861.qxp 12/16/2013 6:37 PM Page 861 Industrial Lighting Section L Advanced technology, expert support, global certifications, and an unmatched selection of proven solutions combine to deliver superior illumination, increased safety, and the lowest possible cost of ownership. New Products in the Lighting Product Line Section • • • • • • • • • • 2L 2L 2L 2L, 6L 2L 2L, 6L 2L, 6L 2L 2L 2L Hazard•Gard EVLL Series Explosionproof LED Luminaires Hazard•Gard® LPL Series Explosionproof LED Luminaires LL48 Linear LED Luminaires Champ® FMV LED Series Floodlight Fixtures Champ® Pro PVM Series Champ® Pro PFM Series Champ® Pro PFM Series 25L and 50L LED Floodlights Vaporgard™ Pro P2L Series Industrial High Bay LED Series Luminaires Endure™ LED Wall Pack ® Notable changes to the Lighting section of this catalog • Section 3L now contains both hazardous/non-hazardous HID luminaires and induction lighting (previously 3L & 5L) 862-863.qxp 12/16/2013 L 6:38 PM Page 862 Industrial Lighting Table of Contents Section L of the Eaton's Crouse-Hinds Catalog contains information on industrial lighting. Product details on individual luminaires are given in ten separate sections, as noted below. Considerations for Selection Preceding the ten product sections is a Selector Guide. Included in this section is information on: • A selection of the appropriate light source for a given application • A Quick Selector Guide of the luminaires that are designed and approved to meet the various environmental requirements of the National Electric Code • Determining the proper size (i.e., wattage) and number of units to achieve the desired light levels in a given application • Methods to follow in making a luminaire layout. Cat. Nos. are shown, in many cases, for complete assemblies including mounting, reflector, globe, and guard, as well as individual components. In these cases, ordering can be done by component or by complete assembly. Photometric and other technical data is included in each section for the luminaires it contains Information relating to product families in the Lighting Section is shown as follows: Section 1L L Incandescent Lighting (for use in hazardous [classified] and nonhazardous locations) EVI Series Vaporgard™ Series EV Series V Series NDA Corro•Gard™ Series Section 2L LED Luminaires (for use in hazardous [classified] locations, non-hazardous locations, and marine locations) EV LED Series Hazard•Gard® EVLL Series Hazard•Gard LPL Series LL48 Series Champ® VMV LED Series Champ® FMV LED Series Vaporgard™ LED Series N2LPS Light-Pak™ Series Ex-Lite Series CCH UX Series Champ® Pro PVM Series Champ® Pro PFM Series Vaporgard™ Pro P2L Series Industrial High Bay LED Series Endure™ LED Series 862 www.crouse-hinds.com US: 1-866-764-5454 Section 3L Section 7L High Intensity Discharge (H.I.D.) Lighting — Enclosed and Gasketed Luminaire Hangers and Accessories (for use in hazardous [classified] locations, non-hazardous locations, and marine locations) Indoor and outdoor vaportight luminaires for use in applications where dirt, moisture, and corrosion problems exist. Included are units with integral ballasts. Champ® VMV Series Champ® LMV Series Champ® DMV Series VMVIG/DMVIG Series Champ® N2MV Series Champ® NVMV Series Section 4L High Intensity Discharge (H.I.D.) Lighting (for use in hazardous [classified] locations) Indoor and outdoor luminaires and accessories. Included are luminaires with integral ballasts. Hazard•Gard® EVLS Hazard•Gard® EVLP Hazard•Gard® EVM Section 8L Portable Lighting A variety of portable luminaires for hazardous and non-hazardous applications. VS EVH RCDER EVP Section 9L Section 5L Fluorescent Lighting (for use in hazardous [classified] locations and non-hazardous locations) Indoor and outdoor fluorescent luminaires and accessories for application in all classes of hazardous and non-hazardous locations. For hazardous For non-hazardous locations locations CPMVF NFL EVF, EVFDR VF Vaporgard Series FVN, FVS EVFT, DMVF N2MVF, EVLPF VF, eLLK, nLLK eLLB20 Section 6L Floodlights (for use in hazardous [classified] locations and non-hazardous locations) Champ® FMV Series CPMV Champ-Pak™ Wall Pack EVMA-S812 Hazard•Gard® Series F2MV, FMV1000 FZD RCDE SSFMV Voyager nR™ CAN: 1-800-265-0502 (for use in hazardous [classified] locations and non-hazardous locations) A variety of luminaire hangers for use with the luminaires listed. Information on mounting accessories required and typical luminaire weights also included. For hazardous For non-hazardous locations locations EAHC, EFHC AL EC AHG EFH ARB GUA, GUF FHM UNR UNE, UNH, UNHC CPS UNJ UNJC Emergency Lighting (for use in hazardous [classified] locations) Emergency lighting for use in power outage situations. Also, exit signs and strobe warning lights. N2LPS Light-Pak™ Series CPMVFB EXL Exit Sign DMVFB ™ ELPS Light-Pak Series N2MVFB Ex-Lite EVLPFB CCH UX Series Section 10L Specialty Lighting Luminaires for use in applications where conventional lighting is not acceptable due to size and/or location, such as tank, instrument, and gauge applications. For hazardous For non-hazardous locations locations EV – tank lights V Observation EVTL ELG – gauge light Copyright© 2013 Eaton’s Crouse-Hinds Business 862-863.qxp 12/16/2013 6:38 PM Page 863 L Industrial Lighting Products Quick Reference Chart Application Environment Light Source LED Incandescent H.I.D. / Induction • Pulse Start Metal Halide • Metal Halide • High Pressure Sodium Fluorescent • Linear • Long Twin Tube • Compact Emergency & Warning • Exit Signs • Emergency Lighting WallPacks & Floodlights • Pulse Start Metal Halide • Metal Halide • High Pressure Sodium • Incandescent Section 2L Champ® Pro PVM Series, Champ® Pro PFM Series, Vaporgard™ Pro P2L Series, Industrial High Bay Section 1L Vaporgard™, V Series, NDA Section 11L V160 Tank light Section 3L LMV, DMV, VMV, N2MV Champ®, Champ Induction Section 5L VF Series, NFL, FVN, FVS, DMVF, N2MVF Section 2L Ex-Lite, CCH UX, N2LPS LightPak™ Section 9L DMVFB, N2MVFB Section 6L F2MV, FMV, FMV1000 Marine/Wet Locations or 4X Section 2L Champ® VMV LED, Vaporgard™ LED, EV LED Section 1L NDA Section 3L LMV, DMV, VMV, N2MV Champ® Section 4L EVLP, EVM Hazard•Gard® Section 5L NFL, FVS, DMVF, N2MVF, CPMVF, EVFDR, EVFT Illuminator™ Section 2L Ex-Lite, CCH UX Section 9L DMVFB Section 6L CPMV, F2MV, FMV, FMV1000 Corrosive Section 2L Champ® VMV LED, Vaporgard™ LED, EV LED Section 1L Vaporgard™, NDA Section 3L LMV, DMV, VMV, N2MV Champ®, Champ Induction Section 5L NFL, N2MVF, FVS, VF Series, DMVF, CPMVF Section 2L Ex-Lite, CCH UX, N2LPS LightPak™ Section 9L DMVF-EXD Exit, N2MVFB, DMVFB Section 6L CPMV, F2MV, FMV, FMV1000 Class I, Div. 1 or Zone 1 Section 2L EV LED, EVLL, LPL Section 1L EV Section 10L EVTL, EVA160, EVO, ELG Section 4L EVLP, EVLS, EVM Hazard•Gard® Section 5L EVF, EVFDR, EVFT Illuminator™, EVLPF, eLLK Section 9L EXL Exit, EVLPF-EXD Exit, ELPS Light-Pak™, EVLPFB Section 6L FZD, EVM-S812, RCDE Class I, Div. 2 and Zone 2 Section 2L Champ® VMV LED, Vaporgard™ LED, Champ® FMV LED, LL48 Section 1L Vaporgard™, NDA Section 3L LMV, DMV, VMV, N2MV Champ®, Champ Induction Section 5L VF Series, NFL, nLLK, eLLK, FVN, FVS, CPMVF, DMVF, N2MVF Section 2L Ex-Lite Section 9L DMVF-EXD Exit, N2LPS LightPak™, DMVFB, N2MVFB Section 6L CPMV, F2MV, FMV, FMV1000, FZD Restricted Breathing • Class I, Div 2 and Zone 2 • Certified IEC Zone 2 Section 2L Champ® VMV LED, Champ® NFMV LED, Vaporgard™ NV2L LED Section 3L LMV, DMV, VMV, N2MV Champ®, Champ Induction Section 5L CPMVF, DMVF, N2MVF Section 9L DMVFB, N2MVFB Section 6L CPMV, F2MV, FMV Class II Class III Simultaneous Presence Section 2L Champ® VMV LED, EV LED, Vaporgard™ LED, Champ® FMV LED, EVLL Section 3L LMV, DMV, VMV, N2MV Champ®, Champ Induction Section 4L EVLP, EVM Hazard•Gard® Section 5L FVN, nLLK, eLLK, FVS, DMVF, N2MVF, EVF, EVFDR, EVFT, EVLP Section 2L Ex-Lite Section 9L EXL, N2LPS LightPak™, DMVFB, N2MVFB, ELPS Light-Pak™ Section 6L CPMV Section 8L EVP Section 5L EVF, EVFT Section 8L EVP Section 8L EVH Section 1L EV Section 10L EVTL, EVO Paint Spray Portables Section 8L VS, EVH, RCDER www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 L General Industrial Copyright© 2013 Eaton’s Crouse-Hinds Business 863 864-865.qxp L 12/16/2013 6:38 PM Page 864 Industrial Lighting Products Lighting Layout Services Lighting Application and Design In the past, engineers had to calculate lighting layouts and design using complex mathematical formulas - also known as the "Lumen Method" and "Point-By-Point" Method. Today, there are software programs that can easily run these calculations very quickly. Lighting layouts, analysis, and design from Eaton's Crouse-Hinds deliver a real competitive advantage. For over 100 years, Eaton's CrouseHinds has been providing hazardous area lighting solutions. Our light fittings are manufactured to the highest standards and will provide years of reliable service and performance under the harshest conditions. Lighting Software Eaton's Crouse-Hinds' Luxicon Pro™ software program makes it very easy to perform lighting calculations and create professional quality designs. Our latest version, LUXICON® 2.5.25, is distributed free of charge and includes a tutorial to introduce users to its operation and several "Wizards" that will assist in a step-by-step process to create your own lighting design. You can also add in objects that will account for light inference caused by equipment, walls, and other obstructions in the work area. It will also provide detail point-by-point calculations and statistical analysis. Pro TM Point-by-point light calculation in plan view Lighting Layout Services L Need help with a more complex lighting design or analysis? Then take advantage of our free lighting design service. Our lighting designers can provide you with lighting layouts for more complex projects that will interface with the latest version of AutoCAD drawings and will provide a more detailed lighting analysis. Calculations shown with light fixture placement 864 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Illuminance rendering Copyright© 2013 Eaton’s Crouse-Hinds Business 864-865.qxp 12/16/2013 6:38 PM Page 865 Industrial Lighting Products L Mercury Vapor Luminaires Discontinuation Notice Eaton's Crouse-Hinds no longer produces luminaires containing Mercury Vapor ballasts in any of our U.S. facilities. Alternative Solutions In 2005, the U.S. government signed the Energy Policy Act of 2005. The law, commonly referred to as EPACT 2005, contained many new changes in requirements for energy production, energy transportation, and energy efficiency. One of those changes calls for the elimination of manufacturing and importation of Mercury Vapor (MV) ballasts in the United States after January 1, 2008. LED Mercury Vapor ballasts have lower lumens per watt than alternative HID light sources and are far less energy-efficient than LED, High Pressure Sodium (HPS), or Metal Halide (MH) ballasts. As demand for energy-efficient lighting grows, we expect a subsequent drop in the usage of Mercury Vapor ballasts globally. This could lead to longer lead times and potentially worldwide discontinuation at some point in the future. Eaton's Crouse-Hinds suggests the use of alternative technologies, such as LED, that provide better efficacy, color rendering, length of life, and environmentally friendlier solutions. Alternative HID light sources, such as High Pressure Sodium or Metal Halide, are also viable product solutions. While we recommend switching to an alternative light source, there are many countries in the world that still allow the use of Mercury Vapor ballasts. As long as the ballasts and lamps remain available, we can still offer Mercury Vapor luminaires out of our manufacturing facilities located outside of the United States. The Mercury Vapor luminaires will be manufactured in our Eaton's Crouse-Hinds Mexico facility and shipped directly from there. For available Mercury Vapor products, please contact customer service. US: 1-866-764-5454 Lumens Lumens per Watt 60,000 60,000 60,000 60,000 60,000 3,515 5,288 7,404 9,515 10,935 77.39 78.93 78.77 83.47 92.67 60,000 60,000 60,000 60,000 60,000 4,386 6,720 8,478 10,420 12,940 68.53 75.51 70.07 69.93 72.29 60,000 1,633 74.23 60,000 60,000 1,670 2,248 55.67 62.44 60,000 60,000 60,000 60,000 60,000 5,625 6,750 9,000 10,500 13,500 70.30 67.50 69.23 69.54 77.14 High Pressure Sodium 100W 24,000 250W 24,000 400W 24,000 1000W 24,000 9,500 28,500 50,000 140,000 95.00 114.00 125.00 140.00 Metal Halide 175W 250W 400W 1000W 10,000 20,000 20,000 12,000 13,500 20,500 36,000 110,000 77.00 82.00 90.00 110.00 Pulse Start Metal Halide 175W 15,000 250W 15,000 400W 20,000 16,000 23,800 44,000 91.00 95.00 100.00 Induction 55W 85W 165W 100,000 100,000 100,000 3,500 6,000 12,000 63.00 70.00 72.00 Mercury Vapor 100W 175W 250W 400W 1000W 24,000 24,000 24,000 24,000 24,000 4,100 7,900 12,100 21,000 57,500 34.00 45.00 48.00 52.00 57.00 VMV / PVM 41W 67W 94W 114W 118W FMV / PFM 64W 89W 121W 149W 179W V2L / P2L 22W EV LED 30W 36W EVLL 80W 100W 130W 151W 175W CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business L www.crouse-hinds.com Hours Luminaire Type 865 866-867.qxp 12/16/2013 L 6:38 PM Page 866 Lamps Used With Eaton's Crouse-Hinds Luminaires Lamp Watts H.I.D. Medium Base Series – LMV, EVLP_ 1 ANSI Ballast Manufacturer Lamp Catalog Number GE Osram/Sylvania Phillips Venture High Pressure Sodium 50 70 100 S68 S62 S54 LU50/MED LU70/MED LU100/MED LU50/MED LU70/MED LU100/MED C50S68/M C70S62/M C100S54/M 150 S55 LU150/MED LU150/MED C150S55/M 70 100 M98 M90 MXR70/U/MED MXR100/U/MED MP70/U/MED MP100/U/MED MHC70/U/M/3K MHC100/U/M/3K 175* M57 MVR175/U/MED M175/U/MED MH175/U/M MXR150/U/MED MXR175/VBU/MED/PA MP150/U/MED Metal Halide MH70W/U MH100W/U Pulse Start Metal Halide 150 175 M102 M137 L *For export only. 866 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business MH150W/U/PS MS175W/BU/MED/PS 866-867.qxp 12/16/2013 6:38 PM Page 867 Lamps Used With Eaton's Crouse-Hinds Luminaires Lamp Watts L H.I.D. Medium Base Series – LMV, EVLP_ 1 ANSI Ballast Manufacturer Manufacturer Lumens/Life (hrs) Bulb GE O/S PH Venture GE O/S PH Venture High Pressure Sodium 50 70 100 S68 S62 S54 4000/24K 6400/24K 9500/24K 4000/24K 6300/24K 9500/24K 4000/24K 6300/24K 9500/24K B17 B17 B17 E17 E17 E17 ED17 ED17 ED17 150 S55 16000/24K 15800/24K 16000/24K B17 E17 ED17 70 100 M98 M90 5500/12K 9000/15K 5200/15K 8500/15K 6200/10K 9300/12.5K BD17 BD17 E17 E17 ED17 ED17 175* M57 13600/10K 14400/10K 13500/10K BD17 ED17 ED17 12500/15K 17700/15K 13300/15K BD17 BD17 E17 E17 Metal Halide 5600/15K 9000/15K ED17 ED17 Pulse Start Metal Halide 150 175 M102 M137 14000/15K 17500/15K ED17 ED17 *For export only. L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 867 868-869.qxp 12/16/2013 L 6:39 PM Page 868 H.I.D. Mogul Base Series - DMV, VMV, CPMV, FMV, F2MV, EVLP_0, FZD Lamps Used With Eaton's Crouse-Hinds Luminaires Lamp Watts ANSI Ballast Manufacturer GE Osram/Sylvania Phillips Venture High Pressure Sodium 50 70 100 150 S68 S62 S54 S55 LU50 LU70 LU100 LU150/55 LU50 LU70 LU100 LU150/55 C50S68 C70S62 C100S54 C150S55 150 (100V) 200 250 310 400 1000 S56 S66 S50 S67 S51 S52 LU150/100 LU200 LU250 LU310 LU400 LU1000 LU150/100 LU200 LU250 LU310 LU400 LU1000 C150S56 C200S66 C250S50 C310S67 C400S51 C1000S52 M175/U M250U M400/U M400/U/BT-28 M1000/U M1500/BD MHC100/U/ED28/HR/4K MH175/U MH250/U MH400/U MH400/U/ED28 MH1000/U MH1500/BD (Base up +/– 15%) (Base up +/– 15%) Metal Halide 70 100 175* 250* 400* 400* 1000 1500 M98 M90 M57 M58 M59 M59 M47 M48 MVR175/U MVR250/U MVR400/U MVR400/U/ED28 MVR1000/U MVR1500/HBD Pulse Start Metal Halide L 150 175 200 250 M102 M137 M136 M138 M138 M132 M131 M131 M135 M135 M135 M135 M141 320 350 400 1000 MXR175/VBU/PA CDM150/U/PS/4K ALTO MS175/BU/PS MXR250/VBU/PA MS250/BU/PS MXR320/VBU/PA MS320/PS/BU-ONLY MS320W/BU/PS MXR400/VBU/PA MS400/PS/BU-ONLY MS400/BU/PS HQI-DE 70/WDX CDM70/TD/830 HID Double Contact Metal Halide for EVP Series 70W CMH70/TD/830/R7S *For export only. 868 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business MH70W/U/ED28 MH100W/U/ED28 MH150W/U/ED28/PS MS175W/BU/PS MH200W/U/PS MH250W/HBU/PS MH250W/HBD/PS MH320W/U/ED28/PS MH350W/U/PS MH350W/U/ED28/PS MH400W/HBU/PS MH400W/HBD/PS MH400W/HBU/ED28/PS MH400W/HBD/ED28/PS 868-869.qxp 12/16/2013 6:39 PM Page 869 Lamps Used With Eaton's Crouse-Hinds Luminaires Lamp Watts ANSI Ballast L H.I.D. Mogul Base Series - DMV, VMV, CPMV, FMV, F2MV, EVM, EVLP_0, FZD Manufacturer Manufacturer Lumens/Life (hrs) Bulb GE O/S PH Venture 4000/24K 6400/24K 9500/24K 16000/24K 15000/24K 22000/24K 28000/24K 37000/24K 51000/24K 140000/24K 4000/24K 6300/24K 9500/24K 16000/24K 15700/24K 22000/24K 29000/24K 37000/24K 50000/24K 130000/24K 4000/24K 6300/24K 9500/24K 16000/24K 16000/24K 22000/24K 28500/24K 37000/24K 50000/24K 140000/24K GE O/S PH ED23 1/2 ED23 1/2 ED23 1/2 ED23 1/2 ED28 ED18 ED18 ED18 ED18 E25 ET23 1/2 ET23 1/2 ET23 1/2 ET23 1/2 BT28 ET18 ET18 ET18 ET18 E25 ED23 1/2 ED23 1/2 ED23 1/2 ED23 1/2 ED28 ED18 ED18 ED18 ED18 E25 Venture High Pressure Sodium 50 70 100 150 150 (100V) 200 250 310 400 1000 S68 S62 S54 S55 S56 S66 S50 S67 S51 S52 Metal Halide 70 100 175 250 400 400 1000 1500 M98 M90 M57 M58 M59 M59 M47 M48 5600/15K 9000/15K 13600/10K 20800/10K 36000/20K 36000/20K 105000/12K 155000/3K 14400/10K 22000/10K 36000/20K 36000/20K 110000/15K 155000/3K 13500/10K 20500/20K 36000/20K 36000/20K 110000/12K 165000/3K ED28 ED28 ED28 ED28 ED37 ED28 BT56 BT56 BT28 BT28 BT37 BT28 BT56 BT56 ED28 ED28 ED37 ED28 BT56 BT56 Pulse Start Metal Halide 150 175 200 250 320 350 1000 17200/15K 13000/24K 16000/15K 23000/15K 23800/15K 31000/15K 32000/20K 44000/20K 41000/20K 44000/20K 14000/15K 17500/15K 21000/15K 25000/15K 25000/15K 33000/20K 37000/20K 37000/20K 44000/20K 44000/20K ED23 1/2 ED23 1/2 ED28 ED28 ED28 ED28 BT28 ED28 ED37 BT37 ED37 44000/20K www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business ED28 ED28 ED28 ED28 ED28 ED28 ED37 ED28 ED37 ED37 ED28 ED28 L 400 M102 M137 M136 M138 M138 M132 M131 M131 M135 M135 M135 M135 M141 869 870-871.qxp 12/16/2013 6:39 PM Page 870 Lamps Used With Eaton's Crouse-Hinds Luminaires L Lamp Watts Fluorescent Lamps Luminaire Series Base Manufacturer GE Osram/Sylvania Phillips Compact 5W-T4 G23 VF F5BX/SPX41/840 CF5DS/841 PL-S5W/27 7W-T4 G23 VF F7BX/SPX35/835 CF7DS/835 PL-S7W/35 9W-T4 G23 VF F9BX/SPX35/835 CF9DS/835 PL-S9W/35 13W-T4 GX23-2 DMVF (Discontinued) F13DBX23T4/SPX35 CF13DD/835 PL-C13W/35/USA 26W-T4 GX24q-3 DMVF, N2MVF, CPMVF, EVLPF F26TBX/SPX35/A/4P CF26DT/E/IN/835 PL-T26W/35/4P/ALTO 32W-T4 GX24q-3 DMVF, N2MVF, CPMVF, EVLPF F32TBX/SPX35/A/4P CF32DT/E/IN/835 PL-T32W/35/4P/ALTO 42W-T4 GX24q-4 DMVF, N2MVF, CPMVF, EVLPF F42QBX/SPX35/A/4P CF42DT/E/IN/835 PL-T42W/35/4P/ALTO Long Twin Tube 39 2G11 EVFT F39/36/BX/SPX35 FT36DL/835 PL-L36W/35 40 2G11 NFL, FVS F40/30BX/SPX35 FT40DL/835/RS PL-L40W/35/RS 32W-T8 Medium Bipin NFL, FVN, EVF, EVFDR F32T8/SP35 F032/735 F32T8/TL735/ALTO 40 (34) W-T12 Medium Bipin NFL, FVN, EVF, EVFDR F40CW/RS/WM F40CW/SS F40CW/RS/EW/ALTO 54W-T5HO Miniature Bipin FVN F54T5/841/WH/ECO HO54W/835 F54T5/830/HO/ALTO 60W (800ma)-T12 High Output Recessed Double Contact FVN, EVF, EVFDR F48T12/CW/HO F48T12/CW/HO F48T12/CW/HO 110W (1500ma)-T12 Very High Output Recessed Double Contact EVF, EVFDR F48T12/CW/1500 F48T12/CW/VHO F48T12/CW/VHO L Linear 870 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 870-871.qxp 12/16/2013 6:39 PM Page 871 Lamp Watts L Incandescent & Quartz (Halogen) Lamps Lamps Used With Eaton's Crouse-Hinds Luminaires Base Luminaire Series Manufacturer Lumens/Life (Hrs) GE Osram/Sylvania Phillips Compact 5W-T4 G23 VF 250/10K 230/10K 250/10K 7W-T4 G23 VF 400/10K 400/10K 400/10K 9W-T4 G23 VF 600/10K 580/10K 600/10K 13W-T4 GX23-2 DMVF (Discontinued) 810/10K 780/10K 860/10K 26W-T4 GX24q-3 DMVF, N2MVF, CPMVF, EVLPF 1800/10K 1800/10K 1800/10K 32W-T4 GX24q-3 DMVF, N2MVF, CPMVF, EVLPF 2200/10K 2400/10K 2400/10K 42W-T4 GX24q-4 DMVF, N2MVF, CPMVF, EVLPF 3200/10K 3200/10K 3200/10K Long Twin Tube 39 2G11 EVFT 2850/12K 2900/12K 2900/12K 40 2G11 NFL, FVS 3150/20K 3150/20K 3150/20K 32W-T8 Medium Bipin NFL, FVN, EVF, EVFDR 2850/20K 2800/20K 2850/20K 40 (34) W-T12 Medium Bipin NFL, FVN, EVF, EVFDR 2650/20K 2700/20K 2650/20K 54W-T5HO Miniature Bipin FVN 4600/30K 4450/24K 4750/35K 60W (800ma)-T12 High Output Recessed Double Contact FVN, EVF, EVFDR 4050/12K 4050/12K 4050/12K 110W (1500ma)-T12 Very High Output Recessed Double Contact EVF, EVFDR 6200/10K 6600/10K 7050/12K Linear US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 871 L www.crouse-hinds.com 872-873.qxp 12/16/2013 6:40 PM Page 872 Lamps Used With Eaton's Crouse-Hinds Luminaires L Max Watts And Bulb Type Incandescent & Quartz (Halogen) Lamps Luminaire Series Manufacturer GE Phillips EXLD 25T10 25T10 25T10 50W PAR20 EVTL 50PAR20/H/SP10 50PAR20/H/FL25 50PAR20/CAP/NSP 50PAR20/CAP/NFL 50PAR20/HAL/NSP9 50PAR20/HAL/NFL30 52W A19 58W A19 ELG ELG 60A52WMP/98 60A52/SS/XL 58A19/62 60A-52A/99/EW 25W T10 60W T10 EXL 60T10 60T10 60T10 65W BR30 EVO2376 75R30/SP/65WM 65BR30/SP 65BR30/SP20 75W ER30 EVO2376 75ER30 75ER30 75ER30 100W A19 EV 40 Series / EVI 100A (IF) 100A (IF) 100A (IF) 100W A21 V160, EV160, EVH, EV 15 Series / EVI 100A21 (IF) 100A21 (IF) 100A21 (IF) 100W A23 VS 100A23 120V 100A23 100A23 100W D.C. Bay Suffix QTZ Q100CL/DC 100Q/CL/DC 100Q/CL/DC 150W A21 Vaporgard 150W EV 10 Series / EVI EV 20 Series 150A (IF) 150A (IF) 150A (IF) 150W A23 V Series 150A23 (IF) 150A23/CL 150W PAR38 RCDE6 150PAR/FL 150PAR38/2FL 200W A23 Vaporgard 200W EV 10 Series / EVI 200A23 (IF) 200A (IF) 200W A25 Vaporgard 200W EV 15 Series / EVI 200W PS25 EV 15 Series / EVI 200W PS30 EV 20 Series / EVI EV 30 Series / EVI 200 130V 300W PS25 Vaporgard 300W NDA EV 15 Series / EVI 300M 300W PS30 Vaporgard 300W EV 20 Series / EVI EV 15 Series / EVI 300M/99 (130v) 300M/CL 300M/PS30 300W R40 RCDE6 300R/FL 300R40/FL 300BR/FL 300W PS35 EV 30 Series / EVI 300 300/CL 500W PS40 EV 30 Series / EVI 500PS40 500W PAR64 RCDE10 500PAR64/MFL L 872 Osram/Sylvania www.crouse-hinds.com US: 1-866-764-5454 200A25/35 200PS25/99XL CAN: 1-800-265-0502 200PS/CL 130V 200 130V 300M 300 500PS40 500PAR64/MFL Copyright© 2013 Eaton’s Crouse-Hinds Business 500PAR64/MFL 872-873.qxp 12/16/2013 6:40 PM Page 873 Incandescent & Quartz (Halogen) Lamps Lamps Used With Eaton's Crouse-Hinds Luminaires Max Watts And Bulb Type Manufacturer Manufacturer Lumens GE O/S L Life-Hours PH GE O/S PH 25W T10 248 232 260 1000 1000 1000 50W PAR20 570 570 530 530 550 550 2500 2500 2500 2500 2000 2000 52W A19 670 650 564 2500 2500 4250 58W A19 630 630 630 3000 3000 3000 60W T10 740 630 745 1000 1000 1000 65W BR30 775 640 2000 2000 2000 75W ER30 850 750 2000 2000 2000 100W A19 1710 1750 1650 750 750 750 100W A21 1710 1690 1680 750 750 750 100W A23 1600 1730 750 750 750 100W D.C. Bay 1600 1600 1600 2000 2000 2000 150W A21 2850 2780 2850 750 750 750 2810 2475 750 1275 1660 1660 2000 2000 3930 3800 150W A23 150W PAR38 1660 200W A23 2000 750 750 200W A25 2720 2720 2720 3500 3500 3500 200W PS25 3000 3000 3000 2500 2500 2500 200W PS30 2725 2665 2825 1950 1875 2120 300W PS25 6200 6280 750 750 750 300W PS30 3935 5870 6100 6800 7500 7500 3700 3030 np 2000 2000 2000 5820 5700 5700 1000 1000 1000 500W PS40 9900 10100 10100 1000 1000 1000 500W PAR64 6500 2000 2000 2000 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business L 300W R40 300W PS35 873 874-875.qxp 12/16/2013 Page 874 Ballasts Used With Eaton's Crouse-Hinds Luminaires L Watts 6:40 PM ANSI Code Volts Starting Current Operating Current Input Watts Kit Cat. # t220/240–50 Hz R-HPF HX-HPF HX-HPF 1.0 0.7/0.3 0.3/0.3 0.6 0.6/0.3 0.6/0.6 62 66 66 CHRBS050/120 CHRBS050/DT CHRBS050/220 50 S62 120 120/208/240/277 120/277/347 220 480 220/240–50 Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 0.9 0.8/0.5/0.4/0.4 .8/.4/.3 0.4 0.2 .5/.4 0.8 0.8/0.5/0.4/0.4 0.8/0.4/0.3 0.4 0.2 .5/.4 86 91 93 91 93 94 CHRBS070/120 CHRBS070/MT CHRBS070/MT CHRBS070/220 CHRBS070/480 CHRBS070/220 50 S54 120 120/208/240/277 120/277/347 220 480 220/240–50 Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 1.5 1.3/0.8/0.7/0.6 1.3/0.6/0.5 0.7 0.4 0.5/0.5 1.1 1.2/0.7/0.6/0.5 1.2/0.5/0.4 0.6 0.3 0.7/0.6 115 130 130 130 130 130 CHRBS100/120 CHRBS100/MT CHRBS100/TT CHRBS100/220 CHRBS100/480 CHRBS100/220 50 150 (55v) S55 120 120/208/240/277 120/277/347 220 480 220/240–50 Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 2.3 2.0/1.2/1.0/0.9 2.0/0.9/0.5 1.1 0.5 0.9/0.8 1.5 1.7/1.0/0.8/0.7 1.7/0.7/0.6 0.9 0.4 0.9/0.8 170 188 188 188 188 188 CHRBS150/120 CHRBS150/MT CHRBS150/TT CHRBS150/220 CHRBS150/480 CHRBS150/220 50 150 (100v) S56 120/208/240/277 480 220/240–50 Hz CWA CWA R-HPF 1.2/0.7/0.6/.05 0.3 0.9/1.0 1.8/1.0/0.9/0.8 0.4 0.9/0.8 188 188 175 CHRBS150/MT CE CHRBS150/480 CE CHRBS150/220 50 CE 200 S66 120/208/240/277 480 CWA CWA 1.4/0.8/0.7/0.6 0.4 2.4/1.4/1.2/1.0 0.6 250 250 CHRBS200/MT CHRBS/200/480 S50 120 120/208/240/277 120/277/347 220 480 230–50 Hz CWA CWA CWA CWA CWA CWA 1.7 1.7/1.0/0.8/0.7 1.7/0.7/0.6 0.9 0.4 1.0 2.5 2.5/1.5/1.3/1.1 2.7/1.2/0.9 1.5 0.7 1.4 295 295 295 295 310 300 CHRBS250/120 CHRBS250/MT CHRBS250/TT CHRBS250/220 CHRBS250/480 CHRBS250/220 50 S51 120 120/208/240/277 120/277/347 220 480 230–50 Hz CWA CWA CWA CWA CWA CWA 3.3 3.3/1.8/1.5/1.4 3.3/1.4/1.0 1.6 0.8 1.9 3.8 3.8/2.2/1.9/1.7 3.8/1.7/1.3 2.1 1.0 2.0 457 464 464 457 464 465 CHRBS400/120 CHRBS400/MT CHRBS400/TT CHRBS400/220 CHRBS400/480 CHRBS400/220 50 S52 120/208/240/277 120/277/347 220 480 220/240–50 Hz CWA CWA CWA CWA CWA 6.4/3.8/3.2/2.8 6.4/2.8/2.2 3.6 1.6 6.0/5.6 9.5/5.5/4.8/4.2 9.5/4.2/3.3 5.0 2.3 5.2/4.8 1100 1100 1100 1100 1100 CHRBS1000/MT CHRBS1000/TT CHRBS1000/220 CHRBS1000/480 CHRBS1000/220 50 50 70 L 100 S68 120 120 / 277 Type R/HX/CWA High Pressure Sodium Data 250 400 1000 874 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 874-875.qxp 12/16/2013 6:40 PM Page 875 Pulse Start Metal Halide Data Ballasts Used With Eaton's Crouse-Hinds Luminaires Watts ANSI Code 150 L Volts Type R/HX/CWA Starting Current Operating Current Input Watts Kit Cat. # M102 120/208/240/277 120/277/347/480 HX-HPF HX-HPF 1.8/1.3/0.9/0.8 1.8/0.8/0.7 1.6/1.0/0.8/0.7 1.6/0.7/0.6 185 185 CHRBM150/MTS828 CHRBM150/TTS828 175* M137 120/208/240/277 120/208/240/277 120/277/347/480 Super CWA Super CWA Super CWA 1.0/0.6/0.5/0.4 1.0/0.6/0.5/0.4 0.8/0.4/0.3 1.8/1.1/0.9/0.8 1.8/1.1/0.9/0.8 1.9/0.8/0.7 208 208 208 CHRBM175/MTS828 CHRBMVMV175/MTS828** CHRBM175/TTS828 200* M136 120/208/240/277 120/277/347 480 Super CWA Super CWA Super CWA 0.8/0.4/0.4/0.3 0.7/0.3/0.3 0.2 2.0/1.2/1.0/0.9 2.1/0.9/0.7 0.5 232 232 232 CHRBM200/MTS828 CHRBM200/TTS828 CHRBM200/480S828 250* M138 120/208/240/277 120/277/347 Super CWA Super CWA 2.3/1.3/1.2/1.0 2.0/0.9/0.8 2.5/1.5/1.3/1.1 2.5/1.1/0.9 288 290 CHRBM250/MTS828 CHRBM250/TTS828 M132 120/208/240/277 120/277/347 220 Super CWA Super CWA Super CWA 1.8/1.1/0.9/0.8 2.2/1.0/0.7 1.4 3.3/1.9/1.7/1.4 3.3/1.4/1.1 1.7 368 368 365 CHRBM250/MTS828 CHRBM250/TTS828 CHRBM250/220S828 480 230 / 50 Super CWA Super CWA 0.5 1.1 0.8 1.6 368 365 CHRBM250/480S828 CHRBM250/220 50S828 320* 400* 1000 M135 120/208/240/277 120/277/347 480 230 / 50 Super Super Super Super CWA CWA CWA CWA 2.9/1.7/1.5/1.3 3.2/1.4/1.1 0.8 2.0 3.8/2.2/1.9/1.7 3.8/1.7/1.4 1.0 2.1 452 450 452 454 CHRBM400/MT S828 CHRBM400/TTS828 CHRBM400/480S828 CHRBM400/220 50S828 M141 120/208/240/277 347 480 220/240–50 Hz Super CWA Super CWA Super CWA CWA 7.8/4.0/3.7/3.2 2.3 1.7 4.5/4.1 9.0/5.2/4.5/3.9 3.2 2.4 5.0/4.5 1080 1075 1075 1090 CHRBM1000/MTS828 CHRBM1000/347S828 CHRBM1000/480S828 CHRBM1000/220 50S828 L *EISA compliant. **For VMV replacement only. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 875 876-877.qxp 12/16/2013 6:40 PM Page 876 Metal Halide Data Ballasts Used With Eaton's Crouse-Hinds Luminaires L Watts ANSI Code Volts Type R/HX/CWA Starting Current Operating Current Input Watts Kit Cat. # 70 M98 120/208/240/277 120/277/347 220 220/240–50 Hz HX-HPF HX-HPE HX-HPF HX-HPF 0.6/0.3/0.3/0.3 0.6/0.2/0.2 0.4 0.7/0.6 0.8/0.5/0.4/0.4 0.8/0.4/0.3 0.5 0.5/0.4 88 88 94 95 CHRBM070/MT CHRBM070/TT CHRBM070/220 CHRBM070/220 50 M90 120/208/240/277 120/277/347 220 480 220/240–50 Hz HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 1.2/0.8/0.7/0.6 1.2/0.5/0.4 0.9 0.3 0.7/0.7 1.2/0.7/0.6/0.5 1.2/0.5/0.4 0.6 0.3 0.7/0.6 129 129 129 132 129 CHRBM100/MT CHRBM100/TT CHRBM100/220 CHRBM100/480 CHRBM100/220 50 M57 120 120/208/240/277 120/277/347 220 480 230 / 50 CWA CWA CWA CWA CWA CWA 1.3 1.3/0.8/0.7/0.6 1.3/0.6/0.5 0.6 0.4 0.8 1.8 1.8/1.1/0.9/0.8 1.8/0.8/0.7 1.0 0.5 1.1 210 210 210 210 210 210 CHRBM175/120 CHRBM175/MT CHRBM175/TT CHRBM175/220 CHRBM175/480 CHRBM175/220 50 M58 120 120/208/240/277 120/277/347 220 480 230 / 50 CWA CWA CWA CWA CWA CWA 1.0 1.0/0.6/0.5/0.5 2.2/1.0/0.8 1.4 0.6 1.0 2.6 2.6/1.5/1.3/1.1 2.5/1.1/0.9 1.5 0.6 1.3 294 294 295 295 295 290 CHRBM250/120 CHRBM250/MT CHRBM250/TT CHRBM250/220 CHRBM250/480 CHRBM250/220 50 M59 120 120/208/240/277 120/277/347 220 480 230 / 50 CWA CWA CWA CWA CWA CWA 3.0 3.5/2.0/1.8/1.5 3.5/1.5/1.2 1.9 0.9 1.4 4.0 4.0/2.2/2.0/1.8 4.0/1.8/1.4 2.2 1.0 2.1 456 458 460 458 462 462 CHRBM400/120 CHRBM400/MT CHRBM400/TT CHRBM400/220 CHRBM400/480 CHRBM400/220 50 M47 120/208/240/277 120/277/347 220 480 220/240–50 Hz CWA CWA CWA CWA CWA 7.8/4.0/3.7/3.2 7.8/3.2/2.5 3.9 1.9 4.5/4.1 9.0/5.2/4.5/3.9 9.0/3.9/3.2 4.9 2.3 5.0/4.5 1080 1080 1080 1080 1090 CHRBM1000/MT CHRBM1000/TT CHRBM1000/220 CHRBM1000/480 CHRBM1000/220 50 M48 120/208/240/277 120/277/347 220 480 220/240–50 Hz CWA CWA CWA CWA CWA 13.4/7.7/6.7/5.7 13.4/5.7/4.6 7.3 3.3 6.9/6.3 13.5/7.8/6.8/5.9 13.5/5.9/4.8 7.4 3.4 7.5/6.9 1605 1615 1605 1625 1605 CHRBM1500/MT CHRBM1500/TT CHRBM1500/220 CHRBM1500/480 CHRBM1500/220 50 100 175* 250* 400* L 1000 1500 *Must purchase directly from Advance. 876 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 876-877.qxp 12/16/2013 6:40 PM Page 877 Fluorescent Data Ballasts Used With Eaton's Crouse-Hinds Luminaires Luminaire Series Lamp Type & Watts L Lamp Base Lamp No. Qty. Ballast Voltage Starting Operating Amp Input Watts Kit Cat. # G23 2 120 0.4 22 CHRBF2C018/120 Compact VF 9W T4 DMVF, N2MVF, EVLPF 26W 26W 26W 26W 26W 26W 26W T4 T4 T4 T4 T4 T4 T4 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 2 2 2 2 2 2 2 120 220 / 240 277 347 DC 12V DC 24V DC 125V 0.5 0.3 0.2 0.2 3.6 1.8 0.67 55 55 55 44 43 43 55 CHRBF4C084/UNV CHRBF4C084/UNV CHRBF4C084/UNV CHRBF4C084/347 CHRBF4C084/12VDC CHRBF4C084/24VDC CHRBF4C084/UNV DMVF, N2MVF, EVLPF 32W 32W 32W 32W 32W 32W 32W T4 T4 T4 T4 T4 T4 T4 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 2 2 2 2 2 2 2 120 220 / 240 277 347 DC 12V DC 24V DC 125V 0.6 0.3 0.3 0.2 4.4 2.2 0.67 68 68 68 62 60 60 68 CHRBF4C084/UNV CHRBF4C084/UNV CHRBF4C084/UNV CHRBF4C084/347 CHRBF4C084/12VDC CHRBF4C084/24VDC CHRBF4C084/UNV CPMVF, DMVF 42W 42W 42W 42W T4 T4 T4 T4 GX24q-4 GX24q-4 GX24q-4 GX24q-4 2 2 2 2 120 277 347 DC 125V 0.8 0.3 0.3 0.67 93 68 80 93 CHRBF4C084/120 CHRBF4C084/277 CHRBF4C084/347 CHRBF4C084/UNV Long Twin Tube 40W 40W 40W 40W T5 T5 T5 T5 2G11 2G11 2G11 2G11 1 1 1 1 120 277 347 120 - 277 0.4 0.2 0.1 0.2 42 42 44 41 CHRBFT80/UNV CHRBFT80/UNV CHRBFT80/347 CHRBFT80/UNV FVS 40W 40W 40W 40W T5 T5 T5 T5 2G11 2G11 2G11 2G11 2 2 2 2 120 277 347 120 - 277 0.6 0.3 0.2 0.3 76 73 70 74 CHRBFT080/UNV CHRBFT080/UNV CHRBFT080/347 CHRBFT080/UNV 36/39W 36/39W 36/39W 2G11 2G11 2G11 2 2 2 120 277 220 / 240 0.6 0.3 0.3 74 74 71 CHRBFT078/120 CHRBFT078/277 CHRBFT078/220 EVFT L NFL Note: For 3 lamp luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values. For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 877 878-879.qxp 12/16/2013 L Luminaire Series 6:41 PM Page 878 Fluorescent Data Ballasts Used With Eaton's Crouse-Hinds Luminaires Lamp Type & Watts Lamp Base Lamp No. Qty. Ballast Voltage Starting Operating Amp Input Watts Kit Cat. # LINEAR 32W 32W 32W 32W 32W 32W 32W 32W Med Med Med Med Med Med Med Med Bipin Bipin Bipin Bipin Bipin Bipin Bipin Bipin 1 1 1 1 2 2 2 2 120 277 347 220 / 240 120 277 347 220 0.3 0.2 0.1 0.3 0.5 0.2 0.1 0.4 35 35 32 38 58 58 50 58 CHRBFL064/UNV CHRBFL064/UNV CHRBFL64/347 CHRBFL064/UNV CHRBFL064/UNV CHRBFL064/UNV CHRBFL64/347 CHRBFL064/UNV NFL, FVN, EVF & EVFDR 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 Med Med Med Med Med Med Med Med Bipin Bipin Bipin Bipin Bipin Bipin Bipin Bipin 1 1 1 1 2 2 2 2 120 277 347 220 50 120 277 347 220 / 240 0.4 0.2 0.2 0.2 0.6 0.3 0.2 0.2 46 46 52 51 73 80 62 71 CHRBFL080/120 CHRBFL080/277 CHRBFL40/347 CHRBFL40/220 50 CHRBFL080/120 CHRBFL080/277 CHRBFL80/347 CHRBFL80/220 FVN 54W T5 HO Med Bipin 2 120 / 277 NFL, FVN, EVF & EVFDR L FVN, EVF & EVFDR EVF & EVFDR 60W 60W 60W 60W 60W 60W 110W 110W 110W 110W T8 T8 T8 T8 T8 T8 T8 T8 1.03 / 0.43 120 / 117 (800ma) (800ma) (800ma) (800ma) (800ma) (800ma) T12 T12 T12 T12 T12 T12 HO HO HO HO HO HO Recessed Recessed Recessed Recessed Recessed Recessed Double Double Double Double Double Double Contact Contact Contact Contact Contact Contact 1 1 1 2 2 2 120 277 220 50 120 277 220 50 0.9 0.5 0.7 1.2 0.5 1.0 79 82 140 133 131 224 CHFBFL120/120 CHFBFL120/277 CHFBFL120/220 50 CHFBFL120/120 CHFBFL120/277 CHFBFL120/220 50 (1500ma) (1500ma) (1500ma) (1500ma) T12 T12 T12 T12 VHO VHO VHO VHO Recessed Recessed Recessed Recessed Double Double Double Double Contact Contact Contact Contact 1 1 2 2 120 277 120 277 1.7 0.6 2.2 0.9 130 137 230 241 CHRBFL220/120 CHRBFL220/277 CHRBFL220/120 CHRBFL220/277 Note: For 3 lamp luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values. For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values. 878 CHRBFL054/UNV www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 878-879.qxp 12/16/2013 6:41 PM Page 879 1L Incandescent Luminaires Hazardous and Non-hazardous Description Page No. Application see page 880 Class I, Division 1 Hazardous Area Luminaires EVI Series Groups C, D see pages 881–889 EV Series Groups A, B, C, D see page 890 Class I, Division 2 and Industrial Luminaires Vaporgard™ Series see page 891 V Series see page 900 NDA Corro•Gard™ Series see page 904 1L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 879 880-881.qxp 12/23/2013 1L 3:12 PM Page 880 Incandescent Luminaires General Information Applications: Table 500.8(C) Identification Numbers Incandescent luminaires are used: • Indoors or outdoors in industrial locations; for general area or spot lighting • In tunnels, building entrances or similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem • Either mounted directly in the conduit system or attached to cast outlet boxes, by means of pendant, ceiling, wall bracket or stanchion mountings • In areas made hazardous by presence of flammable vapors, gases, or dusts Considerations for Selection: Environmental: • What is the area classification (NEC)/(CEC) of the location in which the luminaires will be installed? Maximum Temperature Deg. C 450 300 280 260 230 215 200 180 165 160 135 120 100 85 Deg. F (T Code) 842 572 536 500 446 419 392 356 329 320 275 248 212 185 T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Lighting levels required: • What wattage fixture(s) will provide the desired light level? Physical arrangement: 1L • Type of luminaire mounting needed 880 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Temp. Class Copyright© 2013 Eaton’s Crouse-Hinds Business 880-881.qxp 12/23/2013 3:12 PM Page 881 EVI Series Explosionproof Incandescent Luminaires Factory Sealed 100–500W Medium and Mogul Base Applications: EVI series incandescent luminaires are used: • For Type 4X, marine, wet location and hose down environments. • Where a consistent light level relatively unaffected by extremes in ambient temperature (–40°C to +65°C) is required. • In areas that require lamps to reach full illumination immediately. • In areas that require lamps to be frequently turned on and off. • Indoors and outdoors in locations which are hazardous due to the presence of flammable vapors or gases, ignitible dusts, or ignitible fibers and flyings. • Where a luminaire is required for tough environmental conditions involving corrosives, water, dust and extreme temperatures. • Manufacturing plants, heavy industrial facilities, industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical and platforms. • For lighting of loading docks, tunnels, stairways, storage closets and task lighting. Features: Cl. III & Simultaneous Presence (Max 150W–Med. base) Marine and Wet Locations Type 4X; IP66 1L Certifications and Compliances: • NEC & CEC: Class I, Division 1, Groups C, D Class I, Zone 1, Group IIB Class II, Groups E, F, G Marine Locations, Wet Locations, Enclosure Type 4X, IP66 • UL Listed • cUL Listed (Certified by UL to CSA Standards) • NEC: Class III; Simultaneous Presence • UL Standards: 844 Electric Fixture Hangers for Hazardous Locations 1598 Luminaires 1598A Luminaires for Installation on Marine Vessels • CSA Standards: C22.2 No. 137 Standard Materials: • Body, mounting modules and guard – copper-free aluminum • Globe – heat and impact-resistant glass • Gaskets – silicone • External hardware – stainless steel • Reflectors – Krydon® fiberglass-reinforced polyester Standard Finishes: • Copper-free aluminum – Corro-free™ epoxy powder coat • Stainless steel – Natural • Krydon® reflectors – High reflectance white 1L • Ambient suitability to 65°C. • Standard 90°C rated building wire for 150W max 40°C ambient application – represents more than 75% of all applications. • Type 4X, marine outdoor locations. • Factory sealed – no external seals required. • Quick connect – fixture threads onto the mounting module for easy installation. • One size luminaire for all medium base incandescent lamps through 300W. • One size luminaire for all mogul base incandescent lamps through 500W. • Small compact size – ceiling mount is 133/4" long. • Shock absorbing receptacle. • Easy to assemble and relamp. • Silicone gaskets seal out dirt and moisture. • Epoxy powder coat for corrosion resistance. • Same mounting modules as used with the EVM and EVLP series. Cl. I, Div. 1, Groups C, D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E, F, G (Max 150W–Med. base) Electrical Ratings: Sources/Wattages • Medium Base – Maximum 300W (PS25) • Mogul Base – Maximum 500W (PS40) Voltages • Medium Base 120V (250V with suffix /250) • Mogul Base 277V Hub Size • 3/4" or 1" NPT pendant, ceiling, wall mount • 3/4" NPT bulkhead mount Options: Description • 250V luminaire for export applications (medium base only) Suffix /250 Accessories: • Reflectors – For Ordering by Components see page 883. