Schneider Electric/Square D Terminal Blocks Fuseholders And Power Distribution Brochure
2014-07-30
: Pdf 107121-Brochure 107121-Brochure 785901 Batch6 unilog
Open the PDF directly: View PDF .
Page Count: 11
Download | ![]() |
Open PDF In Browser | View PDF |
Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Miniature Standard Maximum Voltage Rating 600 600 600 Service Class C C C 600 C Amperage Rating - CU Wire 115 amp. 115 amp. 175 amp. 175 amp. Amperage Rating - AL Wire 90 amp. 90 amp. 135 amp. 135 amp. SCCR with Circuit Breakers See page 27 See page 27 N/A See page 28 SCCR with Fuses Wire Range Lugs suitable for use with 75° C Conductors. Tightening Torque See page 29 See page 29 See page 29 See page 29 Main Main Main Main (1) #14-2 AWG (1) #14-2 AWG (1) #14-2/0 AWG (1) #14-2/0 AWG Branch Branch Branch Branch (1) #14-2 AWG (4) #18-10 AWG (1) #14-2/0 AWG (4) #14-4 AWG Main Main Main Main #3-#2 / 50 lbf-in / (5.6 N-m) #3-#2 / 50 lbf-in / (5.6 N-m) #6-2/0 / 120 lbf-in / (13.5 N-m) #6-2/0 / 120 lbf-in / (13.5 N-m) #6-#4 / 45 lbf-in / (5.1 N-m) #6-#4 / 45 lbf-in / (5.1 N-m) #8 / 40 lbf-in / (4.5 N-m) #8 / 40 lbf-in / (4.5 N-m) #8 / 40 lbf-in / (4.5 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) #8 / 40 lbf-in / (4.5 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) Branch Branch Branch #3-#2 / 50 lbf-in / (5.6 N-m) #18-#10 / 7 lbf-in / (0.8 N-m) #6-2/0 / 120 lbf-in / (13.5 N-m) #14-#4 / 35 lbf-in / (4.0 N-m) Branch #6-#4 / 45 lbf-in / (5.1 N-m) #8 / 40 lbf-in / (4.5 N-m) #8 / 40 lbf-in / (4.5 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) Lug Material Tin Plated High Conductive AL Tin Plated High Tin Plated High Conductive AL Conductive AL Conductive AL Base Material High Impact Thermoplastic High Impact Thermoplastic General Purpose Phenolic General Purpose Phenolic Temperature Rating -40 to 257° F -40 to 125° C -40 to 257° F -40 to 125° C -40 to 302° F -40 to 150° C -40 to 302° F -40 to 150° C Certifications Flammability Rating File E60616 Guide XCFR2 UL94V-0 ¨ File 70361 / Class 6228-01 UL94V-0 Tin Plated High RoHS Compliant Marked UL94V-0 UL94V-0 One Pole Blocks Block Catalog Number 9080LBA161101 9080LBA161104 9080LBA162101 9080LBA162104 Clear Plastic Covers N/A N/A 9080LB21 9080LB21 Block Dimensions (D x H x W) 1.53 x 2.29 x 0.76 in. 38.8 x 58.2 x 19.3 mm 1.53 x 2.29 x 0.83 in. 38.8 x 58.2 x 21.08 mm (including dovetail) 1.78 x 2.88 x 1.13 in. 45.2 x 73.2 x 28.7 mm 1.78 x 2.88 x 1.13 in. 45.2 x 73.2 x 28.7 mm Block Catalog Number N/A 9080LBA261104 9080LBA262101 9080LBA262104 Clear Plastic covers N/A N/A 9080LB22 9080LB22 N/A 1.53 x 2.29 x 1.46 in. 38.8 x 58.2 x 37.08 mm (including dovetail) 1.78 x 2.88 x 1.94 in. 45.2 x 73.2 x 49.3 mm 1.78 x 2.88 x 1.94 in. 45.2 x 73.2 x 49.3 mm Two Pole Blocks Block Dimensions (D x H x W) Three Pole Blocks Block Catalog Number 9080LBA361101 9080LBA361104 9080LBA362101 9080LBA362104 Clear Plastic covers N/A N/A 9080LB23 9080LB23 1.53 x 2.29 x 2.03 in. 38.8 x 58.2 x 51.6 mm 1.53 x 2.29 x 2.1 in. 38.8 x 58.2 x 53.34 mm (including dovetail) 1.78 x 2.88 x 2.75 in. 45.2 