108265 Catalog
118074-Attachment 118074-Attachment 118074-Attachment 785901 Batch6 unilog cesco-content
119478-Catalog 119478-Catalog 119478-Catalog 785901 Batch7 unilog cesco-content
106007-Catalog 106007-Catalog 106007-Catalog 785901 Batch8 unilog cesco-content
2014-07-05
: Pdf 108265-Catalog 108265-Catalog 785901 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 44
Download | |
Open PDF In Browser | View PDF |
Table of Contents Section 9 Panelboards NQ NF I-Line™ 9-2, 9-42 9-3 9-3 Lighting and Appliance Panelboards NQ/NF NQ NQ Panelboards Page 9-5 NF Panelboards Page 9-13 Pricing Procedure Merchandised Main Lug Panelboards Merchandised Main Circuit Breaker Panelboards Merchandised 14-inch-wide Panelboards Merchandised Accessories QOB Branch Circuit Breakers Factory Assembled Panelboards and Circuit Breakers Factory Assembled Common Features NF Merchandised Main Lugs Panelboards Merchandised Main Circuit Breaker Panelboards Merchandised Main Lug and Main Circuit Breaker Panelboards with Merchandised Accessories EDB, EGB, EJB Branch Circuit Breakers Factory Assembled Panelboards Factory Assembled Common Features NQ/NF Merchandised Single Row (Column Width) Panelboards Column Width Factory Assembled Single Row (Column Width) Panelboards 9-5 9-6 9-7 9-8 9-9 9-10 9-11 9-12 9-13 9-13 9-13 9-14 9-15 9-16 9-17 9-18 9-19 Power Distribution Panelboards—Circuit Breaker Type I-Line/QMB I-Line I-Line Panelboards Page 9-20 Pricing Procedure Merchandised Panelboards (HCN, HCM, HCP-SU) Merchandised Panelboards (HCP, HCR-U) Merchandised Accessories Circuit Breakers F-frame Circuit Breakers Q-frame Circuit Breakers H-frame and J-frame Circuit Breakers K-frame Circuit Breakers L-frame Circuit Breakers M-frame Circuit Breakers P-frame and R-frame Circuit Breakers Factory Assembled Pricing Factory Assembled Branch Circuit Breakers Factory Assembled Common Features 9-20 9-21 9-22 9-23 9-24 9-24 9-25 9-26 9-27 9-28 9-29 9-30 9-31 9-32 9-34 Power Distribution Panelboards—Fusible Type QMB Replacement Switches Factory Assembled Pricing Factory Assembled SPD Units 9-35 9-36 9-37 Panelboard Special Features QMB Panelboards Page 9-35 © 2012 Schneider Electric All Rights Reserved Factory Assembled Modifications Terminal Data 9-38 9-39 9-1 9 Series Rated / Fully Rated Tables PANELBOARDS ,x Series Ratings NQ Panelboards Class 1640 www.schneider-electric.us 9 This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located in the same enclosure or a remote main located in a separate enclosure. Table 9.1: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical) PANELBOARDS Square D™ Brand Maximum Maximum Short Integral or Remote System Circuit Main Circuit Breakers Voltage Current and Remote Main AC ab Rating Fuses Square D™ Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges cdef Type 1 Pole 2 Pole 3 Pole NOTE: Table 9.1 NQ Series Connected Circuit Breaker Ratings table has moved to page 9-42 and page 9-43. 9-2 © 2012 Schneider Electric All Rights Reserved Series Ratings NF and I-Line™ Panelboards Class 2110 / Refer to Catalog 2110CT9701 Table 9.2: NF Series Connected Circuit Breaker Ratings (RMS Symmetrical) Max. Maximum Short System Circuit Voltage, Current AC a Rating Square D™ Brand Integral or Remote Main Circuit Breakers and Remote Main Fuses Square D™ Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges EG, FH, FG, KH, LH, MH, MX, HG, JG, DG LG EG EJ, FC, FJ, KC, LC, HJ, JJ 120 100,000 DJ, LJ 120/240 EJ, FC, KC, HJ, JJ 240 125,000 HL, JL FI, KI, LI, LXI, HR, JR, LR 200,000 FI, KI, HR, JR Class J or T (600 V) 200 A Max Fuses EG, FG, KH, LH, HG, JG, DG, LG 35,000 EG, HG, JG EJ, FC, FJ, KC, LC, LX, HJ, JJ, DJ EJ, FC, KC, HJ, JJ 65,000 LJ 65,000 277 480Y/277 100,000 200,000 18,000 25,000 600Y/347 35,000 50,000 65,000 200,000 EDB, EDB-EPD EDB ECB-G3 EDB, EDB-EPD, EGB EDB, EGB ECB-G3 EDB, EDB-EPD, EGB, ECB-G3 EDB, EDB-EPD, EGB, EJB ECB-G3 ECB-G3 EDB, EDB-EPD ECB-G3 EDB, EDB-EPD, EGB ECB-G3 EDB, EDB-EPD, EGB, EGB-EPD LL EDB-EPD, EGB-EPD HL, JL EDB, EDB-EPD, EGB, EJB DL, LL EDB, EGB, EJB 400 A Max Fuses EDB, EDB-EPD, EGB, EJB FI, KI, LI, LXI, HR, JR, LR EDB, EDB-EPD, EGB, EJB FI, KI, HR, JR ECB-G3 200 A Max Fuses EDB, EDB-EPD, EGB, EJB, ECB-G3 HG, JG, MG, EDB LG EDB (15–110 A) EJ, FI, KH, KI, LC, LE, LX, LI, LXI, HJ, JJ EDB, EGB EDB (15–110 A), LJ EGB (15–110 A) LH (15–70 A) EDB, EGB LC, LE, LX EDB, EGB, EJB HL, JL, EDB, EGB, EJB EDB (15–110 A), EGB LL (15–110 A),EJB (15–110 A) FI, KI, HR, JR EDB, EGB, EJB LI, LXI, LR EJB Class J or T (600 V) 200 A Max Fuses EDB, EGB, EJB . Table 9.3: I-Line Series Connected Circuit Breaker Ratings (RMS Symmetrical) Max. Short Square D™ Brand Branch Circuit Breakers Maximum Circuit Integral or Remote System Current 2- or 3-pole Main Voltage Rating Designation Poles Circuit Breaker AC a (RMS Symm.) 42k MG FY 65k QG, LH FA, FDb FJb, QJ FDb 120 1 100k QJ, LC FA LJ FH 200k LR FH, FY QJ FA, FDb 208Y/120 100k 2, 3 QJ, PH, PJ, RJ QD, QG 35k MG FA 1 KA FDb 1, 2, 3 42k LA, MA HD, JD, QD 2, 3 MG FA 50k MG FA (25 A Max.) 1 HG, JG FA, HD JG JD, QD 2, 3 QG FA, FDb, QD LH, MH, PA, PG, RG HD, JD, QD FGb, FH, MH, MX, PJ FDb 65k FC, KC, KH, LC, LH FDb, FGb 1, 2, 3 LH FA LH LA MG HD, JD, KA LG HD, JD, KA, LA, LD, MA 2, 3 DG FH, HD, JD, KA, LA, MA 85k RL FH, KH 240 FC, KC, LC, LX FDb, FGb, FJ 1 PH, PJ, RJ QD, QG 2, 3 QJ FDb 2 FJb FDb FC, KC FA, FH, FDb, FGb, FJb LC, LX FH, FDb, FGb, FJb 2, 3 KC, LC, LX KA KC, LC KH LC LA, LH, MG 100k LC FA 1, 2, 3 HJ, JJ FA, FH, HD, HG JJ JD, JG LC, LX, MJ, PJ, RJ HD, HG, JD, JG MJ LA, LH LJ FH, HD, HG, JD, JG, KA, LA, LD, LG, MA, MG 2, 3 DJ FH, HD, HG, JD, JG, KA, LA, MA, MG RL RG HL, JL HD, HG, HJ, FA, H JL JD, JG, JJ PC, PH, PL, RL HD, HG, JD, JG 240 125k PC, PL, RL HH, JJ 2, 3 FI, KI, LI, LXI HD, HG, HJ KI, LI, LXI JD, JG, JJ Table 9.3: I-Line Series Connected Circuit Breaker Ratings (RMS Symmetrical) (continued) Max. Short Square D™ Brand Branch Circuit Breakers Maximum Circuit Integral or Remote System Current 2- or 3-pole Main Voltage Rating Designation Poles Circuit Breaker AC a (RMS Symm.) FI, KI, LI, LXI FDb, FGb, FJ 1 FI, KI FA, FH, FC, FDb, FGb, FJb LI, LXI FH, FDb, FGb, FJb 240 200k LI FC 2, 3 KI, LI, LXI KA, QD, QG, QJ LI KC LR FH, HJ, HL, JJ, JL, LA, LH, QD, QG, QJ 18k LD FY 25k FH, KA FDb FGb, KH, LH FDb 35k DG FH, FY LG FH, FY FJb FDb FC, KC FA, FH, FY, FDb, FGb LC, LX (400 A Max.) FH 65k LC, LX (600 A Max.) FY, FDb, FGb LJ FH, FY 277 1 DJ FH, FY LL FY DL FH, FJb 100k LL FH, FJb FI, KI FA, FH, FY, FDb, FGb, FJb HR FA, FJb, FY JR FA, FJb, FY 200k LI, LXI (400 A Max.) FH LI, LXI (600 A Max.) FY, FDb, FGb, FJb LR FH, FY 22k MG FA KH, LA, MA, MX, PA, FH PC, PX, PJ 30k LA, MA, PA, PC, PX KA LA, MA, PA HD, JD MG FA (25 A Max.), FH, KA MH, MX, PA HD, JD HG, JG FA, HD JG JD 35k LH, MG, PG, RG HD, JD LG FH, HD, JD, KA, LA, LD, MA DG FH, HD, JD, KA, LA, MA MJ FH (25 A Max.) 42k RL RG 50k MJ KA, KH FC, KC FA, FH HJ, JJ FA, FH, HD, HG JJ JD, JG LC, LI, LX, LXI HD, HG, JD, JG 65k LC, LX (400 A Max.) FH 480 KC, LC, LX KA LC, LX LA LJ FH, HD, HG, JD, JG, KA, LA, LD, LG, MA 2, 3 DJ FH, HD, HG, JD, JG, KA, LA, MA HL, JL FA, FH, HD, HG, HJ JL JD, JG, JJ JR FA LI, LXI (600 A Max.) KA 100k FH, HD, HG, HJ, JD, JG, JJ, KA, LA, LD, LG, LL LJ, MA DL FH, HD, HG, HJ, JD, JG, JJ, KA, LA, MA PC, PH, PL, RL HJ, JJ RL RG FI, KI FA, FH, FC, HD, HG, HJ HR FA, HD, HG, HJ, HL JR HD, HG, HJ, HL, JD, JG, JJ, JL 200k KI JD, JG, JJ, KA LI FC, KA, KC, LA, HJ, HL, JJ, JL LR FH, HJ, HL, JJ, JL, LA, LH LXI KA, HJ, HL, JJ, JL 25k FH, KA FDb 35k FGb, KH, LH FDb FJb FDb 480Y/277 65k FC, KC FDb, FGb LC, LX (600 A Max.) FDb, FGb FI, KI FDb, FGb, FJb 200k LI, LXI (600 A Max.) FDb, FGb, FJb HG, JG FA, HD JG JD 18k LG HD, JD, LD MG, PG, RG HD, JD MG FA HJ, JJ FA, HD, HG JJ JD 25k LJ HD, HG, JD, JG, LD, LG, MA PJ, RJ MG 35k LC FH, HD, HG, HJ, JD, JG, JJ, LA 600 2, 3 HL, JL FA, HD, HG, HJ JL JD, JG, JJ 50k LL HD, HG, HJ, JD, JG, JJ, LD, LG, LJ, MA PK HJ, JJ, MJ FI, KI HD, HG, HJ HR FA, HD, HG, HJ, HL JR FA, HD, HG, HJ, HL, JD, JG, JJ, JL 100k KI JD, JG, JJ KI, LI FH LI LA 18k MG FA (25 A max.) 600Y/347 25k MJ FA (30 A max.) 1 50k HL, JL FJ a Short circuit tests are conducted at 100–105% of the maximum rated voltage of the panelboard. b Obsolete. Contact your local Schneider Electric representative or distributor for the replacement circuit breaker. NOTE: LD, LG, LH, and LL breakers are only available in 3 pole configurations. © 2012 Schneider Electric All Rights Reserved 9-3 PANELBOARDS This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located in the same enclosure or a remote main located in a separate enclosure. 9 www.schneider-electric.us Series Ratings I-Line™ Panelboards Class 2110 www.schneider-electric.us 9 Table 9.4: Fuse/I-Line Circuit Breaker Series Connected Ratings Short Circuit Maximum System Max. Current Rating Voltage AC (RMS Symm.) PANELBOARDS 120/240 1Ø 208Y/120 100,000 240 65,000 Remote Main Fuse Maximum Amperage 1200 A 800 A 600 A 1200 A 800 A 600 A 1200 A 800 A 600 A 240 100,000 800 A 1200 A 1600/2000 A 4000 A Square D™ Brand Branch Circuit Breakers Fuse Class Designation a L, T (300 V) T (600 V) J, RK5 L, T (300 V) T (600 V) J, RK5 L, T (300 V) T (600 V) J, RK5 L, T (600 V) RK5 J T (600 V) T (300 V) L L T (600 V) L L QD, QG QD, QG QD, QG QD QD QD QD, QG (2-pole) QD, QG (2-pole) QD, QG (2-pole) FA, FH, KA, KH, KC, LA, LH, MA, MH, MX, PG FH, KA, KH, LA, LH, MA, MH, MX, PG, HD, HG, HJ, HL, JD, JG, JJ, JL HD, HG, HJ, HL, JD, JG, JJ, JL FH, KA, KH, LA, LH, MA, MH, MX, PG PG FH,KA,KH,LA,LH,MA,MH,MX,PG FH, KH, LA, LH, MA, MH, MX, PG HD, HG, HJ, HL, JD, JG, JJ, JL KH, MA, MH, MX, PG HD, HG, HJ, HL, JD, JG, JJ, JL FA( 3-pole only), FH, FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL FH, FC, HD, HG, HJ, HL, JD, JG, JJ, JL KH, KC, LA, LH, LC, MA, MH, MX, NC, NX, PG, PJ, PL HD, HG, HJ, HL, JD, JG, JJ, JL FH, FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL PG, PJ, PL FH,FC, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL FC, KH, KC, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL HD, HG, HJ, HL, JD, JG, JJ, JL NA, NC, NX, PJ, PL HD, HG, HJ, HL, JD, JG, JJ, JL HD, HG, HJ, HL, JD, JG, JJ, JL HJ, HL, JJ, JL FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ FC, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ HJ, HL, JJ, JL KC, LC, MA, MH, MX, NA, PG, PJ KC, LC, MH,MG, MJ, MX, NA, PG, PJ HJ, HL, JJ, JL HJ, HL FA, FH, FC, HJ, HL, JJ, JL, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL FA, FH, FC, HJ, HL, JJ, JL, KA, KH, KC, LA, LH, MA, MH, MX, NA, NC, NX FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL KA, KH, KC, LA, LH, MA, MH, MX, NA, NC, NX KC, LA, LH, LC, MA, MH, MX, MG, MJ, NC, NX, PG, PJ, PG, PJ, PL KA, KH, KC, LA, LH, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL KC, LC, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL NA, NC, NX HG, JG ( molded case switches ) HD, HG, HJ, HL, JD, JG, JJ, JL HJ, HL, JJ, JL MG, MJ MG, MJ MG, MJ MG, MJ J, T (600 V) 600 A 240 200,000 800 A 1200 A 1600/2000 A 4000 A 400 A 600 A 480 100,000 800 A 1200 A 1600 A 2000 A 4000 A 200 A 400 A 480 200,000 600 A 800 A a 600 100,000 600 200,000 1200 A 1600/2000 A 30 A 200 A 400 A 600 A 1200 A 600 A 800 A RK5 J T (600 V) T (300 V) L L T (600 V) L L J, T (600 V) J, RK5 J, T (600 V) RK5 L, T (600 V) L T (600 V) L L L RK5 J T(600V) J T (600V) RK5 T (300 V) T (600 V) L L L CC J J, T (600 V) R L J T (600 V) Series rating valid for 2-pole or 3-pole circuit breakers. Note: • The fuse used in this UL test is an envelope (umbrella) fuse. This fuse is designed as a “worst case’’ fuse. Thus, no matter what manufacturer’s fuse is used, the Square D™ brand circuit breaker is protected. • The line side fused switch may be in a separate enclosure or in the same enclosure as the loadside circuit breaker. A line side fused switch may be a submain, integral main, or remote main. A load side circuit breaker may be a branch, submain, or an integral main used on the load side of a remote main. This series combination short circuit current rating shall not exceed that of the line side fused switch. The charts apply to Square D™ brand load side circuit breakers only. However, the line side fuse ratings are independent of the fuse manufacturer. • Not applicable to Corner Grounded Systems. • Limiters used in Square D™ brand DSL and DSL II fused power circuit breakers are not class L fuses and do not have series ratings. 9-4 © 2012 Schneider Electric All Rights Reserved NQ and NF Panelboards Pricing Procedure and Examples www.schneider-electric.us NQ and NF Factory Assembled Pricing Procedure 1. List circuit breakers required, either plug-on or bolt-on. See the appropriate Digest pages for catalog numbers. 1. Select Base Price for main lugs or main circuit breaker from the Base Price Table. Include equipment ground bar when required. 2. Determine equivalent number of pole spaces required. 2. 3. Select proper main lug interior (from page 9-6) or main lug interior and main circuit breaker adapter kit (from page 9-7) based on equivalent number of poles and ampere rating. Interiors include solid neutral and are field convertible to top-feed. List Branch Circuit Breakers (either plug-on or bolt-on) and determine total spaces required. Select price from the Branch Circuit Breakers Table. Include space-only charge for future requirements. 3. If total spaces required exceeds the maximum listed, price as two or more panelboards and add price for sub-feed or feed-through lugs so installer can cable between sections. 4. Add price for special features from appropriate page. Contact your local Schneider Electric representative or distributor for additional special features. 5. For complete price, add all prices. Order by description. 4. Select enclosure from appropriate page. Type 1—Select box and front catalog number corresponding to interior catalog number. Type 3R, 5, 12—Select enclosure. Interior trim kit for Type 3R, 5, 12 is included with the enclosure. 5. For complete price, add the component prices. Include panelboard accessories. 6. Apply appropriate discount schedule. NOTE: Additional special price adders can be found in the Supplemental and Obsolescence Digest, Section 4. 6. Apply appropriate discount schedule. NQ Merchandised Pricing Example NQ Factory Assembled Pricing Example Table 9.5: Table 9.7: 208Y/120 Vac, 3Ø4W, 10 kA SCCR, 225 A, MLO, Type-1, surface-mount, bolt-on, branch circuit breakers, main sub-feed lugs Branches Page No. Catalog Number Spaces (20) 20/1 two 40/2 two 30/3 9-10 9-10 9-10 (20) QOB120 two QOB240 two QOB330 20 4 6 Total 30 795. 177. 585. 225 A MLO Interior Box Cover Sub-feed Lugs 9-6 9-6 9-6 9-6 NQ430L2 MH32 NC32S NQSFL2 – – – – 1215. 113. 527. 203. Total Price 3615. $ Price 208Y/120 Vac, 3Ø4W, 10 kA SCCR, 225 A, MLO, Type-1, surface-mount, bolt-on, branch circuit breakers, main sub-feed lugs Item Page No. 225 A MLO Base Price (20) 20/1 Bolt-on two 40/2 Bolt-on two 30/3 Bolt-on Sub-feed Lugs 9-11 9-11 9-11 9-11 9-12 928. 1360. 268. 704. 128. Total Price 3388. NF Merchandised Pricing Example NF Factory Assembled Pricing Example Table 9.6: Table 9.8: 480Y/277 Vac, 3Ø4W, 25 kA SCCR, fully rated, copper bus, 100 A, main circuit breaker, Type 1, flush-mount, bolt-on, branch circuit breakers Branches Page No. Catalog No. Spaces (13) 20/1 one 40/2 one 50/3 9-15 9-15 9-15 EGB14020 EGB24040 EGB34050 13 2 3 Total 18 3315. 776. 1131. Main circuit breaker adapter kit (less circuit breaker) Main circuit breaker 125 A MLO Cu Bus Int. Box Cover 9-13 N150MH – 780. 7-28 9-13 9-13 9-13 HGL36100 NF418L1C MH38 NC38F – – – – 1701. 1838. 113. 549. Total Price 10203. © 2012 Schneider Electric All Rights Reserved 9 NQ and NF Merchandised Pricing Procedure Example pricing only $ Price 480Y/277 Vac, 3Ø4W, 25 kA SCCR, fully rated, copper bus, 250 A, main circuit breaker, Type 1, flush-mount, bolt-on, branch circuit breakers Item Page No. 250 A Main Circuit Breaker Base Price Copper bus adder (13) 20/1 one 40/2 one 50/3 9-16 9-17 9-16 9-16 9-16 6180. 458. 4212. 746. 1264. Total Price 12860. $ Price Discount Schedule PANELBOARDS Classes 1640 and 1670 / Refer to Catalog 1670CT0701, 1640CT0801 $ Price 9-5 NQ Merchandised Panelboards NQ Main Lug Interiors—240 Vac, 48 Vdc Class 1640 / Refer to Catalog 1640CT0801 www.schneider-electric.us 9 Table 9.9: Pole Spaces Main Lug Interiors—Accepts plug-on and bolt-on circuit breakers Mains Rating Total Price Interior Front and Enclosure Type 1 Type 3R, 5,12 Catalog No. a Type 3R, 5, 12 Enclosure f Type 1 Enclosure Interior Only (Order Branch Circuit Breakers Separately) Box 20 in. W x 5.75 in. D b $Price Catalog No. $ Price Mono-Flat™ Front c Catalog No. Enclosure 20 in. W x 6.5 in. D Hinged Front Catalog No. Height (In.) PANELBOARDS $ Price Catalog No. $ Price $ Price NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26 MH32 NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32 MH32 NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32 NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38 MH44 NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44 MH50 NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50 NC50V ( ) 729. NC50V( )HR 912. MH50WP 2609. 50 20-inch-wide Cabinet g—Single Phase 3-Wire 18 100 30 30 42 225 72d 84d 30 400 42 1395. 2977. NQ18L1 785. 1474. 3056. NQ18L1C 864. 1585. 3149. NQ30L1 945. 1675. 3239. NQ30L1C 1035. 1744. 3308. NQ30L2 1104. 1819. 3383. NQ30L2C 1179. 2002. 3556. NQ42L2 1340. 2080. 3634. NQ42L2C 1418. 3073. 4900. NQ72L2 2297. 3206. 5033. NQ72L2C 2430. 3521 5288. NQ84L2 2679. 3677. 5444. NQ84L2C 2835. 2462. 4229. NQ30L4 1620. 2579. 4346. NQ30L4C 1737. 2620. 4387. NQ42L4 1778. 1896. 2738. 4505. NQ42L4C 84d 4853. 6534. NQ84L4C 3792. 30 2705. 4548. NQ30L6C 1863. 2861. 4704. NQ42L6C 2019. 5099. 6873. NQ84L6C 4038. 42 600 84d MH26 113. MH38 113. MH50 113. MH68 NC68V ( ) 948. NC68V( )HR 1185. MH68WP 2742. 68 MH50 NC50V ( ) 729. NC50V( )HR 912. MH62WPe 2685. 50/62 NC68V ( ) 948. NC68V( )HR 1185. MH80WPe 2835. 68/80 NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26 MH32 NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32 MH32 NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32 NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38 MH44 NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44 MH50 NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50 MH50 NC50V ( ) 729. NC50V( )HR 912. MH50WP 2609. 50 MH62 NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62 MH68 NC68V ( ) 948. NC68V( )HR 1185 MH68WP 2742. 68 NC50V ( ) 729. NC50V( )HR 912. MH62WPe 2685. 50/62 NC68V ( ) 948. NC68V( )HR 1185. MH80WPe 2835. 68/80 113. MH68 20-inch-wide Cabinet g —Three Phase 4-Wire 18 100 30 30 42 54 225 72d 84d 30 42 400 72d 1486. 3068. NQ418L1 876. 1561. 3143. NQ418L1C 951. 1752. 3316. NQ430L1 1112. 1831. 3395. NQ430L1C 1191. 1855. 3419. NQ430L2 1215. 1932. 3496. NQ430L2C 1292. 2138. 3692. NQ442L2 1476. 2213. 3767. NQ442L2C 1551. 2559. 4113. NQ454L2 1898. 2655. 4209. NQ454L2C 1994. 3307. 5134. NQ472L2 2531. 3436. 5263. NQ472L2C 2660. 3794. 5561. NQ484L2 2952. 3944. 5711. NQ484L2C 3102. 2704. 4471. NQ430L4 1862. 2822. 4589. NQ430L4C 1980. 2854. 4621. NQ442L4 2012. 2975. 4742. NQ442L4C 2133. 4449. 6134. NQ472L4 3449. 4657. 6342. NQ472L4C 3657. 84d 5327. 7008. NQ484L4C 4266. 30 2983. 4826. NQ430L6C 2141. 3116. 4959. NQ442L6C 2274. 5609. 7383. NQ484L6C 4548. 42 600 84d a b c d e f g 9-6 MH26 113. MH38 113. 113. MH50 113. MH68 “C’’ suffix indicates copper bussing. Embossed mounting holes add a 0.25-inch standoff to back of MH box. Add “F” for flush mount, “S” for surface mount. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits. When NEMA 3R, 5, or 12 enclosures are selected, an NQ12RDE kit should also be selected. See Table 9.19. Enclosure includes trim kit. For the NQ14-inch-wide panelboard offer, See Digest page 9-8. PE1A Discount Schedule © 2012 Schneider Electric All Rights Reserved NQ Merchandised Panelboards NQ Main Circuit Breaker Interiors—240 Vac, 48 Vdc Class 1640 / Refer to Catalog 1640CT0801 www.schneider-electric.us Main Circuit Breaker Interiors—Will accept plug-on and bolt-on circuit breakers Type 3R, 5, 12 Enclosure e Enclosure 20 in. W x 6.5in. D Height (In.) Catalog $ Price No. 20-inch-wide Cabinet h—Single Phase 3-Wire 16k 28k 18 1395. 100 1474. backfed 1585. 1675. 100 30 100 30 225 42 225 72d 225 84d 225 30 400 42 400 84d 400 2977. NQ18L1 785. — — 3056. NQ18L1C 864. — — MH26 113. NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26 MH32 113. NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32 MH38 113. NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38 780. MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44 780. MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44 MH50 113. NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50 MH56 113. NC56 ( ) 786. NC56( )HR 983. MH56WP 2652. 56 MH62 113. NC62 ( ) 887. NC62( )HR 1109. MH62WP 2685. 62 3149. NQ30L1 945. — — 3239. NQ30L1C 1035. — — NQMB2HJ 780. 2227. 3781. NQ18L1 785. 2306. 3860. NQ18L1C 864. 2501. 4328. NQ30L1 945. 2591. 4418. NQ30L1C 1035. 2660. 4487. NQ30L2 1104. 2735. 4562. NQ30L2C 1179. 2962. 4729. NQ42L2 3040. 4807. NQ42L2C HD, HG, HJ, HLl 100A maximum NQMB2HJ 1340. NQMB2HJ 1418. 3976. 5729. NQ72L2 2297. 4109. 5862. NQ72L2C 2430. 4459. 6144. NQ84L2 2679. 4615. 6300. NQ84L2C 2835. 3400. 5085. NQ30L4 1620. 3517. 5202. NQ30L4C 1737. 3558. 5243. NQ42L4 1778. 3676. 5361. NQ42L4C 1896. 5686. 7407. NQ84L4C Select QOB 2-pole or QOB-VHi HD, HG, HJ, HLl 780. or JD, JG, JJ, JL NQMB2Q NQMB2KI QB,QD,QG,QJ 780. KI 780. NQMB4LA 780. LA/LHm MH62 113. NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62 NQMB4LA 780. LA/LHm MH62 113. NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62 3792. NQMB4LA 780. LA/LHm MH80 113. NC80V ( ) 1001. NC80V( )HR 1245. MH80WP 2835. 80 MH26 113. NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26 MH32 113. NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32 MH38 113. NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38 MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44 MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44 MH50 113. NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50 MH56 113. NC56 ( ) 786. NC56( )HR 983. MH56WP 2652. 56 MH62 113. NC62 ( ) 887. NC62( )HR 1109. MH62WP 2685. 62 20-inch-wide Cabinet h—Three Phase 4-Wire 15k 27k 1395. 100 1474. backfed 1585. 1675. 18 100 30 30 42 54 225 72d 84d 30 42 72d 84d a b c d e f g h i j k l m 400 2977. NQ418L1 785. — — 3056. NQ418L1C 864. — — 3149. NQ430L1 945. — — 3239. NQ430L1C 1035. — — 2318. 3872. NQ418L1 876. 2393. 3947. NQ418L1C 951. 2668. 4495. NQ430L1 1112. 2747. 4574. NQ430L1C 1191. 2771. 4598. NQ430L2 1215. 2848. 4675. NQ430L2C 1292. 3098. 4865. NQ442L2 1476. 3173. 4940. NQ442L2C 1551. 3519. 5286. NQ454L2 1898. 3615. 5382. NQ454L2C 1994. 4210. 5963. NQ472L2 4339. 6092. NQ472L2C 4732. 6417. NQ484L2 2952. 4882. 6567. NQ484L2C 3102. 3642. 5327. NQ430L4 1862. 3760. 5445. NQ430L4C 1980. 3792. 5477. NQ442L4 2012. 3913. 5598. NQ442L4C 2133. 5314. 6986. NQ472L4 3449. 5522. 7194. NQ472L4C 3657. 6160. 7881. NQ484L4C NQMB2HJ Select QOB 3-pole or QOB-VHj HD, HG, HJ, HL 780. 100A maximum 780. NQMB2HJ 780. NQMB2Q 2531. NQMB2KI 2660. HD, HG, HJ, HL or JD, JG, JJ, JL QB,QD,QG,QJ 780. KI 780. NQMB4LA 780. LA/LHm MH62 113. NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62 NQMB4LA 780. LA/LHm MH74 113. NC74V ( ) 972. NC74V( )HR 1215. MH74WP 2757. 74 4266. NQMB4LA 780. LA/LHm MH80 113. NC80V ( ) 1001. NC80V( )HR 1245. MH80WP 2835. 80 “C’’ suffix indicates copper bussing. Embossed mounting holes add a 0.25 inch standoff to back of MH box. Add “F” for flush mount, “S” for surface mount. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits. Enclosure includes trim kit. Select the appropriate main circuit breaker from the tables starting on Digest page 7-22 and add the circuit breaker price to the total price of the panelboard. Circuit breaker interrupt ratings, See the tables starting on Digest page 7-22. For the NQ14-inch-wide panelboard offer, See Digest page 9-8. QOB2150VH takes four pole spaces; all other QOB two pole circuit breakers take two pole spaces. QOB3110VH to QOB3150VH take six pole spaces; all other QOB three pole circuit breakers take three pole spaces. Pole spaces shown are available for branch circuits, with spaces deducted for the back fed main breaker. For single phase applications, order a 3-pole breaker. Example: HDL36100. For 400A applications, order short handle circuit breaker (LAL36400MB). © 2012 Schneider Electric All Rights Reserved PANELBOARDS Total $ Price Type 1 Enclosure Interior Only Interior, Front, (Order Circuit Breaker Adapter Kit Branch Circuit Main(Less Box and Circuit Breaker) f Box Pole Mains Breakers Separately) Hinged Front 20 in. W x 5.75 in. D b Mono-Flat™ Front Spaces Rating Adapter Kit f 3R, Circuit Breaker Catalog Type 1 Type $ Price Catalog No. $ Price 5, 12 Catalog No. a $ Price Catalog No. $ Price Frame Size g Catalog No. $ Price No. c PE1A Discount Schedule 9-7 9 Table 9.10: NQ Merchandised Panelboards NQ 14-inch-wide Panelboards Class 1640 www.schneider-electric.us 9 NQ 14-inch-wide—240 Vac, 48 Vdc 14-inch-wide NQ panelboards are now available for those customers whose equipment space is limited. Developed with customer input, Square D™ brand NQ panelboards are built to last, featuring innovations for ease of installation and durability. Features PANELBOARDS • • • • • • • 240 Vac, 48 Vdc maximum 225 A maximum main circuit breaker or main lugs 60 A maximum branch circuit breakers Visi-Trip™ indication on branch circuit breakers 10,000–65,000 A Short Circuit Current Rating (SCCR) Interiors supplied with tin plated copper bus as standard Interiors accept bolt-on and plug-on branch circuit breakers Table 9.11: 14-inch-wide NQ Panelboard Main Lug • Three-phase, four-wire, and single-phase, three-wire interiors available Panelboards available with Mono-Flat™ front Suitable for use as service entrance equipment Branch circuit filler plates provide fast and easy installation Both fully and series-rated systems are available • • • • Main Lug Interiors—Accepts Plug-On and Bolt-On Branch Breakers Max. Number of Breakers Main Ratings Total $ Price Interior, Front, Box and Adapter Kit Type 1 Interior Only (Order Branch Circuit Breakers Seperately) Type 3R, 5, 12 Cat. No. $ Price Type 1 Enclosure Box 14"W x 5.75" Db Cat. No. $ Price Mono Flat Front Cat. No. b $ Price Hinged Front Cat. No. $ Price 14-inch-wide Cabinet—Single Phase 3-Wire 18 100 A 30 30 225 A 42 1407. — NQ18L1C14 951. NQB532 118. NQC32 338. N/A — 1647. — NQ30L1C14 1191. NQB532 118. NQC32 338. N/A — 1748. — NQ30L2C14 1292. NQB532 118. NQC32 338. N/A — 2028. — NQ42L2C14 1151. NQB538 118. NQC38 338. N/A — 14-inch-wide Cabinet—Three Phase 4-Wire 18 100 A 30 30 225 A 42 Table 9.12: 1407. — NQ418L1C14 951. NQB532 118. NQC32 338. N/A — 1647. — NQ430L1C14 1191. NQB532 118. NQC32 338. N/A — 1748. — NQ430L2C14 1292. NQB532 118. NQC32 338. N/A — 2028. — NQ442L2C14 1151. NQB538 118. NQC38 338. N/A — Main Circuit Breaker Interiors—Accepts Plug-On and Bolt-On Branch Breakers Max. Number Main of Ratings Breakers Total $ Price Interior, Front, Box and Adapter Kit Type 1 Interior Only (Order Main Circuit Breaker Adapter Kit Branch Circuit (Less Circuit Breaker) Box 14"W x 5.75" Breakers Seperately) Db Type 3R, 5, 12 Cat. No. $ Cat. No.c Price Type 1 Enclosure Mono Flat Front Hinged Front $ Price Cat. No $ Price Cat. No Select QOB 2-pole or QOB-VH NQB532 118. NQC32 338. N/A — NQB532 118. NQC32 338. N/A — HD, HG, HJ, HL, OR JD, JG, JJ, JL, QB , QD, QG, QJ NQB544 118. NQC44 338. N/A — NQB550 118. NQC50 359. N/A — Select QOB 3-pole or QOB-VH NQB532 118. NQC32 338. N/A — NQB532 118. NQC32 338. N/A — HD, HG, HJ, HL, OR JD, JG, JJ, JL, QB , QD, QG, QJ NQB544 118. NQC44 338. N/A — NQB550 118. NQC50 359. N/A — Cat. No. b $ $ Price Cat. No. Price 14-inch-wide Cabinet—Single Phase 3-Wire 16 a 100 28 a Main Breaker Panelboard 30 225 42 1407. — NQ18L1C14 951. — — 1647. — NQ30L1C14 1191. — — 1748. — NQ30L2C14 1292. 2028. — NQ42L2C14 780. 1151. NQMB2HJ14 or NQMB2Q14 78. 14-inch-wide Cabinet—Three Phase 4-Wire 15 a 100 27 a 30 225 42 a b c 1407. — NQ418L1C14 951. — — 1647. — NQ430L1C14 1191. — — 1748. — NQ430L2C14 1292. 2028. — NQ442L2C14 1151. 780. NQMB2HJ14 or NQMB2Q14 78. Pole spaces shown are available for branch circuits, with spaces deducted for the back-fed main breaker. Add “F” for flush mount, “S” for surface mount. All 14” W boxes come with blank endwalls. Table 9.13: NQ Accessories Description Catalog No. $ Price Schedule Equipment Ground Bars Main Lug Panelboard Aluminum PK27GTA 33.80 PK23GTA+ #1 to #4/0 Al or Cu lug PK23GTAL 40.70 PK27GTACU 84.00 PE-1A Copper Ground Bar Insulator Kit Filler plate (15 per package) DE3A PKGTAB 43.80 DE3A NQFP15d 68.00 PE1A HLO1 9.90 Handle Attachments—Branch Circuit Breakers Handle lock-off Handle tie - (QO and QOB only) QO1HT 3.80 Handle padlock attachment—1-pole QO1PA 10.70 2- and 3-pole QO1PL 10.70 Handle tie and lock-off for three 1-pole (QO, QOB) QO3HT 13.40 d 9-8 DE2A Filler Plates are $3.00 each and must be ordered in packages of 15. PE1A Discount Schedule © 2012 Schneider Electric All Rights Reserved NQ Merchandised Panelboards NQ Merchandised Accessories Class 1640 / Refer to Catalog 1640CT0801 www.schneider-electric.us NQ Merchandised Neutrals 200% Neutral Kit Mains Ampacity Catalog No. NQNL1 NQNL2 or NQNL2ACCYb NQNL4a 100 225 400 600 a b Copper 100% Neutral Kit $ Price 315. 426. 639. Box Add Schedule no adder PE-1A no adder PE-1A Catalog No. NQN1CU NQN2CU NQN6CU NQN6CUa Not Available $ Price Box Add Schedule 192. no adder PE-1A 585. no adder PE-1A PANELBOARDS Table 9.14: Not to be used with SFL, FTL, or SFB. These combinations are factory assembled only. For 225A panel with SFL, FTL, or SFB, use NQNL2ACCY (enclosure size increases by 6 inches). Otherwise, use NQNL2. NQ Merchandised Sub-feed Lugs, Feed-through Lugs and Sub-feed Breakers Sub-feed Lugs (N/A in MCB Interiors) Mains Ampacity 100 A Catalog No. NQSFL1 225 A NQSFL2 400 A $ Price 155. 203. NQSFL4 600 A 260. Schedule PE-1A PE-1A PE-1A Sub-feed Circuit Breaker Kits (breaker not incl.) Feed-through Lugs Catalog No. 100 A not available; NQFTL2Lc NQFTL2Hd NQFTL4Lc NQFTL4Hd $ Price — Single SFB Schedule — 476. 507. Catalog No. — NQSFB2Q or NQSFB2HJ PE-1A PE-1A $ Price Two SFB Schedule — — 1029. Use the 2 SFB kit Use FTL Catalog No. — $ Price — Schedule — PE-1A — — — — NQSFB4Q or NQSFB4HJ 1290. PE-1A Factory Assembled Only 9 Table 9.15: Note: See Table 9.16 and Table 9.17 for box selection table. c The final character L indicates the kit is used for Low circuit count interiors 30 and 42. d The final character H indicates the kit is used for High circuit count interiors 54, 72, and 84. e MH26 — — Use FTL MH32 MH38 MH50 Use FTL — MH44 MH50 Use FTL — MH50 MH62 Use FTL — MH56 MH68 Use FTL Sub-feed Circuit Breakers 400 A 600 A (two) (two) — MH74 MH74 MH86 e 100 A 18 30 42 72 84 — — — — — AL Compression Lug Kit 400 A — — MH62 MH68 MH80 MH80 MH50 MH62 MH68 Sub-feed Circuit Breakers 600 A 100 A — — — — — CU Mechanical Lug Kit 100 225 Catalog No. NQALV1 NQALV2 Lug Wire Range one #8–1/0 AWG one #4–300 kcmil $ Price 117.00 33.00 Catalog No. NQCUM1 NQCUM2 400 NQALV4 two 2/0–500 kcmil 663.00 NQCUM4 600 NQALV6 two 2/0–500 kcmil 1208.00 NQCUM6 Lug Wire Range one #6–2/0 AWG one #6–250 kcmil one 1/0–750 kcmil two 1/0–350 kcmil one 1/0–750 kcmil two 1/0–350 kcmil 225 A (one) — MH62 MH68 MH74 MH80 400 A (two) — MH86 MH86 f f 600 A (two) CU Compression Kit $ Price Catalog No. NQCUV1 NCQUV2 Lug Wire Range one #6–1/0 AWG one 2/0–300 kcmil 636.00 NQCUV4 one 400–700 kcmil 767.00 1139.00 NQCUV6 two 250–500 kcmil 1364.00 347.00 $ Price 345.00 417.00 NQ Accessories Description Catalog No. Sub-feed (Bolt-on) 2-pole 3-pole Equipment Ground Bars Aluminum PK23GTA+ #1 to #4/0 Al or Cu lug Copper Ground Bar Insulator Kit Filler plate (15 per package) Circuit I.D. Number Strips 1–102 odd/even (left side numbered 1,3,5 ...101) 103–204 odd/even (left side numbered 103,105,107 ... 203) 1–102 sequential (left side numbered 1,2,3 ... 102) 103–204 sequential (left side numbered 103,104,105 ... 204) 6 in. Extension 12 in. Extension Rail and Deadfront Extensions 18 in. Extension 24 in. Extension Touch-up paint USAS #49 Gray (Aerosol can) Handle Attachments—Branch Circuit Breakers Handle lock-off Handle tie - (QO and QOB only) Handle padlock attachment—1-pole 2- and 3-pole Handle tie and lock-off for three 1-pole (QO, QOB) Handle tie for two 10–30 A single pole QO(B) circuit breaker Handle tie for three 10–30 A single pole QO(B) circuit breaker Handle Padlock Attachment for Padlocking in OFF position For padlocking 1P QO circuit breaker in OFF position only, fixed attachment For padlocking 2P and 3P QO circuit breaker in OFF position only, fixed attachment For padlocking 1P QO-GFI, QO-AFI, QO-CAFI, and QO-EPD circuit breakers in OFF position only, fixed attachment For padlocking 2P QO-GFI and QO-EPD circuit breakers in OFF position only, fixed attachment Neutral or Ground Lugs #10 to #2 Al or #14 to #4 Cu #4 to #1/0 Al or Cu #1 to #4/0 Al or Cu Endwalls for MH Enclosures Blank (one per package) With Knockouts (one per package) g 225 A NQ Optional Lugs Ampacity Table 9.19: Feed-through Lugs Feature Circuits f (c) Requires box longer than available box offer. NOTE: NQ SurgeLogic SurgeLoc Plug-on SPD appears on page 9-44. (c) Requires box longer than available box offer. Table 9.18: Box Selection Table: Merchandised NQ Vertically Mounted Main Breaker Panelboards w/ Accessories Factory Asssembled Only 18 30 42 72 84 Feed-through Lugs A 100 A 225 A 400 A 600 A 100 A 225 (one) — — — — — MH38 MH50 — MH50 Use MH38 MH56 — MH56 225A — MH62 Interior MH50 MH68 MH56 MH68 — MH68 Factory Asssembled Only Sub-feed Lugs Feature Circuits 100 A 225 A 400 A 600 A Table 9.17: Factory Asssembled Only Box Selection Table: Merchandised NQ Main Lug Panelboards with Accessories Factory Asssembled Only Table 9.16: $ Price Schedule QOB2125SL QOB3125SL 176.00 176.00 PK27GTA PK23GTAL PK27GTACU PKGTAB NQFP15g 33.80 40.70 84.00 43.80 68.00 NQ102OE NQ204OE NQ102S NQ204S NQ6RDE NQ12RDE NQ18RDE NQ24RDE PK49SP 7.90 7.90 7.90 7.90 252.00 283.00 343.00 397.00 39.00 HLO1 QO1HT QO1PA QO1PL QO3HT QOHT2 QOHT3 9.90 3.80 10.70 10.70 13.40 10.90 12.80 QO1PAF QO2PAF QOGFI1PAF QOGFI2PAF 43.50 25.80 51.00 38.40 DE2E QO70AN Q1100AN Q1150AN 9.90 11.10 32.40 DE3A 8011010501 8011010401 41.10 41.10 PE1A DE2A DE3A PE-1A DE3A PE1A PE1A DE1 DE2A DE2 Filler Plates are $4.50 each and must be ordered in packages of 15. © 2012 Schneider Electric All Rights Reserved PE1A DE2A DE2E DE3A Discount Schedule 9-9 QOB Bolt-On Circuit Breakers With Visi-Trip™ Indicator for NQ Panelboards l Class 690, 730, 910, 950 www.schneider-electric.us QOB-GFI, QOB-EPD, and QOB-EPE Circuit Breakers Table 9.21: Two-pole— Three-pole—Common Trip Common Trip $ Catalog No. $ $ $ Catalog No. Price Catalog No. Price Catalog No. Price Price QOB-GFI—QOB Qwik-Gard™ Circuit Breaker With Ground Fault Circuit Interrupter— UL Class A 4–6 mA People Protection. b 120/240 Vac— 208Y/120 Vac— 120 Vac—10 k AIR 10 k AIR 10 k AIR 15 A QOB115GFI 248. QOB215GFI 444. QOB315GFI 791. 20 A QOB120GFI 248. QOB220GFI 444. QOB320GFI 791. 25 A QOB125GFI 248. QOB225GFI 444. — — 30 A QOB130GFI 248. QOB230GFI 444. QOB330GFI 791. 40 A — — QOB240GFI 444. QOB340GFI 791. 50 A — — QOB250GFI 444. QOB350GFI 791. 60 A — — QOB260GFI c 444. — — QOB-VHGFI d 120 Vac—22 k AIR 15 A QOB115VHGFI 497. 20 A QOB120VHGFI 497. 25 A QOB125VHGFI 497. 30 A QOB130VHGFI 497. QOB-EPD—QOB Equipment protection circuit breakers with UL Listed 30 mA (EPD) or 100 mA (EPE) equipment protection. 120/240 Vac— 120 Vac—10 k AIR 240 Vac—10 k AIR 10 k AIR 15 A QOB115EPD 417. QOB215EPD 671. QOB315EPDm1077. QOB315EPEm1077. 20 A QOB120EPD 417. QOB220EPD 671. QOB320EPDm1077. QOB320EPE 1077. 25 A QOB125EPD 417. QOB225EPD 671. — — — — 30 A QOB130EPD 417. QOB230EPD 671. QOB330EPDm1077. QOB330EPEm1077. 40 A — — QOB240EPD 671. QOB340EPDm1077. QOB340EPEm1077. 50 A — — QOB250EPD 671. QOB350EPDm1077. QOB350EPEm1077. 60 A — — QOB260EPD 671. — — — — QOB-VHEPD 120 Vac—22 k AIR 15 A QOB115VHEPD 772. 20 A QOB120VHEPD 772. 25 A QOB125VHEPD 772. 30 A QOB130VHEPD 772. QOB-HM—High magnetic trip circuit breakers 15 A QOB115HMe 39.80 20 A QOB120HMe QOB-K—Key operated QOB circuit breakers f 120 Vac—10 k AIR 10 A QOB110K 168. 15 A QOB115K 168. 20 A QOB120K 168. 25 A QOB125K 168. 30 A QOB130K 168. (Footnotes for Tables 9.20, 9.21, and 9.22) a 10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors. 35–60 A circuit breakers are suitable for use with 75 °C conductors. b Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. c Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. d Recommended for applications where high initial inrush may occur and for individual dimmer applications. e UL Listed as SWD (switching duty) rated suitable for switching 120 Vac fluorescent lighting loads. f Available in single pole construction and can be mounted in any single pole space which will accept a standard QOB. These circuit breakers can be turned ON or OFF or RESET with a special key (Catalog No. QOK10) included with the circuit breaker. These circuit breakers are UL Listed and available as shown in the table. g UL Listed for use on circuit feeding fluorescent and High Intensity Discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QOB circuit breakers. h UL Listed 5,000 AIR on 3Ø corner grounded delta systems. i UL Listed as HACR type for use with air conditioning, heating, and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. j DC Rating is not available on indicated products. k QOB2150VH uses 4 pole spaces. QOB3110VH, QOB3125VH, and QOB3150VH each use 6 pole spaces. 40A maximum circuit breaker mounted opposite. Use with 75 °C wire only. l For QO plug-on circuit breaker pricing, see the tables starting on Digest page 1–2. m See note in Instruction Bulletin when using in an enclosure with a QO403 or QON prefix. Ampere Rating a 9 Table 9.20: One-pole PANELBOARDS Table 9.23: QO/QOB Circuit Breaker Wire Sizes Breaker Type Ampere Rating n Two-pole—Common Trip One-pole Two-pole— Common Trip h Three-pole— Common Trip Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price QOB Bolt-On 120 Vac—10 k AIR 48 Vdc—5 k AIR 10 A QOB110 39.80 15 A QOB115 ie 39.80 20 A QOB120 ie 39.80 25 A QOB125 i 39.80 30 A QOB130 i 39.80 35 A QOB135 i 39.80 40 A QOB140 i 39.80 45 A QOB145 i 39.80 50 A QOB150 i 39.80 60 A QOB160 i 39.80 70 A QOB170 i 78. 80 A — — 90 A — — 100 A — — 110 A — — 125 A — — Molded Case Switch 60 A max— 240 Vac Molded Case Switch 100 A max— 240 Vac Table 9.22: Ampere Rating a 120/240 Vac—10 k AIR 240 Vac— 48 Vdc—5 k AIR j 10 k AIR QOB210 89. — QOB215 i 89. QOB215H QOB220 i 89. QOB220H QOB225 i 89. QOB225H QOB230 i 89. QOB230H QOB235 i 89. — QOB240 i 89. QOB240H QOB245 i 89. — QOB250i 89. QOB250H QOB260 i 89. QOB260H QOB270 i 168. QOB270H QOB280 ij 240. QOB280H QOB290 ij 240. QOB290H QOB2100 ij 240. QOB2100H QOB2110 ij 501. — QOB2125 ij 501. — — 240. 240. 240. 240. — 240. — 240. 240. 308. 366. 366. 366. — — 240 Vac—10 k AIR 48 Vdc—5 k AIR j QOB310 293. QOB315 i 293. QOB320 i 293. QOB325 i 293. QOB330 i 293. QOB335 i 293. QOB340 i 293. QOB345 i 293. QOB350 i 293. QOB360 i 293. QOB370 ij 369. QOB380 ij 419. QOB390 ij 419. QOB3100 ij 419. — — — — QOB200 89. — — QOB300 293. QOB2000 234. — — QOB3000 507. High Interrupting QOB and Specialty Circuit Breakers One-pole Catalog No. Two-pole—Common Trip $ Price Catalog No. $ Price Three-pole—Common Trip Catalog No. $ Price QOB-VH 120 Vac—22 k AIR QOB115VHie 72. QOB120VHie 72. QOB125VHi 72. QOB130VHi 72. QOB140VH 86. QOB150VH 86. QOB160VH 86. QOB170VH 137. — — — — — — — — — — — — 120/240 Vac —22 k AIR QOB215VHi 171. QOB220VHi 171. QOB225VHi 171. QOB230VHi 171. QOB240VHi 171. QOB250VHi 171. QOB260VHi 171. QOB270VHi 273. QOB280VHi 384. QOB290VHi 384. QOB2100VHi 384. QOB2110VHi 1110. QOB2125VHi 1110. QOB2150VH k 1223. 240 Vac—22 k AIR QOB315VHi 440. QOB320VHi 440. QOB325VHi 440. QOB330VHi 440. QOB340VHi 440. QOB350VHi 440. QOB360VHi 440. QOB370VHi 560. QOB380VHi 629. QOB390VHi 629. QOB3100VHi 629. QOB3110VH k 1809. QOB3125VH k 1809. QOB3150VH k 1809. 120 Vac—65 k AIR 15 A QHB115i e 122. 20 A QHB120i e 122. 25 A QHB125i 122. 30 A QHB130i 122. QOB-HID—HID circuit breakers g 120 Vac/240 Vac—65 k AIR QHB215i 342. QHB220i 342. QHB225i 342. QHB230i 342. 240 Vac—65 k AIR QHB315i 596. QHB320i 596. QHB325i 596. QHB330i 596. 120 Vac—10 k AIR 120/240 Vac—10 k AIR 15 A QOB115HIDe 49.50 QOB215HID 108. 20 A QOB120HID e 49.50 QOB220HID 108. 25 A QOB125HID 49.50 QOB225HID 108. 30 A QOB130HID 49.50 QOB230HID 108. 40 A QOB140HID 49.50 QOB240HID 108. 50 A QOB150HID 49.50 QOB250HID 108. QOB-SWN—Switch Neutral—Common Trip—NEC 514.11 240 Vac—10 k AIR QOB315HID 327. QOB320HID 327. QOB325HID 327. QOB330HID 327. — — — — 1-pole—2-Wire 2 Spaces —120 Vac QOB210SWN 116. QOB215SWN 116. QOB220SWN 116. QOB225SWN 116. QOB230SWN 116. QOB240SWN 116. QOB250SWN 116. 2-pole—3-Wire 3 Spaces—120/240 Vac QOB310SWN 170. QOB315SWN 170. QOB320SWN 170. QOB325SWN 170. QOB330SWN 170. QOB340SWN 170. QOB350SWN 170. 15 A 20 A 25 A 30 A 40 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A QHB 10 A 15 A 20 A 25 A 30 A 40 A 50 A Table 9.24: — — — — — — — — — — — — — — QO™ Arc-Fault Circuit Breakers o p Wire Size (AWG) Al Cu 10–30 A #14–8 #14–8 QOB 10–30 A — two #14–10 1-pole 35–70 A #8–2 #8–2 10–30 A #14–8 #14–8 10–30 A — two #14–10 QOB 35–70 A #8–2 #8–2 2-pole 80–125 A #4–2/0 #4–2/0 150–200 A #4–300 kcmil #4–300 kcmil 10–30 A #14–8 #14–8 QOB 35–70 A #8–2 #8–2 3-pole 80–125 A #4–2/0 #4–2/0 QOB-VH 110–150 A #4–300 kcmil #4–300 kcmil 15–30 A #12–8 #14–8 QOB-GFI and QOB-EPD 40, 50, or 60 A #12–4 #14–6 n 10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors. 35–60 A circuit breakers are suitable for use with 75 °C conductors. 9-10 Ampere Rating a Standard Interrupting QOB 10,000 AIR Circuit Breakers Circuit Breaker Type Ampere Rating q 1P 120 Vac 10 kAIR 1 Space Required 1P 120 Vac 22 kAIR 1 Space Required Catalog Number $ Price Catalog Number $ Price Combination 15 A QOB115CAFI 306. QOB115VHCAFI 612. Arc-Fault 20 A QOB120CAFI 306. QOB120VHCAFI 612. Interupter Note: See Digest page 7-12 for accessories. o UL Listed as HACR type for use with air conditioning, heating, and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. p QO arc-fault circuit breakers provide branch feeder protection (for example, QO115AFI) or combination protection (for example, QO115CAFI) as required by the NEC and local code adoption, and comply with UL 1699. q 10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors. 35–60 A circuit breakers are suitable for use with 75 °C conductors. DE2A Discount Schedule © 2012 Schneider Electric All Rights Reserved NQ Factory Assembled Panelboards 240 Vac, 48 Vdc Class 1640 / Refer to Catalog 1640CT0801 www.schneider-electric.us Base Price (With Solid Neutral) Main Circuit Breaker (Circuit Breaker Interrupt Rating—pages 6-2 through 6-8) a Main Lugs Mains Rating 60 A 100 A 150 Ac 225 Ac 250 Ac 400 Ac 600 Abc $ Price 2-pole — 720. 720. 720. — 3-pole — 832. 832. 832. — 772. 928. — 1422. 2082. — 1634. 2326. Circuit Breaker HIC QOB 2-pole 1192. 3-pole 1464. QOB 1254. HD HD QB JD QD JD LA — 2030. 3180. 2450. 3980. 3084. 4390. 5366. — Extra HIC $ Price Circuit Breaker QOB-VH 2-pole 1258. 3-pole 1586. 1562. QOB-VH 1382. 1712. 2380. 3530. 2800. 4300. 3434. 4640. 6106. — HG HG 2700. 3840. 3050. 4190. QG JG 3740. 4510. 4090. 5100. JG LH — 5040. 7708. — 6020. 8834. — Circuit Breaker I-Limiter™ $ Price HJa 2-pole 2950. 2950. 2950. 2950. 4000. 3-pole 3300. 3300. 3300. 3300. 4350. QJ JJa 3970. 6450. JJa LJ LJ 7100. 10624. 12930. HJa HJa $ Price Circuit Breaker FI FI FI FI — 2-pole 4088. 4088. 4088. 4088. — 3-pole 4858. 4858. 4858. 4858. — 4320. 7280. KI 7436. 8680. 8020. 10624. 12930. KI LR LR 8264. 13552. 16002. 9672. 13552. 16002. Equipment Ground Bar—38. QL, HJ, HL, JJ, and JL circuit breakers are also available. Copper bus standard Prices are for 54-circuit and fewer interiors. See the Product Selector for 72- and 84-circuit interior pricing. Table 9.26: Branch Circuit Breakers 9 Note: a b c Standard IC Table 9.27: Specialty Branch Circuit Breakers Plug-On or Bolt-On Circuit Breaker Ampere Rating Plug-On or Bolt-On $ Price 1-pole 2-pole 120 Vac 120/240 Vac 2-pole 240 Vac 3-pole 240 Vac 3-pole 208Y/120 Vac Space Only All Space Only 28. 58. 58. 86. — except below QOB–VH, Space — 116. — 174. — Only (125–150 A) 10,000 AIR—Branch Circuit Breakers—QO™, QOB, QO-H, QOB-H 15–60 A 68. 134. 260. d 352. — 70 A 100. 208. 296. d 396. — 80–100 A — 262. 380. d 458. — 110–125 A — 482. — — — 10,000 AIR—Combination Arc Fault Circuit Interrupters—QO-CAFI, QOB-CAFI 15–20 A 470. — — — — 10,000 AIR—Qwik–Gard™—Class A—QO-GFI, QOB-GFI Provided with a 5 mA setting on ground fault sensor 15–30 A 272. 488. — — 920. 40–50 A — 488. — — 920. 60 A — 488. — — — 10,000 AIR—Qwik–Gard—Class A—QO-EPD, QOB-EPD Provided with a 30 mA setting on ground fault sensor 15–30 A 462. 828. — 1210. — 40–50 A — 828. — 1210. — 60 A — 828. — — — 10,000 AIR—Qwik–Gard—Class A—QO-EPE, QOB-EPE Provided with a 100 mA setting on ground fault sensor 15–30 A — — — 1210. — 40–50 A — — — 1210. (High Interrupting Capacity) 22,000 AIR Branch Circuit Breakers—QO-VH, QOB-VH 15–30 A 92. 212. — 462. — 35–60 A — 212. — 462. — 70 A — 292. — 556. — 80–100 A — 378. — 606. — 110–125 A — 1022. — — 1746.e 150 A — 1140. e — — 22,000 AIR—Combination Arc Fault Circuit Interrupters—QO-VHCAFI, QOB-VHCAFI 15–20 A 680. — — — — 22,000 AIR—Qwik-Gard—Class A—QO-VHGFI, QOB-VHGFI 15–30 A 575. — — — 42,000 AIR Branch Circuit Breakers—QOH 35–60 A — 368. f — — 70 A — 596. f — — 80–100 A — 688. f — — 110–125 A — 1402. f — — 65,000 AIR Branch Circuit Breakers—QH, QHB 15–30 A 144. 348. — 596. Circuit Breaker Ampere Rating $ Price 1-pole 120 Vac 2-pole 120/240 Vac 2-pole 240 Vac 3-pole 240 Vac Specialty Branch Circuit Breakers (10,000 AIR) For High Intensity Discharge Lighting—QO-HID, QOB-HID 15–30 A 78. 148. — 376. 40–50 A 78. 148. — — Switch Neutral—QO-SWN, QOB-SWN 1-pole 2-pole — 2-wire — 3-wire 15–50 A (2 spaces) (3 spaces) — 154. — 220. High Magnetic Trip (For applications subject to high initial inrush)— QO-HM, QOB-HM 15–20 A 68. — — — Sub-feed Circuit Breakers Main lugs or main circuit breaker interior—1Ø or 3Ø. Maximum 1 circuit breaker per 225 A main lug or 250 A main circuit breaker panelboard, 2 circuit breakers per 400–600 A panelboard. Table 9.28: Sub-feed Circuit Breaker (110–225 A) (SeeTable 9.29 for correct box size.) No. of Poles 2 3 Space g Ampacity QD QG 1762. 2296. 826. 3812. 4608. 826. HD 2456. 2872. 826. HG JD 3500. 3798. 826. JG 3020. 3370. 826. 4220. 5100. 826. QJ, HJ, HL, JJ, and JL circuit breakers are also available. Sub-feed Circuit Breaker Cabinet Data Max. No. of Branch Spaces (Does not include sub-feed circuit breaker spaces) 30 42 54 72 84 h QB 110–225 A 1218. 110–225 A 1848. 110–225 A 826. Table 9.29: — — — — — Box Height (20 in. W x 5.75 in. D) 225 A 250 A Main Lug Main Circuit Breaker 62 68 68 74 80 50 56 56 62 68 400 A Main Lug 74 74 80 86 — Main Circuit Breaker 86 86 — — — 600 A Main Lug Main Circuit Breaker 74 80 80 86 — Not available with MCB Not Available in Type 3R, 5, 12 if subfeed breaker is over 150 A. — Note: Shunt Trip, Auxiliary Switch, and Alarm Switch—accessories for circuit breakers—add $ Price from page 7-12. d UL Listed for use on 3Ø, grounded BØ systems, (5,000 AIR for this application). e Bolt-on only; 2-pole requires 4 vertical spaces, 3-pole requires 6 vertical spaces. f Plug-on only. © 2012 Schneider Electric All Rights Reserved PE1 Discount Schedule PANELBOARDS Table 9.25: 9-11 NQ Factory Assembled Panelboards Common Features Class 1640 / Refer to Catalog 1640CT0801 www.schneider-electric.us 9 Sub-feed Lugs Table 9.39: NOTE: Available on main lug interiors only, 1Ø or 3Ø. Table 9.30: Panelboard Ampacity Sub-feed Wire Range Per Phase PANELBOARDS Mains Rating Incoming Outgoing Price per Panel 100 225 400 one #6-2/0 Al or Cu one 1/0-350 kcmil Al or Cu one 1/0-750 kcmil Cu only one #6-2/0 Al or Cu one 1/0-350 kcmil Al or Cu one 1/0-750 kcmil Cu only $128. $128. $164. Table 9.31: Sub-feed Lug Cabinet Data 100 A 225 A 400 A 18 30 42 54 72 84 MH26 MH32 — — — — — MH38 MH44 MH44 MH50 MH56 — MH50 MH50 MH50 MH62 MH68 Table 9.41: 100 A 225 A 400 A 600 A one #6-2/0 Al or Cu one #6–350 kcmil Al or Cu one 1/0–750 kcmil or two 1/0–350 kcmil Al or Cu two 1/0–750 kcmil Al or Cu $ Price 344. 344. 826. 826. a 38 38 50 56 50 50 62 68 50 56 68 68 62 62 74 80 68 80 — — $ Price Adder 38. 52. 86. $ Price Adder Standard white face/black letter laminated bakelite, 1 in. x 3.5 in., adhesive backed or screw mountable with screws in a bag assembly (price includes engraving) Table 9.45: 78. 128. 388. Standard 80 kA 100 kA 120 kA 160 kA 200 kA 240 kA 148. 168. 168. Price Per Pole Adder H Frame J Frame LA Frame LC Frame 58. 70. 70. 98. 108. 108. 148. 148. 148. 148. 168. 168. b Voltage 120 / 240 V 208 Y / 120 V 6170. 6540. 7370. 8430. 9720. 10840. 240 / 120 HLD 6540. 7370. 7870. 8620. 9770. 12370. 6540. 7370. 7870. 8620. 9770. 12370. SurgeLogic units occupy 12 circuit positions (6 adjacent mounting spaces per side.) 132. 200% Rated Neutrals one #6-2/0 kcmil Al or Cu per lug one #6-350 kcmil Al or Cu per lug one #1/0-750 kcmil Al or Cu per lug or two 1/0-300 kcmil per lug Surgelogic SPD Options Description Panelboards with 200% rated neutrals are not available Add Per Panel with 250 A J- and K-frame main circuit breakers or $ Price integral lighting contactors 9-12 600A 148. 148. 148. Surgelogic™ SurgeLoc Plug-On SPD b Surge Current Rating kA Table 9.46: $ Price Adder 100–600 A a 400A Copper Neutrals Copper Neutrals 400 Aa 58. 108. 108. Optional Factory Assembled Lugs for Main Circuit Breaker Interiors Aluminum Compression Lugs Copper Mechanical Lugs Copper Compression Lugs $ Price Adder Copper Bus Bars 100 Aa 225 Aa 225A 58. 70. 70. Main Circuit Breaker Interiors: Copper Bus Bars 100 A, 225 A, 250 A 400 A 600 A Table 9.38: Price Per Pole Adder 100A Note: Optional lugs are not available for Q frame main or QOB circuit breakers Name Plates Name Plates Table 9.37: 1516. Optional Factory Assembled Lugs for Main Lug Interiors Main Lug Interiors: Table 9.44: Equipment Ground Bar Copper Ground Bar (add to Equipment Ground Bar price) Insulated/Isolated Ground Bar (add to Equipment Ground Bar price) Table 9.36: $ Price Adder Ground Bars Ground Bars Table 9.35: Weatherproof or Dusttight Cabinets—Type 3R, 5, 12 Aluminum Compression Lugs Copper Mechanical Lugs Copper Compression Lugs 8.75 in. deep box, ship fully assembled only. Table 9.34: 836. 400 and 600 A NQ panelboards with sub-feed circuit breakers are not available with a weatherproof enclosure (Use I-Line). 