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 881 882-883.qxp 12/16/2013 1L 6:41 PM Page 882 EVI Series Explosionproof Incandescent Luminaires Factory Sealed 100–500W Medium and Mogul Base Cl. I, Div. 1, Groups C, D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E, F, G (Max 150W–Med. base) Cl. III & Simultaneous Presence (Max 150W–Med. base) Marine and Wet Locations Type 4X; IP66 EVI501 Series Mogul Base with EV503 Guard (Max. 500W PS40) EVIA2501 EVIA3501 Hub Size 3 /4" 1" Ceiling Mount 3 /4" 1" EVICX2301 EVICX3301 EVICX2501 EVICX3501 Wall Mount 3 /4" 1" EVIBX2301 EVIBX3301 EVIBX2501 EVIBX3501 Bulkhead Mount 3 /4" 1" EVIBH2301 — — — Stanchion Mount 11/4" EVIJ4301 EVIJ4501 EVI301 EVI501 1L Mounting Style Pendant Mount EVI301 Series Medium Base with EV505 Guard (Max. 300W PS25) EVIA2301 EVIA3301 Luminaire with Guard Less Mounting Module Note: 882 Medium base luminaires (EVI301 Series) – For A19 lamps up to 100W, use Leviton socket extension Leviton catalog number 2005. Mogul base luminaires (EVI501 Series) – For PS30 medium base lamps, use Eaton's Wiring Devices socket adapter catalog number 332. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 882-883.qxp 12/16/2013 6:41 PM Page 883 EVI Series Explosionproof Incandescent Luminaires 1L Ordering By Components Factory Sealed 100–500W Medium and Mogul Base EVI Luminaires are available in components. A complete luminaire consists of: I. Mounting Module II. EVI Luminaire Body and Globe Assembly III. Guard, Reflector I. Mounting Module: Type Pendant Conduit Cat. # 3 /4" 1" EVMP2 EVMP3 Ceiling and Wall Box 3 /4" 1" EV22 EV33 Wall Bracket Arm 3 /4" 1" EV22 & EV87 EV33 & EV87 Stanchion 11/4" EVMJ4 Bulk Head 3 /4" EVIJ2 II. Luminaire Body and Globe Assembly with Guard: Type Cat. # Medium Base EVI301 Mogul Base EVI501 III. Guards and Reflectors: Type Cat. # Guard – Fits EVI301 Series (medium base) EV505 Guard – Fits EVI501 Series (mogul base) EV503 Dome Reflector – Fits EVI301 Series (medium base) RD636 Angle Reflector – Fits EVI301 Series (medium base) RA636 Dome Reflector – Fits EVI501 Series (mogul base) RD739 Angle Reflector – Fits EVI501 Series (mogul base) RA739 1L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 883 884-885.qxp 12/16/2013 1L 6:42 PM Page 884 EVI Series Explosionproof Incandescent Luminaires Family Tree Temperature Performance Data Factory Sealed 100–500W Medium and Mogul Base Temperature Performance Data: Type Watts/Lamp Class I, Div. 1 (Class I, Zone 1) Ambient EVI301 Medium Base 100W/A21 or A19 150W/A21 200W/A23 or A25 300W/PS25 200W/PS30 300W/PS35 500W/PS40 40°C T4 T4 T3 T3 T4A T4 T3A 65°C T3C T3C T2C T2C T4 T3C T3 Simultaneous Presence Ambient Supply Wire Temp (°C) Ambient 40°C T3C T3C — — T3A — — 40°C T3C T3C — — T3A — — 40°C 90°C 90°C 105°C 105°C 90°C 90°C 105°C 1L EVI501 Mogul Base 55°C T3C T3C T2D T2D T4 T3C T3 Class II Ambient 884 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 55°C 105°C 105°C 125°C 125°C 90°C 90°C 125°C 65°C 125°C 125°C 125°C 125°C 105°C 105°C 125°C 884-885.qxp 12/16/2013 6:42 PM Page 885 EVI Series Explosionproof Incandescent Luminaires 1L Medium Base Dimensions and Weights Factory Sealed 100–500W Medium and Mogul Base Medium Base EVI Luminaire Dimensions In Inches: Pendant Mount Stanchion Mount Ceiling Mount Wall Mount Bulkhead Mount 1L Medium Base Net Luminaire Weights (lbs.): EVI301 with guard 11 lbs. Add mounting modules: Pendant Ceiling Wall Bulkhead Stanchion 1.0 2.0 4.5 2.2 2.5 lbs. lbs. lbs. lbs. lbs. www.crouse-hinds.com Add for reflectors: RD636 (Dome Reflector, Small) RA636 (Angle Reflector, Small) RD739 (Dome Reflector, Small) RA739 (Angle Reflector, Small) US: 1-866-764-5454 CAN: 1-800-265-0502 1.5 1.0 2.0 1.4 lbs. lbs. lbs. lbs. Copyright© 2013 Eaton’s Crouse-Hinds Business 885 886-887.qxp 12/16/2013 1L 6:42 PM Page 886 Mogul Base Dimensions and Weights EVI Series Explosionproof Incandescent Luminaires Factory Sealed 100–500W Medium and Mogul Base Mogul Base EVI Luminaire Dimensions In Inches: Pendant Mount Ceiling Mount Stanchion Mount 1L Wall Mount Mogul Base Net Luminaire Weights (lbs.): EVI501 with guard 24 lbs. Add mounting modules: Pendant Ceiling Wall Bulkhead Stanchion 1.0 2.0 4.5 2.2 2.5 886 www.crouse-hinds.com lbs. lbs. lbs. lbs. lbs. US: 1-866-764-5454 Add for reflectors: RD636 (Dome Reflector, Small) RA636 (Angle Reflector, Small) RD739 (Dome Reflector, Small) RA739 (Angle Reflector, Small) CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1.5 1.0 2.0 1.4 lbs. lbs. lbs. lbs. 886-887.qxp 12/16/2013 6:42 PM Page 887 EVI Series Explosionproof Incandescent Luminaires Photometric Data 1L Factory Sealed 100–500W Medium and Mogul Base Medium Base Luminaire with Globe and Guard EVICX2301 Lamp: 300W/PS25 Incandescent Medium Base Luminaire with Globe and Dome Reflector (Less Guard) EVICX2300 Lamp: 300W/PS25 Incandescent 1L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 887 888-889.qxp 12/16/2013 1L 6:42 PM Page 888 EVI Series Explosionproof Incandescent Luminaires Photometric Data Factory Sealed 100–500W Medium and Mogul Base Medium Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVICX2300 Lamp: 300W/PS25 Incandescent Mogul Base Luminaire with Globe and Guard 1L EVIA2501 Lamp: 500W/PS40 Incandescent 888 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 888-889.qxp 12/16/2013 6:42 PM Page 889 EVI Series Explosionproof Incandescent Luminaires Photometric Data 1L Factory Sealed 100–500W Medium and Mogul Base Mogul Base Luminaire with Globe and Dome Reflector (Less Guard) EVIA2500 Lamp: 500W/PS40 Incandescent Mogul Base Luminaire with Globe and Angle Reflector (Less Guard) EVIA2500 Lamp: 500W/PS40 Incandescent 1L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 889 890-891.qxp 12/23/2013 1L 3:12 PM Page 890 Cl. I, Div. 1 and 2, Groups A, B, C, D – Pendant Mount Cl. I, Div. 1 and 2, Groups B, C, D – Ceiling and Bracket Mount Wet Locations NEMA 3, 3R EV Incandescent Luminaires Factory Sealed Applications: EV292 Series luminaires are used: • To provide incandescent lighting in locations made hazardous due to the presence of hydrogen, gases or vapors of an equivalent hazard, such as manufactured gas • Hydrogen areas of process industries, missile bases where hydrogen fuel is used and gas manufacturing plants • In areas of lesser hazard than indicated above • EVA292 pendant mount luminaire is also suitable for use in locations made hazardous due to the presence of acetylene Features: • Flametight threaded joints – no external seal needed • Easy to assemble and relamp • Shock absorbing receptacle • Gasket seals out dirt and liquids • Positive locking of globe holder • Heat and impact resistant globe • Inner reflector eliminates upward spill light • Lightweight • Corrosion resistant • Dome and 30° angle reflectors available Certifications and Compliances: 1L • NEC/CEC: Class I, Divisions 1 and 2, Groups A, B, C, D – pendant mount Class I, Divisions 1 and 2, Groups B, C, D – ceiling and bracket mount • UL Standard: 844 • CSA Standard: C22.2 No. 137 Standard Materials: Pendant style with RD725 dome reflector Pendant style with RA725 30° angle reflector Pendant style without reflector Ordering Information: Style Max. Lamp Size Without Dome Hub Reflector Reflector Size (In.) Cat. # Cat. # Pendant 300 watt, PS-30 (medium base) With Guard 3 Ceiling 300 watt, PS-30 (medium base) With Guard 3 Bracket 300 watt, PS-30 (medium base) With Guard 3 30° Angle Reflector Cat. # /4 EVA292 RD725 RA725 /4 EVCX292 RD725 RA725 /4 EVBX292 Not Applicable Dimensions In Inches: • Globes – heat and impact resistant glass • Luminaire and bracket arm – copper-free aluminum • Reflectors – Krydon® fiberglass-reinforced polyester • Back box – Feraloy® iron alloy Standard Finishes: • Aluminum – epoxy powder coat • Krydon – high reflectance white • Feraloy – electrogalvanized and aluminum acrylic paint EVA EVBX EVCX EVCX Size Ranges: • 3/ 4" conduit hub Capacity Ranges: • 300 watt, PS-30 medium base lamps Temperature Performance Data: a b c EVA 87/8 163/8 147/8 EVBX EVCX Reflector Type Diameter 87/8 181/8 165/8 87/8 143/8 127/8 Dome 30° Angle 16" 16" Class I Ambient Supply Style UL Temp. °C Wire °C Pendant T3A 25 / 40 150°C Ceiling T3A 25 / 40 150°C Bracket T3A 25 / 40 150°C Note: Photometric curves and data are the same as shown for EV Groups C, D series. 890 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 890-891.qxp 12/23/2013 3:12 PM Page 891 Cl. I, Div. 2, Groups A, B, C, D (All mounting except stanchion) Wet Locations NEMA 3, 3R VAPORGARD™ Incandescent Luminaires Applications: Vaporgard series incandescent luminaires are used: • Indoors or outdoors in industrial locations where enclosed and gasketed fixtures are required • In tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem • For flush or surface mounting on ceiling or wall; pendant or in conduit systems; with or without a cast outlet box Features: Certifications and Compliances: • Wet locations • NEC/CEC: Class I, Division 2 • UL Standard: 1598 • CSA Standard: C22.2 No. 9 • UL/CSA Fixture Fitting Standard Materials: • Bodies and guards – copper-free aluminum • Globes -Heat and impact resistant tempered glass -Colored glass non-tempered (G55, G56, G57, G58) -Plastic polycarbonate (G63, G65, G67) • Reflectors – Krydon® fiberglassreinforced polyester Standard Finishes: • Bodies and guards – epoxy powder coat • Krydon material – high reflectance white Options: The following options are available from the factory by adding suffix to fixture Cat. No.: Description Suffix • Teflon coating on globe for increased shatter protection (G24 globe 200 watt series only) ............ S808 • 250V nameplate for export applications............... /250 • Plastic polycarbonate see globe .................................... page 894 1L • Designed to exclude dirt, moisture and corrosive vapors from the interior of the luminaires and the conduit system • There are no screws to remove as the shock-absorbing socket strap is keyhole slotted and removes quickly for ease of wiring • The glass globe-guard assembly is installed and/or removed as a unit, making it necessary to handle only one piece in relamping • There are no crevices to accumulate a dirt or dust build-up and fixture has an attractive finish with a smooth, dust and dirt shedding design • Configurated glass globe has vertical fluting and stippled bottom which provides for more even light distribution and glare elimination • For non-hazardous locations, shatterproof plastic polycarbonate globes are available for use with the 200 watt series • Reversible offset socket mounting strap permits use of various size lamps while holding light center in same position for maximum light output and efficiency • Shock absorbing medium base lamp socket Krydon® fiberglass-reinforced polyester reflectors: • Reflectance is equivalent to the finest porcelain enamel • Cannot corrode – no enamel to chip and rust • Ultraviolet inhibitors are incorporated in the material to prevent discoloration and brittleness 1L Ratings (Electrical/Size): • Up to 300 watt, PS-30 medium base lamp • 1/2" to 11/4" hubs • 120V nameplate is standard – for NEC compliance • 250V nameplate is optional. Supplied when ordered with suffix: /250 Class I, Division 2 Temperature Performance Data: (Based on 40°C ambient) Lamp Watts 150 200 300 www.crouse-hinds.com T-Number Supply Wire °C T2A T2B T2B 150°C 200°C 150°C US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 891 892-893.qxp 12/16/2013 6:43 PM Page 892 VAPORGARD™ Incandescent Luminaires 1L Cl. I, Div. 2, Groups A, B, C, D Wet Locations NEMA 3, 3R Enclosed and Gasketed Pendant Mount – VDA Series Series Max. Lamp Size Complete Cat. # with globe/guard Luminaire Components Cat. #s Pendant Body Globe Guard 150 150 150 150 watt A-21 VDA15GP VDA25GP VDA35GP VDA15 VDA25 VDA35 G54 G54 G54 P50 P50 P50 3 /2" /4" 1" 200 200 200 200 watt A-23 VDA12GP VDA22GP VDA32GP VDA12 VDA22 VDA32 G24 G24 G24 P21 P21 P21 /2" /4" 1" 300 300 300 300 watt PS-25 & PS-30 VDA13GP VDA23GP VDA33GP VDA13 VDA23 VDA33 G34/G251 G34/G251 G34/G251 P22 P22 P22 Max. Lamp Size Complete Cat. # with globe/guard Luminaire Components Cat. #s Thru-Feed Body Globe Guard VDC25GP VDC25 G54 P50 VDC22GP VDC22 G24 P21 VDC23GP VDC23 G34/G251 P22 Max. Lamp Size Complete Cat. # with globe/guard Luminaire Components Cat. #s Lamp Socket Body Globe Guard 150 watt A-21 200 watt A-23 300 watt PS-25 & PS-30 VXH15GP VXH15 G54 P50 VXH12GP VXH12 G24 P21 VXH13GP VXH13 G34/G251 P22 Max. Lamp Size Complete Cat. # with globe/guard Luminaire Components Cat. #s Lamp Socket Body Globe Guard Junction Box VXHF25GP VXH15 G54 P50 VXF20 VXHF22GP VXH12 G24 P21 VXF20 VXHF23GP VXH13 G34/G251 P22 VXF20 Hub Size /2" 3 /4" 1" 1 1 1 3 Thru-Feed – VDC Series Hub Size Series /2 or 3/4" 150 /2 or /4" 200 /2 or 3/4" 300 1 1 3 1 150 watt A-21 200 watt A-23 300 watt PS-25 & PS-30 Ceiling Mount for Recessed 4" Round Box – VXH Series 1L Series 150 200 300 Ceiling Mount with Junction Box – VXHF Series Hub Size Series /2 or 3/4" 150 /2 or 3/4" 200 /2 or 3/4" 300 1 1 1 150 watt A-21 200 watt A-23 300 watt PS-25 & PS-30 Note: All fixtures supplied with 1/2" reducers, except for pendant mount. 892 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 892-893.qxp 12/16/2013 6:43 PM Page 893 VAPORGARD™ Incandescent Luminaires Cl. I, Div. 2, Groups A, B, C, D Wet Locations NEMA 3, 3R 1L Enclosed and Gasketed Wall Mount – VXHT Series Hub Size Series /2 or 3/4" 150 /2 or 3/4" 200 /2 or 3/4" 300 1 1 1 Max. Lamp Size 150 watt A-21 200 watt A-23 300 watt PS-25 & PS-30 Complete Cat. # with globe/guard Luminaire Components Cat. #s Wall Bracket Mounting Module Body Globe Guard VXHT25GP VXT20 VXH15 G54 P50 VXHT22GP VXT20 VXH12 G24 P21 VXHT23GP VXT20 VXH13 G34/G251 P22 Wall Mount – Adapter Kit Description Cat. # Mounts wall mount VXHT Series to a 4" Round Box VXT K1 Wall Mount with Junction Box – VXHBF Series Hub Size Series /2 or 3/4" 150 /2 or /4" 200 /2 or 3/4" 300 1 1 1 3 Junction Box VXHBF25GP VXT20 VXH15 G54 P50 VXF20 VXHBF22GP VXT20 VXH12 G24 P21 VXF20 VXHBF23GP VXT20 VXH13 G34/G251 P22 VXF20 Max. Lamp Size Complete Cat. # with globe/guard Luminaire Components Cat. #s Stanchion Mounting Module Body Globe Guard 150 watt A-21 200 watt A-23 300 watt PS-25 & PS-30 VXHA45GP VXA4 VXH15 G54 P50 VXHA42GP VXA4 VXH12 G24 P21 VXHA43GP VXA4 VXH13 G34/G251 P22 Max. Lamp Size 150 watt A-21 200 watt A-23 300 watt PS-25 & PS-30 1L Complete Cat. # with globe/guard Luminaire Components Cat. #s Wall Bracket Mounting Module Body Globe Guard Stanchion Mount – VXHA Series Hub Size 11/4" 11/4" 11/4" Series Note: All fixtures supplied with 1/2" reducers, except for pendant mount. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 893 894-895.qxp 12/16/2013 6:43 PM Page 894 VAPORGARD™ Incandescent Luminaires 1L Parts and Accessories Medium Base Lamp Receptacle with Strap Plastic Globes✪ Globes‡ and Guards Shock Absorbing Description Cat. # Shock Absorbing Medium Base Lamp Receptacle with Strap V84 Shatterproof polycarbonate plastic globe† 150 and 200W globe 300W globe Applications: Max. Lamp Size Reflectors Color Clear (heatresisting) Green Blue Red Amber Dome 200 Watt, A-23, 150 Watt, A-25, A-21 PS-25 Cat. # Cat. # 300 Watt, PS-25, PS-30■ Cat. # G54 G24 G34G251 G55* G56* G57* G58* G25 G26 G27 G28 Guards for Glass Globes (Not for use with plastic globes) 1L 30° Angle Max. Lamp Size Dome Cat. # 30° Angle Cat. # 150 watt, A-21 RD64 RA64 200 watt, A-23, A-25, PS-25 and 300 watt, PS-30 RD71 RA71 VXFT – 5 Hubs, 4 Plugs Guard P50 and P21 Guard P22 For use in: • Food processing plants and canneries, dairies, breweries and bakeries • Emergency lighting Features: • Shatterproof, which precludes contamination of food products with broken particles of glass • Designed to comply with U.S. Dept. of Agriculture specification for food processing plants • Provides protection against vandalism, with resultant lower replacement and maintenance costs • Particularly adaptable for use on emergency police or fire alarm boxes • Same size as G24 series glass globes. Existing installations can be changed to plastic globes simply by replacing globe • For use with 200 watt series luminaires such as VDA22, etc. • For use without guard Color Max. Wattage, Lamp Size Cat. # Natural Green Red 200 watt, A-23 200 watt, A-23 200 watt, A-23 G63 G65 G67 Note: Polycarbonate globes for non-hazardous locations only. Hub Size (In.) Cat. # /2 3 /4 VXFT10 VXFT20 1 Max. Lamp Size Cat. # 150 watt, A-21 200 watt, A-23, A-25, PS-25 300 watt, PS-30 (with G251 only) P50 P21 P22 Mounting Adapter Kit For use when rear wiring entry is required. Use in lieu of VXF10 or VXF20. VXT-K1 †Prior to wash-down, globes must be cool. ✪Lamp must be mounted in vertical position base up to 45°C (stanchion) only. *With G55, G56, G57, G58 color globes, maximum lamp size is 60 watt for outdoor applications. §G24 is available with a TEFLON® coating for increased shatter protection by adding suffix S808 (stanchion) only. ■Globe G251 required when guard P22 is used. Use globe G34 when guard is not used. ‡All glass globes are configured type, having fluted side and stippled bottom. 894 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Description Cat. # Allows for the mounting of nonEaton's Crouse-Hinds outlet boxes to the VXT20 wall mount bracket and VXH ceiling mount bracket VXT K1 Copyright© 2013 Eaton’s Crouse-Hinds Business Page 895 6:43 PM 12/16/2013 894-895.qxp 150W VDA15 VDA25 VDA35 200W VDA12 VDA22 VDA32 300W VDA13 VDA23 VDA33 PENDANT VDA/VFA FLUORESCENT VFA122 VFA222 VFA322 300W VDC23 FLUORESCENT VFC222 VXH12 VXH13 200W VFH122 FLUORESCENT 300W VXH15 150W G24 P21 PLATE 0305729 VXT-K1 GASKET 0305017 150W VXHBF25 200W VXHBF22 300W VXHBF23 1L RA71 CLEAR HEAT RESISTING WALL & JUNCTION BOX VXHBF/VFHBF 300W GLOBE WITH GUARD G251 GLOBE & P22 GUARD ADAPTER KIT FOR MOUNTING VXT20 AND VXH15, VXH12, VXH13, VFH122 TO 4" OULET BOX (BY OTHERS) FLUORESCENT VFHF222 RD71 CLEAR HEAT RESISTING G34 300W GLOBE WITHOUT GUARD 300W VXHF23 VXF20 VXFT20 (ORDER SEPARATELY) VXH15 VXH12 VXH13 VFH122 200W VXHF22 VXHF/VFHF BOX MOUNTING 150W VXHF25 VXH1/VFH1 BOX MOUNTING RA64 (NO GUARD AVAILABLE WHEN ORDERED WITH PLASTIC GLOBE) G24 CLEAR HEAT RESISTING G25 GREEN G26 BLUE G27 RED G28 AMBER G63 CLEAR PLASTIC POLYCARBONATE G65 GREEN PLASTIC POLYCARBONATE G67 RED PLASTIC POLYCARBONATE FLUORESCENT & 200W GLOBE & GUARD VDC/VFC P50 G54 150W GLOBE & GUARD THRU FEED 150W 200W VDC25 VDC22 G54 CLEAR HEAT RESISTING G55 GREEN G56 BLUE G57 RED G58 AMBER RD64 VXT20 VXH15 VXH12 VXH13 VFH122 VFHBF222 FLUORESCENT 0305016 GASKET VXF20 VXFT20 300W 200W 150W VXHT25 VXHT22 VXHT23 WALL MOUNT VXHT/VFHT FLUORESCENT VFHT222 150W 300W VXA4 VXH15 VXH12 VXH13 VFH122 200W VXHA45 VXHA42 VXHA43 VFHA422 FLUORESCENT VXHA4/VFHA4 ANGLE ADAPTER STANCHION MOUNT 895 Copyright© 2013 Eaton’s Crouse-Hinds Business CAN: 1-800-265-0502 US: 1-866-764-5454 www.crouse-hinds.com 1L Family Tree VAPORGARD™ Incandescent Luminaires 896-897.qxp 1L 12/16/2013 6:43 PM Page 896 Photometric Data VAPORGARD™ Incandescent Luminaires Luminaire VXHA45GPRA Luminaire With Globe, 30° Angle Reflector and With or Without Guard Lamp: 150W/A-21 Total Bare Lamp Lumens: 2850 Total Lumens Eff. % With Guard 1490 52.3 Without Guard 1881 66.0 Lamp: 100W/A-21 through 200W/A-23 Total Bare Lamp Lumens: 4000 All data provided is for 200W/A-23 incandescent lamp. Use following candlepower/lumen multipliers for other lamp sizes: 100W 0.42; 150 W0.7 Measurements taken from A-A' plane. Measurements taken from A-A' plane. Luminaire VXHA42GPRA Lamp: 300W/PS-30 Total Bare Lamp Lumens: 6300 Total Lumens Eff. % 3630 57.6 Without Guard 4271 67.8 With Guard Lamp Size Without Guard Total Lumens Eff. % With Guard Total Lumens Eff. % 100W 150W 200W/A-23 200W/PS-25 1141 1890 2700 2174 949 1582 2260 1819 67.5 56.5 1L Luminaire With Globe, 30° Angle Reflector and With or Without Guard Lamp: 300W/PS-30 Total Bare Lamp Lumens: 6000 Measurements taken from A-A' plane. Total Lumens Eff. % With Guard 3360 56.0 Without Guard 3954 65.9 Measurements taken from A-A' plane. 896 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 896-897.qxp 12/16/2013 6:43 PM Page 897 Photometric Data VAPORGARD™ Incandescent Luminaires 1L Lamp: 100W/A-21 through 200W/PS-25 Total Bare Lamp Lumens: 4000 All data provided is for 200W/A-23 incandescent lamp. Use following candela/lumen multipliers for other lamp sizes: 100W 0.42; 150W 0.7; 200W/PS-25 0.82 Luminaire With Globe and With or Without Guard Luminaire With Globe, Dome Reflector and With or Without Guard Example: Zonal Lumens for 200W/A-23 lamp with guard for 0–40° is 948 Zonal Lumens for 150W lamp with guard for 0–40° is 948 x 0.7 = 664. Example: Zonal Lumens for 200W/A-23 lamp with guard for 0–40° is 272 Zonal Lumens for 150W lamp with guard for 0–40° is 272 x 0.7 = 190. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 4 5 80 50 30 10 .654 .608 .567 .549 .486 .432 .471 .400 .345 .407 .333 .277 .353 .282 .228 70 50 30 10 .603 .563 .523 .506 .449 .401 .434 .370 .320 .375 .309 .257 50 50 30 10 .509 .477 .449 .424 .380 .341 .363 .313 .271 30 50 30 10 .422 .399 .376 .349 .315 .285 10 50 30 10 .343 .324 .307 .280 .253 .230 Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .604 .576 .552 .522 .480 .444 .454 .404 .364 .395 .340 .298 .347 .290 .248 .326 .260 .211 70 50 30 10 .591 .565 .543 .512 .472 .440 .445 .398 .361 .387 .336 .296 .339 .286 .246 .312 .260 .218 .273 .220 .179 50 50 30 10 .564 .544 .526 .490 .457 .428 .428 .387 .354 .372 .327 .292 .327 .280 .245 .297 .259 .225 .255 .214 .180 .223 .180 .147 30 50 30 10 .541 .525 .509 .470 .444 .419 .411 .377 .348 .358 .319 .288 .315 .273 .241 .237 .206 .180 .202 .170 .143 .176 .142 .115 10 50 30 10 .521 .507 .494 .452 .429 .409 .396 .367 .342 .345 .311 .283 .304 .268 .238 Room Cavity Ratio 6 7 8 9 10 % Reflectance Eff. Ceil. Wall Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .315 .244 .193 .279 .210 .164 .249 .183 .137 .226 .162 .118 .201 .140 .100 80 50 30 10 .309 .253 .214 .274 .220 .184 .244 .192 .155 .222 .170 .135 .193 .142 .110 70 50 30 10 .289 .225 .177 .257 .194 .150 .230 .170 .127 .208 .150 .110 .185 .130 .093 70 50 30 10 .303 .250 .211 .270 .217 .181 .241 .191 .154 .219 .168 .135 .189 .142 .110 50 50 30 10 .242 .189 .150 .215 .163 .126 .192 .143 .106 .175 .126 .092 .156 .109 .077 50 50 30 10 .291 .245 .209 .260 .212 .179 .232 .186 .153 .211 .166 .134 .184 .139 .109 30 50 30 10 .198 .155 .123 .175 .134 .102 .158 .116 .086 .143 .103 .075 .128 .088 .061 30 50 30 10 .281 .239 .207 .250 .209 .177 .225 .182 .152 .204 .162 .133 .178 .136 .107 10 50 30 10 .157 .122 .096 .140 .106 .080 .124 .091 .066 .114 .080 .057 .101 .068 .045 10 50 30 10 .272 .234 .205 .243 .205 .175 .217 .179 .150 .198 .159 .131 .173 .134 .106 % Reflectance Eff. Ceil. Wall www.crouse-hinds.com US: 1-866-764-5454 % Reflectance Eff. Ceil. Wall CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1L Room Cavity Ratio 1 2 3 897 898-899.qxp 12/16/2013 6:44 PM Page 898 VAPORGARD™ Incandescent Luminaires 1L Photometric Data Lamp: 300W/PS-30 Total Bare Lamp Lumens: 6000 Luminaire With Globe Only Luminaire With Globe and Dome Reflector Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% 1L % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .692 .644 .602 .582 .515 .459 .499 .425 .367 .431 .354 .295 .373 .300 .243 70 50 30 10 .636 .594 .552 .534 .475 .425 .458 .392 .339 .396 .327 .273 50 50 30 10 .532 .500 .470 .444 .398 .358 .380 .328 .285 30 50 30 10 .437 .412 .389 .362 .326 .295 10 50 30 10 .350 .331 .313 .285 .258 .235 Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .766 .734 .706 .671 .621 .579 .587 .528 .482 .514 .448 .398 .454 .385 .334 .345 .276 .223 70 50 30 10 .750 .720 .694 .657 .610 .573 .577 .521 .477 .505 .444 .395 .443 .380 .332 .327 .272 .229 .286 .230 .188 50 50 30 10 .717 .693 .672 .630 .592 .558 .555 .507 .468 .485 .432 .390 .429 .372 .329 .308 .268 .234 .264 .222 .186 .230 .186 .152 30 50 30 10 .688 .670 .651 .606 .575 .546 .535 .494 .460 .468 .422 .385 .414 .364 .325 .241 .210 .183 .205 .172 .145 .179 .144 .116 10 50 30 10 .663 .647 .632 .584 .557 .534 .516 .482 .452 .452 .412 .379 .400 .357 .321 Room Cavity Ratio 6 7 8 9 10 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .333 .258 .205 .295 .223 .173 .263 .194 .145 .238 .170 .125 .212 .147 .105 80 50 30 10 .404 .337 .289 .360 .294 .250 .322 .258 .212 .293 .229 .185 .254 .191 .151 70 50 30 10 .305 .238 .188 .271 .204 .158 .241 .178 .133 .219 .157 .115 .194 .136 .097 70 50 30 10 .397 .333 .285 .354 .290 .246 .317 .256 .211 .288 .227 .185 .249 .191 .151 50 50 30 10 .253 .198 .157 .224 .170 .132 .200 .148 .110 .181 .131 .095 .162 .113 .079 50 50 30 10 .383 .326 .283 .342 .284 .244 .306 .250 .209 .279 .223 .184 .243 .187 .150 30 50 30 10 .204 .160 .127 .180 .138 .105 .162 .119 .088 .146 .105 .075 .130 .090 .061 30 50 30 10 .371 .320 .281 .330 .280 .241 .297 .245 .208 .270 .218 .182 .235 .184 .148 10 50 30 10 .158 .123 .096 .141 .106 .079 .124 .091 .066 .114 .080 .055 .101 .067 .044 10 50 30 10 .359 .313 .277 .322 .275 .239 .288 .241 .206 .262 .215 .180 .229 .181 .146 % Reflectance Eff. Ceil. Wall 898 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 % Reflectance Eff. Ceil. Wall % Reflectance Eff. Ceil. Wall Copyright© 2013 Eaton’s Crouse-Hinds Business 898-899.qxp 12/16/2013 6:44 PM Page 899 VAPORGARD™ Incandescent Luminaires 1L Dimensions Dimensions in Inches a b c d e f g h j 150 watt, A-21 127/8 111/8 53/8 313/16 87/16 12 813/16 9 41/2 200 watt, PS-25 300 watt, PS-30 167/8 145/8 6 4 91/8 14 101/2 1013/16 611/16 167/8 145/8 6 4 91/8 14 12 131/8 611/16 VDA Series VDC Series VXH and VXHF Series (Omit box for VXF Series) 1L VXHT and VXHBF Series (Omit box for VXHB series) Dimensions in Inches Max. Lamp Size 150 watt, A-21 200 watt, A-23, A-25, PS-25 and 300 watt, PS-30 a 53/8 6 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 899 900-901.qxp 12/16/2013 6:44 PM Page 900 Wet Locations NEMA 3, 3R V-Series Incandescent Luminaires 1L Enclosed and Gasketed Applications: Standard Materials: V-Series incandescent luminaires are used: • Indoors or outdoors in industrial locations where enclosed and gasketed fixtures are required • In tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem • For flush or surface mounting on ceiling or wall, with or without a cast outlet box, pendant or in conduit systems • • • • Features: Bodies – Feraloy® iron alloy Guards – copper-free aluminum Globes – glass Reflectors – Krydon® fiberglassreinforced polyester material reflectors Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural • Krydon® material – high reflectance white Options: • Designed to exclude dirt, moisture and corrosive vapors from the interior of the fixtures and the conduit system • Several body styles provide a wide variety of mountings, while all use the same globes, guards and optional accessories • Rugged and corrosion resistant Size Ranges: Certifications and Compliances: • 3/4 hubs • Maximum wattage lamp: – Glass globes 150W, A23 – Polycarbonate 75W, A33 Description Corro-free™ epoxy powder coat Suffix S752 Plastic polycarbonate globe Order separately. See below 1L • Wet locations • NEMA: 3, 3R • UL Standard: 1598 Description VDA VC VG VJ VD Cat. # Cat. # Cat. # Cat. # Cat. # With plain globe and guard VDA2759 VC2759 VG2759 VJ2759 VD2759 Without globe and guard VDA275 VC275 VG275 VJ275 VD275 Glass Globes and Guards Polycarbonate Globes Applications: Polycarbonate globes are used: • In food processing plants, canneries, dairies, breweries and bakeries • In emergency lighting • Emergency police and fire alarm boxes V63 Color Clear (heat resisting) Green Blue Red Amber 900 V911 Cat. # Globe Size V63 6 /4" 3 Cat. # V911 VN72 VN73 VN75 VN76 www.crouse-hinds.com US: 1-866-764-5454 Features: • Polycarbonate globes are shatterproof, preclude contamination of food products with broken particles of glass • Comply with U.S. Dept. of Agriculture specification for food processing plants CAN: 1-800-265-0502 V470 Color Cat. # Natural Red V470 V475 Copyright© 2013 Eaton’s Crouse-Hinds Business 900-901.qxp 12/16/2013 6:44 PM Page 901 1L Incandescent Luminaires Accessories and Parts For V-Series Reflectors Receptacles Krydon® – fiberglass-reinforced polyester (Must be used with V911 Guard) (medium base) Dome Description Cat. # Medium Base Receptacle V46 Gasket Angle Lamp Size Dome 50–150W 30°Angle 50–150W Note: Dia. Cat. # 12" RD60 12" RA60 Description Cat. # Gasket GASK213 Angle reflector cannot always be used with bracket style fixtures. Check distance from mounting surface to center of body against reflector size to determine if reflector will fit. 1L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 901 902-903.qxp 12/16/2013 6:44 PM Page 902 V-Series Incandescent Luminaires 1L Enclosed and Gasketed Dimensions Dimensions In Inches: VC VD a c d h k /8 7 /8 311/16 311/16 4 4 63/16 63/16 49/16 49/16 7 Hub Size 1 /2 3 /4 a b c g h k 415/16 415/16 43/16 43/16 515/16 63/16 21/2 23/4 63/16 63/16 49/16 49/16 1L Hub Size 1 /2 3 /4 VDA VG Hub Size 1 /2 3 /4 902 VJ c h k 47/8 47/8 63/16 63/16 49/16 49/16 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Hub Size 1 /2 3 /4 b c d e h k 113/16 113/16 47/8 47/8 3 /8 3 /8 53/8 53/8 63/16 63/16 49/16 49/16 Copyright© 2013 Eaton’s Crouse-Hinds Business 902-903.qxp 12/16/2013 6:44 PM Page 903 V-Series Incandescent Luminaires 1L Photometric Data Enclosed and Gasketed Luminaires V-Series Lamp: 150W/A23 Clear Total Bare Lamp Lumens: 2800 All data provided is for 150W incandescent lamp. Use following candela/lumen multipliers for the other lamp sizes: 100W – 0.61 Example: Zonal lumens for 150W lamp for 0–40° with guard is 252. Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 50 30 10 .659 .623 .591 .558 .504 .458 .479 .417 .367 .416 .349 .298 .361 .298 .248 70 50 30 10 .609 .577 .545 .515 .466 .426 .442 .386 .342 .384 .324 .278 .336 .275 .230 50 50 30 10 .515 .491 .469 .434 .397 .364 .372 .328 .293 .321 .274 .238 .282 .234 .197 30 50 30 10 .429 .411 .395 .359 .332 .307 .307 .274 .245 .264 .228 .198 .232 .194 .165 10 50 30 10 .350 .337 .325 .290 .269 .251 .246 .221 .199 .211 .183 .160 .185 .156 .132 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .325 .259 .212 .290 .227 .183 .261 .199 .157 .236 .176 .136 .211 .153 .116 70 50 30 10 .299 .240 .197 .268 .210 .170 .241 .186 .146 .219 .164 .127 .194 .143 .108 50 50 30 10 .252 .205 .169 .226 .178 .145 .203 .158 .125 .185 .140 .109 .165 .122 .092 30 50 30 10 .208 .170 .141 .186 .149 .121 .169 .131 .105 .153 .117 .091 .137 .101 .076 10 50 30 10 .167 .136 .114 .151 .121 .098 .135 .106 .084 .124 .094 .073 .110 .081 .060 % Reflectance Eff. Ceil. Wall www.crouse-hinds.com US: 1-866-764-5454 1L 80 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 903 904-905.qxp 12/16/2013 6:45 PM Page 904 Cl. I, Div. 2, Groups A, B, C, D Corrosive Wet Locations NEMA 3, 3R, 4, 4X NDA Corro•Gard™ CorrosionResistant Incandescent Luminaires 1L Applications: Ordering Information: Corro•Gard™ NDA Series Luminaires made of Krydon® fiberglass-reinforced polyester are used to provide incandescent lighting: • Indoors or outdoors in industrial wet or dirty locations and where corrosion is a problem • In marine applications, above and below deck, where salt spray corrosion shortens fixture life • In food and beverage industries where frequent wash-downs are necessary • For walkways, bridges, tunnels, security lighting, cold storage facilities, garages, coal handling areas, shipboard, processing plants, and nuclear generating plant containment areas For Pendant Mounting Features: • Luminaire is molded Krydon for excellent corrosion, heat, and impact resistance • Accommodates all popular incandescent lamps up to 300W, PS-25 • Attractive modern design and color complement other Corro•Gard products • Weighs only 81/2 lbs. complete with lamp and globe • Medium screw base porcelain lamp socket has a vibration absorbing mounting bracket • All joints are gasketed to ensure watertightness • Configured glass globe reduces glare • Corro•Gard reflectors made of Krydon® reflect light better than porcelainized steel; do not yellow or discolor with age; cannot chip, peel, rust or dent 1L ® Hub Size /4" 3 Max. Lamp Size Body Only Cat. # Globe Only Cat. # 300W PS-25 Med. Base 120V NDA22 G24 Body With Globe Cat. # NDA22G Temperature Performance Data: (based on 40°C ambient) Max. Lamp Size 300W Note: T-Number Supply Wire (°C) T2A 150°C Fixtures are not marked with T-Number. Dimensions In Inches: Accessories & Parts Certifications and Compliances: Reflectors (Order separately) • UL Standard: 1598 • Wet Locations • Suitable for 40°C ambient temperature Standard Materials: • Bodies and reflectors – Krydon® fiberglass-reinforced polyester material • Globes – configured heat-resistant glass Standard Finishes: • Bodies – natural • Reflectors – natural, high reflectance white Options: Description TEFLON® coating on G24 globe for increased shatter protection 904 www.crouse-hinds.com Suffix Globe Color Globe Cat. # Clear (heat resisting) Green Blue Red Amber G24 G25 G26 G27 G28 Guard Guard Cat. # Dome P21 30° Angle Replacement Lamp Receptacles with Strap Shock Absorbing Type Cat. # Dome 30° Angle RD725 (RD75) RA725 (RA75) S808 US: 1-866-764-5454 Description Cat. # Replacement Lamp Receptacles NV84 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 904-905.qxp 12/16/2013 6:45 PM Page 905 NDA Corro•Gard™ CorrosionResistant Incandescent Luminaires Photometric Data 1L Lamp: 200W/PS-25 All data provided is for incandescent with 200W/PS-25 lamp. See Multipliers for other wattages and lamp types. Luminaire With Globe Luminaire With Globe and Dome Reflector Luminaire With Globe and 30° Angle Reflector Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 4 5 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 4 5 Total Lumens 2595 50 30 10 .762 .651 .565 .494 .433 .715 .585 .491 .416 .358 .673 .529 .433 .357 .300 80 50 30 10 .809 .703 .615 .541 .481 .773 .647 .550 .470 .408 .742 .601 .499 .416 .354 70 50 30 10 .708 .605 .526 .461 .406 .667 .546 .460 .390 .335 .626 .496 .407 .336 .282 70 50 30 10 .791 .688 .604 .531 .470 .758 .636 .542 .465 .403 .729 .595 .494 .413 .315 50 50 30 10 .608 .519 .452 .395 .292 .576 .473 .399 .339 .250 .547 .432 .356 .295 .248 50 50 30 10 .756 .659 .580 .510 .455 .729 .617 .528 .453 .395 .706 .579 .485 .408 .349 30 50 30 10 .516 .439 .382 .335 .297 .492 .404 .342 .290 .250 .469 .372 .307 .254 .215 30 50 30 10 .726 .634 .558 .492 .439 .705 .599 .514 .442 .385 .684 .566 .477 .402 .344 10 50 30 10 .433 .366 .319 .279 .247 .413 .339 .287 .244 .211 .396 .315 .259 .215 .181 10 50 30 10 .699 .610 .539 .475 .424 .663 .580 .501 .431 .378 .580 .553 .468 .396 .340 0 0 .354 .277 .226 .184 .154 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 9 10 80 50 30 10 .389 .348 .312 .284 .253 .312 .273 .240 .214 .185 .258 .222 .190 .166 .141 70 50 30 10 50 0 0 .647 .536 .451 .378 .323 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 9 10 80 50 30 10 .431 .386 .347 .317 .277 .360 .317 .280 .250 .211 .309 .269 .231 .204 .169 .363 .324 .291 .266 .236 .293 .256 .226 .201 .175 .242 .208 .179 .157 .133 70 50 30 10 .423 .380 .342 .312 .272 .356 .312 .277 .247 .211 .305 .265 .231 .204 .169 50 30 10 .312 .280 .252 .230 .205 .256 .223 .198 .177 .153 .213 .183 .158 .139 .117 50 50 30 10 .408 .368 .331 .302 .265 .348 .305 .272 .243 .207 .303 .263 .229 .202 .167 30 50 30 10 .266 .238 .216 .197 .175 .220 .193 .170 .152 .131 .185 .158 .137 .121 .100 30 50 30 10 .396 .355 .321 .294 .257 .342 .301 .266 .238 .203 .300 .260 .227 .201 .165 10 50 30 10 .223 .201 .180 .166 .147 .185 .163 .144 .129 .110 .156 .135 .116 .102 .084 10 50 30 10 .383 .346 .311 .285 .250 .334 .295 .262 .235 .200 .297 .258 .225 .199 .163 0 0 .132 .112 .096 .084 .068 0 0 .281 .243 .210 .184 .150 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 80.6 Multipliers for Other Lamps Photometric data was developed using a 200 watt/PS-25 inside frosted incandescent lamp (3,220 lumens). For other incandescent watts/lamp size, use the following conversion factors (multipliers): Lamp Lamp Conversion Watts Size Lumens Factor 100 A-19 1750 .54 100 A-21 1690 .52 150 150 A-21 PS-25 2880 2680 .89 .83 200 A-23 4010 1.25 300 PS-25 6360 1.98 Example: Zonal lumens for 200W/PS-25 luminaire with globe and dome reflector for 30–40° is 389. Zonal lumens for 100W/A-21 luminaire with globe and dome reflector for 30–40° is 389 × .52 = 202. Copyright© 2013 Eaton’s Crouse-Hinds Business 905 1L 80 Eff. % 906-907.qxp 12/16/2013 6:46 PM Page 906 1L 1L 906 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 906-907.qxp 12/16/2013 6:46 PM Page 907 2L LED Luminaires Industrial and Hazardous Areas Description Page No. Application/Selection see pages 908–909 Industrial and Hazardous Area LED Luminaires EV LED Series see pages 910–913 Hazard•Gard EVLL Series see pages 914–918 Hazard•Gard® LPL Series see pages 919–921 ® LL48 Series see pages 922–923 Champ® VMV LED Series see pages 924–928 Champ® FMV LED Series see pages 929–932 Vaporgard™ LED Series see pages 933–936 N2LPS Light-Pak™ Emergency Lighting System see pages 937–939 Ex-Lite Series LED Exit Signs see page 940 CCH UX Series LED Exit Signs see page 941 Champ® Pro PVM Series see pages 943–946 Champ® Pro PFM Series see pages 947–948 Champ® Pro PFM25L and 50L Series see pages 949–951 Vaporgard™ Pro P2L Series see pages 952–954 Industrial High Bay LED Series see page 955 Endure™ LED Series see pages 956–957 LED Obstruction Lights and Visual Signals See Obstruction Lighting Guide 2L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 907 908-909.qxp 12/16/2013 6:48 PM Page 908 LED Luminaires 2L Application and Selection Applications: Considerations for Selection: Environmental: • What are the hazardous areas classifications (NEC/CEC) of the locations in which the luminaires will be installed? • Must luminaires be suitable for use in marine, hosedown, corrosive applications? Lighting levels required: • What wattage luminaire(s) will provide the desired light level? Watts HPS, MH & Pulse Start MH Lamps 26 Watts; 30 Watts; 36 Watts Hazardous Area & Other Enviromental Suitabilities NEC, CEC, IEC NEC & CEC Cl. I, Div. 1, Groups C, D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E, F, G Marine and Wet Locations, Type 4X, IP66 NEC Cl. III, Simultaneous Presence Series EV LED Application General Illumination Hazard•Gard EVLL LED General Illumination 80 Watts; 100 Watts; 130 Watts; 151 Watts; 175 Watts NEC & CEC Cl. I, Div. 1, Groups B, C, D Cl. I, Zone 1, Groups IIB + H2, IIB, IIA Cl. II, Groups E, F, G Cl. III, Simultaneous Presence Hazard•Gard LPL LED General Illumination 60 Watts; 85 Watts; 100 Watts; 125 Watts; 150 Watts IEC Zones 1 and 2 (Ex-gas) Zones 21 and 22 (Ex-dust) LL48 Linear LED General Illumination 56 Watts NEC Cl. I, Div. 2, Groups A, B, C, D NEMA 4X, IP66 Marine and Wet Locations Champ® VMV LED General Illumination 41 Watts; 67 Watts; 94 Watts; 114 Watts; 118 Watts NEC & CEC Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, nA nR Cl. II, Groups E, F, G Cl. III Simultaneous Presence Wet Locations, Type 4X, IP66 Champ® FMV LED Outdoor/Indoor Flood Illumination 64 Watts; 89 Watts; 121 Watts; 149 Watts; 179 Watts NEC & CEC Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III Simultaneous Presence Wet Locations, Type 4X, IP66 Vaporgard™ LED Targeted Illumination 22 Watts NEC & CEC Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups F, G NEMA 4X N2LPS Light-Pak™ Emergency Illumination Input: 9 Watts max. Lamp: 3 Watts NEC & CEC Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 1 Marine Wet Locations Suitability, Type 4X 2L 2L Luminaires included in this section are designed for use: • In manufacturing plants; heavy industrial, chemical, petrochemical, or pharmaceutical facilities; platforms; loading docks; tunnels 908 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 908-909.qxp 12/16/2013 6:48 PM Page 909 2L LED Luminaires Application and Selection Application Emergency Illumination CCH UX Emergency Illumination 3.2 Watts NEC Cl. I, Div. 2, Groups A, B, C, D IP65, IP66 Wet Locations NEMA 4X Champ® Pro PVM General High Bay/Low Bay Illumination 41 Watts; 67 Watts; 94 Watts; 114 Watts; 118 Watts NEC & CEC UL1598 UL1598A cUL NEMA 4X IP66 Champ® Pro PFM Outdoor/Indoor Flood Illumination 64 Watts; 89 Watts; 121 Watts; 149 Watts; 179 Watts NEC & CEC UL1598 UL1598A cUL NEMA 4X IP66 Champ® Pro PFM 25L and 50L Outdoor/Indoor Flood Illumination 263 Watts; 531 Watts NEC & CEC UL1598 UL1598A cUL NEMA 4X IP66 Vaporgard™ Pro P2L Targeted Illumination 22 Watts NEC & CEC UL1598 UL1598A cUL NEMA 4X IP66 Industrial High Bay LED General Illumination 141 Watts (at 120 VAC); 138 Watts (at 277 VAC) Meets UL1598 and cUL construction requirements Endure™ LED Wall Pack General Illumination 27 Watts; 51 Watts NEC & CEC UL1598 cUL IP66 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Hazardous Area & Other Enviromental Suitabilities NEC, CEC, IEC NEC & CEC Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, AEx em ib IIC Cl. II, Div. 2, Groups F, G Copyright© 2013 Eaton’s Crouse-Hinds Business 2L Series Ex-Lite Watts HPS, MH & Pulse Start MH Lamps 6 Watts 909 910-911.qxp 12/16/2013 2L 6:50 PM Page 910 Cl. I, Div. 1, Groups C, D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E, F, G Cl. III, Simultaneous Presence EV LED Series Explosionproof LED Luminaires Factory-sealed Improve safety, reliability and energy efficiency The enhanced EV LED product offering provides the same durability and reliability of a traditional EV incandescent or HID fixture, coupled with the low cost of ownership and energy efficiency of Eaton's Crouse-Hinds LED technology. Highperformance LEDs and a solid state electronic driver provide light where you need it, at a fraction of the operating costs of HID and incandescent lighting technologies. EV LED Benefits: EV LED Series Luminaires are designed to provide durable and energy-efficient lighting in a variety of applications. Incandescent and HID general illumination models are available, along with a wildlife friendly model and optional DC input voltage. • Easy installation – compact modular fixture attaches onto existing Champ mounting module • Energy-efficient – up to 85% reduction in energy used • Provides up to 50,000 hours rated life – eliminates need for frequent lamp replacement • Contains no mercury or other hazardous substances Applications: 2L • Two lumen outputs for replacement of existing HID and incandescent luminaires • Locations requiring continuous and consistent light levels in extreme ambient temperatures • Areas requiring frequent on-and-off of lights • Where flammable vapors, gases, ignitable dusts, fibers or flyings are present; indoors or outdoors • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist • Type 4X, marine, wet locations and hose-down environments • Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; platforms; loading docks; tunnels; outdoor wall and stanchion mounted general area lighting Certifications & Compliances: Enhance safety and productivity • Instant illumination and re-strike • Better visibility with crisp, white light • T6 temperature rating – safely operate in the most hazardous environments • Cold temperature operation / no warm-up required Reduce operation and maintenance costs Reliable performance in any environment • Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break – greatly reduces the risk of premature failure • Operating ambient -30°C to 55°C (AC), -30°C to 40°C (DC) • Dark sky compliant Standard Materials: • Body, mounting modules and guard – copper-free aluminum with Corro-free™ epoxy powder coat • Globe – heat and impact-resistant glass • Gaskets – silicone • External hardware – stainless steel Electrical Ratings: NEC & CEC • • • • • • • Class I, Division 1, Groups C, D T6 temperature rating at 55°C Class I, Zone 1 & 2, Group IIB Class II, Groups E, F, G Marine and wet locations, Type 4X, IP66 UL Listed cUL Listed (certified by UL to CSA standards) NEC • Class III, simultaneous presence UL Standards • 844 Electric Fixture Hangers for Hazardous Locations • 1598 Luminaire • 1598A Luminaire for Installation on Marine Vessels CSA Standards • C22.2 No. 137 910 www.crouse-hinds.com UL Listed cUL Listed (certified by UL to CSA standards) T6 temperature rating at 55°C Marine and wet locations Type 4X, IP66 US: 1-866-764-5454 Voltage Range Frequency Input Power Input Amps (Max.) Power Factor C201 C701 A201 C201/DC 100-277V 50 / 60 Hz 30W 0.30A 0.98 100-277V 50 / 60 Hz 36W 0.36A 0.99 100-277V 50 / 60 Hz 36W 0.36A 0.98 10-30 VDC 50 / 60 Hz 26W 2.8A 0.99 LED System: • High brightness light emitting diode (LED) arrays • Color temperature: 3000K (CRI 82) and 5600K (CRI 65) options available • Amber color available for wildlife friendly applications • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions • LM-79 and LM-80 reports available CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 910-911.qxp 12/16/2013 6:50 PM Page 911 EV LED Series Explosionproof LED Luminaires Factory-sealed Improve safety, reliability and energy efficiency Cl. I, Div. 1, Groups C, D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E, F, G Cl. III, Simultaneous Presence UL Listed cUL Listed (certified by UL to CSA standards) T6 temperature rating at 55°C Marine and wet locations Type 4X, IP66 2L Ordering Information: Cool Color Temperature Mounting Style Warm Color Temperature W201 Wildlife Friendly C201 C701 Luminaire Only EVLEDC201 EVLEDC701 EVLEDW201 EVLEDW701 W701 EVLEDA201 A201 3 /4" Pendant EVLEDA2C201 EVLEDA2C701 EVLEDA2W201 EVLEDA2W701 EVLEDA2A201 1" Pendant EVLEDA3C201 EVLEDA3C701 EVLEDA3W201 EVLEDA3W701 EVLEDA3A201 3 /4" Ceiling Mount Thru Feed EVLEDCX2C201 EVLEDCX2C701 EVLEDCX2W201 EVLEDCX2W701 EVLEDCX2A201 1" Ceiling Mount Thru Feed EVLEDCX3C201 EVLEDCX3C701 EVLEDCX3W201 EVLEDCX3W701 EVLEDCX3A201 3 /4" Wall Mount Thru Feed EVLEDBX2C201 EVLEDBX2C701 EVLEDBX2W201 EVLEDBX2W701 EVLEDBX2A201 1" Wall Mount Thru Feed EVLEDBX3C201 EVLEDBX3C701 EVLEDBX3W201 EVLEDBX3W701 EVLEDBX3A201 3 /4" Bulkhead Mount EVLEDBH2C201 EVLEDBH2C701 EVLEDBH2W201 EVLEDBH2W701 EVLEDBH2A201 11/4" Stanchion EVLEDJ4C201 EVLEDJ4C701 EVLEDJ4W201 EVLEDJ4W701 EVLEDJ4A201 To order a fixture without a guard, remove ‘1’ from the end of the catalog number (Example: EVLEDAC20 for 3/4" Pendant, No Guard). To order a fixture with 10-30VDC Input Voltage (available on 20 Series Only), add /DC to the end of the catalog number (Example: EVLEDAC201/DC). To order a fixture with colored inserts (available on C20 Series Only), add a "G" (for green) or "R" (for red) to the end of the catalog number (Example: EVLEDAC201G). Family Tree: Stanchion EVMJ4 1-1/4” HUB4 Ceiling EV22 3/4” HUB4 EV33 1” HUB4 Pendant EVMP2 3/4” HUB4 EVMP3 1” HUB4 Wall EV22 & EV87 3/4” HUB4 EV33 & EV87 1” HUB4 Bulkhead EVU 3/4” HUB4 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 2L EVLED with Guard (Luminaire Only) 911 912-913.qxp 12/16/2013 6:51 PM Page 912 2L EV LED Series Explosionproof LED Luminaires Factory-sealed Improve safety, reliability and energy efficiency Cl. I, Div. 1, Groups C, D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E, F, G Cl. III, Simultaneous Presence UL Listed cUL Listed (certified by UL to CSA standards) T6 temperature rating at 55°C Marine and wet locations Type 4X, IP66 Photometrics: POLAR PLOT (EVLEDC701) DISTANCE TO MOUNTING HEIGHT Isofootcandle chart shows illuminance in footcandles at ground level (EVLEDC701) ISOFOOTCANDLE CHART 2L Footcandle Values for Isofootcandle Lines ZONE (DEGREES) LUMENS % OF LUMINAIRE 0-30 451 20.1% 0-40 688 30.6% 0-60 1688 75.1% 0-90 2196 A B C D E F Mtg. Hgt. A B C D E F 10’ 4.00 2.00 1.00 0.50 0.25 0.12 97.7% 12’ 2.78 1.39 0.69 0.35 0.17 0.09 16’ 1.56 0.78 0.39 0.20 0.10 0.05 20’ 1.00 0.50 0.25 0.12 0.06 0.03 25’ 0.64 0.32 0.16 0.08 0.04 0.02 90-180 51 2.3% 0-180 2248 100.0% LUMEN OUTPUT FOR OTHER EV LED LUMINAIRES System Watts Lumens C201 30W 1670 A201 36W 1195 C201/DC 26W 1493 Luminaire Series 912 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 912-913.qxp 12/16/2013 6:51 PM Page 913 EV LED Series Explosionproof LED Luminaires Factory-sealed Improve safety, reliability and energy efficiency Cl. I, Div. 1, Groups C, D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E, F, G Cl. III, Simultaneous Presence UL Listed cUL Listed (certified by UL to CSA standards) T6 temperature rating at 55°C Marine and wet locations Type 4X, IP66 2L Dimensions (inches): Pendant Mount Ceiling Mount ) ) Stanchion Mount 6-3/4 4 13-1/4 5/16 4 12 1-1/4 12-3/4 13-1/2 1 13 13-3/4 12-3/4 1-1/4 conduit 25° 7-1/4 7-1/4 Bulkhead Wall Mount ) 16-1/16 16-13/16 9-1/4 1-5/16 12-9/16 9-7/16 6-3/4 4 4 4 13/32 13/16 2L 5/16 16-1/8 15-3/8 Net Weight (lbs.): EV LED with Guard Add Mounting Modules: Pendant Ceiling Wall Bulkhead Stanchion 11 lbs. 1.0 2.0 4.5 2.2 2.5 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 lbs. lbs. lbs. lbs. lbs. Copyright© 2013 Eaton’s Crouse-Hinds Business 913 914-915.qxp 12/16/2013 2L 6:53 PM Page 914 Cl. I, Div. 1, Groups B, C, D Cl. I, Zone 1, Groups IIB + H2, IIB, IIA Cl. II, Groups E, F, G Cl. III Hazard•Gard® EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination The EVLL LED Family EVLL LED Benefits: Hazard•Gard® EVLL Series LED Luminaires are designed to provide full-spectrum, crisp, white light. Five versions of the EVLL LED are available, providing ideal solutions for a wide range of applications. Industry best for ease of installation Typical Energy Savings Model Equivalent HID Luminaire EVLL5L EVLL7L EVLL9L EVLL11L EVLL13L 100W-150W MH 150W-175W HPS/MH Up to 175W-250W MH 62% 250W-400W HPS/MH 400W HPS/MH PS Applications: 2L • Five lumen outputs for replacement of existing HID luminaires • Locations requiring continuous and consistent light levels in extreme ambient temperatures • Areas requiring frequent on-and-off of lights • Where flammable vapors, gases, ignitable dusts, fibers or flyings are present; indoors or outdoors • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist • NEMA 4X, marine, wet locations, and hose-down environments • Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; platforms; loading docks; tunnels; outdoor wall and stanchion mounted general area lighting UL Listed & CSA Certified IEC / ATEX (Pending) Simultaneous Presence Marine & Wet Locations NEMA 4X, IP66 • Quick-connect design – install and wire the mounting module, then simply screw in the luminaire • Factory-sealed – no external sealing fittings required in Groups B, C, and D • Adapter available for connection to existing Hazard•Gard® EVI, EVLP, and EVM modules Reduce operation and maintenance costs • Energy-efficient – up to 62% reduction in energy used versus equivalent HID fixtures • 60,000 hours rated life – eliminates need for frequent lamp replacement Reliable performance in any environment • Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break – greatly reduces the risk of premature failure • T5 temperature rating • Operating ambient -25°C to 65°C Certifications and Compliances: NEC and CEC • Class I, Division 1, Groups B, C, D • Class I, Zone 1, Groups IIB + H2, IIB, IIA • Class II, Groups E, F, G • Class III, Simultaneous Presence UL Standards • UL844 Electric Fixture Hangers for Hazardous Locations • UL1598 Luminaires • UL1598A Luminaire for Installation on Marine Vessels CSA Standard • CSA C22.2 No. 137 Environmental Ratings • NEMA 4X • IP66 • Marine and Wet Locations IEC and ATEX Certifications and Protection (Pending) • Ex II 2G Ex d IIC (Zone 1, 2) (Pending) • Ex II 2D Ex tD A21 IP66 (Zone 21, 22) (Pending) Standard Materials: • Body and mounting modules – copperfree aluminum with Corro-free™ epoxy powder coat • Lens – shatter-resistant, explosionproof glass • Gaskets – silicone • Guard – stainless steel • External hardware – stainless steel • Factory-sealed* *Refer to Installation and Maintenance Sheet for external seal requirements. LED System: • High brightness light emitting diode (LED) arrays • Color temperature: 3000K (CRI 82) and 5600K (CRI 65) options available • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions • LM-79 and LM-80 reports available Electrical Ratings: Model Voltage Input Amps (Max.) Power Factor Input Power Lumen Output EVLL5L 100-277VAC, 50 / 60 Hz 108-250VDC 0.46-0.82 0.38-0.89 0.99% 1 80W 5625 EVLL7L 100-277VAC, 50 / 60 Hz 108-250VDC 0.51-1.11 0.42-1.15 0.99% 1 100W 6750 EVLL9L 100-277VAC, 50 / 60 Hz 108-250VDC 0.61-1.19 0.56-1.30 0.99% 1 130W 9000 EVLL11L 100-277VAC, 50 / 60 Hz 108-250VDC 0.76-1.56 0.73-1.71 0.99% 1 151W 10500 EVLL13L 100-277VAC, 50 / 60 Hz 108-250VDC 0.78-1.58 0.75-1.73 0.99% 1 175W 13500 914 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 914-915.qxp 12/16/2013 6:53 PM Page 915 Hazard•Gard® EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination Cl. I, Div. 1, Groups B, C, D Cl. I, Zone 1, Groups IIB + H2, IIB, IIA Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IEC / ATEX (Pending) Simultaneous Presence Marine & Wet Locations NEMA 4X, IP66 2L Installation and replacement made simple Modular design - This contractor-friendly design is ideal for both new construction applications and retrofit. These luminaires use the same mounting modules as existing Hazard•Gard® Series luminaires. The quickconnect design facilitates installation - install and wire the mounting module, then screw in your luminaire. Two start Acme threads ease and reduce installation time. High efficiency and lumen output Driver module assembly - High efficiency LED drivers are designed to provide reliable operation in even the harshest environments. Various AC and DC input voltage options are available to suit virtually any drive requirement. Safe, reliable heat transfer Heat sink - Enhanced heat sink design provides safe and effective heat transfer from the LED assembly to the outside environment, ensuring low LED junction temperature, reliability and sustained lumen performance. 2L NEMA 4X rated LED housing assembly - The LED housing is constructed of durable die cast aluminum, providing an efficient thermal path to the heat sink assembly. The impact-resistant lens is sealed from the outside environment and provides ingress protection against water and dust. Multi-die LED arrays are used to provide energy-efficient, long-life white light. www.crouse-hinds.com Optional color temperatures Warm (available on 5L through 11L models only) and cool white color temperatures available. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 915 916-917.qxp 12/16/2013 2L 6:54 PM Page 916 Hazard•Gard® EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination Cl. I, Div. 1, Groups B, C, D Cl. I, Zone 1, Groups IIB + H2, IIB, IIA Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IEC / ATEX (Pending) Simultaneous Presence Marine & Wet Locations NEMA 4X, IP66 Catalog Numbering System: SERIES LAMP OUTPUT LED COLOR MOUNTING MODULE HUB SIZE GUARD VOLTAGE EVLL 5L C A 2 0 /UNV1 SERIES EVLL SUFFIXES Explosionproof Vaportight Low Profile LED Luminaire LAMP OUTPUT 5L 5,625 Lumen Output 7L 6,750 Lumen Output 9L 9,000 Lumen Output 11L 10,500 Lumen Output 13L 13,500 Lumen Output LED COLOR C Cool (5600K nominal) W Warm (3000K nominal) (available on 5L through 11L models only) 2L MOUNTING MODULE A Pendant EVSP BX Wall Bracket EVSW CX Ceiling Mount EVSC 916 J M Blank Stanchion EVSJ Mounting Module Adapter EVSA (See Note #1) No Mounting Module Supplied HUB SIZE 2 3 5 25 32 Blank ⁄4” NPT (Pendant, Ceiling, and Wall Only) 1” NPT (Pendant, Ceiling, and Wall Only) 1 1⁄2” NPT (Stanchion Only) 25 mm (Pendant, Ceiling, and Wall Only) 32 mm (Pendant, Ceiling, and Wall Only) Leave Blank for Mounting Module Adapter and No Mounting Module GUARD 0 1 No Guard Stainless Steel 3 Notes: VOLTAGE (See Note #2) /UNV1 120VAC to 277VAC 50/60 Hz, 108VDC to 250VDC 1. EVSA Adapter for use with existing Eaton’s Crouse-Hinds EVI, EVLP, and EVM mounting modules. SUFFIXES S812 Trunnion Mount 2. Accessory kit EVLL347/480 K1 (step down transformer in separate enclosure) is available for 347V and 480V 60 Hz applications. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 916-917.qxp 12/16/2013 6:54 PM Page 917 Cl. I, Div. 1, Groups B, C, D Cl. I, Zone 1, Groups IIB + H2, IIB, IIA Cl. II, Groups E, F, G Cl. III Hazard•Gard® EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination UL Listed & CSA Certified IEC / ATEX (Pending) Simultaneous Presence Marine & Wet Locations NEMA 4X, IP66 2L Dimensions (In Inches): Ceiling Mount Pendant Mount Wall Mount Stanchion Mount [241.5] 9.51 [80.2] 3.16 [104] [91.3] 4.09 3.59 25° [366.2] [391.6] 14.42 15.42 [334.5] 13.17 [342.4] [367.8] 13.48 14.48 [353] 13.90 [378.4] 14.90 [404.8] Ø 16 [414.4] Ø 16.32 [414.4] Ø 16.32 [345.2] 13.59 [341.9] 13.46 [407.7] 16.05 [454.6] 17.90 [459.5] 18.09 [407.6] Ø 16.05 Ambient Temperature: Weights: Model Lbs. EVLL5L EVLL7L EVLL9L EVLL11L EVLL13L Add Mounting Modules: Pendant Ceiling Stanchion Wall Adapter 51.76 51.81 52.38 53.00 53.00 2.00 3.50 3.00 5.50 2.00 Max. Ambient Temp. ºC Cl. I, Div. 1 Cl. II, Div. 1 & 2 / Simu. Presence Cl. I, Zone 1 EVLL5L 40 55 65 T6 T6 T5 T5 T5 T5 Pending Pending Pending EVLL7L 40 55 65 T6 T6 T5 T5 T5 T5 Pending Pending Pending EVLL9L 40 55 65 T6 T6 T5 T5 T5 T5 Pending Pending Pending EVLL11L 40 55 T6 T6 T5 T5 Pending Pending EVLL13L 40 55 T6 T6 T5 T5 Pending Pending Model Family Tree: EVMJ4 EV22 EV33 EVMP2 EVMP3 EVJ2 2L EV22 EV33 EV87 EVSJ5 EVSA EVSC2 EVSC25 EVSC3 EVSC32 EVSW2 EVSW3 EVSW25 EVSW32 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 EVSP2 EVSP3 EVSP25 EVSP32 Copyright© 2013 Eaton’s Crouse-Hinds Business 917 918-919.qxp 2L 12/16/2013 6:56 PM Page 918 Hazard•Gard® EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination Cl. I, Div. 1, Groups B, C, D Cl. I, Zone 1, Groups IIB + H2, IIB, IIA Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IEC / ATEX (Pending) Simultaneous Presence Marine & Wet Locations NEMA 4X, IP66 Photometric Data: POLAR PLOT CANDELA (EVLL13LCA20/UNV1) DISTANCE TO MOUNTING HEIGHT Isofootcandle chart shows illuminance in footcandles at ground level (EVLL13LCA20/UNV1) 3 2 1 0 -1 -2 -3 -3 -2 -1 0 1 2 3 ISOFOOTCANDLE CHART Footcandle Values for Isofootcandle Lines 2L A B C D E F ZONE (DEGREES) LUMENS % OF LUMINAIRE Mtg. Hgt. A B C D E F 0-30 4221 31.7% 12’ 34.72 13.89 6.94 3.47 1.39 0.69 0-40 6923 52.1% 16’ 19.53 7.81 3.91 1.95 0.78 0.39 0-60 11630 87.5% 20’ 12.50 5.00 2.50 1.25 0.50 0.25 0-90 13500 100.0% 25’ 8.00 3.20 1.60 0.80 0.32 0.16 90-180 0 0% 0-180 13500 100.0% LUMEN OUTPUT FOR OTHER EVLL LED LUMINAIRES Luminaire Series EVLL5L EVLL7L EVLL9L EVLL11L EVLL13L 918 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business System Watts 80W 100W 130W 151W 175W Lumens 5625 6750 9000 10500 13500 918-919.qxp 12/16/2013 6:56 PM Page 919 Hazard•Gard® LPL Series Explosionproof LED Luminaires 2L Zones 1 & 2 (Ex-Gas) IECEx / ATEX Zones 21 & 22 (Ex-Dust) IP66 Zone 1 high power LED pendant for general illumination The LPL LED Family The LPL LED Luminaire is available in five different versions, providing ideal solutions for a wide range of applications. Model Equivalent HID Luminaire Typical Energy Savings LPL04-C60-60W LPL04-C60-85W LPL04-C60-100W LPL06-C60-125W LPL06-C60-150W 70W-100W MH 150W MH 175W MH 175W-250W MH 250W MH 40% Applications: • Zone 1/Zone 2 Ex-Gas and Zone 21/Zone 22 Ex-Dust hazardous areas • Heavy industrial, chemical, petrochemical, or pharmaceutical facilities • Offshore platforms • Shipyards • Electric power • Loading docks • Wastewater treatment plants • Paper mills LPL LED Benefits: Robust construction • Copper-free aluminum housing • Tempered and impact-resistant glass globe, heat- and corrosionproof • Explosionproof design suitable for Zones 1 and 2 (Ex-Gas) and Zones 21 and 22 (Ex-Dust) hazardous areas • Standard U-shape mounting bracket for ceiling and wall mount; pole mount accessories are available (order separately) Reduce operation and maintenance costs Reliable performance in any environment • High quality LED application, shock- and vibration-resistant • T6 temperature rating • Operating ambient -35°C to +50°C (60W-100W models); -35°C to +40°C (125W-150W models) • Warm white color temperature (3300K) is available for special environments, such as fog or smoke • Lead-free and environmentally friendly • Insulation class I • Zones 1 and 2 (Ex-Gas) • Zones 21 and 22 (Ex-Dust) • Marking to 94/9/EC: Ex II 2 GD Ex d e IIC T6 Gb Ex II 2 GD Ex tb IIIC T80°C Db IP66 • EC-type Exam Certification: DNV 11 ATEX 06805X • IECEx - Certificate of Conformity: IECEx-CM 12.0007X • IP66 Standard Materials: 2L • Energy-efficient – 40% reduction in energy used versus equivalent metal halide HID luminaires • 50,000 hours rated life – eliminates need for frequent lamp replacement Certifications and Compliances: • Housing – copper-free aluminum • Globe – tempered and impact-resistant glass, heat- and corrosionproof LED System: • BridgeLux 10W-30W high power LED array • Color temperature: 6000K cool white (standard); 3300K warm white (optional, for special order) • CRI ≥ 65 Electrical Ratings: Model Voltage LPL04-C60-60W LPL04-C60-85W LPL04-C60-100W LPL06-C60-125W LPL06-C60-150W 100-277VAC 100-277VAC 100-277VAC 100-277VAC 100-277VAC 50 50 50 50 50 / / / / / 60 60 60 60 60 Hz Hz Hz Hz Hz Power Factor Input Power > > > > > 60W 85W 100W 125W 150W 0.9 0.9 0.9 0.9 0.9 Specifications: Light Angle Cable Entry Terminal Permissible Ambient Temperature 120° 2 x M25 x 1.5, 1 entry plugged 3 pole, 0.5mm2 to 6mm2 for solid wire -35°C to +50°C -35°C to +40°C www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 60W, 85W, 100W 125W, 150W Copyright© 2013 Eaton’s Crouse-Hinds Business 919 920-921.qxp 12/16/2013 2L 7:40 PM Page 920 Hazard•Gard® LPL Series Explosionproof LED Luminaires Zones 1 & 2 (Ex-Gas) IECEx / ATEX Zones 21 & 22 (Ex-Dust) IP66 Zone 1 high power LED pendant for general illumination Robust construction Variety of mounting options This corrosion-proof fixture offers high quality, shock- and vibration-resistant LEDs, copper-free aluminum housing, and an impact-resistant glass globe. U-shape mounting bracket for ceiling and wall mount is standard. Pole mounting accessories are available and can be purchased separately. 2L Perfect temperature and optical performance for a wide variety of applications With a T-rating of T6, the 60W to 100W models offer a permissible temperature range of -35°C to +50°C, while the 125W and 150W models have an ambient temperature of -35°C to +40°C. Warm white (3300K) color temperature is also available for special environments, such as fog or smoke. Excellent thermal management Provides over 50,000 hours of life under appropriate ambient temperature. Ordering Information - Cool White Color Temperature: Ordering Code Product Type Wattage Color Temperature Ambient Temperature CCL1090001A LPL04-C60-60W 60W 6000K -35°C - +50°C CCL1090002A LPL04-C60-85W 85W 6000K -35°C - +50°C CCL1090003A LPL04-C60-100W 100W 6000K -35°C - +50°C CCL1090004A LPL06-C60-125W 125W 6000K -35°C - +40°C CCL1090005A LPL06-C60-150W 150W 6000K -35°C - +40°C Ordering Information - Warm White Color Temperature: Ordering Code Product Type Wattage Color Temperature Ambient Temperature CCL1090006 LPL04-W33-60W 60W 3300K -35°C - +50°C CCL1090007 LPL04-W33-80W 80W 3300K -35°C - +50°C CCL1090008 LPL04-W33-90W 90W 3300K -35°C - +50°C CCL1090009 LPL06-W33-110W 110W 3300K -35°C - +40°C CCL1090010 LPL06-W33-130W 130W 3300K -35°C - +40°C 920 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 920-921.qxp 12/16/2013 7:40 PM Page 921 Hazard•Gard® LPL Series Explosionproof LED Luminaires Zones 1 & 2 (Ex-Gas) IECEx / ATEX Zones 21 & 22 (Ex-Dust) IP66 2L Zone 1 high power LED pendant for general illumination Dimensions: Weights: R25 R15 230 30˚ 250 230 240.2 Model Kg. LPL04-C60-60W LPL04-C60-85W LPL04-C60-100W LPL06-C60-125W LPL06-C60-150W 17.0 17.0 17.0 17.0 17.0 70 40 45 160 277 Ø302.9 Ø17 2-Ø13 30˚ Wall Mount Ceiling Mount Note: As shown in drawing, U-shape bracket set includes angle locator, to install the bracket horizontally (wall mount) or vertically (ceiling mount) to adjust the aim light to 30˚ past vertical. Pole Mounting Accessories (Order Separately): Ordering Code CCL1076003 Product Type Please refer to below drawing for pole mounting accessories 335.5 60 500 438 20˚ 2L Note: 1. Scope of supply excludes pole mounting accessories, need to purchase separately. 2. As shown in drawing, pole mounting bracket set includes angle locator. To install the bracket vertically, adjust the aim light to 20˚ past vertical. Polar Curve: Standard 6000K, 60WCurve Light Polar LPL04-C60-60W Standard 6000K, 85W Light LPL04-C60-85W -/+180 -150 -150 150 -120 0 90 0 -90 60 900 1500 0 0 -90 90 30 -60 800 -30 150 0 0 -60 60 900 30 Standard 6000K, 125W Light LPL06-C60-125W : cd C0/180 C30/210 C60/240 C90/270 -30 120 0 -60 90 120 0 -90 500 800 1000 60 1600 2000 0 : cd C0/180 C30/210 C60/240 C90/270 150 -120 400 1200 -30 30 -/+180 -150 150 -120 -90 2000 0 Standard 6000K, 150W Light LPL04-C60-150W -/+180 -150 60 1200 1600 120 0 : cd C0/180 C30/210 C60/240 C90/270 90 400 600 1200 -30 120 300 600 150 -120 120 300 -60 -/+180 -150 150 -120 120 -90 Standard 6000K, 100W Light LPL04-C60-100W -/+180 30 : cd C0/180 C30/210 C60/240 C90/270 www.crouse-hinds.com -60 90 60 1500 2000 -30 2500 0 US: 1-866-764-5454 30 : cd C0/180 C30/210 C60/240 C90/270 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 921 922-923.qxp 2L 12/16/2013 7:01 PM Page 922 Cl. I, Div. 2, Groups A, B, C, D NEMA 4X; IP66 Marine and Wet Locations UL Listed CSA Certified LL48 Linear LED Luminaires For heavy industrial applications The LL48 Linear LED Luminaire allows for the replacement of existing harsh and hazardous industrial fluorescent fixtures and provides an energy-efficient proven light source for use in applications where reliability is critical. A Luminaire Model: Model Equivalent Light Output Energy Savings LL48 2 x 58W fluorescent light 50% B Applications: C • Used for general lighting in indoor and outdoor areas with low mounting heights or confined spaces, such as aisles, tunnels and catwalks, over doorways or entries, landing areas, utility rooms, etc. D Certifications and Compliances: NEC Standards: • Class I, Division 2, Groups A, B, C, D • NEMA 4X; IP66 • Marine and Wet Locations UL Standards: • UL844 Electrical Fixture Hangers for Hazardous Locations • UL1598 Luminaire • UL1598A Luminaire for Installation on Marine Vessels CSA Standard: • C22.2 No. 137 Design Features: A Luminaire is designed to match the footprint of a traditional linear fluorescent fixture. B Same light pattern and lumen output at a fraction of the energy cost. C Diffused lens reduces glare. D Shock- and vibration-resistant LEDs contain no mercury, eliminating costly lamp disposal programs. Additional Features and Benefits: Best-in-class reliability Standard Materials: • Linear LED solution can withstand extreme vibration that would cause traditional technologies to fail • Can handle temperature extremes down to -35°C where comparable products cannot operate • Redundant drivers housed next to LED arrays for slim profile and superior heat dissipation • Redundant drivers and LED modules ensure the highest factor of safety in the industry • Housing – copper-free aluminum with Corro-free™ epoxy powder coat end caps and extruded aluminum body • Lens – heat- and impact-resistant glass • External hardware – stainless steel 2L Electrical Ratings: • 100VAC to 277VAC 50 / 60 Hz • Power factor >0.9 Versatile mounting options • Ceiling mount standard (included with fixture) • Choice of brackets for wall or pole mounting (ordered separately); can be mounted in any position to maintain ratings • Luminaire uses the same mounts as eLLK/nLLK Series Reliable performance in any environment • T5 at 40°C, T4A at 55°C temperature ratings • Operating temperature range: -35°C to +55°C Ordering Information: Cat. # System Power Glass Color Entry Lumen Output CCT LL48-60W-765/-F-1M LL48-60W-765/-C-1M LL48-60W-765/-F-1N LL48-60W-765/-C-1N 56W 56W 56W 56W Frosted Clear Frosted Clear M20 M20 1 /2" NPT 1 /2" NPT 3716 4380 3716 4380 Cool Cool Cool Cool 922 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business White, White, White, White, 6500K 6500K 6500K 6500K 922-923.qxp 12/16/2013 7:01 PM Page 923 Cl. I, Div. 2, Groups A, B, C, D NEMA 4X; IP66 Marine and Wet Locations UL Listed CSA Certified LL48 Linear LED Luminaires 2L For heavy industrial applications Dimensions: 67 mm (2.64”) 1036 mm (40.79”) 200 mm (7.87”) Mounting Styles: Ceiling Mount (Included with Fixture) 2L 135° 30° Wall Mount (Order Separately) Pole Mount (Order Separately) Mounting Ordering Information: Cat. # Description 12329778 12329779 12329900 12329901 12329902 12329903 Ceiling Mounting Bracket Kit Clamp for Pole Mounting 11/4" Kit Clamp for Pole Mounting 11/2" Kit Clamp for Pole Mounting 2" Kit Luminaire Wall Suspension 27° Kit Luminaire Wall Suspension 30° Kit Photometrics: • LM79 data available upon request www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 923 924-925.qxp 12/16/2013 2L 7:02 PM Page 924 Champ® VMV LED Series Luminaires Improve safety, reliability and energy efficiency Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL / cUL Listed IECEx / ATEX Simultaneous Presence Wet Locations, Type 4X, IP66 The Champ VMV LED Family VMV LED Series Luminaires are designed to provide full-spectrum, crisp, white light with custom IES Type I, III and V distribution. Five versions of the Champ VMV LED are available, providing ideal solutions for a wide range of applications. Model Nominal† Lumens (Type V) VMV3L VMV5L VMV7L VMV9L VMV11L 3,515 5,288 7,404 9,515 10,935 Wattage Equivalent HID Luminaire Typical Energy Savings / Lifetime 41 67 94 114 118 70W-100W 100W-150W 150W-175W 250W-400W 400W Up Up Up Up Up to to to to to 77% 67% 67% 74% 74% †Tolerance +/- 10%. Applications: • Locations requiring continuous and consistent light levels in extreme ambient temperatures • Areas requiring frequent on-and-off of lights • Where flammable vapors, gases, ignitable dusts, fibers or flyings are present; indoors or outdoors • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist • Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; food and beverage facilities; mining; platforms; loading docks; tunnels; indoor/outdoor spot lighting; outdoor wall and stanchion mounted general area lighting 2L Champ VMV LED Benefits: • Instant illumination and restrike • Better visibility with crisp, white light • Cold temperature operation / no warm-up required • Redundancy in drivers with multiple series circuits connected to each driver to avoid complete loss of illumination • Easy installation – compact modular fixture attaches onto existing Champ mounting module • Energy-efficient technology – up to 77% energy savings over HID fixtures • Provides up to 60,000 hours rated life and up to 170,000 hours of economic life – eliminates need for frequent lamp replacement • Contains no mercury or other hazardous substances • Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break – greatly reduces the risk of premature failure • Operating ambient -40°C to 55°C • Dark sky compliant • 5 year fixture warranty‡ ‡Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. Certifications and Compliances: • DesignLights Consortium® pending for select models* NEC and CEC • Class I, Division 2, Groups A, B, C, D • Class I, Zone 2, nA nR • Class II, Groups E, F, G • Class III • Zone 21 tb • Simultaneous Presence • Wet Locations, Type 4X, IP66 UL Standards • UL844 • UL1598 Luminaires, UL1598A Marine CSA Standard • cUL Listed to CSA Standard CSA C22.2 No. 137 IECEx/ATEX Standards • IEC60079-0:2011/EN60079-0:2012 • IEC60079-15:2010/EN60079-15:2010 • IEC60079-31:2008/EN60079-31:2009 • IEC60529:2001/EN60529:2001 • IEC60598-1:2008/EN60598-1:2008 • IEC60598-2:2008/EN60598-2:2008 • IECEx UL 13.0052X • DEMKO 13 ATEX 1305741X • DEMKO 13 ATEX 1475013X** • CE 100-277 VAC / 108-250 VDC • Ex nA nR IIC T6 Gc -40°C to +40°C • Ex nA nR IIC T5 Gc -40°C to +55°C • Ex tb IIIC T72°C Db IP66 -40°C to +40°C • Ex tb IIIC T87°C Db IP66 -40°C to +55°C • II 3 G Ex nA nR IIC T6 Gc -40°C to +40°C** • II 3 G Ex nA nR IIC T5 Gc -40°C to +55°C** • II 2 D Ex tb IIIC T72°C Db IP66 -40°C to +40°C • II 2 D Ex tb IIIC T87°C Db IP66 -40°C to +55°C 347-480 VAC • Ex nA nR IIC T4 Gc -40°C to +55°C • Ex tb IIIC T70°C Db IP66 -40°C to +40°C • Ex tb IIIC T85°C Db IP66 -40°C to +55°C • II 3 G Ex nA nR IIC T4 Gc -40°C to +55°C** • II 2 D Ex tb IIIC T70°C Db IP66 -40°C to +40°C • II 2 D Ex tb IIIC T85°C Db IP66 -40°C to +55°C *Cool white 120-277 VAC 3L-11L models. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. 