Section 8
Operator Mechanisms and
Disconnect Switches
Door-Mounted Switches and Circuit Breaker Mechanisms

UL 508 Motor Disconnect
Switch (p.8-2 )

Motor Disconnect Switches

Mini-Vario and Vario™

10–115 A

8-2

IEC Style Disconnect
Switches

GS1/ GS2 / LK3 / LK4

30–1200 A

8-6

NEMA Style Disconnect
Switches

D10

30–200 A

8-12

Circuit Breaker Mechanisms

9421L

15–1200 A

8-13

UL 98 Fusible Switch
(p. 8-6)

Flange-Mounted and Cable-Operated Disconnect Switches and
Circuit Breaker Mechanisms
Disconnect Switches

9422T

30–400 A

Disconnect Switches,
Bracket Mounted
UL 98 NEMA Style Rotary
Handle Disconnect Switch
(p. 8-12)

9422R Circuit Breaker
Mechanism (p. 8-23)

8-16
8-20

Circuit Breaker Cable
Mechanisms

9422C

Circuit Breaker Mechanisms

9422R

8-22
15–1200 A

Accessories

8-23
8-23

Door Closing Mechanisms
Single-Door or Multi-Door
Closing Mechanisms

9423

Up to 91 in.
door
openings

8-25

9421L Circuit Breaker Mechanism (p. 8-13)

9423 Door Closing
Mechanisms (p. 8-25)

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

9422 Circuit Breaker
Cable Operator (p. 8-16)

8

UL 508 NEMA Style Flange Handle
Disconnect Switch (p. 8-16)

© 2009 Schneider Electric
All Rights Reserved

8-1

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Mini-Vario and Vario™ Assembled and Enclosed Switches

UL 508 Motor Disconnect
Switches

Refer to Catalog 9421CT0301
www.schneider-electric.us

The Mini-Vario and Vario motor disconnect switch catalog
numbers can be identified as described in Table 8.1.

Table 8.1:

Identification System
V

CF

N12

GE

Model (V-Vario, K-Operator)

VCFN12GE

VN12

Operator Type/ Accessory Designation
CD
Single hole Red & Yellow
CF
Four hole Red & Yellow
Single hole Red & Yellow w/extension
CCD
shaft
Four
hole Red & Yellow w/ extension
CCF
shaft
Blank
No operator or accessory
Switch Typea
Blank
N12
Mini-Vario 10/12 A
N20
Mini-Vario 16/20 A
02
Vario 10/12 A
01
Vario 16/20 A
0
Vario 20/25 A
Enclosure Type (if applicable)
Blank
No Enclosure
Mini-Vario IP55
GE
Non-Metallic
a

BD
BF

Z

Single hole Black & Gray
Four hole Black and Gray
Switch with Red handle installed on unit
(one padlock only)
Switch with Black handle installed on unit
(no padlock provision)
Accessory, power pole, neutral or ground

1
2
3
4
5
6

Vario 20/32 A
Vario 25/40 A
Vario 45/63 A
Vario 63/80 A
Vario 100/125 A
Vario 115/175 A

VE
VD

G30, A30, W30 Type 1/12/4/4X Metallic (Class 9421)
GU

Vario IP55 Non-Metallic

Switches/contacts are dual rated (UL/IEC).

Mini-Vario
Table 8.2:

Assembled Switches—IP65

VN12/KCC1YZ

Red/Yellow (Single Hole)
UL/IEC
10/12 A
16/20 A

Table 8.3:

Catalog Number
VCDN12
VCDN20

Black/Gray (Single Hole)

$ Price
90.00
135.00

Catalog Number
VBDN12
VBDN20

Red/Yellow Mounted In Sealable Enclosure, Non-UL Listed
Catalog Number
VCFN12GE
VCFN20GE

$ Price
179.00
189.00

VBDN12

Catalog
Number
VN12a
VN20a
VZN12a
VZN20a

8
VCDN12

$ Price
90.00
135.00

Table 8.5:

Enclosed Switches

Complete Switches Mounted in IP55 Non-metallic Enclosure

Table 8.4:

Complete Switches for Rear Mounting,
Includes Extension Shaft (3-Padlock)

Complete Switches for Door Mounting (3-Padlock)

Current Rating

Component Parts
Description

Catalog
Number
KCC1YZ
KCD1PZ
KAD1PZ
VZN17
VZN30
KZ32
KZ83

Red/Yellow (Single Hole)
Catalog Number
VCCDN12
VCCDN20

$ Price
134.00
161.00

Operators and Accessories
Description

$ Price

45 x 45 mm Red & Yellow operator
60 x 60 mm Red & Yellow operator
60 x 60 mm Black & Gray operator
300–340 mm shaft extension
400–430 mm shaft extension
Door interlocking plate for 45 or 60 mm operator
Door mounting plate for 45 or 60 mm operator

39.20
39.20
39.20
22.50
27.00
20.30
20.30

$ Price

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

10/12 A switch only
16/20 A switch only
Add on power pole for 10/12 A switch
Add on power pole for 16/20 A switch
Neutral Pole with early make, late break for VN12 or
VZN11
VN20 switch
VZN14
Grounding module for VN12 or VN20
VZN05
N.O. late make auxiliary contactb
VZN06
N.C. early break auxiliary contactb
VZN26
Single-pole shroud for auxiliary contacts
VZN08
Three-pole shroud for VN12 or VN20
a
Switches/contacts are dual rated (UL/IEC).
b
Auxiliary contacts are dual rated (UL/IEC 10/12 A).

52.00
63.00
26.00
31.50
29.30
29.30
27.00
27.00
5.90
7.70

VCCDN20

8-2

CP1

Discount
Schedule

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Mini-Vario and Vario™ Switches

UL 508 Motor
Disconnect Switches

Refer to Catalog 9421CT0301

www.schneider-electric.us

Vario
Table 8.6:

NEMA Type 1 and 12 Assembled Switches for Door Mounting
Complete Switches (Switch and Handle) for Door Mounting (3-padlock)

Operator
Style

Red/Yellow (Four Hole)

Black/Gray (Four Hole)

UL/IEC
10/12 A
16/20 A
20/25 A
20/32 A
25/40 A
45/63 A
63/80 A
100/125 A
115/75 A

Catalog No.
VCF02
VCF01
VCF0
VCF1
VCF2
VCF3
VCF4
VCF5
VCF6

Catalog No.
VBF02
VBF01
VBF0
VBF1
VBF2
VBF3
VBF4
VBF5
VBF6

Table 8.7:

$ Price
125.00
147.00
174.00
185.00
237.00
282.00
329.00
401.00
612.00

Red/Yellow (Single Hole) Black/Gray (Single Hole)

$ Price
125.00
147.00
174.00
185.00
237.00
282.00
329.00
401.00
612.00

Catalog No.
VCD02
VCD01
VCD0
VCD1
VCD2
—
—
—
—

$ Price
134.00
161.00
206.00
219.00
252.00
—
—
—
—

Catalog No.
VBD02
VBD01
VBD0
VBD1
VBD2
—
—
—
—

$ Price
134.00
161.00
206.00
219.00
252.00
—
—
—
—

NEMA Type 1 and 12 Assembled Switches for Rear Mounting
Complete Switches for Rear Mounting
with Extension Shaft (3-Padlock)a

Operator
Style

Switches with Handles Installed
on Unit, DIN Rail Mount Only

Red/Yellow (Four Hole) Red/Yellow (Single Hole) Red/Yellow (1-Padlock) Black/Gray (No-Padlock)

UL/IEC
Catalog No.
$ Price Catalog No.
$ Price Catalog No.
$ Price Catalog No.
10/12 A
VCCF02
162.00
VCCD02
162.00
—
—
—
16/20 A
VCCF01
185.00
VCCD01
185.00
—
—
—
20/25 A
VCCF0
197.00
VCCD0
197.00
VVE0
149.00
VVD0
20/32 A
VCCF1
206.00
VCCD1
206.00
VVE1
156.00
VVD1
25/40 A
VCCF2
252.00
VCCD2
252.00
VVE2
180.00
VVD2
45/63 A
VCCF3
320.00
—
—
VVE3
212.00
VVD3
63/80 A
VCCF4
356.00
—
—
VVE4
300.00
VVD4
100/125 A
VCCF5
464.00
—
—
—
—
—
115/75 A
VCCF6
606.00
—
—
—
—
—
a
Complete switch includes handle operator, shaft, door interlock plate, and line terminal shroud.

Metallic Enclosure

Non-Metallic Enclosure

Metallic Enclosed Switch Dimensions

6.88

Table 8.8:

8

5.38

175

Non-Metallic Enclosed Switches a b

IP55-PVC 3-Pole, NEMA Type 1 & 12
Catalog No.
$ Price
20/32
VC1GU
239.00
25/40
VC2GU
287.00
45/63
VC3GU
345.00
63/80
VC4GU
381.00
100/125
VC5GU
548.00
115/175
VC6GU
845.00
Assembled, includes switches mounted in enclosure with handle.
Refer to Table 8.11 and Table 8.12 for horsepower ratings.

Ampere Size
UL/IEC

.31

137

a
b

4.25

5.63

108

143

5.88
149

The V1 and V2 come in metallic enclosures (NEMA Type 1, 4, 4X, and 12). The NEMA
Type 1 is supplied with conduit knockouts top and bottom. A VZ7 auxiliary contact can be
factory installed in these metallic enclosures by adding Form X11 to the catalog number. A
VZ20 auxiliary contact can be factory installed in these enclosures by adding Form X20 to
the catalog number. Price Adder $42.00

NEMA Type 1 V1G30, V2G30

3.00
76

Table 8.9:
7.38

6.75

187

171

114

140

6.25
159

NEMA Type 4, 4X, 12
V1W30, V2W30, V1A30, V2A30

Ø 6.2

Table 8.10:

600 V

e
b

VC1GU–VC6GU

NEMA Type 1
Catalog No.

NEMA Type 12

$ Price Catalog No.

$ Price

NEMA Type 4/4Xb
Catalog No.

$ Price

Non-Metallic Enclosed Switch Dimensionsa
No.
of
Poles

Catalog No. a

Table 8.11:
d a

© 2009 Schneider Electric
All Rights Reserved

480 V

a

in.
VC1GU–VC2GU
3
6.7
VC3GU–VC4GU
3
6.7
VC5GU–VC6GU
3
11.0
a
UL Rated, NEMA Type 1, 12, IP55.

.25

Legend
Plate
Holder

240 V

20/32
5
10
10
9421V1G30
333.00 9421V1A30
548.00 9421V1W30
783.00
25/40
5
10
15
9421V2G30
381.00 9421V2A30
594.00 9421V2W30
831.00
a
Assembled, includes: switches mounted in enclosure with handle.
b
For indoor use only. The NEMA 4/4X enclosure is made of #304 stainless steel with 3/4 in. T&B stainless steel hubs
on the top and bottom.

4.50

5.50

Metallic Enclosed Switches a b
Horsepower Ratings

Ampere Size
UL/IEC

f

12
20
25
32
40
63
80
125
175

CP1

mm
170
170
280

in.
4.1
5.3
8.6

mm
105
135
220

in.
3.2
3.3
5.0

Dimensions
c
d
mm
in.
mm
82
4.8
122
85
5.1
130
126
7.9
201

e
in.
2.1
3.7
7.5

f
mm
53
95
190

in.
5.0
5.2
8.6

mm
128
131
203

Vario Manual Motor Control Switches, IEC

Ampere Size
IEC

c

b

Discount
Schedule

230 V
3
4
5.5
5.5
7.5
15
18.5
22
30

kW Rating
240 V
400 V
3
4
4
5.5
5.5
7.5
5.5
11
7.5
15
15
22
18.5
30
22
37
30
45

415 V
4
5.5
7.5
11
15
22
30
37
45

3-Pole Switch Body
500 V
690 V
5.5
7.5
7.5
11
11
15
11
15
18.5
15
30
22
37
30
45
37
55
45

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

76

The Vario Motor Disconnect Switch is also offered as an enclosed switch, which is made of
corrosion resistant material. The 3-pole version makes the Vario switch ideal for manual
motor control applications. They are compact, easy to wire and connect, and come undrilled
to allow variable cable entry positions. Note: VCGU enclosures are UL approved.

8

3.00

$ Price
—
—
149.00
156.00
180.00
212.00
300.00
—
—

8-3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

UL 508 Motor
Disconnect Switches

Mini-Vario and Vario™ Switches
Refer to Catalog 9421CT0301
www.schneider-electric.us

Table 8.12:
Ampere
Size
UL
10
16
20
20
25
45
63
100
115

Vario Manual Motor Control Switches

Vario Manual Motor Control
Switches, UL
Horsepower Rating

240 V
2
3
5
5
5
10
15
25
30

480 V
5
7.5
10
10
10
20
30
50
50

600 V
5
7.5
10
10
15
30
40
50
60

Shaft
Size

3-Pole Switch
Body

mm
6
6
6
6
6
8
8
8
8

Type
V02
V01
V0
V1
V2
V3
V4
V5
V6

Vario switches act as enclosure disconnects when short
circuit protection is provided upstream of the switch (if
short circuit protection is not provided upstream, use
GS1, LK3, Class 9422 Type T or D10 disconnect
switches). Type V switches meet UL 508 requirements
as manual motor controllers.
Table 8.13:
Ampere Size
UL/IEC

NEMA Type 1 and 12 Handle Operators: V02–V2 (6 mm Shaft), V3–V6 (8 mm Shaft) a
Red/Yellow Single Hole
45 x 45 mm

Operator Type
Switches
V02–V2
V02–V2

No. of
Padlocks
0
1

Catalog No.

V02–V2
V3–V4
V02–V2
V3–V4

$ Price

Catalog No.

$ Price

KCE1LZ
39.20
KCE1YZ
39.20
Red/Yellow Four Hole
60 x 60 mm

Black/Gray Single Hole
45 x 45 mm
Catalog No.

$ Price

KDD1PZ
39.20
KDF1PZ
39.20
KBD1PZ
—
—
KDF2PZ
39.20
—
KCD1PZ
39.20
KCF1PZ
39.20
KAD1PZ
—
—
KCF2PZ
39.20
—
Red/Yellow Four Hole
Black/Gray Four Hole
Operator Type
90 x 90 mm
90 x 90 mm
V5–V6
0
KDF3PZ
107.00
KBF3PZ
107.00
V5–V6
3
KCF3PZ
107.00
KAF3PZ
107.00
a
When using these handles for replacements on the non-metallic enclosed switches (see page 8-3),
the handle shaft supplied with the enclosure must be reused.

Switches

39.20
—
39.20
—

Red/Yellow Single Hole
60 x 60 mm

No. of
Padlocks
3
3

Catalog No.

Red/Yellow Four Hole
60 x 60 mm

$ Price

Catalog No.

$ Price

Black/Gray Single Hole
60 x 60
Catalog No.

39.20
—

Catalog No.

$ Price

KAF1XZ
KAF2XZ

39.20
39.20

Description
45 x 45 mm Gasket for V02-V2 for 4-hole type handles (order in quantities of 5)—IP65
60 x 60 mm Gasket for V02-V2 for 4-hole type handles (order in quantities of 5)
60 x 60 mm Gasket for V3-V4 for 4-hole type handles (order in quantities of 5)
90 x 90 mm Gasket for V5-V6 for 4-hole type handles (order in quantities of 5)—IP65
5.5

8

13

5.5

48

12.7

$ Price
5.90
12.00
12.00
15.60

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Single-Hole
Mounting Dimensions

13

68

48

22.5

Four-Hole 60 x 60
Mounting Dimensions a

Four-Hole 90 x 90
Mounting Dimensions a

The door interlock plate included with VCC Kits has the same drilling as the handle operators.

