Terminal Blocks
9080LBA Power Distribution Blocks Copper or Aluminum Wire
Class 9080

Miniature

Standard

Maximum Voltage Rating

600

600

600

Service Class

C

C

C

600
C

Amperage Rating - CU Wire

115 amp.

115 amp.

175 amp.

175 amp.

Amperage Rating - AL Wire

90 amp.

90 amp.

135 amp.

135 amp.

SCCR with Circuit Breakers

See page 27

See page 27

N/A

See page 28

SCCR with Fuses
Wire Range
Lugs suitable for use with
75° C Conductors.

Tightening Torque

See page 29

See page 29

See page 29

See page 29

Main

Main

Main

Main

(1) #14-2 AWG

(1) #14-2 AWG

(1) #14-2/0 AWG

(1) #14-2/0 AWG

Branch

Branch

Branch

Branch

(1) #14-2 AWG

(4) #18-10 AWG

(1) #14-2/0 AWG

(4) #14-4 AWG

Main

Main

Main

Main

#3-#2 / 50 lbf-in / (5.6 N-m)

#3-#2 / 50 lbf-in / (5.6 N-m)

#6-2/0 / 120 lbf-in / (13.5 N-m) #6-2/0 / 120 lbf-in / (13.5 N-m)

#6-#4 / 45 lbf-in / (5.1 N-m)

#6-#4 / 45 lbf-in / (5.1 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m) #14-#10 / 35 lbf-in / (4.0 N-m)
Branch

Branch

Branch

#3-#2 / 50 lbf-in / (5.6 N-m)

#18-#10 / 7 lbf-in / (0.8 N-m)

#6-2/0 / 120 lbf-in / (13.5 N-m) #14-#4 / 35 lbf-in / (4.0 N-m)

Branch

#6-#4 / 45 lbf-in / (5.1 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m)
Lug Material

Tin Plated High Conductive
AL

Tin Plated High

Tin Plated High

Conductive AL

Conductive AL

Conductive AL

Base Material

High Impact Thermoplastic

High Impact Thermoplastic

General Purpose Phenolic

General Purpose Phenolic

Temperature Rating

-40 to 257° F
-40 to 125° C

-40 to 257° F
-40 to 125° C

-40 to 302° F
-40 to 150° C

-40 to 302° F
-40 to 150° C

Certifications
Flammability Rating

File E60616 Guide XCFR2

UL94V-0

¨

File 70361 / Class 6228-01

UL94V-0

Tin Plated High

RoHS Compliant

Marked

UL94V-0

UL94V-0

One Pole Blocks
Block Catalog Number

9080LBA161101

9080LBA161104

9080LBA162101

9080LBA162104

Clear Plastic Covers

N/A

N/A

9080LB21

9080LB21

Block Dimensions
(D x H x W)

1.53 x 2.29 x 0.76 in.
38.8 x 58.2 x 19.3 mm

1.53 x 2.29 x 0.83 in.
38.8 x 58.2 x 21.08 mm
(including dovetail)

1.78 x 2.88 x 1.13 in.
45.2 x 73.2 x 28.7 mm

1.78 x 2.88 x 1.13 in.
45.2 x 73.2 x 28.7 mm

Block Catalog Number

N/A

9080LBA261104

9080LBA262101

9080LBA262104

Clear Plastic covers

N/A

N/A

9080LB22

9080LB22

N/A

1.53 x 2.29 x 1.46 in.
38.8 x 58.2 x 37.08 mm
(including dovetail)

1.78 x 2.88 x 1.94 in.
45.2 x 73.2 x 49.3 mm

1.78 x 2.88 x 1.94 in.
45.2 x 73.2 x 49.3 mm

Two Pole Blocks

Block Dimensions
(D x H x W)

Three Pole Blocks
Block Catalog Number

9080LBA361101

9080LBA361104

9080LBA362101

9080LBA362104

Clear Plastic covers

N/A

N/A

9080LB23

9080LB23

1.53 x 2.29 x 2.03 in.
38.8 x 58.2 x 51.6 mm

1.53 x 2.29 x 2.1 in.
38.8 x 58.2 x 53.34 mm
(including dovetail)

1.78 x 2.88 x 2.75 in.
45.2 x 73.2 x 69.9 mm

1.78 x 2.88 x 2.75 in.
45.2 x 73.2 x 69.9 mm

Block Dimensions
(D x H x W)

6
04/2009

© 1993 - 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
9080LBA Power Distribution Blocks Copper or Aluminum Wire
Class 9080

Standard

Maximum Voltage Rating

600

600

600

Service Class

C

C

C

C

Amperage Rating-CU Wire

310 amp.

335 amp.

335 amp.

350 amp.

Amperage Rating-AL Wire

250 amp.

270 amp.

270 amp.