x 73.2 x 69.9 mm 1.78 x 2.88 x 2.75 in. 45.2 x 73.2 x 69.9 mm Block Dimensions (D x H x W) 6 04/2009 © 1993 - 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Standard Maximum Voltage Rating 600 600 600 Service Class C C C C Amperage Rating-CU Wire 310 amp. 335 amp. 335 amp. 350 amp. Amperage Rating-AL Wire 250 amp. 270 amp. 270 amp. 270 amp. SCCR w/Circuit Breakers N/A See page 27 See page 28 See page 28 SCCR with Fuses Wire Range Lugs suitable for use with 75° C Conductors. Tightening Torque N/A MAIN See page 29 MAIN (1) #6 - 350 MCM BRANCH (1) #6 - 350 MCM See page 29 MAIN (1) #6 - 400 MCM BRANCH See page 29 MAIN (1) #6 - 500 MCM BRANCH (4) #14 - #2 AWG 600 (2) #14 - 2/0 AWG BRANCH (6) #14 - #2 AWG (6) #14 - #4AWG MAIN MAIN MAIN MAIN #6-350 MCM / 275 lbf-in / (31.0 N-m) #6-400 MCM / 275 lbf-in / (31.0 N-m) #6-400 MCM / 275 lbf-in / (31.0 N-m) #6-2/0 / 120 lbf-in / (13.5 N-m) BRANCH BRANCH BRANCH #6-350 MCM / 275 lbf-in / (31.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) #3-#2 / 50 lbf-in / (5.6 N-m) #3-#2 / 50 lbf-in / (5.6 N-m) BRANCH #6-#4 / 45 lbf-in / (5.1 N-m) #6-#4 / 45 lbf-in / (5.1 N-m) #14-#4 / 35 lbf-in / (4.0 N-m) #8 / 40 lbf-in / (4.5 N-m) #8 / 40 lbf-in / (4.5 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) #8 / 40 lbf-in / (4.5 N-m) Lug Material Tin Plated High Conductive AL Tin Plated High Conductive AL Tin Plated High Conductive AL Tin Plated High Conductive AL Base Material General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic -40 to 302°F -40 to 302° F -40 to 302° F -40 to 302° F -40 to 150°C -40 to 150° C -40 to 150° C -40 to 150° C Temperature Rating File E60616 Guide XCFR2 Certifications Flammability Rating UL94V-0 ¨ File 70361 / Class 6228-01 UL94V-0 RoHS Compliant Marked UL94V-0 UL94V-0 9080LBA163206 One Pole Blocks Block Catalog Number 9080LBA163101 9080LBA163104 9080LBA163106 Clear Plastic Covers 9080LB31 9080LB31 9080LB31 9080LB31 Block Dimensions 2.61 x 4.00 x 1.94 in. 2.61 x 4.00 x 1.94 in. 2.61 x 4.00 x 1.94 in. 2.61 x 4.00 x 1.94 in. (D) x (H) x (W) 66.3 x 101.6 x 49.3 mm 66.3 x 101.6 x 49.3 mm 66.3 x 101.6 x 49.3 mm 66.3 x 101.6 x 49.3 mm Two Pole Blocks Block Catalog Number 9080LBA263101 9080LBA263104 9080LBA263106 9080LBA263206 Clear Plastic covers 9080LB32 9080LB32 9080LB32 9080LB32 Block Dimensions ((Dx H x W) 2.61 x 4.00 x 3.47 in. 66.3 x 101.6 x 88.1 mm 2.61 x 4.00 x 3.47 in. 66.3 x 101.6 x 88.1 mm 2.61 x 4.00 x 3.47 in. 66.3 x 101.6 x 88.1 mm 2.61 x 4.00 x 3.47 in. 66.3 x 101.6 x 88.1 mm Block Catalog Number 9080LBA363101 9080LBA363104 9080LBA363106 9080LBA363206 Clear Plastic covers 9080LB33 9080LB33 9080LB33 9080LB33 Block Dimensions 2.61 x 4.00 x 5.00 in. 66.3 x 101.6 x 27.0 mm 2.61 x 4.00 x 5.00 in. 66.3 x 101.6 x 127.0 mm 2.61 x 4.00 x 5.00 in. 66.3 x 101.6 x 127.0 mm 2.61 x 4.00 x 5.00 in. 66.3 x 101.6 x 127.0 mm Three Pole Blocks (D x H x W) © 1993 - 2009 Schneider Electric All Rights Reserved 7 04/2009 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Standard Maximum Voltage Rating 600 600 600 Service Class C C C C Amperage Rating-CU Wire 