GE CK Fact Sheet
2014-07-05
: Pdf 108640-Attachment 108640-Attachment 783164 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
MicroVersaTrip Plus™ & MicroVersaTrip PM ™ Conversion Kits for GE Power Circuit Breakers electro-mechanical • tripEasilyunitsreplace with the latest electronic, digital trip unit technology safe, reliable operation with • Ensure ANSI C37.59 tested kits Improve system protection and • increase productivity by eliminating nuisance tripping Integrate mixed switchgear with kits • available for Westinghouse, I-T-E & Allis Chalmers low voltage power circuit breakers GE AKU-2A-50 with MicroVersaTrip PM trip unit upgrade The easy, cost-effective way to increase reliability, enhance performance and extend the life of your existing equipment. GE Industrial Systems Now upgrade your low-voltage power circuit breakers with electronic trip unit technology Normal wear and tear of aging electro-mechanical trip devices on low-voltage power circuit breakers increases susceptibility to loss of calibration that can subsequently jeopardize electrical power system coordination, protection and reliability. GE has channeled its decades of circuit breaker trip system experience into the development of the MicroVersaTrip® Plus and MicroVersaTrip® PM conversion kits for GE, Westinghouse, I-T-E, and Allis Chalmers low-voltage power circuit breakers. ANSI C37.59 design verification tested to ensure safe, reliable operation, these kits are designed to extend the life of your mechanically sound breakers and… • Eliminate costly downtime due to nuisance tripping • Improve electrical power system coordination and protection • Permit easy upgrades to communicating Power Management Control Systems (PMCS) • Provide safe, convenient closed-door local metering via the optional Remote Display MicroVersaTrip Plus conversion kit features • Superior trip unit accuracy and system protection is achieved by taking 64 samples per 60 Hz cycle. This provides true RMS sensing of electrical distribution systems that include AC and DC variable speed drives, rectifiers, induction heaters and other loads that contribute to non-sinusoidal (high-harmonic) current wave forms. • Easy system coordination with maximum flexibility is obtained using multiple trip setpoints, time-delay bands and ramp time functions. • Visual pickup and trip indicators for overload, short circuit and ground fault, display type of fault, phase and current magnitude when applicable • Predictive and preventative maintenance decisions are made easily using the trip operations counter that stores the total number of Long time, Short time, Instantaneous and Ground Fault trips. • Continuously self-testing microprocessor eliminates trip unit bench-testing • Non-volatile memory • High-visibility LCD display • Cold setup capability and target viewing from long-life (5-year) field- replaceable lithium battery – external power not required Standard and optional features • Positive setpoint recognition, values flash until entered and accepted Standard MicroVersaTrip Plus and MicroVersaTrip PM adjustable trip unit functions include: • Easy access 5-button keypad with positive action • Current setting • Long time • Long time delay • Instantaneous • Local fault trip indicators Optional features include: • Short time • Short time delay with or without I2t • Ground fault • Ground fault delay with or without I2t • Switchable instantaneous/short time and ground fault (off) (not UL approved for a listed breaker) • Full function metering (MicroVersaTrip PM) • Protective relaying (MicroVersaTrip PM) • Industry standard open communications capability (MicroVersaTrip PM) • Remote display module • Trip unit test set (TVRMS2) • Phase selectable ammeter (±2% accuracy) • Sealable, clear Lexan protective cover over LCD display and “Enter” key prevents unauthorized access to protective functions and target reset • Interchangeable rating plug • Quick-disconnect trip unit design speeds installation and allows for easy upgrade to MicroVersaTrip PM units with communications capability, full-function metering and optional protective relaying functions Easy conversion kit and rating plug catalog number selection Catalog Number Structure AKO25 C 3 F 06 02 PM Breaker AK-1-15 = AK115 AK-15 = AKO15 7 AK-1-25 = AK125 AK-25 = AKO25 7 AKU-25 AKR-30 AKR-30H = AKR30 AKRU-30 AKR-30S AKRU-30S = AKR3S AK-1-50 = AK150 AK-50 AKU-508 AKT-50 = AKO50 7 AKS-50 AKSU-508 AKST-50 AKR-50 AKR-50H AKRU-50 AKRT-50 AKRT-50H = AKR50 2 AKJ-50 AKJ-50H AKJT-50 AKJT-50H AK-758 = AKO75 3 AKR-75 = AKR75 3 AK-1008 = AKO103 AKR-100 = AKR103 AKW-100 = AKW103 Model C = Generation Wiring 3 Wire = 3 4 Wire1 = 4 Sensor Type F = Fixed CTs Frame 225 600 800 1600 2000 3000 3200 4000 Sensor Rating6 150A = 01 no CTs4 = XA 225A = 02 400A = 04 no CTs4 = XC 600A = 06 800A = 08 no CTs4 = XE 1600A = 16 no CTs4 = XF 2000A = 20 no CTs4 = XG 3000A = 30 3200A5 = 32 no CTs4,5 = XI 4000A = 40 no CTs4 = XJ Sensor Rating Selection Breaker Catalog Numbers Sensors AK-1-15 AK-15 AK-1-25 AK-25 AKU-25 AKR-30, AKR-30H AKRU-30 AKR-30S, AKRU-30S AK-1-50, AK-50, AKU-50, AKS-50, AKSU-50 AKR-50, AKR-50H, AKRU-50, AKJ-50, AKJ-50H AKT-50, AKST-50, AKRT-50, AKRT-50H, AKJT-50, AKJT-50H AK-75 AKR-75 AK-100, AKR-100, AKW-100 150A 225A 150A 225A 600A 150A 400A 800A 800A 1600A 2000A 3000A 3200A 4000A Options Blank = Plus Trip Functions LI = 02 LIG = 03 LSI = 04 LSIG = 05 LS = 06 LSG = 07 LSIGX = 08 LH9 = 09 LHG9 = 10 LSH9 = 11 LSHG9 = 12 M = Metering & Communication PM = Metering, Communication & Protective Relaying Trip Unit Functions LI Long Time & Instantaneous LIG Long Time, Instantaneous & Ground Fault LSI Long Time, Short Time & Instantaneous LSIG Long Time, Short Time, Instantaneous & Ground Fault LS Long Time & Short Time LSG Long Time, Short Time & Ground Fault LSIGX Long Time, Short Time/Inst. & Switchable Ground Fault (off), not approved for a UL Listed breaker LH Long Time & High-Range Instantaneous LHG Long Time, High-Range Instantaneous & Ground Fault LSH Long Time, Short Time & High-Range Instantaneous LSHG Long Time, Short Time, High-Range Instantaneous & Ground Fault 1. Only applicable to trip units with ground fault 2. Not applicable for converting breakers equipped with Power Sensor -contact factory 3. Contact the factory for stationary breaker applications 4. Available only for MicroVersaTrip™ or MicroVersaTrip™ RMS-9 type AKR breakers equipped with fixed current sensors 5. Only available on AKR-75 breaker frames 6. Order rating plug separately, see chart on facing page 7. For converting AK-2 version breakers and newer, not applicable for AK-1 or AKR 8. Breakers equipped with older style open fuse lockout devices (OFLO), must be retrofitted with newer style OFLO device prior to conversion process. Order replacement OFLO kits as follows: AKU-50 - order OFLO kit #121C287OG2, AK-75 - order OFLO kit #121C287OG3, AK-100 - order OFLO kit #121C287OG4 9. High range instantaneous trip function option (H) only available for AKO25 conversion kits Easy conversion kit and rating plug catalog number selection Rating Plugs (Rating plugs priced and ordered separately) Frame Size Sensor Rating Current Rating Current Range (Amps) (Amps) (Amps) (Amps) 60 30-66 80 40-88 225 150 100 50-110 125 63-138 150 75-165 225 100 50-110 or 225 150 75-165 600 225 113-248 300 150-330 400 200-440 600 600 450 225-495 500 250-550 600 300-660 60 30-66 80 40-88 800 150 100 50-110 125 63-138 150 75-165 150 75-165 200 100-220 225 113-248 800 400 250 125-275 300 150-330 400 200-440 300 150-330 400 200-440 800 450 225-495 or 800 500 250-550 1600 600 300-660 700 350-770 800 400-880 Rating Plug Catalog No. TR1B60 TR1B80 TR1B100 TR1B125 TR1B150 TR225B100 TR225B150 TR225B225 TR6B300 TR6B400 TR6B450 TR6B500 TR6B600 TR1B60 TR1B80 TR1B100 TR1B125 TR1B150 TR4B150 TR4B200 TR4B225 TR4B250 TR4B300 TR4B400 TR8B300 TR8B400 TR8B450 TR8B500 TR8B600 TR8B700 TR8B800 Frame Size Sensor Rating Current Rating Current Range (Amps) (Amps) (Amps) (Amps) 600 300-660 800 400-880 1000 500-1100 1600 1600 1100 550-1210 1200 600-1320 1600 800-1760 800 400-880 1000 500-1100 1200 600-1320 2000 2000 1500 750-1650 1600 800-1760 2000 1000-2200 1200 600-1320 1600 800-1760 3000 3000 2000 1000-2200 2500 1250-2750 3000 1500-3300 1200 600-1320 1600 800-1760 3200 3200 2400 1200-2640 3200 1600-3520 1600 800-1760 2000 1000-2200 2500 1250-2750 4000 4000 3000 1500-3300 3600 1800-3960 4000 2000-4400 For details and ordering information, contact your local ED&C sales office, or visit us at www.ge.com/industrialsystems Rating Plug Catalog No. TR16B600 TR16B800 TR16B1000 TR16B1100 TR16B1200 