108265 Catalog
118074-Attachment 118074-Attachment 118074-Attachment 785901 Batch6 unilog cesco-content
119478-Catalog 119478-Catalog 119478-Catalog 785901 Batch7 unilog cesco-content
106007-Catalog 106007-Catalog 106007-Catalog 785901 Batch8 unilog cesco-content
2014-07-05
: Pdf 108265-Catalog 108265-Catalog 785901 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 44
- Table of Contents
- Panelboards
- Series Ratings
- NQ and NF Panelboards
- NQ Merchandised Panelboards
- NQ Merchandised Panelboards
- QOB Bolt-On Circuit Breakers l
- NQ Factory Assembled Panelboards
- NF Merchandised Panelboards
- Circuit Breakers
- NF Factory Assembled Panelboards a
- NQ/NF Merchandised Single Row (Column Width) Panelboards
- NQ/NF Factory Assembled Single Row (Column Width) Panelboards
- I-Line™ and QMB Panelboards
- I-Line™ Merchandised Panelboards
- Circuit Breakers F-frame, PowerPact D-frame for I-Line™ Panelboards and Switchboards
- Class 650, 651
- PowerPact™ D-frame Mission Critical Circuit Breakers
- F-frame, PowerPact Q-frame for I-Line™ Panelboards and Switchboards
- H- and J-frame for I-Line™ Panelboards and Switchboards
- K-, PowerPact H-, J-, L-frame for I-Line™ Panelboards and Switchboards
- LA Mission Critical for I-Line™ Panelboards and Switchboards
- L- and PowerPact M-frame for I-Line™ Panelboards and Switchboards
- PowerPact P- and R-frame for I-Line™ Panelboards and Switchboards
- I-Line™ Factory Assembled Panelboards
- QMB Fusible Branch Switches
- QMB Factory Assembled Panelboards Fusible—600 Vac, 250 Vdc
- Modifications for Factory Assembled Panelboards
- Panelboards
- I-Line™ and QMB
- I-Line™ Combo Panelboard
- Series Ratings
- Series Ratings
- NQ Merchandised Panelboards
9-1
© 2012 Schneider Electric
All Rights Reserved
9PANELBOARDS
Table of Contents
Section 9
Panelboards
, x
NQ Panelboards
Page 9-5
NF Panelboards
Page 9-13
I-Line Panelboards
Page 9-20
QMB Panelboards
Page 9-35
Series Rated / Fully Rated Tables
NQ 9-2, 9-42
NF 9-3
I-Line™ 9-3
Lighting and Appliance Panelboards
NQ/NF Pricing Procedure 9-5
NQ Merchandised Main Lug Panelboards 9-6
Merchandised Main Circuit Breaker Panelboards 9-7
Merchandised 14-inch-wide Panelboards 9-8
Merchandised Accessories 9-9
QOB Branch Circuit Breakers 9-10
Factory Assembled Panelboards and Circuit Breakers 9-11
Factory Assembled Common Features 9-12
NF Merchandised Main Lugs Panelboards 9-13
Merchandised Main Circuit Breaker Panelboards 9-13
Merchandised Main Lug and Main Circuit Breaker Panelboards with 9-13
Merchandised Accessories 9-14
EDB, EGB, EJB Branch Circuit Breakers 9-15
Factory Assembled Panelboards 9-16
Factory Assembled Common Features 9-17
NQ/NF
Column Width
Merchandised Single Row (Column Width) Panelboards
Factory Assembled Single Row (Column Width) Panelboards
9-18
9-19
Power Distribution Panelboards—Circuit Breaker Type
I-Line/QMB Pricing Procedure 9-20
I-Line Merchandised Panelboards (HCN, HCM, HCP-SU) 9-21
Merchandised Panelboards (HCP, HCR-U) 9-22
Merchandised Accessories 9-23
Circuit Breakers 9-24
F-frame Circuit Breakers 9-24
Q-frame Circuit Breakers 9-25
H-frame and J-frame Circuit Breakers 9-26
K-frame Circuit Breakers 9-27
L-frame Circuit Breakers 9-28
M-frame Circuit Breakers 9-29
P-frame and R-frame Circuit Breakers 9-30
Factory Assembled Pricing 9-31
Factory Assembled Branch Circuit Breakers 9-32
Factory Assembled Common Features 9-34
Power Distribution Panelboards—Fusible Type
QMB Replacement Switches 9-35
Factory Assembled Pricing 9-36
Factory Assembled SPD Units 9-37
Panelboard Special Features
Factory Assembled Modifications 9-38
Terminal Data 9-39
www.schneider-electric.us
9PANELBOARDS
9-2 © 2012 Schneider Electric
All Rights Reserved
Series Ratings NQ Panelboards
Class 1640
This page contains UL Tested and Certified series combination ratings for
panelboards. These ratings apply to either an integral main located in the
same enclosure or a remote main located in a separate enclosure.
NOTE: Table 9.1 NQ Series Connected Circuit Breaker Ratings
table has moved to page 9-42 and page 9-43.
Table 9.1: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Maximum
System
Voltage
AC ab
Maximum
Short
Circuit
Current
Rating
Square D™ Brand
Integral or Remote
Main Circuit Breakers
and Remote Main
Fuses
Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef
Type 1 Pole 2 Pole 3 Pole
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-3
Series Ratings NF and I-Line™ Panelboards
Class 2110 / Refer to Catalog 2110CT9701
This page contains UL Tested and Certified series combination ratings for
panelboards. These ratings apply to either an integral main located in the
same enclosure or a remote main located in a separate enclosure.
.
aShort circuit tests are conducted at 100–105% of the maximum rated voltage of the
panelboard.
bObsolete. Contact your local Schneider Electric representative or distributor for the
replacement circuit breaker.
NOTE: LD, LG, LH, and LL breakers are only available in 3 pole
configurations.
Table 9.2: NF Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Maximum
System
Vol tage,
AC a
Max.
Short
Circuit
Current
Rating
Square D™ Brand
Integral or Remote
Main Circuit Breakers and
Remote Main Fuses
Square D™ Brand
Branch Circuit Breaker Catalog
Designation and Allowable
Ampere Ranges
120
120/240
240
65,000 EG, FH, FG, KH, LH, MH, MX, HG, JG, DG EDB, EDB-EPD
LG EDB
EG ECB-G3
100,000 EJ, FC, FJ, KC, LC, HJ, JJ EDB, EDB-EPD, EGB
DJ, LJ EDB, EGB
EJ, FC, KC, HJ, JJ ECB-G3
125,000 HL, JL EDB, EDB-EPD, EGB, ECB-G3
200,000 FI, KI, LI, LXI, HR, JR, LR EDB, EDB-EPD, EGB, EJB
FI, KI, HR, JR ECB-G3
Class J or T (600 V) 200 A Max Fuses ECB-G3
277
480Y/277
35,000 EG, FG, KH, LH, HG, JG, DG, LG EDB, EDB-EPD
EG, HG, JG ECB-G3
65,000
EJ, FC, FJ, KC, LC, LX, HJ, JJ, DJ EDB, EDB-EPD, EGB
EJ, FC, KC, HJ, JJ ECB-G3
LJ EDB, EDB-EPD, EGB,
EGB-EPD
LL EDB-EPD, EGB-EPD
100,000 HL, JL EDB, EDB-EPD, EGB, EJB
DL, LL EDB, EGB, EJB
400 A Max Fuses EDB, EDB-EPD, EGB, EJB
200,000
FI, KI, LI, LXI, HR, JR, LR EDB, EDB-EPD, EGB, EJB
FI, KI, HR, JR ECB-G3
200 A Max Fuses EDB, EDB-EPD, EGB, EJB, ECB-G3
600Y/347
18,000 HG, JG, MG, EDB
LG EDB (15–110 A)
25,000
EJ, FI, KH, KI, LC, LE, LX, LI, LXI, HJ, JJ EDB, EGB
LJ EDB (15–110 A),
EGB (15–110 A)
LH (15–70 A) EDB, EGB
35,000 LC, LE, LX EDB, EGB, EJB
50,000
HL, JL, EDB, EGB, EJB
LL EDB (15–110 A), EGB
(15–110 A),EJB (15–110 A)
65,000 FI, KI, HR, JR EDB, EGB, EJB
LI, LXI, LR EJB
200,000 Class J or T (600 V) 200 A Max Fuses EDB, EGB, EJB
Table 9.3: I-Line Series Connected Circuit Breaker Ratings
(RMS Symmetrical)
Maximum
System
Voltage
AC a
Max. Short
Circuit
Current
Rating
(RMS
Symm.)
Integral or Remote
2- or 3-pole Main
Circuit Breaker
Square D™ Brand Branch Circuit Breakers
Designation Poles
120
42k MG FY
1
65k QG, LH FA, FDb
100k FJb, QJ FDb
QJ, LC FA
LJ FH
200k LR FH, FY
208Y/120 100k QJ FA, FDb2, 3
QJ, PH, PJ, RJ QD, QG
240
35k MG FA 1
42k KA FDb1, 2, 3
LA, MA HD, JD, QD 2, 3
50k MG FA
MG FA (25 A Max.) 1
65k
HG, JG FA, HD
2, 3
JG JD, QD
QG FA, FDb, QD
LH, MH, PA, PG, RG HD, JD, QD
FGb, FH, MH, MX, PJ FDb
1, 2, 3FC, KC, KH, LC, LH FDb, FGb
LH FA
LH LA
2, 3
MG HD, JD, KA
LG HD, JD, KA, LA, LD, MA
DG FH, HD, JD, KA, LA, MA
85k RL FH, KH
100k
FC, KC, LC, LX FDb, FGb, FJ 1
PH, PJ, RJ QD, QG 2, 3
QJ FDb2
FJbFDb
2, 3
FC, KC FA, FH, FDb, FGb, FJb
LC, LX FH, FDb, FGb, FJb
KC, LC, LX KA
KC, LC KH
LC LA, LH, MG
LC FA 1, 2, 3
HJ, JJ FA, FH, HD, HG
2, 3
JJ JD, JG
LC, LX, MJ, PJ, RJ HD, HG, JD, JG
MJ LA, LH
LJ FH, HD, HG, JD, JG, KA, LA, LD, LG, MA, MG
DJ FH, HD, HG, JD, JG, KA, LA, MA, MG
RL RG
HL, JL HD, HG, HJ, FA, H
240 125k
JL JD, JG, JJ
2, 3
PC, PH, PL, RL HD, HG, JD, JG
PC, PL, RL HH, JJ
FI, KI, LI, LXI HD, HG, HJ
KI, LI, LXI JD, JG, JJ
240 200k
FI, KI, LI, LXI FDb, FGb, FJ 1
FI, KI FA, FH, FC, FDb, FGb, FJb
2, 3
LI, LXI FH, FDb, FGb, FJb
LI FC
KI, LI, LXI KA, QD, QG, QJ
LI KC
LR FH, HJ, HL, JJ, JL, LA, LH, QD, QG, QJ
277
18k LD FY
1
25k FH, KA FDb
35k FGb, KH, LH FDb
DG FH, FY
LG FH, FY
65k
FJbFDb
FC, KC FA, FH, FY, FDb, FGb
LC, LX (400 A Max.) FH
LC, LX (600 A Max.) FY, FDb, FGb
LJ FH, FY
DJ FH, FY
LL FY
100k DL FH, FJb
LL FH, FJb
200k
FI, KI FA, FH, FY, FDb, FGb, FJb
HR FA, FJb, FY
JR FA, FJb, FY
LI, LXI (400 A Max.) FH
LI, LXI (600 A Max.) FY, FDb, FGb, FJb
LR FH, FY
480
22k MG FA
2, 3
30k
KH, LA, MA, MX, PA,
PC, PX, PJ FH
LA, MA, PA, PC, PX KA
LA, MA, PA HD, JD
MG FA (25 A Max.), FH, KA
35k
MH, MX, PA HD, JD
HG, JG FA, HD
JG JD
LH, MG, PG, RG HD, JD
LG FH, HD, JD, KA, LA, LD, MA
DG FH, HD, JD, KA, LA, MA
42k MJ FH (25 A Max.)
RL RG
50k MJ KA, KH
65k
FC, KC FA, FH
HJ, JJ FA, FH, HD, HG
JJ JD, JG
LC, LI, LX, LXI HD, HG, JD, JG
LC, LX (400 A Max.) FH
KC, LC, LX KA
LC, LX LA
LJ FH, HD, HG, JD, JG, KA, LA, LD, LG, MA
DJ FH, HD, HG, JD, JG, KA, LA, MA
100k
HL, JL FA, FH, HD, HG, HJ
JL JD, JG, JJ
JR FA
LI, LXI (600 A Max.) KA
LL FH, HD, HG, HJ, JD, JG, JJ, KA, LA, LD, LG,
LJ, MA
DL FH, HD, HG, HJ, JD, JG, JJ, KA, LA, MA
PC, PH, PL, RL HJ, JJ
RL RG
200k
FI, KI FA, FH, FC, HD, HG, HJ
HR FA, HD, HG, HJ, HL
JR HD, HG, HJ, HL, JD, JG, JJ, JL
KI JD, JG, JJ, KA
LI FC, KA, KC, LA, HJ, HL, JJ, JL
LR FH, HJ, HL, JJ, JL, LA, LH
LXI KA, HJ, HL, JJ, JL
480Y/277
25k FH, KA FDb
35k FGb, KH, LH FDb
65k
FJbFDb
FC, KC FDb, FGb
LC, LX (600 A Max.) FDb, FGb
200k FI, KI FDb, FGb, FJb
LI, LXI (600 A Max.) FDb, FGb, FJb
600
18k
HG, JG FA, HD
2, 3
JG JD
LG HD, JD, LD
MG, PG, RG HD, JD
MG FA
25k
HJ, JJ FA, HD, HG
JJ JD
LJ HD, HG, JD, JG, LD, LG, MA
PJ, RJ MG
35k LC FH, HD, HG, HJ, JD, JG, JJ, LA
50k
HL, JL FA, HD, HG, HJ
JL JD, JG, JJ
LL HD, HG, HJ, JD, JG, JJ, LD, LG, LJ, MA
PK HJ, JJ, MJ
100k
FI, KI HD, HG, HJ
HR FA, HD, HG, HJ, HL
JR FA, HD, HG, HJ, HL, JD, JG, JJ, JL
KI JD, JG, JJ
KI, LI FH
LI LA
600Y/347 18k MG FA (25 A max.) 125k MJ FA (30 A max.)
50k HL, JL FJ
Table 9.3: I-Line Series Connected Circuit Breaker Ratings
(RMS Symmetrical) (continued)
Maximum
System
Voltage
AC a
Max. Short
Circuit
Current
Rating
(RMS
Symm.)
Integral or Remote
2- or 3-pole Main
Circuit Breaker
Square D™ Brand Branch Circuit Breakers
Designation Poles
9-4 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
9PANELBOARDS
Series Ratings I-Line™ Panelboards
Class 2110
aSeries rating valid for 2-pole or 3-pole circuit breakers.
Note:
•The fuse used in this UL test is an envelope (umbrella) fuse. This fuse is designed as a “worst case’’ fuse. Thus, no matter what manufacturer’s fuse is used,
the Square D™ brand circuit breaker is protected.
•The line side fused switch may be in a separate enclosure or in the same enclosure as the loadside circuit breaker. A line side fused switch may be a
submain, integral main, or remote main. A load side circuit breaker may be a branch, submain, or an integral main used on the load side of a remote main.
This series combination short circuit current rating shall not exceed that of the line side fused switch. The charts apply to Square D™ brand load side circuit
breakers only. However, the line side fuse ratings are independent of the fuse manufacturer.
•Not applicable to Corner Grounded Systems.
•Limiters used in Square D™ brand DSL and DSL II fused power circuit breakers are not class L fuses and do not have series ratings.
Table 9.4: Fuse/I-Line Circuit Breaker Series Connected Ratings
Maximum System
Voltage AC
Max. Short Circuit
Current Rating
(RMS Symm.)
Remote Main Fuse Square D™ Brand Branch Circuit Breakers
Maximum
Amperage Fuse Class Designation a
120/240 1Ø
208Y/120 100,000
1200 A L, T (300 V) QD, QG
800 A T (600 V) QD, QG
600 A J, RK5 QD, QG
240 65,000
1200 A L, T (300 V) QD
800 A T (600 V) QD
600 A J, RK5 QD
240 100,000
1200 A L, T (300 V) QD, QG (2-pole)
800 A T (600 V) QD, QG (2-pole)
600 A
J, RK5 QD, QG (2-pole)
L, T (600 V) FA, FH, KA, KH, KC, LA, LH, MA, MH, MX, PG
RK5 FH, KA, KH, LA, LH, MA, MH, MX, PG, HD, HG, HJ, HL, JD, JG, JJ, JL
J HD, HG, HJ, HL, JD, JG, JJ, JL
800 A
T (600 V) FH, KA, KH, LA, LH, MA, MH, MX, PG
T (300 V) PG
L FH,KA,KH,LA,LH,MA,MH,MX,PG
1200 A L FH, KH, LA, LH, MA, MH, MX, PG
T (600 V) HD, HG, HJ, HL, JD, JG, JJ, JL
1600/2000 A L KH, MA, MH, MX, PG
4000 A L HD, HG, HJ, HL, JD, JG, JJ, JL
240 200,000
600 A
J, T (600 V) FA( 3-pole only), FH, FC, KA, KH, KC, LA, LH, LC,
MA,MH,MX,NA,NC,NX,PG,PJ,PL
RK5 FH, FC, HD, HG, HJ, HL, JD, JG, JJ, JL KH, KC, LA, LH, LC,
MA, MH, MX, NC, NX, PG, PJ, PL
J HD, HG, HJ, HL, JD, JG, JJ, JL
800 A
T (600 V) FH, FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
T (300 V) PG, PJ, PL
L FH,FC, KH, KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
1200 A L FC, KH, KC, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
T (600 V) HD, HG, HJ, HL, JD, JG, JJ, JL
1600/2000 A L NA, NC, NX, PJ, PL
4000 A L HD, HG, HJ, HL, JD, JG, JJ, JL
480 100,000
400 A J, T (600 V) HD, HG, HJ, HL, JD, JG, JJ, JL
600 A
J, RK5 HJ, HL, JJ, JL
J, T (600 V) FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
RK5 FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
800 A L, T (600 V) FC, KA, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
1200 A L FC, KH, KC, LA, LH, LC, MA, MH, MX, NA, PG, PJ
T (600 V) HJ, HL, JJ, JL
1600 A L KC, LC, MA, MH, MX, NA, PG, PJ
2000 A L KC, LC, MH,MG, MJ, MX, NA, PG, PJ
4000 A L HJ, HL, JJ, JL
480 200,000
200 A RK5 HJ, HL
400 A JFA, FH, FC, HJ, HL, JJ, JL, KA, KH, KC, LA, LH, LC,
MA,MH,MX,NA,NC,NX,PG,PJ, PL
T(600V) FA, FH, FC, HJ, HL, JJ, JL, KA, KH, KC, LA, LH, MA, MH, MX, NA, NC, NX
600 A
JFC, KA, KH, KC, LA, LH, LC, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL
T (600V) KA, KH, KC, LA, LH, MA, MH, MX, NA, NC, NX
RK5 KC, LA, LH, LC, MA, MH, MX, MG, MJ, NC, NX, PG, PJ,
800 A
T (300 V) PG, PJ, PL
T (600 V) KA, KH, KC, LA, LH, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL
L KC, LA, LH, LC, MA, MH, MX, NA, NC, NX, PG, PJ, PL
1200 A L KC, LC, MA, MH, MX, MG, MJ, NA, NC, NX, PG, PJ, PL
1600/2000 A L NA, NC, NX
600 100,000
30 A CC HG, JG ( molded case switches )
200 A J HD, HG, HJ, HL, JD, JG, JJ, JL
400 A J, T (600 V) HJ, HL, JJ, JL
600 A R MG, MJ
1200 A L MG, MJ
600 200,000 600 A J MG, MJ
800 A T (600 V) MG, MJ
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-5
NQ and NF Panelboards Pricing Procedure and Examples
Classes 1640 and 1670 / Refer to Catalog 1670CT0701, 1640CT0801
NQ and NF Merchandised Pricing Procedure
1. List circuit breakers required, either plug-on or bolt-on. See the
appropriate Digest pages for catalog numbers.
2. Determine equivalent number of pole spaces required.
3. Select proper main lug interior (from page 9-6) or main lug interior and
main circuit breaker adapter kit (from page 9-7) based on equivalent
number of poles and ampere rating. Interiors include solid neutral and
are field convertible to top-feed.
4. Select enclosure from appropriate page.
Type 1—Select box and front catalog number corresponding to interior
catalog number.
Type 3R, 5, 12—Select enclosure. Interior trim kit for Type 3R, 5, 12 is
included with the enclosure.
5. For complete price, add the component prices. Include panelboard
accessories.
6. Apply appropriate discount schedule.
NQ Merchandised Pricing Example
NF Merchandised Pricing Example
NQ and NF Factory Assembled Pricing Procedure
1. Select Base Price for main lugs or main circuit breaker from the Base
Price Table. Include equipment ground bar when required.
2. List Branch Circuit Breakers (either plug-on or bolt-on) and determine
total spaces required. Select price from the Branch Circuit Breakers
Table. Include space-only charge for future requirements.
3. If total spaces required exceeds the maximum listed, price as two or
more panelboards and add price for sub-feed or feed-through lugs so
installer can cable between sections.
4. Add price for special features from appropriate page. Contact your local
Schneider Electric representative or distributor for additional special
features.
5. For complete price, add all prices. Order by description.
NOTE: Additional special price adders can be found in the
Supplemental and Obsolescence Digest, Section 4.
6. Apply appropriate discount schedule.
NQ Factory Assembled Pricing Example
NF Factory Assembled Pricing Example
Table 9.5: 208Y/120 Vac, 3Ø4W, 10 kA SCCR, 225 A, MLO, Type-1,
surface-mount, bolt-on, branch circuit breakers,
main sub-feed lugs
Branches Page No. Catalog Number Spaces $ Price
(20) 20/1 9-10 (20) QOB120 20 795.
two 40/2 9-10 two QOB240 4177.
two 30/3 9-10 two QOB330 6585.
Tota l 3 0
225 A MLO Interior 9-6 NQ430L2 – 1215.
Box 9-6 MH32 – 113.
Cover 9-6 NC32S – 527.
Sub-feed Lugs 9-6 NQSFL2 – 203.
Total Price 3615.
Table 9.6: 480Y/277 Vac, 3Ø4W, 25 kA SCCR, fully rated, copper bus, 100 A,
main circuit breaker, Type 1, flush-mount, bolt-on,
branch circuit breakers
Branches Page No. Catalog No. Spaces $ Price
(13) 20/1 9-15 EGB14020 13 3315.
one 40/2 9-15 EGB24040 2 776.
one 50/3 9-15 EGB34050 3 1131.
Total 18
Main circuit breaker adapter kit
(less circuit breaker) 9-13 N150MH – 780.
Main circuit breaker 7-28 HGL36100 – 1701.
125 A MLO Cu Bus Int. 9-13 NF418L1C – 1838.
Box 9-13 MH38 – 113.
Cover 9-13 NC38F – 549.
Total Price 10203.
Table 9.7: 208Y/120 Vac, 3Ø4W, 10 kA SCCR, 225 A, MLO, Type-1,
surface-mount, bolt-on, branch circuit breakers,
main sub-feed lugs
Item Page No. $ Price
225 A MLO Base Price 9-11 928.
(20) 20/1 Bolt-on 9-11 1360.
two 40/2 Bolt-on 9-11 268.
two 30/3 Bolt-on 9-11 704.
Sub-feed Lugs 9-12 128.
Total Price 3388.
Table 9.8: 480Y/277 Vac, 3Ø4W, 25 kA SCCR, fully rated, copper bus, 250 A,
main circuit breaker, Type 1, flush-mount, bolt-on,
branch circuit breakers
Item Page No. $ Price
250 A Main Circuit Breaker Base Price 9-16 6180.
Copper bus adder 9-17 458.
(13) 20/1 9-16 4212.
one 40/2 9-16 746.
one 50/3 9-16 1264.
Total Price 12860.
Example pricing only Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-6 © 2012 Schneider Electric
All Rights Reserved
NQ Merchandised
Panelboards
NQ Main Lug Interiors—240 Vac, 48 Vdc
Class 1640 / Refer to Catalog 1640CT0801
Table 9.9: Main Lug Interiors—Accepts plug-on and bolt-on circuit breakers
Pole
Spaces
Mains
Rating
Total Price Interior
Front and Enclosure
Interior Only
(Order Branch Circuit
Breakers Separately)
Type 1 Enclosure Type 3R, 5, 12 Enclosure f
Box
20 in. W x 5.75 in. D bMono-Flat™ Front cHinged Front Enclosure
20 in. W x 6.5 in. D Height
(In.)
Type 1 Type 3R,
5,12 Catalog No. a$Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price
20-inch-wide Cabinet g—Single Phase 3-Wire
18
100
1395. 2977. NQ18L1 785. MH26
113.
NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26
1474. 3056. NQ18L1C 864.
30 1585. 3149. NQ30L1 945. MH32 NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32
1675. 3239. NQ30L1C 1035.
30
225
1744. 3308. NQ30L2 1104. MH32
113.
NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32
1819. 3383. NQ30L2C 1179.
42 2002. 3556. NQ42L2 1340. MH38 NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38
2080. 3634. NQ42L2C 1418.
72d3073. 4900. NQ72L2 2297. MH44 NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44
3206. 5033. NQ72L2C 2430.
84d3521 5288. NQ84L2 2679. MH50 NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50
3677. 5444. NQ84L2C 2835.
30
400
2462. 4229. NQ30L4 1620.
MH50 113. NC50V ( ) 729. NC50V( )HR 912. MH50WP 2609. 50
2579. 4346. NQ30L4C 1737.
42 2620. 4387. NQ42L4 1778.
2738. 4505. NQ42L4C 1896.
84d4853. 6534. NQ84L4C 3792. MH68 NC68V ( ) 948. NC68V( )HR 1185. MH68WP 2742. 68
30
600
2705. 4548. NQ30L6C 1863. MH50 113. NC50V ( ) 729. NC50V( )HR 912. MH62WPe2685. 50/62
42 2861. 4704. NQ42L6C 2019.
84d5099. 6873. NQ84L6C 4038. MH68 NC68V ( ) 948. NC68V( )HR 1185. MH80WPe2835. 68/80
20-inch-wide Cabinet g —Three Phase 4-Wire
18
100
1486. 3068. NQ418L1 876. MH26
113.
NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26
1561. 3143. NQ418L1C 951.
30 1752. 3316. NQ430L1 1112. MH32 NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32
1831. 3395. NQ430L1C 1191.
30
225
1855. 3419. NQ430L2 1215. MH32
113.
NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32
1932. 3496. NQ430L2C 1292.
42 2138. 3692. NQ442L2 1476.
MH38 NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38
2213. 3767. NQ442L2C 1551.
54 2559. 4113. NQ454L2 1898.
2655. 4209. NQ454L2C 1994.
72d3307. 5134. NQ472L2 2531. MH44 NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44
3436. 5263. NQ472L2C 2660.
84d3794. 5561. NQ484L2 2952. MH50 NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50
3944. 5711. NQ484L2C 3102.
30
400
2704. 4471. NQ430L4 1862.
MH50
113.
NC50V ( ) 729. NC50V( )HR 912. MH50WP 2609. 50
2822. 4589. NQ430L4C 1980.
42 2854. 4621. NQ442L4 2012.
2975. 4742. NQ442L4C 2133.
72d4449. 6134. NQ472L4 3449. MH62 NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62
4657. 6342. NQ472L4C 3657.
84d5327. 7008. NQ484L4C 4266. MH68 NC68V ( ) 948. NC68V( )HR 1185 MH68WP 2742. 68
30
600
2983. 4826. NQ430L6C 2141. MH50 113. NC50V ( ) 729. NC50V( )HR 912. MH62WPe2685. 50/62
42 3116. 4959. NQ442L6C 2274.
84d5609. 7383. NQ484L6C 4548. MH68 NC68V ( ) 948. NC68V( )HR 1185. MH80WPe2835. 68/80
a“C’’ suffix indicates copper bussing.
bEmbossed mounting holes add a 0.25-inch standoff to back of MH box.
cAdd “F” for flush mount, “S” for surface mount.
dUse only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits.
eWhen NEMA 3R, 5, or 12 enclosures are selected, an NQ12RDE kit should also be selected. See Table 9.19.
fEnclosure includes trim kit.
gFor the NQ14-inch-wide panelboard offer, See Digest page 9-8.
PE1A Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-7
NQ Merchandised
Panelboards
NQ Main Circuit Breaker Interiors—240 Vac, 48 Vdc
Class 1640 / Refer to Catalog 1640CT0801
Table 9.10: Main Circuit Breaker Interiors—Will accept plug-on and bolt-on circuit breakers
Pole
Spaces
Mains
Rating
Total $ Price
Interior, Front,
Box and
Adapter Kit f
Interior Only
(Order Branch Circuit
Breakers Separately)
Main Circuit Breaker Adapter Kit
(Less Circuit Breaker) f
Type 1 Enclosure Type 3R, 5, 12 Enclosure e
Box
20 in. W x 5.75 in. D bMono-Flat™ Front Hinged Front Enclosure
20 in. W x 6.5in. D Height
(In.)
Type 1 Type 3R,
5, 12 Catalog No. a$ Price Catalog No. $ Price Circuit Breaker
Frame Size gCatalog No. $ Price Catalog
No. c$ Price Catalog No. $ Price Catalog
No. $ Price
20-inch-wide Cabinet h—Single Phase 3-Wire
16k100
back-
fed
1395. 2977. NQ18L1 785. ——
Select
QOB 2-pole or
QOB-VHi
MH26 113. NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26
1474. 3056. NQ18L1C 864. ——
28k1585. 3149. NQ30L1 945. —— MH32 113. NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32
1675. 3239. NQ30L1C 1035. ——
18 100 2227. 3781. NQ18L1 785. NQMB2HJ 780.
HD, HG, HJ, HLl
100A maximum
MH38 113. NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38
2306. 3860. NQ18L1C 864.
30 100 2501. 4328. NQ30L1 945. NQMB2HJ 780. MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44
2591. 4418. NQ30L1C 1035.
30 225 2660. 4487. NQ30L2 1104.
NQMB2HJ
NQMB2Q
NQMB2KI
780.
HD, HG, HJ, HLl
or JD, JG, JJ, JL
QB,QD,QG,QJ
KI
MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44
2735. 4562. NQ30L2C 1179.
42 225 2962. 4729. NQ42L2 1340. 780. MH50 113. NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50
3040. 4807. NQ42L2C 1418.
72d225 3976. 5729. NQ72L2 2297. 780. MH56 113. NC56 ( ) 786. NC56( )HR 983. MH56WP 2652. 56
4109. 5862. NQ72L2C 2430.
84d225 4459. 6144. NQ84L2 2679. 780. MH62 113. NC62 ( ) 887. NC62( )HR 1109. MH62WP 2685. 62
4615. 6300. NQ84L2C 2835.
30 400 3400. 5085. NQ30L4 1620. NQMB4LA 780. LA/LHmMH62 113. NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62
3517. 5202. NQ30L4C 1737.
42 400 3558. 5243. NQ42L4 1778. NQMB4LA 780. LA/LHmMH62 113. NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62
3676. 5361. NQ42L4C 1896.
84d400 5686. 7407. NQ84L4C 3792. NQMB4LA 780. LA/LHmMH80 113. NC80V ( ) 1001. NC80V( )HR 1245. MH80WP 2835. 80
20-inch-wide Cabinet h—Three Phase 4-Wire
15k100
back-
fed
1395. 2977. NQ418L1 785. ——
Select
QOB 3-pole or
QOB-VHj
MH26 113. NC26 ( ) 497. NC26( )HR 620. MH26WP 2192. 26
1474. 3056. NQ418L1C 864. ——
27k1585. 3149. NQ430L1 945. —— MH32 113. NC32 ( ) 527. NC32( )HR 657. MH32WP 2204. 32
1675. 3239. NQ430L1C 1035. ——
18
100
2318. 3872. NQ418L1 876.
NQMB2HJ 780. HD, HG, HJ, HL
100A maximum
MH38 113. NC38 ( ) 549. NC38( )HR 687. MH38WP 2216. 38
2393. 3947. NQ418L1C 951.
30 2668. 4495. NQ430L1 1112. MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44
2747. 4574. NQ430L1C 1191.
30
225
2771. 4598. NQ430L2 1215.
NQMB2HJ
NQMB2Q
NQMB2KI
780.
HD, HG, HJ, HL or
JD, JG, JJ, JL
QB,QD,QG,QJ
KI
MH44 113. NC44 ( ) 663. NC44( )HR 830. MH44WP 2603. 44
2848. 4675. NQ430L2C 1292.
42 3098. 4865. NQ442L2 1476.
780. MH50 113. NC50 ( ) 729. NC50( )HR 912. MH50WP 2609. 50
3173. 4940. NQ442L2C 1551.
54 3519. 5286. NQ454L2 1898.
3615. 5382. NQ454L2C 1994.
72d4210. 5963. NQ472L2 2531. 780. MH56 113. NC56 ( ) 786. NC56( )HR 983. MH56WP 2652. 56
4339. 6092. NQ472L2C 2660.
84d4732. 6417. NQ484L2 2952. 780. MH62 113. NC62 ( ) 887. NC62( )HR 1109. MH62WP 2685. 62
4882. 6567. NQ484L2C 3102.
30
400
3642. 5327. NQ430L4 1862.
NQMB4LA 780. LA/LHmMH62 113. NC62V ( ) 887. NC62V( )HR 1109. MH62WP 2685. 62
3760. 5445. NQ430L4C 1980.
42 3792. 5477. NQ442L4 2012.
3913. 5598. NQ442L4C 2133.