600 A 62 68 80 80 646. Note: 600 A L-Frame main circuit breaker NQ panelboards are not available with a weatherproof enclosure (Use I-Line) Table 9.43: 400 A Main Main Main Main Lugs Circuit Main Lugs Circuit Main Lugs Circuit Breaker Breaker Breaker a 30 42 72 84 Add Per Panel $ Price 400 A NQ panelboards are available with a subfeed breaker up to 150 A. See Table 9.29 on page 9-11. Box Height (20 in. W x 5.75 in. D) 250 A Hinged Door-in-Door Trims Weatherproof or Dusttight Cabinets Feed-through Lug Cabinet Data 225 A 140. Hinged Door-in-Door Trim has piano hinge down one side. Inner door has a lock, outer door is retained with screws Hinged Door-in-Door with Outer Door Lock in place of screws ó Max. No. of Branch Spaces $ Price Adder Hinged Door-in-Door Trim Table 9.42: Feed-Through Wire Range Per Phase Metal Directory Frames Replaces standard plastic stick-on directory pouch Feed-through Lugs Table 9.33: (2) 1/0 Cu or Al (2) #4-300kcmil (2) 4/0 Cu or (2) 300 kcmil Al (2) #4-300 kcmil (4) 3/0 Cu or (4) 250 kcmil Al (2) 1/0-300 kcmil or 400 A (2) 600 kcmil Cu (1) 750 kcmil (2) 750 kcmil Al Note: Neutral conductors must be of size and quantity per table above. Metal Directory Frame Feed-through Lugs Mains Rating Actual Lug Wire Range Neutral Conductors Required 100/125 225 Table 9.40: Box Height (20 in. W x 5.75 in. D) Max. No. of Branch Spaces Table 9.32: NQ Main Neutral Conductors—Required Size and Quantity Surge Counter Dry Contacts Remote Monitor $ Price Standard Standard 2588. Note: Additional factory modifications, See Digest page 9-38. 586. 763. 950. Two incoming neutral lugs per panel PE1 Discount Schedule © 2012 Schneider Electric All Rights Reserved NF Merchandised Panelboards 20-inch Wide Enclosures 480Y/277 Vac Max. Class 1670 / Refer to Catalog 1670CT0701 www.schneider-electric.us NEMA 1 Enclosure $ Total Price a Mains Rating Interior Only b Box 20 in. W x 5.75 in. D d NEMA NEMA 1 Catalog No. c $ Price Catalog No. 3R, 5, 12 (Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire 2056. 3638. NF418L1 1446. MH26 18 125 2448. 4030. NF418L1C 1838. MH26 2406. 3970. NF430L1 1766. MH32 30 125 2802. 4366. NF430L1C 2162. MH32 2881. 4435. NF430L2 2219. MH38 30 250 3286. 4840. NF430L2C 2624. MH38 3194. 5021. NF442L2 2418. MH44 42 250 3602. 5429. NF442L2C 2826. MH44 4370. 6067. NF454L2 2616. MH50 54 250 4775. 6472. NF454L2C 3021. MH50 4800. 6485. NF466L2 3800. MH62 66g 250 5442. 7127. NF466L2C 4442. MH62 3308. 5075. NF430L4 2466. MH50 30 400 3716. 5483. NF430L4C 2874. MH50 3572. 5325. NF442L4 2673. MH56 42 400 3895. 5648. NF442L4C 2996. MH56 5285. 6957. NF466L4 4200. MH74 66g 400 5792. 7464. NF466L4C 4707. MH74 6524. 8261. NF484L4 5346. MH86 84g 400 7169. 8906. NF484L4C 5991. MH86 30 600 3838. — NF430L6C 2996. MH50 42 600 4087. — NF442L6C 3188. MH56 66g 600 6094. — NF466L6C 5009. MH74 84g 600 7553. — NF484L6C 6375. MH86 800 Table 9.48: Catalog No. $ Price NC26( ) NC26( ) NC32( ) 113. NC32( ) NC38( ) 113. NC38( ) NC44( ) 113. NC44( ) NC50( ) 113. NC50( ) NC62( ) 113. NC62( ) NC50V( ) 113. NC50V( ) NC56V( ) 113. NC56V( ) NC74V( ) 113. NC74V( ) NC86V( ) 113. NC86V( ) 113. NC50V( ) 113. NC56V( ) 113. NC74V( ) 113. NC86V( ) Factory Assembled Only 113. 497. 527. 549. 663. 729. 887. 729. 786. 972. 1065. 729. 786. 972. 1065. Hinged Front Catalog No. NC26( )HR NC26( )HR NC32( )HR NC32( )HR NC38( )HR NC38( )HR NC44( )HR NC44( )HR NC50( )HR NC50( )HR NC62( )HR NC62( )HR NC50V( )HR NC50V( )HR NC56V( )HR NC56V( )HR NC74V( )HR NC74V( )HR NC86V( )HR NC86V( )HR NC50V( )HR NC56V( )HR NC74V( )HR NC86V( )HR $ Price 620. 657. 687. 830. 912. 887. 912. 983. 1215. 1430. 912. 983. 1215. 1430. NEMA 3R, 5, 12 Enclosure f Enclosure 20 in. W x 6.5 in. D Height (In.) Catalog No. $ Price MH26WP 2192. MH26WP MH32WP 2204. MH32WP MH38WP 2216. MH38WP MH44WP 2603. MH44WP MH50WP 2609. MH50WP MH62WP 2685. MH62WP MH50WP 2609. MH50WP MH56WP 2652. MH56WP MH74WP 2757. MH74WP MH86WP 2915. MH86WP Factory Assembled Only — — 26 32 38 44 56 62 50 56 74 86 50 56 74 — NF Main Circuit Breaker Interiors—Use I-Line Panelboards on 480 V 3Ø3W Delta Applications Max. No. of $ Total Price a One-pole Mains EDB Circuit Rating NEMA NEMA 1 Breakers 3R, 5, 12 NEMA 1 Enclosure NEMA 3R, 5, 12 Enclosure f Main Circuit Main Interior Only b Box Mono-Flat™ Enclosure Breaker Adapter Kit Circuit Hinged Front 20 in. W x 5.75in. D d Front e 20 in. W x 6.5 in. D Height Breaker (In.) Kit $ Price Frame Catalog No. c $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price (Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire 2056. 3638. 15 125 — 2448. 4030. Back-fed EDB, EGB Main or EJB 2406. 3970. Breakerh 27 125 — 2802. 4366. 18 125 30 125 30 250 42 250 54 250 66g 250 30 400 42 400 66g 400 a b c d e f g h i $ Price Mono-Flat™ Front e 2888. 3280. 3322. 3718. 3841. 4246. 4097. 4505. 5278. 5683. 5665. 6307. 4246. 4654. 4514. 4837. 6158. 6665. 4442. 4834. N150MH or 5149. N100MFIi 5545. 5608. 6013. 5850. 6258. N250MJ or 6947. N250MKCi 7352. 7337. 7979. 5931. N400Mi 6339. 6195. N400Mi 6518. 7895. N400Mi 8402. HD/HG/ 780. HJ/HL or FI 780. 780. 780. JD/JG/ JJ/JL or KI 780. 780. 780. 780. LA/LH NF418L1 NF418L1C NF430L1 NF430L1C NF418L1 NF418L1C NF430L1 NF430L1C NF430L2 NF430L2C NF442L2 NF442L2C NF454L2 NF454L2C NF466L2 NF466L2C NF430L4 NF430L4C NF442L4 NF442L4C NF466L4 NF466L4C 1446. 1838. 1766. 2162. 1446. 1838. 1766. 2162. 2219. 2624. 2418. 2826. 2616. 3021. 3800. 4442. 2466. 2874. 2673. 2996. 4200. 4707. MH26 MH26 MH32 MH32 MH38 MH38 MH44 MH44 MH50 MH50 MH56 MH56 MH62 MH62 MH74 MH74 MH62 MH62 MH68 MH68 MH86 MH86 113. 113. 113. 113. 113. 113. 113. 113. 113. 113. 113. NC26( ) NC26( ) NC32( ) NC32( ) NC38( ) NC38( ) NC44( ) NC44( ) NC50( ) NC50( ) NC56( ) NC56( ) NC62( ) NC62( ) NC74( ) NC74( ) NC62V( ) NC62V( ) NC68V( ) NC68V( ) NC86V( ) NC86V( ) 497. 527. 549. 663. 729. 786. 786. 972. 887. 948. 1065. NC26( )HR NC26( )HR NC32( )HR NC32( )HR NC38( )HR NC38( )HR NC44( )HR NC44( )HR NC50( )HR NC50( )HR NC56( )HR NC56( )HR NC62( )HR NC62( )HR NC74( )HR NC74( )HR NC62V( )HR NC62V( )HR NC68V( )HR NC68V( )HR NC86V( )HR NC86V( )HR 620. 657. 687. 830. 912. 983. 983. 1215. 1109. 1185. 1430. MH26WP MH26WP MH32WP MH32WP MH38WP MH38WP MH44WP MH44WP MH50WP MH50WP MH56WP MH56WP MH62WP MH62WP MH74WP MH74WP MH62WP MH62WP MH68WP MH68WP MH86WP MH86WP 2192. 26 2204. 32 2216. 38 2603. 44 2609. 50 2652. 56 2652. 56 2757. 74 2685. 62 2742. 68 2915. 86 Total Price includes: interior, front, main circuit breaker adapter kit, and enclosure. Order branch circuit breakers separately. “C” suffix indicates copper bussing. Embossed mounting holes add a 0.25-inch standoff to back of MH box. Add “F” for flush mount, “S” for surface mount. Enclosure includes trim kit. Use only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits. Back-fed EDB 125 A 3 pole main circuit breaker must be ordered separately and field installed. Maximum breaker rating opposite is 20A. Select the appropriate main circuit breaker from pages starting on 7-21 and add the circuit breaker Price to the total Price of the panelboard. Table 9.49: NF Merchandised SPD Box Selection Table Main Lug Panelboard Box Requirements Mains Rating Max. Breaker Spaces 250A 400 A 42 42 NEMA 1 Enclosure Box MH56 MH68 © 2012 Schneider Electric All Rights Reserved $ Price 113. Front $ Price Hinged $ Price NC56( ) 887. NC56( )HR 1109. NC68V( ) 972. NC68V( )HR 1215. Main Circuit Breaker Panelboard Box Requirements NEMA 3R, 5, 12 Enclosure Enclosure MH56WP MH68WP PE1A $ Price 2685. 2757. Discount Schedule NEMA 1 Enclosure Box MH68 MH80 $ Price 113. Front NC68( ) NC80( ) PANELBOARDS Max No. of Single Pole EDB Circuit Breakers NF Main Lug Interiors—Use I-Line™ Panelboards on 480 V 3Ø3W Delta Applications NEMA 3R, 5, 12 Enclosure $ Price Hinged $ Price Enclosure $ Price 972. NC68( )HR 1215. MH68WP 2742. 1722. M/B NC80V( )HR 1430. MH80WP 2915. 9-13 9 Table 9.47: NF Merchandised Panelboards Accessories Class 1670 / Refer to Catalog 1670CT0701 www.schneider-electric.us 9 Table 9.50: NF Merchandised Neutrals Mains Ampacity 125 250 400 600 PANELBOARDS a 200% Neutral Kit $ Price Box Add 1029. No Adder 1277. 1914. No Adder Factory Assembled Only Catalog No. NFNL1 NFNL2 NFNL4a Schedule Copper 100% Neutral Kit $ Price Box Add Catalog No. NFN1CU NFN2CU NFN6CU NFN6CUa PE-1A PE-1A Schedule 405. No Adder PE-1A 1148. No Adder PE-1A Not to be used with SFL, FTL, or SFB. These combinations are factory assembled only. Table 9.51: Modifications (Single- or Three-phase) Sub-feed Lugs b c Mains Ampacity 125 250 400 600 800 Note: b c d e f Catalog No. $ Price Schedule Catalog No. NF125SFL NF250SFL NF400SFL e 167. 213. 356. — — f Sub-feed Circuit Breaker Kits b (circuit breaker not Included) d Single Sub-feed Twin Sub-feed Circuit Breaker Circuit Breakers Catalog No. $ Price Schedule Catalog No. $ Price NF250SFBH/NF250SFBJ 1029. PE-1A — — — — — NF600SFBH 1290. — — — NF600SFBJ Feed-through Lugs b c PE-1A PE-1A PE-1A — — $ Price Schedule NF125FTL NF250FTL NF400FTL 336. 476. 507. — — f Mains Ampacity PE-1A PE-1A PE-1A — — 250 400 600 FACTORY ASSEMBLED ONLY 800 FACTORY ASSEMBLED ONLY Schedule — PE1A NF250SFBH and NF600SFBH are for use with HDL, HGL, HJL, and HLL circuit breakers. NF600SFBJ are for use with JDL, JGL, JJL, and JLL circuit breakers. Available factory assembled only on non-linear panelboards. Select box from the Box Selection Table. Order appropriate circuit breaker. Use copper wire only. Available factory assembled only. Table 9.52: Special Features Box Selection Table—Standard Mechanical Lugs Only Main Lugs Only Feature Sub-feed Lugs Feed-through Lugs Sub-feed Circuit Breaker No. of Circuits 18 30 42 66 84 18 30 42 66 84 30 42 66 Ampacity 100/125 250 400 600 800 Cat. No. MH26 — — Cat. No. MH32 MH38 MH50 Cat. No. — MH44 MH56 Cat No. — MH62 MH74 Cat No. — — MH86 Cat. No. MH32 — — Cat. No. MH38 MH50 MH56 Cat. No. — MH56 MH62 Cat. No. — MH74 MH80 Cat. No. — — MH92 Cat. No. — MH56 MH68 Cat. No. — MH62 MH74 Cat. No. — MH80 — — g g g g — g g g g g g g g Available factory assembled only. Table 9.53: Special Features Box Selection Table—Standard Mechanical Lugs Only (continued) Feature No. of Circuits Ampacity 100/125 250 400h 600 h Ampacity CU Mechanical Lug Kit CU Compression Lug Kit i Lug Wire Range $ Price Schedule Catalog No. Lug Wire Range $ Price Schedule #6–2/0 AWG NFCUV1 k one #6–1/0 345. 347. PE-1A PE-1A #6–250 kcmil NFCUV2 k one 2/0–300 kcmil 417. one 1/0–750 kcmil, PE-1A NFCUM4 987. PE-1A NFCUV4 one 400–750 kcmil 767. PE-1A two 1/0–350 kcmil PE-1A NFCUM6 two 1/0–750 kcmil 2236. PE-1A NFCUV6 two 250–500 kcmil 1364. PE-1A Contact your local Schneider Electric representative or distributor AL Compression Lug Kit Lug Wire Range $ Price Schedule one #4–300 kcmil 177. PE-1A one 250–350 kcmil 333. 125 250 400 NFALV4 two 2/0–500 kcmil 1122. 600 800 NFALV6 two 2/0–500 kcmil 1206. Catalog No. NFCUM1 NFCUM2 Use copper wire only. Use of this kit requires an additional 6 in. added to box height. Use of this kit to terminate larger than standard wire size requires an additional 6 in. added to box height. NF Accessories Description Aluminum Equipment Ground Bar Copper Equipment Ground Bar Large Aluminum Lug for Equipment Ground Bar Equipment Ground Bar Insulator Kit Circuit I.D. number strips 1–102 odd/even (left side numbered 1, 3, 5...101) 103–204 odd/even (left side numbered 103, 105, 107...203) 1–102 sequential (left side numbered 1, 2, 3 ...102) 103–204 sequential (left side numbered 103, 104, 105... 204) Rail and Deadfront Extensions 6 in. Extension 12 in. Extension 18 in. Extension 9-14 Back-fed Main Circuit Breaker Feed-through Lugs 18 30 Cat. No. Cat. No. MH32 MH38 MH38 MH44 — — — — Optional Main Lug Kits for Main Lug Panelboards Catalog No. NFALV1 j NFALV2 Table 9.55: l Sub-feed Circuit Breaker 30 42 Cat. No. Cat. No. — — MH68 MH74 MH80 MH86 400 A dimension for LA/LH main circuit breakers only. Table 9.54: i j k 18 Cat. No. MH44 — — Vertical Main Circuit Breaker h Feed-through Lugs 30 42 66 Cat. No. Cat. No. Cat. No. MH50 — — MH62 MH68 MH86 MH68 MH74 MH92 Available factory assembled only. Catalog No. PK27GTA PK27GTACU PK23GTAL PKGTAB $ Price Schedule 33.80 DE-3A 84.00 PE-1A 40.70 DE-3A 43.80 NF102OE NF204OE NF102S NF204S 7.90 NF6RDE NF12RDE NF18RDE 252.00 284.00 344.00 PE-1A Description Filler plate (15 per package) EXB Fixed padlock attachment, Lock ON/OFF for ED, EG, and EJ Circuit Breakers 1, 2, or 3 poles EXB Fixed padlock attachment, Lock OFF only for ED, EG, and EJ Circuit Breakers 1, 2, or 3 poles Oversized Lugs for Neutral or Ground Bar #10 to #2 Al or #14 to #4 Cu #4 to #1/0 Al or Cu #1 to #4/0 Al or Cu Drip Hood for 20 in. wide enclosures Catalog No. $ Price Schedule NFFP15 113.00l PE-1A EDPA 26.00 DE-2 EDPAF 30.00 DE-2 QO70AN Q1100AN Q1150AN MHT2DH20 9.90 11.10 32.40 315.00 DE-3A PE-1A PE-1A Filler plates are $7.50 each and must be ordered in packages of 15. PE1A DE3A DE1 Discount Schedule © 2012 Schneider Electric All Rights Reserved Circuit Breakers For NF Merchandised Panelboards Class 515 www.schneider-electric.us Table 9.56: E-frame—125 A, Thermal-magnetic (480Y/277 Vac) ED, EG, EJ “D” Interrupting Level “G” Interrupting Level “J” Interrupting Level Terminal (480Y/277 Vac) 18 kA @ 480Y/277 Vac 35 kA @ 480Y/277 Vac 65 kA @ 480Y/277 Vac Wire Range Hold Trip Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price 1-pole, 277 Vac 15 A EDB14015ab EGB14015ab EJB14015ab AL30FD 20 A EDB14020ab EGB14020ab EJB14020ab 270 875 150. 255. 408. #14–#6 25 A EDB14025b EGB14025b EJB14025b Al or Cu 30 A EDB14030b EGB14030b EJB14030b 35 A EDB14035b EGB14035b EJB14035b 40 A EDB14040b EGB14040b EJB14040b AL100FD 45 A EDB14045b 150. EGB14045b 225. EJB14045b 408. 630 1800 #14–2/0 50 A EDB14050b EGB14050b EJB14050b Al or Cu 60 A EDB14060 EGB14060 EJB14060 70 A EDB14070 302. EGB14070 507. EJB14070 812. 2-pole, 480Y/277 Vac c 15 A EDB24015b EGB24015b EJB24015b AL30FD 20 A EDB24020b EGB24020b EJB24020b 270 875 536. 776. 1241. #14–#6 25 A EDB24025b EGB24025b EJB24025b Al or Cu 30 A EDB24030b EGB24030b EJB24030b 35 A EDB24035b EGB24035b EJB24035b 40 A EDB24040b EGB24040b EJB24040b AL100FD 536. 776. 1241. 45 A EDB24045b EGB24045b EJB24045b 630 1800 #14–2/0 50 A EDB24050b EGB24050b EJB24050b Al or Cu 60 A EDB24060 EGB24060 EJB24060 70 A EDB24070 756. EGB24070 1280. EJB24070 2048. 80 A EDB24080 EGB24080 EJB24080 756. 1280. 2135. 90 A EDB24090 EGB24090 EJB24090 AL100FD 100 A 1000 2300 EDB24100 EGB24100 EJB24100 #14–2/0 Al or Cu 110 A EDB24110 EGB24110 EJB24110 1946. 2586. 3879. 125 A EDB24125 EGB24125 EJB24125 3-pole, 480Y/277 Vac 15 A EDB34015b EGB34015b EJB34015b AL30FD 20 A EDB34020b EGB34020b EJB34020b 270 875 669. 1131. 1358. #14–#6 25 A EDB34025b EGB34025b EJB34025b Al or Cu 30 A EDB34030b EGB34030b EJB34030b 35 A EDB34035b EGB34035b EJB34035b 40 A EDB34040b EGB34040b EJB34040b AL100FD 45 A EDB34045b 669. EGB34045b 1131. EJB34045b 1358. 630 1800 #14–2/0 50 A EDB34050b EGB34050b EJB34050b Al or Cu 60 A EDB34060 EGB34060 EJB34060 70 A EDB34070 911. EGB34070 1292. EJB34070 2562. 80 A EDB34080 EGB34080 EJB34080 911. 1292. 2562. 90 A EDB34090 EGB34090 EJB34090 AL100FD 100 A 1000 2300 EDB34100 EGB34100 EJB34100 #14–2/0 Al or Cu 110 A EDB34110 EGB34110 EJB34110 2421. 3216. 4826. EGB34125 EJB34125 125 A EDB34125 EPDs (Equipment Protection Devices), 1-pole, 277 Vac, Thermal-magnetic with 30 mA ground-fault protectiond 15 A EDB14015EPDab EGB14015EPDab EJB14015EPDab 20 A 270 875 EDB14020EPDab 1151. EGB14020EPDab 1256. EJB14020EPDab 1409. #14–#6 Cu 30 A EDB14030EPDb EGB14030EPDb EJB14030EPDb or #12–#4 Al 40 A EDB14040EPDb EGB14040EPDb EJB14040EPDb 630 1800 1151. 1256. 1409. 50 A EDB14050EPDb EGB14050EPDb EJB14050EPDb Note: All EDB, EGB, and EJB circuit breakers are UL Listed as HACR Type. For 50 oC calibration, use a CA suffix. NF branch circuit breakers are fungus proof as standard. a UL Listed as SWD (Switching duty rated). b UL Listed as HID (High Intensity Discharge rated). c UL Listed for use on 240 V Corner-grounded Delta Systems (Grounded B Phase). See data bulletin 2700DB0202. d All EPDs occupy two spaces, with or without Alarm Switch option. For alarm switch, add 158 list Price and the suffix BA. EDB, EGB, EJB 3-pole 15–125 A Table 9.57: EDB, EGB, EJB 1-pole 15–70 A Factory installed Electrical Accessories Alarm Switch (NO) Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. Application Max Load = 10 A @ 120 Vac 50/60 Hz Terminals for #14 AWG Cu wire Used with control circuits and is actuated only when the circuit breaker has tripped. Table 9.58: Accessory Package Auxiliary Switch/Alarm Switch Packageef Shunt Trip Packageef Auxiliary Switch/Alarm Switch/Shunt Trip Packageef Alarm Switch (N.O.) Package for EPDs only e f Application Max Load = 7 A @ 120 Vac 50/60 Hz Terminals for #14 AWG Cu wire. Factory Installed Electrical Accessory Packages for ED, EG, EJ Circuit Breakers Suffix AABA SA $ Price 312. 755. AABASA 1067. BA 237. Accessory package takes an additional pole space. Not available for EPD. Table 9.59: Terminal Nut Insert Kit Circuit Breaker Type ED, EG, EJ Qty. per Kit 3 Catalog No. TIKFD $ Price 17.40 Minimum Recommended Supply Transformer (VA) 288 50 Shunt Trip—Trips the circuit breaker from a remote location by means of a coil energized from a separate circuit. A 120 V shunt trip will operate at 55% or more of rated voltage. Application For use with momentary or maintained push button. 120 Vac 50/60 Hz Terminals for #14 AWG Cu wire. Coil Burden Max. (VA) Auxiliary Switch (1A/1B) Table 9.60: Table 9.61: 120 V 240 V 480Y/277 V Table 9.62: Circuit Breaker Application Ampere Rating Optional Ampere Rating 15–30 A — — 35–125 A EDB, EGB, EJB 15–30 A g — EDB, EGB, EJB 15–125 A EDB, EGB, EJB — g $ Price 39.00 45.00 25.50 16.80 17.85 Interrupt Ratings (kA) EDB 25 18 (1P), 25 18 EGB 65 35 (1P), 65 35 EJB 100 65 (1P), 100 65 Mechanical Lug Kit Information (Al lugs for use with Al or Cu wire) Standard EDB, EGB, EJB 2-pole 15–125 A Handle Accessories Circuit Breaker Type No. of Poles Catalog No. EXB Fixed Padlock Attachment, Lock ON/OFF ED, EG, EJ 1, 2, or 3 EDPA EXB Fixed padlock attachment, Lock OFF only ED, EG, EJ 1, 2, or 3 EDPAF EXB Removable padlock attachment, Lock OFF only ED, EG, EJ 1, 2, or 3 HPAFD EXB Handle Ties Ties 2 – 1P ECB2HT ED, EG, EJ Ties 3 – 1P ECB3HT Number of Wires Per Lug and Wire Range one #12—#6 AWG Al or one #14—#6 AWG Cu one #12—2/0 AWG Al or one #14—2/0 AWG Cu one #14—1/0 AWG Cu Catalog Number Lugs Per Kit AL30FD 3 AL100FD 3 CU100FD 3 $ price Per Kit 41.30 Factory installed only. Use suffix “LH” E-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55 © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule 9-15 9 EDB-EPD 1-pole with Alarm Switch PANELBOARDS Ampere Rating NF Factory Assembled Panelboards a Maximum 480Y/277 Vac Class 1670 / Refer to Catalog 1670CT0701 www.schneider-electric.us 9 Factory Assembled Pricing a Use I-Line™ Panelboards on 480 V 3Ø3W Delta applications. Table 9.63: Base $ Price (including solid neutral) PANELBOARDS 2-pole 100 A 100 A 125 A 150 A 225 A d 250 A d 400 A d 600 A de 800 A e a b c d e Main Circuit Breaker (Circuit Breaker Interrupt Rating—7-2 through 7-8) a b Main Lugs Mains Rating — — 846. — — 1002 1326. 2366. 3550. Standard IC 3-pole — — 972. — — 1152. 1524. 2622. 3900. Circuit Breaker ED c — ED c HD JD JD LA — — 2-pole HIC 3-pole 1636. — 3372. 3270. 4120. 4500. 5330. — — 1882. — 3762. 3620. 4380. 5140. 6126. — — Circuit Breaker EG c — EG c HG JG JG LH — — Extra HIC 2-pole 3-pole 2100. — 4324. 4048. 5070. 6180. 7712. — — 2416. — 4976. 4398. 5400. 6180. 8864. — — Circuit Breaker — HJ — HJ JJ JJ LC LC — 2-pole I-Limiter™ 3-pole — 3248. — 4070. 6620. 7190. 8506. 9554. — — 3598. — 4420. 7330. 8450. 9776. 10884. — Circuit Breaker — FI — — KI KI LI LI — 2-pole 3-pole — 4250. — — 7266. 9154. 9350. 13640. — — 4884. — — 8352. 10522. 10746. 15678. — HL and JL frame circuit breakers are also available as main circuit breakers. Contact your local Schneider Electric representative or distributor for Micrologic™ trip main circuit breaker pricing. Back-fed main circuit breaker. Prices are for 54-circuit and fewer interiors. See the Product Selector for 66- and 84-circuit interior pricing. Copper bus only. Table 9.64: Branch Circuit Breakers—$ Price per circuit breaker Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR @ 480Y/277 Vac ED Bolt-on Branch Circuit Breaker Ampere Rating High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR @ 480Y/277 Vac EG Bolt-on Branch Extra High Interrupting 100,000 AIR @ 240 Vac, 65,000 AIR @ 480Y/277 Vac EJ Bolt-on Branch 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 324. 15–60 A 192. 442. 748. 746. 1264. 518. 1196. 2024. 70 A 342. 872. 1046. 578. 1474. 1710. 924. 2120. 2540. 80–100 A — 872. 1046. — 1474. 1710. — 2120. 2540. 110–125 A — 2210. 2724. — 4114. 4754. — 5300. 6300. Space Only 42. 84. 126. 42. 84. 126. 42. 84. 126. Note: All ED, EG, and EJ branch circuit breakers are UL Listed as HACR type. Table 9.65: EDB-EPD Equipment Protection Device Branch Circuit Breakers f g Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR @ 480Y/277 Vac ED Bolt-on Branch Circuit Breaker Ampere Rating Extra High Interrupting 100,000 AIR @ 240 Vac, 65,000 AIR @ 480Y/277 Vac EJ Bolt-on Branch 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 1472. — — 1596. — — 1788. — — 15–60 A f g High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR @ 480Y/277 Vac EG Bolt-on Branch All 1-pole EDB-EPD branches use 2 poles of mounting space. For bell alarm in EDB-EPD branch breaker, add 158. to branch breaker price. Sub-feed Circuit Breaker Available on 1Ø or 3Ø, 250–800 A main lugs or 250–600 A main circuit breaker interiors • One sub-feed HD, HG, HJ, or HL or JD, JG, JJ, or JL circuit breaker per 250 A panelboard • Two sub-feed HD, HG, HJ, or HL or two JD, JG, JJ, or JL circuit breakers per 400 A panelboard (do not mix H and J in a Panel) • One sub-feed LA, LH, or LC circuit breaker (400 A max.) and one JD, JG, JJ, or JL circuit breaker or two sub-feed JD, JG, JJ, or JL circuit breakers per 600 A or 800 A panelboard (JJ and LC sub-feed circuit breakers cannot be used together). Table 9.66: Sub-feed Circuit Breaker (150–400 A) No. of Poles 2 3 h HD HG 2456. 2872. LA 4220. 5100. LC h LH 3980. 4916. 5534. 6510. Space 8634. 10156. 826. 826. Sub-feed Circuit Breaker Cabinet Data Max. No. of Branch Spaces (Does not include sub-feed circuit breaker spaces) 30 42 54 66 84 9-16 JG 3020. 3370. JJ and LC sub-feed circuit breakers cannot be used together. Table 9.67: i j k JD 3500. 3798. Box Height (20 in. W x 5.75 in. D) 250 A Main Lugs 56 62 68 80 400 A LA/LH Main Breaker 68 74 80 Main Lugs 68 74 80 600 A Main Breaker 80 86 92 Main Lugs 74 80 86 N/A 800 A Main Breaker i 80k 86k 92k Main Lugs j 68 74 80 N/A 600 A main circuit breaker panelboards require an 8.75 in. deep, 26 in. wide box. 800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box. Dimensions also for 400 A LC/LI main circuit breaker panels. PE1 Discount Schedule © 2012 Schneider Electric All Rights Reserved NF Factory Assembled Panelboards Common Features Class 1670 / Refer to Catalog 1670CT0701 www.schneider-electric.us Sub-feed (Double) Lugs (Standard Aluminum Mechanical Lugs) Table 9.76: An additional mains end termination point that can be used to feed out to another panelboard or device from the incoming service lines. NOTE: Available on main lug interiors only. Sub-feed Wire Range Wire Bending Space per NEC Table 373-6 two #6–2/0 Al or Cu two 1/0–350 kcmil Al or Cu two 1/0–600 kcmil Cu (4) 4/0–500 kcmil Al or Cu (6) 3/0–500 kcmil Al or Cu Mains Rating 125 A 250 A 400 A 600 A 800 A 250 A — 38 44 50 400 A — 50 56 62 Neutral Conductors Required c Actual Lug Wire Range 125 250 (2) 1/0 Cu or (2) 1/0 Al (2) 4/0 Cu or (2) 300 kcmil Al (4) 250 kcmil Al or (4) 3/0 Cuor (2) 600 kcmil Al (4) 500 kcmil Al or (4) 350 kcmil Cu (2) #6-2/0 (2) #6-350 kcmil (2) 1/0-300 kcmil or (1) 1/0-750 kcmil (2) 1/0-750 kcmil 400 A 800 A a — 74 80 86 600 A — 74 80 86 600 Note: Neutral conductors must be of size and quantity per table above. 800 A main lug panelboards require an 8.75 in. deep and 26 in. wide box. Table 9.78: Feed-through Lugs (Standard Aluminum Mechanical Lugs) A second set of lugs assembled at the opposite end from the mains of the panelboard. Often used to connect another panelboard or device to the incoming lines. Available on main lugs and main circuit breaker panelboards. Mains Rating Feed-through Wire Range Wire Bending Space per NEC Table 373-6 125 A 250 A one #6–2/0 kcmil Al or Cu one #6–350 kcmil Al or Cu one 1/0–750 kcmil or two 1/0–350 kcmil Al or Cu two 1/0–600 kcmil Al or Cu 400 A 600 A Table 9.79: 344. 344. 826. Max. No. of Branch Spaces 18 30 42 54 b c 100/125 A 250 A 400 A LA/LH Equipment Ground Bar Copper Ground Bar (Add to Equipment Ground Bar Price) Insulated/Isolated Ground Bar (Add to Equipment Ground Bar Price) Table 9.73: 600 A Hinged Door-in-Door Trim has piano hinge down one side. Inner door has a lock, outer door is retained with screws Hinged Door-in-Door with Outer Door Lock in place of screws Table 9.74: Main Lugs c — 74 80 86 — 56 62 68 Table 9.81: Copper Bus Bars Table 9.82: 100–600 A 800 A 1516. $ Price Per Pole Adder 100 A 58. 70. 70. Main Circuit Breaker Interiors $ Price Adder 38. 52. 86. Aluminum Compression Lugs Copper Mechanical Lugs Copper Compression Lugs Table 9.83: 78. $ Price Adder 458. 624. Standard 100 120 160 200 240 d 400 A 90. 148. 148. 800 A 200. 196. 316. $ Price Per Pole Adder H Frame 59. 70. 70. J Frame 98. 108. 108. LA Frame 128. 148. 148. LC Frame 262. 168. 168. Voltage 208Y/120 V 3Ø4W 11970. 12548. 13807. 17992. 20583. 240/120 V 3Ø4W High Leg 11970. 15654. 13807. 17992. 20583. 480Y/277 V 3Ø4W 12890. 13340. 14623. 20508. 23598. Panelboard box height with SPD unit—Contact your local Schneider Electric representative or distributor. Surgelogic SPD Options Surgelogic SPD Options $ Price Adder 132. 176. 600 A 118. 168. 168. Surgelogic™ Hard Bus SPD—Model IMA d Surge Current Rating kA $ Price Adder 225 A 58. 108. 108. Optional Factory Assembled Lugs for Main Circuit Breaker Interiors Copper Neutral Copper Neutral $ Price Adder Optional Factory Assembled Lugs for Main Lug Interiors Aluminum Compression Lugs Copper Mechanical Lugs Copper Compression Lugs Table 9.84: Table 9.75: 836. Weatherproof or Dusttight Cabinets (Type 3R, 5, 12) Main Lug Interiors Copper Bus Bars 100 A, 250 A 400 A 600 A, 800 A 646. 