Schneider Electric DIGEST 175 Operator Mechanisms And Disconnect Switches
2014-07-05
: Pdf 109266-Attachment 109266-Attachment 785901 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 28
Download | ![]() |
Open PDF In Browser | View PDF |
Table of Contents Section 8 Operator Mechanisms and Disconnect Switches Door-Mounted Switches and Circuit Breaker Mechanisms UL 508 Motor Disconnect Switch (p.8-2 ) Motor Disconnect Switches Mini-Vario and Vario™ 10–115 A 8-2 IEC Style Disconnect Switches GS1/ GS2 / LK3 / LK4 30–1200 A 8-6 NEMA Style Disconnect Switches D10 30–200 A 8-12 Circuit Breaker Mechanisms 9421L 15–1200 A 8-13 UL 98 Fusible Switch (p. 8-6) Flange-Mounted and Cable-Operated Disconnect Switches and Circuit Breaker Mechanisms Disconnect Switches 9422T 30–400 A Disconnect Switches, Bracket Mounted UL 98 NEMA Style Rotary Handle Disconnect Switch (p. 8-12) 9422R Circuit Breaker Mechanism (p. 8-23) 8-16 8-20 Circuit Breaker Cable Mechanisms 9422C Circuit Breaker Mechanisms 9422R 8-22 15–1200 A Accessories 8-23 8-23 Door Closing Mechanisms Single-Door or Multi-Door Closing Mechanisms 9423 Up to 91 in. door openings 8-25 9421L Circuit Breaker Mechanism (p. 8-13) 9423 Door Closing Mechanisms (p. 8-25) OPERATOR MECHANISMS AND DISCONNECT SWITCHES 9422 Circuit Breaker Cable Operator (p. 8-16) 8 UL 508 NEMA Style Flange Handle Disconnect Switch (p. 8-16) © 2009 Schneider Electric All Rights Reserved 8-1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mini-Vario and Vario™ Assembled and Enclosed Switches UL 508 Motor Disconnect Switches Refer to Catalog 9421CT0301 www.schneider-electric.us The Mini-Vario and Vario motor disconnect switch catalog numbers can be identified as described in Table 8.1. Table 8.1: Identification System V CF N12 GE Model (V-Vario, K-Operator) VCFN12GE VN12 Operator Type/ Accessory Designation CD Single hole Red & Yellow CF Four hole Red & Yellow Single hole Red & Yellow w/extension CCD shaft Four hole Red & Yellow w/ extension CCF shaft Blank No operator or accessory Switch Typea Blank N12 Mini-Vario 10/12 A N20 Mini-Vario 16/20 A 02 Vario 10/12 A 01 Vario 16/20 A 0 Vario 20/25 A Enclosure Type (if applicable) Blank No Enclosure Mini-Vario IP55 GE Non-Metallic a BD BF Z Single hole Black & Gray Four hole Black and Gray Switch with Red handle installed on unit (one padlock only) Switch with Black handle installed on unit (no padlock provision) Accessory, power pole, neutral or ground 1 2 3 4 5 6 Vario 20/32 A Vario 25/40 A Vario 45/63 A Vario 63/80 A Vario 100/125 A Vario 115/175 A VE VD G30, A30, W30 Type 1/12/4/4X Metallic (Class 9421) GU Vario IP55 Non-Metallic Switches/contacts are dual rated (UL/IEC). Mini-Vario Table 8.2: Assembled Switches—IP65 VN12/KCC1YZ Red/Yellow (Single Hole) UL/IEC 10/12 A 16/20 A Table 8.3: Catalog Number VCDN12 VCDN20 Black/Gray (Single Hole) $ Price 90.00 135.00 Catalog Number VBDN12 VBDN20 Red/Yellow Mounted In Sealable Enclosure, Non-UL Listed Catalog Number VCFN12GE VCFN20GE $ Price 179.00 189.00 VBDN12 Catalog Number VN12a VN20a VZN12a VZN20a 8 VCDN12 $ Price 90.00 135.00 Table 8.5: Enclosed Switches Complete Switches Mounted in IP55 Non-metallic Enclosure Table 8.4: Complete Switches for Rear Mounting, Includes Extension Shaft (3-Padlock) Complete Switches for Door Mounting (3-Padlock) Current Rating Component Parts Description Catalog Number KCC1YZ KCD1PZ KAD1PZ VZN17 VZN30 KZ32 KZ83 Red/Yellow (Single Hole) Catalog Number VCCDN12 VCCDN20 $ Price 134.00 161.00 Operators and Accessories Description $ Price 45 x 45 mm Red & Yellow operator 60 x 60 mm Red & Yellow operator 60 x 60 mm Black & Gray operator 300–340 mm shaft extension 400–430 mm shaft extension Door interlocking plate for 45 or 60 mm operator Door mounting plate for 45 or 60 mm operator 39.20 39.20 39.20 22.50 27.00 20.30 20.30 $ Price OPERATOR MECHANISMS AND DISCONNECT SWITCHES 10/12 A switch only 16/20 A switch only Add on power pole for 10/12 A switch Add on power pole for 16/20 A switch Neutral Pole with early make, late break for VN12 or VZN11 VN20 switch VZN14 Grounding module for VN12 or VN20 VZN05 N.O. late make auxiliary contactb VZN06 N.C. early break auxiliary contactb VZN26 Single-pole shroud for auxiliary contacts VZN08 Three-pole shroud for VN12 or VN20 a Switches/contacts are dual rated (UL/IEC). b Auxiliary contacts are dual rated (UL/IEC 10/12 A). 52.00 63.00 26.00 31.50 29.30 29.30 27.00 27.00 5.90 7.70 VCCDN20 8-2 CP1 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mini-Vario and Vario™ Switches UL 508 Motor Disconnect Switches Refer to Catalog 9421CT0301 www.schneider-electric.us Vario Table 8.6: NEMA Type 1 and 12 Assembled Switches for Door Mounting Complete Switches (Switch and Handle) for Door Mounting (3-padlock) Operator Style Red/Yellow (Four Hole) Black/Gray (Four Hole) UL/IEC 10/12 A 16/20 A 20/25 A 20/32 A 25/40 A 45/63 A 63/80 A 100/125 A 115/75 A Catalog No. VCF02 VCF01 VCF0 VCF1 VCF2 VCF3 VCF4 VCF5 VCF6 Catalog No. VBF02 VBF01 VBF0 VBF1 VBF2 VBF3 VBF4 VBF5 VBF6 Table 8.7: $ Price 125.00 147.00 174.00 185.00 237.00 282.00 329.00 401.00 612.00 Red/Yellow (Single Hole) Black/Gray (Single Hole) $ Price 125.00 147.00 174.00 185.00 237.00 282.00 329.00 401.00 612.00 Catalog No. VCD02 VCD01 VCD0 VCD1 VCD2 — — — — $ Price 134.00 161.00 206.00 219.00 252.00 — — — — Catalog No. VBD02 VBD01 VBD0 VBD1 VBD2 — — — — $ Price 134.00 161.00 206.00 219.00 252.00 — — — — NEMA Type 1 and 12 Assembled Switches for Rear Mounting Complete Switches for Rear Mounting with Extension Shaft (3-Padlock)a Operator Style Switches with Handles Installed on Unit, DIN Rail Mount Only Red/Yellow (Four Hole) Red/Yellow (Single Hole) Red/Yellow (1-Padlock) Black/Gray (No-Padlock) UL/IEC Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. 10/12 A VCCF02 162.00 VCCD02 162.00 — — — 16/20 A VCCF01 185.00 VCCD01 185.00 — — — 20/25 A VCCF0 197.00 VCCD0 197.00 VVE0 149.00 VVD0 20/32 A VCCF1 206.00 VCCD1 206.00 VVE1 156.00 VVD1 25/40 A VCCF2 252.00 VCCD2 252.00 VVE2 180.00 VVD2 45/63 A VCCF3 320.00 — — VVE3 212.00 VVD3 63/80 A VCCF4 356.00 — — VVE4 300.00 VVD4 100/125 A VCCF5 464.00 — — — — — 115/75 A VCCF6 606.00 — — — — — a Complete switch includes handle operator, shaft, door interlock plate, and line terminal shroud. Metallic Enclosure Non-Metallic Enclosure Metallic Enclosed Switch Dimensions 6.88 Table 8.8: 8 5.38 175 Non-Metallic Enclosed Switches a b IP55-PVC 3-Pole, NEMA Type 1 & 12 Catalog No. $ Price 20/32 VC1GU 239.00 25/40 VC2GU 287.00 45/63 VC3GU 345.00 63/80 VC4GU 381.00 100/125 VC5GU 548.00 115/175 VC6GU 845.00 Assembled, includes switches mounted in enclosure with handle. Refer to Table 8.11 and Table 8.12 for horsepower ratings. Ampere Size UL/IEC .31 137 a b 4.25 5.63 108 143 5.88 149 The V1 and V2 come in metallic enclosures (NEMA Type 1, 4, 4X, and 12). The NEMA Type 1 is supplied with conduit knockouts top and bottom. A VZ7 auxiliary contact can be factory installed in these metallic enclosures by adding Form X11 to the catalog number. A VZ20 auxiliary contact can be factory installed in these enclosures by adding Form X20 to the catalog number. Price Adder $42.00 NEMA Type 1 V1G30, V2G30 3.00 76 Table 8.9: 7.38 6.75 187 171 114 140 6.25 159 NEMA Type 4, 4X, 12 V1W30, V2W30, V1A30, V2A30 Ø 6.2 Table 8.10: 600 V e b VC1GU–VC6GU NEMA Type 1 Catalog No. NEMA Type 12 $ Price Catalog No. $ Price NEMA Type 4/4Xb Catalog No. $ Price Non-Metallic Enclosed Switch Dimensionsa No. of Poles Catalog No. a Table 8.11: d a © 2009 Schneider Electric All Rights Reserved 480 V a in. VC1GU–VC2GU 3 6.7 VC3GU–VC4GU 3 6.7 VC5GU–VC6GU 3 11.0 a UL Rated, NEMA Type 1, 12, IP55. .25 Legend Plate Holder 240 V 20/32 5 10 10 9421V1G30 333.00 9421V1A30 548.00 9421V1W30 783.00 25/40 5 10 15 9421V2G30 381.00 9421V2A30 594.00 9421V2W30 831.00 a Assembled, includes: switches mounted in enclosure with handle. b For indoor use only. The NEMA 4/4X enclosure is made of #304 stainless steel with 3/4 in. T&B stainless steel hubs on the top and bottom. 4.50 5.50 Metallic Enclosed Switches a b Horsepower Ratings Ampere Size UL/IEC f 12 20 25 32 40 63 80 125 175 CP1 mm 170 170 280 in. 4.1 5.3 8.6 mm 105 135 220 in. 3.2 3.3 5.0 Dimensions c d mm in. mm 82 4.8 122 85 5.1 130 126 7.9 201 e in. 2.1 3.7 7.5 f mm 53 95 190 in. 5.0 5.2 8.6 mm 128 131 203 Vario Manual Motor Control Switches, IEC Ampere Size IEC c b Discount Schedule 230 V 3 4 5.5 5.5 7.5 15 18.5 22 30 kW Rating 240 V 400 V 3 4 4 5.5 5.5 7.5 5.5 11 7.5 15 15 22 18.5 30 22 37 30 45 415 V 4 5.5 7.5 11 15 22 30 37 45 3-Pole Switch Body 500 V 690 V 5.5 7.5 7.5 11 11 15 11 15 18.5 15 30 22 37 30 45 37 55 45 OPERATOR MECHANISMS AND DISCONNECT SWITCHES 76 The Vario Motor Disconnect Switch is also offered as an enclosed switch, which is made of corrosion resistant material. The 3-pole version makes the Vario switch ideal for manual motor control applications. They are compact, easy to wire and connect, and come undrilled to allow variable cable entry positions. Note: VCGU enclosures are UL approved. 8 3.00 $ Price — — 149.00 156.00 180.00 212.00 300.00 — — 8-3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com UL 508 Motor Disconnect Switches Mini-Vario and Vario™ Switches Refer to Catalog 9421CT0301 www.schneider-electric.us Table 8.12: Ampere Size UL 10 16 20 20 25 45 63 100 115 Vario Manual Motor Control Switches Vario Manual Motor Control Switches, UL Horsepower Rating 240 V 2 3 5 5 5 10 15 25 30 480 V 5 7.5 10 10 10 20 30 50 50 600 V 5 7.5 10 10 15 30 40 50 60 Shaft Size 3-Pole Switch Body mm 6 6 6 6 6 8 8 8 8 Type V02 V01 V0 V1 V2 V3 V4 V5 V6 Vario switches act as enclosure disconnects when short circuit protection is provided upstream of the switch (if short circuit protection is not provided upstream, use GS1, LK3, Class 9422 Type T or D10 disconnect switches). Type V switches meet UL 508 requirements as manual motor controllers. Table 8.13: Ampere Size UL/IEC NEMA Type 1 and 12 Handle Operators: V02–V2 (6 mm Shaft), V3–V6 (8 mm Shaft) a Red/Yellow Single Hole 45 x 45 mm Operator Type Switches V02–V2 V02–V2 No. of Padlocks 0 1 Catalog No. V02–V2 V3–V4 V02–V2 V3–V4 $ Price Catalog No. $ Price KCE1LZ 39.20 KCE1YZ 39.20 Red/Yellow Four Hole 60 x 60 mm Black/Gray Single Hole 45 x 45 mm Catalog No. $ Price KDD1PZ 39.20 KDF1PZ 39.20 KBD1PZ — — KDF2PZ 39.20 — KCD1PZ 39.20 KCF1PZ 39.20 KAD1PZ — — KCF2PZ 39.20 — Red/Yellow Four Hole Black/Gray Four Hole Operator Type 90 x 90 mm 90 x 90 mm V5–V6 0 KDF3PZ 107.00 KBF3PZ 107.00 V5–V6 3 KCF3PZ 107.00 KAF3PZ 107.00 a When using these handles for replacements on the non-metallic enclosed switches (see page 8-3), the handle shaft supplied with the enclosure must be reused. Switches 39.20 — 39.20 — Red/Yellow Single Hole 60 x 60 mm No. of Padlocks 3 3 Catalog No. Red/Yellow Four Hole 60 x 60 mm $ Price Catalog No. $ Price Black/Gray Single Hole 60 x 60 Catalog No. 39.20 — Catalog No. $ Price KAF1XZ KAF2XZ 39.20 39.20 Description 45 x 45 mm Gasket for V02-V2 for 4-hole type handles (order in quantities of 5)—IP65 60 x 60 mm Gasket for V02-V2 for 4-hole type handles (order in quantities of 5) 60 x 60 mm Gasket for V3-V4 for 4-hole type handles (order in quantities of 5) 90 x 90 mm Gasket for V5-V6 for 4-hole type handles (order in quantities of 5)—IP65 5.5 8 13 5.5 48 12.7 $ Price 5.90 12.00 12.00 15.60 OPERATOR MECHANISMS AND DISCONNECT SWITCHES Single-Hole Mounting Dimensions 13 68 48 22.5 Four-Hole 60 x 60 Mounting Dimensions a Four-Hole 90 x 90 Mounting Dimensions a The door interlock plate included with VCC Kits has the same drilling as the handle operators. Table 8.17: Rear/Panel Mounting Switch Body Dimensions Dimensions Type V02 to V2 V3 to V4 V5 to V6 8-4 39.20 39.20 39.20 39.20 Gasket