72d5314. 6986. NQ472L4 3449. NQMB4LA 780. LA/LHmMH74 113. NC74V ( ) 972. NC74V( )HR 1215. MH74WP 2757. 74
5522. 7194. NQ472L4C 3657.
84d6160. 7881. NQ484L4C 4266. NQMB4LA 780. LA/LHmMH80 113. NC80V ( ) 1001. NC80V( )HR 1245. MH80WP 2835. 80
a“C’’ suffix indicates copper bussing.
bEmbossed mounting holes add a 0.25 inch standoff to back of MH box.
cAdd “F” for flush mount, “S” for surface mount.
dUse only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits.
eEnclosure includes trim kit.
fSelect the appropriate main circuit breaker from the tables starting on Digest page 7-22 and add the circuit breaker price to the total price of the panelboard.
gCircuit breaker interrupt ratings, See the tables starting on Digest page 7-22.
hFor the NQ14-inch-wide panelboard offer, See Digest page 9-8.
iQOB2150VH takes four pole spaces; all other QOB two pole circuit breakers take two pole spaces.
jQOB3110VH to QOB3150VH take six pole spaces; all other QOB three pole circuit breakers take three pole spaces.
kPole spaces shown are available for branch circuits, with spaces deducted for the back fed main breaker.
lFor single phase applications, order a 3-pole breaker. Example: HDL36100.
mFor 400A applications, order short handle circuit breaker (LAL36400MB).
PE1A Discount
Schedule
www.schneider-electric.us
9-8 © 2012 Schneider Electric
All Rights Reserved
9PANELBOARDS
NQ Merchandised
Panelboards
NQ 14-inch-wide Panelboards
Class 1640
NQ 14-inch-wide—240 Vac, 48 Vdc
14-inch-wide NQ panelboards are now available for those customers whose equipment space is limited. Developed with
customer input, Square D™ brand NQ panelboards are built to last, featuring innovations for ease of installation and durability.
Features
•240 Vac, 48 Vdc maximum
•225 A maximum main circuit breaker or main lugs
•60 A maximum branch circuit breakers
•Visi-Trip™ indication on branch circuit breakers
•10,000–65,000 A Short Circuit Current Rating (SCCR)
•Interiors supplied with tin plated copper bus as standard
•Interiors accept bolt-on and plug-on branch circuit breakers
•Three-phase, four-wire, and single-phase, three-wire
interiors available
•Panelboards available with Mono-Flat™ front
•Suitable for use as service entrance equipment
•Branch circuit filler plates provide fast and easy
installation
•Both fully and series-rated systems are available
14-inch-wide NQ
Panelboard Main Lug
Main Breaker Panelboard
Main Lug Panelboard
Table 9.11: Main Lug Interiors—Accepts Plug-On and Bolt-On Branch Breakers
Max. Number
of Breakers
Main
Ratings
Total $ Price
Interior, Front, Box
and Adapter Kit
Interior Only (Order
Branch Circuit Breakers
Seperately)
Type 1 Enclosure
Box 14"W x 5.75" Db Mono Flat Front Hinged Front
Type 1 Type 3R ,
5, 12 Cat. No. $ Price Cat. No. $ Price Cat. No. b$ Price Cat. No. $ Price
14-inch-wide Cabinet—Single Phase 3-Wire
18 100 A 1407. —NQ18L1C14 951. NQB532 118. NQC32 338. N/A —
30 1647. —NQ30L1C14 1191. NQB532 118. NQC32 338. N/A —
30 225 A 1748. —NQ30L2C14 1292. NQB532 118. NQC32 338. N/A —
42 2028. —NQ42L2C14 1151. NQB538 118. NQC38 338. N/A —
14-inch-wide Cabinet—Three Phase 4-Wire
18 100 A 1407. —NQ418L1C14 951. NQB532 118. NQC32 338. N/A —
30 1647. —NQ430L1C14 1191. NQB532 118. NQC32 338. N/A —
30 225 A 1748. —NQ430L2C14 1292. NQB532 118. NQC32 338. N/A —
42 2028. —NQ442L2C14 1151. NQB538 118. NQC38 338. N/A —
Table 9.12: Main Circuit Breaker Interiors—Accepts Plug-On and Bolt-On Branch Breakers
Max.
Number
of
Breakers
Main
Ratings
Total $ Price
Interior, Front,
Box and
Adapter Kit
Interior Only (Order
Branch Circuit
Breakers Seperately)
Main Circuit Breaker Adapter Kit
(Less Circuit Breaker)
Type 1 Enclosure
Box 14"W x 5.75"
Db Mono Flat Front Hinged Front
Type 1
Type
3R, 5,
12
Cat. No. $
Price Cat. No $
Price Cat. No Cat. No.c$
Price Cat. No. b$
Price Cat. No. $
Price
14-inch-wide Cabinet—Single Phase 3-Wire
16 a
100
1407. —NQ18L1C14 951. — — Select QOB
2-pole or
QOB-VH
NQB532 118. NQC32 338. N/A —
28 a1647. —NQ30L1C14 1191. —— NQB532 118. NQC32 338. N/A —
30
225
1748. —NQ30L2C14 1292.
NQMB2HJ14
or
NQMB2Q14
780. HD, HG, HJ,
HL, OR JD,
JG, JJ, JL,
QB , QD,
QG, QJ
NQB544 118. NQC44 338. N/A —
42 2028. —NQ42L2C14 1151. 78. NQB550 118. NQC50 359. N/A —
14-inch-wide Cabinet—Three Phase 4-Wire
15 a
100
1407. —NQ418L1C14 951. — — Select QOB
3-pole or
QOB-VH
NQB532 118. NQC32 338. N/A —
27 a1647. —NQ430L1C14 1191. —— NQB532 118. NQC32 338. N/A —
30
225
1748. —NQ430L2C14 1292.
NQMB2HJ14
or
NQMB2Q14
780. HD, HG, HJ,
HL, OR JD,
JG, JJ, JL,
QB , QD,
QG, QJ
NQB544 118. NQC44 338. N/A —
42 2028. —NQ442L2C14 1151. 78. NQB550 118. NQC50 359. N/A —
aPole spaces shown are available for branch circuits, with spaces deducted for the back-fed main breaker.
bAdd “F” for flush mount, “S” for surface mount.
cAll 14” W boxes come with blank endwalls.
Table 9.13: NQ Accessories
Description Catalog No. $ Price Schedule
Equipment Ground Bars
Aluminum PK27GTA 33.80 DE3A
PK23GTA+ #1 to #4/0 Al or Cu lug PK23GTAL 40.70
Copper PK27GTACU 84.00 PE-1A
Ground Bar Insulator Kit PKGTAB 43.80 DE3A
Filler plate (15 per package) NQFP15d68.00 PE1A
Handle Attachments—Branch Circuit Breakers
Handle lock-off HLO1 9.90
DE2A
Handle tie - (QO and QOB only) QO1HT 3.80
Handle padlock attachment—1-pole QO1PA 10.70
2- and 3-pole QO1PL 10.70
Handle tie and lock-off for three 1-pole (QO, QOB) QO3HT 13.40
dFiller Plates are $3.00 each and must be ordered in packages of 15.
PE1A Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-9
NQ Merchandised
Panelboards
NQ Merchandised Accessories
Class 1640 / Refer to Catalog 1640CT0801
Table 9.14: NQ Merchandised Neutrals
Mains
Ampacity
200% Neutral Kit Copper 100% Neutral Kit
Catalog No. $ Price Box Add Schedule Catalog No. $ Price Box Add Schedule
100 NQNL1 315. no adder PE-1A NQN1CU 192. no adder PE-1A
225 NQNL2 or NQNL2ACCYb426. NQN2CU
400 NQNL4a639. no adder PE-1A NQN6CU 585. no adder PE-1A
600 Not Available NQN6CUa
aNot to be used with SFL, FTL, or SFB. These combinations are factory assembled only.
bFor 225A panel with SFL, FTL, or SFB, use NQNL2ACCY (enclosure size increases by 6 inches). Otherwise, use NQNL2.
Table 9.15: NQ Merchandised Sub-feed Lugs, Feed-through Lugs and Sub-feed Breakers
Mains
Ampacity
Sub-feed Lugs (N/A in MCB Interiors) Feed-through Lugs Sub-feed Circuit Breaker Kits (breaker not incl.)
Single SFB Two SFB
Catalog No. $ Price Schedule Catalog No. $ Price Schedule Catalog No. $ Price Schedule Catalog No. $ Price Schedule
100 A NQSFL1 155. PE-1A 100 A not available; —— — —————
225 A NQSFL2 203. PE-1A NQFTL2Lc476. PE-1A NQSFB2Q or
NQSFB2HJ 1029. PE-1A — — —
NQFTL2Hd
400 A NQSFL4 260. PE-1A NQFTL4Lc507. PE-1A Use the 2 SFB kit — NQSFB4Q or
NQSFB4HJ 1290. PE-1A
NQFTL4Hd
600 A Use FTL Factory Assembled Only
Note: See Table 9.16 and Table 9.17 for box selection table.
cThe final character L indicates the kit is used for Low circuit count interiors 30 and 42.
dThe final character H indicates the kit is used for High circuit count interiors 54, 72, and 84.
Table 9.16: Box Selection Table: Merchandised NQ Main Lug Panelboards
with Accessories
Feature
Circuits
Sub-feed Lugs Feed-through Lugs Sub-feed Circuit Breakers
100 A 225 A 400 A 600 A 100 A 225 A 400 A 600 A 100 A 225 A
(one)
400 A
(two)
600 A
(two)
18 MH26 — — Use FTL — — —
Factory
Asssembled
Only
———
Factory
Asssembled
Only
30 MH32 MH38 MH50 Use FTL Use
225A
Interior
MH38 MH50 — MH50 MH74
42 — MH44 MH50 Use FTL MH38 MH56 — MH56 MH74
72 — MH50 MH62 Use FTL MH50 MH68 — MH62 MH86
84 — MH56 MH68 Use FTL MH56 MH68 — MH68 e
e(c) Requires box longer than available box offer.
Table 9.17: Box Selection Table: Merchandised NQ Vertically Mounted Main
Breaker Panelboards w/ Accessories
Feature
Circuits
Feed-through Lugs Sub-feed Circuit Breakers
100 A 225 A 400 A 600 A 100 A 225 A
(one)
400 A
(two)
600 A
(two)
18———
Factory
Asssembled
Only
———
Factory
Asssembled
Only
30 — MH50 MH62 — MH62 MH86
42 — MH68 — MH68 MH86
72 — MH62 MH80 — MH74 f
84 — MH68 MH80 — MH80 f
f(c) Requires box longer than available box offer.
NOTE: NQ SurgeLogic SurgeLoc Plug-on SPD appears on page 9-44.
Table 9.18: NQ Optional Lugs
Ampacity AL Compression Lug Kit CU Mechanical Lug Kit CU Compression Kit
Catalog No. Lug Wire Range $ Price Catalog No. Lug Wire Range $ Price Catalog No. Lug Wire Range $ Price
100 NQALV1 one #8–1/0 AWG 117.00 NQCUM1 one #6–2/0 AWG 347.00 NQCUV1 one #6–1/0 AWG 345.00
225 NQALV2 one #4–300 kcmil 33.00 NQCUM2 one #6–250 kcmil NCQUV2 one 2/0–300 kcmil 417.00
400 NQALV4 two 2/0–500 kcmil 663.00 NQCUM4 one 1/0–750 kcmil
two 1/0–350 kcmil 636.00 NQCUV4 one 400–700 kcmil 767.00
600 NQALV6 two 2/0–500 kcmil 1208.00 NQCUM6 one 1/0–750 kcmil
two 1/0–350 kcmil 1139.00 NQCUV6 two 250–500 kcmil 1364.00
Table 9.19: NQ Accessories
Description Catalog No. $ Price Schedule
Sub-feed (Bolt-on)
2-pole QOB2125SL 176.00 DE2A
3-pole QOB3125SL 176.00
Equipment Ground Bars
Aluminum PK27GTA 33.80 DE3A
PK23GTA+ #1 to #4/0 Al or Cu lug PK23GTAL 40.70
Copper PK27GTACU 84.00 PE-1A
Ground Bar Insulator Kit PKGTAB 43.80 DE3A
Filler plate (15 per package) NQFP15g68.00 PE1A
Circuit I.D. Number Strips
1–102 odd/even (left side numbered 1,3,5 ...101) NQ102OE 7.90
PE1A
103–204 odd/even (left side numbered 103,105,107 ... 203) NQ204OE 7.90
1–102 sequential (left side numbered 1,2,3 ... 102) NQ102S 7.90
103–204 sequential (left side numbered 103,104,105 ... 204) NQ204S 7.90
Rail and Deadfront Extensions
6 in. Extension NQ6RDE 252.00
12 in. Extension NQ12RDE 283.00
18 in. Extension NQ18RDE 343.00
24 in. Extension NQ24RDE 397.00
Touch-up paint USAS #49 Gray (Aerosol can) PK49SP 39.00 DE1
Handle Attachments—Branch Circuit Breakers
Handle lock-off HLO1 9.90
DE2A
Handle tie - (QO and QOB only) QO1HT 3.80
Handle padlock attachment—1-pole QO1PA 10.70
2- and 3-pole QO1PL 10.70
Handle tie and lock-off for three 1-pole (QO, QOB) QO3HT 13.40
Handle tie for two 10–30 A single pole QO(B) circuit breaker QOHT2 10.90 DE2
Handle tie for three 10–30 A single pole QO(B) circuit breaker QOHT3 12.80
Handle Padlock Attachment for Padlocking in OFF position
For padlocking 1P QO circuit breaker in OFF position only, fixed attachment QO1PAF 43.50
DE2E
For padlocking 2P and 3P QO circuit breaker in OFF position only, fixed attachment QO2PAF 25.80
For padlocking 1P QO-GFI, QO-AFI, QO-CAFI, and QO-EPD circuit breakers in OFF position only, fixed attachment QOGFI1PAF 51.00
For padlocking 2P QO-GFI and QO-EPD circuit breakers in OFF position only, fixed attachment QOGFI2PAF 38.40
Neutral or Ground Lugs
#10 to #2 Al or #14 to #4 Cu QO70AN 9.90
DE3A#4 to #1/0 Al or Cu Q1100AN 11.10
#1 to #4/0 Al or Cu Q1150AN 32.40
Endwalls for MH Enclosures
Blank (one per package) 8011010501 41.10 PE1A
With Knockouts (one per package) 8011010401 41.10
gFiller Plates are $4.50 each and must be ordered in packages of 15.
PE1A DE2A DE2E DE3A Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-10 © 2012 Schneider Electric
All Rights Reserved
QOB Bolt-On
Circuit Breakers l
With Visi-Trip™ Indicator for NQ Panelboards
Class 690, 730, 910, 950
Table 9.20: QOB-GFI, QOB-EPD, and QOB-EPE Circuit Breakers
Ampere
Rating a
One-pole Two-pole—
Common Trip Three-pole—Common Trip
Catalog No. $
Price Catalog No. $
Price Catalog No. $
Price Catalog No. $
Price
QOB-GFI—QOB Qwik-Gard™ Circuit Breaker With Ground Fault Circuit Interrupter—
UL Class A 4–6 mA People Protection. b
120 Vac—10 k AIR 120/240 Vac—
10 k AIR
208Y/120 Vac—
10 k AIR
15 A QOB115GFI 248. QOB215GFI 444. QOB315GFI 791.
20 A QOB120GFI 248. QOB220GFI 444. QOB320GFI 791.
25 A QOB125GFI 248. QOB225GFI 444. ——
30 A QOB130GFI 248. QOB230GFI 444. QOB330GFI 791.
40 A — — QOB240GFI 444. QOB340GFI 791.
50 A — — QOB250GFI 444. QOB350GFI 791.
60 A — — QOB260GFIc444. ——
QOB-VHGFI d
120 Vac—22 k AIR
15 A QOB115VHGFI 497.
20 A QOB120VHGFI 497.
25 A QOB125VHGFI 497.
30 A QOB130VHGFI 497.
QOB-EPD—QOB Equipment protection circuit breakers
with UL Listed 30 mA (EPD) or 100 mA (EPE) equipment protection.
120 Vac—10 k AIR 120/240 Vac—
10 k AIR 240 Vac—10 k AIR
15 A QOB115EPD 417. QOB215EPD 671. QOB315EPDm1077. QOB315EPEm1077.
20 A QOB120EPD 417. QOB220EPD 671. QOB320EPDm1077. QOB320EPE 1077.
25 A QOB125EPD 417. QOB225EPD 671. ————
30 A QOB130EPD 417. QOB230EPD 671. QOB330EPDm1077. QOB330EPEm1077.
40 A — — QOB240EPD 671. QOB340EPDm1077. QOB340EPEm1077.
50 A — — QOB250EPD 671. QOB350EPDm1077. QOB350EPEm1077.
60 A — — QOB260EPD 671. ————
QOB-VHEPD
120 Vac—22 k AIR
15 A QOB115VHEPD 772.
20 A QOB120VHEPD 772.
25 A QOB125VHEPD 772.
30 A QOB130VHEPD 772.
QOB-HM—High magnetic trip circuit breakers
15 A QOB115HMe39.80
20 A QOB120HMe
QOB-K—Key operated QOB circuit breakers f
120 Vac—10 k AIR
10 A QOB110K 168.
15 A QOB115K 168.
20 A QOB120K 168.
25 A QOB125K 168.
30 A QOB130K 168.
(Footnotes for Tables 9.20, 9.21, and 9.22)
a10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors. 35–60 A
circuit breakers are suitable for use with 75 °C conductors.
bDo not connect to more than 250 feet of load conductor for the total one-way run to
prevent nuisance tripping.
cSuitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load
neutral connection.
dRecommended for applications where high initial inrush may occur and for individual
dimmer applications.
eUL Listed as SWD (switching duty) rated suitable for switching 120 Vac fluorescent
lighting loads.
fAvailable in single pole construction and can be mounted in any single pole space
which will accept a standard QOB. These circuit breakers can be turned ON or OFF or
RESET with a special key (Catalog No. QOK10) included with the circuit breaker.
These circuit breakers are UL Listed and available as shown in the table.
gUL Listed for use on circuit feeding fluorescent and High Intensity Discharge (HID)
lighting systems such as mercury vapor, metal halide, or high pressure sodium. These
circuit breakers are physically interchangeable with QOB circuit breakers.
hUL Listed 5,000 AIR on 3Ø corner grounded delta systems.
iUL Listed as HACR type for use with air conditioning, heating, and refrigeration
equipment having motor group combinations and marked for use with HACR type
circuit breakers.
jDC Rating is not available on indicated products.
kQOB2150VH uses 4 pole spaces. QOB3110VH, QOB3125VH, and QOB3150VH
each use 6 pole spaces. 40A maximum circuit breaker mounted opposite. Use with
75 °C wire only.
lFor QO plug-on circuit breaker pricing, see the tables starting on Digest page 1–2.
mSee note in Instruction Bulletin when using in an enclosure with a QO403 or QON
prefix.
Table 9.21: Standard Interrupting QOB 10,000 AIR Circuit Breakers
Ampere
Rating a
One-pole Two-pole—Common
Trip
Two-pole—
Common Trip h
Three-pole—
Common Trip
Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price
QOB Bolt-On
120 Vac—10 k AIR
48 Vdc—5 k AIR
120/240 Vac—10 k AIR
48 Vdc—5 k AIR j
240 Vac—
10 k AIR
240 Vac—10 k AIR
48 Vdc—5 k AIR j
10 A QOB110 39.80 QOB210 89. ——QOB310 293.
15 A QOB115 ie 39.80 QOB215 i89. QOB215H 240. QOB315 i293.
20 A QOB120 ie 39.80 QOB220 i89. QOB220H 240. QOB320i293.
25 A QOB125 i39.80 QOB225 i89. QOB225H 240. QOB325i293.
30 A QOB130 i39.80 QOB230 i89. QOB230H 240. QOB330i293.
35 A QOB135 i39.80 QOB235 i89. ——QOB335i293.
40 A QOB140 i39.80 QOB240 i89. QOB240H 240. QOB340i293.
45 A QOB145 i39.80 QOB245 i89. ——QOB345i293.
50 A QOB150 i39.80 QOB250i89. QOB250H 240. QOB350i293.
60 A QOB160 i39.80 QOB260 i89. QOB260H 240. QOB360i293.
70 A QOB170 i78. QOB270 i168. QOB270H 308. QOB370 ij 369.
80 A — — QOB280 ij 240. QOB280H 366. QOB380 ij 419.
90 A — — QOB290 ij 240. QOB290H 366. QOB390 ij 419.
100 A — — QOB2100ij 240. QOB2100H 366. QOB3100 ij 419.
110 A — — QOB2110ij 501. ——— —
125 A — — QOB2125ij 501. ——— —
Molded Case Switch 60 A max—
240 Vac QOB200 89. ——QOB300 293.
Molded Case Switch 100 A max—
240 Vac QOB2000 234. ——QOB3000 507.
Table 9.22: High Interrupting QOB and Specialty Circuit Breakers
Ampere
Rating a
One-pole Two-pole—Common Trip Three-pole—Common Trip
Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price
QOB-VH
120 Vac—22 k AIR 120/240 Vac —22 k AIR 240 Vac—22 k AIR
15 A QOB115VHie 72. QOB215VHi171. QOB315VHi440.
20 A QOB120VHie 72. QOB220VHi171. QOB320VHi440.
25 A QOB125VHi72. QOB225VHi171. QOB325VHi440.
30 A QOB130VHi72. QOB230VHi171. QOB330VHi440.
40 A QOB140VH 86. QOB240VHi171. QOB340VHi440.
50 A QOB150VH 86. QOB250VHi171. QOB350VHi440.
60 A QOB160VH 86. QOB260VHi171. QOB360VHi440.
70 A QOB170VH 137. QOB270VHi273. QOB370VHi560.
80 A — — QOB280VHi384. QOB380VHi629.
90 A — — QOB290VHi384. QOB390VHi629.
100 A — — QOB2100VHi384. QOB3100VHi629.
110 A — — QOB2110VHi1110. QOB3110VH k1809.
125 A — — QOB2125VHi1110. QOB3125VH k1809.
150 A — — QOB2150VH k1223. QOB3150VH k1809.
QHB
120 Vac—65 k AIR 120 Vac/240 Vac—65 k AIR 240 Vac—65 k AIR
15 A QHB115ie 122. QHB215i342. QHB315i596.
20 A QHB120ie 122. QHB220i342. QHB320i596.
25 A QHB125i122. QHB225i342. QHB325i596.
30 A QHB130i122. QHB230i342. QHB330i596.
QOB-HID—HID circuit breakers g
120 Vac—10 k AIR 120/240 Vac—10 k AIR 240 Vac—10 k AIR
15 A QOB115HIDe49.50 QOB215HID 108. QOB315HID 327.
20 A QOB120HID e49.50 QOB220HID 108. QOB320HID 327.
25 A QOB125HID 49.50 QOB225HID 108. QOB325HID 327.
30 A QOB130HID 49.50 QOB230HID 108. QOB330HID 327.
40 A QOB140HID 49.50 QOB240HID 108. ——
50 A QOB150HID 49.50 QOB250HID 108. ——
QOB-SWN—Switch Neutral—Common Trip—NEC 514.11
1-pole—2-Wire
2 Spaces —120 Vac
2-pole—3-Wire
3 Spaces—120/240 Vac
10 A — — QOB210SWN 116. QOB310SWN 170.
15 A — — QOB215SWN 116. QOB315SWN 170.
20 A — — QOB220SWN 116. QOB320SWN 170.
25 A — — QOB225SWN 116. QOB325SWN 170.
30 A — — QOB230SWN 116. QOB330SWN 170.
40 A — — QOB240SWN 116. QOB340SWN 170.
50 A — — QOB250SWN 116. QOB350SWN 170.
Table 9.23: QO/QOB Circuit Breaker Wire Sizes
Breaker Type Ampere Rating nWire Size (AWG)
Al Cu
QOB
1-pole
10–30 A #14–8 #14–8
10–30 A — two #14–10
35–70 A #8–2 #8–2
QOB
2-pole
10–30 A #14–8 #14–8
10–30 A — two #14–10
35–70 A #8–2 #8–2
80–125 A #4–2/0 #4–2/0
150–200 A #4–300 kcmil #4–300 kcmil
QOB
3-pole
10–30 A #14–8 #14–8
35–70 A #8–2 #8–2
80–125 A #4–2/0 #4–2/0
QOB-VH 110–150 A #4–300 kcmil #4–300 kcmil
QOB-GFI and
QOB-EPD
15–30 A #12–8 #14–8
40, 50, or 60 A #12–4 #14–6
n10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors.
35–60 A circuit breakers are suitable for use with 75 °C conductors.
Table 9.24: QO™ Arc-Fault Circuit Breakers op
Circuit Breaker Type Ampere
Rating q
1P 120 Vac
10 kAIR
1 Space Required
1P 120 Vac
22 kAIR
1 Space Required
Catalog Number $ Price Catalog Number $ Price
Combination
Arc-Fault
Interupter
15 A QOB115CAFI 306. QOB115VHCAFI 612.
20 A QOB120CAFI 306. QOB120VHCAFI 612.
Note: See Digest page 7-12 for accessories.
oUL Listed as HACR type for use with air conditioning, heating, and refrigeration equipment having
motor group combinations and marked for use with HACR type circuit breakers.
pQO arc-fault circuit breakers provide branch feeder protection (for example, QO115AFI) or
combination protection (for example, QO115CAFI) as required by the NEC and local code
adoption, and comply with UL 1699.
q10–30 A circuit breakers are suitable for use with 60 °C or 75 °C conductors. 35–60 A circuit
breakers are suitable for use with 75 °C conductors.
DE2A Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-11
NQ Factory Assembled
Panelboards
240 Vac, 48 Vdc
Class 1640 / Refer to Catalog 1640CT0801
Sub-feed Circuit Breakers
Main lugs or main circuit breaker interior—1Ø or 3Ø.
Maximum 1 circuit breaker per 225 A main lug or 250 A main
circuit breaker panelboard, 2 circuit breakers per 400–600 A
panelboard.
Table 9.25: Base Price (With Solid Neutral)
Mains
Rating
Main Lugs Main Circuit Breaker (Circuit Breaker Interrupt Rating—pages 6-2 through 6-8) a
Standard IC HIC Extra HIC I-Limiter™
$ Price Circuit
Breaker
Circuit
Breaker
$ Price Circuit
Breaker
$ Price Circuit
Breaker
$ Price
2-pole 3-pole 2-pole 3-pole 2-pole 3-pole 2-pole 3-pole 2-pole 3-pole
60 A — — QOB 1192. 1464. QOB-VH 1258. 1586. HJa2950. 3300. FI 4088. 4858.
100 A
720. 832. QOB 1254. 1562. QOB-VH 1382. 1712. HJa
2950. 3300. FI 4088. 4858.
720. 832. 2950. 3300. FI 4088. 4858.
720. 832. HD 2030. 2380. HG 2700. 3050. 2950. 3300. FI 4088. 4858.
150 Ac——HD 3180. 3530. HG 3840. 4190. HJa4000. 4350. ———
225 Ac772. 928.
QB
JD
QD
2450.
3980.
3084.
2800.
4300.
3434.
QG
JG
3740.
4510.
4090.
5100.
QJ
JJa
3970.
6450.
4320.
7280. KI 7436. 8680.
250 Ac——JD 4390. 4640. JG 5040. 6020. JJa7100. 8020. KI 8264. 9672.
400 Ac1422. 1634. LA 5366. 6106. LH 7708. 8834. LJ 10624. 10624. LR 13552. 13552.
600 Abc 2082. 2326. ——————LJ12930. 12930. LR 16002. 16002.
Note: Equipment Ground Bar—38.
aQL, HJ, HL, JJ, and JL circuit breakers are also available.
bCopper bus standard
cPrices are for 54-circuit and fewer interiors. See the Product Selector for 72- and 84-circuit interior pricing.
Table 9.26: Branch Circuit Breakers
Circuit Breaker
Ampere Rating
Plug-On or Bolt-On
$ Price
1-pole
120 Vac
2-pole
120/240 Vac
2-pole
240 Vac
3-pole
240 Vac
3-pole
208Y/120
Vac
Space Only
All Space Only
except below 28. 58. 58. 86. —
QOB–VH, Space
Only (125–150 A) —116. — 174. —
10,000 AIR—Branch Circuit Breakers—QO™, QOB, QO-H, QOB-H
15–60 A 68. 134. 260. d352. —
70 A 100. 208. 296. d396. —
80–100 A — 262. 380. d458. —
110–125 A — 482. ———
10,000 AIR—Combination Arc Fault Circuit Interrupters—QO-CAFI,
QOB-CAFI
15–20 A 470. —— ——
10,000 AIR—Qwik–Gard™—Class A—QO-GFI, QOB-GFI
Provided with a 5 mA setting on ground fault sensor
15–30 A 272. 488. — —920.
40–50 A — 488. — —920.
60 A — 488. — ——
10,000 AIR—Qwik–Gard—Class A—QO-EPD, QOB-EPD
Provided with a 30 mA setting on ground fault sensor
15–30 A 462. 828. — 1210. —
40–50 A — 828. — 1210. —
60 A — 828. — ——
10,000 AIR—Qwik–Gard—Class A—QO-EPE, QOB-EPE
Provided with a 100 mA setting on ground fault sensor
15–30 A — — — 1210. —
40–50 A — — — 1210.
(High Interrupting Capacity)
22,000 AIR Branch Circuit Breakers—QO-VH, QOB-VH
15–30 A 92. 212. — 462. —
35–60 A — 212. — 462. —
70 A — 292. — 556. —
80–100 A — 378. — 606. —
110–125 A — 1022. — 1746.e—
150 A — 1140. e——
22,000 AIR—Combination Arc Fault Circuit Interrupters—QO-VHCAFI,
QOB-VHCAFI
15–20 A 680. — — ——
22,000 AIR—Qwik-Gard—Class A—QO-VHGFI, QOB-VHGFI
15–30 A 575. — — ——
42,000 AIR Branch Circuit Breakers—QOH
35–60 A — 368. f———
70 A — 596. f———
80–100 A — 688. f———
110–125 A — 1402. f———
65,000 AIR Branch Circuit Breakers—QH, QHB
15–30 A 144. 348. — 596. —
Note: Shunt Trip, Auxiliary Switch, and Alarm Switch—accessories for circuit
breakers—add $ Price from page 7-12.
dUL Listed for use on 3Ø, grounded BØ systems, (5,000 AIR for this
application).
eBolt-on only; 2-pole requires 4 vertical spaces, 3-pole requires 6 vertical
spaces.
fPlug-on only.
Table 9.27: Specialty Branch Circuit Breakers
Circuit Breaker
Ampere Rating
Plug-On or Bolt-On
$ Price
1-pole
120 Vac
2-pole
120/240 Vac
2-pole
240 Vac
3-pole
240 Vac
Specialty Branch Circuit Breakers (10,000 AIR)
For High Intensity Discharge Lighting—QO-HID, QOB-HID
15–30 A 78. 148. —376.
40–50 A 78. 148. ——
Switch Neutral—QO-SWN, QOB-SWN
15–50 A —
1-pole
2-wire
(2 spaces)
—
2-pole
3-wire
(3 spaces)
—154. —220.
High Magnetic Trip (For applications subject to high initial inrush)—
QO-HM, QOB-HM
15–20 A 68. ———
Table 9.28: Sub-feed Circuit Breaker (110–225 A)
(SeeTable 9.29 for correct box size.)
No. of
Poles Ampacity QB QD QG HD HG JD JG
2 110–225 A 1218. 1762. 3812. 2456. 3500. 3020. 4220.
3 110–225 A 1848. 2296. 4608. 2872. 3798. 3370. 5100.
Space 110–225 A 826. 826. 826. 826. 826. 826. 826.
gQJ, HJ, HL, JJ, and JL circuit breakers are also available.
Table 9.29: Sub-feed Circuit Breaker Cabinet Data
Max. No. of
Branch Spaces
(Does not include
sub-feed
circuit breaker
spaces)
Box Height (20 in. W x 5.75 in. D)
225 A 250 A 400 A 600 A
Main
Lug
Main
Circuit
Breaker
Main
Lug
Main
Circuit
Breaker
Main
Lug
Main
Circuit
Breaker
30 50 62 74 86 74
Not
available
with MCB
42 56 68 74 86 80
54 56 68 80 — 80
72 62 74 86 — 86
84 68 80 — — —
hNot Available in Type 3R, 5, 12 if subfeed breaker is over 150 A.
PE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-12 © 2012 Schneider Electric
All Rights Reserved
NQ Factory Assembled
Panelboards
Common Features
Class 1640 / Refer to Catalog 1640CT0801
Sub-feed Lugs
NOTE: Available on main lug interiors only, 1Ø or 3Ø.
Feed-through Lugs
ó
Note: Neutral conductors must be of size and quantity per table above.
Note: Optional lugs are not available for Q frame main or QOB
circuit breakers
Table 9.30: Sub-feed Wire Range Per Phase
Mains
Rating Incoming Outgoing
Price
per
Panel
100 one #6-2/0 Al or Cu one #6-2/0 Al or Cu $128.
225 one 1/0-350 kcmil Al or Cu one 1/0-350 kcmil Al or Cu $128.
400 one 1/0-750 kcmil Cu only one 1/0-750 kcmil Cu only $164.
Table 9.31: Sub-feed Lug Cabinet Data
Max. No. of
Branch Spaces
Box Height (20 in. W x 5.75 in. D)
100 A 225 A 400 A
18 MH26 — —
30 MH32 MH38 MH50
42 — MH44 MH50
54 — MH44 MH50
72 — MH50 MH62
84 — MH56 MH68
Table 9.32: Feed-through Lugs
Mains
Rating Feed-Through Wire Range Per Phase $ Price
100 A one #6-2/0 Al or Cu 344.
225 A one #6–350 kcmil Al or Cu 344.
400 A one 1/0–750 kcmil or two 1/0–350 kcmil Al or Cu 826.
600 A two 1/0–750 kcmil Al or Cu 826.
Table 9.33: Feed-through Lug Cabinet Data
Max. No.
of Branch
Spaces
Box Height (20 in. W x 5.75 in. D)
225 A 250 A 400 A 600 A
Main Lugs
Main
Circuit
Breaker
Main Lugs
Main
Circuit
Breaker
Main Lugs
Main
Circuit
Breaker a
30 38 50 50 62 62 68
42 38 50 56 68 62 80
72 50 62 68 80 74 —
84 56 68 68 80 80 —
a8.75 in. deep box, ship fully assembled only.