270 amp.

SCCR w/Circuit Breakers

N/A

See page 27

See page 28

See page 28

SCCR with Fuses
Wire Range
Lugs suitable for use
with
75° C Conductors.

Tightening Torque

N/A
MAIN

See page 29
MAIN

(1) #6 - 350 MCM
BRANCH
(1) #6 - 350 MCM

See page 29
MAIN

(1) #6 - 400 MCM
BRANCH

See page 29
MAIN

(1) #6 - 500 MCM
BRANCH

(4) #14 - #2 AWG

600

(2) #14 - 2/0 AWG
BRANCH

(6) #14 - #2 AWG

(6) #14 - #4AWG

MAIN

MAIN

MAIN

MAIN

#6-350 MCM / 275 lbf-in /
(31.0 N-m)

#6-400 MCM / 275 lbf-in / (31.0
N-m)

#6-400 MCM / 275 lbf-in / (31.0
N-m)

#6-2/0 / 120 lbf-in / (13.5 N-m)

BRANCH

BRANCH

BRANCH

#6-350 MCM / 275 lbf-in /
(31.0 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m)

#3-#2 / 50 lbf-in / (5.6 N-m)

#3-#2 / 50 lbf-in / (5.6 N-m)

BRANCH

#6-#4 / 45 lbf-in / (5.1 N-m)

#6-#4 / 45 lbf-in / (5.1 N-m)

#14-#4 / 35 lbf-in / (4.0 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m)

#8 / 40 lbf-in / (4.5 N-m)

Lug Material

Tin Plated High Conductive AL

Tin Plated High Conductive AL

Tin Plated High Conductive AL

Tin Plated High Conductive AL

Base Material

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

-40 to 302°F

-40 to 302° F

-40 to 302° F

-40 to 302° F

-40 to 150°C

-40 to 150° C

-40 to 150° C

-40 to 150° C

Temperature Rating

File E60616 Guide XCFR2

Certifications
Flammability Rating

UL94V-0

¨

File 70361 / Class 6228-01

UL94V-0

RoHS Compliant

Marked

UL94V-0

UL94V-0
9080LBA163206

One Pole Blocks
Block Catalog Number

9080LBA163101

9080LBA163104

9080LBA163106

Clear Plastic Covers

9080LB31

9080LB31

9080LB31

9080LB31

Block Dimensions

2.61 x 4.00 x 1.94 in.

2.61 x 4.00 x 1.94 in.

2.61 x 4.00 x 1.94 in.

2.61 x 4.00 x 1.94 in.

(D) x (H) x (W)

66.3 x 101.6 x 49.3 mm

66.3 x 101.6 x 49.3 mm

66.3 x 101.6 x 49.3 mm

66.3 x 101.6 x 49.3 mm

Two Pole Blocks
Block Catalog Number

9080LBA263101

9080LBA263104

9080LBA263106

9080LBA263206

Clear Plastic covers

9080LB32

9080LB32

9080LB32

9080LB32

Block Dimensions
((Dx H x W)

2.61 x 4.00 x 3.47 in.
66.3 x 101.6 x 88.1 mm

2.61 x 4.00 x 3.47 in.
66.3 x 101.6 x 88.1 mm

2.61 x 4.00 x 3.47 in.
66.3 x 101.6 x 88.1 mm

2.61 x 4.00 x 3.47 in.
66.3 x 101.6 x 88.1 mm

Block Catalog Number

9080LBA363101

9080LBA363104

9080LBA363106

9080LBA363206

Clear Plastic covers

9080LB33

9080LB33

9080LB33

9080LB33

Block Dimensions

2.61 x 4.00 x 5.00 in.
66.3 x 101.6 x 27.0 mm

2.61 x 4.00 x 5.00 in.
66.3 x 101.6 x 127.0 mm

2.61 x 4.00 x 5.00 in.
66.3 x 101.6 x 127.0 mm

2.61 x 4.00 x 5.00 in.
66.3 x 101.6 x 127.0 mm

Three Pole Blocks

(D x H x W)

© 1993 - 2009 Schneider Electric
All Rights Reserved

7
04/2009

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
9080LBA Power Distribution Blocks Copper or Aluminum Wire
Class 9080

Standard

Maximum Voltage Rating

600

600

600

Service Class

C

C

C

C

Amperage Rating-CU Wire

420 amp.

335 amp.

380 amp.

380 amp.

Amperage Rating-AL Wire

340 amp.

270 amp.

310 amp.

310 amp.

SCCR w/Circuit Breakers

N/A

See page 27

See page 27

See page 27

SCCR with Fuses
Wire Range
Lugs suitable for use with
75° C Conductors.

