7MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
© 2009 Schneider Electric
All Rights Reserved 7-25
PowerPact® Circuit
Breakers
D- and M-Frame Circuit Breakers
Class 612, 615 / Refer to Catalogs: 0612CT0101, 0616CT0801
aD-frame circuit breakers 400 A and below are 100% rated. 600 A is
standard (80%) rated only.
bF = Fault indicator; T = Residual-type ground-fault protection; I = Ammeter
cAvailable with lugs (L) or bus (F) connections only.
fFor N, D, and S pricing, add termination pricing to price. See page 7-42.
gL interrupting rating is not available in M-frame.
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-36
Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-39
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-55
Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7-56
Table 7.51: D-Frame (600 A 600 Vac) 3P 50/60 Hz Circuit Breaker with Lugs and Electronic Trip Unitsc
Electronic Trip
Unit Type Trip
Function Trip Unit Continuous
Currenta
G Interrupting J Interrupting L Interrupting Terminal Wire Range (AWG/kcmil)
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
Standard
LS STR23SP
150 A DGL36150E20 5081.00 DJL36150E20 8478.00 DLL36150E20 9918.00
(1) 2–600 Cu or (1) 2–500 Al250 A DGL36250E20 5081.00 DJL36250E20 8478.00 DLL36250E20 9918.00
400 A DGL36400E20 5081.00 DJL36400E20 8478.00 DLL36400E20 9918.00
600 A DGL36600E20 8315.00 DJL36600E20 8865.00 DLL36600E20 13586.00 (2) 2/0–350 Cu or (2) 2/0–500 Al
LSI SR53UP-Fb
150 A DGL36150E53 6200.00 DJL36150E53 9597.00 DLL36150E53 11037.00
(1) 2–600 Cu or (1) 2–500 Al250 A DGL36250E53 6200.00 DJL36250E53 9597.00 DLL36250E53 11037.00
400 A DGL36400E53 6200.00 DJL36400E53 9597.00 DLL36400E53 11037.00
600 A DGL36600E53 9429.00 DJL36600E53 9984.00 DLL36600E53 14705.00 (2) 2/0–350 Cu or (2) 2/0–500 Al
LSIG STR53UP-FTb
150 A DGL36150E54 7527.00 DJL36150E54 10925.00 DLL36150E54 12365.00
(1) 2–600 Cu or (1) 2–500 Al250 A DGL36250E54 7527.00 DJL36250E54 10925.00 DLL36250E54 12365.00
400 A DGL36400E54 7527.00 DJL36400E54 10925.00 DLL36400E54 12365.00
600 A DGL36600E54 10761.00 DJL36600E54 11312.00 DLL36600E54 16032.00 (2) 2/0–350 Cu or (2) 2/0–500 Al
Ammeter
LSI STR53UP-FIb
150 A DGL36150E58 7661.00 DJL36150E58 11058.00 DLL36150E58 12498.00
(1) 2–600 Cu or (1) 2–500 Al250 A DGL36250E58 7661.00 DJL36250E58 11058.00 DLL36250E58 12498.00
400 A DGL36400E58 7661.00 DJL36400E58 11058.00 DLL36400E58 12498.00
600 A DGL36600E58 10895.00 DJL36600E58 11445.00 DLL36600E58 16166.00 (2) 2/0–350 Cu or (2) 2/0–500 Al
LSIG STR53UP-FTIb
150 A DGL36150E59 8990.00 DJL36150E59 12387.00 DLL36150E59 13827.00
(1) 2–600 Cu or (1) 2–500 Al250 A DGL36250E59 8990.00 DJL36250E59 12387.00 DLL36250E59 13827.00
400 A DGL36400E59 8990.00 DJL36400E59 12387.00 DLL36400E59 13827.00