Kits Catalog No. KZ65 KZ66 KZ62 KZ67 3 Low-Profile Handle KCD1YZ KBF1PZ KBF2PZ KAF1PZ KAF2PZ 68 Table 8.16: a $ Price KAE1BZ 39.20 — — Black/Gray Four Hole 60 x 60 mm Black/Gray Four Hole 60 x 60 mm $ Price KCD1YZ 39.20 KCF1YZ 39.20 KADIXZ — — KCF2YZ 39.20 — Red/Yellow Four Hole Black/Gray Four Hole Operator Type 90 x 90 mm 90 x 90 mm V5–V6 3 KCG2YZ 72.00 KAG2XZ 72.00 a When using these handles for replacements on the non-metallic enclosed switches (see page 8-3), the handle shaft supplied with the enclosure must be reused. Four-Hole Operator KDF3PZ and KBF3PZ Catalog No. Low Profile Handle Operatorsa Operator Type V02–V2 V3–V4 Black/Gray Four Hole 45 x 45 mm KAC1BZ 39.20 — — Black/Gray Single Hole 60 x 60 mm 0 0 3 3 Table 8.15: Four-Hole Operator (All except KDF3PZ and KBF3PZ) Red/Yellow Four Hole 45 x 45 mm KCC1LZ 39.20 KCC1YZ 39.20 Red/Yellow Single Hole 60 x 60 mm Operator Type Single-Hole Operator 3 Pole Switch Body Shaft Size mm Type $ Price 10/12 6 V02 62.00 16/20 6 V01 74.00 20/25 6 V0 84.00 20/32 6 V1 95.00 25/40 6 V2 143.00 45/63 8 V3 179.00 63/80 8 V4 215.00 100/125 8 V5 287.00 115/175 8 V6 428.00 a Refer to Table 8.11 and Table 8.12 for horsepower ratings. Manual Motor Control Switch Table 8.14: Switch Bodya Shaft Extension VZ17 VZ30 VZ18 VZ31 VZ18 VZ31 a in. 5.5–13.0 5.5–16.9 5.5–12.6 5.5–16.5 6.5–13.8 6.5–17.7 1.5-6 b mm 140–330 140–430 140–320 140–420 165–350 165–450 CP1 in. 0.60 c mm in. mm 15 in. dia. d mm 2.4 60 0.17 4.2 60 0.20 5.2 0.79 20 2.4 1.20 30 3.9 100 0.28 7.0 c 1.73 Discount Schedule b d 44 a © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mini-Vario and Vario™ Accessories UL 508 Motor Disconnect Switches Refer to Catalog 9421CT0301 www.schneider-electric.us 13 .217 .512 .217 a 2.68 48 b Door Mounting Switch Body Dimensions Switch Type 68 1.89 44 Table 8.18: Dimensions 2.68 c 1.89 48 1.73 13 5.5 5.5 68 in. 13.0 12.6 13.8 16.9 16.5 17.7 V02 to V2 V3, V4 V5, V6 V02 to V2 V3, V4 V5, V6 Table 8.20: Switch Type V02 to V2 V3, V4 V5, V6 Table 8.21: Shaft Extension Kit a b Shaft Extension Kit mm 330 320 351 429 419 450 Switch Type V02–V2 V3–V4 V5–V6 VZ17 VZ18 VZ18 VZ30 VZ31 VZ31 Line Side Terminal Shroud For Main Switch VZ8 VZ9 VZ10 Terminal Shroud for Main Switch VZ8 20.30 39.20 39.20 20.30 39.20 39.20 Terminal Shroud for Auxiliary Contact VZ29 VZ29 VZ29 $ Price 5.90 5.90 9.50 $ Price 10/12 16/20 20/25 20/32 25/40 45/63 63/80 — — 1 N.O. & 1 N.C. a 2 N.O. VZ7b VZ20b 31.50 32.90 34.20 35.60 55.00 66.00 82.00 — — Grounding Module $ Price 5.90 5.90 5.90 $ Price 42.80 Auxiliary Contacts $ Price Catalog No. $ Price Catalog No. Description $ Price 42.80 VZ14 42.80 VZ7 1 Late Make N.O. & 1 Early Break N.C. 42.80 54.00 VZ15 54.00 VZ20 2 N.O. Contacts 42.80 70.00 VZ16 70.00 — — — Labeling Accessories Nameplate Holder Only $ Price 4.80 4.80 7.80 Catalog No. KZ14 KZ16 KZ101 $ Price 4.40 4.40 6.80 Nameplate Only Use With KZ14 KZ16 KZ1010 Catalog No. KZ76 KZ77 KZ100 $ Price 3.50 3.50 3.50 Shrouds 3-Pole Shroud Table 8.25: KZ83 KZ81 KZ81 KZ83 KZ81 KZ81 Add-On Contact Modules Catalog No. VZ8 VZ9 VZ10 — V02–V2 V3–V4 V5–V6 — 20.30 39.20 39.20 20.30 39.20 39.20 $ Price Auxiliary Contacts Ampere Rating UL/IEC Main Pole Catalog No. KZ13 KZ15 KZ103 Switch Type 0.44 0.44 1.10 2.00 Door Mounting Plate $ Price KZ32 KZ74 KZ74 KZ32 KZ74 KZ74 Terminal Shroud for Add-on Power Pole VZ26 VZ27 VZ28 8.40 8.40 12.00 Nameplate Holder with Nameplate Table 8.24: mm 74 74 83 125 Add-On Contact Modules Catalog No. VZ11 VZ12 VZ13 Size 45 x 45 mm 60 x 60 mm 90 x 90 mm in. 2.91 2.91 3.27 4.92 Door Interlock Plate 28.70 35.60 35.60 35.60 42.80 42.80 $ Price Neutral Modules Early Make/Late Break Table 8.23: Terminal Shroud for Auxiliary Contact VZ29 $ Price V02 VZ02 VZ02 V01 VZ01 VZ01 V0 VZ0 VZ0 V1 VZ1 VZ1 V2 VZ2 VZ2 V3 VZ3 VZ3 V4 VZ4 VZ4 V5 — — V6 — — Early Break, Late Make. Auxiliary contacts are rated UL/IEC 10/12 A. Table 8.22: mm 55 55 60 90 Accessories Main Pole Module Switch Type Weight Approx. lbs. c in. 2.17 2.17 2.36 3.54 Shaft Extension and Door Interlock Maximum Panel Depth Switch Type Add-On Contact Modules b in. mm V02 to V2a 2.83 72 V02 to V2 2.36 60 V3 to V4 2.56 65 V5 to V6 3.54 90 a Dimensions for single-hole mounting. Table 8.19: Door Interlock Plate KZ32 a Single-Pole Shroud $ Price 8.40 8.40 12.00 — For Add-On Power Pole VZ02-VZ2, VZ11 & VZ14 VZ23, VZ4, VZ12 & VZ15 VZ13 & VZ16 For 2-Pole Aux. Contact Catalog No. VZ26 VZ27 VZ28 VZ29 $ Price 5.90 6.90 9.50 5.90 Main Pole Module Dimensions Dimensions b Switch Type c V02 to VZ2 VZ3 to VZ4 in. 0.63 0.79 b mm 16 20 in. 2.9 3.3 Weight Approx. lbs. c mm 74 83 in. 1.38 1.80 mm 35 46 0.10 0.22 8 a a Main Pole Module © 2009 Schneider Electric All Rights Reserved OPERATOR MECHANISMS AND DISCONNECT SWITCHES .512 1.5-6 CP1 Discount Schedule 8-5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Disconnect Switches GS1/GS2 Fusible and LK3/LK4 Non-Fusible, UL 98 Listed Refer to Catalog 9421CT0301 www.schneider-electric.us Identification System The GS1 part numbers can be identified as follows: (See Catalog 9421CT0301 for specific applications.) GS1 D U 3 Model “GS1”, “GS2”—Fusible (Class J Fuse unless noted), “LK3”, “LK4”—Non-Fusible Current Range, Operator Style (Front Operator unless noted), Accessory Type “D”—30 A Front and Side Operation, “DD”—30 A Class CC Front and Side Operation “E”—30 A, “EE”—30 A Class CC, “G”—60 A, “J”—100 A, “M”—200 A, “Q”—400 A, “S”—600 A, “T”—800 A (Class L if Fused), “U”—1000 A, “W”—1200 A UL Certification Poles—Number of Poles 2 or 3 “AH”—Handle, “AHT”—Handle w/ Test, “AE”—Extension Shaft, “AD”—Aux contact holder, “AM”—Aux Contact Note: All fusible switches through 400 A and non-fused switches through 200 A are equipped with a feature to test optional auxiliary contacts without energizing the load when the appropriate GS1AHT*** handle is used. Table 8.26: Catalog Number Table 8.28: Switches — Fusible Description $ Price Compact GS1 Fusible IEC Style Disconnect Switches GS1DDU3 30 A, 3-Pole, Class CC, use 5 x 5 Shaft GS1DU3 30 A, 3-Pole, Class J, use 5 x 5 Shaft 200 A Switch GS2MU3 GS2 Fusible IEC Style Disconnect Switches GS2EEU3 30 A, 3-Pole, Class CC , use 10 x 10 Shaft GS2EU3 30 A, 3-Pole, Class J, use 10 x 10 Shaft GS2GU3 60 A, 3-Pole, Class J, use 10 x 10 Shaft GS2JU3ab 100 A, 3-Pole, Class J, use 10 x 10 Shaft GS2MU3ab 200 A, 3-Pole, Class J, use 10 x 10 Shaft GS2QU3ab 400 A, 3-Pole, Class J, use 10 x 10 Shaft GS2SU3ab 600 A, 3-Pole, Class J, use 15 x 12 Shaft GS2TU3ab 800 A, 3-Pole, Class L, use 15 x 12 Shaft Table 8.27: Catalog Number 30 A Side Handle GS1EERU30 237.00 260.00 237.00 260.00 336.00 536.00 1181.00 2252.00 3378.00 5061.00 Catalog Number Switches — Non-Fusible Description $ Price Compact LK3 Non-Fusible IEC Style Disconnect Switches LK3/LK4DU3 30 A, 3-Pole, 5 x 5 Shaft LK4 Non-Fusible IEC Style Disconnect Switches LK4GU3 60 A, 3-Pole, use 10 x 10 Shaft LK4JU3 100 A, 3-Pole, use 10 x 10 Shaft LK4MU3ab 200 A, 3-Pole, use 10 x 10 Shaft LK4QU3ab 400 A, 3-Pole, use 15 x 15 Shaft LK3SU3ab 600 A, 3-Pole, use 15 x 12 Shaft LK3TU3ab 800 A, 3-Pole, use 15 x 12 Shaft LK3UU3ab 1000 A, 3-Pole, use 15 x 12 Shaft LK3WU3ab 1200 A, 3-Pole, use 15 x 12 Shaft 218.00 263.00 458.00 1010.00 1910.00 2873.00 4301.00 5372.00 6450.00 Switches — Fusible with Direct Mount Side Handle Description $ Price Switches with Direct Mount Side Handle GS1EERU20 30 A, 2-Pole, Class CC 204.00 GS1EERU30 30 A, 3-Pole, Class CC 242.00 Right Side Handle for GS1AH01 46.40 GS1EERU20 & GS1EERU30 a Shipped with line side terminal shrouds, for additional shrouds see page 8-8. b Terminal lug must be ordered separately—see page 8-8. Compact 30 A Switch LK3DU3 Example of the parts to order to build a complete switch: Choose a switch + Shaft + Handle Assembly + Lugs if needed 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES 600 A LK3SU3 8-6 Shaft 200 mm GS2AE5 Black Handle GS2AH150 Lugs Kit GS1AW503 For example: To add auxiliary contacts: LK3SU3 (600 A Non-Fusible Switch, use 15 x 12 Shaft) + GS2AE6 (15 x 12 200 mm Type S Shaft) + GS2AH150 (Black/ Black, Lockable) For front mounted contacts order LK3AD30 (front mounted auxiliary contact holder) + GS2AM110 (N.O. contact for GS1AD10, GS2AD11, and LK3AD30). CP1 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Disconnect Switches GS1/GS2 Fusible and LK3/LK4 Non-Fusible, UL 98 Listed Refer to Catalog 9421CT0301 www.schneider-electric.us Handles Type D Alternate Handles for Compact Switches Only Economical Handle Design Table 8.29: NEMA/UL Type 1, 12 1, 12 Compact Shaft Kits Table 8.30: GS1AH101 GS1AH102 NEMA/UL Type 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 1, 3R, 4, 4X, 12 GS1AE7/AE71 Shafts Type S Standard Handle Design Table 8.31: Use these shaft kits when using Compact Switches NEMA/UL Type GS2AH110 GS2AH120 GS2AE8/AE81 Shafts NEMA/UL Type GS2AH120 IEC Type IP54 IP54 Defeatable Yes Yes Padlockable Yes Yes Color Black Red/Yellow IEC Type IP54 IP54 IP54 IP54 IP65 IP65 IP65 IP65 Defeatable Yes Yes Yes Yes Yes Yes Yes Yes Padlockable Yes Yes Yes Yes Yes Yes Yes Yes Color Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Catalog No. GS1AH101 GS1AH102 $ Price 51.00 51.00 Operation Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Catalog No. GS2AH110 GS2AH120 GS2AHT110 GS2AHT120 GS2AH410 GS2AH420 GS2AHT410 GS2AHT420 $ Price 62.00 62.00 117.00 117.00 70.00 70.00 117.00 117.00 Pistol Handles for Standard GS2 and LK4 (as listed below) IEC Type Defeatable Padlockable Color Operation Catalog No. $ Price Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) GS2AH110 GS2AH120 GS2AHT110 GS2AHT120 GS2AH410 GS2AH420 GS2AHT410 GS2AHT420 62.00 62.00 117.00 117.00 70.00 70.00 117.00 117.00 Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) Off/On (O/I) Off/On (O/I) Test/Off/On (T/O/I) Test/Off/On (T/O/I) GS2AH130 GS2AH140 GS2AHT130 GS2AHT140 GS2AH430 GS2AH440 GS2AHT430 GS2AHT440 70.00 70.00 125.00 125.00 78.00 78.00 132.00 132.00 Pistol Handles for Use with Shaft Type S (as listed below) IEC Type Defeatable Padlockable Color For LK3 400–1200 A 1, 3R, 4, 4X, 12 IP65 Yes Yes Black 1, 3R, 4, 4X, 12 IP65 Yes Yes Red/Yellow For GS2 600–800 A 1, 3R, 4, 4X, 12 IP65 Yes Yes Black 1, 3R, 4, 4X, 12 IP65 Yes Yes Red/Yellow Note: Now UL approved for indoor or outdoor applications. Table 8.33: Operation Off/On (O/I) Off/On (O/I) Pistol Handles for Compact and Standard GS1/GS2 and LK3/LK4 for Compact GS1, 30 A, and Compact LK3 30 A (3 in. handles) for Use with Shaft Type S (as listed below) GS2 30–100 A and LK4 60–100 A (3 in. handles) 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes GS2 200–400 A and LK4 200 A (5 in. handles) 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 12 IP54 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes 1, 3R, 4, 4X, 12 IP65 Yes Yes Table 8.32: GS2AH110 Pistol Handles for Compact GS1 and LK3 for Use with Shaft Type D (as listed below) Operation Catalog No. $ Price Off/On (O/I) Off/On (O/I) GS2AH150 GS2AH160 263.00 263.00 Off/On (O/I) Off/On (O/I) GS2AH150 GS2AH160 263.00 263.00 Shafts Length in. mm Catalog No. $ Price Shaft 5 mm x 5 mm—for Use with Pistol Handles, Type D 12.6 15.7 320 400 GS1AE7 GS1AE71 18.60 23.30 GS2AE8 GS2AE81 18.60 23.30 GS2AE2 GS2AE21 20.30 25.00 GS2AE5 GS2AE51 32.60 40.40 GS2AE5 / AE51 12.6 15.7 320 400 Shaft 10 mm x 10 mm—for Use with Standard GS2 and LK4 12.6 15.7 320 400 Shaft 15 mm x 12 m—for Use with Pistol Handles 7.9 15.7 200 400 8 GS2AE2/AE21 Shafts OPERATOR MECHANISMS AND DISCONNECT SWITCHES Shaft 5 mm x 5 mm—for Use with Pistol Handles, Type G GS2AH160 © 2009 Schneider Electric All Rights Reserved CP1 Discount Schedule 8-7 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IEC Style Disconnect Switches GS1/GS2 Fusible and LK3/LK4 Non-Fusible, UL 98 Listed Refer to Catalog 9421CT0301 www.schneider-electric.us Accessories Table 8.34: Auxiliary Contacts Type Description Catalog No. $ Price For Compact LK3 / GS1 Contact holder (for 5 to 8 auxiliary contacts). Standard products allow GS1AD10 46.70 up to 4 auxiliary contacts without any extra contact holders. 