See page 29
MAIN

See page 29
MAIN

(1) #4-600 MCM
BRANCH
(1) #4-600 MCM

(1) #6-400 MCM
(8) #14-2 AWG

BRANCH

#6-400 MCM

500 lbf-in (56.5 N-m)

(1) #4-500 MCM
BRANCH

(6) #14-2/0 AWG

(12) #14-2 AWG
MAIN

#4-500 MCM

275 lbf-in (31.0 N-m)
BRANCH

#4-600 MCM

(1) #4-500 MCM

MAIN

500 lbf-in (56.5 N-m)
Tightening Torque

See page 29
MAIN

BRANCH

MAIN

#4-600 MCM

See page 29
MAIN

BRANCH

MAIN

600

#4-500 MCM

375 lbf-in (42.3 N-m)
BRANCH

BRANCH

#3-#2

50 lbf-in (5.6 N-m)

#6-2/0 120 lbf-in (13.5 N-m)

#3-#2

#6-#4

45 lbf-in (5.1 N-m)

#8

#6-#4

45 lbf-in (5.1 N-m)

#8

40 lbf-in (4.5 N-m)

#14-#10 35 lbf-in (4.0 N-m)

#8

40 lbf-in (4.5 N-m)

40 lbf-in (4.5 N-m)

#14-#10 35 lbf-in (4.0 N-m)
Lug Material
Base Material
Temperature Rating

Certifications
Flammability Rating

375 lbf-in (42.3 N-m)

50 lbf-in (5.6 N-m)

#14-#10 35 lbf-in (4.0 N-m)

Tin Plated High Conductive AL Tin Plated High Conductive AL Tin Plated High Conductive AL Tin Plated High Conductive AL
General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

-40 to 302° F

-40 to 302° F

-40 to 302° F

-40 to 302° F

-40 to 150° C

-40 to 150° C

-40 to 150° C

-40 to 150° C

File E60616 Guide XCFR2

UL94V-0

¨

File 70361 / Class 6228-01

UL94V-0

RoHS Compliant

General Purpose Phenolic

Marked

UL94V-0

UL94V-0
9080LBA165112

One Pole Blocks
Block Catalog Number

9080LBA164101

9080LBA164108

9080LBA165106

Clear Plastic covers

9080LB41

9080LB41

9080LB51

9080LB51

Block Dimensions

2.90 x 4.75 x 2.29 in.

2.90 x 4.75 x 2.29 in.

3.12 x 5.50 x 3.17 in.

3.12 x 5.50 x 3.17 in.

(D x H x W)

80.3 x 120.7 x 57.2 mm

80.3 x 120.7 x 57.2 mm

79.2 x 139.7 x 80.5 mm

79.2 x 139.7 x 80.5 mm

Two Pole Blocks
Block Catalog Number

N/A

9080LBA264108

9080LBA265106

9080LBA265112

Clear Plastic covers

N/A

9080LB42

9080LB52

9080LB52

Block Dimensions
(D x H x W)

N/A

2.90 x 4.75 x 4.17 in.

3.12 x 5.50 x 5.85 in.

3.12 x 5.50 x 5.85 in.

80.3 x 120.7 x 104.6 mm

79.2 x 139.7 x 149.4 mm

79.2 x 139.7 x 149.4 mm
9080LBA365112

Three Pole Blocks
Block Catalog Number

9080LBA364101

9080LBA364108

9080LBA365106

Clear Plastic covers

9080LB43

9080LB43

9080LB53

9080LB53

Block Dimensions

2.90 x 4.75 x 6.05 in.

2.90 x 4.75 x 6.05 in.

3.12 x 5.50 x 8.54 in.

3.12 x 5.50 x 8.54 in.

(D x H x W)

80.3 x 120.7 x 152.4 mm

80.3 x 120.7 x 152.4 mm

79.2 x 139.7 x 216.9 mm

79.2 x 139.7 x 216.9 mm

8
04/2009

© 1993 - 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
9080LBA Power Distribution Blocks Copper or Aluminum Wire
Class 9080

Standard

Maximum Voltage Rating

600

600

600

Service Class

C

C

C

C

Amperage Rating-CU Wire

620 amp.

760 amp.

760 amp.

760 amp.

Amperage Rating-AL Wire

500 amp.

620 amp.

620 amp.

620 amp.

SCCR w/Circuit Breakers

N/A

N/A

N/A

N/A

SCCR with Fuses

See page 29

See page 29

See page 29

See page 30

Wire Range
Lugs suitable for use with
75° C Conductors.