600 A DGL36600E59 9434.00 DJL36600E59 12774.00 DLL36600E59 17495.00 (2) 2/0–350 Cu or (2) 2/0 –
500 Al
Table 7.52: D-Frame 3P 600 A Circuit Breaker, Frame Only, and Field-Installable Trip Units
Basic Frame Only (600 Vac)d Field Installable D-Frame Electronic Trip Unit
Ampere
Rating
G Interrupting J Interrupting L Interrupting Long-time, Short-time and Instantaneous Protection
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Description Factory Code Trip Function Cat. No. $ Price
150 A DGL36150F40 2766.00 DJL36150F40 6164.00 DLL36150F40 7602.00 STR23SP E20 LS 36940 2033.00
250 A DGL36250F40 2766.00 DJL36250F40 6164.00 DLL36250F60 7602.00 STR53UP-F E53 LSI 36942 3152.00
400 A DGL36400F40 2766.00 DJL36400F40 6164.00 DLL36400F40 7602.00 STR53UP-FT E54 LSIG 36943 4479.00
600 A DGL36600F60 5904.00 DJL36600F60 6456.00 DLL36600F60 11177.00 STR53UP-FI E58 LSI 36944 4613.00
dAvailable with lugs (L) or bus (F) connections only. STR53UP-FTI E59 LSIG 36945 5942.00
D-Frame Circuit Breaker
M-Frame Circuit Breaker
Table 7.53: M-Frame 800 A, Basic Electronic Trip System Type ET 1.0e Factory-Sealed Trip Unit
Electronic Trip
Unit Type Trip Function Sensor
Rating
G Interrupting J Interrupting Terminal Wire Range
(AWG/kcmil)
Cat. No. $ Price Cat. No. $ Price
2P, 600 Vac 50/60 Hz
Basic
Fixed
Long-time,
Adjustable
Instantaneous
Trip
300 A MGL26300 5960.00 MJL26300 7829.00
(3) 3/0–500
Al/Cu
350 A MGL26350 5960.00 MJL26350 7829.00
400 A MGL26400 5960.00 MJL26400 7829.00
450 A MGL26450 5960.00 MJL26450 7829.00
500 A MGL26500 5960.00 MJL26500 7829.00
600 A MGL26600 5960.00 MJL26600 7829.00
700 A MGL26700 7719.00 MJL26700 9657.00
800 A MGL26800 7719.00 MJL26800 9657.00
3P, 600 Vac 50/60 Hz
Basic
Fixed
Long-time,
Adjustable
Instantaneous
Trip
300 A MGL36300 7560.00 MJL36300 9456.00
(3) 3/0–500
Al/Cu
350 A MGL36350 7560.00 MJL36350 9456.00
400 A MGL36400 7560.00 MJL36400 9456.00
450 A MGL36450 7560.00 MJL36450 9456.00
500 A MGL36500 7560.00 MJL36500 9456.00
600 A MGL36600 7560.00 MJL36600 9456.00
700 A MGL36700 9927.00 MJL36700 11882.00
800 A MGL36800 9927.00 MJL36800 11882.00
eThe ET 1.0 trip unit cannot be field replaced or have the long-time trip point setting adjusted. It is considered an electronic equivalent of
a thermal-magnetic circuit breaker.
Table 7.54: Termination Options
Frame Termination
Letter Termination Option
D-Frame
F No Lugs (Includes terminal nut kit on both ends)
L Lugs both ends
M Lugs ON end Terminal Nut Kit Off end
P Lugs OFF end Terminal Nut Kit On end
N fPlug-in
D fDrawout
S fRear Connected
M-Frame
F No Lugs
L Lugs both ends
M Lugs ON end Terminal Nut Kit Off end
P Lugs OFF end Terminal Nut Kit On end
M G L 3 6 4 0 0 or
For factory-installed termination, place termination letter in
the third block of the circuit breaker catalog number.