10 A 1 N.O. Contact Block GS2AM110 14.70 600 Vac 1 N.C. Contact Block GS2AM101 14.70 For LK4 60–200 A, GS2 30–800 A U = Upper or Top mounted Contact holder required (for 1 to 8 upper auxiliary contacts) GS2AD11 46.70 10 A 1 N.O. Contact Block GS2AM110 14.70 600 Vac 1 N.C. Contact Block GS2AM101 14.70 1 N.O. & N.C. Contact Block (max of two blocks – any mix) GS1AN11 78.00 S = Side mounted a 2 N.O. & N.C. Contact Block (max of two blocks – any mix) GS1AN22 140.00 1 N.O. & N.C. Contact Block w/ Test (max of two blocks – any mix) GS1ANT11 93.00 S = Side mounted a 2 N.O. & N.C. Contact Block w/ Test (max of two blocks – any mix) GS1ANT22 156.00 For LK3 400–1200 A U = Upper or Top mounted Contact holder (for 1 to 4 auxiliary contacts) LK3AD30 46.70 10 A 1 N.O. Contact Block GS2AM110 14.70 600 Vac 1 N.C. Contact Block GS2AM101 14.70 a GS1AN• • contact blocks cannot be mixed with GS1ANT• • contact blocks on the same switch. You must use all GS1AN11/GS1AN22 on a single switch OR all GS1ANT11/GS1ANT22 on a single switch. U = Upper or Top mounted GS2AM110 + GS2AM101 GS1AD10 + GS2AM110 Table 8.35: Terminal Lugs For use on # of Wires per Lug 1 1 1 1 1 1 1 Wire Size Wire Type Lugs per Kit Catalog No. $ Price Compact GS1/LK3 #14–#10 Cu — Standard — GS2 30 A CC #14–#10 Cu — Standard — GS2 30 A J #14–#10 Cu — Standard — GS2/LK4 60 A J #10–#3 Cu — Standard — LK4 100 A #14–#2/0 Cu — Standard — GS2 100 A #14–2/0 Cu/Al 6 GS1AW303 59.00 GS2/LK4 200 A #6–3/0 Cu/Al 6 GS1AW403 98.00 GS2 400–800 A 2 x 2–2 x 600 2 Cu/Al 6 GS1AW503 197.00 LK3 400–600 A a LK3 800–1200 A a 4 x 2–4 x 600 2 Cu/Al 12 GS1AW903 395.00 a GS1 600–800 A and LK3 800–1250 A can receive 1 lug for 3 cables per terminal or 2 lugs for 2 cables per terminal. Terminal Lugs Table 8.36: For use on GS2JU3 GS2MU3 GS2QU3 GS2MU3 GS2QU3 Power Distribution Lugs Wire Size AWG (mm2) #8 (10) – #6 (16) #14 (2.1) – #10 (6) #6 (16) – #4 (35) #8 (10) #14 (2.1) – #10 (6) #2 (35) – #2/0 (70) #6 (16) – #4 (25) #8 (10) #12 (3.3) – #10 (4) Table 8.37: Terminal Shrouds # of Wires Per Lug Wire Type Lugs per Kit Catalog Number $ Price 6 Cu 3 GS1AW306 126.00 12 Cu 3 GS1AW406 209.00 6 Cu 3 GS1AW506 233.00 Terminal Shrouds 8 For use on Line or Load Side a Compact GS1/LK3 All GS2/LK4 30 A All GS2/LK4 60 A LK4 100 A GS2 100 A b GS2/LK4 200 A b GS2 400 A LK3 400–600 A GS2 600–800 A LK3 800–1200 A a All GS1 and LK3 switches supplied with line side shrouding. b Three piece kit for either line or load side. Table 8.38: OPERATOR MECHANISMS AND DISCONNECT SWITCHES Shorting Links per Kit 3 3 3 3 3 Table 8.39: 8-8 Catalog No. GS1AU203 GS1AU303 GS1AU403 GS1AU503 GS1AU803 $ Price 29.60 41.90 62.10 93.00 156.00 Shaft Padlocking Kit For use on Compact GS1/LK3 LK4 60–200 A GS2 30–400 A LK3 400–1200 A GS2 600–800 A CP1 $ Price — — — — 101.00 132.00 140.00 86.00 140.00 101.00 Shorting Links For use on GS2 60 A GS2 100 A GS2 200 A GS2 400 A GS2 600–800 A Shorting Links Catalog No. Standard Standard Standard Standard GS1AP33 GS1AP43 GS1APU53 LK3AP63 GS2AP73 LK3AP83 Discount Schedule Catalog No. Standard Standard Standard GS1AXU3 Standard $ Price — — — 62.00 — © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions IEC Style Disconnect Switches, UL 98 Listed Refer to Catalog 9421CT0311 www.schneider-electric.us GS1DDU3, 30 A Compact Class CC Fuses 1.83 " 3 34 " Door Drilling 1 8 96.5 " 2 ø 4.5 19 32 37.3 15 2 12 " " 11 4 " 65 -OFF 63 2.48" 2" ø 31 50 1 15 32 " 1" 25.6 45 1 25 32 " 79.5 3 18 " 116 1.72 1.10 1.57 43.9 28 40 ON FIX 4 169 " 90 -ON TEST 18.3 23 32 " 2.75 FIX ø 90° 70 3" 16 Ø 0.27 (4) 7 Ø 1.22 31 65° OFF 3 14 " 83.8 M5 GS2AH/AHT110, 120, 410 or 420 GS1DU3, 30 A Compact Class J Fuses 4.13 1.83 46.5 105.5 .059 15 2.48 63 -OFF 90 3.38 84 116 2.0 50 1.25 ø 31 1.0 28 1.47 37.3 4.56 Door Drilling 0.13 2 ø 4.5 2.5 65 GS1AH101 or 102 -ON 28 40 43.9 FIX 1.10 1.57 1.72 ON 15.8 0.63 TEST 90° 3.88 99 FIX ø 0.19 2.75 65° Ø 0.27 (4) 7 Ø 1.22 31 OFF 70 GS2AH/AHT110, 120, 410 or 420 GS2EEU3, 30 A Class CC Fuses 1.72 5.69 43.9 144 1.13 Fix 29 1.10 1.57 5.88 ON 149 2.63 67 TEST 2.75 70 90° 2.44 62 28 40 Fix 5.25 133 OPERATOR MECHANISMS AND DISCONNECT SWITCHES Door Drilling 3.88 99 65° OFF Ø 0.27 (4) 7 Ø 1.22 31 Mounting Hole Dimension 0.19 in. (4.8 mm) 8 GS2 AH / AHT 110, 120, 410 or 420 © 2009 Schneider Electric All Rights Reserved 8-9 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions GS1 Fusible and LK3 Non-Fusible Disconnect Switches Refer to Catalog 9421CT0301 www.schneider-electric.us GS2EU3/GS2GU3, GS2 30 A/60 A Class J Fuse Clips 1.72 43.9 5.63 143 1.50 3.50 38 Door Drilling 89 5.88 ON TEST 2.75 67 28 40 149 2.63 1.10 1.57 Fix 5.25 133 Ø 0.27 (4) 7 70 90° Ø 1.22 65° 31 OFF 2.75 70 Mounting Hole Dimension: 0.19 in. (4.8 mm) 6.75 171 GS2JU3, GS2 100 A Class J Fuses 1.72 43.9 5.63 2.06 143 Terminal Lugs 2/0 Max. Door Drilling 3.44 52 .25 87 Fix 6.56 167 7.19 183 3.31 40 .63 TEST 16 .88 Ø 0.27 (4) 22 70 .75 7 90° 3.31 8.25 28 ON 2.75 84 Ø6.9 1.10 1.57 84 19 Ø 1.22 31 65° OFF Mounting Hole Dimension: 0.19 in. (4.8 mm) 210 GS2MU3, GS2 200 A Class J Fuses 1.75 44.6 6.00 152 Fix 2.44 62 3.44 Terminal Lugs 3/0 Max. Door Drilling 87 8.13 ST 3.75 95 11 Ø11.6 28 40 TE ON 207 .44 1.10 1.57 Fix 7.50 191 Ø 0.27 (4) 7 4.95 125.1 90° Ø 1.22 31 65 1.00 25 1.13 1.50 29 38 3.69 94 OFF 9.44 240 Mounting Hole Dimension: 0.19 in. (4.8 mm) GS2QU3, GS2 400 A Class J Fuses 5.56 2.81 Fix 2.81 72 1.75 72 141 44.6 3.44 Terminal Lugs 2 x 600 MCM Max. Door Drilling 87 .38 363 ST 4.44 Ø .25 6 11.94 303 28 40 TE ON 112 1.10 1.57 Fix 8.81 224 14.31 3.13 Ø 0.27 (4) 4.95 80 1.50 38 7 125.1 90° Ø 1.22 31 65 2.06 52 10 Ø 10.2 2.88 73 OFF Mounting Hole Dimension: 0.25 in. (6.3 mm) 8 GS2SU3/GS2TU3, GS2 600 A Class J AND 800 A Class L Fuses OPERATOR MECHANISMS AND DISCONNECT SWITCHES Ø 9.38 2.50 64 Fix 13.63 346 Fix 9.88 251 1.50 38 3.13 80 7.13 4.13 .25 106 4.75 4.75 120 120 64 7.50 .50 190 4.00 13 100 3.13 1.50 3.56 38 1.56 2.88 3.00 80 20.38 517 Ø 0.27 (4) 7 2.50 8.26 209.8 59 Drilling Terminal Lugs 2X600 MCM Max. 3X600 MCM Max. Ø 44 Ø .38 2.75 11 10 69 362 2.38 Ø 1.22 31 7 Locking 55° 9.88 250 6.00 14.25 152 492 28 40 181 19.38 1.10 Door 1.57 2.40 61.1 91 73 40 76 Mounting Hole Dimension: 0.38 in. (9.6 mm) 8-10 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions GS1 Fusible and LK3 Non-Fusible Disconnect Switches Refer to Catalog 9421CT0301 www.schneider-electric.us LK3DU3, Compact LK3 30 A 2.59 3.78 66 96 1.00 .59 1.94 15 37 19 1.00 25 25 .75 Door Drilling .13 2.00 2 Ø 4.5 1.83 51 46 4.56 116 1.78 Fix 3.13 45 80 1.25 3.84 0-OFF Ø 31 98 .56 14 90° -ON 2.48 .72 63 Fix Ø .19 M5 18 Mounting Hole Dimension: 0.19 in. (4.8 mm) LK3GU3/LK3JU3, LK3 60 A/100 A 1.72 43.9 3.88 99 Ø .19 5 3.50 Fix 1.50 38 Door Drilling 89 1.10 1.57 149 28 40 Fix 5.25 133 5.88 ON 2.63 TEST 2.75 67 Ø 0.27 (4) 7 70 90° Ø 1.22 31 65° OFF 2.75 70 6.69 Mounting Hole Dimension: 0.19 in. (4.8 mm) 170 LK3MU3, LK3 200 A Mounting Hole Dimension: 0.19 in. (4.8 mm) 1.75 44.6 2.44 Ø .19 5 3.44 87 62 Door Drilling Terminal Lugs 3/0 Max. .44 Fix 7.50 191 8.13 TE ON 3.75 95 28 40 206 ST Ø 0.27 (4) 7 4.95 125.1 1.50 38 1.00 25 1.13 29 Ø 1.22 31 90° 3.69 11 Ø11.6 1.10 1.57 65 94 9.50 241 OFF LK3QU3/LK3SU3, LK3 400 A/600 A Terminal Lugs 2 x 600 MCM Max. 6.56 166 3.13 1.56 .38 1.63 5.00 Fix 12.63 320 127 10 Ø 10.2 Door Drilling 41 80 40 1.10 1.57 28 40 Fix 6.88 175 2.31 3.13 80 59 Ø 1.22 31 8.26 20 2.88 .56 14 11.00 38 Ø 0.27 (4) 7 209.8 .81 1.50 73 Fix 10.06 255 279 2.40 Mounting Hole Dimension: 0.25 in. (6.3 mm) 61.1 Door Drilling 1.57 6.56 6.81 2.50 173 166 4.75 40 121 64 Ø 1.22 Ø 0.27 (4) 31 7 Terminal Lugs 2X600 MCM Max. 3X600 MCM Max. Ø 44 Ø .38 11 10 13.00 330 Fix 6.88 175 2.31 .81 59 20 8.26 .81 20 14.63 372 2.50 209.8 1.56 40 1.10 28 40 1.56 OPERATOR MECHANISMS AND DISCONNECT SWITCHES LK3TU3/LK3UU3/LK3WU3, LK3 800 A/1000 A/1250 A 64 Fix 13.69 347 3.13 80 1.50 3.56 38 1.56 2.88 3.00 91 40 2.40 61.1 73 76 8 Mounting Hole Dimension: 0.38 in. (9.6 mm) © 2009 Schneider Electric All Rights Reserved 8-11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NEMA Style Disconnect Switches NEMA Style Door Mounted Disconnect Switches Refer to Catalog 9420CT9701 www.schneider-electric.us File D10 The D10 disconnect switch features high I2T rating, longer contact life, visible contact indication, fuse-mounting flexibility, dead-front construction, and auxiliary interlocks. A complete installation includes a D10 disconnect switch, D11 handle operator, and D12 fuse clip kit. The D10 accepts Class H, K, J, or R fuses or can be used for non-fusible applications. The D10 disconnect switch is operated by a cast metal handle operator that is lockable in the “OFF” position and defeatable in the “ON” position. Table 8.40: Disconnect Switches (without fuse clips or shorting straps) Table 8.44: Max. Horsepower Ratinga Rating (A) 120 V 200– 240 V 480 V 30 60 100 200 5 10 15 25 10 20 30 50 20 40 60 100 600 V Catalog Number $ Price 25 50 75 100 D10S1 D10S2 D10S3 D10S4 270.00 292.00 452.00 860.00 a B F Complete Kit with 30, 60, Handle, Shaft, and 100, 200 Actuator A E Centerline of Switch Operating Shaft I J D C Catalog Number $ Price D10S1H D10S2H D10S3H D10S4H 320.00 352.00 544.00 1154.00 Rotary Handle Operator Kits and Shafts Rating (A) 30, 60, 100, 200 Shaft only Table 8.42: Enclosure Interior Depth—Inches 5–6 6–10 10–16 6 12 Catalog Number D11SF4 D11SF10 D11SF16 D11SH10 D11SH16 $ Price 106.00 118.00 130.00 26.20 32.80 Auxiliary Electrical Interlock (for mounting on 30 A—200 A disconnect switch a) Block Description (with switch contacts open) 1 N.O. 1 N.C. 1 N.O. and 1 N.C. 2 N.O. 2 N.O. and 2 N.C. a One block per switch. Table 8.43: Catalog Number $ Price D11N0 D11NC D11N0C D11N00 D11N0C2 79.00 79.00 116.00 116.00 130.00 Interrupting and Withstandability Ratings Interrupting Rating Withstandability I2T Amperes Symmetrical (Amperes2 seconds) 600 Vac, 3Ø 30 1,200 0.38 x 106 60 1,800 1.28 x 106 100 2.000 2.62 x 106 200 3,600 5.25 x 106 Note: These switches are for motor circuit applications. Rating (A) 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES Table 8.46: Cu Cu Al–Cu Al–Cu Fuse Clip Kits Switch Dimensions (in inches) Length Width Mounting Hole Dimensions Depth Rating (A) A B C D E F G H I J Ka lb 30 7-5/16 4-15/32 5-7/8 3-15/32 6 3-15/32 1-7/8 13/32 5-7/16 3-1/4 4-3/32 4-11/32 60 7-5/16 4-15/32 5-7/8 3-15/32 6 3-15/32 1-7/8 13/32 5-7/16 3-1/4 4-11/32 4-11/32 100 9-27/32 5-11/32 8-3/16 4-5/8 5-13/16 3-13/16 2-11/16 51/64 7-5/16 4-3/16 5-23/32 4-27/32 12-3/16 7-7/32 8-3/16 4-5/8 5-13/16 3-13/16 2-11/16 51/64 7-5/16 4-3/16 5-23/32 4-27/32 200 a b 8-12 Wire Type #14–#8 #14–#4 #14–#1/0 #6–250 kcmil Fuse Clip Rating a Catalog $ Price Number Amperes AC Volts Type No Fuse D12C01 8.30 16.30 0–30 250 H, K D12C21 0–30 250 R D12CR21 65.00 24.50 0–30 600 H, K D12C61 0–30 600 R D12CR61 65.00 30 A 0–30 600 J D12CJ1 49.30 31–60 250 H, K D12C22 24.50 31–60 600 H, K D12C62 49.30 31–60 600 R D12CR62 82.50 31–60 600 J D12CJ2 57.50 61–100 250 H, K D12C23 65.00 No Fuse D12D02 24.50 0–30 250 R D12DR21 65.00 0–30 600 H, K D12D61 24.50 0–30 600 R D12DR61 65.00 31–60 250 H, K D12D22 23.80 31–60 250 R D12DR22 82.50 60 A 31–60 600 H, K D12D62 41.00 31–60 600 R D12DR62 82.50 31–60 600 J D12DJ2 57.50 61–100 250 H, K D12D23 65.00 61–100 600 H, K D12D63 115.00 61–100 600 J D12DJ3 106.30 61–100 600 R D12DR63 113.80 No Fuse D12E03 49.30 31–60 250 H, K D12E22 41.00 