924 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Standard Materials: • Lamp housing and adapter – die cast aluminum with Corro-free™ epoxy powder coat • Lens – heat- and impact-resistant glass • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required LED System: • High intensity discrete power emitters • Cool white (5000K, 70 CRI) and warm white (3000K, 80 CRI) • Custom optics designed to go over each discrete LED Custom Optics: Three optical options to maximize light distribution and intensity: TYPE I Ideal for: • Mining conveyor belts • Aisleways and hallways • Catwalks and walkways • Ramps and loading docks • Tunnels with overhead mounts TYPE III Ideal for: • Narrow crosswalks or passages with wall mounted fixtures • Tunnels with wall mount • Wall or stanchion mount requiring 180° forward throw beam patterns TYPE V Ideal for: • Pendant, ceiling or stanchion mount overhead building mounts • Processing mills, industrial plants, large buildings, warehouses, etc. Copyright© 2013 Eaton’s Crouse-Hinds Business 924-925.qxp 12/16/2013 7:03 PM Page 925 Champ® VMV LED Series Luminaires Improve safety, reliability and energy efficiency Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL / cUL Listed IECEx / ATEX Simultaneous Presence Wet Locations, Type 4X, IP66 2L Drivers: Option 3L - 11L /UNV1 /UNV34** /VDC‡ 120-277 VAC, 50 / 60 Hz 347-480 VAC, 50 / 60 Hz 108-250 VDC, 50 / 60 Hz **No separate external transformer required to step down voltage. ‡Separate driver for DC applications. Electrical Ratings: VMV3L VMV5L VMV7L VMV9L VMV11L Voltage Range, VAC 120-277 120-277 120-277 120-277 120-277 Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Input Power (Watts) 41 67 94 114 118 Input Amps at 120-277 VAC 0.34-0.17 0.57-0.29 0.80-0.42 0.96-0.49 0.96-0.49 Voltage Range, VDC 108-250 108-250 108-250 108-250 108-250 Power Factor >0.90 >0.90 >0.90 >0.90 >0.90 Nominal Lumens† (Type V) 3,515 5,288 7,404 9,515 10,935 †Tolerance +/- 10%. Design Features: A A Installation and replacement made simple - this contractor-friendly, E B C D 2L modular design is ideal for both retrofit and new construction applications. These luminaires are installed in the same manner and use the same mounting modules as existing Champ® Series luminaires. The compact modular design of the VMVL allows for easy component replacement and future upgrade. B High efficiency and lumen output - custom high efficiency LED drivers are designed to provide reliable operation in even the harshest environments. Various AC and DC input voltage options are available to suit virtually any drive requirement. C Safe, reliable heat transfer - die cast aluminum housing provides safe and effective heat transfer from the LED assembly to the outside environment, ensuring low LED junction temperature, reliability, and sustained lumen performance. The vertical fin design facilitates air flow and dust shedding. The impact-resistant lens is sealed from the outside environment and provides ingress protection against water and dust. D Custom optics - custom optics designed for discrete LED power emitters. E Ease of wiring and installation - available with lever lock connectors and standard three-pole terminal block for ease of wiring and installation. Custom Optics: Custom optics designed for discrete LED power emitters: • Type V standard • Type I and Type III optional Type I Type III Type V Colored LED Options: • • • • Available in red, blue, green and amber Reduction in light pollution for night space observation and sky glow due to isolating blue wavelength in red and amber colors Wildlife friendly Improves visibility for telescopes in observatories during night sky space exploration www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 925 926-927.qxp 12/16/2013 2L 7:03 PM Page 926 Champ® VMV LED Series Luminaires Improve safety, reliability and energy efficiency Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL / cUL Listed IECEx / ATEX Simultaneous Presence Wet Locations, Type 4X, IP66 Catalog Numbering System: VMV 7L W 2A R1 G /UNV1 S890 Lamp/Function 3L 3,515 Lumen LED 5L 5,288 Lumen LED 7L 7,404 Lumen LED 9L 9,519 Lumen LED 11L 10,935 Lumen LED RL Red (3,200 Lumen) /UNV1 GL Green (4,300 Lumen) BL Blue (2,100 Lumen) AL Amber (5,000 Lumen) Color Temperature BLANK W Suffixes Guard Cool BLANK No Guard S812 Trunnion Mount Kit with Pin (5000 ± 200K) G P3001 Wire Guard S890 Quick Clip S891 Diffused Lens† S896 Teflon Coated Lens† 120-277 VAC, 50/60 Hz S903 Polycarbonate Lens /UNV34 347-480 VAC, 50/60 Hz TB6 Six-pole Terminal Block† /VDC 108-250 VDC, 50/60 Hz Warm Voltage (3000K ± 200K) Mounting Style BLANK No Cover J 1-½” Stanchion 25° P 1-½” Stanchion Straight 2A 3A 2B 3B 2C 3C 2HA Optics ¾” Pendant 1” Pendant ¾” Cone Pendant 1” Cone Pendant ¾” Ceiling 1” Ceiling ¾” Flexible Pendant 2TW ¾” Wall 3TW 1” Wall BLANK Type V Optic Standard (All Mounts) R1 Type I Optic (All Mounts Minus Ceiling) R1A Type I Optic (Ceiling with Conduit 45° Counterclockwise or 135° Clockwise from Hinge)* R1B Type I Optic (Ceiling with Conduit 45° Clockwise or 135° Counterclockwise from Hinge)* R3 Type III Optic (All Mounts Minus Ceiling) R3A1 Type III Optic (Ceiling with Conduit 45° Counterclockwise from Top Hat Hinge)** R3A2 Type III Optic (Ceiling with Conduit 135° Clockwise from Top Hat Hinge)** R3B1 Type III Optic (Ceiling with Conduit 45° Clockwise from Top Hat Hinge)** R3B2 Type III Optic (Ceiling with Conduit 135° Counterclockwise from Top Hat Hinge)** 2L *For new construction, order R1A only. **For new construction, order R3A1 only. †Not available for IEC applications. Options: Description Wire guard with captive mounting hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trunnion mount with redundant pin locking mechanism (ceiling mount required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Clip for quick installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diffused lens for glare reduction‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Teflon coating on lens for additional shatter protection‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polycarbonate lens available in applications where glass is prohibited . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-pole terminal block‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Suffix P3001 S812 K1 S890 S891 S896 S903 TB6 ‡‡Not available for IEC applications. Accessories (Ordered Separately): Description Photocell, 120V, 50 / 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Photocell, 208-277V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Occupancy sensor, 1/ 2" entry, 120 / 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Occupancy sensor, 3/ 4" entry, 120 / 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Occupancy sensor, 1" entry, 120 / 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ***For 347-480 VAC, replace /UNV1 with /UNV34. 926 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Cat. # (Ordered Separately) D2S20 D2S208 277 COS1/UNV1 COS2/UNV1 COS3/UNV1 926-927.qxp 12/16/2013 7:03 PM Page 927 UL / cUL Listed IECEx / ATEX Simultaneous Presence Wet Locations, Type 4X, IP66 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III Champ® VMV LED Series Luminaires Improve safety, reliability and energy efficiency 2L Dimensions: Pendant Ceiling Wall Trunnion 273.5 10.77 2X LOCKING PINS 118.6 4.67 354.6 13.96 50.8 2.00 295.2 11.62 BRACKET FOR WALL MOUNT OR SFA6 SLIPFITTER 258.6 10.18 295.1 11.62 Cone Pendant 300.4 11.83 71.2 2.80 2X TRUNNION ROTATION HARDWARE 117.5 4.63 51.6 2.03 158 6.22 CM2 OR CM3 TOP HAT 279.4 11.00 287.3 11.31 386.6 15.22 280.1 11.03 225.6 8.88 Stanchion Angled 2X TOP HAT MOUNTING HARDWARE Stanchion Straight 407.2 16.03 Weights: 88.7 3.49 382.7 15.07 53.4 2.10 273.8 45.2 10.78 1.78 326.3 12.85 282 11.10 25° 247.7 9.75 Net Luminaire Weight: 21.8 lbs. 8.07 kg. Mounting Module add (lb.) Pendant Cone Pendant Flexible Pendant Ceiling Wall Angle Stanchion Straight Stanchion 1.25 4.00 1.50 2.75 4.50 3.50 4.50 0.57 1.81 0.68 1.25 2.04 1.59 2.04 Temperature Codes: 3L, 5L, 7L, 9L, 11L‡ Driver Type Ambient Cl. II, Div. 1 Sim. Pres. / Cl. I, Div. 2 / Cl. II, Div. 1 /UNV1 (100-277 VAC) 40°C T6 T5 T3C T72 /VDC (108-250 VDC) 55°C 40°C 55°C 40°C T5 T4 T4 T5 T4A T5 T4A T6 T3B T3C T3A T4A T87 T70 T85 T60 55°C T4 T6 T4A T75 /UNV34 (347-480 VAC) RL, GL, BL, AL /UNV1 (100-277 VAC) Zone 21 2L Model Cl. I, Div. 2 / Zone 2, nA, nR ‡Teflon and diffused glass options are only NEC certified for: Class I, Division 2/Sim. Pres. - T3C (40°C); T3B (55°C) for /UNV1 and /VDC, and T3C (40°C); T3A (55°C) for /UNV34. Class II, Division 1 - T5 (40°C); T4A (55°C) for /UNV1, /VDC and /UNV34. Family Tree: MOUNTING MODULE SERIES PENDANT APM2 APM3 HPM2 ANGLED BPM2 BPM3 CEILING CM2 CM3 WALL TWM2 TWM3 STANCHION PM5 JM5 VMV*L PVM*L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 927 928-929.qxp 12/16/2013 7:04 PM Page 928 UL / cUL Listed IECEx / ATEX Simultaneous Presence Wet Locations, Type 4X, IP66 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III Champ® VMV LED Series Luminaires 2L Improve safety, reliability and energy efficiency Photometric Data: Photometric Layout Comparison - Champ® VMV7L LED Versus 175W Metal Halide: VMV7L - Type I VMV 175W PSMH - Type I 50 50 40 30 20 10 0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.6 0.6 0.6 0.7 0.7 0.6 0.6 0.6 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.7 1.0 1.1 1.1 1.4 1.4 1.1 1.1 1.0 0.7 0.5 0.3 0.2 0.2 0.1 0.2 0.3 0.4 0.5 0.6 0.9 1.1 1.3 2.1 2.6 2.6 2.1 1.3 1.1 0.9 0.6 0.5 0.4 0.3 0.2 0.4 .5 0.5 0.7 1.0 1.5 2.0 2.1 2.1 3.0 2.9 2.9 3.0 2.1 2.1 2.0 1.5 1.0 0.7 0.5 0.4 1.75 40 30 20 10 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.3 0.4 0.4 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.5 0.4 0.3 0.3 0.2 0.2 0.3 0.5 0.6 0.8 1.0 1.0 0.6 0.8 0.7 0.7 0.8 0.7 1.0 1.0 0.8 0.7 0.5 0.4 0.3 0.3 0.5 0.7 0.9 1.2 1.7 2.4 2.7 3.0 3.2 3.3 3.0 2.7 2.4 1.8 1.3 1.0 0.7 0.5 0.4 0.4.5 0.6 0.9 1.2 1.75 1.7 2.4 3.5 4.8 6.3 7.3 7.2 6.3 4.7 3.4 2.5 1.7 1.3 0.9 0.7 0.5 -20 -30 -40 -50 0.4 .5 0.5 .75 0.7 11.0 1.5 1.5 22.0 2.1 2.1 2.9 2.6 2.6 2.9 2.1 2.1 2.0 1.5 1.0 0.7 0.5 0.4 0.2 0.3 0.4 0.5 0.6 0.9 1.1 1.2 1.9 2.4 2.4 1.9 1.2 1.1 0.9 0.6 0.5 0.4 0.3 0.2 0.1 0.2 0.2 0.3 0.5 0.7 1.0 1.1 1.0 1.3 1.3 1.0 1.1 1.0 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 -10 -20 -30 -40 -50 0.4.5 0.6 0.3 0.5 .75 0.9 1 1.2 0.7 0.9 1.5 1.7 2 2.4 1.2 1.7 3 3.5 4 5 4.8 2.4 2.7 -40 -30 -20 -10 0 6 7 6.3 3.0 7.3 7.2 6.3 4.7 3.4 2.5 1.7 1.3 0.9 0.7 0.5 3.2 3.3 3.0 2.7 2.4 1.8 1.3 1.0 0.7 0.5 0.4 0.2 0.3 0.5 0.6 0.8 1.0 1.0 0.6 0.8 0.7 0.7 0.8 0.7 1.0 1.0 0.8 0.7 0.5 0.4 0.3 0.2 0.2 0.3 0.4 0.4 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.5 0.4 0.3 0.3 0.2 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Point By Point Foot-Candles -50 0.25 7L Type I VMVM2C175G241-S828 -10 TYPE I OPTICAL PATTERN 20 30 40 50 -50 -40 -30 -20 -10 0 10 20 30 40 1 1.25 1.5 2 4 3 5 6 7 Calculation Summary Point By Point Foot-Candles 10 Distance In Feet 0.75 Label Calc. Type (in Fc) Avg. Max. Min. VMV 175W MH Grid Illuminance 0.49 3.0 0.0 VMV LED Grid Illuminance 0.58 7.3 0.0 50 Distance In Feet VMV7L - Type III VMV 175W PSMH - Type III 50 50 40 30 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.4 0.4 0.4 0.4 20 0.5 0.6 0.4 0.5 0.6 0.5 0.4 0.6 0.8 1.0 1.1 1.2 1.1 0.7 0.8 0.8 0.9 0.9 0.8 0.8 0.7 1.1 1.2 1.1 1.0 0.8 0.6 10 0.5 0.7 11.0 1.5 1.9 2.1 1.8 1.2 1.1 1.1 1.1 1.1 1.2 1.8 2.1 1.9 1.5 1.0 0.7 0.5 0.7 0.7 2.5 0.5 0.8 1.2 1.72 2.6 .25 0.2 0.3 0.5 0.7 1.0 1.5 2.0 2.0 0.2 0.2 0.3 0.4 0.6 0.9 1.3 1.6 0.2 0.2 0.3 0.4 0.5 0.8 1.0 0.1 0.2 0.3 0.4 0.5 0.7 0.1 0.2 0.2 0.3 0.4 0.6 0.1 0.2 0.2 0.3 0.3 0.4 0.1 0.1 0.2 0.2 0.3 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.4 0 0.6 .5 1.5 0.6 0.7 0.7 0.6 0.6 0.6 0.7 0.7 0.6 2.4 3.3 2.9 2.6 1.7 1.2 0.8 0.5 0.4 3.7 2.0 2.0 1.5 1.0 0.7 0.5 0.3 0.2 3.8 2.8 2.8 3.8 1.6 1.3 0.9 0.6 0.4 0.3 0.2 0.2 1.2 1.5 2.9 2.9 1.5 1.2 1.0 0.8 0.5 0.4 0.3 0.2 0.2 0.9 1.0 1.1 1.2 1.2 1.1 1.0 0.9 0.7 0.5 0.4 0.3 0.2 0.1 0.7 0.9 0.9 0.9 0.9 0.9 0.9 0.7 0.6 0.4 0.3 0.2 0.2 0.1 0.5 0.6 0.7 0.7 0.7 0.7 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.3 0.4 0.4 0.4 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 2.0 4 3.3 2.4 3.7 4.5 2.0 30 0.5 4.5 2.9 40 20 10 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.6 0.6 0.6 0.5 0.4 0.3 0.2 0.2 0.2 0.1 0.1 1.1 1.2 1.2 0.7 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.9 0.2 0.2 0.3 0.4 0.5 0.7 1.1 1.5 2.0 2.4 0.2 0.2 0.3 0.5 0.7 1.0 1.6 2.6 3.5 4.3 0.2 0 0.3 0.4 0.2 0.3 0.4 0.2 .25 0.3 0.4 -10 0.2 0.2 -20 0.1 0.1 0.1 -30 -40 -50 -40 -30 -20 -10 0 0.4 0.3 0.2 1.5 1.1 0.7 0.5 0.4 0.3 0.2 0.2 2.6 1.6 1.0 0.7 0.5 0.3 0.2 0.2 6.4 7.6 0.5 0.2 0.1 5.4 3.5 7.6 6.2 3.9 2.3 1.4 0.9 0.6 0.4 0.3 0.2 4.6 5.9 5.9 4.6 2.9 1.8 1.2 0.8 0.5 0.4 0.3 0.2 1.0 1.4 2.2 4.0 4.0 2.2 1.4 1.0 0.8 0.6 0.4 0.3 0.2 0.2 0.4 0.5 0.5 0.9 1.3 1.3 0.9 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.2 0.2 0.3 0.5 0.6 0.6 0.5 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.8 1.3 0.3 0.4 0.6 0.8 0.2 0.2 0.3 0.4 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2.1 1.4 2 1.2 1.5 3.5 2.3 3 3.9 5 6 6.4 2.1 1.3 0.8 0.5 0.4 0.3 0.2 0.25 coo173140 -10 -20 -30 -40 -50 .5 1 1.8 2.5 Point By Point Foot-Candles -50 0.9 2.0 3.5 6.2 0.8 0.9 0.5 VMVM2C175G243-S828 3 1.1 2.4 4.3 2.9 0.5 0.6 5.4 4 TYPE III OPTICAL PATTERN 20 30 40 50 -50 -40 -30 -20 -10 10 20 30 40 1.5 2.5 2 4 3 5 6 Label Calc. Type (in Fc) Avg. Max. Min. VMV 175W MH Grid Illuminance 0.59 4.5 0.1 VMV LED Grid Illuminance 0.61 7.6 0.0 50 Distance In Feet 2L Distance In Feet 0 1 Calculation Summary Point By Point Foot-Candles 10 0.5 VMV 175W PSMH - Type V VMV7L - Type V 50 50 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.5 0.6 0.7 0.7 0.7 0.7 0.6 0.5 0.3 0.3 0.2 0.2 0.1 0.1 20 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.8 0.9 1.0 1.0 0.9 0.8 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.9 1.1 1.2 1.3 1.3 1.2 10 0.1 0.2 0.2 0.4 0.6 0.8 1.1 1.3 1.4 1.7 1.7 1.4 1.3 1.1 0.8 0.6 0.4 0.2 0.2 0.1 0.1 0.2 0.3 0.4 0.7 0.9 1.2 1.4 2.2 2.8 2.8 2.2 1.4 1.2 0.9 0.7 0.4 0.3 0.2 0.1 2.8 2.6 2.6 2.8 1.7 1.3 1.0 0.7 0.5 0.3 0.2 0.1 2.8 2.6 2.6 2.8 1.7 1.3 1.0 0.7 0.5 0.3 0.2 0.1 2.2 2.8 2.8 2.2 1.4 1.2 0.9 0.7 0.4 0.3 0.2 0.1 40 30 0 0.1 0.2 0.3 0.5 0.7 1.0 1.3 0.1 0.2 0.3 0.5 0.7 11.0 1.3 -10 0.1 0.2 0.3 0.4 0.7 0.9 1.2 1.1 1.75 1.7 1.1 0.9 0.7 0.5 0.3 0.2 0.2 40 30 20 0.1 10 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.8 1.1 1.1 0.9 0.6 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 1.3 2.1 2.6 2.6 2.3 1.5 0.8 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 1.3 2.6 3.9 4.9 4.9 4.1 2.8 1.6 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.8 2.0 3.9 5.8 7.2 7.2 6.1 4.2 2.3 1.0 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 7 7.1 6.5 5 5.1 2.8 1.3 0.4 0.1 0.0 0.0 0.0 7.1 6.5 6.4 7.3 5.1 2.8 1.3 0.4 0.1 0.0 0.0 0.0 5.8 7.2 7.2 6.1 4.2 2.3 1.0 0.3 0.1 0.0 0.0 0.0 1.6 0.6 0.2 0.1 0.0 0.0 0.3 .75 1.0 1.75 2.5 4.8 -20 -30 -40 -50 1.7 1.4 2 0.1 0.2 0.2 0.4 0.6 .75 0.8 1.3 1.4 1.7 1.7 1.4 1.3 1.1 0.8 0.6 0.4 0.2 0.2 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.9 1.1 1.2 1.3 1.3 1.2 1.1 0.9 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.8 0.9 1.0 1.0 0.9 0.8 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.5 0.6 0.7 0.7 0.7 0.7 0.6 0.5 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 .5 1 1.0 2 2.5 0.8 1.5 2.0 -40 -30 -20 -10 0 10 4 7.3 0.0 0.0 0.0 0.1 0.3 -10 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.0 0.1 0.1 0.4 1.3 2.6 -20 0.0 0.0 0.0 0.0 0.1 0.2 0.6 1.3 2.1 2.6 2.6 2.3 1.5 0.8 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.8 1.1 1.1 0.9 0.6 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 -30 -40 -50 .5 Point By Point Foot-Candles -50 6.4 0.5 7L Type V VMVM2C175G245-S828 1.5 TYPE V OPTICAL PATTERN 3 4.8 3.9 6 3.9 4.9 4.9 4.1 2.8 30 40 50 -50 -40 -30 -20 -10 0 10 20 30 40 1 1.5 1.75 3L 5L 7L 9L 11L Type I 3,115 4,687 6,562 8,437 9,692 Type III 3,271 4,921 6,890 8,859 10,177 Type V 3,515 5,288 7,404 9,519 10,935 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 4 5 6 Calc. Type (in Fc) Avg. Max. Min. VMV 175W MH Grid Illuminance 0.51 2.8 0.1 VMV LED Grid Illuminance 0.69 7.3 0.0 50 †Tolerance +/- 10%. 928 3 Label Distance In Feet Actual Lumens (Nominal†) 2 Calculation Summary 0.0 Point By Point Foot-Candles 20 Distance In Feet 0.75 Copyright© 2013 Eaton’s Crouse-Hinds Business 7 928-929.qxp 12/16/2013 7:04 PM Page 929 Champ® FMV LED Series Floodlight Fixtures Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III FMV LED Series Floodlights are designed to provide full-spectrum, crisp, white light. Five versions of the Champ FMV LED are available, providing ideal solutions for a wide range of applications. Equivalent MH HID Lamp Energy Savings FMV FMV FMV FMV FMV 100W-150W 150W-175W 175W-250W 250W-400W 400W Up to 62%! 5L 7L 9L 11L 13L Reduce operation and maintenance costs • Easy installation - compact modular fixture attaches onto existing SFA6 and SWB6 • Energy-efficient technology – use up to 1/ 2 the power of standard HID luminaires • Provides up to 60,000 hours rated life – eliminates need for frequent lamp replacement • Contains no mercury or other hazardous substances Reliable performance in any environment Applications: • Five lumen outputs allow for installation in numerous mounting heights • Locations requiring continuous and consistent light levels in extreme ambient temperatures • Areas requiring frequent on-and-off of lights • Where flammable vapors, gases, ignitable dusts, fibers or flyings are present; indoors or outdoors • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist • Type 4X, marine, wet locations, and hose-down environments • Indoor and outdoor area lighting in plants, buildings, and parking areas • Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; platforms; loading docks; outdoor mounted general area lighting Option 1 Option 2 5L - 13L 90-305 VAC, 50 / 60 Hz; 108-250 VDC 347 VAC Model 480 VAC Model Champ FMV LED Benefits: Enhance safety and productivity • Instant illumination and restrike • Better visibility with crisp, white light • Minimum T4 temperature rating – safely operate in the most hazardous environments and any non-hazardous location • Cold temperature operation / no warm-up required Electrical Ratings: • Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break – greatly reduces the risk of premature failure • Operating ambient -40°C to 55°C • Dark sky friendly with optional visor Certifications and Compliances: • DesignLights Consortium® approved for select models (refer to Ordering Information for details) NEC and CEC • Class I, Division 2, Groups A, B, C, D • Class I, Zone 2 • Class II, Groups E, F, G • Class III • Simultaneous Presence • Wet Locations, Type 4X, IP66 UL Standards • UL844 • UL1598 Luminaires, UL1598A Marine CSA Standard • CSA C22.2 No. 137 IECEx/ATEX • IECEx UL 11.0054X • Ex nA nR IIC T4 Gc Tamb -30°C to +55°C • Ex nA nR IIC T5 Gc Tamb -30°C to +40°C • Ex tc IIIC T68°C Dc IP66 Tamb -30°C to 40°C • DEMKO 12 ATEX 115535X • Ex II 3 G Ex nA nR IIC T4 Gc Tamb -30°C to +55°C • Ex II 3 G Ex nA nR IIC T5 Gc Tamb -30°C to +40°C • Ex II 3 D Ex tc IIIC T68°C Dc IP66 Tamb -30°C to +40°C • CEPEL Ex-1956/10 FMV 5L FMV 7L FMV 9L Standard Materials: • Housing – copper-free aluminum with Corro-free™ epoxy powder coat • Lens – shatter-resistant glass • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required LED System: • High brightness light emitting diode (LED) arrays • Color temperature: 3000K (CRI 82) and 5600K (CRI 65) options available • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions • LM-80 reports available upon request Options: Description Suffix Fused (only applies to UNV1 model, not available for 347V or 480V; NOT marine or cUL Listed) (NEC version only) . . . . . . . . . . . S658 Two conduit/cable glands of like thread installed . . . . . . . . . . S886 Accessories (Order Separately): Description Bolt-on visor (sold separately) . . . . . . . . . . . . Bolt-on wire guard (sold separately) . . . . . . . . . . . . Floodlight slipfitter (sold separately) . . . . . . . . . . . . Slipfitter wall mount adapter (sold separately) . . . . . . . . . . . . FMV 11L Cat. No. DSV1 P61 SFA6 SWB6 FMV 13L 100-277V 50 / 60 Hz Voltage Range, VAC 347 / 480V 60 Hz Voltage Range, VDC 108-250 108-250 108-250 108-250 108-250 Input Power (Nom.) 64 89 121 149 179 Input Amps (Max.) 0.550 0.800 1.083 1.608 1.608 Power Factor >0.85 >0.85 >0.85 >0.85 >0.85 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 929 2L Drivers: Model Standard 2L • “No lights out” feature – if a single LED fails, others will remain lit from other drivers – minimum 50% output maintained • Terminals – 3 x 6 sq. mm. for IEC version The Champ FMV LED Family FMV Model UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 930-931.qxp 2L 12/16/2013 7:40 PM Page 930 Champ® FMV LED Series Floodlight Fixtures Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 Safe, reliable heat transfer Installation and replacement made simple The heat sink was designed to perform in high ambient temperatures up to +55ºC and as low as -40ºC. The thick walls of the castings make for a tough, rugged housing that keeps the internal driver and LED temperatures down, allowing them to perform flawlessly, and protects them from damage. Separated driver and LED housing allows dust to shed from fixture. The full-frame yoke was designed to utilize the SFA6 slipfitter and SWB6 wall mount bracket (sold separately), making it ideal for retrofit or new installations. The modular design of the FMV LED allows for easy driver or LED replacement, and allows for the addition of the optional visor or guard in the field. Single cable gland provided with a second plugged cable entry, if an additional cable gland is needed. High efficiency and lumen output 2L High efficiency drivers and LED arrays provide reliable low cost operation in harsh and hazardous environments. Components were chosen to give industry-leading light output from an LED flood. Replaceable drivers and LEDs for ease of maintenance and “no lights out” feature. Versatile design Suitable for hazardous location use in gas or dust areas. Can be used for outdoor or indoor applications, and for a wide range of mounting heights depending on model and light level requirement. Optics were specifically designed to give the familiar and industry-accepted butterfly beam light pattern. 930 www.crouse-hinds.com US: 1-866-764-5454 Optional equipment Cool (C) and Warm (W) white color temperatures available. Optional visor offered (sold separately) to control light spill. Optional wire guard offered (sold separately) to protect lens from damage. Other options available - consult part numbering guide. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 930-931.qxp 12/16/2013 7:40 PM Page 931 Champ® FMV LED Series Floodlight Fixtures Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 2L Catalog Numbering System: SERIES LIGHT SOURCE COLOR MOUNT VOLTAGE OPTICAL DISTRIBUTION SUFFIXES FMV 9L C Y /UNV1 76 S658 SERIES FMV NFMV NEC version with Class/Division ratings IEC version with Class/Zone ratings LIGHT SOURCE / INTENSITY 5L 7L 9L 11L 13L 100W - 150W equivalent 150W - 175W equivalent 175W - 250W equivalent 250W - 400W equivalent 400W equivalent COLOR TEMPERATURE C W 5600K (cool white) 3000K (warm white) MOUNT Y Yoke VOLTAGE /UNV1 /120 /347 /480 100 VAC to 277 VAC 50/60 Hz, 108 VDC to 250 VDC 120 VAC 50/60 Hz** 347 VAC 60 Hz 480 VAC 60 Hz OPTICAL DISTRIBUTION 76 Floodlight pattern optics included ADDITIONAL ITEMS (SOLD SEPARATELY) SUFFIXES 20mm metric threads for conduit opening (NFMV only)* 25mm metric threads for conduit opening (NFMV only)* Fused; for UNV1 only; not for marine or cUL Two conduit/cable glands of like thread installed DSV dark sky visor Wire guard factory installed Floodlight slipfitter Slipfitter wall mount adapter 2L M20 M25 S658 S886 DSV1 P61 SFA6 SWB6 *Required for NFMV. Please specify conduit entry. **5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton’s Crouse-Hinds standard Terms and Conditions. DesignLights Consortium® approved models. Cool white only. Dimensions: [532.9] 21.0 [167.1] 6.6 [552.5] 21.75 [405.9] 16.0 [120.7] 4.75 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 [14] Ø.55 Copyright© 2013 Eaton’s Crouse-Hinds Business 931 932-933.qxp 12/16/2013 7:05 PM Page 932 Champ® FMV LED Series Floodlight Fixtures 2L Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 Photometric Data: FMV 13L @ 40 Ft. High; Tilt Angle = 45 Degrees (Isofootcandles) Point By Point FC Readings Distance in Feet .35 Fc .5 Fc 1 Fc 2 Fc 2.5 Fc MULTIPLIERS FOR OTHER LED FLOODLIGHTS Luminaire Series Wattage Lumens* FMV 5L 64 4386 FMV 7L 89 6720 FMV 9L 121 8478 FMV 11L 149 10420 2L *FMV 13L output is 12,940. Weights: Model Lbs. Kg. 5L 7L 9L 11L 13L 39.11 39.16 39.73 40.35 40.35 17.74 17.76 18.02 18.30 18.30 Ambient Temperature: Max. Temp. ºC FMV 5L FMV 7L FMV 9L FMV 11L FMV 13L 932 Cl. I, Div. 2 Cl. I, Zone 2 Simu. Presence Div. 1 and Div. 2 Cl. II, Div. 1 Cl. III 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 932-933.qxp 12/16/2013 7:05 PM Page 933 Vaporgard™ LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups F, G IECEx/ATEX The Vaporgard LED Family: V2LC/UNV - Cool White Color Temperature The V2LC/UNV Luminaire provides uniform crisp, white light and is suitable for lower mounting heights, confined spaces, tunnels, or utility rooms. Using four high power, high brightness LED arrays, this fixture can deliver similar light levels to 150 watt incandescent. V2LW/UNV - Warm White Color Temperature The V2LW/UNV Luminaire provides similar benefits as the cool white version, but with a color rendering more consistent with a warm incandescent or HPS lamp source. Perfect for situations where Vaporgard LED will be installed next to a warmer color light source. DC Power Supply - Available for Applications Requiring DC Power For applications with DC power requirements such as solar or back-up battery. The DC power supply is suitable for 12VDC through 24VDC. Applications: Vaporgard LED Luminaires are ideal for use in: • Wet, dirty, dusty, corrosive, hot/cold conditions • Hazardous locations • Confined space or low ceiling areas, such as tunnels, utility rooms, over doorways or entries, top of landings, etc. • Areas requiring frequent on/off of lights • Areas where maintenance is difficult or challenging • Areas requiring shatter-protected products, such as food processing facilities • Outdoor wall or ceiling mounted area illumination • Low mounting heights Vaporgard LED Benefits: Enhance safety and productivity Instant illumination and restrike Cold temperature operation; no warm-up time Multi-die LED arrays improve reliability Lightweight, low profile, and cool surface temperatures Driver with internal fusing for branch circuit protection 22 watt LED system can save up to 85% in energy costs 50K hours rated life can provide >10 years of maintenance-free lighting No mercury or hazardous chemicals - eliminates disposal concerns Mounts to existing Vaporgard mounting modules Reliable performance in any environment • Shock- and vibration-resistant • Teflon coated lens (suffix S896) option for increased safety in food processing facilities • Low starting temperature: -30°C • Operating ambient: -30°C to 55°C (High Temperature Option) • Dark sky compliant • Body and mounting modules – copper-free aluminum with Corro-free™ epoxy powder coat • Lens bezel – aluminum with anodized finish • Lens – heat- and impact-resistant glass • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required LED System: • • • • • • (4) High brightness LED arrays Cool white (5600K), CRI 65 Warm white (3000K), CRI 82 70% lumen maintenance (L70) at 50K hours Junction temperature Tj <90°C ensures long life Array complies with requirements of IEC LM80 LED Drivers: • • • • • • • • Constant current regulated power supply 90VAC - 264VAC, 277VAC, 50/60Hz Internal fusing Active power factor correction, >0.9 Low harmonic distortion, <20% Low inrush current, <20 amps EMC compliant to 47CFR, Part 2, Part 15 12VDC/24VDC option available Description Suffix Frosted lens reduces glare in applications where the user may have direct visual contact with the light source (NEC version only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S891 Teflon coating on lens provides additional shatter protection for applications in food and beverage facilities (NEC version only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S896 High temperature option allows operation up to 55°C ambient temperature (AC unit only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . S902 BR Brazil (CEPEL) certification (IEC version only) . . . . . . . . . . . . . Electrical Ratings: Series V2LC/UNV1* V2LW/UNV1 V2LC/DC1 V2LW/DC1 90-264VAC, 90-264VAC, 12-24VDC 12-24VDC 277VAC 277VAC Input Power (Watts) 22 22 22 22 Voltage Certifications and Compliances: • RoHS Compliant • DesignLights Consortium® approved for select models (refer to Ordering Information for details) NEC and CEC • Class I, Division 2, Groups A, B, C, D • Class II, Division 1, Groups F, G • NEMA 4X UL Standards • IP66 • UL844 www.crouse-hinds.com Standard Materials: Options: Reduce operation and maintenance costs • • • • • UL1598A Marine • UL1598 Wet Locations CSA Standard • CSA C22.2 No. 137 IECEx/ATEX • Ex II 3 G Ex nA IIC T4 Gc (T4 at 55°C) • Ex II 3 D Ex tc IIIB T69°C Dc IP66 • EN60079-0:2009, EN60079-15:2010, EN60079-31:2009 US: 1-866-764-5454 Input Current 0.23 / 0.10 0.23 / 0.10 2.1 / 1.0 Power Factor >0.9 >0.9 N/A 2.1 / 1.0 N/A THD (I) (%) <20% <20% N/A N/A Maintained Lumens 1633 1400 1633 1400 Efficacy, LPW 64 56 64 56 Color Temperature 5600K 3000K 5600K 3000K *5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium approved models. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 933 2L • • • • • 2L UL Listed & CSA Certified Wet Location NEMA 4X IP66 934-935.qxp 12/16/2013 7:07 PM Page 934 Vaporgard™ LED Series Luminaires 2L Leading the way in LED technology for industrial and hazardous applications Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups F, G IECEx/ATEX UL Listed & CSA Certified Wet Location NEMA 4X IP66 Installation and replacement made simple Safe, reliable heat transfer This contractor-friendly design is ideal for both retrofit and new construction applications. These luminaires are installed using the same wall and ceiling mounting modules as existing Vaporgard fixtures. Heat sink - engineered to safely and effectively remove heat from the LED and the driver, while providing durable protection for the optical elements of the fixture. This unique design increases overall flexibility of the luminaire by reducing both driver temperature and junction temperature of the LED arrays. Easy Maintenance and Component Replacement The compact and modular design of the Vaporgard LED allows for both easy component replacement and future upgrade. Unique domeless, low profile design 2L Unique domeless, low profile design for low mounting heights and confined spaces where incandescent and HID based luminaires are too large to fit the mechanical envelope required. LED Arrays Four high power multi-die LED arrays provide instant on and full illumination throughout specified operational temperature range. Since LEDs contain no filament or lamp, the fixture can survive even the harshest environmental conditions and exposure to high, repeated vibration. 934 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 934-935.qxp 12/16/2013 7:07 PM Page 935 UL Listed & CSA Certified Wet Location NEMA 4X IP66 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups F, G IECEx/ATEX Vaporgard™ LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications 2L Ordering Information - NEC and CEC: Cool White Warm White Mounting Style AC Drive DC Drive AC Drive DC Drive /2” Pendant* V2LCA1/UNV1*** V2LCA1/DC1 V2LWA1/UNV1 V2LWA1/DC1 1 3 /4” Pendant* V2LCA2/UNV1*** V2LCA2/DC1 V2LWA2/UNV1 V2LWA2/DC1 1” Pendant* V2LCA3/UNV1*** V2LCA3/DC1 V2LWA3/UNV1 V2LWA3/DC1 /2” Wall with Junction Box V2LCHBF1/UNV1*** V2LCHBF1/DC1 V2LWHBF1/UNV1 V2LWHBF1/DC1 /4” Wall with Junction Box V2LCHBF2/UNV1*** V2LCHBF2/DC1 V2LWHBF2/UNV1 V2LWHBF2/DC1 /2” Ceiling V2LCHF1/UNV1*** V2LCHF1/DC1 V2LWHF1/UNV1 V2LWHF1/DC1 /4” Ceiling V2LCHF2/UNV1*** V2LCHF2/DC1 V2LWHF2/UNV1 V2LWHF2/DC1 /2” VXT Wall V2LCHT1/UNV1*** V2LCHT1/DC1 V2LWHT1/UNV1 V2LWHT1/DC1 /4” VXT Wall V2LCHT2/UNV1*** V2LCHT2/DC1 V2LWHT2/UNV1 V2LWHT2/DC1 /2” VXW Wall* V2LCHW1/UNV1*** V2LCHW1/DC1 V2LWHW1/UNV1 V2LWHW1/DC1 3 /4” VXW Wall* V2LCHW2/UNV1*** V2LCHW2/DC1 V2LWHW2/UNV1 V2LWHW2/DC1 11/4” Stanchion* V2LCHJ4/UNV1*** V2LCHJ4/DC1 V2LWHJ4/UNV1 V2LWHJ4/DC1 Adapter Only** V2LCHR/UNV1*** V2LCHR/DC1 V2LWHR/UNV1 V2LWHR/DC1 1 3 1 3 1 3 1 *For use in Class I, Division 2 or Class II, Division 1, Groups F, G. For Class II, you must order complete catalog number (not available for purchase in components). **For use when wall mount or ceiling mount box is already installed. ***5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium® approved models. Cool white only. Dimensions: Ordering Information - IECEx/ATEX: Cool White Warm White AC Drive AC Drive /2” Pendant NV2LCA1/UNV1 NV2LWA1/UNV1 3 /4” Pendant NV2LCA2/UNV1 NV2LWA2/UNV1 1” Pendant NV2LCA3/UNV1 NV2LWA3/UNV1 /2” Wall with Junction Box NV2LCHBF1/UNV1 NV2LWHBF1/UNV1 /4” Wall with Junction Box NV2LCHBF2/UNV1 NV2LWHBF2/UNV1 1 3 NV2LWHF1/UNV1 /4” Ceiling NV2LCHF2/UNV1 NV2LWHF2/UNV1 4 3/4 [121.3] NV2LCHT1/UNV1 NV2LWHT1/UNV1 /4” Wall NV2LCHT2/UNV1 NV2LWHT2/UNV1 11/4” Stanchion NV2LCHJ4/UNV1 NV2LWHJ4/UNV1 8 3/4 [221.7] 4 1/2 [114.7] 4 11/16 [119.8] 3 7/8 [99.2] VLA1 1/2" NPT HUB VLA2 3/4" NPT HUB VLA3 1" NPT HUB 1 [25.4] 1 3/4 [44] 1 3/4 [44] 2 1/8 [53.9] 7 1/16 1 [179.7] [25.4] 1 [25.4] 1 3/4 [44] Stanchion Ceiling Note: For IEC applications, you must order complete catalog number (not available for purchase in components). 5 7/8 [149.1] 1 3/4 [44] 1/4 [5.6] 1 [25.4] 2L /2” Wall 3 1 15/16 [23.9] 3 7/8 [99] NV2LCHF1/UNV1 3 6 7/8 [175] 3/4" NPT HUB 1/2" REDUCER SUPPLIED /2” Ceiling 1 11 1/4 [285.1] 8 3/4 [221.7] Mounting Style 1 Wall Pendant 8 3/4 [221.7] 11 13/16 [299.9] 8 1/8 [206.7] Weights: Luminaire & Mounting Module Weight Lbs. Pendant Mount Ceiling Mount Wall Mount Stanchion Mount 5.7 6.8 7.9 6.5 Ø4 9/16 [Ø116.0] Ø1/4 [Ø7.1] 1-1/4" HUB Ø4 15/16 [125.2] 5 1/2” NPT OR 3/4" NPT HUB 3 7/8 [98.5] 2 1/8 [53.4] 5 3/4 [146.2] 8 3/4 [221.7] Family Tree: Temperature Ratings: Max. Temp. °C Temp. Rating† V2LC/UNV1 V2LC/UNV1 S902 V2LC/DC1 40 55 40 T5 T4A T5 NV2LC/UNV1 40 T4 NV2LC/UNV1 S902 55 T4 Class I, Div. 2; Class II, Div. 1, Gr. F&G VXJ4 VXW2 VLA1 VLA2 VLA3 †Contact your local sales representative for warm white temperature ratings. www.crouse-hinds.com 45° VXT20 VXF 10 VXFT 10 VXF 20 VXFT20 VLHR V2L LED Housing US: 1-866-764-5454 Class I, Div. 2; Class II, Div. 2, Gr. F&G VXF 10 VXFT 10 VXF 20 VXFT20 CAN: 1-800-265-0502 VAPORGARD V2L SERIES Complete luminaire consists of LED Housing and Cover: a VLA pendant, or a VLHR adapter and VX series mounting module shown. Copyright© 2013 Eaton’s Crouse-Hinds Business 935 936-937.qxp 12/16/2013 7:09 PM Page 936 Vaporgard™ LED Series Luminaires 2L Leading the way in LED technology for industrial and hazardous applications UL Listed & CSA Certified Wet Location NEMA 4X IP66 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 1, Groups F, G IECEx/ATEX Photometric Data: Vaporgard™ LED (22 Watt) DISTANCE TO MOUNTING HEIGHT Isofootcandle chart shows illuminance in foot-candles at ground level 3 CANDLEPOWER DISTRIBUTION (IN CANDELAS) 2 1 0 -1 -2 1000 -3 1500 -3 -2 -1 0 1 2 3 2000 ISOFOOTCANDLE CHART 2500 Footcandle Values for Isofootcandle Lines 3000 3500 A 4000 B C D E F 4500 5000 2L 5500 ZONAL LUMENS 936 ZONE LUMENS % LUMEN 0-30 468 28.65 0-40 772 47.30 0-60 1374 84.15 0-90 1633 100.00 40-90 860 52.70 60-90 259 15.85 90-180 0 0.00 0-180 1633 100.00 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Mtg. Hgt. A B C D E F 6’ 10.00 5.00 2.00 1.00 0.50 0.20 8’ 5.62 2.81 1.13 0.56 0.28 0.11 10’ 3.60 1.80 0.72 0.36 0.18 0.07 12’ 2.50 1.25 0.50 0.25 0.13 0.05 14’ 1.84 0.92 0.37 0.18 0.09 0.04 Copyright© 2013 Eaton’s Crouse-Hinds Business 936-937.qxp 12/16/2013 7:09 PM Page 937 Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0ºC to 55ºC N2LPS LIGHT-PAK™ Emergency Lighting System Applications: LED N2LPS Light-Pak™ emergency lighting systems are used: • To provide reliable illumination for egress areas during failure or interruption of power to the normal lighting system • In areas where flammable gases or vapors may become present due to abnormal, unusual, or accidental conditions • In manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, oil terminals, food processing facilities, breweries, and other industrial manufacturing or process industry facilities subject to wet or corrosive conditions • To illuminate machinery or panels during a loss of AC power • Where moisture, dirt, dust, or corrosion will limit the life and reliability of ordinary emergency lighting systems • Where required by the National Electrical Code®, the Life Safety Code® or other applicable codes • Outdoor applications Features: Certifications and Compliances: NEC/CEC: • Class I, Division 2, Groups B, C, D, Zone 2 UL Standards: • 1598A (Supplemental Requirements for Luminaires for Installation on Marine Vessels) • 924 (Emergency Lighting and Power Equipment) • 844 (Electric Luminaires Hazardous Locations) CSA Standards: • C22.2 No. 141-M1985 unit equipment for emergency lighting • C22.2 No. 137-M1981 non-incendive electrical equipment for use in Class I, Division 2 hazardous locations • Life Safety Code NFPA101® – Section 5-9 (Emergency Lighting) • Marine wet locations suitability, Type 4X Standard Materials: • Power supply and remote luminaire enclosures – Krydon® fiberglassreinforced polyester • LED lamp head assembly – epoxy powder coated stainless steel • Exterior hardware – nylon, plastic coated, and stainless steel • Cover gasket – Hypalon® synthetic rubber Temperature Performance Data: Based on 55°C ambient Class I, Cat. # Division 2 N2LPS (all) N2RF (all) Note: 40ºC - T5; 55ºC - T4A T5 Electrical Ratings: • Power supply – Input: 120, 220, 230, 240, or 277 VAC, 50 or 60 Hz; 9 watts max. Output: 18 watts max. at 12 VDC • Luminaire heads – Voltage: 12 VDC; Lamp: 3 watt LED Total lumen output: 80 Unit Net Weights: • • • • N2LPS12222 – 16 lbs. N2LPS12220 – 12 lbs. N2RF1221 – 8 lbs. N2RF1222 – 9 lbs. Options: Description Suffix 55°C suitability . . . . . . . . . . . . . . . . .S904 2L • Compact, factory-assembled luminaire featuring LED lamps for improved lumen performance, on-time, and lamp life • Nonmetallic, enclosed, and gasketed housing provides corrosion protection in the most extreme environments • Durable and marine rated LED lamp head assemblies provide protection against water ingress, corrosion, and impact • High temperature rated nickel cadmium battery for reliable operation up to 55ºC ambient • Solid state battery charger for long life and reliable battery operation prevents deep discharge by automatically disconnecting the battery from the luminaire • Factory-installed "push-to-test" button • Self-test, monitoring, and diagnostics reduce costly maintenance checks • Remote luminaire head assemblies (one or two) are available for mounting of luminaire heads away from main power system • Stainless steel drain minimizes moisture collection • Standard battery disconnect switch (Krydon® unit) 2L Class II, Division 1 T6 T6 Ambient temperature at which the Light-Pak system is rated is 0°C to 55°C. Operation at temperatures outside this range will affect the battery life and/or charging performance. Note: Battery time in emergency mode is 90 minutes. National Electrical Code and Life Safety Code are registered trademarks of the National Fire Protection Association, Inc. Noryl is a registered trademark of General Electric Company. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 937 938-939.qxp 12/16/2013 7:09 PM Page 938 N2LPS LIGHT-PAK™ Emergency Lighting System 2L Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0ºC to 55ºC Ordering Information: Description Cat. # 28 watt, 12 volt power supply assembly with two 3 watt LED lamp heads 28 watt, 12 volt stainless steel power supply assembly with two 3 watt LED lamp heads 28 watt, 12 volt power supply assembly less luminaire heads Remote luminaire assembly with one 3 watt LED lamp head Remote luminaire assembly with two 3 watt LED lamp heads 28 watt, 120V LED Light-Pak with single sided exit sign** 28 watt, 277V LED Light-Pak with single sided exit sign** 28 watt, 120V LED Light-Pak with double sided exit sign** 28 watt, 277V LED Light-Pak with double sided exit sign** N2LPS12222 N2LPS12222 SS N2LPS12220* N2RF1221* N2RF1222* N2LPS12222/120 N2LPS12222/277 N2LPS12222/120 N2LPS12222/277 EXS DR0391734 EXS DR0391734 EXD DR0391734 EXD DR0391734 *Not cUL approved. UL Listed only. **Exit sign operates in both normal and emergency mode. Note: Up to four (4) remote LED lamp assemblies can be connected to the N2LPS12222. Up to six (6) remote LED lamp assemblies can be connected to the N2LPS12220. Wire Sizing for Remote Installation: For Copper Wire – Running Distance† (ft.) Between Power Supply and Remote Luminaire Load In Watts Wire Size 8 16 24 32 Wire Size Load In Watts 8 16 24 32 16 AWG 14 AWG 12 AWG 106 168 270 26 42 67 13 21 33 26 42 66 13 21 33 6 10 16 3 5 8 10 AWG 8 AWG 6 AWG 53 84 135 †Maximum distance to limit line voltage drop to 5%. Dimensions (N2LPS): 1.1 2L 13.5 16.0 7.5 5.0 13.8 14.5 7.4 18.0 Standard – N2LPS LED Light-Pak™ 938 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 938-939.qxp 12/16/2013 7:09 PM Page 939 N2LPS LIGHT-PAK™ Emergency Lighting System 2L Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0ºC to 55ºC Dimensions (N2LPS): EXS, EXD Option – N2LPS LED Light-Pak™ with Optional Emergency Exit Luminaire Dimensions (N2RF): 9.50 9.50 2L 3.83 3.83 7.27 4.38 11.77 Detail Indication Logic: Status Indication * *-* **-** ***-*** Status Description No Light Steady Light (No Blinks) Light Blinks Once Light Blinks Twice Light Blinks Three Times www.crouse-hinds.com Status Definition AC Power Removed from Circuit Fully Charged Battery Charging Battery Failure Circuit Failure US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 939 940-941.qxp 12/16/2013 2L 7:11 PM Page 940 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, AEx em ib IIC (NEC) Cl. I, Zone 1, Ex em ib IIC (CEC) Cl. II, Div. 2, Groups F, G (NEC) Cl. II, Div. 2, Groups E, F, G (CEC) Ex-Lite LED Exit Signs UL Listed IP66 The Ex-Lite Series of LED exit signs are designed for hazardous locations and are ideally suited for marking escape routes and exits in potentially explosive atmospheres. The Ex-Lite Z is available as an AC only version, while the Ex-Lite ZE is available with self-contained battery. As an emergency lighting luminaire with selfcontained battery system, the Ex-Lite ZE features a nickel cadmium battery with automatic test and monitoring feature. Applications: • In harsh and hazardous environments where illuminated exit signs are required 2L Features and Benefits: LED Technology: • Long life (>50K hours) for years of maintenance-free operation • Energy-efficient for lower cost of operation • Low temperature operation with no loss of illumination • Rugged and durable light source for the harshest of environments Exit Sign System: • Can be used in a hazardous location • Conduit or cable entry • Can be installed in moist, humid, rain, and wet environments • Universal input voltage 110VAC-277VAC and 110VDC-250VDC reduces inventory • Ex-Lite ZE with self-monitoring, selfdiagnostic, and test capability • Premium heavy-duty nickel cadmium battery • 24-hour charge and recharge time increases safety by recovering quickly from outage • "EXIT" legend with alternative wings left, right, or left and right; simple field modification • Emergency lighting cycle three hours • The housing of the luminaire is constructed with a corrosion resistant, robust, lightweight aluminum alloy material and illumination of the sign is provided with red, high-efficient LEDs Ordering Information: Catalog Number Ex Lite Z Ex Lite ZE Material Number Description Light Source Life of LED Rated Voltage, VAC Frequency, Hz Rated Voltage, DC Power Consumption Battery 12191001005 AC/DC Exit Sign LED 50K hours 120V-277V 50/60 110V-250V 6VA N/A 12191130005 with Battery LED 50K hours 120V-277V 50/60 110V-250V 6VA NiCad Allowable Temperature Range -4ºF to 122ºF (-20ºC to 50ºC) 41ºF to 95ºF (5ºC to 35ºC)* Mounting Cable Entry Conduit Entry Protection Wall Ex-e 3 /4” IP66 Wall Ex-e 3 /4” IP66 *Due to battery chemistry, the charging capacity will be limited at temperatures below 5ºC and above 35ºC. Dimensions In Inches (mm): Certifications and Compliances: • • • • • • • • • • Class I, Division 2, Groups A, B, C, D Class I, Zone 1, AEx em ib IIC (NEC) Class I, Zone 1, Ex em ib IIC (CEC) Class II, Division 2, Groups F, G (NEC) Class II, Division 2, Groups E, F, G (CEC) IP66 UL844 UL924/CSA22.2 No. 141-02 UL60079/CSA22.2 E60079 UL1203/CSA22.2 E6124-1-1-02 940 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 940-941.qxp 12/16/2013 7:11 PM Page 941 CCH UX Series LED Exit Signs 2L NEMA 4X, IP66 UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating Eaton's Crouse-Hinds CCH UX Series LED Exit Sign combines the strength and durability of die cast aluminum with architecturallypleasing aesthetics. The CCH UX Series is illuminated by LEDs, providing the customer with a long-life, low maintenance, dependable exit sign for use in conditions where reliability is crucial. Designed for the most severe environments, the CCH UX Series will provide maximum performance against rain, moisture, cold, corrosion, and dust in applications such as manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, food processing, and other industrial facilities. Applications: • In locations deemed hazardous due to the presence of flammable vapors or gases • In areas where the presence of gases or vapors may become present during an abnormal, unusual, or accidental conditions • Outdoor and wet applications • Where required by the National Electrical Code®, Life Safety Code®, or other applicable codes Features and Benefits: NEMA 4X, UL50 UL924 wet location IP65, IP66 Available with NEC hazardous location rating - UL844 Class I, Division 2, Groups A, B, C, D CCH UX Series Exit Sign: • -45ºC (-49ºF) to 45ºC (113ºF) CCH UX-HAZ Hazardous Location Exit Sign: • T6 rating at 45ºC (113ºF) Electrical Ratings: • Power Supply 120V/277V dual voltage • LED Exits - Red Input Power 120V = 2.7W 277V = 3.2W • LED Exits - Green Input Power 120V = 2.3W 277V = 3.0W Input Current: (Max.) 120V = .08A 277V = .03A Ordering Information: Dimensions In Inches: Mounting: wall mount, ceiling mount, end mount Conduit Entry: top, bottom, or either side of the unit www.crouse-hinds.com Temperature Performance Data: Input Current: (Max.) 120V = .07A 277V = .04A Certifications and Compliances: • • • • • Provides safe and reliable exit marking both indoors and outdoors during power failure or interruption of power to normal lighting system • Long life (>50K hours) for years of maintenance-free operation • Energy-efficient for lower cost of operation • Low temperature operation with no loss of illumination • Rugged and durable light source for the harshest of environments 2L • Wet location, outdoor rated for use in the most demanding environments • Optional hazardous location rating available • Dual voltage 120V/277V reduces wiring errors • Heavy-duty nickel cadmium battery for long life • 24-hour charge and recharge recovery time increases safety • Heavy-duty injection molded polycarbonate lens protects against impact and corrosion • Brown-out protection protects battery and reduces labor • Heavy-duty aluminum die cast housing protects against impact and chemical resistance • LEDs provide long life, even illumination, and energy savings • Wide operating temperature range (-45°C to 45°C) • Self-diagnostic testing reduces costs by eliminating scheduled equipment verification tests • Heavy duty nickel cadmium battery for long life meets 90 minute requirements for battery operated emergency system Benefits of LED Technology: US: 1-866-764-5454 Catalog Number Housing Finish Letter Color CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH Silver Housing Silver Housing Silver Housing Silver Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Red LED Red LED Green LED Green LED Red LED Red LED Red LED Red LED Red LED Red LED Green LED Green LED Green LED Green LED Green LED Green LED UX70RSDHAZ UX60RHAZ UX70GSDHAZ UX60GHAZ UX70RSD UX70RWHSD UX70RBKSD UX60R UX60RWH UX60RBK UX70GSD UX70GWHSD UX70GBKSD UX60G UX60GWH UX60GBK CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 941 942-943.qxp 12/16/2013 7:13 PM Page 942 Pro Series Industrial LED Luminaires 2L The robust Pro Series LED family allows for replacement of existing HID, floodlights, and incandescent industrial fixtures, and provides an energy-efficient, proven light source for use in applications where reliability is crucial. PRO SERIES LED BENEFITS B A Customized heat sinks Eaton’s Crouse-Hinds’ heat sinks are specifically engineered to remove heat from the LEDs and driver to ensure longer life, better lumen output, and accurate color temperature. A Applications: B Retrofittable mounting modules • Robust Pro Series LED family allows for replacement of existing HID, floodlights, and incandescent industrial fixtures • Locations requiring continuous and consistent light levels in extreme ambient temperatures • Areas requiring frequent on-and-off of lights • Areas that are difficult to relamp or that cause production to be stopped during the lamp maintenance process • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist • Type 4X, marine, wet locations and hose-down environments • Warehouses, outdoor areas, production facilities, etc. Compact modular fixtures attach to existing Eaton’s Crouse-Hinds installed mounting modules, reducing installation costs. C C Long life LEDs eliminate maintenance cost Eaton’s Crouse-Hinds’ luminaires remove the high maintenance costs associated with traditional lamps. 2L Product Selector Chart: Series Champ® Pro PVM Series UL1598; UL1598A; cUL; Type 4X; IP66; CE Champ® Pro PFM Series UL1598; UL1598A; cUL; NEMA 4X; IP66 Vaporgard™ Pro P2L Series UL1598; UL1598A; cUL; NEMA 4X; IP66 Applications / Uses • General high bay/low bay illumination • Outdoor/indoor flood illumination • Low mounting heights, such as stairways, walkways, and doorways • Targeted illumination Equivalent Output Replaces 70W to 400W HID Replaces 70W to 400W HID Replaces up to 200W incandescent Mounting Styles Wall; Ceiling; Pendant; Flexible Pendant; Cone Pendant; Stanchion Yoke Mounted Wall; Ceiling; Pendant; Stanchion Photometrics and Test Reports Available • IES Photometric Files • LM-80 Lumen Maintenance Report • LM-79 Test Report • IES Photometric Files • LM-80 Lumen Maintenance Report • LM-79 Test Report • IES Photometric Files • LM-80 Lumen Maintenance Report • LM-79 Test Report Certifications 942 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 942-943.qxp 12/16/2013 7:13 PM Page 943 Champ® Pro PVM Series Luminaires 2L UL/cUL Listed Type 4X IP66 Ideal for general high bay/low bay illumination The Champ® Pro PVM Family Champ® Pro PVM Series Luminaires are designed to provide full-spectrum, crisp, white light with custom IES Type I, III, and V distribution. Five versions of the PVM Series are available, providing ideal solutions for a wide range of applications. Model Nominal† Lumens (Type V) Wattage Equivalent HID Luminaire Typical Energy Savings / Lifetime PVM3L PVM5L PVM7L PVM9L PVM11L 3,515 5,288 7,404 9,515 10,935 70W-100W 100W-150W 150W-175W 250W-400W 400W Up Up Up Up Up 41 67 94 114 118 to to to to to 77% 67% 67% 74% 74% †Tolerance +/- 10%. Applications: • Locations requiring continuous and consistent light levels in extreme ambient temperatures • Areas requiring frequent on-and-off of lights • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist • Manufacturing plants; heavy industrial, chemical, petrochemical, or pharmaceutical facilities; food and beverage facilities; mining; platforms; loading docks; tunnels; indoor/outdoor spot lighting; outdoor wall and stanchion mounted general area lighting Certifications and Compliances: Custom Optics: *Cool white 120-277 VAC 3L-11L models. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. • Instant illumination and restrike • Better visibility with crisp, white light • Cold temperature operation / no warmup required • Redundancy in drivers with multiple series circuits connected to each driver to avoid complete loss of illumination • Easy installation - compact modular fixture attaches onto existing Champ® mounting module • Energy-efficient technology - up to 77% energy savings over HID fixtures • Provides up to 60,000 hours rated life and up to 170,000 hours of economic life - eliminates need for frequent lamp replacement • Contains no mercury or other hazardous substances • Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break - greatly reduces the risk of premature failure • Operating ambient -40°C to 55°C • Dark sky compliant • 5 year fixture warranty†† LED System: TYPE I Ideal for: • Mining conveyor belts • Aisleways and hallways • Catwalks and walkways • Ramps and loading docks • Tunnels with overhead mounts TYPE III Ideal for: • Narrow crosswalks or passages with wall mounted fixtures • Tunnels with wall mount • Wall or stanchion mount requiring 180° forward throw beam patterns • High intensity discrete power emitters • Cool white (5000K, 70 CRI) and warm white (3000K, 80 CRI) • Custom optics designed to go over each discrete LED TYPE V Ideal for: • Pendant, ceiling or stanchion mount overhead building mounts • Processing mills, industrial plants, large buildings, warehouses, etc. Standard Materials: • Lamp housing and adapter – die cast aluminum with Corro-free™ epoxy powder coat • Lens – heat- and impact-resistant glass • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required 2L Champ Pro PVM LED Benefits: ††Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. Three optical options to maximize light distribution and intensity: • DesignLights Consortium® for select models* (pending) NEC and CEC • Wet Locations, Type 4X, IP66 UL Standards • UL1598 Luminaires, UL1598A Marine CSA Standard • cUL Listed to CSA Standard CSA C22.2 No. 250 IEC Standard • CE Drivers: Option 3L - 11L /UNV1 /UNV34** /VDC‡ 120-277 VAC, 50 / 60 Hz 347-480 VAC, 50 / 60 Hz 108-250 VDC, 50 / 60 Hz **No separate external transformer required to step down voltage. ‡Separate driver for DC applications. Electrical Ratings: PVM3L PVM5L PVM7L PVM9L PVM11L Voltage Range, VAC 120-277 120-277 120-277 120-277 120-277 Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Input Power (Watts) 41 67 94 114 Input Amps at 120-277 VAC 0.34-0.17 0.57-0.29 0.80-0.42 0.96-0.49 0.96-0.49 Voltage Range, VDC 108-250 108-250 108-250 108-250 108-250 Power Factor >0.90 >0.90 >0.90 >0.90 >0.90 Nominal Lumens† (Type V) 3,515 5,288 7,404 9,515 10,935 118 †Tolerance +/- 10%. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 943 944-945.qxp 12/16/2013 7:14 PM Page 944 Champ® Pro PVM Series Luminaires 2L UL/cUL Listed Type 4X IP66 Ideal for general high bay/low bay illumination Design Features: A A Installation and replacement made simple - this contractor-friendly, modular design is ideal for both retrofit and new construction applications. These luminaires are installed in the same manner and use the same mounting modules as existing Champ® Series luminaires. The compact modular design of the PVML allows for easy component replacement and future upgrade. B High efficiency and lumen output - custom high efficiency LED drivers are designed to provide reliable operation in even the harshest environments. Various AC and DC input voltage options are available to suit virtually any drive requirement. C Safe, reliable heat transfer - die cast aluminum housing provides safe and effective heat transfer from the LED assembly to the outside environment, ensuring low LED junction temperature, reliability, and sustained lumen performance. The vertical fin design facilitates air flow and dust shedding. The impact-resistant lens is sealed from the outside environment and provides ingress protection against water and dust. D Custom optics - custom optics designed for discrete LED power emitters. E Ease of wiring and installation - available with lever lock connectors and standard three-pole terminal block for ease of wiring and installation. E B C D Custom Optics: Custom optics designed for discrete LED power emitters: • Type V standard • Type I and Type III optional Colored LED Options: Available in red, blue, green and amber Reduction in light pollution for night space observation and sky glow due to isolating blue wavelength in red and amber colors Wildlife friendly Improves visibility for telescopes in observatories during night sky space exploration 2L • • • • Type I Type III Type V Options: Description Wire guard with captive mounting hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trunnion mount with redundant pin locking mechanism (ceiling mount required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Clip for quick installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diffused lens for glare reduction‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Teflon coating on lens for additional shatter protection‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polycarbonate lens available in applications where glass is prohibited . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Six-pole terminal block‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Suffix P3001 S812 K1 S890 S891 S896 S903 TB6 ‡‡Not available for IEC applications. Accessories (Ordered Separately): Description Photocell, 120V, 50 / 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Photocell, 208-277V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Occupancy sensor, 1/ 2" entry, 120/ 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Occupancy sensor, 3/ 4" entry, 120/ 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Occupancy sensor, 1" entry, 120/ 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ***For 347-480 VAC, replace /UNV1 with /UNV34. 944 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Cat. # (Ordered Separately) D2S20 D2S208 277 COS1/UNV1 COS2/UNV1 COS3/UNV1 944-945.qxp 12/16/2013 7:14 PM Page 945 Champ® Pro PVM Series Luminaires 2L UL/cUL Listed Type 4X IP66 Ideal for general high bay/low bay illumination Catalog Numbering System: PVM 7L W 2A R1 G /UNV1 S890 Lamp/Function 3L 3,515 Lumen LED 5L 5,288 Lumen LED 7L 7,404 Lumen LED 9L 9,519 Lumen LED 11L 10,935 Lumen LED RL Red (3,200 Lumen) /UNV1 GL Green (4,300 Lumen) BL Blue (2,100 Lumen) AL Amber (5,000 Lumen) Color Temperature BLANK Suffixes Guard Cool BLANK No Guard S812 Trunnion Mount Kit with Pin (5000 ± 200K) G P3001 Wire Guard S890 Quick Clip S891 Diffused Lens† S896 Teflon Coated Lens† 120-277 VAC, 50/60 Hz S903 Polycarbonate Lens /UNV34 347-480 VAC, 50/60 Hz TB6 Six-pole Terminal Block† /VDC 108-250 VDC, 50/60 Hz Warm W Voltage (3000K ± 200K) Mounting Style BLANK No Cover J 1-½” Stanchion 25° P 1-½” Stanchion Straight 2A ¾” Pendant 3A 1” Pendant 2B ¾” Cone Pendant 3B 2C 3C 2HA Optics 1” Cone Pendant ¾” Ceiling 1” Ceiling ¾” Flexible Pendant 2TW ¾” Wall 3TW 1” Wall BLANK Type V Optic Standard (All Mounts) R1 Type I Optic (All Mounts Minus Ceiling) R1A Type I Optic (Ceiling with Conduit 45° Counterclockwise or 135° Clockwise from Hinge)* R1B Type I Optic (Ceiling with Conduit 45° Clockwise or 135° Counterclockwise from Hinge)* R3 Type III Optic (All Mounts Minus Ceiling) R3A1 Type III Optic (Ceiling with Conduit 45° Counterclockwise from Top Hat Hinge)** R3A2 Type III Optic (Ceiling with Conduit 135° Clockwise from Top Hat Hinge)** R3B1 Type III Optic (Ceiling with Conduit 45° Clockwise from Top Hat Hinge)** R3B2 Type III Optic (Ceiling with Conduit 135° Counterclockwise from Top Hat Hinge)** *For new construction, order R1A only. **For new construction, order R3A1 only. †Not available for IEC applications. Dimensions: Pendant Ceiling Wall Trunnion 354.6 13.96 50.8 2.00 295.2 11.62 BRACKET FOR WALL MOUNT OR SFA6 SLIPFITTER 118.6 4.67 258.6 10.18 295.1 11.62 Cone Pendant 300.4 11.83 71.2 2.80 2X LOCKING PINS 2X TRUNNION ROTATION HARDWARE 117.5 4.63 51.6 2.03 279.4 11.00 158 6.22 CM2 OR CM3 TOP HAT 287.3 11.31 280.1 11.03 2L 273.5 10.77 386.6 15.22 2X TOP HAT MOUNTING HARDWARE 225.6 8.88 Stanchion Angled Stanchion Straight 407.2 16.03 Weights: 382.7 15.07 88.7 3.49 273.8 45.2 10.78 1.78 53.4 2.10 326.3 12.85 282 11.10 25° 247.7 9.75 www.crouse-hinds.com Net Luminaire Weight: 21.8 lbs. 8.07 kg. Mounting Module add (lb.) Pendant Cone Pendant Flexible Pendant Ceiling Wall Angle Stanchion Straight Stanchion 1.25 4.00 1.50 2.75 4.50 3.50 4.50 0.57 1.81 0.68 1.25 2.04 1.59 2.04 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 945 946-947.qxp 12/16/2013 7:14 PM Page 946 Champ® Pro PVM Series Luminaires 2L UL/cUL Listed Type 4X IP66 Ideal for general high bay/low bay illumination Family Tree: MOUNTING MODULE SERIES ANGLED BPM2 BPM3 PENDANT APM2 APM3 HPM2 CEILING CM2 CM3 STANCHION PM5 JM5 WALL TWM2 TWM3 VMV*L PVM*L Photometric Data: Photometric Layout Comparison - Champ® PVM7L LED Versus 175W Metal Halide: PVM7L - Type I VMV 175W PSMH - Type I 50 50 40 30 20 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.6 0.6 0.6 0.7 0.7 0.6 0.6 0.6 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.4 0.1 0.2 0.3 0.2 0.2 0.3 0.2 0.3 0.4 0.5 0.6 0.4 .5 0.5 0.7 1.0 1.5 0.1 10 0 0.6 0.5 1.75 40 30 20 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.8 0.7 0.7 0.8 0.7 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.2 0.3 0.4 0.4 0.4 0.2 0.2 0.4 0.5 0.4 0.3 0.3 0.2 0.7 1.0 1.1 1.1 1.4 1.4 1.1 1.1 1.0 0.7 0.5 0.3 0.2 0.2 0.1 0.2 0.3 0.5 0.6 0.8 1.0 1.0 0.6 1.0 1.0 0.8 0.7 0.5 0.4 0.3 0.9 1.1 1.3 2.1 2.6 2.6 2.1 1.3 1.1 0.9 0.6 0.5 0.4 0.3 0.2 0.3 0.5 0.7 0.9 1.2 1.7 2.4 2.7 3.0 3.2 3.3 3.0 2.7 2.4 1.8 1.3 1.0 0.7 0.5 0.4 2.0 2.1 2.1 3.0 2.9 2.9 3.0 2.1 2.1 2.0 1.5 1.0 0.7 0.5 0.4 0.4.5 0.6 0.9 1.2 1.75 1.7 2.4 3.5 4.8 6.3 7.3 7.2 6.3 4.7 3.4 2.5 1.7 1.3 0.9 0.7 0.5 6.3 4.7 3.4 2.5 1.7 1.3 0.9 0.7 0.5 10 0 -10 -20 -30 -40 -50 .5 0.5 .75 0.7 11.0 1.5 1.5 22.0 2.1 0.2 0.3 0.4 0.5 0.6 0.9 1.1 1.2 1.9 0.1 0.2 0.2 0.3 0.5 0.7 1.0 1.1 1.0 0.1 0.1 0.2 0.3 0.4 0.6 0.8 0.8 0.8 0.1 0.1 0.2 0.2 0.3 0.5 0.5 0.6 0.6 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 2.1 2.9 2.6 2.6 2.9 2.4 2.4 1.3 1.3 0.8 0.6 0.4 0.2 2.0 1.5 2.1 2.1 1.0 0.7 0.5 1.9 1.2 1.1 0.9 0.6 0.5 0.4 0.3 0.2 1.0 1.1 1.0 0.7 0.5 0.3 0.2 0.2 0.1 0.8 0.8 0.8 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.6 0.6 0.6 0.5 0.5 0.3 0.2 0.2 0.1 0.1 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.4.5 0.4 -10 -20 -30 -40 -50 0.6 .75 0.9 1 1.2 1.5 1.7 2 2.4 3.5 4 3 5 4.8 -40 -30 -20 -10 0 6 7 6.3 7.3 0.5 0.7 0.9 1.2 1.7 2.4 2.7 3.0 3.2 3.3 3.0 2.7 2.4 1.8 1.3 1.0 0.7 0.5 0.4 0.2 0.3 0.5 0.6 0.8 1.0 1.0 0.6 0.8 0.7 0.7 0.8 0.7 1.0 1.0 0.8 0.7 0.5 0.4 0.3 0.2 0.2 0.3 0.4 0.4 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.5 0.4 0.3 0.3 0.2 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10 20 30 40 50 0.0 -50 -40 -30 -20 -10 0 10 20 30 40 0.75 1 1.25 1.5 2 4 3 5 7 Label Calc. Type (in Fc) Avg. Max. Min. VMV 175W MH Grid Illuminance 0.49 3.0 0.0 PVM LED Grid Illuminance 0.58 7.3 0.0 50 Distance In Feet PVM7L - Type III VMV 175W PSMH - Type III 50 50 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.4 0.4 0.4 0.4 20 0.5 0.6 0.7 0.7 0.6 0.4 0.5 0.6 0.6 0.7 0.7 0.6 0.6 0.5 0.4 0.6 0.7 0.7 0.6 0.5 1.1 10 0.5 2.1 40 30 0.8 1.0 1.1 0.7 0.8 0.7 11.0 1.5 1.8 1.2 0.5 0.8 1.2 1.72 2.6 2.9 2.0 0.3 0.5 0.7 1.0 1.5 2.0 2.0 0.2 0.2 0.3 0.4 0.6 0.9 1.3 1.6 0.2 0.2 0.3 0.4 0.5 0.8 1.0 0.1 0.2 0.3 0.4 0.5 0.7 0.1 0.2 0.2 0.3 0.4 0.6 0.1 0.2 0.2 0.3 0.3 0.4 0.1 0.1 0.2 0.2 0.3 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.6 0.4 0 .25 0.2 .5 1.2 1.9 1.5 2.5 4 0.8 0.9 0.9 0.8 0.8 0.7 1.1 1.1 1.1 1.1 1.2 1.8 2.4 3.3 3.3 2.4 2.0 2.9 4.5 3.7 3.7 4.5 2.0 2.0 1.1 1.2 1.1 2.1 1.9 1.5 1.0 0.7 0.5 2.6 1.7 1.2 0.8 0.5 0.4 1.5 1.0 0.7 0.5 0.3 0.2 1.0 0.8 40 30 20 0.6 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.6 0.6 0.6 0.5 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.9 1.1 1.2 1.2 1.1 0.9 0.7 0.5 0.4 0.3 0.2 0.2 0.1 1.1 1.5 2.0 0.2 0.2 0.2 10 0 0.4 0.5 0.7 0.2 0.2 0.3 0.5 0.7 1.0 0.2 0.3 0.4 0.5 0.8 1.3 0.2 0.3 0.2 0.4 0.3 0.6 0.9 1.4 2 0.2 .25 0.3 0.4 0.5 0.8 1.2 1.5 0.2 0.2 0.3 0.4 0.6 0.8 0.1 0.2 0.2 0.3 0.4 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.6 2.6 2.1 3.5 2.3 3 3.9 2.0 5.4 6.2 1.5 1.1 0.7 0.5 0.4 0.3 4.3 4.3 3.5 2.6 1.6 1.0 0.7 0.5 0.3 6.4 6.4 5.4 3.5 2.1 1.3 0.8 0.5 0.4 0.3 0.2 7.6 7.6 6.2 3.9 2.3 1.4 0.9 0.6 0.4 0.3 0.2 2.4 6 -10 -20 -30 -40 -50 2.8 2.8 3.8 1.6 1.3 0.9 0.6 0.4 0.3 0.2 0.2 1.2 1.5 2.9 2.9 1.5 1.2 1.0 0.8 0.5 0.4 0.3 0.2 0.2 0.9 1.0 1.1 1.2 1.2 1.1 1.0 0.9 0.7 0.5 0.4 0.3 0.2 0.1 0.7 0.9 0.9 0.9 0.9 0.9 0.9 0.7 0.6 0.4 0.3 0.2 0.2 0.1 0.5 0.6 0.7 0.7 0.7 0.7 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.3 0.4 0.4 0.4 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 -10 -20 -30 -40 -50 .5 -40 -30 -20 -10 0 0.2 2.9 4.6 5.9 5.9 4.6 2.9 1.8 1.2 0.8 0.5 0.4 0.3 0.2 1.0 1.4 2.2 4.0 4.0 2.2 1.4 1.0 0.8 0.6 0.4 0.3 0.2 0.2 0.4 0.5 0.5 0.9 1.3 1.3 0.9 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.2 0.2 0.3 0.5 0.6 0.6 0.5 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1 1.8 2.5 Point By Point Foot-Candles -50 0.2 TYPE III OPTICAL PATTERN 0.25 coo173140 3.8 3 2.4 4 3.5 5 VMVM2C175G243-S828 10 20 30 40 50 -50 -40 -30 -20 -10 0 10 20 30 40 0.5 1 1.5 2.5 2 4 3 5 6 Calculation Summary Point By Point Foot-Candles Distance In Feet Label Calc. Type (in Fc) Avg. Max. Min. VMV 175W MH Grid Illuminance 0.59 4.5 0.1 PVM LED Grid Illuminance 0.61 7.6 0.0 50 Distance In Feet VMV 175W PSMH - Type V PVM7L - Type V 50 50 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.5 0.6 0.7 0.7 0.7 0.7 0.6 0.5 0.3 0.3 0.2 0.2 0.1 0.1 20 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.8 0.9 1.0 1.0 0.9 0.8 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.9 1.1 1.2 1.3 1.3 1.2 10 0.1 0.2 0.2 0.4 0.6 0.8 1.1 1.3 1.4 1.7 1.7 1.4 1.3 1.1 0.8 0.6 0.4 0.2 0.2 0.1 0.1 0.2 0.3 0.4 0.7 0.9 1.2 1.4 2.2 2.8 2.8 2.2 1.4 1.2 0.9 0.7 0.4 0.3 0.2 0.1 0.1 0.2 0.3 0.5 0.7 1.0 1.3 1.75 1.7 2.8 2.6 2.6 2.8 1.7 1.3 1.0 0.7 0.5 0.3 0.2 0.1 0.1 0.2 0.3 0.5 0.7 11.0 1.3 1.7 2.8 2.6 2.6 2.8 1.7 1.3 1.0 0.7 0.5 0.3 0.2 0.1 0.1 0.2 0.3 0.4 0.7 0.9 1.2 2.2 2.8 2.8 2.2 1.4 1.2 0.9 0.7 0.4 0.3 0.2 0.1 0.1 0.2 0.2 0.4 0.6 .75 0.8 1.1 1.3 1.4 1.7 1.7 1.4 1.3 1.1 0.8 0.6 0.4 0.2 0.2 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.9 1.1 1.2 1.3 1.3 1.2 1.1 0.9 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.7 0.8 0.9 1.0 1.0 0.9 0.8 0.7 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.5 0.6 0.7 0.7 0.7 0.7 0.6 0.5 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 40 30 0 1.1 0.9 0.7 0.5 0.3 0.2 0.2 40 30 20 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.8 1.1 1.1 0.9 0.6 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.6 1.3 2.3 0.0 0.0 0.0 0.0 0.1 1.5 0.8 0.2 4.9 4.1 2.8 1.6 0.6 2.0 3.9 5.8 7.2 7.2 6.1 4.2 2.3 1.0 0.3 0.1 0.0 0.0 0.0 1.0 1.75 2.5 4.8 7 7.1 6.5 6.4 7.3 5 5.1 2.8 1.3 0.4 0.1 0.0 0.0 0.0 1 1.0 2 2.5 7.1 6.5 6.4 7.3 5.1 2.8 1.3 0.4 0.1 0.0 0.0 0.0 0.8 1.5 2.0 5.8 7.2 7.2 6.1 4.2 2.3 1.0 0.3 0.1 0.0 0.0 0.0 1.6 0.6 0.2 0.1 0.2 1.3 4.9 -10 -20 -30 -40 -50 .5 1.5 1.4 2 -40 -30 -20 -10 0 3L 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.3 0.0 0.0 0.0 0.1 0.3 -10 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.0 0.1 0.1 0.4 1.3 2.6 -20 0.0 0.0 0.0 0.0 0.1 0.2 0.6 1.3 2.1 2.6 2.6 2.3 1.5 0.8 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.8 1.1 1.1 0.9 0.6 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 TYPE V OPTICAL PATTERN 0.5 7L Type V -30 -40 -50 .5 4 3 4.8 3.9 10 6 3.9 4.9 4.9 4.1 2.8 0.0 0.0 20 30 40 50 -50 -40 -30 -20 -10 0 10 20 30 40 0.75 1 1.5 1.75 2 3 4 5 Label Calc. Type (in Fc) Avg. Max. Min. VMV 175W MH Grid Illuminance 0.51 2.8 0.1 PVM LED Grid Illuminance 0.69 7.3 0.0 50 Distance In Feet 5L 7L 9L 11L Type I 3,115 4,687 6,562 8,437 9,692 Type III 3,271 4,921 6,890 8,859 10,177 Type V 3,515 5,288 7,404 9,519 10,935 †Tolerance +/- 10%. www.crouse-hinds.com US: 1-866-764-5454 6 Calculation Summary 0.0 Point By Point Foot-Candles Distance In Feet Actual Lumens (Nominal†) 0.1 0.1 0.1 0.0 Point By Point Foot-Candles -50 0.1 0.1 0.0 0.0 0.8 3.9 2.6 0.0 0.0 0.0 .75 2.6 2.6 0.0 0.0 0 0.4 2.1 0.0 10 VMVM2C175G245-S828 946 6 Calculation Summary Point By Point Foot-Candles Distance In Feet 2L 7.2 0.3 Point By Point Foot-Candles -50 0.25 7L Type I VMVM2C175G241-S828 0.4 TYPE I OPTICAL PATTERN CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 7 946-947.qxp 12/16/2013 7:14 PM Page 947 Champ® Pro PFM Series Luminaires 2L UL/cUL Listed NEMA 4X IP66 Perfect for outdoor/indoor flood illumination Drivers: The Champ® Pro PFM Family Model Champ® Pro PFM Series Floodlights are designed to provide full-spectrum, crisp, white light. Five versions of the Champ PFM LED are available, providing ideal solutions for a wide range of applications. 90-305 VAC, 50 / 60 Hz; 108-250 VDC 347 VAC Model 480 VAC Model Standard Option 1 Option 2 Standard Materials: Champ® Pro PFM Model Equivalent MH HID Lamp PFM5L PFM7L PFM9L PFM11L PFM13L 100W-150W 150W-175W 175W-250W 250W-400W 400W Energy Savings • Housing – copper-free aluminum with Corro-free™ epoxy powder coat • Lens – shatter-resistant glass Up to 62%! • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required Certifications and Compliances: • • • • • 5L - 13L LED System: UL1598 UL1598A cUL NEMA 4X; IP66 DesignLights Consortium® approved for select models (refer to Ordering Information for details) • High brightness light emitting diode (LED) arrays • Color temperature: 3000K (CRI 82) and 5600K (CRI 65) options available • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions Electrical Ratings: PFM5L PFM7L PFM9L PFM11L PFM13L 100-277V 50-60 Hz Voltage Range, VAC 347 / 480V 60 Hz 108-250 108-250 108-250 108-250 108-250 Input Power (Nom.) 64 89 121 149 179 Input Amps (Max.) 0.550 0.800 1.083 1.608 1.608 Power Factor >0.85 >0.85 >0.85 >0.85 >0.85 2L Voltage Range, VDC Ordering Information: Color Temperature Cool Color Temperature 5L Series 7L Series 9L Series 11L Series 13L Series PFM5LCY/UNV1 76 PFM7LCY/UNV1 76 PFM9LCY/UNV1 76 PFM11LCY/UNV1 76 PFM13LCY/UNV1 76 PFM5LCY/120 76* PFM7LCY/120 76* PFM9LCY/120 76* PFM11LCY/120 76* PFM13LCY/120 76* Warm Color Temperature PFM5LWY/UNV1 76 PFM7LWY/UNV1 76 PFM9LWY/UNV1 76 PFM11LWY/UNV1 76 PFM13LWY/UNV1 76 For 347 VAC option, replace /UNV1 with /347. For 480 VAC option, replace /UNV1 with /480. To order fixture without optics, remove ‘76’ from the end of the catalog number. *5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium approved models. Cool white only. Options: Description Suffix Fused (only applies to UNV1 model, not available for 347V or 480V; NOT marine or cUL Listed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658 Two conduit/cable glands of like thread installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S886 Accessories: Description Catalog No. Sold Separately Bolt-on visor (sold separately) Bolt-on wire guard (sold separately) Floodlight slipfitter (sold separately) Slipfitter wall mount adapter (sold separately) DSV1 P61 SFA6 SWB6 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 947 948-949.qxp 12/16/2013 7:15 PM Page 948 Champ® Pro PFM Series Luminaires 2L UL/cUL Listed NEMA 4X IP66 Perfect for outdoor/indoor flood illumination Dimensions: [167.1] 6.6 [532.9] 21.0 [552.5] 21.75 [405.9] 16.0 [14] Ø.55 [120.7] 4.75 Photometric Data: Weights: Model Lbs. 5L 7L 9L 11L 13L 39.11 39.16 39.73 40.35 40.35 PFM13L @ 30 Ft. High; Tilt Angle = 45 Degrees (Isofootcandles) 2L Ambient Temperature: Champ® Pro PFM Model Max. Temp. ºC PFM5L 55 PFM7L 55 PFM9L 55 40 PFM11L 55 40 PFM13L 55 Point By Point FC Readings Distance in Feet .35 Fc .5 Fc 1 Fc 2 Fc 2.5 Fc MULTIPLIERS FOR OTHER LED FLOODLIGHTS Luminaire Series Wattage 64 4386 PFM7L 89 6720 PFM9L 121 8478 PFM11L 149 10420 *PFM 13L output is 12,940. 948 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Lumens* PFM5L Copyright© 2013 Eaton’s Crouse-Hinds Business 948-949.qxp 12/16/2013 7:15 PM Page 949 Champ® Pro PFM Series 25L and 50L LED Floodlights 2L UL/cUL Listed NEMA 4X IP66 The Champ® Pro PFM LED Family PFM LED Series Floodlights are designed to provide full-spectrum, crisp, white light. Two versions of the Champ Pro PFM LED are available, providing ideal solutions for a wide range of applications. PFM Model Equivalent HID Lamp Energy Savings PFM25L 750W MH 1500W MH / PFM50L 1000W HPS PFM25L Model Up to 65%! PFM50L Model Applications: Certifications and Compliances: Standard Materials: • Housing – copper-free aluminum with Corro-free™ epoxy powder coat • Lens – heat- and impact-resistant glass • Yoke mount (standard) – copper-free aluminum with Corro-free™ epoxy powder coat • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required LED System: • High brightness light emitting diodes (LEDs) • Color temperature: 5000K (CRI 67) • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions • LM-79, LM-80 reports available upon request Description Two conduit/cable glands of like thread installed ................... Diffused glass lens .................... Polycarbonate lens.................... Suffix S886 S891 S903 Accessories: Description Cat. # (Sold Separately) Bolt-on visor (sold separately).................... Bolt-on wire guard (sold separately).................... Floodlight slipfitter (sold separately).................... Slipfitter wall mount adapter (sold separately).................... DSV1 P61 SFA6* SWB6* *Available with PFM25L model only. Drivers: PFM Model /UNV1 /UNV34 25L, 50L 90-305 VAC, 50 / 60 Hz; 127-250 VDC 277-480 VAC Model Electrical Ratings: • • • • • UL1598 UL1598A cUL NEMA 4X; IP66 DesignLights Consortium® approved for select models (refer to Ordering Information for details) • UL approved up to 40°C ambient PFM25L PFM50L 120-277V 50 / 60 Hz Voltage Range, VAC 277-480V 50 / 60 Hz Voltage Range, VDC 127-250V Input Power (Nom.) 263 531 Input Amps (Max.) 2.6 5.2 Power Factor >0.90 Ordering Information: 25L Series†* 50L Series PFM25LCY/UNV1 76 PFM50LCY/UNV1 76 NOTE: Available in cool color temperature only. For 277-480 VAC option, replace /UNV1 with /UNV34. †DesignLights Consortium® approved model at 120-277V. *PFM25L is DLC approved with a 5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard terms and conditions. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 949 2L • High lumen output for installation in high mounting heights • Locations requiring continuous and consistent light levels • Areas requiring frequent on-and-off of lights • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist; indoors or outdoors • NEMA 4X, marine, wet locations, and hose-down environments • Indoor and outdoor area lighting in plants, buildings, and parking areas • Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; platforms; loading docks; outdoor mounted general area lighting • Ball mills, stackers and reclaimers, concentrators, smelters, mine roadways, outdoor processing areas, truck service shops, shovels, and drag lines Options: 950-951.qxp 12/16/2013 2L 7:41 PM Page 950 Champ® Pro PFM Series 25L and 50L LED Floodlights UL/cUL Listed NEMA 4X IP66 High efficiency and lumen output The heat sink was designed to perform in high ambient temperatures up to +40ºC and as low as -25ºC. The thick walls of the castings make for a tough, rugged housing that keeps the internal driver and LED temperatures down, allowing them to perform flawlessly, and protects them from damage. Separated driver and LED housing allows dust to shed from fixture. High efficiency drivers and LEDs provide 100 LPW for reliable low cost operation in industrial environments. Components were chosen to give industry-leading light output from an LED flood. Replaceable drivers and LEDs for ease of maintenance and “no lights out” feature. 