800 A Main Breaker b Name Plates Name Plates Standard white face/black letter laminated bakelite, 1 in. x 3.5 in., adhesive-backed or screw mountable with screws in a bag assembly (Price includes engraving) Add Per Panel $ Price Hinged Door-in-Door Trim Ground Bars Ground Bars Hinged Door-in-Door Trim Weatherproof or Dusttight Cabinets —Type 3R, 5, 12 (Not available with panelboards having LC/LE/LI/LX/LXI main circuit breakers) 600 A main circuit breaker panelboards require an 8.75 in. deep, 26 in. wide box. 800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box. Table 9.72: 140. 826. Feed-through Lug Cabinet Data (Standard Aluminum Mechanical Lugs) Main Breaker Main Main Main Main Main Main Main (back-fed Lugs Breaker Lugs Breaker Lugs Breaker Lugs only) 38 32 44 — — — — — 44 38 50 50 62 56 68 62 50 — — 56 68 62 74 68 — — — 62 74 68 80 74 $ Price Adder $ Price Box Height in Inches (20 in. W x 5.75 in. D) 125 A Metal Directory Frame Metal Directory Frame Not available with LC/LI main circuit breaker (Replaces standard plastic stick-on directory pouch) Table 9.80: Table 9.71: NF Main Neutral Conductors—Required Size and Quantity Panelboard Ampacity Main Lugs Box Height in Inches (20 in. W x 5.75 in. D) 125 A 26 32 — — 18 30 42 54 Table 9.70: Table 9.77: Sub-feed Lug Cabinet Data (Standard Aluminum Mechanical Lugs) Max. No. of Branch Spaces a 128. 128. 344. 344. 522. Add Per Panel $ Price 769. 950. 1262. 1894. 9 Table 9.69: $ Price 200% Rated Neutrals Panelboards with 200% rated neutrals are available with sub-feed lugs, feed-through lugs, and main circuit breakers 250 A 400 A 600 A 800 A Surge Counter Dry Contacts Remote Monitor $ Price Standard Standard 2588. NOTE: For additional factory modifications, See Digest page 9-38. © 2012 Schneider Electric All Rights Reserved PE1 PANELBOARDS Table 9.68: Discount Schedule 9-17 NQ/NF Merchandised Single Row (Column Width) Panelboards Class 1640 / Refer to Catalog 1670CT0701, 1640CT0801 www.schneider-electric.us 9 PANELBOARDS NQ Single-Row (Column-width)—240 Vac Bolt-on NF Single-Row (Column-width)—480Y/277 Vac Bolt-on (60 A Max. Branch Circuit Breaker) NQ Application Data (60 A Max. Branch Circuit Breaker) NF Application Data Application: For use on ac only. Meet Federal Specification W-P-115c, Type 1, Class 1. UL Listed. Service: 1Ø3W, 3Ø3W, 3Ø4W, 3 Grd. “B” Ø—240 Vac max. AIR: See the tables starting on Digest page 7-2. Mains: Type NQ—Bolt-on main lugs: 100 A, 225 A • Main circuit breaker: 100 A—QOU, 225 A—QB • See the tables starting on Digest page 7-2 for main circuit breaker interrupt ratings. See catalog for terminal lug data. • Main circuit breakers with higher interrupt ratings are available as factory assembled panelboards. Branches: Bolt-on QOB, 60 A maximum. QOB 10-60 A 1-, 2- and 3-pole. See Digest page 9-10 for branch circuit breaker terminal data. QOB-VH and QHB branch circuit breakers are also available as factory assembled. Cabinet: Front—Screw cover. Box—galvanized steel with removable endwalls. Gutters: • 100 A—4 in. min. mains end, 3 in. min. opposite mains • 225 A—10 in. min. mains end, 5 in. min. opposite mains Application: For use on ac only. Meet Federal Specification W-P-115c, Type 1, Class 1. UL Listed. Service: 480Y/277 Vac, 3Ø4W AIR: See the tables starting on Digest page 7-2 Mains: Type NF–Bolt-on main lugs: 125 A, 225 A • Main circuit breaker: 100 A—FA, 100 A—HD, 225 A—JD. See the tables starting on Digest page 7-2 for main circuit breaker interrupt rating. See the catalog section for terminal lug data. • Main circuit breakers with higher interrupt ratings are available as factory assembled panelboards. Table 9.85: Table 9.87: Max. No. of Poles NQ Single-Row (Column-width)—240 Vac Bolt-on a Mains Rating Total Box and Interior with Solid Neutral Front $ Price (8.625 in. W. x 5 in. D.) (Box (Order branch circuit breakers separately) (Surface Mount) Interior Box Height Catalog $ Price and Catalog Number $ Price (In.) Number Front) 1 Phase 3-Wire Main Lugs Only 30 225 1669. NQ830L2C Main Circuit Breaker—2-pole 20 100 1818. NQ820B1C 3 Phase 4-Wire Main Lugs Only 30 100 1608. NQ8430L1C 42 225 1938. NQ8442L2C Main Circuit Breaker—3-pole 30 100 2363. NQ8430B1C 42 225 4961. NQ8442B2C a NF Single-Row (Column-width)—480Y/277 Vac Bolt-on Max. No. Mains of Poles Rating 1298. 45 LX45TS 371. 1452. 40 LX40TS 366. 1242. 1458. 40 58 LX40TS LX58TS 366. 480. 1992. 4416. 45 62 LX45TS LX62TS 371. 545. Total $ Price (Box Interior and Front) Box and Interior with S/N (8.625 in. W. x 5.625 in. D.) Catalog Number Main Lugs Only—3 Phase 4-Wire 30 125 2410. NF8430L1C 42 225 3281. NF8442L2C Main Circuit Breaker—3-pole NF8430M1C 30 100 3767. NF8430M1HDC 42 225 6660. NF8442M2JDC Front (Surface Mount) Box Height (In.) Catalog Number $ Price 2009. 2759. 59 71 NC59TS NC71TS 401. 522. 3246. 65 NC65TS 521. 6042. 85 NC85TS 618. $ Price 60 A Maximum Branch—Copper Bus Standard. Table 9.86: Table 9.88: Cable Troughs and Pull Boxes Cable Troughs (L=Length) b L (In.) 36 48 56 66 b Branches: EDB, EDG, or EDJ, 60 A maximum. See Digest page 9-15 for branch circuit breaker catalog numbers, List Prices and terminal data. Cabinet: Front—Screw cover. Box—galvanized steel with removable endwalls. Gutters: • 100 A—4 in. min. mains end, 3 in. min.opposite mains • 225 A—10 in. min. mains end, 5 in. min. opposite mains 8.625 in. x 5 in. Catalog Number MTX836 MTX848 MTX856 MTX866 $ Price S/N Terminals Catalog Number 42 MPX81542 590. 651. 753. 753. Cable Troughs and Pull Boxes Cable Troughs (L=Length) c Pull Boxes with Solid Neutral $ Price 8.625 in. x 5.625 in. Catalog Number d NTX836 NTX848 NTX856 NTX866 L (In.) 479. 36 48 56 66 Cable troughs are standard with a trough barrier. c d Pull Boxes with Solid Neutral $ Price 590. 651. 753. 753. S/N Terminals Catalog Number 42 MPX81542 $ Price 479. Cable troughs are standard with a trough barrier. Box width = 8.625 in.; width at front, including flange, is 9.625 in.. 20 in. 15 in. Cable Trough Length Solid Neutral Bar Pull Box (Cover Removed) Cable Trough Panel Height Column Width Lighting Panelboard 8 5⁄8 in. 9-18 PE1A Discount Schedule © 2012 Schneider Electric All Rights Reserved NQ/NF Factory Assembled Single Row (Column Width) Panelboards Class 1640 / Refer to Catalog 1670CT0701, 1640CT0801 www.schneider-electric.us NQ Single Row (Column-Width)—240 Vac Bolt-On Factory Assembled Pricing Table 9.89: Base Price with Solid Neutral $ Price Main Lugs 2-Pole Main Circuit Breaker (Circuit Breaker Interrupt Rating—see Digest pages 7-2 through 7-5 3-Pole 100 A 720. 832. 225 A 772. 912. Circuit Breaker 2-Pole QOB QB QD QB QD 3-Pole 1254. Circuit Breaker 2-Pole — — QG — QG — — — — — 1562. 2800. 3434. 2800. 3434. — — — — PANELBOARDS Mains Rating 3-Pole — — 4090. — 4090. Note: Copper bus —standard. Equipment Ground Bar $ Price adder—$38.00. Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder—$52.00. Branch Circuit Breakers (price per breaker) $ Price Circuit Breaker Ampere Rating 1-Pole 120 Vac 2-Pole 120/240 Vac Space Only All Space Only Except Below 28. 10,000 AIR—Branch Circuit Breakers—QOB, QOB-H 15–60 A 68. 10,000 AIR—Qwik-Guard™—Class A—QOB-GFI 15–30 A 272. 40–60 A — Specialty Branch Circuit Breakers (10,000 AIR) For High Intensity Discharge Lighting—QO-HID, QOB-HID 15–30 A 78. 40–50 A 78. High Magnetic Trip (For applications subject to high initial inrush)—QO-HM, QOB-HN 15–20 A 68. — Provides 30 mA Equipment Protection—QO-EPD, QOB-EPD 15–30 A 462. (High Interrupting Capacity) 22,000 AIR Branch Circuit Breakers—QO-VH, QOB-VH 15–30 A 92. 35–60 A — 22,000 AIR—Qwik-Guard—Class A—QO-VHGFI, QOB-VHGFI 15–30 A 294. — 2-Pole 240 Vac 9 Table 9.90: 3-Pole 240 Vac 58. 58. 86. 134. 260. 352. 488. 488. — — — — 148. 148. — — — — — 828. — — 212. 212. — — 376. 462. 462. — — NF Single Row (Column-Width)—480Y/277 Vac 3Ø4W Bolt-on Factory Assembly Pricing Table 9.91: Base Price with Solid Neutral Main Circuit Breaker (Circuit Breaker Interrupt Rating —see Digest pages 7-3 through 7-4 Main Lugs Standard IC Mains Rating 2-Pole 3-Pole Circuit Breaker HIC $ Price 2-Pole 3-Pole Extra HIC $ Price Circuit Breaker 2-Pole 3-Pole — FA — 2184. FH — 100 A — 1074. — 2842. — HD HG 125 A — — 3222. — 150 A — HD — 3222. HG — 1272. 225 A — JD — 4784. JG — Note: Copper bus—standard. Copper Neutral $ Price adder—$132.00. Equipment Ground Bar $ Price adder—$38.00. Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder—$52.00. Table 9.92: 3044. 3792. 4172. 4172. 5982. I-Limiter™ $ Price Circuit Breaker 2-Pole — 3-Pole — — — — — HJ HJ JJ — 4374. 4754. 4754. 8902. Circuit Breaker — FI KI $ Price 2-Pole 3-Pole — — — — — KI — 7392. 13150. 13150. Branch Circuit Breakers (price per breaker) $ Price Circuit Breaker Ampere Rating Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR @480Y/277 Vac ED Bolt-on Branch 1-Pole 15–60 A Space Only Table 9.93: 2-Pole 192. 42. 3-Pole 442. 84. High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR @480Y/277 Vac EG Bolt-on Branch 1-Pole 748. 126. 2-Pole 324. 42. 3-Pole 746. 84. Extra High Interrupting 100,000 AIR @ 65,000 AIR @ 480Y/277 Vac EJ Bolt-on Branch 1-Pole 1264. 126. 2-Pole 518. 42. 3-Pole 1196. 84. 2024. 126. EDB-EPD Equipment Protection Device Branch Circuit Breakers $ Price Circuit Breaker Ampere Rating Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR @480Y/277 Vac ED Bolt-on Branch 1-Pole 15–60 A © 2012 Schneider Electric All Rights Reserved 1472. 2-Pole 3-Pole — — High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR @480Y/277 Vac EG Bolt-on Branch 1-Pole 1596. PE-1 Discount Schedule 2-Pole 3-Pole — — Extra High Interrupting 100,000 AIR @ 65,000 AIR @ 480Y/277 Vac EJ Bolt-on Branch 1-Pole 1788. 2-Pole 3-Pole — — 9-19 I-Line™ and QMB Panelboards Pricing Procedure and Examples Class 2110, 4620 / Refer to Catalog 2110CT9701, 4620CT9601 www.schneider-electric.us 9 I-Line Merchandised Pricing Procedure PANELBOARDS 1. Select the appropriate branch circuit breakers and accessories based on the required ampacity and AIR ratings from Digest pages 9-24 through 9-30. 2. Determine the total mounting inches required by the branch circuit breakers. Pay close attention to the interior types and any branch mounting restrictions by referring to panel layouts on Digest pages 9-21 and 9-22. For example, larger frame circuit breakers may mount in only one side of the panel due to physical sizes. Therefore, for larger size branches, you may only be able to consider one half of the total mounting inches available. 3. Select proper main lug interior or main circuit breaker interior from Digest page 9-21 or 9-22 based on the mains ampacity and branch requirements from step 2. 4. Select blanks from the Accessories table on Digest page 9-23 as required to cover unused mounting space. 5. Select appropriate box and front from Digest page 9-21 or 9-22 to accommodate panel interior selected in step 3. 6. Apply appropriate discount schedule. Table 9.94: I-Line Merchandised Pricing Example 600 Vac, 3Ø3W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door. Description Catalog No. Digest Page No. 400 Amp MLO Interior 4 Piece Surface Trim Without Door Type 1 Enclosure (8) 60/3 one 100/2 one 4.5 in. Blanks one 1.5 in. Blank HCM32734 HCM73TS HC3273B FA36060 FA26100AC HNM4BL HNM1BL 9-21 9-21 9-21 9-25 9-25 9-23 9-23 $ Price 2408. 699. 243. 7764. 947. 126. 44. Total Price 12231. I-Line Factory Assembled Pricing Procedure 1. Select price for main lugs or main circuit breaker from Base Price tables on Digest page 9-31. Include solid neutral and ground bar when required. 2. List branch circuit breakers and determine total mounting inches required. Include space only charge and mounting inches as required. Price branches from Digest page 9-32. 3. If total space required exceeds the maximum listed, price as two or more panels and add price for sub-feed lugs, so installer can cable between sections. 4. Add price for special features from Digest page 9-34. 5. For complete price, total all prices. Order panel by description. 6. Apply appropriate discount schedule. Table 9.95: I-Line Factory Assembled Pricing Example 600 Vac, 3Ø3W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door. Description Digest Page No. 400 A MLO Base Price (8) 60/3 one 100/2 (3) 250/3 9-31 9-32 9-32 9-32 $ Price 2799. 12072. 1446. 17100. Total Price 33417. QMB Factory Assembled QMB Panelboards—Method of Pricing 1. Make a sketch with main lugs or main switch at the top or bottom. 2. List required branch devices (switches and circuit breaker units). Include ampere rating, number of poles, and unit mounting height from the appropriate table on Digest pages 9-35 and 9-36. 3. 30–60 twin units are the same price as 600 V 60–60 twin units. 4. 30–100 and 60–100 twin units are the same price as 600 V 100–100 twin units. 5. List solid neutral from Digest page 9-36 if required. No unit mounting height is required. 6. List mains ampere rating, voltage, number of poles, and unit mounting space from the appropriate table on 9-36. 7. If total unit mounting height of branch devices exceeds maximum mounting space of the mains, price as two or more panelboards, adding sub-feed lugs or feed-thru lugs from the appropriate table on Digest page 9-36. 8. Insert at the right of each item the price from the appropriate table, including any accessories. The sum will be the complete panelboard price including the cabinet. 9. Specify H, R, or J fuse clips. Table 9.96: QMB Factory Assembled Pricing Example 600 Vac, 3Ø3W, 400 A, Fusible 10k AIR, Type 1 Enclosure Branches Digest Page No. 400 A MLO Base Price (4) 60/3 one 100/3 one 30/3 9-36 9-36 9-36 — Total Price 9-20 Example pricing only Discount Schedule $ Price 2016. 4338. 3411. — 9765. © 2012 Schneider Electric All Rights Reserved I-Line™ Merchandised Panelboards 600 Vac, 250 Vdc Class 2110 / Refer to Catalog 2110CT9701 www.schneider-electric.us Table 9.97: TYPE HCN 1⁄2 Total Breaker Mounting Space Each Side 600 A Max. Main Lugs or 400 A Max. Main Breaker S N Box Size: 26 in. Wide, 6.5 in. Deep TYPE HCM 250 A max. branch circuit breaker FA, FH, FY, FI, QB, QD, QG, QJ, HD, HG, HJ, HL, JD, JG, JJ, JL QB, QD QG, QJ QB, QD QG, QJ FA, FH FI, FY FA, FH FI, FY HD, HG HJ, HL HD, HG HJ, HL JD, JG JJ, JL JD, JG JJ, JL 1⁄2 Total Breaker Mounting Space Each Side S N 800 A Max. Main Lugs or 800 A Max. Main Breaker Box Size: 32 in. Wide, 8.25 in. Deep TYPE HCP-SUh 800 A max. main circuit breaker 600 A max. branch circuit breaker FY, FA, FH, FI, KI, LA, LD, LG, LJ, LL, LH, LC, LX, LI, LXI, LE, MG, MJ, PG, PJ, PL, PGC, PJC, PLCj, QB, QD, QG, QJ, HD, HG, HJ, HL, JD, JG, JJ, JL FY, FA, FH, FI HD, HG, HJ, HL QB, QD, QG, QJ JD, JG, JJ, JL, KI MG, MJ, PG, PJ, PL PGC, PJC, PLC S N 800 A Max. Main Lugs or 800 A Max. Main Breaker a b c d e f g h j k l m © 2012 Schneider Electric All Rights Reserved 4 Piece Trim Without Door b Trim With Door Catalog Number Catalog Number Catalog Number $ Price $ Price $ Price NEMA 3R/5/12 d (Includes Front) Type 1 Catalog Number $ Price Catalog Number $ Price Box Height (In.) Type 3R/ 5/12 $ Price Box c HCN Main Lugs Only 3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i 225 A 2171. 4004. HCN14522N 1593. 27 400 A 2195. 4028. HCN14524 1617. HCN52T( ) 335. HCN52T( )D 411. HC2652B 600 A 2392. 4225. HCN14526 1814. 225 A 2674. 4402. HCN23652N 1991. 45 400 A 2702. 4430. HCN23654 2019. HCN65T( ) 440. HCN65T( )D 530. HC2665B 600 A 2960. 4688. HCN23656 2277. 225 A 3135. 4709. HCN32742N 2298. 63 400 A 3156. 4730. HCN32744 2319. HCN74T( ) 594. HCN74T( )D 717. HC2674B 600 A 3396. 4970. HCN32746 2559. 225 A 3548. 6233. HCN41832N 2552. 81 400 A 3564. 6249. HCN41834 2568. HCN83T( ) 753. HCN83T( )D 890. HC2683B 600 A 3824. 6509. HCN41836 2828. 225 A 4175. 6767. HCN50922N 3086. 99 400 A 4341. 6933. HCN92T( ) 846. HCN92T( )D 1001. HC2692B HCN50924 3252. 600 A 4434. 7026. HCN50926 3345. HCN Main Circuit Breaker e k Includes 3-pole, vertically mounted main circuit breaker—Suitable for use as service equipment 27 400 A 6649. 8377. HCN14654M 5966. 100 A 3860. 5588. HCN18651MN 3177. HCN65T( ) 440. HCN65T( )D 530. HC2665B 36 225 A 5303. 7031. HCN18652MN 4620. 45 400 A 7287. 8861. HCN23744M 6450. 100 A 4323. 5897. HCN27741MN 3486. HCN74T( ) 594. HCN74T( )D 717. HC2674B 54 225 A 5759. 7333. HCN27742MN 4922. 225 A 6068. 8753. HCN32832MN 5072. 63 HCN83T( ) 753. HCN83T( )D 890. HC2683B 400 A 7836. 10521. HCN32834M 6840. 81 400 A 8154. 10746. HCN41924M 7065. HCN92T( ) 846. HCN92T( )D 1001. HC2692B 90 225 A 6590. 9182. HCN45922MN 5501. HCM Main Lugs Only 3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i 225 A 2279. 4566. HCM14482N 1644. 400 A 2404. 4691. HCM14484 1769. 27 HCM48T( ) 392. HCM48T( )D 483. HC3248B 600 A 3175. 5462. HCM14486 2540. 800 A 3709. 5996. HCM14488 3074. 225 A 2795. 5717. HCM23642N 2036. 400 A 2891. 5813. HCM23644 2132. 45 HCM64T( ) 516. HCM64T( )D 633. HC3264B 600 A 3530. 6452. HCM23646 2771. 800 A 4041. 6963. HCM23648 3282. 225 A 3263. 6002. HCM32732N 2321. 400 A 3350. 6089. HCM32734 2408. 63 HCM73T( ) 699. HCM73T( )D 864. HC3273B 600 A 3921. 6660. HCM32736 2979. 800 A 4644. 7383. HCM32738 3702. 225 A 4205. 7918. HCM50912N 2966. 400 A 4281. 7994. HCM50914 3042. 99 HCM91T( ) 996. HCM91T( )D 1217. HC3291B 3347. 600 A 4586. 8299. HCM50916 800 A 5321. 9034. HCM50918 4082. HCM Main Circuit Breaker e k Includes 3-pole, vertically mounted main circuit breaker—Suitable for use as service equipment. 27 400 A 7563. 10485. HCM14644M 6804. HCM64T( ) 516. HCM64T( )D 633. HC3264B 225 A 5582. 8504. HCM18642MN 4823. 36 600 A 11648. 10706. HCM18736MP 10706. HCM73T( ) 699. HCM73T( )D 864. HC3273DB9m 800 A 14549. 13607. HCM18738MP 13607. 45 400 A 8007. 10746. HCM23734M 7065. HCM73T( ) 699. HCM73T( )D 864. HC3273B 54 225 A 5969. 8708. HCM27732MN 5027. 600 A 12377. 11138. HCM36916MP 11138. 72 HCM91T( ) 996. HCM91T( )D 1217. HC3291DB9m 800 A 15431. 14192. HCM36918MP 14192. 81 400 A 9315. 13028. HCM41914M 8076. HCM91T( ) 996. HCM91T( )D 1217. HC3291B HCP-SU g Universal Single Row Main Lugs or Main Circuit Breaker k 3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i 54 800 5858. 9466. HCP54868SU 4514. HC2686T( )4P 1101. HC2686T( )HRf 1658. HC2686DB i Box Size: 26 in. Wide, 9.5 in. Deep Type 1 $ Price Front a Interior Assembly (Less Branch Circuit Breakers) 243. HC2652WP 2411. 52 243. HC2665WP 2411. 65 243. HC2674WP 2411. 74 243. HC2683WP 3681. 83 243. HC2692WP 3681. 92 243. HC2665WP 2411. 65 243. HC2674WP 2411. 74 243. HC2683WP 3681. 83 243. HC2692WP 3681. 92 243. HC3248WP 2922. 48 243. HC3264WP 3681. 64 243. HC3273WP 3681. 73 243. HC3291WP 4952. 91 243. HC3264WP 3681. 64 243. Use HCP 243. HC3273WP 243. Use HCP — — 3681. 73 — — 243. HC3291WP 4952. 91 243. HC2886WP 4952. 86 Add “F” for flush mount, “S” for surface mount. Add-on door kit available from Peru. Example: For HCM48TS surface trim kit, order HCM48DS door kit. For Type 1 applications, order interior, front, and box. For Type 3R/5/12 applications, order interior and box only. The front is included with the box. Remove drain screws for Type 3R rating. Bottom feed standard. Hinged trim with door. For main lugs panel, order sub-feed lug kit and back-feed as main lugs. For main circuit breaker panel, order plug-on I-Line type PG, PJ, PL, MG, or MJ circuit breakers from 9-28 through 9-30 and backfeed as the main breaker (order solid neutral from 9-22). Suitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided and the panelboard is not used as a lighting and appliance branch circuit panelboard. PG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. “C” suffix denotes a 100% rating. Circuit breaker interrupt ratings, starting on Digest page 7-2. I-Line Surgelogic SPD not available. DB9 box is 9.5 inches deep. PE1A Discount Schedule 9-21 PANELBOARDS FA, FH FY HD, HG HJ, HL Complete Surface $ Price (4 Piece Trim) (Less Branch Circuit Breakers) 9 FA, FH FY HD, HG HJ, HL Mains Ampere Rating QB, QD QG, QJ Total Circuit Breaker Mounting Space (In.) 225 A max. (240 V max.) branch circuit breaker QB, QD, QG, QJ 150 A max. branch circuit breaker FA, FH, FY, HD, HG, HJ, HL l QB, QD QG, QJ Interiors, Boxes and Fronts (100 A and 225 A interiors include solid neutral, all others without solid neutral. Order solid neutral from 9-23) I-Line™ Merchandised Panelboards 600 Vac, 250 Vdc Class 2110 / Refer to Catalog 2110CT9701 www.schneider-electric.us TYPE HCP PANELBOARDS 800 A max. branch circuit breaker FAa, FH, FI, FY, QB, QD, QG, QJ, HD, HG, HJ, HL, JD, JG, JJ, JL, KI, LA, LD, LG, LJ, LL, LH, LC, LI, LX, LXI, LE, MG, MJ, PG, PJ, PL, PGC, PJC, PLCb QB, QD QG, QJ FA, FH, FY HD, HG HJ, HL FI, KI, JD JG, JJ, JL FA, FH, FY HD, HG HJ, HL QB, QD QG, QJ FI, KI, JD JG, JJ, JL LD, LG, LJ LL, LA, LH LC, LI, LX LXI, LE MG, MJ, PG, PJ, PL, PK, PGC PJC, PKC, PLC 1⁄2 Total Breaker Mounting Space Each Side S N 1200 A Max. Main Lugs or 800 A Max. Main Breaker Box Size: 42 in. Wide, 9.5 in. Deep a FA and JDA circuit breakers with field installable ground fault kits may be mounted in type HCP, HCP-SU, and HCR-U panelboards as shown, and require L-frame mounting space. PG, PJ, and PL circuit breakers are available with both thermalmagnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. “C” suffix denotes a 100% rating. b TYPE HCR-U Universal Mains 1200 A max. branch circuit breaker FAc, FH, FI, FY, QB, QD, QG, QJ, HD, HG, HJ, HL, JD, JG, JJ, JL, KI, LA, LD, LG, LJ, LL, LH, LC, LI, LX, LXI, LE, MG, MJ, PG, PJ, PL, PGC, PJC, PLC, RGC, RJC, RLCde 1⁄2 Total Breaker Mounting Space Each Side FA, FH, FY HD, HG HJ, HL QB, QD QG, QJ QB, QD QG, QJ FA, FH, FY HD, HG HJ, HL FI, KI, JD JG, JJ, JL FI, KI, JD JG, JJ, JL Total Circuit Breaker Mtg. Space (In.) (1200 A Interiors Include solid neutral, all others without solid neutral. Order solid neutral from 9-23.) Max. No. of LC, MJ, PL, RL Circuit Breakers Mains Amp. Rating 9 Table 9.98: 1200 A Max. Main Lugs or 1200 A Max. Main Breaker S/N Box Size: 44 in. Wide, 9.5 in. Deep c d e 9-22 FA and JDA circuit breakers with field installable ground fault kits may be mounted in type HCP, HCP-SU, and HCRU panelboards as shown, and require L-frame mounting space. When RL main circuit breakers with equipment ground fault are applied on a 3Ø4W system, order solid neutral catalog number HCR12SNCT. The HCR12SNCT includes a neutral current transformer. PG, PJ, and PL circuit breakers are available with both thermalmagnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. “C” suffix denotes a 100% rating. Catalog Number Type 1 $ Price Box h Box Height (In.) 4 Piece Trim Without Door g Trim With Door Catalog Number $ Price Catalog Number HCW50T( ) 606. HCW50T( )D 743. HC4250DB 243. 50 HCW59T( ) 671. HCW59T( )D 827. HC4259DB 243. 59 HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 68 HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 86 HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 68 HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 86 243. 86 $ Price Catalog Number $ Price HCR-U Universal Main Lugs or Main Circuit Breakerj—3-pole Suitable for use as service equipment when provided with a main circuit breaker. For Main Lugs panel, order sub-feed lug kit catalog number S33930 and back feed as main lugs. For Main Circuit Breaker panel, order plug-on I-Line type PG, PJ, PL, RGC, RJC, or RLCk circuit breakers from pages 9-27 through 9-29, and back feed as the main circuit breaker. (Order solid neutral separately) 108 l f g h i j k l m 1200 6PL or 3RLC 12557. HCR548612U 11213. Table 9.99: 1101. HCR86T( )D 1344. HC4486DB Circuit Breaker / Sub-feed Lug Kit Mounting Space Requirement FY FA, FH FA, FH FA, FH, SL-100 FI HD, HG HD, HG HJ, HL QB, QD, QG, QJ Maximum Ampacity 30 A 100 A 150 A 225 A No. of Poles 1 1 2 3 2, 3 2 3 2, 3 2 Inch Mounting Requirements 1.5 1.5 3 4.5 4.5 3 4.5 4.5 3 Type of Circuit Breaker QB, QD, QG, QJ JD, JG, JJ, JL, KI, SL250 LA, LH, SL400 LD, LG, LJ, LL LC, LI, LXI MG, MJ, MA, MH, SL800, PGC, PJC, PLC PG, PJ, PL, S33931 RG, RJ, RL, RGC, RJC, RLC, S33930 Table 9.100: Main Circuit Breaker Interiors —Standard Frame Types n Main Circuit Breaker Ampacity Panelboard Type Factory Supplied Main Circuit Breaker 100 225 HCN HCN, HCM HCN HCM FA36100 JDA36225 LAP36400MB LAP36400MB MGP36600 or MGP36800 400 600 or 800 n HCR86T( )m Add “F” for flush mount, “S” for surface mount. Add-on door kit available. Example: For HCW50TS trim kit, order HCW50D door kit. See Digest page 9-23 for 42 in. wide weatherproof enclosures. Suitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided and the panelboard is not used as a lighting and appliance branch circuit panelboard. Circuit breaker interrupt ratings, starting on Digest page 7-2. When RL main circuit breakers with equipment ground fault are applied on a 3Ø4W system, order solid neutral catalog number HCR12SNCT. The HCR12SNCT includes a neutral current transformer. 15 in. of mounting space is taken up by the back fed main lug kit or RG, RJ, RL main circuit breaker, leaving 93 in. of branch circuit breaker mounting space. Add-on door kit available. Example: For HCR86TS trim kit, order HCW86D door kit. Type of Circuit Breaker MG, MJ PG, PJ, PK, PL, PGC, PJC, PKC, PLC RG, RJ, RK, RL, RGC, RJC RKC, RLC Front f Interior Assembly (Less Branch Circuit Breakers) HCP Main Lugs Only—3-pole Suitable for use as service equipment when provided with a main circuit breaker. i 400 2751. HCP14504 1902. 600 3513. HCP14506 2664. 27 1PL 800 4521. HCP14508 3672. 1200 6365. HCP145012N 5516. 400 3212. HCP23594 2298. 600 3860. HCP23596 2946. 45 2PL 800 4874. HCP23598 3960. 1200 7133. HCP235912N 6219. 400 3795. HCP32684 2706. 600 4476. HCP32686 3387. 63 3PL 800 5309. HCP32688 4220. 1200 7763. HCP326812N 6674. 400 4716. HCP50864 3372. 600 5208. HCP50866 3864. 99 5PL 800 6194. HCP50868 4850. 