420 amp. 335 amp. 380 amp. 380 amp. Amperage Rating-AL Wire 340 amp. 270 amp. 310 amp. 310 amp. SCCR w/Circuit Breakers N/A See page 27 See page 27 See page 27 SCCR with Fuses Wire Range Lugs suitable for use with 75° C Conductors. See page 29 MAIN See page 29 MAIN (1) #4-600 MCM BRANCH (1) #4-600 MCM (1) #6-400 MCM (8) #14-2 AWG BRANCH #6-400 MCM 500 lbf-in (56.5 N-m) (1) #4-500 MCM BRANCH (6) #14-2/0 AWG (12) #14-2 AWG MAIN #4-500 MCM 275 lbf-in (31.0 N-m) BRANCH #4-600 MCM (1) #4-500 MCM MAIN 500 lbf-in (56.5 N-m) Tightening Torque See page 29 MAIN BRANCH MAIN #4-600 MCM See page 29 MAIN BRANCH MAIN 600 #4-500 MCM 375 lbf-in (42.3 N-m) BRANCH BRANCH #3-#2 50 lbf-in (5.6 N-m) #6-2/0 120 lbf-in (13.5 N-m) #3-#2 #6-#4 45 lbf-in (5.1 N-m) #8 #6-#4 45 lbf-in (5.1 N-m) #8 40 lbf-in (4.5 N-m) #14-#10 35 lbf-in (4.0 N-m) #8 40 lbf-in (4.5 N-m) 40 lbf-in (4.5 N-m) #14-#10 35 lbf-in (4.0 N-m) Lug Material Base Material Temperature Rating Certifications Flammability Rating 375 lbf-in (42.3 N-m) 50 lbf-in (5.6 N-m) #14-#10 35 lbf-in (4.0 N-m) Tin Plated High Conductive AL Tin Plated High Conductive AL Tin Plated High Conductive AL Tin Plated High Conductive AL General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic -40 to 302° F -40 to 302° F -40 to 302° F -40 to 302° F -40 to 150° C -40 to 150° C -40 to 150° C -40 to 150° C File E60616 Guide XCFR2 UL94V-0 ¨ File 70361 / Class 6228-01 UL94V-0 RoHS Compliant General Purpose Phenolic Marked UL94V-0 UL94V-0 9080LBA165112 One Pole Blocks Block Catalog Number 9080LBA164101 9080LBA164108 9080LBA165106 Clear Plastic covers 9080LB41 9080LB41 9080LB51 9080LB51 Block Dimensions 2.90 x 4.75 x 2.29 in. 2.90 x 4.75 x 2.29 in. 3.12 x 5.50 x 3.17 in. 3.12 x 5.50 x 3.17 in. (D x H x W) 80.3 x 120.7 x 57.2 mm 80.3 x 120.7 x 57.2 mm 79.2 x 139.7 x 80.5 mm 79.2 x 139.7 x 80.5 mm Two Pole Blocks Block Catalog Number N/A 9080LBA264108 9080LBA265106 9080LBA265112 Clear Plastic covers N/A 9080LB42 9080LB52 9080LB52 Block Dimensions (D x H x W) N/A 2.90 x 4.75 x 4.17 in. 3.12 x 5.50 x 5.85 in. 3.12 x 5.50 x 5.85 in. 80.3 x 120.7 x 104.6 mm 79.2 x 139.7 x 149.4 mm 79.2 x 139.7 x 149.4 mm 9080LBA365112 Three Pole Blocks Block Catalog Number 9080LBA364101 9080LBA364108 9080LBA365106 Clear Plastic covers 9080LB43 9080LB43 9080LB53 9080LB53 Block Dimensions 2.90 x 4.75 x 6.05 in. 2.90 x 4.75 x 6.05 in. 3.12 x 5.50 x 8.54 in. 3.12 x 5.50 x 8.54 in. (D x H x W) 80.3 x 120.7 x 152.4 mm 80.3 x 120.7 x 152.4 mm 79.2 x 139.7 x 216.9 mm 79.2 x 139.7 x 216.9 mm 8 04/2009 © 1993 - 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Standard Maximum Voltage Rating 600 600 600 Service Class C C C C Amperage Rating-CU Wire 620 amp. 760 amp. 760 amp. 760 amp. Amperage Rating-AL Wire 500 amp. 620 amp. 620 amp. 620 amp. SCCR w/Circuit Breakers N/A N/A N/A N/A SCCR with Fuses See page 29 See page 29 See page 29 See page 30 Wire Range Lugs suitable for use with 75° C Conductors. 