Table 9.34: Ground Bars
Ground Bars $ Price Adder
Equipment Ground Bar 38.
Copper Ground Bar (add to Equipment Ground Bar price) 52.
Insulated/Isolated Ground Bar
(add to Equipment Ground Bar price) 86.
Table 9.35: Name Plates
Name Plates $ Price
Adder
Standard white face/black letter laminated bakelite,
1 in. x 3.5 in., adhesive backed or screw mountable with
screws in a bag assembly (price includes engraving)
78.
Table 9.36: Copper Bus Bars
Copper Bus Bars $ Price
Adder
100 A, 225 A, 250 A 128.
400 A 388.
600 A Standard
Table 9.37: Copper Neutrals
Copper Neutrals $ Price
Adder
100–600 A 132.
Table 9.38: 200% Rated Neutrals
Panelboards with 200% rated neutrals are not available
with 250 A J- and K-frame main circuit breakers or
integral lighting contactors
Add Per Panel
$ Price
100 Aaone #6-2/0 kcmil Al or Cu per lug 586.
225 Aaone #6-350 kcmil Al or Cu per lug 763.
400 Aaone #1/0-750 kcmil Al or Cu per lug or
two 1/0-300 kcmil per lug 950.
aTwo incoming neutral lugs per panel
Table 9.39: NQ Main Neutral Conductors—Required Size
and Quantity
Panelboard
Ampacity Neutral Conductors Required Actual Lug Wire
Range
100/125 (2) 1/0 Cu or Al (2) #4-300kcmil
225 (2) 4/0 Cu or (2) 300 kcmil Al (2) #4-300 kcmil
400 A
(4) 3/0 Cu or
(4) 250 kcmil Al
(2) 600 kcmil Cu
(2) 750 kcmil Al
(2) 1/0-300 kcmil or
(1) 750 kcmil
Table 9.40: Metal Directory Frames
Metal Directory Frame $ Price Adder
Replaces standard plastic stick-on directory pouch 140.
Table 9.41: Hinged Door-in-Door Trims
Hinged Door-in-Door Trim Add Per Panel
$ Price
Hinged Door-in-Door Trim has piano hinge down one side.
Inner door has a lock, outer door is retained with screws 646.
Hinged Door-in-Door with Outer Door Lock in place of screws 836.
Table 9.42: Weatherproof or Dusttight Cabinets—Type 3R, 5, 12
Weatherproof or Dusttight Cabinets $ Price Adder
Note: 600 A L-Frame main circuit breaker NQ panelboards are
not available with a weatherproof enclosure (Use I-Line)
400 and 600 A NQ panelboards with sub-feed circuit breakers are
not available with a weatherproof enclosure (Use I-Line).
400 A NQ panelboards are available with a subfeed breaker up to
150 A. See Table 9.29 on page 9-11.
1516.
Table 9.43: Optional Factory Assembled Lugs
for Main Lug Interiors
Main Lug Interiors: Price Per Pole Adder
100A 225A 400A 600A
Aluminum Compression Lugs 58. 58. 148. 148.
Copper Mechanical Lugs 70.108.148.168.
Copper Compression Lugs 70.108.148.168.
Table 9.44: Optional Factory Assembled Lugs
for Main Circuit Breaker Interiors
Main Circuit Breaker Interiors: Price Per Pole Adder
H Frame J Frame LA Frame LC Frame
Aluminum Compression Lugs 58. 98. 148. 148.
Copper Mechanical Lugs 70. 108. 148. 168.
Copper Compression Lugs 70. 108. 148. 168.
Table 9.45: Surgelogic™ SurgeLoc Plug-On SPD b
Surge Current
Rating kA
Vol tage
120 / 240 V 208 Y / 120 V 240 / 120 HLD
80 kA 6170. 6540. 6540.
100 kA 6540. 7370. 7370.
120 kA 7370. 7870. 7870.
160 kA 8430. 8620. 8620.
200 kA 9720. 9770. 9770.
240 kA 10840. 12370. 12370.
bSurgeLogic units occupy 12 circuit positions (6 adjacent mounting
spaces per side.)
Table 9.46: Surgelogic SPD Options
Description $ Price
Surge Counter Standard
Dry Contacts Standard
Remote Monitor 2588.
Note: Additional factory modifications, See Digest page 9-38.
PE1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 9-13
9PANELBOARDS
NF Merchandised
Panelboards
20-inch Wide Enclosures 480Y/277 Vac Max.
Class 1670 / Refer to Catalog 1670CT0701
Table 9.47: NF Main Lug Interiors—Use I-Line™ Panelboards on 480 V 3Ø3W Delta Applications
Max No. of
Single Pole
EDB Circuit
Breakers
Mains
Rating
$ Total Price a Interior Only b
NEMA 1 Enclosure NEMA 3R, 5, 12 Enclosure f
Box
20 in. W x 5.75 in. D dMono-Flat™ Front eHinged Front Enclosure
20 in. W x 6.5 in. D Height (In.)
NEMA 1 NEMA
3R, 5, 12 Catalog No. c$ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price
(Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire
18 125 2056. 3638. NF418L1 1446. MH26 113. NC26( ) 497. NC26( )HR 620. MH26WP 2192. 26
2448. 4030. NF418L1C 1838. MH26 NC26( ) NC26( )HR MH26WP
30 125 2406. 3970. NF430L1 1766. MH32 113. NC32( ) 527. NC32( )HR 657. MH32WP 2204. 32
2802. 4366. NF430L1C 2162. MH32 NC32( ) NC32( )HR MH32WP
30 250 2881. 4435. NF430L2 2219. MH38 113. NC38( ) 549. NC38( )HR 687. MH38WP 2216. 38
3286. 4840. NF430L2C 2624. MH38 NC38( ) NC38( )HR MH38WP
42 250 3194. 5021. NF442L2 2418. MH44 113. NC44( ) 663. NC44( )HR 830. MH44WP 2603. 44
3602. 5429. NF442L2C 2826. MH44 NC44( ) NC44( )HR MH44WP
54 250 4370. 6067. NF454L2 2616. MH50 113. NC50( ) 729. NC50( )HR 912. MH50WP 2609. 56
4775. 6472. NF454L2C 3021. MH50 NC50( ) NC50( )HR MH50WP
66g250 4800. 6485. NF466L2 3800. MH62 113. NC62( ) 887. NC62( )HR 887. MH62WP 2685. 62
5442. 7127. NF466L2C 4442. MH62 NC62( ) NC62( )HR MH62WP
30 400 3308. 5075. NF430L4 2466. MH50 113. NC50V( ) 729. NC50V( )HR 912. MH50WP 2609. 50
3716. 5483. NF430L4C 2874. MH50 NC50V( ) NC50V( )HR MH50WP
42 400 3572. 5325. NF442L4 2673. MH56 113. NC56V( ) 786. NC56V( )HR 983. MH56WP 2652. 56
3895. 5648. NF442L4C 2996. MH56 NC56V( ) NC56V( )HR MH56WP
66g400 5285. 6957. NF466L4 4200. MH74 113. NC74V( ) 972. NC74V( )HR 1215. MH74WP 2757. 74
5792. 7464. NF466L4C 4707. MH74 NC74V( ) NC74V( )HR MH74WP
84g400 6524. 8261. NF484L4 5346. MH86 113. NC86V( ) 1065. NC86V( )HR 1430. MH86WP 2915. 86
7169. 8906. NF484L4C 5991. MH86 NC86V( ) NC86V( )HR MH86WP
30 600 3838. —NF430L6C 2996. MH50 113. NC50V( ) 729. NC50V( )HR 912. Factory
Assembled
Only
50
42 600 4087. —NF442L6C 3188. MH56 113. NC56V( ) 786. NC56V( )HR 983. 56
66g600 6094. —NF466L6C 5009. MH74 113. NC74V( ) 972. NC74V( )HR 1215. 74
84g600 7553. —NF484L6C 6375. MH86 113. NC86V( ) 1065. NC86V( )HR 1430. ———
800 Factory Assembled Only
Table 9.48: NF Main Circuit Breaker Interiors—Use I-Line Panelboards on 480 V 3Ø3W Delta Applications
Max. No. of
One-pole
EDB
Circuit
Breakers
Mains
Rating
$ Total Price aMain Circuit
Breaker Adapter Kit Main
Circuit
Breaker
Frame
Interior Only b
NEMA 1 Enclosure NEMA 3R, 5, 12 Enclosure f
Box
20 in. W x 5.75in. D d
Mono-Flat™
Front eHinged Front Enclosure
20 in. W x 6.5 in. D Height
(In.)
NEMA 1 NEMA
3R,5,12 Kit $ Price Catalog No. c$ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price
(Single Phase 3-Wire: Factory Assembled Only) Three Phase 4-Wire
15 125 2056. 3638. Back-fed
Main
Breakerh
—EDB, EGB
or EJB
NF418L1 1446. MH26 113. NC26( ) 497. NC26( )HR 620. MH26WP 2192. 26
2448. 4030. NF418L1C 1838. MH26 NC26( ) NC26( )HR MH26WP
27 125 2406. 3970. —NF430L1 1766. MH32 113. NC32( ) 527. NC32( )HR 657. MH32WP 2204. 32
2802. 4366. NF430L1C 2162. MH32 NC32( ) NC32( )HR MH32WP
18 125 2888. 4442. N150MH
or
N100MFIi
780.
HD/HG/
HJ/HL
or FI
NF418L1 1446. MH38 113. NC38( ) 549. NC38( )HR 687. MH38WP 2216. 38
3280. 4834. NF418L1C 1838. MH38 NC38( ) NC38( )HR MH38WP
30 125 3322. 5149. NF430L1 1766. MH44 113. NC44( ) 663. NC44( )HR 830. MH44WP 2603. 44
3718. 5545. NF430L1C 2162. MH44 NC44( ) NC44( )HR MH44WP
30 250 3841. 5608.
N250MJ
or
N250MKCi
780.
JD/JG/
JJ/JL
or KI
NF430L2 2219. MH50 113. NC50( ) 729. NC50( )HR 912. MH50WP 2609. 50
4246. 6013. NF430L2C 2624. MH50 NC50( ) NC50( )HR MH50WP
42 250 4097. 5850. 780. NF442L2 2418. MH56 113. NC56( ) 786. NC56( )HR 983. MH56WP 2652. 56
4505. 6258. NF442L2C 2826. MH56 NC56( ) NC56( )HR MH56WP
54 250 5278. 6947. 780. NF454L2 2616. MH62 113. NC62( ) 786. NC62( )HR 983. MH62WP 2652. 56
5683. 7352. NF454L2C 3021. MH62 NC62( ) NC62( )HR MH62WP
66g250 5665. 7337. 780. NF466L2 3800. MH74 113. NC74( ) 972. NC74( )HR 1215. MH74WP 2757. 74
6307. 7979. NF466L2C 4442. MH74 NC74( ) NC74( )HR MH74WP
30 400 4246. 5931. N400Mi780.
LA/LH
NF430L4 2466. MH62 113. NC62V( ) 887. NC62V( )HR 1109. MH62WP 2685. 62
4654. 6339. NF430L4C 2874. MH62 NC62V( ) NC62V( )HR MH62WP
42 400 4514. 6195. N400Mi780. NF442L4 2673. MH68 113. NC68V( ) 948. NC68V( )HR 1185. MH68WP 2742. 68
4837. 6518. NF442L4C 2996. MH68 NC68V( ) NC68V( )HR MH68WP
66g400 6158. 7895. N400Mi780. NF466L4 4200. MH86 113. NC86V( ) 1065. NC86V( )HR 1430. MH86WP 2915. 86
6665. 8402. NF466L4C 4707. MH86 NC86V( ) NC86V( )HR MH86WP
aTotal Price includes: interior, front, main circuit breaker adapter kit, and enclosure.
bOrder branch circuit breakers separately.
c“C” suffix indicates copper bussing.
dEmbossed mounting holes add a 0.25-inch standoff to back of MH box.
eAdd “F” for flush mount, “S” for surface mount.
fEnclosure includes trim kit.
gUse only if the Local Jurisdiction where this panelboard interior is being applied has adopted the 2008 NEC, which allows single panelboard interiors greater than 42 circuits.
hBack-fed EDB 125 A 3 pole main circuit breaker must be ordered separately and field installed. Maximum breaker rating opposite is 20A.
iSelect the appropriate main circuit breaker from pages starting on 7-21 and add the circuit breaker Price to the total Price of the panelboard.
Table 9.49: NF Merchandised SPD Box Selection Table
Mains
Rating
Max.
Breaker
Spaces
Main Lug Panelboard Box Requirements Main Circuit Breaker Panelboard Box Requirements
NEMA 1
Enclosure NEMA 3R, 5, 12 Enclosure NEMA 1 Enclosure NEMA 3R, 5, 12
Enclosure
Box $ Price Front $ Price Hinged $ Price Enclosure $ Price Box $ Price Front $ Price Hinged $ Price Enclosure $ Price
250A 42 MH56 113. NC56( ) 887. NC56( )HR 1109. MH56WP 2685. MH68 113. NC68( ) 972. NC68( )HR 1215. MH68WP 2742.
400 A 42 MH68 NC68V( ) 972. NC68V( )HR 1215. MH68WP 2757. MH80 NC80( ) 1722. M/B NC80V( )HR 1430. MH80WP 2915.
PE1A Discount
Schedule
www.schneider-electric.us
9-14 © 2012 Schneider Electric
All Rights Reserved
9PANELBOARDS
NF Merchandised
Panelboards
Accessories
Class 1670 / Refer to Catalog 1670CT0701
Table 9.50: NF Merchandised Neutrals
Mains
Ampacity
200% Neutral Kit Copper 100% Neutral Kit
Catalog No. $ Price Box Add Schedule Catalog No. $ Price Box Add Schedule
125 NFNL1 1029. No Adder PE-1A NFN1CU 405. No Adder PE-1A
250 NFNL2 1277. NFN2CU
400 NFNL4a1914. No Adder PE-1A NFN6CU 1148. No Adder PE-1A
600 Factory Assembled Only NFN6CUa
aNot to be used with SFL, FTL, or SFB. These combinations are factory assembled only.
Table 9.51: Modifications (Single- or Three-phase)
Mains
Ampacity
Sub-feed Lugs bc Feed-through Lugs bc
Mains
Ampacity
Sub-feed Circuit Breaker Kits b
(circuit breaker not Included) d
Schedule
Catalog No. $ Price Schedule Catalog No. $ Price Schedule
Single Sub-feed
Circuit Breaker
Twin Sub-feed
Circuit Breakers
Catalog No. $ Price Schedule Catalog No. $ Price
125 NF125SFL 167. PE-1A NF125FTL 336. PE-1A 250 NF250SFBH/NF250SFBJ 1029. PE-1A — ——
250 NF250SFL 213. PE-1A NF250FTL 476. PE-1A 400 ———NF600SFBH 1290. PE1A
400 NF400SFLe356. PE-1A NF400FTL 507. PE-1A ———NF600SFBJ
600 f—— f—— 600 FACTORY ASSEMBLED ONLY
800 — ———
800 FACTORY ASSEMBLED ONLY
Note: NF250SFBH and NF600SFBH are for use with HDL, HGL, HJL, and HLL circuit breakers. NF600SFBJ are for use with JDL, JGL, JJL, and JLL circuit breakers.
bAvailable factory assembled only on non-linear panelboards.
cSelect box from the Box Selection Table.
dOrder appropriate circuit breaker.
eUse copper wire only.
fAvailable factory assembled only.
Table 9.52: Special Features Box Selection Table—Standard Mechanical Lugs Only
Main Lugs Only
Feature Sub-feed Lugs Feed-through Lugs Sub-feed Circuit Breaker
No. of Circuits 18 30 42 66 84 18 30 42 66 84 30 42 66
Ampacity Cat. No. Cat. No. Cat. No. Cat No. Cat No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
100/125MH26MH32———MH32MH38——————
250 — MH38 MH44 MH62 — — MH50 MH56 MH74 — MH56 MH62 MH80
400 — MH50 MH56 MH74 MH86 — MH56 MH62 MH80 MH92 MH68 MH74 —
600 —gggg—ggggggg
800
gAvailable factory assembled only.
Table 9.53: Special Features Box Selection Table—Standard Mechanical Lugs Only (continued)
Vertical Main Circuit Breaker hBack-fed Main Circuit Breaker
Feature Feed-through Lugs Sub-feed Circuit Breaker Feed-through Lugs
No. of Circuits 18 30 42 66 30 42 18 30
Ampacity Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
100/125 MH44 MH50 — — — — MH32 MH38
250 — MH62 MH68 MH86 MH68 MH74 MH38 MH44
400h— MH68 MH74 MH92 MH80 MH86 — —
600 Available factory assembled only. — —
h400 A dimension for LA/LH main circuit breakers only.
Table 9.54: Optional Main Lug Kits for Main Lug Panelboards
Ampacity AL Compression Lug Kit CU Mechanical Lug Kit CU Compression Lug Kit i
Catalog No. Lug Wire Range $ Price Schedule Catalog No. Lug Wire Range $ Price Schedule Catalog No. Lug Wire Range $ Price Schedule
125 NFALV1 jone #4–300 kcmil 177. PE-1A NFCUM1 #6–2/0 AWG 347. PE-1A NFCUV1 kone #6–1/0 345. PE-1A
250 NFALV2 one 250–350 kcmil 333. NFCUM2 #6–250 kcmil NFCUV2 kone 2/0–300 kcmil 417.
400 NFALV4 two 2/0–500 kcmil 1122. PE-1A NFCUM4 one 1/0–750 kcmil,
two 1/0–350 kcmil 987. PE-1A NFCUV4 one 400–750 kcmil 767. PE-1A
600 NFALV6 two 2/0–500 kcmil 1206. PE-1A NFCUM6 two 1/0–750 kcmil 2236. PE-1A NFCUV6 two 250–500 kcmil 1364. PE-1A
800 Contact your local Schneider Electric representative or distributor
iUse copper wire only.
jUse of this kit requires an additional 6 in. added to box height.
kUse of this kit to terminate larger than standard wire size requires an additional 6 in. added to box height.
Table 9.55: NF Accessories
Description Catalog No. $ Price Schedule Description Catalog No. $ Price Schedule
Aluminum Equipment Ground Bar PK27GTA 33.80 DE-3A Filler plate (15 per package) NFFP15 113.00lPE-1A
Copper Equipment Ground Bar PK27GTACU 84.00 PE-1A EXB Fixed padlock attachment, Lock ON/OFF
for ED, EG, and EJ Circuit Breakers 1, 2, or 3 poles EDPA 26.00 DE-2
Large Aluminum Lug for Equipment Ground Bar PK23GTAL 40.70 DE-3A
Equipment Ground Bar Insulator Kit PKGTAB 43.80 EXB Fixed padlock attachment, Lock OFF only
for ED, EG, and EJ Circuit Breakers 1, 2, or 3 poles EDPAF 30.00 DE-2
Circuit I.D. number strips
1–102 odd/even (left side numbered 1, 3, 5...101) NF102OE
7.90 PE-1A
103–204 odd/even (left side numbered 103, 105, 107...203) NF204OE Oversized Lugs for Neutral or Ground Bar
1–102 sequential (left side numbered 1, 2, 3 ...102) NF102S #10 to #2 Al or #14 to #4 Cu QO70AN 9.90
DE-3A
103–204 sequential (left side numbered 103, 104, 105... 204) NF204S #4 to #1/0 Al or Cu Q1100AN 11.10
Rail and Deadfront Extensions #1 to #4/0 Al or Cu Q1150AN 32.40
6 in. Extension NF6RDE 252.00
PE-1A
Drip Hood for 20 in. wide enclosures MHT2DH20 315.00 PE-1A
12 in. Extension NF12RDE 284.00
18 in. Extension NF18RDE 344.00
lFiller plates are $7.50 each and must be ordered in packages of 15.
PE1A DE3A DE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-15
Circuit Breakers For NF Merchandised Panelboards
Class 515
E-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
Table 9.56: E-frame—125 A, Thermal-magnetic (480Y/277 Vac)
Ampere
Rating
ED, EG, EJ
(480Y/277 Vac)
“D” Interrupting Level
18 kA @ 480Y/277 Vac
“G” Interrupting Level
35 kA @ 480Y/277 Vac
“J” Interrupting Level
65 kA @ 480Y/277 Vac Terminal
Wire Range
Hold Trip Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price
1-pole, 277 Vac
15 A
270 875
EDB14015ab
150.
EGB14015ab
255.
EJB14015ab
408.
AL30FD
#14–#6
Al or Cu
20 A EDB14020ab EGB14020ab EJB14020ab
25 A EDB14025bEGB14025bEJB14025b
30 A EDB14030bEGB14030bEJB14030b
35 A
630 1800
EDB14035b
150.
EGB14035b
225.
EJB14035b
408. AL100FD
#14–2/0
Al or Cu
40 A EDB14040bEGB14040bEJB14040b
45 A EDB14045bEGB14045bEJB14045b
50 A EDB14050bEGB14050bEJB14050b
60 A EDB14060 EGB14060 EJB14060
70 A EDB14070 302. EGB14070 507. EJB14070 812.
2-pole, 480Y/277 Vac c
15 A
270 875
EDB24015b
536.
EGB24015b
776.
EJB24015b
1241.
AL30FD
#14–#6
Al or Cu
20 A EDB24020bEGB24020bEJB24020b
25 A EDB24025bEGB24025bEJB24025b
30 A EDB24030bEGB24030bEJB24030b
35 A
630 1800
EDB24035b
536.
EGB24035b
776.
EJB24035b
1241. AL100FD
#14–2/0
Al or Cu
40 A EDB24040bEGB24040bEJB24040b
45 A EDB24045bEGB24045bEJB24045b
50 A EDB24050bEGB24050bEJB24050b
60 A EDB24060 EGB24060 EJB24060
70 A EDB24070 756. EGB24070 1280. EJB24070 2048.
80 A
1000 2300
EDB24080
756.
EGB24080
1280.
EJB24080
2135. AL100FD
#14–2/0
Al or Cu
90 A EDB24090 EGB24090 EJB24090
100 A EDB24100 EGB24100 EJB24100
110 A EDB24110 1946. EGB24110 2586. EJB24110 3879.
125 A EDB24125 EGB24125 EJB24125
3-pole, 480Y/277 Vac
15 A
270 875
EDB34015b
669.
EGB34015b
1131.
EJB34015b
1358.
AL30FD
#14–#6
Al or Cu
20 A EDB34020bEGB34020bEJB34020b
25 A EDB34025bEGB34025bEJB34025b
30 A EDB34030bEGB34030bEJB34030b
35 A
630 1800
EDB34035b
669.
EGB34035b
1131.
EJB34035b
1358. AL100FD
#14–2/0
Al or Cu
40 A EDB34040bEGB34040bEJB34040b
45 A EDB34045bEGB34045bEJB34045b
50 A EDB34050bEGB34050bEJB34050b
60 A EDB34060 EGB34060 EJB34060
70 A EDB34070 911. EGB34070 1292. EJB34070 2562.
80 A
1000 2300
EDB34080
911.
EGB34080
1292.
EJB34080
2562. AL100FD
#14–2/0
Al or Cu
90 A EDB34090 EGB34090 EJB34090
100 A EDB34100 EGB34100 EJB34100
110 A EDB34110 2421. EGB34110 3216. EJB34110 4826.
125 A EDB34125 EGB34125 EJB34125
EPDs (Equipment Protection Devices), 1-pole, 277 Vac, Thermal-magnetic with 30 mA ground-fault protectiond
15 A
270 875
EDB14015EPDab
1151.
EGB14015EPDab
1256.
EJB14015EPDab
1409. #14–#6 Cu
or
#12–#4 Al
20 A EDB14020EPDab EGB14020EPDab EJB14020EPDab
30 A EDB14030EPDbEGB14030EPDbEJB14030EPDb
40 A 630 1800 EDB14040EPDb1151. EGB14040EPDb1256. EJB14040EPDb1409.
50 A EDB14050EPDbEGB14050EPDbEJB14050EPDb
Note: All EDB, EGB, and EJB circuit breakers are UL Listed as HACR Type. For 50 oC calibration, use a CA suffix. NF branch circuit breakers are fungus proof as standard.
aUL Listed as SWD (Switching duty rated).
bUL Listed as HID (High Intensity Discharge rated).
cUL Listed for use on 240 V Corner-grounded Delta Systems (Grounded B Phase). See data bulletin 2700DB0202.
dAll EPDs occupy two spaces, with or without Alarm Switch option. For alarm switch, add 158 list Price and the suffix BA.
EDB, EGB, EJB
1-pole
15–70 A
EDB, EGB, EJB
2-pole
15–125 A
EDB, EGB, EJB
3-pole
15–125 A
EDB-EPD
1-pole
with Alarm Switch
Table 9.57: Factory installed Electrical Accessories
Auxiliary Switch (1A/1B) Alarm Switch (NO) Coil Burden Max. (VA) Minimum Recommended
Supply Transformer (VA)
288 50
Monitors circuit breaker contact status and provides
a remote signal indicating the circuit breaker
contacts are OPEN or CLOSED.
Application
Max Load = 10 A @ 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire
Used with control circuits and is actuated
only when the circuit breaker has tripped.
Application
Max Load = 7 A @ 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire.
Shunt Trip—Trips the circuit breaker from a remote location by means
of a coil energized from a separate circuit. A 120 V shunt trip will
operate at 55% or more of rated voltage.
Application
For use with momentary or maintained push button. 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire.
Table 9.58: Factory Installed Electrical Accessory Packages for
ED, EG, EJ Circuit Breakers
Accessory Package Suffix $ Price
Auxiliary Switch/Alarm Switch Packageef AABA 312.
Shunt Trip Packageef SA 755.
Auxiliary Switch/Alarm
Switch/Shunt Trip Packageef AABASA 1067.
Alarm Switch (N.O.) Package for EPDs only BA 237.
eAccessory package takes an additional pole space.
fNot available for EPD.
Table 9.59: Terminal Nut Insert Kit
Circuit Breaker Type Qty. per Kit Catalog No. $ Price
ED, EG, EJ 3 TIKFD 17.40
Table 9.60: Handle Accessories
Circuit Breaker Type No. of Poles Catalog No. $ Price
EXB Fixed Padlock Attachment, Lock ON/OFF
ED, EG, EJ 1, 2, or 3 EDPA 39.00
EXB Fixed padlock attachment, Lock OFF only
ED, EG, EJ 1, 2, or 3 EDPAF 45.00
EXB Removable padlock attachment, Lock OFF only
ED, EG, EJ 1, 2, or 3 HPAFD 25.50
EXB Handle Ties
ED, EG, EJ Ties 2 – 1P ECB2HT 16.80
Ties 3 – 1P ECB3HT 17.85
Table 9.61: Interrupt Ratings (kA)
EDB EGB EJB
120 V 25 65 100
240 V 18 (1P), 25 35 (1P), 65 65 (1P), 100
480Y/277 V 18 35 65
Table 9.62: Mechanical Lug Kit Information (Al lugs for use with Al or Cu wire)
Circuit Breaker Application Number of Wires Per Lug
and Wire Range Catalog Number Lugs
Per Kit
$ price
Per Kit
Standard Ampere Rating Optional Ampere Rating
EDB, EGB, EJB
15–30 A — — one #12—#6 AWG Al or
one #14—#6 AWG Cu AL30FD 3
41.30
35–125 A EDB, EGB, EJB 15–30 A gone #12—2/0 AWG Al or
one #14—2/0 AWG Cu AL100FD 3
— — EDB, EGB, EJB 15–125 A one #14—1/0 AWG Cu CU100FD 3
gFactory installed only. Use suffix “LH”
DE2 Discount
Schedule
9-16 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
9PANELBOARDS
NF Factory Assembled
Panelboards a
Maximum 480Y/277 Vac
Class 1670 / Refer to Catalog 1670CT0701
Factory Assembled Pricing
aUse I-Line™ Panelboards on 480 V 3Ø3W Delta applications.
Sub-feed Circuit Breaker
Available on 1Ø or 3Ø, 250–800 A main lugs or 250–600 A main circuit breaker interiors
•One sub-feed HD, HG, HJ, or HL or JD, JG, JJ, or JL circuit breaker per 250 A panelboard
•Two sub-feed HD, HG, HJ, or HL or two JD, JG, JJ, or JL circuit breakers per 400 A panelboard (do not mix H and J in a Panel)
•One sub-feed LA, LH, or LC circuit breaker (400 A max.) and one JD, JG, JJ, or JL circuit breaker or two sub-feed JD, JG,
JJ, or JL circuit breakers per 600 A or 800 A panelboard (JJ and LC sub-feed circuit breakers cannot be used together).
Table 9.63: Base $ Price (including solid neutral)
Mains
Rating
Main Lugs Main Circuit Breaker (Circuit Breaker Interrupt Rating—7-2 through 7-8) ab
Standard IC HIC Extra HIC I-Limiter™
2-pole 3-pole Circuit
Breaker 2-pole 3-pole Circuit
Breaker 2-pole 3-pole Circuit
Breaker 2-pole 3-pole Circuit
Breaker 2-pole 3-pole
100 A — — ED c1636. 1882. EG c2100. 2416. ——————
100 A————————HJ3248. 3598. FI 4250. 4884.
125 A 846. 972. ED c3372. 3762. EGc4324. 4976. ——————
150 A — — HD 3270. 3620. HG 4048. 4398. HJ 4070. 4420. ———
225 A d——JD4120. 4380. JG 5070. 5400. JJ 6620. 7330. KI 7266. 8352.
250 A d1002 1152. JD 4500. 5140. JG 6180. 6180. JJ 7190. 8450. KI 9154. 10522.
400 A d1326. 1524. LA 5330. 6126. LH 7712. 8864. LC 8506. 9776. LI 9350. 10746.
600 A de 2366. 2622. ——————LC9554. 10884. LI 13640. 15678.
800 Ae3550. 3900. ————————————
aHL and JL frame circuit breakers are also available as main circuit breakers.
bContact your local Schneider Electric representative or distributor for Micrologic™ trip main circuit breaker pricing.
cBack-fed main circuit breaker.
dPrices are for 54-circuit and fewer interiors. See the Product Selector for 66- and 84-circuit interior pricing.
eCopper bus only.
Table 9.64: Branch Circuit Breakers—$ Price per circuit breaker
Circuit Breaker
Ampere Rating
Standard Interrupting
25,000 AIR @ 240 Vac,
18,000 AIR @ 480Y/277 Vac
ED Bolt-on Branch
High Interrupting
65,000 AIR @ 240 Vac,
35,000 AIR @ 480Y/277 Vac
EG Bolt-on Branch
Extra High Interrupting
100,000 AIR @ 240 Vac,
65,000 AIR @ 480Y/277 Vac
EJ Bolt-on Branch
1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price
15–60 A 192. 442. 748. 324. 746. 1264. 518. 1196. 2024.
70 A 342. 872. 1046. 578. 1474. 1710. 924. 2120. 2540.
80–100 A — 872. 1046. —1474. 1710. —2120. 2540.
110–125 A — 2210. 2724. —4114. 4754. —5300. 6300.
Space Only 42. 84. 126. 42. 84. 126. 42. 84. 126.
Note: All ED, EG, and EJ branch circuit breakers are UL Listed as HACR type.
Table 9.65: EDB-EPD Equipment Protection Device Branch Circuit Breakers fg
Circuit Breaker
Ampere Rating
Standard Interrupting
25,000 AIR @ 240 Vac,
18,000 AIR @ 480Y/277 Vac
ED Bolt-on Branch
High Interrupting
65,000 AIR @ 240 Vac,
35,000 AIR @ 480Y/277 Vac
EG Bolt-on Branch
Extra High Interrupting
100,000 AIR @ 240 Vac,
65,000 AIR @ 480Y/277 Vac
EJ Bolt-on Branch
1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price 1-pole $ Price 2-pole $ Price 3-pole $ Price
15–60 A 1472. —— 1596. —— 1788. ——
fAll 1-pole EDB-EPD branches use 2 poles of mounting space.
gFor bell alarm in EDB-EPD branch breaker, add 158. to branch breaker price.
Table 9.66: Sub-feed Circuit Breaker (150–400 A)
No. of
Poles HD HG JD JG LA LH LC hSpace
22456. 3500. 3020. 4220. 3980. 5534. 8634. 826.
32872. 3798. 3370. 5100. 4916. 6510. 10156. 826.
hJJ and LC sub-feed circuit breakers cannot be used together.
Table 9.67: Sub-feed Circuit Breaker Cabinet Data
Max. No. of Branch Spaces
(Does not include sub-feed
circuit breaker spaces)
Box Height (20 in. W x 5.75 in. D)
250 A 400 A LA/LH 600 A 800 A
Main Lugs Main Breaker Main Lugs Main Breaker Main Lugs Main Breaker iMain Lugs j
30 56 68 68 80 74 80k68
42 62 74 74 86 80 86k74
54 68 80 80 92 86 92k80
66 80 N/A
84 N/A
i600 A main circuit breaker panelboards require an 8.75 in. deep, 26 in. wide box.
j800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box.
kDimensions also for 400 A LC/LI main circuit breaker panels.
PE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-17
NF Factory Assembled
Panelboards
Common Features
Class 1670 / Refer to Catalog 1670CT0701
Note: Neutral conductors must be of size and quantity per table above.
NOTE: For additional factory modifications, See Digest page 9-38.