1200 8529. HCP508612N 7185. HCP Main Circuit Breakerj—Includes 3-pole Vertically mounted main circuit breaker—Suitable for use as service equipment. 600 12179. HCP18686M 11090. 36 2LC 800 15399. HCP18688M 14310. 600 12987. HCP36866M 11643. 72 4LC 800 16296. HCP36868M 14952. LD, LG, LJ LL, LA, LH LC, LI, LX LXI, LE Complete Surface $ Price (4 Piece Trim) (Less Branch Breakers) HCM, HCP Maximum Ampacity 225 A 250 A 400 A 600 A 600 A No. of Poles 3 2, 3 Inch Mounting Requirements 4.5 4.5 6 6 7.5 800 A 9 1200 A 1200 A 15 Table 9.101: Standard Copper Bus Interiors Type Main Ampacity HCN HCM, HCP-SU HCP, HCR-U 600 800 800 and Above Note: Merchandised copper interiors are not available in all ampacities. For example, if the application calls for a HCN 225 A copper bus interior, order an HCN 600 A interior . Circuit breaker interrupt ratings, starting on Digest page 7-2. PE1A Discount Schedule © 2012 Schneider Electric All Rights Reserved I-Line™ Merchandised Panelboards Accessories Class 690, 2110 / Refer to Catalog 2110CT9701 www.schneider-electric.us Table 9.102: I-Line Merchandised Panelboard Accessories Equipment Ground Bar 800 A Solid Neutral 1200 A 1200 A, for use with HCR-U universal panel only 1200 A, Including neutral CT for 3Ø4W systems Equipment Ground Bar Kits—HCN HCM, HCP, HCR-U Blank Extensions (For replacement purposes) 1.5 in. for mounting on wide side of I-Line panelboard (minimum order 3) e 4.5 in. for mounting on wide side of I-Line panelboard (minimum order 5) e 1.5 in. for mounting on narrow side of I-Line panelboard (minimum order 3) e 4.5 in. for mounting on narrow side of I-Line panelboard (minimum order 5) e 4.5 in. for mounting on wide side of I-Line panelboard (minimum order 5) e 4.5 in. for mounting on narrow side of I-Line panelboard (minimum order 5) e a b c d e Table 9.103: Blank Extensions All applications, except Powerpact H/J with Micrologic trip unit 5/6 All applications, except Powerpact H/J with Micrologic trip unit 5/6 Only Powerpact H/J circuit breakers with Micrologic trip unit 5/6 Only Powerpact H/J circuit breakers with Micrologic trip unit 5/6 HLW1BL HLW4BL HLN1BL HLN4BL HLW4EBL HLN4EBL 252.00 333.00 464.00 717.00 1151.00 1269.00 843.00 1151.00 1269.00 33.80 104.00 14.30 25.20 14.30 25.20 25.20 25.20 Used on Type HCN, HCM. Used on 400 A, 600 A, 800 A, and 1200 A HCP (main lugs), and 600 A and 800 A (main circuit breaker). Used on Type HCP-SU. Used on Type HCR-U. Blank extension pricing is per unit. Multiply the list price by the quantity ordered. Note minimum order quantity. Table 9.104: Panelboard Adapter Kits Circuit Breaker Mounting Ht. Application HC2SN HC4SNa, HCW4SNb HC6SNa, HCW6SNb HC8SNa, HCW8SNb HCPSU8SNc HCPSU8SNCTc HCW12SNb HCWM12SNd HCR12SNCTd PK27GTA PK32DGTA $ Price 14.30 25.20 1.5 in. 4.5 in. 1.5 in. 4.5 in. Branch Circuit Side Catalog Number 4.5 in. HLW1BL Wide Side HLW4BL HLN1BL Narrow Side HLN4BL Narrow HLN4EBL Side 4.5 in. Wide Side HLW4EBL I-Line Panelboard Type Crimp Lug Adapter Kits f HCN HCN400VCA HCN600VCA — — 400 A 600 A 800 A 1200 A f g HCP, HCR-U g HCW400VCA HCW600VCA HCW800VCA HCW1200VCA HCM HCM400VCA HCM600VCA HCM800VCA — $ Price 96. 197. 284. 491. For use with MLO panel, order VCEL lugs seperately. Not for use with P- or R-frame circuit breakers or sub-feed kits S33930 or S33931. Table 9.105: Type 3R/5/12 Enclosures Catalog Number Interior Type HC4250WP HC4259WP HC4268WP HC4286WP HC4486WP HCP HCP HCP HCP HCR-U Dimensions (In.) $ Price H 50 59 68 86 86 4952. 4952. 4952. 4952. 4952. W 42 42 42 42 44 D 12.95 12.95 12.95 12.95 14.50 Table 9.106: Box Extensions Catalog Number Interior Type Extension HC2609DEX (F or S) HCP-SU 9 in. $ Price 552. HC2609EX (F or S) HCN 9 in. 552. HC3209EX (F or S) HCM 9 in. 552. HC4212DEX (F or S) HCP 12 in. 641. HC4406DEX (F or S) HCR-U 6 in. 552. HC4412DEX (F or S) HCR-U 12 in. 641. Blank Extensions Table 9.107: Sub-feed Lug Kits hi Ampere Rating 100 A 250 A 250 A 400 A In. (mm) 4.5 114 SL100 4.5 114 SL250 4.5 114 SL250 6 152 SL400j 9 229 1200 A 1200 A 9 15 229 S33931 381 S33930 SL800 435. 435. 435. 585. 1731. 1731. 3500. 3500. Max. Short Circuit System Ratings RMS Symmetrical Amperes 240 Vac 65,000 125,000 200,000 65,000 65,000 125,000 100,000 125,000 480 Vac 25,000 100,000 200,000 35,000 65,000 100,000 65,000 100,000 600 Vac 18,000 50,000 100,000 25,000 25,000 50,000 25,000 50,000 Protected by Circuit Breaker FH JL KI LH MJ LL MJ, PJ RL For Use in I-Line Panelboard Types HCN, HCM, HCP, HCP-SU HCM, HCP, HCP-SU HCP, HCP-SU HCM, HCP, HCP-SU HCP, HCP-SU, HCR-U Plug-on in same manner as a branch circuit breaker For other ratings, See the I-Line Information Manual, #80043-309-xx. SL400 cannot be used in HCM panelboards due to inadequate wire bending space. Table 9.108: Sub-feed Lug kit terminal data Catalog No. (Prefix) SL100 SL250 SL400 SL800 S33931 S33930 For Surgelogic™ I-Line plug-on SPD unit pricing and information, see Digest pages 6-3 and 6-4. For field-installable I-Line door kits, see the Supplemental and Obsolescence Digest, Section 4. k © 2012 Schneider Electric All Rights Reserved Catalog Number $ Price 800 A h i j Sub-feed Lug Kits Height No. Poles 3 3 3 3 3 3 Ampere Rating 100 A 250 A 400 A 800 A 1200 A 1200 A Std. Lug Kit Catalog No. AL100FA — AL400LA AL900MA AL1200P24K AL1200R53K Standard Lug Wire Size k #14–1/0 AWG Cu or #12–1/0 AWG Al #4 AWG–300 kcmil one #1 AWG–600 kcmil or two #1 AWG–250 kcmil (3) #3/0 AWG–500 kcmil (4) #3/0 AWG–500 kcmil (4) #3/0 AWG–600 kcmil Unless otherwise specified, wire sizes apply to both aluminum and copper conductors. 9-23 PANELBOARDS Blank Fillers Catalog No. HNM1BL HNM4BL 9 Description Blank Fillers—1.5 in. (minimum order 3) e Blank Fillers—4.5 in. (minimum order 5) e Solid Neutral Assemblies 225 A 400 A 600 A Circuit Breakers F-frame, PowerPact D-frame for I-Line™ Panelboards and Switchboards Class 650, 651 www.schneider-electric.us 9 Table 9.109: QO™ Distribution Panel—240 Vac Max. Only Mounts in Type HCN, HCM, HCP, HCP-SU, or HCR-U I-Line panelboards, 30 A max. branch circuit breaker. Order QO plug-on circuit breakers from page 9-34. Maximum No. 1-pole Phase QO Circuit Breakers Connection PANELBOARDS 6 6 6 6 a AB BC AC ABC Mounting Height In. 4.5 4.5 4.5 4.5 2-pole Catalog Number mm 114 114 114 114 3-pole Catalog Number HQO206AB HQO206BC HQO206AC — Table 9.114: F-frame—100 A, Thermal-magnetic (240 Vac) Ampere Rating $ Price a — — — HQO306 369. 369. 369. 369. Includes (5) QO1DB dummy circuit breakers. FA/FH, 1-pole 1.5 in (38 mm) Mounting Height FA/FH, 3-pole 4.5 in (114 mm) Mounting Height FA/FH, 2-pole 3 in (76 mm) Mounting Height Table 9.110: Example: FJA, 20 A 1-pole, 277 Vac and 70 A 2- and 3-pole QB 240 Vac. Use phase option number for HD, HG, HJ, HL, JD, JG, JJ, JL, MG, and MJ. Phase Option Number 1 3 5 1 2 3 4 5 6 Standard b 6 b Phase Connection 1-pole 2-pole 3-pole A B C AB AC BA BC CA CB ABC CBA FJA140201 FJA140203 FJA140205 — — — — — — — — — — — QBA220701 QBA220702 QBA220703 QBA220704 QBA220705 QBA220706 — — — — — — — — — — — QBA32070 QBA320706 1-pole 2-pole 3-pole — — — FA24030AB FA24030AC FA24030BC — — — — — — — — FA34030 FA34030CBA Table 9.112: Interrupt Ratings (kA) 240 V 277 V 480 V 600 V FA (240 V) 10 — — — FA (480 V) 18 (1P), 25 (2, 3P) 18 18 — FJ 65 65 — — F-frame accessories . . . . . . . . . starting on Supplemental Digest page 3-24 F-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54 F-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-51 PowerPact™ D-frame Mission Critical Circuit Breakers When the D-frame Mission Critical circuit breaker is used as a main circuit breaker with QO branch circuit breakers, the D-frame MC will remain closed during any fault that occurs downstream of the QO circuit breaker up to 30kA at 208Y/120 Vac. Table 9.113: PowerPact D-frame, 150–600 A–Mission Critical Circuit Breaker Cat.alog Number c DJA32150W DJA32250W DJA32400W DJA32600W Continuous Current Rating 150 A 250 A 400 A 600 A Terminal Wire Range (AWG/kcmil) $ Price #2-600 Cu or #2-500 Al (2) 2/0-350 Cu or (2) 2/0-500Al 10867. 10867. 10867. 17148. c D-frame circuit breakers 400 A and below are 100% rated. D-frame accessories, lugs . . . . . starting on Supplemental Digest page 3-27 D-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55 9-24 600 850 1450 1700 600 850 1450 1700 Terminal Wire Range Standard Interrupting Catalog Number $ Price FA22015( FA22020( FA22025( FA22030( FA22035( FA22040( FA22045( FA22050( FA22060( FA22070( FA22080( FA22090( FA22100( FA32015 FA32020 FA32025 FA32030 FA32035 FA32040 FA32045 FA32050 FA32060 FA32070 FA32080 FA32090 FA32100 ) ) ) ) ) ) ) ) ) ) ) ) ) AL50FA #14–#4 AWG Cu or #12–#4 AWG Al 398. AL100FA #14–#1/0 AWG Cu or #12–#1/0 AWG Al 617. 572. AL50FA #14–#4 AWG Cu or #12–#4 AWG Al 572. AL100FA #14–#1/0 AWG Cu or #12–#1/0 AWG Al 572. 780. AL100FA #14–#1/0 AWG Cu or #12–#1/0 AWG Al 780. AL100FA #14–#1/0 AWG Cu 1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix. AC Magnetic Standard Interrupting Extra High Interrupting Terminal Wire Range Ampere Trip Settings Rating Catalog Catalog FY/FA FJ/FC Lugs Hold Trip $ Price Number $ Price Number Lugs 1-pole, 277 Vac, 125 Vdc e 15 A FY14015( )f FJA14015( ) AL50FA AL30FD #14-#4 #12–#6 20 A FY14020( )f FJA14020( ) 275 600 149. 651. AWG Cu, or AWG Al, or 25 A FY14025( )f FJA14025( ) #12-#4 #14–#6 30 A FY14030( )f FJA14030( ) AWG Al AWG Cu 35 A FA14035( )g FJA14035( ) 40 A FA14040( )g FJA14040( ) 400 850 302. 651. 45 A FA14045( )g FJA14045( ) AL100FA AL100FD 50 A FA14050( )g FJA14050( ) #14–#1/0 #12–#2/0 AWG Al 60 A FA14060( )g FJA14060( ) 651. AWG Cu or or 800 1450 FA14070( )g 302. FJA14070( ) 70 A 720. #12–#1/0 #14–#2/0 AWG Al AWG Cu 80 A FA14080( )g — — 90 A FA14090( )g — — 900 1700 302. 100 A FA14100( )g — — 2-pole, 480 Vac, 250 Vdc efg 15 A FA24015( ) — — AL50FA CU30FA4 #14–#4 20 A FA24020( ) — — one #14– 275 600 651. AWG Cu or #10 AWG 25 A FA24025( ) — — #12–#4 Cu only 30 A FA24030( ) — — AWG Al 35 A FA24035( ) — — 40 A FA24040( ) — — 400 850 651. 45 A FA24045( ) — — AL100FA AL100FA4 #14–#3 50 A FA24050( ) — — #14–#1/0 one Cu AWG Cu or AWG 60 A FA24060( ) 651. — — or #12–#1/0 one #12–#1 800 1450 FA24070( ) 70 A — — 833. AWG Al AWG Al 80 A FA24080( ) — — 90 A FA24090( ) — — 900 1700 833. 100 A FA24100( ) — — 3-pole, 480 Vac, 250 Vdc e 15 A FA34015 — — AL50FA CU30FA4 #14–#4 20 A FA34020 — — one #14– 275 600 833. AWG Cu or #10 AWG 25 A FA34025 — — #12–#4 Cu only 30 A FA34030 — — AWG Al 35 A FA34035 — — 40 A FA34040 — — 400 850 833. 45 A FA34045 — — AL100FA AL100FA4 50 A FA34050 — — #14–#1/0 one #14–#3 Cu AWG Cu or AWG 60 A FA34060 833. — — or #12–#1/0 one #12–#1 800 1450 70 A FA34070 — — 996. AWG Al AWG Al 80 A FA34080 — — 90 A FA34090 — — 900 1700 996. 100 A FA34100 — — e f g DE2 Trip Table 9.115: F-frame—100 A, Thermal-magnetic (480 Vac) Table 9.111: Example: FA, 30 A, 480 Vac. Use phase option letters for FH, FI, KI, LA, LH, LC, and LI. FA14035A FA14035B FA14035C — — — — — Hold 2-pole, 240 Vac d 15 A 20 A 275 25 A 30 A 35 A 40 A 400 45 A 50 A 60 A 70 A 800 80 A 90 A 900 100 A 3-pole, 240 Vac 15 A 20 A 275 25 A 30 A 35 A 40 A 400 45 A 50 A 60 A 70 A 800 80 A 90 A 900 100 A d The absence of a phase option number after a 3-pole catalog number will result in an ABC phase connection. Phase Option Letter A B C AB AC BC ABC CBA AC Magnetic Trip Settings Discount Schedule 1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix. Rated 277 Vac 15 and 20 A FY circuit breakers are rated for switching duty (SWD). 15, 20, 25, and 30 A FA I-Line circuit breakers are also available (no SWD rating). Rated 277 Vac, 125 Vdc, except FY circuit breakers, which have no dc rating. 15–30 A circuit breakers suitable for use with 60 oC or 75 oC conductors. 35–100 A circuit breakers are suitable for use with 75 oC conductors. © 2012 Schneider Electric All Rights Reserved Circuit Breakers F-frame, PowerPact Q-frame for I-Line™ Panelboards and Switchboards Class 650, 734, 820 www.schneider-electric.us Table 9.116: F-frame—100 A, Thermal-magnetic (600 Vac) Standard Interrupting FI36100 2- and 3-pole 4.5 in (114 mm) Mounting Height Catalog Number $ Price — — — — — — — — — — — — — — — — — — — — — — — — — — 850 1450 1700 Catalog Number FH16015( FH16020( FH16025( FH16030( FH16035( FH16040( FH16045( FH16050( FH16060( FH16070( FH16080( FH16090( FH16100( ) ) ) ) ) ) ) ) ) ) ) ) ) FH26015( FH26020( FH26025( FH26030( FH26035( FH26040( FH26045( FH26050( FH26060( FH26070( FH26080( FH26090( FH26100( ) ) ) ) ) ) ) ) ) ) ) ) ) Terminal Wire Range Current Limiting $ Price 507. 507. 507. 563. 563. Catalog Number $ Price — — — — — — — — — — — — — — — — — — — — — — — — — — AL50FA #14–#4 AWG Cu or #12–#4 AWG Al AL100FA #14–#1/0 AWG Cu or #12–#1/0 AWG Al a 600 850 1450 1700 600 850 1450 1700 FA26015( FA26020( FA26025( FA26030( FA26035( FA26040( FA26045( FA26050( FA26060( FA26070( FA26080( FA26090( FA26100( ) ) ) ) ) ) ) ) ) ) ) ) ) 780. 780. 780. 947. 947. FA36015 FA36020 FA36025 FA36030 FA36035 FA36040 FA36045 FA36050 FA36060 FA36070 FA36080 FA36090 FA36100 971. 971. 971. 1163. 1163. 1214. 1214. 1214. 1452. 1452. FH36015 FH36020 FH36025 FH36030 FH36035 FH36040 FH36045 FH36050 FH36060 FH36070 FH36080 FH36090 FH36100 1446. 1446. 1446. 1632. 1632. — FI26020( — FI26030( — FI26040( — FI26050( FI26060( FI26070( FI26080( FI26090( FI26100( — 2763. — 2763. — 2763. — 2763. ) ) ) ) ) ) ) ) ) 2763. AL50FA #14–#4 AWG Cu or #12–#4 AWG Al AL100FA #14–#1/0 AWG Cu or #12–#1/0 AWG Al 2763. — FI36020 — FI36030 — FI36040 — FI36050 FI36060 FI36070 FI36080 FI36090 FI36100 — 3459. — 3459. — 3459. — 3459. 3459. AL50FA #14–#4 AWG Cu or #12–#4 AWG Al AL100FA #14–#1/0 AWG Cu or #12–#1/0 AWG Al 3459. a 1- and 2-pole circuit breaker catalog numbers are completed by adding the required connection letters as a suffix, See Digest page 9-24. NOTE: As of January 1st, FI breakers will only fit on the wide side of I-Line panelboards. Table 9.117: PowerPact™ Q-frame b— 225 A, Thermal-magnetic (240 Vac) QB/QD/QG/QJ Mounting Height: 2-pole—3 in (76 mm) 3-pole—4.5 in (114 mm) AC Magnetic Trip Settings Hold Trip 2-pole, 240 Vac c 70 A 80 A 1000 1800 90 A 100 A 110 A 125 A 150 A 1200 2400 175 A 200 A 225 A 3-pole, 240 Vac d 70 A 80 A 1000 1800 90 A 100 A 110 A 125 A 150 A 1200 2400 175 A 200 A 225 A Ampere Rating b c d "B" Interrupting Catalog Number QBA22070( QBA22080( QBA22090( QBA22100( QBA22110( QBA22125( QBA22150( QBA22175( QBA22200( QBA22225( ) ) ) ) ) ) ) ) ) ) QBA32070( QBA32080( QBA32090( QBA32100( QBA32110( QBA32125( QBA32150( QBA32175( QBA32200( QBA32225( ) ) ) ) ) ) ) ) ) ) "D" Interrupting $ Price 600. 600. 1913. 1913. Catalog Number QDA22070( QDA22080( QDA22090( QDA22100( QDA22110( QDA22125( QDA22150( QDA22175( QDA22200( QDA22225( ) ) ) ) ) ) ) ) ) ) QDA32070( QDA32080( QDA32090( QDA32100( QDA32110( QDA32125( QDA32150( QDA32175( QDA32200( QDA32225( ) ) ) ) ) ) ) ) ) ) "G" Interrupting $ Price 1202. 1202. 2069. 2069. Catalog Number QGA22070( QGA22080( QGA22090( QGA22100( QGA22110( QGA22125( QGA22150( QGA22175( QGA22200( QGA22225( ) ) ) ) ) ) ) ) ) ) QGA32070( QGA32080( QGA32090( QGA32100( QGA32110( QGA32125( QGA32150( QGA32175( QGA32200( QGA32225( ) ) ) ) ) ) ) ) ) ) "J" Interrupting $ Price 1593. 1593. 2835. 2835. Catalog Number QJA22070( QJA22080( QJA22090( QJA22100( QJA22110( QJA22125( QJA22150( QJA22175( QJA22200( QJA22225( ) ) ) ) ) ) ) ) ) ) QJA32070( QJA32080( QJA32090( QJA32100( QJA32110( QJA32125( QJA32150( QJA32175( QJA32200( QJA32225( ) ) ) ) ) ) ) ) ) ) $ Price 1992. 1992. 3245. 3245. Replacement lugs are not available on QB, QD, QG, or QJ circuit breakers. Lugs for QB, QD, QG, or QJ circuit breakers accept one #4 AWG–300 kcmil. No accessories are available for PowerPact Q Frame breakers. 2-pole QB, QD, QG, and QJ circuit breakers are completed by adding the required phasing numbers as indicated in the parentheses, See Digest page 9-24. 3-pole QB, QD, QG, and QJ circuit breakers for ABC phasing are complete without additional phasing number. For CBA phasing, complete the catalog number by inserting the number “6” in the parentheses. Table 9.118: Interrupt Ratings (kA) 240 V 480 V 600 V e FA 25 18 14 FH 25 (1P 35–100 A), 65 (1P 15–30 A, 2P, 3P) 25 (2, 3P) 18 (2, 3P) 100 QB 10 — — QD 25 — — QG 65 — — QJ e 100 — — 3-pole QJ circuit breakers are rated at 208Y/120 Vac only. F-frame accessories . . . . . . . . . starting on Supplemental Digest page 3-24 F-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-54 F-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-51 © 2012 Schneider Electric All Rights Reserved FI 200 DE2 Discount Schedule Q-frame accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-38 . . . . . . . . . . . . . . . . . . . . . . . . . . .starting on Supplemental Digest page 3-24 Q-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54 Q-frame optional lugs . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-29 9-25 9 30 A 35 A 40 A 400 45 A 50 A 60 A 70 A 800 80 A 90 A 900 100 A 2-pole, 600 Vac, 250 Vdc 15 A 20 A 275 25 A 30 A 35 A 40 A 400 45 A 50 A 60 A 70 A 800 80 A 90 A 900 100 A 3-pole, 600 Vac, 250 Vdc 15 A 20 A 275 25 A 30 A 35 A 40 A 400 45 A 50 A 60 A 70 A 800 80 A 90 A 900 100 A High Interrupting PANELBOARDS AC Magnetic Trip Settings Hold Trip 1-pole, 277 Vac, 125 Vdc a 15 A 20 A 275 600 25 A Ampere Rating Circuit Breakers H- and J-frame for I-Line™ Panelboards and Switchboards Class 612 www.schneider-electric.us 9 Table 9.119: H-frame 150 A Thermal-Magnetic UL Current-Limitinga Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unitb Suitable for Reverse Connectionb Current Rating @ 40o C Fixed AC Magnetic Trip Interrupting Rating (2nd Letter of Catalog Number) G Ja La $ Price 80% Rated 80% Rated 80% Rated 80% Rated D Cat. No.c PANELBOARDS Hold Trip H-frame, 150A 2P, 600 Vac 50/60 Hz, 250 Vdca 15 A 350 A 750 A H( )A26015( ) 899. 1338. 1589. 20 A 350 A 750 A H( )A26020( ) 899. 1338. 1589. 25 A 350 A 750 A H( )A26025( ) 899. 1338. 1589. 30 A 350 A 750 A H( )A26030( ) 899. 1338. 1589. 35 A 400 A 850 A H( )A26035( ) 899. 1338. 1589. 40 A 400 A 850 A H( )A26040( ) 899. 1338. 1589. 45 A 400 A 850 A H( )A26045( ) 899. 1338. 1589. 50 A 400 A 850 A H( )A26050( ) 899. 1338. 1589. 60 A 800 A 1450 A H( )A26060( ) 899. 1338. 1589. 70 A 800 A 1450 A H( )A26070( ) 1088. 1559. 1824. 80 A 800 A 1450 A H( )A26080( ) 1088. 1559. 1824. 90 A 800 A 1450 A H( )A26090( ) 1088. 1559. 1824. 100 A 800 A 1700 A H( )A26100( ) 1088. 1559. 1824. 110 A 900 A 1700 A H( )A26110( ) 2195. 3212. 4671. 125 A 900 A 1700 A H( )A26125( ) 2195. 3212. 4671. 150 A 900 A 1700 A H( )A26150( ) 2195. 3212. 4671. H-frame 150A 3P, 600 Vac 50/60 Hz, 250 Vdc 15 A 350 A 750 A H( )A36015 1124. 1575. 1988. 20 A 350 A 750 A H( )A36020 1124. 1575. 1988. 25 A 350 A 750 A H( )A36025 1124. 1575. 1988. 30 A 350 A 750 A H( )A36030 1124. 1575. 1988. 35 A 400 A 850 A H( )A36035 1124. 1575. 1988. 40 A 400 A 850 A H( )A36040 1124. 1575. 1988. 45 A 400 A 850 A H( )A36045 1124. 1575. 1988. 50 A 400 A 850 A H( )A36050 1124. 1575. 1988. 60 A 800 A 1450 A H( )A36060 1124. 1575. 1988. 70 A 800 A 1450 A H( )A36070 1361. 1772. 2225. 80 A 800 A 1450 A H( )A36080 1361. 1772. 2225. 90 A 800 A 1450 A H( )A36090 1361. 1772. 2225. 100 A 800 A 1700 A H( )A36100 1361. 1772. 2225. 110 A 900 A 1700 A H( )A36110 2730. 3779. 5432. 125 A 900 A 1700 A H( )A36125 2730. 3779. 5432. 150 A 900 A 1700 A H( )A36150 2730. 3779. 5432. a 2 pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix see Table 9.128. Terminal Wire Range 2364. 2483. 2483. 2483. 2483. 2483. 2483. 2483. 2483. 2681. 2681. 2681. 2681. 5699. 5699. 5699. AL150HD 14–3/0 AWG Al or Cu 2993. 2993. 2993. 2993. 2993. 2993. 2993. 2993. 2993. 3243. 3243. 3243. 3243. 6951. 6951. 6951. AL150HD 14–3/0 AWG Al or Cu Table 9.120: J-frame 250 A Thermal-Magnetic UL Current-Limitinga Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unitb Suitable for Reverse Connectionb Current Rating @ 40oC Adjustable AC Magnetic Trip D Cat. No.c Interrupting Rating (2nd Letter of Catalog Number) G Ja La $ Price 80% Rated 80% Rated 80% Rated Low High 80% Rated J-frame 250A 2P, 600 Vac 50/60 Hz, 250 Vdca 150 A 750 A 1500 A J( )A26150( ) 2283. 3372. 4904. 5985. 175 A 875 A 1750 A J( )A26175( ) 2283. 3372. 4904. 5985. 200 A 1000 A 2000 A J( )A26200( ) 2283. 3372. 4904. 5985. 225 A 1125 A 2250 A J( )A26225( ) 2283. 3372. 4904. 5985. 250 A 1250 A 2500 A J( )A26250( ) 3138. 4463. 6536. 7338. J-frame 250A 3P, 600 Vac 50/60 Hz, 250 Vdc 150 A 750 A 1500 A J( )A36150 2867. 3968. 5705. 7299. 175 A 875 A 1750 A J( )A36175 2867. 3968. 5705. 7299. 200 A 1000 A 2000 A J( )A36200 2867. 3968. 5705. 7299. 225 A 1125 A 2250 A J( )A36225 2867. 3968. 5705. 7299. 250 A 1250 A 2500 A J( )A36250 3936. 5252. 7599. 9173. a 2 pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix see Table 9.128. Ra Terminal Wire Range 80% Rated AL175JD 4–4/0 AWG Al or Cu AL250JD 3/0 AWG–350 kcmil Al or Cu — — — — — AL175JD 4–4/0 AWG Al or Cu AL250JD 3/0 AWG–350 kcmil Al or Cu 9676. 9676. 9676. 9676. 11729. Table 9.121: H-frame 150 A and J-frame 250 A Electronic Trip UL Current-Limitinga Circuit Breakers (600 Vac) With Factory Sealed Trip Unitb Suitable for Reverse Connection d Electronic Trip Unit Type Function Trip Unit Sensor Rating D Cat. No.c 80% Rated Interrupting Rating (2nd Letter of Catalog Number) G Ja La $ Price 80% 80% 80% Rated Rated Rated Ra Terminal 80% Rated 600 Vac, 50/60 Hz, 3P LI 3.2g Micrologic Standard Micrologic Ammeter Micrologic Energy Micrologic Ammeter Micrologic Energy a b c d e f g 9-26 LSI 3.2Sg LSI 5.2A LSI LSIG LSIG 5.2E 6.2A 6.2E 60 A 100 A 150 A 250 A 60 A 100 A 150 A 250 A 60 A 100 A 150 A 250 A 60 A 100 A 150 A 250 A 60 A 100 A 150 A 250 A 60 A 100 A 150 A 250 A H( )A36060U31X H( )A36100U31X H( )A36150U31X J( )A36250U31X H( )A36060U33X H( )A36100U33X H( )A36150U33X J( )A36250U33X H( )A36060U43X H( )A36100U43X H( )A36150U43X J( )A36250U43X H( )A36060U53X H( )A36100U53X H( )A36150U53X J( )A36250U53X H( )A36060U44X H( )A36100U44X H( )A36150U44X J( )A36250U44X H( )A36060U54X H( )A36100U54X H( )A36150U54X J( )A36250U54X 1316. 1569. 2911. 3120. 1512. 1765. 3107. 3398. 2143. 2396. 3738. 4299. 2523. 2776. 4118. 4840. 2902. 3156. 4497. 5381. 3282. 3535. 4877. 5921. 1743. 1962. 3965. 4226. 1939. 2159. 4161. 4505. 2570. 2789. 4792. 5406. 2950. 3169. 5172. 5947. 3330. 3549. 5551. 6487. 3709. 3929. 5931. 7028. 2224. 2382. 5626. 5970. 2420. 2578. 5823. 6249. 3051. 3209. 6453. 7150. 3431. 3589. 6833. 7691. 3811. 3969. 7213. 8231. 4190. 4349. 7593. 8772. 3173. 3490. 7288. 7715. 3370. 3686. 7484. 7994. 4001. 4317. 8115. 8895. 4380. 4697. 8495. 9436. 4760. 5077. 8875. 9976. 5140. 5456. 9254. 10517. 4171. 4591. 9631. 10102. 4393. 4813. 9853. 10420. 5185. 5653. 10836. 11561. 5883. 6333. 11342. 12413. 6423. 6873. 11864. 13157. 6963. 7413. 12386. 13900. AL150HDe AL250JDf AL150HDe AL250JDf AL150HDe AL250JDf AL150HDe AL250JDf AL150HDe AL250JDf AL150HDe AL250JDf Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting. See Supplemental Digest pages 3-2 and 3-3 for circuit breakers with field-interchangeable trip units To complete catalog number, replace the blank with the appropriate rating (D, G, J, L). For applications requiring communications, see Digest page 7-49. AL150HD wire range is 14–3/0 AWG Al or Cu. AL250JD wire range is 3/0 AWG–350 kcmil Al or Cu. For smaller wire range (4–4/0 AWG Al or Cu), replace the lug’s wire binding screws with the larger binding screws provided. 3P circuit breakers with this trip unit can be used for 2P applications. DE2 Discount Schedule © 2012 Schneider Electric All Rights Reserved Circuit Breakers K-, PowerPact H-, J-, L-frame for I-Line™ Panelboards and Switchboards Class 825, 0612 www.schneider-electric.us Table 9.122: K-frame—250 A, Thermal-magnetic, Current Limiting (600 Vac) Current Limiting Low High 2-pole, 600 Vac, 250 Vdc a 110 A 550 125 A 625 150 A 750 175 A 875 200 A 1000 225 A 1125 250 A 1250 1100 1250 1500 1750 2000 2250 2500 KI26110( KI26125( KI26150( KI26175( KI26200( KI26225( KI26250( 3-pole, 600 Vac, 250 Vdc 110 A 125 A 150 A 175 A 200 A 225 A 250 A 1100 1250 1500 1750 2000 2250 2500 KI36110 KI36125 KI36150 KI36175 KI36200 KI36225 KI36250 Terminal Wire Range $ Price ) ) ) ) ) ) ) 6633. 6633. 6633. 6633. 6633. 6633. 7704. AL250KA one #4 AWG– 350 kcmil Al or Cu AL250KI one #1/0 AWG– 350 kcmil Al or Cu 8375. 8375. 8375. 8375. 8375. 8375. 9267. AL250KA one #4 AWG– 350 kcmil Al or Cu AL250KI one #1/0 AWG– 350 kcmil Al or Cu 2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See Digest page 9-24. 9 a 550 625 750 875 1000 1125 1250 Catalog Number PANELBOARDS AC Magnetic Trip Settings Ampere Rating KI36250 2- and 3-pole 4.5 in (114 mm) Mounting Height J-Frame Mission Critical Circuit Breaker Table 9.123: J-frame 250 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac) With Factory Sealted Trip Units Suitable for Reverse Connectiona Electronic Trip Unit Type Trip Continuous Function Trip Unit Current D Interrupting Cat. No. JDA34250WU31X JDA34250WU33X JDA34250WU43X JDA34250WU53X JDA34250WU44X JDA34250WU54X G Interrupting $ Price 3619. 3931. 4939. 5544. 6148. 6753. Standard LI 3.2 W 250 Standard LSI 3.2S-W 250 High Perf. Ammerter LSI 5.2A-W 250 High Perf. Energy LSI 5.2E-W 250 High perf. Ammerter LSIG 6.2A-W 250 High Perf. Energy LSIG 6.2E-W 250 a Standard rated (80%). Not available in 100% rated. b AL250JD terminal wire range is (1) 3/0 AWG–350 kcmil Al or Cu. Cat. No. JGA34250WU31X JGA34250WU33X JGA34250WU43X JGA34250WU53X JGA34250WU44X JGA34250WU54X J Interrupting $ Price 4857. 5169. 6176. 6782. 7386. 7991. Cat. No. JJA34250WU31X JJA34250WU33X JJA34250WU43X JJA34250WU53X JJA34250WU44X JJA34250WU54X L Interrupting $ Price 6808. 7119. 8127. 8732. 9336. 9942. Cat. No. JLA34250WU31X JLA34250WU33X JLA34250WU43X JLA34250WU53X JLA34250WU44X JLA34250WU54X $ Price 8759. 9071. 10079. 10684. 11288. 