31–60 600 H, K D12E62 41.00 61–100 250 H, K D12E23 32.50 61–100 250 R D12ER23 115.00 100 A 61–100 600 H, K D12F63 90.00 61–100 600 R D12FR63 115.00 61–100 600 J D12EJ3 115.00 101–200 250 H, K D12F24 106.30 101–200 600 H, K D12F64 122.50 101–200 600 J D12FJ4 140.00 No Fuse D12F04 82.50 61–100 600 H, K D12F63 90.00 101–200 250 H, K D12F24 106.30 200 A 101–200 250 R D12FR24 140.00 101–200 600 H, K D12F64 122.50 101–200 600 R D12FR64 135.00 101–200 600 J D12FJ4 140.00 a Continuous current should not exceed switch rating (size). Fuse clip kits should be sized to accommodate inrush. Kits include: Handle, shaft, and actuator NEMA Type 1, 3, 3R, 4, and 12 Description G H Wire Range a D10 Switch Size Starter Max. Horsepower Rating a NEMA Rating 200– 480 V 600 V Type (A) 120 V 240 V Size 0–1 30 5 10 20 25 2 60 10 20 40 50 3 100 15 30 60 75 4 200 25 50 100 100 a Non-fused ratings Table 8.41: 30 60 1 100 200 One conductor per lug. Table 8.45: 600 V—With Service Entrance Rating Line Shield Number Per Pole Rating (A) 600 V—Without Service Entrance Rating Starter NEMA Type Size 0–1 2 3 4 Lug Data Maximum depth with largest fuse. Depth including insulating barrier on service entrance switches. CP1 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NEMA Style Disconnect Switches Door-Mounted Operating Mechanisms for Square D Circuit Breakers Class 9421 / Refer to Catalog 9420CT9701 www.schneider-electric.us Type L Circuit Breaker Mechanisms Type L door-mounted, variable depth operating mechanisms feature heavy duty, all metal construction with trip indication. All can be padlocked in the “OFF” position when the enclosure door is open. Further, the handle assemblies can be locked “OFF” with up to three padlocks, which also locks when the door is closed. (The 3” handle accepts one padlock.) Complete kits are rated for NEMA Type 1, 3R, and 12 enclosures. They include a handle assembly, operating mechanism, and shaft assembly. Table 8.47: Complete Kits Complete Kit Does Not Include Circuit Breaker Includes: Operating Mechanism Standard 6 in. Handle Standard Shaft Kit Use With Circuit Breaker or Interrupter Type Frame Size (A) Type Mounting $ Price Depth a Min. – Max. Type Mounting $ Price Depth a Min. – Max. Type Mounting $ Price Depth a Min. – Max. 3 75, 100 LG1 140.00 5-1/2–10-1/4 LG4 158.00 5-1/2–20-7/8 LG3 198.00 5-1/2–20-7/8 FAL, FCL, FHL 2–3 100 LN1 140.00 5-1/2–10-7/16 LN4 158.00 5-1/2–21 LN3 198.00 KAL, KCL, KHL 2–3 250 LP1 171.00 6-1/4–11-3/16 LP4 189.00 6-1/4–21-3/4 LP3 230.00 6-1/4–21-3/4 NSF, PowerPact® H and J 2–3 250 LJ1 171.00 5-1/2–10-3/4 LJ4 189.00 5-1/2–21-3/8 — LALc, LHLc, Q4L 2–3 400 LR1 242.00 6-5/16–10-7/8 LR4 255.00 6-5/16–21-1/2 MEL, MXL 2–3 800 LT1b 242.00 7-3/16–11-5/8 LT4b 255.00 7-3/16–22-1/4 MAL, MHL 2–3 1200 LT1b 242.00 7-3/16–11-5/8 LT4b 255.00 7-3/16–22-1/4 NAL, NCL, NEL, NXL 2–3 1200 LX1b 242.00 8-1/4–12-3/4 LX4b 255.00 8-1/4–23-3/8 PowerPact M and P e 3 1200 LW1d 242.00 7-3/16–11-5/8 LW4d 255.00 7-3/16–22-1/4 5-1/2–21 — — 3 in. handles are not recommended for use with these circuit breakers. Component Parts 3 in. Handle Standard Handle Assemblies Assemblies Type 1, 3R, 12 Type 1, 3R, 12 Use With Circuit Breaker or Interrupter Type GJL No. of Poles Frame Size (A) Type $ Price Type Operating Mechanism Includes Lockout $ Price Type Standard Shaft (Support Bracket Not Required) Mounting $ Price Depth a Min. – Max. Long Shaft (Support Bracket Included) Mounting Type $ Price Depth a Min. – Max. Type $ Price 3 75, 100 LH3 90.00 LH6 50.00 LG7 68.00 5-1/2–10-7/16 LS8 21.50 5-1/2–21 LS13 35.60 FAL, FCL, FHL 2–3 100 LH3 90.00 LH6 50.00 LF1 71.00 5-1/2–10-7/16 LS8 21.50 5-1/2–21 LS12 35.60 KAL, KCL, KHL 2–3 250 LH3 90.00 LH6 50.00 LK1 105.00 6-1/4–11-3/16 LS8 21.50 6-1/4–21-3/4 LS12 35.60 NSF, PowerPact H and J 2–3 250 LH3 90.00 LH6 50.00 LJ7 105.00 5-1/2–10-1/4 LS8 21.50 5-1/2–21-3/8 LS13 35.60 LALc, LHLc, Q4L 2–3 400 LH6 50.00 LL1 170.00 6-5/16–10-7/8 LS8 21.50 6-5/16–21-1/2 LS10 35.60 MEL, MXL 2–3 800 LH8 50.00 LM1 170.00 7-3/16–11-5/8 LS8 21.50 7-3/16–22-1/4 LS10 35.60 MAL, MHL 2–3 1200 LH8 50.00 LM1 170.00 7-3/16–11-5/8 LS8 21.50 7-3/16–22-1/4 LS10 35.60 NAL, NCL, NEL, NXL 2–3 1200 LH8 50.00 LX7 170.00 8-1/4–12-3/4 LS8 21.50 8-1/4–23-3/8 LS10 35.60 PowerPact M and Pe 3 1200 LHP8 50.00 LW7 170.00 7-3/16–11-5/8 LS8 21.50 7-3/16–22-1/4 a Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door in inches. b Types LT1, LT4, LX1, and LX4 include an 8 in. handle rather than a 6 in. handle. c Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. d Type LW1 and LW4 include an 8 in. handle (9421LHP8) rather than a 6 in. handle. e These circuit breakers must use the 9421LHP** or LCP** handles only. LS10 35.60 Table 8.49: 3 in. handles are not recommended for use with these circuit breakers. NEMA Type 4 and 4X Handle Assemblies a Use With Standard Handle Assemblies NEMA Type 1, 3R, 4, 12 (Painted) Special 3 in. Version NEMA Type 1, 3R, 4, 4X, 12 (Chrome Plated) NEMA Type 1, 3R, 4, 12 (Painted) NEMA Type 1, 3R, 4, 4X, 12 (Chrome Plated) No. of Poles Frame Size (A) Type $ Price Type $ Price Type $ Price Type $ Price 3 75 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00 FAL, FCL, FHL 2–3 100 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00 KAL, KCL, KHL 2–3 250 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00 NSF, PowerPact H and J 2–3 250 LH46 90.00 LC46 149.00 LH43 165.00 LC43 233.00 LAL, LHL, Q4L 2–3 400 LH46 90.00 LC46 149.00 Circuit Breaker or Interrupter Type GJL MEL, MXL 2–3 800 LH48 90.00 LC48 149.00 MAL, MHL 2–3 1000 LH48 90.00 LC48 NAL, NCL, NEL, NXL 2–3 1200 LH48 90.00 LC48 in. handles are not recommended for use 149.00 3 with these circuit breakers. 149.00 PowerPact M and P 3 1200 LHP48 90.00 LCP48 a Due to gasketing, NEMA Type 3 & 4 handle assemblies are NOT trip indicating. Table 8.50: IEC Style Operating Mechanisms GJL Color Red/Yellow Type NW3 Black NW3B Extension Shafts Operating Mechanism Includes Lockout Type 1, 4, 4X, 12 Circuit Breaker or Interrupter Type a 149.00 $ Price 90.00 90.00 Type LG8 Mounting Depth $ Price $71.00 Min. 6-1/8 Max. 10-3/4 Type $ Price NS16 28.70 6-1/8 17-7/8 NS336a 35.60 Contains support bracket. Table 8.51: Electrical Interlock Kits—Class 9999 a Description Class Type $ Price Single Pole Double Throw 9999 R47 131.00 Double Pole Double Throw 9999 R48 221.00 a Optional accessory for use with 9421L operating mechanisms. Note: Not used with GJL, NAL, NCL, NEL, NXL, NSF, NSJ, PowerPact® C, D, H, and J circuit breakers; use field-installed circuit breaker interlocks instead. © 2009 Schneider Electric All Rights Reserved CP1 Discount Schedule OPERATOR MECHANISMS AND DISCONNECT SWITCHES Table 8.48: Standard Handle Assembly Includes: Operating Mechanism Short 3 in. Handle Long Shaft Kit No. of Poles GJL 3 in. Handle Assembly Includes: Operating Mechanism Standard 6 in. Handle Long Shaft Kit 8 Operating Mechanism 8-13 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions Door Mounted Operating Mechanisms Class 9421 / Refer to Catalog 9420CT9701 www.schneider-electric.us 3.50 Min. 1.38 Refer to NEC Article 430-10 for minimum dimension from top mounting hole to wall or barrier X to insure adequate wire bending space. 45 1.18 30 .50 13 35 L 4.72 1.77 45 120 CLHandle Mechanism 3.94 100 Screw Driver Interlock Pin Location .45 .28 Maximum 12 7 Door Thickness CLHandle Mechanism (2) #8-32 Tap 2.38 60 H Mounting Depth a Panel drilling for GJL circuit breaker and operating mechanism L = Overall shaft length H = Distance from inside of enclosure door to circuit breaker mounting surface Table 8.52: Shaft Cutting Dimensions Class a Type Shaft Length Formula H = Standard Shaft H = Long Shaft Min. Max. L = H–2.50 5.50 10.25 9421 LG7, LG1, LG4, LG3 64 140 260 L = H–2.88 5.50 10.44 9421 LF1, LN1, LN3, LN4 73 140 265 L = H–3.63 6.25 11.19 9421 LK1, LP1, LP3, LP4 92 159 284 L= H–3.00 5.5 10.75 9421 LJ1, LJ4, LJ7 76 138 273 L= H–3.13 6.31 10.88 9421 LL1, LR1, LR4 79 160 276 L= H–4.00 7.18 11.63 9421 LM1, LT1, LT4 102 182 295 L= H–5.17 8.25 12.75 9421 LX7, LX1, LX4 131 210 324 L= H–4.89 7.19 11.63 9421 LW1, LW4, LW7 124 183 295 Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door. 3.25 Minimum 83 (Both Sides) 7.00 4.50 2.25 114 Hinge Point of Door 1.50 38 57 .75 19 1.63 R 41 1.56 40 178 Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10. CL Handle Mechanism Min. 5.50 140 5.50 140 6.25 159 5.5 138 6.31 160 7.18 182 8.25 210 7.63 183 Max. 20.85 530 21.00 533 21.75 552 21.63 543 21.50 546 22.25 565 23.38 594 22.25 565 3.25 Minimum 83 13.50 (Both Sides) 4.50 2.25 114 Hinge Point of Door 1.50 38 57 .75 19 1.81 46 343 Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10. 5.13 7.13 6.00 152 181 CL Handle & Ckt. Bkr. T oggle OPERATOR MECHANISMS AND DISCONNECT SWITCHES (4) #8-32 Tap CL Handle & Ckt. Bkr. T oggle 8 130 1.63 R 41 6.00 152 (4) #10-24 Tap C30080-120 Panel drilling for FAL, FCL, FHL circuit breaker and operating mechanism 8-14 Panel drilling for KAL, KCL, KHL circuit breaker and operating mechanism © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions Door Mounted Operating Mechanisms Class 9421 / Refer to Catalog 9420CT9701 www.schneider-electric.us 6.00 Minimum 152 (Both Sides) Hinge 6.00 Point 3.00 152 of Door 76 2.00 2.00 51 .88 487 Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used with standard lugs. Refer to NEC Article 430-10. 51 1.00 22 25 CL Circuit Breaker 4.57 8.00 Minimum 203 (Both Sides) Hinge 4.50 Point 114 of Door 19.19 229 51 76 1.50 38 42 (4) 5/16-18 Tap 40 4.937 (4) 1/4-20 Tap CL Circuit Breaker 125 3.09 79 (4) 1/4-20 Tap 1.03 .56 41 14 9.25 235 4.68 (4) #12-24 Tap 119 CL Handle CL Handle X Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10. 2.00 1.66 1.59 116 1.63R 9.00 3.00 26 A CL Handle 2.68 3.50 89 68 .38 .44 11 .38 CL Handle B 10 8.00 10 203 .44 6.00 11 152 1.63R .88 41 7.19 22 183 5.09 10.19 129 259 Panel Drilling for PowerPact® H and J Circuit Breakers and Operating Mechanism Panel Drilling for LAL, LHL, and Q4L Circuit Breakers and Operating Mechanism Panel Drilling for MAL, MEL, MHL, and MXL Circuit Breakers and Operating Mechanism Dimensions = in. (mm) Circuit Breaker Type A B MAL, MHL 10.69 (272) 14.00 (356) MEL, MXL 11.47 (291) 14.75 (375) C Minimum to wall or barrier to insure adequate wire bending MIN.: 8 in. (203 mm) (both sides) X space to lug surface when M 7.83 199 3.92 100 1.70 43 maximum wire size is used. Refer to NEC Article 430-10. 1200 A: 16.26 413 64 N (4) 1/4-20 tap P (4) #10-32 tap 12.13 Q 241 CL Handle Mechanism 8.75 222 7.87 200 9.50 800 A: 12.86 327 308 1.63R 41 8.00 R 1200 A: 4.10 104 2.51 64 203 CL Circuit Breaker 800 A: 2.49 63 8.50 216 R Panel Drilling for NAL, NCL, NEL, and NXL Circuit Breaker and Operating Mechanism 5.24 133 10.48 266 8.27 210 3.02 77 Dim. = in. mm OPERATOR MECHANISMS AND DISCONNECT SWITCHES L 9.00 Minimum (Both Sides) Handle Mechanism 229 15.00 381 Hinge 3.16 7.50 Point 80 191 of Door 5.00 1.66 127 42 (4) 1/4-20 Tap 2.50 8 Panel Drilling for PowerPact® M and P Circuit Breaker and Operating Mechanism © 2009 Schneider Electric All Rights Reserved 8-15 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Disconnect Switches Flange Mounted, Variable Depth, and Cable Operated Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us The Class 9422 Type TCF, TCN, TDF, TDN, TEF, TEN disconnect switches were designed for control panel installations. These switches include common switch profile 30–100 A, interchangeable fuse clips 30–60 A, and the ability to add fuse clip kits and cable mechanisms. They are compatible with 9422A and 9423, and are UL recognized and CSA certified. Table 8.53: Class 9422 Flange Mounted, Variable Depth Disconnect Switches Variable Depth Disconnect Mtg. Switch Range Size Min.