Table 9.68: Sub-feed (Double) Lugs (Standard Aluminum Mechanical Lugs)
An additional mains end termination point that can be used to feed out to
another panelboard or device from the incoming service lines.
NOTE: Available on main lug interiors only.
Mains Rating Sub-feed Wire Range
Wire Bending Space per NEC Table 373-6 $ Price
125 A two #6–2/0 Al or Cu 128.
250 A two 1/0–350 kcmil Al or Cu 128.
400 A two 1/0–600 kcmil Cu 344.
600 A (4) 4/0–500 kcmil Al or Cu 344.
800 A (6) 3/0–500 kcmil Al or Cu 522.
Table 9.69: Sub-feed Lug Cabinet Data (Standard Aluminum Mechanical Lugs)
Max. No. of
Branch Spaces
Main Lugs Box Height in Inches (20 in. W x 5.75 in. D)
125 A 250 A 400 A 600 A 800 A a
18 26 — — — —
30 32 38 50 74 74
42 —44568080
54 —50628686
a800 A main lug panelboards require an 8.75 in. deep and 26 in. wide box.
Table 9.70: Feed-through Lugs (Standard Aluminum Mechanical Lugs)
A second set of lugs assembled at the opposite end from the mains of the
panelboard. Often used to connect another panelboard or device to the
incoming lines. Available on main lugs and main circuit breaker panelboards.
Mains Rating Feed-through Wire Range Wire Bending Space per NEC
Table 373-6 $ Price
125 A one #6–2/0 kcmil Al or Cu 344.
250 A one #6–350 kcmil Al or Cu 344.
400 A one 1/0–750 kcmil or
two 1/0–350 kcmil Al or Cu 826.
600 A two 1/0–600 kcmil Al or Cu 826.
Table 9.71: Feed-through Lug Cabinet Data (Standard Aluminum
Mechanical Lugs)
Max. No. of
Branch Spaces
Box Height in Inches (20 in. W x 5.75 in. D)
125 A 100/125 A 250 A 400 A LA/LH 600 A 800 A
Main
Breaker
(back-fed
only)
Main
Lugs
Main
Breaker
Main
Lugs
Main
Breaker
Main
Lugs
Main
Breaker
Main
Lugs
Main
Breaker
b
Main
Lugs
c
18 38 32 44 — — — — — — —
30 44 38 50 50 62 56 68 62 74 56
42 50 — — 56 68 62 74 68 80 62
54 — ——62746880 74 86 68
b600 A main circuit breaker panelboards require an 8.75 in. deep, 26 in. wide box.
c800 A main lug panelboards require an 8.75 in. deep, 26 in. wide box.
Table 9.72: Ground Bars
Ground Bars $ Price Adder
Equipment Ground Bar 38.
Copper Ground Bar (Add to Equipment Ground Bar Price) 52.
Insulated/Isolated Ground Bar (Add to Equipment Ground Bar Price) 86.
Table 9.73: Name Plates
Name Plates $ Price Adder
Standard white face/black letter laminated bakelite, 1 in. x 3.5 in.,
adhesive-backed or screw mountable with screws in a bag assembly
(Price includes engraving)
78.
Table 9.74: Copper Bus Bars
Copper Bus Bars $ Price Adder
100 A, 250 A 458.
400 A 624.
600 A, 800 A Standard
Table 9.75: Copper Neutral
Copper Neutral $ Price Adder
100–600 A 132.
800 A 176.
Table 9.76: 200% Rated Neutrals
Panelboards with 200% rated neutrals are available with sub-feed lugs,
feed-through lugs, and main circuit breakers
Add Per Panel
$ Price
250 A 769.
400 A 950.
600 A 1262.
800 A 1894.
Table 9.77: NF Main Neutral Conductors—Required Size and Quantity
Panelboard
Ampacity Neutral Conductors Required cActual Lug Wire Range
125 (2) 1/0 Cu or (2) 1/0 Al (2) #6-2/0
250 (2) 4/0 Cu or (2) 300 kcmil Al (2) #6-350 kcmil
400 A (4) 250 kcmil Al or
(4) 3/0 Cuor (2) 600 kcmil Al
(2) 1/0-300 kcmil or
(1) 1/0-750 kcmil
600 (4) 500 kcmil Al or (4) 350 kcmil Cu (2) 1/0-750 kcmil
Table 9.78: Metal Directory Frame
Metal Directory Frame $ Price Adder
Not available with LC/LI main circuit breaker
(Replaces standard plastic stick-on directory pouch) 140.
Table 9.79: Hinged Door-in-Door Trim
Hinged Door-in-Door Trim Add Per Panel
$ Price
Hinged Door-in-Door Trim has piano hinge down one side.
Inner door has a lock, outer door is retained with screws 646.
Hinged Door-in-Door with Outer Door Lock in place of screws 836.
Table 9.80: Weatherproof or Dusttight Cabinets (Type 3R, 5, 12)
Weatherproof or Dusttight Cabinets —Type 3R, 5, 12 $ Price Adder
(Not available with panelboards having
LC/LE/LI/LX/LXI main circuit breakers) 1516.
Table 9.81: Optional Factory Assembled Lugs for Main Lug Interiors
Main Lug Interiors $ Price Per Pole Adder
100 A 225 A 400 A 600 A 800 A
Aluminum Compression Lugs 58. 58. 90. 118. 200.
Copper Mechanical Lugs 70.108.148.168.196.
Copper Compression Lugs 70.108.148.168.316.
Table 9.82: Optional Factory Assembled Lugs for Main Circuit Breaker
Interiors
Main Circuit Breaker Interiors $ Price Per Pole Adder
H Frame J Frame LA Frame LC Frame
Aluminum Compression Lugs 59. 98. 128. 262.
Copper Mechanical Lugs 70. 108. 148. 168.
Copper Compression Lugs 70. 108. 148. 168.
Table 9.83: Surgelogic™ Hard Bus SPD—Model IMA d
Surge Current
Rating kA
Volt age
208Y/120 V
3Ø4W
240/120 V
3Ø4W High Leg
480Y/277 V
3Ø4W
100 11970. 11970. 12890.
120 12548. 15654. 13340.
160 13807. 13807. 14623.
200 17992. 17992. 20508.
240 20583. 20583. 23598.
dPanelboard box height with SPD unit—Contact your local Schneider Electric
representative or distributor.
Table 9.84: Surgelogic SPD Options
Surgelogic SPD Options $ Price
Surge Counter Standard
Dry Contacts Standard
Remote Monitor 2588.
PE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-18 © 2012 Schneider Electric
All Rights Reserved
NQ/NF Merchandised Single Row (Column Width) Panelboards
Class 1640 / Refer to Catalog 1670CT0701, 1640CT0801
NQ Single-Row (Column-width)—240 Vac Bolt-on
(60 A Max. Branch Circuit Breaker)
NQ Application Data
Application: For use on ac only. Meet Federal Specification W-P-115c,
Type 1, Class 1. UL Listed.
Service: 1Ø3W, 3Ø3W, 3Ø4W,
3 Grd. “B” Ø—240 Vac max.
AIR: See the tables starting on Digest page 7-2.
Mains: Type NQ—Bolt-on main lugs: 100 A, 225 A
•Main circuit breaker: 100 A—QOU, 225 A—QB
•See the tables starting on Digest page 7-2 for main circuit breaker
interrupt ratings. See catalog for terminal lug data.
•Main circuit breakers with higher interrupt ratings are available as factory
assembled panelboards.
Branches: Bolt-on QOB, 60 A maximum. QOB 10-60 A 1-, 2- and 3-pole.
See Digest page 9-10 for branch circuit breaker terminal data. QOB-VH and
QHB branch circuit breakers are also available as factory assembled.
Cabinet: Front—Screw cover. Box—galvanized steel with removable endwalls.
Gutters:
•100 A—4 in. min. mains end, 3 in. min. opposite mains
•225 A—10 in. min. mains end, 5 in. min. opposite mains
NF Single-Row (Column-width)—480Y/277 Vac Bolt-on
(60 A Max. Branch Circuit Breaker)
NF Application Data
Application: For use on ac only. Meet Federal Specification W-P-115c, Type
1, Class 1. UL Listed.
Service: 480Y/277 Vac, 3Ø4W
AIR: See the tables starting on Digest page 7-2
Mains:
Type NF–Bolt-on main lugs: 125 A, 225 A
•Main circuit breaker: 100 A—FA, 100 A—HD, 225 A—JD. See the tables
starting on Digest page 7-2 for main circuit breaker interrupt rating. See
the catalog section for terminal lug data.
•Main circuit breakers with higher interrupt ratings are available as factory
assembled panelboards.
Branches: EDB, EDG, or EDJ, 60 A maximum. See Digest page 9-15 for
branch circuit breaker catalog numbers, List Prices and terminal data.
Cabinet: Front—Screw cover. Box—galvanized steel with removable
endwalls.
Gutters:
•100 A—4 in. min. mains end, 3 in. min.opposite mains
•225 A—10 in. min. mains end, 5 in. min. opposite mains
Table 9.85: NQ Single-Row (Column-width)—240 Vac Bolt-on a
Max.
No. of
Poles
Mains
Rating
Total
$ Price
(Box
Interior
and
Front)
Box and Interior with Solid Neutral
(8.625 in. W. x 5 in. D.)
(Order branch circuit breakers separately)
Front
(Surface Mount)
Catalog Number $ Price Box Height
(In.)
Catalog
Number $ Price
1 Phase 3-Wire Main Lugs Only
30 225 1669. NQ830L2C 1298. 45 LX45TS 371.
Main Circuit Breaker—2-pole
20 100 1818. NQ820B1C 1452. 40 LX40TS 366.
3 Phase 4-Wire Main Lugs Only
30 100 1608. NQ8430L1C 1242. 40 LX40TS 366.
42 225 1938. NQ8442L2C 1458. 58 LX58TS 480.
Main Circuit Breaker—3-pole
30 100 2363. NQ8430B1C 1992. 45 LX45TS 371.
42 225 4961. NQ8442B2C 4416. 62 LX62TS 545.
a60 A Maximum Branch—Copper Bus Standard.
Table 9.86: Cable Troughs and Pull Boxes
Cable Troughs (L=Length) bPull Boxes with Solid Neutral
L
(In.)
8.625 in. x 5 in.
Catalog Number $ Price S/N
Terminals
Catalog
Number $ Price
36 MTX836 590.
42 MPX81542 479.
48 MTX848 651.
56 MTX856 753.
66 MTX866 753.
bCable troughs are standard with a trough barrier.
Table 9.87: NF Single-Row (Column-width)—480Y/277 Vac Bolt-on
Max. No.
of Poles
Mains
Rating
Total $ Price
(Box Interior
and Front)
Box and Interior with S/N
(8.625 in. W. x 5.625 in. D.)
Front
(Surface Mount)
Catalog
Number $ Price
Box
Height
(In.)
Catalog
Number $ Price
Main Lugs Only—3 Phase 4-Wire
30 125 2410. NF8430L1C 2009. 59 NC59TS 401.
42 225 3281. NF8442L2C 2759. 71 NC71TS 522.
Main Circuit Breaker—3-pole
30 100 3767. NF8430M1C 3246. 65 NC65TS 521.
NF8430M1HDC
42 225 6660. NF8442M2JDC 6042. 85 NC85TS 618.
Table 9.88: Cable Troughs and Pull Boxes
Cable Troughs (L=Length) cPull Boxes with Solid Neutral
L
(In.)
8.625 in. x
5.625 in.
Catalog
Number d
$ Price S/N
Terminals
Catalog
Number $ Price
36 NTX836 590.
42 MPX81542 479.
48 NTX848 651.
56 NTX856 753.
66 NTX866 753.
cCable troughs are standard with a trough barrier.
dBox width = 8.625 in.; width at front, including flange, is 9.625 in..
8 in.
5⁄8
20 in.
15 in.
Panel
Height
Solid
Neutral
Bar
Pull Box
(Cover Removed)
Cable
Trough
Column
Width
Lighting
Panelboard
Cable
Trough
Length
PE1A Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-19
NQ/NF Factory Assembled Single Row (Column Width) Panelboards
Class 1640 / Refer to Catalog 1670CT0701, 1640CT0801
NQ Single Row (Column-Width)—240 Vac Bolt-On Factory Assembled Pricing
NF Single Row (Column-Width)—480Y/277 Vac 3Ø4W Bolt-on Factory Assembly Pricing
Table 9.89: Base Price with Solid Neutral
Mains Rating
$ Price
Main Lugs Main Circuit Breaker (Circuit Breaker Interrupt Rating—see Digest pages 7-2 through 7-5
2-Pole 3-Pole Circuit Breaker 2-Pole 3-Pole Circuit Breaker 2-Pole 3-Pole
100 A 720. 832.
QOB 1254. 1562. ———
QB — 2800. ———
QD — 3434. QG — 4090.
225 A 772. 912. QB — 2800. ———
QD — 3434. QG — 4090.
Note: Copper bus —standard.
Equipment Ground Bar $ Price adder—$38.00.
Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder—$52.00.
Table 9.90: Branch Circuit Breakers (price per breaker)
Circuit Breaker
Ampere Rating
$ Price
1-Pole 120 Vac 2-Pole 120/240 Vac 2-Pole 240 Vac 3-Pole 240 Vac
Space Only
All Space Only Except Below 28. 58. 58. 86.
10,000 AIR—Branch Circuit Breakers—QOB, QOB-H
15–60 A 68. 134. 260. 352.
10,000 AIR—Qwik-Guard™—Class A—QOB-GFI
15–30 A 272. 488. ——
40–60 A — 488. ——
Specialty Branch Circuit Breakers (10,000 AIR)
For High Intensity Discharge Lighting—QO-HID, QOB-HID
15–30 A 78. 148. —376.
40–50 A 78. 148. ——
High Magnetic Trip (For applications subject to high initial inrush)—QO-HM, QOB-HN
15–20 A 68. ———
Provides 30 mA Equipment Protection—QO-EPD, QOB-EPD
15–30 A 462. 828. ——
(High Interrupting Capacity)
22,000 AIR Branch Circuit Breakers—QO-VH, QOB-VH
15–30 A 92. 212. —462.
35–60 A — 212. —462.
22,000 AIR—Qwik-Guard—Class A—QO-VHGFI, QOB-VHGFI
15–30 A 294. ———
Table 9.91: Base Price with Solid Neutral
Mains
Rating
Main Lugs Main Circuit Breaker (Circuit Breaker Interrupt Rating —see Digest pages 7-3 through 7-4
Standard IC HIC Extra HIC I-Limiter™
Circuit Breaker $ Price Circuit
Breaker
$ Price Circuit
Breaker
$ Price Circuit
Breaker
$ Price
2-Pole 3-Pole 2-Pole 3-Pole 2-Pole 3-Pole 2-Pole 3-Pole 2-Pole 3-Pole
100 A —
1074.
FA — 2184. FH — 3044. ——————
—HD —2842. HG —3792. HJ —4374. FI — 7392.
125 A — — 3222. —4172. —4754. KI — 13150.
150 A — 1272. HD — 3222. HG — 4172. HJ — 4754. KI —13150.
225 A — JD — 4784. JG — 5982. JJ — 8902. —
Note: Copper bus—standard.
Copper Neutral $ Price adder—$132.00.
Equipment Ground Bar $ Price adder—$38.00.
Copper Equipment Ground Bar (Add to Equipment Ground Bar $ Price) $ Price adder—$52.00.
Table 9.92: Branch Circuit Breakers (price per breaker)
Circuit Breaker
Ampere Rating
$ Price
Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR
@480Y/277 Vac ED Bolt-on Branch
High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR
@480Y/277 Vac EG Bolt-on Branch
Extra High Interrupting 100,000 AIR @ 65,000 AIR @
480Y/277 Vac EJ Bolt-on Branch
1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole
15–60 A 192. 442. 748. 324. 746. 1264. 518. 1196. 2024.
Space Only 42. 84. 126. 42. 84. 126. 42. 84. 126.
Table 9.93: EDB-EPD Equipment Protection Device Branch Circuit Breakers
Circuit Breaker
Ampere Rating
$ Price
Standard Interrupting 25,000 AIR @ 240 Vac, 18,000 AIR
@480Y/277 Vac ED Bolt-on Branch
High Interrupting 65,000 AIR @ 240 Vac, 35,000 AIR
@480Y/277 Vac EG Bolt-on Branch
Extra High Interrupting 100,000 AIR @ 65,000 AIR @
480Y/277 Vac EJ Bolt-on Branch
1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole
15–60 A 1472. —— 1596. —— 1788. ——
PE-1 Discount
Schedule
9-20 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
9PANELBOARDS
I-Line™ and QMB
Panelboards
Pricing Procedure and Examples
Class 2110, 4620 / Refer to Catalog 2110CT9701, 4620CT9601
I-Line Merchandised Pricing Procedure
1. Select the appropriate branch circuit breakers and accessories based on the required ampacity and AIR ratings from
Digest pages 9-24 through 9-30.
2. Determine the total mounting inches required by the branch circuit breakers. Pay close attention to the interior types and
any branch mounting restrictions by referring to panel layouts on Digest pages 9-21 and 9-22. For example, larger frame
circuit breakers may mount in only one side of the panel due to physical sizes. Therefore, for larger size branches, you may
only be able to consider one half of the total mounting inches available.
3. Select proper main lug interior or main circuit breaker interior from Digest page 9-21 or 9-22 based on the mains ampacity
and branch requirements from step 2.
4. Select blanks from the Accessories table on Digest page 9-23 as required to cover unused mounting space.
5. Select appropriate box and front from Digest page 9-21 or 9-22 to accommodate panel interior selected in step 3.
6. Apply appropriate discount schedule.
I-Line Factory Assembled Pricing Procedure
1. Select price for main lugs or main circuit breaker from Base Price tables on Digest page 9-31. Include solid neutral and
ground bar when required.
2. List branch circuit breakers and determine total mounting inches required. Include space only charge and mounting inches
as required. Price branches from Digest page 9-32.
3. If total space required exceeds the maximum listed, price as two or more panels and add price for sub-feed lugs, so
installer can cable between sections.
4. Add price for special features from Digest page 9-34.
5. For complete price, total all prices. Order panel by description.
6. Apply appropriate discount schedule.
QMB Factory Assembled
QMB Panelboards—Method of Pricing
1. Make a sketch with main lugs or main switch at the top or bottom.
2. List required branch devices (switches and circuit breaker units). Include ampere rating, number of poles, and unit
mounting height from the appropriate table on Digest pages 9-35 and 9-36.
3. 30–60 twin units are the same price as 600 V 60–60 twin units.
4. 30–100 and 60–100 twin units are the same price as 600 V 100–100 twin units.
5. List solid neutral from Digest page 9-36 if required. No unit mounting height is required.
6. List mains ampere rating, voltage, number of poles, and unit mounting space from the appropriate table on 9-36.
7. If total unit mounting height of branch devices exceeds maximum mounting space of the mains, price as two or more
panelboards, adding sub-feed lugs or feed-thru lugs from the appropriate table on Digest page 9-36.
8. Insert at the right of each item the price from the appropriate table, including any accessories. The sum will be the
complete panelboard price including the cabinet.
9. Specify H, R, or J fuse clips.
Table 9.94: I-Line Merchandised Pricing Example
600 Vac, 3Ø3W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door.
Description Catalog No. Digest Page No. $ Price
400 Amp MLO Interior HCM32734 9-21 2408.
4 Piece Surface Trim Without Door HCM73TS 9-21 699.
Type 1 Enclosure HC3273B 9-21 243.
(8) 60/3 FA36060 9-25 7764.
one 100/2 FA26100AC 9-25 947.
one 4.5 in. Blanks HNM4BL 9-23 126.
one 1.5 in. Blank HNM1BL 9-23 44.
Total Price 12231.
Table 9.95: I-Line Factory Assembled Pricing Example
600 Vac, 3Ø3W, 400 A, MLO, 14k AIR, Type 1 enclosure, 4 piece surface trim without door.
Description Digest Page No. $ Price
400 A MLO Base Price 9-31 2799.
(8) 60/3 9-32 12072.
one 100/2 9-32 1446.
(3) 250/3 9-32 17100.
Total Price 33417.
Table 9.96: QMB Factory Assembled Pricing Example
600 Vac, 3Ø3W, 400 A, Fusible 10k AIR, Type 1 Enclosure
Branches Digest Page No. $ Price
400 A MLO Base Price 9-36 2016.
(4) 60/3 9-36 4338.
one 100/3 9-36 3411.
one 30/3 — —
Total Price 9765.
Example pricing only Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-21
I-Line™ Merchandised
Panelboards
600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701
TYPE HCN
225 A max. (240 V max.) branch
circuit breaker QB, QD, QG, QJ
150 A max. branch circuit
breaker FA, FH, FY, HD, HG, HJ,
HL l
Box Size:
26 in. Wide, 6.5 in. Deep
TYPE HCM
250 A max. branch circuit
breaker
FA, FH, FY, FI, QB, QD, QG, QJ,
HD, HG, HJ, HL, JD, JG, JJ, JL
Box Size:
32 in. Wide, 8.25 in. Deep
TYPE HCP-SUh
800 A max. main circuit breaker
600 A max. branch circuit
breaker
FY, FA, FH, FI, KI, LA, LD, LG,
LJ, LL, LH, LC, LX, LI, LXI, LE,
MG, MJ, PG, PJ, PL, PGC, PJC,
PLCj, QB, QD, QG, QJ, HD,
HG, HJ, HL, JD, JG, JJ, JL
Box Size:
26 in. Wide, 9.5 in. Deep
S
N
600 A Max. Main Lugs
or
400 A Max. Main Breaker
1⁄2 Total
Breaker
Mounting
Space
Each
Side
FA, FH
FY
HD, HG
HJ, HL
QB, QD
QG, QJ
FA, FH
FY
HD, HG
HJ, HL
QB, QD
QG, QJ
HD, HG
HJ, HL
JD, JG
JJ, JL
HD, HG
HJ, HL
JD, JG
JJ, JL
800 A Max. Main Lugs
or
800 A Max. Main Breaker
S
N
1⁄2 Total
Breaker
Mounting
Space
Each
Side
FA, FH
FI, FY
QB, QD
QG, QJ
FA, FH
FI, FY
QB, QD
QG, QJ
S
N
800 A Max. Main Lugs
or
800 A Max. Main Breaker
FY, FA, FH, FI
HD, HG, HJ, HL
QB, QD, QG, QJ
JD, JG, JJ, JL, KI
MG, MJ, PG, PJ, PL
PGC, PJC, PLC
Table 9.97: Interiors, Boxes and Fronts
(100 A and 225 A interiors include solid neutral, all others without solid neutral. Order solid neutral from 9-23)
Total Circuit Breaker
Mounting Space (In.)
Mains Ampere Rating
Complete
Surface $ Price
(4 Piece Trim)
(Less Branch
Circuit
Breakers)
Interior Assembly
(Less Branch
Circuit Breakers)
Front aBox c
Box Height (In.)
4 Piece Trim
Without Door bTrim With Door Type 1
NEMA
3R/5/12d
(Includes Front)
Type 1
$ Price
Type
3R/
5/12
$ Price
Catalog
Number
$
Price
Catalog
Number
$
Price
Catalog
Number
$
Price
Catalog
Number
$
Price
Catalog
Number
$
Price
HCN Main Lugs Only
3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i
27
225 A 2171. 4004. HCN14522N 1593.
HCN52T( ) 335. HCN52T( )D 411. HC2652B 243. HC2652WP 2411. 52400 A 2195. 4028. HCN14524 1617.
600 A 2392. 4225. HCN14526 1814.
45
225 A 2674. 4402. HCN23652N 1991.
HCN65T( ) 440. HCN65T( )D 530. HC2665B 243. HC2665WP 2411. 65400 A 2702. 4430. HCN23654 2019.
600 A 2960. 4688. HCN23656 2277.
63
225 A 3135. 4709. HCN32742N 2298.
HCN74T( ) 594. HCN74T( )D 717. HC2674B 243. HC2674WP 2411. 74400 A 3156. 4730. HCN32744 2319.
600 A 3396. 4970. HCN32746 2559.
81
225 A 3548. 6233. HCN41832N 2552.
HCN83T( ) 753. HCN83T( )D 890. HC2683B 243. HC2683WP 3681. 83400 A 3564. 6249. HCN41834 2568.
600 A 3824. 6509. HCN41836 2828.
99
225 A 4175. 6767. HCN50922N 3086.
HCN92T( ) 846. HCN92T( )D 1001. HC2692B 243. HC2692WP 3681. 92400 A 4341. 6933. HCN50924 3252.
600 A 4434. 7026. HCN50926 3345.
HCN Main Circuit Breaker ek
Includes 3-pole, vertically mounted main circuit breaker—Suitable for use as service equipment
27 400 A 6649. 8377. HCN14654M 5966.
HCN65T( ) 440. HCN65T( )D 530. HC2665B 243. HC2665WP 2411. 65
36 100 A 3860. 5588. HCN18651MN 3177.
225 A 5303. 7031. HCN18652MN 4620.
45 400 A 7287. 8861. HCN23744M 6450.
HCN74T( ) 594. HCN74T( )D 717. HC2674B 243. HC2674WP 2411. 74
54 100 A 4323. 5897. HCN27741MN 3486.
225 A 5759. 7333. HCN27742MN 4922.
63 225 A 6068. 8753. HCN32832MN 5072. HCN83T( ) 753. HCN83T( )D 890. HC2683B 243. HC2683WP 3681. 83
400 A 7836. 10521. HCN32834M 6840.
81 400 A 8154. 10746. HCN41924M 7065. HCN92T( ) 846. HCN92T( )D 1001. HC2692B 243. HC2692WP 3681. 92
90 225 A 6590. 9182. HCN45922MN 5501.
HCM Main Lugs Only
3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i
27
225 A 2279. 4566. HCM14482N 1644.
HCM48T( ) 392. HCM48T( )D 483. HC3248B 243. HC3248WP 2922. 48
400 A 2404. 4691. HCM14484 1769.
600 A 3175. 5462. HCM14486 2540.
800 A 3709. 5996. HCM14488 3074.
45
225 A 2795. 5717. HCM23642N 2036.
HCM64T( ) 516. HCM64T( )D 633. HC3264B 243. HC3264WP 3681. 64
400 A 2891. 5813. HCM23644 2132.
600 A 3530. 6452. HCM23646 2771.
800 A 4041. 6963. HCM23648 3282.
63
225 A 3263. 6002. HCM32732N 2321.
HCM73T( ) 699. HCM73T( )D 864. HC3273B 243. HC3273WP 3681. 73
400 A 3350. 6089. HCM32734 2408.
600 A 3921. 6660. HCM32736 2979.
800 A 4644. 7383. HCM32738 3702.
99
225 A 4205. 7918. HCM50912N 2966.
HCM91T( ) 996. HCM91T( )D 1217. HC3291B 243. HC3291WP 4952. 91
400 A 4281. 7994. HCM50914 3042.
600 A 4586. 8299. HCM50916 3347.
800 A 5321. 9034. HCM50918 4082.
HCM Main Circuit Breaker ek
Includes 3-pole, vertically mounted main circuit breaker—Suitable for use as service equipment.
27 400 A 7563. 10485. HCM14644M 6804. HCM64T( ) 516. HCM64T( )D 633. HC3264B 243. HC3264WP 3681. 64
36
225 A 5582. 8504. HCM18642MN 4823.
600 A 11648. 10706. HCM18736MP 10706. HCM73T( ) 699. HCM73T( )D 864. HC3273DB9m243. Use HCP — —
800 A 14549. 13607. HCM18738MP 13607.
45 400 A 8007. 10746. HCM23734M 7065. HCM73T( ) 699. HCM73T( )D 864. HC3273B 243. HC3273WP 3681. 73
54 225 A 5969. 8708. HCM27732MN 5027.
72 600 A 12377. 11138. HCM36916MP 11138. HCM91T( ) 996. HCM91T( )D 1217. HC3291DB9m243. Use HCP — —
800 A 15431. 14192. HCM36918MP 14192.
81 400 A 9315. 13028. HCM41914M 8076. HCM91T( ) 996. HCM91T( )D 1217. HC3291B 243. HC3291WP 4952. 91
HCP-SU g Universal Single Row Main Lugs or Main Circuit Breaker k
3-pole—Suitable for use as service equipment when provided with a main circuit breaker. i
54 800 5858. 9466. HCP54868SU 4514. HC2686T( )4P 1101. HC2686T( )HRf1658. HC2686DB 243. HC2886WP 4952. 86
aAdd “F” for flush mount, “S” for surface mount.
bAdd-on door kit available from Peru. Example: For HCM48TS surface trim kit, order HCM48DS door kit.
cFor Type 1 applications, order interior, front, and box. For Type 3R/5/12 applications, order interior and box only. The front is included with the box.
dRemove drain screws for Type 3R rating.
eBottom feed standard.
fHinged trim with door.
gFor main lugs panel, order sub-feed lug kit and back-feed as main lugs.
hFor main circuit breaker panel, order plug-on I-Line type PG, PJ, PL, MG, or MJ circuit breakers from 9-28 through 9-30 and backfeed as the main breaker
(order solid neutral from 9-22).
iSuitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided
and the panelboard is not used as a lighting and appliance branch circuit panelboard.
jPG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80%
and 100% rated. “C” suffix denotes a 100% rating.
kCircuit breaker interrupt ratings, starting on Digest page 7-2.
lI-Line Surgelogic SPD not available.
mDB9 box is 9.5 inches deep.
PE1A Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-22 © 2012 Schneider Electric
All Rights Reserved
I-Line™ Merchandised
Panelboards
600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701
TYPE HCP
800 A max. branch
circuit breaker
FAa, FH, FI, FY, QB, QD, QG,
QJ, HD, HG, HJ, HL, JD, JG, JJ,
JL, KI, LA, LD, LG, LJ, LL, LH,
LC, LI, LX, LXI, LE, MG, MJ,
PG, PJ, PL, PGC, PJC, PLCb
Box Size:
42 in. Wide, 9.5 in. Deep
aFA and JDA circuit breakers
with field installable ground
fault kits may be mounted in
type HCP, HCP-SU, and
HCR-U panelboards as
shown, and require L-frame
mounting space.
bPG, PJ, and PL circuit
breakers are available
with both thermal-
magnetic equivalent and
Micrologic trip. The
Micrologic circuit breakers
are available 80% and
100% rated. “C” suffix
denotes a 100% rating.
TYPE HCR-U Universal
Mains
1200 A max. branch
circuit breaker
FAc, FH, FI, FY, QB, QD, QG,
QJ, HD, HG, HJ, HL, JD, JG, JJ,
JL, KI, LA, LD, LG, LJ, LL, LH,
LC, LI, LX, LXI, LE, MG, MJ,
PG, PJ, PL, PGC, PJC, PLC,
RGC, RJC, RLCde
Box Size:
44 in. Wide, 9.5 in. Deep
cFA and JDA circuit
breakers with field
installable ground fault kits
may be mounted in type
HCP, HCP-SU, and HCR-
U panelboards as shown,
and require L-frame
mounting space.
dWhen RL main circuit
breakers with equipment
ground fault are applied on
a 3Ø4W system, order
solid neutral catalog
number HCR12SNCT.
The HCR12SNCT
includes a neutral current
transformer.
ePG, PJ, and PL circuit
breakers are available
with both thermal-
magnetic equivalent and
Micrologic trip. The
Micrologic circuit breakers
are available 80% and
100% rated. “C” suffix
denotes a 100% rating.
FI, KI, JD
JG, JJ, JL FI, KI, JD
JG, JJ, JL
1200 A Max. Main Lugs
or
800 A Max. Main Breaker
LC, LI, LX
LXI, LE
QB, QD
QG, QJ
FA, FH, FY
HD, HG
HJ, HL FA, FH, FY
HD, HG
HJ, HL
MG, MJ, PG,
PJ, PL, PK, PGC
PJC, PKC, PLC
1⁄2 Total
Breaker
Mounting
Space
Each
Side
QB, QD
QG, QJ
S
N
LD, LG, LJ
LL, LA, LH
RG, RJ, RK,
RL, RGC, RJC
RKC, RLC
1⁄2 Total
Breaker
Mounting
Space
Each
Side
LD, LG, LJ
LL, LA, LH
LC, LI, LX
LXI, LE
QB, QD
QG, QJ
QB, QD
QG, QJ
1200 A Max. Main Lugs or
1200 A Max. Main Breaker
MG, MJ
PG, PJ, PK,
PL, PGC, PJC,
PKC, PLC
FI, KI, JD
JG, JJ, JL
FI, KI, JD
JG, JJ, JL
FA, FH, FY
HD, HG
HJ, HL
FA, FH, FY
HD, HG
HJ, HL
S/N
Table 9.98: (1200 A Interiors Include solid neutral, all others without solid neutral.
Order solid neutral from 9-23.)
Total
Circuit
Breaker
Mtg.
Space
(In.)
Mains Amp.
Rating
Max.
No. of
LC, MJ,
PL, RL
Circuit
Breakers
Complete
Surface
$ Price
(4 Piece Trim)
(Less Branch
Breakers)
Interior Assembly
(Less Branch Circuit Breakers)
Front f
Box hBox
Height
(In.)
4 Piece Trim
Without Door gTrim With Door
Type 1 Catalog
Number
$
Price
Catalog
Number
$
Price
Catalog
Number
$
Price
Catalog
Number
$
Price
HCP Main Lugs Only—3-pole
Suitable for use as service equipment when provided with a main circuit breaker. i
27
400
1PL
2751. HCP14504 1902.
HCW50T( ) 606. HCW50T( )D 743. HC4250DB 243. 50
600 3513. HCP14506 2664.
800 4521. HCP14508 3672.
1200 6365. HCP145012N 5516.
45
400
2PL
3212. HCP23594 2298.
HCW59T( ) 671. HCW59T( )D 827. HC4259DB 243. 59
600 3860. HCP23596 2946.
800 4874. HCP23598 3960.
1200 7133. HCP235912N 6219.
63
400
3PL
3795. HCP32684 2706.
HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 68
600 4476. HCP32686 3387.