600

MAIN

MAIN

MAIN

MAIN

(2) #6 - 350 MCM

(2) #4 - 500 MCM

(2) #4 - 500 MCM

(2) #4 - 500 MCM

BRANCH

BRANCH

BRANCH

BRANCH

(2) #6 - 350 MCM

(2) #4 - 500 MCM

(8) #14 - 2/0 AWG

(12) #14-4 AWG

MAIN

MAIN

MAIN

MAIN

#6-350 MCM / 275 lbf-in / (31.0 #4-500 MCM / 375 lbf-in / (42.3 #4-500 MCM / 375 lbf-in / (42.3 #4-500 MCM / 375 lbf-in / (42.3
N-m)
N-m)
N-m)
N-m)
Tightening Torque

BRANCH
BRANCH
#6-350 MCM / 275 lbf-in / (31.0 #4-500 MCM / 375 lbf-in / (42.3 #6-2/0 / 120 lbf-in / (13.5 N-m)
N-m)
N-m)
#8 / 40 lbf-in / (4.5 N-m)
BRANCH

BRANCH
#14-#4 / 35 lbf-in / (4.0 N-m)

#14-#10 / 35 lbf-in / (4.0 N-m)
Lug Material

Tin Plated High Conductive AL

Tin Plated High Conductive AL Tin Plated High Conductive AL

Base Material

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

Temperature Rating

-40 to 302° F
-40 to 150° C

-40 to 302° F
-40 to 150° C

-40 to 302° F
-40 to 150° C

-40 to 302° F
-40 to 150° C

File E60616 Guide XCFR2

Certifications
Flammability Rating

UL94V-0

¨

File 70361 / Class 6228-01

UL94V-0

RoHS Compliant

Tin Plated High Conductive AL

Marked

UL94V-0

UL94V-0
9080LBA165212

One Pole Blocks
Block Catalog Number

9080LBA165202

9080LBA1652021

9080LBA165208

Clear Plastic covers

9080LB51

9080LB51

9080LB51

9080LB51

Block Dimensions

3.12 x 5.50 x 3.17 in.

3.12 x 5.50 x 3.17 in.

3.12 x 5.50 x 3.17 in.

3 .12 x 5.50 x 3.17 in.

(D) x (H) x (W)

79.2 x 139.7 x 80.5 mm

79.2 x 139.7 x 80.5 mm

79.2 x 139.7 x 80.5 mm

79.2 x 139.7 x 80.5 mm
9080LBA265212

Two Pole Blocks
Block Catalog Number

9080LBA265202

9080LBA2652021

9080LBA265208

Clear Plastic covers

9080LB52

9080LB52

9080LB52

9080LB52

Block Dimensions

3.12 x 5.50 x 5.85 in.

3.12 x 5.50 x 5.85 in.

3.12 x 5.50 x 5.85 in.

3.12 x 5.50 x 5.85 in.

(D) x (H) x (W)

79.2 x 139.7 x 149.4 mm

79.2 x 139.7 x 149.4 mm

79.2 x 139.7 x 149.4 mm

79.2 x 139.7 x 149.4 mm
9080LBA365212

Three Pole Blocks
Block Catalog Number

9080LBA365202

9080LBA3652021

9080LBA365208

Clear Plastic covers

9080LB53

9080LB53

9080LB53

9080LB53

Block Dimensions

3.12 x 5.50 x 8.54 in.

3.12 x 5.50 x 8.54 in.

3.12 x 5.50 x 8.54 in.

3.12 x 5.50 x 8.54 in.

(D) x (H) x (W)

79.2 x 139.7 x 216.9 mm

79.2 x 139.7 x 216.9 mm

79.2 x 139.7 x 216.9 mm

79.2 x 139.7 x 216.9 mm

© 1993 - 2009 Schneider Electric
All Rights Reserved

9
04/2009

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
9080LBA and 9080LBC Power Distribution Blocks Copper or Aluminum/Only Copper Wire
Class 9080

Standard

Maximum Voltage Rating

600

600

600

600

Service Class

C

C

C

C

Amperage Rating-CU Wire

175 A

150 A

175 A

255 A

Amperage Rating-AL Wire

135 A

N/A

N/A

N/A

SCCR w/Circuit Breakers
SCCR with Fuses

See page 27
See page 29

See page 28
N/A

See page 28
See page 30

N/A
N/A

Wire Range
MAIN - (1) #14-2/0 AWG
Lugs suitable for use with 75° C
BRANCH - (6) #14-#4 AWG
Conductors.
MAIN:

Tightening Torque

MAIN - (1) #18-1/0 AWG

MAIN - (1) #14-2/0 AWG

MAIN - (1) #6-250 MCM

BRANCH - (1) #18-1/0 AWG

BRANCH - (4) #14-#4 AWG

BRANCH - (1) #6-250 MCM

MAIN

MAIN

MAIN

#6-2/0 / 120 lbf-in / (13.5 N-m) #3-1/0 / 50 lbf-in /(5.6 N-m)

#6-2/0

120 lbf-in (13.5 N-m) #6-250 MCM /

#8 / 40 lbf-in (4.5 N-m)