TR16B1600 TR20B800 TR20B1000 TR20B1200 TR20B1500 TR20B1600 TR20B2000 TR30B1200 TR30B1600 TR30B2000 TR30B2500 TR30B3000 TR32B1200 TR32B1600 TR32B2400 TR32B3200 TR40B1600 TR40B2000 TR40B2500 TR40B3000 TR40B3600 TR40B4000 MicroVersaTrip® PM conversion kits— Power management made easy Additional features • Full-function metering* including The enhanced MicroVersaTrip PM trip unit adds power management system capability – including advanced metering and protective relaying – to the basic functions of the MicroVersaTrip Plus. When connected to GE’s Power Management Control System (PMCS), it gives you the power to increase productivity and reduce costs while meeting all your electrical system monitoring needs. You can easily: – current (Amps, kAmps) • Use standard graphics packages that allow the end user to view custom one-lines for metering and trending screens – demand & peak demand (avg. kW, MW) • Analyze energy consumption and power factor trends to minimize utility demand and PF charges or provide low-cost allocations – voltage (Ph-Ph, Ph-N) – energy (kWh, MWh, GWh) – real power (kW, MW) – total power (kVA, MVA) – frequency (Hz) • Optional protective relaying* functions include – undervoltage – overvoltage – voltage unbalance • Collect precise sequences of alarm and event information to speed diagnosis and minimize downtime – current unbalance – power reversal • Use alarm and event logs to assist with preventive maintenance interval planning – power direction setup • Analyze system harmonics (with data input from PQM, EPM 3710, EPM 3720 or EPM 7700 meters) • Communicate with other devices, including Spectra Series™ molded case and Power Break™ insulated case breakers, full-function electronic power meters, programmable logic controllers, GE Multilin protective relays and “smart” motor starters * Requires potential transformer and voltage conditioner inputs (not included in kits – auxiliary panels sold separately) • Utilize GE’s Power Management Control System and its industry standard Modbus RTU, Ethernet TCP/IP open protocols Optional Remote Display • Provides safe, convenient closed-door access to breaker metering, status and setup functions • Available for use with either MicroVersaTrip® Plus or MicroVersaTrip PM trip units • Rugged NEMA Type 1 enclosure with LCD display and keypad • Mounts easily on outside of breaker compartment door • Sealable, clear Lexan protective cover over display and “Enter” key prohibits unauthorized trip setting changes • Connects to breaker trip unit via tough non-flammable, non-toxic 20-pin plug-in cable for fast installation • Breaker trip unit operates independently if cable is disconnected Everything you need in one package GE’s MicroVersaTrip Plus™ and MicroVersaTrip PM™ kits are shipped complete with detailed installation instructions and everything needed for fast and easy trip unit conversions. All kits come complete with: • Digital solid-state trip unit with quick disconnect • Direct-acting flux shifter with automatic reset • Epoxy encapsulated high-accuracy current transformers • Specially designed mounting hardware and wire harnesses with communications cable for each breaker frame • Detailed instruction manual • Interchangeable rating plug (order separately) For details on other MicroVersaTrip Plus and MicroVersaTrip PM conversion kits, ask your ED&C sales engineer for these publications: DET-067B MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for I-T-E Power Circuit Breakers DET-093B MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers DET-226 MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers DEE-019 GE POWER LEADER™ Product Information DEP-041 MicroVersaTrip Plus & MicroVersaTrip PM Remote Display DEP-056A PMCS Auxiliary Panel Components - Pricing & Selection Guide GEP-1100 GE Buylog (Reference for Power Management Components) GE Industrial Systems DET-066B 1198 BL General Electric Company 41 Woodford Avenue, Plainville, CT 06062 www.ge.com/edc © 1998 General Electric Company
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 1998:11:25 15:15:58 Producer : Acrobat Distiller 3.0 for Power Macintosh Creator : QuarkXPress 4.04: LaserWriter 8 8.5.1 Author : Title : GE CK Fact Sheet Modify Date : 1998:11:25 15:23:11 Page Count : 6EXIF Metadata provided by EXIF.tools