Table of Contents

Section 9
Panelboards

NQ
NF
I-Line™

9-2, 9-42
9-3
9-3

Lighting and Appliance Panelboards
NQ/NF
NQ

NQ Panelboards
Page 9-5

NF Panelboards
Page 9-13

Pricing Procedure
Merchandised Main Lug Panelboards
Merchandised Main Circuit Breaker Panelboards
Merchandised 14-inch-wide Panelboards
Merchandised Accessories
QOB Branch Circuit Breakers
Factory Assembled Panelboards and Circuit Breakers
Factory Assembled Common Features
NF
Merchandised Main Lugs Panelboards
Merchandised Main Circuit Breaker Panelboards
Merchandised Main Lug and Main Circuit Breaker Panelboards with
Merchandised Accessories
EDB, EGB, EJB Branch Circuit Breakers
Factory Assembled Panelboards
Factory Assembled Common Features
NQ/NF
Merchandised Single Row (Column Width) Panelboards
Column Width Factory Assembled Single Row (Column Width) Panelboards

9-5
9-6
9-7
9-8
9-9
9-10
9-11
9-12
9-13
9-13
9-13
9-14
9-15
9-16
9-17
9-18
9-19

Power Distribution Panelboards—Circuit Breaker Type
I-Line/QMB
I-Line

I-Line Panelboards
Page 9-20

Pricing Procedure
Merchandised Panelboards (HCN, HCM, HCP-SU)
Merchandised Panelboards (HCP, HCR-U)
Merchandised Accessories
Circuit Breakers
F-frame Circuit Breakers
Q-frame Circuit Breakers
H-frame and J-frame Circuit Breakers
K-frame Circuit Breakers
L-frame Circuit Breakers
M-frame Circuit Breakers
P-frame and R-frame Circuit Breakers
Factory Assembled Pricing
Factory Assembled Branch Circuit Breakers
Factory Assembled Common Features

9-20
9-21
9-22
9-23
9-24
9-24
9-25
9-26
9-27
9-28
9-29
9-30
9-31
9-32
9-34

Power Distribution Panelboards—Fusible Type
QMB

Replacement Switches
Factory Assembled Pricing
Factory Assembled SPD Units

9-35
9-36
9-37

Panelboard Special Features

QMB Panelboards
Page 9-35

© 2012 Schneider Electric
All Rights Reserved

Factory Assembled Modifications
Terminal Data

9-38
9-39

9-1

9

Series Rated / Fully Rated Tables

PANELBOARDS

,x

Series Ratings

NQ Panelboards
Class 1640
www.schneider-electric.us

9

This page contains UL Tested and Certified series combination ratings for
panelboards. These ratings apply to either an integral main located in the
same enclosure or a remote main located in a separate enclosure.
Table 9.1:

NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)

PANELBOARDS

Square D™ Brand
Maximum Maximum
Short
Integral or Remote
System
Circuit Main Circuit Breakers
Voltage Current
and Remote Main
AC ab
Rating
Fuses

Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef
Type

1 Pole

2 Pole

3 Pole

NOTE: Table 9.1 NQ Series Connected Circuit Breaker Ratings
table has moved to page 9-42 and page 9-43.

9-2

© 2012 Schneider Electric
All Rights Reserved

Series Ratings

NF and I-Line™ Panelboards
Class 2110 / Refer to Catalog 2110CT9701

Table 9.2:

NF Series Connected Circuit Breaker Ratings (RMS Symmetrical)

Max.
Maximum Short
System Circuit
Voltage, Current
AC a Rating

Square D™ Brand
Integral or Remote
Main Circuit Breakers and
Remote Main Fuses

Square D™ Brand
Branch Circuit Breaker Catalog
Designation and Allowable
Ampere Ranges

EG, FH, FG, KH, LH, MH, MX, HG, JG, DG
LG
EG
EJ, FC, FJ, KC, LC, HJ, JJ
120
100,000
DJ, LJ
120/240
EJ, FC, KC, HJ, JJ
240
125,000
HL, JL
FI, KI, LI, LXI, HR, JR, LR
200,000
FI, KI, HR, JR
Class J or T (600 V) 200 A Max Fuses
EG, FG, KH, LH, HG, JG, DG, LG
35,000
EG, HG, JG
EJ, FC, FJ, KC, LC, LX, HJ, JJ, DJ
EJ, FC, KC, HJ, JJ
65,000
LJ
65,000

277
480Y/277
100,000
200,000
18,000
25,000
600Y/347 35,000
50,000
65,000
200,000

EDB, EDB-EPD
EDB
ECB-G3
EDB, EDB-EPD, EGB
EDB, EGB
ECB-G3
EDB, EDB-EPD, EGB, ECB-G3
EDB, EDB-EPD, EGB, EJB
ECB-G3
ECB-G3
EDB, EDB-EPD
ECB-G3
EDB, EDB-EPD, EGB
ECB-G3
EDB, EDB-EPD, EGB,
EGB-EPD
LL
EDB-EPD, EGB-EPD
HL, JL
EDB, EDB-EPD, EGB, EJB
DL, LL
EDB, EGB, EJB
400 A Max Fuses
EDB, EDB-EPD, EGB, EJB
FI, KI, LI, LXI, HR, JR, LR
EDB, EDB-EPD, EGB, EJB
FI, KI, HR, JR
ECB-G3
200 A Max Fuses
EDB, EDB-EPD, EGB, EJB, ECB-G3
HG, JG, MG,
EDB
LG
EDB (15–110 A)
EJ, FI, KH, KI, LC, LE, LX, LI, LXI, HJ, JJ
EDB, EGB
EDB (15–110 A),
LJ
EGB (15–110 A)
LH
(15–70 A) EDB, EGB
LC, LE, LX
EDB, EGB, EJB
HL, JL,
EDB, EGB, EJB
EDB
(15–110 A), EGB
LL
(15–110 A),EJB (15–110 A)
FI, KI, HR, JR
EDB, EGB, EJB
LI, LXI, LR
EJB
Class J or T (600 V) 200 A Max Fuses
EDB, EGB, EJB

.

Table 9.3:

I-Line Series Connected Circuit Breaker Ratings
(RMS Symmetrical)

Max. Short
Square D™ Brand Branch Circuit Breakers
Maximum Circuit
Integral or Remote
System Current
2- or 3-pole Main
Voltage
Rating
Designation
Poles
Circuit Breaker
AC a
(RMS
Symm.)
42k
MG
FY
65k
QG, LH
FA, FDb
FJb,
QJ
FDb
120
1
100k
QJ, LC
FA
LJ
FH
200k
LR
FH, FY
QJ
FA, FDb
208Y/120
100k
2, 3
QJ, PH, PJ, RJ
QD, QG
35k
MG
FA
1
KA
FDb
1, 2, 3
42k
LA, MA
HD, JD, QD
2, 3
MG
FA
50k
MG
FA (25 A Max.)
1
HG, JG
FA, HD
JG
JD, QD
2, 3
QG
FA, FDb, QD
LH, MH, PA, PG, RG
HD, JD, QD
FGb, FH, MH, MX, PJ
FDb
65k
FC, KC, KH, LC, LH
FDb, FGb
1, 2, 3
LH
FA
LH
LA
MG
HD, JD, KA
LG
HD, JD, KA, LA, LD, MA
2, 3
DG
FH, HD, JD, KA, LA, MA
85k
RL
FH, KH
240
FC, KC, LC, LX
FDb, FGb, FJ
1
PH, PJ, RJ
QD, QG
2, 3
QJ
FDb
2
FJb
FDb
FC, KC
FA, FH, FDb, FGb, FJb
LC, LX
FH, FDb, FGb, FJb
2, 3
KC, LC, LX
KA
KC, LC
KH
LC
LA, LH, MG
100k
LC
FA
1, 2, 3
HJ, JJ
FA, FH, HD, HG
JJ
JD, JG
LC, LX, MJ, PJ, RJ
HD, HG, JD, JG
MJ
LA, LH
LJ
FH, HD, HG, JD, JG, KA, LA, LD, LG, MA, MG 2, 3
DJ
FH, HD, HG, JD, JG, KA, LA, MA, MG
RL
RG
HL, JL
HD, HG, HJ, FA, H
JL
JD, JG, JJ
PC, PH, PL, RL
HD, HG, JD, JG
240
125k
PC, PL, RL
HH, JJ
2, 3
FI, KI, LI, LXI
HD, HG, HJ
KI, LI, LXI
JD, JG, JJ

Table 9.3:

I-Line Series Connected Circuit Breaker Ratings
(RMS Symmetrical) (continued)

Max. Short
Square D™ Brand Branch Circuit Breakers
Maximum Circuit
Integral or Remote
System Current
2- or 3-pole Main
Voltage
Rating
Designation
Poles
Circuit Breaker
AC a
(RMS
Symm.)
FI, KI, LI, LXI
FDb, FGb, FJ
1
FI, KI
FA, FH, FC, FDb, FGb, FJb
LI, LXI
FH, FDb, FGb, FJb
240
200k
LI
FC
2, 3
KI, LI, LXI
KA, QD, QG, QJ
LI
KC
LR
FH, HJ, HL, JJ, JL, LA, LH, QD, QG, QJ
18k
LD
FY
25k
FH, KA
FDb
FGb, KH, LH
FDb
35k
DG
FH, FY
LG
FH, FY
FJb
FDb
FC, KC
FA, FH, FY, FDb, FGb
LC, LX (400 A Max.)
FH
65k
LC, LX (600 A Max.)
FY, FDb, FGb
LJ
FH, FY
277
1
DJ
FH, FY
LL
FY
DL
FH, FJb
100k
LL
FH, FJb
FI, KI
FA, FH, FY, FDb, FGb, FJb
HR
FA, FJb, FY
JR
FA, FJb, FY
200k
LI, LXI (400 A Max.)
FH
LI, LXI (600 A Max.)
FY, FDb, FGb, FJb
LR
FH, FY
22k
MG
FA
KH, LA, MA, MX, PA,
FH
PC, PX, PJ
30k
LA, MA, PA, PC, PX
KA
LA, MA, PA
HD, JD
MG
FA (25 A Max.), FH, KA
MH, MX, PA
HD, JD
HG, JG
FA, HD
JG
JD
35k
LH, MG, PG, RG
HD, JD
LG
FH, HD, JD, KA, LA, LD, MA
DG
FH, HD, JD, KA, LA, MA
MJ
FH (25 A Max.)
42k
RL
RG
50k
MJ
KA, KH
FC, KC
FA, FH
HJ, JJ
FA, FH, HD, HG
JJ
JD, JG
LC, LI, LX, LXI
HD, HG, JD, JG
65k
LC,
LX
(400
A
Max.)
FH
480
KC, LC, LX
KA
LC, LX
LA
LJ
FH, HD, HG, JD, JG, KA, LA, LD, LG, MA
2, 3
DJ
FH, HD, HG, JD, JG, KA, LA, MA
HL, JL
FA, FH, HD, HG, HJ
JL
JD, JG, JJ
JR
FA
LI, LXI (600 A Max.)
KA
100k
FH,
HD,
HG,
HJ,
JD,
JG, JJ, KA, LA, LD, LG,
LL
LJ, MA
DL
FH, HD, HG, HJ, JD, JG, JJ, KA, LA, MA
PC, PH, PL, RL
HJ, JJ
RL
RG
FI, KI
FA, FH, FC, HD, HG, HJ
HR
FA, HD, HG, HJ, HL
JR
HD, HG, HJ, HL, JD, JG, JJ, JL
200k
KI
JD, JG, JJ, KA
LI
FC, KA, KC, LA, HJ, HL, JJ, JL
LR
FH, HJ, HL, JJ, JL, LA, LH
LXI
KA, HJ, HL, JJ, JL
25k
FH, KA
FDb
35k
FGb, KH, LH
FDb
FJb
FDb
480Y/277
65k
FC, KC
FDb, FGb
LC, LX (600 A Max.)
FDb, FGb
FI, KI
FDb, FGb, FJb
200k
LI, LXI (600 A Max.)
FDb, FGb, FJb
HG, JG
FA, HD
JG
JD
18k
LG
HD, JD, LD
MG, PG, RG
HD, JD
MG
FA
HJ, JJ
FA, HD, HG
JJ
JD
25k
LJ
HD, HG, JD, JG, LD, LG, MA
PJ, RJ
MG
35k
LC
FH, HD, HG, HJ, JD, JG, JJ, LA
600
2, 3
HL, JL
FA, HD, HG, HJ
JL
JD,
JG,
JJ
50k
LL
HD, HG, HJ, JD, JG, JJ, LD, LG, LJ, MA
PK
HJ, JJ, MJ
FI, KI
HD, HG, HJ
HR
FA, HD, HG, HJ, HL
JR
FA, HD, HG, HJ, HL, JD, JG, JJ, JL
100k
KI
JD, JG, JJ
KI, LI
FH
LI
LA
18k
MG
FA (25 A max.)
600Y/347
25k
MJ
FA (30 A max.)
1
50k
HL, JL
FJ
a
Short circuit tests are conducted at 100–105% of the maximum rated voltage of the
panelboard.
b
Obsolete. Contact your local Schneider Electric representative or distributor for the
replacement circuit breaker.

NOTE: LD, LG, LH, and LL breakers are only available in 3 pole
configurations.
© 2012 Schneider Electric
All Rights Reserved

9-3

PANELBOARDS

This page contains UL Tested and Certified series combination ratings for
panelboards. These ratings apply to either an integral main located in the
same enclosure or a remote main located in a separate enclosure.

9

www.schneider-electric.us

Series Ratings

I-Line™ Panelboards
Class 2110
www.schneider-electric.us

9

Table 9.4:

Fuse/I-Line Circuit Breaker Series Connected Ratings

Short Circuit
Maximum System Max.
Current Rating
Voltage AC
(RMS Symm.)

PANELBOARDS

120/240 1Ø
208Y/120

100,000

240

65,000

Remote Main Fuse
Maximum
Amperage
1200 A
800 A
600 A
1200 A
800 A
600 A
1200 A
800 A
600 A

240

100,000
800 A
1200 A
1600/2000 A
4000 A

Square D™ Brand Branch Circuit Breakers

Fuse Class

Designation a

L, T (300 V)
T (600 V)
J, RK5
L, T (300 V)
T (600 V)
J, RK5
L, T (300 V)
T (600 V)
J, RK5
L, T (600 V)
RK5
J
T (600 V)
T (300 V)
L
L
T (600 V)
L
L

QD, QG
QD, QG
QD, QG
QD
QD
QD
QD, QG (2-pole)
QD, QG (2-pole)
QD, QG (2-pole)
FA, FH, KA, KH, KC, LA, LH, MA, MH, MX, PG
FH, KA, KH, LA, LH, MA, MH, MX, PG, HD, HG, HJ, HL, JD, JG, JJ, JL
HD, HG, HJ, HL, JD, JG, JJ, JL
FH, KA, KH, LA, LH, MA, MH, MX, PG
PG
FH,KA,KH,LA,LH,MA,MH,MX,PG
FH, KH, LA, LH, MA, MH, MX, PG
HD, HG, HJ, HL, JD, JG, JJ, JL
KH, MA, MH, MX, PG
HD, HG, HJ, HL, JD, JG, JJ, JL
FA( 3-pole only), FH, FC, KA, KH, KC, LA, LH, LC,
MA, MH, MX, NA, NC, NX, PG, PJ, PL
FH, FC, HD, HG, HJ, HL, JD, JG, JJ, JL KH, KC, LA, LH, LC,
MA, MH, MX, NC, NX, PG, PJ, PL
HD, HG, HJ, HL, JD, JG, JJ, JL
FH, FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
PG, PJ, PL
FH,FC, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
FC, KH, KC, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
HD, HG, HJ, HL, JD, JG, JJ, JL
NA, NC, NX, PJ, PL
HD, HG, HJ, HL, JD, JG, JJ, JL
HD, HG, HJ, HL, JD, JG, JJ, JL
HJ, HL, JJ, JL
FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
FC, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
HJ, HL, JJ, JL
KC, LC, MA, MH, MX, NA, PG, PJ
KC, LC, MH,MG, MJ, MX, NA, PG, PJ
HJ, HL, JJ, JL
HJ, HL
FA, FH, FC, HJ, HL, JJ, JL, KA, KH, KC, LA, LH, LC,
MA, MH, MX, NA, NC, NX, PG, PJ, PL
FA, FH, FC, HJ, HL, JJ, JL, KA, KH, KC, LA, LH, MA, MH, MX, NA, NC, NX
FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL
KA, KH, KC, LA, LH, MA, MH, MX, NA, NC, NX
KC, LA, LH, LC, MA, MH, MX, MG, MJ, NC, NX, PG, PJ,
PG, PJ, PL
KA, KH, KC, LA, LH, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL
KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
KC, LC, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL
NA, NC, NX
HG, JG ( molded case switches )
HD, HG, HJ, HL, JD, JG, JJ, JL
HJ, HL, JJ, JL
MG, MJ
MG, MJ
MG, MJ
MG, MJ

J, T (600 V)
600 A

240

200,000

800 A
1200 A
1600/2000 A
4000 A
400 A
600 A

480

100,000

800 A
1200 A
1600 A
2000 A
4000 A
200 A
400 A

480

200,000

600 A

800 A

a

600

100,000

600

200,000

1200 A
1600/2000 A
30 A
200 A
400 A
600 A
1200 A
600 A
800 A

RK5
J
T (600 V)
T (300 V)
L
L
T (600 V)
L
L
J, T (600 V)
J, RK5
J, T (600 V)
RK5
L, T (600 V)
L
T (600 V)
L
L
L
RK5
J
T(600V)
J
T (600V)
RK5
T (300 V)
T (600 V)
L
L
L
CC
J
J, T (600 V)
R
L
J
T (600 V)

Series rating valid for 2-pole or 3-pole circuit breakers.

Note:
• The fuse used in this UL test is an envelope (umbrella) fuse. This fuse is designed as a “worst case’’ fuse. Thus, no matter what manufacturer’s fuse is used,
the Square D™ brand circuit breaker is protected.
• The line side fused switch may be in a separate enclosure or in the same enclosure as the loadside circuit breaker. A line side fused switch may be a
submain, integral main, or remote main. A load side circuit breaker may be a branch, submain, or an integral main used on the load side of a remote main.
This series combination short circuit current rating shall not exceed that of the line side fused switch. The charts apply to Square D™ brand load side circuit
breakers only. However, the line side fuse ratings are independent of the fuse manufacturer.
• Not applicable to Corner Grounded Systems.
• Limiters used in Square D™ brand DSL and DSL II fused power circuit breakers are not class L fuses and do not have series ratings.

9-4

© 2012 Schneider Electric
All Rights Reserved

NQ and NF Panelboards

Pricing Procedure and Examples

www.schneider-electric.us

NQ and NF Factory Assembled Pricing Procedure

1.

List circuit breakers required, either plug-on or bolt-on. See the
appropriate Digest pages for catalog numbers.

1.

Select Base Price for main lugs or main circuit breaker from the Base
Price Table. Include equipment ground bar when required.

2.

Determine equivalent number of pole spaces required.

2.

3.

Select proper main lug interior (from page 9-6) or main lug interior and
main circuit breaker adapter kit (from page 9-7) based on equivalent
number of poles and ampere rating. Interiors include solid neutral and
are field convertible to top-feed.

List Branch Circuit Breakers (either plug-on or bolt-on) and determine
total spaces required. Select price from the Branch Circuit Breakers
Table. Include space-only charge for future requirements.

3.

If total spaces required exceeds the maximum listed, price as two or
more panelboards and add price for sub-feed or feed-through lugs so
installer can cable between sections.

4.

Add price for special features from appropriate page. Contact your local
Schneider Electric representative or distributor for additional special
features.

5.

For complete price, add all prices. Order by description.

4.

Select enclosure from appropriate page.
Type 1—Select box and front catalog number corresponding to interior
catalog number.
Type 3R, 5, 12—Select enclosure. Interior trim kit for Type 3R, 5, 12 is
included with the enclosure.

5.

For complete price, add the component prices. Include panelboard
accessories.

6.

Apply appropriate discount schedule.

NOTE: Additional special price adders can be found in the
Supplemental and Obsolescence Digest, Section 4.
6.

Apply appropriate discount schedule.

NQ Merchandised Pricing Example

NQ Factory Assembled Pricing Example

Table 9.5:

Table 9.7:

208Y/120 Vac, 3Ø4W, 10 kA SCCR, 225 A, MLO, Type-1,
surface-mount, bolt-on, branch circuit breakers,
main sub-feed lugs

Branches

Page No.

Catalog Number

Spaces

(20) 20/1
two 40/2
two 30/3

9-10
9-10
9-10

(20) QOB120
two QOB240
two QOB330

20
4
6
Total 30

795.
177.
585.

225 A MLO Interior
Box
Cover
Sub-feed Lugs

9-6
9-6
9-6
9-6

NQ430L2
MH32
NC32S
NQSFL2

–
–
–
–

1215.
113.
527.
203.

Total Price

3615.

$ Price

208Y/120 Vac, 3Ø4W, 10 kA SCCR, 225 A, MLO, Type-1,
surface-mount, bolt-on, branch circuit breakers,
main sub-feed lugs
Item

Page No.

225 A MLO Base Price
(20) 20/1 Bolt-on
two 40/2 Bolt-on
two 30/3 Bolt-on
Sub-feed Lugs

9-11
9-11
9-11
9-11
9-12

928.
1360.
268.
704.
128.

Total Price

3388.

NF Merchandised Pricing Example

NF Factory Assembled Pricing Example

Table 9.6:

Table 9.8:

480Y/277 Vac, 3Ø4W, 25 kA SCCR, fully rated, copper bus, 100 A,
main circuit breaker, Type 1, flush-mount, bolt-on,
branch circuit breakers

Branches

Page No.

Catalog No.

Spaces

(13) 20/1
one 40/2
one 50/3

9-15
9-15
9-15

EGB14020
EGB24040
EGB34050

13
2
3
Total 18

3315.
776.
1131.

Main circuit breaker adapter kit
(less circuit breaker)
Main circuit breaker
125 A MLO Cu Bus Int.
Box
Cover

9-13

N150MH

–

780.

7-28
9-13
9-13
9-13

HGL36100
NF418L1C
MH38
NC38F

–
–
–
–

1701.
1838.
113.
549.

Total Price

10203.

© 2012 Schneider Electric
All Rights Reserved

9

NQ and NF Merchandised Pricing Procedure

Example pricing only

$ Price

480Y/277 Vac, 3Ø4W, 25 kA SCCR, fully rated, copper bus, 250 A,
main circuit breaker, Type 1, flush-mount, bolt-on,
branch circuit breakers
Item

Page No.

250 A Main Circuit Breaker Base Price
Copper bus adder
(13) 20/1
one 40/2
one 50/3

9-16
9-17
9-16
9-16
9-16

6180.
458.
4212.
746.
1264.

Total Price

12860.

$ Price

Discount
Schedule

PANELBOARDS

Classes 1640 and 1670 / Refer to Catalog 1670CT0701, 1640CT0801

$ Price

9-5

NQ Merchandised
Panelboards

NQ Main Lug Interiors—240 Vac, 48 Vdc
Class 1640 / Refer to Catalog 1640CT0801
www.schneider-electric.us

9

Table 9.9:

Pole
Spaces

Main Lug Interiors—Accepts plug-on and bolt-on circuit breakers

Mains
Rating

Total Price Interior
Front and Enclosure

Type 1

Type 3R,
5,12

Catalog No. a

Type 3R, 5, 12 Enclosure f

Type 1 Enclosure

Interior Only
(Order Branch Circuit
Breakers Separately)

Box
20 in. W x 5.75 in. D b

$Price

Catalog No.

$ Price

Mono-Flat™ Front c
Catalog No.

Enclosure
20 in. W x 6.5 in. D

Hinged Front

Catalog No.

Height
(In.)

PANELBOARDS

$ Price

Catalog No.

$ Price

$ Price

NC26 ( )

497.

NC26( )HR

620.

MH26WP

2192.

26

MH32

NC32 ( )

527.

NC32( )HR

657.

MH32WP

2204.

32

MH32

NC32 ( )

527.

NC32( )HR

657.

MH32WP

2204.

32

NC38 ( )

549.

NC38( )HR

687.

MH38WP

2216.

38

MH44

NC44 ( )

663.

NC44( )HR

830.

MH44WP

2603.

44

MH50

NC50 ( )

729.

NC50( )HR

912.

MH50WP

2609.

50

NC50V ( )

729.

NC50V( )HR

912.

MH50WP

2609.

50

20-inch-wide Cabinet g—Single Phase 3-Wire
18
100
30
30
42
225
72d
84d
30
400

42

1395.

2977.

NQ18L1

785.

1474.

3056.

NQ18L1C

864.

1585.

3149.

NQ30L1

945.

1675.

3239.

NQ30L1C

1035.

1744.

3308.

NQ30L2

1104.

1819.

3383.

NQ30L2C

1179.

2002.

3556.

NQ42L2

1340.

2080.

3634.

NQ42L2C

1418.

3073.

4900.

NQ72L2

2297.

3206.

5033.

NQ72L2C

2430.

3521

5288.

NQ84L2

2679.

3677.

5444.

NQ84L2C

2835.

2462.

4229.

NQ30L4

1620.

2579.

4346.

NQ30L4C

1737.

2620.

4387.

NQ42L4

1778.
1896.

2738.

4505.

NQ42L4C

84d

4853.

6534.

NQ84L4C

3792.

30

2705.

4548.

NQ30L6C

1863.

2861.

4704.

NQ42L6C

2019.

5099.

6873.

NQ84L6C

4038.

42

600

84d

MH26
113.

MH38
113.

MH50

113.

MH68

NC68V ( )

948.

NC68V( )HR

1185.

MH68WP

2742.

68

MH50

NC50V ( )

729.

NC50V( )HR

912.

MH62WPe

2685.

50/62

NC68V ( )

948.

NC68V( )HR

1185.

MH80WPe

2835.

68/80

NC26 ( )

497.

NC26( )HR

620.

MH26WP

2192.

26

MH32

NC32 ( )

527.

NC32( )HR

657.

MH32WP

2204.

32

MH32

NC32 ( )

527.

NC32( )HR

657.

MH32WP

2204.

32

NC38 ( )

549.

NC38( )HR

687.

MH38WP

2216.

38

MH44

NC44 ( )

663.

NC44( )HR

830.

MH44WP

2603.

44

MH50

NC50 ( )

729.

NC50( )HR

912.

MH50WP

2609.

50

MH50

NC50V ( )

729.

NC50V( )HR

912.

MH50WP

2609.

50

MH62

NC62V ( )

887.

NC62V( )HR

1109.

MH62WP

2685.

62

MH68

NC68V ( )

948.

NC68V( )HR

1185

MH68WP

2742.

68

NC50V ( )

729.

NC50V( )HR

912.

MH62WPe

2685.

50/62

NC68V ( )

948.

NC68V( )HR

1185.

MH80WPe

2835.

68/80

113.

MH68

20-inch-wide Cabinet g —Three Phase 4-Wire
18
100
30
30
42
54

225

72d
84d
30
42

400

72d

1486.

3068.

NQ418L1

876.

1561.

3143.

NQ418L1C

951.

1752.

3316.

NQ430L1

1112.

1831.

3395.

NQ430L1C

1191.

1855.

3419.

NQ430L2

1215.

1932.

3496.

NQ430L2C

1292.

2138.

3692.

NQ442L2

1476.

2213.

3767.

NQ442L2C

1551.

2559.

4113.

NQ454L2

1898.

2655.

4209.

NQ454L2C

1994.

3307.

5134.

NQ472L2

2531.

3436.

5263.

NQ472L2C

2660.

3794.

5561.

NQ484L2

2952.

3944.

5711.

NQ484L2C

3102.

2704.

4471.

NQ430L4

1862.

2822.

4589.

NQ430L4C

1980.

2854.

4621.

NQ442L4

2012.

2975.

4742.

NQ442L4C

2133.

4449.

6134.

NQ472L4

3449.

4657.

6342.

NQ472L4C

3657.

84d

5327.

7008.

NQ484L4C

4266.

30

2983.

4826.

NQ430L6C

2141.

3116.

4959.

NQ442L6C

2274.

5609.

7383.

NQ484L6C

4548.

42

600

84d
a
b
c
d
e
f
g

9-6

MH26
113.

MH38
113.

113.

MH50

113.

MH68

“C’’ suffix indicates copper bussing.
Embossed mounting holes add a 0.25-inch standoff to back of MH box.
Add “F” for flush mount, “S” for surface mount.
Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits.
When NEMA 3R, 5, or 12 enclosures are selected, an NQ12RDE kit should also be selected. See Table 9.19.
Enclosure includes trim kit.
For the NQ14-inch-wide panelboard offer, See Digest page 9-8.

PE1A

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

NQ Merchandised
Panelboards

NQ Main Circuit Breaker Interiors—240 Vac, 48 Vdc
Class 1640 / Refer to Catalog 1640CT0801

www.schneider-electric.us

Main Circuit Breaker Interiors—Will accept plug-on and bolt-on circuit breakers
Type 3R, 5, 12 Enclosure e
Enclosure
20 in. W x 6.5in. D Height
(In.)
Catalog $ Price
No.

20-inch-wide Cabinet h—Single Phase 3-Wire
16k
28k
18

1395.
100 1474.
backfed 1585.
1675.
100

30

100

30

225

42

225

72d

225

84d

225

30

400

42

400

84d

400

2977.

NQ18L1

785.

—

—

3056.

NQ18L1C

864.

—

—

MH26

113.

NC26 ( )

497. NC26( )HR

620. MH26WP

2192.

26

MH32

113.

NC32 ( )

527. NC32( )HR

657. MH32WP

2204.

32

MH38

113.

NC38 ( )

549. NC38( )HR

687. MH38WP

2216.

38

780.

MH44

113.

NC44 ( )

663. NC44( )HR

830. MH44WP

2603.

44

780.

MH44

113.

NC44 ( )

663. NC44( )HR

830. MH44WP

2603.

44

MH50

113.

NC50 ( )

729. NC50( )HR

912. MH50WP

2609.

50

MH56

113.

NC56 ( )

786. NC56( )HR

983. MH56WP

2652.

56

MH62

113.

NC62 ( )

887. NC62( )HR

1109. MH62WP

2685.

62

3149.

NQ30L1

945.

—

—

3239.

NQ30L1C

1035.

—

—

NQMB2HJ

780.

2227.

3781.

NQ18L1

785.

2306.

3860.

NQ18L1C

864.

2501.

4328.

NQ30L1

945.

2591.

4418.

NQ30L1C

1035.

2660.

4487.

NQ30L2

1104.

2735.

4562.

NQ30L2C

1179.

2962.

4729.

NQ42L2

3040.

4807.

NQ42L2C

HD, HG, HJ, HLl
100A maximum
NQMB2HJ

1340. NQMB2HJ
1418.

3976.

5729.

NQ72L2

2297.

4109.

5862.

NQ72L2C

2430.

4459.

6144.

NQ84L2

2679.

4615.

6300.

NQ84L2C

2835.

3400.

5085.

NQ30L4

1620.

3517.

5202.

NQ30L4C

1737.

3558.

5243.

NQ42L4

1778.

3676.

5361.

NQ42L4C

1896.

5686.

7407.

NQ84L4C

Select
QOB 2-pole or
QOB-VHi

HD, HG, HJ, HLl
780. or JD, JG, JJ, JL

NQMB2Q
NQMB2KI

QB,QD,QG,QJ
780.

KI

780.
NQMB4LA

780.

LA/LHm

MH62

113. NC62V ( )

887. NC62V( )HR

1109. MH62WP

2685.

62

NQMB4LA

780.

LA/LHm

MH62

113. NC62V ( )

887. NC62V( )HR

1109. MH62WP

2685.

62

3792. NQMB4LA

780.

LA/LHm

MH80

113. NC80V ( )

1001. NC80V( )HR

1245. MH80WP

2835.

80

MH26

113.

NC26 ( )

497. NC26( )HR

620. MH26WP

2192.

26

MH32

113.

NC32 ( )

527. NC32( )HR

657. MH32WP

2204.

32

MH38

113.

NC38 ( )

549. NC38( )HR

687. MH38WP

2216.

38

MH44

113.

NC44 ( )

663. NC44( )HR

830. MH44WP

2603.

44

MH44

113.

NC44 ( )

663. NC44( )HR

830. MH44WP

2603.

44

MH50

113.

NC50 ( )

729. NC50( )HR

912. MH50WP

2609.

50

MH56

113.

NC56 ( )

786. NC56( )HR

983. MH56WP

2652.

56

MH62

113.

NC62 ( )

887. NC62( )HR

1109. MH62WP

2685.

62

20-inch-wide Cabinet h—Three Phase 4-Wire
15k
27k

1395.
100 1474.
backfed 1585.
1675.

18
100
30
30
42
54

225

72d
84d
30
42
72d
84d
a
b
c
d
e
f
g
h
i
j
k
l
m

400

2977.

NQ418L1

785.

—

—

3056.

NQ418L1C

864.

—

—

3149.

NQ430L1

945.

—

—

3239.

NQ430L1C

1035.

—

—

2318.

3872.

NQ418L1

876.

2393.

3947.

NQ418L1C

951.

2668.

4495.

NQ430L1

1112.

2747.

4574.

NQ430L1C

1191.

2771.

4598.

NQ430L2

1215.

2848.

4675.

NQ430L2C

1292.

3098.

4865.

NQ442L2

1476.

3173.

4940.

NQ442L2C

1551.

3519.

5286.

NQ454L2

1898.

3615.

5382.

NQ454L2C

1994.

4210.

5963.

NQ472L2

4339.

6092.

NQ472L2C

4732.

6417.

NQ484L2

2952.

4882.

6567.

NQ484L2C

3102.

3642.

5327.

NQ430L4

1862.

3760.

5445.

NQ430L4C

1980.

3792.

5477.

NQ442L4

2012.

3913.

5598.

NQ442L4C

2133.

5314.

6986.

NQ472L4

3449.

5522.

7194.

NQ472L4C

3657.

6160.

7881.

NQ484L4C

NQMB2HJ

Select
QOB 3-pole or
QOB-VHj

HD, HG, HJ, HL
780. 100A maximum

780.

NQMB2HJ

780.

NQMB2Q

2531. NQMB2KI
2660.

HD, HG, HJ, HL or
JD, JG, JJ, JL
QB,QD,QG,QJ

780.

KI

780.

NQMB4LA

780.

LA/LHm

MH62

113. NC62V ( )

887. NC62V( )HR

1109. MH62WP

2685.

62

NQMB4LA

780.

LA/LHm

MH74

113. NC74V ( )

972. NC74V( )HR

1215. MH74WP

2757.

74

4266. NQMB4LA

780.

LA/LHm

MH80

113. NC80V ( )

1001. NC80V( )HR

1245. MH80WP

2835.

80

“C’’ suffix indicates copper bussing.
Embossed mounting holes add a 0.25 inch standoff to back of MH box.
Add “F” for flush mount, “S” for surface mount.
Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits.
Enclosure includes trim kit.
Select the appropriate main circuit breaker from the tables starting on Digest page 7-22 and add the circuit breaker price to the total price of the panelboard.
Circuit breaker interrupt ratings, See the tables starting on Digest page 7-22.
For the NQ14-inch-wide panelboard offer, See Digest page 9-8.
QOB2150VH takes four pole spaces; all other QOB two pole circuit breakers take two pole spaces.
QOB3110VH to QOB3150VH take six pole spaces; all other QOB three pole circuit breakers take three pole spaces.
Pole spaces shown are available for branch circuits, with spaces deducted for the back fed main breaker.
For single phase applications, order a 3-pole breaker. Example: HDL36100.
For 400A applications, order short handle circuit breaker (LAL36400MB).

