ATS P3F56LD600ATS P3F62LD600ATS P3F68LD600ATS P3F74LD600ATS P3F80LD600ATS 3540.00 3770.00 4000.00 4220.00 4450.00 3260.00 4720.00 4940.00 5180.00 5410.00 6260.00 6500.00 6720.00 6950.00 7180.00 For 600V, change “F” in position 3 to “G.” Price only branch breakers with 600V ratings. PANELBOARDS 10 햲 Unit Space (inches) 208Y/120V 3-Phase, 4-Wire Catalog Number 10-38 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P3 Panelboard Modifications and Additions Selection Subfeed, Feed-Thru and Split Bus Enclosures Ampere Rating Extra Gutter to Sides or Ends of the Can List Price $ Description 6" end gutter . . . . . . . . . . . . . . . . . . . . . 2" side gutter . . . . . . . . . . . . . . . . . . . . . Barrier in gutter (add to extra gutter price) . . . . . . . . . . . . . . . . . . . . Hinged trims . . . . . . . . . . . . . . . . . . . . . Piano hinged trims . . . . . . . . . . . . . . . . Door-in-door trims . . . . . . . . . . . . . . . . Screw to the box trims . . . . . . . . . . . . . 235. 200. 200. 160. 360. 360. 160. Trim mounted devices . . . . . . . See page 10–72 • Pilot lights • Toggle switches • Push buttons (Devices mounted and wired to the trim should also have hinged trim specified) Painted boxes . . . . . . . . . . . . See page 10–72 Custom colors . . . . . . . . . . . See painted boxes Increase gauge trims and boxes . . . . . . . . . . . . . See page 10–72 Stainless steel trims and boxes, Type 1 . . . . . . See page 10–72 Aluminum trims and boxes, Type 1 . . . . . . See page 10–72 Meters (Contact sales for pricing and application engineering for space requirements) Panel Skirts See page 10-73 Special Locks TEY . . . . . . . . . . . . . . . . . . . . . . . . . . . TEU1 . . . . . . . . . . . . . . . . . . . . . . . . . . Cat 60 . . . . . . . . . . . . . . . . . . . . . . . . . LL803 . . . . . . . . . . . . . . . . . . . . . . . . . LL806 . . . . . . . . . . . . . . . . . . . . . . . . . Yale 47 (NYC) . . . . . . . . . . . . . . . . . . . 235. 255. 235. 235. 235. 425. Panel Bus Modifications Amperes Rating Main Bus Catalog Number 125A 250A 400A 600A 750 A/SI AL. Copper (tin pltd.) B F 190. 340. 190. 340. 340. 645. 910. 1335. 475. 1220. Copper (silver pltd.) E 455. 455. 1000 A/SI Copper (tin pltd.) G 730. 730. 1020. 2110. 1000 A/SI Copper (silver pltd.) H 1070. 1070. 1240. 2355. List Price $ 3-Pole 2-Pole Connector Cu/Al Wire Range Subfeed (Double) Lugs for Main Lug Panelboards Only 225/250 400 85. 85. 235. 235. (2)—#6 AWG-350 kcmil (2)—250 kcmil (1)—600 kcmil Feed-Thru Lugs — Cannot Be Used in Conjunction with TVSS or Subfeed Breakers See page 10-40 for unit space adders and compatibility with other options. 225/250 190. 160. (1)—#6 AWG-350 kcmil 400 490. 445. (2)—250 kcmil (1)—600 kcmil 600 720. 680. (2)—250-500 kcmil 800 770. — (2)—600 kcmil (1)—#6 AWG-350 kcmil Split Bus 225/250 245. 180. 400 490. 445. (2)—250 kcmil (1)—600 kcmil (2)—250-500 kcmil 600 720. 680. 800 1435. 1390. (2)—600 kcmil Bus mounted TVSS . . . . . . . . . . . . See Section 9 for TPS1 Service Entrance Label Type P3 Panelboards are factory labeled suitable for use as service entrance equipment when NEC requirements are met. A panelboard cannot have more than six main disconnects, unless it is a lighting and appliance branch panelboard. Lighting and appliance branch panelboards are limited to two main disconnects. Grounding of Panelboards Ground Bars except for brazed to box are shipped with the panel interior factory mounted. • Non-Insulated Equipment Ground Bar – STD • Copper Non-Insulated Ground Bar. . . . . . 40. • Al Insulated Equipment Ground Bar . . . . 40. • Cu Insulated Equipment Ground Bar . . . . 75. • Ground Bar Brazed to Box . . . . . . . . . . . 245. (recommended for painted boxes) Shunt Trip on Main or Branch See breaker section for list price adders. BL, BLH, HBL, BQD, ED4, HED4, ED6, HED6, HHED6, QJ2, QJ2H, QJH2, HQJ2H as branch only. BL, BLH, HBL, ED2, ED4, HED4, ED6, HED6, HHED6 uses 1" unit space for shunt trip. All others may be used on mains or subfeeds. Branch and Main Breaker Accessories See page 10-70 and Breaker Section • Handle blocks • Handle locks • Aux. Contacts햲 • UVR햲 Increase capacity neutral up to 200% Main Bus Amps List Price Adder $ 125 250 400 600 340. 530. 560. 625. See page 10-40 for unit space adders and compatibility with other options. Copper MLO Only Main Bus Amps List Price Adder $ 125 250 400 600 115. 190. 285. 285. QJ2, QJ2-H, QJH2, HQJ2H, ED4, ED6, HED4, HED6, HHED6, FXD6, HFD6, JXD6, JD6, HJD6, HJXD6 Time Clocks Time clocks may be mounted in a 23" enclosure to be cable connected to the panel. Sangamo, Tork or Paragon time clock can be supplied and mounted in panelboard cabinet. Adds 12" to panel height. Mounts in Sub-area. Description Time Clock (1 or 2-pole, single or double throw contacts; 3-pole, single throw) 277V maximum with plain dial Options— Astronomical dial An omitting device Reserve power or carryover Space and mounting provisions only List Price $ 1070. 210. 75. 2450. 540. 10 PANELBOARDS 햲 Accessories on 1" pole breakers (BL, BQD, ED) will take unit space. Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-39 Panelboards Type P3 Panelboard Standard Modifications Selection Option Combinations Amps Incoming Subfeed Lugs Main Lug Only — Main Lugs w/Subfeed Lugs • Main Breaker (Horiz. FD) — Main Breaker (Vert. FD) None Std. Main Breaker (CFD) None Std. Main Lug Only • — — — — Main Breaker (JD) None Std. Main Breaker (CJD) None Std Main Lug Only — Main Breaker LD — Main Breaker CLD — Main Lug Only — 250 400햳햴 600햳햴 FD햲 Subfeed JD햲 Subfeed FD햳 Subfeeds 200% Neutral Min. Box Size (in.) • — — • — — • — • • — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — • — — • — — • — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — — — — — — — — — — — — — — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — — • — — • — — — — — — — — — • — — — — • — — — — • — — — — • — — — — • — — — — • — — — — • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • — • • • • — • • • • — • • • • — • 56 56 56 56 56 62 56 56 56 56 68 56 56 56 56 62 56 62 68 68 74 62 74 74 74 80 56 56 56 56 62 56 62 68 68 74 62 68 74 74 80 56 56 56 56 62 PANELBOARDS 10 800햳햴 Feed-thru Lugs 햲 햳 햴 Subfed lugs are currently not offered as standard with main circuit breakers. Subfed lugs on panels above 400A are not standard. 200% neutral cannot be provided along with a 400A subfeed breaker because the breaker blocks the 4th lug site. 10-40 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Unit Space (in.) 27 15 9 21 21 9 21 9 15 9 9 21 15 9 9 9 9 9 9 9 9 9 9 9 9 9 21 15 9 9 9 9 9 9 9 9 9 9 9 9 9 21 9 9 9 9 Panelboards Type P3 Panelboard Connector Modifications Selection Compression Lugs List Price $ 3-Phase/ 3-Phase/ 1-Phase/ 1-Phase/ 4-Wire 3-Wire 3-Wire 2-Wire Style Amp Rating Breaker Type Compression Connectors Box Height Addition MLO 250 400 N/A N/A 75. 115. 75. 115. 65. 95. N/A N/A FXD6, HFD6, CFD6 200. 265. 225. 150. 200. 180. 150. 200. 180. 115. 200. 180. 400 JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, SCJD6 LD6, LXD6, HLD6, CJD6, SLD6, SHLD6, SCLD6 (2)#1/0 AWG - 500 kcmil Cu or Al — — — — — CFD6 requires an additional 6.0" box height 6 105. 150. 600 800 250 (1)#6 AWG - 350 kcmil (1) 250 - 500 kcmil or (2)# 1/0 AWG - 250 kcmil (2)#3/0 AWG - 500 kcmil (2) 400-750 kcmil Cu only (1)#6 AWG - 350 kcmil Cu or Al 305. 235. 235. 235. (2)#2/0 AWG - 500 kcmil Cu or Al 6 305. 235. 235. 235. Main Breaker 600 Alternate Lugs Style Amp Rating Breaker Type Compression Connectors Box Height Addition List Price $ MLO 400 N/A 6 275. Main Breaker 800 400 N/A JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, SCJD6 (1) 250 - 750 kcmil or (2)#3/0 AWG - 250 kcmil Cu or Al (2) 600 kcmil (1)#4/0 AWG - 750 kcmil Cu or Al 6 6 390. 305. Enclosure Modifications List Price Adder $ Panel Width 24" Description NEMA 3R enclosure s NEMA 3R/12 enclosure s Gasket between trim and box (Type 1) 1175. 1175. 890. NEMA-4 For Type P3 Water Tight, Dust Tight, Steel Enclosure (consult plant for actual enclosure size) Box Height Inches 56 62 68 74 80 Enclosure Size H W 56 24 62 24 68 24 74 24 80 24 D 7.75 7.75 7.75 7.75 7.75 List Price $ 16260. 20545. 24835. 29340. 29350. NEMA-4X For Type P3 Water Tight, Dust Tight and Corrosion Resistant (consult plant for actual enclosure size) Box Height Inches 56 62 68 74 80 Enclosure - Stainless Steel and Steel with Epoxy Coating H W D 56 24 7.75 62 24 7.75 68 24 7.75 74 24 7.75 80 24 7.75 Enclosure - Fiberglass Size (inches) H W D 60 36 12 66 36 8 72 36 8 78 36 8 84 36 8 List Price $ 20265. 23710. 27435. 31155. 31610. Remote Switch Modifications (see page 10-71) Application For Remote Switch Switch Type 920 911 10 LEN Modification Adds 12" to unit space ≤ 225A Adds 21" unit space >225 ≤400 Amps Add 10" to width and 8" DP minimum and 24" to height 30A Adds 15" to unit space >30A ≤ 100 Adds 12" to unit space 100 A ≤ 200 Adds 12" to unit space and 10" Dp. min. PANELBOARDS Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-41 Panelboards Type P3 Panelboard Kits and Accessories Selection Standard Enclosures Catalog Number Box Height (in.) 56 Type 1 Standard Trim Box 24WD56 Surface P3S56 Flush P3F56 Type 3R 24NRD56 Type 3R/12 24WPD56 62 24WD62 P3S62 P3F62 24NRD62 24WPD62 68 24WD68 P3S68 P3F68 24NRD68 24WPD68 74 24WD74 P3S74 P3F74 24NRD74 24WPD74 80 24WD80 P3S80 P3F80 24NRD80 24WPD80 Options For Type 1 Trims Items must be ordered as manual line item on factory Hinged trim – Add “H” suffix Door-in-door – Add “D” suffix Metal card holder – Add “M” suffix Breaker Kits and Accessories Kit Number BBKB32 BBKNB32 BBKEB32 BBKED32 BBKQ2 Contents Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware Kit contains breaker support, inter-phase barriers, (3) A/C connectors, (1) B connector, hardware Kit contains all connectors and cover plates necessary to mount both 2 and 3-pole breakers 3" empty space filler and hardware 6" empty space filler and hardware Bonding strap and hardware List Price $ 85.00 90.00 113.00 90.00 350.00 45.00 51.00 23.00 PANELBOARDS 10 DFFP3 DFFP6 P3BK1 Description BL/BQD 6-pole 3" branch breaker kit NGB 6-pole 3" branch breaker kit NEB/HEB 6-pole 3" branch breaker kit ED 6-pole 3" branch breaker kit Branch breaker kit for 2 and 3-pole QJ twin mount Deadfront filler 3" Deadfront filler 6" P3 bonding kit 10-42 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P3 Panelboards Dimensions Type 1 Box Box is symmetrical Box To Wall Mounting Holes 2 in. [ 51 ] .31 in. [8] 7.625 in. [ 199 ] Mounting Dimple Interior To Box Mounting Stubs 햲 56 in. 62 in. 68 in. [ 1422 ] [ 1575 ] [ 1727 ] 74 in. 80 in. [ 1880 ] [ 2032 ] 7.625 in. [ 199 ] 12.63 in. [ 321 ] 15 in. [ 381 ] 7.75 in. [ 197 ] 2 in. [ 51 ] 햲 24 in. [610] 햲 Type 3R and 3R/12 Box 9.5 in. [ 241 ] .50 in. [ 13 ] 2 in. [ 51 ] Mounting Bracket 56 in. 62 in. 68 in. 햲 [ 1422 ] [ 1575 ] [ 1727 ] 74 in. 80 in. [ 1880 ] [ 2032 ] 2 in. [ 51 ] 2 in. [ 51 ] 1 in. [25] 25.5 in. [ 648 ] 햲 햲 Dimensions are interior of the box. Add 5/8" to width for absolute dimension. Add 1/8" to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-43 PANELBOARDS 27.5 in. [ 699 ] 7.75 in. [ 146 ] 10 24 in. 햲 [ 610 ] Panelboards Type P4 Panelboards Features The P4 panel is a medium sized footprint distribution panel to fit a large number of applications that require more or larger branch devices and higher amp ratings than the lighting panel class offer. Even with the increased capacity, this panel is a space saver with its 32" width and 10" depth. The P4 panel offers a wide array of factory-assembled options and has the ability to mix breaker frames in unit space up to 800 amps and fusible switches up to 200 amps. Bussing options for the P4 vary from the standard temperature rated aluminum to temperature rated copper and 750A/Si aluminum and 1000A/Si copper designs. All aluminum bussing in the P4 panel is tin-plated as a standard. Silver-plated is offered as the default for copper bus and tin as an option. Integrated time clocks, bus mounted contactors as mains or submains, split bus and subfeed lugs (up to 600 amp) are just a few of the options of this flexible panel. The 4 panel configurations defined by the unit space allowed for a given amperage, main device and box height. The P4 panel starts with a 60" high box. All of the branch devices are unit space mounted. Breakers and switches can be mixed and matched to meet customer requirements. General Main Lug / Main Breaker / Main Switch Enclosure – Standard Type 1 enclosure is 32" wide x 10" deep. X Box Height is determined by main device and unit space. See charts for box height. Voltage – 600V AC max. 250V DC max. Amperage – 400-800 amp main breaker (check with factory on availability of 800 amp), 400-1200 amp MLO, 100-200 amp main switch. Short Circuit Rating – 200 KAIC max. symmetrical or equal to the lowest rated device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to a three-cycle rating. The three-cycle rating for the P4 panel is limited to 42 KAIC. Note that the main device may be mounted remote from the panel. Bussing – The P4 panel has more options to meet market requirements. The standard bussing is temperature rated aluminum. The rating is per the requirements of UL 67 – the standard for panelboards. All aluminum bussing is tin-plated. Optional bussing for the P4 panel is: 750 A/Si aluminum, temperature rated copper, and 1000 A/Si copper. The copper bus option for this panel is silver-plated. Enclosure Selection 햲 Enclosure Dimension in Inches (mm) Available Circuit Space in Inches (mm) Dimension “C” H Main Lug Main Breaker 400 / 800A 400 / 800A 100 / 200A 30 (762) 45 (1143) 60 (1524) 21.25 (540) 36.25 (921) 51.25 (1302) 20 (508) 35 (889) 50 (1270) W D Type 1, 3R/12 60 (1524) 75 (1905) 90 (2286) 32 (813) 32 (813) 32 (813) 10 (254) 10 (254) 10 (254) Main Switch Main Breaker Unit Space Dimensions PANELBOARDS 10 Dimensions in Inches (mm) Ampere Rating Breaker Type A 400 400–600 800 JXD6, JD6, HJD6 LXD6, LD6, HLD6, SJD6, SHJD6, SLD6, SHLD6 LMD6, LMXD6 10.42 (265) 10.42 (265) 10.00 (265) Neutral B 13.125 (333) Main Switch Connectors Ampere Rating 100 200 햲 Connectors suitable for Copper or Aluminum (1) #10-#1/0 AWG (Cu or Al) (1) #6 AWG-300 kcmil Standard trim is four piece without door. Surface or flush one piece trim is available for 32 in. (813 mm) wide circuit breaker panel. 10-44 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Weight – Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is about 8 lbs. (1 kg) per inch (54g per mm) of box height. Main Lugs ��� Ampere Rating 400 (1) - #3/0 AWG-500 kcmil (2) - #3/0 AWG-250 kcmil (2) - #3/0 AWG-500 kcmil (3) - #3/0 AWG-500 kcmil (4) - #3/0 AWG-500 kcmil (4) - #3/0 AWG-500 kcmil 600 800 1000 1200 햲 Connectors Suitable for Copper or Aluminum Alternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens. Gauge Steel of Boxes Fronts, Surface and Flush Dimensions in inches (mm) Gauge Steel Width Height Box Fronts 32" (813) 60 - 75 - 90 (1524, 1905, 2286) #16��� #14 (1 piece trim) 14 Ga (4 piece trim) 햲 Box has 16 gauge side panels and 12 gauge back support. Panelboards Type P4 Panelboards Dimensions Main Lugs Only Wire Bending Space Lugs Standard Oversize Crimp Standard w/Subfeed Standard w/Feed-thru Dimensions in inches (mm) Main Lug 400A 600A 800A A B C 16.500 (419) 16.500 (419) 19.187 (487) 16.750 (425) 16.500 (419) 16.750 (419) 21.750 (552) 18.250 (464) 15.969 (406) 16.750 (419) 1000A D 1200A E 15.969 (406) 25.969 (660) 18.687 (475) — 15.969 (406) 25.969 (660) 18.250 (464) — 15.969 (406) 25.969 (660) 18.250 (464) — — — — Neutral 400-600A F 800-1200A G 13.125 (333) 18.125 (460) 15.937 (405) 13.125 (333) 13.125 (333) 13.125 (333) 23.125 (587) 15.937 (405) 13.125 (333) 13.125 (333) Main Lugs Only Unit Space Branch Switch Unit Space Mounting Height in inches (mm) Ampere Rating Number of Poles Twin Mounted 30-30 30-30 30-60 60-60 60-100 100-100 200-200 200 200 30-30 30-60 60-60 60-100 100-100 200-200 100 200 2, 2, 2, 2, 2, 2, 3 2 3 2, 2, 2, 2, 2, 3 2, 2, 2.50 (64) 5.00 (127) 5.00 (127) 5.00 (127) 7.50 (191) 7.50 (191) 10.00 (254) — — 7.5 (191) 7.5 (191) 7.5 (191) 7.5 (191) 7.5 (191) 10.00 (254) — — 3 3 3 3 3 3 3 3 3 3 3 3 3 Single Mounted — — — — — — — 7.50 10.00 — — — — — — 7.50 10.00 (191) (254) (191) (254) AC Voltage Cables Per Connector Connectors Suitable for Copper or Aluminum 240 240 240 240 240 240 240 240 240 600 600 600 600 600 600 600 600 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 #14 - #8 AWG (Cu Only) #14 - #4 AWG #14 - #4 AWG #14 - #4 AWG #10 - #1/0 AWG #10 - #1/0 AWG #6 AWG - 350 kcmil #6 AWG - 350 kcmil #6 AWG - 350 kcmil #14 - #8 AWG #14 - #4 AWG #14 - #4 AWG #10-#1/0 AWG #10-#1/0 AWG #6 AWG - 250 kcmil #10-#1/0 AWG #6 AWG - 250 kcmil 10 PANELBOARDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-45 Panelboards Type P4 Panelboards Dimensions Branch Breaker Side Gutter Inches (mm) Reference Letter Panel Width 32 in. Inches (mm) A 11.000 7.000 6.500 5.250 4.615 8.769 12.500 8.250 10.000 7.000 5.000 7.500 10.000 10.500 7.750 (279) (178) (146) (133) (177) (223) (265) (210) (254) (178) (127) (191) (254) (267) (197) B C D F G H I J K L M N N O P PANELBOARDS 10 A B C D F G H I J K L M N O P BL, BLH, HBL, BQD, BLE BL, BLH, HBL, BQD, BLE BLEH, BLR, BLF, BLHF BLEH, BLR, BLF, BLHF BAF, BAHF, BGL BAF, BAHF, BGL ED4, ED6 ED4, ED6 HED4, HHED6 HED4, HHED6 QJ2, QJH2 QJ2, QJH2 QJ2H, HQJ2H QJ2H, HQJ2H FXD6, FD6 FXD6, FD6 HFD6 HFD6 CED6 CED6 CFD6 JXD6, JD6, LXD6, LD6, SLD6 SJD6, SHJD6, HLD6, SHLD6 CJD6, SCJD6, CLD6, SCLD6 30–60A 5" switch 30–60A 5" switch 30–60A 7.5" switch 30–60A 7.5" switch 100–200A switch 100–200A switch 100–200A switch LMD6, LMXD6, HLMD6, HLMXD6 NMG, HMG, LMG NGB NGB NEB, HEB NEB, HEB 10-46 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog A B C D F G H I J K L M N N O P Panelboards Power and Distribution Selection Type P4 Shown with Standard Mains, Top Fed Panels are top feed, surface mounted. and Surface Trim For bottom feed, change “T” in position 12 to “B”. For flush mounting, Catalog number is for aluminum main change “S” in position 13 to “F”. bus. For optional copper main bus change “A” in position 11 to “C”. Main Lugs Only — shown with aluminum bus, top fed, and surface trims. Maximum Panel Amps 400 600 800 1000 1200 Maximum Panel Amps 400 600 800 1000 1200 Unit Space (inches) 30 45 60 30 45 60 30 45 60 30 45 60 30 45 60 208Y/120V Unit Space (inches) 30 45 60 30 45 60 30 45 60 30 45 60 30 45 60 240V Replace fifth and sixth position in panelboard catalog number, with alternate main breaker code. Use price adders from main breaker section table. Horizontally mounted. 240/120V 3-Phase, 4-Wire Catalog Number P4C60ML400ATS P4C75ML400ATS P4C90ML400ATS P4C60ML600ATS P4C75ML600ATS P4C90ML600ATS P4C60ML800ATS P4C75ML800ATS P4C90ML800ATS P4C60ML101ATS P4C75ML101ATS P4C90ML101ATS P4C60ML120ATS P4C75ML120ATS P4C90ML120ATS List Price $ 1220.00 1270.00 1360.00 1570.00 1660.00 1750.00 1910.00 2020.00 2120.00 2230.00 2350.00 2460.00 2510.00 2650.00 2800.00 3-Phase, 4-Wire Catalog Number P4B60ML400ATS P4B75ML400ATS P4B90ML400ATS P4B60ML600ATS P4B75ML600ATS P4B90ML600ATS P4B60ML800ATS P4B75ML800ATS P4B90ML800ATS P4B60ML101ATS P4B75ML101ATS P4B90ML101ATS P4B60ML120ATS P4B75ML120ATS P4B90ML120ATS 120/240V or 250 Vdc Max List Price $ 1220.00 1270.00 1360.00 1570.00 1660.00 1750.00 1910.00 2020.00 2120.00 2230.00 2350.00 2460.00 2510.00 2650.00 2800.00 List Price $ 1010.00 1060.00 1110.00 1270.00 1360.00 1410.00 1510.00 1590.00 1690.00 1760.00 1870.00 1960.00 2020.00 2130.00 2260.00 3-Phase, 4-Wire Catalog Number P4E60ML400ATS P4E75ML400ATS P4E90ML400ATS P4E60ML600ATS P4E75ML600ATS P4E90ML600ATS P4E60ML800ATS P4E75ML800ATS P4E90ML800ATS P4E60ML101ATS P4E75ML101ATS P4E90ML101ATS P4E60ML120ATS P4E75ML120ATS P4E90ML120ATS List Price $ 1220.00 1270.00 1360.00 1570.00 1660.00 1750.00 1910.00 2020.00 2120.00 2230.00 2350.00 2460.00 2510.00 2650.00 2800.00 480V 햲 480Y/277V 3-Phase, 3-Wire Catalog Number P4D60ML400ATS P4D75ML400ATS P4D90ML400ATS P4D60ML600ATS P4D75ML600ATS P4D90ML600ATS P4D60ML800ATS P4D75ML800ATS P4D90ML800ATS P4D60ML101ATS P4D75ML101ATS P4D90ML101ATS P4D60ML120ATS P4D75ML120ATS P4D90ML120ATS 1-Phase, 3-Wire Catalog Number P4A60ML400ATS P4A75ML400ATS P4A90ML400ATS P4A60ML600ATS P4A75ML600ATS P4A90ML600ATS P4A60ML800ATS P4A75ML800ATS P4A90ML800ATS P4A60ML101ATS P4A75ML101ATS P4A90ML101ATS P4A60ML120ATS P4A75ML120ATS P4A90ML120ATS List Price $ 1200.00 1270.00 1360.00 1570.00 1660.00 1750.00 1910.00 2020.00 2120.00 2230.00 2350.00 2460.00 2510.00 2650.00 2800.00 3-Phase, 3-Wire Catalog Number P4F60ML400ATS P4F75ML400ATS P4F90ML400ATS P4F60ML600ATS P4F75ML600ATS P4F90ML600ATS P4F60ML800ATS P4F75ML800ATS P4F90ML800ATS P4F60ML101ATS P4F75ML101ATS P4F90ML101ATS P4F60ML120ATS P4F75ML120ATS P4F90ML120ATS List Price $ 1010.00 1060.00 1110.00 1270.00 1360.00 1410.00 1510.00 1590.00 1690.00 1760.00 1870.00 1960.00 2020.00 2130.00 2260.00 Main Circuit Breaker — shown with standard mains, aluminum bus, top fed, and surface trims. Maximum Panel Amps 400 600 800 400 800 List Price $ 4000.00 4210.00 4420.00 6250.00 6600.00 6950.00 8020.00 8480.00 8930.00 240V 3-Phase, 4-Wire Catalog Number P4B60JX400ATS P4B75JX400ATS P4B90JX400ATS P4B60LX600ATS P4B75LX600ATS P4B90LX600ATS P4B60M1800ATS P4B75M1800ATS P4B90M1800ATS 120/240V or 250 Vdc Max List Price $ 4000.00 4210.00 4420.00 6250.00 6600.00 6950.00 8020.00 8480.00 8930.00 List Price $ 3820.00 4010.00 4220.00 6000.00 6310.00 6650.00 8020.00 8480.00 8930.00 3-Phase, 4-Wire Catalog Number P4E60JX400ATS P4E75JX400ATS P4E90JX400ATS P4E60LX600ATS P4E75LX600ATS P4E90LX600ATS P4E60M1800ATS P4E75M1800ATS P4E90M1800ATS 1-Phase, 3-Wire Catalog Number P4A60JX400ATS P4A75JX400ATS P4A90JX400ATS P4A60LX600ATS P4A75LX600ATS P4A90LX600ATS P4A60M1800ATS P4A75M1800ATS P4A90M1800ATS List Price $ 3450.00 3630.00 3820.00 5250.00 5550.00 5840.00 6710.00 7160.00 7610.00 480V 햲 480Y/277V 3-Phase, 3-Wire Catalog Number P4D60JX400ATS P4D75JX400ATS P4D90JX400ATS P4D60LX600ATS P4D75LX600ATS P4D90LX600ATS P4D60M1800ATS P4D75M1800ATS P4D90M1800ATS Note: For 600V application, change “F” in position 3 to “G”. See alternate main breaker table on page 10-48 for 600V rated mains. Change position 5 and 6 and add Discount Schedule PBSB 240/120V 3-Phase, 4-Wire Catalog Number P4C60JX400ATS P4C75JX400ATS P4C90JX400ATS P4C60LX600ATS P4C75LX600ATS P4C90LX600ATS P4C60M1800ATS P4C75M1800ATS P4C90M1800ATS List Price $ 4120.00 4340.00 4560.00 6250.00 6600.00 6950.00 8020.00 8480.00 8930.00 3-Phase, 3-Wire Catalog Number P4F60JX400ATS P4F75JX400ATS P4F90JX400ATS P4F60LX600ATS P4F75LX600ATS P4F90LX600ATS P4F60M1800ATS P4F75M1800ATS P4F90M1800ATS List Price $ 3940.00 4140.00 4350.00 6000.00 6310.00 6650.00 8020.00 8480.00 8930.00 price from table. Price only 600V rated branch breakers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-47 PANELBOARDS 600 Unit Space (inches) 21.25 36.25 51.25 21.25 36.25 51.25 21.25 36.25 51.25 208Y/120V 10 Maximum Panel Amps Unit Space (inches) 21.25 36.25 51.25 21.25 36.25 51.25 21.25 36.25 51.25 Panelboards Power and Distribution Selection Main Fusible Switch (fuses not included) Maximum Panel Ampere Rating 200 Maximum Panel Ampere Rating 200 Unit Space (inches) 20 35 20 35 Unit Space (inches) 20 35 20 35 208Y/120V 240/120V 120/240V 3-Phase, 4-Wire Catalog Number P4C60MS100ATS P4C75MS100ATS P4C60MS200ATS P4C75MS200ATS 240V List Price $ 1670.00 1770.00 1740.00 1840.00 3-Phase, 4-Wire Catalog Number P4B60MS100ATS P4B75MS100ATS P4B60MS200ATS P4B75MS200ATS 480Y/277V List Price $ 1670.00 1770.00 1740.00 1840.00 1-Phase, 3-Wire Catalog Number P4A60MS100ATS P4A75MS100ATS P4A60MS200ATS P4A75MS200ATS 480V햲 List Price $ 1400.00 1480.00 1440.00 1530.00 3-Phase, 3-Wire Catalog Number P4D60MS100ATS P4D75MS100ATS P4D60MS200ATS P4D75MS200ATS List Price $ 1590.00 1610.00 1590.00 1690.00 3-Phase, 4-Wire Catalog Number P4E60MS100ATS P4E75MS100ATS P4E60MS200ATS P4E75MS200ATS List Price $ 1930.00 2050.00 2000.00 2110.00 3-Phase, 3-Wire Catalog Number P4F60MS100ATS P4F75MS100ATS P4F60MS200ATS P4F75MS200ATS List Price $ 1790.00 1890.00 1860.00 1950.00 Type P4 Alternate Main Breaker Selection Ampere Rating 400 600 800 Catalog Number 햳 JX J6 HJ CJ SJ SH SC LX L6 HL CL SL S6 C6 M1 M2 M3 LM L1 HK HJ Maximum Interrupting Rating (KA) 240V 65 65 100 200 65 100 200 65 65 100 200 65 100 200 65 100 200 65 65 100 100 480V 35 35 65 150 35 65 150 35 35 65 150 35 65 150 35 65 100 50 50 65 65 600V 25 25 35 150 25 35 100 25 25 35 100 25 35 100 25 50 65 25 25 50 50 List Price $ STD 510. 1630. 2260. 1130. 2370. 3020. STD 120. 880. 3390. 730. 2430. 4640. STD 1130. 3260. 590. 590. 1870. 1870. Available Trip Values 200, 225, 250, 300, 350, 200, 225, 250, 300, 350, 200, 225, 250, 300, 350, 200, 225, 250, 300, 350, 200, 300, 400 200, 300, 400 200, 300, 400 450, 500, 600 250, 300, 350, 400, 450, 250, 300, 350, 400, 450, 450, 500, 600 300, 400, 500, 600 300, 400, 500, 600 300, 400, 500, 600 600, 700, 800 600, 700, 800 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 400 400 400 400 500, 600 500, 600 PANELBOARDS 10 800 Breaker Type JXD6 JD6 HJD6 CJD6 SJD6 SHJD6 SHJD6H LXD6 LD6 HLD6 CLD6 SLD6 SHLD6 SCLD6 NMX HMX LMX LMXD6 LMD6 HLMXD6 HLMD6 For inches / millimeters conversion, see Application Data section. 햲 For 600V applications, change “F” in position 3 to “G”. Price only 600V branch device. 10-48 햳 Space price covers cost of housing frame plate with blank cover plate. Provision price includes all necessary mounting hardware, less circuit breaker, and includes housing frame cover plate with breaker handle opening. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Power and Distribution Selection Branch Breaker Selection Breaker Type BL BL (HID) BAF BAFH BLF (GFCI) BLE (EQ GFI) BLEH BGL (SWN) BL (240V)R BLH (120V) HBL BLHF (GFCI) BQD NGB NEB HEB ED4 HED4 HHED6 CED6 Mounting Height Maximum Interrupting Rating (inches) (KA) Twin Single 3.75 — 3.75 — 3.75 — 3.75 3.75 3.75 3.75 3.75 3.75 3.75 — 5 5 5 5 — 5 5 — — — — — — — — — — — — 5 5 5 5 5 5 5 5 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 120V 120/240V 240V 277V 480Y/277 480V 600V 250V DC — 10 — — — — — — — 10 — — — — — — — 10 — — — — — — — 10 — — — — — — 10 10 — — — — — — 22 22 — — — — — — — 10 — — — — — — — 10 — — — — — — — 10 — — — — — — — 10 — — — — — — — 10 — — — — — — — 10 — — — — — — — — 10 — — — — — — — 10 — — — — — — 22 — — — — — — — 22 — — — — — — — 65 65 — — — — — — 65 65 — — — — — — 22 — — — — — — — — 65 — 14 — — 14 — — 65 — 14 — — 14 100 100 100 25 25 25 — 14 100 100 100 25 25 25 — 14 100 100 100 25 25 25 — 14 85 85 85 35 35 35 — 35 85 85 85 35 35 35 — 35 85 85 85 35 35 35 — 35 100 100 100 65 65 65 — 42 100 100 100 65 65 65 — 42 100 100 100 65 65 65 — 42 — — 65 — 18 18 — 30 — — 65 — 18 18 — 30 — — 65 — 18 18 — 30 25 25 — 30 — — 100 — — 100 — 25 42 — 30 — — 100 — 42 42 — 30 — — 100 — — 65 25 — — — 100 — — 65 25 — — — 100 — — 65 25 — — — 200 — — 200 — 30 — — 200 — — 200 — 30 — — 10 — — — — — — — 42 — — — — — — — 65 — — 35 — 30 — — 100 — — 65 — 30 — — 200 — — 200 — 30 — — 65 — — 35 — 30 — — 100 — — 65 — 30 — — 200 — — 200 — 30 — — 65 — — — — 30 — — — — — 35 25 30 — — 100 — — 65 35 30 — — 200 — — 150 100 30 — — 65 — — 35 25 — — — 100 — — 65 35 — — — 65 — — 35 25 30 — — 100 — — 65 35 30 — — 200 — — 150 100 30 — — 65 — — 35 25 — — — 100 — — 65 35 — 500, 600, 700, 800 — 5060. 6520.— 210. 1360. — 8.75 — — 65 — — 50 25 30 500, 600, 700, 800 — 6510. 8060.— 210. 1360. — 8.75 — — 100 — — 65 50 30 600, 700, 800 600, 700, 800 600, 700, 800 — 4590. 5930. — 5910. 7320. — 15430. 17690. 1720. 1720. 1720. — — — 8.75 8.75 8.75 — — — — — — 65 100 200 — — — — — — 35 65 100 25 50 65 30 30 30 Space price covers cost of housing frame plate with blank cover plate. Provision price includes all necessary mounting hardware, less circuit breaker, and includes housing frame cover plate with breaker handle opening. 1 to 6 poles may be mounted in 3.75" of unit space. Accessories such as shunt trips on three pole breakers require 6.25" of unit space. Discount Schedule PBSB HED4 1-pole 15–30A = 65,000 IR 35–100A = 25,000 IR For 600V applications, ED6 available at same list price. Ground fault not available on branch Sensitrip breakers. Integral ground fault not available for 3-phase, 4-wire systems. Only 3-phase, 3-wire from 3-phase, 4-wire systems. HED 4 3-Pole=42,000 IR Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-49 PANELBOARDS 210. 210. 210. 10 QJ2 QJH2 FXD6 HFD6 CFD6 FXD6 HFD6 CFD6 JXD2 JXD6 HJD6 CJD6 SJD6 SHJD6 LXD6 HLD6 CLD6 SLD6 SHLD6 LMD6, LMXD6 HLMD6, HLMXD6 NMX HMX LMX Available Provisions List Price Installed $ Space for Trip Value Ampere Ratings 1-Pole 2-Pole 3-Pole $ Future $ 15–60 100. 170. 250. 35. 55. 70 160. 190. 290. 35. 55. 80, 90, 100 — 230. 330. 35. 55. 15, 20, 30 110. 190. — 35. 55. 15, 20 220. 380. — 35. 55. 15, 20 280. 450. — 35. 55. 15, 20, 30 220. 250. — 35. 55. 40, 50, 60 — 290. — 35. 55. 15, 20, 30 200. 250.— — 35. 55. 15, 20, 30, 420. — — 35. 55. 40, 50, 60 — 530.— — 35. 55. 15, 20, 30 — 180. 230. 35. 55. 15, 20, 30, 40, 50, 60 — 210. — 35. 55. 70, 80, 90, 100 — 310. — 35. 55. 15, 20, 30, 40, 50, 60, 70 130. 250. 340. 35. 55. 80, 90, 100 — 280. 480. 35. 55. 15, 20, 30, 40, 50, 60 130. 320. 400. 35. 55. 70, 80, 90, 100 — 320. 540. 35. 55. 15, 20, 30, 250. 340. — 35. 55. 15, 20, 30, 40, 50, 60 130. 320. 400. 35. 55. 70, 80, 90, 100 200. 420. 540. 35. 55. 15—60 140. 460. 510. 35. 55. 70—100 210. 500. 660. 35. 55. 110—125 =— 820. 1190. 35. 55. 15—60 270. 450. 590. 75. 110. 70—100 300. 510. 670. 75. 110. 110—125 730. 1290. 1440. 75. 110. 15—60 390. 690. 910. 75. 110. 70—100 430. 760. 990. 75. 110. 110—125 1220. 2150. 2280. 75. 110. 15, 20, 30, 40, 50, 60 175. 570. 630. 75. 110. 70, 80, 90, 100 260. 620. 820. 75. 110. 110, 125 — 1010. 1470. 75. 110. 15, 20, 30, 40, 50, 60 490. 850. 1120. 75. 110. 70, 80, 90, 100 490. 950. 1220. 75. 110. 110, 125 — 2660. 2830. 75. 110. 15, 20, 30, 40, 50, 60 — 940. 1250. 75. 110. 70, 80, 90, 100 — 1060. 1360. 75. 110. 110, 125 — 2970. 3130. 75. 110. 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 — 1970. 2410. 75. 110. 110, 125 — 3160. 3980. 75. 110. 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 720. 940. 75. 150. 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 740. 1250. 75. 150. 70, 80, 90, 100, 125, 150, 175, 200, 225 — 1250. 1590. 75. 320. 70, 80, 90, 100, 125, 150, 175, 200, 225 — 2750. 3350. 75. 320. 70, 80, 90, 100, 125, 150, 175, 200, 225 — 3500. 4470. 75. 320. 250 — 2190. 2700. 75. 320. 250 — 3940. 4240. 75. 320. 250 — 4590. 5580. 75. 320. 200, 225, 250, 300, 350, 400 — 2150. 2350. 130. 350. 200, 225, 250, 300, 350, 400 — 2230. 2750. 130. 350. 200, 225, 250, 300, 350, 400 — 4380. 4610. 130. 350. 200, 225, 250, 300, 350, 400 — 4910. 6310. 130. 350. 200, 225, 250, 300, 350, 400 — — 5960. 130. 350. 200, 300, 400 — — 6610. 130. 350. 450, 500, 600 — 3540. 4580. 140. 640. 250, 300, 350, 400, 450, 500, 600 — 4280. 5360. 140. 640. 450, 500, 600 — 7950. 9720. 140. 640. 300, 400, 500, 600 — — 6600. 140. 640. 300, 400, 500, 600 — — 6680. 140. 640. Panelboards Power and Distribution Selection Branch Switch Selection List Price $ 3-Pole 2-Pole Ampere Rating Space Only $ 240V — Twin Mounted 30-30 30-30 30-60 60-60 60-100 100-100 200-200 965. 1020. 1020. 1020. 1315. 1410. 2510. 815. 870. 900. 900. 1050. 1050. — Provisions for Mounting Future $ Hgt (inches) NEC Fuse Clips 105. 170. 170. 170. 225. 225. 275. NEC Fuse Clips 240V — Single Mounted 30 60 100 200 200 830. 830. 1080. 1355. — — — — — 1335. 21⁄2 5 5 5 71⁄2 71⁄2 10 140. 225. 225. 225. 255. 255. 435. 260. 260. 225. 225. 275. 280. 280. 295. 295. 435. 71⁄2 71⁄2 71⁄2 10 71⁄2 Type S4/P4/SPP (10" deep) and F1/P4/FPP (10" deep) Ampere Rating List Price $ 3-Pole 2-Pole Space Only $ 600V — Twin Mounted 30-30 30-60 60-60 60-100 100-100 200-200 1400. 1400. 1400. 1525. 1610. 2895. — — — — — — Provisions for Mounting Future $ Hgt (inches) NEC Fuse Clips 225. 225. 225. 225. 225. 275. 295. 295. 295. 295. 295. 435. 225. 275. 295. 445. NEC Fuse Clips 600V — Single Mounted 100 200 1070. 1465. 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 10 — — 71⁄2 10 Blank Plates — Circuit Breaker and Vacu-Break Connecting Strap Kits — w/o Circuit Breaker For use with Sentron SPP Shallow Depth or Type S4 power panels Breaker Type Mounting Type Unit Height (inches) BL/BQD Twin 3.75 SBL 902.00 NGB Twin 3.75 SNB NEB, HEB Twin 3.75 ED Twin CED6 For use with Sentron SPP and Type S4 power panels Catalog Number List Price $ 1.25 6FPB01 196.00 2.5 6FPB02 224.00 902.00 3.75 6FPB03 224.00 SEB 902.00 5.0 6FPB05 224.00 3.75 SE6 902.00 10.0 6FPB10 302.00 Single 3.75 SCE 902.00 QJ Twin 5 SQJ 1622.00 FD6 Twin 5 SF6 1622.00 CFD6 Single 5 SCF 1622.00 JXD2,6 Single 8.75 SJ1 2254.00 SJD6 Single 8.75 SSJ1 2254.00 Catalog Number List Price $ CJD6 Single 8.75 SCJ 2254.00 SCJD6 Single 8.75 SSCJ 2254.00 LD6 Single 8.75 SL6 2668.00 SLD6 Single 8.75 SSL6 2668.00 CLD6 Single 8.75 SCL 2668.00 SCLD6 Single 8.75 SSCL 2668.00 NM, HM, LM, SNM, SHM Single 8.75 MG1 3317.00 Height (inches) Filler Plates For use with Sentron SPP and S4 power panels Breaker Type BL, BLH, HBL ED2, ED4, ED6 HED4, HHED6 Filler Plate Catalog Number List Price $ QF3 2.80 per pole Note: When a front filler plate is not completely filled with breakers, the openings in the unused space must be closed with filler plates selected from this table. Connecting Strap Kits Fusible For use with Sentron Shallow Depth or Type SPP/FPP/F1/P4 power panels 10 PANELBOARDS 10" Deep Box Unit Height (inches) Catalog Number 30–30 2.5 F602 46.00 30–60 5, 7.5 F657 46.00 30–60 5, 7.5 F657 46.00 60–60 5, 7.5 F657 46.00 60–100 5, 7.5 F657 46.00 100–100 5, 7.5 F657 46.00 100 7.5 F657 46.00 200 7.5 F657 46.00 200 10 F671 70.00 200–200 10 F672 430.00 Ampere Rating List Price $ For inches / millimeters conversion, see Application Data section. Space price covers cost of housing frame plate without breaker handle opening. Provisions include all necessary mounting hardware less breakers. 10-50 For Class J, R or T fuse clip prices, refer to page 10-51. For Class J fuse clips price 600V, 71⁄2" high units. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEC fuse clips only. stock item. Normal Discount Schedule PBSB Sentron® Panelboards Modifications and Additions Selection Type P4 When required, special constructions or additions to standard panelboards may be specified for all factory-assembled Power and Distribution Panelboards. Below and on the next page are listed many of those available for Type S4/F1/P4 panelboards. In no case do these apply to Narrow (Column) Width Lighting Panelboards or Unassembled Panelboards. 6. Subfeed or Feed-Thru Lugs (One Set Per Panel) Subfeed Double Lugs (Main Lug Panels) Unit Space (Additional Inches) Ampere List Price $ Rating 3-Phase 1-Phase MLO 400 600 800 1200 1. Type 3R / 12 Description List Price $ 32" Panelboard Construction: Single Door (Complete enclosure does not require a trim) 1175. Description List Price $ All Panels 400 600 800 1200 4. Devices Mounted on Gutter Cover — Includes Device, Mounting — Wired or Unwired See page 10–71 5. Increased Capacity Neutral Ampere Rating Phase Neutral List Price $ 400 400 600 800 600 800 1200 1200 540. 560. 795. 850. 245. 455. NA NA — — NA NA 245. 455. 615. 765. 245. 455. 615. 765. 10 10 17.5 17.5 Ampere Rating List Price $ List Price $ List Price $ Class J Class R Class T 30 60 100 200 55. 55. 85. 85. 55. 55. 85. 85. N/A N/A 180. 285. 14. Spanner Wrenches (for Vacu-Break Switches) Ampere Rating List Price $ 30-250 460. 15. Remote Control Switches Switch Type 920 7. Split Bus (Unit Space +1.25") 911 List Price $ 3. Miscellaneous Accessories 50. 70. 245. 455. NA NA Feed-Thru Lugs 2. Painted Finish See page 10–71 Nameplate — laminated, engraved Tamper-Resistant Screws — per panel 13. Fuse Clip Provisions (Add to 250 Volts or 600 Volts Unit Prices Per Switch) Phases 400A 600A 800A 1200A 1 3 350. 415. 415. 455. 570. 655. 700. 740. 8. MLO Compression Lugs — Aluminum Lugs for Use With Copper or Aluminum Cable see page 10-52. 9. Compression Lugs For Circuit Breakers see page Section 6. 10. Circuit Breaker Main — With Vacu-Break Branch Panelboards Price appropriate main breaker panel, then add list prices of desired vacu-break branches and accessories. 11. Vacu-Break Main — With Circuit Breaker Branch Panelboards Price appropriate main switch panel, then add list price of desired circuit breaker branches and accessories. 16. Ground Fault on Main Breaker Description Ampere Rating List Price $ Conventional Ground Fault includes: Ground Fault Relay, Ground Sensor, CPT and Shunt Trip 400-600 6300. Test and Monitor Panel 1070. Ground Fault add to Sensitrip III breaker price 400-600 2500. 17. Time Clocks Sangamo, Tork or Paragon time clock can be supplied, mounted in panelboard cabinet. For required increase in enclosure dimensions, consult local sales office. Price appropriate panelboard, then add list price below. Description List Price $ Time Clock (one or two pole, single or double throw contacts; three pole, . single throw) 277V maximum with plain dial . . . . . . . . . . . . . . . . . . . . . . 1070. Add for — Astronomical dial . . . . . . . . . . . . . 210. An omitting device . . . . . . . . . . . . 75. Reserve power or carryover . . . . . 2450. Space and mounting provisions only 540. 10 12. Grounding of Panelboards (No Brazed Ground Bus Offered) Ground Bus ships with the interior as standard — $115. list added for factory mounted. Non-Insulated Equipment Ground Bar Including Ground Lug . . . . . . Standard Insulated Equipment Ground Bar Including Ground Lug . . $ 395. per panel LEN Modification TAKES 20.0 unit space ≤ 800A 25" to unit space ≥ 800A 30" unit space ≤ 60 AMPS 10" unit space > 60 AMPS 15" unit space At 250 Volts — available on 5" unit only. “J” clips not required on 600V twin 200A switch. Class “R” and “T” clips not available on this switch. Class Discount Schedule PBSB Integral ground fault not available on 600 amp 3-phase, 4-wire systems. Only 3-phase, 4-wire systems. Only 3phase wire from 3-phase, 4-wire systems. Available in 90" high enclosure only. Unit space is 42 1/2" with Test and Monitor Panel; 45" without Test and Monitor Panel. Not available on Sensitrip III. required unit space — consult local sales office. Price includes increased enclosure height if required. No charge at time of order. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-51 PANELBOARDS For inches / millimeters conversion, see Application Data section. Sentron® Panelboards Modifications and Additions Selection Type S4/F1/P4 18. Circuit Breaker Accessories Breaker Type 23. Alternate Lugs Main Lug Only List Price $ Handle Blocking Device Blocks handle in either the “ON” or “OFF” position See Page 10-73 Padlocking Device — Padlocks in “OFF” position See Page 10-73 Style Amperage Rating 400 N/A Deduct 2.5" (1)#3/0 AWG - 750 kcmil or (2)#3/0 AWG - 250 kcmil Unit Space Cu or Al unit space from available unit space 125. 600 N/A (2)#3/0 AWG - 750 kcmil or (4)#3/0 - 350 kcmil 0 255. (3)#3/0 AWG - 750 kcmil Cu or Al Deduct 5.0" Unit Space from available unit space 390. (4)#3/0 AWG - 750 kcmil Cu or Al Deduct 7.5" Unit Space from available unit space 510. MLO 800 Box Height Addition Alternate Connectors 19. Ground Fault Sensing Relay Kit Equipment Protection ED Frames (30 ma) See Section 6 1000 20. Main Bus Standard main bus and ground bus is tin plated aluminum. For copper main bus, neutral bus and ground bus add from the table for each panel. Copper Neutral Bar $115. List Price. Main Bus Catalog List Price $ Number 햲 400A 600 -1200A Silver Plated Cu E 475. 1220. 1000A per sq. in Cu D 540. 1230. 750A per sq. in Al 340. B 24. Compression Lugs Style Amp Breaker Rating Type Compression Connectors Box Height Addition MLO List Price $ 400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150. 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190. 800-1200 . . . . . . . . . . . . . . . . . . . . . . . . 260. Main Breaker 22. Shunt Trip on Main and Branches 햳 Price Addition $ 400 N/A (1)250-500 kcmil or (2)#2/0 AWG - 250 kcmil Cu or Al 3-Phase 4-Wire = $150 Deduct 5.0" Unit Space 3-Phase 3-Wire = $115 from available unit space 1-Phase 3-Wire = $115 2-Wire = $115 600 N/A (2)#3/0 AWG - 500 kcmil 3-Phase 4-Wire = $200 Deduct 5.0" Unit Space 3-Phase 3-Wire = $150 from available unit space 1-Phase 3-Wire = $150 2-Wire = $150 800 N/A (3)#3/0 AWG - 500 kcmil Cu or Al 3-Phase 4-Wire = $255 Deduct 5.0" Unit Space 3-Phase 3-Wire = $190 from available unit space 1-Phase 3-Wire = $190 2-Wire = $190 1000 N/A (4)#3/0 AWG - 500 kcmil Cu or Al 3-Phase 4-Wire = $350 Deduct 5.0" Unit Space 3-Phase 3-Wire = $255 from available unit space 1-Phase 3-Wire = $255 2-Wire = $255 1200 N/A (4)#3/0 AWG - 500 kcmil Cu or Al 3-Phase 4-Wire = $350 Deduct 5.0" Unit Space 3-Phase 3-Wire = $255 from available unit space 1-Phase 3-Wire = $255 2-Wire = $255 645. 21. Copper Lugs — For Main Lug Only Panels Standard main lugs and neutral lugs are tin plated aluminum, UL listed for use with aluminum / copper cables. Price below is for one panel and includes copper lugs for main lugs and neutral lugs, and must be used with copper cables. Main Bus Ampere Rating N/A Price Addition $ 400 JD6, JXD6, HJD6, CJD6, (2)#2/0 AWG - 500 kcmil Cu or Al SJD6, SHJD6, SCJD6 0 3-Phase 4-Wire = $350 3-Phase 3-Wire = $255 1-Phase 3-Wire = $255 2-Wire = $255 PANELBOARDS 10 See Breaker Section for list prices on this option. For inches / millimeters conversion, see Application Data section. 햲 햳 Replace ”A” in position 11 of catalog number. Shunt Trip on 100A frame breakers increases mounting height to 6.25" for twin mounting. 10-52 햴 햵 Must price “D” for “B” main bus from item #20 above. See section (6) circuit breakers for 100% rated circuit breaker requirements. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Sentron Panelboards ® Type 1 Enclosure Modifications and Additions Catalog Number Selection Description Panel Adder $ After Market Price $ P4 P4 P4 P4 P4 P4 box 32 W X 10 Dp X 60 Ht. box 32 W X 10 Dp X 75 Ht. box 32 W X 10 Dp X 90 Ht. Nema 3R/12 32W X 10 Dp X 60 Ht. Nema 3R/12 32W X 10 Dp X 75 Ht. Nema 3R/12 32W X 10 Dp X 90 Ht. Standard Standard Standard 1175. 1175. 1175. 595. 595. 595. 2255. 2255. 2255. P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 P4 Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Standard Standard Standard 615. 645. 670. 615. 645. 670. 910. 935. 965. 910. 935. 965. 730. 755. 785. 730. 755. 785. 1090. 1115. 1140. 1090. 1115. 1140. Boxes PB60 PB75 PB90 WP260 WP275 WP290 Trims P460V P475V P490V P460NV P475NV P490NV P460VHG P475VHG P490VHG P460NVHG P475NVHG P490NVHG P460VD P475VD P490VD P460NVD P475NVD P490NVD P460VDD P475VDD P490VDD P460NVDD P475NVDD P490NVDD (4 (4 (4 (4 (4 (4 (4 (4 (4 (4 (4 (4 (1 (1 (1 (1 (1 (1 (1 (1 (1 (1 (1 (1 piece trim) vented 60" piece trim) vented 75" piece trim) vented 90" piece trim) unvented 60" piece trim) unvented 75" piece trim) unvented 90" piece trim) vented 60" w/Hinged gutter covers piece trim) vented 75" w/Hinged gutter covers piece trim) vented 90" w/Hinged gutter covers piece trim) unvented 60" w/Hinged gutter covers piece trim) unvented 75" w/Hinged gutter covers piece trim) unvented 90" w/Hinged gutter covers PC. Door) vented 60" PC. Door) vented 75" PC. Door) vented 90" PC. Door) unvented 60" PC. Door) unvented 75" PC. Door) unvented 90" PC. Door in door) vented 60" PC. Door in door) vented 75" PC. Door in door) vented 90" PC. Door in door) unvented 60" PC. Door in door) unvented 75" PC. Door in door) unvented 90" 290. 290. 290. 290. 290. 290. 360. 360. 360. 360. 360. 360. Flush Mounting Kits F60 F75 F90 Flush kit for P4 60" Ht. Flush kit for P4 75" Ht. Flush kit for P4 90" Ht. 145. 145. 145. Type 3R/12 Enclosures WP260 WP275 WP290 P4 3R/12 Enclosures 60" P4 3R/12 Enclosures 75" P4 3R/12 Enclosures 90" 1175. 1175. 1175. 2255. 2255. 2255. 10 PANELBOARDS For inches / millimeters conversion, see Application Data section. No price adder. Note as Mod. as Mod. charge if noted at time of order. Note No Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-53 Panelboards Type P4 Panelboards Dimensions Type 1 Box Box is symmetrical 4.375 in. [ 111 ] Box To Wall Mounting Holes 6.635 in. [169 ] Recommended Conduit Area 8.0 in. [ 203 ] Interior To Box Mounting Stubs 30.0 in. [ 254 ] 햲 60 in., 75 in., 90 in. [ 1524 ] [ 1905 ] [ 2286 ] 6.635 in. [ 169 ] 14 in. [356] 10.0 in. [ 254 ] 4.375 in. [ 111 ] 24 in. [ 610 ] 햲 32 in. [ 813 ] 햲 Type 3R and 3R/12 Box 12 in. [ 305 ] .375 in. [ 10 ] 15.81 in. [ 402 ] Mounting Bracket 햲 60 in., 75 in., 90 in. [ 1524 ] [ 1905 ] [ 2286 ] .375 in. [ 10 ] 15.81 in. [ 402 ] 32 in. 햲 [813 ] .87 in. [ 22 ] 10 34 in. [ 864 ] 10.0 in. [ 254 ] 햲 PANELBOARDS 36 in. [ 914 ] 햲 Dimensions are interior of the box. Add 5/8" to width for absolute dimension. Add 1/8" to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. 10-54 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Panelboards Type P5 Panelboards Features The P5 panel is the largest footprint distribution panel in the Siemens panel family. Even though it is our largest panel type, the P5 panel is still a space saver with it’s 38" width and 12.75" depth. With even higher main ratings to fit the application that require more or larger branch devices. This panel offers a wide array of factory assembled options and has the ability to mix breaker frames in unit space up to 1200 amps and fusible switches up to 1200 amps. Bussing options for the P5 vary from the standard temperature rated aluminum to temperature rated copper and 750 A/SI aluminum and 1000A/Si copper designs. All aluminum bussing in the P5 panel is tin-plated as a standard. Silver-plated is offered as the default for copper bus and tin as an option. Integrated time clocks, bus mounted contactors as mains or submains, split bus and subfeed lugs (up to 600 amps) are just a few of the options of this flexible panel. The P5 panel configurations defined by the unit space allowed for a given amperage, main device and box height. The P5 panel starts with a 60" high box. All of the branch devices are unit space mounted. Breakers and switches can be mixed and matched to meet customer requirements. General Weight – Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is about 10 lbs. (1 kg) per inch (54g per mm) of box height. Main Lugs 햲 Ampere Rating Connectors Suitable for Copper or Aluminum 800 1000 1200 (3) - #3/0 AWG-500 Kcmil (4) - #3/0 AWG-500 Kcmil (4) - #3/0 AWB-500 Kcmil 햲 Alternate lugs for 750 kcmil cable are available, but result in significant loss of branch unit mounting space. Consult Siemens. Gauge Steel of Boxes Fronts, Surface and Flush Dimensions in inches (mm) Gauge Steel Width Height Box Fronts 38" (965) 60 - 75 - 90 (1524, 1905, 2286) #16햲 #14 (1 piece trim) #14 Ga. (4 piece trim) 햲 16 gauge side panels, 12 gauge back support. Main Lug / Main Breaker / Main Switch Enclosure – Standard Type 1 enclosure is 38" wide x 12.75" deep. X Box Height is determined by main device and unit space. See charts for box height. Voltage – 600V AC max. 250V DC max. Amperage – 800-1200 amp Main breaker, 800-1200 amp MLO (check availability of 1600 amp with factory), 400-1200 amp Main switch. Short Circuit Rating – 200 Kaic max. symmetrical or equal to the lowest rated device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to a three-cycle rating. The three-cycle rating for the P5 panel is limited to 42 Kaic. Note that the main device may be mounted remote from the panel. 10 Bussing – The P5 panel has more options to meet market requirements. The standard bussing is temperature rated aluminum. The rating is per the requirements of UL 67 – the standard for panelboards. All aluminum bussing is tin-plated. Optional bussing for the P5 panel is: 750 A/si aluminum, temperature rated copper, and 1000 A/si copper. The copper bus option for this panel is tin-plated. PANELBOARDS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-55 Panelboards Power and Distribution Selection/Dimensions Enclosure Selection ��� Enclosure Dimension in Inches (mm) Available Unit Space in Inches (mm) H W D Main Lug Main Breaker Main Switch Type 1, 3R/12 Type 1, 3R/12 Type 1 Type 3R/12 800 / 1200A 800 / 1200A 800 / 1200A 60 (1524) 75 (1905) 90 (2286) 38 (965) 38 (965) 38 (965) 12.75 (324) 12.75 (324) 12.75 (324) 14.25 (362) 14.25 (362) 14.25 (362) 30 (762) 45 (1143) 60 (1524) 20 (508) 35 (889) 50 (1270) — 35 (889) 50 (1270) Main Breaker Unit Space Dimensions Dimensions in Inches (mm) Ampere Rating 800 1200 Breaker Type A LXD6, LMXD6, LMD6, MXD6, MD6, HMD6 CMD6, SCMD6, SHMD6, SMD6 NXD6, ND6, HND6, CND6, SND6, SHND6 13.00 (330) 10.42 (265) 13.00 (330) Main Switch Maximum Ampere Rating 400A/600A VB 800A/1200A HCP Neutral B 13.125 (333) Main Switch Connectors A 9.3 10.3 Ampere Rating B 13.125 13.125 400 600 800 1200 Connectors suitable for Copper or Aluminum (1) #3/0 AWG-500 kcmil (2) #3/0 AWG-250 kcmil (2) #3/0 AWG-500 kcmil (3) #3/0 AWG-500 kcmil (4) #3/0 AWG-500 kcmil Main Breaker Wire Bending Space Dimensions & Main Switch Main Lugs Only Wire Bending Space Lugs Standard Oversize Crimp Standard with Subfeed Standard with Feed-thru Dimensions in inches (mm) Main Lug 800A 1000A C D 1200A E Neutral 800A G 15.969 (406) 25.969 (660) 18.687 (475) 15.969 (406) 25.969 (660) 18.250 (464) 15.969 (406) 25.969 (660) 18.250 (464) 13.125 (333) 23.125 (587) 15.937 (405) — — — 13.125 (333) — — — 13.125 (333) PANELBOARDS 10 Main Lugs Only Wire Bending Space 햲 Standard trim is for space without door. Surface flush one piece trim is available for 32" (813mm) wide circuit breaker panel. 10-56 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Panelboards Power and Distribution Selection Type P5 Shown with Standard Mains, Top Fed and Surface Trim Catalog number is for aluminum main bus. For optional copper main bus change “A” in position 11 to “C”. Panels are top feed, surface mounted. For bottom feed, change “T” in position 12 to “B”. For flush mounting, change “S” in position 13 to “F”. Replace fifth and sixth position in panelboard catalog number, with alternate main breaker code. Use price adders from main breaker section table. Horizontally mounted. Main Lugs Only — shown with aluminum bus, top fed, and surface trims. Unit Space (inches) 208Y/120V 3-Phase, 4-Wire Catalog Number List Price $ 3-Phase, 4-Wire Catalog Number List Price $ 1-Phase, 3-Wire Catalog Number List Price $ 30 45 60 P5C60ML800ATS P5C75ML800ATS P5C90ML800ATS 2020.00 2130.00 2260.00 P5B60ML800ATS P5B75ML800ATS P5B90ML800ATS 2020.00 2130.00 2260.00 P5A60ML800ATS P5A75ML800ATS P5A90ML800ATS 2020.00 2130.00 2260.00 1000 30 45 60 P5C60ML101ATS P5C75ML101ATS P5C90ML101ATS 2460.00 2610.00 2750.00 P5B60ML101ATS P5B75ML101ATS P5B90ML101ATS 2460.00 2610.00 2750.00 P5A60ML101ATS P5A75ML101ATS P5A90ML101ATS 2460.00 2610.00 2750.00 1200 30 45 60 P5C60ML120ATS P5C75ML120ATS P5C90ML120ATS 2900.00 3070.00 3230.00 P5B60ML120ATS P5B75ML120ATS P5B90ML120ATS 2900.00 3070.00 3230.00 P5A60ML120ATS P5A75ML120ATS P5A90ML120ATS 2900.00 3070.00 3230.00 Maximum Panel Ampere Rating Unit Space (inches) 240 3-Phase, 3-Wire Catalog Number List Price $ 3-Phase, 4-Wire Catalog Number List Price $ 1-Phase, 3-Wire Catalog Number List Price $ 30 45 60 P5D60ML800ATS P5D75ML800ATS P5D90ML800ATS 1610.00 1720.00 1800.00 P5E60ML800ATS P5E75ML800ATS P5E90ML800ATS 2020.00 2130.00 2260.00 P5F60ML800ATS P5F75ML800ATS P5F90ML800ATS 1610.00 1720.00 1800.00 1000 30 45 60 P5D60ML101ATS P5D75ML101ATS P5D90ML101ATS 1960.00 2070.00 2150.00 P5E60ML101ATS P5E75ML101ATS P5E90ML101ATS 2460.00 2610.00 2750.00 P5F60ML101ATS P5F75ML101ATS P5F90ML101ATS 1960.00 2070.00 2150.00 1200 30 45 60 P5D60ML120ATS P5D75ML120ATS P5D90ML120ATS 2300.00 2430.00 2550.00 P5E60ML120ATS P5E75ML120ATS P5E90ML120ATS 2900.00 3070.00 3230.00 P5F60ML120ATS P5F75ML120ATS P5F90ML120ATS 2300.00 2430.00 2550.00 Maximum Panel Ampere Rating 800 800 240/120V 120/240V or 250 Vdc Max 480V 480Y/277V Main Circuit Breaker — shown with aluminum bus, top fed, and surface trims. Unit Space (inches) 208Y/120V 3-Phase, 4-Wire Catalog Number List Price $ 3-Phase, 4-Wire Catalog Number List Price $ 1-Phase, 3-Wire Catalog Number List Price $ 21.25 36.25 51.25 P5C60M1800ATS P5C75M1800ATS P5C90M1800ATS 8140.00 8590.00 9040.00 P5B60M1800ATS P5B75M1800ATS P5B90M1800ATS 8140.00 8590.00 9040.00 P5A60M1800ATS P5A75M1800ATS P5A90M1800ATS 6820.00 7190.00 7570.00 1200 20 35 50 P5C60N1120ATS P5C75N1120ATS P5C90N1120ATS 12900.00 13620.00 14350.00 P5B60N1120ATS P5B75N1120ATS P5B90N1120ATS 12900.00 13620.00 14350.00 P5A60N1120ATS P5A75N1120ATS P5A90N1120ATS 11590.00 12230.00 12880.00 Maximum Panel Ampere Rating Unit Space (inches) 240 3-Phase, 4-Wire Catalog Number List Price $ 3-Phase, 4-Wire Catalog Number List Price $ 1-Phase, 3-Wire Catalog Number List Price $ 21.25 36.25 51.25 P5D60M1800ATS P5D75M1800ATS P5D90M1800ATS 7720.00 8160.00 8590.00 P5E60M1800ATS P5E75M1800ATS P5E90M1800ATS 8140.00 8590.00 9040.00 P5F60M1800ATS P5F75M1800ATS P5F90M1800ATS 7720.00 8160.00 8590.00 20 35 50 P5D60N1120ATS P5D75N1120ATS P5D90N1120ATS 12310.00 13010.00 13680.00 P5E60N1120ATS P5E75N1120ATS P5E90N1120ATS 12900.00 13620.00 14350.00 P5F60N1120ATS P5F75N1120ATS P5F90N1120ATS 12310.00 13010.00 13680.00 Maximum Panel Ampere Rating 800 800 1200 240/120V 120/240V or 250 Vdc Max 480V 480Y/277V 10 PANELBOARDS For inches / millimeters conversion, see Application Data section. Alternate main breaker requires additional 1.25" unit space. For 600V, change “F” in position 3 to “G”. Price only branch breakers with 600V ratings. Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-57 Panelboards Power and Distribution Selection Main Fusible Switch (fuses not included) Maximum Panel Ampere Rating 400 600 800 1200 Maximum Panel Ampere Rating 400 600 800 1200 Unit Space (inches) 20 40 25 40 28.75 43.75 28.75 43.75 Unit Space (inches) 25 40 25 40 28.75 43.75 28.75 43.75 208Y/120V 240/120V 120/240V 3-Phase, 4-Wire Catalog Number P5C75MS400ATS P5C90MS400ATS P5C75MS600ATS P5C90MS600ATS P5C75MS800ATS P5C90MS800ATS P5C75MS120ATS P5C90MS120ATS 240V List Price $ 3480.00 3660.00 4920.00 5170.00 7640.00 8030.00 9770.00 10290.00 3-Phase, 4-Wire Catalog Number P5B75MS400ATS P5B90MS400ATS P5B75MS600ATS P5B90MS600ATS P5B75MS800ATS P5B90MS800ATS P5B75MS120ATS P5B90MS120ATS 480Y/277V List Price $ 3480.00 3660.00 4920.00 5170.00 7640.00 8030.00 9770.00 10290.00 1-Phase, 3-Wire Catalog Number P5A75MS400ATS P5A90MS400ATS P5A75MS600ATS P5A90MS600ATS P5A75MS800ATS P5A90MS800ATS P5A75MS120ATS P5A90MS120ATS 480V List Price $ 2790.00 2940.00 4170.00 4380.00 6290.00 6610.00 8070.00 8500.00 3-Phase, 3-Wire Catalog Number P5D75MS400ATS P5D90MS400ATS P5D75MS600ATS P5D90MS600ATS P5D75MS800ATS P5D90MS800ATS P5D75MS120ATS P5D90MS120ATS List Price $ 3480.00 3660.00 4920.00 5170.00 7640.00 8030.00 9770.00 10290.00 3-Phase, 4-Wire Catalog Number P5E75MS400ATS P5E90MS400ATS P5E75MS600ATS P5E90MS600ATS P5E75MS800ATS P5E90MS800ATS P5E75MS120ATS P5E90MS120ATS List Price $ 4650.00 4900.00 5190.00 5480.00 7650.00 8050.00 9770.00 10290.00 3-Phase, 3-Wire Catalog Number P5F75MS400ATS P5F90MS400ATS P5F75MS600ATS P5F90MS600ATS P5F75MS800ATS P5F90MS800ATS P5F75MS120ATS P5F90MS120ATS List Price $ 3890.00 4100.00 4920.00 5180.00 7250.00 7620.00 9240.00 9730.00 Alternate Main Breaker Selection Ampere Rating 800 800 1200 Maximum IR (KA) Symmetrical Amperes Catalog Numbe r M1 M2 M3 LMXD6 HD M6 HM CM SM S8 C8 N1 N2 N3 N6 HN CN SN SI CI 240V AC 65 100 200 65 100 65 100 200 65 100 200 65 100 200 65 100 200 65 100 200 480V AC 35 65 100 50 65 50 65 100 50 65 100 35 65 100 50 65 100 50 65 100 List Price $ STD 1130. 3260. 590. 1870. 1710. 2370. 4370. 5860. 3540. 5860. STD 1130. 2500. 1190. 2370. 2500. 2440. 4080. 5080. 600V AC 25 50 65 25 50 25 50 50 25 50 65 25 50 65 25 50 50 25 50 65 Available Trip Values 600, 700, 800 600, 700, 800 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 500, 600, 700, 800 600, 700, 800 600, 700, 800 500, 600, 800 800, 900, 1000, 1200 800, 900, 1000, 1200 800, 900, 1000, 1200 800, 900, 1000, 1200 800, 900, 1000, 1200 900, 1000, 1200 900, 1000, 1200 800, 900, 1000, 1200 800, 900, 1000, 1200 PANELBOARDS 10 1200 Breaker Type NMX HMX LMX LMD6 HLMD6 MD6 HMD6 CMD6 SMD6 SHMD6 SCMD6 NNX HNX LNX ND6 HND6 CND6 SND6 SHND6 SCND6 For inches / millimeters conversion, see Application Data section. For 600V, change “F” in position 3 to “G”. Price only branch breakers with 600V ratings. ground fault, see page 10-62. For 10-58 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Replace “MB” in catalog number with code letter. Use adders from this table. 800 and 1200 ampere switches have “L” class fuse provisions (Type HCP). Discount Schedule PBSB Panelboards Power and Distribution Selection Type P5 Branch Circuit Breakers Space price covers cost of housing frame plate with blank cover plate. Provision price includes all necessary mounting hardware, less circuit breaker, and includes housing frame cover plate with breaker handle opening. Discount Schedule PBSB Mounting Height Maximum Interrupting Rating (inches) (KA) Twin Single 120V 120/240V 240V 277V 480Y/277 — — 10 — — — 3.75 — — 10 — — — — — 10 — — — 3.75 — — 10 — — — 3.75 — 10 10 — — — 3.75 — 22 22 — — — — — 10 — — — 3.75 — — 10 — — — 3.75 — — 10 — — — — — 10 — — — 3.75 3.75 — — 10 — — — 3.75 — — 10 — — — — — — 10 — — 3.75 — — — 10 — — — 22 — — — 3.75 — 3.75 — — 22 — — — — — 22 — — — — — 22 — — — 3.75 — — 22 — — — — — 22 — — — 3.75 — — 22 — — — — — — 65 — 14 3.75 — — — 65 — 14 100 100 100 25 25 3.75 — 100 100 100 25 25 100 100 100 25 25 85 85 85 35 35 3.75 — 85 85 85 35 35 85 85 85 35 35 100 100 100 65 65 3.75 — 100 100 100 65 65 100 100 100 65 65 — — — 65 — 18 3.75 — — — 65 — 18 — — — 65 — 18 25 — — — 100 3.75 — — — 100 — 25 — — — 100 — 42 — — — 100 — — 3.75 — — — 100 — — — — — 100 — — — — — 200 — — 3.75 — — — — — — — 5 5 — — 10 — — 5 5 — — 22 — — 5 5 — — 42 — — 5 5 — — 65 — — 5 5 — — 100 — — — 5 — — 200 — — 5 5 — — 65 — — 5 5 — — 100 — — — 5 — — 200 — — 8.75 8.75 — — 65 — — 8.75 8.75 — — — — — 8.75 8.75 — — 100 — — — 8.75 — — 200 — — — 8.75 — — 65 — — — 8.75 — — 100 — — — — — — 65 — — — — — 100 — — 8.75 — — — — 200 — — — — — — 65 — — — 8.75 — — 100 — — — 8.75 — — 65 — — — 8.75 — — 100 — — — — — — 65 — — — — — 100 — — 10 — — — — 200 — — — — — — 65 — — — 10 — — 100 — — — — — — 65 — — — — — 100 — — 10 — — — — 200 — — — — — — 65 — — — 10 — — 100 — — — 8.75 — — 65 — — — 8.75 — — 100 — — — 8.75 — — 200 — — — 10 — — 65 — — — 10 — — 100 — — — 10 — — 200 — — 1 For Accessories Ground to 6 poles may be mounted in 3.75" of unit space. such as shunt trips on three pole breakers require 6.25" of unit space. HED4 1-pole 15–30A = 65,000 IR 35–100A = 25,000 IR 480V 600V 250V DC — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 14 — — 14 25 — 14 25 — 14 25 — 14 35 — 35 35 — 35 35 — 35 65 — 42 65 — 42 65 — 42 18 — 30 18 — 30 18 — 30 42 — 30 42 — 30 42 — 30 65 25 — 65 25 — 65 25 — 200 — 30 — — — — — — — — — — — — 35 — 30 65 — 30 200 — 30 35 — 30 65 — 30 200 — 30 — — 30 35 25 30 65 35 30 150 100 30 35 25 — 65 35 — 35 25 30 65 35 30 150 100 30 35 25 — 65 35 — 50 25 30 65 50 30 35 25 30 65 35 30 150 100 30 35 25 — 65 50 — 50 25 30 65 35 30 150 100 30 35 25 — 65 50 — 35 25 30 65 50 30 100 65 30 35 25 30 65 50 30 100 65 30 600V applications, ED6 available at same list price. fault is not available on branch Sensitrip breakers. HED4 3-Pole = 42,000 IR Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-59 PANELBOARDS For inches / millimeters conversion, see Application Data section. Provisions Space for $ Future $ 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55. 35. 55 35. 55. 35. 55. 35. 55. 35. 50. 35. 50. 35. 50. 35. 50. 35. 50. 35. 50. 35. 50. 35. 50. 35. 50. 75. 110. 75. 110. 75. 110. 75. 110. 75. 110. 75. 110. 75. 110. 75. 110. 75. 110. 75. 110. 75. 110. 75. 150. 75. 150. 75. 150. 75. 320. 75. 320. 75. 320. 75. 320. 75. 320. 75. 320. 130. 350. 130. 350. 130. 350. 130. 350. 130. 350. 130. 350. 140. 640. 140. 640. 140. 640. 140. 640. 140. 640. 210. 1380. 210. 1380. 210. 1380. 210. 1380. 210. 1380. 210. 1380. 210. 1380. 220. 1560. 220. 1560. 220. 1560. 220. 1560. 220. 1560. 210. 1720. 210. 1720. 210. 1720. 210. 1720. 210. 1720. 210. 1720. 10 Available List Price Installed $ Trip Value Ampere Ratings 1-Pole 2-Pole 3-Pole 15, 20, 30, 40, 50, 60 100. 170. 250. BL 70 160. 190. 290. 80, 90, 100 — 230. 330. BL (HID) 15, 20, 30 110. 190. — BAF (arc fault) 15, 20 220. 380. — BAFH(arc fault) 15, 20 280. 450. — 15, 20, 30 220. 250. — BLF (GFCI) 40, 50, 60 — 290. — BLE (EQ GFI) 15, 20, 30 200. 250. — 15, 20, 30 420. 530. — BLEH 40, 50, 60 — 530. — BGL (SWN) 15, 20, 30 — 180. 230. 15, 20, 30, 40, 50, 60, 70 — 210. — BL (240V)R 70, 80, 90, 100 — 310. — 15, 20, 30, 40, 50, 60 130. 240. 340. BLH (120V) 70 — 340. 380. 80, 90, 100 225. 280. 480. 15, 20, 30 250. 340. — BLHF (GFCI) 40, 50, 60 — — — 15, 20, 30, 40, 50, 60 130. 320. 400. HBL 70, 80, 90, 100 — 420. 540. 15, 20, 30, 40, 50, 60 130. 320. 400. BQD 70, 80, 90, 100 200. 420. 540. 15—60 140. 460. 510. NGB 70—100 210. 500. 660. 110—125 — 820. 1190. 15—60 270. 450. 590. NEB 70—100 300. 510. 670. 110—125 730.= 1290. 1440. 15—60 390. 690. 910. HEB 70—100 430. 760. 990. 110—125 1220.= 2150. 2280. 15, 20, 30, 40, 50, 60 175. 570. 630. ED4 70, 80, 90, 100 260. 620. 820. 110, 125 — 1010. 1470. 15, 20, 30, 40, 50, 60 490. 850. 1120. HED4 70, 80, 90, 100 490. 950. 1220. 110, 125 — 2660. 2830. 15, 20, 30, 40, 50, 60 — 940. 1250. HHED6 70, 80, 90, 100 — 1060. 1360. 110, 125 — 2970. 3130. 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 — 1970. 2410. CED6 110, 125 — 3160. 3980. QJ2 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 720. 940. QJH2 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 740. 1250. QJ2H 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 — 1030. 1540. FXD6 70, 80, 90, 100, 125, 150, 175, 200, 225 — 1250. 1590. HFD6 70, 80, 90, 100, 125, 150, 175, 200, 225 — 2750. 3350. CFD6 70, 80, 90, 100, 125, 150, 175, 200, 225 — 3500. 4470. FXD6 250 — 2190. 2700. HFD6 250 — 3940. 4240. CFD6 250 — 4590. 5580. JXD2 200, 225, 250, 300, 350, 400 — 2150. 2350. JXD6 200, 225, 250, 300, 350, 400 — 2230. 2750. HJD6 200, 225, 250, 300, 350, 400 — 3690. 4380. CJD6 200, 225, 250, 300, 350, 400 — 4910. 6310. SJD6 200, 225, 250, 300, 350, 400 — — 5960. SHJD6 200, 300, 400 — — 6610. LXD6 450, 500, 600 — 3540. 4580. HLD6 250, 300, 350, 400, 450, 500, 600 — 4280. 5360. CLD6 450, 500, 600 — 6600. 9720. 300, 400, 500, 600 — — 6600. SLD6 SHLD6 300, 400, 500, 600 — — 6680. LMD6 500, 600, 700, 800 — 5060. 6520. HLMD6 500, 600, 700, 800 — 6510. 8060. MD6 500, 600, 700, 800 — 7450. 9500. HMD6 500, 600, 700, 800 — 9320. 10870. CMD6 500, 600, 700, 800 — 8010. 12160. SMD6 600, 700, 800 — — 10260. SHMD6 600, 700, 800 — — 11030. ND6 800, 900, 1000, 1200 — — 13040. HND6 800, 900, 1000, 1200 — — 13670. CND6 800, 900, 1000, 1200 — — 17690. SND6 900, 1000, 1200 — — 13030. SHND6 800, 1000, 1200 — — 13900. NMX 600, 700, 800 — 4590. 5930. HMX 600, 700, 800 — 5910. 7320. LMX 600, 700, 800 — 7280. 11060. NNX 800, 900, 1000, 1200 — 8910. 11850. HNX 800, 900, 1000, 1200 — 10490. 12430. LNX 800, 900, 1000, 1200 — 15430. 17690. Breaker Type Panelboards Power and Distribution Selection/Dimensions Branch Switch Selection (fuses not included) Ampere Rating List Price $ 3-Pole 2-Pole Space Only $ Provisions for Future $ 240V — Twin Mounted 30-30 30-30 30-60 60-60 60-100 100-100 200-200 965. 1020. 1020. 1020. 1315. 1410. 2510. 815. 870. 880. 900. 1040. 1050. —– NEC Fuse 105. 170. 170. 170. 225. 225. 275. — — — — 2015. 2015. 4740. 4740. 5110. Clips ⁄2 140. 225. 225. 225. 255. 255. 435. 2 5 5 5 71⁄2 71⁄2 10 — — 225. 275. 225. 475. 475. 680. 680. 71⁄2 71⁄2 71⁄2 10 71⁄2 15 15 161⁄4 161⁄4 280. 280. 295. 435. 295. 475. 475. 680. 680. Ampere Rating List Price $ 3-Pole 2-Pole Space Only $ Provisions for Future $ 1400. 1400. 1400. 1525. 1610. 2895. — — — — — — 225. 225. 225. 225. 225. 275. 295. 295. 295. 295. 295. 435. — — — — — — — — 71⁄2 71⁄2 71⁄2 71⁄2 71⁄2 10 NEC Fuse Clips 600V — Single Mounted 100 1070. 200 1465. 400 3170. 400 (HCP) 9295. 600 3860. 600 (HCP) 9295. 800 (HCP) 9295. 1200 (HCP) 11100. Mounting Height (inches) NEC Fuse Clips 600V — Twin Mounted 30-30 30-60 60-60 60-100 100-100 200-200 1 NEC Fuse Clips 240V — Single Mounted 030 830. 060 830. 0100 1080. 0200 1355. 0200 — 0400 2545. 0600 3540. 0800 (HCP) 9295. 1200 (HCP) 11100. Mounting Height (inches) 225. 275. 475. 680. 475. 680. 680. 680. 295. 445. 475. 680. 475. 680. 680. 680. 71⁄2 10 15 15 161⁄4 161⁄4 Branch Breaker Side Gutter Inches (mm) Reference Letter A 14.0 (356) 10.0 (254) 9.5 (242) 8.25 (210) 8.125 (207) 7.615 (193) 11.769 (299) 13.425 (341) 8.956 (227) 13.0 (330) 12.0 (305) 10.0 (254) 8.0 (203) 10.5 (267) 9.3 (236) 10.3 (262) 13.0 (330) 10.75 (273) B C D E F G H I J K M N O P Q R S T U V W BL BLH, HBL, BQO ED4, ED6 HED4, HHED6 QJ2, QJH2 QJ2H FXD6, FD6 HFD6 JXD6, JD6 HJD6 CED6 BL BLH, HBL, BQO ED4, ED6 HED4, HHED6 QJ2, QJH2 QJ2H FXD6, FD6 HFD6 JXD6, JD6 HJD6 CED6 CFD6 JXD6, JD6, LXD6, LD6, SLD6 SJD6, SHJD6, HLD6, SHLD6 CJD6, CLD6 MD6, ND6, CMD6, CND6, HMD6, HND6, NNX, HNX, LNX SMD6, SND6 LMD6, HLMD6, NMX, HMX, LMX VB 2.5" 30A Gutter VB 2.5" 30A Gutter VB 5" 30–60A Gutter VB 5" 30–60A Gutter VB 7.5" 60–100A Gutter VB 7.5" 60–100A Gutter VB 10" 200A Gutter VB 10" 200A Gutter VB 7.5" 100A Gutter VB 10" 200A Gutter VB 15" 400–600A Gutter HCP 16–25" 400–1200A Gutter NGB NGB NEB, HEB NEB, HEB A B C D E F G H I J K M N O P Q R S T U V W PANELBOARDS 10 A B C D E F G H I J, M, N, O K P Q R, S T U V W Panel Width 38 in. Inches (mm) For inches / millimeters conversion, see Application Data section. 10-60 Space price covers cost of housing frame plate without breaker handle opening. Provisions include all necessary mounting hardware less breakers. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog For Class J, R or T fuse clip prices, refer to page 10-62. 800 and 1200 ampere switches have class “L” fuse provisions. (Type HCP). NEC fuse clips only. Discount Schedule PBSB Panelboards Power and Distribution Selection/Dimensions Types P5 and SPP/FPP, F2 (12 3/4" deep) Connecting Strap Kits Circuit Breaker Connecting Strap Kits Fusible For use with Sentron Deep or Type S5 power panels 12.75" Deep Box Blank Plates Circuit Breaker and Vacu-Break For use with Sentron FPP Deep or Type F2/P5 power panels For use with Sentron SPP and Type S5 power panels Catalog Number List Price $ 1.25 6FPB01 196.00 2.5 6FPB02 224.00 254.00 3.75 6FPB03 224.00 F657D 254.00 5.0 6FPB05 224.00 5, 7.5 F657D 254.00 10.0 6FPB10 302.00 60–100 5, 7.5 F657D 254.00 1622.00 100–100 5, 7.5 F657D 254.00 1622.00 100 7.5 F657D 254.00 SCFD 1622.00 200 7.5 F657D 254.00 8.75 SJ1D 2254.00 200 10 F671D 393.00 Twin 8.75 SJ2D 2488.00 200–200 10 F672D 430.00 SJD6 Single 8.75 SSJ1D 2488.00 400–600 15 F6150D 186.00 CJD6 Single 8.75 SCJD 2254.00 800–1200 16.25 F6162D 1366.00 SCJD6 Single 8.75 SSCJD 2254.00 LD6 Single 8.75 SL6D 2668.00 SLD6 Single 8.75 SSL6D 2668.00 CLD6 Single 8.75 SCLD 2668.00 SCLD6 Single 8.75 SSCLD 2668.00 8.75 Unit Height (inches) 12. 75" Deep Box Unit Height (inches) Catalog Number 30–30 2.5 F602D 210.00 902.00 30–30 5, 7.5 F657D SNBD 902.00 30–60 5, 7.5 3.75 SE6D 902.00 60–60 Single 3.75 SCED 882.00 QJ Twin 5. SQJD FD6 Twin 5. SF6D CFD6 Single 5. JXD2, JXD6 Single JXD2, JXD6 Breaker Type Catalog List Number Price $ Mounting BL /BQD Twin 3.75 SBLBD 902.00 NGB Twin 3.75 SNBD NEB, HEB Twin 3.75 ED Twin CED6 LMD6, HLMD6 Single SLM1D 3240.00 MD6, HMD6, CMD6 Single 10. SMND 3847.00 SMD6, SHMD6 Single 10. SSMND 4097.00 ND6, HND6 Single 10. SMND SND6, SHND6, SCND6 Single 10. SSMND 4097.00 NM, HM, LM, SNM, SHM Single NN, HN, LN, SNN, SHN Single 8.75. 10. Ampere Rating List Price $ Height (inches) Filler Plates For use with Sentron SSP and Type S5 power panels Breaker Type BL, BLH, HBL, BQD, ED2, ED4, ED6, HED4, HED6, HHED6 Filler Plate Catalog Number List Price $ QF3 2.80 per pole 3847.00 MG1D 3317.00 NG1D 3939.00 10 Normal stock item. cover plate and mounting hardware, less circuit breaker. Also fits Types FCI, FCII, SB1 and SB2 switchboards. 800 – 1200 amp units are HCP switch. PANELBOARDS For inches / millimeters conversion, see Application Data section. Note: When a front filler plate is not completely filled with breakers, the openings in the unused space must be closed with filler plates selected from this table. Includes Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-61 Sentron® Panelboards Modifications and Additions Selection Type P5 When required, special constructions or additions to standard panelboards may be specified for all factoryassembled Power and Distribution Panelboards. Below and on the next page are listed many of those available for Type S5 panelboards. In no case do these apply to Narrow (Column) Width Lighting Panelboards or Unassembled Panelboards. 1. Type 3R/12 List Price $ Description 38" Panelboard Construction: Single Door . . . 1485. Complete enclosure does not require a trim. 2. Painted Finish see page 10-72. 3. Miscellaneous Accessories List Price $ All Description Panels Nameplate — laminated, engraved . . . . 50. Tamper-Resistant Screws – per panel . . 70. 7. MLO Compression Lugs — Aluminum Lugs for Use With Copper or Aluminum Cable Available as main lugs and neutral lug. Price includes required aluminum compression lugs. See page 10-64. 8. Compression Lugs For Circuit Breakers — See Section 6. 9. Circuit Breaker Main — With Vacu-Break Branch Panelboards Price appropriate main breaker panel, then add list prices of desired vacu-break branches and accessories. 10. Vacu-Break Main — With Circuit Breaker Branch Panelboards Price appropriate main switch panel, then add list price of desired circuit breaker branches and accessories. 11. Grounding of Panelboards Non-Insulated Equipment Ground Bus Including Ground Lug . . . . . . .Standard Insulated Equipment Ground Bus Including Ground Lug . . .$15. per panel List Price $ 4. Devices Mounted on Gutter Cover — Includes Device, Mounting — Wired or Unwired see page 10-72 Description 5. Feed-Thru Lugs (One Set Per Panel) BFI/BFT — Blown Fuse/Blown Fuse Trip Ampere Rating List Price $ 400 600 800 1200 245. 455. 615. 765. Unit Space (Additional inches) 10 10 17.5 17.5 6. Split Bus List Price $ 2240. BFI — Blown Fuse 1200. GF/BFT — Ground Fault & Blown Fuse Trip 3-Phase 1-Phase MLO 245. 455. 615. 765. ST W/CPT 800A 1200A Unit Space (Additional inches) 1-Phase 3-Phase 570. 655. 700. 740. 1.25 1.25 BFT — Blown Fuse Trip 1985. GF w/Test Panel 10810. 13. Fuse Clip Provisions (Add to 250 Volts or 600 Volts Unit Prices Per Switch) Ampere Rating List Price $ List Price $ List Price $ Class J Class R Class T 30 60 100 200 400, 600 55. 55. 85. 85. 85. 55. 55. 85. 85. 85. N/A N/A 160. 180. 285. PANELBOARDS 10 Phases 3180. 10810. For inches / millimeters conversion, see Application Data section. For use on main lug, main breaker or main switch panels without subfeed breakers. 10-62 For increase in panelboard height — Consult local sales office. Price includes increased enclosure height if required. Ground bar not installed in box. For factory installation, add $100. List Price per panel. Price 600 Volt 71/2" high units. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog At 250 Volts — available on 5" unit only. Class “J” clips not required on 600V twin 200A switch. Class “R” and “T” clips not available on this switch. Discount Schedule PBSB Sentron® Panelboards Modifications and Additions Type P5 14. Remote Control Switches Switch Type 920 911 LEN Modification TAKES 20.0 unit space ≤ 800A 25" to unit space ≥ 800A 30" unit space ≤ 60 AMPS 10" unit space > 60 AMPS 15" unit space 15. Ground Fault on Main Breaker Ampere Rating Description List Price $ Fault Conventional Ground includes: Ground Fault Relay, Ground Sensor, CPT and Shunt Trip 800-1200 7330. Test and Monitor Panel 1070. Ground Fault add to Sensitrip III breaker price (takes 5" of unit space) 800-1200 2500. 16. Time Clocks Sangamo, Tork or Paragon time clock can be supplied, mounted in panelboard cabinet. For required increase in enclosure dimensions, consult local sales office. Price appropriate panelboard, then add list price below. Description List Price $ Time Clock (one or two pole, single or double throw contacts; three pole, single throw) 277V maximum with plain dial 1070. Add for — Astronomical dial 210. An omitting device 75. Reserve power or carryover 2450. Space and mounting provisions only 540. Selection 19. Main Bus Standard main bus and ground bus are tin plated aluminum. For copper main bus, neutral bus and ground bus add from the table for each panel. Copper Neutral Bar $115. List Price. Main Bus Catalog 800–1200 Number Ampere $ Silver Plated Copper E 1220. 1000A per sq. in. Copper D 1070. 750A per sq. in. Aluminum B 645. 20. Copper Lugs — For Main Lug Only Panels Standard main lugs and neutral lugs are tin plated aluminum, UL listed for use with aluminum / copper cables. Price below is for one panel and includes copper lugs for main lugs and neutral lugs, and must be used with copper cables. Main Bus Ampere Rating List Price $ 800-1200 225. 21. Shunt Trip on Main and Branches See Breaker Section for list price on this option. 22. Spanner Wrenches (for Vacu-Break Switches) Ampere Rating List Price $ 30-250 460. 23. Alternate Lugs Style 17. Circuit Breaker Accessories Handle Blocking Device Blocks handle in either the “ON” or “OFF” position — See page 10-73 Padlocking Device — Padlocks in “OFF” position — See page 10-73 MLO 18. Ground Fault Sensing Relay Kit Equipment Protection ED Frames (30 ma) — See page 10-73 Main Switch VacuBreak Amperage Rating Alternate Connectors Box Height Addition Price Addition $ 800 (3)#3/0 AWG - 750 Kcmil Cu or Al Deduct 5.0" Unit Space from available unit space 390. 1000 (4)#3/0 AWG - 750 Kcmil Cu or Al Deduct 7.5" Unit Space from available unit space 510. 1200 (4)#3/0 AWG - 750 Kcmil Cu or Al Deduct 7.5" Unit Space from available unit space 510. 400 (1)#3/0 AWG - 750 Kcmil Cu or Al or (2)#3/0 AWG 250 Kcmil Cu or Al Deduct 3.75" Unit Space from available unit space 125. 10 Available in 90" high enclosure only. Unit space is 42 1/2" with Test and Monitor Panel; 45" without Test and Monitor Panel. Not available on Sensitrip III. Discount Schedule PBSB For required unit space — consult local sales office. Price includes increased enclosure height if required. Replace ”A” in position 11 of catalog number. Shunt Trip on 100A frame breakers increases mounting height to 6.25" for twin mounting. Must price “D” or “B” from item #19 above. See section (6) circuit breakers for 100% rated circuit breaker requirements. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-63 PANELBOARDS Panelboards Modifications and Additions Selection 24. Compression Lugs Style Amp Rating 800 MLO Breaker Type Compression Connectors Box Height Addition Price Addition $ N/A (3)#3/0 AWG - 500 Kcmil Cu or Al Deduct 5.0" Unit Space from available unit space 3-Phase 4-Wire = $255 3-Phase 3-Wire = $190 1-Phase 3-Wire = $190 2-Wire = $190 3-Phase 4-Wire = $350 3-Phase 3-Wire = $255 1-Phase 3-Wire = $255 2-Wire = $255 1000 N/A (4)#3/0 AWG - 500 Kcmil Cu or Al Deduct 5.0" Unit Space from available unit space 1200 N/A (4)#3/0 AWG - 500 Kcmil Cu or Al Deduct 5.0" Unit Space from available unit space 3-Phase 4-Wire = $350 3-Phase 3-Wire = $255 1-Phase 3-Wire = $255 2-Wire = $255 MD6, HMD6, CMD6, SMD6, SHMD6, SCMD6 (3)#2/0 AWG - 500 Kcmil Cu or Al 0 3-Phase 4-Wire = $305 3-Phase 3-Wire = $235 1-Phase 3-Wire = $235 2-Wire = $235 ND6, HND6, CND6, SND6, SHND6, SCND6 (4)#250 - 500 Kcmil Cu or Al 0 3-Phase 4-Wire = $305 3-Phase 3-Wire = $235 1-Phase 3-Wire = $235 2-Wire = $235 800 Main Breaker (S5 Only) 1200 Type 1 Enclosure Modifications and Additions P5 Panel Adder $ Description After Market Price $ Boxes PB860 PB875 PB890 PBD860 PBD875 PBD890 P5 P5 P5 P5 P5 P5 box box box box box box 38 38 38 38 38 38 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 P5 Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std (4 (4 (4 (4 (4 (4 (4 (4 (4 (4 (4 (4 (1 (1 (1 (1 (1 (1 (1 (1 (1 (1 (1 (1 W W W W W W X X X X X X 12.75 12.75 12.75 14.50 14.50 14.50 Dp Dp Dp Dp Dp Dp X X X X X X 60 75 90 60 75 90 Ht. Ht. Ht. Ht. Ht. Ht. Standard Standard Standard 595. 595. 595. 615. 615. 615. Trims PANELBOARDS 10 P560V P575V P590V P560NV P575NV P590NV P560VHG P575VHG P590VHG P560NVHG P575NVHG P590NVHG P560VD P575VD P590VD P560NVD P575NVD P590NVD P560VDD P575VDD P590VDD P560NVDD P575NVDD P590NVDD piece trim) vented 60" piece trim) vented 75" piece trim) vented 90" piece trim) unvented 60" piece trim) unvented 75" piece trim) unvented 90" piece trim) vented 60" w/Hinged gutter covers piece trim) vented 75" w/Hinged gutter covers piece trim) vented 90" w/Hinged gutter covers piece trim) unvented 60" w/ Hinged gutter covers piece trim) unvented 75" w/Hinged gutter covers piece trim) unvented 90" w/Hinged gutter covers PC. Door) vented 60" Use 14.5" deep box PC. Door) vented 75" Use 14.5" deep box PC. Door) vented 90" Use 14.5" deep box PC. Door) unvented 60" Use 14.5" deep box PC. Door) unvented 75" Use 14.5" deep box PC. Door) unvented 90" Use 14.5" deep box PC. Door in door) vented 60" Use 14.5" deep box PC. Door in door) vented 75" Use 14.5" deep box PC. Door in door) vented 90" Use 14.5" deep box PC. Door in door) unvented 60" Use 14.5" deep box PC. Door in door) unvented 75" Use 14.5" deep box PC. Door in door) unvented 90" Use 14.5" deep box Standard Standard Standard 290. 290. 290. 290 . 290 . 290 . 170. 170. 170. 170 . 170 . 170 . 360. 360. 360. 360 . 360 . 360 . 615. 645. 670. 615. 645. 670. 910. 935. 965. 910. 935. 965. 730. 760. 785. 730. 760. 785. 1090. 1115. 1140. 1090. 1115. 1140. Flush Mounting Kits F860 F875 F890 Flush kit for P5 60" Ht. Flush kit for P5 75" Ht. Flush kit for P5 90" Ht. 140. 140. 140. — — — 140. 140. 140. Type 3R/12 WP860 WP875 WP890 Required P5 3R/12 60" P5 3R/12 75" P5 3R/12 90" with door over breaker handles. trims require amps per square inch bussing. Un-vented 10-64 Requires No 14.5 deep box. adder if ordered at time of order entry. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Type P5 Panelboards Dimensions Type 1 Box Box is symmetrical Box To Wall Mounting Holes Recommended Conduit Area 4.375 in. [ 111 ] 6.635 in. [ 169 ] 10.0 in. [ 254 ] 36.0 in. [ 914 ] Interior To Box Mounting Stubs 햲 60 in., 75 in., 90 in. [ 1524 ] [ 1905 ] [ 2286 ] 6.635 in. [ 169 ] 24 in. [ 610 ] 12.75 in. [ 324 4.375 in. [ 111 ] 30 in. [ 762 ] 햲 38 in. [ 965 ] 햲 Type 3R and 3R/12 Box 15.88 in. [ 403 ] .375 in. [ 10 ] 15.81 in. [ 402 ] Mounting Bracket 햲 60 in., 75 in., 90 in. [ 1524 ] [ 1905 ] [ 2286 ] .375 in. [ 10 ] 15.81 in. [ 402 ] 38 in. 햲 [ 965 ] .87 in. [ 22 ] 14.25 in. [ 362 ] 10 40 in. [ 1016 ] 햲 PANELBOARDS 42 in. [ 1067 ] 햲 Dimensions are interior of the box. Add 5/8" to width for absolute dimension. Add 1/8" to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-65 Panelboards Circuit Breaker / Column Type General Type C1 240 Volts AC Maximum 250 Ampere Mains 250 Ampere Maximum Branch UL Short Circuit Rating — 200,000 IR Maximum Branch Breaker Symmetrical Interrupting Rating Based on Underwriters’ Test Procedure Type C2 480Y/277 Volts AC Maximum 250 Ampere Mains 250 Ampere Maximum Branch UL Short Circuit Rating — 100,000 IR Maximum Meets 2002 NEC wire bending requirement, section 312–6. Panelboards Listed by Underwriter’s Laboratories, Inc., under “Panelboards” File #E2269. Meets Federal Specification W–C375B/Gen. Service 240 Volts Maximum. 1-Phase, 3-Wire, or 3-Phase, 4-Wire. Boxes C1 — 75⁄8" wide, 53⁄4" deep. C2 — 81⁄2" wide, 53⁄4" deep. Branch Breaker Side Gutters Type Circuit Breaker C1 BL, BLH, HBL, BQD 3.505 C2 BQD 3.5 Weight–Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is: *About 3 lbs. per inch of box height. Gauge Steel Boxes Type Width Height Gauge Steel C1 75⁄8" 48", 73", 85" #14 C2 81⁄2" 48", 73", 85" #14 C1 75⁄8" 48", 73", 85" #14 C2 81⁄2" 48", 73", 85" #14 Fronts Main Breaker Connectors Panelboards Fronts and Doors Standard panelboards are furnished with trim with a flush door lock. All are factory assembled for ease of installation. Fronts are fabricated from code gauge steel and finished ANSI-61. Main Breakers C1 BL, BLH and HBL frame breakers are mounted horizontally. All other frames are mounted vertically. Side Gutter (inches) Ampere Rating Connectors suitable for Cu or Al 100 (1) #14–1/0 AWG 125 (1) #4–1/0 AWG 225 (1) #6 AWG–300 kcmil 250 (1) #4 AWG–350 kcmil Al (1) #6 AWG–350 kcmil Cu Main Lug Connectors 125 (1) #6 AWG–350 kcmil 250 (1) #6 AWG–350 kcmil PANELBOARDS 10 Main Breakers C2 BQD frame breakers are mounted horizontally. All other frames are mounted vertically. For inches / millimeters conversion, see Application Data section. 햲 Connector ranges indicated do not apply to all main breaker types. Refer to molded case circuit breaker standard pressure wire connectors in the breaker section of this catalog for the wire ranges for a specific breaker frame. 10-66 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Series Connected Short Circuit Ratings The term “Series Connected Short Circuit Rating” refers to the application of series connected circuit breakers in a combination that allows some circuit breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by UL. The table below lists specific main and branch breaker series combinations that are marked on all C1 panels. All combinations shown have been tested for use in C1 panelboards and are UL Listed. Other combinations are available. See series rating information in the Circuit Breaker Section, pages 6-146 to 6-150. Ratings other than those shown below must be specified at the time of order entry. Panelboards Circuit Breaker / Column Type Selection Main Lugs Only C1 Maximum Panel Ampere Rating 125 250 240 Volts Maximum Maximum 1-Pole Circuits 18 30 42 18 30 42 Box Height (inches) 48 73 85 48 73 85 208Y/120V 3-Phase, 4-Wire Catalog Number C1C18ML125CTS C1C30ML125CTS C1C42ML125CTS C1C18ML250CTS C1C30ML250CTS C1C42ML250CTS List Price $ 1030.00 1250.00 1440.00 1100.00 1290.00 1520.00 120/240V 1-Phase, 3-Wire Catalog Number C1A18ML125CTS C1A30ML125CTS C1A42ML125CTS C1A18ML250CTS C1A30ML250CTS C1A42ML250CTS 48 73 85 48 73 85 48 73 85 48 73 85 C1C18BL100CTS C1C30BL100CTS C1C42BL100CTS C1C18E4125CTS C1C30E4125CTS C1C42E4125CTS C1C18QJ225CTS C1C30QJ225CTS C1C42QJ225CTS C1C18FX250CTS C1C30FX250CTS C1C42FX250CTS 1360.00 1570.00 1840.00 1910.00 2110.00 2390.00 2540.00 2750.00 2950.00 2950.00 3140.00 3350.00 C1A18BL100CTS C1A30BL100CTS C1A42BL100CTS C1A18E4125CTS C1A30E4125CTS C1A42E4125CTS C1A18QJ225CTS C1A30QJ225CTS C1A42QJ225CTS C1A18FX250CTS C1A30FX250CTS C1A42FX250CTS Main Circuit Breaker C1 240 Volts Maximum 18 30 42 18 30 42 18 30 42 18 30 42 100 125 225 250 List Price $ 1190.00 1170.00 1370.00 1010.00 1200.00 1420.00 Main Lugs Only C2 1250.00 1440.00 1660.00 1790.00 2020.00 2200.00 2150.00 2350.00 2550.00 2550.00 2760.00 2960.00 480Y/277 Volts Maximum Maximum Panel Ampere Rating 125 250 Maximum 1-Pole Circuits 18 30 42 18 30 42 Box Height (inches) 48 73 85 48 73 85 480Y/277V 3-Phase, 4-Wire Catalog Number C2E18ML125CTS C2E30ML125CTS C2E42ML125CTS C2E18ML250CTS C2E30ML250CTS C2E42ML250CTS 18 30 42 18 30 42 18 30 42 18 30 42 48 73 85 48 73 85 48 73 85 48 73 85 C2E18BD100CTS C2E30BD100CTS C2E42BD100CTS C2E18E4125CTS C2E30E4125CTS C2E42E4125CTS C2E18FX225CTS C2E30FX225CTS C2E42FX225CTS C2E18FX250CTS C2E30FX250CTS C2E42FX250CTS Main Circuit Breaker C2 100 125 225 250 List Price $ 1030.00 1260.00 1440.00 1100.00 1290.00 1520.00 480Y/277 Volts Maximum 1710.00 1930.00 2190.00 1910.00 2110.00 2390.00 2710.00 2980.00 3240.00 2950.00 3140.00 3350.00 Alternate Main Breaker Selection C1 Ampere Rating 100 125 225 225 250 Breaker Type BL BLH HBL ED4 HED4 QJ2 QJH2 QJ2-H FXD6 HFD6 FXD6 HFD6 Maximum Interrupting Rating (KA) 10 22 65 65 100 10 22 42 65 100 65 100 Catalog Number BL LH HL E4 H4 QJ QH Q2 FX HF FX HF List Price $ STD 65. 405. STD 540. STD 100. 160. 140. 1760. STD 1900. Available Trip Values 50, 60, 70, 80, 90, 100 50, 60, 70, 80, 90, 100 50, 60, 70, 80, 90, 100 50, 60, 70, 80, 90, 100, 110, 125 50, 60, 70, 80, 90, 100, 110, 125 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 250 250 10 PANELBOARDS For inches / millimeters conversion, see Application Data section. Discount Schedule PBSB BL, BLH, HBL and BQD are horizontally mounted. All others vertically mounted. Interchangeable trip breakers such as FD6 and HFD6 cannot be back fed. Must be top feed only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-67 Panelboards Circuit Breaker / Column Type Selection Branch Breaker Selection C1 Breaker Type BL (120V) BL (HID) BLF (GFCI) BLE (EQGFI) BGL (SWN) BLR (240V) BLH (120V) BLHF (GFCI) HBL BQD Available Ampere Rating 15, 20, 30, 70 70, 80, 90, 15, 20, 30 15, 20, 30 40, 50, 60 15, 20, 30 15, 20, 30 15, 20, 30, 70, 80, 90, 15, 20, 30, 70 70, 80, 90, 15, 20, 30 40, 50, 60 15, 20, 30, 60, 70, 80, 15, 20, 30, 70, 80, 90, 1-Pole 25. 35. — 55. 140. — 220. — — — 35. 75. — 155. — 65. — 85. 200. 2-Pole 45. 85. 140. 80. 240. 250. 330. 100. 105. 185. 85. 130. 200. 270. 291. 150. 400. 270. 400. 3-Pole 140. 190. 210. — — — — 130. — — 220. 300. 310. — — 290. 480. 290. 480. Provisions for Future $ — — — — — — — — — — — — — — — — — — — —– —– —– —– —– —– —– —– —– 420. 750. 690. 1270. 420. 930. 1080. 1220. 2440. 540. 910. 910. 1450. 880. 1140. 1410. 1540. 3010. 100. 100. 100. 100. 150. 150. 150. 200. 200. List Price Installed $ 40, 50, 60 100 40, 50, 60 100 40, 50, 60 100 40, 50 90, 100 40, 50, 60 100 Maximum Interrupting Rating (kA) 120V — — — — 10 10 10 10 — — — — — — — — — — — 120/240V 10 10 10 — — — — — — — 22 22 22 22 22 65 65 — — 240V — — — — — — — — 10 10 — — — — — 65 65 65 65 — — — — — — — — — — — — — — — — — — 65 65 65 100 10 22 42 65 100 Subfeed Breakers — Limit One Per Panel C1 ED4 HED4 QJ2 QJH2 QJ2-H FXD6 HFD6 15, 20, 30, 110, 125 15, 20, 30, 110, 125 60, 70, 80, 60, 70, 80, 60, 70, 80, 70, 80, 90, 70, 80, 90, 40, 50, 60, 70, 80, 90, 100 40, 50, 60, 70, 80, 90, 100 90, 100, 110, 125, 150, 175, 200, 225 90, 100, 110, 125, 150, 175, 200, 225 90, 100, 110, 125, 150, 175, 200, 225 100, 110, 125, 150, 175, 200, 225, 250 100, 110, 125, 150, 175, 200, 225, 250 Alternate Main Breaker Selection C2 Ampere Rating Breaker Type BQD ED4 ED6 HED4 HHED6 ED4 ED6 HED4 HHED6 FXD6 HFD6 FXD6 HFD6 100 125 225 250 Catalog Number BD E4 E6 H4 H6 E4 E6 H4 H6 FX HF FX HF IR 14 18 25 42 65 18 25 42 65 35 65 35 65 List Price $ STD 55. 65. 290. 390. STD 25. 290. 390. STD 1760. STD 1760. Available Trip Values 50, 60, 70, 80, 90, 100 50, 60, 70, 80, 90, 100 50, 60, 70, 80, 90, 100 50, 60, 70, 80, 90, 100 50, 60, 70, 80, 90, 100 110, 125 110, 125 110, 125 110, 125 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 250 250 Branch Circuit Breakers C2 Breaker Type BQD Available Ampere Rating 15, 20, 30, 40, 50, 60 70, 80, 90, 100 1-Pole 85. 200. 2-Pole 270. 400. 3-Pole 290. 480. Provisions for Future $ —– —– —– —– —– —– —– —– —– —– 420. 750. 530. 1090. 690. 1270. 1220. 2440. 540. 910. 860. 1090. 910. 1450. 1540. 3010. 100. 100. 100. 100. 100. 100. 200. 200. List Price Installed $ Maximum Interrupting Rating (kA) 277V 14 14 480/277V 14 14 480V — — — — — — — — — — 18 18 — — — — — — 18 18 25 25 42 42 35 65 Subfeed Breakers — Limit One Per Panel C2 ED4 PANELBOARDS 10 ED6 HED4 FXD6 HFD6 15, 20, 30, 110, 125 15, 20, 30, 110, 125 15, 20, 30, 110, 125 70, 80, 90, 70, 80, 90, 40, 50, 60, 70, 80, 90, 100 40, 50, 60, 70, 80, 90, 100 40, 50, 60, 70, 80, 90, 100 100, 110, 125, 150, 175, 200, 225, 250 100, 110, 125, 150, 175, 200, 225, 250 No increase in box height. Space is already built into C1 panel. BL, BLH, HBL and BQD are horizontally mounted. All others vertically mounted. 10-68 Interchangeable trip breakers such as FD6 and HFD6 cannot be back fed. Must be top feed only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Sentron® Panelboards Circuit Breaker / Column Type, Modifications and Additions Selection Type C1/C2 When required, special constructions or additions to standard panelboards may be specified for factory-assembled column panelboards. Box Modifications Description List Price $ Gasketed Metal Card Holder Welded Metal Card Holder Nameplate Al Ground Bar Cu Ground Bar Insulated Al Ground Bar Insulated Cu Ground Bar 670. 65. 125. 55. STD 40. 40. 75. Interior Modifications Box Sizing Chart Certain modifications such as subfeed breakers and feed-thru lugs require additional unit space. Use this chart to determine proper enclosure size. Panel Configuration Box Height (inches) All MLO 18 Circuit All MLO 30 Circuit All MLO 42 Circuit 48 73 85 All MLO 18 Circuit with feed-thru lugs All MLO 30 Circuit with feed-thru lugs All MLO 42 Circuit with feed-thru lugs 73 85 85 All MLO 18 Circuit with subfeed breaker All MLO 30 Circuit with subfeed breaker 73 85 Description List Price $ All Main Breaker 18 Circuit All Main Breaker 30 Circuit All Main Breaker 42 Circuit 48 73 85 Feed-Thru Lugs Cu Neutral Lugs Cu main Lugs 125A Cu main Lugs 250A 180. 110. 115. 190. All Main Breaker 18 Circuit with feed-thru lugs All Main Breaker 30 Circuit with feed-thru lugs All Main Breaker 42 Circuit with feed-thru lugs 73 85 85 All Main Breaker 18 Circuit with subfeed breaker 73 All Main Breaker 30 Circuit with subfeed breaker 85 Column Extension Available in various standard lengths, extensions are 51⁄4 inches deep and 7 inches wide. Height (inches) Catalog Number List Price $ 14 20 26 32 38 41 44 53 56 62 65 68 74 80 86 LXX-14 LXX-20 LXX-26 LXX-32 LXX-38 LXX-41 LXX-44 LXX-53 LXX-56 LXX-62 LXX-65 LXX-68 LXX-74 LXX-80 LXX-86 150.00 160.00 180.00 180.00 210.00 210.00 235.00 255.00 275.00 285.00 305.00 305.00 330.00 360.00 380.00 Pull Boxes Two styles of pull boxes are available, top and front mounted. When the panel and its extensions are mounted in a structural WF beam a front mounted pull box is required. When the panels are surface mounted, a top mounted pull box may be used. Provisions are made so that the neutral bar may be mounted in the pull box when required. (Front mounted pull box dimensions are 14" H. X 20" W.) Description Catalog Number List Price $ Top Mount Front Mount LXXP-T LXX50-F 180.00 445.00 10 PANELBOARDS For inches / millimeters conversion, see Application Data section. Discount Schedule PBSB Includes 50" extension. Price additional extensions from above. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-69 Sentron Panelboards ® Telephone and Equipment Cabinets Selection/Dimensions Telephone and Equipment Cabinets: Conform to requirements of Underwriters’ Laboratories, Inc., for all cabinets and boxes bearing their label. Surface and Flush enclosures: box and front constructed of code-gauge steel, box galvanized and front only finished with light gray, ANSI-61. Boxes: Standard construction has blank end walls, without knockouts. Fronts: Siemens Fas Latch fronts feature concealed hinges and fastening screws. Match P1 and P2 Panels in appearance. Two locks supplied on doors more than 51 inches high. Cabinets Dimensions (inches) Height Width Depth Catalog Number List Price $ Without Backboard List Price $ With Backboard With FAS Latch Front 23 20 5.75 TC 햲 23B 300. 350. 26 20 5.75 TC 햲 26B 320. 370. 29 20 5.75 TC 햲 29B 340. 390. 32 20 5.75 TC 햲 32B 360. 410. 35 20 5.75 TC 햲 35B 380. 430. 38 20 5.75 TC 햲 38B 400. 450. 41 20 5.75 TC 햲 41B 420. 470. 44 20 5.75 TC 햲 44B 440. 490. 47 20 5.75 TC 햲 47B 460. 510. 50 20 5.75 TC 햲 50B 480. 530. 53 20 5.75 TC 햲 53B 500. 550. 56 20 5.75 TC 햲 56B 520. 570. 59 20 5.75 TC 햲 59B 540. 590. 62 20 5.75 TC 햲 62B 560. 610. 65 20 5.75 TC 햲 65B 580. 630. 23 24 5.75 TC W 햲 23B 420. 470. 29 24 5.75 TC W 햲 29B 460. 510. 35 24 5.75 TC W 햲 35B 500. 550. 38 24 5.75 TC W 햲 38B 520. 570. 41 24 5.75 TC W 햲 41B 540. 590. 44 24 5.75 TC W 햲 44B 560. 610. 53 24 5.75 TC W 햲 53B 620. 670. 59 24 5.75 TC W 햲 59B 640. 690. PANELBOARDS 10 Dimensions For inches / millimeters conversion, see Application Data section. 10-70 햲 Add S for Surface, F for Flush. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Sentron Panelboards ® Enclosure Modifications Dimensions H 23 26 29 32 35 38 41 44 47 50 53 56 59 62 65 68 71 74 77 Customer Relay Cabinets Catalog D Number 5.75 RC(1)23B 5.75 RC(1)26B 5.75 RC(1)29B 5.75 RC(1)32B 5.75 RC(1)35B 5.75 RC(1)38B 5.75 RC(1)41B 5.75 RC(1)44B 5.75 RC(1)47B 5.75 RC(1)50B 5.75 RC(1)53B 5.75 RC(1)56B 5.75 RC(1)59B 5.75 RC(1)62B 5.75 RC(1)65B 5.75 RC(1)68B 5.75 RC(1)71B 5.75 RC(1)74B 5.75 RC(1)77B W 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Selection List Price $ 355.00 378.00 386.00 394.00 401.00 562.00 594.00 594.00 604.00 625.00 636.00 647.00 678.00 700.00 753.00 784.00 827.00 859.00 912.00 Note: Replace (1) with ”S” for surface applications and ”F” for flush applications. Dimensions H 23 26 29 32 35 38 41 44 47 50 53 56 59 62 65 68 71 74 77 W 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 Customer Relay Cabinets Catalog D Number 5.75 RCW(1)23B 5.75 RCW(1)26B 5.75 RCW(1)29B 5.75 RCW(1)32B 5.75 RCW(1)35B 5.75 RCW(1)38B 5.75 RCW(1)41B 5.75 RCW(1)44B 5.75 RCW(1)47B 5.75 RCW(1)50B 5.75 RCW(1)53B 5.75 RCW(1)56B 5.75 RCW(1)59B 5.75 RCW(1)62B 5.75 RCW(1)65B 5.75 RCW(1)68B 5.75 RCW(1)71B 5.75 RCW(1)74B 5.75 RCW(1)77B List Price $ 372.00 396.00 402.00 411.00 419.00 583.00 615.00 615.00 636.00 647.00 657.00 678.00 710.00 721.00 795.00 816.00 869.00 890.00 943.00 List Price includes Fas latch trim and steel mounting pan. If 2 or more cabinets are to be stacked, specify on order (no extra charge for connecting hardware). Additional Enclosures Modifications Description List Price $ Strip Heaters 910. Humidstat control 1600. Thermostat control 1600. Ampere Rating 20 30 60 75 100 150 200 225 260 300 400 600 800 1000 1200 ASCO #920 Mechanically held List Price $ 2-Pole 3-Pole — — 2680. 3075. 3360. 4315. 3360. 4315. 3795. 4940. 5215. 6615. 5970. 7430. 6455. 8090. — — — — — — — — — — — — — — ASCO #911 — 3-poles Mechanically held remote control switch suitable for all classes of loads (Total system loads). Voltage rated to 480V AC, UL listed. List Price $ — — — — 7015. 9475. — — 19400. 26935. 44520. 44520. 46270. 60270. 65530. Siemens LEN Electrically Held List Price $ 2-Pole — 1270. 1580. — 2055. 3360. 3360. — — — — — — — — 3-Pole — 1495. 1920. — 2415. 4015. 4015. — — — — — — — — Application (See individual panel sections for application information) Control Power Transformer Remote Control Switch Modification VA 50 75 150 250 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-71 PANELBOARDS Discount Schedule PBSB 490. 850. Size 0,1 2 3 4 List Price Adder $ 245. 350. 510. 625. 10 Description Separate Door in Dead Front Over Switch (P2 as main only) Auxiliary Contacts (Mounted Not Wired) Ea. 2-Wire Control (add 6" to panel height.) List Price Adder $ 410. Panelboards Modifications and Additions Selection End Walls Only for 5.75 in. Deep Box End Walls Only for 7.75 in. Deep Box With knockouts Blank $30. List Each 20. List Each With knockouts Blank Miscellaneous $40. List Each 30. List Each Description Conduit Hubs — Up to 1 1/2 in. Each 2 in. to 2 1/2 in. Each 3 in. Each Standard Enclosures Made From Special Materials - Type P1, P2, P3 Aluminum, Stainless Steel, and Chrome Plated Enclosures. Price standard panelboard and add from the following table. Material Panel Over 20 in. 60. 60. 90. 110. 90. 110. Increased Gauge Steel - 10 gauge Maximum Box and Front Box or Front Only 265. 185. List Price $ Up to 20 in. W Over 20 in. W 1185. 1540. 1045. 1845. 1920. 3440. 1540. 2570. 1845. 3045. 2600. 5000. Front And Door Modifications 1450. Vault Handle Cutout in Trim햳 Two Panels with Common Trim햴 265. 185. Painted Finish Aluminum Box Front Box Front Alumite Mill Finish Set-up Charge Net Box Only Alternate Color Trim Template Must Accompany Order General Purpose Grade (Brush Front) Box Front Chrome Plate Polished Finish Front Only 1185. 90. 480. 250. 340. 햲 Panels Addition Width Width Per 2" 85. 30. 30. Special Drillings Stainless Steel 햳 햴 Lighting Panel 205 Distribution Panels 350 Consult factory for dimension limitations. Addition Depth Depth Per 2" List Price $ Panel Width 20 in. Lighting Panel 150 Devices Mounted On Trim-Includes Device, Mounting (Wired or Unwired) Toggle Switch-SPST or 3-way; 15A, 277 V Maximum First Switch Each Additional Pilot Light-General Purpose, Neon or Incandescent First Light Each Additional Pushbutton First Device Each Additional 350. 210. 350. 210. 350. 210. PANELBOARDS 10 Consult factory for dimension limitations. Distribution Panels 250 having doors over 48 in. high, 2 locks are standard. Voids UL label. Lighting panels only. Field must supply dimensional information and panel orientation. 10-72 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PBSB Panelboards Circuit Breaker Accessories and Modifications Blank Plates—Vacu-Break For use with VB-23, VB-30, VB-32 and Uni-Power Switchboards 12 in. Units—23 in. Wide Enclosures Only 17 in. Units—30 in. and 32 in. Wide Enclosures Catalog Number List Price $ Catalog Number List Price $ 2 1/2 5 VB2F025 VB2F050 121.00 139.00 VB7F025 VB7F050 163.00 163.00 7 1/2 10 VB2F075 VB2F100 139.00 163.00 VB7F075 VB2F100 181.00 163.00 Unit Height (in.) Conduit Enclosing Shield (Panel Skirts) Sheet metal to cover conduits above or below a standard panelboard box. Skirt Length 8, 9, 11, 12 14, 17, 18, 23, 26, 27, 28, 29, 32, 33, 34, 35, 37, 38, 39, 40, 8, 9, 11, 12 14, 17, 18, 23, 26, 27, 28, 29, 32, 33, 34, 35, 37, 38, 39, 40, 25 30, 31, 36 41, 42, 43, 44 25 30, 31, 36 41, 42, 43, 44 Width List Price $ 4 Side Adder $ 20.00 20.00 125. 225. 110. 110. 20.00 320. 110. 20.00 24.00 24.00 405. 200. 320. 110. 145. 145. 24.00 435. 145. 24.00 530. 145. Selection Molded Case Switches (Non-Automatic Circuit Interrupters) When Molded case switches are substituted for thermal breakers deduct from the installed thermal breaker price: Ampere Rating Breaker Frame 100 ED2 ED4 ED6 225 QJ2 60. 35. 250 FXD6 200. 170. 400 JXD2 JXD6 405. 455. 325. 370. 3-Pole Number of Poles 2-Pole 95. 95. 95. 75. 80. 85. 600 LXD6 760. 590. 800 MD6 1790. 1350. 1200 ND6 3650. NA Panel Skirts Standard Length 3 Sides Open Back 4 Sides Screw Front 8, 9, 10,11, 12, 14, 17, 18, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44 10 PANELBOARDS Discount Schedule PBSB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-73 PANELBOARDS 10 Notes 10-74 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 11SPEEDFAX TM 2007-2008 Lighting Controls 11 Contents 11-2 LCP300EZ Catalog Numbering System & Accessories 11-3 LCP300EZ Accessory Options LCP300EZ Device Descriptions LCP3000EZ LAN Software (ComBridge Studio) LCP3000EZ Wiring Diagrams LCP3000EZ Other Applications Benefits of Lighting Control Systems The benefits of lighting control systems include enhanced comfort, productivity, security, environmental aesthetics and of course, energy savings. In terms of energy savings, many lighting control systems can easily pay for themselves in less than two years. Siemens has developed a new lighting control system which is simple in both design and installation. It efficiently covers a complex range of lighting schemes with a minimal investment of time and money. The Siemens LCP3000EZ Lighting Control Systems has been designed to make lighting control genuinely accessible for any building, whether the need is a single ON-OFF panel, or a complicated fully networked system of control panels sequencing on-off schemes across a hundred floors. In short, lighting control is something you can do quickly and affordably. For production details and pricing, please contact your nearest local Siemens sales office or contact the Siemens Call Center at 1-800-427-2256 for technical information. Code Requirements ANSI/ASHRAE/IESNA require positive lighting control beyond the historical light switch and circuit breaker disconnect panel. The code states: Interior lighting in non-residential buildings larger than 5000 square feet and not in operation 24 hours a day shall be controlled with an automatic control device to shut off building lighting in all spaces. This automatic control device shall function on a scheduled basis or an occupancy sensor or a signal from an other control or alarm system. The LCP3000EZ is California Title 24 Certified. Residential Commercial Industrial 11-4 11-5 – 11-6 11-7 – 11-8 11-9 – 11-10 11-11 LIGHTING CONTROLS LCP3000EZ Panels Lighting Controls LIGHTING CONTROLS 11 LCP3000EZ Panels System Features The Siemens LCP3000EZ is fully assembled and delivered with all specified relays, digital inputs, power supply and RS232 interface installed in the enclosure. Wall mount the enclosure. Connect the 120V AC power supply. connect the loads to the relays. Connect the inputs. Then with a PDA with serial port support (RS232) (running Palm OS 3.5 or higher), configure which inputs control which output/s (relay/s) and the system is ready to go. The configuration software also can be run on a PC using Palm Emulator software. The configuration software and the Palm Emulator are provided with every order at no charge. If your system has more than one panel, simply interconnect the panels with an 18 AWG solid copper twisted pair. The Siemens LCP3000EZ lighting control system comes with an System Specifications ▪ NEMA 1, surface mount, optional key lock and flush mount kit ▪ Enclosures are always 20" wide and 53⁄4" deep; height depends on number of outputs: - 24" high for up to 16 outputs - 32" high for up to 32 outputs - 40" high for up to 48 output relays ▪ Load relays: - Mechanically held - Visual position indicator - Have manual override - Built in timer which can be set in 30 minute intervals up to 6 hours - Eight relays per module - Can be programmed as groups to control two or three pole loads 11-2 General abundance of standard operating features and the intelligence to meet virtually any lighting control application. Each panel is equipped with an RS232 interface for easy configuration of inputs and outputs. Any panel in the network can be configured from any other panel in the same network. Other options include Ethernet interface, PC software, two different time clocks (4 and 16 control points, which provide the ability to set 324 or 500 schedules respectively), motion sensors, dual sensors for light and temperature and more. These options enable you to have a lighting control system that can meet even the most demanding applications. Each individual device holds its own operating program in non-volatile memory. There is no central or master controller. This feature prevents entire system shut down, which could happen on systems with a central logic board. Networking Up to 10 panels can be networked together without the need for any additional cards or devices. With optional Web access devices and ComBridge Studio Software, the user can network up to 500 panels. The LCP3000EZ interfaces with any Building Automation System using OPC. Web Access Software The optional Web access software allows the user access any device in the LCP3000EZ system. This allows control of - Are rated 20 Amp, 277 Volt (480V “Y” with ground three phase loads) ▪ All panel size accept a maximum of 32 digital (switch) inputs: - Rated 24V AC/DC - Can be configured to accept maintained, or momentary inputs - Four inputs per module ▪ 4 control channels time clock allows 324 schedules ▪ 16 control channels time clock allows 500 schedules. Four channels have astronomical clock feature - Both time clocks have 10 years battery back up - Automatic day light savings time adjustment Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog any relay from a PC. Password protection allows partial control to individual users. For example, the employee can turn ON or OFF the office lights from any PC. Enclosure The LCP3000EZ is enclosed in a NEMA 1, UL listed enclosure with hinged door and hinged dead fronts. There are two dead fronts, one for the low voltage (24V) section and one for the line voltage load relays. There is a barrier between the two sections. Technical Literature You are able to review and download a copy of the LCP3000EZ Lighting Control Selection and Application Guide at http://www.sea.siemens.com/power/pr oduct/pdprodlc_3000ez.html. A printed version of the Selection and Application Guide, No. LCSA-03000-0604, or the Technical Data Sheet, No. LCSS-010020304, can be requested through the Siemens Call Center at 1-800-427-2256. ▪ ▪ ▪ ▪ - Time of day (TOD) schedules - Warn Off - 5 minutes RS-232 interface in every panel Network up to 10 panels twisted pair wire, without additional cards Network up to 500 panels with optional Web access devices and ComBridge Studio Software Ambient Conditions: - Ambient operating temperature: 23˚F - 113˚F (-5... +45˚C) - Ambient temperature (non-op): -13˚F - 158˚F (-25... +70˚C) - Relative Humidity (non-condensing): 5% to 93% Lighting Controls LCP3000EZ Accessories LCP3000EZ Catalog Numbering System -Z LIGHTING CONTROLS Enclosure Height 3 = 24" (up to 16 relays = 2 output (relay) modules) 4 = 32" (up to 32 relays = 4 output (relay) modules) 5 = 40" (up to 48 relays = 6 output (relay) modules) Panel Designation A, B, C, D, E, F, G, H, J or K Number of Input Modules Select 0, 8, 16, 24 or 32 inputs. Divide the number of inputs by 8 to get the number to enter at this location. i.e. 24 inputs / 8 = 3. To format the LCP3000EZ catalog number proceed as follows: 1. Enclosure Height: Determine the number of relays and provisions for future relay additions your installation requires. Round the number up to the nearest multiple of 8 (relays come in blocks of 8 relays). - 8 to 16 outputs (relays) enclosure height is 24". Enter 3 in the Enclosure Height field - 24 to 32 outputs (relays) enclosure height is 32". Enter 4 in the Enclosure Height field - 40 to 48 outputs (relays) enclosure height is 40". Enter 5 in the Enclosure Height field 2. Panel designation: First panel is A, second panel is B, third panel is C, etc. Last panel is K. There is no Panel I. 3. Number of input Modules: Determine the number of inputs your system requires and round the number up to the nearest multiple of 8 (input modules are packaged as 2 blocks of 4; therefore, they are supplied in groups of 8). Divide the number of inputs by 8 to determine the number of input modules: - 8 inputs: enter 1 in the Number of Input Modules field - 16 inputs: enter 2 in the Number of Input Modules field - 24 inputs: enter 3 in the Number of Input Modules field - 32 inputs: enter 4 in the Number of Input Modules field 4. Number of output (relay) modules: Determine the number of relays, and provisions for future relay additions your installation requires; then round the number up to the nearest 8 (relays come in blocks of 8 relays). Divide the number of relays by 8 to determine the number of output (relay) modules: 11 Catalog No. 5WG1 70 -8X Number of Output Modules 1 to 6 (8 outputs per module; i.e. 48 outputs / 8 outputs per module = 6 output modules). - 8 relays: enter 1 for Number of Output (relay) Modules field - 16 relays: enter 2 in the Number Output (relay) Modules field - 24 relays: enter 3 in the Number Output (relay) Modules field - 32 relays: enter 4 in the Number Output (relay) Modules field - 40 relays: enter 5 in the Number Output (relay) Modules field - 48 relays: enter 6 in the Number Output (relay) Modules field Enclosure Options Blank = None 1 = Flush Mounting Kit 2 = Key Lock 3 = Key Lock and Flush Mounting Kit 32/8 = 4. Enter 4 in the Number of Output (relay) Modules field. of of of of of 5. Enclosure options: Determine if key lock, flush mounting kit of both are required. - No option required: leave the Enclosure Options field blank - Flush mount kit: enter 1 in the Enclosure Options field - Key lock: enter 2 in the Enclosure Options field - Key lock and flush mount kit: enter 3 in the Enclosure Options field Example: A system needs two panels: The first panel requires 20 inputs and 30 outputs (relays). The second panel requires 31 inputs and 44 outputs (relays). Key lock is required in both panels. First Panel: 1. Enclosure height: Number of outputs (relays) = 30, round up to the nearest multiple of 8 which is 32. 32/8 = 4. Enter 4 in the Enclosure Height field. 2. Panel designation: This is the first panel. Enter A in the Panel Designation field. 3. Number of input modules: Number of inputs = 20, round up to the nearest multiple of 8 which is 24. 24/8 = 3. Enter 3 in the Number of Input Modules field 4. Number of output (relay) modules: Number of relays = 30 round up to the nearest multiple of 8 which is 32. Second Panel: 5. Enclosure height: Number of outputs (relays) = 44, round up to the nearest multiple of 8 which is 48. 48/8 = 6. Enter 5 in the Enclosure Height field. 6. Panel designation: This is the second panel. Enter B in the Panel Designation field. 7. Number of input modules: Number of inputs = 31, round up to the nearest multiple of 8 which is 32. 32/8 = 4. Enter 4 in the Number of Input Modules field. 8. Number of output (relay) modules: Number of relays = 42 round up to the nearest multiple of 8 which is 48. 48/8 = 6. Enter 6 in the Number of Output (relay) Modules field. Applicable to all panels: 9. Enclosure options: Key lock required. Enter 2 in the Enclosure Options field. Finalized catalog numbers: First panel is: 5WG1 704-8XA34-Z2 Second panel is: 5WG1 705-8XB46-Z2 External options After you have finished with the LCP3000EZ catalog number, select any external options for the project. i.e.: - Motion sensors (two SIEMENS motion sensors are supported per panel). Third party motion sensors with dry contacts can be used; This type is used in conjunction with the Input Modules - Outdoor light sensor (one is supported by each network of 10 panels - Override or key switch (you may select this option, although the binary inputs can also be used for this purpose - Web Access software (ComBridge Studio) - OPC interface - E-mail services - Data Base services Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 11-3 Lighting Controls LCP3000EZ Accessories LIGHTING CONTROLS 11 Options (not included in panel catalog number) 5WG1 372-5EY01-Z-A201 4 control channels time clock 5WG1 373-5EY01-Z-A202 16 control channels time clock 5WG1 255-2AB11 Motion sensor 5WG1 114-2AB02-Z-A221 Wall mounted bus coupler for motion sensor(s). Panel A* 5WG1 114-2AB02-Z-A231 Wall mounted bus coupler for motion sensor(s). Panel A* 5WG1 114-2AB02-Z-B222 Wall mounted bus coupler for motion sensor(s). Panel B* 5WG1 114-2AB02-Z-B232 Wall mounted bus coupler for motion sensor(s). Panel B* 5WG1 114-2AB02-Z-C223 Wall mounted bus coupler for motion sensor(s). Panel C* 5WG1 114-2AB02-Z-C233 Wall mounted bus coupler for motion sensor(s). Panel C* 5WG1 114-2AB02-Z-D224 Wall mounted bus coupler for motion sensor(s). Panel D* 5WG1 114-2AB02-Z-D234 Wall mounted bus coupler for motion sensor(s). Panel D* 5WG1 114-2AB02-Z-E225 Wall mounted bus coupler for motion sensor(s). Panel E* 5WG1 114-2AB02-Z-E235 Wall mounted bus coupler for motion sensor(s). Panel E* 5WG1 114-2AB02-Z-F226 Wall mounted bus coupler for motion sensor(s). Panel F* 5WG1 114-2AB02-Z-F236 Wall mounted bus coupler for motion sensor(s). Panel F* 5WG1 114-2AB02-Z-G227 Wall mounted bus coupler for motion sensor(s). Panel G* 5WG1 114-2AB02-Z-G237 Wall mounted bus coupler for motion sensor(s). Panel G* 5WG1 114-2AB02-Z-H228 Wall mounted bus coupler for motion sensor(s). Panel H* 5WG1 114-2AB02-Z-H238 Wall mounted bus coupler for motion sensor(s). Panel H* 5WG1 114-2AB02-Z-J229 Wall mounted bus coupler for motion sensor(s). Panel J* 5WG1 114-2AB02-Z-J239 Wall mounted bus coupler for motion sensor(s). Panel J* 5WG1 114-2AB02-Z-K230 Wall mounted bus coupler for motion sensor(s). Panel K* 5WG1 114-2AB02-Z-K240 Wall mounted bus coupler for motion sensor(s). Panel K* 5WG1 588-2CB11-Z-A211 Touch Panel, Panel A 5WG1 588-2CB11-Z-B212 Touch Panel, Panel B 5WG1 588-2CB11-Z-C213 Touch Panel, Panel C 5WG1 588-2CB11-Z-D214 Touch Panel, Panel D 5WG1 588-2CB11-Z-E215 Touch Panel, Panel E 5WG1 588-2CB11-Z-F216 Touch Panel, Panel F 5WG1 588-2CB11-Z-G217 Touch Panel, Panel G 5WG1 588-2CB11-Z-H218 Touch Panel, Panel H 5WG1 588-2CB11-Z-J219 Touch Panel, Panel J 5WG1 588-2CB11-Z-K220 Touch Panel, Panel K 5WG1 254-3EY01-Z-A203 Outdoor ambient light level sensor 5WG1 220-2CB02-Z-A204 Key switch 63101-32-01 Software for LAN connection (for monitoring and control) 63101-32-10 5 license extension for LAN software 63101-32-06 OPC services for connection with BAS, LAN software required 63101-32-01 LAN software e-mail services 63101-32-04 LAN software database services 63101-32-08 LAN software Visual Editor * Each panel supports 2 SIEMENS motion sensors. Catalog number corresponds to bus coupling 1 and bus coupling 2 for each panel. The actual motion sensing device plugs into the bus coupling unit. Notes about components catalog number: – First 12 characters are the “out of the box” component catalog number (i.e. 5WG1 588 2CB11). – Z is a position holder in the catalog number sequence. – Last four characters are for a component’s specific location in the system (for example K220; where K indicates that the device belongs to panel K and 220 is the device’s unique address). 11-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5WG1 376-5EY01-Z-A201 4 Control channels 5WG1 254-3EY01-Z-A203 Outdoor ambient light sensor 5WG1 148-1AB21-Z-A251 IP Interface Lighting Controls Accessories Selection Description of devices Input Device (5WG1 2611CB01): Block of 4 digital inputs. It can take inputs from a set of dry contacts (maintained or momentary). Inputs requires 24 volt supplied by the power supply. Power Supply (5WG1 1231CB01): Input 120 V, 50/60 HZ. One per panel. It supplies voltage for communications and for the inputs. Choke (5WG1 120-1AB01): It is mounted next to the power supply. The choke prevents the power-supply 5WG1 123-1CB01 from short-circuiting the data on the bus line. It picks up the power from the two outer printed conductors and feeds it via inductors to the two inner printed conductors. Four Control Channels Time Clock (5WG1 372-5EY01): It has four control channels; each channel can be seen by the system as an input. This device can be programmed with up to 322 different schedules, automatic day light saving time and 10 years battery back up. Sixteen Control Channels Time Clock (5WG1 373-5EY01): It has 16 control channel. Each channel can be seen by the system as an input. This device can be programmed with up to 500 different schedules, automatic day light saving time and 10 years battery back up. The first four control channels can be programmed as astronomical time clock. This feature allows to control the outside lights based on date and geographical location, rather than with an outdoor light level sensor. RS232 Interface (5WG1 1481AB04: It allows the user to configure the panel on site via a DB9 serial cable. Configuration is done with the software supplied free of charge with every order. IP Interface (5WG1 148-1AB21): It allows connection to the user’s LAN for control and monitoring of the system. Optional ComBridge Studio software is required for LAN connectivity. It can be configured for fixed IP address and also for DHCP. Outdoor Ambient Light Sensor (5WG1 P254-3EY01): Used to control outdoor lights such as parking lot, signs, drive through window. Three light level thresholds (100 Fc, 50 Fc and 20 Fc) are pre-programmed into the device. This is also a temperature sensor. Outside temperature can be read when the optional ComBridge Studio LAN software is used. Motion Sensor (5WG1 2552AB11): Detects motion to command light to turn ON. Each motion sensor require bus coupling unit 5WG1 114-2CB02. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 11-5 LIGHTING CONTROLS Output (relay) Device (5WG1 512-1CB01): Block of 8 277 V, 20 amp, relays with timers, visual indication and manual override capability. 11 All devices described here are interconnected via 18 AWG solid copper twisted pair or via a communication bus on the DIN rails incorporated into the panels. Lighting Controls LIGHTING CONTROLS 11 Accessories Selection Key Switch (5WG1 220-2CB02): It is a block of 4 digital inputs. It can take inputs from a set of dry contacts (maintained or momentary). It requires no voltage from the power supply. One UP220 device is supported by each set of 10 panels. This device is intended to be used for after hours override purposes (i.e. cleaning crews). Touch panel (5WG1 588-2CB11): It allows remote control of the lights. It also provides relay status, indication of outside light level and temperature. Each panel in the system can have a dedicated touch panel. 11-6 LAN software (ComBridge Studio): It allows connectivity to the user’s LAN for control and monitoring of the lighting control system. It has options for the following applications: ▪ Additional licenses to allow more than one person to control the lights (access is password protected with levels of access authority) ▪ OPC interface: For communications with building automation systems (BAS) ▪ E-mail services: can be programmed to send e-mail when a pre-selected event occurs ▪ Database Services: Stores pre-selected events on a database for further viewing and analysis ▪ Visual editor: Allows a graphical interface with the lighting control system Replacement parts To order replacement parts simply refer to the number on a device label (for devices installed in the enclosure, this number label is also on the inner door. This number starts with the panel letter designation followed by a number (i.e. A-101). From this number, SIEMENS knows exactly what you need. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Lighting Controls Web Visualization with ComBridge Studio e-Mail Service WebAccess Engine Database Service InfoPoint Configurator The OPC service links EIB elements with OPC client systems. Configuration Manager Automation Services execute automation functions directly from the ComBridge Studio Server PC: schedule jobs, e-mails and database entries for the purpose of data analysis and reporting. LIGHTING CONTROLS OPC Engine WebTab Service 11 OPC Service Visual Director is a complete Web visualization tool with user interface, its own navigation structure with EIB display and control elements that can be freely positioned. Visual Editor Visual Director Scheduling Service Automation Engine Overview Core Services Core and Webtab Services link the EIB system to the network and enable fast tabular visualization. Applications Tools Get and configure only the functions that you really need to establish a simple, easy to operate interface. The graphical interface is ideal for use by non-technical personnel. It is also used to create links to other building automation functions and systems. IP Router, users and functional expansions can be added at any time. This offers considerable cost benefits. These functions can be divided into four groups: ▪ Webtab Services ▪ Automation Services ▪ OPC Services ▪ Visualization Webtab Services Automation Services This package provides all the functions to control and monitor an LCP3000EZ Lighting Control System. It contains Webtabs, which support linking to the visualization of the lighting control data points in the shortest time possible. The following tools are part of the Core and Webtab Services: ▪ ComBridge Configuration Manager: User interface for management of the IP router, TCP engines and software licenses ▪ ComBridge InfoPoint Configurator: Easy-to-use tool for the creation of Webtabs, OPC data point lists, email services, time jobs and database entries. ▪ Web-based user control: Control of the installation, ComBridge Studio Automation Services deliver application services at the supervisory level. Schedules: Daily programs can be stored and managed centrally using the Scheduling Service. Simply checkmark the week days on which you need to activate. Switching and control commands can be executed according to the schedule. Emails: Critical conditions or events can be monitored so that in event of their occurrence, emails are delivered. The contents of emails can be custom designed, and even sent with an attachment, e.g. with photos or circuit diagrams. This capability enables an easy to visualize system that can expedite Trouble Diagnosis & Repair. Data recording: Using the Database Services, you can write selected events to a database for daily, weekly or monthly scheduled evaluation and reporting. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 11-7 Lighting Controls Web Visualization with ComBridge Studio Overview Visual Director ComBridge Studio offers full OPC server functionality enabling SIEMENS lighting controls integration with other building automation systems (BAS). ComBridge Studio Visual Director is supplementary to Webtab and offers a wide range of design options such as definable navigation, layout of the graphical display and control elements. LIGHTING CONTROLS 11 OPC Services Double Advantage: ComBridge Studio OPC Services can also be used at the same time as other ComBridge Studio applications. For example, the facility can be controlled by OPC at the same time as the workplace is controlled using Webtab or a Visual Director application. It is also possible to ensure access to the system installations for service personnel, or setup an email message services. Quantity Control: Not all data is of interest to the OPC client system. Exchanging all data with the system can lead to huge volumes of information that clogs up the system. In the InfoPoint Configurator you can restrict lists to the required information only. Web Standards: Visual Director is HTML-based. Web assets, such as, navigation, graphics, dynamic HTML, layouts, scripts and dynamic contents in visualization projects can be used repeatedly. Furthermore, HTML know-how is now prevalent in the market and easily available. User Login: Visual Director provides complete system definition, application and use. Each user can be assigned their own start page and navigation allowing for individual system or operational “views” depending upon operator or monitor access level, engineering, maintenance or security function. The user level lets you control the data points each user can access. Visual Editor: Visual Director contains a menu-assisted, pixel-graphic HTML editor with a multitude of functions for creating your Web user interface. 11-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Lighting Controls Wiring Diagrams 5WG1 261-1CB01 Binary Input Device 11 LIGHTING CONTROLS Figure 2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 11-9 Lighting Controls Wiring Diagrams 11 5WG1 512-1CB01 Load Relays Device 3.54" (90 mm) LIGHTING CONTROLS Communications Connector 5.67" (144 mm) From Breaker This type connection allows one breaker to feed more than one relay Figure 3 11-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Lighting Controls General Other Applications: Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 11-11 LIGHTING CONTROLS Figure 4 11 If the LCP3000EZ does not meet your needs SIEMENS can help with your lighting control requirements beyond the capabilities of the LCP3000EZ. SIEMENS has the equipment and technology to do complex installations which require dimming for energy savings. If you require day light harvesting for additional energy savings, SIEMENS is your source. For fluorescent dimming, SIEMENS uses DALI (Digital Addressable Lighting Interface). This is state of the art technology, which uses individually addressable DALI ballasts. This technology allows you to change lighting zones via software without the need of re-wiring the system. It also allows you to monitor ballast and lamp failure, as well as the light output (relay). Contact your nearest SIEMENS Energy and Automation Sales Office for additional information. LIGHTING CONTROLS 11 Notes 11-12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12SPEEDFAX TM 2007-2008 Switchboards Contents Front Connected Switchboards Type SB1, SB2, and SB3 12-3 – 12-6 General Layout Information 12-7 – 12-12 Type RCS 12-13 Multi-Metering Switchboards Type MMS 12-14 Type SMM 12-15 – 12-17 Super Blue Pennant Switchboards 12-18 – 12-23 Service Entrance Switchboards Type BCT 12-24 Type SCT 12-25 Switchboard Replacement and Modifications Kits Residential Commercial Industrial 12-26 SWITCHBOARDS Rear Connected Switchboards 12 Type IPS 12-2 Front Connected Switchboards SWITCHBOARDS 12 Type SB1, SB2 and SB3 General Maximum Flexibility Whether the design is for a 240V ac, 400 ampere system; a 600V ac, 6000 ampere system; or something in between, Siemens front connected switchboards should be considered. Every aspect of the equipment design has been targeted at improving layout convenience, reducing installation costs, and minimizing the impact and cost of system changes. These switchboards provide the rugged construction and service reliability required for industrial plants, hi-rise complexes, hospitals, and commercial buildings, and are built to UL 891 and NEMA PB-2 standards. Type SB1 For Limited Space Applications The Siemens type SB1 switchboard has been specifically designed for those applications where floor space is at a premium. The SB1 contains front-connected protective devices and bus ratings up to 2000 amperes at 600V ac. The rear of all sections align as standard. Type SB2 For Increased Service And More Load Cable Room Siemens SB2 switchboards can have extra depth behind the vertical bus in each distribution section, and contains protective devices and bus rated up to 4000 amperes at 600V ac. The rear of all sections align as a standard. Front and rear alignment is available as an option. Type SB3 For Custom Options The SB3 switchboard is available with protective devices and bus up to 6000 amperes at 600V ac. Options include, but are not limited to, incoming and outgoing busway, ACCESS communication, protective relaying, autothrowover schemes and transformer connections. Siemens SB Switchboards Available Features Maximum Bus Rating Main Devices Feeder Devices Solid State MCCB Customer Metering Utility Metering Density Rated Bussing Accessible SB1 2000A MCCB, VB, HCP, BPS MCCB, VB, HCP, BPS No Yes Yes No Front SB2 4000A MCCB, VB, HCP, BPS, WL (Fixed) MCCB, VB, HCP, BPS, WL, (Fixed) 100,000 AIC Yes Yes Yes Front Alignment Rear Rear STD; Rear/Front Optional For additional information on this product visit our website at www.sea.siemens.com. For application pricing information contact your local distributor or the closest Siemens sales office. 12-2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog SB3 6000A MCCB, VB, HCP, BPS, WL MCCB, VB, HCP, BPS, WL 200,000 AIC Yes Yes Yes Front (up to 38" deep) Front/Rear (Above 38" deep) Rear STD; Rear/Front Optional Integrated Power Systems Switchboards Type IPS General Service Section • accommodate systems up to 4000 amperes. 600V ac maximum in 1-phase 3-wire, 3-phase 3-wire, or 3-phase 4-wire configurations. All components can be built into standard NEMA Type 1 indoor enclosures, or optional NEMA Type 3R outdoor construction. Bus bars are available in standard tin-finished aluminum or optional silver-finished copper. Standard bus is sized on the basis of heat rise criteria, in accordance with UL 891. All bus bars are sized to limit heat rise to 65ºC above a maximum ambient temperature of 40ºC. As an option, conductor material can be sized according to density limits, based on bus material. The applicable limits are: Copper — 1000 amperes sq. in. Aluminum — 750 amperes sq. in. Screw type mechanical connectors (lugs) are provided as standard equipment on all devices. However, compression connectors are available as an option. Distribution Sections • • • • • • • • • • • • • • • • Feeder Breakers (up up 4000 Amp) • Feeder Switches (up up 4000 Amp) • Motor Starter Modules (up to NEMA Size 4) • Main Breaker or Switch up to 4000 Amp • MLO to 2000 Amp Transient Voltage Surge Suppressor Digital Meter • Lighting Contactors (30 to 225 Amp) Local Display Unit (ACCESSTM Communication) • PLC • Time Clock Distribution Transformer Lighting Control Lighting Contactors, PLC, Time Clocks, ATS, Telephone Cabinets HVAC Control Customer Supplied Components Lighting Panelboards For additional information on this product visit our website at www.sea.siemens.com. For application pricing information contact your local distributor or the closest Siemens sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-3 SWITCHBOARDS lPS switchboards are built to UL 891 and NEMA PB-2 standards. Standard height of lPS sections is 90 inches. Optional height of 70 inches is available. Minimum depth of lPS switchboards is 13.75 inches. Optional depths of 20, 28 and 38 inches are available. Some components dictate the use of optional depths. Numerous components are available to fit customer's individual needs. ▪ Lighting Panelboards (MLO and Main Device) ▪ Power Monitoring ▪ Distribution Transformers ▪ ACCESS Communication ▪ Lighting Contactors ▪ Lighting Control ▪ HVAC Control ▪ Building Management ▪ PLC ▪ Automatic Transfer Switch ▪ Motor Starter Units ▪ Backup Generators Typical lPS switchboards consist of one service section and one or more distribution sections that are cable connected. However, lPS switchboards are also available with through bus and pull sections. lPS switchboards will 12 The modular design of the Siemens lPS switchboard allows the user to integrate electrical distribution equipment, power monitoring and environmental controls that typically mount in multiple enclosures into one switchboard line-up. Users have the freedom to configure an arrangement that best fits their individual needs. Optional factory installed interconnection wiring is available to further reduce installation time. lPS Equipment Benefits include: ▪ Less product to handle and install ▪ Lower total installation cost ▪ Less time on the jobsite ▪ Less floor space used for electrical equipment ▪ Single source equipment supplier ▪ Simplified field setup and programming Integrated Power Systems Switchboard (Type IPS) Individually Mounted Devices 3.00 (76.2) 3.00 (76.2) 12 2.50 (63.5) SWITCHBOARDS D CONDUIT AREA TOP & BOTTOM 2.50 (63.5) W 2.50 (63.5) 5.00 (127) 90.00 (2286) Unit Space 75.00 (1905) 5.00 (127) 2.50 (63.5) Dimensions shown in inches and millimeters ( ). 12-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Integrated Power Systems Switchboard (Type IPS) Individually Mounted Devices Unit Space For Components Dimensions in inches (mm) Required Minimum Unit Space Section Width (W) Component Distribution Transformer Distribution Transformer Distribution Transformer Distribution Transformer Distribution Transformer Lighting Contactor 30 through 225 Amp ASCO 920 or Siemens CLH PLC (LOGO!) PLC (S7–200) (Up to 6 in 20" and 25" wide, 9 in 32" wide) 37.50 (953) 20.00 (508) 13.75 (349) SWITCHBOARDS LCP Lighting Control Panel Distribution Transformer 25.00 (635) 12 P3 Panels P1, P2 Panels Time Clock Minimum Section Depth (D) 25.00 (635) (15 KVA) (30 - 45 KVA) (75 - 112.5 KVA) (150 KVA) (225 KVA) (300 KVA) (Up to 4 in 20" and 25" wide, 6 in 32" wide) 37.50 (953) 37.50 (953) 75.00 (1905) 37.50 (953) (Up to 6 in 20" and 25" wide, 9 in 32" wide) (Up to 4 in 20" and 25" wide, 6 in 32" wide) Automatic Transfer Switch (up to 400 Amp) 400-1200 Amp MCCB 1600-2000 Amp MCCB 800-2000 Amp ICCB (WL Breaker) 2500-4000 Amp ICCB (WL Breaker) 800-1200 Amp BPS 1600-2000 Amp BPS 2500-4000 Amp BPS 75.00 (1905) 20.00 (508) 25.00 (635) 32.00 (813) 38.00 (965) 28.00 (711) 46.00 (1168) 38.00 (965) 20.00 (508) 13.75 (349) 32.00 (813) 20.00 (508) 37.50 (953) 75.00 (1905) 37.50 (953) 20.00 (508) 28.00 (711) 38.00 (965) 38.00 (965) 75.00 (1905) 46.00 (1168) NOTE: For required unit space relative to HVAC control and custom specified components, contact Siemens sales. These components can be mixed in a 37.5" (953mm) high compartment. 37.50" (half section) for panels that would fit in to panel cans <=44". 75" (full section) for panels that would fit into panel cans >44". 20.00" for P1/P2 panel (note may be mounted 2 across in >=38" wide sections). 25" for P3 panels (note may be mounted 2 across in >=46" wide sections). Distribution transformer minimum size requirements are based on 150 degree rise TP1 rated units - aluminum or copper bus. Consult Siemens for size requirements related to other ratings including K-Rated. Outdoor sections with transformers must also have rear door added to that section for ventilation. Stacked transformers in a section are limited to 45KVA at this time. Contact Siemens for updated information. For CLH contactor only, up to 6 in 20"and 25" wide section can be mounted and 9 in a 32" wide section. ATS includes generator controls. Contact Siemens sales for details. Emergency power generators are available. Contact Siemens sales for details. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-5 Integrated Power Systems Switchboard SWITCHBOARDS 12 Typical IPS Lineup 13.75 (349) 28.00 (711) 250 A MB P1 LP1 250 A MLO P1 LPD 250 A MLO P1 LP2 250 A MLO P1 LP3 800 A MLO DP1 480Y/ 277 Vac 32.00 (813) 75 KVA XFMR D 38.00 (965) Dimensions shown in inches and millimeters ( ). 12-6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 20.00 (508) General Layout Information (Type SB1, SB2, SB3, IPS) Individually Mounted Service Mains Top Entrance Cables Pull Box Dimensions in Inches (mm) Height Width Max. Amp. Device Rating Type Pull Section NonBussed Bussed UG ��� H1 W1 W2 W3 9300 Meter Minimum Required Depth 600 800 1000 1200 1600 2000 H1 14.00 (356) Main 20.00 (508) W1 32.00 (813) SWITCHBOARDS 400 HJXD6, HHJD6, HHJXD6, JXD2, JXD6, JD6, HJD6, SJD6, SHJD6 HLXD6, HHLD6, HHLXD6, LXD6, LD6, HLD6, SLD6, SHLD6 MXD6, MD6, HMD6, LMXD6, LMD6, HLMD6, HLMXD6, SMD6, SHMD6, 90.00 NM, HM, LM (2286) NXD6, ND6, HND6, SND6, SHND6, HNXD6, NN, HN, LN NXD6, ND6, HND6, SND6, SHND6, HNXD6, NN, HN, LN PXD6, PD6, HPD6, SPD6, HPXD6, NP, HP, LP RXD6, RD6, HRXD6, HRD6 12 Molded Case Circuit Breakers D 20.00 (508) 20.00 ��� (508) Bottom Entrance with Non-Bussed Pull Section 9300 Meter 38.00 (965) 32.00 (813) H1 Main 32.00 (813) 28.00 ��� (711) D W2 W1 Insulated Case Circuit Breakers — Stationary Mounted 800 1200 1600 2000 2500 3000 4000 Type WL Insulated Case Breaker 90.00 (2286) 38.00 (965) 32.00 (813) 38.00 20.00 (508) 32.00 (813) (965) ��� H1 14.00 (356) 20.00 (508) HCP Vacu-Break 90.00 (2286) 38.00 (965) Main D 20.00 (508) 32.00 (813) Bolted Pressure 46.00 (1168) 20.00 ��� (508) 38.00 (965) 32.00 (813) W1 W3 28.00 ��� (711) For EUSERC UGPS dimensions, refer to Siemens Front Connected Switchboard Selection & Application Guide. Optional depths are 28 and 38 inches. ��� Optional depth is 38 inches. ��� 9300 Meter 38.0 (965) Switches 400 600 800 1200 800 1000 1200 800 1000 1200 1600 2000 2500 3000 4000 Bottom Entrance with Bussed Pull Section 28.00 ��� (711) Bottom Entrance 38.00 (965) 9300 Meter H1 Main D W1 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-7 General Layout Information (Type SB1, SB2, SB3, IPS) 12 Main Lug Only — 400A through 2000A Available branch circuit unit space varies depending on amperage of incoming service, lug type and if through bus is L required. If more unit space is required than is shown in the table below, one or more panel mount device distribution sections must be added. L L Cond. Area Top / Bottom Cond. Area Top / Bottom SWITCHBOARDS L K K K K M.L.O. H H Unit Space Unit Space M.L.O. D D W W Top Entrance Bottom Entrance Main Lug Only Unit Space Dimensions in inches (mm) Max. Ampere Rating Suitable For Use Only As Service Av Equipment Unit Space Max. AIC Rating Lugs Height (H) 400 600 800 1200 Available as a user selectable option 200,000 90.00 (2286) Standard 500 kcmil 62.50 (1588) 60.00 (1524) Alternate 750 kcmil 60.00 (1524) 56.25 (1429) Compression 600 kcmil Max. 58.75 (1492) 57.50 (1461) 52.50 (1334) 50.00 (1270) 53.75 (1365) 45.00 (1143) 38.75 (984) 45.00 (1143) 55.00 (1397) Width (W) Minimum Depth (D) Conduit Area K L 13.75 (349) 2.50 (64) 32 or 38 (8.13 or 965) 1600 2000 38.00 (965) 46 in. (1168) width available as an option. See page 12-12 for unit space requirements for disconnect devices. Optional 70" high is also available. Unit space is reduced by 20". If load through bus is required, the available unit space is reduced by 7.50 inches for 400-1200 amp MLO sections. Maximum of 6 disconnect devices only. SUSE service disconnects 1000A or higher on solidly grounded wye systems of more than 150V to ground require ground fault protection. Ground fault uses 10 in. (254 mm) of unit space. See NEC 230-95 for additional details. This applies to branch devices 1000A or larger on non-service equipment unless ground fault protection is provided upstream at the service. See NEC 240-13 for further information. Optional section depths are 20", 28" and 38." 12-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3.00 (76) General Layout Information (Type SB1, SB2, SB3, IPS) Panel Mounted MCCB — 400A through 1200A IPS service sections can house both labels, but include no provisions for a main service disconnect device and utility metering. branch disconnects. Switchboards can be furnished with “Suitable for Branch circuit device unit space varies, Use Only as Service Equipment” depending on the rating and consequent 400 -1200A Main Breaker With GFP L L K SWITCHBOARDS L 12 400-1200A Main Breaker Without GFP physical size of the main disconnect device. If more unit space is required than is shown in the tables below, one or more additional panel mounted device distribution sections must be added. L K Conduit Area Top or Bottom Conduit Area Top or Bottom K K MCB Unit Space H Unit Space GF H M/B D D W W Fig. 1 Top Entrance (Invert for bottom entrance) Fig. 2 Bottom Entrance (Invert for top entrance) Main Breaker with or without Ground Fault Protection Dimensions in inches (mm) Max. Ampere Rating 400 600 800 1000 1200 Conduit Area Breaker Type JXD2, JXD6, JD6, HJD6, HJXD6, HHJD6, HHJXD6, SJD6, SHJD6 LXD6, LD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6 LMD6, LMXD6, HLMD6, HLMXD6, NM, HM, LM MXD6, MD6, HMD6, HMXD6 SMD6, SHMD6 NXD6, ND6, HND6, HNXD6, NN, HN, LN SND6, SHND6 NXD6, ND6, HND6, HNXD6, NN, HN, LN SND6, SHND6 Height (H) Unit Space Width (W) Minimum Depth (D) K L Main Location Service Entrance Label 56.25 (1429) 32.00 (813) Yes 90.00 (2286) 13.75 (349) 53.75 (1365) 2.50 (64) 3.00 (76) Top or Bottom 52.50 (1334) 40.00 (1016) 52.50 (1334) 38.00 (965) 40.00 (1016) Yes 52.50 (1334) 40.00 (1016) Ground fault, if applied, uses 10 in. (254 mm) of unit space. See page 12-12 for unit space requirements for disconnect devices. Available unit space for 400 and 600 amp main breaker sections is reduced to 53.75 if load side through bus is required. Optional section depths are 20", 28" and 38". Optional 70" high is also available. Unit space is reduced by 20". 46 in. (1168 mm) wide if 750 kcmil or compression lugs required. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-9 General Layout Information (Type SB1, SB2, SB3, IPS) Panel Mounted HCP Switch Main — 400A through 1200A 400 - 1200A HCP L L K Conduit Area Top or Bottom 12 K SWITCHBOARDS 400-1200A HCP Main Switch H Unit Space D W��� Top Feed Bottom Feed Top Entrance (Invert for Bottom Entrance) 400 — 1200A HCP Switch Main Dimensions in inches (mm) Max. Ampere Rating 400 600 800 1200 Height (H) Unit Space ��� Width (W) ��� Minimum Depth (D) ��� Conduit Area K L Main Location 90.00 ��� (2286) 46.25 (1175) 38.00 (965) 13.75 (349) 2.50 (64) Top or Bottom ��� 46 in. (1168 mm) width available as an option. See page 12-12 for unit space requirements for disconnect devices. ��� Optional section depths are 20", 28" and 38". ��� Optional 70" high is also available. Unit space is reduced by 20". ��� 12-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3.00 (76) Service Entrance Label Yes General Layout Information (Type SB1, SB2, SB3, IPS) Panel Mounted Devices Through-Bus Fed Through-Bus Fed Distribution Sections L L K Conduit Area Top or Bottom K 12 SWITCHBOARDS Bus Bar H2 Unit Space Through Bus H1 ➀ D W Through-Bus Fed Dimensions Dimensions in Inches (mm) Maximum Riser Amperage 2000 3000 With Maximum Through-Bus Amperage 2000 2500 & 3000 4000 Height Width H1 Unit Space H2 65.00 (1651) 32.00 or 38.00 (813) (965) 62.50 (1588) 38.00 or 46.00 (965) (1168) 90.00 (2286) 4000 W Minimum Section Depth (D) 20.00 (508) Conduit Area K L 2.50 (64) 3.00 (76) See page 12-12 for unit space requirements for disconnect devices. Optional 70" high is available. Unit space is reduced by 20. Optional section depths are 28" and 38". 46 inches (118 mm) width optional. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-11 General Layout Information (Type SB1, SB2, SB3, IPS) Unit Space for Panel Mount Disconnect and Miscellaneos Components Unit Space Requirements — Molded Case Circuit Breakers (Mains and Branches) Dimensions in inches (mm) Max. Ampere Rating SWITCHBOARDS 12 100 125 225 250 400 600 800 1200 Device Type BL, BLH, HBL, BQD, NGB, NEB, HEB ED4, HHED6 ED4, ED6, HED4, HHED6, NGB, NEB, HEB HED4, HHED6, ED4, NGB, ED6 with accessories CED6 CED6 with accessories QJ2, QJH2, QJ2-H,HQJ2-H FXD6, FD6, HFD6, HFXD6, HHFD6, HHFXD6 CFD6 JX2, JXD6, JD6, HJD6 HJXD6, HHJD6, HHJXD6 SJD6, SHJD6 LXD6, LD6, HLD6, HLXD6, HHLD6, HHLXD6 SLD6, SHLD6 LMD6, LMXD6, HLMD6, HLMXD6 MXD6, MD6, HMD6, HMXD6 SMD6, SHMD6 NM, HM, LM NXD6, ND6, HND6, HNXD6 SND6, SHND6, NN, HN, LN Total Poles Available 1P 2P Unit Space Required Twin Mounted Single Mounted Enclosure Minimum Width — 32.00 (813) 5.00 (127) 8.75 (222) — 38.00 (965) 8.75 (222) 32.00 (813) 10.00 (254) 38.00 (965) ��� — 8.75 (222) 38.00 (965) 1 — 10.00 (254) 38.00 (965) ��� 6 3P 2 2 3.75 (95) 6.25 (159) 2 3.75 (95) 6.25 (159) 2 5.00 (127) — 1 2 — — 1 1 2 — — 8.75 (222) 1 — 1 1 — Unit Space Requirements For Miscellaneous Components Unit Space Requirements — Fusible Switches (Mains and Branches) Dimensions in inches (mm) Max Amp Rating 30-30 30-30 30-60 60-60 60-100 100-100 200-200 100 200 400 600 400 - 1200 Switch Type 240V Twin 2.50 (64) ��� Unit Space Required 600V Single Twin — Single Enclosure Minimum Width 5.00 (127) — Vacu-Break — 32.00 (813) 7.50 (191) 10.00 (254) ��� — HCP 7.50 (191) 10.00 (254) ��� 7.50 (191) — 7.50 (191) 10.00 (254) — 10.00 (254) 15.00 (381) 16.25 (413) — 15.00 (381) 38.00 (965) 16.25 (413) ��� 46 in. (1168mm) wide if 750 kcmil or compression lugs required. The 2.5 in. (64) high unit is suitable for NEC Class H, K1 and K5 fuses only. Class R rejection type fuse holders are not available. ��� Unit rated 600V, factory configured to accept 250V Class K or R fuses. Field convertible to accept Class J fuses. ��� Factory configure to accept Class J fuses only. ��� 12-12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Component Local Display ADR 9000 (SRTU) Transient Voltage Surge Suppressor (TPS) 9200A Digital Meter 9200B Digital Meter 9200C Digital Meter 9300 Digital Meter 9330 Digital Meter 9350 Digital Meter Lighting Contactor 30 to 225 Amp Siemens CLH Lighting Contactor 30 to 225 Amp ASCO 920 Time Clock Sangamo, Tork or Paragon PLC (LOGO!TM and S7) Unit Space in inches (mm) 10.00 (254) 10.00 (254) 10.00 (254) 10.00 (254) 10.00 (254) 10.00 (254) 10.00 (254) 10.00 (254) 10.00 (254) 20.00 (508) 10.00 (254) 10.00 (254) Rear Connected Switchboards Type RCS General Switchboard Type RCS Mounting WL Insulated Case Circuit Breaker Drawout Mount WL LV Power Circuit Breaker Drawout Mount Main Devices Individual 400-5000A 400-5000A Branch Devices Individual 400-5000A 400-5000A RCS switch boards utilize Type WL insulated case and/or low voltage power circuit breakers with drawout mountings. Features and benefits include high breaker density, 100kA standard short circuit bus bracing and three levels of horizontal bus. Options include insulated/ isolated bus, Dynamic Arc Flash Sentry, ModBus Communication and intelligent power monitoring. For additional information on this product visit our website at www.sea.siemens.com. For application pricing information contact your local distributor or the closest Siemens sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-13 SWITCHBOARDS can be requested to secure the outgoing cables. The front and rear of all sections align and are designed for mounting away from the wall. RCS switchboard will accommodate requirements up to 6000 ampere and 600 volts. The main bus can be specified for 400 to 6000 ampere rating. Main, tie and branch devices are available in amperage ratings up to 6000 amps. RCS switchboards can be indoor (NEMA 1) or outdoor (NEMA 3R) construction. 12 Siemens RCS switchboards differ from the front connected (Type SB1, SB2, SB3) design primarily in the distribution sections. In the distribution section the branch feeders are individually mounted. Because of this method of mounting, access to the outgoing cable terminals must be from the rear of the unit. Bus bar extensions from the feeder devices are run to the rear of the RCS section stopping before the conduit area for easy access and cable connection. An optional cable management system Multi-Metering Switchboards SWITCHBOARDS 12 Type MMS In today’s commercial and industrial environments, the electrical metering requirements vary according to the specification of the development site. Siemens offers a solution with high quality multi-metering switchboards that meet the non-EUSERC area requirements. The MMS switchboard meets the requirements of member utilities and municipalities with these dependable commercial switchboards. Features ▪ Up to 4000A main service 208Y/120V, three phase/four wire 480Y/277V, 3-phase 4-wire ▪ 100A, 200A and 320A tenant mains are available ▪ UL listed and labeled General ▪ NEMA “Non-EUSERC” Design ▪ Hot sequence metering is standard; cold sequence also available ▪ 50,000A symmetrical bus bracing is standard; above 50,000A available upon request. ▪ All meter sockets are pre-wired for 100A, 200A or 320A devices ▪ Copper or Aluminum bus available ▪ Units are front accessible. ▪ NEMA Type 1 and Type 3R construction available ▪ Available with optional cable pull sections ▪ Sockets include lever type manual by-pass ▪ Load cable exit top or bottom ▪ Common depth for main and metering sections upon request ▪ Ring-less type meter cover design For additional information on this product visit our website at www.sea.siemens.com. For application pricing information contact your local distributor or the closest Siemens sales office. 12-14 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Multi-Metering Switchboards Type SMM ▪ Up to 4000A main service 120/240V 1-phase 3-wire 240/120V 3-phase 4-wire 208Y/120V 3-phase 4-wire 480Y/277V 3-phase 4-wire SWITCHBOARDS Features General ▪ 200 amp continuous duty meter sockets ▪ Meets EUSERC requirements ▪ UL listed and labeled ▪ Hot sequence metering standard cold sequence metering optional ▪ Test blocks are standard ▪ Copper or Aluminum bus ▪ 65,000A Sym bracing standard (higher bracing rating available if required) ▪ Type NEMA Type 1 and Type 3R construction available ▪ Meets UL891 and NEMA PB2 standards ▪ Rear cable barriers available for top load cable exist ▪ Ring type meter cover design 12 Completely engineered and assembled, Siemens SMM commercial metering switchboards require minimal field assembly. They are UL listed and labeled and meet all EUSERC standards. SMM switchboards are built to meet the rugged requirements of the western United States. These units can be modified to meet any additional requirements of member utilities and municipalities. For a high quality dependable commercial metering switchboard consider the West Coast SMM design. For additional information on this product visit our website at www.sea.siemens.com. For application pricing information contact your local distributor or the closest Siemens sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-15 Multi-Metering Switchboards Type SMM General Figure B 햹 20" 32" Figure C 햸 Figure D햺 SWITCHBOARDS 12 Figure A햸 20" 32" 26" SMM/SMD Sections with Space for Tenant Mains/Meter Sockets Table 7.4.6.19 SMM 햲 Sections With Space For CB Mains And Sockets 햳 햴 햵 Sockets Figure 3 6 A B Table 7.4.6.20 SMD 햶 Sections With Space For CB Mains And Sockets 햳 햴 햵 3 6 A B Table 7.4.6.21 SMM 햲 Sections With Space For T-Fuse Mains And Sockets 햳 햴 햵 3 6 A B Table 7.4.6.22 SMD 햶 Sections With Space For T-Fuse Mains and Sockets햳 햴 햵 3 6 A B Table 7.4.6.23 SMM 햲 Sections With Space For VB Mains And Sockets 햳 햴 햵 햷 2 6 2 6 C D C D Table 7.4.6.24 SMD 햶 Sections With Space For VB Mains And Sockets 햳 햴 햷 2 6 2 6 C D C D NOTE: Component priced Meterboards allow for any combination of 100 and 200 ampere tenant mains or blank positions. Select the base structure, meter sockets and tenant mains accordingly. 햲 SMM 햵 When 햳 Price 햶 SMD sections–Cross bus from 800–2500 ampere. Sections 20" deep. sockets with tenant mains from Table 7.4.6.25, 7.4.6.26, 7.4.6.27. Price sockets only from Table 7.4.6.28. 햴 Cross bus is not included. Price from Table 7.4.6.29 or 7.4.6.30. 12-16 load cables exit top of section, rear load barrier (RLB) must be priced. See Table 7.4.6.31. sections required for cross bus exceeding 2500 ampere. Sections 28" deep. 햷 Fuses not included. For Class J fuse provisions, change R to J. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햸 26" 햹 38" 햺 35" wide for Outdoor Type 3R. wide for Outdoor Type 3R. wide for Outdoor Type 3R. Multi-Metering Switchboards Type SMM General Components Table 7.4.6.25 — Tenant Circuit Breaker With Meter Socket 햳 240 Volt Option 햲 100 BQ 100 BQH 100 HBQ 200 QJ2 200 QJH2 200 QJ2-H 100 ED4 100 NGG 100 HED4 100 HEG 200 FD6 200 HFD6 100 ED4 100 NGG 100 HED4 100 HHED6 100 HEG 200 FD6 200 HFD6 200 HFD6 01 02 No. of Poles I.C. 2 3 2 3 2 3 110,000 110,000 122,000 122,000 165,000 165,000 2 3 2 3 2 3 110,000 110,000 122,000 122,000 142,000 142,000 2 3 2 3 2 3 2 3 165,000 165,000 165,000 165,000 100,000 100,000 100,000 100,000 2 3 2 3 165,000 165,000 100,000 100,000 2 3 2 3 2 3 2 3 2 3 118,000 118,000 125,000 125,000 142,000 142,000 165,000 165,000 165,000 165,000 2 3 2 3 2 3 135,000 135,000 165,000 165,000 165,000 165,000 SWITCHBOARDS Breaker Type 12 Ampere Rating 480 Volt 03 햲 Order 100A and 200A tenant circuit breakers from the same option only. Do not mix breakers from different options. 햳 Meter socket with Test Block included. For socket only, without tenant disconnect, price from Table 7.4.6.28. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-17 Super Blue Pennant Switchboards Warehouse Stock General SWITCHBOARDS 12 Features Ampere Ratings 400–600–800 Ampere Circuit Breaker Main 400–600 Ampere Fusible Vacu-Break Main Voltage Ratings 120/240 Volts 1-Phase, 3-Wire 240/120 Volts 3-Phase, 4-Wire Delta 240 Volts 3-Phase, 3-Wire Delta 208Y/120 Volts 3-Phase, 4-Wire 480Y/277 Volts 3-Phase, 4-Wire 480 Volts 3-Phase, 3-Wire Delta 12-18 I.C. Ratings The short circuit current rating is limited to the lowest current interrupting rating, at the supply voltage, of any device installed. Only Siemens breakers with short circuit interrupting ratings equal to or greater than the marked short circuit current rating shall be used for replacement or additions. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog The Super Blue Pennant service entrance switchboard is designed to meet the needs of main over current protection with distribution devices for medium duty service applications. Main service disconnects can be either Siemens Vacu-Break fusible switch or Siemens molded case circuit breakers. Either type of device provides dependable performance with series rated combinations available. The switchboard is labeled as “suitable for use only as service equipment”. Super Blue Pennant switchboards meet EUSERC utility requirements. □ A NEMA Type 1 indoor or Type 3R outdoor self-contained enclosures are constructed of code gauge steel and painted ANSI-61 light gray. □ B Rating label information is clearly visible on the equipment front panel. Danger, short circuit rating labels and UL listing label present necessary information to conform with NEMA Standard PB-2. □ C Metering and test block provisions meet EUSERC utility specifications. □ D Incoming main lugs are mechanical screw-type mounted on studs accepting a wide range of cable sizes. □ E Barriered hot sequence utility metering and fully bussed power company current transformer compartment meet EUSERC utility standards. □ F Service disconnect can be fusible Vacu-Break switch through 200,000 AIC or circuit breaker with maximum rating of 65,000 AIC at 240 volts and 50,000 AIC at 480 volts. □ G Distribution panel kits are optional and field addable with ratings of 400–800 amperes. Up to 40 branch circuit provisions available, 18 branch circuit minimum. ▪ High interrupting capacity subfeed kits with molded case circuit breaker ratings of 225 or 400 amperes. ▪ Series rated combinations are available. Consult sales office. ▪ Contact sales office for warehouse stocking locations. Super Blue Pennant Switchboards Type 1 — Indoor, Type 3R — Outdoor Dimensions Type 1 — Indoor Type 3R — Outdoor Weatherproof 12 ( ( ) ) SWITCHBOARDS ( 2.875" 26.25" ) 3.875" 2.875" 5.875" 3.875" 2.875" 14.5"12.5" 8.75"14.5" 15.625" 2.875" Description Dimensions (inches) A B C Description Dimensions (inches) A B C Without Lug Landing 46 14 12 Without Lug Landing 53 15 13 With Lug Landing 58 26 24 With Lug Landing 65 27 25 For inches / millimeters conversion, see conversion table in Application Data section. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-19 Super Blue Pennant Switchboards Main Circuit Breaker Selection Main Circuit Breaker SWITCHBOARDS 12 Main Device Ampere Rating 400 Ampere Line Lugs (2)—3⁄0-500 kcmil (Copper or Aluminum) Breaker Rated 65,000A IR Symmetrical at 240 Volts 35,000A IR Symmetrical at 480 Volts Type JD6 600 Ampere Line Lugs (2)—3⁄0-500 kcmil (Copper or Aluminum) Breaker Rated 65,000A IR Symmetrical at 240 Volts 35,000A IR Symmetrical at 480 Volts Type LD6 800 Ampere Line Lugs (3)—3⁄0-500 kcmil (Copper or Aluminum) Breaker Rated 65,000A IR Symmetrical at 240 Volts 50,000A IR Symmetrical at 480 Volts Type MD6 Service Voltage Indoor Outdoor Meter Distribution Approximate Weight (lbs.) Socket Kits Indoor Outdoor Clips Available 햴 Indoor Outdoor 120/240; 1-Phase, 3-Wire PB224 WPB224 4005.00 7071.00 240/120; 3-Phase, 4-Wire Delta 240; 3-Phase, 3-Wire 208Y/120; 3-Phase, 4-Wire PB424 WPB424 5000.00 8008.00 480Y/277; 3-Phase, 4-Wire 480; 3-Phase, 3-Wire PB444 WPB444 120/240; 1-Phase, 3-Wire PB226 240/120; 3-Phase, 4-Wire Delta 240; 3-Phase, 3-Wire 208Y/120; 3-Phase, 4-Wire Catalog Number PQ2630 PQ2612 320 1050 15 PQ4630 PQ4612 335 1060 6856.00 9889.00 15 PE4630 PF4606 335 1060 WPB226 5125.00 8151.00 5 PQ2630 PQ2612 320 1050 PB426 WPB426 6981.00 10015.00 15 PQ4630 PQ4612 335 1060 480Y/277; 3-Phase, 4-Wire 480; 3-Phase, 3-Wire PB446 WPB446 10476.00 13542.00 15 PE4630 PF4606 335 1060 120/240; 1-Phase, 3-Wire PB228 WPB228 6612.00 9656.00 5 PQ2840 PQ2816 460 1090 PB428 WPB428 9053.00 12104.00 15 PQ4840 PQ4818 475 1090 PB448 WPB448 13909.00 16930.00 15 PE4840 PF4809 475 1090 240/120; 3-Phase, 4-Wire Delta 240; 3-Phase, 3-Wire 208Y/120; 3-Phase, 4-Wire 480Y/277; 3-Phase, 4-Wire 480; 3-Phase, 3-Wire For inches / millimeters conversion, see conversion table in Application Data section. 햲 Price List Price $ 햲 5햳 햳 햳 햳 For 6-jaw requirements, order 6th clip kit from accessories. to Distribution Panel Kits for list prices. = Warehouse Stock 햴 Refer does not include load side lugs, Distribution Panel or Subfeed Kits. 12-20 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule SWBD Super Blue Pennant Switchboards Main Fusible Switch Selection Main Fusible Switch 햲 Main Device Ampere Rating Meter Distribution Approximate Weight (Lbs) Socket Kits Outdoor Clips Available 햵 Indoor Outdoor List Price $ 햳 Indoor Outdoor Indoor 120/240; 1-Phase, 3-Wire PF224 WPF224 4697.00 7549.00 240/120; 3-Phase, 4-Wire Delta 240; 3-Phase, 3-Wire 208Y/120; 3-Phase, 4-Wire PF424 WPF424 5726.00 8721.00 480Y/277; 3-Phase, 4-Wire 480; 3-Phase, 3-Wire PF444 WPF444 6714.00 9498.00 120/240; 1-Phase, 3-Wire PF226 WPF226 5761.00 8927.00 240/120; 3-Phase, 4-Wire Delta 240; 3-Phase, 3-Wire 208Y/120; 3-Phase, 4-Wire PF426 WPF426 7942.00 10936.00 480Y/277; 3-Phase, 4-Wire 480; 3-Phase, 3-Wire PF446 WPF446 10225.00 13024.00 For inches / millimeters conversion, see conversion table in Application Data section. 햲 Fuses 햴 For PQ2630 PQ2612 365 1094 15 PQ4630 PQ4612 375 1110 15 PE4630 PF4606 375 1110 PQ2630 PQ2612 370 1100 15 PQ4630 PQ4612 390 1110 15 PE4630 PF4606 390 1120 5햴 5햴 6-jaw requirements, order 6th clip kit from accessories. 햵 Refer to Distribution Panel Kits for list prices. SWITCHBOARDS 600 Ampere Line Lugs (2)—3⁄0-500 kcmil (Copper or Aluminum) 200,000 AIC maximum at 600 Volts Catalog Number 12 400 Ampere Line Lugs (2)—3⁄0-500 kcmil (Copper or Aluminum) 200,000 AIC maximum at 600 Volts Service Voltage = Warehouse Stock not included. does not include load side lugs, Distribution Panel or Subfeed Kits. 햳 Price Discount Schedule SWBD Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-21 Super Blue Pennant Switchboards Components Selection SWITCHBOARDS 12 Main Device (Circuit Breaker or Fusible Switch) Load Side Lugs — Discount Schedule SWBD Ampere Rating Description Catalog Number Wire Range List Price $ 400 600 For Fusible Switch LKF4 LKF6 (1)—3/0-750 kcmil (Cu or Al) (2)—3/0-500 kcmil (Cu or Al) 227.00 227.00 400 600 800 For Circuit Breaker LKB4 LKB6 LKB8 (1)—600-750 kcmil (Cu or Al) (2)—3/0-350 kcmil (Cu or Al) (2)—600-750 kcmil (Cu or Al) 227.00 227.00 451.00 Distribution Panel Kits — Discount Schedule SWBD Ampere Rating Number and Type of Breaker Poles QP or HQ ED4 QJ2 or QJH2 FXD6 Catalog Number 30 — — — PQ2630 12 — 12 — PQ2612 240/120V; 3-Phase, 4-Wire Delta 240V; 3-Phase, 3-Wire 208Y/120V; 3-Phase, 4-Wire 30 — — — PQ4630 12 — 12 — PQ4612 480Y/277V; 3-Phase, 4-Wire — 30 — — 480V; 3-Phase, 3-Wire — 12 — 6 40 — — — PQ2840 12 — 16 — PQ2816 40 — — — PQ4840 12 — 18 — PQ4818 Voltage 120/240V; 1-Phase, 3-Wire 400 and 600 120/240V; 1-Phase, 3-Wire 800 240/120V; 3-Phase, 4-Wire Delta 240V; 3-Phase, 3-Wire 208Y/120V; 3-Phase, 4-Wire 480V; 3-Phase, 3-Wire List Price $ Weight 1105.00 39 1373.00 42 PE4630 1163.00 42 PF4606 1163.00 65 1806.00 65 2283.00 70 — 40 — — PE4840 1806.00 65 — 12 — 9 PF4809 2552.00 70 Circuit Breaker Subfeed Kits: (Breakers Not Included) — Discount Schedule SWBD Description Catalog Number List Price $ For FXD6-225A 2 or 3-pole PSFFJ6 595.00 For JXD6, JD6, HJD6 400A 2 or 3-pole PSFJL6 913.00 For inches / millimeters conversion, see conversion table in Application Data section. Price includes phase and neutral load lugs and neutral link assembly. FXD6 requires 3-pole space. 2-pole 12-22 Price includes branch neutral and disconnect link assembly. 1-pole breakers must not be connected to “B” phase. 1-pole breakers must not be connectedto “B” phase. 2-pole breakers must be rated 240V. FXD6 circuit breakers are limited to 225A maximum. Price from Molded Case Circuit Breaker section. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog = Warehouse Stock Discount Schedule SWBD Super Blue Pennant Switchboards Accessories Selection Description Catalog Number List Price $ Underground Pull Section or Full Height Section For Load Wiring — Discount Schedule SWBD PUG14 WPUG14 1597.00 3370.00 26" Wide (24" opening) — indoor 27" Wide (24" opening) — outdoor PUG26 WPUG26 1866.00 3879.00 10" Wide (load wiring) PLW10 12 14.5" Deep 90" High 14" Wide (12" opening) — indoor 15" Wide (12" opening) — outdoor SWITCHBOARDS 853.00 Lug Landing Kits — Discount Schedule SWBD (Requires Catalog Number PUG26 or WPUG26) 400A 1-Phase, 3-Wire or 3-Phase, 4-Wire PLL44 햲 814.00 600A 1-Phase, 3-Wire or 3-Phase, 4-Wire PLL46 햲 1221.00 800A 1-Phase, 3-Wire or 3-Phase, 4-Wire PLL48 햲 1435.00 400A 250/600V SSRK35 137.00 600A 250/600V SSRK36 137.00 400A 250V W49814 330.00 400A 600V W49816 395.00 600A 240V W49813 459.00 600A 600V W49815 330.00 400A 240V TFAK52 102.00 400A 600V TFAK55 151.00 600A 240V TFAK62 120.00 600A 600V TFAK65 174.00 Meter Compartment Door (32" Wide x 15" High for “S” base socket with test block cutout (order necessary meter base from items below) PSP32 510.00 Meter Compartment Door (32" Wide x 30" High) for 2 “S” base meters with mounting provisions for test block and printing demand meter (order meter base from table below) Left Hand Hinge or Right Hand Hinge PSDP32 577.00 Blank Meter Compartment Door (32" Wide x 15" High) PBP32 243.00 5 Clip Meter Socket with ring PMS5 260.00 6 Clip Meter Socket with ring PMS6 294.00 8 Clip Meter Socket with ring PMS8 317.00 13 Clip Meter Socket with ring PMS13 577.00 15 Clip Meter Socket with ring PMS15 612.00 “R” Fuse Clip Adapter Kit (Set of 3) — Discount Schedule VBSS “J” Fuse Clip Adapter Kit (Set of 3) — Discount Schedule VBSS “T” Fuse Clip Adapter Kit (One Pole Kit) — Discount Schedule VBSS Optional Meter Sockets and Doors — Discount Schedule SWBD Filler Plates — Discount Schedule MCCB QP-HQP-QJ2-QJ2H-QJH2 QF3 2.80 Handle Blocking and Padlock Devices — Discount Schedule MCCB Blocking (QP-HQP 1, 2 and 3-pole) QL1 Blocking (QJ2, QJ2-H, QJH2) QJHS1 13.40 8.30 Blocking (ED2, ED4, ED6) E2HBL 16.00 Padlock (QP-HQP) QLD3 Padlock (QJ2, QJ2-H, QJH2) HL9419 15.10 Padlock (ED2, ED4, ED6) ED2HPL 16.00 PEGB42 101.00 8.40 Equipment Ground Bus –– Discount Schedule SWBD For inches / millimeters conversion, see conversion table in Application Data section. Discount Schedule SWBD 햲A PUG26 or WPUG26 Underground pull section is required when using these lug landing kits. = Warehouse Stock Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-23 Circuit Breaker, Fusible Application Switchboards Circuit Breaker — BCT Service Cubicle Selection Service Entrance Equipment With Provisions For Metering Current Transformers Service Entrance Circuit Breaker SWITCHBOARDS 12 COLD SEQUENCE METERING STANDARD For Hot Sequence Metering Invert Unit and Breaker ▪ Available with current transformer provisions on load side and can be inverted for current transformer provision on line side. ▪ Tamperproof enclosure with hinged door over current transformer compartment with latch for utility company sealing. ▪ Current transformer provisions are adjustable for use with 12" or 14.5" primary bar type current transformer. ▪ Indoor construction for floor mounting only. ▪ All units supplied as top feed cold metering only. Units may be field modified as shown in the Available Configurations listed in the table below. ▪ Listed by Underwriters Laboratories’ as suitable for use as service equipment only. Connectors (Per phase and neutral) Ampere Rating Connectors Suitable for Cu or Al 400A (1)–4/0–500 kcmil or (2)–250 kcmil 600A (2)–4/0–500 kcmil 800A (3)–250–500 kcmil 1000–1200A Catalog Number BCT436JXD6 BCT436HJD6 BCT636LXD6 BCT636HLD6 BCT Switchboard (4)–250–500 kcmil List Price $ 6805.00 Symmetrical Amps Interrupting Capacity 240V 480V 600V 65,000 35,000 25,000 10922.00 100,000 65,000 35,000 65,000 35,000 25,000 12467.00 100,000 65,000 35,000 9720.00 BCT836MXD6 12752.00 65,000 50,000 25,000 BCT836HMD6 17194.00 100,000 65,000 50,000 BCT1036NXD6 15220.00 65,000 — — BCT1036HND6 20066.00 100,000 — — BCT1236NXD6 20135.00 65,000 — — BCT1236HND6 25777.00 100,000 — — PTE Ampere Rating System Voltage 400 600 800 1000 1200 1439.00 Potential Transformer Enclosure Height Width Depth Top Feed Cold Seq. Top Feed Hot Seq. Bottom Feed Cold / Hot Seq. ⻫ 120/240V 1-Phase, 3-Wire ⻫ ⻫ 208Y/120V 3-Phase, 4-Wire ⻫ ⻫ 240V 3-Phase, 3-Wire ⻫ ⻫ 480Y/277V 3-Phase, 4-Wire ⻫ ⻫ 480 or 600V 3-Phase, 3-Wire ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ 70 32 13.75 ⻫ ⻫ 208Y/120V 3-Phase, 4-Wire 240V 3-Phase, 3-Wire 90 32 13.75 ⻫ ⻫ ⻫ ⻫ — — 20 For inches / millimeters conversion, see conversion table in Application Data section. 12-24 Available Configurations Dimensions (inches) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 20 10 = Warehouse Stock Discount Schedule SWBD Service Entrance Switchboards Fusible Switch — SCT Service Cubicle Selection Service Entrance Fusible Switch ▪ Indoor construction for floor mounting only. ▪ Compact tamperproof enclosure with hinged door over current transformer compartment with latch for utility company sealing. ▪ Listed by Underwriters Laboratories’ as suitable for use as service equipment only. 12 SWITCHBOARDS ▪ Quick-Make — Quick-Break Fusible dead front switch. ▪ Interlocked door over fuses with provisions for padlocking switch. ▪ Door over current transformer section with latch arrangement for utility company seal. ▪ Current transformer provisions are adjustable for use with 12" or 14.5" primary bar type current transformer. Connectors (Per phase and neutral) Ampere Rating Connectors Suitable for Cu or Al 400A (1)–4/0–500 kcmil or (2)–250 kcmil 600A (2)–4/0–500 kcmil 800A (3)–250–500 kcmil 1000–1200A (4)–250–500 kcmil Ampere Rating Fuse Clip Symmetrical Amperes Interrupting Capacity 400–600 R 200,000 800–1200 L 100,000 Catalog Number SCT Switchboard List Price $ Ampere Rating Dimensions (inches) Cold Sequence Hot Sequence SCT432 LSCT432 7314.00 400 120/240V 1-Phase, 3-Wire SCT632 LSCT632 9161.00 600 208Y/120V 240V 3-Phase, 4-Wire 3-Phase, 3-Wire SCT436 LSCT436 8516.00 400 480Y/277V 3-Phase, 4-Wire SCT636 LSCT636 9755.00 600 480 or 600V 3-Phase, 3-Wire SCT836 LSCT836 14244.00 800 All — 208Y/120V 240V 3-Phase, 4-Wire 3-Phase, 3-Wire SCT1236 LSCT1236 17695.00 For inches / millimeters conversion, see conversion table in Application Data section. Discount Schedule SWBD 1200 System Voltage Height Width Depth 90 32 20 = Warehouse Stock Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 12-25 Switchboard Replacement and Modification Kits SWITCHBOARDS 12 Replacement Data, Accessories, Modifications Connecting Strap Kits 햲 — Circuit Breaker Discount Schedule SWBD For use with Series 5 or 6 CDP Circuit Breaker Panelboards or FC20, FCI, FCII, CDP-6, VB-6, SB1, SB2, and SB3 Switchboards — includes copper straps, cover plates and necessary hardware for switchboards manufactured since 1974. Replacement strap kits for RCIII switchboards contact your local sales office. Breaker Type Strap Kit Catalog 햳 Number BL, BLH, HBL, BQD SBLBD NEB, HEB SEBD NGB List Price $ Height (inches) Mounting 902.00 3.75 D 902.00 3.75 D SNBD 902.00 3.75 D ED2, ED4, ED6, HED4, HED6, HHED6 6E62 1074.00 3.75 D CED6 6CLE2 1074.00 3.75 D QJ2, QJH2, QH2-H 6QJ2 1942.00 5. D FD6, FXD6, HFD6, HFXD6, HHFD6, HHFXD6 6F62 1942.00 5. D CFD6 6CLF1 1973.00 5. S JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6 Single Branch 6JJ61 2695.00 8.75 S JXD2, JD6, JXD6, HJD6, HJXD6, HHJD6, HHJXD6 Double Branch 6JJ62 2983.00 8.75 D CJD6 6CLJ1 2695.00 8.75 S SJD6, SHJD6 6SJL1 2695.00 8.75 SCJD6 6SCJ1 2695.00 LD6, LXD6, HLD6, HLXD6 6LL61 3207.00 CLD6 6CLL1 SLD6, SHLD6 SCLD6 Selection Filler Plates — Discount Schedule SWBD For use with Series 5 or 6 CDP Circuit Breaker Panelboards, FC-20, Class II, FCI, FCII, SB1, SB2, and SB3 Switchboards. Breaker Frame BQ, BQH, HBQ, E2, E4, E6, HE4, HE6, E2-A, E4-A, E6-A, HE4-A or HE6-A and ED2, ED4, ED6, HED4, HED6 Filler Plate Catalog Number List Price $ Notes QF3 2.80 Per Pole Note: When a front filler plate is not completely filled with breakers, the openings in the unused space must be closed with 1-pole filler plates from table. Connecting Strap Kits Vacu-Break 햲 and HCP Discount Schedule SWBD For use with VB-5, VB-6, FC-20, FC-I, FC-II, SB1, SB2 and SB3 Switchboards. Includes copper straps and necessary hardware for Switchboards manufactured since 1974. Ampere Rating Unit Height (inches) Catalog Number 5, 71⁄2 5, 71⁄2 5, 71⁄2 71⁄2 71⁄2 VB657 S 30-30 30-60 60-60 60-100 100-100 8.75 S 100 71⁄2 8.75 S 200 71⁄2, 10 VB671 471.00 3207.00 8.75 S 200-200 10 VB610 511.00 6SLL1 3207.00 8.75 S 400-600 15 VB6150 211.00 6SCL1 3207.00 8.75 S 800-1200 햸 161⁄4 F6162D 1366.00 LMD6, LMXD6, HLMD6, HLMXD6 SLM1D 3240.00 8.75 S MD6, MXD6, HMD6, HMXD6, CMD6 SMND 3847.00 10. S SMD6, SHMD6, SCMD6 SSMND 4097.00 10. S NM, HM, LM, (VL Breaker) MG1D 3317.00 8.75 S ND6, NXD6, HND6, HNXD6, CND6 SMND SND6, SHND6, SCND6 SSMND 4097.00 10. S NN, HN, LN, (VL Breaker) NG1D 3939.00 10 S 3847.00 10. S Note: D = Denotes double branch or twin mounting S = Denotes single mount Disconnect Device Strap Kit Catalog Number List Price $ NGB SMMNGMK 135.00 HEG SMMHEMK 135.00 BQ, BQH, HBQ SMMBQMK 135.00 QJ2, QJH2, QJ2-H SMMQJMK 135.00 ED4, HED4 SMMEDMK 135.00 FD6, HFD6 SMMFDMK 135.00 CED6 SMMCEMK 135.00 T-Fuse Pullout SMMTFMK 135.00 햲 Consult sales office for availability. strap kit includes front filler plate. 햳 Connecting 12-26 302.00 Blank Plates — Circuit Breaker and Vacu-Break 햲 Discount Schedule SWBD For use with Series 5 or 6 VB and CDP Panelboards, FC20, Class II, FCI, FCII, SB1, SB2, and SB3 Switchboards. Catalog Number Height (inches) Series 6 List Price $ 11⁄4 6FPB01 196.00 21⁄2 6FPB02 224.00 33⁄4 6FPB03 224.00 5 6FPB05 224.00 10 6FPB10 302.00 Note: Price breakers from circuit breaker section of this catalog. Connecting Kits For use with SMM and SMD metering switchboards.햶 햹 For inches / millimeters conversion, see conversion table in Application Data section. List Price $ Replacement Meter Socket Kits 햶 햷 For use with SMM and SMD metering switchboards. Type Strap Kit Catalog Number List Price $ 1-Phase MSK2001 281.00 3-Phase MSK2003 385.00 햴 10" plate accommodates 18 BQ or HBQ 1-pole breakers. consist of all necessary mounting hardware, less disconnect device and cable. 햶 Siemens meter sockets used in SMM switchboards built after 1/91. 햵 Kits Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햷 Siemens Type WMS263 Meter Sockets are rated 200A Continuous Duty. Type HCP. 햹 Special order component supplied by apparatus factory. Contact Sales for availability. 햸 Discount Schedule SWBD 13SPEEDFAX TM 2007-2008 Switchgear Contents Medium Voltage Equipment 5-15 kV GM-SG and 38 kV GM38 Metal-Clad Switchgear 13-2 – 13-23 13-2 – 13-15 38 kV GIS Metal-Clad Switchgear 13-16 5-15-27 kV SIMOSEC Metal-Enclosed Load Interrupter Switchgear 13-17 MV Controllers (MVC) up to 7.2 kV Reduced Voltage Starters (FVNR, RVPR, RVAT) Solid State Reduced Voltage Starter (SSRV) 13-19 13-20 – 13-22 SARRACS Remote Breaker Racking Remote Circuit Breaker Controller System Power Switching Centers 13-23 13-23 13-24 Standard Design Air Insulated 13-24 5-15-27 kV SIMOSEC Metal-Enclosed Load Interrupter Switchgear 13-24 Protective Relays & SCADA Systems SCADA/Substation Automation SIPROTEC Protective Relays Replacement Breakers & Retrofit Products 13-25 – 13-30 13-25 13-26 – 13-30 13-31 – 13-32 Medium Voltage Replacement Circuit Breakers 13-31 Safety Racking Solutions 13-32 Field Services Start-up/Commissioning/Engineer-by-the-Day Services 13-33 – 13-36 13-33 – 13-34 Power System Studies 13-35 Arc Flash Study 13-36 Secondary Unit Substations Overview 13-37 – 13-41 13-37 Transformers (See Transformer Section 7) Dry Type 13-38 Liquid Filled Type 13-39 Transition Sections 13-40 Switchboard Secondary (See Switchboard Section 12) 13-41 Switchgear Secondary (See Low Voltage Switchgear) 13-41 Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear Options 13-42 – 13-53 13-42 – 13-48 13-45 Type WL Circuit Breakers Rogowski Coil CT Technology Electronic Trip Units WL Communication Overview Arc Flash Solutions 13-49 13-49 – 13-50 13-51 13-52 – 13-53 All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness hereof is not guaranteed. Since conditions of use are outside our control, the user should determine the suitability of the product for its intended use and assumes all risk and liability whatsoever in connection herewith. Residential Commercial Industrial SWITCHGEAR Arc Flash Solutions 13 Motor Protection Options 13-18 – 13-19 Medium Voltage Equipment SWITCHGEAR 13 5-15 kV GM-SG and 38 kV GM38 Metal-Clad Switchgear Overview Features Siemens 5, 7, 15 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear is of the metal-clad type as covered by ANSI standard C37.20.2. All parts are completely enclosed within grounded metal barriers. Circuit breakers are the horizontal drawout type. Secondary control devices and primary circuits are isolated from each other by shutters or barriers. Primary circuits of different potential are also separated by barriers. All primary bus work and joints are completely encased with insulation material to suit the voltage class of the equipment. Each vertical section may contain a main bus bar section and two compartments for auxiliary devices and / or circuit breakers, with primary and secondary disconnects, instrument transformers, instruments and relays, secondary wiring and other necessary components. The switchgear is designed so that additional vertical sections with circuit breakers and / or auxiliary compartments may be added in the future. The space saving potential of the 5-15kV type GM-SG cubicle and GMSG circuit breaker designs allows up to two drawout elements to be furnished in a single vertical section. The units can be furnished with two 2000 ampere circuit breakers in one unit. For 3000 ampere self-cooled or 4000 ampere fan-cooled circuit breakers, one rollout auxiliary can be located in the lower cell, with the circuit breaker in the upper cell; or the cell can be left blank, with the circuit breaker located in the lower cell. Floor Rollout Circuit breakers in the lower cell can be rolled out directly on the floor in front of the unit, without a handling device, lift truck, or hoist for indoor and Shelter-Clad (walk-in) outdoor installations. A lift truck accessory is optionally available for handling circuit breakers in the upper cell of the 5-15kV GM-SG switchgear, or in non-walk-in outdoor enclosures, or for installations of switchgear on a raised “housekeeping” pad. Closed Door Racking The cell mounted racking mechanism may be operated with the cell door open or closed, through a small opening in the lower section of each door. For racking, a manual drive crank or an optional electric motor drive may be used. Automatic Shutters Automatically operated grounded steel shutters are included to allow or block access to the stationary primary disconnects. The shutters are designed to remain closed until they are forced open by insertion of the circuit breaker. This design maximizes protection for maintenance personnel, as compared to racking mechanism operated shutters, which could be opened with the circuit breaker out of the cell thereby exposing personnel to energized components. White Interior Device Panels in Front Compartments Standard 5 through 15kV Available in TwoHigh Design 38kV Available in One-High Design Only General Tested to ANSI Standards Siemens switchgear is tested to meet the requirements of ANSI standards. A complete design test program including short circuit interruption, load current switching, continuous current, mechanical endurance, close and latch current, short time and momentary withstand, impulse withstand, and the other tests required by the standards has been successfully completed. Certified test data can be furnished to customers upon request. These tests encompass the complete equipment design, including both the switchgear structure and the circuit breaker removable element. 4000A Rating (5–15kV) Designs are available to 3000A selfcooled, and 4000A fan cooled. 3000A Rating (38kV) Designs are available to 2000A selfcooled and 3000A fan cooled. UL listing UL listings to ANSI C37.54/C37.55 standards is optionally available. cUL Available 50kA Interrupting Rating Available at up to 15kV Siemens Relays, see Relaying section on page 13-25 For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Medium Voltage Equipment GM-SG Overview General Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-3 SWITCHGEAR Maintenance Intervals If applied under ANSl “usual service” conditions, maintenance of the circuit breaker mechanism is only needed at ten year intervals. Maintenance of the switchgear cubicle is recommended at five year intervals, and primarily consists of cleaning insulation. Floor Rollout No lift truck or dolly is needed to insert or remove circuit breakers in the lower cell of switchgear located at floor level. For indoor switchgear located on a raised “housekeeping” pad or for outdoor non-walk-in switchgear, a lift truck is required to handle circuit breakers. "Universal" Spare Breaker (up to 50kA) The physical configuration and interlock logic allow the use of a single circuit breaker to serve as a “universal” spare breaker at an installation site for up to 50kA. The interlock logic checks the principal rating characteristics (continuous current, maximum voltage, and interrupting current), and allows a circuit breaker to be inserted in any circuit breaker cell, provided that the circuit breaker equals or exceeds the ratings required by the cell. Single Source Responsibility Single source responsibility is assured since the complete equipment is designed by Siemens and is manufactured and tested in a single facility. The vacuum circuit breakers are checked in the switchgear cells as part of production testing, and shipped in the switchgear to assure interchangeability and reduce the possibility of damage to circuit breakers in shipment. Full ANSI Design Background Full design integrity is assured. ANSl C37.09 and C37.20.2 require design tests on circuit breakers and structures together. The 3AH3 operator is produced in our global center of competence for circuit breakers in Berlin, and final assembly of both the drawout GMSG circuit breaker and the switchgear structures occurs in a single facility. Siemens controls the entire process, from design concept to production. Records are maintained to document compliance with ANSl standards. UL or C-UL Listing Available Where the arrangement of components allows, UL or C-UL Listing is available. Quality Systems Facilities involved with application, engineering, design and production are certified to ISO 9001 requirements. 13 Siemens GM-SG 5kV, 7.2kV and 15kV metal-clad power switchgear assemblies with horizontal drawout type GMSG vacuum circuit breakers take advantage of the latest developments in vacuum interrupter technology. Up to two circuit breakers can be stacked in a single vertical section, allowing significant space savings. The equipment meets or exceeds the latest standards of ANSI, IEEE, and NEMA. GM-SG switchgear is designed for use in industrial plants, commercial buildings, electric utility systems, cogeneration installations, and other electrical systems. It is commonly used for protection and switching of transformers, motors, generators, capacitors, buses, distribution feeder lines, and, in general, for protection of any medium voltage power circuit. Siemens experience gained in over 80 years of supplying metalclad switchgear in the U.S. has been captured in the GM-SG design. The objective has been to incorporate features designed to provide safety, while simplifying operation, maintenance, and minimizing installation cost. The switchgear structure and the drawout vacuum circuit breaker are an integrated design, with dielectric, thermal, and interruption integrity built directly into the basic design, not added as an afterthought. Siemens 3AH3 Operating Mechanism The GMSG circuit breaker uses the proven Siemens 3AH3 stored-energy operating mechanism. This operator is an evolution of the 3A family of operators first introduced in 1976. Over 60,000 3AH3 operating mechanisms have been produced since 1998. Faster Interruption Standard interrupting time is 5-cycles with an option available for 3-cycle interrupting time. Siemens Vacuum Interrupters The vacuum interrupters used in the GMSG circuit breaker are manufactured by Siemens and have been proven in thousands of installations since 1976. The chrome-copper contact design used in these interrupters assures low chopping levels, eliminating the need for surge protection on most circuits. Front Mounted Operating Mechanism The simple GMSG operating mechanism makes maintenance and inspection easy. The mechanism is located on the front of the circuit breaker, rather than underneath. Medium Voltage Equipment GM-SG Overview General Figure 1: GM-SG Switchgear 1200A or 2000A Circuit Breaker Section F A B G H SWITCHGEAR 13 C I D J A K H E A. Current transformers 2 per bushing standard accuracy B. Upper circuit breaker C. Isolated relay and instrument compartment D. Inter-unit wiring E. Lower circuit breaker F. Outgoing cable lugs (downfeed shown) G. Surge arresters H. Ground sensor CT I. Main bus bars J. Removable barrier K. Power cable duct Structural Flexibility Siemens GM-SG metal-clad switchgear provides enhanced flexibility in locating circuit breaker, auxiliary, and metering cells within the structure layout. Circuit breakers rated 1200A and 2000A may be located in upper or lower cell positions. Bus sectionalizing (tie) circuit breaker cells may be located on the upper or lower levels and are ordinarily located next to an auxiliary cell on the same level to accommodate transition bus work. 3000A circuit breakers can be located either in the bottom cell or the top cell of a vertical section. If the 3000A circuit breaker is located in the lower cell, the upper cell can be used for metering devices only. If the 3000A circuit breaker is in the upper cell, the lower cell may be used to house a set of drawout voltage transformers, or a drawout control power transformer, or rollout fuses for a remote control power transformer. The 3000A circuit breaker can be used for 4000A continuous current applications, with the addition of fan cooling equipment in the auxiliary cell above or below the circuit breaker. This application of fan cooling is well suited if loads above 3000A are infrequent, as for example, in the case of a fan-cooled rating on a power transformer. Each vertical section contains the main bus bar compartment plus a rear compartment for incoming and outgoing connections. The front portion of the vertical section contains 13-4 a central secondary device compartment, located between two cells for auxiliary devices and / or circuit breakers, including primary and secondary disconnects, instrument transformers, instruments and relays, secondary wiring, and other components as necessary. The switchgear is normally designed so that additional vertical sections may be added in the future. Enclosure Design The GM-SG design includes full ANSI/IEEE C37.20.2 MetalClad construction. This means complete enclosure of all live parts and separation of major portions of the circuit to retard the spread of faults to other compartments. Removable plates permit access to all compartments. The rear panels are individually removable to allow separate access either to downfeed or upfeed cable connections. The structure is constructed of bolted steel for better dimensional control than with welded designs. Sheet steel interunit barriers extend the full height and depth of each vertical section for isolating adjacent sections. The ground bus extends the entire length of the complete switchgear lineup, and to all circuit breaker cells. Circuit Breaker Interchangeability The GM-SG switchgear cubicle and the removable GMSG circuit breaker element are both built to master fixtures so circuit breakers of the same ratings are interchangeable with each other even if the circuit breaker is required for use with a cell with "provisions only" supplied years earlier. The GMSG circuit breaker is not interchangeable with the older designs. A circuit breaker of higher rating (up to 50kA) can be used in a cell of equal or lower rating, i.e., a 3000A 50kA 15kV circuit breaker can be used in a 1200A 25kA 15kV circuit breaker cell. Tested to ANSl/IEEE Standards Siemens GM-SG switchgear is tested to meet the requirements of ANSl/IEEE standards. A complete design test program, including short circuit interruption, load current switching, continuous current, mechanical endurance, close and latch current, short time and momentary withstand, impulse withstand, and the other tests required by the standards has been successfully completed. These tests encompass the complete equipment design, including both the switchgear structure and the circuit breaker removable element. Production tests in accordance with ANSl/IEEE standards are performed on every group of switchgear and on each circuit breaker. Certified copies of all test data can be furnished to customers upon request. The switchgear is not classified as arc-resistant switchgear, and has not been tested for resistance to internal arcing per IEEE C37.20.7. Qualification to seismic requirements of various codes (e.g., IBC-2006, UBC, IEEE 693, etc.) is available. Consult Siemens with detailed requirements. UL or C-UL Listing Available When specified, if the component configuration allows, the switchgear can be provided with the UL or C-UL (for use in Canada) listed label, indicating conformance to the requirements of ANSl C37.54 and ANSI C37.55. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Medium Voltage Equipment GM-SG Vacuum Circuit Breakers General Type GMSG Vacuum Circuit Breakers 5kV, 7.2kV and 15kV Side (barriers removed) Rear Figure 2: GMSG Circuit Breaker Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-5 SWITCHGEAR Front 13 Siemens Type GMSG circuit breakers are available in 25kA through 63kA* interrupting classes, or 250MVA through 1000MVA on the older “constant MVA” rating basis. Continuous current ratings include 1200A, 2000A, and 3000A self-cooled. 4000A is available using a 3000A circuit breaker together with forced-air (fan) cooling in the switchgear cubicle. *Consult factory for availability of 63kA Maintenance Features The GMSG circuit breakers incorporate many features designed to reduce and simplify maintenance, including: ▪ Virtually maintenance-free vacuum interrupter ▪ Ten year maintenance interval ▪ Floor rollout ▪ Front mounted operator ▪ Common operator family ▪ Simple outer-phase barriers ▪ “Universal” spare circuit breaker concept ▪ Non-sliding current transfer ▪ Rugged secondary disconnects Ten Year Maintenance Interval on GMSG Circuit Breaker When applied under mild conditions (ANSI “usual service” conditions), maintenance is only needed at ten year intervals on the circuit breaker. The maintenance interval for the switchgear cubicles is five years. Low Maintenance Requirements The interrupter is a sealed unit, so the only maintenance necessary is to clean off any contaminants and to check the vacuum integrity. The vacuum interrupters can be disconnected from the stored energy mechanism quickly, without tools, and vacuum integrity inspected by hand; alternatively, a simple hi-pot test can be used. Floor Rollout When located in the lower cell, the circuit breakers are arranged to rollout directly on the floor in front of the switchgear if the switchgear is not located on a “housekeeping” pad. No adapter, hoist, or lift truck is necessary. Mechanism Operation The mechanism is arranged to pre-store closing energy in the closing springs. The closing springs are selected so that they provide sufficient energy not only to close the circuit breaker safely into maximum "close and latch" currents, but also to pre-store the tripping energy necessary to open the circuit breaker. The closing springs can be manually charged during maintenance or in emergency conditions, but are normally charged electrically automatically after each closing operation. Interlocks The racking system prevents racking of a closed circuit breaker, and keeps the circuit breaker trip-free during racking. The racking mechanism can be padlocked to prevent unauthorized operation. Padlocks can also be applied to the racking mechanism to maintain the circuit breaker in the tripfree condition. Stored Energy Operator The GMSG circuit breaker utilizes the Siemens 3AH3 stored energy operator for long life, high reliability, and ease of maintenance. Parts used in the manufacture of the circuit breaker are precision tooled or produced on numerically controlled equipment. The circuit breaker design includes frequent use of inherent alignment techniques. Medium Voltage Equipment GM-SG Ratings Selection Table 1: Type GMSG Circuit Breaker Ratings (New “Constant kA” Ratings Basis) These ratings are in accordance with the following standards: ▪ ANSI/IEEE C37.04-1999 Standard Rating Structure for AC High-Voltage Circuit Breakers ▪ ANSI C37.06-2000 AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis - Preferred Ratings and Related Required Capabilities ▪ ANSI/IEEE C37.09-1999 Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis ▪ ANSI/IEEE C37.010-1999 Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis Circuit Breaker Type햲 Units Maximum Design Voltage (V)햳 kV rms 4.76 4.76 4.76 8.25 15.0 15.0 15.0 15.0 Voltage Range Factor (K)햴 — 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Power Frequency kV rms 19 19 19 36 36 36 36 36 Lightning Impulse (BIL) kV crest 60 60 60 95 95 95 95 95 Continuous햵 A rms 1200 2000 3000 4000FC 1200 2000 3000 4000FC 1200 2000 3000 4000FC 1200 2000 3000 4000FC 1200 2000 1200 2000 3000 4000FC 1200 2000 3000 4000FC 1200 2000 3000 4000FC Short-Circuit (I)햶햷 kA rms sym 40 50 63 40 25 40 50 63 Interrupting Time햸 ms cycles 83 5 83 5 83 5 83 5 83 5 83 5 83 5 83 5 Permissible Tripping Delay (Y) Sec 2 2 2 2 2 2 2 2 Max. Sym. Interrupting (I) kA rms sym 40 50 63 40 25 40 50 63 % dc Component % 47 47 47 47 47 47 47 47 Short-Time Current (I) (3 seconds) kA rms 40 50 63 40 25 40 50 63 Closing & Latching (Momentary) Asymmetrical (1.55 x I) kA rms 62 78 98 62 39 62 78 98 Closing & Latching (Momentary) Peak (2.6 x I) kA peak 104 130 164 104 65 104 130 164 SWITCHGEAR 13 Rated Values 5-GMSG40 xxxx-104 Withstand Voltage Levels 햲 햳 햴 5-GMSG50 xxxx-130 5-GMSG63햹 xxxx-164 7-GMSG40 xxxx-104 15-GMSG25 xxxx-65 15-GMSG40 xxxx-104 15-GMSG50 xxxx-130 15-GMSG63햹 xxxx-164 “xxxx” in type designation refers to the continuous current rating 1200, 2000, or 3000A, as appropriate. The 4000A fan-cooled rating is achieved using a 3000A circuit breaker, in combination with fan cooling as indicated in footnote 4. Maximum design voltage for which the circuit breaker is designed, and the upper limit for operation. K is listed for informational purposes only. For circuit breakers rated on a “constant kA basis”, the voltage range factor is 1.0. 13-6 햵 햶 햷 햸 햹 4000FC indicates that fan cooling is included in the switchgear structure for this rating. 4000A rating is not available in outdoor equipment. All values apply to polyphase and line-to-line faults. Standard duty cycle is O - 0.3s - CO - 3 min. - CO. Standard rated interrupting time is 5 cycles (83ms). Optional rated interrupting time of 3 cycles (50ms) is available. Consult factory for availability. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Medium Voltage Equipment GM-SG Ratings Selection Table 2: Type GMSG Circuit Breaker Control Data 햵 Control Voltages, ANSI C37.06 Range Nominal 햴 Trip Amperes햲 Charging Amperes햲햴 Run (Avg.)