2L Safe, reliable heat transfer Versatile design Can be used for outdoor or indoor applications, and for a wide range of mounting heights depending on model and light level requirement. Optics were specifically designed to give the familiar and industry-accepted NEMA 7x6 beam light pattern. 950 www.crouse-hinds.com US: 1-866-764-5454 Optional equipment (sold separately) Optional visor offered to control light spill. Optional wire guard offered to protect lens from damage. Other options available - consult part numbering guide. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 950-951.qxp 12/16/2013 7:41 PM Page 951 Champ® Pro PFM Series 25L and 50L LED Floodlights UL/cUL Listed NEMA 4X IP66 2L Dimensions: 532.9 21.0 277 10.9 552.5 21.75 234.5 9.2 203.7 8.0 405.9 16.0 525.6 20.7 120.7 4.75 .55 PFM25L Model 277 10.90 556.3 21.90 254 10.00 235.8 9.28 532.9 20.98 203.7 8.02 13.9 Ø .55 127 5.00 825 32.48 632.6 24.90 PFM50L Model Photometric Data: 200 175 150 125 100 75 50 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.6 0.7 0.7 0.7 0.8 0.7 0.7 0.7 0.6 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.5 0.6 0.7 0.8 0.9 0.9 0.9 0.9 0.9 0.8 0.7 0.6 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.8 0.9 1.0 1.1 1.2 1.2 1.2 1.1 1.0 0.9 0.8 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.7 0.7 0.8 0.7 0.7 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.6 0.7 0.9 1.1 1.3 1.5 1.6 1.6 1.6 1.5 1.3 1.1 0.9 0.7 0.6 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.8 0.9 1.0 1.0 1.0 0.9 0.8 0.7 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.6 0.8 1.1 1.4 1.7 1.9 2.1 2.1 2.1 1.9 1.7 1.4 1.1 0.8 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.6 0.8 1.1 1.2 0.1 0.2 0.3 0.4 0.5 0.7 0.9 1.3 2.8 2.9 2.8 2.2 1.7 1.3 0.9 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.4 0.5 0.7 1.0 1.3 1.6 0.1 0.2 0.3 0.4 0.5 0.7 1.0 1.5 2.0 2.7 3.3 3.7 3.9 3.7 3.3 2.7 2.0 1.5 1.0 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.2 0.2 0.4 0.5 0.8 1.1 1.7 2.4 3.4 4.3 5.0 5.1 5.0 4.3 3.4 2.4 1.7 1.1 0.8 0.5 0.4 0.2 0.2 0.1 0.2 0.2 0.4 0.6 0.9 1.3 2.1 3.2 4.6 6.3 7.4 7.9 7.4 6.3 4.6 3.2 2.1 1.3 0.9 0.6 0.4 0.2 0.2 0.1 0.1 0.2 0.3 0.4 0.7 1.1 1.5 1.9 3.0 6.5 8.0 8.5 8.0 6.5 4.5 3.0 1.9 1.1 0.7 0.4 0.3 0.2 0.1 0.1 1.3 1.4 1.3 1.2 1.1 0.8 0.6 0.5 0.3 0.2 0.2 0.1 0.1 0.1 1.8 1.9 1.8 1.6 1.3 1.0 0.7 0.5 0.4 0.2 0.2 0.1 0.1 0.1 175 150 125 100 75 50 2 25 0 0.1 0.1 0.1 0.2 0.3 0.4 0.1 0.1 0.1 0.2 0.3 0.0 0.1 0.1 0.1 0.2 .1 .5 1.7 2.1 2.4 2.5 2.4 2.1 1.7 1.2 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 1.6 2.3 3.1 3.7 3.9 3.7 3.1 2.3 1.6 1.0 0.7 0.4 0.3 0.2 0.1 0.1 0.1 1.5 2.2 3.1 3.8 3.8 3.1 2.2 1.5 0.9 0.6 0.3 0.2 0.1 0.1 0.1 0.0 0.6 0.8 1.2 0.4 0.7 1.0 0.3 0.6 0.9 .25 1 1.5 3 4 4.1 25 0.1 0 0.25 0.15 0.5 1 Point By Point Foot-Candle Readings -125 -100 -75 -50 -25 0 25 1.7 2.2 2 4 4.5 0.25 0.50 1.00 1.50 3 5 2.6 PFM Model Lbs. PFM25L PFM50L 52.00 106.00 0.2 0.1 Point By Point Foot-Candle Readings 50 75 100 125 -125 -100 -75 -50 Distance In Feet 0.10 2.6 2L Weights: PFM50L @ 50 Ft. High PFM25L @ 50 Ft. High 200 -25 0 25 75 50 100 125 Distance In Feet 2.00 3.00 4.00 0.15 0.25 0.50 1.00 1.50 2.00 3.00 4.00 5.00 Footcandles Footcandles Luminaire Series Wattage Lumens Luminaire Series Wattage Lumens PFM25L 263 26,240 PFM50L 531 53,890 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 951 952-953.qxp 12/16/2013 7:16 PM Page 952 Vaporgard™ Pro P2L Series Luminaires 2L UL/cUL Listed NEMA 4X IP66 For targeted illumination in low mounting height areas Standard Materials: The Vaporgard™ Pro P2L Family P2LC/UNV1 - Cool White Color Temperature The P2LC/UNV1 Luminaire provides uniform crisp, white light and is suitable for lower mounting heights, confined spaces, tunnels, or utility rooms. Using four high power, high brightness LED arrays, this fixture can deliver similar light levels to 150 watt incandescent. P2LW/UNV1 - Warm White Color Temperature The P2LW/UNV1 Luminaire provides similar benefits as the cool white version, but with a color rendering more consistent with a warm incandescent or HPS lamp source. Perfect for situations where Vaporgard Pro will be installed next to a warmer color light source. DC Power Supply - Available for Applications Requiring DC Power For applications with DC power requirements such as solar or back-up battery. The DC power supply is suitable for 12VDC through 24VDC. Certifications and Compliances: • • • • • UL1598 UL1598A cUL NEMA 4X; IP66 DesignLights Consortium® approved for select models (refer to Ordering Information for details) 2L Electrical Ratings: Voltage Input Power (Watts) Input Current Power Factor THD (I) (%) Maintained Lumens Efficacy, LPW Color Temperature • Body and mounting modules – copper-free aluminum with Corro-free™ epoxy powder coat • Lens bezel – aluminum with anodized finish • Lens – heat- and impact-resistant glass • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required LED Array: • • • • (4) High brightness LED arrays Cool white (5600K), CRI 65 Warm white (3000K), CRI 82 70% lumen maintenance (L70) at 50K hours LED Driver: • • • • • • • • Constant current regulated power supply 90VAC - 264VAC, 277VAC, 50 / 60 Hz Internal fusing Active power factor correction, >0.9 Low harmonic distortion, <20% Low inrush current, <20 amps EMC compliant to 47CFR, Part 2, Part 15 12VDC / 24VDC option available Series P2LC/UNV1* P2LW/UNV1 P2LC/DC1 P2LW/DC1 90-264VAC, 277VAC 22 0.23 / 0.10 >0.9 <20% 1633 64 5600K 90-264VAC, 277VAC 22 0.23 / 0.10 >0.9 <20% 1400 56 3000K 12-24VDC 22 2.1 / 1.0 N/A N/A 1633 64 5600K 12-24VDC 22 2.1 / 1.0 N/A N/A 1400 56 3000K *5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium approved models. Ordering Information: Cool White Warm White Mounting Style AC Drive** DC Drive AC Drive DC Drive /2" Pendant P2LCA1/UNV1** P2LCA1/DC1 P2LWA1/UNV1 P2LWA1/DC1 1 3 /4" Pendant P2LCA2/UNV1** P2LCA2/DC1 P2LWA2/UNV1 P2LWA2/DC1 1" Pendant P2LCA3/UNV1** P2LCA3/DC1 P2LWA3/UNV1 P2LWA3/DC1 /2" Wall with Junction Box P2LCHBF1/UNV1** P2LCHBF1/DC1 P2LWHBF1/UNV1 P2LWHBF1/DC1 /4" Wall with Junction Box P2LCHBF2/UNV1** P2LCHBF2/DC1 P2LWHBF2/UNV1 P2LWHBF2/DC1 /2" Ceiling P2LCHF1/UNV1** P2LCHF1/DC1 P2LWHF1/UNV1 P2LWHF1/DC1 /4" Ceiling P2LCHF2/UNV1** P2LCHF2/DC1 P2LWHF2/UNV1 P2LWHF2/DC1 /2" VXT Wall P2LCHT1/UNV1** P2LCHT1/DC1 P2LWHT1/UNV1 P2LWHT1/DC1 /4" VXT Wall P2LCHT2/UNV1** P2LCHT2/DC1 P2LWHT2/UNV1 P2LWHT2/DC1 P2LWHW1/DC1 1 3 1 3 1 3 /2" VXW Wall P2LCHW1/UNV1** P2LCHW1/DC1 P2LWHW1/UNV1 3 /4" VXW Wall P2LCHW2/UNV1** P2LCHW2/DC1 P2LWHW2/UNV1 P2LWHW2/DC1 11/4" Stanchion P2LCHJ4/UNV1** P2LCHJ4/DC1 P2LWHJ4/UNV1 P2LWHJ4/DC1 Adapter Only* P2LCHR/UNV1** P2LCHR/DC1 P2LWHR/UNV1 P2LWHR/DC1 1 *For use when wall mount or ceiling mount box is already installed. **5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium approved models. Cool white only. 952 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 952-953.qxp 12/16/2013 7:16 PM Page 953 Vaporgard™ Pro P2L Series Luminaires 2L UL/cUL Listed NEMA 4X IP66 For targeted illumination in low mounting height areas Options: Accessories (Order Separately): Description Frosted lens reduces glare in applications where the user may have direct visual contact with the light source . . . . . . . . . . . . Teflon coating on lens provides additional shatter protection for applications in food and beverage facilities . . . . . . . . . . . . . High temperature option allows operation up to 55°C ambient temperature (AC unit only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Suffix S891 S896 S902 Description Cat. No. Sold Separately Magnet bracket only (available for ceiling mount VXF20 only) . . . . . . . . . . . . . . . . . . P2L Magbrk Magnet bracket kit (includes ceiling mount) . . . . . . . . . P2L Magbrk K1 Dimensions: Pendant Wall 11 1/4 [285.1] 8 3/4 [221.7] Ceiling Stanchion 8 3/4 [221.7] 6 7/8 [175] 11 13/16 [299.9] 15/16 [23.9] 3/4" NPT HUB 1/2" REDUCER SUPPLIED Ø4 9/16 [Ø116.0] Ø1/4 [Ø7.1] 4 3/4 [121.3] 3 7/8 [99] 8 1/8 [206.7] 1-1/4" HUB 45° 5 1/2” NPT OR 3/4" NPT HUB 8 3/4 [221.7] 4 1/2 [114.7] 4 11/16 [119.8] 3 7/8 [99.2] VLA1 1/2" NPT HUB VLA2 3/4" NPT HUB VLA3 1" NPT HUB 5 7/8 [149.1] 1 3/4 [44] 3 7/8 [98.5] 2 1/8 [53.4] 5 3/4 [146.2] 1 [25.4] 1/4 [5.6] 1 [25.4] 2 1/8 [53.9] Ø4 15/16 [125.2] 1 3/4 [44] 1 3/4 [44] 7 1/16 1 [179.7] [25.4] 1 [25.4] 8 3/4 [221.7] 1 3/4 [44] Family Tree: 2L VXF 10 VXFT 10 VXF 20 VXFT20 VXJ4 VXW2 VLA1 VLA2 VLA3 VXT20 VXF 10 VXFT 10 VXF 20 VXFT20 VLHR P2L LED Housing VAPORGARD P2L SERIES Complete luminaire consists of LED Housing and Cover: a VLA pendant, or a VLHR adapter and VX series mounting module shown. Weights: Ambient Temperature: Luminaire & Mounting Module Weight Pendant Mount Ceiling Mount Wall Mount Stanchion Mount Lbs. 5.7 6.8 7.9 6.5 www.crouse-hinds.com Vaporgard™ Pro P2L Model P2L/UNV1 US: 1-866-764-5454 Max. Temp. °C 40 P2L/UNV1 S902 55 P2L/DC1 40 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 953 954-955.qxp 12/16/2013 7:16 PM Page 954 Vaporgard™ Pro P2L Series Luminaires 2L UL/cUL Listed NEMA 4X IP66 For targeted illumination in low mounting height areas Photometric Data: Vaporgard™ Pro LED (22 Watt) DISTANCE TO MOUNTING HEIGHT Isofootcandle chart shows illuminance in foot-candles at ground level 3 CANDLEPOWER DISTRIBUTION (IN CANDELAS) 2 1 0 -1 -2 1000 -3 1500 -3 -2 -1 0 1 2 3 2000 ISOFOOTCANDLE CHART 2500 Footcandle Values for Isofootcandle Lines 3000 3500 A 4000 B C D E F 4500 5000 2L 5500 ZONAL LUMENS 954 ZONE LUMENS % LUMEN 0-30 468 28.65 0-40 772 47.30 0-60 1374 84.15 0-90 1633 100.00 40-90 860 52.70 60-90 259 15.85 90-180 0 0.00 0-180 1633 100.00 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Mtg. Hgt. A B C D E F 6’ 10.00 5.00 2.00 1.00 0.50 0.20 8’ 5.62 2.81 1.13 0.56 0.28 0.11 10’ 3.60 1.80 0.72 0.36 0.18 0.07 12’ 2.50 1.25 0.50 0.25 0.13 0.05 14’ 1.84 0.92 0.37 0.18 0.09 0.04 Copyright© 2013 Eaton’s Crouse-Hinds Business 954-955.qxp 12/16/2013 7:16 PM Page 955 Meets UL1598/cUL construction requirements* Industrial High Bay LED Series Luminaires Applications: Electrical Ratings: • Locations requiring continuous and consistent light levels • Areas requiring frequent on-and-off of lights • Areas that are difficult to relamp or that cause production to be stopped during the lamp maintenance process • Ordinary clean, light industrial production facilities, packaging facilities, and warehouses • Indoor and dry locations only • 100 VAC to 277 VAC 50 / 60 Hz • 347 VAC to 480 VAC 50 / 60 Hz Features: • Up to 69% energy savings over 400W metal halide fixtures • 60,000 hours (rated life) of maintenancefree operation for labor and material savings over the life of the fixture • Two to three year payback by retrofitting four or six lamp T5HO or 400W metal halide high bay fixtures • Operating temperature of -30°C to +40°C ambient • Uniform wide distribution for optimum lighting levels for 18-25 foot mounting heights • Occupancy sensing control available for enhanced energy savings and lifetime of LED fixture • Hook and cord attachment for 3/ 4" pendant hub • 347-480 VAC driver option Certifications and Compliances: *Not UL Listed. **For /UNV1 model. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's CrouseHinds standard Terms and Conditions. P.F. THD Amps 120 277 0.995 0.950 8.16% 12.3% 1.178 0.524 Ordering Information: Cat. # IHB13L2A/UNV1 Note: Description Industrial High Bay, 13,940 Lumens, 3/ 4" Pendant Mount, 100-277 VAC Accessories: For 347-480 VAC, replace /UNV1 with /UNV34. Description Cat. # (Sold Separately) Occupancy sensor kit, 3 / 4" entry (sold separately) .........IOS2/UNV1‡ Hook and cord kit (sold separately) ........................IHB HC KIT Driver replacement kit IHB PS/ (sold separately) ........................ UNV1 KIT Options: Description Suffix Hook and cord attachment for 3/ 4" pendant hub ...................... HC ‡For 347-480 VAC, replace /UNV1 with /UNV34. Specifications: Key Specifications Lumens (Typical)† 13,940 Wattage 141W (at 120 VAC); 138W (at 277 VAC) Lumens Per Watt (LPW) 99 Color Temperature 5,000K CRI >70 Voltage Range (VAC) 100-277V, 347-480V; 50 / 60 Hz Power Factor 0.95 at 277 VAC Total Harmonic Distortion 12.3% at 277 VAC Operating Temperature -30°C to +40°C Lifetime 60,000 hours at +40°C Warranty 5 years** 2L • Meets UL1598 and cUL construction requirements* • DesignLights Consortium®** Voltage 2L †Tolerance +/- 10%. **For /UNV1 model. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. Dimensions: 445 17.5 237 9.3 363 14.3 153 6.0 134 5.3 82 3.2 70 2.8 www.crouse-hinds.com 3/4"-14 CONDUIT CONNECTION 208 8.2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 955 956-957.qxp 12/16/2013 7:16 PM Page 956 Endure™ LED Wall Pack 2L UL/cUL Listed IP66 For mining and heavy industrial applications Endure™ LED Wall Pack Family Standard Materials: Model Equivalent HID Output Energy Savings • Housing – 16 gauge stainless steel (SS201), painted powder coat white; optional 316 stainless steel housing available for extreme corrosion resistance • Door – die-formed stainless steel with 0.156" thick clear tempered glass lens; 316 stainless steel (optional) • Gasket – silicone, around perimeter of glass • Screws – stainless steel FM1 B01 FM1 B02 50W HPS 70W HPS/MH 59% 43% Standard Finish: The IP66, stainless steel Endure™ LED Luminaire features the patented, modular LED LightBAR™ technology. The Endure LED Luminaire is available with one or two LightBAR configurations in Type II or Type V distributions. Applications: • Ideal for a variety of non-hazardous applications such as mining, food processing, marine, wastewater treatment, heavy manufacturing, and general wash-down areas E D B C A • All external components are finished in a polyester white powder coat paint, electrostatically applied Design Features: A White light - provides superior color rendering and ambient clarity. Optics are precisely designed to shape the distribution, maximizing efficiency and application spacing. B Energy efficiency and longer life – 50,000 hours rated life and up to 59% more energy- Certifications and Compliances: efficient than the 70W high pressure sodium equivalent. C Reduction in light pollution – controlled distribution of light means far less light loss. D IP66 ingress protection rating and -30°C to 50°C ambient temperature rating – ensures • UL1598 • cUL • IP66 trouble-free operation in a variety of harsh and complex applications. E Junction box – polycarbonate, IP66 rated, four screws to access cover, double row terminal box to expedite installation. 2L LED System: • Choice of Type II or Type V high efficiency AccuLED™ optics designed to shape light distribution for maximizing efficiency and application spacing • 50,000+ hour life with >70% lumen maintenance • 4000K (± 275) CCT and nominal 70 CRI • 98 lumens per watt; 0.9 power factor Electrical Ratings: Distribution No. of LightBARs Power (Watts) Current @ 120V(A)* 1 27 0.23 2 51 0.43 Current @ 277V(A)* Lumens (Type II) Lumens (Type V) 0.13 2304 2382 0.20 4571 4726 21 LED LightBAR *Proprietary circuit module designed to withstand 10kV of transient voltage surge. Ordering Information: PRODUCT FAMILY NO. OF LIGHTBARS LAMP TYPE FM1 B01 LED ELECTRICAL DISTRIBUTION E1 T2 Product Family Finish FM1 WH BK BZ Endure Luminaire No. of LightBARs B01 B02 (1) 21 LED LightBAR (2) 21 LED LightBARs FM1-EBP-WH Solid State Light Emitting Diodes Electrical E1 FINISH ACCESSORIES OPTIONS CTG156 WH FM1-EBP-WH 316SS White Powder Coated Paint Black Powder Coated Paint Bronze Powder Coated Paint Accessories Lamp Type LED LENS Electronic Driver (1) (120-277V) Distribution Options T2 5MQ 316SS Type II Type V EM Battery Pack Unit (Coming Soon) Same dimensions as non-EM unit but with full stainless steel door. Replace ‘WH’ in the catalog number with ‘BK’ or ‘BZ’ for black or bronze finish. Includes test switch and indicator light. Type 316 Stainless Steel Housing and Door Lens CTG156 Clear Tempered Glass, 0.156” Thick PC125 Clear Polycarbonate, 0.125” Thick AC125 Clear Acrylic, 0.125” Thick 956 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 956-957.qxp 12/16/2013 7:16 PM Page 957 Endure™ LED Wall Pack 2L UL/cUL Listed IP66 For mining and heavy industrial applications Dimensions: Top View (2 LightBAR Configuration Shown) End View 8.5” [215.1mm] 8.5” [215.1mm] 3.7” [94mm2] 10” [254mm] 5.75” [145.9mm] 13.7” [348mm] 17.1” [434mm] 10” [254mm] Side View Mounting 17.1” [434mm] 13.7” [348mm] 8” [200mm] 5.7” [146mm] 7” [178mm] Photometric Data: Type II Distribution 3877 3182 2908 2386 1939 1591 969 795 H V 2L V Type V Distribution H Lumen Multiplier (2 Bar) Temperature Multiplier Lumens 10°C 15°C 25°C 40°C 50°C 1.09 1.03 1.00 0.96 0.92 5151 4868 4726 4537 4348 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 957 958-959.qxp 12/16/2013 7:16 PM Page 958 2L 2L 958 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 958-959.qxp 12/16/2013 7:16 PM Page 959 3L High Intensity Discharge (H.I.D.) Lighting Hazardous and Non-hazardous Description Page No. Application/Selection see page 960 Champ Series – Integrally Ballasted Luminaires ® Accessories Ballast Data (USA) Ballast Data (Canada) see pages 1022–1023 see page 874 see page 874 VMV Series 50 – 175W H.I.D Catalog Listings Temperature Data, Dimensions, Weights Photometric Data LMV Series 50 – 150W H.I.D Catalog Listings Temperature Data, Dimensions, Weights Photometric Data DMV Series 50 – 250W H.I.D. Catalog Listings Temperature Data, Dimensions, Weights Photometric Data VMV High Wattage Series 200 – 400W H.I.D. Catalog Listings Temperature Data, Dimensions, Weights Photometric Data see page 962 see page 963 see page 968 see pages 970–971 see see see see page page page page 972 973 977 979 see see see see page page page page 980 981 986 988 see see see see page page page page 989 990 995 997 VMVIG Series Induction Lighting see pages 998–1004 DMVIG Series Induction Lighting see pages 998–1004 N2MV Non-metallic H.I.D. nVMV Ex-Protected Luminaire for IEC and ATEX Applications Catalog Listings Temperature Data, Dimensions, Weights Photometric Data Photocells www.crouse-hinds.com US: 1-866-764-5454 see see see see page page page page 1005 1006 1011 1013 see page 1014 see page 1015 see page 1016 see pages 1018–1021 see page 1024 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 959 3L Catalog Listings Temperature Data, Dimensions, Weights Photometric Data 960-961.qxp 12/16/2013 7:17 PM Page 960 H.I.D. (High Intensity Discharge) Luminaires 3L Enclosed & Gasketed Application and Selection Applications: Luminaires included in this section are enclosed and gasketed, designed for use with H.I.D. lamps as follows: • In locations where protection is required from wet, dirty and corrosive atmospheres • Where long life lamps provide desirable maintenance cost savings and return on investment through use of fewer luminaires, circuits and ancillary apparatus • Where relamping and maintenance difficulties require long life lamps Considerations for Selection: Environmental: • What are the hazardous areas classifications (NEC/CEC) of the locations in which the luminaires will be installed? • Must luminaires be suitable for use in marine, hosedown, corrosive applications? Lighting levels required: • What wattage luminaire(s) will provide the desired light level? Quick Selector Chart* Series Watts HPS, MH & Pulse Start MH Lamps Champ VMV 50, 70, 100, 150, 175 Mogul Base Hazardous Area & Other Enviromental Suitabilities NEC, CEC, IEC NEC & CEC Champ VMV High Wattage Cl. I, Div. 2 Groups A, B, C, D Cl. II, Groups E, F, G Cl. III Simultaneous Presence 200, 250, 400 Mogul Base Ballast Voltages Standard Voltage Ballasts (60 Hz) NEC (UL) Multi-tap: 120, 208, 240 & 277 Volt 60 Hz. Dual-tap: 120 & 277 Volt 60 Hz (50W HPS) 120 Volt 60 Hz 480 Volt 60 Hz 3L CEC/CSA (cUL) Tri-tap: 120, 277 & 347 Volt 60 Hz Restricted Breathing (Suffix – S826) Cl. I, Div. 2 & Zone 2 AEx nR, Ex nR IIC Dual-tap: 120 & 277 Volt 60 Hz (50W HPS) 120 Volt 60 Hz Marine Outdoor & Wet Locations Champ LMV Low Profile 50, 70, 100, 150 Medium Base Champ DMV Expanded Class II Suitability 50, 70, 100, 150, 175, 250 Mogul Base Champ N2MV Non-metallic 50, 70, 100, 150, 175 Mogul Base Optional Voltage Ballasts (50 or 60 Hz) Type 3, 3R, 4, 4X IP56 to IP66 IEC Certified for IEC Zone 2 (Suffix – S826TB) Ex nR IIC 208 240 480 600 IP56 to IP66 Zone 2 according to IEC Ex nR II T...Gc Champ nVMV Ex-Protected Luminaire for IEC and ATEX Applications 70 Medium 100, 150 Medium & Mogul 250, 400 Mogul Zone 21 and 22 according to IEC Ex t IIIC T...ºC Db IP66 IP66 ATEX *See specific sections for lamp type and wattage suitability. 960 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business CEC/CSA (cUL) Volt 60 Hz CWI – Isolated Volt 60 Hz CWI – Isolated Volt 60 Hz CWI – Isolated Volt 60 Hz CWI – Isolated EXPORT 220 Volt 50 Hz 230 Volt 50 Hz 240 Volt 50 Hz 220 Volt 50 Hz 230 Volt 50 Hz 240 Volt 50 Hz 220 Volt 60 Hz 230 Volt 60 Hz 240 Volt 60 Hz 960-961.qxp 12/16/2013 7:17 PM Page 961 Champ® H.I.D. Luminaires VMV, LMV, DMV, VMV High Wattage, N2MV & nVMV Series Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G, Cl. III Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP56 to IP66 3L The Champ family is an extremely versatile industrial lighting system. Six different series of Champ Luminaires embrace a broad range of wattages, lamp sources, compliances, optics, and accessories. Each series is covered in detail on the following pages. General information to help in the proper selection of series and luminaires is shown below. Applications: Heavy duty Champ lighting luminaires are used: • In manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore, dockside, and harbor installations, and other heavy industrial applications • In areas where ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions • Where combustible dusts are present • In marine applications where water spray and corrosive atmospheres are considerations • In elevated ambient temperatures often found in industrial applications • In installations where moisture, dirt, dust, vibration, corrosion, and rough usage are problems • Wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements are found Features: 3L • Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion. • Seven mounting arrangements in each series, to suit any lighting layout – pendant, flexible pendant, ceiling, wall bracket, angle stanchion, straight stanchion, and quadmount. • Wide range of light sources and wattages to meet specifiers' needs: 50, 70, 100, 150, 200, 250 and 400 watt high pressure sodium (HPS); 70, 100 175, 250, and 400 watt metal halide (MH and Pulse Start MH). • Hinged ballast housings for ease of installation and maintenance; all mounting modules fit all ballast housings. • Wide choice of photometric distributions. Globes available for lamps up through 400 watt HPS, and 250 watt MH. Glass refractors available for all VMV and DMV units; reflector/lens for 200–400 watt VMV units. • All luminaires are designed to perform in a 40°C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. • Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. • Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation. • Low ambient capability to –40°C. • Dome and 30° angle reflectors made of bright white Krydon® fiberglassreinforced polyester material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode. • Grounding wire for safety. • Ballasts are high power factor (min P.F. 90%) and available in a variety of voltages to meet local area requirements. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 961 962-963.qxp 12/16/2013 3L 7:17 PM Page 962 VMV Series 50–175W Champ® H.I.D. Luminaires Applications: Options: VMV series Champ luminaires are used: • In manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore, dockside, and harbor installations, and other heavy industrial applications • In areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions • Where combustible dusts are present • In marine applications where water spray and corrosive atmospheres are considerations • In elevated ambient temperatures often found in industrial applications • In installations where moisture, dirt, dust, vibration, corrosion, and rough usage are problems • Wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements are found The following special options are available from the factory by adding suffix to luminaire Cat. No.: Description Suffix Factory Sealed Champs . . . . . . . . . . .S865 Class I, Division 2 & Zone 2 Provides T3 code without conduit or cable seals Restricted breathing/Non-sparking Restricted Breathing Construction . . .S826 Class I, Division 2 & Zone 2 Suitabilty Cooler Operating Temperatures (T-Numbers) Certified for IEC Zone 2 . . . . . . . . . . .S826TB Furnished with terminal block, crimp terminals and dedicated voltage ballasts (no MT, DT or TT) Fused – to protect ballast and capacitors against abnormal line conditions . . . . . . . . . . . . . . . . . . . . . .S658* (Not available with /MT Ballast) (Not for use in Canada) (Not suitable for marine applications) Quick-Clip - Holds weight of housing when closed. No need to support luminaire while screwing the housing to the cover . . . . . . . . . . . . . .S890 Ballast-Gard™ starter cut-out switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50–150W LX HPS only . . . . . . . . . . . .BG Instant restrike – enables a hot HPS lamp to immediately restrike after a momentary loss arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. 50–150W LX HPS only . . . . . . . . . . IR 50–100W LX HPS only . . . . . . . . . . TIR Quartz auxiliary lighting – comes to full brightness immediately and remains lit until the HID lamp attains 60–70% of full illumination. For nonhazardous locations only. Must use R2, R3 and R5 refractors. . . . . . . . . . . . . . . . . . . . .QTZ Refractor Mount - For ballast housing only. Used with R2, R3 and R5 refractors. . . . . . . . . . . . . . . . . . . . .RM Stainless steel insert – top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . . .S806 TEFLON coating on globe for increased shatter protection . . . . . . . .S808 G24 only. T-Numbers not affected Factory assembled with H.I.D. lamps installed for additional labor savings . . . . . . . . . . . . . . . . . . . . . . . .FA Features: 3L Cl. II, Groups E, F, G, Cl. III & Simultaneous Presence (HPS 50W, 70W) Marine & Wet Locations 3, 3R, 4, 4X; IP56 to IP66 Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) • Compact, lightweight design is ideal for medium and low mounting heights • Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion • Seven mounting arrangements to suit any lighting layout – pendant, flexible pendant, ceiling, wall bracket, angle stanchion, straight stanchion, and quad-mount • Wide range of light sources and wattages to meet specifiers' needs: 50, 70, 100, and 150 watt high pressure sodium (HPS); 70, 100, 175 watt metal halide (MH and Pulse Start MH) • Hinged ballast housing for ease of installation and maintenance • Wide choice of photometric distributions. Glass globes, refractors and compact refractors available for all wattage luminaires; plastic refractors (for nonhazardous applications only) for 50–100 watt luminaires • All luminaires are designed to perform in a 40°C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C • Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments • Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation • Low ambient capability to (–40°C) • Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode • Grounding wire for safety • High power factor ballasts (Min P.F. 90%) and available in a variety of voltages to meet local area requirements • Mogul base porcelain lamp socket 962 www.crouse-hinds.com US: 1-866-764-5454 Certifications and Compliances: • NEC & CEC: Class I, Division 2, Groups A, B, C, D HPS 50W, 70W – Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 • IEC: Zone 2 Ex nR IIC • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 Standard Materials: • Ballast housings and mountings – copper-free aluminum (less than 0.4 of 1%) • Exterior hardware – stainless steel • Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material • Globes – heat and impact resistant internally fluted glass • Refractors – glass (50–175 watts); plastic 50–100 watts), for non-hazardous applications • Guards: Globe – copper-free aluminum Refractor – stainless steel Standard Finishes: • Copper-free aluminum – epoxy powder coat • Krydon material – high reflectance white • Stainless steel – natural Note: BG and IR options cannot be used together. IR and QTZ options cannot be used together. Accessories: Electrical Ratings: • See pages 1022–1023 for complete listing. • 120, 208, 240, 277, 347, 480, 600, Multitap (120, 208, 240 and 277) • 50 to 150W HPS; 70 to 175W MH TEFLON is a registered trademark of E.I. duPont Co. CAN: 1-800-265-0502 *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Copyright© 2013 Eaton’s Crouse-Hinds Business 962-963.qxp 12/16/2013 7:17 PM Page 963 VMV Series 50–150W High Pressure Sodium Champ® H.I.D. Luminaires Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G, Cl. III & Simultaneous Presence (50W, 70W) Marine & Wet Locations 3, 3R, 4, 4X; IP66 3L To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Hub Lamp With G24 Globe With G241 Type I With R5 Glass Style Size Watts and P21 Guard Compact Refractor * Refractor † 50 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 50 Stanchion Mount 25° Angle Stanchion Mount Straight Flexible Pendant Mount Ceiling Mount Thru-Feed Wall Mount Thru-Feed Quad-Mount Pendant, Adjustable, Thru-Feed, 25º Angle, 12½º Angle VMVS2A050GP VMVS3A050GP VMVS2A070GP VMVS3A070GP VMVS2A100GP VMVS3A100GP VMVS2A150GP VMVS3A150GP VMVS2HA050GP VMVS2HA070GP VMVS2HA100GP VMVS2HA150GP VMVS2A050G241 VMVS3A050G241 VMVS2A070G241 VMVS3A070G241 VMVS2A100G241 VMVS3A100G241 VMVS2A150G241 VMVS3A150G241 VMVS2HA050G241 VMVS2HA070G241 VMVS2HA100G241 VMVS2HA150G241 VMVS2A050R5 VMVS3A050R5 VMVS2A070R5 VMVS3A070R5 VMVS2A100R5 VMVS3A100R5 VMVS2A150R5 VMVS3A150R5 VMVS2HA050R5 VMVS2HA070R5 VMVS2HA100R5 VMVS2HA150R5 50 70 100 150 VMVS2C050GP VMVS3C050GP VMVS2C070GP VMVS3C070GP VMVS2C100GP VMVS3C100GP VMVS2C150GP VMVS3C150GP VMVS2TW050GP VMVS3TW050GP VMVS2TW070GP VMVS3TW070GP VMVS2TW100GP VMVS3TW100GP VMVS2TW150GP VMVS3TW150GP VMVS25Q050GP VMVS25Q070GP VMVS25Q100GP VMVS25Q150GP VMVS2C050G241 VMVS3C050G241 VMVS2C070G241 VMVS3C070G241 VMVS2C100G241 VMVS3C100G241 VMVS2C150G241 VMVS3C150G241 VMVS2TW050G241 VMVS3TW050G241 VMVS2TW070G241 VMVS3TW070G241 VMVS2TW100G241 VMVS3TW100G241 VMVS2TW150G241 VMVS3TW150G241 VMVS25Q050G241 VMVS25Q070G241 VMVS25Q100G241 VMVS25Q150G241 VMVS2C050R5 VMVS3C050R5 VMVS2C070R5 VMVS3C070R5 VMVS2C100R5 VMVS3C100R5 VMVS2C150R5 VMVS3C150R5 VMVS2TW050R5 VMVS3TW050R5 VMVS2TW070R5 VMVS3TW070R5 VMVS2TW100R5 VMVS3TW100R5 VMVS2TW150R5 VMVS3TW150R5 VMVS25Q050R5 VMVS25Q070R5 VMVS25Q100R5 VMVS25Q150R5 11/2 11/2 11/2 11/2 50 70 100 150 VMVSJ050GP VMVSJ070GP VMVSJ100GP VMVSJ150GP VMVSJ050G241 VMVSJ070G241 VMVSJ100G241 VMVSJ150G241 VMVSJ050R5 VMVSJ070R5 VMVSJ100R5 VMVSJ150R5 11/2 11/2 11/2 11/2 50 70 100 150 VMVSP050GP VMVSP070GP VMVSP100GP VMVSP150GP VMVSP050G241 VMVSP070G241 VMVSP100G241 VMVSP150G241 VMVSP050R5 VMVSP070R5 VMVSP100R5 VMVSP150R5 70 100 150 50 70 100 150 70 100 150 50 70 100 150 3L 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 Pendant Mount * For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVS2A050G243 For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVS2A050G245 † For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVS2A050R2. For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVS2A050R3. 2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps - add suffix CE. 50W HPS luminaire is dual tap only. 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL CEC/CSA (cUL) Voltage Multi Tap Dual Tap 120V Suffix /MT /DT /120 Multi Tap and Dual Tap ballasts are powered for 277V 480V /480 Tri Tap /TT Dual Tap /DT 600V CWI /600CWI 220V 60Hz /220 220V 50Hz /220 50 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI www.crouse-hinds.com 120V /120 3. Options - Add the required option suffixes, see page 962, in alpha-numeric order. EXPORT US: 1-866-764-5454 240V 50Hz /240 50 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 963 964-965.qxp 12/16/2013 3L 7:18 PM Page 964 VMV Series 150–175W Pulse Start Metal Halide Marine & Wet Locations 3, 3R, 4, 4X; IP66 Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Champ® H.I.D. Luminaires To complete the catalog #, include information in note 1 below. For guards and other optics see VMV Series - Ordering By Components page. Mounting Style Hub Size Lamp Watts With G24 Globe and P21 Guard Pendant Mount 3 /4 1 3 /4 1 150 VMVM2A150GP VMVM3A150GP VMVM2A175GP VMVM3A175GP S828 S828 S828 S828 VMVM2A150G245 VMVM3A150G245 VMVM2A175G245 VMVM3A175G245 S828 S828 S828 S828 /4 /4 150 175 VMVM2HA150GP S828 VMVM2HA175GP S828 VMVM2HA150G245 S828 VMVM2HA175G245 S828 VMVM2HA150R5 S828 VMVM2HA175R5 S828 Ceiling Mount Thru-Feed 3 /4 1 3 /4 1 150 VMVM2C150GP VMVM3C150GP VMVM2C175GP VMVM3C175GP VMVM2C150G245 VMVM3C150G245 VMVM2C175G245 VMVM3C175G245 VMVM2C150R5 VMVM3C150R5 VMVM2C175R5 VMVM3C175R5 3 /4 1 3 /4 1 150 3 175 S828 S828 S828 S828 VMVM2TW150GP VMVM3TW150GP VMVM2TW175GP VMVM3TW175GP 175 S828 S828 S828 S828 S828 S828 S828 S828 VMVM2TW150G245 VMVM3TW150G245 VMVM2TW175G245 VMVM3TW175G245 S828 S828 S828 S828 VMVM2TW150R5 VMVM3TW150R5 VMVM2TW175R5 VMVM3TW175R5 S828 S828 S828 S828 3 /4 /4 150 175 VMVM25Q150GP S828 VMVM25Q175GP S828 VMVM25Q150G245 S828 VMVM25Q175G245 S828 VMVM25Q150R5 S828 VMVM25Q175R5 S828 Stanchion Mount 25° Angle 11/2 11/2 150 175 VMVMJ150GP S828 VMVMJ175GP S828 VMVMJ150G245 S828 VMVMJ175G245 S828 VMVMJ150R5 S828 VMVMJ175R5 S828 Stanchion Mount Straight 11/2 11/2 150 175 VMVMP150GP S828 VMVMP175GP S828 VMVMP150G245 S828 VMVMP175G245 S828 VMVMP150R5 S828 VMVMP175R5 S828 3 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Multi Tap /MT 120V /120 480V /480 CEC/CSA (cUL) Tri Tap /TT 120V /120 Optional Voltage Ballasts - 50 or 60Hz EXPORT 964 S828 S828 S828 S828 Quad-Mount Pendant, Adjustable ThruFeed, 25° Angle, 121/ 2° Angle † For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A150R2-S828. For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A150R3-S828. Voltage Suffix S828 S828 S828 S828 3 * For G241 Type I Compact Refractor, change "245" at end of catalog number to "241". Ex. VMVM2A150G241-S828 For G243 Type III Compact Refractor, change "245" at end of catalog number to "243". Ex. VMVM2A150G243-S828 Voltage Suffix VMVM2A150R5 VMVM3A150R5 VMVM2A175R5 VMVM3A175R5 Flexible Pendant Mount Wall Mount Thru-Feed 3L 175 BASIC CATALOG NUMBER With G245 Type V With R5 Glass Compact Refractor * Refractor † 220V 60Hz /220 www.crouse-hinds.com 220V 50Hz /220 50 US: 1-866-764-5454 230V 50Hz /230 50 CAN: 1-800-265-0502 240V 50Hz /240 50 Copyright© 2013 Eaton’s Crouse-Hinds Business 964-965.qxp 12/16/2013 7:18 PM Page 965 Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) VMV Series 70–175W Metal Halide Champ® H.I.D. Luminaires Marine & Wet Locations 3, 3R, 4, 4X; IP66 3L To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By Components page. Mounting Style Hub Size Pendant Mount 3 /4 1 3 /4 1 3 /4 1 Lamp Watts With G24 Globe and P21 Guard BASIC CATALOG NUMBER With G241 Type I With R5 Glass Compact Refractor * Refractor † 70 VMVM2A070GP VMVM3A070GP VMVM2A100GP VMVM3A100GP VMVM2A175GP VMVM3A175GP VMVM2A070G241 VMVM3A070G241 VMVM2A100G241 VMVM3A100G241 VMVM2A175G241 VMVM3A175G241 VMVM2A070R5 VMVM3A070R5 VMVM2A100R5 VMVM3A100R5 VMVM2A175R5 VMVM3A175R5 100 175 Flexible Pendant Mount 3 /4 /4 3 /4 70 100 175 VMVM2HA070GP VMVM2HA100GP VMVM2HA175GP VMVM2HA070G241 VMVM2HA100G241 VMVM2HA175G241 VMVM2HA070R5 VMVM2HA100R5 VMVM2HA175R5 Ceiling Mount Thru-Feed 3 /4 1 3 /4 1 3 /4 1 70 VMVM2C070GP VMVM3C070GP VMVM2C100GP VMVM3C100GP VMVM2C175GP VMVM3C175GP VMVM2C070G241 VMVM3C070G241 VMVM2C100G241 VMVM3C100G241 VMVM2C175G241 VMVM3C175G241 VMVM2C070R5 VMVM3C070R5 VMVM2C100R5 VMVM3C100R5 VMVM2C175R5 VMVM3C175R5 VMVM2TW070GP VMVM3TW070GP VMVM2TW100GP VMVM3TW100GP VMVM2TW175GP VMVM3TW175GP VMVM2TW070G241 VMVM3TW070G241 VMVM2TW100G241 VMVM3TW100G241 VMVM2TW175G241 VMVM3TW175G241 VMVM2TW070R5 VMVM3TW070R5 VMVM2TW100R5 VMVM3TW100R5 VMVM2TW175R5 VMVM3TW175R5 Wall Mount Thru-Feed Quad-Mount 3 3 /4 1 3 /4 1 3 /4 1 100 175 70 100 175 3 /4 /4 3 /4 70 100 175 VMVM25Q070GP VMVM25Q100GP VMVM25Q175GP VMVM25Q070G241 VMVM25Q100G241 VMVM25Q175G241 VMVM25Q070R5 VMVM25Q100R5 VMVM25Q175R5 Stanchion Mount 25° Angle 11/2 11/2 11/2 70 100 175 VMVMJ070GP VMVMJ100GP VMVMJ175GP VMVMJ070G241 VMVMJ100G241 VMVMJ175G241 VMVMJ070R5 VMVMJ100R5 VMVMJ175R5 Stanchion Mount Straight 11/2 11/2 11/2 70 100 175 VMVMP070GP VMVMP100GP VMVMP175GP VMVMP070G241 VMVMP100G241 VMVMP175G241 VMVMP070R5 VMVMP100R5 VMVMP175R5 3L Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle 3 * For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVM2A070G243 For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVM2A070G245 † For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A070R2. For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A070R3. 