© 2012 Schneider Electric
All Rights Reserved

PANELBOARDS

Total $ Price
Type 1 Enclosure
Interior Only
Interior, Front, (Order
Circuit Breaker Adapter Kit
Branch Circuit Main(Less
Box
and
Circuit
Breaker)
f
Box
Pole Mains
Breakers Separately)
Hinged Front
20 in. W x 5.75 in. D b Mono-Flat™ Front
Spaces Rating Adapter Kit f
3R,
Circuit Breaker
Catalog
Type 1 Type
$ Price Catalog No. $ Price
5, 12 Catalog No. a $ Price Catalog No. $ Price Frame Size g Catalog No. $ Price No. c

PE1A

Discount
Schedule

9-7

9

Table 9.10:

NQ Merchandised
Panelboards

NQ 14-inch-wide Panelboards
Class 1640
www.schneider-electric.us

9

NQ 14-inch-wide—240 Vac, 48 Vdc
14-inch-wide NQ panelboards are now available for those customers whose equipment space is limited. Developed with
customer input, Square D™ brand NQ panelboards are built to last, featuring innovations for ease of installation and durability.

Features
PANELBOARDS

•
•
•
•
•
•
•

240 Vac, 48 Vdc maximum
225 A maximum main circuit breaker or main lugs
60 A maximum branch circuit breakers
Visi-Trip™ indication on branch circuit breakers
10,000–65,000 A Short Circuit Current Rating (SCCR)
Interiors supplied with tin plated copper bus as standard
Interiors accept bolt-on and plug-on branch circuit breakers

Table 9.11:

14-inch-wide NQ
Panelboard Main Lug

•

Three-phase, four-wire, and single-phase, three-wire
interiors available
Panelboards available with Mono-Flat™ front
Suitable for use as service entrance equipment
Branch circuit filler plates provide fast and easy
installation
Both fully and series-rated systems are available

•
•
•
•

Main Lug Interiors—Accepts Plug-On and Bolt-On Branch Breakers

Max. Number
of Breakers

Main
Ratings

Total $ Price
Interior, Front, Box
and Adapter Kit
Type 1

Interior Only (Order
Branch Circuit Breakers
Seperately)

Type 3R,
5, 12

Cat. No.

$ Price

Type 1 Enclosure
Box 14"W x 5.75" Db
Cat. No.

$ Price

Mono Flat Front
Cat. No. b

$ Price

Hinged Front
Cat. No.

$ Price

14-inch-wide Cabinet—Single Phase 3-Wire
18

100 A

30
30

225 A

42

1407.

—

NQ18L1C14

951.

NQB532

118.

NQC32

338.

N/A

—

1647.

—

NQ30L1C14

1191.

NQB532

118.

NQC32

338.

N/A

—

1748.

—

NQ30L2C14

1292.

NQB532

118.

NQC32

338.

N/A

—

2028.

—

NQ42L2C14

1151.

NQB538

118.

NQC38

338.

N/A

—

14-inch-wide Cabinet—Three Phase 4-Wire
18

100 A

30
30

225 A

42

Table 9.12:

1407.

—

NQ418L1C14

951.

NQB532

118.

NQC32

338.

N/A

—

1647.

—

NQ430L1C14

1191.

NQB532

118.

NQC32

338.

N/A

—

1748.

—

NQ430L2C14

1292.

NQB532

118.

NQC32

338.

N/A

—

2028.

—

NQ442L2C14

1151.

NQB538

118.

NQC38

338.

N/A

—

Main Circuit Breaker Interiors—Accepts Plug-On and Bolt-On Branch Breakers

Max.
Number
Main
of
Ratings
Breakers

Total $ Price
Interior, Front,
Box and
Adapter Kit
Type 1

Interior Only (Order Main Circuit Breaker Adapter Kit
Branch Circuit
(Less Circuit Breaker)
Box 14"W x 5.75"
Breakers Seperately)
Db

Type
3R, 5,
12

Cat. No.

$
Cat. No.c Price

Type 1 Enclosure
Mono Flat Front

Hinged Front

$
Price

Cat. No

$
Price

Cat. No

Select QOB
2-pole or
QOB-VH

NQB532

118.

NQC32

338.

N/A

—

NQB532

118.

NQC32

338.

N/A

—

HD, HG, HJ,
HL, OR JD,
JG, JJ, JL,
QB , QD,
QG, QJ

NQB544

118.

NQC44

338.

N/A

—

NQB550

118.

NQC50

359.

N/A

—

Select QOB
3-pole or
QOB-VH

NQB532

118.

NQC32

338.

N/A

—

NQB532

118.

NQC32

338.

N/A

—

HD, HG, HJ,
HL, OR JD,
JG, JJ, JL,
QB , QD,
QG, QJ

NQB544

118.

NQC44

338.

N/A

—

NQB550

118.

NQC50

359.

N/A

—

Cat. No. b

$
$
Price Cat. No. Price

14-inch-wide Cabinet—Single Phase 3-Wire
16 a
100

28 a

Main Breaker Panelboard

30
225

42

1407.

—

NQ18L1C14

951.

—

—

1647.

—

NQ30L1C14

1191.

—

—

1748.

—

NQ30L2C14

1292.

2028.

—

NQ42L2C14

780.

1151.

NQMB2HJ14
or
NQMB2Q14

78.

14-inch-wide Cabinet—Three Phase 4-Wire
15 a
100

27 a
30

225

42
a
b
c

1407.

—

NQ418L1C14

951.

—

—

1647.

—

NQ430L1C14 1191.

—

—

1748.

—

NQ430L2C14 1292.

2028.

—

NQ442L2C14 1151.

780.
NQMB2HJ14
or
NQMB2Q14

78.

Pole spaces shown are available for branch circuits, with spaces deducted for the back-fed main breaker.
Add “F” for flush mount, “S” for surface mount.
All 14” W boxes come with blank endwalls.

Table 9.13:

NQ Accessories
Description

Catalog No.

$ Price

Schedule

Equipment Ground Bars

Main Lug Panelboard

Aluminum

PK27GTA

33.80

PK23GTA+ #1 to #4/0 Al or Cu lug

PK23GTAL

40.70

PK27GTACU

84.00

PE-1A

Copper
Ground Bar Insulator Kit
Filler plate (15 per package)

DE3A

PKGTAB

43.80

DE3A

NQFP15d

68.00

PE1A

HLO1

9.90

Handle Attachments—Branch Circuit Breakers
Handle lock-off
Handle tie - (QO and QOB only)

QO1HT

3.80

Handle padlock attachment—1-pole

QO1PA

10.70

2- and 3-pole

QO1PL

10.70

Handle tie and lock-off for three 1-pole (QO, QOB)

QO3HT

13.40

d

9-8

DE2A

Filler Plates are $3.00 each and must be ordered in packages of 15.

PE1A

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

NQ Merchandised
Panelboards

NQ Merchandised Accessories
Class 1640 / Refer to Catalog 1640CT0801

www.schneider-electric.us

NQ Merchandised Neutrals
200% Neutral Kit

Mains
Ampacity

Catalog No.
NQNL1
NQNL2 or NQNL2ACCYb
NQNL4a

100
225
400
600
a
b

Copper 100% Neutral Kit

$ Price
315.
426.
639.

Box Add

Schedule

no adder

PE-1A

no adder

PE-1A

Catalog No.
NQN1CU
NQN2CU
NQN6CU
NQN6CUa

Not Available

$ Price

Box Add

Schedule

192.

no adder

PE-1A

585.

no adder

PE-1A

PANELBOARDS

Table 9.14:

Not to be used with SFL, FTL, or SFB. These combinations are factory assembled only.
For 225A panel with SFL, FTL, or SFB, use NQNL2ACCY (enclosure size increases by 6 inches). Otherwise, use NQNL2.

NQ Merchandised Sub-feed Lugs, Feed-through Lugs and Sub-feed Breakers
Sub-feed Lugs (N/A in MCB Interiors)

Mains
Ampacity
100 A

Catalog No.
NQSFL1

225 A

NQSFL2

400 A

$ Price
155.
203.

NQSFL4

600 A

260.

Schedule
PE-1A
PE-1A
PE-1A

Sub-feed Circuit Breaker Kits (breaker not incl.)

Feed-through Lugs
Catalog No.
100 A not available;
NQFTL2Lc
NQFTL2Hd
NQFTL4Lc
NQFTL4Hd

$ Price
—

Single SFB
Schedule
—

476.
507.

Catalog No.
—
NQSFB2Q or
NQSFB2HJ

PE-1A
PE-1A

$ Price

Two SFB
Schedule
—

—
1029.

Use the 2 SFB kit

Use FTL

Catalog No.
—

$ Price
—

Schedule
—

PE-1A

—

—

—

—

NQSFB4Q or
NQSFB4HJ

1290.

PE-1A

Factory Assembled Only

9

Table 9.15:

Note: See Table 9.16 and Table 9.17 for box selection table.
c
The final character L indicates the kit is used for Low circuit count interiors 30 and 42.
d
The final character H indicates the kit is used for High circuit count interiors 54, 72, and 84.

e

MH26 —
— Use FTL
MH32 MH38 MH50 Use FTL
— MH44 MH50 Use FTL
— MH50 MH62 Use FTL
— MH56 MH68 Use FTL

Sub-feed Circuit Breakers
400 A 600 A
(two) (two)
—
MH74
MH74
MH86
e

100 A

18
30
42
72
84

—
—
—
—
—

AL Compression Lug Kit

400 A

—

—
MH62
MH68
MH80
MH80

MH50
MH62
MH68

Sub-feed Circuit Breakers
600 A

100 A
—
—
—
—
—

CU Mechanical Lug Kit

100
225

Catalog No.
NQALV1
NQALV2

Lug Wire Range
one #8–1/0 AWG
one #4–300 kcmil

$ Price
117.00
33.00

Catalog No.
NQCUM1
NQCUM2

400

NQALV4

two 2/0–500 kcmil

663.00

NQCUM4

600

NQALV6

two 2/0–500 kcmil

1208.00

NQCUM6

Lug Wire Range
one #6–2/0 AWG
one #6–250 kcmil
one 1/0–750 kcmil
two 1/0–350 kcmil
one 1/0–750 kcmil
two 1/0–350 kcmil

225 A
(one)
—
MH62
MH68
MH74
MH80

400 A
(two)
—
MH86
MH86
f
f

600 A
(two)

CU Compression Kit
$ Price

Catalog No.
NQCUV1
NCQUV2

Lug Wire Range
one #6–1/0 AWG
one 2/0–300 kcmil

636.00

NQCUV4

one 400–700 kcmil

767.00

1139.00

NQCUV6

two 250–500 kcmil

1364.00

347.00

$ Price
345.00
417.00

NQ Accessories
Description

Catalog No.

Sub-feed (Bolt-on)
2-pole
3-pole
Equipment Ground Bars
Aluminum
PK23GTA+ #1 to #4/0 Al or Cu lug
Copper
Ground Bar Insulator Kit
Filler plate (15 per package)
Circuit I.D. Number Strips
1–102 odd/even (left side numbered 1,3,5 ...101)
103–204 odd/even (left side numbered 103,105,107 ... 203)
1–102 sequential (left side numbered 1,2,3 ... 102)
103–204 sequential (left side numbered 103,104,105 ... 204)
6 in. Extension
12 in. Extension
Rail and Deadfront Extensions
18 in. Extension
24 in. Extension
Touch-up paint USAS #49 Gray (Aerosol can)
Handle Attachments—Branch Circuit Breakers
Handle lock-off
Handle tie - (QO and QOB only)
Handle padlock attachment—1-pole
2- and 3-pole
Handle tie and lock-off for three 1-pole (QO, QOB)
Handle tie for two 10–30 A single pole QO(B) circuit breaker
Handle tie for three 10–30 A single pole QO(B) circuit breaker
Handle Padlock Attachment for Padlocking in OFF position
For padlocking 1P QO circuit breaker in OFF position only, fixed attachment
For padlocking 2P and 3P QO circuit breaker in OFF position only, fixed attachment
For padlocking 1P QO-GFI, QO-AFI, QO-CAFI, and QO-EPD circuit breakers in OFF position only, fixed attachment
For padlocking 2P QO-GFI and QO-EPD circuit breakers in OFF position only, fixed attachment
Neutral or Ground Lugs
#10 to #2 Al or #14 to #4 Cu
#4 to #1/0 Al or Cu
#1 to #4/0 Al or Cu
Endwalls for MH Enclosures
Blank (one per package)
With Knockouts (one per package)
g

225 A

NQ Optional Lugs

Ampacity

Table 9.19:

Feed-through Lugs

Feature
Circuits

f
(c) Requires box longer than available box offer.
NOTE: NQ SurgeLogic SurgeLoc Plug-on SPD appears on page 9-44.

(c) Requires box longer than available box offer.

Table 9.18:

Box Selection Table: Merchandised NQ Vertically Mounted Main
Breaker Panelboards w/ Accessories

Factory
Asssembled
Only

18
30
42
72
84

Feed-through Lugs

A
100 A 225 A 400 A 600 A 100 A 225
(one)
—
—
—
—
—
MH38 MH50
— MH50
Use MH38 MH56
— MH56
225A
— MH62
Interior MH50 MH68
MH56 MH68
— MH68

Factory
Asssembled
Only

Sub-feed Lugs
Feature
Circuits 100 A 225 A 400 A 600 A

Table 9.17:

Factory
Asssembled
Only

Box Selection Table: Merchandised NQ Main Lug Panelboards
with Accessories

Factory
Asssembled
Only

Table 9.16:

$ Price

Schedule

QOB2125SL
QOB3125SL

176.00
176.00

PK27GTA
PK23GTAL
PK27GTACU
PKGTAB
NQFP15g

33.80
40.70
84.00
43.80
68.00

NQ102OE
NQ204OE
NQ102S
NQ204S
NQ6RDE
NQ12RDE
NQ18RDE
NQ24RDE
PK49SP

7.90
7.90
7.90
7.90
252.00
283.00
343.00
397.00
39.00

HLO1
QO1HT
QO1PA
QO1PL
QO3HT
QOHT2
QOHT3

9.90
3.80
10.70
10.70
13.40
10.90
12.80

QO1PAF
QO2PAF
QOGFI1PAF
QOGFI2PAF

43.50
25.80
51.00
38.40

DE2E

QO70AN
Q1100AN
Q1150AN

9.90
11.10
32.40

DE3A

8011010501
8011010401

41.10
41.10

PE1A

DE2A

DE3A
PE-1A
DE3A
PE1A

PE1A

DE1

DE2A

DE2

Filler Plates are $4.50 each and must be ordered in packages of 15.

© 2012 Schneider Electric
All Rights Reserved

PE1A

DE2A

DE2E

DE3A

Discount
Schedule

9-9

QOB Bolt-On
Circuit Breakers

With Visi-Trip™ Indicator for NQ Panelboards
l

Class 690, 730, 910, 950
www.schneider-electric.us

QOB-GFI, QOB-EPD, and QOB-EPE Circuit Breakers

Table 9.21:

Two-pole—
Three-pole—Common Trip
Common Trip
$ Catalog No. $
$
$
Catalog No. Price
Catalog
No. Price
Catalog No. Price
Price
QOB-GFI—QOB Qwik-Gard™ Circuit Breaker With Ground Fault Circuit Interrupter—
UL Class A 4–6 mA People Protection. b
120/240 Vac—
208Y/120 Vac—
120 Vac—10 k AIR
10 k AIR
10 k AIR
15 A QOB115GFI 248. QOB215GFI 444. QOB315GFI 791.
20 A QOB120GFI 248. QOB220GFI 444. QOB320GFI 791.
25 A QOB125GFI 248. QOB225GFI 444.
—
—
30 A QOB130GFI 248. QOB230GFI 444. QOB330GFI 791.
40 A
—
— QOB240GFI 444. QOB340GFI 791.
50 A
—
— QOB250GFI 444. QOB350GFI 791.
60 A
—
— QOB260GFI c 444.
—
—
QOB-VHGFI d
120 Vac—22 k AIR
15 A QOB115VHGFI 497.
20 A QOB120VHGFI 497.
25 A QOB125VHGFI 497.
30 A QOB130VHGFI 497.
QOB-EPD—QOB Equipment protection circuit breakers
with UL Listed 30 mA (EPD) or 100 mA (EPE) equipment protection.
120/240 Vac—
120 Vac—10 k AIR
240 Vac—10 k AIR
10 k AIR
15 A QOB115EPD 417. QOB215EPD 671. QOB315EPDm1077. QOB315EPEm1077.
20 A QOB120EPD 417. QOB220EPD 671. QOB320EPDm1077. QOB320EPE 1077.
25 A QOB125EPD 417. QOB225EPD 671.
—
—
—
—
30 A QOB130EPD 417. QOB230EPD 671. QOB330EPDm1077. QOB330EPEm1077.
40 A
—
— QOB240EPD 671. QOB340EPDm1077. QOB340EPEm1077.
50 A
—
— QOB250EPD 671. QOB350EPDm1077. QOB350EPEm1077.
60 A
—
— QOB260EPD 671.
—
—
—
—
QOB-VHEPD
120 Vac—22 k AIR
15 A QOB115VHEPD 772.
20 A QOB120VHEPD 772.
25 A QOB125VHEPD 772.
30 A QOB130VHEPD 772.
QOB-HM—High magnetic trip circuit breakers
15 A QOB115HMe
39.80
20 A QOB120HMe
QOB-K—Key operated QOB circuit breakers f
120 Vac—10 k AIR
10 A
QOB110K
168.
15 A
QOB115K
168.
20 A
QOB120K
168.
25 A
QOB125K
168.
30 A
QOB130K
168.
(Footnotes for Tables 9.20, 9.21, and 9.22)
a
10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors. 35–60 A
circuit breakers are suitable for use with 75 °C conductors.
b
Do not connect to more than 250 feet of load conductor for the total one-way run to
prevent nuisance tripping.
c
Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load
neutral connection.
d
Recommended for applications where high initial inrush may occur and for individual
dimmer applications.
e
UL Listed as SWD (switching duty) rated suitable for switching 120 Vac fluorescent
lighting loads.
f
Available in single pole construction and can be mounted in any single pole space
which will accept a standard QOB. These circuit breakers can be turned ON or OFF or
RESET with a special key (Catalog No. QOK10) included with the circuit breaker.
These circuit breakers are UL Listed and available as shown in the table.
g
UL Listed for use on circuit feeding fluorescent and High Intensity Discharge (HID)
lighting systems such as mercury vapor, metal halide, or high pressure sodium. These
circuit breakers are physically interchangeable with QOB circuit breakers.
h
UL Listed 5,000 AIR on 3Ø corner grounded delta systems.
i
UL Listed as HACR type for use with air conditioning, heating, and refrigeration
equipment having motor group combinations and marked for use with HACR type
circuit breakers.
j
DC Rating is not available on indicated products.
k
QOB2150VH uses 4 pole spaces. QOB3110VH, QOB3125VH, and QOB3150VH
each use 6 pole spaces. 40A maximum circuit breaker mounted opposite. Use with
75 °C wire only.
l
For QO plug-on circuit breaker pricing, see the tables starting on Digest page 1–2.
m
See note in Instruction Bulletin when using in an enclosure with a QO403 or QON
prefix.
Ampere
Rating a

9

Table 9.20:

One-pole

PANELBOARDS

Table 9.23:

QO/QOB Circuit Breaker Wire Sizes

Breaker Type

Ampere Rating n

Two-pole—Common
Trip

One-pole

Two-pole—
Common Trip h

Three-pole—
Common Trip

Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price

QOB Bolt-On
120 Vac—10 k AIR
48 Vdc—5 k AIR
10 A
QOB110
39.80
15 A
QOB115 ie 39.80
20 A
QOB120 ie 39.80
25 A
QOB125 i
39.80
30 A
QOB130 i
39.80
35 A
QOB135 i
39.80
40 A
QOB140 i
39.80
45 A
QOB145 i
39.80
50 A
QOB150 i
39.80
60 A
QOB160 i
39.80
70 A
QOB170 i
78.
80 A
—
—
90 A
—
—
100 A
—
—
110 A
—
—
125 A
—
—
Molded Case Switch 60 A max—
240 Vac
Molded Case Switch 100 A max—
240 Vac

Table 9.22:
Ampere
Rating a

120/240 Vac—10 k AIR
240 Vac—
48 Vdc—5 k AIR j
10 k AIR
QOB210
89.
—
QOB215 i
89. QOB215H
QOB220 i
89. QOB220H
QOB225 i
89. QOB225H
QOB230 i
89. QOB230H
QOB235 i
89.
—
QOB240 i
89. QOB240H
QOB245 i
89.
—
QOB250i
89. QOB250H
QOB260 i
89. QOB260H
QOB270 i
168. QOB270H
QOB280 ij
240. QOB280H
QOB290 ij
240. QOB290H
QOB2100 ij
240. QOB2100H
QOB2110 ij
501.
—
QOB2125 ij
501.
—

—
240.
240.
240.
240.
—
240.
—
240.
240.
308.
366.
366.
366.
—
—

240 Vac—10 k AIR
48 Vdc—5 k AIR j
QOB310
293.
QOB315 i
293.
QOB320 i
293.
QOB325 i
293.
QOB330 i
293.
QOB335 i
293.
QOB340 i
293.
QOB345 i
293.
QOB350 i
293.
QOB360 i
293.
QOB370 ij
369.
QOB380 ij
419.
QOB390 ij
419.
QOB3100 ij
419.
—
—
—
—

QOB200

89.

—

—

QOB300

293.

QOB2000

234.

—

—

QOB3000

507.

High Interrupting QOB and Specialty Circuit Breakers
One-pole
Catalog No.

Two-pole—Common Trip
$ Price

Catalog No.

$ Price

Three-pole—Common Trip
Catalog No.

$ Price

QOB-VH
120 Vac—22 k AIR
QOB115VHie
72.
QOB120VHie
72.
QOB125VHi
72.
QOB130VHi
72.
QOB140VH
86.
QOB150VH
86.
QOB160VH
86.
QOB170VH
137.
—
—
—
—
—
—
—
—
—
—
—
—

120/240 Vac —22 k AIR
QOB215VHi
171.
QOB220VHi
171.
QOB225VHi
171.
QOB230VHi
171.
QOB240VHi
171.
QOB250VHi
171.
QOB260VHi
171.
QOB270VHi
273.
QOB280VHi
384.
QOB290VHi
384.
QOB2100VHi
384.
QOB2110VHi
1110.
QOB2125VHi
1110.
QOB2150VH k
1223.

240 Vac—22 k AIR
QOB315VHi
440.
QOB320VHi
440.
QOB325VHi
440.
QOB330VHi
440.
QOB340VHi
440.
QOB350VHi
440.
QOB360VHi
440.
QOB370VHi
560.
QOB380VHi
629.
QOB390VHi
629.
QOB3100VHi
629.
QOB3110VH k
1809.
QOB3125VH k
1809.
QOB3150VH k
1809.

120 Vac—65 k AIR
15 A
QHB115i e
122.
20 A
QHB120i e
122.
25 A
QHB125i
122.
30 A
QHB130i
122.
QOB-HID—HID circuit breakers g

120 Vac/240 Vac—65 k AIR
QHB215i
342.
QHB220i
342.
QHB225i
342.
QHB230i
342.

240 Vac—65 k AIR
QHB315i
596.
QHB320i
596.
QHB325i
596.
QHB330i
596.

120 Vac—10 k AIR
120/240 Vac—10 k AIR
15 A
QOB115HIDe
49.50
QOB215HID
108.
20 A
QOB120HID e
49.50
QOB220HID
108.
25 A
QOB125HID
49.50
QOB225HID
108.
30 A
QOB130HID
49.50
QOB230HID
108.
40 A
QOB140HID
49.50
QOB240HID
108.
50 A
QOB150HID
49.50
QOB250HID
108.
QOB-SWN—Switch Neutral—Common Trip—NEC 514.11

240 Vac—10 k AIR
QOB315HID
327.
QOB320HID
327.
QOB325HID
327.
QOB330HID
327.
—
—
—
—

1-pole—2-Wire
2 Spaces —120 Vac
QOB210SWN
116.
QOB215SWN
116.
QOB220SWN
116.
QOB225SWN
116.
QOB230SWN
116.
QOB240SWN
116.
QOB250SWN
116.

2-pole—3-Wire
3 Spaces—120/240 Vac
QOB310SWN
170.
QOB315SWN
170.
QOB320SWN
170.
QOB325SWN
170.
QOB330SWN
170.
QOB340SWN
170.
QOB350SWN
170.

15 A
20 A
25 A
30 A
40 A
50 A
60 A
70 A
80 A
90 A
100 A
110 A
125 A
150 A
QHB

10 A
15 A
20 A
25 A
30 A
40 A
50 A

Table 9.24:

—
—
—
—
—
—
—

—
—
—
—
—
—
—

QO™ Arc-Fault Circuit Breakers o p

Wire Size (AWG)

Al
Cu
10–30 A
#14–8
#14–8
QOB
10–30 A
—
two #14–10
1-pole
35–70 A
#8–2
#8–2
10–30 A
#14–8
#14–8
10–30 A
—
two #14–10
QOB
35–70 A
#8–2
#8–2
2-pole
80–125 A
#4–2/0
#4–2/0
150–200 A
#4–300 kcmil
#4–300 kcmil
10–30 A
#14–8
#14–8
QOB
35–70 A
#8–2
#8–2
3-pole
80–125 A
#4–2/0
#4–2/0
QOB-VH
110–150 A
#4–300 kcmil
#4–300 kcmil
15–30 A
#12–8
#14–8
QOB-GFI and
QOB-EPD
40, 50, or 60 A
#12–4
#14–6
n
10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors.
35–60 A circuit breakers are suitable for use with 75 °C conductors.

9-10

Ampere
Rating a

Standard Interrupting QOB 10,000 AIR Circuit Breakers

Circuit Breaker Type

Ampere
Rating q

1P 120 Vac
10 kAIR
1 Space Required

1P 120 Vac
22 kAIR
1 Space Required

Catalog Number
$ Price
Catalog Number
$ Price
Combination
15 A
QOB115CAFI
306. QOB115VHCAFI
612.
Arc-Fault
20 A
QOB120CAFI
306. QOB120VHCAFI
612.
Interupter
Note: See Digest page 7-12 for accessories.
o
UL Listed as HACR type for use with air conditioning, heating, and refrigeration equipment having
motor group combinations and marked for use with HACR type circuit breakers.
p
QO arc-fault circuit breakers provide branch feeder protection (for example, QO115AFI) or
combination protection (for example, QO115CAFI) as required by the NEC and local code
adoption, and comply with UL 1699.
q
10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors. 35–60 A circuit
breakers are suitable for use with 75 °C conductors.

DE2A

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

NQ Factory Assembled
Panelboards

240 Vac, 48 Vdc
Class 1640 / Refer to Catalog 1640CT0801

www.schneider-electric.us

Base Price (With Solid Neutral)
Main Circuit Breaker (Circuit Breaker Interrupt Rating—pages 6-2 through 6-8) a

Main Lugs
Mains
Rating

60 A
100 A
150 Ac
225 Ac
250 Ac
400 Ac
600 Abc

$ Price
2-pole
—
720.
720.
720.
—

3-pole
—
832.
832.
832.
—

772.

928.

—
1422.
2082.

—
1634.
2326.

Circuit
Breaker

HIC

QOB

2-pole
1192.

3-pole
1464.

QOB

1254.

HD
HD
QB
JD
QD
JD
LA
—

2030.
3180.
2450.
3980.
3084.
4390.
5366.
—

Extra HIC
$ Price

Circuit
Breaker
QOB-VH

2-pole
1258.

3-pole
1586.

1562.

QOB-VH

1382.

1712.

2380.
3530.
2800.
4300.
3434.
4640.
6106.
—

HG
HG

2700.
3840.

3050.
4190.

QG
JG

3740.
4510.

4090.
5100.

JG
LH
—

5040.
7708.
—

6020.
8834.
—

Circuit
Breaker

I-Limiter™

$ Price

HJa

2-pole
2950.
2950.
2950.
2950.
4000.

3-pole
3300.
3300.
3300.
3300.
4350.

QJ
JJa

3970.
6450.

JJa
LJ
LJ

7100.
10624.
12930.

HJa
HJa

$ Price

Circuit
Breaker
FI
FI
FI
FI
—

2-pole
4088.
4088.
4088.
4088.
—

3-pole
4858.
4858.
4858.
4858.
—

4320.
7280.

KI

7436.

8680.

8020.
10624.
12930.

KI
LR
LR

8264.
13552.
16002.

9672.
13552.
16002.

Equipment Ground Bar—38.
QL, HJ, HL, JJ, and JL circuit breakers are also available.
Copper bus standard
Prices are for 54-circuit and fewer interiors. See the Product Selector for 72- and 84-circuit interior pricing.

Table 9.26:

Branch Circuit Breakers

9

Note:
a
b
c

Standard IC

Table 9.27:

Specialty Branch Circuit Breakers

Plug-On or Bolt-On
Circuit Breaker
Ampere Rating

Plug-On or Bolt-On

$ Price
1-pole
2-pole
120 Vac 120/240 Vac

2-pole
240 Vac

3-pole
240 Vac

3-pole
208Y/120
Vac

Space Only
All Space Only
28.
58.
58.
86.
—
except below
QOB–VH, Space
—
116.
—
174.
—
Only (125–150 A)
10,000 AIR—Branch Circuit Breakers—QO™, QOB, QO-H, QOB-H
15–60 A
68.
134.
260. d
352.
—
70 A
100.
208.
296. d
396.
—
80–100 A
—
262.
380. d
458.
—
110–125 A
—
482.
—
—
—
10,000 AIR—Combination Arc Fault Circuit Interrupters—QO-CAFI,
QOB-CAFI
15–20 A
470.
—
—
—
—
10,000 AIR—Qwik–Gard™—Class A—QO-GFI, QOB-GFI
Provided with a 5 mA setting on ground fault sensor
15–30 A
272.
488.
—
—
920.
40–50 A
—
488.
—
—
920.
60 A
—
488.
—
—
—
10,000 AIR—Qwik–Gard—Class A—QO-EPD, QOB-EPD
Provided with a 30 mA setting on ground fault sensor
15–30 A
462.
828.
—
1210.
—
40–50 A
—
828.
—
1210.
—
60 A
—
828.
—
—
—
10,000 AIR—Qwik–Gard—Class A—QO-EPE, QOB-EPE
Provided with a 100 mA setting on ground fault sensor
15–30 A
—
—
—
1210.
—
40–50 A
—
—
—
1210.
(High Interrupting Capacity)
22,000 AIR Branch Circuit Breakers—QO-VH, QOB-VH
15–30 A
92.
212.
—
462.
—
35–60 A
—
212.
—
462.
—
70 A
—
292.
—
556.
—
80–100 A
—
378.
—
606.
—
110–125 A
—
1022.
—
—
1746.e
150 A
—
1140. e
—
—
22,000 AIR—Combination Arc Fault Circuit Interrupters—QO-VHCAFI,
QOB-VHCAFI
15–20 A
680.
—
—
—
—
22,000 AIR—Qwik-Gard—Class A—QO-VHGFI, QOB-VHGFI
15–30 A
575.
—
—
—
42,000 AIR Branch Circuit Breakers—QOH
35–60 A
—
368. f
—
—
70 A
—
596. f
—
—
80–100 A
—
688. f
—
—
110–125 A
—
1402. f
—
—
65,000 AIR Branch Circuit Breakers—QH, QHB
15–30 A
144.
348.
—
596.

Circuit Breaker
Ampere Rating

$ Price
1-pole
120 Vac

2-pole
120/240 Vac

2-pole
240 Vac

3-pole
240 Vac

Specialty Branch Circuit Breakers (10,000 AIR)
For High Intensity Discharge Lighting—QO-HID, QOB-HID
15–30 A
78.
148.
—
376.
40–50 A
78.
148.
—
—
Switch Neutral—QO-SWN, QOB-SWN
1-pole
2-pole
—
2-wire
—
3-wire
15–50 A
(2 spaces)
(3 spaces)
—
154.
—
220.
High Magnetic Trip (For applications subject to high initial inrush)—
QO-HM, QOB-HM
15–20 A
68.
—
—
—

Sub-feed Circuit Breakers
Main lugs or main circuit breaker interior—1Ø or 3Ø.
Maximum 1 circuit breaker per 225 A main lug or 250 A main
circuit breaker panelboard, 2 circuit breakers per 400–600 A
panelboard.
Table 9.28:

Sub-feed Circuit Breaker (110–225 A)
(SeeTable 9.29 for correct box size.)

No. of
Poles
2
3
Space
g

Ampacity

QD

QG

1762.
2296.
826.

3812.
4608.
826.

HD
2456.
2872.
826.

HG

JD

3500.
3798.
826.

JG

3020.
3370.
826.

4220.
5100.
826.

QJ, HJ, HL, JJ, and JL circuit breakers are also available.

Sub-feed Circuit Breaker Cabinet Data

Max. No. of
Branch Spaces
(Does not include
sub-feed
circuit breaker
spaces)
30
42
54
72
84
h

QB

110–225 A 1218.
110–225 A 1848.
110–225 A 826.

Table 9.29:

—
—
—
—
—

Box Height (20 in. W x 5.75 in. D)
225 A

250 A

Main
Lug

Main
Circuit
Breaker
62
68
68
74
80

50
56
56
62
68

400 A
Main
Lug
74
74
80
86
—

Main
Circuit
Breaker
86
86
—
—
—

600 A
Main
Lug

Main
Circuit
Breaker

74
80
80
86
—

Not
available
with MCB

Not Available in Type 3R, 5, 12 if subfeed breaker is over 150 A.

—

Note: Shunt Trip, Auxiliary Switch, and Alarm Switch—accessories for circuit
breakers—add $ Price from page 7-12.
d
UL Listed for use on 3Ø, grounded BØ systems, (5,000 AIR for this
application).
e
Bolt-on only; 2-pole requires 4 vertical spaces, 3-pole requires 6 vertical
spaces.
f
Plug-on only.

© 2012 Schneider Electric
All Rights Reserved

PE1

Discount
Schedule

PANELBOARDS

Table 9.25:

9-11

NQ Factory Assembled
Panelboards

Common Features
Class 1640 / Refer to Catalog 1640CT0801
www.schneider-electric.us

9

Sub-feed Lugs

Table 9.39:

NOTE: Available on main lug interiors only, 1Ø or 3Ø.

Table 9.30:

Panelboard
Ampacity

Sub-feed Wire Range Per Phase

PANELBOARDS

Mains
Rating

Incoming

Outgoing

Price
per
Panel

100
225
400

one #6-2/0 Al or Cu
one 1/0-350 kcmil Al or Cu
one 1/0-750 kcmil Cu only

one #6-2/0 Al or Cu
one 1/0-350 kcmil Al or Cu
one 1/0-750 kcmil Cu only

$128.
$128.
$164.

Table 9.31:

Sub-feed Lug Cabinet Data
100 A

225 A

400 A

18
30
42
54
72
84

MH26
MH32
—
—
—
—

—
MH38
MH44
MH44
MH50
MH56

—
MH50
MH50
MH50
MH62
MH68

Table 9.41:

100 A
225 A
400 A
600 A

one #6-2/0 Al or Cu
one #6–350 kcmil Al or Cu
one 1/0–750 kcmil or two 1/0–350 kcmil Al or Cu
two 1/0–750 kcmil Al or Cu

$ Price
344.
344.
826.
826.

a

38
38
50
56

50
50
62
68

50
56
68
68

62
62
74
80

68
80
—
—

$ Price Adder
38.
52.
86.

$ Price
Adder

Standard white face/black letter laminated bakelite,
1 in. x 3.5 in., adhesive backed or screw mountable with
screws in a bag assembly (price includes engraving)

Table 9.45:
78.

128.
388.
Standard

80 kA
100 kA
120 kA
160 kA
200 kA
240 kA

148.
168.
168.