햲 Seconds 24 VDC 19 - 28 14 - 28 5.8 17 / — — — 36 - 56 28 - 56 2.9 11.4 / 30 8 10 125 VDC 100 - 140 70 - 140 1.0 4.8 / 7.4 4 10 250 VDC 200 - 280 140 - 280 0.5 2.1 / 4.2 2 10 120 VAC 104 - 127 104 - 127 0.9 208 - 254 208 - 254 0.4 Current at nominal voltage. Capacitor trip. Value preceding slash ( / ) is the current for the standard trip coil with standard rating interrupting time. Value following ( / ) is current for optional trip coil with 3-cycle interrupting time. — means this selection not available in this voltage. — 햳 6 10 — 햳 3 10 Table 5: Current Transformers햲 Ratio 60Hz Metering Accuracy at Burden B0.1 B0.5 B1.0 B2.0 Relay Class SWITCHGEAR 햵 Close Spring Charging Motor Amperes 13 햳 Trip Coil 48 VDC 240 VAC 햲 Close Coil Type MD Torroidal Standard Accuracy Table 3: Interrupting Capacity Auxiliary Switch Contacts햳 Type Switch Circuit Breaker TOC MOC 햲 햳 Continuous Current Amperes 10 15 20 Control Circuit Voltage 120 AC 10 240 AC 5 15 48 DC 10 / 30햲 10 15 125 DC 5 0.5 10 0.5 10 10 250 DC 3 0.2 5 2 contacts in series. All switch contacts are non-convertible. Table 4: Voltage Transformers Voltage Class Accuracy Class at 120V Sec. Ratio X, Y, Z 5kV 5kV 5kV 15kV 15kV 15kV 15kV 2400 / 120 4200 / 120 4800 / 120 7200 / 120 8400 / 120 12000 / 120 14400 / 120 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Z 1.2 1.2 1.2 0.3 0.3 0.3 0.3 ZZ — VA Thermal Rating 500 — 500 1.2 1.2 1.2 1.2 2.4햳 — — — C 15 150:5 0.6 2.4 — — C 20 200:5 0.6 1.2 — — C 25 250:5 0.6 1.2 2.4 — C 35 300:5 0.6 0.6 1.2 2.4 C 40 400:5 0.3 0.6 1.2 2.4 C 60 500:5 0.3 0.3 0.6 1.2 C 75 600:5햴 0.3 0.3 0.6 1.2 C100 800:5 0.3 0.3 0.6 0.6 C130 1000:5 0.3 0.3 0.3 0.3 C170 1200:5햴 0.3 0.3 0.3 0.3 C200 1500:5 0.3 0.3 0.3 0.3 C200 2000:5햴 0.3 0.3 0.3 0.3 C210 2500:5 0.3 0.3 0.3 0.3 C300 3000:5햴 0.3 0.3 0.3 0.3 C240 4000:5햴 0.3 0.3 0.3 0.3 C230 75:5 2.4햳 4.8 — — C 20 100:5 1.2 2.4 — — C 30 150:5 0.6 1.2 2.4 4.8 C 40 200:5 0.6 1.2 1.2 2.4 C 60 250:5 0.3 0.6 1.2 2.4 C 80 300:5 0.3 0.6 0.6 1.2 C100 400:5 0.3 0.3 0.6 0.6 C130 500:5 0.3 0.3 0.3 0.6 C160 600:5햴 0.3 0.3 0.3 0.3 C210 800:5 0.3 0.3 0.3 0.3 C270 1000:5 0.3 0.3 0.3 0.3 C340 1200:5햴 0.3 0.3 0.3 0.3 C425 1500:5 0.3 0.3 0.3 0.3 C510 2000:5햴 0.3 0.3 0.3 0.3 C460 2500:5 0.3 0.3 0.3 0.3 C580 3000:5햴 0.3 0.3 0.3 0.3 C660 4000:5햴 0.3 0.3 0.3 0.3 C460 Type MDD Torroidal Special Accuracy 500 — 100:5 1000 1000 1000 1000 햲 햳 햴 1-second through-current and momentary current are equal to the ratings of the associated circuit breakers. Exceeds ANSI C37.20.2 Accuracy Limit. Multi-ratio current transformers available. The accuracy ratings shown apply only to the full secondary winding. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-7 Medium Voltage Equipment GM-SG Dimensions Table 6: Cubicle Dimensions Per Vertical Section 햲햴 Dimensions in Inches (mm) SWITCHGEAR 13 Type Weight in lbs. (kg) Height Width Depth Drawout Aisle Indoor GM-SG 95.25 (2419) 36.0 (914) 98.5 (2502)햸 72.0 (1829) recommended햶 3300 (1497) Shelter-Clad Single-Aisle SGM-SG 114.75 (2915) 36.0 (914)햵 173.5 (4407)햷 72.0 (1829) included 5000 (2268) Shelter-Clad Common Aisle SGM-SG 114.75 (2915) 36.0 (914)햵 269.0 (6833)햷 72.0 (1829) included 8900 (4037) Aisle-Less Non-Walk-In OGM-SG 113.62 (2886) 36.0 (914)햵 101.9 (2588)햷 72.0 (1829) recommended햶 3950 (1792) Table 7: GMSG Vacuum Circuit Breaker Weight in lbs. (kg)햳햴 Circuit Breaker Type Continuous Current (A) 햲 햳 햴 햵 햶 햷 햸 햹 5-GMSG-40 5-GMSG-250 5-GMSG-50 5-GMSG-350 5-GMSG-63 7-GMSG-40 7-GMSG-500 15-GMSG-25 15-GMSG-500 15-GMSG-40 15-GMSG-750 15-GMSG-50 15-GMSG-1000 15-GMSG-63 1200 440 (200) 455 (206) 809 (368) 455 (206) 430 (195) 445 (202) 460 (209) 819 (372) 2000 650 (295) 665 (302) 819 (372) 665 (302) 640 (290) 670 (304) 675 (306) 829 (377) 3000 665 (302) 670 (304) 824 (375) 675 (306) — 675 (306) 680 (308) 834 (379) Weight does not include circuit breakers, add separately from table 7. Weight estimates are for circuit breaker only. Add 75 lbs (34 kg) if shipped separately packaged. Weight and dimensions are approximate. Add 6” (152 mm) to each end of lineup for aisle extension 12” (304 mm) total. 72” (1829 mm) aisle space recommended allows room for interchange of circuit breakers. Minimum aisle space required for handling circuit breaker with lift truck is 65” (1651 mm). Minimum aisle space required if all circuit breakers are at floor level is 54” (1372 mm). Add for roof overhang. Shelter-Clad Non-Walk-In Rear (cable side) 3.62” (92 mm) 3.62” (92 mm) Front (drawout side) 5.37” (136 mm) 1.5” (38 mm) If indoor switchgear is installed on a raised “housekeeping” pad, the pad must not extend further than 3” (75 mm) from the front of the switchgear to avoid interference with the use of the portable lift truck. Approximate circuit breaker dimensions in inches (mm) (W X D X H): Net 32” (813 mm) X 39” (991 mm) X 36” (914 mm) If packed for shipment separate from switchgear: 42” (1067 mm) X 47” (1194 mm) X 43” (1092 mm) 13-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Medium Voltage Equipment GM-SG Stacking Versatility Dimensions Auxiliary 1200A Circuit Breaker 1200A Circuit Breaker C 1200A Circuit Breaker 2000A Circuit Breaker Auxiliary A LV Panel A D LV Panel A A LV Panel LV Panel 1200A Circuit Breaker 2000A Circuit Breaker 1200A Circuit Breaker 13 LV Panel E Auxiliary B F B Auxiliary 2000A Circuit Breaker 2000A Circuit Breaker C Auxiliary LV Panel LV Panel 2000A Circuit Breaker 2000A Circuit Breaker A C Auxiliary D LV Panel Auxiliary B F D LV Panel Auxiliary Vented 햶 3000A 햶 Circuit Breaker E A LV Panel LV Panel Auxiliary B 3000A 햶 Circuit Breaker Vented 햶 D B Auxiliary Vented 햶 C A B SWITCHGEAR Auxiliary 1200A Circuit Breaker E Auxiliary B E Auxiliary F F Figure 3: GM-SG Stacking Versatility Main bus sizes 1200A, 2000A, 3000A or 4000A (self-cooled). No rollout auxiliaries allowed in upper cell (C or D) if lower cell (B) has 3000A circuit breaker. If 3000A circuit breaker is located in upper cell (A), one rollout auxiliary may be located in lower cell F. 햴 Auxiliary cells (C, D, E, or F) may each contain 1 rollout (except as indicated in notes 2 and 5). 햵 Fuse rollout for stationary control power transformer must be located in lower rollout cell F, if CPT is located in rear or is remote. If CPT is located in lower auxiliary cell (E and F), fuse rollout is located in upper auxiliary cell. 햲 햳 For fan cooled 4000A rating, circuit breaker (3000A self-cooled, 4000A fancooled) may be located in upper cell (A) with fan cooling in cell E, or may be located in lower cell (B) with fan cooling in cells C and D. 햷 Stacking arrangements are available as shown. Total circuit breaker loading in a vertical unit may not exceed main bus rating. Consult Siemens for specific application assistance regarding total load limits in each unit, or refer to ANSI/IEEE C37.20.2. 햶 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-9 Medium Voltage Equipment SWITCHGEAR 13 GM-SG Accessories Standard Accessories Include: ▪ Manual racking crank ▪ Spring charging crank ▪ Drawout extension rails (facilitate handling of circuit breakers in upper cell) ▪ Lifting sling (for circuit breakers above floor level) ▪ Split plug jumper (standard unless test cabinet is furnished) ▪ Contact lubricant ▪ Touch up paint Optional Accessories Include: ▪ Circuit breaker lift device ▪ Test cabinet (in place of split plug jumper) ▪ Test plugs (if required by devices) ▪ Electric racking motor assembly (to enable racking while operator is at a distance from the switchgear) ▪ Manual or electrical ground and test device Test provisions, either a split plug jumper or a test cabinet, are available for testing the circuit breaker outside its cubicle. The split plug jumper is used to bridge the secondary disconnects with a flexible cable, so the circuit breaker may be electrically closed and tripped with the control switch on the instrument panel while the circuit breaker is outside of its compartment. The test cabinet, including a control switch is used for closing and tripping the circuit breaker at a location remote from the switchgear. Manual Ground and Test Device This is a drawout element that can be inserted into a circuit breaker cell. It opens the shutters, connects to the cell primary disconnecting contacts, and so provides a means to make the primary disconnect stabs available for testing. It is suitable for high potential testing of outgoing circuits of the switchgear main bus, or for phase sequence checking. It also provides a means to connect temporary grounds to de-energized circuits for maintenance purposes. The manual ground and test incorporates three-position singlepole switches (upper stabs to ground, neutral, and lower stabs to ground), eliminating the need for user-furnished ground cables. The switches are hook-stick operatable and are rated for the full momentary and short-time ratings of the associated switchgear. User-furnished grounding cables and commercially available ground clamps seldom have ratings equal to those of the switchgear. General Electrical Ground and Test Device An electrical ground and test device includes a power operated switch (derived from a GMSG circuit breaker) arranged to allow grounding one set of disconnect stabs. Two devices, one each for the upper and lower stabs, are required if grounding is desired to either side of the unit. The device also provides a means of access to the primary circuits for high potential tests or for phase sequence checking. These devices are able to close and latch against short circuit currents corresponding to the ratings of the equipment. Due to the unique requirements frequently involved in such devices, all applications of electrically operated ground and test devices should be referred to Siemens for review. Note: Due to the special nature of ground and test devices, each user must develop definitive operating procedures for incorporating safe operating practices. Only qualified personnel should be allowed to use ground and test devices. Figure 4: Accessory Cabinet 13-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Medium Voltage Equipment GM-SG Dimensions Figure 5: Switchgear End Views 13 SWITCHGEAR Type GM-SG Indoor Switchgear Type OGM-SG Non-walk-in Outdoor Switchgear Type SGM-SG Shelter-clad Single Aisle Outdoor Switchgear Type SGM-SG Shelter-clad Common Aisle Outdoor Switchgear Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-11 Medium Voltage Equipment SWITCHGEAR 13 38 kV GM38 Metal-Clad Switchgear General/Specifications ▪ Highly reliable vacuum interrupters – MTTF over 42,500 years ▪ Up to 50 full-fault interruptions ▪ Meets or exceeds the latest ANSI, IEEE and NEMA standards ▪ Universal spare circuit breaker ▪ Interlock permits insertion of higher rating vacuum circuit breaker into lower rated cell but not vice-versa ▪ Front accessible circuit breaker operating mechanism for ease of maintenance ▪ Closed door racking ▪ Floor rollout circuit breaker in lower cell without a dolly Drawout Indoor Switchgear ▪ Horizontal drawout type 38-3AH vacuum circuit breaker ▪ Uses the latest developments in vacuum interrupter technology Ratings Circuit Breaker Type Table 8 Type 38-3AH Circuit Breaker Ratings 38-3AH- 38-3AH- 38-3AHMeasured Parameter 40 1500 31 38.0 38.0 kV 38.0 General Nominal Voltage Class Nominal 3-Phase MVA Class — MVA 1500 — 38.0 Max 38.0 E kV RMS 38.0 Rated Rated Values Voltage 1.0 Voltage Range Factor 1.0 1.65 K 80 Low Frequency kV RMS 80 80 Insulation Rated Withstand Levels Test Voltage 150 Impulse kV Crest 150 150 1200 1200 1200 Amperes 2000 2000 2000 Continuous 3000FC 3000FC 3000FC Rated Short circuit (at rated max. kV) 31.5 40 I kA RMS 21 Current 5 5 5 Interrupting Time Cycles 2 2 Permissible Tripping Delay Y Sec. 2 38 38 23 Rated Max. Voltage Divided by K E/K kV RMS Related Required Max. Sym. Interrupting K Times Rated kA RMS 31.5 40 35 Current CapaShort Circuit 3-Sec. Short Time bilities 31.5 40 kA RMS 35 Current KI Current Carrying Closing and 50 62 kA RMS 56 Latching 85 104 kA Crest 95 (Momentary) Type 38-3AH-1500 ratings are in accord with ANSI C37.06-1987. Type 38-3AH-31 and 38-3AH-40 ratings conform to C37.06-2000 ratings. Maximum voltage for which the circuit breaker is designed and the upper limit for operation. K is the ratio of rated maximum voltage to the lower limit of the range of operating voltage in which the required symmetrical and asymmetrical interrupting capabilities vary in inverse proportion to the operating voltage. 3000 ampere ratings are achieved using forced air cooling in the switchgear cubicle. To obtain the required symmetrical interrupting capability of a circuit breaker at an operating voltage between 1/K times rated maximum voltage and rated maximum voltage, the following formula shall be used. Rated Maximum Voltage Required Symmetrical Interrupting Capacity = Rated Short Circuit Current × Operating Voltage For operating voltages below 1/K times rated maximum voltage, the required symmetrical interrupting capability of the circuit breaker shall be equal to K times rated short circuit current. With the limitations stated in 5.10 of ANSI Standard C37.04-1979, all values apply for polyphase and line-to-line faults. For single phase-to-ground faults, the specific conditions stated in 5.10.2.3 of ANSI Standard C37.04-1979 apply. Current values in this row are not to be exceeded even for voltages below 1/K times rated maximum voltage. For voltages between rated maximum voltage and 1/K times rated maximum voltage, follow 5 above. Current values in this row are independent of operating voltage up to and including rated maximum voltage. Included for reference only—not listed in ANSI C37.06. Table 9 Type 38-3AH Circuit Breaker Control Data Control Voltages, ANSI C37.06 Table 10 Range Nominal Close Trip 38–56 28–56 48 VDC 100–140 70–140 125 VDC 200–280 140–280 250 VDC 104–127 — 120 VAC 208–254 — 240 VAC Current 13-12 Coil Amperes Close 2.1 1.0 0.5 0.9 0.4 Trip 20 5.4 2.1 — — Spring Charging Motor Amperes Charging Run (Avg.) Inrush (Peak) Seconds 8 25 10 4 18 10 2 10 10 6 — 10 3 — 10 at nominal voltage. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ▪ Visible secondary disconnect ▪ One high construction ▪ Pair with Siemens relays to match any application Table 10 Interrupting Capacity Auxiliary Switch Contacts Circuit Interrupting Capacity in Amperes Type Switch Cont. Current Amperes Non-inductive Breaker 10 TOC 15 MOC 20 Inductive Breaker 10 TOC 15 MOC 20 Table 11 Control Circuit Voltage 120 240 48 125 250 AC AC DC DC DC 10 15 15 5 10 10 10 0.5 10 9.6 0.5 10 4.8 0.2 5 6 15 15 3 10 10 10 6 0.5 0.5 10 10 3 0.2 5 Current Transformers 60 Hz Metering Accuracy at Burden Ratio B0.1 B0.5 B1.0 B2.0 Type MD38 Torroidal Standard Accuracy 100:5 2.4 — — — 150:5 0.6 2.4 — — 200:5 0.6 1.2 — — 250:5 0.6 1.2 2.4 — 300:5 0.6 1.2 1.2 2.4 400:5 0.3 0.6 1.2 1.2 500:5 0.3 0.3 0.6 1.2 600:5 햴 0.3 0.3 0.6 1.2 800:5 0.3 0.3 0.6 0.6 1000:5 0.3 0.3 0.3 0.3 1200:5 햴 0.3 0.3 0.3 0.3 1500:5 0.3 0.3 0.3 0.3 햴 2000:5 0.3 0.3 0.3 0.3 2500:5 0.3 0.3 0.3 0.3 3000:5 햴 0.3 0.3 0.3 0.3 Type MDD38 High Accuracy 75:.5 2.4 4.8 — — 100:5 2.4 4.8 — — 150:5 1.2 2.4 4.8 4.8 200:5 0.6 1.2 2.4 4.8 250:5 0.6 1.2 1.2 2.4 300:5 0.3 0.6 1.2 2.4 400:5 0.3 0.6 0.6 1.2 500:5 0.3 0.3 0.6 0.6 600:5 햴 0.3 0.3 0.6 0.6 800:5 0.3 0.3 0.3 0.3 1000:5 0.3 0.3 0.3 0.3 1200:5 햴 0.3 0.3 0.3 0.3 1500:5 0.3 0.3 0.3 0.3 햴 2000:5 0.3 0.3 0.3 0.3 2500:5 0.3 0.3 0.3 0.3 3000:5 햴 0.3 0.3 0.3 0.3 Relay Class C 10 C 20 C 25 C 35 C 40 C 60 C 75 C100 C130 C170 C200 C180 C210 C300 C300 C 15 C 20 C 35 C 50 C 70 C 90 C120 C150 C200 C250 C300 C400 C440 C450 C550 C700 1-second through-current and momentary current are equal to the ratings of the associated circuit breakers. Exceeds ANSI C37.20.2 Accuracy Limit. 햴 Multi-ratio current transformers available. The accuracy ratings shown apply only to the full secondary winding. Table 12 Voltage Transformers Volt. Class Ratio 38kV 1 Bushing 20125:115 24000:120 38kV 2 Bushing 27600:115 34500:115 Accuracy Class at 120V W,X,Y,Z ZZ VA Thermal Rating (55°C Amb) 0.3 1.2 1000 0.3 1.2 1000 Medium Voltage Equipment 38 kV GM38 Metal-Clad Switchgear Dimensions Enclosure Dimensions Table 13 Cubicle Dimensions-Per Vertical Section Table 14 38-3AH Circuit Breaker Weights in lbs. (kg) Type Indoor Shelter-Clad Single-Aisle GM38 Weight in lbs. (kg) 5000 (2273) SGM38 6400 (2909) 48 (1219)/ 132.5 (3366) 96 (2438) Included Shelter-Clad Common-Aisle SGM38 11700 (5318) 48 (1219)/ 132.5 (3366) 96 (2438) Included Aisle-Less Non-Walk-In OGM38 5800 (2636) 48 (1219) 130.5 (3315) 96 (2438) Recommended Dimensions in inches (mm) Width Depth 48 (1219) 110 (2794) Drawout Aisle 96 (2438) Recommended / Add Add for roof overhang Rear (Cable Side) Front Non-Walk-in 3.875 in. (98 mm) 6.875 in. (175 mm) 38-3AH-40 850 (387) 950 (432) 1050 (478) Shelter-Clad 3.875 in. (98 mm) 1.5 in. (38 mm) 13 6 in. (152 mm) to each end of lineup for aisle extension, 12 in. (305 mm) total. Cont. Current Circuit Breaker Type Amps 38-3AH-1500 38-3AH-31 800 (364) 800 (364) 1200 2000 900 (409) 900 (409) 3000 1000 (455) 1000 (455) SWITCHGEAR End View of Indoor Switchgear End View of Single Aisle Switchgear Type GM38 Type SGM38 End View of Aisle-Less Outdoor Switchgear End View of Common Aisle Switchgear (Non Walk-In) Type OGM38 Type SGM38 For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-13 Medium Voltage Equipment 38 kV GM38 Metal-Clad Switchgear Dimensions SWITCHGEAR 13 Floor Plans Indoor GM38 Switchgear Outdoor SGM38 Shelter-Clad Walk-In Single Aisle Switchgear Recommended location of conduits for power cables, top or bottom. Recommended location of secondary leads, top or bottom. Customer conduit not to extend more than 1 in. (25 mm) above floor line. Allow 6 in. (152 mm) clearance for lift truck on each end. Floor must be level 80 in. (2032 mm) in front of switchgear to allow proper operation of lift truck. Outdoor OGM38 Non Walk-in Switchgear Outdoor SGM38 Shelter-Clad Walk-In Common-Aisle Switchgear Table 15 38kV Switchgear Floor Plan Detail Dimensions in inches (mm) A B 130.0 (3302) 48.0 40.0 42.5 (1219) (1016) (1080) 13-14 C D E F G H J K 22.0 (559) 4.0 (102) 7.5 (191) 3.5 (89) 4.25 (108) 43.75 45.88 (1111) (1165) L M N O P Q R S 0.12 (3) 43.12 (1095) 2.82 (72) 43.75 (1111) 2.13 (54) 1.16 (29) 45.84 87.06 126.91 6.0 (1164) (2211) (3224) (152) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog T U V W X 47.5 96.0 (1207) (2438) Medium Voltage Equipment 38 kV GM38 Metal-Clad Switchgear Dimensions Side Views — 1200, 2000, 3000A Breakers / Auxiliary 13 VT Auxiliary / 1200A or 2000A Breaker (Downfeed Cables) Auxiliary / 1200A or 2000A Breaker CPT Fuse Truck / Stationary 3쏗 CPT (Upfeed Cables) Auxiliary / Bus Tie Breaker SWITCHGEAR Auxiliary / 1200A-3000A Breaker (No drawout auxiliaries in upper cell for 3000A breaker) Auxiliary / Feeder Breaker (Adjacent to right side of tie breaker section) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-15 Medium Voltage Equipment SWITCHGEAR 13 38 kV GIS Metal-Clad Switchgear General/Specifications size of conventional air insulated switchgear. MV Vacuum Interrupter GIS The 8DA and 8DB – up to 38kV, 2500A, 40kA, 200kV BIL. ▪ Inherently arc-resistant ▪ Significantly reduced P.P.E. needs ▪ Compact – 80% smaller than air insulated switchgear ▪ 20 year internal maintenance cycle ▪ Meets IEEE and IEC standards ▪ UL or C-UL Listing available ▪ Single phase design eliminates phaseto-phase faults ▪ Meets NEC visible disconnect requirement ▪ Well suited for contaminated environments ▪ Pair with Siemens Protective Relays to match any application GIS Types 8DA10 and 8DB10 Medium Voltage Gas-Insulated Switchgear are gas insulated, vacuum circuit breaker designs with a voltage range of 4.16kV to 38kV. Lightning impulse withstand voltage ratings up to 200kV BIL and interrupting ratings up to 40kA are available. The 8DA10 and 8DB10 Medium Voltage Gas-Insulated Switchgear designs feature fixed-mounted vacuum circuit breakers, connectable to the main bus through three-position (closed-openready to ground) switches. The position of the switches is externally observable from the front of the unit using a convenient camera system. Medium Voltage Gas-Insulated Switchgear is suitable for systems where small size, arc resistance, environmental immunity, or reduced maintenance needs are important. Depending upon the voltage rating, Medium Voltage Gas-Insulated Switchgear is approximately 1/5 the GIS Specification Sheet Rated Values 8DA10 3-pole / 8DB10 3-pole Voltage Frequency Short-dur. power-frequency withstand voltage Lightning impulse withstand voltage Short-circuit breaking current Short-time withstand current, 3s Short-circuit making current (peak) Peak withstand current Normal current of busbar Normal current of feeders Max. kV kV kV kV 15 60 Hz 36 95 up to 40kA up to 40kA up to 104kA up to 104kA up to 4000A up to 2500A 27 60 Hz 60 125 up to 40kA up to 40kA up to 104kA up to 104kA up to 4000A up to 2500A 38 60 Hz 80 170; 200* up to 40kA up to 40kA up to 104kA up to 104kA up to 4000A up to 2500A * On request. Consult factory 8DB Dimensions 8DA Dimensions Bus1 Bus2 34" 34" 93" 73" 83" 15" 29" 15" 11" 13" 64" 13-16 29" 24" 24" Front view 93" Side view 105" Front view Side view Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 11" 13" Medium Voltage Equipment 5–15–27 kV SIMOSEC Metal-Enclosed Load Interrupter Switchgear SIMOSEC Medium voltage metal-enclosed load interrupter indoor switchgear up to 27.6kV. ▪ Fuses and outgoing cables front accessible ▪ Standard viewing window for visible verification of isolating distance ▪ Standard capacitive voltage presence indicator ▪ Integrated mechanical interlocking ▪ Animated mimic diagram ▪ Main bus at top or bottom to suit application ▪ Configurations: individual feeder switches, transformer primary switches & switch lineups ▪ Ideal for utility, construction & industrial applications ▪ Over 20 years field experience and more than 350,000 switch-disconnector units installed SWITCHGEAR Fused Switch FS Cable Switch CS 13 Extremely compact footprint Meets ANSI / IEEE C37.20.3 UL or C-uL listing available Seismic up to Zone 4 (optional) High switching capacity – 100 operations @ 600A ▪ Gas insulated three-position switchdisconnector, hermetically sealed for life inside the stainless steel vessel ▪ Switch-disconnector combines the function of a load interrupter switch (with CLOSED-OPEN indication) and a grounding switch (with OPENGROUND indication) ▪ HV HRC fuses and cable terminations accessible only if the feeder grounding switch is in the grounded position ▪ ▪ ▪ ▪ ▪ General/Specifications Metering MT Cable Connection CC SIMOSEC Specification Sheet Dimensions Cable Switch CS Single cable or fuse Two cables or double-barrel fuse 3 Width depends on equipment arrangement 1 Width 1 14.8" (375mm) 2 2 19.7" (500mm) Depth Height Fused Switch FS 1 14.8" (375mm) 2 19.7" (500mm) Metering MT 3 19.7" (500mm) 3 29.5" (750mm) Cable Connection CC 1 14.8" (375mm) 2 19.7" (500mm) 48.4" (1230mm) 88.6 - 100.4" (2250 - 2850mm) depending on arrangement Ratings Rated voltage Rated frequency Rated short-duration power-frequency withstand voltage Rated lightning impulse withstand voltage (BIL) Rated short-time withstand current tk = rated duration of short Maximum fused continuous current (not fuse E rating) Up to 5kV 50 / 60 19kV 60kV 8.25kV & 15kV 50 / 60 36kV 95kV 27.6kV 50 / 60 60kV 125kV 2 Sec Up to 25kA Up to 25kA Up to 20kA Single fuse FS-1 Double fuse FS-2 Triple fuse FS-3 325A 575A 600A 600A, 1200A 600A 600A 165A 305A 430A 600A, 1200A 600A 600A 65A 117A 156A 600A, 1200A 600A 600A Main bus continuous Switch-disconnector Capacitive voltage indicator Continuous Interrupting Cable discharge switch (1.6kA 1-sec) (optional) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-17 Medium Voltage Equipment SWITCHGEAR 13 MV Controllers (MVC) up to 7.2 kV General The design and manufacture of the Series 81000™ meduim voltage controller unit is based on our experience as a leading manufacturer of motors worldwide. The benefits of this experience result in control scheme flexibility and increased safety, while simplifying operations, maintenance, and minimizing installation costs. Typical applications include: ▪ Squirrel-Cage Induction Motors (nonreversing, reversing, and multi-speed) ▪ Reduced Voltage Starters (autotransformer reactor or solid-state type) ▪ Synchronous motors (brush or brushless type) ▪ Wound Rotor Motors — with or without secondary control ▪ Transformer Feeders ▪ Capacitor Bank Feeders ▪ Power Bus Feeders (Tie) The utilization voltage range for the controllers is 2300 through 7200 volts AC. The Siemens Series 81000 medium voltage controller allows the user to combine vacuum contactors, latched contactors and load break switches in one lineup. The user can also connect directly to Siemens GM-SG Medium Voltage switchgear without additional transition sections. This provides extreme flexibility in systems design. Stationary Controllers: ▪ Full Voltage (FVNR) ▪ Reduced Voltage Primary Reactor (RVPR) ▪ Reduced Voltage Autotransformer (RVAT) Load Break Switches (LBS) Drawout Controllers: ▪ Full Voltage (FVNR) ▪ Reduced Voltage Primary Reactor (RVPR) ▪ Reduced Voltage Autotransformer (RVAT) ▪ Reduced Voltage Solid State (SSRV) ▪ Brushless Synchronous (BL-SYNCH) ▪ Brushtype Synchronous (BT-SYNCH) ▪ Two Speed Two Winding (2S2W) ▪ Two Speed One Winding (2S1W) ▪ Wound Rotor (WR) ▪ Reversing General E2 (Fused) Contactors — To meet interrupting capability required for NEMA Class E2 controllers, the 97H3 and 96H6 contactors are provided with primary current limiting fuses in all three phases. The resulting interrupting ratings are shown in the Table 17. Drawout Stationary Table 16 Controllers and Load Break Switches Selection Table Maximum Motor Size Load Break Switch (LBS) Table 17 Controller Type 2.3kV 4.16kV 6.9kV 13.8kV Stationary to 1500HP to 2500HP to 4000HP — Drawout to 3000HP to 5500HP to 4000HP — SSRV to 3000HP to 5500HP to 4000HP to 5500HP 600A Fused Unfused Fused Unfused — Unfused — — 1200A Fused Unfused Fused Unfused — Unfused — — Series 81000 Ratings Enclosed Continuous Ampere Rating Unfused Class E1 Fused Class E2 Motor Horsepower Rating (3 Phase) Maximum Synchronous InducMotor Motors tion Fuse 0.8 PF 1.0 PF Motors Rating 360 720 360 720 360 720 360 5kA 10kA 5kA 10kA 5kA 10kA 7.2kA 200 MVA 200 MVA 350 MVA 350 MVA 400 MVA 400 MVA 570 MVA 1500 3000 2500 5500 2500 5500 4000 Interrupting Capacity System Voltage 2300 2300 4000 4000 4600 4600 1750 3500 3000 6000 3000 6000 5000 1500 3000 2500 5500 2500 5500 4000 24R 57X 24R 57X 24R 57X 24R Transformer Loads Maximum 3-Phase kVA Maximum Fuse Rating 1500 2000 2500 3500 2500 4000 1500 450E 600E 450E 600E 450E 600E 200E Nominal motor voltage 6600V. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-18 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Medium Voltage Equipment MV Controllers (MVC) up to 7.2 kV General Stationary The Siemens Series 81000 MVC is also offered in a stationary contactor design. The one high stationary starters can be configured in a reduced height (75") and reduced width (24") stand-alone enclosure facilitating a smaller footprint and reduced shipping cost. Main and Vertical Bus Construction (shown with optional insulation) Series 81000 Bus Ratings Continuous Type Bus Amperes Main 600 Horizontal 1000 1200 1000 1200 2000 3000 360 Vertical 540 720 600 Ground Conductor Size in Inches (mm) 0.25 (6) x 3.0 (76) 0.375 (10) x 3.0 (76) 0.50 (13) x 3.0 (76) 0.25 (6) x 3.0 (76) 0.375 (10) x 3.0 (76) 2 x 0.375 (10) x 3.0 (76) 3 x 0.50 (13) x 3.0 (76) 0.25 x (6) x 1.0 (25) 0.25 (6) x 1.5 (38) 0.50 (13) x 2.0 (51) 0.25 (6) x 2.0 (51) Conductor Material Aluminum Copper Solid State Reduced Voltage Standard Adjustment Capabilities ▪ Soft start and stop ▪ Voltage and current ramp Starting Methods (settable) ▪ Current limit and dual ramp ▪ Learned acceleration curve or user defined (custom) acceleration curve ▪ Kick start and jog Optional Features ▪ Zero sequence ground fault protection ▪ Profibus communications Flexibility ▪ Available in lineups with up to 3000A main bus directly connected with MetalClad Switchgear, Load Interrupter Switches, or other Class E2 Controllers Safety ▪ Full drawout construction means power fuse changes are done outside of the enclosure Reliability ▪ Made under ISO 9001 Quality System standards Dependability ▪ Series 81000 Controllers have been in production for over 20 years UL Listed Current Density (Amps/in2) 800 889 800 1333 1067 889 667 1440 1440 720 1200 3000A bus must be located on top of unit. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-19 SWITCHGEAR Table 18 Soft Start Advantages ▪ Minimize system maintenance and repair ▪ Reduce system downtime ▪ Increase productivity ▪ Minimize mechanical wear and tear ▪ Reduce inrush currents ▪ Reduce motor torque for prolonged motor life Standard Features ▪ Drawout main fused contactor (360A) ▪ Drawout main fuses with fixed-mounted main contactor (720A) ▪ Bypass contactor ▪ Heavy duty soft start module ▪ 125% continuous duty rating (on soft start module only) ▪ Digital microprocessor control with nonvolatile memory ▪ Fiber optic isolation ▪ Advanced electronic motor protection ▪ Metering ▪ Alphanumeric LCD display ▪ Keypad programming ▪ Modbus RTU communications 13 Power Bus All power bus is isolated behind grounded steel barriers. Automatic shutters are provided to cover the line-side bus stabs whenever a starter door is opened. Horizontal bus ratings range from 600 through 3000 amperes and are further detailed in Table 18. Vertical tap buses in each section are rated 360, 540, or 720 amperes, depending on the application. Insulated bus with boots are available as options. Drawout The Siemens Series 81000 Drawout Medium Voltage Motor Controller is a modular design consisting of up to three vacuum contactors per vertical section each with three current limiting fuses, all housed in a free-standing sheet steel enclosure. The completely drawout contactor carriage (360A) includes all major power components (vacuum contactor, power fuses, CPT, CPT fuses) on a wheeled, drawout carriage. The drawout contactor carriage includes a quick disconnect plug for secondary connections. Drawout fuse carriages are used when loads require 720A vacuum contactors. Contactors are available in up to three high mounting for 5kV and 360A. The drawout controllers are available in a wide range of starter types, including Solid State Reduced Voltage. Solid State Reduced Voltage Controller (SSRVC) Medium Voltage Equipment MV Controllers (MVC) up to 7.2 kV General Fuse Application Table 19 Type FM Fuse Data Maximum Designed Voltage Current Designation 2R (1 barrel) 3R 4R 6R 9R 12R 18R (2 barrel) 24R 38R 57X (3 barrel) 2R (1 barrel) 3R 4R 6R 9R 12R 18R (2 barrel) 24R SWITCHGEAR 13 5080 7200 Continuous Current at 40°C 70 100 130 170 200 230 390 450 600 900 70 100 130 170 200 230 390 450 Minimum Interrupting Capability 190 225 330 500 740 955 1440 1910 3000 4500 190 225 330 500 740 955 1440 1910 Interrupting Rating 50/60 Hz Single Phase 80kA RMS Asymmetrical (210MVA at 2.4kV) (415MVA at 4.8kV) Single Phase 80kA RMS Asymmetrical (620MVA at 7.2kV) Type FM Fuses Installed on 97H3 Contactor For Non-Motor Loads The principal application for ANSI “E” rated fuses in Series 81000 controllers is for non-rotating loads, such as transformer feeders. The following tabulation may be used for estimating which “E” rated fuse is appropriate for a particular 3-phase transformer application. Table 20 Typical Fuse Sizes for Transformer Protection Transformer kVA 45 75 112.5 150 225 300 500 750 1000 1500 2000 2500 3000 Fuse Size at: 2.4kV 25E 30E 40E 50E 80E 100E 200E 250E 400E 450E — — — 4.16kV 10E 15E 20E 30E 40E 65E 100E 150E 200E 300E 400E 450E — 4.8kV 10E 15E 20E 25E 40E 50E 80E 125E 200E 250E 350E 400E 450E 6.9kV — 10E 15E 20E 25E 40E 65E 100E 125E 200E — — — table is accurate for most typical transformer feeder applications. The “E” rated fuses have the same interrupting current ratings as the type FM or A720R “R” rated fuses. Both are rated at 50kA symmetrical and 80kA asymmetrical interrupting. All medium voltage controllers employ current limiting fuses for short circuit protection. The term “current limiting” derives from the operating characteristics of the fuse. Figure 6 shows graphically how, for maximum fault levels, the fuse operates within the first 1/4 cycle of short circuit current. This limits the energy “letthru” well below peak values, thus providing “current limitation.” Note: Fuse sizes are based on 133% overload capacity, except 1500kVA at 2.4kV. 2500kVA at 4.16kV. and 3000kVA at 4.8kV. Figure 6 Current Limiting Effect Fuse ratings higher or lower than those listed in Table 20 may be necessary if the transformer has unusual magnetizing (inrush) current characteristics, or for proper coordination with the secondary protective device (secondary fuse, low voltage circuit breaker trip device, overcurrent relay, etc.). Transformer overload capability may also have a bearing on fuse selection. However, this A mechanical indicator “pops-out” of the end of the fuse if the fuse has operated. This provides a visual means for checking the condition of the fuse, and also acts to engage the optional blown fuse trip bar on the 97H3 contactor. Current designations 2R through 24R (38R and 57X (“X” rated) for fuses on 720A) are used to distinguish one fuse size from another within the same voltage rating. Ampere ratings are not 13-20 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog used to identify medium voltage fuses, since fuse selection involves many different variables. Among these are motor locked rotor and running current, acceleration time, and the time current characteristics of the overload relay used. The fuses are installed on the top of the 97H3 vacuum contactor or on the drawout fuse carriage used with the 96H6 contactor. No fuse pullers or special tools are required to install or replace the fuses. Medium Voltage Equipment MV Controllers (MVC) up to 7.2 kV Dimensions/Specification Table 21 MV Controllers Dimensions and Specification Sheet Enclosure Dimensions in Inches NEMA 1, 1A or 12 Type Drawout or Rating Stationary 42 1 75/90 24 36 42 42 2 90 60/72 96/108 72/96 36 78 114 78/114 78 120 120 2 75/90 60 36 78 78 3 90 60/72 96/108 72/96 36 78 114 78/114 78 120 120 3 75/90 60 78 78 – 90 90 72 36 78 78 – 5kV / 7kV – 90 18 24 36 36 42 42 Drawout Synchronous Full Voltage Non-Reversing (FVNRS) Drawout Synchronous Reduced Voltage-Autotransformer Non-Reversing (RVATS) Drawout Induction Full Voltage 2-Speed 2-Winding (2S2W) Drawout Induction Full Voltage 2-Speed 1-Winding (2S1W) Drawout Latched Contactor Drawout Solid State Reduced Voltage Non-Reversing (SSRV) Drawout Consult Also available in 45" construction for 2-high arrangement, requires top mounted bus. 3 90 1 90 3 90 2 90 3 90 36 72 36 60/72 72/84 72/84 84/108 132/144 132 36 72 72 36 36 36 36 36 36 72 1 30 90 90 2 90 42 78 42 78 78/114 78/114 114 150 150 42 78 78 42 42 78 42 78 78/120 78/120 120 156 156 42 78 78 42 78 78 36 36 42 42 36 36 36 48 36 42 78 78 – 42 42 78 78 – 42 factory. Typical Floor Plan Details for Class E2 Medium Voltage Controllers Detail B — Floor Plan View — Conduit Entry Top Detail A — Floor Plan View — Bottom Conduit Entry Table 22 A 90.00 (2286) K 10.06 (256) MVC Floor Plan Dimensions in Inches (mm) B 36.00 (914) L 6.06 (154) C 32.75 (832) M 4.42 (112) D 31.00 (787) F 1.12 (28) E 21.88 (556) N 3.50 (89) O 2.87 (73) G 4.68 (119) P 29.50 (749) H 2.13 (54) Q 68.50 (1740) J 34.94 (887) R 32.50 (826) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-21 SWITCHGEAR 42 13 36 – Stationary Induction Full Voltage Reversing (FVR) 36 5kV Drawout Incoming Line Main Lugs Only 1 – Stationary LBS Unfused 600A or 1200A LBS 600A Fused or 1200A/900E Fused Depth – Drawout Reduced VoltageAutotransformer Non-Reversing (RVAT) Width 30 90 90 36 72 72 126 36 Stationary Reduced Voltage Primary Reactor Non-Reversing (RVPR) N3RNWI 103" Width 5kV 360A 5kV 720A 7kV 360A 5kV 360A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 5kV 360A 5kV 720A 7kV 360A 15kV 300A 5kV / 7kV Drawout Induction Full Voltage Non-Reversing (FVNR) Height N3R-WI 107" Width Number of Contactors Medium Voltage Equipment SWITCHGEAR 13 MV Controllers (MVC) up to 7.2 kV Motor Protection Options Drive motors often play a decisive role in the functioning of a production process. Motor damage and breakdowns not infrequently lead also to consequential damage and production shutdowns, the cost of which significantly exceeds the cost of repairing the motor. Optimum design of the motor protection ensures that damage following thermal overload is prevented, meaning that there is no reduction to the normal service life. Secondary faults are minimized in the event of short circuits, ground faults and Protective Relaying winding faults. The spectrum extends from small low-voltage motors with an output of a few kW to high voltage motors with outputs measured in MW. Protection system design must be based on the rating of the motor, the importance of the drive for the technological process, the operating conditions and the requirements of the motor manufacturer. Common motor protection functions and SIPROTEC motor protective relay selection tables are provided below. Protection functions for various types of motor faults Fault Protection ANSI Number Stator thermal overload Stator thermal overload protection 49 Rotor thermal overload during start too long or blocked too frequent 2 Protection principles for the rotor overload protection Motor starting time supervision Restart inhibit 48 66, 49R Ground-fault Ground-fault protection (I0>;U0>;<(U0,I0)) 50G, 64G, 67G Short-Circuit Overcurrent time protection Current differential protection 50, 51 87 Loss of phase Negative sequence protection (I2/IN) 46 Bearing overload Temperature sensors (RTD’s) 38 Overheating of plant on unloaded drives (pumps, compressors) Undercurrent protection, Active power protection (P<) 37 32U Undervoltage (starting torque not reached M ~ U2 or start too long Undervoltage protection 27 Asynchronous operation (of a synchronous motor) Underexcitation protection 40 Motor Protection Selection Table Asynchronous Motor 100 kW – 500 kW 7SJ60 Basic device 7SJ61 + more I/O’s + control functions + flexible serial interfaces + better local HMI (4 line display; digital keyboard 500 kW – 2 MW 7SJ62 Basic device + control functions 7UM61 + more I/O’s (7UM612) + control functions + high accuracy + high sensitivity + operating range in a wide frequency band (11Hz - 68Hz) or with control functions via bay mimic diagram in graphic display 7SJ63 7SJ64 Basic device + Synchro check function + high sensitivity + extensive control function + 1 serial interface more > 2 MW Synchronous Motor < 2 MW 7UM61 (Option: Generator Basic) < 10 MW 7UM62 (Option: Generator Basic) > 10 MW 7UM62 + differential protection + control functions + high accuracy + high sensitivity + operating range in a wide frequency band (11Hz - 68Hz) 7UM61 + (Option: Generator Basic) 7UM62 (Option: Generator Basic) or with control functions via bay mimic diagram in graphic display 7SJ64 + (Option: Generator Basic) For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-22 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Medium Voltage Equipment Arc Flash Solutions General boundary, they are still at considerable risk due to intense heat, concussion forces and airborne debris should a fault explosion occur. Now, by allowing operators to remotely perform racking procedures from a distance of up to 40 feet, SARRACS safety breaker system from Siemens provides increased protection for your most important investments: your personnel and your equipment. Protection for your most important investments: your personnel and your equipment! Incidents of serious and sometimes fatal injury have become an all too common occurrence when faults occur while circuit breakers are being racked in or out on a live bus. NFPA 70E-2004 (referenced in OSHA 29CFR-1910-S Appendix “A”) requires that personnel wear full-body flash suits during racking procedures on an energized system. However, as operators must stand within the flash Operator Safety ▪ Remote operation – Personnel safely operate breaker racking system from a distance of up to 40 feet ▪ Eliminates need for special personal protective equipment (PPE) during racking – Since operator is outside the flash boundary, a full-body flash suit is not required ▪ Completely portable – Ball bearing wheels, casters, and transport handle for easy maneuvering Medium Voltage Equipment Arc Flash Solutions Remote Circuit Breaker Controller System Alternate to Arc-Resistant switchgear Siemens can offer a cost effective solution that satisfies the NFPA 70E requirements which provides improved personnel safety when coupled with conventional switchgear. With the Siemens CB Controller (C7) there is no longer a need to stand in front of the circuit breaker cell to view circuit breaker status, operate the circuit breaker or view metering information. All of this can be done from a safe distance from the switchgear. This places the operator or maintenance personnel at a safe distance while they perform these necessary functions. Each lineup would be supplied with its own controller as follows. The system consists of two hardware levels. They are the Siemens SIPROTEC protective relays installed for each circuit breaker in the switchgear and the touch screen CB Controller C7 mounted remote. The two levels are connected via a General Profibus communication link. All necessary security measures are available to prevent unauthorized usage. Siemens will configure the system completely and test all communication functionality and relay data. The above solution in conjunction with remote circuit breaker racking (see SARRACS above) allows for circuit breaker operation and racking without being in front of any circuit breaker during the trip/close function or the racking in/out procedure. When operated correctly, a circuit breaker can be tripped and racked out without being in the flash hazard zone. Typical scheme Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-23 SWITCHGEAR SARRACS™ Remote Breaker Racking 13 SARRACS (with Custom Torque) provides the following: Breaker Safety ® ▪ Utilizes state-of-the-art SIMATIC S7200 PLC from Siemens – Digital position control for consistent and accurate breaker engagement – Customized position-torque control provides protection to minimize equipment damage – Auto reverse (optional) – Speed control – Ramp up/ramp down – Interface options Flexibility ▪ Programmable to allow for varying torque profiles and mechanical requirements of individual circuit breakers in a lineup ▪ Mechanically adjustable to allow for different circuit breakers in the same lineup ▪ Portable and self-contained – Easy to store and transport – Strong but light (approx. 200 lb.) ▪ Designs available for most circuit breakers Siemens Industrial Services can provide training and on-site modificaions if required. Power Switching Centers SWITCHGEAR 13 SIMOSEC Narrow Profile Gas Insulated SIMOSEC Medium voltage metal-enclosed load interrupter indoor switchgear up to 27.6kV. ▪ Extremely compact footprint ▪ Meets ANSI / IEEE C37.20.3 ▪ UL or C-uL listing available ▪ Seismic up to Zone 4 (optional) ▪ High switching capacity – 100 operations @ 600A ▪ Gas insulated three-position switchdisconnector, hermetically sealed for life inside the stainless steel vessel ▪ Switch-disconnector combines the function of a load interrupter switch (with CLOSED-OPEN indication) and a grounding switch (with OPEN-GROUND indication) ▪ HV HRC fuses and cable terminations accessible only if the feeder grounding 13-24 switch is in the grounded position ▪ Fuses and outgoing cables front accessible ▪ Standard viewing window for visible verification of isolating distance ▪ Standard capacitive voltage presence indicator ▪ Integrated mechanical interlocking ▪ Animated mimic diagram ▪ Main bus at top or bottom to suit application ▪ Configurations: individual feeder switches, transformer primary switches & switch lineups ▪ Ideal for utility, construction & industrial applications ▪ Over 20 years experience and more than 350,000 switch-disconnector units installed Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog General SIMOSEC Information on page 13-17 Protective Relays & SCADA Systems SCADA Substation Automation ▪ Completely enclosed packaging; RS-485 switches mounted on outside of chassis ▪ StationManager II is completely software compatible with StationManager I SICAM Remote Terminal Unit OPC DNP HMI Client SICAM Station Mngr. Station Bus IEC 61850 (Ethernet) Modbus, DNP, Profibus DP Protection, Control, Metering Siemens PLC’s Protection, Control, Metering Peer to Peer or Goose Capable DNP Protection, Control, Metering Siemens Siprotec Relay (see Siprotec specific info on page 13-26) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-25 SWITCHGEAR ICCP Protocol Communications ▪ Unexpected events occur in the real world. ICCP runs in “real world” conditions ▪ Secure communications are required to support confidentiality, integrity and availability. ICCP/NT supports secure communication using the ICCP PKI security standard ▪ With critical communications, reliable products are of utmost importance SIPROTEC with IEC 61850 – for more efficient power automation SIPROTEC – the standard for numerical protective relaying – has established itself right across the market. Besides the common system platform and the unique DIGSI 4 service software that may be used for all protective devices, it also supports the new IEC 61850 communication standard. A potential that offers even more efficiency easily and conveniently. IEC 61850 – what it is and what it can achieve Users and manufacturers jointly developed the new international standard IEC 61850. It was approved in early 2004. The agreed aim of this standard is to arrive at a complete communication solution for substations, thus providing users with interoperability among different makes on the basis of Ethernet technology. This opens up a whole new dimension in efficient substation management. Not only short-term savings in operation and maintenance, but also simplified engineering, less complexity, and longterm expandability can make you one of the winners in tomorrow’s power market. Progress. It’s that simple. HMI Client Using a local or web-based HMI from the SICAM PAS you can monitor and control all parts of a system from a central point. The clear display of the operating situation allows you to react fast; you consequently reduce your operating costs and can quickly restore power in the event of malfunctions. As an integrated overall system, SICAM PAS supports you all the way from the bay level to the control center interface with fast data handling, with the flexibility of a programmable-logic controller and with the reliability philosophy of a classic telecontrol unit. Availability and flexibility will help you create state-of-theart, monitoring, control and protection concepts in power automation. 13 SICAM PAS & SICAM StationManager II SICAM PAS (Power Automation System) can meet all the demands made of a distributed substation control system – both now and in the future, too. SICAM PAS was conceived as an open system, i.e., besides providing standardized data transfer processes, it features user interfaces for the integration of systemspecific tasks. SICAM PAS can thus be integrated with ease in existing systems and can be used for system integration. With modern diagnostics, it optimally supports commissioning and maintenance. SICAM PAS is clearly structured and reliable, thanks to its open, fully documented and tested system. SICAM StationManager II combines extensive IED integration capabilities, an IEC 1131 compliant programming interface, some of the best configuration and diagnostic tools in the industry, and various advanced features like WAN support, data encryption and HTML server capabilities, to make it a perfect Substation Data Concentrator. Major Features and Benefits: ▪ Built-in power supply supporting 48 VDC, 125 VDC, and 115 VAC power inputs ▪ Three PC-104 card slots (instead of two); Support for new EPIC processor ▪ Supports two Ethernet fiber converters; Demodulated IRIG-B input General Protective Relays & SCADA Systems SWITCHGEAR 13 SIPROTEC Protective Relays Overview High-performance protective relaying comes into its own when it’s a question of minimizing power system operationg costs. Uncomplicated operation, convenient commissioning tools and flexible communication are all important elements when service and maintenance costs have to be reduced. The Siemens SIPROTEC family with its protection relays and bay control units is an integrated system for medium-voltage to extra-high-voltage applications. Numerical protection systems are nothing new; after all, Siemens has more than 25 years experience in this field. Although system hardware is still often referred to as protection equipment or units – as was once the case with analog technology – it can now do so much more. These relays not only handle fault detection and location tasks but also control, metering and monitoring functions. And it is these additional functions – impossible before the advent of numerical technology – which offer major cost-cutting potential. General IEC 61850 SIPROTEC — the standard for numerical protective relaying — has established itself right across the market. Besides the common system platform and the unique DIGSI 4 service interface that may be used for all protective devices, it also supports the new IEC 61850 communication standard. A potential that offers more efficiency, easily and conveniently. With SIPROTEC relays and bay control units from Siemens we offer all the advantages of an expert and innovative partner in the field of protective relaying and substation automation. We bring you attractively priced intelligent solutions by paying particular attention to lowering your life cycle and system management costs. These solutions are the first ones available on the market with the international IEC 61850 standard. To enable you to profit from these advantages as quickly as possible, Siemens collaborated in the preparation of this international standard and made every effort to ensure no time was lost in bringing it out. The result is certainly worth a look, because SIPROTEC and other Power Automation products and Siemens systems are available on the basis of the IEC 61850 standard and can even be retrofitted in systems supplied since 1998. System advantages ▪ One bay, one unit The SIPROTEC 4 relay family offers fully integrated protection, control, monitoring, and automation functions incorporated in a single device. For many applications, this product contains all the functions you need to meet all your protection and control requirements with just one unit per bay, saving on investment and installation costs and enhancing availability. ▪ DIGSI 4 – one tool for all tasks and products DIGSI 4 is a computer program designed for all SIPROTEC relays. DIGSI 4 offers users a universal tool for all support tasks from setting and commissioning of devices to simple analysis and documentation of system faults. Our powerful analysis tool speeds up troubleshooting and supplies important service information. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-26 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Protective Relays & SCADA Systems SIPROTEC Protective Relays Selection 59 59N 59GN 64 64R ■ ● ✽ ■ ■ ■ — — — — — ■ — — — — — — — — — — — — — — ■ ■ — — — ■ ■ ■ ■ ■ ■ — — — — — — — — — ■ — — — ● — — — — ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — ■ ■ — — ■ ■ ■ ■ ■ ■ ● ● — — ■ ● — — — — — — ■ ■ ■ ■ ■ — — — — — — — ● — — — — — — — ■ ■ — — ■ ■ — — — ● 7SJ62 — — ● ● ● — — — — — — — ● — ● — ● ● ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — — ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ — — — — — — — — — — — — — — — — — ■ — — — — — — — — — — — — ● ● — — — — — — — — — — ● — ● — — — — ● — — ■ ■ — — — — — — ■ ■ ■ ■ ■ ■ ● ● ● — — — ■ ■ ■ ■ ■ ■ — — — ■ ■ — — — — Breaker failure ■ ■ — — — — — — — — — — — — ■ ■ ■ ● ● ■ ■ — ■ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ■ — — — — — — — — — ● ■ ■ ■ — ■ ● ■ ● ● ■ ■ ● ● ■ ■ — ■ ■ ■ ● ■ ■ ■ ● ■ ■ — — ■ — — — ● — ● — — Synchronizing ■ ■ — — — — ■ — ■ — — — — — — — ■ ■ ■ — ■ ■ ■ ■ ■ ■ ■ — — — — ■ ■ ● ■ ■ — ● — — — — ● ● — — — — — — — — — ● ● ■ — — ● ● — — ● ● ■ ■ ■ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ■ ■ — ● — — — — — — — — — — — — — — — — — — — — — — — — — — — ■ ■ — — — — ● ● ■ Breaker management Generator and motor protection ● — — — — — — — — — — — — — — 7RW600 Voltage, frequency ■ ● — — — — — — — ● — — — — — — — — — — — — — — 7SV600 ■ ● ● — — — — 7VE6 ■ ● ● — — — — 7VK61 ■ — — — — ● — — 7UM62 ■ — ■ ● — — — — — — — — — — 7UM61 ■ — ■ ■ — — — — — — — — — — — 7SS52 7UT613 ● — ■ 7SJ63 — — — — — — — — — — — — — 7SJ61 — — — — — — — — — — — — — — ■ 7SJ602 — — — — — — — — — — — — — — 7SA6 — — ● — ● — ● — — — ● — ● — — — — — — — — — — — — — — — ■ 7SS60 7UT612 — — — — — — — — — — — — — — — — — — — — 7UT63 7VH60 Differential 7SJ64 — — — — — — — 7SJ600 — — — — 7SJ46 — — — — — — — — — — — — — 7SJ45 7SD610 Overcurrent Line differential Pilot wire differential Distance 7SA522 — — — — — — — — — — — — — — 7SD5 50BF 51GN 51 51N 51V ● 7SD600 47 48 49 49R 49S 50 50N Protection Function Locked rotor protection Distance protection, phase Distance protection, earth (ground) Fault locator Overfluxing (V/f protection) Synchronizing, synchronism check Undervoltage Stator earth-fault 3rd harmonic Directional power Forward power Reverse power Undercurrent or underpower Loss of field Load unbalance, negative phasesequence overcurrent Phase-sequence voltage Incomplete sequence, locked rotor Thermal overload Rotor thermal protection Stator thermal protection Instantaneous overcurrent Instantaneous earth-fault overcurrent Breaker failure Zero speed and underspeed device Overcurrent-time relay, phase Overcurrent-time relay, earth Overcurrent-time relay, voltage controlled Overvoltage Residual voltage earth-fault protection Stator earth-fault protection 100% Stator earth-fault protection (20 Hz) Rotor earth-fault ■ Standard function Optional ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-27 SWITCHGEAR 14 21 21N 21FL 24 25 27 27/34 32 32F 32R 37 40 46 13 ANSI Number* ANSI Selection List for Protective Relays Protective Relays & SCADA Systems SIPROTEC Protective Relays Selection — — — — — — — — — — — — — — — ● ● ● ● — — — — — — — — — — — — — — — — — — — — ■ ■ ■ ● — — — — — — ● ■ ■ — — — ■ ■ ● ✽ Standard function Optional ANSI/IEEE C37.2: IEEE Standard Electrical Power System Device Function Numbers 1) Only sensitive directional earth-fault overcurrent (67Ns). ■ ■ ■ ■ ■ — — — — — — — — — — — — — — — — — — — — ■ ■ ■ ■ ● — — — — — — — ■ ■ ■ ■ ■ ■ — — — — — — — — ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ● ● ● — — — — — — ■ Breaker management Breaker failure ● — — 7RW600 Voltage, frequency ● ■ 7SV600 — — ● — Synchronizing — ● ■ 7VE6 7UM61 — ● — — — — — — 7VK61 7SS60 — ● ■ Generator and motor protection 7UT63 — — — — — — — 7UM62 7UT613 ■ 7SS52 7UT612 Differential 7SJ63 7VH60 7SJ62 7SJ64 7SJ61 — — ■ 7SA6 7SJ602 ■ 7SJ600 7SD610 Overcurrent Line differential Pilot wire differential Distance 7SA522 ■ ■ — ■ ■ ● ■ — ■ ■ ● ■ — ■ — — — — — — — — — — — — — — — ■ — — — — — — — — — — — — — — — — — — — — ■ ■ ■ — — — — ■ 7SJ46 85 86 87G 87T 87BB 87M 87L 87N — ■ — — — — — ■ — — — ● ● ■ — — — — — — — — — ■ — — — — — — — — — ■ ■ — — — — — — — — — — — — — — — ● — ● — ● — — ● — — — — — — — — ● ■ ● — — — — — — ■ ● ■ — — — — — — — — — — ■ ■ — — — ■ ■ ■ ■ ● ■ — ■1) — ● ■ ■ — ■ — ■ — — — ● ■ — — — — — — — — — — — — — — — — — — — — ● — — — — — — — — — — — — — — ● — — — ● — — — — — — — — — — — ■ ■ 7SJ45 68 74TC 78 79 81 81R Protection Function Directional overcurrent Directional earth-fault overcurrent Stator earth-fault directional overcurrent Power swing detection Trip circuit supervision Out-of-step protection Auto-reclosure Frequency protection Rate-of-frequency-change protection Vector jump supervision Carrier interface/remote trip Lockout function Differential protection generator Differential protection transformer Differential protection busbar Differential protection motor Differential protection line Restricted earth-fault protection 7SD5 67 67N 67G 7SD600 SWITCHGEAR 13 ANSI Number* ANSI Selection List for Protective Relays ● ● — — ● ● ● — ■ ■ ■ ● — — — — — — ■ — — — — — — — — — — — — ■ — ■ — ● — — — — — — — — — — — — — — — For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-28 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ■ ● — — — — — — — — — Protective Relays & SCADA Systems SIPROTEC Protective Relays Selection Siemens Protective Relays - Quick Competitor Comparison by Application Motor Protection Model Siemens Equivalent Typical Catalog Number GE 239 SIMPRO SIMPRO-100-R-N GE 269 SIMPRO SIMPRO-100-R-N GE 269+ SIMPRO SIMPRO-100-R-N GE 369 SIMPRO SIMPRO-100-R-V GE 469 SIMPRO and 7SJ601 SIMPRO-100-R-V/7SJ6015-4EA01-0AA0 Feeder Protection Typical Catalog Number 7SJ45 (1 three phase) 7SJ46 (1 three phase) 7SJ601 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase) 7SJ6015-4EA01-0AA0 (1 three phase) ABB Microshield 7SJ600 7SJ602 7SJ61 7SJ62 7SJ6005-4EA00-0DA1 7SJ6025-4EB00-1FA0 7SJ6115-5EC90-1FA0+L0D 7SJ6215-5EC90-1FE0+L0D ABB DPU-1500 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D ABB DPU-2000R 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D Basler BE3-51 (4 single phase) 7SJ45 (1 three phase) 7SJ46 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase) Basler BE1-51 (4 single phase) 7SJ45 (1 three phase) 7SJ46 (1 three phase) 7SJ601 (1 three phase) 7SJ4505-1EA00-1AA1 (1 three phase) 7SJ4605-1EA00-1AA0 (1 three phase) 7SJ6015-4EA01-0AA0 (1 three phase) Basler BE1-851 7SJ600 7SJ602 7SJ61 7SJ6005-4EA00-0DA1 7SJ6025-4EB00-1FA0 7SJ6115-5EC90-1FA0+L0D Basler BE1-951 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D GE MDP 7SJ45 7SJ46 7SJ601 7SJ4505-1EA00-1AA1 7SJ4605-1EA00-1AA0 7SJ6015-4EA01-0AA0 GE 735 7SJ600 7SJ602 7SJ61 7SJ6005-4EA00-0DA1 7SJ6025-4EB00-1FA0 7SJ6115-5EC90-1FA0+L0D GE 750 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D GE F60 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D SEL 351A 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D SEL 351 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D SEL 351S 7SJ62 7SJ63 7SJ64 7SJ6215-5EC90-1FE0+L0D 7SJ6315-5EC90-1FE0+L0D 7SJ6405-5EC92-1FE4+L0D SEL 501 7SJ600 7SJ602 7SJ61 7SJ6005-4EA00-0DA1 7SJ6025-4EB00-1FA0 7SJ6115-5EC90-1FA0+L0D SEL 551 7SJ600 7SJ602 7SJ61 7SJ6005-4EA00-0DA1 7SJ6025-4EB00-1FA0 7SJ6115-5EC90-1FA0+L0D SWITCHGEAR Siemens Equivalent ABB CO (4 single phase) 13 Model *Siemens catalog numbers in Bold are the preferred equivalent model. Siemens does not accept any liability for the information contained in this document. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-29 Protective Relays & SCADA Systems SIPROTEC Protective Relays Selection SWITCHGEAR 13 General Protection Model Siemens Equivalent Typical Catalog Number ABB GPU2000 7UM62 7UM6215-5EC90-0BA0+L0D Basler BE1- GPS100 7UM61 7UM62 7UM6115-5EC90-0CA0+L0D 7UM6215-5EC90-0BA0+L0D Beckwith M-3420 7UM61 7UM62 7UM6115-5EC90-0CA0+L0D 7UM6215-5EC90-0BA0+L0D Beckwith M-3425 7UM62 7UM6215-5EC90-0CA0+L0D GE 489 7UM61 7UM62 7UM6115-5EC90-0CA0+L0D 7UM6215-5EC90-0BA0+L0D SEL 300G 7UM61 7UM62 7UM6115-5EC90-0CA0+L0D 7UM6215-5EC90-0BA0+L0D Bus Protection Model Siemens Equivalent Typical Catalog Number ABB HU 7VH60 7VH6002-0EA20-0AA0 ABB CA 7VH60 7VH6002-0EA20-0AA0 ABB TPU2000R 7UT513 7UT612 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 Basler BE1-87 7UT513 7UT612 (3) 7VH60 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 7VH6002-0EA20-0AA0 GE PVD 7VH60 7VH6002-0EA20-0AA0 GE B30 7UT513 7UT612 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 SEL 387 7UT513 7UT612 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 Model Siemens Equivalent Typical Catalog Number ABB HU (3) 7UT512 (1) 7UT513 (1) 7UT612 (1) 7UT5125-4GB11-0AA0 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 ABB CA (3) 7UT512 (1) 7UT513 (1) 7UT612 (1) 7UT5125-4GB11-0AA0 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 ABB TPU2000R 7UT512 7UT513 7UT612 7UT5125-4GB11-0AA0 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 Basler BE1-CDS 7UT513 7UT612 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 GE 745 7UT513 7UT612 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 GE T60 7UT513 7UT612 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 SEL 387 7UT513 7UT612 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 SEL 587 7UT512 7UT513 7UT612 7UT5125-4GB11-0AA0 7UT5135-4GB11-1AA0 7UT6125-5EC00-1AA0 Transformer Protection Voltage/Frequency Protection Model Siemens Equivalent Typical Catalog Number Basler BE1-27 7RW600 7RW60000-4EA00-0DA0 Basler BE1-59 7RW600 7RW60000-4EA00-0DA0 Basler BE1-27/59 7RW600 7RW60000-4EA00-0DA0 Basler BE1-81O/U 7RW600 7RW60000-4EA00-0DA0 GE IAV 7RW600 7RW60000-4EA00-0DA0 GE IFV 7RW600 7RW60000-4EA00-0DA0 GE MIV 7RW600 7RW60000-4EA00-0DA0 GE NGV 7RW600 7RW60000-4EA00-0DA0 GE DFF 7RW600 7RW60000-4EA00-0DA0 GE MFF 7RW600 7RW60000-4EA00-0DA0 GE SFF 7RW600 7RW60000-4EA00-0DA0 *Siemens catalog numbers in Bold are the preferred equivalent model. 13-30 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Replacement Breakers & Retrofit Products Medium Voltage Replacement Circuit Breakers Siemens Medium Voltage Replacement Circuit Breakers The following circuit breakers are available as pre-engineered designs. Other manufacturers, models, and ratings can be engineered by Siemens. Transformer Protection Manufacturer Model Allis-Chalmers (All Air-Magnetic) AM 5 MB 7 MC/MCV MA Siemens 3AF (2-High) 15 5 5 7 15 5 7.5 15 GE (All Air-Magnetic) Magneblast (AMH) Magneblast (AM) 4.16 2.4 4.16 7.2 13.8 Westinghouse DH 5 7.5 15 DHP ITE 5 7.5 15 HV 5 HK 7.5 15 Federal Pacific DST2 5 7.5 15 McGraw Edison MOP PSD 27 15 Ratings MVA 150 250 250 500 150 250 500 250 350 350 500 500 750 1000 250 350 500 500 750 1000 250 100 150 100 150 250 350 500 250 500 750 1000 150 250 350 500 500 750 1000 350 500 500 750, 750C 1000 100 150 250 500 500 750 1000 250 500 500 750 1000 501 502 751 AMP 1200, 2000 1200, 2000 1200, 2000 1200, 2000 1200 1200, 2000 1200, 2000 1200, 2000 1200, 2000 3000 1200, 2000, 3000 1200, 2000 1200, 2000 1200, 2000, 3000 1200, 2000 1200, 2000, 3000 1200, 2000, 3000 1200, 2000 1200, 2000 1200, 2000, 3000 600, 1200, 2000 600, 1200, 2000 600, 1200, 2000 600, 1200, 2000 600, 1200, 2000 600, 1200, 2000 1200, 2000, 3000 1200, 2000, 3000 1200, 2000 1200, 2000 1200, 2000 1200, 2000, 3000 1200, 2000 1200, 2000 3000 1200, 2000 1200, 2000 1200, 2000 1200, 2000, 3000 1200, 2000 1200, 2000 1200, 2000 1200, 2000 1200, 2000 600, 1200 600, 1200 600, 1200 1200, 2000 1200, 2000 1200, 2000 1200, 2000 1200, 2000 1200, 2000 1200, 2000 1200, 2000 1200 1200 2000 1200 5-MSV (replacement for Allis-Chalmers MA) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-31 SWITCHGEAR FA FB FC/FCV kV 13 Ratings from 5–38 kV, 250–1500 MVA, 1200-3000 Amperes Replacement circuit breakers provide a cost-effective way to upgrade your system capabilities while saving you from costly maintenance and lost productivity and preserving your investment in existing cubicles and cables. Whether your equipment was originally manufactured by Allis-Chalmers, Westinghouse, GE, Federal Pacific, ITE, or another manufacturer, we will assist you to evaluate the Siemens replacement options which best meet your needs. Why Replacement Breakers? ▪ Increased Reliability and Performance ▪ Reduced Operating and Maintenance Expenditures ▪ Reduced Downtime, Minimal Changeover Time During Upgrade ▪ Preserved Investment in Existing Cubicles ▪ Improved Employee and Environmental Safety Why Siemens? Siemens Offers the Best Vacuum Circuit Breaker in the Industry. ▪ Superior Performance, Longer Service Life – 10,000 full load operation, 10-year maintenance cycle on replacement circuit breakers with 3AH operator ▪ Standard Operator on All Siemens Replacement, Medium Voltage Distribution, and Outdoor Vacuum Circuit Breakers ▪ Extensive Replacement Breaker Experience – 750+ projects since 1983 – Over 400,0000 3AF/H series circuit breakers in service worldwide – Nuclear Class 1E Rated (350+ breakers) ▪ Full Range of Service Capabilities by Skilled Factory-Trained Engineers and Technicians General Replacement Breakers & Retrofit Products SWITCHGEAR 13 Safety Racking Solutions Siemens GM Switchgear Electric Racking Accessory An optional electric racking accessory is available for 5-15kV GM, GM-SG, and 38kV GM38 switchgear. The switchgear requires modifications to the front panel to add mounting adapters for the motor drive mechanism. The accessory consists of a motor drive enclosure which installs on mounting brackets on the switchgear front panel of a circuit breaker compartment. The unit includes a power cord, which can be connected to a convenient power source in the vicinity of the switchgear. Instructions for mounting the racking accessory and for racking of circuit breakers are provided on a label on the racking accessory. Allis-Chalmers D and F Switchgear— Closed Door Racking Modification In order to improve operator safety, Siemens offers a field modification to convert type D and F switchgear to a closed-door, remote rack design. This modification provides a cost effective solution to keep operators clear of the arc flash zone during breaker racking. Allis-Chalmers and later Siemens manufactured type D and F mediumvoltage switchgear from 1958 through the late 1980’s. This gear utilized airmagnetic breakers that were typically manually racked via a lever while the cubicle panel door was open. The field modification consists of a floormounted screw racking device and a breaker-mounted bracket to interface with the floor-mounted screw device. These additions allow end-users to either have closed-door manual racking, or closed-door remote racking. The closed-door remote racking option requires the above mentioned cell and breaker additions, as well as a minor front panel modification to accept a torque-regulated motor. The motor can be moved from one cell position to the next, thus only one motor device is required. General Figure 7 Motor drive mounted on CB cubicle door. Figure 8 Power and Control switch units. Before: Original floor-mounted lever racking, commonly used on type D and F switchgear, required the operator to stand in front of the breaker with the panel door open. After: Following the field modification, the breaker can be racked in and out while the operator stands outside of the arc flash zone. Manuf. Model Allis-Chalmers D Gear MA F Gear kV Ratings MVA AMP 5 250 350 350 500 500 750 1000 1200, 1200, 3000 1200, 1200, 1200, 1200, FA 5 FB 7 FC/FCV 15 2000 2000 2000, 3000 2000 2000 2000, 3000 Easily installed on existing units and can be provided for 5kV, 7.5kV, and 15kV ratings, from 1200A through 3000A. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-32 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Field Services Start-up Commissioning Services Check tightness of connections Lubricate as required Perform a contact resistance test Perform an insulation resistance test at 1000 volts DC from pole-to-pole and from each pole-to-ground with breaker closed and across open contacts of each phase ▪ Perform secondary current injection testing ▪ More ▪ ▪ ▪ ▪ Low Voltage Switchgear Startup Service ▪ Perform mechanical operational test ▪ Check cell fit and element alignment SWITCHGEAR Medium Voltage Switchgear Startup Service ▪ Inspect anchorage, alignment and grounding ▪ Check tightness of bolted bus joints ▪ Measure and record critical distances such as contact gap ▪ Perform mechanical operation tests on the operating mechanism ▪ Perform a contact resistance test on the breaker vacuum contacts ▪ Perform insulation resistance tests ▪ Perform vacuum interrupter integrity (over-potential) tests ▪ Perform insulation resistance test on all control wiring at 1000 volts DC ▪ Verify trip, close, trip-free and antipump functions ▪ More 13 We realize that, even though our Totally Integrated Automation® and Totally Integrated Power® products are designed for quick and easy installation, your schedule may not allow you to allocate the resources and personnel necessary to get this equipment up and running when it is required. In today's business environment, staff members are frequently overloaded, or they may be dedicated to other projects. Now, when you purchase new equipment from Siemens, you can add startup services at special rates. This will give you the additional help required to meet even the most pressing deadlines... at affordable rates. You can be confident that we will arrive at your door with the installation experience necessary to get your new general purpose drives, motor control center or switchgear properly started up and working when you need it. Factory-trained engineers will: ▪ Startup your newly-purchased Siemens equipment ▪ Test for operational functionality ▪ Provide a written report detailing tests and services ▪ Advise your team on upkeep and maintenance. In many cases, you will receive a oneyear parts warranty extension on your new equipment such as: ▪ Motor control centers ▪ General purpose variable speed drives ▪ Low voltage switchgear. Bonus: Receive an additional one-year parts warranty when you purchase Siemens startup services with your new motor control centers, general purpose variable speed drives and/or low voltage switchgear. General Switchboards and Power Switching Centers ▪ Inspect for physical damage and nameplate compliance with single line diagram ▪ Perform mechanical operational test. (circuit breakers, switches, etc.) ▪ Check cell fit and element alignment ▪ Check tightness of connections and lubricate ▪ Perform a contact resistance test on RL/WL/SB breakers and power switches ▪ Perform an insulation resistance test at 1000 volts DC from pole-to-pole and from each pole-to-ground with breaker or switch closed and across open contacts of each phase ▪ Perform Secondary Current Injection Testing (RL/WL/SB breakers) ▪ More For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-33 Field Services Start-up Commissioning Services General ▪ Ensure incoming line power connections comply with UL/NEC requirements where applicable ▪ Ensure that any special motor starting and running applications have been considered when selecting motor starter controls, and that main metering is functioning properly ▪ Perform startup on drives, solid state/ soft-start starters and other equipment ▪ More ▪ ▪ ▪ 13 ▪ SWITCHGEAR ▪ Motor Control Center Startup Service ▪ Ensure that all protective devices have been properly set and locked ▪ Review power fuse selection and installation procedures ▪ Conduct a general physical inspection of MCC power and control connections. Check tightness of connections after installation and wiring (per drawings) Make final adjustments such as speed range, acceleration/deceleration and tuning to motor Check starting, stopping, interlocking and sequencing (per drawings) Check and adjust for purchased options such as bypass, braking, serial communications, encoder interface, and line filters Verify power quality (MM440 units only) More General Purpose Variable Speed Drives Startup Service ▪ Inspect electrical and mechanical parts Engineer-by-the-Day for new equipment purchases *Minimum purchase required. Extended warranty not vailable with Engineer-by-the-Day service. Now, you can take advantage of the expertise of a Siemens factory-trained engineer to startup your Siemens power distribution and control equipment purchases. Engineer-by-the-Day is available in complete one-day increments for setup of the following products*: ACCESS power monitoring ▪ Busway ▪ 13-34 ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Dry type transformers Insulated case circuit breakers Molded case circuit breakers Panelboards Sensitrip circuit breakers Switchboards Switches More Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Siemens Energy & Automation is committed to ensuring that your equipment is up and running...when you need it. Siemens Industrial Services provides expert factoryauthorized equipment startup at a special rate when you purchase the service before your product is delivered. Get your equipment up and running on time. Contact your local distributor or Siemens Energy & Automation sales office to learn more. Field Services Power System Studies General/Selection power system specialists will study the transient response of rotating equipment following system disturbances, and analyze system behavior in relation to the power company tie. Coordination Study Under fault conditions, systems should isolate the faulted area to minimize disturbance to the remaining system, and simultaneously limit damage to equipment. We will review the characteristics of your protective devices, then provide the settings necessary to ensure that your system functions optimally should a fault occur. Harmonic Analysis As AC drives have become increasingly prevalent in industry, we have seen the introduction of destructive harmonics to many systems. The power quality experts from Siemens will determine the extent and severity of harmonics in your system, then recommend the appropriate means of limiting potential damage. Transient Stability Study This study is particularly valuable for facilities that generate their own power, and those with very large motors. Our Power Quality Assessment With the proliferation of sensitive electronic equipment in recent years, power quality has become a major concern for industry. We perform structured, step-by-step studies with timely diagnosis and expert solutions to the complex challenges of utility and end-user power quality issues. Arc Flash Study NFPA 70E recommends that an Arc Flash Hazard Analysis be performed prior to work on electrical equipment. Siemens will determine the incident energy levels, Arc Flash Boundary (AFB), and required level of Personal Protective Equipment (PPE). Load Flow Study This steady-state analysis of your system’s capability to supply the connected load will produce a listing of real and reactive power flow in each line or branch, and the bus voltages, under both normal and abnormal system conditions. Voltage Unbalance Study Voltage flicker and poor voltage regulation are a common concern on systems with large arc furnaces. The experts from Siemens use this study to develop comprehensive solutions that limit the effects of voltage irregularities and protect sensitive equipment. In addition, the power system specialists from Siemens also provide the following: Power System Studies on “Equipment Release for Manufacture” ▪ To ensure adequate interrupting rating, and to ensure that coordination capabilities are recognized Streamlined Power System Construction Studies (PSCS) ▪ For devices being installed on construction projects For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-35 SWITCHGEAR Short Circuit Study Power system specialists from Siemens will determine the maximum duty that your system’s protective devices, transformers, and interconnections will be subjected to in the event of three phase and/or line-to-ground fault conditions. In addition, we will provide basic information required to establish protective relay settings. With power system expertise and experience that comes from real-world successes, the specialized team of professional engineers and certified technicians from Siemens will help you: ▪ Minimize downtime ▪ Improve the safety of your operations for employees and sub-contractors ▪ Optimize your system’s performance ▪ Extend your equipment’s life cycle ▪ Reallocate your valuable internal maintenance resources to your core business ▪ Maximize the protection of sensitive electronics ▪ Ensure your facility complies with applicable safety regulations 13 Protective Device Evaluation With the objective of achieving optimum protection, we will perform the necessary calculations required to select the interrupting rating of power fuses, circuit breakers, and other protective devices. Grounding Study With the goal of ensuring proper protection and reducing the possibility of excessive transient overvoltages during line-to-ground faults, our engineers will determine and recommend the most appropriate form of system grounding protection (including solidstate, low resistance, and high resistance). Field Services Arc Flash Study General SWITCHGEAR 13 The Siemens solution to minimize risks from arc flash hazards Arc Flash Hazards In the fraction of a second that it takes copper to expand to vapor, an arc flash can generate skin-searing heat — four times hotter than the surface of the sun. Recent revisions to NFPA70E require that an Arc Flash Hazard Analysis be performed prior to working on or near electrical equipment containing exposed energized conductors. The analysis determines the arc flash boundaries (AFB), incident energy levels and the required level of personal protective equipment (PPE). The recommendations in the analysis can be used to determine hazards in your workplace. Implementing the recommendations will help protect your workers and help you satisfy OSHA requirements. Working within NFPA and IEEE guidelines, our experienced power systems engineers will perform systematic and accurate Arc Flash Hazard Studies as follows: 1. Short Circuit Calculations Siemens will either use your data, or make calculations for you, to identify bolted and arcing fault levels at key points in a power distribution system. 2. Protective Device Coordination Using the customer’s electrical systems coordination study, Siemens determines the duration of the arcing faults. 3. Arc Flash Hazard Calculations The incident energy level, the flash hazard boundary, and the PPE required are then calculated for each location. 4. Documentation The information above is compiled for you into a comprehensive report, which contains information necessary to comply with regulatory requirements. 5. Unsafe Work Locations The report will identify work locations having incident energy levels in excess of available PPE ratings. 6. Arc Flash Hazard Mitigation Recommendations will be made to minimize Arc Flash Hazards by changes in system protection or operational procedures. 7. Arc Flash Hazard Labels In addition to the report, our customers will receive a field label containing the flash hazard boundary distance, incident energy level, PPE category and shock hazard for each location. Implementing recommendations from a Siemens Arc Flash Hazard Study can bring you the following benefits: ▪ Improve employee safety ▪ Improve your electrical system ▪ Provide safety information to subcontractors ▪ Assist in compliance with regulations ▪ Provide you with documentation that may bring about reductions in workers compensation and insurance rates Turn to Siemens for Arc Flash Hazard Studies, comprehensive safety training and other related services that will enhance the safety of your personnel and the reliability of your operation. SARRACS — Complete arc flash protection for switchgear racking. After completion of your Arc Flash Hazard Study and Equipment Labeling efforts, why not consider another aspect to your personnel safety initiatives? Why not consider Siemens’ SARRACS remote circuit breaker racking system? Racking medium voltage circuit breakers (>1000V) into and out of a live bus is one instance where the PPE required may not be adequate to protect personnel from arc flash. Siemens SARRACS effectively removes the operator from the arc flash boundary by allowing for remote installation or removal. In addition, SARRACS provides torque monitoring to detect improper breaker connection. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-36 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Secondary Unit Substations Overview General 13 Switchboard with WL Encased Systems Breakers Primary Switch Liquid Filled Transformer Type SB3 Switchboard with Fusible Switches Dry Type Transformer Primary Switch Liquid Filled Transformer Primary Switch Type WL Low Voltage Switchgear For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-37 SWITCHGEAR Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically and electrically connected to and coordinated in design with one or more switchgear or switchboard assemblies. A secondary unit substation is defined as a unit substation whose outgoing section is rated below 1000 volts. A typical secondary unit substation consists of three sections: ▪ Primary: an incoming section that accepts incoming high voltage (2400 to 13,800 volts) line ▪ Transformer: section that transforms incoming voltage down to utilization voltage (600 volts or less) ▪ Secondary: an outgoing section that distributes power to outgoing feeders and provides protection for these feeders (600 volts and less) Standard secondary unit substations consist of: ▪ Medium Voltage Primary ▪ Transformer ▪ Low Voltage Secondary Siemens also offers low voltage unit substations with: ▪ Low Voltage Primary ▪ Transformer ▪ Low Voltage Secondary The primary reason for using a secondary unit substation is to bring power as close as possible to the center of the loads. Another reason is that it provides a system design concept incorporating a wide variety of components that permits tailoring equipment to the needs of the application. A secondary unit substation provides ▪ Reduced power losses ▪ Better voltage regulation ▪ Improved service continuity ▪ Increased functional flexibility ▪ Lower installation cost ▪ Efficient space utilization Every component and assembly of secondary unit substations are designed and engineered as an integral part of a complete system. Secondary Unit Substations Transformers — Dry Type Dimensions 10.5 in. (266.7 mm) DANGER H + 3.25 in. (82.6 mm) 8.0 in. (203.2 mm) FAN CONTROL PANEL FRONT 13 2.75 in. (69.85 mm) GROUND BUS SWITCHGEAR 8.0 in. (203.2 mm) 12.63 in. (320.8 mm) 4.0 in. (101.6 mm) 1.81 in. (45.97 mm) High Voltage Terminal Table 23 5kV and 15kV Ventilated Dry Type Transformers 115˚C or 150˚C Temp Rise 5 kV = 30 kV BIL, 15 kV = 60 kV BIL 80˚C Temp Rise 5 kV = 30 kV BIL, 15 kV = 60 kV BIL Approx. Dim. in Inches (mm) weight— W D Lbs. (kg) H 90 48 48 2,200 (2286) (1219) (1219) (998) Dim. in Inches (mm) kVA W D Rating H 48 48 90 225 (1219) (1219) (2286) Approx. weight— Lbs. (kg) 2,500 (1134) 115˚C or 150˚C Temp Rise 5 kV = 60 kV BIL, 15 kV = 95 kV BIL Approx. Dim. in Inches (mm) weight— H W D Lbs. (kg) 80˚C Temp Rise 5 kV = 60 kV BIL, 15 kV = 95 kV BIL Dim. in Inches (mm) H W D Approx. weight — Lbs. (kg) — — — — — — — — 300 90 (2286) 78 (1981) 48 (1219) 2,500 (1134) 90 (2286) 78 (1981) 48 (1219) 3,150 (1429) 90 (2286) 78 (1981) 48 (1219) 3,150 (1429) 90 (2286) 78 (1981) 48 (1219) 3,300 (1499) 500 90 (2286) 78 (1981) 48 햲 (1219) 3,150 (1429) 90 (2286) 78 (1981) 48 햲 (1219) 4,150 (1882) 90 (2286) 78 (1981) 48 (1219) 4,150 (1882) 90 (2286) 78 (1981) 48 햲 (1219) 4,400 (1996) 750 90 (2286) 78 (1981) 48 햲 (1219) 4,150 (1882) 90 (2286) 78 (1981) 48 햲 (1219) 5,050 (2291) 90 (2286) 90 (2286) 58 (1473) 5,100 (2313) 90 (2286) 90 (2286) 58 (1473) 5,500 (2495) 1000 90 (2286) 78 (1981) 48 햲 (1219) 5,050 (2291) 90 (2286) 78 (1981) 48 햲 (1219) 6,550 (2971) 90 (2286) 90 (2286) 58 (1473) 6,600 (2994) 90 (2286) 102 (2591) 58 (1473) 7,400 (3357) 1500 90 (2286) 90 (2286) 48 햲 (1219) 6,700 (3039) 90 (2286) 90 (2286) 48 햲 (1219) 8,050 (3652) 90 (2286) 102 (2591) 58 (1473) 8,050 (3652) 90 (2286) 112 (2845) 58 (1473) 14,000 (6350) 2000 90 (2286) 90 (2286) 58 (1473) 8,050 (3652) 90 (2286) 102 (2591) 58 (1473) 13,000 (5897) 90 (2286) 112 (2845) 58 (1473) 13,000 (5897) 102 (2591) 112 (2845) 58 (1473) 14,000 (6350) 2500 102 (2591) 112 (2845) 58 (1473) 13,000 (5897) 102 (2591) 112 (2845) 58 (1473) 16,000 (7258) 102 (2591) 112 (2845) 58 (1473) 16,000 (7258) 110 (2794) 112 (2845) 58 (1473) 16,000 (7258) 3000 110 (2794) 120 (3048) 58 (1473) 14,000 (6350) 110 (2794) 120 (3048) 58 (1473) 18,000 (8165) 110 (2794) 120 (3048) 58 (1473) 18,000 (8165) 110 (2794) 120 (3048) 58 (1473) 18,000 (8165) Table 24 5kV and 15kV Cast Coil Type Transformers 115˚C or 80˚C 5 kV = 75 kV BIL kVA Rating 햲 1.81 in. (45.97 mm) W Front View Outdoor 115˚C or 80˚C Rise 15 kV = 95 kV BIL Dim. in Inches (mm) H W Weight in Lbs. (kg) D Approx. Weight in Lbs. (kg) Dim. in Inches (mm) H W D 500 90 (2286) 90 (2286) 58 (1473) 5,200 (2359) 90 (2286) 90 (2286) 58 (1473) 5,400 (2449) 750 90 (2286) 96 (2438) 58 (1473) 6,900 (3130) 90 (2286) 96 (2438) 58 (1473) 7,200 (3266) 1000 90 (2286) 102 (2591) 58 (1473) 8,400 (3810) 90 (2286) 96 (2438) 58 (1473) 8,500 (3856) 1500 90 (2286) 108 (2743) 58 (1473) 11,200 (5080) 96 (2438) 102 (2591) 58 (1473) 12,900 (5851) 2000 102 (2591) 114 (2896) 58 (1473) 13,200 (5988) 102 (2591) 114 (2896) 58 (1473) 13,900 (6305) 2500 108 (2743) 120 (3048) 58 (1473) 15,300 (6940) 108 (2743) 120 (3048) 58 (1473) 15,900 (7212) 3000 114 (2896) 126 (3200) 58 (1473) 18,200 (8256) 114 (2896) 126 (3200) 58 (1473) 18,900 (8573) 208V secondary requires 58 in. (1473 mm) deep enclosure. 13-38 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Secondary Unit Substations Transformers — Liquid Filled Type Dimensions 13 SWITCHGEAR 5kV and 15kV Liquid-Filled Transformer Table 25 kVA Rating 500 750 1000 1500 2000 2500 Table 26 kVA Rating 500 750 1000 1500 2000 2500 3000 3750 햲 Consult 5kV and 15kV Silicone Liquid Transformers 65°C Temp. Rise Dimensions in Inches (mm) A B 70.5 (1791) 59.5 (1511) 72.5 (1842) 81.0 (2057) 74.5 (1892) 75.0 (1905) 79.5 (2019) 81.0 (2057) 79.5 (2019) 102.5 (2604) 79.5 (2019) 110.5 (2807) C 52.00 (1321) 53.00 (1346) 56.00 (1422) 59.00 (1499) 59.00 (1499) 59.00 (1499) D 21.50 (546) 40.50 (1029) 40.50 (1029) 40.50 (1029) 53.25 (1353) 57.25 (1454) Weight Lb. (kg) 4190 (1901) 6450 (2926) 7630 (3461) 9500 (4309) 12070 (5475) 14190 (6437) 55°C/65°C Temp. Rise Dimensions in Inches (mm) A B 70.5 (1791) 76.0 (1930) 72.5 (1842) 81.0 (2057) 80.5 (2045) 81.0 (2057) 80.5 (2045) 103.5 (2629) 89.5 (2273) 122.5 (3112) 89.5 (2273) 130.5 (3315) C 52.00 (1321) 53.00 (1346) 56.00 (1422) 59.00 (1499) 59.00 (1499) 59.00 (1499) D 38.00 (965) 40.50 (1029) 40.50 (1029) 51.75 (1314) 61.25 (1556) 65.25 (1657) 55°C/65°C Temp. Rise Dimensions in Inches (mm) A B 70.5 (1791) 53.5 (1359) 70.5 (1791) 75.0 (1905) 70.5 (1791) 81.0 (2057) 72.5 (1842) 81.0 (2057) 76.5 (1943) 98.5 (2502) 76.5 (1943) 106.5 (2705) 76.5 (1943) 106.5 (2705) 77.5 (1969) 124.5 (3162) C 52.00 (1321) 53.00 (1346) 56.00 (1422) 59.00 (1499) 59.00 (1499) 59.00 (1499) 70.00 (1778) 72.00 (1829) D 21.50 (546) 40.50 (1029) 40.50 (1029) 40.50 (1029) 49.25 (1251) 53.25 (1353) 53.25 (1353) 62.25 (1581) Weight Lb. (kg) 4390 (1991) 6890 (3125) 8350 (3788) 11300 (5126) 13920 (6314) 15230 (6908) 5kV and 15kV Mineral Oil Filled Transformers 65°C Temp. Rise Dimensions in Inches (mm) A B 70.5 (1791) 53.5 (1359) 70.5 (1791) 58.5 (1486) 70.5 (1791) 64.5 (1638) 72.5 (1842) 64.5 (1638) 76.5 (1943) 78.0 (1981) 76.5 (1943) 84.0 (2134) 76.5 (1943) 98.5 (2502) 77.5 (1969) 108.5 (2756) C 52.00 (1321) 53.00 (1346) 56.00 (1422) 59.00 (1499) 59.00 (1499) 59.00 (1499) 70.00 (1778) 72.00 (1829) D 21.5 (546) 24.0 (610) 24.0 (610) 24.0 (610) 36.0 (914) 42.0 (1067) 49.25 (1251) 54.25 (1378) Weight Lb. (kg) 4100 (1860) 6200 (2812) 7140 (3239) 8800 (3992) 10250 (4649) 13730 (6228) 햲 햲 Weight Lb. (kg) 4270 (1937) 6420 (2912) 7720 (3502) 9550 (4332) 10650 (4831) 14250 (6464) 햲 햲 Siemens for weight. Note: Dimensions and weights on this page are for estimating purposes only, not for construction. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-39 Secondary Unit Substations Transition Sections General SWITCHGEAR 13 A transition section is required between the transformer and the primary section, and between the main device section of the switchboard for a liquid filled transformer. Connection between the transformer secondary and the main bus of the switchboard is made with flexible connectors. Transition Section Flexible Connectors Between Transformer Secondary and Main Bus of Switchboard High Voltage Transition Section Between Primary Switch and Transformer Table 27 Transformer Oil, RTEmp, Silicone Width in Inches (mm) Depth 햲 20 (508) Ventilated Dry Type 햳 20 (508) 햲 Outdoor Cast-Coil 햳 20 (508) 햲 햲 Same depth as primary switch section. 햳 Transition section is not required (optional). Low Voltage Transition Section Between Transformer and Low Voltage Switchboard Table 28 Dimensions in Inches (mm) Ventilated Dry Type and Liquid Filled Cast Coil Transformer Transformer 햳 Amp Rating W D W D 600 20 20 햲 햲 800 (508) (508) 10000 1200 20 20 햲 햲 1600 (508) (508) 2000 2500 20 20 햲 햲 3000 (508) (508) 4000 햲 Same depth as primary switch section. 햳 Transition section is not required (optional). Switchboard secondary defines requirements. Consult Siemens for specific requirements. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-40 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Secondary Unit Substations ▪ Switchboard Secondary Note: See Section 12 for Switchboard Secondaries 13 SWITCHGEAR ▪ Switchgear Secondary Note: See Pages 42-51 for WL Switchgear Secondary For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-41 Low Voltage Switchgear SWITCHGEAR 13 Type WL Low Voltage Metal-Enclosed Switchgear General Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of the Type WL low voltage switchgear is the World Class Siemens WL breaker. Siemens Type WL low voltage switchgear can be utilized in the following applications: ▪ Industrial ▪ Institutional ▪ Critical Power ▪ Utility and co-generation ▪ Commercial Product Scope ▪ Equipment ratings 635VAC Maximum 3-Phase 3-Wire, 3-Phase 4-Wire 50/60 Hz 6000 amp maximum horizontal bus 5000 amp maximum vertical bus ▪ Enclosure options NEMA 1 Indoor NEMA 3R Outdoor Walk-in NEMA 3R Outdoor Non Walk-in Type WL Low Voltage Metal-Enclosed Switchgear Exclusive Features Generator/Utility Protection Sets 24/7/365 power availability is critical for some systems. On-site generation capability is growing more and more common in many systems. All of the WL digital electronic trip units allow the system designer to precisely tailor trip settings for the most demanding requirements. However, the 755 and 776 trip units allow one set of trip settings for a fully loaded utility feed and with a simple contact closure, the trip unit toggles to a second trip set tailored to provide optimal generator protection. The wide range of settings allows the WL to provide protection for a minimal generator capacity for only essential loads, through full backup for an entire facility. This dual utility/generator protection capability in a single circuit breaker allows the system designer unparalleled, costeffective flexibility. Extended Instantaneous Protection (EIP – Patent Pending Feature) Another unique feature of the WL Trip Unit, allows the system designer to achieve full selective trip coordination up to the short-time rating of the frame, while also allowing application of the breaker up to the interrupting rating of the frame. EIP allows the WL breaker to be applied up to the full withstand rating of the breaker, for complete coordination, with a minus 0% short- time band tolerance up to 85kA on Frame Size II and 100kA on Frame Size III. Above fault currents of 20% higher than the full short-time rating, the WL breaker is self protecting, and the EIP function will trip the breaker instantly to protect the frame and the system from these extremely high currents, as high as 150 kA on Frame Size III. One added benefit is that arc flash energy is greatly reduced in this high current region due to the instantaneous trip response that EIP provides. Industry Standards Type WL switchgear with power circuit breakers are designed, tested and constructed in accordance with: ▪ UL 1558—Metal-Enclosed Low Voltage Power Circuit Breaker Switchgear ▪ ANSI C37.20.1—Metal-Enclosed Low Voltage Power Circuit Breaker Switchgear WL drawout circuit breakers are designed for continuous operation at 100% of their current rating without the need for external heat sinks, and are in accordance with: ▪ UL 1066—Low Voltage AC and DC Power Circuit Breakers Used in Enclosures ▪ ANSI C37.13—Low Voltage AC Power Circuit Breakers Used in Enclosures For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-42 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear Specifications WL Low Voltage Metal-Enclosed Switchgear Features & Benefits Frame Rating Rating Designation Interrupting Current Ics (kAIR RMS) 50/60 Hz Frame Size II 1600 800 254VAC 2000 3200 N S H L F N S H L F S H L F S H L 50 65 85 100 200 50 65 85 100 200 65 85 100 200 65 85 100 508VAC 50 65 85 100 200 50 65 85 100 200 65 85 100 200 65 85 100 635VAC 50 65 65 85 200 50 65 65 85 200 65 65 85 200 65 65 85 (kA RMS) 50/60 Hz 0.5s 50 65 65 85 20 50 65 65 85 20 65 65 85 20 65 65 85 Extended Instantaneous 285- Short-time Withstand Current lcw Protection 508VAC 50 65 85 100 200 50 65 85 100 200 65 85 100 200 65 85 100 (kA RMS - 0% to 20+%) 635VAC 50 65 65 85 200 50 65 65 85 200 65 65 85 200 65 65 85 50 65 65 85 75 50 65 65 85 75 65 65 85 75 65 65 85 Close & Latch Ratings (kA RMS) 50/60 Hz Rating Plug Range 200A to 800A 200A to 1600A 200A to 2000A 200A to 3200A Endurance Rating (switching operations with maintenance) 햲 Mech. 15,000 15,000 15,000 15,000 Elec. 15,000 15,000 15,000 15,000 Frame Size III Frame Rating Rating Designation Interrupting Current Ics (kAIR RMS) 50/60 Hz 3200 4000 5000 M F H L M F H L M F 254VAC 150 200 85 100 150 200 85 100 150 200 508VAC 150 200 85 100 150 200 85 100 150 200 635VAC 85 200 85 85 85 200 85 85 85 200 0.5s 100 40 85 100 40 85 100 Short-time Withstand Current lcw (kA RMS) 50/60 Hz 햳 햳 햳 100 햳 햳 100 40 Extended Instantaneous 254VAC Protection 508VAC 150 200 85 100 150 200 85 100 150 200 (kA RMS - 0% to 20+%) 635VAC 85 200 85 85 85 200 85 85 85 200 40 85 100 40 85 100 Close & Latch Ratings 햳 (kA RMS) 50/60 Hz 100 Rating Plug Range 800A to 3200A 햳 햳 100 800A to 4000A 햳 햳 100 40 800A to 5000A Endurance Rating (switching operations with maintenance) 햲 Maintenance 햲 Mech. 10,000 10,000 10,000 Elec. 10,000 10,000 10,000 means: Replacing main contacts and arc chutes (see operating instructions). Main contacts in breakers with Rating Designation M can only be replaced by Siemens personnel. 햳 Do not apply breaker at 635V AC on a system with available fault current > 85kA RMS. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-43 SWITCHGEAR Breaker Ratings 13 ▪ Breaker racking handle integral to the breaker ▪ All breaker settings and displays clearly visible with breaker door closed ▪ Field installable “drop in place” accessories and trip units ▪ Same accessories work for entire breaker line ▪ ModBus, ProfiBus and Ethernet communication ▪ Field installable ground fault protection and zone selective interlock ▪ Rogowski coil current sensors provide high metering accuracy and prevent saturation at high current levels ▪ Dynamic Arc Flash Sentry (DAS) and EIP (Extended Instantaneous Protection) are patent pending features from Siemens that greatly reduce Arc Flash Energy ▪ Control and communication termination area located in front of equipment and segregated from power cable termination area that is located in rear of equipment ▪ Front accessible vertical and horizontal wiring channels ▪ Easy access to control and communication connections through separate front door ▪ No heat sinks on breaker or bus ▪ No front-breaker door ventilation ▪ 100kA bus bracing standard - 150kA and 200kA optional ▪ Insulated/isolated bus through 6000 amps ▪ Three levels of horizontal bus through 5000 amps ▪ Modular design for maximum configuration flexibility Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear SWITCHGEAR 13 Main and Ground Bus The standard main bus is silver-plated copper. Tin-plated copper bus is optionally available. Vertical and horizontal bus bar utilize a channel shape design to maximize short circuit withstand capability and minimize heat rise. All bus joints include Grade 5 bolts and conical spring washers. Provisions for future extension of the main bus include plated joints and high tensile strength steel hardware. The main three phase horizontal bus is arranged vertically one phase above the other with edge-to-edge alignment to provide high, short circuit strength. Insulated main bus with isolated vertical bus is optional. General Control and Communication Wiring Standard control and communication wiring is #14 AWG extra-flexible, stranded copper type SIS. Terminations are made with compression-type, insulated terminals. Control and communication wiring is installed and accessed from the front of the switchgear structure. Each breaker compartment has a dedicated horizontal and vertical wireway. For devices not having screw-type terminals, pressure terminals are used. Circuit Breaker Compartments Typical circuit breaker compartments include primary disconnects, drawout rails, secondary disconnects, vertical wireway, horizontal wireway and, if applicable, TOC switch operator, MOC switch operator and associated interlocks. Drawout rails allow the breaker to be withdrawn from the compartment without additional extensions or adapters. Up to six (2 sets of three) current transformers for metering or relaying can be mounted in each compartment. Insulation The insulation used is a UL recognized thermoset material that has excellent heat resistance, flame retardance, dimensional stability and low moisture absorption. A separate secondary disconnect access door that is supplied with each breaker can be used to mount a variety of auxiliary devices such as breaker control switches, indicating lights and pushbuttons. Vertical bus ratings available are 1600, 2000, 3200, 4000 and 5000 amperes continuous current. Horizontal bus ratings available are 1600, 2000, 3200, 4000, 5000 and 6000 amperes. A neutral bus is furnished when specified, and can be rated 1600, 2000, 3200, 4000, 5000 or 6000 amperes continuous current. 2 1 3 4 A standard copper ground bus extends through all sections. Cable lugs are mounted to the ground bus in each section. Standard short-circuit withstand (4 cycle) and short-time withstand (60 cycle) bus bracing is 100,000 amperes. Higher shortcircuit withstand bus bracings (150kA and 200kA) are available. Load side runbacks for feeder circuits are copper construction, are insulated with sleeve tubing in the main bus area, and are supported by high-strength bus bracing. 5 1 2 3 4 6 TOC Switch Operator Breaker Compartment Rear Barrier Secondary Disconnect Vertical Wireway 7 5 6 7 Interference Interlock Drawout Rails Primary Disconnect Circuit Breaker Cell Interior For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-44 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear Options without exposure to the elements. An access door equipped with an emergency bar release is located at each end of the aisle. The following features are standard with walk-in outdoor enclosures. (1) Space heaters in breaker compartment and bus compartment. (2) Screens and filters for exterior door ventilation louvers. (3) Incandescent lighting receptacle with three-way switch at each aisle access door. (4) Duplex receptacle with ground fault protection at each aisle access door. (5) Load center for power distribution to lights, receptacles, switches and heaters. For non walk-in outdoor enclosures, space heaters and screens/filters for ventilation louvering are standard with lighting, receptacles, switches and load centers offered as options. Side View In the walk-in outdoor enclosure a lighted, unobstructed service aisle is provided at the front of the switchgear allowing inspection and maintenance Rear View Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-45 SWITCHGEAR Test Set A portable breaker test set is available as an option and supports testing the full range of functions and protective settings supplied with the breaker trip unit. Metering and Auxiliary Compartments Compartments are available to house devices such as voltage transformers, metering, control power transformers, and supervisory devices. Instrument and Control Transformers Voltage transformers and control power transformers are mounted in auxiliary compartments. These transformers are protected by primary pull-out type current-limiting fuses and secondary fuses. Current transformers are normally mounted on the compartment primary disconnect studs where they are readily accessible. Miscellaneous ▪ Each switchgear lineup includes a breaker lifting device that is adjustable for use with Size II and Size III breakers ▪ An optional portable breaker hoist is available if the integrated breaker hoist and track is not specified ▪ A test cabinet is also available as an option. The test cabinet is wall mounted necessary equipment for testing electrically-operated breakers that have been removed from the breaker compartment. The test cabinet doesn't include or replace a breaker trip unit tester ▪ 4" high formed steel channel sills are available for indoor switchgear enclosures Outdoor Switchgear Type WL switchgear is available in two outdoor (NEMA 3R) enclosures. Walk-in and non walk-in versions are available to meet your particular application. For protection from snow, rain and other foreign matter, both outdoor enclosures rest on a six-inch high, formed steel base which provides rigid support and a tight bottom seal. A heavy duty protective undercoating is applied to the underside of all outdoor enclosures to protect against moisture and corrosion. Shielded ventilation housings permit proper air circulation while excluding dirt and foreign matter. 13 Siemens High Resistance Grounding System (1) The HRG section can be 22" or 32" wide. The HRG instrument compartment is 45" high and either 19" or 24" deep depending on whether the circuit breakers are fused. The HRG instrument compartment will house all of the high resistance grounding system components either on the door or in the device bucket except for the grounding resistors. (2) The grounding resistor assembly will mount in the rear cable compartment of the switchgear on the runback support posts. It will typically mount behind the HRG instrument compartment where it cannot interfere with feeder breaker runbacks. (3) In a typical Siemens HRG application with a close coupled main breaker section, a general purpose instrument compartment takes up the A compartment, the main breaker goes in the B compartment and the HRG instrument compartment takes up the C & D compartments. An alternate HRG main breaker section can have the HRG instrument compartment in the A & B compartments, main breaker in the C compartment and a general instrument compartment in the D compartment. Switchgear Mounted Hoist The integrally mounted hoist, standard on walk-in outdoor and optional on indoor switchgear enclosures, travels along rails on top of the switchgear to assist in breaker handling. TOC and MOC Switches The Truck Operated Cell (TOC) Switch provides interlocking control or remote indication of the breaker racking position. The cubicle mounted auxiliary switch or Mechanism Operated Cell (MOC) switch provides interlocking control or remote indication based on the main contact position (open or closed). Shutters These provide protection against accidental contact with primary disconnects in a compartment when the breaker is removed. Shutters automatically close when the breaker is withdrawn and are padlockable and field installable. Key Interlock This provides a mechanical means for operating circuit breakers and other devices only when predescribed conditions are met. General Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear Indoor Front Elevation View Dimensions Indoor Floor Plan and Cable Space Details 1.25 (32) typ. 4.42 (112) .75 (19) typ. .86 (22) 1.50 (38) .75 (19) typ. 5.86 (149) 7.88 (200) .86 (22) 4.82 (122) 13 B 4.00 (102) SWITCHGEAR Transformer Throat Liquid filled & outdoor dry type transformers only CL A Maximum available space in top or bottom of unit for customer's power cables 1.00 End Trim Panel (typ.) (25) Required on left and right end of switchgear lineup — adds 2” to total lineup width (4) Holes for .50 (12mm) Grade 5 anchor bolts Space for secondary leads from above 14.9 (378) 4.00 (102) 5.00 (127) 2.12 (54) 3.00 (76) 2.00 (51) Space for secondary leads from below D 7.00 (179) C 4.40 (112) 2.37 (60) 1.00 (25) 2.00 (51) 1.00 (25) W W = 22 (559) or 32 (813) A Equipment Depth 60" Non-Fused with (N, S, H or L-Rating Breakers) OR 65" Fused with (F-Rating Breakers) 70" Non-fused with (N, S, H or L-Rating Breakers) OR 75" Fused with (F-Rating Breakers) Direction of Cables B C D Below 21.50 (546) 13.88 (353) 32.59 (828) Above 21.25 (540) 18.88 (480) 37.59 (955) Below 31.50 (800) 13.88 (353) 32.59 (828) Above 31.25 (794) 18.88 (480) 37.59 (955) Below 41.50 (1054) 41.25 (1048) 36.50 (927) 36.25 (921) 13.88 (353) 32.59 (828) 18.88 (480) 37.59 (955) 80" Non-fused with (N, S, H or L-Rating Breakers) Above 80" Fused with (F-Rating Breakers) Below Above Note: Dimensions shown in inches and (mm). Reduce by 7.88" if upper neutral is present with cables above or if a lower neutral is present with cables below. Reduce by 4.00" if an 800-3200A breaker is located in the bottom compartment. Reductions per notes 1 & 2 are additive. Example: cables below + lower neutral + 2000A breaker in bottom compartment = B-11.88. Reduce cable space by 4.00" x 4.82" if Neutral Riser is present. (Consult Factory). 4.10 (104) if W=22; 4.60 (117) if W=32. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-46 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear Switchgear Depth Dimensional Information (Dimensions below are for internal frames – not total structure depth) ▪ Non-fused indoor – 60" standard, 70" and 80" optional ▪ Fused indoor – 65" standard, 75" and 80" optional ▪ Non-fused non-walk-in outdoor – 60" standard and 75" optional ▪ Fused non-walk-in outdoor – 65" standard and 75" optional ▪ Non-fused walk-in outdoor – 60" standard and 75" optional ▪ Fused walk-in outdoor – 65" standard and 75" optional ▪ Walk-in outdoor aisle is 42" deep ▪ Sections with cable connected main, tie and/or feeder breakers that are 3200 amp or greater must be minimum depth of 70" for unfused breakers and 75" for fused breakers. A Compartment B Compartment C Compartment D Compartment SWITCHGEAR Note 1 – If a 4000 amp feeder breaker is installed in Compartment C, Compartment D must be a Blank or Instrument Compartment. Note 2 – If a 4000 amp breaker is installed in Compartment B, Compartment A must be a Blank or Instrument Compartment. Note 3 – Contact factory for application guidelines related to this design. Note 4 – If a 3200 amp breaker is installed in Compartment B, the middle level through bus is not available. Note 5 – If a 3200 amp breaker is installed in Compartment D, the lower level through bus is not available. Note 6 – If incoming is bottom, feeder breakers can mount in compartments A and/or B. Note 7 – If a 3200 amp breaker is installed in Compartment B, Feeder Breaker in Compartment A is limited to 1600 amp. Note 8 – If a 3200 amp breaker is in Compartment BC, the maximum breaker in Compartment A is 1600 amp and if a 4000 amp breaker is in Compartment BC, the maximum breaker in Compartment A is 800 amp. Section Compartment Arrangement 13 General Notes: ▪ A blank/instrument compartment can always be substituted for a breaker compartment ▪ Any 22" wide section can be 32" wide if more conduit working room is needed ▪ For bus duct connections – if incoming is top, Compartment A must be blank/instrument, if incoming is bottom, Com-partment D must be blank/instrument ▪ Bused transition section is 22" wide ▪ For close coupled transformer connections, Compartment A must be blank/instrument ▪ Utility metering is always in a separate section. Section width is dependent on utility Selection Main Sections – Non-Fused Breakers Blank or Instrument Compartment Feeder Breaker 800, 1600, 2000 Blank or Instrument Compartment Blank or Instrument Compartment Blank or Instrument Compartment Main Breaker 800, 1600, 2000, 3200 Feeder Breaker 800, 1600, 2000, 3200 Blank or Instrument Compartment Main Breaker 4000, 5000 Blank or Instrument Compartment Feeder Breaker 800, 1600, 2000, 3200 Main Breaker 800, 1600, 2000, 3200 Main Breaker 800, 1600, 2000, 3200 Feeder Breaker 800,1600, 2000, 3200, 4000 Main Breaker 4000, 5000 Feeder Breaker 800, 1600, 2000 Blank or Instrument Compartment Feeder Breaker 800, 1600, 2000 Feeder Breaker 800,1600, 2000 22 in. (559 mm) 22 in. (559 mm) 22 in. (559 mm) 32 in. (813 mm) Refer to Note 1 Refer to Note 1 Refer to Note 6 Feeder Breaker 800, 1600, 2000 32 in. (813 mm) Main Sections – Fused Breakers Blank or Instrument Compartment Blank or Instrument Compartment Blank or Instrument Compartment Main Breaker 800, 1600, 2000 Blank or Instrument Compartment Feeder Breaker 800, 1600, 2000 Main Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 22 in. (559 mm) 22 in. (559 mm) 32 in. (813 mm) Blank or Instrument Compartment Main Breaker 3200, 4000 Main Breaker 5000 32 in. (813 mm) For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-47 Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear Selection Tie Sections – Non-Fused Breakers Feeder Breaker 800, 1600, 2000 13 Feeder Breaker 800,1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800,1600, 2000 Tie Breaker 800, 1600, 2000, 3200 Feeder Breaker 800, 1600, 2000 Tie Breaker 4000 Feeder Breaker 800, 1600, 2000, 3200, 4000 Feeder Breaker 800, 1600, 2000, 3200 Tie Breaker 800, 1600, 2000, 3200 Feeder Breaker 800,1600, 2000, 3200, 4000 Refer to Note 7 SWITCHGEAR Tie Sections – Fused Breakers Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Tie Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Tie Breaker 4000, 5000 Feeder Breaker 800, 1600, 2000 Tie Breaker 800, 1600, 2000 Feeder Breaker 800,1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 32 in. (813 mm) 22 in. (559 mm) 22 in. (559 mm) 32 in. (813 mm) Refer to Note 2 Refer to Note 2 and Note 4 Refer to Note 1 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800,1600, 2000 22 in. (559 mm) 22 in. (559 mm) 32 in. (813 mm) Refer to Note 1 Feeder Breaker 800, 1600, 2000 Main Breaker 800, 1600, 2000, 3200 Blank or Instrument Compartment Feeder Breaker 800 Tie Breaker 800, 1600, 2000, 3200 Main Breaker 800, 1600, 2000 Tie Breaker 800, 1600, 2000, 3200 Main Breaker 800, 1600, 2000, 3200 Feeder Breaker 800, 1600, 2000 22 in. (559 mm) Tie Breaker 3200, 4000 Feeder Breaker 800 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Main Breaker 4000 Tie Breaker 4000 Main Breaker 800, 1600, 2000 Tie Breaker 800, 1600, 2000 Tie Breaker 800, 1600, 2000 Tie Breaker 4000 Main Breaker 4000 Tie Breaker 800, 1600, 2000 Main Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Main Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 22 in. (559 mm) 22 in. (559 mm) 32 in. (813 mm) 32 in. (813 mm) 22 in. (559 mm) 22 in. (559 mm) Refer to Note 7 Feeder Sections – Non-Fused Breakers Feeder Breaker 800, 1600, 2000 Blank or Instrument Compartment Blank Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000, 3200 Feeder Breaker 800, 1600, 2000 Feeder Breaker 4000, 5000 Feeder Breaker 4000, 5000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000, 3200 Feeder Breaker 4000, 5000 Feeder Breaker 4000 Feeder Breaker 800, 1600, 2000, 3200 Feeder Breaker 800, 1600, 2000, 3200 Blank or Instrument Compartment Blank or Instrument Compartment Feeder Breaker 800, 1600, 2000, 3200 32 in. (813 mm) 32 in. (813 mm) 32 in. (813 mm) Refer to Note 4 Refer to Note 5 Blank or Instrument Compartment Tie Breaker 5000 32 in. (813 mm) Feeder Sections – Fused Breakers Feeder Breaker 800, 1600, 2000 22 in. (559 mm) Refer to Note 8 Main and Tie Sections – Fused Breakers Main and Tie Sections – Non-Fused Breakers Blank or Instrument Compartment Feeder Breaker 800, 1600 Refer to Note 5 Feeder Breaker 800, 1600 Blank or Instrument Compartment Feeder Breaker 3200 Feeder Breaker 4000 Blank or Instrument Compartment Feeder Breaker 5000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 Feeder Breaker 800, 1600, 2000 22 in. (559 mm) 32 in. (813 mm) 32 in. (813 mm) 32 in. (813 mm) For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-48 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Low Voltage Switchgear Type WL Circuit Breakers Rogowski Coil CT Technology Electronic Trip Unit Selection Criteria for WL Circuit Breakers The basic criteria for selecting circuit breakers is: Maximum Available Short Circuit at the installation point. This value determines the short circuit current interrupting rating or short circuit current withstand rating of the circuit breaker. Rated Current In which is to flow through the respective circuit breaker continuously. This value may not be greater than the maximum rated current of the circuit breaker. The rated current for the WL is determined by the rating plug, up to the maximum frame rating. Ambient Temperature of the circuit breaker. This is usually the temperature inside the cubicle. Design of the circuit breaker. Protective Functions of the circuit breaker. These are determined by the selection of the appropriate trip unit. Dynamic Arc-Flash Sentry (Patent Pending) A unique feature of the WL trip unit allows the system designer to achieve lower levels of arc flash energy and delayed tripping for selective trip coordination purposes. Rating Plug The Rating Plug is a replaceable module that enables users to reduce the rated device current for optimum adaptation to the system; e.g., during startup of a plant section. The Rating Plug should be selected so that it corresponds to the rated current of the system. Switch-selectable I2t or I4t Characteristic Curve Improved Overload Protection. The best possible protection is assured when all protective devices in the system are optimally coordinated. To achieve optimum selectivity and coordination, the long-time characteristic can be switched between l2t and l4t, to improve coordination with fuses or inverse relays. Switchable Parameter Sets To allow the protection to adapt to changes in system needs such as switching between utility and generator feeds, WL Circuit Breakers support ETUs with two independent parameter sets. Switching between the parameter sets occurs in less than 100 ms and can be done remotely or via a contact input to an optional CubicleBUS module. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-49 SWITCHGEAR Coil and Integrator: The combination of a coil and an integrator provides an exceptionally versatile current-measuring system which can be designed to accommodate a vast range of frequencies, current levels and conductor sizes. The output is independent of frequency, has an accurate phase response and can measure complex current waveforms and transients. Linearity: One of the most important properties of a Rogowski coil measuring system is that it is inherently linear. The coil contains no saturable components and the output increases linearly in proportion to current right up to the operating limit determined by voltage breakdown. The integrator is also inherently linear up to the point where the electronics saturates. Linearity makes Rogowski coils easy to calibrate because a transducer can be calibrated at any convenient current level and the calibration will be accurate for all currents including very large ones. Also, because of their linearity, the transducers have a very wide dynamic range and an excellent transient response. Coil Winding With a Rogowski coil it is important to ensure that the winding is as uniform as possible. A non-uniform winding makes the coil susceptible to magnetic pickup from adjacent conductors or other sources of magnetic fields. We have developed special machines for making accurate windings. Coils come in a range of styles including rigid and flexible coils but we have developed several other variations to meet specific needs. Output Indication The output from the integrator can be used with any form of electronic indicating device that has an input impedance greater than about 10kohm such as a voltmeter, oscilloscope, transient recorder or protection system. Split Coils Some designs of coil can be fitted on the conductor without the need to disconnect the conductor. Most flexible coils can be fitted this way and it is also possible to build split rigid coils. Split iron-cored devices such as current transformers are subject to appreciable amplitude and phase errors if the halves are misaligned by even a small amount. Rogowski coils do not have this problem. Misalignment of the joining faces of a split Rogowski coil has only a small effect on the amplitude and no effect on the phase. 13 A Rogowski coil is an ‘air-core’ toroidal coil placed round the conductor. The alternating magnetic field produced by the current induces a voltage in the coil which is proportional to the rate of change of current. The direct output from the coil is given by Vout=M dI/dt Where M is the mutual inductance of the coil and dI/dt is the rate of change of current. To complete the transducer the voltage is integrated electronically so that the output from the integrator is a voltage that accurately reproduces the current waveform. General Low Voltage Switchgear Type WL Circuit Breakers Selection SWITCHGEAR 13 Trip Unit Functions Basic Protective Functions Long-time overcurrent protection Short-time delayed overcurrent protection Instantaneous overcurrent protection Neutral protection Ground fault protection L S I N G ETU725 ETU727 ETU745 ETU748 ETU755 ETU776 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 -- 쏹 쏹 --- 쏹 쏹 쏹 쏹 쏹 쏹 ------- 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 -- 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 -- 쏹 쏹 -- -------- 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 --- --- 쏹 쏹 쏹 쏹 -- -- 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 쏹 -- -- ------- ------- ----- 쏹 쏹 쏹 ---- -- 쏹 쏹 쏹 쏹 쏹 -- -- --- 쏹 -- -- ----- ----- 쏹 쏹 쏹 쏹 Additional Functions Selectable neutral protection Defeatable short-time delay Defeatable instantaneous protection Selectable thermal memory Zone selective interlocking Selectable I2t or fixed short-time delay Adjustable instantaneous pick-up Selectable I2t or I4t long-time delay Adjustable short-time delay and pick-up Selectable and adjustable neutral protection Dual protective setting capability (DAS)* Extended instantaneous protection ��� Parameterization and Displays Parameterization by rotary switches (10 steps) Parameterization by communication (absolute values) Parameterization by menu/keypad (absolute values) Remote parameterization of the basic functions Remote parameterization of the additional functions Alphanumeric LCD Graphical LCD Metering Function Metering function Plus -- Communication CubicleBUS Communication via PROFIBUS-DP Communication via the MODBUS Communication via the Ethernet (BDA) standard -- not available optional * DAS- Dynamic Arc Flash Sentry, Siemens patent pending protective feature 쏹 ��� Fixed short-time delay only For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. 13-50 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Low Voltage Switchgear Type WL Circuit Breakers General WL Communication Overview Connection Diagram 1 Breaker Data Adapter 13 13 (BDA) WinPM.Net Server 2 Browser-capable input and output device (e.g. notebook) WinPM.Net Web Client Ethernet / Internet / Intranet 3 WL Circuit Breaker 4 COM 16 MODBUS (BSS) 6 Electronic Trip Unit MODBUS Master PLC or Supervisory Software 9510 Meter* (Ethernet Gateway) Optional 7 Metering function PLUS 8 Zone Selective MODBUS 8 9 10 11 12 SWITCHGEAR 5 Breaker Status Sensor 13 Ethernet module or COM 15 PROFIBUS module 15 BDA Plus* 14 Interlocking (ZSI) module 9 Digital output module with relay or optocoupler outputs 10 Digital output module with relay or optocoupler outputs, remotely configurable 11 Analog output module 12 Digital input module 4 2 5 1 6 BDA 7 3 WL Circuit Breaker with COM 16 * The Siemens BDA Plus or meters, 9330, 9350, 95/9610 can be used as a gateway to enable Ethernet communication to the WL Circuit Breaker. 13 WinPM.Net on PC 14 PLC (e.g. SIMATIC S7) 15 BDA Plus Features ▪ Industry standard MODBUS or PROFIBUS communication available on all WL breakers from 200A to 5000A ▪ The high modularity of the WL Circuit Breakers and accessories allows simple retrofitting of all communication components ▪ The ability to connect additional input and output modules to the breakerinternal CubicleBUS of the WL opens up a range of opportunities to reduce econdary device count and wiring and to increase functionality implemented in switchgear ▪ Innovative software products for local configuration, operation, monitoring and diagnostics of WL Circuit Breakers using MODBUS, PROFIBUS or via Ethernet/Intranet/Internet ▪ Complete integration of WL Circuit Breakers in all Totally Integrated Power and Totally Integrated Automation Solutions Metering Function/Metering Function PLUS The integrated metering function can be installed on all ETU745, ETU748, ETU755, and ETU776 trip units and provides a viable alternative to external multi-function measuring instruments in many applications. Metering Function can measure the following: ▪ Currents ▪ Voltages ▪ Power ▪ Energy ▪ Power Factor ▪ Frequency All metered quantities are delivered as real time values with min/max recording. The metering module also contains additional alarm setpoint and protective relay functions (e.g. trip on overfrequency or undervoltage, and alarm on reverse power or over ampere demand). The Metering Function PLUS has two additional wave form buffers and supports harmonic analysis. With the two independent wave form buffers, the current and voltage waveforms can be recorded, and allows detailed diagnostic triggering on events. If the Metering Function /Metering Function PLUS is ordered together with the circuit breaker, it is already installed and ready for operation. As a retrofit part, the metering function is simply attached to the ETU and connected to the CubicleBUS. For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-51 Low Voltage Switchgear Arc Flash Solutions General Function Description objects can be detected at a range of 15 m, for example, to output a warning message (however, this is not safetyrelated). Flexibility already on board Mode of operation E Sc Reflection SF 3 SF 1 SF 4 SWITCHGEAR 13 SF 2 Dynamic Arc Flash Sentry (DAS) Laser Scanner Sensor SIGUARD laser scanners are optical distance sensors which detect any motion in a 190° working zone. By transmitting safe laser pulses and then evaluating every reflected pulse, they have everything safely in view. And when potentially hazardous situations do arise, they respond quickly and reliably. They can be simply programmed using either a PC or a laptop which means that they can be quickly and flexibly adapted to new requirements. Unified, integrated communications via standard fieldbuses can be implemented in a fail-safe fashion by transmitting safety-related and standard data together. This means that also with our SIGUARD laser scanners, you can enjoy the benefits of having just one bus coupling. SIGUARD laser scanners LS4 – the advantages at a glance: ▪ Hazardous areas can be contactlessly and reliably secured with devices which can be universally used: on machines, production robots, conveyor systems, vehicles etc. ▪ Standard versions with fail-safe semiconductor outputs ▪ Safe direct connection to AS-Interface Safety at Work ▪ User-friendly version with PROFIBUS PROFIsafe connection ▪ When scanners are replaced, parameters are automatically transferred via PROFIBUS ▪ Category 3 according to EN 954-1 ▪ Up to 4 personnel protective and warning field pairs which can be freely set ▪ Protective field with max. 4 m radius for personnel safety ▪ Extremely compact design ▪ Low current drain (approx. 300 mA) 13-52 The SIGUARD laser scanner LS4 is a scanner which optically and contactlessly scans areas – and which is predominantly used for personnel protection. The laser scanner generates a continuous train of bundled light pulses using a laser diode and an optical system. An integrated rotating mirror distributes these light pulses over the complete working area. If objects or persons enter this field, then the scanner evaluates the reflected light pulses and, using the light propagation time, continually calculates the precise position coordinates. If the defined personnel protective field is violated, then it brings the machine to an immediate stop. 0.36° – 5° SIGUARD laser scanners can be flexibly adapted to every requirement using four variable protective field pairs for personnel protection and warning fields. These protective field pairs can be simply set at the PC. The SIGUARD laser scanner can be used on stationary machines and systems, but it can also be used for mobile applications mounted on vehicles, driverless transport systems or trolleys. This means, for example, that various operating areas of a robot can be secured where the laser scanner consecutively scans the different areas. Using four programmable protective fields, driverless transport systems can be secured e.g., for fast travel, slow travel, lefthand and righthand curves. Software for every application 185° The operating range of SIGUARD laser scanners LS4 extends over 190° and is subdivided into angular segments of 0.36°. The scanning rate is 25 scans per second which means that a light pulse is transmitted every 40 ms into every segment. A special algorithm ensures that objects larger than 70 mm – this corresponds to the scanner resolution – are reliably detected. However, it also ensures that dust and other disturbing effects do not have a negative impact on the availability of the system. Personnel protective field 4 m Warning field Working area Only personnel protective fields are shown 15 m 50 m SIGUARD laser scanners LS4 detect persons – even when they are wearing dark clothing – in a safety-related fashion up to 4 meters away. Persons and Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog It is extremely easy to precisely set the laser scanner thanks to the LS4soft PC operator software. The following functions are integrated: ▪ Protective fields can be easily configured using either a PC or laptop ▪ Additional functions such as protective field changeover, restart inhibit etc. can be configured using a software assistant ▪ Extensive range of displays – e.g., defined protective fields, actual scan contour, system settings etc. ▪ Safe access protection using passwords with various authorization stages ▪ LS4soft can run under Microsoft Windows 95/98/2000/NT/XP Low Voltage Switchgear Arc Flash Solutions General Connection Examples + 24V 0V PE AS-Interface Safety at Work 1,25 A mT 24 V AS-Interface auxiliary voltage or 24 V DC Evaluation unit or fault-tolerant PLC Optional: Local button for restart Protective field 1–4 Addressing socket 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 13 X1 SWITCHGEAR SIGUARD laser scanner LS4 SIGUARD laser scanner LS4 SIGUARD laser scanner “Standard” with protective field changeover and start button ▪ Start button for manual restart directly at the scanner (connection 2) ▪ Alarm output at connection 5 (e.g., warning lamp) ▪ Protective field changeover at connections 4, 6, 7 and 8 ▪ Safety-related processing of the safe outputs (connections 11 and 12) through an evaluation unit or fault-tolerant PLC PROFIBUS PROFIBUS or terminating resistor at the end node 24 V DC +24V + 24V 0V PE SIGUARD laser scanner AS-Interface ▪ Directly connected to AS-Interface Safety at Work ▪ Safety-related shutdown using the safety monitor ▪ Protective field changeover as for the standard scanner ▪ A local button can be optionally connected for manual restart ▪ All of the connections are established through M12 connectors 6,3 AF 1,25 AmT k4 Safety output Optional: Local button for restart 6,3 AF 1 AT Contactor monitoring k5 A1(L+) S1 1 S33 S34 S35 S31 S22 2 3 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 CH1 K1 SIGUARD 3RG7847-4BB K2 A2(L- S21 S12 1 K4* SIGUARD laser scanner LS4 SIGUARD Laserscanner LS4 N.O. N.O. CH2 2 3 K5* 0V *provide suitable spark quenching SIGUARD laser scanner “Standard” with 3RG7847-4BB evaluation unit ▪ Start button for manual restart directly at the scanner (connection 2) ▪ Permanently set protective field pair 1 (24 V permanently connected to connection 4) SIGUARD laser scanner PROFIBUS ▪ Directly connected to PROFIBUS ▪ The shutdown signal is safely transferred via the PROFIBUS PROFIsafe profile ▪ Safe protective field changeover also via PROFIBUS ▪ Laser scanners can be quickly replaced thanks to the automatic parameter transfer ▪ A local button can be optionally connected for manual restart ▪ All of the connections are established through M12 connectors For more information, please visit http://automation.usa.siemens.com/consultant/ or contact your local sales office. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 13-53 SWITCHGEAR 13 Notes 13-54 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14SPEEDFAX TM 2007-2008 Busway Systems Contents 14-4 14-5 – 14-7 14-8 – 14-10 14-11 – 14-12 14-13 14-14 14-15 – 14-16 14-17 14-18 14-19 – 14-20 14-21 – 14-22 14-23 14-24 – 14-25 14-26 – 14-27 14-28 – 14-29 14-30 – 14-31 14-32 14-33 14-34 14-35 14-36 14-37 14-38 – 14-39 14-40 14-41 14-42 – 14-43 14-44 14-45 14-46 14-47 14-48 14-49 14-50 14-51 14-52 14-53 14-54 14-55 14-56 14-57 – 14-58 14-59 14-60 – 14-61 14-62 BUSWAY SYSTEMS Residential Commercial Industrial 14-2 14-3 14 General Pricing Notes Busway Selector Sentron® Busway Catalog Numbering System Busway, Aluminum Busway, Copper Busway, Accessories Sentron® Bus Plugs Catalog Numbering System Fusible Bus Plugs Circuit Breakers Sentron® Miscellaneous Sentron® Cubicles Meter Center Taps Sentron® General & Technical Information National Electric Code—References Sentron Busway Overview Sentron Bus Plug Overview Technical Data Straight Sections - Plug-In, Riser & Feeder Elbows Offsets & Combinations Tees End Tap Boxes Center Tap Boxes In-Line Disconnect Cubicles & Expansion Fittings Reducers & Phase Rotation Fittings Service Heads Hangers Hangers & End Closers Roof & Wall Flanges Flanged Ends Panelboards & Meter Center Modules Molded Case Circuit Breaker Cubicles with Meter Tap Stack Provisions Installation & Application Information Sentron Busway Quick Reference XJ-L, Plug-in Busway, Copper Busway, Accessories BD, Plug-in Busway, Aluminum and Copper Busway, Accessories XL-U, Plug-In, Feeder Busway, Aluminum Busway, Accessories Busway, Copper Busway, Accessories Bus Plugs XJ-L XL-X, XL-U, BD Cubicles XL-X, XL-U, BD Mobile Industrial Trol-E Duct 2 and 3-Pole Duct, Accessories 4-Pole Duct, Accessories Busway Systems Overview BUSWAY SYSTEMS 14 Pricing Notes A. Footage Pricing 1. Sentron and XL-U base pricing is listed on a per foot charge. When calculating the footage charge, fractions are figured to the next larger number of whole feet (i.e., a linear run totaling 66'3" would be priced at 67 feet. 2. BD, XJ-L and ITD base pricing is listed on a per section charge. B. Accessories Some busway accessories are listed as complete device prices while others are listed under accessory charges. 1. Complete device price includes all material and accessory charges for a standard device. (Busway footage included if applicable). 2. Accessory Charge includes fabrication and any miscellaneous fittings for the standard device. (No busway footage included). C. End Cable Tap Boxes are designed to be installed at the beginning or end of a busway run. The busway rating determines the tap box list price. Mechanical lugs are standard. For compression lugs add 30% to tap box list price. D. Elbows with an angle other than 90 degrees, the accessory charge is to be doubled. E. Flange Ends (Switchboard Connections / Stubs) accessory prices are for connection to Siemens equipment. For connection to other manufacturer’s equipment, multiply the flange end list price by 2.5. Standard list price includes eight inches of bus extension into equipment from mounting flange, if more than 8 inches required consult factory for pricing. Sentron Switchboards can be assembled with the Busway Flanged End pre-installed, eliminating the labor to connect the Busway to the switchboard at the job site. F. Service Heads are specially constructed tap boxes suitable for outdoor use and are equipped to accept service cables through a removable insulated bottom plate. The busway should be priced through the end of the run. 14-2 General G. Phase Transpositions can be built into a busway section to provide better voltage balance on long runs. To price, use the “Expansion Section” accessory charge for the appropriate ampere rating. H. Hangers Sentron and XL-U busway are UL listed for standard hanger spacing of ten feet (on center). Purchasing busway hangers for horizontal installations is optional. Unistrut/ Kindorf is commonly used by contractors as an approved alternative. Two hangers are furnished free of charge with every straight section of BD and XJ-L. For ITD refer to pricing section. Self compensating “Spring” hangers required for vertical installations are designed to be field installed by the installer and are shipped separately. These are also used as intermediate supports where floor-to-floor height is greater than 16 feet. I. Ceiling, Floor And Wall Flanges are used when busway passes through a floor or wall and are intended to cover that portion of the opening around the outside of the busway. They are not to be used to support the busway. J. Reducers price is determined by the rating of the larger busway. Fused reducers do not include fuses. K. Special Paint — Busway Sections, Accessories And Bus Plugs Standard finish is ASA #61 light gray. For other than standard color, add 20% and consult factory for availability. L. For Silver Finishing of Copper Bus Bars, add 10%. M. Roof Flanges are specially constructed collars and plates built onto a section of 3R busway which passes through a flat or angled roof. Roof pitch must be given for angled roof. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog N. Circuit Breaker Type Bus Plugs for Sentron Busways are priced as “complete devices” with circuit breakers factory installed. Circuit Breaker plugs for XJ-L, BD, XL-U and XL-X busways are priced “enclosure only.” When ordered with breaker, standard procedure is to individually ship both the enclosure and circuit breaker. When ordering bus plugs with breaker factory installed, add enclosure and breaker prices together and add 20% to the total, specify when ordering and allow time for assembly. O. Fusible Type Bus Plugs do not include fuses. Adapter kits for Class R, T & J fuses are available for field installation. P. Cubicle list prices include labor and material for a single frame device with enclosure including line side internal bussing for connection to busway and protective device. Fuses and load side bussing are not included in the base price. Q. Sentron Busway has been tested in accordance with UL1479 and offers a certified two hour fire rating for gypsum wall board construction, and a three hour fire rating for concrete slab or block penetrations. These ratings were achieved using standard busway installed with SpecSeal® sealant from Specified Technologies Inc. This material is available through Electrical Distribution. R. Refer to the following publications for additional technical information and physical parameters. Sentron Busway BUSA-05501 XL-U Busway 5.3.2 BD Busway BUSA-5331 XJ-L Busway BUPC-XJL-01 TROL-E-DUCT 5.2.1 Busway Systems Overview Selector Chart (100-6500 Ampere) I-T-E (then known as Bulldog Electric) was the first manufacturer to make a Busway System. Since its introduction in General 1932, Busway Systems have improved and expanded into several designs to meet the ever changing needs of the electrical industry. The Busway Selection Chart below will help you in selecting the proper product to fit your requirements. Busway Selector Chart 100-6500 Ampere Feature Ampere Rating AC Service 50-60 Hz 400Hz Voltage Construction Meets Electrical Standard Meets most applicable provisions of this foreign standard. BD Plug-in ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Consult ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ Industrial Trol-E-Duct ⻫ ⻫ ⻫ BUSWAY SYSTEMS Use 100 150 200 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000 6000, 6500 Copper Aluminum Indoor Outdoor 2W 1Ø3W 3Ø3W 3Ø4W FN 3Ø4W 200% N 600 volts or less Ventilated Non-Ventilated UL 857 NEMA BU1 CSA/CUL C22.2 NO 27 ANCE NMX-J-148ANCE 60439-1 1993 IEC 60439-2 1993 XJ-L Plug-in 14 Conductor 600 Volts or Less Product Plug-in and Feeder Busway Sentron XL-U Plug-in/Feeder Plug-in Feeder ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ ⻫ factory for information. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-3 Sentron® Busway Systems Catalog Numbering System Selection Suffix part of Catalog Numbers S X 4 0 2 C 1 0 䊱 䊱 䊱 䊱 䊱 䊱 Sentron SX = US Lengths BUSWAY SYSTEMS 14 Configuration 3 = 3Ø, 3W 4 = 3Ø, 4W 100% Neutral 5 = 3Ø, 4W 200% Neutral Ampere Rating 02 = 225A 04 = 400A 06 = 600A 08 = 800A 10 = 1000A 12 = 1200A 13 = 1350A 16 = 1600A 20 = 2000A 25 = 2500A 30 = 3000A P L 0 6 䊱 䊱 䊱 䊱 Feeder Length in Inches, ex.: 2'3" = 027 Feeder lengths available from 2'0" (024 Inches) up to 10'0" (120 inches) Plug-in L Length 04 = 4'0" 06 = 6'0" 08 = 8'0" 10 = 10'0" Riser I Length 04 = 4'0" 06 = 6'0" 08 = 8'0" 10 = 10'0" Elbows S = Stack햹 L = 90° O = Odd degree angle햶 32 = 3200A 40 = 4000A 50 = 5000A햲 Bus Bar Material C = Copper M = 1000 Amps/In2 Copper A = Aluminum L = 750 Amps/In2 Aluminum Ground 1 = Integral (Housing) 2 = Internal Bus Bar 햳 3 = Isolated Ground 햳 Tees Offsets Combinations E F O Edge Up Down Flat Right Left Edge Up Down Flat Right Left Edge Up Down Flat Right Left Edge Up Edge Down Edge Up Edge Down Flat Left Flat Left Flat Right Flat Right Flat Left Flat Left Flat Right Flat Right Edge Up Edge Down Edge Up Edge Down IP Rating 0 = IP40햷 4 = IP55햷 6 = IP66햴햸햹 9 = NEMA 3R햵햸햹 EXpansion Fittings P F T Center Cable Tap Boxes T B 햲 Copper Standard EXpanded End Cable Tap Boxes T Vertical Horizontal Standard EXpanded End Closers C L S FlanGe Roof Wall F L Joint Stacks Standard Isolation S T SerVice Heads 1 = 1-Phase 3 = 3-Phase T = Throat Tranformer Reducers Fused Non-fused R R F N Flanged End E = Int’l Standard N R = U.S. Standard N O = Other D D Transposition R only 햳 Copper or aluminum ground bar 햴 IEC Markets 햵 NEMA Markets 햶 For odd degree angle (other than 90°) specify the degree angle of the turn. 햷 Indoor only (Plug-in and Feeder) 햸 Outdoor use (Feeder only) 햹 Elbow Stack (IP40 and IP55 only) • Catalog Numbers for Hangers can be found on page 14-12. • Specials must be ordered by description (drawing must be included). Contact factory for pricing. 14-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Utility H Florida Pwr/Light Houston Pwr/Light Commonwealth ED Pacific Gas/Electric Detroit Edison Other PG = Phase & Ground PO = Phase only GO = Ground only Sentron® Straight Section Busway Aluminum (225 – 1000 Ampere) Selection 225A Aluminum Basic Catalog Number SX302A1 Add Suffix To Basic Catalog Number 0F 4F 9F 0P 4P 0R 4R Busway Type Feeder IP40 Feeder IP55 Feeder 3R Plug-in IP40 Plug-in IP55 Riser IP40 Riser IP55 SX302A2 SX302A3 SX402A1 SX502A1 SX402A2 4-Pole Internal Ground SX502A2 4-Pole Internal Ground 200% Neutral 3-Pole Internal 3-Pole Ground List Price Per Foot $ 249.00 264.00 293.00 308.00 374.00 393.00 268.00 282.00 318.00 335.00 259.00 273.00 259.00 321.00 3-Pole Isolated Ground 4-Pole 4-Pole 200% Neutral 274.00 322.00 411.00 293.00 348.00 284.00 336.00 276.00 326.00 415.00 295.00 349.00 285.00 337.00 SX304A1 249.00 293.00 374.00 268.00 318.00 259.00 305.00 SX304A2 264.00 308.00 393.00 282.00 335.00 273.00 321.00 SX304A3 274.00 322.00 411.00 293.00 348.00 284.00 336.00 SX306A1 249.00 293.00 374.00 268.00 318.00 259.00 305.00 SX306A2 264.00 308.00 393.00 282.00 335.00 273.00 321.00 SX308A1 271.00 321.00 409.00 290.00 343.00 280.00 332.00 SX310A1 295.00 346.00 441.00 311.00 370.00 302.00 358.00 SX402A3 4-Pole Isolated Ground SX502A3 4-Pole Isolated Ground 200% Neutral 349.00 410.00 524.00 370.00 436.00 360.00 424.00 312.00 367.00 471.00 332.00 372.00 322.00 360.00 386.00 455.00 580.00 405.00 481.00 397.00 470.00 367.00 390.00 497.00 349.00 417.00 341.00 403.00 405.00 479.00 608.00 421.00 504.00 415.00 491.00 SX404A1 276.00 326.00 415.00 295.00 349.00 285.00 337.00 SX504A1 349.00 410.00 524.00 370.00 436.00 360.00 424.00 SX404A2 312.00 367.00 471.00 332.00 393.00 322.00 380.00 SX504A2 386.00 455.00 580.00 405.00 481.00 397.00 470.00 SX404A3 332.00 390.00 342.00 349.00 391.00 341.00 403.00 SX504A3 405.00 479.00 608.00 424.00 504.00 415.00 491.00 SX306A3 274.00 322.00 411.00 293.00 348.00 284.00 336.00 SX406A1 276.00 326.00 415.00 295.00 349.00 285.00 337.00 SX506A1 349.00 410.00 524.00 370.00 436.00 360.00 424.00 SX406A2 312.00 367.00 471.00 332.00 393.00 322.00 380.00 SX506A2 386.00 455.00 580.00 405.00 481.00 397.00 470.00 SX406A3 332.00 390.00 497.00 349.00 417.00 341.00 403.00 SX506A3 405.00 479.00 608.00 424.00 504.00 415.00 491.00 SX308A2 282.00 332.00 424.00 298.00 357.00 291.00 343.00 SX308A3 293.00 343.00 440.00 310.00 368.00 301.00 357.00 SX408A1 295.00 346.00 441.00 311.00 370.00 302.00 358.00 SX508A1 373.00 439.00 559.00 390.00 462.00 383.00 451.00 SX408A2 333.00 391.00 500.00 352.00 417.00 342.00 404.00 SX508A2 410.00 484.00 617.00 429.00 510.00 420.00 497.00 SX408A3 353.00 417.00 529.00 370.00 415.00 360.00 429.00 SX508A3 431.00 510.00 646.00 449.00 533.00 440.00 521.00 SX310A2 315.00 370.00 471.00 332.00 393.00 324.00 383.00 SX310A3 333.00 393.00 502.00 352.00 418.00 342.00 405.00 SX410A1 336.00 395.00 503.00 353.00 420.00 343.00 408.00 SX510A1 424.00 500.00 636.00 441.00 524.00 433.00 512.00 SX410A2 379.00 448.00 572.00 398.00 471.00 389.00 459.00 SX510A2 467.00 552.00 702.00 484.00 575.00 477.00 564.00 SX410A3 403.00 472.00 604.00 420.00 497.00 410.00 484.00 SX510A3 490.00 579.00 735.00 508.00 604.00 498.00 591.00 400A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 800A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 1000A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Feeder or Plug-in Indoor Splash Proof IP40 IP55 Feeder Only Outdoor Discount Schedule BUSW NEMA 3R Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-5 BUSWAY SYSTEMS 600A Aluminum 14 Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Sentron® Straight Section Busway Aluminum (1200– 2000 Ampere) Selection 1200A Aluminum Basic Catalog Number SX312A1 Add Suffix To Basic Catalog Number 0F 4F 9F 0P 4P 0R 4R Busway Type Feeder IP40 Feeder IP55 Feeder 3R Plug-in IP40 Plug-in IP55 Riser IP40 Riser IP55 SX312A2 SX312A3 SX412A1 SX512A1 SX412A2 4-Pole Internal Ground SX512A2 4-Pole Internal Ground 200% Neutral 4-Pole 4-Pole 200% Neutral SX412A3 4-Pole Isolated Ground SX512A3 4-Pole Isolated Ground 200% Neutral 3-Pole Internal 3-Pole Ground List Price Per Foot $ 333.00 395.00 391.00 466.00 502.00 595.00 352.00 414.00 417.00 490.00 342.00 404.00 404.00 479.00 3-Pole Isolated Ground 456.00 541.00 687.00 473.00 564.00 466.00 552.00 459.00 542.00 689.00 477.00 565.00 467.00 554.00 579.00 684.00 865.00 596.00 708.00 587.00 697.00 518.00 611.00 772.00 535.00 636.00 528.00 624.00 637.00 753.00 957.00 655.00 772.00 646.00 766.00 548.00 648.00 819.00 565.00 672.00 556.00 659.00 SX313A1 398.00 467.00 596.00 415.00 492.00 405.00 480.00 SX313A2 398.00 467.00 596.00 415.00 492.00 405.00 480.00 SX313A3 518.00 614.00 788.00 535.00 637.00 528.00 625.00 SX413A1 521.00 615.00 788.00 539.00 639.00 529.00 627.00 SX513A1 656.00 772.00 988.00 673.00 803.00 666.00 788.00 SX413A2 587.00 696.00 881.00 605.00 718.00 596.00 706.00 SX513A2 722.00 850.00 1081.00 741.00 881.00 731.00 865.00 SX413A3 622.00 735.00 927.00 639.00 760.00 748.00 748.00 SX513A3 758.00 896.00 1129.00 772.00 912.00 763.00 912.00 SX316A1 466.00 549.00 699.00 483.00 574.00 473.00 562.00 SX316A2 534.00 629.00 803.00 552.00 655.00 543.00 642.00 SX316A3 603.00 711.00 896.00 618.00 735.00 610.00 722.00 SX416A1 604.00 714.00 912.00 621.00 737.00 611.00 727.00 SX516A1 760.00 896.00 1143.00 772.00 927.00 768.00 912.00 SX416A2 680.00 803.00 1019.00 698.00 834.00 689.00 819.00 SX516A2 834.00 988.00 1253.00 850.00 1019.00 850.00 1005.00 SX416A3 719.00 850.00 1081.00 737.00 881.00 729.00 865.00 SX516A3 881.00 1036.00 1314.00 896.00 1067.00 881.00 1050.00 SX320A1 570.00 672.00 850.00 586.00 697.00 577.00 684.00 SX320A2 637.00 753.00 957.00 655.00 772.00 646.00 766.00 SX320A3 706.00 834.00 1067.00 722.00 865.00 715.00 850.00 SX420A1 708.00 834.00 1067.00 727.00 865.00 717.00 850.00 SX520A1 896.00 1050.00 1329.00 912.00 1081.00 896.00 1067.00 SX420A2 803.00 943.00 1205.00 819.00 974.00 803.00 957.00 SX520A2 974.00 1160.00 1469.00 1005.00 1191.00 988.00 1174.00 SX420A3 974.00 1160.00 1469.00 1005.00 1191.00 988.00 1174.00 SX520A3 1019.00 1222.00 1545.00 1036.00 1236.00 1036.00 1222.00 668.00 788.00 1005.00 686.00 819.00 677.00 803.00 BUSWAY SYSTEMS 14 1350A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 1600A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 2000A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Feeder or Plug-in Indoor Splash Proof 14-6 IP40 IP55 Feeder Only Outdoor NEMA 3R Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW Sentron® Straight Section Busway Aluminum (2500 – 4000 Ampere) Selection 2500A Aluminum Basic Catalog Number SX325A1 Add Suffix To Basic Catalog Number 0F 4F 9F 0P 4P 0R 4R Busway Type Feeder IP40 Feeder IP55 Feeder 3R Plug-in IP40 Plug-in IP55 Riser IP40 Riser IP55 SX325A2 SX325A3 SX425A1 SX525A1 SX425A2 4-Pole Internal Ground SX525A2 4-Pole Internal Ground 200% Neutral 3-Pole Internal 3-Pole Ground List Price Per Foot $ 749.00 834.00 881.00 988.00 1129.00 1253.00 766.00 850.00 865.00 1005.00 759.00 834.00 896.00 988.00 3-Pole Isolated Ground 4-Pole 4-Pole 200% Neutral 912.00 1081.00 1376.00 927.00 1112.00 927.00 1098.00 912.00 1081.00 1376.00 927.00 1112.00 927.00 1098.00 SX330A1 896.00 1050.00 1345.00 912.00 1081.00 896.00 1067.00 SX330A2 957.00 1143.00 1452.00 988.00 1160.00 974.00 1160.00 SX330A3 1036.00 1222.00 1562.00 1050.00 1253.00 1050.00 1236.00 SX332A1 973.00 1143.00 1452.00 988.00 1174.00 973.00 1159.00 SX332A2 1081.00 1282.00 1623.00 1097.00 1298.00 1081.00 1298.00 SX340A1 1112.00 1329.00 1686.00 1129.00 1345.00 1129.00 1329.00 SX340A2 1314.00 1545.00 1963.00 1329.00 1576.00 1314.00 1562.00 SX425A3 4-Pole Isolated Ground SX525A3 4-Pole Isolated Ground 200% Neutral 1143.00 1360.00 1731.00 1160.00 1391.00 1160.00 1376.00 1036.00 1222.00 1545.00 1050.00 1253.00 1036.00 1236.00 1267.00 1500.00 1901.00 1284.00 1531.00 1267.00 1514.00 1098.00 1298.00 1638.00 1112.00 1314.00 1098.00 1298.00 1329.00 1562.00 1994.00 1345.00 1593.00 1329.00 1576.00 SX430A1 1036.00 1236.00 1562.00 1050.00 1253.00 1050.00 1236.00 SX530A1 1298.00 1545.00 1963.00 1314.00 1562.00 1314.00 1562.00 SX430A2 1174.00 1391.00 1762.00 1191.00 1407.00 1174.00 1407.00 SX530A2 1438.00 1700.00 2149.00 1452.00 1731.00 1438.00 1717.00 SX430A3 1236.00 1469.00 1855.00 1253.00 1483.00 1253.00 1483.00 SX530A3 1500.00 1777.00 2257.00 1514.00 1808.00 1514.00 1793.00 SX332A3 1310.00 1407.00 1793.00 1206.00 1438.00 1206.00 1423.00 SX432A1 1310.00 1423.00 1793.00 1206.00 1438.00 1206.00 1423.00 SX532A1 1654.00 1948.00 2458.00 1500.00 1793.00 1500.00 1793.00 SX432A2 1485.00 2374.00 2243.00 1361.00 1607.00 1345.00 1593.00 SX532A2 1422.00 1685.00 2133.00 1669.00 1978.00 1700.00 1963.00 SX432A3 1345.00 1593.00 2026.00 1437.00 1700.00 1437.00 1700.00 SX532A3 1715.00 2040.00 2582.00 1731.00 2071.00 1731.00 2056.00 SX340A3 1500.00 1777.00 2241.00 1514.00 1793.00 1500.00 1777.00 SX440A1 1500.00 1777.00 2241.00 1514.00 1793.00 1500.00 1777.00 SX540A1 1870.00 2226.00 2814.00 1886.00 2241.00 1886.00 2241.00 SX440A2 1686.00 1994.00 2535.00 1700.00 2025.00 1700.00 2009.00 SX540A2 2071.00 2443.00 3092.00 2087.00 2474.00 2071.00 2458.00 SX440A3 1777.00 2102.00 2675.00 1793.00 2133.00 1793.00 2118.00 SX540A3 2164.00 2566.00 3232.00 2180.00 2582.00 2164.00 2566.00 3000A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 4000A Aluminum Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Feeder or Plug-in Indoor Splash Proof IP40 IP55 Feeder Only Outdoor Discount Schedule BUSW NEMA 3R Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-7 BUSWAY SYSTEMS 3200A Aluminum 14 Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Sentron® Straight Section Busway Copper (225 – 1000 Ampere) Selection 225A Copper Basic Catalog Number Add Suffix To Basic Catalog Number 0F 4F 9F 0P 4P 0R 4R Busway Type Feeder IP40 Feeder IP55 Feeder 3R Plug-in IP40 Plug-in IP55 Riser IP40 Riser IP55 SX302C1 SX302C2 SX302C3 SX402C1 SX502C1 SX402C2 SX502C2 4-Pole Internal Ground 200% Neutral 3-Pole Internal 3-Pole Ground List Price Per Foot $ 380.00 430.00 446.00 503.00 571.00 642.00 401.00 452.00 476.00 533.00 390.00 441.00 461.00 520.00 3-Pole Isolated Ground 4-Pole 4-Pole 200% Neutral 4-Pole Internal Ground 478.00 561.00 717.00 499.00 591.00 489.00 578.00 479.00 565.00 719.00 500.00 592.00 490.00 579.00 606.00 714.00 906.00 627.00 741.00 616.00 728.00 542.00 639.00 812.00 561.00 668.00 550.00 652.00 SX304C1 380.00 446.00 571.00 401.00 476.00 390.00 461.00 SX304C2 430.00 503.00 642.00 452.00 533.00 441.00 520.00 SX304C3 478.00 561.00 717.00 499.00 591.00 489.00 578.00 SX404C1 479.00 565.00 719.00 500.00 592.00 500.00 579.00 SX504C1 606.00 714.00 906.00 627.00 741.00 616.00 728.00 SX404C2 542.00 639.00 812.00 561.00 668.00 550.00 652.00 SX504C2 668.00 787.00 1009.00 687.00 817.00 679.00 800.00 SX404C3 572.00 675.00 854.00 592.00 705.00 583.00 691.00 SX504C3 698.00 824.00 1043.00 719.00 854.00 709.00 840.00 SX306C1 380.00 446.00 571.00 401.00 476.00 390.00 461.00 SX306C2 430.00 503.00 642.00 452.00 533.00 441.00 520.00 SX306C3 478.00 561.00 717.00 499.00 591.00 489.00 578.00 SX406C1 479.00 565.00 719.00 500.00 592.00 490.00 579.00 SX506C1 606.00 714.00 906.00 627.00 741.00 616.00 728.00 SX406C2 542.00 639.00 812.00 561.00 668.00 550.00 652.00 SX506C2 668.00 787.00 1009.00 687.00 817.00 679.00 800.00 SX406C3 572.00 675.00 854.00 592.00 705.00 583.00 691.00 SX506C3 698.00 824.00 1043.00 719.00 854.00 709.00 840.00 SX308C1 417.00 490.00 625.00 435.00 517.00 428.00 503.00 SX308C2 476.00 556.00 709.00 493.00 584.00 483.00 571.00 SX308C3 530.00 624.00 794.00 548.00 650.00 537.00 637.00 SX408C1 531.00 625.00 797.00 549.00 652.00 539.00 639.00 SX508C1 669.00 788.00 1009.00 687.00 816.00 679.00 804.00 SX408C2 600.00 708.00 906.00 618.00 735.00 608.00 721.00 SX508C2 738.00 872.00 1112.00 740.00 906.00 747.00 888.00 SX408C3 634.00 749.00 957.00 652.00 775.00 642.00 762.00 SX508C3 773.00 906.00 1162.00 791.00 941.00 781.00 923.00 SX310C1 461.00 542.00 692.00 479.00 568.00 470.00 555.00 SX310C2 565.00 667.00 846.00 583.00 692.00 572.00 679.00 SX310C3 667.00 787.00 991.00 685.00 812.00 674.00 799.00 SX410C1 668.00 788.00 1009.00 686.00 816.00 675.00 804.00 SX510C1 841.00 991.00 1264.00 854.00 1025.00 850.00 1009.00 SX410C2 753.00 888.00 1128.00 773.00 923.00 762.00 906.00 SX510C2 923.00 1094.00 1386.00 941.00 1128.00 941.00 1112.00 SX410C3 797.00 941.00 1197.00 816.00 975.00 806.00 957.00 SX510C3 975.00 1145.00 1454.00 991.00 1180.00 975.00 1162.00 668.00 787.00 1009.00 687.00 817.00 679.00 800.00 SX402C3 4-Pole Isolated Ground 572.00 675.00 854.00 592.00 705.00 583.00 691.00 SX502C3 4-Pole Isolated Ground 200% Neutral 698.00 824.00 1043.00 719.00 854.00 709.00 840.00 BUSWAY SYSTEMS 14 400A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 600A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 800A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 1000A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Feeder or Plug-in Indoor Splash Proof 14-8 IP40 IP55 Feeder Only Outdoor NEMA 3R Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW Sentron® Straight Section Busway Copper (1200 – 2500 Ampere) Selection 1200A Copper Basic Catalog Number SX312C1 Add Suffix To Basic Catalog Number 0F 4F 9F 0P 4P 0R 4R Busway Type Feeder IP40 Feeder IP55 Feeder 3R Plug-in IP40 Plug-in IP55 Riser IP40 Riser IP55 SX312C2 SX312C3 SX412C1 SX512C1 SX412C2 4-Pole Internal Ground SX512C2 4-Pole Internal Ground 200% Neutral 3-Pole Internal 3-Pole Ground List Price Per Foot $ 598.00 703.00 704.00 829.00 906.00 1043.00 616.00 721.00 731.00 854.00 606.00 710.00 719.00 842.00 3-Pole Isolated Ground 4-Pole 4-Pole 200% Neutral 805.00 957.00 1214.00 823.00 975.00 812.00 957.00 806.00 957.00 1214.00 824.00 975.00 816.00 957.00 SX313C1 668.00 788.00 1009.00 686.00 816.00 675.00 804.00 SX313C2 781.00 923.00 1162.00 799.00 957.00 791.00 941.00 SX313C3 888.00 1060.00 1333.00 906.00 1078.00 906.00 1078.00 SX316C1 761.00 906.00 1145.00 779.00 923.00 771.00 906.00 SX316C2 906.00 1060.00 1351.00 923.00 1094.00 906.00 1078.00 SX320C1 975.00 1145.00 1454.00 991.00 1162.00 975.00 1162.00 SX325C1 1231.00 1470.00 1864.00 1249.00 1488.00 1249.00 1470.00 SX412C3 4-Pole Isolated Ground SX512C3 4-Pole Isolated Ground 200% Neutral 1009.00 1197.00 1523.00 1025.00 1231.00 1025.00 1214.00 906.00 1078.00 1368.00 923.00 1094.00 923.00 1094.00 1112.00 1317.00 1675.00 1128.00 1351.00 1128.00 1333.00 957.00 1128.00 1436.00 975.00 1162.00 975.00 1145.00 1162.00 1386.00 1744.00 1180.00 1401.00 1180.00 1401.00 SX413C1 888.00 1060.00 1351.00 923.00 1078.00 906.00 1078.00 SX513C1 1128.00 1333.00 1693.00 1145.00 1351.00 1128.00 1351.00 SX413C2 1009.00 1197.00 1523.00 1025.00 1214.00 1025.00 1214.00 SX513C2 1231.00 1470.00 1864.00 1264.00 1488.00 1249.00 1488.00 SX413C3 1060.00 1264.00 1607.00 1078.00 1282.00 1078.00 1282.00 SX513C3 1299.00 1538.00 1949.00 1317.00 1556.00 1299.00 1556.00 SX316C3 1025.00 1214.00 1556.00 1043.00 1249.00 1043.00 1231.00 SX416C1 1025.00 1231.00 1556.00 1060.00 1249.00 1043.00 1231.00 SX516C1 1299.00 1538.00 1949.00 1317.00 1556.00 1299.00 1556.00 SX416C2 1162.00 1386.00 1744.00 1180.00 1401.00 1180.00 1386.00 SX516C2 1436.00 1693.00 2138.00 1454.00 1727.00 1436.00 1710.00 SX416C3 1231.00 1454.00 1846.00 1249.00 1488.00 1249.00 1470.00 SX516C3 1488.00 1779.00 2240.00 1523.00 1796.00 1505.00 1779.00 SX320C2 1112.00 1317.00 1675.00 1128.00 1351.00 1128.00 1333.00 SX320C3 1264.00 1505.00 1899.00 1282.00 1523.00 1264.00 1505.00 SX420C1 1264.00 1505.00 1899.00 1282.00 1523.00 1282.00 1505.00 SX520C1 1591.00 1881.00 2377.00 1607.00 1915.00 1591.00 1881.00 SX420C2 1419.00 1693.00 2138.00 1454.00 1710.00 1436.00 1710.00 SX520C2 1744.00 2070.00 2618.00 1762.00 2103.00 1762.00 2086.00 SX420C3 1505.00 1779.00 2257.00 1523.00 1812.00 1523.00 1796.00 SX520C3 1830.00 2172.00 2737.00 1846.00 2189.00 1830.00 2172.00 SX325C2 1454.00 1710.00 2172.00 1470.00 1744.00 1454.00 1727.00 SX325C3 1660.00 1967.00 2481.00 1675.00 1983.00 1660.00 1967.00 SX425C1 1660.00 1967.00 2481.00 1675.00 1983.00 1660.00 1983.00 SX525C1 2070.00 2463.00 3113.00 2103.00 2481.00 2086.00 2481.00 SX425C2 1864.00 2207.00 2804.00 1881.00 2240.00 1881.00 2222.00 SX525C2 2291.00 2702.00 3421.00 2309.00 2737.00 2291.00 2720.00 SX425C3 1967.00 2344.00 2959.00 1983.00 2359.00 1983.00 2344.00 SX525C3 2394.00 2839.00 3591.00 2412.00 2857.00 2394.00 2857.00 1350A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 2000A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 2500A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Feeder or Plug-in Indoor Splash Proof IP40 IP55 Feeder Only Outdoor Discount Schedule BUSW NEMA 3R Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-9 BUSWAY SYSTEMS 1600A Copper 14 Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Sentron® Straight Section Busway Copper (3000 – 5000 Ampere) Selection 3000A Copper Basic Catalog Number SX330C1 Add Suffix To Basic Catalog Number 0F 4F 9F 0P 4P 0R 4R Busway Type Feeder IP40 Feeder IP55 Feeder 3R Plug-in IP40 Plug-in IP55 Riser IP40 Riser IP55 SX330C2 SX330C3 SX430C1 SX530C1 SX430C2 4-Pole Internal Ground SX530C2 4-Pole Internal Ground 200% Neutral 3-Pole Internal 3-Pole Ground List Price Per Foot $ 1505.00 1744.00 1779.00 2070.00 2240.00 2618.00 1523.00 1762.00 1796.00 2103.00 1505.00 1762.00 1796.00 2086.00 3-Pole Isolated Ground 4-Pole 4-Pole 200% Neutral 2001.00 2359.00 2994.00 2018.00 2394.00 2001.00 2377.00 2001.00 2377.00 2994.00 2018.00 2394.00 2001.00 2377.00 SX332C1 1660.00 1968.00 2463.00 1676.00 1984.00 1660.00 1968.00 SX332C2 1933.00 2291.00 2891.00 1950.00 2326.00 1950.00 2309.00 SX332C3 2207.00 2618.00 3318.00 2224.00 2652.00 2224.00 2634.00 SX340C1 1949.00 2326.00 2925.00 1967.00 2344.00 1967.00 2326.00 SX340C2 2291.00 2720.00 3439.00 2309.00 2754.00 2309.00 2737.00 SX350C1 2326.00 2754.00 3489.00 2344.00 2788.00 2326.00 2770.00 SX350C2 2754.00 3249.00 4123.00 2770.00 3284.00 2754.00 3267.00 SX430C3 4-Pole Isolated Ground SX530C3 4-Pole Isolated Ground 200% Neutral 2496.00 2959.00 3762.00 2531.00 2994.00 2514.00 2976.00 2257.00 2667.00 3370.00 2275.00 2702.00 2257.00 2685.00 2754.00 3267.00 4138.00 2770.00 3302.00 2770.00 3284.00 2377.00 2822.00 3558.00 2394.00 2839.00 2394.00 2839.00 2873.00 3421.00 4328.00 2907.00 3439.00 2891.00 3439.00 SX432C1 2207.00 2634.00 3318.00 2241.00 2652.00 2224.00 2634.00 SX532C1 2771.00 3284.00 4157.00 2789.00 3318.00 2789.00 3302.00 SX432C2 2497.00 2960.00 3729.00 2515.00 2995.00 2497.00 2976.00 SX532C2 3045.00 3610.00 4585.00 3063.00 3644.00 3063.00 3627.00 SX432C3 2634.00 3130.00 3935.00 2652.00 3147.00 2565.00 3130.00 SX532C3 3182.00 3781.00 4789.00 3216.00 3797.00 3199.00 3797.00 SX340C3 2633.00 3130.00 3968.00 2651.00 3147.00 2651.00 3147.00 SX440C1 2633.00 3130.00 3968.00 2667.00 3165.00 2651.00 3147.00 SX540C1 3302.00 3917.00 4959.00 3317.00 3951.00 3317.00 3934.00 SX440C2 2976.00 3523.00 4464.00 2994.00 3558.00 2976.00 3541.00 SX540C2 3643.00 4310.00 5457.00 3660.00 4344.00 3643.00 4328.00 SX440C3 3147.00 3728.00 4704.00 3165.00 3746.00 3147.00 3728.00 SX540C3 3797.00 4516.00 5713.00 3831.00 4533.00 3815.00 4533.00 SX350C3 3165.00 3762.00 4755.00 3180.00 3780.00 3180.00 3762.00 SX450C1 3165.00 3762.00 4755.00 3180.00 3780.00 3180.00 3762.00 SX550C1 3968.00 4704.00 5952.00 3986.00 4738.00 3968.00 4720.00 SX450C2 3575.00 4225.00 5355.00 3591.00 4260.00 3575.00 4242.00 SX550C2 4362.00 5183.00 6552.00 4379.00 5200.00 4379.00 5183.00 SX450C3 3762.00 4464.00 5644.00 3780.00 4499.00 3780.00 4481.00 SX550C3 4567.00 5404.00 6842.00 4583.00 5439.00 4567.00 5422.00 BUSWAY SYSTEMS 14 3200A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 4000A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R 5000A Copper Basic Catalog Number Feeder IP40 0F Feeder IP55 4F Feeder 3R 9F Plug-in IP40 0P Plug-in IP55 4P Riser IP40 0R Riser IP55 4R Feeder or Plug-in Indoor Splash Proof 14-10 IP40 IP55 Feeder Only Outdoor NEMA 3R Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW Sentron® Busway Systems Busway Accessories Ampere Elbow Rating Stack Elbow Tee Suffix ES EL TE Selection Flanged End/ End Center Swbd. Tap Box Tap Box Conn. ET CT FE End XFMR Closure Throat EC VT XFMR Cable Tap 1-3 PH V3 XFMR Cable Tap 3-1 PH V1 Expansion Section XP Phase RotaReducer Reducer tion Fused Unfused Section RF RN PR Flanges Wall/ Floor GW Isolation Joint JI Roof Flange GR 3-Pole 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000 830. 830. 830. 968. 968. 968. 968. 968. 1106. 1106. 1106. 1166. 1289. 1289. 873. 873. 873. 1019. 1019. 1019. 1019. 1019. 1165. 1165. 1165. 1224. 1355. 1355. 1048. 1048. 1048. 1048. 1165. 1165. 1165. 1165. 1165. 1428. 1428. 1516. 1705. 1705. 1996. 1996. 1996. 2055. 2156. 2272. 2681. 2594. 2900. 3205. 3409. 3585. 3934. 4649. 1996. 1996. 1996. 2055. 2156. 2272. 2389. 2594. 2900. 3205. 3409. 3599. 3934. 4649. 918. 976. 1268. 1369. 1560. 1748. 1792. 2214. 2346. 2783. 3322. 4138. 4138. 4867. 218. 218. 218. 218. 220. 220. 228. 228. 228. 279. 279. 279. 279. 279. 4270. 4270. 4270. 4750. 5202. 5640. 6003. 6528. 7476. 8613. 10537. 11047. 12053. 14253. 976. 976. 976. 1035. 1093. 1136. 1194. 1253. 1443. 1719. 2025. 2113. 2302. 2638. 2797. 2797. 2797. 2988. 3147. 3322. 3396. 3555. 3963. 4357. 4750. 5013. 2451. 2809. 1486. 1486. 1486. 1777. 1952. 2113. 2302. 2477. 2929. 3396. 3905. 4226. 4867. 5741. 2097. 2097. 2097. 2404. 2725. 3249. 3454. 3905. 4562. 5538. 6398. 7010. 8234. 10085. 1106. 1106. 1106. 1268. 1443. 1719. 1836. 2069. 2404. 2929. 3396. 3716. 4357. 5333. 1486. 1486. 1486. 1777. 1952. 2113. 2302. 2477. 2929. 3396. 3905. 4226. 4867. 5741. 199. 199. 199. 199. 210. 210. 210. 218. 218. 224. 224. 224. 224. 224. 844. 844. 844. 844. 903. 903. 903. 931. 931. 961. 961. 961. 961. 961. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1180. 1180. 1180. 1238. 998. 998. 998. 1019. 1019. 1019. 1106. 1106. 1355. 1355. 1355. 1443. 1618. 1618. 1048. 1048. 1048. 1078. 1078. 1078. 1165. 1165. 1428. 1428. 1428. 1515. 1705. 1705. 1223. 1223. 1223. 1223. 1311. 1311. 1311. 1311. 1705. 1705. 1705. 1792. 1981. 1981. 2069. 2069. 2069. 2272. 2375. 2594. 2710. 3001. 3292. 3730. 4022. 4329. 4955. 5669. 2069. 2069. 2069. 2272. 2375. 2594. 2710. 3001. 3292. 3730. 4022. 4329. 4955. 5669. 976. 1005. 1297. 1413. 1705. 1821. 1908. 2230. 2564. 3104. 3672. 3979. 4591. 5815. 218. 218. 218. 218. 220. 220. 228. 228. 228. 279. 279. 279. 279. 279. 4794. 4794. 4794. 5450. 4022. 6178. 7243. 7957. 9268. 10945. 12446. 13510. 15623. 18816. 1035. 1035. 1035. 1136. 1194. 1253. 1385. 1443. 1719. 1952. 2244. 2360. 2579. 3046. 2797. 2797. 2797. 2988. 3147. 3322. 3396. 3555. 3963. 4357. 4750. 5013. 5552. 6353. 1777. 1777. 1777. 2069. 2302. 2638. 2827. 3424. 3730. 4342. 5042. 5480. 6353. 7621. 2171. 2171. 2171. 3046. 3571. 4007. 4445. 5086. 5945. 7389. 8671. 9502. 11149. 13757. 1151. 1151. 1151. 1602. 1894. 2113. 2346. 2696. 3147. 3905. 4591. 5028. 5902. 7273. 1777. 1777. 1777. 2069. 2302. 2638. 2827. 3424. 3730. 4342. 5042. 5480. 6353. 7621. 199. 199. 199. 199. 210. 210. 210. 218. 218. 224. 224. 224. 224. 224. 844. 844. 844. 844. 903. 903. 903. 931. 931. 961. 961. 961. 961. 961. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1136. 1180. 1180. 1180. 1238. 4-Pole Ampere Rating Elbow Stack Elbow Tee Cross Tap Box End Tap Box Center Flanged End Swbd. Conn. 225–1350 Al 225–1600 Cu 1' 2' 3' 4' 1' 4' 1' 4' 4' 4' 4' 1600–3200 Al 2000–4000 Cu 2' 3' 5' 6' 1' 4' 1' 4' 4' 4' 4' 4000 Al 5000 Cu 3' 4' 6' 8' 1' 4' 1' 4' 4' 4' 4' “M” Rating/Standard Rating Conversion Table 1000/A Square Inch “M” Rating Standard 55°C Rating 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 600 800 1200 1350 1600 2000 2000 Sentron 2500 4000 4000 4000 5000 Elbows other than 90° double the labor charge. connections to other manufactures switchboard, multiply accessory charge by 2.5 (Suffix is FO). Feeder only. 1600A “M” rating is a dedicated offering. Consult factory for pricing. XFMR Throat Expansion Section Reducer Fusible Reducer Unfused “L” Rating/Standard Rating Conversion Table 750/A Square Inch “L” Rating Standard 55°C Rating 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 600 800 1000 1200 1350 1600 2000 2000 2500 3000 4000 4000 Sentron Note: To price cross price 2 times elbow. For Discount Schedule BUSW Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-11 BUSWAY SYSTEMS To price complete device, add the following appropriate IP feeder footage to the accessory charge. 14 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 5000 Sentron Busway Systems ® Hangers, Floor Supports Trapeze Hangers Catalog Number Selection Structural Steel Hangers List Price $ Catalog Number List Price $ Wall Mounted Hangers Catalog Number List Price $ SXTH1 26.00 SXSS1 36.00 SXWH1 160.00 SXTH2 35.00 SXSS2 44.00 SXWH2 183.00 SXTH3 40.00 SXSS3 51.00 SXWH3 232.00 SXTH4 54.00 SXSS4 60.00 SXWH4 273.00 Single Drop Rod Hangers Aluminum BUSWAY SYSTEMS 14 Catalog Number Copper List Price $ Catalog Number List Price $ SXDRA1 46.00 SXDRC1 54.00 SXDRA2 54.00 SXDRC2 66.00 SXDRA3 60.00 SXDRC3 74.00 SXDRA4 66.00 SXDRC4 80.00 SXDRA5 74.00 SXDRC5 86.00 SXDRA6 80.00 SXDRC6 92.00 SXDRA7 86.00 SXDRC7 104.00 Spring Hanger / Floor Support Catalog Number List Price $ SXSH4 235.00 SXSH6 243.00 SXSH8 255.00 SXSH10 264.00 SXSH12 273.00 SXSH14 282.00 Lifting Kit Catalog Number SXLK List Price $ 63.00 Sway Brace Bracket Catalog Number SXSB List Price $ 91.00 Busway Assembly Tool Catalog Number SXBAT See List Price $ 63.00 pages 14-38 to 14-39 for Hanger Application information. 14-12 Used for mounting 400 and 600A Sentron Bus Plugs in riser applications. One kit required per bus plug. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW Sentron® Bus Plugs Catalog Numbering System Selection / Application Sentron Bus Plugs—Circuit Breaker (Installed) S L E C S 䊱 䊱 䊱 䊱 햲 3 2 0 1 5 0 G 䊱 䊱 䊱 䊱 䊱 햳 E D 2 䊱 Plug Type SL = Sentron II Circuit Breaker Frame E= F= J= L= M= 15–125A 70–250A 200–400A 250–600A 500–800A Enclosure Type C = Circuit Breaker Enclosure L = Current Limiting Enclosure Cradle Designation S = 3Ø3W, 3Ø4W>400A 200%N>200A only 14 Configuration 3 = 3Ø, 3W 4 = 3Ø, 4W 5 = 3Ø, 4W 200% neutral햴햵 BUSWAY SYSTEMS Breaker Voltage 2 = 240V 햶 4 = 480V 햷 6 = 600V Ampere Trip Rating IP Rating 0 = IP40 4 = IP55 Ground Designation G = Internal Ground IG = Isolated Ground Circuit Breaker Frame Identification Sentron SLVB Bus Plugs—Fusible S L V B R 3 2 1 0 G 䊱 䊱 䊱 䊱 䊱 䊱 䊱 䊱 Plug Type SL = Sentron II Heavy Duty Fusible Switch VB Orientation R = Riser H = Horizontal Configuration (Poles/Wires) 3 = 3Ø3W 4 = 3Ø4W 5 = 3Ø4W 200% Neutral Voltage 2 = 240V 6 = 600V Max Ampere Rating 1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600A IP Rating 0 = IP40 4 = IP55 Ground Designation G = Internal Ground IG = Isolated Ground 햲 The S digit is only used on 3- and 4-wire (100%N) plugs that are greater than 400A and 200%N plugs greater than 200A. Lower amperage plugs do not require this digit. (Ex. SLID3610, SLEC32060ED2) 햳 The G and IG digits are used to specify internal and isolated ground respectively. Integral (housing) ground plugs do not require this digit. (Ex. SLID3610, SLEC360150ED6) 햴 Available through 400A only. 햵 Available with E, F and J Frame breakers only. 햶 Available with ED2 breakers only. 햷 Available with ED4 and HHED6 breakers only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-13 Sentron® SLVB Bus Plugs Bus Plugs / Fusible Plugs Ampere Rating 3-Pole, 250 30A 60A 100A 200A 400A햳햴 BUSWAY SYSTEMS 14 600A햳햴 Ampere Rating 3-Pole, 600 30A 60A 100A 200A 400A햳햴 600A햳햴 Catalog Number Volt 햲 List Price $ Ampere Rating 4-Pole, 250 734.00 833.00 877.00 807.00 907.00 950.00 1206.00 1307.00 1349.00 2017.00 2116.00 2160.00 5191.00 5291.00 5377.00 8064.00 8164.00 8251.00 SLVB*3210 SLVB*3210G SLVB*3210IG SLVB*3220 SLVB*3220G SLVB*3220IG SLVB*3230 SLVB*3230G SLVB*3230IG SLVB*3240 SLVB*3240G SLVB*3240IG SLVB*3250 SLVB*3250G SLVB*3250IG SLVB*3260 SLVB*3260G SLVB*3260IG Catalog Number Volt 햲 Selection List Price $ SLVB*3610 SLVB*3610G SLVB*3610IG SLVB*3620 SLVB*3620G SLVB*3620IG SLVB*3630 SLVB*3630G SLVB*3630IG SLVB*3640 SLVB*3640G SLVB*3640IG SLVB*3650 SLVB*3650G SLVB*3650IG SLVB*3660 SLVB*3660G SLVB*3660IG 30A 100A 200A 400A햳햴 600A햳햴 Ampere Rating List Price $ Catalog Number Volt,햲 30A 100A 200A 400A햳햴 600A햳햴 872.00 970.00 1014.00 893.00 992.00 1035.00 1409.00 439.00 1476.00 2316.00 2414.00 1684.00 5833.00 5933.00 6032.00 8229.00 8328.00 8427.00 List Price $ SLVB*5210 SLVB*5210G SLVB*5210IG SLVB*5220 SLVB*5220G SLVB*5220IG SLVB*5230 SLVB*5230G SLVB*5230IG SLVB*5240 SLVB*5240G SLVB*5240IG SLVB*5250 SLVB*5250G SLVB*5250IG — — — 1010.00 1109.00 1191.00 1084.00 1183.00 1265.00 845.00 1578.00 676.00 2613.00 1841.00 2348.00 6241.00 6500.00 7152.00 — — — Catalog Number List Price $ List Price $ 200% Neutral햲 SLVB*4610 SLVB*4610G SLVB*4610IG SLVB*4620 SLVB*4620G SLVB*4620IG SLVB*4630 SLVB*4630G SLVB*4630IG SLVB*4640 SLVB*4640G SLVB*4640IG SLVB*4650 SLVB*4650G SLVB*4650IG SLVB*4660 SLVB*4660G SLVB*4660IG 60A Catalog Number 200% Neutral햲 SLVB*4210 SLVB*4210G SLVB*4210IG SLVB*4220 SLVB*4220G SLVB*4220IG SLVB*4230 SLVB*4230G SLVB*4230IG SLVB*4240 SLVB*4240G SLVB*4240IG SLVB*4250 SLVB*4250G SLVB*4250IG SLVB*4260 SLVB*4260G SLVB*4260IG 60A 4-Pole, 600 807.00 907.00 950.00 870.00 969.00 1013.00 1227.00 1328.00 1371.00 2139.00 2239.00 2283.00 5537.00 5637.00 5725.00 8005.00 8106.00 8205.00 Catalog Number Volt,햲 906.00 1005.00 1049.00 937.00 1036.00 1080.00 1376.00 1476.00 1519.00 2451.00 2476.00 2519.00 5977.00 6076.00 6176.00 8838.00 8937.00 9036.00 SLVB*5610 SLVB*5610G SLVB*5610IG SLVB*5620 SLVB*5620G SLVB*5620IG SLVB*5630 SLVB*5630G SLVB*5630IG SLVB*5640 SLVB*5640G SLVB*5640IG SLVB*5650 SLVB*5650G SLVB*5650IG — — — 1045.00 1142.00 1187.00 1074.00 1175.00 1219.00 1591.00 1601.00 1645.00 2642.00 2773.00 2817.00 7327.00 8427.00 9269.00 — — — Note: Replace * in catalog number with “H” for horizontal applications and “R” for riser applications. Ground Detector And Potentializer Plug Description For 2 or 3-pole 240 and 480 volt service. (IP40 construction only) Fuse Adapter Kits Catalog Number List Price $ SLPGR3140G 819.00 Description Catalog Number Spring Kit SXSK List Price $ 32.00 plugs shown are rated IP40; if IP55 rating is desired, substitute a “4” for “0” in position 8 (or 9 for cradle plugs) of catalog number and apply one of the following list price adders: 30A, 60A: $229. 100A: $307. 200A: $579. 400A, 600A: $1039. 햳 400A and larger bus plugs that require auxilary support. See also SXSK Spring Kit. 14-14 Std Fuse Class Class R Catalog Number List Price $ Class T Catalog Number List Price $ Class J Catalog Number List Price $ 250V Note: Available in IP40 construction only. 햲 All Switch Rating 30A 60A 100A 200A 400A햳햴 600A햳햴 H, H, H, H, H, H, K K K K K, J K, J SLR2030 SLR2060 SLR2100 SLR2200 SLR2400 SLR2600 105.00 132.00 89.00 89.00 132.00 132.00 — — SLT2100 SLT2200 SLT2400 SLT2600 — — 92.00 124.00 124.00 141.00 — — — — — SLJ2600 — — — — — 529.00 H, H, H, H, H, H, K, K, K, K, K, K, SLR6030 SLR6060 SLR6100 SLR6200 SLR6400 SLR6600 124.00 124.00 89.00 89.00 132.00 132.00 — — SLT6100 SLT6200 SLT6400 SLT6600 — — 141.00 172.00 185.00 210.00 — — — — — SLJ6600 — — — — — 249.00 600V 30A 60A 100A 200A 400A햳햴 600A햳햴 J J J J J J 햴 Used on 400A and larger bus plugs that require auxilary support and that are mounted on vertical/riser busway. Kit contains two springs (part number 32-9909-04). One kit required per bus plug. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BPLU Sentron® Bus Plugs Bus Plugs with Standard Circuit Breakers Ampere Rating Catalog Number List Price $ E Frame 3-Pole, 240 Volt, ED2 Breaker 15-60A 70-100A SLEC32***0ED2 SLEC32***0GED2 SLEC32***0IGED2 SLEC32***0ED2 SLEC32***0GED2 SLEC32***0IGED2 1106.00 1210.00 1255.00 1106.00 1210.00 1255.00 E Frame 3-Pole, 480 Volt, ED4 Breaker 15-60A 70-100A 110-125A SLEC34***0ED4 SLEC34***0GED4 SLEC34***0IGED4 SLEC34***0ED4 SLEC34***0GED4 SLEC34***0IGED4 SLEC34***0ED4 SLEC34***0GED4 SLEC34***0IGED4 1363.00 1468.00 1512.00 1512.00 1617.00 1662.00 1710.00 1817.00 1662.00 E Frame 3-Pole, 600 Volt, ED6 Breaker 110-125A F Frame 3-Pole, 600 Volt, FXD6 Breaker 70-225A 250A SLFC36***0FXD6 SLFC36***0GFXD6 SLFC36***0IGFXD6 SLFC362500FXD6 SLFC362500GFXD6 SLFC362500IGFXD6 3733.00 3838.00 3883.00 4453.00 4557.00 4603.00 J Frame 3-Pole, 600 Volt, JXD6 Breaker 200-400A SLJC36***0JXD6 SLJC36***0GJXD6 SLJC36***0IGJXD6 7301.00 7405.00 7451.00 List Price $ Ampere Rating Catalog Number E Frame 4-Pole, 240 Volt, ED2 Breaker 15-60A 70-100A SLEC42***0ED2 SLEC42***0GED2 SLEC42***0IGED2 SLEC42***0ED2 SLEC42***0GED2 SLEC42***0IGED2 1262.00 1367.00 1411.00 1262.00 1367.00 1411.00 E Frame 200% Neutral SLEC52***0ED2 SLEC52***0GED2 SLEC52***0IGED2 SLEC52***0ED2 SLEC52***0GED2 SLEC52***0IGED2 15-60A 70-100A E Frame 4-Pole, 480 Volt, ED4 Breaker 15-60A 70-100A 110-125A SLEC44***0ED4 SLEC44***0GED4 SLEC44***0IGED4 SLEC44***0ED4 SLEC44***0GED4 SLEC44***0IGED4 SLEC44***0ED4 SLEC44***0GED4 SLEC44***0IGED4 1520.00 1624.00 1670.00 1670.00 1773.00 1819.00 1869.00 1973.00 2018.00 15-60A 70-100A 110-125A 1661.00 1765.00 1809.00 1825.00 1930.00 1975.00 2027.00 2132.00 2178.00 SLEC54***0ED4 SLEC54***0GED4 SLEC54***0IGED4 SLEC54***0ED4 SLEC54***0GED4 SLEC54***0IGED4 SLEC54***0ED4 SLEC54***0GED4 SLEC54***0IGED4 15-60A 70-100A 110-125A 70-225A 250A 3855.00 3946.00 3992.00 4538.00 4665.00 4901.00 15-60A 70-100A 110-125A 200-400A 7940.00 8089.00 8089.00 70-200A 225-250A 450-600A SLLCS36***0LXD6 SLLCS36***0GLXD6 SLLCS36***0IGLXD6 10457.00 10707.00 10838.00 2083.00 2187.00 2233.00 2253.00 2360.00 2407.00 2393.00 2498.00 2543.00 SLFC56***0FXD6 SLFC56***0GFXD6 SLFC56***0IGFXD6 SLFC56***0FXD6 SLFC56***0GFXD6 SLFC56***0IGFXD6 4177.00 4281.00 4326.00 4177.00 4281.00 4326.00 J Frame 200% Neutral 200A 225-400A L Frame 3-Pole, 600 Volt, LXD6 Breaker SLEC56***0ED6 SLEC56***0GED6 SLEC56***0IGED6 SLEC56***0ED6 SLEC56***0GED6 SLEC56***0IGED6 SLEC56***0ED6 SLEC56***0GED6 SLEC56***0IGED6 F Frame 200% Neutral J Frame 4-Pole, 600 Volt, JXD6 Breaker SLJC46***0JXD6 SLJC46***0GJXD6 SLJC46***0IGJXD6 1927.00 2032.00 2078.00 2101.00 2203.00 2249.00 2229.00 2339.00 2386.00 E Frame 200% Neutral F Frame 4-Pole, 600 Volt, FXD6 Breaker SLFC46***0FXD6 SLFC46***0GFXD6 SLFC46***0IGFXD6 SLFC462500FXD6 SLFC462500GFXD6 SLFC462500IGFXD6 1630.00 1734.00 1778.00 1630.00 1734.00 1778.00 E Frame 200% Neutral E Frame 4-Pole, 600 Volt, ED6 Breaker SLEC46***0ED6 SLEC46***0GED6 SLEC46***0IGED6 SLEC46***0ED6 SLEC46***0GED6 SLEC46***0IGED6 SLEC46***0ED6 SLEC46***0GED6 SLEC46***0IGED6 List Price $ SLJC562000JXD6 SLJC562000GJXD6 SLJC562000IGJXD6 SLJCS56***0JXD6 SLJCS56***0GJXD6 SLJCS56***0IGJXD6 8275.00 8379.00 8425.00 8833.00 8939.00 8984.00 L Frame 4-Pole, 600 Volt, LXD6 Breaker SLLCS46***0LXD6 450-600A SLLCS46***0GLXD6 SLLCS46***0IGLXD6 10999.00 11251.00 11382.00 Description Catalog Number List Price $ Spring Kit SXSK 32.00 M Frame 3-Pole, 600 Volt, MXD6 Breaker M Frame 4-Pole, 600 Volt, MXD6 Breaker 500-800A SLMCS36***0MXD6 12246.00 SLMCS36***0GMXD6 12617.00 SLMCS36***0IGMXD6 12681.00 Replace “***” with breaker trip rating. Example: SLEC36060ED6, for 60A trip. plugs shown have an IP40 rating, if IP54/55 is desired substitute ”4” for ”0” in position 10 (or 11 for cradle plugs) and add the following charge: E Frame: $149. Ex. SLEC360604ED6 F Frame: $353. Ex. SLFC360704FXD6 J Frame: $913. Ex. SLJC36100JXD6 L Frame: $960. Ex. SLLCS365004LXD6 M Frame: $1046. Ex. SLMCS368004MXD6 All Discount Schedule BPLU SLMCS46***0MXD6 500-800A SLMCS46***0GMXD6 SLMCS46***0IGMXD6 For 12972.00 13343.00 13405.00 the following breaker charges, change the catalog number suffix and add the appropriate charge: 15-60A: HHED6 $624. Ex. SLEC36***0HHED6 70-100A: HHED6 $561. Ex. SLEC36***0HHED6 110-125A: HHED6 $761. Ex. SLEC36***0HHED6 F Frame: FD6 $446. Ex. SLFC36***0FD6 F Frame: HFD6 $2777. Ex. SLFC36***0HFD6 J Frame: JD6 $189. Ex. SLJC36***0JD6 J Frame: HJD6 $2772. Ex. SLJC36***0HJD6 L Frame: LD6 $189. Ex. SLLCS36***0LD6 L Frame: HLD6 $2247. Ex. SLLCS36***0HLD6 M Frame: MD6 $588. Ex. SLMCS36***0MD6 M Frame: HMD6 $2247. Ex. SLMCS36***0HMD6 400A and larger bus plugs that require auxilary support. See also SXSK Spring Kit. on 400A and larger bus plugs that require auxilary support and that are mounted on vertical/riser busway. Kit contains two springs (part number 32-9909-04). One kit required per bus plug. Used Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-15 BUSWAY SYSTEMS 70-100A 1503.00 1608.00 1653.00 1668.00 1772.00 1818.00 1870.00 1974.00 2019.00 Catalog Number 14 15-60A SLEC36***0ED6 SLEC36***0GED6 SLEC36***0IGED6 SLEC36***0ED6 SLEC36***0GED6 SLEC36***0IGED6 SLEC36***0ED6 SLEC36***0GED6 SLEC36***0IGED6 Ampere Rating Selection Sentron® Bus Plugs Bus Plugs with Current Limiting Circuit Breakers 햲햳 Ampere Rating Catalog Number List Price $ E Frame 3-Pole, 600 Volt, CED6 Breaker 15-60A 70-100A 110-125A SLEL36***0CED6 SLEL36***0GCED6 SLEL36***0IGCED6 SLEL36***0CED6 SLEL36***0GCED6 SLEL36***0IGCED6 SLEL36***0CED6 SLEL36***0GCED6 SLEL36***0IGCED6 4664.00 4769.00 4813.00 4664.00 4769.00 4813.00 4664.00 4769.00 4813.00 F Frame 3-Pole, 600 Volt, CFD6 Breaker 100-225A 8399.00 8504.00 8550.00 8407.00 8512.00 8557.00 J Frame 3-Pole, 600 Volt, CJD6 Breaker 200-400A햴 BUSWAY SYSTEMS 14 250A SLFL36***0CFD6 SLFL36***0GCFD6 SLFL36***0IGCFD6 SLFL362500CFD6 SLFL362500CGFD6 SLFL362500ICGFD6 SLJL36***0CJD6 SLJL36***0CGJD6 SLJL36***0ICGJD6 12708.00 12812.00 12858.00 Ampere Rating Catalog Number Selection List Price $ Ampere Rating E Frame 4-Pole, 600 Volt, CED6 Breaker 15-60A 70-100A 110-125A SLEL46***0CED6 SLEL46***0GCED6 SLEL46***0IGCED6 SLEL46***0CED6 SLEL46***0GCED6 SLEL46***0IGCED6 SLEL46***0CED6 SLEL46***0GCED6 SLEL46***0IGCED6 4821.00 4926.00 4971.00 4821.00 4926.00 4971.00 4821.00 4926.00 4971.00 100-225A 250A 8508.00 8613.00 8658.00 8843.00 8948.00 8993.00 15-60A 70-100A 110-125A 200-400A햴 13347.00 13452.00 13498.00 70-200A 225-250A 450-600A햴 햲 SLLLS36***0CLD6 SLLLS36***0GCLD6 SLLLS36***0IGCLD6 16688.00 16940.00 17070.00 Replace “***” with breaker trip rating. Example: SLEC36060ED6, for 60A trip. 햳 All plugs shown have an IP40 rating, if IP54/55 is desired, substitute ”4” for ”0” in position 10 (or 11 for cradle plugs) and add the following charge: E Frame: $149. Ex. SLEC360604ED6 F Frame: $353. Ex. SLFC360704FXD6 J Frame: $913. Ex. SLJC361004JXD6 L Frame: $960. Ex. SLLCS365004LXD6 M Frame:$1046. Ex. SLMCS368004MXD6 14-16 5373.00 5478.00 5522.00 5373.00 5478.00 5522.00 5373.00 5478.00 5522.00 SLFL56***0CFD6 SLFL56***0GCFD6 SLFL56***0IGCFD6 SLFL56***0CFD6 SLFL56***0GCFD6 SLFL56***0IGCFD6 8843.00 8948.00 8993.00 8843.00 8948.00 8993.00 J Frame 200% Neutral 200A햴 225-400A햴 L Frame 3-Pole, 600 Volt, CLD6 Breaker SLEL56***0CED6 SLEL56***0GCED6 SLEL56***0IGCED6 SLEL56***0CED6 SLEL56***0GCED6 SLEL56***0IGCED6 SLEL56***0CED6 SLEL56***0GCED6 SLEL56***0IGCED6 F Frame 200% Neutral J Frame 4-Pole, 600 Volt, CJD6 Breaker SLJL46***0CJD6 SLJL46***0GCJD6 SLJL46***0IGCJD6 List Price $ E Frame 200% Neutral F Frame 4-Pole, 600 Volt, CFD6 Breaker SLFL46***0CFD6 SLFL46***0GCFD6 SLFL46***0IGCFD6 SLFL462500CFD6 SLFL462500GCFD6 SLFL462500IGCFD6 Catalog Number SLJL562000CJD6 SLJL562000GCJD6 SLJL562000IGCJD6 SLJLS56***0CJD6 SLJLS56***0GCJD6 SLJLS56***0IGCJD6 13786.00 13832.00 13681.00 14241.00 14346.00 14392.00 L Frame 4-Pole, 600 Volt, CLD6 Breaker 450-600A햴 SLLLS46***0CLD6 SLLLS46***0GCLD6 SLLLS46***0IGCLD6 17232.00 17483.00 17613.00 햴 400A and larger bus plugs that require auxilary support. See also SXSK Spring Kit. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BPLU Sentron Busway Systems ® Fusible Cubicles, Molded Case Circuit Breaker Cubicles Fusible Cubicles Selection Solid State Molded Case Circuit Breaker Cubicles List Price $ List Price $ Ampere Rating 200 400 600 800 1200 3-Pole, 600V 4-Pole, 480/277V IP40 IP40 7800. 8514. 10942. 16546. 20152. 7925. 10139. 13066. 17957. 22508. Molded Case Circuit Breaker Cubicles List Price $ Ampere Rating 3-Pole, 600V 4-Pole, 480/277V IP40 IP40 JD6 LD6 MD6 ND6 PD6 RD6 200–400 300–600 600–800 800–1200 1400–1600 1800–2000 10708. 16849. 22828. 28844. 33682. 38269. 11138. 17385. 24043. 29540. 34147. 38841. Breaker Frame Size Maximum Ampere Rating AC Interrupting Capacity Symmetrical (RMS) Amperes List Price $ With Breaker 240 Volt 3-Pole 480 Volt 600 Volt RL-800 RL-1600 RL-2000 RL-3200 RL-4000 30,000 50,000 65,000 65,000 85,000 30,000 50,000 65,000 65,000 85,000 30,000 50,000 65,000 65,000 85,000 25828. 37361. 54090. 114720. 166200. 43495. 76130. 83086. 174007. 261011. Type RL (Fused) RLF-800 RLF-3200 RLF-4000 800 3200 4000 200,000 200,000 200,000 200,000 200,000 200,000 200,000 200,000 200,000 40149. 68564. 166516. 42165. 70388. 170280. 9093. 12709. 11251. 15201. 200–400 8745. 12329. 10873. 14836. SLD6 SLD6G SLD6NT SLD6NGT 300–600 13758. 17125. 15784. 19850. 14195. 17562. 16192. 20302. SMD6A SMD6AG SMD6ANT SMD6ANGT 600–800 19530. 21788. 19922. 21628. 20491. 22707. 20928. 22780. SND6A SND6AG SND6ANT SND6ANGT 800–1200 25243. 26263. 26059. 29993. 25796. 28085. 26627. 30548. SPD6 SPD6G SPD6NT SPD6NGT 1400–1600 27502. 27590. 29484. 30840. 27880. 27982. 24281. 31232. Bolted Pressure Switches List Price $ Ampere Rating 800 1600 2000 3200 4000 IP40 SJD6 SJD6G SJD6NT SJD6NGT 3-Phase, 4-Wire Type RL 4-Pole, 480/277V IP40 BUSWAY SYSTEMS Power Circuit Breaker Ampere Rating 14 Breaker Frame Breaker Frame 3-Pole, 600V 480 Volt 600 Volt 3-Pole 4-Pole 3-Pole 4-Pole 800 18245. 24396. 25156. 25625. 1200 27475. 28135. 28832. 29529. 1600 30048. 30974. 31594. 32495. 2000 36778. 37856. 38616. 39769. 2500 43596. 45041. 45763. 47297. 3000 56168. 57867. 58982. 60832. 4000 79120. 81933. 83075. 86040. Fuses not included. IP55 rating add 12% to list price. For electrically operated, specify control voltage. For Discount Schedule BUSW Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-17 Sentron Busway Systems ® Meter Centers Selection Molded Case Circuit Breaker Cubicles with Meter Tap Stack Provisions Meter Center Tap Stacks—IP40 List Price $ Busway L Frame Breaker N Frame Breaker Aluminum Busway 600A - 1200A 8503. 13030. 1350A - 1600A 10150. 14677. 2000A - 3000A 12346. 16871. Copper Busway 9875. 14402. 2000A 11796. 16323. 2500A - 4000A 15912. 20439. 5000A 18655. 23182. 3-Pole Isolated Ground 4-Pole 4-Pole Internal Ground 4-Pole Isolated Ground 100 1005. 1122. 1194. 1355. 1456. 1618. 200 400 600 800 1000 1200 1063. 1106. 1165. 1210. 1268. 1311. 1180. 1223. 1281. 1339. 1398. 1456. 1268. 1326. 1385. 1443. 1501. 1560. 1428. 1501. 1560. 1631. 1705. 1763. 1530. 1602. 1675. 1748. 1821. 1894. 1689. 1777. 1850. 1861. 2011. 2097. Note: Prices do not include meter centers. BUSWAY SYSTEMS 14 800A - 1600A Amps List Price $ 3-Pole Internal 3-Pole Ground For For IP55 rating add 12% to list price. IP55 add 28% add to list price. 14-18 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW Busway Systems National Electric Code feeder or branch circuits from the busway shall contain the over current devices required for the protection of the feeder or branch circuits. The plug0in device shall consist of an externally operable circuit breaker or an externally operable fusible switch. Where such devices are mounted out of reach and contain disconnecting means, suitable means such as ropes, chains or sticks shall be provided for operating the disconnecting means from the floor. Exception No.1: As permitted in 240.21. Exception No. 2: For fixed or semi fixed luminaries (light fixtures), where the branch circuit over current device is part of the luminaries (fixture) cord plug on cord-connected luminaries (fixtures). Exception No.3: Where luminaries (fixtures) without cords are plugged in directly into busway and the over current device is mounted on the luminaries (fixture). (D) Rating of Over Current Protection – Branch Circuits. A busway used as a branch circuit shall be protected against over current in accordance with 210.20. 368.30 Support. Busways shall be securely supported at intervals not exceeding 1.5 m (5 ft) unless otherwise designed and marked. 368.50 Branches from Busways. Branches from busways shall be permitted to be made in accordance with 368.56(A), (B) and (C). (A)General. Branches from busways shall be permitted to use any of the following wiring methods: (1) Type AC Armored Cable (2) Type MC metal-clad Cable (3) Type MI mineral-insulated, metal sheathed cable (4) Type IMC intermediate metal conduit (5) Type RMC rigid metal conduit (6) Type FMC flexible metal conduit (7) Type LFMC liquid tight flexible metal conduit (8) Type RNC rigid nonmetallic conduit (9) Type LFNC liquid tight flexible nonmetal conduit (10 Type EMT electrical metallic tubing (11) Type ENT electrical nonmetallic tubing (12) Busways (13) Strut-type channel raceway (14) Surface Metal raceways (15) Surface nonmetallic raceways Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-19 BUSWAY SYSTEMS riser busway to prevent liquids from entering the opening. Electrical equipment shall be located so that it will not be damaged by liquids that are retained by the curb. FPN: See 300.21 for information concerning the spread of fire or products of combustion. 368.12 Uses Not Permitted. (A) Physical Damage. Busways shall not be installed where subject to severe physical damage or corrosive vapors. (B) Hoist ways. Busways shall not b installed in Hoist ways. (C) Hazardous Locations. Busways shall not be installed in any hazardous (Classified) location, unless specifically approved for such use. FPN: See 501.10(B) (D) Wet Locations. Busway shall not be installed outdoors or in wet damp locations unless identified for such use. (E) Working Platform. Lighting busway and trolley busway shall not be installed less than 2.5 m (8 ft) above the floor or working platform unless provided with a cover identified for the purpose. 368.17 Over current Protection. Over current protection shall be provided in accordance with 368.17(A) through (D). (A) Rating of over current protection – Feeders. A busway shall be protected against over current in accordance with the allowable current rating of the busway. Exception No. 1: The applicable provisions of 240.4 shall be permitted. Exception No. 2: Where used as transformer secondary ties, the provisions of 450.6(A)(3) shall be permitted. (B) Reduction in Ampacity Size of Busway. Over current protection shall be required where busways are reduced in ampacity. Exception: For industrial establishments only, omission of over current protection shall be permitted at points where busway are reduced in ampacity, provided that the length of the busway having the smaller ampacity does not exceed 15m(50ft) and has ampacity at least equal to one-third the rating or setting of the over current device next back on the line, and provided that such busway is free from contact with combustible material. (C) Feeder or Branch Circuits. Where a busway is used as a feeder, devices or plug-in connections for tapping off 14 I.General Requirements 368.1 Scope. This article covers serviceentrance, feeder and branch-circuit busways and associated fittings. 368.2 Definition. Busway. A grounded metal enclosure containing factory-mounted, bare or insulated conductors, which are usually copper or aluminum bars, rods or tubes. FPN: For cables, refer to article 370. II. Installation 368.10 Uses Permitted. Busways shall be permitted to be installed where they are located in accordance with 368.10(A) through (C). (A) Exposed. Busways shall be permitted to be located in the open where visible, except as permitted in 368.10 (C). (B) Concealed. Busways shall be permitted to be installed behind access panels, provided the busways are totally enclosed, of non-ventilating-type construction and installed so that the joints between sections and at fittings are accessible for maintenance purposes. Where installed behind access panels, means of access shall be provided and either of the following conditions shall be met: (1) The space behind the access panels shall not be used for air-handling purposes. (2) Where the space behind the access panels is used for environmental air, other than ducts and plenums, there shall be no provisions for plug-in connections and the conductors shall be insulated. (C) Through walls and Floors. Busways shall be permitted to be installed through walls and floors in accordance with (C)(1) and (C)(2). (1) Walls. Unbroken lengths of busway shall be permitted to be extended through dry walls. (2) Floors. Floor penetrations shall comply with (a) and (b). (a) Busways shall be permitted to be extended vertically through dry floors if totally enclosed (unventilated) where passing through and for a minimum distance of 1.8m (6ft) above the floor to provide adequate protection from physical damage. (b) In other than industrial establishments, where a vertical riser penetrates two or more dry floors, a minimum 100mm (4 in) high curb shall be installed around all floor openings for Technical Busway Systems BUSWAY SYSTEMS 14 National Electric Code Where a separate equipment grounding conductor is used, connection of the equipment grounding conductor to the busway shall comply with 250.8 and 250.12. (B) Cord and Cable Assemblies. Suitable cord and cable assemblies approved for extra-hard usage and hard usage, and listed bus drop cable shall be permitted as branches from the busway for the connection of portable equipment or the connection of stationary equipment to facilitate their interchange in accordance with 400.7 and 400.8 and the following conditions: (1) The cord or cable shall be attached to the building by the approved means. (2) The length of the cord or cable form a busway plug-in device to a suitable tension take-up support device shall not exceed 1.8 m (6 ft.). (3) The cord and cable shall not be installed as a vertical riser from the tension take-up support device to the equipment served. (4) Strain relief cable grips shall be provided for the cord or cable at the busway plug-in device and equipment terminations. Exception to (B)(2): In industrial establishments only, where the conditions of maintenance and supervision ensure that only qualified persons service the installation, lengths exceeding 1.8 m (6 ft.) shall be permitted between the busway plug-in device and the tension take-up support device where the cord or cable is supported at intervals not exceeding 2.5 m (8 ft.). (C) Branches from Trolley-Type Busways. Suitable cord and cable assemblies approved for extra-hard sage or hard-usage and listed bus drop cable shall be permitted as branches from trolley-type busways for the connection of moveable equipment in accordance with 400.7 and 400.8. 368.58 Dead Ends. A dead end of a busway shall be closed. 368.60 Grounding. Busway shall be grounded. III. Construction 368.120 Marking. Busway shall be marked with the voltage and current rating for which they are designed and with the manufacturers name or trademark in such a manner as to be visible after installation. 14-20 Technical IV. Requirements for over 600 Volts, Nominal 368.214 Adjacent and Supporting Structures. Metal enclosed busways shall be installed so that temperature rise from induced circulating currents in any adjacent metallic parts will not be hazardous to personnel or constitute a fire hazard. 368.234 Barriers and Seals. (A) Vapor Seals. Busway runs that have sections located inside and outside of a building shall have a vapor seal at the building wall to prevent interchange of air between indoor and outdoor sections. Exception: Vapor seals shall not be required in forced-cooled bus. (B) Fire Barriers. Fire barriers shall be provided where fire walls, floors and ceilings are penetrated. FPN: See 300.21 for information concerning the spread of fire or products of combustion. 