800 5309. HCP32688 4220.
1200 7763. HCP326812N 6674.
99
400
5PL
4716. HCP50864 3372.
HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 86
600 5208. HCP50866 3864.
800 6194. HCP50868 4850.
1200 8529. HCP508612N 7185.
HCP Main Circuit Breakerj—Includes 3-pole
Vertically mounted main circuit breaker—Suitable for use as service equipment.
36 600 2LC 12179. HCP18686M 11090. HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 68
800 15399. HCP18688M 14310.
72 600 4LC 12987. HCP36866M 11643. HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 86
800 16296. HCP36868M 14952.
HCR-U Universal Main Lugs or Main Circuit Breakerj—3-pole
Suitable for use as service equipment when provided with a main circuit breaker.
For Main Lugs panel, order sub-feed lug kit catalog number S33930 and back feed as main lugs.
For Main Circuit Breaker panel, order plug-on I-Line type PG, PJ, PL, RGC, RJC, or RLCk circuit breakers from pages 9-27 through 9-29,
and back feed as the main circuit breaker. (Order solid neutral separately)
108 l1200 6PL or 3RLC 12557. HCR548612U 11213. HCR86T( )m1101. HCR86T( )D 1344. HC4486DB 243. 86
fAdd “F” for flush mount, “S” for surface mount.
gAdd-on door kit available. Example: For HCW50TS trim kit, order HCW50D door kit.
hSee Digest page 9-23 for 42 in. wide weatherproof enclosures.
iSuitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided
and the panelboard is not used as a lighting and appliance branch circuit panelboard.
jCircuit breaker interrupt ratings, starting on Digest page 7-2.
kWhen RL main circuit breakers with equipment ground fault are applied on a 3Ø4W system, order solid neutral catalog number HCR12SNCT.
The HCR12SNCT includes a neutral current transformer.
l15 in. of mounting space is taken up by the back fed main lug kit or RG, RJ, RL main circuit breaker, leaving 93 in. of branch circuit breaker mounting space.
mAdd-on door kit available. Example: For HCR86TS trim kit, order HCW86D door kit.
Table 9.99: Circuit Breaker / Sub-feed Lug Kit Mounting Space Requirement
Type of Circuit Breaker Maximum
Ampacity
No. of
Poles
Inch Mounting
Requirements Type of Circuit Breaker Maximum
Ampacity
No. of
Poles
Inch Mounting
Requirements
FY 30 A 1 1.5 QB, QD, QG, QJ 225 A 3 4.5
FA, FH
100 A
1 1.5 JD, JG, JJ, JL, KI, SL250 250 A
2, 3
4.5
FA, FH 2 3 LA, LH, SL400 400 A 6
FA, FH, SL-100 3 4.5 LD, LG, LJ, LL 600 A 6
FI 2, 3 4.5 LC, LI, LXI 600 A 7.5
HD, HG
150 A
23
MG, MJ, MA, MH, SL800, PGC, PJC, PLC 800 A 9HD, HG 3 4.5
HJ, HL 2, 3 4.5 PG, PJ, PL, S33931 1200 A
QB, QD, QG, QJ 225 A 2 3 RG, RJ, RL, RGC, RJC, RLC, S33930 1200 A 15
Table 9.100: Main Circuit Breaker Interiors —Standard Frame
Types n
Main Circuit
Breaker Ampacity
Panelboard
Type
Factory Supplied
Main Circuit Breaker
100 HCN FA36100
225 HCN, HCM JDA36225
400 HCN LAP36400MB
HCM LAP36400MB
600
or
800
HCM, HCP
MGP36600
or
MGP36800
nCircuit breaker interrupt ratings, starting on Digest page 7-2.
Table 9.101: Standard Copper Bus Interiors
Type Main Ampacity
HCN 600
HCM, HCP-SU 800
HCP, HCR-U 800 and Above
Note: Merchandised copper interiors are not available in all ampacities. For
example, if the application calls for a HCN 225 A copper bus interior,
order an HCN 600 A interior .
PE1A Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-23
I-Line™ Merchandised
Panelboards
Accessories
Class 690, 2110 / Refer to Catalog 2110CT9701
Blank Fillers Equipment Ground Bar Solid Neutral
Table 9.102: I-Line Merchandised Panelboard Accessories
Description Catalog No. $ Price
Blank Fillers—1.5 in. (minimum order 3) eHNM1BL 14.30
Blank Fillers—4.5 in. (minimum order 5) eHNM4BL 25.20
Solid Neutral Assemblies
225 A HC2SN 252.00
400 A HC4SNa, HCW4SNb333.00
600 A HC6SNa, HCW6SNb464.00
800 A
HC8SNa, HCW8SNb717.00
HCPSU8SNc1151.00
HCPSU8SNCTc1269.00
1200 A HCW12SNb843.00
1200 A, for use with HCR-U universal panel only HCWM12SNd1151.00
1200 A, Including neutral CT for 3Ø4W systems HCR12SNCTd1269.00
Equipment Ground Bar Kits—HCN PK27GTA 33.80
HCM, HCP, HCR-U PK32DGTA 104.00
Blank Extensions (For replacement purposes)
1.5 in. for mounting on wide side of I-Line panelboard (minimum order 3) eHLW1BL 14.30
4.5 in. for mounting on wide side of I-Line panelboard (minimum order 5) eHLW4BL 25.20
1.5 in. for mounting on narrow side of I-Line panelboard (minimum order 3) eHLN1BL 14.30
4.5 in. for mounting on narrow side of I-Line panelboard (minimum order 5) eHLN4BL 25.20
4.5 in. for mounting on wide side of I-Line panelboard (minimum order 5) eHLW4EBL 25.20
4.5 in. for mounting on narrow side of I-Line panelboard (minimum order 5) eHLN4EBL 25.20
aUsed on Type HCN, HCM.
bUsed on 400 A, 600 A, 800 A, and 1200 A HCP (main lugs), and 600 A and 800 A (main circuit breaker).
cUsed on Type HCP-SU.
dUsed on Type HCR-U.
eBlank extension pricing is per unit. Multiply the list price by the quantity ordered. Note minimum order quantity.
Table 9.103: Blank Extensions
Application
Circuit
Breaker
Mounting
Ht.
Branch
Circuit
Side
Catalog
Number
All applications, except Powerpact H/J
with Micrologic trip unit 5/6
1.5 in. Wide Side HLW1BL
4.5 in. HLW4BL
All applications, except Powerpact H/J
with Micrologic trip unit 5/6
1.5 in. Narrow
Side
HLN1BL
4.5 in. HLN4BL
Only Powerpact H/J circuit breakers
with Micrologic trip unit 5/6 4.5 in. Narrow
Side HLN4EBL
Only Powerpact H/J circuit breakers
with Micrologic trip unit 5/6 4.5 in. Wide Side HLW4EBL
Table 9.104: Panelboard Adapter Kits
Crimp Lug Adapter Kits fI-Line Panelboard Type
HCN HCM HCP, HCR-U g$ Price
400 A HCN400VCA HCM400VCA HCW400VCA 96.
600 A HCN600VCA HCM600VCA HCW600VCA 197.
800 A — HCM800VCA HCW800VCA 284.
1200 A — — HCW1200VCA 491.
fFor use with MLO panel, order VCEL lugs seperately.
gNot for use with P- or R-frame circuit breakers or sub-feed kits S33930 or S33931.
Blank Extensions
Table 9.105: Type 3R/5/12 Enclosures
Catalog Number Interior Type $ Price Dimensions (In.)
H W D
HC4250WP HCP 4952. 50 42 12.95
HC4259WP HCP 4952. 59 42 12.95
HC4268WP HCP 4952. 68 42 12.95
HC4286WP HCP 4952. 86 42 12.95
HC4486WP HCR-U 4952. 86 44 14.50
Table 9.106: Box Extensions
Catalog Number Interior Type Extension $ Price
HC2609DEX (F or S) HCP-SU 9 in. 552.
HC2609EX (F or S) HCN 9 in. 552.
HC3209EX (F or S) HCM 9 in. 552.
HC4212DEX (F or S) HCP 12 in. 641.
HC4406DEX (F or S) HCR-U 6 in. 552.
HC4412DEX (F or S) HCR-U 12 in. 641.
Sub-feed Lug Kits
Table 9.107: Sub-feed Lug Kits hi
Ampere
Rating
Height Catalog
Number $ Price
Max. Short Circuit System Ratings
RMS Symmetrical Amperes Protected by
Circuit Breaker
For Use in I-Line
Panelboard Types
In. (mm) 240 Vac 480 Vac 600 Vac
100 A 4.5 114 SL100 435. 65,000 25,000 18,000 FH HCN, HCM, HCP, HCP-SU
250 A 4.5 114 SL250 435. 125,000 100,000 50,000 JL HCM, HCP, HCP-SU
250 A 4.5 114 SL250 435. 200,000 200,000 100,000 KI
400 A 6 152 SL400j585. 65,000 35,000 25,000 LH HCP, HCP-SU
800 A 9 229 SL800 1731. 65,000 65,000 25,000 MJ HCM, HCP, HCP-SU
1731. 125,000 100,000 50,000 LL
1200 A 9 229 S33931 3500. 100,000 65,000 25,000 MJ, PJ HCP, HCP-SU, HCR-U
1200 A 15 381 S33930 3500. 125,000 100,000 50,000 RL
hPlug-on in same manner as a branch circuit breaker
iFor other ratings, See the I-Line Information Manual, #80043-309-xx.
jSL400 cannot be used in HCM panelboards due to inadequate wire bending space.
Table 9.108: Sub-feed Lug kit terminal data
Catalog No.
(Prefix)
No.
Poles
Ampere
Rating
Std. Lug Kit
Catalog No. Standard Lug Wire Size k
SL100 3 100 A AL100FA #14–1/0 AWG Cu or #12–1/0 AWG Al
SL250 3 250 A — #4 AWG–300 kcmil
SL400 3 400 A AL400LA one #1 AWG–600 kcmil or two #1 AWG–250 kcmil
SL800 3 800 A AL900MA (3) #3/0 AWG–500 kcmil
S33931 3 1200 A AL1200P24K (4) #3/0 AWG–500 kcmil
S33930 3 1200 A AL1200R53K (4) #3/0 AWG–600 kcmil
kUnless otherwise specified, wire sizes apply to both aluminum and copper conductors.
For Surgelogic™ I-Line plug-on SPD unit pricing and
information, see Digest pages 6-3 and 6-4.
For field-installable I-Line door kits, see the
Supplemental and Obsolescence Digest, Section 4.
www.schneider-electric.us
9PANELBOARDS
9-24 © 2012 Schneider Electric
All Rights Reserved
Circuit Breakers F-frame, PowerPact D-frame for I-Line™ Panelboards and Switchboards
Class 650, 651
F-frame accessories . . . . . . . . . starting on Supplemental Digest page 3-24
F-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54
F-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-51
PowerPact™ D-frame Mission Critical Circuit Breakers
When the D-frame Mission Critical circuit breaker is used as a main circuit
breaker with QO branch circuit breakers, the D-frame MC will remain closed
during any fault that occurs downstream of the QO circuit breaker up to 30kA
at 208Y/120 Vac.
cD-frame circuit breakers 400 A and below are 100% rated.
D-frame accessories, lugs . . . . . starting on Supplemental Digest page 3-27
D-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
Table 9.109: QO™ Distribution Panel—240 Vac Max. Only Mounts in Type
HCN, HCM, HCP, HCP-SU, or HCR-U I-Line panelboards, 30 A
max. branch circuit breaker. Order QO plug-on circuit breakers
from page 9-34.
Maximum No. 1-pole
QO Circuit Breakers
Phase
Connection
Mounting
Height 2-pole
Catalog
Number
3-pole
Catalog
Number
$ Price
a
In. mm
6AB4.5114HQO206AB —369.
6BC4.5114HQO206BC —369.
6AC4.5114HQO206AC —369.
6 ABC 4.5 114 — HQO306 369.
aIncludes (5) QO1DB dummy circuit breakers.
Table 9.110: Example: FJA, 20 A 1-pole, 277 Vac and 70 A 2- and 3-pole QB 240
Vac. Use phase option number for HD, HG, HJ, HL, JD, JG, JJ, JL,
MG, and MJ.
Phase
Option
Number
Phase
Connection 1-pole 2-pole 3-pole
1 A FJA140201 — —
3 B FJA140203 — —
5 C FJA140205 — —
1 AB — QBA220701 —
2 AC — QBA220702 —
3 BA — QBA220703 —
4 BC — QBA220704 —
5 CA — QBA220705 —
6 CB — QBA220706 —
Standard bABC — — QBA32070
6 CBA — — QBA320706
bThe absence of a phase option number after a 3-pole catalog number will result in an ABC
phase connection.
Table 9.111: Example: FA, 30 A, 480 Vac. Use phase option letters for FH, FI, KI,
LA, LH, LC, and LI.
Phase
Option Letter 1-pole 2-pole 3-pole
A FA14035A — —
B FA14035B — —
C FA14035C — —
AB — FA24030AB —
AC — FA24030AC —
BC — FA24030BC —
ABC — — FA34030
CBA — — FA34030CBA
Table 9.112: Interrupt Ratings (kA)
FA (240 V) FA (480 V) FJ
240 V 10 18 (1P), 25 (2, 3P) 65
277 V — 18 65
480 V — 18 —
600 V — — —
Table 9.113: PowerPact D-frame, 150–600 A–Mission Critical
Circuit Breaker
Cat.alog Number c
Continuous Current
Rating Terminal Wire Range (AWG/kcmil) $ Price
DJA32150W 150 A
#2-600 Cu or #2-500 Al
10867.
DJA32250W 250 A 10867.
DJA32400W 400 A 10867.
DJA32600W 600 A (2) 2/0-350 Cu or (2) 2/0-500Al 17148.
FA/FH, 2-pole
3 in (76 mm)
Mounting Height
FA/FH, 3-pole
4.5 in (114 mm)
Mounting Height
FA/FH, 1-pole
1.5 in (38 mm)
Mounting Height
Table 9.114: F-frame—100 A, Thermal-magnetic (240 Vac)
Ampere
Rating
AC Magnetic
Trip Settings Standard Interrupting Terminal
Wire
Range
Hold Trip Catalog Number $ Price
2-pole, 240 Vac d
15 A
275 600
FA22015( )
398.
AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
20 A FA22020( )
25 A FA22025( )
30 A FA22030( )
35 A
400 850
FA22035( )
AL100FA
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al
40 A FA22040( )
45 A FA22045( )
50 A FA22050( )
60 A
800 1450
FA22060( )
70 A FA22070( )
617.
80 A FA22080( )
90 A 900 1700 FA22090( )
100 A FA22100( )
3-pole, 240 Vac
15 A
275 600
FA32015
572.
AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
20 A FA32020
25 A FA32025
30 A FA32030
35 A
400 850
FA32035
572.
AL100FA
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al
40 A FA32040
45 A FA32045
50 A FA32050
60 A
800 1450
FA32060 572. AL100FA
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al
70 A FA32070 780.
80 A FA32080
90 A 900 1700 FA32090 780. AL100FA
#14–#1/0 AWG Cu
100 A FA32100
d1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase
connection letters as a suffix.
Table 9.115: F-frame—100 A, Thermal-magnetic (480 Vac)
Ampere
Rating
AC Magnetic
Trip Settings Standard Interrupting Extra High Interrupting Terminal Wire Range
Hold Trip Catalog
Number $ Price Catalog
Number $ Price FY/FA
Lugs FJ/FC Lugs
1-pole, 277 Vac, 125 Vdc e
15 A
275 600
FY14015( )f
149.
FJA14015( )
651.
AL50FA
#14-#4
AWG Cu, or
#12-#4
AWG Al
AL30FD
#12–#6
AWG Al, or
#14–#6
AWG Cu
20 A FY14020( )fFJA14020( )
25 A FY14025( )fFJA14025( )
30 A FY14030( )fFJA14030( )
35 A
400 850
FA14035( )g
302.
FJA14035( )
651.
AL100FA
#14–#1/0
AWG Cu or
#12–#1/0
AWG Al
AL100FD
#12–#2/0
AWG Al
or
#14–#2/0
AWG Cu
40 A FA14040( )gFJA14040( )
45 A FA14045( )gFJA14045( )
50 A FA14050( )gFJA14050( )
60 A
800 1450
FA14060( )g
302.
FJA14060( ) 651.
70 A FA14070( )gFJA14070( ) 720.
80 A FA14080( )g——
90 A 900 1700 FA14090( )g302. ——
100 A FA14100( )g——
2-pole, 480 Vac, 250 Vdc efg
15 A
275 600
FA24015( )
651.
——AL50FA
#14–#4
AWG Cu or
#12–#4
AWG Al
CU30FA4
one #14–
#10 AWG
Cu only
20 A FA24020( ) — —
25 A FA24025( ) — —
30 A FA24030( ) — —
35 A
400 850
FA24035( )
651.
——
AL100FA
#14–#1/0
AWG Cu or
#12–#1/0
AWG Al
AL100FA4
one #14–#3
AWG Cu
or
one #12–#1
AWG Al
40 A FA24040( ) — —
45 A FA24045( ) — —
50 A FA24050( ) — —
60 A
800 1450
FA24060( ) 651. ——
70 A FA24070( ) 833. ——
80 A FA24080( ) — —
90 A 900 1700 FA24090( ) 833. ——
100 A FA24100( ) — —
3-pole, 480 Vac, 250 Vdc e
15 A
275 600
FA34015
833.
——AL50FA
#14–#4
AWG Cu or
#12–#4
AWG Al
CU30FA4
one #14–
#10 AWG
Cu only
20 A FA34020 ——
25 A FA34025 ——
30 A FA34030 ——
35 A
400 850
FA34035
833.
——
AL100FA
#14–#1/0
AWG Cu or
#12–#1/0
AWG Al
AL100FA4
one #14–#3
AWG Cu
or
one #12–#1
AWG Al
40 A FA34040 ——
45 A FA34045 ——
50 A FA34050 ——
60 A
800 1450
FA34060 833. ——
70 A FA34070 996. ——
80 A FA34080 ——
90 A 900 1700 FA34090 996. ——
100 A FA34100 ——
e1- and 2-pole circuit breaker catalog numbers are completed by adding the required phase
connection letters as a suffix.
fRated 277 Vac 15 and 20 A FY circuit breakers are rated for switching duty (SWD). 15, 20,
25, and 30 A FA I-Line circuit breakers are also available (no SWD rating).
gRated 277 Vac, 125 Vdc, except FY circuit breakers, which have no dc rating.
15–30 A circuit breakers suitable for use with 60 oC or 75 oC conductors. 35–100 A circuit
breakers are suitable for use with 75 oC conductors.
DE2 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-25
Circuit Breakers F-frame, PowerPact Q-frame for I-Line™ Panelboards and Switchboards
Class 650, 734, 820
FI36100
2- and 3-pole
4.5 in (114 mm)
Mounting Height
QB/QD/QG/QJ
Mounting Height:
2-pole—3 in (76 mm)
3-pole—4.5 in (114 mm)
Table 9.116: F-frame—100 A, Thermal-magnetic (600 Vac)
Ampere
Rating
AC Magnetic
Trip Settings Standard Interrupting High Interrupting Current Limiting Terminal
Wire
Range
Hold Trip Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price
1-pole, 277 Vac, 125 Vdc a
15 A
275 600
— — FH16015( )
507.
—— AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
20 A — — FH16020( ) — —
25 A — — FH16025( ) — —
30 A — — FH16030( ) — —
35 A
400 850
— — FH16035( )
507.
——
AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al
40 A — — FH16040( ) — —
45 A — — FH16045( ) — —
50 A — — FH16050( ) — —
60 A
800 1450
— — FH16060( ) 507. ——
70 A — — FH16070( ) 563. ——
80 A — — FH16080( ) — —
90 A 900 1700 — — FH16090( ) 563. ——
100 A — — FH16100( ) — —
2-pole, 600 Vac, 250 Vdc a
15 A
275 600
FA26015( )
780.
FH26015( )
1214.
—— AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
20 A FA26020( ) FH26020( ) FI26020( ) 2763.
25 A FA26025( ) FH26025( ) — —
30 A FA26030( ) FH26030( ) FI26030( ) 2763.
35 A
400 850
FA26035( )
780.
FH26035( )
1214.
——
AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al
40 A FA26040( ) FH26040( ) FI26040( ) 2763.
45 A FA26045( ) FH26045( ) — —
50 A FA26050( ) FH26050( ) FI26050( ) 2763.
60 A
800 1450
FA26060( ) 780. FH26060( ) 1214. FI26060( )
2763.70 A FA26070( ) 947. FH26070( ) 1452. FI26070( )
80 A FA26080( ) FH26080( ) FI26080( )
90 A 900 1700 FA26090( ) 947. FH26090( ) 1452. FI26090( ) 2763.
100 A FA26100( ) FH26100( ) FI26100( )
3-pole, 600 Vac, 250 Vdc
15 A
275 600
FA36015
971.
FH36015
1446.
—— AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
20 A FA36020 FH36020 FI36020 3459.
25 A FA36025 FH36025 ——
30 A FA36030 FH36030 FI36030 3459.
35 A
400 850
FA36035
971.
FH36035
1446.
——
AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al
40 A FA36040 FH36040 FI36040 3459.
45 A FA36045 FH36045 ——
50 A FA36050 FH36050 FI36050 3459.
60 A
800 1450
FA36060 971. FH36060 1446. FI36060
3459.70 A FA36070 1163. FH36070 1632. FI36070
80 A FA36080 FH36080 FI36080
90 A 900 1700 FA36090 1163. FH36090 1632. FI36090 3459.
100 A FA36100 FH36100 FI36100
a1- and 2-pole circuit breaker catalog numbers are completed by adding the required connection letters as a suffix, See Digest page 9-24.
NOTE: As of January 1st, FI breakers will only fit on the wide side of I-Line panelboards.
Table 9.117: PowerPact™ Q-frame b— 225 A, Thermal-magnetic (240 Vac)
Ampere
Rating
AC Magnetic
Trip Settings "B" Interrupting "D" Interrupting "G" Interrupting "J" Interrupting
Hold Trip Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price
2-pole, 240 Vac c
70 A
1000 1800
QBA22070( )
600.
QDA22070( )
1202.
QGA22070( )
1593.
QJA22070( )
1992.80 A QBA22080( ) QDA22080( ) QGA22080( ) QJA22080( )
90 A QBA22090( ) QDA22090( ) QGA22090( ) QJA22090( )
100 A
1200 2400
QBA22100( )
600.
QDA22100( )
1202.
QGA22100( )
1593.
QJA22100( )
1992.
110 A QBA22110( ) QDA22110( ) QGA22110( ) QJA22110( )
125 A QBA22125( ) QDA22125( ) QGA22125( ) QJA22125( )
150 A QBA22150( ) QDA22150( ) QGA22150( ) QJA22150( )
175 A QBA22175( ) QDA22175( ) QGA22175( ) QJA22175( )
200 A QBA22200( ) QDA22200( ) QGA22200( ) QJA22200( )
225 A QBA22225( ) QDA22225( ) QGA22225( ) QJA22225( )
3-pole, 240 Vac d
70 A
1000 1800
QBA32070( )
1913.
QDA32070( )
2069.
QGA32070( )
2835.
QJA32070( )
3245.80 A QBA32080( ) QDA32080( ) QGA32080( ) QJA32080( )
90 A QBA32090( ) QDA32090( ) QGA32090( ) QJA32090( )
100 A
1200 2400
QBA32100( )
1913.
QDA32100( )
2069.
QGA32100( )
2835.
QJA32100( )
3245.
110 A QBA32110( ) QDA32110( ) QGA32110( ) QJA32110( )
125 A QBA32125( ) QDA32125( ) QGA32125( ) QJA32125( )
150 A QBA32150( ) QDA32150( ) QGA32150( ) QJA32150( )
175 A QBA32175( ) QDA32175( ) QGA32175( ) QJA32175( )
200 A QBA32200( ) QDA32200( ) QGA32200( ) QJA32200( )
225 A QBA32225( ) QDA32225( ) QGA32225( ) QJA32225( )
bReplacement lugs are not available on QB, QD, QG, or QJ circuit breakers. Lugs for QB, QD, QG, or QJ circuit breakers accept one #4 AWG–300 kcmil.
No accessories are available for PowerPact Q Frame breakers.
c2-pole QB, QD, QG, and QJ circuit breakers are completed by adding the required phasing numbers as indicated in the parentheses, See Digest page 9-24.
d3-pole QB, QD, QG, and QJ circuit breakers for ABC phasing are complete without additional phasing number. For CBA phasing, complete the catalog
number by inserting the number “6” in the parentheses.
Table 9.118: Interrupt Ratings (kA)
FA FH FI QB QD QG QJ e
240 V 25 25 (1P 35–100 A), 65 (1P 15–30 A, 2P, 3P) 200 10 25 65 100
480 V18 25 (2, 3P) ————
600 V14 18 (2, 3P) 100————
e3-pole QJ circuit breakers are rated at 208Y/120 Vac only.
F-frame accessories . . . . . . . . . starting on Supplemental Digest page 3-24
F-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-54
F-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-51
Q-frame accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-38
. . . . . . . . . . . . . . . . . . . . . . . . . . .starting on Supplemental Digest page 3-24
Q-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54
Q-frame optional lugs . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-29
DE2 Discount
Schedule
www.schneider-electric.us
9-26 © 2012 Schneider Electric
All Rights Reserved
9PANELBOARDS
Circuit Breakers H- and J-frame for I-Line™ Panelboards and Switchboards
Class 612
a2 pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix see Table 9.128.
a2 pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix see Table 9.128.
Table 9.119: H-frame 150 A Thermal-Magnetic UL Current-Limitinga Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unitb Suitable for Reverse
Connectionb
Current
Rating @
40o C
Fixed AC Magnetic
Trip Cat. No.c
Interrupting Rating (2nd Letter of Catalog Number)
Terminal
Wire Range
D G JaLa
$ Price
Hold Trip 80% Rated 80% Rated 80% Rated 80% Rated
H-frame, 150A 2P, 600 Vac 50/60 Hz, 250 Vdca
15 A 350 A 750 A H( )A26015( ) 899. 1338. 1589. 2364.
AL150HD
14–3/0 AWG
Al or Cu
20 A 350 A 750 A H( )A26020( ) 899. 1338. 1589. 2483.
25 A 350 A 750 A H( )A26025( ) 899. 1338. 1589. 2483.
30 A 350 A 750 A H( )A26030( ) 899. 1338. 1589. 2483.
35 A 400 A 850 A H( )A26035( ) 899. 1338. 1589. 2483.
40 A 400 A 850 A H( )A26040( ) 899. 1338. 1589. 2483.
45 A 400 A 850 A H( )A26045( ) 899. 1338. 1589. 2483.
50 A 400 A 850 A H( )A26050( ) 899. 1338. 1589. 2483.
60 A 800 A 1450 A H( )A26060( ) 899. 1338. 1589. 2483.
70 A 800 A 1450 A H( )A26070( ) 1088. 1559. 1824. 2681.
80 A 800 A 1450 A H( )A26080( ) 1088. 1559. 1824. 2681.
90 A 800 A 1450 A H( )A26090( ) 1088. 1559. 1824. 2681.
100 A 800 A 1700 A H( )A26100( ) 1088. 1559. 1824. 2681.
110 A 900 A 1700 A H( )A26110( ) 2195. 3212. 4671. 5699.
125 A 900 A 1700 A H( )A26125( ) 2195. 3212. 4671. 5699.
150 A 900 A 1700 A H( )A26150( ) 2195. 3212. 4671. 5699.
H-frame 150A 3P, 600 Vac 50/60 Hz, 250 Vdc
15 A 350 A 750 A H( )A36015 1124. 1575. 1988. 2993.
AL150HD
14–3/0 AWG
Al or Cu
20 A 350 A 750 A H( )A36020 1124. 1575. 1988. 2993.
25 A 350 A 750 A H( )A36025 1124. 1575. 1988. 2993.
30 A 350 A 750 A H( )A36030 1124. 1575. 1988. 2993.
35 A 400 A 850 A H( )A36035 1124. 1575. 1988. 2993.
40 A 400 A 850 A H( )A36040 1124. 1575. 1988. 2993.
45 A 400 A 850 A H( )A36045 1124. 1575. 1988. 2993.
50 A 400 A 850 A H( )A36050 1124. 1575. 1988. 2993.
60 A 800 A 1450 A H( )A36060 1124. 1575. 1988. 2993.
70 A 800 A 1450 A H( )A36070 1361. 1772. 2225. 3243.
80 A 800 A 1450 A H( )A36080 1361. 1772. 2225. 3243.
90 A 800 A 1450 A H( )A36090 1361. 1772. 2225. 3243.
100 A 800 A 1700 A H( )A36100 1361. 1772. 2225. 3243.
110 A 900 A 1700 A H( )A36110 2730. 3779. 5432. 6951.
125 A 900 A 1700 A H( )A36125 2730. 3779. 5432. 6951.
150 A 900 A 1700 A H( )A36150 2730. 3779. 5432. 6951.
Table 9.120: J-frame 250 A Thermal-Magnetic UL Current-Limitinga Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unitb Suitable for Reverse
Connectionb
Current
Rating @
40oC
Adjustable AC Magnetic
Trip Cat. No.c
Interrupting Rating (2nd Letter of Catalog Number)
Terminal
Wire Range
D G JaLaRa
$ Price
Low High 80% Rated 80% Rated 80% Rated 80% Rated 80% Rated
J-frame 250A 2P, 600 Vac 50/60 Hz, 250 Vdca
150 A 750 A 1500 A J( )A26150( ) 2283. 3372. 4904. 5985. —AL175JD
4–4/0 AWG Al or Cu
175 A 875 A 1750 A J( )A26175( ) 2283. 3372. 4904. 5985. —
200 A 1000 A 2000 A J( )A26200( ) 2283. 3372. 4904. 5985. —AL250JD
3/0 AWG–350 kcmil
Al or Cu
225 A 1125 A 2250 A J( )A26225( ) 2283. 3372. 4904. 5985. —
250 A 1250 A 2500 A J( )A26250( ) 3138. 4463. 6536. 7338. —
J-frame 250A 3P, 600 Vac 50/60 Hz, 250 Vdc
150 A 750 A 1500 A J( )A36150 2867. 3968. 5705. 7299. 9676. AL175JD
4–4/0 AWG Al or Cu
175 A 875 A 1750 A J( )A36175 2867. 3968. 5705. 7299. 9676.
200 A 1000 A 2000 A J( )A36200 2867. 3968. 5705. 7299. 9676. AL250JD
3/0 AWG–350 kcmil
Al or Cu
225 A 1125 A 2250 A J( )A36225 2867. 3968. 5705. 7299. 9676.
250 A 1250 A 2500 A J( )A36250 3936. 5252. 7599. 9173. 11729.
Table 9.121: H-frame 150 A and J-frame 250 A Electronic Trip UL Current-Limitinga Circuit Breakers
(600 Vac) With Factory Sealed Trip Unitb Suitable for Reverse Connection d
Electronic Trip Unit
Sensor
Rating Cat. No.c
Interrupting Rating (2nd Letter of Catalog Number)
Type Function Trip Unit
D G JaLaRa
Terminal
$ Price
80%
Rated
80%
Rated
80%
Rated
80%
Rated
80%
Rated
600 Vac, 50/60 Hz, 3P
Micrologic
Standard
LI 3.2g
60 A H( )A36060U31X 1316. 1743. 2224. 3173. 4171.
AL150HDe
100 A H( )A36100U31X 1569. 1962. 2382. 3490. 4591.
150 A H( )A36150U31X 2911. 3965. 5626. 7288. 9631.
250 A J( )A36250U31X 3120. 4226. 5970. 7715. 10102. AL250JDf
LSI 3.2Sg
60 A H( )A36060U33X 1512. 1939. 2420. 3370. 4393.
AL150HDe
100 A H( )A36100U33X 1765. 2159. 2578. 3686. 4813.
150 A H( )A36150U33X 3107. 4161. 5823. 7484. 9853.
250 A J( )A36250U33X 3398. 4505. 6249. 7994. 10420. AL250JDf
Micrologic
Ammeter LSI 5.2A
60 A H( )A36060U43X 2143. 2570. 3051. 4001. 5185.
AL150HDe
100 A H( )A36100U43X 2396. 2789. 3209. 4317. 5653.
150 A H( )A36150U43X 3738. 4792. 6453. 8115. 10836.
250 A J( )A36250U43X 4299. 5406. 7150. 8895. 11561. AL250JDf
Micrologic
Energy LSI 5.2E
60 A H( )A36060U53X 2523. 2950. 3431. 4380. 5883.
AL150HDe
100 A H( )A36100U53X 2776. 3169. 3589. 4697. 6333.
150 A H( )A36150U53X 4118. 5172. 6833. 8495. 11342.
250 A J( )A36250U53X 4840. 5947. 7691. 9436. 12413. AL250JDf
Micrologic
Ammeter LSIG 6.2A
60 A H( )A36060U44X 2902. 3330. 3811. 4760. 6423.
AL150HDe
100 A H( )A36100U44X 3156. 3549. 3969. 5077. 6873.
150 A H( )A36150U44X 4497. 5551. 7213. 8875. 11864.
250 A J( )A36250U44X 5381. 6487. 8231. 9976. 13157. AL250JDf
Micrologic
Energy LSIG 6.2E
60 A H( )A36060U54X 3282. 3709. 4190. 5140. 6963.
AL150HDe
100 A H( )A36100U54X 3535. 3929. 4349. 5456. 7413.
150 A H( )A36150U54X 4877. 5931. 7593. 9254. 12386.
250 A J( )A36250U54X 5921. 7028. 8772. 10517. 13900. AL250JDf
aCircuit breakers with J, L, and R interrupting ratings are UL certified as current limiting.
bSee Supplemental Digest pages 3-2 and 3-3 for circuit breakers with field-interchangeable trip units
cTo complete catalog number, replace the blank with the appropriate rating (D, G, J, L).
dFor applications requiring communications, see Digest page 7-49.
eAL150HD wire range is 14–3/0 AWG Al or Cu.
fAL250JD wire range is 3/0 AWG–350 kcmil Al or Cu. For smaller wire range (4–4/0 AWG Al or Cu), replace the lug’s wire binding screws with the larger binding screws provided.
g3P circuit breakers with this trip unit can be used for 2P applications.