–Max. (in.) Maximum Horsepower Ratings AC Systems Volts (Motor Volts) 208 240 480 600 (200) (230) (460) (575) Fuse Clip Rating (Amperes) NonInterchangeable Type For Class H, J, K or R Fuses Only Fuse Type DC Using 2 Poles 250 V Max. 250 V None 30 A 6-5/8–18 7.5 7.5 15 20 5 60 A 6-5/8–18 15 15 30 50 10 100 A 6-5/8–18 25 30 60 75 20 H, K, J, R None H, K, J, R None H, K, J, R — 30 60 — 60 — — 100 200–400 A Table 8.54: Switch and Operating Mechanism Only— Does Not Include Handle Mechanism 600 V Type Switch for Use With Cable Operators ONLY— Does Not Include Handle Mechanism or Cable Operator $ Price — TCN30 329.00 — TCF30 372.00 30 TCF33 399.00 — TDN60 386.00 30 TDF60 458.00 60 TDF63 485.00 — TEN10 570.00 100 TEF10 783.00 See 9422 TF and TG on page 8-17 Switch and Operating Mechanism and Handle Mechanism—Overpacked Includes Type A1 Handle Mechanism Includes Type A2 Handle Mechanism Type $ Price Type $ Price Type $ Price TCN30C TCF30C TCF33C TDN60C TDF60C TDF63C TEN10C TEF10C 315.00 359.00 386.00 372.00 444.00 471.00 557.00 770.00 ATCN301 ATCF301 ATCF331 ATDN601 ATDF601 ATDF631 ATEN101 ATEF101 471.00 513.00 543.00 527.00 599.00 629.00 714.00 926.00 ATCN302 ATCF302 ATCF332 ATDN602 ATDF602 ATDF632 ATEN102 ATEF102 585.00 629.00 660.00 642.00 714.00 741.00 827.00 1040.00 Internal Barrier Kits Provide an additional barrier that helps prevent accidental contact with live parts. Field installed transparent barriers do not restrict visual inspection of the switch. Barriers provide IEC529 IP2X “finger safe” protection when the door of the enclosed disconnect switch is open. A convenient door allows use of test probes without accessing fuses and replacement of fuses without removing barrier. Barrier must be used with the skirt kit to enclose a panel mounted type 9422 disconnect. Catalog No. ab Safety Switch Application (F series only) Description SS06 Interior barrier for 60 A safety switch, 30 or 60 A 9422 switch 600 Vac–60 A SS10 Interior barrier for 100 A safety switch or 100 A 9422 switch 600 Vac–100 A SS0306SK Skirt kit to enclose 30 or 60 A 9422 switch (requires SS06) — SS10SK Skirt kit to enclose 100 A 9422 switch (requires SS10) 30528-358-50S Interior barrier for 200 A 9422 disconnect switch 30528-369-50S Interior barrier for 400 A 9422 disconnect switch a No Class Number is required. b For price, use Discount Schedule DE1, not CP1 Table 8.55: Disconnect Switch Size 30 A 60 A Table 8.56: Disconnect Switch Size Switch Type Fuse Type TCF30 TCN30 H, K, J, R TCF33 TDN60 H, K, J, R Fuse Clip Rating (Amperes) 250 V 30 600 V — 1.41 Line and Load Fuse Clip Kit (includes load base and fuse pullers) Type TC30 220.00 260.00 300.00 340.00 272.00 390.00 30 TC33 71.00 60 — 30 60 TC33 TD63 71.00 99.00 Fuse Type 100 A = 5.75 1.00 Rejection Feature — Class R Kit b 250 V 30 60 60 — 100 Cat No. a RFK03 RFK06 RFK06 RFK06H RFK10 8 Disconnect Switch Size 1.00 4.50 8.80" Fuse Clip Rating (A) 600 V — 30 30 60 100 A B 0.30 $ Price 32.69 34.00 34.00 34.00 64.00 1.50* 100A = 5.10" Class 9999 Electrical Interlocks Switch Type Electrical Interlock Contacts SPDTa Type TC10 OPERATOR MECHANISMS AND DISCONNECT SWITCHES Disconnect Switch Size a D 4.00 5.50 6.20 *0.30 for 100 A Class J fuses TCF, TCN TDF, TDN 30 A DPDTb TC20 TEF, TEN 60 A BTCF, BTCN SPDTa TC11 100 A BTDF, BTDN DPDTb TC21 BTEF, BTEN a 1 N.C. or 1 N.O. depending on wiring. b 2 N.C., 2 N.O. or 1 N.O., 1 N.C. depending on wiring. Table 8.59: 4.00" 30 A = 3.50 60 A Class R Fuse Clip Kits Switch Type 1.41 $ Price 42.80 60 Table 8.57: 8-16 $ Price b Class 9422 Replacement/Retrofit Fuse Clip Kits TCF30 R TCF33 R TDF60 R 60 A TDF63 R 100 A TEF10 R a No Class Number required. b For price, use Discount Schedule DE1, not CP1. 30 A — — — 9422 Type T Disconnect Application 600 Vac–30 A 600 Vac–60 A 600 Vac–100 A 600 Vac–30 A 600 Vac–60 A 600 Vac–100 A 600 Vac–200 A 600 Vac–400 A $ Price 120.00 239.00 120.00 D = Distance from handle mechanism mounting surface to disconnect switch surface. D min. = 6 5/8" D max. = 18" Table 8.58: Switch Type 30 A, 60 A 239.00 100 A Dimensions Maximum Voltage 30 A, 250 V 30 A, 600 V 30 A, 600 V 60 A, 250 V 60 A, 600 V 60 A, 600 V 100 A, 250 V 100 A, 600 V 100 A, 600 V Fuse Type Class H, K, R H, K, R J H, K, R H, K, R J H, K, R H, K, R J Dimension A Dimension B 1.625 4.25 1.625 2.25 4.75 1.625 — — 3.25 5.25 3.25 Class 9422 Disconnect Switch Cable Operators (must purchase switch separately) Cable Mechanisms with A1 Handle for Types 1, 3, 3R, 4 and 12 Cable Mechanismsa Switch Type Cable Length Type 36 in. CFT30 30 A, TCF, TCN 48 in. CFT40 60 A, TDF, TDN 60 in. CFT50 100 A TEF, TEN 120 in. CFT10 Purchase handle mechanism separately (9422, A1, A2, A3 or A4). CP1 Discount Schedule $ Price 273.00 291.00 291.00 333.00 Type CFT31 — CFT51 CFT11 $ Price 417.00 — 432.00 476.00 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Disconnect Switches Flange Mounted, Variable Depth Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us Ordering Information The 9422 Type T disconnect switches are designed for variable depth, flange mounting applications. These switches are fully compatible with 9422 handle operators and 9423 door closing mechanisms. They feature: 200 and 400 A; fusible (Classes H, K, J, or R fuses) and nonfusible; right or left flange mounting (except 400 A, which mounts only right hand flange and requires a special enclosure), UL recognized, and CSA certified. Table 8.60: Disconnect Switches Maximum Horsepower Ratingsa Disconnect Switch Size Variable Depth Mounting Range Min.–Max. (in.) 208 (200) 240 (230) 480 (460) 600 (575) DC Using 2 Poles 250 V Max. 40 60 125 150 40 AC Systems Volts (Motor Volts) Fuse Clip Rating (A) Non-Interchangeable Type For Class H, J, K, or R Fuses Only 250 V 600 V Non-Fusible 200 A 9.12–19.25b Switch and Operating Mechanism and Handle Mechanism—Overpacked Switch and Operating Mechanism Only— Does Not Include Handle Mechanism Includes Type A1 Handle Mechanism Includes Type A2 Handle Mechanism Type $ Price Type $ Price Type $ Price TF1 1247.00 ATF11 1389.00 ATF21 1503.00 200 200 TF2 1389.00 ATF12 1530.00 ATF22 1646.00 — 400 TF3c 2052.00 ATF13c 2195.00 ATF23c 2307.00 400 A 11.38 Non-Fusible TG1fg 2672.00 Fixed Depthd (A5 or A6 Handle) 75 125 250 350 50 For handle selection, see Table 8.62. 400 A 15.87–19e 400 400 TG2fg 3027.00 Adj. Depthd (A7 or A8 Handle) a Refers to rating of switch only. b 9422 R2, shown on page 8-23, will extend maximum mounting depth 7 inches. c Accommodates Class J fuses only. d Switches are either fixed-depth or adjustable; the handle will determine installation. e In increments of 0.63 inches. f Commercially available enclosures may not accept type TG operating mechanisms. Contact enclosure manufacturer for availability of enclosures for use with these switches. g Right hand flange mounting only. Table 8.61: Class R Fuses Fusible disconnect switches on this page and page 8-16 will accept Class R fuses as standard. A field installable rejection kit is available which, when installed, rejects all but Class R fuses. With the rejection kit and Class R fuses installed, the switch is UL component recognized for use on systems with up to 200,000 RMS symmetrical amperes fault current available. Switch Rating (A) 200 400 ON 5.69 OFF 144 RESET TF TG 6 in. a 1.06 6 in. ae 4 in. a 12 in. (fixed depth) c 12 in. (adjustable depth)c 10 in. d a b c d e Type A1 200 A 400 A 200 A 400 A Type $ Price 9999 9999 SR4 SR5 47.60 107.00 NEMA Type Enclosure 1, 3, 3R, 4 (sheet steel), 12 4, 4X (stainless steel)b 1, 3, 3R, 4 (sheet steel), 12 4, 4X (stainless steel)b 1, 3, 3R, 4 (sheet steel), 12 4, 4X (stainless steel)b 1, 3, 3R, 4 (sheet steel), 12 4 (stainless steel) 1, 3, 3R, 4 (sheet steel), 12 4 (stainless steel) 1, 3, 3R, 4 (sheet steel), 12 4 (stainless steel) Type A1 A2 AP1 AP2 A3 A4 A5 A6 A7 A8 A9 A10 $ Price 143.00 257.00 188.00 338.00 143.00 257.00 251.00 320.00 300.00 372.00 158.00 270.00 Enclosure Flange 89 “On” 6.13 (9422 A1 and A2) .88 22 156 4.50 (9422 A3 and A4) 114 10.13 (9422 A9 and A10) 257 Stiffener Bracket CL of Operating Mechanism Door Interlock Hook Door Interlock Defeater Screw Door 2.16 55 9422 A1, A2, A3, A4, A9, and A10 Handles Use with 30–200 A switches and all circuit breaker mechanisms. All external metal parts are either stainless steel or a chrome-plated non-ferrous die casting. Use with 400 A Type TG1 and TG2 disconnect switches only. Use with Type D2 remote or dual adapter kit listed on page 8-24. Use with 9422 RM1 and 9422 CMP only. Optional accessory for use with disconnect switches listed on this page. Table 8.63: Electrical Interlocks For Use On Switch Type TF, ATF TG © 2009 Schneider Electric All Rights Reserved 600 Vac Class Table 8.62: Handle Mechanisms Handle mechanism kits are used with all disconnect switch and circuit breaker installations. The kits contain all parts necessary for mounting the handle to the flange of the enclosure. The Types A1–A4, A9–A10 are suitable for right or left hand flange mounting. Two mounting methods are offered. The Types A5–A8 handles are designed for right hand mounting only. Type of Handle 27 250 Vac 30 A, 60 A 100 A 200 A 400 A 3.50 Maximum Fuse Clip Rating Type Wire Size Minimum–Maximum #14–#2 Cu, #10–#2 Al #10–#0 Cu, #6–#0 Al #6–300 kcmil Cu or Al #4–500 kcmil Cu Class Single Pole Interlock Type 9999 9999 R8 R35 $ Price Class 83.00 275.00 9999 9999 CP1 Two Pole Interlock Type $ Price R9 R36 243.00 521.00 Discount Schedule Rod used only on the variable-depth mechanism. The type AP1 and AP2 handles are used exclusively on the PowerPact® M and P Operating Mechanisms, 9422 RM1 and 9422 CMP. The dimensions are identical to 9422 A1. OPERATOR MECHANISMS AND DISCONNECT SWITCHES 29 Lug Data Disconnect Switch Size 8 1.13 Table 8.64: 8-17 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Disconnect Switches Flange Mounted, Variable Depth Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us Dimensions Table 8.65: Type TF1 Dimensions (in. / mm) for 200 A Type TF Disconnect Switches Switch Size (A) Fuse Clips 200 None TF2 200 TF2 200 TF2 200 TF3 200 Class J 200 A 600 V Class H, K, R 200 A 250 V Class H, K, R 200 A 600 V Class J 400 A 600 V a Da A B C 13.33 339 13.33 339 13.33 339 13.33 339 13.33 339 9.38 238 9.38 238 9.38 238 9.38 238 9.38 238 1.64 42 1.64 42 1.64 42 1.64 42 1.64 42 Min.–Max. 9.12–19.25 232 489 9.12–19.25 232 489 9.12–19.25 232 489 9.12–19.25 232 489 9.12–19.25 232 489 E F 2.33 59 2.33 59 2.33 59 2.33 59 2.33 59 8.00 203 8.00 203 8.00 203 8.00 203 8.00 203 G H — 0.09 3 0.09 3 0.09 3 0.09 3 J K L M — — — — 6.50 165 6.50 165 6.50 165 6.50 165 6.50 165 9.53 242 2.77 70 4.14 105 6.64 169 2.77 70 9.44 240 9.44 240 9.44 240 9.44 240 9.44 240 — 14.11 358 15.48 393 17.98 457 18.53 471 — — — — — 9.53 242 N P Q R S T — — — 9.63 245 9.63 245 9.63 245 9.63 245 3.14 80 3.14 80 3.14 80 3.14 80 3.14 80 1.03 26 1.03 26 1.03 26 1.03 26 1.03 26 0.75 19 0.75 19 0.75 19 0.75 19 0.75 19 — — — The dimensions shown may be extended 7” by utilizing 9422 R2 (two required per switch). L A T R B C K B = Minimum to wall or barrier, right or left hand mounting to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10. E S S F F M N G Vertical CL Flange Mt’d Oper. Mech. 100 A – For (4) 1/4-20 Tap H 200 A – For (4) 5/16 -18 Tap B 200 A 100 A Enclosure Flange (2) 1/4-20 Tap Enclosure Door Q P Dt Distance from outside of flange to disconnect switch mounting surface. 