600 MAIN MAIN MAIN MAIN (2) #6 - 350 MCM (2) #4 - 500 MCM (2) #4 - 500 MCM (2) #4 - 500 MCM BRANCH BRANCH BRANCH BRANCH (2) #6 - 350 MCM (2) #4 - 500 MCM (8) #14 - 2/0 AWG (12) #14-4 AWG MAIN MAIN MAIN MAIN #6-350 MCM / 275 lbf-in / (31.0 #4-500 MCM / 375 lbf-in / (42.3 #4-500 MCM / 375 lbf-in / (42.3 #4-500 MCM / 375 lbf-in / (42.3 N-m) N-m) N-m) N-m) Tightening Torque BRANCH BRANCH #6-350 MCM / 275 lbf-in / (31.0 #4-500 MCM / 375 lbf-in / (42.3 #6-2/0 / 120 lbf-in / (13.5 N-m) N-m) N-m) #8 / 40 lbf-in / (4.5 N-m) BRANCH BRANCH #14-#4 / 35 lbf-in / (4.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m) Lug Material Tin Plated High Conductive AL Tin Plated High Conductive AL Tin Plated High Conductive AL Base Material General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic Temperature Rating -40 to 302° F -40 to 150° C -40 to 302° F -40 to 150° C -40 to 302° F -40 to 150° C -40 to 302° F -40 to 150° C File E60616 Guide XCFR2 Certifications Flammability Rating UL94V-0 ¨ File 70361 / Class 6228-01 UL94V-0 RoHS Compliant Tin Plated High Conductive AL Marked UL94V-0 UL94V-0 9080LBA165212 One Pole Blocks Block Catalog Number 9080LBA165202 9080LBA1652021 9080LBA165208 Clear Plastic covers 9080LB51 9080LB51 9080LB51 9080LB51 Block Dimensions 3.12 x 5.50 x 3.17 in. 3.12 x 5.50 x 3.17 in. 3.12 x 5.50 x 3.17 in. 3 .12 x 5.50 x 3.17 in. (D) x (H) x (W) 79.2 x 139.7 x 80.5 mm 79.2 x 139.7 x 80.5 mm 79.2 x 139.7 x 80.5 mm 79.2 x 139.7 x 80.5 mm 9080LBA265212 Two Pole Blocks Block Catalog Number 9080LBA265202 9080LBA2652021 9080LBA265208 Clear Plastic covers 9080LB52 9080LB52 9080LB52 9080LB52 Block Dimensions 3.12 x 5.50 x 5.85 in. 3.12 x 5.50 x 5.85 in. 3.12 x 5.50 x 5.85 in. 3.12 x 5.50 x 5.85 in. (D) x (H) x (W) 79.2 x 139.7 x 149.4 mm 79.2 x 139.7 x 149.4 mm 79.2 x 139.7 x 149.4 mm 79.2 x 139.7 x 149.4 mm 9080LBA365212 Three Pole Blocks Block Catalog Number 9080LBA365202 9080LBA3652021 9080LBA365208 Clear Plastic covers 9080LB53 9080LB53 9080LB53 9080LB53 Block Dimensions 3.12 x 5.50 x 8.54 in. 3.12 x 5.50 x 8.54 in. 3.12 x 5.50 x 8.54 in. 3.12 x 5.50 x 8.54 in. (D) x (H) x (W) 79.2 x 139.7 x 216.9 mm 79.2 x 139.7 x 216.9 mm 79.2 x 139.7 x 216.9 mm 79.2 x 139.7 x 216.9 mm © 1993 - 2009 Schneider Electric All Rights Reserved 9 04/2009 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks 9080LBA and 9080LBC Power Distribution Blocks Copper or Aluminum/Only Copper Wire Class 9080 Standard Maximum Voltage Rating 600 600 600 600 Service Class C C C C Amperage Rating-CU Wire 175 A 150 A 175 A 255 A Amperage Rating-AL Wire 135 A N/A N/A N/A SCCR w/Circuit Breakers SCCR with Fuses See page 27 See page 29 See page 28 N/A See page 28 See page 30 N/A N/A Wire Range MAIN - (1) #14-2/0 AWG Lugs suitable for use with 75° C BRANCH - (6) #14-#4 AWG Conductors. MAIN: Tightening Torque MAIN - (1) #18-1/0 AWG MAIN - (1) #14-2/0 AWG MAIN - (1) #6-250 MCM BRANCH - (1) #18-1/0 AWG BRANCH - (4) #14-#4 AWG BRANCH - (1) #6-250 MCM MAIN MAIN MAIN #6-2/0 / 120 lbf-in / (13.5 N-m) #3-1/0 / 50 lbf-in /(5.6 N-m) #6-2/0 120 lbf-in (13.5 N-m) #6-250 MCM / #8 / 40 lbf-in (4.5 N-m) #6-#4 / 45 lbf-in / (5.1 N-m) #8 40 lbf-in (4.5 N-m) #14-#10 / 35 lbf-in (4.0 N-m) #8 / 40 lbf-in / (4.5 N-m) #14-#10 