Termination Letter
D G L 3 6 4 0 0 E 2 0
Table 7.55: D- and M-Frame Interrupting Ratings
Voltage Interrupting Rating
GJLg
240 Vac 65 kA 100 kA 150 kA
480 Vac 35 kA 65 kA 100 kA
600 Vac 18 kA 25 kA 25 kA
DE2 Discount
Schedule
www.schneider-electric.us
7MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
© 2009 Schneider Electric
All Rights Reserved 7-7
Selection Information Molded Case Circuit Breakers
Class 600, 612, 800
600 A L-Frame PowerPact 800 A M-Frame PowerPact 1200 A P-Frame 1000 A M-Frame
Circuit Breaker Type LX LXI LE MG MJ PG PJ PK PL MA MH MX ME
Number of Poles 3 3 3 2, 3 2, 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3 2, 3 3 3
Current Range 100–600 100–600 100–600 300–800 300–800 100–1200 100–1200 100–1200 100–1200 300–1200 300–1200 450–800 450–800
Interrupting Ratings
UL/CSA/NOM
Rating
(kA RMS)
(50/60 Hzb)
240 Vac 100 200 100 65 100 65 100 65 125 42 65 65 65
480Y/277 Vac 65 200 65 35 65 35 65 50 100 30 65 65 65
480 Vac 65 200 65 35 65 35 65 50 100 30 65 65 65
600Y/347 Vac 35 100 35 18 25 18 25 50 25 22 25 25 25
600 Vac 35 100 35 18 25 18 25 50 25 22 25 25 25
DC Ratings 250 Vdc 14 50
500 Vdca——— — ———20——
IEC
(kA RMS)
Icu/lcsc
240 Vac 50/25 65/35 50/25 65/35 50/25 125/65
415 Vac 65/65f—65/65f35/20 50/25 35/20 50/25 50/25 85/45 30/30 65/33 65/33 65/33
IEC 50/60 Hz For additional IEC ratings, see the
Supplemental Digest. For additional IEC ratings, see the
Supplemental Digest.
Special Ratings
Fed. Specs W-C-375B/GEN X X X X X X X X X X X X X
HACR (2P, 3P) X X X X X X X X
Connections/Terminations
Unit Mount X X X X X X X X X X X X X
I-Line®XXX X X XXXXX XXX
Rear Connection X X
Drawout — — — XeXeXeXe——
Optional Lugs X X X X X X X X X X X X X
Accessories and Modifications
Shunt Trip X X X X X X X X X X X XeXe
Undervoltage Trip X X X X X X X X X X X XeXe
Auxiliary Switches X X X X X X X X X X X XeXe
Alarm Switch X X X X X X X X X X X XeXe
Motor Operator XeXeXeXeXX
Handle Operators XeXeXeXeXXXX
Mechanical Interlocks (3P) X X X X XdXd——
Handle Padlock Attachment X X X X X X X X X X X X X
Cylinder Lock (3P) X X X X
Optional GF Protection XeXeXe — XXXX—XeXe
Trip System Type
Thermal-magnetic — — — — X X
Instantaneous-only (MCP) X X X X
Molded Case Switch (Automatic) X X X X X
Electronic X X X X X X X X X — — X X
Enclosures (Pages 7-56–7-58)
General Purpose (NEMA 1) X X X X X X X X X X
Raintight (NEMA 3R) X X X X X X X X X X
Dust-tight (NEMA 12) X X X X X X X X X X X X X
Watertight (NEMA 4, 4X, 5) X X X X X X
Explosion Proof (NEMA 7, 9)
Dimensions
(3P Unit Mount)
Height–in. (mm) 11.86 (301) 12.80 (325) 16.20 (413) 14 (356)
Width—in. (mm) 7.5 (190) 8.30 (210) 8.30 (210) 9 (229)
Depth—in. (mm) 6.74 (171) 8.10 (205) 8.10 (205) 6.5 (165)
Pages (Unit Mount)/(I-Line) Page 7-52/9-28 Page 7-25/9-28 Page 7-26, 7-30, 7-33/9-29 Supplemental Digest Section 3
Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
aUngrounded UPS systems only. See page 7-34.
bUL PowerPact MG/MJ and PG/PJ/PK/PL are 60 Hz only.
cDual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest.
dRequires breaker with WB suffix
eFactory-installed option only.
f65/50 kA Icu/Ics for 450–600 A ratings.
www.schneider-electric.us
7MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
7-54 © 2009 Schneider Electric
All Rights Reserved
Dimensions and Shipping Weights
Miniature and Molded Case Circuit Breakers
gDimensions E are 1.59 in at ON end and 0.63 in at OFF end.
hAll weights are for 3P circuit breakers unless otherwise noted.