DE2 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-27
J-Frame Mission Critical Circuit Breaker
L-Frame Mission Critical Circuit Breaker
Table 9.122: K-frame—250 A, Thermal-magnetic, Current Limiting (600 Vac)
Ampere
Rating
AC Magnetic Trip Settings Current Limiting Terminal
Wire Range
Low High Catalog Number $ Price
2-pole, 600 Vac, 250 Vdc a
110 A 550 1100 KI26110( ) 6633. AL250KA
one #4 AWG–
350 kcmil
Al or Cu
125 A 625 1250 KI26125( ) 6633.
150 A 750 1500 KI26150( ) 6633.
175 A 875 1750 KI26175( ) 6633.
200 A 1000 2000 KI26200( ) 6633. AL250KI
one #1/0 AWG–
350 kcmil Al or Cu
225 A 1125 2250 KI26225( ) 6633.
250 A 1250 2500 KI26250( ) 7704.
3-pole, 600 Vac, 250 Vdc
110 A 550 1100 KI36110 8375. AL250KA
one #4 AWG–
350 kcmil
Al or Cu
125 A 625 1250 KI36125 8375.
150 A 750 1500 KI36150 8375.
175 A 875 1750 KI36175 8375.
200 A 1000 2000 KI36200 8375. AL250KI
one #1/0 AWG–
350 kcmil Al or Cu
225 A 1125 2250 KI36225 8375.
250 A 1250 2500 KI36250 9267.
a2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See Digest page 9-24.
KI36250
2- and 3-pole
4.5 in (114 mm)
Mounting Height
Table 9.123: J-frame 250 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac) With Factory Sealted Trip Units Suitable for Reverse Connectiona
Electronic Trip
Unit Type
Trip
Function Trip Unit Continuous
Current
D Interrupting G Interrupting J Interrupting L Interrupting Terminal
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
Standard LI 3.2 W 250 JDA34250WU31X 3619. JGA34250WU31X 4857. JJA34250WU31X 6808. JLA34250WU31X 8759. AL250JDb
Standard LSI 3.2S-W 250 JDA34250WU33X 3931. JGA34250WU33X 5169. JJA34250WU33X 7119. JLA34250WU33X 9071. AL250JDb
High Perf. Ammerter LSI 5.2A-W 250 JDA34250WU43X 4939. JGA34250WU43X 6176. JJA34250WU43X 8127. JLA34250WU43X 10079. AL250JDb
High Perf. Energy LSI 5.2E-W 250 JDA34250WU53X 5544. JGA34250WU53X 6782. JJA34250WU53X 8732. JLA34250WU53X 10684. AL250JDb
High perf. Ammerter LSIG 6.2A-W 250 JDA34250WU44X 6148. JGA34250WU44X 7386. JJA34250WU44X 9336. JLA34250WU44X 11288. AL250JDb
High Perf. Energy LSIG 6.2E-W 250 JDA34250WU54X 6753. JGA34250WU54X 7991. JJA34250WU54X 9942. JLA34250WU54X 11893. AL250JDb
aStandard rated (80%). Not available in 100% rated.
bAL250JD terminal wire range is (1) 3/0 AWG–350 kcmil Al or Cu.
Table 9.124: L-frame 600 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac) With Factory Sealted Trip Units Suitable for Reverse Connectiona
Electronic Trip
Unit Type
Trip
Function Trip Unit Continuous
Current
D Interrupting G Interrupting J Interrupting L Interrupting Terminal
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
Standard LI 3.3 W
250 LDA34250WU31X 5991. LGA34250WU31X 6291. LJA34250WU31X 10299. LLA34250WU31X 11998. AL400L61K3b
400 LDA34400WU31X 5991. LGA34400WU31X 6291. LJA34400WU31X 10299. LLA34400WU31X 11998. AL600LF52K3c
600 LDA34600WU31X 8684. LGA34600WU31X 9126. LJA34600WU31X 12733. LLA34600WU31X 14263.
Standard LSI 3.3S-W
250 LDA34250WU33X 6656. LGA34250WU33X 6990. LJA34250WU33X 10999. LLA34250WU33X 12698. AL400L61K3b
400 LDA34400WU33X 6656. LGA34400WU33X 6990. LJA34400WU33X 10999. LLA34400WU33X 12698. AL600LF52K3c
600 LDA34600WU33X 9349. LGA34600WU33X 9826. LJA34600WU33X 13433. LLA34600WU33X 14962.
High Perf. Ammeter LSI 5.3A-W 400 LDA34400WU43X 7674. LGA34400WU43X 8062. LJA34400WU43X 12070. LLA34400WU43X 13769. AL600LF52K3c
600 LDA34600WU43X 10366. LGA34600WU43X 10896. LJA34600WU43X 14503. LLA34600WU43X 16033.
High Perf. Energy LSI 5.3E-W 400 LDA34400WU53X 8791. LGA34400WU53X 9238. LJA34400WU53X 13247. LLA34400WU53X 14946. AL600LF52K3c
600 LDA34600WU53X 11485. LGA34600WU53X 12074. LJA34600WU53X 15681. LLA34600WU53X 17210.
High Perf. Ammeter LSIG 6.3A-W 400 LDA34400WU44X 9911. LGA34400WU44X 10417. LJA34400WU44X 14426. LLA34400WU44X 16125. AL600LF52K3c
600 LDA34600WU44X 12604. LGA34600WU44X 13251. LJA34600WU44X 17139. LLA34600WU44X 18388.
High Perf. Energy LSIG 6.3E-W 400 LDA34400WU54X 11029. LGA34400WU54X 11594. LJA34400WU54X 15602. LLA34400WU54X 17301. AL600LF52K3c
600 LDA34600WU54X 13722. LGA34600WU54X 14429. LJA34600WU54X 18036. LLA34600WU54X 19566.
aStandard rated (80%). Not available in 100% rated.
bAL400L61K3 terminal wire range is (1) #2 AWG–500 kcmil Al or #2 AWG–600 kcmil Cu..
cAL600LF52K3 terminal wire range is (2) #3/0 AWG–500 kcmil Al or Cu.
Table 9.125: PowerPact™ H-, J-, and L-frame Automatic Molded Case Switches, 600 Vac
Circuit
Breaker Poles Ampere
Rating
G Withstand L Withstand R Withstand
Terminal Wire Range
Cat. No. $ Price Trip
Point Cat. No. $ Price Trip Point Cat. No. $ Price Trip Point
H-frame
J-frame
2a150 A HGA26000S15( ) 1349. 2250 A HLA26000S15 1590. 2250 A — — — — —
175 A JGA26000S17( ) 1827. 3125 A JLA26000S17 1980. 3125 A — — — — —
250 A JGA26000S25( ) 1827. 3125 A JLA26000S25 1980. 3125 A — — — — —
3150 A HGA36000S15 1799. 2250 A HLA36000S15 1988. 2250 A HRA36000S15 2295. 2250 A AL150HD 14 AWG–3/0 AWG Al/Cu
175 A JGA36000S17 2286. 3125 A JLA36000S17 2475. 3125 A JRA36000S17 2860. 3125 A AL175JD 4–4/0 AWG Al/Cu
250 A JGA36000S25 2286. 3125 A JLA36000S25 2475. 3125 A JRA36000S25 2860. 3125 A AL250JD 3/0 AWG–350 kcmil Al/Cu
L-frame 3 400 A LGA36000S40X 4572. 4800 A LLA36000S40X 4972. 4800 A LRA36000S40X 5688. 4800 A AL150HD AL600LS52K3
(2) 2/0 AWG–500 kcmil Al/Cu
600 A LGA36000S60X 5065. 6600A LLA36000S60X 5465. 6600 A LRA36000S60X 6220. 6600 A AL250JD
a2-pole circuit breaker catalog numbers are completed by adding the required phase connection number as a suffix, see Table 9.128.
Table 9.126: KI Interrupt Ratings (kA)
VKI
240 200
480 200
600 100
K-frame accessories . . . . . . . . . . starting on Supplemental Digest page 3-25
K-frame dimensions. . . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-33
K-frame optional lugs. . . . . . . . . . . . . . . . . . . Supplemental Digest page 3-28
H-, J-, and L-frame accessories . . . . . . . . . . . . .starting on Digest page 7-36
H-, J-, and L-frame dimensions. . . . . . . . . . . . . .starting on Digest page 7-54
H-, J-, and L-frame optional lugs. . . . . . . . . . . . . . . . . . . . . .Digest page 7-39
Table 9.127: Interrupt Ratings (kA)
D G J L
240 V 25 65 100 125
480 V 18 35 65 100
Table 9.128: Phase Options—Example HDA26150( )
Phase
Option
Number
Phase
Connection 2-pole 3-pole
1 AB HDA261501 —
2 AC HDA261502 —
3 BA HDA261503 —
4 BC HDA261504 —
5 CA HDA261505 —
6 CB HDA261506 —
Standard ABC — JDA34250WU31X
6 CBA — JDA34250WU31X6
Circuit Breakers K-, PowerPact H-, J-, L-frame for I-Line™ Panelboards and Switchboards
Class 825, 0612
DE2 Discount
Schedule
9-28 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
9PANELBOARDS
Circuit Breakers LA Mission Critical for I-Line™ Panelboards and Switchboards
Class 660, 665, 670, 830
LA Mission Critical Circuit Breakers
The LA High Magnetic Withstand MC Circuit Breakers are designed to trip at a higher magnetic trip level (18–20 times
handle rating) than typical molded case circuit breakers (MCCBs) (which trip at 5–10 times the handle rating). The high
magnetic withstand value of these LA circuit breakers allow the downstream branch circuit breaker to clear the fault.
L-frame acccessories. . . . . . . . . starting on Supplemental Digest page 3-24
L-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-54
L-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-53
LA/LH
2- and 3-pole
6 in (152 mm)
Mounting Height
LI
2- and 3-pole
7.5 in (190 mm)
Mounting Height
Table 9.129: L-frame—400 A, I-Line™ LA/LH MC High Magnetic Withstand Circuit Breaker For Mission Critical Loads
Ampere
Rating
AC Magnetic Level
Factory Set aStandard Interrupting High Interrupting Terminal
Hold Trip Cat. No. $ Price Cat. No. $ Price Cat. No. Wire Range
LA/LH MC Circuit Breaker, 3P, 480 Vac
200 A 3400 A 4000 A LA34200MC 5571. LH34200MC 8771.
AL250LAMC (1) 250–350 kcmil Al
(1) 3/0 AWG–350 kcmil Cu
225 A 3825 A 4500 A LA34225MC 5571. LH34225MC 8771.
250 A 4250 A 5000 A LA34250MC 5681. LH34250MC 8882.
400 A 6000 A 7200 A LA34400MC 6941. LH34400MC 10142. AL400LA (1) 1 AWG–600 kcmil Al or
(2) 1 AWG–250 kcmil Al
aAC magnetic setting tolerances are +0 -25% from maximum value shown.
Table 9.130: L-frame—400 A, Thermal-magnetic (600 Vac)
Ampere
Rating
AC Magnetic
Trip Settings Standard Interrupting High Interrupting Terminal
Wire
Range
Low High Catalog Number $ Price Catalog Number $ Price
2-pole, 600 Vac, 250 Vdc b
125 A 625 1250 LA26125( ) 4053. LH26125( ) 6762.
AL400LA
one #1 AWG–600 kcmil or
two #1 AWG–250 kcmil
AL or Cu
150 A 750 1500 LA26150( ) 4053. LH26150( ) 6762.
175 A 875 1750 LA26175( ) 4053. LH26175( ) 6762.
200 A 1000 2000 LA26200( ) 4053. LH26200( ) 6762.
225 A 1125 2250 LA26225( ) 4053. LH26225( ) 6762.
250 A 1250 2500 LA26250( ) 4053. LH26250( ) 6762.
300 A 1500 3000 LA26300( ) 4053. LH26300( ) 6762.
350 A 1750 3500 LA26350( ) 4053. LH26350( ) 6762.
400 A 2000 4000 LA26400( ) 4053. LH26400( ) 6762.
3-pole, 600 Vac, 250 Vdc
125 A 625 1250 LA36125 4944. LH36125 8145.
AL400LA
one #1 AWG–600 kcmil or
two #1 AWG–250 kcmil
AL or Cu
150 A 750 1500 LA36150 4944. LH36150 8145.
175 A 875 1750 LA36175 4944. LH36175 8145.
200 A 1000 2000 LA36200 4944. LH36200 8145.
225 A 1125 2250 LA36225 4944. LH36225 8145.
250 A 1250 2500 LA36250 4944. LH36250 8145.
300 A 1500 3000 LA36300 4944. LH36300 8145.
350 A 1750 3500 LA36350 4944. LH36350 8145.
400 A 2000 4000 LA36400 4944. LH36400 8145.
LC
2- and 3-pole
7.5 in (190 mm)
Mounting Height
Table 9.131: L-frame—600 A, Thermal-magnetic (600 Vac)c
Ampere
Rating
AC Magnetic Trip Settings Extra High Interrupting Current Limiting Terminal
Wire
Range
Low High Catalog
Number $ Price Catalog
Number $ Price
2-pole, 600 Vac b
300 A 1500
3200
LC26300( )
8312.
LI26300( )
9563.
AL600LI5
two #4/0 AWG–500 kcmil
AL or Cu
350 A 1750 LC26350( ) LI26350( )
400 A 2000 LC26400( ) LI26400( )
450 A 2250
4200
LC26450( )
8691.
LI26450( )
13949.500 A 2500 LC26500( ) LI26500( )
600 A 3000 LC26600( ) LI26600( )
3-pole, 600 Vac
300 A 1500
3200
LC36300
9234.
LI36300
10673.
AL600LI5
two #4/0 AWG–500 kcmil
AL or Cu
350 A 1750 LC36350 LI36350
400 A 2000 LC36400 LI36400
450 A 2250
4200
LC36450
9657.
LI36450
15498.500 A 2500 LC36500 LI36500
600 A 3000 LC36600 LI36600
b2-pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog number. See Digest page 9-24.
cType LC and LI circuit breakers are NOT recommended for use on single-motor branch circuits.
Table 9.132: Interrupt Ratings (kA)
LA LH LC LI
240 V 42 65 100 200
480 V 30 35 65 200
600 V 22 25 35 100
DE2 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-29
Circuit Breakers L- and PowerPact M-frame for I-Line™ Panelboards and Switchboards
Class 612, 661
P- and R-frame accessories . . . . . . . . . . . . . . . starting on Digest page 7-36
P- and R-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
P- and R-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39
Table 9.133: L-frame 600 A Circuit Breakers with Lugs and Factory-Sealed Electronic Trip Units Suitable for Reverse Connectiona
Electronic Trip Unit
Sensor
Rating
Catalog
Numberb
Interrupting Rating (2nd Letter of Catalog Number)
Terminal
D G J cL cR c
Type Function Trip
Unit
$ Price
80% 100% 80% 100% 80% 100% 80% 100% 80% 100%
600 Vac, 53/60 Hz, 3P
Micrologic
Standard LI 3.3d
250 A L( )A36250U31X 5122. 5943. 5376. 6240. 8773. 10214. 10213. 11899. 11745. 13745. AL400L61K3e
400 A
600 A
L( )A36400U31X
L( )A36600U31X
5122.
7404.
5943.
—
5376.
7779.
6240.
—
8773.
10836.
10214.
—
10213.
12132.
11899.
—
11745.
13952.
13745.
—AL600LF52K3f
Micrologic
Standard LSI 3.3Sd
250 A L( )A36250U33X 5686. 6506. 5969. 6833. 9366. 10808. 10806. 12493. 12427. 14449. AL400L61K3e
400 A
600 A
L( )A36400U33X
L( )A36600U33X
5686.
7968.
6506.
—
5969.
8372.
6833.
—
9366.
11429.
10808.
—
10806.
12725.
12493.
—
12427.
14634.
14449.
—
AL600LF52K3f
Micrologic
Ammeter LSI 5.3A 400 A
600 A
L( )A36400U43X
L( )A36600U43X
6548.
8830.
7368.
—
6877.
9279.
7740.
—
10274.
12336.
11715.
—
11714.
13632.
13400.
—
13471.
15677.
15523.
—
Micrologic
Energy LSI 5.3E 400 A
600 A
L( )A36400U53X
L( )A36600U53X
7495.
9778.
8316.
—
7874.
10277.
8738.
—
11271.
13334.
12713.
—
12711.
14630.
14398.
—
14618.
16825.
16705.
—
Micrologic
Ammeter LSIG 6.3A 400 A
600 A
L( )A36400U44X
L( )A36600U44X
8444.
10726.
9264.
—
8873.
11275.
9736.
—
12270.
14332.
13711.
—
13710.
15628.
15396.
—
15767.
17972.
17887.
—
Micrologic
Energy LSIG 6.3E 400 A
600 A
L( )A36400U54X
L( )A36600U54X
9392.
11674.
10212.
—
9870.
12273.
10734.
—
13267.
15329.
14709.
—
14707.
16626.
16394.
—
16913.
19120.
19069.
—
aSee Supplemental Digest page 3-4 for circuit breakers with field-interchangeable trip units.
bFor 100% rated circuit breakers (250 A and 400 A only), add a “C” in the 9th character place (for example, LRA36400CU31X).
cCircuit breakers with J, L, and R interrupting ratings are UL certified as current limiting.
d3P circuit breakers with this trip unit can be used for 2P applications.
eAL400L61K3 terminal wire ranges are (1) 2 AWG–600 kcmil Cu or (1) 2 AWG–500 kcmil Al.
fAL600LFS52K3 terminal wire range is (2) 3/0 –500 kcmil.
gFor applications requiring communications, see Digest page 7-43.
Interrupt Ratings (kA)
G J L h
240 V 65 100 125
480 V 35 65 100
600 V i18 25 25
hL interrupting rating is not
available in M-frame.
i600 V interrupt ratings
not available for D-frame.
Table 9.134: PowerPact M-frame: with ET1.0 Factory – sealed trip unit (not field adjustable)—800 A j
Ampere
Rating
Adjustable Instantaneous Trip Range kG Interrupting J Interrupting Terminal
Wire Range
Low High Catalog Number l$ Price Catalog Number l$ Price
2-pole, 600 Vac,
50/60 Hz
300 A 600 3000 MGA26300( )
6633.
MJA26300( )
8253. 3–3/0
through 500
kcmil
Al or Cu
350 A 700 3500 MGA26350( ) MJA26350( )
400 A 800 4000 MGA26400( ) MJA26400( )
450 A 900 4500 MGA26450( ) MJA26450( )
500 A 1000 5000 MGA26500( ) MJA26500( )
600 A 1200 6000 MGA26600( ) MJA26600( )
700 A 1400 7000 MGA26700( ) 8370. MJA26700( ) 10104.
800 A 1600 8000 MGA26800( ) MJA26800( )
3-pole, 600 Vac,
50/60 Hz
300 A 600 3000 MGA36300
8168.
MJA36300
9929. 3–3/0
through 500
kcmil
Al or Cu
350 A 700 3500 MGA36350 MJA36350
400 A 800 4000 MGA36400 MJA36400
450 A 900 4500 MGA36450 MJA36450
500 A 1000 5000 MGA36500 MJA36500
600 A 1200 6000 MGA36600 MJA36600
700 A 1400 7000 MGA36700 10608. MJA36700 12630.
800 A 1600 8000 MGA36800 MJA36800
jThe ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the long-time trip point setting. It is considered an electronic equivalent of a thermal-magnet circuit breaker.
kUL magnetic trip setting tolerances are ±10% from the nominal values shown.
lFill in parentheses with the following phase connection options: (2) for AC and (5) for CA.
L-frame accessories . . . . . . . . . .starting on Supplemental Digest page 3-24
L-frame dimensions. . . . . . . . . . . . . . . . . . . . . . starting on Digest page 7-54
L-frame optional lugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digest page 7-53
M-frame accessories. . . . . . . . . . . . . . . . . . . . . .starting on Digest page 7-36
M-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
M-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39
Table 9.135: Automatic Molded Case Switches—600 Vac, 50/60 Hz
Ampere
Rating
2-pole 3-pole Withstand Rating mTrip Point Amperes Terminal
Wire Range
Catalog Number n$ Price Catalog Number $ Price 240 Vac 480 Vac 600 Vac AC
600 A PJA26000S60( ) 6675. PJA36000S60 7263. 100 65 25 10000 3–3/0 through
500 kcmil Al or Cu
800 A PJA26000S80( ) 7347. PJA36000S80 7938. 100 65 25 10000
1000 A PJA26000S10( ) 8088. PJA36000S10 8676. 100 65 25 10000 4–3/0 through
500 kcmil Al or Cu
1200 A PJA26000S12( ) 10895. PJA36000S12 11766. 100 65 25 10000
mThe withstand rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a circuit breaker
with an equal ampere rating.
nFill in parentheses with the following phase connection options: (2) for AC or (5) for CA.
Table 9.136: PowerPact P- and R-frame Interrupt Ratings
Volt age P-frame Interrupt Rating R-frame Interrupt Rating
G J K L G J K L
240 Vac 65 kA 100 kA 65 kA 125 kA 65 kA 100 kA 65 kA 125 kA
480 Vac 35 kA 65 kA 50 kA 100 kA 35 kA 65 kA 65 kA 100 kA
600 Vac 18 kA 25 kA 50 kA 25 kA 18 kA 25 kA 65 kA 50 kA
DE2 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-30 © 2012 Schneider Electric
All Rights Reserved
Circuit Breakers PowerPact P- and R-frame for I-Line™ Panelboards and Switchboards
Class 612 / Refer to Catalog 0612CT0101
P- and R-frame accessories. . . . . . . . . . . . . . . . starting on Digest page 7-36
P- and R-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
P- and R-frame trip unit options . . . . . . . . . . . . . . . . . . . . . Digest page 7-44
P- and R-frame optional lugs . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-39
P- and R-frame alternate rating plugs . . . . . . . . . . . . . . . . . Digest page 7-45
Table 9.137: PowerPact P-frame 1200 A (600 Vac, 50/60 Hz) 3P Circuit Breaker with Electronic Trip Unit
Electronic Trip Unit Sensor
Rating Cat. No.ab
$ Price
Terminal
Wire Range
G Interrupting aJ Interrupting aK Interrupting aL Interrupting ac
Type Function Code 80%
Rated
100%
Rated b
80%
Rated
100%
Rated b
80%
Rated
100%
Rated b
80%
Rated
100%
Rated b
Basic Electronic
Trip Unit
(Not
Interchangeable)
Fixed long-time,
Adjustable
Instantaneous
ET1.0I
600 A P( )A36060 14603. —15480. —15480. —16359. —(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
800 A P( )A36080
1000 A P( )A36100 20003. —21207. —21207. —22410. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120
Micrologic
Interchangeable
Standard
Trip Unit
LI 3.0
250 A P( )A36025(C)U31A
15390. 22479. 16268. 23897. 16268. 23897. 17147. 25314.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U31A
600 A P( )A36060(C)U31A
800 A P( )A36080(C)U31A
1000 A P( )A36100U31A 20790. —21995. —21995. —23198. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U31A
LSI 5.0
250 A P( )A36025(C)U33A
15729. 22794. 16608. 24231. 16608. 24231. 17487. 25668.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U33A
600 A P( )A36060(C)U33A
800 A P( )A36080(C)U33A
1000 A P( )A36100U33A 21131. —22334. —22334. —23538. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U33A
Micrologic
Interchangeable
Ammeter
Trip Unit
LI 3.0A
250 A P( )A36025(C)U41A
16242. 23270. 17121. 24737. 17121. 24737. 17999. 26204.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U41A
600 A P( )A36060(C)U41A
800 A P( )A36080(C)U41A
1000 A P( )A36100U41A 21642. —22845. —22845. —24051. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U41A
LSI 5.0A
250 A P( )A36025(C)U43A
17739. 24659. 18618. 26214. 18618. 26214. 19497. 27770.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U43A
600 A P( )A36060(C)U43A
800 A P( )A36080(C)U43A
1000 A P( )A36100U43A 23141. —24345. —24345. —25548. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U43A
LSIG 6.0A
250 A P( )A36025(C)U44A
19607. 26393. 20486. 28058. 20486. 28058. 21365. 29721.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U44A
600 A P( )A36060(C)U44A
800 A P( )A36080(C)U44A
1000 A P( )A36100U44A 25008. —26211. —26211. —27416. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U44A
Micrologic
Interchangeable
Power
Trip Unit
LSI 5.0P
250 A P( )A36025(C)U63AE1
22151. 28754. 23030. 30566. 23030. 30566 23909. 32379.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U63AE1
600 A P( )A36060(C)U63AE1
800 A P( )A36080(C)U63AE1
1000 A P( )A36100U63AE1 27552. —28757. —28757. —29960. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U63AE1
LSIG 6.0P
250 A P( )A36025(C)U64AE1
23234. 29757. 24111. 31634. 24111. 31634. 24990. 33510.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U64AE1
600 A P( )A36060(C)U64AE1
800 A P( )A36080(C)U64AE1
1000 A P( )A36100U64AE1 28634. — 29838. —29838. —31041. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U64AE1
Micrologic
Interchangeable
Harmonic
Trip Unit
LSI 5.0H
250 A P( )A36025(C)U73AE1
26234. 32541. 27113. 34593. 27113. 34593. 27992. 36645
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U73AE1
600 A P( )A36060(C)U73AE1
800 A P( )A36080(C)U73AE1
1000 A P( )A36100U73AE1 31634. —32837. —32837. —34043. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U73AE1
LSIG 6.0H
250 A P( )A36025(C)U74AE1
27315. 33545. 28194. 35661. 28194. 35661. 29073. 37776.
(3) 3/0 AWG–500 kcmil
Al or Cu
AL800M23K
400 A P( )A36040(C)U74AE1
600 A P( )A36060(C)U74AE1
800 A P( )A36080(C)U74AE1
1000 A P( )A36100U74AE1 32717. —33921. —33921. —35124. —(4) 3/0 AWG–500 kcmil
Al or Cu
AL1200P24K
1200 A P( )A36120U74AE1
Table 9.138: PowerPact R-frame 1200 A (600 Vac, 50/60 Hz) 3P Circuit Breaker with Electronic Trip Unit
Electronic Trip Unit Sensor
Rating Cat. No.
$ Price Terminal
Wire
Range
G Interruptingac J Interruptingac K Interruptingac L Interruptingacd
Type Function Code 80%
Rated
100%
Rated
80%
Rated
100%
Rated
80%
Rated
100%
Rated
80%
Rated
100%
Rated
Basic Electronic Trip Unit
(Not Interchangeable)
Fixed Long-Time,
Adjustable Instantaneous ET1.01 1200 A R( )A36120 27080. —28777. —28777. —30533. —
AL1200R53K
(4) 3/0-600 kcmil
Al or Cu
Micrologic
Interchangeable Standard
Trip Unit
LI 3.0 1000 A R( )A36100CU31A —33945. —36111. —36111. —38418.
1200 A R( )A36120CU31A
LSI 5.0 1000 A R( )A36100CU33A —34401. —36599. —36599. —38934.
1200 A R( )A36120CU33A
Micrologic
Interchangeable Ammeter
Trip Unit
LI 3.0A 1000 A R( )A36100CU41A —35141. —37383. —37383. —39770.
1200 A R( )A36120CU41A
LSI 5.0A 1000 A R( )A36100CU43A —36581. —38916. —38916. —41400.
1200 A R( )A36120CU43A
LSI 6.0A 1000 A R( )A36100CU44A —38378. —40829. —40829. —43434.
1200 A R( )A36120CU44A
Micrologic
Interchangeable Power
Trip Unit
LSI 5.0P 1000 A R( )A36100CU63AE1 —40826. —43431. —43431. —46205.
1200 A R( )A36120CU63AE1
LSIG 6.0P 1000 A R( )A36100CU64AE1 —41867. —44540. —44540. —47382.
1200 A R( )A36120CU64AE1
Micrologic
Interchangeable Harmonic
Trip Unit
LSI 5.0H 1000 A R( )A36100CU73AE1 —44754. —47610. —47610. —50649.
1200 A R( )A36120CU73AE1
LSIG 6.0H 1000 A R( )A36100CU74AE1 —45795. —48719. —48719. —51827.
1200 A R( )A36120CU74AE1
aTo complete the catalog number, replace the blank ( ) with the appropriate interrupt rating (G, J, K, or L).
bFor 100% rated circuit breakers add a “C” in the 9th character place. For example, the catalog number for a 100% standard-type trip unit with LI trip functions at 250 A would be PGA36025CU31A.
cThe L interrupt rating is supplied in 480 V only. Change the 5th character (voltage rating) from a 6 (600 V) to a 4 (480 V); for example, PLA34025U31A.
dSee Table 9.136 on Digest page 9-29 for interrupt ratings.
DE2 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-31
I-Line™ Factory
Assembled Panelboards
600 Vac, 250 Vdc
Class 2110 / Refer To Catalog 2110CT9701
Table 9.139: Base $ Price—Main Lugs a
Panel Type Main Lugs
225 A 400 A 600 A 800 A 1200 A
HCN 1356. 1866. 2276. ——
HCM — 1866. 2276. 2512. —
HCP-SU — — 2990. 3600. —
HCP — — 2456. 3056. 3968.
HCR-U — — — — 4602.
aWhen required, add the $ Price of a solid neutral from Table 9.140.
Table 9.140: Standard Solid Neutral
Ampere Rating $ Price
100/225 A 294.
400 A 384.
600 A 544.
800 A 764.
1200 A 1366.
Table 9.141: Base $ Price—Main Circuit Breaker b
Main Circuit Breaker
Panel Type No.
Poles
100 A 150 A
FA FH FI cHD cHG cHJ cHL c
HCN 22100. 2100. 4642. 3360. 3860. 4540. 5550.
32418. 2958. 5864. 3770. 4210. 4890. 5900.
HCM 2— — —3360. 3860. 4540. 5550.
3— — —3770. 4210. 4890. 5900.
Panel Type No.
Poles
225 A 400 A 600 A
JD JG JJ JL KI cLD LG LJ LL LA LH LC cLI cLD LG LJ LL LC cLI cMG MJ
Electronic 100% Electronic 80%
HCN 23956. 4146. 7126. 7356. 8356. ————6132. 9126. ——————————
34440. 5550. 7466. 8676. 10148. ————7136. 10666 ——————————
HCM 23956. 4146. 7126. 7356. 8356. ————6132. 9126. ————————8880. 11260.
34440. 5550. 7466. 8676. 10148. ————7136. 10666. ————————10770. 13400.
HCP, HCP-SU 2—————
11865. 12470. 14795. 15940. ——10366. 11610. 15425. 16215. 19235. 20725. 11176. 16504. 8880. 11260.
3————— ——11888. 13354. 12678. 18090. 10770. 13400.
Panel Type No.
Poles
800 A d
MG MJ PL bPG cPJ cPL cPGC cPJC cPLC c
Micrologic™ 80% Micrologic 100%
HCN 2—————————
3—————————
HCM 211846. 14778. ———————
314302. 17456. ———————
HCP, HCP-SU 211846. 14778. 19346. 15830. 16830. 21090. 16542. 18510. 24250.
314302. 17456. 23416. 18312. 20280. 24540. 20144. 22300. 28220.
Panel Type No.
Poles
1200 A cde
PG PJ PL PG PJ PL RGC RJC RLC
Micrologic 80% Micrologic 100%
HCP, HCP-SU 222542. 24336. 26648. 22380. 24980. 27980. 24618. 24478. 32178.
324568. 26560. 29128. 28710. 31310. 35570. 31582. 34442. 40906.
HCR-U 222542. 24336. 26648. 22380. 24980. 27980. 24618. 24478. 32178.
324568. 26560. 29128. 28710. 31310. 35570. 31582. 34442. 40906.
bWhen required, add the $ Price of a solid neutral from Table 9.140.
cStandard construction back-fed main.
dPG, PJ, PL circuit breakers are available with both thermal-magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. The “C” suffix denotes a 100% rating.
eFor 1200 A frame thermal magnetic circut breaker with 600 kcmil lugs, select an R-frame Thermal Magnetic circuit breaker in the Product Selector.
Table 9.142: Electronic Trip Units for H-frame Circuit Breakers
Standard $ Price Ammeter $ Price Energy $ Price
LI (3.0) Standard ——
LSI (5.0) 549. 2550. 3485.
LSIG (6.0) f—4577. 5979.
Table 9.143: Electronic Trip Units for J-frame Circuit Breakers
Standard $ Price Ammeter $ Price Energy $ Price
LI (3.0) Standard ——
LSI (5.0) 785. 3643. 4978.
LSIG (6.0) f—6538. 8542.
Table 9.144: Electronic Trip Units (L-, P-, and R-frame Circuit Breakers)
$ Price
Standard Ammeter Energy Note: Power Harmonic
LI (3.0)Standard————
LSI (5.0) 1670. 4670. 7659. 21600. 32330.
LSIG (6.0) f—9340. 13777. 31000. 37000.
fWhen adding G, requires current transformers and a box extension and is available
factory assembled only.
Note: Energy trip unit available for L-frame circuit breakers only.
PowerPact circuit breakers come with a standard LI trip unit. Use the above $ Price adder
for increase in trip functionality. See Digest page 7-43 for L- frame trip unit descriptions.
See Digest page 7-44 for P- and R- frame trip unit descriptions.