11893. Terminal AL250JDb AL250JDb AL250JDb AL250JDb AL250JDb AL250JDb L-Frame Mission Critical Circuit Breaker Table 9.124: L-frame 600 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac) With Factory Sealted Trip Units Suitable for Reverse Connectiona Electronic Trip Unit Type Trip Continuous Function Trip Unit Current D Interrupting Cat. No. LDA34250WU31X LDA34400WU31X LDA34600WU31X LDA34250WU33X LDA34400WU33X LDA34600WU33X LDA34400WU43X LDA34600WU43X LDA34400WU53X LDA34600WU53X LDA34400WU44X LDA34600WU44X LDA34400WU54X LDA34600WU54X G Interrupting $ Price 5991. 5991. 8684. 6656. 6656. 9349. 7674. 10366. 8791. 11485. 9911. 12604. 11029. 13722. Cat. No. LGA34250WU31X LGA34400WU31X LGA34600WU31X LGA34250WU33X LGA34400WU33X LGA34600WU33X LGA34400WU43X LGA34600WU43X LGA34400WU53X LGA34600WU53X LGA34400WU44X LGA34600WU44X LGA34400WU54X LGA34600WU54X 250 Standard LI 3.3 W 400 600 250 Standard LSI 3.3S-W 400 600 400 High Perf. Ammeter LSI 5.3A-W 600 400 High Perf. Energy LSI 5.3E-W 600 400 High Perf. Ammeter LSIG 6.3A-W 600 400 High Perf. Energy LSIG 6.3E-W 600 a Standard rated (80%). Not available in 100% rated. b AL400L61K3 terminal wire range is (1) #2 AWG–500 kcmil Al or #2 AWG–600 kcmil Cu.. c AL600LF52K3 terminal wire range is (2) #3/0 AWG–500 kcmil Al or Cu. $ Price 6291. 6291. 9126. 6990. 6990. 9826. 8062. 10896. 9238. 12074. 10417. 13251. 11594. 14429. J Interrupting L Interrupting Cat. No. $ Price LJA34250WU31X 10299. LJA34400WU31X 10299. LJA34600WU31X 12733. LJA34250WU33X 10999. LJA34400WU33X 10999. LJA34600WU33X 13433. LJA34400WU43X 12070. LJA34600WU43X 14503. LJA34400WU53X 13247. LJA34600WU53X 15681. LJA34400WU44X 14426. LJA34600WU44X 17139. LJA34400WU54X 15602. LJA34600WU54X 18036. Cat. No. LLA34250WU31X LLA34400WU31X LLA34600WU31X LLA34250WU33X LLA34400WU33X LLA34600WU33X LLA34400WU43X LLA34600WU43X LLA34400WU53X LLA34600WU53X LLA34400WU44X LLA34600WU44X LLA34400WU54X LLA34600WU54X $ Price 11998. 11998. 14263. 12698. 12698. 14962. 13769. 16033. 14946. 17210. 16125. 18388. 17301. 19566. Terminal AL400L61K3b AL600LF52K3c AL400L61K3b AL600LF52K3c AL600LF52K3c AL600LF52K3c AL600LF52K3c AL600LF52K3c Table 9.125: PowerPact™ H-, J-, and L-frame Automatic Molded Case Switches, 600 Vac Circuit Ampere Breaker Poles Rating G Withstand L Withstand R Withstand Trip Cat. No. $ Price Point Cat. No. $ Price Trip Point Cat. No. $ Price Trip Point 150 A HGA26000S15( ) 1349. 2250 A HLA26000S15 1590. 2250 A — — — 2a 175 A JGA26000S17( ) 1827. 3125 A JLA26000S17 1980. 3125 A — — — 250 A JGA26000S25( ) 1827. 3125 A JLA26000S25 1980. 3125 A — — — H-frame J-frame 150 A HGA36000S15 1799. 2250 A HLA36000S15 1988. 2250 A HRA36000S15 2295. 2250 A 3 175 A JGA36000S17 2286. 3125 A JLA36000S17 2475. 3125 A JRA36000S17 2860. 3125 A 250 A JGA36000S25 2286. 3125 A JLA36000S25 2475. 3125 A JRA36000S25 2860. 3125 A 400 A LGA36000S40X 4572. 4800 A LLA36000S40X 4972. 4800 A LRA36000S40X 5688. 4800 A L-frame 3 600 A LGA36000S60X 5065. 6600A LLA36000S60X 5465. 6600 A LRA36000S60X 6220. 6600 A a 2-pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix, see Table 9.128. Table 9.126: KI Interrupt Ratings (kA) V 240 480 600 Table 9.127: Interrupt Ratings (kA) KI 200 200 100 240 V 480 V D 25 18 G 65 35 K-frame accessories . . . . . . . . . .starting on Supplemental Digest page 3-25 K-frame dimensions. . . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-33 K-frame optional lugs. . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-28 H-, J-, and L-frame accessories . . . . . . . . . . . . .starting on Digest page 7-36 H-, J-, and L-frame dimensions. . . . . . . . . . . . . .starting on Digest page 7-54 H-, J-, and L-frame optional lugs. . . . . . . . . . . . . . . . . . . . . . Digest page 7-39 © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule Terminal Wire Range — — — AL150HD AL175JD AL250JD AL150HD AL250JD — — — 14 AWG–3/0 AWG Al/Cu 4–4/0 AWG Al/Cu 3/0 AWG–350 kcmil Al/Cu AL600LS52K3 (2) 2/0 AWG–500 kcmil Al/Cu Table 9.128: Phase Options—Example HDA26150( ) J 100 65 L 125 100 Phase Option Number 1 2 3 4 5 6 Standard 6 Phase Connection 2-pole 3-pole AB AC BA BC CA CB ABC CBA HDA261501 HDA261502 HDA261503 HDA261504 HDA261505 HDA261506 — — — — — — — — JDA34250WU31X JDA34250WU31X6 9-27 Circuit Breakers LA Mission Critical for I-Line™ Panelboards and Switchboards Class 660, 665, 670, 830 www.schneider-electric.us 9 LA Mission Critical Circuit Breakers The LA High Magnetic Withstand MC Circuit Breakers are designed to trip at a higher magnetic trip level (18–20 times handle rating) than typical molded case circuit breakers (MCCBs) (which trip at 5–10 times the handle rating). The high magnetic withstand value of these LA circuit breakers allow the downstream branch circuit breaker to clear the fault. Table 9.129: L-frame—400 A, I-Line™ LA/LH MC High Magnetic Withstand Circuit Breaker For Mission Critical Loads PANELBOARDS Ampere Rating AC Magnetic Level Factory Set a Standard Interrupting Hold Cat. No. Trip LA/LH MC Circuit Breaker, 3P, 480 Vac 200 A 3400 A 4000 A 225 A 3825 A 4500 A 250 A 4250 A 5000 A 400 A a 6000 A 7200 A High Interrupting $ Price Cat. No. LA34200MC LA34225MC LA34250MC 5571. 5571. 5681. LH34200MC LH34225MC LH34250MC LA34400MC 6941. LH34400MC Terminal $ Price Cat. No. 8771. 8771. AL250LAMC 8882. 10142. AL400LA Wire Range (1) 250–350 kcmil Al (1) 3/0 AWG–350 kcmil Cu (1) 1 AWG–600 kcmil Al or (2) 1 AWG–250 kcmil Al AC magnetic setting tolerances are +0 -25% from maximum value shown. Table 9.130: L-frame—400 A, Thermal-magnetic (600 Vac) Ampere Rating LA/LH 2- and 3-pole 6 in (152 mm) Mounting Height Low 2-pole, 600 Vac, 250 Vdc b 125 A 625 150 A 750 175 A 875 200 A 1000 225 A 1125 250 A 1250 300 A 1500 350 A 1750 High Standard Interrupting Catalog Number High Interrupting $ Price Catalog Number $ Price 1250 1500 1750 2000 2250 2500 3000 3500 LA26125( LA26150( LA26175( LA26200( LA26225( LA26250( LA26300( LA26350( ) ) ) ) ) ) ) ) 4053. 4053. 4053. 4053. 4053. 4053. 4053. 4053. LH26125( LH26150( LH26175( LH26200( LH26225( LH26250( LH26300( LH26350( ) ) ) ) ) ) ) ) 6762. 6762. 6762. 6762. 6762. 6762. 6762. 6762. 2000 4000 LA26400( ) 4053. LH26400( ) 6762. 3-pole, 600 Vac, 250 Vdc 125 A 625 150 A 750 175 A 875 200 A 1000 225 A 1125 250 A 1250 300 A 1500 350 A 1750 400 A 2000 1250 1500 1750 2000 2250 2500 3000 3500 4000 LA36125 LA36150 LA36175 LA36200 LA36225 LA36250 LA36300 LA36350 LA36400 4944. 4944. 4944. 4944. 4944. 4944. 4944. 4944. 4944. LH36125 LH36150 LH36175 LH36200 LH36225 LH36250 LH36300 LH36350 LH36400 8145. 8145. 8145. 8145. 8145. 8145. 8145. 8145. 8145. 400 A LI 2- and 3-pole 7.5 in (190 mm) Mounting Height AC Magnetic Trip Settings Terminal Wire Range AL400LA one #1 AWG–600 kcmil or two #1 AWG–250 kcmil AL or Cu AL400LA one #1 AWG–600 kcmil or two #1 AWG–250 kcmil AL or Cu Table 9.131: L-frame—600 A, Thermal-magnetic (600 Vac)c Ampere Rating LC 2- and 3-pole 7.5 in (190 mm) Mounting Height AC Magnetic Trip Settings Low 2-pole, 600 Vac b 300 A 1500 350 A 1750 400 A 2000 450 A 2250 500 A 2500 600 A 3000 3-pole, 600 Vac 300 A 1500 350 A 1750 400 A 2000 450 A 2250 500 A 2500 600 A 3000 b c Extra High Interrupting Catalog Number High LC26300( LC26350( LC26400( LC26450( LC26500( LC26600( 3200 4200 ) ) ) ) ) ) 8312. 8691. LC36300 LC36350 LC36400 LC36450 LC36500 LC36600 3200 4200 Current Limiting $ Price 9234. 9657. Catalog Number LI26300( LI26350( LI26400( LI26450( LI26500( LI26600( LI36300 LI36350 LI36400 LI36450 LI36500 LI36600 $ Price ) ) ) ) ) ) Terminal Wire Range 9563. AL600LI5 two #4/0 AWG–500 kcmil AL or Cu 13949. 10673. AL600LI5 two #4/0 AWG–500 kcmil AL or Cu 15498. 2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See Digest page 9-24. Type LC and LI circuit breakers are NOT recommended for use on single-motor branch circuits. L-frame acccessories. . . . . . . . . starting on Supplemental Digest page 3-24 L-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54 L-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-53 Table 9.132: Interrupt Ratings (kA) 240 V 480 V 600 V 9-28 LA LH LC LI 42 30 22 65 35 25 100 65 35 200 200 100 DE2 Discount Schedule © 2012 Schneider Electric All Rights Reserved Circuit Breakers L- and PowerPact M-frame for I-Line™ Panelboards and Switchboards Class 612, 661 www.schneider-electric.us Table 9.133: L-frame 600 A Circuit Breakers with Lugs and Factory-Sealed Electronic Trip Units Suitable for Reverse Connectiona Interrupting Rating (2nd Letter of Catalog Number) Electronic Trip Unit Trip Function Unit Sensor Rating Jc G Catalog Numberb Lc Rc Terminal $ Price 80% 100% 80% 100% 80% 100% 80% 100% 80% 100% 600 Vac, 53/60 Hz, 3P 250 A L( )A36250U31X 5122. 5943. 5376. 6240. 8773. 10214. 10213. 11899. 11745. 13745. 400 A 600 A L( )A36400U31X L( )A36600U31X 5122. 7404. 5943. — 5376. 7779. 6240. — 8773. 10836. 10214. — 10213. 12132. 11899. — 11745. 13952. 13745. AL600LF52K3f — 250 A 3.3Sd 400 A 600 A L( )A36250U33X 5686. 6506. 5969. 6833. 9366. 10808. 10806. 12493. 12427. 14449. L( )A36400U33X L( )A36600U33X 5686. 7968. 6506. — 5969. 8372. 6833. — 9366. 11429. 10808. — 10806. 12725. 12493. — 12427. 14634. 14449. — 5.3A 400 A 600 A L( )A36400U43X L( )A36600U43X 6548. 8830. 7368. — 6877. 9279. 7740. — 10274. 12336. 11715. — 11714. 13632. 13400. — 13471. 15677. 15523. — LSI 5.3E 400 A 600 A L( )A36400U53X L( )A36600U53X 7495. 9778. 8316. — 7874. 10277. 8738. — 11271. 13334. 12713. — 12711. 14630. 14398. — 14618. 16825. 16705. AL600LF52K3f — Micrologic Ammeter LSIG 6.3A 400 A 600 A L( )A36400U44X L( )A36600U44X 8444. 10726. 9264. — 8873. 11275. 9736. — 12270. 14332. 13711. — 13710. 15628. 15396. — 15767. 17972. 17887. — Micrologic Energy LSIG 6.3E 400 A 600 A L( )A36400U54X L( )A36600U54X 9392. 11674. 10212. — 9870. 12273. 10734. — 13267. 15329. 14709. — 14707. 16626. 16394. — 16913. 19120. 19069. — LI Micrologic Standard LSI Micrologic Ammeter LSI Micrologic Energy Interrupt Ratings (kA) G J Lh 65 100 125 480 V 35 65 100 600 V i 18 25 25 240 V h AL400L61K3e L interrupting rating is not available in M-frame. 600 V interrupt ratings not available for D-frame. Table 9.134: PowerPact M-frame: with ET1.0 Factory – sealed trip unit (not field adjustable)—800 A j Ampere Rating 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 3-pole, 600 Vac, 50/60 Hz i AL400L61K3e See Supplemental Digest page 3-4 for circuit breakers with field-interchangeable trip units. For 100% rated circuit breakers (250 A and 400 A only), add a “C” in the 9th character place (for example, LRA36400CU31X). Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting. 3P circuit breakers with this trip unit can be used for 2P applications. AL400L61K3 terminal wire ranges are (1) 2 AWG–600 kcmil Cu or (1) 2 AWG–500 kcmil Al. AL600LFS52K3 terminal wire range is (2) 3/0 –500 kcmil. For applications requiring communications, see Digest page 7-43. 2-pole, 600 Vac, 50/60 Hz a b c d e f g 3.3d 9 Micrologic Standard j k l Adjustable Instantaneous Trip Range k Low High 600 3000 700 3500 800 4000 900 4500 1000 5000 1200 6000 1400 7000 1600 8000 600 3000 700 3500 800 4000 900 4500 1000 5000 1200 6000 1400 7000 1600 8000 G Interrupting Catalog Number l $ Price MGA26300( ) MGA26350( ) MGA26400( ) 6633. MGA26450( ) MGA26500( ) MGA26600( ) MGA26700( ) 8370. MGA26800( ) MGA36300 MGA36350 MGA36400 8168. MGA36450 MGA36500 MGA36600 MGA36700 10608. MGA36800 J Interrupting Catalog Number l MJA26300( ) MJA26350( ) MJA26400( ) MJA26450( ) MJA26500( ) MJA26600( ) MJA26700( ) MJA26800( ) MJA36300 MJA36350 MJA36400 MJA36450 MJA36500 MJA36600 MJA36700 MJA36800 Terminal Wire Range $ Price 8253. 3–3/0 through 500 kcmil Al or Cu 10104. 9929. 3–3/0 through 500 kcmil Al or Cu 12630. The ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the long-time trip point setting. It is considered an electronic equivalent of a thermal-magnet circuit breaker. UL magnetic trip setting tolerances are ±10% from the nominal values shown. Fill in parentheses with the following phase connection options: (2) for AC and (5) for CA. L-frame accessories . . . . . . . . . .starting on Supplemental Digest page 3-24 L-frame dimensions . . . . . . . . . . . . . . . . . . . . . . starting on Digest page 7-54 L-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-53 M-frame accessories. . . . . . . . . . . . . . . . . . . . . . starting on Digest page 7-36 M-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55 M-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39 Table 9.135: Automatic Molded Case Switches—600 Vac, 50/60 Hz Ampere Rating 600 A 800 A 1000 A 1200 A m n 2-pole Catalog Number n $ Price PJA26000S60( ) 6675. PJA26000S80( ) 7347. PJA26000S10( ) 8088. PJA26000S12( ) 10895. 3-pole Catalog Number PJA36000S60 PJA36000S80 PJA36000S10 PJA36000S12 $ Price 7263. 7938. 8676. 11766. Withstand Rating m 240 Vac 480 Vac 600 Vac 100 65 25 100 65 25 100 65 25 100 65 25 Trip Point Amperes AC 10000 10000 10000 10000 Terminal Wire Range 3–3/0 through 500 kcmil Al or Cu 4–3/0 through 500 kcmil Al or Cu The withstand rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a circuit breaker with an equal ampere rating. Fill in parentheses with the following phase connection options: (2) for AC or (5) for CA. Table 9.136: PowerPact P- and R-frame Interrupt Ratings Voltage 240 Vac 480 Vac 600 Vac G 65 kA 35 kA 18 kA P-frame Interrupt Rating J K 100 kA 65 kA 65 kA 50 kA 25 kA 50 kA P- and R-frame accessories . . . . . . . . . . . . . . . starting on Digest page 7-36 P- and R-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55 © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule L 125 kA 100 kA 25 kA G 65 kA 35 kA 18 kA R-frame Interrupt Rating J K 100 kA 65 kA 65 kA 65 kA 25 kA 65 kA PANELBOARDS Type D L 125 kA 100 kA 50 kA P- and R-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39 9-29 Circuit Breakers PowerPact P- and R-frame for I-Line™ Panelboards and Switchboards Class 612 / Refer to Catalog 0612CT0101 www.schneider-electric.us 9 Table 9.137: PowerPact P-frame 1200 A (600 Vac, 50/60 Hz) 3P Circuit Breaker with Electronic Trip Unit Electronic Trip Unit Type Function Code PANELBOARDS Basic Electronic Fixed long-time, Trip Unit Adjustable ET1.0I (Not Interchangeable) Instantaneous LI 3.0 Micrologic Interchangeable Standard Trip Unit LSI LI Micrologic Interchangeable Ammeter Trip Unit LSI LSIG LSI 5.0 3.0A 5.0A 6.0A 5.0P Micrologic Interchangeable Power Trip Unit LSIG LSI 6.0P 5.0H Micrologic Interchangeable Harmonic Trip Unit LSIG 6.0H Sensor Rating Cat. No.ab 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A 250 A 400 A 600 A 800 A 1000 A 1200 A P( )A36060 P( )A36080 P( )A36100 P( )A36120 P( )A36025(C)U31A P( )A36040(C)U31A P( )A36060(C)U31A P( )A36080(C)U31A P( )A36100U31A P( )A36120U31A P( )A36025(C)U33A P( )A36040(C)U33A P( )A36060(C)U33A P( )A36080(C)U33A P( )A36100U33A P( )A36120U33A P( )A36025(C)U41A P( )A36040(C)U41A P( )A36060(C)U41A P( )A36080(C)U41A P( )A36100U41A P( )A36120U41A P( )A36025(C)U43A P( )A36040(C)U43A P( )A36060(C)U43A P( )A36080(C)U43A P( )A36100U43A P( )A36120U43A P( )A36025(C)U44A P( )A36040(C)U44A P( )A36060(C)U44A P( )A36080(C)U44A P( )A36100U44A P( )A36120U44A P( )A36025(C)U63AE1 P( )A36040(C)U63AE1 P( )A36060(C)U63AE1 P( )A36080(C)U63AE1 P( )A36100U63AE1 P( )A36120U63AE1 P( )A36025(C)U64AE1 P( )A36040(C)U64AE1 P( )A36060(C)U64AE1 P( )A36080(C)U64AE1 P( )A36100U64AE1 P( )A36120U64AE1 P( )A36025(C)U73AE1 P( )A36040(C)U73AE1 P( )A36060(C)U73AE1 P( )A36080(C)U73AE1 P( )A36100U73AE1 P( )A36120U73AE1 P( )A36025(C)U74AE1 P( )A36040(C)U74AE1 P( )A36060(C)U74AE1 P( )A36080(C)U74AE1 P( )A36100U74AE1 P( )A36120U74AE1 G Interrupting a 80% 100% Rated Rated b $ Price J Interrupting a K Interrupting a 80% 100% 80% 100% Rated Rated b Rated Rated b L Interrupting ac 80% 100% Rated Rated b Terminal Wire Range (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 14603. — 15480. — 15480. — 16359. — 20003. — 21207. — 21207. — 22410. — 15390. 22479. 16268. 23897. 16268. 23897. 17147. 25314. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 20790. — 21995. — 21995. — 23198. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 15729. 22794. 16608. 24231. 16608. 24231. 17487. 25668. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 21131. — 22334. — 22334. — 23538. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 16242. 23270. 17121. 24737. 17121. 24737. 17999. 26204. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 21642. — 22845. — 22845. — 24051. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 17739. 24659. 18618. 26214. 18618. 26214. 19497. 27770. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 23141. — 24345. — 24345. — 25548. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 19607. 26393. 20486. 28058. 20486. 28058. 21365. 29721. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 25008. — 26211. — 26211. — 27416. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 22151. 28754. 23030. 30566. 23030. 30566 23909. 32379. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 27552. — 28757. — 28757. — 29960. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 23234. 29757. 24111. 31634. 24111. 31634. 24990. 33510. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 28634. — 29838. — 29838. — 31041. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 26234. 32541. 27113. 34593. 27113. 34593. 27992. 36645 (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 31634. — 32837. — 32837. — 34043. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K 27315. 33545. 28194. 35661. 28194. 35661. 29073. 37776. (3) 3/0 AWG–500 kcmil Al or Cu AL800M23K 32717. — 33921. — 33921. — 35124. — (4) 3/0 AWG–500 kcmil Al or Cu AL1200P24K Table 9.138: PowerPact R-frame 1200 A (600 Vac, 50/60 Hz) 3P Circuit Breaker with Electronic Trip Unit Electronic Trip Unit Type Function Code Sensor Rating G Interruptingac 80% 100% Rated Rated Cat. No. $ Price J Interruptingac K Interruptingac L Interruptingacd 80% 100% 80% 100% 80% 100% Rated Rated Rated Rated Rated Rated Terminal Wire Range Basic Electronic Trip Unit (Not Interchangeable) Fixed Long-Time, R( )A36120 27080. — 28777. — 28777. — 30533. — Adjustable Instantaneous ET1.01 1200 A 1000 A R( )A36100CU31A LI 3.0 — 33945. — 36111. — 36111. — 38418. Micrologic 1200 A R( )A36120CU31A Interchangeable Standard 1000 A R( )A36100CU33A Trip Unit LSI 5.0 — 34401. — 36599. — 36599. — 38934. 1200 A R( )A36120CU33A 1000 A R( )A36100CU41A LI 3.0A — 35141. — 37383. — 37383. — 39770. 1200 A R( )A36120CU41A Micrologic 1000 A R( )A36100CU43A Interchangeable Ammeter LSI 5.0A — 36581. — 38916. — 38916. — 41400. AL1200R53K 1200 A R( )A36120CU43A Trip Unit (4) 3/0-600 kcmil 1000 A R( )A36100CU44A Al or Cu LSI 6.0A — 38378. — 40829. — 40829. — 43434. 1200 A R( )A36120CU44A 1000 A R( )A36100CU63AE1 LSI 5.0P — 40826. — 43431. — 43431. — 46205. Micrologic 1200 A R( )A36120CU63AE1 Interchangeable Power 1000 A R( )A36100CU64AE1 Trip Unit LSIG 6.0P — 41867. — 44540. — 44540. — 47382. 1200 A R( )A36120CU64AE1 1000 A R( )A36100CU73AE1 LSI 5.0H — 44754. — 47610. — 47610. — 50649. Micrologic 1200 A R( )A36120CU73AE1 Interchangeable Harmonic 1000 A R( )A36100CU74AE1 Trip Unit LSIG 6.0H — 45795. — 48719. — 48719. — 51827. 1200 A R( )A36120CU74AE1 a To complete the catalog number, replace the blank ( ) with the appropriate interrupt rating (G, J, K, or L). b For 100% rated circuit breakers add a “C” in the 9th character place. For example, the catalog number for a 100% standard-type trip unit with LI trip functions at 250 A would be PGA36025CU31A. c The L interrupt rating is supplied in 480 V only. Change the 5th character (voltage rating) from a 6 (600 V) to a 4 (480 V); for example, PLA34025U31A. d See Table 9.136 on Digest page 9-29 for interrupt ratings. P- and R-frame accessories. . . . . . . . . . . . . . . . starting on Digest page 7-36 P- and R-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39 P- and R-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55 P- and R-frame alternate rating plugs . . . . . . . . . . . . . . . . . Digest page 7-45 P- and R-frame trip unit options . . . . . . . . . . . . . . . . . . . . . Digest page 7-44 9-30 DE2 Discount Schedule © 2012 Schneider Electric All Rights Reserved I-Line™ Factory Assembled Panelboards 600 Vac, 250 Vdc Class 2110 / Refer To Catalog 2110CT9701 www.schneider-electric.us Panel Type 225 A 1356. — — — — HCN HCM HCP-SU HCP HCR-U a Table 9.140: Standard Solid Neutral Main Lugs 600 A 2276. 2276. 2990. 2456. — 400 A 1866. 1866. — — — 800 A — 2512. 3600. 3056. — Ampere Rating 100/225 A 400 A 600 A 800 A 1200 A 1200 A — — — 3968. 4602. $ Price 294. 384. 544. 764. 1366. PANELBOARDS Table 9.139: Base $ Price—Main Lugs a When required, add the $ Price of a solid neutral from Table 9.140. Table 9.141: Base $ Price—Main Circuit Breaker b Main Circuit Breaker 2 3 2 3 HCN HCM 150 A FI c HD c HG c 4642. 3360. 3860. 5864. 3770. 4210. — 3360. 3860. — 3770. 4210. FA 2100. 2418. — — FH 2100. 2958. — — JD JG JJ 3956. 4440. 3956. 4440. — — 4146. 5550. 4146. 5550. — — 7126. 7466. 7126. 7466. — — HJ c HL c 4540. 5550. 4890. 5900. 4540. 5550. 4890. 5900. 9 100 A No. Panel Type Poles 225 A No. Panel Type Poles HCN HCM HCP, HCP-SU 2 3 2 3 2 3 400 A LD KI c JL LG LJ LL 600 A LA Electronic 100% — — — — — — — — 7356. 8356. — — 8676. 10148. — — 7356. 8356. — — 8676. 10148. — — — — 11865. 12470. 14795. 15940. — — LH LC c LD LI c LG LJ LL LC c Electronic 80% — — — — — — — — LI c MG 6132. 9126. — — — — — — — 7136. 10666 — — — — — — — 6132. 9126. — — — — — — 8880. 7136. 10666. — — — — — — 10770. — — 10366. 11610. 11176. 16504. 8880. 15425. 16215. 19235. 20725. — — 11888. 13354. 12678. 18090. 10770. MJ — — 11260. 13400. 11260. 13400. 800 A d No. Panel Type Poles HCN HCM HCP, HCP-SU 2 3 2 3 2 3 MG — — 11846. 14302. 11846. 14302. PL b MJ PG c PJ c PL c PGC c PJC c PLC c Micrologic™ 80% Micrologic 100% — — — — — — — — — — — — — — — — 14778. — — — — — — — 17456. — — — — — — — 14778. 19346. 15830. 16830. 21090. 16542. 18510. 24250. 17456. 23416. 18312. 20280. 24540. 20144. 22300. 28220. 1200 A cde No. Panel Type Poles HCP, HCP-SU HCR-U b c d e 2 3 2 3 PG PJ PL 22542. 24568. 22542. 24568. 24336. 26560. 24336. 26560. 26648. 29128. 26648. 29128. PG PJ PL Micrologic 80% 22380. 24980. 27980. 28710. 31310. 35570. 22380. 24980. 27980. 28710. 31310. 35570. RGC RJC RLC Micrologic 100% 24618. 24478. 32178. 31582. 34442. 40906. 24618. 24478. 32178. 31582. 34442. 40906. When required, add the $ Price of a solid neutral from Table 9.140. Standard construction back-fed main. PG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. The “C” suffix denotes a 100% rating. For 1200 A frame thermal magnetic circut breaker with 600 kcmil lugs, select an R-frame Thermal Magnetic circuit breaker in the Product Selector. Table 9.142: Electronic Trip Units for H-frame Circuit Breakers LI (3.0) LSI (5.0) LSIG (6.0) f Standard $ Price Standard 549. — Ammeter $ Price — 2550. 4577. Table 9.144: Electronic Trip Units (L-, P-, and R-frame Circuit Breakers) Energy $ Price — 3485. 5979. Table 9.143: Electronic Trip Units for J-frame Circuit Breakers LI (3.0) LSI (5.0) LSIG (6.0) f Standard $ Price Standard 785. — Ammeter $ Price — 3643. 6538. Energy $ Price — 4978. 8542. $ Price LI (3.0) LSI (5.0) LSIG (6.0) f Standard Standard 1670. — Ammeter Energy Note: — — 4670. 7659. 9340. 13777. Power — 21600. 31000. Harmonic — 32330. 37000. f When adding G, requires current transformers and a box extension and is available factory assembled only. Note: Energy trip unit available for L-frame circuit breakers only. PowerPact circuit breakers come with a standard LI trip unit. Use the above $ Price adder for increase in trip functionality. See Digest page 7-43 for L- frame trip unit descriptions. See Digest page 7-44 for P- and R- frame trip unit descriptions. Table 9.145: I-Line 200% Rated Neutral—Standard Terminal Configuration g Branch Space Panel Type Ampacity Type Neutral Terminals Quantity and Size In. mm Main Branch (35) 350 kcmil, (9)#14-1/0, (17)#14-#4 HCM 600 A 600 A (MG, MJ) 800 A 800 A (MG, MJ) MLO M/B MLO M/B 72 72 72 72 1829 1829 1829 1829 (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil (8) 750 kcmil HCR-Uh 1200A M/B, MLO 108 2743 (8) 750 kcmil 600A M/B, MLO 63 1600 (8) 750 kcmil HCP HCP-SUi g h i 800A M/B, MLO 99 2515 (8) 750 kcmil 800A M/B, MLO 54 1371 (8) 750 kcmil (8) 600 kcmil, (15) 350 kcmil (9) #14-1/0, (17)#14-#4 (35) 350 kcmil, (9)#14-1/0, (17)#14-#4 (35) 350 kcmil, (9)#14-1/0, (17)#14-#4 (8) 750 kcmil, (21) 350 kcmil, (9) #14-1/0, (17) #14-#4 Type 1 Enclosure H In. 91 91 91 91 W mm 2311 2311 2311 2311 In. 32 32 32 32 D mm 813 813 813 813 In. 8.25 9.50 8.25 9.50 mm 210 241 210 241 86 2184 44 1118 9.50 241 68 1727 42 1067 9.50 241 86 2184 42 1067 9.50 241 86 2184 26 660 9.5 241 Available in Type 1 enclosure only; for pricing, see Digest page 9-34. 6 in. enclosure extension is required for HCRU I-Line panelboard. 9 in. enclosure extension is required for HCP-SU I-Line panelboard. © 2012 Schneider Electric All Rights Reserved PE1 Discount Schedule 9-31 I-Line™ Factory Assembled Panelboards 600 Vac, 250 Vdc Class 2110 / Refer to Catalog 2110CT9701 www.schneider-electric.us 9 Table 9.146: Branch Circuit Breakers—Thermal Magnetic Circuit Breakers a (See Digest pages 7-4 through 7-8 for interrupt rating, voltage ratings, Fed. Specs, etc.) PANELBOARDS Circuit Breaker Ampere Rating Circuit Breaker 15–60 A 70–100 A 15–60 A 70–100 A 15–60 A 70–100 A 20–100 A 15–60 A 70–100 A 110–150 A 15–60 A 70–100 A 110–150 A 15–60 A 70–100 A 110–150 A 15–60 A 70–100 A 110–150 A 70–225 A 70–225 A 70–225 A 70–225 A 150–225 A 250 A 150–225 A 250 A 150–225 A 250 A 150–225 A 250 A 150–225 A 250 A 300–400 A 300–400 A 300–400 A 450–600 A 300–400 A 450–600 A 300–600 A 700–800 A 300–600 A 700–800 A 600–800 A 600–1200 A 600–1200 A 1000–1200 A 250–400 A 450–600 A 700–800 A FA (FY-1P) FA 1000–1200 A a b c d e 9-32 FH FJd FI HD HG HJ HL QB QD QG QJ JD JG JJ JL KI LA LH LC LI MG MJ PL PG PJ /PK PL PLC (100%) e RG (80%) e RJ (80%) e RL (80%) e 3-pole e 240 V 720. 