#6-#4 / 45 lbf-in / (5.1 N-m)

#8

40 lbf-in (4.5 N-m)

#14-#10 / 35 lbf-in (4.0 N-m)

#8 / 40 lbf-in / (4.5 N-m)

#14-#10 35 lbf-in (4.0 N-m)

375 lbf-in (42.3 N-m)

#18-#10 / 35 lbf-in / (4.0 N-m)
BRANCH

BRANCH

BRANCH

#14-#4 / 35 lbf-in / (4.0 N-m)

#3-1/0 / 50 lbf-in / (5.6 N-m)

#14-#4

BRANCH
35 lbf-in (4.0 N-m)

#6-250 MCM /

#6-#4 / 45 lbf-in / (5.1 N-m)

375 lbf-in (42.3 N-m)

#8 / 40 lbf-in / (4.5 N-m)
#18-#10 / 35 lbf-in / (4.0 N-m)
Lug Material

Tin Plated High Conductive AL Tin Plated High Conductive CU Tin Plated High Conductive CU Tin Plated High Conductive CU

Base Material

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

Temperature Rating

-40 to 302° F
-40 to 150° C

-40 to 302° F
-40 to 150° C

-40 to 302° F
-40 to 150° C

-40 to 302° F
-40 to 150° C

Certifications

File E60616 Guide XCFR2

Flammability Rating

UL94V-0

Block Catalog Number

N/A

Clear Plastic covers

N/A
N/A

¨

File 70361 / Class 6228-01

UL94V-0

RoHS Compliant

Marked

UL94V-0

UL94V-0

9080LBC162101

9080LBC162104

9080LBC163101

9080LB21

9080LB21

9080LB31

1.78 x 2.88 x 1.13 in.
45.2 x 73.2 x 28.7 mm

1.78 x 2.88 x 1.13 in.
45.2 x 73.2 x 28.7 mm

2.61 x 4.00 x 1.94 in.
66.3 x 101.6 x 49.3 mm

One Pole Blocks

Block Dimensions
(D) x (H) x (W)

Two Pole Blocks
Block Catalog Number

N/A

N/A

9080LBC262104

N/A

Clear Plastic covers

N/A

N/A

9080LB22

N/A

Block Dimensions
(D) x (H) x (W)

N/A

N/A

1.78 x 2.88 x 1.94 in.
45.2 x 73.2 x 49.3 mm

N/A

Three Pole Blocks
Block Catalog Number

9080LBA362106

9080LBC362101

9080LBC362104

9080LBC363101

Clear Plastic covers

9080LB23

9080LB23

9080LB23

9080LB33

Block Dimensions
(D) x (H) x (W)

2.10 x 2.90 x 5.38 in.
53.3 x 73.7 x 136.7 mm

1.78 x 2.88 x 2.75 in.
45.2 x 73.2 x 69.9 mm

1.78 x 2.88 x 2.75 in.
45.2 x 73.2 x 69.9 mm

2.61 x 4.00 x 5.00 in.
66.3 x 101.6 x 127.0 mm

9080FBDIN3

N/A

N/A

N/A

DIN 3 (35 mm) Track Adapter

10
04/2009

© 1993 - 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
9080LBC Power Distribution Blocks Copper Wire Only
Class 9080

Standard

Maximum Voltage Rating

600

600

600

Service Class

C

C

C

C

Amperage Rating-CU Wire

380 amp.

350 amp.

760 amp.

760 amp.

Amperage Rating-AL Wire

N/A

N/A

N/A

N/A

SCCR w/Circuit Breakers

N/A

See page 28

N/A

N/A

SCCR with Fuses

See page 30

See page 30

See page 30

See page 30

Wire Range
Lugs suitable for use with
75° C Conductors.

MAIN

MAIN

(1) #4 - 500 MCM
BRANCH

BRANCH

(6) #14-2 AWG
MAIN
#4-500 MCM 375 lbf-in (42.3 N-m)
BRANCH

Tightening Torque

MAIN

(2) #14 - 2/0 AWG

#3-#2

50 lbf-in (5.6 N-m)

#6-#4

45 lbf-in (5.1 N-m)

#8

40 lbf-in (4.5 N-m)

#14-#10

35 lbf-in (4.0 N-m)

MAIN

(2) #4 - 500 MCM
BRANCH

(6) #14 - #4 AWG

#6-2/0

120 lbf-in (13.5 N-m)

#8

40 lbf-in (4.5 N-m)

#14-#10

35 lbf-in (4.0 N-m)

BRANCH
#14-#4

35 lbf-in (4.0 N-m)

(2) #4 - 500 MCM
BRANCH

(8) #14 - 2/0 AWG
MAIN

MAIN

600

(12) #14-2 AWG
MAIN

#4-500 MCM -

#4-500 MCM -

375 lbf-in (42.3 N-m)
BRANCH
#6-2/0

375 lbf-in (42.3 N-m)
BRANCH

120 lbf-in (13.5 N-m)