Price Per Pole Adder
H Frame

J Frame LA Frame LC Frame

58.
70.
70.

98.
108.
108.

148.
148.
148.

148.
168.
168.

b

Voltage
120 / 240 V

208 Y / 120 V

6170.
6540.
7370.
8430.
9720.
10840.

240 / 120 HLD

6540.
7370.
7870.
8620.
9770.
12370.

6540.
7370.
7870.
8620.
9770.
12370.

SurgeLogic units occupy 12 circuit positions (6 adjacent mounting
spaces per side.)

132.

200% Rated Neutrals

one #6-2/0 kcmil Al or Cu per lug
one #6-350 kcmil Al or Cu per lug
one #1/0-750 kcmil Al or Cu per lug or
two 1/0-300 kcmil per lug

Surgelogic SPD Options

Description

Panelboards with 200% rated neutrals are not available
Add Per Panel
with 250 A J- and K-frame main circuit breakers or
$ Price
integral lighting contactors

9-12

600A

148.
148.
148.

Surgelogic™ SurgeLoc Plug-On SPD b

Surge Current
Rating kA

Table 9.46:

$ Price
Adder

100–600 A

a

400A

Copper Neutrals

Copper Neutrals

400 Aa

58.
108.
108.

Optional Factory Assembled Lugs
for Main Circuit Breaker Interiors

Aluminum Compression Lugs
Copper Mechanical Lugs
Copper Compression Lugs

$ Price
Adder

Copper Bus Bars

100 Aa
225 Aa

225A

58.
70.
70.

Main Circuit Breaker Interiors:

Copper Bus Bars

100 A, 225 A, 250 A
400 A
600 A

Table 9.38:

Price Per Pole Adder
100A

Note: Optional lugs are not available for Q frame main or QOB
circuit breakers

Name Plates

Name Plates

Table 9.37:

1516.

Optional Factory Assembled Lugs
for Main Lug Interiors

Main Lug Interiors:

Table 9.44:

Equipment Ground Bar
Copper Ground Bar (add to Equipment Ground Bar price)
Insulated/Isolated Ground Bar
(add to Equipment Ground Bar price)

Table 9.36:

$ Price Adder

Ground Bars

Ground Bars

Table 9.35:

Weatherproof or Dusttight Cabinets—Type 3R, 5, 12

Aluminum Compression Lugs
Copper Mechanical Lugs
Copper Compression Lugs

8.75 in. deep box, ship fully assembled only.

Table 9.34:

836.

400 and 600 A NQ panelboards with sub-feed circuit breakers are
not available with a weatherproof enclosure (Use I-Line).

600 A

62
68
80
80

646.

Note: 600 A L-Frame main circuit breaker NQ panelboards are
not available with a weatherproof enclosure (Use I-Line)

Table 9.43:

400 A

Main
Main
Main
Main Lugs Circuit Main Lugs Circuit Main Lugs Circuit
Breaker
Breaker
Breaker a

30
42
72
84

Add Per Panel
$ Price

400 A NQ panelboards are available with a subfeed breaker up to
150 A. See Table 9.29 on page 9-11.

Box Height (20 in. W x 5.75 in. D)
250 A

Hinged Door-in-Door Trims

Weatherproof or Dusttight Cabinets

Feed-through Lug Cabinet Data
225 A

140.

Hinged Door-in-Door Trim has piano hinge down one side.
Inner door has a lock, outer door is retained with screws
Hinged Door-in-Door with Outer Door Lock in place of screws

ó

Max. No.
of Branch
Spaces

$ Price Adder

Hinged Door-in-Door Trim

Table 9.42:

Feed-Through Wire Range Per Phase

Metal Directory Frames

Replaces standard plastic stick-on directory pouch

Feed-through Lugs

Table 9.33:

(2) 1/0 Cu or Al
(2) #4-300kcmil
(2) 4/0 Cu or (2) 300 kcmil Al
(2) #4-300 kcmil
(4) 3/0 Cu or
(4)
250
kcmil
Al
(2) 1/0-300 kcmil or
400 A
(2) 600 kcmil Cu
(1) 750 kcmil
(2) 750 kcmil Al
Note: Neutral conductors must be of size and quantity per table above.

Metal Directory Frame

Feed-through Lugs
Mains
Rating

Actual Lug Wire
Range

Neutral Conductors Required

100/125
225

Table 9.40:

Box Height (20 in. W x 5.75 in. D)

Max. No. of
Branch Spaces

Table 9.32:

NQ Main Neutral Conductors—Required Size
and Quantity

Surge Counter
Dry Contacts
Remote Monitor

$ Price
Standard
Standard
2588.

Note: Additional factory modifications, See Digest page 9-38.

586.
763.
950.

Two incoming neutral lugs per panel

PE1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

NF Merchandised
Panelboards

20-inch Wide Enclosures 480Y/277 Vac Max.
Class 1670 / Refer to Catalog 1670CT0701

www.schneider-electric.us

NEMA 1 Enclosure
$ Total Price a

Mains
Rating

Interior Only b

Box
20 in. W x 5.75 in. D d

NEMA
NEMA 1
Catalog No. c $ Price Catalog No.
3R, 5, 12
(Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire
2056.
3638.
NF418L1
1446.
MH26
18
125
2448.
4030.
NF418L1C
1838.
MH26
2406.
3970.
NF430L1
1766.
MH32
30
125
2802.
4366.
NF430L1C
2162.
MH32
2881.
4435.
NF430L2
2219.
MH38
30
250
3286.
4840.
NF430L2C
2624.
MH38
3194.
5021.
NF442L2
2418.
MH44
42
250
3602.
5429.
NF442L2C
2826.
MH44
4370.
6067.
NF454L2
2616.
MH50
54
250
4775.
6472.
NF454L2C
3021.
MH50
4800.
6485.
NF466L2
3800.
MH62
66g
250
5442.
7127.
NF466L2C
4442.
MH62
3308.
5075.
NF430L4
2466.
MH50
30
400
3716.
5483.
NF430L4C
2874.
MH50
3572.
5325.
NF442L4
2673.
MH56
42
400
3895.
5648.
NF442L4C
2996.
MH56
5285.
6957.
NF466L4
4200.
MH74
66g
400
5792.
7464.
NF466L4C
4707.
MH74
6524.
8261.
NF484L4
5346.
MH86
84g
400
7169.
8906.
NF484L4C
5991.
MH86
30
600
3838.
—
NF430L6C
2996.
MH50
42
600
4087.
—
NF442L6C
3188.
MH56
66g
600
6094.
—
NF466L6C
5009.
MH74
84g
600
7553.
—
NF484L6C
6375.
MH86
800

Table 9.48:

Catalog No.

$ Price

NC26( )
NC26( )
NC32( )
113.
NC32( )
NC38( )
113.
NC38( )
NC44( )
113.
NC44( )
NC50( )
113.
NC50( )
NC62( )
113.
NC62( )
NC50V( )
113.
NC50V( )
NC56V( )
113.
NC56V( )
NC74V( )
113.
NC74V( )
NC86V( )
113.
NC86V( )
113. NC50V( )
113. NC56V( )
113. NC74V( )
113. NC86V( )
Factory Assembled Only
113.

497.
527.
549.
663.
729.
887.
729.
786.
972.
1065.
729.
786.
972.
1065.

Hinged Front
Catalog No.
NC26( )HR
NC26( )HR
NC32( )HR
NC32( )HR
NC38( )HR
NC38( )HR
NC44( )HR
NC44( )HR
NC50( )HR
NC50( )HR
NC62( )HR
NC62( )HR
NC50V( )HR
NC50V( )HR
NC56V( )HR
NC56V( )HR
NC74V( )HR
NC74V( )HR
NC86V( )HR
NC86V( )HR
NC50V( )HR
NC56V( )HR
NC74V( )HR
NC86V( )HR

$ Price

620.
657.
687.
830.
912.
887.
912.
983.
1215.
1430.
912.
983.
1215.
1430.

NEMA 3R, 5, 12 Enclosure f
Enclosure
20 in. W x 6.5 in. D
Height (In.)
Catalog No.
$ Price
MH26WP
2192.
MH26WP
MH32WP
2204.
MH32WP
MH38WP
2216.
MH38WP
MH44WP
2603.
MH44WP
MH50WP
2609.
MH50WP
MH62WP
2685.
MH62WP
MH50WP
2609.
MH50WP
MH56WP
2652.
MH56WP
MH74WP
2757.
MH74WP
MH86WP
2915.
MH86WP
Factory
Assembled
Only
—
—

26
32
38
44
56
62
50
56
74
86
50
56
74
—

NF Main Circuit Breaker Interiors—Use I-Line Panelboards on 480 V 3Ø3W Delta Applications

Max. No. of
$ Total Price a
One-pole Mains
EDB
Circuit Rating
NEMA
NEMA 1
Breakers
3R, 5, 12

NEMA 1 Enclosure
NEMA 3R, 5, 12 Enclosure f
Main Circuit
Main
Interior Only b
Box
Mono-Flat™
Enclosure
Breaker Adapter Kit Circuit
Hinged
Front
20 in. W x 5.75in. D d
Front e
20 in. W x 6.5 in. D Height
Breaker
(In.)
Kit
$ Price Frame Catalog No. c $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price

(Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire
2056.
3638.
15
125
—
2448.
4030. Back-fed
EDB, EGB
Main
or EJB
2406.
3970. Breakerh
27
125
—
2802.
4366.
18

125

30

125

30

250

42

250

54

250

66g

250

30

400

42

400

66g

400

a
b
c
d
e
f
g
h
i

$ Price

Mono-Flat™ Front e

2888.
3280.
3322.
3718.
3841.
4246.
4097.
4505.
5278.
5683.
5665.
6307.
4246.
4654.
4514.
4837.
6158.
6665.

4442.
4834. N150MH
or
5149. N100MFIi
5545.
5608.
6013.
5850.
6258. N250MJ
or
6947. N250MKCi
7352.
7337.
7979.
5931.
N400Mi
6339.
6195.
N400Mi
6518.
7895.
N400Mi
8402.

HD/HG/
780. HJ/HL
or FI
780.
780.
780.

JD/JG/
JJ/JL
or KI

780.
780.
780.
780.

LA/LH

NF418L1
NF418L1C
NF430L1
NF430L1C
NF418L1
NF418L1C
NF430L1
NF430L1C
NF430L2
NF430L2C
NF442L2
NF442L2C
NF454L2
NF454L2C
NF466L2
NF466L2C
NF430L4
NF430L4C
NF442L4
NF442L4C
NF466L4
NF466L4C

1446.
1838.
1766.
2162.
1446.
1838.
1766.
2162.
2219.
2624.
2418.
2826.
2616.
3021.
3800.
4442.
2466.
2874.
2673.
2996.
4200.
4707.

MH26
MH26
MH32
MH32
MH38
MH38
MH44
MH44
MH50
MH50
MH56
MH56
MH62
MH62
MH74
MH74
MH62
MH62
MH68
MH68
MH86
MH86

113.
113.
113.
113.
113.
113.
113.
113.
113.
113.
113.

NC26( )
NC26( )
NC32( )
NC32( )
NC38( )
NC38( )
NC44( )
NC44( )
NC50( )
NC50( )
NC56( )
NC56( )
NC62( )
NC62( )
NC74( )
NC74( )
NC62V( )
NC62V( )
NC68V( )
NC68V( )
NC86V( )
NC86V( )

497.
527.
549.
663.
729.
786.
786.
972.
887.
948.
1065.

NC26( )HR
NC26( )HR
NC32( )HR
NC32( )HR
NC38( )HR
NC38( )HR
NC44( )HR
NC44( )HR
NC50( )HR
NC50( )HR
NC56( )HR
NC56( )HR
NC62( )HR
NC62( )HR
NC74( )HR
NC74( )HR
NC62V( )HR
NC62V( )HR
NC68V( )HR
NC68V( )HR
NC86V( )HR
NC86V( )HR

620.
657.
687.
830.
912.
983.
983.
1215.
1109.
1185.
1430.

MH26WP
MH26WP
MH32WP
MH32WP
MH38WP
MH38WP
MH44WP
MH44WP
MH50WP
MH50WP
MH56WP
MH56WP
MH62WP
MH62WP
MH74WP
MH74WP
MH62WP
MH62WP
MH68WP
MH68WP
MH86WP
MH86WP

2192.

26

2204.

32

2216.

38

2603.

44

2609.

50

2652.

56

2652.

56

2757.

74

2685.

62

2742.

68

2915.

86

Total Price includes: interior, front, main circuit breaker adapter kit, and enclosure.
Order branch circuit breakers separately.
“C” suffix indicates copper bussing.
Embossed mounting holes add a 0.25-inch standoff to back of MH box.
Add “F” for flush mount, “S” for surface mount.
Enclosure includes trim kit.
Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits.
Back-fed EDB 125 A 3 pole main circuit breaker must be ordered separately and field installed. Maximum breaker rating opposite is 20A.
Select the appropriate main circuit breaker from pages starting on 7-21 and add the circuit breaker Price to the total Price of the panelboard.

Table 9.49:

NF Merchandised SPD Box Selection Table
Main Lug Panelboard Box Requirements

Mains
Rating

Max.
Breaker
Spaces

250A
400 A

42
42

NEMA 1
Enclosure
Box
MH56
MH68

© 2012 Schneider Electric
All Rights Reserved

$ Price
113.

Front
$ Price
Hinged
$ Price
NC56( )
887. NC56( )HR
1109.
NC68V( )
972. NC68V( )HR 1215.

Main Circuit Breaker Panelboard Box Requirements

NEMA 3R, 5, 12 Enclosure
Enclosure
MH56WP
MH68WP

PE1A

$ Price
2685.
2757.

Discount
Schedule

NEMA 1 Enclosure
Box
MH68
MH80

$ Price
113.

Front
NC68( )
NC80( )

PANELBOARDS

Max No. of
Single Pole
EDB Circuit
Breakers

NF Main Lug Interiors—Use I-Line™ Panelboards on 480 V 3Ø3W Delta Applications

NEMA 3R, 5, 12
Enclosure

$ Price
Hinged
$ Price Enclosure $ Price
972.
NC68( )HR
1215. MH68WP
2742.
1722. M/B NC80V( )HR 1430. MH80WP
2915.

9-13

9

Table 9.47:

NF Merchandised
Panelboards

Accessories
Class 1670 / Refer to Catalog 1670CT0701
www.schneider-electric.us

9

Table 9.50:

NF Merchandised Neutrals

Mains
Ampacity
125
250
400
600

PANELBOARDS

a

200% Neutral Kit
$ Price
Box Add
1029.
No Adder
1277.
1914.
No Adder
Factory Assembled Only

Catalog No.
NFNL1
NFNL2
NFNL4a

Schedule

Copper 100% Neutral Kit
$ Price
Box Add

Catalog No.
NFN1CU
NFN2CU
NFN6CU
NFN6CUa

PE-1A
PE-1A

Schedule

405.

No Adder

PE-1A

1148.

No Adder

PE-1A

Not to be used with SFL, FTL, or SFB. These combinations are factory assembled only.

Table 9.51:

Modifications (Single- or Three-phase)
Sub-feed Lugs b c

Mains
Ampacity
125
250
400
600
800
Note:
b
c
d
e
f

Catalog No.

$ Price Schedule Catalog No.

NF125SFL
NF250SFL
NF400SFL e

167.
213.
356.
—
—

f

Sub-feed Circuit Breaker Kits b
(circuit breaker not Included) d
Single Sub-feed
Twin Sub-feed
Circuit Breaker
Circuit Breakers
Catalog No.
$ Price Schedule Catalog No.
$ Price
NF250SFBH/NF250SFBJ
1029. PE-1A
—
—
—
—
—
NF600SFBH
1290.
—
—
—
NF600SFBJ

Feed-through Lugs b c

PE-1A
PE-1A
PE-1A
—
—

$ Price Schedule

NF125FTL
NF250FTL
NF400FTL

336.
476.
507.
—
—

f

Mains
Ampacity

PE-1A
PE-1A
PE-1A
—
—

250
400
600

FACTORY ASSEMBLED ONLY

800

FACTORY ASSEMBLED ONLY

Schedule

—
PE1A

NF250SFBH and NF600SFBH are for use with HDL, HGL, HJL, and HLL circuit breakers. NF600SFBJ are for use with JDL, JGL, JJL, and JLL circuit breakers.
Available factory assembled only on non-linear panelboards.
Select box from the Box Selection Table.
Order appropriate circuit breaker.
Use copper wire only.
Available factory assembled only.

Table 9.52:

Special Features Box Selection Table—Standard Mechanical Lugs Only
Main Lugs Only

Feature

Sub-feed Lugs

Feed-through Lugs

Sub-feed Circuit Breaker

No. of Circuits

18

30

42

66

84

18

30

42

66

84

30

42

66

Ampacity
100/125
250
400
600
800

Cat. No.
MH26
—
—

Cat. No.
MH32
MH38
MH50

Cat. No.
—
MH44
MH56

Cat No.
—
MH62
MH74

Cat No.
—
—
MH86

Cat. No.
MH32
—
—

Cat. No.
MH38
MH50
MH56

Cat. No.
—
MH56
MH62

Cat. No.
—
MH74
MH80

Cat. No.
—
—
MH92

Cat. No.
—
MH56
MH68

Cat. No.
—
MH62
MH74

Cat. No.
—
MH80
—

—

g

g

g

g

—

g

g

g

g

g

g

g

g

Available factory assembled only.

Table 9.53:

Special Features Box Selection Table—Standard Mechanical Lugs Only (continued)

Feature
No. of Circuits
Ampacity
100/125
250
400h
600
h

Ampacity

CU Mechanical Lug Kit
CU Compression Lug Kit i
Lug Wire Range
$ Price Schedule Catalog No.
Lug Wire Range $ Price Schedule
#6–2/0 AWG
NFCUV1 k
one #6–1/0
345.
347. PE-1A
PE-1A
#6–250 kcmil
NFCUV2 k
one 2/0–300 kcmil
417.
one
1/0–750
kcmil,
PE-1A
NFCUM4
987. PE-1A
NFCUV4
one 400–750 kcmil
767. PE-1A
two 1/0–350 kcmil
PE-1A
NFCUM6
two 1/0–750 kcmil
2236. PE-1A
NFCUV6
two 250–500 kcmil
1364. PE-1A
Contact your local Schneider Electric representative or distributor

AL Compression Lug Kit
Lug Wire Range $ Price Schedule
one #4–300 kcmil
177.
PE-1A
one 250–350 kcmil
333.

125
250
400

NFALV4

two 2/0–500 kcmil

1122.

600
800

NFALV6

two 2/0–500 kcmil

1206.

Catalog No.
NFCUM1
NFCUM2

Use copper wire only.
Use of this kit requires an additional 6 in. added to box height.
Use of this kit to terminate larger than standard wire size requires an additional 6 in. added to box height.

NF Accessories

Description
Aluminum Equipment Ground Bar
Copper Equipment Ground Bar
Large Aluminum Lug for Equipment Ground Bar
Equipment Ground Bar Insulator Kit
Circuit I.D. number strips
1–102 odd/even (left side numbered 1, 3, 5...101)
103–204 odd/even (left side numbered 103, 105, 107...203)
1–102 sequential (left side numbered 1, 2, 3 ...102)
103–204 sequential (left side numbered 103, 104, 105... 204)
Rail and Deadfront Extensions
6 in. Extension
12 in. Extension
18 in. Extension

9-14

Back-fed Main Circuit Breaker
Feed-through Lugs
18
30
Cat. No.
Cat. No.
MH32
MH38
MH38
MH44
—
—
—
—

Optional Main Lug Kits for Main Lug Panelboards
Catalog No.
NFALV1 j
NFALV2

Table 9.55:

l

Sub-feed Circuit Breaker
30
42
Cat. No.
Cat. No.
—
—
MH68
MH74
MH80
MH86

400 A dimension for LA/LH main circuit breakers only.

Table 9.54:

i
j
k

18
Cat. No.
MH44
—
—

Vertical Main Circuit Breaker h
Feed-through Lugs
30
42
66
Cat. No.
Cat. No.
Cat. No.
MH50
—
—
MH62
MH68
MH86
MH68
MH74
MH92
Available factory assembled only.

Catalog No.
PK27GTA
PK27GTACU
PK23GTAL
PKGTAB

$ Price Schedule
33.80 DE-3A
84.00 PE-1A
40.70
DE-3A
43.80

NF102OE
NF204OE
NF102S
NF204S

7.90

NF6RDE
NF12RDE
NF18RDE

252.00
284.00
344.00

PE-1A

Description
Filler plate (15 per package)
EXB Fixed padlock attachment, Lock ON/OFF
for ED, EG, and EJ Circuit Breakers 1, 2, or 3 poles
EXB Fixed padlock attachment, Lock OFF only
for ED, EG, and EJ Circuit Breakers 1, 2, or 3 poles
Oversized Lugs for Neutral or Ground Bar
#10 to #2 Al or #14 to #4 Cu
#4 to #1/0 Al or Cu
#1 to #4/0 Al or Cu
Drip Hood for 20 in. wide enclosures

Catalog No. $ Price Schedule
NFFP15
113.00l PE-1A
EDPA

26.00

DE-2

EDPAF

30.00

DE-2

QO70AN
Q1100AN
Q1150AN
MHT2DH20

9.90
11.10
32.40
315.00

DE-3A
PE-1A

PE-1A

Filler plates are $7.50 each and must be ordered in packages of 15.

PE1A

DE3A

DE1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Circuit Breakers

For NF Merchandised Panelboards
Class 515

www.schneider-electric.us

Table 9.56:

E-frame—125 A, Thermal-magnetic (480Y/277 Vac)

ED, EG, EJ
“D” Interrupting Level
“G” Interrupting Level
“J” Interrupting Level
Terminal
(480Y/277 Vac)
18 kA @ 480Y/277 Vac
35 kA @ 480Y/277 Vac
65 kA @ 480Y/277 Vac
Wire Range
Hold
Trip
Catalog Number
$ Price
Catalog Number
$ Price
Catalog Number
$ Price
1-pole, 277 Vac
15 A
EDB14015ab
EGB14015ab
EJB14015ab
AL30FD
20 A
EDB14020ab
EGB14020ab
EJB14020ab
270
875
150.
255.
408.
#14–#6
25 A
EDB14025b
EGB14025b
EJB14025b
Al or Cu
30 A
EDB14030b
EGB14030b
EJB14030b
35 A
EDB14035b
EGB14035b
EJB14035b
40 A
EDB14040b
EGB14040b
EJB14040b
AL100FD
45 A
EDB14045b
150.
EGB14045b
225.
EJB14045b
408.
630
1800
#14–2/0
50 A
EDB14050b
EGB14050b
EJB14050b
Al or Cu
60 A
EDB14060
EGB14060
EJB14060
70 A
EDB14070
302.
EGB14070
507.
EJB14070
812.
2-pole, 480Y/277 Vac c
15 A
EDB24015b
EGB24015b
EJB24015b
AL30FD
20 A
EDB24020b
EGB24020b
EJB24020b
270
875
536.
776.
1241.
#14–#6
25 A
EDB24025b
EGB24025b
EJB24025b
Al or Cu
30 A
EDB24030b
EGB24030b
EJB24030b
35 A
EDB24035b
EGB24035b
EJB24035b
40 A
EDB24040b
EGB24040b
EJB24040b
AL100FD
536.
776.
1241.
45 A
EDB24045b
EGB24045b
EJB24045b
630
1800
#14–2/0
50 A
EDB24050b
EGB24050b
EJB24050b
Al or Cu
60 A
EDB24060
EGB24060
EJB24060
70 A
EDB24070
756.
EGB24070
1280.
EJB24070
2048.
80 A
EDB24080
EGB24080
EJB24080
756.
1280.
2135.
90 A
EDB24090
EGB24090
EJB24090
AL100FD
100 A
1000
2300
EDB24100
EGB24100
EJB24100
#14–2/0
Al or Cu
110 A
EDB24110
EGB24110
EJB24110
1946.
2586.
3879.
125 A
EDB24125
EGB24125
EJB24125
3-pole, 480Y/277 Vac
15 A
EDB34015b
EGB34015b
EJB34015b
AL30FD
20 A
EDB34020b
EGB34020b
EJB34020b
270
875
669.
1131.
1358.
#14–#6
25 A
EDB34025b
EGB34025b
EJB34025b
Al or Cu
30 A
EDB34030b
EGB34030b
EJB34030b
35 A
EDB34035b
EGB34035b
EJB34035b
40 A
EDB34040b
EGB34040b
EJB34040b
AL100FD
45 A
EDB34045b
669.
EGB34045b
1131.
EJB34045b
1358.
630
1800
#14–2/0
50 A
EDB34050b
EGB34050b
EJB34050b
Al or Cu
60 A
EDB34060
EGB34060
EJB34060
70 A
EDB34070
911.
EGB34070
1292.
EJB34070
2562.
80 A
EDB34080
EGB34080
EJB34080
911.
1292.
2562.
90 A
EDB34090
EGB34090
EJB34090
AL100FD
100 A
1000
2300
EDB34100
EGB34100
EJB34100
#14–2/0
Al or Cu
110 A
EDB34110
EGB34110
EJB34110
2421.
3216.
4826.
EGB34125
EJB34125
125 A
EDB34125
EPDs (Equipment Protection Devices), 1-pole, 277 Vac, Thermal-magnetic with 30 mA ground-fault protectiond
15 A
EDB14015EPDab
EGB14015EPDab
EJB14015EPDab
20 A
270
875
EDB14020EPDab
1151. EGB14020EPDab
1256.
EJB14020EPDab
1409.
#14–#6 Cu
30 A
EDB14030EPDb
EGB14030EPDb
EJB14030EPDb
or
#12–#4 Al
40 A
EDB14040EPDb
EGB14040EPDb
EJB14040EPDb
630
1800
1151.
1256.
1409.
50 A
EDB14050EPDb
EGB14050EPDb
EJB14050EPDb
Note: All EDB, EGB, and EJB circuit breakers are UL Listed as HACR Type. For 50 oC calibration, use a CA suffix. NF branch circuit breakers are fungus proof as standard.
a
UL Listed as SWD (Switching duty rated).
b
UL Listed as HID (High Intensity Discharge rated).
c
UL Listed for use on 240 V Corner-grounded Delta Systems (Grounded B Phase). See data bulletin 2700DB0202.
d
All EPDs occupy two spaces, with or without Alarm Switch option. For alarm switch, add 158 list Price and the suffix BA.

EDB, EGB, EJB
3-pole
15–125 A

Table 9.57:

EDB, EGB, EJB
1-pole
15–70 A

Factory installed Electrical Accessories
Alarm Switch (NO)

Monitors circuit breaker contact status and provides
a remote signal indicating the circuit breaker
contacts are OPEN or CLOSED.
Application
Max Load = 10 A @ 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire

Used with control circuits and is actuated
only when the circuit breaker has tripped.

Table 9.58:

Accessory Package
Auxiliary Switch/Alarm Switch Packageef
Shunt Trip Packageef
Auxiliary Switch/Alarm
Switch/Shunt Trip Packageef
Alarm Switch (N.O.) Package for EPDs only
e
f

Application
Max Load = 7 A @ 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire.

Factory Installed Electrical Accessory Packages for
ED, EG, EJ Circuit Breakers
Suffix
AABA
SA

$ Price
312.
755.

AABASA

1067.

BA

237.

Accessory package takes an additional pole space.
Not available for EPD.

Table 9.59:

Terminal Nut Insert Kit

Circuit Breaker Type
ED, EG, EJ

Qty. per Kit
3

Catalog No.
TIKFD

$ Price
17.40

Minimum Recommended
Supply Transformer (VA)
288
50
Shunt Trip—Trips the circuit breaker from a remote location by means
of a coil energized from a separate circuit. A 120 V shunt trip will
operate at 55% or more of rated voltage.
Application
For use with momentary or maintained push button. 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire.
Coil Burden Max. (VA)

Auxiliary Switch (1A/1B)

Table 9.60:

Table 9.61:
120 V
240 V
480Y/277 V

Table 9.62:

Circuit Breaker Application
Ampere Rating
Optional

Ampere Rating

15–30 A

—

—

35–125 A

EDB, EGB, EJB

15–30 A g

—

EDB, EGB, EJB

15–125 A

EDB, EGB, EJB
—
g

$ Price
39.00
45.00
25.50
16.80
17.85

Interrupt Ratings (kA)
EDB
25
18 (1P), 25
18

EGB
65
35 (1P), 65
35

EJB
100
65 (1P), 100
65

Mechanical Lug Kit Information (Al lugs for use with Al or Cu wire)

Standard

EDB, EGB, EJB
2-pole
15–125 A

Handle Accessories

Circuit Breaker Type
No. of Poles
Catalog No.
EXB Fixed Padlock Attachment, Lock ON/OFF
ED, EG, EJ
1, 2, or 3
EDPA
EXB Fixed padlock attachment, Lock OFF only
ED, EG, EJ
1, 2, or 3
EDPAF
EXB Removable padlock attachment, Lock OFF only
ED, EG, EJ
1, 2, or 3
HPAFD
EXB Handle Ties
Ties 2 – 1P
ECB2HT
ED, EG, EJ
Ties 3 – 1P
ECB3HT

Number of Wires Per Lug
and Wire Range
one #12—#6 AWG Al or
one #14—#6 AWG Cu
one #12—2/0 AWG Al or
one #14—2/0 AWG Cu
one #14—1/0 AWG Cu

Catalog Number

Lugs
Per Kit

AL30FD

3

AL100FD

3

CU100FD

3

$ price
Per Kit

41.30

Factory installed only. Use suffix “LH”

E-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
© 2012 Schneider Electric
All Rights Reserved

DE2

Discount
Schedule

9-15

9

EDB-EPD
1-pole
with Alarm Switch

PANELBOARDS

Ampere
Rating

NF Factory Assembled
Panelboards a

Maximum 480Y/277 Vac
Class 1670 / Refer to Catalog 1670CT0701
www.schneider-electric.us

9

Factory Assembled Pricing
a

Use I-Line™ Panelboards on 480 V 3Ø3W Delta applications.

Table 9.63:

Base $ Price (including solid neutral)

PANELBOARDS

2-pole
100 A
100 A
125 A
150 A
225 A d
250 A d
400 A d
600 A de
800 A e
a
b
c
d
e

Main Circuit Breaker (Circuit Breaker Interrupt Rating—7-2 through 7-8) a b

Main Lugs

Mains
Rating

—
—
846.
—
—
1002
1326.
2366.
3550.

Standard IC

3-pole
—
—
972.
—
—
1152.
1524.
2622.
3900.

Circuit
Breaker
ED c
—
ED c
HD
JD
JD
LA
—
—

2-pole

HIC
3-pole

1636.
—
3372.
3270.
4120.
4500.
5330.
—
—

1882.
—
3762.
3620.
4380.
5140.
6126.
—
—

Circuit
Breaker
EG c
—
EG c
HG
JG
JG
LH
—
—

Extra HIC

2-pole

3-pole

2100.
—
4324.
4048.
5070.
6180.
7712.
—
—

2416.
—
4976.
4398.
5400.
6180.
8864.
—
—

Circuit
Breaker
—
HJ
—
HJ
JJ
JJ
LC
LC
—

2-pole

I-Limiter™
3-pole

—
3248.
—
4070.
6620.
7190.
8506.
9554.
—

—
3598.
—
4420.
7330.
8450.
9776.
10884.
—

Circuit
Breaker
—
FI
—
—
KI
KI
LI
LI
—

2-pole

3-pole

—
4250.
—
—
7266.
9154.
9350.
13640.
—

—
4884.
—
—
8352.
10522.
10746.
15678.
—

HL and JL frame circuit breakers are also available as main circuit breakers.
Contact your local Schneider Electric representative or distributor for Micrologic™ trip main circuit breaker pricing.
Back-fed main circuit breaker.
Prices are for 54-circuit and fewer interiors. See the Product Selector for 66- and 84-circuit interior pricing.
Copper bus only.

Table 9.64:

Branch Circuit Breakers—$ Price per circuit breaker
Standard Interrupting
25,000 AIR @ 240 Vac,
18,000 AIR @ 480Y/277 Vac
ED Bolt-on Branch

Circuit Breaker
Ampere Rating

High Interrupting
65,000 AIR @ 240 Vac,
35,000 AIR @ 480Y/277 Vac
EG Bolt-on Branch

Extra High Interrupting
100,000 AIR @ 240 Vac,
65,000 AIR @ 480Y/277 Vac
EJ Bolt-on Branch

1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price
324.
15–60 A
192.
442.
748.
746.
1264.
518.
1196.
2024.
70 A
342.
872.
1046.
578.
1474.
1710.
924.
2120.
2540.
80–100 A
—
872.
1046.
—
1474.
1710.
—
2120.
2540.
110–125 A
—
2210.
2724.
—
4114.
4754.
—
5300.
6300.
Space Only
42.
84.
126.
42.
84.
126.
42.
84.
126.
Note: All ED, EG, and EJ branch circuit breakers are UL Listed as HACR type.

Table 9.65:

EDB-EPD Equipment Protection Device Branch Circuit Breakers f g
Standard Interrupting
25,000 AIR @ 240 Vac,
18,000 AIR @ 480Y/277 Vac
ED Bolt-on Branch

Circuit Breaker
Ampere Rating

Extra High Interrupting
100,000 AIR @ 240 Vac,
65,000 AIR @ 480Y/277 Vac
EJ Bolt-on Branch

1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price
1472.
—
—
1596.
—
—
1788.
—
—

15–60 A
f
g

High Interrupting
65,000 AIR @ 240 Vac,
35,000 AIR @ 480Y/277 Vac
EG Bolt-on Branch

All 1-pole EDB-EPD branches use 2 poles of mounting space.
For bell alarm in EDB-EPD branch breaker, add 158. to branch breaker price.

Sub-feed Circuit Breaker
Available on 1Ø or 3Ø, 250–800 A main lugs or 250–600 A main circuit breaker interiors
• One sub-feed HD, HG, HJ, or HL or JD, JG, JJ, or JL circuit breaker per 250 A panelboard
• Two sub-feed HD, HG, HJ, or HL or two JD, JG, JJ, or JL circuit breakers per 400 A panelboard (do not mix H and J in a Panel)
• One sub-feed LA, LH, or LC circuit breaker (400 A max.) and one JD, JG, JJ, or JL circuit breaker or two sub-feed JD, JG,
JJ, or JL circuit breakers per 600 A or 800 A panelboard (JJ and LC sub-feed circuit breakers cannot be used together).
Table 9.66:

Sub-feed Circuit Breaker (150–400 A)

No. of
Poles
2
3
h

HD

HG
2456.
2872.

LA
4220.
5100.

LC h

LH
3980.
4916.

5534.
6510.

Space

8634.
10156.

826.
826.

Sub-feed Circuit Breaker Cabinet Data

Max. No. of Branch Spaces
(Does not include sub-feed
circuit breaker spaces)
30
42
54
66
84

9-16

JG
3020.
3370.

JJ and LC sub-feed circuit breakers cannot be used together.

Table 9.67:

i
j
k

JD
3500.
3798.

Box Height (20 in. W x 5.75 in. D)
250 A
Main Lugs
56
62
68
80

400 A LA/LH

Main Breaker
68
74
80

Main Lugs
68
74
80

600 A

Main Breaker
80
86
92

Main Lugs
74
80
86
N/A

800 A

Main Breaker i
80k
86k
92k

Main Lugs j
68
74
80

N/A

600 A main circuit breaker panelboards require an 8.75 in. deep, 26 in. wide box.
800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box.
Dimensions also for 400 A LC/LI main circuit breaker panels.