832. 1100. 1300. 1300. 1500. — — — — — — — — — — — — — 1696. 2208. 2870. 3070. — — — — — — — — — — — — 5460. — — — — — — — — — — — — — — — — — 480 Vac 250 Vdc 882. 1142. b — — 2080. 2470. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 20360. — — 24526. 16940. 22620. 24440. — — — 600 V 1006. 1218. 1442. 1940. — — 4254. 1350. 1570. 2710. 1710. 2198. 3310. 2380. 2700. 4500. 3910. 4054. 5530. — — — — 2820. 3800. 3990. 4180. 6110. 6500. 7320. 8900. 7972. 9268. 4916. 5312. 10156. 10422. 11622. 15834. 8152. 10600. 10126. 13306. — 19966. 21960. — — — — 24460. 26710. 32580. 2-pole e Space Only 98. 98. H (In.) 4.5 4.5 98. 4.5 98. 3 98. 4.5 98. 4.5 98. 4.5 98. 4.5 98. 4.5 98. 98. 98. 98. 4.5 4.5 4.5 4.5 98. 4.5 98. 4.5 98. 4.5 98. 4.5 98. 252. 6 7.5 456. 7.5 662. 9 662. 9 662. 662. 662. 662. 9 9 9 9 662. 9 662. 15 520. 632. 1050. 1250. 1250. 1450. — — — — — — — — — — — — — 560. 1300. b 2800. 3000. — 3600. 4600. 3900. 4000. 4300. 4300. — — — — 4550. — — — — — — — — — — — — — — — — — 4.5 456. 240 Vac 480 Vac 250 Vdc 708. 956. — — 1660. 1980. — — — — — — — — — — — — — — — — — — — — — 5434. 6672. 5434. 6672. — — — — — — — — — — — — 16290. — — 22046. 13550. 18100. 19560. — — — 1-pole e 600 Vac 786. 964. 1218. 1620. — — 3466. 1150. 1370. 2370. 1352. 1508. 3110. 2002. 2364. 3980. 3250. 3402. 4600. — — — — 2600. 3430. 2790. 3620. 5770. 6450. 6000. 6800. 6216. 7262. 3980. 4500. 8634. 8920. 9878. 14248. 6322. 8180. 8536. 10944. — 17940. 19724. — — — — 24460. 26710. 32580. b b b b b Space Only H (In.) 82. 3 98. 3 98. 3 98. 4.5 98. 3 98. 3 98. 4.5 98. 4.5 82. 82. 82. 82. 3 3 3 3 98. 4.5 98. 4.5 98. 4.5 98. 4.5 98. 4.5 252. 6 456. 7.5 456. 7.5 662. 9 662. 9 662. 9 662. 9 662. 9 662. 9 662. 15 120 V — 354. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 277 V — 384. — — 664. 832. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 277 Vac 125 Vdc 270. c 384. c 518. 650. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Space Only 72. 72. 72. 72. 72. 72. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — H (In.) 1.5 1.5 1.5 1.5 1.5 1.5 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — See Digest pages 7-4 through 7-8 for additional dc ratings. ac only. FA, 1P. 480Y/277 Volt rated circuit breaker—Do not use on 480 Volt 3Ø3W Delta systems. See Table 9.144 on Digest page 9-31 for P- and R frame Micrologic trip unit price adders. PE1 Discount Schedule © 2012 Schneider Electric All Rights Reserved I-Line™ Factory Assembled Panelboards 600 Vac, 250 Vdc Class 2110 / Refer to Catalog 2110CT9701 www.schneider-electric.us Table 9.147: Branch Circuit Breakers—Electronic Trip Circuit Breakers a (See Digest pages 7-4 through 7-8 for interrupt rating, voltage ratings, Fed. Specs, etc.) 1000–1200 A a b c d e HD (80%) b JD (80%) c HG (80%) b JG (80%) c HJ (80%) b JJ (80%) c HL (80%) b JL (80%) c LD (80%) d LG (80%) d LJ (80%) d LL (80%) d LDC (100%) d LLC (100%) d LGC (100%) d LJC (100%) d DG (100%) e DG (80%) e DJ (100%) e DJ (80%) e DL (100%) e DL (80%) e PG (80%) d PJ/PK (80%) d PL (80%) d PGC (100%) d PJC/PKC (100%) d PLC (100%) d RG (100%) d RJ (100%) d RL (100%) d 2-pole d 3-poled 240 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 480 Vac 250 Vdc — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 5687. 8954. 9118. 12385. 10573. 13839. — — — — — — — — 15400. 20570. 22220. 29850. — — — — — — 16940. 22620. 24440. — — — 600 V 1790. 2102. 3756. 4013. 2110. 2380. 4848. 5082. 2703. 2898. 6895. 7231. 4027. 4263. 8943. 9381. 5378. 5378. 7775. 5645. 5645. 8167. 9212. 9212. 11378. 10724. 10724. 12738. 6991. 6991. 13941. 13941. 7338. 7338. 11975. 11975. — — — — — — 8900. 13310. 14730. 21240. 10400. 15570. 17220. 24850. — — — — 9790. 14642. 16200. 11960. 17900. 19800. — — — 29317. 32159. 39389. Space Only 98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 98. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. 252. H 240 Vac 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 662. 9 662. 9 662. 9 662. 9 662. 9 662. 9 662. 15 480 Vac 250 Vdc — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 4550. 7163. 7295. 9908. 8458. 11071. — — — — — — — — 12320. 16450. 17780. 23880. — — — — — — 13550. 18100. 19560. — — — 600 Vac — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 7120. 10648. 12402. 16992. 9240. 12450. 13780. 19880. — — — — 7832. 11714. 13642. 9570. 14330. 15840. — — — 29317. 32159. 39389. 1-pole d Space Only — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 252. 252. 252. 252. 252. 252. H 120 V 277 V — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 6 6 6 6 6 6 662. 9 662. 9 662. 9 662. 9 662. 9 662. 9 662. 15 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 277 Vac 125 Vdc — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Space Only — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — H — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — See Digest pages 7-4 through 7-8 for additional dc ratings. See Table 9.142 on Digest page 9-31 for H-frame electronic trip unit price adders. See Table 9.143 on Digest page 9-31 for J-frame electronic trip unit price adders. See Table 9.144 on Digest page 9-31 for L-, P-, and R-frame electronic trip unit price adders. See the Supplemental Digest for D-frame electronic trip unit price adders. © 2012 Schneider Electric All Rights Reserved PE1 Discount Schedule 9-33 PANELBOARDS 15–60 A 35–100 A 50–150 A 70–250 A 15–60 A 35–100 A 50–150 A 70–250 A 15–60 A 35–100 A 50–150 A 70–250 A 15–60 A 35–100 A 50–150 A 70–250 A 70–250 A 125–400 A 200–600 A 70–250 A 125–400 A 200–600 A 70–250 A 125–400 A 200–600 A 70–250 A 125–400 A 200–600 A 70–250 A 125–400 A 70–250 A 125–400 A 70–250 A 125–400 A 70–250 A 125–400 A 60–400 A 600 A 60–400 A 600 A 60–400 A 600 A 250–400 A 450–600 A 700–800 A 1000–1200 A 250–400 A 450–600 A 700–800 A 1000–1200 A 250–400 A 450–600 A 700–800 A 1000–1200 A 250–400 A 450–600 A 700–800 A 250–400 A 450–600 A 700–800 A 250–400 A 450–600 A 700–800 A Circuit Breaker 9 Circuit Breaker Ampere Rating I-Line™ Factory Assembled Panelboards Common Feature Pricing Class 2110 / Refer to Catalog 2110CT9701 www.schneider-electric.us 9 Table 9.148: QO Plug-On Branch Circuit Breakers Table 9.156: Door-in-Door Trim $ Price Transition Charge per 6 QO one-pole spaces (H=4.5 in. per 6 one-pole spaces) QO Branch circuit breakers 328. See Digest page 7-10 Door-in-Door Trim Trim has piano hinge down one side. Door opens by single latch; Entire trim opens by removing screws. Hinged Door-in-Door with Outer Door Lock Added $ Price Adder 646. 836. Table 9.157: Weatherproof or Dusttight Cabinets—Type 3R, 5, 12 PANELBOARDS Table 9.149: Sub-feed/Feed-through Lugs a Ampere Rating 225 A 400 A 600 A 800 A 1200 A a $ Price 368. 600. 858. 1490. 1890. Weatherproof or Dusttight Cabinets Maximum 26 in. wide box Maximum 28 in. wide box Maximum 32 in. wide box Maximum 42 in. wide box Maximum 44 in. wide box Table 9.158: Copper Mechanical Lugs 2 or 3-pole Branch Mounted; SL Kit used for both SFL and TFL. Main Lug Interiors Ampere Rating $ Price Equipment Ground Bar Copper Ground Bar b 180. 148. $ Price Additional Neutral Assembly b Main Circuit Breaker Interiors $ Price per Pole 70. 108. 148. 168. 196. 236. Table 9.150: Ground Bars Insulated/Isolated Ground Bar $ Price Adder 2156. 3312. 3312. 3312. 3312. 100/125 A 250 A 400 A 600 A 800 A 1200 A 70. 108. 148. 168. 196. 236. Add to equipment ground bar $ Price. Table 9.159: Copper Compression Lugs Table 9.151: Name Plates $ Price Standard white face/black letter laminated bakelite, 1 in. x 3.5 in., adhesive backed or screw mountable with screws in a bag assembly ($ Price includes engraving) 78. Table 9.152: Copper Bus Bars Ampere Rating 225 A 400 A 600 A 600 A 800-1200 A Type HCN, HCM HCN, HCM, HCP HCN HCM, HCP, HCR-U HCP, HCR-U $ Price 528. 720. 720. 1274. 1274. Type Copper Neutral Copper Neutral Copper Neutral Copper Neutral 70. 108. 148. 168. 316. — Table 9.160: Aluminum Compression Lugs VCEL Main Circuit Breaker Interiors c Main Lug Interiors Ampere Rating $ Price Per Pole 29.00 N/A 29.00 45.00 59.00 100.00 118.00 100 A 150 A 250 A 400 A 600 A 800 A 1200 A $ Price Adder 868. 894. 1108. 1352. 29.00 29.00 49.00 74.00 131.00 — — Note: Additional factory modifications. See Digest page 9-38. c Compression lugs are not available on LC, LI, LE, LX, and LXI circuit breakers. Table 9.154: 200% Rated Neutrals Ampere Rating 225 A 400 A 600 A 800 A 1200 A 225 A 400 A 600 A 800 A 1200 A Main Circuit Breaker Interiors $ Price per Pole 70. 108. 148. 168. 316. 836. 100/125 A 250 A 400 A 600 A 800 A 1200 A Table 9.153: Neutrals Ampere Rating 100–400 A 600 A 800 A 1200 A Main Lug Interiors Ampere Rating Type Aluminum Aluminum Aluminum Aluminum Aluminum Copper Copper Copper Copper Copper $ Price Adder 820. 940. 1340. 1350. 2020. 1210. 1300. 1980. 2500. 2900. Surgelogic™ SPD Surgelogic SPD unit in I-Line plug-on construction: An integrally mounted surge protection solution that mounts on to an I-Line Panelboard bus stack just like a J-Frame circuit breaker. Requires 13.5 in. of mounting height. Available as factory assembled and merchandised. For SPD unit pricing and information, see Digest pages 6-3 and 6-44. I-Line Plug-On Unit with Surgelogic SPD Table 9.155: Metal Directory Frame Metal Directory Frame Frame attached to trim (not available on four piece trim) $ Price Adder 140. Table 9.161: Surgelogic SPD Options Surgelogic SPD Options $ Price Standard Dry Contacts Remote Monitor 2588. Note: Requires HCM interior minimum. Table 9.162: Surgelogic Branch Mounted I-Line SPD—Model IMA Surge Current Rating kA Voltage 120/240 1P3W 208Y/120 3P4W 240/120 3P4W 480Y/277 3P4W 600Y/347 3P4W 9-34 100 kA HL 18908. 19750. 19750. 20602. — 120 kA FI 20416. 21260. 21260. 22110. 23000. HL 20088. 20984. 20984. 21898. — 160 kA FI 21692. 22588. 22588. 23492. 24438. PE1 HL 23634. 24688. 24688. 25752. — Discount Schedule 200 kA FI 25520. 26574. 26574. 27638. 28750. HL 29354. 30740. 30740. 32130. — 240 kA FI 30958. 32342 32342. 33734. 35198. HL 34534. 36164. 36164. 37800. — FI 36420. 38050. 38050. 39686. 41400. © 2012 Schneider Electric All Rights Reserved QMB Fusible Branch Switches For QMB/QMJ Panelboards and Switchboards Class 4620 / Refer to Catalog 4620CT9601 www.schneider-electric.us Table 9.163: QMB Branch Switch Units 2-pole, 240 Vac 30 A-30 A 4.5 30 A-Blank 4.5 60 A-60 A 4.5 60 A-Blank 4.5 100 A-100 A 6 100 A-Blank 6 200 A 9 15 400 A 9 600 A Catalog Number $ Price No. Kits Req’d. QMB221TW 608. 2 QMB221HWb 425. 1 QMB222TW 608. 1 QMB222HWb 425. QMB223TW 990. 1 QMB223HWb 695. QMB224W 1200. 1 QMB225W 3072. 1 QMB225WT3c 2981. — Use 3-pole devices for 2-pole application. 3-pole, 240 Vac 30 A-30 A 4.5 QMB321TW 827. 2 30 A-Blank 4.5 QMB321HWb 587. 1 60 A-60 A 4.5 QMB322TW 827. 1 60 A-Blank 4.5 QMB322HWb 587. 100 A-100 A 6 QMB323TW 1265. 1 100 A-Blank 6 QMB323HWb 879. 200 A 9 QMB324W 1673. 1 15 QMB325W 4277. 1 400 A 9 QMB325WT3 c 4143. — 15 QMB326W 6249. 1 600 A 15 QMB326WT3 c 6249. — 800 A 15 QMB327WT3c 12140. — 2-pole, 600 Vac, 250 Vdcd 30 A-30 A 4.5 QMB261TW 1050. 1 30 A-Blank 4.5 QMB261HWb 702. 60 A-60 A 6 QMB262TW 1050. 1 60 A-Blank 6 QMB262HWb 738. 100 A-100 A 7.5 QMB263TW 1536. 2 100 A-Blank 7.5 QMB263HWb 1083. 1 200 A 9 QMB264W 1791. 1 400 A Use 3-pole devices for 2-pole application. 600 Ae 3-pole, 600 Vacd 4.5 30 A-30 A 4.5 30 A-Blank 4.5 6 60 A-60 A 6 60 A-Blank 6 6 60 A-30 A 6 7.5 100 A-100 A 6 7.5 100 A-Blank 6 7.5 100 A-30 A 7.5 7.5 100 A-60 A 7.5 200 A 9 200 A-200 A 7.5 200 A-Blank 7.5 400 Af 15 400 A 9 400 Af 9 600 Aef 15 60 A0 15 800 Ag 15 a b c d e f g h i QMB361TW QMJ361T QMB361HWb QMB362TW QMJ362T QMB362HWb 1241. 1293. 861. 1241. 1293. 861. QMB362T21W 1241. QMB363TW QMJ363T QMB363HWb QMJ363Hb 1961. 2013. 1373. 1424. QMB363T31W 1961. QMB363T32W 1961. QMB364W 2306. QMJ364T 4712. QMJ364Hb 2357. QMB365W 5445. QMJ365 5561. QMB365WT6h 5276. QMB366W 6735. QMJ366 6704. QMB367W 12140. 1 — 1 1 — 1 Electrical Interlock Kit Horsepower Ratingsi 240 Vac Catalog Number $ Price Catalog Number a $ Price Std. 480 Vac Max. 1Ø 3Ø 1Ø 3Ø Std. 600 Vac Max. Std. 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 5 5 10 10 20 20 40 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — QMB100R 95.00 QMB610EK(1 or 2) 357. 7.5 15 15 30 HRK1020 QMB4060R — 47.70 QMB200EK(1 or 2) 111.00 — — — 357. — — — — — — — — — 25 — — — — 15 — — — — 60 — — — — 3 3 7.5 7.5 15 15 25 50 50 75 75 75 — — — — — — — — — — — — 7.5 7.5 15 15 30 30 60 125 — 150 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3 5 7.5 15 3 5 15 20 30 10 25.50 QMB300EK(1 or 2) 357. 1.5 3 3 7.5 QMB36R 48.90 QMB300EK(1 or 2) 357. 3 7.5 10 15 — QMB100R 95.00 QMB610EK(1 or 2) 357. HRK1020 QMB4060R — QMB4060R — — 47.70 QMB200EK(1 or 2) 111.00 — — — 111.00 — — — — — 357. — — — — — — — — — — — — — — — — — QMB36R 48.90 QMB300EK(1 or 2) 357. 1.5 QMB60R 48.90 357. 3 HRK30 QMB36R 25.50 357. QMB300EK(1 or 2) 48.90 357. HRK1020 47.70 357. 7.5 HRK1020 47.70 QMB200EK(1 or 2) 357. 15 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3 — 3 7.5 — 7.5 — — 15 — 15 — — — — — 25 25 — — 50 — — 75 — — — — — — — — — — — — — — — — — — — — — — — — — — 7.5 — 7.5 15 — 15 — — 30 — 30 — — — — — 60 60 — — 125 — — 150 — — — — — — — — — — — — — — — — — — — — — — — — — — 5 — 5 15 — 15 — — 25 — 25 — — — — — 50 50 — 100 100 — 150 — 150 — — — — — — — — — — — — — — — — — — — — — — — — — 15 — 15 30 — 30 — — 60 — 60 — — — — — 125 125 — 250 250 — 400 — 400 — — — — — — — — — — — — — — — — — — — — — — — — — QMB36R — QMB36R QMB60R — QMB60R and 1 ea. QMB60R QMB36R 2 HRK1020 — — 1 HRK1020 — — and 1 ea. HRK1020 QMB36R QMB610EK(1 or 2) 48.90 — 48.90 48.90 — 48.90 48.90 — 47.70 — 47.70 — 47.70 48.90 and 47.70 1 ea. HRK1020 QMB60R 48.90 1 HRK1020 47.70 — — — — — — 1 QMB4060R 111.00 — — — — — — 1 QMB4060R 111.00 — — — — — — — QMB300EK(1 or 2) 357. QMB300EK(1 or 2) 357. QMB610EK(1 or 2) 357. QMB610EK(1 or 2) 357. QMB610EK(1 or 2) 357. QMB610EK(1 or 2) 357. QMB610EK(1 or 2) 357. QMB610EK(1 or 2) 357. QMB610EK(1 or 2) 357. QMB200EK(1 or 2) 357. QMB610EK(1 or 2) 357. — QMB200EK(1 or 2) — — — — — 357. — — — 10 25 30 60 15 — — — — — — — — 25 50 50 125 30 — — — — — — — 3 10 15 250 Vdc 3Ø — — — — — — — — — — — HRK30 Max. 1Ø 50 — — — — — — — — — — — 7.5 — 7.5 15 — 15 — — 30 — 30 — — — — — 60 60 — 125 125 — 250 — — — — — — — — — — — — — — — — — — — — — — — — — 20 20 20 50 — 50 — — 75 — 75 — — — — — 150 150 — 350 350 — 500 — 500 — 5 — — 10 — — — — 20 — 20 — — — — — 40 — 50 50 — — — — 250 10 25 40 5 10 20 40 “1’’ indicates one normally open and one normally closed contact. “2’’ indicates two normally open and two normally closed contacts. Blank units cannot be modified to accept a switch interior. Use 300 Vac Class T fuses only. Class J fuse provisions—to field modify switch, move load side fuse base to position indicated in switch. Not available on 100-30, 100-60, or 800 A switch units. To adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB600T6, $ Price 194. (Use T6 fuses with standard horsepower ratings only). 250 Vdc rating. To adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB800T6, $ Price 467. (Use T6 fuses with standard horsepower ratings only). Use 600 Vac Class T fuses only. Horsepower rating applicable to 480Y/277 V system only. Note: See the Supplemental Digest for merchandised motor starter units, QMB RTI panelboards, and replacement switches for Series 1–4 and D2 QMB panelboards. Note: For series E1 and E2, QMJ switches may be used in 400 A–1200 A interiors in a NEMA 1 without door only. QMJ switches cannot be used in series E1 and E2, 225 A panelboards. QMJ switches cannot be used in NEMA 1 with door or any NEMA 3R/12 enclosure. © 2012 Schneider Electric All Rights Reserved PE1A Discount Schedule 9-35 PANELBOARDS Unit Height (In.) 9 Class R Fuse Kits Unit Ampere Rating QMB Factory Assembled Panelboards Fusible—600 Vac, 250 Vdc Class 4620 / Refer to Catalog 4620CT9601 www.schneider-electric.us 9 Table 9.164: Base $ Price Main Switch a Main Lugs Maximum Mounting Space (In.) — — 60 60 60 60 45 Mains Rating (Amperes) PANELBOARDS — — 225 400 600 800 1200 a b c d e Base $ Price (2- or 3-pole) Mains Rating (Amperes) — — 100 200 — 400 600 800b — 1098. 1344. 2066. 2550. 3550. 240 Vac Maximum Mounting Space (In.) 51 51 — 45 45 45 — Base $ Price 2-pole 2544. 2544. — 4840. 7298.c 11098. — Solid Neutral (Main Lugs and Main Switch) 600 Vac Base $ Price 3-pole 3104. 3104. — 6158. 8758.c 13704.c — 2-pole 3026. 3026. — 5906. 7968.de 11128.d — Ampere Rating 3-pole 3632. 3632. — 7300. 9338.d 13724.d — $ Price 100 A 200 A 225 A 400 A 600 A 800 A 1200 A 294. 294. 294. 384. 556. 786. 912. Pricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches. 800 A switch unit with provision for UL Class L fuses. Switches for use with 300 V Class T fuses are also available at no additional cost. For 600 Vac UL Class T fuse provision on main switch, add $ 321.00 250 Vdc rating. Table 9.165: Branch Switch $ Price f Unit Ampere Rating Switch Type Twin Mounted Branch Switches g 30 A-Blank QMB 60 A-Blank QMB QMB 100 A-Blank QMJ hm 200 A-Blank QMJ hm 60 A-30 A QMB 100 A-30 A QMB 100 A-60 A QMB QMB 30 A-30 A QMJ hm QMB 60 A-60 A QMJ hm QMB 100 A-100 A QMJ hm 200 A-200 A Single Mounted Branch Switches 200 A QMB 400 A QMB 400 Ai QMB 400 A QMJ hm 600 A QMB 600 A QMJ hm 800 Al QMB f g h i j k l m 240 Vac 2-pole $ Price 3-pole $ Price 592. 600 Vac Space Only $ Price 784. 898. 1104. — — — — — — Unit Mounting Height (In.) 2-pole $ Price 3-pole $ Price Space Only $ Price 2576. 1446. 294. 396. 462. 396. 462. 396. 4.5 6 7.5 6 7.5 6 2274. 462. 7.5 1446. 294. 4.5 1446. 396. 6 462. 396. 462. 7.5 6 7.5 580. 878. 9 15 580. 9 878. 15 294. 4.5 852. 392. 6 — — — 1276. 1592. 1984. 1216. 1822. — — — 1012. 1822. 2274. 396. 6 826. 1120. 294. 4.5 — 4.5 — 6 — — 1216.h 1216. 1216.h 1216. 1822.j 1822. 3970. 5154. 9 15 9 — 15 — 15 1984.h 4300.h 4098.hi 4098. 5264.hk 5264. 10682.k 2576. 5764.h 5552.hi 5552. 6962.hk 6962. 10682.k — — 826. — 1120. — — 1282. 294. — 1576. — — — — 1484. 3204. 3040.i — 4888.j — 10682. 2034. 4562. 4360.i — 6374.hj — 10682.j 396. — — 580. 878. 580. — 878. — 878. Unit Mounting Height (In.) 2274. Pricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches. $ Price is per twin switch. 250 Vdc rating. For use with Class T fuses only. Use 300 V Class T fuses on 240 Vac max. systems and 600 V Class T fuses on 600 Vac max. systems. Switches for use with 300 V Class T fuses are also available at no additional cost. For 600 Vac UL Class T fuse provision on branch switch, add $ 307.00 800 A switch unit with provision for UL Class L fuses. QMJ switches are available in NEMA 1 enclosures only. Table 9.166: Accessories Electrical Interlocks Number of Contacts Normally Open 1 2 n o Branch Switches 30–200 A $ Price Normally Closed 1 2 472. Mains Ampere Rating Sub-feed Lugs n for Main Lugs Interior n Feed-through Lugs for Main Switch Interior 200 A 225 A 400 A 600 A 800 A 1200 A — — — 282. 466. 856. 1150. 1440. Copper Bus Bars 488. 488. 720. 1148. 1372. 1428. 872.o 1268.o 1512.o — No extra box height required. Box height increases 6 in. Not available in Type 3R/5/12 construction. Table 9.167: Circuit Breakers, Twin Mounted H-frame— $ Price Per Twin Unit Circuit Breaker Ampere Rating $ Price—3-pole Left Unit Right Unit Unit Mounting Height (In.) 15–150 A 15–150 A 6 240 V HD 2914. 480 V HG 3572. HD 3324. 600 V HG 3814. HD 3674. HG 4018. Space Only 396. Note: See the Supplemental and Obsolescence Digest for merchandised motor starter units, QMB RTI panelboards, and replacement switches for Series 1-4 and D2 QMB panelboards. Table 9.168: Circuit Breaker, Single Mounted JD-LA— $ Price Each $ Price—3-pole Circuit Breaker Ampere Rating Unit Mounting Height (In.) 150–250 A 225–400 A 6 7.5 600 V JD JG 3800. — 5814. — Space Only LA — 396. 462. 5664. Table 9.169: UL Listed Short Circuit Ratings Starter Size 0 1 2 3 9-36 Fusible Switch—600 V Max. (w/Class R or J Fuses) RMS Sym. Amps 100,000 100,000 100,000 100,000 PE1 Discount Schedule Thermal-magnetic Circuit Breaker 600 V Max. RMS Sym. Amps 5,000 5,000 5,000 5,000 © 2012 Schneider Electric All Rights Reserved QMB Factory Assembled Panelboards Common Features Class 4620 / Refer to Catalog 4620CT9601 www.schneider-electric.us Table 9.175: Aluminum Compression Lugs VCEL— Main or Branch Switches Item $ Price Equipment Ground Bar 180. Copper Ground Bar 148. a Insulated/Isolated Ground Bar ab Name Plates 78. c a Add to Equipment Ground Bar $ Price. b $ Price an additional Neutral Assembly from Table 9.164 on Digest page 9-36 for Al insulated ground bar or from Table 9.171 for Cu insulated ground bar. c Standard white face/black letter laminated bakelite, 1 in. x 3.5 in. adhesive backed or screw mountable with screws in a bag assembly. ($ Price includes engraving.) Aluminum Compression Lugs VCEL 100 A #8–1/0 Al or Cu 200 A #4–300 kcmil Al or Cu 400 A 2/0–500 kcmil Al or Cu 600 A 2/0–500 kcmil Al or Cu 800 A 2/0–500 kcmil Al or Cu or 500 kcmil Cu or 500–750kcmil Al. Copper Compression Lugs 200 A 400 A 600 A 800 A Table 9.172: Copper Mechanical Lugs—Main Switch Interiors Copper Mechanical Lugs 200 A 400 A 600 A 800 A $ Price 108. 148. 168. 196. Table 9.173: Copper Compression Lugs—Main Lug Interiors $ Price 108. 148. 168. 316. 836. Voltage Surge Current 120/240 V 208Y/120 V 240/120 Vac 480Y/277 Vac 600Y/347 Vac Rating 3Ø4W kA 1Ø3W 3Ø4W 3Ø4W 3Ø4W High Leg 100 — 14310. — 15410. — 120 — 15654. — 16754. — 160 — 18586. — 19686. — 200 19196. 23596. 23596. 26896. 26896. 240 23760. 27440. 27440. 31460. 31460. d Requires 9 in. of mounting height. Table 9.178: SPD Options Surge Counter Dry Contacts Remote Monitor $ Price Standard Standard 2588. QMB Layout Information Table 9.174: Aluminum Compression Lugs VCEL— Main Lug Interiors Aluminum Compression Lugs VCEL 225 A 400 A 600 A 800 A 1200 A $ Price 108. 148. 168. 196. Table 9.177: Surgelogic™ SPD for QMB d Surgelogic SPD Options Copper Compression Lugs 225 A 400 A 600 A 800 A 1200 A 262. 9 $ Price 868. 894. 1108. 1352. N/A 3054. Standard 58. 98. 128. 246. Table 9.176: Copper Compression Lugs—Main Switch Interiors Table 9.171: Copper Neutral Copper Neutral 125–400 A 600 A 800 A 1200 A Hinged Trim Weatherproof or Dusttight Cabinets—Type 3R, 5, 12; 800 A Max. Mechanical Lugs 225 A–1200 A $ Price $ Price 58. 90. 118. 200. 236. Main Switch or Main Lugs 100 A twin QMB 6" H @ 240 Volt Maximum Mounting Space for Branch Units 60 A twin QMB 6" H @ 600 Volt 30/30 @ 240 or 600 V or 60/60 @ 240 V are 4.5" high Wiring Gutter 100 A twin QMB 7.5" H @ 600 Volt 100 A twin QMJ 6" H @ 600 Volt 200 A QMB 9" mounting height, 200 Amp twin QMJ 7.5" mounting height 400 A QMJ 9" H, 400 A Class T 9" H, 400, 600 or 800 A QMB all require 15" H 38" To maximize the quantity of branch switches, use QMJ switches from Digest page 9-36. Class J fuses are available in time delay construction suitable for motor and transformer loads. © 2012 Schneider Electric All Rights Reserved PE1 Discount Schedule PANELBOARDS Table 9.170: Ground Bar and Name Plates 9-37 Modifications for Factory Assembled Panelboards Class 1640, 1670, 2110, 4620, 6650 / Refer to Catalog 2110CT9701, 1640CT0801, 4620CT9601 www.schneider-electric.us 9 Table 9.179: NQ and NF Lighting Contactors—Mechanically Held Table 9.181: NQ and NF Panelboard Split Bus Bars (Furnish a one-line power and control voltage connection diagram.) Maximum Ampacity MLO Mechanically Held Ampacity Type Minimum Additional Box Height Required a H (In.) $ Price PANELBOARDS Square D™ Brand PB b 30 A 2P PBM10B 3772. 18 60 A 2P PBP10B 4634. 18 75 A 2P PBN10B 4986. 18 100 A 2P PBQ10B 5072. 18 150 A 2P PBR10B 7156. 18 200 A 2P PBV10B 8692. 18 225 A 2P PBW10B 9830. 18 30 A 3P PBM11B 3740. 18 60 A 3P PBP11B 4754. 18 75 A 3P PBN11B 5628. 18 100 A 3P PBQ11B 6454. 18 150 A 3P PBR11B 8078. 18 200 A 3P PBV11B 8736. 18 225 A 3P PBW11B 10062. 18 30 A 2P 9202030 4694. 18 60 A 2P 9202060 5954. 18 75 A 2P 9202075 5954. 18 100 A 2P 9202100 6194. 18 150 A 2P 9202150 9242. 18 200 A 2P 9202200 10882. 18 225 A 2P 9202225 11875. 18 30 A 3P 9203030 5436. 18 60 A 3P 9203060 7638. 18 9203075 7638. 18 9203100 9184. 18 150 A 3P 9203150 12998. 18 200 A 3P 9203200 14434. 18 225 A 3P 9203225 15750. 18 a b c Ampacity MLO Tin or Silver Plating 100 A 1240. 510. e 1240. 610. e 400 A 2080. 830. 600 A 2080. 800 A 1200 A 125 A 225 A 250 A d e f g h 44 56 62 2-pole 3-pole 560. 662. 786. 1094. 1320. 662. 858. 858. 1238. 1442. Split Bus 7.5 in. 9 in. 12 in. 12 in. 18 in. Main Circuit Breaker Without Overload Trip (Automatic Molded Case Switch) • (Not UL Listed) $ Price as standard main circuit breaker, no $ Price Adder. Shunt Trip Circuit Breakers • See Digest page 7-35 for pricing. Note: For molded case switch and automatic molded case switch short circuit current ratings, See Digest page 7-33. Special Features For information on the following special features, please see the Supplemental and Obsolescence Digest. • Powerlogic™ metering k • Customer equipment space (NQ and NF) k • Increased box depth k • Increased gutters–top, bottom, and sides k • Non-standard paint k • Welded base channel k • Type 1 gasketed k • Type 2 drip hood k • Type 3R/4/4X/5/12 stainless steel enclosure k • Type 4X fiberglass enclosure k • Stainless steel trim front k • Padlockable hasp k • Special locks (Corbin, Yale, Best) k • Equal height boxes k • Common trim to cover two equal height boxes k • Panelboard skirt—hides conduits feeding a panelboard k • Panelboard wireway—for terminating conduit in wireway endwall k • Keyed mechanical interlocking of two or more circuit breakers (I-Line and QMB) k • Motor operators (I-Line only) • Panelboard interiors and special fronts to fit existing boxes • A standard panelboard box has one blank endwall and one with knockouts. Blank endwalls or knockouts in both endwalls are also available k 750 A/in2 Al 340. f 456. f 572. f 1050. f 1080. fg 2080. 