Table 8.17:

Rear/Panel Mounting Switch Body Dimensions
Dimensions

Type

V02 to V2
V3 to V4
V5 to V6

8-4

39.20
39.20
39.20
39.20

Gasket Kits

Catalog No.
KZ65
KZ66
KZ62
KZ67
3

Low-Profile Handle
KCD1YZ

KBF1PZ
KBF2PZ
KAF1PZ
KAF2PZ

68

Table 8.16:

a

$ Price

KAE1BZ
39.20
—
—
Black/Gray Four Hole
60 x 60 mm

Black/Gray Four Hole
60 x 60 mm

$ Price

KCD1YZ
39.20
KCF1YZ
39.20
KADIXZ
—
—
KCF2YZ
39.20
—
Red/Yellow Four Hole
Black/Gray Four Hole
Operator Type
90 x 90 mm
90 x 90 mm
V5–V6
3
KCG2YZ
72.00
KAG2XZ
72.00
a
When using these handles for replacements on the non-metallic enclosed switches (see page 8-3),
the handle shaft supplied with the enclosure must be reused.

Four-Hole Operator
KDF3PZ and KBF3PZ

Catalog No.

Low Profile Handle Operatorsa

Operator Type

V02–V2
V3–V4

Black/Gray Four Hole
45 x 45 mm

KAC1BZ
39.20
—
—
Black/Gray Single Hole
60 x 60 mm

0
0
3
3

Table 8.15:
Four-Hole Operator
(All except KDF3PZ
and KBF3PZ)

Red/Yellow Four Hole
45 x 45 mm

KCC1LZ
39.20
KCC1YZ
39.20
Red/Yellow Single Hole
60 x 60 mm

Operator Type

Single-Hole Operator

3 Pole Switch Body

Shaft Size
mm

Type
$ Price
10/12
6
V02
62.00
16/20
6
V01
74.00
20/25
6
V0
84.00
20/32
6
V1
95.00
25/40
6
V2
143.00
45/63
8
V3
179.00
63/80
8
V4
215.00
100/125
8
V5
287.00
115/175
8
V6
428.00
a
Refer to Table 8.11 and Table 8.12 for horsepower ratings.

Manual Motor
Control Switch

Table 8.14:

Switch Bodya

Shaft
Extension
VZ17
VZ30
VZ18
VZ31
VZ18
VZ31

a
in.
5.5–13.0
5.5–16.9
5.5–12.6
5.5–16.5
6.5–13.8
6.5–17.7

1.5-6

b
mm
140–330
140–430
140–320
140–420
165–350
165–450

CP1

in.
0.60

c
mm in. mm
15

in.

dia. d

mm

2.4

60

0.17 4.2

60

0.20 5.2

0.79

20

2.4

1.20

30

3.9 100 0.28 7.0

c

1.73

Discount
Schedule

b

d

44

a

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Mini-Vario and Vario™ Accessories

UL 508 Motor
Disconnect Switches

Refer to Catalog 9421CT0301

www.schneider-electric.us

13

.217

.512
.217

a

2.68

48

b

Door Mounting Switch Body Dimensions

Switch Type

68

1.89
44

Table 8.18:

Dimensions

2.68

c 1.89
48

1.73

13

5.5

5.5

68

in.
13.0
12.6
13.8
16.9
16.5
17.7

V02 to V2
V3, V4
V5, V6
V02 to V2
V3, V4
V5, V6

Table 8.20:
Switch Type
V02 to V2
V3, V4
V5, V6

Table 8.21:

Shaft Extension Kit

a
b

Shaft
Extension
Kit

mm
330
320
351
429
419
450

Switch
Type
V02–V2
V3–V4
V5–V6

VZ17
VZ18
VZ18
VZ30
VZ31
VZ31

Line Side
Terminal Shroud
For Main Switch
VZ8
VZ9
VZ10

Terminal Shroud for
Main Switch
VZ8

20.30
39.20
39.20
20.30
39.20
39.20

Terminal Shroud
for Auxiliary
Contact
VZ29
VZ29
VZ29

$ Price
5.90
5.90
9.50

$ Price

10/12
16/20
20/25
20/32
25/40
45/63
63/80
—
—

1 N.O. &
1 N.C. a

2 N.O.

VZ7b

VZ20b

31.50
32.90
34.20
35.60
55.00
66.00
82.00
—
—

Grounding
Module

$ Price
5.90
5.90
5.90

$ Price

42.80

Auxiliary Contacts

$ Price Catalog No. $ Price Catalog No.
Description
$ Price
42.80
VZ14
42.80
VZ7
1 Late Make N.O. & 1 Early Break N.C.
42.80
54.00
VZ15
54.00
VZ20
2 N.O. Contacts
42.80
70.00
VZ16
70.00
—
—
—

Labeling Accessories
Nameplate Holder Only

$ Price
4.80
4.80
7.80

Catalog No.
KZ14
KZ16
KZ101

$ Price
4.40
4.40
6.80

Nameplate Only
Use With
KZ14
KZ16
KZ1010

Catalog No.
KZ76
KZ77
KZ100

$ Price
3.50
3.50
3.50

Shrouds
3-Pole Shroud

Table 8.25:

KZ83
KZ81
KZ81
KZ83
KZ81
KZ81

Add-On Contact Modules

Catalog No.
VZ8
VZ9
VZ10
—

V02–V2
V3–V4
V5–V6
—

20.30
39.20
39.20
20.30
39.20
39.20

$ Price

Auxiliary Contacts

Ampere
Rating
UL/IEC

Main
Pole

Catalog No.
KZ13
KZ15
KZ103

Switch Type

0.44
0.44
1.10
2.00

Door
Mounting
Plate

$ Price

KZ32
KZ74
KZ74
KZ32
KZ74
KZ74

Terminal Shroud
for Add-on
Power Pole
VZ26
VZ27
VZ28

8.40
8.40
12.00

Nameplate Holder with Nameplate

Table 8.24:

mm
74
74
83
125

Add-On Contact Modules

Catalog No.
VZ11
VZ12
VZ13

Size
45 x 45 mm
60 x 60 mm
90 x 90 mm

in.
2.91
2.91
3.27
4.92

Door
Interlock
Plate

28.70
35.60
35.60
35.60
42.80
42.80

$ Price

Neutral Modules Early
Make/Late Break

Table 8.23:

Terminal Shroud
for Auxiliary Contact
VZ29

$ Price

V02
VZ02
VZ02
V01
VZ01
VZ01
V0
VZ0
VZ0
V1
VZ1
VZ1
V2
VZ2
VZ2
V3
VZ3
VZ3
V4
VZ4
VZ4
V5
—
—
V6
—
—
Early Break, Late Make.
Auxiliary contacts are rated UL/IEC 10/12 A.

Table 8.22:

mm
55
55
60
90

Accessories

Main Pole
Module

Switch Type

Weight
Approx. lbs.

c

in.
2.17
2.17
2.36
3.54

Shaft Extension and Door Interlock
Maximum
Panel Depth

Switch Type

Add-On Contact Modules

b

in.
mm
V02 to V2a
2.83
72
V02 to V2
2.36
60
V3 to V4
2.56
65
V5 to V6
3.54
90
a
Dimensions for single-hole mounting.

Table 8.19:

Door Interlock Plate
KZ32

a

Single-Pole Shroud
$ Price
8.40
8.40
12.00
—

For Add-On Power Pole
VZ02-VZ2, VZ11 & VZ14
VZ23, VZ4, VZ12 & VZ15
VZ13 & VZ16
For 2-Pole Aux. Contact

Catalog No.
VZ26
VZ27
VZ28
VZ29

$ Price
5.90
6.90
9.50
5.90

Main Pole Module Dimensions
Dimensions

b
Switch Type

c

V02 to VZ2
VZ3 to VZ4

in.
0.63
0.79

b
mm
16
20

in.
2.9
3.3

Weight
Approx. lbs.

c
mm
74
83

in.
1.38
1.80

mm
35
46

0.10
0.22

8

a

a

Main Pole Module
© 2009 Schneider Electric
All Rights Reserved

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

.512

1.5-6

CP1

Discount
Schedule

8-5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

IEC Style Disconnect
Switches

GS1/GS2 Fusible and LK3/LK4 Non-Fusible, UL 98 Listed
Refer to Catalog 9421CT0301
www.schneider-electric.us

Identification System
The GS1 part numbers can be identified as follows:
(See Catalog 9421CT0301 for specific applications.)

GS1

D

U

3

Model “GS1”, “GS2”—Fusible (Class J Fuse unless noted), “LK3”, “LK4”—Non-Fusible
Current Range, Operator Style (Front Operator unless noted), Accessory Type
“D”—30 A Front and Side Operation, “DD”—30 A Class CC Front and Side Operation “E”—30 A,
“EE”—30 A Class CC, “G”—60 A, “J”—100 A, “M”—200 A, “Q”—400 A, “S”—600 A, “T”—800 A
(Class L if Fused), “U”—1000 A, “W”—1200 A
UL Certification
Poles—Number of Poles 2 or 3
“AH”—Handle, “AHT”—Handle w/ Test, “AE”—Extension Shaft, “AD”—Aux contact holder, “AM”—Aux Contact

Note: All fusible switches through 400 A and non-fused switches through 200
A are equipped with a feature to test optional auxiliary contacts without
energizing the load when the appropriate GS1AHT*** handle is used.

Table 8.26:
Catalog
Number

Table 8.28:

Switches — Fusible
Description

$ Price

Compact GS1 Fusible IEC Style Disconnect Switches
GS1DDU3
30 A, 3-Pole, Class CC, use 5 x 5 Shaft
GS1DU3
30 A, 3-Pole, Class J, use 5 x 5 Shaft

200 A Switch
GS2MU3

GS2 Fusible IEC Style Disconnect Switches
GS2EEU3
30 A, 3-Pole, Class CC , use 10 x 10 Shaft
GS2EU3
30 A, 3-Pole, Class J, use 10 x 10 Shaft
GS2GU3
60 A, 3-Pole, Class J, use 10 x 10 Shaft
GS2JU3ab 100 A, 3-Pole, Class J, use 10 x 10 Shaft
GS2MU3ab 200 A, 3-Pole, Class J, use 10 x 10 Shaft
GS2QU3ab 400 A, 3-Pole, Class J, use 10 x 10 Shaft
GS2SU3ab 600 A, 3-Pole, Class J, use 15 x 12 Shaft
GS2TU3ab 800 A, 3-Pole, Class L, use 15 x 12 Shaft

Table 8.27:
Catalog
Number

30 A Side Handle
GS1EERU30

237.00
260.00

237.00
260.00
336.00
536.00
1181.00
2252.00
3378.00
5061.00

Catalog
Number

Switches — Non-Fusible
Description

$ Price

Compact LK3 Non-Fusible IEC Style Disconnect Switches
LK3/LK4DU3 30 A, 3-Pole, 5 x 5 Shaft
LK4 Non-Fusible IEC Style Disconnect Switches
LK4GU3
60 A, 3-Pole, use 10 x 10 Shaft
LK4JU3
100 A, 3-Pole, use 10 x 10 Shaft
LK4MU3ab 200 A, 3-Pole, use 10 x 10 Shaft
LK4QU3ab 400 A, 3-Pole, use 15 x 15 Shaft
LK3SU3ab 600 A, 3-Pole, use 15 x 12 Shaft
LK3TU3ab 800 A, 3-Pole, use 15 x 12 Shaft
LK3UU3ab 1000 A, 3-Pole, use 15 x 12 Shaft
LK3WU3ab 1200 A, 3-Pole, use 15 x 12 Shaft

218.00

263.00
458.00
1010.00
1910.00
2873.00
4301.00
5372.00
6450.00

Switches — Fusible with Direct Mount
Side Handle
Description

$ Price

Switches with Direct Mount Side Handle
GS1EERU20 30 A, 2-Pole, Class CC
204.00
GS1EERU30 30 A, 3-Pole, Class CC
242.00
Right Side Handle for
GS1AH01
46.40
GS1EERU20 & GS1EERU30
a
Shipped with line side terminal shrouds, for additional shrouds see
page 8-8.
b
Terminal lug must be ordered separately—see page 8-8.

Compact 30 A Switch
LK3DU3

Example of the parts to order to build a complete switch:
Choose a switch

+

Shaft

+

Handle Assembly

+

Lugs if needed

8
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

600 A
LK3SU3

8-6

Shaft 200 mm
GS2AE5

Black Handle
GS2AH150

Lugs Kit
GS1AW503

For example:

To add auxiliary contacts:

LK3SU3 (600 A Non-Fusible Switch, use 15 x 12 Shaft) +
GS2AE6 (15 x 12 200 mm Type S Shaft) + GS2AH150
(Black/ Black, Lockable)

For front mounted contacts order LK3AD30 (front
mounted auxiliary contact holder) + GS2AM110 (N.O.
contact for GS1AD10, GS2AD11, and LK3AD30).

CP1

Discount
Schedule

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

IEC Style Disconnect
Switches

GS1/GS2 Fusible and LK3/LK4 Non-Fusible, UL 98 Listed
Refer to Catalog 9421CT0301

www.schneider-electric.us

Handles

Type D
Alternate Handles for
Compact Switches
Only
Economical
Handle Design

Table 8.29:
NEMA/UL Type
1, 12
1, 12

Compact Shaft Kits

Table 8.30:
GS1AH101

GS1AH102
NEMA/UL Type
1, 3R, 12
1, 3R, 12
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12

GS1AE7/AE71 Shafts

Type S
Standard
Handle Design

Table 8.31:
Use these shaft
kits when using
Compact Switches

NEMA/UL Type

GS2AH110
GS2AH120

GS2AE8/AE81 Shafts

NEMA/UL Type

GS2AH120

IEC Type
IP54
IP54

Defeatable
Yes
Yes

Padlockable
Yes
Yes

Color
Black
Red/Yellow

IEC Type
IP54
IP54
IP54
IP54
IP65
IP65
IP65
IP65

Defeatable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Padlockable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Color
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow

Catalog No.
GS1AH101
GS1AH102

$ Price
51.00
51.00

Operation
Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)
Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)

Catalog No.
GS2AH110
GS2AH120
GS2AHT110
GS2AHT120
GS2AH410
GS2AH420
GS2AHT410
GS2AHT420

$ Price
62.00
62.00
117.00
117.00
70.00
70.00
117.00
117.00

Pistol Handles for Standard GS2 and LK4 (as listed below)
IEC Type

Defeatable

Padlockable

Color

Operation

Catalog No.

$ Price

Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow

Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)
Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)

GS2AH110
GS2AH120
GS2AHT110
GS2AHT120
GS2AH410
GS2AH420
GS2AHT410
GS2AHT420

62.00
62.00
117.00
117.00
70.00
70.00
117.00
117.00

Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow

Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)
Off/On (O/I)
Off/On (O/I)
Test/Off/On (T/O/I)
Test/Off/On (T/O/I)

GS2AH130
GS2AH140
GS2AHT130
GS2AHT140
GS2AH430
GS2AH440
GS2AHT430
GS2AHT440

70.00
70.00
125.00
125.00
78.00
78.00
132.00
132.00

Pistol Handles for Use with Shaft Type S (as listed below)
IEC Type

Defeatable

Padlockable

Color

For LK3 400–1200 A
1, 3R, 4, 4X, 12
IP65
Yes
Yes
Black
1, 3R, 4, 4X, 12
IP65
Yes
Yes
Red/Yellow
For GS2 600–800 A
1, 3R, 4, 4X, 12
IP65
Yes
Yes
Black
1, 3R, 4, 4X, 12
IP65
Yes
Yes
Red/Yellow
Note: Now UL approved for indoor or outdoor applications.