368.236 Drain Facilities. Drain plugs, filter drains or similar methods shall be provided to remove condensed moisture from low points on a busway run. 368.237 Ventilated Bus Enclosures. Ventilated busway enclosures shall be installed in accordance with Article 110, Part III and 490.24. 368.238 Terminations and Connections. Where bus enclosures terminate at machines cooled by flammable gas, seal-off bushings, baffles or other means shall be provided to prevent accumulation of flammable gas in the busway enclosures. All conductor termination and connection hardware shall be accessible for installation, connection and maintenance. 368.239 Switches. Switching devices or disconnecting links provided in the busway run shall have the same momentary rating as the busway. Disconnecting links shall be plainly marked to be removable only when the bus is de-energized. Switching devices that are not load-break shall be interlocked to prevent operation under load and disconnecting link enclosures shall be interlocked to prevent access to energized parts. 368.240 Wiring 600 Volts or Less, Nominal. Secondary control devices and wiring that are provided as part of the metal-enclosed bus run shall be insulated by fire-retardant barriers from all primary circuit elements with the Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog exception of short lengths of wire, such as at instrument transformer terminals. 368.244 Expansion Fittings. Flexible or expansion connections shall be provided in long, straight runs of bus to allow for temperature expansion or contraction or where the busway run crosses the building vibration insulation joints. 368.258 Neutral. Neutral bus, where required shall be sized to carry all neutral load current, including harmonic currents and shall have adequate momentary and short circuit rating consistent with system requirements. 368.260 Grounding. Metal-enclosed busway shall be grounded. 368.320 Marking. Each busway run shall be provided with a permanent nameplate on which the following information shall be provided: (1) Rated voltage. (2) Rated continuous current; if bus is forced-cooled, both the normal forcedcooled rating and the self-cooled (not forced-cooled) rating for the same temperature rise shall be given. (3) Rated frequency. (4) Rated impulse withstand voltage. (5) Rated 60Hz withstand voltage (dry). (6) Rated momentary current. (7) Manufacturers name or trademark. FPN: See ANSI C37.23-1987(R1991), Guide for Metal enclosed Bus and Calculating Losses in Isolated-Phase Bus, for construction and testing requirements for metal enclosed bus. Busway Systems Sentron Busway Overview Sentron Busway for Global Power Distribution Applications Plating All bus bars are electroplated with tin. This unique tin plating provides excellent conductivity and resists outside elements from attaching to the bars. Optional silver plating is also available. Insulation Sentron Busway is insulated with an Epoxy Powder Coating system designed by Siemens Engineers, Epoxy System Engineers and Epoxy Powder Specialists, specifically for Siemens Busway products. The Siemens exclusive Electrostatic Spray insulation process produces uniform application of Epoxy powder over the entire conductor bar. This is further enhanced by the inline filter process and magnetic separator that helps to eliminate contaminants common to fluidized bed systems. The electrostatic application also provides a better coating consistency than that of the older fluidized bed process. The combination of electrostatic spray and lower oven temperatures produces a consistent coverage with fewer impurities and pinholes in the insulation. The lower oven temperatures reduce the risk of bar annealing, which affects the overall quality of the system. Sentron Busway insulation is Class B, 130°C Rated. Every bus bar and completed assembly is dielectricly tested to ensure the insulation is free of defects. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-21 BUSWAY SYSTEMS Housing Sentron Busway incorporates an all aluminum housing. This lightweight totally enclosed, non-ventilated housing resists rust and other elements, distributes heat away from the conductors, and provides an excellent ground path. The totally enclosed design also eliminates the need for derating of the system regardless of installation orientation. The housing is covered with an electrostatically applied light gray ANSI 61 polyester urethane powder paint that is scratch resistant and has a 1,000-hour salt spray resistance rating. Conductors Sentron Busway conductors have a compact construction and can be configured as 3-phase 3-wire, 3-phase 4-wire or 3-phase 4-wire with 200% neutral. The conductors may be ordered in copper (98% conductivity), 1000A/in2 M-Rated Copper, Aluminum (58% conductivity) and 750A/in2 L-Rated Aluminum. The optional 200% neutral helps to handle harmonic conditions that may exist. This system is especially useful with discharge lighting (fluorescent) and computer installations. This will help to minimize overheating and prolong the life cycle of your power distribution equipment. Ground Sentron Busway offers ground options to meet your specifications: standard integral aluminum housing ground and optional internal grounding bars. An optional isolated ground is also available which is especially useful in applications where a clean ground is needed. 14 Building on a solid foundation of advanced products for the construction industry, the Siemens Sentron name is recognized worldwide as synonymous with quality and consistent performance. Sentron Busway delivers impressive features and benefits that make it ideal for many types of industrial and construction implementations. Engineered to ensure the safe and efficient distribution of power in industrial, commercial and institutional environments world-wide, Sentron ampacities range from 225A to 5000A UL and IEC. Thanks to an innovative design, you benefit from labor-saving installation and a flexible, compact bus system that is an ideal fit for most applications. In fact, Sentron Busway is one of the industry's least laborintensive systems. Sentron Busway installs with minimal hardware and often costs less than cable and conduit installations. The lightweight aluminum housing acts as an integral ground, joint stacks connect with splice plates featuring a single-bolt design, and bus plugs and cable tap boxes offer the industry's largest wire bending space. An optional 200% neutral within the bus bar housing accommodates harmonics common in today's power systems. Sentron Busway conductors are insulated with a state-of-the-art epoxy insulation system, which is applied using an electrostatic spray process for optimal insulation integrity. Exemplifying the spirit of continuing innovation, Sentron Busway is now available with economical and convenient elbow stacks for changing left, right, up or down directions at 90 degrees. And, of course, Sentron Busway is certified to design standards worldwide, including UL, NEMA, IEC, CSA, VDE and BS. Siemens Busway Business uses industry leading technology in all its manufacturing processes. From bus bar fabrication to Electrostatic Spray Epoxy insulation, all the processes used in the manufacturing of Siemens Sentron Busway are electronically controlled to provide for consistent, high quality results, making Sentron Busway products best in its class. Overview Busway Systems BUSWAY SYSTEMS 14 Sentron Busway Overview Joint Stack Each Sentron Busway piece is shipped with a joint stack and joint covers installed at one end of the busway and a shipping end protector at the other end. The joint stacks feature a single bolt design and a special, torque indicating, double headed break-off bolt. This eliminates the need for torque wrenches and assures proper torque at installation of 55 ft.-lbs.(68 N-m). When the proper torque value is achieved, the top bolt head will shear off. Each joint stack allows for +/- .625 inches (15.8mm) adjustability at each joint. Over adjustment is prevented by the joint covers, which will only allow a .625 inch (15.8mm) adjustment when the knockouts on the joint cover are removed. It is possible to remove any joint connection assembly to allow electrical isolation or removal of a busway length without disturbing adjacent busway lengths. Isolation joint stacks are available and used to electrically isolate a busway section(s) within a busway run. For easy visual identification, isolation joint stack assemblies are painted white. Overview Plug-in Opening Sentron Busway offer plug-in style busway which feature plug-in openings rated for finger safety to IP2X in accordance with IEC 529 and BS EN 60439-1, -2 and BS EN 60529. Each plug-in opening has a reversible hinged dead front designed to protect the contact surfaces from dirt, dust or moisture. Gasketing is used where applications require a splash proof (IP55) rating. IP Ratings Sentron Busway is available in a variety of IP ratings. Use the chart below to determine the IP rating that best fits your application needs. Testing Each piece of Sentron Busway is factory tested before shipping. Tests performed include dielectric tests, which are used to insure integrity of insulation. In addition, Sentron Busway is tested in accordance with both UL and IEC standards. All Sentron Busway is manufactured and inspected in an ISO 9001:2000 registered facility. Standards All Sentron Busway products meet the following standards: UL 857 NEMA BU1 CSA C22.2 IEC 439-1(1993), IEC 439-2 (1993), IEC 529 (1989) BS EN 60529 BS EN 60439-1, 60439-2 UL 1479 DIN 4102 Parts 9&12 BS 6387 Parts 11.1 and 11.2 Labor Savings Using Sentron Busway instead of cable and conduit can create savings of up to 20 - 30% on total installed costs. Sentron busway is lightweight, compact and takes half the time to install as cable and conduit. Siemens Sentron Busway Cable/Conduit Conversion Software Program will show you side by side comparisons of busway vs. cable/conduit. These comparisons include material costs, labor costs, bill of materials, and technical information between busway and cable/conduit. Contact your local Siemens sales office to find out more information, or visit our web site at www.sea.siemens.com. Joint Assembly Plug-In Opening and Cover Levels of Protection Description Sentron Busway Code Description Feeder Plug-In Sentron Bus Plugs IP 2X Plug-In outlet protects against access to live parts by .472 in. (12 mm) test probe, even with cover opened. Finger Safe • • • IP 40 Enclosure protects against entry of .039 in. (1.0 mm) test probe. Indoor (Typical UL Designation) • • • IP 55 Enclosure protects against entry of dust and water jets. Splash Proof • • • IP 66 Enclosure is dust tight and protects against powerful water jets. Outdoor (International Only) • NEMA 3R Enclosure protects against rain, sleet and damage from ice formation. Outdoor - NAFTA • 14-22 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Busway Systems Sentron Bus Plug Overview Enclosure Ratings: ▪ IP40 ▪ IP55 Conductors: ▪ 3-phase, 3-wire ▪ 3-phase, 4-wire ▪ 3-phase, 4-wire 200% neutral (400A and below) Grounding: ▪ Integral (Housing) ▪ Internal ▪ Isolated BUSWAY SYSTEMS installation of the unit. Guide stabs prevent installing the bus plug 180 degrees out of rotation. In addition, the stabs provide vertical support for vertical applications. The bus plug ground stabs are designed to ensure positive contact with both the integral and optional internal busway grounds before the bus plug fingers contact the phase and neutral bars. Sentron Bus Plugs also feature bolt-on mounting to the busway housing for secure attachment. Sentron Bus Plugs can be configured for horizontal or vertical applications. The following Bus Plugs can be mounted (side by side) five (5) per busway side channel (Total 10 per 10' Section). ▪ 30-600 SLVBH Fusible (Horizontal) ▪ 30-200 SLVBR Fusible (Riser) ▪ 30-400 Circuit Breaker Sentron SLVB Fusible Bus Plugs feature a direct drive mechanism. The operating handle mounts directly to the switch mechanism for fewer moving parts. 14 SENTRON Bus Plugs are engineered with the installer and end user in mind. The installer will benefit from the numerous features, such as factory installed circuit breakers, compact footprint, generous wirebend space, and dual interlocks. The end user will appreciate the visible position indicator, as well as the spring loaded pad lockable latch which prevents access to unauthorized personel. SENTRON Bus Plugs are designed with an interlock device to prevent the door from being opened when the disconnect is on. This also prevents the disconnect from being turned on while the door is open. The interlock ensures that the protective device is “OFF” prior to installation or removal of the bus plug. Once the bus plug is properly installed, a spring - loaded, padlock latch provides additional security by preventing unauthorized access to the unit. Alignment and interlock stabs are features of the Sentron Bus Plugs engineered to prevent improper Overview Note: SLVBH Horizontal Application Shown. Contact Siemens for 200% Neutral Applications. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-23 Busway Systems Technical Data BUSWAY SYSTEMS 14 Technical R, X, Z and Ohms, Voltage Drop Ampere AL 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 Rating L-Rated 햴 — — — 400 600 800 1000 1200 1350,1600 2000 2500 2000 3000,3200 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated 햴 — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Bus Bar Width x 0.25 in. (6.4mm) Thick Ohms x 10.3 per 100 feet Line to Neutral R X Z (2) (2) (2) (2) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 2.38 (60.5) 3.25 (82.6) 4.38 (111.3) 5.38 (138.7) 6.50 (165.1) 8.75 (222.3) 5.63 (143.0) 6.75 (171.5) 7.50 (190.5) 9.00 (228.6) 3.94 4.08 4.26 3.42 2.45 1.86 1.39 1.21 0.91 0.68 0.54 0.48 0.62 1.13 1.23 1.32 1.06 0.74 0.59 0.24 0.48 0.35 0.29 0.28 0.33 0.21 4.10 4.26 4.46 3.58 2.56 1.95 1.41 1.29 0.98 0.74 0.61 0.58 0.51 0.88 1.66 2.64 2.82 2.50 2.32 1.50 2.19 2.11 2.09 2.24 2.53 2.34 1.02 1.91 3.03 3.24 2.88 2.66 1.81 2.48 2.38 2.34 2.47 2.73 2.61 1.15 2.15 3.40 3.64 3.24 2.99 2.10 2.75 2.64 2.57 2.67 2.91 2.85 1.27 2.38 3.75 4.02 3.57 3.29 2.39 3.00 2.87 2.78 2.85 3.06 3.08 1.39 2.58 4.08 4.36 3.89 3.58 2.67 3.23 3.08 2.97 3.01 3.17 3.27 1.49 2.77 4.37 4.67 4.17 3.82 2.93 3.43 3.26 3.12 3.12 3.23 3.43 1.57 2.91 4.58 4.90 4.38 4.01 3.17 3.56 3.37 3.21 3.16 3.20 3.51 1.54 2.83 4.43 4.74 4.24 3.87 3.25 3.35 3.16 2.95 2.80 2.68 3.20 (2) (2) (2) (2) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 1.75 (44.5) 2.25 (67.2) 2.88 (73.2) 3.50 (88.9) 4.50 (114.3) 6.00 (152.4) — 8.50 (215.9) 4.75 (120.7) 5.50 (139.7) 6.50 (165.1) 8.50 (215.9) 2.34 2.44 2.58 2.71 2.12 1.66 1.30 1.06 0.77 — 0.55 0.49 0.44 0.36 0.30 1.13 1.13 1.16 1.17 0.98 0.77 0.64 0.56 0.44 — 0.35 0.27 0.30 0.15 0.21 2.60 2.69 2.83 2.95 2.30 1.83 1.45 1.20 0.89 — 0.65 0.56 0.53 0.39 0.37 0.69 1.26 1.96 2.67 2.58 2.56 2.34 2.37 2.27 — 2.15 2.07 2.33 1.76 2.49 0.77 1.40 2.18 2.98 2.88 2.85 2.59 2.60 2.48 — 2.34 2.28 2.51 1.97 2.69 0.84 1.52 2.39 3.28 3.17 3.11 2.82 2.66 2.50 — 2.50 2.46 2.67 2.17 2.86 0.90 1.64 2.58 3.55 3.44 3.35 3.03 3.01 2.83 — 2.64 2.62 2.80 2.35 3.00 0.95 1.74 2.74 3.78 3.67 3.56 3.20 3.17 2.96 — 2.75 2.76 2.90 2.51 3.11 0.99 1.82 2.87 3.97 3.86 3.72 3.33 3.29 3.05 — 2.82 2.86 2.96 2.63 3.17 1.01 1.86 2.94 4.08 3.98 3.80 3.39 3.32 3.07 — 2.81 2.89 2.93 2.71 3.15 0.91 1.69 2.68 3.76 3.67 3.45 3.04 2.94 2.66 — 2.39 2.54 2.44 2.49 2.63 Notes: 1. For plug-in distributed loads, divide voltage drop values by 2. 2. To determine voltage drop line-to-neutral, multiply lineto-line values by 0.577. 3. Actual voltage drop for different lengths and at loadings less than full rated current can be calculated using the formula: Vd (actual) = Vd (table) x actual load x actual length (ft) rated load 100 feet 14-24 Voltage Drop - Concentrated Loads, Line-to-Line per 100 feet at 100% Rated Load, 35°C Ambient 햸 Power Factor 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 4. For 50 Hz, multiply reactance (X) by 0.85 and resistance values do not change. For 400 Hz, multiply reactance by 3.75 and multiply resistance by 1.4. Calculate new voltage drop: Vd = amps load x 앀3(Rcos θ + X sin θ) per 100 ft, where cos θ = Power Factor. 5. For metric conversion R, X, Z values ”in Ohms per meters Line to Neutral” R x .0328 X x .0328 Z x .0328 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6. For metric conversion ”Line to Line per meter at 25° C ambient in mV/A/m” (Vd 32.8) / A Divide Vd by 2 for distributed loads. 7. Voltage Drop will decrease in lower ambient temperature. Contact Siemens for Voltage Drop in other ambient conditions. Busway Systems Technical Data Technical Ground Capacity Ampere Rating A L-Rated 225 — 400 — 600 — 800 400 1000 600 1200 800 1350 1000 1600 1200 2000 1350,1600 2500 2000 3000 2500 3200 2000 4000 3000,3200 Integral (Hsg.) Ground In2 (mm2) % of % of Internal Ground UL Req Phase Bar R X Z Housing Ground R X Z 1.75 1.75 1.75 2.38 3.25 4.38 5.38 6.50 8.75 5.63 6.75 7.50 9.00 (44.5) (44.5) (44.5) (60.5) (82.6) (111.1) (136.5) (165.1) (222.3) (142.9) (171.5) (190.5) (228.6) 1 1 1 1 1 1 1 1 1 2 2 2 2 0.08 0.17 0.17 0.17 0.20 0.23 0.29 0.29 0.35 0.52 0.59 0.81 0.81 (53.5) (107.1) (107.1) (107.1) (126.5) (146.5) (189.7) (189.7) (227.7) (332.3) (380.0) (522.6) (522.6) 0.22 0.22 0.22 0.30 0.41 0.55 0.67 0.81 1.09 1.41 1.69 1.88 2.25 (141.1) (141.1) (141.1) (191.9) (262.1) (352.8) (433.5) (524.2) (705.6) (907.3) (1088.7) (1209.7) (1451.6) 2.30 2.30 2.30 2.40 2.54 2.72 2.88 3.06 3.42 3.85 4.20 4.44 4.92 (1485.1) (1485.1) (1485.1) (1550.1) (1639.9) (1756.6) (1859.8) (1975.4) (2207.7) (2480.7) (2711.9) (2866.8) (3176.5) 1333 667 667 688 607 552 446 467 425 320 301 229 250 253 253 253 192 147 115 9 84 69 59 53 51 50 10.267 10.267 10.267 8.063 7.208 6.358 5.561 4.837 3.735 3.169 2.848 2.648 2.446 9.037 9.037 9.037 7.333 6.628 5.852 5.115 4.489 3.467 2.955 2.683 2.493 2.339 4.872 4.872 4.872 3.351 2.833 2.487 2.182 1.801 1.390 1.145 0.954 0.894 0.715 14.200 14.200 14.200 11.150 9.202 7.625 6.478 5.687 4.565 4.129 3.835 3.614 3.500 12.963 12.963 12.963 10.000 8.442 6.926 5.883 5.206 4.267 3.837 3.635 3.428 3.378 5.797 5.797 5.797 4.932 3.662 3.189 2.713 2.289 1.623 1.526 1.221 1.144 0.916 1.75 1.75 1.75 1.75 2.25 2.88 3.50 4.50 6.00 6.50 8.50 4.75 5.50 6.50 8.50 (44.5) (44.5) (44.5) (44.5) (57.2) (73.0) (88.9) (114.3) (152.4) (165.1) (215.9) (120.7) (139.7) (165.1) (215.9) 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 0.05 0.11 0.11 0.11 0.13 0.18 0.24 0.24 0.29 0.29 0.35 0.41 0.59 0.59 0.71 (33.5) (67.7) (67.7) (67.7) (85.2) (114.2) (152.3) (152.3) (189.7) (189.7) (227.7) (265.8) (380.0) (380.0) (456.1) 0.22 0.22 0.22 0.22 0.28 0.36 0.44 0.56 0.75 0.81 1.06 1.19 1.38 1.63 2.13 (141.1) (141.1) (141.1) (141.1) (181.5) (231.9) (282.3) (362.9) (483.9) (524.2) (685.5) (766.1) (887.1) (1048.4) (1371.0) 2.30 2.30 2.30 2.30 2.38 2.48 2.58 2.74 2.98 3.06 3.38 3.56 3.80 4.12 4.76 (1485.1) (1485.1) (1485.1) (1485.1) (1536.7) (1601.8) (1665.8) (1769.0) (1923.8) (1975.4) (2181.9) (2290.0) (2453.9) (2660.3) (3073.2) 2128 1054 1054 1054 860 661 510 534 457 467 421 376 277 296 278 261 261 261 261 207 166 140 113 90 84 70 66 60 54 50 7.380 7.380 7.380 7.380 6.715 6.186 5.704 4.719 3.507 4.837 2.294 2.117 1.938 1.688 1.360 6.330 6.330 6.330 6.330 5.993 5.676 5.267 4.323 3.181 4.489 2.020 1.874 1.691 1.500 1.218 3.803 3.803 3.803 3.803 3.029 2.460 2.188 1.893 1.476 1.801 1.087 0.984 0.947 0.773 0.606 11.338 11.338 11.338 11.338 10.194 8.996 8.000 7.411 6.422 5.687 3.072 4.859 4.353 3.334 1.989 10.083 10.083 10.083 10.083 9.191 8.212 7.492 6.880 6.032 5.206 5.419 4.631 4.129 3.060 1.783 5.183 5.183 5.183 5.183 4.409 3.674 2.807 2.756 2.205 2.289 1.764 1.470 1.378 1.323 0.882 Grd. Circuit Characteristics under Fault Conditions Ohms x 103 per 100 ft Note: Bus bar thickness = .25 in. (6.4mm), Ground bar thickness = .125 in.(3.18mm) UL Short Circuit Ratings Ampere AL 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 Rating L-Rated — — — 400 600 800 1000 1200 1350,1600 2000 2500 2000 3000,3200 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 UL Series Connected with Fuse RMS Symmetrical (kA) 6 cycle 1 sec. 3 sec. Maximum Fuse Size for 200kA RMS Symmetrical Rating Class R Class J & T Class L 85 85 85 100 100 125 150 150 150 200 200 200 200 28 28 28 47 50 60 75 90 110 130 160 160 200 16 16 16 27 29 35 43 52 64 75 92 92 115 600 600 600 — — — — — — — — — — 600 600 600 800 — — — — — — — — — J&T J&T J&T T — — — 1200 3000 3000 3000 3000 5000 5000 — — — 85 85 85 85 100 100 100 125 150 150 150 200 200 200 200 40 40 40 40 50 65 80 95 115 90 130 175 175 200 200 23 23 23 23 29 38 46 55 66 52 75 101 101 115 115 600 600 600 — — — — — — — — — — — — 600 600 600 800 — — — — — — — — — — — J&T J&T J&T T — — — 1600 3000 3000 3000 4000 5000 3000 5000 — — — — Sentron Busway has UL approved Series Ratings. By using the appropriate line side fuse, short circuit ratings can be enhanced to 200kA for lower amperage busway. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-25 BUSWAY SYSTEMS M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Sectional Area 50% Internal Ground Bar In2 (mm2) 14 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 Effective Current Carrying Capacity of Housing Min. CSA for Ground Bus Bus Bar Bars per UL 857 Width per Table 14 Inches (mm) Pole In2 (mm2) Busway Systems Straight Sections—Plug-In, Riser and Feeder Straight Sections Sentron Busway can be ordered with Aluminum or Copper bus bars. Aluminum bars are available in 225-4000 ampere sections. Copper bars are available in 225-5000 ampere sections. Sentron Busway includes an integral housing ground, and is available with an internal ground bar or an isolated ground bar in all ampere ratings. Sentron Busway housing is a four-piece aluminum design. BUSWAY SYSTEMS 14 Plug-In Sections Sentron plug-in sections are designed with plug-in openings centered on 24 in. (610mm) intervals, and are located on both sides of the busway for optimum utilization. Plug-in sections are available in standard lengths of 4 ft. (1.22m), 6 ft. (1.83m), 8 ft. (2.44m) and 10 ft. (3.05m). Sentron plug-in sections meet IP40 (indoor) and IP55 (splash proof) requirements. One joint stack assembly is provided with each plug-in section. Riser Sections Sentron Riser sections are designed with plug-in openings centered on 24 in. (610mm) intervals on one side of the busway only. This eliminates unusable plug-in outlets in vertical applications. Riser busway is available in standard lengths of 4 ft. (1.22m), 6 ft. (1.83m), 8 ft. (2.44m) and 10 ft. (3.05m). Sentron Riser Busway is available in IP40 (indoor) and IP55 (splash proof). One joint stack assembly is provided with each riser section. Plug-In Outlet Features The plug-in outlet molded guard design prevents incidental finger contact with live conductors. Sentron plug-in outlets Standard Plug-In Section (Standard plug-in outlets on both sides on 24 in. centers) Suffix PL04 (4 ft.), PL06 (6 ft.), PL08 (8 ft.), PL10 (10 ft.) Standard Riser Section (Standard Plug-In outlets on one side on 24 in. centers) Suffix RI04 (4 ft.), RI06 (6 ft.), RI08 (8 ft.), RI10 (10 ft.) Standard Feeder Section Suffix F024 - 120 (last 3 digits = length in Inches, 024=24 in., 120=120 in.) 14-26 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Selection are IP 2X rated (with the outlet cover open) which means a .472 in. (12mm) or larger probe is unable to enter a plug-in outlet. The outlet is IP40 Rated with the cover closed and IP55 Rated when configured with gaskets. Feeder Sections Feeder busway carries the current of the busway system from the supply source. Feeder busway does not have plug-in outlets. Sentron Feeder busway is available in custom lengths from 2 ft. (.61m) to 10 ft. (3.05m). Feeder sections are rated as IP40 (Indoor), IP55 (Splash Proof), NEMA 3R (Outdoor), and IP66 (Severe Outdoor). One joint stack assembly is provided with each feeder section. Busway Systems Selection Sentron Busway, Widths and Weights Approximate Weight - lbs per ft. (kg per meter) Dimension Inches (mm) 3Ø, 3-Wire 3Ø, 3-Wire with Internal Ground 3Ø, 4-Wire 3Ø, 4-Wire with Internal Ground 3Ø, 4-Wire 200% Neutral 3Ø, 4-Wire 200% Neutral with Internal Ground “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W2” “W2” “W2” “W2” 3.9 3.9 3.9 4.6 5.4 6.6 7.6 8.7 10.9 13.7 15.8 17.3 20.3 (99) (99) (99) (117) (137) (168) (193) (221) (277) (348) (402) (439) (516) 5 (8) 5 (8) 5 (8) 6 (9) 7 (10) 8 (12) 9 (13) 10 (15) 13 (19) 15 (22) 17 (25) 18 (27) 22 (33) 5 (8) 5 (8) 5 (8) 6 (9) 7 (11) 9 (13) 10 (15) 11 (17) 14 (21) 17 (25) 19 (28) 20 (30) 25 (37) 6 (9) 6 (9) 6 (9) 7 (10) 8 (12) 9 (14) 11 (16) 12 (18) 15 (23) 8 (27) 21 (31) 23 (34) 27 (40) 6 (9) 6 (9) 6 (9) 7 (10) 8 (12) 10 (15) 11 (17) 13 (19) 16 (24) 20 (30) 23 (34) 25 (37) 30 (44) 7 (10) 7 (10) 7 (10) 7 (11) 9 (13) 11 (16) 12 (18) 14 (21) 18 (26) 22 (33) 25 (37) 27 (40) 32 (48) 7 (10) 7 (10) 7 (10) 8 (11) 9 (14) 11 (17) 13 (19) 15 (22) 19 (28) 23 (34) 27 (40) 29 (43) 35 (52) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W1” “W2” “W2” “W2” “W2” 3.9 3.9 3.9 3.9 4.4 5.1 5.7 6.7 8.2 10.9 10.7 11.8 13.3 15.3 19.3 (99) (99) (99) (99) (112) (130) (145) (170) (208) (277) (272) (300) (335) (389) (491) 9 (13) 9 (13) 9 (13) 9 (13) 10 (15) 12 (18) 14 (21) 17 (26) 22 (32) 13 (19) 30 (44) 33 (49) 37 (55) 43 (64) 56 (83) 10 (14) 10 (14) 10 (14) 10 (14) 11 (17) 14 (20) 16 (24) 19 (29) 25 (37) 14 (21) 34 (50) 37 (55) 2 (63) 50 (75) 4 (95) 10 (16) 10 (16) 10 (16) 10 (16) 12 (19) 15 (23) 17 (26) 22 (32) 28 (41) 5 (23) 38 (56) 42 (63) 48 (72) 56 (83) 72 (107) 11 11 11 11 14 16 19 24 30 16 42 47 53 62 80 12 12 12 12 15 18 21 26 33 18 46 51 58 68 89 13 13 13 13 16 19 23 28 36 19 50 56 64 75 97 (17) (17) (17) (17) (20) (24) (29) (35) (45) (24) (62) (70) (79) (92) (119) (18) (18) (18) (18) (22) (26) (31) (38) (50) (26) (68) (76) (86) (101) (132) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog (19) (19) (19) (19) (23) (29) (34) (42) (54) (28) (74) (83) (95) (112) (145) 14-27 BUSWAY SYSTEMS Rating L-Rated — — — 400 600 800 1000 1200 1250,1600 2000 2500 2000 3000,3200 14 Ampere AL 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 Busway Systems Elbows Selection Sentron Busway elbows provide a simple, convenient method of changing the direction (left, right, up or down) of a busway run. Two elbow styles are offered: elbow stack and elbow section. BUSWAY SYSTEMS 14 Flatwise Elbow Stacks, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A” AL L-Rated 225 — 1.00 (25) 400 — 1.00 (25) 600 — 1.00 (25) 800 400 1.12 (28 1000 600 2.00 (51) 1200 800 2.50 (64) 1350 1000 3.00 (76) 1600 1200 3.50 (89) 2000 1350,1600 4.62 (117) 2500 2000 5.75 (146) 3000 2500 7.00 (178) 3200 2000 7.75 (197) 4000 3000,3200 9.35 (237) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 1.00 1.00 1.00 1.00 1.12 .25 2.00 2.50 3.25 4.62 4.50 5.00 5.75 6.75 8.87 Flatwise Elbow Stacks Flatwise elbow stacks are used for left and right directional changes. When the busway system is mounted flatwise in the horizontal plane (bus bars run parallel to the floor). Flat Suffix ESFR/ESFL (25) (25) (25) (25) (28) (33) (50) (64) (83) (117) (114) (127) (146) (171) (225) Note: Flatwise elbow stacks can be ordered as either right-hand (ESFR) or lefthand (ESFL) to follow the same nomen-clature as an elbow section. The construction is identical and interchangeable. Edgewise Elbow Stacks, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A” AL L-Rated 225 — 4.25 (108) 400 — 4.25 (108) 600 — 4.25 (108) 800 400 4.25 (108) 1000 600 4.25 (108) 1200 800 4.25 (108) 1350 1000 4.25 (108) 1600 1200 4.25 (108) 2000 1350,1600 4.25 (108) 2500 2000 4.25 (108) 3000 2500 4.25 (108) 3200 2000 4.25 (108) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 (108) (108) (108) (108) (108) (108) (108) (108) (108) (108) (108) (108) (108) (108) (108) Edgewise Elbow Stacks Edgewise elbow stacks create up and down directional changes. The “A” phase is on the inside of the bend for edge up elbow stacks. The “A” phase is on the outside of the bend for edge down elbow stacks. Edge Down Edge Up Suffix ESED Suffix ESEU Note: Edge up and edge down elbow stacks are not interchangeable. 14-28 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Busway Systems Elbows Selection Flatwise Elbow Sections, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A” ”B” AL L-Rated 225 — 12 (305) 12 (305) 400 — 12 (305) 12 (305) 600 — 12 (305) 12 (305) 800 400 12 (305) 12 (305) 1000 600 12(305) 12 (305) 1200 800 12 (305) 12 (305) 1350 1000 12 (305) 12 (305) 1600 1200 18 (457) 18 (457) 2000 1350,1600 18 (457) 18 (457) 2500 2000 18 (457) 18 (457) 3000 2500 18 (457) 18 (457) 3200 2000 18 (457) 18 (457) 4000 3000,3200 24 (610) 24 (610) 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) (305) Edgewise Elbow Sections, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A” ”B” AL L-Rated 225 — 10 (254) 10 (254) 400 — 10 (254) 10 (254) 600 — 10 (254) 10 (254) 800 400 10 (254) 10 (254) 1000 600 10 (254) 10 (254) 1200 800 10 (254) 10 (254) 1350 1000 10 (254) 10 (254) 1600 1200 10 (254) 10 (254) 2000 1350,1600 10 (254) 10 (254) 2500 2000 10 (254) 10 (254) 3000 2500 10 (254) 10 (254) 3200 2000 10 (254) 10 (254) 4000 3000,3200 10 (254) 10 (254) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Flat Left Suffix ELEF Flat Right Suffix ELFR BUSWAY SYSTEMS M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Flatwise elbow sections are used for left and right directional changes when the busway system is mounted in the horizontal plane (bus bars run parallel to the floor). The joint stack assembly may be moved to the opposite leg to change the orientation from left to right/right to left. 14 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 Flatwise Elbow Sections Edgewise Elbow Sections Edgewise elbow sections create up and down directional changes. The “A”phase bus bar lies on the inside of the bend for edge up elbows. The “A” phase bus bar lies on the outside of the bend for edge down elbows. The joint stack assembly on edgewise elbows can not be moved in order to change orientation from up to down/down to up. Sentron Busway elbow sections are shipped with a joint stack assembly on one end for direct connection to the busway system. Edge Up Edge Down Suffix ELEU Suffix ELED (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) Note : Odd angle elbow flatwise and edgewise elbow sections are available for angles 95° - 175° in 5° increments. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-29 Busway Systems Offsets Selection BUSWAY SYSTEMS 14 Offsets can be utilized to solve difficult contour problems and save space. In applications where space does not allow for two connected elbows, a single offset can bypass an obstruction. All offsets are supplied with one joint stack assembly. Flatwise Offsets, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating *“A” ”B” ”C” AL L-Rated 225 — 12 (305) 5 (127) 12 (305) 400 — 12 (305) 5 (127) 12 (305) 600 — 12 (305) 5 (127) 12 (305) 800 400 12 (305) 5 (127) 12 (305) 1000 600 12 (305) 5 (127) 12 (305) 1200 800 12 (305) 5 (127) 12 (305) 1350 1000 12 (305) 5 (127) 12 (305) 1600 1200 18 (457) 5 (127) 18 (457) 2000 1350,1600 18 (457) 5 (127) 18 (457) 2500 2000 18 (457) 5 (127) 18 (457) 3000 2500 18 (457) 5 (127) 18 (457) 3200 2000 18 (457) 5 (127) 18 (457) 4000 3000,3200 24 (610) 8 (203) 24 (610) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 12 12 12 12 12 12 12 12 12 (305) (305) (305) (305) (305) (305) (305) (305) (305) 5 5 5 5 5 5 5 5 5 (127) (127) (127) (127) (127) (127) (127) (127) (127) 12 12 12 12 12 12 12 12 12 (305) (305) (305) (305) (305) (305) (305) (305) (305) 18 18 18 18 24 (457) (457) (457) (457) (610) 5 5 5 5 8 (127) (127) (127) (127) (203) 18 18 18 18 24 (457) (457) (457) (457) (610) Edgewise Offsets, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating *“A” ”B” ”C” AL L-Rated 225 — 10 (254) 6 (152) 10 (254) 400 — 10 (254) 6 (152) 10 (254) 600 — 10 (254) 6 (152) 10 (254) 800 400 10 (254) 6 (152) 10 (254) 1000 600 10 (254) 6 (152) 10 (254) 1200 800 10 (254) 6 (152) 10 (254) 1350 1000 10 (254) 6 (152) 10 (254) 1600 1200 10 (254) 6 (152) 10 (254) 2000 1350,1600 10 (254) 6 (152) 10 (254) 2500 2000 10 (254) 6 (152) 10 (254) 3000 2500 10 (254) 6 (152) 10 (254) 3200 2000 10 (254) 6 (152) 10 (254) 4000 3000,3200 10 (254) 6 (152) 10 (254) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 (152) (152) (152) (152) (152) (152) (152) (152) (152) (152) (152) (152) (152) (152) (152) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) Flat Right Suffix OFFR Flat Left Suffix OFFL Edge Up Suffix OFEU Edge Down Suffix OFED *Note: Leg Dimensions A and C have been reversed from prior publications. 14-30 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Busway Systems Combinations Selection Combinations are used to create edge to flat and flat to edge changes in the busway run. One joint stack assembly is shipped with combination. Flat Right - Edge Up Flat Left - Edge Up Suffix CORU Suffix COLU Edge Up - Flat Left Edge Up - Flat Right Suffix COUL Suffix COUR Flat Right - Edge Down Flat Left - Edge Down Suffix CORD Suffix COLD See drawings for minimum dimensions. Consult Busway Order Service for information on custom lengths. M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) (254) 8 (203) 8 (203) 8 (203) 8 (203) 8 (203) 8 (203) 8 (203) 8 (203) 8 (203) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 16 (406) 12 12 12 12 12 12 12 12 12 18 18 18 18 18 24 (305) (305) (305) (305) (305) (305) (305) (305) (305) (457) (457) (457) (457) (457) (610) BUSWAY SYSTEMS CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 14 Combinations, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating *“A” ”B” ”C” AL L-Rated 225 — 10 (254) 8 (203) 12 (305) 400 — 10 (254) 8 (203) 12 (305) 600 — 10 (254) 8 (203) 12 (305) 800 400 10 (254) 8 (203) 12 (305) 1000 600 10 (254) 8 (203) 12 (305) 1200 800 10 (254) 8 (203) 12 (305) 1350 1000 10 (254) 8 (203) 12 (305) 1600 1200 10 (254) 12 (305) 18 (457) 2000 1350,1600 10 (254) 12 (305) 18 (457) 2500 2000 10 (254) 12 (305) 18 (457) 3000 2500 10 (254) 12 (305) 18 (457) 3200 2000 10 (254) 12 (305) 18 (457) 4000 3000,3200 10 (254) 16 (406) 24 (610) *Note: Leg Dimensions A and C have been reversed from prior publications. Edge Down - Flat Left Edge Down - Flat Right Suffix CODL Suffix CODR Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-31 Busway Systems Tees Selection BUSWAY SYSTEMS 14 Tees are used to simplify directional and plane orientation changes in a busway system. Tees can make 90° bends left or right, and up and down along the busway run. All tees are supplied with two joint stack assemblies. Flatwise Tees, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A”, ”B”, ”C” AL L-Rated 225 — 12 (305) 400 — 12 (305) 600 — 12 (305) 800 400 12 (305) 1000 600 12 (305) 1200 800 12 (305) 1350 1000 12 (305) 1600 1200 18 (457) 2000 1350,1600 18 (457) 2500 2000 18 (457) 3000 2500 18 (457) 3200 2000 18 (457) 4000 3000,3200 24 (610) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 12 12 12 12 12 12 12 12 12 18 18 18 18 18 24 (305) (305) (305) (305) (305) (305) (305) (305) (305) (457) (457) (457) (457) (457) (610) Edgewise Tees, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “D” AL L-Rated 225 — 13 (330) 400 — 13 (330) 600 — 13 (330) 800 400 13 (330) 1000 600 13 (330) 1200 800 18 (457) 1350 1000 18 (457) 1600 1200 18 (457) 2000 1350,1600 18 (457) 2500 2000 27 (686) 3000 2500 27 (686) 3200 2000 27 (686) 4000 3000,3200 29 (737) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 12.0" M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Flatwise Tees Flatwise tees are used to create left and right branches. Flat Right Suffix TEFR Flat Left Suffix TEFL Edgewise Tees Edgewise tees are used to create branches that stem up or down from the busway run. Edge Up Edge Down Suffix TEEU Suffix TEED 13 13 13 13 13 13 13 18 18 18 18 27 27 27 29 (330) (330) (330) (330) (330) (330) (330) (457) (457) (457) (457) (686) (686) (686) (737) (305mm) For Isolated Ground. 14-32 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Busway Systems End Tap Boxes Selection End tap boxes are non-fusible devices used to connect cable and conduit to the end of a busway run or where busway runs connect without the need for over-current protection. End tap boxes may be installed at the end or beginning of a run. Vertical end tap boxes and horizontal end tap boxes can be installed in both horizontal and vertical applications. Extended end tap boxes are available if the application requires additional wire bending space. One joint stack assembly is shipped with each end tap box. Horizontal End Tap Box Standard and Extended Horizontal End Tap Boxes, Dimensions Cable Lugs Per Phase & Neutral Qty. Size 13 13 13 13 13 18 18 18 18 27 27 27 29 (330) (330) (330) (330) (330) (457) (457) (457) (457) (686) (686) (686) (737) 30 30 30 30 30 32 33 33 33 33 33 33 33 (762) (762) (762) (762) (762) (813) (838) (838) (838) (838) (838) (838) (838) 34 34 34 34 34 37 37 37 37 37 37 37 37 (863) (863) (863) (863) (863) (940) (940) (940) (940) (940) (940) (940) (940) 17 17 17 17 17 20 20 20 20 20 20 20 20 (432) (432) (432) (432) (432) (508) (508) (508) (508) (508) (508) (508) (508) 21 21 21 21 21 24 24 24 24 24 24 24 24 (533) (533) (533) (533) (533) (610) (610) (610) (610) (610) (610) (610) (610) 1 1 2 3 4 4 4 6 6 8 9 9 12 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 13 13 13 13 13 13 13 18 18 18 18 27 27 27 29 (330) (330) (330) (330) (330) (330) (330) (457) (457) (457) (457) (686) (686) (686) (737) 30 30 30 30 30 33 33 33 33 33 33 33 33 33 33 (762) (762) (762) (762) (762) (838) (838) (838) (838) (838) (838) (838) (838) (838) (838) 34 34 34 34 34 37 37 37 37 37 37 37 37 37 37 (863) (863) (863) (863) (863) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) 17 17 17 17 17 20 20 20 20 20 20 20 20 20 20 (432) (432) (432) (432) (432) (508) (508) (508) (508) (508) (508) (508) (508) (508) (508) 21 21 21 21 21 24 24 24 24 24 24 24 24 24 24 (533) (533) (533) (533) (533) (610) (610) (610) (610) (610) (610) (610) (610) (610) (610) 1 1 2 3 4 4 4 5 6 5 8 9 9 12 15 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Ground Lugs 1 1 1 1 1 1 1 2 2 2 2 2 3 1 1 1 1 1 1 1 1 2 1 2 2 2 3 4 Vertical End Tap Box Standard and Extended Vertical End Tap Boxes, Dimensions Cable Lugs Per Phase & Neutral Qty. Size Ampere Rating AL L-Rated 225 — 400 — 600 — 800 400 1000 600 1200 800 1350 1000 1600 1200 2000 1350,1600 2500 2000 3000 2500 3200 2000 4000 3000,3200 Dimensions Inches (mm) "A" "B" Std. "B" Ext. Wire Bend Space "C" Std. "C" Ext. 13 13 13 13 13 18 18 18 18 27 27 29 29 (330) (330) (330) (330) (330) (457) (457) (457) (457) (686) (686) (737) (737) 25 25 25 25 25 32 28 28 28 28 28 28 28 (635) (635) (635) (635) (635) (813) (711) (711) (711) (711) (711) (711) (711) 29 29 29 29 29 32 32 32 32 32 32 32 32 (737) (737) (737) (737) (737) (813) (813) (813) (813) (813) (813) (813) (813) 17 17 17 17 17 20 20 20 20 20 20 20 20 (432) (432) (432) (432) (432) (508) (508) (508) (508) (508) (508) (508) (508) 21 21 21 21 21 24 24 24 24 24 24 24 24 (533) (533) (533) (533) (533) (610) (610) (610) (610) (610) (610) (610) (610) 1 1 2 3 4 4 4 6 6 8 9 9 12 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 13 13 13 13 13 13 13 18 18 18 18 27 27 27 29 (330) (330) (330) (330) (330) (330) (330) (457) (457) (457) (457) (686) (686) (686) (737) 25 25 25 25 25 28 28 28 28 28 28 28 28 28 28 (635) (635) (635) (635) (635) (711) (711) (711) (711) (711) (711) (711) (711) (711) (711) 29 29 29 29 29 32 32 32 32 32 32 32 32 32 32 (737) (737) (737) (737) (737) (813) (813) (813) (813) (813) (813) (813) (813) (813) (813) 17 17 17 17 17 20 20 20 20 20 20 20 20 20 20 (432) (432) (432) (432) (432) (508) (508) (508) (508) (508) (508) (508) (508) (508) (508) 21 21 21 21 21 24 24 24 24 24 24 24 24 24 24 (533) (533) (533) (533) (533) (610) (610) (610) (610) (610) (610) (610) (610) (610) (610) 1 1 2 3 4 4 4 5 6 5 8 9 9 12 15 #6 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 AWG -350 kcmil, Cu/AI. Suffix ETHS (Standard) Suffix ETHX (Extended) BUSWAY SYSTEMS Wire Bend Space "C" Std. "C" Ext. 14 Ampere Rating AL L-Rated 225 — 400 — 600 — 800 400 1000 600 1200 800 1350 1000 1600 1200 2000 1350,1600 2500 2000 3000 2500 3200 2000 4000 3000,3200 Dimensions Inches (mm) "A" "B" Std. "B" Ext. #4 AWG -600 kcmil, Cu/AI. Ground Lugs Suffix ETVS (Standard) Suffix ETVX (Extended) 1 1 1 1 1 1 1 2 2 2 2 2 3 1 1 1 1 1 1 1 1 2 1 2 2 2 3 4 24.0" (610mm) for isolated ground. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-33 Busway Systems Center Tap Boxes Selection Center tap boxes are non-fusible devices utilized to feed to or take off power from the busway run. When loads served by the busway run do not require over-current protection, center tap boxes may be used. If the application requires additional wiring bending space, extended center tap boxes are available. One joint stack assembly is provided with each center tap box. BUSWAY SYSTEMS 14 Standard and Extended Center End Tap Boxes, Dimensions Ampere Rating AL L-Rated 225 — 225 — 400 — 600 — 800 400 1000 600 1200 800 1350 1000 1600 1200 2000 1350,1600 2500 2000 3000 2500 3200 2000 4000 3000,3200 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000, 3200 4000 Dimensions Inches (mm) "A"Std. "B" "D" Wire Bend Space "A" Ext.. "C" Std. "C" Ext. Cable Lugs Per Phase & Neutral Qty. Size 25 25 25 25 25 25 29 29 33 33 37 37 37 45 (635) (635) (635) (635) (635) (635) (737) (737) (838) (838) (940) (940) (940) (1143) 16 16 16 16 16 16 16 16 20 20 24 24 24 28 (406) 3.9 (406) 3.9 (406) 3.9 (406) 3.9 (406) 4.2 (406) 4.6 (406) 5.2 (406) 5.7 (508) 6.3 (508) 7.4 (610) 8.7 (610) 9.7 (610) 9.7 (711) 11.9 (99) (99) (99) (99) (107) (117) (132) (145) (160) (188) (221) (246) (246) (302) 29 29 29 29 29 29 33 33 37 37 41 41 41 49 (737) (737) (737) (737) (737) (737) (838) (838) (940) (940) (1041) (1041) (1041) (1245) 17 17 17 17 17 17 20 20 20 20 20 20 20 20 (432) (432) (432) (432) (432) (432) (508) (508) (508) (508) (508) (508) (508) (508) 21 21 21 21 21 21 24 24 24 24 24 24 24 24 (533) (533) (533) (533) (533) (533) (610) (610) (610) (610) (610) (610) (610) (610) 1 1 1 2 3 4 4 4 5 6 8 9 9 12 25 25 25 25 25 29 29 29 29 33 33 33 33 (635) (635) (635) (635) (635) (737) (737) (737) (737) (838) (838) (838) (838) 30 30 30 30 30 33 33 20 20 20 24 24 24 (762) (762) (762) (762) (762) (838) (838) (508) (508) (508) (610) (610) (610) (99) (99) (99) (107) (107) (114) (122) (135) (155) (160) (185) (201) (201) 29 29 29 29 29 33 33 33 33 37 37 37 37 (737) (737) (737) (737) (737) (838) (838) (838) (838) (940) (940) (940) (940) 17 17 17 17 18 22 21 21 20 20 23 20 20 (432) (432) (432) (432) (457) (559) (533) (533) (508) (508) (584) (508) (508) 21 21 21 21 22 26 25 25 24 24 17 24 24 (533) (533) (533) (533) (559) (660) (635) (635) (610) (610) (432) (610) (610) 1 1 2 3 4 4 4 5 6 5 8 9 9 12 15 37 (940) 40(1016) 3.9 3.9 3.9 4.2 4.2 4.5 4.8 5.3 6.1 6.3 7.3 7.9 7.9 28 (711) 9.4 (239) 34 (863) 11.7(297) 41 (1041) 44 (1118) 20 (508) 19 (483) 24 (610) 23 (584) Center Tap Box Suffix CTBS (Standard) Suffix CTBX (Extended) #6 AWG -350 kcmil, Cu/AI. #4 AWG -600 kcmil, Cu/AI. 24.0" (610mm) for isolated ground. 14-34 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Ground Lugs 1 1 1 1 1 1 1 1 1 2 2 2 2 3 1 1 1 1 1 1 1 1 2 1 2 2 2 3 4 Busway Systems In-Line Disconnect Cubicles and Expansion Fittings In-Line Disconnect Cubicles In-Line Disconnect Cubicle, Dimensions Description of Unit Type of Disconnect Fusible Switch Selection Dimensions Inches (mm) “A” “B” “C” 400-600A FK Visible Blade 800-1200A Vacu-Break JD6, LD6, MD6, ND6 PD6, RD6 SJD6, SLD6, SMD6, SND6 SPD6 1600A Frame 36 36 36 36 36 36 Molded Case Circuit Breaker Digital Sentron Series MCCB's Power 200-5000A WL Circuit Breaker Bolted Pressure 800A Switch 1200-2500A 3000A 4000A ACCESScompatible (914) (914) (914) (914) (914) (914) 28 36 28 36 28 36 (711) (914) (711) (914) (711) (914) 28 32 28 32 28 32 (711) (813) (711) (813) (711) (813) 48 (1219) 36 (914) 32 (813) 33 37 37 41 36 40 40 40 32 32 48 48 (838) (940) (940) (1041) (914) (1016) (1016) (1016) (813) (813) (1219) (1219) Cubicles provide a means of mounting switches or circuit breakers where power feeds to or pulls from the busway system. When bolted connections are preferred, cubicles may be used in place of plug-in units. Cubicles can also be used at ampere ratings that exceed standard plug-in unit ratings. Modifications to cubicles can be made in order to accommodate key inter-locks, ground fault detector systems and power monitoring systems. In-Line Disconnect Cubicle Note: Consult your local Siemens sales office for details on WL breakers. 14 BUSWAY SYSTEMS Horizontal Vertical Expansion Fittings, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A” AL L-Rated 225 — 13 (330) 400 — 13 (330) 600 — 13 (330) 800 400 13 (330) 1000 600 13 (330) 1200 800 18 (457) 1350 1000 18 (457) 1600 1200 18 (457) 2000 1350,1600 18 (457) 2500 2000 23 (584) 3000 2500 23 (584) 3200 2000 23 (584) 4000 3000,3200 25 (635) Expansion Fittings CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 Expansion Fitting Suffix XPFT 24.0" M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 13 13 13 13 13 13 13 18 18 18 18 23 23 23 25 (330) (330) (330) (330) (330) (330) (330) (457) (457) (457) (457) (584) (584) (584) (635) Expansion fittings accommodate for expansion and contraction of a busway run and building movement. Expansion fittings typically are installed in the center of long busway runs, and at the beginning of riser runs to minimize stress on the lower most device or where a busway run crosses an expansion joint of a building. Expansion Fittings are recommended when the run exceeds 200 ft. (608m). Expansion fittings allow for a +/- 2 in. (50.8mm) movement along the length of the busway system. (610mm) for isolated ground. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-35 Busway Systems Reducers and Phase Rotation Fittings BUSWAY SYSTEMS 14 Fused Reducers, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A” AL L-Rated 225 — 11.4 (289) 400 — 11.4 (289) 600 — 11.4 (289) 800 400 11.4 (289) 1000 600 11.4 (289) 1200 800 12.5 (318) 1350 1000 13.5 (343) 1600 1200 14.6 (372) 2000 1350,1600 16.9 (429) 2500 2000 19.6 (498) 3000 2500 21.3 (541) 3200 2000 22.9 (582) 4000 3000,3200 31.5 (800) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 10.4 10.4 10.4 10.4 10.4 11.0 11.6 12.6 14.1 14.6 16.6 17.9 18.9 20.9 31.5 (264) (264) (264) (264) (264) (280) (296) (321) (359) (372) (423) (455) (480) (531) (800) Phase Rotation Fittings, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating “A” AL L-Rated 225 — 7.9 (200) 400 — 7.9 (200) 600 — 7.9 (200) 800 400 8.5 (216) 1000 600 9.4 (239) 1200 800 10.5 (267) 1350 1000 11.5 (293) 1600 1200 12.6 (321) 2000 1350,1600 14.9 (376) 2500 2000 17.6 (447) 3000 2500 19.8 (503) 3200 2000 21.3 (541) 4000 3000,3200 24.3 (617) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 14-36 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Selection Fused Reducers The National Electric Code requires over current protection when busway systems are reduced in ampacity. A fused reducer is used to reduce the allowable ampere rating in those sections of the busway that do not require a higher rating (i.e. at branch circuit junctures). Fused Reducer Suffix RFRF Non-Fused Reducers Non-fused reducers are used in conjunction with the following exception to the Fused Reducer in the National Electric Code: “For industrial establishments only,omission of over current protection shall be permitted at points where busways are reduced in ampacity, provided that the length of the busway having the smaller ampacity does not exceed 50 ft. and has an ampacity of at least equal to onethird the rating or setting of the over current device next back on the line, and provided that such busway is free from contact with combustible material.” Special joint stack connections are provided for non-fused reducer connections. Consult factory for specific design guidelines. Phase-Rotation Fittings Phase-rotation fittings can be used when the application requires a phase rotation in the power supply. Phase rotation fittings can be ordered for “phase and ground”, “phase only” and “ground only” rotations. Phase Rotation Fitting Suffix TRPG, Phase and Ground TRPO, Phase Only TRGO, Ground Only 7.9 (200) 7.9 (200) 7.9 (200) 7.9 (200) 8.4 (213) 9.0 (229) 9.6 (245) 10.6 (270) 12.1 (372) 12.6 (321) 14.6 (200) 15.8 (402) 17.3 (439) 19.3 (490) 23.3 (592) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Phase Rotation Examples Busway Systems Service Heads Selection Service Heads are used to connect busway to a service entrance. In the Sentron Busway line, 3 single-phase service heads and 3-phase service head connections are available. The standard service entrance connection is the 3-phase service head which consists of one service head for all three phases. 3 single-phase service heads consist of three heads – one for each phase and may be used to meet the requirements of certain applications. To ensure ease of installation of incoming cables, both types of Sentron service heads are constructed so that the lugs face the Glastic bottom of the box. The Glastic bottom provides insulation and protection to the incoming cables. Three Single-Phase Service Heads Suffix V1TX Single-Phase Service Heads, Dimensions (standard/min.) 13 13 13 13 13 18 18 18 20 27 29 29 29 (330) (330) (330) (330) (330) (457) (457) (457) (508) (686) (737) (737) (737) 1 1 2 3 4 4 4 5 6 8 9 9 12 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 13 13 13 13 13 13 13 18 20 18 20 27 27 27 29 (330) (330) (330) (330) (330) (330) (330) (457) (508) (457) (508) (686) (686) (686) (737) 1 1 2 3 4 4 4 5 6 5 8 9 9 12 15 Ground Lugs 1 1 1 1 1 1 1 1 2 2 2 2 3 M-Rated 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 1 1 1 1 1 1 1 1 2 1 2 2 2 3 4 Three-Phase Service Head Suffix V3TX Three-Phase Service Heads, Dimensions (standard/min.) Ampere Rating AL L-Rated 225 400 225 600 — 800 400 1000 600 1200 800 1350 1000 1600 1200 2000 1350,1600 2500 2000 3000 2500 3200 2000 4000 3000,3200 Dimensions Inches (mm) Three-Phase “B” Cable Lugs per Phase and Neutral Qty. Size 13 13 13 13 13 18 18 18 18 27 27 27 29 (330) (330) (330) (330) (330) (457) (457) (457) (457) (686) (686) (686) (737) 1 1 2 3 4 4 4 5 6 8 9 9 12 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 13 13 13 13 13 13 13 18 18 18 18 27 27 27 29 (330) (330) (330) (330) (330) (330) (330) (457) (457) (457) (457) (686) (686) (686) (737) 1 1 2 3 4 4 4 5 6 5 8 9 9 12 15 #6 BUSWAY SYSTEMS Dimensions Inches (mm) Single-Phase “A” 14 Ampere Rating AL L-Rated 225 400 225 600 — 800 400 1000 600 1200 800 1350 1000 1600 1200 2000 1350,1600 2500 2000 3000 2500 3200 2000 4000 3000,3200 Cable Lugs per Phase and Neutral Qty. Size Ground Lugs 1 1 1 1 1 1 1 1 2 2 2 2 3 M-Rated 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 AWG - 350 kcmil, Cu / Al. #4 1 1 1 1 1 1 1 1 2 1 2 2 2 3 4 AWG - 600 kcmil, Cu / Al. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-37 Busway Systems Hangers Selection Trapeze Hanger A complete offering of hangers is available to support Sentron Busway in both vertical and horizontal applications. Standard trapeze hangers support Sentron Busway in horizontal applications on 10 ft. (3.05m) centers. Additional hangers may be used if structural requirements mandate their use. The contractor must supply drop rods to complete assembly for trapeze hangers. BUSWAY SYSTEMS 14 Trapeze Hanger, Dimensions and Catalog Numbers “A” Dimensions Flat Mounted Ampere Rating Inches (mm) Catalog Number햲 AL L-Rated 225 — 10.0 (254) SXTH1 400 — 10.0 (254) SXTH1 600 — 10.0 (254) SXTH1 800 400 10.0 (254) SXTH1 1000 600 10.0 (254) SXTH1 1200 800 10.0 (254) SXTH1 1350 1000 13.5 (343) SXTH2 1600 1200 13.5 (343) SXTH2 2000 1350,1600 13.5 (343) SXTH2 2500 2000 13.5 (343) SXTH3 3000 2500 13.5 (343) SXTH3 3200 2000 13.5 (343) SXTH3 4000 3000,3200 23.0 (584) SXTH4 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 햲 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 13.5 13.5 13.5 18.5 18.5 18.5 23.0 (254) (254) (254) (254) (254) (254) (254) (254) (343) (343) (343) (470) (470) (470) (584) SXTH1 SXTH1 SXTH1 SXTH1 SXTH1 SXTH1 SXTH1 SXTH1 SXTH2 SXTH2 SXTH2 SXTH3 SXTH3 SXTH3 SXTH4 Use SXTH1 for Edge Mounted. Flat Mounted Spring Hanger, Catalog Numbers Catalog Assembly floor Ampere Rating 10ft. 12 ft. AL L-Rated 225 — SXSH4 SXSH4 400 — SXSH4 SXSH4 600 — SXSH4 SXSH4 800 400 SXSH4 SXSH4 1000 600 SXSH4 SXSH4 1200 800 SXSH4 SXSH4 1350 1000 SXSH4 SXSH4 1600 1200 SXSH4 SXSH4 2000 1350,1600 SXSH4 SXSH4 2500 2000 SXSH4 SXSH4 3000 2500 SXSH4 SXSH6 3200 2000 SXSH4 SXSH6 4000 3000,3200 SXSH4 SXSH6 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH4 SXSH2 SXSH6 SXSH6 SXSH6 SXSH6 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH4 SXSH6 SXSH8 SXSH8 SXSH8 SXSH10 to ceiling height 14 ft. 16 ft. 18 ft. SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6 SXSH6 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6 SXSH6 SXSH6 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6 SXSH6 SXSH8 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6 SXSH4 SXSH8 SXSH8 SXSH8 SXSH10 SXSH12 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6 SXSH6 SXSH4 SXSH8 SXSH10 SXSH10 SXSH12 SXSH14 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH4 SXSH6 SXSH6 SXSH8 SXSH4 SXSH8 SXSH10 SXSH12 SXSH12 SXSH14 Edge Mounted Spring Hanger Spring hangers and floor support hangers must be used to provide secure mounting of the busway run in vertical applications. Spring hangers support the weight of the busway on each floor and also compensate for minimal building movement and thermal expansion. Maximum distance between spring hangers may not exceed 16 ft. (4.88m). When ordering 18 ft. (5.49m) floor to ceiling height assemblies, intermediate support hangers are necessary. * *Note: Flanges do not offer support to the busway. Flanges provide a means of covering the hole created in the existing structure. 14-38 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Busway Systems Hangers Selection Structural Steel Hanger, Dimensions and Catalog Numbers “A” Dimensions Catalog Ampere Rating Inches (mm) Number AL L-Rated 225 — 10.0 (254) SXSS1 400 — 10.0 (254) SXSS1 600 — 10.0 (254) SXSS1 800 400 10.0 (254) SXSS1 1000 600 10.0 (254) SXSS1 1200 800 10.0 (254) SXSS1 1350 1000 13.5 (343) SXSS2 1600 1200 13.5 (343) SXSS2 2000 1350,1600 13.5 (343) SXSS2 2500 2000 18.5 (470) SXSS3 3000 2500 18.5 (470) SXSS3 3200 2000 18.5 (470) SXSS3 4000 3000,3200 23.0 (584) SXSS4 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 13.5 13.5 13.5 13.5 13.5 13.5 23.0 (254) (254) (254) (254) (254) (254) (254) (254) (343) (343) (343) (343) (343) (343) (584) Single Drop Rod Hanger, Catalog Numbers Ampere Rating Catalog Number AL L-Rated 225 — — 400 — — 600 — SXDRA1 800 400 SXDRA2 1000 600 SXDRA3 1200 800 SXDRA4 1350 1000 SXDRA5 1600 1200 SXDRA6 2000 1350,1600 SXDRA7 2500 2000 — 3000 2500 — 3200 2000 — 4000 3000,3200 — CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 SXSS1 SXSS1 SXSS1 SXSS1 SXSS1 SXSS1 SXSS1 SXSS1 SXSS2 SXSS2 SXSS2 SXSS2 SXSS2 SXSS2 SXSS4 BUSWAY SYSTEMS M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 14 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 Structural Steel Hanger A complete offering of hangers is available to support Sentron Busway in both vertical and horizontal applications. Structural Steel hangers support Sentron Busway in horizontal applications on 10 ft. (3.05m) centers. Additional hangers may be used if structural requirements mandate their use. Single Drop Rod Hanger A complete offering of hangers is available to support Sentron Busway in both vertical and horizontal applications. Single drop rod hangers support Sentron Busway in horizontal applications on 10 ft. (3.05m) centers. Additional hangers may be used if structural requirements mandate their use. The contractor must supply drop rods to complete assembly for single drop rod hangers. — — — SXDRC1 SXDRC2 SXDRC3 SXDRC4 SXDRC5 SXDRC6 SXDRC8 SXDRC7 — — — — Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-39 Busway Systems BUSWAY SYSTEMS 14 Hangers and End Closers Selection Wall Mounted Hanger, Dimensions and Catalog Numbers Dimensions Inches (mm) Ampere Rating “A” ”B” ”C” AL L-Rated 225 — 12.3 (311) 6.1 (156) 4.2 (107) 400 — 12.3 (311) 6.1 (156) 4.2 (107) 600 — 12.3 (311) 6.1 (156) 4.2 (107) 800 400 12.3 (311) 6.1 (156) 3.8 (97) 1000 600 12.3 (311) 6.1 (156) 3.8 (97) 1200 800 12.3 (311) 6.1 (156) 2.8 (72) 1350 1000 16.3 (413) 8.1 (206) 4.4 (111) 1600 1200 16.3 (413) 8.1 (206) 3.9 (98) 2000 1350,1600 16.3 (413) 8.1 (206) 2.8 (70) 2500 2000 20.8 (527) 10.4 (264) 3.6 (92) 3000 2500 20.8 (527) 10.4 (264) 2.5 (64) 3200 2000 20.8 (527) 10.4 (264) 1.8 (46) 4000 3000,3200 25.3 (641) 12.6 (321) 2.5 (64) SXWH1 SXWH1 SXWH1 SXWH1 SXWH1 SXWH1 SXWH2 SXWH2 SXWH2 SXWH3 SXWH3 SXWH3 SXWH4 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 SXWH1 SXWH1 SXWH1 SXWH1 SXWH1 SXWH1 SXWH1 SXWH1 SXWH2 SXWH2 SXWH2 SXWH3 SXWH3 SXWH3 SXWH4 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 12.3 12.3 12.3 12.3 12.3 12.3 12.3 12.3 16.3 16.3 16.3 20.8 20.8 20.8 25.3 (311) (311) (311) (311) (311) (311) (311) (311) (413) (413) (413) (527) (527) (527) (641) 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 8.1 8.1 8.1 10.4 10.4 10.4 12.6 (156) (156) (156) (156) (156) (156) (156) (156) (206) (206) (206) (264) (264) (264) (321) 4.2 4.2 4.2 3.8 3.8 2.8 2.8 2.8 4.4 3.9 2.8 3.6 2.5 1.8 2.5 (107) (107) (107) (97) (97) (72) (72) (72) (111) (98) (70) (92) (64) (46) (64) Catalog Number Wall Mounted Hanger Wall Mounted Hangers are used for horizontal applications close to a wall. The busway can be mounted either edgewise or flatwise to the wall. Wall Mounted Hanger ensures the minimum clearance between the wall and the busway run. End Closers End closers safely terminate a busway run and protect the bus bar ends. End closers may be removed easily in order to extend a busway run. End closers are shipped with Glastic insulation pieces, however, joint stacks and inspection covers are not included. End Closers (Joint stack and covers not included) Suffix ECLS 14-40 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Busway Systems Roof and Wall Flanges Selection Roof, wall and floor flanges are available for Sentron Busway. When the busway run passes thorough a roof, wall or ceiling, a flange should be used. Flanges do not offer support to the busway. Flanges provide a means of covering the hole created in the existing structure. Additional sealant may be required to meet fire codes and all other local requirements. No caulking or gasketing is provided with Sentron flanges. Roof Flanges, Dimensions M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 16 (406) 16 (406) 16 (406) 20.5 (521) 20.5 (521) 20.5 (521) 25 (635) 18 (457) 18 (457) 18 (457) 18 (457) 18 (457) 18 (457) 22 (559) 22 (559) 22 (559) 22 (559) 26.5 (673) 26.5 (673) 31 (787) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 16 (406) 16 (406) 16 (406) 20.5 (521) 20.5 (521) 20.5 (521) 25 (635) 18 (457) 18 (457) 18 (457) 18 (457) 18 (457)) 18 (457) 18 (457) 18 (457) 22 (559) 22 (559) 22 (559) 26.5 (673) 26.5 (673) 26.5 (673) 31 (787) Wall, Ceiling and Floor Flanges, Dimensions Dimensions Inches (mm) Ampere Rating “A” ”B” AL L-Rated 225 — 11 (279) 7 (178) 400 — 11 (279) 7 (178) 600 — 11 (279) 7 (178) 800 400 11 (279) 7 (178) 1000 600 12 (305) 8 (203) 1200 800 13 (330) 9 (229) 1350 1000 14 (356) 10 (254) 1600 1200 15 (381) 11 (279) 2000 1350,1600 17 (432) 13 (330) 2500 2000 20 (508) 16 (406) 3000 2500 22 (559) 18 (457) 3200 2000 24 (610) 20 (508) 4000 3000,3200 26 (660) 22 (559) CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 10 10 10 10 11 12 12 13 15 15 17 18 19 21 26 (254) (254) (254) (254) (279) (305) (305) (330) (381) (381) (432) (457) (483) (533) (660) Roof Flanges Suffix GRFL BUSWAY SYSTEMS CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 Rating L-Rated — — — 400 600 800 1000 1200 1350,1600 2000 2500 2000 3000,3200 Roof Flanges Roof flanges are available for Sentron Busway. When the busway run passes thorough a roof, a flange should be used. Flanges do not offer support to the busway. Flanges provide a means of covering the hole created in the existing structure. Additional sealant may be required to meet fire codes and all other local requirements. No caulking or gasketing is provided with Sentron flanges. Roof flanges provide a watertight seal for use with NEMA 3R and IP66 rated busway. Roof pitch must be indicated on drawings when ordering roof flanges. 14 Ampere AL 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 Dimensions Inches (mm) “A” ”B” Wall, Ceiling and Floor Flanges Wall/Floor flanges are available for Sentron Busway. When the busway run passes thorough a wall or ceiling, a flange should be used. Flanges do not offer support to the busway. Flanges provide a means of covering the hole created in the existing structure. Additional sealant may be required to meet fire codes and all other local requirements. No caulking or gasketing is provided with Sentron flanges. Wall, Ceiling and Floor Flanges Suffix GWFL 6 (152) 6 (152) 6 (152) 6 (152) 7 (178) 8 (203) 8 (203) 9 (229) 11 (279) 11 (279) 13 (330) 14 (356) 15 (381) 17 (432) 22 (559) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-41 Busway Systems Flanged Ends Selection Flanged ends provide a direct connection to low voltage switchgear, switchboards, motor control centers, large power panels, and other electrical distribution equipment. Flanged ends are shipped with one joint stack assembly. The switchgear manufacture supplies lugs and mounting hardware. See illustration for flanged end drilling patterns. BUSWAY SYSTEMS 14 Flanged End, Dimensions Ampere AL 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 3200 4000 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 Rating L-Rated — — — 400 600 800 1000 1200 1350,1600 2000 2500 2000 3000,3200 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Dimensions Inches (mm) Fig. “W” No. 1.75 1.75 1.75 2.38 3.25 4.38 5.38 6.50 8.75 5.63 6.75 6.75 9.00 (44.4) (44.4) (44.4) (60.5) (82.6) (111.3) (136.7) (165.1) (222.3) (143.0) (171.5) (171.5) (228.6) 1 1 1 1 1 1 1 1 1 2 2 2 2 1.75 1.75 1.75 1.75 2.25 2.88 3.50 4.50 6.00 6.50 8.50 4.75 5.50 6.50 8.50 (44.4) (44.4) (44.4) (44.4) (57.2) (73.2) (88.9) (114.3) (152.4) (165.1) (215.9) (120.7) (139.7) (165.1) (215.9) 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 Flanged End Suffix FRND Figure 1 Figure 2 Flanged End Bus Bar Drilling Pattern (NEMA) (Same pattern for 2 bus bars per pole, see figure 2 above.) Other See drilling patterns are available and must be specified at order entry. Figures 4, 5 and 6 on page 14-43. 14-42 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Busway Systems Flanged Ends Selection ”B” ”C” 10.0 (254) 10.0 (254) 10.0 (254) 10.0 (254) 10.0 (254) 15.50 (395) 15.50 (395) 15.50 (395) 15.50 (395) 20.0 (508) 20.0 (508) 24.0 (610) 24.0 (610) 8.00 (203) 8.00 (203) 8.00 (203) 8.00 (203) 8.00 (203) 13.50 (343) 13.50 (343) 13.50 (343) 13.50 (343) 18.00 (457) 18.00 (457) 22.0 (569) 22.0 (569) 4.38 4.38 4.38 4.38 4.38 7.13 7.13 7.13 7.13 4.50 4.50 5.50 5.50 (111) (111) (111) (111) (111) (181) (181) (181) (181) (114) (114) (140) (140) 1.94 1.94 1.94 1.94 1.94 1.60 2.10 2.66 3.78 0.68 0.68 0.68 0.68 (49) (49) (49) (49) (49) (41) (53) (67) (96) (17) (17) (17) (17) 3.88 3.88 3.88 3.88 2.06 3.19 4.19 5.31 7.56 1.37 1.37 1.37 1.37 CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 10.0 (254) 10.0 (254) 10.0 (254) 10.0 (254) 10.0 (254) 10.0 (254) 10.0 (254) 15.50 (395) 15.50 (395) 15.50 (395) 15.50 (395) 20.0 (508) 20.0 (508) 20.0 (508) 24.0 (610) 8.00 8.00 8.00 8.00 8.00 8.00 8.00 13.50 13.50 13.50 13.50 18.00 18.00 18.00 22.00 4.38 4.38 4.38 4.38 4.38 4.38 4.38 7.13 7.13 7.13 7.13 4.50 4.50 4.50 5.50 (111) (111) (111) (111) (111) (111) (111) (181) (181) (181) (181) (114) (114) (114) (140) 1.63 1.63 1.63 1.63 1.88 0.85 1.16 1.66 2.41 2.66 3.66 0.68 0.68 0.68 0.68 (41) (41) (41) (41) (48) (21) (29) (42) (42) (67) (93) (17) (17) (17) (17) 3.25 3.25 3.25 3.25 3.75 1.69 2.31 3.31 4.81 5.31 7.31 1.37 1.37 1.37 1.37 M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Figure 1 1.75 1.75 1.75 1.75 2.25 2.88 3.50 4.50 6.00 6.50 8.50 4.75 5.50 6.50 8.50 (44.4) (44.4) (44.4) (44.4) (57.2) (73.2) (88.9) (114.3) (152.4) (165.1) (215.9) (120.7) (139.7) (165.1) (215.9) 1 1 1 1 1 2 2 2 2 2 1 3 3 3 3 (203) (203) (203) (203) (203) (203) (203) (343) (343) (343) (343) (457) (457) (457) (569) ”D” Figure 2 ”E” ”F” ”G” Fig. No. (99) (99) (99) (99) (52) (81) (106) (135) (192) (36) (36) (36) (36) — — — — — — — — — 4.44 5.56 6.32 7.81 (113) (141) (161) (198) 6.00 (152) 6.00 (152) 6.00 (152) 6.00 (152) 6.00 (152) 8.50 (216) 8.50 (216) 8.50 (216) 8.50 (216) 13.25 (337) 13.25 (337) 13.25 (337) 14.25 (362) 4, 5 4, 5 4, 5 4, 5 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 (83) (83) (83) (83) (95) (43) (59) (84) (122) (135) (186) (36) (36) (36) (36) — — — — — — — — — — — 3.56 4.32 5.31 7.31 (90) (110) (135) (186) 6.00 (152) 6.00 (152) 6.00 (152) 6.00 (152) 6.00 (152) 6.00 (152) 6.00 (152) 8.50 (216) 8.50 (216) 8.50 (216) 8.50 (216) 13.25 (337) 13.25 (337) 13.25 (337) 14.25 (362) 4, 5 4, 5 4, 5 4, 5 4, 5 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 4, 6 Figure 3 Integral and Internal Ground Strap Drilling Detail Figure 4 Figure 5 Figure 6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-43 BUSWAY SYSTEMS “A” 14 Flanged End, Dimensions (standard/min.) Dimensions Inches (mm) Ampere Rating Ref. Bar Width Fig. No. AL L-Rated 225 — 2.38 (60.5) 1 400 — 2.38 (60.5) 1 600 — 2.38 (60.5) 1 800 400 2.38 (60.5) 1 1000 600 3.25 (82.6) 2 1200 800 4.38 (111.3) 2 1350 1000 5.38 (136.7) 2 1600 1200 6.50 (165.1) 2 2000 1350,1600 8.75 (222.3) 2 2500 2000 5.63 (143.0) 3 3000 2500 6.75 (171.5) 3 3200 2000 7.50 (190.5) 3 4000 3000,3200 9.00 (228.6) 3 Busway Systems Panelboards and Meter Center Modules Meter center modules provide a quick and convenient method of connecting to metering devices for both commercial and industrial applications. Dimensional Data Required Dimensions Inches (mm) “A” Distance between floor and bottom of meter center as required by the customer. “B” Dimension from bottom of meter center to centerline of meter center joint connection stack: 100-125A Panel, B = 16.5 (419) 200A Panel, B = 22.0 (559) “C” Equals “A” plus “B”, Minimum 16.0 (406) “D” Individual meter center height. Consult Modular Metering application information. BUSWAY SYSTEMS 14 Meter center modules connect at the side of a busway run to special joint stacks; these special joints can be added to existing busway to accommodate meter center module connections. When using multiple metering stacks, main disconnects are available if the system reaches the 6 circuit rule (see metering bulletin for further information). 14-44 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Selection Busway Systems Selection Meter Center Cubicles Meter center cubicles provide a quick and convenient method of connecting to metering devices for both commercial and industrial applications and have the main disconnect circuit breaker factory installed. Having the main disconnect built into the device reduces the required space on the right and left side of the busway. Meter center modules connect at the side of the cubicle frame box using an SBJ4 stack. Meter center cubicles are available for 600 – 1200 Amp (L, M and N Frames). They are available with flexible meter center connections, left side, right side or both. (When ordering a meter center cubicle a SBJ4 stack must be ordered separately.) M-Rated — — — 400 — 600 800 1000 1200,1350 1600 2000 — — 2500,3000,3200 4000 Meter Center Module 3.9 3.9 3.9 3.9 4.4 5.1 5.7 6.7 8.2 8.7 10.7 11.8 13.3 15.3 19.3 (99) (99) (99) (99) (112) (130) (145) (170) (208) (221) (272) (300) (335) (389) (491) 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 (813) (813) (813) (813) (813) (813) (813) (813) (813) (813) (813) (813) (813) (813) (813) 37 37 37 37 37 37 37 37 37 37 37 37 37 37 (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) 26 26 26 26 26 26 26 26 26 26 26 26 26 26 (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 20 (490) 20 (490) 23.5 (597) 23.5 (597) 28 (711) 28 (711) 28 (711) 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 20 (490) 20 (490) 20 (490) 20 (490) 23.5 (597) 23.5 (597) 28 (711) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-45 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 (620) (620) (620) (620) (610) (610) (610) (610) (610) (610) (610) (610) (610) (610) (610) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 20 (490) 20 (490) 20 (490) 20 (490) 20 (490) 23.5 (597) 28 (711) Main Disconnect Meter Module 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) (940) 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) (660) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 20 (490) 20 (490) 20 (490) 20 (490) 23.5 (597) 23.5 (597) 28 (711) Meter Center Cubicle Side Mount Panelboard BUSWAY SYSTEMS CU 225 400 600 800 1000 1200 1350 1600 2000 — 2500 3000 3200 4000 5000 N Frame Breaker (800-1200A) A B C 14 Molded Case Circuit Breaker Cubicles with Meter Tap Stack Provisions Dimensions, Inches (mm) L Frame Breaker (250-600A) M Frame Breaker (250-600A) Busway Ampere Rating Width W A B C A B C AL L-Rated 225 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 400 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 600 — 3.9 (99) 32 (813) 24 (620) 16 (406) 37 (940) 26 (660) 16 (406) 800 400 4.6 (117) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 1000 600 5.4 (137) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 1200 800 6.6 (168) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 1350 1000 7.6 (193) 32 (813) 24 (610) 16 (406) 37 (940) 26 (660) 16 (406) 1600 1200 8.7 (221) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 2000 1350,1600 10.9 (277) 32 (813) 24 (610) 20 (490) 37 (940) 26 (660) 20 (490) 2500 2000 13.7 (348) 32 (813) 24 (610) 23.5 (597) 37 (940) 26 (660) 23.5 (597) 3000 2500 15.8 (401) 32 (813) 24 (610) 23.5 (597) 37 (940) 26 (660) 23.5 (597) 3200 2000 17.3 (439) 32 (813) 24 (610) 23.5 (597) 37 (940) 26 (660) 28 (711) 4000 3000,3200 20.3 (516) 32 (813) 24 (610) 28 (711) 37 (940) 26 (660) 28 (711) 4000 3000,3200 20.3 (516) 32 (813) 24 (610) 28 (711) 37 (940) 26 (660) 28 (711) Busway Systems Installation and Application Information Installation In preparation for installation of your busway systems, it is important to familiarize yourself with the following installation publications: ▪ General Instructions For Handling, Installation, Operation and Maintenance of Busway Rated 600 volts or less (NEMA Standards Publication BU1) BUSWAY SYSTEMS 14 ▪ Storage, Installation and Maintainance Instructions for Sentron Busway (31-9918-01) These publications should be read through thoroughly and used as reference during installation to ensure proper installation procedures. All Selection equipment should be inspected upon delivery. If the busway is not installed immediately, it should be stored in a clean, dry location. Factory supplied record drawings as well as installation tools should be accessible in preparation for installation. UL 1479 Fire Rated Installations Sentron Busway has been tested in accordance with UL 1479 and offers a certified two hour fire rating for gypsum wallboard construction and a three hour fire rating for concrete slab or block penetrations. These ratings were achieved using standard busway installed with SpecSeal® sealant from Specified Technologies Inc. The SpecSeal® fire stop system provides superior Busway Order Entry Checklist Note: Submit one checklist for each busway run. Date Submitted: ____________ Purchase Order #: _______________________ Project Name: _____________________________ Submitted By: _____________________________ Sales Engineer: ____________________________ _____ Released _____ Hold for Release Run Designation: ___________________________ Busway Catalog #: __________________________ Service: _____ Phase _____ Wire _____ Volts _____ Amps Conductor: _____ Cu _____ Al _____ “M” Rated _____ “L” Rated Neutral: _____ None _____ 100% _____ 200% Ground: _____ Case _____ Internal _____ Isolated IP Rating _____ IP40 (Indoor) _____ IP55 (Splash Proof) _____ NEMA 3R (Outdoor) Shipping Instructions: _____ Ship complete _____ Ship partial Special Shipping Requirements:___________________________ Ship not before date: ____________ Drawing Requirements: _____ Approval drawings _____ Record drawings _____ # copies: _____ # copies: A) Engineering Information Check applicable information and be sure it is shown on accompanying drawing. performance at the industry’s lowest installed cost. Sentron is the first busway system to achieve a fire rating for gypsum wallboard construction. 11. _____ Riser Bus a) _____ Load side of bus plug (top or bottom) b) _____ Required distance from floor to top of panel/plugs c) _____ Meter Bank (center line of tap stack) d) _____ Barriers and/or floor supports 12. _____ Transformer Connections a) _____Standard XFMR Service Heads _____ 1-three phase _____ 3-single phase b) Special drawing required _____ Dimensions between phases _____ LV spade detail including drilling and thickness _____ Dimension of the LV spade from tank wall _____ Throat opening and hole pattern (if any) 13. _____ Utility Vault Connection _____ Drawing Attached Utility Type: _____ 14. End Cable Tap Box _____ Horizontal _____ Vertical _____ Standard Lugs _____ Special Lug Requirements No. _____ Size _____ per phase & neutral No. _____ Size _____ per ground Measuring Critical to the success of any busway installation is the layout and the accurate measuring of the busway. First and foremost: Select a route for your busway that will require the fewest fittings and the maxumum number of 10' (3.05m) sections. It is important that the busway system be designed to meet the requirements of the National Electric Code for Busway. There are a number of techniques that may be used to ensure an accurate measurement before purchasing and installing the busway. The following tools will be required during layout and masuring: ▪ 100' (30.48m) tape measure ▪ Meauring Stick ▪ Chalkline ▪ Plumb Bob ▪ Marker (A laser distance measuring device may be used to speed the measuring process). 15. _____ Busway Mounting position in reference to floor: 1. _____ Drawing Attached (Required) 2. _____ Estimate Sheets Attached (Required) 3. _____ Dimensions from walls, column lines, etc. 4. _____ Wall, floor, roof thickness and pitch Flatwise Edgewise 5. _____ Floor Elevations _____ Floor to floor _____ Floor to ceiling B) Specifications(Check or fill appropriate blanks) 6. _____ Wall Locations 2. _____ Exception to specifications a) Short circuit withstand _____ Ampere Symmetrical b) Voltage Drop Requirement _____ c) Temperature-rise requirement _____ d) Current density requirement _____ e) Special Paint: Provide paint chip _____ f) Other: ____________________________ 7. _____ Equipment Pads shown: Height _______ 8. ____ Existing busway to be extended a) _____ Phasing b) _____ Nameplate Informatio c) _____ Match to competitor: Call the factory 1. _____ Standard busway meets specifications Exception to electrical specifications: Call the factory. 9. ____ Secial Switchboard Connection: Provide Details 10. ____ Phase transpositions: Provide phasing on drawing. 14-46 Other Notes: ___________________________________________ ___________________________________________ ___________________________________________ Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Minimal Clearances Minimum clearances for installing feeder busway are shown. Additional clearance may be required for plug-in devices larger than 100A fusible and 250A circuit breaker. Busway Systems Siemens Sentron Busway Quick Reference General Siemens Sentron Busway Quick Reference Critical Dimensions: Busway that passes through a wall, ceiling or floor: ▪ centerline of a joint to the wall, ceiling or floor = 7 in. min. ▪ centerline of a joint (above a floor support) to a floor = 16 in. min. ▪ joints cannot be positioned inside a wall, ceiling or floor (joints must be accessible for maintenance) Feeder Busway clearances: ▪ from the top of the busway to a ceiling/floor/wall or other busway = 6 in. min. ▪ from the side of the busway to a ceiling/floor/wall or other busway = 4 in. min. Plug-in Busway clearances: ▪ plug-in busway clearances depend on the configuration of bus plugs (see bus plug clearance charts in the Sentron Selection and Application Guide) ▪ otherwise, clearances for feeder busway apply ▪ note orientation of the operating handle and provide clearance for access & operation Feeder Busway length: 14 BUSWAY SYSTEMS ▪ minimum length = 14.38 in. ▪ maximum length = 10 ft. Plug-in & Riser length: ▪ available only in 4, 6, 8 and 10 ft. lengths Flat Elbow section: ▪ maximum leg length = 4 ft. ▪ minimum leg length: Varies according to amperage and bus bar material Edge Elbow section: ▪ maximum length = 4 ft. ▪ minimum leg length = 10 in. Combination and Offset Elbows: ▪ maximum leg lengths = 4 ft. ▪ minimum leg length = 2.50 in. + (case size x .5) Critical Details: ▪ ▪ ▪ ▪ ▪ Busway DRAWINGs must include all relevant dimensions CENTERLINE dimensions are expected (please note any dimensions that are not center line dimensions) WALLs and FLOORs must be located (wall & floor thickness must be included) Locate the FRONT of all switchboards and provide the phasing of any existing boards (advise if any PADs are located under boards) When using RISER plug-in busway please note the desired direction of the load side of bus plugs (G, A, B, C, N from left to right will position the load side to the bottom and “UP is On” handle operation) TRANSFORMER THROAT connections require complete details Horizontal plug-in busway must be oriented with the A phase on top (bolt head on top) In-Line Disconnect CUBICLEs are engineered to order. The FRONT of the cubicle must be specified ▪ ▪ ▪ Outdoor Busway: ▪ Route busway to minimize outdoor busway run length ▪ Avoid installing busway near exhaust pipes that may generate steam or caustic vapors Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-47 Busway Power Distribution XJ-L™ Plug-In Busway Selection Busway Sections — Complete 10 Foot Plug-in Sections햲 Catalog Number List Price $ 5 Foot Plug-in Sections햲 Weight (lbs.) Catalog Number List Price $ Switchboard or Panelboard Stubs (flanged end) 2 Foot Plug-in Sections햲 Weight (lbs.) Catalog Number List Price $ Weight (lbs.) Catalog Number List Price $ 100 Ampere Busway — Copper Conductors햳 3-Phase, 3-Wire 600 Volts or Less XC1003 618.00 42 XC10035 412.00 20 XC10032 240.00 8 XC1003FE 709.00 XC1003G 햴 709.00 42 XC10035G 햴 474.00 21 XC10032G 햴 277.00 9 XC1003FEG 햴 798.00 XC1003IG 햵 722.00 44 XC10035IG 햵 499.00 20 XC10032IG 햵 281.00 8 XC1003FEIG 햵 785.00 XC1003GIG 햴햵 837.00 44 XC10035GIG 햴햵 578.00 21 XC10032GIG햴햵 325.00 9 XC1003FEGIG 햴햵 888.00 XC1004 722.00 45 XC10045 474.00 21 XC10042 270.00 9 XC1004FE 774.00 XC1004G 햴 774.00 46 XC10045G 햴 505.00 22 XC10042G 햴 309.00 10 XC1004FEG 햴 862.00 XC1004IG 햵 837.00 45 XC10045IG 햵 547.00 21 XC10042IG 햵 318.00 9 XC1004FEIG 햵 875.00 XC1004GIG 햴햵 976.00 46 XC10045GIG 햴햵 630.00 22 XC10042GIG햴햵 368.00 10 XC1004FEGIG 햴햵 951.00 BUSWAY SYSTEMS 14 3-Phase, 4-Wire 600 Volts or Less 225 Ampere Busway — Copper Conductors 3-Phase, 3-Wire 600 Volts or Less X2003 837.00 56 X20035 470.00 27 X20032 258.00 12 X2003FE X2003G 햶 951.00 58 X20035G 햶 499.00 28 X20032G 햶 298.00 13 X2003FEG 햶 1103.00 951.00 56 X20035IG 햵 544.00 27 X20032IG 햵 315.00 12 X2003FEIG 햵 1115.00 1115.00 58 X20035GIG 햵햶 671.00 28 X20032GIG 햵햶 371.00 13 X2003FEGIG 햵햶 1254.00 X2003IG 햵 X2003GIG 햵햶 3-Phase, 4-Wire 963.00 480 Volts or Less X2004 913.00 60 X20045 519.00 29 X20042 286.00 14 X2004FE 1052.00 X2004G 햶 932.00 62 X20045G 햶 565.00 30 X20042G 햶 326.00 15 X2004FEG 햶 1166.00 X2004IG 햵 1115.00 60 X20045IG 햵 594.00 29 X20042IG 햵 326.00 14 X2004FEIG 햵 1204.00 X2004GIG 햵햶 1204.00 62 X20045GIG 햵햶 722.00 30 X20042GIG 햵햶 401.00 15 X2004FEGIG 햵햶 1330.00 400 Ampere Busway — Copper Conductors 3-Phase, 3-Wire 600 Volts or Less X4003 1127.00 69 X40035 676.00 35 X40032 338.00 15 X4003FE 1299.00 X4003G 1296.00 75 X40035G 778.00 38 X40032G 389.00 16 X4003FEG 1487.00 X4003IG 1353.00 79 X40035IG 811.00 40 X40032IG 405.00 17 X4003FEIG 1505.00 X4003GIG 1466.00 84 X40035GIG 879.00 43 X40032GIG 439.00 18 X4003FEGIG 1693.00 3-Phase, 4-Wire 480 Volts or Less X4004 1240.00 79 X40045 744.00 40 X40042 372.00 17 X4004FE 1429.00 X4004G 1409.00 84 X40045G 845.00 43 X40042G 422.00 18 X4004FEG 1617.00 X4004IG 1466.00 89 X40045IG 879.00 45 X40042IG 439.00 19 X4004FEIG 1635.00 X4004GIG 1578.00 94 X40045GIG 947.00 48 X40042GIG 473.00 20 X4004FEGIG 1823.00 햲 Plug-in sections do not include outlet covers. Plug-in outlet covers are available as an option. Catalog number XOC. List price $12.00 each. 햳 100A XJ-L Aluminum sections are no longer available. However, 100A Copper sections are fully compatible with existing Aluminum busway. 햴 100% Internal Ground bus included. 햵 100% Isolated Ground bus included. 햶 60% Internal Ground bus included. Hangers: Two hangers are furnished No Charge with each 10' straight section. One hanger is furnished No Charge with each 2' and 5' straight section, and elbows. 14-48 Additional Hangers: Catalog Number XH2 — $34.50 each. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW Busway Power Distribution XJ-L™ Plug-In Busway Selection Busway Accessories — Complete Devices 90° Elbows Catalog Number End Tap Box End Closers List Price $ Catalog Number List Price $ Catalog Number Center Tap Box List Price $ Catalog Number List Price $ 100 Ampere Busway — Copper Conductors 3-Phase, 3-Wire 600 Volts or Less XC1003L 381.00 XE100 77.00 XC1003ETVB 858.00 — — XC1003LG 426.00 XE100 77.00 XC1003ETVBG 964.00 — — XC1003LIG 434.00 XE100 77.00 XC1003ETVBIG 950.00 — — XC1003LGIG 492.00 XE100 77.00 XC1003ETVBGIG 1072.00 — — XC1004L 430.00 XE100 77.00 XC1004ETVB 934.00 — — XC1004LG 449.00 XE100 77.00 XC1004ETVBG 1042.00 — — XC1004LIG 458.00 XE100 77.00 XC1004ETVBIG 1056.00 — — XC1004LGIG 516.00 XE100 77.00 XC1004ETVBGIG 1149.00 — — 3-Phase, 4-Wire 600 Volts or Less 3-Phase, 3-Wire 600 Volts or Less 949.00 XE200 86.00 X2003ETVB 1164.00 X2003M 1242.00 X2003LG 1000.00 XE200 86.00 X2003ETVBG 1333.00 X2003MG 1267.00 X2003LIG 1025.00 XE200 86.00 X2003ETVBIG 1349.00 X2003MIG 1267.00 X2003LGIG 1153.00 XE200 86.00 X2003ETVBGIG 1517.00 X2003MGIG 1292.00 3-Phase, 4-Wire X2004L BUSWAY SYSTEMS X2003L 14 225 Ampere Busway — Copper Conductors 480 Volts or Less 975.00 XE200 86.00 X2004ETVB 1271.00 X2004M 1254.00 X2004LG 1050.00 XE200 86.00 X2004ETVBG 1409.00 X2004MG 1254.00 X2004LIG 1216.00 XE200 86.00 X2004ETVBIG 1455.00 X2004MIG 1280.00 X2004LGIG 1368.00 XE200 86.00 X2004ETVBGIG 1609.00 X2004MGIG 1305.00 400 Ampere Busway — Copper Conductors 3-Phase, 3-Wire 600 Volts or Less X4003L 1281.00 XE400 89.00 X4003ETVB 1673.00 X4003M 1675.00 X4003LG 1351.00 XE400 89.00 X4003ETVBG 1916.00 X4003MG 1843.00 X4003LIG 1384.00 XE400 89.00 X4003ETVBIG 1938.00 X4003MIG 1934.00 X4003LGIG 1556.00 XE400 89.00 X4003ETVBGIG 2180.00 X4003MGIG 2178.00 3-Phase, 4-Wire 480 Volts or Less X4004L 1410.00 XE400 89.00 X4004ETVB 1841.00 X4004M 1843.00 X4004LG 1479.00 XE400 89.00 X4004ETVBG 2083.00 X4004MG 2027.00 X4004LIG 1513.00 XE400 89.00 X4004ETVBIG 2106.00 X4004MIG 2128.00 X4004LGIG 1684.00 XE400 89.00 X4004ETVBGIG 2348.00 X4004MGIG 2396.00 Plug-In Tap Boxes or Feed-Ins Catalog Number List Price $ Catalog Number 3-Phase, 3-Wire Elbows: Catalog Numbers as listed above are not complete. A 1, 2, 3 or 4 suffix denoting configuration is required. Example: Catalog Number X1003L2 is an edgewise right hand elbow. Number Identification (1)=Flatwise Right Hand, (2)=Edgewise Right Hand, (3)=Flatwise Left Hand, (4)=Edgewise Left Hand. Flatwise and Edgewise refer to busway casing or housing for XJ-L style busway. 100A XJ-L Aluminum sections are no longer available. However, 100A Copper sections are fully compatible with existing Aluminum busway. 100% Internal Ground bus included. 100% Isolated Ground bus included. 60% Internal Ground bus included. Isolated ground kit for tap box W68113 — $46.00 each. Discount Schedule BUSW Center Tap Boxes are built on to a 2' straight section. Catalog number X2004MG — Rated 400 Amps. Center tap box for 100 amp use 200 AMP Plug-In Tap Box. Must use X2003MIG. Must use X2003MGIG. Must use X2004MIG. Must use X2004MGIG. Note: Wall and Floor Flanges: a two piece 14 gauge steel collar which fits around busway housing. Flanges can be field assembled on busway prior to or after busway installed. Wall or Floor Flange Catalog Number — WF1 for X100 and WF2 for X200 — $81.00 each. Packaged 5 per carton. List Price $ 600 Volts or Less X103PB 242.00 X2003PB 616.00 X103PBG 301.00 X2003PBG 823.00 X103PBIG 305.00 X103PBGIG 358.00 3-Phase, 4-Wire — — 480 Volts or Less X104PB 346.00 X2004PB 646.00 X104PBG 401.00 X2004PBG 925.00 X104PBIG 411.00 — X104PBGIG 464.00 — Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-49 Busway Power Distribution BD® Plug-In (225 — 1600 Ampere) Selection 225–1600 Amperes Ampere Rating Plug In 햲 10'– 0" Straight Length Catalog Number 10'– 0" Straight Length Ground Bus Adder Suffix GK 90° Elbow Prefix Building Expansion Fitting SwitchBoard Connection 햷 Prefix List Price $ Catalog Number Case Dimensions (inches) Shipping Weight Lb./Ft. 햳 햴 햵햶 List Price $ List Price Per Foot $ Catalog Number 41⁄16 41⁄16 41⁄16 61⁄16 61⁄16 121⁄8 121⁄8 09 121⁄2 131⁄2 181⁄2 22 28 29 1584.00 2395.00 3067.00 4486.00 4854.00 7338.00 7819.00 66. 66. 69. 69. 69. 98. 140. LDP302 LDP304 LDP306 LDP308 LDP310 LDP313 LDP316 1520.00 1761.00 1963.00 2394.00 2584.00 3573.00 3712.00 FEP302 FEP304 FEP306 FEP308 FEP310 FEP313 FEP316 1052.00 1216.00 1635.00 1977.00 2230.00 2940.00 3004.00 EJP302 EJP304 EJP306 EJP308 EJP310 EJP313 EJP316 12 141⁄2 151⁄2 28 2053.00 3459.00 3929.00 5729.00 66. 66. 69. 69. LDP4024 LDP4044 LDP4064 LDP4084 1875.00 2293.00 2432.00 3167.00 FEP4024 FEP4044 FEP4064 FEP4084 1191.00 1483.00 1837.00 2294.00 EJP4024 EJP4044 EJP4064 EJP4084 4081.00 5677.00 6451.00 8694.00 32 6704.00 69. LDP4104 3459.00 FEP4104 2420.00 EJP4104 10139.00 List Price $ List Price $ Copper 3-Phase, 3-Wire 225 400 600 800 1000 1350 1600 BDP302 BDP304 BDP306 BDP308 BDP310 BDP313 BDP316 600V or Less x x x x x x x 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 BUSWAY SYSTEMS 14 3-Phase, 4-Wire — Full Capacity Neutral 225 400 600 800 1000 BDP4024 BDP4044 BDP4064 BDP4084 BDP4104 41⁄16 41⁄16 41⁄16 81⁄8 81⁄8 x x x x 87⁄8 87⁄8 87⁄8 87⁄8 x 87⁄8 480V or Less “M” Rating / Standard Rating Conversion Table Aluminum to Copper Cross Reference Plug In 햲 10'– 0" Straight Length Catalog Number Ampere Rating Case Dimensions (inches) Aluminum 225 400 600 800 1000 1200 Ampere Rating ABD302 ABD304 ABD306 ABD308 ABD310 ABD312 1000/A Square Inch “M” Rating 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 4000 Case Dimensions (inches) 3-Phase, 3-Wire 41⁄16 41⁄16 61⁄16 61⁄16 121⁄8 121⁄8 x x x x x x 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 225 400 600 800 1000 1350 1600 3-Phase, 4-Wire — Full Capacity Neutral 225 400 600 800 1000 1200 Plug In 햲 10'– 0" Straight Length Catalog Number Copper 3-Phase, 3-Wire ABD4024 ABD4044 ABD4064 ABD4084 ABD4104 ABD4124 41⁄16 41⁄16 61⁄16 81⁄8 121⁄8 121⁄8 x x x x x x 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 For inches / millimeters conversion, see Application Data Section. BDP302 BDP304 BDP306 BDP308 BDP310 BDP313 BDP316 41⁄16 41⁄16 41⁄16 61⁄16 61⁄16 121⁄8 121⁄8 x x x x x x x 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 Standard 55°C Rating BDP — 0600 0800 0800 1000 — 1350 1600 — — — — 3-Phase, 4-Wire — Full Capacity Neutral 225 400 600 800 1000 BDP4024 BDP4044 BDP4064 BDP4084 BDP4104 41⁄16 41⁄16 41⁄16 81⁄8 81⁄8 x x x x x 87⁄8 87⁄8 87⁄8 87⁄8 87⁄8 햶 햵 Suffix Description 햲 Consult -1 Right Flatwise 햳 List -2 Right Edgewise -3 Left Flatwise -4 Left Edgewise local sales office for five foot length. prices are for standard construction, for higher short circuit ratings add an “H” after the “D” or “P” (ABDH302 or BDPH302) and add 20% to the list price. Consult sales office for ratings. 햴 “GK” is an internal ground bus. For any other ground configuration, consult local sales office. List price is per foot. Please use following footage for fittings: Elbow - 3' SWB - 1' End Cable Tap Box - 1' Center Cable Tap Box - 10' Building Expansion - 10' 14-50 3333.00 4372.00 5171.00 7299.00 7896.00 10341.00 11343.00 Appropriate suffix must be added to Elbow Catalog Number to order. 햷 Switchboard Right Edgewise Elbow (-2) Left Edgewise Elbow (-4) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog stub includes flange to cover cutout in top of indoor switchboard and 6" of bus inside switchboard. Connecting hardware supplied by switchboard manufacturer. Discount Schedule BUSW Busway Power Distribution BD® Plug-In (225 — 1600 Ampere) Selection 225–1600 Amperes Cable Tap Box End Catalog Number Hangers End Closure Center List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ ETB302 1927.00 CTB302 2813.00 ECP6 156.00 BDH10 63.00 ETB304 2319.00 CTB304 3612.00 ECP6 ETB306 3409.00 CTB306 4614.00 ECP6 BDH10 63.00 ETB308 3447.00 CTB308 6058.00 ECP10 ETB310 3472.00 CTB310 6388.00 ECP10 BDH10 63.00 ETB313 3497.00 CTB313 9391.00 ECA10 ETB316 3524.00 CTB316 9872.00 ECA10 163.00 BDH12 65.00 156.00 BDH10 63.00 156.00 BDH10 63.00 Copper 3-Phase, 3-Wire 600V or Less 156.00 158.00 3-Phase, 4-Wire — Full Capacity Neutral 480V or Less CTB4024 3282.00 ECP6 ETB4044 2598.00 CTB4044 4677.00 ECP6 ETB4064 3802.00 CTB4064 5462.00 ECP6 ETB4084 3992.00 CTB4084 7274.00 ECA8 ETB4104 4042.00 CTB4104 8238.00 ECA8 164.00 BDH12 65.00 BDH12 65.00 Rod-Hanger Adapter (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UJ100 Includes busway stub. Total length added to run is 2' for 225A and 400A aluminum or 225A–600A copper; 3' for all others. Box is designed to connect to offset bus-bar ends. When it is to be connected to straight bus-bar ends, adapter will be furnished upon request. Must be factory-assembled to busway. Complete device includes 10' busway. Discount Schedule BUSW 12.70 each Two hangers included free of charge with each busway section, elbow, tee and cross. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-51 BUSWAY SYSTEMS 2155.00 14 ETB4024 Busway Power Distribution XL-U® Aluminum (225–5000 Ampere) Selection 225–5000 Amperes / 600 Volts or Less Non-Ventilated 225–600 Amperes List Price Per Foot $ Busway Catalog Number Ampere Rating Accessory Charge $ Basic Catalog Number Case Shipping Feeder Plug-In Dimensions Weight Busway Busway (inches) Lb./Ft. Suffix F Suffix P Ground Bus Adder Suffix G UH302AB UH304AB UH306AB 41⁄2 x 10 41⁄2 x 10 51⁄2 x 10 8 9 10 134. 167. 208. 134. 167. 208. 47. 47. 52. 1076. 1280. 1533. 41⁄2 x 10 41⁄2 x 10 51⁄2 x 10 8 9 10 157. 195. 264. 157. 195. 264. 45. 45. 48. 1201. 1416. 1487. 90° Elbow Suffix L Tee Suffix T Cross Suffix X SwitchBoard Connection Suffix S TransTrans- former former Tap Throat 1-3 Phase Transformer Tap 3-1 Phase Roof Flange 747. 747. 747. — — — — 844. 844. 844. — — — — 3-Pole 225 400 600 4-Pole Full Neutral 225 400 600 UH502AB UH504AB UH506AB BUSWAY SYSTEMS 14 Note: For non-ventilated 225-600A busway with insulated bus bars add 15%. Ventilated 800–5000 Amperes With Ground Bus List Price Per Foot $ Busway Sections Complete Ampere Rating Edgewise Flatwise Basic Catalog Number Case Shipping Feeder Dimensions Weight Busway (inches) Lb./Ft. Suffix F Plug-In Busway Suffix P Accessory Charge $ Outdoor Feeder 90° Suffix Elbow W Suffix L Switch Board Connec- TransTee Cross tion former Suffix T Suffix X Suffix S Throat Transformer Tap 1-3 Phase Transformer Tap Roof 3-1 Phase Flange 3-Pole 800 1000 800 800 UH308AV UH310AV 41⁄2 x 10 41⁄2 x 10 10 11 297. 335. 311. 349. 357. 403. 1200 1350 1000 1200 UH312AV UH313AV 51⁄2 x 10 51⁄2 x 10 12 13 459. 525. 472. 540. 549. 630. 1533. 1600 2000 1350 1600 UH316AV UH320AV 71⁄2 x 10 71⁄2 x 10 16 19 646. 773. 659. 785. 773. 924. 1533. 2500 2000 UH325AV 91⁄2 x 10 23 950. 962. 1141. 1533. 1938. 2268. 1065. 9048. 1951. 4879. 3510. 3000 3000 UH330AV 71⁄2 x 205⁄8 32 1076. 1090. 1292. 1938. 2281. 2395. 1356. 11406. 2458. 6159. 4423. 4000 5000 3500 4000 UH340AV UH350AV 91⁄2 x 205⁄8 91⁄2 x 205⁄8 41 45 1482. 1964. 1495. 1976. 1774. 2357. 1938. 1938. 2281. 2281. 2395. 2395. 1356. 1356. 11406. 11406. 2458. 2458. 6159. 6159. 4423. 2585. 1128. 1558. 785. 785. 6679. 6679. 1444. 1444. 3599. 3599. 1938. 2268. 1065. 1065. 9048. 9048. 1951. 1951. 4879. 4879. 1938. 2268. 1065. 1065. 9048. 9048. 1951. 1951. 4879. 4879. 1368. 2585. 3510. 4-Pole Full Neutral 800 1000 800 800 UH508AV UH510AV 41⁄2 x 10 41⁄2 x 10 11 12 351. 440. 365. 453. 421. 527. 1648. 1648. 1648. 1648. 1964. 1964. 962. 962. 6944. 6944. 1533. 1533. 3662. 3662. 1200 1350 1000 1200 UH512AV UH513AV 5 ⁄2 x 10 51⁄2 x 10 14 15 552. 634. 566. 646. 659. 760. 2256. 2256. 2256. 2698. 1318. 1318. 7489. 7489. 2155. 2155. 4638. 4638. 1600 2000 1350 1600 UH516AV UH520AV 71⁄2 x 10 71⁄2 x 10 18 21 760. 950. 773. 962. 899. 1141. 2256. 2256. 2256. 2698. 2698. 1318. 1318. 7489. 8453. 2155. 2559. 4638. 5589. 2500 2000 UH525AV 91⁄2 x 10 26 1153. 1166. 1381. 2256. 2256. 2698. 1318. 9580. 3523. 7693. 3510. 3000 3000 UH530AV 71⁄2 x 205⁄8 35 1343. 1356. 1610. 2698. 2698. 3218. 1583. 9580. 4169. 7693. 4423. 4000 5000 3500 4000 UH540AV UH550AV 91⁄2 x 205⁄8 91⁄2 x 205⁄8 47 52 1799. 2737. 1812. 2750. 2166. 3282. 2698. 2698. 3218. 1583. 13712. 4169. 9618. 4423. 1 For inches / millimeters conversion, see Application Data Section. Note: To form complete catalog number, use basic catalog number and substitute suffix of required item. Example: Basic busway Catalog Number U316AV— accessory switchboard stub with ground bus U316AVSG. To price complete device, add the following feeder busway footage to the labor charges shown: XL-U Elbow 2' XLU-EXP Section 4' XL-U Tee 3' XL-U SWBD Stub 1' XL-U Cross 4' XL-U Reducer 4' List prices are for standard construction for higher short circuit rating add an “HH” after the “U” (UHH302ABP) and add 45% to the list price. Consult sales office for available ratings. 14-52 3510. For elbows other than 90°, accessory charge is doubled. stub includes flange to cover cutout in top of indoor switchboard and 8" of bus inside switchboard. Connecting hardware supplied by switchboard manufacturer. Ventilated XL-U busway has two ratings; see above for edgewise or flatwise mounting. XL-U also comes in nonventilated housing; consult local sales office. Transformer throat connection includes gasketed box sized to match throat plus flexible straps and bolts. No Busway footage is included. For connection to transformers not manufactured by Siemens, consult factory. Switchboard Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW Busway Power Distribution XL-U® Aluminum (225–5000 Ampere) Selection 225–5000 Amperes / 600 Volts or Less Non-Ventilated 225– 600 Amperes Accessory Charge $ Non Ampere Fusible Fusible Rating Reducer Reducer Complete Device Price $ Expansion Tap Box Section End Center Suffix J Suffix B Suffix M Wall Flange 1888. 2142. 2332. 1330. 1989. 2839. 1292. 1292. 1292. UF145 UF145 UF145 226.00 UFS145 226.00 UFS145 226.00 UFS145 422.00 UE145 422.00 UE145 422.00 UE155 — 422. 293.00 422. 293.00 422. 849. 849. 849. UH145 UH145 UH155 — 65.00 65.00 1888. 2142. 2332. 1545. 1723. 1825. 1507. 1507. 1507. UF145 UF145 UF145 226.00 UFS145 226.00 UFS145 226.00 UFS145 422.00 UE145 422.00 UE145 422.00 UE155 293.00 422. 293.00 422. 293.00 422. 1051. 1051. 1051. UH145 UH145 UH155 65.00 65.00 65.00 Floor Support Hangers End Closure Catalog List Catalog List Catalog List Draft Weather Catalog List Number Price $ Number Price $ Number Price $ Barrier Stop Number Price $ 3-Pole 225 400 600 — 747. 785. — 3054. 3472. 4-Pole Full Neutral 225 400 600 — 747. 785. — 3054. 3472. Ventilated 800–5000 Amperes with Ground Bus 800 1000 1200 1350 1600 2000 2500 3000 4000 5000 1051. 1051. 1419. 1419. 1419. 1419. 1419. 1787. 1787. 1787. 4410. 4410. 5957. 5957. 5957. 5957. 5957. 7514. 7514. 7514. 3142. 3142. 4257. 4257. 4257. 4257. 4257. 5374. 5374. 5374. 3054. 3054. 4131. 4131. 4131. 4131. 4473. 4613. 4854. 4854. 1356. 1356. 1761. 1761. 1761. 1761. 1761. 5969. 6235. 6235. UF145 UF145 UF155 UF155 UF175 UF175 UF195 UF275 UF295 UF295 226.00 226.00 226.00 226.00 323.00 323.00 323.00 1103.00 1103.00 1103.00 UFS145 UFS145 UFS145 UFS145 UFS179 UFS179 UFS179 UFS279 UFS279 UFS279 422.00 422.00 422.00 422.00 506.00 506.00 506.00 709.00 709.00 709.00 UE145 UE145 UE155 UE155 UE175 UE175 UE175 UE275 UE295 UE295 293.00 293.00 293.00 293.00 715.00 715.00 715.00 1147.00 1147.00 1147.00 422. 422. 422. 422. 506. 506. 506. 709. 709. 709. 899. 899. 899. 899. 1305. 1305. 1305. 1711. 1711. 1711. UH145 UH145 UH155 UH155 UH175 UH175 UH195 UH275 UH295 UH295 65.00 65.00 65.00 65.00 80.00 80.00 80.00 96.00 96.00 96.00 3611. 3611. 4892. 4892. 4892. 4892. 4892. 5424. 6184. 6184. 3472. 3472. 4537. 4537. 4537. 4537. 5424. 5766. 6045. 6045. 1610. 1610. 2128. 2128. 2128. 2128. 2128. 7350. 7629. 7629. UF145 UF145 UF155 UF155 UF175 UF175 UF195 UF275 UF295 UF295 226.00 226.00 226.00 226.00 323.00 323.00 323.00 1103.00 1103.00 1103.00 UFS145 UFS145 UFS145 UFS145 UFS179 UFS179 UFS179 UFS279 UFS279 UFS279 422.00 422.00 422.00 422.00 506.00 506.00 506.00 709.00 709.00 709.00 UE145 UE145 UE155 UE155 UE175 UE175 UE195 UE275 UE295 UE295 293.00 293.00 293.00 293.00 715.00 715.00 715.00 1147.00 1147.00 1147.00 422. 422. 422. 422. 506. 506. 506. 709. 709. 709. 1153. 1153. 1153. 1153. 1673. 1673. 1673. 2052. 2052. 2052. UH145 UH145 UH155 UH155 UH175 UH175 UH195 UH275 UH295 UH295 65.00 65.00 65.00 65.00 80.00 80.00 80.00 96.00 96.00 96.00 4-Pole Full Neutral 800 1000 1200 1350 1600 2000 2500 3000 4000 5000 1204. 1204. 1635. 1635. 1635. 1635. 2052. 2052. 2052. 2052. 5069. 5069. 6843. 6843. 6843. 6843. 6843. 8643. 8643. 8643. For inches / millimeters conversion, see Application Data Section. For reducer, consult page 14-2 (J). On fusible reducers no fuses are supplied. boxes furnished with standard screw-type mechanical lugs. For compression lugs add 30% to list price. Floor and ceiling flanges are ordered by description. Price the same as wall flanges. rod-hanger adapter UJ100 see page 14-51. For Tap Discount Schedule BUSW Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-53 BUSWAY SYSTEMS 3-Pole 14 Ampere Accessory Charge $ Complete Device Price $ Rating Tap Box Wall Flange Floor Support End Closure Hangers Non Expansion Edge Fusible Fusible Section End Center Catalog List Catalog List Catalog List Draft Weather Catalog List wise Reducer Reducer Suffix J Suffix B Suffix M Number Price $ Number Price $ Number Price $ Barrier Stop Number Price $ Busway Power Distribution XL-U ® Copper (225–6500 Amperes) Selection 225–6500 Amperes / 600 Volts or Less Non-Ventilated 225–600 Amperes List Price Per Foot $ Busway Catalog Number Accessory Charge $ Ampere Rating Basic Catalog Number Case Shipping Feeder Dimensions Weight Busway (inches) Lb./Ft. Suffix F Plug-In Busway Suffix P Ground Bus Adder Suffix G 90° Elbow Suffix L Tee Suffix T Cross Suffix X SwitchBoard Connection Suffix S TransTrans- former former Tap Throat 1-3 Phase Transformer Tap 3-1 Phase Roof Flange 3-Pole 225 400 600 UH302CB UH304CB 41⁄2 x 10 UH306CB 8 12 13 166. 248. 327. 166. 248. 327. 72. 72. 74. — 1076. — — 1280. — — 1533. — 747. 899. 1051. — — — — 9 13 15 227. 370. 424. 227. 370. 424. 72. 72. 74. — 1280. — — 1533. — — 1787. — 899. 1076. 1254. — — — — 4-Pole Full Neutral 225 400 600 UH502CB UH504CB 41⁄2 x 10 UH506CB BUSWAY SYSTEMS 14 Ventilated 800–6500 Amperes With Ground Bus List Price Per Foot $ Busway Sections Complete Ampere Rating Edgewise Flatwise Accessory Charge $ Basic Catalog Number Case Shipping Feeder Dimensions Weight Busway (inches) Lb./Ft. Suffix F Plug-In Busway Suffix P Outdoor Feeder 90° Suffix Elbow W Suffix L Switch Board Connec- TransTee Cross tion former Suffix T Suffix X Suffix S Throat Transformer Tap 1-3 Phase Transformer Tap Roof 3-1 Phase Flange 3-Pole 800 1000 1200 1350 1600 2000 2500 3000 4000 5000 800 1000 1000 1200 1350 1600 2000 2500 4000 4500 UH308CV UH310CV UH312CV UH313CV UH316CV UH320CV UH325CV UH330CV UH340CV UH350CV 41⁄2 41⁄2 41⁄2 41⁄2 51⁄2 51⁄2 71⁄2 91⁄2 71⁄2 71⁄2 x x x x x x x x x x 10 10 10 10 10 10 10 10 205⁄8 205⁄8 12 15 16 19 23 26 34 41 57 70 490. 510. 684. 798. 899. 1153. 1457. 1596. 2294. 2763. 504. 524. 697. 811. 912. 1166. 1482. 1610. 2306. 2775. 587. 612. 811. 962. 1076. 1381. 1761. 1913. 2750. 3320. 1128. 1128. 1128. 1128. 1533. 1533. 1533. 1533. 1938. 1938. 1368. 1368. 1368. 1368. 1850. 1850. 1850. 1850. 2332. 2332. 1558. 1558. 1558. 1558. 2117. 2117. 2117. 2117. 2662. 2662. 1166. 1166. 1166. 1166. 1571. 1571. 1571. 1571. 1976. 1976. 6679. 6679. 6679. 6679. 9048. 9048. 9048. 9048. 11406. 11406. 1444. 1444. 1444. 1444. 1951. 1951. 1951. 1951. 2458. 2458. 3599. 3599. 3599. 3599. 4879. 4879. 4879. 4879. 6159. 6159. 2585. 2585. 2585. 2585. 3510. 3510. 3510. 3510. 4423. 4423. 6000 6500 5000 5500 UH360CV UH365CV 91⁄2 x 205⁄8 91⁄2 x 205⁄8 85 98 3320. 3485. 3346. 3497. 3992. 4182. 1938. 1938. 2332. 2332. 2662. 2662. 1976. 1976. 11406. 11406. 2458. 2458. 6159. 6159. 4423. 4423. 14 18 19 23 28 30 42 61 70 86 105 122 646. 735. 899. 1013. 1229. 1482. 1799. 2319. 2990. 3624. 4436. 4790. 659. 747. 912. 1038. 1242. 1495. 1812. 2332. 3003. 3637. 4448. 4802. 1153. 887. 1076. 1229. 1469. 1774. 2166. 2788. 3586. 4347. 5322. 5740. 1381. 1381. 1381. 1381. 1888. 1888. 1888. 1888. 2268. 2268. 2268. 2268. 1673. 1673. 1673. 1673. 2281. 2281. 2281. 2281. 2737. 2737. 2737. 2737. 1901. 1901. 1901. 1901. 2559. 2559. 2559. 2559. 3041. 3041. 3041. 3041. 1419. 1419. 1419. 1419. 1938. 1938. 1938. 1938. 2319. 2319. 2319. 2319. 6944. 6944. 6944. 6944. 7489. 7489. 7489. 7489. 13712. 13712. 13712. 13712. 1520. 1520. 1520. 1520. 2155. 2155. 2155. 2155. 3523. 3523. 4169. 4169. 3662. 3662. 3662. 3662. 4638. 4638. 4638. 4638. 7693. 7693. 9618. 9618. 2585. 2585. 2585. 2585. 3510. 3510. 3510. 3510. 4423. 4423. 4423. 4423. 4-Pole Full Neutral 800 1000 1200 1350 1600 2000 2500 3000 4000 5000 6000 6500 800 1000 1000 1200 1350 1600 2000 2500 4000 4500 5000 5500 UH508CV UH510CV UH512CV UH513CV UH516CV UH520CV UH525CV UH530CV UH540CV UH550CV UH560CV UH565CV 41⁄2 41⁄2 41⁄2 41⁄2 51⁄2 51⁄2 71⁄2 71⁄2 71⁄2 71⁄2 91⁄2 91⁄2 x x x x x x x x x x x x 10 10 10 10 10 10 10 10 205⁄8 205⁄8 205⁄8 205⁄8 “M” Rating / Standard Rating Conversion Table 1000/A Square Inch “M” Rating 225 400 600 800 1000 1200 1350 1600 2000 2500 3000 4000 14-54 Standard 55°C Rating XL-U — — 800 1200 1350 1600 2000 2500 2500 3000 4000 5000 Note: To form complete catalog number, use basic catalog number and substitute suffix of required item. Example: Basic busway Catalog Number U316CV— accessory switchboard stub with ground bus U316CVSG. To price complete device, add the following feeder busway footage to the labor charges shown: XL-U Elbow 2' XLU-EXP Section 4' XL-U Tee 3' XL-U SWBD Stub 1' XL-U Cross 4' XL-U Reducer 4' List prices are for standard construction for higher short circuit rating add an “HH” after the “U” (UHH302CBP and add 45% to the list price. Consult sales office for available ratings. For elbows other than 90°, accessory charge is doubled. Switchboard stub includes flange to cover cutout in top of indoor switchboard and 8'' of bus inside switchboard. Connecting hardware supplied by switchboard manufacturer. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Ventilated XL-U busway has two ratings; see above for edgewise or flatwise mounting. XL-U also comes in nonventilated housing; consult local sales office. Transformer throat connection includes gasketed box sized to match throat plus flexible straps and bolts. No Busway footage is included. For connection to transformers not manufactured by Siemens, consult factory. Ventilated busway has aluminum ground bus as standard. For copper ground bus multiply footage price by 1.05. Discount Schedule BUSW Busway Systems XL-U® Copper (225–6500 Amperes) Selection 225–6500 Amperes / 600 Volts or Less Non-Ventilated 225– 600 Amperes Accessory Charge $ Non Fusible Ampere Fusible Rating Reducer Reducer Complete Device Price $ Expansion Tap Box Section End Center Suffix J Suffix B Suffix M Wall Flange Floor Support Hangers End Closure Catalog List Catalog List Catalog List Draft Weather Catalog List Number Price $ Number Price $ Number Price $ Barrier Stop Number Price $ 3-Pole 225 400 600 — 735. 735. — 3003. 3003. 1850. 2103. 2103. 1381. 2078. 2965. 1267. 1267. 1267. UF145 UF145 UF145 226.00 UFS145 226.00 UFS145 226.00 UFS145 422.00 UE145 422.00 UE145 422.00 UE145 293.00 293.00 293.00 414. 414. 414. 823. 823. 823. UH145 UH145 UH145 65.00 65.00 65.00 2205. 2509. 2509. 1698. 1863. 2002. 1482. 1482. 1482. UF145 UF145 UF145 226.00 UFS145 226.00 UFS145 226.00 UFS145 422.00 UE145 422.00 UE145 422.00 UE145 293.00 293.00 293.00 414. 414. 414. 1038. 1038. 1038. UH145 UH145 UH145 65.00 65.00 65.00 4-Pole Full Neutral 225 400 600 — 874. 874. — 3573. 3573. Ventilated 800–6500 Amperes with Ground Bus 800 1000 1200 1350 1600 2000 2500 3000 4000 5000 6000 6500 1026. 1026. 1026. 1026. 1394. 1394. 1394. 1394. 1761. 1761. 1761. 1761. 4322. 4322. 4322. 4322. 5854. 5854. 5854. 5854. 7388. 7388. 7388. 7388. 3092. 3092. 3092. 3092. 4182. 4182. 4182. 4182. 5271. 5271. 5271. 5271. 3180. 3180. 4245. 4245. 4423. 4423. 4423. 4423. 4701. 4701. 4701. 4701. 1330. 1330. 1330. 1330. 1723. 1723. 1723. 1723. 6679. 6679. 6679. 6679. UF145 UF145 UF145 UF145 UF155 UF155 UF175 UF195 UF275 UF275 UF295 UF295 226.00 226.00 226.00 226.00 226.00 226.00 323.00 323.00 1103.00 1103.00 1103.00 1103.00 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS179 UFS179 UFS279 UFS275 UFS279 UFS279 422.00 422.00 422.00 422.00 422.00 422.00 506.00 506.00 709.00 709.00 709.00 709.00 UE145 UE145 UE145 UE145 UE155 UE155 UE175 UE195 UE275 UE275 UE295 UE295 293.00 293.00 293.00 293.00 293.00 293.00 715.00 715.00 1147.00 1147.00 1147.00 1147.00 414. 414. 414. 414. 414. 414. 496. 496. 697. 697. 697. 697. 887. 887. 887. 887. 887. 887. 1280. 1280. 1685. 1685. 1685. 1685. UH145 UH145 UH145 UH145 UH155 UH155 UH175 UH195 UH275 UH275 UH295 UH295 65.00 65.00 65.00 65.00 65.00 65.00 80.00 80.00 96.00 96.00 96.00 96.00 800 1000 1200 1350 1600 2000 2500 3000 4000 5000 6000 6500 1178. 1178. 1178. 1178. 1596. 1596. 1596. 1596. 2027. 2027. 2027. 2027. 4968. 4968. 4968. 4968. 6729. 6729. 6729. 6729. 8491. 8491. 8491. 8491. 3548. 3548. 3548. 3548. 4815. 4815. 4815. 4815. 6058. 6058. 6058. 6058. 3662. 3662. 3662. 3662. 5082. 5082. 5082. 5082. 7034. 7034. 7034. 7034. 1571. 1571. 1571. 1571. 2090. 2090. 2090. 2090. 9353. 9353. 9353. 9353. UF145 UF145 UF145 UF145 UF155 UF155 UF175 UF195 UF275 UF275 UF295 UF295 226.00 226.00 226.00 226.00 226.00 226.00 226.00 226.00 1103.00 1103.00 1103.00 1103.00 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS179 UFS179 UFS279 UFS279 UFS279 UFS279 422.00 422.00 422.00 422.00 422.00 422.00 506.00 506.00 709.00 709.00 709.00 709.00 UE145 UE145 UE145 UE145 UE155 UE155 UE175 UE195 UE275 UE275 UE295 UE295 293.00 414. 293.00 414. 293.00 414. 293.00 414. 293.00 414. 293.00 414. 715.00 496. 715.00 496. 1147.00 697. 1147.00 697. 1147.00 1026. 1147.00 1026. 1128. 1128. 1128. 1128. 1128. 1128. 1648. 1648. 2014. 2014. 2014. 2014. UH145 UH145 UH145 UH145 UH155 UH155 UH175 UH195 UH275 UH275 UH295 UH295 65.00 65.00 65.00 65.00 65.00 65.00 80.00 80.00 96.00 96.00 96.00 96.00 For inches / millimeters conversion, see Application Data Section. For reducer, consult page 14-2 (J). On fusible reducers no fuses are supplied. boxes furnished with standard screw-type mechanical lugs. For compression lugs add 30% to list price. Floor and ceiling flanges are ordered by description. Price the same as wall flanges. For rod-hanger adapter UJ100 see page 14-51. Tap Discount Schedule BUSW Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-55 BUSWAY SYSTEMS 3-Pole 14 Ampere Accessory Charge $ Complete Device Price $ Rating Wall Flange Floor Support End Closure Hangers EdgeNon Expansion Tap Box wise Fusible Fusible Section End Center Catalog List Catalog List Catalog List Draft Weather Catalog List Reducer Reducer Suffix J Suffix B Suffix M Number Price $ Number Price $ Number Price $ Barrier Stop Number Price $ Busway Power Distribution XJ-L™ Plug-In Units Selection XQ Circuit Breaker Enclosures Front Operable Enclosures Only Breaker Type AC Volts QP and BQ 120/240 3-Phase, 3-Wire 3-Phase, 4-Wire Breaker Ampere Rating Catalog Number List Price $ Catalog Number List Price $ 15–50 15–50 XQ35 XQ35R 184.00 264.00 XQ45 XQ45R 198.00 288.00 Circuit Breaker Bus Plugs — Front Operable Operable Through Cover 14 Circuit Breaker Enclosure XQ45 3-Phase, 3-Wire 3-Phase, 4-Wire Enclosure Only Enclosure Only Breaker Breaker AC Ampere Catalog Type Volts Rating Number ED2 240 15–50 60–100 ED4 480 15–50 60–100 List Catalog Price $ Number List Catalog Price $ Number List Catalog Price $ Number List Price $ XEC3100 408.00 XEC3100IG 461.00 XEC4100 517.00 XEC4100IG 570.00 BUSWAY SYSTEMS Circuit Breaker Plugs — Floor Operable Breaker AC Type Volts ED2 240 ED4 480 ED6 600 3-Phase, 3-Wire 3-Phase, 4-Wire Breaker Enclosure Only Enclosure Only Ampere Rating Catalog Number List Price $ Catalog Number List Price $ XLEC3100 649.00 XLEC4100 794.00 15–50 60–100 15–50 60–100 15–50 60–100 Fusible Vacu-Break Switch Plugs Floor Operable Circuit Breaker Bus Plug (Receptacles and covers supplied by installer) XQ45R 3-Pole Volts 240 600 Ampere Rating Catalog Number Catalog Number List Price $ XLVB321 706.00 XLVB421N 880.00 60 XLVB322 775.00 XLVB422N 902.00 100 XLVB323 1181.00 XLVB423N 1320.00 30 XLVB351 775.00 XLVB451N 915.00 60 XLVB352 845.00 XLVB452N 949.00 100 XLVB353 1203.00 XLVB453N 1355.00 XEQH 14-56 List Price $ 30 For inches / millimeters conversion, see Application Data Section. Circuit Breaker Bus Plug Front-operable XEC4100 4-Pole floor-operating handle with “ON-OFF” labels, $44.50 each. Designed for 2 or 3-pole breakers only. Standard package 10 per carton. Ground kit for bonded ground Catalog Number W62890. List price $56.00. Ground kit for isolated ground Catalog Number W68101. List price $59.00. XQ plug designed for 1, 2 or 3-pole breakers use. Enclosures available from stock. For factory installed breakers, add enclosure and breaker prices together and add 20% to the total. When ordering circuit breaker bus plugs complete with breaker, factory-installed, allow time for assembly and SPECIFY enclosure frame size, phase and ampere rating. Example: One XEC3100—ED2—3P—70A—factoryassembled. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog “On-Off” bus plug, pressure-sensitive labels, W47185: $6.20 per pair. Ground kit bonded ground Catalog Number W62891. List price $56.00. W63810 required when used on “XL” busway list price $16.20. Breaker cover for XQ Bus Plugs, XQBRKCVR: List Price $57.00. Discount Schedule BPLU Busway Power Distribution XL-X®, XL-U®, BD® Plug-In Units Selection Circuit Breaker Plugs Floor Operable 3-Phase, 3-Wire 3-Phase, 4-Wire Enclosure Only Enclosure Only Catalog Number XL-X Catalog Number XL-U Catalog Number List BD Price $ Plug-In REC3100G UEC3100G 833.00 BEC3100 671.00 REC4100G UEC4100G 995.00 BEC4100 822.00 RFC3250G UFC3250G 1748.00 BFC3250 1562.00 RFC4250G UFC4250G 2025.00 BFC4250 1828.00 RJC3400G UJC3400G 4270.00 BJC3400 4039.00 RJC4400G UJC4400G 4758.00 BJC4400 4886.00 LXD6 450–600 RLC3600G ULC3600G 4514.00 BLC3600 4191.00 RLC4600G ULC4600G 5058.00 BLC4600 4990.00 LD6 250–600 UMC3800G 5266.00 BMC3800 5012.00 RMC4800G UMC4800G 5994.00 BMC4800 5792.00 Breaker Type AC Ampere Volts Rating ED2 240 15–60 70–100 ED4 480 15–60 70–100 List Price $ Catalog Number XL-X Catalog Number XL-U Catalog Number BD Plug-In List Price $ List Price $ 15–60 70–100 ED6 FD6, FXD 600 JXD6 70–250 200–400 JXD2 240 JD6 200–400 200–400 BUSWAY SYSTEMS 400–600 RMC3800G 700–800 MD6 I-T-E Fusible Vacu-Break® Switch Plugs Floor-Operable with Line Terminal Protection Ampere Rating 030 060 100 Volts 250 AC or 250 DC 200 400 600 030 060 100 200 400 400 600 600 AC 3-Phase, 3-Wire Horsepower Ratings Catalog Standard Maximum (NEC) (Time Delay) 003 0071⁄2 0071⁄2 015 015 030 025 060 050 125 075 200 0071⁄2 020 015 050 030 075 060 150 125 350 125 350 200 500 Catalog Number XL-X RV321G RV322G RV323G RV324G RV325G RV326G RV361G RV362G RV363G RV364G RV365G RV365SG RV366G Fuse Adapter Kits — RV and UV 240V AC/250V DC Class “J” Amper- Catalog age Number 30 60 100 200 400 600 W49813 List Price $ — — — — — 459.00 W49813 — — — — — 459.00 Class “T” Catalog List Number Price $ — — TFAK32 76.00 TFAK42 102.00 TFAK52 102.00 TFAK62 120.00 Class “R” Catalog Number W56626 W56628 W55365 W55366 W55367 W55368 List Price $ 72.00 91.00 61.00 61.00 91.00 91.00 W56627 W56629 W55365 W55366 W55367 W55368 101.00 85.00 61.00 61.00 91.00 91.00 TFAK35 TFAK45 TFAK55 TFAK65 — — 120.00 143.00 151.00 174.00 Grounding Finger — See table. available from stock. For factory installed breakers, add enclosure and breaker prices together and add 20% to the total. When ordering circuit breaker bus plugs complete with breaker, factory-installed, allow time for assembly and SPECIFY enclosure frame size, phase and ampere rating. Example: One UEC3100—ED4—3P—70A–factory assembled Bus plugs 400A and smaller require one plug-in opening. 600–800A require two plug-in openings. Enclosures Discount Schedule BPLU List Price $ 873.00 950.00 1376.00 2225.00 5569.00 8051.00 950.00 1017.00 1398.00 2359.00 5938.00 5938.00 7996.00 List Price $ 763.00 822.00 1251.00 2118.00 5486.00 7604.00 822.00 891.00 1274.00 2246.00 5856.00 — 7662.00 3-Phase, 4-Wire Horsepower Ratings, AC Standard Maximum (NEC) (Time Delay) 003 0071⁄2 0071⁄2 015 015 030 025 060 050 125 075 200 005 015 015 030 025 060 050 125 100 150 100 150 150 400 Field Addable Ground Kits for BD Bus Plugs Fusible 600V 30 60 100 200 400 600 XL-U UV321G UV322G UV323G UV324G UV325G UV326G UV361G UV362G UV363G UV364G UV365G UV365SG UV366G Catalog Number BD Plug-In BOS14321 BOS14322 BOS14323 BOS14324 BOS14325 BOS14326 BOS14351 BOS14352 BOS14353 BOS14354 BOS14355 — BOS14356 Ampere Rating 30–60 100 200 400 600 Catalog Number W63231 W63232 W63233 W63234 W63234 List Price $ 109.00 154.00 154.00 173.00 173.00 Circuit Breaker BEC W63553 173.00 BFC W63554 173.00 BJC W63238 263.00 BLC W63238 263.00 BMC W73534 168.00 Note: These are for use on busway with internal ground bus manufactured after March, 1986. For ground kits prior to this date, consult local sales office. To order 400A fusible plug with increased wire space, add “S” to the catalog number. Example: UV365SG, UV465SG. Channel Spacers — Must be used with bus plugs mounted on 600, 800, or 1000 ampere ABD busway or on 800 or 1000 ampere BDP busway. Catalog Number W37940 list price $8.90 14 600 Catalog Number XL-X RV421G RV422G RV423G RV424G RV425G RV426G RV461G RV462G RV463G RV464G RV465G RV465SG RV466G XL-U UV421G UV422G UV423G UV424G UV425G UV426G UV461G UV462G UV463G UV464G UV465G UV465SG UV466G List Price $ 1017.00 1040.00 1510.00 2539.00 6240.00 8230.00 1063.00 1096.00 1554.00 2605.00 6397.00 6397.00 8287.00 Catalog Number BD Plug-In BOS16421 BOS16422 BOS16423 BOS16424 BOS16425 BOS16426 BOS16451 BOS16452 BOS16453 BOS16454 BOS16455 — BOS16456 List Price $ 937.00 961.00 1389.00 2431.00 6437.00 8463.00 971.00 1007.00 1424.00 2500.00 6599.00 — 8521.00 Fuse Adapter Kits — BOS 240V AC/250V DC Amperage 30 60 100 200 400 600 Class “J” Catalog List Number Price $ — — W49827 131.00 W49819 131.00 W49814 330.00 W49813 459.00 Class “T” Catalog List Number Price $ — — TFAK32 76.00 TFAK42 102.00 TFAK52 102.00 TFAK62 120.00 Class “R” Catalog Number W56626 W56628 W55365 W55366 W55367 W55368 W49832 W49830 W49828 W49818 W49816 W49815 W56627 101.00 W56629 85.00 W55365 61.00 W55366 61.00 W55367 91.00 W55368 91.00 List Price $ 72.00 91.00 61.00 61.00 91.00 91.00 600V 30 60 100 200 400 600 163.00 163.00 131.00 163.00 395.00 330.00 TFAK35 TFAK45 TFAK55 TFAK65 — — 120.00 143.00 151.00 174.00 When BD busway capacity exceeds 400A for aluminum or 600A for copper, capacity must be specified to obtain proper number and arrangement of neutral fingers. Not required. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-57 Busway Power Distribution XL-X®, XL-U® and BD® Plug-In Units Selection Shipping Weights — Pounds For Circuit Breaker Bus Plugs Only Breaker Type Ampere Rating Shipping Weights — Pounds For Fusible Switch Bus Plugs Only 3-Phase, 3-Wire 3-Phase, 4-Wire 3-Phase, 3-Wire 3-Phase, 4-Wire Enclosure Only Enclosure Only XL-X XL-U BD, LO-X XL-X XL-U BD, LO-X Switch Ampere Rating Prefix RV UV Prefix BOS Prefix RV UV Prefix BOS 30,60 100 200 400 600 17 17 36 165 165 15 18 34 111 111 19 19 38 160 170 12 18 36 112 112 Complete Assembly Complete Assembly XL-U BD, XL-U BD, XL-U BD, XL-U BD, XL-X LO-X XL-X LO-X XL-X LO-X XL-X LO-X 15–100 12 14 13 9 13 15 14 10 FD6 70–250 1 27 51 37 45 28 55 38 JXD6 JXD2 JD6 200–400 200–400 200–400 90 90 95 35 35 39 102 102 117 57 57 61 95 95 100 36 36 40 107 107 122 58 58 62 LXD6 LD6 450–600 450–600 140 140 39 39 175 175 691 61 147 147 40 40 182 182 62 62 MD6 400–800 140 79 175 114 147 80 182 115 Special Bus Plugs Catalog Number Description Ground Detector and Potentializer– For 2 or 3-pole 240 and 480 Volt service. 14 ED2, ED4, ED6 XL-U XL-X BD, LO-X List Price $ UPGR314G RPGR314G PGR6314 1137.00 BUSWAY SYSTEMS Accessories Description Channel Spacers–Must be used with Bus Plugs or Plug-in Branch-Run Adapters mounted on 600-, 800- or 1000-ampere ABD Busway or on 800- or 1000-ampere BDP Busway. 4 per package “ON-OFF” Bus Plug Stickers – Pressure sensitive, per pair. Catalog Number List Price $ W37940 8.90 W47185 6.20 BD Bus Plug Catalog Number Reference Catalog Number ABD4 Busway 225 400 ABD402 ABD404 BJC44001 — BJC44002 — BJC4400G1 — BJC4400G2 — — ⻫ BFC46001 — — BFC46002 — — BFC4600G1 — — BFC4600G2 — — BMC48001 — — BMC48002 — — BMC4800G1 — — BMC4800G2 — — BOS164251 — BOS164252 — — ⻫ BOS16425G1 — BOS16425G2 — — ⻫ BOS164261 — — BOS164262 — — BOS16426G1 — — BOS16426G2 — — BOS164551 — BOS164552 — — ⻫ BOS16455G1 — BOS16455G2 — — ⻫ BOS164561 — — BOS164562 — — BOS16456G1 — — — ⻫ BOS16456G2 — — — 14-58 — ⻫ 600 ABD406 ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ 800 ABD408 — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ 1000 ABD410 ⻫ 1200 ABD412 ⻫ BDP4 Busway 225 400 BDP402 BDP404 — 600 BDP406 800 BDP408 1000 BDP410 — ⻫ — ⻫ — ⻫ — ⻫ — — ⻫ — ⻫ — ⻫ — ⻫ — — — ⻫ — — — ⻫ — ⻫ — ⻫ — — — ⻫ — ⻫ — — — ⻫ — ⻫ — ⻫ — — — — ⻫ — ⻫ — — — — ⻫ — ⻫ — — — — ⻫ — ⻫ — — — — ⻫ — ⻫ — — ⻫ — ⻫ — — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — — ⻫ — ⻫ — ⻫ — ⻫ — — — ⻫ — ⻫ — — — ⻫ — ⻫ — ⻫ — — — ⻫ — ⻫ — — — ⻫ — ⻫ — ⻫ — — ⻫ — ⻫ — — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — — ⻫ — ⻫ — ⻫ — ⻫ — — — ⻫ — ⻫ — — — ⻫ — ⻫ — ⻫ — — — — — — — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — — ⻫ — ⻫ — ⻫ — — — Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1350 BDP413 ⻫ 1600 BDP416 ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — ⻫ — — Discount Schedule BPLU Busway Power Distribution XL-X ® , XL-U®, BD® Cubicles Selection Cubicles Molded Case Circuit Breakers (For Use With All Types of Busway) List Price $ — With Breaker Breaker Type Ampere Rating 3-Phase, 4-Wire 120/280V AC 277/480V AC 3-Phase 600V AC ET Heavy Duty JD6 200–400 13433. 14093. MD6 400–600 700–800 22939. 23496. 24092. 24675. PD6 800 1000 1200 1400 1600 26867. 29097. 34129. 37488. 38045. 28135. 30543. 35840. 39364. 39947. RD6 1800 2000 43634. 44763. 45826. 46993. 150–225 250–400 19947. 22939. 20948. 24079. CLD6 450–600 38895. 40833. CMD6 400–800 39895. 41885. CPD6 800 1000 1200 1400 1600 40884. 44877. 51860. 53051. 53849. 42937. 47120. 54457. 55712. 56548. CRD6 1800 2000 56447. 56840. 59273. 59692. CJD6 14 Current-Limiting BUSWAY SYSTEMS Note: Additional molded case circuit breakers not listed may be used. Consult local sales office for availability. Fusible Switch — Vacu-Break® Bolted Pressure Switches 3-Phase, 3-Wire 3-Phase, 4-Wire 250 Volts AC 600 Volts AC 120/208 Volts AC Ampere 480 Volts AC Rating 3-Pole 4-Pole 277/480 Volts AC Ampere Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 200 400 600 800 1200 FC3022 FC3042 FC3062 — — 8351.00 9593.00 11266.00 — — FC3025 FC3045 FC3065 FC3085 FC3125 9010.00 10367.00 12166.00 19200.00 23370.00 FC4022 FC4042 FC4062 — — 9809.00 11280.00 13243.00 — — FC4025 FC4045 FC4065 FC4085 FC4125 10594.00 12179.00 14295.00 22558.00 27464.00 Power Circuit Breaker Breaker Frame Size Maximum Ampere Rating 600 Volts AC 3-Pole 4-Pole 800 28613. 29185. 30330. 30901. 1200 32905. 33562. 34878. 35538. 1600 35765. 36481. 37912. 38627. 2000 42919. 43777. 45493. 46352. 2500 51504. 52532. 54593. 55624. 3000 65809. 67126. 69758. 71073. 4000 94422. 96311. 100087. 101975. No fuses supplied with fusible cubicles. AC Interrupting Capacity Symmetrical (RMS) Amperes List Price $ With Breaker 240 Volt 480 Volt 600 Volt 3-Phase, 3-Wire 3-Phase, 4-Wire 30,000 50,000 65,000 65,000 85,000 30,000 50,000 65,000 65,000 85,000 30,000 50,000 65,000 65,000 85,000 39541. 69210. 75534. 158190. 237286. 43495. 76130. 83086. 174007. 261011. 200,000 200,000 200,000 200,000 200,000 200,000 200,000 200,000 200,000 57347. 197731. 276827. 63075. 217502. 304506. Type RL RL-800 RL-1600 RL-2000 RL-3200 RL-4000 800 1600 2000 3200 4000 Type RLF (Fused) RL-800 RL-3200 RL-4000 800 3200 4000 Cubicle pricing includes labor and material for: 1. Single cubicle frame section complete with required busway openings. 2. Circuit breaker or fusible switch. 3. Mounting of circuit breaker or fusible switch and line-side connections. Figure busway footage through cubicle to compensate for load-size connections. For other options, consult local sales office. For Discount Schedule BUSW electrically operated, specify control voltage. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-59 Busway Mobile Industrial Power Industrial Trol-E Duct ® Selection / Dimensions General 2 and 3-Pole 100/150 Amperes 600 Volt AC, 250 Volt DC Standard Duty TD310 Catalog Number List Price $ Ship. Weight (lbs.) TD210 TD310 1001.00 1128.00 40 40 2-pole, 10 foot 2-pole, 10 foot — sectionalizing TD210R TD210RS 1204.00 1432.00 45 45 3-pole, 10 foot TD310R 1357.00 45 3-pole, 10 foot — sectionalizing TD310RS 1614.00 45 TD010 TD010R 800.80 963.20 36 36 Hanger — 2 and 3-pole Intermediate Hanger End Plate Feed-In Adapter — 2 and 3-pole TDH3 TRH31 TRB23 TDF3 79.00 43.00 53.00 150.00 04 01 003⁄4 04 Insulated Ramp Ends (pair) — 510.00 — W43771 — W43101 70.00 — 132.00 05 04 001⁄2 W43100 53.00 01 W43099 130.00 01 Description Standard Straight Busway Sections 2-pole, 10 foot 3-pole, 10 foot Drop-Out Sections Busless Busway And Drop-Out Sections BUSWAY SYSTEMS 14 10 foot busway 10 foot drop-out Accessories (Complete Assemblies) Replacement Parts Cover for standard hanger (contains 10 pieces) Hanger with cover (see TDH3) Bus Connector (contains 12 pieces) Feed-In Connector (top) (contains 2 pieces) Feed-In Connector (side) (contains 4 pieces) (All dimensions in inches) For inches / millimeters conversion, see Application Data Section. Busway rating is 100A continuous and 150A intermittent. Note: All busway sections, regardless of length, include: 1 hanger, 1 hanger cover, 1 set of bus connectors. Recommended loads not to exceed 25 pounds. UL listed. 14-60 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Straight Duct Sessions Less Than 10 Feet For each straight busway section less than 10 feet long: 1. Use base price of $228. list to cover special construction. 2. Take list price of standard 10-foot section of type required and prorate for footage price, figuring fractions to the next larger number of even feet, as shown below: Example: Required: 4 feet of 3-pole Trol-E-Duct, 100/150 ampere type. Base price to cover special construction . . . . . . . . . . . . . . . . .$228. Footage price ($112.00/foot) prorated from TD310 . . . . . . . . . . . . . . . . . .$448. List price for 4 feet of 3-pole extra footage . . . . . . . . . . . . . . . . . . . . .$676. Special Curved Duct Sections Curved busway sections should be figured on basis of $ 120. list per linear foot, plus $2090. set-up and engineering charge for each curved section. Any change of direction constitutes a curve and should be priced as above. Exceptions: 1. On a circle, 2 set-up charges will apply. 2. When 2 or more identical curves are required on a job, apply only one set-up charge to each group of identical curves. To find the linear footage of special curves of any number of degrees and any radius, use the formula shown below: 2R x 3.1416 x D =L 360 R = Radius in feet D = Degrees of curve L = Length of curve Example: Required: The length of a 75° curve with a radius of 51⁄2 feet. 2 x 5.5 x 3.1416 x 75 =7.199 feet 360 (charge for 8 feet). Fractions are figured to the next larger number of even feet, as price is always based on full linear feet. Flared Ends List price for each flared end on any straight or curved busway section $476. Special feed-in (required for busway sections with two flared ends) . . .$234. Discount Schedule BUSW Busway Mobile Industrial Power Industrial Trol-E Duct ® / Trolleys, Tool Hangers Selection / Dimensions 2 and 3-Pole Non-Fusible 600V AC and 250V DC Trolley Type Number Minimum of Maximum Radius Catalog Poles Amperes (feet) Number List Price $ Ship. Weight (lbs.) Standard Trolley T331 Trolleys Only Standard 2 30 5 T131 399.00 4 Standard 3 30 5 T331 406.00 4 Curve 2 60 3 T134 716.00 5 Curve 3 60 3 T334 805.00 5 Heavy Duty 2 60 5 TR1311 478.00 4 Heavy Duty 3 60 5 TR3311 530.00 4 Roller 20 5 TR1312 364.00 4 2 3 20 5 TR3312 406.00 4 Transfer 2 30 2 T25 1241.00 7 Transfer 3 30 2 T35 1308.00 7 Button 2 60 5 T132 649.00 5 Button 3 60 5 T332 659.00 5 14 Roller Heavy Duty Trolley TR331-1 Trolleys Box Hangers — — — TPTH 223.00 5 — — — TBTH Unit 292.00 6 Box Tool Hanger With SAF To Fuse 30A 240V AC 250V DC TBTH302F 455.00 7 30A 600V AC TBTH306F 760.00 8 TBTH202R 628.00 7 Roller Type Trolley TR331-2 Box Tool Hanger With Receptacle 20A 240V AC 250V DC Cleaning Trolleys Abrasive 3 — 5 ACT331 705.00 4 Brush 3 — 5 BCT331 705.00 4 Transfer Type Trolley T35 Note: When trolleys are used with auxiliary equipment that has a lower rating, the rating of the auxiliary device will govern the rating of the trolley. For example: heavy-duty trolleys (maximum 60A) used with box tool hangers having SAFtoFUSE units are limited by the fuse size to a rating of 30A. Also, trolleys used with box tool hangers having receptacles are limited by the receptacles’ rating to a rating of 20A, 480V AC or 250V DC. Button Type Trolley T332 Plain Tool Hanger Box Tool Hanger For 90A heavy duty trolleys, 2 or 3-pole, add $102. to list price above. and box tool hangers are not designed for use with curve or transfer type trolleys. They are for assembly only on standard, heavy-duty, roller or button trolleys. Plain Discount Schedule BUSW Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-61 BUSWAY SYSTEMS Plain Tool Busway Mobile Industrial Power Industrial Trol-E Duct ® Selection / Dimensions 4-Pole 100/150 Amperes 햲 480 Volt AC, 250 Volt DC Standard Duty TD410 Catalog Number Description Ship. Weight (lbs.) List Price $ Standard Straight Busway Sections TD410 ��� 44 4-pole, 10 foot TD410R ��� 49 4-pole, 10 foot — sectionalized TD410RS ��� Hanger — 4-pole Intermediate Hanger End Plate Feed-In Adapter — 4-pole TDH4 TRH31 TRB23 TDF4 ��� Insulated Ramp Ends (pair) — ��� T431 ��� W43771 — W43101 ��� 4-pole, 10 foot ��� ��� ��� 4-Pole Trolley 30A 4-pole Button Trolley Replacement Parts W43099 ��� BE W43100 ��� 41⁄4 1 3 ⁄4 41⁄4 — 4 5 4 ⁄2 1 ��� 1 ��� 1 TO Cover for standard hanger (contains 10 pieces) Hanger with cover (see TDH4) Bus Connector (contains 12 pieces) Feed-In Connector (top) (contains 2 pieces) Feed-In Connector (side) (contains 4 pieces) 49 AV AI LA BI LI TY BUSWAY SYSTEMS 14 Busway Accessories (Complete Assemblies) AN N O U N CE D Drop-Out Sections (All dimensions in inches) For inches / millimeters conversion, see Application Data Section. 햲 Busway 햳 See rating is 100A continuous and 150A intermittent. Electronic Pricing. 14-62 Note: All busway sections, regardless of length, include: 1 hanger, 1 hanger cover, 1 set of bus connectors. Recommended loads not to exceed 25 pounds. UL listed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule BUSW 15SPEEDFAX TM 2007-2008 Motor Control Centers Contents TIASTAR™ Motor Control Center Product Overview Technical / Dimensions 15-2 – 15-5 15-6 – 15-10 Motor Control Center Replacement Units Aftermarket Overview 15-11 – 15-14 15 MOTOR CONTROL CENTERS Residential Commercial Industrial TIASTAR™ Motor Control Center MOTOR CONTROL CENTERS 15 Overview of TIASTAR Siemens Energy & Automation introduces the TIASTAR (tie-star) Motor Control Center to meet the growing needs of our consumers. The TIASTAR MCC enhancements have been created from listening to our customers and offering a wider selection of options. Providing the best of Siemens’ proven motor control centers (MCCs), System 89 and Model 95+, TIASTAR is designed to be the industry’s leading value. From its sturdy metal cabinet to the best-of-breed Siemens technology within, TIASTAR has no equal. Siemens’ TIASTAR MCC with PROFIBUS-DP communications combines heavy-duty industrial construction and user friendly features to deliver detailed diagnostics and control by communicating between MCC units and a PLC or DCS. Unlike other manufacturers’ network offerings, Siemens’ offering is non-proprietary and is designed to simplify, not complicate, your life. So whatever you need, you can rest assured that your TIASTAR MCC can meet your needs. While we think Siemens’ TIASTAR MCC is a wise investment, it is important for you to know that advanced capabilities can be added any time during the life of the product. Siemens doesn’t think you should pay for pre-wiring or design features that don’t have an immediate payback. TIASTAR Motor Control Center 15-2 Product Overview General Features and Benefits The most effective means for grouping low voltage motor starters, associated control and distribution equipment is through the use of motor control centers. Siemens MCCs allow grouping this equipment in a common sheet steel enclosure. All 36" motor starter units (through NEMA Size 5 for FVNR) and all feeder disconnects through 250 amperes can be mounted with drawout construction. All devices within the MCC are powered from a common horizontal bus and three phase vertical bus located in each section. Once installed in its centralized operating plant location, manual supervision and monitoring can be performed safely, and remote supervision can be provided through the Siemens ACCESS™ data communication system. Domestic Design Standards The following are the principal domestic standards which apply to motor control center design, testing, construction and application. The TIASTAR Motor Control Center complies fully with the latest version of all these standards. NEMA AB-1 Molded Case Circuit Breakers ICS 1 General Standards for Industrial Control ICS 2 Standard for Industrial Control Devices, Controllers and Assemblies ICS 18 Standard for Motor Control Centers UL 845 Motor Control Centers 508 Industrial Control Equipment 891 Switchboard Design 94 Test for Flammability of Plastic Materials for Parts, Devices, and Appliances 489 Molded Case Circuit Breakers and Circuit Breaker Enclosures 991 Tests for Safety-related Controls Employing Solid-state Devices NFPA – National Fire Protection Association 70 National Electrical Code IEEE IEEE-STD-693-1997, IEEE Recommended Design Practice for Seismic Design of Substations Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Construction Details Siemens TIASTAR Motor Control Centers are composed of a number of vertical sections bolted together. That allows for future addition of MCC vertical units so the equipment can expand with customer needs. The standards structure is 90 in. (2286 mm) high, plus a 1.125 in. (29 mm) high channel sill. Front-only structures can be either 15 in. (381 mm) or 20 in. (508 mm) deep. Back-to-back mounted structures are 30 in. (762 mm) or 40 in. (1016 mm) deep, and consist of two horizontal and vertical buses. This allows for correct bus phasing on the front or rear. Siemens provides a 21 in. back-to-back design, consisting of a common horizontal and vertical bus structure, for applications where available footprint is limited. UL Listed Starters Siemens offers a wide range of UL Listing for the industry – from NEMA Size 0 through 6, including reduced voltage, two-speed, wye-delta and part-winding type starters. Drives and Soft Starts Siemens VFD (variable frequency drives) and RVSS (reduce voltage solid state starters) are available in our MCC. The range for VFD is fractional hp to 300 hp-VT and 1hp to 600 hp for RVSS. These applications are designed to meet the robust industrial environment and are cost effective for today’s market. Power Monitoring Siemens line of power meters provides market leading technology for power quality measurement. These products continually change to meet growing needs for power quality and energy monitoring. Siemens TIASTAR MCCs are fully capable of installing any of Siemens power meters for your needs. Please review the full line of Siemens power meters at www.sea.siemens.com. Overload Protection Siemens understands customer needs vary from motor to motor. That is why we offer 4 lines of overload protection. For basic needs you can specify bi-metal ambient compensated overloads. If single phase is a concern our customers can specify ESP100, and for the most advanced motor protection, customers can consider SIMOCODE overloads that provide detailed information and control. TIASTAR™ Motor Control Center Product Overview ESP100 Solid State Overloads ESP100 solid state overload relays are self powered, requiring no separate 120V source to power the circuit board. They provide phase loss protection, fewer connection points and high repeat trip accuracy which results in longer motor life and cost savings. NEMA Class 10, 20 and 30 trip curves are available for a variety of applications. The ESP100 solid state overload provides phase loss protection for the motor by tripping within three seconds upon complete loss of one phase of a three phase motor branch circuit. Each overload has at least a 2:1 current adjustment range with the adjustment dial reading out in full load amps. In addition to the markings on the dial there are audible clicks which allow for extremely fine tuning. ESP100 overloads can be used on high voltage applications, making them ideal for use with vacuum contactors and other high voltage control. ESP100 overloads can be retrofitted on existing contactors using the retrofit plate suffixes or on other brands using the plates listed in the competitive retrofit plates table on page 16-48. The SIMOCODE Pro consists of two device series with different levels of functionality: SIMOCODE Pro C (Compact) The compact motor management system can be used for Full Voltage Nonreversing (FVNR) starters, Full Voltage Reversing (FVR) starters, and base overload functionality. Bimetal Ambient Compensated Overload SIMOCODE Pro C CT Module MOTOR CONTROL CENTERS ESP100 panel mounted overloads can be used to upgrade existing starter applications where panel mounted thermal overloads are used. In addition, ESP100 overloads can be panel mounted when used with other types of controllers, such as DP, IEC contactors, and soft starts. Thermal Overloads Bimetal Ambient Compensated Bimetal ambient compensated overload relays protect both the motor and equipment by opening the control circuit when the motor experiences an overload condition. The bimetal overload relay may be set for either manual or automatic reset and can be supplied with standard Class 20 heater elements or optional Class 10 heater elements as required. An ambient compensated model of the bimetal overload is available. 15 The heaterless construction of these overloads minimizes energy costs and the costs of cabinet ventilation or cooling. Solid state overloads can be used at temperatures from – 30°C to ѿ70°C and are rated for 50Hz and 60Hz applications. SIMOCODE Pro SIMOCODE Pro is the latest generation of Motor Management System (“Smart Overload”) bringing a new level of flexibility and functionality within the Siemens smart motor control center. By means of a PROFIBUS DP interface, it can easily be linked to higher-level automation systems. SIMOCODE Pro implements all motor protection and control functions, determines operational, diagnostic and statistical data and organizes the communication between the automation system and MCC bucket. Keypad (Door Mounted) SIMOCODE Pro V (Variable) The variable motor management system has an even greater range of functions, including voltage and power monitoring and expandable modules for additional I/O, as well as temperature and ground fault protection. CT Module Expandable Module SIMOCODE Pro V Keypad (Door Mounted) Note: For detailed information on the SIMODE Pro please contact the local Siemens Sales Office. ESP100 Solid State Overload Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 15-3 Motor Control Centers Product Overview Quality Features Exceed Standards 햷 햸 MOTOR CONTROL CENTERS 15 햲 햳 햹 햴 햺 햻 햵 햽 햶 15-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Motor Control Centers Product Overview 햲 For ease in wiring and inspection, terminal blocks are mounted on a swing-out side barrier. 햳 A racking lever on all plug-in units ensures that they are fully engaged with the vertical bus. An interlock with the disconnect device ensures that a plug-in unit is not inserted or removed from the vertical bus when the unit is energized. 햴 Copper bus and heavy-duty insulators safely distribute power to sections. Copper bus, standard throughout, is conservatively rated at 50-degree rise and provides up to an optional 100,000A withstand capacity. A positive stop in the “TEST” position indicates that a plug-in unit is fully withdrawn from the vertical bus. Pilot devices are mounted on a sturdy formed-metal panel attached with two captive screws to the MCC unit door for easy access to internal components. For unit removal and test, the pilot device panel is easily removed from the door and mountd on the unit. 햹 A copper clip on plug-in units engages and grounds units at all times. 햺 The unit disconnect operating handle features a simple, rugged design. “ON” and “OFF” are clearly indicated by position, color and word. The “TRIP” indication is clearly displayed on circuit breaker equipped units. 햻 A screwdriver operated defeater mechanism allows access to an energized unit by authorized personnel. 햽 All doors swing open a minimum of 110° for easy unit access and removal. A positive stop mechanism prevents the unit from falling out of the structure during unit removal. Important Additional Features: 쐍 All wiring and components meet or exceed the requirements of UL, CSA, ENEMA, EEMAC, and NEC 쐍 Pre-wired components are professionally harnessed to industrial terminal blocks 쐍 Full depth wire tie rods are standard in each vertical wireway 쐍 White interior increases visibility for easy wiring, maintenance and inspection 쐍 Modular units are fully interchangeable 쐍 Each TIASTAR MCC is designed to satisfy your most exacting specifications 쐍 White on black base operating handle is easy to identify Plug-in unit stab assemblies include self-aligning stab clips with spring steel backup springs. Wires from the stab clips to the line-side of the circuit breaker or disconnect switch are contained in the stab housing and are isolated phase-to-phase until the wires enter the MCC. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 15-5 MOTOR CONTROL CENTERS 햶 햸 Horizontal bus design keeps the bus in the top 12" of the structure, never behind units, for easy maintenance and accessibility. 15 햵 햷 The horizontal bus compartment is isolated from the horizontal wireways by a crystal clear polycarbonate barrier that makes visible and infrared maintenance inspection a breeze. The barrier is easily removed when access to the horizontal bus is required. TIASTAR™ Motor Control Centers Technical / Dimensions MOTOR CONTROL CENTERS 15 Dimensions Height: 91.125 in. (2318 mm) (Front Mounted Only Structure) Width: 20 in. (508 mm) 24 in. (610 mm) 30 in. (762 mm) Depth: Standard: 15 in. (381 mm) Optional: 20 in. (508 mm) Optional:* 31 or 41 in. (762 or 1016 mm) *(Front mtd. only structures mtd. Back-to-Back) (Back-to-Back structure) Width: 20 in. (508 mm) 30 in. (762 mm) Depth: 21 in. (533 mm) Vertical Wireway Height: 72 in. (1829 mm) Width: 4 in. (127 mm) Depth: 10 in. (203 mm) Cross Section: 38.25 square in. (972 square mm) Top Horizontal Wireway Front Mounted Only and Back-to-Back Mounted Height: 12 in. (305 mm) Depth: 7 in. (178 mm) Bottom Horizontal Wireway Front Mounted Only Height: 6 in. (152 mm) Depth: 15 in. (381 mm) 20 in. (508 mm) or Back-to-Back Mounted Height: 6 in. (152 mm) Depth: 30 or 40 in. (762 or 1016 mm) Structural Gauge Chart Structural Parts Divider Sheets . . . . . . . . . . . . . . . . . . . . . . . . .14 Side Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Center Bottom Cross Ties . . . . . . . . . . . . . . . .12 Rear-Channel (Front Mounting only) . . . . . . . . . . . . . . .13 Channel Sills . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Center-Top Channel . . . . . . . . . . . . . . . . . . . . .13 Vertical Bus Mounting Angles . . . . . . . . . . . . .14 Lifting Angles . . . . . . . . . . . . . . . . . . . . . . . . . .7 Rear Covers . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Top Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 End Covers . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Separator Angles . . . . . . . . . . . . . . . . . . . . . . .12 Shelf Brackets . . . . . . . . . . . . . . . . . . . . . . . . .10 ga. ga. ga. ga. ga. ga. ga. ga. ga. ga. ga. ga. ga. Plating All power bus, copper tin-plated as std. Silver plating available by request. Horizontal Bus Ampere Ratings Standard: Optional: Vertical Bus Ampere Ratings Standard: Optional: ga. ga. ga. ga. ga. Finish (Ext.) ANSI 61 Light Gray Electrostatically applied dry powder paint is standard. 15-6 Cu Cu Cu Cu Cu Cu 300A, tin-plated 600A, Cu Neutral Bus (Bottom Mounted) Optional: Full neutral Cu Optional: Neutral landing pad Ratings: 600A to 1600A Bus Bracing Standard: Optional: 42,000A, 65,000A, and 100,000A Sym. Incoming Line Terminations Incoming line arrangements are available in many configurations from 600A to 2500A. Barriers Standard: Isolation Barrier: Grounded sheet steel with stab openings. Standard: Inserts to cover unused openings in V-bus barrier. Optional: Automatic shutter mechanism. Ground Bus (Bottom Mounted) Required for UL labeling Standard: .25 in. x 1 in. unplated Cu. Optional ground bus available up to 1200A. Vertical ground bus available as option, rating 300A. Also available with motor ground terminations. Weight Table Dimensions inches (mm) H Unit Parts Top and Bottom Unit Barriers . . . . . . . . . . . . .14 Back Pan . . . . . . . . . . . . . . . . . . . . . . . . . .13, 14 Side Barrier Plate . . . . . . . . . . . . . . . . . . . . . . .18 Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13, 14 600A, tin-plated 800A, 1200A, 1600A, 2000A, 2500A, W 20 (508) 20 (508) 91.13 20 (2315) (508) 30 (762) 20 (508) D 15 (381) 20 (508) 30 (762) 20 (508) 21 (533) Type Shipping Weight per Section in lbs. (kg) 550 lbs. (250) front only 600 lbs. (273) back-to-back 850 lbs. (386) front only 800 lbs. (364) back-to-back 900 lbs. (409) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Wiring Specifications Control on Units 16 gauge 19 strand bonded copper 105°C – 600V Interconnection Control Wiring Between Units 14 gauge 19 strand copper 105°C – 600V Power Wiring – Sized to suit maximum HP rating of unit 12 gauge to 2 gauge 19 strand copper 105°C – 600V 1 gauge to 500 MCM 19 strand to 37 strand copper 105°C – 600V Enclosure Types NEMA 1 (Standard) – Indoor NEMA 1A Gasketed – Indoor NEMA 2 – Drip-proof – Indoor NEMA 12 – Dust tight – Indoor NEMA 3R – Rainproof – Outdoor (Non-walk-in) MCC Shutter Mechanism Automatic shutter mechanisms when specified will be supplied at the stab in location of each plug-in unit and requested future space. Unused stab openings will be covered with snap-in hole plugs. Pull Box (Top Hat) Available in 12 in., 18 in. or 24 in. high; 20 in. or 30 in. wide; 15 in. or 20 in. deep. Motor Control Centers Wiring Classifications Siemens MCC’s are available as either Class I or Class II assemblies utilizing either Type A, Type B, or Type C wiring as defined in NEMA ICS18-2001(3.1) and NEMA ICS18-2001(3.3). Below are the NEMA class and type definitions: Class I-S and II-S — Motor Control Centers With Custom Drawing Requirements (NEMA ICS18-2001(3.2.3)) Class I-S and II-S motor control centers shall be the same as Class I and II except custom drawings shall be provided in lieu of standard drawings as specified by the user. Examples of custom drawings are: ▪ Special identifications for electrical devices ▪ Special terminal numbering designations ▪ Special sizes of drawings The drawings supplied by the manufacturer shall convey the same information as drawings provided with Class I and II motor control centers, additionally modified as specified by the user. Types of Wiring — NEMA ICS182001(3.3.1) Type A (NEMA ICS18-2001 (3.3.1.1)) User field wiring shall connect directly to device terminals internal to the unit and shall be provided only on Class I motor control centers. Type C (NEMA ICS18-2001(3.3.1.3)) User field control wiring shall connect directly to master terminal blocks mounted at the top or bottom of those vertical sections that contain combination motor control units or control assemblies which shall be factory wired to their master terminal blocks. User field load wiring for combination motor control units, size 3 or smaller, shall connect directly to master terminal blocks mounted at the top or bottom of vertical sections. Motor control unit load wiring shall be factory wired to the master terminal blocks. User field load wiring for combination motor control units larger than size 3, and for feeder tap units, shall connect directly to unit device terminals. IB-T IIB IB-D Type B (NEMA ICS18-2001(3.3.1.2)) a. Type B user field load wiring for combination motor control units size 3 or smaller shall be designated as B-D or B-T, according to the following: ▪ B-D connects directly to the device terminals, which are located immediately adjacent and readily accessible to the vertical wireway. ▪ B-T connects directly to a load terminal block in, or adjacent to, the unit. b. Type B user field load wiring for combination motor control units larger than size 3, and for feeder tap units, shall connect directly to unit device terminals. c. Type B user field control wiring shall connect directly to unit terminal block(s) located in, or adjacent to, each combination motor control unit. IIC IC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 15-7 MOTOR CONTROL CENTERS IA Class II — Interconnected Units (NEMA ICS18-2001(3.2.2)) Class II motor control centers shall be the same as Class I motor control centers with the addition of manufacturer furnished electrical interlocking and wiring between units as specified in overall control system diagrams supplied by the purchaser. In addition to the drawings furnished for Class I motor control centers, the manufacturer shall furnish drawings that indicate factory interconnections within the motor control center. 15 Class I — Independent Units (NEMA ICS18-2001(3.2.1)) Class I motor control centers shall consist of mechanical groupings of combination motor control units, feeder tap units, other units, and electrical devices arranged in a convenient assembly. The manufacturer shall furnish drawings that include: a. Overall dimensions of the motor control center, identification of units and their location in the motor control center, locations of incoming line terminals, mounting dimensions, available conduit entrance areas, and the location of the master terminal board if required (Type C wiring only). b. Manufacturer’s standard diagrams for individual units and master terminal boards (Type C wiring only) consist of one or more drawing(s) that: 1. Identify electrical devices. 2. Indicate electrical connections. 3. Indicate terminal numbering designations. Note: When a combination schematic and / or wiring diagram for a unit is supplied showing optional devices, the manufacturer shall provide information to indicate which devices are actually furnished. Technical / Dimensions Motor Control Centers Starter Ratings and Dimensions Technical / Dimensions MCC Starter Ratings and Dimensions Circuit Breaker Type (For Maximum HP at 460V) kA Maximum Interrupting Standard Dimensions in Inches (mm) Rating NEMA Horsepower Rating Breaker Unit Height 208 V 230 V 460 V Type W = Width, D = Depth at 480 V Size Full Voltage — UL Listed 7.5 7.5 0-1 15 10 2 30 25 3 50 40 4 5 6 7 — 10 25 50 100 15 42 / 100 MCP 75 100 200 JD6-ETI 36 (914) 72 (1829) 150 200 400 LD6-ETI 48 (1219) 72 (1829) 30W (762W) — 300 600 ND6 72 (1829) 30W × 20D (762W × 508D) Two Speed, Constant Or Variable Torque — UL Listed 10 7.5 7.5 0-1 15 25 10 2 30 50 25 3 50 100 40 4 MOTOR CONTROL CENTERS FVR 18 (457) 24 (610) 30 (762) 36 (914) IR Std./Opt. FD6-ETI FVNR 12 (305) 12 (305) 18 (457) 24 (610) — MCP FD6-ETI 5 75 100 200 JD6-ETI 6 150 200 400 LD6-ETI Two Speed, Constant Horsepower — UL Listed 7.5 7.5 0-1 15 10 2 30 25 3 50 40 4 — 10 25 50 100 MCP FD6-ETI 5 75 100 200 JD6-ETI 6 150 200 400 LD6-ETI Reduced Voltage Autotransformer Non-Reversing, Closed Transition — UL Listed 2 3 4 5 10 25 40 75 15 30 50 100 25 50 100 200 FVNR 12 (305) 12 (305) 24 (610) 42 (1067) JD6MCS / 400 72 (1829) MD6MCS / 600 72 (1829) ND6MCS / 1200 72 (1829) 40W × 20D (1016W × 508D) 72 (1829) 30W (762W) 72 (1829) 30W (762W) 72 (1829) 30W (762W) 42 / 100 JD6MCS / 400 Consult Siemens 42 / 100 MD6MCS / 600 IR Std./Opt. — 30 / 30 60 / 60 100 / 100 FD6MCS / 200 2S2W-CH 24 (610) 24 (610) 36 (914) 48 (1219) JD6MCS / 400 72 (1829) MD6MCS / 600 72 (1829) 40W (1016W) — 60 / 60 100 / 100 FD6MCS / 200 JD6MCS / 400 RVAT 42 (1067) 48 (1219) 60 (1524) 72 (1829), 30W (762W) MD6MCS / 800 72 (1829) 30W (762W) 72 (1829) 30W (762W) 72 (1829) 30W (762W) 2S1W-CH 24 (610) 24 (610) 36 (914) 48 (1219) 72 (1829) 30W (762W) Consult Siemens 6 150 200 400 LD6-ETI 72 (1829) 30W (762W) 7 300 300 600 ND6 72 (1829) 50W × 20D (1270W × 508D) 42 / 100 42 / 100 42 / 100 IR Std./Opt. 42 / 100 42 / 100 IR 100 N/A IR Std./Opt. 2S2W-CH 24 (610) 24 (610) 30 (762) 30 (762) 2S2W 24 (610) 24 (610) 36 (914) 48 (1219) 72 (1829) 30W (762W) kA Interrupting Rating at 480 V 72 (1829) 30W (762W) 2S1W 24 (610) 24 (610) 36 (914) 48 (1219) 42 / 100 — 30 / 30 60 / 60 100 / 100 FD6MCS / 200 FVR 18 (457) 24 (610) 36 (914) 48 (1219) 72 (1829) 30W (762W) 2S2W 24 (610) 24 (610) 30 (762) 36 (914) FD6-ETI JD6-ETI MCP — 30 / 30 60 / 60 100 / 100 FD6MCS / 200 42 / 100 N/A RVAT 42 (1067) 42 (1067) 48 (1219) 72 (1829), 30W (762W) — 42 / 100 Fusible Type (For Maximum HP at 460V) Standard Disconnect Dimensions in Inches (mm) Sw/Fuse Unit Height Clip Sizes W = Width, D = Depth 2SW1 24 (610) 24 (610) 48 (1219) 60 (1524) 72 (1829) 30W (762W) IR 100 Consult Siemens 72 (1829) 40W (1016W) 2SW1-CH 24 (610) 24 (610) 48 (1219) 60 (1524) 72 (1829) 30W (762W) Consult Siemens IR 100 IR 100 42 / 100 Two Step Part Winding, Star Connected — UL Listed 10 10 15 1 20 40 25 2 40 75 50 3 150 75 75 4 — MCP RVPW 72 (1829) ND6MCS / 1200 50W × 20D (1270W × 508D) IR Std./Opt. 24 (610) JD6-ETI 36 (914) 36 (914) 42 / 100 — 60 / 60 100 / 100 FD6MCS / 200 JD6MCS / 400 5 125 150 350 LD6-ETI 72 (1829) 42 / 100 LD6MCS / 600 6 — 250 500 MD6 72 (1829) 30W (762W) 42 / 100 MD6MCS / 600 The addition of oversize CPT’s (above 50VA), relays, timers, etc. may increase unit height. Consult Siemens for other voltages. Interrupting ratings are 25 kAIC when not UL Listed. Stationary units (not plug-in). Fixed mounted unit – space behind not available. Based on each winding handling 50%. Consult Siemens for other ratings. Note: For Half Size Starters, contact Siemens. 15-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog RVPW 24 (610) 24 (610) 48 (1219) 72 (1829) 72 (1829) 30W (762W) 72 (1829) 30W (762W) IR 100 Motor Control Centers Starter Ratings and Dimensions Technical / Dimensions MCC Starter Ratings and Dimensions (cont'd) Maximum NEMA Horsepower Rating Size 208 V 230 V 460 V Circuit Breaker Type (For Maximum HP at 460V) kA Standard Dimensions in Inches (mm) Interrupting Breaker Unit Height Rating Type W = Width, D = Depth at 480 V Reduced Voltage Wye Delta, Open and Closed Transition 20 25 40 2 60 25 30 3 125 60 60 4 5 150 150 300 Solid State Reduced Voltgage Open and Closed Transition — MCP MCP FD6-ETI YDO 30 (762) 30 (762) 36 (914) YDC 42 (1067) 42 (1067) 48 (1219) LD6-ETI 72 (1829) 30W (762W) 72 (1829) 30W (762W) 1 2 7.5 10 7.5 15 10 25 — CED6-ETI CED6-ETI 3 25 30 50 CED6-ETI 36 (914) 4 40 50 100 CFD6-ETI 36 (914) 5 75 100 200 CJD6-ETI 6 150 150 350 CLD6-ETI IR Std./Opt. 42 / 100 42 / 100 42 / 100 — 100 / 100 250MCS / 200 400MCS / 400 42 / 100 600MCS-600 IR Std./Opt. — (30 / 30) (60 / 60) (ED MCS / 100) 18 (457) 36 (914) 72 (1829) (ED MCS / 100) 72 (1829) Structure W×D 24 (610) (Plug-in) 36 (914) (Plug-in) 20 (508) × 15 (381) 48 (1219) (Plug-in) 60 (1524) (Recessed Panel, Fixed Mounted) 72 (1829) (Recessed Panel, Fixed-Mounted) 20 (508) × 20 (508) 50 (1270) × 20 (508) Lighting Panelboards Applied in MCC’s Number Amp Of Rating Circuits Main Lug Only 18 225 30 42 Main Breaker 18 225 30 250 42 Height In Inches (mm) 1Ø, 3W 3Ø, 4W 3Ø, 4W Panel 240/120 208Y/120 277/480 1 to 18 30 (762) 30 (762) 1 to 30 36 (914) 36 (914) 1 to 42 42 (1067) 42 (1067) 30 (762) 36 (914) 42 (1067) 1 to 18 30 (762) 30 (762) 30 (762) 1 to 30 36 (914) 36 (914) 36 (914) 1 to 42 42 (1067) 42 (1067) 42 (1067) Distribution Transformers kVA Rating 1 1.5 2 3 5 7.5 10 15 25 30 37.5 9 15 25 30 45 Phase Unit Height In Inches (mm) Plate-Mounted in 12 in. (305 mm) space 1 18 (457) 24 (610) 24 (610) 12 (305) 3 18 (457) 24 (610) Transformer mounted on brackets 6 in. (152 mm) off sills. Requires 20 in. (508 mm) deep structure. For other available voltage ratings, consult Siemens. For other enclosure types, consult Siemens. Ratings are for variable torque applications. Consult Siemens for other applications. Dimensions shown are for circuit breaker or fusible disconnects. Drives with bypass and / or isolation require extra mounting space. Consult Siemens for further information. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 15-9 MOTOR CONTROL CENTERS Rated Amperes 4 8.5 7.6 11 14 19 23 25 32 34 34 45 46 52 75 240 Max. 185 Max. 370 Max. Dimensions—In. (mm) Mounting Height 18 (457) (Plug-in) 100 15 480V Variable Frequency Drives — NEMA 1A MCC Enclosures 100 36 (914) 60 (1524) Requires 30 in. (762 mm) wide structure. and / or isolation requires additional space. 15 HP at 230V requires additional unit space. Consult Siemens. The addition of relays, timers, etc. will require additional space. Unit includes rated line side isolation starter and J fuses. IR IR (ED MCS / 100) 42 / 100 kA Interrupting Rating at 480 V 18 (457) 36 (914) 48 (1219) IR Std./Opt. YDC 48 (1219) 60 (1524) 72 (1829) 72 (1829) 30W (508W) 60 (1524) Bypass Drive Type MM440 MM440 5 MM440 MM440 7.5 MM440 10 MM440 MM440 15 MM440 MM440 20 MM440 25 MM440 MM440 30 MM440 MM440 40 MM440 50 MM440 60 MM440 75-125 MM440 150-300 YDO 36 (914) 48 (1219) 72 (1829) 72 (1829) 30W (508W) (ED MCS / 100) 42 / 100 Circuit Compact Units — Available — Breaker Type Fusible Type FVNR Only — UL Listed 6 (152) 7.5 MCP 10 7.5 0-1 6 (152) may increase The 25 18unit (457)height. ED6-ETI 10 of oversize 12 (305) 15 CPT’s (above 2 addition 50VA), relays, timers, etc. Consult Siemens for30 other voltages. 50 30 (762) 15 (381) ED6-ETI 25 3 Stationary units — Not plug in. 40 50 FD6 21 (533) 100 30 (762) 4 Rating HP 2 Fusible Type (For Maximum HP at 460V) Standard Disconnect Dimensions in Inches (mm) Sw / Fuse Unit Height Clip Sizes W = Width, D = Depth Motor Control Centers Incoming Cable Space, Wiring Troughs, Wiring Terminations The National Electrical Code establishes very specific guidelines for minimum cable bending space within motor control centers. Figures 1 through 5 below describe the most common arrangements for terminating main incoming power cables in the MCC. Consult Siemens for incoming line compartment braced for 100,000 amperes symmetrical, short circuit. Technical / Dimensions Incoming Cable Space Description of Incoming Service Top or Bottom Incoming Section Cable Entry Top or Bottom Space Requirements in Inches (mm) Notes ≤ 350 kcmil Two per Phase Top — Directly on Main Bus Either None See Figure 3 See Figure 1 See Figure 1 ≤ 600 kcmil One or Two per Phase Top Either Top Wireway plus 12.0 (305) or 18.0 (457) ≤ 600 kcmil Three or Four per Phase Top Top Top Wireway plus 18.0 (457) 750 kcmil One or Two per Phase Top Top Top Wireway plus 24.0 (607) — 350 kcmil One or Two per Phase Bottom Bottom Bottom Wireway plus 18.0 (457) ≤ 600 kcmil One or Two per Phase Bottom Bottom Bottom Wireway plus 24.0 (610) Top or Bottom Either Full Structure Top Bottom See Breaker / Disconnect See Figure 4 Top Top See Breaker / Disconnect See Figure 5 Top or Bottom Either Consult Siemens Consult Siemens ≤ 750 kcmil, up to eight per phase ≤ 500 kcmil One or Two per Phase ≤ 750 kcmil One per Phase to Main Breaker ≤ 500 kcmil One to Four per Phase ≤ 750 kcmil One per Phase to Main Breaker Busway or Cable Feed to Line Reactor 600 A Maximum See Figure 2 600 A Maximum See Figure 2 Consult Siemens MOTOR CONTROL CENTERS 15 Siemens MCC’s are equipped with a 12 in. (305 mm) high, full-width horizontal wireway in the top and 6 in. (152 mm) in the bottom of each structure. A separate vertical wireway connects the top and bottom wiring areas in each vertical section. This wireway is 4 in. (102 mm) wide by 10 in. (254 mm) deep, or 38.25 (972) square inches (mm). Note: All standard Siemens termination schemes shown herein do comply with applicable cable bending requirements of UL and the NEC. Figure 1 Incoming Cable Figure 2 Figure 3 Main Lugs Main Lugs Incoming Cable Main Lugs at Top with Top Cable Entry Can accommodate up to two 600 kcmil cables per phase when using Siemens standard mechanical lugs. A total height of 24 in. (610 mm). This includes 12 in. (305 mm) for the top wireway plus 12 in. (305mm) of unit space. Compression lugs require extra vertical space or the addition of a top hat. Main Lugs at Bottom with Bottom Cable Entry Lugs are bolted directly to the bottom of the vertical bus. Can accommodate up to two 350 kcmil per phase in 24 in. (610 mm) high compartment. This includes 6 in. (152 mm) for the bottom wireway plus 18 in. (457 mm) of unit space. Can accommodate up to two 600 kcmil per phase in 30 in. (762 mm) high compartment. This includes 6 in. (152 mm) for the bottom wireway plus 24 in. (610 mm) of unit space. Figure 4 Main Disconnect with Bottom Cable Entry Main Lugs at Top with Top or Bottom Cable Entry In this arrangement the lugs mount directly on the horizontal bus, eliminating the need to use unit mounting space. The limitation here is 350 kcmil cable per phase. Figure 5 Main Disconnect with Top Cable Entry If bottom entry is used, cables must be properly laced and supported based upon the available short circuit current. See dimensional requirements for molded case breakers and fused switches, consult local sales office. 15-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Motor Control Center Replacement Units Aftermarket Overview Product Description (Time Line: 2002 — Current) Introduced in 2002, Siemens TIASTAR is an advanced SISystem™ (Smart Integrated Solution System) that provides you with seamless control of your physical plant by fusing ASI, PROFIBUS®, and ACCESS™ – as well as most legacy systems – into a robust, fully integrated management system. Units widths are normally 15" or 20" wide, and 12" tall with 6" increments. Today, we provide you with Siemens breakers and starters. The standard lead-time for delivery is 24 hrs – 3 weeks. Replacement Capabilities Starter Units Model 95+ The Model 95+ retrofit buckets are designed to fit into Model 95+ MCCs. This upgrade from Model 95 included changes in handles, color, pilot devices, and stabs. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. Today, we provide you with Siemens breakers and starters. The standard lead-time for delivery is 24 hrs – 3 weeks. Replacement Capabilities Starter Units Replacement starters are available for all plug-in and Non plug-in units. A complete unit for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT ▪ CB and Fusible ▪ Pilot Devices, VFD, Softstarts and ASI ▪ Relays, Fuses ▪ UL Labeled Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 15-11 MOTOR CONTROL CENTERS Product Description (Time Line: 1996 — 2001) 15 Replacement starter units are available for all plug-in and Non plug-in units MCC designs. A complete unit for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT & Pilot Devices ▪ CB and Fusible ▪ Relays, Fuses, VFD and Softstarts ▪ Soft Starts, SIMOCODE, ASI, PROFIBUS ▪ UL Labeled Motor Control Center Replacement Units Aftermarket Overview Product Description (Time Line: 1995 — 1997) Model 95 The Model 95 was originally manufactured in Raleigh, NC. Model 95 served as a style template for many old MCC buckets since installation procedures and dimensions stayed the same. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. The original Model came with a variety of CB and starters from ITE, C-H and Siemens 3TF & 3UA Overload. Today, we provide you with Siemens breakers and starters. The standard lead-time for delivery is 24 hrs – 3 weeks. Replacement Capabilities Starter Units MOTOR CONTROL CENTERS 15 Replacement starters are available for all plug-in and Non plug-in units. A complete unit for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT ▪ CB and fusible ▪ Pilot Devices ▪ Relays and Fuses Product Description (Time Line: 1986 — 1997) Model 90 The Model 90 retrofit buckets are designed to fit into Model 90 MCCs. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. The original Model came with a variety of CB and starters from ITE, C-H, and Siemens 3TF & 3UA Overload. Today, we provide you with Siemens breakers and starters. The standard lead-time for delivery is 24 hrs – 3 weeks. Replacement Capabilities Starter Units Replacement starters are available for all plug-in and Non plug-in units. A complete unit for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT ▪ CB and Fusible ▪ Pilot Devices ▪ Relays and Fuses 15-12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Motor Control Center Replacement Units Aftermarket Overview Product Description (Time Line: 1979 — 2001) This is an upgrade from Class 89 developed by Furnas in 1965. Bucket structures are normally 15" or 20" wide, and 12" tall with 6" increments. The original System 89 came with a variety of CB and starters from Westinghouse, GE and Furnas Electric. Today, we provide you with Siemens breakers and starters. The standard lead-time for delivery is 24 hrs – 3 weeks. Replacement Capabilities MCC Plant: West Chicago Starter Units The Marq21 retrofit buckets are designed to fit into Marq21 MCCs. Marq21 was created from the forge of two of the world’s foremost electrical companies, Siemens-Allis. Units widths are normally 15" or 20" wide, and 12" tall with 6" increments. The original Marq21 came with a variety of CB and starters from ITE and Allis-Chambers. The standard lead-time for delivery is 24 hrs – 3 weeks. Note: Original components are not available. Today, we provide you with Sentron breakers and Siemens starters. Replacement Capabilities Starter Units Replacement starters are available for all plug-in and Non plug-in units. A complete units for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT ▪ CB and fusible ▪ Pilot Devices ▪ Relays and Fuses ▪ UL Labeled Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 15-13 MOTOR CONTROL CENTERS Product Description (Time Line: 1975 — 1996) 15 Replacement starter units are available for all plug-in and non plug-in unit MCC designs. A complete unit for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT ▪ CB and Fusible ▪ Pilot Devices ▪ Relay, Fuses, VFD and Softstarts ▪ UL Labeled Motor Control Center Replacement Units Aftermarket Overview Product Description (Time Line: 1972 — 1975) The Mark 2 retrofit buckets are designed to fit into their old design. This is an upgrade from the Mark 1 in ValueLine family. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. Mark 2 The original Mark 2 came with a variety of CB and starters from Westinghouse and Allis-Chalmers. The standard leadtime for delivery is 24 hrs – 3 weeks. Add-on MCCs: New TIASTAR MCC can be spliced to existing line-up. Note: Original components are not available. Today, we provide you with Sentron breakers and Siemens starters. Replacement Capabilities Starter Units MOTOR CONTROL CENTERS 15 Replacement starters are available in plug-in Non plug units. A complete unit for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT ▪ CB and Fusible ▪ Pilot Devices ▪ Relays, Fuses ▪ UL Labeled Product Description (Time Line: 1971 — 1992) 5600 The 5600 MCC retrofit buckets are designed to fit into their old design. 5600 units are 15" wide buckets and the fix mounted panels are 20" wide. The original Gould came with a variety of old CB and starters from ITE, Rowan, and AMP-CAP. These buckets are available up to NEMA size 5. The standard lead-time for delivery is 24 hrs – 3 weeks. Note: Original components are not available. Today, we provide you with Sentron™ breakers and Siemens starters. Replacement Capabilities Starter Units Replacement starters are available for all plug-in and Non plug-in units. A complete unit for adding to an existing MCC includes a unit door, divider pans and all necessary mounting hardware. Features of the replacement units include: ▪ Siemens Starter Size 1-6 ▪ CT, CPT, PT ▪ CB and Fusible ▪ Pilot Devices, Relays, and Fuses ▪ UL Labeled ▪ Shelf is ordered separately 15-14 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16SPEEDFAX TM 2007-2008 Control Products Contents 16-5 – 16-6 16-7 – 16-8 16-9 – 16-10 16-11 16-12 – 16-13 16-14 – 16-16 16-17 16-18 – 16-26 16-27 – 16-28 16-29 – 16-30 16-31 16-32 – 16-35 16-36 – 16-43 16-44 – 16-45 16-45 16-46 16-47 – 16-49 16-50 – 16-51 16-52 16-53 16-54 – 16-55 16-56 – 16-57 16-58 – 16-59 16-60 – 16-61 16-62 16-63 16-64 16-65 16-66 16-67 16-68 – 16-70 16-71 – 16-73 16-74 – 16-78 16-79 – 16-89 16-90 – 16-93 16-94 – 16-98 16-99– 16-128 16-129 – 16-147 CONTROL PRODUCTS Residential Commercial Industrial 16-3 16-4 16 What’s New Product Overview NEMA & General Purpose Control Manual Control Fractional HP Starters, Class SMF Switches, Class MMS and MRS Starters and Switches, Class 11 - 3RV NEMA Control Catalog Numbering System Non-Combination Starters Features and Benefits Non-Reversing Starters, Class 14 Combination Starters Features and Benefits Combination Starters, Class 17 and 18 Reversing Starters, Class 22 Combination Reversing Starters, Class 25 and 26 Two Speed Starters Features and Benefits Two Speed Starters, Class 30 Combination Two Speed Starters, Class 32 Non-Reversing Contactors, Class 40 Vacuum Contactors, Class 40 Reversing Contactors, Class 43 Overload Relays, Class 48, 958 and 3RB20 Current Sensitive Relays, Class 97 Duplex Controllers Features and Benefits Non Combination, Class 83 Combination, Class 84 Pump Control Panels Features and Benefits Full-Voltage Type, Class 87 Reduced-Voltage Type, Class 88 Vacuum Starter Type, Class 87 Reduced Voltage Control Reduced Voltage Features and Benefits Auto Transformer Starters, Class 36 and 37 Part Winding Starters, Class 36 and 37 Wye Delta Open Transition, Class 36 and 37 Wye Delta Closed Transition, Class 36 and 37 Lighting Control Electrically Held Contactors, LE Mechanically Held Contactors, CLM Control Power Transformers Domestic and International (UL, CSA and CE), Class MT and MTG Modifications and Drawings Field Modification Kits Enclosure Kits Factory Modifications Dimensions Wiring Diagrams 16SPEEDFAX TM 2007-2008 Control Products CONTROL PRODUCTS 16 Contents Heater Tables and Replacement Parts Overload Relay Heater Tables NEMA Coils and Contact Kits Coil VA Ratings and Overload Relays Lighting Contactor Parts and Kits Definite Purpose Control General Application - Class 42 and 45 Soft Starters Control Electronic Soft Starts, 3RW Control Products, 3RW Mods and Dimensions Wiring Diagrams Pilot Devices Class 50 Standard Duty Control Stations Introduction Standard Duty Type 1 and 1B Heavy Duty Type 4 Stations Class 50 Accessories Class 50 Standard Duty Dimension Drawings Class 52 30mm Mounting Diameter Pilot Devices Introduction Complete Pushbutton units Push-pull Mushroom Pushbuttons Indicator lights-Push to Test Lights-Illuminated Pushbuttons Pushbuttons and Push-pull Operators Selector Switch Operators Keyed Selector Switches Specialty Operators Class 52 Black Max N4-4X-13 Complete Units Pushbuttons and Push-pull Operators Selector Switch Operators Indicator lights-Push to Test Lights-Illuminated Pushbuttons Class 52 30mm Enclosed Pushbutton Stations Selector Switch Operators Cam Selection Chart for Selector Switches Custom Order Pushbutton Stations Accessories and Spare Parts Dimensional Drawings Assembled Enclosures with Standard Devices. P30 Empty Enclosures Only Enclosure Legend Plates Enclosure Dimension Residential Commercial Industrial 16-148 – 16-154 16-155 – 16-156 16-157 16-158 – 16-159 16-160 – 16-161 16-162 – 16-167 16-168 – 16-176 16-177 – 16-178 16-179 16-180 16-181 – 16-185 16-186 16-187 16-188 16-189 16-189 – 16-190 16-191 – 16-192 16-193 – 16-194 16-195 16-196 – 16-198 16-199 16-200 – 16-201 16-202 16-203 – 16-204 16-205 16-206 – 16-207 16-208 16-209 16-210 16-211 – 16-213 16-214 – 16-215 16-216 – 16-217 16-218 16-219 16-220 Control Products What’s New Catalog Enhancements ▪ Section 16 pages have been restructured according to product group for even better organization. Each product group is identified by a sub-tab on each page. The groups consist of: —NEMA & General Purpose Control —Definite Purpose Control —Soft Starter Control —Pilot Devices ▪ Class 97 Current Sensitive Relay dimensions and wiring diagram added. See pages 16-108 and 16-143. ▪ Class MRS Fractional HP Switch wiring diagrams added. See page 16-129. Class 14 with Shield Class 17 with Shield Handle and Mechanism Replacement Kits Handle & Mechanism replacement kits are now available for class 17, 18, 25, 26, & 32. The replacement kits include the operator handle, link rod, mechanism and all necessary hardware. See page 16-159. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-3 CONTROL PRODUCTS Protective Shields - Protect Against Accidental Contact with NEMA Products Protective shields can be added to open and enclosed NEMA contactors and starters, as well as fusible or non-fusible disconnect switches in combination starters and pump panels. Protective shields provide protection against accidental contact with live parts such as line and load terminals, auxiliary contacts and coil terminals. Contactor and starter shields allow access to terminals and the reset button on overloads without removing the shield. ▪ The shields are designed for use on Class 40 contactors and Class 14 starter sizes 00 to 4. ▪ The same shield used on Class 14 starters can be used on either solid state or bimetal overloads. ▪ Shields used on disconnect switches are designed for 30-200A switches in either combination starters or pump control panels. ▪ Shield covers both switch and load base fuse clips when installed. See page 16-82. 16 Enclosure Kits for Lighting & Heating Contractors Enclosure kits are now available for Class LE and CLM Lighting & Heating Contactors. These enclosure kits allow you to add value by assembling enclosed lighting & heating contactors in the field. (Contactor and modification kits are sold separately.) See page 16-91. Class 40 with Shield Control Products NEMA & General Purpose Controls Class MMS & MRS Fractional Horsepower Manual Switches Page 16-7 Class 11 Manual Starters and Switches Page 16-9 Class 22 NEMA Reversing Starters Page 16-27 Class 25, 26 NEMA Combination Reversing Starters Page 16-29 Class 30 NEMA Multi-Speed Starters Page 16-32 Class 40 NEMA Contactors and Vacuum Contactors Page 16-44 Class 43 NEMA Reversing Contactors Page 16-46 Class 48, 958, 3RB20 Overload Relays Page 16-47 Class 83, 84, 87, 88 Pump Controls Page 16-53 Class MT, MTG Control Power Transformers Page 16-74 Modifications and Drawings Page 16-79 Heater Tables and Replacement Parts Page 16-148 Class 14 NEMA Starters Page 16-14 Class 32 NEMA Combination Multi-Speed Starters Page 16-36 Class 17, 18 NEMA Combination Starters Page 16-18 Class 36, 37 Reduced Voltage Electromechanical Starters Page 16-64 CONTROL PRODUCTS 16 Class SMF Fractional Horsepower Manual Starters Page 16-5 Product Overview Class LE, CLM Lighting Contactors Page 16-68 16-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Class 97 Current Sensitive Relays Page 16-50 Manual Control Fractional HP Starters, Class SMF Class SMF Class SMF fractional horsepower starters provide overload protection as well as manual on-off control for small horsepower motors in a variety of industrial and commercial applications. Available in one or two pole versions, these devices are suitable for use with AC single phase motors up to 1 HP. Two pole starters can also be used with DC motors up to 3⁄4 HP. Typical applications include fans, conveyors, pumps, and small machine tools. Continuous Current Rating 16 amperes. Overload Trip Assembly Motor protection is provided by a Class SMFH heater element which must be installed before the starter will operate. Enclosures Class SMF, NEMA Type 1 surface mounting enclosures are sheet steel with a thermo-plastic wrap-around cover for convenience in wiring. The NEMA Type 1 enclosure is also available in an oversized version which allows more wiring space. A zinc alloy die casting is used for NEMA Type 4 enclosures. Pilot Lights Red or green neon pilot light units are available for flush mounting plates, NEMA Type 1 enclosures, and NEMA Type 4 enclosures. Pilot lights may be either factory or field installed. (For starters that contain a pilot light, a Red light is standard. For a Green pilot light add ”G” to the end of the catalog number.) Terminals Binding head screw type terminals are suitable for #10 or smaller copper wire, and are accessible from the front. All terminals are clearly marked. Operation Available with toggle handle or with removable key type operator to discourage unauthorized operation. Emergency Off Actuator A toggle operator extender is available for Class SMF, NEMA Type 1 surface mounted units. The extender has a red vinyl button that provides a fast and easy method for locating and switching the device‘s toggle operator into the OFF position. The Emergency Off Actuator is available in kit form only for field installation. Handle Guard/Lock-Off An optional handle guard on Class SMF, NEMA Type 1 enclosed starters prevents accidental operation of the toggle operator and also allows the toggle operator to be padlocked in either the “ON” or “OFF” position. This handle guard can be factory installed on NEMA Type 1 enclosed starters and is also available in kit form for field installation on NEMA Type 1 surface and flush mounting enclosures. Standard NEMA Type 4 metallic enclosures include provisions for padlocking the device in the OFF position. CONTROL PRODUCTS Mounting Open types without a pilot light fit standard single gang switch boxes, and can be used with any cover plate having a standard toggle cutout. Single-unit flush mounting types, including those with pilot lights, are suitable for wall mounting in a standard switch box or for machine cavity mounting without a box. Class SMF Starter in a NEMA Type 1 Enclosure with Pilot Light 16 Two Speed Starters Two speed manual starters are designed for control of small single phase AC motors having separate windings for high and low speed operation. Two toggle operated starters are used, with overload protection included for each motor winding. Surface mounting devices, and those with a gray flush plate, utilize a mechanical interlock which allows direct control of the motor by means of the toggle operators. General NEMA & General Purpose Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-5 Manual Control Fractional HP Starters with Melting Alloy Overload, Class SMF Selection Ordering Information Horsepower Ratings Maximum Horsepower Heater Elements see page 16-148. 䊳 Field Modification Kits see page 16-79. 䊳 Dimensions see pages 16-99. 䊳 Wiring Diagrams see page 16-129. 䊳 AC Single Phase DC 1-Pole 2-Pole 2-Pole 115–230 1 1 34 277 1 1 — Volts Class SMF Starter in a NEMA Type 1 Enclosure with Pilot Light ⁄ Starter—Class SMF, Single Phase General Purpose Flush Mounting Open Starter with Flush Plate (No Enclosure Provided) Standard Stainless Steel Flush Plate Gray Flush Plate NEMA Type 1 General Purpose Enclosure, Surface Mounting Jumbo Stainless Steel Flush Plate Type Open Type of No. of Catalog List Catalog List Catalog List Catalog Operator Poles Starter Features Number Price $ Number Price $ Number Price $ Number Standard Red Pilot Light Standard Red Pilot Light Standard Red Pilot Light Standard Red Pilot Light 1 Toggle 2 1 Key 2 SMFF01 SMFF01P SMFF02 SMFF02P SMFF03 SMFF03P SMFF04 SMFF04P 43.00 69.00 51.00 77.00 61.00 86.00 69.00 96.00 SMFFF1 48.00 SMFFF1P 72.00 SMFFF2 56.00 SMFFF2P 82.00 SMFFF3 65.00 SMFFF3P 82.00 SMFFF4 72.00 SMFFF4P 100.00 SMFFS1 SMFFS1P SMFFS2 SMFFS2P SMFFS3 SMFFS3P SMFFS4 SMFFS4P 50.00 77.00 61.00 86.00 69.00 96.00 77.00 103.00 — SMFFSJ1P — SMFFSJ2P — SMFFSJ3P — SMFFSJ4P Standard NEMA Type 4 Watertight, Dust-tight Metallic Enclosure with Clear Cover Watertight, Dust-tight Metallic Enclosure NEMA Type 3R, 7 & 9 Div 1 and Div 2 Class I Groups B, C, D & Class II Groups E, F, G Enclosures Oversized List Catalog Price $ Number List Catalog Price $ Number — 90.00 — 100.00 — 107.00 — 117.00 51.00 77.00 61.00 86.00 69.00 96.00 77.00 103.00 SMFFG1 SMFFG1P SMFFG2 SMFFG2P SMFFG3 SMFFG3P SMFFG4 SMFFG4P NEMA Type 3R, 4 & 12 List Catalog Price $ Number SMFFGJ1 61.00 SMFFWN1 SMFFGJ1P 86.00 SMFFWN1P SMFFGJ2 69.00 SMFFWN2 SMFFGJ2P 96.00 SMFFWN2P SMFFGJ3 77.00 SMFFWN3 SMFFGJ3P 103.00 SMFFWN3P SMFFGJ4 86.00 SMFFWN4 SMFFGJ4P 111.00 SMFFWN4P List Catalog Price $ Number 182.00 189.00 249.00 258.00 198.00 207.00 268.00 276.00 List Catalog Price $ Number — — — — — — — — — — — — — — — — List Price $ — — — — — — — — — — — — — — — — Starter With Handle Guard/Lock-Off—Class SMF, Single Phase Standard Red Pilot Light (2) 3⁄4" NPT Outlets (2) 3⁄4" NPT Outlets and Red Pilot Light Standard Red Pilot Light (2) 3⁄4" NPT Outlets (2) 3⁄4" NPT Outlets and Red Pilot Light CONTROL PRODUCTS 16 1 Toggle 2 — — — — — — — — — — — — — — — — — — — — — — — — — — — SMFFG5 61.00 SMFFGJ5 SMFFG5P 86.00 SMFFGJ5P — — — 69.00 — 96.00 — — — — — — SMFFW1 193.00 SMFFR1 211.00 SMFFW1P 262.00 — — SMFFW1H 211.00 SMFFR1H 228.00 — — — — SMFFW1PH 279.00 — — — — — — — — — — — — — — — — SMFFG6 69.00 SMFFGJ6 77.00 — SMFFG6P 98.00 SMFFGJ6P 103.00 — — — — — — — — — SMFFW2 203.00 SMFFR2 219.00 SMFFW2P 272.00 — — SMFFW2H 219.00 SMFFR2H 237.00 — — — SMFFW2PH 289.00 — — — — — — One Starter in Duplex Enclosure—Class SMF, Single Phase NEMA & General Purpose Control General Purpose Flush Mounting Open Starter with Flush Plate - (No Enclosure Provided) Type of Operator Number of Poles Toggle 2 Key 2 Starter Features Standard Red Pilot Light Red Pilot Light Gray Flush Plate For Wall or Cavity Mounting Stainless Steel Flush Plate for Wall or Cavity Mounting NEMA Type 1 General Purpose Enclosure Surface Mounting Catalog Number — — — Catalog Number — — — List Price $ — — — Catalog Number List Price $ SMFFG02 96.00 SMFFG02P 121.00 SMFFG04P 121.00 — SMFFS22P SMFFS44P — 242.00 276.00 SMFFG222 SMFFG222P SMFFG44P List Price $ — — — Replacement Starters Catalog Number — — — List Price $ — — — Two Starters In Duplex Enclosure—Class SMF, Single Phase Toggle 2 Per Starter Key 2 Per Starter Standard Red Pilot Light on Each Starter Red Pilot Light on Each Starter SMFFF222 SMFFF222P SMFFF44P 138.00 233.00 268.00 147.00 242.00 276.00 — — — — — — Starter And “Auto-Off-Hand” SPDT Selector Switch (AC Only)—Class SMF, Single Phase Standard Red Pilot Light Standard Red Pilot Light Red Pilot Light 1 Toggle 2 Key 2 SMFFF71 SMFFF71P SMFFF72 SMFFF72P SMFFF74P 125.00 151.00 133.00 160.00 176.00 — SMFFS71P — SMFFS72P SMFFS74P — 160.00 — 168.00 186.00 SMFFG71 SMFFG71P SMFFG72 SMFFG72P SMFFG74P 133.00 160.00 142.00 168.00 186.00 — — — — — — — — — — SMFFF11 SMFFF11P 182.00 276.00 — — — — SMFFG11 SMFFG11P 189.00 285.00 SMFF01T SMFF01PT 51.00 77.00 Two Speed Starters (AC Only)—Class SMF, Single Phase Mechanical Interlock Mechanical Interlock and (2) Red Pilot Lights Mechanical Interlock, HIGH-OFF-LOW Selector Switch and (2) Red Pilot Lights Mechanical Interlock Mechanical Interlock and (2) Red Pilot Lights Mechanical Interlock, HIGH-OFF-LOW Selector Switch and (2) Red Pilot Lights 1 Toggle 2 One heater element required. Furnished with (1) 3⁄4" NPT Outlet in bottom — — SMFFS101P 285.00 — — SMFF01PT 77.00 SMFFF22 SMFFF22P 198.00 293.00 — — — — SMFFG22 SMFFG22P 207.00 302.00 SMFF02T SMFF02PT 61.00 86.00 — — SMFFS202P 302.00 — — SMFF02PT 86.00 Two heater elements required. Order Open Type starter plus separate For handle guard kit. (reversible for top feed). 16-6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog starters that contain a pilot light, a Red light is standard. For a Green pilot light add ”G” to the end of the catalog number. Discount Schedule NEMA Manual Control Fractional HP Switches, Class MMS, MRS Class MMS, MRS Enclosures Class MMS and MRS motor starting switches provide manual “ON-OFF” control of single or three phase AC motors where overload protection is not required or is provided separately. Compact construction and a 600 volt rating make these switches suitable for a wide range of industrial and commercial uses. Typical applications include small machine tools, pumps, fans, conveyors and many other types of electrical machinery. They can also be used on non-motor loads such as resistance heating applications. Class MMS, MRS, NEMA Type 1 surface mounting enclosures are sheet steel with a thermo-plastic wrap-around cover for convenience in wiring. The NEMA Type 1 enclosure is also available in an oversized version which allows more wiring space. A zinc alloy die casting is used for NEMA Type 4 enclosures. Class MMS Switch in a NEMA Type 1 Enclosure CONTROL PRODUCTS Emergency Off Actuator A toggle operator extender is available for Class MMS, MRS, NEMA Type 1 surface mounted units. The extender has a red vinyl button that provides a fast and easy method for locating and switching the device‘s toggle operator into the OFF position. The Emergency Off Actuator is available in kit form only for field installation. Handle Guard/Lock-Off An optional handle guard on Class MMS, MRS, NEMA Type 1 enclosed switches prevents accidental operation of the toggle operator and also allows the toggle operator to be padlocked in either the “ON” or “OFF” position. This handle guard is available in kit form for field installation on NEMA Type 1 surface and flush mounting enclosures. Standard NEMA Type 4 metallic enclosures include provisions for padlocking the device in the OFF position. 16 Continuous Current Rating MMS & MRS: 30 amperes at 250 volts max, 26.4 amperes at 277 volts, 20 amperes at 600 volts max, 30 amperes resistive at 600 volts max. Two Speed—Class MRS Two speed manual switches may be used with separate winding three phase or single phase AC motors where overload protection is not required or is provided separately. Two switches are employed to give “ON-OFF” control in each speed. Reversing—Class MRS Reversing manual switches provide a compact means of starting, stopping and reversing AC motors where overload protection is not required or is provided separately. They are suitable for use with three phase squirrel cage motors and for single phase motors which can be reversed by reconnecting motor leads. Two switches are used, one to connect the motor forward rotation and one for reverse. Pilot Lights Red or green neon pilot light units are available for flush mounting plates, NEMA Type 1 enclosures, and NEMA Type 4 enclosures. Pilot lights may be either factory or field installed. (For switches that contain a pilot light, a Red light is standard. For a Green pilot light add ”G” to the end of the catalog number.) Terminals Binding head screw type terminals are suitable for #10 or smaller copper wire, and are accessible from the front. All terminals are clearly marked. Mounting Open types without a pilot light fit standard single gang switch boxes, and can be used with any cover plate having a standard toggle cutout. Single-unit flush mounting types, including those with pilot lights, are suitable for wall mounting in a standard switch box or for machine cavity mounting without a box. Operation Available with toggle handle or with removable key type operator to discourage unauthorized operation. General NEMA & General Purpose Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-7 Manual Control Switches, Class MMS, MRS Selection Ordering Information Horsepower Ratings 䊳 Heater Elements not Required. Field Modification Kits see page 16-79. Dimensions see pages 16-99. 䊳 Wiring Diagrams see page 16-129. 䊳 䊳 Device Class MMS Class MRS Reversing Class MMS Two Speed Class MMS Switch in a NEMA Type 1 Enclosure Maximum HP No of Poles Motor Type AC 2 3 2 3 2 3 3 Single Phase 3-Phase Single Phase 3-Phase Single Phase 3-Phase, Constant or Variable Torque 3-Phase, Constant Horsepower 115V 2 2 2 2 2 2 2 DC Ratings 230V 450–575V 90V 115V 230V 2 71/2 2 71/2 2 71/2 71/2 3 10 3 10 3 10 10 2 2 2 2 2 2 2 1 1 1 1 1 1 1 11/2 11/2 11/2 11/2 11/2 11/2 11/2 Switch—Class MMS, Single Phase and 3-Phase General Purpose Flush Mounting Open Switch with Flush Plate (No Enclosure Provided) Standard Jumbo Gray Stainless Stainless Flush Steel Steel Plate Flush Plate Flush Plate Type No Open Type of of Switch Catalog List Catalog Operator Poles Features Number Price $ Number Standard MMSK01 32.00 MMSKF1 Red Pilot Light 75.00 MMSKF1A MMSK01A 115V AC 2 Toggle 3 List Catalog Price $ Number List Catalog Price $ Number 36.00 MMSKS1 40.50 NEMA Type 1 General Purpose Enclosure Surface Mounting with Clear Cover Standard — MMSKG1 List Catalog Price $ Number 40.50 MMSKGJ1 83.00 MMSKSJ1A 97.00 MMSKG1A 83.00 MMSKGJ1A 80.00 MMSKS1B 83.00 MMSKSJ1B 97.00 MMSKG1B 83.00 MMSKGJ1B Standard 86.00 MMSKS2 90.00 — — MMSKG2 Class I Groups B, C & D & Class II Groups E, F, G Enclosures Enclosure Oversized 80.00 MMSKS1A 82.00 MMSKF2 NEMA Type 7 & 9 Watertight, Dust-tight Metallic Enclosurer Metallic Red Pilot Light MMSK01B 75.00 MMSKF1B 230V AC MMSK02 NEMA Type 4 Watertight, Dust-tight List Catalog Price $ Number — NEMA Type 3R, 4 & 12 90.00 MMSKGJ2 List Catalog Price $ Number 49.00 MMSKWN1 List Catalog Price $ Number List Catalog Price $ Number 170.00 MMSKW1 189.00 MMSKR1 207.00 91.00 MMSKWN1A 212.00 MMSKW1A 258.00 — — 91.00 MMSKWN1B 212.00 MMSKW1B 258.00 — — 100.00 MMSKWN2 212.00 MMSKW2 233.00 MMSKR2 254.00 Red Pilot Light 208-240V AC MMSK02B 125.00 MMSKF2B 130.00 MMSKS2B 133.00 MMSKSJ2B 147.00 MMSKG2B 133.00 MMSKGJ2B 142.00 MMSKWN2B 281.00 MMSKW2B 302.00 Red Pilot Light 440-600V AC MMSK02C 125.00 MMSKF2C 130.00 MMSKS2C 133.00 MMSKSJ2C 147.00 MMSKG2C 133.00 MMSKGJ2C 142.00 MMSKWN2C 281.00 MMSKW2C Standard 2 MMSK03 Red Pilot Light MMSK03B 230V AC Key 3 CONTROL PRODUCTS 16 Red Pilot Light MMSK03A 115V AC List Price $ — — — 49.00 MMSKF3 54.00 MMSKS3 187.00 — — — — 91.00 MMSKF3A 97.00 MMSKS3A 101.00 MMSKSJ3A 111.00 MMSKG3A 101.00 MMSKGJ3A 107.00 MMSKWN3A 229.00 — — — — 97.00 MMSKS3B 101.00 MMSKSJ3B 111.00 MMSKG3B 101.00 MMSKGJ3B 107.00 MMSKWN3B 229.00 91.00 MMSKF3B 57.00 — — MMSKG3 57.00 MMSKGJ3 69.00 MMSKWN3 302.00 — — — — — 237.00 — — — — 142.00 MMSKF4B 147.00 MMSKS4B 151.00 MMSKSJ4B 163.00 MMSKG4B 151.00 MMSKGJ4B 160.00 MMSKWN4B 306.00 — — — — 142.00 MMSKF4C 147.00 MMSKS4C 151.00 MMSKSJ4C 163.00 MMSKG4C 151.00 MMSKGJ4C 160.00 MMSKWN4C 306.00 — — — — Standard MMSK04 Red Pilot Light 208–240V AC MMSK04B 127.00 MMSKF4 Red Pilot Light MMSK04C 440–600V AC 103.00 MMSKS4 107.00 — — MMSKG4 107.00 MMSKGJ4 117.00 MMSKWN4 NEMA & General Purpose Control Reversing Switch—Class MRS, Single Phase and 3-Phase Type of Operator Number of Poles Suitable Motor Types Switch Features (Including Mechanical Interlock) 2 Single Phase 3-Lead Repulsion-Induction 3 3-Phase; Also Single Phase Capacitor, Split Phase, or 4-Lead Repulsion-Induction Standard Red Pilot Device—115V AC Red Pilot Device— 230V AC Standard Red Pilot Light—110–120V AC Red Pilot Light—208–220V AC Red Pilot Light—440–600V AC Toggle General Purpose Flush Mounting NEMA Type 1 Open Switch with Flush Plate General Purpose (No Enclosure Provided) Enclosure Surface Mounting Catalog Number List Price $ Catalog Number List Price $ MRSKF11 MRSKF11A MRSKF11B MRSKF22 MRSKF22A MRSKF22B MRSKF22C 163.00 233.00 233.00 258.00 328.00 328.00 328.00 MRSKG11 MRSKG11A MRSKG11B MRSKG22 MRSKG22A MRSKG22B MRSKG22C 172.00 242.00 242.00 268.00 336.00 336.00 336.00 Replacement Switch Class MRS Catalog Number List Price $ MRSK01T MRSK01AT MRSK01BT MRSK02T MRSK02AT MRSK02BT MRSK02CT 40.50 83.00 83.00 90.00 133.00 133.00 133.00 Two Speed Switch—Class MMS, Single Phase and 3-Phase Type of Operator Suitable Motor Types Switch Features (Including Mechanical Interlock) 2 Single Phase Two Winding (3-Lead) 3 3-Phase Separate Winding (Wye-Connected) Standard (2) Red Pilot Devices—115V AC (2) Red Pilot Devices—230V AC Standard (2) Red Pilot Lights—208–240V AC (2) Red Pilot Lights—440–600V AC Number of Poles Toggle Manual switches do not include overloads. Furnished with (1) 3/4" NPT outlet in bottom (reversible for top feed). In order to obtain a 3⁄4" NPT outlet in top and bottom, add suffix letter “H” to type number and add $16 to List Price. 