35 lbf-in (4.0 N-m) 375 lbf-in (42.3 N-m) #18-#10 / 35 lbf-in / (4.0 N-m) BRANCH BRANCH BRANCH #14-#4 / 35 lbf-in / (4.0 N-m) #3-1/0 / 50 lbf-in / (5.6 N-m) #14-#4 BRANCH 35 lbf-in (4.0 N-m) #6-250 MCM / #6-#4 / 45 lbf-in / (5.1 N-m) 375 lbf-in (42.3 N-m) #8 / 40 lbf-in / (4.5 N-m) #18-#10 / 35 lbf-in / (4.0 N-m) Lug Material Tin Plated High Conductive AL Tin Plated High Conductive CU Tin Plated High Conductive CU Tin Plated High Conductive CU Base Material General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic Temperature Rating -40 to 302° F -40 to 150° C -40 to 302° F -40 to 150° C -40 to 302° F -40 to 150° C -40 to 302° F -40 to 150° C Certifications File E60616 Guide XCFR2 Flammability Rating UL94V-0 Block Catalog Number N/A Clear Plastic covers N/A N/A ¨ File 70361 / Class 6228-01 UL94V-0 RoHS Compliant Marked UL94V-0 UL94V-0 9080LBC162101 9080LBC162104 9080LBC163101 9080LB21 9080LB21 9080LB31 1.78 x 2.88 x 1.13 in. 45.2 x 73.2 x 28.7 mm 1.78 x 2.88 x 1.13 in. 45.2 x 73.2 x 28.7 mm 2.61 x 4.00 x 1.94 in. 66.3 x 101.6 x 49.3 mm One Pole Blocks Block Dimensions (D) x (H) x (W) Two Pole Blocks Block Catalog Number N/A N/A 9080LBC262104 N/A Clear Plastic covers N/A N/A 9080LB22 N/A Block Dimensions (D) x (H) x (W) N/A N/A 1.78 x 2.88 x 1.94 in. 45.2 x 73.2 x 49.3 mm N/A Three Pole Blocks Block Catalog Number 9080LBA362106 9080LBC362101 9080LBC362104 9080LBC363101 Clear Plastic covers 9080LB23 9080LB23 9080LB23 9080LB33 Block Dimensions (D) x (H) x (W) 2.10 x 2.90 x 5.38 in. 53.3 x 73.7 x 136.7 mm 1.78 x 2.88 x 2.75 in. 45.2 x 73.2 x 69.9 mm 1.78 x 2.88 x 2.75 in. 45.2 x 73.2 x 69.9 mm 2.61 x 4.00 x 5.00 in. 66.3 x 101.6 x 127.0 mm 9080FBDIN3 N/A N/A N/A DIN 3 (35 mm) Track Adapter 10 04/2009 © 1993 - 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks 9080LBC Power Distribution Blocks Copper Wire Only Class 9080 Standard Maximum Voltage Rating 600 600 600 Service Class C C C C Amperage Rating-CU Wire 380 amp. 350 amp. 760 amp. 760 amp. Amperage Rating-AL Wire N/A N/A N/A N/A SCCR w/Circuit Breakers N/A See page 28 N/A N/A SCCR with Fuses See page 30 See page 30 See page 30 See page 30 Wire Range Lugs suitable for use with 75° C Conductors. MAIN MAIN (1) #4 - 500 MCM BRANCH BRANCH (6) #14-2 AWG MAIN #4-500 MCM 375 lbf-in (42.3 N-m) BRANCH Tightening Torque MAIN (2) #14 - 2/0 AWG #3-#2 50 lbf-in (5.6 N-m) #6-#4 45 lbf-in (5.1 N-m) #8 40 lbf-in (4.5 N-m) #14-#10 35 lbf-in (4.0 N-m) MAIN (2) #4 - 500 MCM BRANCH (6) #14 - #4 AWG #6-2/0 120 lbf-in (13.5 N-m) #8 40 lbf-in (4.5 N-m) #14-#10 35 lbf-in (4.0 N-m) BRANCH #14-#4 35 lbf-in (4.0 N-m) (2) #4 - 500 MCM BRANCH (8) #14 - 2/0 AWG MAIN MAIN 600 (12) #14-2 AWG MAIN #4-500 MCM - #4-500 MCM - 375 lbf-in (42.3 N-m) BRANCH #6-2/0 375 lbf-in (42.3 N-m) BRANCH 120 lbf-in (13.5 N-m) #3-#2 #8 40 lbf-in (4.5 N-m) #6-#4 50 lbf-in (5.6 N-m) 45 lbf-in (5.1 N-m) #14-#10 35 lbf-in (4.0 N-m) #8 40 lbf-in (4.5 N-m) #14-#10 35 lbf-in (4.0 N-m) Tin Plated High Tin Plated High Tin Plated High Conductive CU Conductive CU Conductive CU Conductive CU