PE1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

NF Factory Assembled
Panelboards

Common Features
Class 1670 / Refer to Catalog 1670CT0701

www.schneider-electric.us

Sub-feed (Double) Lugs (Standard Aluminum Mechanical Lugs)

Table 9.76:

An additional mains end termination point that can be used to feed out to
another panelboard or device from the incoming service lines.
NOTE: Available on main lug interiors only.
Sub-feed Wire Range
Wire Bending Space per NEC Table 373-6
two #6–2/0 Al or Cu
two 1/0–350 kcmil Al or Cu
two 1/0–600 kcmil Cu
(4) 4/0–500 kcmil Al or Cu
(6) 3/0–500 kcmil Al or Cu

Mains Rating
125 A
250 A
400 A
600 A
800 A

250 A
—
38
44
50

400 A
—
50
56
62

Neutral Conductors Required c

Actual Lug Wire Range

125
250

(2) 1/0 Cu or (2) 1/0 Al
(2) 4/0 Cu or (2) 300 kcmil Al
(4) 250 kcmil Al or
(4) 3/0 Cuor (2) 600 kcmil Al
(4) 500 kcmil Al or (4) 350 kcmil Cu

(2) #6-2/0
(2) #6-350 kcmil
(2) 1/0-300 kcmil or
(1) 1/0-750 kcmil
(2) 1/0-750 kcmil

400 A

800 A a
—
74
80
86

600 A
—
74
80
86

600

Note: Neutral conductors must be of size and quantity per table above.

800 A main lug panelboards require an 8.75 in. deep and 26 in. wide box.

Table 9.78:

Feed-through Lugs (Standard Aluminum Mechanical Lugs)

A second set of lugs assembled at the opposite end from the mains of the
panelboard. Often used to connect another panelboard or device to the
incoming lines. Available on main lugs and main circuit breaker panelboards.
Mains Rating

Feed-through Wire Range Wire Bending Space per NEC
Table 373-6

125 A
250 A

one #6–2/0 kcmil Al or Cu
one #6–350 kcmil Al or Cu
one 1/0–750 kcmil or
two 1/0–350 kcmil Al or Cu
two 1/0–600 kcmil Al or Cu

400 A
600 A

Table 9.79:
344.
344.
826.

Max. No. of
Branch Spaces
18
30
42
54
b
c

100/125 A

250 A

400 A LA/LH

Equipment Ground Bar
Copper Ground Bar (Add to Equipment Ground Bar Price)
Insulated/Isolated Ground Bar (Add to Equipment Ground Bar Price)

Table 9.73:

600 A

Hinged Door-in-Door Trim has piano hinge down one side.
Inner door has a lock, outer door is retained with screws
Hinged Door-in-Door with Outer Door Lock in place of screws

Table 9.74:

Main
Lugs
c

—
74
80
86

—
56
62
68

Table 9.81:

Copper Bus Bars

Table 9.82:

100–600 A
800 A

1516.

$ Price Per Pole Adder
100 A
58.
70.
70.

Main Circuit Breaker Interiors
$ Price Adder
38.
52.
86.

Aluminum Compression Lugs
Copper Mechanical Lugs
Copper Compression Lugs

Table 9.83:

78.

$ Price Adder
458.
624.
Standard

100
120
160
200
240
d

400 A
90.
148.
148.

800 A
200.
196.
316.

$ Price Per Pole Adder
H Frame
59.
70.
70.

J Frame
98.
108.
108.

LA Frame
128.
148.
148.

LC Frame
262.
168.
168.

Voltage
208Y/120 V
3Ø4W
11970.
12548.
13807.
17992.
20583.

240/120 V
3Ø4W High Leg
11970.
15654.
13807.
17992.
20583.

480Y/277 V
3Ø4W
12890.
13340.
14623.
20508.
23598.

Panelboard box height with SPD unit—Contact your local Schneider Electric
representative or distributor.

Surgelogic SPD Options
Surgelogic SPD Options

$ Price Adder
132.
176.

600 A
118.
168.
168.

Surgelogic™ Hard Bus SPD—Model IMA d

Surge Current
Rating kA

$ Price Adder

225 A
58.
108.
108.

Optional Factory Assembled Lugs for Main Circuit Breaker
Interiors

Copper Neutral
Copper Neutral

$ Price Adder

Optional Factory Assembled Lugs for Main Lug Interiors

Aluminum Compression Lugs
Copper Mechanical Lugs
Copper Compression Lugs

Table 9.84:
Table 9.75:

836.

Weatherproof or Dusttight Cabinets (Type 3R, 5, 12)

Main Lug Interiors

Copper Bus Bars

100 A, 250 A
400 A
600 A, 800 A

646.

800 A

Main
Breaker
b

Name Plates

Name Plates
Standard white face/black letter laminated bakelite, 1 in. x 3.5 in.,
adhesive-backed or screw mountable with screws in a bag assembly
(Price includes engraving)

Add Per Panel
$ Price

Hinged Door-in-Door Trim

Ground Bars
Ground Bars

Hinged Door-in-Door Trim

Weatherproof or Dusttight Cabinets —Type 3R, 5, 12
(Not available with panelboards having
LC/LE/LI/LX/LXI main circuit breakers)

600 A main circuit breaker panelboards require an 8.75 in. deep, 26 in. wide box.
800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box.

Table 9.72:

140.

826.

Feed-through Lug Cabinet Data (Standard Aluminum
Mechanical Lugs)

Main
Breaker Main Main Main Main Main Main
Main
(back-fed Lugs Breaker Lugs Breaker Lugs Breaker Lugs
only)
38
32
44
—
—
—
—
—
44
38
50
50
62
56
68
62
50
—
—
56
68
62
74
68
—
—
—
62
74
68
80
74

$ Price Adder

$ Price

Box Height in Inches (20 in. W x 5.75 in. D)
125 A

Metal Directory Frame

Metal Directory Frame
Not available with LC/LI main circuit breaker
(Replaces standard plastic stick-on directory pouch)

Table 9.80:
Table 9.71:

NF Main Neutral Conductors—Required Size and Quantity

Panelboard
Ampacity
Main Lugs Box Height in Inches (20 in. W x 5.75 in. D)
125 A
26
32
—
—

18
30
42
54

Table 9.70:

Table 9.77:

Sub-feed Lug Cabinet Data (Standard Aluminum Mechanical Lugs)

Max. No. of
Branch Spaces

a

128.
128.
344.
344.
522.

Add Per Panel
$ Price
769.
950.
1262.
1894.

9

Table 9.69:

$ Price

200% Rated Neutrals

Panelboards with 200% rated neutrals are available with sub-feed lugs,
feed-through lugs, and main circuit breakers
250 A
400 A
600 A
800 A

Surge Counter
Dry Contacts
Remote Monitor

$ Price
Standard
Standard
2588.

NOTE: For additional factory modifications, See Digest page 9-38.

© 2012 Schneider Electric
All Rights Reserved

PE1

PANELBOARDS

Table 9.68:

Discount
Schedule

9-17

NQ/NF Merchandised Single Row (Column Width) Panelboards
Class 1640 / Refer to Catalog 1670CT0701, 1640CT0801
www.schneider-electric.us

9
PANELBOARDS

NQ Single-Row (Column-width)—240 Vac Bolt-on

NF Single-Row (Column-width)—480Y/277 Vac Bolt-on

(60 A Max. Branch Circuit Breaker)
NQ Application Data

(60 A Max. Branch Circuit Breaker)
NF Application Data

Application: For use on ac only. Meet Federal Specification W-P-115c,
Type 1, Class 1. UL Listed.
Service: 1Ø3W, 3Ø3W, 3Ø4W,
3 Grd. “B” Ø—240 Vac max.
AIR: See the tables starting on Digest page 7-2.
Mains: Type NQ—Bolt-on main lugs: 100 A, 225 A
• Main circuit breaker: 100 A—QOU, 225 A—QB
• See the tables starting on Digest page 7-2 for main circuit breaker
interrupt ratings. See catalog for terminal lug data.
• Main circuit breakers with higher interrupt ratings are available as factory
assembled panelboards.
Branches: Bolt-on QOB, 60 A maximum. QOB 10-60 A 1-, 2- and 3-pole.
See Digest page 9-10 for branch circuit breaker terminal data. QOB-VH and
QHB branch circuit breakers are also available as factory assembled.
Cabinet: Front—Screw cover. Box—galvanized steel with removable endwalls.
Gutters:
• 100 A—4 in. min. mains end, 3 in. min. opposite mains
• 225 A—10 in. min. mains end, 5 in. min. opposite mains

Application: For use on ac only. Meet Federal Specification W-P-115c, Type
1, Class 1. UL Listed.
Service: 480Y/277 Vac, 3Ø4W
AIR: See the tables starting on Digest page 7-2
Mains: Type NF–Bolt-on main lugs: 125 A, 225 A
• Main circuit breaker: 100 A—FA, 100 A—HD, 225 A—JD. See the tables
starting on Digest page 7-2 for main circuit breaker interrupt rating. See
the catalog section for terminal lug data.
• Main circuit breakers with higher interrupt ratings are available as factory
assembled panelboards.

Table 9.85:

Table 9.87:

Max.
No. of
Poles

NQ Single-Row (Column-width)—240 Vac Bolt-on a

Mains
Rating

Total
Box and Interior with Solid Neutral
Front
$ Price
(8.625 in. W. x 5 in. D.)
(Box
(Order branch circuit breakers separately) (Surface Mount)
Interior
Box Height Catalog $ Price
and
Catalog Number $ Price
(In.)
Number
Front)

1 Phase 3-Wire Main Lugs Only
30
225
1669.
NQ830L2C
Main Circuit Breaker—2-pole
20
100
1818.
NQ820B1C
3 Phase 4-Wire Main Lugs Only
30
100
1608. NQ8430L1C
42
225
1938. NQ8442L2C
Main Circuit Breaker—3-pole
30
100
2363. NQ8430B1C
42
225
4961. NQ8442B2C
a

NF Single-Row (Column-width)—480Y/277 Vac Bolt-on

Max. No. Mains
of Poles Rating

1298.

45

LX45TS

371.

1452.

40

LX40TS

366.

1242.
1458.

40
58

LX40TS
LX58TS

366.
480.

1992.
4416.

45
62

LX45TS
LX62TS

371.
545.

Total $ Price
(Box Interior
and Front)

Box and Interior with S/N
(8.625 in. W. x 5.625 in. D.)
Catalog
Number

Main Lugs Only—3 Phase 4-Wire
30
125
2410.
NF8430L1C
42
225
3281.
NF8442L2C
Main Circuit Breaker—3-pole
NF8430M1C
30
100
3767.
NF8430M1HDC
42
225
6660. NF8442M2JDC

Front
(Surface Mount)

Box
Height
(In.)

Catalog
Number

$ Price

2009.
2759.

59
71

NC59TS
NC71TS

401.
522.

3246.

65

NC65TS

521.

6042.

85

NC85TS

618.

$ Price

60 A Maximum Branch—Copper Bus Standard.

Table 9.86:

Table 9.88:

Cable Troughs and Pull Boxes

Cable Troughs (L=Length) b
L
(In.)
36
48
56
66
b

Branches: EDB, EDG, or EDJ, 60 A maximum. See Digest page 9-15 for
branch circuit breaker catalog numbers, List Prices and terminal data.
Cabinet: Front—Screw cover. Box—galvanized steel with removable
endwalls.
Gutters:
• 100 A—4 in. min. mains end, 3 in. min.opposite mains
• 225 A—10 in. min. mains end, 5 in. min. opposite mains

8.625 in. x 5 in.
Catalog Number
MTX836
MTX848
MTX856
MTX866

$ Price

S/N
Terminals

Catalog
Number

42

MPX81542

590.
651.
753.
753.

Cable Troughs and Pull Boxes

Cable Troughs (L=Length) c

Pull Boxes with Solid Neutral
$ Price

8.625 in. x
5.625 in.
Catalog
Number d
NTX836
NTX848
NTX856
NTX866

L
(In.)

479.

36
48
56
66

Cable troughs are standard with a trough barrier.
c
d

Pull Boxes with Solid Neutral

$ Price
590.
651.
753.
753.

S/N
Terminals

Catalog
Number

42

MPX81542

$ Price

479.

Cable troughs are standard with a trough barrier.
Box width = 8.625 in.; width at front, including flange, is 9.625 in..

20 in.

15 in.

Cable
Trough
Length

Solid
Neutral
Bar

Pull Box
(Cover Removed)
Cable
Trough

Panel
Height
Column
Width
Lighting
Panelboard
8 5⁄8 in.

9-18

PE1A

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

NQ/NF Factory Assembled Single Row (Column Width) Panelboards
Class 1640 / Refer to Catalog 1670CT0701, 1640CT0801

www.schneider-electric.us

NQ Single Row (Column-Width)—240 Vac Bolt-On Factory Assembled Pricing
Table 9.89:

Base Price with Solid Neutral
$ Price
Main Lugs
2-Pole

Main Circuit Breaker (Circuit Breaker Interrupt Rating—see Digest pages 7-2 through 7-5

3-Pole

100 A

720.

832.

225 A

772.

912.

Circuit Breaker

2-Pole

QOB
QB
QD
QB
QD

3-Pole

1254.

Circuit Breaker

2-Pole

—
—
QG
—
QG

—
—
—
—
—

1562.
2800.
3434.
2800.
3434.

—
—
—
—

PANELBOARDS

Mains Rating

3-Pole
—
—
4090.
—
4090.

Note: Copper bus —standard.
Equipment Ground Bar $ Price adder—$38.00.
Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder—$52.00.

Branch Circuit Breakers (price per breaker)
$ Price

Circuit Breaker
Ampere Rating

1-Pole 120 Vac

2-Pole 120/240 Vac

Space Only
All Space Only Except Below
28.
10,000 AIR—Branch Circuit Breakers—QOB, QOB-H
15–60 A
68.
10,000 AIR—Qwik-Guard™—Class A—QOB-GFI
15–30 A
272.
40–60 A
—
Specialty Branch Circuit Breakers (10,000 AIR)
For High Intensity Discharge Lighting—QO-HID, QOB-HID
15–30 A
78.
40–50 A
78.
High Magnetic Trip (For applications subject to high initial inrush)—QO-HM, QOB-HN
15–20 A
68.
—
Provides 30 mA Equipment Protection—QO-EPD, QOB-EPD
15–30 A
462.
(High Interrupting Capacity)
22,000 AIR Branch Circuit Breakers—QO-VH, QOB-VH
15–30 A
92.
35–60 A
—
22,000 AIR—Qwik-Guard—Class A—QO-VHGFI, QOB-VHGFI
15–30 A
294.
—

2-Pole 240 Vac

9

Table 9.90:

3-Pole 240 Vac

58.

58.

86.

134.

260.

352.

488.
488.

—
—

—
—

148.
148.

—
—

—

—

—

828.

—

—

212.
212.

—
—

376.

462.
462.

—

—

NF Single Row (Column-Width)—480Y/277 Vac 3Ø4W Bolt-on Factory Assembly Pricing
Table 9.91:

Base Price with Solid Neutral
Main Circuit Breaker (Circuit Breaker Interrupt Rating —see Digest pages 7-3 through 7-4

Main Lugs

Standard IC

Mains
Rating
2-Pole

3-Pole

Circuit Breaker

HIC

$ Price
2-Pole

3-Pole

Extra HIC
$ Price

Circuit
Breaker

2-Pole

3-Pole

—
FA
—
2184.
FH
—
100 A
—
1074.
—
2842.
—
HD
HG
125 A
—
—
3222.
—
150 A
—
HD
—
3222.
HG
—
1272.
225 A
—
JD
—
4784.
JG
—
Note: Copper bus—standard.
Copper Neutral $ Price adder—$132.00.
Equipment Ground Bar $ Price adder—$38.00.
Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder—$52.00.

Table 9.92:

3044.
3792.
4172.
4172.
5982.

I-Limiter™

$ Price

Circuit
Breaker

2-Pole

—

3-Pole

—
—
—
—
—

HJ
HJ
JJ

—
4374.
4754.
4754.
8902.

Circuit
Breaker
—
FI
KI

$ Price
2-Pole

3-Pole

—
—
—
—
—

KI

—
7392.
13150.
13150.

Branch Circuit Breakers (price per breaker)
$ Price

Circuit Breaker
Ampere Rating

Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR
@480Y/277 Vac ED Bolt-on Branch
1-Pole

15–60 A
Space Only

Table 9.93:

2-Pole
192.
42.

3-Pole
442.
84.

High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR
@480Y/277 Vac EG Bolt-on Branch
1-Pole

748.
126.

2-Pole
324.
42.

3-Pole
746.
84.

Extra High Interrupting 100,000 AIR @ 65,000 AIR @
480Y/277 Vac EJ Bolt-on Branch
1-Pole

1264.
126.

2-Pole
518.
42.

3-Pole
1196.
84.

2024.
126.

EDB-EPD Equipment Protection Device Branch Circuit Breakers
$ Price

Circuit Breaker
Ampere Rating

Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR
@480Y/277 Vac ED Bolt-on Branch
1-Pole

15–60 A

© 2012 Schneider Electric
All Rights Reserved

1472.

2-Pole

3-Pole

—

—

High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR
@480Y/277 Vac EG Bolt-on Branch
1-Pole
1596.

PE-1

Discount
Schedule

2-Pole

3-Pole

—

—

Extra High Interrupting 100,000 AIR @ 65,000 AIR @
480Y/277 Vac EJ Bolt-on Branch
1-Pole
1788.

2-Pole

3-Pole

—

—

9-19

I-Line™ and QMB
Panelboards

Pricing Procedure and Examples
Class 2110, 4620 / Refer to Catalog 2110CT9701, 4620CT9601
www.schneider-electric.us

9

I-Line Merchandised Pricing Procedure

PANELBOARDS

1.

Select the appropriate branch circuit breakers and accessories based on the required ampacity and AIR ratings from
Digest pages 9-24 through 9-30.

2.

Determine the total mounting inches required by the branch circuit breakers. Pay close attention to the interior types and
any branch mounting restrictions by referring to panel layouts on Digest pages 9-21 and 9-22. For example, larger frame
circuit breakers may mount in only one side of the panel due to physical sizes. Therefore, for larger size branches, you may
only be able to consider one half of the total mounting inches available.

3.

Select proper main lug interior or main circuit breaker interior from Digest page 9-21 or 9-22 based on the mains ampacity
and branch requirements from step 2.

4.

Select blanks from the Accessories table on Digest page 9-23 as required to cover unused mounting space.

5.

Select appropriate box and front from Digest page 9-21 or 9-22 to accommodate panel interior selected in step 3.

6.

Apply appropriate discount schedule.

Table 9.94:

I-Line Merchandised Pricing Example

600 Vac, 3Ø3W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door.
Description

Catalog No.

Digest Page No.

400 Amp MLO Interior
4 Piece Surface Trim Without Door
Type 1 Enclosure
(8) 60/3
one 100/2
one 4.5 in. Blanks
one 1.5 in. Blank

HCM32734
HCM73TS
HC3273B
FA36060
FA26100AC
HNM4BL
HNM1BL

9-21
9-21
9-21
9-25
9-25
9-23
9-23

$ Price
2408.
699.
243.
7764.
947.
126.
44.

Total Price

12231.

I-Line Factory Assembled Pricing Procedure
1.

Select price for main lugs or main circuit breaker from Base Price tables on Digest page 9-31. Include solid neutral and
ground bar when required.

2.

List branch circuit breakers and determine total mounting inches required. Include space only charge and mounting inches
as required. Price branches from Digest page 9-32.

3.

If total space required exceeds the maximum listed, price as two or more panels and add price for sub-feed lugs, so
installer can cable between sections.

4.

Add price for special features from Digest page 9-34.

5.

For complete price, total all prices. Order panel by description.

6.

Apply appropriate discount schedule.

Table 9.95:

I-Line Factory Assembled Pricing Example

600 Vac, 3Ø3W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door.
Description

Digest Page No.

400 A MLO Base Price
(8) 60/3
one 100/2
(3) 250/3

9-31
9-32
9-32
9-32

$ Price
2799.
12072.
1446.
17100.

Total Price

33417.

QMB Factory Assembled
QMB Panelboards—Method of Pricing
1.

Make a sketch with main lugs or main switch at the top or bottom.

2.

List required branch devices (switches and circuit breaker units). Include ampere rating, number of poles, and unit
mounting height from the appropriate table on Digest pages 9-35 and 9-36.

3.

30–60 twin units are the same price as 600 V 60–60 twin units.

4.

30–100 and 60–100 twin units are the same price as 600 V 100–100 twin units.

5.

List solid neutral from Digest page 9-36 if required. No unit mounting height is required.

6.

List mains ampere rating, voltage, number of poles, and unit mounting space from the appropriate table on 9-36.

7.

If total unit mounting height of branch devices exceeds maximum mounting space of the mains, price as two or more
panelboards, adding sub-feed lugs or feed-thru lugs from the appropriate table on Digest page 9-36.

8.

Insert at the right of each item the price from the appropriate table, including any accessories. The sum will be the
complete panelboard price including the cabinet.

9.

Specify H, R, or J fuse clips.

Table 9.96:

QMB Factory Assembled Pricing Example

600 Vac, 3Ø3W, 400 A, Fusible 10k AIR, Type 1 Enclosure
Branches

Digest Page No.

400 A MLO Base Price
(4) 60/3
one 100/3
one 30/3

9-36
9-36
9-36
—
Total Price

9-20

Example pricing only

Discount
Schedule

$ Price
2016.
4338.
3411.
—
9765.

© 2012 Schneider Electric
All Rights Reserved

I-Line™ Merchandised
Panelboards

600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701

www.schneider-electric.us

Table 9.97:

TYPE HCN

1⁄2 Total
Breaker
Mounting
Space
Each
Side

600 A Max. Main Lugs
or
400 A Max. Main Breaker

S
N

Box Size:
26 in. Wide, 6.5 in. Deep

TYPE HCM
250 A max. branch circuit
breaker
FA, FH, FY, FI, QB, QD, QG, QJ,
HD, HG, HJ, HL, JD, JG, JJ, JL

QB, QD
QG, QJ

QB, QD
QG, QJ
FA, FH
FI, FY

FA, FH
FI, FY

HD, HG
HJ, HL

HD, HG
HJ, HL

JD, JG
JJ, JL

JD, JG
JJ, JL

1⁄2 Total
Breaker
Mounting
Space
Each
Side

S
N

800 A Max. Main Lugs
or
800 A Max. Main Breaker

Box Size:
32 in. Wide, 8.25 in. Deep

TYPE HCP-SUh
800 A max. main circuit breaker
600 A max. branch circuit
breaker
FY, FA, FH, FI, KI, LA, LD, LG,
LJ, LL, LH, LC, LX, LI, LXI, LE,
MG, MJ, PG, PJ, PL, PGC, PJC,
PLCj, QB, QD, QG, QJ, HD,
HG, HJ, HL, JD, JG, JJ, JL

FY, FA, FH, FI
HD, HG, HJ, HL
QB, QD, QG, QJ
JD, JG, JJ, JL, KI

MG, MJ, PG, PJ, PL
PGC, PJC, PLC

S
N

800 A Max. Main Lugs
or
800 A Max. Main Breaker

a
b
c
d
e
f
g
h

j
k
l
m

© 2012 Schneider Electric
All Rights Reserved

4 Piece Trim
Without Door b

Trim With Door

Catalog
Number

Catalog
Number

Catalog
Number

$
Price

$
Price

$
Price

NEMA
3R/5/12 d
(Includes Front)

Type 1

Catalog
Number

$
Price

Catalog
Number

$
Price

Box Height (In.)

Type
3R/
5/12
$ Price

Box c

HCN Main Lugs Only
3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i
225 A 2171. 4004.
HCN14522N
1593.
27 400 A 2195. 4028.
HCN14524
1617.
HCN52T( )
335.
HCN52T( )D
411. HC2652B
600 A 2392. 4225.
HCN14526
1814.
225 A 2674. 4402.
HCN23652N
1991.
45 400 A 2702. 4430.
HCN23654
2019.
HCN65T( )
440.
HCN65T( )D
530. HC2665B
600 A 2960. 4688.
HCN23656
2277.
225 A 3135. 4709.
HCN32742N
2298.
63 400 A 3156. 4730.
HCN32744
2319.
HCN74T( )
594.
HCN74T( )D
717. HC2674B
600 A 3396. 4970.
HCN32746
2559.
225 A 3548. 6233.
HCN41832N
2552.
81 400 A 3564. 6249.
HCN41834
2568.
HCN83T( )
753.
HCN83T( )D
890. HC2683B
600 A 3824. 6509.
HCN41836
2828.
225 A 4175. 6767.
HCN50922N
3086.
99 400 A 4341. 6933.
HCN92T( )
846.
HCN92T( )D
1001. HC2692B
HCN50924
3252.
600 A 4434. 7026.
HCN50926
3345.
HCN Main Circuit Breaker e k
Includes 3-pole, vertically mounted main circuit breaker—Suitable for use as service equipment
27 400 A 6649. 8377. HCN14654M
5966.
100 A 3860. 5588. HCN18651MN
3177.
HCN65T( )
440.
HCN65T( )D
530. HC2665B
36
225 A 5303. 7031. HCN18652MN
4620.
45 400 A 7287. 8861. HCN23744M
6450.
100 A 4323. 5897. HCN27741MN
3486.
HCN74T( )
594.
HCN74T( )D
717. HC2674B
54
225 A 5759. 7333. HCN27742MN
4922.
225 A 6068. 8753. HCN32832MN
5072.
63
HCN83T( )
753.
HCN83T( )D
890. HC2683B
400 A 7836. 10521. HCN32834M
6840.
81 400 A 8154. 10746. HCN41924M
7065.
HCN92T( )
846.
HCN92T( )D
1001. HC2692B
90 225 A 6590. 9182. HCN45922MN
5501.
HCM Main Lugs Only
3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i
225 A 2279. 4566. HCM14482N
1644.
400 A 2404. 4691.
HCM14484
1769.
27
HCM48T( )
392.
HCM48T( )D
483. HC3248B
600 A 3175. 5462.
HCM14486
2540.
800 A 3709. 5996.
HCM14488
3074.
225 A 2795. 5717. HCM23642N
2036.
400 A 2891. 5813.
HCM23644
2132.
45
HCM64T( )
516.
HCM64T( )D
633. HC3264B
600 A 3530. 6452.
HCM23646
2771.
800 A 4041. 6963.
HCM23648
3282.
225 A 3263. 6002. HCM32732N
2321.
400 A 3350. 6089.
HCM32734
2408.
63
HCM73T( )
699.
HCM73T( )D
864. HC3273B
600 A 3921. 6660.
HCM32736
2979.
800 A 4644. 7383.
HCM32738
3702.
225 A 4205. 7918. HCM50912N
2966.
400 A 4281. 7994.
HCM50914
3042.
99
HCM91T( )
996.
HCM91T( )D
1217. HC3291B
3347.
600 A 4586. 8299.
HCM50916
800 A 5321. 9034.
HCM50918
4082.
HCM Main Circuit Breaker e k
Includes 3-pole, vertically mounted main circuit breaker—Suitable for use as service equipment.
27 400 A 7563. 10485. HCM14644M
6804.
HCM64T( )
516.
HCM64T( )D
633. HC3264B
225 A 5582. 8504. HCM18642MN
4823.
36 600 A 11648. 10706. HCM18736MP 10706.
HCM73T( )
699.
HCM73T( )D
864. HC3273DB9m
800 A 14549. 13607. HCM18738MP 13607.
45 400 A 8007. 10746. HCM23734M
7065.
HCM73T( )
699.
HCM73T( )D
864. HC3273B
54 225 A 5969. 8708. HCM27732MN
5027.
600 A 12377. 11138. HCM36916MP 11138.
72
HCM91T( )
996.
HCM91T( )D
1217. HC3291DB9m
800 A 15431. 14192. HCM36918MP 14192.
81 400 A 9315. 13028. HCM41914M
8076.
HCM91T( )
996.
HCM91T( )D
1217. HC3291B
HCP-SU g Universal Single Row Main Lugs or Main Circuit Breaker k
3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i
54
800
5858. 9466. HCP54868SU
4514. HC2686T( )4P 1101. HC2686T( )HRf 1658. HC2686DB

i

Box Size:
26 in. Wide, 9.5 in. Deep

Type 1
$ Price

Front a
Interior Assembly
(Less Branch
Circuit Breakers)

243. HC2652WP

2411. 52

243. HC2665WP

2411. 65

243. HC2674WP

2411. 74

243. HC2683WP

3681. 83

243. HC2692WP

3681. 92

243. HC2665WP

2411. 65

243. HC2674WP

2411. 74

243. HC2683WP

3681. 83

243. HC2692WP

3681. 92

243. HC3248WP

2922. 48

243. HC3264WP

3681. 64

243. HC3273WP

3681. 73

243. HC3291WP

4952. 91

243. HC3264WP

3681. 64

243.

Use HCP

243. HC3273WP
243.

Use HCP

—

—

3681. 73
—

—

243. HC3291WP

4952. 91

243. HC2886WP

4952. 86

Add “F” for flush mount, “S” for surface mount.
Add-on door kit available from Peru. Example: For HCM48TS surface trim kit, order HCM48DS door kit.
For Type 1 applications, order interior, front, and box. For Type 3R/5/12 applications, order interior and box only. The front is included with the box.
Remove drain screws for Type 3R rating.
Bottom feed standard.
Hinged trim with door.
For main lugs panel, order sub-feed lug kit and back-feed as main lugs.
For main circuit breaker panel, order plug-on I-Line type PG, PJ, PL, MG, or MJ circuit breakers from 9-28 through 9-30 and backfeed as the main breaker
(order solid neutral from 9-22).
Suitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided
and the panelboard is not used as a lighting and appliance branch circuit panelboard.
PG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80%
and 100% rated. “C” suffix denotes a 100% rating.
Circuit breaker interrupt ratings, starting on Digest page 7-2.
I-Line Surgelogic SPD not available.
DB9 box is 9.5 inches deep.

PE1A

Discount
Schedule

9-21

PANELBOARDS

FA, FH
FY
HD, HG
HJ, HL

Complete
Surface $ Price
(4 Piece Trim)
(Less Branch
Circuit
Breakers)

9

FA, FH
FY
HD, HG
HJ, HL

Mains Ampere Rating

QB, QD
QG, QJ

Total Circuit Breaker
Mounting Space (In.)

225 A max. (240 V max.) branch
circuit breaker QB, QD, QG, QJ
150 A max. branch circuit
breaker FA, FH, FY, HD, HG, HJ,
HL l

QB, QD
QG, QJ

Interiors, Boxes and Fronts

(100 A and 225 A interiors include solid neutral, all others without solid neutral. Order solid neutral from 9-23)

I-Line™ Merchandised
Panelboards

600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701
www.schneider-electric.us

TYPE HCP

PANELBOARDS

800 A max. branch
circuit breaker
FAa, FH, FI, FY, QB, QD, QG,
QJ, HD, HG, HJ, HL, JD, JG, JJ,
JL, KI, LA, LD, LG, LJ, LL, LH,
LC, LI, LX, LXI, LE, MG, MJ,
PG, PJ, PL, PGC, PJC, PLCb
QB, QD
QG, QJ
FA, FH, FY
HD, HG
HJ, HL
FI, KI, JD
JG, JJ, JL

FA, FH, FY
HD, HG
HJ, HL
QB, QD
QG, QJ
FI, KI, JD
JG, JJ, JL
LD, LG, LJ
LL, LA, LH
LC, LI, LX
LXI, LE
MG, MJ, PG,
PJ, PL, PK, PGC
PJC, PKC, PLC

1⁄2 Total
Breaker
Mounting
Space
Each
Side

S
N

1200 A Max. Main Lugs
or
800 A Max. Main Breaker

Box Size:
42 in. Wide, 9.5 in. Deep
a

FA and JDA circuit breakers
with field installable ground
fault kits may be mounted in
type HCP, HCP-SU, and
HCR-U panelboards as
shown, and require L-frame
mounting space.
PG, PJ, and PL circuit
breakers are available
with both thermalmagnetic equivalent and
Micrologic trip. The
Micrologic circuit breakers
are available 80% and
100% rated. “C” suffix
denotes a 100% rating.

b

TYPE HCR-U Universal
Mains
1200 A max. branch
circuit breaker
FAc, FH, FI, FY, QB, QD, QG,
QJ, HD, HG, HJ, HL, JD, JG, JJ,
JL, KI, LA, LD, LG, LJ, LL, LH,
LC, LI, LX, LXI, LE, MG, MJ,
PG, PJ, PL, PGC, PJC, PLC,
RGC, RJC, RLCde

1⁄2

Total
Breaker
Mounting
Space
Each
Side

FA, FH, FY
HD, HG
HJ, HL

QB, QD
QG, QJ

QB, QD
QG, QJ

FA, FH, FY
HD, HG
HJ, HL

FI, KI, JD
JG, JJ, JL

FI, KI, JD
JG, JJ, JL

Total
Circuit
Breaker
Mtg.
Space
(In.)

(1200 A Interiors Include solid neutral, all others without solid neutral.
Order solid neutral from 9-23.)
Max.
No. of
LC, MJ,
PL, RL
Circuit
Breakers

Mains Amp.
Rating

9

Table 9.98:

1200 A Max. Main Lugs or
1200 A Max. Main Breaker

S/N

Box Size:
44 in. Wide, 9.5 in. Deep
c

d

e

9-22

FA and JDA circuit
breakers with field
installable ground fault kits
may be mounted in type
HCP, HCP-SU, and HCRU panelboards as shown,
and require L-frame
mounting space.
When RL main circuit
breakers with equipment
ground fault are applied on
a 3Ø4W system, order
solid neutral catalog
number HCR12SNCT.
The HCR12SNCT
includes a neutral current
transformer.
PG, PJ, and PL circuit
breakers are available
with both thermalmagnetic equivalent and
Micrologic trip. The
Micrologic circuit breakers
are available 80% and
100% rated. “C” suffix
denotes a 100% rating.

Catalog
Number

Type 1

$
Price

Box h

Box
Height
(In.)

4 Piece Trim
Without Door g

Trim With Door

Catalog
Number

$
Price

Catalog
Number

HCW50T( )

606.

HCW50T( )D

743. HC4250DB

243.

50

HCW59T( )

671.

HCW59T( )D

827. HC4259DB

243.

59

HCW68T( )

846.

HCW68T( )D

1052. HC4268DB

243.

68

HCW86T( )

1101.

HCW86T( )D

1344. HC4286DB

243.

86

HCW68T( )

846.

HCW68T( )D

1052. HC4268DB

243.

68

HCW86T( )

1101.

HCW86T( )D

1344. HC4286DB

243.

86

243.

86

$
Price

Catalog
Number

$
Price

HCR-U Universal Main Lugs or Main Circuit Breakerj—3-pole
Suitable for use as service equipment when provided with a main circuit breaker.
For Main Lugs panel, order sub-feed lug kit catalog number S33930 and back feed as main lugs.
For Main Circuit Breaker panel, order plug-on I-Line type PG, PJ, PL, RGC, RJC, or RLCk circuit breakers from pages 9-27 through 9-29,
and back feed as the main circuit breaker. (Order solid neutral separately)
108 l
f
g
h
i
j
k
l
m

1200

6PL or 3RLC

12557.

HCR548612U

11213.

Table 9.99:

1101.