16-8 General Purpose Flush Mounting NEMA Type 1 Open Switch with Flush Plate General Purpose (No Enclosure Provided) Enclosure Surface Mounting Catalog Number List Price $ Catalog Number List Price $ MMSKF11 MMSKF11A MMSKF11B MMSKF22 MMSKF22B MMSKF22C 163.00 302.00 302.00 258.00 396.00 396.00 Do not use as replacement interiors for NEMA Type 4 metallic enclosures. For replacement unit, order Type MMSK01 or MMSK02 and separate pilot light kit. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MMSKG11 MMSKG11A MMSKG11B MMSKG22 MMSKG22B MMSKG22C 172.00 310.00 310.00 268.00 405.00 405.00 Replacement Switch Class MRS Catalog Number List Price $ MRSK01T MRSK01AT MRSK01BT MRSK02T MRSK02BT MRSK02CT 40.50 83.00 83.00 90.00 133.00 133.00 For switches that contain a pilot light, a Red light is standard. For a Green pilot light add ”G” to the end of the catalog number. Discount Schedule NEMA Manual Control Starters and Switches, Class 11 - 3RV Class 11 - 3RV Class 11 across the line manual starters and switches provide control for machinery where remote start stop control is not required. Class 11 - 3RV manual starters are used for single and poly-phase motors up to 20HP @ 575V. Starters have bimetallic heater elements to provide class 10 overcurrent protection. Each starter has a fourth bimetallic strip that reacts only to the ambient temperature inside the control panel. This ambient compensation helps prevent the starter from nuisance tripping when the panel temperature is higher than the ambient temperature of the motor. A built-in differential trip bar causes the starter to trip faster on a phase loss condition to help reduce motor damage. Magnetic trip elements in each starter take the device off line when it senses current of 13 times the maximum FLA dial setting. Class 11 - 3RV switches provide control for inherently protected motors. Typical applications include metal and woodworking machinery, grinders, power saws, conveyors, fans, pumps, General blowers, textile and packaging machinery, and paper cutters. Each switch is provided with magnetic trip elements which take the device off line when it senses current of 13 times the maximum switch rating. Class 11 - 3RV manual starters can be used as Type E self-protected manual combination starters (up to 22 amps) per UL508 or as components in Group Installation per NEC 430.53. When using the Class 11 - 3RV as a manual combination starter upstream protection is not required. Class 11 - 3RV controllers are available with low voltage protection which will automatically open the power poles when the voltage drops or the power is interrupted. Controllers with the LVP option provide the OSHA requirements for protecting personnel from potential injury caused by the automatic start-up of machinery following a voltage drop or power interruption when low voltage protection is specified. Class 11 - 3RV is available as Open style, or in NEMA 1, NEMA 7 & 9 or NEMA 7 & 9 / 3 & 4 enclosures. Standard Features include: ▪ ON/OFF rotary handle with lockout and visible trip indication ▪ Adjustment dial for setting to motor FLA (Starters only) ▪ Low Voltage Protection (LVP) Option ▪ Short Circuit trip at 13 times the maximum setting of the FLA dial or rated current ▪ Ambient compensated up to 140°F ▪ Phase loss sensitivity ▪ Test trip function ▪ LVP Option Meets OSHA Requirements ▪ UL Listed ▪ CSA Certified 16 CONTROL PRODUCTS NEMA & General Purpose Control OPEN TYPE Starter NEMA 1 General Purpose NEMA 7 & 9 Div 1 & Div 2 Class I Group C & D Class II Group E, F & G NEMA 3 & 4, NEMA 7 & 9 Div 1 & Div 2 Class I Group C & D Class II Group E, F & G Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-9 Manual Control Starters and Switches, Class 11 - 3RV Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 Low Voltage Protection Coil Table No heaters required. Field modification kits see page 16-79. Dimensions see page 16-101. Wiring Diagrams see page 16-129. For applications requiring a low voltage protection coil see table at right. 60 Hz Voltage Letter 120V 208V 240V 460V *F *D *G *H *Add corresponding letter to end of base Class 11 catalog number for low voltage protection coil. $96.00 list adder. Note: The LVP option for Open type 3RV is available from the factory, please order separately from the field modification kits on page 16-80. Class 11 Manual Motor Starter The coil voltage should correspond with the line voltage. Manual Starter—Class 11 - 3RV NEMA & General Purpose Control CONTROL PRODUCTS 16 FLA Adjustment Range 0.11-0.16 0.14-0.2 0.18-0.25 0.22-0.32 0.28-0.4 0.35-0.5 0.45-0.63 0.55-0.8 0.7-1 0.9-1.25 1.1-1.6 1.4-2 1.8-2.5 2.2-3.2 2.8-4 3.5-5 4.5-6.3 5.5-8 7-10 9-12.5 11-16 14-20 17-22 20-25 Max HP Enclosure Single Phase 3-Phase Open Type HP Ratings HP Ratings 115V 230V 200V 230V 460V 575V Catalog Number — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1 1 1 1 3 3 1 1 1⁄2 2 3 3 5 5 7 1⁄2 7 1⁄2 1 1 1 1⁄2 2 3 3 5 7 1⁄2 7 1⁄2 7 1⁄2 1 1 1⁄2 1 1⁄2 2 3 5 5 7 1⁄2 7 1⁄2 10 15 15 15 1 1 1⁄2 1 1⁄2 2 3 3 5 5 10 10 15 20 20 20 3RV1021-0AA10 3RV1021-0BA10 3RV1021-0CA10 3RV1021-0DA10 3RV1021-0EA10 3RV1021-0FA10 3RV1021-0GA10 3RV1021-0HA10 3RV1021-0JA10 3RV1021-0KA10 3RV1021-1AA10 3RV1021-1BA10 3RV1021-1CA10 3RV1021-1DA10 3RV1021-1EA10 3RV1021-1FA10 3RV1021-1GA10 3RV1021-1HA10 3RV1021-1JA10 3RV1021-1KA10 3RV1021-4AA10 3RV1021-4BA10 3RV1021-4CA10 3RV1021-4DA10 1 ⁄10 1 ⁄8 1 ⁄6 1 ⁄4 1 ⁄3 1 ⁄2 1 ⁄2 1 1 1⁄2 2 2 1 ⁄10 ⁄8 1 ⁄6 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 1 1 1⁄2 2 3 3 3 5 ⁄2 ⁄4 3 ⁄4 ⁄2 ⁄4 ⁄2 3 ⁄4 3 ⁄4 1 ⁄2 ⁄2 3 ⁄4 NEMA 1 NEMA 7 & 9 NEMA 3 & 4, NEMA 7 & 9 General Purpose Class I Groups C & D Class II Groups E, F & G Watertight (Outdoor use) Class I Groups C & D Class II Groups E, F & G List Price $ Catalog Number List Price $. Catalog Number List Price $ 145.00 145.00 145.00 145.00 145.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 160.00 191.00 191.00 191.00 191.00 191.00 11AD3B 11BD3B 11CD3B 11DD3B 11ED3B 11FD3B 11GD3B 11HD3B 11JD3B 11KD3B 11LD3B 11MD3B 11ND3B 11PD3B 11QD3B 11RD3B 11SD3B 11TD3B 11UD3B 11VD3B 11WD3B 11XD3B 11YD3B 11ZD3B 160.00 160.00 160.00 160.00 160.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 189.00 233.00 233.00 233.00 233.00 233.00 11AD3H 11BD3H 11CD3H 11DD3H 11ED3H 11FD3H 11GD3H 11HD3H 11JD3H 11KD3H 11LD3H 11MD3H 11ND3H 11PD3H 11QD3H 11RD3H 11SD3H 11TD3H 11UD3H 11VD3H 11WD3H 11XD3H 11YD3H 11ZD3H 555.00 555.00 555.00 555.00 555.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 586.00 689.00 689.00 689.00 689.00 689.00 Catalog Number List Price $ 11AD3W 11BD3W 11CD3W 11DD3W 11ED3W 11FD3W 11GD3W 11HD3W 11JD3W 11KD3W 11LD3W 11MD3W 11ND3W 11PD3W 11QD3W 11RD3W 11SD3W 11TD3W 11UD3W 11VD3W 11WD3W 11XD3W 11YD3W 11ZD3W 652.00 652.00 652.00 652.00 652.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 682.00 785.00 785.00 785.00 785.00 785.00 Manual Switch—Class 11 - 3RV Rated Current 1 5 10 20 25 Max HP Enclosure Single Phase 3-Phase Open Type HP Ratings HP Ratings 115V 230V 200V 230V — — 1 6 1 2 2 1 1⁄2 3 5 — 1 3 5 7 1⁄2 — 1 3 7 1⁄2 7 1⁄2 ⁄ 1 ⁄2 1 1⁄2 Instantaneous ⁄ 460V 575V Catalog Number 1 2 1 2 3 7 1⁄2 15 15 3 10 20 20 3RV1321-0JC10 3RV1321-1FC10 3RV1321-1JC10 3RV1321-4BC10 3RV1321-4DC10 ⁄ Magnetic Trip will occur at 13 times the maximum FLA dial setting or rated switch current. Discount Code: IEC. 16-10 ⁄ NEMA 1 NEMA 7 & 9 NEMA 3 & 4, NEMA 7 & 9 General Purpose Class I Groups C & D Class II Groups E, F & G Watertight Class I Groups C & D Class II Groups E, F & G List Price $. Catalog Number List Price $ Catalog Number List Price $ 154.00 154.00 154.00 185.00 185.00 111D3B 112D3B 113D3B 114D3B 115D3B Shaded Ratings apply for Manual Motor Controllers Only! These Ratings do not apply as UL Listed Manual Combination Starters. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 189.00 189.00 189.00 233.00 233.00 111D3H 112D3H 113D3H 114D3H 115D3H 586.00 586.00 586.00 689.00 689.00 Catalog Number List Price $ 111D3W 112D3W 113D3W 114D3W 115D3W 682.00 682.00 682.00 785.00 785.00 Add 1 to the end of the catalog number for 1/2 inch drain hole with plug. Add $53. to the list price. Drain fitting not supplied, order separately XDB-2. Discount Schedule NEMA Heavy Duty Control Catalog Numbering System General ESP 100® Current Range Three Phase A B D E F Model G H P — Thermal size 00– 4, J Solid state sizes 5 K &6 L S — ESP100 size 0–31⁄2 M T — ESP100 size 4 U H — ESP100 size 7 & 8 X Y Z Enclosure Size Class 17 — Combination Starter Size (Non Fusible, Fusible) 18 — Combination Starter (Circuit Breaker) 25 — Reversing Combination Starter (Non Fusible, Fusible) 26 — Reversing Combination Starter (Circuit Breaker) C D E F G H I J L M N P — — — — — — — — — — — — 0 1 13⁄4 2 21⁄2 3 31⁄2 4 5 6 7 8 — — — — — — — — — — — — — — — .25–1 .75–3 2.5–10 9–18 13–27 20–40 22–45 30–60 45–90 57–115 67–135 55–250 200–540 420–820 420–1220 Breaker HP Code Horsepower Rating 200, 230, 460, 575 A B C D E F G H J K L M N P R 92 — Standard Width 82 — Extra Wide Enclosure Type B F H N W — — — — — NEMA NEMA NEMA NEMA NEMA — — — — — — — — — — — — — — — 1 ⁄2, 1⁄2,1, 1 1, 1, 3, 3 3, 3, 5, 5 3, 3, 71⁄2, 71⁄2 71⁄2, 71⁄2, 10, 10 —, —, 15, 15 10, 10, —, — 71⁄2, 10, 20, 20 10, 15, 25, 25 —, —, 30, 30 15, 20, —, — —, —, 30, 30 25, 30, 50, 50 30, 40, 75, 75 40, 50, 100, 100 1 4X Fiberglass 7/9/3/4, bolted (Class 18 & 26 only) 12 Field convertible to 3/3R/4 4/4X Stainless Steel Class Pilot Control Circuit 14 — Across the Line NEMA Size 36 — Non C — D — E — F — G— H — I — J — L — M— N— P — Combination Reduced Voltage Starter 37 — Combination Reduced Voltage Starter Single Model P — Thermal size 00–31⁄2, G S T H — — — — Solid state sizes 5 & 6 Thermal size 4 ESP100 size 00–31⁄2 ESP100 size 4 ESP100 size 7 & 8 Model 0 1 13⁄4 2 21⁄2 3 31⁄2 4 5 6 7 8 S — ESP100 size 0–4 T — ESP100 size 5–6 H — ESP100 size 7 & 8 phase ESP100 available on Class 14 Starters only. used on Class 17, 25 or with ESP100 versions. ESP 100® Current Range 110V/190–220V@50Hz C — 220–240V/440–480V@60Hz 190–220V/380–440V@50Hz D — 200–208V@60Hz .25–1 E — 550–600V@60Hz .75–3 550V@50Hz 2.5–10 F — 120V@60Hz 9–18 Power Poles/Enclosure Size 110V@50Hz 13–27 G — 220–240V@60Hz 20–40 1 — 2 power poles,1-phase 190–220V@50Hz 22–45 3 — 3 power poles, 3-phase H — 440–480V@60Hz 30–60 82 — 3 power poles, 3-phase, 380–440V@50Hz 45–90 extra wide enclosure J — 24V@60Hz 57–115 24V@50Hz 67–135 L — 277V@60Hz 55–250 240V@50Hz 200–540 Enclosure Type 420–820 420–1220 A — Open B — NEMA 1 Single Phase F — NEMA 4X Fiberglass A — .25–1 H — NEMA 7/9/3/4 bolted B — .75–3 0 — NEMA 12 Field convertible to 3/3R/4 D — 2.5–10 W — NEMA 4/4X Stainless Steel E — 5–16 A B D E F G H J K L M U X Y Z — — — — — — — — — — — — — — — Type Line Volts Enclosure Type T — Auto XFMR P — Part Wind. 0 — Wye Delta 2 3 4 5 6 A — Open B — NEMA 1 W — NEMA 4/4X Open Trans. C — Wye Delta Closed Trans. Not available on sizes For Class 37 only. 5–8. — — — — — 230 380 460 575 200/208 Coil D E F Stainless Steel G 0 — NEMA 12 H L Disconnect Type D — Non Fused Disc. F — Fusible Disc. P — MCP Position used for ESP100 only. Not available on sizes 7 and 8. Not Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-11 NEMA & General Purpose Control Class 00 0 1 13⁄4 & 1P 2 21⁄2 3 31⁄2 4 5 6 7 8 A — 110–120V/220–240V@60Hz CONTROL PRODUCTS — — — — — — — — — — — — — 3-wire control (NO aux. contact incl.) Three Phase Size B C D E F G H I J L M N P 2 — suitable for ESP 100 Current Range Coil 16 Motor Starter 22 — Reversing NEMA Motor Starter 40 — Across the Line NEMA Magnetic Contactor 43 — Reversing NEMA Magnetic Contactor ® Heavy Duty Starters Features and Benefits General NEMA starters are ideal for applications requiring dependability and durability. Typical applications include use with machine tools, air conditioning equipment, material handling equipment, compressors, hoists and various production and industrial equipment as well as in demanding automotive applications. Starters are available as an open type or in NEMA 1, 12/3/3R, 4 (painted), 4/4X (stainless), 4X (fiberglass), and 7 & 9 enclosures. are available to meet particular application requirements ▪ Normally opened or normally closed auxiliary power pole kits are available for Sizes 00 through 13⁄4 ▪ Transformers can be ordered as either factory or field modifications. In some cases these may require a larger enclosure ▪ A full line of replacement parts are available including contact kits, coils, and overload relays Gravity Dropout For added reliability, the gravity dropout of the armature and contacts is assisted by stainless steel springs which help provide quick, precise opening of the contacts. Standard Features CONTROL PRODUCTS 16 Size 00–4 magnetic starters include the following standard features: ▪ ▪ ▪ ▪ Rugged Industrial Design ▪ ▪ ▪ ▪ ▪ ▪ Wide Range of Accessories Half Sizes for Cost and Space Savings Dual Voltage, Dual Frequency Coils Solid State or Ambient Compensated Bimetal Overload Protection Terminal Design Control terminals are self-rising pressure type. Gravity Dropout Large Silver Cadmium Contacts Dual Voltage/Frequency Coil Overload Test Feature Straight Thru Wiring Application NEMA & General Purpose Control 45 Degree, Wedge Action Contacts The 45 degree, wedge action contacts reduce tracking and provide faster arc quenching. The resulting self-cleaning and reduced contact bounce mean cooler operation and longer life for the large silver cadmium oxide contacts. Molded Coil Magnetic coils are carefully wound and then sealed in epoxy. Encapsulation helps seal out moisture, promotes heat transfer and resists electrical, mechanical and thermal stresses. Easy Coil Access Heavy Duty starters are designed for across the line starting of single phase and polyphase motors. These controls are available in NEMA Sizes 00 through 8. In addition to the usual NEMA Starter Sizes, Siemens offers three exclusive Half Sizes; 13⁄4, 21⁄2 and 31⁄2. These integral sizes offer the same rugged, industrial construction as our NEMA Sizes and ensure efficient operating performance. Half Sizes provide a real cost savings by cutting down on over capacity when NEMA Sizes exceed the motor ratings. All Siemens Heavy Duty controls, including our popular Half Sizes comply with applicable NEMA and UL tests. All starters are supplied with a NO holding interlock that in conjunction with an appropriate pilot device will provide low voltage protection or release. 16-12 Part No 49D70084 Starters are available with dual voltage, dual frequency coils. They are designed to operate on either 50 or 60 Hertz. Molded Stationary Contact Block Thermoset materials resist arc tracking and the stresses of heat and severe impact. Field Modification Kits All starters can be modified in the field with a complete range of accessories. These include pushbuttons, selector switches, pilot lights, auxiliary contacts and surge suppressors. Auxiliary Equipment ▪ NEMA starters are available with built-in START-STOP push buttons for 3-wire control or a HAND-OFF-AUTO selector switch for 2-wire control ▪ Field modifications such as auxiliary contacts, pilot lights, push buttons, selector switches, and fuse blocks Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Siemens Sizes 00–13⁄4 have as standard, universal mounting which fits the following: Cutler Hammer—Citation Series —Freedom Series GE —300 Line Square D —Type S The Starter with its existing backplate mounts onto the piggyback mounting plate and is secured in place with three mounting screws. The piggyback mounting plate fits the following: Allen-Bradley —Bulletin 509 —Bulletin 709 Westinghouse —Series A200 Size 5 & 6 Starters Additional Features ▪ Solid State Overload (3RB type) Standard ▪ Latest technology in arc quenching to extend contactor life ▪ Wide variety of enclosures in all starter configurations Size 7 & 8 Starters Additional Features ▪ New Compact Design ▪ Can be mounted in any position ▪ Same coil voltage is AC or DC Heavy Duty Starters Features and Benefits Selection Half Size Starters Half-Size starters feature all the rugged performance characteristics of our NEMA rated starter sizes, but are fractionally sized to more closely match your exact motor rating. As a result, significant economic savings are made possible without sacrificing the reliability you expect from a heavy duty starter. ESP100® Solid State Starter ESP100® starters combine the rugged characteristics of a NEMA rated contactor with a solid state overload that provides phase loss protection. It offers the industrial user greater protection and added life for motors in heavy duty applications. The inherent benefits of the ESP100® ultimately result in a cost savings to the user. ESP100® Solid State Overload Relays These standard features of the ESP100® provide Extra Starter Performance. These additional starter sizes have the reserve capacity to handle occasional plugging and jogging applications without derating. Superior operating performance in heavy duty applications is assured by the large current carrying parts, not by derating the device. Typical Solid-State Overload Adjustment Dial Markings Each overload is precisely calibrated and labels are individually laser printed and then custom applied for each particular calibration. Exclusive “half-sizes” save potentially hundreds, even thousands of dollars per project. Using the table below, simply match the specific size starter to the horsepower rating of your motor. Every half-size starter saves you money—up to 31%. All “half-sizes” comply to applicable NEMA and UL standards. Savings for Siemens “Half-Size” Starters in NEMA 1 Enclosures, FVNR Motor Size 230V 7 1⁄2 460V Starter Size Half Size List Price $ “Half-Size” Savings Over Next Full Size 1 — 393. — 15 — 13⁄4 521. 31% 15 25 2 — 737. — 20 30 — 21⁄2 969. 20% 30 50 3 — 1202. — 40 75 — 31⁄2 2321. 13% 50 100 4 — 2666. — Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEMA & General Purpose Control 10 10 CONTROL PRODUCTS Discount Schedule NEMA Figure 1 16 ▪ True phase loss protection; trips within 3 seconds ▪ High accuracy trip curves; ± 2% repeat trip accuracy ▪ Ease of use. Mount, wire, and set FLA ▪ Overload is self protected against short circuits ▪ Overload is self powered and requires no hard wiring or separate power source ▪ Heaterless construction minimizes energy costs and the costs of cabinet ventilation or cooling ▪ Class 20 protection is standard. Class 10 and 30 protection are available ▪ Provides motor protection for 50/60 Hertz ESP100® FLA Adjustment Dial—Set the adjustment dial on the overload to the FLA of the motor. 16-13 Heavy Duty Motor Starters Solid State Overload with Manual Reset, Class 14 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see pages 16-79. Factory Modifications see pages 16-94. Dimensions see pages 16-102 open and 16-115 enclosed. Wiring Diagrams see page 16-130. Replacement Parts see pages 16-155. Shipped as standard Class 20. For Class 10 or Class 30 see page 16-96. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure Open Type NEMA 1 Standard Auxiliary Contacts General Purpose NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight NEMA 3 & 4 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Corrosion Resistant 316 Stainless Steel (optional) 200 Volts 230 Volts 460 Volts 575 Volts NEMA Half Size Size Overload Amp Catalog Range Number 1 1 1 1 00 00 00 0 0 0 0 1 1 1 1 1 — — 2 2 — — 3 3 — 4 5 6 7 8 0.25–1 0.75–3 2.5–10 0.25–1 0.75–3 2.5–10 9–18 0.25–1 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 55 - 250 160–540 420–820 420–1220 ⁄6 ⁄2 11⁄2 1 ⁄6 1 ⁄2 2 3 1 ⁄6 1 ⁄2 2 3 71⁄2 — 10 — 10 — 15 — 25 30 40 75 150 — — NEMA & General Purpose Control CONTROL PRODUCTS 16 1 ⁄6 ⁄4 11⁄2 1 ⁄6 3 ⁄4 2 3 1 ⁄6 3 ⁄4 2 3 71⁄2 — 10 — 15 — 20 — 30 40 50 100 200 300 450 ⁄3 11⁄2 2 1 ⁄3 11⁄2 5 — 1 ⁄3 11⁄2 5 10 — 15 — 15 25 30 — 30 50 75 100 200 400 600 900 3 ⁄2 2 — 1 ⁄2 2 5 — 1 ⁄2 2 5 10 — 15 — 20 25 30 — 40 50 75 100 200 400 600 900 — — — — — — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — — — — — List Catalog Price $ Number 14BSA32A* 272.00 14BSB32A* 272.00 14BSD32A* 272.00 14CSA32A* 332.00 14CSB32A* 332.00 14CSD32A* 332.00 14CSE32A* 332.00 14DSA32A* 375.00 14DSB32A* 375.00 14DSD32A* 375.00 14DSE32A* 375.00 14DSF32A* 375.00 14ESF32A* 504.00 14ESG32A* 504.00 14FSF32A* 651.00 14FSH32A* 651.00 14GSH32A* 840.00 14GSJ32A* 840.00 14HSJ32A* 1030.00 14HSK32A* 1030.00 14ISL32A* 1960.00 14JTM32A* 2305.00 14LPU32A* 5573.00 14MPX32A* 13198.00 14NHY32A* 19547.00 14PHZ32A* 29223.00 14BSA32B* 14BSB32B* 14BSD32B* 14CSA32B* 14CSB32B* 14CSD32B* 14CSE32B* 14DSA32B* 14DSB32B* 14DSD32B* 14DSE32B* 14DSF32B* 14ESF32B* 14ESG32B* 14FSF32B* 14FSH32B* 14GSH32B* 14GSJ32B* 14HSJ32B* 14HSK32B* 14ISL32B* 14JTM32B* 14LPU32B* 14MPX32B* 14NHY32B* 14PHZ32B* Div 1 and Div 2 Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use List Catalog Price $ Number List Catalog Price $ Number List Catalog Price $ Number 289.00 289.00 289.00 349.00 349.00 349.00 349.00 393.00 393.00 393.00 393.00 393.00 521.00 521.00 737.00 737.00 969.00 969.00 1202.00 1202.00 2322.00 2666.00 6238.00 17507.00 23855.00 33530.00 — — — 651.00 651.00 651.00 651.00 702.00 702.00 702.00 702.00 702.00 831.00 831.00 1357.00 1357.00 1719.00 1719.00 2081.00 2081.00 3821.00 4165.00 8133.00 21814.00 28162.00 37837.00 — — — 716.00 716.00 716.00 716.00 773.00 773.00 773.00 773.00 773.00 914.00 914.00 1492.00 1492.00 1891.00 1891.00 2289.00 2289.00 4203.00 4582.00 — — — — Use Size 0 Use Size 0 Use Size 0 14CSA32W* 14CSB32W* 14CSD32W* 14CSE32W* 14DSA32W* 14DSB32W* 14DSD32W* 14DSE32W* 14DSF32W* 14ESF32W* 14ESG32W* 14FSF32W* 14FSH32W* 14GSH32W* 14GSJ32W* 14HSJ32W* 14HSK32W* 14ISL32W* 14JTM32W* 14LPU32E* 14MPX32E* 14NHY32E* 14PHZ32E* Use Size 0 Use Size 0 Use Size 0 14CSA32F* 14CSB32F* 14CSD32F* 14CSE32F* 14DSA32F* 14DSB32F* 14DSD32F* 14DSE32F* 14DSF32F* 14ESF32F* 14ESG32F* 14FSF32F* 14FSH32F* 14GSH32F* 14GSJ32F* 14HSJ32F* 14HSK32F* 14ISL32F* 14JTM32F* — — — — NEMA 12 NEMA 3/3R List Catalog Price$ Number Use Size 0 — Use Size 0 — Use Size 0 — 14CSA32H* 1434.00 14CSB32H* 1434.00 14CSD32H* 1434.00 14CSE32H* 1434.00 14DSA32H* 1477.00 14DSB32H* 1477.00 14DSD32H* 1477.00 14DSE32H* 1477.00 14DSF32H* 1477.00 14ESF32H* 1606.00 14ESG32H* 1606.00 14FSF32H* 2029.00 14FSH32H* 2029.00 14GSH32H* 2528.00 14GSJ32H* 2528.00 14HSJ32H* 3627.00 14HSK32H* 3627.00 14ISL32H* 4519.00 14JTM32H* 4864.00 14LPU32H* 11269.00 — — — — — — List Price$ Use Size 0 — Use Size 0 — Use Size 0 — 14CSA320* 452.00 14CSB320* 452.00 14CSD320* 452.00 14CSE320* 452.00 14DSA320* 496.00 14DSB320* 496.00 14DSD320* 496.00 14DSE320* 496.00 14DSF320* 496.00 14ESF320* 625.00 14ESG320* 625.00 14FSF320* 926.00 14FSH320* 926.00 14GSH320* 1176.00 14GSJ320* 1176.00 14HSJ320* 1426.00 14HSK320* 1426.00 14ISL320* 3063.00 14JTM320* 3407.00 14LPU320* 8133.00 14MPX320* 19832.00 14NHY320* 26181.00 14PHZ320* 35855.00 Open Type & Standard Width Enclosure, Single Phase, 2-Pole Max Hp Enclosure Open Type NEMA 1 General Purpose 115 Volts 208/230 Volts NEMA Size Overload Amp Range Catalog Number 1 1 0 0 0 1 1 1 0.75–3 2.5–10 5.0–16 0.75–3 2.5–10 5.0–16 14CSB12A* 14CSD12A* 14CSE12A* 14DSB12A* 14DSD12A* 14DSE12A* ⁄8 ⁄4 1 1 ⁄8 1 ⁄4 1 1 ⁄4 ⁄2 2 1 ⁄4 1 ⁄2 2 1 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. For higher Hp single phase motors, use 3-phase starters, wire and set per diagram on page 16-130. 16-14 List Catalog Price $ Number 276.00 276.00 276.00 319.00 319.00 319.00 14CSB12B* 14CSD12B* 14CSE12B* 14DSB12B* 14DSD12B* 14DSE12B* NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight Watertight, Dust-tight NEMA 3 & 4 NEMA 12 NEMA 3/3R Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Industrial Use Weatherproof Corrosion Resistant List Catalog Price $ Number List Catalog Price $ Number 293.00 293.00 293.00 336.00 336.00 336.00 595.00 595.00 595.00 647.00 647.00 647.00 14CSB12W* 14CSD12W* 14CSE12W* 14DSB12W* 14DSD12W* 14DSE12W* 14CSB12F* 14CSD12F* 14CSE12F* 14DSB12F* 14DSD12F* 14DSE12F* Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use List Catalog Price $ Number 654.00 654.00 654.00 711.00 711.00 711.00 14CSB12H* 14CSD12H* 14CSE12H* 14DSB12H* 14DSD12H* 14DSE12H* List Catalog Price $ Number List Price$ 1379.00 1379.00 1379.00 1422.00 1422.00 1422.00 396.00 396.00 396.00 440.00 440.00 440.00 14CSB120* 14CSD120* 14CSE120* 14DSB120* 14DSD120* 14DSE120* Dual voltage coils not available in size 5–8 starters. For conduit hubs and conversion instructions, see page F 16-87. Coils D, F, or G will be wired for incoming voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. Enclosure is NEMA Type 4 (painted steel). Only available F coil100-250V AC 50/60Hz, or DC Standard Auxiliary Contacts, Same as Contactors, Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog coil 100-250V AC 50/60Hz, or DC, H coil 150-500V AC 50/60Hz, or DC refer to page 16-44. 316 Stainless Steel option see page 16-98. For Discount Schedule NEMA Heavy Duty Motor Starters Solid State Overload with Manual Reset, Class 14 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-115. Wiring Diagrams see page 16-130. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. NEMA 1 Extra Wide Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 1 NEMA 4/4X Stainless General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 575 Volts NEMA Size Half Size Overload Amp Range Catalog No 1 1 1 1 00 00 00 0 0 0 0 1 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 0.25–1 0.75–3 2.5–10 0.25–1 0.75–3 2.5–10 9–18 0.25–1 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 ⁄6 1 ⁄2 11⁄2 1 ⁄6 1 ⁄2 2 3 1 ⁄6 1 ⁄2 2 3 71⁄2 — 10 — 10 — 15 — 25 30 40 ⁄6 3 ⁄4 11⁄2 1 ⁄6 3 ⁄4 2 3 1 ⁄6 3 ⁄4 2 3 71⁄2 — 10 — 15 — 20 — 30 40 50 ⁄3 11⁄2 2 1 ⁄3 11⁄2 5 — 1 ⁄3 11⁄2 5 10 — 15 — 15 25 30 — 30 50 75 100 ⁄2 2 — 1 ⁄2 2 5 — 1 ⁄2 2 5 10 — 15 — 20 25 30 — 40 50 75 100 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. For higher Hp single phase motors, use 3-phase starters, wire and set per diagram on page 16-130. Discount Schedule NEMA 14BSA82B* 14BSB82B* 14BSD82B* 14CSA82B* 14CSB82B* 14CSD82B* 14CSE82B* 14DSA82B* 14DSB82B* 14DSD82B* 14DSE82B* 14DSF82B* 14ESF82B* 14ESG82B* 14FSF82B* 14FSH82B* 14GSH82B* 14GSJ82B* 14HSJ82B* 14HSK82B* 14ISL82B* 14JTM82B* To List Price $ Catalog No List Price$ Catalog No List Price $ Catalog No List Price$ 506.00 506.00 506.00 567.00 567.00 567.00 567.00 609.00 609.00 609.00 609.00 609.00 739.00 739.00 885.00 885.00 1074.00 1074.00 1391.00 1391.00 2409.00 2752.00 Use Size 0 Use Size 0 Use Size 0 14CSA82W* 14CSB82W* 14CSD82W* 14CSE82W* 14DSA82W* 14DSB82W* 14DSD82W* 14DSE82W* 14DSF82W* 14ESF82W* 14ESG82W* 14FSF82W* 14FSH82W* 14GSH82W* 14GSJ82W* 14HSJ82W* 14HSK82W* 14ISL82W* 14JTM82W* — — — 961.00 961.00 961.00 961.00 1064.00 1064.00 1064.00 1064.00 1064.00 1193.00 1193.00 1951.00 1951.00 2140.00 2140.00 3821.00 3821.00 4751.00 5096.00 — — — 14CSA82H* 14CSB82H* 14CSD82H* 14CSE82H* 14DSA82H* 14DSB82H* 14DSD82H* 14DSE82H* 14DSF82H* 14ESF82H* 14ESG82H* 14FSF82H* 14FSH82H* 14GSH82H* 14GSJ82H* 14HSJ82H* 14HSK82H* 14ISL82H* 14JTM82H* — — — 2196.00 2196.00 2196.00 2196.00 2264.00 2264.00 2264.00 2264.00 2264.00 2393.00 2393.00 3479.00 3479.00 4314.00 4314.00 5483.00 5483.00 9048.00 9368.00 Use Size 0 Use Size 0 Use Size 0 14CSA820* 14CSB820* 14CSD820* 14CSE820* 14DSA820* 14DSB820* 14DSD820* 14DSE820* 14DSF820* 14ESF820* 14ESG820* 14FSF820* 14FSH820* 14GSH820* 14GSJ820* 14HSJ820* 14HSK820* 14ISL820* 14JTM820* — — — 625.00 625.00 625.00 625.00 668.00 668.00 668.00 668.00 668.00 797.00 797.00 1254.00 1254.00 1443.00 1443.00 2356.00 2356.00 3286.00 3631.00 receive a single phase starter in an extra wide enclosure, order the enclosure kit from pg 16-96 and the open style starter from page 16-14 or 16-16 as separate items. For conduit hubs and conversion instructions, see page 16-87. For 316 Stainless Steel option see page 16-97. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-15 NEMA & General Purpose Control 460 Volts CONTROL PRODUCTS 230 Volts NEMA 12 NEMA 3/3R Industrial Use Weatherproof 16 200 Volts NEMA 7 & 9 NEMA 3 & 4 Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G, Class III Bolted Enclosures Indoor/Outdoor Use Heavy Duty Motor Starters Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 14 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. Single phase starters require 1 heater element. 3-phase starters require 3 heater elements. Field Modification Kits page 16-79. Factory Modifications page 16-94. Dimensions see page 16-103 open and 16-115 enclosed. Wiring Diagrams see page 16-130. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole NEMA & General Purpose Control CONTROL PRODUCTS 16 Max Hp Enclosure 200 Volts 230 Volts 460 Volts 575 Volts Contactor Amp NEMA Half Rating Size Size 1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 2 5 10 15 25 30 50 75 100 2 5 10 15 25 30 50 75 100 9 18 27 40 45 60 90 115 135 00 0 1 — 2 — 3 — 4 — — — 13⁄4 — 21⁄2 — 31⁄2 — Open Type NEMA 1 Standard Auxiliary Contacts General Purpose NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight NEMA 3 & 4 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel NEMA 12 NEMA 3/3R Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Corrosion Resistant Industrial Use Weatherproof Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ 14BP32A*81 233.00 14BP32B*81 14CP32A*81 293.00 14CP32B*81 14DP32A*81 336.00 14DP32B*81 14EP32A*81 465.00 14EP32B*81 14FP32A*81 612.00 14FP32B*81 14GP32A*81 801.00 14GP32B*81 14HP32A*81 991.00 14HP32B*81 14IP32A*81 1922.00 14IP32B*81 14JG32A*81 2266.00 14JG32B*81 249.00 310.00 354.00 482.00 698.00 930.00 1163.00 2284.00 2628.00 Use Size 0 14CP32W*81 14DP32W*81 14EP32W*81 14FP32W*81 14GP32W*81 14HP32W*81 14IP32W*81 14JG32W*81 — 612.00 664.00 793.00 1319.00 1680.00 2042.00 3782.00 4126.00 Use Size 0 14CP32F*81 14DP32F*81 14EP32F*81 14FP32F*81 14GP32F*81 14HP32F*81 14IP32F*81 14JG32F*81 — 673.00 729.00 873.00 1450.00 1847.00 2247.00 4160.00 4539.00 Use Size 0 14CP32H*81 14DP32H*81 14EP32H*81 14FP32H*81 14GP32H*81 14HP32H*81 14IP32H*81 14JG32H*81 — Use Size 0 1395.00 14CP320*81 1440.00 14DP320*81 1568.00 14EP320*81 1991.00 14FP320*81 2490.00 14GP320*81 3589.00 14HP320*81 4479.00 14IP320*81 4824.00 14JG320*81 — 414.00 457.00 586.00 888.00 1137.00 1387.00 3024.00 3368.00 Open Type & Standard Width Enclosure, Single Phase, 2-Pole Max Hp Enclosure Open Type NEMA 1 General Purpose NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight Watertight, Dust-tight NEMA 3 & 4 NEMA 12 NEMA 3/3R Corrosion Resistant 304 Stainless Steel Industrial Use Weatherproof Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Corrosion Resistant 115 Volts 208/230 Volts Contactor Amp NEMA Rating Size Half Size Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ 1 1 2 3 5 7 1⁄2 10 9 18 27 35 45 60 — — — — — 21⁄2 14BP12A*81 14CP12A*81 14DP12A*81 14EP12A*81 14FP12A*81 14GP12A*81 ⁄3 1 2 3 3 5 00 0 1 1P 2 — 203.00 262.00 306.00 400.00 555.00 754.00 14BP12B*81 14CP12B*81 14DP12B*81 14EP12B*81 14FP12B*81 14GP12B*81 219.00 279.00 323.00 418.00 418.00 875.00 Use Size 0 — Use Size 0 14CP12W*81 582.00 14CP12F*81 14DP12W*81 633.00 14DP12F*81 14EP12W*81 728.00 14EP12F*81 14FP12W*81 1262.00 14FP12F*81 14GP12W*81 1623.00 14GP12F*81 — 639.00 696.00 801.00 1389.00 1786.00 Use Size 0 14CP12H*81 14DP12H*81 14EP12H*81 14FP12H*81 14GP12H*81 — Use Size 0 — 1365.00 14CP120*81 383.00 1409.00 14DP120*81 426.00 1503.00 14EP120*81 521.00 1934.00 14FP120*81 831.00 2442.00 14GP120*81 1090.00 Extra Wide Enclosure, 3-Phase, 3-Pole Max Hp 200 Volts 1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 230 Volts 1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 Enclosure 460 Volts 2 5 10 15 25 30 50 75 100 575 Volts 2 5 10 15 25 30 50 75 100 NEMA 4/4X Stainless General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Contactor Amp NEMA Half Rating Size Size Catalog No 9 00 — 14BP82B*81 18 0 — 14CP82B*81 27 1 — 14DP82B*81 40 — 1 3⁄4 14EP82B*81 45 2 — 14FP82B*81 60 — 2 1⁄2 14GP82B*81 90 3 — 14HP82B*81 115 — 3 1⁄2 14IP82B*81 135 4 — 14JG82B*81 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All Starter Sizes carry one maximum Hp rating. For higher Hp single phase motors, use 3-phase starters, wire and set per diagram on page 16-130. 16-16 NEMA 1 List Price $ 467.00 528.00 570.00 700.00 846.00 1035.00 1352.00 2284.00 2628.00 Catalog No Use Size 0 14CP82W*81 14DP82W*81 14EP82W*81 14FP82W*81 14GP82W*81 14HP82W*81 14IP82W*81 14JG82W*81 List Price $ — 982.00 1025.00 1154.00 1912.00 2101.00 3782.00 4712.00 5057.00 To receive a single phase starter in an extra wide enclosure, order the enclosure kit from pg 16-90 and the open style starter from pg 16-14 or 16-16 as separate items. For conduit hubs and conversion instructions, see page 16-87. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3R Div 1 and Div 2 Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Industrial Use Weatherproof Catalog No Use Size 0 14CP82H*81 14DP82H*81 14EP82H*81 14FP82H*81 14GP82H*81 14HP82H*81 14IP82H*81 14JG82H*81 Catalog No Use Size 0 14CP820*81 14DP820*81 14EP820*81 14FP820*81 14GP820*81 14HP820*81 14IP820*81 14JG820*81 List Price $ — 2156.00 2224.00 2355.00 3440.00 4275.00 5443.00 8899.00 9244.00 List Price $ — 586.00 629.00 758.00 1215.00 1404.00 2317.00 3248.00 3592.00 Coils D, F, or G will be wired for incoming voltage. S coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. Standard Auxiliary Contacts, Same as Contactors, refer to page 16-44. For 316 Stainless Steel option see page 16-97. Discount Schedule NEMA Combination Heavy Duty Starters Features and Benefits General protect the control in varying degrees from physical damage and harmful atmospheres. All enclosures are supplied with corrosion resistant finishes. New Heavy Duty Disconnect Switches The disconnect switch that goes the distance in durability, performance and reliability has been made even better to give you greater advantages: Combination Starter Features Combination starters include the following features: A combination starter meets National Electrical Code requirements for: 1. A means of providing short circuit motor protection with fused or breaker disconnection of line voltage. ▪ Reduce Lead-time - What used to take days to get now takes minutes ▪ Reduced Inventory - Instead of stocking scores of various combination starters, simply stock a few enclosure kits, disconnect kits, circuit breaker kits and open starters. With these basic “building blocks” you virtually have hundreds of products on-hand ▪ Quality - The same high level of quality you have been accustomed to with our products will also be found in these new enclosure kits ▪ UL Listed - By correctly following the instructions included with the kits, the product you build is UL/CSA Listed Refer to page 16-90 for more details. Siemens Type ETI Circuit Breaker The ETI circuit breaker is a device designed specifically for application in motor circuits. The ETI is a magnetic only protective device designed to provide protection against short circuit current. The instantaneous-only type ETI circuit breaker employs adjustable magnetic trip settings to allow broader application ranges and a higher degree of motor short circuit protection. NEMA & General Purpose Control 2. A means of safeguarding personnel from contact with live parts and from accidental starting of machinery by disconnecting the motor and the controller. 3. A motor controller with overload protection. Prewired combination starters eliminate the cost of wiring between separate disconnect and starter. Factory testing assures field performance. Combination starters also provide a more compact and attractive installation than separate units. Enclosure Types Combination starters are available in NEMA 1, 12/3/3R/4 (painted), 4/4X (stainless), 4X fiberglass and 7 & 9 enclosures. Enclosures protect personnel from contact with live parts and depending upon the construction, CONTROL PRODUCTS Application What Is In It For You! 16 ▪ Manufactured with Cold Forming “TOX” Process ▪ Solid State Overloads Standard on Sizes 5–8 ▪ Easy to Install ▪ Wide Range of Enclosure Types Available ▪ Heavy Duty Quarter Turns ▪ 100kA Short Circuit Current Rating when Protected with Class R Fuses to 600V or MCP to 480V ▪ Visible Blade Disconnect ▪ Industrial Type Disconnect Handle ▪ Visible blades for the highest level of safety ▪ Double break switching action to reduce arcing, increase lifetime and eliminate the “electric hinge” ▪ More rugged positive action switch ▪ Oversized lugs are standard ▪ Line side shield to help guard personnel from contact with live parts ▪ Higher horsepower rating for design E high efficiency motors ▪ Now UL listed for IIsco, Burndy and T&B crimp type lugs ▪ The 200A switch now accepts up to 300 MCM versus 250 MCM wire size Its rugged construction - with a high fault withstand rating of 100kA at 600 VAC when fused with class R rated fuses - meets the most stringent industry standards set forth by the automotive, petro-chemical, and pulp and paper industries. UL recognized and CSA certified, our disconnect switches are available either non-fusible or fusible with class R and class J fuse clips. handle preinstalled. You install the required starter and fusible disconnect, connect the power wire and you are finished. Within minutes, you have the required combination starter in your hands. No more waiting on the factory. You need it, your got it! Enclosure Kits for NEMA Combination Starters Description Now you can assemble a non-stocked combination starter per your unanticipated needs in minutes. Say, for example, your customer needs a fusible combination starter that you don’t have in stock. You need in now, but don’t sweat it. Simply start with the newly offered enclosure kit which has the Heavy Duty Starters These combination starters use the same starters described in the heavy duty starter section of this catalog. ESP 100 solid state overload starters and ambient compensated bimetal overload starters are available. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-17 Combination Heavy Duty Starters Non-Fusible with Solid State Overload, Class 17 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. For Fusible Styles see page 16-21. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure, 3 Phase, 3-Pole Max Hp Enclosure NEMA 1 NEMA & General Purpose Control CONTROL PRODUCTS 16 General Purpose 200 Volts 1 ⁄6 1 ⁄2 2 3 1 ⁄6 1 ⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 20 30 40 75 150 — — 230 Volts 1 ⁄6 3 ⁄4 2 3 1 ⁄6 3 ⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 25 40 50 100 200 300 450 460 Volts 1 ⁄3 11⁄2 5 — 1 ⁄3 11⁄2 5 10 — 15 — 15 25 30 — 30 50 75 100 200 400 600 900 575 Volts 1 ⁄2 2 5 — 1 ⁄2 2 5 10 — 15 — 20 25 30 — 40 50 75 100 200 400 600 900 NEMA Size 0 0 0 0 1 1 1 1 1 — — 2 2 — — 3 3 — 4 5 6 7 8 Half Size — — — — — — — — — 1 3⁄4 1 3⁄4 — — 2 1⁄2 2 1⁄2 — — 3 1⁄2 — — — — — Overload Amp Range 0.25–1 0.75–3 2.5–10 9–18 0.25–1 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 55–250 160–540 420–820 420–1220 Disc Amp Rating 30 30 30 30 30 30 30 30 60 60 60 60 60 100 100 100 100 200 200 400 800 1200 1600 Catalog Number List Price $ 17CSA92B* 823.00 17CSB92B* 823.00 17CSD92B* 823.00 17CSE92B* 823.00 17DSA92B* 865.00 17DSB92B* 865.00 17DSD92B* 865.00 17DSE92B* 865.00 17DSF92B* 865.00 17ESF92B* 995.00 17ESG92B* 995.00 17FSF92B* 1348.00 17FSH92B* 1348.00 17GSH92B* 1822.00 17GSJ92B* 1822.00 17HSJ92B* 2219.00 17HSK92B* 2219.00 17ISL92B* 3899.00 17JTM92B* 4243.00 17LPU92B* 9476.00 17MPX92B* 24941.00 17NHY92B* 31118.00 17PHZ92B* 41812.00 NEMA 4/4X Stainless NEMA 4X Fiberglass Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Watertight, Dust-tight Corrosion Resistant Catalog Number 17CSA92W* 17CSB92W* 17CSD92W* 17CSE92W* 17DSA92W* 17DSB92W* 17DSD92W* 17DSE92W* 17DSF92W* 17ESF92W* 17ESG92W* 17FSF92W* 17FSH92W* 17GSH92W* 17GSJ92W* 17HSJ92W* 17HSK92W* 17ISL92W* 17JTM92W* 17LPU92E* 17MPX92E* — — NEMA 12, NEMA 3/3R, NEMA 4 Painted (thru Sz 4) Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 1650.00 17CSA92F* 1814.00 1650.00 17CSB92F* 1814.00 1650.00 17CSD92F* 1814.00 1650.00 17CSE92F* 1814.00 1693.00 17DSA92F* 1863.00 1693.00 17DSB92F* 1863.00 1693.00 17DSD92F* 1863.00 1693.00 17DSE92F* 1863.00 1693.00 17DSF92F* 1863.00 1822.00 17ESF92F* 2003.00 1822.00 17ESG92F* 2003.00 2623.00 17FSF92F* 2886.00 2623.00 17FSH92F* 2886.00 4045.00 17GSH92F* 4450.00 4045.00 17GSJ92F* 4450.00 4440.00 17HSJ92F* 4886.00 4440.00 17HSK92F* 4886.00 6741.00 17ISL92F* 7415.00 7086.00 17JTM92F* 7795.00 16730.00 — — 32694.00 — — — — — — — — Catalog Number 17CSA92N* 17CSB92N* 17CSD92N* 17CSE92N* 17DSA92N* 17DSB92N* 17DSD92N* 17DSE92N* 17DSF92N* 17ESF92N* 17ESG92N* 17FSF92N* 17FSH92N* 17GSH92N* 17GSJ92N* 17HSJ92N* 17HSK92N* 17ISL92N* 17JTM92N* 17LPU92N* 17MPX92N* 17NHY92N* 17PHZ92N* List Price $ 1030.00 1030.00 1030.00 1030.00 1072.00 1072.00 1072.00 1072.00 1072.00 1202.00 1202.00 1641.00 1641.00 2201.00 2201.00 2598.00 2598.00 4950.00 5294.00 11949.00 27912.00 33444.00 44139.00 Standard Width Enclosure, Single Phase, (Catalog Numbers are three phase, wire for single phase in the field) Max Hp Enclosure NEMA 1 General Purpose 115 Volts 1 ⁄8 1 ⁄4 1 1 ⁄8 1 ⁄4 1 208/ 230 Volts 1 ⁄4 1 ⁄2 2 1 ⁄4 1 ⁄2 2 NEMA Size 0 0 0 1 1 1 Overload Amp Range 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 Disc Amp Rating 30 30 30 30 30 30 Catalog Number 17CSB92B* 17CSD92B* 17CSE92B* 17DSB92B* 17DSD92B* 17DSE92B* Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Dual voltage coils not available in modified starters or in starter sizes 5–8. For conduit hubs and conversion instructions, see page 16-87. 16-18 List Price $ 823.00 823.00 823.00 865.00 865.00 865.00 NEMA 4/4X Stainless NEMA 4X Fiberglass Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Watertight, Dust-tight Corrosion Resistant Catalog Number 17CSB92W* 17CSD92W* 17CSE92W* 17DSB92W* 17DSD92W* 17DSE92W* List Price $ 1650.00 1650.00 1650.00 1693.00 1693.00 1693.00 Catalog Number 17CSB92F* 17CSD92F* 17CSE92F* 17DSB92F* 17DSD92F* 17DSE92F* For For 60A disconnect, order fusible cat. no. page 16-21. 25 HP and 200A disconnect, order fusible cat. no. page 16-21. For 30HP and 200A disconnect, order fusible cat. no. page 16-21. For 600A disconnect, order fusible cat. no. page 16-21. Enclosure is NEMA Type 4 (painted steel). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEMA 12, NEMA 3/3R, NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ 1814.00 1814.00 1814.00 1863.00 1863.00 1863.00 Catalog Number 17CSB92N* 17CSD92N* 17CSE92N* 17DSB92N* 17DSD92N* 17DSE92N* List Price $ 1030.00 1030.00 1030.00 1072.00 1072.00 1072.00 For a single phase motor, multiply the motor nameplate by 0.75 and set the OL dial to the resulting value. F coil 100-250V AC 50/60Hz, or DC, H coil 150-500V AC 50/60Hz, or DC Only available F coil 100-250V AC 50/60Hz, or DC For 316 Stainless Steel option see page 16-97. Discount Schedule NEMA Combination Heavy Duty Starters Non-Fusible with Solid State Overload, Class 17 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. For Fusible Styles see page 16-21. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Extra Wide Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 1 NEMA 4/4X Stainless General Purpose 460 Volts 1 ⁄3 11⁄2 5 — 1 ⁄3 11⁄2 5 10 — 15 — 15 25 30 — 30 50 575 Volts 1 ⁄2 2 5 — 1 ⁄2 2 5 10 — 15 — 20 25 30 — 40 50 NEMA Size 0 0 0 0 1 1 1 1 1 — — 2 2 — — 3 3 Half Size — — — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — Catalog Number 17CSA82B* 17CSB82B* 17CSD82B* 17CSE82B* 17DSA82B* 17DSB82B* 17DSD82B* 17DSE82B* 17DSF82B* 17ESF82B* 17ESG82B* 17FSF82B* 17FSH82B* 17GSH82B* 17GSJ82B* 17HSJ82B* 17HSK82B* List Price $ 1037.00 1037.00 1037.00 1037.00 1082.00 1082.00 1082.00 1082.00 1082.00 1210.00 1210.00 1563.00 1563.00 2253.00 2253.00 2649.00 2649.00 Catalog Number 17CSA82W* 17CSB82W* 17CSD82W* 17CSE82W* 17DSA82W* 17DSB82W* 17DSD82W* 17DSE82W* 17DSF82W* 17ESF82W* 17ESG82W* 17FSF82W* 17FSH82W* 17GSH82W* 17GSJ82W* 17HSJ82W* 17HSK82W* List Price $ 2295.00 2295.00 2295.00 2295.00 2339.00 2339.00 2339.00 2339.00 2339.00 2468.00 2468.00 3270.00 3270.00 5337.00 5337.00 5733.00 5733.00 Industrial Use Weatherproof Watertight, Dust-tight Catalog Number 17CSA82N* 17CSB82N* 17CSD82N* 17CSE82N* 17DSA82N* 17DSB82N* 17DSD82N* 17DSE82N* 17DSF82N* 17ESF82N* 17ESG82N* 17FSF82N* 17FSH82N* 17GSH82N* 17GSJ82N* 17HSJ82N* 17HSK82N* List Price $ 1416.00 1416.00 1416.00 1416.00 1461.00 1461.00 1461.00 1461.00 1461.00 1589.00 1589.00 2029.00 2029.00 2977.00 2977.00 3373.00 3373.00 CONTROL PRODUCTS 230 Volts 1 ⁄6 3 ⁄4 2 3 1 ⁄6 3 ⁄4 2 3 71⁄2 — 10 — 15 — 20 — 20 Disc Amp Rating 30 30 30 30 30 30 30 30 60 60 60 60 60 100 100 100 100 NEMA 12, NEMA 3/3R, NEMA 4 Painted 16 200 Volts 1 ⁄6 1 ⁄2 2 3 1 ⁄6 1 ⁄2 2 3 71⁄2 — 10 — 10 — 15 — 20 Overload Amp Range 0.25–1 0.75–3 2.5–10 9–18 0.25–1 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) NEMA & General Purpose Control Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one Hp rating. Discount Schedule NEMA Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see page For 16-87. For 60A disconnect, order fusible cat. no. page 16-22. For 25 HP and 200A disconnect, order fusible cat. no. page 16-22. 30HP and 200A disconnect, order fusible cat. no. page 16-22. For 316 Stainless Steel option see page 16-97. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-19 Combination Heavy Duty Starters Non-Fusible with Ambient Compensated Bimetal Overload, Class 17 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (3 required) Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 1 General Purpose NEMA & General Purpose Control CONTROL PRODUCTS 16 200 Volts 3 71⁄2 10 10 15 25 30 40 230 Volts 3 71⁄2 10 15 20 30 40 50 460 Volts 5 10 15 25 30 50 75 100 575 Volts 5 10 15 25 30 50 75 100 Contactor Amp Rating 18 27 40 45 60 90 115 135 Disc NEMA Half Amp Size Size Rating 0 — 30 1 — 30 3 — 1 ⁄4 60 2 — 60 1 — 2 ⁄2 100 3 — 100 1 — 3 ⁄2 200 4 — 200 Catalog Number 17CP92B*81 17DP92B*81 17EP92B*81 17FP92B*81 17GP92B*81 17HP92B*81 17IP92B*81 17JP92B*81 List Price $ 784.00 827.00 957.00 1309.00 1784.00 2180.00 3859.00 4204.00 NEMA 4/4X Stainless NEMA 4X Fiberglass Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Watertight, Dust-tight Corrosion Resistant Catalog Number 17CP92W*81 17DP92W*81 17EP92W*81 17FP92W*81 17GP92W*81 17HP92W*81 17IP92W*81 17JP92W*81 Catalog Number 17CP92F*81 17DP92F*81 17EP92F*81 17FP92F*81 17GP92F*81 17HP92F*81 17IP92F*81 17JP92F*81 List Price $ 1612.00 1654.00 1784.00 2584.00 4006.00 4403.00 6703.00 7048.00 NEMA 12, NEMA 3/3R, NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 1773.00 17CP92N*81 991.00 1820.00 17DP92N*81 1033.00 1962.00 17EP92N*81 1163.00 2743.00 17FP92N*81 1602.00 4407.00 17GP92N*81 2163.00 4844.00 17HP92N*81 2559.00 7374.00 17IP92N*81 4910.00 7753.00 17JP92N*81 5254.00 Extra Wide Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 1 NEMA 4/4X Stainless General Purpose 200 Volts 3 71⁄2 10 10 15 25 230 Volts 3 71⁄2 10 15 20 30 460 Volts 5 10 15 25 30 50 Contactor 575 Amp Volts Rating 5 18 10 27 15 40 25 45 30 60 50 90 Disc NEMA Half Amp Size Size Rating 0 — 30 1 — 30 3 — 1 ⁄4 60 2 — 60 1 — 2 ⁄2 100 3 — 100 NEMA 12, NEMA 3/3R, NEMA 4 Painted Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Catalog Number 17CP82B*81 17DP82B*81 17EP82B*81 17FP82B*81 17GP82B*81 17HP82B*81 List Price $ 1000.00 1043.00 1172.00 1526.00 2214.00 2610.00 Catalog Number 17CP82W*81 17DP82W*81 17EP82W*81 17FP82W*81 17GP82W*81 17HP82W*81 Industrial Use Weatherproof Watertight, Dust-tight List Price $ 2256.00 2301.00 2430.00 3231.00 5298.00 5694.00 Catalog Number 17CP82N*81 17DP82N*81 17EP82N*81 17FP82N*81 17GP82N*81 17HP82N*81 List Price $ 1379.00 1422.00 1551.00 1991.00 2938.00 3334.00 Standard Width Enclosure, Single Phase, (Catalog Numbers are three phase, wire for single phase in the field) Max Hp Enclosure NEMA 1 General Purpose 115 Volts 1 2 3 3 5 208/ Contactor Disc 230 Amp NEMA Half Amp Volts Rating Size Size Rating 2 18 0 — 30 3 27 1 — 30 5 35 1P — 60 45 2 — 60 71⁄2 10 60 — 21⁄2 100 Catalog Number List Price $ 17CP92B*81 784.00 17DP92B*81 827.00 17EP92B*81 957.00 17FP92B*81 1309.00 17GP92B*81 1784.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-20 NEMA 4/4X Stainless NEMA 4X Fiberglass Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Watertight, Dust-tight Corrosion Resistant Catalog Number 17CP92W*81 17DP92W*81 17EP92W*81 17FP92W*81 17GP92W*81 List Price $ 1612.00 1654.00 1784.00 2584.00 4006.00 Catalog Number 17CP92F*81 17DP92F*81 17EP92F*81 17FP92F*81 17GP92F*81 Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see page 16-87. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog For For For NEMA 12, NEMA 3/3R, NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ 1773.00 1820.00 1962.00 2743.00 4407.00 Catalog Number 17CP92N*81 17DP92N*81 17EP92N*81 17FP92N*81 17GP92N*81 List Price $ 991.00 1033.00 1163.00 1602.00 2163.00 60A disc, order fusible cat. no. page 16-23. 200A disc, order fusible cat. no. page 16-23. 316 Stainless Steel option see page 16-97. Discount Schedule NEMA Combination Heavy Duty Starters Fusible with Solid State Overload, Class 17 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 1 General Purpose 575 Volts — 1 ⁄2 — 2 — 5 — — 1 ⁄2 — 2 — 5 — 10 — — 15 — 20 — 25 30 — — 40 — 50 — — 75 — 100 — — 125 200 — — 400 400 600 900 NEMA Size 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 — — 2 2 2 — — — 3 3 3 — — — 4 4 5 5 5 5 5 6 6 6 7��� 8��� Half Size — — — — — — — — — — — — — — — — — 13⁄4 13⁄4 — — — 21⁄2 21⁄2 21⁄2 — — — — 31⁄2 31⁄2 — — — — — — — — — — — — Overload Amp Range 0.25–1 0.25–1 0.75–3 0.75–3 2.5–10 2.5–10 9–18 0.25–1 0.25–1 0.75–3 0.75–3 2.5–10 2.5–10 9–18 9–18 13–27 13–27 13–27 20–40 13–27 22–45 22–45 22–45 22–45 30–60 30–60 45–90 45–90 45–90 57–115 57–115 67–135 67–135 55–250 55–250 55–250 55–250 55–250 160–540 160–540 160–540 420–820 420–1220 Disc Amp Rating 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 60 60 60 60 60 60 60 100 100 100 100 100 200 200 200 200 200 400 600 400 400 600 600 600 800 1200 1600 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA Fuse Clip Size Amps/Volts 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 60A/250V 60A/600V 60A/250V 60A/600V 60A/250V 60A/600V 60A/600V 100A/600V 100A/250V 100A/600V 100A/250V 100A/600V 200A/250V 200A/250V 200A/600V 200A/250V 200A/600V 400A/250V 600A/250V��� 200A/600V 400A/600V 600A/600V��� 600A/250V 600A/600V 800A/600V 1200A/600V 1600A/600V Dual Catalog Number 17CSA92B*10 17CSA92B*11 17CSB92B*10 17CSB92B*11 17CSD92B*10 17CSD92B*11 17CSE92B*10 17DSA92B*10 17DSA92B*11 17DSB92B*10 17DSB92B*11 17DSD92B*10 17DSD92B*11 17DSE92B*10 17DSE92B*11 17DSF92B*10 17DSF92B*12 17ESF92B*13 17ESG92B*12 17FSF92B*13 17FSH92B*12 17FSH92B*13 17GSH92B*13 17GSH92B*15 17GSJ92B*14 17HSJ92B*15 17HSK92B*14 17HSK92B*15 17HSK92B*16 17ISL92B*16 17ISL92B*17 17JTM92B*16 17JTM92B*17 17LPU92B*18 17LPU92B*20 17LPU92B*17 17LPU92B*19 17LPU92B*21 17MPX92B*20 17MPX92B*21 17MPX92B*23 17NHY92B*23 17PHZ92B*25 List Price $ 848.00 866.00 848.00 866.00 848.00 866.00 848.00 891.00 909.00 891.00 909.00 891.00 909.00 891.00 909.00 891.00 909.00 1055.00 1038.00 1409.00 1390.00 1409.00 1882.00 1959.00 1959.00 2356.00 2356.00 2356.00 2528.00 4208.00 4208.00 4553.00 4553.00 10114.00 10390.00 9786.00 10114.00 10390.00 25854.00 25854.00 26997.00 33174.00 46953.00 Catalog Number 17CSA92W*10 17CSA92W*11 17CSB92W*10 17CSB92W*11 17CSD92W*10 17CSD92W*11 17CSE92W*10 17DSA92W*10 17DSA92W*11 17DSB92W*10 17DSB92W*11 17DSD92W*10 17DSD92W*11 17DSE92W*10 17DSE92W*11 17DSF92W*10 17DSF92W*12 17ESF92W*13 17ESG92W*12 17FSF92W*13 17FSH92W*12 17FSH92W*13 17GSH92W*13 17GSH92W*15 17GSJ92W*14 17HSJ92W*15 17HSK92W*14 17HSK92W*15 17HSK92W*16 17ISL92W*16 17ISL92W*17 17JTM92W*16 17JTM92W*17 17LPU92E*18 17LPU92E*20 17LPU92E*17 17LPU92E*19 17LPU92E*21 17MPX92E*20 17MPX92E*21 17MPX92E*23 — — Catalog Number 17CSA92F*10 17CSA92F*11 17CSB92F*10 17CSB92F*11 17CSD92F*10 17CSD92F*11 17CSE92F*10 17DSA92F*10 17DSA92F*11 17DSB92F*10 17DSB92F*11 17DSD92F*10 17DSD92F*11 17DSE92F*10 17DSE92F*11 17DSF92F*10 17DSF92F*12 17ESF92F*13 17ESG92F*12 17FSF92F*13 17FSH92F*12 17FSH92F*13 17GSH92F*13 17GSH92F*15 17GSJ92F*14 17HSJ92F*15 17HSK92F*14 17HSK92F*15 17HSK92F*16 17ISL92F*16 17ISL92F*17 17JTM92F*16 17JTM92F*17 — — — — — — — — — — voltage coils not available in modified starters or in starter sizes 5–8. conduit hubs and conversion instructions, see page 16-87. Use Class J fuses only. Enclosure is NEMA Type 4 (painted steel). For List Price $ 1675.00 1693.00 1675.00 1693.00 1675.00 1693.00 1675.00 1719.00 1737.00 1719.00 1737.00 1719.00 1737.00 1719.00 1737.00 1719.00 1737.00 1882.00 1865.00 2684.00 2667.00 2684.00 4106.00 4182.00 4182.00 4578.00 4578.00 4578.00 4750.00 7051.00 7051.00 7396.00 7396.00 17368.00 17644.00 17039.00 17368.00 17644.00 33108.00 33108.00 34251.00 — — List Price $ 1843.00 1863.00 1843.00 1863.00 1843.00 1863.00 1843.00 1891.00 1911.00 1891.00 1911.00 1891.00 1911.00 1891.00 1911.00 1891.00 1911.00 2052.00 2071.00 2953.00 2935.00 2953.00 4517.00 4600.00 4600.00 5037.00 5037.00 5037.00 5226.00 7756.00 7756.00 8136.00 8136.00 — — — — — — — — — — NEMA 12, NEMA 3/3R, NEMA 4 Painted (thru Sz 4) Industrial Use Weatherproof Watertight, Dust-tight Catalog Number 17CSA92N*10 17CSA92N*11 17CSB92N*10 17CSB92N*11 17CSD92N*10 17CSD92N*11 17CSE92N*10 17DSA92N*10 17DSA92N*11 17DSB92N*10 17DSB92N*11 17DSD92N*10 17DSD92N*11 17DSE92N*10 17DSE92N*11 17DSF92N*10 17DSF92N*12 17ESF92N*13 17ESG92N*12 17FSF92N*13 17FSH92N*12 17FSH92N*13 17GSH92N*13 17GSH92N*15 17GSJ92N*14 17HSJ92N*15 17HSK92N*14 17HSK92N*15 17HSK92N*16 17ISL92N*16 17ISL92N*17 17JTM92N*16 17JTM92N*17 17LPU92N*18 17LPU92N*20 17LPU92N*17 17LPU92N*19 17LPU92N*21 17MPX92N*20 17MPX92N*21 17MPX92N*23 17NHY92N*23 17PHZ92N*25 List Price $ 1055.00 1073.00 1055.00 1073.00 1055.00 1073.00 1055.00 1098.00 1116.00 1098.00 1116.00 1098.00 1116.00 1098.00 1116.00 1098.00 1116.00 1262.00 1245.00 1702.00 1685.00 1702.00 2261.00 2338.00 2338.00 2735.00 2735.00 2735.00 2907.00 5259.00 5259.00 5604.00 5604.00 12664.00 12940.00 12336.00 12664.00 12940.00 28827.00 28827.00 29969.00 35499.00 49279.00 Single phase wiring page 16-130. F coil 100-250V AC 50/60Hz, or DC, H coil 150-500V AC 50/60Hz, or DC available F coil 100-250V AC 50/60Hz, or DC For 316 Stainless Steel option see page 16-97. Only Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-21 NEMA & General Purpose Control 460 Volts — 1 ⁄3 — 11⁄2 — 5 — — 1 ⁄3 — 11⁄2 — 5 — 10 — — 15 — 15 — 25 — 30 — 30 — 50 — — 75 — 100 — — — 200 200 — 400 400 600 900 Watertight, Dust-tight Corrosion Resistant CONTROL PRODUCTS 230 Volts 1 ⁄6 — 3 ⁄4 — 2 — 3 1 ⁄6 — 3 ⁄4 — 2 — 3 — 5 71⁄2 — 10 — 15 — — — 20 — 25 — 30 40 — 50 — 100 100 — — — 200 — — — — NEMA 4X Fiberglass Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) 16 200 Volts 1 ⁄6 — 1 ⁄2 — 2 — 3 1 ⁄6 — 1 ⁄2 — 2 — 3 — 5 71⁄2 — 10 — 10 — — — 15 — 20 — 25 30 — 40 — 75 — — — — 150 — — — — NEMA 4/4X Stainless Combination Heavy Duty Starters Fusible with Solid State Overload, Class 17 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Extra Wide Enclosure, 3-Phase, 3-Pole NEMA & General Purpose Control CONTROL PRODUCTS 16 Max Hp Enclosure NEMA 4/4X St-less General Purpose Watertight, Dust-tight, Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Fuse Clip Size Amps/ 200 230 460 575 NEMA Half Overload Amp Volts Volts Volts Volts Size Size Range Rating Volts Catalog Number List Price $ Catalog Number 1 1 — 1 ⁄3 — 11⁄2 — 5 — — 1 ⁄3 — 11⁄2 — 5 — 10 — — 15 — 15 — 25 — 30 — 30 — 50 — — 1 ⁄2 — 2 — 5 — — 1 ⁄2 — 2 — 5 — 10 — — 15 — 20 — 25 30 — — 40 — 50 — 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 — — 2 2 2 — — — 3 3 3 3 — — — — — — — — — — — — — — — — — 13⁄4 13⁄4 — — — 21⁄2 21⁄2 21⁄2 — — — — 0.25–1 0.25–1 0.75–3 0.75–3 2.5–10 2.5–10 9–18 0.25–1 0.25–1 0.75–3 0.75–3 2.5–10 2.5–10 9–18 9–18 13–27 13–27 13–27 20–40 13–27 22–45 22–45 22–45 22–45 30–60 30–60 45–90 45–90 45–90 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 60 60 60 60 60 60 60 100 100 100 100 100 200 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 30A/600V 30A/250V 60A/250V 60A/600V 60A/250V 60A/600V 60A/250V 60A/600V 60A/600V 100A/600V 100A/250V 100A/600V 100A/250V 100A/600V 200A/250V 17CSA82B*10 17CSA82B*11 17CSB82B*10 17CSB82B*11 17CSD82B*10 17CSD82B*11 17CSE82B*10 17DSA82B*10 17DSA82B*11 17DSB82B*10 17DSB82B*11 17DSD82B*10 17DSD82B*11 17DSE82B*10 17DSE82B*11 17DSF82B*10 17DSF82B*12 17ESF82B*13 17ESG82B*12 17FSF82B*13 17FSH82B*12 17FSH82B*13 17GSH82B*13 17GSH82B*15 17GSJ82B*14 17HSJ82B*15 17HSK82B*14 17HSK82B*15 17HSK82B*16 ⁄6 — 1 ⁄2 — 2 — 3 1 ⁄6 — 1 ⁄2 — 2 — 3 — 5 71⁄2 — 10 — 10 — — — 15 — 20 — 25 ⁄6 — 3 ⁄4 — 2 — 3 1 ⁄6 — 3 ⁄4 — 2 — 3 — 5 71⁄2 — 10 — 15 — — — 20 — 25 — 30 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-22 Disc Amp NEMA 1 1064.00 1082.00 1064.00 1082.00 1064.00 1082.00 1064.00 1107.00 1125.00 1107.00 1125.00 1107.00 1125.00 1107.00 1125.00 1107.00 1125.00 1270.00 1254.00 1623.00 1606.00 1623.00 2313.00 2391.00 2391.00 2787.00 2787.00 2787.00 2955.00 17CSA82W*10 17CSA82W*11 17CSB82W*10 17CSB82W*11 17CSD82W*10 17CSD82W*11 17CSE82W*10 17DSA82W*10 17DSA82W*11 17DSB82W*10 17DSB82W*11 17DSD82W*10 17DSD82W*11 17DSE82W*10 17DSE82W*11 17DSF82W*10 17DSF82W*12 17ESF82W*13 17ESG82W*12 17FSF82W*13 17FSH82W*12 17FSH82W*13 17GSH82W*13 17GSH82W*15 17GSJ82W*14 17HSJ82W*15 17HSK82W*14 17HSK82W*15 17HSK82W*16 NEMA 12, NEMA 3/3R, NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 2322.00 2339.00 2322.00 2339.00 2322.00 2339.00 2322.00 2365.00 2384.00 2365.00 2384.00 2365.00 2384.00 2365.00 2384.00 2365.00 2384.00 2512.00 2512.00 3331.00 3314.00 3331.00 5398.00 5475.00 5475.00 5871.00 5871.00 5871.00 6044.00 17CSA82N*10 17CSA82N*11 17CSB82N*10 17CSB82N*11 17CSD82N*10 17CSD82N*11 17CSE82N*10 17DSA82N*10 17DSA82N*11 17DSB82N*10 17DSB82N*11 17DSD82N*10 17DSD82N*11 17DSE82N*10 17DSE82N*11 17DSF82N*10 17DSF82N*12 17ESF82N*13 17ESG82N*12 17FSF82N*13 17FSH82N*12 17FSH82N*13 17GSH82N*13 17GSH82N*15 17GSJ82N*14 17HSJ82N*15 17HSK82N*14 17HSK82N*15 17HSK82N*16 1443.00 1461.00 1443.00 1461.00 1443.00 1461.00 1443.00 1486.00 1504.00 1486.00 1504.00 1486.00 1504.00 1486.00 1504.00 1486.00 1504.00 1650.00 1633.00 2088.00 2072.00 2088.00 3038.00 3114.00 3114.00 3510.00 3510.00 3510.00 3682.00 Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see page 16-87. 316 Stainless Steel option see page 16-97. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Combination Heavy Duty Starters Fusible with Ambient Compensated Bimetal Overload, Class 17 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (3 required) Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure, 3-Phase, 3-Pole Max Hp NEMA Size 0 0 1 1 1 — — 2 2 — — — 3 3 3 — — 4 4 Half Size — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 21⁄2 — — — 31⁄2 31⁄2 — — Disc Amp Rating 30 30 30 30 60 60 60 60 60 60 100 100 100 100 200 200 200 200 200 Fuse Clip Size Amps/Volts 30A/250V 30A/600V 30A/250V 30A/600V 60A/250V 60A/250V 60A/600V 60A/250V 60A/600V 60A/600V 100A/600V 100A/250V 100A/250V 100A/600V 200A/250V 200A/250V 200A/600V 200A/250V 200A/600V NEMA 4/4X Stainless NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) Watertight, Dust-tight Corrosion Resistant Catalog List Number Price $ 17CP92W*1081 1637.00 17CP92W*1181 1655.00 17DP92W*1081 1680.00 17DP92W*1181 1698.00 17DP92W*1281 1698.00 17EP92W*1281 1827.00 17EP92W*1381 1844.00 17FP92W*1281 2628.00 17FP92W*1381 2645.00 17GP92W*1381 4066.00 17GP92W*1581 4143.00 17GP92W*1481 4143.00 17HP92W*1481 4540.00 17HP92W*1581 4540.00 17HP92W*1681 4712.00 17IP92W*1681 7013.00 17IP92W*1781 7013.00 17JP92W*1681 7357.00 17JP92W*1781 7357.00 Catalog List Number Price $ 17CP92F*1081 1802.00 17CP92F*1181 1821.00 17DP92F*1081 1848.00 17DP92F*1181 1868.00 17DP92F*1281 1868.00 17EP92F*1281 2011.00 17EP92F*1381 2029.00 17FP92F*1281 2891.00 17FP92F*1381 2910.00 17GP92F*1381 4473.00 17GP92F*1581 4580.00 17GP92F*1481 4580.00 17HP92F*1481 4994.00 17HP92F*1581 4994.00 17HP92F*1681 5184.00 17IP92F*1681 7714.00 17IP92F*1781 7714.00 17JP92F*1681 8092.00 17JP92F*1781 8092.00 Catalog Number 17CP92B*1081 17CP92B*1181 17DP92B*1081 17DP92B*1181 17DP92B*1281 17EP92B*1281 17EP92B*1381 17FP92B*1281 17FP92B*1381 17GP92B*1381 17GP92B*1581 17GP92B*1481 17HP92B*1481 17HP92B*1581 17HP92B*1681 17IP92B*1681 17IP92B*1781 17JP92B*1681 17JP92B*1781 List Price $ 810.00 827.00 854.00 872.00 872.00 1000.00 1016.00 1353.00 1370.00 1844.00 1922.00 1922.00 2317.00 2317.00 2490.00 4168.00 4168.00 4514.00 4514.00 NEMA 12, NEMA 3/3R, NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight Catalog Number 17CP92N*1081 17CP92N*1181 17DP92N*1081 17DP92N*1181 17DP92N*1281 17EP92N*1281 17EP92N*1381 17FP92N*1281 17FP92N*1381 17GP92N*1381 17GP92N*1581 17GP92N*1481 17HP92N*1481 17HP92N*1581 17HP92N*1681 17IP92N*1681 17IP92N*1781 17JP92N*1681 17JP92N*1781 List Price $ 1016.00 1034.00 1059.00 1077.00 1077.00 1206.00 1223.00 1646.00 1663.00 2223.00 2301.00 2301.00 2696.00 2696.00 3987.00 5220.00 5220.00 5564.00 5564.00 CONTROL PRODUCTS 230 Volts 3 — 5 — 7 1⁄2 10 — 15 — — — 20 25 — 30 40 — 50 — Contactor 460 575 Amp Volts Volts Rating — — 18 5 5 18 — — 27 10 10 27 — — 27 — — 40 15 15 40 — — 45 25 25 45 — 30 60 30 — 60 — — 60 — — 90 50 50 90 — — 90 — — 115 75 75 115 — — 135 100 100 135 NEMA 1 16 200 Volts 3 — 5 — 7 1⁄2 10 — 10 — — — 15 20 — 25 30 — 40 — Enclosure Extra Wide Enclosure, 3-Phase, 3-Pole 200 Volts 3 — 5 — 7 1⁄2 10 — 10 — — — 15 20 — 25 Enclosure 230 Volts 3 — 5 — 7 1⁄2 10 — 15 — — — 20 25 — 30 460 Volts — 5 — 10 — — 15 — 25 — 30 — — 50 — 575 Volts — 5 — 10 — — 15 — 25 30 — — — 50 — Contactor Amp Rating 18 18 27 27 27 40 40 45 45 60 60 60 90 90 90 NEMA Size 0 0 1 1 1 — — 2 2 — — — 3 3 3 Half Size — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 21⁄2 — — — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA Disc Amp Rating 30 30 30 30 60 60 60 60 60 60 100 100 100 100 200 Fuse Clip Size Amps/Volts 30A/250V 30A/600V 30A/250V 30A/600V 60A/250V 60A/250V 60A/600V 60A/250V 60A/600V 60A/600V 100A/600V 100A/250V 100A/250V 100A/600V 200A/250V NEMA 1 NEMA 4/4X Stainless General Purpose Watertight, Dust-tight Industrial Use Weatherproof 304 Stainless Steel 316 Stainless Steel (optional) Industrial Use Weatherproof Watertight, Dust-tight Catalog Number 17CP82W*1081 17CP82W*1181 17DP82W*1081 17DP82W*1181 17DP82W*1281 17EP82W*1281 17EP82W*1381 17FP82W*1281 17FP82W*1381 17GP82W*1381 17GP82W*1581 17GP82W*1481 17HP82W*1481 17HP82W*1581 17HP92W*1681 Catalog Number 17CP82N*1081 17CP82N*1181 17DP82N*1081 17DP82N*1181 17DP82N*1281 17EP82N*1281 17EP82N*1381 17FP82N*1281 17FP82N*1381 17GP82N*1381 17GP82N*1581 17GP82N*1481 17HP82N*1481 17HP82N*1581 17HP92N*1681 Catalog Number 17CP82B*1081 17CP82B*1181 17DP82B*1081 17DP82B*1181 17DP82B*1281 17EP82B*1281 17EP82B*1381 17FP82B*1281 17FP82B*1381 17GP82B*1381 17GP82B*1581 17GP82B*1481 17HP82B*1481 17HP82B*1581 17HP92B*1681 List Price $ 1026.00 1044.00 1068.00 1086.00 1086.00 1216.00 1233.00 1569.00 1586.00 2274.00 2352.00 2352.00 2748.00 2748.00 2490.00 Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see page For List Price $ 2283.00 2301.00 2326.00 2344.00 2344.00 2474.00 2491.00 3274.00 3291.00 5358.00 5436.00 5436.00 5832.00 5832.00 4712.00 NEMA 12, NEMA 3/3R, NEMA 4 Painted List Price $ 1405.00 1423.00 1447.00 1465.00 1465.00 1595.00 1612.00 2034.00 2051.00 2998.00 3075.00 3075.00 3471.00 3471.00 3987.00 316 Stainless Steel option see page 16-97. 16-87. Single phase wiring page 16-130. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-23 NEMA & General Purpose Control Max Hp Combination Heavy Duty Starters MCP Type with Solid State Overload, Class 18 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 1 General Purpose NEMA & General Purpose Control CONTROL PRODUCTS 16 200 230 460 575 NEMA Half Volts Volts Volts Volts Size Size 1 ⁄2 2 3 1 ⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 50 75 100 150 — — — — 1 ⁄2 2 3 1 ⁄2 2 3 7 1⁄2 — 10 — 15 — 20 — 30 40 50 75 100 125 200 250 300 400 450 1 5 — 1 5 7 1⁄2 10 15 — 15 25 30 — 30 50 75 100 150 200 250 400 500 600 800 900 1 5 — 1 5 10 — 15 — 20 25 30 — 30 50 75 100 200 — 300 400 500 600 800 900 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 5 5 6 6 7 7 8 8 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — — — — — — — — — Overload Amp Range Motor Circuit Interrupter ETI Amps 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 55–250 55–250 160–540 160–540 420–820 420–820 420–1220 420–1220 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-24 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 125 150 250 400 400 600 800 1000 1200 1600 NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight Watertight, Dust-tight NEMA 3, 4 Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (optional) NEMA 12, NEMA 3/3R NEMA 4 Painted (thru Sz 4) Corrosion Resistant Div 1 and Div 2 Industrial Use Class I Groups C&D Weatherproof Class II Groups E, F&G Watertight, Dust-tight Class III Bolted Enclosures Indoor/Outdoor Use Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Catalog Price $ Number 18CSB92B* 18CSD92B* 18CSE92B* 18DSB92B* 18DSD92B* 18DSE92B* 18DSF92B* 18ESF92B* 18ESG92B* 18FSF92B* 18FSH92B* 18GSH92B* 18GSJ92B* 18HSJ92B* 18HSK92B* 18ISL92B* 18JTM92B* 18LPT92B* 18LPU92B* 18MPW92B* 18MPX92B* 18NHV92B* 18NHY92B* 18PHZ92B* 18PH192B* 1133.00 1133.00 1133.00 1176.00 1176.00 1176.00 1176.00 1305.00 1305.00 1305.00 1650.00 2192.00 2192.00 2381.00 2381.00 4837.00 5182.00 11967.00 11967.00 25349.00 25940.00 35021.00 35021.00 52095.00 52095.00 18CSB92W* 18CSD92W* 18CSE92W* 18DSB92W* 18DSD92W* 18DSE92W* 18DSF92W* 18ESF92W* 18ESG92W* 18FSF92W* 18FSH92W* 18GSH92W* 18GSJ92W* 18HSJ92W* 18HSK92W* 18ISL92W* 18JTM92W* 18LPT92E* 18LPU92E* 18MPW92E* 18MPX92E* — — — — 1960.00 1960.00 1960.00 2002.00 2002.00 2002.00 2002.00 2133.00 2133.00 2925.00 2925.00 4415.00 4415.00 4605.00 4605.00 7680.00 8024.00 19220.00 19811.00 29657.00 30247.00 — — — — 18CSB92F* 18CSD92F* 18CSE92F* 18DSB92F* 18DSD92F* 18DSE92F* 18DSF92F* 18ESF92F* 18ESG92F* 18FSF92F* 18FSH92F* 18GSH92F* 18GSJ92F* 18HSJ92F* 18HSK92F* 18ISL92F* 18JTM92F* — — — — — — — — 2157.00 2157.00 2157.00 2204.00 2204.00 2204.00 2204.00 2346.00 2346.00 3218.00 3218.00 4856.00 4856.00 5065.00 5065.00 8448.00 8827.00 — — — — — — — — 18CSB92H* 18CSD92H* 18CSE92H* 18DSB92H* 18DSD92H* 18DSE92H* 18DSF92H* 18ESF92H* 18ESG92H* 18FSF92H* 18FSH92H* 18GSH92H* 18GSJ92H* 18HSJ92H* 18HSK92H* 18ISL92H* 18JTM92H* 18LPT92H* — — — — — — — 2360.00 2360.00 2360.00 2416.00 2416.00 2416.00 2416.00 3067.00 3067.00 3214.00 3214.00 4250.00 4250.00 5285.00 5285.00 6749.00 8214.00 16720.00 — — — — — — — Dual voltage coils not available in modified starters or in starter sizes 5–8. For conduit hubs and conversion instructions, see page 16-87. Enclosure is NEMA Type 4 (painted steel). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18CSB92N* 18CSD92N* 18CSE92N* 18DSB92N* 18DSD92N* 18DSE92N* 18DSF92N* 18ESF92N* 18ESG92N* 18FSF92N* 18FSH92N* 18GSH92N* 18GSJ92N* 18HSJ92N* 18HSK92N* 18ISL92N* 18JTM92N* 18LPT92N* 18LPU92N* 18MPW92N* 18MPX92N* 18NHV92N* 18NHY92N* 18PHZ92N* 18PH192N* List Price $ 1340.00 1340.00 1340.00 1382.00 1382.00 1382.00 1382.00 1512.00 1512.00 1942.00 1942.00 2572.00 2572.00 2760.00 2760.00 5888.00 6233.00 13862.00 13862.00 27676.00 28266.00 37346.00 37346.00 54420.00 54420.00 F coil 100-250V AC 50/60Hz, or DC, H coil 150-500V AC 50/60Hz, or DC Only available F coil 100-250V AC 50/60Hz, or DC For 316 Stainless Steel option see page 16-97. Discount Schedule NEMA Combination Heavy Duty Starters MCP Type with Solid State Overload, Class 18 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Extra Wide Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 4/4X Stainless NEMA 1 200 Volts 1 1 575 Volts NEMA Size Half Size Overload Amp Range 1 5 — 1 5 7 1⁄2 10 15 — 15 25 30 — 30 50 1 5 — 1 5 10 — 15 — 20 25 30 — 30 50 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 18CSB82B* 18CSD82B* 18CSE82B* 18DSB82B* 18DSD82B* 18DSE82B* 18DSF82B* 18ESF82B* 18ESG82B* 18FSF82B* 18FSH82B* 18GSH82B* 18GSJ82B* 18HSJ82B* 18HSK82B* List Price $ 1348.00 1348.00 1348.00 1391.00 1391.00 1391.00 1391.00 1520.00 1520.00 1865.00 1865.00 2623.00 2623.00 2812.00 2812.00 Catalog Number 18CSB82W* 18CSD82W* 18CSE82W* 18DSB82W* 18DSD82W* 18DSE82W* 18DSF82W* 18ESF82W* 18ESG82W* 18FSF82W* 18FSH82W* 18GSH82W* 18GSJ82W* 18HSJ82W* 18HSK82W* List Price $ 2605.00 2605.00 2605.00 2649.00 2649.00 2649.00 2649.00 2779.00 2779.00 3571.00 3571.00 5708.00 5708.00 5897.00 5897.00 List Catalog Number Price $ 18CSB82N* 18CSD82N* 18CSE82N* 18DSB82N* 18DSD82N* 18DSE82N* 18DSF82N* 18ESF82N* 18ESG82N* 18FSF82N* 18FSH82N* 18GSH82N* 18GSJ82N* 18HSJ82N* 18HSK82N* 1727.00 1727.00 1727.00 1770.00 1770.00 1770.00 1770.00 1899.00 1899.00 2330.00 2330.00 3347.00 3347.00 3536.00 3536.00 CONTROL PRODUCTS ⁄2 2 3 1 ⁄2 2 3 7 1⁄2 — 10 — 15 — 20 — 30 460 Volts 16 ⁄2 2 3 1 ⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 230 Volts Motor Circuit Interrupter ETI Amps Catalog Number NEMA 12, NEMA 3/3R, Watertight, Dust-tight NEMA 4 Painted Corrosion Resistant Industrial Use 304 Stainless Steel Weatherproof 316 Stainless Steel (optional) Watertight, Dust-tight General Purpose NEMA & General Purpose Control Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see page 16-87. 316 Stainless Steel option see page 16-97. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-25 Combination Heavy Duty Starters MCP Type with Ambient Compensated Bimetal Overload, Class 18 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (3 required) Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-117. Wiring Diagrams see page 16-131. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure CONTROL PRODUCTS 16 Contactor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size 1 ⁄2 1 3 1 ⁄2 1 3 7 1⁄2 — 10 — 10 10 15 — 25 30 40 1 ⁄2 1 3 1 ⁄2 1 3 7 1⁄2 — 10 — 15 15 20 — 30 40 50 1 3 5 1 3 7 1⁄2 10 15 — 20 25 30 — 30 50 75 100 1 3 5 1 3 7 1⁄2 10 15 — 20 25 30 — 30 50 75 100 18 18 18 27 27 27 27 40 40 45 45 60 60 90 90 115 135 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — Motor Circuit Interrupter ETI Amps 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 125 150 NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 316 Stainless Steel Corrosion Resistant (optional) NEMA 7 & 9 NEMA 3 & 4 NEMA 12,NEMA 3/3R, NEMA 4 Painted Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Catalog Price $ Number List Catalog Price $ Number List Catalog Price $ Number List Price $ Catalog Number List Price $ 18CP92BA*81 18CP92BB*81 18CP92BC*81 18DP92BA*81 18DP92BB*81 18DP92BD*81 18DP92BE*81 18EP92BF*81 18EP92BG*81 18FP92BH*81 18FP92BJ*81 18GP92BK*81 18GP92BL*81 18HP92BM*81 18HP92BN*81 18IP92BP*81 18JP92BR*81 1094.00 1094.00 1094.00 1137.00 1137.00 1137.00 1137.00 1266.00 1266.00 1612.00 1612.00 2154.00 2154.00 2343.00 2343.00 4798.00 5143.00 1922.00 1922.00 1922.00 1965.00 1965.00 1965.00 1965.00 2094.00 2094.00 2886.00 2886.00 4376.00 4376.00 4565.00 4565.00 7641.00 7986.00 2114.00 2114.00 2114.00 2162.00 2162.00 2162.00 2162.00 2304.00 2304.00 3176.00 3176.00 4815.00 4815.00 5023.00 5023.00 8406.00 8786.00 2322.00 2322.00 2322.00 2377.00 2377.00 2377.00 2377.00 3028.00 3028.00 3175.00 3175.00 4212.00 4212.00 5247.00 5247.00 6711.00 8175.00 18CP92NA*81 18CP92NB*81 18CP92NC*81 18DP92NA*81 18DP92NB*81 18DP92ND*81 18DP92NE*81 18EP92NF*81 18EP92NG*81 18FP92NH*81 18FP92NJ*81 18GP92NK*81 18GP92NK*81 18HP92NM*81 18HP92NN*81 18IP92NP*81 18JP92NR*81 1301.00 1301.00 1301.00 1344.00 1344.00 1344.00 1344.00 1473.00 1473.00 1905.00 1905.00 2533.00 2533.00 2722.00 2722.00 5850.00 — 18CP92WA*81 18CP92WB*81 18CP92WC*81 18DP92WA*81 18DP92WB*81 18DP92WD*81 18DP92WE*81 18EP92WF*81 18EP92WG*81 18FP92WH*81 18FP92WJ*81 18GP92WK*81 18GP92WL*81 18HP92WM*81 18HP92WN*81 18IP92WP*81 18JP92WR*81 18CP92FA*81 18CP92FB*81 18CP92FC*81 18DP92FA*81 18DP92FB*81 18DP92FD*81 18DP92FE*81 18EP92FF*81 18EP92FG*81 18FP92FH*81 18FP92FJ*81 18GP92FK*81 18GP92FL*81 18HP92FM*81 18HP92FN*81 18IP92FP*81 18JP92FR*81 18CP92HA*81 18CP92HB*81 18CP92HC*81 18DP92HA*81 18DP92HB*81 18DP92HD*81 18DP92HE*81 18EP92HF*81 18EP92HG*81 18FP92HH*81 18FP92HJ*81 18GP92HK*81 18GP92HL*81 18HP92HM*81 18HP92HN*81 18IP92HP*81 18JP92HR*81 NEMA & General Purpose Control Extra Wide Enclosure, 3-Phase, 3-Pole Max Hp Enclosure NEMA 1 200 Volts 1 ⁄2 1 3 1 ⁄2 1 3 7 1⁄2 — 10 — 10 10 15 — 25 230 Volts 1 ⁄2 1 3 1 ⁄2 1 3 7 1⁄2 — 10 — 15 15 20 — 30 460 Volts 1 3 5 1 3 7 1⁄2 10 15 — 20 25 30 — 30 50 575 Volts 1 3 5 1 3 7 1⁄2 10 15 — 20 25 30 — 30 50 Contactor Amp Rating NEMA Size 18 18 18 27 27 27 27 40 40 45 45 60 60 90 90 0 0 0 1 1 1 1 — — 2 2 — — 3 3 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-26 Half Size Motor Circuit Interrupter ETI Amps — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 NEMA 4/4X Stainless NEMA 12, NEMA 3/3R, Watertight, Dust-tight NEMA 4 Painted Corrosion Resistant Industrial Use 304 Stainless Steel Weatherproof 316 Stainless Steel (optional) Watertight, Dust-tight General Purpose Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 18CP82BA*81 18CP82BB*81 18CP82BC*81 18DP82BA*81 18DP82BB*81 18DP82BD*81 18DP82BE*81 18EP82BF*81 18EP82BG*81 18FP82BH*81 18FP82BJ*81 18GP82BK*81 18GP82BL*81 18HP82BM*81 18HP82BN*81 1309.00 1309.00 1309.00 1353.00 1353.00 1353.00 1353.00 1482.00 1482.00 1826.00 1826.00 1826.00 2584.00 2774.00 2774.00 18CP82WA*81 18CP82WB*81 18CP82WC*81 18DP82WA*81 18DP82WB*81 18DP82WD*81 18DP82WE*81 18EP82WF*81 18EP82WG*81 18FP82WH*81 18FP82WJ*81 18GP82WK*81 18GP82WL*81 18HP82WM*81 18HP82WN*81 2567.00 2567.00 2567.00 2610.00 2610.00 2610.00 2610.00 2739.00 2739.00 3532.00 3532.00 3532.00 5668.00 5859.00 5859.00 18CP82NA*81 18CP82NB*81 18CP82NC*81 18DP82NA*81 18DP82NB*81 18DP82ND*81 18DP82NE*81 18EP82NF*81 18EP82NG*81 18FP82NH*81 18FP82NJ*81 18GP82NK*81 18GP82NL*81 18HP82NM*81 18HP82NN*81 1688.00 1688.00 1688.00 1732.00 1732.00 1732.00 1732.00 1861.00 1861.00 2291.00 2291.00 2291.00 3308.00 3498.00 3498.00 Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see For 316 Stainless Steel option see page 16-97. page 16-87. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Reversing Heavy Duty Starters Solid State Overload with Manual Reset, Class 22 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-104 open and 16-120 enclosed. Wiring Diagrams see page 16-132. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure Open Type NEMA 1 General Purpose Overload 200 230 460 575 NEMA Half Amp Catalog Volts Volts Volts Volts Size Size Range Number 1 1 1 1 ⁄2 2 — 1 ⁄2 2 5 — 1 ⁄2 2 5 10 — 15 — 20 25 30 — 40 50 75 100 200 400 600 900 00 00 00 0 0 0 0 1 1 1 1 1 — — 2 2 — — 3 3 — 4 5 6 7 8 — — — — — — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — — — — — 0.25–1 0.75–3 2.5–10 0.25–1 0.75–3 2.5–10 9–18 0.25–1 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 55–250 160–540 420–820 420–1220 22BSA32A* 598.00 22BSB32A* 598.00 22BSD32A* 598.00 22CSA32A* 702.00 22CSB32A* 702.00 22CSD32A* 702.00 22CSE32A* 702.00 22DSA32A* 789.00 22DSB32A* 789.00 22DSD32A* 789.00 22DSE32A* 789.00 22DSF32A* 789.00 22ESF32A* 1047.00 22ESG32A* 1047.00 22FSF32A* 1461.00 22FSH32A* 1461.00 22GSH32A* 1926.00 22GSJ32A* 1926.00 22HSJ32A* 2399.00 22HSK32A* 2399.00 22ISL32A* 5112.00 22JTM32A* 5802.00 22LPU32A* 11113.00 22MPX32A* 26172.00 22NHY32A* 37088.00 22PHZ32A* 54541.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All Starter Sizes carry one maximum Hp rating. Dual voltage coils not available in size 5–8 starters. For conduit hubs and conversion instructions, see page 16-87. Discount Schedule NEMA Watertight, Dust-tight Corrosion Resistant List Catalog Price $ Number 22BSA32B* 633.00 22BSB32B* 633.00 22BSD32B* 633.00 22CSA32B* 737.00 22CSB32B* 737.00 22CSD32B* 737.00 22CSE32B* 737.00 22DSA32B* 840.00 22DSB32B* 840.00 22DSD32B* 840.00 22DSE32B* 840.00 22DSF32B* 840.00 22ESF32B* 1098.00 22ESG32B* 1098.00 22FSF32B* 1598.00 22FSH32B* 1598.00 22GSH32B* 2115.00 22GSJ32B* 2115.00 22HSJ32B* 2640.00 22HSK32B* 2640.00 22ISL32B* 5561.00 22JTM32B* 6250.00 22LPU32B* 13707.00 22MPX32B* 30480.00 22NHY32B* 41395.00 22PHZ32B* 58849.00 Use Size 0 Use Size 0 Use Size 0 22CSA32W* 22CSB32W* 22CSD32W* 22CSE32W* 22DSA32W* 22DSB32W* 22DSD32W* 22DSE32W* 22DSF32W* 22ESF32W* 22ESG32W* 22FSF32W* 22FSH32W* 22GSH32W* 22GSJ32W* 22HSJ32W* 22HSK32W* 22ISL32W* 22JTM32W* 22LPU32E* 22MPX32E* — — F coil 100-250V AC 50/60Hz, or DC H coil 150-500V AC 50/60Hz, or DC Div 1 and Div 2 Class I Groups C & D Industrial Use Weatherproof Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use List Price $ Catalog Number List Catalog Price $ Number List Catalog Price $ Number List Price $ — — — 1133.00 1133.00 1133.00 1133.00 1391.00 1391.00 1391.00 1391.00 1391.00 1650.00 1650.00 2494.00 2494.00 3227.00 3227.00 3968.00 3968.00 7903.00 8594.00 16739.00 34788.00 — — Use Size 0 Use Size 0 Use Size 0 22CSA32F* 22CSB32F* 22CSD32F* 22CSE32F* 22DSA32F* 22DSB32F* 22DSD32F* 22DSE32F* 22DSF32F* 22ESF32F* 22ESG32F* 22FSF32F* 22FSH32F* 22GSH32F* 22GSJ32F* 22HSJ32F* 22HSK32F* 22ISL32F* 22JTM32F* — — — — — — — 1246.00 1246.00 1246.00 1246.00 1531.00 1531.00 1531.00 1531.00 1531.00 1814.00 1814.00 2743.00 2743.00 3549.00 3549.00 4365.00 4365.00 8694.00 9454.00 — — — — — — — 2330.00 2330.00 2330.00 2330.00 2442.00 2442.00 2442.00 2442.00 2442.00 2701.00 2701.00 4054.00 4054.00 5165.00 5165.00 6491.00 6491.00 11730.00 12418.00 — — — — — — — 891.00 891.00 891.00 891.00 995.00 995.00 995.00 995.00 995.00 1254.00 1254.00 1856.00 1856.00 2528.00 2528.00 3210.00 3210.00 6440.00 7128.00 15127.00 33665.00 43721.00 61175.00 For single phase, select a starter with bimetal OL on page 16-28. only NEMA 4 (painted steel). Enclosure is rated Only available NEMA 12 NEMA 3/3R Use Size 0 Use Size 0 Use Size 0 22CSA32H* 22CSB32H* 22CSD32H* 22CSE32H* 22DSA32H* 22DSB32H* 22DSD32H* 22DSE32H* 22DSF32H* 22ESF32H* 22ESG32H* 22FSF32H* 22FSH32H* 22GSH32H* 22GSJ32H* 22HSJ32H* 22HSK32H* 22ISL32H* 22JTM32H* — — — — Use Size 0 Use Size 0 Use Size 0 22CSA320* 22CSB320* 22CSD320* 22CSE320* 22DSA320* 22DSB320* 22DSD320* 22DSE320* 22DSF320* 22ESF320* 22ESG320* 22FSF320* 22FSH320* 22GSH320* 22GSJ320* 22HSJ320* 22HSK320* 22ISL320* 22JTM320* 22LPU320* 22MPX320* 22NHY320* 22PHZ320* Only available F coil 100-250V AC 50/60Hz, or DC contacts 22B-22E 4th pole built-in 22F-22J 2 NO & 2 NC Auxiliary Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-27 NEMA & General Purpose Control ⁄3 11⁄2 2 1 ⁄3 1 1⁄2 5 — 1 ⁄3 1 1⁄2 5 10 — 15 — 15 25 30 — 30 50 75 100 200 400 600 900 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel NEMA 7 & 9 NEMA 3 & 4 CONTROL PRODUCTS ⁄6 ⁄4 11⁄2 1 ⁄6 3 ⁄4 2 3 1 ⁄6 3 ⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 30 40 50 100 200 300 450 3 NEMA 4X Fiberglass 16 ⁄6 ⁄2 11⁄2 1 ⁄6 1 ⁄2 2 3 1 ⁄6 1 ⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 75 150 — — 1 List Catalog Price $ Number NEMA 4/4X Stainless Reversing Heavy Duty Starters Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 22 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. Single phase starters require 1 heater element. 3-phase starters require 3 heater elements. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-104 open and 16-120 enclosed. Wiring Diagrams see page 16-132. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure Open Type NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant Indoor/Outdoor Use NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3R Div 1 and Div 2 Class I Groups C & D Industrial Use Weatherproof CONTROL PRODUCTS 16 Class II Groups E, F & G Class III Contactor 200 230 460 575 Amp NEMA Half Catalog Volts Volts Volts Volts Rating Size Size Number List Catalog Price $ Number List Catalog Price $ Number 1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 561.00 664.00 750.00 1008.00 1422.00 1887.00 2360.00 5075.00 5763.00 595.00 698.00 801.00 1060.00 1559.00 2077.00 2602.00 5522.00 6212.00 1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 2 2 5 5 10 10 15 15 25 25 30 30 50 50 75 75 100 100 9 18 27 40 45 60 90 115 135 00 0 1 — 2 — 3 — 4 — — — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — Bolted Enclosures 22BP32A*81 22CP32A*81 22DP32A*81 22EP32A*81 22FP32A*81 22GP32A*81 22HP32A*81 22IP32A*81 22JG32A*81 22BP32B*81 22CP32B*81 22DP32B*81 22EP32B*81 22FP32B*81 22GP32B*81 22HP32B*81 22IP32B*81 22JG32B*81 List Price $ Use Size 0 22CP32W*81 22DP32W*81 22EP32W*81 22FP32W*81 22GP32W*81 22HP32W*81 22IP32W*81 22JG32W*81 — 1094.00 1353.00 1612.00 2456.00 3187.00 3928.00 7866.00 8554.00 Catalog Number List Catalog Price $ Number List Catalog Price $ Number List Price $ Use Size 0 22CP32F*81 22DP32F*81 22EP32F*81 22FP32F*81 22GP32F*81 22HP32F*81 22IP32F*81 22JG32F*81 — 1203.00 1489.00 1773.00 2702.00 3506.00 4322.00 8653.00 9410.00 — 2291.00 2403.00 2663.00 4014.00 5126.00 6452.00 11691.00 12381.00 — 854.00 957.00 1215.00 1819.00 2490.00 3170.00 6401.00 7090.00 Use Size 0 22CP32H*81 22DP32H*81 22EP32H*81 22FP32H*81 22GP32H*81 22HP32H*81 22IP32H*81 22JG32H*81 Use Size 0 22CP320*81 22DP320*81 22EP320*81 22FP320*81 22GP320*81 22HP320*81 22IP320*81 22JG320*81 Open Type & Standard Width Enclosure, Single Phase, 3-Wire, 2-Pole Max Hp Enclosure Open Type NEMA 1 General Purpose NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight Watertight, Dust-tight NEMA 3 & 4 NEMA 12 NEMA 3/3R Corrosion Resistant 304 Stainless Steel Industrial Use Weatherproof Corrosion Resistant Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G NEMA & General Purpose Control Class III 115 Volts 208/ 230 Volts 1 ⁄3 1 2 3 1 2 3 5 Bolted Enclosures Indoor/Outdoor Use Contactor Amp NEMA Catalog Rating Size Number List Catalog Price $ Number 9 18 27 35 521.00 625.00 711.00 969.00 00 0 1 1P 22BP12A*81 22CP12A*81 22DP12A*81 22EP12A*81 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All Starter Sizes carry one maximum Hp rating. 16-28 List Catalog Price $ Number 22BP12B*81 555.00 22CP12B*81 658.00 22DP12B*81 762.00 22EP12B*81 1021.00 List Price $ Use Size 0 — 22CP12W*81 1055.00 22DP12W*81 1314.00 22EP12W*81 1572.00 Catalog Number List Catalog Price $ Number List Catalog Price $ Number Use Size 0 22CP12F*81 22DP12F*81 22EP12F*81 — 1162.00 1446.00 1730.00 — 1162.00 1446.00 1730.00 For conduit hubs and conversion instructions, see page 16-87. Coil D, F, or G will be wired for Incoming Voltage. J coil will be wired for 24V separate source. Coils E, H, and L do not apply to single phase starters. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Use Size 0 22CP12H*81 22DP12H*81 22EP12H*81 Use Size 0 22CP120*81 22DP120*81 22EP120*81 List Price $ — 814.00 917.00 1176.00 Auxiliary contacts 22B-22E 4th pole built-in 22F-22J 2 NO & 2 NC Discount Schedule NEMA Combination Reversing Heavy Duty Starters Non-Fusible, Class 25 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (3 required) Fuse clips see page 16-95. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page16-122. Wiring Diagrams see page16-133. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole Max Hp Enclosure 575 Volts NEMA Size Half Size Amp Range 1 1 1 ⁄3 1 1⁄2 5 — 1 ⁄3 1 1⁄2 5 10 — 15 — 15 25 30 — 30 50 75 100 200 400 600 900 1 ⁄2 2 5 — 1 ⁄2 2 5 10 — 15 — 20 25 30 — 40 50 75 100 200 400 600 900 0 0 0 0 1 1 1 1 1 — — 2 2 — — 3 3 — 4 5 6 7 8 — — — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — — — — — 0.25–1 0.75–3 2.5–10 9–18 0.25–1 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 55–250 160–540 420–820 420–1220 30 30 30 30 30 30 30 30 60 60 60 60 60 100 100 100 100 200 200 400 800 1200 1600 ⁄6 ⁄2 2 3 1 ⁄6 1 ⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 20 30 40 75 150 — — 1 ⁄6 ⁄4 2 3 1 ⁄6 3 ⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 25 40 50 100 200 300 450 3 Watertight, Dust-tight Corrosion Resistant NEMA 12 NEMA 3/3R NEMA 4 Painted (thru Sz 4) Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 25CSA92B* 25CSB92B* 25CSD92B* 25CSE92B* 25DSA92B* 25DSB92B* 25DSD92B* 25DSE92B* 25DSF92B* 25ESF92B* 25ESG92B* 25FSF92B* 25FSH92B* 25GSH92B* 25GSJ92B* 25HSJ92B* 25HSK92B* 25ISL92B* 25JTM92B* 25LPU92B* 25MPX92B* 25NHY92B* 25PHZ92B* 1323.00 1323.00 1323.00 1323.00 1409.00 1409.00 1409.00 1409.00 1409.00 1667.00 1667.00 2330.00 2330.00 3364.00 3364.00 3838.00 3838.00 7310.00 7999.00 15576.00 38686.00 52457.00 67132.00 25CSA92W* 25CSB92W* 25CSD92W* 25CSE92W* 25DSA92W* 25DSB92W* 25DSD92W* 25DSE92W* 25DSF92W* 25ESF92W* 25ESG92W* 25FSF92W* 25FSH92W* 25GSH92W* 25GSJ92W* 25HSJ92W* 25HSK92W* 25ISL92W* 25JTM92W* 25LPU92E* 25MPX92E* — — 2373.00 2373.00 2373.00 2373.00 2459.00 2459.00 2459.00 2459.00 2459.00 2718.00 2718.00 3933.00 3933.00 6173.00 6173.00 6646.00 6646.00 10859.00 11548.00 23408.00 42993.00 — — 25CSA92F* 25CSB92F* 25CSD92F* 25CSE92F* 25DSA92F* 25DSB92F* 25DSD92F* 25DSE92F* 25DSF92F* 25ESF92F* 25ESG92F* 25FSF92F* 25FSH92F* 25GSH92F* 25GSJ92F* 25HSJ92F* 25HSK92F* 25ISL92F* 25JTM92F* — — — — 2611.00 2611.00 2611.00 2611.00 2705.00 2705.00 2705.00 2705.00 2705.00 2991.00 2991.00 4326.00 4326.00 6790.00 6790.00 7312.00 7312.00 11946.00 12703.00 — — — — 25CSA92N* 25CSB92N* 25CSD92N* 25CSE92N* 25DSA92N* 25DSB92N* 25DSD92N* 25DSE92N* 25DSF92N* 25ESF92N* 25ESG92N* 25FSF92N* 25FSH92N* 25GSH92N* 25GSJ92N* 25HSJ92N* 25HSK92N* 25ISL92N* 25JTM92N* 25LPU92N* 25MPX92N* 25NHY92N* 25PHZ92N* 1616.00 1616.00 1616.00 1616.00 1702.00 1702.00 1702.00 1702.00 1702.00 1960.00 1960.00 2709.00 2709.00 3864.00 3864.00 4338.00 4338.00 8680.00 9369.00 18833.00 41012.00 54783.00 69459.00 Standard Width Enclosure with Ambient Compensated Bimetal Overload, 3-Phase, 3-Pole Max Hp 200 Volts 3 7 1⁄2 10 10 15 25 30 40 230 Volts 3 7 1⁄2 10 15 20 30 40 50 Enclosure 460 Volts 5 10 15 25 30 50 75 100 575 Volts 5 10 15 25 30 50 75 100 Contactor Amp NEMA Half Rating Size Size 18 0 — 27 1 — 40 — 13⁄4 45 2 — 60 — 21⁄2 90 3 — 115 — 31⁄2 135 4 — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Dual voltage coils not available in modified starters or in starter sizes 5–8. Discount Schedule NEMA Disc Amp Rating 30 30 60 60 100 100 200 200 For NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant Catalog Number 25CP92W*81 25DP92W*81 25EP92W*81 25FP92W*81 25GP92W*81 25HP92W*81 25IP92W*81 25JP92W*81 Catalog Number 25JP92W*81 25DP92F*81 25EP92F*81 25FP92F*81 25GP92F*81 25HP92F*81 25IP92F*81 25JP92F*81 Catalog Number 25CP92B*81 25DP92B*81 25EP92B*81 25FP92B*81 25GP92B*81 25HP92B*81 25IP92B*81 25JP92B*81 List Price $ 1284.00 1370.00 1629.00 2291.00 3325.00 3799.00 7271.00 7673.00 List Price $ 2335.00 2421.00 2680.00 3893.00 6134.00 6608.00 10820.00 11510.00 conduit hubs and conversion instructions, see page 16-87. For 60A disconnect, order fusible cat. no. For 25HP and 200A disconnect, order fusible cat. no. For 30HP and 200A disconnect, order fusible cat. no. For 600A disconnect, order fusible cat. no. NEMA 12 NEMA 3/3R NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ 11510.00 2664.00 2947.00 4284.00 6747.00 7268.00 11903.00 12662.00 Catalog Number 25CP92N*81 25DP92N*81 25EP92N*81 25FP92N*81 25GP92N*81 25HP92N*81 25IP92N*81 25JP92N*81 Enclosure is NEMA Type 4 (painted F coil 100-250V AC 50/60Hz, or DC, List Price $ 1577.00 1663.00 1922.00 2670.00 3825.00 4299.00 8640.00 9329.00 steel). H coil 150-500V AC 50/60Hz, or DC available F coil 100-250V AC 50/60Hz, or DC Only Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-29 NEMA & General Purpose Control 460 Volts NEMA 4X Fiberglass Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel CONTROL PRODUCTS 230 Volts NEMA 4/4X Stainless General Purpose 16 200 Volts Disc Amp Rating NEMA 1 Combination Reversing Heavy Duty Starters MCP Type, Class 26 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (3 required) Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-122. Wiring Diagrams see page 16-133. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole Max Hp Enclosure 200 230 460 575 NEMA Half Volts Volts Volts Volts Size Size NEMA & General Purpose Control CONTROL PRODUCTS 16 1 ⁄2 2 3 1 ⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 50 75 100 150 — — — — 1 ⁄2 2 3 1 ⁄2 2 3 7 1⁄2 — 10 — 15 — 20 — 30 40 50 75 100 125 200 250 300 400 450 1 5 — 1 5 7 1⁄2 10 15 — 15 25 30 — 30 50 75 100 150 200 250 400 500 600 800 900 1 5 — 1 5 10 — 15 — 20 25 30 — 30 50 75 100 200 — 300 400 500 600 800 900 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 5 5 6 6 7 7 8 8 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — — — — — — — — — NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant Interrupter Overload Motor Circuit Catalog Amp ETI Amps Number Range 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 55–250 55–250 160–540 160–540 420–820 420–820 420–1220 420–1220 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 125 150 250 400 400 600 800 1000 1200 1600 26CSB92B* 26CSD92B* 26CSE92B* 26DSB92B* 26DSD92B* 26DSE92B* 26DSF92B* 26ESF92B* 26ESG92B* 26FSF92B* 26FSH92B* 26GSH92B* 26GSJ92B* 26HSJ92B* 26HSK92B* 26ISL92B* 26JTM92B* 26LPT92B* 26LPU92B* 26MPW92B* 26MPX92B* 26NHV92B* 26NHY92B* 26PHZ92B* 26PH192B* List Price $ 1581.00 1581.00 1581.00 1684.00 1684.00 1684.00 1684.00 1942.00 1942.00 2666.00 2666.00 3493.00 3493.00 3968.00 3968.00 8250.00 8939.00 18065.00 18065.00 38646.00 38646.00 52418.00 52418.00 77979.00 77979.00 Catalog Number 26CSB92W* 26CSD92W* 26CSE92W* 26DSB92W* 26DSD92W* 26DSE92W* 26DSF92W* 26ESF92W* 26ESG92W* 26FSF92W* 26FSH92W* 26GSH92W* 26GSJ92W* 26HSJ92W* 26HSK92W* 26ISL92W* 26JTM92W* 26LPT92E* 26LPU92E* 26MPW92E* 26MPX92E* — — — — List Price $ 2632.00 2632.00 2632.00 2735.00 2735.00 2735.00 2735.00 2994.00 2994.00 4268.00 4268.00 6301.00 6301.00 6776.00 6776.00 11799.00 12488.00 27129.00 27129.00 43182.00 43182.00 — — — — Catalog Number 26CSB92F* 26CSD92F* 26CSE92F* 26DSB92F* 26DSD92F* 26DSE92F* 26DSF92F* 26ESF92F* 26ESG92F* 26FSF92F* 26FSH92F* 26GSH92F* 26GSJ92F* 26HSJ92F* 26HSK92F* 26ISL92F* 26JTM92F* — — — — — — — — List Price $ 2896.00 2896.00 2896.00 3009.00 3009.00 3009.00 3009.00 3293.00 3293.00 4696.00 4696.00 6932.00 6932.00 7453.00 7453.00 12979.00 13736.00 — — — — — — — — NEMA 7 & 9 NEMA 3 & 4 Div I and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosure Indoor/Outdoor Use Catalog Number 26CSB92H* 26CSD92H* 26CSE92H* 26DSB92H* 26DSD92H* 26DSE92H* 26DSF92H* 26ESF92H* 26ESG92H* 26FSF92H* 26FSH92H* 26GSH92H* 26GSJ92H* 26HSJ92H* 26HSK92H* 26ISL92H* 26JTM92H* — — — — — — — — List Price $ 3241.00 3241.00 3241.00 3358.00 3358.00 3358.00 3358.00 3488.00 3488.00 4970.00 4970.00 5159.00 5159.00 8265.00 8265.00 11804.00 15846.00 — — — — — — — — NEMA 12 NEMA 3/3R NEMA 4 Painted (thru Sz 4) Industrial Use, Weatherproof, Watertight,Dust-tight Catalog Number 26CSB92N* 26CSD92N* 26CSE92N* 26DSB92N* 26DSD92N* 26DSE92N* 26DSF92N* 26ESF92N* 26ESG92N* 26FSF92N* 26FSH92N* 26GSH92N* 26GSJ92N* 26HSJ92N* 26HSK92N* 26ISL92N* 26JTM92N* 26LPT92N* 26LPU92N* 26MPW92N* 26MPX92N* 26NHV92N* 26NHY92N* 26PHZ92N* 26PH192N* List Price $ 1874.00 1874.00 1874.00 1977.00 1977.00 1977.00 1977.00 2235.00 2235.00 3045.00 3045.00 3993.00 3993.00 4468.00 4468.00 9619.00 10308.00 21321.00 21321.00 41163.00 41163.00 54934.00 54934.00 80305.00 80305.00 Standard Width Enclosure with Ambient Compensated Bimetal Overload, 3-Phase, 3-Pole 1 ⁄2 1 3 1 ⁄2 1 3 7 1⁄2 — 10 — 10 10 15 — 25 30 40 1 ⁄2 1 1 3 3 5 1 ⁄2 1 1 3 3 7 1⁄2 7 1⁄2 10 — 15 10 — — 20 15 25 15 30 20 — — 30 30 50 40 75 50 100 1 3 5 1 3 7 1⁄2 10 15 — 20 25 30 — 30 50 75 100 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 18 18 18 27 27 27 27 40 40 45 45 60 60 90 90 115 135 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 125 150 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-30 26CP92BA*81 26CP92BB*81 26CP92BC*81 26DP92BA*81 26DP92BB*81 26DP92BD*81 26DP92BE*81 26EP92BF*81 26EP92BG*81 26FP92BH*81 26FP92BJ*81 26GP92BK*81 26GP92BL*81 26HP92BM*81 26HP92BN*81 26IP92BP*81 26JP92BR*81 1542.00 1542.00 1542.00 1645.00 1645.00 1645.00 1645.00 1905.00 1905.00 2628.00 2628.00 3454.00 3454.00 3928.00 3928.00 8210.00 8899.00 26CP92WA*81 26CP92WB*81 26CP92WC*81 26DP92WA*81 26DP92WB*81 26DP92WD*81 26DP92WE*81 26EP92WF*81 26EP92WG*81 26FP92WH*81 26FP92WJ*81 26GP92WK*81 26GP92WL*81 26HP92WM*81 26HP92WN*81 26IP92WP*81 26JP92WR*81 2594.00 2594.00 2594.00 2696.00 2696.00 2696.00 2696.00 2955.00 2955.00 4230.00 4230.00 6263.00 6263.00 6738.00 6738.00 11760.00 12449.00 26CP92FA*81 26CP92FB*81 26CP92FC*81 26DP92FA*81 26DP92FB*81 26DP92FD*81 26DP92FE*81 26EP92FF*81 26EP92FG*81 26FP92FH*81 26FP92FJ*81 26GP92FK*81 26GP92FL*81 26HP92FM*81 26HP92FN*81 26IP92FP*81 26JP92FR*81 Dual voltage coils not available in modified starters or in starter sizes 5–8. For conduit hubs and conversion instructions, see page 16-87. Enclosure is NEMA Type 4 (painted steel). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2853.00 2853.00 2853.00 2966.00 2966.00 2966.00 2966.00 3251.00 3251.00 4655.00 4655.00 6891.00 6891.00 7412.00 7412.00 12936.00 13694.00 26CP92HA*81 3204.00 26CP92NA*81 26CP92HB*81 3204.00 26CP92NB*81 26CP92HC*81 3204.00 26CP92NC*81 26DP92HA*81 3320.00 26DP92NA*81 26DP92HB*81 3320.00 26DP92NB*81 26DP92HD*81 3320.00 26DP92ND*81 26DP92HE*81 3320.00 26DP92NE*81 26EP92HF*81 3448.00 26EP92NF*81 26EP92HG*81 3448.00 26EP92NG*81 26FP92HH*81 4931.00 26FP92NH*81 26FP92HJ*81 4931.00 26FP92NJ*81 26GP92HK*81 7752.00 26GP92NK*81 26GP92HL*81 7752.00 26GP92NL*81 26HP92HM*81 8226.00 26HP92NM*81 26HP92HN*81 8226.00 26HP92NN*81 26IP92HP*81 13378.00 26IP92NP*81 26JP92HR*81 15808.00 26JP92NR*81 1835.00 1835.00 1835.00 1938.00 1938.00 1938.00 1938.00 2198.00 2198.00 3007.00 3007.00 3954.00 3954.00 4428.00 4428.00 9580.00 10269.00 F coil 100-250V AC 50/60Hz, or DC, H coil 150-500V AC 50/60Hz, or DC available F coil 100-250V AC 50/60Hz, or DC Only Discount Schedule NEMA Two Speed Heavy Duty Starters Features and Benefits Features ▪ ▪ ▪ ▪ Rugged Industrial Design Dual Voltage, Dual Frequency Coils Compact Design Snap-On Front Removable Auxiliary Contacts ▪ Electrical and Mechanical Interlocks ▪ Half Sizes — Space and Cost Savings ▪ Industrial Type Disconnect Operating Handle ▪ Visible Blade Disconnect Thru Size 4 ▪ Adjustable Motor Circuit Protector ▪ 100,000 Amp Fault Protection with MCP or Class R Fuses ▪ Pilot Device Locations identified on All Enclosures ▪ UL Listed File #E14900 ▪ CSA Certified File #LR6535 Applications Multi-speed magnetic starters automatically reconnect multi-speed motor windings for the desired speed in response to a signal received from push button stations or other pilot devices. half the high speed. Operation Magnetic starters for multi-speed applications select the desired speed in accordance with the pilot control. The shock to machinery upon the reduction of speed is greater than when the speed is increased. Therefore, the pilot control should be wired so that the stop button must be depressed before dropping to a lower speed or time delays should be used for applications requiring full automatic operations. The multi-speed controls are available with the necessary interlocks or relays to provide this type of operation. Acceleration Control provides that the motor be accelerated automatically with timers by progressively energizing the controls from the push button station from the lowest to highest speed. To change to a lower speed the stop button is depressed and then it is necessary to proceed as if starting from rest. Acceleration control can be added from the factory modification section page 16-98. Deceleration Control provides that the motor be decelerated automatically with a timer when going from high speed to low speed. The timer allows the motor to decelerate from high speed to a lower speed before automatically restarting the motor in low speed. Deceleration control can be added from the factory modification section page16-98. These controls may be modified for compelling or acceleration pilot control. Selective Control permits the operator to start the motor at any speed and to change to a higher speed by merely pushing a button. To change to a lower speed it is necessary to first depress the stop button and to then press the proper speed button. Selective control is a function of the pilot control selected and requires no starter modifications. Open Style Two Speed Starter (ESP100 Overload) Starters for separate winding motors consist of a starter unit for each speed. Multi-speed motor starters are available for constant torque, variable torque and constant horsepower motors. Constant Torque motors maintain constant torque at all speeds. Horsepower varies directly with speed. This type of motor is applicable to conveyors, mills and similar applications. Internal View of NEMA 1 Enclosure Sz 2 2S2W starter with CPT (ESP 100 Overload) Open Style Two Speed Starter (Ambient Compensated Overload) Variable Torque motors produce a torque characteristic which varies as the square of the speed. This type of Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-31 NEMA & General Purpose Control Separate Windings motors having separate windings for each speed provide more varied speed combinations in that the low speed need not be one half the high speed. Constant Horsepower motors maintain constant horsepower at all speeds and therefore torque varies inversely with speed. This type of motor is applicable where the same horsepower is required at all speeds. The higher current required at low speed requires derating on starters for constant horsepower applications. This type of motor is applicable to metal working machines such as drills, lathes, mills, bending machines, punch presses, and power wrenches. Compelling Control requires that the motor always be started at the lower speed and that the push buttons be operated in speed sequence to go to the next higher speed. To change to a lower speed, the stop button must be depressed and then the push buttons operated in speed sequence until the desired speed is reached. Compelling control can be added from the factory modification section page 16-98. CONTROL PRODUCTS Consequent Pole multi-speed motors having two speeds on a single winding (consequent pole) require a starter which reconnects the motor leads to half the number of effective motor poles at the high speed point. In this type of motor, the low speed is one motor is applicable to fans, blowers and centrifugal pumps. 16 These starters are available for two speed motors. General Two Speed Heavy Duty Starters Constant or Variable Torque with Solid Overload, Class 30 2S2W starter ( ESP 100 Overload) Ordering Information Coil Table 䊳 Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. 䊳 Replace the (†) with the letter that corresponds to the correct low speed FLA in the FLA table.햳 䊳 Field Modification Kits see page 16-79. 䊳 Factory Modifications see page 16-94. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 䊳 Dimensions see pages 16-104 open and 16-123 enclosed. 䊳 Wiring Diagrams see page 16-134. 䊳 Replacement Parts see page 16-155. Selection Low Speed FLA Table Letter J F A D G L C H E Size 0,1 0,1 0,1 0–13/4 1–4 13/4 2–4 21/2–4 3–4 31/2–4 4 FLA 0.25–1 0.75–3 2.5–10 9–18 13–27 20–40 22–45 30–60 45–90 57–115 67–135 † A B D E F G H J K L M For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant or Variable Torque) Max Hp Enclosure Open Type햴 CONTROL PRODUCTS 16 200 Volts 230 460 575 Volts Volts Volts 1 ⁄2 2 3 1 1⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 3 ⁄4 2 3 1 3⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 30 40 50 1 1⁄2 1 1⁄2 5 5 — — 1 1 ⁄2 1 1⁄2 5 5 10 10 — — 15 15 — — 15 15 25 25 30 30 — — 40 40 50 50 75 75 100 100 NEMA 1 NEMA 4/4X Stainless햲 NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12햲 NEMA 3/3R NEMA Half Size Size Industrial Use Overload Weatherproof Amp Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Range 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 30CSB†32A2V* 30CSD†32A2V* 30CSE†32A2V* 30DSB†32A2V* 30DSD†32A2V* 30DSE†32A2V* 30DSF†32A2V* 30ESF†32A2V* 30ESG†32A2V* 30FSF†32A2V* 30FSH†32A2V* 30GSH†32A2V* 30GSJ†32A2V* 30HSJ†32A2V* 30HSK†32A2V* 30ISL†32A2V* 30JTM†32A2V* 1370.00 1370.00 1370.00 1456.00 1456.00 1456.00 1456.00 1844.00 1844.00 2524.00 2524.00 3145.00 3145.00 3765.00 3765.00 8589.00 9622.00 30CSB†32B2V* 30CSD†32B2V* 30CSE†32B2V* 30DSB†32B2V* 30DSD†32B2V* 30DSE†32B2V* 30DSF†32B2V* 30ESF†32B2V* 30ESG†32B2V* 30FSF†32B2V* 30FSH†32B2V* 30GSH†32B2V* 30GSJ†32B2V* 30HSJ†32B2V* 30HSK†32B2V* 30ISL†32B2V* 30JTM†32B2V* 1405.00 1405.00 1405.00 1508.00 1508.00 1508.00 1508.00 1895.00 1895.00 2680.00 2680.00 3342.00 3342.00 4006.00 4006.00 9536.00 10570.00 30CSB†32W2V* 2231.00 30CSB†32F2V* 30CSD†32W2V* 2231.00 30CSD†32F2V* 30CSE†32W2V* 2231.00 30CSE†32F2V* 30DSB†32W2V* 2317.00 30DSB†32F2V* 30DSD†32W2V* 2317.00 30DSD†32F2V* 30DSE†32W2V* 2317.00 30DSE†32F2V* 30DSF†32W2V* 2317.00 30DSF†32F2V* 30ESF†32W2V* 2705.00 30ESF†32F2V* 30ESG†32W2V* 2705.00 30ESG†32F2V* 30FSF†32W2V* 3679.00 30FSF†32F2V* 30FSH†32W2V* 3679.00 30FSH†32F2V* 30GSH†32W2V* 4600.00 30GSH†32F2V* 30GSJ†32W2V* 4600.00 30GSJ†32F2V* 30HSJ†32W2V* 5487.00 30HSJ†32F2V* 30HSK†32W2V* 5487.00 30HSK†32F2V* 30ISL†32W2V* 12570.00 30ISL†32F2V* 30JTM†32W2V* 13604.00 30JTM†32F2V* 2455.00 2455.00 2455.00 2549.00 2549.00 2549.00 2549.00 2976.00 2976.00 4047.00 4047.00 5061.00 5061.00 6036.00 6036.00 13826.00 14965.00 30CSB†3202V* 1672.00 30CSD†3202V* 1672.00 30CSE†3202V* 1672.00 30DSB†3202V* 1774.00 30DSD†3202V* 1774.00 30DSE†3202V* 1774.00 30DSF†3202V* 1774.00 30ESF†3202V* 2163.00 30ESG†3202V* 2163.00 30FSF†3202V* 3059.00 30FSH†3202V* 3059.00 30GSH†3202V* 3963.00 30GSJ†3202V* 3963.00 30HSJ†3202V* 4868.00 30HSK†3202V* 4868.00 30ISL†3202V* 11243.00 30JTM†3202V* 12277.00 NEMA & General Purpose Control Two Separate Windings, 3-Phase (Constant or Variable Torque) Max Hp Enclosure Open Type햴 NEMA 1 NEMA 4/4X Stainless햲 NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant 30CSB†32W1V* 30CSD†32W1V* 30CSE†32W1V* 30DSB†32W1V* 30DSD†32W1V* 30DSE†32W1V* 30DSF†32W1V* 30ESF†32W1V* 30ESG†32W1V* 30FSF†32W1V* 30FSH†32W1V* 30GSH†32W1V* 30GSJ†32W1V* 30HSJ†32W1V* 30HSK†32W1V* 30ISL†32W1V* 30JTM†32W1V* 30CSB†32F1V* 30CSD†32F1V* 30CSE†32F1V* 30DSB†32F1V* 30DSD†32F1V* 30DSE†32F1V* 30DSF†32F1V* 30ESF†32F1V* 30ESG†32F1V* 30FSF†32F1V* 30FSH†32F1V* 30GSH†32F1V* 30GSJ†32F1V* 30HSJ†32F1V* 30HSK†32F1V* 30ISL†32F1V* 30JTM†32F1V* NEMA 12햲 NEMA 3/3R 200 Volts 230 460 575 Volts Volts Volts NEMA Half Size Size Industrial Use Overload Weatherproof Amp Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Range 1 3 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 ⁄2 2 3 1 1⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 ⁄4 2 3 1 3⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 30 40 50 1 1⁄2 5 — 1 1⁄2 5 10 — 15 — 15 25 30 30 40 50 75 100 1 1⁄2 5 — 1 1⁄2 5 10 — 15 — 15 25 30 30 40 50 75 100 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 30CSB†32A1V* 30CSD†32A1V* 30CSE†32A1V* 30DSB†32A1V* 30DSD†32A1V* 30DSE†32A1V* 30DSF†32A1V* 30ESF†32A1V* 30ESG†32A1V* 30FSF†32A1V* 30FSH†32A1V* 30GSH†32A1V* 30GSJ†32A1V* 30HSJ†32A1V* 30HSK†32A1V* 30ISL†32A1V* 30JTM†32A1V* Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-32 991.00 991.00 991.00 1094.00 1094.00 1094.00 1094.00 1353.00 1353.00 1852.00 1852.00 2343.00 2343.00 2835.00 2835.00 6298.00 6987.00 30CSB†32B1V* 30CSD†32B1V* 30CSE†32B1V* 30DSB†32B1V* 30DSD†32B1V* 30DSE†32B1V* 30DSF†32B1V* 30ESF†32B1V* 30ESG†32B1V* 30FSF†32B1V* 30FSH†32B1V* 30GSH†32B1V* 30GSJ†32B1V* 30HSJ†32B1V* 30HSK†32B1V* 30ISL†32B1V* 30JTM†32B1V* 1026.00 1026.00 1026.00 1147.00 1147.00 1147.00 1147.00 1405.00 1405.00 1991.00 1991.00 2533.00 2533.00 3075.00 3075.00 6745.00 7435.00 햲 For conduit hubs and conversion instructions, see page 16-87. 햳 If motor FLA are unknown, select overload on the 1852.00 1852.00 1852.00 1956.00 1956.00 1956.00 1956.00 2214.00 2214.00 3007.00 3007.00 3782.00 3782.00 4557.00 4557.00 9778.00 10466.00 2037.00 2037.00 2037.00 2151.00 2151.00 2151.00 2151.00 2436.00 2436.00 3308.00 3308.00 4161.00 4161.00 5013.00 5013.00 10756.00 11513.00 30CSB†3201V* 30CSD†3201V* 30CSE†3201V* 30DSB†3201V* 30DSD†3201V* 30DSE†3201V* 30DSF†3201V* 30ESF†3201V* 30ESG†3201V* 30FSF†3201V* 30FSH†3201V* 30GSH†3201V* 30GSJ†3201V* 30HSJ†3201V* 30HSK†3201V* 30ISL†3201V* 30JTM†3201V* 1293.00 1293.00 1293.00 1412.00 1412.00 1412.00 1412.00 1672.00 1672.00 2370.00 2370.00 3153.00 3153.00 3911.00 3911.00 8451.00 9140.00 햴 Auxiliary contacts 30C-30E 4th pole built-in 30F-30J 2 NO & 2 NC basis that low speed FLA will be no greater than 50% of high speed FLA. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Two Speed Heavy Duty Starters Constant HP with Solid State Overload, Class 30 2S2W starter ( ESP 100 Overload) Selection Ordering Information Coil Table 䊳 Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. 䊳 Replace the (†) with the letter that corresponds to the correct FLA in High/Low Speed FLA Table.햳 䊳 Field Modification Kits see page 16-79. 䊳 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Factory Modifications see page 16-94. 䊳 Dimensions see pages 16-104 open and 16-123 enclosed. 䊳 Wiring Diagrams see page 16-134. 䊳 Replacement Parts see page 16-155. 햳 High/Low Speed FLA Table Size 0,1 0,1 0,1 0–13/4 1–4 13/4 2–4 21/2–4 3–4 31/2–4 4 Letter J F A D G L C H E FLA 0.25–1 0.75–3 2.5–10 9–18 13–27 20–40 22–45 30–60 45–90 57–115 67–135 † A B D E F G H J K L M For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant Horsepower) Max Hp Enclosure Open Type햴 200 Volts 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant 30CS††32W2H* 30DS††32W2H* 30ES††32W2H* 30FS††32W2H* 30GS††32W2H* 30HS††32W2H* 30IS††32W2H* 30JT††32W2H* 30CS††32F2H* 30DS††32F2H* 30ES††32F2H* 30FS††32F2H* 30GS††32F2H* 30HS††32F2H* 30IS††32F2H* 30JT††32F2H* NEMA 12햲 NEMA 3/3R NEMA Half Size Size Industrial Use Overload Weatherproof Amp Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Range 0 1 — 2 — 3 — 4 — — — — — — — — — — 13⁄4 — 21⁄2 — 31⁄2 — 30CS††32A2H* 30DS††32A2H* 30ES††32A2H* 30FS††32A2H* 30GS††32A2H* 30HS††32A2H* 30IS††32A2H* 30JT††32A2H* 1370.00 1456.00 1844.00 2524.00 3145.00 3765.00 8589.00 9622.00 30CS††32B2H* 1405.00 30DS††32B2H* 1508.00 30ES††32B2H* 1895.00 30FS††32B2H* 2680.00 30GS††32B2H* 3342.00 30HS††32B2H* 4006.00 30IS††32B2H* 9536.00 30JT††32B2H* 10570.00 2231.00 2317.00 2705.00 3679.00 4600.00 5487.00 12570.00 13604.00 2455.00 2549.00 2976.00 4047.00 5061.00 6036.00 13826.00 14965.00 30CS††3202H* 1672.00 30DS††3202H* 1774.00 30ES††3202H* 2163.00 30FS††3202H* 3059.00 30GS††3202H* 3963.00 30HS††3202H* 4868.00 30IS††3202H* 11243.00 30JT††3202H* 12277.00 Two Separate Windings, 3-Phase (Constant Horsepower) Max Hp Enclosure Open Type햴 200 Volts NEMA 4/4X Stainless햲 NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant 30CS††32W1H* 1852.00 30DS††32W1H* 1956.00 30ES††32W1H* 2214.00 30FS††32W1H* 3007.00 30GS††32W1H* 3782.00 30HS††32W1H* 4557.00 30IS††32W1H* 9778.00 30JT††32W1H* 10466.00 30CS††32F1H* 30DS††32F1H* 30ES††32F1H* 30FS††32F1H* 30GS††32F1H* 30HS††32F1H* 30IS††32F1H* 30JT††32F1H* NEMA 12햲 NEMA 3/3R 230 460 575 Volts Volts Volts NEMA Half Size Size Industrial Use Overload Weatherproof Amp Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Range 2 5 7 1⁄2 10 15 25 30 40 0 1 — 2 — 3 — 4 — — — — — — — — 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 — — 13⁄4 — 21⁄2 — 31⁄2 — 30CS††32A1H* 30DS††32A1H* 30ES††32A1H* 30FS††32A1H* 30GS††32A1H* 30HS††32A1H* 30IS††32A1H* 30JT††32A1H* Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 햲 For conduit hubs and conversion instructions, see 991.00 1094.00 1353.00 1852.00 2343.00 2835.00 6298.00 6987.00 30CS††32B1H* 30DS††32B1H* 30ES††32B1H* 30FS††32B1H* 30GS††32B1H* 30HS††32B1H* 30IS††32B1H* 30JT††32B1H* 1026.00 1147.00 1405.00 1991.00 2533.00 3075.00 6745.00 7435.00 햳 First (†) for high speed, second (†) for low speed. Use motor nameplate information to select FLA. If motor FLA are unknown, select overload on the basis that low speed FLA will be no greater than 50% of high speed FLA. 2037.00 2151.00 2436.00 3308.00 4161.00 5013.00 10756.00 11513.00 30CS††3201H* 30DS††3201H* 30ES††3201H* 30FS††3201H* 30GS††3201H* 30HS††3201H* 30IS††3201H* 30JT††3201H* 1293.00 1412.00 1672.00 2370.00 3153.00 3938.00 8451.00 9140.00 햴 Auxiliary contacts 30C-30E 4th pole built-in 30F-30J 2 NO & 2 NC page 16-87. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-33 NEMA & General Purpose Control 2 5 7 1⁄2 7 1⁄2 10 20 25 30 NEMA 1 CONTROL PRODUCTS 2 5 7 1⁄2 10 15 25 30 40 NEMA 4/4X Stainless햲 NEMA 4X Fiberglass General Purpose 16 2 5 7 1⁄2 7 1⁄2 10 20 25 30 230 460 575 Volts Volts Volts NEMA 1 Two Speed Heavy Duty Starters Constant or Variable Torque with Ambient Compensated Bimetal Overload, Class 30Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148 (6 required)��� Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-104 open and 16-123 enclosed. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. 2S2W starter (Amb. Comp. Bimetal OL) One Winding Consequent Pole, 3 Phase (Constant or Variable Torque) Max Hp Enclosure NEMA & General Purpose Control CONTROL PRODUCTS 16 Open Type 200 Volts 230 Volts 460 Volts NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 12 General Purpose Watertight, Dust-tight Watertight, Dust-tight NEMA 3/3R ContCorrosion Resistant Corrosion Resistant Industrial Use actor 304 Stainless Steel Weatherproof 575 Amp NEMA Half Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 3 7 1⁄2 10 10 15 25 30 40 3 7 1⁄2 10 15 20 30 40 50 5 10 15 25 30 50 75 100 5 10 15 25 30 50 75 100 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — 30CP32A2V*81 30DP32A2V*81 30EP32A2V*81 30FP32A2V*81 30GP32A2V*81 30HP32A2V*81 30IP32A2V*81 30JG32A2V*81 1293.00 1379.00 1766.00 2446.00 3067.00 3687.00 8512.00 9546.00 30CP32B2V*81 1326.00 30DP32B2V*81 1430.00 30EP32B2V*81 1819.00 30FP32B2V*81 2602.00 30GP32B2V*81 3266.00 30HP32B2V*81 3928.00 30IP32B2V*81 9459.00 30JG32B2V*81 11211.00 30CP32W2V*81 2154.00 30DP32W2V*81 2240.00 30EP32W2V*81 2628.00 30FP32W2V*81 3600.00 30GP32W2V*81 4523.00 30HP32W2V*81 5410.00 30IP32W2V*81 12492.00 30JG32W2V*81 13525.00 30CP32F2V*81 30DP32F2V*81 30EP32F2V*81 30FP32F2V*81 30GP32F2V*81 30HP32F2V*81 30IP32F2V*81 30JG32F2V*81 2370.00 2464.00 2891.00 3961.00 4976.00 5951.00 13742.00 14878.00 30CP3202V*81 1594.00 30DP3202V*81 1698.00 30EP3202V*81 2084.00 30FP3202V*81 2981.00 30GP3202V*81 3886.00 30HP3202V*81 4789.00 30IP3202V*81 11165.00 30JG3202V*81 12199.00 Two Separate Windings, 3-Phase (Constant or Variable Torque) Max Hp Enclosure 200 Volts 230 Volts Open Type NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 12 General Purpose Watertight, Dust-tight Watertight, Dust-tight NEMA 3/3R ContCorrosion Resistant Corrosion Resistant Industrial Use actor 304 Stainless Steel Weatherproof 460 575 Amp NEMA Half Volts Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 3 7 1⁄2 10 10 15 25 30 40 3 7 1⁄2 10 15 20 30 40 50 5 10 15 25 30 50 75 100 5 10 15 25 30 50 75 100 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — 30CP32A1V*81 30DP32A1V*81 30EP32A1V*81 30FP32A1V*81 30GP32A1V*81 30HP32A1V*81 30IP32A1V*81 30JG32A1V*81 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-34 914.00 1016.00 1275.00 1774.00 2266.00 2756.00 6220.00 6910.00 30CP32B1V*81 30DP32B1V*81 30EP32B1V*81 30FP32B1V*81 30GP32B1V*81 30HP32B1V*81 30IP32B1V*81 30JG32B1V*81 947.00 1068.00 1326.00 1912.00 2456.00 2998.00 6669.00 7357.00 30CP32W1V*81 1774.00 30DP32W1V*81 1877.00 30EP32W1V*81 2137.00 30FP32W1V*81 2928.00 30GP32W1V*81 3704.00 30HP32W1V*81 4479.00 30IP32W1V*81 9701.00 30JG32W1V*81 10390.00 For conduit hubs and conversion instructions, see page 16-87. If motor FLA are unknown, select heater elements on 30CP32F1V*81 30DP32F1V*81 30EP32F1V*81 30FP32F1V*81 30GP32F1V*81 30HP32F1V*81 30IP32F1V*81 30JG32F1V*81 1952.00 2065.00 2352.00 3221.00 4076.00 4928.00 10671.00 11429.00 30CP3201V*81 30DP3201V*81 30EP3201V*81 30FP3201V*81 30GP3201V*81 30HP3201V*81 30IP3201V*81 30JG3201V*81 1215.00 1336.00 1594.00 2291.00 3075.00 3859.00 8374.00 9064.00 Auxiliary contacts 30C-30E 4th pole built-in 30F-30J 2 NO & 2 NC the basis that low speed FLA will be no greater than 50% of high speed FLA. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Two Speed Heavy Duty Starters Constant HP with Ambient Compensated Bimetal Overload, Class 30 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148 (6 required)��� . Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-104 open and 16-123 enclosed. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. 2S2W starter (Amb. Comp. Bimetal OL) One Winding Consequent Pole, 3-Phase (Constant Horsepower) Max Hp Enclosure 200 Volts Open Type NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 12 General Purpose Watertight, Dust-tight Watertight, Dust-tight NEMA 3/3R ContCorrosion Resistant Corrosion Resistant Industrial Use actor 304 Stainless Steel Weatherproof 230 460 575 Amp NEMA Half Volts Volts Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 2 5 7 1⁄2 7 1⁄2 10 20 25 30 2 5 7 1⁄2 10 15 25 30 40 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — 30CP32A2H*81 30DP32A2H*81 30EP32A2H*81 30FP32A2H*81 30GP32A2H*81 30HP32A2H*81 30IP32A2H*81 30JG32A2H*81 1293.00 1379.00 1766.00 2446.00 3067.00 3687.00 8512.00 9546.00 30CP32B2H*81 1326.00 30DP32B2H*81 1430.00 30EP32B2H*81 1819.00 30FP32B2H*81 2602.00 30GP32B2H*81 3266.00 30HP32B2H*81 3928.00 30IP32B2H*81 9459.00 30JG32B2H*81 10493.00 30CP32W2H*81 2154.00 30CP32F2H*81 2370.00 30CP3202H*81 1594.00 30DP32W2H*81 2240.00 30DP32F2H*81 2464.00 30DP3202H*81 1698.00 30EP32W2H*81 2628.00 30EP32F2H*81 2891.00 30EP3202H*81 2084.00 30FP32W2H*81 3600.00 30FP32F2H*81 3961.00 30FP3202H*81 2981.00 30GP32W2H*81 4523.00 30GP32F2H*81 4976.00 30GP3202H*81 3886.00 30HP32W2H*81 5410.00 30HP32F2H*81 5951.00 30HP3202H*81 4789.00 30IP32W2H*81 12492.00 30IP32F2H*81 13742.00 30IP3202H*81 11165.00 30JG32W2H*81 13525.00 30JG32F2H*81 14878.00 30JG3202H*81 12199.00 16 Two Separate Windings, 3-Phase (Constant Horsepower) Max Hp Enclosure NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 12 General Purpose Watertight, Dust-tight Watertight, Dust-tight NEMA 3/3R ContCorrosion Resistant Corrosion Resistant Industrial Use actor 304 Stainless Steel Weatherproof 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 2 5 7 1⁄2 10 15 25 30 40 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — 30CP32A1H*81 30DP32A1H*81 30EP32A1H*81 30FP32A1H*81 30GP32A1H*81 30HP32A1H*81 30IP32A1H*81 30JG32A1H*81 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 914.00 1016.00 1275.00 1774.00 2266.00 2756.00 6220.00 6910.00 30CP32B1H*81 30DP32B1H*81 30EP32B1H*81 30FP32B1H*81 30GP32B1H*81 30HP32B1H*81 30IP32B1H*81 30JG32B1H*81 947.00 1068.00 1068.00 1912.00 2456.00 2998.00 6669.00 7357.00 30CP32W1H*81 1774.00 30DP32W1H*81 1877.00 30EP32W1H*81 2137.00 30FP32W1H*81 2928.00 30GP32W1H*81 3704.00 30HP32W1H*81 4479.00 30IP32W1H*81 9701.00 30JG32W1H*81 10390.00 If motor FLA are unknown, select heater element on the basis that low speed FLA will be no greater than 50% of high speed FLA. 30CP32F1H*81 1952.00 30CP3201H*81 30DP32F1H*81 2065.00 30DP3201H*81 30EP32F1H*81 2352.00 30EP3201H*81 30FP32F1H*81 3221.00 30FP3201H*81 30GP32F1H*81 4076.00 30GP3201H*81 30HP32F1H*81 4928.00 30HP3201H*81 30IP32F1H*81 10671.00 30IP3201H*81 30JG32F1H*81 11429.00 30JG3201H*81 1215.00 1336.00 1594.00 2291.00 3075.00 3859.00 8374.00 9064.00 Auxiliary contacts 30C-30E 4th pole built-in 30F-30J 2 NO & 2 NC For conduit hubs and conversion instructions, see page 16-87. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-35 NEMA & General Purpose Control 2 5 7 1⁄2 7 1⁄2 10 20 25 30 CONTROL PRODUCTS Open Type Combination Two Speed Heavy Duty Starters Non-Fusible, Constant or Variable Torque with Solid Overload, Class 32 Ordering Information Coil Table 䊳 60Hz Voltage 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Replace the (†) with the letter that corresponds to the correct low speed FLA in the FLA table.��� Fuse clips see page 16-95. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-124. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. Selection Low Speed FLA Table Letter 24 Separate Control 120 Separate Control 110–120/220–240��� 200–208 220–240 277 220–240/440–480��� 440–480 575–600 J F A D G L C H E Size FLA † 0,1 0,1 0,1 0–13/4 1–4 13/4 2–4 21/2–4 3–4 31/2–4 4 0.25–1 0.75–3 2.5–10 9–18 13–27 20–40 22–45 30–60 45–90 57–115 67–135 A B D E F G H J K L M For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant or Variable Torque) Max Hp Enclosure 200 230 Volts Volts CONTROL PRODUCTS 16 1 ⁄2 2 3 1 1⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 20 30 40 3 ⁄4 2 3 1 3⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 25 40 50 460 Volts 575 Volts 1 1⁄2 5 — 1 1⁄2 5 10 — 15 — 15 25 30 — 40 50 75 100 2 5 — 2 5 10 — 15 — 15 25 30 — 40 50 75 100 NEMA Size 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant 32CSB†92W2V2* 32CSD†92W2V2* 32CSE†92W2V2* 32DSB†92W2V2* 32DSB†92W2V2* 32DSE†92W2V2* 32DSF†92W2V2* 32ESF†92W2V2* 32ESG†92W2V2* 32FSF†92W2V2* 32FSH†92W2V2* 32GSH†92W2V2* 32GSJ†92W2V2* 32HSJ†92W2V2* 32HSK†92W2V2* 32ISL†92W2V2* 32JTM†92W2V2* 32CSB†92F2V2* 32CSD†92F2V2* 32CSE†92F2V2* 32DSB†92F2V2* 32DSB†92F2V2* 32DSE†92F2V2* 32DSF†92F2V2* 32ESF†92F2V2* 32ESG†92F2V2* 32FSF†92F2V2* 32FSH†92F2V2* 32GSH†92F2V2* 32GSJ†92F2V2* 32HSJ†92F2V2* 32HSK†92F2V2* 32ISL†92F2V2* 32JTM†92F2V2* Overload Disc Half Amp Amp Size Range Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 30 30 30 30 30 30 60 60 60 60 60 100 100 100 100 200 200 32CSB†92B2V2* 32CSD†92B2V2* 32CSE†92B2V2* 32DSB†92B2V2* 32DSD†92B2V2* 32DSE†92B2V2* 32DSF†92B2V2* 32ESF†92B2V2* 32ESG†92B2V2* 32FSF†92B2V2* 32FSH†92B2V2* 32GSH†92B2V2* 32GSJ†92B2V2* 32HSJ†92B2V2* 32HSK†92B2V2* 32ISL†92B2V2* 32JTM†92B2V2* 2214.00 2214.00 2214.00 2317.00 2317.00 2317.00 2317.00 2928.00 2928.00 3713.00 3713.00 4652.00 4652.00 5315.00 5315.00 11345.00 12381.00 3541.00 3541.00 3541.00 3645.00 3645.00 3645.00 3645.00 4256.00 4256.00 5368.00 5368.00 6306.00 6306.00 8141.00 8141.00 15791.00 16825.00 NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 3894.00 3894.00 3894.00 4009.00 4009.00 4009.00 4009.00 4682.00 4682.00 5904.00 5904.00 6936.00 6936.00 8955.00 8955.00 17371.00 18508.00 2498.00 2498.00 2498.00 2602.00 2602.00 2602.00 2602.00 3214.00 3214.00 4161.00 4161.00 5100.00 5100.00 6298.00 6298.00 14086.00 15120.00 32CSB†92N2V2* 32CSD†92N2V2* 32CSE†92N2V2* 32DSB†92N2V2* 32DSD†92N2V2* 32DSE†92N2V2* 32DSF†92N2V2* 32ESF†92N2V2* 32ESG†92N2V2* 32FSF†92N2V2* 32FSH†92N2V2* 32GSH†92N2V2* 32GSJ†92N2V2* 32HSJ†92N2V2* 32HSK†92N2V2* 32ISL†92N2V2* 32JTM†92N2V2* Two Separate Windings, 3-Phase (Constant or Variable Torque) NEMA & General Purpose Control Max Hp Enclosure 200 230 Volts Volts 1 ⁄2 2 3 1 1⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 20 30 40 3 ⁄4 2 3 1 3⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 25 40 50 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant 460 Volts 575 Volts NEMA Size Overload Disc Half Amp Amp Size Range Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number 1 1⁄2 5 — 1 1⁄2 5 10 — 15 — 15 25 30 — 40 50 75 100 2 5 — 2 5 10 — 15 — 15 25 30 — 40 50 75 100 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-36 NEMA 1 30 30 30 30 30 30 60 60 60 60 60 100 100 100 100 200 200 32CSB†92B1V2* 32CSD†92B1V2* 32CSE†92B1V2* 32DSB†92B1V2* 32DSD†92B1V2* 32DSE†92B1V2* 32DSF†92B1V2* 32ESF†92B1V2* 32ESG†92B1V2* 32FSF†92B1V2* 32FSH†92B1V2* 32GSH†92B1V2* 32GSJ†92B1V2* 32HSJ†92B1V2* 32HSK†92B1V2* 32ISL†92B1V2* 32JTM†92B1V2* 1835.00 1835.00 1835.00 1956.00 1956.00 1956.00 1956.00 2438.00 2438.00 3024.00 3024.00 3842.00 3842.00 4388.00 4388.00 8554.00 9243.00 32CSB†92W1V2* 32CSD†92W1V2* 32CSE†92W1V2* 32DSB†92W1V2* 32DSD†92W1V2* 32DSE†92W1V2* 32DSF†92W1V2* 32ESF†92W1V2* 32ESG†92W1V2* 32FSF†92W1V2* 32FSH†92W1V2* 32GSH†92W1V2* 32GSJ†92W1V2* 32HSJ†92W1V2* 32HSK†92W1V2* 32ISL†92W1V2* 32JTM†92W1V2* 3162.00 3162.00 3162.00 3282.00 3282.00 3282.00 3282.00 3765.00 3765.00 4678.00 4678.00 5496.00 5496.00 7210.00 7210.00 13000.00 13690.00 Dual voltage coils not available in modified starters. conduit hubs and conversion instructions, see page 16-87. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 32CSB†92F1V2* 32CSD†92F1V2* 32CSE†92F1V2* 32DSB†92F1V2* 32DSD†92F1V2* 32DSE†92F1V2* 32DSF†92F1V2* 32ESF†92F1V2* 32ESG†92F1V2* 32FSF†92F1V2* 32FSH†92F1V2* 32GSH†92F1V2* 32GSJ†92F1V2* 32HSJ†92F1V2* 32HSK†92F1V2* 32ISL†92F1V2* 32JTM†92F1V2* NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 3478.00 3478.00 3478.00 3611.00 3611.00 3611.00 3611.00 4142.00 4142.00 5146.00 5146.00 6046.00 6046.00 7932.00 7932.00 14300.00 15059.00 2119.00 2119.00 2119.00 2240.00 2240.00 2240.00 2240.00 2722.00 2722.00 3472.00 3472.00 4290.00 4290.00 5368.00 5368.00 11294.00 11984.00 32CSB†92N1V2* 32CSD†92N1V2* 32CSE†92N1V2* 32DSB†92N1V2* 32DSD†92N1V2* 32DSE†92N1V2* 32DSF†92N1V2* 32ESF†92N1V2* 32ESG†92N1V2* 32FSF†92N1V2* 32FSH†92N1V2* 32GSH†92N1V2* 32GSJ†92N1V2* 32HSJ†92N1V2* 32HSK†92N1V2* 32ISL†92N1V2* 32JTM†92N1V2* If motor FLA are unknown, select overload on the basis that low speed FLA will be no greater than 50% of high speed FLA. Discount Schedule NEMA Combination Two Speed Heavy Duty Starters Non-Fusible, Constant Horsepower with Solid State Overload, Class 32 High/Low Speed FLA Table Coil Table Ordering Information Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. 䊳 Replace the (†) with the letter that corresponds to the correct FLA in the High/Low Speed FLA Table. 䊳 Fuse clips see page 16-95. 䊳 Field Modification Kits see page 16-79. 䊳 Factory Modifications see page 16-94. 䊳 Dimensions see page 16-124. 䊳 Wiring Diagrams see page 16-134. 䊳 Replacement Parts see page 16-155. 䊳 Selection 60Hz Voltage Letter 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 J F A D G L C H E Size 0,1 0,1 0,1 0–13⁄4 1–4 13⁄4 2–4 21⁄2–4 3–4 31⁄2–4 4 FLA 0.25–1 0.75–3 2.5–10 9–18 13–27 20–40 22–45 30–60 45–90 57–115 67–135 † A B D E F G H J K L M For other voltages and frequencies see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant Horsepower) Max Hp Enclosure 200 230 Volts Volts 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight NEMA Size Overload Disc Half Amp Amp Size Range Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — 3894.00 4679.00 4679.00 5904.00 6936.00 8955.00 17371.00 18508.00 2498.00 2602.00 3214.00 4161.00 5100.00 6298.00 14086.00 15120.00 — — — — — — — — 30 30 60 60 100 100 200 200 32CS††92B2H2* 2214.00 32CS††92W2H2* 3541.00 32CS††92F2H2* 32DS††92B2H2* 2317.00 32DS††92W2H2* 3645.00 32DS††92F2H2* 32ES††92B2H2* 2928.00 32ES††92W2H2* 4256.00 32ES††92F2H2* 32FS††92B2H2* 3713.00 32FS††92W2H2* 5368.00 32FS††92F2H2* 32GS††92B2H2* 4652.00 32GS††92W2H2* 6306.00 32GS††92F2H2* 32HS††92B2H2* 5315.00 32HS††92W2H2* 8141.00 32HS††92F2H2* 32IS††92B2H2* 11345.00 32IS††92W2H2* 15791.00 32IS††92F2H2* 32JT††92B2H2* 12381.00 32JT††92W2H2* 16825.00 32JT††92F2H2* 32CS††92N2H2* 32DS††92N2H2* 32ES††92N2H2* 32FS††92N2H2* 32GS††92N2H2* 32HS††92N2H2* 32IS††92N2H2* 32JT††92N2H2* Two Separate Windings, 3-Phase (Constant Horsepower) Max Hp Enclosure 2 5 7 1⁄2 10 15 25 30 40 460 Volts 575 Volts 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight NEMA Size Overload Disc Half Amp Amp Size Range Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — 3478.00 3611.00 4142.00 5146.00 6046.00 7932.00 14300.00 15059.00 2119.00 2240.00 2722.00 3472.00 4290.00 5368.00 11294.00 11984.00 — — — — — — — — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA 30 30 60 60 100 100 200 200 32CS††92B1H2* 32DS††92B1H2* 32ES††92B1H2* 32FS††92B1H2* 32GS††92B1H2* 32HS††92B1H2* 32IS††92B1H2* 32JT††92B1H2* Dual 1835.00 1956.00 2438.00 3024.00 3842.00 4388.00 8554.00 9243.00 32CS††92W1H2* 32DS††92W1H2* 32ES††92W1H2* 32FS††92W1H2* 32GS††92W1H2* 32HS††92W1H2* 32IS††92W1H2* 32JT††92W1H2* 3162.00 3282.00 3765.00 4678.00 5496.00 7210.00 13000.00 13690.00 voltage coils not available in modified starters. conduit hubs and conversion instructions, see page 16-87. For 32CS††92F1H2* 32DS††92F1H2* 32ES††92F1H2* 32FS††92F1H2* 32GS††92F1H2* 32HS††92F1H2* 32IS††92F1H2* 32JT††92F1H2* 32CS††92N1H2* 32DS††92N1H2* 32ES††92N1H2* 32FS††92N1H2* 32GS††92N1H2* 32HS††92N1H2* 32IS††92N1H2* 32JT††92N1H2* First † for high speed, second † for low speed. Use motor nameplate information to select FLA. If motor FLA are unknown, select overload on the basis that low speed FLA will be no greater than 50% of high speed FLA. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-37 NEMA & General Purpose Control 200 230 Volts Volts 2 5 7 1⁄2 7 1⁄2 10 20 25 30 CONTROL PRODUCTS 2 5 7 1⁄2 10 15 25 30 40 575 Volts NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose 16 2 5 7 1⁄2 7 1⁄2 10 20 25 30 460 Volts NEMA 1 Combination Two Speed Heavy Duty Starters Non-Fusible, Constant or Variable Torque with Ambient Compensated Bimetal Overload, Class 32 Selection Ordering Information Coil Table 䊳 60Hz Voltage Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. 䊳 Heater elements see page 16-148. (6 required) 䊳 Fuse clips see page 16-95. 䊳 Field Modification Kits see page 16-79. 䊳 Factory Modifications see page 16-94. 䊳 Dimensions see page 16-124. 䊳 Wiring Diagrams see page 16-134. 䊳 Replacement Parts see page 16-155. Letter 24 Separate Control 120 Separate Control 110–120/220–240��� J F A 200–208 D 220–240 G 277 L ��� 220–240/440–480 C 440–480 H 575–600 E For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant or Variable Torque) Max Hp Enclosure CONTROL PRODUCTS 16 200 230 Volts Volts 3 7 1⁄2 10 10 15 20 30 40 3 7 1⁄2 10 15 20 25 40 50 575 Volts 5 10 15 25 30 50 75 100 5 10 15 25 30 50 75 100 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant Disc Amp Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number 30 30 60 60 100 100 200 200 32CP92B2V2*81 2137.00 32CP92W2V2*81 3463.00 32CP92F2V2*81 32DP92B2V2*81 2240.00 32DP92W2V2*81 3566.00 32DP92F2V2*81 32EP92B2V2*81 2852.00 32EP92W2V2*81 4178.00 32EP92F2V2*81 32FP92B2V2*81 3635.00 32FP92W2V2*81 5289.00 32FP92F2V2*81 32GP92B2V2*81 4575.00 32GP92W2V2*81 6229.00 32GP92F2V2*81 32HP92B2V2*81 5237.00 32HP92W2V2*81 8064.00 32HP92F2V2*81 32IP92B2V2*81 11269.00 32IP92W2V2*81 15713.00 32IP92F2V2*81 32JP92B2V2*81 12302.00 32JP92W2V2*81 16749.00 32JP92F2V2*81 NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number 3809.00 3923.00 4596.00 5818.00 6851.00 8871.00 17286.00 18423.00 List Price $ 32CP92N2V2*81 32DP92N2V2*81 32EP92N2V2*81 32FP92N2V2*81 32GP92N2V2*81 32HP92N2V2*81 32IP92N2V2*81 32JP92N2V2*81 2421.00 2524.00 3135.00 4083.00 5022.00 6220.00 14008.00 15041.00 Two Separate Windings, 3-Phase (Constant or Variable Torque) Max Hp 200 230 Volts Volts NEMA & General Purpose Control 460 Volts Contactor Amp NEMA Half Rating Size Size NEMA 1 3 7 1⁄2 10 10 15 20 30 40 3 7 1⁄2 10 15 20 25 40 50 Enclosure 460 Volts 5 10 15 25 30 50 75 100 575 Volts 5 10 15 25 30 50 75 100 Contactor Amp NEMA Half Rating Size Size 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-38 NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant 32CP92W1V2*81 32DP92W1V2*81 32EP92W1V2*81 32FP92W1V2*81 32GP92W1V2*81 32HP92W1V2*81 32IP92W1V2*81 32JP92W1V2*81 32CP92F1V2*81 32DP92F1V2*81 32EP92F1V2*81 32FP92F1V2*81 32GP92F1V2*81 32HP92F1V2*81 32IP92F1V2*81 32JP92F1V2*81 Disc Amp Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number 30 30 60 60 100 100 200 200 32CP92B1V2*81 32DP92B1V2*81 32EP92B1V2*81 32FP92B1V2*81 32GP92B1V2*81 32HP92B1V2*81 32IP92B1V2*81 32JP92B1V2*81 1758.00 1877.00 2360.00 2946.00 3765.00 4307.00 8478.00 9166.00 3084.00 3205.00 3687.00 4600.00 5419.00 7134.00 12922.00 13611.00 NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 3393.00 3526.00 4056.00 5061.00 5962.00 7847.00 14215.00 14973.00 2042.00 2163.00 2645.00 3394.00 4213.00 5289.00 11217.00 11906.00 32CP92N1V2*81 32DP92N1V2*81 32EP92N1V2*81 32FP92N1V2*81 32GP92N1V2*81 32HP92N1V2*81 32IP92N1V2*81 32JP92N1V2*81 Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see page 16-87. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Combination Two Speed Heavy Duty Starters Non-Fusible, Constant Horsepower with Ambient Compensated Bimetal Overload, Class 32 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (6 Required) Fuse clips see page 16-95. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-124. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant Horsepower) Max Hp Enclosure 200 230 Volts Volts 2 5 7 1⁄2 7 1⁄2 10 20 25 30 2 5 7 1⁄2 10 15 25 30 40 460 Volts 3 7 1⁄2 10 20 25 40 50 75 575 Volts 3 7 1⁄2 10 20 25 40 50 75 NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant Contactor Disc Amp NEMA Half Amp Rating Size Size Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — 30 30 60 60 100 100 200 200 32CP92B2H2*81 2137.00 32CP92W2H2*81 3463.00 32DP92B2H2*81 2240.00 32DP92W2H2*81 3566.00 32EP92B2H2*81 2852.00 32EP92W2H2*81 4178.00 32FP92B2H2*81 3635.00 32FP92W2H2*81 5289.00 32GP92B2H2*81 4575.00 32GP92W2H2*81 6229.00 32HP92B2H2*81 5237.00 32HP92W2H2*81 8064.00 32IP92B2H2*81 11269.00 32IP92W2H2*81 15713.00 32JP92B2H2*81 12302.00 32JP92W2H2*81 16749.00 32CP92F2H2*81 32DP92F2H2*81 32EP92F2H2*81 32FP92F2H2*81 32GP92F2H2*81 32HP92F2H2*81 32IP92F2H2*81 32JP92F2H2*81 NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 3809.00 3923.00 4596.00 5818.00 6851.00 8860.00 17286.00 18423.00 2421.00 2524.00 3135.00 4083.00 5022.00 6220.00 14008.00 15041.00 32CP92N2H2*81 32DP92N2H2*81 32EP92N2H2*81 32FP92N2H2*81 32GP92N2H2*81 32HP92N2H2*81 32IP92N2H2*81 32JP92N2H2*81 16 Two Separate Windings, 3-Phase (Constant Horsepower) Enclosure 200 230 Volts Volts 2 5 7 1⁄2 10 15 25 30 40 575 Volts 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 18 27 40 45 60 90 115 135 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant 32CP92W1H2*81 32DP92W1H2*81 32EP92W1H2*81 32FP92W1H2*81 32GP92W1H2*81 32HP92W1H2*81 32IP92W1H2*81 32JP92W1H2*81 32CP92F1H2*81 32DP92F1H2*81 32EP92F1H2*81 32FP92F1H2*81 32GP92F1H2*81 32HP92F1H2*81 32IP92F1H2*81 32JP92F1H2*81 Disc Amp Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number 30 30 60 60 100 100 200 200 32CP92B1H2*81 32DP92B1H2*81 32EP92B1H2*81 32FP92B1H2*81 32GP92B1H2*81 32HP92B1H2*81 32IP92B1H2*81 32JP92B1H2*81 1758.00 1877.00 2360.00 2946.00 3765.00 4307.00 8478.00 9166.00 3084.00 3205.00 3687.00 4600.00 5419.00 7134.00 12923.00 13611.00 NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight List Price $ Catalog Number List Price $ 3393.00 3526.00 4056.00 5061.00 5962.00 7847.00 14215.00 14973.00 2042.00 2163.00 2645.00 3394.00 4213.00 5289.00 11217.00 11906.00 32CP92N1H2*81 32DP92N1H2*81 32EP92N1H2*81 32FP92N1H2*81 32GP92N1H2*81 32HP92N1H2*81 32IP92N1H2*81 32JP92N1H2*81 Dual voltage coils not available in modified starters. conduit hubs and conversion instructions, see page 16-87. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-39 NEMA & General Purpose Control 2 5 7 1⁄2 7 1⁄2 10 20 25 30 460 Volts Contactor Amp NEMA Half Rating Size Size NEMA 1 CONTROL PRODUCTS Max Hp Combination Two Speed Heavy Duty Starters MCP Type, Constant or Variable Torque with Solid State Overload, Class 32 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Replace the (†) with the letter that corresponds to the correct low speed FLA in the FLA table. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-124. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Selection Low Speed FLA Table Letter J F A D G L C H E Size 0,1 0,1 0,1 0–13/4 1–4 13/4 2–4 21/2–4 3–4 31/2–4 4 FLA 0.25–1 0.75–3 2.5–10 9–18 13–27 20–40 22–45 30–60 45–90 57–115 67–135 † A B D E F G H J K L M For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant or Variable Torque) Max Hp Enclosure Overload 200 230 460 575 NEMA Half Amp Motor Circuit Volts Volts Volts Volts Size Size Range Interrupter ETI Amps CONTROL PRODUCTS 16 1 ⁄2 2 3 11⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 1 ⁄2 1 2 5 3 — 1 1 ⁄2 1 2 5 3 7 1⁄2 1 7 ⁄2 10 — 15 10 — — 15 15 25 — 30 20 — — 30 30 50 40 75 50 100 1 5 — 1 5 10 — 15 — 20 25 30 — 30 50 75 100 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 32CSB†92B2V* 2619.00 32CSB†92W2V* 3945.00 32CSB†92F2V* 32CSD†92B2V* 2619.00 32CSD†92W2V* 3945.00 32CSD†92F2V* 32CSE†92B2V* 2619.00 32CSE†92W2V* 3945.00 32CSE†92F2V* 32DSB†92B2V* 2722.00 32DSB†92W2V* 4049.00 32DSB†92F2V* 32DSD†92B2V* 2722.00 32DSD†92W2V* 4049.00 32DSD†92F2V* 32DSE†92B2V* 2722.00 32DSE†92W2V* 4049.00 32DSE†92F2V* 32DSF†92B2V* 2722.00 32DSF†92W2V* 4049.00 32DSF†92F2V* 32ESF†92B2V* 3377.00 32ESF†92W2V* 4703.00 32ESF†92F2V* 32ESG†92B2V* 3377.00 32ESG†92W2V* 4703.00 32ESG†92F2V* 32FSF†92B2V* 4161.00 32FSF†92W2V* 5815.00 32FSF†92F2V* 32FSH†92B2V* 4161.00 32FSH†92W2V* 5815.00 32FSH†92F2V* 32GSH†92B2V* 4954.00 32GSH†92W2V* 6608.00 32GSH†92F2V* 32GSJ†92B2V* 4954.00 32GSJ†92W2V* 6608.00 32GSJ†92F2V* 32HSJ†92B2V* 5616.00 32HSJ†92W2V* 8443.00 32HSJ†92F2V* 32HSK†92B2V* 5616.00 32HSK†92W2V* 8443.00 32HSK†92F2V* 32ISL†92B2V* 12483.00 32ISL†92W2V* 16928.00 32ISL†92F2V* 32JTM†92B2V* 13518.00 32JTM†92W2V* 17962.00 32JTM†92F2V* 4340.00 4340.00 4340.00 4455.00 4455.00 4455.00 4455.00 5174.00 5174.00 6397.00 6397.00 7268.00 7268.00 9287.00 9287.00 18621.00 19760.00 2903.00 2903.00 2903.00 3007.00 3007.00 3007.00 3007.00 3661.00 3661.00 4610.00 4610.00 5401.00 5401.00 6599.00 6599.00 15223.00 16256.00 3 10 25 3 10 25 30 40 50 40 50 50 100 100 100 125 150 32CSB†92N2V* 32CSD†92N2V* 32CSE†92N2V* 32DSB†92N2V* 32DSD†92N2V* 32DSE†92N2V* 32DSF†92N2V* 32ESF†92N2V* 32ESG†92N2V* 32FSF†92N2V* 32FSH†92N2V* 32GSH†92N2V* 32GSJ†92N2V* 32HSJ†92N2V* 32HSK†92N2V* 32ISL†92N2V* 32JTM†92N2V* Two Separate Windings, 3-Phase (Constant or Variable Torque) NEMA & General Purpose Control Max Hp Enclosure Overload 200 230 460 575 NEMA Half Amp Motor Circuit Volts Volts Volts Volts Size Size Range Interrupter ETI Amps 1 ⁄2 2 3 1 1⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 1 ⁄2 2 3 1 1⁄2 2 3 7 1⁄2 — 10 — 15 — 20 — 30 40 50 1 5 — 1 5 7 1⁄2 10 15 — 15 25 30 — 30 50 75 100 1 5 — 1 5 10 — 15 — 20 25 30 — 30 50 75 100 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 0.75–3 2.5–10 9–18 0.75–3 2.5–10 9–18 13–27 13–27 20–40 13–27 22–45 22–45 30–60 30–60 45–90 57–115 67–135 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 32CSB†92B1V* 2240.00 32CSD†92B1V* 2240.00 32CSE†92B1V* 2240.00 32DSB†92B1V* 2360.00 32DSD†92B1V* 2360.00 32DSE†92B1V* 2360.00 32DSF†92B1V* 2360.00 32ESF†92B1V* 2886.00 32ESG†92B1V* 2886.00 32FSF†92B1V* 3472.00 32FSH†92B1V* 3472.00 32GSH†92B1V* 4144.00 32GSJ†92B1V* 4144.00 32HSJ†92B1V* 4686.00 32HSK†92B1V* 4686.00 32ISL†92B1V* 9692.00 32JTM†92B1V* 10380.00 3923.00 3923.00 3923.00 4056.00 4056.00 4056.00 4056.00 4634.00 4634.00 5640.00 5640.00 6379.00 6379.00 8264.00 8264.00 15552.00 16310.00 2524.00 2524.00 2524.00 2645.00 2645.00 2645.00 2645.00 3170.00 3170.00 3920.00 3920.00 4592.00 4592.00 5668.00 5668.00 12432.00 13121.00 3 10 25 3 10 25 30 40 50 40 50 50 100 100 100 125 150 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-40 NEMA 1 32CSB†92W1V* 3566.00 32CSB†92F1V* 32CSD†92W1V* 3566.00 32CSD†92F1V* 32CSE†92W1V* 3566.00 32CSE†92F1V* 32DSB†92W1V* 3687.00 32DSB†92F1V* 32DSD†92W1V* 3687.00 32DSD†92F1V* 32DSE†92W1V* 3687.00 32DSE†92F1V* 32DSF†92W1V* 3687.00 32DSF†92F1V* 32ESF†92W1V* 4213.00 32ESF†92F1V* 32ESG†92W1V* 4213.00 32ESG†92F1V* 32FSF†92W1V* 5126.00 32FSF†92F1V* 32FSH†92W1V* 5126.00 32FSH†92F1V* 32GSH†92W1V* 5798.00 32GSH†92F1V* 32GSJ†92W1V* 5798.00 32GSJ†92F1V* 32HSJ†92W1V* 7513.00 32HSJ†92F1V* 32HSK†92W1V* 7513.00 32HSK†92F1V* 32ISL†92W1V* 14137.00 32ISL†92F1V* 32JTM†92W1V* 14827.00 32JTM†92F1V* Dual voltage coils not available in modified starters. conduit hubs and conversion instructions, see page 16-87. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 32CSB†92N1V* 32CSD†92N1V* 32CSE†92N1V* 32DSB†92N1V* 32DSD†92N1V* 32DSE†92N1V* 32DSF†92N1V* 32ESF†92N1V* 32ESG†92N1V* 32FSF†92N1V* 32FSH†92N1V* 32GSH†92N1V* 32GSJ†92N1V* 32HSJ†92N1V* 32HSK†92N1V* 32ISL†92N1V* 32JTM†92N1V* If motor FLA are unknown, select overload on the basis that low speed FLA will be no greater than 50% of high speed FLA. Discount Schedule NEMA Combination Two Speed Heavy Duty Starters MCP Type, Constant Horsepower with Solid State Overload, Class 32 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Ordering Information Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Replace the (†) with the letter that corresponds to the correct FLA in the High/Low Speed FLA table.햴 Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-124. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. 60Hz Voltage Selection High/Low Speed FLA Table햴 Letter 24 Separate Control 120 Separate Control 110–120/220–240햲 200–208 220–240 277 220–240/440–480햲 440–480 575–600 J F A D G L C H E Size 0,1 0,1 0,1 0–13⁄4 1–4 13⁄4 2–4 21⁄2–4 3–4 31⁄2–4 4 FLA 0.25–1 0.75–3 2.5–10 9–18 13–27 20–40 22–45 30–60 45–90 57–115 67–135 † A B D E F G H J K L M For other voltages and frequencies see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant Horsepower) Max Hp Enclosure NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant Overload 200 230 460 575 NEMA Half Amp Motor Circuit Volts Volts Volts Volts Size Size Range Interrupter ETI Amps Catalog Number List Price $ Catalog Number List Price $ Catalog Number 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — — — — — 10 25 40 50 100 100 125 150 32CS††92B2H* 32DS††92B2H* 32ES††92B2H* 32FS††92B2H* 32GS††92B2H* 32HS††92B2H* 32IS††92B2H* 32JT††92B2H* 2619.00 2722.00 3377.00 4161.00 4954.00 5616.00 12483.00 13518.00 32CS††92W2H* 32DS††92W2H* 32ES††92W2H* 32FS††92W2H* 32GS††92W2H* 32HS††92W2H* 32IS††92W2H* 32JT††92W2H* 3945.00 4049.00 4703.00 5815.00 6608.00 8443.00 16928.00 17962.00 32CS††92F2H* 32DS††92F2H* 32ES††92F2H* 32FS††92F2H* 32GS††92F2H* 32HS††92F2H* 32IS††92F2H* 32JT††92F2H* List Price $ Catalog Number List Price $ 4340.00 4455.00 5174.00 6397.00 7268.00 9287.00 18621.00 19760.00 2903.00 3007.00 3661.00 4610.00 5401.00 6599.00 15223.00 16256.00 32CS††92N2H* 32DS††92N2H* 32ES††92N2H* 32FS††92N2H* 32GS††92N2H* 32HS††92N2H* 32IS††92N2H* 32JT††92N2H* Two Separate Windings, 3-Phase (Constant Horsepower) Max Hp Enclosure NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Overload 200 230 460 575 NEMA Half Amp Motor Circuit Volts Volts Volts Volts Size Size Range Interrupter ETI Amps Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 2 5 7 1⁄2 7 1⁄2 10 20 25 30 3923.00 4056.00 4634.00 5640.00 6379.00 8264.00 15552.00 16310.00 2524.00 2645.00 3170.00 3920.00 4592.00 5668.00 12432.00 13121.00 3 7 1⁄2 10 20 25 40 50 75 3 7 1⁄2 10 20 25 40 50 75 0 1 — 2 — 3 — 4 — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — — — — — 10 25 40 50 100 100 125 150 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA 32CS††92B1H* 32DS††92B1H* 32ES††92B1H* 32FS††92B1H* 32GS††92B1H* 32HS††92B1H* 32IS††92B1H* 32JT††92B1H* 햲 햳 2240.00 2360.00 2886.00 3472.00 4144.00 4686.00 9692.00 10380.00 32CS††92W1H* 32DS††92W1H* 32ES††92W1H* 32FS††92W1H* 32GS††92W1H* 32HS††92W1H* 32IS††92W1H* 32JT††92W1H* 3566.00 3687.00 4213.00 5126.00 5798.00 7513.00 14137.00 14827.00 Dual voltage coils not available in modified starters. For conduit hubs and conversion instructions, see page 16-87. 32CS††92F1H* 32DS††92F1H* 32ES††92F1H* 32FS††92F1H* 32GS††92F1H* 32HS††92F1H* 32IS††92F1H* 32JT††92F1H* 햴 Industrial Use Weatherproof Watertight, Dust-tight 32CS††92N1H* 32DS††92N1H* 32ES††92N1H* 32FS††92N1H* 32GS††92N1H* 32HS††92N1H* 32IS††92N1H* 32JT††92N1H* First † for high speed, second † for low speed. Use motor nameplate information to select FLA. If motor FLA are unknown, select overload on the basis that low speed FLA will be no greater than 50% of high speed FLA. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-41 NEMA & General Purpose Control 2 5 7 1⁄2 10 15 25 30 40 CONTROL PRODUCTS 2 5 7 1⁄2 10 15 25 30 40 Industrial Use Weatherproof Watertight, Dust-tight 16 2 5 7 1⁄2 7 1⁄2 10 20 25 30 NEMA 12, NEMA 3/3R��� NEMA 4 Painted Combination Two Speed Heavy Duty Starters MCP Type, Constant or Variable Torque w/Ambient Compensated Bimetal Overload, Class 32 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (6 Required) Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-124. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant or Variable Torque) Max Hp Enclosure 200 230 460 575 NEMA Half Motor Circuit Volts Volts Volts Volts Size Size Interrupter ETI Amps CONTROL PRODUCTS 16 1 ⁄2 1 3 1 1⁄2 1 3 7 1⁄2 — 10 — 10 10 15 — 25 30 40 1 ⁄2 1 1 1 3 3 3 5 5 1 1 ⁄2 1 1 1 3 3 1 7 1⁄2 3 7 ⁄2 1 7 ⁄2 10 10 — 15 15 10 — — — 20 20 15 25 25 15 30 30 20 — — — 30 30 30 50 50 40 75 75 50 100 100 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 125 150 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 32CP92B2VA*81 32CP92B2VB*81 32CP92B2VC*81 32DP92B2VA*81 32DP92B2VB*81 32DP92B2VD*81 32DP92B2VE*81 32EP92B2VF*81 32EP92B2VG*81 32FP92B2VH*81 32FP92B2VJ*81 32GP92B2VK*81 32GP92B2VL*81 32HP92B2VM*81 32HP92B2VN*81 32IP92B2VP*81 32JP92B2VR*81 4255.00 4255.00 4255.00 4370.00 4370.00 4370.00 4370.00 5089.00 5089.00 6313.00 6313.00 7184.00 7184.00 9203.00 9203.00 18536.00 19675.00 2826.00 2826.00 2826.00 2928.00 2928.00 2928.00 2928.00 3584.00 3584.00 4531.00 4531.00 5324.00 5324.00 6522.00 6522.00 15145.00 16178.00 2542.00 2542.00 2542.00 2645.00 2645.00 2645.00 2645.00 3300.00 3300.00 4083.00 4083.00 4875.00 4875.00 5540.00 5540.00 12406.00 13439.00 32CP92W2VA*81 32CP92W2VB*81 32CP92W2VC*81 32DP92W2VA*81 32DP92W2VB*81 32DP92W2VD*81 32DP92W2VE*81 32EP92W2VF*81 32EP92W2VG*81 32FP92W2VH*81 32FP92W2VJ*81 32GP92W2VK*81 32GP92W2VL*81 32HP92W2VM*81 32HP92W2VN*81 32IP92W2VP*81 32JP92W2VR*81 3868.00 3868.00 3868.00 3972.00 3972.00 3972.00 3972.00 4626.00 4626.00 5738.00 5738.00 6531.00 6531.00 8365.00 8365.00 16850.00 17886.00 32CP92F2VA*81 32CP92F2VB*81 32CP92F2VC*81 32DP92F2VA*81 32DP92F2VB*81 32DP92F2VD*81 32DP92F2VE*81 32EP92F2VF*81 32EP92F2VG*81 32FP92F2VH*81 32FP92F2VJ*81 32GP92F2VK*81 32GP92F2VL*81 32HP92F2VM*81 32HP92F2VN*81 32IP92F2VP*81 32JP92F2VR*81 32CP92N2VA*81 32CP92N2VB*81 32CP92N2VC*81 32DP92N2VA*81 32DP92N2VB*81 32DP92N2VD*81 32DP92N2VE*81 32EP92N2VF*81 32EP92N2VG*81 32FP92N2VH*81 32FP92N2VJ*81 32GP92N2VK*81 32GP92N2VL*81 32HP92N2VM*81 32HP92N2VN*81 32IP92N2VP*81 32JP92N2VR*81 Two Separate Windings, 3-Phase (Constant or Variable Torque) Max Hp NEMA & General Purpose Control NEMA 1 Enclosure 200 230 460 575 NEMA Half Motor Circuit Volts Volts Volts Volts Size Size Interrupter ETI Amps 1 ⁄2 1 3 1 ⁄2 1 3 7 1⁄2 — 10 — 10 10 15 — 25 30 40 1 ⁄2 1 1 1 3 3 3 5 5 1 ⁄2 1 1 1 3 3 7 1⁄2 3 7 1⁄2 7 1⁄2 10 10 — 15 15 10 — — — 20 20 15 25 25 15 30 30 20 — — — 30 30 30 50 50 40 75 75 50 100 100 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 21⁄2 — — 31⁄2 — 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 125 150 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-42 NEMA 1 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ CatalogNumber List Price $ 32CP92B1VA*81 32CP92B1VB*81 32CP92B1VC*81 32DP92B1VA*81 32DP92B1VB*81 32DP92B1VD*81 32DP92B1VE*81 32EP92B1VF*81 32EP92B1VG*81 32FP92B1VH*81 32FP92B1VJ*81 32GP92B1VK*81 32GP92B1VL*81 32HP92B1VM*81 32HP92B1VN*81 32IP92B1VP*81 32JP92B1VR*81 3838.00 3838.00 3838.00 3971.00 3971.00 3971.00 3971.00 4549.00 4549.00 5554.00 5554.00 6293.00 6293.00 8178.00 8178.00 15466.00 16224.00 2446.00 2446.00 2446.00 2567.00 2567.00 2567.00 2567.00 3093.00 3093.00 3842.00 3842.00 4514.00 4514.00 5591.00 5591.00 12354.00 13043.00 2163.00 2163.00 2163.00 2284.00 2284.00 2284.00 2284.00 2809.00 2809.00 3394.00 3394.00 4066.00 4066.00 4610.00 4610.00 9615.00 10304.00 32CP92W1VA*81 32CP92W1VB*81 32CP92W1VC*81 32DP92W1VA*81 32DP92W1VB*81 32DP92W1VD*81 32DP92W1VE*81 32EP92W1VF*81 32EP92W1VG*81 32FP92W1VH*81 32FP92W1VJ*81 32GP92W1VK*81 32GP92W1VL*81 32HP92W1VM*81 32HP92W1VN*81 32IP92W1VP*81 32JP92W1VR*81 3489.00 3489.00 3489.00 3610.00 3610.00 3610.00 3610.00 4135.00 4135.00 5048.00 5048.00 5719.00 5719.00 7435.00 7435.00 14060.00 14748.00 32CP92F1VA*81 32CP92F1VB*81 32CP92F1VC*81 32DP92F1VA*81 32DP92F1VB*81 32DP92F1VD*81 32DP92F1VE*81 32EP92F1VF*81 32EP92F1VG*81 32FP92F1VH*81 32FP92F1VJ*81 32GP92F1VK*81 32GP92F1VL*81 32HP92F1VM*81 32HP92F1VN*81 32IP92F1VP*81 32JP92F1VR*81 32CP92N1VA*81 32CP92N1VB*81 32CP92N1VC*81 32DP92N1VA*81 32DP92N1VB*81 32DP92N1VD*81 32DP92N1VE*81 32EP92N1VF*81 32EP92N1VG*81 32FP92N1VH*81 32FP92N1VJ*81 32GP92N1VK*81 32GP92N1VL*81 32HP92N1VM*81 32HP92N1VN*81 32IP92N1VP*81 32JP92N1VR*81 Dual voltage coils not available in modified starters. conduit hubs and conversion instructions, see page 16-87. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Combination Two Speed Heavy Duty Starters MCP, Constant Horsepower w/ Ambient Compensated Bimetal Overload, Class 32 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 16-148. (6 Required) Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-124. Wiring Diagrams see page 16-134. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. One Winding Consequent Pole, 3-Phase (Constant Horsepower) Max Hp Enclosure 200 230 460 575 NEMA Half Volts Volts Volts Volts Size Size 1 1 1 3 — 1 3 7 1⁄2 — 10 — 15 20 30 30 40 50 75 1 3 — 1 3 7 1⁄2 — 10 — 20 — 30 40 — 50 75 0 0 0 1 1 1 1 — — 2 2 — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 — — 31⁄2 — 3 10 25 3 10 25 30 40 50 40 50 50 50 100 125 150 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 32CP92B2HA*81 32CP92B2HB*81 32CP92B2HC*81 32DP92B2HA*81 32DP92B2HB*81 32DP92B2HD*81 32DP92B2HE*81 32EP92B2HF*81 32EP92B2HG*81 32FP92B2HH*81 32FP92B2HJ*81 32GP92B2HK*81 32HP92B2HM*81 32HP92B2HN*81 32IP92B2HP*81 32JP92B2HR*81 4255.00 4255.00 4255.00 4370.00 4370.00 4370.00 4370.00 5089.00 5089.00 6313.00 6313.00 7184.00 9203.00 9203.00 18536.00 19675.00 2826.00 2826.00 2826.00 2928.00 2928.00 2928.00 2928.00 3584.00 3584.00 4531.00 4531.00 5324.00 6522.00 6522.00 15145.00 16178.00 2542.00 2542.00 2542.00 2645.00 2645.00 2645.00 2645.00 3300.00 3300.00 4083.00 4083.00 4875.00 5540.00 5540.00 12406.00 13439.00 32CP92W2HA*81 32CP92W2HB*81 32CP92W2HC*81 32DP92W2HA*81 32DP92W2HB*81 32DP92W2HD*81 32DP92W2HE*81 32EP92W2HF*81 32EP92W2HG*81 32FP92W2HH*81 32FP92W2HJ*81 32GP92W2HK*81 32HP92W2HM*81 32HP92W2HN*81 32IP92W2HP*81 32JP92W2HR*81 3868.00 3868.00 3868.00 3972.00 3972.00 3972.00 3972.00 4626.00 4626.00 5738.00 5738.00 6531.00 8365.00 8365.00 16850.00 17886.00 32CP92F2HA*81 32CP92F2HB*81 32CP92F2HC*81 32DP92F2HA*81 32DP92F2HB*81 32DP92F2HD*81 32DP92F2HE*81 32EP92F2HF*81 32EP92F2HG*81 32FP92F2HH*81 32FP92F2HJ*81 32GP92F2HK*81 32HP92F2HM*81 32HP92F2HN*81 32IP92F2HP*81 32JP92F2HR*81 32CP92N2HA*81 32CP92N2HB*81 32CP92N2HC*81 32DP92N2HA*81 32DP92N2HB*81 32DP92N2HD*81 32DP92N2HE*81 32EP92N2HF*81 32EP92N2HG*81 32FP92N2HH*81 32FP92N2HJ*81 32GP92N2HK*81 32HP92N2HM*81 32HP92N2HN*81 32IP92N2HP*81 32JP92N2HR*81 CONTROL PRODUCTS ⁄2 1 1⁄2 2 1 ⁄2 1 1⁄2 3 5 — 7 1⁄2 7 1⁄2 10 — 15 25 30 40 NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose 16 ⁄2 1 1⁄2 2 1 ⁄2 1 1⁄2 3 5 — 7 1⁄2 — 7 1⁄2 — 10 20 25 30 Motor Circuit Interrupter ETI Amps NEMA 1 Two Separate Windings, 3-Phase (Constant Horsepower) Max Hp Enclosure 1 ⁄2 1 1⁄2 2 1 ⁄2 1 1⁄2 3 5 — 7 1⁄2 — 7 1⁄2 — 10 20 25 30 1 ⁄2 1 1⁄2 2 1 ⁄2 1 1⁄2 3 5 — 7 1⁄2 7 1⁄2 10 — 15 25 30 40 460 575 NEMA Half Volts Volts Size Size 1 3 — 1 3 7 1⁄2 — 10 — 15 20 30 30 40 50 75 1 3 — 1 3 7 1⁄2 — 10 — 20 — 30 40 — 50 75 0 0 0 1 1 1 1 — — 2 2 — 3 3 — 4 — — — — — — — 13⁄4 13⁄4 — — 21⁄2 — — 31⁄2 — Motor Circuit Interrupter ETI Amps 3 10 25 3 10 25 30 40 50 40 50 50 50 100 125 150 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA NEMA 4/4X Stainless��� NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant NEMA 12, NEMA 3/3R��� NEMA 4 Painted Industrial Use Weatherproof Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 32CP92B1HA*81 2163.00 32CP92B1HB*81 2163.00 32CP92B1HC*81 2163.00 32DP92B1HA*81 2284.00 32DP92B1HB*81 2284.00 32DP92B1HD*81 2284.00 32DP92B1HE*81 2284.00 32EP92B1HF*81 2809.00 32EP92B1HG*81 2809.00 32FP92B1HH*81 3394.00 32FP92B1HJ*81 3394.00 32GP92B1HK*81 4066.00 32HP92B1HM*81 4610.00 32HP92B1HN*81 4610.00 32IP92B1HP*81 9615.00 32JP92B1HR*81 10304.00 3838.00 3838.00 3838.00 3971.00 3971.00 3971.00 3971.00 4549.00 4549.00 5554.00 5554.00 6293.00 7955.00 7955.00 15466.00 16224.00 2446.00 2446.00 2446.00 2567.00 2567.00 2567.00 2567.00 3093.00 3093.00 3842.00 3842.00 4514.00 5591.00 5591.00 12354.00 13043.00 32CP92W1HA*81 3489.00 32CP92W1HB*81 3489.00 32CP92W1HC*81 3489.00 32DP92W1HA*81 3610.00 32DP92W1HB*81 3610.00 32DP92W1HD*81 3610.00 32DP92W1HE*81 3610.00 32EP92W1HF*81 4135.00 32EP92W1HG*81 4135.00 32FP92W1HH*81 5048.00 32FP92W1HJ*81 5048.00 32GP92W1HK*81 5719.00 32HP92W1HM*81 7435.00 32HP92W1HN*81 7435.00 32IP92W1HP*81 14060.00 32JP92W1HR*81 14748.00 32CP92F1HA*81 32CP92F1HB*81 32CP92F1HC*81 32DP92F1HA*81 32DP92F1HB*81 32DP92F1HD*81 32DP92F1HE*81 32EP92F1HF*81 32EP92F1HG*81 32FP92F1HH*81 32FP92F1HJ*81 32GP92F1HK*81 32HP92F1HM*81 32HP92F1HN*81 32IP92F1HP*81 32JP9F1HR*81 32CP92N1HA*81 32CP92N1HB*81 32CP92N1HC*81 32DP92N1HA*81 32DP92N1HB*81 32DP92N1HD*81 32DP92N1HE*81 32EP92N1HF*81 32EP92N1HG*81 32FP92N1HH*81 32FP92N1HJ*81 32GP92N1HK*81 32HP92N1HM*81 32HP92N1HN*81 32IP92N1HP*81 32JP92N1HR*81 Dual voltage coils not available in modified starters. conduit hubs and conversion instructions, see page 16-87. For Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-43 NEMA & General Purpose Control 200 230 Volts Volts NEMA 1 Heavy Duty Contractors 3-Phase, Class 40 Selection Ordering Information Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-106 open and 16-115 enclosed. Wiring Diagrams see page 16-140. Replacement Parts see page 16-155. 䊳 䊳 䊳 䊳 䊳 䊳 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure Open Type NEMA 1 NEMA 4/4X Stainless CONTROL PRODUCTS 16 General Purpose Catalog Number 1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 75 150 — — 40BP32A* 40CP32A* 40DP32A* 40EP32A* 40FP32A* 40GP32A* 40HP32A* 40IP32A* 40JG32A* 40LP32A* 40MP32A* 40NH32A* 40PH32A* 2 5 10 15 25 30 50 75 100 200 400 600 900 2 5 10 15 25 30 50 75 100 200 400 600 900 9 18 27 40 45 60 90 115 135 270 540 810 1215 00 0 1 — 2 — 3 — 4 5 6 7 8 — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — NEMA 12 NEMA 3/3R NEMA 7 & 9 NEMA 3 & 4 Watertight, Dust-tight Watertight, Dust-tight Div1 and Div 2 Industrial Use Corrosion Resistant Corrosion Resistant Class I Groups C & D Weatherproof 304 Stainless Steel Class II Groups E,F&G Class III Bolted Enclosures Indoor/Outdoor Use Contactor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size 1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 100 200 300 450 NEMA 4X Fiberglass List Catalog Price $ Number 198.00 249.00 293.00 422.00 534.00 698.00 861.00 1723.00 2067.00 4506.00 12044.00 17042.00 27103.00 List Price $ 40BP32B* 40CP32B* 40DP32B* 40EP32B* 40FP32B* 40GP32B* 40HP32B* 40IP32B* 40JG32B* 40LP32B* 40MP32B* 40NH32B* 40PH32B* 216.00 268.00 310.00 440.00 621.00 827.00 1033.00 2084.00 2430.00 5168.00 15223.00 20487.00 31893.00 Catalog Number Use Size 0 40CP32W* 40DP32W* 40EP32W* 40FP32W* 40GP32W* 40HP32W* 40IP32W* 40JG32W* 40LP32E* 40MP32E* 40NH32E* 40PH32E* List Catalog Price $ Number — 578.00 621.00 750.00 1240.00 1577.00 1912.00 3584.00 3928.00 7064.00 19530.00 24794.00 35929.00 Use Size 0 40CP32F* 40DP32F* 40EP32F* 40FP32F* 40GP32F* 40HP32F* 40IP32F* 40JG32F* — — — — List Catalog Price $ Number List Catalog Price $ Number — 635.00 684.00 824.00 1364.00 1735.00 2103.00 3943.00 4322.00 — — — — — 1137.00 1189.00 1319.00 1912.00 2377.00 2860.00 4282.00 4626.00 9597.00 — — — Use Size 0 40CP32H* 40DP32H* 40EP32H* 40FP32H* 40GP32H* 40HP32H* 40IP32H* 40JG32H* 40LP32H* — — — List Price $ Use Size 0 40CP320* 40DP320* 40EP320* 40FP320* 40GP320* 40HP320* 40IP320* 40JG320* 40LP320* 40MP320* 40NH320* 40PH320* — 371.00 414.00 414.00 810.00 1033.00 1258.00 2826.00 3170.00 7064.00 17549.00 22812.00 27103.00 Extra Wide Enclosure, 3-Phase, 3-Pole NEMA & General Purpose Control Max Hp Enclosure 200 Volts 230 Volts 1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 460 Volts 575 Volts 2 5 10 15 25 30 50 75 100 2 5 10 15 25 30 50 75 100 Contactor Amp NEMA Half Range Size Size 9 18 27 40 45 60 90 115 135 00 0 1 — 2 — 3 — 4 — — — 1 3/4 — 2 1/2 — 3 1/2 — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Dual voltage coils not available in size 5-8 starters. For conduit hubs and conversion instructions, see page 16-87. NEMA 1 NEMA 4/4X Stainless General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Catalog Number 40BP82B* 40CP82B* 40DP82B* 40EP82B* 40FP82B* 40GP82B* 40HP82B* 40IP82B* 40JG82B* List Price $ 467.00 528.00 570.00 700.00 846.00 1035.00 1352.00 2284.00 2628.00 Enclosure is NEMA Only available Catalog Number Use Size 0 40CP82W* 40DP82W* 40EP82W* 40FP82W* 40GP82W* 40HP82W* 40IP82W* 40JG82W* NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3R Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Industrial Use Weatherproof List Price $ Catalog Number — 982.00 1025.00 1154.00 1912.00 2101.00 3782.00 4712.00 5057.00 Type 4 (painted steel). F coil 100-250V AC 50/60Hz, or DC H coil 150-500V AC 50/60Hz, or DC Only available F coil100-250V AC 50/60Hz, or DC Use Size 0 40CP82H* 40DP82H* 40EP82H* 40FP82H* 40GP82H* 40HP82H* 40IP82H* 40JG82H* Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog — 1929.00 1973.00 2101.00 2695.00 3160.00 3420.00 4840.00 5185.00 Use Size 0 40CP820* 40DP820* 40EP820* 40FP820* 40GP820* 40HP820* 40IP820* 40JG820* — 586.00 629.00 758.00 1215.00 1404.00 2317.00 3248.00 3592.00 Standard Auxiliary Contacts Type All FVNR Starters & Contactors Lugs 16-44 List Price $ Catalog Number List Price $ Size (3rd Character) Configuration B Thru E 1N.O. Internal / External Internal F Thru J 1N.O. External L Thru M 2N.O., 2N.C. External N Thru P 1N.O., 1N.C. External are not included, refer to page 16-86. Discount Schedule NEMA Heavy Duty Contactors Single Phase, 4-Pole & Vacuum, Class 40 Selection Ordering Information Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-106 open and 16-115 enclosed. Wiring Diagrams see page 16-140. Replacement Parts see page 16-155. 䊳 䊳 䊳 䊳 䊳 䊳 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Open Type & Standard Width Enclosure, Single Phase, 2-Pole Max Hp Enclosure Open Type NEMA 1 General Purposes 208/ 115 230 Volts Volts 1 NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3R Watertight, Dust-tight Corrosion Resistant Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosure Indoor/Outdoor Use Industrial Use Weatherproof Contactor Amp NEMA Rating Size Half Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No 9 18 27 35 45 60 90 115 135 — — — — — 21⁄2 — 31⁄2 — 40BP12A* 40CP12A* 40DP12A* 40EP12A* 40FP12A* 40GP12A* 40HP12A* 40IP12A* 40JG12A* 00 0 1 1P 2 — 3 — 4 172.00 224.00 268.00 344.00 500.00 647.00 793.00 1568.00 1912.00 40BP12B* 40CP12B* 40DP12B* 40EP12B* 40FP12B* 40GP12B* 40HP12B* 40IP12B* 40JG12B* 189.00 242.00 285.00 362.00 586.00 775.00 965.00 1930.00 2274.00 Use Size 0 40CP12W* 40DP12W* 40EP12W* 40EP12W* 40GP12W* 40HP12W* 40IP12W* 40JG12W* — 551.00 595.00 1206.00 1206.00 1526.00 1844.00 3428.00 3773.00 List Price $ Catalog No — 607.00 655.00 1327.00 1327.00 1679.00 2029.00 3772.00 4151.00 Use Size 0 40CP12H* 40DP12H* 40EP12H* 40FP12H* 40GP12H* 40HP12H* 40IP12H* 40JG12H* Use Size 0 40CP12F* 40DP12F* 40EP12F* 40EP12F* 40GP12F* 40HP12F* 40IP12F* 40JG12F* List Price $ Catalog No List Price $ — 1112.00 1163.00 1240.00 1877.00 2163.00 2791.00 4126.00 4471.00 Use Size 0 40CP120* 40DP120* 40EP120* 40FP120* 40GP120* 40HP120* 40IP120* 40JG120* — 344.00 388.00 465.00 775.00 982.00 1189.00 2670.00 3015.00 Open Type & Standard Width Enclosure, 4-Pole Max Hp Enclosure Open Type NEMA 1 General Purpose NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3R Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Watertight, Dust-tight Corrosion Resistant Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosure Indoor/Outdoor Use Industrial Use Weatherproof 1 ⁄3 2 3 5 1 1⁄2 3 7 1⁄2 10 2 5 10 15 2 5 10 15 9 18 27 40 00 0 1 — — — — 13⁄4 40BP22A* 40CP22A* 40DP22A* 40EP22A* 224.00 319.00 362.00 491.00 40BP22B* 40BP22B* 40DP22B* 40EP22B* 242.00 242.00 379.00 509.00 Use Size 0 40CP22W* 40DP22W* 40EP22W* — 647.00 689.00 819.00 Use Size 0 40CP22F* 40DP22F* 40EP22F* — 711.00 758.00 901.00 Use Size 0 40CP22H* 40DP22H* 40EP22H* — 1206.00 1258.00 1387.00 Use Size 0 40CP220* 40DP220* 40EP220* — 440.00 482.00 612.00 Vacuum Contactors, 3-Phase, 3-Pole Max Hp 200V 230V 460V 575V 40 75 150 50 100 200 100 200 400 100 200 400 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Dual voltage coils not available for vacuum contactors. Refer to Page 16-94 for a complete list of available coil voltages. Discount Schedule NEMA For Contactor Amp Rating 135 270 540 conduit hubs and conversion instructions, see page 16-87. To order single phase contactor in an extra wide enclosure, order the enclosure kit from Page 16-90 and the open style contactor as separate items. Open Type NEMA Size Catalog Number 4 5 6 40JV32A* 40LV32A* 40MV32A* List Price $ 2397.00 4842.00 13539.00 Coils D, F, or G will be wired for incoming voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. 1 NO Auxiliary. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-45 NEMA & General Purpose Control Contactor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ CONTROL PRODUCTS 1 2 3 5 7 1⁄2 10 15 — — NEMA 4X Fiberglass 16 ⁄3 1 2 3 3 5 7 1⁄3 — — NEMA 4/4X Stainless Reversing Heavy Duty Contactors Class 43 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see pages 16-107 open and 16-120 enclosed. Wiring Diagrams see page 16-140. Replacement Parts see page 16-155. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 16-94. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure Open Type NEMA 1 General Purpose Contactor 200 230 460 575 Amp NEMA Half Catalog Volts Volts Volts Volts Rating Size Size Number CONTROL PRODUCTS 16 1 ⁄2 3 7 1⁄2 10 10 15 25 30 40 75 100 — — 1 ⁄2 3 7 1⁄2 10 15 20 30 40 50 100 200 300 450 2 5 10 15 25 30 50 75 100 200 400 600 900 2 5 10 15 25 30 50 75 100 200 400 600 900 9 18 27 40 45 60 90 115 135 270 540 810 1215 00 0 1 — 2 — 3 — 4 5 6 7 8 — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — 43BP32A* 43CP32A* 43DP32A* 43EP32A* 43FP32A* 43GP32A* 43HP32A* 43IP32A* 43JG32A* 43LP32A* 43MP32A* 43NH32A* 43PH32A* List Catalog Price $ Number 517.00 621.00 707.00 965.00 1344.00 1784.00 2231.00 4875.00 5566.00 11113.00 26172.00 37088.00 72272.00 NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight NEMA 3 & 4 Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel List Catalog Price $ Number List Price $ Corrosion Resistant Catalog Number 43BP32B* 551.00 Use Size 0 — Use Size 0 43CP32B* 655.00 43CP32W* 1051.00 43CP32F* 43DP32B* 758.00 43DP32W* 1309.00 43DP32F* 43EP32B* 1016.00 43EP32W* 1568.00 43EP32F* 43FP32B* 1482.00 43FP32W* 2377.00 43FP32F* 43GP32B* 1973.00 43GP32W* 3084.00 43GP32F* 43HP32B* 2473.00 43HP32W* 3799.00 43HP32F* 43IP32B* 5324.00 43IP32W* 7668.00 43IP32F* 43JG32B* 6013.00 43JG32W* 8357.00 43JG32F* 43LP32B* 13707.00 43LP32E* 16739.00 — 43MP32B* 30480.00 43MP32E* 34788.00 — 43NH32B* 41395.00 43NH32E* 45703.00 — — — — — — NEMA 12 NEMA 3/3R Div 1 and Div 2 Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use List Catalog Price $ Number List Price $ Catalog Number List Price $ — 1156.00 1442.00 1725.00 2616.00 3393.00 4179.00 8435.00 9193.00 — — — — — 2137.00 2360.00 2620.00 3938.00 5023.00 6323.00 11491.00 12182.00 — — — — Use Size 0 43CP320* 43DP320* 43EP320* 43FP320* 43GP320* 43HP320* 43IP320* 43JG320* 43LP320* 43MP320* 43NH320* — — 810.00 914.00 1172.00 1740.00 2387.00 3042.00 6203.00 6892.00 15534.00 32124.00 43721.00 — Use Size 0 43CP32H* 43DP32H* 43EP32H* 43FP32H* 43GP32H* 43HP32H* 43IP32H* 43JG32H* — — — — Open Type & Standard Width Enclosure, Single Phase, 3-Wire, 2-Pole Max Hp Enclosure NEMA & General Purpose Control Open Type Cont208/ actor 115 230 Amp NEMA Volts Volts Rating Size Catalog No 1 1⁄3 1 2 3 1 2 3 5 9 18 27 35 00 0 1 1P 43BP12A* 43CP12A* 43DP12A* 43EP12A* NEMA 1 NEMA 4/4X Stainless NEMA 4X Fiberglass General Purpose Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel List Price $ Catalog No List Price $ Catalog No 500.00 603.00 689.00 947.00 43BP12B* 43CP12B* 43DP12B* 43EP12B* Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Dual voltage coils not available in size 5–8 starters. For conduit hubs and conversion instructions, see page 16-87. 16-46 534.00 637.00 741.00 1000.00 Use Size 0 43CP12W* 43DP12W* 43EP12W* List Price $ — 1033.00 1293.00 1551.00 Watertight, Dust-tight Corrosion Resistant NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3R Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Industrial Use Weatherproof Catalog No List Price $ Catalog No List Price $ Use Size 0 43CP12F* 43DP12F* 43EP12F* — 1137.00 1423.00 1706.00 Use Size 0 43CP12H* 43DP12H* 43EP12H* — 2231.00 2343.00 2602.00 Enclosure Coils D, F, is NEMA Type 4 (painted steel). or G will be wired for incoming voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. Only available F coil 100-250V AC 50/60Hz, or DC H coil 150-500V AC 50/60Hz, or DC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog No Use Size 0 43CP120* 43DP120* 43EP120* List Price $ — 793.00 896.00 1154.00 Only available F coil 100-250V AC 50/60Hz, or DC contacts 43B-43E 4th pole built-in 43F-43J 2 NO & 2 NC Auxiliary Discount Schedule NEMA Overload Relays Solid State ESP100 & 3RB20, Special Use 958, Oil Field 958L, and Thermal Features Application ESP100 Solid State Overloads ESP100 solid state overload relays are self powered, requiring no separate 120V source to power the circuit board. They provide phase loss protection, fewer connection points and high repeat trip accuracy which results in longer motor life and cost savings. NEMA Class 10, 20 and 30 trip curves are available for a variety of applications. The ESP100 solid state overload provides phase loss protection for the motor by tripping within three seconds upon complete loss of one phase of a three phase motor branch circuit. 958 overload dials denote must hold amps. Must trip amps are 112% of the must hold setting. 958L ESP100 Oil Field Solid State Overload Relays 958L ESP100 solid state overloads are designed specifically for the oil market and the cyclical loads experienced with these types of pumping applications. These overloads provide protection on all standard motors, oil well pump motors, multi-torque connections, and ultra-high slip motors. Each overload has at least a 2:1 current adjustment range with the adjustment dial reading out in full load amps. In addition to the markings on the dial there are audible clicks which allow for extremely fine tuning. The heaterless construction of these overloads minimizes energy costs and the costs of cabinet ventilation or cooling. Solid state overloads can be used at temperatures from – 30°C to ѿ70°C and are rated for 50Hz and 60Hz applications. ESP100 panel mounted overloads can be used to upgrade existing starter applications where panel mounted thermal overloads are used. In addition, ESP100 overloads can be panel mounted when used with other types of controllers, such as DP, IEC contactors, and soft starts. ESP100 overloads can be used on high voltage applications, making them ideal for use with vacuum contactors and other high voltage control. ESP100 overloads can be retrofitted on existing contactors using the retrofit plate suffixes or on other brands using the plates listed in the competitive retrofit plates table on page 16-48. 958 ESP100 Special Use Solid State Overloads 958 ESP100 special use solid state overloads provide excellent protection of hermetically sealed compressors and Figure 1 27 24 13 22 20 ESP100 Solid State Overload 958 or 958L Solid State Overload 15 18 TYPICAL SOLID-STATE OVERLOAD ADJUSTMENT DIAL MARKINGS Ambient Compensated Bimetal—Single Phase and Three Phase Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-47 NEMA & General Purpose Control Ambient Compensated Bimetal Overloads These thermal type overload relays are used to protect motors from excessive heat resulting from sustained motor overloads, rapid motor cycling and stalled rotor conditions. Although these devices function based on thermal principles they are designed to compensate for the ambient air temperature surrounding the overload. This helps prevent the occurrence of nuisance tripping when there are high surrounding ambient temperatures. The percentage of overload determines the length of time required to open the circuit. CONTROL PRODUCTS Rotors can be damaged in 8 to 15 seconds during motor stall conditions if electrical power is not removed. To prevent damage during motor stall, the 958L solid-state overload removes power in 7 seconds at 250% locked rotor current. Therefore, die cast or fabricated rotors will be protected from damage saving the user both time and money. 16 ▪ Solid State ESP100, 958 & 958L Overloads —Phase Loss Protection —Trips Within 3 Seconds —Ambient Insensitive —Heaterless Design —Self-Powered —앐 2% Repeat Trip Accuracy —NEMA Class 10, 20 & 30 Trip Curves Available —FLA Adjustment Dial with Wide Adjustment Range (Fig. 1) —Short Circuit Self Protected —Thermal Memory Circuit —Conformally Coated Circuit Board — – 22°F to 159°F (– 30°C to 70°C) —NC Contact Rated NEMA A600, P600 (10 Amps 600VAC Max., 5 Amps 600VDC Max.) —“Must Hold Amps” Adjustment Dial (958 only) Ambient Compensated Bimetal ▪ Overloads —Automatic or manual reset adjustment —A manual test button is provided to test the operation of the 3-pole overload relay control contacts —앐15% nominal trip current adjustment —Accept either standard Class 20 or Quick Trip (NEMA Class 10) heater elements without any other changes or adjustments —Available with a normally open contact for an alarm circuit (SPDT) up to 60A —Compensated bimetal overload relays provide a constant trip time in ambient temperatures from –20°F to ѿ170°F for a given heater rating ▪ UL Listed File #E22655 or Component Recognized ▪ CSA Certified File #LR6535 ▪ 3RB20 Solid State Overload Relay —Marking Strip —STOP button —1 NO and 1 NC contacts —Trip class 10 or 20 —Test function and switch position indicator —4:1 current adjustment dial e.g. 160630A —Phase loss protection —Self-powered General artificially cooled motors which require ambient insensitivity and quick trip response times. Combined with a series lockout relay, they can provide unsurpassed protection for hermetically sealed compressor motors in air conditioning applications. The combination of high trip speed, current adjustment, and ease of installation makes it suitable for these applications. The trip curves have been custom tailored to provide proper overload protection on such loads without causing nuisance tripping. Overload Relays Solid State and Thermal, Class 48, ESP100 and 3RB20 Selection Ordering Information 䊳 䊳 3RB20 Solid State Overload Relay ESP100 Solid State Overload Relay 䊳 䊳 Ambient Compensated Bimetal 3-Phase Overload Relay For Thermal Overloads, order heater elements by code number at $13.00 each. Field Modification Kits see page 16-79. Dimensions see page 16-108. To retrofit existing Thermal Furnas Brand Starters with the ESP100 Solid State Overload Relay add the appropriate suffix to the end of the catalog number from the Retrofit Plates table shown below and also add $14.30 to the list price. Example: 48ASE3M201P. Or order the Plate Kit Separate 49ASMP1, 2, or 3. CONTROL PRODUCTS 16 Solid State—Class 48 ESP100, 3-Phase, Single Phase (Panel Mount and Replacement) Full Load Amp Current Range 0.25–1 0.75–3 2.5–10 9–18 13–27 20–40 13–27 22–45 30–60 45–90 57–115 67–135 81–162 100–210 100–270 200–540 250–750 420–820 420–1220 0.25-1 0.75-3 2.5-10 5-16 Phase Frame Size Manual Reset Class 10 Catalog Number List Price $ Manual Reset Class 20 Catalog Number List Price $ Manual Reset Class 30 Catalog Number List Price $ 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 A A A A1 A1 A1 B B B B B B B A A A A A A A A A A 48ASA3M10 48ASB3M10 48ASD3M10 48ASE3M10 48ASF3M10 48ASG3M10 48BSF3M10 48BSH3M10 48BSJ3M10 48BSK3M10 48BSL3M10 48BSM3M10 48BSN3M10 48ASS3M10 48ASU3M10 48ASX3M10 48CSH3M10 48CSY3M10 48CSZ3M10 48ASA1M10 48ASB1M10 48ASD1M10 48ASE1M10 117.00 117.00 117.00 117.00 117.00 151.00 163.00 163.00 198.00 198.00 289.00 289.00 289.00 143.00 143.00 143.00 143.00 143.00 143.00 107.00 107.00 107.00 107.00 48ASA3M20 48ASB3M20 48ASD3M20 48ASE3M20 48ASF3M20 48ASG3M20 48BSF3M20 48BSH3M20 48BSJ3M20 48BSK3M20 48BSL3M20 48BSM3M20 48BSN3M20 48ASS3M20 48ASU3M20 48ASX3M20 48CSH3M20 48CSY3M20 48CSZ3M20 48ASA1M20 48ASB1M20 48ASD1M20 48ASE1M20 117.00 117.00 117.00 117.00 117.00 151.00 163.00 163.00 198.00 198.00 289.00 289.00 289.00 143.00 143.00 143.00 143.00 143.00 143.00 107.00 107.00 107.00 107.00 48ASA3M30 48ASB3M30 48ASD3M30 48ASE3M30 48ASF3M30 48ASG3M30 48BSF3M30 48BSH3M30 48BSJ3M30 48BSK3M30 48BSL3M30 48BSM3M30 48BSN3M30 48ASS3M30 48ASU3M30 48ASX3M30 48CSH3M30 48CSY3M30 48CSZ3M30 48ASA1M30 48ASB1M30 48ASD1M30 48ASE1M30 117.00 117.00 117.00 117.00 117.00 151.00 163.00 163.00 198.00 198.00 289.00 289.00 289.00 143.00 143.00 143.00 143.00 143.00 143.00 107.00 107.00 107.00 107.00 Solid State—3RB206, 3-Phase For Contactor Size Setting Range Amps Manual/Automatic Reset Class 10 List Catalog Number Price $ 5 6 55-250 160-630 3RB2066-1GC2 3RB2066-1MC2 377.00 540.00 Class 20 Catalog Number List Price $ 3RB2066-2GC2 3RB2066-2MC2 397.00 560.00 NEMA & General Purpose Control Ambient Compensated Bimetal—Open Type Class 48 Single Phase, 3-Phase (Panel Mount Only) Poles 1 3 Amp Rating Auxiliary Contacts 25 60 100 180 30 30 60 60 100 180 1 NC 1 NC 1 NC 1 NC 1 NC 1 NO/NC 1 NC 1 NO/NC 3 NC 3 NC Contact Rating 5A (B600) & 5A (P300) 10A (A600) & 5A (P300) 5A (B600) & 5A (P300) Catalog Number List Price $ 48DA18AA4 48GA18AA4 48HA18AA4 48JA18AA4 48DC38AA4 48DC39AA4 48GC38AA4 48GC39AA4 48HA38AA4 48JA38AA4 38.00 56.00 72.00 117.00 77.00 111.00 111.00 147.00 198.00 285.00 Retrofit Plates for Contactors, Class 48 Replacement for Starter Sizes ESP100 Overload Frame Size Retrofit Plate Suffix Plate Kit Separate Price Adder $ Size 00–13⁄4 Size 2, 21⁄2 Size 3, 31⁄2 Size 4 A or A1 B B B 1P 2P 3P 4P 49ASMP1 49ASMP2 49ASMP3 49ASMP3 14.30 14.30 14.30 14.30 To determine frame size of replacement solid state overload, refer to retrofit plates table above. Temperature rating Ҁ20° to 60°C. Requires use of 300:5 Current Transformers–3 of 97CT005. Requires use of 600:5 Current Transformers–3 of 97CT008. 16-48 Requires use of 1200:5 Current Transformers–3 of 97CT012. Overload has busbar connections. Discount Code: IEC. Requires use of 750:5 Current Transformers–3 of 97CT009. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog See note under Ordering Information to retrofit existing Thermal Starters with ESP100 Solid State Overload Relay. For replacement of Starter Mounted Overload Relay, refer to page 16-157. Discount Schedule NEMA Overload Relays Special Use Solid State Overloads, Class 958 and 958L Selection Ordering Information 䊳 䊳 Standard Class 958 — Manual Reset, Trip Curve A Full Load Amp Current Range Phase For Use On Controller Sizes Catalog Number Rating Catalog No. List Price $ 150:5 97CT002 158.00 200:5 97CT003 158.00 250:5 97CT004 158.00 300:5 97CT005 158.00 400:5 97CT006 158.00 600:5 97CT008 158.00 750:5 97CT009 158.00 1200:5 97CT012 158.00 Oil Field Class 958L —Manual Reset List Price $ 15–30 3 1– 1 3⁄4 958AA32A 323.00 22–44 3 1 3⁄4 958BA32A 323.00 33–66 3 2–3 958CA32A 374.00 50–100 3 3 –3 1⁄2 958DA32A 374.00 75–150 3 4 958EA32A 410.00 90–180 3 4 958FA32A 430.00 Full Load Amp Current Range 5.6–11.6 7–14 11–22 14–28 18–36 20–40 18–36 28–56 35–70 43–86 50–90 60–126 75–150 84–174 105–210 132–264 264–528 Phase 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 For Use On Controller Sizes 3 0–1 ⁄4 0–1 3⁄4 1, 1 3⁄4 1, 1 3⁄4 1 3⁄4 1 3⁄4 2–4 2 1⁄2–4 3–4 3–4 3–4 4 — — — — — Catalog Number 958L109307U 958L109308U 958L109309U 958L109330U 958L109331U 958L109332U 958L109313U 958L109314U 958L109329U 958L109315U 958L109311U 958L109316U 958L109312U 958L109327U 958L109328U 958L109522U 958L109523U List Price $ 158.00 158.00 158.00 158.00 193.00 193.00 206.00 239.00 239.00 239.00 239.00 330.00 186.00 186.00 186.00 186.00 186.00 958L Trip Curve 16 Trip Curve A Current Transformers Field Modification Kits see page 16-79. Dimensions see page 16-108. CONTROL PRODUCTS NEMA & General Purpose Control Temperature rating 앥20° to 쎵60°C. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-49 Current Sensitive Relay Class 97 General Features Electrical Data ▪ Start Up Delay ▪ Trip Delay ▪ Overcurrent or Undercurrent Trip Applications ▪ Manual or Automatic Reset Start-up delay, trip delay and current trip (undercurrent trip on Model 97U and overcurrent trip on the Model 97A) adjustments are provided to match the current sensitive relay to a specific application. Reset can be switch selectable for manual or automatic. Supply Voltage: 100–140VAC, 60Hz (240VAC available) Start Up Time Delay: 1–6 seconds. Begins when motor current is above 10% of current trip point. Output is inhibited if motor current is below 10% of current set point. Trip Time Delay: Model 97U 0.5–2.5 seconds Model 97A 0.2–2.5 seconds Reset: Manual or Automatic switch selectable Description Fault Indicator: LED, ON during fault Contact Rating: 1 SPDT, 2.5 amp @ 250VAC (NEMA C300) Wire Termination: Saddle clamp Wire range: Two #12 to #18 gauge Sensing Loop Wire Size: 6 gauge maximum except 97AAF3010 2/0 gauge maximum Operating Temperature Range: Ҁ25°C to ѿ60°C Set Point Repeatability: 앐2% over temperature range of 0° to ѿ60°C 앐4% over temperature range of Ҁ25° to 0°C Current Transformers (Optional): Refer to page 16-49 for Selection NEMA & General Purpose Control CONTROL PRODUCTS 16 The Class 97 current sensitive relay is a device that monitors motor current and provides an instantaneous output if the motor current is over (Model 97A) or under (Model 97U) an adjustable set point. These over or under current conditions may be the result of a change in system status such as a jam, broken belt or dry well. Control voltage of 120V AC or 240V AC is required to operate the relay. An SPDT, 2.5 amp relay output contact is provided. No current transformers are required below 100 amps (56 amps for undercurrent relay). Class 97 Current Sensitive Relay Operation Model 97A—Overcurrent Sensitive Relay 16-50 Model 97U—Undercurrent Sensitive Relay Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Current Sensitive Relay Class 97 Selection Ordering Information 왘 왘 왘 For Current Transformers refer to page 16-49. Dimensions see pages 16-108. Wiring Diagrams see page 16-143. Undercurrent Reset Type Mounting Control Voltage 120VAC Panel Mount 240VAC Man/ Auto Free Standing 120VAC 240VAC Current Trip Amp Adjustment Range 2–7 4–16 7–28 14–56 2–7 4–16 7–28 14–56 2–7 4–16 7–28 14–56 4–16 7–28 Hp Range @ 460VAC 햲 3–71⁄ 2 5–15 10–30 20–60 3–71⁄ 2 5–15 10–30 20–60 3–71⁄ 2 5–15 10–30 20–60 5–15 10–30 Max Continuous Operation Current Catalog Number 125A 140A 140A 140A 125A 140A 140A 140A 125A 140A 140A 140A 140A 140A 97UMM0207 97UMM0416 97UMM0728 97UMM1456 97UMM0207G 97UMM0416G 97UMM0728G 97UMM1456G 97UMF0207 97UMF0416 97UMF0728 97UMF1456 97UMF0416G 97UMF0728G Catalog Number 97AMM0207 97AMM0416 97AMM0728 97AMM1456 97AMM3010 97AMM0207G 97AMM1456G 97AMM3010G 97AMF0207 97AMF0416 97AMF0728 97AMF1456 97AMF3010 97AMF0207G 97AMF0416G 97AMF0728G 97AMF1456G 97AMF3010G List Price $ 388.00 388.00 388.00 388.00 388.00 388.00 388.00 388.00 352.00 352.00 352.00 352.00 352.00 352.00 Overcurrent 120VAC Panel Mount 240VAC Man/ Auto Free Standing 240VAC 햲 @ 460VAC 햲 Max Continuous Operation Current 2–7 4–16 7–28 14–56 30–100 2–7 14–56 30–100 2–7 4–16 7–28 14–56 30–100 2–7 4–16 7–28 14–56 30–100 3–71⁄ 2 5–15 10–30 20–60 30–75 3–71⁄ 2 20–60 30–75 3–71⁄ 2 5–15 10–30 20–60 30–75 3–71⁄ 2 5–15 10–30 20–60 30–75 125A 140A 140A 140A 140A 125A 140A 140A 125A 140A 140A 140A 140A 125A 140A 140A 140A 140A Hp Range List Price $ 388.00 388.00 388.00 388.00 388.00 388.00 388.00 388.00 352.00 352.00 352.00 352.00 352.00 352.00 352.00 352.00 352.00 352.00 NEMA & General Purpose Control 120VAC Current Trip Amp Adjustment Range CONTROL PRODUCTS Mounting Control Voltage 16 Reset Type T These catalog numbers can also be used on voltage systems other than 460VAC by changing the Hp range proportionally. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-51 Duplex Heavy Duty Controllers General Class 83 Class 84 NEMA & General Purpose Control CONTROL PRODUCTS 16 Features ▪ Heavy Duty NEMA Starters ▪ Solid State or Thermal Overload Relays ▪ Fusible or MCP ▪ Heavy Duty Disconnect Handle ▪ Flexibility with Field Modifications ▪ Alternator Transfer on De-energization ▪ UL Listed for Outdoor Use and Service Equipment File #E14900 Application Duplex pump controls are designed to perform one or both of two distinct functions: duplexing and alternation. The duplexing function provides capacity for system peaking or above normal demand without having the full motor capacity spinning at all times. It also provides standby capacity for use when one of the motors or pumps is disabled. The duplexing function is also referred to as lead/lag or main/standby. When two pumps or compressors are controlled by a duplex controller, they are started in sequence as necessary to attain preset values of pressure, flow or liquid level. Two field devices such as pressure switches or float switches provide electrical signals to the duplex controller. One remote device is set to initiate the 16-52 starting of the lead motor. This motor is rated to handle normal system demand. The second motor is usually the same rating and is referred to as the lag motor. It is only energized when the system demand is greater than the capacity of the lead motor. The lag motor is started when the second remote device is signalling for more output than the lead motor can produce. The alternation function reverses the lead and lag mode for the two motors in a duplex system. Upon alternation the first motor as described above becomes the lag motor and the second motor assumes the lead function. The alternation is usually programmed to occur at any time both pumps come to rest. The alternation function equalizes wear on the two machines and extends the life of seals and bearings. Enclosure Types Duplex controllers are available in NEMA 1, 12/3/3R, 4 (painted) and 4/4X (stainless) enclosures. Enclosures protect personnel from contact with live parts and depending upon the construction, protect the control in varying degrees from physical damage and harmful atmospheres. All enclosures are supplied with corrosion resistant finishes. Heavy Duty Starters These Duplex controllers use the same starters described in the heavy duty starter section of this catalog. ESP 100 solid state overload starters and ambient compensated bimetal overload starters are available. Siemens Type ETI Circuit Breaker The ETI circuit breaker is a device designed specifically for application in motor circuits. The ETI is a magnetic only protective device designed to provide protection against short circuit current. The instantaneous-only type ETI circuit breaker employs adjustable magnetic trip settings to allow broader application ranges and a higher degree of motor short circuit protection. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Features Two control transformers may be provided for low voltage control to safeguard personnel from high voltage. One transformer is required for each starter to provide independent control circuits. A Hand-Off-Auto selector switch for each starter may be mounted in the enclosure door or furnished separately for remote control. Test push buttons or pilot lights may also be installed on the enclosure. Solid-state or Ambient Compensated Bimetal Overload Relays are supplied as standard. New Heavy Duty Disconnect Switches The disconnect switch that goes the distance in durability, performance and reliability has been made even better to give you greater advantages: ▪ Visible blades for the highest level of safety ▪ Double break switching action to reduce arcing, increase lifetime and eliminate the “electric hinge” ▪ More rugged positive action switch ▪ Oversized lugs are standard ▪ Line side shield to help guard personnel from contact with live parts ▪ Higher horsepower rating for design E high efficiency motors ▪ Now UL listed for IIsco, Burndy and T&B crimp type lugs ▪ The 200A switch now accepts up to 300 MCM versus 250 MCM wire size Its rugged construction - with a high fault withstand rating of 100kA at 600 VAC when fused with class R rated fuses - meets the most stringent industry standards set forth by the automotive, petro-chemical, and pulp and paper industries. UL recognized and CSA certified, our disconnect switches are available either non-fusible or fusible with class R and class J fuse clips. Duplex Heavy Duty Controllers Non - Combination, Class 83 Selection Coil Table Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Standard coil voltage supplied will be 120V, separate control. For non-alternator styles (see factory modifications) change the 9th character using the coil table. Heater elements for bimetal overloads see page 16-148 (6-Required). Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-126. Wiring Diagrams see page 16-141. Replacement Parts see pages 16-155. 60Hz Voltage Letter 24 Separate Control 120 Separate Control 200–208 220–240 277 440–480 550–600 J F D G L H E Non-Combination (with Solid-State Overload) Max Hp 200 Volts Enclosure 230 Volts ⁄ 1⁄2 ⁄ 3⁄4 16 16 2 3 2 3 ⁄ ⁄ ⁄ ⁄ 16 16 460 Volts ⁄ 13 1 1⁄2 5 — ⁄ 13 575 Volts ⁄ 12 2 5 — ⁄ 12 34 — — — — — — — — — 1 3⁄4 1 3⁄4 — — 2 1⁄2 2 1⁄2 — — 3 1⁄2 — 0.25-1 0.75-3 2.5-10 9-18 0.25-1 0.75-3 2.5-10 9-18 13-27 13-27 20-40 13-27 22-45 22-45 30-60 30-60 45-90 57-115 67-135 NEMA 4 Painted NEMA 4/4X Stainless Industrial Use Weatherproof Watertight Dust-tight Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Catalog Number List Price $ 83CSA92BF 83CSB92BF 83CSD92BF 83CSE92BF 83DSA92BF 83DSB92BF 83DSD92BF 83DSE92BF 83DSF92BF 83ESF92BF 83ESG92BF 83FSF92BF 83FSH92BF 83GSH92BF 83GSJ92BF 83HSJ92BF 83HSK92BF 83ISL92BF 83JSM92BF 1482.00 1482.00 1482.00 1482.00 1577.00 1577.00 1577.00 1577.00 1577.00 1835.00 1835.00 2335.00 2335.00 2791.00 2791.00 3170.00 3170.00 5704.00 6392.00 Catalog Number 83CSA920F 83CSB920F 83CSD920F 83CSE920F 83DSA920F 83DSB920F 83DSD920F 83DSE920F 83DSF920F 83ESF920F 83ESG920F 83FSF920F 83FSH920F 83GSH920F 83GSJ920F 83HSJ920F 83HSK920F 83ISL920F 83JSM920F List Price $ Catalog Number 1629.00 1629.00 1629.00 1629.00 1723.00 1723.00 1723.00 1723.00 1723.00 1981.00 1981.00 2714.00 2714.00 3282.00 3282.00 3661.00 3661.00 7331.00 8020.00 83CSA92EF 83CSB92EF 83CSD92EF 83CSE92EF 83DSA92EF 83DSB92EF 83DSD92EF 83DSE92EF 83DSF92EF 83ESF92EF 83ESG92EF 83FSF92EF 83FSH92EF 83GSH92EF 83GSJ92EF 83HSJ92EF 83HSK92EF 83ISL92EF 83JSM92EF List Price $ Catalog Number List Price $ 1956.00 1956.00 1956.00 1956.00 2067.00 2067.00 2067.00 2067.00 2067.00 2326.00 2326.00 3360.00 3360.00 4721.00 4721.00 5100.00 5100.00 8994.00 9683.00 83CSA92WF 83CSB92WF 83CSD92WF 83CSE92WF 83DSA92WF 83DSB92WF 83DSD92WF 83DSE92WF 83DSF92WF 83ESF92WF 83ESG92WF 83FSF92WF 83FSH92WF 83GSH92WF 83GSJ92WF 83HSJ92WF 83HSK92WF 83ISL92WF 83JSM92WF 3463.00 3463.00 3463.00 3463.00 3575.00 3575.00 3575.00 3575.00 3575.00 3834.00 3834.00 4868.00 4868.00 6229.00 6229.00 6967.00 6967.00 10860.00 11549.00 CONTROL PRODUCTS 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 0 0 0 0 1 1 1 1 1 — — 2 2 — — 3 3 — 4 NEMA 12/3R General Purpose 16 1 1⁄2 2 2 5 5 3 10 10 7 1⁄2 — — — 15 15 10 — — — 15 20 15 25 25 — 30 30 20 — — — 30 40 30 50 50 40 75 75 50 100 100 12 Overload NEMA Half Amp Size Size Range NEMA 1 Non-Combination (with Ambient Compensated Bimetal Overload) Max Hp Enclosure 230 Volts 460 Volts 3 7 1⁄2 10 10 15 25 30 40 3 5 7 1⁄2 10 10 15 15 25 20 30 30 50 40 75 50 100 575 Volts 5 10 15 25 30 50 75 100 NEMA Half Size Size 0 1 — — — 1 3⁄4 2 — — 2 1⁄2 3 — — 3 1⁄2 4 — NEMA 12/3R NEMA 4 Painted NEMA 4/4X Stainless General Purpose Industrial Use Weatherproof Watertight Dust-tight Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Catalog Number List Price $ Catalog Number 83CP92BF81 83DP92BF81 83EP92BF81 83FP92BF81 83GP92BF81 83HP92BF81 83IP92BF81 83JP92BF81 1405.00 1498.00 1758.00 2256.00 2714.00 3093.00 5626.00 6315.00 83CP920F81 83DP920F81 83EP920F81 83FP920F81 83GP920F81 83HP920F81 83IP920F81 83JP920F81 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA List Price $ List Price $ Catalog Number List Price $ 1877.00 1991.00 2249.00 3282.00 4643.00 5022.00 8917.00 9605.00 83CP92WF81 83DP92WF81 83EP92WF81 83FP92WF81 83GP92WF81 83HP92WF81 83IP920W81 83JP92WF81 3385.00 3498.00 3756.00 4789.00 6151.00 6888.00 10784.00 11472.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-53 1551.00 1645.00 1905.00 2636.00 3205.00 3584.00 7254.00 7943.00 Catalog Number 83CP92EF81 83DP92EF81 83EP92EF81 83FP92EF81 83GP92EF81 83HP92EF81 83IP92EF81 83JP92EF81 NEMA 12 is field convertible to NEMA 3/3R. For conduit hubs and conversion instructions, see page 16-87. available on standard alternator style ('92' in the catalog number). Not NEMA & General Purpose Control 200 Volts NEMA 1 Duplex Heavy Duty Controllers Combination Disconnect (Fusible & Non-Fusible), Class 84 Selection Coil Table Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Standard coil voltage supplied will be 120V, separate control. For non-alternator styles (see factory modifications) change the 10th character using the coil table. Heater elements for bimetal overloads see page 16-148 (6-Required). For factory installed fusible disconnect, see page 16-95. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-126. Wiring Diagrams see page 16-141. Replacement Parts see pages 16-155. 60Hz Voltage Letter 24 Separate Control 120 Separate Control 200–208 220–240 277 440–480 550–600 J F D G L H E Two Disconnect Switches with Solid-State Overload Max Hp 200 Enclosure 230 Volts Volts ⁄ ⁄ 2 3 1⁄6 1⁄2 2 3 7 1⁄2 ⁄ ⁄ 2 3 1⁄6 3⁄4 2 3 7 1⁄2 16 16 CONTROL PRODUCTS 16 12 34 NEMA 1 NEMA 12/3R NEMA 4 Painted NEMA 4X Stainless General Purpose Industrial Use Weatherproof Watertight Dust-tight Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel 460 575 NEMA Half Overload Disc Amp Amp Volts Volts Size Size Range Catalog Rating Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number 0 0 0 0 1 1 1 1 1 — — — — — — — — — 0.25-1 0.75-3 2.5-10 9-18 0.25-1 0.75-3 2.5-10 9-18 13-27 13-27 20-40 13-27 22-45 22-45 30-60 30-60 45-90 57-115 67-135 30 30 30 30 30 30 30 30 30 60 60 60 60 100 100 100 100 200 200 2335.00 2335.00 2335.00 2335.00 2430.00 2430.00 2430.00 2430.00 2430.00 2688.00 2688.00 3489.00 3489.00 5022.00 5022.00 5401.00 5401.00 9166.00 9855.00 84CSA920DF 84CSB920DF 84CSD920DF 84CSE920DF 84DSA920DF 84DSB920DF 84DSD920DF 84DSE920DF 84DSF920DF 84ESF920DF 84ESG920DF 84FSF920DF 84FSH920DF 84GSH920DF 84GSJ920DF 84HSJ920DF 84HSK920DF 84ISL920DF 84JSM920DF 2791.00 2791.00 2791.00 2791.00 2886.00 2886.00 2886.00 2886.00 2886.00 3145.00 3145.00 4135.00 4135.00 5859.00 5859.00 6238.00 6238.00 11483.00 12174.00 84CSA92EDF 84CSB92EDF 84CSD92EDF 84CSE92EDF 84DSA92EDF 84DSB92EDF 84DSD92EDF 84DSE92EDF 84DSF92EDF 84ESF92EDF 84ESG92EDF 84FSF92EDF 84FSH92EDF 84GSH92EDF 84GSJ92EDF 84HSJ92EDF 84HSK92EDF 84ISL92EDF 84JSM92EDF 4152.00 4152.00 4152.00 4152.00 4247.00 4247.00 4247.00 4247.00 4247.00 4506.00 4506.00 6298.00 6298.00 9915.00 9915.00 10294.00 10294.00 15420.00 16109.00 84CSA92WDF 84CSB92WDF 84CSD92WDF 84CSE92WDF 84DSA92WDF 84DSB92WDF 84DSD92WDF 84DSE92WDF 84DSF92WDF 84ESF92WDF 84ESG92WDF 84FSF92WDF 84FSH92WDF 84GSH92WDF 84GSJ92WDF 84HSJ92WDF 84HSK92WDF 84ISL92WDF 84JSM92WDF 1⁄3 1 1⁄2 5 1⁄2 2 5 — — ⁄ 1 1⁄2 5 10 1⁄2 2 5 10 13 — — — — 15 15 10 10 — — — — 10 15 20 25 30 — — 15 25 30 15 20 — — — — 25 30 40 30 40 50 30 50 75 100 40 50 75 100 — — 2 2 1 3⁄4 1 3⁄4 — — — — 3 3 2 1⁄2 2 1⁄2 — — — 4 3 1⁄2 — 84CSA92BDF 84CSB92BDF 84CSD92BDF 84CSE92BDF 84DSA92BDF 84DSB92BDF 84DSD92BDF 84DSE92BDF 84DSF92BDF 84ESF92BDF 84ESG92BDF 84FSF92BDF 84FSH92BDF 84GSH92BDF 84GSJ92BDF 84HSJ92BDF 84HSK92BDF 84ISL92BDF 84JSM92BDF List Price $ 5660.00 5660.00 5660.00 5660.00 5754.00 5754.00 5754.00 5754.00 5754.00 6013.00 6013.00 7806.00 7806.00 11423.00 11423.00 12161.00 12161.00 17287.00 17976.00 Two Disconnect Switches with Ambient Compensated Bimetal Overload NEMA & General Purpose Control Max Hp Enclosure 200 Volts 230 Volts 460 Volts 3 7 1⁄2 10 10 15 25 30 40 3 5 7 1⁄2 10 10 15 15 25 20 30 30 50 40 75 50 100 575 Volts 5 10 15 25 30 50 75 100 NEMA Half Size Size 0 1 — — — 1 3⁄4 2 — — 2 1⁄2 3 — — 3 ⁄ 4 — 12 NEMA 12/3R NEMA 4 Painted NEMA 4/4X Stainless General Purpose Industrial Use Weatherproof Watertight Dust-tight Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Disc Amp Range Catalog Number 30 30 60 60 100 100 200 200 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-54 NEMA 1 List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 84CP92BDF81 84DP92BDF81 84EP92BDF81 84FP92BDF81 2327.00 2352.00 2610.00 3411.00 84CP920DF81 84DP920DF81 84EP920DF81 84FP920DF81 2714.00 2809.00 3067.00 4058.00 84CP92EDF81 84DP92EDF81 84EP92EDF81 84FP92EDF81 4075.00 4170.00 4428.00 6220.00 84CP92WDF81 84DP92WDF81 84EP92WDF81 84FP92WDF81 5582.00 5677.00 5936.00 7727.00 84GP92BDF81 84HP92BDF81 84IP92BDF81 84JP92BDF81 4944.00 5324.00 9089.00 9778.00 84GP920DF81 84HP920DF81 84IP920DF81 84JP920DF81 5780.00 6159.00 11406.00 12095.00 84GP92EDF81 84HP92EDF81 84IP92EDF81 84JP92EDF81 9838.00 10218.00 15344.00 16032.00 84GP92WDF81 84HP92WDF81 84IP92WDF81 84JP92WDF81 11345.00 12083.00 17210.00 17898.00 NEMA 12 is field convertible to NEMA 3/3R. For conduit hubs and conversion instructions, see page 16-87. available on standard alternator style ('92' in the catalog number). Not Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Duplex Heavy Duty Controllers Combination Circuit Breaker, Class 84 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Coil Table Standard coil voltage supplied will be 120V, separate control. For non-alternator styles (see factory modifications) change the 10th character using the coil table. Heater elements for bimetal overloads see page 16-148 (6-Required). Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-126. Wiring Diagrams see page 16-141. Replacement Parts see pages 16-155. 