BE
A
G
Figure 2
BE
A
G
Figure 1
BE
A
G
Figure 3
D
C
QO, QOB
QO-GFI, QO-PL
QO-EPD
D
C
Figure 5
A
G
B
E
A
BE
G
Figure 4
B
A
G
E
Figure 6
A
G
BE
Figure 7
A
G
BE
Figure 8
D
C
F
QOU, QYU
Low Ampere
A
D
C
B
Figure 9
QO-PLPS
Figure 10
A
BE
Figure 11
A
BE
Figure 12
A
BE
QOU
High Ampere
C
D
FB
Figure 13
A
B
Figure 14
A
B
Figure 15
A
B
Figure 16
A
B
C
D
C60
E
Figure 17
A
B
Figure 18
A
B
Figure 19
A
B
Figure 20
A
B
C120
C
D
E
B
Figure 21
B
E
FA
E
G
C/L
Figure 22
B
E
E
FA
Figure 23
C/L
B
D
C
G
HH
E
E
F
A
B
G
E
E
FA
D
C
Figure 24
Table 7.140: QO®, QOU, Multi 9TM Circuit Breakers
Circuit Breaker
Cat. No. Prefix Poles Fig.
No.
Dimensions—Inches
ABCDEFG
QO, QOB
1 1 0.75 3.00a2.31 2.91 2.25 0.59
2 2 1.50 3.00a2.31 2.91 2.25 1.34
3 3 2.25 3.00a2.31 2.91 2.25 2.09
QOB-VH 150 A
QOB-VH 110–150 A
2 2 3.0 5.72 2.53 4.90 3.78 2.85
3 3 4.50 5.72 2.53 4.90 3.78 4.35
QO-PL
QO-GFI
QO-EPD
1 4 0.75 4.12b2.31 2.91 2.25 0.59
2 5 1.50 4.12b2.31 2.91 2.25 1.34
3 5 2.25 4.12b2.31 2.91 2.25 2.09
QOU
QYU
Low Ampere
1 6 0.75 4.05c2.38 2.98 2.25 5.00d0.62
2 7 1.50 4.05c2.38 2.98 2.25 5.00d1.37
3 8 2.25 4.05d2.38 2.98 2.25 5.00f2.12
QOU
High Ampere
1 10 0.75 4.45 2.37 2.96 2.25 6.78
2 11 1.50 4.45 2.37 2.96 2.25 6.78
3 12 2.25 4.45 2.37 2.96 2.25 6.78
Multi 9™ C60N
1 13 0.71 3.19 1.73 2.76 1.77
2 14 1.42 3.19 1.73 2.76 1.77
3 15 2.13 3.19 1.73 2.76 1.77
4 16 2.84 3.19 1.73 2.76 1.77
QO-PLPS Power Supply 2 9 1.45 4.35 2.42 3.11
a35–70 A is 3.12 in; 80–100 A 2P and 70–100 A 3P are 3.50 in.
bQO-PL is 4.55 in.
c80–100 A 1P and 80–125 A 2P are 4.45 in
d80–100 A 1P and 80–125 A 2P are 6.78 in.
e70–100 A 4.45 in.
f70–100 A is 6.78 in.
Table 7.141: QB, QD, QG, QJ, Q4, FA, FI, KA, KC, KI, LA, LC, LI,
LE, LX, LXI, MA Circuit Breakers
Circuit Breaker
Cat. No. Prefix Poles Fig.
No.