Table 8.33:

Operation
Off/On (O/I)
Off/On (O/I)

Pistol Handles for Compact and Standard GS1/GS2 and LK3/LK4 for
Compact GS1, 30 A, and Compact LK3 30 A (3 in. handles) for Use with
Shaft Type S (as listed below)

GS2 30–100 A and LK4 60–100 A (3 in. handles)
1, 3R, 12
IP54
Yes
Yes
1, 3R, 12
IP54
Yes
Yes
1, 3R, 12
IP54
Yes
Yes
1, 3R, 12
IP54
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes
GS2 200–400 A and LK4 200 A (5 in. handles)
1, 3R, 12
IP54
Yes
Yes
1, 3R, 12
IP54
Yes
Yes
1, 3R, 12
IP54
Yes
Yes
1, 3R, 12
IP54
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes
1, 3R, 4, 4X, 12
IP65
Yes
Yes

Table 8.32:
GS2AH110

Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type D
(as listed below)

Operation

Catalog No.

$ Price

Off/On (O/I)
Off/On (O/I)

GS2AH150
GS2AH160

263.00
263.00

Off/On (O/I)
Off/On (O/I)

GS2AH150
GS2AH160

263.00
263.00

Shafts
Length

in.

mm

Catalog No.

$ Price

Shaft 5 mm x 5 mm—for Use with Pistol Handles, Type D
12.6
15.7

320
400

GS1AE7
GS1AE71

18.60
23.30

GS2AE8
GS2AE81

18.60
23.30

GS2AE2
GS2AE21

20.30
25.00

GS2AE5
GS2AE51

32.60
40.40

GS2AE5 / AE51

12.6
15.7

320
400

Shaft 10 mm x 10 mm—for Use with Standard GS2 and LK4
12.6
15.7

320
400

Shaft 15 mm x 12 m—for Use with Pistol Handles
7.9
15.7

200
400

8

GS2AE2/AE21
Shafts

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Shaft 5 mm x 5 mm—for Use with Pistol Handles, Type G

GS2AH160

© 2009 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

8-7

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

IEC Style Disconnect
Switches

GS1/GS2 Fusible and LK3/LK4 Non-Fusible, UL 98 Listed
Refer to Catalog 9421CT0301
www.schneider-electric.us

Accessories
Table 8.34:

Auxiliary Contacts

Type

Description

Catalog No.

$ Price

For Compact LK3 / GS1
Contact holder (for 5 to 8 auxiliary contacts). Standard products allow GS1AD10
46.70
up to 4 auxiliary contacts without any extra contact holders.
10 A
1 N.O. Contact Block
GS2AM110
14.70
600 Vac
1 N.C. Contact Block
GS2AM101
14.70
For LK4 60–200 A, GS2 30–800 A
U = Upper or Top mounted
Contact holder required (for 1 to 8 upper auxiliary contacts)
GS2AD11
46.70
10 A
1 N.O. Contact Block
GS2AM110
14.70
600 Vac
1 N.C. Contact Block
GS2AM101
14.70
1 N.O. & N.C. Contact Block (max of two blocks – any mix)
GS1AN11
78.00
S = Side mounted a
2 N.O. & N.C. Contact Block (max of two blocks – any mix)
GS1AN22
140.00
1 N.O. & N.C. Contact Block w/ Test (max of two blocks – any mix)
GS1ANT11
93.00
S = Side mounted a
2 N.O. & N.C. Contact Block w/ Test (max of two blocks – any mix)
GS1ANT22
156.00
For LK3 400–1200 A
U = Upper or Top mounted
Contact holder (for 1 to 4 auxiliary contacts)
LK3AD30
46.70
10 A
1 N.O. Contact Block
GS2AM110
14.70
600 Vac
1 N.C. Contact Block
GS2AM101
14.70
a
GS1AN• • contact blocks cannot be mixed with GS1ANT• • contact blocks on the same switch. You must use all
GS1AN11/GS1AN22 on a single switch OR all GS1ANT11/GS1ANT22 on a single switch.
U = Upper or Top mounted

GS2AM110 +
GS2AM101

GS1AD10 +
GS2AM110

Table 8.35:

Terminal Lugs

For use on

# of Wires
per Lug
1
1
1
1
1
1
1

Wire Size

Wire Type

Lugs per Kit

Catalog No.

$ Price

Compact GS1/LK3
#14–#10
Cu
—
Standard
—
GS2 30 A CC
#14–#10
Cu
—
Standard
—
GS2 30 A J
#14–#10
Cu
—
Standard
—
GS2/LK4 60 A J
#10–#3
Cu
—
Standard
—
LK4 100 A
#14–#2/0
Cu
—
Standard
—
GS2 100 A
#14–2/0
Cu/Al
6
GS1AW303
59.00
GS2/LK4 200 A
#6–3/0
Cu/Al
6
GS1AW403
98.00
GS2 400–800 A
2 x 2–2 x 600
2
Cu/Al
6
GS1AW503
197.00
LK3 400–600 A a
LK3 800–1200 A a
4 x 2–4 x 600
2
Cu/Al
12
GS1AW903
395.00
a
GS1 600–800 A and LK3 800–1250 A can receive 1 lug for 3 cables per terminal or 2 lugs for 2 cables per terminal.

Terminal
Lugs

Table 8.36:
For use on
GS2JU3
GS2MU3
GS2QU3

GS2MU3
GS2QU3

Power Distribution Lugs
Wire Size
AWG (mm2)
#8 (10) – #6 (16)
#14 (2.1) – #10 (6)
#6 (16) – #4 (35)
#8 (10)
#14 (2.1) – #10 (6)
#2 (35) – #2/0 (70)
#6 (16) – #4 (25)
#8 (10)
#12 (3.3) – #10 (4)

Table 8.37:

Terminal Shrouds

# of Wires
Per Lug

Wire
Type

Lugs per
Kit

Catalog Number

$ Price

6

Cu

3

GS1AW306

126.00

12

Cu

3

GS1AW406

209.00

6

Cu

3

GS1AW506

233.00

Terminal Shrouds

8

For use on Line or Load Side a
Compact GS1/LK3
All GS2/LK4 30 A
All GS2/LK4 60 A
LK4 100 A
GS2 100 A b
GS2/LK4 200 A b
GS2 400 A
LK3 400–600 A
GS2 600–800 A
LK3 800–1200 A
a
All GS1 and LK3 switches supplied with line side shrouding.
b
Three piece kit for either line or load side.

Table 8.38:
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Shorting Links per Kit
3
3
3
3
3

Table 8.39:

8-8

Catalog No.
GS1AU203
GS1AU303
GS1AU403
GS1AU503
GS1AU803

$ Price
29.60
41.90
62.10
93.00
156.00

Shaft Padlocking Kit

For use on
Compact GS1/LK3
LK4 60–200 A
GS2 30–400 A
LK3 400–1200 A
GS2 600–800 A

CP1

$ Price
—
—
—
—
101.00
132.00
140.00
86.00
140.00
101.00

Shorting Links

For use on
GS2 60 A
GS2 100 A
GS2 200 A
GS2 400 A
GS2 600–800 A

Shorting Links

Catalog No.
Standard
Standard
Standard
Standard
GS1AP33
GS1AP43
GS1APU53
LK3AP63
GS2AP73
LK3AP83

Discount
Schedule

Catalog No.
Standard
Standard
Standard
GS1AXU3
Standard

$ Price
—
—
—
62.00
—

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Dimensions

IEC Style Disconnect Switches, UL 98 Listed
Refer to Catalog 9421CT0311

www.schneider-electric.us

GS1DDU3, 30 A Compact Class CC Fuses
1.83 "

3 34 "

Door Drilling
1 8

96.5

"

2 ø 4.5
19
32

37.3

15

2 12 "

"

11 4 "

65

-OFF

63

2.48"

2"

ø 31
50

1 15
32 "

1"

25.6

45

1 25
32 "

79.5

3 18 "

116

1.72

1.10

1.57

43.9

28

40

ON

FIX

4 169 "

90

-ON

TEST

18.3

23
32

"

2.75

FIX

ø

90°

70

3"
16

Ø 0.27 (4)
7
Ø 1.22
31

65°

OFF

3 14 "
83.8

M5

GS2AH/AHT110, 120, 410 or 420

GS1DU3, 30 A Compact Class J Fuses
4.13

1.83
46.5

105.5
.059
15

2.48
63

-OFF

90

3.38
84

116

2.0
50

1.25
ø 31

1.0
28

1.47
37.3

4.56

Door Drilling
0.13
2 ø 4.5

2.5
65

GS1AH101
or 102

-ON

28

40

43.9

FIX

1.10

1.57

1.72
ON

15.8

0.63

TEST
90°

3.88
99

FIX ø 0.19

2.75

65°

Ø 0.27 (4)
7
Ø 1.22
31

OFF

70

GS2AH/AHT110, 120, 410 or 420

GS2EEU3, 30 A Class CC Fuses
1.72

5.69

43.9

144

1.13 Fix
29

1.10

1.57
5.88

ON

149

2.63
67

TEST

2.75
70

90°

2.44
62

28

40

Fix 5.25
133

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Door Drilling

3.88
99

65°

OFF

Ø 0.27 (4)
7
Ø 1.22
31

Mounting Hole Dimension
0.19 in. (4.8 mm)

8

GS2 AH / AHT 110, 120, 410 or 420

© 2009 Schneider Electric
All Rights Reserved

8-9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Dimensions

GS1 Fusible and LK3 Non-Fusible Disconnect Switches
Refer to Catalog 9421CT0301
www.schneider-electric.us

GS2EU3/GS2GU3, GS2 30 A/60 A Class J Fuse Clips
1.72
43.9

5.63
143

1.50

3.50

38

Door Drilling

89

5.88

ON
TEST

2.75

67

28

40

149

2.63

1.10

1.57

Fix 5.25
133

Ø 0.27 (4)
7

70

90°

Ø 1.22

65°

31

OFF

2.75
70

Mounting Hole Dimension: 0.19 in. (4.8 mm)

6.75
171

GS2JU3, GS2 100 A Class J Fuses
1.72
43.9

5.63

2.06

143

Terminal Lugs 2/0 Max.

Door Drilling

3.44

52

.25

87

Fix 6.56
167

7.19
183

3.31

40

.63
TEST

16

.88
Ø 0.27 (4) 22

70

.75

7

90°

3.31
8.25

28

ON
2.75

84

Ø6.9

1.10

1.57

84

19

Ø 1.22
31

65°

OFF

Mounting Hole Dimension: 0.19 in. (4.8 mm)

210

GS2MU3, GS2 200 A Class J Fuses
1.75
44.6

6.00
152

Fix 2.44
62

3.44

Terminal Lugs 3/0 Max.

Door Drilling

87

8.13

ST

3.75
95

11
Ø11.6

28

40

TE

ON

207

.44

1.10

1.57

Fix 7.50
191

Ø 0.27 (4)
7

4.95

125.1

90°

Ø 1.22
31

65

1.00
25

1.13

1.50

29

38

3.69
94

OFF

9.44
240

Mounting Hole Dimension: 0.19 in. (4.8 mm)

GS2QU3, GS2 400 A Class J Fuses
5.56

2.81

Fix 2.81
72

1.75

72

141

44.6

3.44

Terminal Lugs
2 x 600 MCM Max.

Door Drilling

87

.38

363

ST

4.44
Ø .25
6

11.94
303

28

40

TE

ON
112

1.10

1.57

Fix 8.81
224

14.31

3.13

Ø 0.27 (4)

4.95

80

1.50
38

7

125.1

90°

Ø 1.22
31

65

2.06
52

10
Ø 10.2

2.88
73

OFF
Mounting Hole Dimension: 0.25 in. (6.3 mm)

8

GS2SU3/GS2TU3, GS2 600 A Class J AND 800 A Class L Fuses

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Ø 9.38
2.50
64

Fix 13.63
346
Fix 9.88
251

1.50
38

3.13
80

7.13

4.13
.25 106

4.75 4.75
120 120

64

7.50

.50 190

4.00

13

100

3.13 1.50
3.56
38

1.56

2.88

3.00

80

20.38
517

Ø 0.27 (4)
7

2.50

8.26

209.8
59

Drilling

Terminal Lugs
2X600 MCM Max. 3X600 MCM Max.
Ø 44
Ø .38
2.75
11
10
69

362

2.38

Ø 1.22
31

7

Locking
55°

9.88
250 6.00
14.25 152

492

28

40

181

19.38

1.10 Door

1.57

2.40
61.1

91

73

40

76

Mounting Hole Dimension: 0.38 in. (9.6 mm)

8-10

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Dimensions

GS1 Fusible and LK3 Non-Fusible Disconnect Switches
Refer to Catalog 9421CT0301

www.schneider-electric.us

LK3DU3, Compact LK3 30 A
2.59

3.78

66

96

1.00

.59

1.94

15

37

19

1.00
25

25

.75

Door Drilling

.13

2.00

2 Ø 4.5

1.83

51

46

4.56

116
1.78
Fix 3.13 45
80

1.25

3.84

0-OFF

Ø 31

98

.56
14

90°
-ON

2.48

.72

63

Fix Ø .19
M5

18

Mounting Hole Dimension: 0.19 in. (4.8 mm)

LK3GU3/LK3JU3, LK3 60 A/100 A
1.72
43.9

3.88
99

Ø .19
5

3.50

Fix 1.50
38

Door Drilling

89

1.10

1.57
149

28

40

Fix 5.25
133

5.88

ON

2.63

TEST

2.75

67

Ø 0.27 (4)
7

70

90°

Ø 1.22
31

65°

OFF

2.75
70

6.69

Mounting Hole Dimension: 0.19 in. (4.8 mm)

170

LK3MU3, LK3 200 A
Mounting Hole Dimension: 0.19 in. (4.8 mm)

1.75
44.6

2.44

Ø .19
5

3.44
87

62

Door Drilling

Terminal Lugs 3/0 Max.

.44

Fix 7.50
191

8.13

TE

ON

3.75
95

28

40

206

ST

Ø 0.27 (4)
7

4.95

125.1

1.50
38

1.00
25

1.13
29

Ø 1.22
31

90°

3.69

11
Ø11.6

1.10

1.57

65

94

9.50
241

OFF

LK3QU3/LK3SU3, LK3 400 A/600 A
Terminal Lugs
2 x 600 MCM Max.