#3-#2

#8

40 lbf-in (4.5 N-m)

#6-#4

50 lbf-in (5.6 N-m)
45 lbf-in (5.1 N-m)

#14-#10

35 lbf-in (4.0 N-m)

#8

40 lbf-in (4.5 N-m)

#14-#10 35 lbf-in (4.0 N-m)
Tin Plated High

Tin Plated High

Tin Plated High

Conductive CU

Conductive CU

Conductive CU

Conductive CU

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

General Purpose Phenolic

Lug Material
Base Material
Temperature Rating

-40 to 302° F

-40 to 302° F

-40 to 302° F

-40 to 302° F

-40 to 150° C

-40 to 150° C

-40 to 150° C

-40 to 150° C

File E60616 Guide XCFR2

Certifications
Flammability Rating

Tin Plated High

UL94V-0

¨

File 70361 / Class 6228-01

UL94V-0

RoHS Compliant

Marked

UL94V-0

UL94V-0
9080LBC165212

One Pole Blocks
Block Catalog Number

9080LBC163106

9080LBC163206

9080LBC165208

Clear Plastic covers

9080LB31

9080LB31

9080LB51

9080LB51

Block Dimensions

2.61 x 4.00 x 1.94 in.

2.61 x 4.00 x 1.94 in.

3.12 x 5.50 x 3.17 in.

3.12 x 5.50 x 3.17 in.

(D) x (H) x (W)

66.3 x 101.6 x 49.3 mm

66.3 x 101.6 x 49.3 mm

79.2 x 139.7 x 80.5 mm

79.2 x 139.7 x 80.5 mm

Two Pole Blocks
Block Catalog Number

9080LBC263106

9080LBC263206

N/A

N/A

Clear Plastic covers

9080LB32

9080LB32

N/A

N/A

N/A

N/A

Block Dimensions

2.61 x 4.00 x 3.47 in.

2.61 x 4.00 x 3.47 in.

(D) x (H) x (W)

66.3 x 101.6 x 88.1 mm

66.3 x 101.6 x 88.1 mm

Block Catalog Number

9080LBC363106

9080LBC363206

9080LBC365208

9080LBC365212

Clear Plastic covers

9080LB33

9080LB33

9080LB53

9080LB53

Three Pole Blocks

Block Dimensions

2.61 x 4.00 x 5.00 in.

2.61 x 4.00 x 5.00 in.

3.12 x 5.50 x 8.54 in.

3.12 x 5.50 x 8.54 in.

(D) x (H) x (W)

66.3 x 101.6 x 127.0 mm

66.3 x 101.6 x 127.0 mm

79.2 x 139.7 x 216.9 mm

79.2 x 139.7 x 216.9 mm

© 1993 - 2009 Schneider Electric
All Rights Reserved

11
04/2009

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
9080LBA and 9080LBC Power Distribution Block Approximate Dimensions
9080LBA/9080LBC9080LBa/LBC

A2

A1

A3

J- Mounting Hole Dia.

B

G

D

E

D

E

E

F

D

C
H

A1

A2

A3

B

C

D

E

F

G

H

J

LBA161101
LBA161104

1 Pole

N/A
LBA261104

2 Pole

LBA361101
LBA361104

3 Pole

0.76

1.40

2.03

2.29

1.53

0.38

0.64

0.19

1.93

0.32

0.201

LAB162101
LBA162104
LBC162101
LBC162104

LBA262101
LBA262104
N/A
LBC262104

LBA362101
LBA362104
LBC362101
LBC362104

1.13

1.94

2.75

2.88

1.78

0.56

0.81

0.31

2.25

0.24

0.205

LBA163101
LBA163104
LBA163106
LBA163206
LBC163101
LBC163106
LBC163206

LBA263101
LBA263104
LBA263106
LBA263206
N/A
LBC263106
LBC263206

LBA363101
LBA363104
LBA363106
LBA363206
LBC363101
LBC363106
LBC363206

1.94

3.47

5.00

4.00

2.61

0.97

1.53

0.31

3.38

0.40

0.203

LBA164101
LBA164108

N/A
LBA264108

LBA364101
LBA364108

2.28

4.16

6.04

4.75

2.92

1.14

1.88

0.31

4.13

0.51

0.200

LBA165202
LBA1652021
LBA165106
LBA165112
LBA165212
LBC165208
LBC165212

LBA265202
LBA2652021
LBA265106
LBA265112
LBA265212
N/A
N/A

LBA365202
LBA3652021
LBA365106
LBA365112
LBA365212
LBC365208
LBC365212

3.17

5.85

8.54

5.50

3.12

1.58

2.69

0.38

4.75

0.50

0.265

USE A #8 SELF TAPPING SCREW
FOR MOUNTING COMPONENT

.218 x .375
[5.5 x 9.5]
SLOT
.265 x .375
[6.7 x 9.5]
SLOT

.50
13

1.00
25.4

1.45
36.8
4.63
117.5

2.90
73.7

1.07
27

4.77
121

.50
13

5.37
136.4

.60
15.2

2.06
52.3

DIN Rail Adapter

.38
9.5

Dimensions:

in.
[mm]

LBA362106

20
04/2009

© 1993 - 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
UL Short Circuit Current Ratings
Table 3:

9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Circuit Breakers

Cat No.