General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic General Purpose Phenolic Lug Material Base Material Temperature Rating -40 to 302° F -40 to 302° F -40 to 302° F -40 to 302° F -40 to 150° C -40 to 150° C -40 to 150° C -40 to 150° C File E60616 Guide XCFR2 Certifications Flammability Rating Tin Plated High UL94V-0 ¨ File 70361 / Class 6228-01 UL94V-0 RoHS Compliant Marked UL94V-0 UL94V-0 9080LBC165212 One Pole Blocks Block Catalog Number 9080LBC163106 9080LBC163206 9080LBC165208 Clear Plastic covers 9080LB31 9080LB31 9080LB51 9080LB51 Block Dimensions 2.61 x 4.00 x 1.94 in. 2.61 x 4.00 x 1.94 in. 3.12 x 5.50 x 3.17 in. 3.12 x 5.50 x 3.17 in. (D) x (H) x (W) 66.3 x 101.6 x 49.3 mm 66.3 x 101.6 x 49.3 mm 79.2 x 139.7 x 80.5 mm 79.2 x 139.7 x 80.5 mm Two Pole Blocks Block Catalog Number 9080LBC263106 9080LBC263206 N/A N/A Clear Plastic covers 9080LB32 9080LB32 N/A N/A N/A N/A Block Dimensions 2.61 x 4.00 x 3.47 in. 2.61 x 4.00 x 3.47 in. (D) x (H) x (W) 66.3 x 101.6 x 88.1 mm 66.3 x 101.6 x 88.1 mm Block Catalog Number 9080LBC363106 9080LBC363206 9080LBC365208 9080LBC365212 Clear Plastic covers 9080LB33 9080LB33 9080LB53 9080LB53 Three Pole Blocks Block Dimensions 2.61 x 4.00 x 5.00 in. 2.61 x 4.00 x 5.00 in. 3.12 x 5.50 x 8.54 in. 3.12 x 5.50 x 8.54 in. (D) x (H) x (W) 66.3 x 101.6 x 127.0 mm 66.3 x 101.6 x 127.0 mm 79.2 x 139.7 x 216.9 mm 79.2 x 139.7 x 216.9 mm © 1993 - 2009 Schneider Electric All Rights Reserved 11 04/2009 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks 9080LBA and 9080LBC Power Distribution Block Approximate Dimensions 9080LBA/9080LBC9080LBa/LBC A2 A1 A3 J- Mounting Hole Dia. B G D E D E E F D C H A1 A2 A3 B C D E F G H J LBA161101 LBA161104 1 Pole N/A LBA261104 2 Pole LBA361101 LBA361104 3 Pole 0.76 1.40 2.03 2.29 1.53 0.38 0.64 0.19 1.93 0.32 0.201 LAB162101 LBA162104 LBC162101 LBC162104 LBA262101 LBA262104 N/A LBC262104 LBA362101 LBA362104 LBC362101 LBC362104 1.13 1.94 2.75 2.88 1.78 0.56 0.81 0.31 2.25 0.24 0.205 LBA163101 LBA163104 LBA163106 LBA163206 LBC163101 LBC163106 LBC163206 LBA263101 LBA263104 LBA263106 LBA263206 N/A LBC263106 LBC263206 LBA363101 LBA363104 LBA363106 LBA363206 LBC363101 LBC363106 LBC363206 1.94 3.47 5.00 4.00 2.61 0.97 1.53 0.31 3.38 0.40 0.203 LBA164101 LBA164108 N/A LBA264108 LBA364101 LBA364108 2.28 4.16 6.04 4.75 2.92 1.14 1.88 0.31 4.13 0.51 0.200 LBA165202 LBA1652021 LBA165106 LBA165112 LBA165212 LBC165208 LBC165212 LBA265202 LBA2652021 LBA265106 LBA265112 LBA265212 N/A N/A LBA365202 LBA3652021 LBA365106 LBA365112 LBA365212 LBC365208 LBC365212 3.17 5.85 8.54 5.50 3.12 1.58 2.69 0.38 4.75 0.50 0.265 USE A #8 SELF TAPPING SCREW FOR MOUNTING COMPONENT .218 x .375 [5.5 x 9.5] SLOT .265 x .375 [6.7 x 9.5] SLOT .50 13 1.00 25.4 1.45 36.8 4.63 117.5 2.90 73.7 1.07 27 4.77 121 .50 13 5.37 136.4 .60 15.2 2.06 52.3 DIN Rail Adapter .38 9.5 Dimensions: in. [mm] LBA362106 20 04/2009 © 1993 - 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks UL Short Circuit Current Ratings Table 3: 9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Circuit Breakers Cat No. Suitable Conductors MCM / AWG