Dimensions—Inches
ABCDEFGH
QB, QD,
QG, QJ
2 22 6.47 3.00 3.02 3.93 g4.25 —
3 23 6.47 4.50 3.02 3.93 g4.25 1.50 0.75
FAL, FHL
1 21 6.00 1.50 3.16 4.13 0.44 5.13 1.50
2 22 6.00 3.00 3.16 4.13 0.44 5.13
3 23 6.00 4.50 3.16 4.13 0.44 5.13 1.50 0.75
FIL, KAL, KCL,
KHL, KIL 2 & 3 23 8.00 4.50 3.66 4.75 0.44 7.13 1.50 0.75
Q4L, LAL, LHL 2 & 3 23 11.00 6.00 4.06 5.84 0.88 9.25 2.00 1.00
LIL, LEL, LXL, LXIL,
LCL 2 & 3 24 11.86 7.50 5.48 6.74 0.55 10.75 2.50
MAL, MHL 2 & 3 23 14.00 9.00 4.53 6.50 1.66 10.69 3.00 1.50
Table 7.142: Shipping Weightsh
Frame Size Approx. Shipping
Weight (Lbs.) Frame Size Approx. Shipping
Weight (Lbs.)
FAL, FHL 1P 2 KIL 9
FAL, FHL 2P 3 LAL, LHL 15
FAL, FHL 3P 5 LEL, LIL, LXL, LXIL, LCL 25
FIL 8 Q4L 15
QB, QD, QG, QJ 4 MAL, MHL 34
KAL, KHL 7
www.SquareD.com
For the most up-to-date information
6-36
Mechanical Accessories
Used on Thermal-magnetic and Electronic Trip Circuit Breakers
6CIRCUIT BREAKERS
© 2005 Schneider Electric
All Rights Reserved
3/21/05
3/21/05
DE2 Discount
Schedule
bLocks OFF only.
cMA and MH circuit breakers will not lock in ON position.
dUse with MAHEX handle extension.
Circuit Breaker
Prefix
No. of
Poles Catalog No. Price
Handle Padlock Attachment (locks ON or OFF)
FY Series 1
Q2
1
2,3
HPAFYQ
HPAFYQ $13.20
QB, QD, QG, QJ 2,3 QBPA 51.50
QBPAFb
FA, FH, FC, FI 1,2,3 HPAFK 16.10
FY Series 2, KA, KH 2,3 HPAFK 16.10
KC, KI 2,3 HPAFKFb21.70
LA, LH, MA, MH, Q4 2,3 HPALMc
HPAXLMd
17.30
18.40
LC, LE, LI, LX, LXI 2,3 AHPALI 16.80
PA, PC, PH, PE, PX 2, 3 PAPAF 79.00
Handle Extension
MA, MH 2,3 MAHEX 63.00
LA, LC, LH, LE, LI,
LX, LXI, Q4 2,3 AHEXLI 63.00
Electrical Operators
Provides remote ON, OFF/RESET control of molded case circuit breakers.
A complete line of field-installable electrical operators.
Not applicable on LC/LI/LE/LX/LXI, ME/MX, NA/NC/NE/NX, PG/PJ/PL, RG/RJ/RL
circuit breakers.
Installing side mounted motor operators on non I-Line® circuit breakers requires the
use of a separate mounting pan.
Side mounted electrical operators require an additional 412 in. (114 mm) of
mounting space in I-Line installations.
When remote indication of circuit breaker status is required, order circuit breaker with 1A-1B auxilliary switch for ON-
OFF Indication and alarm switch for TRIP Indication. Electrical operators require SPDT maintained contact switch. Refer
to Class 9001 control unit listing for operators and pilot lights.
Circuit
Breaker
Prefix
Top Mount Side Mount Mounting Pan
Voltage Catalog No. Price Voltage Catalog No. Price Catalog No. Price
FA, FH, FC . . . . . . . . . 120 Vac FAMO1 $869. . . . . . .
FAL, FHL,
FCL . . .. . .. . . 120 Vac FAMO1 869. FAMOP $72.
FI, KA, KH,
KC, KI . . .. . .. . . 120 Vac KAMO1 2337. . . . . . .