60Hz Voltage Letter 24 Separate Control 120 Separate Control 200–208 220–240 277 440–480 550–600 J F D G L H E 2 Motor Circuit Protectors (with Solid-State Overload) Max Hp Enclosure Overload 200 230 460 575 NEMA Half Amp Volts Volts Volts Volts Size Size Range ⁄ ⁄ ⁄ ⁄ 16 16 12 34 1⁄3 1⁄2 1 1⁄2 2 5 5 ⁄ 1⁄2 2 3 7 1⁄2 ⁄ 3⁄4 2 3 7 1⁄2 1⁄2 1 1⁄2 2 5 5 10 10 — — 15 15 10 10 — — — — 10 15 — — 15 25 30 20 25 30 15 20 — — — — 25 30 40 30 40 50 30 50 75 100 40 50 75 100 16 — 16 — ⁄ 13 — — — — 1 3⁄4 1 3⁄4 2 2 — — — — 2 1⁄2 2 1⁄2 3 3 — — — 3 1⁄2 4 — 0.25-1 0.75-3 2.5-10 9-18 0.25-1 0.75-3 2.5-10 9-18 13-27 13-27 20-40 13-27 22-45 22-45 30-60 30-60 45-90 57-115 67-135 NEMA 4 Painted NEMA 4/4X Stainless Industrial Use Weatherproof Watertight Dust-tight Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Motor Circuit Interrupter Catalog Number ETI 3 3 10 25 3 3 10 25 30 40 50 40 50 50 100 50 100 125 150 84CSA92BMF 84CSB92BMF 84CSD92BMF 84CSE92BMF 84DSA92BMF 84DSB92BMF 84DSD92BMF 84DSE92BMF 84DSF92BMF 84ESF92BMF 84ESG92BMF 84FSF92BMF 84FSH92BMF 84GSH92BMF 84GSJ92BMF 84HSJ92BMF 84HSK92BMF 84ISL92BMF 84JSM92BMF List Price $ 3015.00 3015.00 3015.00 3015.00 3110.00 3110.00 3110.00 3110.00 3110.00 3378.00 3378.00 4152.00 4152.00 5384.00 5384.00 5763.00 5763.00 11234.00 11923.00 Catalog Number 84CSA920MF 84CSB920MF 84CSD920MF 84CSE920MF 84DSA920MF 84DSB920MF 84DSD920MF 84DSE920MF 84DSF920MF 84ESF920MF 84ESG920MF 84FSF920MF 84FSH920MF 84GSH920MF 84GSJ920MF 84HSJ920MF 84HSK920MF 84ISL920MF 84JSM920MF List Price $ 3472.00 3472.00 3472.00 3472.00 3566.00 3566.00 3566.00 3566.00 3566.00 3825.00 3825.00 4798.00 4798.00 6220.00 6220.00 6599.00 6599.00 13543.00 14232.00 Catalog Number 84CSA92EMF 84CSB92EMF 84CSD92EMF 84CSE92EMF 84DSA92EMF 84DSB92EMF 84DSD92EMF 84DSE92EMF 84DSF92EMF 84ESF92EMF 84ESG92EMF 84FSF92EMF 84FSH92EMF 84GSH92EMF 84GSJ92EMF 84HSJ92EMF 84HSK92EMF 84ISL92EMF 84JSM92EMF List Price $ 4833.00 4833.00 4833.00 4833.00 4928.00 4928.00 4928.00 4928.00 4928.00 5186.00 5186.00 6962.00 6962.00 10277.00 10277.00 10656.00 10656.00 17489.00 18178.00 Catalog Number List Price $ 84CSA92WMF 84CSB92WMF 84CSD92WMF 84CSE92WMF 84DSA92WMF 84DSB92WMF 84DSD92WMF 84DSE92WMF 84DSF92WMF 84ESF92WMF 84ESG92WMF 84FSF92WMF 84FSH92WMF 84GSH92WMF 84GSJ92WMF 84HSJ92WMF 84HSK92WMF 84ISL92WMF 84JSM92WMF 6341.00 6341.00 6341.00 6341.00 6435.00 6435.00 6435.00 6435.00 6435.00 6694.00 6694.00 8468.00 8468.00 11785.00 11785.00 12523.00 12523.00 19355.00 20043.00 CONTROL PRODUCTS 2 3 — — — — — — — — — NEMA 12/3R General Purpose 16 2 3 0 0 0 0 1 1 1 1 1 NEMA 1 2 Motor Circuit Protectors (with Ambient Compensated Bimetal Overload) Max Hp Enclosure ⁄ 2 3 1⁄2 2 3 7 1⁄2 — 10 — 10 — 15 — 25 30 40 12 ⁄ 34 2 3 3⁄4 2 3 7 1⁄2 — 10 — 15 — 20 — 30 40 50 1 1⁄2 2 5 5 — — 1 1⁄2 2 5 5 10 10 — — 15 15 — — 15 20 25 25 30 30 — — 30 40 50 50 75 75 100 100 0 0 0 1 1 1 1 — — 2 2 — — 3 3 — 4 — — — — — — — 1 3⁄4 1 3⁄4 — — 2 1⁄2 2 1⁄2 — — 3 1⁄2 — 3 10 25 3 10 25 30 40 50 40 50 50 100 50 100 125 150 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA NEMA 12/3R NEMA 4 Painted NEMA 4/4X Stainless General Purpose Industrial Use Weatherproof Watertight Dust-tight Watertight, Dust-tight Corrosion Resistant 304 Stainless Steel Catalog Number List Price $ 84CPB92BMF81 2938.00 84CPD92BMF81 2938.00 84CPE92BMF81 2938.00 84DPB92BMF81 3032.00 84DPD92BMF81 3032.00 84DPE92BMF81 3032.00 84DPF92BMF81 3032.00 84EPF92BMF81 3291.00 84EPG92BMF81 3291.00 84FPF92BMF81 4075.00 84FPH92BMF81 4075.00 84GPH92BMF81 5307.00 84GPJ92BMF81 5307.00 84HPJ92BMF81 5687.00 84HPK92BMF81 5687.00 84IPL92BMF81 11157.00 84JPM92BMF81 11846.00 Catalog Number List Price $ Catalog Number 84CPB920MF81 3394.00 84CPB92EMF81 84CPD920MF81 3394.00 84CPD92EMF81 84CPE920MF81 3394.00 84CPE92EMF81 84DPB920MF81 3489.00 84DPB92EMF81 84DPD920MF81 3489.00 84DPD92EMF81 84DPE920MF81 3489.00 84DPE92EMF81 84DPF920MF81 3489.00 84DPF92EMF81 84EPF920MF81 3747.00 84EPF92EMF81 84EPG920MF81 3747.00 84EPG92EMF81 84FPF920MF81 4721.00 84FPF92EMF81 84FPH920MF81 4721.00 84FPH92EMF81 84GPH920MF81 6142.00 84GPH92EMF81 84GPJ920MF81 6142.00 84GPJ92EMF81 84HPJ920MF81 6522.00 84HPJ92EMF81 84HPK920MF81 6522.00 84HPK92EMF81 84IPL920MF81 13465.00 84IPL92EMF81 84JPM920MF81 14155.00 84JPM92EMF81 List Price $ 4755.00 4755.00 4755.00 4850.00 4850.00 4850.00 4850.00 5108.00 5108.00 6883.00 6883.00 10201.00 10201.00 10580.00 10580.00 17411.00 18100.00 Catalog Number List Price $ 84CPB92WMF81 84CPD92WMF81 84CPE92WMF81 84DPB92WMF81 84DPD92WMF81 84DPE92WMF81 84DPF92WMF81 84EPF92WMF81 84EPG92WMF81 84FPF92WMF81 84FPH92WMF81 84GPH92WMF81 84GPJ92WMF81 84HPJ92WMF81 84HPK92WMF81 84IPL92WMF81 84JPM92WMF81 6263.00 6263.00 6263.00 6358.00 6358.00 6358.00 6358.00 6616.00 6616.00 8391.00 8391.00 11709.00 11709.00 12446.00 12446.00 19278.00 19967.00 NEMA 12 is field convertible to NEMA 3/3R. For conduit hubs and conversion instructions, see page 16-87. Not available on standard alternator style ('92' in the catalog number). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-55 NEMA & General Purpose Control 200 230 460 575 NEMA Half Volts Volts Volts Volts Size Size Motor Circuit Interrupter ETI NEMA 1 Pump Control Panels Class 87, 88 General Application Features ▪ Fully Gasketed NEMA 3R Rainproof Enclosures ▪ 100,000 Amp Interrupting Capacity with Class R Fuses ▪ Heavy Duty NEMA Starters ▪ Solid State or Ambient Compensated Bimetal Overload Relays ▪ Heavy Duty Disconnect Handle ▪ Available in Reduced Voltage Versions ▪ Bold Pilot Legend on Front ▪ Generous Accessory Space ▪ Copper Grounding Lug For Three #6 Wires ▪ UL Listed for Outdoor Use and Service Equipment File #E14900 Heavy duty pump control panels are designed to withstand the most demanding environments. Typical applications include irrigation, agriculture, petrochemical, wastewater treatment and wherever motor control is challenged by harsh elements. Rugged pump control panels utilized cold forming “tox” process. They are more rainproof, sleet and ice resistant than in the past. Installation is easy. Panels are factory wired to provide flexible control and protect against short circuits and overloads. Ample space is provided for field modifications and installation of accessories. The pump control panels feature a full sized removable auxiliary panel for the mounting of accessories. The fusible version features fuse clips for full sized RK5 or compact class J fuses and accessory mounting space for the most commonly used accessories. Class 87 pump panels become jockey pump panels with the addition of a pressure switch. The jockey pump’s primary function is to maintain water pressure at a preset level and thus compensate for possible shortage of water in the pumping system. When the water pressure drops below the preset level, the pressure switch energizes the starter which in turn activates the jockey pump. The water pressure is then brought back up to the desired level. This insures the maintenance of proper water pressure at all times. Specified by Fortune 500 companies, ESP100 or thermal starters offer prolonged service under severe duty conditions. NEMA rated, these starters utilize large silver cadmium oxide contacts and wide copper heat sinks to ensure rapid heat dissipation and maximum electrical life. NEMA & General Purpose Control CONTROL PRODUCTS 16 Features 16-56 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ESP100 solid state overload relays provide phase loss protection for the motor by tripping within three seconds upon complete loss of one phase in a three phase circuit. Each overload has a 2:1 (4:1 in lower ranges) FLA adjustment range with an adjustment dial reading out in FLA. This feature allows for extreme fine tuning. Their heaterless construction minimizes energy costs and costs of cabinet ventilation or cooling. The class 87 pump panel comes with class 10 trip standard. The ambient compensated bimetal overload relays are designed to parallel thermal characteristics of typical pump motors. They prevent nuisance trips that may result from operation of the control in a higher ambient temperature than that at the pump. These relays are trip-free, tamperproof and can be set to reset automatically or manually. HOA and Start Pushbutton Every pump panel comes with an HOA and a start pushbutton. Half Size Starters Siemens motor matched starters feature all the rugged performance characteristics of our NEMA rated starter sizes, but are fractionally sized to more closely match your exact motor rating. As a result, significant economic savings are made possible without sacrificing the reliability you expect from a heavy duty starter. These additional starter sizes have the reserve capacity to handle occasional plugging and jogging without de-rating the device. Siemens motor matched can save hundreds, even thousands of dollars per project. Siemens motor matched starters comply with NEMA, UL and CSA standards. Pump Control Panels Class 87, 88 General Safety Disconnect Handle Up to three padlocks can be used to lock the disconnect in the OFF position. Maintenance work can be performed without hazard to personnel. External Reset The overload relay may be quickly reset by means of a button on the front of the enclosure. Bold Pilot Legend Provides positive indication of the selector switch position for use to stop the pump motor. Ground Lugs Insures proper connecting of ground wires and lightning arresters. UL Listed Assures proper construction throughout control panel. Reduced Voltage Available in part winding, wye delta and auto transformer types, these controls may be necessary where the power company limits the amount of current drawn from its lines, or where starting torque must be reduced. Fully gasketed NEMA 3/12 weatherproof enclosures are supplied with Class 88 reduced voltage starters. 16-57 NEMA & General Purpose Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog CONTROL PRODUCTS Part Winding Starters apply starting current in timed steps to minimize voltage fluctuations. Auto Transformer Starters maintain a closed circuit during transition and eliminate voltage or current surges. They draw less current than part winding starters and are well suited for starting motors over 20 Hp. Wye Delta starters and motors are used in areas where the power supply is inadequate to supply full starting current without objectionable voltage drop or for applications where low starting torque is required. Centrifugal pumps and similar apparatus requiring a low starting torque are typical applications. Both ends of all three windings of the wye delta motor are brought out so that they may be accessible for reconnecting from wye to delta. Auxiliary Equipment Pilot Lights are easily installed on the enclosure. Oil Tight and Heavy Duty, they meet NEMA A600 requirements. Lightning Arresters protect the control panel from lightning induced surges. Undervoltage and Phase Sensing Relays protect the pump against low voltage, voltage imbalance, loss of phase and phase reversal. Anti-Backspin Timers prevent the motor from starting during motor/shaft backspin. The TOX Box Siemens uses the TOX process to manufacture the enclosures for the pump panels. Advantages of the TOX process: ▪ Joints are 50-70% stronger ▪ Since the TOX process compresses the metal at the joint, it does not leave the high stresses in the metal ▪ Increased corrosion resistance. The protective layer on the metal is not damaged in the process, but instead flows with the material Class 87 NEMA Vacuum Starter Pump Control Panels The Siemens vacuum starter pump controllers are designed for the harshest environments. Typical environments include chemical, petrochemical, waste water treatment and mining. Contaminations present in these severe environments are detrimental to conventional air-break contacts decreasing their life expectancy and reliability. The Siemens vacuum starter pump controllers are well suited for these environments because the contacts are contained in hermetically sealed contact tubes. This prevents contaminates in the atmosphere from affecting the operation of the contacts. Additionally, neither arcs nor arcing gases are produced which dramatically increases the electrical endurance of the contacts. 16 Panels are predrilled for easy repositioning of the fuse trailer block to accommodate 250 and 600 volt fuses and full sized RK or compact J fuses. Circuit breakers are also available. New Heavy Duty Fusible Disconnect Switch The disconnect switch has been made even better to give you greater advantages: ▪ Visible blades for the highest level of safety ▪ Double Break Switching Action to reduce arcing, increase lifetime and eliminate the “electric hinge” ▪ Oversized lugs are standard ▪ Line side shield to help guard personnel from contact with live parts Motor Circuit Protector The motor circuit protector provides fast, accurate fault clearing that will minimize damage to the motor and control apparatus and protect branch circuit conductors. Continuous current ratings and adjustable trip ranges meet NEC requirements for full load and locked rotor currents. The adjustable instantaneous trip point can be set precisely to assure fault protection and eliminate nuisance tripping. Removable Door Enclosure door may be lifted off to make wiring easier. Mounting Flanges Convenient flanges at top and bottom of the enclosure provide easy mounting. They fit pole or flat surfaces using keyhole slots. Quarter Turn Latches Quarter turns are utilized to secure the door. Wind Catches A wind catch is provided to prevent the door from slamming shut (or open) due to high wind conditions. Pump Control Panels Standard Pump Panel with Solid State Overload, Class 87 Selection Coil Table Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-127. Wiring Diagrams see page 16-143. Replacement Parts see pages 16-155. Sizes 1-4 will be supplied standard with a 240/480 volt coil. To change the coil voltage, change the 8th character in the catalog number to the letter shown in the coil table. Sizes 5 & 6 will be supplied standard with a 480 volt coil. To change the coil voltage, change the 8th character in the catalog number to the letter shown in the coil table. 60Hz Voltage Letter 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 220–240/440–480 277 440–480 550–600 J F A D G C L H E NEMA & General Purpose Control CONTROL PRODUCTS 16 Fusible Disconnect Max HP 200V 230V 460V 575V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1 5 7 1⁄2 7 1⁄2 15 15 15 25 25 30 30 50 50 75 100 200 250 1 5 10 10 15 15 20 25 25 30 30 50 50 75 100 200 2 3 7 1⁄2 7 1⁄2 10 10 10 15 15 25 25 30 40 75 2 3 7 1⁄2 7 1⁄2 10 15 15 20 20 30 30 40 50 100 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — NEMA Size Half Size 1 1 1 1 — — — — — — 1 3⁄4 1 3⁄4 2 2 2 — — — — — 2 1⁄2 2 1⁄2 3 3 — — — 3 1⁄2 4 5 6 1 1 1 1 — — — — — — — — 1 3⁄4 2 2 — — — — 2 1⁄2 2 1⁄2 3 3 — — — 3 1⁄2 4 5 — — Overload Amp Range Disc Amp Rating 0.75-3 2.5-10 9-18 9-18 13-27 13-27 13-27 22-45 22-45 22-45 22-45 45-90 45-90 57-115 67-135 100-270 200-540 2.5-10 9-18 13-27 13-27 20-40 22-45 22-45 30-60 30-60 45-90 45-90 57-115 67-135 55-250 30 30 30 60 30 60 60 60 100 60 100 100 200 200 200 400 600 30 30 30 60 60 60 100 60 100 100 200 200 200 400 Fuse Clip Amps/Volts Catalog Number 30A/600V 30A/600V 30A/600V 60A/600V 30A/600V 60A/600V 60A/600V 60A/600V 100A/600V 60A/600V 100A/600V 100A/600V 200A/600V 200A/600V 200A/600V 400A/600V 600A/600V 30A/250V 30A/250V 30A/250V 60A/250V 60A/250V 60A/250V 100A/250V 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V 87DSB6FC 87DSD6FC 87DSE6FC 87DSE60C 87ESF6FC 87ESF60C 87FSF6FC 87FSH6FC 87FSH60C 87GSH6FC 87GSH60C 87HSK6FC 87HSK60C 87ISL6FC 87JSM6FC 87KSU6FH 87MSW6FH 87DSD6LC 87DSE6LC 87DSF6LC 87DSF6PC 87ESG6LC 87FSH6LC 87FSH6PC 87GSJ6LC 87GSJ6PC 87HSK6LC 87HSK6PC 87ISL6LC 87JSM6LC 87KSU6LH Catalog Number List Price $ 87DSB6MC 87DSC6MC 87DSD6MC 87DSE6MC 87DSF6MC 87ESF6MC 87ESG6MC 87FSF6MC 87FSH6MC 87GSH6MC 87GSJ6MC 87HSK6MC 87ISL6MC 87JSM6MC 87KST6MH 87KSU6MH 87MSW6MH 87MSX6MH 1430.00 1430.00 1430.00 1430.00 1430.00 1602.00 1602.00 1774.00 1774.00 2317.00 2317.00 2507.00 4962.00 5307.00 12070.00 12070.00 26168.00 30084.00 List Price $ 1137.00 1137.00 1137.00 1154.00 1336.00 1353.00 1533.00 1533.00 1629.00 2188.00 2284.00 2473.00 2653.00 4204.00 4549.00 9890.00 24970.00 1120.00 1120.00 1120.00 1137.00 1336.00 1508.00 1612.00 2128.00 2231.00 2421.00 2619.00 4170.00 4514.00 9683.00 Circuit Breaker Max HP 200V 230V 460V 575V NEMA Size 1/2 1 2 3 7 1⁄2 1/2 1 2 3 7 1⁄2 1 3 5 10 1 1 1 1 1 — — — — — — — 1 3 5 7 1⁄2 10 15 10 10 — — — — 1 3⁄4 1 3⁄4 — — 10 15 — — — 20 25 30 2 2 — 15 25 30 15 25 30 40 50 75 100 150 20 30 40 50 75 100 125 200 — — — — 2 1⁄2 2 1⁄2 50 75 100 150 200 250 400 50 75 100 200 200 300 400 — 15 3 — — 3 1⁄2 4 5 5 6 6 — — — — — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-58 Half Size Overload Amp Range 0.75-3 2.5-10 2.5-10 9-18 13-27 13-27 20-40 13-27 22-45 22-45 30-60 45-90 57-115 67-135 55-250 55-250 160-540 160-540 Not Motor Circuit Interrupter ETI Amps 3 10 10 25 30 40 50 40 50 50 100 100 125 150 250 400 400 600 available on Size 5 and larger. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog For an overload amp range of 0.25-1A, change the 5th character from a ‘B’ to an ‘A’. Discount Schedule NEMA Pump Control Panels Pump Panel with Ambient Compensated Bimetal Overload, Class 87 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil Table Heater elements for bimetal overloads see page 16-148 (6-Required). Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-127. Wiring Diagrams see page 16-143. Replacement Parts see pages 16-155. Sizes 1-4 will be supplied standard with a 230/480 volt coil. To change the coil voltage, change the 8th character in the catalog number to the letter shown in the coil table. Sizes 5 & 6 will be supplied standard with a 480 volt coil. To change the coil voltage, change the 8th character in the catalog number to the letter shown in the coil table. 60Hz Voltage Letter 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 220–240/440–480 277 440–480 550–600 J F A D G C L H E Fusible Disconnect 460V 575V NEMA Size Half Size — — — — — — — — — — — — — — — — — — — — — — — — 10 10 15 15 25 25 30 30 50 50 75 100 10 10 15 15 25 25 30 30 50 50 75 100 1 1 — — — — 1 3⁄4 1 3⁄4 2 2 — — — — 2 1⁄2 2 1⁄2 3 3 — — — 3 1⁄2 7 1⁄2 7 1⁄2 10 10 10 15 25 25 30 40 7 1⁄2 7 1⁄2 10 15 15 20 30 30 40 50 — — — — — — — — — — — — — — — — — — — — 4 1 1 — — — — 1 3⁄4 2 2 — — — 2 1⁄2 3 3 — — — 3 1⁄2 4 — Disc Amp Rating 30 60 30 60 60 100 60 100 100 200 200 200 30 60 60 60 100 100 100 200 200 200 Fuse Clip Amps/Volts Catalog Number 30A/600V 60A/600V 30A/600V 60A/600V 60A/600V 100A/600V 60A/600V 100A/600V 100A/600V 200A/600V 200A/600V 200A/600V 30A/250V 60A/250V 60A/250V 60A/250V 100A/250V 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 87DAE6FC 87DAE60C 87EAF6FC 87EAF60C 87FAJ6FC 87FAJ60C 87GAK6FC 87GAK60C 87HAN6FC 87HAN60C 87IAP6FC 87JAR6FC 87DAE6LC 87DAE6PC 87EAG6LC 87FAJ6LC 87FAJ6PC 87GAL6LC 87HAN6LC 87HAN6PC 87IAP6LC 87JAR6LC Catalog Number List Price $ List Price $ 1098.00 1116.00 1296.00 1314.00 1495.00 1589.00 2149.00 2244.00 2433.00 2614.00 4165.00 4510.00 1082.00 1098.00 1296.00 1469.00 1572.00 2192.00 2381.00 2580.00 4131.00 4475.00 CONTROL PRODUCTS 230V 16 Max HP 200V Circuit Breaker 200V 230V 460V 575V NEMA Size Half Size ⁄ 1 3 7 1⁄2 7 1⁄2 10 12 ⁄ 1 3 7 1⁄2 7 1⁄2 10 1 3 7 1⁄2 10 15 1 3 7 1⁄2 10 15 1 1 1 1 — — — — — — — — 1 3⁄4 1 3⁄4 15 25 30 20 25 30 2 2 — — — — — — 2 1⁄2 2 1⁄2 50 75 100 50 75 100 12 — — 10 15 — — 15 25 30 40 20 30 40 50 3 — — 3 1⁄2 4 — Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA Not Motor Circuit Interrupter ETI Amps 3 10 25 30 40 50 40 50 50 100 100 125 150 87DAA6MC 87DAB6MC 87DAD6MC 87DAE6MC 87EAF6MC 87EAG6MC 87FAH6MC 87FAJ6MC 87GAK6MC 87GAL6MC 87HAN6MC 87IAP6MC 87JAR6MC NEMA & General Purpose Control Max HP 1391.00 1391.00 1391.00 1391.00 1563.00 1720.00 1736.00 1736.00 2278.00 2278.00 2468.00 4923.00 5268.00 available on Size 5 or above. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-59 Reduced Voltage Pump Panels Auto Transformer & Part winding (2 Step) with Solid State Overload, Class 88 Coil and Control Voltage Ordering Information 䊳 䊳 䊳 䊳 䊳 Selection Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-127. Wiring Diagrams see page 16-143. Replacement Parts see pages 16-155. The coil voltage on the contactors will be the motor voltage. A CPT will be supplied to provide the control voltage. The control voltage will be 120V. To change the control voltage to customer supplied (no CPT included), change the 9th character to the following: for 24V , use ”J” for 120V, use ”F” Auto Transformer Type Fusible Disconnect Motor Max Voltage Hp 230 NEMA & General Purpose Control CONTROL PRODUCTS 16 460 15 20 30 40 50 75 100 200 25 30 50 75 100 150 200 400 OL amp range NEMA Half Size Size Fuse Clip Size Amps/Volts 22-45 30-60 45-90 57-115 67-135 100-210 100-270 200-540 22-45 22-45 45-90 57-115 67-135 55-250 55-250 160-540 2 — — 2 1⁄2 3 — — 3 1⁄2 4 5 5 6 2 — — — — — 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V — 400A/250V — 60A/600V 60A/600V 100A/600V 200A/600V 200A/600V — 400A/600V 600A/600V — 2 1⁄2 3 — — 3 1⁄2 4 5 5 6 — — — — Circuit Breaker Catalog Number List Price $ Circuit Breaker Amps Catalog Number List Price $ 88FSHT2FG 88GSJT2FG 88HSKT2FG 88ISLT2FG 88JSMT2FG — 88KSUT2FG — 88FSHT4FH 88GSHT4FH 88HSKT4FH 88ISLT4FH 88JSMT4FH — 88KSUT4FH 88MSXT4FH 7159.00 9683.00 10334.00 14680.00 15506.00 — 26853.00 — 7634.00 10045.00 10700.00 15179.00 16936.00 — 29592.00 43290.00 50 100 100 125 150 250 400 600 50 50 100 125 150 250 400 600 88FSHT2MG 88GSJT2MG 88HSKT2MG 88ISLT2MG 88JSMT2MG 88KSST2MG 88KSUT2MG 88MSXT2MH 88FSHT4MH 88GSHT4MH 88HSKT4MH 88ISLT4MH 88JSMT4MH 88KSST4MH 88KSUT4MH 88MSXT4MH 7254.00 9880.00 11320.00 16213.00 17042.00 26740.00 28706.00 48033.00 7757.00 10144.00 11230.00 16412.00 17446.00 27464.00 31032.00 48029.00 Part Winding 2 Step Fusible Disconnect Motor Max Voltage Hp OL amp range 230 20-40 22-45 30-60 45-90 57-115 67-135 100-210 100-270 13-27 22-45 30-60 30-60 57-115 67-135 55-250 55-250 460 20 25 40 50 60 75 125 150 30 40 60 75 100 150 250 350 NEMA Size Half Size Fuse Clip Size Amps/Volts 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V — 600A/250V 100A/600V 100A/600V 200A/600V 200A/600V 200A/600V 400A/600V — 600A/600V — 1 3⁄4 2 — — 2 1⁄2 3 — — 3 1⁄2 4 5 5 — — — — 1 3⁄4 2 — — 2 1⁄2 3 — — 3 1⁄2 4 5 5 — — — Circuit Breaker Catalog Number List Price $ Circuit Breaker Amps Catalog Number List Price $ 88ESGP2FG 88FSHP2FG 88GSJP2FG 88HSKP2FG 88ISLP2FG 88JSMP2FG — 88KSUP2FG 88ESFP4FH 88FSHP4FH 88GSJP4FH 88HSJP4FH 88ISLP4FH 88JSMP4FH — 88KSUP4FH 4282.00 4635.00 6548.00 7099.00 12578.00 13276.00 — 25672.00 4282.00 4635.00 6548.00 7099.00 12578.00 13276.00 — 25672.00 100 100 100 150 250 250 400 600 50 100 100 125 150 250 400 600 88ESGP2MG 88FSHP2MG 88GSJP2MG 88HSKP2MG 88ISLP2MG 88JSMP2MG 88KSSP2MG 88KSUP2MG 88ESFP4MH 88FSHP4MH 88GSJP4MH 88HSJP4MH 88ISLP4MH 88JSMP4MH 88KSSP4MH 88KSUP4MH 4014.00 4489.00 6376.00 6927.00 13543.00 14232.00 25078.00 26285.00 4014.00 4489.00 6376.00 6927.00 13543.00 14232.00 26285.00 47288.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-60 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Reduced Voltage Pump Panels Wye Delta with Solid State Overload, Class 88 Selection Coil and Control Voltage Ordering Information 䊳 䊳 䊳 䊳 䊳 Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-127. Wiring Diagrams see page 16-143. Replacement Parts see pages 16-155. The coil voltage on the contactors will be the motor voltage. A CPT will be supplied to provide the control voltage. The control voltage will be 120V. To change the control voltage to customer supplied (no CPT included), change the 9th character to the following: for 24V , use ”J” for 120V, use ”F” Wye Delta Open Transition Fusible Disconnect Motor NEMA Voltage Max Hp Size 200V 230V 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V 400A/250V 600A/250V — 60A/250V 60A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V 400A/250V 600A/250V — 60A/600V 60A/600V 100A/600V 200A/600V 200A/600V 200A/600V 400A/600V 400A/600V 600A/600V — 60A/600V 60A/600V 60A/600V 100A/600V 200A/600V 200A/600V 400A/600V 400A/600V 600A/600V — 50 100 100 125 150 250 250 400 600 800 50 50 100 100 150 250 250 400 600 1200 30 50 100 100 125 150 250 400 600 1200 30 50 50 100 125 150 250 400 400 1200 88DSF06FD 88ESG06FD 88FSH06FD 88GSJ06FD 88HSK06FD 88ISL06FD 88ISL06FD 88KSS06FD 88KSU06FD — 88DSF02FG 88ESG02FG 88FSH02FG 88GSJ02FG 88HSK02FG 88ISL02FG 88JSM02FG 88KSS02FG 88KSU02FG — 88DSE04FH 88ESF04FH 88FSH04FH 88GSJ04FH 88HSK04FH 88ISL04FH 88JSM04FH 88KSS04FH 88KSU04FH — 88DSE05FE 88ESF05FE 88FSF05FE 88GSH05FE 88HSJ05FE 88ISK05FE 88JSM05FE 88KSS05FE 88KSU05FE — 5384.00 6048.00 6892.00 8640.00 9304.00 16351.00 16351.00 25506.00 30833.00 — 5384.00 5952.00 6892.00 8640.00 9304.00 16351.00 16953.00 25506.00 30833.00 — 5384.00 5970.00 6548.00 8296.00 8296.00 14232.00 16953.00 25506.00 30833.00 — 5384.00 5970.00 6548.00 8296.00 9304.00 14232.00 14232.00 25506.00 30833.00 — Catalog Number 88DSF06MD 88ESG06MD 88FSH06MD 88GSJ06MD 88HSK06MD 88ISL06MD 88JSM06MD 88KSS06MD 88KSU06MD 88MSX06MD 88DSF02MG 88ESG02MG 88FSH02MG 88GSJ02MG 88HSK02MG 88ISL02MG 88JSM02MG 88KSS02MG 88KSU02MG 88MSX02MG 88DSE04MH 88ESF04MH 88FSH04MH 88GSJ04MH 88HSK04MH 88ISL04MH 88JSM04MH 88KSS04MH 88KSU04MH 88MSX04MH 88DSE05ME 88ESF05ME 88FSF05ME 88GSH05ME 88HSJ05ME 88ISK05ME 88JSM05ME 88KSS05ME 88KSU05ME 88MSX05ME List Price $ 5719.00 6022.00 6608.00 8744.00 9752.00 17463.00 18496.00 29820.00 30282.00 56221.00 5719.00 6022.00 6608.00 8744.00 9752.00 17463.00 18496.00 29820.00 30282.00 56221.00 5719.00 6022.00 6608.00 8744.00 9752.00 17463.00 18496.00 29820.00 30282.00 56221.00 5719.00 6022.00 6608.00 8744.00 9752.00 17463.00 18496.00 29820.00 30282.00 56221.00 Catalog Number 88DSFC6FD 88ESGC6FD 88FSHC6FD 88GSJC6FD 88HSKC6FD 88ISLC6FD 88ISLC6FD 88KSSC6FD 88KSUC6FD — 88DSFC2FG 88ESGC2FG 88FSHC2FG 88GSJC2FG 88HSKC2FG 88ISLC2FG 88JSMC2FG 88KSSC2FG 88KSUC2FG — 88DSEC4FH 88ESFC4FH 88FSHC4FH 88GSJC4FH 88HSKC4FH 88ISLC4FH 88JSMC4FH 88KSSC4FH 88KSUC4FH — 88DSEC5FE 88ESFC5FE 88FSFC5FE 88GSHC5FE 88HSJC5FE 88ISKC5FE 88JSMC5FE 88KSSC5FE 88KSUC5FE — Circuit Breaker List Price $ Catalog Number List Price $ 6944.00 7341.00 8167.00 10166.00 11269.00 18789.00 18789.00 34060.00 35141.00 — 6944.00 7245.00 8167.00 10166.00 11269.00 18789.00 20237.00 34060.00 35141.00 — 6944.00 7262.00 8348.00 10355.00 10355.00 19427.00 20995.00 34835.00 37009.00 — 6944.00 7262.00 8348.00 10355.00 12190.00 19427.00 19427.00 34835.00 37009.00 — 88DSFC6MD 88ESGC6MD 88FSHC6MD 88GSJC6MD 88HSKC6MD 88ISLC6MD 88JSMC6MD 88KSSC6MD 88KSUC6MD 88MSXC6MD 88DSFC2MG 88ESGC2MG 88FSHC2MG 88GSJC2MG 88HSKC2MG 88ISLC2MG 88JSMC2MG 88KSSC2MG 88KSUC2MG 88MSXC2MG 88DSEC4MH 88ESFC4MH 88FSHC4MH 88GSJC4MH 88HSKC4MH 88ISLC4MH 88JSMC4MH 88KSSC4MH 88KSUC4MH 88MSXC4MH 88DSEC5ME 88ESFC5ME 88FSFC5ME 88GSHC5ME 88HSJC5ME 88ISKC5ME 88JSMC5ME 88KSSC5ME 88KSUC5ME 88MSXC5ME 7280.00 7624.00 8219.00 10613.00 11716.00 20331.00 21779.00 33974.00 34590.00 66766.00 7280.00 7624.00 8219.00 10613.00 11716.00 20331.00 21779.00 33974.00 34590.00 66766.00 7280.00 7624.00 8408.00 10803.00 12639.00 21296.00 22537.00 34749.00 36458.00 66766.00 7280.00 7624.00 8408.00 10803.00 12639.00 21296.00 22537.00 34749.00 36458.00 66766.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-61 NEMA & General Purpose Control — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — List Price $ Fusible Disconnect CONTROL PRODUCTS 575V 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 MCP Catalog Amps Number Circuit Breaker 16 460V 10 15 20 30 40 50 60 75 150 300 10 15 25 30 50 60 75 100 150 350 15 30 40 60 75 100 150 200 300 700 15 30 40 60 75 100 150 200 300 700 Half Size Fuse Clip Amps/ Volts Closed Transition Vacuum Starter Pump Panels With Solid-State Overload Relay, Class 87 Selection Coil Table Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-127. Wiring Diagrams see page 16-143. Replacement Parts see pages 16-155. Sizes 4-6 will be supplied standard with a 480 volt coil. To change the coil voltage, change the 8th character in the catalog number to the letter shown in the coil table. 60Hz Voltage *** 24 Separate Control 120 Separate Control 200–208 220–240 277 440–480 550–600 J F D G L H E Fusible Disconnect Max Hp 460 Volts 100 200 575 Volts 100 200 NEMA Size 4 5 Overload Range 55-250A 55-250A Fuse Clip Amps/Volts 200A/600V 400A/600V Catalog Number 87JCM4F* 87KCU4F* List Price $ 7894.00 12707.00 575 Volts 100 200 300 400 NEMA Size 4 5 6 6 Overload Range 55-250A 55-250A 160-540A 160-540A Circuit Breaker Rating Amps 250A 400A 400A 600A Catalog Number 87JCM4M* 87KCT4M* 87MCW4M* 87MCX4M* List Price $ 8734.00 15002.00 33467.00 33467.00 Circuit Breaker NEMA & General Purpose Control CONTROL PRODUCTS 16 Max Hp 460 Volts 100 200 250 400 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-62 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Reduced Voltage Heavy Duty Starters Features and Benefits General Combination and non-combination reduced voltage starter sizes range from 0 to 6 including Siemens exclusive motormatched half-sizes. Enclosure types include 1, 3R/12, 4 painted and 4/4X stainless steel. All starters are UL listed and CSA certified. Auto Transformer Starter ▪ Maximum torque per amp ▪ Three coil auto transformer for balanced starting currents ▪ 50, 65 and 80% voltage taps ▪ Closed circuit transition ▪ Adjustable starting time ▪ ESP100 overload as standard ▪ CPT supplied as standard ▪ Wide range of factory modifications Wye-Delta Starter ▪ Lowest starting torque ▪ Closed or open circuit transition ▪ Adjustable starting time ▪ ESP100 overload as standard ▪ CPT supplied as standard ▪ Wide range of factory modifications Part-Winding Starter ▪ Simplest design – most economical ▪ Adjustable starting time ▪ ESP100 overload as standard ▪ CPT supplied as standard ▪ Wide range of factory modifications CONTROL PRODUCTS The reduced voltage starter: ▪ Reduces inrush current ▪ Provides smoother acceleration of the load ▪ Reduces starting torque ▪ Reduces stresses on mechanical linkages Characteristic Starting current drawn from line as % of that which would be drawn upon full voltage starting Starting current drawn by the motor Starting torque developed as % of that which would be developed on full voltage starting Smoothness of acceleration Part-Winding Wye-Delta 50% Tap 65% Tap 80% Tap 2 step 25% 42% 64% 65% 33% 50% 65% 80% 65% 58% 64% 40% 33% Third in order of Smoothness Second in order of Smoothness 5 seconds max. Limited by motor design 5-60 seconds Limited by motor design Fixed Fixed 25% 42% Increases slightly with speed Allowable accelerating times (typical) First in order of Smoothness 15 seconds at 200HP max. or 30 seconds on 200HP based on NEMA medium duty transformers Starting current and torque and adjustments Adjustable within limits of various taps NEMA & General Purpose Control Various Methods of Electro-Mechanical Reduced Voltage Motor Starting — A General Comparison Autotransformer Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16 Siemens manufactures the three commonly used electromechanical reduced voltage starters. Each one is designed for specific application requirements and consists of auto transformer, wye-delta and partwinding starters. 16-63 Reduced Voltage Heavy Duty Starters Auto Transformer with Solid State Overload, Class 36 & 37 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil and Control Voltage The coil voltage will always match the motor voltage. As standard, a CPT is supplied and 120V control voltage is utilized. To change to 120V separate control voltage (CPT not supplied), change the 9th character to “F”. To change to 24VAC separate control voltage (CPT not supplied), change the 9th character to “J”. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-125. Wiring Diagrams see page 16-136. Replacement Parts see page 16-155. For additional enclosure options see page 16-97. NEMA 1 General Purpose Enclosures Motor Volts 230 CONTROL PRODUCTS 16 200 NEMA & General Purpose Control 460 575 Max HP 10 10 15 25 30 40 50 75 150 10 15 20 30 40 50 75 100 200 15 25 30 50 75 100 150 200 400 15 25 30 50 75 100 200 400 NEMA Size — 2 — 3 — 4 5 5 6 — 2 — 3 — 4 5 5 6 — 2 — 3 — 4 5 5 6 — 2 — 3 — 4 5 6 Non-combination Overload Enclosures Half Amp Catalog List Size Range Number Price $ 13⁄4 — 21⁄2 — 31⁄2 — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 13–27 22–45 22–45 45–90 57–115 67–135 55–250 55–250 160–540 13–27 22–45 22–45 45–90 57–115 67–135 55–250 160–540 36ESGT6BD 36FSHT6BD 36GSJT6BD 36HSKT6BD 36ISLT6BD 36JSMT6BD — 36LTUT6BD 36MTXT6BD 36ESGT2BG 36FSHT2BG 36GSJT2BG 36HSKT2BG 36ISLT2BG 36JSMT2BG — 36LTUT2BG 36MTXT2BG 36ESFT4BH 36FSHT4BH 36GSHT4BH 36HSKT4BH 36ISLT4BH 36JSMT4BH — 36LTUT4BH 36MTXT4BH 36ESFT5BE 36FSHT5BE 36GSHT5BE 36HSKT5BE 36ISLT5BE 36JSMT5BE 36LTUT5BE 36MTXT5BE 4622.00 4923.00 5354.00 5784.00 10351.00 11178.00 — 19108.00 34218.00 4622.00 4923.00 5354.00 5784.00 10351.00 11178.00 — 19108.00 35442.00 4531.00 4923.00 5578.00 6233.00 10351.00 11385.00 — 20780.00 37544.00 4531.00 4923.00 5578.00 6233.00 10351.00 11385.00 20780.00 37544.00 Combination Non-Fusible Disconnect Catalog Number 37ESGT6BDD 37FSHT6BDD 37GSJT6BDD 37HSKT6BDD 37ISLT6BDD 37JSMT6BDD — 37LTUT6BDD 37MTXT6BDD 37ESGT2BGD 37FSHT2BGD 37GSJT2BGD 37HSKT2BGD 37ISLT2BGD 37JSMT2BGD — 37LTUT2BGD 37MTXT2BGD 37ESFT4BHD 37FSHT4BHD 37GSHT4BHD 37HSKT4BHD 37ISLT4BHD 37JSMT4BHD — 37LTUT4BHD 37MTXT4BHD 37ESFT5BED 37FSHT5BED 37GSHT5BED 37HSKT5BED 37ISLT5BED 37JSMT5BED 37LTUT5BED 37MTXT5BED Combination Fusible Disconnect Fuse List Clip Size Catalog List Price $ Amps/Volts Number Price $ 5656.00 5957.00 6663.00 7094.00 12160.00 12987.00 — 22347.00 41654.00 5656.00 5957.00 6663.00 7094.00 12160.00 12987.00 — 22347.00 42877.00 5656.00 5957.00 6887.00 7542.00 12160.00 13194.00 — 24019.00 44979.00 5656.00 5957.00 6887.00 7542.00 12160.00 13194.00 24019.00 44979.00 60A/250V 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V — 400A/250V 600A/250V 60A/250V 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V — 400A/250V 600A/250V 30A/600V 60A/600V 60A/600V 100A/600V 200A/600V 200A/600V — 400A/600V 600A/600V 30A/600V 60A/600V 60A/600V 100A/600V 200A/600V 200A/600V 400A/600V 600A/600V 37ESGT6BDF 37FSHT6BDF 37GSJT6BDF 37HSKT6BDF 37ISLT6BDF 37JSMT6BDF — 37LTUT6BDF 37MTXT6BDF 37ESGT2BGF 37FSHT2BGF 37GSJT2BGF 37HSKT2BGF 37ISLT2BGF 37JSMT2BGF — 37LTUT2BGF 37MTXT2BGF 37ESFT4BHF 37FSHT4BHF 37GSHT4BHF 37HSKT4BHF 37ISLT4BHF 37JSMT4BHF — 37LTUT4BHF 37MTXT4BHF 37ESFT5BEF 37FSHT5BEF 37GSHT5BEF 37HSKT5BEF 37ISLT5BEF 37JSMT5BEF 37LTUT5BEF 37MTXT5BEF 5794.00 6208.00 7112.00 7542.00 12539.00 14297.00 — 22658.00 41846.00 5794.00 6208.00 7112.00 7542.00 12539.00 14297.00 — 22658.00 43069.00 5794.00 6069.00 6991.00 7989.00 12539.00 14504.00 — 24328.00 45172.00 5794.00 6069.00 6991.00 7989.00 12539.00 14504.00 24328.00 45172.00 Motor Circuit Interrupter ETI Amps 50 50 100 100 125 150 250 400 600 50 50 100 100 125 150 250 400 600 40 50 50 100 125 150 250 400 600 40 50 50 100 125 150 250 600 Combination Circuit Breaker Catalog Number List Price $ 37ESGT6BDP 37FSHT6BDP 37GSJT6BDP 37HSKT6BDP 37ISLT6BDP 37JSMT6BDP 37LTST6BDP 37LTUT6BDP 37MTXT6BDP 37ESGT2BGP 37FSHT2BGP 37GSJT2BGP 37HSKT2BGP 37ISLT2BGP 37JSMT2BGP 37LTST2BGP 37LTUT2BGP 37MTXT2BGP 37ESFT4BHP 37FSHT4BHP 37GSHT4BHP 37HSKT4BHP 37ISLT4BHP 37JSMT4BHP 37LTST4BHP 37LTUT4BHP 37MTXT4BHP 37ESFT5BEP 37FSHT5BEP 37GSHT5BEP 37HSKT5BEP 37ISLT5BEP 37JSMT5BEP 37LTUT5BEP 37MTXT5BEP 5991.00 6405.00 6966.00 7417.00 13297.00 14125.00 24838.00 24838.00 42653.00 5991.00 6405.00 6966.00 7417.00 13297.00 14125.00 24838.00 24838.00 43875.00 5991.00 6405.00 7189.00 7844.00 13297.00 14331.00 26508.00 26508.00 45978.00 5991.00 6405.00 7189.00 7844.00 13297.00 14331.00 26508.00 45978.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-64 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Reduced Voltage Heavy Duty Starters 2 Step Part Winding with Solid State Overload, Class 36 & 37 Selection Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Coil and Control Voltage The coil voltage will always match the motor voltage. As standard, a CPT is supplied and 120V control voltage is utilized. To change to 120V separate control voltage (CPT not supplied), change the 9th character to “F”. To change to 24VAC separate control voltage (CPT not supplied), change the 9th character to “J”. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-125. Wiring Diagrams see page 16-136. Replacement Parts see page 16-155. For additional enclosure options see page 16-97. NEMA 1 General Purpose Enclosures Motor Volts Max HP 1 200 9–18 9–18 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 9–18 9–18 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 2.5–10 9–18 13–27 22–45 30–60 30–60 57–115 67–135 55–250 55–250 160–540 2.5–10 2.5–10 13–27 13–27 22–45 30–60 57–115 67–135 55–250 55–250 160–540 36CSEP6BD 36DSEP6BD 36ESGP6BD 36FSHP6BD 36GSJP6BD 36HSKP6BD 36ISLP6BD 36JSMP6BD — 36LTUP6BD 36CSEP2BG 36DSEP2BG 36ESGP2BG 36FSHP2BG 36GSJP2BG 36HSKP2BG 36ISLP2BG 36JSMP2BG — 36LTUP2BG 36MTXP2BG 36CSDP4BH 36DSEP4BH 36ESFP4BH 36FSHP4BH 36GSJP4BH 36HSJP4BH 36ISLP4BH 36JSMP4BH — 36LTUP4BH 36MTXP4BH 36CSDP5BE 36DSDP5BE 36ESFP5BE 36FSFP5BE 36GSHP5BE 36HSJP5BE 36ISKP5BE 36JSMP5BE — 36LTUP5BE 36MTXP5BE 1844.00 1965.00 2309.00 2766.00 3317.00 3868.00 7495.00 8185.00 — 17058.00 1844.00 1965.00 2309.00 2766.00 3317.00 3868.00 7495.00 8185.00 — 17058.00 35580.00 1844.00 1965.00 2309.00 2766.00 3317.00 3868.00 7495.00 8185.00 — 17058.00 35580.00 1844.00 1965.00 2309.00 2766.00 3317.00 3868.00 7495.00 8185.00 — 17058.00 35580.00 37CSEP6BDD 37DSEP6BDD 37ESGP6BDD 37FSHP6BDD 37GSJP6BDD 37HSKP6BDD 37ISLP6BDD 37JSMP6BDD — 37LTUP6BDD 37CSEP2BGD 37DSEP2BGD 37ESGP2BGD 37FSHP2BGD 37GSJP2BGD 37HSKP2BGD 37ISLP2BGD 37JSMP2BGD — 37LTUP2BGD 37MTXP2BGD 37CSDP4BHD 37DSEP4BHD 37ESFP4BHD 37FSHP4BHD 37GSJP4BHD 37HSJP4BHD 37ISLP4BHD 37JSMP4BHD — 37LTUP4BHD 37MTXP4BHD 37CSDP5BED 37DSDP5BED 37ESFP5BED 37FSFP5BED 37GSHP5BED 37HSJP5BED 37ISKP5BED 37JSMP5BED — 37LTUP5BED 37MTXP5BED 2877.00 2998.00 3342.00 4075.00 5126.00 5677.00 10734.00 11424.00 — 24492.00 2877.00 2998.00 3342.00 4075.00 5126.00 5677.00 10734.00 11424.00 — 24492.00 43445.00 2877.00 2998.00 3342.00 4075.00 5126.00 5677.00 10734.00 11424.00 — 24492.00 43445.00 2877.00 2998.00 3342.00 4075.00 5126.00 5677.00 10734.00 11424.00 — 24492.00 43445.00 60A/250V 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V — 600A/250V 60A/250V 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V — 600A/250V 1200A/250V 30A/600V 60A/600V 60A/600V 100A/600V 200A/600V 200A/600V 200A/600V 400A/600V — 600A/600V 1200A/600V 30A/600V 60A/600V 60A/600V 60A/600V 100A/600V 200A/600V 400A/600V 400A/600V 400A/600V 600A/600V 1200A/600V 37CSEP6BDF 37DSEP6BDF 37ESGP6BDF 37FSHP6BDF 37GSJP6BDF 37HSKP6BDF 37ISLP6BDF 37JSMP6BDF — 37LTUP6BDF 37CSEP2BGF 37DSEP2BGF 37ESGP2BGF 37FSHP2BGF 37GSJP2BGF 37HSKP2BGF 37ISLP2BGF 37JSMP2BGF — 37LTUP2BGF 37MTXP2BGF 37CSDP4BHF 37DSEP4BHF 37ESFP4BHF 37FSHP4BHF 37GSJP4BHF 37HSJP4BHF 37ISLP4BHF 37JSMP4BHF — 37LTUP4BHF 37MTXP4BHF 37CSDP5BEF 37DSDP5BEF 37ESFP5BEF 37FSFP5BEF 37GSHP5BEF 37HSJP5BEF 37ISKP5BEF 37JSMP5BEF 37LTSP5BEF 37LTUP5BEF 37MTXP5BEF 2903.00 3248.00 3938.00 4523.00 5505.00 6056.00 11036.00 11734.00 — 24686.00 2903.00 3248.00 3938.00 4523.00 5505.00 6056.00 11036.00 11734.00 — 24686.00 44540.00 2903.00 3024.00 3721.00 4178.00 5505.00 6056.00 11036.00 11734.00 — 24686.00 44540.00 2903.00 3024.00 3721.00 4178.00 5505.00 6056.00 11036.00 11734.00 24686.00 24686.00 44540.00 Motor Circuit Interrupter ETI Amps 30 50 100 100 125 150 250 400 600 600 30 50 100 100 100 150 250 250 400 600 1200 30 30 50 100 100 125 150 250 400 600 1200 30 30 50 50 100 125 150 250 — 400 1200 Combination Circuit Breaker Catalog Number List Price $ 37CSEP6BDP 37DSEP6BDP 37ESGP6BDP 37FSHP6BDP 37GSJP6BDP 37HSKP6BDP 37ISLP6BDP 37JSMP6BDP 37LTSP6BDP 37LTUP6BFP 37CSEP2BGP 37DSEP2BGP 37ESGP2BGP 37FSHP2BGP 37GSJP2BGP 37HSKPP2BGP 37ISLP2BGP 37JSMP2BGP 37LTSP2BGP 37LTUP2BGP 37MTXP2BGP 37CSDP4BHP 37DSEP4BHP 37ESFP4BHP 37FSHP4BHP 37GSJP4BHP 37HSJP4BHP 37ISLP4BHP 37JSMP4BHP 37LTSP4BHP 37LTUP4BHP 37MTXP4BHP 37CSDP5BEP 37DSDP5BEP 37ESFP5BEP 37FSFP5BEP 37GSHP5BEP 37HSJP5BEP 37ISKP5BEP 37JSMP5BEP — 37LTUP5BEP 37MTXP5BEP 3325.00 3446.00 3790.00 4376.00 6263.00 6814.00 13225.00 13914.00 25492.00 25492.00 3325.00 3446.00 3790.00 4376.00 6263.00 6814.00 13225.00 13914.00 25492.00 25492.00 47271.00 3325.00 3446.00 3790.00 4376.00 6263.00 6814.00 13225.00 13914.00 25492.00 25492.00 47271.00 3325.00 3446.00 3790.00 4376.00 6263.00 6814.00 13225.00 13914.00 — 25492.00 47271.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-65 NEMA & General Purpose Control 575 — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — Catalog Number Combination Fusible Disconnect Fuse List Clip Size Catalog List Price $ Amps/Volts Number Price $ CONTROL PRODUCTS 460 0 1 — 2 — 3 — 4 5 5 0 1 — 2 — 3 — 4 5 5 6 0 1 — 2 — 3 — 4 5 5 6 0 1 — 2 — 3 — 4 5 5 6 Combination Non-Fusible Disconnect 16 230 7 ⁄2 10 15 20 30 40 50 75 100 150 7 1⁄2 10 20 25 30 50 60 75 125 150 300 10 15 30 40 60 75 100 150 250 350 600 10 15 30 40 60 75 100 150 250 350 600 NEMA Size Non-combination Overload Enclosures Half Amp Catalog List Size Range Number Price $ Reduced Voltage Heavy Duty Starters Wye Delta, Open Transition with Solid State Overload, Class 36 & 37 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil and Control Voltage The coil voltage will always match the motor voltage. As standard, a CPT is supplied and 120V control voltage is utilized. To change to 120V separate control voltage (CPT not supplied), change the 9th character to “F”. To change to 24VAC separate control voltage (CPT not supplied), change the 9th character to “J”. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-125. Wiring Diagrams see page 16-138. Replacement Parts see page 16-155. For additional enclosure options see page 16-97. NEMA 1 General Purpose Enclosures Motor Volts 230 CONTROL PRODUCTS 16 200 NEMA & General Purpose Control 460 575 Max HP 10 15 20 30 40 50 60 75 150 300 10 15 25 30 50 60 75 100 150 350 15 30 40 60 75 100 150 200 300 700 15 30 40 60 75 100 150 200 300 700 NEMA Size Half Size Overload Amp Range 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 — 13⁄4 — 21⁄2 — 31⁄2 — — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — — 13⁄4 — 21⁄2 — 31⁄2 — — — — 13–27 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 13–27 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 9–18 13–27 22–45 22–45 45–90 57–115 67–135 55–250 55–250 160–540 9–18 13–27 13–27 22–45 30–60 57–115 67–135 55–250 55–250 160–540 Non-combination Enclosures Catalog Number 36DSF06BD 36ESG06BD 36FSH06BD 36GSJ06BD 36HSK06BD 36ISL06BD 36JSM06BD 36LTS06BD 36LTU06BD 36MTX06BD 36DSF02BG 36ESG02BG 36FSH02BG 36GSJ02BG 36HSK02BG 36ISL02BG 36JSM02BG 36LTS02BG 36LTU02BG 36MTX02BG 36DSE04BH 36ESF04BH 36FSH04BH 36GSJ04BH 36HSK04BH 36ISL04BH 36JSM04BH 36LTSS04BH 36LTU04BH 36MTX04BH 36DSE05BE 36ESF05BE 36FSF05BE 36GSH05BE 36HSJ05BE 36ISK05BE 36JSM05BE 36LTS05BE 36LTU05BE 36MTX05BE Combination Non-Fusible Disconnect List Catalog Price $ Number 2998.00 3266.00 3541.00 4342.00 5134.00 9632.00 10666.00 19143.00 19143.00 40922.00 2998.00 3266.00 3541.00 4342.00 5134.00 9632.00 10666.00 19143.00 19143.00 40922.00 2998.00 3266.00 3541.00 4342.00 5134.00 9632.00 10666.00 19143.00 19143.00 40922.00 2998.00 3266.00 3541.00 4342.00 5134.00 9632.00 10666.00 19143.00 19143.00 40922.00 37DSF06BDD 37ESG06BDD 37FSH06BDD 37GSJ06BDD 37HSK06BDD 37ISL06BDD 37JSM06BDD 37LTS06BDD 37LTU06BDD 37MTX06BDD 37DSF02BGD 37ESG02BGD 37FSH02BGD 37GSJ02BGD 37HSK02BGD 37ISL02BGD 37JSM02BGD 37LTS02BGD 37LTU02BGD 37MTX02BGD 37DSE04BHD 37ESF04BHD 37FSH04BHD 37GSJ04BHD 37HSK04BHD 37ISL040BHD 37JSM04BHD 37LTS04BHD 37LTU04BHD 37MTX04BHD 37DSE05BED 37ESF05BED 37FSF05BED 37GSH05BED 37HSJ05BED 37ISK05BED 37JSM05BED 37LTS05BED 37LTU05BED 37MTX05BED Combination Fusible Disconnect List Price $ 4031.00 4600.00 4850.00 5221.00 6944.00 11441.00 13904.00 25965.00 25965.00 48787.00 4031.00 4600.00 4850.00 5221.00 6944.00 11441.00 13904.00 25965.00 25965.00 48787.00 4031.00 4600.00 4850.00 5221.00 6944.00 11441.00 13904.00 25965.00 25965.00 48787.00 4031.00 4600.00 4850.00 5221.00 6944.00 11441.00 13904.00 21507.00 25965.00 48787.00 Fuse Clip Size Catalog Amps/Volts Number 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V 400A/250V 600A/250V 1200A/250V 60A/250V 60A/250V 100A/250V 200A/250V 200A/250V 200A/600V 400A/250V 400A/250V 600A/250V 1200A/250V 30A/600V 60A/600V 100A/600V 200A/600V 200A/600V 200A/600V 400A/600V 400A/600V 600A/600V 1600A/600V 30A/600V 60A/600V 100A/600V 100A/600V 200A/600V 200A/600V 400A/600V 400A/600V 600A/600V 1600A/600V 37DSF06BDF 37ESG06BDF 37FSH06BDF 37GSJ06BDF 37HSK06BDF 37ISL06BDF 37JSM06BDF 37LTS06BDF 37LTU06BDF 37MTX06BDF 37DSF02BGF 37ESG02BGF 37FSH02BGF 37GSJ02BGF 37HSK02BGF 37ISL02BGF 37JSM02BGF 37LTS02BGF 37LTU02BGF 37MTX02BGF 37DSE04BHF 37ESF04BHF 37FSH04BHF 37GSJ04BHF 37HSK04BHF 37ISL04BHF 37JSM04BHF 37LTS04BHF 37LTU04BHF 37MTX04BHF 37DSE05BEF 37ESF05BEF 37FSF05BEF 37GSH05BEF 37HSJ05BEF 37ISK05BEF 37JSM05BEF 37LTS05BEF 37LTU05BEF 37MTX05BEF List Price $ 4100.00 4669.00 5298.00 6875.00 7323.00 13611.00 14215.00 27490.00 27490.00 49880.00 4100.00 4669.00 5298.00 6875.00 7323.00 13611.00 14215.00 27490.00 27490.00 49880.00 4100.00 4669.00 4954.00 6531.00 7323.00 11820.00 14215.00 26770.00 26770.00 49880.00 4100.00 4669.00 4954.00 6531.00 7323.00 11820.00 14215.00 26770.00 26770.00 49880.00 Motor Circuit Interrupter ETI Amps 50 100 100 125 150 250 250 400 600 1200 50 50 100 100 150 250 250 400 600 1200 30 50 100 100 125 150 250 400 600 1200 30 50 50 100 125 150 250 250 400 1600 Combination Circuit Breaker Catalog Number List Price $ 37DSF06BDP 37ESG06BDP 37FSH06BDP 37GSJ06BDP 37HSK06BDP 37ISL06BDP 37JSM06BDP 37LTS06BDP 37LTU06BDP 37MTX06BDP 37DSF02BGP 37ESG02BGP 37FSH02BGP 37GSJ02BGP 37HSK02BGP 37ISL02BGP 37JSM02BGP 37LTS02BGP 37LTU02BGP 37MTX02BGP 37DSE04BHP 37ESF04BHP 37FSH04BHP 37GSJ04BHP 37HSK04BHP 37ISL04BHP 37JSM04BHP 37LTS04BHP 37LTU04BHP 37MTX04BHP 37DSE05BEP 37ESF05BEP 37FSF05BEP 37GSH05BEP 37HSJ05BEP 37ISK05BEP 37JSM05BEP 37LTS05BEP 37LTU05BEP 37MTX05BEP 4479.00 4782.00 5151.00 7289.00 8081.00 15360.00 16395.00 27577.00 27577.00 52611.00 4479.00 4782.00 5151.00 7289.00 8081.00 15360.00 16395.00 27577.00 27577.00 52611.00 4479.00 4782.00 5151.00 7289.00 8081.00 15360.00 16395.00 27577.00 27577.00 52611.00 4479.00 4782.00 5151.00 7289.00 8081.00 15360.00 16395.00 27577.00 27577.00 52611.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. 16-66 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Reduced Voltage Heavy Duty Starters Wye Delta, Closed Transition with Solid State Overload, Class 36 & 37 Ordering Information 䊳 䊳 䊳 䊳 䊳 䊳 Selection Coil and Control Voltage The coil voltage will always match the motor voltage. As standard, a CPT is supplied and 120V control voltage is utilized. To change to 120V separate control voltage (CPT not supplied), change the 9th character to “F”. To change to 24VAC separate control voltage (CPT not supplied), change the 9th character to “J”. Field Modification Kits see page 16-79. Factory Modifications see page 16-94. Dimensions see page 16-125. Wiring Diagrams see page 16-138. Replacement Parts see page 16-155. For additional enclosure options see page 16-97. NEMA 1 General Purpose Enclosures Motor Volts 200 10 15 20 30 40 50 60 75 150 300 10 15 25 30 50 60 75 100 150 350 15 30 40 60 75 100 150 200 300 700 15 30 40 60 75 100 150 200 300 700 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 1 — 2 — 3 — 4 5 5 6 — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — — 1 3⁄4 — 2 1⁄2 — 3 1⁄2 — — — — 13–27 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 13–27 20–40 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 9–18 13–27 22–45 30–60 45–90 57–115 67–135 55–250 55–250 160–540 9–18 13–27 13–27 22–45 30–60 57–115 67–135 55–250 55–250 160–540 Catalog Number List Price $ Catalog Number 36DSFC6BD 36ESGC6BD 36FSHC6BD 36GSJC6BD 36HSKC6BD 36ISLC6BD 36JSMC6BD 36LTSC6BD 36LTUC6BD 36MTXC6BD 36DSFC2BG 36ESGC2BG 36FSHC2BG 36GSJC2BG 36HSKC2BG 36ISLC2BG 36JSMC2BG 36LTSC2BG 36LTUC2BG 36MTXC2BG 36DSEC4BH 36ESFC4BH 36FSHC4BH 36GSJC4BH 36HSKC4BH 36ISLC4BH 36JSMC4BH 36LTSC4BH 36LTUC4BH 36MTXC4BH 36DSEC5BE 36ESFC5BE 36FSFC5BE 36GSHC5BE 36HSJC5BE 36ISKC5BE 36JSMC5BE 36LTSC5BE 36LTUC5BE 36MTXC5BE 4557.00 4858.00 5151.00 6212.00 7099.00 12501.00 13948.00 23450.00 23450.00 51467.00 4557.00 4858.00 5151.00 6212.00 7099.00 12501.00 13948.00 23450.00 23450.00 51467.00 4557.00 4858.00 5340.00 6401.00 8451.00 13465.00 14706.00 25320.00 25320.00 51467.00 4557.00 4858.00 5340.00 6401.00 8451.00 13465.00 14714.00 25320.00 25320.00 51467.00 37DSFC6BDD 37ESGC6BDD 37FSHC6BDD 37GSJC6BDD 37HSKC6BDD 37ISLC6BDD 37JSMC6BDD 37LTSC6BDD 37LTUC6BDD 37MTXC6BDD 37DSFC2BGD 37ESGC2BGD 37FSHC2BGD 37GSJC2BGD 37HSKC2BGD 37ISLC2BGD 37JSMC2BGD 37LTSC2BGD 37LTUC2BGD 37MTXC2BGD 37DSEC4BHD 37ESFC4BHD 37FSHC4BHD 37GSJC4BHD 37HSKC4BHD 37ISLC4BHD 37JSMC4BHD 37LTSC4BHD 37LTUC4BHD 37MTXC4BHD 37DSEC5BED 37ESFC5BED 37FSFC5BED 37GSHC5BED 37HSJC5BED 37ISKC5BED 37JSMC5BED 37LTSC5BED 37LTUC5BED 37MTXC5BED List Price $ 5591.00 5894.00 6462.00 8020.00 8908.00 15740.00 17186.00 30885.00 30885.00 59331.00 5591.00 5894.00 6462.00 8020.00 8908.00 15740.00 17186.00 30885.00 30885.00 59331.00 5591.00 5894.00 6651.00 8210.00 9829.00 16704.00 17944.00 32755.00 32755.00 59331.00 5591.00 5894.00 6651.00 8210.00 9829.00 16704.00 17944.00 32755.00 32755.00 59331.00 60A/250V 100A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V 400A/250V 600A/250V 1200A/250V 60A/250V 60A/250V 100A/250V 200A/250V 200A/250V 200A/250V 400A/250V 400A/250V 600A/250V 1200A/250V 30A/600V 60A/600V 100A/600V 200A/600V 200A/600V 200A/600V 400A/600V 400A/600V 600A/600V 1600A/600V 30A/600V 60A/600V 100A/600V 100A/600V 200A/600V 200A/600V 400A/600V 400A/600V 600A/600V 1600A/600V 37DSFC6BDF 37ESGC6BDF 37FSHC6BDF 37GSJC6BDF 37HSKC6BDF 37ISLC6BDF 37JSMC6BDF 37LTSC6BDF 37LTUC6BDF 37MTXC6BDF 37DSFC2BGF 37ESGC2BGF 37FSHC2BGF 37GSJC2BGF 37HSKC2BGF 37ISLC2BGF 37JSMC2BGF 37LTSC2BGF 37LTUC2BGF 37MTXC2BGF 37DSEC4BHF 37ESFC4BHF 37FSHC4BHF 37GSJC4BHF 37HSKC4BHF 37ISLC4BHF 37JSMC4BHF 37LTSC4BHF 37LTUC4BHF 37MTXC4BHF 37DSEC5BEF 37ESFC5BEF 37FSFC5BEF 37GSHC5BEF 37HSJC5BEF 37ISKC5BEF 37JSMC5BEF 37LTSC5BEF 37LTUC5BEF 37MTXC5BEF 5661.00 5962.00 6573.00 8399.00 9287.00 16050.00 17497.00 31797.00 31797.00 60425.00 5661.00 5962.00 6573.00 8399.00 9287.00 16050.00 17497.00 31797.00 31797.00 60425.00 5661.00 5962.00 6755.00 8589.00 10208.00 17014.00 18255.00 33667.00 33667.00 60425.00 5661.00 5962.00 6755.00 8589.00 10208.00 17014.00 18255.00 33667.00 33667.00 60425.00 Motor Circuit Interrupter ETI Amps 50 100 100 125 150 250 250 400 600 1200 50 50 100 100 150 250 250 400 600 1200 30 50 100 100 125 150 250 400 600 1200 30 50 50 100 125 150 250 250 400 1600 Combination Circuit Breaker Catalog Number List Price $ 37DSFC6BDP 37ESGC6BDP 37FSHC6BDP 37GSJC6BDP 37HSKC6BDP 37ISLC6BDP 37JSMC6BDP 37LTSC6BDP 37LTUC6BDP 37MTXC6BFP 37DSFC2BGP 37ESGC2BGP 37FSHC2BGP 37GSJC2BGP 37HSKC2BGP 37ISLC2BGP 37JSMC2BGP 37LTSC2BGP 37LTUC2BGP 37MTXC2BGP 37DSEC4BHP 37ESFC4BHP 37FSHC4BHP 37GSJC4BHP 37HSKC4BHP 37ISLC4BHP 37JSMC4BHP 37LTSC4BHP 37LTUC4BHP 37MTXC4BHP 37DSEC5BEP 37ESFC5BEP 37FSFC5BEP 37GSHC5BEP 37HSJC5BEP 37ISKC5BEP 37JSMC5BEP 37LTSC5BEP 37LTUC5BEP 37MTXC5BEP 6040.00 6384.00 6763.00 9157.00 10045.00 18230.00 19677.00 31884.00 31884.00 63156.00 6040.00 6384.00 6763.00 9157.00 10045.00 18230.00 19677.00 31884.00 31884.00 63156.00 6040.00 6384.00 6952.00 9347.00 10966.00 19195.00 20435.00 33753.00 33753.00 63156.00 6040.00 6384.00 6952.00 9347.00 10966.00 19195.00 20435.00 33753.00 33753.00 63156.00 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-67 NEMA & General Purpose Control 575 Half Size Combination Fusible Disconnect Fuse Clip Size Catalog List Amps/Volts Number Price $ CONTROL PRODUCTS 460 NEMA Size Combination Non-Fusible Disconnect 16 230 Max HP Overload Amp Range Non-combination Enclosures Lighting and Heating Control Electrically Held Lighting Contactors Features Application ▪ ▪ ▪ ▪ ▪ ▪ ▪ Siemens electrically held lighting contactors provide a safe, convenient means of local or remote switching for tungsten and ballast lamp loads, mercury arc lamps, and 3-phase resistive heating. Compact Design Silver Cadmium Oxide Contacts Pressure Type Terminals Straight Thru Wiring Wide Variety of Contact Configurations 12-Poles Maximum Available From 20 Amps–400 Amps Up to 12-Poles 20, 30 and 60 Amps 3-Poles On 100–400 Amps These lighting contactors are rated at 480V Tungsten, 600V Ballast. They are available in 2–12 poles with a variety of NO and NC contact arrangements. Typical applications include: ▪ Industrial and Commercial Buildings ▪ Stadiums ▪ Airports ▪ Non-Critical Resistive Heaters and other Non-Inductive Loads NEMA & General Purpose Control CONTROL PRODUCTS 16 ▪ Full Line of Enclosures NEMA 1 NEMA 3R/12 NEMA 4/4X (Stainless Steel) ▪ Available In Combination Form with Choice of: Fusible Disconnect Non-Fusible Disconnect Circuit Breaker All Combination Lighting Contactors ▪ are UL Service Entrance Listed ▪ Full Line of Factory And Field Modifications ▪ UL Listed Files #E14900 ▪ CSA Certified File LR 6535 Class LE electrically held lighting and heating contactors are used in applications where it is not critical that the contacts remain in the closed position during loss of control power. 16-68 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog General Lighting and Heating Control Electrically Held Lighting Contactors, Class LE Selection Ordering Information Coil Table Replace the *** with a number from the coil table. Field modifications see page 16-79. 왘 Factory modification kits see page 16-94. 왘 Dimensions see page 16-110 open page 16-128 enclosed. 왘 Wiring Diagrams see page 16-144. 왘 Replacement parts see page 16-158. 60Hz Voltage Number 24 120 208 240 277 480 600 024 120 208 240 277 480 600 왘 왘 Open and Non-combination Enclosed Contactors Open Type NEMA 1 Max. Amp Rating Number of Poles 2 3 4 6 20 8 9 30 60 Catalog Number List Price $ Catalog Number List Price $ Catalog Number 2 0 3 0 4 2 1 0 2 0 4 2 0 4 2 0 4 2 0 4 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 3 0 2 3 4 4 6 4 6 8 5 7 9 6 8 10 8 10 12 3 6 9 12 3 6 9 12 3 3 3 3 LEN00B200***A LEN00B002***A LEN00B300***A LEN00B003***A LEN00B400***A LEN00B202***A LEN00B103***A LEN00B004***A LEN00B204***A LEN00B006***A LEN00B404***A LEN00B206***A LEN00B008***A LEN00B405***A LEN00B207***A LEN00B009***A LEN00B406***A LEN00B208***A LEN00B010***A LEN00B408***A LEN00B210***A LEN00B012***A LEN00C003***A LEN00C006***A LEN00C009***A LEN00C012***A LEN00D003***A LEN00D006***A LEN00D009***A LEN00D012***A LEN00E003***A LEN00F003***A LEN00G003***A LEN00H003***A 242.00 242.00 268.00 268.00 344.00 344.00 344.00 344.00 448.00 448.00 612.00 612.00 612.00 664.00 664.00 664.00 715.00 715.00 715.00 819.00 819.00 819.00 293.00 603.00 914.00 1223.00 534.00 1154.00 1774.00 2395.00 861.00 2067.00 4506.00 12578.00 LEN01B200***A LEN01B002***A LEN01B300***A LEN01B003***A LEN01B400***A LEN01B202***A LEN01B103***A LEN01B004***A LEN01B204***A LEN01B006***A LEN01B404***A LEN01B206***A LEN01B008***A LEN01B405***A LEN01B207***A LEN01B009***A LEN01B406***A LEN01B208***A LEN01B010***A LEN01B408***A LEN01B210***A LEN01B012***A LEN01C003***A LEN01C006***A LEN01C009***A LEN01C012***A LEN01D003***A LEN01D006***A LEN01D009***A LEN01D012***A LEN01E003***A LEN01F003***A LEN01G003***A LEN01H003***A 268.00 268.00 293.00 293.00 371.00 371.00 371.00 371.00 534.00 534.00 698.00 698.00 698.00 750.00 750.00 750.00 801.00 801.00 801.00 905.00 905.00 905.00 310.00 621.00 930.00 1240.00 621.00 1240.00 1861.00 2481.00 1033.00 2430.00 5168.00 14232.00 LEN02B200***A LEN02B002***A LEN02B300***A LEN02B003***A LEN02B400***A LEN02B202***A LEN02B103***A LEN02B004***A LEN02B204***A LEN02B006***A LEN02B404***A LEN02B206***A LEN02B008***A LEN02B405***A LEN02B207***A LEN02B009***A LEN02B406***A LEN02B208***A LEN02B010***A LEN02B408***A LEN02B210***A LEN02B012***A LEN02C003***A LEN02C006***A LEN02C009***A LEN02C012***A LEN02D003***A LEN02D006***A LEN02D009***A LEN02D012***A LEN02E003***A LEN02F003***A LEN02G003***A LEN02H003***A List Price $ Catalog Number 414.00 414.00 440.00 440.00 517.00 517.00 517.00 517.00 621.00 621.00 784.00 784.00 784.00 853.00 853.00 853.00 919.00 919.00 919.00 1022.00 1022.00 1022.00 462.00 793.00 1120.00 1430.00 861.00 1644.00 2305.00 3004.00 1309.00 3231.00 7431.00 17635.00 LEN04B200***A LEN04B002***A LEN04B300***A LEN04B003***A LEN04B400***A LEN04B202***A LEN04B103***A LEN04B004***A LEN04B204***A LEN04B006***A LEN04B404***A LEN04B206***A LEN04B008***A LEN04B405***A LEN04B207***A LEN04B009***A LEN04B406***A LEN04B208***A LEN04B010***A LEN04B408***A LEN04B210***A LEN04B012***A LEN04C003***A LEN04C006***A LEN04C009***A LEN04C012***A LEN04D003***A LEN04D006***A LEN04D009***A LEN04D012***A LEN04E003***A LEN04F003***A LEN04G003***A LEN04H003***A List Price $ 554.00 554.00 651.00 651.00 728.00 728.00 728.00 728.00 758.00 758.00 925.00 925.00 925.00 976.00 976.00 976.00 1028.00 1028.00 1028.00 1147.00 1147.00 1147.00 702.00 991.00 1400.00 1788.00 1293.00 2140.00 2995.00 3904.00 1981.00 4036.00 8133.00 19616.00 For conduit hubs and conversion instructions, see page 16-87. be field assembled. Order mounting kit 49MCMPMA and required number of contactors. Example, 3, three pole contactors and 1 mounting plate for a 9-pole open assembly. Can Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-69 NEMA & General Purpose Control 100 200 300 400 3 6 9 12 3 6 9 12 3 3 3 3 Normally Open Contacts CONTROL PRODUCTS 12 Watertight, Dust-tight, Corrosion Resistant, 304 Stainless Steel Industrial Use Weatherproof Normally Closed Contacts 16 10 NEMA 4/4X Stainless Steel NEMA 12 NEMA 3/3R General Purpose Lighting and Heating Control Combination Electrically Held Lighting Contactors, Class LE Ordering Information Selection Coil Table Replace the *** with a number from the coil table. Field modification kits see page 16-79. 왘 Factory modifications see page 16-94. 왘 Dimensions see page 16-128. 왘 Wiring Diagrams see page 16-144. 왘 Replacement parts see page 16-155. 왘 왘 60Hz Voltage Number 24 120 208 240 277 480 600 024 120 208 240 277 480 600 Combination Lighting Contactors NEMA 12, NEMA 3/3R NEMA 4 Painted (thru 100 amps) NEMA 1 General Purpose Disconnect Type Non-Fusible Max. Amp Rating 20 30 60 100 200 300 20 30 60 Fusible 100 300 Circuit Breaker 20 30 60 100 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Disc Amp Rating Disc Amp/ Circuit Fuse Clip Breaker Rating Rating Catalog Number 30A 30A 60A 100A 200A 400A — — — — — — — — — — — — — — — — — — — — — — 30A/250V 30A/600V 30A/250V 30A/600V 60A/250V 60A/600V 100A/250V 100A/600V 200A/250V 200A/600V 400A/250V 400A/600V — — — — LEDB1B003***A LEDB1C003***A LEDD1D003***A LEDF1E003***A LEDH1F003***A LEDK1G003***A LEFA1B003***A LEFB1B003***A LEFA1C003***A LEFB1C003***A LEFC1D003***A LEFD1D003***A LEFE1E003***A LEFF1E003***A LEFG1F003***A LEFH1F003***A LEFJ1G003***A LEFK1G003***A LEBT1B003***A LEBV1C003***A LEBY1D003***A LEBZ1E003***A — — — — — — — — — — — — — — — — — — 20A 30A 60A 100A List Price $ 768.00 784.00 1233.00 2051.00 4006.00 8408.00 793.00 810.00 810.00 827.00 1266.00 1293.00 2137.00 2180.00 4152.00 4186.00 8650.00 8718.00 1077.00 1094.00 1533.00 2214.00 Industrial Use Weatherproof, Watertight, Dust-tight Watertight, Dust-tight, Corrosion Resistant 304 Stainless Steel Catalog Number List Price $ Catalog Number List Price $ LEDB2B003***A LEDB2C003***A LEDD2D003***A LEDF2E003***A LEDH2F003***A LEDK2G003***A LEFA2B003***A LEFB2B003***A LEFA2C003***A LEFB2C003***A LEFC2D003***A LEFD2D003***A LEFE2E003***A LEFF2E003***A LEFG2F003***A LEFH2F003***A LEFJ2G003***A LEFK2G003***A LEBT2B003***A LEBV2C003***A LEBY2D003***A LEBY2D003***A 855.00 991.00 1526.00 2430.00 5057.00 10958.00 880.00 898.00 1016.00 1033.00 1559.00 1586.00 2516.00 2559.00 5203.00 5237.00 11199.00 11269.00 1164.00 1301.00 1826.00 1826.00 LEDB4B003***A LEDB4C003***A LEDD4D003***A LEDF4E003***A LEDH4F003***A LEDK4G003***A LEFA4B003***A LEFB4B003***A LEFA4C003***A LEFB4C003***A LEFC4D003***A LEFD4D003***A LEFE4E003***A LEFF4E003***A LEFG4F003***A LEFH4F003***A LEFJ4G003***A LEFK4G003***A LEBT4B003***A LEBV4C003***A LEBY4D003***A LEBZ4E003***A 1512.00 1612.00 2507.00 4272.00 6849.00 15662.00 1512.00 1529.00 1637.00 1654.00 2542.00 2567.00 4359.00 4403.00 6996.00 7030.00 15903.00 15972.00 1796.00 1922.00 2809.00 4437.00 NEMA & General Purpose Control CONTROL PRODUCTS 16 200 Number of NO Poles NEMA 4/4X Stainless Steel For conduit hubs and conversion instructions, see page 16-87. 16-70 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Lighting and Heating Contractors Mechanically and Magnetically Held Lighting Contactors CLM 20 Amp CLM 100 Amp Operation (Magnetic Latch) A permanent magnet is built into the contactor structure of the 30A, 60A, 100A, and 200A contactors that will maintain the contactor in its energized state indefinitely without using control power. When energized, a DC current is applied that produces a magnetic field that reinforces the polarity of the permanent magnet, and the contactor pulls in immediately. The current to the coil is disconnected by the coil clearing interlock. In order to drop out the contactor, it is necessary to apply a field through the OFF coil in the reverse direction to the permanent magnet. This momentarily cancels the magnetic attraction and the contactor drops out. Coil and module failures are possible when used with solid state relays and PLC outputs. 24-volt systems are ok to use, but 120 volts and above should be discouraged. If higher values cannot be avoided, an interposing relay should be used. through control modules. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-71 NEMA & General Purpose Control (Mechanically Latched) The 300 & 400A lighting and heating contactors operate using a latching mechanism. Closing – When the “close” pushbutton is operated, the closing coil is energized, closing the contactor. As the contactor closes, the latch lever hooks over the latch pin to mechanically latch the contactor closed. The coil-clearing auxiliary contact de-energizes the closing coil. Opening – When the “Trip” pushbutton is operated, the trip solenoid coil is energized, unhooking the latch lever from the latch pin, which allows the contactor to open. As the contactor opens, the coil-clearing auxiliary contact de-energizes the trip solenoid coil. CONTROL PRODUCTS Operation Two Wire Control Module (Accessory 47) The advantages of two wire controls are: 1. Control station can have lower ampacity rating. 2. Control station can be located an extended distance from the CLM contactor. 3. Control module can frequently be controlled directly from microprocessor. 4. Control devices can be two wire single pole, single-throw types. 5. Control voltage may be different than the CLM coil circuit and at a lower voltage level. Note: If the control power to the solid state control module is lost while the module is energized the lighting contactor will open. If the line power to the lighting contactor is lost while the contactor is energized the contactor will not change state with return of line voltage. Power will be restored to the load if the control module is still energized. Control station should be the maintained type. Three Wire Control Module (Accessory 48) 1. The accessory 48 consists of two relays with contacts appropriately interconnected which provides for an interlocking that prevents both relays from being energized simultaneously. 2. This module has similar characteristics to the two wire module (Accessory 47) except there is no change of switch contact position upon loss of control line power. Control stations should be the momentary type. Selection Stop-Start Control Module (Accessory 49) Stop-start three wire maintained control is an arrangement used mostly when controlling motors, but can be used in lighting applications. Any number of momentary contact control stations consisting of normally open start buttons and normally closed stop buttons can be used. Start buttons are connected in parallel and stop buttons in series. 16 Mechanically Latched Lighting and Heating Contactor The CLM Lighting Contactors can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. They provide reliable and convenient lighting control in numerous applications, such as industrial plants, schools, hospitals, office buildings, shopping centers, airports, stadiums . . . literally everywhere lighting is required. The CLMs are listed under UL 508 with no derating when used open or enclosed. Combination lighting contactors are listed for UL service entrance. UL listed File #E60310 CSA Certified File LR 6535 Type CLM 20 Amp Lighting Contactor Solid State Control Modules The CLM 20 amp lighting contactor is an electromagnetically operated, mechanically latched three wire control contactor. The most commonly used method of control is a three position momentary contact switch with a center-off position. The controlling device must be able to make the coil inrush current but need not break it. The coil current is interrupted by the control contacts within the CLM contactor. Power for the control line may come from a separate source or directly from the line side of the CLM contactor. The CLM contactor can also be controlled by devices such as: ▪ Break-glass control stations ▪ Timers having single pole, double throw contacts ▪ Photo-electric cells ▪ Energy management systems ▪ Microprocessors ▪ Occupancy sensors Control modules make it possible to use a controlling device that does not have enough current-carrying capacity to control the CLM contactor directly. Control modules are also used when the control station is to be located at a distance greater than the allowable contactor line run. Another use for control modules occurs when the controlling device is only available as a single pole single-throw contact necessitating a two wire control line. Still another application for control modules is when start-stop three wire control is needed. Control modules also can make it possible to operate the CLM coil from its own incoming line at one voltage while providing the control at a second, perhaps lower voltage. Lighting Control Mechanically and Magnetically Held Lighting contactors, Class CLM Ordering Information 왘 왘 왘 왘 왘 왘 Selection Coil Table Replace *** with a number from the coil table. Field modification kits see page 16-79. Factory modifications see page 16-94. Dimensions see page 16-111 open page 16-128 enclosed. Wiring Diagrams see page 16-145. Replacement parts see page 16-158. 60Hz Voltage Number 24 120 208 240 277 480 600 024 120 208 240 277 480 600 Open and Non-combination Enclosed Contactors Open Type Enclosure NEMA 1 Max Amp Rating 20 CONTROL PRODUCTS 16 30 60 NEMA & General Purpose Control 100 200 300 400 NEMA 4/4X Stainless Steel NEMA 12 NEMA 3/3R General Purpose Watertight, Dust-tight, Corrosion Resistant, 304 Stainless Steel Industrial Use Weatherproof Number of Poles 2 3 4 6 8 10 12 2 3 4 5 6 8 9 10 12 2 3 4 5 6 8 9 10 12 2 3 4 5 2 3 4 5 2 3 2 3 Catalog Number see table below CLM0C02*** CLM0C03*** CLM0C04*** CLM0C05*** CLM0C06*** CLM0C08*** CLM0C09*** CLM0C10*** CLM0C12*** CLM0D02*** CLM0D03*** CLM0D04*** CLM0D05*** CLM0D06*** CLM0D08*** CLM0D09*** CLM0D10*** CLM0D12*** CLM0E02*** CLM0E03*** CLM0E04*** CLM0E05*** CLM0F02*** CLM0F03*** CLM0F04*** CLM0F05*** CLM0G02*** CLM0G03*** CLM0H02*** CLM0H03*** List Price $ Catalog Number CLM1B02*** CLM1B03*** CLM1B04*** see table CLM1B06*** below CLM1B08*** CLM1B10*** CLM1B12*** 429.00 CLM1C02*** 455.00 CLM1C03*** 481.00 CLM1C03*** 602.00 CLM1C05*** 1192.00 CLM1C06*** 1296.00 CLM1C08*** 1768.00 CLM1C09*** 1411.00 CLM1C10*** 1926.00 CLM1C12*** 830.00 CLM1D02*** 864.00 CLM1D03*** 1036.00 CLM1D04*** 1381.00 CLM1D05*** 2016.00 CLM1D06*** 2517.00 CLM1D08*** 3006.00 CLM1D09*** 2726.00 CLM1D10*** 3757.00 CLM1D12*** 1106.00 CLM1E02*** 1174.00 CLM1E03*** 1432.00 CLM1E04*** 1983.00 CLM1E05*** 2725.00 CLM1F02*** 2948.00 CLM1F03*** 3760.00 CLM1F04*** 4858.00 CLM1F05*** 4570.00 CLM1G02*** 4724.00 CLM1G03*** 10936.00 CLM1H02*** 12580.00 CLM1H03*** List Price $ 438.00 460.00 491.00 610.00 896.00 986.00 1121.00 446.00 471.00 471.00 618.00 1561.00 1666.00 2132.00 1782.00 1782.00 899.00 933.00 1106.00 1450.00 2523.00 3024.00 3505.00 3232.00 4256.00 1260.00 1329.00 1588.00 2139.00 3225.00 3639.00 4449.00 5547.00 5637.00 6189.00 13666.00 15312.00 Catalog Number CLM2B02*** CLM2B03*** CLM2B04*** CLM2B06*** CLM2B08*** CLM2B10*** CLM2B12*** CLM2C02*** CLM2C03*** CLM2C04*** CLM2C05*** CLM2C06*** CLM2C08*** CLM2C09*** CLM2C10*** CLM2C12*** CLM2D02*** CLM2D03*** CLM2D04*** CLM2D05*** CLM2D06*** CLM2D08*** CLM2D09*** CLM2D10*** CLM2D12*** CLM2E02*** CLM2E03*** CLM2E04*** CLM2E05*** CLM2F02*** CLM2F03*** CLM2F04*** CLM2F05*** CLM2G02*** CLM2G03*** CLM2H02*** CLM2H03*** List Price $ 543.00 567.00 592.00 711.00 1102.00 1193.00 1328.00 550.00 575.00 602.00 722.00 1584.00 1688.00 2152.00 1804.00 2310.00 1088.00 1122.00 1295.00 1639.00 2521.00 3022.00 3503.00 3231.00 4254.00 1485.00 1553.00 1811.00 2362.00 3965.00 4380.00 5447.00 6548.00 7533.00 8084.00 15993.00 17638.00 Catalog Number CLMSB02*** CLMSB03*** CLMSB04*** CLMSB06*** CLMSB08*** CLMSB10*** CLMSB12*** CLMSC02*** CLMSC03*** CLMSC04*** CLMSC05*** — — — — — CLMSD02*** CLMSD03*** CLMSD04*** CLMSD05*** — — — — — CLMSE02*** CLMSE03*** CLMSE04*** CLMSE05*** CLMSF02*** CLMSF03*** CLMSF04*** CLMSF05*** — — — — List Price $ 1046.00 1067.00 1080.00 1321.00 1533.00 1623.00 1759.00 757.00 783.00 808.00 929.00 — — — — — 1518.00 1553.00 1967.00 2311.00 — — — — — 2139.00 2208.00 2708.00 3259.00 4724.00 5138.00 6568.00 7893.00 — — — — Open 20 Amp Contactors Max Amp Rating 20 Contactors 110–120V Coil 50/60Hz Number of Poles Catalog Number 2 3 4 6 8 10 12 CLM22031 CLM32031 CLM42031 CLM62031 CLM82031 CLM102031 CLM122031 208–240V Coil 50/60Hz List Price $ Catalog Number with 2–6-poles will be assembled with all poles located in the top portion of the contactor. Contactors with 8–12-poles will be assembled with 6poles in the top portion and the remaining poles in the bottom portion of the contactor. 16-72 424.00 449.00 469.00 728.00 810.00 900.00 1035.00 CLM22061 CLM32061 CLM42061 CLM62061 CLM82061 CLM102061 CLM122061 265–277V Coil 50/60Hz List Price $ Catalog Number 424.00 449.00 469.00 728.00 810.00 900.00 1035.00 440–480V Coil 50/60Hz List Price $ Catalog Number CLM22071 CLM32071 CLM42071 CLM62071 CLM82071 CLM102071 CLM122071 24 volt coils are not available on 20, 300 and 400 amp contactor sizes. For 24 volt control of 20 amp contactor select solid state control module. For conduit hubs and conversion instructions, see page 16-87. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 424.00 449.00 469.00 728.00 810.00 900.00 1035.00 CLM22091 CLM32091 CLM42091 CLM62091 CLM82091 CLM102091 CLM122091 List Price $ 424.00 449.00 469.00 728.00 810.00 900.00 1035.00 CLM 30 & 60A 6-12-pole can be field assembled. Order mounting kit 49MCMPMA and the appropriate number of 2-5 pole contactors. 600 volt coils are not available on 20 amp contactors. Discount Schedule NEMA Lighting Control Combination Mechanically and Magnetically Held Lighting contactors, Class CLM Selection Ordering Information 왘 왘 왘 왘 왘 왘 Coil Table Replace *** with a number from the coil table. Field modification kits see page 16-79. Factory modifications see page 16-94. Dimensions see page 16-128. Wiring Diagrams see page 16-145. Replacement parts see page 16-158. 60Hz Voltage Number 24 120 208 240 277 480 600 024 120 208 240 277 480 600 Combination Lighting Contactors Enclosure NEMA 12, NEMA 3/3R NEMA 4 Painted (thru 100 amps) NEMA 1 General Purpose Disconnect Type Non-Fusible Contactor Amp Rating Number of NO Poles 20 30 60 100 200 300 20 30 60 Fusible 100 300 20 30 60 100 200 300 Circuit Breaker 30A 30A 60A 100A 200A 400A — — — — — — — — — — — — — — — — — — — — — — — — 30A/250V 30A/600V 30A/250V 30A/600V 60A/250V 60A/600V 100A/250V 100A/600V 200A/250V 200A/600V 400A/250V 400A/600V — — — — — — Circuit Breaker Rating Catalog Number List Price $ — — — — — — — — — — — — — — — — — — 20A 30A 60A 100A 200A 300A CMNB14*** CMNC14*** CMND15*** CMNE16*** CMNF17*** CMNG18*** CMFB10*** CMFB11*** CMFC10*** CMFC11*** CMFD12*** CMFD13*** CMFE14*** CMFE15*** CMFF16*** CMFF17*** CMFG18*** CMFG19*** CMBB14*** CMBC15*** CMBD18*** CMBE18*** CMBF10*** CMBG11*** 768.00 784.00 1233.00 2051.00 3990.00 8408.00 793.00 810.00 810.00 827.00 1266.00 1293.00 2137.00 2180.00 4152.00 4186.00 8650.00 8718.00 1077.00 1094.00 1533.00 1533.00 4944.00 10898.00 Catalog Number Catalog Number List Price $ CMNB24*** CMNC24*** CMND25*** CMNE26*** CMNF27*** CMNG28*** CMFB20*** CMFB21*** CMFC20*** CMFC21*** CMFD22*** CMFD23*** CMFE24*** CMFE25*** CMFF26*** CMFF27*** CMFG28*** CMFG29*** CMBB24*** CMBC25*** CMBD28*** CMBE28*** CMBF20*** CMBG21*** 855.00 991.00 1526.00 2430.00 5057.00 10958.00 880.00 898.00 1016.00 1033.00 1559.00 1586.00 2516.00 2559.00 5203.00 5237.00 11199.00 11269.00 1164.00 1301.00 1826.00 2594.00 5997.00 12793.00 List Price $ CMNBS4*** CMNCS4*** CMNDS5*** CMNES6*** CMNFS7*** CMNGS8*** CMFBS0*** CMFBS1*** CMFCS0*** CMFCS1*** CMFDS2*** CMFDS3*** CMFES4*** CMFES5*** CMFFS6*** CMFFS7*** CMFGS8*** CMFGS9*** CMBBS4*** CMBCS5*** CMBDS8*** CMBES8*** CMBFS0*** CMBGS1*** 1486.00 1612.00 2507.00 4272.00 6849.00 15662.00 1512.00 1529.00 1637.00 1654.00 2542.00 2567.00 4359.00 4403.00 6996.00 7030.00 15903.00 15972.00 1796.00 1922.00 2809.00 4437.00 7788.00 18151.00 NEMA & General Purpose Control Lighting & Heating Contactor Ratings CLM Maximum AC/DC Voltage and Amp Ratings Load Type Poles to Load Amperes 2 for 1-Phase Continuous 1 for 1-Phase 3 for 3-Phase Tungsten Ballast General General 20 20 30 20 250V AC 347V AC 347V AC 125V DC 250V AC 600V AC 600V AC 250V DC Contactor Ratings Load Amperes Max Volts Type Continuous Line to Line Tungsten Ballast Heating 30-400 30-400 30-400 480 600 600 Max Volts Line to Neutral 277 346 346 Inrush Current Over Fuse Size (amps RMS) at AC Control Voltage 20A CLM Amps Inrush Fuse 120V 5.0 2.0 240V 2.5 1.0 277V 2.2 1.0 24 347V 1.8 0.75 Inrush VA Dropout VA 20 30 60 60 100/200 100/200 300/400 625 410 410 600 900 1300 1600 6 40 40 40 200 130 550 480V 1.3 0.5 volt coils are not available on 20 and 300 amp contactors. Use solid state control module on 20 amp size. Discount Schedule NEMA AC Coil Data Contactor Amperes No. Poles 2-12 2-5 2-3 4-5 2-3 4-5 2-3 For conduit hubs and conversion instructions, see page 16-87. CONTROL PRODUCTS 200 Disc Amp/ Fuse Clip Rating Watertight, Dust-tight, Corrosion Resistant, 304 Stainless Steel 16 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Disc Amp Rating NEMA 4/4X Stainless Steel Industrial Use Weatherproof, Watertight, Dust-tight 600 volt coils are not available on 20 amp contactors. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-73 Industrial Control Power Transformers Class MT General NEMA & General Purpose Control CONTROL PRODUCTS 16 Features ▪ Epoxy-encapsulated (50–5000VA); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments ▪ Fuse clips (most models). Factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add-on fuse block or kit ▪ Integrally molded barriers. Between terminals and transformer, protect against electrical creepage. Up to 30% greater terminal contact area permits low-loss connections. Extra-deep barriers reduce the chance of shorts from frayed leads or careless wiring ▪ Terminals. Molded into the transformer, are difficult to break during wiring. A full quarter-inch of thread on the 10-32 terminal screws prevents stripping and pullout ▪ Jumpers supplied. Two jumper links are standard with all transformers which can be wired for dual primary voltages Operation Industrial control circuits and motor control loads typically require more current when they are initially energized than under normal operating conditions. This period of high current demand, referred to as inrush, may be as great as ten times the current required under steady state (normal) operating conditions, and can last up to 40 milliseconds. A transformer in a circuit subject to inrush will typically attempt to provide the load with the required current during the inrush period. However, it will be at the expense of the secondary voltage stability by allowing the voltage to the load to decrease as the current increases. This period of secondary voltage instability, resulting from increased current, can be of such magnitude that the transformer is unable to supply sufficient voltage to energize the load. The transformer must therefore be designed and constructed to accommodate the high inrush current, while maintaining secondary voltage stability. According to NEMA standards, the secondary voltage would typically be at 85% of the rated voltage. 16-74 Industrial Control Power Transformers are specifically designed and built to provide adequate voltage to the load while accommodating the high current levels present at inrush. These transformers deliver excellent secondary voltage regulation and meet or exceed the standards established by NEMA, ANSI, UL and CSA. Their rugged construction and excellent electrical characteristics ensure reliable operation of electromagnetic devices and trouble-free performance. Specifications ▪ Laminations are built with silicon steel to minimize core losses and to increase optimum performance and efficiency ▪ Copper magnet wire of the highest quality assures efficient operation ▪ Factory mounted type “K” fuse clips are standard on all secondary transformers where possible ▪ Two jumper links are standard with all transformers which can be wired for dual primary voltages ▪ UL listed and CSA certified ▪ 50/60 Hz rated ▪ Insulation materials are of the highest rating available for the temperature class Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog ▪ Mounting brackets are heavy gauge steel to add strength to core construction and provide stable mounting. Slotted mounting feet permit easy installation ▪ Attractive black finish; easy-to-read nameplate with complete rating data and wiring diagram ▪ Class 105°C (221°F) insulation system. 55°C (131°F) temperature rise. (50 – 750VA typical) ▪ Class 180°C (356°F) insulation system. 120°C (248°F) temperature rise. (1000 – 5000VA typical) ▪ Optional field mounted 2-pole primary Class CC fuse block is available Industrial Control Power Transformers Class MTG General the covers prevent contact with current carrying parts on the transformer and are available for 4 terminal configurations. The international fuse block kits have inherent touch safe terminals and fuse clips. Siemens Meets International Standards CSA (Canadian Standards Association) was utilized as a Competent Body in reviewing, interpreting and properly complying with the requirements of IEC-742 to place a CE mark on its MTG Series product. As a National Certification Body, CSA also has the proper documentation and reports on file for MTG Series to utilize the CB Scheme ensuring acceptance throughout the world. The standard Siemens MTG product is available with terminal covers which meets the requirements of IEC-529, IP20 degree of protection and meets the applicable requirements for covers per IEC-742. Features The IP specification which most closely approximates protection to a human finger is IP20. This IP rating would be the most common degree of touch-proof connection for electrical components such as transformers. EN 61 558 The requirements for industrial control transformers to be used in the European Common Market are identified by the IEC and specified in EN 61 558, Safety of Power Control Transformers, under Low Voltage Directive 73/23/EEC. CE mark on the product indicates compliance. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-75 NEMA & General Purpose Control IEC-529 The requirements for finger-safe or touch-proof electrical connections are identified by the International Electrotechnical Commission (IEC) under specification 529, Classification of Degrees of Protection Provided by Enclosures. These various degrees of protection are identified and differentiated by IP ratings. CONTROL PRODUCTS ▪ Winding to winding insulation requirements may be twice that for IEC-742 compared to UL506 ▪ The electrical clearances between current carrying parts are one-third greater to comply with IEC-742 requirements for units up to 250VA with voltages up to 440 volts ac ▪ Transformers manufactured to IEC-742 requirements will have a minimum of 10% higher overload capacity than those manufactured only to UL506 requirements While no requirement exists in IEC-742 for the electrical connections to be either finger safe or touch proof, the specification does state that IF a transformer is supplied with a cover to prevent incidental contact with current carrying parts, that cover must utilize two separate methods or places of securing it to the component, with neither being dependent upon the other. Additionally, one of these methods MUST require a tool to remove it. 16 ▪ Class MTG Industrial Control Transformers are 100% certified for all domestic and International Applications ▪ The MTG line has full compliance with IEC Safety standards EN 61 558 ▪ CE Mark in accordance with requirements for EN 61 558 ▪ Meets IP-20 specifications per IEC 529 for finger-safe protection when used with Siemens Touch Safe snap on terminal cover kits. Meets IP-00 specifications when covers are not used. ▪ UL Listed (File # E46323) ▪ CSA Certified (File #LR27533) ▪ Exceeds applicable requirements for control transformers as determined by NEMA and ANSI ▪ Insulation requirements is twice that of UL506 ▪ Proven Epoxy-encapsulated coils operate cooler and completely seal the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments ▪ Available in 50 to 750 VA sizes, in all standard voltage combinations ▪ Class 105°C (221°F) insulation system. 55°C (131°F) temperature rise. (50 –750VA typical) ▪ Class 180°C (356°F) insulation system. 120°C (248°F) temperature rise. (1000–5000VA typical) ▪ Primary and secondary fusing capability available as field installed kits for domestic or international fusing ▪ Integrally-molded terminals and barriers between terminals make breakage virtually impossible during wiring. The MTG transformer construction is the same as our high quality Class MT transformers Optional Field Installed Fuse Clip Kits For Panel Mounting ▪ 2-Pole primary Class CC fuse block 13 1 ▪ 1-Pole secondary midget fuse block for ⁄32 ҂ 1 ⁄2 fuses ▪ 2-Pole primary international type fuse blocks ▪ 1-Pole secondary international type fuse blocks Optional Touch-Safe Snap-On Terminal Cover Kits The Touch-Safe terminal covers are designed to comply with IEC 742 and IP 20 requirements. When installed, IEC-742 The requirements for industrial control circuit transformers to be used in the European Common Market are identified by the International Electrotechnical Commission (IEC) and specified under IEC-742, Non-Short Circuit Proof Isolating Transformers, under the Low Voltage Directive 73/23/EEC. Manufacturers of control transformers indicate compliance with these requirements by placing a CE mark on the product. Industrial Control Power Transformers Class MT, MTG Transformer Selection Process Selecting a transformer for industrial control circuit applications requires knowledge of the following terms: Inrush VA is the product of load voltage (V) multiplied by the current (A) that is required during circuit start-up. It is calculated by adding the inrush VA requirements of all devices (contactors, timers, relays, pilot lights, solenoids, etc.), which will be energized together. Inrush VA requirements are best obtained from the component manufacturer. 16 Primary Voltage is the voltage available from the electrical distribution system and its operational frequency, which is connected to the transformer supply voltage terminals. CONTROL PRODUCTS Sealed VA is the product of load voltage (V) multiplied by the current (A) that is required to operate the circuit after initial start-up or under normal operating conditions. It is calculated by adding the sealed VA requirements of all electrical components of the circuit that will be energized at any given time. Sealed VA requirements are best obtained from the component manufacturer. Sealed VA is also referred to as steady state VA. Secondary Voltage is the voltage required for load operation which is connected to the transformer load voltage terminals. General Once the circuit variables have been determined, transformer selection is a simple 5-step process as follows: 1. Determine the Application Inrush VA by using the following industry accepted formula: ——————————– Application Inrush VA = √(Inrush VA)2 ѿ (Sealed VA)2 2. Refer to the Regulation Data Chart. If the primary voltage is basically stable and does not vary by more than 5% from nominal, the 90% secondary voltage column should be used. If the primary voltage varies between 5% and 10% of nominal, the 95% secondary voltage column should be used. 3. After determining the proper secondary voltage column, read down until a value equal to or greater than the Application Inrush VA is found. In no case should a figure less than the Application Inrush VA be used. 4. Read left to the Transformer VA Rating column to determine the proper transformer for this application. As a final check, make sure that the Transformer VA Rating is equal to or greater than the total sealed requirements. If not, select a transformer with a VA rating equal to or greater than the total sealed VA. 5. Refer to the following pages to determine the proper catalog number based on the transformer VA, and primary and secondary voltage requirements. Regulation Data Chart Transformer VA Ratings Inrush VA At 20% Power Factor NEMA/IEC NEMA/IEC 95% Sec 90% Sec Voltage Voltage NEMA/IEC 85% Sec Voltage 25 50 75 100 150 200 250 300 350 500 750 1000 1000 1500 2000 3000 5000 100/––– 170/190 310/350 370/410 780/860 810/900 1400/1540 1900/2090 3100/3410 4000/4400 8300/9130 15000/––– 9000/––– 10500/––– 17000/––– 24000/––– 55000/––– 150/––– 240/270 540/600 730/810 1150/1270 1450/1600 2300/2530 3850/4240 4800/5280 7000/7700 14000/15400 27000/––– 18500/––– 205000/––– 34000/––– 47500/––– 115000/––– 130/––– 200/220 410/460 540/600 930/1030 1150/1270 1900/2090 2700/2970 3650/4020 5300/5830 11000/12100 21000/––– 13000/––– 15000/––– 25500/––– 36000/––– 92500/––– NEMA & General Purpose Control To comply with NEMA standards, which require all magnetic devices to operate successfully at 85% of rated voltage, the 90% secondary voltage column is most often used in selecting a transformer. For For units with Class 105°C insulation systems. units with Class 180°C insulation systems. Fuse Clip Kit KCCFPX2R Primary Fuse Kit In addition to factory installed secondary fusing, Siemens offers a primary fuse kit for class MT transformers size 50–750 VA for field installation. The primary fuse kit includes a 2-pole Class CC fuse block, instructions and all associated mounting and wiring hardware. Additionally, this fuse kit will fit most competitors’ units. To order this kit, use catalog number KCCFPX2R. The primary fuse kit, when installed, will add a maximum of 0.69 in. (18 mm) to the transformer “A” dimension and 1.94 in. (49 mm) to the “C” dimension. 16-76 Primary Fuse Kit Installation—Class MT Transformer with Primary Fuse Kit, KCCFPX2R Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Industrial Control Power Transformers Domestic, Class MT Selection Ordering Information 왘 왘 왘 왘 Use the Voltage Table to determine the primary and secondary voltage required. Field Modifications see page 16-79. Dimensions see page 16-113. Wiring Diagrams see page 16-147. Voltage Letter A MT0050A MT0075A MT0100A MT0150A MT0200A MT0250A MT0300A MT0350A MT0500A MT0750A MT1000A MT1500A MT2000A MT3000A MT5000A List Price $ 46.00 55.00 62.00 66.00 82.00 96.00 105.00 113.00 139.00 192.00 234.00 333.00 405.00 563.00 945.00 Voltage Letter G Catalog No 50 75 100 150 200 250 300 350 500 750 1000 1500 2000 3000 5000 MT0050G MT0075G MT0100G MT0150G MT0200G MT0250G MT0300G MT0350G MT0500G MT0750G MT1000G MT1500G MT2000G MT3000G MT5000G Voltage Letter C List Price $ MT0050B MT0075B MT0100B MT0150B MT0200B MT0250B MT0300B MT0350B MT0500B MT0750B — — — — — 54.00 65.00 71.00 91.00 116.00 136.00 143.00 150.00 188.00 168.00 — — — — — 75.00 80.00 84.00 108.00 140.00 148.00 173.00 182.00 203.00 281.00 332.00 430.00 574.00 718.00 1149.00 Includes A 2-pole Catalog No secondary fuse clip on sizes 50–750VA. primary Class CC fuse kit is available for field installation. See page 16-79 for details. Catalog Number: KCCFPX2R. Discount Schedule NEMA 54.00 65.00 71.00 91.00 116.00 136.00 143.00 150.00 188.00 — — — — — — Voltage Letter I List Price $ MT0050H MT0075H MT0100H MT0150H MT0200H MT0250H MT0300H MT0350H MT0500H MT0750H MT1000H MT1500H MT2000H MT3000H MT5000H List Price $ MT0050C MT0075C MT0100C MT0150C MT0200C MT0250C MT0300C MT0350C MT0500C — — — — — — Voltage Letter H List Price $ Catalog No Voltage Letter D 75.00 80.00 84.00 108.00 140.00 148.00 173.00 — 203.00 281.00 332.00 430.00 574.00 718.00 1149.00 Catalog No MT0050I MT0075I MT0100I MT0150I MT0200I MT0250I MT0300I MT0350I MT0500I MT0750I MT1000I MT1500I MT2000I MT3000I — Catalog No Voltage Letter E List Price $ MT0050D MT0075D MT0100D MT0150D MT0200D MT0250D MT0300D MT0350D MT0500D — — — — — — 54.00 65.00 71.00 91.00 116.00 136.00 143.00 150.00 188.00 — — — — — — Voltage Letter J List Price $ 54.00 65.00 71.00 91.00 116.00 136.00 143.00 150.00 188.00 236.00 332.00 374.00 574.00 718.00 — Catalog No List Price $ MT0050E MT0075E MT0100E MT0150E MT0200E MT0250E MT0300E MT0350E MT0500E MT0750E MT1000E — — — — 75.00 80.00 84.00 108.00 140.00 148.00 173.00 182.00 203.00 — — — — — — Catalog No MT0050L — MT0100L MT0150L — MT0250L — MT0350L MT0500L MT0750L — — — — — A B C D E F G H I J L M Voltage Letter F 54.00 63.00 66.00 79.00 98.00 121.00 143.00 153.00 163.00 186.00 288.00 — — — — Voltage Letter L List Price $ MT0050J MT0075J MT0100J MT0150J MT0200J MT0250J MT0300J MT0350J MT0500J — — — — — — Catalog No Letter Catalog No List Price $ MT0050F MT0075F MT0100F MT0150F MT0200F MT0250F MT0300F MT0350F MT0500F MT0750F — — — — — 54.00 57.00 66.00 79.00 98.00 121.00 143.00 151.00 163.00 172.00 — — — — — Voltage Letter M List Price $ 77.00 — 86.00 113.00 — 153.00 — 188.00 211.00 293.00 — — — — — Catalog No MT0050M MT0075M MT0100M MT0150M MT0200M MT0250M MT0300M MT0350M MT0500M MT0750M — — — — — List Price $ 77.00 82.00 86.00 113.00 145.00 153.00 180.00 188.00 211.00 293.00 — — — — — Includes secondary fuse clip on sizes 50–500VA. Does not include secondary fuse clip on any size. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-77 NEMA & General Purpose Control VA Rating Catalog No Secondary Volts 120/115/110 24 24 24 110/115/120 120 115 95/115 110 X 220 24 X 115, 23 X 110, 25 X 120 99/120/130, 95/115/125, 91/110/120, 85/100/110 120 X 240 CONTROL PRODUCTS Catalog No 50 75 100 150 200 250 300 350 500 750 1000 1500 2000 3000 5000 Voltage Letter B Primary Volts 50/60 Hz 240 X 480, 230 X 460, 220 X 440 240 X 480 120 X 240 115 X 230 550/575/600 208/277 208/230/460 230/460/575 380/400/415 208/230/460, 200/220/440,240/480 240/416/480/600, 230/400/460/575, 220/380/440/550, 208/500 240 X 480 16 VA Rating Voltage Table Industrial Control Power Transformers International, Class MTG Selection Ordering Information 왘 왘 왘 왘 VA Rating Use the Voltage Table to determine the primary and secondary voltage required. Field Modifications see page 16-79. Dimensions see page 16-113. Wiring Diagrams see page 16-147. Voltage Letter A Voltage Letter B Catalog No List Price $ Catalog No MTG0050A MTG0075A MTG0100A MTG0150A MTG0200A MTG0250A MTG0300A MTG0350A MTG0500A MTG0750A MTG1000A MTG1500A MTG2000A MTG3000A MTG5000A 62.00 72.00 82.00 87.00 109.00 125.00 141.00 150.00 186.00 257.00 309.00 424.00 475.00 689.00 1033.00 MTG0050B MTG0075B MTG0100B MTG0150B MTG0200B MTG0250B MTG0300B MTG0350B MTG0500B MTG0750B MTG1000B — — — — Voltage Letter C List Price $ Catalog No 71.00 86.00 97.00 122.00 155.00 183.00 192.00 218.00 252.00 354.00 460.00 — — — — MTG0050C MTG0075C MTG0100C MTG0150C MTG0200C MTG0250C MTG0300C MTG0350C MTG0500C MTG0750C MTG1000C — — — — Primary Volts 50/60 Hz Secondary Volts 240 X 480, 230 X 460, 220 X 440 240 X 480 120 X 240 550/575/600 380/400/415 208/230/460, 200/220/440, 240/480 380 120/115/110 24 24 110/115/120 110 X 220 24 X 115, 23 X 110, 25 X 120 24 Voltage Letter E List Price $ Catalog No 71.00 86.00 97.00 122.00 155.00 183.00 192.00 218.00 252.00 354.00 — — — — — MTG0050E MTG0075E MTG0100E MTG0150E MTG0200E MTG0250E MTG0300E MTG0350E MTG0500E MTG0750E — — — — — Voltage Letter I List Price $ Catalog No 71.00 80.00 87.00 105.00 150.00 187.00 192.00 229.00 252.00 354.00 — — — — — MTG0050I MTG0075I MTG0100I MTG0150I MTG0200I MTG0250I MTG0300I MTG0350I MTG0500I MTG0750I — — — — — Letter A B C E I J P Voltage Letter J Voltage Letter P List Price $ Catalog No List Price $ Catalog No List Price $ 100.00 105.00 110.00 145.00 158.00 200.00 219.00 243.00 272.00 378.00 — — — — — MTG0050J MTG0075J MTG0100J MTG0150J MTG0200J MTG0250J MTG0300J MTG0350J MTG0500J MTG0750J MTG1000J — — — — 72.00 81.00 110.00 153.00 184.00 193.00 247.00 258.00 272.00 517.00 574.00 — — — — MTG0050P MTG0075P MTG0100P MTG0150P MTG0200P MTG0250P MTG0300P MTG0350P MTG0500P MTG0750P — — — — — 71.00 86.00 97.00 122.00 155.00 183.00 192.00 218.00 252.00 354.00 — — — — — NEMA & General Purpose Control CONTROL PRODUCTS 16 50 75 100 150 200 250 300 350 500 750 1000 1500 2000 3000 5000 Voltage Table 16-78 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Field Modification Kits Class SMF, MMS, MRS Selection Accessories—Class SMF Accessories—Class MMS, MRS Description Catalog Number List Price $ Handle Guard Kit with Padlock Provision Emergency Off Actuator Additional Key for Key Operated Devices SMFFL1 SMFPB1 SMFFK1 8.60 22.00 2.90 Pilot Light Kits—Class MMS, MRS Device Class SMF Voltage Rating 115–277V AC SMFFL1 SMFPB1 SMFFK1 Voltage Rating Catalog Number List Price $ Catalog Number List Price $ Device SMFPL10 110–120V AC Class MMS 208–277V AC 440–600V AC 26.00 List Price $ 8.60 22.00 2.90 SMFPL10G 26.00 Red Pilot Light Green Pilot Light Catalog Number List Price $ Catalog Number List Price $ SMFPL11 SMFPL12 SMFPL13 43.00 43.00 43.00 SMFPL11G SMFPL12G SMFPL13G 43.00 43.00 43.00 Enclosures—Class MMS For Use With SMF Standard Size NEMA 1 General Purpose FO1, FO1P, FO2, FO2P, FO3, FO3P, FO4, FO4P Oversized NEMA Type 1 General Purpose FO1, FO1P, FO2, FO2P, FO3, FO3P, FO4, FO4P NEMA 3R, 4, 12 Watertight Dust-tight FO1, FO1P, FO2, FO2P, FO3, FO3P, FO4, FO4P Catalog Number SMFFE2 SMFFE1 SMF40BC1 List Price $ 23.00 26.00 138.00 Nameplates—Class SMF Enclosure Type For Use With MMS Standard Size NEMA 1 General Purpose Oversized NEMA Type 1 General Purpose Jumbo NEMA Type 1 General Purpose NEMA 3R, 4, 12 Watertight Dust-tight KO1, KO1P, KO1B, KO2, KO2A, KO2B, KO3, KO3A, KO3B, KO4, KO4A, KO4B KO1, KO2B, KO2C, KO3, KO3A, KO3B, KO4, KO4B, KO4C, KO2 KO1, KO2B, KO2C, KO3, KO3A, KO3B, KO4, KO4B, KO4C, KO2 KO1, KO2B, KO2C, KO3, KO3A, KO3B, KO4, KO4B, KO4C Catalog Number List Price $ MMSKE3 26.00 MMSKE1 26.00 MMSKE2 51.00 SMF40BC1 138.00 Nameplates—Class MMS List Price $ Catalog Number Without Pilot Light List Price $ SMFFN2 13.00 — — None SMFFSN3 30.50 SMFFSN4 30.50 NEMA 1 None surface mounted enclosure High or gray flush plate Low SMFFN30 SMFFN31 SMFFN32 13.00 13.00 13.00 SMFFN40 SMFFN41 SMFFN42 13.00 13.00 13.00 Standard commercial switch box cover including stainless steel plates NEMA 1 surface mounted enclosure or gray flush plate Nameplate Catalog Marking Number List Price $ Catalog Number List Price $ None SMFFN1 13.00 — — None High Low Forward Reverse SMFFN10 SMFFN11 SMFFN12 SMFFN13 SMFFN14 13.00 13.00 13.00 13.00 13.00 SMFFN20 SMFFN21 SMFFN22 — SMFFN24 13.00 13.00 13.00 — 13.00 Replacement Parts—Class SMF, MMS Description Catalog Number Replacement Toggle Kits:Type FW and KW (NEMA 4 Metallic Enclosure) SMFHW1 List Price $ 26.00 Pilot lights can be field installed on standard NEMA 1 general purpose surface mount enclosures, and NEMA 3R, 4 and 12 enclosures only. For flush mounting units a complete switch unit with pilot light must be ordered. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-79 NEMA & General Purpose Control None For Use On With Pilot Light CONTROL PRODUCTS Nameplate Catalog Marking Number With Pilot Light 16 Without Pilot Light Stainless Steel Plate Handle Guard Kit with Padlock Provision Emergency Off Actuator Additional Key for Key Operated Devices Green Pilot Light Enclosure Type Standard commercial switch box cover including stainless steel plates Catalog Number Pilot Light Kits—Class MMS, MRS Red Pilot Light Enclosures—Class SMF For Use On Description Field Modification Kits Class 11 - 3RV Selection Description Type Catalog Number List Price $ 1 SPDT contact, NO/NC 1 NO ѿ 1 NC 1 SPDT contact NO/NC electronic contact 1 NO ѿ 1 NC 2 NO 2 NC 2 NO ѿ 2 NC 3RV1901-1D 3RV1901-1E 3RV1901-1G 3RV1901-1A 3RV1901-1B 3RV1901-1C 3RV1901-1J 21.50 26.00 80.00 26.00 26.00 26.00 26.00 1NO + 1NC for any trip + 1NO + 1NC for short circuit trip only. 3RV1921-1M 43.00 Auxiliary Contact Blocks 3RV1901-1D 3RV1901-1A CONTROL PRODUCTS 16 3RV1912-1CP0 Plug in contact block 1 block per 3RV mountable at the front Side mount auxiliary contact with screw connection 1 side mount auxiliary contact per 3RV mountable on the left-hand side Signaling Contact Block Signaling contact 1 signaling contact per 3RV mountable on the left-hand side. Can also be fitted together with side mount auxiliary contact. Auxiliary Releases Undervoltage release 1 undervoltage release per 3RV mountable on the right-hand side. Cannot be fitted together with shunt trip. Undervoltage release with early make contacts (2NO) 1 undervoltage release per 3RV mountable at the right-hand side. Cannot be fitted together with shunt trip. Shunt trip 1 shunt trip per 3RV mountable at the righthand side. Cannot be fitted together with undervoltage release. Pilot Lights For NEMA 1 enclosure only. Kit includes Red, Green, and Amber lenses 3RV1902-1DP0 AC 60Hz 120V 208V 240V 480V 3RV1902-1AF0 3RV1902-1AM1 3RV1902-1AP0 3RV1902-1AV1 66.00 66.00 66.00 66.00 AC 50Hz 230V 415V AC 60Hz 240V 480V 3RV1922-1CP0 3RV1922-1CV1 83.00 83.00 AC 50Hz/60Hz 20–24V 90–110V 200–240V 350–415V DC 20–70V 70–190V 190–330V 330–500V 3RV1902-1DB0 3RV1902-1DF0 3RV1902-1DP0 3RV1902-1DV0 66.00 66.00 66.00 66.00 AC 50Hz/60Hz 130.00 130.00 130.00 130.00 130.00 24V 120V 240V 480V 600V 49SBLBJ 49SBLBF 49SBLBG 49SBLBH 49SBLBE For 3RV with amp range: 0.11-22A up to 480V Max. 0.11-12.5A up to 575V Max 3RV1928-1H 16.00 Four mounting holes required for each 3RV. 3RB1900-0B 1.10 For sealing the FLA adjustment dial (Kit includes 10 covers) 3RV1908-0P 2.10 For sealing the front mount auxiliary opening. (Kit includes 10 covers) 3RV1901-0H 53.00 130 mm depth 3RV1926-0B 104.00 330 mm depth with supporting bracket 3RV1926-0K 124.00 Lug Kit Required for Type E Manual Combination Starter NEMA & General Purpose Control AC 50Hz — 230V 415V Mounting Push-in Mounting Hole Kit For screw panel mounting of the 3RV Sealing device 3RV1928-1H Adjustment Dial covers Front mount auxiliary cover Door Operators 3RV1901-0H 100% on time. 5 sec. max. on time. Discount Code: PILO. 16-80 Thru-the-door operators Rotary operating mechanism, rated NEMA 12, lockable with up to 3 padlocks in the OFF position. Includes extension shift and connecting element for the 3RV. With Black Handle Compatible for use in dusty atmospheres. Contacts rated for 1-300mA @ 3-60V. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule IEC Field Modification Kits Pilot Devices Push Buttons and Selector Switches Selection Class Enclosure Type Controller Size or (Lighting Rating) Open 00-4 00-4 or (20–100A) 49SBPB5 14, 40, LEN, CLM 1 5-8 or (200–400A) 49SBSB1 22, 43 30 (2S1W) 00-8 or (20–400A) Open 00-4 00-4 1 5-8 12, 4/4X 0-8 Open 0-4 0-1 3⁄4 1 2-4 Open 1 0-4 0-4 12, 4/4X 0-4 17, 18, 36, 37, 83, 84, LED,LEF, LEB, CMN , CMF , CMB 1, 12, 4/4X 0-8 (20-400A) 25, 26 1, 12, 4/4X 0-8 32 1, 12, 4/4X 0-4 30 (2S2W) Start, Stop Push Buttons Hand-Off-Auto Selector Switch Off-On Selector Switch Start, Stop Push Buttons Hand-Off-Auto Selector Switch Off-On Selector Switch Start, Stop Push Buttons Hand-Off-Auto Selector Switch Keyed Hand-Off-Auto (key removable in all positions) Off-On Selector Switch Start, Stop Push Buttons Hand-Off-Auto Selector Switch Keyed Hand-Off-Auto (key removable in all positions) Off-On Selector Switch Forward-Off-Reverse Selector Switch Forward-Off-Reverse Selector Switch Forward, Reverse, Stop Push Buttons Forward-Off-Reverse Selector Switch Forward, Reverse, Stop Push Buttons Forward-Off-Reverse Selector Switch High-Off-Low Selector Switch High-Off-Low Selector Switch High, Low, Stop Push Buttons High-Off-Low Selector Switch High, Low, Stop Push Buttons High-Off-Low Selector Switch High-Off-Low Selector Switch High-Off-Low Selector Switch High, Low, Stop Push Buttons High-Off-Low Selector Switch Start, Stop Push Buttons Hand-Off-Auto Selector Switch Keyed Hand-Off-Auto (key removable in all positions) Off-On Selector Switch Forward, Reverse, Stop Push Buttons Forward-Off-Reverse Selector Switch High, Low, Stop Push Buttons High-Off-Low Selector Switch 49SAPB5 49SASB1 49SASB4 49SBPB5 49SBSB1 49SBSB4 49SAP05 49SAS01 49SAS09 49SAS04 49SAP05 49SAS01 49SAS09 49SAS04 49SASB2 49SBSB2 49SAP02 49SAS02 49SAP02 49SAS02 49SASB3 49SBSB3 49SAP03 49SAS03 49SAP03 49SAS03 49SASB3 49SBSB3 49SAP03 49SAS03 49SAP05 49SAS01 49SAS09 49SAS04 49SAP02 49SAS02 49SAP03 49SAS03 List Price $ 69.00 69.00 69.00 69.00 69.00 69.00 69.00 69.00 133.00 69.00 69.00 69.00 133.00 69.00 69.00 69.00 130.00 69.00 130.00 69.00 69.00 69.00 130.00 69.00 130.00 69.00 69.00 69.00 130.00 69.00 69.00 69.00 133.00 69.00 130.00 69.00 130.00 69.00 CONTROL PRODUCTS 0-4 Catalog Number 16 12, 4/4X 49SAP05 49SAS01 12, 4/4X Type NEMA & General Purpose Control To be used for replacement of switch only. Does not include relay or extra contact block on 30-400A CLM and CM Lighting Contactors. Class 49SB not available for these devices. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-81 Field Modification Kits NEMA, Lighting and Heating Contactors, 20 Amp CLM, CMB, CMF, CMN Selection Solid State Control Module Kits For Lighting and Heating Contactors CLM 20 Amp Contactor Kit Description 120V AC, 50/60 Hz 24V AC/DC, 50/60 Hz 240/277V AC, 50/60 Hz 12V AC/DC, 50/60 Hz Accessory 47 (2-Wire Control) (2W) Catalog Number List Price $ CLM4379771 415.00 CLM4379772 415.00 CLM4379773 415.00 CLM4379774 415.00 Accessory 48 (3-Wire Control) (3W) Catalog Number List Price $ CLM4379781 454.00 CLM4379782 454.00 CLM4379783 454.00 CLM4379784 454.00 Accessory 49 (Start/Stop Control) (3WS) Catalog Number List Price $ CLM4379791 484.00 CLM4379792 484.00 CLM4379793 484.00 CLM4379794 484.00 Protective Shielding for NEMA Products ! CONTROL PRODUCTS 16 NEW Class 14 Class 40 Class 14, 22, 30, 40, 43 Contactor or Starter Size 00–13⁄4 Contactor Shield Catalog Number Starter Shield Catalog Number NEMA & General Purpose Control Disconnect with protective shield List Price $ 2–21⁄2 List Price $ 3–31⁄2 List Price $ 4 List Price $ 49PSC1 45.00 49PSC2 52.00 49PSC3 62.00 49PSC4 76.00 49PSS1 52.00 49PSS2 59.00 49PSS3 78.00 49PSS4 83.00 Class 17, 25, 32, 87 Disconnect Size Catalog Number 30A 60 & 100A 200A 49PSD5 49PSD6 49PSD7 List Price $ 74.00 79.00 84.00 These kits are only for use with 20A mechanically held lighting contactors. 16-82 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Field Modification Kits Pilot Lights Description Selection Enclosure Type Class 1 Controller Size or (Lighting Rating) 00–4 or (20–200A) Voltage Catalog Number Red, Green, Amber ON, RUN, OFF , OL TRIPPED , FORWARD, REVERSE, LOW, HIGH Red (Transformer Type) ON Green (Transformer Type) OFF Red, Green, Amber ON, RUN, OFF , OL TRIPPED , FORWARD, REVERSE, LOW, HIGH Red (Transformer Type) ON Green (Transformer Type) OFF Red (Transformer Type) ON Green (Transformer Type) OFF 24 Vac 120 Vac 208/240/277 Vac 480 Vac 600 Vac 24 Vac (Full Voltage) 120 Vac 240 Vac 480 Vac 600 Vac 24 Vac (Full Voltage) 120 Vac 240 Vac 480 Vac 600 Vac 24 Vac 120 Vac 208/240/277 Vac 480 Vac 600 Vac 24 Vac (Full Voltage) 120 Vac 240 Vac 480 Vac 600 Vac 24 Vac (Full Voltage) 120 Vac 240 Vac 480 Vac 600 Vac 24 Vac (Full Voltage) 120 Vac 240 Vac 480 Vac 600 Vac 24 Vac (Full Voltage) 120 Vac 240 Vac 480 Vac 600 Vac 49SBLBJ 49SBLBF 49SBLBG 49SBLBH 49SBLBE 49SPL0BRJ 49SPL0BRF 49SPL0BRG 49SPL0BRH 49SPL0BRE 49SPL0AGJ 49SPL0AGF 49SPL0AGG 49SPL0AGH 49SPL0AGE 49SBLBJ 49SBLBF 49SBLBG 49SBLBH 49SBLBE 49SPL0BRJ 49SPL0BRF 49SPL0BRG 49SPL0BRH 49SPL0BRE 49SPL0AGJ 49SPL0AGF 49SPL0AGG 49SPL0AGH 49SPL0AGE 49SPL0BRJ 49SPL0BRF 49SPL0BRG 49SPL0BRH 49SPL0BRE 49SPL0AGJ 49SPL0AGF 49SPL0AGG 49SPL0AGH 49SPL0AGE Red, Green, Amber — — 49SBLBL 14, 40, 22 , 43 , 30 (2S2W) , LEN, CLM 1 5–8 or (300–400A) 12, 4/4X 0–8 or (20–400A) 49SBLBF 1 0–4 30 (2S1W) 1 2–4 12, 4/4X 0–4 49SPL0BRF 17, 18, 25, 26 , 32 , 36, 37, 83, 84, 87, 88, LED, LEF, LEB, CMN, CMF, CMB Lens Kit ONLY (30 (2S1W)) 1 (14, 40, 22, 43, 30 (2S2W), LEN, CLM) ”Off” PL requires: (1) N.C. aux contact, 49AB01 on sizes 00-4. Class 22, 25, 26, 30, 32, 43, 83 & 84 requires qty. of (2) pilot light kits. Does not apply to 49SB kits. Select Discount Schedule NEMA 0–6 (20–400A) 0–1 3⁄4 00–4 or (20–200A) 130.00 130.00 130.00 130.00 130.00 130.00 130.00 130.00 130.00 130.00 182.00 182.00 182.00 182.00 182.00 130.00 130.00 130.00 130.00 130.00 130.00 130.00 130.00 130.00 130.00 182.00 182.00 182.00 182.00 182.00 130.00 130.00 130.00 130.00 130.00 182.00 182.00 182.00 182.00 182.00 11.20 NEMA & General Purpose Control 49SBLBL 1, 12, 4/4X List Price $ CONTROL PRODUCTS Legend(s) 16 Lens Color(s) appropriate legend plate as a separate item per type of starter; either “FORWARD” & “REVERSE” or “LOW” & “HIGH”. 2S2W is starter size 0–4. Includes NC aux contact for NEMA starter Size 0–4. “OL TRIPPED” requires (1) N.O. OL aux 49ASNO for ESP 100 OL relay. Use suffix “91” for amb. comp. OL size 00-21⁄2. Not available sizes 3-4. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-83 Field Modification Kits NEMA, Reduced Voltage and Lighting Selection Starter/Contactor Auxiliary Contact Kits Description Class Size 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88 00-4 14, 17, 18, 22, 25, 26, 36, 37, 40, 43, 87, 88 5, 6 14, 17, 18, 22, 25, 26 40, 43 7, 8 20-60 Amps LEN, LED, LEF, LEB 100 Amps 200-400 Amps 20 Amps 30-200 Amps NEMA & General Purpose Control CONTROL PRODUCTS 16 CLM, CMN, CMF, CMB 300-400 Amps Type 1 NO 1 NC 1 NC Early Break 1 NC Late Break 1 NC Extra Late Break 1 NO Extra Late Make 1 NO & 1 NC 2 NO 4 NO 3 NO & 1 NC 2 NO & 2 NC 2 NO 1 NO & 1 NC 2 NC Catalog Number 49AB10 49AB01 49AB01EB 49AB01LB 49AB01XLB 49AB10XLM 49AB11 49AB20 49AB40 49AB31 49AB22 3RH1921-1EA20 3RH1921-1DA11 3RH1921-1EA02 List Price $ 1 NO & 1 NC (Inside L or R) 49CAL18-11 34.00 34.00 51.00 51.00 51.00 51.00 51.00 51.00 103.00 103.00 206.00 206.00 206.00 21.50 21.50 21.50 1 NO & 1 NC (Outside L or R) 49CAL18-11B 1 NO 1 NC 2 NO 1 NO & 1 NC 2 NC 1 NO 1 NC 1 NO/NC SPDT 1 NO/NC SPDT 1 NO/NC SPDT 2 NO/NC SPDT 1 NO & 1 NC 2 NC 2 NO 1 Coil Clearing NO & NC 1 NO & 1 NC 2 NC 2 NO 1 Coil Clearing NO & NC 49ACR0 49ACRC 49ACR7 49ACR6 49ACR8 49D22125001 49D22125002 49CE42SPDT 3RH1921-1DA11 CLM4097291 CLM4097292 CLMFCAK11 CLMFCAK02 CLMFCAK20 CLMFCCK11 CLMHCAK11 CLMHCAK02 CLMHCAK20 CLMHCCK11 Type Catalog Number 2 NO/2 NC DPDT (NEMA A600) HA261234 266.00 1 NO/1 NC 240V 1 NO/1 NC 480V (2) 1 NO/1 NC SPDT-480V A02ED62 A02FD64 A02JLD64 540.00 540.00 540.00 14.30 14.30 28.50 28.50 28.50 51.00 51.00 51.00 21.50 97.00 193.00 71.00 71.00 71.00 71.00 71.00 71.00 71.00 71.00 Disconnect Auxiliary Switch Kits Disconnect Amp or CB Rating Description Class Non-fusible or Fusible Type 17, 25, 32, 37, 83, 84, 30 - 200A 87, 88, LED, LEF, CMN, CMF MCP 18, 26, 32, 37, 83, 84, 87, 88, LEB, CMB 3A–125A 250A 400A-600A List Price $ Control Power Transformer Kits Description Recommended Transformer Size Control Size Transformer VA VA Rating Catalog Number List Price $ 0–21⁄2 3–31⁄2 4 5-6 7-8 45 VA 50 VA 100 VA 150 VA 200 VA 300 VA 500 VA KT*050 KT*050P KT*100 KT*150 KT*200 KT*300 KT*500 155.00 207.00 216.00 289.00 323.00 398.00 475.00 45 or 50 75 100 150 300 Lighting Control Transformer 50/60HZ 45VA CLM 20A, 2 - 12P 30A, 3P 30A, 6 - 12P 60A, 3P 60A, 4 - 6P 60A, 8 - 12P 100/200A, 3P 100/200A, 5P 300/400A, 3P LEN 20A, 3 - 12P 30/60A, 3 - 6P 30/60A, 9 - 12P 100/200A, 3P 300/400A, 3P 150 100 200 100 150 250 200 250 250 120 208 208 240/480 240/480 277 277 600 600 24 24 120 24 120 24 120 24 120 1 G H 4 8 5 7 6 9 25 25 50 75 150 transformer kits will include secondary but not primary fusing. Sizes 50VA and higher include 16-84 Replace * with code from Transformer table. Kits used with NEMA 1 general purpose lift-off cover type require extra wide enclosure. Class 14 Sizes 0-21⁄2 Class 30 (2S2W) Sizes 0-21⁄2 Class 30 (2S1W) Sizes 0-13⁄4 Transformer Table Primary Volts Secondary Volts Code 2-pole primary fusing and 1-pole secondary fusing. Code: IEC. Discount Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Code: MCCB. Discount Schedule NEMA Field Modification Kits NEMA, Reduced Voltage and Lighting Selection Miscellaneous Kits Class Enclosure Type Controller Size Catalog Number List Price $ Single Reset (Red) 14, 22, 30 4/4X 00–4 49MARSR 28.50 Single Reset (Blue) 14, 22, 30, 17, 18, 25, 26, 32 1, 12, 4/4X 00–4 49MBRS 25.00 1, 12 — 49MARB 17.90 — — 49ASRE 14.60 Description Overload Resets Miniature Universal Reset ESP100 Reset Extender 49MBRS For use in any manufacturer’s 36, 37 enclosure — 8 inches For use with Siemens MCC’s and — other deep enclosures. Attaches to OL devices Oil Tight Boot For Single and Multi Unit using 49MARSR Resets — 4, 4X — 52AABA 16.40 Starter Mounting Adapter Plate Fits Allen Bradley 509 and 709, Westinghouse A200 14 Open 00–1 49D70084 14.60 ESP100 Mounting Plate ESP100 Mounting Plate Kit 48 Open 00–13⁄4 2–21⁄2 3–4 49ASMP1 49ASMP2 49ASMP3 14.30 14.30 14.30 49ASRFTC 14.60 Furnas Brand Thermal Overload A, A1 Frame Size Retrofit Kit, Sizes 0–13⁄4 Overload Lug Extender Overload Tamper Resistant Cover Replacement Dial Cover Discount Schedule NEMA 0–1 (9–40A Ranges) 49ASLE 23.00 All All 0–4 (9–135A Ranges) 49ASTC (Bag of 10) 29.50 1 Fuse All All 49MAFB1 17.90 2 Fuses All All 49MAFB2 26.00 2 Fuses All All 49MAFB4 26.00 All All 00–4 49ASDS (Bag of 10) 29.50 For ESP100 overload without pass through windows All All 00–1 (0.25–10A) 49ASDL (Bag of 10) 29.50 For ESP100 overload without pass through windows 48AS, 48CS All 00–1 (0.25–10A) 49ASMS 14.60 For 13⁄32 11⁄2 Fuses For Rejection-Type Fuses For ESP100 overload Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEMA & General Purpose Control Replacement Separate Mounting Kit (Included with standard 48AS and 48CS overloads) All CONTROL PRODUCTS Dust Seal All 16 Fuse Block 30A Max Suitable for Class CC fuses Includes terminal block and stabs for connection to contactor terminals to provide connections at bottom of ESP100 overload Can be closed with wire seal to deter tampering of ESP100 overload FLA adjustment dial (Clear cover) 16-85 Field Modification Kits NEMA, Reduced Voltage and Lighting Selection Miscellaneous Kits Description Enclosure Type Class Mechanical Interlock for Horizontally Mounted Contactors 14, 40 Open Mechanical Interlock 14, 40 Open Includes wire & mounting plate 14, 40 Open 14, 40 Open All but Class LE, CLM All 00–31⁄2 All but Class LE, CLM All 00–13⁄4 LEN, LED, LEF, LEB All 20 Amps CLM All 20 Amps LEN, CLM Open All but Class LE, CLM Base Plate Only Includes mounting plate (Different Frame Sizes) Surge Suppressor for 120V AC coil. Limits transient voltage produced by the coil to 220% maximum peak line volts. NO 36A at 600V AC Max NC 25A at 600V AC Max 2 NC (mounts to contactor or power pole) 2 NO (mounts to contactor or power pole) 2 NO (mounts to contactor only) 1 NO (mounts to contactor only) Top or Bottom, 2-Pole Main Contacts Top, 3-Pole Lighting Contactors Top or Bottom, 4-Pole Top or Bottom, 6-Pole CONTROL PRODUCTS 16 Auxiliary Power Pole Load Side Power Take Off Kit Mounting Kit for Open Heating & Lighting 6 - 12-poles Includes 3 power lugs for making extra connections to the load side of the contactor For AL/CU Wire NEMA & General Purpose Control Lug Kit for Contactors Item Wire Range 49SAAF 2-14 49SAAH 2/0-14 For AL/CU Wire 75D35994001 250MCM-6 Ground Lug Kit Meets CSA Standard 22.2 No 14-1973 Right 3, 3 1⁄2 2, 2 1⁄2 61.00 61.00 61.00 77.00 116.00 43.00 357.00 463.00 187.00 213.00 168.00 1342.00 69.00 69.00 69.00 96.00 143.00 49L107944 49L107945 99.00 99.00 49D26344 35.00 49SAF0 49SAFC 96.00 96.00 49LN02A 49LN20A 49LS20A 49LS10A CLM4097331 CLM4097332 CLM4097333 CLM4097334 101.00 101.00 101.00 101.00 258.00 290.00 355.00 419.00 30, 60 Amp 49MCMPMA 24.00 All 00–13⁄4 49SAE 30.50 14, 40 All 2-21⁄2 3-31⁄2 4 49SAAF 49SAAH 75D35994001 43.00 51.00 89.00 14, 40 All 5, 6 3RT1966-4G 158.00 252.00 626.00 Use CU Only 14, 40 All 7 8 49ATK750-3 49ATK1650-6 1 Conductor 2-14 For AL/CU Wire All All All 49D11960001 8.90 276.00 Lightning Arrestor Illustration Catalog Number List Price $ 49CCF22H 49EEF22H 49GGF22H 49HHP22H 49JJG22H 3RT1954-2A 3RA1963-2A 3RA1973-2A 3RA1962-2A 3RA1972-2A 49VM750H 49VM1650H 49CCF22HP 49EEF22HP 49GGF22HP 49HHP22HP 49JJG22HP Open Wire Kit Only Auxiliary Power Pole 00–1 1 3⁄4 2, 2 1⁄2 3, 3 1⁄2 4 5, 6 5 6 5 6 7 8 00–1 1 3⁄4 2, 2 1⁄2 3, 3 1⁄2 4 Left 2, 2 1⁄2 3, 3 1⁄2 14, 40 Includes wire Interlock Only Surge Suppressor Controller Size All All All 49D45584002 Backspin Timer On delay timer that reduces risk of starting into a backspin 87, 88 All All 3RP20 25-1AQ30 3RP20 25-1AP30 64.00 64.00 Hole Plug Covers the hole that is typically used for the conduit hub 87 All 1-4 49D41149006 23.00 Description Contactor Wire Size Catalog Number List Price $ Lug Kit 1 Kit = 1 Terminal block. 1 kit necessary for each line and load. NEMA size 4 (Vacuum) NEMA size 5 NEMA size 6 2/0 to 600 MCM, max. one 500MCM & one 600MCM 3RT1966-4G 158.00 3RT1966-4G Discount Code: IEC. Surge Suppression for NEMA sizes 5 – 8 are supplied internal with the coil. For size 4 panel mount. 16-86 Only 3 lugs are suplied for line or load. If lugs for line and load are required order 2 kits. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Lug Kit for contactors include 3 terminals for line or load. Discount Schedule NEMA Field Modification Kits NEMA, Reduced Voltage and Lighting Selection Fused and Non-Fused Disconnect Switch Kits (Includes load base plus line and load fuse Basic Switch Ampere Rating Switch Catalog Number Non-Fused List Price $ 30 HNB612 77.00 60 HNB623 313.00 100 HNB623 200 HNB64 Switch Catalog Number Fused List Price $ 313.00 HFB21 HFB612 HFB22 HFB62 HFB63 84.00 137.00 141.00 169.00 208.00 327.00 HFB64 447.00 Kit Description Load Base Catalog Number Class J 30A, 250V 30A, 600V 60A, 250V 60A, 600V 100A, 250V 100A, 600V 200A, 250V 200A, 600V — HBB612 — HBB62 — HBB63 — HBB64 List Price $ — 81.00 — 97.00 — 176.00 — 256.00 clips) Load Base Catalog Number Class H List Price $ Lug Wire Size HBB21 HBB612 HBB22 HBB62 HBB63 56.00 81.00 83.00 97.00 176.00 #14-2 AWG (Cu/AI) HBB64 256.00 #6-300 AWG (Cu/AI) #14-2 AWG (Cu/AI) #14-1/0 AWG (Cu/AI) Class R Fuse Conversion Kits Catalog Number Description List Price $ HR21 HR612 HR612 HR62 HR63 HR64 30A, 240V 30A, 600V 60A, 240V 60A, 600V 100A, 240/600V 200A, 240/600V 83.00 83.00 83.00 83.00 54.00 54.00 Hazardous Location Accessories For Enclosure Types 7 & 9 Description Conduit Size Inches Install in bottom as drain. Install in top as breather. Suitable for Class I groups C & D and for Class II groups F & G applications only. for 1⁄2" NPT. Breather/Drain 51AAHA 51AAHB 51AAHC 51AAHD 51AAHE 51AAHF 4.20 4.60 5.10 8.20 13.80 21.00 For tapered NPT conduit openings. 3 ⁄4–1⁄2 1–1⁄2 11⁄2–3⁄4 11⁄2–1 51AARBA 51AARCA 51AARDB 51AARDC 4.20 4.60 10.20 10.20 Cast aluminum, UL Recognized and CSA Certified. Used to reduce existing tapered NPT conduit opening when required. 2 1⁄2–3⁄4 2 1⁄2–1 2 1⁄2–11⁄2 2 1⁄2–2 51AARFB 51AARFC 51AARFD 51AARFE 31.00 29.50 25.50 25.50 Reducer Bushings 3–1 3–11⁄2 3–2 3–21⁄2 51AARGC 51AARGD 51AARGE 51AARGF 41.50 41.50 32.50 32.50 Enclosure Type Catalog Number List Price $ 49MACML 49MACMD 49MACMN 49MACMF 49MACMG 19.00 21.00 26.00 33.00 72.00 75D41149001 75D41149003 75D41149004 75D41149005 19.00 19.00 19.00 19.00 Conduit Hubs Conduit Size Description Conduit Hubs For Enclosures Noncombination - NEMA 12 may be field modified for NEMA 3/3R. Combination - NEMA 12 may be field modified for NEMA 3/3R/4 enclosure. Use UL Listed conduit hub for the appropriate NEMA type. NEMA 3R requires the location of the conduit hub to be at a level above the lowest live part and holes of 1/8" dia. to be added in the bottom of the enclosure. Does not apply to class 87 Pump Panels. Discount Discount Code: PILO. code: HDSS. Discount Schedule NEMA Metal Hub Metal Hub 3 ⁄4" 1" 1 1⁄2" 2" 2 1⁄2" 1" 1 1⁄2" 2" 2 1⁄2" Class Controller Size All All 12, 3, 3R, 4 87 All 3R For Class R fuses order Class H kit from this table and the Class R conversion kit. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-87 NEMA & General Purpose Control ⁄2 ⁄4 1 11⁄2 2 21⁄2 3 CONTROL PRODUCTS 41.00 16 51AADB 1 Hole Plugs Catalog Number List Price $ Field Modification Kits NEMA, Overload Relays Selection Sirius 3RB20 Illustration Description For Overload Type Catalog Number List Price $ 3RB206 3RU1900-1A 12.80 3RU1900-1B 59.00 3RU1900-1C 64.00 3RB2984-0 6.00 Reset mechanisms Reset plunger Mounts directly to overload relay. Requires separate reset operator in enclosure door. Kit includes reset plunger, holder and funnel. Reset plunger with reset button Cable length 15.75 in (400mm) Flexible cable reset mechanism Requires a 6.5 mm hole in the enclosure with a maximum enclosure thickness of 8 mm. 3RB206 Cable length 23.62 in (600mm) Covers Tamper resistant cover for current setting and manual/ automatic reset button. Flexible reset 3RB206 Competitive Retrofit Overload Plates Manufacturer NEMA Size Plate Part Number List Price $ A-B A-B Sq. D 0, 1 2 0, 1 49D57090 49D57161 49D57091 15.60 15.60 15.60 Electronic Coil System with Remaining Lifetime Indication and 24VDC PLC Output Size 5 All 6 Model Type 21 - 27V Catalog Number P V P V – – – – 96 - 127V Catalog Number List Price $ List Price $ 3RT1965-5PF31 3RT1966-5PF31 3RT1975-5PF31 3RT1976-5PF31 – – – – 575.00 660.00 937.00 958.00 200 - 277V Catalog Number List Price $ 3RT1965-5PP31 3RT1966-5PP31 3RT1975-5PP31 3RT1976-5PP31 575.00 660.00 937.00 958.00 Overload Auxiliary Contact Kit Description Class Size All ESP100 00–4 Type Catalog Number List Price $ 1 NO (NEMA A600) 49ASN0 35.00 1 NC (NEMA A600) 49ASNC 35.00 NEMA & General Purpose Control CONTROL PRODUCTS 16 Class Discount 16-88 Code: IEC. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Field Modification Kits Class MT, MTG Selection Fuse Blocks, Touch-Safe Terminal Covers Catalog Number International Fusing Description List Price $ 2-Pole Primary Class CC Fuse Block for domestic fusing. Max 600V.(Single- ole cover kits, if required are listed below. One cover kit required per pole.) Catalog Number 32.00 Description List Price $ 1-Pole Fuse Block, Touch-Safe. Up to 6.3A for 5 mm ҂ 20 mm or 5 mm ҂ 25 mm (Requires DIN Rail Mounting) 7.80 1-Pole Fuse Block, Touch-Safe 25A, for 10 ҂ 38 mm Cylindrical Fuses. (Requires DIN Rail Mounting.) 12.00 2-Pole Fuse Block, Touch-Safe 25A, for 10 ҂ 38 mm Cylindrical Fuses. (Requires DIN Rail Mounting.) 27.00 1-Pole Fuse Block, Touch-Safe 4-50A, for 14 ҂ 51 mm Cylindrical Fuses. (Requires DIN Rail Mounting.) 29.00 Fuse Block DIN Rail Mounting for separate screw mounting to panel. (Max 2-pole 2-25A size per rail.) (Max 1-pole 4-50A size per rail.) 3.80 8WA1011-1SF12 KCCFP2RG 1-Pole Secondary Midget Fuse Block for 13/32 ҂ 11⁄2 domestic Fusing. Max 250V. (Single pole cover kits, if required are listed below.) 11.60 3NW7011 13.00 CONTROL PRODUCTS 3NW7021 KCCFBCK 3NW7111 Snap-On Transformer Terminal Touch-Safe Cover Kit. (Includes primary and secondary covers.) KTTSC4P Discount 11.60 8WA1815 Code: IEC. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-89 NEMA & General Purpose Control Single Pole Fuse Block cover Kit for domestic fuse blocks listed above. (For primary or secondary) 2-Kits required for 2-pole fuse block. 16 KCCF1G Heavy Duty Control Non-Combination Enclosure Kits, Class 49 49 Class 49 — Field Kit E B 14 E Selection B 11 07 05 Reset Installation Starter Size E — 00, 0, 1, 13⁄4 G — 2, 21⁄2 I — 3, 31⁄2 J—4 Type E — Enclosure Only Model B — Model C — 2002 Depth (In Inches) R — Reset Width (In Inches) NEMA Type B — NEMA 1 0 — NEMA 12 W — NEMA 4 S.S. Product Class 14 — Class 14, 40 22 — Class 22, 43 30 — Class 30 R Height (In Inches) Non-Reversing Starters & Contactors Class 14, 40 General Purpose (Clamshell) NEMA 4/4X Stainless Watertight, Dust-tight, Corrosion Resistant NEMA 12/3/3R Without CPT With CPT (Extra Wide) Without CPT With CPT (Extra Wide) Without CPT Model C Enclosure Model C Enclosure Model B Enclosure Model B Enclosure NEMA 1 Size Catalog Number List Price $ Catalog Number 00–13⁄4 2, 21⁄2 3, 31⁄2 3, 31⁄2 4 49EC14EB110705R 49EC14GB140807R 49EC14IB201208R — 49EC14JB251409R 61.00 130.00 235.00 — 361.00 49EC14IB201208R 49EC14IB201208R 49EC14IB201208R 49EC14JB251409R 49EC14JB251409R Model B Enclosure Max CPT List VA Price $ Catalog Number 200 200 100 250 300 235.00 235.00 235.00 361.00 361.00 List Price $ 49EB14EW130806R 414.00 49EB14GW160907R 879.00 49EB14JW261408R 1861.00 — — 49EB14JW261408R 1861.00 Catalog Number Industrial Use, Weatherproof Max CPT List VA Price $ 49EB22EW131306R 49EB22GW161406R 49EB14JW261408R — 49EB22JW302410R 689.00 1301.00 1861.00 — 2791.00 With CPT (Extra Wide) Model B Enclosure Catalog Number List Price $ Catalog Number 49EB14E0130806R 49EB14G0160907R 49EB14J0261408R — 49EB14J0261408R 224.00 354.00 1102.00 — 1102.00 Max CPT List VA Price $ 49EB22E0131306R 49EB22G0161406R 49EB14J0261408R — 49EB22J0302410R 293.00 603.00 1102.00 — 1326.00 Reversing Starters & Reversing Contactors Class 22, 43 General Purpose (Clamshell) NEMA 4/4X Stainless Watertight, Dust-tight, Corrosion Resistant NEMA 12/3/3R Without CPT With CPT (Extra Wide) Without CPT With CPT (Extra Wide) Without CPT Model C Enclosure Model C Enclosure Model B Enclosure Model B Enclosure CONTROL PRODUCTS 16 NEMA 1 Size Catalog Number List Price $ Catalog Number 00–13⁄4 2, 21⁄2 3, 31⁄2 4 49EC14IB201208R 49EC14IB201208R 49EC14JB251409R 49EC14JB251409R 235.00 235.00 361.00 361.00 49EC14IB201208R 49EC14IB201208R 49EC14JB251409R 49EC14JB251409R Model B Enclosure Max CPT List VA Price $ Catalog Number 200 200 250 300 235.00 235.00 361.00 361.00 List Price $ 49EB22EW131306R 689.00 49EB22GW161406R 1301.00 49EB22IW261808R 2791.00 49EB22JW302410R 2791.00 Catalog Number Industrial Use, Weatherproof Max CPT List VA Price $ 49EB22EW131306R 49EB22GW161406R 49EB22JW302410R 49EB22JW302410R 689.00 1301.00 2791.00 2791.00 Catalog Number With CPT (Extra Wide) Model B Enclosure List Price $ Catalog Number 49EB22E0131306R 293.00 49EB22G0161406R 603.00 49EB22I0261808R 1326.00 49EB22J0302410R 1326.00 Max CPT List VA Price $ 49EB22E0131306R 49EB22G0161406R 49EB22J0302410R 49EB22J0302410R 293.00 603.00 1326.00 1326.00 Two-Speed Two-Winding Starters Class 30 NEMA & General Purpose Control NEMA 1 Without CPT With CPT (Extra Wide) Model C Enclosure Model C Enclosure Size Catalog Number List Price $ Catalog Number 00–13⁄4 2, 21⁄2 3, 31⁄2 4 49EC14IB201208R 49EC14IB201208R 49EC14JB251409R 49EC14JB251409R 235.00 235.00 361.00 361.00 49EC14JB251409R 49EC14JB251409R 49EB22JB302410R 49EB22JB302410R NEMA 4/4X Stainless Watertight, Dust-tight, Corrosion Resistant NEMA 12/3/3R Without CPT With CPT (Extra Wide) Without CPT Model B Enclosure Model B Enclosure Model B Enclosure Max CPT List VA Price $ Catalog Number 200 200 300 300 361.00 361.00 422.00 422.00 List Price $ 49EB30EW131306R 689.00 49EB30GW161406R 1301.00 49EB30IW261808R 2791.00 49EB22JW302410R 2791.00 Catalog Number Industrial Use, Weatherproof Max CPT List VA Price $ 49EB30GW161808R 49EB30GW161808R 49EB22JW302410R 49EB22JW302410R 1301.00 1301.00 2791.00 2791.00 With CPT (Extra Wide) Model B Enclosure Catalog Number List Price $ Catalog Number 49EB30E0131306R 49EB30G0161406R 49EB30I0261808R 49EB22J0302410R 293.00 603.00 1326.00 1326.00 Max CPT List VA Price $ 49EB30G0161808R 49EB30G0161808R 49EB22J0302410R 49EB22J0302410R 603.00 603.00 1326.00 1326.00 Two-Speed One-Winding Starters Class 30 General Purpose (Clamshell) NEMA 4/4X Stainless Watertight, Dust-tight, Corrosion Resistant NEMA 12/3/3R Without CPT With CPT (Extra Wide) Without CPT With CPT (Extra Wide) Without CPT Model C Enclosure Model C Enclosure Model B Enclosure Model B Enclosure NEMA 1 Size Catalog Number List Price $ Catalog Number 00–13⁄4 2, 21⁄2 3, 31⁄2 4 49EC14IB201208R 49EB30GB161808R 49EB30IB192208R 49EB22JB302410R 235.00 422.00 448.00 422.00 49EC14JB251409R 49EB22JB302410R 49EB22JB302410R 49EB22JB302410R Model B Enclosure Max CPT List VA Price $ Catalog Number 200 300 300 300 Note: Dimensions...See appropriate Product Class Outline Drawing beginning on page 16-115. For conduit hubs and conversion instructions, see page 16-87. enclosure suitable for one operating device and two pilot lights. See Field Mods page 16-79. Clamshell 16-90 361.00 422.00 422.00 422.00 List Price $ 49EB30EW131306R 689.00 49EB30GW161808R 1301.00 49EB22JW302410R 2791.00 49EB22JW302410R 2791.00 Catalog Number 49EB30GW161808R 49EB22IW261808R 49EB22JW302410R 49EB22JW302410R Industrial Use, Weatherproof Max CPT List VA Price $ 1301.00 2791.00 2791.00 2791.00 Hinged cover enclosure suitable for one or more class 52 operating devices and one or more class 52 pilot lights. See Field Mods page 16-79. Install NEMA 1 hole plug cat. no. 3SB1902-0AR (included) when the cover OL reset is not needed. Install NEMA 12 hole plug cat. no. 52ABH6 (not included) when the cover OL reset is not needed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog With CPT (Extra Wide) Model B Enclosure Catalog Number List Price $ Catalog Number 49EB30E0131306R 49EB30G0161808R 49EB22J0302410R 49EB22J0302410R 293.00 603.00 1326.00 1326.00 49EB30G0161808R 49EB22I0261808R 49EB22J0302410R 49EB22J0302410R Max CPT List VA Price $ 603.00 1326.00 1326.00 1326.00 Install NEMA 4X stainless steel hole plug cat. no. 52ABHS (not included) when the cover OL reset is not needed. Discount Schedule NEMA Heavy Duty Control Lighting Enclosure Tables Selection Lighting & Heating Contactors Class LE NEMA 4/4X Stainless NEMA 1 General Purpose (Clamshell) NEMA 12/3/3R Watertight, Corrosion Resistant Industrial Use Without CPT With CPT (Extra Wide) Without CPT With CPT (Extra Wide) Without CPT With CPT (Extra Wide) Model C Enclosure Model C Enclosure Model B Enclosure Model B Enclosure Model B Enclosure Model B Enclosure Size Pole Catalog Number List Price $ Catalog Number Max CPT List Price $ Catalog Number List Price $ Catalog Number Max List CPT Price $ Catalog Number 20A 30A 30A 30A 60A 60A 60A 100A 61.00 61.00 235.00 235.00 61.00 235.00 235.00 235.00 200VA 200VA 200VA 250VA 200VA 200VA 250VA 200VA 235.00 235.00 235.00 361.00 235.00 235.00 361.00 235.00 1301.00 1301.00 1861.00 1861.00 1301.00 1861.00 1861.00 1861.00 49EB22GW161406R 49EB22GW161406R 49EB14JW261408R — 49EB22GW161406R 49EB14JW261408R — 49EB14JW261408R — — — — — — — — 49EB22G0161406R 603.00 49EB22G0161406R 603.00 49EB14J0261408R 1102.00 49EB14J0261408R 1102.00 49EB22G0161406R 603.00 49EB14J0261408R 1102.00 49EB14J0261408R 1102.00 49EB14J0261408R 1102.00 2-12 3 6-9 12 3 6-9 12 3 49EC14EB110705R 49EC14EB110705R 49EC14IB201208R 49EC14IB201208R 49EC14EB110705R 49EC14IB201208R 49EC14IB201208R 49EC14IB201208R 49EC14IB201208R 49EC14IB201208R 49EC14IB201208R 49EC14JB251409R 49EC14IB201208R 49EC14IB201208R 49EC14JB251409R 49EC14IB201208R 49EB22GW161406R 49EB22GW161406R 49EB14JW261408R 49EB14JW261408R 49EB22GW161406R 49EB14JW261408R 49EB14JW261408R 49EB14JW261408R 1301.00 1301.00 1861.00 — 1301.00 1861.00 — 1861.00 List Price $ Catalog Number 49EB22G0161406R 49EB22G0161406R 49EB14J0261408R — 49EB22G0161406R 49EB14J0261408R — 49EB14J0261408R Max List CPT Price $ — 603.00 — 603.00 — 1102.00 — — — 603.00 — 1102.00 — — — 1102.00 Lighting & Heating Contactors Class CLM General Purpose (Clamshell) NEMA 4/4X Stainless Watertight, Corrosion Resistant NEMA 12/3/3R Without CPT Without CPT With CPT (Extra Wide) Without CPT Model B Enclosure Model B Enclosure NEMA 1 With CPT (Extra Wide) Model C/B Enclosure Size Pole Catalog Number 20A 30A 30A 60A 60A 100A 2-12 2-5 6-12 2-5 6-12 2-5 Model C/B Enclosure List Price $ Catalog Number 49EC14GB140807R 130.00 49EC14EB110705R 61.00 49EB30GB161808R 422.00 49EC14GB140807R 130.00 49EB30IB192208R 448.00 49EC14IB201208R 235.00 49EC14IB201208R 49EC14IB201208R 49EB30GB161808R 49EC14IB201208R 49EB30IB192208R 49EC14IB201208R Model B Enclosure Max CPT List Price $ Catalog Number 200VA 200VA 200VA 200VA 250VA 200VA 235.00 235.00 422.00 235.00 448.00 235.00 List Price $ Catalog Number Industrial Use Max List CPT Price $ Catalog Number With CPT (Extra Wide) Model B Enclosure List Price $ Catalog Number 49EB22GW161406R 1301.00 49EB22GW161406R — 1301.00 49EB22G0161406R 603.00 49EB22G0161406R 49EB22GW161406R 1301.00 49EB22GW161406R — 1301.00 49EB22G0161406R 603.00 49EB22G0161406R 49EB30GW161808R 1301.00 49EB30GW161808R — 1301.00 49EB30G0161808R 603.00 49EB30G0161808R — — — — — — — — — — — — — — — — — — — — — — — — Max List CPT Price $ — — — — — — 603.00 603.00 603.00 — — — 16 CONTROL PRODUCTS NEMA & General Purpose Control Note: Dimensions...See appropriate Product Class Outline Drawing beginning on page 16-115. For conduit hubs and conversion instructions, see page 16-87. enclosure suitable for one operating device and two pilot lights. See Field Mods page 16-79. Clamshell Discount Schedule NEMA Hinged cover enclosure suitable for one or more class 52 operating devices and one or more class 52 pilot lights. See Field Mods page 16-79. Install NEMA 1 hole plug cat. no. 3SB1902-0AR (included) when the cover OL reset is not needed. Install NEMA 12 hole plug cat. no. 52ABH6 (not included) when the cover OL reset is not needed. Install NEMA 4X stainless steel hole plug cat. no. 52ABHS (not included) when the cover OL reset is not needed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-91 Combination Starter Enclosure Kits Features and Benefits Features ▪ Manufactured with a cold forming “TOX” process ▪ 100kA short circuit rating when protected with class R fuses to 600V or MCP to 480V and when installing listed components from the instruction guide ▪ Enclosure types available, Nema 1, 12, 3/3R and painted NEMA 4. Nema 12 field convertible to 3/3R/4 with the appropriate conduit hub and drain hole ▪ Pre-Drilled mounting panels ▪ Heavy duty quarter turns ▪ Industrial type disconnect handle Disconnect Type Enclosure Kit ▪ Used to assemble both non-fusible and fusible combination starters ▪ Accommodates Class 14 full voltage non-reversing (FVNR) NEMA starters 00 – 4 including Siemens exclusive half sizes ▪ Handle mechanism, power wire, mounting panel, reset assembly, and instruction guide included. Hardware for panel mounted devices and disconnect switch are not included NEMA & General Purpose Control CONTROL PRODUCTS 16 MCP Type Enclosure Kit ▪ Used to assemble combination starters with circuit breakers ▪ Accommodates Class 14 full voltage non-reversing (FVRN) NEMA starters 00 – 4 including Siemens exclusive half sizes ▪ Handle mechanism, power wire, mounting panel, reset assembly and instruction guide included. Circuit breaker not included however, mounting hardware for the circuit breaker is How to Select the Required Kits to Assemble a Combination Starter 1. From the catalog, select a class 14 open type starter with the required starter size and overload relay type. 2. Based on the starter size, select the enclosure kit from table 1a for fusible or non-fusible combination starters or select from table 1b for combination starters with an MCP. 3. For a non-fusible combination starter, select the disconnect switch kit from table 2a. For a fusible combination starter, select the appropriate disconnect switch, fuse clip kit, and class R rejection kit from table 2b (for H fusing, class R rejection kit not required). For combination starters with MCP, select the appropriate circuit breaker kit from table 3. Nomenclature for Combination Enclosure Kits 49 E C 17 B B 24 11 08 R Class 49 — Field Kit Reset Installation R — Reset Installed Type E — Enclosure Kit Depth (In Inches) Width (In Inches) Model C — Model C Product Class 17 — Disconnect Type 18 — Circuit Breaker Type Height (In Inches) Enclosure Type B — NEMA 1 N — NEMA 12/3R, 4 Painted Disc / CB Amp Rating B — 30/60 amp disconnect C — 100 amp disconnect D— 125 amp breaker frame E — 150 amp breaker frame F — 200 amp disconnect 16-92 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Combination Starter Enclosure Kits Selection Table 1a - FVNR Combination Starter Kits for use with Disconnect Devices Starter Size 0-2 2 1⁄2 - 3 3 1⁄2 - 4 Disc. Amp Rating NEMA 1 Nema 12, 3/3R, 4 Painted 햲 General Purpose Industrial Use, Weatherproof, Watertight, Dust-tight Catalog Number 60 100 200 List Price $ Catalog Number List Price $ 292.00 390.00 901.00 49EC17BN241108R 49EC17CN242008R 49EC17FN362408R 334.00 546.00 948.00 49EC17BB241108R 49EC17CB242008R 49EC17FB362408R Table 1b. – FVNR Combination Starter Kits for use with MCP Devices Starter Size Max MCP Amps 0-2 2 1⁄2 - 3 3 1⁄2 4 50 100 125 150 Nema 12, 3/3R, 4 Painted 햲 NEMA 1 General Purpose Industrial Use, Weatherproof, Watertight, Dust-tight Catalog Number List Price $ Catalog Number List Price $ 292.00 390.00 824.00 901.00 49EC18DN241108R 49EC18DN242008R 49EC18DN362408R 49EC18EN362408R 334.00 546.00 877.00 948.00 49EC18DB241108R 49EC18DB242008R 49EC18DB362408R 49EC18EB362408R Table 2a – Non-Fusible Disconnect Kits Disconnect Switch Switch Rating 30A 60A 100A 200A Catalog Number List Price $ HNB612 HNB623 HNB623 HNB64 77.00 313.00 313.00 327.00 Table 2b – Fusible Disconnect Kits Disconnect Switch Catalog Number 30A-250V 30A-600V 60A-250V 60A-600V 100A-250V 100A-600V 200A-250V 200A-600V H H H H H H H H HFB21 HFB612 HFB22 HFB62 HFB63 HFB63 HFB64 HFB64 Fuse Clip Kit List Price $ Catalog Number 84.00 137.00 141.00 169.00 208.00 208.00 447.00 447.00 HBB21 HBB612 HBB22 HBB62 HBB63 HBB63 HBB64 HBB64 Rejection Clips for Class R Fusing List Price $ 56.00 81.00 83.00 97.00 176.00 176.00 256.00 256.00 Catalog Number HR21 HR612 HR612 HR62 HR63 HR63 HR64 HR64 List Price $ 83.00 83.00 83.00 83.00 54.00 54.00 54.00 54.00 CONTROL PRODUCTS Class 16 Fuse Clip Ratings Table 3 – Circuit Breaker Kits MCP Type Used with Solid State Overload Relay 0 1 1 3⁄4 2 2 1⁄2 3 3 1⁄2 4 햲 Overload Amp Range Motor Circuit Interrupter Amps Circuit Breaker Kit Motor Circuit Interrupter Amps Circuit Breaker Kit 0.75-3 2.5-10 9-18 3 10 25 ED63A003 ED63A010 ED63A025 3 10 25 ED63A003 ED63A010 ED63A025 0.75-3 2.5-10 9-18 13-27 13-27 20-40 13-27 22-45 22-45 30-60 30-60 45-90 57-115 67-135 3 10 25 30 40 50 40 50 50 100 50 100 125 150 ED63A003 ED63A010 ED63A025 ED63A030 ED63A040 ED63A050 ED63A040 ED63A050 ED63A050 ED63A100 ED63A050 ED63A100 ED63A125 FXD63A150L 3 10 25 30 40 50 40 50 50 100 50 100 125 150 ED63A003 ED63A010 ED63A025 ED63A030 ED63A040 ED63A050 ED63A040 ED63A050 ED63A050 ED63A100 ED63A050 ED63A100 ED63A125 FXD63A150L NEMA & General Purpose Control Starter Size MCP Type Used with Thermal Overload Relay For conduit hubs and conversion instructions, see page 16-87. Discount Schedule NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-93 Factory Modifications Selection Ordering Information 䊳 䊳 All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction may not apply when certain modifications and special features are added. Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number. Example: 14DSE32BA becomes 14DSE32BAA1. Pilot Devices Description Modification Class Enclosure Type Push Buttons Start, Stop Forward, Reverse, Stop High, Low , Stop E-Stop Test Push Buttons 14, 17, 18, 36, 37, 40, 83, 84, CLM, CM, LE 22, 25, 26, 43 30, 32 14햲 , 17, 18, 22햲 , 25, 26, 30햲 , 32, 36, 37, 40햲 , 43햲 83, 84 14, 17, 18, 36, 37, 40, 83, 84, LE CM, CLM All All햲 All All햲 All All All For 24 volt HOA control, 20 Amp contactor only CM, CLM Off-On Auto-Off Forward-Off-Reverse High-Off-Low Hand-Off-Auto (Keyed) Auto-Off-Low-High Hand-Off-Auto Selector Switches Suffix List Price $ A1 200.햶 A2 360. ES K1 A3 A3 271. 200. 200.햶 780. 1 EM 736. 14, 17,18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, CLM, CM, LE All A4 200.햶 14, 17, 18, 40, 83, 84, CM, CLM, LE 22, 25, 26, 43 30, 32 14, 17, 18, 36, 37, 40, 83, 84, LE, CLM, CM 30, 32 All햲 All All All 햲 All햲 A6 200.햶 A5 200. A9 A0 601.햶 227. CONTROL PRODUCTS 16 Pilot Lights Lens Color ➔ Red Legend➔ Suffix ➔ Green Red White Red Push-To-Test Green Push To-Test OL Tripped Control Power On On For/Rev Low/High On For/Rev Low/High Off FK FL햵 FW 햲 FS햲 FT 햲 FU햲 315. 315. 315. 215. 273. 273. 375. 315. 315. 315. 215. 548. 548. 375. Green Red Green Amber On On For/Rev For/Rev Low/High Low/High Run Run Off Off FA FB FC FD FJ 215. Class Enclosure Type 14, 40, 17, 18, 36, 37, 87, 88, LE, CLM, CM All 215. 215. 215. 22, 25, 26, 30, 32, 43, 83, 84 All 429. 429. 409.햹 409.햹 Green Push To-Test Coil Options NEMA & General Purpose Control Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83햷 , 84햷 , 87, 88 Controller Size — List Price $ AC (50–60 HZ) or DC Coil Letter Change 23–26V 42–48V 110–127V 200–220V 220–240V 240–277V 380–420V 440–480V 575–600V J U F D G L K H E Volts 60 HZ Volts 50 HZ Coil Letter Change 00–21⁄2 3, 31⁄2 4 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 24 110 110/190–220 — 190–220 240 190–220/380–440 380–440 550 J F A D G L C H E NC NC NC DC Coil 햴 24V 48V 125V 250V S햸 U V W 156. 햲 NC Miscellenious Options Not Available on Class 14, 40, 22, 43, 30 (size 00–4) and Class LE, CLM (20–30amp) NEMA 1 clamshell enclosures. 햳 DC coils include 1 NC, late break aux. contact. This aux. contact takes up one side of the starter (00–4 only). 16-94 Controller Size 4 (Vacuum Only) Size 5 & 6 (ALL) 302. 402. Omit Alternator (deduct) Duplex with Separate Relay Alternation Duplex with lead pump transfer switch 햴 햵 Price x 2 for Classes 22, 25, 26, 30, 32, 43, 83, 84. Bimetal OL - Size 00 - 2 1/2 available. Solid-state OL Size 00 - 4, 7 & 8 available. 햶 For Class 83, 84 two devices are provided. Price x 2. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 햷 햸 햹 Class Change the 92 to List Price $ 83, 84 95 222. 83, 84 93 NC 83, 84 94 NC For Class 83, 84 standard enclosure (92) alternating relay available in 24V or 120V control only. S coil is not available for size 4 contactors or starters. Class 83 and 84 only. Discount Schedule NEMA Factory Modifications Selection Ordering Information 䊳 䊳 䊳 Transformer Table Primary Volts 120 208 208 240 240 277 277 380 415 480 480/240 480/240 600 600 Replace (*) with letter from Transformer Table. Prices shown are additions to standard equipment prices as listed in the catalog and are not to be used as separate selling prices. All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction may not apply when certain modifications and special features are added. Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number. Example: 14DSE32BA becomes 14DSE32BABB. Secondary Volts 24 24 120 24 120 24 120 110 100 240 24 120 24 120 Letter B S T J F N P U W R D A E C Control Power Transformers Description Standard Capacity with 1-Secondary Fuse Standard Capacity with 2-Primary and 1-Secondary Fuse 100VA Extra Capacity with 2-Primary and 1-Secondary Fuse 150VA Extra Capacity with 2-Primary and 1-Secondary Fuse Catalog No Suffix B* D* C* C*1 Product Class Enclosure 20–60 Type 0–2 1⁄2 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83 , 84 , 87 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83 , 84 , 87, LE, CLM, CM 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83 , 84 , 87, LE, CLM, CM 36, 37, 88 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83 , 84 , 87, LE, CLM, CM 36, 37, 88 1, 3, 4, 12 7&9 247. 284. 100 — 200 300–400 — — 3 31⁄2, 4 5 6 7 8 — — — — — — — — 905. 905. — — — — 1, 3, 4, 12 447. 712. 712. 822. 822. 7&9 484. 753. 753. 868. 868. 1050. 1050. 1, 3, 4, 12 7&9 All 636. 675. 831. 913. 1068. 1082. 913. 1068. 1082. 1004. 1233. 1197. 1004. 1233. 1197. 1095. 1095. 1373. 1373. — — 1, 3, 4, 12 795. 1088. 1088. 1179. 1179. 1179. 1179. All 986. 1288. 1288. 1361. 1361. — Lighting & Heating Ratings (Amps) Motor Controller Size — 16 Factory Assembled Fuse Clips—Class 25, 32, 84 250 600 250 600 250 600 250 600 250 600 250 600 600 600 Rejection Clip Suffix Note: Factory will furnish the same voltage coils as transformer secondary voltage (except with class 36,37). The standard control transformer supplied for starter sizes 0 through 21⁄2 will be rated 45VA and have the appropriate secondary fuse. Primary fuses will not be Discount Schedule NEMA List Price $ 10 11 12 13 14 15 16 17 18 19 20 21 23 25 27. 47. 47. 65. 146. 146. 329. 329. 675. 675. 969. 969. 2180. 5449. supplied as standard. For primary fuse option select appropriate suffix from table. ESP100 styles add the rejection clip suffix to the end of the base style catalog number. For thermal styles add the rejection clip suffix immediately before the 81 in the part number. For NEMA & General Purpose Control 30 30 60 60 100 100 200 200 400 400 600 600 800 1600 Volts CONTROL PRODUCTS Fuse Clip Amps For Class J fuse clips, add suffix ”DJ”. Class 84 Duplex Controllers require two fusible disconnects thus multiply the price adder by two. x 2 Class 83 and 84. Price Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-95 Factory Modifications Selection Ordering Information 䊳 䊳 Prices shown are additions to standard equipment prices as listed in the catalog and are not to be used as separate selling prices. All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction may not apply when certain modifications and special features are added. Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number. Example: 14DSE32BA becomes 14DSE32BAGO1. Additional Auxiliary Contacts Class 햴 NEMA & General Purpose Control CONTROL PRODUCTS 16 14, 17, 18, 40, 83 , 84 햴 22, 25, 26, 43 & 30, 32 (2-winding) 30, 32 (1-winding) LE, CLM, CM CLM, CM Controller Size — List Price $ NO Contacts NC Contacts Catalog Number Suffix 00–13⁄4 2–4 5–6 7–8 — — 1 2 G01 G02 102. 201. 102. 201. — 201. — — 1 1 1 — 1 2 G10 G11 G12 102. 201. 303. 102. 201. 303. — 201. — — 201. — 2 2 2 2 — 1 2 3 G20 G21 G22 G23 201. 303. 403. 505. 201. 303. 403. 505. 201. — 403. — — — — — 3 3 3 1 2 3 G31 G32 G33 403. 505. 604. 403. 505. — 403. — — — — — 4 4 4 4 — 1 2 4 G40 G41 G42 G44 403. 505. 604. 806. 403. 505. — — 403. — — — — — — — 5 5 5 — 1 3 G50 G51 G53 505. 604. 806. 505. — — — — — — — — 6 6 — 2 G60 G62 604. 806. — — — — — — 7 1 G71 806. — — — 8 — — 2 G80 G02햲 806. 201. — 201. — — — — 2 2 4 4 6 8 0 2 2 4 4 6 8 1 0 2 2 — 2 0 4 2 0 2 — 2 — 4 2 — 1 2 0 2 G20햲 G22햲 G40햲 G44햲 G62햲 G80햲 G02햲 G20햲 G22햲 G40햲 G44햲 G62햲 G80햲 G11 G02햲 G20햲 G22햲 201. 403. 403. 806. 806. 806. — — 403. 403. — — — 201. 201. 201. 201. 201. 403. 403. 806. 806. 806. 201. 201. 403. 403. 806. 806. 806. — — — — — 403. 403. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Overload Options Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37 Description Ambient Compensated Bimetal ESP100 or 3RB20 (Sz 5-6) 햲 Auxiliary Trip Class Class 10 or 20 (K or E heaters) Class 10 Class 30 Phase NO & NC, SPDT 3-Phase or Single Phase NC NC 3-Phase NC contacts will be added evenly across contactors. (i.e. Class 22, G02 suffix will add 2 NC contacts (one per contactor). 16-96 Contacts Catalog Number Suffix Controller Size—List Price $ 00–21⁄2 햳 3–4 5, 6 91 54. — — 81 51 53 NC NC NC — NC NC — NC — 햳 Double the price addition for Class 30 and 32. 햴 For class 83 and 84 contacts will be added to both starters. Price x 2. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA Factory Modifications Selection Ordering Information 䊳 䊳 Prices shown are additions to standard equipment prices as listed in the catalog and are not to be used as separate selling prices. All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction may not apply when certain modifications and special features are added. Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number. Example: 14DSE32BA becomes 14DSE32BAA1. Control Options Description Class Enclosure Type Catalog Number Suffix List Price $ Lighting Control Modules Surge Suppression for 120V AC Coil Disconnect Switch Interlock 2 NO/2 NC DPDT Motor Circuit NO/NC SPDT Protector Interlock Lightning Arrestor Circuit Breaker Shunt Trip Circuit Breaker Undervoltage Trip Circuit Breaker Alarm Switch Trip NO alarm aux contact for ESP OL Ground Lug – 1 Conductor Control Circuit Fuse and Holder (Transformer Primary Fusing) Control Circuit Circuit Breaker Internally Operated Space Heater (120V separate control) Space Heater with Thermostat (120V separate control) Surge Capacitor Alarm Package (includes horn, light, relay & push-button) Backspin Protection Minimum Run Timer 0.2 sec. - 3 mins. Blown Fuse Indicator Light Single Phase 120VAC Combination Starter Single Phase 240VAC Combination Starter CLM 20 Amp 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 83, 84, 87, 88 17, 25, 32, 37, CM, LE All All 1, 3, 4, 4X, 12 2W, 3W, 3WS SS GY 466. 725. 765. 82. 134. 18, 26, 32, 37, CM, LE All GY 264. All 18, 26, 32, 37, 84, 87, 88, CM, LE 18, 26, 32, 37, 84, 87, 88, CM, LE 18, 26, 32, 37, 84, 87, 88, CM, LE 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 83, 84, 87, 88 All All All All All All All All All L L6 L7 L8 L9 L10 F1 (1 fuse) F2 (2 fuses) 365. 753. 753. 753. 50. 73. 200. 200. All All F4 795. All All 87, 88 83, 84, 87, 88 87, 88 87, 88 17, 25, 32, 37, 84, 87, 88, CM, LE 17, 18 17, 18 All All All All All All All All All SH ST SC M7 T5 T6 L11 Z1 Z1 16 639. 686. 439. 1371. 712. 712. 456. NC NC Description Class Reversing in one speed only 2 speed 1 winding Reversing in one speed only 2 speed 2 winding Reversing in both speeds 2 speed 1 winding Reversing in both speeds 2 speed 2 winding Reversing for Reduced Voltage 30, 32 36, 37 Catalog Number Suffix R6 R7 R8 R9 R Controller Size —List Price $ 0 1 13⁄4 2 21⁄2 3 31⁄2 4 5 1033. 1000. 1395. 1551. 1240. 1095. 1137. 1607. 1772. 1314. 1335. 1361. 2158. 2518. 1314. 1571. 1602. 2539. 2962. 3597. 1940. 2003. 3213. 3618. 3597. 2281. 2356. 3780. 3617. 8237. 2620. 2702. 4983. 4937. 8237. 3081. 3181. 5862. 5809. 8237. — — — — 9844. NEMA & General Purpose Control Enclosure Options Class 36, 37 Controller Size — List Price $ Class Enclosure Type Change the 8th Character of the Catalog Number to: 0–13⁄4 2, 21⁄2 3 31⁄2, 4 5 6 36 37 37 NEMA 12/3R NEMA 4 (Painted) NEMA 4 (Stainless Steel) N E W 913. 1095. 1314. 1142. 1233. 1479. 1371. 1781. 2137. 1826. 2804. 3363. 2466. 5205. — 3425. 6850. — Change the 7th Character of the Catalog Number with Bimetal OL to: X X X Change the 8th Character of the Catalog Number with ESP OL to: X X X Enclosure Options Class 14, 17, 18 Class 14 14 (Extra Wide) 17 & 18 Enclosure Type NEMA 4/4X (316 Stainless Steel) NEMA 4/4X (316 Stainless Steel) NEMA 4/4X (316 Stainless Steel) Controller Size – List Price Adder $ 00–1 3/4 50. 87. 272. 2–2 1/2 165. 87. 272. 3 165. 189. 272. 3 1/2–4 165. 189. 390. 5–8 — — — Note: Add price to the standard 304 stainless steel unit price. Supplied as NEMA 12, field convertible to NEMA For bimetal OL, order cat. no. with ”91” suffix. Specify the single phase voltage when ordering. Discount Schedule NEMA 3R. CONTROL PRODUCTS Reversing Options Surge Suppression for NEMA sizes 5 – 8 are supplied internal with the coil. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-97 Factory Modifications Dimensions Ordering Information 䊳 䊳 Prices shown are additions to standard equipment prices as listed in the catalog and are not to be used as separate selling prices. All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction may not apply when certain modifications and special features are added. Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number. Example: 14DSE32BA becomes 14DSE32BAR40. Control Relays Description 4 NO 2 NO/2 NC 4 NC Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (460V) Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (230V) Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (575V) Ground Fault Relay Electronic On Delay Relay (.15s–100h) 24V/120V Electronic On Delay Relay (.15s–100h) 24V/240V Electronic Off Delay Relay (.15s–100s) 120V Electronic Off Delay Relay (.15s–100s) 240V 24 hour time clock 24 hour time clock with day omission 7 day time clock Compelling Relay Acceleration Control Deceleration Control Control Relay 4-Poles Max Class Enclosure Type All 1, 3, 4, 7, 9, 12 Suffix R40 R22 R04 R1 R2 R4 R5 T1 T2 T3 T4 T7 T8 T9 A6 A7 A8 1, 3, 4, 7 & 9, 12 All 1, 3, 4, 7, 9, 12 LE, CLM, CM All 30, 32 1, 4, 12 List Price $ 1077. 1007. 536. 1004. 1004. 602. 1371. CONTROL PRODUCTS 16 Meters—Mounted on Enclosure Enclosure Type Description Class Ammeter (includes a C.T. if necessary) Ammeter and Switch (3-Phase with 3 C.T.’s) Voltmeter Voltmeter and Switch (3-Phase) Elapsed Time Meter Wattmeter 14 , 17, 18, 22 , 1, 12 25, 26, 36, 37, 40 , 43 , 83, 84 Suffix List Price $ M1 M2 M3 M4 M5 M6 1807. 2739. 1807. 2739. 530. 3706. NEMA & General Purpose Control Function Identification Plates Description Class Suffix Function identification plate, with marking as specified All N1 List Price $ 89. Terminal Blocks Description Class 3 Point Terminal 6 Point Terminal 9 Point Terminal Suffix TC3 TC6 TC9 All List Price $ 219. 439. 658. Special Ratings Description Class Suffix Service Entrance Rating 17, 18, 25, 26, 32, 37, 84, 87 N3 Supplied mounted and unwired. Not available on Class 36, 37. Price x 2 Class 83 and 84. 16-98 List Price $ 237. ETM available with 120V coil For terminal point more than only. 9 terminals use additional suffixes. Max 3 suffixes can be selected. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Available 3-Phase only. Discount Schedule NEMA Manual Control Class SMF, MMS Dimensions Class SMF and MMS Open Type NEMA Type 3R, 4 and 12 (Top and Bottom) Class SMF FO–1, 1P, 2, 2P (with toggle operator) Types Class MMS KO–1, 1A, 1B, 2, 2B, 2C (with toggle operator) Types NEMA Type 1B General Purpose Flush Mounting Device Class Fractional HP Starter SMF Motor Starting Switch MMS Type FWN1, 1P, FWN2, 2P FWN3, 3P, FW4, 4P KWN1, 1A, 1B, KWN2, 2B, 2C KWN3, 3A, 3B, KWN4, 4B, 4C NEMA Type 4 Watertight Die Cast Zinc Enclosure Type of Operator Dimensions in Inches (mm) A B C FF1, 1P, 2, 2P FS1, 1P, 2, 2P 1.44 (37) 1.44 (37) 1.44 (37) 1.44 (37) 1.75 (44) 1.75 (44) 1.75 (44) 1.75 (44) 2.75 (70) 3.50 (89) 2.75 (70) 3.50 (89) 2.75 (70) 3.50 (89) 2.75 (70) 3.50 (89) 4.50 (114) 5.25 (133) 4.50 (114) 5.25 (133) 4.50 (114) 5.25 (133) 4.50 (114) 5.25 (133) FSJ1P, 2P Key FF3, 3P, 4, 4P FS3, 3P, 4, 4P FSJ3P, 4P Class MMS Motor Starting Switch Toggle KF1, 1A, 1B, 2, 2B, 2C KS1, 1A, 1B, 2, 2B, 2C KSJ1A, 1B, 2B, 2C Key KF3, 3A, 3B, 4, 4B, 4C KS3, 3A, 3B, 4, 4B, 4C KSJ3A, 3B, 4B, 4C Dimensions in Inches (mm) A B C D E F G H I 3.00 (76) 2.75 (70) 1.13 (28) 0.25 (6) 3.75 (95) 4.69 (119) 4.25 (108) 4.56 (116) 0.78 (20) Device Class Type Fractional HP Starter Motor Starting Switch SMF MMS FW1, 1P, 2, 2P KW1, 1A, 1B, 2, 2B, 2C NEMA & General Purpose Control Type CONTROL PRODUCTS Toggle Class SMF Fractional HP Starter 16 Device NEMA Type 1 General Purpose Surface Mounting Enclosures Standard Size—Class SMF and MMS Types FG & KG (Single-Unit) Note: Dimensions for reference, not for construction. Dimensions are in inches (mm). Oversized—Class SMF and MMS Types FGJ & KGJ (Single-Unit) Dimensions 1⁄ 2⬙– 3⁄ 4⬙ Jumbo MMSKE2 Knock-Out On Back and Sides typical for key operator devices. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-99 Manual Control Class SMF, MMS Dimensions NEMA Type 7 and 9 Cast Aluminum Enclosure Dimensions in Inches (mm) A B C D G H 4.00 (101) 5.75 (146) 1.38 (35) 6.36 (161) 4.38 (111) 1.20 (30) Device Class Type Fractional HP Starter Motor Starting Switch SMF MMS FR1, FR2 KR1, KR2 NEMA Type 1 General Purpose Enclosure For Two Unit Devices Type of Operator Class Type One Starter and One Sel. Switch Toggle Key Toggle Key Toggle Key SMF SMF SMF SMF SMF SMF Reversing Switch Toggle MRS Two Speed Starter Two Speed Switch Toggle Toggle SMF MMS FG02, 02P FG04P FG222, 222P FG44P FG71, 71P, 72, 72P FG74P KG11, 11A, 11B, 22, 22A, 22B, 22C FG11, 11P, 22, 22P KG11, 11A, 11B, 22, 22B, 22C Device One Starter CONTROL PRODUCTS 16 Two Starters NEMA Type 1B General Purpose Flush Mounting For Two Unit Devices Device Type of Operator Class Type FF22, 22P NEMA & General Purpose Control Toggle SMF FS22P Two Starters FF44P Key SMF FS44P FF71, 71P, 72, 72P One Starter and One Selector Switch Toggle SMF FS71P, 72P FF74P Key SMF FS74P Reversing Switch Two Speed Switch Two Speed Switch A B C D 5.25 (133) 4.56 (116) 5.25 (133) 4.56 (116) 5.25 (133) 4.56 (116) 5.25 (133) 4.56 (116) 3.75 (95) 3.50 (89) 3.75 (95) 3.50 (89) 0.75 (19) 3.50 (89) 3.75 (95) 3.50 (89) 5.25 (133) 4.50 (114) 5.25 (133) 4.50 (114) 5.25 (133) 4.50 (114) 5.25 (133) 4.50 (114) 1.44 (37) 1.44 (37) 1.44 (37) 1.44 (37) 2.00 (51) 2.00 (51) 2.00 (51) 2.00 (51) Toggle MRS KF11, 11A, 11B KF22, 22A 22B, 22C 5.25 (133) 3.75 (95) 5.25 (133) 1.75 (44) Toggle SMF FF11, 11P, 22, 22P 5.25 (133) 3.75 (95) 5.25 (133) 1.44 (37) Toggle MMS KF11, 11A, 11B 22, 22B, 22C 5.25 (133) 3.75 (95) 5.25 (133) 1.44 (37) Note: Dimensions for reference, not for construction. Dimensions are in inches (mm). Selector switch is on the left, increases overall depth to 3.50 in. (89 mm). one pilot light (located on right) is used on MRS switches. Only 16-100 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Dimensions include factory wired power connections. Selector switch is on the left, extends 1.62 in. (41 mm) from mounting surface. Manual Control Class 11 - 3RV Dimensions 3RV102 Class 11 - NEMA 7 & 9, 3 & 4, and NEMA 7 & 9 Enclosure Class 11 - NEMA 1 Enclosure 1/2 NPT 16 1/2 - 3/4 NPT 3/4 - 1 NPT 3/4 NPT 3/8 Mounting Screw 1/2 - 3/4 NPT 1/2 - 3/4 NPT CONTROL PRODUCTS 1/2 - 3/4 NPT 9.88 10.20 9.19 8.50 4.63 1/2 - 3/4 NPT NEMA & General Purpose Control 8.63 6.06 6.38 7.50 1/2 - 3/4 NPT 6.39 1/4 Mounting Screw Typ. (3) Places 5.05 3/4 NPT 6.97 5.81 1/2 - 3/4 NPT 3/4 - 1 NPT .50 Note: Dimensions in inches (millimeters). Dimensions for reference, not for construction. Contact Sales Office for dimensions not listed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-101 Heavy Duty Motor Starters Solid State Overload, Class 14 Dimensions Figure 2 Figure 1 B1 C C1 D2 C B1 B .50 B .50 D2 C1 L L J A E J A E D D L RESET L L L K G E1 M M1 D1 G Figure 5 Figure 4 Figure 3 B1 B B1 C B C C1 D2 C1 E1 D1 B2 M M1 E2 D2 .50 L3 1 L A T1 J A D T2 T3 D J L L K M M1 E1 G M M1 D1 E1 K G CONTROL PRODUCTS 16 D1 Open Type Solid State Overload Outline Dimensions Reset Dimensions Size Figure A B B1 B2 C C1 D D1 D2 E E1 E2 G J K L M M1 00–13⁄4 1 7.44 3.50 5.75 — 3.75 3.50 6.50 2.00 0.19 6.27 1.00 — #10 5.55 — 0.26 3.06 3.22 (189) (89) (146) (95) (89) (165) (51) (5) (159) (25) (82) 2–21⁄2 2 8.13 3.50 5.75 4.60 4.00 3.77 7.62 2.00 0.19 — 1.00 — #10 (207) (89) (146) (117) (102) (96) (194) (51) (5) — 3–31⁄2 NEMA & General Purpose Control Mounting Screw Mounting Dimensions 4 5 6 3 4 5 5 9.78 4.50 6.75 (248) (114) (171) 11.06 4.50 6.75 (281) (114) (171) 12.76 5.71 6.89 (324) (145) (175) 13.03 6.30 7.48 (331) (160) (190) — — 4.66 5.19 9.22 1.44 0.28 (118) (132) (234) (37) (7) 4.66 5.75 10.34 1.44 0.44 (118) (146) (263) (37) (11) 8.54 — 7.09 4.72 — (180) (120) (217) — 9.29 (236) — 7.09 5.12 (180) (130) (25) — 0.72 — (18) — — (7) (78) 6.67 0.60 0.26 3.28 3.49 (169) (15) (7) (83) (88) 0.25 8.22 0.60 0.26 3.44 3.64 (6) (209) (15) (7) (87) (92) 0.72 0.72 0.25 9.16 0.72 0.26 3.44 3.64 (18) (18) (6) (233) (18) (7) (87) (92) — — 0.35 — — — — — — — — — — (9) — — — Note: Dimensions in inches (millimeters). Dimensions for reference, not for construction. Contact Sales Office for dimensions not listed. 16-102 (141) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog — 0.35 (9) Heavy Duty Motor Starters & Contactors Ambient Compensated Bimetal Class 14 Dimensions Figure 2 Figure 1 C C1 B1 .50 D2 B1 C B D2 C1 CL CL J A A D J D 3 PHASE L G 3 PHASE L SINGLE PHASE M1 M .50 B E SINGLE PHASE K M1 M E G Figure 3 D1 Figure 4 B1 B1 B .50 B .50 C C1 C C1 D2 E1 D2 CL 16 A J D CONTROL PRODUCTS J D A L L RESET R E S E T G D1 B2 M1 M G E NEMA & General Purpose Control M1 M E D1 B2 Open Type Ambient Compensated Bimetal Overload Size Outline Dimensions Figure A B B1 00–13⁄4 1 2–21⁄2 2 3–3 ⁄ 3 4 4 12 7.45 (189) 8.38 (213) 10.66 (271) 12.02 (305) 3.50 (89) 3.50 (89) 4.50 (114) 4.50 (114) 5.75 (146) 5.75 (146) 6.75 (171) 6.75 (171) C C1 Mounting Dimensions D D1 D2 3.89 (99) 4.00 (102) 5.06 (129) 5.75 (146) 3.50 (89) 3.77 (96) 4.66 (118) 4.66 (118) 6.50 (165) 7.75 (197) 9.25 (235) 10.34 (263) — 2.00 (51) 1.44 (37) 1.44 (37) 0.19 (4.8) 0.19 (4.8) 0.28 (7) 0.44 (11) Mounting Screw G E E1 1.00 (25) 1.00 (25) 0.72 (18) 0.72 (18) — #10 — #10 — 0.25 (6) 0.25 (6) 0.72 (18) Reset Dimensions J K L M M1 5.39 (137) 6.28 (160) 7.81 (198) 8.78 (223) 0.16 (4) 0.16 (4) 0.12 (3) 0.12 (3) 2.97 (75) 3.22 (82) 3.39 (86) 3.63 (92) 2.81 (71) 3.06 (78) 3.27 (83) 3.51 (89) — 0.36 (9) — — Note: Dimensions in inches (millimeters). Dimensions for reference, not for construction. Contact Sales Office for dimensions not listed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-103 Reversing & Multispeed Heavy Duty Starters Solid State Overload Class 22, 30 Dimensions Figure 1 Figure 2 B1 C B C1 Figure 3 B1 B D1 C .50 D1 B1 C1 C C1 B D1 J A D J A D J L D A A L L K G K1 CL B2 M1 M E M1 M B2 K L G K1 E K M1 M K1 E Figure 4 Figure 5 B1 B1 B C E D1 G C C1 E C1 D1 J J D A A D L L K K1 M1 M G B G K1 K M1 M Figure 6 Figure 7 B1 B1 C 16 E C E C1 D1 C1 CONTROL PRODUCTS D1 -1 L3 J D A J D A L K K1 L M1 M G K B K1 G M1 M NEMA & General Purpose Control B Class 22 Reversing & Class 30 2 Speed/2 Winding Size 00–13⁄4 2–21⁄2 3– 3 1⁄2 4 Figure Outline Dimensions A B B1 B2 C 1 2 3 4 7.69 8.94 11.44 11.91 3.62 3.62 — — 3.61 4.17 5.65 6.22 8.25 8.25 10.94 10.94 10.50 10.50 12.75 12.75 C1 Mounting Dimensions D D1 E Mounting Screw Reset Dimensions G J K K1 L M M1 3.92 3.98 5.03 5.11 7.25 8.50 10.75 11.22 #10 #10 #10 0.25 0.26 0.26 0.26 0.21 3.40 3.66 4.12 4.12 3.23 3.45 3.91 3.91 Mounting Screw Reset Dimensions G J K K1 L M M1 #10 #10 #10 #10 0.26 0.26 0.26 0.26 3.40 3.50 3.66 3.66 3.23 3.29 3.45 3.45 0.22 0.22 0.34 0.34 7.25 7.25 10.25 10.25 5.77 6.89 8.97 9.32 1.25 0.65 1.53 1.53 4.75 4.75 6.00 6.00 Class 30 2 Speed/1 Winding Size 00–1 3⁄4 2–2 1⁄2 3–3 1⁄2 4 Figure Outline Dimensions A B B1 B2 C C1 Mounting Dimensions D D1 E 1 5 6 7 7.69 9.19 11.44 11.91 3.62 — — — 3.61 3.94 5.65 6.22 3.92 3.85 5.07 5.12 7.25 8.75 10.75 10.75 8.25 14.55 16.94 16.94 10.50 16.30 18.75 18.75 0.22 0.22 0.34 0.82 7.25 13.00 16.25 16.25 Note: Dimensions for reference, not for construction. Contact sales office for dimensions not listed. Dimensions are in inches (mm). 16-104 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 5.77 7.14 8.97 8.87 1.25 0.65 1.53 1.53 4.75 5.75 6.00 6.00 Reversing & Multispeed Heavy Duty Starters Ambient Compensated Bimetal Overload Class 22, 30 Dimensions Figure 1b Figure 1a B1 B1 B .50 CL .50 CL B C C1 D1 .50 CL .50 CL CL J C C1 D1 CL J A A D NC R E S E T NC R E S E T M A N T R I P X2 T1 T2 R E S E T T R I P T1 T2 M A N T R I P X2 L T1 T 3 THIS OVERLOAD USED ON MULTISPEED STARTERS ONLY B2 K1 E K NC R E S E T NC M A N X2 T3 D T2 I T2 3 THIS OVERLOAD USED ON MULTISPEED STARTERS ONLY M1 G Figure 2 B1 B E L T B2 K1 E K M T R P T1 T3 M1 G M A N X2 M Figure 3 B1 B E C C1 D1 C C1 D1 .50 L L J J D A D A L RESET RESET RESE T RESE T L M1 M G K1 K G K M1 M K1 16 Figure 4 Figure 5 B B C C1 D1 B1 CONTROL PRODUCTS B1 C C1 D1 .50 CL CL CL L L J D J A A D NC L NC R E S E T R E S E T M A N T R I P X 2 T1 T2 M A N T1 T 3 T2 L T3 K1 G E K1 M1 M NEMA & General Purpose Control K K RESET RESET T R I P X 2 M1 M G E Class 22 Reversing & Class 30 2 Speed/2 Winding with Bimetal Overload Size Figure Outline Dimensions A B B1 00–13⁄4 2–21⁄2 3–31⁄2 4 1a 1b 2 3 7.69 8.94 11.44 12.50 8.25 8.25 10.94 10.94 10.50 10.50 12.94 12.75 B2 C 3.62 3.62 — — 3.92 4.17 5.66 6.22 C1 Mounting Screw D D1 3.61 3.98 5.08 5.16 7.25 8.50 10.75 11.22 0.22 0.22 0.34 0.34 E Mounting Dimensions G Reset Dimensions J K K1 L M M1 7.25 7.25 10.25 10.25 #10 #10 #10 0.25 5.60 6.46 8.56 9.11 4.75 4.75 6.00 6.00 0.16 0.16 0.12 0.12 3.12 3.10 3.83 4.09 3.07 3.05 3.71 3.97 E Mounting Dimensions G Reset Dimensions J K K1 L M M1 7.25 13.00 16.25 #10 0.25 0.25 5.60 6.71 8.56 4.75 5.75 6.00 0.16 0.16 0.12 3.12 3.10 3.83 3.07 3.05 3.71 1.25 0.79 2.12 2.12 Class 30 2 Speed/1 Winding with Bimetal Overload Size Figure Outline Dimensions A B B1 00–13⁄4 2–21⁄2 3–31⁄2 1a 4 5 7.69 9.19 11.44 8.25 14.56 16.94 10.50 16.25 18.75 B2 C C1 Mounting Screw D D1 3.62 — — 3.92 4.11 5.66 3.61 3.92 5.08 7.25 8.75 10.75 0.22 0.22 0.34 1.25 0.78 2.12 Note: Dimensions for reference, not for construction. Contact sales office for dimensions not listed. Dimensions are in inches (mm). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-105 Heavy Duty Contactors Class 40 Dimensions Full Voltage Open Type NEMA Contactor Size 00-8 Figure 1 Figure 2 CONTROL PRODUCTS 16 Figure 3 NEMA & General Purpose Control Figure 4 Open Type Mounting Dimensions Mounting Screw Size 3rd Character Outline Dimensions of Catalog No. Fig A B B1 B2 C D D1 E G 00–13⁄4 2–21⁄2 3–31⁄2 4 C, D, E F,G H, I J 1 1 1 1 4.31 (110) 4.88 (124) 6.13 (156) 7.81 (198) 3.94 (100) 3.94 (100) 5.13 (130) 5.19 (132) 4.25 (108) 4.25 (108) 5.50 (140) 5.50 (140) 4.75 (121) — — — 3.75 (70) 4.00 (102) 5.06 (129) 5.75 (146) 3.94 (100) 4.50 (114) 5.63 (143) 6.56 (167) 0.19 (5) 0.19 (5) 0.25 (6) 0.81 (21) 1.00 (25) 1.00 (25) 0.75 (19) 0.75 (19) #10 #10 0.25 (6) 0.5 (13) 5 6 L M 2 2 N P 3 4 5.71 (145) 6.3 (160) 8.27 (210) 17.23 (438) 6.89 (175) 7.48 (190) — — — — — — 8.54 (217) 9.29 (236) 9.53 (242) 10.56 (268) 7.09 (180) 7.09 (180) 9.80 (249) 12.28 (312) 4.72 (120) 5.12 (130) 2.83 (72) — — — — 5.35 (136) 0.35 (9) 0.35 (9) 7 8 8.27 (210) 8.43 (214) 14.05 (357) 15.41 (392) Note: Dimensions for reference, not for construction. Contact sales office for dimensions not listed. Dimensions are in inches (mm). 16-106 3rd character of catalog number identifies contactor rating. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 0.25 (6) 0.35 (9) Magnetic Reversing Contactors Class 43 Dimensions Figure 1 Figure 2 16 CONTROL PRODUCTS NEMA & General Purpose Control Open Type Horizontal Mounted Size 00–13⁄4 2, 21⁄2 3–31⁄2 4 5 6 Fig. 1 1 1 1 2 2 Outline Dimensions A B 7.69 (195) 7.75 (197) 8.94 (227) 7.75 (197) 11.44 (291) 10.94 (278) 8.50 (216) 10.94 (278) 18.07 (459) 14.20 (361) 11.61 (295) 18.88 (480) B1 9.25 (235) 9.25 (235) 11.50 (292) 11.50 (292) — 9.45 (240) C 3.88 (98) 4.56 (116) 5.19 (132) 6.25 (159) 9.44 (240) 10.85 (276) C1 — — — — — 7.44 (189) Mounting Dimensions D 7.25 (184) 8.5 (216) 10.75 (273) 7.81 (198) 17.20 (437) 10.44 (265) D1 0.25 (6) 0.25 (6) 0.38 (6) 0.38 (6) — 10.71 (272) E 3.63 (92) 3.63 (92) 5.13 (130) 5.13 (130) 9.61 (244) 17.72 (450) F — — — — 1.18 (30) Mouning Screw G #10 #10 0.25 0.25 — — Note: Dimensions for reference, not for construction. Contact sales office for dimensions not listed. Dimensions are in inches (mm). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-107 Overload Relays & Current Sensitive Relays Solid State Overload Dimensions Dimensions “A” Frame—ESP100 Solid State Overload Overload (55 - 630 Amps), SIRIUS 3RB20 Dimensions “A1” Frame—ESP100 Solid State Overload Dimensions “B” Frame—ESP100 Solid State Overload NEMA & General Purpose Control CONTROL PRODUCTS 16 ESP100 Overload Motor Lead Windows ESP100 Overload Motor Lead Windows Sizes 2–4 Current Sensitive Relay Free Standing Mounting Panel Note: Dimensions for reference, not for construction. Dimensions in inches. 16-108 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Overload Relays Panel Mounted Class 48 — Bimetal Dimensions Figure 1 Figure 2 Figure 4 Figure 3 Figure 6 Figure 5 16 Figure 8 Figure 7 CONTROL PRODUCTS Reset Dimensions C D E J 3 3⁄16 (81) 3 3⁄16 (81) 3 9⁄16 (90) 3 9⁄16 (90) 3 (76) 3 (76) 3 1⁄2 (89) 3 1⁄2 (89) 1 13⁄4 (44) 27⁄16 27⁄16 3 (76) Mounting Screw G Max Wire Size Approx Ship Wt Lbs (Kg) Ref Dwg #10 #10 #10 #10 8 1 00 250 MCM 2 (1) 2 (1) 3 (1) 4 (2) D51820 D51830 D51833 D52206 Description Fig A 1-Pole Bimetal Ambient Compensated 25 60 100 180 1 2 3 4 7 3 1⁄2 (89) ⁄8 (22) 4 7⁄8 (124) 7⁄8 (22) 4 7⁄8 (124) 1 1⁄4 (32) 5 15⁄16 (151) 1 1⁄4 (32) Description Amp Rating Fig A B C D E J K K1 K2 L 3-Pole Bimetal Ambient Compensated 30 60 100 180 5 6 7 8 3 5⁄8 (92) 3 7⁄8 (98) 4 7⁄8 (124) 6 1⁄2 (165) 3 1⁄16 (78) 3 1⁄16 (78) 4 7⁄16 (113) 4 7⁄16 (113) 3 1⁄8 (79) 3 1⁄8 (79) 3 9⁄16 (90) 3 9⁄16 (90) 3 (76) 3 (76) 3 1⁄2 (89) 3 1⁄2 (89) 1 1⁄2 (38) 1 1⁄2 (38) 1 5⁄8 (41) 1 5⁄8 (41) 1 1⁄4 (32) 1 1⁄4 (32) 27⁄16 (62) 3 (76) 1 13⁄16 (46) 1 13⁄16 (46) 9 ⁄16 (14) 9 ⁄16 (14) — — 115⁄16 (49) 115⁄16 (49) — — 2 (51) 2 (51) 3 B ⁄2 (13) ⁄2 (13) 9 ⁄16 (14) 9 ⁄16 (14) 1 Mounting Dimensions Outline Dimensions K L 3 1 3 1 ⁄4 (19) ⁄4 (19) 1 ⁄2 (13) 1 ⁄2 (13) ⁄8 (3) ⁄8 (3) 1 ⁄8 (3) 1 ⁄8 (3) NEMA & General Purpose Control Mounting Dimensions Outline Dimensions Amp Rating Reset Dimensions ⁄16 (5) ⁄16 (5) ⁄8 (3) 1 ⁄8 (3) 3 1 Mtg Screw G Max Wire Size Approx Ship Wt Ref Lbs (Kg) Dwg #10 #10 #10 #10 8 2 00 250 MCM 3 (1) 3 (1) 4 (2) 5 (2) D54791 D54823 D51868 D52038 Note: Dimensions for reference, not for construction. Dimensions in inches (mm). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-109 Lighting & Heating Contactors Electrically Held, Class LE Dimensions Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 NEMA & General Purpose Control CONTROL PRODUCTS 16 Figure 1 Open Type Lighting and Heating Contactors Outline Dimensions Mounting Dimensions Contact Rating Amps 20–30 20–30 20 Poles 2 3 4 Figure 2 2 1 A 3.36 3.97 3.62 B 2 2.25 2.87 B1 — — — B2 — — — C 2.69 2.88 2.88 C1 — — — D 1.63 3.13 3.13 D1 — 3.25 3.25 E 1.63 1.81 1.78 20 20 8 12 3 3 3.62 3.62 — — 3.71 — — 4.55 2.88 2.88 2.97 2.97 3.13 3.13 3.25 3.25 1.78 1.78 60 30–60 30–60 100 200 300 400 3 6 9–12 3 3 3 3 2 4 4 6 5 5 5 4.06 3.87 5.25 5.19 6.77 8.27 8.43 2.88 6.15 18.62 4.00 4.72 5.71 6.3 — — — — 5.91 6.89 7.48 — — — — — — — 3.06 3.06 3.31 4.75 7.09 8.54 9.29 — — — — — — — 3.13 3.18 4.62 4.63 5.12 7.09 7.09 3.25 — — 4.37 3.94 4.72 5.12 2.25 — 18.00 2.88 — — — Note: Dimensions for reference, not for construction. Dimensions in inches (mm). 16-110 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Mounting Screw #10 #10 #10 #10 #10 #10 #10 0.281 #10 0.28 0.35 0.35 Lighting & Heating Contactors Mechanically / Magnetically Held Lighting Contractors, Class CLM Dimensions CLM Contactor, 20 Amp Figure 1 Figure 2 Figure 3 G A B C D 16 F E CONTROL PRODUCTS Open Type Lighting and Heating Contactors Class Amp Rating Number of Poles A B C D E F G 1 1 2 2 2 2 2 2 3 30 30 60 60 100 100 200 200 30, 60 2–4 5 2, 3 4, 5 2, 3 4, 5 2, 3 4, 5 6-12 3.31 (84) 4.19 (106) 3.31 (84) 5.06 (129) 4.62 (117) 7.25 (184) 4.62 (117) 7.25 (184) 18.62 1.65 (42) 2.09 (53) 1.65 (42) 2.53 (64) 2.31 (59) 3.62 (92) 2.31 (59) 3.62 (92) 0.312 3.95 (100) 3.95 (100) 3.95 (100) 3.95 (100) 6.00 (152) 6.00 (152) 6.00 (152) 6.00 (152) 4.62 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 6.62 (168) 6.62 (168) 6.62 (168) 6.62 (168) 5.25 0.23 (6) 0.23 (6) 0.23 (6) 0.23 (6) 0.38 (10) 0.38 (10) 0.38 (10) 0.38 (10) 0.312 4.61 (117) 4.61 (117) 4.94 (125) 4.94 (125) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 4.98 1.50 (38) 1.50 (38) 1.50 (38) 1.50 (38) 1.88 (48) 1.88 (48) 1.88 (48) 1.88 (48) 18.00 Note: Dimensions for reference, not for construction. Dimensions in inches (mm). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-111 NEMA & General Purpose Control CLM Figure Number Lighting Control Mechanically Latched 300 and 400 Amps, Class CLM CLM Contactors 400 Amp NEMA & General Purpose Control CONTROL PRODUCTS 16 CLM Contactors 300 Amp Note: Dimensions for reference, not for construction. Dimensions in inches (mm). 16-112 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Dimensions Industrial Control Power Transformers Class MT Dimensions Top View Side View Dimension “C” does not include the added height required for secondary fuse clips—0.50 in. (13 mm) maximum for type “K” clips. The Primary Fuse Kit, when installed, will add a maximum of 0.69 in. (18 mm) to the transformer “A” dimension and 1.94 in. (49 mm) to the “C” dimension. A 2-pole Primary Class CC Fuse Block Kit is available for field installation. See page 16-74 for details. Catalog Number KCCFPX2R Note: Dimensions for reference, not for construction. Dimensions in inches (mm). Class MT Approximate Dimensions Inches (mm) VA Rating 50 75 100 150 300 500 750 1000 1500 2000 3000 5000 B 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 3.38 (86) 3.00 (76) 3.38 (86) 3.38 (86) 3.38 (86) 3.38 (86) 3.38 (86) 3.38 (86) 3.75 (95) 3.38 (86) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 5.25 (133) 4.50 (114) 4.50 (114) 4.50 (114) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 6.75 (171) 5.25 (133) 6.38 (162) 6.38 (162) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 9.00 (229) 9.00 (229) 9.00 (229) 9.00 (229) 9.00 (229) 9.00 (229) 9.00 (229) C 2.56 (65) 2.56 (65) 3.00 (76) 2.56 (65) 2.88 (73) 2.56 (65) 2.88 (73) 2.88 (73) 2.88 (73) 2.88 (73) 2.88 (73) 2.88 (73) 3.19 (81) 3.19 (81) 3.19 (81) 3.19 (81) 3.19 (81) 3.19 (81) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 3.81 (97) 4.75 (121) 3.81 (97) 3.81 (97) 3.81 (97) 4.75 (121) 4.44 (113) 4.75 (121) 4.75 (121) 4.75 (121) 4.75 (121) 4.44 (113) 4.75 (121) 4.75 (121) 4.75 (121) 5.75 (146) 4.44 (113) 5.38 (137) 5.38 (137) 5.69 (144) 5.69 (144) 5.69 (144) 5.69 (144) 5.69 (144) 7.31 (186) 7.56 (192) 7.56 (192) 7.56 (192) 7.56 (192) 10.19 (259) 10.56 (268) D 2.00 (51) 2.13 (54) 2.56 (65) 2.25 (57) 2.44 (62) 2.50 (64) 2.38 (60) 2.38 (60) 2.50 (64) 2.38 (60) 2.69 (68) 2.88 (73) 2.50 (64) 3.06 (78) 2.88 (73) 3.06 (78) 3.25 (83) 3.25 (83) 2.88 (73) 2.50 (64) 2.75 (70) 2.75 (70) 3.00 (76) 2.88 (73) 3.25 (83) 3.19 (81) 3.75 (95) 4.38 (111) 3.25 (83) 3.75 (95) 3.63 (92) 3.88 (98) 3.75 (95) 4.38 (111) 3.75 (95) 4.13 (105) 4.75 (121) 4.25 (108) 4.75 (121) 4.63 (117) 5.25 (133) 6.13 (156) 5.75 (146) 5.75 (146) 5.75 (146) 4.13 (105) 5.50 (140) 4.50 (114) 4.50 (114) 3.56 (90) 4.44 (113) 5.25 (133) 4.44 (113) 5.25 (133) 4.56 (116) 4.04 (103) 4.63 (117) 5.25 (133) 7.50 (190) 6.50 (165) 8.25 (210) E 2.50 (64) 2.50 (64) 2.50 (64) 2.50 (64) 2.81 (71) 2.50 (64) 2.81 (71) 2.81 (71) 2.81 (71) 2.81 (71) 2.81 (71) 2.81 (71) 3.13 (79) 3.13 (79) 3.13 (79) 3.13 (79) 3.13 (79) 3.13 (79) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 4.38 (111) 3.75 (95) 3.75 (95) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 6.06 (154) 4.38 (111) 5.19 (132) 5.19 (132) 6.06 (154) 6.06 (154) 6.06 (154) 6.06 (154) 6.06 (154) 6.50 (165) 6.50 (165) 6.50 (165) 6.50 (165) 7.20 (183) 6.50 (165) 6.50 (165) Mounting Slots 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 5/16 (8) X 11/16 (17) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 13/64 (5) X 3/8 (10) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 9/16 (14) 9/32 (7) X 13/32 (10) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 9/32 (7) X 9/16 (14) 9/32 (7) X 9/16 (14) 9/32 (7) X 9/16 (14) 9/32 (7) X 9/16 (14) 9/32 (7) X 9/16 (14) 9/32 (7) X 9/16 (14) 7/16 (11) X 3/4 (19) 7/16 (11) X 3/4 (19) 7/16 (11) X 3/4 (19) 7/16 (11) X 3/4 (19) 7/16 (11) X 3/4 (19) 7/16 (11) X 3/4 (19) Ship Wt Lbs (Kg) 2.6 (1) 2.8 (1) 3.5 (2) 3.4 (2) 4.0 (2) 3.5 (2) 4.3 (2) 4.5 (2) 4.8 (2) 4.2 (2) 4.9 (2) 6.0 (3) 5.9 (3) 6.6 (3) 6.7 (3) 7.4 (3) 7.7 (4) 7.9 (4) 8.8 (4) 8.5 (4) 9.4 (4) 9.0 (4) 10.6 (5) 10.0 (5) 11.1 (5) 9.7 (4) 13.9 (6) 14.7 (7) 11.3 (5) 13.6 (6) 11.7 (5) 15.5 (7) 13.6 (6) 15.6 (7) 16.5 (8) 16.8 (8) 18.6 (8) 19.2 (9) 21.0 (9) 21.5 (10) 21.5 (10) 23.4 (11) 28.1 (13) 30.0 (14) 28.0 (13) 30.5 (14) 28.1 (13) 30.0 (14) 29.2 (13) 30.0 (14) 33.5 (15) 33.5 (15) 38.0 (17) 42.5 (19) 42.5 (19) 53.0 (24) 63.7 (29) 63.7 (29) 140.0 (64) 102.0 (46) 102.0 (46) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-113 NEMA & General Purpose Control 350 A 3.00 (76) 3.13 (79) 3.00 (76) 3.25 (83) 4.00 (102) 3.50 (89) 3.38 (86) 3.13 (79) 3.50 (89) 3.38 (86) 3.69 (94) 3.88 (98) 3.63 (92) 4.63 (117) 4.00 (102) 4.19 (106) 4.25 (108) 4.38 (111) 4.44 (113) 4.00 (102) 4.25 (108) 4.25 (108) 4.50 (114) 4.38 (111) 4.75 (121) 4.75 (121) 5.25 (133) 5.86 (149) 4.75 (121) 5.25 (133) 5.13 (130) 5.13 (130) 5.25 (133) 8.25 (149) 5.00 (127) 5.38 (137) 5.63 (143) 5.50 (140) 6.00 (152) 5.88 (149) 6.86 (175) 7.00 (178) 7.00 (178) 7.38 (187) 7.00 (178) 5.63 (143) 7.86 (200) 7.13 (181) 7.50 (191) 6.75 (171) 7.50 (191) 8.25 (210) 7.00 (178) 8.25 (210) 7.56 (192) 7.50 (191) 8.00 (203) 8.63 (219) 10.0 (254) 10.50 (267) 13.50 (343) CONTROL PRODUCTS 250 Letters A, B, C, D, E, F, I, M G H J L A, B, C, D, E, F, I, M G H J A, B, C, D, E, F, I, M G H J L A, B, C, D, E, F, I, M G H J L A, B, C, D, E, F, I, M G H J A, B, C, D, E, F, I, M G H J L A, B, C, D, E, F, I, M G H J A, B, C, D, E, F, I, M G H J L A, B, C, D, E, F, I, M G H J L A, B, E, F, I G H L A, E, I G H A, I G H A, I G H A, I G H A G H 16 200 Approx Voltage Industrial Control Power Transformers Class MTG Dimensions Top View Dimension “C” does not include the added height required for secondary fuse clips—0.50 in. (13 mm) maximum for type “K” clips. Side View The Primary Fuse Kit, when installed, will add a maximum of 0.69 in. (18 mm) to the transformer “A” dimension and 1.94 in. (49 mm) to the “C” dimension. Note: Dimensions for reference, not for construction. Dimensions in inches (mm). Class MTG Approximate Dimensions Inches (mm) VA Rating 50 75 100 16 200 CONTROL PRODUCTS 150 250 300 NEMA & General Purpose Control 350 500 750 1000 1500 2000 3000 5000 16-114 Voltage Letters A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C, P E, I J A B, C J A A A A A 3.38 (86) 3.25 (83) 3.38 (86) 3.25 (83) 3.50 (89) 3.25 (83) 3.50 (89) 3.63 (92) 3.63 (92) 3.63 (92) 3.63 (92) 4.38 (111) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.50 (114) 4.38 (111) 4.50 (114) 5.00 (127) 4.38 (111) 4.75 (121) 4.75 (121) 5.50 (140) 5.13 (130) 5.13 (130) 5.13 (130) 5.38 (137) 5.00 (127) 5.00 (127) 5.00 (127) 5.50 (140) 6.00 (152) 5.50 (140) 6.00 (152) 7.25 (184) 7.38 (187) 7.00 (178) 7.38 (187) 5.56 (141) 5.31 (135) 5.56 (141) 7.00 (178) 6.13 (156) 6.44 (164) 6.25 (159) 8.75 (222) B 3.00 (76) 3.00 (76) 3.00 (76) 3.38 (86) 3.38 (86) 3.38 (86) 3.38 (86) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 5.25 (133) 6.38 (162) 6.38 (162) 6.38 (162) 6.38 (162) 6.75 (171) 6.75 (171) 9.00 (229) 9.00 (229) C 3.00 (76) 3.00 (76) 3.00 (76) 3.25 (83) 3.25 (83) 3.25 (83) 3.25 (83) 3.50 (89) 3.50 (89) 3.50 (89) 3.50 (89) 3.50 (89) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.00 (102) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 4.50 (114) 7.19 (183) 5.31 (135) 7.19 (183) 7.19 (183) 7.50 (191) 7.50 (191) 9.38 (238) 9.38 (238) D 2.50 (64) 2.25 (57) 2.50 (64) 2.25 (57) 2.50 (64) 2.25 (57) 2.50 (64) 2.50 (64) 2.50 (64) 2.50 (64) 2.50 (64) 3.19 (81) 2.50 (64) 2.50 (64) 2.50 (64) 2.81 (71) 3.19 (81) 2.81 (71) 3.19 (81) 3.50 (89) 3.19 (81) 3.19 (81) 3.19 (81) 4.06 (103) 3.75 (95) 3.75 (95) 3.75 (95) 4.25 (108) 3.75 (95) 3.75 (95) 3.75 (95) 4.25 (108) 4.75 (121) 4.25 (108) 4.75 (121) 6.00 (153) 5.75 (146) 5.38 (137) 5.75 (146) 4.38 (111) 4.06 (103) 4.31 (110) 5.75 (146) 4.94 (125) 5.25 (133) 4.56 (116) 6.50 (165) E 2.50 (64) 2.50 (64) 2.50 (64) 2.81 (71) 2.81 (71) 2.81 (71) 2.81 (71) 3.13 (79) 3.13 (79) 3.13 (79) 3.13 (79) 3.13 (79) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 3.75 (95) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) 6.13 (156) 6.13 (156) 6.50 (165) 6.50 (165) Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Mounting Slots 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 13/64 (5) X 15/32 (12) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 5/16 (8) X 11/16 (17) 9/32 (7) X 9/16 (14) 9/32 (7) X 9/16 (14) 7/16 (11) X 3/4 (19) 7/16 (11) X 3/4 (19) Approx Ship Wt Lbs (Kg) 3.5 (2) 3.4 (2) 3.5 (2) 4.2 (2) 4.8 (2) 4.2 (2) 4.8 (2) 5.9 (3) 5.9 (3) 5.9 (3) 5.9 (3) 7.9 (4) 8.5 (4) 8.5 (4) 8.5 (4) 8.5 (4) 10.6 (5) 10.0 (5) 10.6 (5) 10.6 (5) 11.3 (5) 11.3 (5) 11.3 (5) 15.2 (7) 13.2 (6) 13.2 (6) 13.2 (6) 16.8 (8) 14.9 (7) 14.9 (7) 14.9 (7) 19.2 (9) 21.0 (9) 19.2 (9) 21.0 (9) 27.0 (12) 30.0 (14) 28.1 (13) 30.0 (14) 30.0 (14) 26.3 (12) 26.3 (12) 40.0 (18) 40.0 (18) 45.1 (21) 65.2 (30) 104.8 (48) Heavy Duty Motor Starters & Contactors Enclosed, Class 14, 40 Figure 2 Figure 1 K3 K2 K1 K3 K2 K2 Figure 3 K3 K1 K2 K2 K1 Figure 5 Figure 4 K3 K2 K1 K3 K2 K3 K3 K2 K2 Dimensions D A K2 K2 D A K3 K3 D A E B G D A E B G G C K2 K2 C K3 E B G K3 K1 K3 E B C View is typical for bottom and top K3 K1 K2 C K3 K1 K2 NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)햲 w/o CPT w/o CPT (100VA) (300VA) (300VA) (300VA) Figure 1 2 3 4 5 5 B C D E G K1 K2 K3 K4 K5 1031⁄32 (279) 1317⁄32 (344) 191⁄8 (486) 247⁄8 (632) 40 (1016) 48 (1219) 613⁄32 (163) 731⁄32 (202) 113⁄8 (289) 133⁄8 (340) 20 (508) 20 (508) 51⁄32 (128) 63⁄8 (162) 711⁄16 (195) 81⁄8 (206) 11 (279) 121⁄2 (317) 8 7⁄32 (209) 101⁄4 (260) 155⁄8 (397) 213⁄4 (552) 375⁄8 (956) 453⁄16 (1148) 45⁄8 (117) 6 (152) 81⁄4 (210) 9 (229) 151⁄4 (387) 10 (254) 1 1 1 3 ⁄4–1 1–11⁄4 11⁄2–2 2–21⁄2 1 ⁄2–3⁄4 1 ⁄2–3⁄4 — — — — 11⁄4–11⁄2 11⁄4–11⁄2 — — — — 2–3 2–21⁄2 10 (5) 15 (7) 26 (12) 37 (17) 135 (36) 150 (44) K3 K4 K5 Approx Ship Wt Lbs (Kg) Ref Dwg — — — — — — 26 (12) 26 (12) 37 (17) ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 1 ⁄4 ⁄2 1 ⁄2–3⁄4 1 ⁄2–3⁄4 1 ⁄2–3⁄4 2–3 2–21⁄2 ⁄2–3⁄4 3 ⁄4–1 1–11⁄4 11⁄4–11⁄2 11⁄4–11⁄2 11⁄4–11⁄2 D68870 D68870 D68870 D68870 D65608 D65608 NEMA 1 General Purpose Enclosure (Extra wide for use with CPT)햲 Size Max CPT Size 00–13⁄4 (200VA) 2–21⁄2 (200VA) 3–31⁄2 (250VA) Outline Dimensions Figure A 3 3 4 191⁄8 (486) 191⁄8 (486) 241⁄8 (632) Mounting Dimensions Mounting Screw Conduit Size B C D E G K1 K2 113⁄8 (289) 113⁄8 (289) 133⁄8 (340) 711⁄16 (195) 711⁄16 (195) 81⁄8 (206) 155⁄8 (397) 155⁄8 (397) 213⁄4 (552) 81⁄4 (210) 81⁄4 (210) 9 (229) 1 1 1 1 1–11⁄4 11⁄2–2 1–11⁄4 11⁄2–2 1–11⁄4–11⁄2 2–21⁄2 Note: Dimensions in inches (millimeters). Dimensions for reference, not for construction. Contact Sales Office for dimensions not listed. ⁄4 ⁄4 1 ⁄4 ⁄2–3⁄4 ⁄2–3⁄4 1 ⁄2–3⁄4 D68870 D68870 D68870 햲 Clamshell enclosure Size 00 - 4; Standard width and Extra wide. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-115 NEMA & General Purpose Control A Mounting Dimensions CONTROL PRODUCTS 00–13⁄4 2–21⁄2 3–31⁄2 4 5 6 Mounting Screw Conduit Size Approx Ship Wt Lbs (Kg) Ref Dwg Outline Dimensions 16 Size Max CPT Size Heavy Duty Motor Starters & Contactors Enclosed, Class 14, 40 Dimensions Figure 1 Figure 2 Figure 3 Figure 4 G G D A T R T R ESE ESE B C MAX K2 G E K1 Typical view top and bottom K3 NEMA 4X Fiberglass Enclosures (Standard width for use with or without CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E Mtg Screw Conduit Size G K1 K2 0–21⁄2 3–4 1 1 14.620 (371) 11.880 (302) 23.780 (604) 23.780 (604) 6.890 (175) 6.890 (175) 1⁄4 15.000 (381) 9.750 (248) 24.125 (612.7) 21.250 (539.7) 1⁄4 — — — — K3 Approx Ship Wt Lbs (Kg) Ref Dwg — — 11 (4.9) 28 (12.7) 24-139-861-001 24-139-861-003 NEMA 7/9/3/4 Hazardous Location Enclosure (Standard width for use with or without CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E 0–13⁄4 w/o CPT 2–21⁄2 (0–13⁄4 w/ CPT) 3–31⁄2 w/o CPT 4 5 2 2 2 2 2 15.250 (387) 17.750 (451) 17.750 (451) 28.688 (729) 48.875 (1038) 10.000 (254) 10.375 (264) 10.375 (264) 11.750 (298) 14 7/8 (377) 8.500 (216) 10.625 (270) 10.625 (270) 18.375 (467) 29 (373) 10.688 (272) 14.688 (373) 14.688 (373) 17.750 (451) 22.875 (581) 9.125 (132) 13.250 (337) 13.250 (337) 15.750 (400) 213⁄5 (533) Mtg Screw Conduit Size G K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg ⁄ ⁄ 3⁄4 3⁄4 3⁄4 33 (14.9) 60 (27.0) 60 (27.0) 140 (63.5) 352 (159) K3 Approx Ship Wt Lbs (Kg) Ref Dwg 34 ⁄ ⁄ 60 (27.0) 140 (63.5) K3 Approx Ship Wt Lbs (Kg) Ref Dwg — — — — — — 12 (5) 18 (8) 49 (22) Mtg Screw Conduit Size G K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg ⁄ ⁄4 1⁄4 3⁄8 3 ⁄8 3⁄8 — — — — — — — — — — — — Mtg Screw Conduit Size G K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg ⁄ ⁄ 1⁄4 — — — — — — 17.5 (8) 36 (16) 67 (30) Mtg Screw Conduit Size G K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg ⁄ ⁄ 1⁄4 5⁄16 3⁄8 3⁄8 — — — — — — ⁄ ⁄ 3⁄8 1⁄2 5⁄8 38 38 ⁄ ⁄ 1⁄2 1⁄2 1⁄2 12 12 11⁄2 2 2 3 3 34 34 24-139-865-002 24-139-865-003 24-139-865-003 24-139-865-004 24-139-865-006 CONTROL PRODUCTS 16 NEMA 7/9/3/4 Hazardous Location Enclosure (Extra wide for use with CPT) Size 햲 0–21⁄2 3–31⁄2 Figure Outline Dimensions A B C Mounting Dimensions D E Mtg Screw Conduit Size G K1 K2 2 2 17.750 (451) 14.688 (373) 28.688 (729) 17.750 (451) 10.375 (264) 11.750 (298) 10.625 (270) 13.250 (337) 18.375 (467) 15.750 (400) 38 12 12 12 ⁄ ⁄ ⁄ ⁄ 2 3 34 24-139-865-003 24-139-865-004 NEMA 12/3/3R Industrial Use Enclosure (Standard width for use without CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E 0–13⁄4 2–21⁄2 3–4 3 3 3 13.000 (330) 7.750 (197) 16.000 (406) 8.125 (206) 26.000 (660) 13.125 (333) 5.438 (138) 6.063 (154) 7.563 (192) 12.250 (311) 5.000 (127) 15.250 (387) 5.000 (127) 25.250 (641) 10.000 (254) Mtg Screw Conduit Size G K1 K2 ⁄ ⁄ ⁄4 14 14 1 — — — D41547 D41547 D41552 NEMA & General Purpose Control NEMA 12/3/3R Industrial Use Enclosure (Extra wide for use with CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E 0–13⁄4 2–2 1⁄2 3–3 1⁄2 4 5 6 3 3 3 3 4 4 13.000 (330) 16.000 (406) 26.000 (660) 29.063 (738) 40.000 (1016) 48.000 (1219) 5.375 (137) 6.125 (156) 7.563 (192) 9.250 (235) 11.000 (279) 12.500 (317) 12.250 (311) 15.250 (387) 25.250 (641) 27.563 (700) 41.000 (1041) 49.000 (1244) 12.625 (321) 13.250 (337) 13.125 (333) 23.188 (589) 20.000 (508) 20.000 (508) 10.000 (254) 11.000 (279) 10.000 (254) 20.000 (508) 10.000 (254) 10.000 (254) 14 1 — — — — — — 30 (14) 33 (15) 49 (22) 64 (29) D17150 D17150 D41552 D17150 D65608007 D65608009 NEMA 4/4X Stainless Steel Enclosure (Standard width for use without CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E 0–13⁄4 2–21⁄2 3–4 3 3 3 13.000 (330) 7.750 (197) 16.000 (406) 8.125 (206) 26.000 (660) 13.125 (333) 5.438 (138) 6.063 (154) 7.563 (192) 12.250 (311) 5.000 (127) 15.250 (387) 5.000 (127) 25.250 (641) 10.000 (254) 14 14 — — — D41546 D41546 D41551 NEMA 4/4X Stainless Steel Enclosure (Extra wide for use with CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E 0–13⁄4 2–21⁄2 3–31⁄2 4 5 (Painted) 6 (Painted) 3 3 3 3 4 4 13.000 (330) 16.000 (406) 26.000 (660) 29.000 (737) 40.000 (1016) 48.000 (1219) 5.375 (137) 6.000 (152) 7.563 (192) 9.250 (235) 11.000 (279) 12.500 (317) 12.250 (311) 15.250 (387) 25.250 (641) 27.500 (699) 41.000 (1041) 49.000 (1244) 12.625 (321) 13.250 (337) 13.125 (333) 23.188 (589) 20.000 (508) 20.000 (508) Note: Dimensions in inches (millimeters). Dimensions for reference, not for construction. Contact Sales Office for dimensions not listed. 16-116 10.000 (254) 11.000 (279) 10.000 (254) 20.000 (508) 10.000 (254) 10.000 (254) 14 14 — — — — — — for addition of CPT only on size 2 1⁄2. If pilot devices are needed, use size 3-31⁄2 enclosure. 