HCR86T( )D

1344. HC4486DB

Circuit Breaker / Sub-feed Lug Kit Mounting Space Requirement

FY
FA, FH
FA, FH
FA, FH, SL-100
FI
HD, HG
HD, HG
HJ, HL
QB, QD, QG, QJ

Maximum
Ampacity
30 A
100 A

150 A
225 A

No. of
Poles
1
1
2
3
2, 3
2
3
2, 3
2

Inch Mounting
Requirements
1.5
1.5
3
4.5
4.5
3
4.5
4.5
3

Type of Circuit Breaker
QB, QD, QG, QJ
JD, JG, JJ, JL, KI, SL250
LA, LH, SL400
LD, LG, LJ, LL
LC, LI, LXI
MG, MJ, MA, MH, SL800, PGC, PJC, PLC
PG, PJ, PL, S33931
RG, RJ, RL, RGC, RJC, RLC, S33930

Table 9.100: Main Circuit Breaker Interiors —Standard Frame
Types n
Main Circuit
Breaker Ampacity

Panelboard
Type

Factory Supplied
Main Circuit Breaker

100
225

HCN
HCN, HCM
HCN
HCM

FA36100
JDA36225
LAP36400MB
LAP36400MB
MGP36600
or
MGP36800

400
600
or
800
n

HCR86T( )m

Add “F” for flush mount, “S” for surface mount.
Add-on door kit available. Example: For HCW50TS trim kit, order HCW50D door kit.
See Digest page 9-23 for 42 in. wide weatherproof enclosures.
Suitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided
and the panelboard is not used as a lighting and appliance branch circuit panelboard.
Circuit breaker interrupt ratings, starting on Digest page 7-2.
When RL main circuit breakers with equipment ground fault are applied on a 3Ø4W system, order solid neutral catalog number HCR12SNCT.
The HCR12SNCT includes a neutral current transformer.
15 in. of mounting space is taken up by the back fed main lug kit or RG, RJ, RL main circuit breaker, leaving 93 in. of branch circuit breaker mounting space.
Add-on door kit available. Example: For HCR86TS trim kit, order HCW86D door kit.

Type of Circuit Breaker

MG, MJ
PG, PJ, PK,
PL, PGC, PJC,
PKC, PLC
RG, RJ, RK,
RL, RGC, RJC
RKC, RLC

Front f
Interior Assembly
(Less Branch Circuit Breakers)

HCP Main Lugs Only—3-pole
Suitable for use as service equipment when provided with a main circuit breaker. i
400
2751.
HCP14504
1902.
600
3513.
HCP14506
2664.
27
1PL
800
4521.
HCP14508
3672.
1200
6365.
HCP145012N
5516.
400
3212.
HCP23594
2298.
600
3860.
HCP23596
2946.
45
2PL
800
4874.
HCP23598
3960.
1200
7133.
HCP235912N
6219.
400
3795.
HCP32684
2706.
600
4476.
HCP32686
3387.
63
3PL
800
5309.
HCP32688
4220.
1200
7763.
HCP326812N
6674.
400
4716.
HCP50864
3372.
600
5208.
HCP50866
3864.
99
5PL
800
6194.
HCP50868
4850.
1200
8529.
HCP508612N
7185.
HCP Main Circuit Breakerj—Includes 3-pole
Vertically mounted main circuit breaker—Suitable for use as service equipment.
600
12179.
HCP18686M
11090.
36
2LC
800
15399.
HCP18688M
14310.
600
12987.
HCP36866M
11643.
72
4LC
800
16296.
HCP36868M
14952.

LD, LG, LJ
LL, LA, LH
LC, LI, LX
LXI, LE

Complete
Surface
$ Price
(4 Piece Trim)
(Less Branch
Breakers)

HCM, HCP

Maximum
Ampacity
225 A
250 A
400 A
600 A
600 A

No. of
Poles
3

2, 3

Inch Mounting
Requirements
4.5
4.5
6
6
7.5

800 A

9

1200 A
1200 A

15

Table 9.101: Standard Copper Bus Interiors
Type

Main Ampacity

HCN
HCM, HCP-SU
HCP, HCR-U

600
800
800 and Above

Note: Merchandised copper interiors are not available in all ampacities. For
example, if the application calls for a HCN 225 A copper bus interior,
order an HCN 600 A interior .

Circuit breaker interrupt ratings, starting on Digest page 7-2.

PE1A

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

I-Line™ Merchandised
Panelboards

Accessories
Class 690, 2110 / Refer to Catalog 2110CT9701

www.schneider-electric.us

Table 9.102: I-Line Merchandised Panelboard Accessories

Equipment Ground Bar

800 A

Solid Neutral

1200 A
1200 A, for use with HCR-U universal panel only
1200 A, Including neutral CT for 3Ø4W systems
Equipment Ground Bar Kits—HCN
HCM, HCP, HCR-U
Blank Extensions (For replacement purposes)
1.5 in. for mounting on wide side of I-Line panelboard (minimum order 3) e
4.5 in. for mounting on wide side of I-Line panelboard (minimum order 5) e
1.5 in. for mounting on narrow side of I-Line panelboard (minimum order 3) e
4.5 in. for mounting on narrow side of I-Line panelboard (minimum order 5) e
4.5 in. for mounting on wide side of I-Line panelboard (minimum order 5) e
4.5 in. for mounting on narrow side of I-Line panelboard (minimum order 5) e
a
b
c
d
e

Table 9.103: Blank Extensions

All applications, except Powerpact H/J
with Micrologic trip unit 5/6
All applications, except Powerpact H/J
with Micrologic trip unit 5/6
Only Powerpact H/J circuit breakers
with Micrologic trip unit 5/6
Only Powerpact H/J circuit breakers
with Micrologic trip unit 5/6

HLW1BL
HLW4BL
HLN1BL
HLN4BL
HLW4EBL
HLN4EBL

252.00
333.00
464.00
717.00
1151.00
1269.00
843.00
1151.00
1269.00
33.80
104.00
14.30
25.20
14.30
25.20
25.20
25.20

Used on Type HCN, HCM.
Used on 400 A, 600 A, 800 A, and 1200 A HCP (main lugs), and 600 A and 800 A (main circuit breaker).
Used on Type HCP-SU.
Used on Type HCR-U.
Blank extension pricing is per unit. Multiply the list price by the quantity ordered. Note minimum order quantity.

Table 9.104: Panelboard Adapter Kits
Circuit
Breaker
Mounting
Ht.

Application

HC2SN
HC4SNa, HCW4SNb
HC6SNa, HCW6SNb
HC8SNa, HCW8SNb
HCPSU8SNc
HCPSU8SNCTc
HCW12SNb
HCWM12SNd
HCR12SNCTd
PK27GTA
PK32DGTA

$ Price
14.30
25.20

1.5 in.
4.5 in.
1.5 in.
4.5 in.

Branch
Circuit
Side

Catalog
Number

4.5 in.

HLW1BL
Wide Side
HLW4BL
HLN1BL
Narrow
Side
HLN4BL
Narrow HLN4EBL
Side

4.5 in.

Wide Side HLW4EBL

I-Line Panelboard Type

Crimp Lug Adapter Kits f

HCN
HCN400VCA
HCN600VCA
—
—

400 A
600 A
800 A
1200 A
f
g

HCP, HCR-U g
HCW400VCA
HCW600VCA
HCW800VCA
HCW1200VCA

HCM
HCM400VCA
HCM600VCA
HCM800VCA
—

$ Price
96.
197.
284.
491.

For use with MLO panel, order VCEL lugs seperately.
Not for use with P- or R-frame circuit breakers or sub-feed kits S33930 or S33931.

Table 9.105: Type 3R/5/12 Enclosures
Catalog Number

Interior Type

HC4250WP
HC4259WP
HC4268WP
HC4286WP
HC4486WP

HCP
HCP
HCP
HCP
HCR-U

Dimensions (In.)

$ Price

H
50
59
68
86
86

4952.
4952.
4952.
4952.
4952.

W
42
42
42
42
44

D
12.95
12.95
12.95
12.95
14.50

Table 9.106: Box Extensions
Catalog Number

Interior Type

Extension

HC2609DEX (F or S)

HCP-SU

9 in.

$ Price
552.

HC2609EX (F or S)

HCN

9 in.

552.

HC3209EX (F or S)

HCM

9 in.

552.

HC4212DEX (F or S)

HCP

12 in.

641.

HC4406DEX (F or S)

HCR-U

6 in.

552.

HC4412DEX (F or S)

HCR-U

12 in.

641.

Blank Extensions
Table 9.107: Sub-feed Lug Kits hi
Ampere
Rating
100 A
250 A
250 A
400 A

In. (mm)
4.5 114 SL100
4.5 114 SL250
4.5 114 SL250
6
152 SL400j
9

229

1200 A
1200 A

9
15

229 S33931
381 S33930

SL800

435.
435.
435.
585.
1731.
1731.
3500.
3500.

Max. Short Circuit System Ratings
RMS Symmetrical Amperes
240 Vac
65,000
125,000
200,000
65,000
65,000
125,000
100,000
125,000

480 Vac
25,000
100,000
200,000
35,000
65,000
100,000
65,000
100,000

600 Vac
18,000
50,000
100,000
25,000
25,000
50,000
25,000
50,000

Protected by
Circuit Breaker
FH
JL
KI
LH
MJ
LL
MJ, PJ
RL

For Use in I-Line
Panelboard Types
HCN, HCM, HCP, HCP-SU
HCM, HCP, HCP-SU
HCP, HCP-SU
HCM, HCP, HCP-SU
HCP, HCP-SU, HCR-U

Plug-on in same manner as a branch circuit breaker
For other ratings, See the I-Line Information Manual, #80043-309-xx.
SL400 cannot be used in HCM panelboards due to inadequate wire bending space.

Table 9.108: Sub-feed Lug kit terminal data
Catalog No.
(Prefix)
SL100
SL250
SL400
SL800
S33931
S33930

For Surgelogic™ I-Line plug-on SPD unit pricing and
information, see Digest pages 6-3 and 6-4.
For field-installable I-Line door kits, see the
Supplemental and Obsolescence Digest, Section 4.
k
© 2012 Schneider Electric
All Rights Reserved

Catalog
Number $ Price

800 A

h
i
j

Sub-feed Lug Kits

Height

No.
Poles
3
3
3
3
3
3

Ampere
Rating
100 A
250 A
400 A
800 A
1200 A
1200 A

Std. Lug Kit
Catalog No.
AL100FA
—
AL400LA
AL900MA
AL1200P24K
AL1200R53K

Standard Lug Wire Size k
#14–1/0 AWG Cu or #12–1/0 AWG Al
#4 AWG–300 kcmil
one #1 AWG–600 kcmil or two #1 AWG–250 kcmil
(3) #3/0 AWG–500 kcmil
(4) #3/0 AWG–500 kcmil
(4) #3/0 AWG–600 kcmil

Unless otherwise specified, wire sizes apply to both aluminum and copper conductors.

9-23

PANELBOARDS

Blank Fillers

Catalog No.
HNM1BL
HNM4BL

9

Description
Blank Fillers—1.5 in. (minimum order 3) e
Blank Fillers—4.5 in. (minimum order 5) e
Solid Neutral Assemblies
225 A
400 A
600 A

Circuit Breakers

F-frame, PowerPact D-frame for I-Line™ Panelboards and Switchboards
Class 650, 651
www.schneider-electric.us

9

Table 9.109: QO™ Distribution Panel—240 Vac Max. Only Mounts in Type
HCN, HCM, HCP, HCP-SU, or HCR-U I-Line panelboards, 30 A
max. branch circuit breaker. Order QO plug-on circuit breakers
from page 9-34.
Maximum No. 1-pole Phase
QO Circuit Breakers Connection

PANELBOARDS

6
6
6
6
a

AB
BC
AC
ABC

Mounting
Height
In.
4.5
4.5
4.5
4.5

2-pole
Catalog
Number

mm
114
114
114
114

3-pole
Catalog
Number

HQO206AB
HQO206BC
HQO206AC
—

Table 9.114: F-frame—100 A, Thermal-magnetic (240 Vac)
Ampere
Rating

$ Price
a

—
—
—
HQO306

369.
369.
369.
369.

Includes (5) QO1DB dummy circuit breakers.

FA/FH, 1-pole
1.5 in (38 mm)
Mounting Height

FA/FH, 3-pole
4.5 in (114 mm)
Mounting Height

FA/FH, 2-pole
3 in (76 mm)
Mounting Height

Table 9.110: Example: FJA, 20 A 1-pole, 277 Vac and 70 A 2- and 3-pole QB 240
Vac. Use phase option number for HD, HG, HJ, HL, JD, JG, JJ, JL,
MG, and MJ.
Phase
Option
Number
1
3
5
1
2
3
4
5
6
Standard b
6
b

Phase
Connection

1-pole

2-pole

3-pole

A
B
C
AB
AC
BA
BC
CA
CB
ABC
CBA

FJA140201
FJA140203
FJA140205
—
—
—
—
—
—
—
—

—
—
—
QBA220701
QBA220702
QBA220703
QBA220704
QBA220705
QBA220706
—
—

—
—
—
—
—
—
—
—
—
QBA32070
QBA320706

1-pole

2-pole

3-pole

—
—
—
FA24030AB
FA24030AC
FA24030BC
—
—

—
—
—
—
—
—
FA34030
FA34030CBA

Table 9.112: Interrupt Ratings (kA)
240 V
277 V
480 V
600 V

FA (240 V)
10
—
—
—

FA (480 V)
18 (1P), 25 (2, 3P)
18
18
—

FJ
65
65
—
—

F-frame accessories . . . . . . . . . starting on Supplemental Digest page 3-24
F-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54
F-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-51

PowerPact™ D-frame Mission Critical Circuit Breakers
When the D-frame Mission Critical circuit breaker is used as a main circuit
breaker with QO branch circuit breakers, the D-frame MC will remain closed
during any fault that occurs downstream of the QO circuit breaker up to 30kA
at 208Y/120 Vac.
Table 9.113: PowerPact D-frame, 150–600 A–Mission Critical
Circuit Breaker
Cat.alog Number c
DJA32150W
DJA32250W
DJA32400W
DJA32600W

Continuous Current
Rating
150 A
250 A
400 A
600 A

Terminal Wire Range (AWG/kcmil) $ Price
#2-600 Cu or #2-500 Al
(2) 2/0-350 Cu or (2) 2/0-500Al

10867.
10867.
10867.
17148.

c
D-frame circuit breakers 400 A and below are 100% rated.
D-frame accessories, lugs . . . . . starting on Supplemental Digest page 3-27
D-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55

9-24

600

850

1450
1700

600

850

1450
1700

Terminal
Wire
Range

Standard Interrupting
Catalog Number $ Price
FA22015(
FA22020(
FA22025(
FA22030(
FA22035(
FA22040(
FA22045(
FA22050(
FA22060(
FA22070(
FA22080(
FA22090(
FA22100(
FA32015
FA32020
FA32025
FA32030
FA32035
FA32040
FA32045
FA32050
FA32060
FA32070
FA32080
FA32090
FA32100

)
)
)
)
)
)
)
)
)
)
)
)
)

AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
398.

AL100FA
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al
617.

572.

AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al

572.

AL100FA
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al

572.
780.

AL100FA
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al

780.

AL100FA
#14–#1/0 AWG Cu

1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase
connection letters as a suffix.

AC Magnetic Standard Interrupting Extra High Interrupting Terminal Wire Range
Ampere Trip Settings
Rating
Catalog
Catalog
FY/FA FJ/FC Lugs
Hold
Trip
$ Price Number
$ Price
Number
Lugs
1-pole, 277 Vac, 125 Vdc e
15 A
FY14015( )f
FJA14015( )
AL50FA
AL30FD
#14-#4
#12–#6
20 A
FY14020( )f
FJA14020( )
275
600
149.
651. AWG Cu, or AWG Al, or
25 A
FY14025( )f
FJA14025( )
#12-#4
#14–#6
30 A
FY14030( )f
FJA14030( )
AWG Al
AWG Cu
35 A
FA14035( )g
FJA14035( )
40 A
FA14040( )g
FJA14040( )
400
850
302.
651.
45 A
FA14045( )g
FJA14045( )
AL100FA AL100FD
50 A
FA14050( )g
FJA14050( )
#14–#1/0 #12–#2/0
AWG Al
60 A
FA14060( )g
FJA14060( )
651. AWG Cu or
or
800
1450 FA14070( )g
302. FJA14070( )
70 A
720. #12–#1/0 #14–#2/0
AWG Al
AWG Cu
80 A
FA14080( )g
—
—
90 A
FA14090( )g
—
—
900
1700
302.
100 A
FA14100( )g
—
—
2-pole, 480 Vac, 250 Vdc efg
15 A
FA24015( )
—
—
AL50FA CU30FA4
#14–#4
20 A
FA24020( )
—
—
one #14–
275
600
651.
AWG
Cu or #10 AWG
25 A
FA24025( )
—
—
#12–#4
Cu only
30 A
FA24030( )
—
—
AWG Al
35 A
FA24035( )
—
—
40 A
FA24040( )
—
—
400
850
651.
45 A
FA24045( )
—
—
AL100FA AL100FA4
#14–#3
50 A
FA24050( )
—
—
#14–#1/0 one
Cu
AWG Cu or AWG
60 A
FA24060( )
651.
—
—
or
#12–#1/0 one #12–#1
800
1450 FA24070( )
70 A
—
—
833.
AWG Al
AWG Al
80 A
FA24080( )
—
—
90 A
FA24090( )
—
—
900
1700
833.
100 A
FA24100( )
—
—
3-pole, 480 Vac, 250 Vdc e
15 A
FA34015
—
—
AL50FA CU30FA4
#14–#4
20 A
FA34020
—
—
one #14–
275
600
833.
AWG
Cu or #10 AWG
25 A
FA34025
—
—
#12–#4
Cu only
30 A
FA34030
—
—
AWG Al
35 A
FA34035
—
—
40 A
FA34040
—
—
400
850
833.
45 A
FA34045
—
—
AL100FA AL100FA4
50 A
FA34050
—
—
#14–#1/0 one #14–#3
Cu
AWG Cu or AWG
60 A
FA34060
833.
—
—
or
#12–#1/0 one #12–#1
800
1450
70 A
FA34070
—
—
996.
AWG Al
AWG Al
80 A
FA34080
—
—
90 A
FA34090
—
—
900
1700
996.
100 A
FA34100
—
—
e
f
g

DE2

Trip

Table 9.115: F-frame—100 A, Thermal-magnetic (480 Vac)

Table 9.111: Example: FA, 30 A, 480 Vac. Use phase option letters for FH, FI, KI,
LA, LH, LC, and LI.

FA14035A
FA14035B
FA14035C
—
—
—
—
—

Hold
2-pole, 240 Vac d
15 A
20 A
275
25 A
30 A
35 A
40 A
400
45 A
50 A
60 A
70 A
800
80 A
90 A
900
100 A
3-pole, 240 Vac
15 A
20 A
275
25 A
30 A
35 A
40 A
400
45 A
50 A
60 A
70 A
800
80 A
90 A
900
100 A
d

The absence of a phase option number after a 3-pole catalog number will result in an ABC
phase connection.

Phase
Option Letter
A
B
C
AB
AC
BC
ABC
CBA

AC Magnetic
Trip Settings

Discount
Schedule

1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase
connection letters as a suffix.
Rated 277 Vac 15 and 20 A FY circuit breakers are rated for switching duty (SWD). 15, 20,
25, and 30 A FA I-Line circuit breakers are also available (no SWD rating).
Rated 277 Vac, 125 Vdc, except FY circuit breakers, which have no dc rating.
15–30 A circuit breakers suitable for use with 60 oC or 75 oC conductors. 35–100 A circuit
breakers are suitable for use with 75 oC conductors.
© 2012 Schneider Electric
All Rights Reserved

Circuit Breakers

F-frame, PowerPact Q-frame for I-Line™ Panelboards and Switchboards
Class 650, 734, 820

www.schneider-electric.us

Table 9.116: F-frame—100 A, Thermal-magnetic (600 Vac)
Standard Interrupting

FI36100
2- and 3-pole
4.5 in (114 mm)
Mounting Height

Catalog Number

$ Price

—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—

850

1450
1700

Catalog Number
FH16015(
FH16020(
FH16025(
FH16030(
FH16035(
FH16040(
FH16045(
FH16050(
FH16060(
FH16070(
FH16080(
FH16090(
FH16100(

)
)
)
)
)
)
)
)
)
)
)
)
)

FH26015(
FH26020(
FH26025(
FH26030(
FH26035(
FH26040(
FH26045(
FH26050(
FH26060(
FH26070(
FH26080(
FH26090(
FH26100(

)
)
)
)
)
)
)
)
)
)
)
)
)

Terminal
Wire
Range

Current Limiting

$ Price

507.

507.
507.
563.
563.

Catalog Number

$ Price

—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—

AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al

AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al

a
600

850

1450
1700

600

850

1450
1700

FA26015(
FA26020(
FA26025(
FA26030(
FA26035(
FA26040(
FA26045(
FA26050(
FA26060(
FA26070(
FA26080(
FA26090(
FA26100(

)
)
)
)
)
)
)
)
)
)
)
)
)

780.

780.
780.
947.
947.

FA36015
FA36020
FA36025
FA36030
FA36035
FA36040
FA36045
FA36050
FA36060
FA36070
FA36080
FA36090
FA36100

971.

971.
971.
1163.
1163.

1214.

1214.
1214.
1452.
1452.

FH36015
FH36020
FH36025
FH36030
FH36035
FH36040
FH36045
FH36050
FH36060
FH36070
FH36080
FH36090
FH36100

1446.

1446.
1446.
1632.
1632.

—
FI26020(
—
FI26030(
—
FI26040(
—
FI26050(
FI26060(
FI26070(
FI26080(
FI26090(
FI26100(

—
2763.
—
2763.
—
2763.
—
2763.

)
)
)
)
)
)
)
)
)

2763.

AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al

AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al

2763.

—
FI36020
—
FI36030
—
FI36040
—
FI36050
FI36060
FI36070
FI36080
FI36090
FI36100

—
3459.
—
3459.
—
3459.
—
3459.
3459.

AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al

AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al

3459.

a
1- and 2-pole circuit breaker catalog numbers are completed by adding the required connection letters as a suffix, See Digest page 9-24.
NOTE: As of January 1st, FI breakers will only fit on the wide side of I-Line panelboards.

Table 9.117: PowerPact™ Q-frame b— 225 A, Thermal-magnetic (240 Vac)
QB/QD/QG/QJ
Mounting Height:
2-pole—3 in (76 mm)
3-pole—4.5 in (114 mm)

AC Magnetic
Trip Settings
Hold
Trip
2-pole, 240 Vac c
70 A
80 A
1000 1800
90 A
100 A
110 A
125 A
150 A
1200 2400
175 A
200 A
225 A
3-pole, 240 Vac d
70 A
80 A
1000 1800
90 A
100 A
110 A
125 A
150 A
1200 2400
175 A
200 A
225 A
Ampere
Rating

b
c
d

"B" Interrupting
Catalog Number
QBA22070(
QBA22080(
QBA22090(
QBA22100(
QBA22110(
QBA22125(
QBA22150(
QBA22175(
QBA22200(
QBA22225(

)
)
)
)
)
)
)
)
)
)

QBA32070(
QBA32080(
QBA32090(
QBA32100(
QBA32110(
QBA32125(
QBA32150(
QBA32175(
QBA32200(
QBA32225(

)
)
)
)
)
)
)
)
)
)

"D" Interrupting

$ Price

600.

600.

1913.

1913.

Catalog Number
QDA22070(
QDA22080(
QDA22090(
QDA22100(
QDA22110(
QDA22125(
QDA22150(
QDA22175(
QDA22200(
QDA22225(

)
)
)
)
)
)
)
)
)
)

QDA32070(
QDA32080(
QDA32090(
QDA32100(
QDA32110(
QDA32125(
QDA32150(
QDA32175(
QDA32200(
QDA32225(

)
)
)
)
)
)
)
)
)
)

"G" Interrupting

$ Price

1202.

1202.

2069.

2069.

Catalog Number
QGA22070(
QGA22080(
QGA22090(
QGA22100(
QGA22110(
QGA22125(
QGA22150(
QGA22175(
QGA22200(
QGA22225(

)
)
)
)
)
)
)
)
)
)

QGA32070(
QGA32080(
QGA32090(
QGA32100(
QGA32110(
QGA32125(
QGA32150(
QGA32175(
QGA32200(
QGA32225(

)
)
)
)
)
)
)
)
)
)

"J" Interrupting

$ Price

1593.

1593.

2835.

2835.

Catalog Number
QJA22070(
QJA22080(
QJA22090(
QJA22100(
QJA22110(
QJA22125(
QJA22150(
QJA22175(
QJA22200(
QJA22225(

)
)
)
)
)
)
)
)
)
)

QJA32070(
QJA32080(
QJA32090(
QJA32100(
QJA32110(
QJA32125(
QJA32150(
QJA32175(
QJA32200(
QJA32225(

)
)
)
)
)
)
)
)
)
)

$ Price

1992.

1992.

3245.

3245.

Replacement lugs are not available on QB, QD, QG, or QJ circuit breakers. Lugs for QB, QD, QG, or QJ circuit breakers accept one #4 AWG–300 kcmil.
No accessories are available for PowerPact Q Frame breakers.
2-pole QB, QD, QG, and QJ circuit breakers are completed by adding the required phasing numbers as indicated in the parentheses, See Digest page 9-24.
3-pole QB, QD, QG, and QJ circuit breakers for ABC phasing are complete without additional phasing number. For CBA phasing, complete the catalog
number by inserting the number “6” in the parentheses.

Table 9.118: Interrupt Ratings (kA)
240 V
480 V
600 V
e

FA
25
18
14

FH
25 (1P 35–100 A), 65 (1P 15–30 A, 2P, 3P)
25 (2, 3P)
18 (2, 3P)

100

QB
10
—
—

QD
25
—
—

QG
65
—
—

QJ e
100
—
—

3-pole QJ circuit breakers are rated at 208Y/120 Vac only.

F-frame accessories . . . . . . . . . starting on Supplemental Digest page 3-24
F-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-54
F-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-51

© 2012 Schneider Electric
All Rights Reserved

FI
200

DE2

Discount
Schedule

Q-frame accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-38
. . . . . . . . . . . . . . . . . . . . . . . . . . .starting on Supplemental Digest page 3-24
Q-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54
Q-frame optional lugs . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-29

9-25

9

30 A
35 A
40 A
400
45 A
50 A
60 A
70 A
800
80 A
90 A
900
100 A
2-pole, 600 Vac, 250 Vdc
15 A
20 A
275
25 A
30 A
35 A
40 A
400
45 A
50 A
60 A
70 A
800
80 A
90 A
900
100 A
3-pole, 600 Vac, 250 Vdc
15 A
20 A
275
25 A
30 A
35 A
40 A
400
45 A
50 A
60 A
70 A
800
80 A
90 A
900
100 A

High Interrupting

PANELBOARDS

AC Magnetic
Trip Settings
Hold
Trip
1-pole, 277 Vac, 125 Vdc a
15 A
20 A
275
600
25 A
Ampere
Rating

Circuit Breakers

H- and J-frame for I-Line™ Panelboards and Switchboards
Class 612
www.schneider-electric.us

9

Table 9.119: H-frame 150 A Thermal-Magnetic UL Current-Limitinga Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unitb Suitable for Reverse
Connectionb
Current
Rating @
40o C

Fixed AC Magnetic
Trip

Interrupting Rating (2nd Letter of Catalog Number)
G
Ja
La
$ Price
80% Rated
80% Rated
80% Rated
80% Rated
D

Cat. No.c

PANELBOARDS

Hold
Trip
H-frame, 150A 2P, 600 Vac 50/60 Hz, 250 Vdca
15 A
350 A
750 A
H( )A26015( )
899.
1338.
1589.
20 A
350 A
750 A
H( )A26020( )
899.
1338.
1589.
25 A
350 A
750 A
H( )A26025( )
899.
1338.
1589.
30 A
350 A
750 A
H( )A26030( )
899.
1338.
1589.
35 A
400 A
850 A
H( )A26035( )
899.
1338.
1589.
40 A
400 A
850 A
H( )A26040( )
899.
1338.
1589.
45 A
400 A
850 A
H( )A26045( )
899.
1338.
1589.
50 A
400 A
850 A
H( )A26050( )
899.
1338.
1589.
60 A
800 A
1450 A
H( )A26060( )
899.
1338.
1589.
70 A
800 A
1450 A
H( )A26070( )
1088.
1559.
1824.
80 A
800 A
1450 A
H( )A26080( )
1088.
1559.
1824.
90 A
800 A
1450 A
H( )A26090( )
1088.
1559.
1824.
100 A
800 A
1700 A
H( )A26100( )
1088.
1559.
1824.
110 A
900 A
1700 A
H( )A26110( )
2195.
3212.
4671.
125 A
900 A
1700 A
H( )A26125( )
2195.
3212.
4671.
150 A
900 A
1700 A
H( )A26150( )
2195.
3212.
4671.
H-frame 150A 3P, 600 Vac 50/60 Hz, 250 Vdc
15 A
350 A
750 A
H( )A36015
1124.
1575.
1988.
20 A
350 A
750 A
H( )A36020
1124.
1575.
1988.
25 A
350 A
750 A
H( )A36025
1124.
1575.
1988.
30 A
350 A
750 A
H( )A36030
1124.
1575.
1988.
35 A
400 A
850 A
H( )A36035
1124.
1575.
1988.
40 A
400 A
850 A
H( )A36040
1124.
1575.
1988.
45 A
400 A
850 A
H( )A36045
1124.
1575.
1988.
50 A
400 A
850 A
H( )A36050
1124.
1575.
1988.
60 A
800 A
1450 A
H( )A36060
1124.
1575.
1988.
70 A
800 A
1450 A
H( )A36070
1361.
1772.
2225.
80 A
800 A
1450 A
H( )A36080
1361.
1772.
2225.
90 A
800 A
1450 A
H( )A36090
1361.
1772.
2225.
100 A
800 A
1700 A
H( )A36100
1361.
1772.
2225.
110 A
900 A
1700 A
H( )A36110
2730.
3779.
5432.
125 A
900 A
1700 A
H( )A36125
2730.
3779.
5432.
150 A
900 A
1700 A
H( )A36150
2730.
3779.
5432.
a
2 pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix see Table 9.128.

Terminal
Wire Range

2364.
2483.
2483.
2483.
2483.
2483.
2483.
2483.
2483.
2681.
2681.
2681.
2681.
5699.
5699.
5699.

AL150HD
14–3/0 AWG
Al or Cu

2993.
2993.
2993.
2993.
2993.
2993.
2993.
2993.
2993.
3243.
3243.
3243.
3243.
6951.
6951.
6951.

AL150HD
14–3/0 AWG
Al or Cu

Table 9.120: J-frame 250 A Thermal-Magnetic UL Current-Limitinga Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unitb Suitable for Reverse
Connectionb
Current
Rating @
40oC

Adjustable AC Magnetic
Trip

D

Cat. No.c

Interrupting Rating (2nd Letter of Catalog Number)
G
Ja
La
$ Price
80% Rated
80% Rated
80% Rated

Low
High
80% Rated
J-frame 250A 2P, 600 Vac 50/60 Hz, 250 Vdca
150 A
750 A
1500 A
J( )A26150( )
2283.
3372.
4904.
5985.
175 A
875 A
1750 A
J( )A26175( )
2283.
3372.
4904.
5985.
200 A
1000 A
2000 A
J( )A26200( )
2283.
3372.
4904.
5985.
225 A
1125 A
2250 A
J( )A26225( )
2283.
3372.
4904.
5985.
250 A
1250 A
2500 A
J( )A26250( )
3138.
4463.
6536.
7338.
J-frame 250A 3P, 600 Vac 50/60 Hz, 250 Vdc
150 A
750 A
1500 A
J( )A36150
2867.
3968.
5705.
7299.
175 A
875 A
1750 A
J( )A36175
2867.
3968.
5705.
7299.
200 A
1000 A
2000 A
J( )A36200
2867.
3968.
5705.
7299.
225 A
1125 A
2250 A
J( )A36225
2867.
3968.
5705.
7299.
250 A
1250 A
2500 A
J( )A36250
3936.
5252.
7599.
9173.
a
2 pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix see Table 9.128.

Ra

Terminal
Wire Range

80% Rated
AL175JD
4–4/0 AWG Al or Cu
AL250JD
3/0 AWG–350 kcmil
Al or Cu

—
—
—
—
—

AL175JD
4–4/0 AWG Al or Cu
AL250JD
3/0 AWG–350 kcmil
Al or Cu

9676.
9676.
9676.
9676.
11729.

Table 9.121: H-frame 150 A and J-frame 250 A Electronic Trip UL Current-Limitinga Circuit Breakers
(600 Vac) With Factory Sealed Trip Unitb Suitable for Reverse Connection d
Electronic Trip Unit
Type

Function

Trip Unit

Sensor
Rating

D
Cat. No.c
80%
Rated

Interrupting Rating (2nd Letter of Catalog Number)
G
Ja
La
$ Price
80%
80%
80%
Rated
Rated
Rated

Ra
Terminal
80%
Rated

600 Vac, 50/60 Hz, 3P
LI

3.2g

Micrologic
Standard

Micrologic
Ammeter
Micrologic
Energy
Micrologic
Ammeter
Micrologic
Energy
a
b
c
d
e
f
g

9-26

LSI

3.2Sg

LSI

5.2A

LSI

LSIG

LSIG

5.2E

6.2A

6.2E

60 A
100 A
150 A
250 A
60 A
100 A
150 A
250 A
60 A
100 A
150 A
250 A
60 A
100 A
150 A
250 A
60 A
100 A
150 A
250 A
60 A
100 A
150 A
250 A

H( )A36060U31X
H( )A36100U31X
H( )A36150U31X
J( )A36250U31X
H( )A36060U33X
H( )A36100U33X
H( )A36150U33X
J( )A36250U33X
H( )A36060U43X
H( )A36100U43X
H( )A36150U43X
J( )A36250U43X
H( )A36060U53X
H( )A36100U53X
H( )A36150U53X
J( )A36250U53X
H( )A36060U44X
H( )A36100U44X
H( )A36150U44X
J( )A36250U44X
H( )A36060U54X
H( )A36100U54X
H( )A36150U54X
J( )A36250U54X

1316.
1569.
2911.
3120.
1512.
1765.
3107.
3398.
2143.
2396.
3738.
4299.
2523.
2776.
4118.
4840.
2902.
3156.
4497.
5381.
3282.
3535.
4877.
5921.

1743.
1962.
3965.
4226.
1939.
2159.
4161.
4505.
2570.
2789.
4792.
5406.
2950.
3169.
5172.
5947.
3330.
3549.
5551.
6487.
3709.
3929.
5931.
7028.

2224.
2382.
5626.
5970.
2420.
2578.
5823.
6249.
3051.
3209.
6453.
7150.
3431.
3589.
6833.
7691.
3811.
3969.
7213.
8231.
4190.
4349.
7593.
8772.

3173.
3490.
7288.
7715.
3370.
3686.
7484.
7994.
4001.
4317.
8115.
8895.
4380.
4697.
8495.
9436.
4760.
5077.
8875.
9976.
5140.
5456.
9254.
10517.

4171.
4591.
9631.
10102.
4393.
4813.
9853.
10420.
5185.
5653.
10836.
11561.
5883.
6333.
11342.
12413.
6423.
6873.
11864.
13157.
6963.
7413.
12386.
13900.

AL150HDe
AL250JDf
AL150HDe
AL250JDf
AL150HDe
AL250JDf
AL150HDe
AL250JDf
AL150HDe
AL250JDf
AL150HDe
AL250JDf

Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting.
See Supplemental Digest pages 3-2 and 3-3 for circuit breakers with field-interchangeable trip units
To complete catalog number, replace the blank with the appropriate rating (D, G, J, L).
For applications requiring communications, see Digest page 7-49.
AL150HD wire range is 14–3/0 AWG Al or Cu.
AL250JD wire range is 3/0 AWG–350 kcmil Al or Cu. For smaller wire range (4–4/0 AWG Al or Cu), replace the lug’s wire binding screws with the larger binding screws provided.
3P circuit breakers with this trip unit can be used for 2P applications.