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz 2. 70W ballast not available in 480V. NEC/UL Voltage Suffix Multi Tap /MT 120V /120 480V /480 Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 480V CWI /240CWI 3. Options - Add the required option suffixes, see page 962, in alpha-numeric order. CEC/CSA (cUL) 600V CWI /600CWI www.crouse-hinds.com 120V /120 EXPORT 220V 60Hz /220 220V 50Hz /220 50 US: 1-866-764-5454 230V 50Hz /230 50 240V 50Hz /240 50 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 965 966-967.qxp 12/16/2013 7:18 PM Page 966 VMV Series – Ordering by Components 3L VMV luminaires are available in components. A complete luminaire consists of: I. Champ Cover (Mounting Module) II. VMV Ballast Housing – Include voltage and required option(s) III. Optical & Guard components – Globe, Reflector, Refractor, Guard I. Champ Cover (Mounting Module): Type Pendant Conduit Cat. # /4" 1" APM2 APM3 3 Flexible Pendant 3 /4" HPM2 Ceiling 3 /4" 1" CM2 CM3 Wall 3 /4" 1" TWM2 TWM3 Stanchion – 25 Degree Angle 11/2" JM5 Stanchion – Straight 1 /2" PM5 Quad-Mount 3 /4" QM25 1 II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Cat. # For Globe and Compact Refractor Cat. # For Large Refractor Lamp Watts High Pressure Sodium 50 70 100 150 VMVS050/DT VMVS070/MT VMVS100/MT VMVS150/MT LX VMVS050/MT RM VMVS070/MT RM VMVS100/MT RM VMVS150/MT LX RM Metal Halide 70 100 175 VMVM070/MT VMVM100/MT VMVM175/MT VMVM070/TT RM VMVM100/MT RM VMVM175/MT RM 3L Lamp Type III. Globe, Reflectors, Refractors, Guards: Type Cat. # Globe Globe – Teflon Coated Globe Guard Reflector – Dome Reflector – Angle Compact Refractor Type 1 Compact Refractor Type 3 Compact Refractor Type 5 Compact Refractor Guard Large Refractor Type 2 Large Refractor Type 3 Large Refractor Type 5 Large Refractor Guard Large Plastic Refractor Type 2 Large Plastic Refractor Type 3 Large Plastic Refractor Type 5 G24 G24 S808 P21 RD70 RA70 966 www.crouse-hinds.com G241 G243 G245 P241 R2 R3 R5 P23 PR2 PR3 PR5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 966-967.qxp 12/16/2013 7:18 PM Page 967 VMV Series 3L Family Tree Champ® H.I.D. Luminaires 3L *Plastic refractors are for non-hazardous areas only (50–100W Max.) www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 967 968-969.qxp 12/16/2013 7:18 PM Page 968 Temperature Performance Data VMV Series 3L Champ® H.I.D. Luminaires Rated Ambient °C Lamp Cat. # Class II, Division 1 Class I, Division 2 Globe (G24, G241, G245) Class I, Zone 2 Supply Wire Suitable For °C Globe Globe (G24) Restricted (G24) w/ w/ or w/o Simultaneous Breathing Suffix Factory Globe Reflector Refractor Reflector Presence S826 w/ Sealed (G24, Refractor (RA70 or (R2, R3, (RA70 or Class I, Div. 2 Globe (G24, Suffix S865 G241, (R2, R3, RD70) or R5) Group RD70) Class II, Div. 2 G241, G245) AEx nA nR II G245) or R5) Wattage Type VMVM70 VMVM70 VMVM70 VMVM100 VMVM100 S849 VMVM100 VMVM150 VMVM175 70 70 70 100 100 100 150 175 MH MH MH MH MH MH MH MH 40 55 65 40 40 55 40 40 T3A T3 T3 T2D T2 T2D T2A T2A T3A T3 T3 T2D T2 T2D T2A T2A T3A T3 T3 T2D T2 T2D T2B T2B VMVS50 VMVS50 VMVS50 VMVS70 VMVS70 VMVS100 VMVS100 VMVS150 VMVS150 50 50 50 70 70 100 100 150 150 HPS HPS HPS HPS HPS HPS HPS HPS HPS 40 55 65 40 55 40 55 40 55 T3A T3A T3 T3 T3 T2C T2B T2A T2 T3A T3A T3 T3 T3 T2C T2B T2A T2 T3B T3A T3 T3B T3 T2D T2C T2B T2A VMVIG055 VMVIG055 55 55 Induction Induction 40 55 T2C T2C T2C T2C — — EFG EFG EFG EFG EFG EFG EFG T4A T4 T4 T3C T3C T3A T3A T3 T2D T2C T2B T2A T5 T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 90 90 90 90 75 90 90 90 90 90 90 90 75 90 90 90 T5 T5 T5 T4 T4 T4 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 75 75 75 75 90 90 105 90 105 65 75 75 65 90 75 90 85 105 T6 T5 — — 65 65 — — The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL844 specifies how the temperatures are measured. 3L The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1 states that equipment "…for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2 locations…" then these luminaires are suitable for Class I, Division 2 but with cooler temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844. 968 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 968-969.qxp 12/16/2013 7:18 PM Page 969 Dimensions and Weights VMV Series 3L Champ® H.I.D. Luminaires Dimensions Net Luminaire Weights: In Inches: Lamp Watts Luminaire Series 50 70 Luminaire with Globe, Guards (lbs.): VMVS 131/2 141/2 VMVM 13 Luminaire with Glass Refractor (lbs.): VMVS 213/4 223/4 VMVM 21 Pendant Mount Ceiling Mount Top View Type Lbs. Add for mounting modules: Pendant 11/4 Flexible Pendant 11/2 Ceiling 23/4 Wall 41/2 Add for reflectors: Dome 11/2 100 150 141/2 131/4 141/2 223/4 211/2 223/4 175 151/2 233/4 Type Lbs. Quad-Mount Angle Stanchion Straight Stanchion 31/ 2 31/ 2 41/ 2 30° Angle 11/ 2 Deduct: /2" lb. for fixture without P21 Guard 1 Quad-Mount Ceiling Mount 25° Angle Stanchion Mount Straight Stanchion Mount Luminaire With: Refractors, Guard 3L Wall Mount Compact Refractor Globe, Guard, Reflectors www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 969 970-971.qxp 12/16/2013 7:18 PM Page 970 VMV Series 3L Photometric Data Champ® H.I.D. Luminaires Lamp: 100W/E – 231/2 high pressure sodium (HPS) Total bare lamp lumens: 9500 NOTE: All data provided is for high pressure sodium luminaires with 100W/E–23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Eaton's Crouse-Hinds for additional photometric data on any Champ Series luminaire. Luminaire with Globe and Dome Reflector Multipliers (for use with candela curve only). ConLuminaire Lamp version Series Watts Factor VMVS 50 70 150 Isofootcandle Chart: Luminaire with Globe and Dome Reflector 0.42 0.67 1.68 Luminaire spacing ratio: 1.85 Coefficient of Utilization Effective Floor Cavity Reflectance 20% 3L % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .823 .784 .749 .707 .646 .594 .610 .538 .482 .529 .451 .391 .464 .384 .324 70 50 30 10 .804 .767 .734 .690 .633 .587 .597 .530 .477 .517 .445 .388 .452 .377 .321 50 50 30 10 .765 .735 .709 .658 .611 .569 .571 .513 .466 .494 .431 .381 .434 .368 .318 30 50 30 10 .731 .708 .685 .629 .591 .555 .546 .497 .456 .473 .419 .375 .416 .357 .312 10 50 30 10 .701 .681 .662 .603 .569 .541 .524 .482 .446 .454 .406 .367 .399 .348 .307 0 0 .644 .521 .427 .348 .288 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .412 .334 .278 .366 .290 .239 .326 .253 .201 .296 .224 .175 .258 .187 .142 70 50 30 10 .403 .329 .274 .359 .285 .235 .320 .250 .200 .291 .221 .174 .252 .187 .142 50 50 30 10 .386 .320 .271 .344 .277 .231 .307 .244 .197 .279 .216 .172 .244 .182 .140 30 50 30 10 .371 .312 .267 .329 .272 .227 .296 .237 .195 .269 .210 .170 .235 .178 .137 Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. 50 30 10 .357 .304 .263 .319 .266 .224 .285 .232 .192 .260 .206 .167 .227 .173 .135 Height (Ft.) Factor Height (Ft.) Factor 10 0.51 0.39 0 .245 .207 .176 .152 .120 2.78 1.56 0.70 14 16 0 6 8 12 % Reflectance Eff. Ceil. Wall 970 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Copyright© 2013 Eaton’s Crouse-Hinds Business 970-971.qxp 12/16/2013 7:18 PM Page 971 VMV Series Photometric Data 3L Champ® H.I.D. Luminaires Lamp: 100W/E0 – 231/2 high pressure sodium (HPS) Coefficient of Utilization Effective Floor Cavity Reflectance 20% Luminaire with I.E.S. Type V Glass Refractor Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .848 .796 .750 .709 .631 .566 .597 .509 .439 .508 .414 .341 .437 .343 .271 70 Conversion Factor 50 30 10 .818 .770 .726 .682 .611 .552 .576 .493 .428 .489 .402 .334 .419 .331 .264 50 0.42 0.67 1.68 50 30 10 .759 .720 .685 .632 .574 .521 .533 .464 .407 .451 .377 .318 .389 .312 .253 30 50 30 10 .706 .675 .645 .586 .538 .495 .493 .435 .386 .417 .354 .302 .359 .291 .240 10 50 30 10 .658 .632 .608 .544 .504 .469 .457 .408 .366 .385 .331 .286 .331 .274 .227 0 0 .581 .441 .340 .260 .203 NOTE: Photometric data was developed using a 100 watt clear high pressure sodium lamp (9500 lumens). For other clear lamps, use the following conversion factors (multipliers): Luminaire Lamp Series Watts VMVS 50 70 150 % Reflectance Eff. Ceil. Wall Luminaire spacing ratio: 2.0 % Reflectance Eff. Ceil. Wall US: 1-866-764-5454 9 10 80 50 30 10 .384 .292 .226 .337 .249 .189 .299 .214 .154 .272 .189 .132 .238 .159 .103 70 50 30 10 .369 .283 .218 .325 .240 .182 .288 .203 .150 .262 .183 .130 .229 .156 .105 50 50 30 10 .341 .266 .209 .301 .225 .173 .266 .195 .143 .243 .173 .124 .214 .146 .099 30 50 30 10 .316 .249 .199 .277 .213 .163 .248 .182 .136 .225 .161 .117 .198 .136 .093 10 50 30 10 .292 .233 .188 .258 .200 .154 .223 .171 .128 .209 .151 .110 .134 .127 .087 0 0 .165 .133 .108 .091 .070 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 3L www.crouse-hinds.com Room Cavity Ratio 6 7 8 971 972-973.qxp 12/16/2013 7:19 PM Page 972 LMV Series 50-150W Low Profile Medium Base 3L Champ® H.I.D. Luminaires Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (HPS 35W, 50W) Marine & Wet Locations 3, 3R, 4, 4X; IP66 Applications: Options: LMV series Champ® luminaires are used: • In applications involving low luminaire mounting heights or restricted mounting space or where luminaire weight is a factor • In areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions • Where combustible dusts are present • Where combustible dusts and flammable vapors are present simultaneously • In elevated ambient temperatures often found in industrial applications • In marine applications where water spray and corrosive atmospheres are considerations • Wherever the damaging effects of wind, snow, sleet, or hot sun are found • In manufacturing plants, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore or dockside installations, cold storage facilities, parking garages or wherever dust, dirt, water, vibration and rough usage are a problem The following special options are available from the factory by adding suffix to luminaire Cat. No.: Description Suffix • Restricted Breathing Construction ............................. S826 Class I, Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) • Certified for IEC Zone 2............. S826TB Furnished with terminal block, crimp terminals and dedicated voltage ballasts (no MT, DT, or TT) • Fused – to protect ballast and capacitors against abnormal line conditions .......................... S658* (Not for use in Canada) (Not suitable for marine applications) • Quick-Clip - Holds weight of housing when closed. No need to support luminaire while screwing the housing to the cover ........................................ S890 • Ballast-Gard™ starter cut-out switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50–100W HPS only ............ BG • Factory assembled with H.I.D. lamps installed for additional labor savings ............................. FA • Stainless steel insert – top hat with stainless steel threaded insert to attach ballast housing .......................... S806 Features: 3L Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) • Compact, lightweight design is ideal for low mounting heights. • Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion. • Seven mounting arrangements to suit any lighting layout – pendant, flexible pendant, ceiling, wall, straight stanchion, angle stanchion, and quad-mount. • Wide range of lamp wattages to meet specifiers' needs: 50, 70, 100 and 150 watt (HPS); 70 and 100 watt (MH) medium base lamps. • Hinged ballast housing for ease of installation and maintenance. • All luminaires designed to perform in a 40°C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. • Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. • Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation. • Low ambient capability to –40°C. • Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode. • Grounding wire for safety. • Medium base lamp sockets. 972 www.crouse-hinds.com US: 1-866-764-5454 Certifications and Compliances: • NEC/CEC: Class I, Division 2, Groups A, B, C, D HPS 35W, 50W – Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 • IEC: Zone 2 Ex nR IIC • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 Standard Materials: • Ballast housings and mountings – copper-free aluminum (less than 0.4 of 1%) • Exterior hardware – stainless steel • Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material • Globes – heat and impact resistant, internally fluted glass • Guards – copper-free aluminum Accessories: • See pages 1022–1023 for complete listing Standard Finishes: • Copper-free aluminum – epoxy powder coat • Krydon material – high reflectance white • Stainless steel – natural Electrical Ratings: • 120 volts, dual-tap (120/277), multi-tap* • 50, 70, 100, 150 watts HPS** • 70 and 100 watts MH * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. ** 150W HPS is not avalable with multi tap ballast. 120V only. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 972-973.qxp 12/16/2013 7:19 PM Page 973 Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) LMV Series 50–150W High Pressure Sodium Low Profile - Medium Base Champ® H.I.D. Luminaires Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (35W, 50W) Marine & Wet Locations 3, 3R, 4, 4X; IP66 3L To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Style Hub Size Lamp Watts With G54 Globe and P50 Guard Pendant Mount 3 /4 1 3 /4 1 3 /4 1 3 /4 1 50 LMVS2A050GP LMVS3A050GP LMVS2A070GP LMVS3A070GP LMVS2A100GP LMVS3A100GP LMVS2A150GP LMVS3A150GP /4 /4 3 /4 3 /4 50 70 100 150 LMVS2HA050GP LMVS2HA070GP LMVS2HA100GP LMVS2HA150GP 3 /4 1 /4 1 3 /4 1 3 /4 1 50 3 70 LMVS2C050GP LMVS3C050GP LMVS2C070GP LMVS3C070GP LMVS2C100GP LMVS3C100GP LMVS2C150GP LMVS3C150GP /4 1 3 /4 1 3 /4 1 3 /4 1 50 Flexible Pendant Mount 3 3 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 3 70 100 150 100 150 70 100 150 LMVS2TW050GP LMVS3TW050GP LMVS2TW070GP LMVS3TW070GP LMVS2TW100GP LMVS3TW100GP LMVS2TW150GP LMVS3TW150GP 3 /4 /4 3 /4 3 /4 50 70 100 150 LMVS25Q050GP LMVS25Q070GP LMVS25Q100GP LMVS25Q150GP Stanchion Mount 25° Angle 11/2 11/2 11/2 11/2 50 70 100 150 LMVSJ050GP LMVSJ070GP LMVSJ100GP LMVSJ150GP Stanchion Mount Straight 11/2 11/2 11/2 11/2 50 70 100 150 LMVSP050GP LMVSP070GP LMVSP100GP LMVSP150GP 3 3L Quad Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT Dual Tap /DT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT Dual Tap /DT 120V /120 2. 150W HPS Luminaires: For 55V lamps - add suffix LX. 50W HPS luminaire is dual tap only. 150W HPS is not avalable with multi tap ballast. 120V only. 3. Options - Add the required option suffixes, see page 972, in alpha-numeric order. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 973 974-975.qxp 12/16/2013 3L 7:19 PM Page 974 LMV Series 70-100W Metal Halide Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Low Profile - Medium Base Champ® H.I.D. Luminaires Marine & Wet Locations 3, 3R, 4, 4X; IP66 To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Style Pendant Mount Hub Size Lamp Watts With G54 Globe and P50 Guard 3 /4 1 3 /4 1 70 LMVM2A070GP LMVM3A070GP LMVM2A100GP LMVM3A100GP 100 /4 /4 70 100 LMVM2HA070GP LMVM2HA100GP 3 /4 1 3 /4 1 70 LMVM2C070GP LMVM3C070GP LMVM2C100GP LMVM3C100GP 3 /4 1 3 /4 1 70 Stanchion Mount 25° Angle 11/2 11/2 70 100 LMVMJ070GP LMVMJ100GP Stanchion Mount Straight 11/2 11/2 70 100 LMVMP070GP LMVMP100GP 3 Flexible Pendant Mount 3 Ceiling Mount Thru-Feed LMVM2TW070GP LMVM3TW070GP LMVM2TW100GP LMVM3TW100GP 100 3L Wall Mount Thru-Feed 100 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT 120V /120 2. 70W ballast not available in 480V. 3. Options - Add the required option suffixes, see page 972, in alpha-numeric order. 974 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 974-975.qxp 12/16/2013 7:19 PM Page 975 LMV Series – Ordering by Components 3L LMV luminaires are available in components. A complete luminaire consists of: I. II. III. Champ Cover (Mounting Module) LMV Ballast Housing – Include voltage and required option(s) Globe, Guard, Reflector I. Champ Cover (Mounting Module): Type Pendant Conduit Cat. # /4" 1" APM2 APM3 3 Flexible Pendant 3 /4" HPM2 Ceiling 3 /4" 1" CM2 CM3 Wall 3 /4" 1" TWM2 TWM3 Stanchion – 25 Degree Angle 11/2" JM5 Stanchion – Straight 1 /2" PM5 Quad-Mount 3 /4" QM25 1 II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type Lamp Watts Cat. # High Pressure Sodium 50 70 100 150 LMVS050/120 LMVS070/MT LMVS100/MT LMVS150/120 LX Metal Halide 70 100 LMVM070/MT LMVM100/MT Type Cat. # Globe Globe Guard Reflector – Dome Reflector – Angle G54 P50 RD636 RA636 www.crouse-hinds.com US: 1-866-764-5454 3L III. Globe, Guards and Reflectors: CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 975 976-977.qxp 3L 12/16/2013 7:19 PM Page 976 LMV Series Family Tree 3L Champ® H.I.D. Luminaires 976 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 976-977.qxp 12/16/2013 7:19 PM Page 977 LMV Series Temperature Performance Data 3L Champ® H.I.D. Luminaires Rated Ambient °C Lamp Cat. # Wattage Type LMVS50 LMVS50 LMVS50 LMVS70 LMVS70 LMVS100 LMVS100 50 50 50 70 70 100 100 HPS HPS HPS HPS HPS HPS HPS LMVM70 LMVM70 LMVM100 70 70 100 LMVM150 150 40 55 65 40 55 40 Class I, Division 2 Globe (G54) w/ or w/o Reflector (RA636 or RD636) Class II, Division 1 Globe (G54) w/ or w/o Reflector (RA636 or Group RD636) Simultaneous Presence Class I, Div. 2 Class II, Div. 1 Class I, Zone 2 Restricted Factory Breathing Sealed Suffix Suffix S826 w/ S865 Globe (G24) AEx nA nR II Supply Wire Suitable for °C 50 T2D T2C T2C T2B T2B T2 — EFG — — — — — — T3C — — — — — — T2B — — — — — — T5 T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 T3 T3 T3 N/A 75 85 75 85 85 90 MH MH MH 40 55 40 T2B T2B — — — — — — — — — — T4 T4 T3 T3 T3 T3 75 85 85 HPS 40 T1 350°C — — — — — 85 The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL 844 specifies how the temperatures are measured. The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2 locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844. 3L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 977 978-979.qxp 12/16/2013 7:19 PM Page 978 LMV Series 3L Dimensions and Weights Champ® H.I.D. Luminaires Dimensions Luminaire Net Weights: In Inches: Luminaire Series LMVS LMVM Pendant Mount Luminaire with Globe, Guard (lbs.) 50 70 100 150 73/4 81/4 83/4 91/4 70 100 9 9 Type Add for mounting modules: Pendant Flexible Pendant Ceiling Quad-Mount Wall Angle Stanchion Straight Stanchion Top View Wall Mount Lamp Watts Ceiling Mount Type Add for reflectors: Dome 30° Angle Deduct for luminaire without guard: P50 Guard Luminaire with Globe, Guard, Reflectors Straight Stanchion Mount 25° Angle Stanchion Mount 3L Quad-Mount 978 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Lbs. 11/4 11/2 23/4 31/2 41/2 31/2 41/2 lbs. 1.0 1.0 /2 1 978-979.qxp 12/16/2013 7:19 PM Page 979 Photometric Data LMV Series 3L Champ® H.I.D. Luminaires Lamp: 100W/E-17 high pressure sodium (HPS) Total bare lamp lumens: 9500 All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use conversion factors (multipliers) shown below for other lamp types and wattages. Consult Eaton's Crouse-Hinds for additional photometric data on any Champ Series. Luminaire with Globe and Dome Reflector Multipliers (for use with candela curve only). ConLuminaire Lamp version Series Watts Factor 35 50 70 150 LMVS Isofootcandle Chart: Luminaire with Globe and Dome Reflector 0.24 0.42 0.67 1.68 Luminaire spacing ratio: 2.0 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .722 .691 .663 .628 .579 .537 .545 .487 .441 .473 .408 .358 .413 .346 .296 70 50 30 10 .705 .676 .650 .613 .568 .531 .534 .479 .436 .463 .403 .355 .403 .340 .293 50 50 30 10 .671 .647 .627 .585 .548 .514 .511 .464 .426 .442 .390 .349 .387 .332 .289 30 50 30 10 .641 .623 .605 .560 .529 .501 .489 .450 .416 .424 .379 .342 .371 .322 .284 10 50 30 10 .614 .598 .584 .537 .510 .488 .470 .436 .407 .407 .367 .335 .356 .341 .279 0 0 .568 .471 .391 .319 .263 Wall 6 7 8 9 10 80 50 30 10 .366 .300 .253 .324 .259 .215 .288 .225 .180 .261 .199 .156 .226 .165 .127 70 50 30 10 .358 .295 .249 .318 .255 .212 .282 .223 .179 .256 .196 .156 .221 .165 .126 50 50 30 10 .343 .288 .246 .305 .248 .209 .271 .217 .177 .246 .192 .154 .214 .161 .124 30 50 30 10 .330 .280 .242 .292 .243 .205 .261 .210 .175 .237 .186 .152 .206 .157 .122 10 50 30 10 .317 .272 .238 .282 .237 .202 .251 .206 .172 .228 .182 .149 .199 .152 .120 0 0 .223 .187 .158 .136 .107 % Reflectance Eff. Ceil Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector 3L Wall Room Cavity Ratio www.crouse-hinds.com US: 1-866-764-5454 Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 6 8 12 2.78 1.56 0.70 14 16 0.51 0.39 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 979 980-981.qxp 12/16/2013 7:20 PM Page 980 DMV Series 50-250W For Combustible Dusts 3L Champ® H.I.D. Luminaires Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (175W max) Marine & Wet Locations 3, 3R, 4, 4X; IP66 Applications: Options: DMV series Champ luminaires are used: The following special options are available from the factory by adding suffix to luminaire Cat. No.: • In applications made hazardous by the presence of combustible dusts • In areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions • In marine applications where water spray and corrosive atmospheres are considerations • In areas where combustible dusts and flammable vapors are present simultaneously • In elevated ambient temperatures often found in industrial applications • In installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems • Wherever the damaging effects of wind, snow, sleet, or hot sun are found • In grain handling, storage and processing plants, coal preparation plants, coal conveying areas, food processing plants, manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore, dockside, and harbor installations, and other heavy industrial applications Features: 3L Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) • Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion. • Seven mounting arrangements to suit any lighting layout – pendant, flexible pendant, ceiling, wall bracket, angle stanchion, straight stanchion, and quad-mount. • Wide range of light sources and wattages to meet specifiers' needs: 50, 70, 100, 150 watt high pressure sodium (HPS); 70, 100, 175, 250 watt metal halide. • Hinged ballast housing for ease of installation and maintenance. • All luminaires designed to perform in a 40°C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. • Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. • Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation. • Low ambient capability to (–40°C.) • Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode. • Mogul base porcelain lamp socket. • Stainless steel open bottom guard permits direct access to the globe for easy relamping. 980 www.crouse-hinds.com US: 1-866-764-5454 Description • Grounding wire for safety. • Ballasts available in voltages of 120, 208, 240, 277, 347, 480, 600 and multi-tap.* Certifications and Compliances: • NEC/CEC: Class I, Division 2, Groups A, B, C, D 175W max – Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 • IEC: Zone 2 Ex nR IIC • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 Standard Materials: • Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1% copper) • Guard and exterior hardware – stainless steel • Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material • Globes – heat and impact resistant, internally fluted glass Standard Finishes: • Copper-free aluminum – epoxy powder coat • Krydon material – high reflectance white • Stainless steel – natural Electrical Ratings: • 120, multi-tap* (120, 208, 240 and 277), tri-tap (120, 277, 347) 480, 600 volts • 50–250W HPS; 70–250W MH CAN: 1-800-265-0502 Suffix • Restricted Breathing Construction . . . S826 Class I, Division 2 & Zone 2 Suitabilty Cooler Operating Temperatures (T-Numbers) • Restricted Breathing/Non-Sparking . . S865 Class I, Division 2 & Zone 2 Provides T3 code without conduit or cable seals • Certified for IEC Zone 2 . . . . . . . . . . S826TB Furnished with terminal block, crimp terminals and dedicated voltage ballasts (no MT, DT or TT) • Fused – to protect ballast and capacitors against abnormal line conditions . . . . . . . . . . . . . . . . . . . . S658* (Not available with /MT Ballast) (Not for use in Canada) (Not suitable for marine applications) • Quick-Clip - Holds weight of housing when closed. No need to support luminaire while screwing the housing to the cover . . . . . . . . . S890 • Ballast-Gard™ starter cut-out switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50–150W LX HPS only . . . . . . . . . . . . . . . . . . . . . BG • Instant restrike – enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. 50–150W LX HPS only . . . . . . . . . IR 50–100W LX HPS only . . . . . . . . . TIR • Quartz auxiliary lighting – comes to full brightness immediately and remains lit until the HID lamp attains 60–70% of full illumination. For non-hazardous locations only. (Note: QTZ lamp not included; use 100W single ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC) Consult factory for top-hat limitations . . . . . . . . . . . . . . . . . . . . . QTZ • Factory assembled with H.I.D. lamps installed for additional labor savings . . . . . . . . . . . . . . . . . . . . . . . FA • TEFLON® coated globe for additional protection against breakage. For use with 50–150W HPS and 70–175W MH (G303 only) . . . . . . . . . . . . . . . . . S808 Note: Some T-numbers (operating temperatures) change. See "Temperature Performance Data" section. • Stainless steel insert – top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . S806 Note: BG and IR options cannot be used together. IR and QTZ options cannot be used together. Accessories: • See pages 1022–1023 for complete listing. TEFLON is a registered trademark of E.I. duPont Co. *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Copyright© 2013 Eaton’s Crouse-Hinds Business 980-981.qxp 12/16/2013 7:20 PM Page 981 DMV Series 50-150W High Pressure Sodium For Combustible Dust Applications Champ® H.I.D. Luminaires Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 3L To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Hub Lamp With G303 Globe With GR305 Glass Style Size Watts and P33 Guard Refractor * Pendant Mount 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 50 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 50 Stanchion Mount 25° Angle Stanchion Mount Straight Flexible Pendant Mount Ceiling Mount Thru-Feed Wall Mount Thru-Feed Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle DMVS2A050GP DMVS3A050GP DMVS2A070GP DMVS3A070GP DMVS2A100GP DMVS3A100GP DMVS2A150GP DMVS3A150GP DMVS2HA050GP DMVS2HA070GP DMVS2HA100GP DMVS2HA150GP DMVS2A050GR305 DMVS3A050GR305 DMVS2A070GR305 DMVS3A070GR305 DMVS2A100GR305 DMVS3A100GR305 DMVS2A150GR305 DMVS3A150GR305 DMVS2HA050GR305 DMVS2HA070GR305 DMVS2HA100GR305 DMVS2HA150GR305 50 70 100 150 DMVS2C050GP DMVS3C050GP DMVS2C070GP DMVS3C070GP DMVS2C100GP DMVS3C100GP DMVS2C150GP DMVS3C150GP DMVS2TW050GP DMVS3TW050GP DMVS2TW070GP DMVS3TW070GP DMVS2TW100GP DMVS3TW100GP DMVS2TW150GP DMVS3TW150GP DMVS25Q050GP DMVS25Q070GP DMVS25Q100GP DMVS25Q150GP DMVS2C050GR305 DMVS3C050GR305 DMVS2C070GR305 DMVS3C070GR305 DMVS2C100GR305 DMVS3C100GR305 DMVS2C150GR305 DMVS3C150GR305 DMVS2TW050GR305 DMVS3TW050GR305 DMVS2TW070GR305 DMVS3TW070GR305 DMVS2TW100GR305 DMVS3TW100GR305 DMVS2TW150GR305 DMVS3TW150GR305 DMVS25Q050GR305 DMVS25Q070GR305 DMVS25Q100GR305 DMVS25Q150GR305 11/2 11/2 11/2 11/2 50 70 100 150 DMVSJ050GP DMVSJ070GP DMVSJ100GP DMVSJ150GP DMVSJ050GR305 DMVSJ070GR305 DMVSJ100GR305 DMVSJ150GR305 11/2 11/2 11/2 11/2 50 70 100 150 DMVSP050GP DMVSP070GP DMVSP100GP DMVSP150GP DMVSP050GR305 DMVSP070GR305 DMVSP100GR305 DMVSP150GR305 70 100 150 50 70 100 150 70 100 150 50 70 100 150 3L * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVS2A050GR302 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVS2A050GR303 2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps - add suffix CE. 50W HPS luminaire is dual tap only. 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT Dual Tap /DT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT Dual Tap /DT 600V CWI /600CWI 220V 60Hz /220 220V 50Hz /220 50 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI www.crouse-hinds.com 120V /120 3. Options - Add the required option suffixes, see page 980, in alpha-numeric order. EXPORT US: 1-866-764-5454 230V 50Hz /230 50 240V 50Hz /240 50 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 981 982-983.qxp 12/16/2013 7:20 PM Page 982 3L DMV Series - 150-250W Pulse Start Metal Halide Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) For Combustible Dust Applications Champ® H.I.D. Luminaires Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (175W max) Marine & Wet Locations 3, 3R, 4, 4X; IP66 To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see DMV Series - Ordering By Components page. Mounting Style Lamp Watts With G303 Globe and P33 Guard 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 150 DMVM2A150GP S828 DMVM3A150GP S828 DMVM2A175GP S828 DMVM3A175GP S828 DMVM2A200GP S828 DMVM3A200GP S828 DMVM2A250GP S828 DMVM3A250GP S828 DMVM2HA150GP S828 DMVM2HA175GP S828 DMVM2HA200GP S828 DMVM2HA250GP S828 DMVM2A150GR305 S828 DMVM3A150GR305 S828 DMVM2A175GR305 S828 DMVM3A175GR305 S828 DMVM2A200GR305 S828 DMVM3A200GR305 S828 DMVM2A250GR305 S828 DMVM3A250GR305 S828 DMVM2HA150GR305 S828 DMVM2HA175GR305 S828 DMVM2HA200GR305 S828 DMVM2HA250GR305 S828 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 150 150 175 200 250 DMVM2C150GP S828 DMVM3C150GP S828 DMVM2C175GP S828 DMVM3C175GP S828 DMVM2C200GP S828 DMVM3C200GP S828 DMVM2C250GP S828 DMVM3C250GP S828 DMVM2TW150GP S828 DMVM3TW150GP S828 DMVM2TW175GP S828 DMVM3TW175GP S828 DMVM2TW200GP S828 DMVM3TW200GP S828 DMVM2TW250GP S828 DMVM3TW250GP S828 DMVM25Q150GP S828 DMVM25Q175GP S828 DMVM25Q200GP S828 DMVM25Q250GP S828 DMVM2C150GR305 S828 DMVM3C150GR305 S828 DMVM2C175GR305 S828 DMVM3C175GR305 S828 DMVM2C200GR305 S828 DMVM3C200GR305 S828 DMVM2C250GR305 S828 DMVM3C250GR305 S828 DMVM2TW150GR305 S828 DMVM3TW150GR305 S828 DMVM2TW175GR305 S828 DMVM3TW175GR305 S828 DMVM2TW200GR305 S828 DMVM3TW200GR305 S828 DMVM2TW250GR305 S828 DMVM3TW250GR305 S828 DMVM25Q150GR305 S828 DMVM25Q175GR305 S828 DMVM25Q200GR305 S828 DMVM25Q250GR305 S828 Stanchion Mount 25° Angle 11/2 11/2 11/2 11/2 150 175 200 250 DMVMJ150GP DMVMJ175GP DMVMJ200GP DMVMJ250GP S828 S828 S828 S828 DMVMJ150GR305 DMVMJ175GR305 DMVMJ200GR305 DMVMJ250GR305 S828 S828 S828 S828 Stanchion Mount Straight 11/2 11/2 11/2 11/2 150 175 200 250 DMVMP150GP DMVMP175GP DMVMP200GP DMVMP250GP S828 S828 S828 S828 DMVMP150GR305 DMVMP175GR305 DMVMP200GR305 DMVMP250GR305 S828 S828 S828 S828 Pendant Mount Flexible Pendant Mount Ceiling Mount Thru-Feed Wall Mount Thru-Feed Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle 3L BASIC CATALOG NUMBER With GR305 Glass Refractor * Hub Size 175 200 250 150 175 200 250 175 200 250 150 175 200 250 * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A150GR302-S828 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A150GR303-S828 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT 230V 50Hz /230 50 240V 50Hz /240 50 120V /120 Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage Suffix 220V 60Hz /220 220V 50Hz /220 50 2. Options - Add the required option suffixes, see page 980, in alpha-numeric order. 982 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 982-983.qxp 12/16/2013 7:20 PM Page 983 DMV Series 70–250W Metal Halide Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) For Combustible Dust Applications Champ® H.I.D. Luminaires Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (175W max) Marine & Wet Locations 3, 3R, 4, 4X; IP66 3L To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page. BASIC CATALOG NUMBER With GR305 Glass Refractor * Mounting Style Hub Size Lamp Watts With G303 Globe and P33 Guard Pendant Mount 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 70 DMVM2A070GP DMVM3A070GP DMVM2A100GP DMVM3A100GP DMVM2A175GP DMVM3A175GP DMVM2A250GP DMVM3A250GP DMVM2HA070GP DMVM2HA100GP DMVM2HA175GP DMVM2HA250GP DMVM2A070GR305 DMVM3A070GR305 DMVM2A100GR305 DMVM3A100GR305 DMVM2A175GR305 DMVM3A175GR305 DMVM2A250GR305 DMVM3A250GR305 DMVM2HA070GR305 DMVM2HA100GR305 DMVM2HA175GR305 DMVM2HA250GR305 3 /4 1 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 3 /4 3 /4 3 /4 70 3 100 70 100 175 250 DMVM2C070GP DMVM3C070GP DMVM2C100GP DMVM3C100GP DMVM2C175GP DMVM3C175GP DMVM2C250GP DMVM3C250GP DMVM2TW070GP DMVM3TW070GP DMVM2TW100GP DMVM3TW100GP DMVM2TW175GP DMVM3TW175GP DMVM2TW250GP DMVM3TW250GP DMVM25Q070GP DMVM25Q100GP DMVM25Q175GP DMVM25Q250GP DMVM2C070GR305 DMVM3C070GR305 DMVM2C100GR305 DMVM3C100GR305 DMVM2C175GR305 DMVM3C175GR305 DMVM2C250GR305 DMVM3C250GR305 DMVM2TW070GR305 DMVM3TW070GR305 DMVM2TW100GR305 DMVM3TW100GR305 DMVM2TW175GR305 DMVM3TW175GR305 DMVM2TW250GR305 DMVM3TW250GR305 DMVM25Q070GR305 DMVM25Q100GR305 DMVM25Q175GR305 DMVM25Q250GR305 Stanchion Mount 25° Angle 11/2 11/2 11/2 11/2 70 100 175 250 DMVMJ070GP DMVMJ100GP DMVMJ175GP DMVMJ250GP DMVMJ070GR305 DMVMJ100GR305 DMVMJ175GR305 DMVMJ250GR305 Stanchion Mount Straight 11/2 11/2 11/2 11/2 70 100 175 250 DMVMP070GP DMVMP100GP DMVMP175GP DMVMP250GP DMVMP070GR305 DMVMP100GR305 DMVMP175GR305 DMVMP250GR305 Flexible Pendant Mount Ceiling Mount Thru-Feed Wall Mount Thru-Feed Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/2° Angle 100 175 250 70 100 175 250 175 250 70 100 175 250 3L * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A070GR302 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A070GR303 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT 120V /120 CEC/CSA (cUL) 480V /480 Tri Tap /TT 120V /120 220V 60Hz /220 220V 50Hz /220 50 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts - 175W and 250W MH only Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 600V CWI /600CWI EXPORT 230V 50Hz /230 50 240V 50Hz /240 50 2. 70W ballast not available in 480V. 3. Options - Add the required option suffixes, see page 980, in alpha-numeric order. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 983 984-985.qxp 12/16/2013 7:20 PM Page 984 DMV Series – Ordering by Components 3L DMV luminaires are available in components. A complete luminaire consists of: I. Champ Cover (Mounting Module) II. DMV Ballast Housing – Include voltage and required option(s) III. Globe, Refractor, Guard, Reflector I. Champ Cover (Mounting Module): Type Pendant Conduit Cat. # /4" 1" APM2 APM3 3 Flexible Pendant 3 /4" HPM2 Ceiling 3 /4" 1" CM2 CM3 Wall 3 /4" 1" TWM2 TWM3 Stanchion – 25 Degree Angle 11/2" JM5 Stanchion – Straight 11/2" PM5 Quad-Mount 3 /4" QM25 II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Cat. # DMVS050/MT DMVS070/MT DMVS100/MT DMVS150/MT LX 70 100 175 250 DMVM070/MT DMVM100/MT DMVM175/MT DMVM250/MT 3L Metal Halide Lamp Watts 50 70 100 150 III. Globe, Reflectors, Refractors, Guards: Type Cat. # Globe G303 Globe – Teflon Coated G303S808 Globe Guard P33 Reflector – Dome RD739 Reflector – Angle RA739 Refractor – Type 2 GR302 Refractor – Type 3 Refractor – Type 5 GR303 Large Plastic Refractor Type 2 PGR302 Large Plastic Refractor Type 3 PGR303 Large Plastic Refractor Type 5 PGR305 Refractor Guard P23 High Bay Reflector/Lens GRD4 984 www.crouse-hinds.com GR305 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 984-985.qxp 12/16/2013 7:20 PM Page 985 DMV Series 3L Family Tree Champ® H.I.D. Luminaires 3L *Plastic refractors are non-hazardous areas only (50-100W Max.) www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 985 986-987.qxp 12/16/2013 3L 7:21 PM Page 986 DMV Series Temperature Performance Data Champ® H.I.D. Luminaires Rated Ambient °C Lamp Class II, Division 1 Class I, Zone 2 Cat. # DMVS50 DMVS50 DMVS50 DMVS70 DMVS70 DMVS70 DMVS100 DMVS100 DMVS100 DMVS150 DMVS150 DMVS150 Wattage 50 50 50 70 70 70 100 100 100 150 150 150 Type HPS HPS HPS HPS HPS HPS HPS HPS HPS HPS HPS HPS 40 55 65 40 55 65 40 55 65 40 55 65 DMVM70 DMVM70 DMVM70 DMVM100 DMVM100 DMVM100 DMVM150 DMVM150 DMVM150 DMVM175 DMVM175 DMVM175 DMVM175 DMVM175 DMVM175 DMVM200 DMVM200 DMVM250 DMVM250 70 70 70 100 100 100 150 150 150 175 175 175 175 175 175 200 200 250 250 MH MH MH MH MH MH MH PS MH PS MH PS MH MH MH MH PS MH PS MH PS MH MH MH MH 40 55 65 40 55 65 40 55 65 40 55 65 40 55 65 40 55 40 55 T3C* T3B* T3A* T3* T3* T2D* T2B T2A T2A T2B* T2A* T2A* T2B* T2A* T2A* T2 T1 (325) T2 T1 (325) T3C T3C T3A T3A T3A T2D — — — T2 T2 T2 — — — — — — — T3C — — T3C — — T4A T4 T4 T3C — — T4A T4 T4 — — — — — — — — — — T4A T4 T4 T3C — — T4A T4 T4 — — — — — — — — — — — — — T2A — — — — — — — — — T6 T5 T5 T5 T5 T4 T4 T4 T4 T4 T4 T3 T4 T4 T4 T4 T3 T4 T3 T6 T5 T5 T5 T5 T4 T4 T4 T4 T4 T4 T3 T4 T4 T4 T4 T3 T4 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 90 90 90 90 90 90 105 105 105 90 90 90 105 105 105 90 90 90 90 2 / 26 (52) 2 / 32 (64) 2 / 42 (84) CF CF CF 40 40 40 T3 T3 T3A — — — T6 T6 T4A — T6 T4A — — — T6 T6 T4 T6 T6 T4 T3 T3 — 90 90 90 85 85 165 Induction Induction Induction 40 55 40 T3 T2D T3 T3 T2D — T5 T4A T2D T5 T4A — — — T2D T6 T5 T5 T6 T5 — T5 T4 — 90 90 90 DMVF52 DMVF64 DMVF84 3L Class I, Division 2 Globe (G303) w/ or w/o Reflector (RA739 or RD739)* T3A T3 T3 T3A T3 T3 T2D T2C T2C T2B T2B T2A DMVIG85 DMVIG85 DMVIG165 Refractor (GR302 or GR303 or GR305) T3A T3 T3 T3A T3 T3 T2D T2C T2C T2B T2B T2B Refractor (G302 or G303 or G305) or Globe (G303)† T6 T5 T4A T6 T5 T4A T5 T4A — T3C — — Globe (G303) with Reflector (RA739 or RD739) T6 T5 T4A T6 T5 T4A T5 T4A — T3C — — Simultaneous Presence Class I, Div. 2 Class II, Div. 1 (with G303 Globe only) T3A T3 T3 T3A T3 T3 T3D T2C — T2A — — Restricted Breathing Suffix S826 w/ Globe (G303) T6 T5 T5 T6 T5 T5 T6 T5 T4 T5 T4 — Globe (G303) Factory with Sealed Supply Reflector Suffix Wire (RA739 or S865 AEx Suitable RD739) nA nR II for °C T6 T3 90 T5 T3 90 T5 T3 90 T6 T3 90 T5 T3 90 T5 T3 90 T6 T3 90 T5 T3 90 T4 T3 90 T5 T3 90 T4 T3 90 — T3 90 The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL 844 specifies how the temperatures are measured. The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2 locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844. *All DMVM 175W and below MH luminaires provided with Catalog number G303-S808 have a T2A T-code. †For use with refractor only when this table indicates by means of a T-code that the refractor is suitable for use with Class I, Division 2 luminaires. 