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES 8-18 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Disconnect Switches Flange Mounted, Variable Depth Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us Disconnect Switches—400 A Type TG Outline Dimensions and General Location, 400 A Disconnect Switches Non-Fusible and Non-Interchangeable Fuse Clip Type Fusible Switches Table 8.66: Handle Mechanism—Type A5 through A8 NOTE: Commercially available enclosures may not accept type TG operating mechanisms. Contact the enclosure manufacturer for availability of enclosures for use with these switches. 3.75 Max. 1.44 95 "On" 37 Enclosure Flange Switch Type B X TG1, 2 11.28 286 16.06 408 3.00 76 13.00 11.50 330 B X 292 11.69 Note: B and X = Minimum to wall or barrier to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430.10. 297 1.88 48 4.78 121 1.50 0.75 4.88 38 124 19 24.00 610 0.38 10 4.25 Operating Link 0.50 108 13 8.50 216 CL of Operating Handle CL of Operating Mechanism Door Hook 9.88 251 191 23.81 605 Door (2) 0.34 Dia. 9 Holes (2) Switch Mtg. Brackets Defeater Guide for Class 9423 Type M1 Kit Figure 2 3.63 92 (2) Mtg. Holes in Switch Mtg. Surface Figure 1 D30064-973 B Figure 3 Non-fusible and Fusible Switches *D 5.50 140 1.86 Dimension D = Distance from outside of flange to disconnect switch mounting surface. 12.14 36 For Type TG1 or TG2 with: Type A5 or A6 fixed depth handle mechanism Type A7 or A8 adjustable depth handle mechanism Weld 13.54 1.40 47 In steps of 344 308 D= D= 11.38 289 15.87 403 0.63 16 15 to 22 B 19 483 C L of Operating Mechanism Note: Copper lugs are standard on all Type TG disconnect switches. 23.80 25.00 604 24.00 0.86 0.60 635 * D = Mounting depth measured from the switch mounting surface to the surface of flange. 610 8.38 213 6.97 177 3.97 Weld OPERATOR MECHANISMS AND DISCONNECT SWITCHES Table 8.67: 7.50 101 Class J Fuse 400 A 600 Volt 8.13 206 Class H, K, R Fuses 400 A 250 Volt Class H, K, R Fuses 400 A 600 Volt Figure 4 Enclosure Provision for (2) 5/16 Mtg. Screws Figure 5 in. mm 8 Dim. = © 2009 Schneider Electric All Rights Reserved 8-19 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket Mounted Disconnect Devices Type T Disconnect Switches Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us The Class 9422 Type T disconnect switches listed in the table below are shipped with the switch and external handle assembled to a bracket, ready for installation into the enclosure. A trim plate is provided with each kit to Table 8.68: prevent any mounting screws from being accessible from the front and also to provide an attractive installation.These switches can be used with Class 9423 door closing mechanisms. Bracket Mounted Disconnect Switches Maximum Horsepower Rating Disconnect Switch Size 208 (200) 240 (230) 480 (480) 250 Vdc 600 (600) Fuse Type None 30 A 7.5 7.5 15 20 5 H, K, J, R Ja None 60 A 15 15 30 Bracketed Mounted Switch Mechanism and Handle Fuse Clip Rating AC System Volts (Motor Voltage) 50 10 100 A 25 30 60 75 20 200 A 40 60 125 150 40 a Space saving design—Type J fuses mounted on the non-fused bracket. Note: For Lug Data, see 8-17; for Electrical Interlocks, see page 8-16. H, K, J, R Ja None H, K, J, R Ja None H, K, J, R J 250 V (A) — 30 60 60 — 60 — — — 100 100 — 200 — 600 V (A) — — 30 30 — 30 60 60 — 100 100 — 200 400 Catalog No. $ Price BTCN30 BTCF30 BTCF33 BTCF32 BTDN60 BTDF60 BTDF63 BTDF62 BTEN10 BTEF10 BTEF11 TFB1 TFB2 TFB3 471.00 543.00 543.00 543.00 527.00 585.00 629.00 629.00 714.00 926.00 926.00 1488.00 1610.00 2264.00 Note: Some enclosures may not accept the listed bracket mounted operating mechanisms; contact the enclosure manufacturer. Table 8.69: Bracket Mounted Operating Mechanisms for Use With Square D® Circuit Breakers The circuit breaker operating mechanisms listed below are shipped with the external operating handle assembled to a bracket. Circuit breakers are not included and must be ordered separately. A trim plate is provided with each kit to prevent any mounting screws from being accessible from the front and also to provide an attractive installation.The operating handle is Type A1. These switches can be used with Class 9423 door closing mechanisms. Operating Mechanism Use With Circuit Breaker or Interrupter Type No. of Poles Right Hand Flange Mounting Frame Size (A) Cat. No. $ Price FAL, FHL 2–3 100 BN1 257.00 KAL, KHL 2–3 250 BP1 270.00 LALa, LHLa, Q4L 2–3 400 BR1 543.00 a Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. Table 8.70: Electrical Interlock Kits—Class 9999 Optional accessory for use with circuit breaker operating mechanisms listed to the left and the flexible cable mechanisms listed below, except GJL. Description Class Type $ Price Single Pole, Double Throw Double Pole, Double Throw 9999 9999 R26 R27 131.00 243.00 Note: Not used with GJL; use field installed circuit breaker interlocks. Note: Some enclosures may not accept the listed bracket mounted operating mechanisms; contact the enclosure manufacturer. Table 8.71: Type D Disconnect Device Dimensions A in. (mm) C in. (mm) D in. (mm) Min. Enclosure Deptha in. (mm) Fusible Device E in. (mm) — 11.88 (302) — 20.00b(508) BTCN, BTDN, BTEN 6.56 (167) 8.00 (203) BTCF, BTDF, BTEF 9.50 (241) 1.88 (48) 8.56 (217) 10.00 (254) 6.38 (162) TFB1 11.50 (292) 3.88 (99) 9.50 (241) 12.00 (305) 13.19 (335) TFB2, TFB3 20.00 (508) BG1, BN1 8.75 (222) 7.13 (181) 1.13 (29) 6.50 (165) 8.00 (203) BP1 9.13 (232) 7.38 (187) a The minimum enclosure depth is greater than Dimension D since additional space is needed when mounting the mechanism. b Fuses and fuse base assembly do not extend beyond bracket. Note: Back panel support is recommended for Types TFB1, 2, & 3. Other devices may also require support if the flange is not sufficiently rigid. Table 8.72: 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES Circuit Breaker Type Class 9422—Flexible Cable Mechanisms for Use With Square D Circuit Breakers No. of Poles Frame Size (A) CP1 Discount Schedule F 10 C 0.38 10 Disconnect Device ON A E OFF 0.38 10 Non Fused and Circuit Breaker Fused (2) 0.38 Dia. Mounting Holes 10 (For back panel support if necessary.) For use with Square D circuit breakers and Class 9422 A handle operators. Especially designed for tall, deep enclosures where placement flexibility is required. See page 8-21 for dimensions. Cable Mechanism Cable Length Catalog No. $ Price 36 in. CGJ30 273.00 48 in. CGJ40 291.00 GJL 3 100 60 in. CGJ50 291.00 120 in. CGJ10 333.00 36 in. CFA30 273.00 FAL, FHL 2-3 100 60 in. CFA50 291.00 120 in. CFA10 333.00 36 in. CKA30 288.00 KAL, KHL 2-3 250 60 in. CKA50 305.00 120 in. CKA10 347.00 36 in. CLA30 486.00 LALa, LHLa, Q4L 2-3 400 60 in. CLA50 504.00 120 in. CLA10 548.00 a Note: These operating mechanisms cannot be used with any LA/LH circuit breaker with an MB or MT suffix. 8-20 0.38 F in. (mm) Cable Mechanisms with A1 Handle For Types 1, 3, 3R, 4, 12 Catalog No. CGJ31 CGJ41 CGJ51 CGJ11 CFA31 CFA51 CFA11 CKA31 CKA51 CKA11 CLA31 CLA51 CLA11 $ Price 417.00 432.00 432.00 476.00 417.00 432.00 476.00 431.00 446.00 489.00 630.00 647.00 689.00 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Flexible Cable Mechanisms For Circuit Breakers Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us X C Refer to NEC Article 430-10 for minimum dimension X from circuit breaker top mounting hole to wall or barrier to ensure adequate wire bending space. 1.00 A 25 E B 4.69 119 9.12 Table 8.73: Flexible Cable Mechanisms for Use with Schneider Electric® (formerly Merlin Gerin®) and PowerPact® 3-Pole Circuit Breakers For use with Class 9422 A handle operators especially designed for tall, deep enclosures where placement flexibility is required. Circuit Breaker Type No. of Poles Cable Mechanism Frame Size A Length Type $ Price 36 in. 60 in. 84 in. 120 in. 36 in. 60 in. 120 in. 36 in. 60 in. 120 in. 36 in. 60 in. 120 in. 36 in. 50 in. 120 in. CSF30 CSF50 CSF70 CSF10 CSF304 CSF504 CSF104 CSJ30 CSJ50 CSJ10 CSJ304 CSJ504 CSJ104 CMP40 CMP50 CMP10 288.00 305.00 323.00 347.00 297.00 314.00 356.00 486.00 504.00 548.00 500.00 516.00 558.00 759.00 785.00 857.00 232 D MG-NSF PowerPact H- and J-Frame 2-3 250 MG-NSF 4 250 MG-NSJ PowerPact D 3 600 MG-NSJ PowerPact D 4 600 PowerPact M- and P-Frame 3 1200 1.44 37 4.25 108 Note: Bend radius in cable must never be less than 6 inches. Electrical clearances must be maintained between cable and live electrical parts. Table 8.74: Cable Operating Mechanisms for Circuit Breakers—Dimensions A Type CGJ CFA CKA CLA CSF 3-Pole CSF 4-Pole CSJ 3-Pole CSJ 4-Pole CMP Table 8.75: Class B C D E in. mm in. mm in. mm in. mm in. mm 3.50 4.26 4.94 6.00 5.85 5.85 4.13 4.13 8.744 89 108 125 152 149 149 105 105 222 5.25 8.50 10.13 11.00 7.97 7.97 9.50 9.50 15.00 133 216 257 279 202 202 241 241 381 2.50 3.75 3.75 3.75 3.50 3.50 3.00 3.00 2.38 63 95 95 95 89 89 76 76 60 3.75 6.75 7.13 10.19 4.84 8.08 7.25 9.03 12.41 95 171 181 259 123 205 183 229 315 5.25 8.50 10.13 11.00 7.97 7.97 9.50 9.50 15.00 133 216 257 279 202 202 241 241 381 Class 9999 Auxiliary Contact Kits for Disconnect Switches and Circuit Breakers Type Disconnect Switches 9422 BTCF, BTCN, BTDF, BTEF, BTEN 9422 TCF, TCN, TDF, TDN, TEF, TEN 9422 TF Circuit Breaker Operating Mechanisms 9421 LF, LK, LL, LM, LN, LP, LR, LT, LW 9422 RM, RN, RP, RQ, RR, RT 9422 CFA, CKA, CLA, CSF, CMP SPDT DPDT Type $ Price Type $ Price TC11 TC10 R8 120.00 120.00 87.00 TC21 TC11 R9 239.00 239.00 243.00 R47 R26 R26 131.00 131.00 131.00 R48 R27 R27 221.00 243.00 243.00 NOTE: No external auxiliary contacts are available for the following circuit breakers: GJL circuit breakers must use internal catalog No. AAC. PowerPact D circuit breakers must use internal catalog No. AAC. 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES For additional variations, contact CIC at 1-888-SQUARE D (1-888-778-2733). © 2009 Schneider Electric All Rights Reserved CP1 Discount Schedule 8-21 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Flexible Cable Mechanisms For Circuit Breakers Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us Dual Cable Operating Mechanisms for Square D® Circuit Breakers Dual Cable Operator Mechanisms are designed for use with Square D GJL and PowerPact® D, H, and J circuit breakers through 600 A frame sizes. The cable mechanisms allow for a single handle operator, Class 9422A1, to operate both circuit breakers. The cable mechanism is designed especially for tall, deep enclosures where placement flexibility is required. There are numerous cable arrangements to choose from to accommodate many applications. Features • • • • • Separate cables for each circuit breaker Rugged metal flange handle operator Maximized flexibility of circuit breaker placement for existing and new applications Control panel can be fed from two separate supply voltages (if required) Dual mechanism allows both separate supply voltages to be controlled by a single handle to improve security features Table 8.76: Dual Cable Operating Mechanisms Selection Circuit Breaker Type GJL PowerPact H & J MG NSF PowerPact D MG NSJ Table 8.77: Cable Length in. / mm (quantity) 36 in. / 914 mm (2) 48 in. / 1219 mm (2) 60 in. / 1524 mm (2) 120 in. / 3048 mm (2) 36 in. / 914 mm (1) 60 in. / 1524 mm (1) 60 in. / 1524 mm (1) 120 in. / 3048 mm (1) 120 in. / 3048 mm (2) 36 in. / 914 mm (1) 60 in. / 1524 mm (1) 60 in. / 1524 mm (1-CSF 3 pole) 60 in. / 1524 mm (1-CSF 4 pole) 120 in. / 3048 mm (1-CSF) & 120 in. / 3048 mm (1-CSJ) 36 in. / 914 mm (1-CSF) & 36 in. / 914 mm (1-CSJ) 60 in. / 1524 mm (1-CSF) 60 in. / 1524 mm (1-CSJ) Catalog Number 9422CGJD3 9422CGJD4 9422CGJD5 9422CGJD1 Frame Size (max.) $ Price 100 A 585.00 608.00 675.00 788.00 9422CGJD8 642.00 9422CGJD9 720.00 9422CSFD1 693.00 9422CSFD35 250 A 9422CSFD345 672.00 9422CSFJD10 9422CSFJD30 648.00 894.00 250 A & 600 A 9422CSFJD50 774.00 809.00 Special Left-hand Mounted Single Cable Operating Mechanisms Circuit Breaker Type FAL Cable Length in. / mm (quantity) 120 in. / 3048 mm (1) 36 in. / 914 mm (1) 60 in. / 1524 mm (1) Catalog Number Frame Size (max.) $ Price 9422CFAL10 9422CFAL30 9422CFAL50 100 A 350.00 287.00 318.00 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES 8-22 CP1 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Disconnect Switch Accessories Flange Mounted, Variable Depth Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us Designed for installation in custom built control enclosures where main or branch circuit protective devices are required. All circuit breaker operating mechanisms are suitable for either right- or left-hand flange mounting, convertible on the job. Table 8.78: Variable Depth Mechanisms for Use with Square D® and Schneider Electric® (formerly Merlin Gerin®) Circuit Breakers Use with Circuit Breaker Frame Size No. of Poles Operating Mechanism Variable Depth Mtg. Range Min.