DE2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Circuit Breakers

K-, PowerPact H-, J-, L-frame for I-Line™ Panelboards and Switchboards
Class 825, 0612

www.schneider-electric.us

Table 9.122: K-frame—250 A, Thermal-magnetic, Current Limiting (600 Vac)
Current Limiting

Low

High

2-pole, 600 Vac, 250 Vdc a
110 A
550
125 A
625
150 A
750
175 A
875
200 A
1000
225 A
1125
250 A
1250

1100
1250
1500
1750
2000
2250
2500

KI26110(
KI26125(
KI26150(
KI26175(
KI26200(
KI26225(
KI26250(

3-pole, 600 Vac, 250 Vdc
110 A
125 A
150 A
175 A
200 A
225 A
250 A

1100
1250
1500
1750
2000
2250
2500

KI36110
KI36125
KI36150
KI36175
KI36200
KI36225
KI36250

Terminal
Wire Range

$ Price

)
)
)
)
)
)
)

6633.
6633.
6633.
6633.
6633.
6633.
7704.

AL250KA
one #4 AWG–
350 kcmil
Al or Cu
AL250KI
one #1/0 AWG–
350 kcmil Al or Cu

8375.
8375.
8375.
8375.
8375.
8375.
9267.

AL250KA
one #4 AWG–
350 kcmil
Al or Cu
AL250KI
one #1/0 AWG–
350 kcmil Al or Cu

2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See Digest page 9-24.

9

a

550
625
750
875
1000
1125
1250

Catalog Number

PANELBOARDS

AC Magnetic Trip Settings

Ampere
Rating

KI36250
2- and 3-pole
4.5 in (114 mm)
Mounting Height

J-Frame Mission Critical Circuit Breaker
Table 9.123: J-frame 250 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac) With Factory Sealted Trip Units Suitable for Reverse Connectiona
Electronic Trip
Unit Type

Trip
Continuous
Function Trip Unit
Current

D Interrupting
Cat. No.
JDA34250WU31X
JDA34250WU33X
JDA34250WU43X
JDA34250WU53X
JDA34250WU44X
JDA34250WU54X

G Interrupting
$ Price
3619.
3931.
4939.
5544.
6148.
6753.

Standard
LI
3.2 W
250
Standard
LSI
3.2S-W
250
High Perf. Ammerter
LSI
5.2A-W
250
High Perf. Energy
LSI
5.2E-W
250
High perf. Ammerter
LSIG
6.2A-W
250
High Perf. Energy
LSIG
6.2E-W
250
a
Standard rated (80%). Not available in 100% rated.
b
AL250JD terminal wire range is (1) 3/0 AWG–350 kcmil Al or Cu.

Cat. No.
JGA34250WU31X
JGA34250WU33X
JGA34250WU43X
JGA34250WU53X
JGA34250WU44X
JGA34250WU54X

J Interrupting

$ Price
4857.
5169.
6176.
6782.
7386.
7991.

Cat. No.
JJA34250WU31X
JJA34250WU33X
JJA34250WU43X
JJA34250WU53X
JJA34250WU44X
JJA34250WU54X

L Interrupting

$ Price
6808.
7119.
8127.
8732.
9336.
9942.

Cat. No.
JLA34250WU31X
JLA34250WU33X
JLA34250WU43X
JLA34250WU53X
JLA34250WU44X
JLA34250WU54X

$ Price
8759.
9071.
10079.
10684.
11288.
11893.

Terminal
AL250JDb
AL250JDb
AL250JDb
AL250JDb
AL250JDb
AL250JDb

L-Frame Mission Critical Circuit Breaker
Table 9.124: L-frame 600 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac) With Factory Sealted Trip Units Suitable for Reverse Connectiona
Electronic Trip
Unit Type

Trip
Continuous
Function Trip Unit
Current

D Interrupting
Cat. No.
LDA34250WU31X
LDA34400WU31X
LDA34600WU31X
LDA34250WU33X
LDA34400WU33X
LDA34600WU33X
LDA34400WU43X
LDA34600WU43X
LDA34400WU53X
LDA34600WU53X
LDA34400WU44X
LDA34600WU44X
LDA34400WU54X
LDA34600WU54X

G Interrupting

$ Price
5991.
5991.
8684.
6656.
6656.
9349.
7674.
10366.
8791.
11485.
9911.
12604.
11029.
13722.

Cat. No.
LGA34250WU31X
LGA34400WU31X
LGA34600WU31X
LGA34250WU33X
LGA34400WU33X
LGA34600WU33X
LGA34400WU43X
LGA34600WU43X
LGA34400WU53X
LGA34600WU53X
LGA34400WU44X
LGA34600WU44X
LGA34400WU54X
LGA34600WU54X

250
Standard
LI
3.3 W
400
600
250
Standard
LSI
3.3S-W
400
600
400
High Perf. Ammeter
LSI
5.3A-W
600
400
High Perf. Energy
LSI
5.3E-W
600
400
High Perf. Ammeter
LSIG
6.3A-W
600
400
High Perf. Energy
LSIG
6.3E-W
600
a
Standard rated (80%). Not available in 100% rated.
b
AL400L61K3 terminal wire range is (1) #2 AWG–500 kcmil Al or #2 AWG–600 kcmil Cu..
c
AL600LF52K3 terminal wire range is (2) #3/0 AWG–500 kcmil Al or Cu.

$ Price
6291.
6291.
9126.
6990.
6990.
9826.
8062.
10896.
9238.
12074.
10417.
13251.
11594.
14429.

J Interrupting

L Interrupting

Cat. No.
$ Price
LJA34250WU31X 10299.
LJA34400WU31X 10299.
LJA34600WU31X 12733.
LJA34250WU33X 10999.
LJA34400WU33X 10999.
LJA34600WU33X 13433.
LJA34400WU43X 12070.
LJA34600WU43X 14503.
LJA34400WU53X 13247.
LJA34600WU53X 15681.
LJA34400WU44X 14426.
LJA34600WU44X 17139.
LJA34400WU54X 15602.
LJA34600WU54X 18036.

Cat. No.
LLA34250WU31X
LLA34400WU31X
LLA34600WU31X
LLA34250WU33X
LLA34400WU33X
LLA34600WU33X
LLA34400WU43X
LLA34600WU43X
LLA34400WU53X
LLA34600WU53X
LLA34400WU44X
LLA34600WU44X
LLA34400WU54X
LLA34600WU54X

$ Price
11998.
11998.
14263.
12698.
12698.
14962.
13769.
16033.
14946.
17210.
16125.
18388.
17301.
19566.

Terminal
AL400L61K3b
AL600LF52K3c
AL400L61K3b
AL600LF52K3c
AL600LF52K3c
AL600LF52K3c
AL600LF52K3c
AL600LF52K3c

Table 9.125: PowerPact™ H-, J-, and L-frame Automatic Molded Case Switches, 600 Vac
Circuit
Ampere
Breaker Poles Rating

G Withstand

L Withstand

R Withstand

Trip
Cat. No.
$ Price Point
Cat. No.
$ Price Trip Point
Cat. No.
$ Price Trip Point
150 A
HGA26000S15( )
1349. 2250 A
HLA26000S15
1590. 2250 A
—
—
—
2a
175 A
JGA26000S17( )
1827. 3125 A
JLA26000S17
1980. 3125 A
—
—
—
250 A
JGA26000S25( )
1827. 3125 A
JLA26000S25
1980. 3125 A
—
—
—
H-frame
J-frame
150 A
HGA36000S15
1799. 2250 A
HLA36000S15
1988. 2250 A
HRA36000S15
2295. 2250 A
3
175 A
JGA36000S17
2286. 3125 A
JLA36000S17
2475. 3125 A
JRA36000S17
2860. 3125 A
250 A
JGA36000S25
2286. 3125 A
JLA36000S25
2475. 3125 A
JRA36000S25
2860. 3125 A
400 A
LGA36000S40X
4572. 4800 A LLA36000S40X
4972. 4800 A
LRA36000S40X
5688. 4800 A
L-frame
3
600 A
LGA36000S60X
5065. 6600A LLA36000S60X
5465. 6600 A
LRA36000S60X
6220. 6600 A
a
2-pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix, see Table 9.128.

Table 9.126: KI Interrupt Ratings (kA)
V
240
480
600

Table 9.127: Interrupt Ratings (kA)
KI
200
200
100

240 V
480 V

D
25
18

G
65
35

K-frame accessories . . . . . . . . . .starting on Supplemental Digest page 3-25
K-frame dimensions. . . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-33
K-frame optional lugs. . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-28
H-, J-, and L-frame accessories . . . . . . . . . . . . .starting on Digest page 7-36
H-, J-, and L-frame dimensions. . . . . . . . . . . . . .starting on Digest page 7-54
H-, J-, and L-frame optional lugs. . . . . . . . . . . . . . . . . . . . . . Digest page 7-39

© 2012 Schneider Electric
All Rights Reserved

DE2

Discount
Schedule

Terminal

Wire Range

—
—
—
AL150HD
AL175JD
AL250JD
AL150HD
AL250JD

—
—
—
14 AWG–3/0 AWG Al/Cu
4–4/0 AWG Al/Cu
3/0 AWG–350 kcmil Al/Cu
AL600LS52K3
(2) 2/0 AWG–500 kcmil Al/Cu

Table 9.128: Phase Options—Example HDA26150( )
J
100
65

L
125
100

Phase
Option
Number
1
2
3
4
5
6
Standard
6

Phase
Connection

2-pole

3-pole

AB
AC
BA
BC
CA
CB
ABC
CBA

HDA261501
HDA261502
HDA261503
HDA261504
HDA261505
HDA261506
—
—

—
—
—
—
—
—
JDA34250WU31X
JDA34250WU31X6

9-27

Circuit Breakers

LA Mission Critical for I-Line™ Panelboards and Switchboards
Class 660, 665, 670, 830
www.schneider-electric.us

9

LA Mission Critical Circuit Breakers
The LA High Magnetic Withstand MC Circuit Breakers are designed to trip at a higher magnetic trip level (18–20 times
handle rating) than typical molded case circuit breakers (MCCBs) (which trip at 5–10 times the handle rating). The high
magnetic withstand value of these LA circuit breakers allow the downstream branch circuit breaker to clear the fault.
Table 9.129: L-frame—400 A, I-Line™ LA/LH MC High Magnetic Withstand Circuit Breaker For Mission Critical Loads

PANELBOARDS

Ampere
Rating

AC Magnetic Level
Factory Set a

Standard Interrupting

Hold

Cat. No.

Trip

LA/LH MC Circuit Breaker, 3P, 480 Vac
200 A
3400 A
4000 A
225 A
3825 A
4500 A
250 A
4250 A
5000 A
400 A
a

6000 A

7200 A

High Interrupting

$ Price

Cat. No.

LA34200MC
LA34225MC
LA34250MC

5571.
5571.
5681.

LH34200MC
LH34225MC
LH34250MC

LA34400MC

6941.

LH34400MC

Terminal

$ Price

Cat. No.

8771.
8771. AL250LAMC
8882.
10142.

AL400LA

Wire Range

(1) 250–350 kcmil Al
(1) 3/0 AWG–350 kcmil Cu
(1) 1 AWG–600 kcmil Al or
(2) 1 AWG–250 kcmil Al

AC magnetic setting tolerances are +0 -25% from maximum value shown.

Table 9.130: L-frame—400 A, Thermal-magnetic (600 Vac)
Ampere
Rating

LA/LH
2- and 3-pole
6 in (152 mm)
Mounting Height

Low

2-pole, 600 Vac, 250 Vdc b
125 A
625
150 A
750
175 A
875
200 A
1000
225 A
1125
250 A
1250
300 A
1500
350 A
1750

High

Standard Interrupting
Catalog Number

High Interrupting

$ Price

Catalog Number

$ Price

1250
1500
1750
2000
2250
2500
3000
3500

LA26125(
LA26150(
LA26175(
LA26200(
LA26225(
LA26250(
LA26300(
LA26350(

)
)
)
)
)
)
)
)

4053.
4053.
4053.
4053.
4053.
4053.
4053.
4053.

LH26125(
LH26150(
LH26175(
LH26200(
LH26225(
LH26250(
LH26300(
LH26350(

)
)
)
)
)
)
)
)

6762.
6762.
6762.
6762.
6762.
6762.
6762.
6762.

2000

4000

LA26400( )

4053.

LH26400( )

6762.

3-pole, 600 Vac, 250 Vdc
125 A
625
150 A
750
175 A
875
200 A
1000
225 A
1125
250 A
1250
300 A
1500
350 A
1750
400 A
2000

1250
1500
1750
2000
2250
2500
3000
3500
4000

LA36125
LA36150
LA36175
LA36200
LA36225
LA36250
LA36300
LA36350
LA36400

4944.
4944.
4944.
4944.
4944.
4944.
4944.
4944.
4944.

LH36125
LH36150
LH36175
LH36200
LH36225
LH36250
LH36300
LH36350
LH36400

8145.
8145.
8145.
8145.
8145.
8145.
8145.
8145.
8145.

400 A

LI
2- and 3-pole
7.5 in (190 mm)
Mounting Height

AC Magnetic
Trip Settings

Terminal
Wire
Range

AL400LA
one #1 AWG–600 kcmil or
two #1 AWG–250 kcmil
AL or Cu

AL400LA
one #1 AWG–600 kcmil or
two #1 AWG–250 kcmil
AL or Cu

Table 9.131: L-frame—600 A, Thermal-magnetic (600 Vac)c
Ampere
Rating

LC
2- and 3-pole
7.5 in (190 mm)
Mounting Height

AC Magnetic Trip Settings
Low

2-pole, 600 Vac b
300 A
1500
350 A
1750
400 A
2000
450 A
2250
500 A
2500
600 A
3000
3-pole, 600 Vac
300 A
1500
350 A
1750
400 A
2000
450 A
2250
500 A
2500
600 A
3000
b
c

Extra High Interrupting
Catalog
Number

High

LC26300(
LC26350(
LC26400(
LC26450(
LC26500(
LC26600(

3200

4200

)
)
)
)
)
)

8312.

8691.

LC36300
LC36350
LC36400
LC36450
LC36500
LC36600

3200

4200

Current Limiting

$ Price

9234.

9657.

Catalog
Number
LI26300(
LI26350(
LI26400(
LI26450(
LI26500(
LI26600(
LI36300
LI36350
LI36400
LI36450
LI36500
LI36600

$ Price

)
)
)
)
)
)

Terminal
Wire
Range

9563.
AL600LI5
two #4/0 AWG–500 kcmil
AL or Cu
13949.

10673.
AL600LI5
two #4/0 AWG–500 kcmil
AL or Cu
15498.

2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See Digest page 9-24.
Type LC and LI circuit breakers are NOT recommended for use on single-motor branch circuits.

L-frame acccessories. . . . . . . . . starting on Supplemental Digest page 3-24
L-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54
L-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-53

Table 9.132: Interrupt Ratings (kA)
240 V
480 V
600 V

9-28

LA

LH

LC

LI

42
30
22

65
35
25

100
65
35

200
200
100

DE2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

Circuit Breakers

L- and PowerPact M-frame for I-Line™ Panelboards and Switchboards
Class 612, 661

www.schneider-electric.us

Table 9.133: L-frame 600 A Circuit Breakers with Lugs and Factory-Sealed Electronic Trip Units Suitable for Reverse Connectiona
Interrupting Rating (2nd Letter of Catalog Number)
Electronic Trip Unit
Trip
Function Unit

Sensor
Rating

Jc

G

Catalog
Numberb

Lc

Rc
Terminal

$ Price
80%

100%

80%

100%

80%

100%

80%

100%

80%

100%

600 Vac, 53/60 Hz, 3P
250 A

L( )A36250U31X

5122.

5943.

5376.

6240.

8773.

10214.

10213.

11899.

11745.

13745.

400 A
600 A

L( )A36400U31X
L( )A36600U31X

5122.
7404.

5943.
—

5376.
7779.

6240.
—

8773.
10836.

10214.
—

10213.
12132.

11899.
—

11745.
13952.

13745. AL600LF52K3f
—

250 A
3.3Sd 400 A
600 A

L( )A36250U33X

5686.

6506.

5969.

6833.

9366.

10808.

10806.

12493.

12427.

14449.

L( )A36400U33X
L( )A36600U33X

5686.
7968.

6506.
—

5969.
8372.

6833.
—

9366.
11429.

10808.
—

10806.
12725.

12493.
—

12427.
14634.

14449.
—

5.3A

400 A
600 A

L( )A36400U43X
L( )A36600U43X

6548.
8830.

7368.
—

6877.
9279.

7740.
—

10274.
12336.

11715.
—

11714.
13632.

13400.
—

13471.
15677.

15523.
—

LSI

5.3E

400 A
600 A

L( )A36400U53X
L( )A36600U53X

7495.
9778.

8316.
—

7874.
10277.

8738.
—

11271.
13334.

12713.
—

12711.
14630.

14398.
—

14618.
16825.

16705. AL600LF52K3f
—

Micrologic
Ammeter

LSIG

6.3A

400 A
600 A

L( )A36400U44X
L( )A36600U44X

8444.
10726.

9264.
—

8873.
11275.

9736.
—

12270.
14332.

13711.
—

13710.
15628.

15396.
—

15767.
17972.

17887.
—

Micrologic
Energy

LSIG

6.3E

400 A
600 A

L( )A36400U54X
L( )A36600U54X

9392.
11674.

10212.
—

9870.
12273.

10734.
—

13267.
15329.

14709.
—

14707.
16626.

16394.
—

16913.
19120.

19069.
—

LI

Micrologic
Standard

LSI

Micrologic
Ammeter

LSI

Micrologic
Energy

Interrupt Ratings (kA)
G

J

Lh

65

100

125

480 V

35

65

100

600 V i

18

25

25

240 V

h

AL400L61K3e

L interrupting rating is not
available in M-frame.
600 V interrupt ratings
not available for D-frame.

Table 9.134: PowerPact M-frame: with ET1.0 Factory – sealed trip unit (not field adjustable)—800 A j
Ampere
Rating
300 A
350 A
400 A
450 A
500 A
600 A
700 A
800 A
300 A
350 A
400 A
450 A
500 A
600 A
700 A
800 A

3-pole, 600 Vac,
50/60 Hz

i

AL400L61K3e

See Supplemental Digest page 3-4 for circuit breakers with field-interchangeable trip units.
For 100% rated circuit breakers (250 A and 400 A only), add a “C” in the 9th character place (for example, LRA36400CU31X).
Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting.
3P circuit breakers with this trip unit can be used for 2P applications.
AL400L61K3 terminal wire ranges are (1) 2 AWG–600 kcmil Cu or (1) 2 AWG–500 kcmil Al.
AL600LFS52K3 terminal wire range is (2) 3/0 –500 kcmil.
For applications requiring communications, see Digest page 7-43.

2-pole, 600 Vac,
50/60 Hz

a
b
c
d
e
f
g

3.3d

9

Micrologic
Standard

j
k
l

Adjustable Instantaneous Trip Range k
Low
High
600
3000
700
3500
800
4000
900
4500
1000
5000
1200
6000
1400
7000
1600
8000
600
3000
700
3500
800
4000
900
4500
1000
5000
1200
6000
1400
7000
1600
8000

G Interrupting
Catalog Number l
$ Price
MGA26300( )
MGA26350( )
MGA26400( )
6633.
MGA26450( )
MGA26500( )
MGA26600( )
MGA26700( )
8370.
MGA26800( )
MGA36300
MGA36350
MGA36400
8168.
MGA36450
MGA36500
MGA36600
MGA36700
10608.
MGA36800

J Interrupting
Catalog Number l
MJA26300( )
MJA26350( )
MJA26400( )
MJA26450( )
MJA26500( )
MJA26600( )
MJA26700( )
MJA26800( )
MJA36300
MJA36350
MJA36400
MJA36450
MJA36500
MJA36600
MJA36700
MJA36800

Terminal
Wire Range

$ Price

8253.

3–3/0
through 500
kcmil
Al or Cu

10104.

9929.

3–3/0
through 500
kcmil
Al or Cu

12630.

The ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the long-time trip point setting. It is considered an electronic equivalent of a thermal-magnet circuit breaker.
UL magnetic trip setting tolerances are ±10% from the nominal values shown.
Fill in parentheses with the following phase connection options: (2) for AC and (5) for CA.

L-frame accessories . . . . . . . . . .starting on Supplemental Digest page 3-24
L-frame dimensions . . . . . . . . . . . . . . . . . . . . . . starting on Digest page 7-54
L-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-53

M-frame accessories. . . . . . . . . . . . . . . . . . . . . . starting on Digest page 7-36
M-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
M-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39

Table 9.135: Automatic Molded Case Switches—600 Vac, 50/60 Hz
Ampere
Rating
600 A
800 A
1000 A
1200 A
m
n

2-pole
Catalog Number n $ Price
PJA26000S60( )
6675.
PJA26000S80( )
7347.
PJA26000S10( )
8088.
PJA26000S12( )
10895.

3-pole
Catalog Number
PJA36000S60
PJA36000S80
PJA36000S10
PJA36000S12

$ Price
7263.
7938.
8676.
11766.

Withstand Rating m
240 Vac
480 Vac
600 Vac
100
65
25
100
65
25
100
65
25
100
65
25

Trip Point Amperes
AC
10000
10000
10000
10000

Terminal
Wire Range
3–3/0 through
500 kcmil Al or Cu
4–3/0 through
500 kcmil Al or Cu

The withstand rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a circuit breaker
with an equal ampere rating.
Fill in parentheses with the following phase connection options: (2) for AC or (5) for CA.

Table 9.136: PowerPact P- and R-frame Interrupt Ratings
Voltage
240 Vac
480 Vac
600 Vac

G
65 kA
35 kA
18 kA

P-frame Interrupt Rating
J
K
100 kA
65 kA
65 kA
50 kA
25 kA
50 kA

P- and R-frame accessories . . . . . . . . . . . . . . . starting on Digest page 7-36
P- and R-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55

© 2012 Schneider Electric
All Rights Reserved

DE2

Discount
Schedule

L
125 kA
100 kA
25 kA

G
65 kA
35 kA
18 kA

R-frame Interrupt Rating
J
K
100 kA
65 kA
65 kA
65 kA
25 kA
65 kA

PANELBOARDS

Type

D

L
125 kA
100 kA
50 kA

P- and R-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39

9-29

Circuit Breakers

PowerPact P- and R-frame for I-Line™ Panelboards and Switchboards
Class 612 / Refer to Catalog 0612CT0101
www.schneider-electric.us

9

Table 9.137: PowerPact P-frame 1200 A (600 Vac, 50/60 Hz) 3P Circuit Breaker with Electronic Trip Unit
Electronic Trip Unit
Type

Function

Code

PANELBOARDS

Basic Electronic Fixed long-time,
Trip Unit
Adjustable
ET1.0I
(Not
Interchangeable) Instantaneous

LI

3.0

Micrologic
Interchangeable
Standard
Trip Unit
LSI

LI

Micrologic
Interchangeable
Ammeter
Trip Unit

LSI

LSIG

LSI

5.0

3.0A

5.0A

6.0A

5.0P

Micrologic
Interchangeable
Power
Trip Unit
LSIG

LSI

6.0P

5.0H

Micrologic
Interchangeable
Harmonic
Trip Unit
LSIG

6.0H

Sensor
Rating

Cat. No.ab

600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A
250 A
400 A
600 A
800 A
1000 A
1200 A

P( )A36060
P( )A36080
P( )A36100
P( )A36120
P( )A36025(C)U31A
P( )A36040(C)U31A
P( )A36060(C)U31A
P( )A36080(C)U31A
P( )A36100U31A
P( )A36120U31A
P( )A36025(C)U33A
P( )A36040(C)U33A
P( )A36060(C)U33A
P( )A36080(C)U33A
P( )A36100U33A
P( )A36120U33A
P( )A36025(C)U41A
P( )A36040(C)U41A
P( )A36060(C)U41A
P( )A36080(C)U41A
P( )A36100U41A
P( )A36120U41A
P( )A36025(C)U43A
P( )A36040(C)U43A
P( )A36060(C)U43A
P( )A36080(C)U43A
P( )A36100U43A
P( )A36120U43A
P( )A36025(C)U44A
P( )A36040(C)U44A
P( )A36060(C)U44A
P( )A36080(C)U44A
P( )A36100U44A
P( )A36120U44A
P( )A36025(C)U63AE1
P( )A36040(C)U63AE1
P( )A36060(C)U63AE1
P( )A36080(C)U63AE1
P( )A36100U63AE1
P( )A36120U63AE1
P( )A36025(C)U64AE1
P( )A36040(C)U64AE1
P( )A36060(C)U64AE1
P( )A36080(C)U64AE1
P( )A36100U64AE1
P( )A36120U64AE1
P( )A36025(C)U73AE1
P( )A36040(C)U73AE1
P( )A36060(C)U73AE1
P( )A36080(C)U73AE1
P( )A36100U73AE1
P( )A36120U73AE1
P( )A36025(C)U74AE1
P( )A36040(C)U74AE1
P( )A36060(C)U74AE1
P( )A36080(C)U74AE1
P( )A36100U74AE1
P( )A36120U74AE1

G Interrupting a
80%
100%
Rated
Rated b

$ Price
J Interrupting a
K Interrupting a
80%
100%
80%
100%
Rated
Rated b
Rated
Rated b

L Interrupting ac
80%
100%
Rated
Rated b

Terminal
Wire Range
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

14603.

—

15480.

—

15480.

—

16359.

—

20003.

—

21207.

—

21207.

—

22410.

—

15390.

22479.

16268.

23897.

16268.

23897.

17147.

25314.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

20790.

—

21995.

—

21995.

—

23198.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

15729.

22794.

16608.

24231.

16608.

24231.

17487.

25668.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

21131.

—

22334.

—

22334.

—

23538.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

16242.

23270.

17121.

24737.

17121.

24737.

17999.

26204.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

21642.

—

22845.

—

22845.

—

24051.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

17739.

24659.

18618.

26214.

18618.

26214.

19497.

27770.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

23141.

—

24345.

—

24345.

—

25548.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

19607.

26393.

20486.

28058.

20486.

28058.

21365.

29721.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

25008.

—

26211.

—

26211.

—

27416.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

22151.

28754.

23030.

30566.

23030.

30566

23909.

32379.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

27552.

—

28757.

—

28757.

—

29960.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

23234.

29757.

24111.

31634.

24111.

31634.

24990.

33510.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

28634.

—

29838.

—

29838.

—

31041.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

26234.

32541.

27113.

34593.

27113.

34593.

27992.

36645

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

31634.

—

32837.

—

32837.

—

34043.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

27315.

33545.

28194.

35661.

28194.

35661.

29073.

37776.

(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K

32717.

—

33921.

—

33921.

—

35124.

—

(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K

Table 9.138: PowerPact R-frame 1200 A (600 Vac, 50/60 Hz) 3P Circuit Breaker with Electronic Trip Unit
Electronic Trip Unit
Type

Function

Code

Sensor
Rating

G Interruptingac
80%
100%
Rated
Rated

Cat. No.

$ Price
J Interruptingac K Interruptingac L Interruptingacd
80%
100%
80%
100%
80%
100%
Rated
Rated
Rated
Rated
Rated
Rated

Terminal
Wire
Range

Basic Electronic Trip Unit
(Not Interchangeable)

Fixed Long-Time,
R( )A36120
27080.
—
28777.
—
28777.
—
30533.
—
Adjustable Instantaneous ET1.01 1200 A
1000 A
R( )A36100CU31A
LI
3.0
—
33945.
—
36111.
—
36111.
—
38418.
Micrologic
1200 A
R( )A36120CU31A
Interchangeable Standard
1000 A
R( )A36100CU33A
Trip Unit
LSI
5.0
—
34401.
—
36599.
—
36599.
—
38934.
1200 A
R( )A36120CU33A
1000 A
R( )A36100CU41A
LI
3.0A
—
35141.
—
37383.
—
37383.
—
39770.
1200 A
R( )A36120CU41A
Micrologic
1000 A
R( )A36100CU43A
Interchangeable Ammeter
LSI
5.0A
—
36581.
—
38916.
—
38916.
—
41400.
AL1200R53K
1200 A
R( )A36120CU43A
Trip Unit
(4) 3/0-600 kcmil
1000 A
R( )A36100CU44A
Al or Cu
LSI
6.0A
—
38378.
—
40829.
—
40829.
—
43434.
1200 A
R( )A36120CU44A
1000 A R( )A36100CU63AE1
LSI
5.0P
—
40826.
—
43431.
—
43431.
—
46205.
Micrologic
1200 A R( )A36120CU63AE1
Interchangeable Power
1000 A R( )A36100CU64AE1
Trip Unit
LSIG
6.0P
—
41867.
—
44540.
—
44540.
—
47382.
1200 A R( )A36120CU64AE1
1000 A R( )A36100CU73AE1
LSI
5.0H
—
44754.
—
47610.
—
47610.
—
50649.
Micrologic
1200 A R( )A36120CU73AE1
Interchangeable Harmonic
1000 A R( )A36100CU74AE1
Trip Unit
LSIG
6.0H
—
45795.
—
48719.
—
48719.
—
51827.
1200 A R( )A36120CU74AE1
a
To complete the catalog number, replace the blank ( ) with the appropriate interrupt rating (G, J, K, or L).
b
For 100% rated circuit breakers add a “C” in the 9th character place. For example, the catalog number for a 100% standard-type trip unit with LI trip functions at 250 A would be PGA36025CU31A.
c
The L interrupt rating is supplied in 480 V only. Change the 5th character (voltage rating) from a 6 (600 V) to a 4 (480 V); for example, PLA34025U31A.
d
See Table 9.136 on Digest page 9-29 for interrupt ratings.
P- and R-frame accessories. . . . . . . . . . . . . . . . starting on Digest page 7-36
P- and R-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39
P- and R-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
P- and R-frame alternate rating plugs . . . . . . . . . . . . . . . . . Digest page 7-45
P- and R-frame trip unit options . . . . . . . . . . . . . . . . . . . . . Digest page 7-44

9-30

DE2

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

I-Line™ Factory
Assembled Panelboards

600 Vac, 250 Vdc
Class 2110 / Refer To Catalog 2110CT9701

www.schneider-electric.us

Panel Type

225 A
1356.
—
—
—
—

HCN
HCM
HCP-SU
HCP
HCR-U
a

Table 9.140: Standard Solid Neutral
Main Lugs
600 A
2276.
2276.
2990.
2456.
—

400 A
1866.
1866.
—
—
—

800 A
—
2512.
3600.
3056.
—

Ampere Rating
100/225 A
400 A
600 A
800 A
1200 A

1200 A
—
—
—
3968.
4602.

$ Price
294.
384.
544.
764.
1366.

PANELBOARDS

Table 9.139: Base $ Price—Main Lugs a

When required, add the $ Price of a solid neutral from Table 9.140.

Table 9.141: Base $ Price—Main Circuit Breaker b
Main Circuit Breaker

2
3
2
3

HCN
HCM

150 A
FI c HD c HG c
4642. 3360. 3860.
5864. 3770. 4210.
—
3360. 3860.
—
3770. 4210.

FA
2100.
2418.
—
—

FH
2100.
2958.
—
—

JD

JG

JJ

3956.
4440.
3956.
4440.
—
—

4146.
5550.
4146.
5550.
—
—

7126.
7466.
7126.
7466.
—
—

HJ c HL c
4540. 5550.
4890. 5900.
4540. 5550.
4890. 5900.

9

100 A

No.
Panel Type Poles

225 A
No.
Panel Type Poles
HCN
HCM
HCP, HCP-SU

2
3
2
3
2
3

400 A
LD

KI c

JL

LG

LJ

LL

600 A

LA

Electronic 100%
—
—
—
—
—
—
—
—

7356. 8356.
—
—
8676. 10148.
—
—
7356. 8356.
—
—
8676. 10148.
—
—
—
—
11865. 12470. 14795. 15940.
—
—

LH

LC c

LD

LI c

LG

LJ

LL

LC c

Electronic 80%
—
—
—
—
—
—
—
—

LI c

MG

6132. 9126.
—
—
—
—
—
—
—
7136. 10666
—
—
—
—
—
—
—
6132. 9126.
—
—
—
—
—
—
8880.
7136. 10666.
—
—
—
—
—
—
10770.
—
—
10366. 11610.
11176. 16504. 8880.
15425. 16215. 19235. 20725.
—
—
11888. 13354.
12678. 18090. 10770.

MJ
—
—
11260.
13400.
11260.
13400.

800 A d
No.
Panel Type Poles
HCN
HCM
HCP, HCP-SU

2
3
2
3
2
3

MG
—
—
11846.
14302.
11846.
14302.

PL b

MJ

PG c

PJ c

PL c PGC c PJC c PLC c

Micrologic™ 80%
Micrologic 100%
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14778.
—
—
—
—
—
—
—
17456.
—
—
—
—
—
—
—
14778. 19346. 15830. 16830. 21090. 16542. 18510. 24250.
17456. 23416. 18312. 20280. 24540. 20144. 22300. 28220.
1200 A cde

No.
Panel Type Poles
HCP, HCP-SU
HCR-U
b
c
d
e

2
3
2
3

PG

PJ

PL

22542.
24568.
22542.
24568.

24336.
26560.
24336.
26560.

26648.
29128.
26648.
29128.

PG

PJ

PL

Micrologic 80%
22380. 24980. 27980.
28710. 31310. 35570.
22380. 24980. 27980.
28710. 31310. 35570.

RGC

RJC

RLC

Micrologic 100%
24618. 24478. 32178.
31582. 34442. 40906.
24618. 24478. 32178.
31582. 34442. 40906.

When required, add the $ Price of a solid neutral from Table 9.140.
Standard construction back-fed main.
PG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. The “C” suffix denotes a 100% rating.
For 1200 A frame thermal magnetic circut breaker with 600 kcmil lugs, select an R-frame Thermal Magnetic circuit breaker in the Product Selector.

Table 9.142: Electronic Trip Units for H-frame Circuit Breakers
LI (3.0)
LSI (5.0)
LSIG (6.0) f

Standard $ Price
Standard
549.
—

Ammeter $ Price
—
2550.
4577.

Table 9.144: Electronic Trip Units (L-, P-, and R-frame Circuit Breakers)
Energy $ Price
—
3485.
5979.

Table 9.143: Electronic Trip Units for J-frame Circuit Breakers
LI (3.0)
LSI (5.0)
LSIG (6.0) f

Standard $ Price
Standard
785.
—

Ammeter $ Price
—
3643.
6538.

Energy $ Price
—
4978.
8542.

$ Price
LI (3.0)
LSI (5.0)
LSIG (6.0) f

Standard
Standard
1670.
—

Ammeter Energy Note:
—
—
4670.
7659.
9340.
13777.

Power
—
21600.
31000.

Harmonic
—
32330.
37000.

f

When adding G, requires current transformers and a box extension and is available
factory assembled only.
Note: Energy trip unit available for L-frame circuit breakers only.
PowerPact circuit breakers come with a standard LI trip unit. Use the above $ Price adder
for increase in trip functionality. See Digest page 7-43 for L- frame trip unit descriptions.
See Digest page 7-44 for P- and R- frame trip unit descriptions.