햲 Used Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog — — — — — — 30 (14) 33 (15) 67 (30) 64 (29) D41917 D42935 D41551 D43292 D65608007 D65608009 Combination Heavy Duty Starters Enclosed, Class 17, 18 Dimensions Figure 1 Figure 2 H 7.0 Typical view top and bottom 3.0 3.0 H Typical view top and bottom 1/2 1 X 1 1/4 X 3/4 Knockout Knockout 6.00 (156) B 1/2 X 3/4 1 1/2 X 2 Knockout 1 1/2 X 2 Knockout Knockout C B E C D GA GA Mounting Holes for 1/4" Screws Qty. 3 E Mounting Holes for 1/4" Screws Qty. 4 D E D Figure 4 Figure 3 8.5 3.5 3.5 H Typical view top and bottom 1/2 X 3/4 1 1/2 X 2 Knockout 1 1/2 X 2 Knockout Knockout 16 B D E C CONTROL PRODUCTS G A D NEMA & General Purpose Control E Mounting Holes for 1/4" Screws Qty. 4 NEMA 1 Standard Width 0–6 Mounting Dimensions Size Figure A B C D E G H Approx Ship Wt Lbs (Kg) Ref Dwg 0–2 21⁄2, 3 31⁄2, 4 5 6 1 2 3 4 4 24 (610) 24 (610) 36 (914) 72.156 (1833) 79.125 (2010) 11 (279) 20 (508) 24 (610) 20 (508) 22 (559) 8 (203) 8 (203) 8 (203) 11.031 (280) 13 (330) 6.125 (156) 15.00 (381) 14.00 (356) 71 (1803) 78 (1981) 2.125 (54) 2.125 (54) 5.00 (127) 16 (406) 18 (457) 21.00 (533) 21.00 (533) 33.50 (851) — — 3.50 (90) 3.50 (90) 5.00 (127) — — 35 (16) 48 (22) 101 (46) 250 (113) 275 (125) D68774001 D68774002 D68774003 D56032005 D56032006 Ref Dwg D68774002 D68774003 Outline Dimensions NEMA 1 Extra Wide 0–3 Mounting Dimensions Size Figure A B C D E G H Approx Ship Wt Lbs (Kg) 0–2 21⁄2, 3 2 3 24 (610) 36 (914) 20 (508) 24 (610) 8 (203) 8 (203) 15.00 (381) 14.00 (356) 2.125 (54) 5.00 (127) 21.00 (533) 33.50 (851) 3.50 (90) 5.00 (127) 48 (22) 101 (46) Outline Dimensions Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-117 Combination Heavy Duty Starters Enclosed, Class 17, 18 Dimensions Figure 2 Figure 1 5.50 (140) Figure 3 B B C E B D E C D C H G E Mounting Holes for 1/4" Screws Qty. 4 Mounting Holes for 1/4" Screws Qty. 3 D AGH AGH A Mounting Holes for 1/4" Screws Qty. 4 Figure 5 Figure 4 C D CONTROL PRODUCTS 16 A Mounting Holes for No. 10 Screws Qty. 4 E B Mounting Holes for G 3/8" screw. Qty. 4 NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Standard Width 0–6 Mounting Dimensions Size Figure A B C D E G H Approx Ship Wt Lbs (Kg) 0–2 21⁄2, 3 31⁄2, 4 5 (Painted) 6 (Painted) 1 2 3 4 4 24 (610) 24 (610) 36 (914) 72.156 (1833) 79.125 (2010) 11 (279) 20 (508) 24 (610) 20 (508) 22 (559) 8 (203) 8 (203) 8 (203) 11.031 (280) 13 (330) 6.00 (152) 15.00 (381) 12 (305) 71 (1830) 78 (1981) 2.50 (64) 2.50 (64) 6.00 (152) 16 (406) 18 (457) 25.75 (654) 25.75 (654) 37.75 (959) — — 26.75 (680) 26.75 (680) 38.75 (984) — — 35 (16) 48 (22) 101 (46) 250 (113) 275 (125) Ref Dwg NEMA & General Purpose Control Outline Dimensions Ref Dwg D56033 D56033 D56033 D56032005 D56032006 NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Extra Wide 0–3 Mounting Dimensions Size Figure A B C D E G H Approx Ship Wt Lbs (Kg) 0–2 2 3 24 (610) 36 (914) 20 (508) 24 (610) 8 (203) 15.00 (381) 12.00 (305) 2.50 (64) 6.00 (152) 25.75 (654) 37.75 (959) 26.75 (654) 38.75 (984) 49 (22) 102 (46) D56033 D56033 Ref Dwg Outline Dimensions 21⁄2, 3 8 (203) NEMA 4X Fiberglass Standard Width 0–4 Mounting Dimensions Size Figure A B C D E G H Approx Ship Wt Lbs (Kg) 0–13⁄4 2–31⁄2 4 5 5 5 23.75 (603) 23.75 (603) 39.37 (1000) 14.62 (371) 23.75 (603) 29.52 (750) 7.12 (181) 8.50 (216) 12.20 (310) 24.09 (612) 24.06 (611) 40.94 (1040) 12.20 (310) 21.30 (541) 27.95 (710) — — — — — — 42 (19) 44 (20) 55 (25) Outline Dimensions Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed. 16-118 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Combination Heavy Duty Starters Enclosed, Class 18 Dimensions Figure 1 RESET OFF TRIP ON A D T R T R ESE ESE B G (Qty. 4) C MAX K2 K1 K3 E Typical view bottom and top 16 Outline Dimensions Mounting Dimensions Mounting Screw Conduit Size Size Figure A B C D E G K1 K2 K3 0–13⁄4 2–31⁄2 4 5 1 1 1 1 17.38 (441) 28.25 (718) 32.25 (819) 40.875 (1038) 14.69 (373) 17.75 (451) 20.00 (508) 22.875 (581) 10.38 (264) 11.19 (284) 11.50 (292) 14.875 (378) 10.63 (270) 18.38 (467) 22.50 (572) 29 (737) 13.25 (337) 15.75 (400) 17.75 (451) 21.75 (552) 3 3 2 21⁄2 21⁄2 3 1 ⁄8 3 ⁄8 5 ⁄8 5 ⁄8 ⁄4 3 ⁄4 3 ⁄4 1 ⁄2 ⁄2 1 ⁄2 1 ⁄2 3 ⁄4 Approx Ship Wt Lbs (Kg) Ref Dwg 60 (27) 160 (72) 250 (113) 360 (163) 24-139-865-003 24-139-865-004 24-139-865-005 — NEMA & General Purpose Control Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact Sales Office for dimensions not listed. CONTROL PRODUCTS NEMA 7 & 9, 3, 4 Standard Width 0–4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-119 Reversing Heavy Duty Starters & Contactors Enclosed, Class 22, 43 K1 K2 K3 Figure 4 Figure 3 Figure 2 Figure 1 K2 Dimensions K3 K1 G D A D D A T R ESE T R A ESE B G G E B E B C MAX K2 C C E K1 K3 K1 K3 K2 K1 K3 K2 CONTROL PRODUCTS 16 View is typical for bottom and top NEMA 1 General Purpose Enclosure (Standard width for use with and without CPT) Mounting Mounting Dimensions Screw Conduit Size Outline Dimensions Size Figure A 00–21⁄2 (200 VA) 3–4 (300 VA) 5 6 1 2 191⁄8 (486) 247⁄8 (632) B C D E G 113⁄8 (289) 133⁄8 (340) 711⁄16 (195) 81⁄8 (206) 155⁄8 (397) 213⁄4 (552) 81⁄4 (210) 9 (229) 1 K1 1 ⁄4 ⁄2–3⁄4 1 1 ⁄4 ⁄2–3⁄4 Contact Sales Office Contact Sales Office K2 K3 K4 Approx Ship Wt Lbs (Kg) 1–11⁄4 11⁄4–11⁄2 11⁄2–2 2–21⁄2 — — 30 (14) 52 (24) Ref Dwg D68870 D68870 NEMA & General Purpose Control NEMA 4/4X Stainless Steel Enclosure (with or without CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E Mtg Screw Conduit Size G K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg 0–13⁄4 2–21⁄2 3–31⁄2 (w/o CPT) 3–31⁄2 (w/ CPT) 4 5 (Painted) 6 (Painted) 3 3 3 13 (330) 16 (406) 251⁄16 (637) 125⁄8 (321) 131⁄4 (337) 173⁄16 (437) 53⁄8 (137) 6 (152) 73⁄8 (187) 121⁄4 (311) 151⁄4 (387) 245⁄16 (618) 10 (254) 11 (279) 14 (356) 14 ⁄ ⁄ 1⁄4 — — — — — — — — — 30 (14) 33 (15) 53 (24) D41917 D42935 D17423 3 29 (737) 233⁄16 (589) 91⁄4 (235) 271⁄2 (699) 20 (508) ⁄ — — — 64 (29) D43292 K3 Approx Ship Wt Lbs (Kg) Ref Dwg ⁄ ⁄ 140 150 14 5 16 Contact Sales Office Contact Sales Office NEMA 7/9/3/4 Hazardous Location Enclosure (with or without CPT) Size Figure Outline Dimensions A B C Mounting Dimensions D E Mtg Screw Conduit Size G K1 K2 0–21⁄2 3–4 4 4 281⁄4 (718) 321⁄4 (819) 91⁄4 (235) 99⁄16 (243) 183⁄8 (467) 221⁄2 (572) 12 12 12 12 161⁄4 (413) 181⁄4 (464) 153⁄4 (400) 173⁄4 (451) ⁄ ⁄ ⁄ ⁄ Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed. 16-120 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3 3 34 34 24-139-865-004 24-139-865-005 Reversing Heavy Duty Starters & Contactors Enclosed, Class 22, 43 Dimensions Figure 5 Figure 6 Figure 7 .188 5.00 12.50 10.00 1.20 48.00 45.75 2.38 .69 15.25 20.00 4-POINT MOUNTING FOR .31 SCREWS A 29.88 DOOR OPEN 90° .38 HOLE DIA. FOR PADLOCK A B C B 11.62 16.50 12.75 K3 7.25 K2 10.00 0 K1 0.50 2.71 A COMB. K.O.’s FOR 1.00, 1.25, 1.50, 2.00, OR 2.50 CONDUIT B COMB. K.O.’s FOR 1.00, 1.25, OR 1.50 CONDUIT C COMB. K.O.’s FOR 0.50 OR 0.75 CONDUIT View is typical for bottom and top 16 NEMA 12/3/3R Industrial Use Enclosure (with or without CPT) Figure Outline Dimensions A B C Mounting Dimensions D E 0–13⁄4 2–21⁄2 3–31⁄2 (w/o CPT) 3–31⁄2 (w/ CPT) 4 5 6 (300 VA CPT max.) 5 5 5 13 (330) 16 (406) 251⁄16 (637) 125⁄8 (321) 131⁄4 (337) 173⁄16 (437) 53⁄8 (137) 61⁄8 (156) 73⁄8 (187) 121⁄4 (311) 151⁄4 (387) 245⁄16 (618) 10 (254) 11 (279) 14 (356) 14 5 291⁄16 (738) 233⁄16 (589) 91⁄4 (235) 279⁄16 (700) 20 (508) 453⁄4 (1162) Contact Sales Office 1⁄4 10 (254) 7 48 (1219) 20 (508) 121⁄2 (318) Mtg Screw Conduit Size G K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg 14 ⁄ ⁄ ⁄ — — — — — — — — — 30 (14) 33 (15) 53 (24) D17150 D17150 D17150 5 16 ⁄ — — — 64 (29) D17150 — — — Mtg Screw Conduit Size G K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg — — 35 38 14 CONTROL PRODUCTS Size NEMA 4X Fiberglass Enclosure (with or without CPT) Figure Outline Dimensions A B C Mounting Dimensions D E 0–21⁄2 3–31⁄2 4 6 6 23.78 (604) 23.78 (604) 6.89 (175) 6.89 (175) 224⁄5 (579) 224⁄5 (579) 14.68 (373) 23.78 (604) 1⁄4 134⁄5 (351) 1⁄4 224⁄5 (579) Contact Sales Office — — — — Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-121 NEMA & General Purpose Control Size Combination Reversing Heavy Duty Starters Enclosed, Class 25, 26 Dimensions Figure 1 7.0 3.0 Figure 2 3.0 8.5 H H Typical view top and bottom 1/2 X 3/4 Knockout 1 1/2 X 2 Knockout 1 1/2 X 2 Knockout 1 1/2 X 2 Knockout B E C D Figure 3 3.5 3.5 Typical view top and bottom 1/2 X 3/4 1 Knockout 1 /2 X 2 Knockout B D E C G A GA Mounting Holes for 1/4" Screws Qty. 4 E E D Mounting Holes for 1/4" Screws Qty. 4 D Figure 4 Figure 5 Figure 6 B E C D RESET OFF TRIP ON A D T R T R ESE ESE AGH B Mounting Holes for 3/8" screws Qty. 4 CONTROL PRODUCTS 16 C MAX Mounting Holes for 1/4" Screws Qty. 4 K1 E K3 NEMA 1 Standard Width 0–6 Mounting Dimensions Size Figure A B C D E G H Approx Ship Wt Lbs (Kg) 0–21⁄2 3–4 5 (Painted) 6 (Painted) 1 2 3 3 24 (610) 36 (914) 72.156 (1833) 79.125 (2010) 20 (508) 24 (610) 20 (508) 22 (559) 8 (203) 8 (203) 11.031 (280) 13 (330) 15.00 (381) 14.00 (356) 71 (1803) 78 (1981) 2.125 (54) 5.00 (127) 16 (406) 18 (457) 21.00 (533) 33.50 (851) — — 3.50 (90) 5.00 (127) — — 60 (27) 121 (55) 250 (113) 275 (125) D68774002 D68774003 D56032005 D56032006 Ref Dwg D68774005 D68774006 D56032005 D56032006 Outline Dimensions NEMA & General Purpose Control Typical view top and bottom K2 Ref Dwg NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Standard Width 0–6 Mounting Dimensions Size Figure A B C D E G H Approx Ship Wt Lbs (Kg) 0–21⁄2 3–4 5 (Painted) 6 (Painted) 5 5 3 3 24 (610) 36 (914) 72.156 (1833) 79.125 (2010) 20 (508) 24 (610) 20 (508) 22 (559) 8 (203) 8 (203) 11.031 (280) 13 (330) 15.00 (381) 12 (305) 71 (1803) 78 (1981) 3.50 (90) 6.00 (152) 16 (406) 18 (457) 25.75 (654) 37.75 (959) — — 26.75 (654) 38.75 (984) — — 63 (29) 124 (56) 250 (113) 275 (125) Outline Dimensions NEMA 4X Fiberglass 0–4 Size Figure Outline Dimensions A B C Mounting Dimensions D E Mtg Screw Conduit Size G K1 K2 0–21⁄2 3–4 4 4 23.780 (604) 14.680 (373) 23.780 (604) 23.780 (604) 6.890 (175) 6.890 (175) 24.125 (612.7) 12.250 (311) 3⁄8 24.125 (612.7) 21.250 (539.7) 3⁄8 — — K3 Approx Ship Wt Lbs (Kg) Ref Dwg — — — — 18 (8) 28 (12.7) K3 Approx Ship Wt Lbs (Kg) Ref Dwg ⁄ 140 (63.5) 24-139-861-001 24-139-861-003 NEMA 7/9/3/4 Hazardous Location 0–4 Size Figure Outline Dimensions A B C Mounting Dimensions D E Mtg Screw Conduit Size G K1 K2 0–21⁄2 3–4 6 28.688 (729) 17.750 (451) 11.750 (298) 18.375 (467) 15.750. (400) 3⁄8 1⁄2 Contact Sales Office Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed. 16-122 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 3 34 24-139-865-004 Two Speed Heavy Duty Starters Enclosed, Class 30 Dimensions Figure 1 K2 K1 Figure 1a K2 K3 Figure 2 K3 K1 K1 K2 Figure 3 Figure 4 K3 D A D A D A E B G D A G G E B C K1 E B K2 C K3 G E B C K3 K1 K2 C K3 K1 K2 2 Speed 1 Winding NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT) Size Fig Outline Dimensions A B 0–1 3⁄4 w/o CPT 0–1 3⁄4 (200 VA) 2–2 1⁄2 3–3 1⁄2 1 1a 2 2 19 1⁄8 24 7⁄8 16 18.31 (486) (632) (406) (465) 11 3⁄8 13 3⁄8 17.13 21.19 Mounting Dimensions D E C (289) (340) (435) (538) 7 11⁄16 8 1⁄8 7.63 7.38 (195) (206) (194) (187) 15 5⁄8 21 3⁄4 15.25 17.56 (397) (552) (387) (446) Mtg Screw G Conduit Size K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg 8 1⁄4 (210) 9 (229) 14 (355) 18 (457) 14 ⁄ 1⁄4 1⁄4 1⁄4 12 34 ⁄–⁄ 1⁄2–3⁄4 1⁄2–3⁄4 1 1⁄4 –1 1⁄2 1–1 1⁄4 1 1⁄4 –1 1⁄2 1 1⁄4 –1 1⁄2 1⁄2 –3⁄4 1 1⁄2–2 2–2 1⁄2 1 1⁄4 –1 1⁄2 1 1⁄2–2 26 52 39 60 (12) (24) (20) (27) D68870 D68870 D42932001 D72956002 10 14 14 14 20 20 (254) (355) (355) (355) (508) (508) 14 ⁄ ⁄ 1⁄4 1⁄4 5⁄16 5⁄16 — — — — — — — — — — — — — — — — — — 34 47 47 55 61 61 (15) (21) (21) (25) (28) (28) D41917000 10 14 14 14 20 (254) (355) (355) (355) (508) 14 NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT) w/o CPT w/ CPT w/o CPT w/ CPT 13 16 16 25 1⁄16 29 29 (330) (406) (406) (637) (737) (737) 12 5⁄8 17 1⁄8 17 1⁄8 17 3⁄16 23 3⁄16 23 3⁄16 (321) (435) (435) (437) (589) (589) 5 3⁄8 7 5⁄8 7 5⁄8 7 3⁄8 9 1⁄4 9 1⁄4 (137) (194) (194) (187) (235) (235) 12 1⁄4 15 1⁄4 15 1⁄4 24 5⁄16 27 1⁄2 27 1⁄2 (311) (387) (387) (618) (699) (699) 14 D43292001 D43292001 NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT) 0–1 3⁄4 0–1 3⁄4 2–2 1⁄2 2–2 1⁄2 3–4 w/o CPT w/ CPT w/o CPT w/ CPT 3 3 3 3 3 13 16 16 25 1⁄16 29 (330) (406) (406) (637) (737) 12 5⁄8 17 1⁄8 17 1⁄8 17 3⁄16 23 3⁄16 (321) (435) (435) (437) (589) 5 3⁄8 7 5⁄8 7 5⁄8 7 3⁄8 9 1⁄4 (137) (194) (194) (187) (235) 12 1⁄4 15 1⁄4 15 1⁄4 24 5⁄16 27 1⁄2 (311) (387) (387) (618) (699) ⁄ ⁄ 1⁄4 1⁄4 5⁄16 — — — — — — — — — — — — — — — 34 47 47 55 61 (15) (21) (21) (25) (28) ⁄ — — — — — — 28 (13) 14 D17150010 D17150010 CONTROL PRODUCTS 3 3 3 3 3 3 16 0–1 3⁄4 0–1 3⁄4 2–2 1⁄2 2–2 1⁄2 3–3 1⁄2 4 D19673000 NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT) 0–2 1⁄2 3–4 4 4 23.780 (604) 39.37 (1000) 23.780 (604) 29.53 (750) 6.890 (175) 12.60 (320) — — — — 14 — 24139861003 24139861004 NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT) Size Fig Outline Dimensions A B 0–2 1⁄2 w/o CPT 0–2 1⁄2 (200 VA) 3–4 w/o CPT 1 1a 1a 19 1⁄8 24 7⁄8 24 7⁄8 (486) (632) (632) 11 3⁄8 13 3⁄8 13 3⁄8 (289) (340) (340) C Mounting Dimensions D E 7 11⁄16 (195) 8 1⁄8 (206) 8 1⁄8 (206) 15 5⁄8 21 3⁄4 21 3⁄4 (397) (552) (552) 8 1⁄4 (210) 9 (229) 9 (229) Mtg Screw G Conduit Size K1 K2 K3 Approx Ship Wt Lbs (Kg) Ref Dwg 14 ⁄ 1⁄4 1⁄4 12 34 ⁄–⁄ 1⁄2–3⁄4 1⁄2–3⁄4 1–1 1⁄4 1 1⁄4–1 1⁄2 1 1⁄4 –1 1⁄2 1 1⁄2–2 2–2 1⁄2 2–2 1⁄2 30 52 52 (14) (24) (24) D68870 D68870 D68870 ⁄ ⁄ ⁄4 1⁄4 1⁄4 5⁄16 5⁄16 — — — — — — — — — — — — — — — — — — — — — 34 41 41 41 55 61 61 (15) (19) (19) (19) (25) (28) (28) D43292001 D43292001 NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT) 0–1 3⁄4 w/o CPT 0–1 3⁄4 w/ CPT 2–2 1⁄2 w/o CPT 2–2 1⁄2 w/ CPT 3–3 1⁄2 w/o CPT 3–3 1⁄2 w/ CPT 4 3 3 3 3 3 3 3 13 16 16 16 25 1⁄16 29 29 (330) (406) (406) (406) (637) (737) (737) 12 5⁄8 17 1⁄8 13 1⁄4 17 1⁄8 17 3⁄16 23 3⁄16 23 3⁄16 (321) (435) (337) (435) (187) (589) (589) 5 3⁄8 7 5⁄8 6 7 5⁄8 7 3⁄8 9 1⁄4 9 1⁄4 (137) (194) (152) (194) (187) (235) (235) 12 1⁄4 15 1⁄4 15 1⁄4 15 1⁄4 24 5⁄16 27 1⁄2 27 1⁄2 (311) (387) (387) (387) (618) (699) (699) 10 14 11 14 14 20 20 (254) (355) (279) (355) (355) (508) (508) 14 10 14 11 14 14 20 (254) (355) (279) (355) (355) (508) 14 14 1 NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT) 0–1 3⁄4 w/o CPT 0–1 3⁄4 w/CPT 2–2 1⁄2 w/o CPT 2–2 1⁄2 w/CPT 3–3 1⁄2 w/o CPT 3–4 w/CPT 3 3 3 3 3 3 13 16 16 16 25 1⁄16 29 1⁄16 (330) (406) (406) (406) (637) (738) 12 5⁄8 17 1⁄8 13 1⁄4 17 1⁄8 17 3⁄16 23 3⁄16 (321) (435) (337) (435) (187) (589) 5 3⁄8 7 5⁄8 6 1⁄8 7 5⁄8 7 3⁄8 9 1⁄4 (137) (194) (156) (194) (187) (235) 12 1⁄4 15 1⁄4 15 1⁄4 15 1⁄4 24 5⁄16 27 9⁄16 (311) (387) (387) (387) (618) (700) ⁄ ⁄ 1⁄4 1⁄4 1⁄4 5⁄16 — — — — — — — — — — — — — — — — — — 34 41 41 41 55 61 (15) (19) (19) (19) (25) (28) ⁄ — — — — — — 28 (13) 14 D17150010 D17150010 D19673000 NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT) 0–2 1⁄2 3–4 4 4 23.780 (604) 39.37 (1000) 23.780 (604) 29.53 (750) 6.890 (175) 12.60 (320) — — — — 14 — 24139861003 24139861004 Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-123 NEMA & General Purpose Control 2 Speed 2 Winding Combination Two Speed Heavy Duty Starters Enclosed, Class 32 Dimensions Figure 2 Figure 1 7.0 3.0 3.0 8.5 3.5 3.5 H H Typical view top and bottom 1/2 X 3/4 Knockout 1 1/2 X 2 Knockout Typical view top and bottom 1/2 X 3/4 1 1/2 X 2 Knockout 1 1/2 X 2 Knockout Knockout 1 1/2 X 2 Knockout B E C D B D E C G GA A Mounting Holes for 1/4" Screws Qty. 4 E E D Mounting Holes for 1/4" Screws Qty. 4 D Figure 4 B Figure 3 C D CONTROL PRODUCTS 16 E AGH NEMA & General Purpose Control Mounting Holes for 1/4" Screws Qty. 4 NEMA 1 Standard Width 0–4 Mounting Dimensions A B C D E G H Approx Ship Wt Lbs (Kg) 24 (610) 36 (914) 24 (610) 36 (914) 20 (508) 24 (610) 20 (508) 24 (610) 8 (203) 8 (203) 8 (203) 8 (203) 15.00 (381) 14.00 (356) 15.00 (381) 14.00 (356) 2.125 (54) 5.00 (127) 2.125 (54) 5.00 (127) 21.00 (533) 33.50 (851) 21.00 (533) 33.50 (851) 3.50 (90) 3.50 (90) 3.50 (90) 3.50 (90) 68 (31) 71 (32) 135 (61) 138 (63) D68774 D68774 D68774 D68774 2.50 (64) 6.00 (152) 2.50 (64) 6.00 (152) 25.75 (654) 37.75 (959) 25.75 (654) 37.75 (959) 26.75 (680) 38.75 (984) 26.75 (680) 38.75 (984) 68 (31) 71 (32) 135 (61) 138 (63) D68774 D68774 D68774 D68774 Outline Dimensions Size 0–13⁄4 2–4 0–21⁄2, 3–4 Figure (1 Winding) (1 Winding) (2 Winding) (2 Winding) 1 2 1 2 Ref Dwg NEMA 12/3/3R/4 (Painted), 4/4X Stainless Standard Width 0–4 0–13⁄4 2–4 0–21⁄2, 3–4 (1 Winding) (1 Winding) (2 Winding) (2 Winding) 4 4 4 4 24 (610) 36 (914) 24 (610) 36 (914) 20 (508) 24 (610) 20 (508) 24 (610) 8 (203) 8 (203) 8 (203) 8 (203) 15.00 (381) 12 (305) 15.00 (381) 12 (305) Nema 4X Fiberglass 0–4 Size Figure Outline Dimensions A B C Mounting Dimensions D E 0–13⁄4 2–4 3 3 23.780 (604) 14.680 (373) 23.780 (604) 23.780 (604) 6.890 (175) 6.890 (175) 24.125 (613) 12.250 (311) 24.125 (613) 21.250 (540) Mtg Screw Conduit Size G K1 K2 1 ⁄4 ⁄4 1 — — Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed. 16-124 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog — — K3 Approx Ship Wt Lbs (Kg) Ref Dwg — — 18 (8) 28 (13) Reduced Voltage Starters Class 36, 37 Dimensions Figure 1 Figure 2 C H B K L Handle (Optional) C A D A Mounting Hole for 1/4" screw E B J (4) .687 Dia Holes Restricted Area for Auto Transformer D G E 16 CONTROL PRODUCTS Class 36, 37, NEMA 1, 4, 4X, 12/3R, Combination and Non-combination Reduced Voltage AutoTransformer Size 1 3/4 –2 1/2 3–3 1/2 4 5, 6 Part Winding & Wye Delta Circuit Disconnect Breaker 0–2 0–2 1/2 2 1/2 –3 1/2 3–3 1/2 4 4 5, 6 5, 6 Figure 1 1 1 2 A 43 5/16 55 5/16 74 21/32 90 B 24 5/32 28 9/32 28 9/32 29 30/31 C 11 11 11 20 D 42 11/32 54 11/32 73 13/32 16 E 20 24 24 24 7/16 G 2 1/16 2 1/8 2 1/8 2 16/21 H — — — 1 23/40 I — — — 2 J — — — 1 1/8 K — — — 8 3/40 L — — — 3 NEMA & General Purpose Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-125 Duplex Heavy Duty Controllers Class 83, 84 Dimensions Figure 1 Figure 2 Figure 3 A Class 83 Non-Combination Type Enclosure Type NEMA 1 CONTROL PRODUCTS 16 NEMA 12 NEMA 4/4X Size 0–13⁄4 2, 21⁄2 3–4 0–13⁄4 2, 21⁄2 3–4 0–13⁄4 2, 21⁄2 3–4 Outline Dimensions Figure A B 1 19 1⁄2 16 1⁄8 1 25 1⁄16 17 3⁄16 1 29 11⁄16 23 3⁄16 2 19 1⁄2 16 1⁄8 2 25 1⁄16 17 3⁄16 2 231⁄2 23 3⁄16 2 19 1⁄2 16 1⁄8 2 25 1⁄16 17 3⁄16 2 29 1⁄16 23 3⁄16 C 6 1⁄2 7 3⁄8 9 1⁄4 6 1⁄2 7 3⁄8 11 1⁄4 6 1⁄2 7 3⁄8 9 1⁄4 Mounting Dimensions D 18 3⁄4 24 5⁄16 27 9⁄16 18 3⁄4 24 5⁄16 27 9⁄16 18 3⁄4 24 5⁄16 27 9⁄16 C 79⁄16 911⁄16 79⁄16 Mounting Dimensions D 33 5413⁄16 33 E 13 14 20 13 14 20 13 14 20 Mounting Screw G 1⁄4 1⁄4 5⁄16 1⁄4 1⁄4 5⁄16 1⁄4 1⁄4 5⁄16 Conduit Size K1 K2 1⁄2–3⁄4 11⁄4–11⁄2 1⁄2–3⁄4 11⁄4–11⁄2 2–21⁄2 11⁄4–11⁄2 — — — — — — — — — — — — E 20 241⁄4 20 Mounting Screw G 3 ⁄8 3⁄8 3⁄8 Conduit Size K1 K2 7⁄8–11⁄8 7⁄8–11⁄8 — — — — K3 1⁄2 1⁄2–3⁄4 1⁄2–3⁄4 — — — — — — K4 1⁄2–3⁄4 11⁄4–11⁄2 11⁄4–11⁄2 — — — — — — K5 11⁄4–11⁄2 11⁄2–2 2–21⁄2–3 — — — — — — Approx Ship Wt Lbs 20 57 93 20 57 93 20 57 93 K5 123⁄64–123⁄32 — — Approx Ship Wt Lbs 70 106 — Class 84 Combination Type Enclosure Type NEMA 1 NEMA & General Purpose Control NEMA 4/4X/12 Size 0–21⁄2 3–4 0–4 Outline Dimensions Figure A B 3 341⁄8 245⁄8 3 56 281⁄2 3 341⁄8 245⁄8 Dimensions may vary for size 3 & 4 stainless steel enclosures. 16-126 NEMA 4 Painted, 4X Stainless Steel. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog K3 11⁄8–123⁄64 — — K4 11⁄8–123⁄64 — — Pump Control Panels Class 87, 88 Dimensions Outline Drawings Figure 1 Figure 2 F F Opening for Conduit Hub Size "P" Figure 3 C B E 5.000 C D A A G D B F Mounting Hole for 1/4" screw C F E B 6.000 Mounting Hole For 3/8" screw DG A Figure 4 C H B K L Handle (Optional) L L M Mounting Holes For 5/16" Hardware N 16 A CONTROL PRODUCTS H I J K J (4) .687 Dia Holes NEMA & General Purpose Control D F G E Class 87 Standard Pump Panel Size 21/2 1– 3–4 5 6 4 (Vac) Figure A 1 1 2 2 2 281/2 401/2 725/32 791/8 5531/32 B C 20 24 20 22 243/8 81/16 83/32 D 10 1215/16 922/32 E 24 36 71 78 5426/32 F — — 16 18 201/4 10 12 21/8 21/8 21/8 Conduit Knockout L M Hub P G H I J K 27 39 7029/32 777/8 5423/32 51/2 87/16 81/2 1115/16 111/2 157/16 141/2 — — — — — — — — — — 263/16 — 5 2714/32 — — — — D 42 11/32 54 11/32 73 13/32 16 E 20 24 24 24 716 — — — 1/ x 3/ 11/4 x 1 2 4 131/32 x 215/32 7/8 x 11/8 — — N 3/ 4 x1 — — 11/2 21/2 — Class 88 Reduced Voltage Pump Panels RVAT Size 2–2 1/2 3–3 1/2 4 5, 6 Part Winding & Wye Delta Fusible Circuit Disconnect Breaker 1–2 1–2 1/2 2 1/2–3 1/2 3–3 1/2 4 4 5, 6 5, 6 Figure 3 3 3 4 A 43 5/16 55 5/16 74 21/32 90 B 24 5/32 28 9/32 28 9/32 30 C 11 11 11 20 F 2 1/16 2 1/8 2 1/8 2 3/4 H — — — 1 1/2 I — — — — J — — — 1 1/8 K — — — 8 1/16 L — — — 3 Note: Dimensions in inches (millimeters). Dimensions for reference, not for construction. Contact Sales Office for dimensions not listed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-127 Lighting Contactors LE, CLM, CM Dimensions Figure 2 Figure 1 Figure 3 Figure 4 Figure 5 G K3 K2 K1 K2 K2 K2 K2 D A B K2 K2 E B G C GA C K1 K2 K2 K3 E K2 K3 D Enclosed Class LE, CLM, CM LE Lighting Non-Combination Rating NEMA & General Purpose Control CONTROL PRODUCTS 16 20A (2–12p), 30–60A (3p) — CLM Lighting Rating Outline Dimensions Fig D E 13 1 7 5 1 10 /32 6 /32 5 /32 8 /32 4 /8 1 1317/32 731/32 63/8 101/4 6 1 1 1 191/8 113/8 711/16 155/8 81/4 1 1 1 5 2 7 24 /8 26 48 3 13 /8 175/8 20 8 /8 121/2 121/2 21 /4 253/16 453/16 9 151/2 10 1 /4 1 /4 1 /4 1 /2– /4 1 /2–3/4 2–21/2 1 191/8 113/8 711/16 155/8 81/4 1 3 1 5 2 16 247/8 26 48 171/8 133/8 175/8 20 75/8 81/8 121/2 121/2 151/4 213/4 253/16 453/16 14 9 151/2 10 1 /4 /4 1 /4 1 /4 1 3 /4 /4 /4 /4 1 1 1 3 /2 K3 3 /2– /4 /2–3/4 /2–3/4 /4–1 K5 /4–1 — — 1–11/4 — — 11/2–2 — — 1 /4–1 /2 11/4–11/2 11/4–11/2 21/2 11/4–11/2 1 /2–3/4 — — 11/4–11/2 — — 2–21/2 1 1–11/4 11/2–2 — — 1 /2–3/4 /2–3/4 — 2–21/2 11/4–11/2 11/4 –11/2 11/4 –11/2 11/4 –11/2 11/4–11/2 2–21/2 11/4 –11/2 1 /2–3/4 — — — 11/4 –11/2 — — — 2–21/2 3 /2–3/4 1 1–1 1/4 K4 3 1 1 5 16 131/4 61/8 151/4 11 1 — — — — — 30–60A (6–12p) 3 16 171/8 75/8 151/4 14 1 — — — — — 5 26 131/8 79/16 251/4 10 1 5 /4 /4 — — — — — 200A 60–100A 300–400A 5 5 4 26 16 48 17 /8 13 20 12 /2 91/2 121/2 23 /16 151/8 49 15 /2 11 10 1 /4 1 /4 1 /4 — — — — — — — — — — — — — — — 20–30A 5 16 131/4 61/8 151/4 11 1 — — — — — — 5 26 131/8 79/16 251/4 10 1 — — — — — 11 151/2 10 1 — — — — — — — — — — — — — — — 60–100A 200A 300–400A Fusible and Non-fusible Disconnect Circuit Breaker 16-128 K2 20A (2–12p) 30–60A (3p) Type NEMA with & 12/3R & without 4/4X CPT K1 C 5 5 4 16 26 48 1 3 1 13 175/8 20 LE, CM Combination Conduit Size G B 30A (3p) 30–60A (6–12p), 100A 100A (3p) — 200A 200–400A — NEMA 1 — 300–400A 20A (2–12p), 30–60A (3–9p), 20–100A 100A (3p) with CPT — 30–60A (6–12p) 30–60A (12p) 200A 200–400A — — 300–400A 20A (2–12p) 20–30A 30–60A (3p) 31 Mtg Screw 1 without CPT — 30–60A (6–9p) without 100A (3p) CPT 200–400A — NEMA — 12/3R & 20A (2–12p) 4/4X 30–60A (3p) 30–60A (6–9p) with CPT 100A (3p) — 200–400A — A Mounting Dimensions 1 9 /2 121/2 121/2 /4 1 15 /8 253/16 49 /4 /4 /4 /4 1 /4 1 Outline Dimensions Lighting Ratings Fig A B C 20–60A 100A 200A 300A 20–100A 24 24 46 76 24 11 20 20 22 11 8 8 10 13 8 3 3 3 3 3 D Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog E G K1 K2 K3 Manual Control Class 11 - 3RV, SMF, MMS Wiring Diagrams Signaling Contact for Class 11 - 3RV Class 11 - 3RV Typical Wiring Diagrams—Class SMF 3RV1921-1M Typical Wiring Diagrams—MMS L3 L1 T1 L1 T2 L2 T2 L2 REVERSING SINGLE PHASE 3-LEAD REPULSION-INDUCTION MOTOR T3 L3 T3 L3 Reversing Manual Motor Starting Switch 2-Pole, 1-Phase L1 L3 T3 Pilot Lights (if used) L1 T1 T2 L2 T2 L2 T3 L3 T3 L3 Motor Reversing Manual Starter 3-Pole, 3-Phase L1 Pilot Lights (if used) 2-SPEED 2-WINDING SINGLE PHASE MOTOR Motor T1 2-Pole, 1-Phase with Pilot Lights 2-SPEED 2-WINDING WYE CONNECTED 3- PHASE MOTOR 3-Pole, 3-Phase 3-Pole Reversing Switches THREE PHASE MOTOR LINE AND MOTOR LEADS Line Meter L1 to L2 to L3 to T1 to T2 to T3 to L.H. UNIT _ _ _ T1 T2 T3 _ _ Pilot Light Leads to T1 T2 T3 R.H. UNIT L1 L2 L3 _ _ _ T1 T3 SINGLE PHASE CAPACITOR OR SPLIT PHASE MOTOR L.H. UNIT LINE AND MOTOR LEADS Line L1 to L2 to _ _ Meter T1 to T4 to T5 to T8 to T1 T3 L1 T2 Furnish Jumper L1 L2 _ _ _ _ L3 to _ _ Pilot Light Leads to T8 T4 Motor R.H. UNIT T2 T1 T3 T1 T5 SINGLE PHASE 4-LEAD REPULSION - INDUCTION MOTOR L.H. UNIT LINE AND MOTOR LEADS Line L1 to L2 to _ _ Meter T1 to T4 to T5 to T8 to T2 L3 T3 T1 Furnish Jumper L3 to _ _ Pilot Light Leads to T8 T1 R.H. UNIT L1 L2 _ _ _ _ T2 L1 T2 T5 T4 RUN START Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-129 NEMA & General Purpose Control T1 REV FWD COM L3 LOW HIGH T11 T3 T1 L1 T3 L1 L2 L3 L2 LOW T12 T13 T1 T2 T3 T1 L1 Pilot Light (if used) Motor L1 HIGH LOW L3 T3 REV (R.H. UNIT) COM T1 L1 FWD (L.H. UNIT) HIGH T1 L2 REV AC 2-Speed Manual Motor Starting Switches CONTROL PRODUCTS L1 FWD 16 AC Reversing Manual Starter and Manual Motor Starting Switches Heavy Duty Motor Starters Class 14 Wiring Diagrams 3-Phase and Single Phase Magnetic Starters Ambient Compensated Single Phase Sizes 00-2 1/2 Solid State Overload Single Phase Sizes 0-1 Ambient Compensated 3-Phase Sizes 00-2 1/2 Ambient Compensated 3-Phase Sizes 3-4 Solid State Overload 3-Phase Sizes 5-8 Solid State Overload 3-Phase Sizes 00-4 INCOMING LINE POWER WIRING: USE 75°C COPPER WIRE ONLY. SIZE CT RATIO 5 300:5 6 600:5 7 750:5 A B C CIRCUIT PROTECTIVE DEVICE (IF USED) X1 2CT NOTE A 16 "A" L1/1 3 8 L2 A1 1200:5 L3 "C " A2 REMOVE WIRE " C " IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. CONTROL PRODUCTS CONTACTOR M 2 "B " CURRENT TRANSFORMER (WHEN USED, SEE TABLE) RELAY 1CT 2CT X1 (IF USED) 3CT X1 X1 95 O.L. 96 T1 T2 T3 NEMA & General Purpose Control NOTES: A: 2CT IS LOCATED ON THE LINE SIDE OF CONTACTOR ON SIZE 7 STARTERS ONLY. Solid State Overload 3-Phase Wired as 1-Phase햲햳햴 햲 Warning: The ESP100 Starter and Single Phase Motor must be wired with polarity as shown. Neutral and L1 wires must be wired as indicated on the drawing. Polarity is indicated by the arrows. 16-130 햳 Full Load Amps (FLA): Adjustment of the ESP100 solid state overload relay (OL) must be made as follows to accommodate the single phase motor: For an approximate setting of a single phase motor application, multiply the motor nameplate FLA by .75 and set the Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog LOAD dial on the overload relay (OL) to resulting value. 3-phase for frame size A (without windows) can not be wired for single phase. Use the proper version for single phase. 햴 The Combination Heavy Duty Starters Class 17, 18 Wiring Diagrams 3-Phase THREE PHASE TO SUPPLY Size 0–4 L1 L2 L3 DISCONNECT or CIRCUIT BREAKER B 3 V M 1 T2 4 CONTROL FUSES (OPTIONAL) T3 OVERLOAD RELAY 95 96 XF C D M SEC FUSE H4 X1 H2 SEC T2 T1 ALTERNATE CONNECTIONS FOR TRANSFORMER W 2 T1 A H3 T3 X2 H1 16 Size 5–8 5 300:5 6 600:5 7 750:5 8 1200:5 wire “C” if control transformer is used. For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse line terminals. NEMA & General Purpose Control CT RATIO CONTROL PRODUCTS Remove SIZE Remove wire “C” if the contactor coil is to operate on a voltage other than line voltage or in a separate control source. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-131 Reversing Heavy Duty Starters Class 22 Wiring Diagrams 3-Phase Solid State Overload Solid State Overload Sizes 0- 1 3/4 Solid State Overload Sizes 2-4 Solid State Overload Sizes 5-6 TO SUPPLY L1 L2 L3 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR MECHANICAL INTERLOCK O.L. RELAY CURRENT TRANSFORMER (SEE TABLE) REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. MOTOR 3-Phase Ambient Compensated Overload Bimetal Overload Sizes 2-2 1/2 NEMA & General Purpose Control CONTROL PRODUCTS 16 Bimetal Overload Sizes 0-1 3/4 Single Phase Ambient Compensated Overload 3-Wire, 2-Pole Sizes 0-1 3/4 16-132 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Bimetal Overload Sizes 3-4 Combination Reversing Heavy Duty Starters Class 25, 26 Wiring Diagrams 3-Phase Size 0–4 TO SUPPLY L1 L2 L3 ALTERNATE CONNECTIONS FOR TRANSFORMER DISCONNECT or CIRCUIT BREAKER A B 10 9 3 7 V FOR W T1 T2 6 V REV W C 1 96 4 2 T3 8 5 OVERLOAD RELAY 95 96 CONTROL FUSES (OPTIONAL) XF SEC FUSE H4 X1 REMOVE WIRE "C" IF CONTROL TRANSFORMER IS USED. FOR SEPARATE CONTROL VOLTAGE SOURCE, REMOVE JUMPERS "A" AND "B" AND CONNECT SOURCE TO CONTROL FUSE LINE TERMINALS. H2 SEC T2 T1 M H3 T3 X2 H1 CONTROL TRANSFORMER (OPTIONAL) TO SUPPLY L1 L2 Size 5–6 L3 16 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR CONTROL PRODUCTS MECHANICAL INTERLOCK NEMA & General Purpose Control O.L. RELAY CURRENT TRANSFORMER (SEE TABLE) REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. MOTOR Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-133 Two Speed Heavy Duty Starters Class 30 & 32 Non- Combination and Combination Starters Wiring Diagrams 1 Winding Constant Horsepower Size 0–13/4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 DISCONNECT or CIRCUIT BREAKER DISCONNECT or CIRCUIT BREAKER HIGH B A T6 OL HIGH HIGH LOW HIGH LOW T4 T4 T5 LOW T1 OL LOW LOW A T2 LOW T3 T1 T3 6 5 95 2 T6 T2 CONSTANT HORSEPOWER MOTOR 3 6 LOW HIGH 5 4 7 V LOW W 3 8 V HIGH W T5 4 ALL OL'S 96 WIRING DIAGRAM TO SUPPLY L1 L2 L3 L3 7 HIGH LOW POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 T4 T5 T6 HIGH SPEED T6 T4 T5 HIGH C 1 96 2 OVERLOAD RELAY 95 96 OVERLOAD RELAY 95 96 T1 T6 8 T2 T3 T4 T5 LOW CONTROL FUSES (OPTIONAL) CONTROL TRANSFORMER (OPTIONAL) SEC FUSE XF H4 X1 H2 SEC T1 T2 T3 T4 T5 T6 D68785001 H3 M X2 H1 NEMA & General Purpose Control CONTROL PRODUCTS 16 1 Winding Constant Horsepower Size 2–4 D68785002 1 Winding Constant or Variable Torque Size 0–13/4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 DISCONNECT or CIRCUIT BREAKER LOW LOW HIGH T2 T3 HIGH T6 OL HIGH HIGH T4 HIGH T5 ALL OL'S 95 B A T1 HIGH 96 DISCONNECT or CIRCUIT BREAKER T4 OL LOW LOW A T3 T3 5 LOW 7 4 HIGH 6 5 7 V HIGH W 3 8 V LOW W T1 4 T2 T5 T6 VARIABLE TORQUE MOTOR 3 HIGH 6 2 T1 T2 T5 T6 CONSTANT TORQUE MOTOR T4 LOW POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 HIGH SPEED T6 T4 T5 T1 T2 T3 WIRING DIAGRAM TO SUPPLY L1 L2 L3 L3 LOW C 1 96 2 OVERLOAD RELAY 95 96 8 T6 T4 T5 T1 HIGH D68784001 CONTROL FUSES (OPTIONAL) OVERLOAD RELAY 95 96 T2 T3 XF CONTROL TRANSFORMER (OPTIONAL) SEC FUSE H4 X1 H2 T1 T2 T3 T4 T5 T6 SEC H3 M X2 H1 Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used. 16-134 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Two Speed Heavy Duty Starters Class 30 & 32 Non- Combination and Combination Starters Wiring Diagrams 1 Winding Constant or Variable Torque Size 2–4 ELEMENTARY DIAGRAM TO SUPPLY L1 L2 L3 DISCONNECT or CIRCUIT BREAKER LOW H H T3 HIGH T5 ALL OL'S 95 2 7 8 V H W 6 T1 T2 3 6 LOW 5 LOW 7 HIGH T3 OVERLOAD RELAY 95 96 T2 T5 T6 VARIABLE TORQUE MOTOR LOW 4 V LO W T1 T3 3 HIGH H 2 1 T4 T4 HIGH 96 T1 T3 T2 T5 T6 CONSTANT TORQUE MOTOR T6 OL HIGH HIGH A B T1 T2 H LOW WIRING DIAGRAM DISCONNECT or CIRCUIT BREAKER T4 OL LOW LOW A TO SUPPLY L1 L2 L3 8 H H V HI W 5 HIGH POSITION L1 L2 L3 TOGETHER LOW SPEED T1 T2 T3 HIGH SPEED T6 T4 T5 T1 T2 T3 T6 T4 4 T5 CONTROL FUSES (OPTIONAL) 1 96 OVERLOAD RELAY 95 96 C XF SEC FUSE H4 X1 H2 T1 T2 T3 T4 T5 T6 SEC H3 MOTOR X2 H1 CONTROL TRANSFORMER (OPTIONAL) D68784002 16 2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4 CONTROL PRODUCTS ELEMENTARY DIAGRAM TO SUPPLY L1 L2 L3 LOW T1 OL LOW T2 LOW T3 HIGH HIGH POSITION L1 L2 L3 LOW SPEED T1 T2 T3 HIGH SPEED T11 T12 T13 T3 V LOW W T12 T12 T13 ALL OL'S 95 T1 5 3 8 V HIGH W T11 OL HIGH HIGH 96 B A T2 LOW NEMA & General Purpose Control DISCONNECT or CIRCUIT BREAKER DISCONNECT or CIRCUIT BREAKER A WIRING DIAGRAM TO SUPPLY L1 L2 L3 5 LOW 6 4 HIGH 3 HIGH 7 2 LOW T1 T2 T3 OVERLOAD RELAY 95 96 T11 T13 TWO WINDING MOTOR HIGH 2 6 7 4 C 1 96 CONTROL FUSES (OPTIONAL) T11 T12 T13 OVERLOAD RELAY 95 96 CONTROL TRANSFORMER (OPTIONAL) 8 XF LOW T1 T2 T3 T11 T12 T13 SEC FUSE H4 X1 H2 SEC M H3 X2 H1 D68786001 Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-135 Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams NEMA & General Purpose Control CONTROL PRODUCTS 16 Part Winding EMT 16-136 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Auto Transformer TO SUPPLY L1 L2 L3 SEK SES SAW LMB SEK SES SAW LMB SEK SES SAW LMB OPTIONAL DISCONNECT OR CIRCUIT BREAKER OL 1S 3L1 0% 50% 1L1 R 65% 1CT 80% 2S L2 L3 100% L1 T1 2L1 OL 0% 50% 65% 80% R 1S 3L2 1L2 100% 2S 2CT * T2 2L2 FOR MOTOR HP SEE CONTROLLER NAMEPLATE MOTOR OL 4FU 71 MR 73 1S 0% 50% 65% 3L3 80% R FOR STARTER SIZES 1-4, 1CT-3CT ARE NOT USED. L1 1L3 100% 2S 3CT T3 2L3 1S 74 (A1) R 75 (A2) 2S 76 MR 5FU 72 L2 2S CR1 77 (A1) (A2) 1S * CR1 L1 H1 (A2) R H4 3FU L2 CPT X2 X1 CONNECT VOLTAGE AS SPECIFIED PER NAMEPLATE 2 3 2 LMB SAW SES SEK 1 X2 TR SUPPLIED AS REQUIRED 3 LMB SAW SES SEK NOTE E CONTROL PRODUCTS JUMPER 79 MECH INTLK (A1) 16 1FU 12 TAS 1 2FU 78 1S (A1) (A2) MR 4 (95) OL (96) 3 MR TR 6 (A1) (A2) CR1 NOTC Note E: Remove jumper if thermal protection switch is provided. HAND * 2 3 1PB OFF AUTO (A2) (A1) CR2 (A2) 3 2PB 5 1SS HAND AUTO CONTACT * 3 4 ETM OFF AUTO 1 RUN/ON/ RUNNING 3 4 3 5 1 (A1) 2PB START 2 1 1 * SURGE SUPPRESSOR START STOP 1 NEMA & General Purpose Control CONNECTIONS FOR OPTIONAL DEVICES 1SS * OFF 1LT AUTO CONTACT OL OL TRIPPED 9 X2 MR OFF/STOP X2 10 1 4LT ON 1 1SS * 3 1 5LT OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-137 Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Wye Delta (Open Transition) CUSTOMER'S INC. LINE Aÿ Bÿ Cÿ OPTIONAL DISCONNECT OR CIRCUIT BREAKER OL 1L1 1M T1 2M T6 1M T2 T1 1CT T6 OL 1L2 T1 T6 T2 S 2CT S S 2M T3 T4 T4 S T5 1M 1L3 T4 T5 OL T2 T3 T3 3CT 2M T5 FOR STARTER SIZES 1-4, 1CT-3CT ARE NOT USED. 1L1 1L2 4FU 50 MR 2M 51 CR1 52 53 (A1) 54 (A2) MR 55 S S S 56 57 * 5FU MECH (A1) (A2) INTERLOCK 2M 1M (A1) (A2) 1M SUPPLIED AS REQUIRED 3FU 2FU H1 1FU CONTROL PRODUCTS 16 1 H3 H2 H4 CPT 1X1 X1 X2 CONNECT VOLTAGE AS SPECIFIED PER NAMEPLATE X2 TR 1 3 2 2 MR (A1) TR 3 OL 4 (A2) MR (A1) 6 X2 (96) (95) (A2) CR1 NCTO NEMA & General Purpose Control CONNECTIONS FOR OPTIONAL DEVICES 2 3 1PB OFF HAND AUTO * (A2) (A1) START CR2 (A2) 3 2PB 5 1SS HAND AUTO CONTACT * 3 4 ETM OFF AUTO 1 RUN/ON/ RUNNING 3 4 3 5 1 (A1) 2PB 2 1 1 * SURGE SUPPRESSOR START STOP 1 1SS * OFF 1LT AUTO CONTACT OL OL TRIPPED 9 X2 MR OFF/STOP 10 X2 1 4LT ON 1 1SS * 3 1 5LT OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS 16-138 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Reduced Voltage Starters & Pump Panels Class 36, 37, 88 Wiring Diagrams Wye Delta (Closed Transition) CUSTOMER'S INC. LINE Aÿ Bÿ Cÿ OPTIONAL DISCONNECT OR CIRCUIT BREAKER OL 1M T1 T1 1CT 1L1 3L1 RES A 1A 2M T6 OL 1M 1L2 3L2 2CT RES B T1 T6 T2 T2 S 1A S S 2M T3 T4 S T5 1M 1L3 T4 T5 OL T3 3CT 3L3 RES C 2M T2 T3 1A FOR STARTER SIZES 1-4, 1CT-3CT ARE NOT USED. 1L2 1L1 4FU 50 MR 2M 51 CR1 52 53 (A1) (A2) MR 54 55 5FU 1A 1A S S 57 56 (A1) 58 (A1) (A2) S * MECH (A2) INTERLOCK 2M 1M (A1) (A2) 1M SUPPLIED AS REQUIRED 3FU 2FU 1FU 1 H3 H2 H4 CPT 1X1 X1 X2 6 X2 (A1) CONTROL PRODUCTS TR CONNECT VOLTAGE AS SPECIFIED PER NAMEPLATE 16 H1 (A2) CR1 NCTO TR 1 3 2 2 MR (A1) MR 4 (A2) OL (96) (95) X2 3 CONNECTIONS FOR OPTIONAL DEVICES 3 5 1SS HAND (A1) CR2 (A2) 3 AUTO CONTACT * 3 4 ETM OFF AUTO 1 RUN/ON/ RUNNING 3 4 3 5 1 START 2PB 1 * (A2) 2PB 2 1 (A1) NEMA & General Purpose Control 2 1PB OFF HAND AUTO * SURGE SUPPRESSOR START STOP 1 1SS * OFF 1LT AUTO CONTACT OL OL TRIPPED 9 X2 MR OFF/STOP X2 10 1 4LT ON 1 1SS * 3 1 5LT OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-139 Heavy Duty Contactors and Reversing Contactors Class 40, 43 Wiring Diagrams 3-Phase Magnetic Contactors and Reversing Contactors 3-Phase Contactors—Size 00–4 3-Phase Reversing Contactors—Size 00–4 3-Phase Contactors—Size 5, 6 3-Phase Reversing Contactors—Size 5, 6 TO SUPPLY L1 L2 L3 "REV" CONTACTOR "FWD" "FWD" CONTACTOR CONTRACTOR MECHANICAL 16 INTERLOCK CONTROL PRODUCTS NEMA & General Purpose Control RELAY CURRENT TRANSFORMER REMOVE WIRE "C" IF THE CONTACTOR COIL IS TO OPERATE ON A VOLTAGE OTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE. LOAD Single Phase Magnetic Contactors and Reversing Contactors Single Phase Contactors—Size 00–4 16-140 Single Phase Reversing Contactors—Size 00–1P Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Duplex Heavy Duty Controllers Class 83, 84 Standard Duplex Pump Panel (92) Wiring Duplex Panel w/o alternator (95) 16 CONTROL PRODUCTS NEMA & General Purpose Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-141 Duplex Heavy Duty Controllers Class 83, 84 Wiring Duplex Panel with Lead Pump Transfer Switch (94) NEMA & General Purpose Control CONTROL PRODUCTS 16 Duplex Panel with Relay Alternation (93) 16-142 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Standard Pump Panels & Current Sensitive Relays Class 87, 97 Wiring Standard Pump Panel Current Sensitive Relay 16 CONTROL PRODUCTS NEMA & General Purpose Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-143 Lighting and Heating Contactors Electrically Held, Class LE 20 AMP NEMA & General Purpose Control CONTROL PRODUCTS 16 30 – 100 AMP 200 – 400 AMP 16-144 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Wiring Diagrams Lighting and Heating Contactors Mechanically Latched 20 Amp, Class CLM ON Wiring Diagrams OFF L CONTACTOR CONTROL VOLTAGE OFF L ON C COMMON OR SEPARATE CONTROL LINES 5 ON 2 CR1 3 CR2 L CR2 CR1 0 CR1 CR2 C ON 0 OFF CONTROL MODULE VOLTAGE OFF 4 TYPICAL OFF-ON SELECTOR SWITCH COIL PILOT LIGHTS REQUIRE (1) EA. CLM4097291 AUXILIARY CONTACT KIT. 3 WIRE CONTROL ACC. 48 ON CONTACTOR CONTROL VOLTAGE OFF OFF HAND OFF AUTO 5 CR CR 5 CR2 0 3 CONTROL MODULE VOLTAGE 3 OFF L CR C L CR1 0 CR1 C 2 CONTROL MODULE VOLTAGE COIL 4 L CONTACTOR CONTROL VOLTAGE L CR1 CR2 COIL 4 REMOTE CONTROL ON ON ON-OFF (FORM 3) CONTROL ACC. 49 2 WIRE CONTROL ACC. 47 CONNECTIONS TO CONTROL MODULES CONTACTOR CONTROL VOLTAGE MODULE TERMINAL L OFF 1 5 L ON-OFF CONTROL MODULE VOLTAGE CR 0 CR C 3 CR NOT USED CONT. STATION FOR ACC. 48 & 49 3 CONT. STATION FOR ACC. 47,48 & 49 4 MODULE CONTROL VOLTAGE * 5 CONTACTOR CONTROL VOLTAGE O " CONTACTOR " TERMINAL O ON COIL 4 ON 2 WIRE CONTROL ACC. 47 2 CONNECT TO: C " CONTACTOR " TERMINAL C ON 16 * FOR 24 VDC CONTROL MODULES CONNECT TERMINAL 4 TO NEGATIVE (-) CONTROL PRODUCTS NEMA & General Purpose Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-145 Lighting and Heating Contactors Mechanically Latched 30–400 Amps, Class CLM Mechanically Latched, CLM 30–200 Connection Diagram for Common/Separate Control with Momentary Pushbutton or ON-OFF Selector Switch CLMOC, CLMOD, CLMOE, and CLMOF Connection for 2-Wire Control CLMOC, CLMOD, CLMOE, and CLMOF Connection for Hand/Off/Auto Control CLMOC, CLMOD, CLMOE, and CLMOF Mechanically Latched Type CLM 300 and 400 Amp NEMA & General Purpose Control CONTROL PRODUCTS 16 Wiring Diagrams Amps Connection Diagram for Common/Separate Control with Momentary Pushbutton or ON-OFF Selector Switch CLMOG and CLMOH Connection for 2-Wire Control CLMOG and CLMOH Control relay is required for 2-wire and Hand/Off/Auto Control, as shown in diagram. 16-146 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Connection for Hand/Off/Auto Control CLMOG and CLMOH Industrial Control Power Transformers Class MT, MTG Wiring Diagrams Voltage Letter A햲햴 Voltage Letter B햳 햴 Voltage Letter C햳 햴 When secondary fuse clips are installed, Terminal X1 becomes XF When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter D햳 Voltage Letter E햲 햴 When secondary fuse clips are installed, Terminal X1 becomes XF When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter G햲 Voltage Letter H Voltage Letter I When secondary fuse clips are installed, Terminal X1 becomes XF Does not include secondary fuse clips Does not include secondary fuse clips Voltage Letter J 햳햴 Voltage Letter L Voltage Letter M햲 When secondary fuse clips are installed, Terminal X3 becomes XF Does not include secondary fuse clips When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter F햲 When secondary fuse clips are installed, Terminal X1 becomes XF 16 CONTROL PRODUCTS NEMA & General Purpose Control When secondary fuse clips are installed, Terminal X1 becomes XF Voltage Letter P H1 햲 햳 햴 Includes secondary fuse clips on sizes 50-750VA Includes secondary fuse clips on sizes 50-500VA Secondary fuse clips are not included on MTG transformers. X2 380V 24V H2 X1 Does not include secondary fuse clips Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-147 Overload Relay Heater Tables Selection of Heater Elements for Overload Relays Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average values, for motors with service factor of 1.15, are to be used only as a guide. The formulas at the bottom of the page may be used to obtain approximate amps for other motors. Note: RPM shown for 60 cycle motors. For 50 cycle motors, multiply RPM by .83. 3-Phase 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 CONTROL PRODUCTS 16 1 11⁄2 2 NEMA & General Purpose Control 3 5 71⁄2 10 15 20 50 Hz Syn Speed RPM 200 Volts 230 Volts 460 Volts 575 Volts 1800 1200 900 1800 1200 900 1800 1200 900 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 1.09 1.61 1.84 1.37 1.83 2.07 1.98 2.47 2.74 2.83 3.36 3.75 3.22 4.09 4.32 4.95 5.01 5.59 6.07 6.44 6.44 7.36 7.87 9.09 9.59 10.8 11.7 13.1 15.5 16.6 18.2 18.3 22.4 24.7 25.1 26.5 29.2 30.8 32.2 35.1 41.9 45.1 47.6 51.2 58.0 58.9 60.7 63.1 0.95 1.40 1.60 1.19 1.59 1.80 1.72 2.15 2.38 2.46 2.82 3.26 2.80 3.56 3.76 4.30 4.36 4.86 5.28 5.60 5.60 6.40 6.84 7.90 8.34 9.40 10.2 11.4 13.5 14.4 15.8 15.9 19.5 21.5 21.8 23.0 25.4 25.8 28.0 30.5 36.4 39.2 41.4 44.5 50.4 51.2 52.8 54.9 0.48 0.70 0.80 0.60 0.80 0.90 0.86 1.08 1.19 1.23 1.46 1.63 1.40 1.78 1.88 2.15 2.18 2.43 2.64 2.80 2.80 3.20 3.42 3.95 4.17 4.70 5.12 5.70 5.76 7.21 7.91 7.92 9.79 10.7 10.9 11.5 12.7 13.4 14.0 15.2 18.2 19.6 20.7 22.2 25.2 25.6 26.4 27.4 0.38 0.56 0.64 0.48 0.64 0.72 0.69 0.86 0.95 0.98 1.17 1.30 1.12 1.42 1.50 1.72 1.74 1.94 2.11 2.24 2.24 2.56 2.74 3.16 3.34 3.76 4.10 4.55 5.41 5.78 6.32 6.33 7.81 8.55 8.70 9.19 10.1 10.7 11.2 12.2 14.5 15.7 16.5 17.8 20.1 20.5 21.1 21.9 Formula—Approximate Full Load Amps for Other Motors 208 Volt Full Load Amp 앒 230 Volt current ҂ 110% 2-Phase FLA 앒 0.866 ҂ the 3-Phase FLA 2-Phase, 3-wire current in common wire 앒 1.41 ҂ that in the other 2 lines 16-148 1-Phase Full Load Current (60Hz) Hp 1 ⁄8 1 ⁄4 1 ⁄3 1 ⁄2 3 ⁄4 1 1 1⁄2 2 3 5 7 1⁄2 10 115 Volts 230 Volts 4.4 5.8 7.2 9.8 13.8 16 20 24 34 56 80 100 2.2 2.9 3.6 4.9 6.9 8 10 12 17 28 40 50 3-Phase Full Load Current (60Hz) Hp General CAUTION: Actual motor amps may be higher or lower than the values listed below for a particular motor. For more reliable motor protection, select heater elements by using the full load motor nameplate amps. Single Phase motor full load amps of the same horsepower, voltage and speed vary over wide ranges. The following table conforms with table 430.148 of the NEC. 380 Volts 0.55 0.81 0.93 0.64 0.92 1.04 0.99 1.24 1.38 1.42 — 1.88 1.70 2.06 2.28 2.60 2.69 2.94 3.20 3.39 3.39 3.84 4.14 4.77 5.02 5.70 6.20 6.80 8.20 8.74 9.59 9.60 11.50 13.00 13.20 13.90 15.40 16.30 16.90 18.50 22.00 23.70 25.00 26.90 30.50 31.00 31.90 33.20 Full Load Current (60Hz) Hp 25 30 40 50 60 75 100 125 150 200 250 300 400 50 Hz Syn Speed RPM 200 Volts 230 Volts 460 Volts 575 Volts 380 Volts 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 3600 1800 1200 900 1800 1200 1800 69.9 74.5 75.4 77.4 84.8 86.9 90.6 94.1 111 116 117 121 138 143 145 150 164 171 173 177 206 210 212 222 266 271 275 290 — — — — — — — — — — — — — — — — — — — 60.8 64.8 65.6 67.3 73.7 75.6 78.8 81.8 96.4 101 102 105 120 124 126 130 143 149 150 154 179 183 184 193 231 236 239 252 292 293 298 305 343 348 350 365 458 452 460 482 559 568 573 600 278 684 896 30.4 32.4 32.8 33.7 36.8 37.8 39.4 40.9 48.2 50.4 50.6 52.2 60.1 62.2 63.0 65.0 71.7 74.5 75.0 77.0 89.6 91.6 92.0 96.5 115 118 120 126 146 147 149 153 171 174 174 183 229 226 230 241 279 284 287 300 339 342 448 24.3 25.9 26.2 27.0 29.4 30.2 31.5 32.7 38.5 40.3 40.4 41.7 48.2 49.7 50.4 52.0 57.3 59.4 60.0 61.5 71.7 73.2 73.5 77.5 92.2 94.8 95.6 101 116 117 119 122 137 139 139 146 184 181 184 193 223 227 229 240 271 274 358 36.80 39.20 39.60 40.70 — 45.70 47.60 49.50 — 61.00 61.20 63.20 — 75.20 76.20 78.50 — 90.00 91.10 93.10 — 111.00 112.00 117.00 — 144.00 145.00 153.00 — 177.00 180.00 186.00 — 210.00 210.00 211.00 — 274.00 276.00 279.00 — 343.00 345.00 347.00 392.00 395.00 — 25Hz 1500 RPM, amps 앒 amps of 60Hz, 3600 RPM 25Hz 750 RPM, amps 앒 amps of 60Hz, 1800 RPM Service factor 1.0 앒 amps ҂ 0.9 50°C–55°C motor 앒 amps ҂ 0.9 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Overload Relay Heater Tables Selection of Heater Elements for Overload Relays General To Select Heater Catalog Number Use 2. Refer to the specified table and use ▪ ▪ ▪ ▪ the controller size and motor amps to select the heater catalog number. a. If motor amps are not known, an approximate value may be found on the previous page. These values should be used with caution and only when motor amps are not available. Heaters shown on the following pages provide a maximum trip rating of 125% of minimum motor amperes for 40˚C motors (service factor 1.15). For other motors (service factor 1.0), select the next lower listed heater catalog number within the designated table which provides a maximum trip rating of approximately 115%. Product Class Controller Size Motor Amp Phase Catalog No 14 C P 3 2 B C 81 Phase Size Class 1. Find heater table number below, using the Product Class, Controller Size and Phase. Heater table number is found in the column under the type of overload and phase. Overload relays do not provide protection against short circuits. To ensure proper coordination with short circuit protective device, select heaters from the information packaged with the control device. Heater Table Number Size or Amperage Controller Size Letter Bimetal Standard Trip (Class 20) Bimetal Quick Trip (Class 10) Compensated E Heaters Green Reset Compensated K Heaters Green Reset Class Description SMF Manual All — 14, 22 Magnetic Non-reversing, Reversing 00-4 B–J 213 233 313 332 0-4 C-J — 233 — 332 25-180A D–J 216 238 316 335 1Ph 3Ph CONTROL PRODUCTS 48 Combination Reversing Combination Multi Speed Pump Controllers Motor Control Centers Panel Mounted Overload Relay 3Ph See Page 16-150 16 17, 18 25, 26 30, 32 83, 84 87, 89 1Ph NEMA & General Purpose Control ESP100 starters do not require heater elements. Overload Relay Selection Multi-Speed Each speed requires a separate set of overloads. The adjustment range must be selected on the basis of the full-load current for each particular speed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-149 Manual Control Heater Elements, Class SMF General Ordering Information 1. Determine number of heater elements required from Table A. 2. Determine motor full load current and service factor. NOTE: If motor amps are unknown, an approximate value may be found on page 16-148. These values should be used with caution and only when motor amps are not available. 3. If the motor and controller are in the same ambient temperature: a. For 1.15 to 1.25 service factor motors use 100% of motor full load current for heater element selection. b. For 1.0 service factor motors use 90% of motor full load current for heater element selection. 4. If the motor and controller are in different ambient temperatures multiply motor full load current by the multiplier in Table B. Use the resultant full load current for heater element selection. Heater Elements Class SMF 5. Select proper heater element from table below. 6. All tables are based on the operation of the motor and controller in the same ambient temperature, 40°C (104°F) or NEMA & General Purpose Control CONTROL PRODUCTS 16 less. Always be certain the correct heater element is installed in the starter before operating the motor. Heater Catalog Number Motor Full-Load Current (Amps) List Price $ Heater Catalog Number Motor Full-Load Current (Amps) List Price $ SMFH01 SMFH02 SMFH03 SMFH04 SMFH05 SMFH06 SMFH07 SMFH08 SMFH09 SMFH10 SMFH11 SMFH12 SMFH13 SMFH14 SMFH15 SMFH16 SMFH17 SMFH18 SMFH19 SMFH20 SMFH21 SMFH22 SMFH23 SMFH24 SMFH25 SMFH26 0.157–0.173 0.174–0.192 0.193–0.212 0.213–0.235 0.236–0.261 0.262–0.289 0.290–0.321 0.322–0.355 0.356–0.399 0.41–0.44 0.45–0.49 0.50–0.53 0.54–0.58 0.59–0.65 0.66–0.71 0.72–0.78 0.79–0.85 0.86–0.96 0.97–1.04 1.05–1.16 1.17–1.25 1.30–1.39 1.38–1.54 1.48–1.63 1.57–1.75 1.66–1.86 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 SMFH27 SMFH28 SMFH29 SMFH30 SMFH31 SMFH32 SMFH33 SMFH34 SMFH35 SMFH36 SMFH37 SMFH38 SMFH39 SMFH40 SMFH41 SMFH42 SMFH43 SMFH44 SMFH45 SMFH46 SMFH47 SMFH48 SMFH49 SMFH50 SMFH51 SMFH52 1.80–1.99 1.96–2.15 2.16–2.38 2.39–2.75 2.76–2.84 2.85–3.06 3.07–3.45 3.46–3.70 3.71–4.07 4.08–4.32 4.33–4.90 4.91–5.35 5.36–5.85 5.86–6.41 6.42–6.79 6.80–7.57 7.58–8.15 8.16–8.98 8.99–9.67 9.68–9.95 9.96–10.8 10.9–12.1 12.2–13.1 13.2–13.9 14.0–15.0 15.1–16.0 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Table A Number of Heater Elements Device SMFF*1 SMFF*2 SMFF*3 SMFF*4 SMFF*5 SMFF*6 SMFF*22 SMFF*44 SMFF*11 SMFF*22 16-150 Number of Heater Elements 1 2 2 Table B—Special Applications Heater Element Selection Notes Ambient Temperature of Motor All single pole and two pole SMF starters require only 1 Heater Element. Same as Controller Ambient Duplex Unit. One Heater Element per starter. Two Speed Starter. One Heater Element per speed. Continuous Duty Motor Service Factor 1.15 to 1.25 1.0 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Constant 10°C (18°F) Higher Than Controller Ambient Constant 10°C (18°F) Lower Than Controller Ambient Full Load Current Multiplier 1.0 0.9 0.9 0.8 1.05 0.95 Discount Schedule NEMA Overload Relay Heater Tables Full Load Motor Amps, Single Phase, Trip Class 20 – Tables 213, 216 Table 213 for Class 14, 22 (1-Phase) Full Load Amps 0.37–0.40 0.41–0.44 0.45–0.47 0.48–0.52 0.53–0.57 0.58–0.62 0.63–0.69 0.70–0.74 0.75–0.81 0.82–0.85 0.86–0.93 0.94–1.03 1.04–1.11 1.12–1.22 1.23–1.34 1.35–1.53 1.54–1.71 1.72–1.92 1.93–2.12 2.13–2.24 2.25–2.43 2.44–2.57 2.58–2.86 2.87–3.16 3.17–3.35 3.36–3.58 3.59–3.90 3.91–4.25 4.26–4.77 4.78–5.35 5.36–5.76 5.77–6.33 6.34–6.98 6.99–7.37 7.38–7.71 7.72–8.51 8.52–9.31 9.32–10.1 10.2–10.9 11.0–12.2 12.3–13.5 13.6–15.7 15.8–17.3 17.4–19.9 20.0–21.7 21.8–23.4 23.5–24.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 19.4–22.0 22.1–23.5 23.6–25.0 25.1–27.0 27.1–28.9 29.0–31.0 31.1–34.8 34.9–36.9 37.0–43.9 44.0–46.0 46.1–48.3 48.4–55.0 55.1–60.0 E3 E4 E5 E6 E7 E8 E9 E11 E12 E13 E14 E16 E17 E18 E23 E24 E26 E27 E28 E29 E31 E32 E33 E34 E36 E37 E38 E39 E41 E42 E44 E46 E47 E48 E49 E50 E51 E52 E53 E54 E55 E56 E57 E60 E61 E62 E65 E66 E67 E69 E70 E72 E73 E74 E76 — 0.41–0.44 0.45–0.47 0.48–0.52 0.53–0.57 0.58–0.62 0.63–0.69 0.70–0.74 0.75–0.81 0.82–0.85 0.86–0.93 0.94–1.03 1.04–1.11 1.12–1.22 1.23–1.34 1.35–1.53 1.54–1.71 1.72–1.92 1.93–2.12 2.13–2.24 2.25–2.43 2.44–2.57 2.58–2.86 2.87–3.16 3.17–3.35 3.36–3.58 3.59–3.90 3.91–4.25 4.26–4.77 4.78–5.35 5.36–5.76 5.77–6.33 6.34–6.98 6.99–7.37 7.38–7.71 7.72–8.51 8.52–9.31 9.32–10.1 10.2–10.9 11.0–12.2 12.3–13.5 13.6–15.7 15.8–17.3 17.4–19.9 20.0–21.7 21.8–23.4 23.5–23.7 23.8–25.1 25.2–27.9 28.0–32.2 32.3–34.0 — — — — Discount Schedule NEMA Full Load Amps List Price $ 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 48DA, 48GA 48HA 48JA Heater Catalog No 0.34–0.36 0.37–0.40 0.41–0.43 0.44–0.47 0.48–0.51 0.52–0.56 0.57–0.62 0.63–0.67 0.68–0.73 0.74–0.77 0.78–0.84 0.85–0.93 0.94–1.00 1.01–1.10 — 1.11–1.21 1.22–1.38 1.39–1.54 1.55–1.73 1.74–1.91 1.92–2.02 2.03–2.19 2.20–2.32 2.33–2.58 2.59–2.85 2.86–3.02 3.03–3.23 3.24–3.52 3.53–3.83 3.84–4.30 4.31–4.82 4.83–5.19 5.20–5.71 5.72–6.29 6.30–6.64 6.65–6.95 6.96–7.67 7.68–8.39 8.40–9.19 9.20–9.94 9.95–10.9 11.0–12.2 12.3–14.2 14.3–15.6 — 15.7–17.9 18.0–19.6 19.7–22.3 22.4–24.0 24.1–25.9 26.0–29.5 29.6–32.5 32.6–33.5 33.6–36.9 37.0–39.2 39.3–43.1 43.2–47.4 47.5–50.0 50.1–55.2 55.3–60.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 50.0–55.9 56.0–60.9 61.0–65.9 66.0–69.9 70.0–75.9 76.0–81.9 82.0–86.9 87.0–92.9 93.0–97.9 98.0–107.9 108.0–113.9 114.0–125.0 126.0–138.0 139.0–153.0 154.0–163.0 164.0–180.0 E3 E4 E5 E6 E7 E8 E9 E11 E12 E13 E14 E16 E17 E18 E19 E23 E24 E26 E27 E28 E29 E31 E32 E33 E34 E36 E37 E38 E39 E41 E42 E44 E46 E47 E48 E49 E50 E51 E52 E53 E54 E55 E56 E57 E59 E60 E61 E62 E65 E66 E67 E69 E70 E71 E72 E73 E74 E76 E77 E78 E79 E80 E88 E89 E91 E92 E93 E94 E96 E97 E98 E99 E101 E102 E103 E104 E106 E107 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 27.1–30.0 30.1–33.2 33.3–35.7 35.8–39.4 39.5–43.4 43.5–46.9 47.0–51.5 51.6–57.0 57.1–62.8 62.9–69.1 69.2–75.0 75.1–83.3 — — — — — — 83.4–86.9 87.0–92.9 93.0–100.0 — — — — — — — List Price $ 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEMA & General Purpose Control Heater Catalog No CONTROL PRODUCTS Size 2, 21⁄2 Table 216 for Class 48 16 Size 00, 0, 1 Size 1P Selection 16-151 Overload Relay Heater Tables Full Load Motor Amps, 3-Phase, Trip Class 20 – Tables 233, 238 Table 233 for Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87 (3-Phase) NEMA & General Purpose Control CONTROL PRODUCTS 16 Full Load Amps Size 00, 0, 1 Size 13⁄4 Size 2, 21⁄2 Size 3, 31⁄2 Size 4 Heater Catalog No 0.38–0.40 0.41–0.43 0.44–0.48 0.49–0.53 0.54–0.57 0.58–0.62 0.63–0.66 0.67–0.72 0.73–0.80 0.81–0.85 0.86–0.92 0.93–0.99 1.00–1.08 1.09–1.23 1.24–1.37 1.38–1.54 1.55–1.69 1.70–1.80 1.81–1.94 1.95–2.07 2.08–2.26 2.27–2.54 2.55–2.69 2.70–2.88 2.89–3.14 3.15–3.40 3.41–3.81 3.82–4.26 4.27–4.62 4.63–5.09 5.10–5.61 5.62–5.91 5.92–6.15 6.16–6.70 6.71–7.54 7.55–8.29 8.30–8.99 9.00–9.85 9.86–10.4 10.5–12.0 12.1–13.6 13.7–15.6 15.7–17.0 17.1–18.4 18.5–19.4 19.5–21.3 21.4–24.4 24.5–25.9 26.0–27.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 10.5–12.0 12.1–13.6 13.7–15.6 15.7–17.1 17.2–19.4 19.5–20.9 21.0–22.2 22.3–25.3 25.4–26.9 27.0–30.2 — 30.3–33.3 33.4–35.3 — 35.4–41.5 41.6–45.0 45.1–52.3 52.4–55.7 55.8–60.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 30.0–33.5 33.6–36.4 36.5–39.6 — 39.7–43.6 43.7–46.5 46.6–51.6 51.7–54.4 54.5–58.0 58.1–63.0 63.1–67.7 67.8–72.4 — — — — — 72.5–80.0 80.1–88.1 88.2–91.5 91.6–96.8 96.9–99.0 99.1–108.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 56.9–60.9 61.0–63.9 64.0–67.7 67.8–72.4 72.5–77.7 77.8–85.9 86.0–91.9 92.0–96.7 96.8–105 — — 106–115 116–130 E6 E7 E8 E9 E11 E12 E13 E14 E16 E17 E18 E19 E23 E24 E26 E27 E28 E29 E31 E32 E33 E34 E36 E37 E38 E39 E41 E42 E44 E46 E47 E48 E49 E50 E51 E52 E53 E54 E55 E56 E57 E60 E61 E62 E65 E66 E67 E69 E70 E71 E72 E73 E73A E74 E76 E77 E78 E79 E80 E88 E89 E91 E92 E93 E94 E96 E97 E98 E99 E101 E102 E103 E104 16-152 — — — — — — — — — — — — — — — — — — — — — 2.27–2.54 2.55–2.69 2.70–2.88 2.89–3.14 3.15–3.40 3.41–3.81 3.82–4.25 4.26–4.62 4.63–5.09 5.10–5.61 5.62–5.91 5.92–6.15 6.16–6.70 6.71–7.54 7.55–8.29 8.30–8.99 9.00–9.85 9.86–10.4 10.5–12.0 12.1–13.6 13.7–15.6 15.7–17.0 17.1–19.4 19.5–20.9 21.0–22.2 22.3–25.3 25.4–26.9 27.0–30.2 — 30.3–33.3 33.4–36.0 — — — — — — — — — — — — — — — — — — — — — Selection Table 238 for Class 48 Full Load Amps List Price $ 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 48DC 48GC 48HA 48JA Heater Catalog No 0.30–0.32 0.33–0.35 0.36–0.38 0.39–0.41 0.42–0.44 0.45–0.49 0.50–0.54 0.55–0.58 0.59–0.63 0.64–0.67 0.68–0.73 0.74–0.81 0.82–0.87 0.88–0.94 0.95–1.00 1.01–1.10 1.11–1.26 1.27–1.40 1.41–1.58 1.59–1.74 1.75–1.85 1.86–1.99 2.00–2.11 2.12–2.31 2.32–2.59 2.60–2.75 2.76–2.95 2.96–3.21 3.22–3.48 3.49–3.89 3.90–4.35 4.36–4.73 4.74–5.21 5.22–5.74 5.75–6.05 6.06–6.46 6.47–6.95 6.96–8.09 8.10–9.29 9.30–10.4 — 10.5–10.9 11.0–12.0 12.1–14.5 14.6–16.8 16.9–18.4 18.5–20.9 21.0–22.5 22.6–24.3 24.4–27.2 27.3–29.2 29.3–30.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 16.9–18.4 18.5–20.9 21.0–22.5 22.6–24.7 24.8–27.2 27.3–29.2 29.3–32.0 32.1–34.9 — 35.0–37.8 37.9–41.7 41.8–45.9 46.0–49.0 49.1–54.2 54.3–60.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 27.1–30.0 30.1–33.2 33.3–35.7 35.8–39.4 39.5–43.4 43.5–46.9 — 47.0–51.5 51.6–57.0 57.1–62.8 62.9–69.1 69.2–75.0 75.1–83.3 — — — — — — 83.4–86.9 87.0–92.9 93.0–100.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 50.0–55.9 56.0–60.9 61.0–65.9 66.0–69.9 70.0–75.9 76.0–81.9 82.0–86.9 87.0–92.9 93.0–97.9 98.0–107.9 108–113.9 114–125.9 126–138.9 139–153.9 154–163.9 164–180.9 E3 E4 E5 E6 E7 E8 E9 E11 E12 E13 E14 E16 E17 E18 E19 E23 E24 E26 E27 E28 E29 E31 E32 E33 E34 E36 E37 E38 E39 E41 E42 E44 E46 E47 E48 E49 E50 E51 E52 E53 E54 E55 E56 E57 E60 E61 E62 E65 E66 E67 E69 E70 E71 E72 E73 E73A E74 E76 E77 E78 E79 E80 E88 E89 E91 E92 E93 E94 E96 E97 E98 E99 E101 E102 E103 E104 E106 E107 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog List Price $ 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Discount Schedule NEMA Overload Relay Heater Tables Full Load Motor Amps, Single Phase, Trip Class 10 – Tables 313, 316 Table 313 for Class 14, 22 (1-Phase) Full Load Amps Size 2, 21⁄2 Heater Catalog No 1.85–2.05 2.06–2.35 2.36–2.64 2.65–2.96 2.97–3.31 3.32–3.51 3.52–3.87 3.88–4.31 4.32–4.79 4.80–5.21 5.22–5.75 5.76–6.11 6.12–6.95 6.96–7.73 7.74–8.47 8.48–9.52 9.53–10.4 10.5–11.1 11.2–12.4 12.5–13.5 13.6–15.1 15.2–16.6 16.7–17.6 17.7–18.8 18.9–21.6 21.7–22.7 22.8–25.3 — — — — — — — — — — — 1.85–2.05 2.06–2.35 2.36–2.64 2.65–2.96 2.97–3.31 3.32–3.51 3.52–3.87 3.88–4.31 4.32–4.79 4.80–5.21 5.22–5.75 5.76–6.11 6.12–6.95 6.96–7.73 7.74–8.47 8.48–9.52 9.53–10.4 10.5–11.1 11.2–12.4 12.5–13.5 13.6–15.1 15.2–16.6 16.7–17.6 17.7–18.8 18.9–21.6 21.7–22.7 22.8–25.3 25.4–26.6 26.7–30.1 30.2–33.0 33.1–34.1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 18.7–19.7 19.8–21.3 21.4–22.8 22.9–24.2 24.3–26.5 26.6–29.3 29.4–32.0 32.1–35.6 35.7–37.9 38.0–40.3 40.4–44.3 44.4–49.5 49.6–52.1 52.2–53.7 53.8–60.0 K21 K22 K24 K27 K28 K29 K31 K32 K33 K34 K36 K37 K39 K41 K42 K43 K49 K50 K52 K53 K54 K55 K57 K58 K60 K61 K62 K63 K64 K67 K68 K69 K70 K72 K73 K74 K75 K76 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 48DA 48GA 48HA 48JA Heater Catalog No 1.69–1.88 1.89–2.05 2.06–2.21 2.22–2.44 2.45–2.70 2.71–2.92 2.93–3.27 3.28–3.56 3.57–3.83 3.84–4.23 4.24–4.57 4.58–4.97 4.98–5.67 5.68–6.11 6.12–6.91 6.92–7.65 7.66–8.4 8.5–8.9 9.0–10.1 10.2–11.2 11.3–12.3 12.4–13.3 13.4–14.1 14.2–15.0 15.1–16.2 16.3–17.5 17.6–18.6 18.7–19.9 20.0–21.3 21.4–22.8 22.9–25.1 25.2–27.6 27.7–30.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 9.12–9.6 9.7–10.4 10.5–11.4 11.5–12.1 12.2–12.9 13.0–13.7 13.8–14.8 14.9–16.4 16.5–18.2 18.3–19.5 19.6–20.9 21.0–22.8 22.9–24.7 24.8–27.6 27.7–30.5 30.6–33.9 34.0–37.3 37.4–40.2 40.3–41.9 42.0–45.9 46.0–50.9 51.0–52.9 53.0–57.7 57.8–60.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 23.2–25.1 25.2–27.3 27.4–30.4 30.5–33.3 33.4–36.5 36.6–39.3 39.4–43.5 43.6–46.6 46.7–51.1 51.2–56.3 56.4–61.1 61.2–64.9 65.0–71.9 72.0–80.7 80.8–92.7 92.8–100.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 43.0–46.5 46.6–50.9 51.0–55.9 56.0–59.1 59.2–68.7 — 68.8–80.7 80.8–92.7 92.8–103.9 104.0–113.5 113.6–127.9 128.0–143.9 144.0–163.9 164.0–180.0 K21 K22 K23 K24 K26 K27 K28 K29 K31 K32 K33 K34 K36 K37 K39 K41 K42 K43 K49 K50 K52 K53 K54 K55 K56 K57 K58 K60 K61 K62 K63 K64 K67 K68 K69 K70 K72 K73 K74 K75 K76 K77 K78 K85 K86 K87 K89 K92 K94 K96 List Price $ 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEMA & General Purpose Control Discount Schedule NEMA Full Load Amps List Price $ CONTROL PRODUCTS Size 1P 16 Size 00, 0, 1 Selection Table 316 for Class 48 16-153 Overload Relay Heater Tables Full Load Motor Amps, 3-Phase, Trip Class 10 – Tables 332, 335 Table 332 for Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87 (3-Phase) Full Load Amps NEMA & General Purpose Control CONTROL PRODUCTS 16 Size 00, 0, 1 1.52–1.65 1.66–1.79 1.80–1.94 1.95–2.15 2.16–2.37 2.38–2.56 2.57–2.87 2.88–3.13 3.14–3.37 3.38–3.72 3.73–4.00 4.01–4.35 4.36–4.99 5.00–5.38 5.39–5.79 5.80–6.43 6.44–6.83 6.84–7.83 7.84–8.23 8.24–9.59 9.60–9.90 10.0–10.7 10.8–11.6 11.7–12.3 12.4–13.4 13.5–14.2 14.3–15.1 15.2–17.5 17.6–18.7 18.8–20.0 20.1–21.5 21.6–23.9 24.0–25.8 — — — — — — — — — — — — — — — — — — — — 16-154 3 Size 1 ⁄4 1.52–1.65 1.66–1.79 1.80–1.94 1.95–2.15 2.16–2.37 2.38–2.56 2.57–2.87 2.88–3.13 3.14–3.37 3.38–3.72 3.73–4.00 4.01–4.35 4.36–4.99 5.00–5.38 5.39–5.79 5.80–6.43 6.44–6.83 6.84–7.83 7.84–8.23 8.24–9.59 9.60–9.90 10.0–10.7 10.8–11.6 11.7–12.3 12.4–13.4 13.5–14.2 14.3–15.1 15.2–17.5 17.6–18.7 18.8–20.0 20.1–21.5 21.6–23.9 24.0–25.8 25.9–29.5 — 29.6–32.7 32.8–36.0 — — — — — — — — — — — — — — — — Size 2, 2 ⁄2 1 — — — — — — — — — — — — — — — — — — — — — — 12.1–12.7 12.8–13.5 13.6–14.6 14.7–15.9 16.0–16.9 17.0–18.2 18.3–19.5 19.6–20.9 21.0–23.1 23.2–25.4 25.5–27.9 — 28.0–30.5 30.6–33.5 33.6–37.2 37.3–40.7 40.8–43.0 43.1–47.9 48.0–52.7 52.8–58.3 58.4–60.0 — — — — — — — — — — Size 3, 3 ⁄2 1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 36.8–40.0 40.1–42.4 42.5–46.3 46.4–49.6 49.7–52.3 52.4–57.5 57.6–63.9 64.0–67.9 68.0–74.3 74.4–77.9 78.0–83.1 83.2–91.4 91.5–99.9 100.0–108.0 — — — — Size 4 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 49.7–52.3 52.4–57.5 57.6–63.0 63.1–68.1 68.2–74.3 74.4–79.9 80.0–87.4 87.5–90.0 90.1–100.0 100.1–108.0 108.1–119.0 119.1–130.0 — — Heater Catalog No List Price $ K21 K22 K23 K24 K26 K27 K28 K29 K31 K32 K33 K34 K36 K37 K39 K41 K42 K43 K49 K50 K52 K53 K54 K55 K56 K57 K58 K60 K61 K62 K63 K64 K67 K68 K69 K70 K72 K73 K74 K75 K76 K77 K78 K83 K85 K86 K87 K88 K89 K90 K92 K94 K96 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Selection Table 335 for Class 48 Full Load Amps 48DC 48GC 48HA 48JA 1.56–1.69 1.70–1.84 1.85–1.98 1.99–2.19 2.20–2.43 2.44–2.63 2.64–2.95 2.96–3.21 3.22–3.45 3.46–3.81 3.82–4.10 4.11–4.46 4.47–5.10 5.11–5.49 5.50–6.21 6.22–6.76 6.77–7.62 7.63–8.07 8.08–9.19 9.20–10.0 10.1–11.0 11.1–12.0 12.1–12.7 12.8–13.5 13.6–14.5 14.6–15.7 15.8–16.7 16.8–17.9 18.0–19.2 19.3–20.5 20.6–22.5 22.6–24.8 24.9–27.6 27.7–30.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 18.0–19.2 19.3–20.5 20.6–22.5 22.6–24.8 24.9–27.6 — 27.7–30.1 30.2–33.1 33.2–36.7 36.8–40.1 40.2–45.5 45.6–47.9 48.0–52.7 52.8–55.1 55.2–60.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 23.2–25.1 25.2–27.3 27.4–30.4 30.5–33.3 33.4–36.5 36.6–39.3 39.4–43.5 43.6–46.6 46.7–51.1 51.2–56.3 56.4–61.1 61.2–64.9 65.0–71.9 72.0–80.7 80.8–92.7 92.8–100.0 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 43.0–46.5 46.6–50.9 51.0–55.9 56.0–59.1 59.2–68.7 — 68.8–80.7 80.8–92.7 92.8–103.9 104.0–113.5 113.6–127.9 128.0–143.9 144.0–163.9 164.0–180.0 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Heater Catalog No K21 K22 K23 K24 K26 K27 K28 K29 K31 K32 K33 K34 K36 K37 K39 K41 K42 K43 K49 K50 K52 K53 K54 K55 K56 K57 K58 K60 K61 K62 K63 K64 K67 K68 K69 K70 K72 K73 K74 K75 K76 K77 K78 K85 K86 K87 K89 K92 K94 K96 List Price $ 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Discount Schedule NEMA Replacement Parts Starters and Contactors – AC Coils Selection Ordering Information 䊳 4th character of starter or contactor catalog number indicates model. AC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88 Volts Size Catalog Number 24 110 110/190–220 — 190–220 240 190–220/380–440 380–440 550 24 110 110/190–220 — 190–220 240 190–220/380–440 380–440 550 24 110 110/190–220 — 190–220 240 190–220/380–440 380–440 550 23-26 110-127 200-220 220-240 240-277 380-420 440-480 575-600 23-26 110-127 200-220 220-240 240-277 380-420 440-480 575-600 23-26 110-127 200-220 220-240 240-277 380-420 440-480 575-600 75D73070J 75D73070F 75D73070A 75D73070D 75D73070G 75D73070L 75D73070C 75D73070H 75D73070E 75D73251J 75D73251F 75D73251A 75D73251D 75D73251G 75D73251L 75D73251C 75D73251H 75D73251E 75D70131J 75D70131F 75D70131A 75D70131D 75D70131G 75D70131L 75D70131C 75D70131H 75D70131E 3RT1966-5AB31 3RT1966-5AF31 3RT1966-5AM31 3RT1966-5AP31 3RT1966-5AU31 3RT1966-5AV31 3RT1966-5AR31 3RT1966-5AT31 3RT1965-5AB31 3RT1965-5AF31 3RT1965-5AM31 3RT1965-5AP31 3RT1965-5AU31 3RT1965-5AV31 3RT1965-5AR31 3RT1965-5AT31 3RT1975-5AB31 3RT1975-5AF31 3RT1975-5AM31 3RT1975-5AP31 3RT1975-5AU31 3RT1975-5AV31 3RT1975-5AR31 3RT1975-5AT31 List Price $ 67.00 67.00 67.00 67.00 67.00 67.00 67.00 67.00 67.00 144.00 144.00 144.00 144.00 144.00 144.00 144.00 144.00 144.00 173.00 173.00 173.00 173.00 173.00 173.00 173.00 173.00 173.00 176.00 176.00 176.00 176.00 176.00 176.00 176.00 176.00 165.00 165.00 165.00 165.00 165.00 165.00 165.00 165.00 213.00 213.00 213.00 213.00 213.00 213.00 213.00 213.00 00–21⁄2 P S (ESP100) 3 , 31⁄2 P S (ESP100) 4 G T (ESP100) 4, 5 V (Vacuum) 5 P 6 P V (Vacuum) 7 H 100-250 150-500 100-250 150-500 75ZAF750-70 75ZAF750-71 587.00 587.00 8 H 100-250 100-250 75ZAF1650-70 1029.00 Set of 2 coils. Recommend to change printed circuit board when changing coils. 49ZP1650 for List Price see page 16-156. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-155 NEMA & General Purpose Control 50Hz 24 120 110–120/220–240 208 220–240 277 220–240/440–480 440–480 575–600 24 120 110–120/220–240 208 220–240 277 220–240/440–480 440–480 575–600 24 120 120/220–240 208 220–240 277 220–240/440–480 440–480 575–600 23-26 110-127 200-220 220-240 240-277 380-420 440-480 575-600 23-26 110-127 200-220 220-240 240-277 380-420 440-480 575-600 23-26 110-127 200-220 220-240 240-277 380-420 440-480 575-600 CONTROL PRODUCTS Code: SIRIUS 3R, Contactors, OL's, MSP's. 60Hz 16 Discount Model Replacement Parts Starters and Contactors – DC Coils, Late Break Aux Contacts, Rectifiers, Contact Kits Selection Ordering Information 䊳 䊳 4th character of starter or contactor catalog number indicates model. DC Coils for Size 00-4 require Late Break Interlock. DC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43 Size Model 00–21⁄2 P S (ESP 100) 3, 31⁄2 P S (ESP 100) 4 G T (ESP 100) 4, 5 V (Vacuum) Volts DC Catalog Number 12 24 32 48 125 250 12 24 32 48 125 250 48 125 250 23-26 42-48 110-127 240-277 75D73070R 75D73070S 75D73070T 75D73070U 75D73070V 75D73070W 75D73251R 75D73251S 75D73251T 75D73251U 75D73251V 75D73251W 75D70131U 75D70131V 75D70131W 3RT1966-5AB31 3RT1966-5AD31 3RT1966-5AF31 3RT1966-5AU31 List Price $ 99.00 99.00 99.00 99.00 99.00 99.00 213.00 213.00 213.00 213.00 213.00 213.00 338.00 338.00 338.00 176.00 176.00 176.00 176.00 Note: For sizes 7 & 8 contactors the AC coils are used for DC see page 16-155. Board for Size 8 Contactor CONTROL PRODUCTS 16 Late Break Auxiliary Contacts Control Size Model Catalog Number List Price $ 00–4 P, G, S, T 49AB01LB 51.00 Model Catalog Number List Price 8 H 49ZP1650 Contact Kits – Single Pole Stationary and Movable Contacts, Contact Spring Description Size Number of Poles in Kit 3 NEMA & General Purpose Control Control Size Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88 14, 40 Discount Discount 16-156 Internal Aux Contact (00-1- ⁄4) 00 0 1 13⁄4–1P 2 21⁄2 3 31⁄2 4 4 (Vacuum) 5 5 (Vacuum) 6 6 (Vacuum) 7 8 Code: IEC. Code: NEMA Control. 1 1 1 1 1 3 (Bottles) 3 3 (Bottles) 3 3 (Bottles) 3 3 Model (4th position in part number) P, S P, S P, S P, S P, S P, S P, S P, S P, S G, T V, C P V, C P V, C H H On 3-phase controls, all 3-poles should be replaced 3 kits required. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Catalog Number 75AF14 75BF14 75CF14 75DF14 75EF14 75FP14 75GP14 75HF14 75IF14 75JG14 3RT1964-6V 3RT1966-6A 3RT1966-6V 3RT1976-6A 3RT1976-6V 49ZL750 49ZL1650 List Price $ 20.00 22.00 34.00 45.00 67.00 81.00 120.00 144.00 223.00 290.00 1161.00 1054.00 1704.00 1395.00 2130.00 4428.00 5468.00 1811.00 Replacement Parts Starters and Contactors – Coil VA Ratings and Overload Relays Selection Coil VA Ratings Device Type NEMA Starter Lighting Contactor Mechanically Held (CLM) Volts — — — — — — — — — — — — — — — 24 120 208 240 277 480 600 24 120 208 240 277 480 600 24 120 208 240 277 480 600 24 120 208 240 277 480 600 24 120 208 240 277 480 600 All Voltages Electrically Held Number of Poles Total Inrush VA Total Sealed VA — — — — — — — — 2-12 2-5 2-3 4-5 2-3 4-5 3 3 3 3 3 3 3 3 12 12 12 12 12 12 12 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 218 310 510 590 830 850 1900 630 6 40 40 40 200 130 550 49.6 51.3 75.79 86.78 79.1 83.7 84.1 73.31 75.1 73.97 89.15 78.55 84 81.9 49.67 51.94 76.57 64.44 77.85 83.6 82.1 74.94 75.77 78.73 89.92 84.89 87.6 85.4 182.28 191.42 187.78 215.32 175.92 198.2 171.1 300 590 830 25 26 51 6.7 9.2 12 48 7.4 625 410 410 600 900 1300 1600 6.9 6.57 11.94 14.25 11.97 12.9 13.2 12.66 13.1 13.25 14.85 12.77 12.9 13.4 7.08 6.48 11.78 8.99 14.2 13.1 13.4 13.16 13.59 12.05 14.42 12.93 12.7 13.8 32.85 32.26 31.15 35.63 30.62 34.8 29.6 5.8 6.7 9.2 NEMA & General Purpose Control — — — — — — — — 20 30 60 60 100 - 200 100 - 200 300 - 400 20 20 20 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 60 60 60 60 60 60 60 100 100 100 100 100 100 100 200 300 400 CONTROL PRODUCTS Amps 00 thru 2 1/2 3 thru 3 1/2 4 5 6 7 8 4,5,6 (Vacuum) — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 16 Lighting Contactor Electrically Held Held (LE) Contactor Size Overload Relays – For Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87 Size Half Size Ambient Comp Bimetal Model 00–1 — P 1P — — 13⁄4 P P 2 — P — 21⁄2 P 3 — 4 — 31⁄2 — P P G Number Poles Catalog Number (1) NC List Price $ 1 3 1 3 1 3 1 3 3 3 3 48DC18AA3 48DC38AA3 48EC18AA3 48EC38AA3 48GC18AA3 48GC38AA3 48GC18AA3 48GC38AA3 48HC38AA3 48HC38AA3 48JC38AA3 116.00 120.00 151.00 155.00 165.00 169.00 165.00 169.00 286.00 286.00 430.00 Catalog Number (1) NO/NC List Price $ 48DC39AA3 155.00 48EC39AA3 191.00 48GC39AA3 205.00 48GC39AA3 205.00 For Starter and Contactor replacement parts not found in this section, please refer to Field Modification kits found starting on page 16-79. For replacement Solid State overload relays, please see the Overload Relay section found starting on page 16-47. Includes overload mounting plate to be coupled to contactor mounting plate. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-157 Replacement Parts Lighting and Heating Contactors, Type LE, CLM, CMF, CMN Selection AC Coils – 20-400 Amps Type LE 3 RT 1 9 5 5 - 5 A F 3 1 Contactor Size Catalog Number 24VAC 120VAC 208VAC 240VAC 277VAC 480VAC 600VAC List Price $ 20, 30, 60 Amp 75D70646J 75D70646F 75D70646D 75D70646G 75D70646L 75D70646H 75D70646E 100 Amp 75D54772J 75D54772F 75D54772D 75D54772G 75D54772L 75D54772H 75D54772E 56.00 200 Amp 3RT1955-5AB31 3RT1955-5AF31 3RT1955-5AM31 3RT1955-5AP31 3RT1955-5AU31 3RT1955-5AR31 3RT1955-5AT31 133.00 300 Amp 3RT1965-5AB31 3RT1965-5AF31 3RT1965-5AM31 3RT1965-5AP31 3RT1965-5AU31 3RT1965-5AR31 3RT1965-5AT31 165.00 400 Amp 3RT1975-5AB31 3RT1975-5AF31 3RT1975-5AM31 3RT1975-5AP31 3RT1975-5AU31 3RT1975-5AR31 3RT1975-5AT31 213.00 93.00 Main Contacts (Includes 3 Moving and 6 Fixed Contacts) Type LE 3 RT 1 9 6 5 - 6 A Contactor Size Catalog Number 20–100 Amp Not Replaceable List Price $ 200 Amp 3RT1956-6A 300 Amp 3RT1965-6A 847.00 400 Amp 3RT1975-6A 1193.00 — 554.00 Lighting Contact Assembly - 20 Amp (Power Poles) Type Catalog Number Contactor Size (Verify catalog number on side of contact assembly) 49LN02A, 2 NC Contacts Non-Stackable LE 20 Amp List Price $ 101.00 49LN20A, 2 NO Contacts Non-Stackable 101.00 49LS20A, 2 NO Contacts Stackable 101.00 49LS10A, 1 NO Contact Stackable 101.00 CONTROL PRODUCTS 16 AC Coils 20 Amps CLM4097341 Type Contactor Size Number of Poles 120V, 60Hz 110V, 50Hz List Price $ 240V, 60Hz 208V, 50Hz List Price $ 277V 50/60Hz CLM 20 Amp 2–12 CLM4097341 103.00 CLM4097342 103.00 CLM4097343 List Price $ 480V, 60Hz 440V, 50Hz List Price $ 103.00 CLM4097344 103.00 AC Coils 30–400 Amps NEMA & General Purpose Control CLMC4C120 CLMGU3C120 Type Contactor Size CLM†C 30 Amp CLM†D 60 Amp CLM†E 100, 200 Amp CLM†G Latching Coil Unlatch Coil CLM†H Latching Coil Unlatch Coil Catalog Number Number of Poles 24V AC 120V AC 208V AC 220/240V AC 277V AC 480V AC 600V AC List Price $ 2–3-Pole 4-Pole 5-Pole 2–3-Pole 4-Pole 5-Pole 2–3-Pole 4-Pole 5-Pole CLMC4C024 CLMC4C024 CLMC5C024 CLMD3C024 CLMD5C024 CLMD5C024 CLME3C024 CLME5C024 CLME5C024 CLMC4C120 CLMC4C120 CLMC5C120 CLMD3C120 CLMD5C120 CLMD5C120 CLME3C120 CLME5C120 CLME5C120 CLMC4C208 CLMC4C208 CLMC5C208 CLMD3C208 CLMD5C208 CLMD5C208 CLME3C208 CLME5C208 CLME5C208 CLMC4C240 CLMC4C240 CLMC5C240 CLMD3C240 CLMD5C240 CLMD5C240 CLME3C240 CLME5C240 CLME5C240 CLMC4C277 CLMC4C277 CLMC5C277 CLMD3C277 CLMD5C277 CLMD5C277 CLME3C277 CLME5C277 CLME5C277 CLMC4C480 CLMC4C480 CLMC5C480 CLMD3C480 CLMD5C480 CLMD5C480 CLME3C480 CLME5C480 CLME5C480 CLMC4C600 CLMC4C600 CLMC5C600 CLMD3C600 CLMD5C600 CLMD5C600 CLME3C600 CLME5C600 CLME5C600 119.00 119.00 119.00 141.00 141.00 141.00 237.00 237.00 237.00 300 Amp 2–3-Pole 2–3-Pole — — CLMGL3C120 CLMGL3C208 CLMGL3C240 CLMGL3C277 CLMGL3C480 CLMGL3C600 511.00 CLMGU3C120 CLMGU3C208 CLMGU3C240 CLMGU3C277 CLMGU3C480 CLMGU3C600 511.00. 400 Amp 2–3-Pole 2–3-Pole — — CLMHL3C120 CLMHL3C208 CLMHL3C240 CLMHL3C277 CLMHL3C480 CLMHL3C600 583.00 CLMHU3C120 CLMHU3C208 CLMHU3C240 CLMHU3C277 CLMHU3C480 CLMHU3C600 583.00 Control Module Rectifier Type Device Contactor Size Number of Poles Catalog Number List Price $ CLM CLM†C to CLM†F 30–200 Amps All CLMKCMR 167.00 Discount code: IEC. Coil kits for 20 amp CLM contactors include the coil clearing auxiliary contact. 16-158 For 30–200 amp CLM contactors, in the event that either the coil or the control module fails, it is recommended that both be replaced. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Replacement Parts Lighting Contactors, CLM, CMB, CMF, CMN & Combination Replacement Handles Selection Ordering Information 䊳 䊳 For CLM: 5th character of contactor catalog number indicates Frame Size. For CMB, CMF, CMN: 4th character of contactor catalog number indicates Frame Size. Main Contacts 20 Amp Lighting Contactors Type CLM Contactor Size Number of Poles Location Catalog Number List Price $ 20 Amp 2 3 4 6 Top or Bottom Top Top or Bottom Top or Bottom CLM4097331 CLM4097332 CLM4097333 CLM4097334 258.00 290.00 355.00 419.00 CLM4097334 Main Contacts 30–400 Amp Lighting Contactors Type CLM Number of Poles Catalog Number List Price $ C 30 Amp 2 3 4 5 CLMCCK02 CLMCCK03 CLMCCK04 CLMCCK05 133.00 192.00 223.00 268.00 D 60 Amp 2 3 4 5 CLMDCK02 CLMDCK03 CLMDCK04 CLMDCK05 155.00 252.00 533.00 564.00 E 100 Amp 2 3 4 5 CLMECK02 CLMECK03 CLMECK04 CLMECK05 300.00 449.00 600.00 752.00 F 200 Amp 2 3 4 5 CLMFCK02 CLMFCK03 CLMFCK04 CLMFCK05 578.00 863.00 1151.00 1438.00 G 300 Amp 2 3 CLMGCK02 CLMGCK03 1428.00 2118.00 H 400 Amp 2 3 CLMHCK02 CLMHCK03 2766.00 4152.00 CONTROL PRODUCTS Contactor Size 16 Frame Size Auxiliary Contact Blocks 20 Amp Lighting Contactors Type Contactor Size CLM 20 Amp Contacts Catalog Number List Price $ 1 Form C NO, NC Contact 2 Form C NO, NC Contacts CLM4097291 CLM4097292 97.00 193.00 Auxiliary Contact Blocks 30–400 Amp Lighting Contactors Frame Size Contactor Size C to F 30–200 Amps G to H 300–400 Amps CLM CLMFCAK11 Contact Configuration Catalog Number List Price $ 1 NO and 1 NC 2 NC 2 NO 1 Coil Clearing NO and NC CLMFCAK11 CLMFCAK02 CLMFCAK20 CLMFCCK11 71.00 71.00 71.00 71.00 1 NO and 1 NC 2 NC 2 NO 1 Coil Clearing NO and NC CLMHCAK11 CLMHCAK02 CLMHCAK20 CLMHCCK11 71.00 71.00 71.00 71.00 NEMA & General Purpose Control Type Combination Starters Class 17, 18, 25, 26 & 32 Replacement Handle Assemblies NEMA 1, 4, 12 Enclosure Class 17, 25, 32 Disc Standard List Extra Size Width Price $ Wide 30-100A 200A Maximum Maximum 75D68257103 75D68257105 269.00 269.00 75D68257103 — List Price $ 269.00 — NEMA 1, 4, 12 Enclosure Class 18, 26, 32 Circuit Standard List Extra Breaker Width Price $ Wide 3-100A 125A 150A 75D68257080 75D68257096 75D68257089 269.00 269.00 269.00 75D68257080 — — List Price $ 269.00 — — 1 block per contactor. 2 blocks per contactor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-159 Definite Purpose Control Definite Purpose Contactors General Class 45 45CG10AJA 45CG20AF Benefits ▪ Power Termination Options ▪ Compact Size ▪ One Pole Version Includes Shunt Bar ▪ Interchangeable Mounting Durable Metal Back Plate ▪ Standard Class B Coil Insulation 45EG10AJA ▪ ▪ ▪ ▪ ▪ 45EG20AF Quiet Operation Weld-resistant Silver Cadmium Oxide Contacts Power Terminal Operations Reinforced Thermalset Polyester Housing Contact Covers and Taped Coils Come Standard CONTROL PRODUCTS 16 Class 42 Definite Purpose Control 42AF35AF 42DF35AF Benefits ▪ Compact Size ▪ Interchangeable Mounting Durable Metal Back Plate ▪ Power Terminations Options ▪ Reinforced Thermalset Polyester Housing ▪ Quiet Operation Common Definite Purpose Applications ▪ Air Conditioning ▪ Heating ▪ Ventilating ▪ Refrigeration ▪ Food and Beverage Industry ▪ Conveyors 42FE35AF106 ▪ ▪ ▪ ▪ ▪ Weld-resistant Silver Cadmium Oxide Contacts Optional Din Rail Mounting Snap-on Electrical/Mechanical Interlocks Visual Contact Position Indication Low VA Coils Standard for 25A–40A ▪ ▪ ▪ ▪ ▪ Elevators Lighting Pool and Spa Welding Pump and Compressor For further products and dimensions see supplement catalog DPBR-18010-0905. New supplement catalog to be ready Summer 2007. 16-160 42HF35AF Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Definite Purpose Control Definite Purpose Contactors Selection Coil Table Ordering Information 䊳 䊳 Use complete catalog number. Replace the (*) with letter from the coil table. For additional information see Definite Purpose Catalog DPBR-18010-0905. 60Hz 24 110–120 200–208 208–240 277 440–480 550–600 50Hz Voltage 24 110 — 190–220 240 380–440 550 Letter J F D G L H E Class 45 FLA 120V Hp 240V LRA 20 25 30 35 40 — — — — — 120 150 180 200 240 20 25 30 35 40 — — — — — — — — — — Hp 277V LRA — — — — — 110 150 180 180 240 — — — — — 120 150 180 200 240 Hp 480V LRA — — — — — 100 100 150 150 200 — — — — — 100 125 135 135 200 Hp 600V LRA — — — — — 80 80 120 120 160 — — — — — 80 100 110 110 160 Hp Non Inductive Amps Poles Catalog No List Price $ — — — — — 25 35 40 50 55 1 1 1 1 1 45CG10A*A 45DG10A*A 45EG10A*A 45FG10A*A 45GG10A*A 44.50 40. 48.50 55.00 49. 61.00 54. 66.00 — — — — — 30 35 40 50 55 2 2 2 2 2 45CG20A* 45DG20A* 45EG20A* 45FG20A* 45GG20A* 66.00 87.00 96.00 102.00 107.00 59. 78. 85. 91. 96. Class 42 25–150 FLA 60Hz 600V AC Max Hp 277V LRA Hp 480V LRA Hp 600V LRA Hp Non Inductive Amps Poles Catalog No 3 5 5 — — — — — — 125 125 125 — 7.5 7.5 100 100 100 — 7.5 7.5 35 35 35 2 3 4 42AF15A* 42AF35A* 42AF25A* 101.00 117.00 104. 158.00 141. 180 180 180 5 7.5 7.5 — — — — — — 150 150 150 — 10 10 120 120 120 — 10 10 40 40 40 2 3 4 42BF15A* 42BF35A* 42BF25A* 122.00 109. 130.00 116. 172.00 1154. 3 — — 240 240 240 7.5 10 10 — — — — — — 200 200 200 — 15 15 160 160 160 — 15 15 50 50 50 2 3 4 42CF15A* 42CF35A* 42CF25A* 137.00 122. 152.00 136. 196.00 176. 50 50 3 — 300 300 10 15 — — — — 250 250 — 30 200 200 — 30 63 63 2 3 42DF15A* 42DF35A* 282.00 253. 299.00 268. 60 60 5 — 360 360 10 20 — — — — 300 300 — 40 240 240 — 40 75 75 2 3 42EF15A* 42EF35A* 320.00 286. 333.00 298. 75 75 — — 450 450 25 25 — — — — 375 375 — 40 300 300 — 40 93 93 2 3 42FE15A*106 42FE35A*106 383.00 343. 428.00 383. 90 90 — — 540 540 — 30 — — — — 450 450 — 60 360 360 — 60 120 120 2 3 42GE15A*106 42GE35A*106 496.00 443. 536.00 479. 120 120 — — 720 720 — — — — — — 600 600 — — 480 480 — — 150 150 2 3 42HF15A* 42HF35A* 607.00 543. 660.00 591. 150 150 — — 900 900 — — — — — — 750 750 — — 600 600 — — 160 160 2 3 42IF15A* 42IF35A* 1172.00 1048. 1293.00 1156. 25 25 25 2 — — 150 150 150 30 30 30 2 — — 40 40 40 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-161 Definite Purpose Control Discount Schedule NEMA List Price $ CONTROL PRODUCTS 240V LRA 16 FLA 120V Hp SIRIUS Soft Starters Introduction Overview Products at a glance 3RW30/3RW31 3RW40 3RW44 Class 73/74 Enclosed Order No. Page 3RW30, 3RW31 16-164 3RW40 16-165 3RW44 16-166 Class 73/74 16-168/16-169 SIRIUS soft starters for standard applications SIRIUS 3RW30 soft starters • SIRIUS 3RW30/31 soft starters for soft starting and smooth ramp-down of single-phase or three-phase asynchronous motors1) • Rating range of up to 60 Hp at 460 V (50 °C ambient) • Application areas: - Fans - Pumps - Building/construction machines - Presses - Escalators - Transport systems SIRIUS 3RW40 soft starters - Air conditioning systems Ventilators Assembly lines Compressors and coolers Operating mechanisms • SIRIUS 3RW40 soft starters with integrated functions - solid-state motor overload and intrinsic device protection and - adjustable current limiting for the soft starting and stopping of three-phase asynchronous motors • Rating range from 75 to 300 Hp at 460 V (50 °C ambient) CONTROL PRODUCTS 16 • Application areas: - Fans - Pumps - Building/construction machines - Presses - Escalators - Transport systems - Air conditioning systems Ventilators Assembly lines Compressors and coolers Operating mechanisms for High Feature applications SIRIUS 3RW44 soft starters • In addition to soft starting and soft ramp-down, the solid-state SIRIUS 3RW44 soft starters provide numerous functions for higher-level requirements • Rating range from - up to 600 Hp at 460 V in inline circuit • Application areas: - Pumps - Ventilators - Compressors - Cooling systems - Industrial refrigerating systems - Water transport Conveying systems Hydraulics Machine tools Mills For enclosed applications Enclosures in NEMA 1, 3, 4, & 12 types • Complete starter includes 3RW40 or 3RW44 and CPT UL/CSA listed • Combination options include circuit breaker or fusible DBC Soft Starter Control • Application areas: - Compressors - Pumps - Stamping presses - Cooling towers - Molding and extruding - Chippers and debarkers - Lumber processing Pulp & paper processing Conveyors Textiles HVAC 1) 3RW30 single phase devices do not have ramp down functionality. 16-162 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog SIRIUS Soft Starters General Data Overview The advantages of the SIRIUS soft starters at a glance: • Soft starting and soft stop1) • Stepless starting • Reduction of current peaks • Avoidance of mains voltage fluctuations during starting • Reduced load on the power supply network Rated current at 50 °C Rated operating voltage Motor rating at 460 V • Inline circuit • Inside-delta circuit Temperature range SIRIUS 3RW40 SIRIUS 3RW44 High Feature applications A V 2.6 ... 85 200 ... 575 117 ... 385 200 ... 600 26 ... 1076 200 ... 690 Hp Hp °C 1.1 ... 60 – -25 ... +60 75 ... 300 – -25 ... +60 15 ... 950 22 ... 600 0 ... +60 40 ... 100 0 ... 20 – – – – 20 ... 100 1 ... 360 1) % s % % s 40 ... 100 0 ... 20 – – – – 20 ... 100 20 ... 200 1 ... 360 2) – – – – – – – – – – – – – – – – 1 – 2 controlled phases 6) 3) 6) 3) 6) with PROFIBUS DP (option) (option ) 4) 3 3 controlled phases 5) – – 6) Win-SOFTSTARTER Technical Assistance 1-800-241-4453 Function is available – Function not available 5) For 3RW30 03 up to 230 V. 6) Calculate soft starter and motor with size allowance where required. 1) 2) 3) 4) You can find further information on the Internet at: http://sielect.sea.siemens.com Soft stop not available for 3RW31. Not available for 3RW30 03. Not possible in inside-delta circuit. Trace function with Softstarter ES software. Soft Starter Control – – – – – – – – – – – – – – – – – – – 1 (2 with 3RW31) – 2 controlled phases (only 3RW30 03) CONTROL PRODUCTS Integral bypass contact system Intrinsic device protection Motor overload protection Thermistor motor protection Adjustable current limiting Inside-delta circuit Breakaway pulse Creep speed in both directions Pump ramp-down DC braking Combined braking Motor heating Communication External display and operator module LCD Operating measured value display Error logbook Event list Slave pointer function Trace function Programmable control inputs and outputs Number of parameter sets Parameterization software (Softstarter ES) Power semiconductors (thyristors) Spring-loaded terminals Screw terminals UL/CSA CE marking Soft starting under heavy starting conditions Configuring support SIRIUS 3RW30/31 Standard applications 16 Soft starting/ramp-down Voltage ramp Starting/stopping voltage Starting and ramp-down time Torque control Starting/stopping torque Torque limit Ramp time • Reduction of the mechanical load in the operating mechanism • Considerable space savings and reduced wiring compared with mechanical reduced voltage starters • Maintenance-free switching • Very easy handling • Fits perfectly in the SIRIUS modular system Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-163 SIRIUS Soft Starters Standard Applications—SIRIUS 3RW3 Soft Starters Selection Selection and ordering data 3RW30 03-2CB54 3RW30 25-1AB14 3RW30 35-1AA12 3RW30 35-1AB14 Rated operating voltage Ue At ambient temperature 50 °C Rated operating current Ie Rated output of three-phase induction motors for rated operating voltage Ue Size 115 V 200 V 230 V 460 V 575 V V A hp hp hp hp hp Order No. List Price $ Weight per PU approx. kg Soft starters for easy starting conditions and high operating frequency 200 ... 400 2.6 - 0.5 0.5 - - 3RW30 03-@CB54 308.00 0.200 Order No. extension for rated connection method1)1 with screw-type terminals with spring-loaded terminals 22.5 mm 22.5 mm 1 2 Soft starters for three-phase asynchronous motors CONTROL PRODUCTS 16 200 ... 460 460 ... 575 4.8 7.8 - 1 2 1 2 3 5 - S00 S00 3RW30 14-1CB@4 3RW30 16-1CB@4 406.00 484.00 0.302 0.305 11 14 21 - 3 3 5 3 3 5 7.5 10 15 - S0 S0 S0 3RW30 24-1AB@4 3RW30 25-1AB@4 3RW30 26-1AB@4 496.00 567.00 587.00 0.490 0.481 0.489 27 32 38 - 7.5 7.5 10 7.5 10 10 20 20 25 - S2 S2 S2 3RW30 34-1AB@4 3RW30 35-1AB@4 3RW30 36-1AB@4 763.00 942.00 1177.00 0.794 0.779 0.791 54 64 85 - 15 20 25 20 20 30 40 40 60 - S3 S3 S3 3RW30 44-1AB@4 3RW30 45-1AB@4 3RW30 46-1AB@4 1301.00 1639.00 1978.00 1.660 1.800 1.810 11 14 21 - - - 7.5 10 15 10 10 15 S0 S0 S0 3RW30 24-1AB@5 3RW30 25-1AB@5 3RW30 26-1AB@5 668.00 723.00 780.00 0.490 0.489 0.489 27 32 38 - - - 20 20 25 25 30 30 S2 S2 S2 3RW30 34-1AB@5 3RW30 35-1AB@5 3RW30 36-1AB@5 916.00 1132.00 1412.00 0.791 0.793 0.792 54 64 85 - - - 40 40 60 50 60 75 S3 S3 S3 3RW30 44-1AB@5 3RW30 45-1AB@5 3RW30 46-1AB@5 1561.00 1967.00 2375.00 1.660 1.810 1.800 2) Order No. extension for rated control supply voltage Us AC/DC 24 V AC/DC 110 ... 230 V 0 1 Soft starters with two-ramp control for three-phase induction motors with two speeds (double pole-reversing) 200 ... 460 11 14 21 - 3 3 5 3 3 5 7.5 10 15 - S0 S0 S0 3RW31 24-1CB14 3RW31 25-1CB14 3RW31 26-1CB14 613.00 657.00 722.00 0.468 0.475 0.464 460 ... 575 11 14 21 - - - 7.5 10 15 10 10 15 S0 S0 S0 3RW31 24-1CB15 3RW31 25-1CB15 3RW31 26-1CB15 735.00 795.00 858.00 0.467 0.476 0.475 3 5 10 3 5 10 - - S0 S2 S3 3RW30 26-1AA12 3RW30 35-1AA12 3RW30 45-1AA12 313.00 501.00 864.00 0.439 0.729 1.390 Soft starters for single-phase motors Soft Starter Control 115 ... 240 21 32 64 1.5 2 5 1) Units have removable terminals. 2) 3RW30 46-1AB05 soft starters (AC/DC 24 V version): Delivery time on request. Selection of the soft starter depends on the motor’s rated current. 16-164 The SIRIUS 3RW3 solid-state soft starters are designed for easy starting conditions. JLoad < 10 x JMotor. In the event of deviating conditions or increased switching frequency, it may be necessary to choose a larger unit. Siemens recommends the use of the selection and simulation program Win-Soft starter. See Technical specifications for information about rated currents for ambient temperatures >50 °C. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule NEMA SIRIUS Soft Starters Standard Applications—SIRIUS 3RW40 Soft Starters Selection Overview Area of application SIRIUS 3RW40 SIRIUS 3RW40 soft starters have all the same advantages as the 3RW30/31 soft starters including soft start and soft stop,1) and internal bypass. At the same time they come with additional functions, i.e. selectable solid-state motor overload, intrinsic device protection and adjustable current limiting, as well as a new patented two-phase control method (Polarity Balancing) that is unique in this rating range. SIRIUS 3RW40 soft starters are part of the SIRIUS modular system. This results in advantages such as identical sizes and a uniform connection system. Thanks to their particularly compact design, SIRIUS 3RW40 soft starters are only half as big as comparable wye-delta starters. Hence they can be mounted in compact space requirements in the control cabinet. Configuring and installation are carried out quickly and easily thanks to the 3-wire connection. The SIRIUS 3RW40 solid-state soft starters are suitable for soft starting and stopping of three-phase asynchronous motors. Using the patented two-phase control, the current is kept at minimum values in all three phases throughout the entire starting time and typical direct current components are eliminated. This not only enables the two-phase starting of motors up to 300 Hp (at 460 V) but also avoids the current and torque peaks which occur i.e. with wye-delta starters or other mechanical starters. SIRIUS 3RW40 for three-phase motors Soft starters rated up to 300 Hp (at 460 V) for standard applications in three-phase power systems. Extremely small sizes, low power losses and simple commissioning are just three of the many advantages of the SIRIUS 3RW40 soft starters. Application areas • Fans • Pumps • Building/construction machines • Presses • Escalators • Transport systems • Air conditioning systems • Ventilators • Assembly lines • Compressors and coolers • Operating mechanisms Applicable standards • IEC 60947-2 • UL/CSA #E143112 A 200 V 230 V 460 V 575 V hp hp hp hp Size Order No. List Price $ Approx. weight per PU CONTROL PRODUCTS Ambient temperature 50 °C 3) Rated operating Rated output of three-phase induction motors for rated operating voltage Ue current Ie 16 3RW40 76-6BB44 3RW40 56-6BB44 Inline circuit, rated operating voltage 200 ... 460 V 117 145 30 40 40 50 75 100 – – S6 3RW40 55-@BB@4 3RW40 56-@BB@4 2237.00 2460.00 5.700 5.700 205 248 60 75 75 100 150 200 – – S12 3RW40 73-@BB@4 3RW40 74-@BB@4 2879.00 3243.00 7.000 7.000 315 385 100 125 125 1250 250 300 – – 3RW40 75-@BB@4 3RW40 76-@BB@4 3578.00 4585.00 7.000 7.000 Inline circuit, rated operating voltage 400 ... 600 V 117 145 – – – – 75 100 100 150 S6 3RW40 55-@BB@5 3RW40 56-@BB@5 2573.00 2829.00 5.700 5.700 205 248 – – – – 150 200 200 250 S12 3RW40 73-@BB@5 3RW40 74-@BB@5 3321.00 3735.00 7.000 7.000 315 385 – – – – 250 300 300 400 3RW40 75-@BB@5 3RW40 76-@BB@5 4115.00 5278.00 7.000 7.000 Order No. extension for connection method • with spring-loaded terminals • with screw-type terminals 2 6 Soft Starter Control Order No. extension for the rated control supply voltage Us 2) • 115 V AC • 230 V AC 3 4 1) Soft stop not available on 3RW31. 2) Control by way of the internal 24 V DC supply and direct control by means of PLC possible. 3) For other temperature ratings, see the Industrial Controls catalog CPPC-06000-0806. The SIRIUS 3RW40 solid-state soft starters are designed for easy starting conditions. JLoad < 10 x JMotor. In the event of deviating conditions or increased duty cycle, it may be necessary to choose a larger device. Siemens recommends the use of the selection and simulation program Win-SOFTSTARTER. Selection of the soft starter depends on the motor's rated current. Discount Schedule IEC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-165 SIRIUS Soft Starters High Feature Applications—SIRIUS 3RW44 Soft Starters Selection prompted, multi-line graphic display with background lighting. The optimized motor ramp-up and ramp-down can be effected by means of just a few settings with a previously selected language. Four-key operation and plain-text displays for each menu point guarantee full clarity at every moment of the parameterization and operation. Overview SIRIUS 3RW44 In addition to soft starting and soft stopping, the solid-state SIRIUS 3RW44 soft starters provide numerous functions for higher-level requirements. They cover a rating range up to 900Hp at 460 V in the inline circuit1). The SIRIUS 3RW44 soft starters are characterized by a compact design for space-saving and clearly arranged control cabinet layouts. For optimized motor starting and stopping, the innovative SIRIUS 3RW44 soft starters are an attractive alternative with considerable savings potential compared to applications with a frequency converter. The new torque control and adjustable current limiting enable these high feature soft starters to be used in nearly every conceivable task. They reliably mitigate the sudden torque applications and current peaks during motor starting and stopping. This creates savings potential when calculating the size of the controlgear and when servicing the machinery installed. Be it for inline circuits or inside-delta circuits – the SIRIUS 3RW44 soft starter offers savings especially in terms of size and equipment costs. Combinations of various starting, operating and ramp-down possibilities ensure an optimum adaptation to the applicationspecific requirements. Operating and commissioning can be performed by means of the user-friendly keypad and a menu- Applicable standards • IEC 60947-4-2 • UL/CSA #E143112 Area of application The SIRIUS 3RW44 solid-state soft starters are suitable for the torque-controlled soft starting and smooth ramp-down as well as braking of three-phase asynchronous motors. Application areas, e.g. • Pumps • Ventilators • Compressors • Water transport • Conveying systems and lifts • Hydraulics • Mills • Saws • Crushers • Mixers • Centrifuges • Industrial cooling and • refrigerating systems 1) Current range available up to 600Hp at 460 V. CONTROL PRODUCTS 16 Selection and ordering data 3RW44 36-6BC44 3RW44 27-1BC44 Ambient temperature 50 °C 3RW44 47-6BC44 1) Order No. Rated operating current Ie Rated output of three-phase induction motors for rated operating voltage Ue A 200 V hp 230 V hp 460 V hp List Price $ Approx. weight per PU 575 V hp kg Soft Starter Control Inline circuit, rated operating voltage 200 ... 460 V 26 7.5 7.5 15 32 10 10 20 42 10 15 25 51 15 15 30 68 20 20 50 82 25 25 60 Order No. extension for connection method • with spring-loaded terminals • with screw-type terminals 100 30 30 75 117 30 40 75 145 40 50 100 180 50 60 125 215 60 75 150 280 75 100 200 315 100 125 250 385 125 150 300 494 150 200 400 551 150 200 450 615 200 250 500 693 200 250 550 780 250 300 600 Order No. extension for connection method • with spring-loaded terminals • with screw-type terminals Order No. extension for the rated control supply voltage Us • 115 V AC • 230 V AC – – – – – – 3RW44 22-@ BC@ 4 3RW44 23-@ BC@ 4 3RW44 24-@ BC@ 4 3RW44 25-@ BC@ 4 3RW44 26-@ BC@ 4 3RW44 27-@ BC@ 4 2337.00 2472.00 2494.00 2963.00 3109.00 3735.00 4.900 4.900 4.900 4.900 4.900 4.900 – – – – – – – – – – – – – 3 1 3RW44 34-@ BC@ 4 3RW44 35-@ BC@ 4 3RW44 36-@ BC@ 4 3RW44 43-@ BC@ 4 3RW44 44-@ BC@ 4 3RW44 45-@ BC@ 4 3RW44 46-@ BC@ 4 3RW44 47-@ BC@ 4 3RW44 53-@ BC@ 4 3RW44 54-@ BC@ 4 3RW44 55-@ BC@ 4 3RW44 56-@ BC@ 4 3RW44 57-@ BC@ 4 4406.00 4652.00 6039.00 6565.00 6922.00 7503.00 8342.00 9282.00 10959.00 12580.00 13979.00 15656.00 19570.00 7.900 7.900 7.900 10.300 10.300 10.300 10.300 10.300 50.000 50.000 50.000 50.000 50.000 2 6 3 4 1) For other temperature ratings, see technical information in 2006 Industrial Catalog CPPC-06000-0106. 16-166 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule IEC SIRIUS Soft Starters High Feature Applications—SIRIUS 3RW44 Soft Starters Selection Selection and ordering data 3RW44 36-6BC44 3RW44 27-1BC44 3RW44 47-6BC44 Ambient temperature 50 °C 2) Order No. Rated operating current Ie Rated output of three-phase induction motors for rated operating voltage Ue 200 V 230 V 460 V 575 V A hp hp hp hp List Price $ Approx. weight per PU kg Inline circuit, rated operating voltage 400 ... 600 V 26 32 42 51 68 82 – – – – – – – – – – – – 15 20 25 30 50 60 20 25 30 40 50 75 3RW44 22-@BC@5 3RW44 23-@BC@5 3RW44 24-@BC@5 3RW44 25-@BC@5 3RW44 26-@BC@5 3RW44 27-@BC@5 2695.00 2852.00 2874.00 3410.00 3578.00 4305.00 4.900 4.900 4.900 4.900 4.900 4.900 Order No. extension for connection method • with spring-loaded terminals • with screw-type terminals 100 – 117 – 145 – – – – 75 75 100 75 100 125 3RW44 34-@BC@5 3RW44 35-@BC@5 3RW44 36-@BC@5 5077.00 5356.00 6945.00 7.900 7.900 7.900 180 215 280 315 385 – – – – – – – – – – 125 150 200 250 300 150 200 250 300 400 3RW44 43-@BC@5 3RW44 44-@BC@5 3RW44 45-@BC@5 3RW44 46-@BC@5 3RW44 47-@BC@5 7559.00 7962.00 8633.00 9595.00 10680.00 10.300 10.300 10.300 10.300 10.300 494 551 615 693 780 – – – – – – – – – – 400 450 500 550 600 500 550 600 700 800 3RW44 53-@BC@4 3RW44 54-@BC@4 3RW44 55-@BC@4 3RW44 56-@BC@4 3RW44 57-@BC@4 12603.00 14470.00 16081.00 18004.00 22510.00 50,000 50,000 50,000 50,000 50,000 3 1 16 CONTROL PRODUCTS Order No. extension for connection method • with spring-loaded terminals • with screw-type terminals 2 6 Order No. extension for the rated control supply voltage Us1) • 115 V AC • 230 V AC 1) Control by way of the internal 24 V DC supply and direct control by means of PLC possible. 2) For other temperature ratings, see technical information in the Industrial Controls Catalog CPPC-06000-0803. Soft starter selection depends on the motor's rated current. 3 4 The 3RW44 solid-state soft starters are designed for normal starting (class 10). (Inertia load of the overall operating mechanism JLoad < 10 x JMotor; starting current 350 % x Ie for 20 s or similar load.) For any other conditions of use, the devices should be selected using the selection and simulation program Win-SOFTSTARTER. See technical specifications for information about rated currents for ambient temperatures > 40 °C and operating frequency. Soft Starter Control Discount Schedule IEC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-167 Control Products Enclosed 3RW40 Selection Ordering Information 3RW40 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Voltage ramp up and ramp down ▪ Current limit adjustment of 125 - 550% ▪ Internal overload class 10, 15, or 20 ▪ Internal self protection ▪ Fault monitoring 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW40 is designed for normal starting applications (Class 10 applications). 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 73 non-combination starters include: ▪ NEMA rated enclosure ▪ 3RW40 Sirius softstarter with built-in OL and bypass ▪ Control circuit transformer ▪ Line side power terminal block ▪ Reset button Ideal applications for 3RW40 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Building/construction machines ▪ Presses ▪ Escalators ▪ Transport systems ▪ Air conditioning systems ▪ Ventilators ▪ Assembly lines ▪ Compressors and chillers The 3RW40 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 73 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW40 for Standard Applications CONTROL PRODUCTS 16 Enclosed Non-Combination (Starter Only) Rated Operating Current 117 145 205 248 315 385 117 145 205 248 315 385 MAX HP Class 10 Light Duty (350% * Ie for 10s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 30 40 75 — 56 3RW4055-6BB34 73AS3_BFA 4700.00 40 50 100 — 75 3RW4056-6BB34 73BS3_BFA 5100.00 60 75 150 — 112 3RW4073-6BB34 73CS3_BFA 5700.00 75 100 200 — 149 3RW4074-6BB34 73DS3_BFA 6100.00 100 125 250 — 186 3RW4075-6BB34 73ES3_BFA 6800.00 125 150 300 — 224 3RW4076-6BB34 73FS3_BFA 8900.00 KW List Price $ 4700.00 5200.00 5600.00 6100.00 6800.00 8900.00 NEMA 12 73AS3_0FA 73BS3_0FA 73CS3_0FA 73DS3_0FA 73ES3_0FA 73FS3_0FA 5000.00 5500.00 6200.00 6700.00 7500.00 9800.00 6 2 3 4 73AS35DFA 73BS35DFA 73CS35DFA 73DS35DFA 73ES35DFA 73FS35DFA Class 20 Severe Duty (350% * Ie for 20s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 30 40 75 — 56 3RW4055-6BB34 73AS3_BFA 4700.00 40 50 100 — 75 3RW4056-6BB34 73BS3_BFA 5100.00 60 60 125 — 93 3RW4073-6BB34 73CS3_BFA 5700.00 60 75 150 — 112 3RW4074-6BB34 73DS3_BFA 6100.00 75 100 200 — 149 3RW4075-6BB34 73ES3_BFA 6800.00 100 125 250 — 186 3RW4076-6BB34 73FS3_BFA 8900.00 NEMA 3R 73AS3_DFA 73BS3_DFA 73CS3_DFA 73DS3_DFA 73ES3_DFA 73FS3_DFA — — — — — — — — — — — — 75 100 150 200 250 300 100 150 200 250 300 400 — — — — — — 200V 230V 380V 460V 3RW4055-6BB35 3RW4056-6BB35 3RW4073-6BB35 3RW4074-6BB35 3RW4075-6BB35 3RW4076-6BB35 6 2 3 4 73AS35BFA 73BS35BFA 73CS35BFA 73DS35BFA 73ES35BFA 73FS35BFA NEMA 3R 73AS3_DFA 73BS3_DFA 73CS3_DFA 73DS3_DFA 73ES3_DFA 73FS3_DFA List Price $ 4700.00 5100.00 5700.00 6100.00 6800.00 8900.00 NEMA 4 73AS3_EFA 73BS3_EFA 73CS3_EFA 73DS3_EFA 73ES3_EFA 73FS3_EFA List Price $ 5000.00 5400.00 6000.00 6500.00 7200.00 9400.00 5100.00 5600.00 6200.00 6600.00 7200.00 9800.00 6 2 3 4 73AS350FA 73BS350FA 73CS350FA 73DS350FA 73ES350FA 73FS350FA List Price $ 4700.00 5200.00 5600.00 6100.00 6800.00 8900.00 NEMA 12 73AS3_0FA 73BS3_0FA 73CS3_0FA 73DS3_0FA 73ES3_0FA 73FS3_0FA 5100.00 5600.00 6200.00 6600.00 7200.00 9800.00 6 2 3 4 73AS350FA 73BS350FA 73CS350FA 73DS350FA 73ES350FA 73FS350FA NEMA 4/4X 73AS3_WFA 73BS3_WFA 73CS3_WFA 73DS3_WFA 73ES3_WFA 73FS3_WFA List Price $ 5800.00 6300.00 6800.00 7300.00 7900.00 11800.00 5000.00 5500.00 6200.00 6700.00 7500.00 9800.00 6 2 3 4 73AS35EFA 73BS35EFA 73CS35EFA 73DS35EFA 73ES35EFA 73FS35EFA 5100.00 5800.00 6600.00 7100.00 7900.00 10300.00 6 2 3 4 73AS35WFA 73BS35WFA 73CS35WFA 73DS35WFA 73ES35WFA 73FS35WFA 6200.00 6700.00 7400.00 7800.00 8600.00 12600.00 List Price $ 4700.00 5100.00 5700.00 6100.00 6800.00 8900.00 NEMA 4 73AS3_EFA 73BS3_EFA 73CS3_EFA 73DS3_EFA 73ES3_EFA 73FS3_EFA List Price $ 5000.00 5400.00 6000.00 6500.00 7200.00 9400.00 73AS3_WFA 73BS3_WFA 73CS3_WFA 73DS3_WFA 73ES3_WFA 73FS3_WFA List Price $ 5800.00 6300.00 6800.00 7300.00 7900.00 11800.00 5000.00 5500.00 6200.00 6700.00 7500.00 9800.00 6 2 3 4 73AS35EFA 73BS35EFA 73CS35EFA 73DS35EFA 73ES35EFA 73FS35EFA 5100.00 5800.00 6600.00 7100.00 7900.00 10300.00 6 2 3 4 73AS35WFA 73BS35WFA 73CS35WFA 73DS35WFA 73ES35WFA 73FS35WFA 6200.00 6700.00 7400.00 7800.00 8600.00 12600.00 Stainless Steel Soft Starter Control Enclosed Non-Combination (Starter Only) Rated Operating Current 112 132 185 205 280 340 112 132 185 205 280 340 MAX HP — — — — — — Starter — — — — — — KW 75 100 125 150 200 250 75 125 150 200 250 300 — — — — — — 200V 230V 380V 460V 3RW4055-6BB35 3RW4056-6BB35 3RW4073-6BB35 3RW4074-6BB35 3RW4075-6BB35 3RW4076-6BB35 6 2 3 4 73AS35BFA 73BS35BFA 73CS35BFA 73DS35BFA 73ES35BFA 73FS35BFA 5000.00 5500.00 6200.00 6700.00 7500.00 9800.00 6 2 3 4 73AS35DFA 73BS35DFA 73CS35DFA 73DS35DFA 73ES35DFA 73FS35DFA size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. 16-168 Starter NEMA 4/4X Stainless Steel selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule IEC Control Products Enclosed 3RW40 Selection Ordering Information 3RW40 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Voltage ramp up and ramp down ▪ Current limit adjustment of 125 - 550% ▪ Internal overload class 10, 15, or 20 ▪ Internal self protection ▪ Fault monitoring 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW40 is designed for normal starting applications (Class 10 applications). 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 74 non-combination starters include: ▪ NEMA rated enclosure ▪ Circuit breaker disconnect with shunt trip ▪ 3RW40 Sirius softstarter with built-in OL and bypass ▪ Control circuit transformer Ideal applications for 3RW40 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Building/construction machines ▪ Presses ▪ Escalators ▪ Transport systems ▪ Air conditioning systems ▪ Ventilators ▪ Assembly lines ▪ Compressors and chillers The 3RW40 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 74 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW40 for Standard Applications Enclosed Circuit Breaker Combination (Starter with Circuit Breaker Disconnect) Class 10 Light Duty (350% * Ie for 10s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAP 6300.00 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAP 6900.00 60 75 150 — 112 3RW4073-6BB34 74CS3_BFAP 8100.00 75 100 200 — 149 3RW4074-6BB34 74DS3_BFAP 8500.00 100 125 250 — 186 3RW4075-6BB34 74ES3_BFAP 10700.00 125 150 300 — 224 3RW4076-6BB34 74FS3_BFAP 12200.00 — — — — — — — — — — — — KW 75 100 150 200 250 300 100 150 200 250 300 400 — — — — — — 200V 230V 380V 460V 3RW4055-6BB35 3RW4056-6BB35 3RW4073-6BB35 3RW4074-6BB35 3RW4075-6BB35 3RW4076-6BB35 6 2 3 4 74AS35BFAP 74BS35BFAP 74CS35BFAP 74DS35BFAP 74ES35BFAP 74FS35BFAP 6700.00 7300.00 8300.00 9100.00 11400.00 12200.00 List NEMA 3R Price $ 74AS3_DFAP 6300.00 74BS3_DFAP 6900.00 74CS3_DFAP 8100.00 74DS3_DFAP 8500.00 74ES3_DFAP 10700.00 74FS3_DFAP 12200.00 List NEMA 12 Price $ 74AS3_0FAP 6300.00 74BS3_0FAP 6900.00 74CS3_0FAP 8100.00 74DS3_0FAP 8500.00 74ES3_0FAP 10700.00 74FS3_0FAP 12200.00 List NEMA 4 Price $ 74AS3_EFAP 6700.00 74BS3_EFAP 7300.00 74CS3_EFAP 8600.00 74DS3_EFAP 9000.00 74ES3_EFAP 11300.00 74FS3_EFAP 12900.00 NEMA 4/4X List Price $ 74AS3_WFAP 9500.00 74BS3_WFAP 10100.00 6 2 3 4 74AS35DFAP 6600.00 74BS35DFAP 7300.00 74CS35DFAP 8600.00 74DS35DFAP 9000.00 74ES35DFAP 11400.00 74FS35DFAP 12200.00 6 2 3 4 74AS350FAP 6600.00 74BS350FAP 7300.00 74CS350FAP 8600.00 74DS350FAP 9000.00 74ES350FAP 11400.00 74FS350FAP 12200.00 6 2 3 4 74AS35EFAP 7000.00 74BS35EFAP 7700.00 74CS35EFAP 9100.00 74DS35EFAP 9500.00 74ES35EFAP 12000.00 74FS35EFAP 13800.00 6 2 3 4 74AS35WFAP 9900.00 74BS35WFAP 10600.00 Stainless Steel CONTROL PRODUCTS 117 145 205 248 315 385 MAX HP 16 Rated Operating Current 117 145 205 248 315 385 Enclosed Circuit Breaker Combination (Starter with Circuit Breaker Disconnect) 112 132 185 205 280 340 MAX HP Class 20 Severe Duty (350% * Ie for 20s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAP 6300.00 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAP 6900.00 60 60 125 — 93 3RW4073-6BB34 74CS3_BFAP 8100.00 60 75 150 — 112 3RW4074-6BB34 74DS3_BFAP 8500.00 75 100 200 — 149 3RW4075-6BB34 74ES3_BFAP 10700.00 100 125 250 — 186 3RW4076-6BB34 74FS3_BFAP 12200.00 — — — — — — — — — — — — KW 75 100 125 150 200 250 75 125 150 200 250 300 — — — — — — Starter 200V 230V 380V 460V 3RW4055-6BB35 3RW4056-6BB35 3RW4073-6BB35 3RW4074-6BB35 3RW4075-6BB35 3RW4076-6BB35 6 2 3 4 74AS35BFAP 6700.00 74BS35BFAP 7300.00 74CS35BFAP 8300.00 74DS35BFAP 9100.00 74ES35BFAP 11400.00 74FS35BFAP 12200.00 List NEMA 3R Price $ 74AS3_DFAP 6300.00 74BS3_DFAP 6900.00 74CS3_DFAP 8100.00 74DS3_DFAP 8500.00 74ES3_DFAP 10700.00 74FS3_DFAP 12200.00 List NEMA 12 Price $ 74AS3_0FAP 6300.00 74BS3_0FAP 6900.00 74CS3_0FAP 8100.00 74DS3_0FAP 8500.00 74ES3_0FAP 10700.00 74FS3_0FAP 12200.00 List NEMA 4 Price $ 74AS3_EFAP 6700.00 74BS3_EFAP 7300.00 74CS3_EFAP 8600.00 74DS3_EFAP 9000.00 74ES3_EFAP 11300.00 74FS3_EFAP 12900.00 List Price $ 74AS3_WFAP 9500.00 74BS3_WFAP 10100.00 6 2 3 4 74AS35DFAP 6600.00 74BS35DFAP 7300.00 74CS35DFAP 8600.00 74DS35DFAP 9000.00 74ES35DFAP 11400.00 74FS35DFAP 12200.00 6 2 3 4 74AS350FAP 6600.00 74BS350FAP 7300.00 74CS350FAP 8600.00 74DS350FAP 9000.00 74ES350FAP 11400.00 74FS350FAP 12200.00 6 2 3 4 74AS35EFAP 7000.00 74BS35EFAP 7700.00 74CS35EFAP 9100.00 74DS35EFAP 9500.00 74ES35EFAP 12000.00 74FS35EFAP 13800.00 6 2 3 4 74AS35WFAP 9900.00 74BS35WFAP 10600.00 size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. Discount Schedule IEC Starter NEMA 4/4X Stainless Steel selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-169 Soft Starter Control Rated Operating Current 112 132 185 205 280 340 Control Products Enclosed 3RW40 Selection Ordering Information 3RW40 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Voltage ramp up and ramp down ▪ Current limit adjustment of 125 - 550% ▪ Internal overload class 10, 15, or 20 ▪ Internal self protection ▪ Fault monitoring 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW40 is designed for normal starting applications (Class 10 applications). 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 74 combination starters include: ▪ NEMA rated enclosure ▪ Fusible disconnect ▪ 3RW40 Sirius softstarter with built-in OL and bypass ▪ Control circuit transformer Ideal applications for 3RW40 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Building/construction machines ▪ Presses ▪ Escalators ▪ Transport systems ▪ Air conditioning systems ▪ Ventilators ▪ Assembly lines ▪ Compressors and chillers The 3RW40 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 74 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW40 for Standard Applications CONTROL PRODUCTS 16 Enclosed Fusible Combination (Starter with Fusible Disconnect) Rated Operating Current 117 145 205 248 315 385 117 145 205 248 315 385 MAX HP Class 10 Light Duty (350% * Ie for 10s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAF 5700.00 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAF 7200.00 60 75 150 — 112 3RW4073-6BB34 74CS3_BFAF 8300.00 75 100 200 — 149 3RW4074-6BB34 74DS3_BFAF 8700.00 100 125 250 — 186 3RW4075-6BB34 74ES3_BFAF 10900.00 125 150 300 — 224 3RW4076-6BB34 74FS3_BFAF 12300.00 — — — — — — — — — — — — KW 75 100 150 200 250 300 100 150 200 250 300 400 — — — — — — 200V 230V 380V 460V 3RW4055-6BB35 3RW4056-6BB35 3RW4073-6BB35 3RW4074-6BB35 3RW4075-6BB35 3RW4076-6BB35 6 2 3 4 74AS35BFAF 6100.00 74BS35BFAF 7700.00 74CS35BFAF 8500.00 74DS35BFAF 9200.00 74ES35BFAF 11600.00 74FS35BFAF 12200.00 List NEMA 3R Price $ 74AS3_DFAF 5700.00 74BS3_DFAF 7200.00 74CS3_DFAF 8200.00 74DS3_DFAF 8700.00 74ES3_DFAF 10900.00 74FS3_DFAF 12400.00 List NEMA 12 Price $ 74AS3_0FAF 5700.00 74BS3_0FAF 7200.00 74CS3_0FAF 8200.00 74DS3_0FAF 8700.00 74ES3_0FAF 10900.00 74FS3_0FAF 12300.00 List NEMA 4 Price $ 74AS3_EFAF 6000.00 74BS3_EFAF 7600.00 74CS3_EFAF 8700.00 74DS3_EFAF 9200.00 74ES3_EFAF 11500.00 74FS3_EFAF 13000.00 NEMA 4/4X List Price $ 74AS3_WFAF 8900.00 74BS3_WFAF 10400.00 6 2 3 4 74AS35DFAF 6000.00 74BS35DFAF 7600.00 74CS35DFAF 8800.00 74DS35DFAF 9200.00 74ES35DFAF 11600.00 74FS35DFAF 12200.00 6 2 3 4 74AS350FAF 6100.00 74BS350FAF 7700.00 74CS350FAF 8800.00 74DS350FAF 9200.00 74ES350FAF 11600.00 74FS350FAF 12200.00 6 2 3 4 74AS35EFAF 6300.00 74BS35EFAF 8000.00 74CS35EFAF 9300.00 74DS35EFAF 9700.00 74ES35EFAF 12200.00 74FS35EFAF 13900.00 6 2 3 4 74AS35WFAF 9300.00 74BS35WFAF 10900.00 List NEMA 3R Price $ 74AS3_DFAF 5700.00 74BS3_DFAF 7200.00 74CS3_DFAF 8200.00 74DS3_DFAF 8700.00 74ES3_DFAF 10900.00 74FS3_DFAF 12400.00 List NEMA 12 Price $ 74AS3_0FAF 5700.00 74BS3_0FAF 7200.00 74CS3_0FAF 8200.00 74DS3_0FAF 8700.00 74ES3_0FAF 10900.00 74FS3_0FAF 12300.00 List NEMA 4 Price $ 74AS3_EFAF 6000.00 74BS3_EFAF 7600.00 74CS3_EFAF 8700.00 74DS3_EFAF 9200.00 74ES3_EFAF 11500.00 74FS3_EFAF 13000.00 List Price $ 74AS3_WFAF 8900.00 74BS3_WFAF 10400.00 6 2 3 4 74AS35DFAF 6000.00 74BS35DFAF 7600.00 74CS35DFAF 8800.00 74DS35DFAF 9200.00 74ES35DFAF 11600.00 74FS35DFAF 12200.00 6 2 3 4 74AS350FAF 6100.00 74BS350FAF 7700.00 74CS350FAF 8800.00 74DS350FAF 9200.00 74ES350FAF 11600.00 74FS350FAF 12200.00 6 2 3 4 74AS35EFAF 6300.00 74BS35EFAF 8000.00 74CS35EFAF 9300.00 74DS35EFAF 9700.00 74ES35EFAF 12200.00 74FS35EFAF 13900.00 6 2 3 4 74AS35WFAF 9300.00 74BS35WFAF 10900.00 Stainless Steel Soft Starter Control Enclosed Fusible Combination (Starter with Fusible Disconnect) Rated Operating Current 112 132 185 205 280 340 112 132 185 205 280 340 MAX HP Class 20 Severe Duty (350% * Ie for 20s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAF 5700.00 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAF 7200.00 60 60 125 — 93 3RW4073-6BB34 74CS3_BFAF 8300.00 60 75 150 — 112 3RW4074-6BB34 74DS3_BFAF 8700.00 75 100 200 — 149 3RW4075-6BB34 74ES3_BFAF 10900.00 100 125 250 — 186 3RW4076-6BB34 74FS3_BFAF 12300.00 — — — — — — Starter — — — — — — KW 75 100 125 150 200 250 75 125 150 200 250 300 — — — — — — 200V 230V 380V 460V 3RW4055-6BB35 3RW4056-6BB35 3RW4073-6BB35 3RW4074-6BB35 3RW4075-6BB35 3RW4076-6BB35 6 2 3 4 74AS35BFAF 6100.00 74BS35BFAF 7700.00 74CS35BFAF 8500.00 74DS35BFAF 9200.00 74ES35BFAF 11600.00 74FS35BFAF 12200.00 size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. 16-170 Starter NEMA 4/4X Stainless Steel selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule IEC Control Products Enclosed 3RW44 Selection Ordering Information 3RW44 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Multiple starting/stopping techniques including torque control ▪ Internal overload class 5, 10, 15, 20, or 30 ▪ Built-in graphical LCD keypad ▪ Internal self protection ▪ Fault monitoring ▪ 3 parameter sets ▪ Communication capable via opt. Profibus module ▪ Programmable inputs and outputs ▪ External keypad available 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW44 is designed for normal starting applications. 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 73 non-combination starters include: ▪ NEMA rated enclosure ▪ 3RW44 Sirius softstarter with built-in OL and bypass ▪ Control circuit transformer Ideal applications for 3RW44 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Conveying systems and lifts ▪ Hydraulics ▪ Machine tools ▪ Mills saws ▪ Crushers and grinders ▪ Mixers ▪ HVAC systems The 3RW44 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 73 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW44 For High Feature Applications Enclosed Non-Combination (Starter Only) MAX HP Class 10 Light Duty (350% * Ie for 10s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 7.5 7.5 15 — 12 3RW4422-1BC34 73AT3_BFA 3800.00 10 10 20 — 15 3RW4423-1BC34 73BT3_BFA 4000.00 10 15 25 — 19 3RW4424-1BC34 73CT3_BFA 4300.00 15 15 30 — 22 3RW4425-1BC34 73DT3_BFA 4600.00 20 25 50 — 37 3RW4426-1BC34 73ET3_BFA 4800.00 25 30 60 — 45 3RW4427-1BC34 73FT3_BFA 5200.00 30 30 75 — 56 3RW4434-6BC34 73GT3_BFA 6100.00 30 40 75 — 56 3RW4435-6BC34 73HT3_BFA 6800.00 40 50 100 — 75 3RW4436-6BC34 73JT3_BFA 7600.00 60 60 125 — 93 3RW4443-6BC34 73KT3_BFA 8800.00 60 75 150 — 112 3RW4444-6BC34 73LT3_BFA 9600.00 75 100 200 — 149 3RW4445-6BC34 73MT3_BFA 11900.00 100 125 250 — 186 3RW4446-6BC34 73NT3_BFA 13300.00 125 150 300 — 224 3RW4447-6BC34 73PT3_BFA 15000.00 150 200 400 — 298 3RW4453-6BC34 73QT_BFA 150 200 450 — 336 3RW4454-6BC34 73RT_BFA 200 250 500 — 373 3RW4455-6BC34 73ST_BFA 200 250 550 — 3RW4456-6BC34 73TT_BFA 200 250 600 — 447 3RW4457-6BC34 73WT_BFA KW List Price $ 3700.00 3900.00 4300.00 4500.00 4800.00 5300.00 6100.00 6800.00 7600.00 8800.00 9600.00 11800.00 13300.00 14900.00 NEMA 12 73AT3_0FA 73BT3_0FA 73CT3_0FA 73DT3_0FA 73ET3_0FA 73FT3_0FA 73GT3_0FA 73HT3_0FA 73JT3_0FA 73KT3_0FA 73LT3_0FA 73MT3_0FA 73NT3_0FA 73PT3_0FA 73QT_0FA 73RT_0FA 73ST_0FA 73TT_0FA 73WT_0FA List Price $ 3800.00 4000.00 4300.00 4600.00 4800.00 5200.00 6000.00 6700.00 7600.00 8800.00 9600.00 11800.00 13300.00 14900.00 NEMA 4 73AT3_EFA 73BT3_EFA 73CT3_EFA 73DT3_EFA 73ET3_EFA 73FT3_EFA 73GT3_EFA 73HT3_EFA 73JT3_EFA 73KT3_EFA 73LT3_EFA 73MT3_EFA 73NT3_EFA 73PT3_EFA 73QT_EFA 73RT_EFA 73ST_EFA 73TT_EFA 73WT_EFA List Price $ 3900.00 4200.00 4600.00 4900.00 5100.00 5500.00 6300.00 7100.00 8000.00 9300.00 10100.00 12400.00 13900.00 15700.00 NEMA 4/4X List Price $ 73AT3_WFA 4200.00 73BT3_WFA 4400.00 73CT3_WFA 4800.00 73DT3_WFA 5000.00 73ET3_WFA 5200.00 73FT3_WFA 6400.00 73GT3_WFA 7100.00 73HT3_WFA 7900.00 73JT3_WFA 8700.00 73KT3_WFA 9900.00 73LT3_WFA 10800.00 73MT3_WFA 14700.00 73NT3_WFA 16100.00 73PT3_WFA 17800.00 Stainless Steel CONTROL PRODUCTS NEMA 3R 73AT3_DFA 73BT3_DFA 73CT3_DFA 73DT3_DFA 73ET3_DFA 73FT3_DFA 73GT3_DFA 73HT3_DFA 73JT3_DFA 73KT3_DFA 73LT3_DFA 73MT3_DFA 73NT3_DFA 73PT3_DFA 73QT_DFA 73RT_DFA 73ST_DFA 73TT_DFA 73WT_DFA 16 Rated Operating Current 26 32 42 51 68 82 100 117 145 180 215 280 315 385 494 551 615 693 780 AVAILABILITY TO BE ANNOUNCED — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 15 20 25 30 50 60 75 75 100 125 150 200 250 300 400 450 500 550 600 20 25 30 40 50 75 75 100 125 150 200 250 300 400 500 600 700 750 850 — — — — — — — — — — — — — — — — — — — 6 2 3 4 73AT35BFA 73BT35BFA 73CT35BFA 73DT35BFA 73ET35BFA 73FT35BFA 73GT35BFA 73HT35BFA 73JT35BFA 73KT35BFA 73LT35BFA 73MT35BFA 73NT35BFA 73PT35BFA 73QT35BFA 73RT35BFA 73ST35BFA 73TT35BFA 73WT35BFA 4000.00 4300.00 4700.00 5000.00 5300.00 5700.00 6600.00 7400.00 8400.00 9700.00 10700.00 13100.00 14800.00 16600.00 6 2 3 4 73AT35DFA 73BT35DFA 73CT35DFA 73DT35DFA 73ET35DFA 73FT35DFA 73GT35DFA 73HT35DFA 73JT35DFA 73KT35DFA 73LT35DFA 73MT35DFA 73NT35DFA 73PT35DFA 73QT35DFA 73RT35DFA 73ST35DFA 73TT35DFA 73WT35DFA 4000.00 4300.00 4600.00 4900.00 5200.00 5800.00 6700.00 7500.00 8400.00 9600.00 10600.00 13100.00 14700.00 16600.00 6 2 3 4 73AT350FA 73BT350FA 73CT350FA 73DT350FA 73ET350FA 73FT350FA 73GT350FA 73HT350FA 73JT350FA 73KT350FA 73LT350FA 73MT350FA 73NT350FA 73PT350FA 73QT350FA 73RT350FA 73ST350FA 73TT350FA 73WT350FA 4000.00 4300.00 4700.00 4900.00 5300.00 5700.00 6600.00 7400.00 8400.00 9700.00 10700.00 13100.00 14700.00 16600.00 6 2 3 4 73AT35EFA 73BT35EFA 73CT35EFA 73DT35EFA 73ET35EFA 73FT35EFA 73GT35EFA 73HT35EFA 73JT35EFA 73KT35EFA 73LT35EFA 73MT35EFA 73NT35EFA 73PT35EFA 73QT35EFA 73RT35EFA 73ST35EFA 73TT35EFA 73WT35EFA 4200.00 4600.00 5000.00 5300.00 5600.00 6000.00 7000.00 7800.00 8900.00 10200.00 11300.00 13800.00 15500.00 17500.00 6 2 3 4 73AT35WFA 73BT35WFA 73CT35WFA 73DT35WFA 73ET35WFA 73FT35WFA 73GT35WFA 73HT35WFA 73JT35WFA 73KT35WFA 73LT35WFA 73MT35WFA 73NT35WFA 73PT35WFA 4400.00 4700.00 5100.00 5400.00 5700.00 6900.00 7700.00 8500.00 9500.00 10800.00 11800.00 16000.00 17600.00 19500.00 AVAILABILITY TO BE ANNOUNCED Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. Discount Schedule IEC Starter selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-171 Soft Starter Control 26 32 42 51 68 82 100 117 145 180 215 280 315 385 494 551 615 693 780 200V 230V 380V 460V 3RW4422-1BC35 3RW4423-1BC35 3RW4424-1BC35 3RW4425-1BC35 3RW4426-1BC35 3RW4427-1BC35 3RW4434-6BC35 3RW4435-6BC35 3RW4436-6BC35 3RW4443-6BC35 3RW4444-6BC35 3RW4445-6BC35 3RW4446-6BC35 3RW4447-6BC35 3RW4453-6BC35 3RW4454-6BC35 3RW4455-6BC35 3RW4456-6BC35 3RW4457-6BC35 Control Products Enclosed 3RW44 Selection Ordering Information 3RW44 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Multiple starting/stopping techniques including torque control ▪ Internal overload class 10, 15, or 20 ▪ Built-in graphical LCD keypad ▪ Internal self protection ▪ Fault monitoring ▪ 3 parameter sets ▪ Communication capable via opt. Profibus module ▪ Programmable inputs and outputs ▪ External keypad available 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW44 is designed for normal starting applications. 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 73 non-combination starters include: ▪ NEMA rated enclosure ▪ 3RW44 Sirius softstarter with built-in OL and bypass ▪ Control circuit transformer ▪ Line side power terminal block ▪ Reset button Ideal applications for 3RW44 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Conveying systems and lifts ▪ Hydraulics ▪ Machine tools ▪ Mills saws ▪ Crushers and grinders ▪ Mixers ▪ HVAC systems The 3RW44 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 73 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW44 For High Feature Applications CONTROL PRODUCTS 16 Enclosed Non-Combination (Starter Only) Rated Operating Current 26 32 42 51 68 82 97 113 134 175 195 243 263 326 494 551 615 634 650 MAX HP Class 20 Severe Duty (350% * Ie for 20s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 7.5 7.5 15 — 12 3RW4422-1BC34 73AT3_BFA 3800.00 10 10 20 — 15 3RW4423-1BC34 73BT3_BFA 4000.00 10 15 25 — 19 3RW4424-1BC34 73CT3_BFA 4300.00 15 15 30 — 22 3RW4425-1BC34 73DT3_BFA 4600.00 20 25 50 — 37 3RW4426-1BC34 73ET3_BFA 4800.00 25 30 60 — 45 3RW4427-1BC34 73FT3_BFA 5200.00 30 30 60 — 45 3RW4434-6BC34 73GT3_BFA 6100.00 30 40 75 — 56 3RW4435-6BC34 73HT3_BFA 6800.00 40 50 75 — 56 3RW4436-6BC34 73JT3_BFA 7600.00 50 60 100 — 75 3RW4443-6BC34 73KT3_BFA 8800.00 60 75 125 — 93 3RW4444-6BC34 73LT3_BFA 9600.00 75 75 150 — 112 3RW4445-6BC34 73MT3_BFA 11900.00 75 100 200 — 149 3RW4446-6BC34 73NT3_BFA 13300.00 100 125 250 — 186 3RW4447-6BC34 73PT3_BFA 15000.00 150 150 400 — 298 3RW4453-6BC34 73QT_BFA 150 200 450 — 336 3RW4454-6BC34 73RT_BFA 200 200 500 — 373 3RW4455-6BC34 73ST_BFA 200 250 500 — 373 3RW4456-6BC34 73TT_BFA 200 250 550 — 373 3RW4457-6BC34 73WT_BFA KW NEMA 3R 73AT3_DFA 73BT3_DFA 73CT3_DFA 73DT3_DFA 73ET3_DFA 73FT3_DFA 73GT3_DFA 73HT3_DFA 73JT3_DFA 73KT3_DFA 73LT3_DFA 73MT3_DFA 73NT3_DFA 73PT3_DFA 73QT_DFA 73RT_DFA 73ST_DFA 73TT_DFA 73WT_DFA List Price $ 3700.00 3900.00 4300.00 4500.00 4800.00 5300.00 6100.00 6800.00 7600.00 8800.00 9600.00 11800.00 13300.00 14900.00 NEMA 12 73AT3_0FA 73BT3_0FA 73CT3_0FA 73DT3_0FA 73ET3_0FA 73FT3_0FA 73GT3_0FA 73HT3_0FA 73JT3_0FA 73KT3_0FA 73LT3_0FA 73MT3_0FA 73NT3_0FA 73PT3_0FA 73QT_0FA 73RT_0FA 73ST_0FA 73TT_0FA 73WT_0FA List Price $ 3800.00 4000.00 4300.00 4600.00 4800.00 5200.00 6000.00 6700.00 7600.00 8800.00 9600.00 11800.00 13300.00 14900.00 NEMA 4 73AT3_EFA 73BT3_EFA 73CT3_EFA 73DT3_EFA 73ET3_EFA 73FT3_EFA 73GT3_EFA 73HT3_EFA 73JT3_EFA 73KT3_EFA 73LT3_EFA 73MT3_EFA 73NT3_EFA 73PT3_EFA 73QT_EFA 73RT_EFA 73ST_EFA 73TT_EFA 73WT_EFA List Price $ 3900.00 4200.00 4600.00 4900.00 5100.00 5500.00 6300.00 7100.00 8000.00 9300.00 10100.00 12400.00 13900.00 15700.00 NEMA 4/4X List Price $ 73AT3_WFA 4200.00 73BT3_WFA 4400.00 73CT3_WFA 4800.00 73DT3_WFA 5000.00 73ET3_WFA 5200.00 73FT3_WFA 6400.00 73GT3_WFA 7100.00 73HT3_WFA 7900.00 73JT3_WFA 8700.00 73KT3_WFA 9900.00 73LT3_WFA 10800.00 73MT3_WFA 14700.00 73NT3_WFA 16100.00 73PT3_WFA 17800.00 Stainless Steel Soft Starter Control AVAILABILITY TO BE ANNOUNCED 26 32 42 51 68 82 97 113 134 175 195 243 263 326 494 551 615 693 780 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 15 20 25 30 50 60 60 75 75 100 125 150 200 250 400 450 500 550 600 20 25 30 40 50 75 75 100 125 150 200 200 250 300 500 550 600 650 700 — — — — — — — — — — — — — — — — — — — 200V 230V 380V 460V 3RW4422-1BC35 3RW4423-1BC35 3RW4424-1BC35 3RW4425-1BC35 3RW4426-1BC35 3RW4427-1BC35 3RW4434-6BC35 3RW4435-6BC35 3RW4436-6BC35 3RW4443-6BC35 3RW4444-6BC35 3RW4445-6BC35 3RW4446-6BC35 3RW4447-6BC35 3RW4453-6BC35 3RW4454-6BC35 3RW4455-6BC35 3RW4456-6BC35 3RW4457-6BC35 6 2 3 4 73AT35BFA 73BT35BFA 73CT35BFA 73DT35BFA 73ET35BFA 73FT35BFA 73GT35BFA 73HT35BFA 73JT35BFA 73KT35BFA 73LT35BFA 73MT35BFA 73NT35BFA 73PT35BFA 73QT35BFA 73RT35BFA 73ST35BFA 73TT35BFA 73WT35BFA 4000.00 4300.00 4700.00 5000.00 5300.00 5700.00 6600.00 7400.00 8400.00 9700.00 10700.00 13100.00 14800.00 16600.00 6 2 3 4 73AT35DFA 73BT35DFA 73CT35DFA 73DT35DFA 73ET35DFA 73FT35DFA 73GT35DFA 73HT35DFA 73JT35DFA 73KT35DFA 73LT35DFA 73MT35DFA 73NT35DFA 73PT35DFA 73QT35DFA 73RT35DFA 73ST35DFA 73TT35DFA 73WT35DFA 4000.00 4300.00 4600.00 4900.00 5200.00 5800.00 6700.00 7500.00 8400.00 9600.00 10600.00 13100.00 14700.00 16600.00 6 2 3 4 73AT350FA 73BT350FA 73CT350FA 73DT350FA 73ET350FA 73FT350FA 73GT350FA 73HT350FA 73JT350FA 73KT350FA 73LT350FA 73MT350FA 73NT350FA 73PT350FA 73QT350FA 73RT350FA 73ST350FA 73TT350FA 73WT350FA 4000.00 4300.00 4700.00 4900.00 5300.00 5700.00 6600.00 7400.00 8400.00 9700.00 10700.00 13100.00 14700.00 16600.00 6 2 3 4 73AT35EFA 73BT35EFA 73CT35EFA 73DT35EFA 73ET35EFA 73FT35EFA 73GT35EFA 73HT35EFA 73JT35EFA 73KT35EFA 73LT35EFA 73MT35EFA 73NT35EFA 73PT35EFA 73QT35EFA 73RT35EFA 73ST35EFA 73TT35EFA 73WT35EFA 4200.00 4600.00 5000.00 5000.00 5600.00 6000.00 7000.00 7800.00 8900.00 10200.00 11300.00 13800.00 15500.00 17500.00 6 2 3 4 73AT35WFA 73BT35WFA 73CT35WFA 73DT35WFA 73ET35WFA 73FT35WFA 73GT35WFA 73HT35WFA 73JT35WFA 73KT35WFA 73LT35WFA 73MT35WFA 73NT35WFA 73PT35WFA 4400.00 4700.00 5100.00 5400.00 5700.00 6900.00 7700.00 8500.00 9500.00 10800.00 11800.00 16000.00 17600.00 19500.00 AVAILABILITY TO BE ANNOUNCED Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. 16-172 Starter selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule IEC Control Products Enclosed 3RW44 Selection Ordering Information 3RW44 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Multiple starting/stopping techniques including torque control ▪ Internal overload class 5, 10, 15, 20, or 30 ▪ Built-in graphical LCD keypad ▪ Internal self protection ▪ Fault monitoring ▪ 3 parameter sets ▪ Communication capable via opt. Profibus module ▪ Programmable inputs and outputs ▪ External keypad available 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW44 is designed for normal starting applications. 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 74 non-combination starters include: ▪ NEMA rated enclosure ▪ 3RW44 Sirius softstarter with built-in OL and bypass ▪ Circuit breaker with disconnect ▪ Control circuit transformer ▪ Reset button Ideal applications for 3RW44 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Conveying systems and lifts ▪ Hydraulics ▪ Machine tools ▪ Mills saws ▪ Crushers and grinders ▪ Mixers ▪ HVAC systems The 3RW44 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 74 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW44 For High Feature Applications Enclosed Combination with Circuit Breaker Disconnect MAX HP Class 10 Light Duty (350% * Ie for 10s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAP 4700.00 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAP 4900.00 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAP 5000.00 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAP 5500.00 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAP 5800.00 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAP 6400.00 30 30 75 — 56 3RW4434-6BC34 74GT3_BFAP 6800.00 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAP 7900.00 40 50 100 — 75 3RW4436-6BC34 74JT3_BFAP 8400.00 60 60 125 — 93 3RW4443-6BC34 74KT3_BFAP 10300.00 60 75 150 — 112 3RW4444-6BC34 74LT3_BFAP 11400.00 75 100 200 — 149 3RW4445-6BC34 74MT3_BFAP 14500.00 100 125 250 — 186 3RW4446-6BC34 74NT3_BFAP 16000.00 125 150 300 — 224 3RW4447-6BC34 74PT3_BFAP 17600.00 150 200 400 — 298 3RW4453-6BC34 73QT_BFAP 150 200 450 — 336 3RW4454-6BC34 73RT_BFAP 200 250 500 — 373 3RW4455-6BC34 73ST_BFAP 200 250 550 — 3RW4456-6BC34 73TT_BFAP 200 250 600 — 447 3RW4457-6BC34 73WT_BFAP KW List Price $ 4700.00 4900.00 5000.00 5500.00 5800.00 6400.00 6800.00 7900.00 8400.00 10300.00 11400.00 14500.00 16100.00 17700.00 NEMA 12 74AT3_0FAP 74BT3_0FAP 74CT3_0FAP 74DT3_0FAP 74ET3_0FAP 74FT3_0FAP 74GT3_0FAP 74HT3_0FAP 74JT3_0FAP 74KT3_0FAP 74LT3_0FAP 74MT3_0FAP 74NT3_0FAP 74PT3_0FAP 73QT_0FAP 73RT_0FAP 73ST_0FAP 73TT_0FAP 73WT_0FAP List Price $ 4700.00 4900.00 5000.00 5500.00 5800.00 6400.00 6800.00 7900.00 8400.00 10300.00 11400.00 14500.00 16000.00 17600.00 NEMA 4 74AT3_EFAP 74BT3_EFAP 74CT3_EFAP 74DT3_EFAP 74ET3_EFAP 74FT3_EFAP 74GT3_EFAP 74HT3_EFAP 74JT3_EFAP 74KT3_EFAP 74LT3_EFAP 74MT3_EFAP 74NT3_EFAP 74PT3_EFAP 73QT_EFAP 73RT_EFAP 73ST_EFAP 73TT_EFAP 73WT_EFAP List Price $ 5000.00 5200.00 5300.00 5800.00 6100.00 6800.00 7200.00 8300.00 8900.00 10900.00 12000.00 15300.00 16800.00 18500.00 NEMA 4/4X Stainless Steel 74AT3_WFAP 74BT3_WFAP 74CT3_WFAP 74DT3_WFAP 74ET3_WFAP 74FT3_WFAP 74GT3_WFAP 74HT3_WFAP 74JT3_WFAP List Price $ 5700.00 5900.00 6000.00 7100.00 7300.00 7700.00 8100.00 11100.00 11300.00 CONTROL PRODUCTS NEMA 3R 74AT3_DFAP 74BT3_DFAP 74CT3_DFAP 74DT3_DFAP 74ET3_DFAP 74FT3_DFAP 74GT3_DFAP 74HT3_DFAP 74JT3_DFAP 74KT3_DFAP 74LT3_DFAP 74MT3_DFAP 74NT3_DFAP 74PT3_DFAP 73QT_DFAP 73RT_DFAP 73ST_DFAP 73TT_DFAP 73WT_DFAP 16 Rated Operating Current 26 32 42 51 68 82 100 117 145 180 215 280 315 385 494 551 615 693 780 AVAILABILITY TO BE ANNOUNCED — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 15 20 25 30 50 60 75 75 100 125 150 200 250 300 400 450 500 550 600 20 25 30 40 50 75 75 100 125 150 200 250 300 400 500 600 700 750 850 — — — — — — — — — — — — — — — — — — — 6 2 3 4 74AT35BFAP 5000.00 74BT35BFAP 5200.00 74CT35BFAP 5400.00 74DT35BFAP 5900.00 74ET35BFAP 6300.00 74FT35BFAP 6900.00 74GT35BFAP 7400.00 74HT35BFAP 8500.00 74JT35BFAP 9100.00 74KT35BFAP 11200.00 74LT35BFAP 12500.00 74MT35BFAP 15800.00 74NT35BFAP 17400.00 74PT35BFAP 19300.00 73QT35BFAPP 73RT35BFAPP 73ST35BFAPP 73TT35BFAPP 73WT35BFAPP 6 2 3 4 74AT35DFAP 74BT35DFAP 74CT35DFAP 74DT35DFAP 74ET35DFAP 74FT35DFAP 74GT35DFAP 74HT35DFAP 74JT35DFAP 74KT35DFAP 74LT35DFAP 74MT35DFAP 74NT35DFAP 74PT35DFAP 73QT35DFAP 73RT35DFAP 73ST35DFAP 73TT35DFAP 73WT35DFAP 5000.00 5200.00 5300.00 5900.00 6200.00 6900.00 7400.00 8500.00 9200.00 11200.00 12500.00 15800.00 17500.00 19400.00 6 2 3 4 74AT350FAP 74BT350FAP 74CT350FAP 74DT350FAP 74ET350FAP 74FT350FAP 74GT350FAP 74HT350FAP 74JT350FAP 74KT350FAP 74LT350FAP 74MT350FAP 74NT350FAP 74PT350FAP 73QT350FAP 73RT350FAP 73ST350FAP 73TT350FAP 73WT350FAP 5000.00 5200.00 5300.00 5900.00 6200.00 6900.00 7300.00 8500.00 9200.00 11200.00 12500.00 15800.00 17400.00 19300.00 6 2 3 4 74AT35EFAP 74BT35EFAP 74CT35EFAP 74DT35EFAP 74ET35EFAP 74FT35EFAP 74GT35EFAP 74HT35EFAP 74JT35EFAP 74KT35EFAP 74LT35EFAP 74MT35EFAP 74NT35EFAP 74PT35EFAP 73QT35EFAP 73RT35EFAP 73ST35EFAP 73TT35EFAP 73WT35EFAP 5300.00 5600.00 5700.00 6200.00 6600.00 7300.00 7800.00 9000.00 9400.00 11800.00 13200.00 16600.00 18400.00 20300.00 6 2 3 4 74AT35WFAP 6000.00 74BT35WFAP 6200.00 74CT35WFAP 6300.00 74DT35WFAP 7500.00 74ET35WFAP 7800.00 74FT35WFAP 8100.00 74GT35WFAP 8600.00 74HT35WFAP 11800.00 74JT35WFAP 12100.00 AVAILABILITY TO BE ANNOUNCED Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. Discount Schedule IEC Starter selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-173 Soft Starter Control 26 32 42 51 68 82 100 117 145 180 215 280 315 385 494 551 615 693 780 200V 230V 380V 460V 3RW4422-1BC35 3RW4423-1BC35 3RW4424-1BC35 3RW4425-1BC35 3RW4426-1BC35 3RW4427-1BC35 3RW4434-6BC35 3RW4435-6BC35 3RW4436-6BC35 3RW4443-6BC35 3RW4444-6BC35 3RW4445-6BC35 3RW4446-6BC35 3RW4447-6BC35 3RW4453-6BC35 3RW4454-6BC35 3RW4455-6BC35 3RW4456-6BC35 3RW4457-6BC35 Control Products Enclosed 3RW44 Selection Ordering Information 3RW44 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Multiple starting/stopping techniques including torque control ▪ Internal overload class 5, 10, 15, 20, or 30 ▪ Built-in graphical LCD keypad ▪ Internal self protection ▪ Fault monitoring ▪ 3 parameter sets ▪ Communication capable via opt. Profibus module ▪ Programmable inputs and outputs ▪ External keypad available 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW44 is designed for normal starting applications. 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 74 non-combination starters include: ▪ NEMA rated enclosure ▪ 3RW44 Sirius softstarter with built-in OL and bypass ▪ Circuit breaker with disconnect ▪ Control circuit transformer ▪ Reset button Ideal applications for 3RW44 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Conveying systems and lifts ▪ Hydraulics ▪ Machine tools ▪ Mills saws ▪ Crushers and grinders ▪ Mixers ▪ HVAC systems The 3RW44 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 74 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW44 For High Feature Applications CONTROL PRODUCTS 16 Enclosed Combination with Circuit Breaker Disconnect Rated Operating Current 26 32 42 51 68 82 97 113 134 175 195 243 263 326 494 551 615 634 650 MAX HP Class 20 Severe Duty (350% * Ie for 20s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAP 4700.00 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAP 4900.00 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAP 5000.00 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAP 5500.00 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAP 5800.00 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAP 6400.00 30 30 60 — 45 3RW4434-6BC34 74GT3_BFAP 6800.00 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAP 7900.00 40 50 75 — 56 3RW4436-6BC34 74JT3_BFAP 8400.00 50 60 100 — 75 3RW4443-6BC34 74KT3_BFAP 10300.00 60 75 125 — 93 3RW4444-6BC34 74LT3_BFAP 11400.00 75 75 150 — 112 3RW4445-6BC34 74MT3_BFAP 14500.00 75 100 200 — 149 3RW4446-6BC34 74NT3_BFAP 16000.00 100 125 250 — 186 3RW4447-6BC34 74PT3_BFAP 17600.00 150 150 400 — 298 3RW4453-6BC34 73QT_BFAP 150 200 450 — 336 3RW4454-6BC34 73RT_BFAP 200 200 500 — 373 3RW4455-6BC34 73ST_BFAP 200 250 500 — 373 3RW4456-6BC34 73TT_BFAP 200 250 550 — 373 3RW4457-6BC34 73WT_BFAP KW NEMA 3R 74AT3_DFAP 74BT3_DFAP 74CT3_DFAP 74DT3_DFAP 74ET3_DFAP 74FT3_DFAP 74GT3_DFAP 74HT3_DFAP 74JT3_DFAP 74KT3_DFAP 74LT3_DFAP 74MT3_DFAP 74NT3_DFAP 74PT3_DFAP 73QT_DFAP 73RT_DFAP 73ST_DFAP 73TT_DFAP 73WT_DFAP List Price $ 4700.00 4900.00 5000.00 5500.00 5800.00 6400.00 6800.00 7900.00 8400.00 10300.00 11400.00 14500.00 16100.00 17700.00 NEMA 12 74AT3_0FAP 74BT3_0FAP 74CT3_0FAP 74DT3_0FAP 74ET3_0FAP 74FT3_0FAP 74GT3_0FAP 74HT3_0FAP 74JT3_0FAP 74KT3_0FAP 74LT3_0FAP 74MT3_0FAP 74NT3_0FAP 74PT3_0FAP 73QT_0FAP 73RT_0FAP 73ST_0FAP 73TT_0FAP 73WT_0FAP List Price $ 4700.00 4900.00 5000.00 5500.00 5800.00 6400.00 6800.00 7900.00 8400.00 10300.00 11400.00 14500.00 16000.00 17600.00 NEMA 4 74AT3_EFAP 74BT3_EFAP 74CT3_EFAP 74DT3_EFAP 74ET3_EFAP 74FT3_EFAP 74GT3_EFAP 74HT3_EFAP 74JT3_EFAP 74KT3_EFAP 74LT3_EFAP 74MT3_EFAP 74NT3_EFAP 74PT3_EFAP 73QT_EFAP 73RT_EFAP 73ST_EFAP 73TT_EFAP 73WT_EFAP List Price $ 5000.00 5200.00 5300.00 5800.00 6100.00 6800.00 7200.00 8300.00 8900.00 10900.00 12000.00 15300.00 16800.00 18500.00 NEMA 4/4X Stainless Steel 74AT3_WFAP 74BT3_WFAP 74CT3_WFAP 74DT3_WFAP 74ET3_WFAP 74FT3_WFAP 74GT3_WFAP 74HT3_WFAP 74JT3_WFAP List Price $ 5700.00 5900.00 6000.00 7100.00 7300.00 7700.00 8100.00 11100.00 11300.00 Soft Starter Control AVAILABILITY TO BE ANNOUNCED 26 32 42 51 68 82 97 113 134 175 195 243 263 326 494 551 615 693 780 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 15 20 25 30 50 60 60 75 75 100 125 150 200 250 400 450 500 550 600 20 25 30 40 50 75 75 100 125 150 200 200 250 300 500 550 600 650 700 — — — — — — — — — — — — — — — — — — — 200V 230V 380V 460V 3RW4422-1BC35 3RW4423-1BC35 3RW4424-1BC35 3RW4425-1BC35 3RW4426-1BC35 3RW4427-1BC35 3RW4434-6BC35 3RW4435-6BC35 3RW4436-6BC35 3RW4443-6BC35 3RW4444-6BC35 3RW4445-6BC35 3RW4446-6BC35 3RW4447-6BC35 3RW4453-6BC35 3RW4454-6BC35 3RW4455-6BC35 3RW4456-6BC35 3RW4457-6BC35 6 2 3 4 74AT35BFAP 74BT35BFAP 74CT35BFAP 74DT35BFAP 74ET35BFAP 74FT35BFAP 74GT35BFAP 74HT35BFAP 74JT35BFAP 74KT35BFAP 74LT35BFAP 74MT35BFAP 74NT35BFAP 74PT35BFAP 73QT35BFAP 73RT35BFAP 73ST35BFAP 73TT35BFAP 73WT35BFAP 5000.00 5200.00 5400.00 5900.00 6300.00 6900.00 7400.00 8500.00 9100.00 11200.00 12500.00 15800.00 17400.00 19300.00 6 2 3 4 74AT35DFAP 74BT35DFAP 74CT35DFAP 74DT35DFAP 74ET35DFAP 74FT35DFAP 74GT35DFAP 74HT35DFAP 74JT35DFAP 74KT35DFAP 74LT35DFAP 74MT35DFAP 74NT35DFAP 74PT35DFAP 73QT35DFAP 73RT35DFAP 73ST35DFAP 73TT35DFAP 73WT35DFAP 5000.00 5200.00 5300.00 5900.00 6200.00 6900.00 7400.00 8500.00 9200.00 11200.00 12500.00 15800.00 17500.00 19400.00 6 2 3 4 74AT350FAP 74BT350FAP 74CT350FAP 74DT350FAP 74ET350FAP 74FT350FAP 74GT350FAP 74HT350FAP 74JT350FAP 74KT350FAP 74LT350FAP 74MT350FAP 74NT350FAP 74PT350FAP 73QT350FAP 73RT350FAP 73ST350FAP 73TT350FAP 73WT350FAP 5000.00 5200.00 5300.00 5900.00 6200.00 6900.00 7300.00 8500.00 9200.00 11200.00 12500.00 15800.00 17400.00 19300.00 6 2 3 4 74AT35EFAP 74BT35EFAP 74CT35EFAP 74DT35EFAP 74ET35EFAP 74FT35EFAP 74GT35EFAP 74HT35EFAP 74JT35EFAP 74KT35EFAP 74LT35EFAP 74MT35EFAP 74NT35EFAP 74PT35EFAP 73QT35EFAP 73RT35EFAP 73ST35EFAP 73TT35EFAP 73WT35EFAP 5300.00 5600.00 5700.00 6200.00 6600.00 7300.00 7800.00 9000.00 9400.00 11800.00 13200.00 16600.00 18400.00 20300.00 6 2 3 4 74AT35WFAP 6000.00 74BT35WFAP 6200.00 74CT35WFAP 6300.00 74DT35WFAP 7500.00 74ET35WFAP 7800.00 74FT35WFAP 8100.00 74GT35WFAP 8600.00 74HT35WFAP 11800.00 74JT35WFAP 12100.00 AVAILABILITY TO BE ANNOUNCED Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. 16-174 Starter selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule IEC Control Products Enclosed 3RW44 Selection Ordering Information 3RW44 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Multiple starting/stopping techniques including torque control ▪ Internal overload class 5, 10, 15, 20, or 30 ▪ Built-in graphical LCD keypad ▪ Internal self protection ▪ Fault monitoring ▪ 3 parameter sets ▪ Communication capable via opt. Profibus module ▪ Programmable inputs and outputs ▪ External keypad available 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW44 is designed for normal starting applications. 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 74 non-combination starters include: ▪ NEMA rated enclosure ▪ 3RW44 Sirius softstarter with built-in OL and bypass ▪ Fusible disconnect ▪ Control circuit transformer ▪ Reset button Ideal applications for 3RW44 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Conveying systems and lifts ▪ Hydraulics ▪ Machine tools ▪ Mills saws ▪ Crushers and grinders ▪ Mixers ▪ HVAC systems The 3RW44 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 74 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW44 For High Feature Applications Enclosed Combination with Fusible Disconnect MAX HP Class 10 Light Duty OPEN Style 200V 230V 460V 575V 380V (Starter Only) NEMA 1 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAF 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAF 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAF 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAF 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAF 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAF 30 30 75 — 56 3RW4434-6BC34 74GT3_BFAF 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAF 40 50 100 — 75 3RW4436-6BC34 74JT3_BFAF 60 60 125 — 93 3RW4443-6BC34 74KT3_BFAF 60 75 150 — 112 3RW4444-6BC34 74LT3_BFAF 75 100 200 — 149 3RW4445-6BC34 74MT3_BFAF 100 125 250 — 186 3RW4446-6BC34 74NT3_BFAF 125 150 300 — 224 3RW4447-6BC34 74PT3_BFAF 150 200 400 — 298 3RW4453-6BC34 73QT_BFAF 150 200 450 — 336 3RW4454-6BC34 73RT_BFAF 200 250 500 — 373 3RW4455-6BC34 73ST_BFAF 200 250 550 — 3RW4456-6BC34 73TT_BFAF 200 250 600 — 447 3RW4457-6BC34 73WT_BFAF KW NEMA 3R 74AT3_DFAF 74BT3_DFAF 74CT3_DFAF 74DT3_DFAF 74ET3_DFAF 74FT3_DFAF 74GT3_DFAF 74HT3_DFAF 74JT3_DFAF 74KT3_DFAF 74LT3_DFAF 74MT3_DFAF 74NT3_DFAF 74PT3_DFAF 73QT_DFAF 73RT_DFAF 73ST_DFAF 73TT_DFAF 73WT_DFAF List Price $ 4500.00 4800.00 5100.00 5400.00 5700.00 6400.00 6800.00 7600.00 8800.00 11000.00 11900.00 14900.00 16400.00 18100.00 NEMA 12 74AT3_0FAF 74BT3_0FAF 74CT3_0FAF 74DT3_0FAF 74ET3_0FAF 74FT3_0FAF 74GT3_0FAF 74HT3_0FAF 74JT3_0FAF 74KT3_0FAF 74LT3_0FAF 74MT3_0FAF 74NT3_0FAF 74PT3_0FAF 73QT_0FAF 73RT_0FAF 73ST_0FAF 73TT_0FAF 73WT_0FAF List Price $ 4500.00 4800.00 5100.00 5400.00 5700.00 6400.00 6800.00 7600.00 8800.00 11000.00 11900.00 14900.00 16400.00 18000.00 NEMA 4 74AT3_EFAF 74BT3_EFAF 74CT3_EFAF 74DT3_EFAF 74ET3_EFAF 74FT3_EFAF 74GT3_EFAF 74HT3_EFAF 74JT3_EFAF 74KT3_EFAF 74LT3_EFAF 74MT3_EFAF 74NT3_EFAF 74PT3_EFAF 73QT_EFAF 73RT_EFAF 73ST_EFAF 73TT_EFAF 73WT_EFAF List Price $ 4800.00 5100.00 5400.00 5700.00 6000.00 6800.00 7200.00 8000.00 9300.00 11600.00 12400.00 15700.00 17300.00 18900.00 NEMA 4/4X Stainless Steel 74AT3_WFAF 74BT3_WFAF 74CT3_WFAF 74DT3_WFAF 74ET3_WFAF 74FT3_WFAF 74GT3_WFAF 74HT3_WFAF 74JT3_WFAF List Price $ 5500.00 5800.00 6100.00 7000.00 7300.00 7700.00 8100.00 10800.00 11700.00 CONTROL PRODUCTS List Price $ 4600.00 4800.00 5100.00 5500.00 5700.00 6400.00 6800.00 7600.00 8800.00 11000.00 11900.00 14900.00 16400.00 18000.00 16 Rated Operating Current 26 32 42 51 68 82 100 117 145 180 215 280 315 385 494 551 615 693 780 AVAILABILITY TO BE ANNOUNCED — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 15 20 25 30 50 60 75 75 100 125 150 200 250 300 400 450 500 550 600 20 25 30 40 50 75 75 100 125 150 200 250 300 400 500 600 700 750 850 — — — — — — — — — — — — — — — — — — — 6 2 3 4 74AT35BFAF 74BT35BFAF 74CT35BFAF 74DT35BFAF 74ET35BFAF 74FT35BFAF 74GT35BFAF 74HT35BFAF 74JT35BFAF 74KT35BFAF 74LT35BFAF 74MT35BFAF 74NT35BFAF 74PT35BFAF 73QT35BFAF 73RT35BFAF 73ST35BFAF 73TT35BFAF 73WT35BFAF 4800.00 5100.00 5500.00 5800.00 6200.00 6900.00 7400.00 8200.00 9600.00 11900.00 12900.00 16100.00 17800.00 19700.00 6 2 3 4 74AT35DFAF 74BT35DFAF 74CT35DFAF 74DT35DFAF 74ET35DFAF 74FT35DFAF 74GT35DFAF 74HT35DFAF 74JT35DFAF 74KT35DFAF 74LT35DFAF 74MT35DFAF 74NT35DFAF 74PT35DFAF 73QT35DFAF 73RT35DFAF 73ST35DFAF 73TT35DFAF 73WT35DFAF 4800.00 5100.00 5500.00 5800.00 6100.00 6900.00 7400.00 8200.00 9600.00 11900.00 12900.00 16100.00 17900.00 19800.00 6 2 3 4 74AT350FAF 74BT350FAF 74CT350FAF 74DT350FAF 74ET350FAF 74FT350FAF 74GT350FAF 74HT350FAF 74JT350FAF 74KT350FAF 74LT350FAF 74MT350FAF 74NT350FAF 74PT350FAF 73QT350FAF 73RT350FAF 73ST350FAF 73TT350FAF 73WT350FAF 4800.00 5100.00 5500.00 5800.00 6100.00 6900.00 7400.00 8200.00 9600.00 11900.00 12900.00 16100.00 17800.00 19700.00 6 2 3 4 74AT35EFAF 74BT35EFAF 74CT35EFAF 74DT35EFAF 74ET35EFAF 74FT35EFAF 74GT35EFAF 74HT35EFAF 74JT35EFAF 74KT35EFAF 74LT35EFAF 74MT35EFAF 74NT35EFAF 74PT35EFAF 73QT35EFAF 73RT35EFAF 73ST35EFAF 73TT35EFAF 73WT35EFAF 5100.00 5400.00 5800.00 6100.00 6500.00 7300.00 7800.00 8800.00 10100.00 12500.00 13600.00 17000.00 18700.00 20700.00 6 2 3 4 74AT35WFAF 5800.00 74BT35WFAF 6100.00 74CT35WFAF 6500.00 74DT35WFAF 7400.00 74ET35WFAF 7700.00 74FT35WFAF 8200.00 74GT35WFAF 8700.00 74HT35WFAF 11500.00 74JT35WFAF 12500.00 AVAILABILITY TO BE ANNOUNCED Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. Discount Schedule IEC Starter selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-175 Soft Starter Control 26 32 42 51 68 82 100 117 145 180 215 280 315 385 494 551 615 693 780 200V 230V 380V 460V 3RW4422-1BC35 3RW4423-1BC35 3RW4424-1BC35 3RW4425-1BC35 3RW4426-1BC35 3RW4427-1BC35 3RW4434-6BC35 3RW4435-6BC35 3RW4436-6BC35 3RW4443-6BC35 3RW4444-6BC35 3RW4445-6BC35 3RW4446-6BC35 3RW4447-6BC35 3RW4453-6BC35 3RW4454-6BC35 3RW4455-6BC35 3RW4456-6BC35 3RW4457-6BC35 Control Products Enclosed 3RW44 Selection Ordering Information 3RW44 Enclosed features: ▪ Available in NEMA 1, 12, 3R, 4, and 4 stainless steel ▪ Compact size ▪ Built-in bypass contactor ▪ Multiple starting/stopping techniques including torque control ▪ Internal overload class 5, 10, 15, 20, or 30 ▪ Built-in graphical LCD keypad ▪ Internal self protection ▪ Fault monitoring ▪ 3 parameter sets ▪ Communication capable via opt. Profibus module ▪ Programmable inputs and outputs ▪ External keypad available 䊳 Enclosed devices should be ordered by the FLA of the motor. 䊳 The 3RW44 is designed for normal starting applications. 䊳 For factory modifications see page 16-177. 䊳 For complete derating and application info see the 2006 Industrial Controls catalog CPPC-06000-0106. 䊳 For dimensional drawings see page 16-178. Class 74 non-combination starters include: ▪ NEMA rated enclosure ▪ 3RW44 Sirius softstarter with built-in OL and bypass ▪ Fusible disconnect ▪ Control circuit transformer ▪ Reset button Ideal applications for 3RW44 enclosed softstarters: ▪ Fans ▪ Pumps ▪ Conveying systems and lifts ▪ Hydraulics ▪ Machine tools ▪ Mills saws ▪ Crushers and grinders ▪ Mixers ▪ HVAC systems The 3RW44 severe duty rating table should be applied for high inertia applications such rock crushers, chippers, screw compressors, ect. Class 74 starters are built to UL and CSA standards. For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center. 3RW44 For High Feature Applications CONTROL PRODUCTS 16 Enclosed Combination with Fusible Disconnect Rated Operating Current 26 32 42 51 68 82 97 113 134 175 195 243 263 326 494 551 615 634 650 MAX HP Class 20 Severe Duty (350% * Ie for 20s) OPEN Style List 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAF 4600.00 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAF 4800.00 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAF 5100.00 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAF 5500.00 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAF 5700.00 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAF 6400.00 30 30 60 — 45 3RW4434-6BC34 74GT3_BFAF 6800.00 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAF 7600.00 40 50 75 — 56 3RW4436-6BC34 74JT3_BFAF 8800.00 50 60 100 — 75 3RW4443-6BC34 74KT3_BFAF 11000.00 60 75 125 — 93 3RW4444-6BC34 74LT3_BFAF 11900.00 75 75 150 — 112 3RW4445-6BC34 74MT3_BFAF 14900.00 75 100 200 — 149 3RW4446-6BC34 74NT3_BFAF 16400.00 100 125 250 — 186 3RW4447-6BC34 74PT3_BFAF 18000.00 150 150 400 — 298 3RW4453-6BC34 73QT_BFAF 150 200 450 — 336 3RW4454-6BC34 73RT_BFAF 200 200 500 — 373 3RW4455-6BC34 73ST_BFAF 200 250 500 — 373 3RW4456-6BC34 73TT_BFAF 200 250 550 — 373 3RW4457-6BC34 73WT_BFAF KW NEMA 3R 74AT3_DFAF 74BT3_DFAF 74CT3_DFAF 74DT3_DFAF 74ET3_DFAF 74FT3_DFAF 74GT3_DFAF 74HT3_DFAF 74JT3_DFAF 74KT3_DFAF 74LT3_DFAF 74MT3_DFAF 74NT3_DFAF 74PT3_DFAF 73QT_DFAF 73RT_DFAF 73ST_DFAF 73TT_DFAF 73WT_DFAF List Price $ 4500.00 4800.00 5100.00 5400.00 5700.00 6400.00 6800.00 7600.00 8800.00 11000.00 11900.00 14900.00 16400.00 18100.00 NEMA 12 74AT3_0FAF 74BT3_0FAF 74CT3_0FAF 74DT3_0FAF 74ET3_0FAF 74FT3_0FAF 74GT3_0FAF 74HT3_0FAF 74JT3_0FAF 74KT3_0FAF 74LT3_0FAF 74MT3_0FAF 74NT3_0FAF 74PT3_0FAF 73QT_0FAF 73RT_0FAF 73ST_0FAF 73TT_0FAF 73WT_0FAF List Price $ 4500.00 4800.00 5100.00 5400.00 5700.00 6400.00 6800.00 7600.00 8800.00 11000.00 11900.00 14900.00 16400.00 18000.00 NEMA 4 74AT3_EFAF 74BT3_EFAF 74CT3_EFAF 74DT3_EFAF 74ET3_EFAF 74FT3_EFAF 74GT3_EFAF 74HT3_EFAF 74JT3_EFAF 74KT3_EFAF 74LT3_EFAF 74MT3_EFAF 74NT3_EFAF 74PT3_EFAF 73QT_EFAF 73RT_EFAF 73ST_EFAF 73TT_EFAF 73WT_EFAF List Price $ 4800.00 5100.00 5400.00 5700.00 6000.00 6800.00 7200.00 8000.00 9300.00 11600.00 12400.00 15700.00 17300.00 18900.00 NEMA 4/4X Stainless Steel 74AT3_WFAF 74BT3_WFAF 74CT3_WFAF 74DT3_WFAF 74ET3_WFAF 74FT3_WFAF 74GT3_WFAF 74HT3_WFAF 74JT3_WFAF List Price $ 5500.00 5800.00 6100.00 7000.00 7300.00 7700.00 8100.00 10800.00 11700.00 Soft Starter Control AVAILABILITY TO BE ANNOUNCED 26 32 42 51 68 82 97 113 134 175 195 243 263 326 494 551 615 693 780 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 15 20 25 30 50 60 60 75 75 100 125 150 200 250 400 450 500 550 600 20 25 30 40 50 75 75 100 125 150 200 200 250 300 500 550 600 650 700 — — — — — — — — — — — — — — — — — — — 200V 230V 380V 460V 3RW4422-1BC35 3RW4423-1BC35 3RW4424-1BC35 3RW4425-1BC35 3RW4426-1BC35 3RW4427-1BC35 3RW4434-6BC35 3RW4435-6BC35 3RW4436-6BC35 3RW4443-6BC35 3RW4444-6BC35 3RW4445-6BC35 3RW4446-6BC35 3RW4447-6BC35 3RW4453-6BC35 3RW4454-6BC35 3RW4455-6BC35 3RW4456-6BC35 3RW4457-6BC35 6 2 3 4 74AT35BFAF 74BT35BFAF 74CT35BFAF 74DT35BFAF 74ET35BFAF 74FT35BFAF 74GT35BFAF 74HT35BFAF 74JT35BFAF 74KT35BFAF 74LT35BFAF 74MT35BFAF 74NT35BFAF 74PT35BFAF 73QT35BFAF 73RT35BFAF 73ST35BFAF 73TT35BFAF 73WT35BFAF 4800.00 5100.00 5500.00 5800.00 6200.00 6900.00 7400.00 8200.00 9600.00 11900.00 12900.00 16100.00 17800.00 19700.00 6 2 3 4 74AT35DFAF 74BT35DFAF 74CT35DFAF 74DT35DFAF 74ET35DFAF 74FT35DFAF 74GT35DFAF 74HT35DFAF 74JT35DFAF 74KT35DFAF 74LT35DFAF 74MT35DFAF 74NT35DFAF 74PT35DFAF 73QT35DFAF 73RT35DFAF 73ST35DFAF 73TT35DFAF 73WT35DFAF 4800.00 5100.00 5500.00 5800.00 6100.00 6900.00 7400.00 8200.00 9600.00 11900.00 12900.00 16100.00 17900.00 19800.00 6 2 3 4 74AT350FAF 74BT350FAF 74CT350FAF 74DT350FAF 74ET350FAF 74FT350FAF 74GT350FAF 74HT350FAF 74JT350FAF 74KT350FAF 74LT350FAF 74MT350FAF 74NT350FAF 74PT350FAF 73QT350FAF 73RT350FAF 73ST350FAF 73TT350FAF 73WT350FAF 4800.00 5100.00 5500.00 5800.00 6100.00 6900.00 7400.00 8200.00 9600.00 11900.00 12900.00 16100.00 17800.00 19700.00 6 2 3 4 74AT35EFAF 74BT35EFAF 74CT35EFAF 74DT35EFAF 74ET35EFAF 74FT35EFAF 74GT35EFAF 74HT35EFAF 74JT35EFAF 74KT35EFAF 74LT35EFAF 74MT35EFAF 74NT35EFAF 74PT35EFAF 73QT35EFAF 73RT35EFAF 73ST35EFAF 73TT35EFAF 73WT35EFAF 5100.00 5400.00 5800.00 6100.00 6500.00 7300.00 7800.00 8800.00 10100.00 12500.00 13600.00 17000.00 18700.00 20700.00 6 2 3 4 74AT35WFAF 5800.00 74BT35WFAF 6100.00 74CT35WFAF 6500.00 74DT35WFAF 7400.00 74ET35WFAF 7700.00 74FT35WFAF 8200.00 74GT35WFAF 8700.00 74HT35WFAF 11500.00 74JT35WFAF 12500.00 AVAILABILITY TO BE ANNOUNCED Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. HPs are for reference only. Enclosed ratings are at 40°C. 16-176 Starter selection is dependent on type of application. Ie = FLA rating of motor. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule IEC Control Products Factory Modifications Selection Available modifications in STANDARD enclosure Pilot Devices Push Buttons Start/Stop Selector Switches Hand-Off-Auto Hand-Off-Auto (keyed) Off-On Pilot Light Red ‘On’ Green ‘On’ Red ‘Run’ Green ‘Run’ Red ‘Off’ Green ‘Off’ Amber ‘Fault’ White ‘Control Power On’ Red ‘On’ Push-to-Test Green ‘On’ Push-to-Test Green ‘Off’ Push-to-Test Custom pilot light (state color and nameplate text) Through the Door Metering External keypad for 3RW44 Elapse time meter Control Options Profibus Communication Module (installed-connection cable not supplied Ground Lug - 1 Conductor Alarm Package - Includes horn, light, relay & push button Electronic 8 function timing relay (.05s - 100h) supplied mounted and unwired 3RW40/44 73/74 ALL A1 260. 3RW40/44 3RW40/44 3RW40/44 73/74 73/74 73/74 ALL ALL ALL A3 S3 A4 260. 390. 260. 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 73/74 73/74 73/74 73/74 73/74 73/74 73/74 73/74 73/74 73/74 73/74 73/74 ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL ALL FA FB FC FD FJ FK FL FW FS FT FU FZ 250. 250. 250. 250. 250. 250. 250. 250. 360. 360. 360. 300. 3RW44 3RW40/44 73/74 N1, N12 N1, N12 (120V) K1 M5 1100. 300. 3RW44 73/74 ALL P1 1000. 3RW40/44 3RW40/44 73/74 73/74 ALL N1, N3, N12 L10 M7 100. 500. 3RW40/44 73/74 ALL TR 400. R04 R22 R40 L6 N3 N1 TC3 TC6 TC9 TC12 300. 300. 300. 500. 100. 100. 150. 150. 150. 150. Control Relay supplied mounted and unwired (4-pole max) 3RW40/44 73/74 ALL Circuit Breaker Shunt Trip (included std in 3RW40 versions) Service Entrance Labeled Function identification plate, with marking as specified Terminal Block 3 point Terminal Block 6 point Terminal Block 9 point Terminal Block 12 point 74 74 73/74 73/74 73/74 73/74 73/74 ALL ALL ALL ALL ALL ALL ALL 3RW44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 3RW40/44 CONTROL PRODUCTS Enclosed Style Mod Suffix List Price Adder $ 16 3RW Version Enclosure NEMA Type Modification Options Requiring the Modified Options Box Size Modification MODIFIED BOX ADDER (change 8th character to a ‘G’) 3RW Version 3RW40 3RW44 Enclosed Enclosed Mod Style NEMA Type Suffix List Price Adder $ 117 – 285 315 A–D E N1/12/3R/4 800. 800. 73 N4SS 2600. 2600. N1/12/3R/4 800. 0 74 N4SS — 2600. 26 – 51 68 A–D E N1/12/3R/4 300. 1000. 73 N4SS 900. 3400. N1/12/3R/4 1100. 1000. 74 N4SS 3000. 2600. 385 F 0 500. 0 — 82 – 117 F–H 1000. 2600. 800. 2500. 145 – 215 280 – 385 J–L M–P 1000. 0 2500. 0 500. 0 — 600. 117 A 145 – 205 248 B, C D 315 – 385 E, F Mod Box Options 3RW40 current size (3rd character) (3rd character) Contactor Options Isolation contactor 3RW40/44 Emergency HP Rated Bypass Starter 3RW40 *Includes keyed selector switch to select 3RW44 between soft start and across the line start Extra Capacity CPT 100 VA Extra Control Options Space Heater (120V separate control) Space Heater with Thermostat (120V separate control) Lightning Arrestor Limited to N4SS offering. Discount Schedule IEC 3RW40/44 26 – 42 A, B, C 51 – 68 D, E 82 – 117 F, G, H 145 – 215 280 J, K, L M 315 – 385 N, P 73/74 73/74 N1/12/3R/4 N1/12/3R/4 IC A12 700. 1200. 1700. 3500. 1800. 5000. 2600. 6600. 4300. 10000. 73/74 N1/12/3R/4 A12 1300. 1600. 1900. 3200. 4100. 5800. 73/74 ALL CA 600. 600. 600. 600. 600. 600. 3RW40/44 73/74 ALL SH 300. 3RW40/44 73/74 ALL ST 500. 3RW40/44 73/74 ALL L 600. An isolation contactor is included for 3RW40. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-177 Soft Starter Control 3RW44 current size Control Products Class 73, 74 Dimensions Dimensions are in inches and are for reference only (not for construction). Certain styles may deviate from values indicated. Non-Combination Class 73 Combination Type Class 74 N1, N12, N4 Standard Enclosure CONTROL PRODUCTS 16 3RW40 3RW44 Amps 117-145 205-315 385 26-68 82-117 145-215 280-385 A 36 36 54 26 36 36 54 N1, N12, N4 Standard Enclosure B 18 22 36 12.5 18 22 36 C 15 20 20 15 15 20 20 3RW44 N4 Stainless Steel Standard Enclosure 3RW40 3RW44 Amps 117 145-205 248-385 26-51 68-82 100-117 145-385 A 36 36 54 26 36 36 54 B 18 22 36 12.5 18 22 36 C 15 20 20 15 15 20 20 B 36 22 36 C 20 20 20 N1, N12, N4 Modified Enclosure 3RW40 3RW44 Soft Starter Control 3RW40 Amps 117-385 26-51 68-385 A 56 36 54 N4 Stainless Steel Modified Enclosure 3RW40 3RW44 Amps 117-385 26-51 68-385 A 54 36 54 B 36 22 36 C 20 20 20 A 50 66 90 90 36 50 66 90 90 B 25 25 30 40 23 25 25 30 40 C 20 20 20 20 15 20 20 20 20 N4 Stainless Steel Standard Enclosure 3RW40 3RW44 Amps 117-145 205-300 26-42 51-100 117-145 180-385 A 54 90 36 50 54 90 B 36 40 23 25 36 40 C 20 20 15 20 20 20 B 30 30 40 30 30 40 C 20 20 20 20 20 20 N1, N12, N4 Modified Enclosure 3RW40 3RW44 Amps 117-248 315 385 26-215 280 315-385 A 76 90 90 76 90 90 N4 Stainless Steel Modified Enclosure 3RW40 3RW44 16-178 Amps 117-145 145-205 248-315 385 26-68 82-117 145-215 280 315-384 Amps 117-145 26-145 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog A 76 76 B 30 30 C 20 20 Control Products Class 73, 74 Wiring Diagrams 16 CONTROL PRODUCTS Soft Starter Control Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-179 Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations Features • Snap In Legend Inserts • Flush and Surface Mounted Types • Convertible Selector • Double Break Contacts • Dual Voltage Pilot Light with Snap In Lens • Conversion Kits • UL Listed File #E22655 • CSA Certified File #LR6535 Application Standard duty control stations are used with magnetic controllers to control the starting, stopping, reversing or speed of applicable motors. Padlock Attachment Kit 50ZAL can be mounted to any Type 1 surface mounted station by the lower screw which fastens the cover to the station base. Made of heavy steel, chrome plated, the attachment provides for the padlocking of a push button in the depressed position or a selector switch in any position. When used with a push button operator, raised Legend Insert D53493003 (Red Stop) must be used. Pendant Bracket Adapts standard Type 1 surface mounted stations for suspension from a cable or chain. Bracket 50ZAP2 is used for one and two unit stations, 50ZAP3 for three unit stations. General Electrical Ratings NEMA AC Ratings 50/60Hz Nema B600 5 Continuous Amps Volts 120 240 480 600 VA Make 30 15 7.5 6 3600 Break 3 1.5 0.75 0.6 360 Ordering Information • Legend Inserts see page 16-187. • Accessories see page 16-187. Stations are assembled of one, two or three push button, selector switch or pilot light units in a variety of combinations to provide compact control units for remote control of magnetic starters and contactors. CONTROL PRODUCTS 16 Station enclosures are available in Type 1 surface mounted, 1B flush plate mounted and 4 watertight. Features Type 1 surface mounted bases are constructed of 14 gauge sheet steel, primed and finished in baked gray enamel. The base is predrilled to receive a variety of contact blocks, pilot lights and accessory devices. Covers are of 20 gauge sheet steel, wrap- around construction, primed and finished in baked gray enamel. Furnas Type 4 watertight heavy duty push button stations are supplied with a provision to padlock the stop button in the depressed position. Enclosures are predrilled and tapped for 3/4" conduit. Contact blocks have double break, fine silver contacts with a NEMA B600 rating. Type 4 stations have a NEMA A600 rating. The pilot light assembly is dual voltage with clearly marked pressure type terminals for 120 volt or 240 volt connection. The lens of the pilot light snaps into the cover and is available in both red and green. Push buttons are equipped with an operator into which a selected legend insert is snapped. Legend inserts are molded thermoplastic and come in a wide variety of legends and colors. The selector switch operator can be instantly set for two or three positions at any time. 2 Push Buttons Surface Mounting, NEMA 1 2 Push Buttons Flush Mounting, NEMA 1B Pilot Devices Mushroom Head 50ZMH mounts on any standard push button operator. The Mushroom Head is red molded thermoplastic, 1 1/2" in diameter, and provides a large operator for emergency stop or similar applications. Mechanical Interlock 50ZAM is a base mounted zinc plate, dichromate dipped, steel assembly. When mounted in conjunction with Duplex Contact Block 50ZAC3 (one NO and one NO) the interlock prevents one contact from being closed while the other contact is closed. 16-180 1 Push Button Surface Mounting 1 Selector Switch Flush Mounting 2 Push Buttons 1 Selector Switch Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1 Pilot Light 2 Push Buttons Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations 5A 600V AC NEMA B600 Selection and ordering data Degree of protection Operator identification 1 unit surface mount-momentary pushbutton Order No. List Price $ 1 unit Packs Unit 1NO - 1NC with common jumper (50ZAC1) 1 50AA3D 49.00 1 NEMA 1 1NO - 1NC with common jumper (50ZAC1) 1 50AA3E 49.00 1 A = Momentary raised pushbutton red, sur- NEMA 1 face, label "STOP" 1NO - 1NC with common jumper (50ZAC1) 1 50AA3F 49.00 1 NEMA 1 1NO - 1NC with common jumper (50ZAC1) 1 50AA3G 58.00 1 A = Momentary flush pushbutton less insert, NEMA 1 surface 1NO - 1NC with common jumper (50ZAC1) 1 50AA3A 47.00 1 A = Momentary flush pushbutton red, surface, label "STOP" NEMA 1 2 NO 2SPST (50ZAC8) 1 50AA3C3 49.00 1 A = 3 position selector switch, surface, label "Off-On" NEMA 1 2 NO 2SPST (50ZAC8) 1 50AA3C6 49.00 1 A = 2/3 selector switch, surface, multiple legends NEMA 1 2 NO 2SPST (50ZAC8) 1 50AA3B9 49.00 1 A = Indicator light, red, surface NEMA 1 120/240V dual voltage 120PSB lamp 1 50BA3Y 115.00 1 A = Indicator light, green, surface NEMA 1 120/240V dual voltage 120PSB lamp 1 50BA3Z 115.00 1 A = Indicator light, less lens, surface NEMA 1 120/240V dual voltage 120PSB lamp 1 50BA32 109.00 1 A = Momentary flush pushbutton green, flush, label "START" NEMA 1B 1NO - 1NC with common jumper (50ZAC1) 1 50AA2D 62.00 1 A = Momentary flush pushbutton red, flush, label "STOP" NEMA 1B 1NO - 1NC with common jumper (50ZAC1) 1 50AA2E 62.00 1 A = Momentary raised pushbutton red, flush, label "STOP" NEMA 1B 1NO - 1NC with common jumper (50ZAC1) 1 50AA2F 62.00 1 A = Momentary flush pushbutton less insert, NEMA 1B flush 1NO - 1NC with common jumper (50ZAC1) 1 50AA2A 60.00 1 A = Momentary flush pushbutton less insert, NEMA 1B flush, chrome plate 1NO - 1NC with common jumper (50ZAC1) 1 50AA6A 66.00 1 NEMA 1B 2 NO 2SPST (50ZAC8) 1 50AA2C3 62.00 1 A = 3 position selector switch, flush, label "Off-On" NEMA 1B 2 NO 2SPST (50ZAC8) 1 50AA2C6 62.00 1 A = 2/3 selector switch, multiple legends, flush NEMA 1B 2 NO 2SPST (50ZAC8) 1 50AA2B9 62.00 1 A = 2/3 selector switch, multiple legends, chrome plate, flush NEMA 1B 2 NO 2SPST (50ZAC8) 1 50AA6B9 68.00 1 A = Indicator light, red, flush NEMA 1B 120/240V dual voltage 1 50BA2Y 127.00 1 A = Indicator light, green, flush NEMA 1B 120/240V dual voltage 1 50BA2Z 127.00 1 A = Indicator light, less lens, flush NEMA 1B 120/240V dual voltage 1 50BA22 121.20 1 A = Indicator light, less lens, chrome plate, flush NEMA 1B 120PSB lamp 1 50BA62 127.00 1 B = Momentary pushbutton green, surface, NEMA 1 label "START" A = Momentary pushbutton red, surface, label "STOP" 1NO, 1NC (50ZAC2) 2 50CA3DE 49.00 1 B = Momentary pushbutton green, surface, NEMA 1 label "START" A = Momentary raised pushbutton red, surface, label "STOP" 1NO, 1NC (50ZAC2) 2 50CA3DF 49.00 1 B = Momentary pushbutton green, surface, NEMA 1 label "START" A = Momentary mushroom head pushbutton red, surface, label "STOP" 1NO, 1NC (50ZAC2) 2 50CA3DG 64.00 1 B = Momentary pushbutton, less insert, surface A = Momentary pushbutton, less insert, surface NEMA 1 1NO, 1NC (50ZAC2) 2 50CA3AA 45.00 1 B = Momentary pushbutton, surface, label "FORWARD" A = Momentary pushbutton, surface, label "REVERSE" NEMA 1 2 NO (50ZAC3) 2 50DA3KL 49.00 1 Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Pilot Devices A = 3 position selector switch, flush, label "HAND-OFF-AUTO" CONTROL PRODUCTS A = 3 position selector switch, surface, label "HAND-OFF-AUTO" 16 2 unit surface mount-momentary pushbutton Number of command points A = Momentary flush pushbutton green, sur- NEMA 1 face, label "START" A = Momentary mushroom head red, surface, label "STOP" 1 unit flush mountmomentary pushbutton Contacts / voltage 16-181 Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations 5A 600V AC NEMA B600 Selection and ordering data 16 CONTROL PRODUCTS Pilot Devices 2 unit flush mountmomentary pushbutton 16-182 Order No. List Price $ Pack Degree of protection Contacts / voltage B = Momentary pushbutton, surface, label "OPEN" A = Momentary pushbutton, surface, label "CLOSE" NEMA 1 2 NO (50ZAC3) 2 50DA3HJ 49.00 1 B = Momentary pushbutton, surface, label "UP" A = Momentary pushbutton, surface, label "DOWN" NEMA 1 2 NO (50ZAC3) 2 50DA3NP 49.00 1 B = Momentary pushbutton, surface, less insert A = Momentary pushbutton, surface, less insert NEMA 1 2 NO (50ZAC3) 2 50DA3AA 45.00 1 B = Momentary pushbutton, surface, label "FORWARD" A = Momentary pushbutton, surface, label "REVERSE" NEMA 1 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA3KL 52.00 1 B = Momentary pushbutton, surface, label "OPEN" A = Momentary pushbutton, surface, label "CLOSE" NEMA 1 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA3HJ 62.00 1 B = Momentary pushbutton, surface, label "UP" A = Momentary pushbutton, surface, label "DOWN" NEMA 1 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA3NP 62.00 1 B = Momentary pushbutton, surface, label "ON" A = Momentary pushbutton, surface, label "OFF" NEMA 1 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA334 62.00 1 B = Momentary pushbutton, less insert surface A = Momentary pushbutton, less insert, surface NEMA 1 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA3AA 58.00 1 B = Momentary pushbutton, surface, label "FORWARD" A = Momentary pushbutton, surface, label "REVERSE" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 2 50EA3KL 73.00 1 B = Momentary pushbutton, surface, label "OPEN" A = Momentary pushbutton, surface, label "CLOSE" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 2 50EA3HJ 73.00 1 B = Momentary pushbutton, surface, label "UP" A = Momentary pushbutton, surface, label "DOWN" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 2 50EA3NP 73.00 1 B = Momentary pushbutton, surface, label "ON" A = Momentary pushbutton, surface, label "OFF" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 2 50EA334 73.00 1 B = Momentary pushbutton, surface, less insert A = Momentary pushbutton, surface, less insert NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 2 50EA3AA 69.00 1 B = Momentary pushbutton green, flush, label "START" A = Momentary pushbutton red, flush, label "STOP" NEMA 1B 1NO, 1NC (50ZAC2) 2 50CA2DE 62.00 1 NEMA 1B B = Momentary pushbutton green, flush, label "START" A = Momentary raised pushbutton red, flush, label "STOP" 1NO, 1NC (50ZAC2) 2 50CA2DF 62.00 1 NEMA 1B B = Momentary pushbutton green, flush, label "START" A = Momentary mushroom head pushbutton red, flush, label "STOP" 1NO, 1NC (50ZAC2) 2 50CA2AA 58.00 1 B = Momentary pushbutton, less insert, flush NEMA 1B A = Momentary pushbutton, less insert, flush 1NO, 1NC (50ZAC2) 2 50CA6AA 64.00 1 Operator identification 2 unit surface mount-momentary pushbutton Number of command points Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 1 unit Unit Discount Schedule PILO Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations 5A 600V AC NEMA B600 Selection and ordering data Order No. List Price $ Packs Degree of protection Contacts / voltage B = Momentary pushbutton, flush, label "FORWARD" A = Momentary pushbutton, flush, label "REVERSE" NEMA 1B 2 NO (50ZAC3) 2 50DA2KL 62.00 1 B = Momentary pushbutton, flush, label "OPEN" A = Momentary pushbutton, flush, label "CLOSE" NEMA 1B 2 NO (50ZAC3) 2 50DA2HJ 62.00 1 B = Momentary pushbutton, flush, label "UP" A = Momentary pushbutton, flush, label "DOWN" NEMA 1B 2 NO (50ZAC3) 2 50DA2NP 62.00 1 B = Momentary pushbutton, less insert, flush NEMA 1B A = Momentary pushbutton, less insert, flush 2 NO (50ZAC3) 2 50DA2AA 58.00 1 B = Momentary pushbutton, less insert, chrome plate, flush A = Momentary pushbutton, less insert, chrome plate, flush NEMA 1B 2 NO (50ZAC3) 2 50DA6AA 62.00 1 B = Momentary pushbutton, flush, label "FORWARD" A = Momentary pushbutton, flush, label "REVERSE" NEMA 1B 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA2KL 73.00 1 B = Momentary pushbutton, flush, label "OPEN" A = Momentary pushbutton, flush, label "CLOSE" NEMA 1B 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA2HJ 73.00 1 B = Momentary pushbutton, flush, label "UP" A = Momentary pushbutton, flush, label "DOWN" NEMA 1B 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA2NP 73.00 1 B = Momentary pushbutton, flush, label "ON" A = Momentary pushbutton, flush, label "OFF" NEMA 1B 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA234 73.00 1 B = Momentary pushbutton, less insert, flush NEMA 1B A = Momentary pushbutton, less insert, flush 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA2AA 69.00 1 B = Momentary pushbutton, less insert, chrome plate, flush A = Momentary pushbutton, less insert, chrome plate, flush NEMA 1B 2 NO mechanically interlocked (50ZA3C w/ 50ZAM) 2 50RA6AA 76.00 1 B = Momentary pushbutton, flush, label "FORWARD" A = Momentary pushbutton, flush, label "REVERSE" NEMA 1B 2 NO, 2 NC (2 - 50ZAC2) 2 50EA2KL 86.00 1 B = Momentary pushbutton, flush, label "OPEN" A = Momentary pushbutton, flush, label "CLOSE" NEMA 1B 2 NO, 2 NC (2 - 50ZAC2) 2 50EA2HJ 86.00 1 B = Momentary pushbutton, flush, label "UP" A = Momentary pushbutton, flush, label "DOWN" NEMA 1B 2 NO, 2 NC (2 - 50ZAC2) 2 50EA2NP 86.00 1 B = Momentary pushbutton, flush, label "ON" A = Momentary pushbutton, flush, label "OFF" NEMA 1B 2 NO, 2 NC (2 - 50ZAC2) 2 50EA234 86.00 1 B = Momentary pushbutton, less insert, flush NEMA 1B A = Momentary pushbutton, less insert, flush 2 NO, 2 NC (2 - 50ZAC2) 2 50EA2AA 82.00 1 NEMA 1B 2 NO, 2 NC (2 - 50ZAC2) 2 50EA6AA 88.00 1 Operator identification 2 unit flush mountmomentary pushbutton Number of command points Pilot Devices Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog CONTROL PRODUCTS Discount Schedule PILO Unit 16 B = Momentary pushbutton, less insert, chrome plate, flush A = Momentary pushbutton, less insert, chrome plate, flush 1 unit 16-183 Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations 5A 600V AC NEMA B600 Selection and ordering data Operator identification 2 unit surface mount-momentary pushbutton Degree of protection B = Momentary pushbutton green, surface, NEMA 1 label "START" A = Maintained selector switch, surface, label "HAND-OFF-AUTO" 1NO, 1NC (50ZAC1) B = Momentary pushbutton less insert, sur- NEMA 1 face A = Maintained selector switch, multiple legends, surface 1NO, 1NC (50ZAC1) 16 CONTROL PRODUCTS 2 50FA3DC3 1 unit 73.00 Unit 1 2 50FA3AB9 73.00 1 2 NO 2SPDT w/ common jumper (50ZAC8) 2 NO 2SPDT w/ common jumper (50ZAC8) 50HA3YC3 180.00 1 NEMA 1 120/240V dual voltage (120PSB lamp) 2 NO 2SPDT w/ common jumper (50ZAC8) 2 50HA32B9 180.00 1 B = Indicator light, green, surface A = Indicator light, red, surface NEMA 1 120/240V dual voltage (120PSB lamp) 2 50GA3ZY 180.00 1 B = Indicator light, less lens, surface A = Indicator light, less lens, surface NEMA 1 120/240V dual voltage (120PSB lamp) 2 50GA322 168.00 1 B = Momentary pushbutton green, flush, label "START" A = Maintained selector switch, flush, label "HAND-OFF-AUTO" NEMA 1B 1NO, 1NC (50ZAC1) 2 50FA2DC3 86.00 1 2 50FA2AB9 84.00 1 2 50FA6AB9 91.00 1 A = Maintained selector switch, multiple legends, surface Pilot Devices Pack 2 B = Indicator light, red, surface 16-184 List Price $ 120/240V dual voltage (120PSB lamp) 2 NO 2SPDT w/ common jumper (50ZAC8) A = Maintained selector switch, surface, label "HAND-OFF-AUTO" 3 unit surface mount Order No. NEMA 1 B = Indicator light, red, surface 2 unit flush mountmomentary pushbutton Contacts / voltage Number of command points 2 NO 2SPDT w/ common jumper (50ZAC8) B = Momentary pushbutton less insert, flush NEMA 1B A = Maintained selector switch, multiple legends, flush 1NO, 1NC (50ZAC1) B = Momentary pushbutton less insert chrome plate, flush A = Maintained selector switch, multiple legends, flush NEMA 1B 1NO, 1NC (50ZAC1) B = Indicator light, red, flush A = Maintained selector switch, flush, label "HAND-OFF-AUTO" NEMA 1B 120/240V dual voltage (120PSB lamp) 2 NO 2SPDT w/ common jumper (50ZAC8) 2 50HA2YC3 189.00 1 NEMA 1B B = Indicator light, less lens, flush A = Maintained selector switch, multiple legends, flush 120/240V dual voltage (120PSB lamp) 2 NO 2SPDT w/ common jumper (50ZAC8) 2 50HA22B9 189.00 1 B = Indicator light, less lens, chrome plate, NEMA 1B flush A = Maintained selector switch, multiple legends, flush 120/240V dual voltage (120PSB lamp) 2 NO 2SPDT w/ common jumper (50ZAC8) 2 50HA62B9 189.00 1 2 NO 2SPDT w/ common jumper (50ZAC8) 2 NO 2SPDT w/ common jumper (50ZAC8) B = Indicator light, green, flush A = Indicator light, red, flush NEMA 1B 120/240V dual voltage (120PSB lamp) 2 50GA2ZY 182.00 1 B = Indicator light, less lens, flush A = Indicator light, less lens, flush NEMA 1B 120/240V dual voltage (120PSB lamp) 2 50GA222 176.00 1 B = Indicator light, less lens, chrome plate, flush A = Indicator light, less lens, chrome plate, flush NEMA 1B 120/240V dual voltage (120PSB lamp) 2 50GA622 182.00 1 C = Momentary pushbutton, surface, label "FORWARD" B = Momentary pushbutton, surface, label "REVERSE" A = Momentary pushbutton, surface, label "STOP" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 1NO - 1NC with common jumper (50ZAC1) 3 50MA3KLE 98.00 1 C = Momentary pushbutton, surface, label "UP" B = Momentary pushbutton, surface, label "DOWN" A = Momentary pushbutton, surface, label "STOP" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 1NO - 1NC with common jumper (50ZAC1) 3 50MA3NPE 98.00 1 C = Momentary pushbutton, surface, label "OPEN" B = Momentary pushbutton, surface, label "CLOSE" A = Momentary pushbutton, surface, label "STOP" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 1NO - 1NC with common jumper (50ZAC1) 3 50MA3HJE 98.00 1 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations 5A 600V AC NEMA B600 Selection and ordering data Order No. List Price $ Pack 1 unit Unit Degree of protection Contacts / voltage C = Momentary pushbutton, surface, label "FAST" B = Momentary pushbutton, surface, label "SLOW" A = Momentary pushbutton, surface, label "STOP" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 1NO - 1NC with common jumper (50ZAC1) 3 50MA3TUE 98.00 1 C = Momentary pushbutton, surface, label "START" B = Momentary pushbutton, surface, label "JOG" A = Momentary pushbutton, surface, label "STOP" NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 1NO - 1NC with common jumper (50ZAC1) 3 50MA3DME 98.00 1 C = Momentary pushbutton, surface, label less insert B = Momentary pushbutton, surface, label less insert A = Momentary pushbutton, surface. label less insert NEMA 1 2 NO, 2 NC (2 - 50ZAC2) 1NO - 1NC with common jumper (50ZAC1) 3 50MA3AAA 92.00 1 C = Momentary pushbutton, surface, label "START" B = Momentary pushbutton, surface, label "STOP" A = Maintained selector switch, surface, label "HAND-OFF-AUTO" NEMA 1 1 NO, 1 NC (50ZAC2) 2 NO, 2 SPST with common jumper (50ZAC8) 3 50LA3DEC3 148.00 1 C = Momentary pushbutton, less insert, sur- NEMA 1 face B = Momentary pushbutton, less insert, surface A = Maintained selector switch, multiple legends, surface 1 NO, 1 NC (50ZAC2) 2 NO, 2 SPST with common jumper (50ZAC8) 3 50LA3AAB9 144.00 1 Operator identification 3 unit surface mount Number of command points NEMA 1 120/240V dual voltage (120PSB lamp) 1 NO, 1 NC (50ZAC2) 3 50JA3YDE 180.00 1 C = Indicator light, green, surface B = Momentary pushbutton, surface, label "START" A = Momentary pushbutton, surface, label "STOP" NEMA 1 120/240V dual voltage (120PSB lamp) 1 NO, 1 NC (50ZAC2) 3 50JA3ZDE 180.00 1 NEMA 1 C = Indicator light, less lens, surface B = Momentary pushbutton, less insert, surface A = Momentary pushbutton, less insert, surface 120/240V dual voltage (120PSB lamp) 1 NO, 1 NC (50ZAC2) 3 50JA32AA 170.00 1 NEMA 1 120/240V dual voltage (120PSB lamp) 2 NO, 2 SPST with common jumper (50ZAC8) 3 50NA3ZYC3 230.00 1 NEMA 1 C = Indicator light, less lens, surface B = Indicator light, less lens, surface A = Maintained selector switch, multiple legends, surface 120/240V dual voltage (120PSB lamp) 2 NO, 2 SPST with common jumper (50ZAC8) 3 50NA322B9 218.00 1 CONTROL PRODUCTS C = Indicator light, green, surface B = Indicator light, red, surface A = Maintained selector switch, surface, label "HAND-OFF-AUTO" 16 C = Indicator light, red, surface B = Momentary pushbutton, surface, label "START" A = Momentary pushbutton, surface, label "STOP" Pilot Devices Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-185 Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations Heavy Duty - 10A 600V NEMA B600 Selection and ordering data 16 CONTROL PRODUCTS Pilot Devices 16-186 Order No. List Price $ Pack 1 unit Unit Degree of protection Contacts / voltage A = Momentary pushbutton, surface, label "START" – Green NEMA 4 1NO - 1NC 1 50HA1E1 213.00 1 A = Momentary pushbutton, surface, label "STOP" – Red NEMA 4 1NO - 1NC 1 50HA1E2 213.00 1 A = Momentary pushbutton, surface, label "RESET" – Green NEMA 4 1NO - 1NC 1 50HA1E4 213.00 1 A = Momentary pushbutton, surface, label "JOG" – Green A = Maintained selector switch, surface, label "SAFE-RUN" A = Maintained selector switch, surface, label "OFF-ON" A = Maintained selector switch, surface, label "JOG-RUN" – Green NEMA 4 1NO - 1NC 1 50HA1E5 213.00 1 NEMA 4 1NO - 1NC 1 50HA1E6 222.00 1 NEMA 4 1NO - 1NC 1 50HA1E7 222.00 1 NEMA 4 1NO - 1NC 1 50HA1E8 222.00 1 A = Maintained selector switch, surface, label "HAND-OFF-AUTO" B = Momentary pushbutton, surface, label "START" – Green A = Momentary pushbutton, surface, label "STOP" – Red NEMA 4 1NO - 1NC 1 50HA1E9 222.00 1 NEMA 4 1NO - 1NC 2 50HA2E1 301.00 1 B = Momentary pushbutton, surface, label "FORWARD" – Green A = Momentary pushbutton, surface, label "REVERSE" – Red NEMA 4 2 50HA2E2 301.00 1 B = Momentary pushbutton,P surface, label "UP" – Green A = Momentary pushbutton, surface, label "DOWN" – Red NEMA 4 2 50HA2E3 301.00 1 B = Momentary pushbutton, surface, label "OPEN" – Green A = Momentary pushbutton, surface, label "CLOSE" – Red NEMA 4 2 50HA2E4 301.00 1 B = Momentary pushbutton, surface, label "FAST" – Green A = Momentary pushbutton, surface, label "SLOW" – Red NEMA 4 2 50HA2E5 301.00 1 C = Momentary pushbutton, surface, label "FORWARD" – Green B = Momentary pushbutton, surface, label "REVERSE" – Green A = Momentary pushbutton, surface, label "STOP" – Red NEMA 4 3 50HA3E1 395.00 1 C = Momentary pushbutton, surface, label "UP" – Green B = Momentary pushbutton, surface, label "DOWN" – Green A = Momentary pushbutton, surface, label "STOP" – Red NEMA 4 3 50HA3E2 395.00 1 C = Momentary pushbutton, surface, label "OPEN" – Green B = Momentary pushbutton, surface, label "CLOSE" – Green A = Momentary pushbutton, surface, label "STOP" – Red NEMA 4 3 50HA3E3 395.00 1 C = Momentary pushbutton, surface, label "START" – Green B = Momentary pushbutton, surface, label "JOG" – Green A = Momentary pushbutton, surface, label "STOP" – Red NEMA 4 3 50HA3E9 395.00 1 C = Momentary pushbutton, surface, label "FAST" – Green B = Momentary pushbutton, surface, label "SLOW" – Green A = Momentary pushbutton, surface, label "STOP" – Red NEMA 4 3 50HA3E4 395.00 1 Operator identification Art to Come Number of command points 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC 1NO - 1NC Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations Standard Duty Station Accessories Selection and ordering data Legend inscription insert for snap-on mounting Inscription Color Order No. Close Down Fast Forward High Hoist Jog Low Lower Off On Open Reverse Slow Start Stop Stop (raised) Up Orange Orange Black Green Black Green Black Black Orange Red Green Green Orange Black Green Red Red Green 50D53493005 50D53493010 50D53493013 50D53493006 50D53493015 50D53493011 50D53493008 50D53493016 50D53493012 50D53493018 50D53493017 50D53493004 50D53493007 50D53493014 50D53493001 50D53493002 50D53493003 50D53493009 Version Suitable for Mushroom head Padlock attachment Mechanical interlock kit 50ZAC2 50ZAC8 50ZAC3 Contact blocks 1NO, 1NC 2NO, 2SPST 1NO, 1NC 1NO, 1NO Order No. Red 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Pack Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 List Price $ 1 unit Pack Unit Used only for raised buttons 50ZMH 50ZAL 50ZAM 16.40 24.50 12.40 1 1 1 Single button Selector switch Two button Two button 50ZAC1 50ZAC8 50ZAC2 50ZAC3 24.50 24.50 24.50 24.50 1 1 1 1 50ZAC6 60.00 1 50ZPL01 50ZPL02 6.20 6.20 1 1 16 50ZAC1 Color List Price $ 1 unit Pilot light lens Red Green Pendant Bracket 1 & 2 unit station 3 unit station 50ZAP2 50ZAP3 8.20 8.20 1 1 Replacement lamps Slide base, lamp type 120PSB Class 50 type 1, 1B 120V 50D21983001 8.50 1 CONTROL PRODUCTS 120/240V Dual Voltage, no lens Pilot light Heavy Duty Station Accessories Version Suitable for Color Order No. Pushbutton caps NEMA 4 control stations NEMA 4 control stations Red Black BHP15X BHP16X List Price $ 1 unit 66.00 66.00 Pack Unit 1 1 Pilot Devices Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-187 Pushbutton Units and Indicator Lights Class 50 Standard Duty Pushbutton Stations Standard Duty - 5A 600V NEMA B600 1 Unit Station Surface Mounting—Type 1 1 Unit Station Flush Mounting—Type 1B 2 Pushbutton Stations Surface Mounting—Type 1 2 Pushbutton Stations Flush Mounting—Type 1B 2 Unit Stations Surface Mounting—Type 1 2 Unit Station Flush Mounting—Type 1B CONTROL PRODUCTS 16 Dimension drawings 1 Unit Stations—Type 4 Pilot Devices 3 Unit Stations Surface Mounting 16-188 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Pushbutton Complete Units • Positive Indexing Selectors standard, which improve contact fidelity. Contact blocks are heavy duty rated NEMA A600 and suitable for applications down to 5V/1MA solid state outputs. Molded bodies and pushers resist arcing and tracking. All units have stainless steel springs that resist corrosion and provide strong contact pressure. Captive mounting screws speed panel assembly. • Bifurcated Movable Contacts Push Pull Operators • Attractive Chrome Plating Push Pull Operators combine two or three functions in one unit. The maintained operator has two positions, typically pull to start, push to stop. The momentary operator with three positions provides spring return from both pull and push positions. These units are also available with a pilot light. • Accessories see page 16-211. 2 Button Maintained Operator • Legend Plates see page 16-219. Maintained Push Buttons consist of two push buttons and a latching assembly. When actuated the button remains depressed and is freed only by the release operator to which it is linked. The button assembly adjusts for mounting from a 1 13⁄16 inch to a 2 5⁄8 inch center. • Enclosures see page 16-220. Oil tight pilot controls and accessories are designed to provide long, trouble free service in the most demanding industrial applications. These controls are oil and dust tight and meet Type 3, 4, 12 and 13 specifications. Rugged Transformer Type Pilot Lights Industrial control operators are durable one piece castings. Heavy duty plastic buttons resist oils and corrosion. Silver contacts with gold flashing carry heavy duty ratings while allowing for low-voltage applications. Transformer Type Pilot Lights are available with a 120, 240, 480 or 600 Volt primary (50/ 60 Hertz) and a separate secondary winding which supplies reduced voltage to a miniature bayonet base 6 Volt lamp. These units are suitable for applications where vibration is present and long bulb life is desirable. Features • Octagonal Mounting Nuts • Meets Type 1, 3, 4, 12, 13 and Automotive Standards • Heavy Duty Rated NEMA A600 Contacts • Boots Not Required for Type 4 • UL Listed File # E22655 • CSA Certified File # LR6535 • Touchsafe Terminals Application Flexible Pilot controls add luster to panels. Chrome plating covers exposed metal parts. Push Button Operators The Operator Base consists of a durable, one piece casting equipped with a heavy duty actuator with a stainless steel spring, a neoprene actuator sealing ring to prevent oil and dust from penetrating to the contact blocks, a neoprene gasket to seal operator mounting hole and a chrome plated lock nut. Break 60 30 15 12 7200 6 3 1.5 1.2 720 Ordering Information • Selector Position and Contact Operation page 16-209. Full Voltage Type Pilot Lights Full Voltage Pilot Lights are available for 6, 12, 24, 120 and 240 Volt AC and DC applications. The 240 Volt pilot light is supplied with a 120 Volt lamp and a voltage dropping resistor LED Type Pilot Lights LED’s (light emitting diodes) can be used in pilot lights instead of incandescent bulbs because of their long life (up to 10 years), resistance to vibration and ambient sensitivity. Selector Operators The Mushroom Head base construction is identical to the push button base. The actuator is molded of high impact material for either a 1 5⁄8 inch or 2 1⁄2 inch diameter molded head. Selector Operators have positive action indexing. Operators are available with either a short or long lever. The molded black lever is designed to accept a color insert. A white insert is provided as standard. Each operator is equipped with a cam to actuate plungers of contact blocks assembled behind the operator. Two, three and four position operators are available with seven different cams. Contact Blocks Lever color inserts are available in 8 colors. Mushroom Head Push Button Operators Make 120 240 480 600 VA CONTROL PRODUCTS Industrial Appearance Volts 16 Accessories modify standard push buttons, selector switches and pilot lights. Building block construction of contact blocks makes possible many circuitry combinations. Electrical Ratings NEMA AC Ratings 50/60Hz NEMA A600 10 Continuous Amps Contact Blocks have double break bifurcated silver contacts, with gold flashing as Pilot Devices Pilot Light Push Button Selector Operator Selector Push Operation Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-189 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Pushbutton Complete Units Selection and ordering data Momentary Version Color of actuator Contact blocks Flush cap order no.1) Extended cap List order no.1) Price Mushroom head List order no.1) Price Pushbutton unit with assembled contact blocks black red green yellow 1 NO 1 NO 1 NO 1 NO 52PA8A1K 52PA8A2K 52PA8A3K 52PA8A4K 52PA8B1K 52PA8B2K 52PA8B3K 52PA8B4K 34.50 34.50 34.50 34.50 52PB9 52PB9 52PB9 52PB9 1K 2K 3K 4K 59.00 59.00 59.00 59.00 blue gray orange 1 NO 1 NO 1 NO 52PA8A5K 52PA8A6K 52PA8A8K 52PA8B5K 52PA8B6K 52PA8B8K 34.50 34.50 34.50 52PB9 5K 52PB9 6K 52PB9 8K 59.00 59.00 59.00 black red green yellow 1 NC 1 NC 1 NC 1 NC 52PA8A1J 52PA8A2J 52PA8A3J 52PA8A4J 52PA8B1J 52PA8B2J 52PA8B3J 52PA8B4J 34.50 34.50 34.50 34.50 52PB9 52PB9 52PB9 52PB9 1J 2J 3J 4J 59.00 59.00 59.00 59.00 blue gray orange 1 NC 1 NC 1 NC 52PA8A5J 52PA8A6J 52PA8A8J 52PA8B5J 52PA8B6J 52PA8B8J 34.50 34.50 34.50 52PB9 5J 52PB9 6J 52PB9 8J 59.00 59.00 59.00 black red green yellow 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 52PA8A1A 52PA8A2A 52PA8A3A 52PA8A4A 52PA8B1A 52PA8B2A 52PA8B3A 52PA8B4A 47.00 47.00 47.00 47.00 52PB9 52PB9 52PB9 52PB9 1A 2A 3A 4A 71.00 71.00 71.00 71.00 blue gray orange 1 NO + 1 NC 52PA8A5A 1 NO + 1 NC 52PA8A6A 1 NO + 1 NC 52PA8A8A 52PA8B5A 52PA8B6A 52PA8B8A 47.00 47.00 44.00 52PB9 5A 52PB9 6A 52PB9 8A 71.00 71.00 71.00 black red green yellow 2 NO 2 NO 2 NO 2 NO 52PA8A1F 52PA8A2F 52PA8A3F 52PA8A4F 52PA8B1F 52PA8B2F 52PA8B3F 52PA8B4F 47.00 47.00 47.00 47.00 52PB9 52PB9 52PB9 52PB9 1F 2F 3F 4F 71.00 71.00 71.00 71.00 blue gray orange 2 NO 2 NO 2 NO 52PA8A5F 52PA8A6F 52PA8A8F 52PA8B5F 52PA8B6F 52PA8B8F 47.00 47.00 47.00 52PB9 5F 52PB9 6F 52PB9 8F 71.00 71.00 71.00 black red green yellow 2 NC 2 NC 2 NC 2 NC 52PA8A1G 52PA8A2G 52PA8A3G 52PA8A4G 52PA8B1G 52PA8B2G 52PA8B3G 52PA8B4G 47.00 47.00 47.00 47.00 52PB9 52PB9 52PB9 52PB9 1G 2G 3G 4G 71.00 71.00 71.00 71.00 blue gray orange 2 NC 2 NC 2 NC 52PA8A5G 52PA8A6G 52PA8A8G 52PA8B5G 52PA8B6G 52PA8B8G 47.00 47.00 47.00 52PB9 5G 52PB9 6G 52PB9 8G 71.00 71.00 71.00 black red green yellow 2 NO + 2 NC 2 NO + 2 NC 2 NO + 2 NC 2 NO + 2 NC 52PA8A1B 52PA8A2B 52PA8A3B 52PA8A4B 52PA8B1B 52PA8B2B 52PA8B3B 52PA8B4B 72.00 72.00 72.00 72.00 52PB9 52PB9 52PB9 52PB9 1B 2B 3B 4B 96.00 96.00 96.00 96.00 blue gray orange 2 NO + 2 NC 52PA8A5B 2 NO + 2 NC 52PA8A6B 2 NO + 2 NC 52PA8A8B 52PA8B5B 52PA8B6B 52PA8B8B 72.00 72.00 72.00 52PB9 5B 52PB9 6B 52PB9 8B 96.00 96.00 96.00 $ $ Pack Unit 1 Pushbutton with flush cap Order no. change Small operating head - 1 5/8" (41.3 mm) Large operating head - 2.5" (63.5 mm) Pilot Devices 1 1 Pushbutton with 1 5/8" mushroom head CONTROL PRODUCTS 16 Pushbutton with extended cap 1 1 1 D E 1) For other contact block assemblies replace the 8th digit of the catalog number as follows: C = 3 NO + 3 NC D = 4 NO + 4 NC E = 1 NC (EB) H = 1 NO (EM) 16-190 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Push Pull Operators Selection and ordering data Version 2 position push-pull 52PA2A2A 52PA2ACA 52PA2V2A 52PA2W2A 52PA3W2U Order no. List Price $ Order no. List Price $ Pack Unit 2 Position Push Pull Maintained, Non Illuminated Metal Mushroom Head, 1 5/8" (41.3 mm) red green chrome 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2A2A 52PA2A3A 52PA2ACA 98.00 98.00 98.00 Small Plastic Mushroom Head, 1 5/8" (41.3 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2W1A 52PA2W2A 52PA2W3A 88.00 88.00 88.00 Large Plastic Mushroom Head, 2 1/2" (63.5 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2V1A 52PA2V2A 52PA2V3A 106.00 106.00 106.00 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA3A2U 52PA3A3U 52PA3ACU 96.00 96.00 96.00 3 Position Push Pull Momentary, Non-Illuminated (Spring return to center-pull to start, push to stop)1) Metal Mushroom Head, red 1 5/8" (41.3 mm) green chrome Small Plastic Mushroom Head, 1 5/8" (41.3 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA3W1U 52PA3W2U 52PA3W3U 96.00 96.00 96.00 Large Plastic Mushroom Head, 2 1/2" (63.5 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA3V1U 52PA3V2U 52PA3V3U 106.00 106.00 106.00 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO Operators with incandescent lamp 52PA2DNA 52PA2D2A 52PA2D3A 52PA2D9A 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 1 119.00 137.00 137.00 137.00 Operators with LED lamp*****2) ***** 52PE2D2A 52PE2D3A 52PE2D9A ––––– 151.00 151.00 151.00 52PA2DRA 52PA2DSA 52PA2DTA 137.00 137.00 137.00 52PE2DRA 52PE2DSA 52PE2DTA 151.00 151.00 151.00 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2GNA 52PA2G2A 52PA2G3A 52PA2G9A 119.00 137.00 137.00 137.00 ***** 52PE2G2A 52PE2G3A 52PE2G9A ––––– 151.00 151.00 151.00 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2GRA 52PA2GSA 52PA3GTA 137.00 137.00 137.00 52PE2GRA 52PE2GSA 52PE2GTA 151.00 151.00 151.00 240V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2HNA 52PA2H2A 52PA2H3A 52PA2H9A 119.00 137.00 137.00 137.00 ***** 52PE2H2A 52PE2H3A 52PE2H9A ––––– 151.00 151.00 151.00 1 480V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2JNA 52PA2J2A 52PA2J3A 52PA2J9A 119.00 137.00 137.00 137.00 ***** 52PE2J2A 52PE2J3A 52PE2J9A ––––– 151.00 151.00 151.00 1 600V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PA2KNA 52PA2K2A 52PA2K3A 52PA2K9A 119.00 137.00 137.00 137.00 ***** 52PE2K2A 52PE2K3A 52PE2K9A ––––– 151.00 151.00 151.00 1 full red full green full amber 120V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber full red full green full amber Discount Schedule PILO 1 Pilot Devices 1) Blocks cannot be interchanged (start-stop circuit). 1 CONTROL PRODUCTS 2 Position Push Pull Maintained, Illuminated 24V Full Voltage, type 757, or 24V less operating head LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 52PA2D2A 52PA2DRA Contact blocks 16 2 position push pull with fully illuminated mushroom head Color of actuator 2) LED color must match lens color. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-191 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Push Pull Operators Selection and ordering data Order no. List operators with Price incandescent lamp $ Order no. operators with LED type2) List Price Pack $ Unit 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA3DNU 52PA3D2U 52PA3D3U 52PA3D9U 119.00 137.00 137.00 137.00 ***** 52PE3D2U 52PE3D3U 52PE3D9U ––––– 151.00 151.00 151.00 1 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA3DRU 52PA3DSU 52PA3DTU 137.00 137.00 137.00 52PE3DRU 52PE3DSU 52PE3DTU 151.00 151.00 151.00 1 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA3GNU 52PA3G2U 52PA3G3U 52PA3G9U 119.00 137.00 137.00 137.00 ***** 52PE3G2U 52PE3G3U 52PE3G9U ––––– 151.00 151.00 151.00 1 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA3GRU 52PA3GSU 52PA3GTU 137.00 137.00 137.00 52PE3GRU 52PE3GSU 52PE3GTU 151.00 151.00 151.00 1 240V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA3HNU 52PA3H2U 52PA3H3U 52PA3H9U 119.00 137.00 137.00 137.00 ***** 52PE3H2U 52PE3H3U 52PE3H9U ––––– 151.00 151.00 151.00 1 480V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA3JNU 52PA3J2U 52PA3J3U 52PA3J9U 119.00 137.00 137.00 137.00 ***** 52PE3J2U 52PE3J3U 52PE3J9U ––––– 151.00 151.00 151.00 1 600V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA3KNU 52PA3K2U 52PA3K3U 52PA3K9U 119.00 137.00 137.00 137.00 ***** 52PE3K2U 52PE3K3U 52PE3K9U ––––– 151.00 151.00 151.00 1 Version 3 position push-pull illuminated Color of actuator 3 Position Push Pull Momentary, Illuminated, spring return to center 1) 24V Full Voltage 757 type, or 24V less operating head LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber full red full green full amber 52PA3D2U 120V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber full red full green full amber Pilot Devices CONTROL PRODUCTS 16 52PA3DRU Contact blocks 1) Blocks cannot be interchanged (start-stop circuit). 2) LED color must match lens color. 16-192 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Selector Switch Complete Units Selection and ordering data Version Lever type Contact blocks Cam1) Order no. List Price Pack $ unit Selector Switches with 2 switching positions Maintained operation Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1NO 1NC 1NO + 1NC 1NO 1NC 1NO + NC A A A A A A 52SA2AABK1 52SA2AABJ1 52SA2AABA1 52SB2AABK1 52SB2AABJ1 52SB2AABA1 42.50 42.50 55.00 42.50 42.50 55.00 1 Spring return from right operation Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1NO 1NC 1NO + 1NC 1NO 1NC 1NO + 1NC A A A A A A 52SA2ACBK1 52SA2ACBJ1 52SA2ACBA1 52SB2ACBK1 52SB2ACBJ1 52SB2ACBA1 59.00 59.00 72.00 59.00 59.00 72.00 1 Short lever assembled selector switch Selector Switches with 3 switching positions 1NO + 1NC 2NC + 1NO 2NO + 2NC 1NO + 1NC 2NC + 1NO 2NO + 2NC C G C C G C 52SA2CABA1 52SA2GABJ2K1 52SA2CABA2 52SB2CABA1 52SB2GABJ2K1 52SB2CABA2 55.00 67.00 80.00 55.00 67.00 80.00 1 Spring return from right2) Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1NO + 1NC 2NC + 1NO 2NO + 2NC 1NO + 1NC 2NC + 1NO 2NO + 2NC C G C C G C 52SA2CCBA1 52SA2GCBJ2K1 52SA2CCBA2 52SB2CCBA1 52SB2GCBJ2K1 52SB2CCBA2 72.00 84.00 96.00 72.00 84.00 96.00 1 Spring return from right & left operation Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1NO + 1NC 2NC + 1NO 2NO + 2NC 1NO + 1NC 2NC + 1NO 2NO + 2NC C G C C G C 52SA2CDBA1 52SA2GDBJ2K1 52SA2CDBA2 52SB2CDBA1 52SB2GDBJ2K1 52SB2CDBA2 72.00 84.00 96.00 72.00 84.00 96.00 1 Assembled keyed selector switch Key-operated selector switches, 2 switching positions Maintained operation Key removable in left positions 1NO Key removable in left positions 1NC Key removable in left positions 1NO + 1NC A A A 52SC6AFK1 52SC6AFJ1 52SC6AFA1 92.00 92.00 105.00 1 Key removable in left positions 1NO Key removable in left positions 1NC Key removable in left positions 1NO + 1NC A A A 52SC6AXK1 52SC6AXJ1 52SC6AXA1 108.00 108.00 121.00 1 Key-operated selector switches, 3 switching positions Maintained operation Key removable in all positions 1NC + 1NO Key removable in all positions 2NC + 1NO Key removable in all positions 2NO + 2NC C G C 52SC6CEA1 52SC6GEJ2K1 52SC6CEA2 105.00 117.00 129.00 1 Key removable in all positions 1NO + 1NC Key removable in all positions 2NC + 1NO Key removable in all positions 2NO + 2NC C G C 52SC6CZA1 52SC6GZJ2K1 52SC6CZA2 121.00 133.00 145.00 1 Spring return from right & left operation Key removable in all positions 1NO + 1NC Key removable in all positions 2NC + 1NO Key removable in all positions 2NO + 2NC C G C 52SC6CVA1 52SC6GVJ2K1 52SC6CVA2 121.00 133.00 145.00 1 Spring return from right operation Spring return from right operation3) CONTROL PRODUCTS Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 16 Maintained operation Long lever assembled selector switch Pilot Devices 1) For contact operation, see cam selection table on page 16-209. 2) Spring return from left available by substituting "BB" for "CB" in the order number. Eg. 52SA2CBBA1. Discount Schedule PILO 3) Spring return from left available by substituting "CY" for "CZ" in the order number. Eg. 52SC6CYA1. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-193 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Indicator Light Operators Selection and ordering data Version Color of actuator Order no. List Price Operators with Incandescent lamp $ Order no. Operators with LED lamp 3) List Price Pack $ Unit Indicator light with plastic lens Full voltage type AC/DC 1) 2) 6-8V with 755 type, or 6V LED red green amber less lens 52PA4B2 52PA4B3 52PA4B9 52PA4BN 72.00 72.00 72.00 66.00 12V with 756 type red green amber less lens 52PA4C2 52PA4C3 52PA4C9 52PA4CN 72.00 72.00 72.00 66.00 24V with 757 type, or 24V LED red green amber less lens 52PA4D2 52PA4D3 52PA4D9 52PA4DN 72.00 72.00 72.00 66.00 52PE4D2 52PE4D3 52PE4D9 — 86.00 86.00 86.00 ––––– 1 120V with 120MB type, or 120V LED red green amber less lens 52PC4E2 52PC4E3 52PC4E9 52PC4EN 72.00 72.00 72.00 66.00 52PE4E2 52PE4E3 52PE4E9 — 86.00 86.00 86.00 ––––– 1 120V with 6V 755 type lamp, or 6V LED red green amber less lens 52PA4G2 52PA4G3 52PA4G9 52PA4GN 88.00 88.00 88.00 82.00 52PE4G2 52PE4G3 52PE4G9 — 102.00 102.00 102.00 ––––– 1 240V with 6V 755 type lamp, or 6V LED red green amber less lens 52PA4H2 52PA4H3 52PA4H9 52PA4HN 88.00 88.00 88.00 82.00 52PE4H2 52PE4H3 52PE4H9 — 102.00 102.00 102.00 ––––– 1 277V with 6V 755 type lamp, or 6V LED red green amber less lens 52PA4T2 52PA4T3 52PA4T9 52PA4TN 88.00 88.00 88.00 82.00 52PE4T2 52PE4T3 52PE4T9 — 102.00 102.00 102.00 ––––– 1 480V with 6V 755 type lamp, or 6V LED red green amber less lens 52PA4J2 52PA4J3 52PA4J9 52PA4JN 88.00 88.00 88.00 82.00 52PE4J2 52PE4J3 52PE4J9 — 102.00 102.00 102.00 ––––– 1 600V with 6V 755 type lamp, or 6V LED red green amber less lens 52PA4K2 52PA4K3 52PA4K9 52PA4KN 88.00 88.00 88.00 82.00 52PE4K2 52PE4K3 52PE4K9 — 102.00 102.00 102.00 ––––– 1 red green amber less lens 52PC4N2 52PC4N3 52PC4N9 52PC4NN 72.00 72.00 72.00 66.00 52PE4N2 52PE4N3 52PE4N9 — 86.00 86.00 86.00 ––––– 1 Pilot light 52PE4B2 52PE4B3 52PE4B9 — 86.00 86.00 86.00 1 1 CONTROL PRODUCTS 16 Indicator light with plastic lens Transformer type AC 1) 2) Indicator light with plastic lens Resistor type AC/DC 1) 2) 240V with 120V 120MB type lamp, or 120V LED Color code table: blue clear white 5 A B Pilot Devices 5 A B 1) All illuminated devices come with std. Touchsafe shield per UL stds. 16-194 2) For factory installed glass lens, replace the 5th character with "5". 3) LED color must match lens color. Consult Factory for Neon types. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Push to Test Units Selection and ordering data Version Color of actuator Contact blocks Order no. List Price Operators with Incandescent lamp $ Order no. List Price Pack Operators with LED lamp 2) $ Unit Illuminated pushbuttons/Push to test indicator light with plastic lens Full voltage type AC/DC 1)3) Push to test/illuminated pushbutton 6-8V with 755 type, or 6V LED red green amber less lens 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 52PA6B2A 52PA6B3A 52PA6B9A 52PA6BNA 96.00 96.00 96.00 91.00 52PE6B2A 52PE6B3A 52PE6B9A — 110.00 110.00 110.00 ––––– 1 24V with 757 type, or 24V LED red green amber less lens 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 52PA6D2A 52PA6D3A 52PA6D9A 52PA6DNA 96.00 96.00 96.00 91.00 52PE6D2A 52PE6D3A 52PE6D9A — 110.00 110.00 110.00 ––––– 1 120V with 6V 755 type lamp, or 6V LED red green amber less lens 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA6G2A 52PA6G3A 52PA6G9A 52PA6GNA 112.00 112.00 112.00 107.00 52PE6G2A 52PE6G3A 52PE6G9A — 126.00 126.00 126.00 ––––– 1 240V with 6V 755 type lamp, or 6V LED red green amber less lens 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA6H2A 52PA6H3A 52PA6H9A 52PA6HNA 112.00 112.00 112.00 107.00 52PE6H2A 52PE6H3A 52PE6H9A — 126.00 126.00 126.00 ––––– 1 480V with 6V 755 type lamp, or 6V LED red green amber less lens 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA6J2A 52PA6J3A 52PA6J9A 52PA6JNA 112.00 112.00 112.00 107.00 52PE6J2A 52PE6J3A 52PE6J9A — 126.00 126.00 126.00 ––––– 1 600V with 6V 755 type lamp, or 6V LED red green amber less lens 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA6K2A 52PA6K3A 52PA6K9A 52PA6KNA 112.00 112.00 112.00 107.00 52PE6K2A 52PE6K3A 52PE6K9A — 126.00 126.00 126.00 ––––– 1 120V with 24V 757 type lamp, or 24V LED red green amber less lens 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA6M2A 52PA6M3A 52PA6M9A 52PA6MNA 96.00 96.00 96.00 91.00 52PE6M2A 52PE6M3A 52PE6M9A — 110.00 110.00 110.00 ––––– 1 240V with 24V 757 type lamp, or 24V LED red green amber less lens 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PA6N2A 52PA6N3A 52PA6N9A 52PA6NNA 96.00 96.00 96.00 91.00 52PE6N2A 52PE6N3A 52PE6N9A — 110.00 110.00 110.00 ––––– 1 52PA6D2A Illuminated pushbuttons/Push to test indicator light with plastic lens - Transformer type AC 1)3) 52PA6G2A 16 CONTROL PRODUCTS Push to test indicator light with plastic lens - Resistor type AC/DC 3) Color code table: blue clear white 5 A B 5 A B Wiring Diagrams Illuminated Push Button Push to Test Pilot Devices 1) All illuminated devices come with std. Touch-safe shield per UL stds. 2) LED color must match lens color. Consult Factory for Neon types. Discount Schedule PILO 3) For factory installed lens guard, add suffix "V". Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-195 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Pushbutton Operators Only Selection and ordering data Version Color of actuator Order no. Pushbutton with flush cap black red green yellow 52PA8A1 52PA8A2 52PA8A3 52PA8A4 22.00 22.00 22.00 22.00 blue gray orange less cap kit with all colors 52PA8A5 52PA8A6 52PA8A8 52PA8 52PA8AN 22.00 22.00 22.00 20.50 25.50 b l a ck red green yellow 52PA8B1 52PA8B2 52PA8B3 52PA8B4 22.00 22.00 22.00 22.00 blue gray orange less cap kit with all colors 52PA8B5 52PA8B6 52PA8B8 52PA8 52PA8BN 22.00 22.00 22.00 20.50 25.50 black red green yellow 52PB9D1 52PB9D2 52PB9D3 52PB9D4 46.50 46.50 46.50 46.50 blue gray orange less cap kit with all colors 52PB9D5 52PB9D6 52PB9D8 52PB9 52PB9DN 46.50 46.50 46.50 38.50 49.00 black red 52PB9E1 52PB9E2 55.00 55.00 green yellow 52PB9E3 52PB9E4 55.00 55.00 blue gray orange less cap less cap with lens kit 52PB9E5 52PB9E6 52PB9E8 52PB9 52PB9EN 55.00 55.00 55.00 38.50 49.00 Metal Mushroom Head, 1 5/8" (41.3 mm) (Threaded) red green chrome 52PA2A2 52PA2A3 52PA2AC 73.00 73.00 73.00 1 Small Plastic Mushroom Head, 1 5/8" (41.3 mm) (Set Screw) black red green 52PA2W1 52PA2W2 52PA2W3 63.00 63.00 63.00 1 Large Plastic Mushroom Head, 2 1/2" (63.5 mm) (Set Screw) black red green 52PA2V1 52PA2V2 52PA2V3 71.00 71.00 71.00 1 Flush pushbutton operator Pushbutton with extended cap CONTROL PRODUCTS 16 Pushbutton with mushroom cap 1 5/8" (41.3mm) Pushbutton with mushroom cap 2 1/2" (63.5mm) List Price Pack $ Unit 1 1 1 1 2 position push pull operator Pilot Devices 2 position push pull maintained, non illuminated 16-196 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Selector Switch Operators Selection and ordering data Version Lever type Input Order no. Color of Cam lever Code 2) Voltage insert List Price Pack $ unit Selector Switches with 2 switching positions Non-Illuminated, short lever Non-Illuminated, long lever Maintained operation Spring return from right operation White White A A 52SA2AAB 30.50 52SB2AAB 30.50 1 Illuminated, short lever 1) with full voltage 24V, 757 type lamp A 24V 52SA7ADN 73.00 1 Illuminated, short lever 1) with 50/60 Hz transformer 6V, 755 type lamp A A A 120V 240V 24V 52SA7AGN 91.00 52SA7AHN 91.00 52SA7ALN 91.00 1 Non-Illuminated, short lever Non-Illuminated, long lever White White A A 52SA2ACB 47.00 52SB2ACB 47.00 1 White White White White White White White White White White B B C 3) C 3) D D E E G G 52SA2BAB 52SB2BAB 52SA2CAB 52SB2CAB 52SA2DAB 52SB2DAB 52SA2EAB 52SB2EAB 52SA2GAB 52SB2GAB 30.50 30.50 30.50 30.50 30.50 30.50 30.50 30.50 30.50 30.50 1 Selector Switches with 3 switching positions Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Maintained operation Illuminated, short lever 1) with full voltage 24V, 757 type lamp Illuminated, short lever 1) with 50/60 Hz transformer 6V, 755 type lamp 24V 24V 52SA7BDN 73.00 52SA7CDN 73.00 1 B C 3) B C 3) B C 120V 120V 240V 240V 24V 24V 52SA7BGN 52SA7CGN 52SA7BHN 52SA7CHN 52SA7BLN 52SA7CLN 91.00 91.00 91.00 91.00 91.00 91.00 1 White White White White White White White White White White B B C 3) C 3) D D E E G G 52SA2BCB 52SB2BCB 52SA2CCB 52SB2CCB 52SA2DCB 52SB2DCB 52SA2ECB 52SB2ECB 52SA2GCB 52SB2GCB 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 1 Spring return from left operation Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever White White White White White White White White White White B B C 3) C 3) D D E E G G 52SA2BBB 52SB2BBB 52SA2CBB 52SB2CBB 52SA2DBB 52SB2DBB 52SA2EBB 52SB2EBB 52SA2GBB 52SB2GBB 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 1 Spring return from left and right operation Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever White White White White White White White White White White B B C 3) C 3) D D E E G G 52SA2BDB 52SB2BDB 52SA2CDB 52SB2CDB 52SA2DDB 52SB2DDB 52SA2EDB 52SB2EDB 52SA2GDB 52SB2GDB 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 1 White White H H 52SA2HAB 30.50 52SB2HAB 30.50 1 Pilot Devices Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever Non-Illuminated, short lever Non-Illuminated, long lever CONTROL PRODUCTS Spring return from right operation 16 B C 3) Selector Switches with 4 switching positions Maintained operation 1) Illuminated selector switches are provided without lenses. Lens kit must be ordered separately on page 16-211. Discount Schedule PILO Non-Illuminated, short lever Non-Illuminated, long lever 2) For contact operation, see cam selelction chart on page 16-209. 3) The C cam is limited to 4 contact blocks, 1 or 2 pole. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-197 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Selector Switch Operators Selection and ordering data Version Button Position Color of Cam Order no. lever insert Code 2) List Price Pack $ unit Selector Pushbutton Operators NEMA 12/13 only Flush type cap 2 Black Black Black P Q R 52SA3P1 52SA3Q1 52SA3R1 47.00 47.00 47.00 1 Flush 2 Red Red Red P Q R 52SA3P2 52SA3Q2 52SA3R2 47.00 47.00 47.00 1 Flush 3 Black Red S S 52SA3S1 52SA3S2 47.00 47.00 1 Extended 2 Black Black Black P Q R 52SA4P1 52SA4Q1 52SA4R1 47.00 1 47.00 47.00 Extended 2 Red Red Red P Q R 52SA4P2 52SA4Q2 52SA4R2 47.00 47.00 47.00 1 Extended 3 Black Red S S 52SA4S1 52SA4S2 47.00 47.00 1 Pilot Devices CONTROL PRODUCTS 16 1/2" raised type cap Flush 1) For contact operation, see cam selection chart on page 16-209. 16-198 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Selector Switch Operators Selection and ordering data Version Key removal position Lock No. 2 Pos spring return from right to center Left 501CH Key-operated selector Switches with 2 switching positions Maintained operation B oth 501CH Left 501CH Key-operated selector Switches with 3 switching positions Maintained operation A ll 501CH Spring return from left and right operation Right 501CH Center 501CH Left and right 501CH Left and center 501CH Right and center 501CH Center 501CH Left and center 501CH Center 501CH Right 501CH Right and center 501CH Center 501CH A 52SC6AX A A 52SC6AE 52SC6AF 80.00 80.00 1 B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G B C 2) D E G 52SC6BE 52SC6CE 52SC6DE 52SC6EE 52SC6GE 52SC6BF 52SC6CF 52SC6DF 52SC6EF 52SC6GF 52SC6BG 52SC6CG 52SC6DG 52SC6EG 52SC6GG 52SC6BH 52SC6CH 52SC6DH 52SC6EH 52SC6GH 52SC6BJ 52SC6CJ 52SC6DJ 52SC6EJ 52SC6GJ 52SC6BK 52SC6CK 52SC6DK 52SC6EK 52SC6GK 52SC6BM 52SC6CM 52SC6DM 52SC6EM 52SC6GM 52SC6BU 52SC6CU 52SC6DU 52SC6EU 52SC6GU 52SC6BZ 52SC6CZ 52SC6DZ 52SC6EZ 52SC6GZ 52SC6BT 52SC6CT 52SC6DT 52SC6ET 52SC6GT 52SC6BW 52SC6CW 52SC6DW 52SC6EW 52SC6GW 52SC6BY 52SC6CY 52SC6DY 52SC6EY 52SC6GY 52SC6BV 52SC6CV 52SC6DV 52SC6EV 52SC6GV 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 80.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 96.00 1 1) For contact operation, see cam selection chart on page 16-209. 2) C cam limited to 4 single or double pole blocks on spring return operators. Discount Schedule PILO 1 1 1 1 1 1 1 1 1 1 1 Pilot Devices .............................................................................................. 5 Lock types keyed different from standard - up to 25 different keys To order special locks for keyed selector switches, append #550CH X298 #549CH corresponding 'X' suffix to part number. (Same list price as standard key) X299 #548CH X300 Ordering example #547CH X301 52SC6AEX298 #506CH X302 1 CONTROL PRODUCTS Spring return from left operation 501CH List Pack Price $ unit 80.00 1 16 Spring return from right operation Left Cam Order no. Code 1) 3) 1 3) Change the "6" to a "5" in the fifth position and add suffix "X", 25 diff. available. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-199 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Special Devices Selection and ordering data Version Ohms / color Order no. Potentiometer operator 2 Watts (Type 12/3 only) 50 250 500 1K 2.5 K 5K 10 K 15 K 25 K 100 K 500 K 2M 5M 52MA3B01 52MA3B04 52MA3B06 52MA3B08 52MA3B10 52MA3B12 52MA3B14 52MA3B15 52MA3B16 52MA3B20 52MA3B24 52MA3B28 52MA3B31 2 Button maintained operator Button remains depressed when pushed Black/red less caps red green gray Pack $ Unit 164.00 164.00 164.00 164.00 164.00 164.00 164.00 164.00 164.00 164.00 164.00 164.00 164.00 1 52MA2A1A2 52MA2 69.00 66.00 1 52ABW22) 52ABW32) 52ABW62) 47.00 47.00 47.00 1 52ABT 47.00 1 52MA4G2 52MA4G3 52MA4G5 52MA4G9 52MA4GA 52MA4GB 52MA4GN 87.00 87.00 87.00 87.00 87.00 87.00 82.00 1 52NP02 52NP02E 2.40 10.70 1 1 CONTROL PRODUCTS 16 Wobble stick 2.5" operator For use with 52BAJ (NC) contact block List Price Maintained toggle operator Compact pilot lights - 11/16" mounting hole1) / 18 mm Transformer type - 120V with 6V 755 type lamp red green blue amber clear white less lens Pilot Devices Legend plate for compact pilot light (1 7/16" x 1 7/16") Blank (brushed aluminum) Custom engraved (brushed aluminum) 1) 11/16" mounting hole required 2) For use with 52BAJ (NC) contact block 16-200 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Complete Units Selection and ordering data Contact blocks Flush cap order no.1) Extended cap order no.1) List Price Mushroom head List order no.1) Price $ Unit Pushbutton unit with assembled contact blocks black red green yellow 1 NO 1 NO 1 NO 1 NO 52PX8A1K 52PX8A2K 52PX8A3K 52PX8A4K 52PX8B1K 52PX8B2K 52PX8B3K 52PX8B4K 34.50 34.50 34.50 34.50 52PX9 52PX9 52PX9 52PX9 1K 2K 3K 4K 59.00 59.00 59.00 59.00 1 blue gray orange 1 NO 1 NO 1 NO 52PX8A5K 52PX8A6K 52PX8A8K 52PX8B5K 52PX8B6K 52PX8B8K 34.50 34.50 34.50 52PX9 5K 52PX9 6K 52PX9 8K 59.00 59.00 59.00 1 black red green yellow 1 NC 1 NC 1 NC 1 NC 52PX8A1J 52PX8A2J 52PX8A3J 52PX8A4J 52PX8B1J 52PX8B2J 52PX8B3J 52PX8B4J 34.50 34.50 34.50 34.50 52PX9 52PX9 52PX9 52PX9 1J 2J 3J 4J 59.00 59.00 59.00 59.00 1 blue gray orange 1 NC 1 NC 1 NC 52PX8A5J 52PX8A6J 52PX8A8J 52PX8B5J 52PX8B6J 52PX8B8J 34.50 34.50 34.50 52PX9 5J 52PX9 6J 52PX9 8J 59.00 59.00 59.00 1 black red green yellow 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 52PX8A1A 52PX8A2A 52PX8A3A 52PX8A4A 52PX8B1A 52PX8B2A 52PX8B3A 52PX8B4A 47.00 47.00 47.00 47.00 52PX9 52PX9 52PX9 52PX9 1A 2A 3A 4A 71.00 71.00 71.00 71.00 1 blue gray orange 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 52PX8A5A 52PX8A6A 52PX8A8A 52PX8B5A 52PX8B6A 52PX8B8A 47.00 47.00 47.00 52PX9 5A 52PX9 6A 52PX9 8A 71.00 71.00 71.00 1 black red green yellow 2 NO 2 NO 2 NO 2 NO 52PX8A1F 52PX8A2F 52PX8A3F 52PX8A4F 52PX8B1F 52PX8B2F 52PX8B3F 52PX8B4F 47.00 47.00 47.00 47.00 52PX9 52PX9 52PX9 52PX9 1F 2F 3F 4F 71.00 71.00 71.00 71.00 1 blue gray orange 2 NO 2 NO 2 NO 52PX8A5F 52PX8A6F 52PX8A8F 52PX8B5F 52PX8B6F 52PX8B8F 47.00 47.00 47.00 52PX9 5F 52PX9 6F 52PX9 8F 71.00 71.00 71.00 1 black red green yellow 2 NC 2 NC 2 NC 2 NC 52PX8A1G 52PX8A2G 52PX8A3G 52PX8A4G 52PX8B1G 52PX8B2G 52PX8B3G 52PX8B4G 47.00 47.00 47.00 47.00 52PX9 52PX9 52PX9 52PX9 1G 2G 3G 4G 71.00 71.00 71.00 71.00 1 blue gray orange 2 NC 2 NC 2 NC 52PX8A5G 52PX8A6G 52PX8A8G 52PX8B5G 52PX8B6G 52PX8B8G 47.00 47.00 47.00 52PX9 5G 52PX9 6G 52PX9 8G 71.00 71.00 71.00 1 black red green yellow 2 NO + 2 NC 2 NO + 2 NC 2 NO + 2 NC 2 NO + 2 NC 52PX8A1B 52PX8A2B 52PX8A3B 52PX8A4B 52PX8B1B 52PX8B2B 52PX8B3B 52PX8B4B 72.00 72.00 72.00 72.00 52PX9 52PX9 52PX9 52PX9 1B 2B 3B 4B 96.00 96.00 96.00 96.00 1 blue gray orange 2 NO + 2 NC 2 NO + 2 NC 2 NO + 2 NC 52PX8A5B 52PX8A6B 52PX8A8B 52PX8B5B 52PX8B6B 52PX8B8B 72.00 72.00 72.00 52PX9 5B 52PX9 6B 52PX9 8B 96.00 96.00 96.00 1 $ Flush assembled pushbutton Extended assembled pushbutton Mushroom head assembled pushbutton Order no. change Small operating head - 1 5/8" (41.3 mm) Large operating head - 2.5" (63.5 mm) Pack CONTROL PRODUCTS Color of actuator 16 Version D E Pilot Devices 1) For other contact block assemblies replace the 8th digit of the catalog number as follows: C = 3 NO + 3 NC D = 4 NO + 4 NC E = 1 NC (EB) H = 1 NO (EM) Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-201 Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Push Pull Operators Complete Units Selection and ordering data Version Color of actuator Contact blocks Order no. List Price Order no. $ List Price Pack $ Unit 2 Position Push Pull Maintained, Non Illuminated 2 position push-pull 2 position push pull illuminated CONTROL PRODUCTS 16 3 position push pull Small Plastic Mushroom Head, 1 5/8" (41.3 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2W1A 52PX2W2A 52PX2W3A 88.00 88.00 88.00 1 Large Plastic Mushroom Head, 2 1/2" (63.5 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2V1A 52PX2V2A 52PX2V3A 106.00 106.00 106.00 1 Small Plastic Mushroom Head, 1 5/8" (41.3 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX3W1U 52PX3W2U 52PX3W3U 96.00 96.00 96.00 1 Large Plastic Mushroom Head, 2 1/2" (63.5 mm) black red green 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX3V1U 52PX3V2U 52PX3V3U 104.00 104.00 104.00 1 less operating head chrome red chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO Operators with incandescent lamp 52PX2DNA 52PX2D2A 52PX2D3A 52PX2D9A 137.00 137.00 137.00 137.00 Operators with LED lamp 2) ***** 52PX2D2AY 52PX2D3AY 52PX2D9AY ––––– 1 151.00 151.00 151.00 full red full green full amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2DRA 52PX2DSA 52PX2DTA 137.00 52PX2DRAY 137.00 52PX2DSAY 173.00 52PX2DTAY 151.00 1 151.00 151.00 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2GNA 52PX2G2A 52PX2G3A 52PX2G9A 137.00 137.00 137.00 137.00 ***** 52PX2G2AY 52PX2G3AY 52PX2G9AY ––––– 1 151.00 151.00 151.00 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2GRA 52PX2GSA 52PX2GTA 137.00 52PX2GRAY 137.00 52PX2GSAY 137.00 52PX2GTAY 151.00 1 151.00 151.00 240V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2HNA 52PX2H2A 52PX2H3A 52PX2H9A 119.00 137.00 137.00 137.00 ***** 52PX2H2AY 52PX2H3AY 52PX2H9AY ––––– 151.00 1 151.00 151.00 480V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2JNA 52PX2J2A 52PX2J3A 52PX2J9A 119.00 137.00 137.00 137.00 ***** 52PX2J2AY 52PX2J3AY 52PX2J9AY ––––– 1 151.00 151.00 151.00 600V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX2KNA 52PX2K2A 52PX2K3A 52PX2K9A 119.00 137.00 137.00 137.00 ***** 52PX2K2AY 52PX2K3AY 52PX2K9AY ––––– 1 151.00 151.00 151.00 3 Position Push Pull Momentary, Non-Illuminated, spring return to center-pull to start, push to stop1) 2 Position Push Pull Maintained, Illuminated 24V Full Voltage with 757 type arge Plastic Mushroom Head, or 24V LED, 1 3/4" (44.5 mm) 120V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber Pilot Devices full red full green full amber 1) Blocks cannot be interchanged (start-stop circuit). 2) LED color must match lens color. 16-202 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Push Pull Operators Selection and ordering data Version Color of actuator** Contacts Order # List Operators with Price incandescent $ lamp Order # List Operators with Price 2 $ LED lamp ) Pack Unit 3 Position Push Pull Momentary, Illuminated, spring return to center1) 3 position push pull illuminated 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PX3DNU 52PX3D2U 52PX3D3U 52PX3D9U 52PX3DRU 52PX3DSU 52PX3DTU 119.00 137.00 137.00 137.00 119.00 119.00 119.00 ***** 52PX3D2UY 52PX3D3UY 52PX3D9UY 52PX3DRUY 52PX3DSUY 52PX3DTUY ––––– 1 151.00 151.00 151.00 151.00 1 151.00 151.00 120V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber full red full green full amber 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PX3GNU 52PX3G2U 52PX3G3U 52PX3G9U 52PX3GRU 52PX3GSU 52PX3GTU 119.00 137.00 137.00 137.00 119.00 119.00 119.00 ***** 52PX3G2UY 52PX3G3UY 52PX3G9UY 52PX3GRUY 52PX3GSUY 52PX3GTUY ––––– 1 151.00 151.00 151.00 151.00 1 151.00 151.00 240V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1NC + 1NO 1NC + 1NO 1NC + 1NO 1NC + 1NO 52PX3HNU 52PX3H2U 52PX3H3U 52PX3H9U 119.00 137.00 137.00 137.00 ***** 52PX3H2UY 52PX3H3UY 52PX3H9UY ––––– 151.00 1 151.00 151.00 480V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX3JNU 52PX3J2U 52PX3J3U 52PX3J9U 119.00 137.00 137.00 137.00 ***** 52PX3J2UY 52PX3J3UY 52PX3J9UY ––––– 1 151.00 151.00 151.00 600V transformer with 6V 755 type less operating head lamp, or 6V LED chrome red 1 3/4" (44.5 mm) chrome green chrome amber 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX3KNU 52PX3K2U 52PX3K3U 52PX3K9U 119.00 137.00 137.00 137.00 ***** 52PX3K2UY 52PX3K3UY 52PX3K9UY ––––– 1 151.00 151.00 151.00 16 less operating head chrome red chrome green chrome amber full red full green full amber 24V Full Voltage with 757 type, or 24V LED 1 3/4" (44.5 mm) CONTROL PRODUCTS Pilot Devices 1) Blocks cannot be interchanged (start-stop circuit). 2) LED color must match lens color. Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-203 Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Selector Switch Complete Units Selection and ordering data Version Lever type Contact blocks Cam1) Order no. List Price Pack $ unit Selector Switches with 2 switching positions Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated 1 NO 1 NC 1 NO + 1 NC A A A 52SX2AABK1 52SX2AABJ1 52SX2AABA1 42.50 1 42.50 55.00 Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1 NO 1 NC 1 NO + 1NC A A A 52SW2AABK1 52SW2AABJ1 52SW2AABA1 42.50 1 42.50 55.00 Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated 1 NO 1 NC 1 NO + 1 NC A A A 52SX2ACBK1 52SX2ACBJ1 52SX2ACBA1 59.00 1 59.00 72.00 Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1 NO 1 NC 1 NO + 1NC A A A 52SW2ACBK1 52SW2ACBJ1 52SW2ACBA1 59.00 1 59.00 72.00 Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SX2CABA1 52SX2GABJ2K1 52SX2CABA2 55.00 1 67.00 80.00 Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SW2CABA1 52SW2GABJ2K1 52SW2CABA2 55.00 1 67.00 80.00 Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SX2CCBA1 52SX2GCBJ2K1 52SX2CCBA2 72.00 1 84.00 96.00 Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SW2CCBA1 52SW2GCBJ2K1 52SW2CCBA2 72.00 1 84.00 96.00 Spring return from right & left operation Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SX2CDBA1 52SX2GDBJ2K1 52SX2CDBA2 72.00 1 84.00 96.00 Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SW2CDBA1 52SW2GDBJ2K1 52SW2CDBA2 72.00 1 84.00 96.00 Short lever, non-Illuminated Short lever, non-Illuminated Short lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SX2CBBA1 52SX2GBBJ2K1 52SX2CBBA2 72.00 1 84.00 96.00 Long lever, non-Illuminated Long lever, non-Illuminated Long lever, non-Illuminated 1 NO + 1 NC 2 NC + 1 NO 2 NO + 2 NC C G C 52SW2CBBA1 52SW2GBBJ2K1 52SW2CBBA2 72.00 1 84.00 96.00 Maintained operation Short lever assembled selector switch Long lever assembled selector switch Spring return from right operation Selector Switches with 3 switching positions Maintained operation CONTROL PRODUCTS 16 Spring return from right Pilot Devices Spring return from left 1) For contact operation, see cam selection table on page 16-209. 16-204 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Indicator Light Operators Selection and ordering data Version Color of actuator Order no. List Price Order no. List Price Pack Operators with Incandescent lamp $ Operators with LED lamp 3) $ red green amber less lens red green amber less lens red green amber less lens red green amber less lens 52PX4B2 52PX4B3 52PX4B9 52PX4BN 52PX4C2 52PX4C3 52PX4C9 52PX4CN 52PX4D2 52PX4D3 52PX4D9 52PX4DN 52PY4E2 52PY4E3 52PY4E9 52PY4EN 72.00 72.00 72.00 66.00 72.00 72.00 72.00 66.00 72.00 72.00 72.00 66.00 72.00 72.00 72.00 66.00 52PX4B2Y 52PX4B3Y 52PX4B9Y **** 86.00 1 86.00 86.00 ––––– 1 52PX4D2Y 52PX4D3Y 52PX4D9Y **** 52PX4E2Y 52PX4E3Y 52PX4E9Y **** 86.00 1 86.00 86.00 ––––– 86.00 1 86.00 86.00 ––––– red green amber less lens red green amber less lens red green amber less lens red green amber less lens red green amber less lens 52PX4G2 52PX4G3 52PX4G9 52PX4GN 52PX4H2 52PX4H3 52PX4H9 52PX4HN 52PX4T2 52PX4T3 52PX4T9 52PX4TN 52PX4J2 52PX4J3 52PX4J9 52PX4JN 52PX4K2 52PX4K3 52PX4K9 52PX4KN 88.00 88.00 88.00 82.00 88.00 88.00 88.00 82.00 88.00 88.00 88.00 82.00 88.00 88.00 88.00 82.00 88.00 88.00 88.00 82.00 52PX4G2Y 52PX4G3Y 52PX4G9Y **** 52PX4H2Y 52PX4H3Y 52PX4H9Y **** 52PX4J2Y 52PX4J3Y 52PX4J9Y **** 52PX4K2Y 52PX4K3Y 52PX4K9Y **** 52PX4T2Y 52PX4T3Y 52PX4T9Y **** 102.00 102.00 102.00 ––––– 102.00 102.00 102.00 ––––– 102.00 102.00 102.00 ––––– 102.00 102.00 102.00 ––––– 102.00 102.00 102.00 ––––– 240V with 120V 2.5W 120MB type lamp,or 120V LED red green amber less lens 52PY4N2 52PY4N3 52PY4N9 52PY4NN 72.00 72.00 72.00 66.00 52PX4N2Y 52PX4N3Y 52PX4N9Y **** 86.00 1 86.00 86.00 ––––– Color code table blue clear white Unit Indicator light with plastic lens Full voltage type AC/DC1)2) Indicator light 6-8V with 755 type, or 6V LED 12V with 756 type 24V with 757 type, or 24V LED 120V with 120MBtype, or 120V LED Indicator light with plastic lens Transformer type AC/DC1)2) 120V with 6V 755 type lamp, or 6V LED 240V with 6V 755 type lamp, or 6V LED 600V with 6V 755 type lamp, or 6V LED 1 CONTROL PRODUCTS 480V with 6V 755 type lamp, or 6V LED 1 16 277V with 6V 755 type lamp, or 6V LED 1 1 1 Indicator light with plastic lens Resistor type AC/DC * 5 A B 5 A B Pilot Devices 1) All illuminated devices come with std. Touch-safe shield per UL stds. 2) For factory installed glass lens, replace the 5th character with "5". Discount Schedule PILO 3) LED color must match lens color. Consult Factory for Neon types. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-205 Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Push to Test Units Selection and ordering data Version Color of actuator Contact blocks Order no. List Price Operators with Incandescent lamp3) Push to test/illuminated pushbutton $ Order no. List Price Pack Operators with LED lamp 2)3) $ Unit Illuminated pushbutton/Push to test indicator plastic lens - Full indicator light with plastic lens - Full voltage type AC/DC1) 6-8V with 755 type, or 6V LED red green amber less lens 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 52PX6B2A 52PX6B3A 52PX6B9A 52PX6BNA 96.00 96.00 96.00 91.00 52PX6B2AY 52PX6B3AY 52PX6B9AY **** 110.00 1 110.00 110.00 ––––– 24V with 757 type, or 24V LED red green amber less lens 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 52PX6D2A 52PX6D3A 52PX6D9A 52PX6DNA 96.00 96.00 96.00 91.00 52PX6D2AY 52PX6D3AY 52PX6D9AY ***** 110.00 1 110.00 110.00 ––––– red green amber less lens red green amber less lens red green amber less lens red green amber less lens 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX6G2A 52PX6G3A 52PX6G9A 52PX6GNA 52PX6H2A 52PX6H3A 52PX6H9A 52PX6HNA 52PX6J2A 52PX6J3A 52PX6J9A 52PX6JNA 52PX6K2A 52PX6K3A 52PX6K9A 52PX6KNA 112.00 112.00 112.00 107.00 112.00 112.00 112.00 112.00 112.00 112.00 112.00 107.00 112.00 112.00 112.00 107.00 52PX6G2AY 52PX6G3AY 52PX6G9AY ***** 52PX6H2AY 52PX6H3AY 52PX6H9AY ***** 52PX6J2AY 52PX6J3AY 52PX6J9AY ***** 52PX6K2AY 52PX6K3AY 52PX6K9AY ***** 126.00 126.00 126.00 ––––– 126.00 126.00 126.00 ––––– 126.00 126.00 126.00 ––––– 126.00 126.00 126.00 ––––– 120V with 24V 757 type lamp, or 24V LED red green amber less lens 240V with 24V 757 type lamp, or 24V LED red green amber less lens 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO 52PX6M2A 52PX6M3A 52PX6M9A 52PX6MNA 52PX6N2A 52PX6N3A 52PX6N9A 52PX6NNA 96.00 96.00 96.00 96.00 96.00 96.00 96.00 91.00 52PX6M2AY 52PX6M3AY 52PX6M9AY ***** 52PX6N2AY 52PX6N3AY 52PX6N9AY **** 110.00 1 110.00 110.00 ––––– 110.00 1 110.00 110.00 ––––– Illuminated pushbutton/Push to test plastic lens indicator light with plastic lens - Transformer type AC/DC1) 120V with 6V 755 type lamp, or 6V LED 240V with 6V 755 type lamp, or 6V LED 480V with 6V 755 type lamp, or 6V LED CONTROL PRODUCTS 16 600V with 6V 755 type lamp, or 6V LED 1 1 1 1 Illuminated pushbutton/Push to test indicator indicator light with plastic lens - Resistor type AC/DC Color code table bl u e clear white 5 A B 5 A B Wiring Diagrams Push to Test Pilot Devices Illuminated push button 1) All illuminated devices come with std. Touch-safe shield per UL stds. 2) LED color must match lens color. Consult Factory for Neon types. 16-206 3) For factory installed lens guard add suffix "Y". Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Push to Test Units Selection and ordering data Flush pushbutton operator Extended pushbutton operator Mushroom head pushbutton operator Version Color of actuator Order no. Pushbutton with flush cap black red green yellow 52PX8A1 52PX8A2 52PX8A3 52PX8A4 22.00 22.00 22.00 22.00 blue gray orange less cap kit - with all colors 52PX8A5 52PX8A6 52PX8A8 52PX8 52PX8AN 22.00 22.00 22.00 20.50 25.50 black red green yellow 52PX8B1 52PX8B2 52PX8B3 52PX8B4 22.00 22.00 22.00 22.00 blue gray orange less cap kit - with all colors 52PX8B5 52PX8B6 52PX8B8 52PX8 52PX8BN 22.00 22.00 22.00 20.50 25.50 black red green yellow 52PX9D1 52PX9D2 52PX9D3 52PX9D4 46.50 46.50 46.50 46.50 blue gray orange less cap kit - with all colors 52PX9D5 52PX9D6 52PX9D8 52PX9 52PX9DN 46.50 46.50 46.50 38.50 49.00 black re d green yellow 52PX9E1 52PX9E2 52PX9E3 52PX9E4 55.00 55.00 55.00 55.00 blue gray orange less cap kit - with all colors 52PX9E5 52PX9E6 52PX9E8 52PX9 52PX9EN 55.00 55.00 55.00 38.50 49.00 black red green 52PX2W1 52PX2W2 52PX2W3 63.00 63.00 63.00 1 black red green 52PX2V1 52PX2V2 52PX2V3 82.00 82.00 82.00 1 Pushbutton with extended cap Pushbutton with mushroom cap 1 5/ 8" ( 41 . 3 mm ) Large Plastic Mushroom Head, 2 1/4" (57.2mm) $ Unit 1 1 1 CONTROL PRODUCTS 2 position push pull maintained, non illuminated Small Plastic Mushroom Head, 1 5/8" (41.3mm) Pack 16 Pushbutton with mushroom cap 2 1/ 2" ( 63 . 5 mm ) List Price 1 Pilot Devices Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-207 Pushbutton Units and Indicator Lights 30 mm, Black Max Corrosion Resistant, Class 52 Selector Switch Operators Selection and ordering data Version Lever type Color of Cam1) Order no. lever insert List Price Pack $ unit Selector Switches with 2 switching positions Maintained operation Short lever, non-Illuminated Long lever, non-Illuminated white white A A 52SX2AAB 52SW2AAB 30.50 1 30.50 Spring return from right operation Short lever, non-Illuminated Long lever, non-Illuminated white white A A 52SX2ACB 52SW2ACB 47.00 1 47.00 Maintained operation Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated white white white white white white white white white white B B C2) C2) D D E E G G 52SX2BAB 52SW2BAB 52SX2CAB 52SW2CAB 52SX2DAB 52SW2DAB 52SX2EAB 52SW2EAB 52SX2GAB 52SW2GAB 30.50 1 30.50 30.50 30.50 30.50 30.50 30.50 30.50 30.50 30.50 Spring return from right operation Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated white white white white white white white white white white B B C2) C2) D D E E G G 52SX2BCB 52SW2BCB 52SX2CCB 52SW2CCB 52SX2DCB 52SW2DCB 52SX2ECB 52SW2ECB 52SX2GCB 52SW2GCB 47.00 1 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 Spring return from left operation Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated white white white white white white white white white white B B C2) C2) D D E E G G 52SX2BBB 52SW2BBB 52SX2CBB 52SW2CBB 52SX2DBB 52SW2DBB 52SX2EBB 52SW2EBB 52SX2GBB 52SW2GBB 47.00 1 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 Spring return from left and right operation Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated Short lever, non-Illuminated Long lever, non-Illuminated white white white white white white white white white white B B C2) C2) D D E E G G 52SX2BDB 52SW2BDB 52SX2CDB 52SW2CDB 52SX2DDB 52SW2DDB 52SX2EDB 52SW2EDB 52SX2GDB 52SW2GDB 47.00 1 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 47.00 white white H H 52SX2HAB 52SW2HAB 30.50 1 30.50 CONTROL PRODUCTS 16 Selector Switches with 3 switching positions Selector Switches with 4 switching positions Pilot Devices Maintained operation Non-Illuminated, Short lever Non-Illuminated, Long lever 1) For contact operation, see cam selection table on page 16/209. 2) C- Cam is limited to 4 contact blocks, 1 or 2 pole, SR only. 16-208 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Cam Selection Selection and ordering data Ordering Information • Contact blocks are ordered separately, see page 16-213. • Under Selector Position find the selector operation required (2 or 3 position). • Select the contact operation required for each selector lever position (X indicates when contacts areclosed). • The cam letter column identifies the cam of the selector operator. • Contact block must be assembled in position shown for each circuit application. • Cam D, E or G may be ordered at the same price by changing the 6th character of the selector catalog number. Example: Selector with D cam 51SA2DA. • C Cam on spring return selectors is limited to 4 contact blocks. • Selector operators in enclosures are limited to depth of 1 contact block. (2 blocks wide). Cam Contact block letter catalog no. Lever or key operators (viewed from front) Selector position Lever position (X indicates contact closed) 2 X O Illuminated X O Left Right Left 3 A 52BAJ (NC) 52BAK (NO) L L O X A 52BAJ (NC) 52BAK (NO) L L B 52BAK (NO) 52BAK (NO) 52BAJ (NC) 52BAJ (NC) 2 - 52BAK* (NO) 52BAJ (NC) 52BAK (NO) 52BAJ (NC) 52BAK (NO) 52BAK (NO) 52BAJ (NC) 52BAJ (NC) 52BAJ (NC) 52BAK (NO) Center Right O O X X O O O X O O X O X O O X O X X O X O X O O O O X O O X O O X O X R R Right C D E G C B Left center Right center X O O O Right or or 52BAJ (NC) 52BAK (NO) 52BAK (NO) 52BAJ (NC) R L L L L L L L L L L and or or or or or or R R R R R R R R L or R R CONTROL PRODUCTS Left 4 Left O X 16 X O X O X X O O O X O X O O Illuminated X O O O Mounting (viewed from front) L L R R Right O X O O O O X O O O O X Left N D N Right D X X O O X O X X O O O X X O O X X O X O O O O O O X X X O O O O X X O X O X O X H 52BAK (NO) 52BAJ (NC) 52BAJ (NC) 52BAK (NO) R L R L Selector pushbutton operators 2 3 Center P R 52BAK (NO) 52BAJ (NC) 52BAJ (NC) 52BAK (NO) R L R L L L L or or R R Pilot Devices Left Q R R L Right N D N D N D X X O O X O X O O X O O O X O X O O O O O O X X L R R S L Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-209 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Custom Selector Switch Designs Selection and ordering data Assembled Non-illuminated Selector Switches • Determine contact block and location from above. • Additional suffixes allow for multiple quantities and locations. • Select block suffix. Ex: J = 52BAJ. • Repeat process for next block if required. • Now select position suffix. • Add list price of blocks to operator list price. • 1-52BAJ block mounted on right side, suffix will be J 1. • Consult factory for delivery. X O O O O X HAND-OFF-AUTO Maintained Switch Catalog No 52SA2CAB A 1 = 52A2CABA1 (52BJK block mounted on right side) Example 1: Block Suffix Position Suffix Example 2: A = 1 NO - 1 NC, 52BJK E = NC Late Break, 52BAE H = NO Early Make, 52BAH J = NC, 52BAJ K = NO, 52BAK Suffix 0 1 2 3 4 5 6 7 8 9 X O O O X O O O X } J2 K1 = 52SA2GABJ2K1 Pilot Devices CONTROL PRODUCTS 16 G Cam required Catalog No 52SA2GAB 52BAJ (L) J2 52BAJ (R) 52BAK (L or R) } K1 16-210 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Quantity and Location Left Right 1 — — 1 1 1 2 — — 2 2 1 1 2 2 2 3 — — 3 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Accessories and Spare Parts Selection and ordering data Version Suitable for Flush actuator button Order no. For flush type, non-illuminated pushbuttons black red green yellow blue gray orange kit- all colors 52RA1A1 52RA1A2 52RA1A3 52RA1A4 52RA1A5 52RA1A6 52RA1A8 52RA1AN 1.60 1.60 1.60 1.60 1.60 1.60 1.60 11.20 Extended actuator button For extended type, non-illuminated pushbuttons black red green yellow blue gray orange 1 of each color cap 52RA1B1 52RA1B2 52RA1B3 52RA1B4 52RA1B5 52RA1B6 52RA1B8 52RA1BN 1.60 1.60 1.60 1.60 1.60 1.60 1.60 11.20 Mushroom head - Plastic For small 1 5/8"(41.3mm) type, non-illuminated mushroom pushbuttons and push-pull; set screw black red green yellow blue gray orange 1 of each color cap 52RB3D1 52RB3D2 52RB3D3 52RB3D4 52RB3D5 52RB3D6 52RB3D8 52RB3DN 8.20 8.20 8.20 8.20 8.20 8.20 8.20 65.60 Mushroom head - Metal For small 1 5/8"(41.3mm) type, non-illuminated push-pull; set screw chrome red green 52RB3FC 52RB3F2 52RB3F3 17.80 17.80 17.80 Mushroom head - Plastic For large 2 1/2"(63.5mm) type, non-illuminated mushroom pushbuttons and push-pull; set screw black red green yellow blue gray orange 1 kit of each color cap 52RB3E1 52RB3E2 52RB3E3 52RB3E4 52RB3E5 52RB3E6 52RB3E8 52RB3EN 16.40 16.40 16.40 16.40 16.40 16.40 16.40 131.00 Illuminated mushroom head Illuminated metal For 1 3/4" illuminated mushroom head pushbuttons; threaded red green amber 52RB3H2 52RB3H3 52RB3H9 18.00 18.00 18.00 green red amber 52RB3JG 52RB3JR 52RB3JA 18.00 18.00 18.00 Replacement Lens for Pilot Lights Plastic lens red green blue amber clear white 52RA4P2 52RA4P3 52RA4P5 52RA4P9 52RA4PA 52RA4PB 5.80 5.80 5.80 5.80 5.80 5.80 Glass lens red green blue amber clear white 52RA4G2 52RA4G3 52RA4G5 52RA4G9 52RA4GA 52RA4GB 22.50 22.50 22.50 22.50 22.50 22.50 Replacement Lens for Push to test/Illuminated pushbuttons Plastic lens red green blue amber clear white 52RA5P2 52RA5P3 52RA5P5 52RA5P9 52RA5PA 52RA5PB 5.80 5.80 5.80 5.80 5.80 5.80 Pilot Devices Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog CONTROL PRODUCTS Discount Schedule PILO List Price $ 16 Color Illuminated plastic Lamp voltage 16-211 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Accessories and Spare Parts Selection and ordering data Version Suitable for Lamp Color voltage Order no. List Price $ Replacement lens kit for Illuminated selector switches Knob & Insert red green blue amber clear white 52RA6P2 52RA6P3 52RA6P5 52RA6P9 52RA6PA 52RA6PB 5.80 5.80 5.80 5.80 5.80 5.80 Lever inserts Short lever red green blue yellow gray orange white red green blue yellow gray orange white 52RA2A2 52RA2A3 52RA2A5 52RA2A4 52RA2A6 52RA2A8 52RA2AB 52RA2B2 52RA2B3 52RA2B5 52RA2B4 52RA2B6 52RA2B8 52RA2BB 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 red green blue amber clear white 52RA7P2 52RA7P3 52RA7P5 52RA7P9 52RA7PA 52RA7PB 5.80 5.80 5.80 5.80 5.80 5.80 Long lever CONTROL PRODUCTS 16 Replacement lens for compact style pilot lights Replacement lenses Clear protective boot Offers protection from ice and foreign substances from interfering with button operation Flush pushbutton operators 52AABA 16.40 Pushbutton guard Prevents accidental operation of the pushbutton Lens guard Non-Illuminated pushbuttons Black Max styles, non-Illuminated pushbuttons Push to test buttons and pilot lights 52AAGP 52AXGP 8.20 8.20 52AAGL 8.20 Black Max styles, push to test buttons and pilot lights 52AXGL 8.20 Guard for mushroom head Additional hole spacing is required on adjacent devices 1 5/8"(41.3mm) mushroom head pushbutton and push-pull operators Black Max styles,1 5/8"(41.3mm) mushroom head pushbutton and push-pull operators 52AAGM 33.00 52AXGM 33.00 Pushbutton locknut Replacement front ring Pushbutton and push-to-test device Black Max styles 52AANP 52AXNP 2.70 2.70 Push-pull/pilot light locknut Replacement front ring Selector switch locknut Replacement front ring Padlock attachments 52AANL 52AXNL 52AANS 52AXNS 52AALA 52AALB 52AALS 2.70 2.70 2.70 2.70 24.50 24.50 49.00 52AALE 47.00 Spare keys Grounding kit Touchsafe shield Mushroom head and pilot light indicators Black Max styles Selector switch Black Max styles, selector switch Flush pushbutton operators Extended operators1) Pushbuttons, selector switches, and nonilluminated mushroom heads Pushbuttons, selector switches, and illuminated mushroom heads All devices Corrosion resistant Steel, gray Stainless steel 501CH (1 key) All devices Illuminated devices (Current revisions only) 52MAWB 52AAH6 52ABH6 52ABHS D28671015 52AL109145 52AASH 24.50 8.20 8.20 24.50 5.60 4.20 2.40 Black boot Rubber gasket (5) Yellow 90 mm ESTOP ring Extended or flush pushbuttons All devices All E-Stops 52AAB1 52AAD 52AAR 16.40 2.40 4.50 Padlock cover Can be used to lock devices in the off position Pilot Devices Lock nut wrench Hole plugs 1) Must be used with step raised cap- 52PA8C2. 16-212 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Accessories and Spare Parts Selection and ordering data Version Suitable for Lamp voltage Color Order no. List Price $ Lamps with screw connection, miniature bayonet (BA 9s style) Incandescent lamps, Flashing, type 267 lamp (replaces 755 lamp) 51, 52 6V type 755 lamp 51, 52 12V type 756 51, 52 24V type 757 51, 52 120V, 2.5W, type #120MB 52 Neon (uses resistors) type B2A (NE-51H) 52 48V 51, 52 Candelabra, 120 V, Full voltage type 3S6/51) 7 Watts 52 older revision styles LED’s BA9s Style length 28 mm diameter 10 mm current 15 ma 1 NC extra late break 1 NO 1 NC 6 V UC 6 V UC 6 V UC 6 V UC 6 V UC red green yellow white blue 52AEB2 52AEB3 52AEB4 52AEBB 52AEB5 22.50 22.50 22.50 22.50 22.50 52 52 52 52 52 24 V UC 24 V UC 24 V UC 24 V UC 24 V UC red green yellow white blue 52AED2 52AED3 52AED4 52AEDB 52AED5 22.50 22.50 22.50 22.50 22.50 52 52 52 52 52 120 V AC 120 V AC 120 V AC 120 V AC 120 V AC red green yellow white blue 52AEE2 52AEE3 52AEE4 52AEEB 52AEE5 22.50 22.50 22.50 22.50 22.50 52 52 52 6 V UC 6 V UC 6 V UC red green yellow 52AEB27 52AEB37 52AEB47 28.00 28.00 28.00 52 52 52 24 V UC 24 V UC 24 V UC red green yellow 52AED27 52AED37 52AED47 28.00 28.00 28.00 52 52 52 120 V AC red 120 V AC green 120 V AC yellow 52AEE27 52AEE37 52AEE47 28.00 28.00 28.00 White Red Black Green Yellow ___ 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAR2) 12.40 12.40 24.50 12.40 12.40 49.50 Blue 52BAU 52BAKE 52BAJE 12.40 15.40 15.40 1) Design change made in 2003 from candelabra to BA 9s type bulbs. Contact technical support for further information. Discount Schedule PILO closes before 52BAK opens after 52 BAJ Reed switch UL listed for class 1 division 2 .25A Max, 200V AC, 10 Watt max .5A Max, 200V DC, 10 Watt max Not touch safe Not touch safe 8.20 Plunger Color Pilot Devices 52 BAR 52AAENC CONTROL PRODUCTS 52 BAK 1 NO 1 NC 1 NO - 1 NC 1 NO early make 1 NC late break 1 NO - 1 NC 120 V 12.40 8.20 8.20 7.50 8.20 16.90 12.50 52 52 52 52 52 Touchsafe contact blocks with gold flashing 52 BAJ 52AABNF 52AABN 52AACN 52AADN 52AAENC1 52AAPN 3SB1902-1AP 16 LED's, cluster type For use with Class 52 pilot lights only (7 LED’s) 6 V AC 6 V AC 12 V AC 24 V AC 120V AC 120 V AC 48 V 2) Hermetically sealed. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-213 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Dimensional Drawings Dimension drawings, inch (mm) Contact block Non-illuminated momentary pushbutton flush, extended, styles with one contact block 1.00 (25) 1.64 (42) .03 (1) Contact Block.eps file missing 1.05 (27) 2.11 (54) .39 (10) .39 (10) .39 (10) 2 position maintained non-illuminated 2 position maintained push-pull illuminated Small mushroom head momentary pushbutton 3 position maintained non-illuminated 3 position maintained push-pull illuminated Pilot Devices CONTROL PRODUCTS 16 Large mushroom head momentary pushbutton 16-214 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Dimensional Drawings Dimension drawings, inch (mm) Pilot light full voltage and transformer Push to test illuminated pushbutton Selector switches and keyed selector switches illuminated and non-illuminated Selector push operator 2 button maintained operator Maintained toggle operator 16 CONTROL PRODUCTS Pilot Devices Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-215 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Class 52 Oiltight Pushbutton Station Selection and ordering data Actuator identification C = top device in station B = middle device in station A = bottom device in station Degree of protection Contact / voltage No. of Order no. List command Price points A = Momentary flush pushbutton black, label "START" NEMA 12 1NO - 1NC 1 52C101A 131.00 $ NEMA 12 1NO - 1NC 1 52C103A 131.00 A = Momentary mushroom head red, label "STOP" NEMA 12 1NO - 1NC 1 52C104A 155.00 A = Maintained metal mushroom head red, label "EMERGENCY STOP" NEMA 12 1NO - 1NC 1 52C117A 183.00 A = 2 position selector switch "OFF-ON" NEMA 12 1NO - 1NC 1 52C159A 140.00 A = 3 position selector switch "HAND-OFF-AUTO" NEMA 12 1NO - 1NC 1 52C156A 140.00 A = Indicator light, red NE M A 1 2 120V Transformer type 1 52C131A 155.00 A = Indicator light, green NE M A 1 2 120V Transformer type 1 52C135A 155.00 A = Momentary flush pushbutton black, label "START" NEMA 4X Stainless Steel 1NO - 1NC 1 52C101S 209.00 A = Momentary raised pushbutton red, label "STOP" NEMA 4X Stainless Steel 1NO - 1NC 1 52C103S 209.00 A = Momentary mushroom head red, label "STOP" NEMA 4X Stainless Steel 1NO - 1NC 1 52C104S 233.00 A = Maintained metal mushroom head red, label "EMERGENCY STOP" (metal head) NEMA 4X Stainless Steel 1NO - 1NC 1 52C116S 249.00 A = 2 position selector switch "OFF-ON" NEMA 4X Stainless Steel 1NO - 1NC 1 52C159S 216.00 A = 3 position selector switch "HAND-OFF-AUTO" NEMA 4X Stainless Steel 1NO - 1NC 1 52C156S 216.00 A = Momentary flush pushbutton black, label "START" NEMA 4X Fiberglass 1NO - 1NC 1 52C101X 159.00 A = Momentary raised pushbutton red, label "STOP" NEMA 4X Fiberglass 1NO - 1NC 1 52C103X 159.00 A = Momentary mushroom head red, label "STOP" NEMA 4X Fiberglass 1NO - 1NC 1 52C104X 183.00 A = Maintained metal mushroom head red, label "EMERGENCY STOP" (metal head) NEMA 4X Fiberglass 1NO - 1NC 1 52C116X 199.00 A = 2 position selector switch "OFF-ON" NEMA 4X Fiberglass 1NO - 1NC 1 52C159X 166.00 A = 3 position selector switch "HAND-OFF-AUTO" NEMA 4X Fiberglass 1NO - 1NC 1 52C156X 166.00 B = Momentary flush pushbutton black, label "START" 2 unit control A = Momentary raised pushbutton red, label "STOP" NEMA 12 1NO, 1NC 1NO, 1NC 2 52C201A 189.00 B = Momentary flush pushbutton green, label "START" A = Momentary Mushroom head pushbutton red, label "STOP" NEMA 12 1NO, 1NC 1NO, 1NC 2 52C202A 213.00 B = Momentary flush pushbutton, label "FORWARD" A = Momentary flush pushbutton, label "REVERSE" NEMA 12 1NO, 1NC 1NO, 1NC 2 52C204A 189.00 B = Momentary flush pushbutton, label "UP" A = Momentary flush pushbutton, label "DOWN" NEMA 12 1NO, 1NC 1NO, 1NC 2 52C223A 200.00 B = Indicator light, red, label "RUN" A = Maintained selector switch, label "HAND-OFF-AUTO" NEMA 12 120V Transformer type 2 52C224A 249.00 B = Indicator light, red A = Indicator light, green NEMA 12 120V Transformer type 2 52C230A 255.00 B = Momentary flush pushbutton black, label "START" A = Momentary raised pushbutton red, label "STOP" NEMA 4X Stainless Steel 1NO, 1NC 1NO, 1NC 2 52C201S 265.00 B = Momentary flush pushbutton green, label "START" A = Momentary Mushroom head pushbutton red, label "STOP" NEMA 4X Stainless Steel 1NO, 1NC 1NO, 1NC 2 52C202S 290.00 B = Momentary flush pushbutton, label "UP" A = Momentary flush pushbutton, label "DOWN" NEMA 4X Stainless Steel 1NO, 1NC 1NO, 1NC 2 52C223S 265.00 B = Indicator light, red, label "RUN" NEMA 4X Stainless Steel 120V Transformer A = Maintained selector switch, label "HAND-OFF-AUTO" type 1NO, 1NC 2 52C224S 314.00 B = Momentary flush pushbutton black, label "START" A = Momentary raised pushbutton red, label "STOP" NEMA 4X Fiberglass 1NO, 1NC 1NO, 1NC 2 52C201X 225.00 B = Momentary flush pushbutton green, label "START" A = Momentary Mushroom head pushbutton red, label "STOP" NEMA 4X Fiberglass 1NO, 1NC 1NO, 1NC 2 52C202X 249.00 B = Momentary flush pushbutton, label "UP" A = Momentary flush pushbutton, label "DOWN" NEMA 4X Fiberglass 1NO, 1NC 1NO, 1NC 2 52C223X 225.00 120V Transformer type 1NO, 1NC 2 52C224X 274.00 station Pilot Devices CONTROL PRODUCTS 16 1 unit control A = Momentary raised pushbutton red, label "STOP" station B = Indicator light, red, label "RUN" NEMA 4X Fiberglass A = Maintained selector switch, label "HAND-OFF-AUTO" 16-216 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Pack Unit Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Class 52 Oiltight Pushbutton Station Selection and ordering data Contact / voltage No. of Order no. List command Price points C = Indicator light, red NEMA 12 3 52C307A 279.00 B = Momentary flush pushbutton black, label "START" A = Momentary raised pushbutton red, label "STOP" 120V 1NO, 1NC 1NO, 1NC 1NO, 1NC C = Momentary flush pushbutton black, label "FORWARD" NEMA 12 B = Momentary flush pushbutton black, label "REVERSE" A = Momentary raised pushbutton red, label "STOP" 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C301A 255.00 C = Momentary flush pushbutton black, label "UP" B = Momentary flush pushbutton black, label "DOWN" A = Momentary raised pushbutton red, label "STOP" NEMA 12 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C332A 265.00 C = Momentary flush pushbutton black, label "OPEN" B = Momentary flush pushbutton black, label "STOP" A = Momentary raised pushbutton red, label "CLOSE" NEMA 12 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C333A 265.00 C = Momentary flush pushbutton black, label "HI" B = Momentary flush pushbutton, black label "LOW" A = Momentary raised pushbutton red, label "STOP" NEMA 12 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C334A 265.00 C = Indicator light, red NEMA 4X Stainless Steel 120V 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C307S 413.00 C = Momentary flush pushbutton black, label "FORWARD" NEMA 4X Stainless Steel 1NO, 1NC B = Momentary flush pushbutton black, label "REVERSE" 1NO, 1NC A = Momentary raised pushbutton red, label "STOP" 1NO, 1NC 3 52C301S 372.00 C = Momentary flush pushbutton black, label "UP" B = Momentary flush pushbutton black, label "DOWN" A = Momentary raised pushbutton red, label "STOP" NEMA 4X Stainless Steel 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C332S 372.00 C = Momentary flush pushbutton black, label "OPEN" B = Momentary flush pushbutton black, label "STOP" A = Momentary raised pushbutton red, label "CLOSE" NEMA 4X Stainless Steel 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C333S 372.00 C = Momentary flush pushbutton black, label "HI" B = Momentary flush pushbutton, black label "LOW" A = Momentary raised pushbutton red, label "STOP" NEMA 4X Stainless Steel 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C334S 372.00 C = Indicator light, red B = Momentary flush pushbutton black, label "START" A = Momentary raised pushbutton red, label "STOP" NEMA 4X Fiberglass 120V 1NO, 1NC 1NO, 1NC 3 52C307X 331.00 C = Momentary flush pushbutton black, label "FORWARD" NEMA 4X Fiberglass B = Momentary flush pushbutton black, label "REVERSE" A = Momentary raised pushbutton red, label "STOP" 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C301X 290.00 C = Momentary flush pushbutton black, label "UP" B = Momentary flush pushbutton black, label "DOWN" A = Momentary raised pushbutton red, label "STOP" NEMA 4X Fiberglass 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C332X 290.00 C = Momentary flush pushbutton black, label "OPEN" B = Momentary flush pushbutton black, label "STOP" A = Momentary raised pushbutton red, label "CLOSE" NEMA 4X Fiberglass 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C333X 290.00 C = Momentary flush pushbutton black, label "HI" B = Momentary flush pushbutton, black label "LOW" A = Momentary raised pushbutton red, label "STOP" NEMA 4X Fiberglass 1NO, 1NC 1NO, 1NC 1NO, 1NC 3 52C334X 290.00 $ 3 unit control station B = Momentary flush pushbutton black, label "START" A = Momentary raised pushbutton red, label "STOP" Pack Unit CONTROL PRODUCTS Degree of protection 16 Actuator identification Pilot Devices Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-217 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Empty Enclosures Selection and ordering data Version Nu m b e r o f command points Degree of protection Order No. Standard enclosures come with 2 1/4" leg center for legend spacing. Automotive end plates require 2 1/2 " spacing. For more than 2 contact blocks on the right or left, use extra deep enclosure. 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 6 6 6 9 9 9 12 12 12 16 16 16 NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel NEMA Type 4/4X Fiberglass NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel NEMA Type 4/4X Fiberglass NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel NEMA Type 4/4X Fiberglass NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel NEMA Type 4/4X Fiberglass NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel NEMA Type 12/13 NEMA Type 12/13 extra deep NEMA Type 4/4X stainless steel P30EMS01 P30EMS01D P30EMS014 P30EMS01X P30EMS02 P30EMS02D P30EMS024 P30EMS02X P30EMS03 P30EMS03D P30EMS034 P30EMS03X P30EMS04 P30EMS04D P30EMS044 P30EMS04X P30EMS06 P30EMS06D P30EMS064 P30EMS09 P30EMS09D P30EMS094 P30EMS12 P30EMS12D P30EMS124 P30EMS16 P30EMS16D P30EMS164 Mounting hole arrangement 1 thu 4 are in one row 6 holes are 3 down and 2 across 9 holes are 3 down and 3 across 12 holes are 4 down and 3 across 16 holes are 4 down and 4 across List Price Pack $ Unit 82.00 82.00 148.00 98.00 91.00 102.00 155.00 115.00 107.00 102.00 213.00 131.00 131.00 149.00 279.00 153.00 165.00 189.00 410.00 215.00 243.00 509.00 289.00 328.00 616.00 371.00 421.00 812.00 CONTROL PRODUCTS 16 Order Form Ordering Information A B C D 1 2 Order No./Item No. • Select enclosure 3 4 Enclosure Hole Arrangement • Vertical or Horizontal. Outline Diagram at left starting at the top left-hand corner. Example: 3 unit vertical outline location No. 1A, 2A and 3A. 3 unit horizontal outline location No. 1A, 1B, and 1C Customer • List location No. and applicable catalog numbers in the table below. Use complete catalog numbers where possible Enclosure Catalog No. Operator PB-SEL.-PL Accessories Key Lock, Boot, Etc, Legend Plate Legend or Blank Special Marking Pilot Devices Location To order non-standard control stations select catalog numbers from the previous pages, determine the required position in the enclosure and fill in the table below. If a special legend plate is required, specify description in the table. The combined list prices of the components is the list price of the station. 16-218 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Discount Schedule PILO Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Legend Plates for Class 51 & 52 Design The 30 mm legend plates are approved for the use with both Class 51 and Class 52 devices. Automotive legend plates require 2 1/2" mounting centers. Plastic legend plates will have white letters ingraved. When ordering custom engraved legend plates, specify the required inscription text. See page 16-218. Selection and ordering data Inscription 2 1 1/4 2 1 5/8 2 7/16 Large List Automotive1) List Large Plastic2) List Automotive Plastic1)2) List (1 7/16" x 2") Price (2 7/16" x 2 7/16") Price (1 7/16" x 2") Price (2 7/16" x 2 7/16") Price Order No. $ Order No. $ Order No. $ Order No. $ — 52ND02R 52ND02B –––– 2.40 2.40 — 52NE02R 52NE02B –––– 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– –––– CONTROL PRODUCTS 4.20 4.20 4.20 16 52NL02 2.40 52NA02 "Blank (brushed aluminum)" "Blank (red)" 52NL02R 2.40 52NA02R "Blank (Black)" 52NL02B 2.40 52NA02B Inscribed legend plates with large brushed aluminum background Close 52NL18 2.40 52NA18 Down 52NL10 2.40 52NA10 Emerg Stop 52NL16 2.40 52NA16 Emerg Stop (red) 52NL16R 2.40 52NA16R Fast-Slow 52NL33 2.40 52NA33 Forward 52NL05 2.40 52NA05 For-Off-Rev 52NL38 2.40 52NA38 For-Rev 52NL31 2.40 52NA31 Hand-Off-Auto 52NL37 2.40 52NA37 High 52NL07 2.40 52NA07 High-Low 52NL30 2.40 52NA30 52NL44 2.40 52NA44 High-Off-Low In 52NL21 2.40 52NA21 Jog 52NL13 2.40 52NA13 Jog-Forward 52NL24 2.40 52NA24 Jog-Reverse 52NL25 2.40 52NA25 52NL08 2.40 52NA08 Low Lower 52NL20 2.40 52NA20 Man-Auto 52NL35 2.40 52NA35 Off 52NL12 2.40 52NA12 Off-On 52NL26 2.40 52NA26 On 52NL11 2.40 52NA11 On-Off-Auto 52NL40 2.40 52NA40 Open 52NL17 2.40 52NA17 Open-Close 52NL34 2.40 52NA34 Out 52NL22 2.40 52NA22 Pull to Start and Push to Stop 52NL47 2.40 52NA47 Raise 52NL19 2.40 52NA19 Raise-Lower 52NL36 2.40 52NA36 Reset 52NL14 2.40 52NA14 Reverse 52NL06 2.40 52NA06 Run 52NL23 2.40 52NA23 Run-Jog 52NL29 2.40 52NA29 52NL27 2.40 52NA27 Safe-Run Slow-Off-Fast 52NL39 2.40 52NA39 Start 52NL03 2.40 52NA03 Start-Jog 52NL28 2.40 52NA28 Start-Stop 52NL32 2.40 52NA32 Stop 52NL04 2.40 52NA04 Stop (red) 52NL04R 2.40 52NA04R Up 52NL09 2.40 52NA09 Up-Down 52NL49 2.40 52NA49 Up-Off-Down 52NL42 2.40 52NA42 Open-Off-Close 52NL41 2.40 52NA41 Inscription plates with custom engraving 52NL02E 10.70 52NA02E 12.40 — –––– — –––– 52NL02RE 52NL02BE 10.70 10.70 52NA02RE 52NA02BE 12.40 12.40 52ND02RE 52ND02BE 10.70 10.70 52NE02RE 52NE02BE 12.40 12.40 Max. number of rows Letter height Characters per row 2 5/32" 14 2 1/4" 16 2 5/32" 14 Pilot Devices "Custom engraved (brushed aluminum)" "Custom engraved (red)" "Custom engraved (Black)" 2 1/4" 16 1) Automotive requires 2 1/2" mounting centers 2) White letters on plastic nameplate. Discount Schedule PILO Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 16-219 Pushbutton Units and Indicator Lights 30 mm Heavy Duty, Watertight/Oiltight, Class 52 Dimensional Drawings Hole Arrangement Standard 4-Way Type 4X Non-Metallic .190 (5) 1.210 (31) .672 (17) CONTROL PRODUCTS 16 Type 12/13 and 4X Stainless Steel Enclosure Size Units 1 2 3 4 6 9 12 162) A 3.50 5.75 8.00 10.25 9.50 9.50 11.75 11.75 Mounting B (89) (146) (203) (260) (241) (241) (298) (298) 3.25 3.25 3.25 3.25 6.25 8.50 8.50 10.75 C (83) (83) (83) (83) (159) (216) (216) (273) Overall G 2.75 2.75 2.75 2.75 3.00 3.00 3.00 3.00 (70) (70) (70) (70) (76) (76) (76) (76) 4.00 6.25 8.50 10.75 10.00 10.00 12.25 12.25 H (102) (159) (216) (273) (254) (254) (311) (311) 2.38 2.38 2.38 2.38 5.38 7.62 7.62 9.88 L (60) (60) (60) (60) (137) (194) (194) (251) W 4.50 6.75 9.00 11.25 10.50 10.50 12.75 12.75 (114) (171) (229) (286) (267) (267) (324) (324) 3.47 3.47 3.47 3.47 6.47 8.72 8.72 10.97 J (88) (88) (88) (88) (164) (221) (221) (279) 2.31 2.31 2.31 2.31 2.56 2.56 2.56 2.56 T (59) (59) (59) (59) (65) (65) (65) (65)2) X 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 6.00 (152) 8.25 (210) 8.25 (210) 10.50 (267) 1.73 (44) 1.73 (44) 1.73 (44) 1.73 (44) 2.11 (54) 2.11 (54) 2.11 (54) 2.11 (54) Y 1.86 (47) 1.86 (47) 1.86 (47) 1.86 (47) 2.61 (66) 2.61 (66) 2.61 (66) 2.61 (66) Type 12/13 Extra Deep Enclosures Enclosure Size Units A 1 2 3 4 6 9 12 162) 4.00 6.00 8.00 10.00 9.50 9.50 B 4.00 4.00 4.00 4.00 6.25 8.50 1 Mounting Overall C G H 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.50 6.50 8.50 10.50 10.00 10.00 12.25 12.25 3.12 3.12 3.12 3.12 5.38 7.62 7.62 9.88 L W 5.00 7.00 4.22 4.22 11.00 4.22 J T 4.31 4.31 4.31 4.31 4.31 3.75 3.75 3.75 3.75 6.00 8.25 8.25 10.50 10.50 12.75 4.31 4.31 10.97 X Y 2.11 2.11 2.11 2.11 2.11 1.98 1.86 1.73 2.11 2.61 2.11 2.61 Type 4X Non-Metallic Enclosure Size Pilot Devices Units3) 1 2 3 4 A 6.00 6.00 8.26 10.51 All dimensions shown in inches and (millimeters). For reference purposes only. Not to be used for design or construction purposes. 16-220 Mounting Overall B C G H L W 3.19 3.19 3.19 3.19 3.63 3.63 3.63 3.63 4.88 4.88 7.13 9.37 2.94 2.94 2.94 2.94 6.63 6.63 8.88 3.81 3.81 3.81 1) Grounding stud in body of enclosure. 2) For stainless steel add 1.75 (45) to depth. 3) No flange for mounting. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 17SPEEDFAX TM 2007-2008 Standby Generators Contents Sandby Power Systems Introduction 17-2 Standby Generators 17-3 Standby Generator Controllers 17-4 Portable Generators 17-5 Transfer Switches 17-6 “SR” Type Transfer Switches 17-7 “X” Type Transfer Switches Manual Transfer Interlock Kits 17-8 17-9 – 17-10 17 STANDBY GENERATORS Residential Commercial Industrial Standby Power Systems NEW Standby Power Systems General Siemens offers a complete line of standby power systems. From standby power generators, portable generators, transfer switches, and manual transfer kits, Siemens has all of your back up power needs covered. You can count on Siemens to deliver high quality, industry leading designs. Our standby generators are designed for quiet operation with sound attenuated enclosures, specially designed fans and radiators, and a high tech enclosure material that provides excellent sound absorption. Standby Generators ▪ Powered by natural gas or liquid propane vapor ▪ Permanently attached to the house via a fuel line and conductors hard wired to the load center ▪ Completely automatic – detects power outages and switches power over to the generator (automatic transfer switch required) ▪ Restores power to pre-selected circuits or entire building ▪ Returns power to utility once restored ▪ Self tests weekly ▪ Available in 7 to 150 kW units, single and three phase Automatic Transfer Switches ▪ Completes the automatic system ▪ Once activated by the generator controller, switches load to and from generator ▪ Available in 100 to 800A versions, single and three phase, indoor and outdoor STANDBY GENERATORS 17 Portable Generators ▪ Gasoline fueled ▪ 15 and 17.5 kW units available, single phase ▪ Provided with 7 various receptacles and circuit protection Mechanical Interlock Kits ▪ Interlocks two main breakers together (generator and utility) such that both cannot be “ON” at the same time ▪ Wide variety of kits available to convert most Siemens load centers and meter combinations into standby power panels For more information including a detailed selection and application guide, generator sizing guides, cut sheets, detailed dimensions, owner’s manuals, and other useful information, visit our web site at www.sea.siemens.com/generators. For technical support, call (800) 844-0029. 17-2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Standby Power Systems Standby Generators Selection 7 through 150 kW 1-Phase, 120/240 Volts AC 3-Phase, 120/208 Volts AC 3-Phase, 277/480 Volts AC Features and Ratings UL 2200 Listed Natural gas or liquid propane vapor options Composite mounting pad provided on air cooled units Automatic Transfer Switch compatibility: Air cooled units compatible with “ST” and “SR” type 20-60 kW units compatible with “SR” type 70-150 kW units compatible with “X” type ▪ 16 kW units and larger are provided with the patented Quiet Test™ feature. This feature allows the generator to run at lower RPM’s during the weekly test cycle, greatly reducing noise pollution. ▪ Rugged, textured paint finish provides superior corrosion resistance ▪ Aluminum enclosure option ideal for harsh environments ▪ ▪ ▪ ▪ Liquid Cooled Generator Air Cooled Generator Catalog Logic Table Siemens Standby Generator kW Rating Generator Information Voltage R=120/240, 1Ø C=120/208, 3Ø I = 277/480, 3Ø Fuel G=Natural Gas P =Propane B=Accepts both Dimensions (inches) Enclosure A=Aluminum S=Steel Controller Type Cooling System Transfer Switch Compatible 007 R B S 48 x 24 x 29 R Air ST, SR SG 010 R B S 48 x 24 x 29 R Air ST, SR SG 013 R B S 48 x 24 x 29 R Air ST, SR R Air ST, SR 016 R B S, A SG 018 R, C B S, A 72 x 30 x 38 R Liquid SR SG 020 R, C B S, A 72 x 30 x 38 R Liquid SR SG 025 R,C B S, A 72 x 30 x 38 R Liquid SR SG 035 R, C, I B S, A 77 x 34 x 46 R Liquid SR SG 045 R, C, I B S, A 77 x 34 x 46 R Liquid SR SG 060 R, C, I G, P S, A 89 x 34 x 48 R Liquid SR SG 070 R, C, I G, P S, A 97 x 37 x 47 H Liquid X SG 080 R, C, I G, P S, A 116 x 37 x 55 H Liquid X H Liquid X SG 100 R, C, I G, P S, A 116 x 37 x 55 SG 130 R, C, I G, P S, A 116 x 37 x 55 H Liquid X SG 150 R, C, I G, P S, A 116 x 37 x 55 H Liquid X Catalog number example Requirements: 1. Standby Generator 2. 35 kW 3. 3-Phase, 120/208 V~ 4. Natural Gas 5. Aluminum Enclosure 1 2 3 4 5 SG 035 C B A STANDBY GENERATORS SG 48 x 24 x 29 Example = SG035CBA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 17 SG 17-3 Standby Power Systems Standby Generator Controllers Selection Siemens standby generators are provided with controllers. The primary purpose of the controller is to monitor utility power, operate the automatic transfer switch, control the weekly self test cycle, and to monitor the generator for any potential system faults. There are two types of controllers, the “R” and “H” types. “R” Type Controller The “R” type controller is provided on all 7 through 60 kW generators. These controllers are compatible with the “ST” and “SR” type transfer switches. Built in governor control is provided, along with LED displays for potential system faults. The automatic transfer switch, which is sold separately, is controlled by the R controller. Control Functions Full system monitoring ▪ Oil Pressure ▪ Coolant Temperature ▪ Engine Speed ▪ Coolant Level ▪ Cranking Time ▪ Starter Lockout ▪ Utility Sensing ▪ Quiet Test™ LED Indicators ▪ Over Speed ▪ Over Crank ▪ Low Oil Pressure ▪ High Coolant Temperature ▪ Low Coolant Level ▪ Low Fuel Pressure ▪ Low Battery Voltage ▪ Quiet Test™ Control “H” Type Controller 17 The “H” type controller is provided on all 70 through 150 kW generators. These controllers are compatible with the “X” type transfer switches. STANDBY GENERATORS Control Functions All R control functions plus: ▪ Full range standby operation ▪ Full system status - 3Ø AC Volts and current - Alternator frequency - kW, kVA, power factor - Fuel pressure - Alarms and warnings - Transfer switch status - Operating hours - Service reminders - Trending - Utility Sensing ▪ Fault protection for generator windings ▪ 3Ø sensing voltage regulator ▪ Isochronous speed regulation 17-4 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog System Features ▪ Two 4-line 20-character LCD displays ▪ Engine governor and voltage regulator built into controller ▪ Hermetically sealed circuit board in a die-cast aluminum enclosure ▪ Waterproof connections ▪ Audible alarm ▪ Service-friendly diagnostics ▪ Built in PLC for user I/O’s ▪ Integrated automatic transfer switch controller for Siemens “X” type transfer switches ▪ Advanced engine sensors eliminate false signals and interference ▪ Quiet-Test™ control ▪ Industry standard 2-wire start Standby Power Systems Portable Generators Selection Portable Generators Portable generators are contained in a steel frame with wheels for easy relocation. The generators are powered by gasoline stored in a provided gas tank. These generators are ideal for locations where space or local codes do not allow a permanently installed standby generator. They are also great for construction site temporary power, eliminating the need for temporary power poles and utility hook ups. Features and Ratings ▪ Provided with 7 receptacles - 12V DC, 10A - 120V AC, 20A Duplex - 120V AC, 20A Duplex GFCI - 120V AC, 30A Locking Type (2) - 120/240V AC, 30A Locking Type - 120/240V AC, 50A Full pressure lubrication ▪ Single point lifting ▪ ▪ Spin-on oil filter ▪ Automatic idle control ▪ Dimensions (in): 39 x 31 x 49 ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ 16 gallon fuel tank Low oil pressure shutdown Solid state voltage regulator GFCI protection Anti-vibration system Circuit breakers included Battery charge cables Maintenance free battery Full 1-1/4" tubular frame Wheel kit Electronic governor Tune-up kit Catalog Number PG015 PG017 햲 Rated Power 15 kW 17.5 kW Surge 22.5 kW 26.2 kW Rated Amps @ 60Hz 120/240, 1Ø, 1.0 pf 62.5 73.0 Engine RPM 3,600 3,600 Engine Cooling Air Air Fuel Capacity (gallons) 16 16 Dimensions (inches) 39 x 31 x 49 39 x 31 x 49 Weight (lbs) 450 475 Manual Transfer Kit 햲 Standby and Portable Generator Maintenance Kits Description Usage GENMKIT1 Oil and air filter kit 7 kW GENMKIT2 Oil and air filter kit 10 kW GENMKIT3 Oil and air filter kit 13, 16 kW GENMKIT4 Oil and air filter kit 20 kW GENMKIT5 Oil and air filter kit 25 kW GENMKIT6 Oil and air filter kit 35, 45 kW GENMKIT7 Oil and air filter kit 60 kW GENMKIT8 Oil and air filter kit 70, 80, 130, 150 kW GENMKIT9 Oil and air filter kit 100 kW GENPAINT Touch up paint All devices PORTMKIT1 Oil and air filter kit Portable 15, 17.5 kW 햲 The 17.5 kW portable generator is provided with a manual transfer kit. The kit includes a load center (G2020L1125CU), factory installed interlock kit (ECSBPK01), a 50A utility main, 50A generator main, a STANDBY GENERATORS Catalog Number 17 Maintenance Kits Generators require routine servicing just like any other engine. It is recommended that the oil and filters be changed once a year, or every 100 hours of use, which ever comes first. Maintenance kits are provided for each engine type and include and oil filter, air filter, spark plugs, and tools. mixture of branch circuits, a 15' power cord, and an inlet box as shown. The kit is not sold separately and is not provided on the 15 kW portable generator. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 17-5 Standby Power Systems Transfer Switches Selection Automatic Transfer Switches There are 3 types of transfer switches. “ST” type transfer switches are provided with branch circuits are compatible with the air cooled generators. “SR” type are compatible with generators containing the “R” type controller (7-60 kW). The “X” type transfer switches are compatible with the “H” type controller (70-150 kW generators). Transfer Switch Catalog Number Logic Transfer Type Enclosure Type T=Indoor R=Outdoor Amperage Voltage R=120/240V 1Ø C=120/208 3Ø I = 277/480V 3Ø S T 100 R S R 100, 200 R S R 100, 200 R, C, I S R 400 R, C R, T 100, 150, 200, 300, 400, 600, 800 R, C, I X “ST” Type Transfer Switches Transfer Switches With Back Up Circuits Siemens offers 3 models of automatic transfer switches with back up circuits. These panels provide transfer capability to a select number of critical circuits, as opposed to the entire house. For the chosen critical circuits, the conductors in the main house panel are removed from the breaker and connected with wire nuts to the pre-wired conductors on the transfer switch. STANDBY GENERATORS 17 Features and Ratings UL 1008 Listed 100A 120/240, 1Ø Indoor NEMA Type 1 Open Transition 10KAIC Express install kit included Dimensions (inches) 27 x 13 x 7 Conduit length: 30 feet from ATS to junction box, 5 feet from junction box to generator, 2 feet from ATS to load center ▪ Suitable for use only on air cooled products (7-16 kW) ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Breakers Provided Catalog Number Q250 Q240 ST100R12 (12 ckt) ST100R10 (10 ckt) ST100R16 (16 ckt) 17-6 1 1 1 Q230 Q220 Q120 Q115 Suggested Use 1 1 3 3 10 kW Generators 3 5 13 kW Generators 5 5 16 kW Generators 1 1 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Service Disconnect D=Provided Branch Circuits Included 10, 12, 16 D D Standby Power Systems “SR” Type Transfer Switches Selection Features and Ratings ▪ ▪ ▪ ▪ ▪ ▪ ▪ UL 1008 Listed 100-400A Outdoor NEMA Type 3R 1-Phase and 3-Phase Open Transition Service entrance rated option Compatible with “R” type controllers found in 7-60 kW generators Voltage Catalog Number Amp SR100R 100 SR100RD 100 SR100C 100 SR100I 100 SR200R 200 SR200RD 200 SR200C 200 SR200I 200 SR400R 400 SR400RD 400 SR400C 400 120/240 1Ø 120/208 3Ø NEMA 277/480 3Ø • • 1 3R 12 • • • • • • • • • • • • • • • • • • • • Service Disconnect Included • • • 100* 200 200* 400 400* 120/240 1Ø 120/208 3Ø 277/480 3Ø 120/240 1Ø 120/240 1Ø 120/208 3Ø 277/480 3Ø 120/240 1Ø 120/240 1Ø 120/208 3Ø 120/240 1Ø Withstand Rating 1Ø 3Ø 10 kAIC 14 kAIC 10 kAIC 10 kAIC 25 kAIC 10 kAIC Dimensions 12/240 & 120/208 277/480 24 x 20 x 7 36 x 24 x 10 24 x 13 x 7 24 x 15 x 7 48 x 30 x 12 24 x 13 x 7 Weight (lbs) 120/240 1Ø 120/208 3Ø 277/480 3Ø 31 49 95 39 31 49 105 40 400 277/480 3Ø 18 kAIC 18 kAIC 18 kAIC 36 x 24 x 10 40 x 30 x 10 35 kAIC 48 x 30 x 12 88 107 100 105 * Service entrance rated, main disconnect provided (type QP for 100A, QN for 200A). Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 17-7 STANDBY GENERATORS 100 Voltage 17 AMPS Standby Power Systems “X” Type Transfer Switches Selection Catalog Number Amp XT100R 100 XT100C 100 XT100I 100 XR100R 100 XR100C 100 XR100I 100 XT150R 150 XT150C 150 XT150I 150 XR150R 150 XR150C 150 XR200I 200 XT200R 200 XT200C 200 XT200I 200 XR200R 200 XR200C 200 XR200I 200 XT300R 300 XT300C 300 XT300I 300 XR300R 300 XR300C 300 XR300I 300 XT400R 400 XT400C 400 XT400I 400 XR400R 400 XR400C 400 XR400I 400 17 XT600R 600 XT600C 600 STANDBY GENERATORS Features and Ratings XT600I 600 XR600R 600 XR600C 600 XR600I 600 XT800R 800 XT800C 800 XT800I 800 XR800R 800 XR800C 800 XR800I 800 UL 1008 Listed 100-800A Indoor NEMA Type 1 and 12 Outdoor NEMA Type 3R 1-Phase and 3-Phase options Open Transition Compatible with “H” type controllers found in 70-150 kW generators ▪ 7 day programmable exerciser ▪ ▪ ▪ ▪ ▪ ▪ ▪ 120/240 1Ø Voltage 120/208 3Ø • • • • • • • • • • • • • • NEMA 277/480 3Ø • • • • • • • • • • • • • • 1 • • • • • • • • • • • • • • • • • • • • • • • • • • 3R • • • • • • • • • • • • • • • • • • • • • • • • 12 • • • • • • AMPS Voltage 100 120/240 1Ø 120/208 3Ø 277/480 3Ø 150 120/240 1Ø 120/208 3Ø 277/480 3Ø 200 120/240 1Ø 120/208 3Ø 277/480 3Ø 300 120/240 1Ø 120/208 3Ø 277/480 3Ø 400 120/240 1Ø 120/208 3Ø 277/480 3Ø 600 120/240 1Ø 120/208 3Ø 277/480 3Ø 800 120/240 1Ø 120/208 3Ø 277/480 3Ø NEMA Rating 1 / 3R 1 / 3R 1 / 3R 1 / 3R 1 / 3R 12 / 3R 12 / 3R 14 kAIC 14 kAIC 10 kAIC 25 kAIC 10 kAIC 25 kAIC 18 kAIC 35 kAIC 18 kAIC 35 kAIC 42 kAIC 42 kAIC 65 kAIC 65 kAIC 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 48 x 30 x 12 36 x 24 x 10 48 x 30 x 12 36 x 24 x 10 48 x 30 x 12 36 x 24 x 10 48 x 30 x 12 66 x 36 x 20 66 x 36 x 20 66 x 36 x 20 66 x 36 x 20 105 120 110 145 110 145 130 165 130 165 650 650 680 680 Withstand Rating 120/240 & 120/208 277/480 Dimensions 120/240 & 120/208 277/480 Weight (lbs) 120/240 & 120/208 277/480 17-8 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Standby Power Systems Manual Transfer Interlock Kits Selection Manual Transfer Interlock Kits These interlock kits are used to interlock two main breakers in a load center or meter combination together so that both cannot be “ON” at the same time. This is required to prevent dangerous feedback between the two power systems. These kits work on most Siemens load centers and meter combinations. Description Catalog Number Breaker Types Utility / Standby Attaches to two double pole circuit breakers across from one another as shown ECSBPK01 QP / QP Attaches to two double pole circuit breakers side by side to one another as shown ECSBPK02 QP / QP Used on Ultimate main breaker load centers 150-225A as shown ECSBPK03 MBK / QP Used on Ultimate main breaker load centers 100-125A as shown ECSBPK04 MBK / QP Attaches to type QN main breakers and double pole breakers as shown ECSBPK05 QN / QP Attaches to type QNR main breakers and double pole breakers as shown ECSBPK06 QNR / QP Image Standard Features ▪ UL listed for use in most Siemens load centers and meter combinations ▪ Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code® ▪ Corrosion resistant finish ▪ Easy assembly requiring no modifications to the load center or meter combination ▪ Remains attached to the main breakers when load center cover is removed Misapplications Follow all directions and precautions detailed in the instructions sheets. Do not use the interlock kits in such a manner that power is not prevented from being fed back to the utility lines when the utility main breaker is in the “OFF” position. Examples would be meter combinations in which the conductors from the meter land on lugs, as opposed to a main breaker (see below). 17 ECSBPK07 QN(R) / QN(R) Attaches to two type QNR or QN main breakers as shown ECSBPK08 QPP / QP Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog STANDBY GENERATORS Attaches to two type QNR or QN main breakers as shown 17-9 Standby Power Systems Manual Transfer Interlock Kits Selection Acceptable Usage of Interelock Kits by Load Center/Meter Combination STANDBY GENERATORS 17 Siemens Outdoor Load Centers W0816B1200CT 3 W0816L1200CT 1 2 W0816ML1125CU 1 2 W1212L1125CU 1 2 4 W1224B1100CU 4 W1224L1125CU 1 2 4 W1224L1200CU 1 2 3 5 W1224L1225CU 1 2 3 5 W1624B1100CU 4 W1624L1125CU 1 2 4 W2020B1100CU 4 W2030L1150CU 1 W2040B1200CU W2040L1200CU W3040B1200CU 3 1 3 2 W3040L1125CU 1 2 4 W3040L1200CU 1 2 3 W4040B1200CU 3 W4040L1200CU 1 W4242B1225CU 3 W4242L1225CU 1 2 2 2 3 3 3 3 3 5 5 5 5 5 5 Siemens Meter Combinations 1 2 MC0816B1150RTH 5 7 E1020MB1100FCGP 1 2 MC0816B1150T 5 7 E1224ML1100* 1 2 MC0816B1150TH 5 7 G1212L1125* 1 2 4 MC0816B1200FCTM 2 G1224B1100* 4 MC0816B1200RT 5 7 G1224L1125* 1 2 4 MC0816B1200RTB 5 7 7 G1224L1200CU 1 2 3 MC0816B1200RTH 5 7 7 G1624B1100* 4 MC0816B1200SCTM 2 G1624L1125* 1 MC0816B1200T 5 7 G1630B1150 3 MC0816B1200TH 5 7 G2020B1100* 4 MC0816B1350RLTM 5 7 G2020L1125* 1 MV0816B1400RLTM 5 7 G2030B1150* 3 MC1224B1100FEC 2 G2030L1125CUSG 1 2 4 MC1224B1100SEC 2 G2030L1150* 1 2 3 MC1224B1125 1 G2040B1200* 3 MC1224B1125FEC 2 G2040L1200* 1 MC1224B1125SEC 2 G2424B1100CU 4 MC1632B1100SEC 2 G2424B1125 4 MC1632B1125FEC 2 G2424L1125 1 MC2040B1150 5 7 G2430B1150 3 MC2040B1200 5 7 G2430L1125CUSG 1 MC2040B1200R 5 7 G2440B1200 3 MC2442B1200FEC 2 G2440L1125CU 1 2 4 MC2442B1200SEC 2 G2440L1200* 1 2 3 MC3040B1200SECW 5 G3030B1100CU 4 MC3042B1200FED 3 G3030B1150* 3 MC3042B1200SED 3 G3030L1200* 1 MC3042B1225FED 3 G3040B1200* 3 MC3042B1225SED 3 G3040L1125CU 1 2 4 MC4040B1200SECW 5 G3040L1200* 1 2 3 MC0816B1200RJBT 8 G4040B1200* 3 MC0816B1150RJBT 8 G4040L1125CU 1 2 4 MC0816B1200RCT 8 G4040L1200* 1 2 3 MC0816B1150RCT 8 G4242B1225CU 3 MC0816B1200CT 8 G4242L1225CU 1 MC0816B1150CT 8 MC2040B1150RCT 9 MC2040B1150CT 9 MC2040B1200RCT 9 MC2040B1200CT 9 7 7 7 7 7 7 Notes ▪ Numbers 1 through 9 in these tables represent the interlock kit number. Example: 1 = ECSBPK01 ▪ Standby power interlock kits are not intended for use with AFCI, GFCI, 3-pole, or 1⁄2" frame breakers ▪ Standby power interlock kits are not intended for use with 4 space, 125A load centers ▪ These kits are not intended for use in meter combination devices where the conductors coming from the meter compartment land on lugs in the load center side, as opposed to a main breaker. Examples would include devices that start with MM0406L, MM0606L, or MC1212L 17-10 Siemens Indoor Load Centers E0816ML1125* 2 2 2 2 2 2 2 5 7 4 4 3 5 5 7 7 4 4 3 3 5 5 5 5 5 7 7 7 7 7 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2 7 7 18SPEEDFAX TM 2007-2008 Technical Contents Siemens Design Assistant Disc Types of Power Distribution Systems Ground Fault Protection 18-2 18-3 – 18-5 18-6 – 18-12 Overcurrent Protection and Coordination 18-13 System Analysis 18-14 Current Limiting Circuit Breaker Technology 18-15 Series-Connected Combination Ratings Harmonics / K-factor Ratings 18-16 18-17 – 18-18 Table 1: Ampacities of Insulated Conductors 18-19 Table 2: Correction Factors for Ambient Temperatures 18-19 Table 4A: Motor Full-Load Currents of Three Phase AC Induction Type Motors 18-20 Table 4B: Motor Full-Load Currents in Amperes, Single Phase AC 18-20 Table 4C: Motor Full-Load Currents in Amperes, DC 18-20 Table 4D: Conversion Table of Polyphase Design 18-20 Table 5: Normal-Load and Fault Currents of Three Phase Transformers 18-20 Table 6: Electrical Formulas for Finding Amperes, Horsepower Kilowatts, and kVA 18-21 18 Table 7: Grounding Electrode Conductor for 18-21 Minimum Size Grounding Conductors for Grounding Raceways and Equipment Molded Case Circuit Breakers Conversion Table Residential Commercial Industrial 18-21 18-22 – 18-24 18-25 TECHNICAL AC Systems Table 8: Technical Reference Siemens Design Assistant Disc To assist consulting electrical engineers and designers, Siemens has introduced the Design Assistant. This disc, available at no charge from your local Consultant Account Manager, includes tools and reference that will make your job easier. Some of the contents are: Design Calculators ▪ Available Fault Current Calculator ▪ Advanced Voltage Drop Calculator ▪ Panelboard Schedule (Excel™ and CADD) ▪ Equipment Sizing Assistant ▪ Conduit Fill Calculator ▪ Circuit Breaker Time Current Curve Program ▪ ▪ ▪ ▪ ▪ ▪ Basic Lighting Calculator Switchboard Heat Output Calculator Switchboard Weight Calculator TVSS Sizing Assistant Motor Data Calculator and more… Training ▪ Step2000 Training Programs (19 books in all), including Basics of Electricity, Drives, Panelboards, MCC’s, PLC’s and Energy Measurement. Specifications ▪ Specifications in Microsoft Word™ format for all our Division 16 and Division 26 products (more than 45 sections), including commissioning TECHNICAL 18 Technical Information ▪ Checklists and Common Forms ▪ CADD Blocks of switchboards and substations ▪ Technical Information and White Papers Reference ▪ All our Selection & Application Guides, brochures, installation manuals, and more ▪ Full pdf versions of our SpeedFax and Industrial Controls Catalogs For a copy of the Siemens Design Assistant Disc, contact your local Consultant Account Manager or Sales Engineer. 18-2 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Technical Types of Power Distribution Systems There are several basic considerations which must be included by the system design engineer to select and design the best power distribution system which will supply power to both present and future loads most economically. Among these are: ▪ Safety ▪ Reliability ▪ Maintenance ▪ Flexibility ▪ Voltage Regulation ▪ Initial Investment ▪ Simplicity of Operation The characteristics of electrical service available at the building site, the types of loads, the quality of service required, and the size and configuration of building are also important factors that will influence system design and circuit arrangement. Four basic circuit arrangements are used for the distribution of electric power. They are the radial, primary selective, secondary selective, and secondary network circuit arrangements. The following discussion of these circuit arrangements covers both the high-voltage and low-voltage circuits. The reader should recognize that the highvoltage circuits and substations may be owned by either the utility company or the building owner, depending upon the electric rates, the practice, and requirements of the particular electric utility serving the specific building site. Figure 2. Expanded Radial System—Single Primary Feeder making it possible to limit outages due to a feeder or transformer fault to the loads associated with the faulted equipment. If circuit breakers are used for primary feeder protection, the cost of this system will be high. Even if fused switches are used, the cost of the arrangement of Figure 3 will exceed the cost of the arrangement of Figure 2. Primary Selective System The circuit arrangement of Figure 4 provides means of reducing both the extent and duration of an outage caused by a primary feeder fault. This operating feature is provided through the use of duplicate primary feeder circuits and load interrupter switches that permit connection of each secondary substation transformer to either of the two primary feeder circuits. Each primary feeder circuit must have sufficient capacity to carry the total load in the building. TECHNICAL A fault in a primary feeder in the arrangement shown in Figure 2 will cause the main protective device to operate and interrupt service to all loads. If the fault were in a transformer, service could be restored to all loads except those served from that transformer. If the fault were in a primary feeder, service could not be restored to any loads until the source of trouble had been eliminated. Since it is to be expected that more faults will occur on the feeders than in the transformers, it becomes logical to consider providing individual circuit protection on the primary feeders as shown in Figure 3. This arrangement has the advantage of Figure 3. Expanded Radial Systems individual Primary Feeder Protection 18 Radial System If power is brought into a building at utilization voltage, the simplest and the lowest cost means of distributing the power is to use a radial circuit arrangement. The radial system is the simplest that can be used, and has the lowest system investment. It is suitable for smaller installations where continuity of service is not critical. The low voltage service entrance circuit comes into the building through service entrance equipment and terminates at a main switchgear assembly, switchboard or panelboard. Feeder circuits are provided to the loads or to other subswitchboards, distribution cabinets, or panelboards. Figure 1 shows the two forms of radial circuit arrangements most frequently used. Under normal operating conditions, the entire load is served through the single incoming supply circuit, and in the case of high voltage service, through the transformer. A fault in the supply circuit, the transformer, or the main bus will cause an interruption of service to all loads. A fault on one of the feeder or branch circuits should be isolated from the rest of the system by the circuit protective device on that circuit. Under this condition, continuity of service is maintained for all loads except those served from the faulted circuit. The need for continuity of service often requires multiple paths of power supply as opposed to the single path of power supply in the radial system. Selection Figure 4. Primary Selective Systems Figure 1. Radial Systems Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-3 Technical Types of Power Distribution Systems TECHNICAL 18 Under normal operating conditions, the appropriate switches are closed in an attempt to divide the load equally between the two primary feeder circuits. Then, should a primary feeder fault occur, there is an interruption of service to only half of the load. Service can be restored to all loads by switching the deenergized transformers to the other primary feeder circuit. The primary selective switches are usually manually operated and outage time for half the load is determined by the time it takes to accomplish the necessary switching. An automatic throwover switching arrangement could be used to avoid the interruption of service to half the load. However, the additional cost of the automatic feature may not be justified in many applications. If a fault occurs in a secondary substation transformer, service can be restored to all loads except those served from the faulted transformer. The higher degree of service continuity afforded by the primary selective arrangement is realized at a cost somewhat higher than a simple radial system due to the extra primary cables and switchgear. Secondary Selective System Under normal conditions, the secondary selective arrangement of Figure 5 is operated as two separate radial systems. The secondary tie circuit breaker in each secondary substation is normally open. The load served from a secondary selective substation should be divided equally between the two bus sections. If a fault occurs on a primary feeder or in a transformer, service is interrupted to all loads associated with the faulted feeder or transformer. Service may be restored to all secondary buses by first opening the main secondary switch or circuit breaker associated with the faulted transformer and primary feeder, and then closing the tie breaker. The two transformer secondary circuit breakers in each substation should be interlocked with the secondary tie breaker in such a manner that all three cannot be in the closed position simultaneously. This prevents parallel operation of the two transformers and thereby minimizes the interrupting duty imposed on the secondary switching devices. It also eliminates the possibility of interrupting service to all loads on the bus when a fault occurs in either a primary feeder or a transformer. The cost of the secondary selective system will depend upon the spare capacity in the transformers and primary feeders. The minimum transformer and primary feeder capacity will be determined 18-4 Selection Figure 5. Secondary Selective System Using Close-Coupled Double-Ended Substation Figure 6. Secondary Selective System Using Two Single-Ended Substations With Cable or Bus Tie by essential loads that must be served under emergency operating conditions. If service is to be provided for all loads under emergency conditions, then each primary feeder should have sufficient capacity to carry the total load, and each transformer should be capable of carrying the total load in each substation. This type of system will be more expensive than either the radial or primary selective system, but it makes restoration of service to all essential loads possible in the event of either a primary feeder or transformer fault. The higher cost results from the duplication of transformer capacity in each secondary substation. This cost may be reduced by shedding nonessential loads. A modification of the secondary selective circuit arrangement is shown in Figure 6. In this arrangement there is only one transformer in each secondary substation, but adjacent substations are interconnected in pairs by a normally open low voltage tie circuit. When the primary feeder or transformer supplying one secondary substation bus is out of service, the essential loads on that substation bus can be supplied over the tie circuit. The operating aspects of this system are somewhat complicated if the two substations are separated by distance. The best arrangement is to use closecoupled, double-ended substations. distributed network or a spot network. If the building demand is in the order of 750 kVA or higher, a spot network will often be established to serve the building. In buildings where a high degree of service reliability is required, and where spot network supply may not be available, the distributed secondary network system is often used. This is particularly true of institutional buildings such as hospitals. The network may take the form of several secondary substations interconnected by low voltage circuits. However, the most common practice is to use some form of the spot network circuit arrangement. Secondary Network System Many buildings with radial distribution systems are served at utilization voltage from utility secondary network systems. The network supply system assures a relatively high degree of service reliability. The utility network may take the form of a Figure 7. Simple Spot Network System Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog A simple spot network, such as shown in Figure 7, consists of two or more identical transformers supplied over separate primary feeder circuits. The transformers are connected to a common low voltage Technical Types of Power Distribution Systems selective switching arrangement with each transformer, or by using three or more transformers. If the primary selective switching arrangement is used, the total load can be about 160 percent of the nameplate rating of one of the transformers. This produces an overload on one transformer until such time as the remaining transformer can be switched to the other feeder in the case of a primary feeder fault. The interrupting duty imposed on the low voltage protective devices in a spot network substation is higher than in radial, primary selective, or secondary selective substations having the same load capability because of the spare transformer capacity required in the spot network substation and because the transformers are operated in parallel. Figure 8. Secondary Network System various load buses. In normal operation, the substations are about equally loaded and the current flowing in the tie circuits is relatively small. However, if a network protector opens to isolate a transformer on a primary feeder fault, the load on the associated bus is then carried by the adjacent network units and is supplied over the tie circuits. This arrangement provides for continuous power supply to all low voltage load buses, even though a primary feeder circuit or a transformer is taken out of service. In the network arrangement in Figure 9, if there were three incoming primary feeder circuits and three transformers, the combined capacity of two of the transformers should be sufficient to carry the entire load on the three substations on the basis that only one feeder is out of service at one time. Generally, these transformers would all have the same ratings. With this arrangement, as with the spot network arrangement, a reduction in spare transformer capacity can be achieved, if a primary selective switching arrangement is used at each substation transformer. However, if three or more primary feeder circuits are available, the reduction in transformer capacity achieved through the use of a primary selective arrangement may be small. Cable ties or busway ties, as shown in Figures 8 and 9, will require careful consideration of load distribution during contingencies and of the safety aspects with regard to backfeeds. Key or other mechanical interlocking of switches or circuit breakers may be essential. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-5 TECHNICAL The spare transformer capacity, the network protectors, and the higher interrupting duty will make the secondary network arrangement much more expensive than the other arrangements. At the same time, these elements make the reliability of the network system greater than for the other system configurations. The secondary network may also take the form shown in Figure 8. In this arrangement there is only one transformer in each secondary substation, and the substations are interconnected by normally closed low voltage tie circuits. The tie circuits permit interchange of power between substations to accommodate unequal loading on the substations and to provide multiple paths of power flow to the Figure 9. Primary Selective Secondary Network System 18 bus through network protectors and are operated in parallel. A network protector is an electrically operated power circuit breaker controlled by network relays in such a way that the circuit breaker automatically opens when power flows from the low voltage bus toward the transformer. When voltages in the system are such that power would flow toward the low voltage bus from the transformer, it will close automatically. Network protectors are normally equipped with relays which operate for faults in the network transformer or high voltage feeder only. The network is often operated on the assumption that network failure will “burn” open. Network protectors without supplementary protection do not meet the requirements of the NEC for overcurrent, ground fault, or short circuit protection. Protection of the network or collector bus may be added by providing sensing devices, including ground fault detection, with tripping of the network protectors. The most common use of the network protector, however, has been by utilities in vaults where failure of the network devices could cause damage limited to the vault. High integrity design involving wide phase separation and the use of “catastrophe” fusing minimize the danger and extent of a network failure. A conventional circuit breaker with time overcurrent and instantaneous trip devices plus network relays can meet the NEC requirements. However, the full reliability of the network may be compromised since selectivity between these devices is difficult to obtain. Under normal operating conditions, the total load connected to the bus is shared equally by the transformers. Should a fault occur in a transformer or on a primary feeder, the network protector associated with the faulted transformer or feeder will open on reverse power flow to isolate the fault from the low voltage bus. The remaining transformer or transformers in the substation will continue to carry the load and there will be no interruption of service to the loads, except for a voltage dip during the time that it takes for the protective equipment to operate. If only two transformers are used in a spot network substation, each transformer must be capable of carrying the total load served from the low voltage bus. The amount of spare transformer capacity in the substation can be reduced by using a primary Selection Technical TECHNICAL 18 Ground Fault Protection The term “low magnitude” arcing ground fault is a deceptive description of this type fault. What is meant by this is that the fault current magnitude is low compared to that of a bolted fault. Even so, the arc energy released at the point of the fault can cause much damage and may result in a fire. A ground fault is an insulation failure between an energized conductor and ground. A phase-to-ground arcing fault, unlike a phase-to-phase bolted fault, is a high-impedance type fault. The factors that contribute to this high impedance are the resistance of the arc and the impedance of the return path. This return path is usually metal conduit, raceway, busway housing or switchboard frames. Another contributing factor is the spasmodic nature of the arc. The circuit breaker or fuse protecting the circuit detects the fault current, but the actual ground fault current magnitude is ever changing due to arc elongating blowout effects, self-clearing attempts and arc reignition. These current limiting effects make the circuit breaker or fuse incapable of detecting the actual damage that is occurring. This is not to imply that these devices are inadequate. The problem is one of system protection because the circuit breaker must be adjusted (or fuse size selected) so as to hold without tripping under momentary overload conditions, such as motor starting current or transformer inrush current. Therefore, the circuit breaker or fuse cannot open quickly enough under relatively low magnitude faults to limit the arcing damage. Figure 10 illustrates the basic problem. Shown is a typical distribution system with a 1600 ampere main service entrance unit with a circuit breaker (single line “a”) or fused service protector (single line “b”). A ground fault of 1500 amperes on the bus would affect but would not open either device. A 4000 ampere ground fault would be cleared in approximately 35 seconds by the circuit breaker and in 230 seconds by the fuse. To allow a fault of this magnitude to persist for this length of time would create more than 92,000 kW seconds of arc energy. As a result of tests made, it has been determined that an arc with a value of 1050 kW seconds of energy would vaporize about 1.0 cubic in. of copper or 2.5 cubic in. of aluminum. Obviously a fault of the magnitude shown in Figure 10 could cause a considerable amount of damage. The nature of low-level arcing ground faults makes impractical their detection 18-6 Selection Figure 10. Ground Fault Protection by a traditional overcurrent devices. To complete total protection of the system against all possible types of faults, other means are utilized to detect ground fault currents, including: ▪ Zero sequence method ▪ Source ground current (or ground return) method ▪ Residual connection method Zero Sequence Method This is commonly used when ground fault protection is provided for equipment employing electromechanical trip devices. The scheme uses a core balance type current transformer (ground sensor) which encircles all phase conductors (and neutral on four wire system) to detect ground faults. The operation of this system is such that under normal operating conditions (eg., no ground fault on the system) there is Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog no output from the ground sensor to the tripping relay because the vector sum of all the currents through the sensor window is zero. (Ia + lb + Ic + In = 0) If a ground fault occurs on the system, there is now an additional current (Ig) seen by ground sensor which returns to the source by a path other than through the sensor window. The sensor now sees an unbalance caused by Ig and operates the ground relay which trips the circuit protector. (Ia + lb + lc + In = Ig) The ground sensor is located downstream from the point at which the system is grounded and can be mounted either on the line side or load side of the main disconnect device. This method can be used on incoming main disconnect or on feeders. Technical Ground Fault Protection Source Ground Current (or Ground Return) Method This method of detecting the ground fault current Ig locates the ground sensor on the neutral connection to ground at the service entrance. This means that the ground sensor only detects ground fault current. This type of detection has some limitations because it is detecting the ground fault return current. On multiple source systems with multiple connections to ground, this ground fault current can return by more than one path, therefore, some sensitivity in detecting these faults would be lost. Residual Connection Method Current sensors, one on each of the phase conductors and on the neutral conductors, are connected in common. This common (or residual connection) measures the vector summation of the phase currents and the neutral current. Under normal conditions, this vector summation will be zero, and no current will be applied to the ground relay. If a fault involving ground occurs, the current summation is not equal to zero. Current flows into common connection which is applied to the relay. This method of detecting ground fault current is used in circuit breakers with electronic trip device. Selection Figure 11. Schematic for Zero Sequence Figure 12. Schematic for Source Ground Current GFS = Ground Fault Sensor GFP = Ground Fault Protection (Relay or Trip Unit) Residual Ground Current Sensing Figure 13. Schematic for Residual Method 18 TECHNICAL 3-Wire System This system is used with electronic trip units, and always includes three current sensors mounted on the circuit breaker. A trip element is connected in series with each sensor to provide phase overcurrent protection. By adding a ground trip element in the residual (neutral) circuit of the three current sensors, it will sense ground fault current only, and not load current. This permits more sensitive settings to protect against low magnitude ground faults. This scheme is shown in Figure 14. Under normal conditions, the vector sum of the current in all of the phases equals zero. No current would flow in the GND element, which is also true under the condition of a phase-to-phase fault. A phase-to-ground fault would cause a current to flow in the GND trip element. If the magnitude of this current exceeds the pickup setting for the required time, the trip unit will operate to trip the breaker. Figure 14. Schematic for Ground Protection on 3-Wire Systems, Residual Sensing Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-7 Technical Ground Fault Protection 4-Wire System To avoid false tripping, a fourth current sensor is connected in the neutral conductor to sense normal neutral current. This fourth sensor is connected so that it cancels the normal neutral current which is developed in the residual circuit as shown in Figure 15. Under normal conditions, the vector sum of the current in all phases equals the neutral current. Disregarding the effects of the neutral sensor connection, the neutral current would flow through the GND element. Since this is normal neutral current, pickup of the GND element is not desired. Therefore, the neutral sensor is added to sense the same neutral current as the GND sensor — but opposite in polarity. The result is a circulating current between the phase sensing current sensors and the neutral sensor, with no current flowing through the GND sensor. This is similar to a differential relay circuit. When a phase-toground fault occurs, the vector sum of the phase currents will no longer equal the neutral current because the ground Selection Figure 15. Schematic for Ground Protection on 4-Wire Systems, Residual Sensing fault current returns via the ground bus and bypasses the neutral. If the magnitude of the phase-to-ground current exceeds the pickup setting of the GND element for the required time, the trip unit will operate to open the breaker. Types Of Coordinated Ground Fault Tripping Systems TECHNICAL 18 There are two types of Coordinated Ground Fault Systems: ▪ Time / Current Selective ▪ Zone Selective (Zone Interlock) Time / Current Selective In this system the time / current characteristics of the Ground Fault Protection (GFP) devices used with each disconnect are coordinated so that the nearest disconnect supplying the ground fault location will open. Any upstream disconnects remain closed and continue to supply the remaining load current. Each set of GFP devices should have a specified time-current operating characteristic. When disconnects are connected in series, each downstream device should use a time-current setting that will cause it to open and clear the circuit before any upstream disconnect tripping mechanism is actuated. The timecurrent bands of disconnects in series must not overlap and must be separated from each other sufficiently to allow for the clearing time of each disconnecting means used. The time / current selective system is recommended for applications where damage levels associated with the time / current settings used are tolerable. This type of system does not require 18-8 interlocking wiring between the GFP devices associated with main feeder and branch disconnecting devices. Figure 16, on the next page, illustrates time / current selective coordination in a system involving a 4000 ampere main circuit breaker and a 1600 ampere feeder circuit breaker in an incoming service switchboard. These feed a distribution switchboard with a 600 ampere subfeeder to a 100 ampere branch breaker. The system is coordinated so that only the circuit breaker nearest the location of the ground fault trips. Zone Selective (Zone Interlock) In this system each disconnecting means should open as quickly as possible when a ground fault occurs in the zone where this disconnect is the nearest supply source. The GFP device for an upstream disconnecting means should have at least two modes of operation. If a ground fault occurs between it and the nearest downstream disconnect, it should operate in its fast tripping mode. When a ground fault occurs beyond the downstream disconnect, the downstream GFP device should open in its fast tripping mode and simultaneously Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog send a restraining signal to the upstream device and transfer that device to a timedelay tripping mode. The upstream timedelay tripping characteristic selected should be such that the downstream disconnect will open and clear the circuit before the upstream disconnect tripping mechanism is actuated. The time-current characteristic of the upstream device should be such as to offer backup protection in the event of malfunction of the downstream equipment. Alternatively, a restraining signal from a downstream device may be used to prevent the tripping of an upstream disconnect on ground fault instead of causing it to operate in the time-delay tripping mode. This may be done where backup protection is less important than continuity of service to critical loads supplied by the upstream unit. There are very few instances in which this is justified, and a careful study of the entire system should be made before using this type of interlocking. For a zone selective system, the timecurrent bands of disconnects in series, although used only for backup protection, should not overlap and should be separate from each other sufficiently to allow for the opening time of each disconnecting means used. Technical Ground Fault Protection Selection Time/Current Selective Ground Coordination Figure 17. Zone Interlocking Scheme The zone selective or zone interlock scheme is for those few special applications where exceptionally fast tripping is necessary for all feeders throughout the entire system to reduce damage. Note that although the relay time can be reduced appreciably, the circuit breaker mechanism and arcing time (plus safety margin) will still be present. Table 17.1 Typical Ampere Setting Restrained Time Delay 800 400 100 10 0.4 SEC. 0.3 SEC. 0.2 SEC. 0.1 SEC. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-9 TECHNICAL The zone selective or zone interlock system provides fast tripping of the nearest disconnect upstream of the ground fault. The damage level is the lowest that is possible because the ground fault is cleared as quickly as the protective equipment can respond and the disconnect can open. Additional interlocking wiring and circuity for sending and receiving the restraining signals are required. 18 Figure 16. Fully Coordinated Multizone GFP System Zone Selective Operation (Figure 17): a) Relay-1 will sense a ground fault at A when it exceeds 10 amperes. It will instantly initiate tripping of the Branch breaker and send restraining signals (transfer from instantaneous operation to time-delayed operation) to Relay-2 and Relay-3 (Relay-2 and Relay-3 will then back up Relay-1 on a time coordinated basis). Relay-4 will be restrained by Relay-2 if ground fault exceeds 100 amperes. b) Relay-2 will sense a ground fault at B when it exceeds 100 amperes. It will instantly initiate tripping of the Sub-Feeder breaker and send restraining signals to Relay-3 and Relay-4. c) Relay-3 will sense a ground fault at C when it exceeds 400 amperes. It will instantly initiate tripping of the Feeder breaker and send a restraining signal to Relay-4. d) Relay-4 will sense a ground fault at D when it exceeds 800 amperes. It will instantly initiate tripping of the Main breaker. Technical Ground Fault Protection Typical Application Diagrams Figures 18 through 23 on this and the facing page show the basic methods of applying ground fault protection (GFP). Other types of distribution systems will require variations of these methods to satisfy other system conditions. These diagrams show circuit breakers as the disconnects. Any disconnecting Table 17.2 Selection means can be utilized, providing it is suitable for use with a ground fault protection system as indicated in the scope of this application guide. The examples do not show protection against a ground fault on the supply side of the main disconnect. Sensing device and disconnect locations define zones of protection. Source side Recommendations for Figures 18-23 Ground Fault Protection On Main Disconnect Only On Main and Feeder Disconnects On Main, Feeder, and Selected Branch Disconnects with Zone Selective Interlocking Double-Ended System with Protection on Main and On Tie and Feeder Disconnects Figure Sensing Method Additional Ground Points 18 Vector Summation Must not be downstream. May be upstream 19 Ground Return None 20 Main and Feeders– Vector Summation Must not be downstream of main ground fault sensor. May be upstream. 21 Main – Ground Return Feeders – Vector Summation 22 Main and feeders 1-3 – Vector Summation MCC branch feeder A – Zero Sequence 23 Main and Tie – Ground Return Feeders – Vector Summation Recommended Use Limited selectivity depends on location of fault and rating of overcurrent devices on the upstream side of fault. Improved service continuity is required Main will allow feeder to trip for faults downstream of feeder sensors, but main will trip if feeder fails to operate. None Must not be downstream of main ground fault sensor. May be upstream. Improved service continuity and minimum arcing fault damage are required and protection is needed on branch circuits. Double-ended systems with ground fault protection on tie disconnect where maximum continuity of service is essential. None 18 TECHNICAL 18-10 Selectivity Minimum protection only per Section 230-95 for the National Electric Code Ground Fault Protection on Main Disconnects Only Figure 18 and ground return sensors provide protection only on the load side of associated disconnects. If a vector summation method is used and its sensors are located on load side of a disconnect, the zone between a source and actual sensor location becomes the responsibility of the next upstream protective device. Figure 19 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Main and feeder 1-3 will provide delayed backup protection if fault is downstream of MCC branch feeder A. Main will provide delayed backup protection if fault is downstream of sensors for feeders 1-3. Main will trip on fastest curve if fault is upstream of sensors for feeders 1-3. When operating with tie disconnect open, main will provide delayed backup protection if fault is downstream from feeder sensors. When operating with the tie disconnect closed, the tie will trip before the main, thus sectionalizing the bus. Technical Ground Fault Protection Selection Ground Fault Protection on Main and Feeder Disconnects Figure 20 Figure 21 Ground Fault Protection on Main, Feeder and Selected Branch Disconnects with Zone Selective Interlocking Double-Ended System with Ground Fault Protection on Main and on Tie and Feeder Disconnects Figure 23 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-11 TECHNICAL Figure 22 18 Note: Interlocking Supplementary interlocking is required but will vary depending on equipment used. Technical Ground Fault Protection TECHNICAL 18 NEC Requirements for Ground Fault Protection 230.95 Ground-Fault Protection of Equipment. Ground-fault protection of equipment shall be provided for solidly grounded wye electrical services of more than 150 volts to ground but not exceeding 600 volts phase-to-phase for each service disconnect rated 1000 amperes or more. The grounded conductor for the solidly grounded wye system shall be connected directly to ground without inserting any resistor or impedance device. The rating of the service disconnect shall be considered to be the rating of the largest fuse that can be installed or the highest continuous current trip setting for which the actual overcurrent device installed in a circuit breaker is rated or can be adjusted. Exception No. 1: The ground-fault protection provisions of this section shall not apply to a service disconnect for a continuous industrial process where a nonorderly shutdown will introduce additional or increased hazards. Exception No. 2: The ground-fault protection provisions of this section shall not apply to fire pumps. (A) Setting. The ground-fault protection system shall operate to cause the service disconnect to open all ungrounded conductors of the faulted circuit. The maximum setting of the ground-fault protection shall be 1200 amperes, and the maximum time delay shall be one second for ground-fault currents equal to or greater than 3000 amperes. (B) Fuses. If a switch and fuse combination is used, the fuses employed shall be capable of interrupting any current higher than the interrupting capacity of the switch during a time that the ground-fault protective system will not cause the switch to open. (C) Performance Testing. The groundfault protection system shall be performance tested when first installed 18-12 Selection on site. The test shall be conducted in accordance with instructions that shall be provided with the equipment. A written record of this test shall be made and shall be available to the authority having jurisdiction. (FPN No. 1): Ground-fault protection that functions to open the service disconnect affords no protection from faults on the line side of the protective element. It serves only to limit damage to conductors and equipment on the load side in the event of an arcing ground fault on the load side of the protective element. (FPN No. 2): This added protective equipment at the service equipment may make it necessary to review the overall wiring system for proper selective overcurrent protection coordination. Additional installations of ground-fault protective equipment may be needed on feeders and branch circuits where maximum continuity of electrical service is necessary. (FPN No. 3): Where ground-fault protection is provided for the service disconnect and interconnection is made with another supply system by a transfer device, means or devices may be needed to ensure proper ground-fault sensing by the ground-fault protection equipment. (FPN No. 4): See 517.17(A) for information on where an additional step of ground fault protection is required for hospitals and other buildings with critical areas or life support equipment. 517.17 Ground-Fault Protection. (A) Applicability. The requirements of 517.17 shall apply to hospitals and other buildings (including multiple occupancy buildings) with critical care areas or utilizing electrical life support equipment, and buildings that provide the required essential utilities or services for the operation of critial care areas or electrical life support equipment. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog (B) Feeders. Where ground-fault protection is provided for operation of the service disconnecting means or feeder disconnecting means as specified by 230.95 or 215.10, an additional step of ground-fault protection shall be provided in all next level feeder disconnecting means downstream toward the load. Such protection shall consist of overcurrent devices and current transformers or other equivalent protective equipment that shall cause the feeder disconnecting means to open. The additional levels of ground-fault protection shall not be installed as follows: (1) On the load side of an essential electrical system transfer switch (2) Between the on-site generating unit(s) described in 517.35(B) and the essential electrical system transfer switch(es) (3) On electrical systems that are not solidly grounded wye systems with greater than 150 volts to ground but not exceeding 600 volts phase-to-phase. (C) Selectivity. Ground-fault protection for operation of the service and feeder disconnecting means shall be fully selective such that the feeder device, but not the service device, shall open on ground faults on the load side of the feeder device. A six-cycle minimum separation between the service and feeder ground-fault tripping bands shall be provided. Operating time of the disconnecting devices shall be considered in selecting the time spread between these two bands to achieve 100 percent selectivity. (FPN): See 230.95, fine print note, for transfer of alternate source where ground-fault protection is applied. (D) Testing. When equipment groundfault protection is first installed, each level shall be performance tested to ensure compliance with 517.17(C). Technical Overcurrent Protection and Coordination plotted on standard log-log coordination paper to facilitate the coordination study. Mechanics Of Achieving Coordination: The process of achieving coordination among protective devices in series is essentially one of selecting individual units to match particular circuit or equipment protection requirements, and of plotting the time/current characteristic curves of these devices on a single overlay sheet of log-log coordination paper. The achievement of coordination is a trialand-error routine in which the various time / current characteristic curves of the series array of devices are matched one against another on the graph plot. When selecting protective devices one must recognize ANSI and NEC requirements and adhere to the limiting factors of coordination such as load current, short-circuit current, and motor starting. The protective devices selected must operate within these boundaries while providing selective coordination where possible. Selective coordination is usually obtained in low voltage systems when the log-log plot of time / current characteristics displays a clear space between the characteristics of the protective devices operating in series, that is, no overlap should exist between any two time/current characteristics if full selective coordination is to be obtained. Allowance must be made for relay overtravel and for relay and fuse curve accuracy. Quite often the coordination study will stop at a point short of complete selective coordination because a compromise must be made between the competing objectives of maximum protection and maximum service continuity. Computer Aided Coordination: The philosophy discussed above applies to the “classical” practice of performing coordination studies manually. Today, however, there are numerous personal computer software programs available for performing coordination studies. 18 TECHNICAL Coordination of a power distribution system requires that circuit protective devices be selected and set so that electrical disturbances, such as over-loads or short circuits, will be cleared promptly by isolating the faulted equipment with minimum service disruption of the distribution system. Time / Current Characteristic Curves are available for circuit protective devices, such as circuit breakers and fuses, which show how quickly they will operate at various values of overload and short circuit current. Coordination can be obtained by comparing these curves for each device in series in the system. In developing the system, it will be noted that many compromises must be made between the various objectives: 1. System reliability. 2. Continuity of service. 3. Equipment and system protection. 4. Coordination of protective devices. 5. System cost. Preliminary steps in Coordination study: A) One-line diagram: used as a base on which to record pertinent data and information regarding relays, circuit breakers, fuses, current transformers, and operating equipment while at the same time, providing a convenient representation of the relationship of circuit protective devices with one another. B) Short-circuit study: record all applicable impedances and ratings; using these values, a short-circuit study is made to determine currents available at any particular point in the system. C) Determine maximum load currents which will exist under normal operating conditions in each of the power-system circuits, the transformer magnetizing inrush currents, and times, and the starting currents, and accelerating times of large motors. These values will determine the maximum currents which circuit protective devices must carry without operating. The upper boundary of current sensitivity will be determined by the smallest values resulting from the following considerations: 1) Maximum available short-circuit current obtained by calculation. 2) Requirements of applicable codes and standards for the protection of equipment such as cable, motors, and transformers. 3) Thermal and mechanical limitations of equipment. D) Time / current characteristic curves of all the protective devices to be coordinated must be obtained. These should be Selection Figure 24. Coordination of Example System Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-13 Technical TECHNICAL 18 System Analysis General Proper system design requires that the system be coordinated so the interrupting capacity and / or short circuit withstand capabilities of the various components in the system are not exceeded for any operating situation. Good practice also requires that the system be selective, that is, that the minimum portion of the system be interrupted on occurrence of a fault. The need for selectivity must always be balanced against the requirements of economics and coordination with the overall process needs. At the conceptual phase of a project, several distribution system alternatives should be considered, and examined both technically and economically. This study should include sufficient detail for a thorough understanding of the system alternatives. The conceptual study should determine the optimal distribution system configuration for the project, on which definitive design can proceed. At all stages of design, the principal objectives of personnel safety, equipment protection, process continuity, fault clearing, and service continuity should be considered. In designing a new or modified distribution system, the following types of system studies may be needed: 1. Short Circuit Studies: three phase, line-to-line, and line-to-ground faults can be calculated for both close-andlatch and interrupting conditions, necessary for checking interrupting device and related equipment ratings, and setting protective devices. 2. Circuit Breaker Application Studies: consider the AC and DC decrements in the fault current, and the speed of the various medium voltage circuit breakers, to determine close-and-latch and interrupting duties. 3. Protective Device Coordination Studies: determine characteristics and settings of protective devices, e.g., relays, trip devices, fuses, etc. The coordination study should provide a balance between protection of system equipment and continuity of service. Selection 4. Load Flow Studies: calculate voltages, phase angles, real and reactive power, line and transformer loadings under simulated conditions to aid in determining the performance of a new or revamped system during the planning stage. 5. Motor Starting Studies: determine severity of voltage dips and adequacy of load accelerating torque when starting large motors on a weak system. Today, most studies are performed using computers. Some specialized studies require large computing resources, but many studies can now be performed on personal computers. A wide variety of software packages are available. In addition, many specialty firms exist which provide engineering service to perform such studies. Short Circuit Calculations The single-line diagram serves as the starting point for the system study and selection of equipment ratings. The single-line must be modified to show all power sources and capacities, and system impedances. Sources of short circuit current include utility connections, local generation, and all rotating machines connected to the system at the instant the fault occurs. The system study should consider various fault types (line-to-line and line-to-ground) and fault locations. The value of normal load current in a circuit depends on the load connected, and is essentially independent of the capacity of the power system. On the other hand, the short circuit current depends almost entirely on the capacity of the power system, not the size of the load. The total fault current consists of a symmetrical AC component, superimposed on a DC (offset) component. Hence, the total fault current is asymmetric with respect to the current axis. The value of the DC component depends on the point of the voltage wave at which the fault was initiated. For system studies, it is assumed that the fault is initiated at the worst point, to produce a “fully offset” fault current. This is illustrated in Figure 25. Short circuit currents are determined by the system impedance, including both reactance and resistance. The effect of the reactance is to cause the initial fault current to be high, with the fault current declining as time proceeds. This is represented as the summation of a DC component which decays relatively rapidly over time, and an AC component, which decays at a slower rate. The rate of decay of the components depends on the system X / R ratio. Since the reactance of rotating machines varies with the time from fault initiation, the short circuit calculations must use the appropriate machine reactance values. Subtransient reactance (X”d) governs current flow for approximately the first 6 cycles of a fault. Then, transient reactance (X’d) determines current flow up to around 30-120 cycles, depending on the machine. After this, synchronous reactance (Xd) applies, but studies seldom use this value as faults are not usually allowed to persist for this length of time. For transformers, the actual tested value of the transformer impedance is used. If this is not available, use design impedance adjusted to the minimum value allowed by manufacturing tolerance of + – 7.5%. For example, a 5.75% design unit has a tolerance range of 5.32-6.18%, and 5.32% would be used in a system study prior to manufacture. Figure 25. Structure of Asymmetrical Current Wave (Fully Offset) 18-14 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Technical Current Limiting Circuit Breaker Technology Fuseless Current Limiting Circuit Breakers The technology of Siemens Sentron® fuseless current limiting circuit breakers was developed to meet the demands of modern distribution systems. It is not uncommon for today’s systems to have prospective short circuit currents approaching 200,000 amperes. Users demanded the protection and flexibility afforded by circuit breakers, without the nuisance and expense of fuse replacement. Underwriters Laboratories, in UL4892.4A, defines a fuseless current limiting circuit breaker as one that “does not employ a fusible element, and that when operating within its current-limiting range, limits the let-through l2t to a value less than the l2t of a half-cycle wave of the symmetrical prospective current.” l2t is an expression which allows comparison of the energy available as a result of fault current flow. As used in current limiting discussions, l 2t refers to the energy released between the initiation of the fault current and the clearing of the circuit. Figure 26 relates the “prospective l2t” to the energy allowed by a Sentron current limiting circuit breaker, or “let-through l2t”. The upper curve represents the maximum I2 the circuit can produce, unaltered by the presence of any protective device. The lower curve illustrates the reduction in energy allowed when Sentron current limiting circuit breakers are used. Selection The Sentron circuit breakers use the “blow-apart” contact principle to accomplish current limitation. This principle is based on the electro-magnetic repulsion of adjacent conductors which carry current in opposite directions. The contact arms are arranged to create opposing magnetic fields. As fault current rises, magnetic repulsion forces the contacts to separate completely. The higher the fault current, the faster this “blow-apart” action occurs. As figure 27 illustrates, the energy letthrough with the current limiting Sentron circuit breaker is decreased significantly. This provides better protection for downstream equipment, and reduces damage. Figure 26. Reduction of l2t Let-Through with Current-Limiting Technology Applications and Ratings Sentron current limiting circuit breakers are designed for use in load centers, power panelboards, distribution switchboards, secondary unit substations, and all types of individual enclosures where the available fault currents exceed the interrupting ratings of heavy duty and extra-heavy duty molded case circuit breakers. Sentron circuit breakers have ratings of 15 through 1600 amperes, 240 through 600 volts AC, with up to 200,000 symmetrical amperes interrupting rating. Figure 27. Current Limitation TECHNICAL Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18 Figure 27 illustrates how the Sentron circuit breaker limits the energy under fault conditions. The upper curve illustrates the first half-cycle wave of prospective fault current. To qualify as truly current limiting, the circuit breaker must prevent the current value from reaching the maximum value that it would reach if the circuit breaker were not connected in the circuit. 18-15 Technical Series-Connected Combination Ratings TECHNICAL 18 Series-Connected Rating A series-connected rating can be assigned to a combination of components — typically circuit breakers — which has been tested in combination to a higher interrupting rating than that of the lowest rated protective device of the combination. These ratings must be substantiated by extensive UL testing. General Article 110.9 of the 2005 National Electric Code states the following: “Equipment intended to interrupt current at fault levels shall have an interrupting rating sufficient for the nominal circuit voltage and the current that is available at the line terminals of the equipment. Equipment intended to interrupt current at other than fault levels shall have an interrupting rating at nominal circuit voltage sufficient for the current that must be interrupted.” The difference between the phrases “at fault levels” and “at other than fault levels” is the part of the Code which makes series-connected systems possible. For example, the traditional method of satisfying the Code was to select each breaker in the series with an interrupting rating equal to or greater than the prospective fault current. The interrupting rating of a circuit breaker — stated in RMS symmetrical amperes — is the amount of short circuit current the device can safely interrupt and continue to function as a circuit breaker. Thus, if the prospective fault current at the line terminals of a panelboard is 100,000A RMS symmetrical, this traditional method would require that all the circuit breakers within the panelboard be rated at 100,000A RMS symmetrical or greater interrupting capacity. This is illustrated in Figure 28. In the traditional system, both the main and the feeder breaker are subjected to several short circuit peaks. Figure 28 — Without Current Limiting 18-16 Selection In a series-connected system, however, the individual components (or circuit breakers) have already been tested in series and the combination has been given an interrupting rating equal to or greater than various prospective fault currents which are available. The combination, therefore, acts as a single entity, and performs the same protective function as individual circuit breakers in the traditional method. The difference is that combinations in series-connected systems contain devices with lower interrupting ratings. Siemens circuit breakers used in series combinations which have passed extensive tests required by Underwriters Laboratories are listed in the UL Recognized Component Directory according to manufacturer’s name and type. The listing means that such circuit breakers are UL Recognized for the series interrupting ratings as noted in the Directory, and that they can be used as an entity to meet Article 110.9 of the NEC. Using the previous example, if the prospective fault current at the line terminals of the panelboard is 100,000 amperes RMS symmetrical, the seriesconnected method would involve selecting a specific combination from the UL Recognized Component Directory with a rating of 100,000 amperes RMS symmetrical or greater interrupting capacity. That combination might include individual components which have lower individual interrupting ratings than 100,000 amperes RMS symmetrical. However, all the components in the combination have been tested together and form an entity that will safety interrupt the prospective fault current of the particular situation being examined as long as the interrupting rating listed matches the prospective fault current. With the advent of fuseless current limiting circuit breakers such as Sentron, another important development in seriesconnected combinations has emerged. Because of the fuseless current limiting circuit breaker’s extremely fast interrupting capability, this device provides more control over high prospective fault currents than traditional series-connected systems. The concept behind using fuseless current limiting circuit breakers as a component in a series-connected system is twofold: (1) higher interrupting ratings, and (2) increased control over peak current (ip) and energy let-through (I2t). For example, a current limiting circuit breaker is placed at the side closest to the source of power and rated according to the prospective fault current available at the line-side terminals. In effect, doing this places a “shroud of protection” over the downstream components. Because of the inherent high interrupting capability of the current limiting circuit breaker, the breaker itself meets or exceeds the prospective short circuit current. Because of its current limiting action the prospective I2t never reaches downstream components. This is illustrated in Figure 29. It is important to recognize that the current limiting circuit breaker be an individual component in a UL tested combination, and that it is the combination itself — current limiting circuit breaker plus other circuit breakers — that forms entity specified in day-to-day applications. For specific series-connected combinations that have met UL requirements and are listed in the UL Recognized Component Directory, check with your local Siemens sales office listed on the back cover. Since the Directory is updated every six months, please check for additional combinations which may have been tested and approved. Figure 29 — Series-Connected Protective Scheme With Current Limiting Main Circuit Breaker Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Technical Harmonics / K-factor Ratings Non-Linear Loads When a sinusoidal voltage is applied to a linear load, the resultant current waveform takes on the shape of a sine wave as well. Typical linear loads are resistive heating and induction motors. In contrast, a non-linear load either: ▪ Draws current during only part of the cycle and acts as an open circuit for the balance of the cycle, or Changes the impedance during the ▪ cycle, hence the resultant waveform is distorted and no longer conforms to a pure sine wave shape In recent years, the use of electronic equipment has mushroomed in both offices and industrial plants. These electronic devices are powered by switching power supplies or some type of rectifier circuit. Examples of these devices used in offices are: computers, fax machines, copiers, printers, cash registers, UPS systems, and solid-state ballasts. In industrial plants, one will find other electronic devices such as variable speed drives, HID lighting, solid-state starters and solid-state instruments. They all contribute to the distortion of the current waveform and the generation of harmonics. As the use of electronic equipment increases and it makes up a larger portion of the electrical load, many concerns are raised about its impact on the electrical power supply system. Voltage of Current Waveform for Linear Loads (Sine Wave) Typical Current Waveform of Switching Power Supply A Non-Linear Current and Its Fundamental, Plus 3rd and 5th Harmonic Components 18 TECHNICAL Harmonics As defined by ANSI / IEEE Std. 519-1992, harmonic components are represented by a periodic wave or quantity having a frequency that is an integral multiple of the fundamental frequency. Harmonics are voltages or currents at frequencies that are integer multiples of the fundamental (60 Hz) frequency: 120 Hz, 180 Hz, 240 Hz, 300 Hz, etc. Harmonics are designated by their harmonic number, or multiple of the fundamental frequency. Thus, a harmonic with a frequency of 180 Hz (three times the 60 Hz fundamental frequency) is called the 3rd harmonic. Harmonics superimpose themselves on the fundamental waveform, distorting it and changing its magnitude. For instance, when a sine wave voltage source is applied to a non-linear load connected from a phase-leg to neutral on a 3-phase, 4-wire branch circuit, the load itself will draw a current wave made up of the 60 Hz fundamental frequency of the voltage source, plus 3rd and higher order odd harmonic (multiples of the 60 Hz fundamental frequency), which are all Selection Figure 30 — Effect of Harmonics on Current Waveform generated by the non-linear load. Total Harmonic Distortion (THD) is calculated as the square root of the sum of the squares of all harmonics divided by the normal 60 Hz value. THD= 冑 ( (( ( ( ( ( ( IRMS 60 HZ 2 IRMS 2 180 HZ IRMS 60 HZ IRMS N 2 2 Therefore, it is the percentage amount of odd harmonics (3rd, 5th, 7th ,..., 25th,...) present in the load which can affect the transformer, and this condition is called a “Non-Linear Load” or “Non-Sinusoidal Load”. To determine what amount of harmonic content is present, a K-Factor calculation is made instead of using the THD formula. The total amount of harmonics will determine the percentage of non-linear load, which can be specified with the appropriate K-Factor rating. This yields an RMS value of distortion as a percentage of the fundamental 60 Hz waveform. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-17 Technical Harmonics / K-factor Ratings Typical Symptoms of Harmonic Problems ▪ Distribution / lighting transformers overheating even when measured load current is within transformer rating ▪ Neutral cable / bus overheating even with balanced load ▪ Fuses blowing and circuit breakers tripping at currents within rating Effect Of Harmonics On Transformers Non-sinusoidal current generates extra losses and heating of transformer coils thus reducing efficiency and shortening the life expectancy of the transformer. Coil losses increase with the higher harmonic frequencies due to higher eddy current loss in the conductors. Furthermore, on a balanced linear power system, the phase currents are 120 degrees out of phase and offset one another in the neutral conductor. But with the “Triplen” harmonics (multiple of 3) the phase currents are in phase and they are additive in this neutral conductor. This may cause installations with non-linear loads to double either the size or number of neutral conductors. TECHNICAL 18 Table 17.5 K-Factor Ratings 100% NonLinear Load 50% Total KFactor Load Valve 4.0 100% 100% 13.0 K20 100% 125% 20.0 K30 100% 150% 30.0 Type Linear Load K4 K13 Selection Sizing Transformers for Non-Linear Loads ANSI / IEEE C57.110-1986 has a procedure for de-rating standard distribution transformers for non-linear loading. However this is not the only approach. A transformer with the appropriate K-Factor specifically designed for non-linear loads can be specified. K-Factors K-Factor is a ratio between the additional losses due to harmonics and the eddy losses at 60 Hz. It is used to specify transformers for non-linear loads. Note that K-Factor transformers do not eliminate harmonic distortion; they withstand the non-linear load condition without overheating. Calculating K-Factor Loads 1. List the kVA value for each load category to be supplied. Next, assign a K-factor designation that corresponds to the relative level of harmonics drawn by each type of load. Refer to Table 21.5. 2. Multiply the kVA of each load or load category times the Index of Load K-rating (ILK) that corresponds to the assigned K-factor rating. This result is an indexed kVA-ILK value. KVA x ILK = kVA-ILK. Table 17.7 Index of Load K-Ratings K-Factor K1 ILK K4 25.82 K9 44.72 K13 57.74 80.94 K30 123.54 K40 208.17 3. Tabulate the total connected load kVA for all load categories to be supplied. 4. Next, add-up the kVA-ILK values for all loads or load categories to be supplied by the transformer. 5. Divide the grand total kVA-ILK value by the total kVA load to be supplied. This will give an average ILK for that combination of loads. Total kVA-ILK/ Total kVA = average ILK. 6. From Table 21.6 find the K-factor rating whose ILK is equal to or greater than the calculated ILK. Estimating K-Factor Loads햲 K-Factor ILK Incandescent Lighting Electric Resistance Heating Motors (without solid state drives) Control Transformers / Electromagnetic Control Devices Motor-Generators (without solid state drives) Standard Distribution Transformers K1 0.00 Electric Discharge Lighting (HID) UPS with Optional Input Filter Welders Induction Heating Equipment PLCs and Solid State Controls K4 25.82 K13 57.74 Main-Frame Computer Loads Solid State Motor Drives (variable speed drives) Multiwire Receptacle Circuits in Critical Care Areas in Hospitals K20 80.94 Multiwire Receptacle Circuits in Industrial, Medical and Educational Laboratories Multiwire Receptacle Circuits in Commercial Office Spaces Small Main-Frames (mini and micro) K30 123.54 Telecommunications Equipment (PBX) UPS without Input Filtering Multiwire Receptacle Circuits in General Care Areas of Health Care Facilities, Schools, etc. Multiwire Receptacle Circuits Supplying Testing Equipment on an Assembly Line / 0.0 K20 Description Measurement of Harmonics For existing installations, the extent of the harmonics can be measured with appropriate instruments commonly referred to as “Power Harmonic Analyzers”. This service is offered by many consulting service organizations. For new construction, such information may not be obtainable. For such situations, it is best to assume the worse case condition based on experience with the type and mix of loads. 18-18 Table 17.6 Typical loads and K-Factor values for estimating purposes only. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Technical General Table 1 Ampacities of Insulated Conductors (From NEC Table 310-16) Not More Than Three Conductors in Raceway or Cable or Earth (Directly Buried). (Based on Ambient Temperature of 30°C, 86°F) Size Copper Conductors 60°C 75°C (140°F) (167°F) Types Types AWG Kcmil 0018 0016 0014 햲 0012 햲 0010 햲 0008 0006 0004 0003 0002 0001 00001⁄0 00002⁄0 00003⁄0 00004⁄0 250 300 350 400 500 600 700 750 800 900 1000 1250 1500 1750 2000 TW UF — — 020 025 030 040 055 070 085 095 110 125 145 165 195 215 240 260 280 320 355 385 400 410 435 455 495 520 545 560 RHW THW THWN XHHW USE ZW — — 020 025 035 050 065 085 100 115 130 150 175 200 230 255 285 310 335 380 420 460 475 490 520 545 590 625 650 665 90°C (194°F) Types TBS SA SIS FEP FEPB RHH THHN THHW XHHW 014 018 025 030 040 055 075 095 110 130 150 170 195 225 260 290 320 350 380 430 475 520 535 555 585 615 665 705 735 750 Aluminum Conductors Copper-Clad Aluminum Conductors 60°C 75°C 90°C (140°F) (167°F) (194°F) Types Types Types TBS, SA, SIS, THHN RHW THHW THHW THW-2, THWN-2, THW RHH, RHW-2 THWN USE-2 TW XHHW XHH, XHHW UF USE XHHW-2, ZW-2 — — — — — — — — — 햲 햲 020 020 025 햲 025 030 햲 035 햲 030 040 045 040 050 060 055 065 075 065 075 085 075 090 100 085 100 115 100 120 135 115 135 150 130 155 175 150 180 205 170 205 230 190 230 255 210 250 280 225 270 305 260 310 350 285 340 385 310 375 420 320 385 435 330 395 450 355 425 480 375 445 500 405 485 545 435 520 585 455 545 615 470 560 630 Size AWG Kcmil — — — 12 10 8 6 4 3 2 1 00001⁄0 00002⁄0 00003⁄0 00004⁄0 250 300 350 400 500 600 700 750 800 900 1000 1250 1500 1750 2000 18 Table 2 Ambient Temperature°C 21–25 26–30 31–35 36–40 41–45 46–50 51–55 56–60 61–70 71–80 For ambient temperature over 30°C, (86°F) multiply the ampacities shown above by the appropriate factor shown below. 1.08 1.05 1.04 1.08 1.05 1.04 1.00 1.00 1.00 1.00 1.00 1.00 .91 .94 .96 .91 .94 .96 .82 .88 .91 .82 .88 .91 .71 .82 .87 .71 .82 .87 .58 .75 .82 .58 .75 .82 .41 .67 .76 .41 .67 .76 0.58 .71 — 0.58 .71 — 0.33 .58 — 0.33 .58 — — — .41 — — .41 Ambient Temperature°F 70–77 78–86 87–95 96–104 105–113 114–122 123–131 132–140 141–158 159–176 햲 The load current rating and the overcurrent protection for conductor types shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-19 TECHNICAL Correction Factors for Ambient Temperature Over 30°C, 86°F Technical General Table 4A Table 4B Table 4C Motor Full-Load Currents of Three Phase AC Induction Type Motors 햲 Motor Full-Load Currents In Amperes, Single Phase, AC Motor Full-Load Currents In Amperes, DC Current in Amperes 208V 230V 460V 575V 0001⁄4 0001⁄3 0001⁄2 0003⁄4 001 0011⁄2 002 003 005 0071⁄2 010 015 020 025 030 040 050 060 075 100 125 150 200 250 300 350 400 450 500 1.11 1.34 2.4 3.5 4.6 6.6 7.5 10.6 16.7 24.2 30.8 46.2 59.4 74.8 88 114 143 169 211 273 343 396 528 —0 —0 —0 —0 —0 —0 .96 1.18 2.2 3.2 4.2 6 6.8 9.6 15.2 22.0 28.0 42.0 54 68 80 104 130 154 192 248 312 360 480 —0 —0 —0 —0 —0 —0 .48 .59 1.1 1.6 2.1 3 3.4 4.8 7.6 11.0 14.0 21.0 27 34 40 52 65 77 96 124 156 180 240 302 361 414 477 515 590 .38 .47 .9 1.3 1.7 2.4 2.7 3.9 6.1 9.0 11.0 17.0 22 27 32 41 52 62 77 99 125 144 192 242 289 336 382 412 472 TECHNICAL 18 Motor Rating Horsepower Horsepower 001⁄6 001⁄4 001⁄3 001⁄2 003⁄4 01 011⁄2 02 03 05 071⁄2 10 115V 4.4 5.8 7.2 9.8 13.8 16 20 24 34 56 80 100 230V 2.2 2.9 3.6 4.9 6.9 8 10 12 17 28 40 50 Horsepower 001⁄4 001⁄3 001⁄2 003⁄4 01 011⁄2 02 03 05 071⁄2 10 120V 3.1 4.1 5.4 7.6 9.5 13.2 17 25 40 58 76 240V 1.6 2.0 2.7 3.8 4.7 6.6 8.5 12.2 20 29 38 Table 4D Conversion Table of Polyphase Design B, C, D, and E Maximum Locked-Rotor Currents for Selection of Disconnecting Means and Controllers as Determined from Horsepower and Voltage Rating and Design Letter For use only with Sections 430-110, 440-12, 440-41, and 455-8(c) of the National Electric Code. Maximum Motor Locked-Rotor Current Amperes Two and Three Phase Design B, C, D, and E Rated 115 Volts 200 Volts 208 Volts 230 Volts HP B, C, D E B, C, D E B, C, D E B, C, D E 1 000 ⁄2 40 40 23 23 22.1 22.1 20 20 3 000 ⁄4 50 50 28.8 28.8 27.6 27.6 25 25 001 60 60 34.5 34.5 33 33 30 30 1 001 ⁄2 80 80 46 46 44 44 40 40 002 100 100 57.5 57.5 55 55 50 50 003 —0 —0 73.6 84 71 81 64 73 005 —0 —0 105.8 140 102 135 92 122 0071⁄2 —0 —0 146 210 140 202 127 183 010 —0 —0 186.3 259 179 249 162 225 015 —0 —0 267 388 257 373 232 337 020 —0 —0 334 516 321 497 290 449 025 —0 —0 420 646 404 621 365 562 030 —0 —0 500 775 481 745 435 674 040 —0 —0 667 948 641 911 580 824 050 —0 —0 834 1185 802 1139 725 1030 060 —0 —0 1001 1421 962 1367 870 1236 075 —0 —0 1248 1777 1200 1708 1085 1545 100 —0 —0 1668 2154 1603 2071 1450 1873 125 —0 —0 2087 2692 2007 2589 1815 2341 150 —0 —0 2496 3230 2400 3106 2170 2809 —0 3335 4307 3207 4141 2900 3745 200 —0 250 —0 —0 —00 —00 —00 —00 —00 —00 300 —0 —0 —00 —00 —00 —00 —00 —00 350 —0 —0 —00 —00 —00 —00 —00 —00 —0 —00 —00 —00 —00 —00 —00 400 —0 450 —0 —0 —00 —00 —00 —00 —00 —00 500 —0 —0 —00 —00 —00 —00 —00 —00 460 Volts B, C, D E 10 10 12.5 12.5 15 15 20 20 25 25 32 36.5 46 61 63.5 91.5 81 113 116 169 145 225 183 281 218 337 290 412 363 515 435 618 543 773 725 937 908 1171 1085 1405 1450 1873 1825 2344 2200 2809 2550 3277 2900 3745 3250 4214 3625 4682 575 Volts B, C, D E 8 8 10 10 12 12 16 16 20 20 25.6 29.2 36.8 48.8 50.8 73.2 64.8 90 93 135 116 180 146 225 174 270 232 330 290 412 348 494 434 618 580 749 726 936 868 1124 1160 1498 1460 1875 1760 2247 2040 2622 2320 2996 2600 3371 2900 3746 Table 5 Normal-Load and Fault Currents of Three Phase Transformers Transformer Characteristics 3-Phase 햲 Values may vary depending on manufacturer, type of motor and NEMA design. For full load currents of 200 volt motors, increase the corresponding 230 volt motor full-load current by 15 percent. Table 5 Notes: 1. Primary source available is assumed as 500 MVA at the primary of the transformer with a source circuit X/R ratio of 12. 2. Motor contribution is included in the table at twice the full-load current for 208 volt transformers and at 4 times the full-load current for 240 volt and 480 volt transformers. These values are derived from the assumption that 208 volt systems are 50% motor load and 240 and 480 volt systems are 100% motor load. 3. All short circuit current values are in symmetrical RMS amperes. 18-20 kVA Rating 112.5 150 225 300 500 750 1000 1500 2000 2500 1000 1500 AC Voltage 3-Phase 280V Normal Load Short % Continuous Circuit Impedance Amperes Current 2.25 312 14,491 3.00 416 14,699 4.50 625 15,139 5.00 834 18,326 5.00 1388 30,536 5.75 2080 40,373 5.75 2780 53,830 5.75 4162 80,745 —0 0 0 5.75 —00 5.75 —00 —0 0 0 8.00 —00 —0 0 0 8.00 —00 —0 0 0 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 240V Normal Load Continuous Amperes 271 361 541 722 1203 1804 2406 3610 4812 6010 —00 —00 Short Circuit Current 13,128 13,477 14,186 17,328 28,872 38,590 51,467 77,201 102,914 128,647 —0000 —0000 480V Normal Load Continuous Amperes 135 180 271 361 601 902 1203 1805 2406 3008 1203 1805 Short Circuit Current 6,540 6,720 7,106 8,664 14,424 19,295 25,734 38,590 51,467 64,324 19,850 29,766 Technical General Table 6 Electrical Formulas for Finding Amperes, Horsepower, Kilowatts and kVA To Find Kilowatts kVA Horsepower (Output) Amperes when Horsepower is Known Amperes when Kilowatts is Known Amperes when kVA is Known Single Phase I x E x pf 1000 IxE 1000 I x E x % EFF x pf 746 Alternating Current Two Phase 햲, Four Wire I x E x 2 x pf 1000 IxEx2 1000 I x E x 2 x % EFF x pf 746 Three Phase I x E x 1.73 x pf 1000 I x E x 1.73 1000 I x E x 1.73 x % EFF x pf 746 Direct Current IxE 1000 I x E x % EFF 746 HP x 746 E x % EFF x pf HP x 746 2 x E x % EFF x pf HP x 746 1.73 x E x % EFF x pf HP x 746 E x % EFF KW x 1000 E x pf KW x 1000 2 x E x pf KW x 1000 1.73 x E x pf KW x 1000 E kVA x 1000 E kVA x 1000 2xE kVA x 1000 1.73 x E Average Efficiency and Power Factor Values of Motors When the actual efficiencies and power factors of the motors to be controlled are not known, the following approximations may be used. Efficiencies: DC motors, 35 horsepower and less 80% to 85% DC motors, above 35 horsepower 85% to 90% Synchronous motors (at 100% power factor) 92% to 95% “Apparent” Efficiencies ( = Efficiency x Power Factor); Three phase induction motors, 25 horsepower and less 70% Three phase induction motors above 25 horsepower 80% These figures may be decreased slightly for single phase and two phase induction motors. Fault-Current Calculation on LowVoltage AC Systems In order to determine the maximum interrupting rate of the circuit breakers in a distribution system it is necessary to calculate the current which could flow under a three phase bolted short circuit condition. For a three phase system the maximum available fault current at the secondary side of the transformer can be obtained by use of the formula: ISC = kVA x 100 KV x √3 x % Z Minimum Size Grounding Conductors for Grounding Raceways and Equipment (From NEC Table 250–122) Size Copper Wire Number 14 12 10 10 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 kcmil 350 kcmil 400 kcmil 500 kcmil 700 kcmil 800 kcmil Aluminum or Copper Clad Aluminum Wire Number 12 10 8 8 8 6 4 2 1 1/0 2/0 3/0 4/0 250 kcmil 350 kcmil 400 kcmil 600 kcmil 600 kcmil 800 kcmil 1200 kcmil 1200 kcmil Note: Where necessary to comply with 250.4(A)(5) or (B)(4), the equipment grounding conductor shall be sized larger than given in this table. Table 7 햳 Grounding Electrode Conductor for AC Systems (From NEC Table 250–66) Size of Largest Service Entrance Conductor or Equivalent Area for Parallel Conductors Copper 2 or smaller 1 or 1/0 2/0 or 3/0 Over 3/0 to 350 kcmil Over 350 kcmil to 600 kcmil Over 600 kcmil to 1100 kcmil Over 1100 kcmil Aluminum or Copper Clad Aluminum 1/0 or smaller 2/0 or 3/0 4/0 or 250 kcmil Over 250 kcmil to 500 kcmil Over 500 kcmil to 900 kcmil Over 900 kcmil to 1750 kcmil Over 1750 kcmil 햲 In three wire, two phase circuits the current in the common conductor is 1.41 times that in either other conductor. E = Volts I = Amperes % EFF = Per Cent Efficiency Size of Grounding Electrode Conductor Aluminum or Copper Clad Copper Aluminum 8 6 6 4 4 2 2 1/0 1/0 3/0 2/0 4/0 3/0 250 kcmil 햳 Additional information and exceptions are stated in Article 250 — Grounding, National Electric Code. pf = Power Factor Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-21 TECHNICAL Rating or Setting of Automatic Overcurrent Device in Circuit Ahead of Equipment, Conduit etc., Not Exceeding (Amperes) 15 20 30 40 60 100 200 300 400 500 600 800 1000 1200 1600 2000 2500 3000 4000 5000 6000 18 where: ISC = Symmetrical RMS amperes of fault current. kVA = Kilovolt-ampere rating of transformers. KV = Secondary voltage in kilovolts. % Z = Percent impedance of primary line and transformer. Table 5 on page 18-20 has been prepared to list the symmetrical RMS fault current which is available at the secondary terminals of the transformer. Table 8 햳 Molded Case Circuit Breakers Unusual Operating Conditions Application Note: The information provided on this and the next page is intended for reference and recommendation only. Because several variables can act on a circuit breaker’s performance at the same time, the data below is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. TECHNICAL 18 High Ambient Temperatures Because standard thermal-magnetic breakers are temperature sensitive and calibrated for a specific ambient of 40°C (104°F) (average enclosure temperature), the presence of an ambient higher will cause the breaker to carry less current than its name-plate rating — in other words, causing the breaker to “derate” (see Table 17.33). Similarly, the safe current carrying capacity of a circuit conductor is based upon an ambient temperature of 30°C (86°F) (average air temperature) and the presence of a higher ambient will reduce its safe current carrying capacity, causing it to “derate.” Thus, it can be seen from Table 17.33 that in the presence of a fluctuating temperature, a thermal-magnetic breaker will derate nearly parallel with its connected circuit conductors and maintain close circuit protection. If the application temperature exceeds 40°C (104°F) and is known, either a breaker especially calibrated for the higher ambients or one oversized according to Table 17.33 may be selected. It should be noted that in a case such as this, the circuit conductors should be oversized as well. Siemens Sensitrip® III and Type SB Encased System Breakers are insensitive to temperature changes. However, they do include circuitry to protect the components from abnormally high temperatures. Table 17.35 Reference Ampere Rating at 40°C (104°F) 15 20 25 30 35 40 50 60 70 90 100 125 150 175 200 225 250 300 350 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 Temperature Derating Data for Thermal-Magnetic Breakers Relative Amperage Rating at: 25°C (77°F) 17 22 28 33 39 44 55 66 77 99 110 137 165 192 220 247 275 330 385 440 550 660 770 880 990 1100 1320 1540 1760 1980 2200 50°C (122°F) 13 18 23 28 30 37 46 56 65 84 94 144 136 159 182 205 235 276 325 372 468 564 658 754 828 900 1090 1304 1500 1690 1880 60°C (140°F) 11 16 21 26 25 34 42 52 60 78 87 100 120 140 160 180 220 252 301 340 435 525 613 704 749 825 1000 1148 1320 1485 1650 Moisture — Corrosion For atmospheres having high moisture content and I or where fungus growth is prevalent, a special preventive treatment may be required. Where the air is heavily laden with corrosive elements, breakers made with special corrosion-resistant finishes are recommended. Altitude Reduced air density at altitudes greater than 6600 ft. (2000 meters) affects the ability for a molded case circuit breaker to transfer heat and interrupt faults. Therefore, circuit breakers applied at these altitudes should have interrupting insulation and continuous currents derated as indicated in Table 17.34. Table 17.34 Altitude Correction Rating Correction Factor Continuous Altitude in feet (meters) Current Voltage 6600 (and below) (2000) 1 1 8500 (2600) 0.95 0.99 13000 (4000) 0.8 0.96 햲 Values for intermediate altitudes may be derived from linear interpolation. See Figure 1. 18-22 Figure 1 — Altitude Adjustment Chart Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Siemens Beaker Types ED2 ED4 ED6 HED4 HED6 CED6 FXD6 FD6 HFD6 CFD6 QJ2 QJH2 QJ2-H JXD2 MXD6, MD6 HMXD6 HMD6 CMD6 JXD6 JD6 HJD6 HHJD6 CJD6 NXD6, ND6 HNXD6 HND6 CND6 LXD6 LD6 HLD6 HHLD6 CLD6 PXD6, PD6 HPXD6, HPD6 CPD6 RXD6, RD6 HRXD6, HRD6 Molded Case Circuit Breakers Unusual Operating Conditions (400 Hz Systems햲) Circuit Breaker Derating Required Table 17.35 lists the maximum continuous current carrying capacity for Siemens breakers at 400 Hz. Due to the increased resistance of the copper sections resulting from the skin effect produced by eddy currents at these frequencies, circuit breakers In many cases require derating. The thermal derating on these devices is based upon 100%, three phase application in open air in a maximum of 40°C (104°F) with 48 in. (1219 mm) of the specified cable (75°C) of bus at the line and load side. Additional derating of not less than 20% will be required if the circuit breaker is to be utilized in an enclosure. Further derating may be required if the enclosure contains other heat generating devices or if the ambient temperatures exceed 40°C (104°F). Cable and Bus Sizing The cable and bus sizes to be utilized at 400 Hz are not based on standard Table 17.36 National Electric Codes tables for 60 Hz application. Larger cross sections are necessary at 400 Hz to avoid exceeding component temperature limits. All bus bars specified are based upon mounting the bars in the vertical plane to allow maximum air flow. All bus bars are spaced at a minimum of 0.25 in. (6 mm) apart. Mounting of bus bars in the horizontal plane will necessitate additional drafting. Edgewise orientation of the bus may change the maximum ratings indicated. If additional information is required for other connections of cable or bus, contact Siemens for information. Application Recommendations It is recommended that thermal indicating devices be placed on the line and load terminals or T-connectors of the center pole. These are usually the hottest terminals with a balanced load. A maximum temperature of 75°C (35°C over a maximum ambient of 40°C) would Application verify the maximum rating for the particular application. Temperature profiles taken on these breakers can be correlated to ensure that the hottest points within the breaker are within the required temperature limits. Factory Configurations When required, molded case circuit breakers may be factory calibrated for 400 Hz application. These breakers are specially labeled for 400 Hz usage and their nameplate current rating will include the necessary derating factor. The highest “Maximum Continuous Amperes” rating at 400 Hz, found in Table 17.35 approximately equals the highest specially calibrated 400 Hz nameplate ampere rating available for a given frame size. Contact Siemens for ordering information on other breakers applied in 400 Hz systems. 400 Hz Breakers Maximum Continuous Ampere Rating At 40°C (104°F) 햳 60 Hz 400 Hz Siemens Breaker Enclosed Type Open Air Open Air 햴 After Derating 250 210 168 LD2, LXD6, HLD6, HLXD6, 300 240 192 HHLD6, 350 260 208 HHLXD6, 400 300 240 CLD6 450 340 272 500 375 300 600 420 336 250 210 210 LD6, LXD6, HLD6, HLXD6 300 240 240 100% Rated 350 260 260 400 300 300 450 340 340 500 375 375 600 420 420 500 400 320 MD6, MXD6, HMD6, HMXD6, 600 430 360 CMD6 700 500 400 800 560 448 500 400 400 MD6, MXD6, HMD6, HMXD6, 600 430 430 CMD6 700 500 500 100% Rated 800 560 560 800 560 448 ND6, NXD6, HND6, HNXD6, 900 600 480 CND6 1000 650 520 1200 780 624 900 600 600 ND6, NXD6, HND6, HNXD6, 1000 650 650 CND6 1200 780 780 780 624 PD6,PXD6,HPD6 1200 HPXD6, CPD6 1400 850 680 100% Rated 1600 960 768 1200 780 780 PD6, PXD6, HPD6, HPXD6 1400 850 850 CPD6 1600 960 960 1600 960 768 RD6, RXD6, 1800 1080 864 HRD6, HRXD6 80% Rated 2000 1200 960 75°C (167°F) Copper Cable per Pole No. of Wire Pieces Size 1 pc. 250 kcmil 1 pc. 350 kcmil 1 pc. 500 kcmil 2 pcs. #3/0 2 pcs. #4/0 2 pcs. 250 kcmil 350 kcmil 2 pcs. 1 pc. 250 kcmil 350 kcmil 1 pc. 500 kcmil 1 pc. 2 pcs. #3/0 2 pcs. #4/0 2 pcs. 250 kcmil 2 pcs. 350 kcmil 2 pcs. 250 kcmil 2 pcs. 350 kcmil 3 pcs. 250 kcmil 3 pcs. 300 kcmil 2 pcs. 250 kcmil 2 pcs. 350 kcmil 3 pcs. 250 kcmil 3 pcs. 300 kcmil 3 pcs. 300 kcmil 3 pcs. 350 kcmil 3 pcs. 400 kcmil 4 pcs. 350 kcmil 3 pcs. 350 kcmil 3 pcs. 400 kcmil 4 pcs. 350 kcmil 4 pcs. 400 kcmil 4 pcs. 500 kcmil 5 pcs. 500 kcmil 4 pcs. 400 kcmil 4 pcs. 500 kcmil 5 pcs. 500 kcmil 5 pcs. 500 kcmil 5 pcs. 500 kcmil 6 pcs. 500 kcmil 햲 The information provided on this page is intended for reference and recommendation only. Because several variables can act on a circuit breaker’s performance atthe same time, the data above is based less on controlled testing than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. 햳 Additional derating may be required if the ambient temperature is greater than 40°C (104°F). 햴 Calculated after derating to compensate for the heating of the copper conductor, caused by the skin effect generated by eddy currents produced at 400/415 Hz. Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-23 TECHNICAL 75°C (167°F) Copper Cable per Pole No. of Wire Pieces Size 1 pc. #14 1 pc. #12 1 pc. #10 1 pc. #10 1 pc. #10 1 pc. #8 1 pc. #8 1 pc. #8 1 pc. #6 1 pc. #4 1 pc. #4 1 pc. #3 1 pc. #3 1 pc. #2 1 pc. #1 1 pc. #4 1 pc. #4 1 pc. #3 1 pc. #3 1 pc. #2 1 pc. #1 1 pc. #1/0 1 pc. #2/0 1 pc. #3/0 1 pc. #4/0 1 pc. 250 kcmil 1 pc. #3/0 1 pc. #4/0 1 pc. 250 kcmil 1 pc. 350 kcmil 1 pc. 500 kcmil 2 pcs. #3/0 2 pcs. #3/0 2 pcs. #4/0 1 pc. 250 kcmil 1 pc. 350 kcmil 1 pc. 500 kcmil 2 pcs. #3/0 18 Maximum Continuous Ampere Rating At 40°C (104°F) 햳 60 Hz 400 Hz Siemens Breaker Enclosed Type Open Air Open Air 햴 After Derating 15 15 12 ED2, ED4, ED6, HED4, 20 20 16 HED6, CED6 25 25 20 30 30 24 35 35 28 40 40 32 45 43 34 50 48 38 60 57 46 60 67 54 80 76 61 90 86 69 100 95 76 110 105 84 125 119 95 70 63 50 FD6, FXD4, HFD6, HFXD4, 80 72 58 CFD6 90 80 64 100 90 72 110 95 75 125 105 84 150 125 100 175 140 112 200 160 128 225 180 144 250 200 160 200 170 136 JXD2, JD6, JXD6, HJD6, 225 190 152 HJXD6, HHJD6, 250 210 168 HHJXD6, CJD6 300 240 192 350 260 208 400 300 240 200 170 170 JD6, JXD6, HJD6, HJXD6, 225 190 190 100% Rated 250 210 210 300 240 240 350 260 260 400 300 300 Molded Case Circuit Breakers Capacitor Circuit Conductors TECHNICAL 18 Article 460-8 (N.E.C.) The ampacity of capacitor circuit conductors shall not be less than 135% of the rated current of the capacitor. The ampacity of conductors that connect a capacitor to the terminals of a motor or to motor circuit conductors shall not be less than one-third the ampacity of the motor circuit conductors and in no case less than 135% of the rated current of the capacitor. Application Circuit breakers and switches for use with capacitors must have a current rating in excess of rated capacitor current to provide for overcurrent from overvoltages at fundamental frequency and harmonic currents. Use the following percent of capacitor current rating to size circuit breaker or fused and non-fused switches. 150% ▪ Enclosed Circuit Breakers (Includes derating factor for enclosure) 165% ▪ Fused and non-fused switches Due to switching surges, and possible overcurrent related to overvoltage and harmonics, Siemens recommends using 150% of the capacitor current rating to size a thermal-magnetic circuit breaker for overload protection. If the circuit breaker is to be applied in an ambient greater than the marked rated ambient, it may be necessary to derate the continuous current rating. This is also true for applications where harmonic components are present. A basic formula to use for calculation of the capacitor current rating is as follows (assuming three phase application): Capacitor (Kvar) x 1000 (Voltage / 1.732) x 3 The interrupting rating of the circuit breaker or fuse must be selected to match the system fault current available at the point of the capacitor application. 18-24 Application Table 17.37 Capacitor Application Capacitor Rating Voltage 240 480 Amperage K var 2.5 5 7.5 10 15 20 25 30 45 50 60 75 90 100 120 125 135 150 180 200 225 240 250 270 300 360 375 2 5 7.5 10 15 20 25 30 35 40 45 50 60 75 80 90 100 Capacitor Rating 6 12 18 24.1 36.1 48.1 60 72.2 108 120 144 180 217 240 289 301 325 361 433 480 541 578 602 650 720 866 903 2.41 6 9 12 18 24 30 36.1 42.1 48.1 54.1 60.1 72.2 90.2 96.2 108.3 120.3 Enclosed Switch Fuse Rating 15 20 30 40 60 80 100 125 200 200 250 300 400 400 500 500 600 600 800 800 900 1000 1000 1200 1200 1600 1600 15 15 15 20 30 40 50 60 70 80 90 100 125 150 175 200 200 120 144 250 MCCB Trip Rating 15 20 30 40 60 80 90 125 175 200 225 275 350 400 450 450 500 500 700 800 900 900 900 1000 1200 1400 1400 15 15 15 20 30 40 50 50 60 70 80 100 110 150 150 175 200 225 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Capacitor Rating Amperage Voltage K var Capacitor Rating Enclosed Switch Fuse Rating MCCB Trip Rating 125 150 250 225 150 180 300 300 160 192 350 300 180 216 400 350 200 241 400 400 225 271 500 500 240 250 289 301 500 500 500 500 300 320 360 375 400 361 385 433 451 481 600 700 800 800 800 600 600 700 700 800 450 5 7.5 10 15 20 25 30 35 40 45 50 60 75 80 100 120 125 150 160 180 200 225 240 250 300 320 360 375 400 450 541 4.8 7.2 9.6 14.4 19.2 24.1 28.9 33.7 38.5 43.3 48.1 57.7 72.2 77 96.2 115 120 144 154 173 192 217 231 241 289 308 346 361 385 433 900 15 15 20 25 35 40 50 60 70 80 80 100 125 150 175 200 200 250 300 300 300 400 400 400 500 600 600 600 700 800 900 15 15 15 30 30 40 50 50 70 70 100 100 125 125 150 175 200 225 250 300 300 350 350 400 450 500 600 600 600 700 480 (cont’d) 600 Technical Fraction, Decimal, and Millimeter Equivalents Fractions to Decimals to Millimeters Millimeters to Millimeters 0.397 0.794 1.191 1.588 1.984 2.381 2.778 3.175 3.572 3.969 4.366 4.763 5.159 5.556 5.953 6.350 6.747 7.144 7.541 7.938 8.334 8.731 9.128 9.525 9.922 10.319 10.716 11.113 11.509 11.906 12.303 12.700 13.097 13.494 13.891 14.288 14.684 15.081 15.478 15.875 16.272 16.669 17.066 17.463 17.859 18.256 18.653 19.050 19.447 19.844 20.241 20.638 21.034 21.431 21.828 22.225 22.622 23.019 23.416 23.813 24.209 24.606 25.003 25.400 Millimeters 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Inches 0.0039 0.0079 0.0118 0.0157 0.0197 0.0236 0.0276 0.0315 0.0354 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 0.0394 0.0787 0.1181 0.1575 0.1969 0.2362 0.2756 0.3150 0.3543 0.3937 0.4331 0.4724 0.5118 0.5512 0.5906 0.6299 0.6693 0.7087 0.7480 0.7874 0.8268 0.8661 0.9055 0.9449 0.9843 1.0236 1.0630 1.1024 1.1417 1.1811 1.2205 1.2598 1.2992 1.3386 1.3780 1.4173 1.4567 1.4961 1.5354 1.5748 1.6142 1.6535 1.6929 1.7323 1.7717 Millimeters 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Inches 1.8110 1.8504 1.8898 1.9291 1.9685 2.0079 2.0472 2.0866 2.1260 2.1654 2.2047 2.2441 2.2835 2.3228 2.3622 2.4016 2.4409 2.4803 2.5197 2.5591 2.5984 2.6378 2.6772 2.7165 2.7559 2.7953 2.8346 2.8740 2.9134 2.9528 2.9921 3.0315 3.0709 3.1102 3.1496 3.1890 3.2283 3.2677 3.3071 3.3465 3.3858 3.4252 3.4646 3.5039 3.5433 3.5827 3.6220 3.6614 3.7008 3.7402 3.7795 3.8189 3.8583 3.8976 3.9370 TECHNICAL Decimals 0.015625 0.03125 0.046875 0.0625 0.078125 0.09375 0.109375 0.1250 0.140625 0.15625 0.171875 0.1875 0.203125 0.21875 0.234375 0.2500 0.265625 0.28125 0.296875 0.3125 0.328125 0.34375 0.359375 0.3750 0.390625 0.40625 0.421875 0.4375 0.453125 0.46875 0.484375 0.500 0.515625 0.53125 0.546875 0.5625 0.578125 0.59375 0.609375 0.6250 0.640625 0.65625 0.671875 0.6875 0.703125 0.71875 0.734375 0.7500 0.765625 0.78125 0.796875 0.8125 0.828125 0.84375 0.859375 0.8750 0.890625 0.90625 0.921875 0.9375 0.953125 0.96875 0.984375 1.000 18 Fractions 1/64 1/32 3/64 1/16 5/64 3/32 7/64 1/8 9/64 5/32 11/64 3/16 13/64 7/32 15/64 1/4 17/64 9/32 19/64 5/16 21/64 11/32 23/64 3/8 25/64 13/32 27/64 7/16 29/64 15/32 31/64 1/2 33/64 17/32 35/64 9/16 37/64 19/32 39/64 5/8 41/64 21/32 43/64 11/16 45/64 23/32 47/64 3/4 49/64 25/32 51/64 13/16 53/64 27/32 55/64 7/8 57/64 29/32 59/64 15/16 61/64 31/32 63/64 1 Conversion Tables Inches 햲 햲 0.001" = 0.0254 mm 1 mm = 0.03937" Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 18-25 TECHNICAL 18 NOTES 18-26 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Product Index Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page A01ED62 A01ED62B A01EDLV A01FD62 A01FD64 A01FDLV A01HCPL4 A01HCPR4 A01JLD64 A01JLD64 MCCB MCCB MCCB MCCB MCCB MCCB VBSS VBSS MCCB MCCB 6-36 6-36 6-36 6-39 6-39 6-39 4-22 4-22 6-43 6-47 ASKL2 ASKL3 ASKL3 ASKL3 ASKL3 ASKP3 ASKP3 ASKP3 ASKP4 ASKP4 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-99 6-103 6-107 6-111 6-99 6-115 6-119 6-122 6-115 6-119 B215HH B215HID B215R B220 B220AF B220AFH B220H B220HH B220HID B220R MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-20 6-18 6-18 6-19 6-19 6-18 6-18 6-20 6-18 B38 B38 B38 B38 B38 B38 B380 B380H B380HH B390 UNPB UNPB UNPB UNPB UNPB UNPB MCCB MCCB MCCB MCCB 10-10 10-10 10-10 10-10 10-10 10-10 6-18 6-18 6-18 6-18 BE240H BE250 BE250H BE260 BE260H BE4 BEC3100 BEC4100 BF115 BF115H MCCB 6-19 MCCB 6-19 MCCB 6-19 MCCB 6-19 MCCB 6-19 RESG 2-81 BPLU 14-57 BPLU 14-57 MCCB 6-19 MCCB 6-19 A01JLD64 A01JLD64B A01JLD64B A01JLD64B A01JLDLV A01JLDLV A01JLDLV A01MN64 A01MN64 A01MN64 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-50 6-43 6-47 6-50 6-43 6-47 6-50 6-54 6-58 6-61 ASKP4 ASWPA ASWPA ASWPA ASWPA ASWPA ASWPA ASWPA ASWPB ASWPB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-122 6-103 6-107 6-111 6-115 6-119 6-122 6-99 6-103 6-107 B225 B225H B225HH B230 B230H B230HH B230HID B230R B230S B235 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-20 6-18 6-20 6-18 B390H B390HH B44 B44 B44 B44 B44 B44 B56 B56 MCCB MCCB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB 6-18 6-18 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 BF120 BF120H BF125 BF125H BF130 BF130H BF215 BF215H BF220 BF220H MCCB MCCB MCCB A01MN64 A01MN64B A01MN64B A01MN64B A01MN64B A01MNDLV A01MNDLV A01MNDLV A01MNDLV A02ED62 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-63 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 6-36 ASWPB ASWPB ASWPB ASWPB ASWPB B00ED62 B00ED64 B00FD64 B00MN64 B00MN64 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-111 6-115 6-119 6-122 6-99 6-36 6-36 6-39 6-54 6-58 B235H B235HH B240 B240H B240HH B240R B245 B245H B245HH B250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 B56 B56 B56 B56 B62 B62 B62 B62 B62 B62 UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 BF230 BF230H BF240 BF240H BF250 BF250H BF260 BF260H BFC3250 BFC4250 MCCB 6-19 MCCB 6-19 MCCB 6-19 MCCB 6-19 MCCB 6-19 MCCB 6-19 MCCB 6-19 MCCB 6-19 BPLU 14-57 BPLU 14-57 A02ED62B A02FD62 A02FD64 A02JLD64 A02JLD64 A02JLD64 A02JLD64B A02JLD64B A02JLD64B A02JLDLV MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-36 6-39 6-39 6-43 6-47 6-50 6-43 6-47 6-50 6-43 B00MN64 B00MN64 B01JLD64 B01JLD64 B01JLD64 B110 B115 B115AF B115AFH B115H MCCB MCCB MCCB MCCB MCCB 6-61 6-63 6-43 6-47 6-50 6-18 6-18 6-19 6-19 6-18 B250H B250HH B250R B260 B260H B260HH B260R B260S B270 B270H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-20 6-18 6-18 B68 B68 B68 B68 B68 B68 BBKB32 BBKB32 BBKEB32 BBKED32 UNPB UNPB UNPB UNPB UNPB UNPB PBSB PBSB PBSB PBSB 10-10 10-10 10-10 10-10 10-10 10-10 10-31 10-42 10-42 10-31 BG215 BG220 BG230 BG315 BG320 BG330 BHP BJC3400 BJC4400 BK1 MCCB 6-20 MCCB 6-20 MCCB 6-20 MCCB 6-20 MCCB 6-20 MCCB 6-20 PILO 16-187 BPLU 14-57 14-57 UNPB 10-11 A02JLDLV A02JLDLV A02MN64 A02MN64 A02MN64 A02MN64 A02MN64B A02MN64B A02MN64B A02MN64B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-47 6-50 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 B115HH B115HID B115T B120 B120AF B120AFH B120H B120HH B120HID B120T MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-20 6-20 6-18 6-19 6-19 6-18 6-18 6-20 6-20 B270HH B270R B280 B280H B280HH B280R B290 B290H B290HH B290R MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 BBKED32 BBKNB32 BBKNB32 BBKQ1 BBKQ2 BCT1036HND6 BCT1036NXD6 BCT1236HND6 BCT1236NXD6 BCT331 PBSB PBSB PBSB PBSB PBSB SWBD SWBD SWBD SWBD BUSW 10-42 10-31 10-42 10-31 10-42 12-24 12-24 12-24 12-24 14-61 BK2 BK3 BLC3600 BLC4600 BMC3800 BMC4800 BNK2 BOS14321 BOS14322 BOS14323 UNPB 10-11 10-11 BPLU 14-57 14-57 BPLU 14-57 14-57 PBSB 10-31 BPLU 14-57 BPLU 14-57 BPLU 14-57 A02MNDLV A02MNDLV A02MNDLV A02MNDLV ACT331 AMBL1 AMBL1 AMBL1 AMBL1 AMBL2 MCCB MCCB MCCB MCCB BUSW MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 14-61 6-103 6-107 6-111 6-99 6-103 B125 B125H B125HH B130 B130H B130HH B130HID B135 B135H B135HH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-20 6-18 6-18 6-18 B310 B3100 B3100H B3100HH B315 B315H B315HH B32 B32 B32 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 UNPB 10-10 UNPB 10-10 UNPB 10-10 BCT436HJD6 BCT436JXD6 BCT636HLD6 BCT636LXD6 BCT836HMD6 BCT836MXD6 BDH10 BDH10 BDH10 BDH10 SWBD SWBD SWBD SWBD SWBD SWBD BUSW BUSW BUSW BUSW 12-24 12-24 12-24 12-24 12-24 12-24 14-51 14-51 14-51 14-51 BOS14324 BOS14325 BOS14326 BOS14351 BOS14352 BOS14353 BOS14354 BOS14355 BOS14356 BOS16421 BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU AMBL2 AMBL2 AMBL2 AMBL3 AMBL3 AMBL3 AMBL3 AMBP1 AMBP1 AMBP1 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-107 6-111 6-99 6-103 6-107 6-111 6-99 6-115 6-119 6-122 B140 B140H B140HH B145 B145H B145HH B150 B150H B150HH B160 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 B32 B32 B32 B320 B320H B320HH B325 B325H B325HH B330 UNPB 10-10 UNPB 10-10 UNPB 10-10 MCCB 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 MCCB 6-18 BDH10 BDH12 BDH12 BDH12 BDP302 BDP304 BDP306 BDP308 BDP310 BDP313 BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW 14-51 14-51 14-51 14-51 14-50 14-50 14-50 14-50 14-50 14-50 BOS16422 BOS16423 BOS16424 BOS16425 BOS16426 BOS16451 BOS16452 BOS16453 BOS16454 BOS16455 BPLU 14-57 BPLU 14-57 BPLU 14-57 14-57 14-57 BPLU 14-57 BPLU 14-57 BPLU 14-57 BPLU 14-57 14-57 6-115 6-119 6-122 6-25 6-33 6-25 6-33 6-25 6-33 6-25 B160H B160HH B170 B170H B170HH B210 B2100 B2100H B2100HH B2100HH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 B330H B330HH B335 B335H B335HH B340 B340H B340HH B345 B345H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 BDP316 BDP4024 BDP4044 BDP4064 BDP4084 BDP4104 BE1 BE115 BE115H BE120 BUSW BUSW BUSW BUSW BUSW BUSW RESG MCCB MCCB MCCB 14-50 14-50 14-50 14-50 14-50 14-50 2-81 6-19 6-19 6-19 BOS16456 BQ1B010 BQ1B010QLD BQ1B010QXD BQ1B015 BQ1B015H BQ1B015QLD BQ1B015QXD BQ1B020 BQ1B020H BPLU 14-57 6-26 6-27 6-27 MCCB 6-26 MCCB 6-26 MCCB 6-27 MCCB 6-27 MCCB 6-26 MCCB 6-26 6-33 6-25 6-33 6-103 6-107 6-111 6-99 6-103 6-107 6-111 B2100R B2110 B2110H B2125 B2125H B2125HH B215 B215AF B215AFH B215H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-19 6-19 6-18 B345HH B350 B350H B350HH B360 B360H B360HH B370 B370H B370HH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 6-18 BE120H BE130 BE130H BE215 BE215H BE220 BE220H BE230 BE230H BE240 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-19 6-19 6-19 6-19 6-19 6-19 6-19 6-19 6-19 6-19 BQ1B020QLD BQ1B020QXD BQ1B025 BQ1B025H BQ1B025QLD BQ1B025QXD BQ1B030 BQ1B030H BQ1B030QLD BQ1B030QXD MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MCCB 6-27 6-27 6-26 6-26 6-27 6-27 6-26 6-26 6-27 6-27 19-1 PRODUCT INDEX ASKE5 ASKE6 ASKE6 ASKL1 ASKL1 ASKL1 ASKL1 ASKL2 ASKL2 ASKL2 MCCB MCCB MCCB MCCB MCCB MCCB 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 19 AMBP2 AMBP2 AMBP2 ASKE1 ASKE1 ASKE2 ASKE2 ASKE3 ASKE3 ASKE5 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-19 6-19 6-19 6-19 6-19 6-19 6-19 6-19 6-19 6-19 Product Index Catalog Number PRODUCT INDEX 19 BQ1B035 BQ1B035H BQ1B035QLD BQ1B035QXD BQ1B040 BQ1B040H BQ1B040QLD BQ1B040QXD BQ1B045 BQ1B045H Product Category MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page 6-26 6-26 6-27 6-27 6-26 6-26 6-27 6-27 6-26 6-26 BQ3B025 BQ3B025H BQ3B030 BQ3B030H BQ3B035 BQ3B035H BQ3B040 BQ3B040H BQ3B045 BQ3B045H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 BQD6350 BQD6360 BQD6370 BQDA1 BQDA1BA BQDA2 BQDBA BQDHBD BQDPLD BQDST12 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-86 6-86 6-21 C1C42ML250CTS C1C42QJ225CTS C2E18BD100CTS C2E18E4125CTS C2E18FX225CTS C2E18FX250CTS C2E18ML125CTS C2E18ML250CTS C2E30BD100CTS C2E30E4125CTS 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 CDT4B060 CDT4B070 CDT4B080 CDT4B090 CDT4B100 CDT4B110 CDT4B125 CDT4B150 CED62B015 CED62B020 MCCB MCCB 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-35 6-35 6-27 6-27 6-26 6-26 6-27 6-27 6-26 6-26 6-27 6-27 BQ3B050 BQ3B050H BQ3B060 BQ3B060H BQ3B070 BQ3B070H BQ3B080 BQ3B080H BQ3B090 BQ3B090H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 BQDST120 BQDST120AAS BQDST125 BQDST125DAS BQDST12DAS BQDST24 BQDST24 BQDST240 BQDST240AAS BQDST24AAS MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 C2E30FX225CTS C2E30FX250CTS C2E30ML125CTS C2E30ML250CTS C2E42BD100CTS C2E42E4125CTS C2E42FX225CTS C2E42FX250CTS C2E42ML125CTS C2E42ML250CTS 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 CED62B030 CED62B040 CED62B050 CED62B060 CED62B070 CED62B080 CED62B090 CED62B100 CED62B125 CED62S100A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-72 BQ3B100 BQ3B100H BQ3S060 BQ3S100 BQD1100 BQD115 BQD120 BQD125 BQD130 BQD135 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-26 6-26 6-72 6-72 6-21 6-21 6-21 6-21 6-21 6-21 BQDST24DAS BQDST277 BQDST277AAS BQDST48 BQDST480 BQDST480AAS BQDST48DAS BQDST600 BQDST600AAS BQFS1K MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-27 CBCF18 CBCF18 CBCM36 CBCM36 CBCM36 CBCM36 CBCM36 CBCP54 CBCP54 CBCP54 6-136 6-136 6-136 6-136 6-137 6-137 6-137 6-136 6-136 6-137 CED62S125A CED63A001 CED63A001 CED63A003 CED63A005 CED63A010 CED63A025 CED63A030 CED63A040 CED63A050 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-72 6-66 6-66 6-66 6-66 6-66 6-66 6-66 6-66 6-66 MCCB MCCB MCCB MCCB 6-27 6-87 6-87 6-87 6-138 6-138 6-138 6-138 6-138 6-138 CBCP54 CBCP54 CBCP54 CBCP54 CBTF CBTF CBTL CBTL CBTM CBTP 6-137 6-137 6-137 6-137 6-136 6-136 6-137 6-137 6-137 6-137 CED63A100 CED63A125 CED63B015 CED63B020 CED63B030 CED63B040 CED63B050 CED63B060 CED63B070 CED63B080 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-66 6-66 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-139 6-139 6-139 6-139 6-139 6-139 6-139 6-139 6-139 6-139 CBTP CCE125 CCF250 CCF250 CCL600 CCL600 CCL600 CCL600 CCM800K2 CCM800K3 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-137 6-83 6-37 6-83 6-40 6-42 6-44 6-83 6-83 6-83 CED63B090 CED63B100 CED63B110 CED63B125 CED63S100A CED63S125A CED6N12 CED6N12 CED6N1F CED6N1F MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-72 6-72 5-13 6-34 5-8 6-34 CCN1200K2 CCN1200K3 CCQ225 CDT2B050 CDT2B060 CDT2B070 CDT2B080 CDT2B090 CDT2B100 CDT2B110 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-83 6-83 6-83 6-97 6-97 6-97 6-97 6-97 6-97 6-97 CED6N1S CED6N1S CED6N3R CED6N3R CFD63A150 CFD63A250 CFD63B070 CFD63B080 CFD63B090 CFD63B100 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 5-8 6-34 5-10 6-34 6-66 6-66 6-38 6-38 6-38 6-38 BQ1B045QLD BQ1B045QXD BQ1B050 BQ1B050H BQ1B050QLD BQ1B050QXD BQ1B060 BQ1B060H BQ1B060QLD BQ1B060QXD MCCB BQ1B070 BQ1B070H BQ2B010 BQ2B010QLD BQ2B010QXD BQ2B015 BQ2B015H BQ2B015QLD BQ2B015QXD BQ2B020 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-26 6-26 6-26 6-27 6-27 6-26 6-26 6-27 6-27 6-26 BQ2B020H BQ2B020QLD BQ2B020QXD BQ2B025 BQ2B025H BQ2B025QLD BQ2B025QXD BQ2B030 BQ2B030H BQ2B030QLD MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-26 6-27 6-27 6-26 6-26 6-27 6-27 6-26 6-26 6-27 BQD140 BQD145 BQD150 BQD160 BQD170 BQD180 BQD190 BQD215 BQD220 BQD225 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 BQFS2 BR2 BR3 BR4 BZLF3 BZLF3 BZLFBDC BZLFBDC BZLFRHSE BZLFRHSE BQ2B030QXD BQ2B035 BQ2B035H BQ2B035QLD BQ2B035QXD BQ2B040 BQ2B040H BQ2B040QLD BQ2B040QXD BQ2B045 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-27 6-26 6-26 6-27 6-27 6-26 6-26 6-27 6-27 6-26 BQD230 BQD235 BQD240 BQD245 BQD250 BQD260 BQD270 BQD280 BQD290 BQD290 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 BZLL3 BZLL3 BZLLBDC BZLLBDC BZLLRHSE BZLLRHSE BZLM3 BZLMBDC BZLMRHSE BZLP3 BQ2B045H BQ2B045QLD BQ2B045QXD BQ2B050 BQ2B050H BQ2B050QLD BQ2B050QXD BQ2B060 BQ2B060H BQ2B060QLD MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-26 6-27 6-27 6-26 6-26 6-27 6-27 6-26 6-26 6-27 BQD3100 BQD315 BQD320 BQD325 BQD330 BQD335 BQD340 BQD345 BQD350 BQD360 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 BZLP3 BZLPBDC BZLPBDC BZLPRHSE BZLPRHSE C01FD64 C1A18BL100CTS C1A18E4125CTS C1A18FX250CTS C1A18ML125CTS 6-139 6-139 6-139 6-139 6-139 MCCB 6-39 10-67 10-67 10-67 10-67 BQ2B060QXD BQ2B070 BQ2B070H BQ2B080 BQ2B080H BQ2B090 BQ2B090H BQ2B100 BQ2B100H BQ2B110 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-27 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 BQD370 BQD380 BQD390 BQD6115 BQD6120 BQD6125 BQD6130 BQD6135 BQD6140 BQD6145 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 C1A18ML250CTS C1A18QJ225CTS C1A30BL100CTS C1A30E4125CTS C1A30FX250CTS C1A30ML125CTS C1A30ML250CTS C1A30QJ225CTS C1A42BL100CTS C1A42E4125CTS 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 CDT2B125 CDT2B150 CDT3B050 CDT3B060 CDT3B070 CDT3B080 CDT3B090 CDT3B100 CDT3B110 CDT3B125 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 CFD63B110 CFD63B125 CFD63B150 CFD63B175 CFD63B200 CFD63B225 CFD63B250 CFD63H150 CFD63L150 CFD63S250A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-38 6-38 6-38 6-38 6-38 6-38 6-38 6-66 6-66 6-72 BQ2B110H BQ2B125 BQ2B125H BQ2H015 BQ2H020 BQ2H030 BQ2H040 BQ2H050 BQ2H060 BQ2H070 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 BQD6150 BQD6160 BQD6170 BQD6215 BQD6220 BQD6225 BQD6230 BQD6235 BQD6240 BQD6245 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 C1A42FX250CTS C1A42ML125CTS C1A42ML250CTS C1A42QJ225CTS C1C18BL100CTS C1C18E4125CTS C1C18FX250CTS C1C18ML125CTS C1C18ML250CTS C1C18QJ225CTS 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 CDT3B150 CDT3D060 CDT3D100 CDT3D150 CDT3E060 CDT3E100 CDT3E150 CDT3N060 CDT3N100 CDT3N150 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-97 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 CFS361C CFS361C5 CFS361J CFS361J5 CFS361JL CFS362J CFS362JL CFS363J CFS363JL CFS364J HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-14 4-14 4-14 4-14 4-14 4-14 4-14 4-14 4-14 4-14 6-26 6-26 6-26 6-72 6-72 6-26 6-26 6-26 6-26 6-26 BQD6250 BQD6260 BQD6270 BQD6315 BQD6320 BQD6325 BQD6330 BQD6335 BQD6340 BQD6345 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 6-21 C1C30BL100CTS C1C30E4125CTS C1C30FX250CTS C1C30ML125CTS C1C30ML250CTS C1C30QJ225CTS C1C42BL100CTS C1C42E4125CTS C1C42FX250CTS C1C42ML125CTS 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 10-67 CDT3P060 CDT3P100 CDT3P150 CDT3U060 CDT3U100 CDT3U150 CDT3X060 CDT3X100 CDT3X150 CDT4B050 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-97 CFS365J CFSAUX1NC CFSAUX1NO CFSAUXH1 CFSAUXH2 CFSH10B12 CFSH10B12 CFSH10B4 CFSH10BL12 CFSH10BL4 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-14 4-15 4-15 4-15 4-15 4-14 4-4 4-14 4-14 4-14 BQ2H080 BQ2H090 BQ2H100 BQ2S060 BQ2S100 BQ3B010 BQ3B015 BQ3B015H BQ3B020 BQ3B020H 19-2 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Product Index Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page 4-14 4-4 4-14 4-14 4-14 4-14 4-14 4-15 4-15 4-15 CJT3D400 CJT3E250 CJT3E400 CJT3N250 CJT3N400 CJT3P250 CJT3P400 CJT3U250 CJT3U400 CJT3X250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-106 6-106 6-106 6-106 6-106 6-106 6-106 6-106 6-106 6-106 CNLK30 CNLK42 CNT2B100 CNT2B120 CNT2B800 CNT2B900 CNT3B100 CNT3B120 CNT3B800 CNT3B900 UNPB 10-11 UNPB 10-11 6-117 6-117 6-117 6-117 MCCB 6-117 MCCB 6-117 6-117 6-117 CFSNFPA1 CFSNFPA2 CFSPLK CFSS10200H CFSS10400H CFSS5200 CFSS5200H CFSS5200H CFSS5400 CFSS5400H HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-15 4-15 4-15 4-14 4-14 4-14 4-14 4-4 4-14 4-14 CJT3X400 CJT4B250 CJT4B300 CJT4B350 CJT4B400 CLD62H600 CLD62L600 CLD63B450 CLD63B500 CLD63B600 MCCB 6-106 6-105 6-105 6-105 6-105 MCCB 6-66 MCCB 6-66 MCCB 6-45 MCCB 6-45 MCCB 6-45 CNT3D100 CNT3D120 CNT3D800 CNT3E100 CNT3E120 CNT3E800 CNT3N100 CNT3N120 CNT3N800 CNT3P100 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 CFSS5400H CFSSB100 CFSSB200 CFSSB400 CFSSB60 CFSTS100 CFSTS200 CFSTS400 CFT2B100 CFT2B110 HDSS 4-4 HDSS 4-15 HDSS 4-15 HDSS 4-15 HDSS 4-15 HDSS 4-15 HDSS 4-15 HDSS 4-15 MCCB 6-101 MCCB 6-101 CLD63H600 CLD63L600 CLD63S600A CLKF CLKP CLKP CLKP CLM CLM CLM MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-66 6-66 6-72 6-130 6-131 6-131 6-131 16-158 16-159 NEMA 16-72 CNT3P120 CNT3P800 CNT3U100 CNT3U120 CNT3U800 CNT3X100 CNT3X120 CNT3X800 CNT4N100 CNT4N120 CFT2B125 CFT2B150 CFT2B175 CFT2B200 CFT2B225 CFT2B250 CFT3B100 CFT3B110 CFT3B125 CFT3B150 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-101 6-101 6-101 6-101 6-101 6-101 6-101 6-101 6-101 6-101 CLM CLRSJL3 CLT2B400 CLT2B500 CLT2B600 CLT3B400 CLT3B500 CLT3B600 CLT3D400 CLT3D600 NEMA MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 16-73 6-91 6-109 6-109 6-109 6-109 6-109 6-109 6-110 6-110 CFT3B175 CFT3B200 CFT3B225 CFT3B250 CFT3D100 CFT3D150 CFT3D250 CFT3E100 CFT3E150 CFT3E250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-101 6-101 6-101 6-101 6-102 6-102 6-102 6-102 6-102 6-102 CLT3E400 CLT3E600 CLT3N400 CLT3N600 CLT3P400 CLT3P600 CLT3U400 CLT3U600 CLT3X400 CLT3X600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB CFT3N100 CFT3N150 CFT3N250 CFT3P100 CFT3P150 CFT3P250 CFT3U100 CFT3U150 CFT3U250 CFT3X100 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 CMD63A800 CMD63B500 CMD63B600 CMD63B700 CMD63B800 CMD63H800 CMD63L800 CMD63S800A CMT2B600 CMT2B700 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB CFT3X150 CFT3X250 CFT4B100 CFT4B110 CFT4B125 CFT4B150 CFT4B175 CFT4B200 CFT4B225 CFT4B250 MCCB 6-102 MCCB 6-102 6-101 6-101 6-101 6-101 6-101 6-101 6-101 6-101 CJD62H400 CJD62L400 CJD63B200 CJD63B225 CJD63B250 CJD63B300 CJD63B350 CJD63B400 CJD63H400 CJD63L400 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-66 6-66 6-41 6-41 6-41 6-41 6-41 6-41 6-66 6-66 CJD63S400A CJT2B250 CJT2B300 CJT2B350 CJT2B400 CJT3B250 CJT3B300 CJT3B350 CJT3B400 CJT3D250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-72 6-105 6-105 6-105 6-105 6-105 6-105 6-105 6-105 6-106 MCCB MCCB Product Category Page 6-59 6-59 6-120 6-120 6-120 6-121 6-121 6-121 6-121 6-121 CQD6350 CQD6360 CQDA1 CQDA1 CQDA1BA CQDA1BA CQDA2 CQDA2 CQDBA CQDBA MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-29 6-29 6-23 6-31 6-23 6-31 6-23 6-31 6-23 6-31 CPT3N160 CPT3P120 CPT3P160 CPT3U120 CPT3U160 CPT3X120 CPT3X160 CPT4N120 CPT4N160 CPT4P120 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 CQDFMB1 CQDFMB2 CQDFMB3 CQDOP CQDOP34 CQDSMK CQDST12 CQDST12 CQDST120 CQDST120 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-87 6-87 6-87 6-88 6-88 6-87 6-23 6-31 6-23 6-31 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 CPT4P160 CPT4U120 CPT4U160 CPT4X120 CPT4X160 CQD1100 CQD115 CQD120 CQD125 CQD130 MCCB MCCB MCCB MCCB MCCB 6-121 6-121 6-121 6-121 6-121 6-29 6-29 6-29 6-29 6-29 CQDST120AAS CQDST120AAS CQDST125 CQDST125 CQDST125DAS CQDST125DAS CQDST12DAS CQDST12DAS CQDST24 CQDST24 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-23 6-31 6-23 6-31 6-23 6-31 6-23 6-31 6-23 6-31 CNT4N800 CNT4P100 CNT4P120 CNT4P800 CNT4U100 CNT4U120 CNT4U800 CNT4X100 CNT4X120 CNT4X800 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 CQD135 CQD140 CQD145 CQD150 CQD160 CQD170 CQD180 CQD190 CQD2100 CQD215 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 CQDST240 CQDST240 CQDST240AAS CQDST240AAS CQDST24AAS CQDST24AAS CQDST24DAS CQDST24DAS CQDST277 CQDST277 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-23 6-31 6-23 6-31 6-23 6-31 6-23 6-31 6-23 6-31 6-110 6-110 6-110 6-110 6-110 6-110 6-110 6-110 6-110 6-110 COMEXT COMEXT COMEXT COMEXT COMEXT COMEXT COMEXT COMKIT1 COMKIT1 COMKIT1 6-138 6-138 6-139 6-139 6-139 6-139 6-139 6-138 6-138 6-139 CQD220 CQD225 CQD230 CQD235 CQD240 CQD245 CQD250 CQD260 CQD270 CQD280 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 CQDST277AAS CQDST277AAS CQDST48 CQDST48 CQDST480 CQDST480 CQDST480AAS CQDST480AAS CQDST48DAS CQDST48DAS MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-23 6-31 6-23 6-31 6-23 6-31 6-23 6-31 6-23 6-31 6-66 6-52 6-52 6-52 6-52 6-66 6-66 6-72 6-113 6-113 COMKIT1 COMKIT2 COMKIT2 COMKIT2 COMMOD COMMOD COMMOD COMMOD COMMOD COMMOD 6-139 6-139 6-139 6-139 6-138 6-138 6-139 6-139 6-139 6-139 CQD290 CQD3100 CQD315 CQD320 CQD325 CQD330 CQD335 CQD340 CQD345 CQD350 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 CQDST600 CQDST600 CQDST600AAS CQDST600AAS CRHOESD CRHOFSD CRHOH CRHOH CRHOH CRHOH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-23 6-31 6-23 6-31 6-88 6-88 4-12 4-12 4-12 4-12 CMT2B800 CMT3B600 CMT3B700 CMT3B800 CMT3D600 CMT3D800 CMT3E600 CMT3E800 CMT3N600 CMT3N800 6-113 6-113 6-113 MCCB 6-113 6-114 6-114 6-114 6-114 6-114 6-114 COMMOD COMP232 COMP232 COMP232 COMP232 COMP232 COMP232 COMP232 COMPCA COMPCA 6-139 6-138 6-138 6-139 6-139 6-139 6-139 6-139 6-138 6-138 CQD360 CQD370 CQD380 CQD390 CQD6120 CQD6125 CQD6130 CQD6135 CQD6140 CQD6145 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 CRHOH CRHOJSD CRHOLMSD CRHOS06VD CRHOS06VD CRHOS06VD CRHOS20VD CSAPELTU CSAPELTU CSAPELTU MCCB MCCB MCCB 6-88 6-88 6-88 4-12 4-12 4-12 4-12 6-138 6-138 6-139 CMT3P600 CMT3P800 CMT3U600 CMT3U800 CMT3X600 CMT3X800 CMT4N600 CMT4N800 CMT4P600 CMT4P800 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 COMPCA COMPCA COMPCA COMPCA COMPCA COMPRO COMPRO COMPRO COMPRO COMPRO 6-139 6-139 6-139 6-139 6-139 6-138 6-138 6-139 6-139 6-139 CQD6150 CQD6160 CQD6170 CQD6215 CQD6220 CQD6225 CQD6230 CQD6235 CQD6240 CQD6245 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 CSAPELTU CSAPELTU CSAPELTU CSAPELTU CTB302 CTB304 CTB306 CTB308 CTB310 CTB313 BUSW BUSW BUSW BUSW BUSW BUSW 6-139 6-139 6-139 6-139 14-51 14-51 14-51 14-51 14-51 14-51 CMT4U600 CMT4U800 CMT4X600 CMT4X800 CND63B100 CND63B120 CND63B900 CND63S120A CNFS361 CNLK18 6-114 6-114 6-114 6-114 6-56 6-56 6-56 6-72 4-14 10-11 COMPRO COMPRO COMPS COMPS COMPS COMPS COMPS COMPS COMPS CPD63B120 6-139 6-139 6-138 6-138 6-139 6-139 6-139 6-139 6-139 MCCB 6-59 CQD6250 CQD6260 CQD6270 CQD6315 CQD6320 CQD6325 CQD6330 CQD6335 CQD6340 CQD6345 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 6-29 CTB316 CTB4024 CTB4044 CTB4064 CTB4084 CTB4104 CTI2040L1200CU CTI2440L1200CU CTI3040L1200CU D115 BUSW BUSW BUSW BUSW BUSW BUSW RESI RESI RESI RESI 14-51 14-51 14-51 14-51 14-51 14-51 1-16 1-16 1-16 1-28 MCCB MCCB MCCB MCCB HDSS UNPB CPD63B140 CPD63B160 CPT3B120 CPT3B140 CPT3B160 CPT3D120 CPT3D160 CPT3E120 CPT3E160 CPT3N120 Catalog Number Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-3 PRODUCT INDEX HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS Product Category Page 19 CFSH10R12 CFSH10R12 CFSH10R4 CFSH10RL12 CFSH10RL4 CFSH5B12 CFSH5R12 CFSL100 CFSL200 CFSL400 Catalog Number Product Index Catalog Number Product Category Page Catalog Number D11CEU1 D11CEU2 D11CFU1 D11CFU2 D11CJU2 D120 D130 D140 D150 D160 MCCB MCCB MCCB MCCB MCCB RESI Product Category Page Catalog Number 6-88 6-88 6-88 6-88 6-88 1-28 1-28 1-28 1-28 1-28 DT600NK DTF224 DTF224R DTF321 DTF321R DTF322 DTF322R DTF323 DTF323R DTF324 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-30 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 E1SSND69120GN E2BMB E2HBL E2HBL E2N12 E2N12 E2N1F E2N1F E2N1S E2N1S MCCB 5-6 MCCB 6-87 MCCB 12-23 MCCB 6-86 MCCB 5-13 MCCB 6-34 5-8 6-34 MCCB 5-8 MCCB 6-34 EC56857 EC56857 EC56858 EC56858 EC56858 EC56858 EC56858 EC56933S EC56933S EC56933S RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-74 2-81 2-10 2-26 2-73 2-74 2-81 2-10 2-26 2-73 ECHS100 ECHS100 ECHS100 ECHS100 ECHS100 ECHS125 ECHS125 ECHS125 ECHS125 ECHS125 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-8 2-26 3-20 3-30 5-14 1-35 1-8 2-26 3-20 3-30 1-28 1-28 1-28 1-28 1-28 1-28 6-130 6-130 6-130 6-130 DTF324R DTF325 DTF326 DTF361 DTF362 DTF363 DTF363R DTF364 DTF364R DTF365 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 E2N3R E2N3R E2RH1 E2RHV9 E3030MB1400SCU E3030MB3400SCU E3030ML1400SCU E3030ML3400SCU E3RSHND69100GN E3RSHND69120GN MCCB MCCB MCCB MCCB RESI RESI RESI RESI MCCB MCCB 5-10 6-34 6-88 6-88 1-12 1-12 1-12 1-12 5-6 5-6 EC56933S EC56933S EC64685 EC659-0120 EC659-0121 EC9747-1113 EC9747-1113 ECA10 ECA8 ECBX231M RESG RESG RESG RESG RESG RESG BPLU BUSW RESG 2-74 2-81 2-10 2-10 2-10 2-10 2-26 14-51 14-51 1-25 ECHS125 ECHS125 ECHS150 ECHS150 ECHS150 ECHS150 ECHS150 ECHS150 ECHS150 ECHS200 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 5-14 5-14 1-35 1-8 2-26 3-20 3-30 5-14 5-14 1-35 DCAJFC3 DCAJRC3 DCALFC3 DCALRC3 DCAMFC3 DCAMRC3 DCAPFC3 DCAPFC3 DCAPRC3 DCAPRC3 6-131 6-131 6-131 6-131 6-131 6-131 6-131 6-131 6-131 6-131 DTGNF223NR DTGNF223R DTGNF224NR DTGNF224R DTGNF323NR DTGNF323R DTGNF324NR DTGNF324R DTNF221 DTNF222 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 E3RSND69100GN E3RSND69120GN E4242MB1300FCU E4242MB1300SCU E4242MB1400FCU E4242MB1400SCU E4242MB3300SCU E4242MB3400FCU E4242MB3400SCU E4242ML1400FCU MCCB MCCB RESI RESI RESI RESI RESI RESI RESI RESI 5-6 5-6 1-12 1-12 1-12 1-12 1-12 1-12 1-12 1-12 ECBX231M ECBX231M ECBX231M ECCP1 ECCP1 ECCP1U ECCP2U ECCP3 ECCP3 ECCP3U RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-26 1-35 6-19 1-35 1-8 2-81 2-81 2-10 2-26 2-74 ECHS200 ECHS200 ECHS200 ECHS200 ECHS200 ECHS200 ECHS250 ECHS250 ECHS250 ECHS250 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-8 2-26 3-20 3-30 5-14 5-14 1-35 1-8 2-26 3-20 DCHP DCHP DCHP DCHP DCHP DCHP DCHP DCIP DCIP DCIP 6-130 6-130 6-131 6-131 6-131 6-131 6-131 6-130 6-130 6-131 DTNF223 DTNF224 DTNF224R DTNF225 DTNF225R DTNF321 DTNF322 DTNF323 DTNF323R DTNF324 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 E4242ML1400SCU E4242ML3400FCU E4242ML3400SCU EA EA EB EB EB3100S EB3100S EB3100S RESI RESI RESI MCCB MCCB MCCB MCCB RESI RESI RESI 1-12 1-12 1-12 5-12 6-34 5-12 6-34 1-10 5-8 6-27 ECCP3U ECCP3U ECCS1 ECCS2 ECDL1 ECGB10 ECGB10 ECGB101 ECGB14 ECGB141 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-81 2-81 1-35 1-35 1-35 1-35 1-8 1-35 1-35 1-35 ECHS250 ECHS250 ECHV000 ECHV200 ECHV200 ECHV250 ECHV250 ECHV250 ECHV250 ECHV300 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 3-30 5-14 2-26 2-26 2-81 2-26 2-81 