6.56
166

3.13

1.56

.38

1.63

5.00

Fix 12.63
320

127

10
Ø 10.2

Door Drilling

41

80

40

1.10

1.57

28

40

Fix 6.88
175

2.31

3.13
80

59

Ø 1.22
31

8.26

20

2.88

.56
14

11.00

38

Ø 0.27 (4)
7

209.8

.81

1.50

73
Fix 10.06
255

279

2.40

Mounting Hole Dimension: 0.25 in. (6.3 mm)

61.1

Door Drilling

1.57

6.56
6.81
2.50

173

166

4.75

40

121

64

Ø 1.22
Ø 0.27 (4)
31
7
Terminal Lugs
2X600 MCM Max. 3X600 MCM Max.
Ø 44
Ø .38
11
10

13.00
330

Fix 6.88
175

2.31
.81 59
20

8.26

.81
20

14.63
372

2.50

209.8

1.56
40

1.10
28

40

1.56

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

LK3TU3/LK3UU3/LK3WU3, LK3 800 A/1000 A/1250 A

64

Fix 13.69
347

3.13
80

1.50 3.56
38

1.56

2.88

3.00

91

40

2.40
61.1

73

76

8

Mounting Hole Dimension: 0.38 in. (9.6 mm)

© 2009 Schneider Electric
All Rights Reserved

8-11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

NEMA Style Disconnect
Switches

NEMA Style Door Mounted Disconnect Switches
Refer to Catalog 9420CT9701
www.schneider-electric.us

File D10
The D10 disconnect switch features high I2T rating, longer contact life, visible contact indication, fuse-mounting flexibility, dead-front construction,
and auxiliary interlocks.
A complete installation includes a D10 disconnect switch, D11 handle operator, and D12 fuse clip kit. The D10 accepts Class H, K, J, or R fuses or
can be used for non-fusible applications. The D10 disconnect switch is operated by a cast metal handle operator that is lockable in the “OFF”
position and defeatable in the “ON” position.
Table 8.40:

Disconnect Switches (without fuse
clips or shorting straps)

Table 8.44:

Max. Horsepower Ratinga
Rating
(A)

120 V

200–
240 V

480 V

30
60
100
200

5
10
15
25

10
20
30
50

20
40
60
100

600 V

Catalog
Number

$ Price

25
50
75
100

D10S1
D10S2
D10S3
D10S4

270.00
292.00
452.00
860.00

a

B F

Complete Kit with
30, 60,
Handle, Shaft, and 100,
200
Actuator

A E
Centerline
of Switch
Operating
Shaft
I
J
D
C

Catalog
Number

$ Price

D10S1H
D10S2H
D10S3H
D10S4H

320.00
352.00
544.00
1154.00

Rotary Handle Operator Kits and Shafts

Rating
(A)

30, 60,
100, 200

Shaft only

Table 8.42:

Enclosure Interior
Depth—Inches
5–6
6–10
10–16
6
12

Catalog
Number
D11SF4
D11SF10
D11SF16
D11SH10
D11SH16

$ Price
106.00
118.00
130.00
26.20
32.80

Auxiliary Electrical Interlock

(for mounting on 30 A—200 A disconnect switch a)
Block Description
(with switch contacts open)
1 N.O.
1 N.C.
1 N.O. and 1 N.C.
2 N.O.
2 N.O. and 2 N.C.
a
One block per switch.

Table 8.43:

Catalog
Number

$ Price

D11N0
D11NC
D11N0C
D11N00
D11N0C2

79.00
79.00
116.00
116.00
130.00

Interrupting and Withstandability
Ratings

Interrupting Rating
Withstandability I2T
Amperes Symmetrical
(Amperes2 seconds)
600 Vac, 3Ø
30
1,200
0.38 x 106
60
1,800
1.28 x 106
100
2.000
2.62 x 106
200
3,600
5.25 x 106
Note: These switches are for motor circuit applications.
Rating (A)

8
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Table 8.46:

Cu
Cu
Al–Cu
Al–Cu

Fuse Clip Kits

Switch Dimensions (in inches)
Length

Width

Mounting Hole Dimensions

Depth

Rating
(A)

A

B

C

D

E

F

G

H

I

J

Ka

lb

30

7-5/16

4-15/32

5-7/8

3-15/32

6

3-15/32

1-7/8

13/32

5-7/16

3-1/4

4-3/32

4-11/32

60

7-5/16

4-15/32

5-7/8

3-15/32

6

3-15/32

1-7/8

13/32

5-7/16

3-1/4

4-11/32

4-11/32

100

9-27/32

5-11/32

8-3/16

4-5/8

5-13/16

3-13/16

2-11/16

51/64

7-5/16

4-3/16

5-23/32

4-27/32

12-3/16

7-7/32

8-3/16

4-5/8

5-13/16

3-13/16

2-11/16

51/64

7-5/16

4-3/16

5-23/32

4-27/32

200
a
b

8-12

Wire Type

#14–#8
#14–#4
#14–#1/0
#6–250 kcmil

Fuse Clip Rating a
Catalog
$ Price
Number
Amperes
AC Volts
Type
No Fuse
D12C01
8.30
16.30
0–30
250
H, K
D12C21
0–30
250
R
D12CR21
65.00
24.50
0–30
600
H, K
D12C61
0–30
600
R
D12CR61
65.00
30 A
0–30
600
J
D12CJ1
49.30
31–60
250
H, K
D12C22
24.50
31–60
600
H, K
D12C62
49.30
31–60
600
R
D12CR62
82.50
31–60
600
J
D12CJ2
57.50
61–100
250
H, K
D12C23
65.00
No Fuse
D12D02
24.50
0–30
250
R
D12DR21
65.00
0–30
600
H, K
D12D61
24.50
0–30
600
R
D12DR61
65.00
31–60
250
H, K
D12D22
23.80
31–60
250
R
D12DR22
82.50
60 A
31–60
600
H, K
D12D62
41.00
31–60
600
R
D12DR62
82.50
31–60
600
J
D12DJ2
57.50
61–100
250
H, K
D12D23
65.00
61–100
600
H, K
D12D63
115.00
61–100
600
J
D12DJ3
106.30
61–100
600
R
D12DR63
113.80
No Fuse
D12E03
49.30
31–60
250
H, K
D12E22
41.00
31–60
600
H, K
D12E62
41.00
61–100
250
H, K
D12E23
32.50
61–100
250
R
D12ER23
115.00
100 A
61–100
600
H, K
D12F63
90.00
61–100
600
R
D12FR63
115.00
61–100
600
J
D12EJ3
115.00
101–200
250
H, K
D12F24
106.30
101–200
600
H, K
D12F64
122.50
101–200
600
J
D12FJ4
140.00
No Fuse
D12F04
82.50
61–100
600
H, K
D12F63
90.00
101–200
250
H, K
D12F24
106.30
200 A
101–200
250
R
D12FR24
140.00
101–200
600
H, K
D12F64
122.50
101–200
600
R
D12FR64
135.00
101–200
600
J
D12FJ4
140.00
a
Continuous current should not exceed switch rating (size). Fuse clip
kits should be sized to accommodate inrush.

Kits include: Handle, shaft, and actuator
NEMA Type 1, 3, 3R, 4, and 12
Description

G
H

Wire Range a

D10
Switch Size

Starter
Max. Horsepower Rating a
NEMA
Rating
200– 480 V 600 V
Type
(A)
120 V 240
V
Size
0–1
30
5
10
20
25
2
60
10
20
40
50
3
100
15
30
60
75
4
200
25
50
100
100
a
Non-fused ratings

Table 8.41:

30
60
1
100
200
One conductor per lug.

Table 8.45:

600 V—With Service Entrance Rating

Line Shield

Number
Per Pole

Rating (A)

600 V—Without Service Entrance Rating
Starter
NEMA
Type
Size
0–1
2
3
4

Lug Data

Maximum depth with largest fuse.
Depth including insulating barrier on service entrance switches.

CP1

Discount
Schedule

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

NEMA Style Disconnect
Switches

Door-Mounted Operating Mechanisms for Square D Circuit Breakers
Class 9421 / Refer to Catalog 9420CT9701

www.schneider-electric.us

Type L Circuit Breaker Mechanisms
Type L door-mounted, variable depth operating mechanisms feature heavy duty, all metal construction with trip
indication. All can be padlocked in the “OFF” position when the enclosure door is open. Further, the handle assemblies
can be locked “OFF” with up to three padlocks, which also locks when the door is closed. (The 3” handle accepts one
padlock.) Complete kits are rated for NEMA Type 1, 3R, and 12 enclosures. They include a handle assembly, operating
mechanism, and shaft assembly.
Table 8.47:

Complete Kits

Complete Kit
Does Not Include Circuit Breaker

Includes:
Operating Mechanism
Standard 6 in. Handle
Standard Shaft Kit

Use With
Circuit Breaker or
Interrupter Type

Frame
Size
(A)

Type

Mounting
$ Price Depth a
Min. – Max.

Type

Mounting
$ Price Depth a
Min. – Max.

Type

Mounting
$ Price Depth a
Min. – Max.

3

75, 100

LG1

140.00

5-1/2–10-1/4

LG4

158.00

5-1/2–20-7/8

LG3

198.00 5-1/2–20-7/8

FAL, FCL, FHL

2–3

100

LN1

140.00

5-1/2–10-7/16

LN4

158.00

5-1/2–21

LN3

198.00

KAL, KCL, KHL

2–3

250

LP1

171.00

6-1/4–11-3/16

LP4

189.00

6-1/4–21-3/4

LP3

230.00 6-1/4–21-3/4

NSF, PowerPact® H and J

2–3

250

LJ1

171.00

5-1/2–10-3/4

LJ4

189.00

5-1/2–21-3/8

—

LALc, LHLc, Q4L

2–3

400

LR1

242.00

6-5/16–10-7/8

LR4

255.00

6-5/16–21-1/2

MEL, MXL

2–3

800

LT1b

242.00

7-3/16–11-5/8

LT4b

255.00

7-3/16–22-1/4

MAL, MHL

2–3

1200

LT1b

242.00

7-3/16–11-5/8

LT4b

255.00

7-3/16–22-1/4

NAL, NCL, NEL, NXL

2–3

1200

LX1b

242.00

8-1/4–12-3/4

LX4b

255.00

8-1/4–23-3/8

PowerPact M and P e

3

1200

LW1d

242.00

7-3/16–11-5/8

LW4d

255.00

7-3/16–22-1/4

5-1/2–21

—

—

3 in. handles are not recommended
for use with these circuit breakers.

Component Parts
3 in. Handle Standard Handle
Assemblies
Assemblies
Type 1, 3R, 12 Type 1, 3R, 12

Use With

Circuit Breaker or
Interrupter Type
GJL

No.
of
Poles

Frame
Size
(A)

Type $ Price Type

Operating
Mechanism
Includes
Lockout

$ Price Type

Standard Shaft
(Support Bracket Not
Required)

Mounting
$ Price Depth a
Min. – Max.

Long Shaft
(Support Bracket Included)

Mounting
Type $ Price Depth a
Min. – Max.

Type $ Price

3

75, 100

LH3

90.00

LH6

50.00

LG7

68.00 5-1/2–10-7/16

LS8

21.50

5-1/2–21

LS13

35.60

FAL, FCL, FHL

2–3

100

LH3

90.00

LH6

50.00

LF1

71.00 5-1/2–10-7/16

LS8

21.50

5-1/2–21

LS12

35.60

KAL, KCL, KHL

2–3

250

LH3

90.00

LH6

50.00

LK1

105.00 6-1/4–11-3/16

LS8

21.50

6-1/4–21-3/4

LS12

35.60

NSF, PowerPact H and J

2–3

250

LH3

90.00

LH6

50.00

LJ7

105.00 5-1/2–10-1/4

LS8

21.50

5-1/2–21-3/8

LS13

35.60

LALc, LHLc, Q4L

2–3

400

LH6

50.00

LL1

170.00 6-5/16–10-7/8

LS8

21.50 6-5/16–21-1/2

LS10

35.60

MEL, MXL

2–3

800

LH8

50.00

LM1

170.00 7-3/16–11-5/8

LS8

21.50 7-3/16–22-1/4

LS10

35.60

MAL, MHL

2–3

1200

LH8

50.00

LM1

170.00 7-3/16–11-5/8

LS8

21.50 7-3/16–22-1/4

LS10

35.60

NAL, NCL, NEL, NXL

2–3

1200

LH8

50.00

LX7

170.00 8-1/4–12-3/4

LS8

21.50

8-1/4–23-3/8

LS10

35.60

PowerPact M and Pe
3
1200
LHP8
50.00 LW7
170.00 7-3/16–11-5/8 LS8
21.50 7-3/16–22-1/4
a
Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door in inches.
b
Types LT1, LT4, LX1, and LX4 include an 8 in. handle rather than a 6 in. handle.
c
Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix.
d
Type LW1 and LW4 include an 8 in. handle (9421LHP8) rather than a 6 in. handle.
e
These circuit breakers must use the 9421LHP** or LCP** handles only.

LS10

35.60

Table 8.49:

3 in. handles
are not
recommended
for use with
these circuit
breakers.

NEMA Type 4 and 4X Handle Assemblies a
Use With

Standard Handle Assemblies
NEMA Type 1, 3R,
4, 12
(Painted)

Special 3 in. Version

NEMA Type 1, 3R,
4, 4X, 12
(Chrome Plated)

NEMA Type 1, 3R,
4, 12
(Painted)

NEMA Type 1, 3R,
4, 4X, 12
(Chrome Plated)

No.
of
Poles

Frame
Size
(A)

Type

$ Price

Type

$ Price

Type

$ Price

Type

$ Price

3

75

LH46

90.00

LC46

149.00

LH43

165.00

LC43

233.00

FAL, FCL, FHL

2–3

100

LH46

90.00

LC46

149.00

LH43

165.00

LC43

233.00

KAL, KCL, KHL

2–3

250

LH46

90.00

LC46

149.00

LH43

165.00

LC43

233.00

NSF, PowerPact H and J

2–3

250

LH46

90.00

LC46

149.00

LH43

165.00

LC43

233.00

LAL, LHL, Q4L

2–3

400

LH46

90.00

LC46

149.00

Circuit Breaker or
Interrupter Type
GJL

MEL, MXL

2–3

800

LH48

90.00

LC48

149.00

MAL, MHL

2–3

1000

LH48

90.00

LC48

NAL, NCL, NEL, NXL

2–3

1200

LH48

90.00

LC48

in. handles are not recommended for use
149.00 3
with these circuit breakers.
149.00

PowerPact M and P
3
1200
LHP48
90.00
LCP48
a
Due to gasketing, NEMA Type 3 & 4 handle assemblies are NOT trip indicating.

Table 8.50:

IEC Style Operating Mechanisms

GJL

Color
Red/Yellow

Type
NW3

Black

NW3B

Extension Shafts

Operating Mechanism
Includes Lockout

Type 1, 4, 4X, 12

Circuit Breaker or
Interrupter Type

a

149.00

$ Price
90.00
90.00

Type
LG8

Mounting Depth
$ Price
$71.00

Min.
6-1/8

Max.
10-3/4

Type

$ Price

NS16

28.70

6-1/8

17-7/8

NS336a

35.60

Contains support bracket.

Table 8.51:

Electrical Interlock Kits—Class 9999 a

Description
Class
Type
$ Price
Single Pole Double Throw
9999
R47
131.00
Double Pole Double Throw
9999
R48
221.00
a
Optional accessory for use with 9421L operating mechanisms.
Note: Not used with GJL, NAL, NCL, NEL, NXL, NSF, NSJ, PowerPact® C, D, H, and J circuit breakers; use field-installed circuit breaker interlocks instead.
© 2009 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Table 8.48:

Standard
Handle
Assembly

Includes:
Operating Mechanism
Short 3 in. Handle
Long Shaft Kit

No.
of
Poles

GJL

3 in. Handle
Assembly

Includes:
Operating Mechanism
Standard 6 in. Handle
Long Shaft Kit

8

Operating
Mechanism

8-13

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Dimensions

Door Mounted Operating Mechanisms
Class 9421 / Refer to Catalog 9420CT9701
www.schneider-electric.us

3.50 Min.

1.38

Refer to NEC
Article 430-10
for minimum
dimension from
top mounting hole
to wall or barrier
X to insure adequate
wire bending space.

45

1.18
30
.50
13

35

L

4.72 1.77
45
120

CLHandle
Mechanism

3.94
100

Screw Driver
Interlock Pin
Location

.45

.28 Maximum

12

7 Door Thickness

CLHandle Mechanism

(2) #8-32 Tap

2.38
60

H
Mounting Depth a

Panel drilling for GJL circuit breaker
and operating mechanism

L = Overall shaft length
H = Distance from inside of enclosure door to circuit
breaker mounting surface

Table 8.52:

Shaft Cutting Dimensions

Class

a

Type

Shaft Length
Formula

H = Standard Shaft

H = Long Shaft

Min.
Max.
L = H–2.50
5.50
10.25
9421
LG7, LG1, LG4, LG3
64
140
260
L = H–2.88
5.50
10.44
9421
LF1, LN1, LN3, LN4
73
140
265
L = H–3.63
6.25
11.19
9421
LK1, LP1, LP3, LP4
92
159
284
L= H–3.00
5.5
10.75
9421
LJ1, LJ4, LJ7
76
138
273
L= H–3.13
6.31
10.88
9421
LL1, LR1, LR4
79
160
276
L= H–4.00
7.18
11.63
9421
LM1, LT1, LT4
102
182
295
L= H–5.17
8.25
12.75
9421
LX7, LX1, LX4
131
210
324
L= H–4.89
7.19
11.63
9421
LW1, LW4, LW7
124
183
295
Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door.