Suitable Conductors MCM / AWG
CU
Line

Load

Overcurrent Protection Circuit Breaker
Required
Mfr.

Type

Max A

SCCR, RMS
Sym A

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

9080LBA161101

JLL36250

250

65 kA

9080LBA361101

HDL36100

100

18 kA

2-6

8-10

2 -6

8-10

Square D

Square D

9080LBA161104
9080LBA261104

8- 10

(4) 14

Square D

9080LBA361104

9080LBA362106

2/0 -6

(6) 4- 10

Square D

9080LBA165106
9080LBA265106

2/0 -4

6) 8

Square D

9080LBA365106

9080LBA165112
9080LBA265112

2/0 -4

12) 2 -8

Square D

9080LBA365112

9080LBA164108
9080LBA264108

2/0 -6

6) 2 - 10

Square D

9080LBA364108

9080LBA163104
9080LBA263104

2/0 -4

9080LBA363104

© 1993 - 2009 Schneider Electric
All Rights Reserved

4) 2 -8

Square D

HGL36100

100

35 kA

HJL36100

100

65 kA

HLL36100

100

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

HDL36100

100

18 kA

HGL36100

100

35 kA

HJL36100

100

65 kA

HLL36100

100

65 kA
18 kA

JDL36250

250

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

Volts Max

480

480

480

480

480

480

480

27
04/2009

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
UL Short Circuit Current Ratings
Table 3:

9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Circuit Breakers
(continued)

Cat No.

Suitable Conductors MCM / AWG
CU
Line

Load

Overcurrent Protection Circuit Breaker
Required
Mfr.

9080LBA163206
9080LBA263206

2) 1/0 -8

6) 4- 10

Square D

9080LBA363206

2) 2/0 -2

6) 4-8

Square D

9080LBC163206
9080LBC263206
9080LBC363206
2) 4-6

9080LBC162101
9080LBC362101

1/0 -8

6) 10-12

1/0 -8

Square D

Square D

9080LBA163106
9080LBA263106

2/0 -6

6) 2 - 10

Square D

9080LBA363106

9080LBA162104
9080LBA262104

2/0 - 10

4) 4- 10

Square D

9080LBA362104

9080LBC162104
9080LBC262104
9080LBC362104

2/0 -8

4) 4-8

Square D

Type

Max A

SCCR, RMS
Sym A

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36175

175

18 kA

JGL36175

175

35 kA

JJL36175

175

65 kA

JLL36175

175

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

JGL36250

250

35 kA

JJL36250

250

65 kA

JLL36250

250

65 kA

JDL36250

250

18 kA

Volts Max

480

480

480

480

480

480

28
04/2009

© 1993 - 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
UL Short Circuit Current Ratings
Table 4:

9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Fuses
Suitable Conductors
MCM / AWG CU