3-20 5-14 2-26 DCIP DCIP DCIP DCIP DCXD3 DCXF3 DCXJ3 DCXL3 DCXM3 DCXN3 6-131 6-131 6-131 6-131 6-130 6-130 6-131 6-131 6-131 6-131 DTNF324R DTNF325 DTNF326 DTNF327 DTNF361 DTNF361J DTNF361R DTNF361S DTNF362 DTNF362J HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 EB3225 EB3225F EB3225F EB3225S EBF1 EC2 EC2 EC38594 EC38594 EC38594 MCCB MCCB RESG RESG RESG 6-28 1-10 5-9 5-9 10-11 5-12 6-37 2-10 2-26 2-74 ECGB142 ECGB20 ECGB201 ECGB202 ECGB5 ECGB5 ECGK ECHA075 ECHA100 ECHA125 RESG 1-35 RESG 1-35 RESG 1-35 RESG 1-35 RESG 1-35 RESG 1-8 UNPB 10-11 RESG 3-20 3-20 3-20 ECHV300 ECHV300 ECHV300 ECHV350 ECHV350 ECHV350 ECHV350 ECHV400 ECHV400 ECHV400 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-81 3-20 5-14 2-26 2-81 3-20 5-14 2-26 2-81 3-20 6-131 10-31 10-42 10-31 10-42 10-31 6-88 6-88 4-8 6-88 DTNF362R DTNF362S DTNF363 DTNF363J DTNF363R DTNF363S DTNF364 DTNF364J DTNF364R DTNF364S HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 EC38595 EC38595 EC38595 EC38595 EC38596 EC38596 EC38596 EC38596 EC38597 EC38597 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-10 2-26 2-74 2-85 2-10 2-26 2-74 2-85 2-10 2-26 ECHBD1 ECHBD1 ECHBD1 ECHBD1 ECHBK ECHC000 ECHC000 ECHC000 ECHC200 ECHC200 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-24 1-35 6-18 6-26 2-74 2-10 2-26 2-85 2-10 2-26 ECHV400 ECINSGB14 ECINSGB20 ECINSGB5 ECJS ECJS ECLK1-2 ECLK1-2 ECLK1-2 ECLK2 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 5-14 1-35 1-35 1-35 2-10 2-81 1-35 1-8 2-26 1-35 4-8 6-88 3-30 3-30 3-30 3-30 3-30 3-30 7-12 7-12 DTNF365 DTNF365R DTNF366 DTNF366R DTNF367 DTNF367R DTNF368 DTNF368R E E HDSS 3-29 HDSS 3-29 HDSS 3-29 HDSS 3-29 HDSS 3-29 HDSS 3-29 HDSS 3-29 HDSS 3-29 NEMA 16-153 NEMA 16-154 EC38597 EC38597 EC38598 EC38598 EC38598 EC38598 EC38599 EC38599 EC38599 EC38599 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-74 2-85 2-10 2-26 2-74 2-85 2-10 2-26 2-74 2-85 ECHC200 ECHC250 ECHC250 ECHC250 ECHC300 ECHC300 ECHC300 ECHCRXA ECHCRXA ECHR075 RESG RESG RESG RESG RESG RESG RESG ECLK2 ECLK2 ECLK2125 ECLK2150 ECLK2225 ECLK2SC ECLK3 ECLK3 ECLK3125 ECLK3225 RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-8 2-26 1-35 1-35 1-35 1-35 1-35 2-26 1-35 1-35 ) 015 ) 020 ) 027 ) 034 ) 040 ) 051 ) 063 ) 075 ) 093 ) 118 7-12 7-12 7-12 7-12 7-12 7-12 7-12 7-12 7-12 7-12 E0202MB1100 E0202MB1200 E0204ML1060F E0204ML1060S E0204ML1060S E0204ML1125SCU E0303ML3100S E0303ML3100S E0408ML1125F E0816ML1125F RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-35 1-8 2-26 2-26 2-26 2-26 2-26 2-26 2-26 1-35 DT ( ) 145 DT ( ) 175 DT ( ) 220 DT ( ) 275 DT ( ) 330 DT ( ) 440 DT ( ) 550 DT ( ) 660 DT100NK DT200NK 7-12 7-12 7-12 7-12 7-12 7-12 7-12 7-12 3-30 3-30 E0816ML1125FCU E0816ML1125SCU E1020MB1100FCGP E1020MB1100FCGP E1224ML1100FCU E1224ML1100FCU E1224ML1100FG E1SSHND69100GN E1SSHND69120GN E1SSND69100GN D215 D220 D230 D240 D250 D260 DCADFC3 DCADRC3 DCAFFC3 DCAFRC3 PRODUCT INDEX 19 DCXP3 DFFP3 DFFP3 DFFP6 DFFP6 DFK1 DKL2 DKL3 DKR2 DKR2 DKR3 DKR3 DS100GK DS200EK1 DS200EK2 DS200GK DS468GK DS800NK DT ( ) 007 DT ( ) 011 DT ( DT ( DT ( DT ( DT ( DT ( DT ( DT ( DT ( DT ( 19-4 RESI RESI RESI RESI RESI RESI RESI RESI PBSB PBSB PBSB PBSB PBSB MCCB MCCB MCCB MCCB MCCB MCCB HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS Product Category Page Catalog Number RESI RESI RESI Product Category Page Catalog Number RESG 2-85 2-10 2-26 2-85 2-10 2-26 2-85 2-26 2-85 2-81 RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-10 1-10 1-10 1-10 5-8 1-10 1-10 5-8 1-9 1-9 EC38600 EC38600 EC38600 EC38600 EC4 EC4 EC56854 EC56854 EC56854 EC56855 RESG RESG RESG RESG MCCB MCCB RESG RESG RESG RESG 2-10 2-26 2-74 2-85 5-12 6-41 2-73 2-74 2-81 2-73 ECHR075 ECHR100 ECHR100 ECHR125 ECHR125 ECHR150 ECHR150 ECHR200 ECHR200 ECHS000 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 5-14 2-81 5-14 2-81 5-14 2-81 5-14 2-81 5-14 1-35 ECLKB1 ECLKB1 ECLX068M ECLX069M ECLX071M ECLX072M ECLX073M ECLX074M ECLX075M ECMBF125 RESI RESI RESI RESI RESI RESI RESI MCCB MCCB MCCB 1-9 1-9 1-13 1-9 1-13 1-9 1-9 5-6 5-6 5-6 EC56855 EC56855 EC56856 EC56856 EC56856 EC56856 EC56856 EC56857 EC56857 EC56857 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-74 2-81 2-10 2-26 2-73 2-74 2-81 2-10 2-26 2-73 ECHS000 ECHS000 ECHS000 ECHS075 ECHS075 ECHS075 ECHS075 ECHS075 ECHS075 ECHS100 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-8 2-26 3-20 1-35 1-8 2-26 3-20 3-30 5-14 1-35 ECMBR1 ECMBR2 ECMLK125 ECMLK225 ECMM5J ECMM5J ECMMI5J ECMMI5J ECP10 ECP6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Product Category Page RESG 1-35 RESG 1-35 RESG 1-35 RESG 1-35 RESG 2-74 RESG 2-81 RESG 2-74 RESG 2-81 BUSW 14-51 BUSW 14-51 Product Index Catalog Number ECP6 ECP6 ECP6 ECPLD1 ECPLD1 ECPLD1 ECPLD1 ECPLD1 ECPLD125 ECPLD2 Product Category Page BUSW 14-51 BUSW 14-51 BUSW 14-51 RESG 1-35 RESG 6-18 RESG 6-19 RESG 6-26 RESG 6-86 RESG 1-35 RESG 1-35 RESG RESG RESG RESG Catalog Number Product Category Page Catalog Number ED41B040 ED41B045 ED41B050 ED41B060 ED41B070 ED41B080 ED41B090 ED41B100 ED42B015 ED42B020 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 ED63B060 ED63B070 ED63B080 ED63B090 ED63B100 ED63B110 ED63B125 ED63S100A ED63S125A ED6SS4 ED42B025 ED42B030 ED42B035 ED42B040 ED42B045 ED42B050 ED42B060 ED42B070 ED42B080 ED42B090 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 ED6SS4 EE EE EGK EJP302 EJP304 EJP306 EJP308 EJP310 EJP313 Product Category Page MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB Catalog Number Product Category Page Catalog Number Product Category Page 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-72 6-72 5-12 F657 F657 F657 F657D F657D F657D F657D F657D F657D F657D PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB 4-21 4-21 4-21 10-61 10-61 10-61 10-61 10-61 10-61 10-61 FD62F250 FD62T070 FD62T070 FD62T080 FD62T080 FD62T090 FD62T090 FD62T100 FD62T100 FD62T110 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-37 6-37 6-38 6-37 6-38 6-37 6-38 6-37 6-38 6-37 MCCB MCCB UNPB BUSW BUSW BUSW BUSW BUSW BUSW 6-34 5-12 6-41 10-11 14-50 14-50 14-50 14-50 14-50 14-50 F657D F657D F657D F657D F657D F657D F671 F671 F671D F671D PBSB 4-21 PBSB 4-21 PBSB 4-21 PBSB 4-21 PBSB 4-21 PBSB 4-21 PBSB 10-50 PBSB 4-21 PBSB 10-61 PBSB 4-21 FD62T110 FD62T125 FD62T125 FD62T150 FD62T150 FD62T175 FD62T175 FD62T200 FD62T200 FD62T225 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-38 6-37 6-38 6-37 6-38 6-37 6-38 6-37 6-38 6-37 14-50 14-50 14-50 14-50 14-50 14-50 6-138 6-138 6-139 6-139 F672 F672 F672D F672D F6N12 F6N12 F6N1F F6N1S F6N1S F6N3R PBSB 10-50 PBSB 4-21 PBSB 10-61 PBSB 4-21 5-13 6-37 MCCB 5-8 MCCB 5-8 MCCB 6-37 MCCB 5-10 FD62T225 FD62T250 FD62T250 FD63B070 FD63B080 FD63B090 FD63B100 FD63B110 FD63B125 FD63B150 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-38 6-37 6-38 6-37 6-37 6-37 6-37 6-37 6-37 6-37 MCCB MCCB MCCB 6-37 6-88 6-88 6-132 6-132 6-133 6-133 6-133 6-133 6-133 FD63B175 FD63B200 FD63B225 FD63B250 FD63F250 FD63T070 FD63T070 FD63T070 FD63T080 FD63T080 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-37 6-37 6-37 6-37 6-37 6-37 6-38 6-38 6-37 6-38 ECQF3 ECQF3 ECQF3 ECQFL1 ECQFL2 ECQFL2 ECQL1 ECQL1 ECQLD3 ECQLD3 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 1-35 1-8 2-74 1-35 1-35 1-8 1-35 6-86 1-24 6-18 ED42B100 ED42B110 ED42B125 ED42S100A ED42S125A ED43B015 ED43B020 ED43B025 ED43B030 ED43B035 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-72 6-72 6-34 6-34 6-34 6-34 6-34 EJP316 EJP4024 EJP4044 EJP4064 EJP4084 EJP4104 ELTPHB ELTPHB ELTPHB ELTPHB BUSW BUSW BUSW BUSW BUSW BUSW MCCB MCCB MCCB MCCB ECQLD3 ECQLD3 ECQLN3 ECQML12 ECQML12 ECQTH2 ECQTH3 ECRLK250 ECSMK1 ECSN1 RESG RESG RESG RESG RESG RESG RESG RESG RESG 6-26 6-86 1-35 1-35 6-87 1-35 6-86 1-35 1-35 1-35 ED43B040 ED43B045 ED43B050 ED43B060 ED43B070 ED43B080 ED43B090 ED43B100 ED43B110 ED43B125 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 ELTPHB ELTPHB ELTPHB EMC5J EP EPC06 EPC08 EPC12 EPC18 EPC24 MCCB 6-139 MCCB 6-139 MCCB 6-139 RESG 2-26 MCCB 6-80 MCCB 6-80 MCCB 6-80 MCCB 6-80 MCCB 6-80 6-80 F6N3R F6RH1 F6RHV9 FBCD3 FBCF3 FBCJ3 FBCL3 FBCM3 FBCP3 FBCP3 ECTS2 ECTS2 ED21B015 ED21B020 ED21B025 ED21B030 ED21B035 ED21B040 ED21B045 ED21B050 RESG RESG MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 1-35 1-8 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 ED43S100A ED43S125A ED6 ED6 ED61B015 ED61B020 ED61B025 ED61B030 ED61B035 ED61B040 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-72 6-72 5-12 6-45 6-34 6-34 6-34 6-34 6-34 6-34 EPSB4DMK EPSB4FMK EPSBDMK EPSBFMK EPSP18V EPSP18V EPSP18V EPSP18V EPSP18V EPSP18V PWCB PWCB PWCB PWCB MCCB MCCB MCCB MCCB MCCB MCCB 6-80 6-80 6-80 6-80 6-138 6-138 6-139 6-139 6-139 6-139 FC3022 FC3025 FC3042 FC3045 FC3062 FC3065 FC3085 FC3125 FC4022 FC4025 14-59 14-59 14-59 14-59 14-59 14-59 14-59 14-59 14-59 14-59 FD63T080 FD63T090 FD63T090 FD63T090 FD63T100 FD63T100 FD63T100 FD63T110 FD63T110 FD63T110 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-38 6-37 6-38 6-38 6-37 6-38 6-38 6-37 6-38 6-38 ED21B060 ED21B070 ED21B080 ED21B090 ED21B100 ED22B015 ED22B020 ED22B025 ED22B030 ED22B035 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 ED61B040 ED61B050 ED61B060 ED61B070 ED61B080 ED61B090 ED61B100 ED62B015 ED62B020 ED62B025 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 EPSP18V ETB302 ETB304 ETB306 ETB308 ETB310 ETB313 ETB316 ETB4024 ETB4044 MCCB BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW 6-139 14-51 14-51 14-51 14-51 14-51 14-51 14-51 14-51 14-51 FC4042 FC4045 FC4062 FC4065 FC4085 FC4125 FCJK603 FCJK606 FCJK606 FCK203 HDSS HDSS HDSS HDSS 14-59 14-59 14-59 14-59 14-59 14-59 4-11 4-11 4-11 4-11 FD63T125 FD63T125 FD63T125 FD63T150 FD63T150 FD63T150 FD63T175 FD63T175 FD63T175 FD63T200 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-37 6-38 6-38 6-37 6-38 6-38 6-37 6-38 6-38 6-37 ED22B040 ED22B045 ED22B050 ED22B060 ED22B070 ED22B070 ED22B090 ED22B100 ED22S100A ED23B015 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-72 6-34 ED62B030 ED62B035 ED62B040 ED62B045 ED62B050 ED62B060 ED62B070 ED62B080 ED62B090 ED62B100 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 ETB4064 ETB4084 ETB4104 EWK1 EWK2 EX11 EXSTD F353SSDTK F354SSDTK F355SSDTK BUSW BUSW BUSW UNPB UNPB MCCB 14-51 14-51 14-51 10-11 10-11 6-86 6-86 HDSS 3-29 HDSS 3-29 HDSS 3-29 FCK206 FCK206 FCK206 FCK606 FCK606 FCK610 FCK610 FCK610 FCK610 FCK620 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-11 4-11 4-11 4-11 4-11 4-11 4-11 4-11 4-11 4-11 FD63T200 FD63T200 FD63T225 FD63T225 FD63T225 FD63T250 FD63T250 FD63T250 FD6HB1 FD6PL1 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-38 6-38 6-37 6-38 6-38 6-37 6-38 6-38 6-86 6-86 ED23B020 ED23B025 ED23B030 ED23B035 ED23B040 ED23B045 ED23B050 ED23B060 ED23B070 ED23B080 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 ED62S100A ED63A001 ED63A002 ED63A003 ED63A005 ED63A010 ED63A025 ED63A030 ED63A040 ED63A050 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-72 6-66 6-66 6-66 6-66 6-66 6-66 6-66 6-66 6-66 F56B F602 F602 F602D F602D F6150D F6150D F6162D F6162D F6162D UNPB PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB 10-10 10-50 4-21 10-61 4-21 10-61 4-21 10-61 12-26 4-22 FCK620 FCK620 FCK620 FCRK203 FCRK206 FCRK206 FCRK206 FCRK606 FCRK606 FD62B070 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS MCCB 4-11 4-11 4-11 4-11 4-11 4-11 4-11 4-11 4-11 6-37 FD6SS4 FD6SS4 FDFBEL FDFBEL4 FDFBER FDFBER4 FDFBFL FDFBFL4 FDFBFR FDFBFR4 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 5-12 6-37 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 ED23B090 ED23B100 ED23S100A ED2HPL ED2HPL ED41B015 ED41B020 ED41B020 ED41B030 ED41B035 MCCB 6-34 MCCB 6-34 MCCB 6-72 MCCB 12-23 MCCB 6-86 MCCB 6-34 MCCB 6-34 MCCB 6-34 MCCB 6-34 MCCB 6-34 ED63A100 ED63A125 ED63B015 ED63B020 ED63B025 ED63B030 ED63B035 ED63B040 ED63B045 ED63B050 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-66 6-66 6-34 6-34 6-34 6-34 6-34 6-34 6-34 6-34 F657 F657 F657 F657 F657 F657 F657 F657 F657 F657 PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB PBSB 10-50 10-50 10-50 10-50 10-50 10-50 10-50 4-21 4-21 4-21 FD62B080 FD62B090 FD62B100 FD62B110 FD62B125 FD62B150 FD62B175 FD62B200 FD62B225 FD62B250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-37 6-37 6-37 6-37 6-37 6-37 6-37 6-37 6-37 6-37 FDFS06L FDFS06L FDFS06L FDFS06R FDFS06R FDFS06R FDFS20L FDFS20R FDH10 FDH10 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-5 PRODUCT INDEX RESG RESG RESG RESG RESG 6-18 6-19 6-26 6-86 1-35 2-10 2-26 2-74 2-74 2-81 19 ECPLD2 ECPLD2 ECPLD2 ECPLD2 ECPLD2R ECPP ECPP ECPP ECPP ECPP Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page FDH10 FDH10 FDH10 FDH10 FDH104 FDH20 FDH20 FDH204 FDS06L FDS06L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 FHOJC036 FHOJC036 FHOJC048 FHOJC048 FHOJC060 FHOJC060 FHOJC072 FHOJC084 FHOJC096 FHOJC120 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-89 6-89 4-12 6-89 4-12 6-89 6-89 6-89 6-89 6-89 G1224L1125CP G1224L1125CU G1224L1125CUSG G1224L1200CU G1224L3125CU G1224L3200CU G1624B1100 G1624B1100CU G1624L1125 G1624L1125CP RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-8 1-7 1-7 1-7 1-11 1-11 1-7 1-7 1-7 1-8 GF225NH GF225NR GF225NRH GF226N GF226NH GF226NR GF226NRH GF321N GF321NR GF322N GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 HB2B035 HB2B040 HB2B045 HB2B050 HB2B060 HB2B070 HB2B080 HB2B090 HB2B100 HB2B110 FDS06L FDS06R FDS06R FDS06R FDS20L FDS20R FE100 FE200 FEP302 FEP304 MCCB MCCB MCCB MCCB FHOJC144 FHOLM036 FHOLMBO FHON048 FHONBO FHONC048 FHONC048 FHONC060 FHONC072 FHONC084 MCCB MCCB MCCB MCCB HDSS HDSS BUSW BUSW 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 14-50 14-50 MCCB MCCB MCCB MCCB MCCB MCCB 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 G1624L1125CU G1624L1125CUSG G1630B1150 G1836L3150CU G1836L3200CU G2020B1100 G2020B1100CP G2020B1100CU G2020L1125 G2020L1125CU RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-7 1-7 1-7 1-11 1-11 1-7 1-8 1-7 1-7 1-7 GF322NR GF323N GF323NR GF324N GF324NR GF325N GF325NH GF325NR GF325NRH GF326N GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 HB2B125 HB3B010 HB3B015 HB3B020 HB3B025 HB3B030 HB3B035 HB3B040 HB3B045 HB3B050 MCCB 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 FEP306 FEP308 FEP310 FEP313 FEP316 FEP4024 FEP4044 FEP4064 FEP4084 FEP4104 BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW 14-50 14-50 14-50 14-50 14-50 14-50 14-50 14-50 14-50 14-50 FHONC096 FHONC120 FHONC144 FHOS06036L FHOS06036L FHOS06036L FHOS06036R FHOS06036R FHOS06036R FHOS06L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-89 6-89 6-89 4-12 4-12 4-12 4-12 4-12 4-12 4-12 G2030B1150 G2030B1150CU G2030L1125CUSG G2030L1150 G2030L1150CU G2030L1150CUSG G2040B1200 G2040B1200CU G2040L1200 G2040L1200CU RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-7 GF326NH GF326NR GF326NRH GG01212N GG0121FN/SN GG0123RN GH223 GH223 GH223 GH24 GDSS GDSS GDSS MCCB MCCB HDSS HDSS HDSS HDSS 3-8 3-8 3-8 5-13 5-8 5-10 3-34 3-34 3-34 3-34 HB3B060 HB3B070 HB3B080 HB3B090 HB3B100 HBB21 HBB22 HBB612 HBB612 HBB62 MCCB MCCB MCCB MCCB MCCB HDSS HDSS HDSS HDSS HDSS 6-26 6-26 6-26 6-26 6-26 3-34 3-34 3-34 3-34 3-34 FG0221S FG02512 FG0251F FG0251S FG0253R FG0254S FG02579 FHOE036 FHOEBO FHOEC036 6-100 6-100 6-100 6-100 6-100 6-100 6-100 MCCB 6-89 MCCB 6-89 MCCB 4-12 FHOS06L FHOS06L FHOS06R FHOS06R FHOS06R FHOS20036L FHOS20036R FHOS20L FHOS20R FHVF3R MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 6-128 G2424B1100CU G2424B1125 G2424L1125 G2430B1150 G2430L1125CUSG G2440B1200 G2440L1125CU G2440L1200 G2440L1200CU G2442B3150CU RESI RESI RESI RESI RESI RESI RESI 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-11 GMBC1 GMBC2 GNF321 GNF321R GNF322 GNF322R GNF323 GNF323R GNF324 GNF324R GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS 2-82 2-82 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 HBB63 HBB64 HBB656 HBB656 HBB67A HBB68 HBDE HBDF HBDF HBDL HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 MCCB 6-86 MCCB 6-136 MCCB 6-136 MCCB 6-137 FHOEC036 FHOEC036 FHOEC036 FHOEC036 FHOEC036 FHOEC036 FHOEC036 FHOEC048 FHOEC048 FHOEC048 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 4-12 4-12 4-12 4-12 4-12 4-7 6-89 4-12 4-7 6-89 FHVF3RB FHVF4X FHVL3R FHVL3RB FHVL4X FMHOS FMPG1 FMPG2 FMPG3 FP9508 6-128 6-128 6-128 6-128 6-128 MCCB 6-88 6-87 6-87 6-87 MCCB 6-87 G2442L3150CU G2442L3200CU G3030B1100CP G3030B1100CU G3030B1150 G3030B1150CP G3030B1150CU G3030B3100CU G3030L1200 G3030L1200CU RESI RESI RESI RESI RESI 1-11 1-11 1-8 1-7 1-7 1-8 1-7 1-11 1-7 1-7 GNF325 GNF326 GSGK60 GSGK60 GSRK321 H55890 H56476 H56476 H56732 H56732-2 3-8 3-8 3-19 3-33 3-17 2-10 2-10 2-73 2-10 2-73 HBDL HBDM HBDP HBDP HCL612 HCL623 HCL65 HCL65678 HCL65678 HCP327HT MCCB MCCB MCCB MCCB HDSS HDSS HDSS HDSS HDSS VBSS 6-137 6-137 6-137 6-137 3-20 3-20 3-20 3-20 3-20 4-22 FHOEC060 FHOEC060 FHOEC072 FHOEC084 FHOEC096 FHOEC120 FHOEC144 FHOF036 FHOFBO FHOFC036 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 4-12 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 FP9555 FP9556 FR325DTK FR326DTK FR355DTK FXD62B070 FXD62B080 FXD62B090 FXD62B100 FXD62B110 MCCB MCCB HDSS HDSS HDSS MCCB MCCB MCCB MCCB MCCB 6-87 6-87 3-29 3-29 3-29 6-37 6-37 6-37 6-37 6-37 G3040B1200 G3040B1200CP G3040B1200CPP G3040B1200CU G3040L1125CU G3040L1200 G3040L1200CP G3040L1200CP1 G3040L1200CPP G3040L1200CU RESI RESI RESI RESI RESI RESI RESI 1-7 1-8 1-8 1-7 1-7 1-7 1-8 1-8 1-8 1-7 H56732-M H58022 H58852 H59676 H60162 H68752-1 HA161234 HA161234 HA161234 HA165678 HDSS HDSS HDSS HDSS 2-73 2-10 2-10 2-10 2-73 2-73 3-18 3-30 4-9 3-18 HCP327VT HCP328HT HCP328VT HCP367H HCP367HJ400 HCP367HJ600 HCP367V HCP367VJ400 HCP367VJ600 HCP368H VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS 4-22 4-22 4-22 4-22 4-22 4-22 4-22 4-22 4-22 4-22 FHOFC048 FHOFC060 FHOFC072 FHOFC084 FHOFC096 FHOFC120 FHOFC144 FHOH FHOH FHOH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 6-89 FXD62B125 FXD62B150 FXD62B175 FXD62B200 FXD62B225 FXD62B250 FXD62S250A FXD63A250 FXD63B070 FXD63B080 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-37 6-37 6-37 6-37 6-37 6-37 6-72 6-66 6-37 6-37 G3040L1200CUSG G3042B3200CU G3042L3200CU G4040B1200 G4040B1200CP G4040B1200CP1 G4040B1200CPP G4040B1200CU G4040B1200CUSGP G4040L1200 RESI RESI RESI RESI RESI HA165678 HA165678 HA2 HA261234 HA261234 HA261234 HA265678 HA265678 HA265678 HA361234 HDSS 3-30 HDSS 4-9 NEMA 16-89 HDSS 3-18 HDSS 3-30 HDSS 4-9 HDSS 3-18 HDSS 3-30 HDSS 4-9 HDSS 3-18 HCP368V HCPCLP HCPST120 HCPST125 HCPST240 HCPST277 HCPST48 HCPST480 HDG2B050L HDG2B060L VBSS VBSS VBSS RESI RESI RESI RESI 1-7 1-11 1-11 1-7 1-8 1-8 1-8 1-7 1-8 1-7 4-22 4-22 4-22 4-22 4-22 4-22 4-22 4-22 6-97 6-97 FHOH FHOH4 FHOH4 FHOH4 FHOH4 FHOHN FHOHN4 FHOHS FHOHS FHOHS MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-89 6-89 6-89 6-89 6-89 6-89 6-89 4-12 4-12 4-12 FXD63B090 FXD63B100 FXD63B110 FXD63B125 FXD63B150 FXD63B175 FXD63B200 FXD63B225 FXD63B250 FXD63H150 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-37 6-37 6-37 6-37 6-37 6-37 6-37 6-37 6-37 6-66 G4040L1200CPP G4040L1200CU G4040L1200CUSG G4242B1225CU G4242B3200CU G4242B3225CU G4242L1225CU G4242L3225CU GF01ED60 GF01ED60B0 RESI RESI RESI RESI RESI RESI RESI MCCB MCCB 1-8 1-7 1-7 1-7 1-11 1-11 1-7 1-11 6-36 6-36 HA361234 HA365678 HA365678 HAS1 HB HB1B015 HB1B020 HB1B025 HB1B030 HB1B035 HDSS 4-9 HDSS 3-18 HDSS 4-9 MCCB 6-89 NEMA 16-84 MCCB 6-26 MCCB 6-26 6-26 MCCB 6-26 6-26 HDG2B070L HDG2B080L HDG2B090L HDG2B100L HDG2B110L HDG2B125L HDG2B150L HDG2F150 HDG3B050L HDG3B060L FHOHS FHOHS FHOHS FHOHS FHOHS FHOHS4 FHOJ036 FHOJBO FHOJC036 FHOJC036 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 4-12 4-12 4-12 4-12 4-12 4-12 6-89 6-89 4-12 4-12 FXD63L150 FXD63L150 FXD63S250A G1212L1125 G1212L1125CU G1224B10060GC G1224B1100 G1224B1100CU G1224B6060GC G1224L1125 MCCB MCCB MCCB RESI RESI RESI RESI RESI RESI RESI 6-66 6-66 6-72 1-7 1-7 1-13 1-7 1-7 1-13 1-7 GF01ED60BC GF221N GF221NR GF222N GF222NR GF223N GF223NR GF224N GF224NR GF225N MCCB GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS GDSS 6-36 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 HB1B040 HB1B045 HB1B050 HB1B060 HB1B070 HB2B010 HB2B015 HB2B020 HB2B025 HB2B030 MCCB HDG3B070L HDG3B080L HDG3B090L HDG3B100L HDG3B110L HDG3B125L HDG3B150L HDG3D060L HDG3D100L HDG3D150L 19-6 RESI RESI RESI RESI RESI RESI RESI Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog GDSS GDSS HDSS HDSS HDSS MCCB MCCB MCCB MCCB 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB VBSS VBSS VBSS VBSS MCCB 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-26 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-98 6-98 6-98 Product Index Catalog Number HDG3E060L HDG3E100L HDG3E150L HDG3F150 HDG3F150 HDG3F150 HDG3N060L HDG3N100L HDG3N150L HDG3P060L Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page 6-98 6-98 6-98 6-97 6-98 6-98 6-98 6-98 6-98 6-98 HED41B100 HED42B015 HED42B020 HED42B025 HED42B030 HED42B035 HED42B040 HED42B045 HED42B050 HED42B060 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 HEG4B125L HES3S100L HES3S125L HF221J HF221N HF221NR HF221S HF222J HF222N HF222NR MCCB MCCB HDSS HDSS HDSS HDSS HDSS HDSS HDSS 6-32 6-72 6-72 3-10 3-10 3-10 3-10 3-10 3-10 3-10 HF327NR HF327S HF328N HF328NR HF361 HF361J HF361JCH HF361JCHW HF361JPN HF361JW HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-10 3-10 3-10 3-10 3-11 3-11 3-15 3-15 3-15 3-13 HF461 HF461J HF462 HF462J HF463 HF463J HF464 HF464J HF63CX HF63CX HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDG3P100L HDG3P150L HDG3U060L HDG3U100L HDG3U150L HDG3X060L HDG3X100L HDG3X150L HDG4B050L HDG4B060L 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-97 6-97 HED42B070 HED42B080 HED42B090 HED42B100 HED42B110 HED42B125 HED43B015 HED43B020 HED43B025 HED43B030 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 HF222S HF223J HF223N HF223NR HF223S HF224J HF224N HF224NR HF224S HF225N HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 HF361L HF361N HF361NR HF361NX HF361R HF361RL HF361S HF361SCH HF361SCHW HF361SPN HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-11 3-11 3-16 3-11 3-11 3-11 3-15 3-15 3-15 HF661J HF661S HF662J HF662S HF663J HF663S HF664J HF664S HFB HFB21 HDSS 3-14 HDSS 3-14 HDSS 3-14 HDSS 3-14 HDSS 3-14 HDSS 3-14 HDSS 3-14 HDSS 3-14 NEMA 16-87 HDSS 3-34 HDG4B070L HDG4B080L HDG4B090L HDG4B100L HDG4B110L HDG4B125L HDG4B150L HDG4F150 HDM3H150L HDM3L150L 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 MCCB 6-124 MCCB 6-124 HED43B035 HED43B040 HED43B045 HED43B050 HED43B060 HED43B070 HED43B080 HED43B090 HED43B100 HED43B110 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 HF225NH HF225NR HF225NRH HF226N HF226NH HF226NR HF226NRH HF227N HF227NR HF228N HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 HF361SW HF362 HF362J HF362JCH HF362JCHW HF362JPN HF362JW HF362N HF362NR HF362NX HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-13 3-11 3-11 3-15 3-15 3-15 3-13 3-11 3-11 3-16 HFB22 HFB612 HFB612 HFB62 HFB63 HFB64 HFB65 HFB66 HFB67A HFB68 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 HDM3M150L HDS2S150L HDS3S150L HEB1B015B HEB1B020B HEB1B025B HEB1B030B HEB1B035B HEB1B040B HEB1B045B MCCB 6-124 MCCB 6-123 MCCB 6-123 MCCB 6-24 MCCB 6-24 MCCB 6-24 MCCB 6-24 MCCB 6-24 MCCB 6-24 MCCB 6-24 HED43B125 HEG1B015L HEG1B020L HEG1B025L HEG1B030L HEG1B035L HEG1B040L HEG1B045L HEG1B050L HEG1B060L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 HF228NR HF261 HF261J HF261R HF261S HF262 HF262J HF262R HF262S HF263 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-10 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 HF362R HF362RL HF362S HF362SCH HF362SCHW HF362SPN HF362SW HF363 HF363J HF363JCH HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-11 3-11 3-15 3-15 3-15 3-13 3-11 3-11 3-15 HFD62B070 HFD62B080 HFD62B090 HFD62B100 HFD62B110 HFD62B125 HFD62B150 HFD62B175 HFD62B200 HFD62B225 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-38 6-38 6-38 6-38 6-38 6-38 6-38 6-38 6-38 6-38 HEB1B050B HEB1B060B HEB1B070B HEB1B080B HEB1B090B HEB1B100B HEB1B110B HEB1B125B HEB2B015B HEB2B020B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 HEG1B070L HEG1B080L HEG1B090L HEG1B100L HEG1B110L HEG1B125L HEG2B015L HEG2B020L HEG2B025L HEG2B030L MCCB MCCB MCCB MCCB MCCB MCCB 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 HF263J HF263R HF263S HF265 HF265J HF265R HF265S HF266 HF266J HF266R HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 HF363JCHW HF363JW HF363N HF363NR HF363NX HF363R HF363S HF363SCH HF363SCHW HF363SW HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-15 3-13 3-11 3-11 3-16 3-11 3-11 3-15 3-15 3-13 HFD62B250 HFD62F250 HFD63B070 HFD63B080 HFD63B090 HFD63B100 HFD63B110 HFD63B125 HFD63B150 HFD63B175 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-38 6-38 6-38 6-38 6-38 6-38 6-38 6-38 6-38 6-38 HEB2B025B HEB2B030B HEB2B035B HEB2B040B HEB2B045B HEB2B050B HEB2B060B HEB2B070B HEB2B080B HEB2B090B MCCB MCCB MCCB HEG2B035L HEG2B040L HEG2B045L HEG2B050L HEG2B060L HEG2B070L HEG2B080L HEG2B090L HEG2B100L HEG2B110L 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 HF266S HF321J HF321JCH HF321N HF321NR HF321NX HF321S HF321SCH HF322J HF322JCH HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-10 3-15 3-10 3-10 3-16 3-10 3-15 3-10 3-15 HF364 HF364J HF364JW HF364N HF364NR HF364NX HF364R HF364S HF364SW HF365 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-11 3-13 3-11 3-11 3-16 3-11 3-11 3-13 3-11 HFD63B200 HFD63B225 HFD63B250 HFD63F250 HFG2B100L HFG2B110L HFG2B125L HFG2B150L HFG2B175L HFG2B200L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-38 6-38 6-38 6-38 6-101 6-101 6-101 6-101 6-101 6-101 HEB2B100B HEB2B110B HEB2B125B HEB3B015B HEB3B020B HEB3B025B HEB3B030B HEB3B035B HEB3B040B HEB3B045B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 HEG2B125L HEG3B015L HEG3B020L HEG3B025L HEG3B030L HEG3B035L HEG3B040L HEG3B045L HEG3B050L HEG3B060L 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 HF322JPN HF322N HF322NR HF322NX HF322S HF322SCH HF323J HF323JCH HF323N HF323NR HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-15 3-10 3-10 3-16 3-10 3-15 3-10 3-15 3-10 3-10 HF365H HF365J HF365JW HF365N HF365NR HF365R HF365RH HF365S HF365SW HF366 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-11 3-13 3-11 3-11 3-11 3-11 3-11 3-13 3-11 HFG2B225L HFG2B250L HFG2F250 HFG3B100L HFG3B110L HFG3B125L HFG3B150L HFG3B175L HFG3B200L HFG3B225L 6-101 6-101 MCCB 6-101 6-101 6-101 6-101 6-101 6-101 6-101 6-101 HEB3B050B HEB3B060B HEB3B070B HEB3B080B HEB3B090B HEB3B100B HEB3B110B HEB3B125B HED41B015 HED41B020 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-35 6-35 HEG3B070L HEG3B080L HEG3B090L HEG3B100L HEG3B110L HEG3B125L HEG4B015L HEG4B020L HEG4B025L HEG4B030L 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 HF323S HF323SCH HF324J HF324N HF324NR HF324S HF325J HF325N HF325N HF325NH HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-10 3-15 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 HF366H HF366J HF366JW HF366N HF366NR HF366R HF366RH HF366S HF367 HF367J HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-11 3-13 3-11 3-11 3-11 3-11 3-11 3-11 3-11 HFG3B250L HFG3D100L HFG3D150L HFG3D250L HFG3E100L HFG3E150L HFG3E250L HFG3F250 HFG3F250 HFG3F250 6-101 6-102 6-102 6-102 6-102 6-102 6-102 MCCB 6-101 MCCB 6-102 MCCB 6-102 HED41B025 HED41B030 HED41B035 HED41B040 HED41B045 HED41B050 HED41B060 HED41B070 HED41B080 HED41B090 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 HEG4B035L HEG4B040L HEG4B045L HEG4B050L HEG4B060L HEG4B070L HEG4B080L HEG4B090L HEG4B100L HEG4B110L 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 HF325NRH HF325S HF326J HF326N HF326NH HF326NR HF326NRH HF326S HF327J HF327N HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 3-10 HF367N HF367NR HF367R HF367S HF368 HF368J HF368N HF368NR HF368R HF368S HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 3-11 HFG3N100L HFG3N150L HFG3N250L HFG3P100L HFG3P150L HFG3P250L HFG3U100L HFG3U150L HFG3U250L HFG3X100L 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 MCCB MCCB MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-7 PRODUCT INDEX MCCB MCCB MCCB MCCB MCCB MCCB 19 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 3-14 3-14 3-14 3-14 3-14 3-14 3-14 3-14 3-33 4-4 Product Index Catalog Number Product Category PRODUCT INDEX 19 HFG3X150L HFG3X250L HFG4B100L HFG4B110L HFG4B125L HFG4B150L HFG4B175L HFG4B200L HFG4B225L HFG4B250L Page Catalog Number Product Category Page 6-102 6-102 6-101 6-101 6-101 6-101 6-101 6-101 6-101 6-101 HHFD63B175 HHFD63B200 HHFD63B225 HHFD63B250 HHFD63F250 HHJD62B200 HHJD62B225 HHJD62B250 HHJD62B300 HHJD62B350 MCCB MCCB MCCB MCCB MCCB MCCB MCCB Catalog Number Product Category Page MCCB MCCB 6-38 6-38 6-38 6-38 6-38 6-41 6-41 6-41 6-41 6-41 HL612 HL612 HL612 HL612 HL612 HL612 HL612 HL63 HL63 HL64 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 Catalog Number Product Category Page Catalog Number Product Category Page HM6123 HM6123 HM6123 HM6123 HM64 HM64 HM65 HM65 HM66 HM66 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 HND63B120 HND63B800 HND63B900 HND63F120 HND678 HNF261 HNF261J HNF261R HNF261S HNF262 MCCB MCCB MCCB MCCB HDSS HDSS HDSS HDSS HDSS HDSS 6-56 6-56 6-56 6-56 3-30 3-12 3-12 3-12 3-12 3-12 HDSS HDSS 3-34 3-34 3-34 3-34 6-52 6-52 6-52 6-52 6-52 6-52 HNF262J HNF262R HNF262S HNF263 HNF263J HNF263R HNF263S HNF265 HNF265J HNF265R HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-12 3-12 3-12 3-12 3-12 3-12 3-12 3-12 3-12 3-12 6-52 6-52 6-52 6-52 6-113 6-113 6-113 6-113 6-113 6-113 HNF265S HNF266 HNF266J HNF266R HNF266S HNF3030CX HNF3060CX HNF3100CX HNF361 HNF361J HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-12 3-12 3-12 3-12 3-12 3-32 3-32 3-32 3-12 3-12 HFG4F250 HFM3H250L HFM3L250L HFM3M250L HFS2S250L HFS3S250L HFXD62S250A HFXD63S250A HG261234 HG2656 MCCB MCCB MCCB MCCB MCCB MCCB MCCB HDSS HDSS 6-101 6-124 6-124 6-124 6-123 6-123 6-72 6-72 3-19 3-19 HHJD62B400 HHJD62F400 HHJD63B200 HHJD63B225 HHJD63B250 HHJD63B300 HHJD63B350 HHJD63B400 HHJD63F400 HHLD62B250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-41 6-41 6-41 6-41 6-41 6-41 6-41 6-41 6-41 6-45 HL64 HL65678 HL65678 HL65678 HL65678 HL67A HL67A HL9419 HL9419 HLC612 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 MCCB 12-23 MCCB 6-86 HDSS 3-19 HM678 HM678 HM67A HM67A HMD62B500 HMD62B600 HMD62B700 HMD62B800 HMD62F800 HMD63B500 HG61234 HG61234 HG61234 HG61234 HG656 HG656 HG656 HG678 HG678 HH6123 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-19 3-19 3-30 4-9 3-19 3-30 4-9 3-19 3-30 3-34 HHLD62B300 HHLD62B350 HHLD62B400 HHLD62B450 HHLD62B500 HHLD62B600 HHLD62F600 HHLD62T450 HHLD62T500 HHLD62T600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 HLC612 HLC63 HLC63 HLC64 HLC64 HLC65678 HLC65678 HLD62B250 HLD62B300 HLD62B350 HDSS HDSS HDSS HDSS HDSS HDSS HDSS MCCB MCCB MCCB 4-9 3-19 4-9 3-19 4-9 3-19 4-9 6-45 6-45 6-45 HMD63B600 HMD63B700 HMD63B800 HMD63F800 HMG2B600L HMG2B700L HMG2B800L HMG2F800 HMG3B600L HMG3B700L HH6123 HH6123 HH6123 HH6123 HH6123 HH6123 HH6123 HH64 HH64 HH65678 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 HHLD63B250 HHLD63B300 HHLD63B350 HHLD63B400 HHLD63B450 HHLD63B500 HHLD63B600 HHLD63F600 HHLD63T450 HHLD63T500 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 HLD62B400 HLD62B450 HLD62B500 HLD62B600 HLD62F600 HLD63B250 HLD63B300 HLD63B350 HLD63B400 HLD63B450 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 6-45 HMG3B800L HMG3D600L HMG3D800L HMG3E600L HMG3E800L HMG3F800 HMG3F800 HMG3F800 HMG3N600L HMG3N800L 6-113 6-114 6-114 6-114 6-114 6-113 6-114 6-114 6-114 6-114 HNF361JCH HNF361JCHW HNF361JPN HNF361JW HNF361R HNF361RL HNF361S HNF361SCH HNF361SCHW HNF361SPN HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-15 3-15 3-15 3-13 3-12 3-12 3-12 3-15 3-15 3-15 HH65678 HH65678 HH65678 HH65678 HH65678 HH65678 HH65678 HH65678 HH68 HH68 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-34 HHLD63T600 HJD62B200 HJD62B225 HJD62B250 HJD62B300 HJD62B350 HJD62B400 HJD62F400 HJD63B200 HJD63B225 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-45 6-41 6-41 6-41 6-41 6-41 6-41 6-41 6-41 6-41 HLD63B500 HLD63B600 HLD63F600 HLG2B400L HLG2B500L HLG2B600L HLG2F600 HLG3B400L HLG3B500L HLG3B600L MCCB MCCB MCCB 6-45 6-45 6-45 6-109 6-109 6-109 MCCB 6-109 6-109 6-109 6-109 HMG3P600L HMG3P800L HMG3U600L HMG3U800L HMG3X600L HMG3X800L HMG4F800 HMG4N600L HMG4N800L HMG4P600L 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 HNF361SW HNF361X HNF362 HNF362H HNF362J HNF362JCH HNF362JCHW HNF362JH HNF362JPN HNF362JW HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-13 3-16 3-12 3-12 3-12 3-15 3-15 3-12 3-15 3-13 HHD61234 HHD61234S HHD65678 HHED62B015 HHED62B020 HHED62B025 HHED62B030 HHED62B035 HHED62B040 HHED62B045 HDSS HDSS MCCB MCCB MCCB MCCB MCCB MCCB MCCB 3-30 3-30 3-30 6-35 6-35 6-35 6-35 6-35 6-35 6-35 HJD63B250 HJD63B300 HJD63B350 HJD63B400 HJD63F400 HJG2B250L HJG2B300L HJG2B350L HJG2B400L HJG2F400 MCCB MCCB MCCB MCCB MCCB 6-41 6-41 6-41 6-41 6-41 6-105 6-105 6-105 6-105 MCCB 6-105 HLG3D400L HLG3D600L HLG3E400L HLG3E600L HLG3F600 HLG3F600 HLG3F600 HLG3N400L HLG3N600L HLG3P400L 6-110 6-110 6-110 6-110 MCCB 6-109 MCCB 6-110 MCCB 6-110 6-110 6-110 6-110 HMG4P800L HMG4U600L HMG4U800L HMG4X600L HMG4X800L HMM3M800 HMS2S800 HMS3S800 HMXD63B500 HMXD63B600 MCCB MCCB MCCB MCCB MCCB 6-114 6-114 6-114 6-114 6-114 6-124 6-123 6-123 6-52 6-52 HNF362R HNF362RH HNF362RL HNF362S HNF362SCH HNF362SCHW HNF362SH HNF362SPN HNF362SW HNF362X HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-12 3-12 3-12 3-12 3-15 3-15 3-12 3-15 3-13 3-16 HHED62B050 HHED62B060 HHED62B070 HHED62B080 HHED62B090 HHED62B100 HHED62B110 HHED62B125 HHED63B015 HHED63B020 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 HJG3B250L HJG3B300L HJG3B350L HJG3B400L HJG3D250L HJG3D400L HJG3E250L HJG3E400L HJG3F400 HJG3F400 6-105 6-105 6-105 6-105 6-106 6-106 6-106 6-106 MCCB 6-105 MCCB 6-106 HLG3P600L HLG3U400L HLG3U600L HLG3X400L HLG3X600L HLM3L600 HLM3M600 HLMD62B500 HLMD62B600 HLMD62B700 MCCB MCCB MCCB MCCB MCCB 6-110 6-110 6-110 6-110 6-110 6-124 6-124 6-49 6-49 6-49 HMXD63B700 HMXD63B800 HN263 HN263 HN263 HN264 HN612 HN612 HN623 HN623 MCCB MCCB HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 6-52 6-52 3-17 3-30 4-8 3-17 3-17 4-8 3-17 4-8 HNF363 HNF363J HNF363JCH HNF363JCHW HNF363JW HNF363R HNF363S HNF363SCH HNF363SCHW HNF363SW HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-12 3-12 3-15 3-15 3-13 3-12 3-12 3-15 3-15 3-13 HHED63B025 HHED63B030 HHED63B035 HHED63B040 HHED63B045 HHED63B050 HHED63B060 HHED63B070 HHED63B080 HHED63B090 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 6-35 HJG3F400 HJG3N250L HJG3N400L HJG3P250L HJG3P400L HJG3U250L HJG3U400L HJG3X250L HJG3X400L HJG4B250L MCCB 6-106 6-106 6-106 6-106 6-106 6-106 6-106 6-106 6-106 6-105 HLMD62B800 HLMD62F800 HLMD63B500 HLMD63B600 HLMD63B700 HLMD63B800 HLMD63F800 HLMXD63B500 HLMXD63B600 HLMXD63B700 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-49 6-49 6-49 6-49 6-49 6-49 6-49 6-49 6-49 6-49 HN64 HN656 HN656 HN678 HN678 HN678 HNB HNB HNB612 HNB612 HDSS 3-17 HDSS 3-17 HDSS 3-17 HDSS 3-17 HDSS 3-17 HDSS 3-30 NEMA 16-87 NEMA 16-93 HDSS 3-34 HDSS 3-34 HNF363X HNF364 HNF364J HNF364JW HNF364R HNF364S HNF364SW HNF364X HNF365 HNF365J HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-16 3-12 3-12 3-13 3-12 3-12 3-13 3-16 3-12 3-12 HHED63B100 HHED63B110 HHED63B125 HHFD63B070 HHFD63B080 HHFD63B090 HHFD63B100 HHFD63B110 HHFD63B125 HHFD63B150 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-35 6-35 6-35 6-38 6-38 6-38 6-38 6-38 6-38 6-38 HJG4B300L HJG4B350L HJG4B400L HJG4F400 HJM3L400 HJM3M400 HJS2S400 HJS3S400 HJXD63S400A HL612 6-105 6-105 6-105 6-105 6-124 6-124 6-123 6-123 6-72 3-34 HLMXD63B800 HLS2S600 HLS3S600 HLXD63S600A HM6123 HM6123 HM6123 HM6123 HM6123 HM6123 MCCB 6-49 MCCB 6-123 MCCB 6-123 MCCB 6-72 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HDSS 3-34 HNB623 HNB623 HNB64 HNB65 HNB66 HNB678 HNB67A HNC264 HNC612 HND63B100 HDSS HDSS HDSS HDSS HDSS HDSS HNF365JW HNF365R HNF365S HNF365SW HNF366 HNF366J HNF366R HNF366S HNF367 HNF367J HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-13 3-12 3-12 3-13 3-12 3-12 3-12 3-12 3-12 3-12 19-8 MCCB MCCB MCCB MCCB MCCB HDSS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB HDSS HDSS MCCB 3-34 3-34 3-34 3-34 3-34 3-34 3-34 3-30 3-30 6-56 Product Index Catalog Number Product Category HNF367R HNF367S HNF368 HNF368J HNF368R HNF368S HNF461 HNF461J HNF462 HNF462J HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-12 3-12 3-12 3-12 3-12 3-12 3-14 3-14 3-14 3-14 HPG3F160 HPG3N120 HPG3N160 HPG3P120 HPG3P160 HPG3U120 HPG3U160 HPG3X120 HPG3X160 HPG4F160 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 HNF463 HNF463J HNF464 HNF464J HNF661J HNF661S HNF662J HNF662S HNF663J HNF663S HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-14 3-14 3-14 3-14 3-14 3-14 3-14 3-14 3-14 3-14 HPG4N120 HPG4N160 HPG4P120 HPG4P160 HPG4U120 HPG4U160 HPG4X120 HPG4X160 HPLE HPLEB HNF664J HNF664S HNG2B100L HNG2B120L HNG2B800L HNG2B900L HNG2F120 HNG3B100L HNG3B120L HNG3B800L HDSS HDSS 3-14 3-14 6-117 6-117 6-117 6-117 6-117 6-117 6-117 6-117 HNG3B900L HNG3D100L HNG3D120L HNG3D800L HNG3E100L HNG3E120L HNG3E800L HNG3F120 HNG3F120 HNG3F120 Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page 1-16 1-16 6-87 1-16 6-87 1-16 1-16 1-16 1-16 1-16 JD63B250 JD63B300 JD63B350 JD63B400 JD63F400 JD63T200 JD63T200 JD63T200 JD63T225 JD63T225 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-40 6-40 6-40 6-40 6-40 6-40 6-41 6-41 6-40 6-41 LBRA25D LBRD1 LBRH10 LBRH2 LBRH3 LBRH4 LBRH5 LBRH6 LBRH7 LBRH8 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 MCCB 6-86 MCCB 6-86 I1224L1125CU I1224L1200CU I1224L3125CU I1224L3200CU I1624L1125CU I1632L1200CU I1836L3200CU I2040L1200CU I2442L3200CU I3040L1125CU RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-16 1-16 1-16 1-16 1-16 1-16 1-16 1-16 1-16 1-16 JD63T225 JD63T250 JD63T250 JD63T250 JD63T250 JD63T250 JD63T250 JD63T300 JD63T300 JD63T300 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-41 6-40 6-41 6-41 6-44 6-45 6-45 6-40 6-41 6-41 LBRH9 LBRP25 LBRP25D LBRS040 LBRS050 LBRS055 LBRS080 LBRS120 LBRS180 LBRS305 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 HPLF HPLF HPLG HPLL HPLL HPLM HPLP HPLP HPS3S160 HPXD63B120 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-136 6-136 6-86 6-137 6-137 6-137 6-137 6-137 6-123 6-59 I3040L1200CU I3042L3200CU I4040L1200CU I4242L1225CU I4242L3225CU ICGK IGK IMK1 IPBF IPBF RESI RESI RESI RESI RESI UNPB UNPB UNPB MCCB MCCB 1-16 1-16 1-16 1-16 1-16 10-11 10-11 10-11 6-132 6-132 JD63T300 JD63T300 JD63T300 JD63T350 JD63T350 JD63T350 JD63T350 JD63T350 JD63T350 JD63T400 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-44 6-45 6-45 6-40 6-41 6-41 6-44 6-45 6-45 6-40 LBT3040 LBT3060 LBT3080 LBT3100 LBT4040 LBTCP1 LBTCP2 LBTCP3 LD1E100 LD62B250 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS MCCB MCCB 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 6-82 6-44 6-117 6-118 6-118 6-118 6-118 6-118 6-118 6-117 6-118 6-118 HPXD63B140 HPXD63B160 HQ2100BH HQ2125BH HQ2150BH HQ2175BH HQ2200BH HQ2225BH HQJ23B100H HQJ23B110H MCCB MCCB RESI RESI RESI RESI RESI RESI MCCB MCCB 6-59 6-59 1-29 1-29 1-29 1-29 1-29 1-29 6-28 6-28 IPBM IPBM IPBM IPBP IPBP IR0816L1200TR IR1224L1125 IR1632L1125 IR2040L1125CU IR2040L1200CU MCCB MCCB MCCB MCCB MCCB RESI RESI RESI RESI RESI 6-133 6-133 6-133 6-133 6-133 1-16 1-16 1-16 1-16 1-16 JD63T400 JD63T400 JD63T400 JD63T400 JD63T400 JD6HBL JD6HPL JG03579 JG04012 JG0401S MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-41 6-41 6-44 6-45 6-45 6-86 6-86 6-104 6-104 6-104 LD62B300 LD62B350 LD62B400 LD62B450 LD62B500 LD62B600 LD62F600 LD62T450 LD62T450 LD62T500 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-44 6-44 6-44 6-44 6-44 6-44 6-44 6-44 6-45 6-44 HNG3N100L HNG3N120L HNG3N800L HNG3P100L HNG3P120L HNG3P800L HNG3U100L HNG3U120L HNG3U800L HNG3X100L 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 HQJ23B125H HQJ23B150H HQJ23B175H HQJ23B200H HQJ23B225H HQN2150 HQN2150R HQN2175 HQN2175R HQN2200 MCCB MCCB MCCB MCCB MCCB RESI RESI RESI RESI RESI 6-28 6-28 6-28 6-28 6-28 1-29 1-29 1-29 1-29 1-29 IR2440L1200 IR3040L1125 IR3040L1200CU IR4040L1200CU IR4242L1225CU J6N1 J6N1 J6N12 J6N12 J6N3R RESI RESI RESI RESI RESI MCCB 1-16 1-16 1-16 1-16 1-16 5-8 6-41 5-13 6-41 5-10 JG0401SC JG0403R JG0403RC JXD22B200 JXD22B225 JXD22B250 JXD22B300 JXD22B350 JXD22B400 JXD22S400A MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-104 6-104 6-104 6-40 6-40 6-40 6-40 6-40 6-40 6-72 LD62T500 LD62T600 LD62T600 LD63B250 LD63B300 LD63B350 LD63B400 LD63B450 LD63B500 LD63B600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-45 6-44 6-45 6-44 6-44 6-44 6-44 6-44 6-44 6-44 HNG3X120L HNG3X800L HNG4F120 HNG4N100L HNG4N120L HNG4N800L HNG4P100L HNG4P120L HNG4P800L HNG4U100L 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 HQN2200R “HR2, HR6” “HR2, HR6” HR21 HR21 HR21 HR612 HR612 HR612 HR62 RESI 1-29 NEMA 16-87 NEMA 16-93 HDSS 3-17 HDSS 3-30 HDSS 4-8 HDSS 3-17 HDSS 3-30 HDSS 4-8 HDSS 3-17 J6N3R JD62B200 JD62B225 JD62B250 JD62B300 JD62B350 JD62B400 JD62F400 JD62T200 JD62T200 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-41 6-40 6-40 6-40 6-40 6-40 6-40 6-40 6-40 6-41 JXD23B200 JXD23B225 JXD23B250 JXD23B300 JXD23B350 JXD23B400 JXD23S400A JXD62B200 JXD62B225 JXD62B250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-40 6-40 6-40 6-40 6-40 6-40 6-72 6-40 6-40 6-40 LD63F600 LD63T450 LD63T450 LD63T500 LD63T500 LD63T500 LD63T600 LD6N1 LD6N1 LD6N12 MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-44 6-44 6-45 6-44 6-45 6-45 6-44 5-8 6-45 5-13 HNG4U120L HNG4U800L HNG4X100L HNG4X120L HNG4X800L HNM3M120 HNS2S120 HNS3S120 HNXD63B100 HNXD63B120 HR62 HR62 HR63 HR63 HR63 HR64 HR64 HR64 HR656 HR656 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 3-30 4-8 3-17 3-30 4-8 3-17 3-30 4-8 3-17 4-8 JD62T200 JD62T225 JD62T225 JD62T225 JD62T250 JD62T250 JD62T250 JD62T250 JD62T250 JD62T250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-41 6-40 6-41 6-41 6-40 6-41 6-41 6-44 6-45 6-45 JXD62B300 JXD62B350 JXD62B400 JXD62H400 JXD63B200 JXD63B225 JXD63B250 JXD63B300 JXD63B350 JXD63B400 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-40 6-40 6-40 6-66 6-40 6-40 6-40 6-40 6-40 6-40 LD6N12 LD6N3R LD6N3R LD6SS4 LD6SS4 LD6SS4 LDG2B050L LDG2B060L LDG2B070L LDG2B080L MCCB MCCB MCCB MCCB MCCB MCCB 6-118 6-118 6-118 6-118 6-118 6-124 6-123 6-123 6-56 6-56 HNXD63B900 HP61 HP61 HP62 HP62 HP63 HP63 HPD63B120 HPD63B140 HPD63B160 MCCB HDSS HDSS HDSS HDSS HDSS HDSS MCCB MCCB MCCB 6-56 3-18 4-9 3-18 4-9 3-18 4-9 6-59 6-59 6-59 HRD63B160 HRD63B180 HRD63B200 HRD63F200 HRXD63B160 HRXD63B180 HRXD63B200 HSBE HT23 HT23 MCCB MCCB MCCB MCCB MCCB MCCB MCCB HDSS HDSS 6-62 6-62 6-62 6-62 6-62 6-62 6-62 6-87 3-17 3-30 JD62T300 JD62T300 JD62T300 JD62T300 JD62T300 JD62T300 JD62T350 JD62T350 JD62T350 JD62T350 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-40 6-41 6-41 6-44 6-45 6-45 6-40 6-41 6-41 6-44 JXD63H400 JXD63L400 JXD63S400A K KCC KCC KT KTT LBR3025 LBR3025D MCCB MCCB MCCB NEMA NEMA NEMA NEMA NEMA HDSS HDSS 6-66 6-66 6-72 16-84 16-151 16-152 16-78 16-89 4-4 4-4 LDG2B090L LDG2B100L LDG2B110L LDG2B125L LDG2B150L LDG2F150 LDG3B050L LDG3B060L LDG3B070L LDG3B080L HPD63F160 HPG3B120 HPG3B140 HPG3B160 HPG3D120 HPG3D160 HPG3E120 HPG3E160 HPG3F160 HPG3F160 MCCB 6-59 6-120 6-120 6-120 6-121 6-121 6-121 6-121 6-120 6-121 HT23 HT24 HT24 HT24 HT63 HT63 HT63 HT64 HT64 HT64 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-8 3-17 3-30 4-8 3-17 3-30 4-8 3-17 3-30 4-8 JD62T350 JD62T350 JD62T400 JD62T400 JD62T400 JD62T400 JD62T400 JD62T400 JD63B200 JD63B225 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-45 6-45 6-40 6-41 6-41 6-44 6-45 6-45 6-40 6-40 LBR3040 LBR3060 LBR3080 LBR3100 LBR4040 LBRA1 LBRA1 LBRA2 LBRA2 LBRA25 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-4 4-4 4-4 4-4 4-4 3-33 4-4 3-33 4-4 4-4 LDG3B090L LDG3B100L LDG3B110L LDG3B125L LDG3B150L LDG3D060L LDG3D100L LDG3D150L LDG3E060L LDG3E100L Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MCCB MCCB 6-45 5-10 6-45 5-12 6-41 6-45 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-98 6-98 6-98 6-98 6-98 19-9 PRODUCT INDEX RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 19 I0202L1200 I0204ML1125 I0204ML1125 I0303ML3100 I0303ML3100 I0408ML1125 I0816L1200CT I0816ML1125CU I0816ML1125CUSP I1220L1200CT Product Index Catalog Number PRODUCT INDEX 19 LDG3E150L LDG3F150 LDG3F150 LDG3F150 LDG3N060L LDG3N100L LDG3N150L LDG3P060L LDG3P100L LDG3P150L Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page 6-98 6-97 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 LFG4B200L LFG4B225L LFG4B250L LFG4F250 LFS3S250L LG06012 LG0601S LG0603R LG0604S LG06079 6-101 6-101 6-101 6-101 6-123 6-108 6-108 6-108 6-108 6-108 LMD63B600 LMD63B700 LMD63B800 LMD63F800 LMD63T500 LMD63T500 LMD63T600 LMD63T600 LMD63T700 LMD63T700 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-48 6-48 6-48 6-48 6-48 6-49 6-48 6-49 6-48 6-49 LNG4P100L LNG4P120L LNG4P800L LNG4U100L LNG4U120L LNG4U800L LNG4X100L LNG4X120L LNG4X800L LNS3S120 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-123 MBK225 MBK225A MBK225A MBK225A MBKBC3 MBKBL1 MBKBL3 MBKED1 MBKED3 MBKED3100 RESI RESI RESI RESI UNPB UNPB UNPB UNPB UNPB MCCB 1-29 1-29 1-35 1-8 10-11 10-11 10-11 10-11 10-11 10-13 LDG3U060L LDG3U100L LDG3U150L LDG3X060L LDG3X100L LDG3X150L LDG4B050L LDG4B060L LDG4B070L LDG4B080L 6-98 6-98 6-98 6-98 6-98 6-98 6-97 6-97 6-97 6-97 LJG2B250L LJG2B300L LJG2B350L LJG2B400L LJG2F400 LJG3B250L LJG3B300L LJG3B350L LJG3B400L LJG3D250L 6-105 6-105 6-105 6-105 MCCB 6-105 6-105 6-105 6-105 6-105 6-106 LMD63T800 LMD63T800 LMG2B600L LMG2B700L LMG2B800L LMG2F800 LMG3B600L LMG3B700L LMG3B800L LMG3D600L MCCB MCCB 6-48 6-49 6-113 6-113 6-113 6-113 6-113 6-113 6-113 6-114 LPG3B120 LPG3B140 LPG3B160 LPG3D120 LPG3D160 LPG3E120 LPG3E160 LPG3F160 LPG3F160 LPG3F160 6-120 6-120 6-120 6-121 6-121 6-121 6-121 6-120 6-121 6-121 MBKED3125 MBKFD1 MBKFD3 MBKFD3150 MBKFD3175 MBKFD3200 MBKFD3225 MBKFD3250 MBKJD1 MBKJD1300 MCCB UNPB UNPB MCCB MCCB MCCB MCCB MCCB UNPB MCCB 10-13 10-11 10-11 10-13 10-13 10-13 10-13 10-13 10-11 10-13 LDG4B090L LDG4B100L LDG4B110L LDG4B125L LDG4B150L LDG4F150 LDP302 LDP304 LDP306 LDP308 6-97 6-97 6-97 6-97 6-97 6-97 14-50 14-50 14-50 14-50 LJG3D400L LJG3E250L LJG3E400L LJG3F400 LJG3F400 LJG3F400 LJG3N250L LJG3N400L LJG3P250L LJG3P400L 6-106 6-106 6-106 MCCB 6-105 MCCB 6-106 MCCB 6-106 6-106 6-106 6-106 6-106 LMG3D800L LMG3E600L LMG3E800L LMG3F800 LMG3F800 LMG3F800 LMG3N600L LMG3N800L LMG3P600L LMG3P800L 6-114 6-114 6-114 6-113 6-114 6-114 6-114 6-114 6-114 6-114 LPG3N120 LPG3N160 LPG3P120 LPG3P160 LPG3U120 LPG3U160 LPG3X120 LPG3X160 LPG4F160 LPG4N120 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 MBKJD1400 MBKJD3 MBKJD3300 MBKJD3400 MBKNB1 MBKNB100 MBKNB110 MBKNB125 MBKNB3 MBKQJ1 MCCB UNPB MCCB MCCB UNPB LDP310 LDP313 LDP316 LDP4024 LDP4044 LDP4064 LDP4084 LDP4104 LDU-100 LE 14-50 14-50 14-50 14-50 14-50 14-50 14-50 14-50 6-79 NEMA 16-69 LJG3U250L LJG3U400L LJG3X250L LJG3X400L LJG4B250L LJG4B300L LJG4B350L LJG4B400L LJG4F400 LJS3S400 6-106 6-106 6-106 6-106 6-105 6-105 6-105 6-105 6-105 6-123 LMG3U600L LMG3U800L LMG3X600L LMG3X800L LMG4F800 LMG4N600L LMG4N800L LMG4P600L LMG4P800L LMG4U600L 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 LPG4N160 LPG4P120 LPG4P160 LPG4U120 LPG4U160 LPG4X120 LPG4X160 LPS3S160 LXD62B450 LXD62B500 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-123 MCCB 6-44 MCCB 6-44 MBKQJ1125 MBKQJ1125H MBKQJ1150 MBKQJ1150H MBKQJ1175 MBKQJ1175H MBKQJ1200 MBKQJ1200H MBKQJ1225 MBKQJ1225H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 10-13 10-13 10-13 10-13 10-13 10-13 10-13 10-13 10-13 10-13 LE LE LE LF111N LF111NR LF211N LF211NR LFG2B100L LFG2B110L LFG2B125L NEMA 16-70 NEMA 16-87 NEMA 16-93 GDSS 3-6 GDSS 3-6 GDSS 3-6 GDSS 3-6 6-101 6-101 6-101 LKB4 LKB6 LKB8 LKF4 LKF6 LLG2B400L LLG2B500L LLG2B600L LLG2F600 LLG3B400L SWBD SWBD SWBD SWBD SWBD 12-22 12-22 12-22 12-22 12-22 6-109 6-109 6-109 MCCB 6-109 6-109 LMG4U800L LMG4X600L LMG4X800L LMS3S800 LMXD62B600 LMXD62B700 LMXD62B800 LMXD63A800 LMXD63B500 LMXD63B600 6-114 6-114 6-114 6-123 6-48 6-48 6-48 6-66 6-48 6-48 LXD62B600 LXD62L600 LXD63B450 LXD63B500 LXD63B600 LXD63H600 LXD63L600 LXD63S600A LXX-14 LXX-20 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-44 6-66 6-44 6-44 6-44 6-66 6-66 6-72 10-69 10-69 MBKQJ3 MBKQJ3125 MBKQJ3125H MBKQJ3150 MBKQJ3150H MBKQJ3175 MBKQJ3175H MBKQJ3200 MBKQJ3200H MBKQJ3225 UNPB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 10-11 10-13 10-13 10-13 10-13 10-13 10-13 10-13 10-13 10-13 LFG2B150L LFG2B175L LFG2B200L LFG2B225L LFG2B250L LFG2F250 LFG3B100L LFG3B110L LFG3B125L LFG3B150L 6-101 6-101 6-101 6-101 6-101 MCCB 6-101 6-101 6-101 6-101 6-101 LLG3B500L LLG3B600L LLG3D400L LLG3D600L LLG3E400L LLG3E600L LLG3F600 LLG3F600 LLG3F600 LLG3N400L 6-109 6-109 6-110 6-110 6-110 6-110 MCCB 6-109 MCCB 6-110 MCCB 6-110 6-110 LMXD63B700 LMXD63B800 LMXD63L800 LMXD63S800A LN1E100 LNF222R LNG2B100L LNG2B120L LNG2B800L LNG2B900L 6-48 6-48 6-66 6-72 6-82 3-6 6-117 6-117 6-117 6-117 LXX-26 LXX-32 LXX-38 LXX-41 LXX-44 LXX50-F LXX-53 LXX-56 LXX-62 LXX-65 10-69 10-69 10-69 10-69 10-69 10-69 10-69 10-69 10-69 10-69 MBKQJ3225H MBPG1600 MBPG1600 MBPG1601 MBPG1601 MBR9302 MBR9302 MBR9302 MBR9302 MBR9302 MCCB 10-13 6-120 6-133 6-120 6-133 MCCB 6-60 MCCB 6-62 MCCB 6-62 MCCB 6-62 MCCB 6-62 LFG3B175L LFG3B200L LFG3B225L LFG3B250L LFG3D100L LFG3D150L LFG3D250L LFG3E100L LFG3E150L LFG3E250L 6-101 6-101 6-101 6-101 6-102 6-102 6-102 6-102 6-102 6-102 LLG3N600L LLG3P400L LLG3P600L LLG3U400L LLG3U600L LLG3X400L LLG3X600L LLS3S600 LMAP1600 LMAP1600 6-110 6-110 6-110 6-110 6-110 6-110 6-110 6-123 6-120 6-133 LNG2F120 LNG3B100L LNG3B120L LNG3B800L LNG3B900L LNG3D100L LNG3D120L LNG3D800L LNG3E100L LNG3E120L 6-117 6-117 6-117 6-117 6-117 6-118 6-118 6-118 6-118 6-118 LXX-68 LXX-74 LXX-80 LXX-86 LXXP-T MB120 MB9301 MB9301 MB9301 MB9301 MCCB MCCB MCCB MCCB MCCB 10-69 10-69 10-69 10-69 10-69 6-87 6-59 6-59 6-59 6-60 MC0408B1150RT MC0408B1150T MC0408B1200RT MC0408B1200T MC0408B1400RLTM MC0606L1200R MC0606L1200RA MC0606L1200RJB MC0816B1150CT MC0816B1150RCT RESI RESI RESI RESI RESI 2-20 2-20 2-20 2-20 2-21 2-20 2-20 2-20 2-20 2-20 LFG3F250 LFG3F250 LFG3F250 LFG3N100L LFG3N150L LFG3N250L LFG3P100L LFG3P150L LFG3P250L LFG3U100L MCCB 6-101 MCCB 6-102 MCCB 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 LMD1 LMD1 LMD12 LMD12 LMD3R LMD3R LMD62B500 LMD62B600 LMD62B700 LMD62B800 MCCB MCCB MCCB 5-8 6-49 5-13 6-49 5-10 6-49 6-48 6-48 6-48 6-48 LNG3E800L LNG3F120 LNG3F120 LNG3F120 LNG3N100L LNG3N120L LNG3N800L LNG3P100L LNG3P120L LNG3P800L 6-118 6-117 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 MB9301 MB9301 MB9301 MB9301 MBK100 MBK100A MBK100A MBK100A MBK125 MBK125A MCCB MCCB MCCB MCCB RESI RESI RESI RESI RESI RESI 6-62 6-62 6-62 6-62 1-29 1-29 1-35 1-8 1-29 1-29 MC0816B1150RTH MC0816B1150T MC0816B1150TH MC0816B1200CT MC0816B1200FCTM MC0816B1200RCT MC0816B1200RT MC0816B1200RTH MC0816B1200SCTM MC0816B1200T RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 2-21 2-21 2-21 2-20 2-22 2-20 2-21 2-21 2-22 2-21 LFG3U150L LFG3U250L LFG3X100L LFG3X150L LFG3X250L LFG4B100L LFG4B110L LFG4B125L LFG4B150L LFG4B175L 6-102 6-102 6-102 6-102 6-102 6-101 6-101 6-101 6-101 6-101 LMD62F800 LMD62T500 LMD62T500 LMD62T600 LMD62T600 LMD62T700 LMD62T700 LMD62T800 LMD62T800 LMD63B500 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-48 6-48 6-49 6-48 6-49 6-48 6-49 6-48 6-49 6-48 LNG3U100L LNG3U120L LNG3U800L LNG3X100L LNG3X120L LNG3X800L LNG4F120 LNG4N100L LNG4N120L LNG4N800L 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 MBK125A MBK125A MBK150 MBK150A MBK150A MBK150A MBK200 MBK200A MBK200A MBK200A RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-35 1-8 1-29 1-29 1-35 1-8 1-29 1-29 1-35 1-8 MC0816B1200TH MC0816B1350RLTM MC0816B1400RLTM MC1020B1100EY MC104BD MC10BD MC1212L1200FED MC1212L1200FED MC1224B1100CEY MC1224B1100FEC RESI RESI RESI 2-21 2-21 2-21 2-85 2-83 2-83 2-23 2-23 2-85 2-22 19-10 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB GDSS Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 10-13 10-11 10-13 10-13 10-11 10-13 10-13 10-13 UNPB 10-11 UNPB 10-11 RESI RESI RESI RESI RESG RESI RESI RESI Product Index Catalog Number MC1224B1100SEC MC1224B1125 MC1224B1125FEC MC1224B1125SEC MC1224MB1125R MC124BD MC12BD MC1632B1100FEC MC1632B1100SEC MC1632B1125FEC MC1830F3100CEY MC20 MC20 MC2040B1150 MC2040B1150R MC2040B1150RC MC2040B1150RJBC MC2040B1200 MC2040B1200FED MC2040B1200R Product Category RESI RESI RESI RESI RESI RESG RESI RESI RESI RESG RESG RESI RESI RESI RESI RESI RESI MC2040B1200RC MC2040B1200RJBC MC2040B1200SED MC2440B1200CEY MC2442B1200FEC MC2442B1200SEC MC2442B1225FEC MC2442B1225SEC MC2442B1250FE2 MC2442F3200CEY RESI RESI RESI MC3040B1200SECW MC3042B1200FED MC3042B1200SED MC3042B1225FED MC3042B1225SED MC3042B1250FE2 MC4040B1200SECW MC44BD MC4BD MC64BD RESI RESI RESI RESI RESI RESI RESI RESG RESI RESI RESI RESI RESI Page Catalog Number 2-22 2-21 2-22 2-22 2-21 2-83 2-83 2-22 2-22 2-22 MD63T800 MD63T800 MD63T800 MFCF036 MFCF048 MFCF060 MFCF072 MFCF084 MFCF096 MFCF120 2-85 2-41 2-41 2-21 2-21 2-20 2-20 2-21 2-23 2-21 Product Category Page MCCB MCCB MCCB Catalog Number Product Category Page 6-52 6-55 6-56 6-128 6-128 6-128 6-128 6-128 6-128 6-128 MI5404 MI5405 MI5406 MI5413 MI5444 MLKA1 MLKA1 MLKA3 MLKA3 MLKC1 MCCB MCCB MCCB MCCB MCCB UNPB UNPB UNPB UNPB UNPB MFCF144 MFCM036 MFCM036 MFCM048 MFCM048 MFCM060 MFCM060 MFCM072 MFCM072 MFCM084 6-128 6-128 6-129 6-128 6-129 6-128 6-129 6-128 6-129 6-128 MLKC3 MM0202B1125RJB MM0202B1125RJBX MM0202B1150 MM0202B1150R MM0202B1150RJB MM0202B1150RJBX MM0202B1200 MM0202B1200R MM0202B1200RJB UNPB 10-11 RESI 2-19 RESI 2-19 RESI 2-19 2-19 RESI 2-19 RESI 2-19 RESI 2-19 2-19 RESI 2-19 2-20 2-20 2-23 2-85 2-22 2-22 2-22 2-22 2-24 2-85 MFCM084 MFCM096 MFCM096 MFCM120 MFCM120 MFCM144 MFCM144 MFCP048 MFCP048 MFCP060 6-129 6-128 6-129 6-128 6-129 6-128 6-129 6-129 6-129 6-129 MM0202B1200RJBX MM0202F1100CEY MM0202F1100EY MM0202F1200CEY MM0202F1200EY MM0202L1100EY MM0202L1200CEY MM0202L1200EY MM0202ML1100S MM0202ML1125H MFCP060 MFCP072 MFCP072 MFCP084 MFCP084 MFCP096 MFCP096 MFCP120 MFCP120 MFCP144 6-129 6-129 6-129 6-129 6-129 6-129 6-129 6-129 6-129 6-129 MM0303F3100CEY MM0303F3100EY MM0303F3200CEY MM0303F3200EY MM0303L3100EY MM0303L3200CEY MM0303L3200EY MM0404L1400RLM MM0406B1200FEC MM0406B1200SEC RESI 6-87 6-87 6-87 6-87 6-87 10-11 10-12 10-11 10-12 10-11 Catalog Number MOMN6240 MRS MS14TB MS15TB MS17TB MS24TB MS25TB MS27TB MS44UBD MS44UTB MS4UBD MS64UBD MS6UBD MS84UBD MS8UBD MSE6 MSE6100 MSF6 MSF650 MSJ6 Product Category Page MCCB NEMA Catalog Number Product Category Page 6-90 16-7 2-9 2-9 2-9 2-9 2-9 2-9 2-83 2-9 N2250 N250 N250 N250 N250 N250 N250 N250 N25STD N32STD MCCB MCCB MCCB MCCB MCCB MCCB 2-83 2-83 2-83 2-83 2-83 6-87 6-87 6-87 6-87 6-87 NBK3 NBK4 NBK5 NBK6 ND62B100 ND62B120 ND62B800 ND62B900 ND62F120 ND62T100 UNPB 10-11 UNPB 10-11 10-11 10-11 MCCB 6-55 MCCB 6-55 MCCB 6-55 MCCB 6-55 MCCB 6-55 MCCB 6-55 ND62T120 ND62T900 ND63B100 ND63B800 ND63B900 ND63B900 ND63F120 ND63T100 ND63T100 ND63T120 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-55 6-55 6-55 6-55 6-55 6-55 6-55 6-55 6-56 6-55 MCCB MCCB MCCB 6-56 6-55 6-56 6-97 6-97 6-97 6-97 6-97 6-97 6-97 RESG RESG RESG RESI RESI 2-19 2-84 2-84 2-84 2-84 2-84 2-84 2-84 2-19 2-19 MSK2001 MSK2003 MSKE1 MSKE2 MSKE4 MSKF2 MSKF2 MSKF4 MSKF4 MSKG4 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 12-26 12-26 6-87 6-87 6-87 6-136 6-136 6-136 6-136 6-87 RESI RESI RESI 2-84 2-84 2-84 2-84 2-84 2-84 2-84 2-19 2-22 2-22 MSKL4 MSKL4 MSKM4 MSKP4 MSKP4 MSLMD MSMN MSPR6 MSQJ MT MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB NEMA 6-137 6-137 6-137 6-137 6-137 6-87 6-87 6-87 6-87 16-8 ND63T120 ND63T900 ND63T900 NDG2B050L NDG2B060L NDG2B070L NDG2B080L NDG2B090L NDG2B100L NDG2B110L 2-22 2-22 2-19 2-19 2-19 2-82 2-82 2-82 2-82 2-82 MTA MTC08 MTC15 MTC25 MTC50 MTCSB08 MTCSB15 MTCSB25 MTCSB50 MTG MCCB MCCB MCCB MCCB MCCB 6-80 6-80 6-80 6-80 6-80 6-80 6-80 6-80 6-80 NEMA 16-77 NDG2B125L NDG2B150L NDG2F150 NDG3B050L NDG3B060L NDG3B070L NDG3B080L NDG3B090L NDG3B100L NDG3B110L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 5-9 5-11 5-12 5-13 5-4 5-7 5-9 6-37 6-64 6-64 RESG 2-22 2-23 2-23 2-23 2-23 2-24 2-22 2-83 2-83 2-83 MC6BD MC84BD MC8BD MCB12 MCS603R MCS606R MCS610R MCS620R MCSAK116 MCSAK116 RESG RESG RESI HDSS HDSS HDSS HDSS HDSS HDSS 2-83 2-83 2-83 1-35 4-11 4-11 4-11 4-11 4-12 4-12 MFCP144 MFHM3R MFHM3R MFHM3R MFHM3RB MFHM3RB MFHM3RB MFHM3RS MFHM3RS MFHM3RSB 6-129 6-128 6-128 6-129 6-128 6-128 6-129 6-128 6-128 6-128 MM0406L1125FEC MM0406L1125SEC MM0406L1200H MM0406L1200RH MM0406L1200RHJB MMBMT1 MMBMT2 MMCVR1 MMCVR1R MMCVR2 MCSAK126 MCSAK126 MCSAK216 MCSAK216 MCSAK226 MCSAK226 MCSAKL136 MCSAKL136 MCSAKL236 MCSAKL236 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 4-12 MFHM3RSB MFHM3RSB MFHM4X MFHM4X MFHM4X MFHP3RS MFHP3RS MFHP3RS MFHP3RSB MFHP3RSB 6-128 6-129 6-128 6-128 6-129 6-129 6-129 6-129 6-129 6-129 MMCVR2R MMPK11 MMPK13 MMPK21 MMPK23 MMS MMSCK1 MMSCK2 MN6BL MN6PLD 2-82 2-82 2-82 2-82 2-82 NEMA 16-150 2-82 2-82 MCCB 6-86 MCCB 6-86 MTRPB MTRPM MTRPN MTRPR MTRPY MTZ MXD62B500 MXD62B600 MXD62B700 MXD62B800 MCCB MCCB MCCB MCCB MCCB MCCB 6-131 6-131 6-131 6-131 6-131 6-80 6-51 MCCB 6-51 MCCB 6-51 MCCB 6-51 NDG3B125L NDG3B150L NDG3D060L NDG3D100L NDG3D150L NDG3E060L NDG3E100L NDG3E150L NDG3F150 NDG3F150 MCSAKR136 MCSAKR136 MCSAKR236 MCSAKR236 MD62B500 MD62B600 MD62B700 MD62B800 MD62F800 MD62T500 HDSS HDSS HDSS HDSS MCCB MCCB MCCB MCCB MCCB MCCB 4-12 4-12 4-12 4-12 6-51 6-51 6-51 6-51 6-51 6-51 MFHP4X MFHP4X MFKE3 MFKE4X3 MFKF3R MFKL3R MFKM3R MFKP3RS MFKP3RS MFMF 6-129 6-129 6-89 6-89 6-128 6-128 6-129 6-129 6-129 6-128 MND61 MND61 MND61 MND61 MND612 MND612 MND612 MND612 MND63 MND63 MCCB MCCB MCCB MCCB 5-8 6-51 6-53 6-55 5-13 6-51 6-53 6-55 5-10 6-51 MXD63A800 MXD63B500 MXD63B600 MXD63B700 MXD63B800 MXD63H800 MXD63L800 MXD63S800A N02SJD N03SJD MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-66 6-51 6-51 6-51 6-51 6-66 6-66 6-72 6-42 6-42 NDG3F150 NDG3N060L NDG3N100L NDG3N150L NDG3P060L NDG3P100L NDG3P150L NDG3U060L NDG3U100L NDG3U150L MD62T500 MD62T600 MD62T600 MD62T700 MD62T700 MD62T800 MD62T800 MD62T800 MD63B500 MD63B600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-52 6-51 6-52 6-51 6-52 6-51 6-52 6-55 6-51 6-51 MFML MFMM MFMP MFMP MFSFA1 MFSFA2 MFSLA1 MFSLA2 MFSPA1 MFSPA1 6-128 6-129 6-129 6-129 6-128 6-128 6-128 6-128 6-129 6-129 MND63 MND63 MOE6120 MOE6240 MOF6024DC MOF6048DC MOF6120 MOF6125DC MOF6240 MOJ6024DC MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-55 6-90 6-90 6-90 6-90 6-90 6-90 6-90 6-90 N03SJD N04SJD N04SJD N05SLD N06SLD N06SMDA N07SMDA N08SMDA N08SMDA N10SNDA MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-46 6-42 6-46 6-46 6-46 6-53 6-53 6-53 6-57 6-57 NDG3X060L NDG3X100L NDG3X150L NDG4B050L NDG4B060L NDG4B070L NDG4B080L NDG4B090L NDG4B100L NDG4B110L 6-98 6-98 6-98 6-97 6-97 6-97 6-97 6-97 6-97 6-97 MD63B700 MD63B800 MD63F800 MD63T500 MD63T500 MD63T600 MD63T600 MD63T600 MD63T700 MD63T800 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-51 6-51 6-51 6-51 6-52 6-51 6-51 6-52 6-52 6-51 MFSPA1 MFSPA2 MFSPA2 MFSPA2 MG0801S MG0803R MG1 MG1D MG1D MI5404 6-129 6-129 6-129 6-129 6-112 6-112 10-50 10-61 12-26 6-87 MOJ6048DC MOJ6120 MOJ6125DC MOJ6240 MOLMD6024DC MOLMD6048DC MOLMD6120 MOLMD6125DC MOLMD6240 MOMN6120 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-90 6-90 6-90 6-90 6-90 6-90 6-90 6-90 6-90 6-90 N12SNDA N14SPD N16SPD N2000 N2000 N2000 N2000 N20STD N2250 N2250 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-57 6-60 6-60 5-6 5-7 5-7 5-9 6-64 5-4 5-7 NDG4B125L NDG4B150L NDG4F150 NEB1B015B NEB1B020B NEB1B025B NEB1B030B NEB1B035B NEB1B040B NEB1B045B 6-97 6-97 6-97 6-24 6-24 6-24 6-24 6-24 6-24 6-24 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-97 6-97 6-98 6-98 6-98 6-98 6-98 6-98 6-97 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 6-98 19-11 PRODUCT INDEX Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MCCB 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 6-97 19 PBSB PBSB PBSB MCCB RESI RESI RESI RESI Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number Product Category Page NEB1B050B NEB1B060B NEB1B070B NEB1B080B NEB1B090B NEB1B100B NEB1B110B NEB1B125B NEB2B015B NEB2B020B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 NEG4B050L NEG4B060L NEG4B070L NEG4B080L NEG4B090L NEG4B100L NEG4B110L NEG4B125L NF355HDTK NF355SSDTK NEB2B025B NEB2B030B NEB2B035B NEB2B040B NEB2B045B NEB2B050B NEB2B060B NEB2B070B NEB2B080B NEB2B090B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 NF454DTK NF454SSDTK NF455DTK NF456DTK NF457DTK NFG2B100L NFG2B110L NFG2B125L NFG2B150L NFG2B175L HDSS HDSS HDSS HDSS HDSS NEB2B100B NEB2B110B NEB2B125B NEB3B015B NEB3B020B NEB3B025B NEB3B030B NEB3B035B NEB3B040B NEB3B045B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 NEB3B050B NEB3B060B NEB3B070B NEB3B080B NEB3B090B NEB3B100B NEB3B110B NEB3B125B NEG1B015L NEG1B020L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB NEG1B025L NEG1B030L NEG1B035L NEG1B040L NEG1B045L NEG1B050L NEG1B060L NEG1B070L NEG1B080L NEG1B090L NEG1B100L NEG1B110L NEG1B125L NEG2B015L NEG2B020L NEG2B025L NEG2B030L NEG2B035L NEG2B040L NEG2B045L Catalog Number Catalog Number Product Category Page Catalog Number Product Category Page 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 3-29 3-29 NGB2B020B NGB2B025B NGB2B030B NGB2B035B NGB2B040B NGB2B045B NGB2B050B NGB2B060B NGB2B070B NGB2B080B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 NJG2B250L NJG2B300L NJG2B350L NJG2B400L NJG2F400 NJG3B250L NJG3B300L NJG3B350L NJG3B400L NJG3D250L 6-105 6-105 6-105 6-105 MCCB 6-105 6-105 6-105 6-105 6-105 6-106 NNG2B100L NNG2B120L NNG2B800L NNG2B900L NNG2F120 NNG3B100L NNG3B120L NNG3B800L NNG3B900L NNG3D100L 6-117 6-117 6-117 6-117 6-117 6-117 6-117 6-117 6-117 6-118 3-29 3-29 3-29 3-29 3-29 6-101 6-101 6-101 6-101 6-101 NGB2B090B NGB2B100B NGB2B110B NGB2B125B NGB3B015B NGB3B020B NGB3B025B NGB3B030B NGB3B035B NGB3B040B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 NJG3D400L NJG3E250L NJG3E400L NJG3F400 NJG3F400 NJG3F400 NJG3N250L NJG3N400L NJG3P250L NJG3P400L 6-106 6-106 6-106 MCCB 6-105 MCCB 6-106 MCCB 6-106 6-106 6-106 6-106 6-106 NNG3D120L NNG3D800L NNG3E100L NNG3E120L NNG3E800L NNG3F120 NNG3F120 NNG3F120 NNG3N100L NNG3N120L 6-118 6-118 6-118 6-118 6-118 6-117 6-118 6-118 6-118 6-118 NFG2B200L NFG2B225L NFG2B250L NFG2F250 NFG3B100L NFG3B110L NFG3B125L NFG3B150L NFG3B175L NFG3B200L 6-101 6-101 6-101 MCCB 6-101 6-101 6-101 6-101 6-101 6-101 6-101 NGB3B045B NGB3B050B NGB3B060B NGB3B070B NGB3B080B NGB3B090B NGB3B100B NGB3B110B NGB3B125B NGG1B015L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-30 NJG3U250L NJG3U400L NJG3X250L NJG3X400L NJG4B250L NJG4B300L NJG4B350L NJG4B400L NJG4F400 NJJ2B250L 6-106 6-106 6-106 6-106 6-105 6-105 6-105 6-105 6-105 6-105 NNG3N800L NNG3P100L NNG3P120L NNG3P800L NNG3U100L NNG3U120L NNG3U800L NNG3X100L NNG3X120L NNG3X800L 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-24 6-32 6-32 NFG3B225L NFG3B250L NFG3D100L NFG3D150L NFG3D250L NFG3E100L NFG3E150L NFG3E250L NFG3F250 NFG3F250 6-101 6-101 6-102 6-102 6-102 6-102 6-102 6-102 MCCB 6-101 MCCB 6-102 NGG1B020L NGG1B025L NGG1B030L NGG1B035L NGG1B040L NGG1B045L NGG1B050L NGG1B060L NGG1B070L NGG1B080L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 NJJ2B300L NJJ2B350L NJJ2B400L NJJ3B250L NJJ3B300L NJJ3B350L NJJ3B400L NLG2B400L NLG2B500L NLG2B600L 6-105 6-105 6-105 6-105 6-105 6-105 6-105 6-109 6-109 6-109 NNG4F120 NNG4N100L NNG4N120L NNG4N800L NNG4P100L NNG4P120L NNG4P800L NNG4U100L NNG4U120L NNG4U800L 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 6-118 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 NFG3F250 NFG3N100L NFG3N150L NFG3N250L NFG3P100L NFG3P150L NFG3P250L NFG3U100L NFG3U150L NFG3U250L MCCB 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 6-102 NGG1B090L NGG1B100L NGG1B110L NGG1B125L NGG2B015L NGG2B020L NGG2B025L NGG2B030L NGG2B035L NGG2B040L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 NLG2F600 NLG3B400L NLG3B500L NLG3B600L NLG3D400L NLG3D600L NLG3E400L NLG3E600L NLG3F600 NLG3F600 MCCB 6-109 6-109 6-109 6-109 6-110 6-110 6-110 6-110 MCCB 6-109 MCCB 6-110 NNG4X100L NNG4X120L NNG4X800L NPG3B120 NPG3B140 NPG3B160 NPG3D120 NPG3D160 NPG3E120 NPG3E160 6-118 6-118 6-118 6-120 6-120 6-120 6-121 6-121 6-121 6-121 MCCB MCCB MCCB 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 NFG3X100L NFG3X150L NFG3X250L NFG4B100L NFG4B110L NFG4B125L NFG4B150L NFG4B175L NFG4B200L NFG4B225L 6-102 6-102 6-102 6-101 6-101 6-101 6-101 6-101 6-101 6-101 NGG2B045L NGG2B050L NGG2B060L NGG2B070L NGG2B080L NGG2B090L NGG2B100L NGG2B110L NGG2B125L NGG3B015L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 NLG3F600 NLG3N400L NLG3N600L NLG3P400L NLG3P600L NLG3U400L NLG3U600L NLG3X400L NLG3X600L NMG2B600L MCCB 6-110 6-110 6-110 6-110 6-110 6-110 6-110 6-110 6-110 6-113 NPG3F160 NPG3F160 NPG3F160 NPG3N120 NPG3N160 NPG3P120 NPG3P160 NPG3U120 NPG3U160 NPG3X120 6-120 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 NFG4B250L NFG4F250 NFR451DTK NFR452DTK NFR453DTK NFR454DTK NFR455DTK NFR456DTK NFR457DTK NG12012 6-101 6-101 3-29 3-29 3-29 3-29 3-29 3-29 3-29 6-116 NGG3B020L NGG3B025L NGG3B030L NGG3B035L NGG3B040L NGG3B045L NGG3B050L NGG3B060L NGG3B070L NGG3B080L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 6-30 NMG2B700L NMG2B800L NMG2F800 NMG3B600L NMG3B700L NMG3B800L NMG3D600L NMG3D800L NMG3E600L NMG3E800L 6-113 6-113 6-113 6-113 6-113 6-113 6-114 6-114 6-114 6-114 NPG3X160 NPG4F160 NPG4N120 NPG4N160 NPG4P120 NPG4P160 NPG4U120 NPG4U160 NPG4X120 NPG4X160 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 6-121 MCCB MCCB MCCB MCCB 6-30 6-30 6-30 6-30 6-138 6-138 6-138 6-138 6-138 6-138 NMG3F800 NMG3F800 NMG3F800 NMG3N600L NMG3N800L NMG3P600L NMG3P800L NMG3U600L NMG3U800L NMG3X600L 6-113 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 NSK400 NSK400 NSK600 NSK600 NXD62B100 NXD62B120 NXD62B900 NXD63B100 NXD63B120 NXD63B900 RESG RESG RESG RESG MCCB MCCB MCCB MCCB MCCB MCCB 2-74 2-81 2-74 2-81 6-55 6-55 6-55 6-55 6-55 6-55 6-139 6-139 6-139 6-139 6-139 6-139 6-139 6-139 6-139 6-139 NMG3X800L NMG4F800 NMG4N600L NMG4N800L NMG4P600L NMG4P800L NMG4U600L NMG4U800L NMG4X600L NMG4X800L 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 6-114 NXD63S120A OFCK620 OFCK620 OFCK620 OFCK620 OFCK661 OFCK661 OFCK661 OFCK661 OH9498 MCCB HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS MCCB 6-72 4-11 4-11 4-11 4-11 4-11 4-11 4-11 4-11 6-88 HDSS HDSS NEG2B050L NEG2B060L NEG2B070L NEG2B080L NEG2B090L NEG2B100L NEG2B110L NEG2B125L NEG3B015L NEG3B020L MCCB MCCB 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 NEG3B025L NEG3B030L NEG3B035L NEG3B040L NEG3B045L NEG3B050L NEG3B060L NEG3B070L NEG3B080L NEG3B090L MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 NG1201S NG1203R NG1D NG1D NGB1B015B NGB1B020B NGB1B025B NGB1B030B NGB1B035B NGB1B040B 6-116 6-116 PBSB 10-61 PBSB 12-26 MCCB 6-22 MCCB 6-22 MCCB 6-22 MCCB 6-22 MCCB 6-22 MCCB 6-22 NGG3B090L NGG3B100L NGG3B110L NGG3B125L NGSD060 NGSF100 NGSF100 NGSF150 NGSF150 NGSJ250 NEG3B100L NEG3B110L NEG3B125L NEG4B015L NEG4B020L NEG4B025L NEG4B030L NEG4B035L NEG4B040L NEG4B045L MCCB MCCB MCCB 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 6-32 NGB1B045B NGB1B050B NGB1B060B NGB1B070B NGB1B080B NGB1B090B NGB1B100B NGB1B110B NGB1B125B NGB2B015B MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB NGSJ250 NGSL400 NGSL400 NGSM600 NGSM600 NGSN800 NGSN800 NGSP120 NGSP120 NGSP160 19-12 Product Category Page HDSS HDSS HDSS HDSS HDSS HDSS HDSS 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 6-22 MCCB MCCB MCCB MCCB MCCB MCCB MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Product Index Catalog Number P137RT2B P137RTP P137TP P137U2B P137UP P137US P177RBS P17RBS P17US P1A18BL100ATS Product Category Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page 10-18 10-18 10-18 10-18 10-18 10-18 10-18 UNPB 10-10 UNPB 10-10 UNPB 10-10 P2C42FX250ATS P2C42JX400ATS P2C42LX600ATS P2C42ML125ATS P2C42ML250ATS P2C42ML400ATS P2C42ML600ATS P2C42NB125ATS P2C42QJ225ATS P2C54JX400ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P3B56ML600ATS P3B56ML800ATS P3B62FD250ATS P3B62JD400ATS P3B62LD600ATS P3B62ML250ATS P3B62ML400ATS P3B62ML600ATS P3B62ML800ATS P3B68FD250ATS 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 P3D74ML250ATS P3D74ML400ATS P3D74ML600ATS P3D74ML800ATS P3D80FD250ATS P3D80JD400ATS P3D80LD600ATS P3D80ML250ATS P3D80ML400ATS P3D80ML600ATS 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-18 10-18 10-10 10-10 10-10 10-10 10-18 10-18 10-18 10-18 P1E42MC400C P1E42ML125ATS P1E42ML250ATS P1E42ML400ATS P1E42NB125ATS P1F37UML P1F77RBS P1F7RTS P1F7TS P1F7US UNPB 10-10 10-18 10-18 10-18 10-18 RESG 1-40 RESG 1-40 RESG 1-40 RESG 1-40 RESG 1-40 P2C54LX600ATS P2C54ML400ATS P2C54ML600ATS P2E18BQ100ATS P2E18FX225ATS P2E18FX250ATS P2E18JX400ATS P2E18LX600ATS P2E18ML125ATS P2E18ML250ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P3B68JD400ATS P3B68LD600ATS P3B68ML250ATS P3B68ML400ATS P3B68ML600ATS P3B68ML800ATS P3B74FD250ATS P3B74JD400ATS P3B74LD600ATS P3B74ML250ATS 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 P3D80ML800ATS P3E56FD250ATS P3E56JD400ATS P3E56LD600ATS P3E56ML250ATS P3E56ML400ATS P3E56ML600ATS P3E56ML800ATS P3E62FD250ATS P3E62JD400ATS 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-18 10-18 10-18 10-18 10-10 10-10 10-10 10-10 10-18 10-18 P1X18MC250A P1X18MC250C P1X18MC400A P1X18MC400C P1X30MC250A P1X30MC250C P1X30MC400A P1X30MC400C P1X42MC250A P1X42MC250C UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 P2E18ML400ATS P2E18ML600ATS P2E18NB125ATS P2E30BQ100ATS P2E30FX225ATS P2E30FX250ATS P2E30JX400ATS P2E30LX600ATS P2E30ML125ATS P2E30ML250ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P3B74ML400ATS P3B74ML600ATS P3B74ML800ATS P3B80FD250ATS P3B80JD400ATS P3B80LD600ATS P3B80ML250ATS P3B80ML400ATS P3B80ML600ATS P3B80ML800ATS 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 P3E62LD600ATS P3E62ML250ATS P3E62ML400ATS P3E62ML600ATS P3E62ML800ATS P3E68FD250ATS P3E68JD400ATS P3E68LD600ATS P3E68ML250ATS P3E68ML400ATS 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-18 10-18 10-18 10-18 10-18 10-18 10-10 10-10 10-10 10-10 P1X42MC400A P1X42MC400C P2A18BL100ATS P2A18FX250ATS P2A18JX400ATS P2A18LX600ATS P2A18ML125ATS P2A18ML250ATS P2A18ML400ATS P2A18ML600ATS UNPB 10-10 UNPB 10-10 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P2E30ML400ATS P2E30ML600ATS P2E30NB125ATS P2E42BQ100ATS P2E42FX225ATS P2E42FX250ATS P2E42JX400ATS P2E42LX600ATS P2E42ML125ATS P2E42ML250ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P3BK1 P3C56FD250ATS P3C56JD400ATS P3C56LD600ATS P3C56ML250ATS P3C56ML400ATS P3C56ML600ATS P3C56ML800ATS P3C62FD250ATS P3C62JD400ATS PBSB 10-42 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 P3E68ML600ATS P3E68ML800ATS P3E74FD250ATS P3E74JD400ATS P3E74LD600ATS P3E74ML250ATS P3E74ML400ATS P3E74ML600ATS P3E74ML800ATS P3E80FD250ATS 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 P1A42ML125ATS P1A42ML250ATS P1A42ML400ATS P1A42NB125ATS P1A42QJ225ATS P1C18BL100ATS P1C18FX250ATS P1C18ML125ATS P1C18ML250ATS P1C18ML400ATS 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 P2A18NB125ATS P2A18QJ225ATS P2A30BL100ATS P2A30FX250ATS P2A30JX400ATS P2A30LX600ATS P2A30ML125ATS P2A30ML250ATS P2A30ML400ATS P2A30ML600ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P2E42ML400ATS P2E42ML600ATS P2E42NB125ATS P2E54JX400ATS P2E54LX600ATS P2E54ML400ATS P2E54ML600ATS P30EMS P37UP P37US 10-27 10-27 10-27 10-27 10-27 10-27 10-27 PILO 16-218 RESG 1-40 RESG 1-40 P3C62LD600ATS P3C62ML250ATS P3C62ML400ATS P3C62ML600ATS P3C62ML800ATS P3C68FD250ATS P3C68JD400ATS P3C68LD600ATS P3C68ML250ATS P3C68ML400ATS 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 P3E80JD400ATS P3E80LD600ATS P3E80ML250ATS P3E80ML400ATS P3E80ML600ATS P3E80ML800ATS P3F56FD250ATS P3F56JD400ATS P3F56LD600ATS P3F56ML250ATS 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 P1C18NB125ATS P1C18QJ225ATS P1C30BL100ATS P1C30FX250ATS P1C30JX400ATS P1C30ML125ATS P1C30ML250ATS P1C30ML400ATS P1C30NB125ATS P1C30QJ225ATS 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 P2A30NB125ATS P2A30QJ225ATS P2A42BL100ATS P2A42FX250ATS P2A42JX400ATS P2A42LX600ATS P2A42ML125ATS P2A42ML250ATS P2A42ML400ATS P2A42ML600ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P3A56FD250ATS P3A56JD400ATS P3A56LD600ATS P3A56ML250ATS P3A56ML400ATS P3A56ML600ATS P3A56ML800ATS P3A62FD250ATS P3A62JD400ATS P3A62LD600ATS 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 P3C68ML600ATS P3C68ML800ATS P3C74FD250ATS P3C74JD400ATS P3C74LD600ATS P3C74ML250ATS P3C74ML400ATS P3C74ML600ATS P3C74ML800ATS P3C80FD250ATS 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 P3F56ML400ATS P3F56ML600ATS P3F56ML800ATS P3F62FD250ATS P3F62JD400ATS P3F62LD600ATS P3F62ML250ATS P3F62ML400ATS P3F62ML600ATS P3F62ML800ATS 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 P1C42BL100ATS P1C42FX250ATS P1C42FX250ATS P1C42JX400ATS P1C42ML125ATS P1C42ML250ATS P1C42ML400ATS P1C42NB125ATS P1C42QJ225ATS P1E18BD100ATS 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 10-18 P2A42NB125ATS P2A42QJ225ATS P2A54JX400ATS P2A54LX600ATS P2A54ML400ATS P2A54ML600ATS P2BK1 P2BK2 P2BK3 P2C18BL100ATS 10-27 10-27 10-27 10-27 10-27 10-27 PBSB 10-31 PBSB 10-31 PBSB 10-31 10-27 P3A62ML250ATS P3A62ML400ATS P3A62ML600ATS P3A62ML800ATS P3A68FD250ATS P3A68JD400ATS P3A68LD600ATS P3A68ML250ATS P3A68ML400ATS P3A68ML600ATS 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 P3C80JD400ATS P3C80LD600ATS P3C80ML250ATS P3C80ML400ATS P3C80ML600ATS P3C80ML800ATS P3D56FD250ATS P3D56JD400ATS P3D56LD600ATS P3D56ML250ATS 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 P3F68FD250ATS P3F68JD400ATS P3F68LD600ATS P3F68ML250ATS P3F68ML400ATS P3F68ML600ATS P3F68ML800ATS P3F74FD250ATS P3F74JD400ATS P3F74LD600ATS 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 P1E18FX225ATS P1E18FX250ATS P1E18JX400ATS P1E18MC250A P1E18MC250C P1E18MC400A P1E18MC400C P1E18ML125ATS P1E18ML250ATS P1E18ML400ATS 10-18 10-18 10-18 10-10 10-10 10-10 10-10 10-18 10-18 10-18 P2C18FX250ATS P2C18JX400ATS P2C18LX600ATS P2C18ML125ATS P2C18ML250ATS P2C18ML400ATS P2C18ML600ATS P2C18NB125ATS P2C18QJ225ATS P2C30BL100ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P3A68ML800ATS P3A74FD250ATS P3A74JD400ATS P3A74LD600ATS P3A74ML250ATS P3A74ML400ATS P3A74ML600ATS P3A74ML800ATS P3A80FD250ATS P3A80JD400ATS 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 P3D56ML400ATS P3D56ML600ATS P3D56ML800ATS P3D62FD250ATS P3D62JD400ATS P3D62LD600ATS P3D62ML250ATS P3D62ML400ATS P3D62ML600ATS P3D62ML800ATS 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-37 P3F74ML250ATS P3F74ML400ATS P3F74ML600ATS P3F74ML800ATS P3F80FD250ATS P3F80JD400ATS P3F80LD600ATS P3F80ML250ATS P3F80ML400ATS P3F80ML600ATS 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 10-37 10-18 10-18 10-18 10-18 10-18 10-10 10-10 10-10 10-10 10-18 P2C30FX250ATS P2C30JX400ATS P2C30LX600ATS P2C30ML125ATS P2C30ML250ATS P2C30ML400ATS P2C30ML600ATS P2C30NB125ATS P2C30QJ225ATS P2C42BL100ATS 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 10-27 P3A80LD600ATS P3A80ML250ATS P3A80ML400ATS P3A80ML600ATS P3A80ML800ATS P3B56FD250ATS P3B56JD400ATS P3B56LD600ATS P3B56ML250ATS P3B56ML400ATS 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 10-37 10-37 P3D68FD250ATS P3D68JD400ATS P3D68LD600ATS P3D68ML250ATS P3D68ML400ATS P3D68ML600ATS P3D68ML800ATS P3D74FD250ATS P3D74JD400ATS P3D74LD600ATS 10-38 10-38 10-38 10-37 10-37 10-37 10-37 10-38 10-38 10-38 P3F80ML800ATS P4A60JX400ATS P4A60LX600ATS P4A60M1800ATS P4A60ML101ATS P4A60ML120ATS P4A60ML400ATS P4A60ML600ATS P4A60ML800ATS P4A60MS100ATS 10-37 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-48 P1A18QJ225ATS P1A30BL100ATS P1A30FX250ATS P1A30JX400ATS P1A30MC250A P1A30MC250C P1A30MC400A P1A30MC400C P1A30ML125ATS P1A30ML250ATS P1A30ML400ATS P1A30NB125ATS P1A30QJ225ATS P1A42BL100ATS P1A42FX250ATS P1A42JX400ATS P1A42MC250A P1A42MC250C P1A42MC400A P1A42MC400C P1E18NB125ATS P1E30BD100ATS P1E30FX225ATS P1E30FX250ATS P1E30JX400ATS P1E30MC250A P1E30MC250C P1E30MC400A P1E30MC400C P1E30ML125ATS UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-13 PRODUCT INDEX P1E30ML250ATS P1E30ML400ATS P1E30NB125ATS P1E42BD100ATS P1E42FX225ATS P1E42FX250ATS P1E42JX400ATS P1E42MC250A P1E42MC250C P1E42MC400A 19 1-40 1-40 1-40 1-40 1-40 1-40 1-40 1-40 1-40 10-18 P1A18FX250ATS P1A18JX400ATS P1A18MC250A P1A18MC250C P1A18MC400A P1A18MC400C P1A18ML125ATS P1A18ML250ATS P1A18ML400ATS P1A18NB125ATS RESG RESG RESG RESG RESG RESG RESG RESG RESG Page Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page P4A60MS200ATS P4A75JX400ATS P4A75LX600ATS P4A75M1800ATS P4A75ML101ATS P4A75ML120ATS P4A75ML400ATS P4A75ML600ATS P4A75ML800ATS P4A75MS100ATS 10-48 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-48 P4D75ML400ATS P4D75ML600ATS P4D75ML800ATS P4D75MS100ATS P4D75MS200ATS P4D90JX400ATS P4D90LX600ATS P4D90M1800ATS P4D90ML101ATS P4D90ML120ATS 10-47 10-47 10-47 10-48 10-48 10-47 10-47 10-47 10-47 10-47 P5A90MS400ATS P5A90MS600ATS P5A90MS800ATS P5A90N1120ATS P5B60M1800ATS P5B60ML101ATS P5B60ML120ATS P5B60ML800ATS P5B60N1120ATS P5B75M1800ATS 10-58 10-58 10-58 10-57 10-57 10-57 10-57 10-57 10-57 10-57 P5E90ML800ATS P5E90MS120ATS P5E90MS400ATS P5E90MS600ATS P5E90MS800ATS P5E90N1120ATS P5F60M1800ATS P5F60ML101ATS P5F60ML120ATS P5F60ML800ATS 10-57 10-58 10-58 10-58 10-58 10-57 10-57 10-57 10-57 10-57 PCBLFC3 PCBLRC3 PCBMRC3 PCBNRC3 PCCJD PCCJD PCCLD PCCLD PCTF83 PCTF83 P4A75MS200ATS P4A90JX400ATS P4A90LX600ATS P4A90M1800ATS P4A90ML101ATS P4A90ML120ATS P4A90ML400ATS P4A90ML600ATS P4A90ML800ATS P4B60JX400ATS 10-48 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 P4D90ML400ATS P4D90ML600ATS P4D90ML800ATS P4E60JX400ATS P4E60LX600ATS P4E60M1800ATS P4E60ML101ATS P4E60ML120ATS P4E60ML400ATS P4E60ML600ATS 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 P5B75ML101ATS P5B75ML120ATS P5B75ML800ATS P5B75MS120ATS P5B75MS400ATS P5B75MS600ATS P5B75MS800ATS P5B75N1120ATS P5B90M1800ATS P5B90ML101ATS 10-57 10-57 10-57 10-58 10-58 10-58 10-58 10-57 10-57 10-57 P5F60N1120ATS P5F75M1800ATS P5F75ML101ATS P5F75ML120ATS P5F75ML800ATS P5F75MS120ATS P5F75MS400ATS P5F75MS600ATS P5F75MS800ATS P5F75N1120ATS 10-57 10-57 10-57 10-57 10-57 10-58 10-58 10-58 10-58 10-57 PCTL83 PCTL83 PCTM83 PCTP83 PCTP83 PCXD3 PCXF3 PCXFT PCXFT PCXJ3 P4B60LX600ATS P4B60M1800ATS P4B60ML101ATS P4B60ML120ATS P4B60ML400ATS P4B60ML600ATS P4B60ML800ATS P4B60MS100ATS P4B60MS200ATS P4B75JX400ATS 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-48 10-48 10-47 P4E60ML800ATS P4E60MS100ATS P4E60MS200ATS P4E75JX400ATS P4E75LX600ATS P4E75M1800ATS P4E75ML101ATS P4E75ML120ATS P4E75ML400ATS P4E75ML600ATS 10-47 10-48 10-48 10-47 10-47 10-47 10-47 10-47 10-47 10-47 P5B90ML120ATS P5B90ML800ATS P5B90MS120ATS P5B90MS400ATS P5B90MS600ATS P5B90MS800ATS P5B90N1120ATS P5C60M1800ATS P5C60ML101ATS P5C60ML120ATS 10-57 10-57 10-58 10-58 10-58 10-58 10-57 10-57 10-57 10-57 P5F77RBS P5F7TS P5F90M1800ATS P5F90ML101ATS P5F90ML120ATS P5F90ML800ATS P5F90MS120ATS P5F90MS400ATS P5F90MS600ATS P5F90MS800ATS 1-40 1-40 10-57 10-57 10-57 10-57 10-58 10-58 10-58 10-58 PCXL3 PCXLT PCXLT PCXM3 PCXMT PCXN3 PCXPT PCXPT PD63B120 PD63B140 6-131 6-131 6-131 6-131 6-131 6-131 6-131 6-131 MCCB 6-59 MCCB 6-59 P4B75LX600ATS P4B75M1800ATS P4B75ML101ATS P4B75ML120ATS P4B75ML400ATS P4B75ML600ATS P4B75ML800ATS P4B75MS100ATS P4B75MS200ATS P4B90JX400ATS 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-48 10-48 10-47 P4E75ML800ATS P4E75MS100ATS P4E75MS200ATS P4E90JX400ATS P4E90LX600ATS P4E90M1800ATS P4E90ML101ATS P4E90ML120ATS P4E90ML400ATS P4E90ML600ATS 10-47 10-48 10-48 10-47 10-47 10-47 10-47 10-47 10-47 10-47 P5C60ML800ATS P5C60N1120ATS P5C75M1800ATS P5C75ML101ATS P5C75ML120ATS P5C75ML800ATS P5C75MS120ATS P5C75MS400ATS P5C75MS600ATS P5C75MS800ATS 10-57 10-57 10-57 10-57 10-57 10-57 10-58 10-58 10-58 10-58 P5F90N1120ATS P77BS P77RBS P77RTS P77TS P77US PAKMCVRL PAKMCVRR PB224 PB226 10-57 1-40 1-40 1-40 1-40 1-40 2-82 2-82 SWBD 12-20 SWBD 12-20 PD63B160 PD63F160 PD63T120 PD63T120 PD63T140 PD63T140 PD63T160 PD63T160 PE4630 PE4840 MCCB 6-59 MCCB 6-59 MCCB 6-59 MCCB 6-59 MCCB 6-59 MCCB 6-59 MCCB 6-59 MCCB 6-59 SWBD 12-22 SWBD 12-22 P4B90LX600ATS P4B90M1800ATS P4B90ML101ATS P4B90ML120ATS P4B90ML400ATS P4B90ML600ATS P4B90ML800ATS P4C60JX400ATS P4C60LX600ATS P4C60M1800ATS 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 P4E90ML800ATS P4F60JX400ATS P4F60LX600ATS P4F60M1800ATS P4F60ML101ATS P4F60ML120ATS P4F60ML400ATS P4F60ML600ATS P4F60ML800ATS P4F60MS100ATS 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-48 P5C75N1120ATS P5C90M1800ATS P5C90ML101ATS P5C90ML120ATS P5C90ML800ATS P5C90MS120ATS P5C90MS400ATS P5C90MS600ATS P5C90MS800ATS P5C90N1120ATS 10-57 10-57 10-57 10-57 10-57 10-58 10-58 10-58 10-58 10-57 PB228 PB424 PB426 PB428 PB444 PB446 PB448 PBP32 PC2637 PC2637 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD MCCB MCCB 12-20 12-20 12-20 12-20 12-20 12-20 12-20 12-23 6-91 6-91 PEGB42 PF224 PF226 PF424 PF426 PF444 PF446 PF4606 PF4809 PLK400 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD RESG 12-23 12-21 12-21 12-21 12-21 12-21 12-21 12-22 12-22 2-74 P4C60ML101ATS P4C60ML120ATS P4C60ML400ATS P4C60ML600ATS P4C60ML800ATS P4C60MS100ATS P4C60MS200ATS P4C75JX400ATS P4C75LX600ATS P4C75M1800ATS 10-47 10-47 10-47 10-47 10-47 10-48 10-48 10-47 10-47 10-47 P4F60MS200ATS P4F75JX400ATS P4F75LX600ATS P4F75M1800ATS P4F75ML101ATS P4F75ML120ATS P4F75ML400ATS P4F75ML600ATS P4F75ML800ATS P4F75MS100ATS 10-48 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-48 P5D60M1800ATS P5D60ML101ATS P5D60ML120ATS P5D60ML800ATS P5D60N1120ATS P5D75M1800ATS P5D75ML101ATS P5D75ML120ATS P5D75ML800ATS P5D75MS120ATS 10-57 10-57 10-57 10-57 10-57 10-57 10-57 10-57 10-57 10-58 PC2638 PC2638 PC2657 PC2657 PC2658 PC2658 PC4753 PC4753 PC4753 PC4753 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 PLK400 PLK600 PLK600 PLL44 PLL46 PLL48 PLW10 PMS13 PMS15 PMS5 RESG RESG RESG SWBD SWBD SWBD SWBD SWBD SWBD SWBD 2-81 2-74 2-81 12-23 12-23 12-23 12-23 12-23 12-23 12-23 P4C75ML101ATS P4C75ML120ATS P4C75ML400ATS P4C75ML600ATS P4C75ML800ATS P4C75MS100ATS P4C75MS200ATS P4C90JX400ATS P4C90LX600ATS P4C90M1800ATS 10-47 10-47 10-47 10-47 10-47 10-48 10-48 10-47 10-47 10-47 P4F75MS200ATS P4F90JX400ATS P4F90LX600ATS P4F90M1800ATS P4F90ML101ATS P4F90ML120ATS P4F90ML400ATS P4F90ML600ATS P4F90ML800ATS P577TS 10-48 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 RESG 1-40 P5D75MS400ATS P5D75MS600ATS P5D75MS800ATS P5D75N1120ATS P5D90M1800ATS P5D90ML101ATS P5D90ML120ATS P5D90ML800ATS P5D90MS120ATS P5D90MS400ATS 10-58 10-58 10-58 10-57 10-57 10-57 10-57 10-57 10-58 10-58 PC4754 PC4754 PC4754 PC4754 PC5660 PC5660 PC5661 PC5661 PC5662 PC5662 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 PMS6 PMS8 PQ2630 PQ2840 PQ4630 PQ4840 PRD6N1 PRD6N1 PSDP32 PSFFJ6 SWBD SWBD SWBD SWBD SWBD SWBD 12-23 12-23 12-22 12-22 12-22 12-22 5-8 6-60 SWBD 12-23 SWBD 12-22 P4C90ML101ATS P4C90ML120ATS P4C90ML400ATS P4C90ML600ATS P4C90ML800ATS P4D60JX400ATS P4D60LX600ATS P4D60M1800ATS P4D60ML101ATS P4D60ML120ATS 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 10-47 P577US P5A60M1800ATS P5A60ML101ATS P5A60ML120ATS P5A60ML800ATS P5A60N1120ATS P5A75M1800ATS P5A75ML101ATS P5A75ML120ATS P5A75ML800ATS RESG 1-40 10-57 10-57 10-57 10-57 10-57 10-57 10-57 10-57 10-57 P5D90MS600ATS P5D90MS800ATS P5D90N1120ATS P5E60M1800ATS P5E60ML101ATS P5E60ML120ATS P5E60ML800ATS P5E60N1120ATS P5E75M1800ATS P5E75ML101ATS 10-58 10-58 10-57 10-57 10-57 10-57 10-57 10-57 10-57 10-57 PC5663 PC5663 PC5664 PC5664 PC5666 PC5666 PC5777 PC5777 PC5778 PC5778 MCCB MCCB 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 PSFJL6 PSP32 PTE PUG14 PUG26 PXD63B120 PXD63B140 PXD63B160 PXD63S160A Q110 SWBD 12-22 SWBD 12-23 12-24 SWBD 12-23 SWBD 12-23 MCCB 6-59 MCCB 6-59 MCCB 6-59 MCCB 6-72 RESI 1-24 P4D60ML400ATS P4D60ML600ATS P4D60ML800ATS P4D60MS100ATS P4D60MS200ATS P4D75JX400ATS P4D75LX600ATS P4D75M1800ATS P4D75ML101ATS P4D75ML120ATS 10-47 10-47 10-47 10-48 10-48 10-47 10-47 10-47 10-47 10-47 P5A75MS120ATS P5A75MS400ATS P5A75MS600ATS P5A75MS800ATS P5A75N1120ATS P5A90M1800ATS P5A90ML101ATS P5A90ML120ATS P5A90ML800ATS P5A90MS120ATS 10-58 10-58 10-58 10-58 10-57 10-57 10-57 10-57 10-57 10-58 P5E75ML120ATS P5E75ML800ATS P5E75MS120ATS P5E75MS400ATS P5E75MS600ATS P5E75MS800ATS P5E75N1120ATS P5E90M1800ATS P5E90ML101ATS P5E90ML120ATS 10-57 10-57 10-58 10-58 10-58 10-58 10-57 10-57 10-57 10-57 PCAF390 PCAF390 PCBDFC3 PCBDRC3 PCBERC3 PCBERC4 PCBFFC3 PCBFRC3 PCBJFC3 PCBJRC3 19-14 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog RESG RESG RESG RESG RESG RESG RESG MCCB MCCB MCCB MCCB MCCB MCCB 6-130 6-130 6-130 6-130 6-91 6-91 6-130 6-130 6-131 6-131 Q115 Q115AF Q115AFH Q115H Q115HH Q115HID Q115T Q120 Q120AF Q120AFH 6-131 6-131 6-131 6-131 MCCB 6-91 MCCB 6-91 6-91 6-91 6-130 6-130 6-131 6-131 6-131 6-131 6-131 6-130 6-130 6-130 6-130 6-131 RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-24 1-26 1-26 1-24 1-24 1-27 1-27 1-24 1-26 1-26 Product Index Catalog Number Product Category Q120H Q120HH Q120HID Q120T Q125 Q125H Q125HH Q130 Q130H Q130HH RESI RESI RESI Page Catalog Number Product Category Page RESI RESI RESI RESI RESI RESI 1-24 1-24 1-27 1-27 1-24 1-24 1-24 1-24 1-24 1-24 Q2225B Q2225BH Q2225BHH Q225 Q225H Q225HH Q230 Q23020CT2 Q23030CT Q23030CT2 RESI RESI RESI RESI RESI RESI RESI RESI Q130HID Q135 Q135H Q135HH Q140 Q140H Q140HH Q145 Q145H Q145HH RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-27 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 Q150 Q150H Q150HH Q1515 Q1515NC Q1520 Q1520NC Q160 Q160H Q160HH RESI RESI Catalog Number Product Category Page Q23050CT2 Q230H Q230HH Q230HID Q230R Q230S Q235 Q235H Q235HH Q240 RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-25 1-24 1-24 1-27 1-24 1-27 1-24 1-24 1-24 1-24 QE130 QE130H QE215 QE215H QE220 QE220H QE230 QE230H QE240 QE240H RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-24 1-24 1-24 1-25 1-25 1-25 1-25 1-24 1-24 1-24 Q24020CT2 Q24030CT2 Q24040CT2 Q240H Q240HH Q240R Q245 Q245H Q245HH Q250 RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-25 1-25 1-25 1-24 1-24 1-24 1-24 1-24 1-24 1-24 Q170 Q170H Q170HH Q2020 Q2020NC Q2030 Q210 Q2100 Q2100H Q2100HH RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-24 1-24 1-24 1-25 1-25 1-25 1-24 1-24 1-24 1-24 Q250H Q250HH Q250NN Q250R Q260 Q260H Q260HH Q260NN Q260R Q260S RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI Q2100R Q2110 Q2110H Q2110HH Q2125 Q2125B Q2125BH Q2125BHH Q2125H Q2125HH RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-24 1-24 1-24 1-24 1-24 1-29 1-29 1-29 1-24 1-24 Q270 Q270H Q270HH Q270NN Q270R Q280 Q280H Q280HH Q290 Q290H RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI Q215 Q2150B Q2150BH Q2150BHH Q21515CT Q21515CT2 Q21520CT Q21525CT Q21530CT Q21535CT RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-24 1-29 1-29 1-29 1-25 1-25 1-25 1-25 1-25 1-25 Q290HH Q290NN Q3015 Q3020 Q3030 Q3030NC Q310 Q3100 Q3100H Q3100HH Q21540CT Q21545CT Q21550CT Q215AF Q215AFH Q215H Q215HH Q215HID Q215R Q2175B RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-25 1-25 1-25 1-26 1-26 1-24 1-24 1-27 1-24 1-29 Q315 Q315H Q315HH Q320 Q320H Q320HH Q325 Q325H Q325HH Q330 RESI RESI RESI RESI RESI RESI RESI RESI Q2175BH Q2175BHH Q220 Q2200B Q2200BH Q2200BHH Q22020CT Q22020CT2 Q22025CT Q22030CT RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-29 1-29 1-24 1-29 1-29 1-29 1-25 1-25 1-25 1-25 Q330H Q330HH Q335 Q335H Q335HH Q340 Q340H Q340HH Q345 Q345H RESI RESI RESI Q22035CT Q22040CT Q22045CT Q22050CT Q220AF Q220AFH Q220H Q220HH Q220HID Q220R RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-25 1-25 1-25 1-25 1-26 1-26 1-24 1-24 1-27 1-24 Q345HH Q350 Q350H Q350HH Q360 Q360H Q360HH Q370 Q370H Q370HH Product Category Page 1-24 1-24 1-24 1-24 1-24 1-24 1-26 1-26 1-26 1-26 QJ23B110H QJ23B125 QJ23B125H QJ23B150 QJ23B150H QJ23B175 QJ23B175H QJ23B200 QJ23B200H QJ23B225 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 RCW(1)50B RCW(1)53B RCW(1)56B RCW(1)59B RCW(1)62B RCW(1)65B RCW(1)68B RCW(1)71B RCW(1)74B RCW(1)77B RESI RESI 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 QJ23B225H QJ23S225A QJH22B060 QJH22B070 QJH22B080 QJH22B090 QJH22B100 QJH22B110 QJH22B125 QJH22B150 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-28 6-72 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 RD63B160 RD63B180 RD63B200 RD63F200 RD63T160 RD63T160 RD63T180 RD63T180 RD63T200 RD63T200 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-62 6-62 6-62 6-62 6-62 6-62 6-62 6-62 6-62 6-62 QE250 QE250H QE260 QE260H QF115 QF115H QF120 QF120H QF125 QF130 RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 QJH22B175 QJH22B200 QJH22B225 QJH23B060 QJH23B070 QJH23B080 QJH23B090 QJH23B100 QJH23B110 QJH23B125 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 REC3100G REC4100G RFC3250G RFC4250G RHFESD RHFESDEM RHFF RHFFEM RHFL RHFLEM BPLU BPLU BPLU BPLU MCCB MCCB 14-57 14-57 14-57 14-57 6-88 6-88 6-126 6-126 6-126 6-126 1-24 1-24 1-27 1-24 1-24 1-24 1-24 1-27 1-24 1-27 QF130H QF215 QF215H QF220 QF220H QF230 QF230H QF240 QF240H QF250 RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 1-26 QJH23B150 QJH23B175 QJH23B200 QJH23B225 QJHS1 QJHS1 QL1 QLD3 QN2150 QN2150H MCCB 6-28 MCCB 6-28 MCCB 6-28 MCCB 6-28 MCCB 12-23 MCCB 6-86 12-23 12-23 RESI 1-29 RESI 1-29 1-24 1-24 1-24 1-27 1-24 1-24 1-24 1-24 1-24 1-24 QF250H QF260 QF260H QF3 QF3 QF3 QF3 QF3 QF3 QF3 RESI RESI RESI RESG RESG RESG RESG RESG RESG RESG 1-26 1-26 1-26 10-11 10-50 10-61 12-23 12-26 1-35 6-86 QN2150R QN2150RH QN2175 QN2175H QN2175R QN2175RH QN2200 QN2200H QN2200R QN2200RH RESI RESI RESI 1-24 1-27 1-25 1-25 1-25 1-25 1-24 1-24 1-24 1-24 QG215 QG220 QG230 QG315 QG320 QG330 QJ22B060 QJ22B060H QJ22B070 QJ22B070H RESI RESI RESI RESI RESI MCCB MCCB MCCB MCCB 1-27 1-27 1-27 1-27 1-27 1-27 6-28 6-28 6-28 6-28 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 QJ22B080 QJ22B080H QJ22B090 QJ22B090H QJ22B100 QJ22B100H QJ22B110 QJ22B110H QJ22B125 QJ22B125H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB RESI RESI RESI RESI RESI 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 QJ22B150 QJ22B150H QJ22B175 QJ22B175H QJ22B200 QJ22B200H QJ22B225 QJ22B225H QJ22S225A QJ23B060 RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 1-24 QJ23B060H QJ23B070 QJ23B070H QJ23B080 QJ23B080H QJ23B090 QJ23B090H QJ23B100 QJ23B100H QJ23B110 RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI Catalog Number RESI RESI RESI RESI RESI RESI 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 RHFM RHFMEM RHOCQVD RHOEBO RHOFBO RHOH RHOH RHOH4 RHOH4 RHOH62 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-127 6-127 6-88 6-88 6-88 4-12 6-88 4-12 6-88 6-88 RESI RESI RESI RESI RESI RESI 1-29 1-29 1-29 1-29 1-29 1-29 1-29 1-29 1-29 1-29 RHOJBO RHOLMBO RHONBO RHONSD RHONSSD RHONSVD RHONSXD RHOS06 RHOS06 RHOS06 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-88 6-88 6-88 6-88 6-88 6-88 6-88 4-12 4-12 4-12 QPJ3125 QPJ3150 QPJ3200 QSA1515 QSA2020 QSA2020TVSS QW215 QW220 QW230 R1224ML1125CU RESI RESI RESI RESI RESI RESI RESI RESI RESI RESI 1-29 1-29 1-29 1-32 1-32 1-32 1-27 1-27 1-27 1-14 RHOS20 RHOSSD RHOSVD RHOSVD RHOSVD RHOSVD RHOSVD RHOSXD RHSFA1 RHSFA1F MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 4-12 6-88 4-12 4-12 4-12 4-12 6-88 6-88 6-126 6-126 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 R2040ML1125CU RAG24 RC(1)23B RC(1)26B RC(1)29B RC(1)32B RC(1)35B RC(1)38B RC(1)41B RC(1)44B RESI RESI 1-14 1-35 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 RHSFA2 RHSFA2F RHSLA1 RHSLA1F RHSLA2 RHSLA2F RHSMA1 RHSMA1F RHSMA2 RHSMA2F MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-72 6-28 RC(1)47B RC(1)50B RC(1)53B RC(1)56B RC(1)59B RC(1)62B RC(1)65B RC(1)68B RC(1)71B RC(1)74B 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 RHSPA1 RHSPA1F RHSPA2 RHSPA2F RHVE64X RHVF12 RHVFBM RHVL12 RHVLBM RHVM12 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 6-28 RC(1)77B RCW(1)23B RCW(1)26B RCW(1)29B RCW(1)32B RCW(1)35B RCW(1)38B RCW(1)41B RCW(1)44B RCW(1)47B 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 10-71 RHVM12H RHVM12H RHVM12H RHVM3RH RHVM3RH RHVM3RH RHVM4XH RHVM4XH RHVM4XH RHVMBM Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 6-126 6-126 6-126 6-126 6-126 6-126 6-127 6-127 6-127 6-127 6-127 6-127 6-127 6-127 MCCB 6-88 6-126 6-126 6-126 6-126 6-127 6-126 6-126 6-127 6-126 6-126 6-127 6-126 6-126 6-127 6-127 19-15 PRODUCT INDEX Q380 Q380H Q380HH Q390 Q390H Q390HH QE115 QE115H QE120 QE120H Product Category Page 19 RESI 1-29 1-29 1-29 1-24 1-24 1-24 1-24 1-25 1-25 1-25 Catalog Number Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number RHVMEMH RHVMEMH RHVMEMH RHVMS02 RHVMS02 RHVMS02 RHVMS12 RHVMS12 RHVMS12 RHVMS16 6-126 6-126 6-127 6-126 6-126 6-127 6-126 6-126 6-127 6-126 RV365SG RV366G RV421G RV422G RV423G RV424G RV425G RV426G RV461G RV462G RHVMS16 RHVMS16 RHVP3RH RHVP3RH RHVP4XH RHVPBM RHVPEMH RHVPS03 RHVPS12 RHVPS24 6-126 6-127 6-127 6-127 6-127 6-127 6-127 6-127 6-127 6-127 Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 S09JLD6 S09JLD6 S09JLD62A S09JLD62A S09JLD62A S09MN6 S09MN6 S09MN6 S09MN6 S11FD60 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-47 6-50 6-43 6-47 6-50 6-54 6-58 6-61 6-63 6-39 S38B S40007-01GP S40404-02QG S40405-015F S40405-025 S40405-02CO S40405-02QG S40405-0BNU S40407-015F S40407-01NU UNPB 10-10 RESG 2-7 2-7 RESG 2-7 RESG 2-7 RESG 2-7 RESG 2-7 RESG 2-7 RESG 2-7 RESG 2-7 SCJD69200 SCJD69200G SCJD69200NGT SCJD69200NT SCJD69300 SCJD69300G SCJD69300NGT SCJD69300NT SCJD69400 SCJD69400G MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB RV463G RV464G RV465G RV465SG RV466G RXD63B160 RXD63B180 RXD63B200 RXD63S200A S01ED62A BPLU BPLU BPLU BPLU BPLU MCCB MCCB MCCB MCCB MCCB 14-57 14-57 14-57 14-57 14-57 6-62 6-62 6-62 6-72 6-36 S11JLD6 S11JLD6 S11JLD6 S11JLD62A S11JLD62A S11JLD62A S11MN6 S11MN6 S11MN6 S11MN6 MCCB MCCB MCCB MCCB MCCB MCCB 6-43 6-47 6-50 6-43 6-47 6-50 6-54 6-58 6-61 6-63 S40407-025 S40407-02CO S40407-02QG S42505-02RG S44305-02CV S44307-02CV S44704-8265 S44B S44B S44B RESG RESG RESG RESG RESG UNPB UNPB UNPB 2-7 2-7 2-7 2-7 2-7 2-7 2-8 10-10 10-10 10-10 SCJD69400NGT SCJD69400NT SCL SCLD SCLD69300 SCLD69300G SCLD69300NGT SCLD69300NT SCLD69400 SCLD69400G MCCB 6-42 MCCB 6-42 PBSB 10-50 10-61 MCCB 6-46 MCCB 6-46 MCCB 6-46 MCCB 6-46 MCCB 6-46 MCCB 6-46 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 RHVPS24 RJC3400G RJC4400G RLC3600G RLC4600G RMC3800G RMC4800G RS2641 RS2642 RS2643 BPLU BPLU BPLU BPLU BPLU BPLU MCCB MCCB MCCB 6-127 14-57 14-57 14-57 14-57 14-57 14-57 6-91 6-91 6-91 S01ED62AA S01ED62AB S01ED62B S01FD60 S01JLD6 S01JLD6 S01JLD6 S01JLD62A S01JLD62A S01JLD62A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-36 6-36 6-36 6-39 6-43 6-47 6-50 6-43 6-47 6-50 S11MN64A S11MN64A S11MN64A S11MN64A S13FD60 S13JLD6 S13JLD6 S13JLD6 S13JLD62A S13JLD62A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-39 6-43 6-47 6-50 6-43 6-47 S44B S44B S44B S47604-81GP S47605-02SP S47704-01NU S47704-02 S47705-01NU S47707-01NU S47707-02 UNPB 10-10 UNPB 10-10 UNPB 10-10 RESG 2-8 RESG 2-8 RESG 2-8 RESG 2-8 RESG 2-8 RESG 2-8 RESG 2-8 SCLD69400NGT SCLD69400NT SCLD69500 SCLD69500G SCLD69500NGT SCLD69500NT SCLD69600 SCLD69600G SCLD69600NGT SCLD69600NT MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 RS2644 RS4755 RS4755 RS4756 RS4756 RS5773 RS5773 RS5774 RS5774 RS5783 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 S01MN6 S01MN6 S01MN6 S01MN6 S01MN64A S01MN64A S01MN64A S02MN6 S02MN6 S02MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-54 6-61 6-63 6-54 6-58 6-61 S13JLD62A S13MN6 S13MN6 S13MN6 S13MN6 S13MN6 S13MN6 S13MN64A S13MN64A S13MN64A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-50 6-54 6-54 6-58 6-58 6-61 6-63 6-58 6-61 6-63 S48104-02 S48105-83BU S48504-92 S48704-82GP S48707-82GP S48805-0BNU S48807-02NU S56B S56B S56B RESG 2-8 RESG 2-8 RESG 2-8 RESG 2-8 RESG 2-8 RESG 2-7 RESG 2-7 UNPB 10-10 UNPB 10-10 UNPB 10-10 SCMD69600A SCMD69600AG SCMD69600AGH SCMD69600AH SCMD69600ANGT SCMD69600ANGTH SCMD69600ANT SCMD69600ANTH SCMD69700A SCMD69700AG MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 RS5783 RS5784 RS5784 RS5785 RS5785 RS5786 RS5786 RS5787 RS5787 RS5788 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-91 S02MN6 S03FD60 S03JLD6 S03JLD6 S03JLD6 S03JLD62A S03JLD62A S03JLD62A S03MN6 S03MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-63 6-39 6-43 6-47 6-50 6-43 6-47 6-50 6-54 6-58 S15FD60 S15JLD6 S15JLD6 S15JLD6 S15JLD64A S15JLD64A S15JLD64A S15MN6 S15MN6 S15MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-39 6-43 6-47 6-50 6-43 6-47 6-50 6-54 6-58 6-61 S56B S56B S62B S62B S62B S62B S62B S62B S68B S68B UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 SCMD69700AGH SCMD69700AH SCMD69700ANGT SCMD69700ANGTH SCMD69700ANT SCMD69700ANTH SCMD69800A SCMD69800AG SCMD69800AGH SCMD69800AH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 RS5788 RT121413 RT6019A RT6019HA RT6067A RT6067HA RTLDLF RTLDLR RTLDSF RTLDSR MCCB RESG 6-91 2-9 2-9 2-9 2-9 2-9 6-132 6-132 6-132 6-132 S03MN6 S03MN6 S03MN64A S03MN64A S03MN64A S03MN64A S04FD60 S04JLD6 S04JLD6 S04JLD6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-43 6-47 6-50 S15MN6 S15MN64A S15MN64A S15MN64A S15MN64A S16FD60 S16JLD6 S16JLD6 S16JLD6 S16JLD62A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-63 6-54 6-58 6-61 6-63 6-39 6-43 6-47 6-50 6-43 S68B S68B S68B S68B S69623 S69685-1 S9804-9142 S9804-9144 S9804-9145 S9804-9146 UNPB UNPB UNPB UNPB RESG RESG RESG RESG RESG 10-10 10-10 10-10 10-10 2-10 2-10 2-7 2-8 2-8 2-8 SCMD69800ANGT SCMD69800ANGTH SCMD69800ANT SCMD69800ANTH SCND69100A SCND69100AG SCND69100AGH SCND69100AH SCND69100ANGT SCND69100ANGTH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-53 6-53 6-53 6-57 6-57 6-57 6-57 6-57 6-57 RTLELR RTLELR RTLESR RTLESR RTLFLF RTLFLR RTLFSF RTLFSR RTLJLF RTLJLR MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-91 6-91 6-91 6-91 6-132 6-132 6-132 6-132 6-133 6-133 S04MN6 S04MN6 S04MN6 S04MN6 S04MN64A S04MN64A S04MN64A S04MN64A S06FD60 S06MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-54 S16JLD62A S16JLD62A S16MN6 S16MN6 S16MN6 S16MN6 S16MN64A S16MN64A S16MN64A S16MN64A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-47 6-50 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 S9804-9147 S9817-8061 SA1E025 SADU SADU SADU SADU SADU SADU SADU RESG RESG MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 2-8 2-8 6-82 6-43 6-47 6-50 6-54 6-58 6-61 6-63 SCND69100ANT SCND69100ANTH SCND69120A SCND69120AG SCND69120AGH SCND69120AH SCND69120ANGT SCND69120ANGTH SCND69120ANT SCND69120ANTH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 RTLJSF RTLJSR RTLLSF RTLMSF RTLNSF RTU121814 RTU121815 RTU121818 RTU122015 RV321G MCCB 6-133 MCCB 6-133 6-133 6-133 6-133 2-9 2-9 2-9 2-9 BPLU 14-57 S06MN6 S06MN6 S06MN6 S07FD60 S07JLD6 S07JLD6 S07JLD6 S07JLD62A S07JLD62A S07JLD62A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-58 6-61 6-63 6-39 6-43 6-47 6-50 6-43 6-47 6-50 S17ED60 S17FD60 S17JLD6 S17JLD6 S17JLD6 S18JLD6 S18JLD6 S18JLD6 S32B S32B MCCB 6-36 MCCB 6-39 MCCB 6-43 MCCB 6-47 MCCB 6-50 MCCB 6-43 MCCB 6-47 MCCB 6-50 UNPB 10-10 UNPB 10-10 SADU SADURMK18 SADURMK18 SADURMK18 SADURMK18 SADURMK18 SADURMK18 SADURMK18 SADURMK18 SBJ1 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB RESG 6-79 6-43 6-47 6-50 6-54 6-58 6-61 6-63 6-79 2-81 SCND69800A SCND69800AG SCND69800AGH SCND69800AH SCND69800ANGT SCND69800ANGTH SCND69800ANT SCND69800ANTH SCT1236 SCT432 MCCB 6-57 MCCB 6-57 MCCB 6-57 MCCB 6-57 MCCB 6-57 MCCB 6-57 MCCB 6-57 MCCB 6-57 SWBD 12-25 SWBD 12-25 MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-43 S32B S32B S32B S32B S35815-2 S38B S38B S38B S38B S38B UNPB UNPB UNPB UNPB RESG UNPB UNPB UNPB UNPB UNPB SBJ4 SBL SBLBD SBLBD SCE SCED SCF SCFD SCJ SCJD RESG PBSB PBSB PBSB PBSB PBSB PBSB SCT436 SCT632 SCT636 SCT836 SE6 SE6D SE6D SEAER SEAFB SEAFM SWBD SWBD SWBD SWBD PBSB PBSB PBSB RV322G RV323G RV324G RV325G RV326G RV361G RV362G RV363G RV364G RV365G 19-16 BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 14-57 S07MN6 S07MN6 S07MN6 S07MN6 S07MN64A S07MN64A S07MN64A S07MN64A S09FD60 S09JLD6 10-10 10-10 10-10 10-10 2-10 10-10 10-10 10-10 10-10 10-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 2-81 10-50 10-61 12-26 10-50 10-61 10-50 10-61 PBSB 10-50 10-61 12-25 12-25 12-25 12-25 10-50 10-61 10-61 6-90 MCCB 6-130 MCCB 6-130 Product Index Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number SEAFN SEAFR SEAFY SEALB SEALM SEALN SEALR SEALY SEAMB SEAMM MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-130 6-130 6-130 6-131 6-131 6-131 6-131 6-131 6-131 6-131 SHND69100AH SHND69100ANGT SHND69100ANGTH SHND69100ANT SHND69100ANTH SHND69120A SHND69120AG SHND69120AGH SHND69120AH SHND69120ANGT MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 SLEC34***0GED4 SLEC34***0GED4 SLEC34***0GED4 SLEC34***0IGED4 SLEC34***0IGED4 SLEC34***0IGED4 SLEC36***0ED6 SLEC36***0ED6 SLEC36***0ED6 SLEC36***0GED6 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLFC36***0FXD6 SLFC36***0GFXD6 SLFC36***0IGFXD6 SLFC362500FXD6 SLFC362500GFXD6 SLFC362500IGFXD6 SLFC46***0FXD6 SLFC46***0GFXD6 SLFC46***0IGFXD6 SLFC462500FXD6 SEAMN SEAMR SEAMY SEB SEBD SF6 SF6D SHHTD63F2000 SHHTD63F2000H SHHTD63F2500 MCCB MCCB MCCB PBSB PBSB 6-131 6-131 6-131 10-50 12-26 10-50 10-61 6-64 6-64 6-64 SHND69120ANGTH SHND69120ANT SHND69120ANTH SHND69800A SHND69800AG SHND69800AGH SHND69800AH SHND69800ANGT SHND69800ANGTH SHND69800ANT MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 SLEC36***0GED6 SLEC36***0GED6 SLEC36***0IGED6 SLEC36***0IGED6 SLEC36***0IGED6 SLEC42***0ED2 SLEC42***0ED2 SLEC42***0GED2 SLEC42***0GED2 SLEC42***0IGED2 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLFC462500GFXD6 SLFC462500IGFXD6 SLFC56***0FXD6 SLFC56***0FXD6 SLFC56***0GFXD6 SLFC56***0GFXD6 SLFC56***0IGFXD6 SLFC56***0IGFXD6 SLFL36***0CFD6 SLFL36***0GCFD6 SHND69800ANTH SHPD69140 SHPD69140G SHPD69140NGT SHPD69140NT SHPD69160 SHPD69160G SHPD69160NGT SHPD69160NT SHTD63F2000 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-57 6-60 6-60 6-60 6-60 6-60 6-60 6-60 6-60 6-64 SLEC42***0IGED2 SLEC44***0ED4 SLEC44***0ED4 SLEC44***0ED4 SLEC44***0GED4 SLEC44***0GED4 SLEC44***0GED4 SLEC44***0IGED4 SLEC44***0IGED4 SLEC44***0IGED4 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLEC46***0ED6 SLEC46***0ED6 SLEC46***0ED6 SLEC46***0GED6 SLEC46***0GED6 SLEC46***0GED6 SLEC46***0IGED6 SLEC46***0IGED6 SLEC46***0IGED6 SLEC52***0ED2 Product Category Page 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 Catalog Number Product Category Page SLR6060 SLR6100 SLR6200 SLR6400 SLR6600 SLT2100 SLT2200 SLT2400 SLT2600 SLT6100 BPLU BPLU BPLU BPLU BPLU BPLU 14-15 BPLU 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-16 14-16 SLT6200 SLT6400 SLT6600 SLVB*3210 SLVB*3210G SLVB*3210IG SLVB*3220 SLVB*3220G SLVB*3220IG SLVB*3230 BPLU 14-14 BPLU 14-14 BPLU 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SLFL36***0IGCFD6 SLFL362500CFD6 SLFL362500CGFD6 SLFL362500ICGFD6 SLFL46***0CFD6 SLFL46***0GCFD6 SLFL46***0IGCFD6 SLFL462500CFD6 SLFL462500GCFD6 SLFL462500IGCFD6 14-16 BPLU 14-16 14-16 14-16 14-16 14-16 14-16 BPLU 14-16 BPLU 14-16 BPLU 14-16 SLVB*3230G SLVB*3230IG SLVB*3240 SLVB*3240G SLVB*3240IG SLVB*3250 SLVB*3250G SLVB*3250IG SLVB*3260 SLVB*3260G 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLFL56***0CFD6 SLFL56***0CFD6 SLFL56***0GCFD6 SLFL56***0GCFD6 SLFL56***0IGCFD6 SLFL56***0IGCFD6 SLJ2600 SLJ6600 SLJC36***0GJXD6 SLJC36***0IGJXD6 14-16 14-16 14-16 14-16 14-16 14-16 BPLU 14-14 BPLU 14-14 14-15 14-15 SLVB*3260IG SLVB*3610 SLVB*3610G SLVB*3610IG SLVB*3620 SLVB*3620G SLVB*3620IG SLVB*3630 SLVB*3630G SLVB*3630IG 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SHJD69200NTH SHJD69300 SHJD69300G SHJD69300GH SHJD69300H SHJD69300NGT SHJD69300NGTH SHJD69300NT SHJD69300NTH SHJD69400 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 SHTD63F2000H SHTD63F2500 SHTD63F2500H SHTD63F3200 SHTD63F3200H SJ1 SJ1D SJ2D SJD69200 SJD69200G PBSB PBSB PBSB MCCB MCCB 6-64 6-64 6-64 6-64 6-64 10-50 10-61 10-61 6-42 6-42 SHJD69400G SHJD69400GH SHJD69400H SHJD69400NGT SHJD69400NGTH SHJD69400NT SHJD69400NTH SHLD69300 SHLD69300G SHLD69300NGT MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-46 6-46 6-46 SJD69200GH SJD69200H SJD69200NGT SJD69200NGTH SJD69200NT SJD69200NTH SJD69300 SJD69300G SJD69300GH SJD69300H MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 SLEC52***0ED2 SLEC52***0GED2 SLEC52***0GED2 SLEC52***0IGED2 SLEC52***0IGED2 SLEC54***0ED4 SLEC54***0ED4 SLEC54***0ED4 SLEC54***0GED4 SLEC54***0GED4 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLJC36***0JXD6 SLJC46***0GJXD6 SLJC46***0IGJXD6 SLJC46***0JXD6 SLJC562000GJXD6 SLJC562000IGJXD6 SLJC562000JXD6 SLJCS56***0GJXD6 SLJCS56***0IGJXD6 SLJCS56***0JXD6 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLVB*3640 SLVB*3640G SLVB*3640IG SLVB*3650 SLVB*3650G SLVB*3650IG SLVB*3660 SLVB*3660G SLVB*3660IG SLVB*4210 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SHLD69300NT SHLD69400 SHLD69400G SHLD69400NGT SHLD69400NT SHLD69500 SHLD69500G SHLD69500NGT SHLD69500NT SHLD69600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 SJD69300NGT SJD69300NGTH SJD69300NT SJD69300NTH SJD69400 SJD69400G SJD69400GH SJD69400H SJD69400NGT SJD69400NGTH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 6-42 SLEC54***0GED4 SLEC54***0IGED4 SLEC54***0IGED4 SLEC54***0IGED4 SLEC56***0ED6 SLEC56***0ED6 SLEC56***0ED6 SLEC56***0GED6 SLEC56***0GED6 SLEC56***0GED6 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLJL36***0CGJD6 SLJL36***0CJD6 SLJL36***0ICGJD6 SLJL46***0CJD6 SLJL46***0GCJD6 SLJL46***0IGCJD6 SLJL562000CJD6 SLJL562000GCJD6 SLJL562000IGCJD6 SLJLS56***0CJD6 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 SLVB*4210G SLVB*4210IG SLVB*4220 SLVB*4220G SLVB*4220IG SLVB*4230 SLVB*4230G SLVB*4230IG SLVB*4240 SLVB*4240G 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SHLD69600G SHLD69600NGT SHLD69600NT SHMD69600A SHMD69600AG SHMD69600AGH SHMD69600AH SHMD69600ANGT SHMD69600ANGTH SHMD69600ANT MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-46 6-46 6-46 6-53 6-53 6-53 6-53 6-53 6-53 6-53 SJD69400NT SJD69400NTH SL0420 SL6 SL6D SLD69300 SLD69300G SLD69300NGT SLD69300NT SLD69400 MCCB 6-42 MCCB 6-42 HDSS 3-20 PBSB 10-50 PBSB 10-61 MCCB 6-46 MCCB 6-46 MCCB 6-46 MCCB 6-46 MCCB 6-46 SLEC56***0IGED6 SLEC56***0IGED6 SLEC56***0IGED6 SLEL36***0CED6 SLEL36***0CED6 SLEL36***0CED6 SLEL36***0GCED6 SLEL36***0GCED6 SLEL36***0GCED6 SLEL36***0IGCED6 14-15 14-15 14-15 14-16 14-16 14-16 14-16 14-16 14-16 14-16 SLJLS56***0GCJD6 SLJLS56***0IGCJD6 SLLCS36***0GLXD6 SLLCS36***0IGLXD6 SLLCS36***0LXD6 SLLCS46***0GLXD6 SLLCS46***0IGLXD6 SLLCS46***0LXD6 SLLLS36***0CLD6 SLLLS36***0GCLD6 14-16 14-16 14-15 14-15 14-15 14-15 14-15 14-15 14-16 14-16 SLVB*4240IG SLVB*4250 SLVB*4250G SLVB*4250IG SLVB*4260 SLVB*4260G SLVB*4260IG SLVB*4610 SLVB*4610G SLVB*4610IG 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SHMD69600ANTH SHMD69700A SHMD69700AG SHMD69700AGH SHMD69700AH SHMD69700ANGT SHMD69700ANGTH SHMD69700ANT SHMD69700ANTH SHMD69800A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 SLD69400G SLD69400NGT SLD69400NT SLD69500 SLD69500G SLD69500NGT SLD69500NT SLD69600 SLD69600G SLD69600NGT MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 6-46 SLEL36***0IGCED6 SLEL36***0IGCED6 SLEL46***0CED6 SLEL46***0CED6 SLEL46***0CED6 SLEL46***0GCED6 SLEL46***0GCED6 SLEL46***0GCED6 SLEL46***0IGCED6 SLEL46***0IGCED6 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 SLLLS36***0IGCLD6 SLLLS46***0CLD6 SLLLS46***0GCLD6 SLLLS46***0IGCLD6 SLM1D SLM1D SLMCS36***0GMXD6 SLMCS36***0IGMXD6 SLMCS36***0MXD6 SLMCS46***0GMXD6 14-16 14-16 14-16 14-16 10-61 12-26 14-15 14-15 14-15 14-15 SLVB*4620 SLVB*4620G SLVB*4620IG SLVB*4630 SLVB*4630G SLVB*4630IG SLVB*4640 SLVB*4640G SLVB*4640IG SLVB*4650 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SHMD69800AG SHMD69800AGH SHMD69800AH SHMD69800ANGT SHMD69800ANGTH SHMD69800ANT SHMD69800ANTH SHND69100A SHND69100AG SHND69100AGH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-57 6-57 6-57 SLD69600NT SLEC32***0ED2 SLEC32***0ED2 SLEC32***0GED2 SLEC32***0GED2 SLEC32***0IGED2 SLEC32***0IGED2 SLEC34***0ED4 SLEC34***0ED4 SLEC34***0ED4 MCCB 6-46 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 SLEL46***0IGCED6 SLEL56***0CED6 SLEL56***0CED6 SLEL56***0CED6 SLEL56***0GCED6 SLEL56***0GCED6 SLEL56***0GCED6 SLEL56***0IGCED6 SLEL56***0IGCED6 SLEL56***0IGCED6 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 14-16 SLMCS46***0IGMXD6 SLMCS46***0MXD6 SLPGR3140G SLR2030 SLR2060 SLR2100 SLR2200 SLR2400 SLR2600 SLR6030 14-15 14-15 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SLVB*4650G SLVB*4650IG SLVB*4660 SLVB*4660G SLVB*4660IG SLVB*5210 SLVB*5210G SLVB*5210IG SLVB*5220 SLVB*5220G 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-17 PRODUCT INDEX MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-64 6-64 6-64 6-42 6-42 6-42 6-42 6-42 6-42 6-42 19 SHHTD63F2500H SHHTD63F3200 SHHTD63F3200H SHJD69200 SHJD69200G SHJD69200GH SHJD69200H SHJD69200NGT SHJD69200NGTH SHJD69200NT Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page SLVB*5220IG SLVB*5230 SLVB*5230G SLVB*5230IG SLVB*5240 SLVB*5240G SLVB*5240IG SLVB*5250 SLVB*5250G SLVB*5250IG 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SND69120AGH SND69120AH SND69120ANGT SND69120ANGTH SND69120ANT SND69120ANTH SND69800A SND69800AG SND69800AGH SND69800AH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 SRTDR3 SRTFF3 SRTFR3 SRTJF3 SRTJR3 SRTLF3 SRTMF3 SRTNF3 SSBP SSBPH 6-132 MCCB 6-132 6-132 6-133 6-133 6-133 6-133 6-133 MCCB 6-133 MCCB 6-133 STRLB24DC STRLB24DC STRLB24DC STRLC60DC STRLC60DC STRLC60DC STRLC60DC STRLD125DC STRLD125DC STRLD125DC MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-107 6-111 6-99 6-103 6-107 6-111 6-99 6-103 6-107 6-111 SUAT111-0PGP SUAT111-0PQG SUAT111-0PZA SUAT111-PG SUAT121-0BCO SUAT121-0GWR SUAT121-BBCO SUAT121-BGWR SUAT121-BM SUAT121-PBCO RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 SLVB*5610 SLVB*5610G SLVB*5610IG SLVB*5620 SLVB*5620G SLVB*5620IG SLVB*5630 SLVB*5630G SLVB*5630IG SLVB*5640 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 14-14 SND69800ANGT SND69800ANGTH SND69800ANT SND69800ANTH SP2211 SP2211RJ SP2211RJB SP221FK SP3311 SP3311RJ MCCB MCCB MCCB MCCB RESG RESG RESG RESG RESG RESG 6-57 6-57 6-57 6-57 2-71 2-72 2-72 2-71 2-71 2-72 SSCJ SSCJD SSCL SSCLD SSH075 SSH100 SSH125 SSH150 SSH200 SSJ1 PBSB 10-50 10-61 PBSB 10-50 PBSB 10-61 HDSS 3-20 HDSS 3-20 HDSS 3-20 HDSS 3-20 HDSS 3-20 10-50 STRLD125DC STRLE250DC STRLE250DC STRLE250DC STRLE250DC STRLM60 STRLM60 STRLM60 STRLM60 STRLN120 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-99 6-103 6-107 6-111 6-99 6-103 6-107 6-111 6-99 6-103 SUAT121-PGWR SUAT317-0FP SUAT317-0G SUAT317-0GF SUAT317-0MXA SUAT317-0PCV SUAT317-0PDN SUAT317-0PGP SUAT317-0PQG SUAT317-0PZA RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-4 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 SLVB*5640G SLVB*5640IG SLVB*5650 SLVB*5650G SLVB*5650IG SMB6 SMBKED1 SMBKED3 SMBKFD1 SMBKFD3 SP3311RJB SP331FK SP4212 SP4212RJ SP4212RJB SP4212RJL SP422FK SP4312 SP4312RJ SP4312RJB RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-72 2-71 2-71 2-72 2-72 2-73 2-71 2-71 2-72 2-72 SSJ1D SSL6 SSL6D SSMND SSMND SSMND SSMND SSRK33 SSRK34 SSRK35 PBSB 10-61 PBSB 10-50 10-61 PBSB 10-61 PBSB 10-61 PBSB 12-26 PBSB 12-26 HDSS 4-12 HDSS 4-12 HDSS 12-23 STRLN120 STRLN120 STRLN120 STRLS277 STRLS277 STRLS277 STRLS277 STRLV600 STRLV600 STRLV600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-107 6-111 6-99 6-103 6-107 6-111 6-99 6-103 6-107 6-111 SUAT317-DGZ SUAT327-0GWR SUAT327-0MCO SUAT417-0PQG SUAT417-PG SUAT417-XFP SUAT417-XG SUAT417-XGDU SUAT417-XGF SUAT417-XPQG RESG MCCB UNPB UNPB UNPB UNPB 14-14 14-14 14-14 14-14 14-14 6-87 10-12 10-12 10-12 10-12 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 SMBKJD1 SMBKJD3 SMBKLD1 SMBKLD3 SMBKQJ1 SMBKQJ3 SMD69600A SMD69600AG SMD69600AGH SMD69600AH UNPB UNPB UNPB UNPB UNPB UNPB MCCB MCCB MCCB MCCB 10-12 10-12 10-12 10-12 10-12 10-12 6-53 6-53 6-53 6-53 SP4312RJL SP432FK SP4411 SP4411RJ SP4411RJB SP4412 SP4412RJ SP4412RJB SP4412RJL SP441FK RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-73 2-71 2-71 2-72 2-72 2-71 2-72 2-72 2-73 2-71 SSRK36 STD20TLI STD20TLIG STD20TLS STD20TLSG STD20TLSI STD20TLSIG STD32TCON STD63F2000 STD63F2000H HDSS 12-23 6-64 6-64 6-64 6-64 6-64 6-64 MCCB 6-64 6-64 6-64 STRLV600 STRPB24DC STRPB24DC STRPB24DC STRPC60DC STRPC60DC STRPC60DC STRPD125DC STRPD125DC STRPD125DC MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-99 6-115 6-119 6-122 6-115 6-119 6-122 6-115 6-119 6-122 SUAT427-PMCO SUAT427-XMWR SUAT517-PDG SUAT618-XGNM SUK1000TA SUK350TA SUK600TA SX302A10F SX302A10P SX302A10R SMD69600ANGT SMD69600ANGTH SMD69600ANT SMD69600ANTH SMD69700A SMD69700AG SMD69700AGH SMD69700AH SMD69700ANGT SMD69700ANGTH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 SP442FK SP4511 SP4511RJ SP4511RJB SP4561FK SP4611 SP4611RJ SP4611RJB SP5411 SP6412 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-71 2-71 2-72 2-72 2-71 2-71 2-72 2-72 2-71 2-71 STD63F2500 STD63F2500H STD63F3200 STD63F3200H STDAPM STDAS STDAS10 STDAS12 STDAS2 STDAS4 6-64 6-64 6-64 6-64 6-65 6-65 6-65 6-65 6-65 6-65 STRPE250DC STRPE250DC STRPE250DC STRPM60 STRPM60 STRPM60 STRPN120 STRPN120 STRPN120 STRPS277 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-115 6-119 6-122 6-115 6-119 6-122 6-115 6-119 6-122 6-115 SX302A10R SX302A14F SX302A14P SX302A19F SX302A20F SX302A20P SX302A20R SX302A24F SX302A24P SX302A24R 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SMD69700ANT SMD69700ANTH SMD69800A SMD69800AG SMD69800AGH SMD69800AH SMD69800ANGT SMD69800ANGTH SMD69800ANT SMD69800ANTH MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 6-53 SP642FK SP6511 SP6511RJ SP6511RJB SP6512 SP6512RJ SP6512RJB SP6512RJL SP6561FK SP6562FK RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-71 2-71 2-72 2-72 2-71 2-72 2-72 2-73 2-71 2-71 STDAS6 STDAS8 STDBA120 STDBA125 STDBA24 STDBA48 STDDM STDDMR120 STDDMR125 STDDMR24 6-65 6-65 6-65 6-65 6-65 6-65 6-65 6-65 6-65 6-65 STRPS277 STRPS277 STRPV600 STRPV600 STRPV600 SUA2311-0PGP SUA2311-0PQG SUA2717-YPDN SUA2717-YPGP SUA2717-YPQG MCCB MCCB MCCB MCCB MCCB RESG RESG RESG RESG RESG 6-119 6-122 6-115 6-119 6-122 2-6 2-6 2-6 2-6 2-6 SX302A29F SX302A30F SX302A30P SX302A30R SX302A34F SX302A34P SX302A34R SX302A39F SX302C10F SX302C10P 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-8 14-8 SMF SMF SMF SMLKA1 SMLKA3 SMMBQMK SMMCEMK SMMEDMK SMMFDMK SMMHEMK NEMA NEMA NEMA UNPB UNPB 16-150 16-6 16-79 10-12 10-12 12-26 12-26 12-26 12-26 12-26 SP6611 SP6611RJ SP6611RJB SP6612 SP6612RJ SP6612RJB SP6612RJL SP8612 SP8612RJ SPD69140 RESG RESG RESG RESG RESG RESG RESG RESG MCCB 2-71 2-72 2-72 2-71 2-72 2-72 2-73 2-71 2-72 6-60 STDDMR48 STDGFM STDMIF32 STDPLD STDST12 STDST120 STDST125 STDST24 STDST240 STDST48 6-65 6-65 6-87 6-86 6-65 6-65 6-65 6-65 6-65 6-65 SUA2717-YPZA SUA3311-0PGP SUA3311-0PQG SUA3717-YPDN SUA3717-YPGP SUA3717-YPZA SUA4311-0PGP SUA4311-0PQG SUA4719-YPDN SUA4719-YPGP RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 SX302C10R SX302C14F SX302C14P SX302C14R SX302C19F SX302C20F SX302C20P SX302C20R SX302C24F SX302C24P 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SMMNGMK SMMQJMK SMMTFMK SMND SMND SMND SMND SNB SNBD SNBD 12-26 12-26 12-26 10-61 10-61 12-26 12-26 PBSB 10-50 PBSB 10-61 PBSB 12-26 SPD69140G SPD69140NGT SPD69140NT SPD69160 SPD69160G SPD69160NGT SPD69160NT SQJ SQJD SRSS MCCB 6-60 MCCB 6-60 MCCB 6-60 MCCB 6-60 MCCB 6-60 MCCB 6-60 MCCB 6-60 PBSB 10-50 PBSB 10-61 RESG 2-10 6-65 6-65 6-65 6-65 6-65 6-65 6-65 6-65 6-65 6-65 SUA4719-YPQG SUA4719-YPZA SUA5719-KPDN SUA5719-KPGP SUA6719-KPQG SUA6719-KPZA SUAS817-PPGP SUAS818-PGNM SUAS877-PG SUAS877-PPCV RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-6 2-6 2-6 2-6 2-6 2-6 2-5 2-5 2-5 2-5 SX302C24R SX302C29F SX302C30F SX302C30P SX302C30R SX302C34F SX302C34P SX302C34R SX302C39F SX304A10F 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-5 SND69100A SND69100AG SND69100AGH SND69100AH SND69100ANGT SND69100ANGTH SND69100ANT SND69100ANTH SND69120A SND69120AG MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB SRSS SRSS SRSTD SRSTD SRSTD SRSW SRSW SRSW SRSW SRTDF3 6-65 6-65 6-65 6-25 6-33 6-25 6-33 6-25 6-33 6-103 SUAS877-PPDN SUAS877-PPGP SUAS877-PPZ SUAS877-PPZA SUAS917-XJCA SUAT111-0G SUAT111-0GF SUAT111-0JCA SUAT111-0MXA SUAT111-0PDN RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-5 2-5 2-5 2-5 2-5 2-4 2-4 2-4 2-4 2-4 SX304A10P SX304A10R SX304A14F SX304A14P SX304A14R SX304A19F SX304A20F SX304A20P SX304A20R SX304A24F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 19-18 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 6-57 RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-74 2-81 2-10 2-26 2-81 2-10 2-26 2-74 2-81 6-132 STDST480 STDTBLB STDTBLT STDTBM STDTBRB STDTBRT STDUV120 STDUV125 STDUV24 STDUV240 STDUV48 STDUV480 STDUV600 STREM60D STREM60D STRER240 STRER240 STREV600 STREV600 STRLB24DC MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-5 2-5 2-5 2-5 2-74 2-74 2-74 14-5 14-5 14-5 Product Index Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page SX308A30P SX308A30R SX308A30R SX308A34F SX308A34F SX308A34P SX308A34P SX308A34R SX308A34R SX308A39F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX312A30R SX312A34F SX312A34P SX312A34R SX312A39F SX312C10F SX312C10P SX312C10R SX312C14F SX312C14P 14-6 14-6 14-6 14-6 14-6 14-9 14-9 14-9 14-9 14-9 SX316C10P SX316C10R SX316C14F SX316C14P SX316C14R SX316C19F SX316C20F SX316C20P SX316C20R SX316C24F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX325C20F SX325C20P SX325C20R SX325C24F SX325C24P SX325C24R SX325C29F SX325C30F SX325C30P SX325C30R 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX304C10F SX304C10P SX304C10R SX304C14F SX304C14P SX304C14R SX304C19F SX304C20F SX304C20P SX304C20R 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX308A39F SX308C10F SX308C10P SX308C10R SX308C14F SX308C14P SX308C14R SX308C19F SX308C20F SX308C20P 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX312C14R SX312C19F SX312C20F SX312C20P SX312C20R SX312C24F SX312C24P SX312C24R SX312C29F SX312C30F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX316C24P SX316C24R SX316C29F SX316C30F SX316C30P SX316C30R SX316C34F SX316C34P SX316C34R SX316C39F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX325C34F SX325C34P SX325C34R SX325C39F SX330A10F SX330A10P SX330A10R SX330A14F SX330A14P SX330A14R 14-9 14-9 14-9 14-9 14-7 14-7 14-7 14-7 14-7 14-7 SX304C24F SX304C24P SX304C24R SX304C29F SX304C30F SX304C30P SX304C30R SX304C34F SX304C34P SX304C34R 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX308C20R SX308C24F SX308C24P SX308C24R SX308C29F SX308C30F SX308C30P SX308C30R SX308C34F SX308C34P 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX312C30P SX312C30R SX312C34F SX312C34P SX312C34R SX312C39F SX313A10F SX313A10F SX313A10P SX313A10P 14-9 14-9 14-9 14-9 14-9 14-9 14-6 14-6 14-6 14-6 SX320A10F SX320A10P SX320A10R SX320A14F SX320A14P SX320A14R SX320A19F SX320A20F SX320A20P SX320A20R 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX330A19F SX330A20F SX330A20P SX330A20R SX330A24F SX330A24P SX330A24R SX330A29F SX330A30F SX330A30P 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX304C39F SX306A10F SX306A10P SX306A10R SX306A14F SX306A14P SX306A14R SX306A19F SX306A20F SX306A20P 14-8 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX308C34R SX308C39F SX310A10F SX310A10P SX310A10R SX310A14F SX310A14P SX310A14R SX310A19F SX310A20F 14-8 14-8 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX313A10R SX313A10R SX313A14F SX313A14F SX313A14P SX313A14P SX313A14R SX313A14R SX313A19F SX313A19F 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX320A24F SX320A24P SX320A24R SX320A29F SX320A30F SX320A30P SX320A30R SX320A34F SX320A34P SX320A34R 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX330A30R SX330A34F SX330A34P SX330A34R SX330A39F SX330C10F SX330C10P SX330C10R SX330C14F SX330C14P 14-7 14-7 14-7 14-7 14-7 14-10 14-10 14-10 14-10 14-10 SX306A20R SX306A24F SX306A24P SX306A24R SX306A29F SX306A30F SX306A30P SX306A30R SX306A34F SX306A34P 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX310A20P SX310A20R SX310A24F SX310A24P SX310A24R SX310A29F SX310A30F SX310A30P SX310A30R SX310A34F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX313A30F SX313A30P SX313A30R SX313A34F SX313A34P SX313A34R SX313A39F SX313C10F SX313C10P SX313C10R 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-9 14-9 14-9 SX320A39F SX320C10F SX320C10P SX320C10R SX320C14F SX320C14P SX320C14R SX320C19F SX320C20F SX320C20P 14-6 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX330C14R SX330C19F SX330C20F SX330C20P SX330C20R SX330C24F SX330C24P SX330C24R SX330C29F SX330C30F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX306A34R SX306A39F SX306C10F SX306C10P SX306C10R SX306C14F SX306C14P SX306C14R SX306C19F SX306C20F 14-5 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX310A34P SX310A34R SX310A39F SX310C10F SX310C10P SX310C10R SX310C14F SX310C14P SX310C14R SX310C19F 14-5 14-5 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX313C14F SX313C14P SX313C14R SX313C19F SX313C20F SX313C20P SX313C20R SX313C24F SX313C24P SX313C24R 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX320C20R SX320C24F SX320C24P SX320C24R SX320C29F SX320C30F SX320C30P SX320C30R SX320C34F SX320C34P 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX330C30P SX330C30R SX330C34F SX330C34P SX330C34R SX330C39F SX332A10F SX332A10P SX332A10R SX332A14F 14-10 14-10 14-10 14-10 14-10 14-10 14-7 14-7 14-7 14-7 SX306C20P SX306C20R SX306C24F SX306C24P SX306C24R SX306C29F SX306C30F SX306C30P SX306C30R SX306C34F 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX310C20F SX310C20P SX310C20R SX310C24F SX310C24P SX310C24R SX310C29F SX310C30F SX310C30P SX310C30R 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX313C29F SX313C30F SX313C30P SX313C30R SX313C34F SX313C34P SX313C34R SX313C39F SX316A10F SX316A10P 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-6 14-6 SX320C34R SX320C39F SX325A10F SX325A10P SX325A10R SX325A14F SX325A14P SX325A14R SX325A19F SX325A20F 14-9 14-9 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX332A14P SX332A14R SX332A19F SX332A20F SX332A20P SX332A20R SX332A24F SX332A24P SX332A24R SX332A29F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX306C34P SX306C34R SX306C39F SX308A10F SX308A10P SX308A10R SX308A14F SX308A14P SX308A14R SX308A19F 14-8 14-8 14-8 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX310C34F SX310C34P SX310C34R SX310C39F SX312A10F SX312A10P SX312A10R SX312A14F SX312A14P SX312A14R 14-8 14-8 14-8 14-8 14-6 14-6 14-6 14-6 14-6 14-6 SX316A10R SX316A14F SX316A14P SX316A14R SX316A19F SX316A20F SX316A20P SX316A20R SX316A24F SX316A24P 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX325A20P SX325A20R SX325A24F SX325A24P SX325A24R SX325A29F SX325A30F SX325A30P SX325A30R SX325A34F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX332A30F SX332A30P SX332A30R SX332A34F SX332A34P SX332A34R SX332A39F SX332C10F SX332C10P SX332C10R 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-10 14-10 14-10 SX308A20F SX308A20P SX308A20R SX308A24F SX308A24P SX308A24R SX308A29F SX308A30F SX308A30F SX308A30P 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX312A19F SX312A20F SX312A20P SX312A20R SX312A24F SX312A24P SX312A24R SX312A29F SX312A30F SX312A30P 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX316A24R SX316A29F SX316A30F SX316A30P SX316A30R SX316A34F SX316A34P SX316A34R SX316A39F SX316C10F 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-9 SX325A34P SX325A34R SX325A39F SX325C10F SX325C10P SX325C10R SX325C14F SX325C14P SX325C14R SX325C19F 14-7 14-7 14-7 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX332C14F SX332C14P SX332C14R SX332C19F SX332C20F SX332C20P SX332C20R SX332C24F SX332C24P SX332C24R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-19 PRODUCT INDEX 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 19 SX304A24P SX304A24R SX304A29F SX304A30F SX304A30P SX304A30R SX304A34F SX304A34P SX304A34R SX304A39F Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page SX332C29F SX332C30F SX332C30P SX332C30R SX332C34F SX332C34P SX332C34R SX332C39F SX340A10F SX340A10P 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-7 14-7 SX402A34R SX402A39F SX402C10F SX402C10P SX402C10R SX402C14F SX402C14P SX402C14R SX402C19F SX402C20F 14-5 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX406C14P SX406C14R SX406C19F SX406C20F SX406C20P SX406C20R SX406C24F SX406C24P SX406C24R SX406C29F 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX410C34F SX410C34P SX410C34R SX410C39F SX412A10F SX412A10P SX412A10R SX412A14F SX412A14P SX412A14R 14-8 14-8 14-8 14-8 14-6 14-6 14-6 14-6 14-6 14-6 SX416A10R SX416A14F SX416A14P SX416A14R SX416A19F SX416A20F SX416A20P SX416A20R SX416A24F SX416A24P 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX340A10R SX340A14F SX340A14P SX340A14R SX340A19F SX340A20F SX340A20P SX340A20R SX340A24F SX340A24P 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX402C20P SX402C20R SX402C24F SX402C24P SX402C24R SX402C29F SX402C30F SX402C30P SX402C30R SX402C34F 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX406C30F SX406C30P SX406C30R SX406C34F SX406C34P SX406C34R SX406C39F SX408A20F SX408A20P SX408A20R 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-5 14-5 14-5 SX412A19F SX412A20F SX412A20P SX412A20R SX412A24F SX412A24P SX412A24R SX412A29F SX412A30F SX412A30P 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX416A24R SX416A29F SX416A30F SX416A30P SX416A30R SX416A34F SX416A34P SX416A34R SX416A39F SX416C10F 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-9 SX340A24R SX340A29F SX340A30F SX340A30P SX340A30R SX340A34F SX340A34P SX340A34R SX340A39F SX340C10F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-10 SX402C34P SX402C34R SX402C39F SX404A10F SX404A10P SX404A10R SX404A14F SX404A14P SX404A14R SX404A19F 14-8 14-8 14-8 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX408A24F SX408A24P SX408A24R SX408A29F SX408A30F SX408A30P SX408A30R SX408A34F SX408A34P SX408A34R 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX412A30R SX412A34F SX412A34P SX412A34R SX412A39F SX412C10F SX412C10P SX412C10R SX412C14F SX412C14P 14-6 14-6 14-6 14-6 14-6 14-9 14-9 14-9 14-9 14-9 SX416C10P SX416C10R SX416C14F SX416C14P SX416C14R SX416C19F SX416C20F SX416C20P SX416C20R SX416C24F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX340C10P SX340C10R SX340C14F SX340C14P SX340C14R SX340C19F SX340C20F SX340C20P SX340C20R SX340C24F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX404A20F SX404A20P SX404A20R SX404A24F SX404A24P SX404A24R SX404A29F SX404A30F SX404A30P SX404A30R 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX408A39F SX408C10F SX408C10P SX408C10R SX408C14F SX408C14P SX408C14R SX408C19F SX408C20F SX408C20P 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX412C14R SX412C19F SX412C20F SX412C20P SX412C20R SX412C24F SX412C24P SX412C24R SX412C29F SX412C30F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX416C24P SX416C24R SX416C29F SX416C30F SX416C30P SX416C30R SX416C34F SX416C34P SX416C34R SX416C39F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX340C24P SX340C24R SX340C29F SX340C30F SX340C30P SX340C30R SX340C34F SX340C34P SX340C34R SX340C39F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX404A34F SX404A34P SX404A34R SX404A39F SX404C10F SX404C10P SX404C10P SX404C14F SX404C14P SX404C14R 14-5 14-5 14-5 14-5 14-8 14-8 14-8 14-8 14-8 14-8 SX408C20R SX408C24F SX408C24P SX408C24R SX408C29F SX408C30F SX408C30P SX408C30R SX408C34F SX408C34P 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX412C30P SX412C30R SX412C34F SX412C34P SX412C34R SX412C39F SX413A10F SX413A10P SX413A10R SX413A14F 14-9 14-9 14-9 14-9 14-9 14-9 14-6 14-6 14-6 14-6 SX420A10F SX420A10P SX420A10R SX420A14F SX420A14P SX420A14R SX420A19F SX420A20F SX420A20P SX420A20R 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX350C10F SX350C10P SX350C10R SX350C14F SX350C14P SX350C14R SX350C19F SX350C20F SX350C20P SX350C20R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX404C19F SX404C20F SX404C20P SX404C20R SX404C24F SX404C24P SX404C24R SX404C29F SX404C30F SX404C30P 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX408C34R SX408C39F SX410A10F SX410A10P SX410A10R SX410A14F SX410A14P SX410A14R SX410A19F SX410A20F 14-8 14-8 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX413A14P SX413A14R SX413A19F SX413A20F SX413A20P SX413A20R SX413A24F SX413A24P SX413A24R SX413A29F 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX420A24F SX420A24P SX420A24R SX420A29F SX420C10F SX420C10P SX420C10R SX420C14F SX420C14P SX420C14R 14-6 14-6 14-6 14-6 14-9 14-9 14-9 14-9 14-9 14-9 SX350C24F SX350C24P SX350C24R SX350C29F SX350C30F SX350C30P SX350C30R SX350C34F SX350C34P SX350C34R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX404C30R SX404C34F SX404C34P SX404C34R SX404C39F SX406A10F SX406A10P SX406A10R SX406A14F SX406A14P 14-8 14-8 14-8 14-8 14-8 14-5 14-5 14-5 14-5 14-5 SX410A20P SX410A20R SX410A24F SX410A24P SX410A24R SX410A29F SX410A30F SX410A30P SX410A30R SX410A34F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX413A30F SX413A30P SX413A30R SX413A34F SX413A34P SX413A34R SX413A39F SX413C10F SX413C10P SX413C10R 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-9 14-9 14-9 SX420C19F SX420C20F SX420C20P SX420C20R SX420C24F SX420C24P SX420C24R SX420C29F SX420C30F SX420C30P 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX350C39F SX402A10F SX402A10P SX402A10R SX402A14F SX402A14P SX402A14R SX402A19F SX402A20F SX402A20P 14-10 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX406A14R SX406A19F SX406A20F SX406A20P SX406A20R SX406A24F SX406A24P SX406A24R SX406A29F SX406A30F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX410A34P SX410A34R SX410A39F SX410C10F SX410C10P SX410C10R SX410C14F SX410C14P SX410C14R SX410C19F 14-5 14-5 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX413C14F SX413C14P SX413C14R SX413C19F SX413C20F SX413C20P SX413C20R SX413C24F SX413C24P SX413C24R 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX420C30R SX420C34F SX420C34P SX420C34R SX420C39F SX425A10F SX425A10P SX425A10R SX425A14F SX425A14P 14-9 14-9 14-9 14-9 14-9 14-7 14-7 14-7 14-7 14-7 SX402A20R SX402A24F SX402A24P SX402A24R SX402A29F SX402A30F SX402A30P SX402A30R SX402A34F SX402A34P 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX406A30P SX406A30R SX406A34F SX406A34P SX406A34R SX406A39F SX406C10F SX406C10P SX406C10R SX406C14F 14-5 14-5 14-5 14-5 14-5 14-5 14-8 14-8 14-8 14-8 SX410C20F SX410C20P SX410C20R SX410C24F SX410C24P SX410C24R SX410C29F SX410C30F SX410C30P SX410C30R 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX413C29F SX413C30F SX413C30P SX413C30R SX413C34F SX413C34P SX413C34R SX413C39F SX416A10F SX416A10P 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-6 14-6 SX425A14R SX425A19F SX425A20F SX425A20P SX425A20R SX425A24F SX425A24P SX425A24R SX425A29F SX425A30F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 19-20 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Product Index Catalog Number Product Class Page Catalog Number Product Class Page Catalog Number Product Class Page Catalog Number Product Class Page Catalog Number Product Class Page SX432A30F SX432A30P SX432A30R SX432A34F SX432A34P SX432A34R SX432A39F SX432C10F SX432C10P SX432C10R 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-10 14-10 14-10 SX450C29F SX450C30F SX450C30P SX450C30R SX450C34F SX450C34P SX450C34R SX450C39F SX502A10F SX502A10P 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-5 14-5 SX504C34R SX504C39F SX506A10F SX506A10P SX506A10R SX506A14F SX506A14P SX506A14R SX506A19F SX506A20F 14-8 14-8 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX510A14P SX510A14R SX510A19F SX510A20F SX510A20P SX510A20R SX510A24F SX510A24P SX510A24R SX510A29F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX425C14P SX425C14R SX425C19F SX425C20F SX425C20P SX425C20R SX425C24F SX425C24P SX425C24R SX425C29F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX432C14F SX432C14P SX432C14R SX432C19F SX432C20F SX432C20P SX432C20R SX432C24F SX432C24P SX432C24R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX502A10R SX502A14F SX502A14P SX502A14R SX502A19F SX502A20F SX502A20P SX502A20R SX502A24F SX502A24P 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX506A20P SX506A20R SX506A24F SX506A24P SX506A24R SX506A29F SX506A30F SX506A30P SX506A30R SX506A34F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX510A30F SX510A30P SX510A30R SX510A34F SX510A34P SX510A34R SX510A39F SX510C10F SX510C10P SX510C10R 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-8 14-8 14-8 SX425C30F SX425C30P SX425C30R SX425C34F SX425C34P SX425C34R SX425C39F SX430A10F SX430A10P SX430A10R 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-7 14-7 14-7 SX432C29F SX432C30F SX432C30P SX432C30R SX432C34F SX432C34P SX432C34R SX432C39F SX440A10F SX440A10F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-7 14-7 SX502A24R SX502A29F SX502A30F SX502A30P SX502A30R SX502A34F SX502A34P SX502A34R SX502A39F SX502C10F 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-8 SX506A34P SX506A34R SX506A39F SX506C10F SX506C10P SX506C10R SX506C14F SX506C14P SX506C14R SX506C19F 14-5 14-5 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX510C14F SX510C14P SX510C14R SX510C19F SX510C20F SX510C20P SX510C20R SX510C24F SX510C24P SX510C24R 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX430A14F SX430A14P SX430A14R SX430A19F SX430A20F SX430A20P SX430A20R SX430A24F SX430A24P SX430A24R 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX440A10P SX440A10P SX440A10R SX440A10R SX440A14F SX440A14F SX440A14P SX440A14P SX440A14R SX440A14R 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX502C10P SX502C10R SX502C14F SX502C14P SX502C14R SX502C19F SX502C20F SX502C20P SX502C20R SX502C24F 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX506C20F SX506C20P SX506C20R SX506C24F SX506C24P SX506C24R SX506C29F SX506C30F SX506C30P SX506C30R 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX510C29F SX510C30F SX510C30P SX510C30R SX510C34F SX510C34P SX510C34R SX510C39F SX512A10F SX512A10P 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-6 14-6 SX430A29F SX430A30F SX430A30P SX430A30R SX430A34F SX430A34P SX430A34R SX430A39F SX430C10F SX430C10P 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-10 14-10 SX440A19F SX440A19F SX440A20F SX440A20P SX440A20R SX440A24F SX440A24P SX440A24R SX440A29F SX440A30F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX502C24P SX502C24R SX502C29F SX502C30F SX502C30P SX502C30R SX502C34F SX502C34P SX502C34R SX502C39F 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX506C34F SX506C34P SX506C34R SX506C39F SX508A10F SX508A10P SX508A10R SX508A14F SX508A14P SX508A14R 14-8 14-8 14-8 14-8 14-5 14-5 14-5 14-5 14-5 14-5 SX512A10R SX512A14F SX512A14P SX512A14R SX512A19F SX512A20F SX512A20P SX512A20R SX512A24F SX512A24P 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX430C10R SX430C14F SX430C14P SX430C14R SX430C19F SX430C20F SX430C20P SX430C20R SX430C24F SX430C24P 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX440A30P SX440A30R SX440A34F SX440A34P SX440A34R SX440A39F SX440C10F SX440C10P SX440C10R SX440C14F 14-7 14-7 14-7 14-7 14-7 14-7 14-10 14-10 14-10 14-10 SX504A10F SX504A10P SX504A10R SX504A14F SX504A14P SX504A14R SX504A19F SX504A20F SX504A20P SX504A20R 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX508A19F SX508A20F SX508A20P SX508A20R SX508A24F SX508A24P SX508A24R SX508A29F SX508A30F SX508A30P 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX512A24R SX512A29F SX512A30F SX512A30P SX512A30R SX512A34F SX512A34P SX512A34R SX512A39F SX512C10F 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-9 SX430C24R SX430C29F SX430C30F SX430C30P SX430C30R SX430C34F SX430C34P SX430C34R SX430C39F SX432A10F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-7 SX440C14P SX440C14R SX440C19F SX440C20F SX440C20P SX440C20R SX440C24F SX440C24P SX440C24R SX440C29F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX504A24F SX504A24P SX504A24R SX504A29F SX504A30F SX504A30P SX504A30R SX504A34F SX504A34P SX504A34R 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 14-5 SX508A30R SX508A34F SX508A34P SX508A34R SX508A39F SX508C10F SX508C10P SX508C10R SX508C14F SX508C14P 14-5 14-5 14-5 14-5 14-5 14-8 14-8 14-8 14-8 14-8 SX512C10P SX512C10R SX512C14F SX512C14P SX512C14R SX512C19F SX512C20F SX512C20P SX512C20R SX512C24F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX432A10F SX432A10F SX432A10P SX432A10P SX432A10P SX432A10R SX432A10R SX432A10R SX432A14F SX432A14F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX440C30F SX440C30P SX440C30R SX440C34F SX440C34P SX440C34R SX440C39F SX450C10F SX450C10P SX450C10R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX504A39F SX504C10F SX504C10P SX504C10R SX504C14F SX504C14P SX504C14R SX504C19F SX504C20F SX504C20P 14-5 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX508C14R SX508C19F SX508C20F SX508C20P SX508C20R SX508C24F SX508C24P SX508C24R SX508C29F SX508C30F 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX512C24P SX512C24R SX512C29F SX512C30F SX512C30P SX512C30R SX512C34F SX512C34P SX512C34R SX512C39F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX432A14F SX432A14P SX432A14P SX432A14P SX432A14R SX432A14R SX432A14R SX432A19F SX432A19F SX432A19F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX450C14F SX450C14P SX450C14R SX450C19F SX450C20F SX450C20P SX450C20R SX450C24F SX450C24P SX450C24R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX504C20R SX504C24F SX504C24P SX504C24R SX504C29F SX504C30F SX504C30P SX504C30R SX504C34F SX504C34P 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 14-8 SX508C30P SX508C30R SX508C34F SX508C34P SX508C34R SX508C39F SX510A10F SX510A10P SX510A10R SX510A14F 14-8 14-8 14-8 14-8 14-8 14-8 14-5 14-5 14-5 14-5 SX513A10F SX513A10P SX513A10R SX513A14F SX513A14P SX513A14R SX513A19F SX513A20F SX513A20P SX513A20R 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-21 PRODUCT INDEX 14-7 14-7 14-7 14-7 14-7 14-7 14-9 14-9 14-9 14-9 19 SX425A30P SX425A30R SX425A34F SX425A34P SX425A34R SX425A39F SX425C10F SX425C10P SX425C10R SX425C14F Product Index PRODUCT INDEX 19 Catalog Number Product Class Page Catalog Number Product Class Page Catalog Number Product Class Page Catalog Number Product Class Page Catalog Number Product Class Page SX513A24F SX513A24P SX513A24R SX513A29F SX513A30F SX513A30P SX513A30R SX513A34F SX513A34P SX513A34R 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX520A24P SX520A24R SX520A24R SX520A29F SX520A29F SX520A30F SX520A30P SX520A30R SX520A34F SX520A34P 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX530A30P SX530A30R SX530A34F SX530A34P SX530A34R SX530A39F SX530C10F SX530C10P SX530C10R SX530C14F 14-7 14-7 14-7 14-7 14-7 14-7 14-10 14-10 14-10 14-10 SX540C30F SX540C30P SX540C30R SX540C34F SX540C34P SX540C34R SX540C39F SX550C10F SX550C10P SX550C10R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 TA2J630 TA2J630 TA2J6500 TA2J6500 TA2J6500 TA2J6500 TA2J6500 TA2J6500 TA2JG250 TA2K500 MCCB 6-42 MCCB 6-82 MCCB 6-40 MCCB 6-42 MCCB 6-42 MCCB 6-44 MCCB 6-82 MCCB 6-82 MCCB 6-135 MCCB 4-22 SX513A39F SX513C10F SX513C10P SX513C10R SX513C14F SX513C14P SX513C14R SX513C19F SX513C20F SX513C20P 14-6 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX520A34R SX520A39F SX520C10F SX520C10P SX520C10R SX520C14F SX520C14P SX520C14R SX520C19F SX520C20F 14-6 14-6 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX530C14P SX530C14R SX530C19F SX530C20F SX530C20P SX530C20R SX530C24F SX530C24P SX530C24R SX530C29F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SX550C14F SX550C14P SX550C14R SX550C19F SX550C20F SX550C20P SX550C20R SX550C24F SX550C24P SX550C24R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 TA2K500 TA2K500 TA2K500 TA2K500 TA2K500 TA2MG750 TA2N750 TA2N750 TA3DG02 TA3FG20 MCCB 6-48 MCCB 6-51 MCCB 6-53 MCCB 6-55 MCCB 6-82 MCCB 6-135 MCCB 6-48 MCCB 6-82 6-134 6-134 SX513C20R SX513C24F SX513C24P SX513C24R SX513C29F SX513C30F SX513C30P SX513C30R SX513C34F SX513C34P 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX520C20P SX520C20R SX520C24F SX520C24P SX520C24R SX520C29F SX520C30F SX520C30P SX520C30R SX520C34F 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX530C30F SX530C30P SX530C30R SX530C34F SX530C34P SX530C34R SX530C39F SX532A20F SX532A20P SX532A20R 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-7 14-7 14-7 SX550C29F SX550C30F SX550C30P SX550C30R SX550C34F SX550C34P SX550C34R SX550C39F SXBAT SXDRA1 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-12 14-12 TA3H750 TA3K500 TA3K500 TA3K500 TA3K500 TA3K500 TA3K500 TA3MG500 TA3NG750 TA4H500 MCCB 4-22 MCCB 4-22 MCCB 6-48 MCCB 6-51 MCCB 6-53 MCCB 6-55 MCCB 6-82 MCCB 6-135 6-135 MCCB 4-22 SX513C34R SX513C39F SX516A10F SX516A10P SX516A10R SX516A14F SX516A14P SX516A14R SX516A19F SX516A20F 14-9 14-9 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX520C34P SX520C34R SX520C39F SX525A10F SX525A10P SX525A10R SX525A14F SX525A14P SX525A14R SX525A19F 14-9 14-9 14-9 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX532A24F SX532A24P SX532A24R SX532A29F SX532A30F SX532A30P SX532A30R SX532A34F SX532A34P SX532A34R 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SXDRA2 SXDRA3 SXDRA4 SXDRA5 SXDRA6 SXDRA7 SXDRC1 SXDRC2 SXDRC3 SXDRC4 14-12 14-12 14-12 14-12 14-12 14-12 14-12 14-12 14-12 14-12 TA4P750 TA4P750 TA4P750 TA4P750 TA4P750 TA5P600 TA5P600 TA5P600 TA5P600 TA5P600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB SX516A20P SX516A20R SX516A24F SX516A24P SX516A24R SX516A29F SX516A30F SX516A30P SX516A30R SX516A34F 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX525A20F SX525A20P SX525A20R SX525A24F SX525A24P SX525A24R SX525A29F SX525A30F SX525A30P SX525A30R 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX532A39F SX532C10F SX532C10P SX532C10R SX532C14F SX532C14P SX532C14R SX532C19F SX532C20F SX532C20P 14-7 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SXDRC5 SXDRC6 SXDRC7 SXLK SXSB SXSH10 SXSH12 SXSH14 SXSH4 SXSH6 14-12 14-12 14-12 14-12 14-12 14-12 14-12 14-12 14-12 14-12 TA5P600 TA5P600 TA5P600 TA5P600 TA6DG04 TA6ED06 TA6FD04 TA6FG04 TA6JD20 TA6JG20 MCCB MCCB MCCB MCCB 6-59 6-60 6-62 6-82 6-134 MCCB 6-83 MCCB 6-83 6-134 MCCB 6-83 6-135 SX516A34P SX516A34R SX516A39F SX516C10F SX516C10P SX516C10R SX516C14F SX516C14P SX516C14R SX516C19F 14-6 14-6 14-6 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX525A34F SX525A34P SX525A34R SX525A39F SX525C10F SX525C10P SX525C10R SX525C14F SX525C14P SX525C14R 14-7 14-7 14-7 14-7 14-9 14-9 14-9 14-9 14-9 14-9 SX532C20R SX532C24F SX532C24P SX532C24R SX532C29F SX532C30F SX532C30P SX532C30R SX532C34F SX532C34P 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 SXSH8 SXSK SXSK SXSS1 SXSS2 SXSS3 SXSS4 SXTH1 SXTH2 SXTH3 TA6R600 TA6R600 TA6R600 TA6R600 TA6R600 TA6R600 TA6R600STD TAW1FG350 TBTH TBTH202R MCCB 6-120 MCCB 6-135 MCCB 6-59 MCCB 6-60 MCCB 6-62 MCCB 6-82 6-64 MCCB 6-134 BPLU 14-61 BPLU 14-61 SX516C20F SX516C20P SX516C20R SX516C24F SX516C24P SX516C24R SX516C29F SX516C30F SX516C30P SX516C30R 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX525C19F SX525C20F SX525C20P SX525C20R SX525C24F SX525C24P SX525C24R SX525C29F SX525C30F SX525C30P 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 14-9 SX532C34R SX532C39F SX540A20F SX540A20P SX540A20R SX540A24F SX540A24P SX540A24R SX540A29F SX540A30F 14-10 14-10 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SXTH4 SXWH1 SXWH2 SXWH3 SXWH4 T131 T132 T134 T25 T331 14-12 14-12 14-12 14-12 14-12 14-61 14-61 14-61 14-61 14-61 TBTH302F TBTH306F TC1DG30 TC1ED6150 TC1FD350 TC1FD350 TC1J6600 TC1J6600 TC1J6600 TC1J6600 BPLU 14-61 BPLU 14-61 6-134 MCCB 6-83 MCCB 6-37 MCCB 6-83 MCCB 6-40 MCCB 6-42 MCCB 6-44 MCCB 6-83 SX516C34F SX516C34P SX516C34R SX516C39F SX520A10F SX520A10P SX520A10R SX520A14F SX520A14P SX520A14R 14-9 14-9 14-9 14-9 14-6 14-6 14-6 14-6 14-6 14-6 SX525C30R SX525C34F SX525C34P SX525C34R SX525C39F SX530A10F SX530A10P SX530A10R SX530A14F SX530A14P 14-9 14-9 14-9 14-9 14-9 14-7 14-7 14-7 14-7 14-7 SX540A30P SX540A30R SX540A34F SX540A34P SX540A34R SX540A39F SX540C10F SX540C10P SX540C10R SX540C14F 14-7 14-7 14-7 14-7 14-7 14-7 14-10 14-10 14-10 14-10 T332 T334 T35 T431 TA12JG04 TA1DG30 TA1E6125 TA1E6125 TA1FD350A TA1FD350A BUSW BUSW BUSW BUSW 14-61 14-61 14-61 14-62 6-135 6-134 6-82 6-82 6-37 6-82 TC1JG750 TC1JG750 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q250 TC2J6500 TC2J6500 TC2J6500 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB SX520A19F SX520A20F SX520A20F SX520A20P SX520A20P SX520A20R SX520A20R SX520A24F SX520A24F SX520A24P 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 14-6 SX530A14R SX530A19F SX530A20F SX530A20P SX530A20R SX530A24F SX530A24P SX530A24R SX530A29F SX530A30F 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 14-7 SX540C14P SX540C14R SX540C19F SX540C20F SX540C20P SX540C20R SX540C24F SX540C24P SX540C24R SX540C29F 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 14-10 TA1JG750 TA1JG750 TA1L6750 TA1L6750 TA1L6750 TA1L6750 TA1L6750 TA1Q1 TA1Q1 TA1Q300 MCCB 6-135 MCCB 6-135 MCCB 6-40 MCCB 6-42 MCCB 6-42 MCCB 6-44 MCCB 6-83 MCCB 6-27 MCCB 6-81 MCCB 6-82 TC2J6500 TC2JG250 TC2JG250 TC2K500 TC2K500 TC2K500 TC2K500 TC2K500 TC3K350 TC3K350 19-22 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 14-12 14-14 14-15 14-12 14-12 14-12 14-12 BUSW 14-12 BUSW 14-12 14-12 BUSW BUSW BUSW BUSW MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-120 6-135 6-59 6-62 6-83 6-120 6-135 6-59 6-59 6-59 6-104 6-135 6-27 6-30 6-81 6-81 6-83 6-40 6-42 6-44 6-83 6-104 6-135 4-22 6-51 6-53 6-55 6-83 4-22 6-51 Product Index Catalog Number Product Category Page TC3K350 TC3K350 TC3K350 TC3MG500 TC3MG500 TC3NG500 TC5R600 TC5R600 TC5R600 TC5R600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-53 6-55 6-83 6-112 6-135 6-135 6-120 6-135 6-59 6-60 TC5R600 TC5R600 TC5R600 TC5R600 TC5R600 TCE2 TCE3 TCF2 TCF3 TCJ2 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB TCJ3 TCL2 TCL3 TCM2 TCM3 TCN2 TCN3 TCW1FG350 TD010 TD010R MCCB MCCB MCCB MCCB MCCB MCCB MCCB TD210 TD210R TD210RS TD310 TD310R TD310RS TD410 TD410R TD410RS TD63S2000 BUSW 14-60 BUSW 14-60 14-60 BUSW 14-60 BUSW 14-60 14-60 BUSW 14-62 BUSW 14-62 14-62 6-72 TD63S2500 TD63S3200 TDF3 TDF4 TDH3 TDH4 TFAK32 TFAK32 TFAK32 TFAK35 Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page U01ED62AB U01ED62B U01FD60 U01JLD6 U01JLD6 U01JLD6 U01JLD6 U01JLD62A U01JLD62A U01JLD62A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-36 6-36 6-39 6-43 6-43 6-47 6-50 6-43 6-47 6-50 U06JLD64AA U06JLD64AA U06MN6 U06MN6 U06MN6 U06MN6 U07MN6 U07MN6 U07MN6 U07MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-47 6-50 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 U14JLD6 U14JLD6 U14JLD62A U14JLD62A U14JLD62A U14JLD62AA U14JLD62AA U14JLD62AA U15MN6 U15MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-47 6-50 6-43 6-47 6-50 6-43 6-47 6-50 6-58 6-61 6-62 6-62 6-62 6-62 6-83 6-91 6-91 6-91 6-91 6-91 TLK34Q TLK35Q TLK36Q TLK37Q TLK38Q TLK39Q TMK606 TMK606 TMK610 TMK610C XFMR XFMR XFMR XFMR XFMR XFMR HDSS HDSS HDSS HDSS 7-19 7-19 7-19 7-19 7-19 7-19 4-11 4-11 4-11 4-11 U01JLD62AA U01JLD62AA U01JLD62AA U01MN6 U01MN6 U01MN6 U01MN6 U01MN64A U01MN64A U01MN64A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-43 6-47 6-50 6-54 6-58 6-61 6-63 6-54 6-58 6-61 U07MN64A U07MN64A U07MN64A U07MN64A U07MN64AA U07MN64AA U07MN64AA U07MN64AA U08FD60 U08JLD6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-43 U15MN6 U15MN64A U15MN64A U15MN64A U15MN64A U15MN64AA U15MN64AA U15MN64AA U15MN64AA U16FD60 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-63 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-91 6-91 6-91 6-91 6-91 6-91 6-91 6-134 14-60 14-60 TMK620 TMK620C TMKJ TMKJ3 TNKD TNKD3 TNKE3 TNKE3 TNKE4 TNKF HDSS 4-11 HDSS 4-11 MCCB 6-135 6-135 MCCB 6-134 MCCB 6-134 MCCB 6-32 MCCB 6-81 6-81 MCCB 6-134 U01MN64A U01MN64AA U01MN64AA U01MN64AA U01MN64AA U02FD60 U02JLD6 U02JLD6 U02JLD62A U02JLD62A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-63 6-54 6-58 6-61 6-63 6-39 6-47 6-50 6-43 6-47 U08JLD6 U08JLD6 U09MN6 U09MN6 U09MN6 U09MN6 U09MN64A U09MN64A U09MN64A U09MN64A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-47 6-50 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 U16JLD6 U16JLD6 U16JLD62AA U16JLD62AA U16JLD62AA U16JLD64A U16JLD64A U16JLD64A UE145 UE145 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-47 6-50 6-43 6-47 6-50 6-43 6-47 6-50 14-53 14-53 TNKF3 TNKG3 TNKG3 TNKL TNKL3 TNKM TNKM3 TNKP TNKP TNKP3 MCCB 6-134 MCCB 6-30 MCCB 6-81 MCCB 6-135 MCCB 6-135 6-135 MCCB 6-135 MCCB 6-135 MCCB 6-135 MCCB 6-135 U02JLD62A U02JLD62AA U02JLD62AA U02JLD62AA U02MN6 U02MN6 U02MN6 U02MN6 U02MN64A U02MN64A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-50 6-43 6-47 6-50 6-54 6-58 6-61 6-63 6-54 6-58 U09MN64AA U09MN64AA U09MN64AA U09MN64AA U10FD60 U10JLD6 U10JLD6 U10JLD6 U10JLD62A U10JLD62A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-39 6-43 6-47 6-50 6-43 6-47 UE145 UE145 UE145 UE145 UE145 UE145 UE145 UE145 UE145 UE145 14-53 14-53 14-53 14-53 14-53 14-55 14-55 14-55 14-55 14-55 BUSW BUSW BUSW BUSW HDSS HDSS HDSS HDSS 6-72 6-72 14-60 14-62 14-60 14-62 14-57 14-57 4-21 14-57 TNKP3 TPSA9040 TPSASA1 TPSCOAX TPSESA3 TPSTEL TPTH TR1311 TR1312 TR3311 MCCB 6-135 RESI 1-33 RESI 1-33 RESI 1-34 RESI 1-33 RESI 1-34 BPLU 14-61 14-61 BUSW 14-61 BUSW 14-61 U02MN64A U02MN64A U02MN64AA U02MN64AA U02MN64AA U02MN64AA U03FD60 U03JLD6 U03JLD6 U03JLD6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-43 6-43 6-47 U10JLD62A U10JLD62AA U10JLD62AA U10JLD62AA U11MN6 U11MN6 U11MN6 U11MN6 U11MN64A U11MN64A MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-50 6-43 6-47 6-50 6-54 6-58 6-61 6-63 6-54 6-58 UE145 UE145 UE145 UE145 UE145 UE145 UE145 UE155 UE155 UE155 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-53 14-53 14-53 TFAK35 TFAK35 TFAK42 TFAK42 TFAK42 TFAK45 TFAK45 TFAK45 TFAK52 TFAK52 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 14-57 4-21 14-57 14-57 4-21 14-57 14-57 4-21 12-23 14-57 TR3312 TRB23 TRB23 TRH31 TRH31 TS31 TS31CABLE TSCFTM TSCFTM TSCLTM BUSW BUSW BUSW BUSW BUSW MCCB MCCB MCCB MCCB MCCB 14-61 14-60 14-62 14-60 14-62 6-79 6-79 6-136 6-136 6-137 U03JLD6 U03JLD62A U03JLD62A U03JLD62A U03JLD62AA U03JLD62AA U03JLD62AA U03MN6 U03MN6 U03MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-50 6-43 6-47 6-50 6-43 6-47 6-50 6-54 6-54 6-58 U11MN64A U11MN64A U11MN64AA U11MN64AA U11MN64AA U11MN64AA U12FD60 U12JLD6 U12JLD6 U12JLD6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-43 6-47 6-50 UE155 UE155 UE155 UE155 UE155 UE155 UE155 UE175 UE175 UE175 14-53 14-53 14-53 14-55 14-55 14-55 14-55 14-53 14-53 14-53 TFAK52 TFAK52 TFAK55 TFAK55 TFAK55 TFAK55 TFAK62 TFAK62 TFAK62 TFAK62 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 14-57 4-21 12-23 14-57 14-57 4-21 12-23 14-57 14-57 4-21 TSCLTM TSCMTM TSCPET TSCPET TSCPET TSCPET TSCPET TSCPET TSCPET TSLF3 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-137 6-137 6-136 6-136 6-137 6-137 6-137 6-137 6-137 6-132 U03MN6 U03MN6 U03MN64A U03MN64A U03MN64A U03MN64A U03MN64AA U03MN64AA U03MN64AA U03MN64AA MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-61 6-63 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 U12JLD62A U12JLD62A U12JLD62A U12JLD62AA U12JLD62AA U12JLD62AA U13FD60 U13JLD6 U13JLD6 U13JLD6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-43 6-47 6-50 6-43 6-47 6-50 6-39 6-43 6-47 6-50 UE175 UE175 UE175 UE195 UE195 UE195 UE195 UE275 UE275 UE275 14-53 14-53 14-55 14-53 14-55 14-55 14-55 14-53 14-53 14-55 TFAK65 TFAK65 TFAK65 TFAK65 TFAK72 TFAK72 TFAK75 TFAK75 TFAK75 TFAK82 HDSS 12-23 HDSS 14-57 HDSS 14-57 HDSS 4-21 HDSS 3-17 HDSS 4-22 HDSS 3-17 HDSS 4-21 HDSS 4-22 HDSS 3-17 TSLF3 TSLL3 TSLL3 TSLM3 TSLP3 TSLP3 TSSF3 TSSF3 TSSG3A TSSL3 MCCB 6-132 6-133 6-133 6-133 MCCB 6-133 MCCB 6-133 6-132 6-132 6-86 6-133 U04MN6 U04MN6 U04MN6 U04MN6 U04MN64A U04MN64A U04MN64A U04MN64A U04MN64AA U04MN64AA MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 6-54 6-58 U13JLD62A U13JLD62A U13JLD62A U13JLD62AA U13JLD62AA U13JLD62AA U13MN6 U13MN6 U13MN6 U13MN6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-43 6-47 6-50 6-43 6-47 6-50 6-54 6-58 6-61 6-63 UE275 UE295 UE295 UE295 UE295 UE295 UE295 UE295 UE295 UE295 14-55 14-53 14-53 14-53 14-53 14-55 14-55 14-55 14-55 14-55 TFAK82 TFP223 TFP224 TFP323 TFP324 TFP363 TFP364 THEL THEL THEM HDSS HDSS HDSS HDSS HDSS HDSS HDSS TSSL3 TSSM3 TSSP3 TSSP3 TW1DG20 TW1FG350 TW1JG600 U01ED60 U01ED62A U01ED62AA 6-133 6-133 MCCB 6-133 MCCB 6-133 MCCB 6-134 6-134 6-135 MCCB 6-36 MCCB 6-36 MCCB 6-36 U04MN64AA U04MN64AA U06FD60 U06JLD6 U06JLD6 U06JLD6 U06JLD64A U06JLD64A U06JLD64A U06JLD64AA MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-61 6-63 6-39 6-43 6-47 6-50 6-43 6-47 6-50 6-43 U13MN64A U13MN64A U13MN64A U13MN64A U13MN64AA U13MN64AA U13MN64AA U13MN64AA U14FD60 U14JLD6 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-54 6-58 6-61 6-63 6-54 6-58 6-61 6-63 6-39 6-43 UE295 UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 14-55 14-53 14-53 14-53 14-53 14-53 14-53 14-53 14-53 14-53 4-22 4-24 4-24 4-24 4-24 4-24 4-24 6-139 6-139 MCCB 6-139 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-23 PRODUCT INDEX MCCB 6-139 MCCB 6-139 XFMR 7-19 XFMR 7-19 XFMR 7-19 XFMR 7-19 XFMR 7-19 XFMR 7-19 XFMR 7-19 XFMR 7-19 19 THEP THEP TLK11Q TLK12Q TLK13Q TLK14Q TLK15Q TLK31Q TLK32Q TLK33Q Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 14-53 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 UFS179 UFS179 UFS179 UFS279 UFS279 UFS279 UFS279 UFS279 UFS279 UFS279 14-55 14-55 14-55 14-53 14-53 14-53 14-53 14-53 14-53 14-55 UVREE250D UVREM60 UVREM60 UVREN120 UVREN120 UVRER240 UVRER240 UVREU480 UVREU480 UVREV600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 UF145 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 UFS279 UFS279 UFS279 UFS279 UFS279 UFS279 UFS279 UH145 UH145 UH145 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-53 14-53 14-53 UVREV600 UVRLA12DC UVRLA12DC UVRLA12DC UVRLA12DC UVRLB24DC UVRLB24DC UVRLB24DC UVRLB24DC UVRLC48DC UF145 UF155 UF155 UF155 UF155 UF155 UF155 UF155 UF155 UF155 14-55 14-53 14-53 14-53 14-53 14-55 14-55 14-55 14-55 14-55 UH145 UH145 UH145 UH145 UH145 UH145 UH145 UH145 UH145 UH145 14-53 14-53 14-53 14-53 14-55 14-55 14-55 14-55 14-55 14-55 UF175 UF175 UF175 UF175 UF175 UF195 UF195 UF195 UF195 UF275 14-53 14-53 14-53 14-53 14-55 14-53 14-53 14-55 14-55 14-53 UH145 UH145 UH145 UH145 UH145 UH145 UH155 UH155 UH155 UH155 UF275 UF275 UF275 UF275 UF275 UF295 UF295 UF295 UF295 UF295 14-53 14-55 14-55 14-55 14-55 14-53 14-53 14-53 14-53 14-55 UF295 UF295 UF295 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 Catalog Number Product Category Page Catalog Number Product Category Page 6-33 6-25 6-33 6-25 6-33 6-25 6-33 6-25 6-33 6-25 UVRPS277 UVRPS277 UVRPS277 UVRPT415 UVRPT415 UVRPT415 UVRPU480 UVRPU480 UVRPU480 UVRPV600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-33 6-103 6-107 6-111 6-99 6-103 6-107 6-111 6-99 MCCB 6-103 UVRPV600 UVRPV600 UX001WL UX005B V2A2211LR V2A3211 V2B2211LR V2B2212LR V2B2222LR V2B3211 MCCB 6-119 MCCB 6-122 2-85 RESG 2-85 VBSS 4-18 VBSS 4-18 VBSS 4-18 VBSS 4-18 VBSS 4-18 VBSS 4-18 VB357BL VB358BL VB610 VB6150 VB6150 VB6150 VB657 VB657 VB657 VB657 VBSS 4-20 VBSS 4-20 SWBD 12-26 SWBD 12-26 SWBD 4-21 SWBD 4-21 SWBD 12-26 SWBD 4-21 SWBD 4-21 SWBD 4-21 UVRLC48DC UVRLC48DC UVRLC48DC UVRLD125DC UVRLD125DC UVRLD125DC UVRLD125DC UVRLE250 UVRLE250DC UVRLE250DC MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-107 6-111 6-99 6-103 6-107 6-111 6-99 6-103 MCCB 6-107 MCCB 6-111 V2B3211R V2B3212 V2B3212R V2B3222 V2B3222R V2E2203LR V2E2204LR V2E3203 V2F3204 V2F3204MS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS 4-18 4-18 4-18 4-18 4-18 4-18 4-18 4-18 4-18 4-18 VB657 VB657 VB657 VB671 VB671 VB7F025 VB7F050 VB7F075 VBFS321 VBFS321F SWBD 4-21 SWBD 4-21 SWBD 4-21 SWBD 12-26 SWBD 4-21 10-73 10-73 10-73 HDSS 4-7 HDSS 4-7 14-55 14-55 14-55 14-55 14-55 14-55 14-53 14-53 14-53 14-53 UVRLE250DC UVRLG60DC UVRLG60DC UVRLG60DC UVRLG60DC UVRLN120 UVRLN120 UVRLN120 UVRLN120 UVRLP208 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-99 6-103 6-107 6-111 6-99 6-103 6-107 6-111 6-99 6-103 V7A2211__ V7A3211 V7B2211__ V7B2211__R V7B2212LR V7B2212LRR V7B2222__ V7B2222__R V7B3211 V7B3211R 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-19 VBFS322 VBFS322F VBFS361 VBFS361F VBFS362 VBFS362F VBFS363 VBFS363F VBFS364 VBFS364F HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 UH155 UH155 UH155 UH155 UH155 UH155 UH175 UH175 UH175 UH175 14-53 14-53 14-55 14-55 14-55 14-55 14-53 14-53 14-53 14-53 UVRLP208 UVRLP208 UVRLP208 UVRLR240 UVRLR240 UVRLR240 UVRLR240 UVRLS277 UVRLS277 UVRLS277 MCCB 6-107 MCCB 6-111 MCCB 6-99 6-103 6-107 6-111 6-99 MCCB 6-103 MCCB 6-107 MCCB 6-111 V7B3212 V7B3212R V7B3222 V7B3222R V7E2203LR V7E2204__ V7E2204MS V7E2223LR V7E2233__ V7E2603LR VBSS VBSS VBSS VBSS VBSS 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-20 VBFS365 VBFS366 VBH1 VBH14X VBH2 VBHM1 VBLK1 VBLK2 VBLK3 VBLK4 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 14-55 14-55 14-55 14-53 14-53 14-53 14-53 14-53 14-53 14-53 UH175 UH175 UH195 UH195 UH195 UH195 UH275 UH275 UH275 UH275 14-55 14-55 14-53 14-53 14-55 14-55 14-53 14-53 14-55 14-55 UVRLS277 UVRLT415 UVRLT415 UVRLT415 UVRLT415 UVRLU480 UVRLU480 UVRLU480 UVRLU480 UVRLV600 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-99 6-103 6-107 6-111 6-99 6-103 6-107 6-111 6-99 6-103 V7E2611LR V7E2612LR V7E2622LR V7E3202 V7E3203 V7E3203MS V7E3223 V7E3233 V7E3233R V7E3601 VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS 4-20 4-20 4-20 4-19 4-19 4-19 4-19 4-19 4-19 4-20 VBNFS361 VBNFS361F VBNFS362 VBNFS362F VBNFS363 VBNFS363F VBNFS364 VBNFS364F VBNFS365 VBNFS366 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 4-7 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 14-53 14-53 14-53 14-53 14-53 14-53 14-53 14-55 14-55 14-55 UH275 UH275 UH295 UH295 UH295 UH295 UH295 UH295 UH295 UH295 14-55 14-55 14-53 14-53 14-53 14-53 14-55 14-55 14-55 14-55 UVRLV600 UVRLV600 UVRLV600 UVRPA12DC UVRPA12DC UVRPA12DC UVRPB24DC UVRPB24DC UVRPB24DC UVRPC48DC MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-107 6-111 6-99 6-115 6-119 6-122 6-115 6-119 6-122 6-115 V7E3602 V7E3603 V7E3603MS V7E3611 V7E3611R V7E3612 V7E3622 V7E3622R V7E3623 V7E3633 VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS 4-20 4-20 4-20 4-20 4-20 4-20 4-20 4-20 4-20 4-20 VBWK1 VBWK2 VBWK3 VF357TL VF358TL VH9499 VMS325B VMS325T VMS326B VMS326T HDSS HDSS HDSS VBSS VBSS MCCB VBSS VBSS VBSS VBSS 4-8 4-8 4-8 4-20 4-20 6-88 4-19 4-19 4-19 4-19 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 UFS145 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 14-55 UJ100 UK1000TA UK350TA UK600TA UPAPELTK UPAPELTK UPAPELTK UPAPELTK UPAPELTK UPAPELTK BUSW 14-51 RESG 2-26 RESG 2-26 RESG 2-26 6-138 6-138 6-139 6-139 6-139 6-139 UVRPC48DC UVRPC48DC UVRPD125DC UVRPD125DC UVRPD125DC UVRPE250DC UVRPE250DC UVRPE250DC UVRPG60DC UVRPG60DC MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-119 6-122 6-115 6-119 6-122 6-115 6-119 6-122 6-115 6-119 V7E3633R V7F2604LR V7F3204 V7F3204MS V7F3244R V7F3604 V7F3604MS V7F3604R V7F3644 V7F3644J VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS 4-20 4-20 4-19 4-19 4-19 4-20 4-20 4-20 4-19 4-20 VMS365B VMS365T VMS366B VMS366T W01FD64 W0202MB1100CU W0202MB1200CU W0202ML1200CU W0204ML1060 W0204ML1060 VBSS VBSS VBSS VBSS MCCB RESI RESI RESI RESI RESI 4-20 4-20 4-20 4-20 6-39 1-10 1-10 1-10 1-10 5-10 UFS145 UFS145 UFS145 UFS179 UFS179 UFS179 UFS179 UFS179 UFS179 UFS179 14-55 14-55 14-55 14-53 14-53 14-53 14-53 14-53 14-53 14-55 UPAPELTK UPGR314G UVREA12AD UVREB24AD UVREB24AD UVREC48D UVREC48D UVRED125D UVRED125D UVREE250D 6-139 BPLU 14-58 6-25 MCCB 6-25 MCCB 6-33 MCCB 6-25 MCCB 6-33 MCCB 6-25 MCCB 6-33 MCCB 6-25 UVRPG60DC UVRPN120 UVRPN120 UVRPN120 UVRPP208 UVRPP208 UVRPP208 UVRPR240 UVRPR240 UVRPR240 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-122 6-115 6-119 6-122 6-115 6-119 6-122 6-115 6-119 6-122 V7H2205LR V7H2205MS V7H2206LR V7H2206MS V7H2605MR V7H3205 V7H3205750 V7H3205MS V7H3206 V7H3206MS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS VBSS 4-19 4-19 4-19 4-19 4-20 4-19 4-19 4-19 4-19 4-19 W0204ML1125CU W02FD64 W0303ML3100 W0303ML3100 W03FD64 W0404MB1200CT W0404MB1200CT W0406ML1225CU W0406ML1225CU W0406ML1225CU RESI MCCB RESI RESI MCCB RESI RESI RESI RESI RESI 1-10 6-39 1-10 5-10 6-39 1-13 1-9 1-10 1-9 5-10 19-24 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog VBSS VBSS VBSS VBSS VBSS VBSS VBSS 6-115 6-119 6-122 6-115 6-119 6-122 6-115 6-119 6-122 6-115 V7H3605 V7H3605750 V7H3605MS V7H3606 V7H3606MS VB2F025 VB2F050 VB2F075 VB2F100 VB2F100 VBSS VBSS VBSS VBSS VBSS 4-20 4-20 4-20 4-20 4-20 10-73 10-73 10-73 10-73 10-73 Product Index Catalog Number Product Category Page Catalog Number W0408L1125SPA50 W0408L1125SPA50 W0408L1125SPA60 W0408L1125SPA60 W0408ML1125 W0606ML1400CU W06FD64 W0816B1200CT W0816B1200CT W0816L1200CT RESI RESI RESI RESI RESI RESI MCCB RESI RESI RESI 1-13 1-9 1-13 1-9 1-9 1-12 6-39 1-13 1-7 1-13 W4040L1200CU W410190 W411239 W411239 W411239 W411239 W411239 W411239 W4242B1225CU W4242B3200CU W0816L1200CT W0816ML1125CU W10FD64 W1212L1125CU W1224B10060GC W1224B1100CU W1224L1125CU W1224L1200CU W1224L1225CU W1224L3125CU RESI RESI MCCB RESI RESI RESI RESI RESI RESI RESI 1-7 1-9 6-39 1-7 1-13 1-7 1-7 1-7 1-7 1-11 W1224L3200CU W12FD64 W13FD64 W14FD64 W1624B1100CU W1624L1125CU W16FD64 W1836L3150CU W1MM1225U W1MM1225USS RESI MCCB MCCB MCCB RESI RESI MCCB RESI RESG RESG W1MM1400 W1MM1400B W1MM2225U W1MM2225USS W1MM2400 W1MM3225U W1MM3225USS W1MM4225U W2020B1100CU W2030L1150CU Product Category Page Product Category Page Catalog Number Product Category Page SWBD HDSS HDSS SWBD SWBD SWBD SWBD SWBD SWBD HDSS 14-57 14-57 14-57 14-57 14-57 4-21 14-57 14-57 4-21 5-11 WMC12 WMC124 WMC124BF WMC12BF WMC14 WMC144 WMC144BF WMC14BF WMC16 WMC164 RESG RESG RESG RESG RESG RESG W4242B3225CU W4242L1225CU W4242L3225CU W4242MB1400CU W4242MB3400CU W4242ML1400CU W4242ML3400CU W43000 W43002 W43099 1-11 1-7 1-11 1-12 1-12 1-12 1-12 4-21 4-21 BPLU 14-60 W60992 W60992 W60992 W60992 W60992 W60992 W60992 W60993 W60993 W60993 HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS 5-13 5-4 5-7 5-7 5-7 5-9 6-41 5-11 5-12 5-13 1-11 6-39 6-39 6-39 1-7 1-7 6-39 1-11 2-47 2-51 W43099 W43100 W43100 W43101 W43101 W43771 W43771 W47185 W47185 W48762 BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU 14-62 14-60 14-62 14-60 14-62 14-60 14-62 14-56 14-58 4-21 W60993 W60993 W60993 W60993 W60993 W60993 W62890 W62891 W63231 W63232 HDSS HDSS HDSS HDSS HDSS HDSS BPLU BPLU BPLU BPLU RESG RESG RESG RESG RESG RESG RESG RESG RESI RESI 2-47 2-50 2-47 2-51 2-47 2-47 2-51 2-47 1-7 1-7 W48763 W48764 W48765 W49813 W49813 W49813 W49813 W49813 W49814 W49814 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD 4-21 4-21 4-21 12-23 14-57 14-57 14-57 4-21 12-23 14-57 W63233 W63234 W63234 W63238 W63238 W63553 W63554 W63623 W63623 W63623 BPLU BPLU BPLU BPLU BPLU BPLU BPLU HDSS HDSS HDSS W2040B1200CU W2040L1200CU W2424L1125CU W2442B3150CU W2442L3150CU W2442L3200CU W2MM1225U W2MM1225USS W2MM1400AB W2MM1400BAB RESI RESI RESI RESI RESI RESI RESG RESG RESG RESG 1-7 1-7 1-7 1-11 1-11 1-11 2-48 2-51 2-48 2-50 W49814 W49815 W49815 W49815 W49816 W49816 W49816 W49818 W49818 W49819 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD 4-21 12-23 14-57 4-21 12-23 14-57 4-21 14-57 4-21 14-57 W63623 W63623 W63623 W63623 W63623 W63623 W63623 W63623 W63623 W63810 W2MM2400AB W2MM2AB225U W2MM2AB225USS W2MM2BC225U W2MM2BC225USS W2MM2CA225U W2MM2CA225USS W2MM3225U W2MM3225USS W2MM4AB225U RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-48 2-48 2-51 2-48 2-51 2-48 2-51 2-48 2-51 2-48 W49819 W49827 W49827 W49828 W49828 W49829 W49830 W49830 W49832 W49832 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD 4-21 14-57 4-21 14-57 4-21 4-21 14-57 4-21 14-57 4-21 W68101 W68113 W73534 WB2150B WB2200B WB2225 WB2225 WB2225 WB3100 WB3100 W2MM4BC225U W2MM4CA225U W3030MB1400CU W3030ML1400CU W3040B1200CP W3040B1200CU W3040L1125CU W3040L1200CP W3040L1200CU W3042B3200CU RESG RESG RESI RESI RESI RESI RESI RESI RESI RESI 2-48 2-48 1-12 1-12 1-8 1-7 1-7 1-8 1-7 1-11 W53045 W53045 W53045 W53045 W55365 W55365 W55365 W55365 W55365 W55365 HDSS HDSS HDSS HDSS SWBD SWBD SWBD SWBD SWBD SWBD 5-11 5-12 5-13 5-9 14-57 14-57 14-57 14-57 4-21 4-21 WB3100 WB3225 WB3225 WB3225 WBMEFM WBMFDP WBMFDP WBMFFM WBMFFM WBMLDP W3042L3200CU W37940 W37940 W3MM1 W3MM1200U W3MM1225USS W3MM1400 W3MM1400B W3MM2 W3MM2200U RESI 1-11 BPLU 14-57 BPLU 14-58 RESG 2-49 RESG 2-49 RESG 2-51 RESG 2-49 RESG 2-50 RESG 2-49 RESG 2-49 W55366 W55366 W55366 W55366 W55366 W55366 W55367 W55367 W55367 W55367 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD 14-57 14-57 14-57 14-57 4-21 4-21 14-57 14-57 14-57 14-57 W3MM2225USS W3MM2400 W3MM3 W3MM3200U W3MM3225USS W3MM4 W3MM4200U W4040B1200CP W4040B1200CU W4040L1200CP RESG W55367 W55367 W55368 W55368 W55368 W55368 W55368 W55368 W56623 W56626 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD 4-21 4-21 14-57 14-57 14-57 14-57 4-21 4-21 4-21 14-57 2-51 2-49 2-49 2-49 2-51 2-49 2-49 1-8 1-7 1-8 RESI RESI RESI RESI RESI RESI RESI Product Category Page RESG RESG RESG 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-41 WMM5URNJ WMM64U WMM64UR WMM64URNJ WMM6U WMM6UR WMM6URNJ WMMB11200 WMMB1400 WMMB1800 RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-45 2-44 2-45 2-45 2-44 2-45 2-45 2-43 2-43 2-43 WMC164BF WMC16BF WMC4 WMC44 WMC44BF WMC4BF WMC6 WMC64 WMC64BF WMC6BF RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-41 WMMB31200 WMMB3400 WMMB3800 WMMBK WMP024U WMP02U WMS124U WMS12U WMS44U WMS44UPBU RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-43 2-43 2-43 2-81 2-42 2-42 2-42 2-42 2-42 2-42 5-5 5-7 5-7 5-9 5-9 6-45 14-56 14-56 14-57 14-57 WMC7 WMC74 WMC74BF WMC7BF WMC8 WMC84 WMC84BF WMC8BF WMEP WMEX1U RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-41 2-81 2-81 WMS4U WMS4UPBU WMS64U WMS64UPBU WMS6U WMS6UPBU WMS84U WMS84UPBU WMS8U WMS8UPBU RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-42 2-42 2-42 2-42 2-42 2-42 2-42 2-42 2-42 2-42 14-57 14-57 14-57 14-57 14-57 14-57 14-57 5-11 5-13 5-5 WMEX4U WMM2200U WMM2200UR WMM22URNJ WMM24AB200U WMM24AB2URNJ WMM2U WMM2UR WMM2URNJ WMM3200U RESG RESG RESG RESI RESG RESI RESG RESG RESG RESG 2-81 2-44 2-45 2-45 2-44 2-45 2-44 2-45 2-45 2-44 WMTB124U WMTB12U WMTB164U WMTB16U WMTB84U WMTB8U WN2060 WN2060GFCI WN2060PL WN2060PLX RESG RESG RESG RESG RESG RESG RESI RESI RESI RESI 2-43 2-43 2-43 2-43 2-43 2-43 1-15 1-15 1-15 1-15 HDSS 5-6 HDSS 5-7 HDSS 5-7 HDSS 5-9 HDSS 5-9 HDSS 6-49 HDSS 6-51 HDSS 6-53 HDSS 6-55 BPLU 14-56 WMM3200UR WMM32URNJ WMM34200U WMM34200UR WMM342URNJ WMM34U WMM34UR WMM34URNJ WMM3U WMM3UR RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-45 2-45 2-44 2-45 2-45 2-44 2-45 2-45 2-44 2-45 WNAS2060 WNAS2060GFCI WNAS2060PL WP32 WP32 WP32 WP32 WP32 WP32 WP38 RESI RESI UNPB UNPB UNPB UNPB UNPB UNPB UNPB 1-15 1-15 1-15 10-10 10-10 10-10 10-10 10-10 10-10 10-10 BPLU 14-56 BPLU 14-49 BPLU 14-57 RESI 1-10 RESI 1-10 RESI 1-10 RESI 5-11 RESI 6-28 RESI 1-10 RESI 5-10 WMM3URNJ WMM4200U WMM4200UR WMM42URNJ WMM44AB200U WMM44AB200UR WMM44AB2URNJ WMM44ABU WMM44ABUR WMM44ABURNJ RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-45 2-44 2-45 2-45 2-44 2-45 2-45 2-44 2-45 2-45 WP38 WP38 WP38 WP38 WP38 WP44 WP44 WP44 WP44 WP44 UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 6-27 1-10 5-11 6-28 6-87 6-136 6-136 6-136 6-136 6-137 WMM44BC200U WMM44BC200UR WMM44BC2URNJ WMM44BCU WMM44BCUR WMM44BCURNJ WMM44CA200U WMM44CA200UR WMM44CA2URNJ WMM44CAU RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-44 2-45 2-45 2-44 2-45 2-45 2-44 2-45 2-45 2-44 WP44 WP56 WP56 WP56 WP56 WP56 WP56 WP62 WP62 WP62 UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 WBMLDP WBMLFM WBMLFM WBMMDP WBMMFM WBMPDP WBMPDP WBMPFM WBMPFM WF1 6-137 6-137 6-137 6-137 6-137 6-137 6-137 6-137 6-137 BPLU 14-49 WMM44CAUR WMM44CAURNJ WMM4U WMM4UR WMM4URNJ WMM54AB200U WMM54AB2URNJ WMM54ABU WMM54ABUR WMM54ABURNJ RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-45 2-45 2-44 2-45 2-45 2-44 2-45 2-44 2-45 2-45 WP62 WP62 WP62 WP68 WP68 WP68 WP68 WP68 WP68 WPB224 UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB UNPB SWBD 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 10-10 12-20 WF2030 WF2030GFCI WF2030PL WF2060 WF2060GFCI WF2060PL WMC10 WMC104 WMC104BF WMC10BF RESI RESI RESI RESI RESI RESI RESG RESG RESG RESG WMM54BC200U WMM54BC2URNJ WMM54BCUR WMM54BCURNJ WMM54CA200U WMM54CA2URNJ WMM54CAUR WMM54CAURNJ WMM5U WMM5UR RESG RESG RESG RESG RESG RESG RESG RESG RESG RESG 2-44 2-45 2-45 2-45 2-44 2-45 2-45 2-45 2-44 2-45 WPB226 WPB228 WPB424 WPB426 WPB428 WPB444 WPB446 WPB448 WPF224 WPF226 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD 12-20 12-20 12-20 12-20 12-20 12-20 12-20 12-20 12-21 12-21 RESI RESI RESI RESI 1-15 1-15 1-15 1-15 1-15 1-15 2-41 2-41 2-41 2-41 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog 19-25 PRODUCT INDEX W56626 W56627 W56627 W56628 W56628 W56628 W56629 W56629 W56629 W60992 Catalog Number 19 1-7 3-17 5-11 5-13 5-5 5-6 5-7 5-9 1-7 1-11 RESG RESG RESG RESG RESG RESI RESI RESI RESI HDSS HDSS HDSS HDSS HDSS HDSS HDSS RESI RESI Catalog Number Product Index PRODUCT INDEX 19 Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number Product Category Page Catalog Number WPF424 WPF426 WPF444 WPF446 WPUG14 WPUG26 WSC150C WSC250C WSC350C WSN251CR SWBD SWBD SWBD SWBD SWBD SWBD RESG RESG RESG RESG 12-21 12-21 12-21 12-21 12-23 12-23 2-6 2-6 2-6 2-6 X4003ETVB X4003ETVBG X4003ETVBGIG X4003ETVBIG X4003FE X4003FEG X4003FEGIG X4003FEIG X4003G X4003GIG 14-49 14-49 14-49 14-49 14-48 14-48 14-48 14-48 14-48 14-48 XC1004IG XC1004L XC1004LG XC1004LGIG XC1004LIG XE100 XE100 XE100 XE100 XE100 BUSW 14-48 14-49 14-49 14-49 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 37 37 37 40 40 42 42 43 45 45 WSN351CR WSN451CR WSX019 X103PB X103PBG X103PBGIG X103PBIG X104PB X104PBG X104PBGIG RESG RESG BUSW BUSW BUSW BUSW 2-6 2-6 2-10 14-49 14-49 14-49 14-49 14-49 14-49 14-49 X4003IG X4003L X4003LG X4003LGIG X4003LIG X4003M X4003MG X4003MGIG X4003MIG X4004 14-48 14-49 14-49 14-49 14-49 14-49 14-49 14-49 14-49 14-48 XE100 XE100 XE100 XE200 XE200 XE200 XE200 XE200 XE200 XE200 BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW 14-49 14-49 14-49 14-49 14-49 14-49 14-49 14-49 14-49 14-49 48 48 49 49 49 49 49 49 49 49 X104PBIG X2003 X20032 X20032G X20032GIG X20032IG X20035 X20035G X20035GIG X20035IG BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW 14-49 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 X40042 X40042G X40042GIG X40042IG X40045 X40045G X40045GIG X40045IG X4004ETVB X4004ETVBG 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-49 14-49 XE200 XE400 XE400 XE400 XE400 XE400 XE400 XE400 XE400 XEC3100 BUSW 14-49 14-49 14-49 14-49 14-49 14-49 14-49 14-49 14-49 BPLU 14-56 49 49 49 49 49 49 49 49 75 75 X2003ETVB X2003ETVBG X2003ETVBGIG X2003ETVBIG X2003FE X2003FEG X2003FEGIG X2003FEIG X2003G X2003GIG BUSW BUSW BUSW BUSW BUSW BUSW 14-49 14-49 14-49 14-49 14-48 14-48 14-48 14-48 14-48 14-48 X4004ETVBGIG X4004ETVBIG X4004FE X4004FEG X4004FEGIG X4004FEIG X4004G X4004GIG X4004IG X4004L 14-49 14-49 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-49 XEC3100IG XEC4100 XEC4100IG XEQH XH2 XLEC3100 XLEC4100 XLVB321 XLVB322 XLVB323 BPLU BPLU BPLU BPLU BUSW BPLU BPLU BPLU BPLU BPLU 14-56 14-56 14-56 14-56 14-48 14-56 14-56 14-56 14-56 14-56 X2003IG X2003L X2003LG X2003LGIG X2003LIG X2003M X2003MG X2003MGIG X2003MIG X2003PB BUSW 14-48 14-49 14-49 14-49 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 14-49 X4004LG X4004LGIG X4004LIG X4004M X4004MG X4004MGIG X4004MIG XC1003 XC10032 XC10032G 14-49 14-49 14-49 14-49 14-49 14-49 14-49 BUSW 14-48 BUSW 14-48 BUSW 14-48 XLVB351 XLVB352 XLVB353 XLVB421N XLVB422N XLVB423N XLVB451N XLVB452N XLVB453N XOC BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU BPLU X2003PBG X2004 X20042 X20042G X20042GIG X20042IG X20045 X20045G X20045GIG X20045IG BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW 14-49 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 XC10032GIG XC10032IG XC10035 XC10035G XC10035GIG XC10035IG XC1003ETVB XC1003ETVBG XC1003ETVBGIG XC1003ETVBIG BUSW BUSW BUSW BUSW BUSW BUSW 14-48 14-48 14-48 14-48 14-48 14-48 14-49 14-49 14-49 14-49 XQ35 XQ35R XQ45 XQ45R XQBRKCVR 11 14 14 14 17 BPLU BPLU BPLU BPLU X2004ETVB X2004ETVBG X2004ETVBGIG X2004ETVBIG X2004FE X2004FEG X2004FEGIG X2004FEIG X2004G X2004GIG BUSW BUSW BUSW BUSW BUSW BUSW 14-49 14-49 14-49 14-49 14-48 14-48 14-48 14-48 14-48 14-48 XC1003FE XC1003FEG XC1003FEGIG XC1003FEIG XC1003G XC1003GIG XC1003IG XC1003L XC1003LG XC1003LGIG BUSW BUSW BUSW BUSW BUSW BUSW BUSW 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-49 14-49 14-49 X2004IG X2004L X2004LG X2004LGIG X2004LIG X2004M X2004MG X2004MGIG X2004MIG X2004PB BUSW 14-48 14-49 14-49 14-49 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 BUSW 14-49 XC1003LIG XC1004 XC10042 XC10042G XC10042GIG XC10042IG XC10045 XC10045G XC10045GIG XC10045IG BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW BUSW X2004PBG X4003 X40032 X40032G X40032GIG X40032IG X40035 X40035G X40035GIG X40035IG BUSW 14-49 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 XC1004ETVB XC1004ETVBG XC1004ETVBGIG XC1004ETVBIG XC1004FE XC1004FEG XC1004FEGIG XC1004FEIG XC1004G XC1004GIG BUSW BUSW BUSW BUSW BUSW BUSW 19-26 BUSW BUSW Product Category Page Product Category Page 16-65 16-66 16-67 16-44 16-45 16-160 NEMA 16-161 NEMA 16-46 16-160 NEMA 16-161 1D1N007 1D1N007QST 1D1N010 1D1N010QST 1D1N015 1D1N015QST 1D1N105 1D1N105QST 1D1N110QST 1D1N115QST 16-157 16-48 16-156 16-157 16-158 16-81 16-82 16-83 16-84 16-85 1D1N205 1D1N205QST 1D1N505 1D1N505QST 1D1N555QST 1D1N705 1D1N705QST 1D1N775QST 1D1Y015TP1 1D1Y025TP1 NEMA NEMA NEMA IEC NEMA NEMA NEMA NEMA 16-86 16-87 16-88 16-80 16-90 16-91 16-92 16-93 16-156 16-157 1D1Y025TP1QST 1D1Y037TP1 1D1Y037TP1QST 1D1Y050TP1 1D1Y050TP1QST 1D1Y075TP1 1D1Y075TP1QST 1D1Y100TP1 1D1Y100TP1QST 1D1Y167TP1 7-18 7-6 7-18 7-6 7-18 7-6 7-18 7-6 7-18 7-6 75 75 83 83 83 83 84 84 84 84 NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA 16-86 16-87 16-52 16-53 16-54 16-55 16-52 16-53 16-54 16-55 1D1Y167TP1QST 1E1U003 1E1U005 1E1U007 1E1U010 1E1U015 1E1U025 1F1R003 1F1R005 1F1R007 7-18 7-6 7-6 7-6 7-6 7-6 7-6 7-6 7-6 7-6 14-56 14-56 14-56 14-56 14-56 14-56 14-56 14-56 14-56 14-48 87 87 87 88 88 97 97 97 958 050BB1224Q NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA XFMR 16-58 16-59 16-62 16-60 16-61 16-49 16-50 16-51 16-49 7-19 1F1R010 1F1R015 1F1R025 1G1R003 1G1R005 1G1R007 1G1R010 1G1R015 1G1R025 1G1Y025TP1 7-6 7-6 7-6 7-7 7-7 7-7 7-7 7-7 7-7 7-7 NEMA NEMA NEMA NEMA NEMA 14-56 14-56 14-56 14-56 14-56 16-10 16-14 16-15 16-16 16-17 050BB1632Q 050BB2448Q 100BB1224Q 100BB1632Q 100BB2448Q 105BB1224Q 105BB1632Q 105BB2448Q 11-1056-01 11-1824-01 UNPB 7-19 7-19 7-19 7-19 7-19 7-19 7-19 7-19 10-11 10-11 1G1Y037TP1 1G1Y050TP1 1G1Y075TP1 1G1Y100TP1 1G1Y167TP1 1H1N001 1H1N002 1H1N003 1H1N005 1H1N007 7-7 7-7 7-7 7-7 7-7 7-7 7-7 7-7 7-7 7-7 17 17 17 17 17 17 18 18 18 22 NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA 16-18 16-19 16-20 16-21 16-22 16-23 16-24 16-25 16-26 16-27 12-1110-01 12CLN500 12CLN500 150BB1224Q 150BB1632Q 150BB2448Q 1B1N001 1B1N002 1B1N003 1B1N005 10-11 6-116 6-135 XFMR 7-19 7-19 7-19 7-6 7-6 7-6 7-6 1H1N010 1H1N015 1H1N025 1H1N037 1H1N050 1H1N075 1H1N100 1H8N001 1H8N002 1H8N003 7-7 7-7 7-7 7-7 7-7 7-7 7-7 7-7 7-7 7-7 14-49 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 14-48 22 25 26 30 30 30 30 32 32 32 NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA 16-28 16-29 16-30 16-32 16-33 16-34 16-35 16-36 16-37 16-38 1B1N007 1B1N010 1B1N015 1B1Y025TP1 1B1Y037TP1 1B1Y050TP1 1B1Y075TP1 1B1Y100TP1 1B1Y167TP1 1BB1224Q 7-6 7-6 7-6 7-6 7-6 7-6 7-6 7-6 7-6 7-19 1H8N005 1H8N007 1LPC005 1LPC007 1LPC010 1LPC015 1LPC025 1X1N001 1X1N002 1X1N003 7-7 7-7 7-13 7-13 7-13 7-13 7-13 7-7 7-7 7-7 14-49 14-49 14-49 14-49 14-48 14-48 14-48 14-48 14-48 14-48 32 32 32 32 32 36 36 36 36 37 NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA NEMA 16-39 16-40 16-41 16-42 16-43 16-64 16-65 16-66 16-67 16-64 1BB1632Q 1BB2448Q 1D1N001 1D1N001QST 1D1N002 1D1N002QST 1D1N003 1D1N003QST 1D1N005 1D1N005QST 7-19 7-19 7-6 7-18 7-6 7-18 7-6 7-18 7-6 7-18 1X1N005 1X1N007 1X1N010 1X1N015 1X1N025 205BB1224Q 205BB1632Q 205BB2448Q 20STD1000 24CLP600 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog NEMA NEMA NEMA NEMA NEMA Catalog Number NEMA NEMA NEMA NEMA NEMA NEMA XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR XFMR 7-6 7-18 7-6 7-18 7-6 7-18 7-6 7-18 7-18 7-18 7-6 7-18 7-6 7-18 7-18 7-6 7-18 7-18 7-6 7-6 7-7 7-7 7-7 7-7 7-7 XFMR 7-19 XFMR 7-19 7-19 6-64 6-135 Product Index 2BB1224Q 2BB1632Q 2BB2448Q 2CLD20 2CLD20 2CLF350 2CLF350 2NLK1 2NLK18 2NLK2 XFMR XFMR 7-19 7-19 7-19 6-134 6-96 6-100 6-134 UNPB 10-12 UNPB 10-11 UNPB 10-12 3C5Y150TP1 3CLD20 3CLD20 3CLF350 3CLF350 3CLJ350 3CLJ350 3CLJ600 3CLJ600 3CLJ750 7-10 6-134 6-96 6-100 6-134 6-104 6-135 6-104 6-135 6-104 3F3Y150K4TP1 3F3Y150TE 3F3Y150TP1 3F3Y150TP1QST 3F3Y225K13TP1 3F3Y225K20TP1 3F3Y225K30TP1 3F3Y225K4TP1 3F3Y225RTP1QST 3F3Y225TP1 7-9 7-8 7-8 7-18 7-9 7-9 7-9 7-9 7-18 7-8 3LD2213-0TK__ 3LD2213-1TL53 3LD2244-0TK__ 3LD2244-1TL53 3LD2254-0TK__ 3LD2254-1TL__ 3LD2264-0TB51-0US1 3LD2264-0TB53-0US1 3LD2264-1GP51-0US1 3LD2264-1GP53-0US1 2NLK30 2NLK42 2TA2LG600LD 2TA2LG600LN 2TA2N8750 2TA2N8750 2TA2N8750 2TA3N8750 2TA3N8750 2TA3N8750 UNPB UNPB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 10-11 10-11 6-135 6-135 6-51 6-55 6-83 6-51 6-55 6-83 3CLJ750 3CLL750 3CLL750 3F1Y015TE 3F1Y015TP1 3F1Y015TP1QST 3F1Y030TE 3F1Y030TP1 3F1Y030TP1QST 3F1Y045TE 6-135 6-108 6-135 7-8 7-8 7-18 7-8 7-8 7-18 7-8 3F3Y300K13TP1 3F3Y300K20TP1 3F3Y300K30TP1 3F3Y300K4TP1 3F3Y300RTP1QST 3F3Y300TP1 3F3Y500K13TP1 3F3Y500K20TP1 3F3Y500K30TP1 3F3Y500K4TP1 7-9 7-9 7-9 7-9 7-18 7-8 7-9 7-9 7-9 7-9 3LD2264-1TS51-0US1 3LD2264-1TS53-0US1 3LD2264-2TW51-0US1 3LD2264-2TW53-0US1 3LD2504-0TK__ 3LD2504-3VK53 3LD2514-0TK__ 3LD2545-0TK__ 3LD2555-0TK__ 3LD2565-0TB51-0US1 HDSS HDSS HDSS HDSS 2TA3NG750 2TA4N8500 2TA4N8500 2TA4N8500 2TA4NG500 2TA4P8500 2TA4P8500 2TA4P8500 2TC2LG600LD 2TC2LG600LN MCCB 6-135 MCCB 6-51 MCCB 6-55 MCCB 6-82 6-135 MCCB 6-51 MCCB 6-55 MCCB 6-82 6-135 6-135 3F1Y045TP1 3F1Y045TP1QST 3F1Y075TE 3F1Y075TP1 3F1Y075TP1QST 3F1Y112TE 3F1Y112TP1 3F1Y112TP1QST 3F1Y150TE 3F1Y150TP1 7-8 7-18 7-8 7-8 7-18 7-8 7-8 7-18 7-8 7-8 3F3Y500RTP1QST 3F3Y500TP1 3F3Y750TP1 3F5R015 3F5Y015TP1 3F5Y030TP1 3F5Y045TP1 3F5Y075TP1 3F5Y112TP1 3F5Y150TP1 7-18 7-8 7-8 7-9 7-9 7-9 7-9 7-9 7-9 7-9 3LD2565-0TB53-0US1 3LD2565-1GP51-0US1 3LD2565-1GP53-0US1 3LD2704-0TK__ 3LD2714-0TK__ 3LD2766-0TB51-0US1 3LD2766-0TB53-0US1 3LD2766-1GP51-0US1 3LD2766-1GP53-0US1 3LD2804-0TK__ HDSS HDSS HDSS 3B1Y015TP1 3B1Y030TP1 3B1Y045TP1 3B1Y075TP1 3B1Y112TP1 3B1Y150TP1 3B1Y225TP1 3B3R003 3B3R006 3B3R009 7-10 7-10 7-10 7-10 7-10 7-10 7-10 7-10 7-10 7-10 3F1Y150TP1QST 3F1Y225TP1 3F1Y300TP1 3F1Y500TP1 3F1Y750TP1 3F2R003 3F2R006 3F2R009 3F2R015 3F3R003 7-18 7-8 7-8 7-8 7-8 7-8 7-8 7-8 7-8 7-8 3F5Y225TP1 3F5Y300TP1 3F5Y500TP1 3G3R003 3G3R006 3G3R009 3G3R015 3G3Y015TP1 3G3Y030TP1 3G3Y045TP1 7-9 7-9 7-9 7-11 7-11 7-11 7-11 7-11 7-11 7-11 3LD2814-0TK__ 3LD2866-0TB51-0US1 3LD2866-0TB53-0US1 3LD2866-1GP51-0US1 3LD2866-1GP53-0US1 3LD9200-5B 3LD9200-5BF 3LD9200-5C 3LD9200-5CF 3LD9220-0B 3B3R015 3B3S225TP1 3B3S300TP1 3B3S500TP1 3B3Y015TP1 3B3Y015XESTP1 3B3Y030TP1 3B3Y030XESTP1 3B3Y045TP1 3B3Y045XESTP1 7-10 7-10 7-10 7-10 7-10 7-12 7-10 7-12 7-10 7-12 3F3R003QST 3F3R006 3F3R006QST 3F3R009 3F3R009QST 3F3R015 3F3S000TP1 3F3Y015K13TP1 3F3Y015K20TP1 3F3Y015K30TP1 7-18 7-8 7-18 7-8 7-18 7-8 7-8 7-9 7-9 7-9 3G3Y075TP1 3G3Y112TP1 3G3Y150TP1 3G3Y225TP1 3G3Y300TP1 3G3Y500TP1 3G4R015A 3G4R030A 3G4R045A 3G4R075A 7-11 7-11 7-11 7-11 7-11 7-11 7-11 7-11 7-11 7-11 3B3Y075TP1 3B3Y075XESTP1 3B3Y112TP1 3B3Y112XESTP1 3B3Y150TP1 3B5R009 3B5R015 3B5R030TP1 3B5R045TP1 3B5R075TP1 7-10 7-12 7-10 7-12 7-10 7-10 7-10 7-10 7-10 7-10 3F3Y015K4TP1 3F3Y015TE 3F3Y015TP1 3F3Y015TP1QST 3F3Y015XESTP1 3F3Y030K13TP1 3F3Y030K20TP1 3F3Y030K30TP1 3F3Y030K4TP1 3F3Y030TE 7-9 7-8 7-8 7-18 7-12 7-9 7-9 7-9 7-9 7-8 3G4R112A 3G4R150A 3G4R225A 3G4R300A 3G4R500A 3G5R003 3G5R006 3G5R009 3G5R015 3G5Y015TP1 3B5R112TP1 3B5R150TP1 3B5S225TP1 3B5S300TP1 3B5S500TP1 3BB1224Q 3BB1632Q 3BB2448Q 3C3S225TP1 3C3S300TP1 7-10 7-10 7-10 7-10 7-10 7-19 7-19 7-19 7-10 7-10 3F3Y030TP1 3F3Y030TP1QST 3F3Y030XESTP1 3F3Y045K13TP1 3F3Y045K20TP1 3F3Y045K30TP1 3F3Y045K4TP1 3F3Y045TE 3F3Y045TP1 3F3Y045TP1QST 7-8 7-18 7-12 7-9 7-9 7-9 7-9 7-8 7-8 7-18 3G5Y030TP1 3G5Y045TP1 3G5Y075TP1 3G5Y112TP1 3G5Y150TP1 3G5Y225TP1 3G5Y300TP1 3G5Y500TP1 3LD2064-0TB51-0US1 3LD2064-0TB53-0US1 3C3S500TP1 3C3Y015TP1 3C3Y015XESTP1 3C3Y030TP1 3C3Y030XESTP1 3C3Y045TP1 3C3Y045XESTP1 3C3Y075TP1 3C3Y075XESTP1 3C3Y112TP1 7-10 7-10 7-12 7-10 7-12 7-10 7-12 7-10 7-12 7-10 3F3Y045XESTP1 3F3Y075K13TP1 3F3Y075K20TP1 3F3Y075K30TP1 3F3Y075K4TP1 3F3Y075TE 3F3Y075TP1 3F3Y075TP1QST 3F3Y075XESTP1 3F3Y112K13TP1 7-12 7-9 7-9 7-9 7-9 7-8 7-8 7-18 7-12 7-9 3LD2064-1GP51-0US1 3LD2064-1GP53-0US1 3LD2103-0TK__ 3LD2103-1TL__ 3LD2103-1TP__ 3LD2103-2EP__ 3LD2113-0TK__ 3LD2113-1TL__ 3LD2144-0TK__ 3LD2144-1TL__ 3C3Y112XESTP1 3C3Y150TP1 3C5S225TP1 3C5S300TP1 3C5S500TP1 3C5Y015TP1 3C5Y030TP1 3C5Y045TP1 3C5Y075TP1 3C5Y112TP1 7-12 7-10 7-10 7-10 7-10 7-10 7-10 7-10 7-10 7-10 3F3Y112K20TP1 3F3Y112K30TP1 3F3Y112K4TP1 3F3Y112TE 3F3Y112TP1 3F3Y112TP1QST 3F3Y112XESTP1 3F3Y150K13TP1 3F3Y150K20TP1 3F3Y150K30TP1 7-9 7-9 7-9 7-8 7-8 7-18 7-12 7-9 7-9 7-9 3LD2154-0TK__ 3LD2154-1TL__ 3LD2154-1TP__ 3LD2154-2EP__ 3LD2164-0TB51-0US1 3LD2164-0TB53-0US1 3LD2164-1GP51-0US1 3LD2164-1GP53-0US1 3LD2203-0TK__ 3LD2203-1TL__ XFMR XFMR XFMR Page Catalog Number Product Category Page XFMR XFMR XFMR Catalog Number Product Category Page HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS Catalog Number Product Category Page Catalog Number Product Category Page 4-3 4-3 4-3 4-3 4-2 4-2 3-32 3-32 3-32 3-32 3RT19 5 3RT19 6 3RT19 6 3RT19 6 3RT19 7 3RT19 7 3RU19 0 “3RV10, 13” 3RV19 3RW30/31 NEMA 16-86 16-155 16-156 NEMA 16-88 16-155 NEMA 16-88 NEMA 16-88 NEMA 16-10 IEC 16-80 NEMA 16-164 3-32 3-32 3-32 3-32 4-2 4-2 4-3 4-3 4-2 3-32 3RW40 3RW44 3RW44 3TA12JG04 3TA12JG04 3TA1DG30 3TA1DG30 3TA1EG10 3TA1EG10 3TA1EG10 IEC 16-165 IEC 16-166 IEC 16-167 6-104 6-135 MCCB 6-134 MCCB 6-96 MCCB 6-24 MCCB 6-32 MCCB 6-81 3-32 3-32 3-32 4-2 4-3 3-32 3-32 3-32 3-32 4-2 3TA1EG30 3TA1EG30 3TA1EG30 3TA1JG750 3TA1JG750 3TA1JG750 3TA1JG750 3TA2JG250 3TA2JG250 3TA2LG600LD MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-24 6-32 6-81 6-104 6-104 6-135 6-135 6-104 6-135 6-108 4-3 3-32 3-32 3-32 3-32 4-3 4-3 4-3 4-3 4-3 3TA2LG600LD 3TA2LG600LN 3TA2LG600LN 3TA2MG750 3TA2MG750 3TA2N8750 3TA2N8750 3TA2N8750 3TA2N8750 3TA3DG02 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-135 6-108 6-135 6-112 6-135 6-51 6-53 6-55 6-83 6-134 3LD9220-0C 3LD9220-2B 3LD9220-2C 3LD9220-2C 3LD9221-0A 3LD9221-0A 3LD9221-2A 3LD9221-2A 3LD9224-1B 3LD9224-1B 4-3 4-3 3-33 4-3 4-3 4-3 4-3 4-3 4-3 4-3 3TA3DG02 3TA3EG02 3TA3FG20 3TA3FG20 3TA3MG500 3TA3MG500 3TA3MG600 3TA3MG600 3TA3N8750 3TA3N8750 MCCB MCCB 6-96 6-83 6-100 6-134 6-112 6-135 6-112 6-135 6-51 6-53 7-11 7-11 7-11 7-11 7-11 7-11 7-11 7-11 7-11 7-11 3LD9224-1D 3LD9224-1D 3LD9224-3B 3LD9224-3B 3LD9224-3D 3LD9224-3D 3LD9250-0BA 3LD9250-0CA 3LD9250-2BA 3LD9250-2CA 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 3-33 3TA3N8750 3TA3N8750 3TA3NG750 3TA3NG750 3TA4N8500 3TA4N8500 3TA4N8500 3TA4N8500 3TA4NG500 3TA4NG500 MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB MCCB 6-55 6-83 6-116 6-135 6-51 6-53 6-55 6-82 6-116 6-135 7-11 7-11 7-11 7-11 7-11 7-11 7-11 7-11 3-32 3-32 3LD9250-2CA 3LD9251-0A 3LD9251-0A 3LD9251-2A 3LD9251-2A 3LD9280-0B 3LD9280-0C 3LD9280-2B 3LD9280-2C 3LD9280-2C 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 3-33 4-3 3TA4NG500H 3TA4NG500H 3TA4P8500 3TA4P8500 3TA4P8500 3TA4P8500 3TA6DG04 3TA6DG04 3TA6EG06 3TA6FG04 3-32 3-32 4-2 4-2 4-2 4-2 4-3 4-3 4-3 4-3 3LD9281-2A 3LD9281-2A 3LD9284-1B 3LD9284-1B 3LD9284-1D 3LD9284-1D 3LD9284-3B 3LD9284-3B 3LD9284-3D 3LD9284-3D 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 3TA6FG04 3TA6JG20 3TA6JG20 3TA6PG750 3TA6PG750 3TAW1FG350 3TAW1FG350 3TC1DG30 3TC1DG30 3TC1GG20 6-134 6-104 6-135 6-120 6-135 MCCB 6-100 MCCB 6-134 6-134 6-96 MCCB 6-22 4-2 4-2 4-2 4-2 3-32 3-32 3-32 3-32 4-2 4-2 3LPC009 3LPC015 3LPC022 3LPC030 3NW7 “3RA19 6, 7” 3RB20 3RB29 8 3RH19 21 3RP20 7-13 7-13 7-13 7-13 16-89 16-86 16-48 16-88 16-88 16-88 3TC1GG20 3TC1GG20 3TC1Q1 3TC1Q1 3TC1Q1 3TC2LG600LD 3TC2LG600LD 3TC2LG600LN 3TC2LG600LN 3TC4NG500 MCCB MCCB MCCB MCCB MCCB HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS HDSS NEMA NEMA NEMA NEMA NEMA NEMA Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog MCCB MCCB MCCB MCCB MCCB MCCB 6-116 6-135 6-51 6-53 6-55 6-82 6-134 6-96 6-83 6-100 6-30 6-81 6-22 6-30 6-81 6-108 6-135 6-108 6-135 6-116 19-27 PRODUCT INDEX Product Category 19 Catalog Number Product Index Catalog Number PRODUCT INDEX 19 3TC4NG500 3TC6PG750 3TC6PG750 3TCW1FG350 3TCW1FG350 3TW1DG20 3TW1DG20 3TW1EG30 3TW1EG30 3TW1FG350 Product Category MCCB MCCB MCCB MCCB Page Catalog Number Product Category Page 6-135 6-120 6-135 6-100 6-134 6-134 6-96 6-32 6-81 6-100 52PX9 52PX9 52RA1 52RA2 52RA4 52RA5 52RA6 52RA7 52RB3 52SA2 PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-201 16-207 16-211 16-212 16-211 16-211 16-212 16-212 16-211 16-193 52SA2 52SA3 52SA4 52SA7 52SB2 52SB2 52SC6 52SC6 52SW2 52SW2 PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-197 16-198 16-198 16-197 16-193 16-197 16-193 16-199 16-204 16-208 3TW1FG350 3TW1JG600 3TW1JG600 42NLK18 42NLK30 42NLK42 4MLKA1 4MLKA3 4MLKC1 4MLKC3 UNPB UNPB UNPB UNPB UNPB UNPB UNPB 6-134 6-104 6-135 10-11 10-11 10-11 10-11 10-11 10-11 10-11 505BB1224Q 505BB1632Q 505BB2448Q 50A 50B 50C 50C 50D 50D 50D XFMR XFMR XFMR PILO PILO PILO PILO PILO PILO PILO 7-19 7-19 7-19 16-181 16-181 16-181 16-182 16-181 16-182 16-183 52SX2 52SX2 5BB1224Q 5BB1632Q 5BB2448Q 64690-1 6CLE2 6CLF1 6CLJ1 6CLL1 50D 50E 50E 50F 50G 50H 50H 50J 50L 50M PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-187 16-182 16-183 16-184 16-184 16-184 16-186 16-185 16-185 16-184 6CLL350 6CLL350 6CLL600 6CLL600 6E62 6F62 6FPB01 6FPB01 6FPB01 6FPB02 SWBD SWBD SWBD SWBD SWBD SWBD 6-108 6-135 6-108 6-135 12-26 12-26 10-50 10-61 12-26 10-50 50M 50N 50R 50R 50Z 52AA 52AA 52AB 52ABT 52ABW PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-185 16-185 16-182 16-183 16-187 16-212 16-213 16-212 16-200 16-200 6FPB02 6FPB02 6FPB03 6FPB03 6FPB03 6FPB05 6FPB05 6FPB05 6FPB10 6FPB10 SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD 10-61 12-26 10-50 10-61 12-26 10-50 10-61 12-26 10-50 10-61 52AE 52AL 52AX 52BA 52BJ 52C1 52C2 52C3 52MA 52MA2 PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-213 16-212 16-212 16-213 16-213 16-216 16-216 16-217 16-212 16-200 6FPB10 6JJ61 6JJ62 6LL61 6QJ2 6SCJ1 6SCL1 6SJL1 6SLL1 705BB1224Q SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD SWBD XFMR 12-26 12-26 12-26 12-26 12-26 12-26 12-26 12-26 12-26 7-19 52MA3 52MA4 52NA 52ND 52NE 52NL 52NP02 52PA2 52PA2 52PA3 PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-200 16-200 16-219 16-219 16-219 16-219 16-200 16-191 16-196 16-191 705BB1632Q 705BB2448Q 73 73 73 74 74 74 74 74 XFMR XFMR IEC IEC IEC IEC IEC IEC IEC IEC 7-19 7-19 16-168 16-169 16-170 16-172 16-173 16-174 16-175 16-176 52PA3 52PA4 52PA6 52PA8 52PA8 52PB9 52PB9 52PC4 52PE3 52PE4 PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-192 16-194 16-195 16-190 16-196 16-190 16-196 16-194 16-191 16-191 8WA10 1 8WA18 1 9CLM500 9CLM500 NEMA 16-89 NEMA 16-89 6-112 6-135 52PE4 52PE6 52PX2 52PX2 52PX3 52PX3 52PX4 52PX6 52PX8 52PX8 PILO PILO PILO PILO PILO PILO PILO PILO PILO PILO 16-194 16-195 16-202 16-207 16-202 16-203 16-205 16-206 16-201 16-207 19-28 Catalog Number Product Category Page Catalog Number PILO 16-204 PILO 16-208 XFMR 7-19 XFMR 7-19 7-19 RESG 2-10 SWBD 12-26 SWBD 12-26 SWBD 12-26 SWBD 12-26 Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog Product Category Page Catalog Number Product Category Page We offer a wide variety of high quality products and modifications including combination and non-combination starters that are guaranteed for trouble-free operation. Space getting smaller? Siemens switchboards give you room to breathe. integrated modpro ModPro PlusTM means shorter turn-around for standard and modified NEMA control products. Instead of waiting on the factory, our ModPro Plus distributors can turn your order around as quickly as the same day. 쏘2007 Siemens Energy & Automation, Inc. 쏘2007 Siemens Energy & Automation, Inc. When Waiting Is Not An Option, ModPro Plus Delivers. s For more information or to contact a sales representative, call, e-mail, or visit our website. Siemens Energy & Automation, Inc. 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com/modproplus The Siemens integrated power systems switchboard provides a smaller, modular, reliable solution to meet the demanding space needs of the electrical room. Components such as power monitoring, lighting panels, transformers, and lighting control are all incorporated into one piece of equipment. One product, one supplier, and one invoice – it just makes sense. Ask your sales representative about using i-3 Control TechnologyTM in your IPS switchboard design. For more information or to contact a sales representative, call, e-mail, or visit our web site. Siemens Energy & Automation, Inc. 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com s SPEEDFAXTM 2007–2008 SPEEDFAXTM 2007–2008 Product Catalog Product Catalog power distribution 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com 쏘2007 Siemens Energy & Automation, Inc. All Rights Reserved. Siemens is a registered trademark of Siemens AG. Product names mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice. PDPC-01000-0607 (Supersedes PDPC-01000-0305) 150M0607RDD Printed in USA s Siemens Energy & Automation, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 Residential Commercial Industrial s
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Modify Date : 2008:11:19 20:44:32-05:00 Create Date : 2007:12:13 10:39:38-06:00 Metadata Date : 2008:11:19 20:44:32-05:00 Document ID : uuid:10d055fc-05c7-4c5d-9cee-fd86b69b39a9 Instance ID : uuid:29aa683d-2e38-4bb9-828a-51fd43d03f17 Format : application/pdf Title : PDPC-01000-0607 Creator : www.electricalmanuals.net Description : - CATALOGS - SIEMENS - SPEEDFAX - Producer : Creo Normalizer JTP Keywords : SPEEDFAX 2007–2008 Product Catalog Page Count : 940 Author : www.electricalmanuals.net Subject : - CATALOGS - SIEMENS - SPEEDFAX - Trapped : FalseEXIF Metadata provided by EXIF.tools