FIL, KIL,
KAL, KHL,
KCL
120 Vac KAMO2120AC $2312.
120 Vac KAMO1 2337. KAMOP 89.
240 Vac KAMO2240AC 2312.
24 Vdc KAMO224DC 2312.
125 Vdc KAMO2125DC 2312.
LA, LH, Q4 . . . . . . . . . 120 Vac LAMO1 3012. . . . . . .
LAL, LHL,
Q4L
120 Vac LAMO2120AC 2987.
120 Vac LAMO1 3012. LAMOP 123.
240 Vac LAMO2240AC 2987.
24 Vdc LAMO224DC 2987.
125 Vdc LAMO2125DC 2987.
MA, MH . . . . . . . . . 120 Vac MAMO1 3012. . . . . . .
MAL, MHL
120 Vac MAMO2120AC 2987.
120 Vac MAMO1 3012. MAMOP 123.
240 Vac MAMO2240AC 2987.
24 Vdc MAMO224DC 2987.
125 Vdc MAMO2125DC 2987.
PA, PH, PC,
PE, PX 120 Vac PAMO2 3520. . . . . . . . . . . . . . . .
Breaker Prefix No. of Poles Catalog. No. Price
Handle Tie
(2)FA 3 FKHT $143.00
(2)KA,
(2)FI,(2)KI, or
(1)FI + (1)KI
2,3 FKHT 143.00
(2)LA or
(2)Q4 2,3 LAHT 331.00
California Title 24 Comb. Handle Tie and Lock Off
FY
FA
(3)1-pole
(3)1-pole
FY3HT
FA3HT
34.80
34.80
See pages 6-51–6-54 for Enclosures.
Fully enclosed interlocked units are available in Type 1 and Type 3R enclosures, with two neutrals provided
in each enclosure.The completely enclosed assembly is not UL Listed. Please consult your nearest
Square D/Schneider Electric sales office for more information.
See pages 6-40–6-42 for accessories for Powerpact® circuit breakers.
Walking Beam Mechanical Interlock Components
Circuit Breaker Price
Adder
Walking Beam Ass'y. Mounting Pan
Prefix Suffix Catalog No. Price Catalog No. Price
Manually Operated
FAL, FHL
KAL
LAL, LHL
MAL, MHL
WB
WB
WB
WB
$164.
164.
164.
164.
FA4WB
KA4WB
LA6WB
MA9WB
$85.
85.
113.
136.
FAWBP4
KAWBP4
LAWBP6
MAWBP9
$118.
118.
161.
206.
Electrically Operated
FAL, FHL
KAL
LAL, LHL
MAL, MHL
WBMO
WBMO
WBMO
WB
$164.
164.
164.
164.
FA9WB
KA9WB
LA10WB
MA13WB
$127.
127.
135.
159.
FAWBP9
KAWBP9
LAWBP10
MAWBP13
$161.
161.
206.
286.
Front Mounted Mechanical Interlock
Circuit Breaker
Prefix
No. of
Poles Catalog No. Price
Q2, QB, QD, QG, QJ 2, 3 QBMIK $60.
Walking Beam Mechanical Interlock
Requires two circuit breakers with WB suffix,
one walking beam assembly and one mounting pan.
QBMIK
FAMO1 and FAMOP
With FAL Circuit Breaker
KAMO2120AC
With KAL Circuit Breaker
aNot available on Mag-Gard circuit breakers and molded case switches.
Cylinder Lock
Used to lock the circuit breaker in the OFF position.
Circuit breaker cannot be reset when locked OFF.
Circuit
Breaker
Prefix
Catalog Number
Price
Factory Inst.
Suffix Field Inst.
FA, FAL, FH, FHLa—CL Factory-installed
Only
$210.
KA, KAL, KH, KHLa210.
LA, LAL, LH, LHL, Q4 Field-installable
Only
LA1CL 210.
MA, MAL, MH, MHL MA1CL 210.

Navigation menu