Table 9.145: I-Line 200% Rated Neutral—Standard Terminal Configuration g
Branch Space
Panel
Type

Ampacity

Type

Neutral Terminals Quantity and Size

In.

mm

Main

Branch

(35) 350 kcmil,
(9)#14-1/0, (17)#14-#4

HCM

600 A
600 A (MG, MJ)
800 A
800 A (MG, MJ)

MLO
M/B
MLO
M/B

72
72
72
72

1829
1829
1829
1829

(8) 750 kcmil
(8) 750 kcmil
(8) 750 kcmil
(8) 750 kcmil

HCR-Uh

1200A

M/B, MLO

108

2743

(8) 750 kcmil

600A

M/B, MLO

63

1600

(8) 750 kcmil

HCP

HCP-SUi
g
h
i

800A

M/B, MLO

99

2515

(8) 750 kcmil

800A

M/B, MLO

54

1371

(8) 750 kcmil

(8) 600 kcmil, (15) 350 kcmil
(9) #14-1/0, (17)#14-#4
(35) 350 kcmil,
(9)#14-1/0, (17)#14-#4
(35) 350 kcmil,
(9)#14-1/0, (17)#14-#4
(8) 750 kcmil, (21) 350 kcmil,
(9) #14-1/0, (17) #14-#4

Type 1 Enclosure
H
In.
91
91
91
91

W
mm
2311
2311
2311
2311

In.
32
32
32
32

D
mm
813
813
813
813

In.
8.25
9.50
8.25
9.50

mm
210
241
210
241

86

2184

44

1118

9.50

241

68

1727

42

1067

9.50

241

86

2184

42

1067

9.50

241

86

2184

26

660

9.5

241

Available in Type 1 enclosure only; for pricing, see Digest page 9-34.
6 in. enclosure extension is required for HCRU I-Line panelboard.
9 in. enclosure extension is required for HCP-SU I-Line panelboard.

© 2012 Schneider Electric
All Rights Reserved

PE1

Discount
Schedule

9-31

I-Line™ Factory
Assembled Panelboards

600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701
www.schneider-electric.us

9

Table 9.146: Branch Circuit Breakers—Thermal Magnetic Circuit Breakers a
(See Digest pages 7-4 through 7-8 for interrupt rating, voltage ratings, Fed. Specs, etc.)

PANELBOARDS

Circuit Breaker
Ampere Rating

Circuit
Breaker

15–60 A
70–100 A
15–60 A
70–100 A
15–60 A
70–100 A
20–100 A
15–60 A
70–100 A
110–150 A
15–60 A
70–100 A
110–150 A
15–60 A
70–100 A
110–150 A
15–60 A
70–100 A
110–150 A
70–225 A
70–225 A
70–225 A
70–225 A
150–225 A
250 A
150–225 A
250 A
150–225 A
250 A
150–225 A
250 A
150–225 A
250 A
300–400 A
300–400 A
300–400 A
450–600 A
300–400 A
450–600 A
300–600 A
700–800 A
300–600 A
700–800 A
600–800 A
600–1200 A
600–1200 A
1000–1200 A
250–400 A
450–600 A
700–800 A

FA (FY-1P)
FA

1000–1200 A
a
b
c
d
e

9-32

FH
FJd
FI
HD

HG

HJ

HL
QB
QD
QG
QJ
JD
JG
JJ
JL
KI
LA
LH
LC
LI
MG
MJ
PL
PG
PJ /PK
PL
PLC (100%) e
RG (80%) e
RJ (80%) e
RL (80%) e

3-pole e
240 V
720.
832.
1100.
1300.
1300.
1500.
—
—
—
—
—
—
—
—
—
—
—
—
—
1696.
2208.
2870.
3070.
—
—
—
—
—
—
—
—
—
—
—
—
5460.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

480 Vac
250 Vdc
882.
1142. b
—
—
2080.
2470.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20360.
—
—
24526.
16940.
22620.
24440.
—
—
—

600 V
1006.
1218.
1442.
1940.
—
—
4254.
1350.
1570.
2710.
1710.
2198.
3310.
2380.
2700.
4500.
3910.
4054.
5530.
—
—
—
—
2820.
3800.
3990.
4180.
6110.
6500.
7320.
8900.
7972.
9268.
4916.
5312.
10156.
10422.
11622.
15834.
8152.
10600.
10126.
13306.
—
19966.
21960.
—
—
—
—
24460.
26710.
32580.

2-pole e
Space
Only
98.
98.

H
(In.)
4.5
4.5

98.

4.5

98.

3

98.

4.5

98.

4.5

98.

4.5

98.

4.5

98.

4.5

98.
98.
98.
98.

4.5
4.5
4.5
4.5

98.

4.5

98.

4.5

98.

4.5

98.

4.5

98.
252.

6
7.5

456.

7.5

662.

9

662.

9

662.
662.
662.
662.

9
9
9
9

662.

9

662.

15

520.
632.
1050.
1250.
1250.
1450.
—
—
—
—
—
—
—
—
—
—
—
—
—
560.
1300. b
2800.
3000.
—
3600.
4600.
3900.
4000.
4300.
4300.
—
—
—
—
4550.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

4.5

456.

240 Vac

480 Vac
250 Vdc
708.
956.
—
—
1660.
1980.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5434.
6672.
5434.
6672.
—
—
—
—
—
—
—
—
—
—
—
—
16290.
—
—
22046.
13550.
18100.
19560.
—
—
—

1-pole e

600 Vac
786.
964.
1218.
1620.
—
—
3466.
1150.
1370.
2370.
1352.
1508.
3110.
2002.
2364.
3980.
3250.
3402.
4600.
—
—
—
—
2600.
3430.
2790.
3620.
5770.
6450.
6000.
6800.
6216.
7262.
3980.
4500.
8634.
8920.
9878.
14248.
6322.
8180.
8536.
10944.
—
17940.
19724.
—
—
—
—
24460.
26710.
32580.

b

b
b

b
b

Space
Only

H
(In.)

82.

3

98.

3

98.

3

98.

4.5

98.

3

98.

3

98.

4.5

98.

4.5

82.
82.
82.
82.

3
3
3
3

98.

4.5

98.

4.5

98.

4.5

98.

4.5

98.

4.5

252.

6

456.

7.5

456.

7.5

662.

9

662.

9

662.

9

662.

9

662.

9

662.

9

662.

15

120 V
—
354.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

277 V
—
384.
—
—
664.
832.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

277 Vac
125 Vdc
270. c
384. c
518.
650.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

Space
Only
72.
72.
72.
72.
72.
72.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

H
(In.)
1.5
1.5
1.5
1.5
1.5
1.5
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

See Digest pages 7-4 through 7-8 for additional dc ratings.
ac only.
FA, 1P.
480Y/277 Volt rated circuit breaker—Do not use on 480 Volt 3Ø3W Delta systems.
See Table 9.144 on Digest page 9-31 for P- and R frame Micrologic trip unit price adders.

PE1

Discount
Schedule

© 2012 Schneider Electric
All Rights Reserved

I-Line™ Factory
Assembled Panelboards

600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701

www.schneider-electric.us

Table 9.147: Branch Circuit Breakers—Electronic Trip Circuit Breakers a
(See Digest pages 7-4 through 7-8 for interrupt rating, voltage ratings, Fed. Specs, etc.)

1000–1200 A
a
b
c
d
e

HD (80%) b
JD (80%) c
HG (80%) b
JG (80%) c
HJ (80%) b
JJ (80%) c
HL (80%) b
JL (80%) c
LD (80%) d

LG (80%) d

LJ (80%) d

LL (80%) d
LDC (100%) d
LLC (100%) d
LGC (100%) d
LJC (100%) d
DG (100%) e
DG (80%) e
DJ (100%) e
DJ (80%) e
DL (100%) e
DL (80%) e
PG (80%) d

PJ/PK (80%) d

PL (80%) d

PGC (100%) d
PJC/PKC (100%)
d
PLC (100%) d
RG (100%) d
RJ (100%) d
RL (100%) d

2-pole d

3-poled
240 V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

480 Vac
250 Vdc
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5687.
8954.
9118.
12385.
10573.
13839.
—
—
—
—
—
—
—
—
15400.
20570.
22220.
29850.
—
—
—
—
—
—
16940.
22620.
24440.
—
—
—

600 V
1790.
2102.
3756.
4013.
2110.
2380.
4848.
5082.
2703.
2898.
6895.
7231.
4027.
4263.
8943.
9381.
5378.
5378.
7775.
5645.
5645.
8167.
9212.
9212.
11378.
10724.
10724.
12738.
6991.
6991.
13941.
13941.
7338.
7338.
11975.
11975.
—
—
—
—
—
—
8900.
13310.
14730.
21240.
10400.
15570.
17220.
24850.
—
—
—
—
9790.
14642.
16200.
11960.
17900.
19800.
—
—
—
29317.
32159.
39389.

Space
Only
98.
98.
98.
98.
98.
98.
98.
98.
98.
98.
98.
98.
98.
98.
98.
98.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.
252.

H

240 Vac

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

662.

9

662.

9

662.

9

662.

9

662.

9

662.

9

662.

15

480 Vac
250 Vdc
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
4550.
7163.
7295.
9908.
8458.
11071.
—
—
—
—
—
—
—
—
12320.
16450.
17780.
23880.
—
—
—
—
—
—
13550.
18100.
19560.
—
—
—

600 Vac
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
7120.
10648.
12402.
16992.
9240.
12450.
13780.
19880.
—
—
—
—
7832.
11714.
13642.
9570.
14330.
15840.
—
—
—
29317.
32159.
39389.

1-pole d
Space
Only
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
252.
252.
252.
252.
252.
252.

H

120 V

277 V

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
6
6
6
6
6
6

662.

9

662.

9

662.

9

662.

9

662.

9

662.

9

662.

15

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

277 Vac
125 Vdc
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

Space
Only
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

H
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

See Digest pages 7-4 through 7-8 for additional dc ratings.
See Table 9.142 on Digest page 9-31 for H-frame electronic trip unit price adders.
See Table 9.143 on Digest page 9-31 for J-frame electronic trip unit price adders.
See Table 9.144 on Digest page 9-31 for L-, P-, and R-frame electronic trip unit price adders.
See the Supplemental Digest for D-frame electronic trip unit price adders.

© 2012 Schneider Electric
All Rights Reserved

PE1

Discount
Schedule

9-33

PANELBOARDS

15–60 A
35–100 A
50–150 A
70–250 A
15–60 A
35–100 A
50–150 A
70–250 A
15–60 A
35–100 A
50–150 A
70–250 A
15–60 A
35–100 A
50–150 A
70–250 A
70–250 A
125–400 A
200–600 A
70–250 A
125–400 A
200–600 A
70–250 A
125–400 A
200–600 A
70–250 A
125–400 A
200–600 A
70–250 A
125–400 A
70–250 A
125–400 A
70–250 A
125–400 A
70–250 A
125–400 A
60–400 A
600 A
60–400 A
600 A
60–400 A
600 A
250–400 A
450–600 A
700–800 A
1000–1200 A
250–400 A
450–600 A
700–800 A
1000–1200 A
250–400 A
450–600 A
700–800 A
1000–1200 A
250–400 A
450–600 A
700–800 A
250–400 A
450–600 A
700–800 A
250–400 A
450–600 A
700–800 A

Circuit
Breaker

9

Circuit Breaker
Ampere Rating

I-Line™ Factory Assembled Panelboards

Common Feature Pricing
Class 2110 / Refer to Catalog 2110CT9701
www.schneider-electric.us

9

Table 9.148: QO Plug-On Branch Circuit Breakers

Table 9.156: Door-in-Door Trim
$ Price

Transition Charge per 6 QO one-pole spaces
(H=4.5 in. per 6 one-pole spaces)
QO Branch circuit breakers

328.
See Digest page 7-10

Door-in-Door Trim
Trim has piano hinge down one side.
Door opens by single latch; Entire trim opens by removing screws.
Hinged Door-in-Door with Outer Door Lock Added

$ Price Adder
646.
836.

Table 9.157: Weatherproof or Dusttight Cabinets—Type 3R, 5, 12
PANELBOARDS

Table 9.149: Sub-feed/Feed-through Lugs a
Ampere Rating
225 A
400 A
600 A
800 A
1200 A
a

$ Price
368.
600.
858.
1490.
1890.

Weatherproof or Dusttight Cabinets
Maximum 26 in. wide box
Maximum 28 in. wide box
Maximum 32 in. wide box
Maximum 42 in. wide box
Maximum 44 in. wide box

Table 9.158: Copper Mechanical Lugs

2 or 3-pole Branch Mounted; SL Kit used for both SFL and TFL.

Main Lug Interiors

Ampere Rating
$ Price
Equipment Ground Bar
Copper Ground Bar b

180.
148.
$ Price Additional
Neutral Assembly

b

Main Circuit Breaker Interiors
$ Price per Pole
70.
108.
148.
168.
196.
236.

Table 9.150: Ground Bars

Insulated/Isolated Ground Bar

$ Price Adder
2156.
3312.
3312.
3312.
3312.

100/125 A
250 A
400 A
600 A
800 A
1200 A

70.
108.
148.
168.
196.
236.

Add to equipment ground bar $ Price.

Table 9.159: Copper Compression Lugs
Table 9.151: Name Plates
$ Price
Standard white face/black letter laminated bakelite, 1 in. x 3.5 in., adhesive backed
or screw mountable with screws in a bag assembly ($ Price includes engraving)

78.

Table 9.152: Copper Bus Bars
Ampere Rating
225 A
400 A
600 A
600 A
800-1200 A

Type
HCN, HCM
HCN, HCM, HCP
HCN
HCM, HCP, HCR-U
HCP, HCR-U

$ Price
528.
720.
720.
1274.
1274.

Type
Copper Neutral
Copper Neutral
Copper Neutral
Copper Neutral

70.
108.
148.
168.
316.
—

Table 9.160: Aluminum Compression Lugs VCEL
Main Circuit Breaker Interiors c

Main Lug Interiors

Ampere Rating

$ Price Per Pole
29.00
N/A
29.00
45.00
59.00
100.00
118.00

100 A
150 A
250 A
400 A
600 A
800 A
1200 A

$ Price Adder
868.
894.
1108.
1352.

29.00
29.00
49.00
74.00
131.00
—
—

Note: Additional factory modifications. See Digest page 9-38.
c
Compression lugs are not available on LC, LI, LE, LX, and LXI circuit breakers.

Table 9.154: 200% Rated Neutrals
Ampere Rating
225 A
400 A
600 A
800 A
1200 A
225 A
400 A
600 A
800 A
1200 A

Main Circuit Breaker Interiors
$ Price per Pole
70.
108.
148.
168.
316.
836.

100/125 A
250 A
400 A
600 A
800 A
1200 A

Table 9.153: Neutrals
Ampere Rating
100–400 A
600 A
800 A
1200 A

Main Lug Interiors

Ampere Rating

Type
Aluminum
Aluminum
Aluminum
Aluminum
Aluminum
Copper
Copper
Copper
Copper
Copper

$ Price Adder
820.
940.
1340.
1350.
2020.
1210.
1300.
1980.
2500.
2900.

Surgelogic™ SPD
Surgelogic SPD unit in I-Line plug-on
construction: An integrally mounted surge
protection solution that mounts on to an
I-Line Panelboard bus stack just like a
J-Frame circuit breaker. Requires 13.5 in.
of mounting height. Available as factory
assembled and merchandised. For SPD
unit pricing and information, see Digest
pages 6-3 and 6-44.
I-Line Plug-On Unit with
Surgelogic SPD

Table 9.155: Metal Directory Frame
Metal Directory Frame
Frame attached to trim (not available on four piece trim)

$ Price Adder
140.

Table 9.161: Surgelogic SPD Options
Surgelogic SPD Options

$ Price
Standard

Dry Contacts
Remote Monitor

2588.

Note: Requires HCM interior minimum.

Table 9.162: Surgelogic Branch Mounted I-Line SPD—Model IMA
Surge Current Rating kA
Voltage
120/240 1P3W
208Y/120 3P4W
240/120 3P4W
480Y/277 3P4W
600Y/347 3P4W

9-34

100 kA
HL
18908.
19750.
19750.
20602.
—

120 kA
FI
20416.
21260.
21260.
22110.
23000.

HL
20088.
20984.
20984.
21898.
—

160 kA
FI
21692.
22588.
22588.
23492.
24438.

PE1

HL
23634.
24688.
24688.
25752.
—
Discount
Schedule

200 kA
FI
25520.
26574.
26574.
27638.
28750.

HL
29354.
30740.
30740.
32130.
—

240 kA
FI
30958.
32342
32342.
33734.
35198.

HL
34534.
36164.
36164.
37800.
—

FI
36420.
38050.
38050.
39686.
41400.

© 2012 Schneider Electric
All Rights Reserved

QMB Fusible Branch
Switches

For QMB/QMJ Panelboards and Switchboards
Class 4620 / Refer to Catalog 4620CT9601

www.schneider-electric.us

Table 9.163: QMB Branch Switch Units

2-pole, 240 Vac
30 A-30 A
4.5
30 A-Blank
4.5
60 A-60 A
4.5
60 A-Blank
4.5
100 A-100 A
6
100 A-Blank
6
200 A
9
15
400 A
9
600 A

Catalog
Number

$ Price

No.
Kits
Req’d.

QMB221TW
608.
2
QMB221HWb
425.
1
QMB222TW
608.
1
QMB222HWb
425.
QMB223TW
990.
1
QMB223HWb
695.
QMB224W
1200.
1
QMB225W
3072.
1
QMB225WT3c 2981. —
Use 3-pole devices
for 2-pole application.

3-pole, 240 Vac
30 A-30 A
4.5
QMB321TW
827.
2
30 A-Blank
4.5
QMB321HWb
587.
1
60 A-60 A
4.5
QMB322TW
827.
1
60 A-Blank
4.5
QMB322HWb
587.
100 A-100 A
6
QMB323TW
1265.
1
100 A-Blank
6
QMB323HWb
879.
200 A
9
QMB324W
1673.
1
15
QMB325W
4277.
1
400 A
9
QMB325WT3 c 4143. —
15
QMB326W
6249.
1
600 A
15
QMB326WT3 c 6249. —
800 A
15
QMB327WT3c 12140. —
2-pole, 600 Vac, 250 Vdcd
30 A-30 A
4.5
QMB261TW
1050.
1
30 A-Blank
4.5
QMB261HWb
702.
60 A-60 A
6
QMB262TW
1050.
1
60 A-Blank
6
QMB262HWb
738.
100 A-100 A
7.5
QMB263TW
1536.
2
100 A-Blank
7.5
QMB263HWb
1083.
1
200 A
9
QMB264W
1791.
1
400 A
Use 3-pole devices
for 2-pole application.
600 Ae
3-pole, 600 Vacd
4.5
30 A-30 A
4.5
30 A-Blank
4.5
6
60 A-60 A
6
60 A-Blank
6
6
60 A-30 A
6
7.5
100 A-100 A
6
7.5
100 A-Blank
6
7.5
100 A-30 A
7.5
7.5
100 A-60 A
7.5
200 A
9
200 A-200 A
7.5
200 A-Blank
7.5
400 Af
15
400 A
9
400 Af
9
600 Aef
15
60 A0
15
800 Ag
15
a
b
c
d
e
f
g
h
i

QMB361TW
QMJ361T
QMB361HWb
QMB362TW
QMJ362T
QMB362HWb

1241.
1293.
861.
1241.
1293.
861.

QMB362T21W

1241.

QMB363TW
QMJ363T
QMB363HWb
QMJ363Hb

1961.
2013.
1373.
1424.

QMB363T31W

1961.

QMB363T32W

1961.

QMB364W
2306.
QMJ364T
4712.
QMJ364Hb
2357.
QMB365W
5445.
QMJ365
5561.
QMB365WT6h 5276.
QMB366W
6735.
QMJ366
6704.
QMB367W
12140.

1
—
1
1
—
1

Electrical Interlock Kit

Horsepower Ratingsi
240 Vac

Catalog
Number

$ Price

Catalog
Number a

$ Price

Std.

480 Vac
Max.

1Ø

3Ø

1Ø

3Ø

Std.

600 Vac
Max.

Std.

1Ø

3Ø

1Ø

3Ø

1Ø

3Ø

—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—

5
5
10
10
20
20
40
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

QMB100R

95.00 QMB610EK(1 or 2)

357.

7.5

15

15

30

HRK1020
QMB4060R
—

47.70 QMB200EK(1 or 2)
111.00
—
—
—

357.
—
—
—
—

—
—
—
—
—

25
—
—
—
—

15
—
—
—
—

60
—
—
—
—

3
3
7.5
7.5
15
15
25
50
50
75
75
75

—
—
—
—
—
—
—
—
—
—
—
—

7.5
7.5
15
15
30
30
60
125
—
150
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

3

5

7.5

15

3

5

15

20

30

10

25.50 QMB300EK(1 or 2)

357.

1.5

3

3

7.5

QMB36R

48.90 QMB300EK(1 or 2)

357.

3

7.5

10

15

—

QMB100R

95.00 QMB610EK(1 or 2)

357.

HRK1020
QMB4060R
—
QMB4060R
—
—

47.70 QMB200EK(1 or 2)
111.00
—
—
—
111.00
—
—
—
—
—

357.
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

QMB36R

48.90 QMB300EK(1 or 2)

357.

1.5

QMB60R

48.90

357.

3

HRK30
QMB36R

25.50

357.
QMB300EK(1 or 2)

48.90

357.

HRK1020

47.70

357.

7.5

HRK1020

47.70 QMB200EK(1 or 2)

357.

15

—
—
—
—
—
—
—

—

—

—

—

—

—

—

—

—

—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

3
—
3
7.5
—
7.5
—
—
15
—
15
—
—
—
—
—
25
25
—
—
50
—
—
75
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

7.5
—
7.5
15
—
15
—
—
30
—
30
—
—
—
—
—
60
60
—
—
125
—
—
150
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

5
—
5
15
—
15
—
—
25
—
25
—
—
—
—
—
50
50
—
100
100
—
150
—
150

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

15
—
15
30
—
30
—
—
60
—
60
—
—
—
—
—
125
125
—
250
250
—
400
—
400

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

QMB36R
—
QMB36R
QMB60R
—
QMB60R
and
1 ea. QMB60R
QMB36R
2
HRK1020
—
—
1
HRK1020
—
—
and
1 ea. HRK1020
QMB36R

QMB610EK(1 or 2)

48.90
—
48.90
48.90
—
48.90
48.90
—
47.70
—
47.70
—
47.70
48.90
and 47.70
1 ea. HRK1020
QMB60R
48.90
1
HRK1020
47.70
—
—
—
—
—
—
1
QMB4060R 111.00
—
—
—
—
—
—
1
QMB4060R 111.00
—
—
—
—
—
—

—

QMB300EK(1 or 2)

357.

QMB300EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

QMB200EK(1 or 2)

357.

QMB610EK(1 or 2)

357.

—
QMB200EK(1 or 2)
—
—
—
—

—
357.
—
—
—

10

25

30

60

15

—

—
—
—
—
—
—
—

25

50

50

125

30

—
—
—
—
—
—
—

3
10
15

250 Vdc

3Ø

—
—
—
—
—
—
—
—
—
—
—

HRK30

Max.

1Ø

50

—
—
—
—
—
—
—

—

—

—

—

7.5
—
7.5
15
—
15
—
—
30
—
30
—
—
—
—
—
60
60
—
125
125
—
250

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

20
20
20
50
—
50
—
—
75
—
75
—
—
—
—
—
150
150
—
350
350
—
500
—
500

—
5
—
—
10
—
—
—
—
20
—
20
—
—
—
—
—
40
—
50
50
—
—
—
—

250

10
25
40

5
10
20
40

“1’’ indicates one normally open and one normally closed contact.
“2’’ indicates two normally open and two normally closed contacts.
Blank units cannot be modified to accept a switch interior.
Use 300 Vac Class T fuses only.
Class J fuse provisions—to field modify switch, move load side fuse base to position indicated in switch. Not available on 100-30, 100-60, or 800 A switch units.
To adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB600T6, $ Price 194. (Use T6 fuses with standard horsepower ratings only).
250 Vdc rating.
To adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB800T6, $ Price 467. (Use T6 fuses with standard horsepower ratings only).
Use 600 Vac Class T fuses only.
Horsepower rating applicable to 480Y/277 V system only.

Note: See the Supplemental Digest for merchandised motor starter units, QMB RTI panelboards, and replacement switches for Series 1–4 and D2 QMB panelboards.
Note: For series E1 and E2, QMJ switches may be used in 400 A–1200 A interiors in a NEMA 1 without door only. QMJ switches cannot be used in series E1 and E2, 225 A panelboards. QMJ
switches cannot be used in NEMA 1 with door or any NEMA 3R/12 enclosure.

© 2012 Schneider Electric
All Rights Reserved

PE1A

Discount
Schedule

9-35

PANELBOARDS

Unit
Height
(In.)

9

Class R Fuse Kits
Unit
Ampere
Rating

QMB Factory Assembled Panelboards

Fusible—600 Vac, 250 Vdc
Class 4620 / Refer to Catalog 4620CT9601
www.schneider-electric.us

9

Table 9.164: Base $ Price
Main Switch a

Main Lugs
Maximum
Mounting
Space
(In.)
—
—
60
60
60
60
45

Mains
Rating
(Amperes)

PANELBOARDS

—
—
225
400
600
800
1200
a
b
c
d
e

Base
$ Price
(2- or 3-pole)

Mains
Rating
(Amperes)

—
—

100
200
—
400
600
800b
—

1098.
1344.
2066.
2550.
3550.

240 Vac

Maximum
Mounting
Space
(In.)
51
51
—
45
45
45
—

Base $ Price
2-pole
2544.
2544.
—
4840.
7298.c
11098.
—

Solid Neutral
(Main Lugs and Main Switch)

600 Vac
Base $ Price

3-pole
3104.
3104.
—
6158.
8758.c
13704.c
—

2-pole
3026.
3026.
—
5906.
7968.de
11128.d
—

Ampere
Rating

3-pole
3632.
3632.
—
7300.
9338.d
13724.d
—

$ Price

100 A
200 A
225 A
400 A
600 A
800 A
1200 A

294.
294.
294.
384.
556.
786.
912.

Pricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches.
800 A switch unit with provision for UL Class L fuses.
Switches for use with 300 V Class T fuses are also available at no additional cost.
For 600 Vac UL Class T fuse provision on main switch, add $ 321.00
250 Vdc rating.

Table 9.165: Branch Switch $ Price f
Unit Ampere
Rating

Switch
Type

Twin Mounted Branch Switches g
30 A-Blank
QMB
60 A-Blank
QMB
QMB
100 A-Blank
QMJ hm
200 A-Blank
QMJ hm
60 A-30 A
QMB
100 A-30 A
QMB
100 A-60 A
QMB
QMB
30 A-30 A
QMJ hm
QMB
60 A-60 A
QMJ hm
QMB
100 A-100 A
QMJ hm
200 A-200 A
Single Mounted Branch Switches
200 A
QMB
400 A
QMB
400 Ai
QMB
400 A
QMJ hm
600 A
QMB
600 A
QMJ hm
800 Al
QMB
f
g
h
i
j
k
l
m

240 Vac
2-pole
$ Price

3-pole
$ Price

592.

600 Vac

Space Only
$ Price

784.

898.

1104.

—
—
—

—
—
—

Unit Mounting Height
(In.)

2-pole
$ Price

3-pole
$ Price

Space Only
$ Price

2576.
1446.

294.
396.
462.
396.
462.
396.

4.5
6
7.5
6
7.5
6

2274.

462.

7.5

1446.

294.

4.5

1446.

396.

6

462.
396.
462.

7.5
6
7.5

580.
878.

9
15

580.

9

878.

15

294.

4.5

852.

392.

6
—
—
—

1276.

1592.

1984.
1216.
1822.

—
—
—

1012.

1822.

2274.

396.

6

826.

1120.

294.

4.5
—
4.5
—
6
—
—

1216.h
1216.
1216.h
1216.
1822.j
1822.
3970.

5154.

9
15
9
—
15
—
15

1984.h
4300.h
4098.hi
4098.
5264.hk
5264.
10682.k

2576.
5764.h
5552.hi
5552.
6962.hk
6962.
10682.k

—

—
826.

—
1120.

—

—
1282.

294.
—

1576.

—
—

—
—

1484.
3204.
3040.i
—
4888.j
—
10682.

2034.
4562.
4360.i
—
6374.hj
—
10682.j

396.
—
—
580.
878.
580.
—
878.
—
878.

Unit Mounting Height
(In.)

2274.

Pricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches.
$ Price is per twin switch.
250 Vdc rating.
For use with Class T fuses only. Use 300 V Class T fuses on 240 Vac max. systems and 600 V Class T fuses on 600 Vac max. systems.
Switches for use with 300 V Class T fuses are also available at no additional cost.
For 600 Vac UL Class T fuse provision on branch switch, add $ 307.00
800 A switch unit with provision for UL Class L fuses.
QMJ switches are available in NEMA 1 enclosures only.

Table 9.166: Accessories
Electrical Interlocks
Number of Contacts
Normally Open

1
2

n
o

Branch Switches
30–200 A $ Price

Normally Closed

1
2

472.

Mains Ampere
Rating

Sub-feed Lugs n
for Main Lugs Interior n

Feed-through Lugs for Main
Switch Interior

200 A
225 A
400 A
600 A
800 A
1200 A

—

—
—

282.
466.
856.
1150.
1440.

Copper
Bus Bars
488.
488.
720.
1148.
1372.
1428.

872.o
1268.o
1512.o
—

No extra box height required.
Box height increases 6 in. Not available in Type 3R/5/12 construction.

Table 9.167: Circuit Breakers, Twin Mounted H-frame— $ Price Per Twin Unit
Circuit Breaker Ampere Rating

$ Price—3-pole

Left Unit

Right Unit

Unit Mounting Height
(In.)

15–150 A

15–150 A

6

240 V
HD
2914.

480 V
HG
3572.

HD
3324.

600 V
HG
3814.

HD
3674.

HG
4018.

Space Only
396.

Note: See the Supplemental and Obsolescence Digest for merchandised motor starter units, QMB RTI panelboards, and replacement switches for Series 1-4 and D2 QMB panelboards.

Table 9.168: Circuit Breaker, Single Mounted JD-LA— $ Price Each
$ Price—3-pole
Circuit Breaker
Ampere Rating

Unit Mounting Height
(In.)

150–250 A
225–400 A

6
7.5

600 V
JD

JG
3800.

—

5814.
—

Space Only

LA
—

396.
462.

5664.

Table 9.169: UL Listed Short Circuit Ratings
Starter Size
0
1
2
3

9-36

Fusible Switch—600 V Max. (w/Class R or J Fuses) RMS Sym. Amps
100,000
100,000
100,000
100,000

PE1

Discount
Schedule

Thermal-magnetic Circuit Breaker 600 V Max. RMS Sym. Amps
5,000
5,000
5,000
5,000
© 2012 Schneider Electric
All Rights Reserved

QMB Factory Assembled
Panelboards

Common Features
Class 4620 / Refer to Catalog 4620CT9601

www.schneider-electric.us

Table 9.175: Aluminum Compression Lugs VCEL—
Main or Branch Switches

Item
$ Price
Equipment Ground Bar
180.
Copper Ground Bar
148. a
Insulated/Isolated Ground Bar
ab
Name Plates
78. c
a
Add to Equipment Ground Bar $ Price.
b
$ Price an additional Neutral Assembly from Table 9.164 on Digest page
9-36 for Al insulated ground bar or from Table 9.171 for Cu insulated
ground bar.
c
Standard white face/black letter laminated bakelite, 1 in. x 3.5 in.
adhesive backed or screw mountable with screws in a bag assembly.
($ Price includes engraving.)

Aluminum Compression Lugs VCEL
100 A #8–1/0 Al or Cu
200 A #4–300 kcmil Al or Cu
400 A 2/0–500 kcmil Al or Cu
600 A 2/0–500 kcmil Al or Cu
800 A 2/0–500 kcmil Al or Cu or 500 kcmil Cu or
500–750kcmil Al.

Copper Compression Lugs
200 A
400 A
600 A
800 A

Table 9.172: Copper Mechanical Lugs—Main Switch Interiors
Copper Mechanical Lugs
200 A
400 A
600 A
800 A

$ Price
108.
148.
168.
196.

Table 9.173: Copper Compression Lugs—Main Lug Interiors
$ Price
108.
148.
168.
316.
836.

Voltage
Surge
Current 120/240 V 208Y/120 V 240/120 Vac 480Y/277 Vac 600Y/347 Vac
Rating
3Ø4W
kA
1Ø3W
3Ø4W
3Ø4W
3Ø4W
High Leg
100
—
14310.
—
15410.
—
120
—
15654.
—
16754.
—
160
—
18586.
—
19686.
—
200
19196.
23596.
23596.
26896.
26896.
240
23760.
27440.
27440.
31460.
31460.
d
Requires 9 in. of mounting height.

Table 9.178: SPD Options
Surge Counter
Dry Contacts
Remote Monitor

$ Price
Standard
Standard
2588.

QMB Layout Information

Table 9.174: Aluminum Compression Lugs VCEL—
Main Lug Interiors
Aluminum Compression Lugs VCEL
225 A
400 A
600 A
800 A
1200 A

$ Price
108.
148.
168.
196.

Table 9.177: Surgelogic™ SPD for QMB d

Surgelogic SPD Options
Copper Compression Lugs
225 A
400 A
600 A
800 A
1200 A

262.

9

$ Price
868.
894.
1108.
1352.
N/A
3054.
Standard

58.
98.
128.
246.

Table 9.176: Copper Compression Lugs—Main Switch Interiors

Table 9.171: Copper Neutral

Copper Neutral
125–400 A
600 A
800 A
1200 A
Hinged Trim
Weatherproof or Dusttight Cabinets—Type 3R, 5, 12; 800 A Max.
Mechanical Lugs 225 A–1200 A

$ Price

$ Price
58.
90.
118.
200.
236.

Main Switch or
Main Lugs

100 A twin QMB
6" H @ 240 Volt

Maximum
Mounting
Space
for
Branch
Units

60 A twin QMB
6" H @ 600 Volt

30/30 @ 240 or 600 V
or 60/60 @ 240 V
are 4.5" high
Wiring Gutter

100 A twin QMB
7.5" H @ 600 Volt
100 A twin QMJ
6" H @ 600 Volt
200 A QMB
9" mounting height,
200 Amp twin QMJ
7.5" mounting height
400 A QMJ 9" H,
400 A Class T 9" H,
400, 600 or 800 A
QMB all require 15" H
38"

To maximize the quantity of branch switches, use QMJ
switches from Digest page 9-36. Class J fuses are available in
time delay construction suitable for motor and transformer
loads.

© 2012 Schneider Electric
All Rights Reserved

PE1

Discount
Schedule

PANELBOARDS

Table 9.170: Ground Bar and Name Plates

9-37

Modifications for Factory Assembled Panelboards
Class 1640, 1670, 2110, 4620, 6650 / Refer to Catalog 2110CT9701, 1640CT0801, 4620CT9601
www.schneider-electric.us

9

Table 9.179: NQ and NF Lighting Contactors—Mechanically Held

Table 9.181: NQ and NF Panelboard Split Bus Bars

(Furnish a one-line power and control voltage connection diagram.)

Maximum
Ampacity
MLO

Mechanically Held
Ampacity

Type

Minimum Additional
Box Height Required a
H (In.)

$ Price

PANELBOARDS

Square D™ Brand PB b
30 A 2P
PBM10B

3772.

18

60 A 2P

PBP10B

4634.

18

75 A 2P

PBN10B

4986.

18

100 A 2P

PBQ10B

5072.

18

150 A 2P

PBR10B

7156.

18

200 A 2P

PBV10B

8692.

18

225 A 2P

PBW10B

9830.

18

30 A 3P

PBM11B

3740.

18

60 A 3P

PBP11B

4754.

18

75 A 3P

PBN11B

5628.

18

100 A 3P

PBQ11B

6454.

18

150 A 3P

PBR11B

8078.

18

200 A 3P

PBV11B

8736.

18

225 A 3P

PBW11B

10062.

18

30 A 2P

9202030

4694.

18

60 A 2P

9202060

5954.

18

75 A 2P

9202075

5954.

18

100 A 2P

9202100

6194.

18

150 A 2P

9202150

9242.

18

200 A 2P

9202200

10882.

18

225 A 2P

9202225

11875.

18

30 A 3P

9203030

5436.

18

60 A 3P

9203060

7638.

18

9203075

7638.

18

9203100

9184.

18

150 A 3P

9203150

12998.

18

200 A 3P

9203200

14434.

18

225 A 3P

9203225

15750.