-Max.a (Inches) Frame Size A Operating Mechanism Only—Does Not Include Handle Mechanism Operating Mechanism and Handle Mechanism Includes Type A1 Handle Mechanism Includes Type A2 Handle Mechanism Type $ Price Type $ Price Type $ Price RG1 RN1 RP1 RR1 RT1 RT1 RX1 116.00 116.00 129.00 329.00 449.00 449.00 513.00 ARG11 ARN11 ARP11 ARR11 ART11 ART11 — 257.00 257.00 270.00 471.00 593.00 593.00 — ARG21 ARN21 ARP21 ARR21 ART21 ART21 — 372.00 372.00 386.00 585.00 705.00 705.00 — Square D Circuit Breakers GJL FAL, FHL KAL, KHL LALc, LHLc, Q4L MEL, MXL MAL, MHL NAL, NCL, NEL, NXL 3 2–3 2–3 2–3 2–3 2–3 2–3 100 100 250 400 800 1200 1200 6.00–17.75 5.38–17.75 6.38–17.88 7.44–18.25 9.00–18.38 9.00–18.38 11.00–18.37 Schneider Electric (formerly Merlin Gerin) and PowerPact® Frame 3-Pole Circuit Breakers MG-NSF PowerPact 2–3 250 5.88–17.75 RQ1 185.00 H- and J-Frame MG-NSJ 3 600 9.00–17.75 RS1 383.00 PowerPact D PowerPact 3 1200 9.00–18.38 RM1 513.00 M- and P-Frame a Class 9422 Type R2 will extend mounting depth 7 inches (see page 8-24). — — — — — — — — — — Electrical Interlocks—Class 9999 Description Class Single Pole, Double Throw 9999 Double Pole, Double Throw 9999 a Not for use with the GJL operating mechanism. Table 8.80: — Type R26a R27a $ Price 131.00 243.00 Dimensions Circuit Breaker Frame Size Width (A) Type in. Height (B) mm in. mm Distance to Enclosure Flangea (C) Minimum in. mm Maximum in. mm Bracket Depth (D) in. mm GJL RG1 5.00 127 4.75 121 6.00 152 17.75 451 4.00 FAL, FHL RN1 6.75 171 8.50 216 5.51 140 17.75 451 4.26 KAL, KHL RP1 7.13 181 10.13 257 6.51 165 17.88 454 4.94 LALc, LHLc, Q4L RR1 10.19 259 11.00 279 7.44 189 18.25 464 6.00 MEL, MXL RT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 MAL, MHLb RT1 13.38 340 14.00 356 9.00 229 18.38 467 9.69 NAL, NCL, NEL, NXL RX1 19.63 499 13.50 343 11.00 279 18.37 467 9.00 MG-NSF RQ 4.84 123 7.97 203 5.875 149 17.75 451 5.62 MG-NSJ RS 9.27 236 9.5 241 9.0 228 17.75 451 5.73 PowerPact M & P RM 12.29 312 15 381 10.5 267 18.9 480 8.73 a 9422 R2 will extend dimension 7 in. Two required. b Minimum mounting depth when using MAL or MHL circuit breakers can be decreased to 7.63 inches by using the Class 9422 Type RT1B conversion kit. $23.00 c Warning: These operating mechanisms cannot be used with any LA / LH circuit breaker with an MB or MT suffix. C = Distance from Outside of Flange to Circuit Breaker Mounting Surface Enclosure Door Enclosure Flange D Minimum to wall or barrier. Right or left hand mounting to insure adequate wire bending space to lug surface when maximum wire size is used. Refer to NEC Article 430-10. B 8 CL R.H. Handle A CL L.H. Handle 102 108 125 152 246 246 229 143 146 222 OPERATOR MECHANISMS AND DISCONNECT SWITCHES Table 8.79: — © 2009 Schneider Electric All Rights Reserved CP1 Discount Schedule 8-23 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Disconnect Switches Flange Mounted, Variable Depth Disconnect Switch Accessories Class 9422 / Refer to Catalog 9420CT9701 www.schneider-electric.us Remote or Dual Adapter Kit Switch or Breaker For the remote or dual operation of 30, 60, 100 and 200 A disconnect switches, or GJL, FAL, FHL, KAL, KHL, LAL, LHL, Q4L, MAL, MHL, MEL and MXL circuit breakers. Remote Operation—permits mounting the Class 9422 Type A9 or A10 handle mechanism at a lower level than the disconnect device it controls. This arrangement is often required where the disconnect device is mounted too high for personnel to easily reach a conventional operator. Dual Operation—permits controlling two disconnect devices, one in line with and one remote from a single Class 9422 Type A9 or A10 handle mechanism. NOTE: A Class 9422 Type A9 or A10 handle (page 8-17) and the preferred mounting method must be used. Table 8.81: Disconnect Device Disconnect Device Remote operation shown (handle mechanism not included in kit) Disconnect Switch 30 A Type TCF/TCN 60 A Type TDF/TDN 100 A Type TEF/TEN 200 A Type TF Circuit Breaker GJL FAL, FHL KAL, KHL LAL, LHL, Q4L MAL, MHL,MEL, MXL Table 8.82: Enclosure Mounting Depth Min. Max. 10.63 10.63 12.13 13.13 19.50 19.50 20.25 20.81 10.50 10.66 11.13 12.13 13.75 19.50 19.50 19.50 19.88 20.25 Type $ Price D2 251.00 Air Valve Interlock Note that air valve interlocks only accept the specific three-way air valves, manufactured by Parker, listed in the table below. Parker Valve Model Numbera Air Valve Size Knob Operated M04841885 M08541848 M04861885 M08561848 0.50 NPT 13 Air valve interlock mounted on enclosure a Alternate Mounting Kit Channel/Flange Support Kit Auxiliary Lock Plate Special Lugs for Disconnect Switches 8 Operating Rods OPERATOR MECHANISMS AND DISCONNECT SWITCHES Auxiliary Lock Plate 8-24 $ Price G1 513.00 Other Accessories Accessory Channel/Flange Support Kit Type 0.75 NPT G2 513.00 19 1.00 NPT M00080004 G1 513.00 25 Prices do not include air valves or handle mechanism. For more information on air valves listed above contact Parker at C-PARKER@PARKER.COM, or call 1-800-272-7537. Table 8.83: Alternate Mounting Kit Class 9422 Air Valve Interlock Description Permits mounting Class 9422 Type A1 or A2 handle mechanisms in enclosures with flange thickness of 16 gauge to 0.5 in. Auxiliary kit recommended for use with 30 and 60 A disconnect switches and FAL, FCL, FHL, KAL KHL, NSF and NSJ circuit breaker mechanisms when these devices are to be mounted on the center channel of a multi-door enclosure or when extra rigidity for the flange is required. Supplied as standard with 100 and 200 A disconnect switches and LAL, LHL, Q4L, MAL, MHL, MEL and MXL circuit breaker mechanisms. Auxiliary kit recommended for use with the Class 9422 Type A-1 flange handle to facilitate padlocking the handle in the “OFF” position. Primarily used when the handle is mounted on the center channel of a multi-door enclosure. Also in any case where the enclosure doors interfere with the normal padlock slot in the flange handle. Meets both the Automotive and NFPA 79 specifications. Copper Lugs only—Specify Form Y157 Tin Plated Aluminum Lugs for 400 A Type TG Switch—Specify Form Y1572 (000–750 kcmil Cu/Al wire) Anderson Type VCEL Compression Lugs—Specify Form Y1574 Exceptions: None of the 30 A or 60 A disconnect switches are available with compression lugs. Standard operating rod for use with Class 9422 variable depth mechanisms. Included as standard in each kit. Extra long operating rod for use with Class 9422 variable depth mechanisms. Can be used as a substitute for the standard rod included in each kit to increase the maximum mounting depth 7 in. (Two are required for Types ARR, RR, ART, RT, ATE, TE, ATF, TF). CP1 Discount Schedule Class Type $ Price 9422 AM2 14.30 9422 C1 42.80 9422 L1 36.00 — — No Charge — — No Charge — — No Charge 9422 R1 28.70 9422 R2 50.00 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Door Closing Mechanisms Introduction Class 9423 / Refer to Catalog 9420CT9701 www.schneider-electric.us Class 9423 door closing mechanisms cover a range of enclosures with up to 91 inch high maximum door openings. The door closing mechanisms are designed to be used on control enclosures and interlocked with a Class 9422 disconnect device, although they all can be used independently. Three different systems are available and their use is as recommended below. A complete system is available for interlocking all the doors of a multi-door enclosure with the master door when using the 6 in. or 8 in. vault handle mechanism. Note that the “Master Door” is defined to be the door of a single or multi-door enclosure which is interlocked directly with the disconnect device. The master door can be hinged on either the right or left hand side. It can be located in any position on a multi-door enclosure. On the other hand, an “Auxiliary Door” is defined to be any remaining doors of a multi-door enclosure which are interlocked with the master door by means of the overhead interlocking system as illustrated on pages 8-26 and 8-27. Selection Procedure 9422 TCN30 Step 1. Determine enclosure construction (number of doors, door height, hinge location, etc.). Step 2. Determine Class 9422 disconnect device to be used—either a disconnect switch or a circuit breaker mechanism. Step 3. Determine the location of the disconnect device and handle mechanism (right or left hand flange or center channel). Step 4. Select the door closing mechanism required. Step 5. Select the auxiliary door closing mechanisms and multi-door interlocking hardware, if required. (A complete system for interlocking all auxiliary doors of a multi-door enclosure with center channel is available for the medium and large enclosures.) Table 8.84: Door Closing Mechanism 60 in. Maximum Door Opening (Recommended) Circuit Breaker Mechanism • • • 46–60 in. Door Opening (Recommended) • 2 Point Locking is Standard A Third Roller Latch Kit is Available for 3 Point Locking For 3/4 in. Door Depths • • • 61–91 in. Door Opening (Recommended) • For use on Single or Multi-Door Enclosures For use with Doors Hinged on Right or Left Side Referred to as the 6 in. Vault Handle Mechanism For 3/4 in. Door Depths • • • For use on Single or Multi-Door Enclosures For use with Doors Hinged on Right or Left Side Referred to as the 8 in. Vault Handle Mechanism For 1-1/8 in. Door Depths Description Two point, roller latch, door closing mechanism for use on enclosures with doors hinged on the left hand side. Type M4 Use In Conjunction With NEMA Type 4 and 12 Sheet Steel NEMA Type 4 and 12 Stainless Steel NEMA Type 4 and 12 Sheet Steel Door Latch Handle Length Suggested Maximum Door Opening Door Depth Type $ Price Class 9422 Types A1, A3, A9 4 in. 4 in. 6 in. Less than 39 in. Less than 39 in. 60 in. a M4 M10 M9 228.00 314.00 243.00 Class 9422 Types A2, A4, A10 4 in. Less than 39 in. M24 300.00 Class 9422 Types A1, A3, A9 4 in. 4 in. 6 in. Less than 39 in. Less than 39 in. 60 in. M4L M10L M9L 228.00 314.00 243.00 4 in. Less than 39 in. M24L 300.00 — — M3 50.00 — — M23 57.00 NEMA Type 4 and 12 Stainless Steel Class 9422 Types A2, A4, A10 Class 9423 NEMA Type 4 and 12 Third roller latch kit for 3 Types M4, M9, Sheet Steel point locking; for use where M4L, M9L 3 point locking is desired or Class 9423 where the door opening is NEMA Type 4 and 12 Types M24, 39 in. or more. Stainless Steel M24L a Suitable for door depths of 1-1/8 in., 1-1/4 in., 1-3/8 in. and 1-1/2 in.. a 8 Latch bar not included, but most prepunched enclosures that accept Square D® operating mechanisms supply a predrilled latch bar. Two point, roller latch, door closing mechanism for use on enclosures with doors hinged on the right hand side. For Use On (Enclosure Type) OPERATOR MECHANISMS AND DISCONNECT SWITCHES The door closing mechanisms listed below are for use on small to medium size single door control enclosures. They are designed to be used in conjunction with Class 9422 flange mounted