Table 9.145: I-Line 200% Rated Neutral—Standard Terminal Configuration g
Panel
Type Ampacity Type
Branch Space Neutral Terminals Quantity and Size Type 1 Enclosure
In. mm Main Branch H W D
In. mm In. mm In. mm
HCM
600 A MLO 72 1829 (8) 750 kcmil
(35) 350 kcmil,
(9)#14-1/0, (17)#14-#4
91 2311 32 813 8.25 210
600 A (MG, MJ) M/B 72 1829 (8) 750 kcmil 91 2311 32 813 9.50 241
800 A MLO 72 1829 (8) 750 kcmil 91 2311 32 813 8.25 210
800 A (MG, MJ) M/B 72 1829 (8) 750 kcmil 91 2311 32 813 9.50 241
HCR-Uh1200A M/B, MLO 108 2743 (8) 750 kcmil (8) 600 kcmil, (15) 350 kcmil
(9) #14-1/0, (17)#14-#4 86 2184 44 1118 9.50 241
HCP
600A M/B, MLO 63 1600 (8) 750 kcmil (35) 350 kcmil,
(9)#14-1/0, (17)#14-#4 68 1727 42 1067 9.50 241
800A M/B, MLO 99 2515 (8) 750 kcmil (35) 350 kcmil,
(9)#14-1/0, (17)#14-#4 86 2184 42 1067 9.50 241
HCP-SUi800A M/B, MLO 54 1371 (8) 750 kcmil (8) 750 kcmil, (21) 350 kcmil,
(9) #14-1/0, (17) #14-#4 86 2184 26 660 9.5 241
gAvailable in Type 1 enclosure only; for pricing, see Digest page 9-34.
h6 in. enclosure extension is required for HCRU I-Line panelboard.
i9 in. enclosure extension is required for HCP-SU I-Line panelboard.
PE1 Discount
Schedule
www.schneider-electric.us
9-32 © 2012 Schneider Electric
All Rights Reserved
9PANELBOARDS
I-Line™ Factory
Assembled Panelboards
600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701
Table 9.146: Branch Circuit Breakers—Thermal Magnetic Circuit Breakers a
(See Digest pages 7-4 through 7-8 for interrupt rating, voltage ratings, Fed. Specs, etc.)
Circuit Breaker
Ampere Rating
Circuit
Breaker
3-pole e2-pole e1-pole e
240 V 480 Vac
250 Vdc 600 V Space
Only
H
(In.) 240 Vac 480 Vac
250 Vdc 600 Vac Space
Only
H
(In.) 120 V 277 V 277 Vac
125 Vdc
Space
Only
H
(In.)
15–60 A FA (FY-1P) 720. 882. 1006. 98. 4.5 520. 708. 786. 82. 3——270. c72. 1.5
70–100 A FA 832. 1142. b1218. 98. 4.5 632. 956. 964. 354. 384. 384. c72. 1.5
15–60 A FH 1100. —1442. 98. 4.5 1050. —1218. 98. 3——518. 72. 1.5
70–100 A 1300. —1940. 1250. —1620. ——650. 72. 1.5
15–60 A FJ d1300. 2080. —98. 31250. 1660. —98. 3—664. —72. 1.5
70–100 A 1500. 2470. —1450. 1980. ——832. —72. 1.5
20–100 A FI — — 4254. 98. 4.5 — — 3466. b98. 4.5 — — — — —
15–60 A
HD
——1350.
98. 4.5
——1150.
98. 3
—— — ——
70–100 A — — 1570. ——1370. —— — ——
110–150 A — — 2710. ——2370. —— — ——
15–60 A
HG
——1710.
98. 4.5
——1352.
98. 3
—— — ——
70–100 A — — 2198. ——1508. —— — ——
110–150 A — — 3310. ——3110. —— — ——
15–60 A
HJ
——2380.
98. 4.5
——2002.
98. 4.5
—— — ——
70–100 A — — 2700. ——2364. —— — ——
110–150 A — — 4500. ——3980. —— — ——
15–60 A
HL
——3910.
98. 4.5
——3250.
98. 4.5
—— — ——
70–100 A — — 4054. ——3402. —— — ——
110–150 A — — 5530. ——4600. —— — ——
70–225 A QB 1696. —— 98. 4.5 560. —— 82. 3— — — ——
70–225 A QD 2208. —— 98. 4.5 1300. b—— 82. 3— — — ——
70–225 A QG 2870. —— 98. 4.5 2800. —— 82. 3— — — ——
70–225 A QJ 3070. —— 98. 4.5 3000. —— 82. 3— — — ——
150–225 A JD ——2820. 98. 4.5 ——2600. 98. 4.5 —— — ——
250 A — — 3800. 3600. —3430. —— — ——
150–225 A JG ——3990. 98. 4.5 4600. —2790. 98. 4.5 —— — ——
250 A — — 4180. 3900. —3620. —— — ——
150–225 A JJ ——6110. 98. 4.5 4000. 5434. 5770. 98. 4.5 —— — ——
250 A — — 6500. 4300. 6672. 6450. —— — ——
150–225 A JL ——7320. 98. 4.5 4300. 5434. 6000. 98. 4.5 —— — ——
250 A — — 8900. 6672. 6800. —— — ——
150–225 A KI ——7972. 98. 4.5 ——6216. b98. 4.5 —— — ——
250 A — — 9268. ——7262. b—— — ——
300–400 A LA — — 4916. 252. 6——3980. 252. 6—— — ——
300–400 A LH — — 5312. ——4500. —— — ——
300–400 A LC 5460. —10156. 456. 7.5 4550. —8634. 456. 7.5 —— — ——
450–600 A — — 10422. ——8920. —— — ——
300–400 A LI ——11622. 456. 7.5 ——9878. b456. 7.5 —— — ——
450–600 A — — 15834. ——14248. b—— — ——
300–600 A MG ——8152. 662. 9——6322. 662. 9—— — ——
700–800 A — — 10600. ——8180. —— — ——
300–600 A MJ ——10126. 662. 9——8536. 662. 9—— — ——
700–800 A — — 13306. ——10944. —— — ——
600–800 A PL — 20360. —662. 9—16290. —662. 9— — — ——
600–1200 A PG — — 19966. 662. 9— —17940. 662. 9—— — ——
600–1200 A PJ /PK — — 21960. 662. 9— —19724. —— — ——
1000–1200 A PL — 24526. —662. 9—22046. —662. 9— — — ——
250–400 A
PLC (100%) e
—16940. —
662. 9
—13550. —
662. 9
—— — ——
450–600 A — 22620. ——18100. ——————
700–800 A — 24440. ——19560. ——————
1000–1200 A
RG (80%) e——24460.
662. 15
——24460.
662. 15
—— — ——
RJ (80%) e——26710. ——26710. —— — ——
RL (80%) e——32580. ——32580. —— — ——
aSee Digest pages 7-4 through 7-8 for additional dc ratings.
bac only.
cFA, 1P.
d480Y/277 Volt rated circuit breaker—Do not use on 480 Volt 3Ø3W Delta systems.
eSee Table 9.144 on Digest page 9-31 for P- and R frame Micrologic trip unit price adders.
PE1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 9-33
9PANELBOARDS
I-Line™ Factory
Assembled Panelboards
600 Vac, 250 Vdc
Class 2110 / Refer to Catalog 2110CT9701
Table 9.147: Branch Circuit Breakers—Electronic Trip Circuit Breakers a
(See Digest pages 7-4 through 7-8 for interrupt rating, voltage ratings, Fed. Specs, etc.)
Circuit Breaker
Ampere Rating
Circuit
Breaker
3-poled2-pole d1-pole d
240 V 480 Vac
250 Vdc 600 V Space
Only H240 Vac 480 Vac
250 Vdc 600 Vac Space
Only H120 V 277 V 277 Vac
125 Vdc
Space
Only H
15–60 A
HD (80%) b
—— 1790. 98. 4.5— —— ——— — — ——
35–100 A — — 2102. 98. 4.5— ————— — — ——
50–150 A — — 3756. 98. 4.5— ————— — — ——
70–250 A JD (80%) c—— 4013. 98. 4.5— ————— — — ——
15–60 A
HG (80%) b
—— 2110. 98. 4.5— ————— — — ——
35–100 A — — 2380. 98. 4.5— ————— — — ——
50–150 A — — 4848. 98. 4.5— —— ——— — — ——
70–250 A JG (80%) c—— 5082. 98. 4.5— ————— — — ——
15–60 A
HJ (80%) b
—— 2703. 98. 4.5— ————— — — ——
35–100 A — — 2898. 98. 4.5— —— ——— — — ——
50–150 A — — 6895. 98. 4.5— ————— — — ——
70–250 A JJ (80%) c—— 7231. 98. 4.5— ————— — — ——
15–60 A
HL (80%) b
—— 4027. 98. 4.5— ————— — — ——
35–100 A — — 4263. 98. 4.5— ————— — — ——
50–150 A — — 8943. 98. 4.5— —— ——— — — ——
70–250 A JL (80%) c—— 9381. 98. 4.5— ————— — — ——
70–250 A
LD (80%) d
—— 5378. 252. 6 — ————— — — ——
125–400 A — — 5378. 252. 6 — ————— — — ——
200–600 A — — 7775. 252. 6 — ————— — — ——
70–250 A
LG (80%) d
—— 5645. 252. 6 — ————— — — ——
125–400 A — — 5645. 252. 6 — ————— — — ——
200–600 A — — 8167. 252. 6 — ————— — — ——
70–250 A
LJ (80%) d
—— 9212. 252. 6 — ————— — — ——
125–400 A — — 9212. 252. 6 — —— ——— — — ——
200–600 A — — 11378. 252. 6 — ————— — — ——
70–250 A
LL (80%) d
——10724. 252. 6 — ————— — — ——
125–400 A — — 10724. 252. 6 — ————— — — ——
200–600 A — — 12738. 252. 6 — ————— — — ——
70–250 A LDC (100%) d—— 6991. 252. 6 — —— ——— — — ——
125–400 A — — 6991. 252. 6 — ————— — — ——
70–250 A LLC (100%) d——13941. 252. 6 — ————— — — ——
125–400 A — — 13941. 252. 6 — —— ——— — — ——
70–250 A LGC (100%) d—— 7338. 252. 6 — ————— — — ——
125–400 A — — 7338. 252. 6 — —— ——— — — ——
70–250 A LJC (100%) d——11975. 252. 6 — ————— — — ——
125–400 A — — 11975. 252. 6 — —— ——— — — ——
60–400 A DG (100%) e—5687. —252. 6— 4550. —252. 6— ————
600 A DG (80%) e—8954. —252. 6— 7163. —252. 6— ————
60–400 A DJ (100%) e—9118. —252. 6— 7295. —252. 6— ————
600 A DJ (80%) e—12385. —252. 6— 9908. —252. 6— ————
60–400 A DL (100%) e—10573. —252. 6— 8458. —252. 6— ————
600 A DL (80%) e—13839. —252. 6—11071. —252. 6— ————
250–400 A
PG (80%) d
—— 8900.
662. 9
——7120.
662. 9
—————
450–600 A — — 13310. ——10648. —————
700–800 A — — 14730. ——12402. —————
1000–1200 A — — 21240. ——16992. —————
250–400 A
PJ/PK (80%) d
——10400.
662. 9
——9240.
662. 9
—————
450–600 A — — 15570. ——12450. —————
700–800 A — — 17220. ——13780. —————
1000–1200 A — — 24850. ——19880. —————
250–400 A
PL (80%) d
—15400. —
662. 9
—12320. —
662. 9
—————
450–600 A — 20570. ——16450. — —————
700–800 A — 22220. ——17780. — —————
1000–1200 A — 29850. ——23880. — —————
250–400 A
PGC (100%) d
—— 9790.
662. 9
——7832.
662. 9
—————
450–600 A — — 14642. ——11714. —————
700–800 A — — 16200. ——13642. —————
250–400 A PJC/PKC (100%)
d
——11960.
662. 9
——9570.
662. 9
—————
450–600 A — — 17900. ——14330. —————
700–800 A — — 19800. ——15840. —————
250–400 A
PLC (100%)d
—16940. —
662. 9
—13550. —
662. 9
—————
450–600 A — 22620. ——18100. — —————
700–800 A — 24440. ——19560. — —————
1000–1200 A
RG (100%) d——29317.
662. 15
——29317.
662. 15
—————
RJ (100%) d——32159. ——32159. —————
RL (100%) d——39389. ——39389. —————
aSee Digest pages 7-4 through 7-8 for additional dc ratings.
bSee Table 9.142 on Digest page 9-31 for H-frame electronic trip unit price adders.
cSee Table 9.143 on Digest page 9-31 for J-frame electronic trip unit price adders.
dSee Table 9.144 on Digest page 9-31 for L-, P-, and R-frame electronic trip unit price adders.
eSee the Supplemental Digest for D-frame electronic trip unit price adders.
PE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-34 © 2012 Schneider Electric
All Rights Reserved
I-Line™ Factory Assembled Panelboards Common Feature Pricing
Class 2110 / Refer to Catalog 2110CT9701
Surgelogic™ SPD
Surgelogic SPD unit in I-Line plug-on
construction: An integrally mounted surge
protection solution that mounts on to an
I-Line Panelboard bus stack just like a
J-Frame circuit breaker. Requires 13.5 in.
of mounting height. Available as factory
assembled and merchandised. For SPD
unit pricing and information, see Digest
pages 6-3 and 6-44.
Table 9.148: QO Plug-On Branch Circuit Breakers
$ Price
Transition Charge per 6 QO one-pole spaces
(H=4.5 in. per 6 one-pole spaces) 328.
QO Branch circuit breakers See Digest page 7-10
Table 9.149: Sub-feed/Feed-through Lugs a
Ampere Rating $ Price
225 A 368.
400 A 600.
600 A 858.
800 A 1490.
1200 A 1890.
a2 or 3-pole Branch Mounted; SL Kit used for both SFL and TFL.
Table 9.150: Ground Bars
$ Price
Equipment Ground Bar 180.
Copper Ground Bar b148.
Insulated/Isolated Ground Bar $ Price Additional
Neutral Assembly
bAdd to equipment ground bar $ Price.
Table 9.151: Name Plates
$ Price
Standard white face/black letter laminated bakelite, 1 in. x 3.5 in., adhesive backed
or screw mountable with screws in a bag assembly ($ Price includes engraving) 78.
Table 9.152: Copper Bus Bars
Ampere Rating Type $ Price
225 A HCN, HCM 528.
400 A HCN, HCM, HCP 720.
600 A HCN 720.
600 A HCM, HCP, HCR-U 1274.
800-1200 A HCP, HCR-U 1274.
Table 9.153: Neutrals
Ampere Rating Type $ Price Adder
100–400 A Copper Neutral 868.
600 A Copper Neutral 894.
800 A Copper Neutral 1108.
1200 A Copper Neutral 1352.
Table 9.154: 200% Rated Neutrals
Ampere Rating Type $ Price Adder
225 A Aluminum 820.
400 A Aluminum 940.
600 A Aluminum 1340.
800 A Aluminum 1350.
1200 A Aluminum 2020.
225 A Copper 1210.
400 A Copper 1300.
600 A Copper 1980.
800 A Copper 2500.
1200 A Copper 2900.
Table 9.155: Metal Directory Frame
Metal Directory Frame $ Price Adder
Frame attached to trim (not available on four piece trim) 140.
Table 9.156: Door-in-Door Trim
Door-in-Door Trim $ Price Adder
Trim has piano hinge down one side.
Door opens by single latch; Entire trim opens by removing screws. 646.
Hinged Door-in-Door with Outer Door Lock Added 836.
Table 9.157: Weatherproof or Dusttight Cabinets—Type 3R, 5, 12
Weatherproof or Dusttight Cabinets $ Price Adder
Maximum 26 in. wide box 2156.
Maximum 28 in. wide box 3312.
Maximum 32 in. wide box 3312.
Maximum 42 in. wide box 3312.
Maximum 44 in. wide box 3312.
Table 9.158: Copper Mechanical Lugs
Ampere Rating Main Lug Interiors Main Circuit Breaker Interiors
$ Price per Pole
100/125 A 70. 70.
250 A 108. 108.
400 A 148. 148.
600 A 168. 168.
800 A 196. 196.
1200 A 236. 236.
Table 9.159: Copper Compression Lugs
Ampere Rating Main Lug Interiors Main Circuit Breaker Interiors
$ Price per Pole
100/125 A 70. 70.
250 A 108. 108.
400 A 148. 148.
600 A 168. 168.
800 A 316. 316.
1200 A 836. —
Table 9.160: Aluminum Compression Lugs VCEL
Ampere Rating Main Lug Interiors Main Circuit Breaker Interiors c
$ Price Per Pole
100 A 29.00 29.00
150 A N/A 29.00
250 A 29.00 49.00
400 A 45.00 74.00
600 A 59.00 131.00
800 A 100.00 —
1200 A 118.00 —
Note: Additional factory modifications. See Digest page 9-38.
cCompression lugs are not available on LC, LI, LE, LX, and LXI circuit breakers.
Table 9.161: Surgelogic SPD Options
Surgelogic SPD Options $ Price
Dry Contacts Standard
Remote Monitor 2588.
Note: Requires HCM interior minimum.
I-Line Plug-On Unit with
Surgelogic SPD
Table 9.162: Surgelogic Branch Mounted I-Line SPD—Model IMA
Volt age
Surge Current Rating kA
100 kA 120 kA 160 kA 200 kA 240 kA
HL FI HL FI HL FI HL FI HL FI
120/240 1P3W 18908. 20416. 20088. 21692. 23634. 25520. 29354. 30958. 34534. 36420.
208Y/120 3P4W 19750. 21260. 20984. 22588. 24688. 26574. 30740. 32342 36164. 38050.
240/120 3P4W 19750. 21260. 20984. 22588. 24688. 26574. 30740. 32342. 36164. 38050.
480Y/277 3P4W 20602. 22110. 21898. 23492. 25752. 27638. 32130. 33734. 37800. 39686.
600Y/347 3P4W — 23000. —24438. —28750. —35198. —41400.
PE1 Discount
Schedule
www.schneider-electric.us
© 2012 Schneider Electric
All Rights Reserved 9-35
9PANELBOARDS
QMB Fusible Branch
Switches
For QMB/QMJ Panelboards and Switchboards
Class 4620 / Refer to Catalog 4620CT9601
Table 9.163: QMB Branch Switch Units
Unit
Ampere
Rating
Unit
Height
(In.)
Catalog
Number $ Price
Class R Fuse Kits Electrical Interlock Kit Horsepower Ratingsi
No.
Kits
Req’d.
Catalog
Number $ Price Catalog
Number a$ Price
240 Vac 480 Vac 600 Vac
250 VdcStd. Max. Std. Max. Std. Max.
1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø
2-pole, 240 Vac
30 A-30 A 4.5 QMB221TW 608. 2HRK30 25.50 QMB300EK(1 or 2) 357. 1.5 3 3 7.5 ———————— 5
30 A-Blank 4.5 QMB221HWb425. 1———————— 5
60 A-60 A 4.5 QMB222TW 608. 1QMB36R 48.90 QMB300EK(1 or 2) 357. 3 7.5 10 15 ———————— 10
60 A-Blank 4.5 QMB222HWb425. ———————— 10
100 A-100 A 6 QMB223TW 990. 1QMB100R 95.00 QMB610EK(1 or 2) 357. 7.5151530———————— 20
100 A-Blank 6 QMB223HWb695. ———————— 20
200 A 9 QMB224W 1200. 1HRK1020 47.70 QMB200EK(1 or 2) 357. —251560———————— 40
400 A 15 QMB225W 3072. 1QMB4060R 111.00 — — ———————————— —
9QMB225WT3c2981. — — — — — ———————————— —
600 A Use 3-pole devices
for 2-pole application. —— ———————————— —
— ———————————— —
3-pole, 240 Vac
30 A-30 A 4.5 QMB321TW 827. 2HRK30 25.50
QMB300EK(1 or 2)
357. — 3 —7.5———————— —
30 A-Blank 4.5 QMB321HWb587. 1 — 3 —7.5———————— —
60 A-60 A 4.5 QMB322TW 827. 1QMB36R 48.90 357. —7.5—15———————— —
60 A-Blank 4.5 QMB322HWb587. —7.5—15———————— —
100 A-100 A 6 QMB323TW 1265. 1QMB100R 95.00 QMB610EK(1 or 2) 357. —15—30———————— —
100 A-Blank 6 QMB323HWb879. —15—30———————— —
200 A 9 QMB324W 1673. 1HRK1020 47.70 QMB200EK(1 or 2) 357. —25—60———————— —
400 A 15 QMB325W 4277. 1QMB4060R 111.00 — — —50—125———————— —
9QMB325WT3c4143. — — — — — —50—————————— —
600 A 15 QMB326W 6249. 1QMB4060R 111.00 — — —75—150———————— —
15 QMB326WT3c6249. — — — — — —75—————————— —
800 A 15 QMB327WT3c12140. — — — — — —75—————————— —
2-pole, 600 Vac, 250 Vdcd
30 A-30 A 4.5 QMB261TW 1050. 1QMB36R 48.90 QMB300EK(1 or 2) 357. 1.5 —3—357.5153
—10 —5
30 A-Blank 4.5 QMB261HWb702. —— ——
60 A-60 A 6 QMB262TW 1050. 1QMB60R 48.90
QMB610EK(1 or 2)
357. 3—10 —5 15203010—25 —10
60 A-Blank 6 QMB262HWb738. —— ——
100 A-100 A 7.5 QMB263TW 1536. 2HRK1020 47.70 357. 7.5 —15 —10 25 30 60 15 —40 —20
100 A-Blank 7.5 QMB263HWb1083. 1————
200 A 9 QMB264W 1791. 1HRK1020 47.70 QMB200EK(1 or 2) 357. 15 — — — 25 50 50 125 30 — 50 — 40
400 A Use 3-pole devices
for 2-pole application. — — ———————————— —
600 Ae
3-pole, 600 Vacd
30 A-30 A 4.5 QMB361TW 1241. 1QMB36R 48.90 QMB300EK(1 or 2) 357. —3—7.5—5—15—7.5—20 —
4.5 QMJ361T 1293. — — — ———————————20 5
30 A-Blank 4.5 QMB361HWb861. 1QMB36R 48.90 QMB300EK(1 or 2) 357. — 3—7.5 —5—15 —7.5 —20 —
60 A-60 A 6QMB362TW 1241. 1QMB60R 48.90 QMB610EK(1 or 2) 357. —7.5 —15 —15 —30 —15 —50 —
6QMJ362T 1293. — — — ———————————— 10
60 A-Blank 6 QMB362HWb861. 1QMB60R 48.90 QMB610EK(1 or 2) 357. — 7.5 —15 —15 —30 —15 —50 —
60 A-30 A 6QMB362T21W 1241. 1 ea. QMB60R and
QMB36R
48.90 QMB610EK(1 or 2) 357. —————————————
6 — ———————————— —
100 A-100 A 7.5 QMB363TW 1961. 2HRK1020 47.70 QMB610EK(1 or 2) 357. —15 —30 —25 —60 —30 —75 —
6QMJ363T 2013. — — — ———————————— 20
100 A-Blank 7.5 QMB363HWb1373. 1HRK1020 47.70 QMB610EK(1 or 2) 357. —15 —30 —25 —60 —30 —75 —
6QMJ363Hb1424. — — — ———————————— 20
100 A-30 A 7.5 QMB363T31W 1961. 1 ea. HRK1020 and
QMB36R
47.70 QMB610EK(1 or 2) 357. —————————————
7.5 48.90 ———————————— —
100 A-60 A 7.5 QMB363T32W 1961. 1 ea. HRK1020 and
QMB60R
47.70 QMB610EK(1 or 2) 357. —————————————
7.5 48.90 ———————————— —
200 A 9 QMB364W 2306. 1HRK1020 47.70 QMB200EK(1 or 2) 357. — 25 —60 —50 —125 —60 —150 —
200 A-200 A 7.5 QMJ364T 4712. —— —
QMB610EK(1 or 2) 357. —25 —60 —50 —125 —60 —150 40
200 A-Blank 7.5 QMJ364Hb2357. — — — ———————————— —
400 Af15 QMB365W 5445. 1QMB4060R 111.00 ———————100 —250 —125 —350 50
400 A 9 QMJ365 5561. — — — QMB200EK(1 or 2) 357. —50 —125 —100 —250 —125 —350 50
400 Af9QMB365WT6h5276. — — — — ———————————— —
600 Aef 15 QMB366W 6735. 1QMB4060R 111.00 — ——————150 —400 —250 —500 —
60 A0 15 QMJ366 6704. —— — —— —75—150————— —— —
800 Ag15 QMB367W 12140. — — ————————150 —400 —250 —500 —
a“1’’ indicates one normally open and one normally closed contact.
“2’’ indicates two normally open and two normally closed contacts.
bBlank units cannot be modified to accept a switch interior.
cUse 300 Vac Class T fuses only.
dClass J fuse provisions—to field modify switch, move load side fuse base to position indicated in switch. Not available on 100-30, 100-60, or 800 A switch units.
eTo adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB600T6, $ Price 194. (Use T6 fuses with standard horsepower ratings only).
f250 Vdc rating.
gTo adapt switch for 600 Vac Class T fuses, order kit Catalog Number QMB800T6, $ Price 467. (Use T6 fuses with standard horsepower ratings only).
hUse 600 Vac Class T fuses only.
iHorsepower rating applicable to 480Y/277 V system only.
Note: See the Supplemental Digest for merchandised motor starter units, QMB RTI panelboards, and replacement switches for Series 1–4 and D2 QMB panelboards.
Note: For series E1 and E2, QMJ switches may be used in 400 A–1200 A interiors in a NEMA 1 without door only. QMJ switches cannot be used in series E1 and E2, 225 A panelboards. QMJ
switches cannot be used in NEMA 1 with door or any NEMA 3R/12 enclosure.
PE1A Discount
Schedule
www.schneider-electric.us
9-36 © 2012 Schneider Electric
All Rights Reserved
9PANELBOARDS
QMB Factory Assembled Panelboards Fusible—600 Vac, 250 Vdc
Class 4620 / Refer to Catalog 4620CT9601
Table 9.164: Base $ Price
Main Lugs Main Switch aSolid Neutral
(Main Lugs and Main Switch)
Mains
Rating
(Amperes)
Maximum
Mounting
Space
(In.)
Base
$ Price
(2- or 3-pole)
Mains
Rating
(Amperes)
Maximum
Mounting
Space
(In.)
240 Vac 600 Vac
Base $ Price Base $ Price Ampere
Rating $ Price
2-pole 3-pole 2-pole 3-pole
———10051 2544. 3104. 3026. 3632. 100 A 294.
———20051 2544. 3104. 3026. 3632. 200 A 294.
225 60 1098. ——————225 A294.
400 60 1344. 400 45 4840. 6158. 5906. 7300. 400 A 384.
600 60 2066. 600 45 7298.c8758.c7968.de 9338.d600 A 556.
800 60 2550. 800b45 11098. 13704.c11128.d13724.d800 A 786.
1200 45 3550. ——————1200 A912.
aPricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches.
b800 A switch unit with provision for UL Class L fuses.
cSwitches for use with 300 V Class T fuses are also available at no additional cost.
dFor 600 Vac UL Class T fuse provision on main switch, add $ 321.00
e250 Vdc rating.
Table 9.165: Branch Switch $ Price f
Unit Ampere
Rating
Switch
Type
240 Vac 600 Vac
2-pole
$ Price
3-pole
$ Price
Space Only
$ Price
Unit Mounting Height
(In.)
2-pole
$ Price
3-pole
$ Price
Space Only
$ Price
Unit Mounting Height
(In.)
Twin Mounted Branch Switches g
30 A-Blank QMB 592. 784. 294. 4.5 852. 1012. 294. 4.5
60 A-Blank QMB 396. 6
100 A-Blank QMB 898. 1104. 392. 61276. 1592. 462. 7.5
QMJhm ——— — 396. 6
200 A-Blank QMJhm ——— — 1984. 2576. 462. 7.5
60 A-30 A QMB — — — — 1216. 1446. 396. 6
100 A-30 A QMB 1822. 2274. 396. 61822. 2274. 462. 7.5
100 A-60 A QMB
30 A-30 A QMB 826. 1120. 294. 4.5 1216.h1446. 294. 4.5
QMJhm ——— — 1216.
60 A-60 A QMB 826. 1120. 294. 4.5 1216.h1446. 396. 6
QMJhm ——— — 1216.
100 A-100 A QMB 1282. 1576. 396. 61822.j2274. 462. 7.5
QMJhm ——— — 1822. 396. 6
200 A-200 A — — — — 3970. 5154. 462. 7.5
Single Mounted Branch Switches
200 A QMB 1484. 2034. 580. 91984.h2576. 580. 9
400 A QMB 3204. 4562. 878. 15 4300.h5764.h878. 15
400 AiQMB 3040.i4360.i580. 94098.hi 5552.hi 580. 9
400 A QMJ hm ——— — 4098. 5552.
600 A QMB 4888.j6374.hj 878. 15 5264.hk 6962.hk
878. 15600 A QMJ hm ——— — 5264. 6962.
800 AlQMB 10682. 10682.j878. 15 10682.k10682.k
fPricing includes Class R or J Rejection Clips if requested at time of order. Class J fuses available only on 600 V switches.
g$ Price is per twin switch.
h250 Vdc rating.
iFor use with Class T fuses only. Use 300 V Class T fuses on 240 Vac max. systems and 600 V Class T fuses on 600 Vac max. systems.
jSwitches for use with 300 V Class T fuses are also available at no additional cost.
kFor 600 Vac UL Class T fuse provision on branch switch, add $ 307.00
l800 A switch unit with provision for UL Class L fuses.
mQMJ switches are available in NEMA 1 enclosures only.
Table 9.166: Accessories
Electrical Interlocks
Mains Ampere
Rating
Sub-feed Lugs n
for Main Lugs Interior n
Feed-through Lugs for Main
Switch Interior
Copper
Bus Bars
Number of Contacts Branch Switches
30–200 A $ Price
Normally Open Normally Closed
1
2
1
2472.
200 A — — 488.
225 A 282. — 488.
400 A 466. 872.o720.
600 A 856. 1268.o1148.
800 A 1150. 1512.o1372.
1200 A 1440. — 1428.
nNo extra box height required.
oBox height increases 6 in. Not available in Type 3R/5/12 construction.
Table 9.167: Circuit Breakers, Twin Mounted H-frame— $ Price Per Twin Unit
Circuit Breaker Ampere Rating
Unit Mounting Height
(In.)
$ Price—3-pole
Left Unit Right Unit 240 V 480 V 600 V Space Only
HD HG HD HG HD HG
15–150 A 15–150 A 6 2914. 3572. 3324. 3814. 3674. 4018. 396.
Note: See the Supplemental and Obsolescence Digest for merchandised motor starter units, QMB RTI panelboards, and replacement switches for Series 1-4 and D2 QMB panelboards.
Table 9.168: Circuit Breaker, Single Mounted JD-LA— $ Price Each
Circuit Breaker
Ampere Rating
Unit Mounting Height
(In.)
$ Price—3-pole
600 V Space Only
JD JG LA
150–250 A 6 3800. 5814. — 396.
225–400 A 7.5 — — 5664. 462.
Table 9.169: UL Listed Short Circuit Ratings
Starter Size Fusible Switch—600 V Max. (w/Class R or J Fuses) RMS Sym. Amps Thermal-magnetic Circuit Breaker 600 V Max. RMS Sym. Amps
0100,000 5,000
1100,000 5,000
2100,000 5,000
3100,000 5,000
PE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-37
QMB Factory Assembled
Panelboards
Common Features
Class 4620 / Refer to Catalog 4620CT9601
aAdd to Equipment Ground Bar $ Price.
b$ Price an additional Neutral Assembly from Table 9.164 on Digest page
9-36 for Al insulated ground bar or from Table 9.171 for Cu insulated
ground bar.
cStandard white face/black letter laminated bakelite, 1 in. x 3.5 in.
adhesive backed or screw mountable with screws in a bag assembly.
($ Price includes engraving.)
QMB Layout Information
To maximize the quantity of branch switches, use QMJ
switches from Digest page 9-36. Class J fuses are available in
time delay construction suitable for motor and transformer
loads.
Table 9.170: Ground Bar and Name Plates
Item $ Price
Equipment Ground Bar 180.
Copper Ground Bar 148. a
Insulated/Isolated Ground Bar ab
Name Plates 78. c
Table 9.171: Copper Neutral
$ Price
Copper Neutral
125–400 A 868.
600 A 894.
800 A 1108.
1200 A 1352.
Hinged Trim N/A
Weatherproof or Dusttight Cabinets—Type 3R, 5, 12; 800 A Max. 3054.
Mechanical Lugs 225 A–1200 A Standard
Table 9.172: Copper Mechanical Lugs—Main Switch Interiors
Copper Mechanical Lugs $ Price
200 A 108.
400 A 148.
600 A 168.
800 A 196.
Table 9.173: Copper Compression Lugs—Main Lug Interiors
Copper Compression Lugs $ Price
225 A 108.
400 A 148.
600 A 168.
800 A 316.
1200 A 836.
Table 9.174: Aluminum Compression Lugs VCEL—
Main Lug Interiors
Aluminum Compression Lugs VCEL $ Price
225 A 58.
400 A 90.
600 A 118.
800 A 200.
1200 A 236.
Table 9.175: Aluminum Compression Lugs VCEL—
Main or Branch Switches
Aluminum Compression Lugs VCEL $ Price
100 A #8–1/0 Al or Cu 58.
200 A #4–300 kcmil Al or Cu 98.
400 A 2/0–500 kcmil Al or Cu 128.
600 A 2/0–500 kcmil Al or Cu 246.
800 A 2/0–500 kcmil Al or Cu or 500 kcmil Cu or
500–750kcmil Al. 262.
Table 9.176: Copper Compression Lugs—Main Switch Interiors
Copper Compression Lugs $ Price
200 A 108.
400 A 148.
600 A 168.
800 A 196.
Table 9.177: Surgelogic™ SPD for QMB d
Surge
Current
Rating
kA
Volt age
120/240 V 208Y/120 V 240/120 Vac 480Y/277 Vac 600Y/347 Vac
1Ø3W 3Ø4W 3Ø4W
High Leg 3Ø4W 3Ø4W
100 — 14310. —15410. —
120 — 15654. —16754. —
160 — 18586. —19686. —
200 19196. 23596. 23596. 26896. 26896.