Catalog Number
1 Pole

2 Pole

3 Pole

9080LBA161101

N/A

9080LBA361101

9080LBA161104

9080LBA261104

9080LBA361104

9080LBA162101

9080LBA262101

9080LBA162104

Line

Fuse Type / Amperage

Load

J

T

RK1

RK5

G

CC

SCCR

Volts
Max

2-6

2-6

200

200

200

100

60

30

100 kA

600

8-10

8-10

100

100

100

–

60

30

100 kA

600

2-6

10-14

200

200

200

100

60

30

200 kA

600

8-10

10-14

100

100

100

30

60

30

100 kA

600

9080LBA362101

2/0-6

2/0-6

300

300

200

100

60

30

65 kA

600

9080LBA262104

9080LBA362104

2/0-6

4-14

200

200

200

100

60

30

100 kA

600

N/A

N/A

9080LBA362106

2/0-6

4-14

9080LBA163101

9080LBA263101

9080LBA363101

9080LBA163104

9080LBA263104

9080LBA363104

9080LBA163106

9080LBA263106

9080LBA363206

9080LBA164101

N/A

9080LBA364101

9080LBA164108

9080LBA264108

9080LBA364108

9080LBA165202

9080LBA265202

9080LBA1652021

–

–

60

–

100 kA

600

200

100

–

30

200 kA

600

400-3/0

2-8

400

400

400

100

60

30

100 kA

600

2/0-6

2-14

200

200

200

100

60

30

100 kA

600

400-3/0

2-8

400

400

400

200

–

30

200 kA

600

600

–

–

–

60

–

100 kA

600

200

200

200

100

–

30

200 kA

600

–

–

–

–

60

–

100 kA

600

2/0-6

9080LBA263206

–
200

N/A

9080LBA363106

9080LBA163206

–
200

2-14

(2)2/0-2

4-8

400

400

400

100

60

30

100 kA

600

(2)4-6

10-14

300

300

200

100

60

30

100 kA

600

600-2

600-2

600

600

–

–

–

–

50 kA

600

400

400

400

200

60

30

100 kA

600

400-3/0

2-8

400

400

400

200

60

30

100 kA

600

2/0-6

2-14

200

200

200

100

60

30

100 kA

600

9080LBA365202

(2)350-4

(2)350-4

450

450

400

200

60

30

100 kA

600

600

600

–

–

–

–

50 kA

600

9080LBA2652021

9080LBA3652021

(2)500-4

(2)500-4

600

600

400

200

60

30

100 kA

600

9080LBA165106

9080LBA265106

9080LBA365106

500-3/0

2/0-6

400

400

400

100

60

30

100 kA

600

2/0-4

8-14

200

200

200

100

60

30

100 kA

600

9080LBA165112

9080LBA265112

9080LBA365112

500-3/0

2-8

400

400

400

200

60

30

100 kA

600

2/0-4

2-14

200

200

200

100

60

30

100 kA

600

(2)500-250

2/0-4

600

9080LBA165208

9080LBA265208

9080LBA365208

© 1993 - 2009 Schneider Electric
All Rights Reserved

(2)4/0-4

2/0-10

600

600

400

200

60

30

100 kA

600

600

–

–

–

–

50 kA

600

400

400

400

200

60

30

100 kA

600

29
04/2009

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Terminal Blocks
UL Short Circuit Current Ratings
Table 4:

9080LBA and 9080LBC Power Distribution Blocks Short Circuit Current Ratings with Fuses (continued)
Suitable Conductors
MCM / AWG CU

Catalog Number
1 Pole

9080LBA165212

2 Pole

9080LBA265212

3 Pole

Line

Load

(2)500-250

4-8

9080LBA365212
(2)4/0-4

9080LBC162101

N/A

9080LBC362101

9080LBC162104

9080LBC262104

9080LBC362104

9080LBC163101

N/A

9080LBC363101

9080LBC163106

9080LBC263106

9080LBC363106

9080LBC163206

9080LBC263206

9080LBC363206

9080LBC165208

N/A

9080LBC365208

9080LBC165212

N/A

4-14

Fuse Type / Amperage
J

T

RK1

RK5

G

CC

SCCR

Volts
Max
600

600

600

600

N/A

N/A

N/A

50 kA

400

400

400

200

60

30

100 kA

600

600

600

N/A

N/A

N/A

N/A

50 kA

600

400

400

400

200

60

30

100 kA

600

100

60

30

100 kA

600

N/A
2/0-6

4-14

200

200

200
N/A

500-3/0

2-8

400

400

400

200

60

30

100 kA

600

2/0-4

2-14

200

200

200

100

60

30

100 kA

600

(2)2/0-2

4-8

400

400

400

100

60

30

100 kA

600

(2)4-6

10-14

200

200

200

100

60

30

100 kA

600

(2)500-250

2/0-4

(2)4/0-4

2/0-6

(2)500-250

2-8

9080LBC365212
(2)4/0-4

2-14

600

600

400

200

60

30

100 kA

600

600

600

N/A

N/A

N/A

N/A

50 kA

600

400

400

400

200

60

30

100 kA

600

600

600

600

–

–

–

50 kA

600

400

400

400

200

60

30

100 kA

600

600

600

–

–

–

–

50 kA

600

400

400

400

200

60

30

100 kA

600

30
04/2009

© 1993 - 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : MRAI46
Create Date                     : 2009:05:06 14:01:35-07:00
Modify Date                     : 2009:05:06 14:17:47-07:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Metadata Date                   : 2009:05:06 14:17:47-07:00
Creator Tool                    : PScript5.dll Version 5.2
Format                          : application/pdf
Title                           : Schneider Electric/Square D Terminal Blocks - Fuseholders and Power Distribution Blocks
Creator                         : MRAI46
Document ID                     : uuid:fcab38b1-9558-ce40-8def-8cb9b6865695
Instance ID                     : uuid:2ae2f506-1151-8f46-a738-ff3d9e14beba
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Page Count                      : 11
EXIF Metadata provided by EXIF.tools

Navigation menu