3.25 Minimum
83

(Both Sides)

7.00

4.50

2.25

114

Hinge
Point of
Door

1.50
38

57

.75
19

1.63 R
41

1.56
40

178
Minimum to wall or
barrier to insure
adequate wire bending
space to lug surface
when maximum wire
size is used with
standard lugs.
Refer to NEC Article
430-10.
CL Handle
Mechanism

Min.
5.50
140
5.50
140
6.25
159
5.5
138
6.31
160
7.18
182
8.25
210
7.63
183

Max.
20.85
530
21.00
533
21.75
552
21.63
543
21.50
546
22.25
565
23.38
594
22.25
565

3.25 Minimum
83

13.50

(Both Sides)

4.50

2.25

114

Hinge
Point of
Door

1.50
38

57

.75
19

1.81
46

343
Minimum to wall or
barrier to insure
adequate wire bending
space to lug surface
when maximum wire
size is used with
standard lugs.
Refer to NEC Article
430-10.

5.13
7.13
6.00
152

181

CL Handle & Ckt. Bkr. T oggle

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

(4) #8-32 Tap

CL Handle & Ckt. Bkr. T oggle

8

130

1.63 R
41

6.00
152

(4) #10-24 Tap

C30080-120

Panel drilling for FAL, FCL, FHL circuit breaker
and operating mechanism

8-14

Panel drilling for KAL, KCL, KHL circuit breaker
and operating mechanism

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Dimensions

Door Mounted Operating Mechanisms
Class 9421 / Refer to Catalog 9420CT9701

www.schneider-electric.us

6.00 Minimum
152 (Both Sides)
Hinge
6.00
Point
3.00 152
of Door
76

2.00
2.00 51

.88

487
Minimum to wall or
barrier to insure adequate
wire bending space
to lug surface when
maximum wire size
is used with standard lugs.
Refer to NEC Article 430-10.

51

1.00

22

25

CL
Circuit Breaker

4.57

8.00 Minimum
203 (Both Sides)
Hinge
4.50
Point
114
of
Door

19.19

229

51

76

1.50
38

42

(4) 5/16-18 Tap

40

4.937

(4) 1/4-20 Tap

CL
Circuit Breaker

125

3.09
79

(4) 1/4-20 Tap

1.03

.56

41

14

9.25
235

4.68

(4) #12-24 Tap

119

CL Handle

CL Handle

X
Minimum to wall or
barrier to insure
adequate wire bending
space to lug surface
when maximum wire
size is used. Refer to
NEC Article 430-10.

2.00

1.66

1.59

116

1.63R

9.00
3.00

26

A

CL
Handle

2.68

3.50
89

68

.38
.44
11

.38

CL
Handle

B

10

8.00

10

203

.44

6.00

11

152

1.63R

.88

41

7.19

22

183

5.09
10.19

129

259

Panel Drilling for PowerPact® H and J
Circuit Breakers and Operating Mechanism

Panel Drilling for LAL, LHL, and Q4L
Circuit Breakers and Operating Mechanism

Panel Drilling for MAL, MEL, MHL, and MXL
Circuit Breakers and Operating Mechanism

Dimensions = in. (mm)

Circuit Breaker Type

A

B

MAL, MHL

10.69 (272)

14.00 (356)

MEL, MXL

11.47 (291)

14.75 (375)

C

Minimum to wall or barrier to
insure adequate wire bending

MIN.: 8 in. (203 mm)
(both sides)

X space to lug surface when

M

7.83
199

3.92
100

1.70
43

maximum wire size is used.
Refer to NEC Article 430-10.

1200 A: 16.26
413

64

N
(4) 1/4-20 tap

P
(4) #10-32 tap

12.13

Q

241

CL Handle
Mechanism

8.75
222

7.87
200

9.50

800 A: 12.86
327

308

1.63R
41

8.00

R
1200 A:
4.10
104

2.51
64

203

CL
Circuit Breaker

800 A:
2.49
63

8.50
216

R
Panel Drilling for NAL, NCL, NEL, and NXL
Circuit Breaker and Operating Mechanism

5.24
133
10.48
266

8.27
210

3.02
77

Dim. = in.
mm
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

L
9.00 Minimum (Both Sides)
Handle Mechanism
229
15.00
381
Hinge
3.16
7.50
Point
80
191
of Door
5.00
1.66
127
42
(4) 1/4-20 Tap
2.50

8

Panel Drilling for PowerPact® M and P Circuit Breaker
and Operating Mechanism

© 2009 Schneider Electric
All Rights Reserved

8-15

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Disconnect Switches

Flange Mounted, Variable Depth, and Cable Operated
Class 9422 / Refer to Catalog 9420CT9701
www.schneider-electric.us

The Class 9422 Type TCF, TCN, TDF, TDN, TEF, TEN disconnect switches were designed for control panel installations. These switches include common switch profile 30–100 A, interchangeable fuse
clips 30–60 A, and the ability to add fuse clip kits and cable mechanisms. They are compatible with 9422A and 9423, and are UL recognized and CSA certified.

Table 8.53:

Class 9422 Flange Mounted, Variable Depth Disconnect Switches

Variable
Depth
Disconnect
Mtg.
Switch
Range
Size
Min.–Max.
(in.)

Maximum Horsepower Ratings
AC Systems Volts
(Motor Volts)
208 240 480 600
(200) (230) (460) (575)

Fuse Clip Rating
(Amperes) NonInterchangeable Type
For Class H, J, K
or R Fuses Only

Fuse
Type

DC Using
2 Poles
250 V
Max.

250 V
None

30 A

6-5/8–18

7.5

7.5

15

20

5

60 A

6-5/8–18

15

15

30

50

10

100 A

6-5/8–18

25

30

60

75

20

H, K, J, R
None
H, K, J, R
None
H, K, J, R

—
30
60
—
60
—
—
100

200–400 A

Table 8.54:

Switch and Operating
Mechanism Only—
Does Not Include
Handle Mechanism

600 V

Type

Switch for Use With
Cable Operators
ONLY—
Does Not Include
Handle Mechanism or
Cable Operator

$ Price

—
TCN30
329.00
—
TCF30
372.00
30
TCF33
399.00
—
TDN60
386.00
30
TDF60
458.00
60
TDF63
485.00
—
TEN10
570.00
100
TEF10
783.00
See 9422 TF and TG on page 8-17

Switch and Operating Mechanism
and Handle Mechanism—Overpacked
Includes Type A1
Handle Mechanism

Includes Type A2
Handle Mechanism

Type

$ Price

Type

$ Price

Type

$ Price

TCN30C
TCF30C
TCF33C
TDN60C
TDF60C
TDF63C
TEN10C
TEF10C

315.00
359.00
386.00
372.00
444.00
471.00
557.00
770.00

ATCN301
ATCF301
ATCF331
ATDN601
ATDF601
ATDF631
ATEN101
ATEF101

471.00
513.00
543.00
527.00
599.00
629.00
714.00
926.00

ATCN302
ATCF302
ATCF332
ATDN602
ATDF602
ATDF632
ATEN102
ATEF102

585.00
629.00
660.00
642.00
714.00
741.00
827.00
1040.00

Internal Barrier Kits

Provide an additional barrier that helps prevent accidental contact with live parts. Field installed transparent barriers do not restrict visual inspection of the switch. Barriers provide IEC529 IP2X “finger safe”
protection when the door of the enclosed disconnect switch is open. A convenient door allows use of test probes without accessing fuses and replacement of fuses without removing barrier. Barrier must be
used with the skirt kit to enclose a panel mounted type 9422 disconnect.

Catalog No. ab

Safety Switch Application
(F series only)

Description

SS06

Interior barrier for 60 A safety switch, 30 or 60 A 9422 switch

600 Vac–60 A

SS10

Interior barrier for 100 A safety switch or 100 A 9422 switch

600 Vac–100 A

SS0306SK

Skirt kit to enclose 30 or 60 A 9422 switch (requires SS06)

—

SS10SK
Skirt kit to enclose 100 A 9422 switch (requires SS10)
30528-358-50S Interior barrier for 200 A 9422 disconnect switch
30528-369-50S Interior barrier for 400 A 9422 disconnect switch
a
No Class Number is required.
b
For price, use Discount Schedule DE1, not CP1

Table 8.55:
Disconnect
Switch
Size

30 A
60 A

Table 8.56:
Disconnect
Switch
Size

Switch
Type

Fuse
Type

TCF30
TCN30 H, K, J, R
TCF33
TDN60 H, K, J, R

Fuse Clip Rating
(Amperes)
250 V
30

600 V
—

1.41

Line and Load
Fuse Clip Kit
(includes load base
and fuse pullers)
Type
TC30

220.00
260.00
300.00
340.00
272.00
390.00

30

TC33

71.00

60
—

30
60

TC33
TD63

71.00
99.00

Fuse
Type

100 A = 5.75
1.00

Rejection Feature —
Class R Kit b

250 V
30
60
60
—
100

Cat No. a
RFK03
RFK06
RFK06
RFK06H
RFK10

8

Disconnect
Switch Size

1.00

4.50

8.80"

Fuse Clip Rating
(A)
600 V
—
30
30
60
100

A
B
0.30

$ Price
32.69
34.00
34.00
34.00
64.00

1.50*

100A = 5.10"

Class 9999 Electrical Interlocks
Switch Type

Electrical Interlock
Contacts
SPDTa

Type
TC10

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Disconnect
Switch Size

a

D

4.00
5.50
6.20

*0.30 for 100 A
Class J fuses

TCF, TCN
TDF, TDN
30 A
DPDTb
TC20
TEF, TEN
60 A
BTCF,
BTCN
SPDTa
TC11
100 A
BTDF, BTDN
DPDTb
TC21
BTEF, BTEN
a
1 N.C. or 1 N.O. depending on wiring.
b
2 N.C., 2 N.O. or 1 N.O., 1 N.C. depending on wiring.

Table 8.59:

4.00"

30 A
= 3.50
60 A

Class R Fuse Clip Kits
Switch
Type

1.41

$ Price
42.80

60

Table 8.57:

8-16

$ Price b

Class 9422 Replacement/Retrofit Fuse Clip Kits

TCF30
R
TCF33
R
TDF60
R
60 A
TDF63
R
100 A
TEF10
R
a
No Class Number required.
b
For price, use Discount Schedule DE1, not CP1.
30 A

—
—
—

9422 Type T Disconnect
Application
600 Vac–30 A
600 Vac–60 A
600 Vac–100 A
600 Vac–30 A
600 Vac–60 A
600 Vac–100 A
600 Vac–200 A
600 Vac–400 A

$ Price
120.00
239.00
120.00

D = Distance from handle mechanism
mounting surface to disconnect switch
surface. D min. = 6 5/8" D max. = 18"

Table 8.58:
Switch
Type

30 A,
60 A

239.00
100 A

Dimensions

Maximum
Voltage
30 A, 250 V
30 A, 600 V
30 A, 600 V
60 A, 250 V
60 A, 600 V
60 A, 600 V
100 A, 250 V
100 A, 600 V
100 A, 600 V

Fuse Type
Class
H, K, R
H, K, R
J
H, K, R
H, K, R
J
H, K, R
H, K, R
J

Dimension A Dimension B
1.625
4.25
1.625
2.25
4.75
1.625

—

—

3.25
5.25
3.25

Class 9422 Disconnect Switch Cable Operators (must purchase switch separately)
Cable Mechanisms with A1
Handle for Types 1, 3, 3R, 4 and 12

Cable Mechanismsa

Switch Type

Cable Length
Type
36 in.
CFT30
30 A,
TCF, TCN
48 in.
CFT40
60 A,
TDF, TDN
60 in.
CFT50
100 A
TEF, TEN
120 in.
CFT10
Purchase handle mechanism separately (9422, A1, A2, A3 or A4).

CP1

Discount
Schedule

$ Price
273.00
291.00
291.00
333.00

Type
CFT31
—
CFT51
CFT11

$ Price
417.00
—
432.00
476.00

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Disconnect Switches

Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701

www.schneider-electric.us

Ordering Information
The 9422 Type T disconnect switches are designed for variable depth, flange mounting applications. These switches are
fully compatible with 9422 handle operators and 9423 door closing mechanisms. They feature: 200 and 400 A; fusible
(Classes H, K, J, or R fuses) and nonfusible; right or left flange mounting (except 400 A, which mounts only right hand
flange and requires a special enclosure), UL recognized, and CSA certified.
Table 8.60:

Disconnect Switches
Maximum Horsepower Ratingsa

Disconnect
Switch
Size

Variable Depth
Mounting Range
Min.–Max. (in.)

208
(200)

240
(230)

480
(460)

600
(575)

DC
Using
2 Poles
250 V
Max.

40

60

125

150

40

AC Systems Volts (Motor Volts)

Fuse Clip Rating (A)
Non-Interchangeable
Type For Class
H, J, K, or R Fuses Only
250 V

600 V

Non-Fusible
200 A

9.12–19.25b

Switch and Operating Mechanism
and Handle Mechanism—Overpacked

Switch and Operating
Mechanism Only—
Does Not Include
Handle Mechanism

Includes Type A1
Handle Mechanism

Includes Type A2
Handle Mechanism

Type

$ Price

Type

$ Price

Type

$ Price

TF1

1247.00

ATF11

1389.00

ATF21

1503.00

200

200

TF2

1389.00

ATF12

1530.00

ATF22

1646.00

—

400

TF3c

2052.00

ATF13c

2195.00

ATF23c

2307.00
400 A
11.38
Non-Fusible
TG1fg
2672.00
Fixed Depthd
(A5 or A6 Handle)
75
125
250
350
50
For handle selection, see Table 8.62.
400 A
15.87–19e
400
400
TG2fg
3027.00
Adj. Depthd
(A7 or A8 Handle)
a
Refers to rating of switch only.
b
9422 R2, shown on page 8-23, will extend maximum mounting depth 7 inches.
c
Accommodates Class J fuses only.
d
Switches are either fixed-depth or adjustable; the handle will determine installation.
e
In increments of 0.63 inches.
f
Commercially available enclosures may not accept type TG operating mechanisms. Contact enclosure manufacturer for availability of enclosures for use with these switches.
g
Right hand flange mounting only.