CU Line Load Overcurrent Protection Circuit Breaker Required Mfr. Type Max A SCCR, RMS Sym A JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA 9080LBA161101 JLL36250 250 65 kA 9080LBA361101 HDL36100 100 18 kA 2-6 8-10 2 -6 8-10 Square D Square D 9080LBA161104 9080LBA261104 8- 10 (4) 14 Square D 9080LBA361104 9080LBA362106 2/0 -6 (6) 4- 10 Square D 9080LBA165106 9080LBA265106 2/0 -4 6) 8 Square D 9080LBA365106 9080LBA165112 9080LBA265112 2/0 -4 12) 2 -8 Square D 9080LBA365112 9080LBA164108 9080LBA264108 2/0 -6 6) 2 - 10 Square D 9080LBA364108 9080LBA163104 9080LBA263104 2/0 -4 9080LBA363104 © 1993 - 2009 Schneider Electric All Rights Reserved 4) 2 -8 Square D HGL36100 100 35 kA HJL36100 100 65 kA HLL36100 100 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA HDL36100 100 18 kA HGL36100 100 35 kA HJL36100 100 65 kA HLL36100 100 65 kA 18 kA JDL36250 250 JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA Volts Max 480 480 480 480 480 480 480 27 04/2009 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks UL Short Circuit Current Ratings Table 3: 9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Circuit Breakers (continued) Cat No. Suitable Conductors MCM / AWG CU Line Load Overcurrent Protection Circuit Breaker Required Mfr. 9080LBA163206 9080LBA263206 2) 1/0 -8 6) 4- 10 Square D 9080LBA363206 2) 2/0 -2 6) 4-8 Square D 9080LBC163206 9080LBC263206 9080LBC363206 2) 4-6 9080LBC162101 9080LBC362101 1/0 -8 6) 10-12 1/0 -8 Square D Square D 9080LBA163106 9080LBA263106 2/0 -6 6) 2 - 10 Square D 9080LBA363106 9080LBA162104 9080LBA262104 2/0 - 10 4) 4- 10 Square D 9080LBA362104 9080LBC162104 9080LBC262104 9080LBC362104 2/0 -8 4) 4-8 Square D Type Max A SCCR, RMS Sym A JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36175 175 18 kA JGL36175 175 35 kA JJL36175 175 65 kA JLL36175 175 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA JGL36250 250 35 kA JJL36250 250 65 kA JLL36250 250 65 kA JDL36250 250 18 kA Volts Max 480 480 480 480 480 480 28 04/2009 © 1993 - 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks UL Short Circuit Current Ratings Table 4: 9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Fuses Suitable Conductors MCM / AWG CU Catalog Number 1 Pole 2 Pole 3 Pole 9080LBA161101 N/A 9080LBA361101 9080LBA161104 9080LBA261104 9080LBA361104 9080LBA162101 9080LBA262101 9080LBA162104 Line Fuse Type / Amperage Load J T RK1 RK5 G CC SCCR Volts Max 2-6 2-6 200 200 200 100 60 30 100 kA 600 8-10 8-10 100 100 100 – 60 30 100 kA 600 2-6 10-14 200 200 200 100 60 30 200 kA 600 8-10 10-14 100 100 100 30 60 30 100 kA 600 9080LBA362101 2/0-6 2/0-6 300 300 200 100 60 30 65 kA 600 9080LBA262104 9080LBA362104 2/0-6 4-14 200 200 200 100 60 30 100 kA 600 N/A N/A 9080LBA362106 2/0-6 4-14 9080LBA163101 9080LBA263101 9080LBA363101 9080LBA163104 9080LBA263104 9080LBA363104 9080LBA163106 9080LBA263106 9080LBA363206 9080LBA164101 N/A 9080LBA364101 9080LBA164108 9080LBA264108 9080LBA364108 9080LBA165202 9080LBA265202 9080LBA1652021 – – 60 – 100 kA 600 200 100 – 30 200 kA 600 400-3/0 2-8 400 400 400 100 60 30 100 kA 