1490. 1244. g 2080. 1710. 1432. gh Standard copper bus plating material – NQ and NF: Silver plated bus/tin plated connectors – I-Line and QMB: Tin. NQ available in 42 circuit only. Not available in NQ. HCN 600 A and all 800–1200 A I-Line interiors available with copper bus only. 1200 A QMB with current density-rated bussing not available. k 9-38 Box Height (ft.) Note: For applications with main circuit breaker panelboards, contact your local Schneider Electric representative or distributor. j For I-Line panelboards, dimension includes height of “SL” sub-feed lug kit from Digest, plus 3 in. from available branch mounting space. Current Density Rated Bus $ List Price Adder 1000 A/in2 Cu Split Additional Mounting Height Required On Split Bus Section j $ Price 225 A 400 A 600 A 800 A 1200 A Table 9.180: Current Density Rated Panelboard Bus and Special Plating for Copper Bus Copper Bus Special Plating $ List Price Adder d Main Table 9.182: I-Line™ Panelboard Split Bus Bars NF panels require 18 in. of additional box height regardless of contactor ampacity or manufacturer. If two-wire control is required—Square D™ brand. Add 708. (No additional width or depth required) If two-wire control is required—ASCO type. Add 1412. (No additional width or depth required) Ampacity 3-phase When greater than 125 A lugs are required on the split section of the bus, contact your local Schneider Electric representative or distributor for the box height. ASCO Type 920 c 75 A 3P 1-phase NQ Panelboards—125 A Maximum Lugs on Split Bus Section i 18 30 225 A 600. 900. 18 30 30 NF Panelboards—125 A Maximum Lugs on Split Bus Section i 18 30 250 A — 900. 18 30 30 i 100 A 3P Maximum Number of Pole Spaces Available $ List Price Adder PE1 Discount Schedule Supported by the Panelboard Product Selector. © 2012 Schneider Electric All Rights Reserved Panelboards NQ and NF Terminal Data Class 1640, 1670, / Refer to Catalog 1670CT0701, 1640CT0801 www.schneider-electric.us Table 9.183: NQ Standard Aluminum Mechanical Lugs—Main Lugs NQ Ampere Rating Lug Wire Range 100 A one #6-2/0 Al or Cu 225 A one #6-350 kcmil Al or Cu 400 A one 1/0-750 kcmil or two 1/0-350 kcmil Al or Cu 600 A two 1/0-750 kcmil Al or Cu PANELBOARDS Panel Type Panel Type Ampere Rating 100 A QOB Lug Wire Range a one #4–#2/0 Al or Cu FI one #14–#1/0 Al or Cu 150 A HD, HG, HJ, HL one #14–#3/0 Al or Cu 225 A QB, QD, QG, QJ one #4-300 kcmil Al or Cu JD, JG, JJ, JL NQ 250 A a Circuit Breaker Type 9 Table 9.184: NQ Standard Aluminum Mechanical Lugs—Main Circuit Breaker one #3/0–350 kcmil Al or Cu a DJ one #2–600 Cu or #2–500 Al KI one #1/0–350 kcmil Al or Cu 400 A LA, LH one #1–600 kcmil Al or Cu or two #1–250 kcmil Al or Cu 600 A LC two #4/0-500 kcmil Al or Cu The lug range shown is for the highest amperage of the circuit breaker frame shown in the table. Table 9.185: NF Standard Mechanical Lugs—Main Lugs Panel Type Ampere Rating 125 A NF Lug Wire Range one #6–2/0 Al or Cu 250 A one #6–350 kcmil Al or Cu 400 A one #1/0–750 kcmil or two #1/0–350 kcmil Al or Cu 600 A two #1/0–600 kcmil Al or Cu 800 A three #4/0–500 kcmil Al or Cu Table 9.186: NF Standard Mechanical Lugs—Main Circuit Breaker Panel Type NF b © 2012 Schneider Electric All Rights Reserved Ampere Rating Circuit Breaker Type 125 A ED, EG, EJ 100 A FI 150 A HD, HG, HJ, HL JD, JG, JJ, JL 250 A Lug Wire Range b one #14–#2/0 Al or Cu one #14–#1/0 Cu or one #12–#1/0 Al one #14–#3/0 Al or Cu one #3/0–350 kcmil Al or Cu b DJ one #2–600 Cu or #2–500 Al KI one #1/0–350 kcmil Al or Cu 400 A LA, LH 600 A LC, LI, LE, LX, LXI one #1–600 kcmil or two #1–250 kcmil Al or Cu two #4/0–500 kcmil Al or Cu The lug range shown is for the highest amperage of the circuit breaker frame shown in the table. 9-39 I-Line™ and QMB Terminal Data Class 2110, 4620 / Refer to Catalog 2110CT9701, 4620CT9601 www.schneider-electric.us 9 Table 9.187: Standard Mechanical Lugs—Main Lugs Panel Type Ampere Rating 100 A 225 A 400 A 600 A 800 A 1200 A I-Line Lug Wire Range a PANELBOARDS — one #6–300 kcmil Al or Cu two #2–600 kcmil Al or Cu two #2–600 kcmil Al or Cu (4) 3/0–750 kcmil Al or Cu (4) 3/0–750 kcmil Al or Cu Wire Range Wire Bending Space per NEC Table 373-6 a — one #6–300 kcmil Al or Cu one #2–600 kcmil Al or Cu two #2–500 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu (4) 3/0–500 kcmil Al or Cu Table 9.188: Standard Mechanical Lugs—Main Circuit Breaker Panel Type I-Line Ampere Rating 100 A 150 A 225 A 250 A 400 A 600 A 800 A 1200 A Circuit Breaker Type FA, FH, FI HD, HG, HJ, HL KI JD, JG, JJ, JL LX, LXI, LE LA, LH LC, LI, LX, LXI, LE MG, MJ, PG, PJ, PL PG, PJ, PL, RGC, RJC, RLC Lug Wire Range a one #14-1/0 Al or Cu one #14-3/0 Al or Cu one #4-300 kcmil Al or Cu one #1/0-#4/0 Al or Cu two #1-350 kcmil Al or Cu one #1-600 or two #1-250 kcmil Al or Cu two 4/0-500kcmil Al or Cu three 3/0-500 kcmil Al or Cu four 3/0-500 kcmil Al or Cu Wire Range Wire Bending Space per NEC Table 373-6 a one #14-1/0 Al or Cu one #14-3/0 Al or Cu one #4-300 kcmil Al or Cu one #1/0-300 kcmil Al or Cu two #1-350 kcmil Al or Cu one #1-600 kcmil Al or Cu two 4/0-500kcmil Al or Cu three 3/0-500 kcmil Al or Cu four 3/0-500 kcmil Al or Cu Table 9.189: Standard Mechanical Lugs—Main Lugs Panel Type Mains Ampere Rating 225 A 400 A 600 A QMB 800 A 1200 A 1600 A Lug Wire Range a Wire Range Wire Bending Space per NEC Table 373-6 a one #6–300 kcmil Al or Cu one #6–300 kcmil Al or Cu and, one 3/0–750 kcmil Al or Cu two 3/0–500 kcmil Al or Cu one #6–300 kcmil Al or Cu one #6–300 kcmil Al or Cu and, one 3/0–750 kcmil Al or Cu two 3/0–500 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu or (4) 3/0–750 kcmil Al or Cu two 3/0–750 kcmil Al or Cu (4) 3/0–500 kcmil Al or Cu or (4) 3/0–750 kcmil Al or Cu (4) 3/0–750 kcmil Al or Cu VCEL compression lugs Standard. Table 9.190: Standard Mechanical Lugs—Main Switch Panel Type QMB Mains Ampere Rating 200 A 400 A 600 A 800 A Lug Wire Range a Wire Range Wire Bending Space per NEC Table 373-6 a #4–300 kcmil Al or Cu 3/0–600 kcmil Al or Cu 3/0–600 kcmil Al or Cu 3/0–600 kcmil Al or Cu one #4–300 kcmil Al or Cu two 3/0–600 kcmil Al or Cu two 3/0–600 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu Table 9.191: Standard Mechanical Lugs—QMB Branch Switch Units Panel Type QMB Switch Ampere Rating 30 A 60 A 100 A 200 A 400 A 600 A 800 A Lug Wire Range a Wire Range Wire Bending Space per NEC Table 373-6 a one #14–#2 Al or Cu one #14–#2 Al or Cu one #14–1/0 Al or Cu one #4–300 kcmil Al or Cu two 3/0–600 kcmil Al or Cu two 3/0–600 kcmil Al or Cu (3) 3/0–600 kcmil Al or Cu one #14–#2 Al or Cu one #14–#2 Al or Cu one #14–1/0 Al or Cu one #4–300 kcmil Al or Cu two 3/0–500 kcmil Al or Cu two 3/0–500 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu Table 9.192: Standard Mechanical Lugs—QMJ Branch Switch Units b Panel Type QMJ a b 9-40 Switch Ampere Rating 30 A 60 A 100 A 200 A 400 A 400 A 600 A Lug Wire Range a Wire Range Wire Bending Space per NEC Table 373-6 a one #14–#2 Al or Cu one #14–#2 Al or Cu one #14–1/0 Al or Cu one #6–300 kcmil Al or Cu one 1/0–750 kcmil Al or Cu two 1/0–300 kcmil Al or Cu two 3/0–600 kcmil Al or Cu one #14–#2 Al or Cu one #14–#2 Al or Cu one #14–1/0 Al or Cu one #6–300 kcmil Al or Cu one 1/0–750 kcmil Al or Cu two 1/0–300 kcmil Al or Cu two 3/0–600 kcmil Al or Cu (#) = Number of conductors per phase. Use only 90 oC insulated conductors based on an ampacity of 75 oC conductors. © 2012 Schneider Electric All Rights Reserved I-Line™ Combo Panelboard Combination Panelboards www.schneider-electric.us Part Number Panelboard Ampacity List $ Price Single/ Duplex Lighting Section Type Lighting Lighting Section Section Amperage Circuits Busing Ground Bar Box 4 Piece Trim Without Door Trim with Door NEMA 3R/5/12 (Includes Fromnt) 18 18 18 18 18 18 18 18 18 18 18 18 CP18864N3Q2C CP18864N3Q2 CP18864N4Q2C CP18864N4Q2 CP18864N3F2C CP18864N3F2 CP18864N4F2C CP18864N4F2 CP18866N3Q4C CP18866N4Q4C CP18866N3F4C CP18866N4F4C 400 400 400 400 400 400 400 400 600 600 600 600 10334.00 7650.00 10729.00 8045.00 17549.00 14749.00 18147.00 15388.00 15032.00 15428.00 21270.00 21863.00 S S S S S S S S S S S S NQ NQ NQ NQ NF NF NF NF NQ NQ NF NF 225 225 225 225 250 250 250 250 400 400 400 400 30 30 42 42 30 30 42 42 30 42 30 42 Cu Al Cu Al Cu Al Cu Al Cu Cu Cu Cu PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686DB HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )4P HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686T( )HR HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP HC2686WP 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 CP23734N3Q2C CP23734N3Q2 CP23734N3F2C CP23734N3F2 CP23736N3Q4C CP23736N3F4C CP23914N4Q2C CP23914N4Q2 CP23914N5Q2C CP23914N5Q2 CP23914N4F2C CP23914N4F2 CP23914N5F2C CP23914N5F2 CP23916N4Q4C CP23916N5Q4C CP23916N4F4C CP23916N5F4C CP23916N44Q4C CP23916N53Q4C 400 400 400 400 600 600 400 400 400 400 400 400 400 400 600 600 600 600 600 600 10686.00 7942.00 18065.00 15249.00 16159.00 22539.00 11091.00 8346.00 11604.00 8797.00 18672.00 15855.00 19341.00 16508.00 16563.00 17076.00 23145.00 23814.00 26032.00 26141.00 S S S S S S S S S S S S S S S S S S D D NQ NQ NF NF NQ NF NQ NQ NQ NQ NF NF NF NF NQ NQ NF NF NQ NQ 225 225 250 250 400 400 225 225 225 225 250 250 250 250 400 400 400 400 400 400 30 30 30 30 42 42 42 42 54 54 42 42 54 54 42 54 42 54 42/42 54/30 Cu AL Cu AL Cu Cu Cu Al Cu Al Cu Al Cu Al Cu Cu Cu Cu Cu Cu PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTA PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU HC3273DB9 HC3273DB9 HC3273DB9 HC3273DB9 HC3273DB9 HC3273DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HC3291DB9 HCM73T( )V HCM73T( )V HCM73T( )V HCM73T( )V HCM73T( )V HCM73T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM91T( )V HCM73T( )VD HCM73T( )VD HCM73T( )VD HCM73T( )VD HCM73T( )VD HCM73T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD HCM91T( )VD N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 CP32866N44Q4C CP32866N53Q4C CP32866N4BQ4C CP32866N44F4C CP32866N53F4C CP32866N4BF4C CP32868N44Q6C CP32868N53Q6C CP32868N3BQ6C CP32868N4BQ6C CP32868N5BQ6C CP32868N44F6C CP32868N53F6C CP32868N3BF6C CP32868N4BF6C CP32868N5BF6C 600 600 600 600 600 600 800 800 800 800 800 800 800 800 800 800 26066.00 26170.00 18362.00 38703.00 38763.00 24681.00 36447.00 36552.00 23026.00 23415.00 23300.00 38744.00 38805.00 23981.00 24563.00 24599.00 D D D D D D D D D D D D D D D D NQ NQ NQ NF NF NF NQ NQ NQ NQ NQ NF NF NF NF NF 400 400 400 400 400 400 600 600 600 600 600 600 600 600 600 600 42/42 54/30 42/O 42/42 54/30 42/O 42/42 54/30 30/O 42/O 54/O 42/42 54/30 30/O 42/O 54/O Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU PK32DGTACU HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HC4486DB HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( ) HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HCR86T( )D HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP HC4486WP 9 I-Line Mounting Space Table 9.194: RTI Cabled Lighting Section Kit for I-Line Combo Panelboard Part Number Description MLO Panelboard Ampacity List $ Price Lighting Section Type Lighting Section Circuits NFICRT418L1C NF Lighting Section Kit 125 1528.00 NF 18 NFICRT442L2C NF Lighting Section Kit 250 1763.00 NF 42 NFICRT442L4C NF Lighting Section Kit 400 2353.00 NF 42 NFICRT442L6C NF Lighting Section Kit 600 2008.00 NF 42 NQICRT418L1C NQ Lighting Section Kit 100 1564.00 NQ 18 NQICRT442L2C NQ Lighting Section Kit 225 1373.00 NQ 42 NQICRT442L4C NQ Lighting Section Kit 400 2156.00 NQ 42 NQICRT442L6C NQ Lighting Section Kit 600 2332.00 NQ 42 NQICRT418C1C Contactor with 18 Circuit NQ Lighting Section Kit 100 1225.00 NQ 18 NFICRT418C1C Contactor with 18 Circuit NF Lighting Section Kit 125 1440.00 NF 18 © 2012 Schneider Electric All Rights Reserved PANELBOARDS Table 9.193: Interior Boxes and Fronts — Includes Solid Neutral 9-41 Series Ratings NQ Panelboards Class 1640 www.schneider-electric.us 9 This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located in the same enclosure or a remote main located in a separate enclosure. Table 9.195: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical) PANELBOARDS Square D™ Brand Maximum Maximum Short Integral or Remote System Circuit Main Circuit Breakers Voltage Current and Remote Main AC ab Rating Fuses 22,000 25,000 Type 1 Pole 2 Pole 3 Pole QO (B) 15–30 A — — LD, HD, JD QO (B) QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–125 A 15–60 A 15–60 A 15–60 A — — — — — — — — — QO (B) QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–125 A 15–60 A 15–60 A 15–60 A — — — — — — — — — LG QO (B) QO (B) VH QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–125 A 15–60 A 15–60 A — — — — — — — — LJ QO (B) GFI QO (B) EPD 15–30 A 15–30 A 40–60 A 40–60 A — — HJ, JJ QO (B) QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–125 A 15–60 A 15–60 A 15–60 A — — — — — — — — — QO (B) QO(B) VH QO (B) H QO (B) GFI QO (B) EPD QO(B) AFI QO(B) CAFI 15–70 A 15–70 A — — — 15–20 A 15–20 A 15–125 A 15–125 A 15–100 A 15–30 A 15–60 A — — — — — — — — — DJ 400 A QO (B) QO (B) VH QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A — 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 150 A 15–60 A 15–60 A — — — — — — — — QJ QO (B) QO (B) AS QO (B) VH QO (B) PL QO (B) GFI QO (B) AFI QO (B) CAFI 15–70 A 15–30 A — 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–30 A 150 A 15–60 A 15–60 A — — — — — — — — — HL, JL QO (B) QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–125 A 15–60 A 15–60 A 15–60 A — — — — — — — — — LA/LH (L) 34200MC LA/LH (L) 34225MC LA/LH (L) 34250MC LA/LH (L) 34400MC QO (B) 15–30 A 15–30 A 15–30 A LD QO (B) QO (B) VH QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI 15–70 A 15–30 A 15–30 A 15–30 A — 15–20 A 15–20 A 15–125 A — 15–125 A 15–150 A 15–60 A 15–30 A 15–60 A 15–30 A — 15–30 A — — — — DJ–W 150 A MC QO (B) QO (B) VH QO (B) GFI QO (B) AFI 15–70 A — 15–30 A 15–20 A 15–100 A — 15–125 A 15–150 A 15–60 A — — — DJ–W 250 A MC QO (B) QO (B) VH QO (B) GFI QO (B) AFI 15–70 A — 15–30 A 15–20 A 15–100 A — — 15–150 A 15–60 A — — — QO (B) QO (B) VH QO (B) GFI QO (B) AFI 15–70 A — 15–30 A 15–20 A 15–100 A — — 15–150 A 15–60 A — — — 65,000 120/240 1P/3W LJ 100,000 125,000 18,000 25,000 208Y/120 3P/4W 240/120 V 3P/4W 30,000 DJ–W 600 A MC Square D™ Brand Maximum Maximum Short Integral or Remote System Circuit Main Circuit Breakers Voltage Current and Remote Main AC ab Rating Fuses 100,000 240/120 V 3P/4W 240/120 V 3P/4W a b c d e f g h 9-42 Type 1 Pole LG 15–70 A 15–70 A — 15–30 A 15–30 A — 15–20 A 15–20 A 15–125 A — 15–125 A 15–150 A 15–100 A — 15–60 A 15–30 A 15–60 A 15–30 A — 15–30 A — — — — LJ QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI 15–70 A 15–70 A — 15–30 A 15–30 A — 15–20 A 15–20 A 15–125 A — 15–125 A 15–150 A 15–100 A — 15–60 A 15–30 A 15–60 A 15–30 A — 15–30 A — — — — LL QO (B) GFI QO (B) EPD QO (B) EPE — — — DJ 400 A QO (B) QO (B) VH QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A — 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A — — 15–150 A 15–60 A — 15–60 A — — — — — QJ QO (B) QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI 15–70 A — 15–30 A 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–30 A — 15–150 A 15–60 A 15–30 A 15–60 A 15–50 A 15–60 A 15–50 A 15–60 A 15–50 A — — — — LJ QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A — — — 15–20 A 15–20 A 15–125 A — 15–125 A 15–150 A 15–100 A — 15–30 A — 15–60 A — — — — — QO (B) VH QO (B) QO (B) GFI QO (B) EPD QO (B) EPE QO (B) PL QO (B) AFI QO (B) CAFI 15–70 A 15–30 A 15–30 A — 15–30 A 15–20 A 15–20 A 15–125 A 15–100 A 15–60 A 15–50 A 15–60 A 15–50 A — 15–50 A 15–60 A — — — — — QD QO (B) QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI 15–70 A — 15–30 A 15–30 A 15–30 A — 15–20 A 15–20 A 15–125 A 15–30 A — 35–150 A 15–60 A 15–30 A 15–60 A 15–50 A 15–60 A 15–50 A — 15–50 A — — — — ED, FD QO (B) QO (B) GFI QO (B) AFI QO (B) CAFI 15–70 A 15–30 A 15–20 A 15–20 A 15–125 A 15–100 A 15–60 A 15–50 A — — — — KD QO (B) QO (B) AS QO (B) GFI QO (B) AFI 15–70 A 15–30 A 15–30 A 15–20 A 15–125 A 15–100 A 15–30 A 15–30 A 15–60 A — — — HD, JD QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI 15–70 A — — 15–30 A 15–30 A — 15–20 A 15–20 A 15–125 A 15–100 A — 35–150 A 15–100 A — 15–60 A 15–50 A 15–60 A 15–50 A — 15–50 A — — — — LD QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI 15–70 A 15–30 A — 15–30 A 15–30 A — 15–20 A 15–20 A 15–125 A — 15–125 A 15–150 A 15–100 A — 15–60 A 15–30 A 15–60 A 15–30 A — 15–30 A — — — — 65,000 208Y/120 3P/4W 240/120 V 3P/4W 22,000 Square D™ Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges cdef QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI Square D™ Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges cdef MG HG, JG Table 9.195: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical) 25,000 2 Pole — — — 3 Pole 15–30 A 15–30 A 15–30 A For shown circuit breakers rated less than this maximum voltage, the indicated short circuit current rating also applies, but at the voltage rating of the circuit breaker Short circuit tests are conducted at 100–105% of the maximum rated voltage of the panelboard. Suffixes HID, and SWD may also be applied to the applicable branch circuit breakers shown above. Suffix SWN may not be applied in combination with LC main breakers. Where QO (B) circuit breakers are shown above, QO (B) H, QO (B) VH, and QOH (B) circuit breakers may also be used. Where QO (B) GFI circuit breakers are shown above, QO (B) EPD and/or QO (B) EPE circuit breakers may also be used. QO–EPE only comes in 3 pole construction. Where QO (B) AFI circuit breakers are shown above, QO (B) CAFI circuit breakers may also be used. To achieve selective coordination, the rating of the DJ main circuit breaker must be at least two times greater than the ampere rating of any branch circuit breaker. For complete series ratings for Delta Systems please reference NQ/NQM Panelboards Information Manual 80043–712–06. © 2012 Schneider Electric All Rights Reserved Series Ratings NQ Panelboards Class 1640 www.schneider-electric.us Table 9.196: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical) Square D™ Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges cdef Type 1 Pole LA, MA Q2L–H QDL — — 100–225 A 100–225 A 70–225 A 70–225 A LC400A QO (B) QO (B) VH QO (B) GFI QO (B) AFI QO (B) CAFI 15–70 A 15–70 A 15–30 A 15–20 A 15–20 A 15–70 A — 15–125A 15–100 A 15–60 A 15–30 A — — — — LC600A QO (B) VH QO (B) GFI QO (B) AFI QO (B) CAFI 15–70 A 15–30 A 15–20 A 15–20 A 15–125 A 15–100 A 15–60 A 15–30 A — — — — MG QO (B) VH 15–30 A 15–30 A LC400A QO (B) QO (B) VH QO (B) GFI QO (B) AFI QO (B) CAFI 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A 15–30 A — 15–125 A 15–100 A 15–60 A — — — — — QO (B) VH QO (B) GFI QO (B) AFI QO (B) CAFI 15–30 A — 15–20 A 15–20 A 15–125 A 15–150 A — 15–30 A — — — — QO (B) QO (B) VH QO (B) H QO (B) QO (B) VH QO (B) GFI QO (B) AFI QO (B) CAFI 15–70 A 15–125 A — — — 15–150 A — 15–100 A — 15–70 A 15–150 A — — 110–125 A 15–150 A 15–30 A 15–60 A — 15–20 A — — 15–20 A — — 42,000 LC600A DJ400A DJ_W 2 Pole 3 Pole QO (B) EPD — EG, FG, KG QO (B) QO (B) GFI QO (B) AFI QO (B) CAFI 15–70 A 15–30 A 15–20 A 15–20 A 15–125 A 15–100 A 15–60 A — — — — — QG QO (B) QO (B) VH QO (B) GFI QO (B) PL QO (B) AFI QO (B) CAFI 15–70 A — 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–30 A — 35–150 A 15–60 A 15–50 A 15–60 A 15–30 A — — — — HG, JG QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) EPE QO (B) PL QO (B) AFI QO (B) CAFI 15–70 A — — 15–30 A 15–30 A — 15–30 A 15–20 A 15–20 A 15–125 A 15–100 A — 35–150 A 15–100 A — 15–60 A 15–50 A 15–60 A 15–50 A — 15–50 A 15–60 A 15–30 A — — — — FC_ or KC_22___ FC_ or KC_34___ QO (B) QO (B) AS 15–70 A 15–30 A 15–100 A 15–100 A 15–30 A 15–30 A LG QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A — 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A — 15–125 A 15–150 A 15–100 A — 15–60 A 15–30 A 15–60 A 15–30 A — — — — LJ QO (B) QO (B) GFI QO (B) EPD QO (B) EPE 15–70 A 15–30 A 15–30 A — 15–125 A 40–60 A 40–60 A — — — 15–30 A 15–30 A LL QO (B) EPD QO (B) EPE — — — — 15–30 A 15–30 A FC_ or KC_22___ FC_ or KC_34___ QO (B) GFI QO (B) AFI 15–30 A 15–20 A 15–30 A — — — DJ400A QO (B) QO (B) H QO (B) VH QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A — — 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A — 15–100 A — — 15–150 A 15–60 A — 15–60 A — — — — — 240/120 V 3P/4W EJ QO (B) 15–70 A 15–125 A 15–100 A LJ QO (B) QO (B) VH QO (B) H QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–70 A — — — 15–20 A 15–20 A 15–125 A — 15–125 A 15–150 A 15–100 A — 15–30 A — 15–60 A — — — — — HJ, JJ QO (B) QO (B) H QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A — — 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–100 A 15–100 A — — 35–150 A 15–60 A 15–30 A 15–60 A 15–50 A 15–60 A 15–50 A — — — — 100,000 © 2012 Schneider Electric All Rights Reserved 15–30 A e f 3 Pole QO (B) QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–70 A 15–30 A 15–30 A 15–20 A 15–20 A 15–125 A 15–100 A 15–60 A — 15–60 A — — — — — 200 A Max. Class T6, J Fuses QO (B) QO (B) GFI QO (B) EPD 15–70 A — — 15–125 A — — 400 A Max. Class T3 Fuses QO (B) QO (B) GFI QO (B) EPE QO (B) EPD 15–70 A 15–30 A — 15–30 A 15–125 A 15–100 A 15–60 A 15–50 A — 15–50 A 15–60 A 15–50 A 42,000 400 A Max. Class T3 Fuses QO (B) VH 15–30 A 15–125 A — 50,000 400 A Max. Class T3 Fuses QO (B) VH — — 15–30 A 400 A Max. Class J Fuses QO (B) VH QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI 15–70 A — — 15–20 A 15–20 A 15–125 A — — — — — 15–50 A 15–50 A — — 400 A Max. Class T6 Fuses QO (B) VH QO (B) AFI 15–70 A 15–20 A 15–125 A 15–150 A — — 200 A Max. Class T3 Fuses QO (B) QO (B) VH QO (B) GFI QO (B) EPD QO (B) EPE QO (B) AFI QO (B) CAFI QOT 15–70 A — 15–30 A 15–30 A — 15–20 A 15–20 A 15–30 A 15–125 A 15–100 A — 15–30 A 15–60 A — 15–60 A 15–50 A — 15–50 A — — — — 15–30 A — 200 A Max. Class J or T6 Fuses QO (B) EPD QO (B) EPE — — 400 A Max. Class T3 Fuses QO (B) QO (B) GFI QO (B) EPD QO (B) EPE 15–70 A 15–30 A 15–30 A — 200,000 200,000 d 2 Pole FI, KI, HR, JR 100,000 c 15–125 A 15–100 A 15–100 A — — 35–150 A 15–60 A 15–30 A 15–60 A 15–50 A 15–60 A 15–50 A — — — — 200,000 240/120 V 3P/4W b 1 Pole 15–70 A — — 15–30 A 15–30 A 15–30 A 15–20 A 15–20 A HL, JL 65,000 a Type 125,000 240/120 V 3P/4 208Y/120 3P/4W Square D™ Brand Branch Circuit Breaker Catalog Designation and Allowable Ampere Ranges cdef QO (B) QO (B) H QO (B) VH QO (B) PL QO (B) GFI QO (B) EPD QO (B) AFI QO (B) CAFI 15–30 A DJ, DG, DL 150–600 A 65,000 — Square D™ Brand Maximum Maximum Short Integral or Remote System Circuit Main Circuit Breakers Voltage Current and Remote Main AC ab Rating Fuses — — — 15–50 A 15–50 A 15–50 A 15–50 A 15–125 A 15–100 A 15–60 A — 15–60 A 15–50 A — 15–50 A For shown circuit breakers rated less than this maximum voltage, the indicated short circuit current rating also applies, but at the voltage rating of the circuit breaker. Short circuit tests are conducted at 100–105% of the maximum rated voltage of the panelboard. Suffixes HID, SWD, and SWN may also be applied to the applicable branch circuit breakers shown above. Suffix SWN may not be applied in combination with LC main breakers. Where QO (B) circuit breakers are shown above, QO (B) H, QO (B) VH, and QH (B) circuit breakers may also be used. Where QO (B) GFI circuit breakers are shown above, QO (B) EPD circuit breakers may also be used. To acheive selective coordiantion, the rating of the DJ main circuit breaker must be at least two times greater than the ampere rating of any branch circuit breaker. This page last modified 5/14/14 PANELBOARDS Square D™ Brand Maximum Maximum Short Integral or Remote System Circuit Main Circuit Breakers Voltage Current and Remote Main AC ab Rating Fuses 9-43 9 Table 9.196: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical) NQ Merchandised Panelboards NQ Merchandised Accessories Class 1640 www.schneider-electric.us 9 Table 9.197: NQ SurgeLogic SurgeLoc Plug-on SPDab Voltage Part Number List $ Price Poles Occupied PANELBOARDS 80 kA SSP01BIA08PBQ1 4200. 100 kA SSP01BIA10PBQ1 4500. 120 kA SSP01BIA12PBQ1 4800. 120 / 240 V 12 160 kA SSP01BIA16PBQ1 5300. 200 kA SSP01BIA20PBQ1 6500. 240 kA SSP01BIA24PBQ1 7900. 80 kA SSP02BIA08PBQ1 4400. 100 kA SSP02BIA10PBQ1 4700. 120 kA SSP02BIA12PBQ1 5100. 208 Y / 120 V 12 160 kA SSP02BIA16PBQ1 5550. 200 kA SSP02BIA20PBQ1 7000. 240 kA SSP02BIA24PBQ1 8250. 80 kA SSP03BIA08PBQ1 4400. 100 kA SSP03BIA10PBQ1 4700. 120 kA SSP03BIA12PBQ1 5100. 240 / 120 HLD 12 160 kA SSP03BIA16PBQ1 5550. 200 kA SSP03BIA20PBQ1 7000. 240 kA SSP03BIA24PBQ1 8250. a When selecting a panelboard with SurgeLoc SPD, an additional 12 circuit positions (6 adjacent mounting spaces per side) are occupied. For example, if the desired number of circuits is 30, refer to Digest Table 9.9 on page 6 and Table 9.10 on page 7 to select the NQ442L2/NQ442L2C interior and corresponding Box and Trim. b SPD is only available up to 72 desired circuit counts. 9-44 © 2012 Schneider Electric All Rights Reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:06:02 10:56:14-04:00 Modify Date : 2014:06:02 10:56:14-04:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:06:02 10:56:14-04:00 Format : application/pdf Document ID : uuid:790eea13-29f4-480d-8f3f-3295b7e0ecdc Instance ID : uuid:29bd570f-b76b-4997-8d10-8332598c714e Page Mode : UseOutlines Page Count : 44EXIF Metadata provided by EXIF.tools