Table 8.61:
Class R Fuses
Fusible disconnect switches on this page and page 8-16
will accept Class R fuses as standard. A field installable
rejection kit is available which, when installed, rejects all
but Class R fuses. With the rejection kit and Class R fuses
installed, the switch is UL component recognized for use
on systems with up to 200,000 RMS symmetrical amperes
fault current available.
Switch
Rating
(A)
200
400

ON

5.69
OFF

144

RESET

TF
TG

6 in. a

1.06
6 in. ae
4 in. a
12 in.
(fixed depth) c
12 in.
(adjustable depth)c
10 in. d
a
b
c
d
e

Type A1

200 A
400 A

200 A
400 A

Type

$ Price

9999
9999

SR4
SR5

47.60
107.00

NEMA Type Enclosure
1, 3, 3R, 4 (sheet steel), 12
4, 4X (stainless steel)b
1, 3, 3R, 4 (sheet steel), 12
4, 4X (stainless steel)b
1, 3, 3R, 4 (sheet steel), 12
4, 4X (stainless steel)b
1, 3, 3R, 4 (sheet steel), 12
4 (stainless steel)
1, 3, 3R, 4 (sheet steel), 12
4 (stainless steel)
1, 3, 3R, 4 (sheet steel), 12
4 (stainless steel)

Type
A1
A2
AP1
AP2
A3
A4
A5
A6
A7
A8
A9
A10

$ Price
143.00
257.00
188.00
338.00
143.00
257.00
251.00
320.00
300.00
372.00
158.00
270.00

Enclosure
Flange

89

“On”

6.13 (9422 A1 and A2)

.88
22

156

4.50 (9422 A3 and A4)

114
10.13 (9422 A9 and A10)
257

Stiffener
Bracket

CL of Operating Mechanism
Door Interlock
Hook
Door Interlock
Defeater Screw
Door

2.16
55

9422 A1, A2, A3, A4, A9, and A10 Handles

Use with 30–200 A switches and all circuit breaker mechanisms.
All external metal parts are either stainless steel or a chrome-plated
non-ferrous die casting.
Use with 400 A Type TG1 and TG2 disconnect switches only.
Use with Type D2 remote or dual adapter kit listed on page 8-24.
Use with 9422 RM1 and 9422 CMP only.

Optional accessory for use with disconnect switches listed
on this page.
Table 8.63:
Electrical Interlocks
For Use
On
Switch
Type
TF, ATF
TG

© 2009 Schneider Electric
All Rights Reserved

600 Vac

Class

Table 8.62:
Handle Mechanisms
Handle mechanism kits are used with all disconnect switch
and circuit breaker installations. The kits contain all parts
necessary for mounting the handle to the flange of the
enclosure. The Types A1–A4, A9–A10 are suitable for right
or left hand flange mounting. Two mounting methods are
offered. The Types A5–A8 handles are designed for right
hand mounting only.
Type of Handle

27

250 Vac

30 A, 60 A
100 A
200 A
400 A

3.50 Maximum

Fuse Clip Rating
Type

Wire Size
Minimum–Maximum
#14–#2 Cu, #10–#2 Al
#10–#0 Cu, #6–#0 Al
#6–300 kcmil Cu or Al
#4–500 kcmil Cu

Class

Single Pole
Interlock
Type

9999
9999

R8
R35

$ Price Class
83.00
275.00

9999
9999

CP1

Two Pole
Interlock
Type

$ Price

R9
R36

243.00
521.00

Discount
Schedule

Rod used only on the
variable-depth mechanism.

The type AP1 and AP2 handles are used exclusively on
the PowerPact® M and P Operating Mechanisms, 9422
RM1 and 9422 CMP. The dimensions are identical to
9422 A1.

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

29

Lug Data

Disconnect
Switch Size

8

1.13

Table 8.64:

8-17

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Disconnect Switches

Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701
www.schneider-electric.us

Dimensions
Table 8.65:
Type
TF1

Dimensions (in. / mm) for 200 A Type TF Disconnect Switches

Switch Size
(A)

Fuse Clips

200

None

TF2

200

TF2

200

TF2

200

TF3

200

Class J
200 A 600 V
Class H, K, R
200 A 250 V
Class H, K, R
200 A 600 V
Class J
400 A 600 V

a

Da

A

B

C

13.33
339
13.33
339
13.33
339
13.33
339
13.33
339

9.38
238
9.38
238
9.38
238
9.38
238
9.38
238

1.64
42
1.64
42
1.64
42
1.64
42
1.64
42

Min.–Max.
9.12–19.25
232 489
9.12–19.25
232 489
9.12–19.25
232 489
9.12–19.25
232 489
9.12–19.25
232 489

E

F

2.33
59
2.33
59
2.33
59
2.33
59
2.33
59

8.00
203
8.00
203
8.00
203
8.00
203
8.00
203

G

H

—
0.09
3
0.09
3
0.09
3
0.09
3

J

K

L

M

—

—

—

—

6.50
165
6.50
165
6.50
165
6.50
165
6.50
165

9.53
242

2.77
70
4.14
105
6.64
169
2.77
70

9.44
240
9.44
240
9.44
240
9.44
240
9.44
240

—

14.11
358
15.48
393
17.98
457
18.53
471

—
—
—

—
—
9.53
242

N

P

Q

R

S

T

—

—

—

9.63
245
9.63
245
9.63
245
9.63
245

3.14
80
3.14
80
3.14
80
3.14
80
3.14
80

1.03
26
1.03
26
1.03
26
1.03
26
1.03
26

0.75
19
0.75
19
0.75
19
0.75
19
0.75
19

—
—
—

The dimensions shown may be extended 7” by utilizing 9422 R2 (two required per switch).

L

A
T

R

B
C

K

B = Minimum to wall or
barrier, right or left
hand mounting to
insure adequate wire
bending space to lug
surface when maximum
wire size is used. Refer
to NEC Article 430-10.

E

S

S

F

F

M

N

G

Vertical CL Flange
Mt’d Oper. Mech.

100 A – For (4) 1/4-20 Tap
H
200 A – For (4) 5/16 -18 Tap
B
200 A
100 A
Enclosure Flange
(2) 1/4-20 Tap
Enclosure Door

Q
P

Dt
Distance from outside
of flange to disconnect
switch mounting surface.

8
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

8-18

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Disconnect Switches

Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701

www.schneider-electric.us

Disconnect Switches—400 A Type TG
Outline Dimensions and General Location, 400 A Disconnect Switches Non-Fusible and Non-Interchangeable
Fuse Clip Type Fusible Switches

Table 8.66:

Handle Mechanism—Type A5 through A8
NOTE: Commercially available enclosures may not accept type TG
operating mechanisms. Contact the enclosure manufacturer
for availability of enclosures for use with these switches.
3.75 Max.

1.44

95 "On"

37

Enclosure
Flange

Switch
Type

B

X

TG1, 2

11.28
286

16.06
408

3.00
76

13.00
11.50 330

B

X

292

11.69

Note: B and X = Minimum to wall or
barrier to insure adequate wire
bending space to lug surface
when maximum wire size is
used.
Refer to NEC Article 430.10.

297

1.88
48

4.78
121

1.50
0.75

4.88

38

124

19

24.00
610

0.38
10

4.25

Operating
Link

0.50

108

13

8.50
216

CL of Operating
Handle

CL of Operating
Mechanism
Door Hook

9.88
251

191

23.81
605

Door
(2) 0.34 Dia.
9 Holes

(2) Switch Mtg.
Brackets

Defeater
Guide
for
Class 9423
Type M1 Kit

Figure 2

3.63
92

(2) Mtg. Holes
in Switch Mtg.
Surface

Figure 1

D30064-973 B

Figure 3

Non-fusible and Fusible Switches
*D

5.50
140

1.86

Dimension D = Distance from outside of flange to
disconnect switch mounting surface.

12.14

36

For Type TG1 or TG2 with:
Type A5 or A6 fixed
depth handle mechanism
Type A7 or A8 adjustable
depth handle mechanism
Weld

13.54
1.40

47

In steps of

344

308

D=
D=

11.38
289
15.87
403
0.63
16

15

to

22

B

19
483

C
L of Operating
Mechanism

Note: Copper lugs are standard on all Type TG
disconnect switches.

23.80

25.00

604

24.00

0.86

0.60

635

* D = Mounting depth measured from the switch mounting
surface to the surface of flange.

610

8.38
213
6.97
177
3.97

Weld

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Table 8.67:

7.50

101

Class J Fuse
400 A 600 Volt

8.13
206

Class H, K, R Fuses
400 A 250 Volt
Class H, K, R Fuses
400 A 600 Volt

Figure 4

Enclosure
Provision for (2) 5/16 Mtg. Screws

Figure 5
in.
mm

8

Dim. =

© 2009 Schneider Electric
All Rights Reserved

8-19

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Bracket Mounted
Disconnect Devices

Type T Disconnect Switches
Class 9422 / Refer to Catalog 9420CT9701
www.schneider-electric.us

The Class 9422 Type T disconnect switches listed in the
table below are shipped with the switch and external
handle assembled to a bracket, ready for installation into
the enclosure. A trim plate is provided with each kit to
Table 8.68:

prevent any mounting screws from being accessible from
the front and also to provide an attractive installation.These
switches can be used with Class 9423 door closing
mechanisms.

Bracket Mounted Disconnect Switches
Maximum Horsepower Rating

Disconnect
Switch Size

208
(200)

240
(230)

480
(480)

250
Vdc

600
(600)

Fuse Type

None
30 A

7.5

7.5

15

20

5

H, K, J, R
Ja
None

60 A

15

15

30

Bracketed Mounted Switch
Mechanism
and Handle

Fuse Clip Rating

AC System Volts (Motor Voltage)

50

10

100 A

25

30

60

75

20

200 A

40

60

125

150

40

a
Space saving design—Type J fuses mounted on the non-fused
bracket.
Note: For Lug Data, see 8-17; for Electrical Interlocks, see page 8-16.

H, K, J, R
Ja
None
H, K, J, R
Ja
None
H, K, J, R
J

250 V
(A)
—
30
60
60
—
60
—
—
—
100
100
—
200
—

600 V
(A)
—
—
30
30
—
30
60
60
—
100
100
—
200
400

Catalog No.

$ Price

BTCN30
BTCF30
BTCF33
BTCF32
BTDN60
BTDF60
BTDF63
BTDF62
BTEN10
BTEF10
BTEF11
TFB1
TFB2
TFB3

471.00
543.00
543.00
543.00
527.00
585.00
629.00
629.00
714.00
926.00
926.00
1488.00
1610.00
2264.00

Note: Some enclosures may not accept the listed bracket mounted operating
mechanisms; contact the enclosure manufacturer.

Table 8.69:
Bracket Mounted Operating Mechanisms for Use With Square D® Circuit Breakers
The circuit breaker operating mechanisms listed below are shipped with the external operating handle assembled to a
bracket. Circuit breakers are not included and must be ordered separately. A trim plate is provided with each kit to
prevent any mounting screws from being accessible from the front and also to provide an attractive installation.The
operating handle is Type A1. These switches can be used with Class 9423 door closing mechanisms.
Operating Mechanism
Use With
Circuit Breaker or
Interrupter Type

No. of
Poles

Right Hand
Flange Mounting
Frame Size
(A)

Cat. No.

$ Price

FAL, FHL
2–3
100
BN1
257.00
KAL, KHL
2–3
250
BP1
270.00
LALa, LHLa, Q4L
2–3
400
BR1
543.00
a
Note: These operating mechanisms cannot be used with any LA/LH
circuit breaker with an MB or MT suffix.

Table 8.70:
Electrical Interlock Kits—Class 9999
Optional accessory for use with circuit breaker operating
mechanisms listed to the left and the flexible cable
mechanisms listed below, except GJL.
Description

Class

Type

$ Price

Single Pole, Double Throw
Double Pole, Double Throw

9999
9999

R26
R27

131.00
243.00

Note: Not used with GJL; use field installed circuit breaker interlocks.

Note: Some enclosures may not accept the listed bracket mounted
operating mechanisms; contact the enclosure manufacturer.

Table 8.71:
Type

D
Disconnect
Device

Dimensions
A
in. (mm)

C
in. (mm)

D
in. (mm)

Min. Enclosure Deptha
in. (mm)

Fusible Device
E in. (mm)
—
11.88 (302)
—
20.00b(508)

BTCN, BTDN, BTEN
6.56 (167)
8.00 (203)
BTCF, BTDF, BTEF
9.50 (241) 1.88 (48) 8.56 (217)
10.00 (254)
6.38 (162)
TFB1
11.50 (292)
3.88 (99) 9.50 (241)
12.00 (305)
13.19 (335)
TFB2, TFB3
20.00 (508)
BG1, BN1
8.75 (222)
7.13 (181)
1.13 (29) 6.50 (165)
8.00 (203)
BP1
9.13 (232)
7.38 (187)
a
The minimum enclosure depth is greater than Dimension D since additional space is needed when mounting
the mechanism.
b
Fuses and fuse base assembly do not extend beyond bracket.
Note: Back panel support is recommended for Types TFB1, 2, & 3. Other devices may also require support if the
flange is not sufficiently rigid.

Table 8.72:

8
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Circuit Breaker
Type

Class 9422—Flexible Cable
Mechanisms for Use With Square D
Circuit Breakers
No. of
Poles

Frame Size
(A)

CP1

Discount
Schedule

F

10

C

0.38
10

Disconnect
Device

ON

A E
OFF

0.38
10

Non Fused
and Circuit
Breaker

Fused

(2) 0.38

Dia. Mounting Holes
10
(For back panel support if necessary.)

For use with Square D circuit breakers and Class 9422 A
handle operators. Especially designed for tall, deep
enclosures where placement flexibility is required. See
page 8-21 for dimensions.
Cable Mechanism

Cable Length
Catalog No.
$ Price
36 in.
CGJ30
273.00
48 in.
CGJ40
291.00
GJL
3
100
60 in.
CGJ50
291.00
120 in.
CGJ10
333.00
36 in.
CFA30
273.00
FAL, FHL
2-3
100
60 in.
CFA50
291.00
120 in.
CFA10
333.00
36 in.
CKA30
288.00
KAL, KHL
2-3
250
60 in.
CKA50
305.00
120 in.
CKA10
347.00
36 in.
CLA30
486.00
LALa, LHLa, Q4L
2-3
400
60 in.
CLA50
504.00
120 in.
CLA10
548.00
a
Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix.

8-20

0.38

F
in. (mm)

Cable Mechanisms with A1 Handle
For Types 1, 3, 3R, 4, 12
Catalog No.
CGJ31
CGJ41
CGJ51
CGJ11
CFA31
CFA51
CFA11
CKA31
CKA51
CKA11
CLA31
CLA51
CLA11

$ Price
417.00
432.00
432.00
476.00
417.00
432.00
476.00
431.00
446.00
489.00
630.00
647.00
689.00

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Flexible Cable
Mechanisms

For Circuit Breakers
Class 9422 / Refer to Catalog 9420CT9701

www.schneider-electric.us

X
C

Refer to NEC Article 430-10 for minimum
dimension X from circuit breaker top
mounting hole to wall or barrier to
ensure adequate wire bending space.

1.00

A

25

E

B

4.69
119
9.12

Table 8.73:

Flexible Cable Mechanisms for Use with Schneider Electric® (formerly
Merlin Gerin®) and PowerPact® 3-Pole Circuit Breakers

For use with Class 9422 A handle operators especially designed for tall, deep enclosures
where placement flexibility is required.
Circuit Breaker
Type

No. of
Poles

Cable Mechanism

Frame Size
A

Length

Type

$ Price

36 in.
60 in.
84 in.
120 in.
36 in.
60 in.
120 in.
36 in.
60 in.
120 in.
36 in.
60 in.
120 in.
36 in.
50 in.
120 in.

CSF30
CSF50
CSF70
CSF10
CSF304
CSF504
CSF104
CSJ30
CSJ50
CSJ10
CSJ304
CSJ504
CSJ104
CMP40
CMP50
CMP10

288.00
305.00
323.00
347.00
297.00
314.00
356.00
486.00
504.00
548.00
500.00
516.00
558.00
759.00
785.00
857.00

232

D

MG-NSF
PowerPact
H- and J-Frame

2-3

250

MG-NSF

4

250

MG-NSJ
PowerPact D

3

600

MG-NSJ
PowerPact D

4

600

PowerPact
M- and P-Frame

3

1200

1.44
37

4.25
108

Note: Bend radius in cable must never be less than 6 inches.
Electrical clearances must be maintained between cable
and live electrical parts.