18

a
b
c

Ampacity
MLO

Tin or Silver Plating
100 A

1240.

510. e

1240.

610. e

400 A

2080.

830.

600 A

2080.

800 A
1200 A

125 A
225 A
250 A

d
e
f
g
h

44

56
62

2-pole

3-pole

560.
662.
786.
1094.
1320.

662.
858.
858.
1238.
1442.

Split Bus
7.5 in.
9 in.
12 in.
12 in.
18 in.

Main Circuit Breaker Without Overload Trip
(Automatic Molded Case Switch)

•

(Not UL Listed)
$ Price as standard main circuit breaker, no $ Price Adder.

Shunt Trip Circuit Breakers

•

See Digest page 7-35 for pricing.

Note: For molded case switch and automatic molded case switch short circuit current ratings,
See Digest page 7-33.

Special Features
For information on the following special features, please see the
Supplemental and Obsolescence Digest.
• Powerlogic™ metering k
• Customer equipment space (NQ and NF) k
• Increased box depth k
• Increased gutters–top, bottom, and sides k
• Non-standard paint k
• Welded base channel k
• Type 1 gasketed k
• Type 2 drip hood k
• Type 3R/4/4X/5/12 stainless steel enclosure k
• Type 4X fiberglass enclosure k
• Stainless steel trim front k
• Padlockable hasp k
• Special locks (Corbin, Yale, Best) k
• Equal height boxes k
• Common trim to cover two equal height boxes k
• Panelboard skirt—hides conduits feeding a panelboard k
• Panelboard wireway—for terminating conduit in wireway endwall k
• Keyed mechanical interlocking of two or more circuit breakers
(I-Line and QMB) k
• Motor operators (I-Line only)
• Panelboard interiors and special fronts to fit existing boxes
• A standard panelboard box has one blank endwall and one with
knockouts. Blank endwalls or knockouts in both endwalls are also
available k

750 A/in2 Al

340. f
456. f
572. f

1050. f

1080. fg

2080.

1490.

1244. g

2080.

1710.

1432. gh

Standard copper bus plating material
– NQ and NF: Silver plated bus/tin plated connectors
– I-Line and QMB: Tin.
NQ available in 42 circuit only.
Not available in NQ.
HCN 600 A and all 800–1200 A I-Line interiors available with copper bus only.
1200 A QMB with current density-rated bussing not available.

k

9-38

Box Height
(ft.)

Note: For applications with main circuit breaker panelboards, contact your local
Schneider Electric representative or distributor.
j
For I-Line panelboards, dimension includes height of “SL” sub-feed lug kit from Digest,
plus 3 in. from available branch mounting space.

Current Density Rated Bus
$ List Price Adder
1000 A/in2 Cu

Split

Additional Mounting Height
Required On Split Bus Section j

$ Price

225 A
400 A
600 A
800 A
1200 A

Table 9.180: Current Density Rated Panelboard Bus and
Special Plating for Copper Bus
Copper Bus Special
Plating
$ List Price Adder d

Main

Table 9.182: I-Line™ Panelboard Split Bus Bars

NF panels require 18 in. of additional box height regardless of contactor ampacity or
manufacturer.
If two-wire control is required—Square D™ brand. Add 708. (No additional width or
depth required)
If two-wire control is required—ASCO type. Add 1412. (No additional width or
depth required)

Ampacity

3-phase

When greater than 125 A lugs are required on the split section of the bus, contact your
local Schneider Electric representative or distributor for the box height.

ASCO Type 920 c

75 A 3P

1-phase

NQ Panelboards—125 A Maximum Lugs on Split Bus Section i
18
30
225 A
600.
900.
18
30
30
NF Panelboards—125 A Maximum Lugs on Split Bus Section i
18
30
250 A
—
900.
18
30
30
i

100 A 3P

Maximum Number of
Pole Spaces Available

$ List Price Adder

PE1

Discount
Schedule

Supported by the Panelboard Product Selector.
© 2012 Schneider Electric
All Rights Reserved

Panelboards

NQ and NF Terminal Data
Class 1640, 1670, / Refer to Catalog 1670CT0701, 1640CT0801

www.schneider-electric.us

Table 9.183: NQ Standard Aluminum Mechanical Lugs—Main Lugs

NQ

Ampere Rating

Lug Wire Range

100 A

one #6-2/0 Al or Cu

225 A

one #6-350 kcmil Al or Cu

400 A

one 1/0-750 kcmil or
two 1/0-350 kcmil Al or Cu

600 A

two 1/0-750 kcmil Al or Cu

PANELBOARDS

Panel Type

Panel Type

Ampere Rating
100 A

QOB

Lug Wire Range a
one #4–#2/0 Al or Cu

FI

one #14–#1/0 Al or Cu

150 A

HD, HG, HJ, HL

one #14–#3/0 Al or Cu

225 A

QB, QD, QG, QJ

one #4-300 kcmil Al or Cu

JD, JG, JJ, JL

NQ
250 A

a

Circuit Breaker
Type

9

Table 9.184: NQ Standard Aluminum Mechanical Lugs—Main Circuit Breaker

one #3/0–350 kcmil Al or Cu a

DJ

one #2–600 Cu or #2–500 Al

KI

one #1/0–350 kcmil Al or Cu

400 A

LA, LH

one #1–600 kcmil Al or Cu or
two #1–250 kcmil Al or Cu

600 A

LC

two #4/0-500 kcmil Al or Cu

The lug range shown is for the highest amperage of the circuit breaker frame shown in the table.

Table 9.185: NF Standard Mechanical Lugs—Main Lugs
Panel Type

Ampere Rating
125 A

NF

Lug Wire Range
one #6–2/0 Al or Cu

250 A

one #6–350 kcmil Al or Cu

400 A

one #1/0–750 kcmil or two #1/0–350 kcmil Al or Cu

600 A

two #1/0–600 kcmil Al or Cu

800 A

three #4/0–500 kcmil Al or Cu

Table 9.186: NF Standard Mechanical Lugs—Main Circuit Breaker
Panel Type

NF

b

© 2012 Schneider Electric
All Rights Reserved

Ampere Rating

Circuit Breaker Type

125 A

ED, EG, EJ

100 A

FI

150 A

HD, HG, HJ, HL
JD, JG, JJ, JL

250 A

Lug Wire Range b
one #14–#2/0 Al or Cu
one #14–#1/0 Cu or one #12–#1/0 Al
one #14–#3/0 Al or Cu
one #3/0–350 kcmil Al or Cu b

DJ

one #2–600 Cu or #2–500 Al

KI

one #1/0–350 kcmil Al or Cu

400 A

LA, LH

600 A

LC, LI, LE, LX, LXI

one #1–600 kcmil or two #1–250 kcmil Al or Cu
two #4/0–500 kcmil Al or Cu

The lug range shown is for the highest amperage of the circuit breaker frame shown in the table.

9-39

I-Line™ and QMB

Terminal Data
Class 2110, 4620 / Refer to Catalog 2110CT9701, 4620CT9601
www.schneider-electric.us

9

Table 9.187: Standard Mechanical Lugs—Main Lugs
Panel
Type

Ampere
Rating
100 A
225 A
400 A
600 A
800 A
1200 A

I-Line

Lug Wire Range a

PANELBOARDS

—
one #6–300 kcmil Al or Cu
two #2–600 kcmil Al or Cu
two #2–600 kcmil Al or Cu
(4) 3/0–750 kcmil Al or Cu
(4) 3/0–750 kcmil Al or Cu

Wire Range
Wire Bending Space per NEC Table 373-6 a
—
one #6–300 kcmil Al or Cu
one #2–600 kcmil Al or Cu
two #2–500 kcmil Al or Cu
(3) 3/0–500 kcmil Al or Cu
(4) 3/0–500 kcmil Al or Cu

Table 9.188: Standard Mechanical Lugs—Main Circuit Breaker
Panel
Type

I-Line

Ampere
Rating
100 A
150 A
225 A
250 A
400 A
600 A
800 A
1200 A

Circuit Breaker
Type
FA, FH, FI
HD, HG, HJ, HL
KI
JD, JG, JJ, JL
LX, LXI, LE
LA, LH
LC, LI, LX, LXI, LE
MG, MJ, PG, PJ, PL
PG, PJ, PL, RGC, RJC, RLC

Lug Wire Range a
one #14-1/0 Al or Cu
one #14-3/0 Al or Cu
one #4-300 kcmil Al or Cu
one #1/0-#4/0 Al or Cu
two #1-350 kcmil Al or Cu
one #1-600 or two #1-250 kcmil Al or Cu
two 4/0-500kcmil Al or Cu
three 3/0-500 kcmil Al or Cu
four 3/0-500 kcmil Al or Cu

Wire Range
Wire Bending Space per NEC Table 373-6 a
one #14-1/0 Al or Cu
one #14-3/0 Al or Cu
one #4-300 kcmil Al or Cu
one #1/0-300 kcmil Al or Cu
two #1-350 kcmil Al or Cu
one #1-600 kcmil Al or Cu
two 4/0-500kcmil Al or Cu
three 3/0-500 kcmil Al or Cu
four 3/0-500 kcmil Al or Cu

Table 9.189: Standard Mechanical Lugs—Main Lugs
Panel
Type

Mains
Ampere
Rating
225 A
400 A
600 A

QMB

800 A
1200 A
1600 A

Lug Wire Range a

Wire Range
Wire Bending Space per NEC Table 373-6 a

one #6–300 kcmil Al or Cu
one #6–300 kcmil Al or Cu and,
one 3/0–750 kcmil Al or Cu
two 3/0–500 kcmil Al or Cu

one #6–300 kcmil Al or Cu
one #6–300 kcmil Al or Cu and,
one 3/0–750 kcmil Al or Cu
two 3/0–500 kcmil Al or Cu
(3) 3/0–500 kcmil Al or Cu or
(4) 3/0–750 kcmil Al or Cu
two 3/0–750 kcmil Al or Cu
(4) 3/0–500 kcmil Al or Cu or
(4) 3/0–750 kcmil Al or Cu
(4) 3/0–750 kcmil Al or Cu
VCEL compression lugs Standard.

Table 9.190: Standard Mechanical Lugs—Main Switch
Panel
Type

QMB

Mains
Ampere
Rating
200 A
400 A
600 A
800 A

Lug Wire Range a

Wire Range
Wire Bending Space per NEC Table 373-6 a

#4–300 kcmil Al or Cu
3/0–600 kcmil Al or Cu
3/0–600 kcmil Al or Cu
3/0–600 kcmil Al or Cu

one #4–300 kcmil Al or Cu
two 3/0–600 kcmil Al or Cu
two 3/0–600 kcmil Al or Cu
(3) 3/0–500 kcmil Al or Cu

Table 9.191: Standard Mechanical Lugs—QMB Branch Switch Units
Panel
Type

QMB

Switch
Ampere
Rating
30 A
60 A
100 A
200 A
400 A
600 A
800 A

Lug Wire Range a

Wire Range
Wire Bending Space per NEC Table 373-6 a

one #14–#2 Al or Cu
one #14–#2 Al or Cu
one #14–1/0 Al or Cu
one #4–300 kcmil Al or Cu
two 3/0–600 kcmil Al or Cu
two 3/0–600 kcmil Al or Cu
(3) 3/0–600 kcmil Al or Cu

one #14–#2 Al or Cu
one #14–#2 Al or Cu
one #14–1/0 Al or Cu
one #4–300 kcmil Al or Cu
two 3/0–500 kcmil Al or Cu
two 3/0–500 kcmil Al or Cu
(3) 3/0–500 kcmil Al or Cu

Table 9.192: Standard Mechanical Lugs—QMJ Branch Switch Units b
Panel
Type

QMJ

a
b

9-40

Switch
Ampere
Rating
30 A
60 A
100 A
200 A
400 A
400 A
600 A

Lug Wire Range a

Wire Range
Wire Bending Space per NEC Table 373-6 a

one #14–#2 Al or Cu
one #14–#2 Al or Cu
one #14–1/0 Al or Cu
one #6–300 kcmil Al or Cu
one 1/0–750 kcmil Al or Cu
two 1/0–300 kcmil Al or Cu
two 3/0–600 kcmil Al or Cu

one #14–#2 Al or Cu
one #14–#2 Al or Cu
one #14–1/0 Al or Cu
one #6–300 kcmil Al or Cu
one 1/0–750 kcmil Al or Cu
two 1/0–300 kcmil Al or Cu
two 3/0–600 kcmil Al or Cu

(#) = Number of conductors per phase.
Use only 90 oC insulated conductors based on an ampacity of 75 oC conductors.

© 2012 Schneider Electric
All Rights Reserved

I-Line™ Combo
Panelboard

Combination Panelboards

www.schneider-electric.us

Part Number

Panelboard
Ampacity

List
$ Price

Single/
Duplex

Lighting
Section
Type

Lighting Lighting
Section
Section
Amperage Circuits

Busing

Ground Bar

Box

4 Piece Trim
Without Door

Trim with Door

NEMA 3R/5/12
(Includes
Fromnt)

18
18
18
18
18
18
18
18
18
18
18
18

CP18864N3Q2C
CP18864N3Q2
CP18864N4Q2C
CP18864N4Q2
CP18864N3F2C
CP18864N3F2
CP18864N4F2C
CP18864N4F2
CP18866N3Q4C
CP18866N4Q4C
CP18866N3F4C
CP18866N4F4C

400
400
400
400
400
400
400
400
600
600
600
600

10334.00
7650.00
10729.00
8045.00
17549.00
14749.00
18147.00
15388.00
15032.00
15428.00
21270.00
21863.00

S
S
S
S
S
S
S
S
S
S
S
S

NQ
NQ
NQ
NQ
NF
NF
NF
NF
NQ
NQ
NF
NF

225
225
225
225
250
250
250
250
400
400
400
400

30
30
42
42
30
30
42
42
30
42
30
42

Cu
Al
Cu
Al
Cu
Al
Cu
Al
Cu
Cu
Cu
Cu

PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU

HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB
HC2686DB

HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P
HC2686T( )4P

HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR
HC2686T( )HR

HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP
HC2686WP

22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5

CP23734N3Q2C
CP23734N3Q2
CP23734N3F2C
CP23734N3F2
CP23736N3Q4C
CP23736N3F4C
CP23914N4Q2C
CP23914N4Q2
CP23914N5Q2C
CP23914N5Q2
CP23914N4F2C
CP23914N4F2
CP23914N5F2C
CP23914N5F2
CP23916N4Q4C
CP23916N5Q4C
CP23916N4F4C
CP23916N5F4C
CP23916N44Q4C
CP23916N53Q4C

400
400
400
400
600
600
400
400
400
400
400
400
400
400
600
600
600
600
600
600

10686.00
7942.00
18065.00
15249.00
16159.00
22539.00
11091.00
8346.00
11604.00
8797.00
18672.00
15855.00
19341.00
16508.00
16563.00
17076.00
23145.00
23814.00
26032.00
26141.00

S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
D
D

NQ
NQ
NF
NF
NQ
NF
NQ
NQ
NQ
NQ
NF
NF
NF
NF
NQ
NQ
NF
NF
NQ
NQ

225
225
250
250
400
400
225
225
225
225
250
250
250
250
400
400
400
400
400
400

30
30
30
30
42
42
42
42
54
54
42
42
54
54
42
54
42
54
42/42
54/30

Cu
AL
Cu
AL
Cu
Cu
Cu
Al
Cu
Al
Cu
Al
Cu
Al
Cu
Cu
Cu
Cu
Cu
Cu

PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTA
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU

HC3273DB9
HC3273DB9
HC3273DB9
HC3273DB9
HC3273DB9
HC3273DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9
HC3291DB9

HCM73T( )V
HCM73T( )V
HCM73T( )V
HCM73T( )V
HCM73T( )V
HCM73T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V
HCM91T( )V

HCM73T( )VD
HCM73T( )VD
HCM73T( )VD
HCM73T( )VD
HCM73T( )VD
HCM73T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD
HCM91T( )VD

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5

CP32866N44Q4C
CP32866N53Q4C
CP32866N4BQ4C
CP32866N44F4C
CP32866N53F4C
CP32866N4BF4C
CP32868N44Q6C
CP32868N53Q6C
CP32868N3BQ6C
CP32868N4BQ6C
CP32868N5BQ6C
CP32868N44F6C
CP32868N53F6C
CP32868N3BF6C
CP32868N4BF6C
CP32868N5BF6C

600
600
600
600
600
600
800
800
800
800
800
800
800
800
800
800

26066.00
26170.00
18362.00
38703.00
38763.00
24681.00
36447.00
36552.00
23026.00
23415.00
23300.00
38744.00
38805.00
23981.00
24563.00
24599.00

D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D

NQ
NQ
NQ
NF
NF
NF
NQ
NQ
NQ
NQ
NQ
NF
NF
NF
NF
NF

400
400
400
400
400
400
600
600
600
600
600
600
600
600
600
600

42/42
54/30
42/O
42/42
54/30
42/O
42/42
54/30
30/O
42/O
54/O
42/42
54/30
30/O
42/O
54/O

Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu
Cu

PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU
PK32DGTACU

HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB
HC4486DB

HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )
HCR86T( )

HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D
HCR86T( )D

HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP
HC4486WP

9

I-Line
Mounting
Space

Table 9.194: RTI Cabled Lighting Section Kit for I-Line Combo Panelboard
Part Number

Description

MLO Panelboard
Ampacity

List
$ Price

Lighting
Section
Type

Lighting
Section
Circuits

NFICRT418L1C

NF Lighting Section Kit

125

1528.00

NF

18

NFICRT442L2C

NF Lighting Section Kit

250

1763.00

NF

42

NFICRT442L4C

NF Lighting Section Kit

400

2353.00

NF

42

NFICRT442L6C

NF Lighting Section Kit

600

2008.00

NF

42

NQICRT418L1C

NQ Lighting Section Kit

100

1564.00

NQ

18

NQICRT442L2C

NQ Lighting Section Kit

225

1373.00

NQ

42

NQICRT442L4C

NQ Lighting Section Kit

400

2156.00

NQ

42

NQICRT442L6C

NQ Lighting Section Kit

600

2332.00

NQ

42

NQICRT418C1C

Contactor with 18 Circuit NQ Lighting Section Kit

100

1225.00

NQ

18

NFICRT418C1C

Contactor with 18 Circuit NF Lighting Section Kit

125

1440.00

NF

18

© 2012 Schneider Electric
All Rights Reserved

PANELBOARDS

Table 9.193: Interior Boxes and Fronts — Includes Solid Neutral

9-41

Series Ratings

NQ Panelboards
Class 1640
www.schneider-electric.us

9

This page contains UL Tested and Certified series combination ratings for
panelboards. These ratings apply to either an integral main located in the
same enclosure or a remote main located in a separate enclosure.
Table 9.195: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)

PANELBOARDS

Square D™ Brand
Maximum Maximum
Short
Integral or Remote
System
Circuit Main Circuit Breakers
Voltage Current
and Remote Main
AC ab
Rating
Fuses
22,000

25,000

Type

1 Pole

2 Pole

3 Pole

QO (B)

15–30 A

—

—

LD, HD, JD

QO (B)
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
15–125 A
15–60 A
15–60 A
15–60 A
—
—

—
—
—
—
—
—
—

QO (B)
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
15–125 A
15–60 A
15–60 A
15–60 A
—
—

—
—
—
—
—
—
—

LG

QO (B)
QO (B) VH
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
15–125 A
15–60 A
15–60 A
—
—

—
—
—
—
—
—

LJ

QO (B) GFI
QO (B) EPD

15–30 A
15–30 A

40–60 A
40–60 A

—
—

HJ, JJ

QO (B)
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
15–125 A
15–60 A
15–60 A
15–60 A
—
—

—
—
—
—
—
—
—

QO (B)
QO(B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO(B) AFI
QO(B) CAFI

15–70 A
15–70 A
—
—
—
15–20 A
15–20 A

15–125 A
15–125 A
15–100 A
15–30 A
15–60 A
—
—

—
—
—
—
—
—
—

DJ 400 A

QO (B)
QO (B) VH
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
—
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
150 A
15–60 A
15–60 A
—
—

—
—
—
—
—
—

QJ

QO (B)
QO (B) AS
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
—
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
15–30 A
150 A
15–60 A
15–60 A
—
—

—
—
—
—
—
—
—

HL, JL

QO (B)
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
15–125 A
15–60 A
15–60 A
15–60 A
—
—

—
—
—
—
—
—
—

LA/LH (L) 34200MC
LA/LH (L) 34225MC
LA/LH (L) 34250MC
LA/LH (L) 34400MC

QO (B)

15–30 A

15–30 A

15–30 A

LD

QO (B)
QO (B) VH
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
15–30 A
15–30 A
—
15–20 A
15–20 A

15–125 A
—
15–125 A 15–150 A
15–60 A 15–30 A
15–60 A 15–30 A
—
15–30 A
—
—
—
—

DJ–W 150 A MC

QO (B)
QO (B) VH
QO (B) GFI
QO (B) AFI

15–70 A
—
15–30 A
15–20 A

15–100 A
—
15–125 A 15–150 A
15–60 A
—
—
—

DJ–W 250 A MC

QO (B)
QO (B) VH
QO (B) GFI
QO (B) AFI

15–70 A
—
15–30 A
15–20 A

15–100 A
—
—
15–150 A
15–60 A
—
—
—

QO (B)
QO (B) VH
QO (B) GFI
QO (B) AFI

15–70 A
—
15–30 A
15–20 A

15–100 A
—
—
15–150 A
15–60 A
—
—
—

65,000

120/240
1P/3W

LJ
100,000

125,000

18,000

25,000
208Y/120
3P/4W
240/120 V
3P/4W

30,000

DJ–W 600 A MC

Square D™ Brand
Maximum Maximum
Short
Integral or Remote
System
Circuit Main Circuit Breakers
Voltage Current
and Remote Main
AC ab
Rating
Fuses

100,000

240/120 V
3P/4W

240/120 V
3P/4W

a
b
c
d
e
f
g
h

9-42

Type

1 Pole

LG

15–70 A
15–70 A
—
15–30 A
15–30 A
—
15–20 A
15–20 A

15–125 A
—
15–125 A 15–150 A
15–100 A
—
15–60 A 15–30 A
15–60 A 15–30 A
—
15–30 A
—
—
—
—

LJ

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
—
15–30 A
15–30 A
—
15–20 A
15–20 A

15–125 A
—
15–125 A 15–150 A
15–100 A
—
15–60 A 15–30 A
15–60 A 15–30 A
—
15–30 A
—
—
—
—

LL

QO (B) GFI
QO (B) EPD
QO (B) EPE

—
—
—

DJ 400 A

QO (B)
QO (B) VH
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
—
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
—
—
15–150 A
15–60 A
—
15–60 A
—
—
—
—
—

QJ

QO (B)
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

15–70 A
—
15–30 A
15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A 15–30 A
—
15–150 A
15–60 A 15–30 A
15–60 A 15–50 A
15–60 A 15–50 A
15–60 A 15–50 A
—
—
—
—

LJ

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
—
—
—
15–20 A
15–20 A

15–125 A
—
15–125 A 15–150 A
15–100 A
—
15–30 A
—
15–60 A
—
—
—
—
—

QO (B) VH

QO (B)
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) PL
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
15–30 A
—
15–30 A
15–20 A
15–20 A

15–125 A 15–100 A
15–60 A 15–50 A
15–60 A 15–50 A
—
15–50 A
15–60 A
—
—
—
—
—

QD

QO (B)
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

15–70 A
—
15–30 A
15–30 A
15–30 A
—
15–20 A
15–20 A

15–125 A 15–30 A
—
35–150 A
15–60 A 15–30 A
15–60 A 15–50 A
15–60 A 15–50 A
—
15–50 A
—
—
—
—

ED, FD

QO (B)
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
15–20 A
15–20 A

15–125 A 15–100 A
15–60 A 15–50 A
—
—
—
—

KD

QO (B)
QO (B) AS
QO (B) GFI
QO (B) AFI

15–70 A
15–30 A
15–30 A
15–20 A

15–125 A 15–100 A
15–30 A 15–30 A
15–60 A
—
—
—

HD, JD

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

15–70 A
—
—
15–30 A
15–30 A
—
15–20 A
15–20 A

15–125 A 15–100 A
—
35–150 A
15–100 A
—
15–60 A 15–50 A
15–60 A 15–50 A
—
15–50 A
—
—
—
—

LD

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
—
15–30 A
15–30 A
—
15–20 A
15–20 A

15–125 A
—
15–125 A 15–150 A
15–100 A
—
15–60 A 15–30 A
15–60 A 15–30 A
—
15–30 A
—
—
—
—

65,000

208Y/120
3P/4W
240/120 V
3P/4W

22,000

Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef

MG

HG, JG

Table 9.195: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)

25,000

2 Pole

—
—
—

3 Pole

15–30 A
15–30 A
15–30 A

For shown circuit breakers rated less than this maximum voltage, the indicated short
circuit current rating also applies, but at the voltage rating of the circuit breaker
Short circuit tests are conducted at 100–105% of the maximum rated voltage of the
panelboard.
Suffixes HID, and SWD may also be applied to the applicable branch circuit breakers
shown above. Suffix SWN may not be applied in combination with LC main breakers.
Where QO (B) circuit breakers are shown above, QO (B) H, QO (B) VH, and QOH (B)
circuit breakers may also be used.
Where QO (B) GFI circuit breakers are shown above, QO (B) EPD and/or QO (B) EPE
circuit breakers may also be used. QO–EPE only comes in 3 pole construction.
Where QO (B) AFI circuit breakers are shown above, QO (B) CAFI circuit breakers may
also be used.
To achieve selective coordination, the rating of the DJ main circuit breaker must be at
least two times greater than the ampere rating of any branch circuit breaker.
For complete series ratings for Delta Systems please reference NQ/NQM Panelboards
Information Manual 80043–712–06.
© 2012 Schneider Electric
All Rights Reserved

Series Ratings

NQ Panelboards
Class 1640

www.schneider-electric.us

Table 9.196: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef
Type

1 Pole

LA, MA

Q2L–H
QDL

—
—

100–225 A 100–225 A
70–225 A 70–225 A

LC400A

QO (B)
QO (B) VH
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
15–30 A
15–20 A
15–20 A

15–70 A
—
15–125A 15–100 A
15–60 A 15–30 A
—
—
—
—

LC600A

QO (B) VH
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
15–20 A
15–20 A

15–125 A 15–100 A
15–60 A 15–30 A
—
—
—
—

MG

QO (B) VH

15–30 A

15–30 A

LC400A

QO (B)
QO (B) VH
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

15–30 A
—
15–125 A 15–100 A
15–60 A
—
—
—
—
—

QO (B) VH
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–30 A
—
15–20 A
15–20 A

15–125 A 15–150 A
—
15–30 A
—
—
—
—

QO (B)
QO (B) VH
QO (B) H
QO (B)
QO (B) VH
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–70 A 15–125 A
—
—
—
15–150 A
—
15–100 A
—
15–70 A 15–150 A
—
—
110–125 A 15–150 A
15–30 A 15–60 A
—
15–20 A
—
—
15–20 A
—
—

42,000

LC600A

DJ400A

DJ_W

2 Pole

3 Pole

QO (B) EPD

—

EG, FG, KG

QO (B)
QO (B) GFI
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
15–20 A
15–20 A

15–125 A 15–100 A
15–60 A
—
—
—
—
—

QG

QO (B)
QO (B) VH
QO (B) GFI
QO (B) PL
QO (B) AFI
QO (B) CAFI

15–70 A
—
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A 15–30 A
—
35–150 A
15–60 A 15–50 A
15–60 A 15–30 A
—
—
—
—

HG, JG

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) PL
QO (B) AFI
QO (B) CAFI

15–70 A
—
—
15–30 A
15–30 A
—
15–30 A
15–20 A
15–20 A

15–125 A 15–100 A
—
35–150 A
15–100 A
—
15–60 A 15–50 A
15–60 A 15–50 A
—
15–50 A
15–60 A 15–30 A
—
—
—
—

FC_ or KC_22___
FC_ or KC_34___

QO (B)
QO (B) AS

15–70 A
15–30 A

15–100 A 15–100 A
15–30 A 15–30 A

LG

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
—
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
—
15–125 A 15–150 A
15–100 A
—
15–60 A 15–30 A
15–60 A 15–30 A
—
—
—
—

LJ

QO (B)
QO (B) GFI
QO (B) EPD
QO (B) EPE

15–70 A
15–30 A
15–30 A
—

15–125 A
40–60 A
40–60 A
—

—
—
15–30 A
15–30 A

LL

QO (B) EPD
QO (B) EPE

—
—

—
—

15–30 A
15–30 A

FC_ or KC_22___
FC_ or KC_34___

QO (B) GFI
QO (B) AFI

15–30 A
15–20 A

15–30 A
—

—
—

DJ400A

QO (B)
QO (B) H
QO (B) VH
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
—
—
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A
—
15–100 A
—
—
15–150 A
15–60 A
—
15–60 A
—
—
—
—
—

240/120 V
3P/4W

EJ

QO (B)

15–70 A

15–125 A 15–100 A

LJ

QO (B)
QO (B) VH
QO (B) H
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–70 A
—
—
—
15–20 A
15–20 A

15–125 A
—
15–125 A 15–150 A
15–100 A
—
15–30 A
—
15–60 A
—
—
—
—
—

HJ, JJ

QO (B)
QO (B) H
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
—
—
15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A 15–100 A
15–100 A
—
—
35–150 A
15–60 A 15–30 A
15–60 A 15–50 A
15–60 A 15–50 A
—
—
—
—

100,000

© 2012 Schneider Electric
All Rights Reserved

15–30 A

e
f

3 Pole

QO (B)
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–70 A
15–30 A
15–30 A
15–20 A
15–20 A

15–125 A 15–100 A
15–60 A
—
15–60 A
—
—
—
—
—

200 A Max. Class T6,
J Fuses

QO (B)
QO (B) GFI
QO (B) EPD

15–70 A
—
—

15–125 A
—
—

400 A Max. Class T3
Fuses

QO (B)
QO (B) GFI
QO (B) EPE
QO (B) EPD

15–70 A
15–30 A
—
15–30 A

15–125 A 15–100 A
15–60 A 15–50 A
—
15–50 A
15–60 A 15–50 A

42,000

400 A Max. Class T3
Fuses

QO (B) VH

15–30 A

15–125 A

—

50,000

400 A Max. Class T3
Fuses

QO (B) VH

—

—

15–30 A

400 A Max. Class J
Fuses

QO (B) VH
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI

15–70 A
—
—
15–20 A
15–20 A

15–125 A
—
—
—
—

—
15–50 A
15–50 A
—
—

400 A Max. Class T6
Fuses

QO (B) VH
QO (B) AFI

15–70 A
15–20 A

15–125 A 15–150 A
—
—

200 A Max. Class
T3 Fuses

QO (B)
QO (B) VH
QO (B) GFI
QO (B) EPD
QO (B) EPE
QO (B) AFI
QO (B) CAFI
QOT

15–70 A
—
15–30 A
15–30 A
—
15–20 A
15–20 A
15–30 A

15–125 A 15–100 A
—
15–30 A
15–60 A
—
15–60 A 15–50 A
—
15–50 A
—
—
—
—
15–30 A
—

200 A Max. Class J or
T6 Fuses

QO (B) EPD
QO (B) EPE

—
—

400 A Max. Class T3
Fuses

QO (B)
QO (B) GFI
QO (B) EPD
QO (B) EPE

15–70 A
15–30 A
15–30 A
—

200,000

200,000

d

2 Pole

FI, KI, HR, JR

100,000

c

15–125 A 15–100 A
15–100 A
—
—
35–150 A
15–60 A 15–30 A
15–60 A 15–50 A
15–60 A 15–50 A
—
—
—
—

200,000

240/120 V
3P/4W

b

1 Pole
15–70 A
—
—
15–30 A
15–30 A
15–30 A
15–20 A
15–20 A

HL, JL

65,000

a

Type

125,000
240/120 V
3P/4

208Y/120
3P/4W

Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef

QO (B)
QO (B) H
QO (B) VH
QO (B) PL
QO (B) GFI
QO (B) EPD
QO (B) AFI
QO (B) CAFI

15–30 A

DJ, DG, DL 150–600 A

65,000

—

Square D™ Brand
Maximum Maximum
Short
Integral or Remote
System
Circuit Main Circuit Breakers
Voltage Current
and Remote Main
AC ab
Rating
Fuses

—
—

—
15–50 A
15–50 A

15–50 A
15–50 A

15–125 A 15–100 A
15–60 A
—
15–60 A 15–50 A
—
15–50 A

For shown circuit breakers rated less than this maximum voltage, the indicated short
circuit current rating also applies, but at the voltage rating of the circuit breaker.
Short circuit tests are conducted at 100–105% of the maximum rated voltage of the
panelboard.
Suffixes HID, SWD, and SWN may also be applied to the applicable branch circuit
breakers shown above. Suffix SWN may not be applied in combination with LC main
breakers.
Where QO (B) circuit breakers are shown above, QO (B) H, QO (B) VH, and QH (B)
circuit breakers may also be used.
Where QO (B) GFI circuit breakers are shown above, QO (B) EPD circuit breakers may
also be used.
To acheive selective coordiantion, the rating of the DJ main circuit breaker must be at
least two times greater than the ampere rating of any branch circuit breaker.

This page last modified
5/14/14

PANELBOARDS

Square D™ Brand
Maximum Maximum
Short
Integral or Remote
System
Circuit Main Circuit Breakers
Voltage Current
and Remote Main
AC ab
Rating
Fuses

9-43

9

Table 9.196: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)

NQ Merchandised
Panelboards

NQ Merchandised Accessories
Class 1640
www.schneider-electric.us

9

Table 9.197: NQ SurgeLogic SurgeLoc Plug-on SPDab
Voltage

Part Number

List
$ Price

Poles Occupied

PANELBOARDS

80 kA
SSP01BIA08PBQ1
4200.
100 kA
SSP01BIA10PBQ1
4500.
120 kA
SSP01BIA12PBQ1
4800.
120 / 240 V
12
160 kA
SSP01BIA16PBQ1
5300.
200 kA
SSP01BIA20PBQ1
6500.
240 kA
SSP01BIA24PBQ1
7900.
80 kA
SSP02BIA08PBQ1
4400.
100 kA
SSP02BIA10PBQ1
4700.
120 kA
SSP02BIA12PBQ1
5100.
208 Y / 120 V
12
160 kA
SSP02BIA16PBQ1
5550.
200 kA
SSP02BIA20PBQ1
7000.
240 kA
SSP02BIA24PBQ1
8250.
80 kA
SSP03BIA08PBQ1
4400.
100 kA
SSP03BIA10PBQ1
4700.
120 kA
SSP03BIA12PBQ1
5100.
240 / 120 HLD
12
160 kA
SSP03BIA16PBQ1
5550.
200 kA
SSP03BIA20PBQ1
7000.
240 kA
SSP03BIA24PBQ1
8250.
a
When selecting a panelboard with SurgeLoc SPD, an additional 12 circuit positions (6
adjacent mounting spaces per side) are occupied. For example, if the desired number of
circuits is 30, refer to Digest Table 9.9 on page 6 and Table 9.10 on page 7 to select the
NQ442L2/NQ442L2C interior and corresponding Box and Trim.
b
SPD is only available up to 72 desired circuit counts.

9-44

© 2012 Schneider Electric
All Rights Reserved



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:06:02 10:56:14-04:00
Modify Date                     : 2014:06:02 10:56:14-04:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:06:02 10:56:14-04:00
Format                          : application/pdf
Document ID                     : uuid:790eea13-29f4-480d-8f3f-3295b7e0ecdc
Instance ID                     : uuid:29bd570f-b76b-4997-8d10-8332598c714e
Page Mode                       : UseOutlines
Page Count                      : 44
EXIF Metadata provided by EXIF.tools

Navigation menu