disconnect switches and circuit breaker operating mechanisms; however, they can be used independently as well. When used on properly designed and gasketed NEMA Type 12 enclosures, they meet NFPA 79 standards. Table 8.85: Single Door Enclosures—NEMA Type 4 or 12 with 60 in. High Maximum Opening © 2009 Schneider Electric All Rights Reserved CP1 Discount Schedule 8-25 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Door Closing Mechanisms Types M5, M6, M1, and M8 Class 9423 / Refer to Catalog 9420CT9701 www.schneider-electric.us Vault Type for Single and Multi-Door Enclosures Table 8.86: Table 8.86 shows the requirements for the door closing mechanism, the locking bar kit, and the mechanical interlock kit, if used. Single or Multi-Door Enclosures—NEMA Type 12 with 40 in. to 60 in. Door Opening Single-Door Enclosure Multi-Door Enclosure Without Interlocking With Interlocking Without Interlocking With Interlocking 1—M6 door closing mechanism 1—Type M660 locking bar kit 1—M6 door closing mechanism 1—Type M660 locking bar kit 1—Type M5 (use with 9422A handles) For each door: 1—M6 door closing mechanism 1—Type M660 locking bar kit For Master door: 1—M6 door closing mechanism 1—Type M660 locking bar kit 1—Type M5 (for use with 9422A handles) NOTE: All mechanisms listed on this page are suitable for either left or right hand mounting. View from Inside the Enclosure Table 8.87: 1/4" Dia. Rod (Supplied By User) Locking Bar Locking Bar A B Door Opening C Auxiliary Door Type M6 Type M5 Door Interlocks Type M6 Door Closing Mechanism The Class 9423 Type M6 door closing mechanism is designed to close and seal 0.75 in. deep doors of single or multi-door NEMA Type 12 enclosures. The Type M6 can be used on doors hinged on either the left or right hand side. Recommended door openings are from 40–60 in. Vault type handle length is 6 in. Type M660 Locking Bar Kits The lock bar kit for the Type M6 door closing mechanism contains two lock bars and is available from stock. The bars can be cut to fit door openings through 60 in. One lock bar kit is required for each Type M6 ordered. Type M5 The Class 9423 Type M5 mechanical interlock kit is designed to interlock a Class 9422 handle mechanism with the Type M6 door closing mechanism. This kit prevents opening the master door (or single door) with the disconnect handle in the “ON” position, making it mandatory to use a screwdriver to gain entry to the enclosure at any time, regardless of the disconnect handle position. Table 8.88: Locking Bar For each Auxiliary door: 1—M6 door closing mechanism 1—Type M660 locking bar kit Necessary quantities of Types M2 and M7 for each door (see below) 257.00 86.00 215.00 Required Accessories for Auxiliary Doors Type M2 One Type M2 kit is required for each auxiliary door. This kit is required to interlock any auxiliary door(s) with the master door. Type M7 The first auxiliary door requires 2 Type M7 kits. Additional auxiliary doors require only 1 Type M7 kit. The 0.25 in. diameter rod used to interconnect the M7 kits is furnished by the user. If the distance between any two Type M7 kits exceeds 36 in., an additional Type M7 kit should be installed to prevent the rod from buckling. Locking Bar $ Price $ Price 257.00 71.00 Master Door (Single Door) Type M7 Type M2 Note: A - Interlocking lever extension of the flange mounted handle mechanism. Note: B - Actual enclosure opening—not door height. Note: C - Screwdriver interlock assembly can be ordered separately. Class 9423 Type CEQ2493. $45.00 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES 8-26 CP1 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Door Closing Mechanisms For Single and Multi-Door Enclosures Class 9423 / Refer to Catalog 9420CT9701 www.schneider-electric.us Vault Type for Single and Multi-Door Enclosures Table 8.89 shows the requirements for the door closing mechanism, the locking bar kit, and the mechanical interlock kit, if used. Table 8.89: Single Or Multi-Door Enclosures—NEMA Type 12 with 61 in. to 91 in. Door Openings Single-Door Enclosure Without Interlocking 1—M8 door closing mechanism 1—Type M891 locking bar kit Multi-Door Enclosure With Interlocking Without Interlocking 1—M8 door closing mechanism For each door: 1—Type M891 locking bar kit 1—M8 door closing mechanism 1—Type M1 (for use with 9422A handles) 1—Type M891 locking bar kit NOTE: All mechanisms listed on this page are suitable for either left or right hand mounting. View from Inside the Enclosure Table 8.90: 1/4" Dia. Rod (supplied by user) Locking Bar Locking Bar With Interlocking For each Auxiliary door: 1—M8 door closing mechanism 1—Type M891 locking bar kit Necessary quantities of Types M2 and M7 for each door (see below) For Master door: 1—M8 door closing mechanism 1—Type M891 locking bar kit 1—Type M1 (for use with 9422A handles) A B Door Opening Table 8.91: Auxiliary Door Type M8 Type M1 Locking Bar $ Price 500.00 86.00 428.00 Required Accessories for Auxiliary Doors Type M2 One Type M2 kit is required for each auxiliary door. This kit is required to interlock any auxiliary door(s) with the master door. Type M7 The first auxiliary door requires 2 Type M7 kits. Additional auxiliary doors require only 1 Type M7 kit. The 0.25 in. diameter rod used to interconnect the M7 kits is furnished by the user. If the distance between any two Type M7 kits exceeds 36 in., an additional Type M7 kit should be installed to prevent the rod from buckling. C Locking Bar Door Interlocks Type M8 Door Closing Mechanism The Class 9423 Type M8 door closing mechanism is designed to close and seal 1.125 in. deep doors of single or multi-door NEMA Type 12 enclosures. The Type M8 can be used on doors hinged on either the left or right hand side. Recommended door openings are from 61–91 in. Vault type handle length is 8 in. Type M891 Locking Bar Kits The lock bar kit for the Type M8 door closing mechanism contains two lock bars and is available from stock. The bars can be cut to fit door openings through 91 in.. One lock bar kit is required for each Type M8 ordered. Type M1 The Class 9423 Type M1 mechanical interlock kit is designed to interlock a Class 9422 handle mechanism with the Type M8 door closing mechanism. This kit prevents opening the master door (or single door) with the disconnect handle in the “ON” position, making it mandatory to use a screwdriver to gain entry to the enclosure at any time, regardless of the disconnect handle position. $ Price 257.00 71.00 Master Door (Single Door) Type M7 Type M2 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES Note: A - Interlocking lever extension of the flange mounted handle mechanism. Note: B - Actual enclosure opening—not door height. Note: C - Screwdriver interlock assembly can be ordered separately. Class 9423 Type CEQ2493. $45.00 © 2009 Schneider Electric All Rights Reserved CP1 Discount Schedule 8-27 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Door Closing Mechanisms Types M5, M6, M1 and M8 Class 9423 / Refer to Catalog 9420CT9701 www.schneider-electric.us Reference 0.25 2.25 Minimum 57 1.50 6 Enclosure Construction and General Location Information For Types M5 and M6 38 A Enclosure Door Enclosure B Door Opening Recommended 40 Inches Minimum 60 Inches Maximum C 0.2 Dia. 17.69 Minimum 5 0.33 Dia. 8 0.69 18 Flange Drilling See Class 9422 Digest Section 449 33.69 Minimum 1.63 856 41 2.00 0.7 Dia. 2.63 18 67 CL of Door 0.88 Dia. 22 0.2 5 Dia. (2 Holes) Reference 0.50 Disconnect Device TCF, TCN, TDF, TDN, TD If A = 1 Minimum B = If A = 4½ Minimum B = C 60 A Disconnect Switch 3-/16 2-1/2 3-3/16 TE, TEF, TEN 100 A Disconnect Switch 5-1/4 2-1/2 3-3/16 TF 200 A Disconnect Switch 11-5/8 8-1/8 3-3/16 TG 400 A Disconnect Switch 15-1/16 11-9/16 6-3/4 RN1 FAL, FHL, Circuit Breaker 4-27/32 2-1/2 3-3/16 RP1 KAL, KHL Circuit Breaker 11-5/32 7-21/32 3-3/16 RR2 ILL Circuit Breaker 17-31/32 14-15/32 3-3/16 RT1 MAL, MHL, MEL, MXL Circuit Breaker 18-5/8 15-1/8 3-3/16 38 Enclosure Door Enclosure B Door Opening Recommended 61 Inches Minimum 91 Inches Maximum C 0.2 Dia. 5 18 Type 76 A 0.33 Dia. 8 0.69 Dimension B (Minimums) 3.00 Minimum 1.50 13 Single door enclosures: A minimum = 1 in. Multi-Door enclosures without overhead interlocking system: A minimum = 1 in. Multi-Door enclosures with overhead interlocking system: A minimum = 4½ in. Overhead interlocking system consists of the required number of Class 9423 Type M2 and M7 kits for interlocking the auxiliary doors with the master door. See page 8-26. Table 8.92: 94 89 Note: Note: Note: Note: 25 71 3.69 3.50 Dimension A 1.00 2.81 51 Drilling and location information below is complete for a single door enclosure with door hinged on left side, incorporating a Type M6, M5, and Class 9422 handle mechanism. Transpose all horizontal dimensions for doors hinged on right side. 449 3.75 64 95 1.00 25 4.75 121 89 0.7 Dia. 18 Dimension A 2.25 Note: Note: Note: Note: 57 CL of Door +.010 -.000 1.00 Dia. 25 Drilling and location information below is complete for a single door enclosure with the door hinged on the left side, incorporating a Type M8, M1, and Class 9422 handle mechanism. Transpose all horizontal dimensions for doors hinged on the right side. 856 48 2.50 Enclosure Construction and General Location Information For Types M1 and M8 17.69 Minimum 33.69 Minimum 1.88 3.50 Flange Drilling See Class 9422 Digest Section Single door enclosures: A minimum = 1½ in. Multi-Door enclosures without overhead interlocking system: A minimum = 1½ in. Multi-Door enclosures with overhead interlocking system: A minimum = 4½ in. Overhead interlocking system consists of the required number of Class 9423 Type M2 and M7 kits for interlocking the auxiliary doors with the master door. See page 8-27. Table 8.93: 0.2 5 Dia. (2 Holes) Dimension B (Minimums) Disconnect Device Type TCF, TCN, TDF, TDN, TD 60 A Disconnect Switch 8 OPERATOR MECHANISMS AND DISCONNECT SWITCHES 8-28 If A = 1½ Minimum B = If A = 4½ Minimum B = C 2-15/16 2-1/2 3-3/16 TE, TEF, TEN 100 A Disconnect Switch 4-3/4 2-1/2 3-3/16 TF 200 A Disconnect Switch 11-1/8 8-1/8 3-3/16 TG 400 A Disconnect Switch 14-9/16 11-9/16 5-7/8 RN1 FAL, FHL Circuit Breaker 4-11/32 2-1/2 3-3/16 RP1 KAL, KHL Circuit Breaker 10-21/32 7-21/32 3-3/16 RR2 ILL Circuit Breaker 17-15/32 14-15/32 3-3/16 RT1 MAL, MHL, MEL, MXL Circuit Breaker 18-1/8 15-1/8 3-3/16 CP1 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2009:03:04 15:07:16-06:00 Modify Date : 2009:07:21 11:45:20-07:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Instance ID : uuid:917c3b88-5e42-2142-b87d-db5aa1163295 Document ID : adobe:docid:indd:b9f34800-0a58-11de-94b9-c9f90b55436d Rendition Class : proof:pdf Derived From Instance ID : d77ef6d0-0342-11de-8b2d-ac93865527c8 Derived From Document ID : adobe:docid:indd:59304f5e-032f-11de-8b2d-ac93865527c8 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 72.00, 72.00 Manifest Placed Y Resolution : 300.00, 300.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:96E6D313E0F8DD1193D3A206EA549064, uuid:5B665946E0F8DD1193D3A206EA549064, uuid:4FF6EF6A225911DD91B6E1D8435B5599, uuid:4FF6EF6A225911DD91B6E1D8435B5599 Manifest Reference Document ID : uuid:96CC0F152BCCDD11A7E9FDD05B4D97A8, uuid:4480D645750C11DDA036ECEE5BB6739C, uuid:4FF6EF69225911DD91B6E1D8435B5599, uuid:4FF6EF69225911DD91B6E1D8435B5599 Metadata Date : 2009:07:21 11:45:20-07:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 10674 bytes, use -b option to extract) Format : application/pdf Title : Schneider Electric DIGEST 175 - Operator Mechanisms and Disconnect Switches Creator : Producer : Adobe PDF Library 8.0 Trapped : False Page Layout : SinglePage Page Mode : UseOutlines Page Count : 28EXIF Metadata provided by EXIF.tools