600 2/0-6 2-14 200 200 200 100 60 30 100 kA 600 400-3/0 2-8 400 400 400 200 – 30 200 kA 600 600 – – – 60 – 100 kA 600 200 200 200 100 – 30 200 kA 600 – – – – 60 – 100 kA 600 2/0-6 9080LBA263206 – 200 N/A 9080LBA363106 9080LBA163206 – 200 2-14 (2)2/0-2 4-8 400 400 400 100 60 30 100 kA 600 (2)4-6 10-14 300 300 200 100 60 30 100 kA 600 600-2 600-2 600 600 – – – – 50 kA 600 400 400 400 200 60 30 100 kA 600 400-3/0 2-8 400 400 400 200 60 30 100 kA 600 2/0-6 2-14 200 200 200 100 60 30 100 kA 600 9080LBA365202 (2)350-4 (2)350-4 450 450 400 200 60 30 100 kA 600 600 600 – – – – 50 kA 600 9080LBA2652021 9080LBA3652021 (2)500-4 (2)500-4 600 600 400 200 60 30 100 kA 600 9080LBA165106 9080LBA265106 9080LBA365106 500-3/0 2/0-6 400 400 400 100 60 30 100 kA 600 2/0-4 8-14 200 200 200 100 60 30 100 kA 600 9080LBA165112 9080LBA265112 9080LBA365112 500-3/0 2-8 400 400 400 200 60 30 100 kA 600 2/0-4 2-14 200 200 200 100 60 30 100 kA 600 (2)500-250 2/0-4 600 9080LBA165208 9080LBA265208 9080LBA365208 © 1993 - 2009 Schneider Electric All Rights Reserved (2)4/0-4 2/0-10 600 600 400 200 60 30 100 kA 600 600 – – – – 50 kA 600 400 400 400 200 60 30 100 kA 600 29 04/2009 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Terminal Blocks UL Short Circuit Current Ratings Table 4: 9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Fuses (continued) Suitable Conductors MCM / AWG CU Catalog Number 1 Pole 9080LBA165212 2 Pole 9080LBA265212 3 Pole Line Load (2)500-250 4-8 9080LBA365212 (2)4/0-4 9080LBC162101 N/A 9080LBC362101 9080LBC162104 9080LBC262104 9080LBC362104 9080LBC163101 N/A 9080LBC363101 9080LBC163106 9080LBC263106 9080LBC363106 9080LBC163206 9080LBC263206 9080LBC363206 9080LBC165208 N/A 9080LBC365208 9080LBC165212 N/A 4-14 Fuse Type / Amperage J T RK1 RK5 G CC SCCR Volts Max 600 600 600 600 N/A N/A N/A 50 kA 400 400 400 200 60 30 100 kA 600 600 600 N/A N/A N/A N/A 50 kA 600 400 400 400 200 60 30 100 kA 600 100 60 30 100 kA 600 N/A 2/0-6 4-14 200 200 200 N/A 500-3/0 2-8 400 400 400 200 60 30 100 kA 600 2/0-4 2-14 200 200 200 100 60 30 100 kA 600 (2)2/0-2 4-8 400 400 400 100 60 30 100 kA 600 (2)4-6 10-14 200 200 200 100 60 30 100 kA 600 (2)500-250 2/0-4 (2)4/0-4 2/0-6 (2)500-250 2-8 9080LBC365212 (2)4/0-4 2-14 600 600 400 200 60 30 100 kA 600 600 600 N/A N/A N/A N/A 50 kA 600 400 400 400 200 60 30 100 kA 600 600 600 600 – – – 50 kA 600 400 400 400 200 60 30 100 kA 600 600 600 – – – – 50 kA 600 400 400 400 200 60 30 100 kA 600 30 04/2009 © 1993 - 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : MRAI46 Create Date : 2009:05:06 14:01:35-07:00 Modify Date : 2009:05:06 14:17:47-07:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Metadata Date : 2009:05:06 14:17:47-07:00 Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Title : Schneider Electric/Square D Terminal Blocks - Fuseholders and Power Distribution Blocks Creator : MRAI46 Document ID : uuid:fcab38b1-9558-ce40-8def-8cb9b6865695 Instance ID : uuid:2ae2f506-1151-8f46-a738-ff3d9e14beba Producer : Acrobat Distiller 7.0.5 (Windows) Page Count : 11EXIF Metadata provided by EXIF.tools