Table 8.74:

Cable Operating Mechanisms for Circuit Breakers—Dimensions
A

Type
CGJ
CFA
CKA
CLA
CSF 3-Pole
CSF 4-Pole
CSJ 3-Pole
CSJ 4-Pole
CMP

Table 8.75:

Class

B

C

D

E

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

3.50
4.26
4.94
6.00
5.85
5.85
4.13
4.13
8.744

89
108
125
152
149
149
105
105
222

5.25
8.50
10.13
11.00
7.97
7.97
9.50
9.50
15.00

133
216
257
279
202
202
241
241
381

2.50
3.75
3.75
3.75
3.50
3.50
3.00
3.00
2.38

63
95
95
95
89
89
76
76
60

3.75
6.75
7.13
10.19
4.84
8.08
7.25
9.03
12.41

95
171
181
259
123
205
183
229
315

5.25
8.50
10.13
11.00
7.97
7.97
9.50
9.50
15.00

133
216
257
279
202
202
241
241
381

Class 9999 Auxiliary Contact Kits for Disconnect Switches and
Circuit Breakers
Type

Disconnect Switches
9422
BTCF, BTCN, BTDF, BTEF, BTEN
9422
TCF, TCN, TDF, TDN, TEF, TEN
9422
TF
Circuit Breaker Operating Mechanisms
9421
LF, LK, LL, LM, LN, LP, LR, LT, LW
9422
RM, RN, RP, RQ, RR, RT
9422
CFA, CKA, CLA, CSF, CMP

SPDT

DPDT

Type

$ Price

Type

$ Price

TC11
TC10
R8

120.00
120.00
87.00

TC21
TC11
R9

239.00
239.00
243.00

R47
R26
R26

131.00
131.00
131.00

R48
R27
R27

221.00
243.00
243.00

NOTE: No external auxiliary contacts are available for the following circuit breakers:
GJL circuit breakers must use internal catalog No. AAC.
PowerPact D circuit breakers must use internal catalog No. AAC.

8

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

For additional variations, contact CIC at 1-888-SQUARE D (1-888-778-2733).

© 2009 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

8-21

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Flexible Cable
Mechanisms

For Circuit Breakers
Class 9422 / Refer to Catalog 9420CT9701
www.schneider-electric.us

Dual Cable Operating Mechanisms for Square D® Circuit Breakers
Dual Cable Operator Mechanisms are designed for use with Square D GJL and
PowerPact® D, H, and J circuit breakers through 600 A frame sizes. The cable mechanisms
allow for a single handle operator, Class 9422A1, to operate both circuit breakers. The
cable mechanism is designed especially for tall, deep enclosures where placement
flexibility is required. There are numerous cable arrangements to choose from to
accommodate many applications.

Features

•
•
•
•
•

Separate cables for each circuit breaker
Rugged metal flange handle operator
Maximized flexibility of circuit breaker placement for existing and new applications
Control panel can be fed from two separate supply voltages (if required)
Dual mechanism allows both separate supply voltages to be controlled by a single
handle to improve security features

Table 8.76:

Dual Cable Operating Mechanisms Selection

Circuit Breaker Type

GJL

PowerPact H & J
MG NSF

PowerPact D
MG NSJ

Table 8.77:

Cable Length
in. / mm
(quantity)
36 in. / 914 mm (2)
48 in. / 1219 mm (2)
60 in. / 1524 mm (2)
120 in. / 3048 mm (2)
36 in. / 914 mm (1)
60 in. / 1524 mm (1)
60 in. / 1524 mm (1)
120 in. / 3048 mm (1)
120 in. / 3048 mm (2)
36 in. / 914 mm (1)
60 in. / 1524 mm (1)
60 in. / 1524 mm (1-CSF 3 pole)
60 in. / 1524 mm (1-CSF 4 pole)
120 in. / 3048 mm (1-CSF) &
120 in. / 3048 mm (1-CSJ)
36 in. / 914 mm (1-CSF) &
36 in. / 914 mm (1-CSJ)
60 in. / 1524 mm (1-CSF)
60 in. / 1524 mm (1-CSJ)

Catalog
Number
9422CGJD3
9422CGJD4
9422CGJD5
9422CGJD1

Frame Size
(max.)

$ Price

100 A

585.00
608.00
675.00
788.00

9422CGJD8

642.00

9422CGJD9

720.00

9422CSFD1

693.00

9422CSFD35

250 A

9422CSFD345

672.00

9422CSFJD10
9422CSFJD30

648.00

894.00
250 A &
600 A

9422CSFJD50

774.00
809.00

Special Left-hand Mounted Single Cable Operating Mechanisms

Circuit Breaker Type

FAL

Cable Length
in. / mm
(quantity)
120 in. / 3048 mm (1)
36 in. / 914 mm (1)
60 in. / 1524 mm (1)

Catalog
Number

Frame Size
(max.)

$ Price

9422CFAL10
9422CFAL30
9422CFAL50

100 A

350.00
287.00
318.00

8
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

8-22

CP1

Discount
Schedule

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Disconnect Switch
Accessories

Flange Mounted, Variable Depth
Class 9422 / Refer to Catalog 9420CT9701

www.schneider-electric.us

Designed for installation in custom built control enclosures where main or branch circuit protective devices are required. All
circuit breaker operating mechanisms are suitable for either right- or left-hand flange mounting, convertible on the job.
Table 8.78:

Variable Depth Mechanisms for Use with Square D® and Schneider Electric® (formerly
Merlin Gerin®) Circuit Breakers
Use with

Circuit Breaker
Frame Size

No. of
Poles

Operating Mechanism
Variable Depth Mtg.
Range Min.-Max.a
(Inches)

Frame Size
A

Operating Mechanism
Only—Does Not Include
Handle Mechanism

Operating Mechanism and Handle Mechanism
Includes Type A1
Handle Mechanism

Includes Type A2
Handle Mechanism

Type

$ Price

Type

$ Price

Type

$ Price

RG1
RN1
RP1
RR1
RT1
RT1
RX1

116.00
116.00
129.00
329.00
449.00
449.00
513.00

ARG11
ARN11
ARP11
ARR11
ART11
ART11
—

257.00
257.00
270.00
471.00
593.00
593.00
—

ARG21
ARN21
ARP21
ARR21
ART21
ART21
—

372.00
372.00
386.00
585.00
705.00
705.00
—

Square D Circuit Breakers
GJL
FAL, FHL
KAL, KHL
LALc, LHLc, Q4L
MEL, MXL
MAL, MHL
NAL, NCL, NEL, NXL

3
2–3
2–3
2–3
2–3
2–3
2–3

100
100
250
400
800
1200
1200

6.00–17.75
5.38–17.75
6.38–17.88
7.44–18.25
9.00–18.38
9.00–18.38
11.00–18.37

Schneider Electric (formerly Merlin Gerin) and PowerPact® Frame 3-Pole Circuit Breakers
MG-NSF
PowerPact
2–3
250
5.88–17.75
RQ1
185.00
H- and J-Frame
MG-NSJ
3
600
9.00–17.75
RS1
383.00
PowerPact D
PowerPact
3
1200
9.00–18.38
RM1
513.00
M- and P-Frame
a
Class 9422 Type R2 will extend mounting depth 7 inches (see page 8-24).

—

—

—

—

—

—

—

—

—

—

Electrical Interlocks—Class 9999

Description
Class
Single Pole, Double Throw
9999
Double Pole, Double Throw
9999
a
Not for use with the GJL operating mechanism.

Table 8.80:

—

Type
R26a
R27a

$ Price
131.00
243.00

Dimensions

Circuit Breaker
Frame Size

Width
(A)

Type
in.

Height
(B)
mm

in.

mm

Distance to Enclosure Flangea
(C)
Minimum
in.

mm

Maximum
in.

mm

Bracket Depth
(D)
in.

mm

GJL
RG1
5.00
127
4.75
121
6.00
152
17.75
451
4.00
FAL, FHL
RN1
6.75
171
8.50
216
5.51
140
17.75
451
4.26
KAL, KHL
RP1
7.13
181
10.13
257
6.51
165
17.88
454
4.94
LALc, LHLc, Q4L
RR1
10.19
259
11.00
279
7.44
189
18.25
464
6.00
MEL, MXL
RT1
13.38
340
14.00
356
9.00
229
18.38
467
9.69
MAL, MHLb
RT1
13.38
340
14.00
356
9.00
229
18.38
467
9.69
NAL, NCL, NEL, NXL
RX1
19.63
499
13.50
343
11.00
279
18.37
467
9.00
MG-NSF
RQ
4.84
123
7.97
203
5.875
149
17.75
451
5.62
MG-NSJ
RS
9.27
236
9.5
241
9.0
228
17.75
451
5.73
PowerPact M & P
RM
12.29
312
15
381
10.5
267
18.9
480
8.73
a
9422 R2 will extend dimension 7 in. Two required.
b
Minimum mounting depth when using MAL or MHL circuit breakers can be decreased to
7.63 inches by using the Class 9422 Type RT1B conversion kit. $23.00
c
Warning: These operating mechanisms cannot be used with any LA / LH circuit breaker with an MB or MT suffix.

C = Distance from Outside of
Flange to Circuit Breaker
Mounting Surface

Enclosure Door

Enclosure Flange
D

Minimum to wall or barrier.
Right or left hand mounting
to insure adequate wire
bending space to lug
surface when maximum
wire size is used.
Refer to NEC Article
430-10.

B

8

CL
R.H. Handle

A

CL L.H. Handle

102
108
125
152
246
246
229
143
146
222

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Table 8.79:

—

© 2009 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

8-23

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Disconnect Switches

Flange Mounted, Variable Depth Disconnect Switch Accessories
Class 9422 / Refer to Catalog 9420CT9701
www.schneider-electric.us

Remote or Dual Adapter Kit
Switch
or
Breaker

For the remote or dual operation of 30, 60, 100 and 200 A disconnect switches, or GJL, FAL, FHL, KAL, KHL, LAL,
LHL, Q4L, MAL, MHL, MEL and MXL circuit breakers.
Remote Operation—permits mounting the Class 9422 Type A9 or A10 handle mechanism at a lower level than the
disconnect device it controls. This arrangement is often required where the disconnect device is mounted too high for
personnel to easily reach a conventional operator.
Dual Operation—permits controlling two disconnect devices, one in line with and one remote from a single Class 9422
Type A9 or A10 handle mechanism.
NOTE: A Class 9422 Type A9 or A10 handle (page 8-17) and the preferred mounting method must be used.
Table 8.81:

Disconnect Device

Disconnect Device

Remote operation shown
(handle mechanism not
included in kit)

Disconnect Switch
30 A Type TCF/TCN
60 A Type TDF/TDN
100 A Type TEF/TEN
200 A Type TF
Circuit Breaker
GJL
FAL, FHL
KAL, KHL
LAL, LHL, Q4L
MAL, MHL,MEL, MXL

Table 8.82:

Enclosure Mounting
Depth
Min.

Max.

10.63
10.63
12.13
13.13

19.50
19.50
20.25
20.81

10.50
10.66
11.13
12.13
13.75

19.50
19.50
19.50
19.88
20.25

Type

$ Price

D2

251.00

Air Valve Interlock

Note that air valve interlocks only accept the specific three-way air valves, manufactured by Parker, listed in the table below.
Parker Valve Model Numbera
Air Valve Size

Knob Operated
M04841885
M08541848
M04861885
M08561848

0.50 NPT
13

Air valve interlock
mounted on enclosure

a

Alternate Mounting Kit

Channel/Flange Support Kit

Auxiliary Lock Plate

Special Lugs for
Disconnect Switches

8

Operating Rods

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Auxiliary Lock Plate

8-24

$ Price

G1

513.00

Other Accessories

Accessory

Channel/Flange
Support Kit

Type

0.75 NPT
G2
513.00
19
1.00 NPT
M00080004
G1
513.00
25
Prices do not include air valves or handle mechanism. For more information on air valves listed above contact Parker at
C-PARKER@PARKER.COM, or call 1-800-272-7537.

Table 8.83:

Alternate Mounting Kit

Class 9422
Air Valve Interlock

Description
Permits mounting Class 9422 Type A1 or A2 handle mechanisms in
enclosures with flange thickness of 16 gauge to 0.5 in.
Auxiliary kit recommended for use with 30 and 60 A disconnect switches and
FAL, FCL, FHL, KAL KHL, NSF and NSJ circuit breaker mechanisms when
these devices are to be mounted on the center channel of a multi-door
enclosure or when extra rigidity for the flange is required. Supplied as
standard with 100 and 200 A disconnect switches and LAL, LHL, Q4L, MAL,
MHL, MEL and MXL circuit breaker mechanisms.
Auxiliary kit recommended for use with the Class 9422 Type A-1 flange
handle to facilitate padlocking the handle in the “OFF” position. Primarily
used when the handle is mounted on the center channel of a multi-door
enclosure. Also in any case where the enclosure doors interfere with the
normal padlock slot in the flange handle. Meets both the Automotive and
NFPA 79 specifications.
Copper Lugs only—Specify Form Y157
Tin Plated Aluminum Lugs for 400 A Type TG Switch—Specify Form Y1572
(000–750 kcmil Cu/Al wire)
Anderson Type VCEL Compression Lugs—Specify Form Y1574
Exceptions: None of the 30 A or 60 A disconnect switches are available with
compression lugs.
Standard operating rod for use with Class 9422 variable depth mechanisms.
Included as standard in each kit.
Extra long operating rod for use with Class 9422 variable depth mechanisms.
Can be used as a substitute for the standard rod included in each kit to
increase the maximum mounting depth 7 in. (Two are required for Types ARR,
RR, ART, RT, ATE, TE, ATF, TF).

CP1

Discount
Schedule

Class

Type

$ Price

9422

AM2

14.30

9422

C1

42.80

9422

L1

36.00

—

—

No Charge

—

—

No Charge

—

—

No Charge

9422

R1

28.70

9422

R2

50.00

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Door Closing
Mechanisms

Introduction
Class 9423 / Refer to Catalog 9420CT9701

www.schneider-electric.us

Class 9423 door closing mechanisms cover a range of enclosures with up to 91 inch high maximum door openings.
The door closing mechanisms are designed to be used on control enclosures and interlocked with a Class 9422
disconnect device, although they all can be used independently. Three different systems are available and their use is
as recommended below. A complete system is available for interlocking all the doors of a multi-door enclosure with the
master door when using the 6 in. or 8 in. vault handle mechanism.
Note that the “Master Door” is defined to be the door of a single or multi-door enclosure which is interlocked directly
with the disconnect device. The master door can be hinged on either the right or left hand side. It can be located in any
position on a multi-door enclosure. On the other hand, an “Auxiliary Door” is defined to be any remaining doors of a
multi-door enclosure which are interlocked with the master door by means of the overhead interlocking system as
illustrated on pages 8-26 and 8-27.

Selection Procedure
9422 TCN30

Step 1.
Determine enclosure construction (number of doors, door height, hinge location, etc.).
Step 2.
Determine Class 9422 disconnect device to be used—either a disconnect switch or a circuit breaker mechanism.
Step 3.
Determine the location of the disconnect device and handle mechanism (right or left hand flange or center channel).
Step 4.
Select the door closing mechanism required.
Step 5.
Select the auxiliary door closing mechanisms and multi-door interlocking hardware, if required. (A complete system for
interlocking all auxiliary doors of a multi-door enclosure with center channel is available for the medium and large
enclosures.)
Table 8.84:

Door Closing Mechanism

60 in. Maximum Door
Opening
(Recommended)

Circuit Breaker
Mechanism

•
•
•

46–60 in. Door
Opening
(Recommended)

•

2 Point Locking
is Standard
A Third Roller
Latch Kit is
Available for 3
Point Locking
For 3/4 in.
Door Depths

•
•
•

61–91 in. Door
Opening
(Recommended)

•

For use on
Single or
Multi-Door
Enclosures
For use with
Doors Hinged
on Right or Left
Side
Referred to as
the 6 in. Vault
Handle
Mechanism
For 3/4 in.
Door Depths

•
•
•

For use on Single
or Multi-Door
Enclosures
For use with Doors
Hinged on Right or
Left Side
Referred to as the
8 in. Vault Handle
Mechanism
For 1-1/8 in.
Door Depths

Description

Two point, roller latch, door
closing mechanism for use
on enclosures with doors
hinged on the left hand side.