240 23760. 27440. 27440. 31460. 31460.
dRequires 9 in. of mounting height.
Table 9.178: SPD Options
Surgelogic SPD Options $ Price
Surge Counter Standard
Dry Contacts Standard
Remote Monitor 2588.
Maximum
Mounting
Space
for
Branch
Units
100 A twin QMB
6" H @ 240 Volt
60 A twin QMB
6" H @ 600 Volt
100 A twin QMJ
6" H @ 600 Volt
100 A twin QMB
7.5" H @ 600 Volt
200 A QMB
9" mounting height,
200 Amp twin QMJ
7.5" mounting height
38"
30/30 @ 240 or 600 V
or 60/60 @ 240 V
are 4.5" high
Wiring Gutter
400 A QMJ 9" H,
400 A Class T 9" H,
400, 600 or 800 A
QMB all require 15" H
Main Switch or
Main Lugs
PE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
9-38 © 2012 Schneider Electric
All Rights Reserved
Modifications for Factory Assembled Panelboards
Class 1640, 1670, 2110, 4620, 6650 / Refer to Catalog 2110CT9701, 1640CT0801, 4620CT9601
Main Circuit Breaker Without Overload Trip
(Automatic Molded Case Switch)
•(Not UL Listed)
$ Price as standard main circuit breaker, no $ Price Adder.
Shunt Trip Circuit Breakers
•See Digest page 7-35 for pricing.
Note: For molded case switch and automatic molded case switch short circuit current ratings,
See Digest page 7-33.
Special Features
For information on the following special features, please see the
Supplemental and Obsolescence Digest.
•Powerlogic™ metering k
•Customer equipment space (NQ and NF) k
•Increased box depth k
•Increased gutters–top, bottom, and sides k
•Non-standard paint k
•Welded base channel k
•Type 1 gasketed k
•Type 2 drip hood k
•Type 3R/4/4X/5/12 stainless steel enclosure k
•Type 4X fiberglass enclosure k
•Stainless steel trim front k
•Padlockable hasp k
•Special locks (Corbin, Yale, Best) k
•Equal height boxes k
•Common trim to cover two equal height boxes k
•Panelboard skirt—hides conduits feeding a panelboard k
•Panelboard wireway—for terminating conduit in wireway endwall k
•Keyed mechanical interlocking of two or more circuit breakers
(I-Line and QMB) k
•Motor operators (I-Line only)
•Panelboard interiors and special fronts to fit existing boxes
•A standard panelboard box has one blank endwall and one with
knockouts. Blank endwalls or knockouts in both endwalls are also
available k
kSupported by the Panelboard Product Selector.
Table 9.179: NQ and NF Lighting Contactors—Mechanically Held
(Furnish a one-line power and control voltage connection diagram.)
Ampacity
Mechanically Held
Type $ Price
Minimum Additional
Box Height Required a
H (In.)
Square D™ Brand PB b
30 A 2P PBM10B 3772. 18
60 A 2P PBP10B 4634. 18
75 A 2P PBN10B 4986. 18
100 A 2P PBQ10B 5072. 18
150 A 2P PBR10B 7156. 18
200 A 2P PBV10B 8692. 18
225 A 2P PBW10B 9830. 18
30 A 3P PBM11B 3740. 18
60 A 3P PBP11B 4754. 18
75 A 3P PBN11B 5628. 18
100 A 3P PBQ11B 6454. 18
150 A 3P PBR11B 8078. 18
200 A 3P PBV11B 8736. 18
225 A 3P PBW11B 10062. 18
ASCO Type 920 c
30 A 2P 9202030 4694. 18
60 A 2P 9202060 5954. 18
75 A 2P 9202075 5954. 18
100 A 2P 9202100 6194. 18
150 A 2P 9202150 9242. 18
200 A 2P 9202200 10882. 18
225 A 2P 9202225 11875. 18
30 A 3P 9203030 5436. 18
60 A 3P 9203060 7638. 18
75 A 3P 9203075 7638. 18
100 A 3P 9203100 9184. 18
150 A 3P 9203150 12998. 18
200 A 3P 9203200 14434. 18
225 A 3P 9203225 15750. 18
aNF panels require 18 in. of additional box height regardless of contactor ampacity or
manufacturer.
bIf two-wire control is required—Square D™ brand. Add 708. (No additional width or
depth required)
cIf two-wire control is required—ASCO type. Add 1412. (No additional width or
depth required)
Table 9.180: Current Density Rated Panelboard Bus and
Special Plating for Copper Bus
Ampacity
Copper Bus Special
Plating
$ List Price Adder d
Current Density Rated Bus
$ List Price Adder
Tin or Silver Plating 1000 A/in2 Cu 750 A/in2 Al
100 A 1240. 510. e
340. f125 A
225 A 1240. 610. e
250 A 456. f
400 A 2080. 830. 572. f
600 A 2080. 1050. f1080. fg
800 A 2080. 1490. 1244. g
1200 A 2080. 1710. 1432. gh
dStandard copper bus plating material
– NQ and NF: Silver plated bus/tin plated connectors
– I-Line and QMB: Tin.
eNQ available in 42 circuit only.
fNot available in NQ.
gHCN 600 A and all 800–1200 A I-Line interiors available with copper bus only.
h1200 A QMB with current density-rated bussing not available.
Table 9.181: NQ and NF Panelboard Split Bus Bars
Maximum
Ampacity
MLO
$ List Price Adder Maximum Number of
Pole Spaces Available Box Height
(ft.)
1-phase 3-phase Main Split
NQ Panelboards—125 A Maximum Lugs on Split Bus Section i
225 A 600. 900.
18 30
44
30 18
30
NF Panelboards—125 A Maximum Lugs on Split Bus Section i
250 A — 900.
18 30 56
30 18
30 62
iWhen greater than 125 A lugs are required on the split section of the bus, contact your
local Schneider Electric representative or distributor for the box height.
Table 9.182: I-Line™ Panelboard Split Bus Bars
Ampacity
MLO
$ Price Additional Mounting Height
Required On Split Bus Section j
2-pole 3-pole Split Bus
225 A 560. 662. 7.5 in.
400 A 662. 858. 9in.
600 A 786. 858. 12 in.
800 A 1094. 1238. 12 in.
1200 A 1320. 1442. 18 in.
Note: For applications with main circuit breaker panelboards, contact your local
Schneider Electric representative or distributor.
jFor I-Line panelboards, dimension includes height of “SL” sub-feed lug kit from Digest,
plus 3 in. from available branch mounting space.
PE1 Discount
Schedule
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-39
Panelboards NQ and NF Terminal Data
Class 1640, 1670, / Refer to Catalog 1670CT0701, 1640CT0801
Table 9.183: NQ Standard Aluminum Mechanical Lugs—Main Lugs
Panel Type Ampere Rating Lug Wire Range
NQ
100 A one #6-2/0 Al or Cu
225 A one #6-350 kcmil Al or Cu
400 A one 1/0-750 kcmil or
two 1/0-350 kcmil Al or Cu
600 A two 1/0-750 kcmil Al or Cu
Table 9.184: NQ Standard Aluminum Mechanical Lugs—Main Circuit Breaker
Panel Type Ampere Rating Circuit Breaker
Type Lug Wire Range a
NQ
100 A QOB one #4–#2/0 Al or Cu
FI one #14–#1/0 Al or Cu
150 A HD, HG, HJ, HL one #14–#3/0 Al or Cu
225 A QB, QD, QG, QJ one #4-300 kcmil Al or Cu
250 A
JD, JG, JJ, JL one #3/0–350 kcmil Al or Cu a
DJ one #2–600 Cu or #2–500 Al
KI one #1/0–350 kcmil Al or Cu
400 A LA, LH one #1–600 kcmil Al or Cu or
two #1–250 kcmil Al or Cu
600 A LC two #4/0-500 kcmil Al or Cu
aThe lug range shown is for the highest amperage of the circuit breaker frame shown in the table.
Table 9.185: NF Standard Mechanical Lugs—Main Lugs
Panel Type Ampere Rating Lug Wire Range
NF
125 A one #6–2/0 Al or Cu
250 A one #6–350 kcmil Al or Cu
400 A one #1/0–750 kcmil or two #1/0–350 kcmil Al or Cu
600 A two #1/0–600 kcmil Al or Cu
800 A three #4/0–500 kcmil Al or Cu
Table 9.186: NF Standard Mechanical Lugs—Main Circuit Breaker
Panel Type Ampere Rating Circuit Breaker Type Lug Wire Range b
NF
125 A ED, EG, EJ one #14–#2/0 Al or Cu
100 A FI one #14–#1/0 Cu or one #12–#1/0 Al
150 A HD, HG, HJ, HL one #14–#3/0 Al or Cu
250 A
JD, JG, JJ, JL one #3/0–350 kcmil Al or Cu b
DJ one #2–600 Cu or #2–500 Al
KI one #1/0–350 kcmil Al or Cu
400 A LA, LH one #1–600 kcmil or two #1–250 kcmil Al or Cu
600 A LC, LI, LE, LX, LXI two #4/0–500 kcmil Al or Cu
bThe lug range shown is for the highest amperage of the circuit breaker frame shown in the table.
9-40 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
9PANELBOARDS
I-Line™ and QMB Terminal Data
Class 2110, 4620 / Refer to Catalog 2110CT9701, 4620CT9601
a(#) = Number of conductors per phase.
bUse only 90 oC insulated conductors based on an ampacity of 75 oC conductors.
Table 9.187: Standard Mechanical Lugs—Main Lugs
Panel
Type
Ampere
Rating Lug Wire Range aWire Range
Wire Bending Space per NEC Table 373-6 a
I-Line
100 A — —
225 A one #6–300 kcmil Al or Cu one #6–300 kcmil Al or Cu
400 A two #2–600 kcmil Al or Cu one #2–600 kcmil Al or Cu
600 A two #2–600 kcmil Al or Cu two #2–500 kcmil Al or Cu
800 A (4) 3/0–750 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu
1200 A (4) 3/0–750 kcmil Al or Cu (4) 3/0–500 kcmil Al or Cu
Table 9.188: Standard Mechanical Lugs—Main Circuit Breaker
Panel
Type
Ampere
Rating
Circuit Breaker
Type Lug Wire Range aWire Range
Wire Bending Space per NEC Table 373-6 a
I-Line
100 A FA, FH, FI one #14-1/0 Al or Cu one #14-1/0 Al or Cu
150 A HD, HG, HJ, HL one #14-3/0 Al or Cu one #14-3/0 Al or Cu
225 A KI one #4-300 kcmil Al or Cu one #4-300 kcmil Al or Cu
250 A JD, JG, JJ, JL one #1/0-#4/0 Al or Cu one #1/0-300 kcmil Al or Cu
LX, LXI, LE two #1-350 kcmil Al or Cu two #1-350 kcmil Al or Cu
400 A LA, LH one #1-600 or two #1-250 kcmil Al or Cu one #1-600 kcmil Al or Cu
600 A LC, LI, LX, LXI, LE two 4/0-500kcmil Al or Cu two 4/0-500kcmil Al or Cu
800 A MG, MJ, PG, PJ, PL three 3/0-500 kcmil Al or Cu three 3/0-500 kcmil Al or Cu
1200 A PG, PJ, PL, RGC, RJC, RLC four 3/0-500 kcmil Al or Cu four 3/0-500 kcmil Al or Cu
Table 9.189: Standard Mechanical Lugs—Main Lugs
Panel
Type
Mains
Ampere
Rating
Lug Wire Range aWire Range
Wire Bending Space per NEC Table 373-6 a
QMB
225 A one #6–300 kcmil Al or Cu one #6–300 kcmil Al or Cu
400 A one #6–300 kcmil Al or Cu and,
one 3/0–750 kcmil Al or Cu
one #6–300 kcmil Al or Cu and,
one 3/0–750 kcmil Al or Cu
600 A two 3/0–500 kcmil Al or Cu two 3/0–500 kcmil Al or Cu
800 A (4) 3/0–750 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu or
two 3/0–750 kcmil Al or Cu
1200 A (4) 3/0–750 kcmil Al or Cu (4) 3/0–500 kcmil Al or Cu or
(4) 3/0–750 kcmil Al or Cu
1600 A VCEL compression lugs Standard.
Table 9.190: Standard Mechanical Lugs—Main Switch
Panel
Type
Mains
Ampere
Rating
Lug Wire Range aWire Range
Wire Bending Space per NEC Table 373-6 a
QMB
200 A #4–300 kcmil Al or Cu one #4–300 kcmil Al or Cu
400 A 3/0–600 kcmil Al or Cu two 3/0–600 kcmil Al or Cu
600 A 3/0–600 kcmil Al or Cu two 3/0–600 kcmil Al or Cu
800 A 3/0–600 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu
Table 9.191: Standard Mechanical Lugs—QMB Branch Switch Units
Panel
Type
Switch
Ampere
Rating
Lug Wire Range aWire Range
Wire Bending Space per NEC Table 373-6 a
QMB
30 A one #14–#2 Al or Cu one #14–#2 Al or Cu
60 A one #14–#2 Al or Cu one #14–#2 Al or Cu
100 A one #14–1/0 Al or Cu one #14–1/0 Al or Cu
200 A one #4–300 kcmil Al or Cu one #4–300 kcmil Al or Cu
400 A two 3/0–600 kcmil Al or Cu two 3/0–500 kcmil Al or Cu
600 A two 3/0–600 kcmil Al or Cu two 3/0–500 kcmil Al or Cu
800 A (3) 3/0–600 kcmil Al or Cu (3) 3/0–500 kcmil Al or Cu
Table 9.192: Standard Mechanical Lugs—QMJ Branch Switch Units b
Panel
Type
Switch
Ampere
Rating
Lug Wire Range aWire Range
Wire Bending Space per NEC Table 373-6 a
QMJ
30 A one #14–#2 Al or Cu one #14–#2 Al or Cu
60 A one #14–#2 Al or Cu one #14–#2 Al or Cu
100 A one #14–1/0 Al or Cu one #14–1/0 Al or Cu
200 A one #6–300 kcmil Al or Cu one #6–300 kcmil Al or Cu
400 A one 1/0–750 kcmil Al or Cu one 1/0–750 kcmil Al or Cu
400 A two 1/0–300 kcmil Al or Cu two 1/0–300 kcmil Al or Cu
600 A two 3/0–600 kcmil Al or Cu two 3/0–600 kcmil Al or Cu
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-41
I-Line™ Combo
Panelboard
Combination Panelboards
Table 9.193: Interior Boxes and Fronts — Includes Solid Neutral
I-Line
Mounting
Space
Part Number Panelboard
Ampacity
List
$ Price
Single/
Duplex
Lighting
Section
Type
Lighting
Section
Amperage
Lighting
Section
Circuits
Busing Ground Bar Box 4 Piece Trim
Without Door Trim with Door
NEMA 3R/5/12
(Includes
Fromnt)
18 CP18864N3Q2C 400 10334.00 S NQ 225 30 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18864N3Q2 400 7650.00 S NQ 225 30 Al PK32DGTA HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18864N4Q2C 400 10729.00 S NQ 225 42 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18864N4Q2 400 8045.00 S NQ 225 42 Al PK32DGTA HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18864N3F2C 400 17549.00 S NF 250 30 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18864N3F2 400 14749.00 S NF 250 30 Al PK32DGTA HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18864N4F2C 400 18147.00 S NF 250 42 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18864N4F2 400 15388.00 S NF 250 42 Al PK32DGTA HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18866N3Q4C 600 15032.00 S NQ 400 30 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18866N4Q4C 600 15428.00 S NQ 400 42 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18866N3F4C 600 21270.00 S NF 400 30 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
18 CP18866N4F4C 600 21863.00 S NF 400 42 Cu PK32DGTACU HC2686DB HC2686T( )4P HC2686T( )HR HC2686WP
22.5 CP23734N3Q2C 400 10686.00 S NQ 225 30 Cu PK32DGTACU HC3273DB9 HCM73T( )V HCM73T( )VD N/A
22.5 CP23734N3Q2 400 7942.00 S NQ 225 30 AL PK32DGTA HC3273DB9 HCM73T( )V HCM73T( )VD N/A
22.5 CP23734N3F2C 400 18065.00 S NF 250 30 Cu PK32DGTACU HC3273DB9 HCM73T( )V HCM73T( )VD N/A
22.5 CP23734N3F2 400 15249.00 S NF 250 30 AL PK32DGTA HC3273DB9 HCM73T( )V HCM73T( )VD N/A
22.5 CP23736N3Q4C 600 16159.00 S NQ 400 42 Cu PK32DGTACU HC3273DB9 HCM73T( )V HCM73T( )VD N/A
22.5 CP23736N3F4C 600 22539.00 S NF 400 42 Cu PK32DGTA HC3273DB9 HCM73T( )V HCM73T( )VD N/A
22.5 CP23914N4Q2C 400 11091.00 S NQ 225 42 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23914N4Q2 400 8346.00 S NQ 225 42 Al PK32DGTA HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23914N5Q2C 400 11604.00 S NQ 225 54 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23914N5Q2 400 8797.00 S NQ 225 54 Al PK32DGTA HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23914N4F2C 400 18672.00 S NF 250 42 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23914N4F2 400 15855.00 S NF 250 42 Al PK32DGTA HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23914N5F2C 400 19341.00 S NF 250 54 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23914N5F2 400 16508.00 S NF 250 54 Al PK32DGTA HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23916N4Q4C 600 16563.00 S NQ 400 42 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23916N5Q4C 600 17076.00 S NQ 400 54 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23916N4F4C 600 23145.00 S NF 400 42 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23916N5F4C 600 23814.00 S NF 400 54 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23916N44Q4C 600 26032.00 D NQ 400 42/42 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
22.5 CP23916N53Q4C 600 26141.00 D NQ 400 54/30 Cu PK32DGTACU HC3291DB9 HCM91T( )V HCM91T( )VD N/A
31.5 CP32866N44Q4C 600 26066.00 D NQ 400 42/42 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32866N53Q4C 600 26170.00 D NQ 400 54/30 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32866N4BQ4C 600 18362.00 D NQ 400 42/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32866N44F4C 600 38703.00 D NF 400 42/42 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32866N53F4C 600 38763.00 D NF 400 54/30 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32866N4BF4C 600 24681.00 D NF 400 42/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N44Q6C 800 36447.00 D NQ 600 42/42 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N53Q6C 800 36552.00 D NQ 600 54/30 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N3BQ6C 800 23026.00 D NQ 600 30/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N4BQ6C 800 23415.00 D NQ 600 42/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N5BQ6C 800 23300.00 D NQ 600 54/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N44F6C 800 38744.00 D NF 600 42/42 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N53F6C 800 38805.00 D NF 600 54/30 Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N3BF6C 800 23981.00 D NF 600 30/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N4BF6C 800 24563.00 D NF 600 42/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
31.5 CP32868N5BF6C 800 24599.00 D NF 600 54/O Cu PK32DGTACU HC4486DB HCR86T( ) HCR86T( )D HC4486WP
Table 9.194: RTI Cabled Lighting Section Kit for I-Line Combo Panelboard
Part Number Description MLO Panelboard
Ampacity
List
$ Price
Lighting
Section
Type
Lighting
Section
Circuits
NFICRT418L1C NF Lighting Section Kit 125 1528.00 NF 18
NFICRT442L2C NF Lighting Section Kit 250 1763.00 NF 42
NFICRT442L4C NF Lighting Section Kit 400 2353.00 NF 42
NFICRT442L6C NF Lighting Section Kit 600 2008.00 NF 42
NQICRT418L1C NQ Lighting Section Kit 100 1564.00 NQ 18
NQICRT442L2C NQ Lighting Section Kit 225 1373.00 NQ 42
NQICRT442L4C NQ Lighting Section Kit 400 2156.00 NQ 42
NQICRT442L6C NQ Lighting Section Kit 600 2332.00 NQ 42
NQICRT418C1C Contactor with 18 Circuit NQ Lighting Section Kit 100 1225.00 NQ 18
NFICRT418C1C Contactor with 18 Circuit NF Lighting Section Kit 125 1440.00 NF 18
www.schneider-electric.us
9PANELBOARDS
9-42 © 2012 Schneider Electric
All Rights Reserved
Series Ratings NQ Panelboards
Class 1640
This page contains UL Tested and Certified series combination ratings for
panelboards. These ratings apply to either an integral main located in the
same enclosure or a remote main located in a separate enclosure.
aFor shown circuit breakers rated less than this maximum voltage, the indicated short
circuit current rating also applies, but at the voltage rating of the circuit breaker
bShort circuit tests are conducted at 100–105% of the maximum rated voltage of the
panelboard.
cSuffixes HID, and SWD may also be applied to the applicable branch circuit breakers
shown above. Suffix SWN may not be applied in combination with LC main breakers.
dWhere QO (B) circuit breakers are shown above, QO (B) H, QO (B) VH, and QOH (B)
circuit breakers may also be used.
eWhere QO (B) GFI circuit breakers are shown above, QO (B) EPD and/or QO (B) EPE
circuit breakers may also be used. QO–EPE only comes in 3 pole construction.
fWhere QO (B) AFI circuit breakers are shown above, QO (B) CAFI circuit breakers may
also be used.
gTo achieve selective coordination, the rating of the DJ main circuit breaker must be at
least two times greater than the ampere rating of any branch circuit breaker.
hFor complete series ratings for Delta Systems please reference NQ/NQM Panelboards
Information Manual 80043–712–06.
Table 9.195: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Maximum
System
Voltage
AC ab
Maximum
Short
Circuit
Current
Rating
Square D™ Brand
Integral or Remote
Main Circuit Breakers
and Remote Main
Fuses
Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef
Type 1 Pole 2 Pole 3 Pole
120/240
1P/3W
22,000 MG QO (B) 15–30 A — —
25,000 LD, HD, JD
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A —
QO (B) PL 15–30 A 15–60 A —
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
65,000
HG, JG
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A —
QO (B) PL 15–30 A 15–60 A —
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LG
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A —
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LJ QO (B) GFI 15–30 A 40–60 A —
QO (B) EPD 15–30 A 40–60 A —
100,000
HJ, JJ
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A —
QO (B) PL 15–30 A 15–60 A —
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LJ
QO (B) 15–70 A 15–125 A —
QO(B) VH 15–70 A 15–125 A —
QO (B) H — 15–100 A —
QO (B) GFI — 15–30 A —
QO (B) EPD — 15–60 A —
QO(B) AFI 15–20 A — —
QO(B) CAFI 15–20 A — —
DJ 400 A
QO (B) 15–70 A 15–125 A —
QO (B) VH — 150 A —
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
QJ
QO (B) 15–70 A 15–125 A —
QO (B) AS 15–30 A 15–30 A —
QO (B) VH — 150 A —
QO (B) PL 15–30 A 15–60 A —
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
125,000 HL, JL
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A —
QO (B) PL 15–30 A 15–60 A —
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
208Y/120
3P/4W
240/120 V
3P/4W
18,000
LA/LH (L) 34200MC
QO (B) 15–30 A 15–30 A 15–30 A
LA/LH (L) 34225MC
LA/LH (L) 34250MC
LA/LH (L) 34400MC
25,000 LD
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–30 A 15–125 A 15–150 A
QO (B) GFI 15–30 A 15–60 A 15–30 A
QO (B) EPD 15–30 A 15–60 A 15–30 A
QO (B) EPE — — 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
30,000
DJ–W 150 A MC
QO (B) 15–70 A 15–100 A —
QO (B) VH — 15–125 A 15–150 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
DJ–W 250 A MC
QO (B) 15–70 A 15–100 A —
QO (B) VH — — 15–150 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
DJ–W 600 A MC
QO (B) 15–70 A 15–100 A —
QO (B) VH — — 15–150 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
208Y/120
3P/4W
240/120 V
3P/4W
65,000
LG
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A 15–150 A
QO (B) H — 15–100 A —
QO (B) GFI 15–30 A 15–60 A 15–30 A
QO (B) EPD 15–30 A 15–60 A 15–30 A
QO (B) EPE — — 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LJ
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A 15–150 A
QO (B) H — 15–100 A —
QO (B) GFI 15–30 A 15–60 A 15–30 A
QO (B) EPD 15–30 A 15–60 A 15–30 A
QO (B) EPE — — 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LL
QO (B) GFI — — 15–30 A
QO (B) EPD — — 15–30 A
QO (B) EPE — — 15–30 A
100,000
DJ 400 A
QO (B) 15–70 A 15–125 A —
QO (B) VH — — 15–150 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
QJ
QO (B) 15–70 A 15–125 A 15–30 A
QO (B) VH — — 15–150 A
QO (B) PL 15–30 A 15–60 A 15–30 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) EPE 15–30 A 15–60 A 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LJ
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A 15–150 A
QO (B) H — 15–100 A —
QO (B) GFI — 15–30 A —
QO (B) EPD — 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
240/120 V
3P/4W 22,000 QO (B) VH
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) EPE — — 15–50 A
QO (B) PL 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
240/120 V
3P/4W 25,000
QD
QO (B) 15–70 A 15–125 A 15–30 A
QO (B) VH — — 35–150 A
QO (B) PL 15–30 A 15–60 A 15–30 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) EPE — — 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
ED, FD
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
KD
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) AS 15–30 A 15–30 A 15–30 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
HD, JD
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) VH — — 35–150 A
QO (B) H — 15–100 A —
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) EPE — — 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LD
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–30 A 15–125 A 15–150 A
QO (B) H — 15–100 A —
QO (B) GFI 15–30 A 15–60 A 15–30 A
QO (B) EPD 15–30 A 15–60 A 15–30 A
QO (B) EPE — — 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
Table 9.195: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Maximum
System
Voltage
AC ab
Maximum
Short
Circuit
Current
Rating
Square D™ Brand
Integral or Remote
Main Circuit Breakers
and Remote Main
Fuses
Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef
Type 1 Pole 2 Pole 3 Pole
www.schneider-electric.us
9PANELBOARDS
© 2012 Schneider Electric
All Rights Reserved 9-43
This page last modified
5/14/14
Series Ratings NQ Panelboards
Class 1640
aFor shown circuit breakers rated less than this maximum voltage, the indicated short
circuit current rating also applies, but at the voltage rating of the circuit breaker.
bShort circuit tests are conducted at 100–105% of the maximum rated voltage of the
panelboard.
cSuffixes HID, SWD, and SWN may also be applied to the applicable branch circuit
breakers shown above. Suffix SWN may not be applied in combination with LC main
breakers.
dWhere QO (B) circuit breakers are shown above, QO (B) H, QO (B) VH, and QH (B)
circuit breakers may also be used.
eWhere QO (B) GFI circuit breakers are shown above, QO (B) EPD circuit breakers may
also be used.
fTo acheive selective coordiantion, the rating of the DJ main circuit breaker must be at
least two times greater than the ampere rating of any branch circuit breaker.
Table 9.196: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Maximum
System
Voltage
AC ab
Maximum
Short
Circuit
Current
Rating
Square D™ Brand
Integral or Remote
Main Circuit Breakers
and Remote Main
Fuses
Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef
Type 1 Pole 2 Pole 3 Pole
240/120 V
3P/4W
42,000
LA, MA Q2L–H — 100–225 A 100–225 A
QDL — 70–225 A 70–225 A
LC400A
QO (B) 15–70 A 15–70 A —
QO (B) VH 15–70 A 15–125A 15–100 A
QO (B) GFI 15–30 A 15–60 A 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LC600A
QO (B) VH 15–70 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
MG QO (B) VH 15–30 A 15–30 A 15–30 A
65,000
LC400A
QO (B) 15–30 A 15–30 A —
QO (B) VH 15–30 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LC600A
QO (B) VH 15–30 A 15–125 A 15–150 A
QO (B) GFI — — 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
DJ400A QO (B) 15–70 A 15–125 A —
QO (B) VH — — 15–150 A
QO (B) H — 15–100 A —
DJ_W
QO (B) 15–70 A 15–150 A —
QO (B) VH — 110–125 A 15–150 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
DJ, DG, DL 150–600 A QO (B) EPD — — 15–30 A
EG, FG, KG
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
QG
QO (B) 15–70 A 15–125 A 15–30 A
QO (B) VH — — 35–150 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) PL 15–30 A 15–60 A 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
HG, JG
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) VH — — 35–150 A
QO (B) H — 15–100 A —
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) EPE — — 15–50 A
QO (B) PL 15–30 A 15–60 A 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
FC_ or KC_22___
FC_ or KC_34___
QO (B) 15–70 A 15–100 A 15–100 A
QO (B) AS 15–30 A 15–30 A 15–30 A
LG
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A 15–150 A
QO (B) H — 15–100 A —
QO (B) GFI 15–30 A 15–60 A 15–30 A
QO (B) EPD 15–30 A 15–60 A 15–30 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
LJ
QO (B) 15–70 A 15–125 A —
QO (B) GFI 15–30 A 40–60 A —
QO (B) EPD 15–30 A 40–60 A 15–30 A
QO (B) EPE — — 15–30 A
LL QO (B) EPD — — 15–30 A
QO (B) EPE — — 15–30 A
100,000
FC_ or KC_22___
FC_ or KC_34___
QO (B) GFI 15–30 A 15–30 A —
QO (B) AFI 15–20 A — —
DJ400A
QO (B) 15–70 A 15–125 A —
QO (B) H — 15–100 A —
QO (B) VH — — 15–150 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
EJ QO (B) 15–70 A 15–125 A 15–100 A
LJ
QO (B) 15–70 A 15–125 A —
QO (B) VH 15–70 A 15–125 A 15–150 A
QO (B) H — 15–100 A —
QO (B) GFI — 15–30 A —
QO (B) EPD — 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
HJ, JJ
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) H — 15–100 A —
QO (B) VH — — 35–150 A
QO (B) PL 15–30 A 15–60 A 15–30 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
240/120 V
3P/4
125,000 HL, JL
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) H — 15–100 A —
QO (B) VH — — 35–150 A
QO (B) PL 15–30 A 15–60 A 15–30 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
200,000 FI, KI, HR, JR
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A —
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
208Y/120
3P/4W 200,000
200 A Max. Class T6,
J Fuses
QO (B) 15–70 A 15–125 A —
QO (B) GFI — — 15–50 A
QO (B) EPD — — 15–50 A
400 A Max. Class T3
Fuses
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A 15–50 A
QO (B) EPE — — 15–50 A
QO (B) EPD 15–30 A 15–60 A 15–50 A
240/120 V
3P/4W
42,000 400 A Max. Class T3
Fuses QO (B) VH 15–30 A 15–125 A —
50,000 400 A Max. Class T3
Fuses QO (B) VH — — 15–30 A
65,000
400 A Max. Class J
Fuses
QO (B) VH 15–70 A 15–125 A —
QO (B) EPD — — 15–50 A
QO (B) EPE — — 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
400 A Max. Class T6
Fuses
QO (B) VH 15–70 A 15–125 A 15–150 A
QO (B) AFI 15–20 A — —
100,000 200 A Max. Class
T3 Fuses
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) VH — — 15–30 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) EPE — — 15–50 A
QO (B) AFI 15–20 A — —
QO (B) CAFI 15–20 A — —
QOT 15–30 A 15–30 A —
200,000
200 A Max. Class J or
T6 Fuses
QO (B) EPD — — 15–50 A
QO (B) EPE — — 15–50 A
400 A Max. Class T3
Fuses
QO (B) 15–70 A 15–125 A 15–100 A
QO (B) GFI 15–30 A 15–60 A —
QO (B) EPD 15–30 A 15–60 A 15–50 A
QO (B) EPE — — 15–50 A
Table 9.196: NQ Series Connected Circuit Breaker Ratings (RMS Symmetrical)
Maximum
System
Voltage
AC ab
Maximum
Short
Circuit
Current
Rating
Square D™ Brand
Integral or Remote
Main Circuit Breakers
and Remote Main
Fuses
Square D™ Brand Branch Circuit Breaker
Catalog Designation and Allowable Ampere
Ranges cdef
Type 1 Pole 2 Pole 3 Pole
www.schneider-electric.us
9PANELBOARDS
9-44 © 2012 Schneider Electric
All Rights Reserved
NQ Merchandised
Panelboards
NQ Merchandised Accessories
Class 1640
aWhen selecting a panelboard with SurgeLoc SPD, an additional 12 circuit positions (6
adjacent mounting spaces per side) are occupied. For example, if the desired number of
circuits is 30, refer to Digest Table 9.9 on page 6 and Table 9.10 on page 7 to select the
NQ442L2/NQ442L2C interior and corresponding Box and Trim.
bSPD is only available up to 72 desired circuit counts.
Table 9.197: NQ SurgeLogic SurgeLoc Plug-on SPDab
Vol tage Part Number List
$ Price Poles Occupied
120 / 240 V
80 kA SSP01BIA08PBQ1 4200.
12
100 kA SSP01BIA10PBQ1 4500.
120 kA SSP01BIA12PBQ1 4800.
160 kA SSP01BIA16PBQ1 5300.
200 kA SSP01BIA20PBQ1 6500.
240 kA SSP01BIA24PBQ1 7900.
208 Y / 120 V
80 kA SSP02BIA08PBQ1 4400.
12
100 kA SSP02BIA10PBQ1 4700.
120 kA SSP02BIA12PBQ1 5100.
160 kA SSP02BIA16PBQ1 5550.
200 kA SSP02BIA20PBQ1 7000.
240 kA SSP02BIA24PBQ1 8250.
240 / 120 HLD
80 kA SSP03BIA08PBQ1 4400.
12
100 kA SSP03BIA10PBQ1 4700.
120 kA SSP03BIA12PBQ1 5100.
160 kA SSP03BIA16PBQ1 5550.
200 kA SSP03BIA20PBQ1 7000.
240 kA SSP03BIA24PBQ1 8250.