Type M4

Use In
Conjunction
With

NEMA Type 4 and 12
Sheet Steel
NEMA Type 4 and 12
Stainless Steel
NEMA Type 4 and 12
Sheet Steel

Door Latch
Handle
Length

Suggested
Maximum
Door Opening

Door
Depth

Type

$ Price

Class 9422
Types A1, A3, A9

4 in.
4 in.
6 in.

Less than 39 in.
Less than 39 in.
60 in.

a

M4
M10
M9

228.00
314.00
243.00

Class 9422 Types
A2, A4, A10

4 in.

Less than 39 in.

M24

300.00

Class 9422
Types A1, A3, A9

4 in.
4 in.
6 in.

Less than 39 in.
Less than 39 in.
60 in.

M4L
M10L
M9L

228.00
314.00
243.00

4 in.

Less than 39 in.

M24L

300.00

—

—

M3

50.00

—

—

M23

57.00

NEMA Type 4 and 12
Stainless Steel

Class 9422 Types
A2, A4, A10
Class 9423
NEMA Type 4 and 12
Third roller latch kit for 3
Types M4, M9,
Sheet Steel
point locking; for use where
M4L, M9L
3 point locking is desired or
Class 9423
where the door opening is
NEMA Type 4 and 12
Types M24,
39 in. or more.
Stainless Steel
M24L
a
Suitable for door depths of 1-1/8 in., 1-1/4 in., 1-3/8 in. and 1-1/2 in..

a

8

Latch bar not included,
but most prepunched
enclosures that accept
Square D® operating
mechanisms supply a
predrilled latch bar.

Two point, roller latch, door
closing mechanism for use
on enclosures with doors
hinged on the right hand side.

For Use On
(Enclosure Type)

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

The door closing mechanisms listed below are for use on small to medium size single door control enclosures. They
are designed to be used in conjunction with Class 9422 flange mounted disconnect switches and circuit breaker
operating mechanisms; however, they can be used independently as well. When used on properly designed and
gasketed NEMA Type 12 enclosures, they meet NFPA 79 standards.
Table 8.85:
Single Door Enclosures—NEMA Type 4 or 12 with 60 in. High Maximum Opening

© 2009 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

8-25

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Door Closing
Mechanisms

Types M5, M6, M1, and M8
Class 9423 / Refer to Catalog 9420CT9701
www.schneider-electric.us

Vault Type for Single and Multi-Door Enclosures

Table 8.86:

Table 8.86 shows the requirements for the door closing
mechanism, the locking bar kit, and the mechanical
interlock kit, if used.
Single or Multi-Door Enclosures—NEMA Type 12 with 40 in. to 60 in. Door Opening
Single-Door Enclosure

Multi-Door Enclosure

Without Interlocking

With Interlocking

Without Interlocking

With Interlocking

1—M6 door closing mechanism
1—Type M660 locking bar kit

1—M6 door closing mechanism
1—Type M660 locking bar kit
1—Type M5 (use with 9422A handles)

For each door:
1—M6 door closing mechanism
1—Type M660 locking bar kit

For Master door:
1—M6 door closing mechanism
1—Type M660 locking bar kit
1—Type M5 (for use with 9422A handles)

NOTE: All mechanisms listed on this page are
suitable for either left or right hand mounting.

View from Inside the Enclosure

Table 8.87:

1/4" Dia. Rod (Supplied By User)

Locking
Bar

Locking
Bar

A

B
Door
Opening

C

Auxiliary Door

Type M6

Type M5

Door Interlocks

Type M6 Door Closing Mechanism
The Class 9423 Type M6 door closing mechanism is designed
to close and seal 0.75 in. deep doors of single or multi-door
NEMA Type 12 enclosures. The Type M6 can be used on
doors hinged on either the left or right hand side.
Recommended door openings are from 40–60 in. Vault type
handle length is 6 in.
Type M660 Locking Bar Kits
The lock bar kit for the Type M6 door closing mechanism
contains two lock bars and is available from stock. The bars
can be cut to fit door openings through 60 in. One lock bar kit
is required for each Type M6 ordered.
Type M5
The Class 9423 Type M5 mechanical interlock kit is designed
to interlock a Class 9422 handle mechanism with the Type M6
door closing mechanism. This kit prevents opening the master
door (or single door) with the disconnect handle in the “ON”
position, making it mandatory to use a screwdriver to gain entry
to the enclosure at any time, regardless of the disconnect
handle position.

Table 8.88:

Locking
Bar

For each Auxiliary door:
1—M6 door closing mechanism
1—Type M660 locking bar kit
Necessary quantities of Types M2 and
M7 for each door (see below)

257.00

86.00

215.00

Required Accessories for
Auxiliary Doors

Type M2
One Type M2 kit is required for each auxiliary door. This kit is
required to interlock any auxiliary door(s) with the master door.
Type M7
The first auxiliary door requires 2 Type M7 kits. Additional
auxiliary doors require only 1 Type M7 kit. The 0.25 in. diameter
rod used to interconnect the M7 kits is furnished by the user. If
the distance between any two Type M7 kits exceeds 36 in., an
additional Type M7 kit should be installed to prevent the rod
from buckling.

Locking
Bar

$ Price

$ Price
257.00

71.00

Master Door
(Single Door)

Type M7

Type M2

Note: A - Interlocking lever extension of the flange mounted handle
mechanism.
Note: B - Actual enclosure opening—not door height.
Note: C - Screwdriver interlock assembly can be ordered separately.
Class 9423 Type CEQ2493. $45.00

8
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

8-26

CP1

Discount
Schedule

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Door Closing
Mechanisms

For Single and Multi-Door Enclosures
Class 9423 / Refer to Catalog 9420CT9701

www.schneider-electric.us

Vault Type for Single and Multi-Door Enclosures
Table 8.89 shows the requirements for the door closing
mechanism, the locking bar kit, and the mechanical
interlock kit, if used.
Table 8.89:

Single Or Multi-Door Enclosures—NEMA Type 12 with 61 in. to 91 in. Door Openings
Single-Door Enclosure

Without Interlocking
1—M8 door closing mechanism
1—Type M891 locking bar kit

Multi-Door Enclosure

With Interlocking

Without Interlocking

1—M8 door closing mechanism
For each door:
1—Type M891 locking bar kit
1—M8 door closing mechanism
1—Type M1 (for use with 9422A handles) 1—Type M891 locking bar kit

NOTE: All mechanisms listed on this page are suitable
for either left or right hand mounting.

View from Inside the Enclosure

Table 8.90:

1/4" Dia. Rod (supplied by user)

Locking
Bar

Locking
Bar

With Interlocking
For each Auxiliary door:
1—M8 door closing mechanism
1—Type M891 locking bar kit
Necessary quantities of Types M2 and
M7 for each door (see below)

For Master door:
1—M8 door closing mechanism
1—Type M891 locking bar kit
1—Type M1 (for use with 9422A handles)

A

B
Door
Opening

Table 8.91:

Auxiliary Door

Type M8

Type M1

Locking
Bar

$ Price

500.00

86.00

428.00

Required Accessories for
Auxiliary Doors

Type M2
One Type M2 kit is required for each auxiliary door. This kit is
required to interlock any auxiliary door(s) with the master door.
Type M7
The first auxiliary door requires 2 Type M7 kits. Additional
auxiliary doors require only 1 Type M7 kit. The 0.25 in. diameter
rod used to interconnect the M7 kits is furnished by the user. If
the distance between any two Type M7 kits exceeds 36 in., an
additional Type M7 kit should be installed to prevent the rod
from buckling.

C
Locking
Bar

Door Interlocks

Type M8 Door Closing Mechanism
The Class 9423 Type M8 door closing mechanism is designed
to close and seal 1.125 in. deep doors of single or multi-door
NEMA Type 12 enclosures. The Type M8 can be used on doors
hinged on either the left or right hand side. Recommended door
openings are from 61–91 in. Vault type handle length is 8 in.
Type M891 Locking Bar Kits
The lock bar kit for the Type M8 door closing mechanism
contains two lock bars and is available from stock. The bars can
be cut to fit door openings through 91 in.. One lock bar kit is
required for each Type M8 ordered.
Type M1
The Class 9423 Type M1 mechanical interlock kit is designed to
interlock a Class 9422 handle mechanism with the Type M8
door closing mechanism. This kit prevents opening the master
door (or single door) with the disconnect handle in the “ON”
position, making it mandatory to use a screwdriver to gain entry
to the enclosure at any time, regardless of the disconnect
handle position.

$ Price
257.00

71.00

Master Door
(Single Door)

Type M7

Type M2

8

OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

Note: A - Interlocking lever extension of the flange mounted handle
mechanism.
Note: B - Actual enclosure opening—not door height.
Note: C - Screwdriver interlock assembly can be ordered separately.
Class 9423 Type CEQ2493. $45.00

© 2009 Schneider Electric
All Rights Reserved

CP1

Discount
Schedule

8-27

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Door Closing
Mechanisms

Types M5, M6, M1 and M8
Class 9423 / Refer to Catalog 9420CT9701
www.schneider-electric.us

Reference

0.25

2.25 Minimum
57

1.50

6

Enclosure Construction and General Location Information
For Types M5 and M6

38

A
Enclosure Door
Enclosure

B

Door Opening Recommended
40 Inches Minimum
60 Inches Maximum
C

0.2 Dia.

17.69 Minimum

5

0.33 Dia.
8
0.69
18

Flange
Drilling
See Class
9422
Digest
Section

449

33.69 Minimum

1.63

856

41

2.00

0.7 Dia.

2.63

18

67

CL
of Door

0.88 Dia.
22

0.2
5

Dia.
(2 Holes)

Reference

0.50

Disconnect
Device

TCF, TCN, TDF, TDN, TD

If A = 1
Minimum B =

If A = 4½
Minimum B =

C

60 A Disconnect Switch

3-/16

2-1/2

3-3/16

TE, TEF, TEN

100 A Disconnect Switch

5-1/4

2-1/2

3-3/16

TF

200 A Disconnect Switch

11-5/8

8-1/8

3-3/16

TG

400 A Disconnect Switch

15-1/16

11-9/16

6-3/4

RN1

FAL, FHL,
Circuit Breaker

4-27/32

2-1/2

3-3/16

RP1

KAL, KHL
Circuit Breaker

11-5/32

7-21/32

3-3/16

RR2

ILL Circuit Breaker

17-31/32

14-15/32

3-3/16

RT1

MAL, MHL, MEL, MXL
Circuit Breaker

18-5/8

15-1/8

3-3/16

38

Enclosure Door
Enclosure

B

Door Opening Recommended
61 Inches Minimum
91 Inches Maximum
C

0.2 Dia.
5

18

Type

76

A

0.33 Dia.
8
0.69

Dimension B (Minimums)

3.00 Minimum

1.50

13

Single door enclosures: A minimum = 1 in.
Multi-Door enclosures without overhead interlocking system: A minimum = 1 in.
Multi-Door enclosures with overhead interlocking system: A minimum = 4½ in.
Overhead interlocking system consists of the required number of Class 9423 Type M2 and M7 kits for interlocking
the auxiliary doors with the master door. See page 8-26.

Table 8.92:

94

89

Note:
Note:
Note:
Note:

25

71

3.69
3.50

Dimension A

1.00

2.81

51

Drilling and location information below is complete for a single door enclosure with door
hinged on left side, incorporating a Type M6, M5, and Class 9422 handle mechanism.
Transpose all horizontal dimensions for doors hinged on right side.

449

3.75

64

95

1.00
25

4.75
121

89

0.7 Dia.
18

Dimension A

2.25

Note:
Note:
Note:
Note:

57

CL
of Door

+.010
-.000
1.00 Dia.
25

Drilling and location information below is complete for a single door enclosure with the door
hinged on the left side, incorporating a Type M8, M1, and Class 9422 handle mechanism.
Transpose all horizontal dimensions for doors hinged on the right side.

856

48

2.50

Enclosure Construction and General Location Information
For Types M1 and M8

17.69 Minimum
33.69 Minimum

1.88

3.50

Flange
Drilling
See Class
9422
Digest
Section

Single door enclosures: A minimum = 1½ in.
Multi-Door enclosures without overhead interlocking system: A minimum = 1½ in.
Multi-Door enclosures with overhead interlocking system: A minimum = 4½ in.
Overhead interlocking system consists of the required number of Class 9423 Type M2 and M7 kits for interlocking
the auxiliary doors with the master door. See page 8-27.

Table 8.93:
0.2
5

Dia.
(2 Holes)

Dimension B (Minimums)
Disconnect
Device

Type

TCF, TCN, TDF, TDN, TD 60 A Disconnect Switch

8
OPERATOR MECHANISMS AND
DISCONNECT SWITCHES

8-28

If A = 1½
Minimum B =

If A = 4½
Minimum B =

C

2-15/16

2-1/2

3-3/16

TE, TEF, TEN

100 A Disconnect Switch

4-3/4

2-1/2

3-3/16

TF

200 A Disconnect Switch

11-1/8

8-1/8

3-3/16

TG

400 A Disconnect Switch

14-9/16

11-9/16

5-7/8

RN1

FAL, FHL
Circuit Breaker

4-11/32

2-1/2

3-3/16

RP1

KAL, KHL
Circuit Breaker

10-21/32

7-21/32

3-3/16

RR2

ILL Circuit Breaker

17-15/32

14-15/32

3-3/16

RT1

MAL, MHL, MEL, MXL
Circuit Breaker

18-1/8

15-1/8

3-3/16

CP1

Discount
Schedule

© 2009 Schneider Electric
All Rights Reserved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2009:03:04 15:07:16-06:00
Modify Date                     : 2009:07:21 11:45:20-07:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Instance ID                     : uuid:917c3b88-5e42-2142-b87d-db5aa1163295
Document ID                     : adobe:docid:indd:b9f34800-0a58-11de-94b9-c9f90b55436d
Rendition Class                 : proof:pdf
Derived From Instance ID        : d77ef6d0-0342-11de-8b2d-ac93865527c8
Derived From Document ID        : adobe:docid:indd:59304f5e-032f-11de-8b2d-ac93865527c8
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 300.00, 72.00, 72.00
Manifest Placed Y Resolution    : 300.00, 300.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:96E6D313E0F8DD1193D3A206EA549064, uuid:5B665946E0F8DD1193D3A206EA549064, uuid:4FF6EF6A225911DD91B6E1D8435B5599, uuid:4FF6EF6A225911DD91B6E1D8435B5599
Manifest Reference Document ID  : uuid:96CC0F152BCCDD11A7E9FDD05B4D97A8, uuid:4480D645750C11DDA036ECEE5BB6739C, uuid:4FF6EF69225911DD91B6E1D8435B5599, uuid:4FF6EF69225911DD91B6E1D8435B5599
Metadata Date                   : 2009:07:21 11:45:20-07:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10674 bytes, use -b option to extract)
Format                          : application/pdf
Title                           : Schneider Electric DIGEST 175 - Operator Mechanisms and Disconnect Switches
Creator                         : 
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 28
EXIF Metadata provided by EXIF.tools

Navigation menu