986 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 986-987.qxp 12/16/2013 7:21 PM Page 987 Dimensions & Weights DMV Series 3L Champ® H.I.D. Luminaires Net Luminaire Weights (lbs.): Dimensions In Inches: Pendant Mount Quad-Mount Luminaire Series Lamp Watts Luminaire with Globe, Guard (lbs.) Lamp Watts Luminaire with Globe, Guard (lbs.) DMVS 50 100 23 241/16 70 150 231/16 261/8 DMVM 70 175 21 221/4 100 250 211/16 24 Type Lbs. Add for mounting modules: Pendant 11/4 Ceiling 23/4 Quad Mount 31/2 Straight Stanchion 41/2 Type Lbs. Flexible Pendant Wall Angle Stanchion 11/2 41/2 31/2 Add for reflectors: 30° Angle Dome 11/4 Deduct: 1 lb. for luminaire without P33 Guard. Add: 51/2 lbs. for luminaire with GR305 refractor. 25° Angle Stanchion Mount Straight Stanchion Mount Top View Ceiling Mount 13/4 3L Wall Mount Luminaire with Globe, Guard, Reflectors www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 987 988-989.qxp 12/16/2013 7:21 PM Page 988 Photometric Data DMV Series 3L Champ® H.I.D. Luminaires Lamp: 150W/E–23-1/2 clear high pressure sodium (HPS) Total bare lamp lumens: 16000 NOTE: All data provided is for high pressure sodium luminaires with 150W/E–23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Eaton's Crouse-Hinds for additional photometric data on any Champ series luminaires. Luminaire with Globe and Dome Reflector Multipliers (for use with candela curve only). ConLuminaire Lamp version Series Watts Factor 50 70 100 DMVS Isofootcandle Chart: Luminaire with Globe and Dome Reflector 0.25 0.40 0.59 Luminaire spacing ratio: 1.90 Coefficient of Utilization Effective Floor Cavity Reflectance 20% 3L % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .759 .719 .683 .643 .582 .530 .551 .480 .424 .476 .400 .342 .418 .340 .283 70 50 30 10 .740 .703 .669 .627 .570 .523 .538 .471 .418 .465 .394 .338 .406 .334 .280 50 50 30 10 .703 .672 .645 .595 .548 .506 .512 .455 .408 .442 .381 .332 .388 .324 .276 30 50 30 10 .669 .646 .622 .567 .528 .492 .488 .439 .399 .422 .368 .325 .370 .314 .270 10 50 30 10 .640 .619 .600 .541 .508 .479 .466 .424 .389 .403 .356 .318 .354 .305 .265 0 0 .582 .459 .370 % Reflectance Eff. Ceil. Wall .299 .247 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .371 .296 .243 .330 .257 .208 .294 .224 .174 .267 .198 .151 .231 .164 .121 70 50 30 10 .362 .291 .238 .323 .252 .204 .288 .221 .173 .262 .195 .151 .226 .164 .121 50 50 30 10 .345 .283 .235 .309 .244 .201 .275 .215 .170 .250 .190 .148 .218 .159 .119 30 50 30 10 .331 .275 .231 .294 .239 .196 .265 .208 .168 .240 .184 .146 .209 .154 .116 10 50 30 10 .317 .266 .227 .284 .233 .193 .253 .203 .165 .231 .180 .143 .201 .150 .114 0 0 .210 .177 .149 .128 .100 988 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 8 12 14 1.56 .694 .510 16 20 .391 .250 Copyright© 2013 Eaton’s Crouse-Hinds Business 988-989.qxp 12/16/2013 7:21 PM Page 989 VMV High Wattage Series 200-400W For Medium and High Mounting Heights Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (with Glass Refractor) Marine (with Globe or Glass Refractor) & Wet Locations 3, 3R, 4, 4X; IP66 Champ® H.I.D. Luminaires Applications: Standard Materials: VMV high wattage series Champ luminaires are used: • In manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, and other heavy industrial applications • In applications involving medium and high mounting heights • In applications where energy-efficient, high lumen output is required • In areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions • In marine applications where water spray and corrosive atmospheres are considerations • In elevated ambient temperatures often found in industrial applications • In installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems • Wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements, are problems • Ballast housings and mountings – copper-free aluminum (less than 0.4 of 1%) • Exterior hardware and guards – stainless steel • Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material • Globes – heat and impact resistant internally fluted glass • Refractors – glass • Reflector lens – spun Alzak aluminum, tempered glass, stainless steel door frame Features: Certifications and Compliances: • NEC/CEC: Class I, Division 2, Groups A, B, C, D With Glass Refractor - Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 • IEC: Zone 2 Ex nR IIC • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 www.crouse-hinds.com US: 1-866-764-5454 Standard Finishes: • • • • Copper-free aluminum – epoxy powder coat Alzak aluminum – natural Stainless steel – natural Krydon material – high reflectance white Options: The following special options are available from the factory by adding suffix to luminaire Cat. No.: Description Suffix • Restricted Breathing Construction................................... S826‡ Class I, Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) • Certified for IEC Zone 2.................................................... S826TB‡ Furnished with terminal block crimp terminals and dedicated voltage ballasts (no MT, DT, or TT) • Fused – to protect ballast and capacitors against abnormal line conditions (Not available with /MT ballast) (Not suitable for marine applications)................................ S658†* • Quick-Clip - Holds weight of housing when closed. No need to support luminaire while screwing the housing to the cover.......................................................... S890 • Quartz auxilliary lighting – comes to full brightness immediately and remains lit until the HID lamp attains 60–70% of full illumination. For non-hazardous locations only..................................................................................... QTZ • Ballast-Gard™ starter cutout switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 200–400W HPS only............................................................................ BG • Factory assembled with H.I.D. lamps installed for additional labor savings..................................................... FA • Top hat with stainless steel threaded insert to attach ballast housing................................................................... S806 Note: (Quartz lamp not included use 100W single ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC). Consult factory for top-hat limitations. Electrical Ratings: • 120 to 600 volts and multi-tap • 200, 250, 400W HPS and MH Accessories: • See pages 1022–1023 for complete listing. Alzak is a registered trademark of ALCOA. *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. †Not for use in Canada. ‡Suffix S826 and S826TB cannot be used with GRD4 Reflector/Lens. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 989 3L • Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion • Six mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket, angle stanchion, straight stanchion and quad-mount • Wide range of light sources and wattages to meet specifiers' needs: 200, 250, 400 watt high pressure sodium (HPS); 250 and 400 watt metal halide (MH) and pulse start metal halide • Hinged ballast housing for ease of installation and maintenance • Wide choice of photometric distributions. Glass globes, glass refractors, and reflector/lens are available • All luminaires designed to perform in a 40°C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C • Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments • Hubs with integral conduit stop and bushing to help prevent damage to field wiring during installation • Low ambient capability to (–40°C) • Dome and 30° angle reflectors made of bright white Krydon® material and etched Alzak® high bay reflectors provide superior reflectivity • Grounding wire for safety • High power factor ballasts (Min. P. F. 90%) are available in a variety of voltages to meet local area requirements • Mogul base lamp socket 3L 990-991.qxp 12/16/2013 7:23 PM Page 990 Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) 3L VMV High Wattage Series 200-400W High Pressure Sodium For Medium and High Mounting Heights Champ® H.I.D. Luminaires Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (with Glass Refractor) Marine (with Globe or Glass Refractor) & Wet Locations 3, 3R, 4, 4X; IP56 to IP66 To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Style Hub Size Lamp Watts With G303 Globe and P33 Guard With GR305 Glass Refractor * With GRD4 Reflector/Lens Pendant Mount (Rigid or Flexible) 3 /4 1 3 /4 1 3 /4 1 200 VMVS2A200GP VMVS3A200GP VMVS2A250GP VMVS3A250GP VMVS2A400GP VMVS3A400GP VMVS2A200GR305 VMVS3A200GR305 VMVS2A250GR305 VMVS3A250GR305 VMVS2A400GR305 VMVS3A400GR305 VMVS2A200GRD4 VMVS3A200GRD4 VMVS2A250GRD4 VMVS3A250GRD4 VMVS2A400GRD4 VMVS3A400GRD4 3 /4 1 /4 1 3 /4 1 200 3 250 VMVS2C200GP VMVS3C200GP VMVS2C250GP VMVS3C250GP VMVS2C400GP VMVS3C400GP VMVS2C200GR305 VMVS3C200GR305 VMVS2C250GR305 VMVS3C250GR305 VMVS2C400GR305 VMVS3C400GR305 VMVS2C200GRD4 VMVS3C200GRD4 VMVS2C250GRD4 VMVS3C250GRD4 VMVS2C400GRD4 VMVS3C400GRD4 3 /4 1 /4 1 3 /4 1 200 3 250 VMVS2TW200GP VMVS3TW200GP VMVS2TW250GP VMVS3TW250GP VMVS2TW400GP VMVS3TW400GP VMVS2TW200GR305 VMVS3TW200GR305 VMVS2TW250GR305 VMVS3TW250GR305 VMVS2TW400GR305 VMVS3TW400GR305 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 250 400 400 400 3 3 /4 /4 3 /4 200 250 400 VMVS25Q200GP VMVS25Q250GP VMVS25Q400GP VMVS25Q200GR305 VMVS25Q250GR305 VMVS25Q400GR305 VMVS25Q200GRD4 VMVS25Q250GRD4 VMVS25Q400GRD4 Stanchion Mount 25° Angle 11/2 11/2 11/2 200 250 400 VMVSJ200GP VMVSJ250GP VMVSJ400GP VMVSJ200GR305 VMVSJ250GR305 VMVSJ400GR305 VMVSJ200GRD4 VMVSJ250GRD4 VMVSJ400GRD4 Stanchion Mount Straight 11/2 11/2 11/2 200 250 400 VMVSP200GP VMVSP250GP VMVSP400GP VMVSP200GR305 VMVSP250GR305 VMVSP400GR305 3L Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVS2A200GR302 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVS2A200GR303 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT 120V /120 CEC/CSA (cUL) 480V /480 Tri Tap /TT 120V /120 220V 60Hz /220 220V 50Hz /220 50 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI EXPORT 600V CWI /600CWI 230V 50Hz /230 50 240V 50Hz /240 50 2. Options - Add the required option suffixes, see page 989, in alpha-numeric order. 990 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 990-991.qxp 12/16/2013 7:23 PM Page 991 VMV High Wattage Series 250400W Pulse Start Metal Halide For Medium and High Mounting Heights Champ® H.I.D. Luminaires Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (with Glass Refractor) Marine (with Globe or Glass Refractor) & Wet Locations 3, 3R, 4, 4X; IP56 to IP66 3L To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Style Hub Size Lamp Watts With G303 Globe and P33 Guard With GR305 Glass Refractor * Pendant Mount (Rigid or Flexible) 3 /4 1 3 /4 1 3 /4 1 250 VMVM2A250GP VMVM3A250GP VMVM2A320GP VMVM3A320GP VMVM2A400GP VMVM3A400GP S828 S828 S828 S828 S828 S828 VMVM2A250GR305 VMVM3A250GR305 VMVM2A320GR305 VMVM3A320GR305 VMVM2A400GR305 VMVM3A400GR305 S828 S828 S828 S828 S828 S828 VMVM2A250GRD4 VMVM3A250GRD4 VMVM2A320GRD4 VMVM3A320GRD4 VMVM2A400GRD4 VMVM3A400GRD4 S828 S828 S828 S828 S828 S828 3 /4 1 3 /4 1 3 /4 1 250 VMVM2C250GP VMVM3C250GP VMVM2C320GP VMVM3C320GP VMVM2C400GP VMVM3C400GP S828 S828 S828 S828 S828 S828 VMVM2C250GR305 VMVM3C250GR305 VMVM2C320GR305 VMVM3C320GR305 VMVM2C400GR305 VMVM3C400GR305 S828 S828 S828 S828 S828 S828 VMVM2C250GRD4 VMVM3C250GRD4 VMVM2C320GRD4 VMVM3C320GRD4 VMVM2C400GRD4 VMVM3C400GRD4 S828 S828 S828 S828 S828 S828 3 /4 1 3 /4 1 3 /4 1 250 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 320 400** 320 400** 320 400** VMVM2TW250GP VMVM3TW250GP VMVM2TW320GP VMVM3TW320GP VMVM2TW400GP VMVM3TW400GP S828 S828 S828 S828 S828 S828 With GRD4 Reflector/Lens VMVM2TW250GR305 VMVM3TW250GR305 VMVM2TW320GR305 VMVM3TW320GR305 VMVM2TW400GR305 VMVM3TW400GR305 S828 S828 S828 S828 S828 S828 3 3 /4 /4 3 /4 250 320 400** VMVM25Q250GP S828 VMVM25Q320GP S828 VMVM25Q400GP S828 VMVM25Q250GR305 S828 VMVM25Q320GR305 S828 VMVM25Q400GR305 S828 VMVM25Q250GRD4 S828 VMVM25Q320GRD4 S828 VMVM25Q400GRD4 S828 Stanchion Mount 25° Angle 11/2 11/2 11/2 250 320 400** VMVMJ250GP S828 VMVMJ320GP S828 VMVMJ400GP S828 VMVMJ250GR305 S828 VMVMJ320GR305 S828 VMVMJ400GR305 S828 VMVMJ250GRD4 S828 VMVMJ320GRD4 S828 VMVMJ400GRD4 S828 Stanchion Mount Straight 11/2 11/2 11/2 250 320 400** VMVMP250GP S828 VMVMP320GP S828 VMVMP400GP S828 VMVMP250GR305 S828 VMVMP320GR305 S828 VMVMP400GR305 S828 3L Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302-S828 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303-S828 ** To be used with ED28 (bulb shaped lamp). 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT 120V /120 Lamp Selection Table: CEC/CSA (cUL) 480V /480 Tri Tap /TT 230V 50Hz /230 50 240V 50Hz /240 50 Fixture Lamp Type Bulb 120V /120 Venture Phillips Sylvania MP 320W/BU/ED28/UVS/PS/EM/950 MS320/U/PS MS320/PS/BU-HOR MP 320W/BU/ED28/UVS/PS/740 MS320/C/BU/PS - MP 320W/C/BU/ED28/EVS/PS/737 - - Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage Suffix 220V 60Hz /220 220V 50Hz /220 50 VMVM320GP 320W PS MH ED28, BT28 2. Options - Add the required option suffixes, see page 989, in alpha-numeric order. VMVM400GP www.crouse-hinds.com 400W PS MH US: 1-866-764-5454 ED28, BT28 MP 400W/BU/ED28/UVS/PS/EM/950 N/A CAN: 1-800-265-0502 M400/PS/U/BT28 Copyright© 2013 Eaton’s Crouse-Hinds Business 991 992-993.qxp 12/16/2013 3L 7:23 PM Page 992 VMV High Wattage Series 250-400W Metal Halide Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 For Medium and High Mounting Heights (Suffix S826TB) ® Champ H.I.D. Luminaires Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (with Glass Refractor) Marine (with Globe or Glass Refractor) & Wet Locations 3, 3R, 4, 4X; IP56 to IP66 To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Hub Lamp With G303 Globe With GR305 Glass With GRD4 Style Size Watts and P33 Guard Refractor * Reflector/Lens Pendant Mount (Rigid or Flexible) Ceiling Mount Thru-Feed 3 /4 1 /4 1 250 3 400 /4 1 3 /4 1 250 /4 1 3 /4 1 250 3 Wall Mount Thru-Feed 400 3 400 VMVM2A250GP VMVM3A250GP N/A N/A VMVM2A250GR305 VMVM3A250GR305 VMVM2A400GR305 VMVM3A400GR305 VMVM2A250GRD4 VMVM3A250GRD4 VMVM2A400GRD4 VMVM3A400GRD4 VMVM2C250GP VMVM3C250GP N/A N/A VMVM2C250GR305 VMVM3C250GR305 VMVM2C400GR305 VMVM3C400GR305 VMVM2C250GRD4 VMVM3C250GRD4 VMVM2C400GRD4 VMVM3C400GRD4 VMVM2TW250GP VMVM3TW250GP N/A N/A VMVM2TW250GR305 VMVM3TW250GR305 VMVM2TW400GR305 VMVM3TW400GR305 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/2° Angle 3 /4 /4 250 400 VMVM25Q250GP N/A VMVM25Q250GR305 VMVM25Q400GR305 VMVM25Q250GRD4 VMVM25Q400GRD4 Stanchion Mount 25° Angle 11/2 250 VMVMJ250GP VMVMJ250GR305 VMVMJ250GRD4 11/2 400 N/A VMVMJ400GR305 VMVMJ400GRD4 11/2 11/2 250 400 VMVMP250GP N/A VMVMP250GR305 VMVMP400GR305 3L 3 Stanchion Mount Straight * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT 120V /120 CEC/CSA (cUL) 480V /480 Tri Tap /TT 120V /120 220V 60Hz /220 220V 50Hz /220 50 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI EXPORT 600V CWI /600CWI 230V 50Hz /230 50 240V 50Hz /240 50 2. Options - Add the required option suffixes, see page 989, in alpha-numeric order. 992 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 992-993.qxp 12/16/2013 7:23 PM Page 993 3L VMV High Wattage Series – Ordering by Components VMV High Wattage Luminaires are available in components. A complete luminaire consists of: I. II. III. Champ Cover (Mounting Module) VMV Ballast Housing – Include voltage and required option(s) Optical & Guard Components – Globe, Reflector, Refractor, Guard I. Champ Cover (Mounting Module): Type Pendant Conduit Cat. # 3 /4" 1" APM2 APM3 Ceiling 3 /4" 1" CM2 CM3 Wall 3 /4" 1" TWM2 TWM3 Stanchion – 25 Degree Angle 11/2" JM5 Stanchion – Straight 11/2" PM5 Quad-Mount 3 /4" QM25 II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Metal Halide Lamp Watts Cat. # 200 250 400 250 400 VMVS200/MT VMVS250/MT VMVS400/MT VMVM250/MT VMVM400/MT III. Globe, Reflectors, Refractors, Guards: Cat. # Globe G303 Globe Guard P33 Reflector – Dome RD739 Reflector – Angle RA739 Refractor – Type 2 GR302 Refractor – Type 3 GR303 Refractor – Type 5 GR305 Refractor Guard P23 High Bay Reflector/Lens GRD4 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 3L Type Copyright© 2013 Eaton’s Crouse-Hinds Business 993 994-995.qxp 3L 12/16/2013 7:23 PM Page 994 VMV High Wattage Series Family Tree 3L Champ® H.I.D. Luminaires 994 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 994-995.qxp 12/16/2013 7:23 PM Page 995 VMV High Wattage Series Temperature Performance Data 3L Champ® H.I.D. Luminaires High Pressure Sodium 200 40 55 65 325 C 350 C 325 C 350 C 325 C 350 C 250 40 55 65 400 40 55 T2 T2 T2 T3 T3 T3 T4 T4 – T3C – – T1/T3C – – T3C – – 75 75 85 350 C 350 C 325 C 350 C 350 C 350 C 350 C 350 C – T3 T3 T3 T4 T4 – T3C – – T1/T3C – – T3C – – 75 85 – 350 C 350 C 350 C 350 C T3 T3 T4 T4 T3C – T1/T3C – T3C – 85 90 T1 T1 Metal Halide 40 55 350 C 325 C 350 C 350 C 350 C 350 C T3 T3 T4 T4 T3B – 350 C/T3B – T3B – 85 90 250 40 55 350 C 325 C 350 C 350 C 350 C 350 C T3 T3 T4 T4 T3B – 350 C/T3B – T3B – 85 90 400 40 55 – – T4 – T3B – 350 C/T3B – T3B – 85 T3 T3 T4 T4 T3B – 350 C/T3B – T3B – 85 90 – – 325 C 350 C T1 T1 3L 200 – Pulse Start Metal Halide (S828) 250 40 55 350 C 350 C 325 C 350 C 350 C 350 C 320 40 T1 325 C T2A T3 – – – – 90 400 40 T1 T1 T1 T3 T4 – – – 90 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 995 996-997.qxp 12/16/2013 7:23 PM Page 996 VMV High Wattage Series 3L Dimensions & Weights Champ® H.I.D. Luminaires Dimensions In Inches: Pendant Mount Ceiling Mount Wall Mount 25° Angle Stanchion Mount Luminaire with Glass Refractor, Guard 3L Quad-Mount Luminaire with Etched Alzak Reflector/Lens Straight Stanchion Mount Luminaire with Globe, Guard, Reflectors Net Luminaire Weights (lbs.): Luminaire Series VMVS VMVM Lamp Watts 200 250 400 250 400 Luminaire with: Globe, Reflector/ Guard (lbs.) Lens 291/2 291/2 381/2 321/2 30 30 39 33 34 Type Lbs. Type Add for mounting modules: Quad-Mount Pendant 11/4 Angle Stanchion Ceiling 23/4 Straight Stanchion Wall 41/2 Add for reflectors: 30° Angle Dome 11/2 High Bay 13/4 Deduct: 11/2 lb. for luminaire without P33 Guard 996 www.crouse-hinds.com US: 1-866-764-5454 Glass Refractor (lbs.) 321/2 321/2 411/2 353/4 351/2 Lbs. 31/2 31/2 41/2 11/2 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 996-997.qxp 12/16/2013 7:23 PM Page 997 3L Photometric Data VMV High Wattage Series Champ® H.I.D. Luminaires Lamp: 250W/E–18 high pressure sodium (HPS) Total bare lamp lumens: 27500 Note: All data provided is for high pressure sodium luminaires with 250W/E–18 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Eaton's Crouse-Hinds for additional photometric data on any Champ series luminaire. Luminaire with Globe and Dome Reflector Multipliers (for use with candela curve only). ConLuminaire Lamp version Series Watts Factor VMVS 200 400 0.80 1.82 Luminaire spacing ratio: 2.0 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 5 50 30 10 .750 .711 .677 .640 .582 .532 .550 .482 .429 .476 .402 .346 .416 .341 .285 70 50 30 10 .732 .696 .664 .625 .570 .526 .538 .474 .424 .465 .397 .343 .405 .335 .282 50 50 30 10 .695 .666 .641 .594 .549 .509 .513 .458 .414 .443 .384 .336 .388 .326 .279 30 50 30 10 .663 .640 .618 .567 .530 .496 .490 .443 .405 .423 .372 .330 .371 .316 .273 10 50 30 10 .635 .615 .597 .542 .510 .483 .469 .429 .395 .405 .360 .323 .355 .307 .268 0 0 .580 .464 .377 .305 .251 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .369 .295 .243 .327 .255 .208 .290 .222 .173 .263 .196 .150 .229 .163 .121 70 50 30 10 .360 .291 .239 .320 .251 .204 .285 .219 .172 .258 .193 .149 .224 .163 .121 50 50 30 10 .344 .283 .236 .306 .243 .200 .272 .213 .170 .247 .189 .147 .216 .159 .119 30 50 30 10 .330 .275 .233 .292 .238 .196 .262 .207 .167 .238 .183 .145 .207 .154 .116 10 50 30 10 .317 .267 .229 .282 .233 .194 .251 .202 .165 .229 .179 .142 .200 .150 .114 0 0 .212 .178 .149 .128 .101 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 3L US: 1-866-764-5454 4 80 % Reflectance Eff. Ceil. Wall www.crouse-hinds.com Room Cavity Ratio 1 2 3 997 998-999.qxp 12/16/2013 7:24 PM Page 998 Luminaires with Induction Lighting System 3L Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Restricted Breathing Suffix S826 for CI. I, Div. 2 & Zone 2 VMVIG and DMVIG Series Enclosure Type 4X, IP66 Wet Locations Marine Locations UL and cUL Listed Get uninterrupted light for up to 11 years, without changing a lamp. Eaton's Crouse-Hinds Champ Luminaire with Induction Light Source delivers up to 100,000 hours of white light in a hazardous location, corrosion-resistant watertight package. That’s 5 to 8 times the typical life of conventional fluorescent or HID lamps. And, with no maintenance required for up to 11 years, you’ll reduce your maintenance and lamp replacement costs. Compelling reasons to choose the new Champ Induction Luminaire as the light source for industrial and hazardous locations include: • Crisp, white light (80+ color rendering index) provides increased safety by clearly illuminating signs, instrument panels, equipment and more with vibrant natural colors. • Up to 100,000 hours of lamp life minimizes routine maintenance costs. If you operate this luminaire for 24 hours, 7 days a week, you will not need to change the lamp for up to 11 years! • Instant illumination — no waiting for lamp warm-up time. Increases productivity and safety. • Delivers the best possible luminaire temperature rating — T6 (85°C) when used with the Champ restricted breathing option. Ideal for hazardous areas where a low ignition temperature is required. • Starts in low temperatures — as low as –40°C. 165W Champ Induction provides as much light as a 175W Metal Halide but lasts 7 times longer! Additional Features and Benefits: The Champ Induction Luminaire is suitable for Class I, Division 2 and Zone 2 areas with the assurance of Eaton's Crouse-Hinds quality and reliability. They are ideal for use in hard-to-reach applications and where process requirements demand continuous luminaire operation. 3L Features: • High lumens per watts (72 lpw for the 165W Champ) will save energy • Retains strong light output (retains more than 70% output) throughout the life of the lamp • Will not add electrical noise to the circuits — Total Harmonic Distortion is less than 10% • Excellent power factor of .96 increases useable watts to an excellent level and reduces energy consumption • Internal electronics are enclosed to ensure that there is no interference with external instrumentation 998 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 998-999.qxp 12/16/2013 7:24 PM Page 999 Luminaires with Induction Lighting System VMVIG and DMVIG Series with Lamps Included Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Restricted Breathing Suffix S826 for CI. I, Div. 2 & Zone 2 Enclosure Type 4X, IP66 Wet Locations Marine Locations UL and cUL Listed Applications: Options: Champ Induction Luminaires are ideal: • Where an extra long life lamp source (up to 100,000 hours) is required. • In areas that require lamps to reach full illumination immediately. • Where cool temperature ratings on the luminaire globe are needed to ensure safe operation in hazardous areas. • In hard-to-reach applications where relamping is costly. • Where luminaire maintenance is difficult due to continuous process operation requirements that restrict or prohibit shut down except in emergency situations. • To provide a cost-effective lighting system (low installed/life cost) by minimizing or even eliminating routine luminaire maintenance. • In cold environment applications. Description Restricted Breathing Construction Class I, Division 2 & Zone 2 suitability Cooler operating temperatures (T-Codes) Corrected color temperature lamp - 4000K Certifications and Compliances: • NEC & CEC: Class I, Division 2 and Zone 2 Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC • Restricted Breathing Suffix S826 for Class I, Division 2 and Zone 2 • Marine Locations, Wet Locations, Enclosure Type 3, 3R, 4, 4X; IP66 • UL and cUL Listed / ETL • UL Standards: 844, 60079-15, 1598, 1598A • CSA Standards: C22.2 No.137, E79 Series Compliances and approvals for the lamp system • • • • • RFI < 30 MHz RFI > 30 MHz Harmonics Immunity Safety • Performance • Vibration & bump tests Suffix S826 S887 Accessories: Mounting Modules Cat. # /4 NPT Pendant 1 NPT Pendant 3 /4 NPT Flexible Pendant 3 /4 NPT Ceiling Mount 1 NPT Ceiling Mount 3 /4 NPT Wall Mount 1 NPT Wall Mount 3 /4 NPT Quad Mount 11/2 NPT Stanchion Mount — 25 Degree Angle 11/2 NPT Stanchion Mount — Straight APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 QM25 JM5 PM5 3 Wattage Dome Reflector Cat. # Angle Reflector Cat. # 55W 85W 165W RD70 RD739 RD739 RA70 RA739 RA739 Dimensions: See Section 3L for dimensional information on VMV and DMV Series. Amperage: Power consumption for specific voltages 55W Luminaires a. 120VAC x .460mA = 55.70 watts b. 230VAC x .260mA = 59.80 watts 85W Luminaires c. 120VAC x .710mA = 85.20 watts d. 230VAC x .400mA = 92.00 watts 3L • Quality standards • Environmental standard EN 55015 EN 55022 EN 61000-3-2 EN 61547 EN 61347-2-3 & UL935 EN 60928 EN 60929 IEC 68-2-6-Fc IEC 68-2-29-Eb ISO 9001 ISO 14001 3L 165W Luminaires e. 120VAC x 1.35 = 162.00 watts f. 230VAC x .700mA = 161.00 watts Standard Materials: • Ballast housings and mountings – copper-free aluminum (less than 0.4 of 1%) • Exterior hardware – stainless steel • Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material • Globes – heat and impact-resistant internally fluted glass • Guards – copper-free aluminum (55W), stainless steel (85W) Standard Finishes: • Copper-free aluminum – epoxy powder coat • Krydon® material – high reflectance white • Stainless steel – natural www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 999 1000-1001.qxp 12/16/2013 3L 7:24 PM Page 1000 Luminaires with Induction Lighting System Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Restricted Breathing Suffix S826 for CI. I, Div. 2 & Zone 2 VMVIG and DMVIG Series Enclosure Type 4X, IP66 Wet Locations Marine Locations UL and cUL Listed Lamp Data: VMV DMV DMV 55 85 165 3500 6000 12000 Initial Mean Color Rendering Index* 65 70 72 51 57 58 80 80 80 Efficacy (LM/W) Lumen (LM) Initial Mean System Power (W) 2800 4800 9600 Lumen Maintenance After 60,000 Hrs (%) 75 75 70 *Lamp sources with 80+ CRI provide excellent color rendering. CRI scale is 0–100 with 100 considered as ideal. Temperature Performance Data: Cat. # Watts Ambient Temp. °C Supply Wire Temp. °C Class I, Div. 2 Temp. Rating Class II, Div. 1, Class III Temp. Rating VMVIG055 55 40 60 T2C – VMVIG055 55 55 75 T2C – DMVIG085 85 40 60 T3 T5 DMVIG085 85 55 75 T2D T4A DMVIG165 165 40 75 T3 – Champ Induction DMV 85 watt is now Class II, Div. 1 – suitable for dust environments. Simultaneous Presence Class I, Div. 2 – – T2D – – Restricted Breathing (Suffix S826) Aex nR IIC, Ex nR IIC Class I, Div. 2/Zone 2 T6 T5 T6 T5 T5 Ordering Information: To complete Catalog Number, add Voltage and Option suffix(es). Hub Size (Inches) 55W Induction Catalog Number (With G24 Globe & P21 Guard) 85W Induction Catalog Number (With G303 Globe & P33 Guard) 165W Induction Catalog Number (With G303 Globe & P33 Guard) Pendant /4 1 VMVIG2A055GP VMVIG3A055GP DMVIG2A085GP DMVIG3A085GP DMVIG2A165GP DMVIG3A165GP Flexible Pendant 3 /4 VMVIG2HA055GP DMVIG2HA085GP DMVIG2HA165GP /4 1 VMVIG2C055GP VMVIG3C055GP DMVIG2C085GP DMVIG3C085GP DMVIG2C165GP DMVIG3C165GP Wall Mount /4 1 VMVIG2TW055GP VMVIG3TW055GP DMVIG2TW085GP DMVIG3TW085GP DMVIG2TW165GP DMVIG3TW165GP Quad Mount 3 DMVIG25Q165GP Mounting Style 3 3 Ceiling Mount 3L 3 /4 VMVIG25Q055GP DMVIG25Q085GP Stanchion Mount 25° Angle 11/2 VMVIGJ055GP DMVIGJ085GP DMVIGJ165GP Stanchion Mount Straight 11/2 VMVIGP055GP DMVIGP085GP DMVIGP165GP Luminaire with Globe and Guard less Mounting Module — VMVIG055GP DMVIG085GP DMVIG165GP Add the voltage suffix to the above catalog number. Ex. - DMVIG2A085GP/120 Standard Voltage Suffix Range 120V, 50 / 60 Hz /120 Operative range of 108–132 VAC 200V–277V, 50 / 60 Hz /200 277 Operates on 208, 220, 230, 240, 277 VAC 1000 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1000-1001.qxp 12/16/2013 7:24 PM Page 1001 Luminaires with Induction Lighting System 3L Photometric Data VMVIG and DMVIG Series 55 Watt Induction Luminaire With Globe And Guard VMVIG055GP LAMP: 55W Induction 85 Watt Induction Luminaire With Globe And Guard DMVIG085GP LAMP: 85W Induction 3L Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon Lighting Layout Software are available to download. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1001 1002-1003.qxp 3L 12/16/2013 7:24 PM Page 1002 Luminaires with Induction Lighting System Photometric Data VMVIG and DMVIG Series 165 Watt Induction Luminaire With Globe DMVIG165G Lamp: 165W Induction 165 Watt Induction Luminaire With Globe And Guard 3L DMVIG165GP Lamp: 165W Induction Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon Lighting Layout Software are available to download. 1002 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1002-1003.qxp 12/16/2013 7:24 PM Page 1003 Luminaires with Induction Lighting System Photometric Data 3L VMVIG and DMVIG Series 165 Watt Induction Luminaire With Globe And RD739 Dome Reflector DMVIG165G Lamp: 165W Iinduction 165 Watt Induction Luminaire With Globe And RA739 (30° Angle) Reflector DMVIG165G Lamp: 165W Induction 3L Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon Lighting Layout Software are available to download. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1003 1004-1005.qxp 3L 12/16/2013 7:24 PM Page 1004 Luminaires with Induction Lighting System Family Tree 3L VMVIG and DMVIG Series 1004 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1004-1005.qxp 12/16/2013 7:24 PM Page 1005 N2MV Series 50-175W Non-metallic Champ® H.I.D. Luminaires Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Marine & Wet Locations 3, 3R, 4, 4X; IP56 3L Options: The following special options are available from the factory by adding suffix to luminaire Cat. No.: Certifications and Compliances: Features: Standard Materials: • Housing and mounting modules made of polyphenylene sulfide (PPS) for strength and maximum resistance to corrosion. • Pendant mounting module equipped with integral hub set screws for vibration resistance. • Hubs are provided with an integral bushing to help prevent damage to field wiring during installation and ground connection for positive bonding. • Guard, hub inserts, stanchion elbow and hardware made of stainless steel for maximum resistance to corrosion. • Grounding wire for safety. • Stainless steel open bottom guard permits direct access to the globe for easy relamping. • Hinged assembly allows the luminaire to hang free during installation to permit the use of both hands when wiring. • One external captive screw for ease of installation. • Handle – hinge assembly doubles as a handle for ease of installation, especially when carrying up a ladder. • Housing, mounting modules, component pallets – polyphenylene sulfide (PPS) • Guard, hub inserts, stanchion elbow, hardware – stainless steel • Globe – heat tempered • Gaskets – silicone rubber • NEC and CEC: Class I, Division 2, Groups A, B, C, D 100W Maximum – Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards C22.2 No. 137 Electrical Ratings: • 120, multi-tap/MT (120, 208, 240 and 277), Dual-Tap/DT (120, 277 volts), Tri-Tap/TT (120, 277, 347 volts) 480 volt, 600 volt, 220 / 240 volt-50 Hz • 50–150W HPS; 70–175W MH and Pulse Start MH www.crouse-hinds.com Description Suffix • Wall Mount Arm. For converting ceiling mount luminaire to a wall mount. ......................... N2MV-WM1 • Ballast-Gard™ starter cut-out switch. Prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50–150 watt – HPS ............. BG • Factory Assembled. For a factory assembled luminaire with lamp installed...................... FA • Instant Restrike. Enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. 50–150W LX HPS only.............. IR 50–100W LX HPS only.............. TIR • Quartz Auxiliary Lighting. Comes to full brightness immediately and remains lit until the HID lamp attains 60–70% of full illumination. For nonhazardous locations only. (Note: QTZ lamp not included; use 100W single ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC) Consult factory for top-hat limitations ................. QTZ • Fused. To protect ballast and capacitor against abnormal line conditions ................................... S658 (Not available with /MT ballast ) (Not for use in Canada) (Not suitable for marine applications) • Furnished with Lamps ................ S714 • Teflon® Coated Globe. For additional protection against breakage. For use with 50–100W HPS, 70–175W MH and pulse start MH ..................... S808 Accessories: • See pages 1022–1023 for complete listing. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1005 3L Applications: N2MV series Champ luminaires are used: • In areas in which ignitable concentrations of flammable gases or vapors will be present due to abnormal, unusual or accidental conditions. • In installations where moisture, dirt, vibration, corrosion or rough usage are concerns. • Wherever the damaging effects of water, wind, snow, sleet, hot sun or any combination of these elements are found. • Ideal for marine use; resists the harmful effects of salt water. • Withstands the harshest of corrosive environments. • To provide low wattage spot and floodlighting. • For general area lighting. • In areas where the ambient temperature will get as low as 40°C (–40°F). • In manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment facilities, offshore, dockside and harbor installations as well as other heavy industrial applications. 1006-1007.qxp 12/16/2013 3L 7:24 PM Page 1006 N2MV Series 50–150W High Pressure Sodium Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Non-metallic Champ® H.I.D. Luminaires Marine & Wet Locations 3, 3R, 4, 4X; IP56 To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page. Mounting Style Pendant Mount Ceiling Mount Thru-Feed Stanchion Mount 25° Angle Hub Size Lamp Watts /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 3 /4 1 11/2 11/2 11/2 11/2 50 3 70 100 150 50 70 100 150 50 70 100 150 BASIC CATALOG NUMBER With G303 Globe and With GR305 P33 Guard Glass Refractor * N2MVS2A050GP N2MVS3A050GP N2MVS2A070GP N2MVS3A070GP N2MVS2A100GP N2MVS3A100GP N2MVS2A150GP N2MVS3A150GP N2MVS2C050GP N2MVS3C050GP N2MVS2C070GP N2MVS3C070GP N2MVS2C100GP N2MVS3C100GP N2MVS2C150GP N2MVS3C150GP N2MVSJ050GP N2MVSJ070GP N2MVSJ100GP N2MVSJ150GP N2MVS2A050GR305 N2MVS3A050GR305 N2MVS2A070GR305 N2MVS3A070GR305 N2MVS2A100GR305 N2MVS3A100GR305 N2MVS2A150GR305 N2MVS3A150GR305 N2MVS2C050GR305 N2MVS3C050GR305 N2MVS2C070GR305 N2MVS3C070GR305 N2MVS2C100GR305 N2MVS3C100GR305 N2MVS2C150GR305 N2MVS3C150GR305 N2MVSJ050GR305 N2MVSJ070GR305 N2MVSJ100GR305 N2MVSJ150GR305 * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVS2A050GR302 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVS2A050GR303 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT Dual Tap /DT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT Dual Tap /DT 600V CWI /600CWI 220V 60Hz /220 220V 50Hz /220 50 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI 120V /120 EXPORT 230V 50Hz /230 50 240V 50Hz /240 50 2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps - add suffix CE. 50W HPS luminaire is dual tap only. 3L 3. Options - Add the required option suffixes, see page 1005, in alpha-numeric order. 1006 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1006-1007.qxp 12/16/2013 7:24 PM Page 1007 N2MV Series 150–175W Pulse Start Metal Halide Non-metallic Champ® H.I.D. Luminaires Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Marine & Wet Locations 3, 3R, 4, 4X; IP56 3L To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see N2MV Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Style Pendant Mount Ceiling Mount Thru-Feed Hub Size Lamp Watts With G303 Globe and P33 Guard * With GR305–S828 Glass Refractor 3 /4 1 3 /4 1 150 N2MVM2A150GP N2MVM3A150GP N2MVM2A175GP N2MVM3A175GP S828 S828 S828 S828 N2MVM2A150GR305 N2MVM3A150GR305 N2MVM2A175GR305 N2MVM3A175GR305 S828 S828 S828 S828 3 /4 1 3 /4 1 150 N2MVM2C150GP N2MVM3C150GP N2MVM2C175GP N2MVM3C175GP S828 S828 S828 S828 N2MVM2C150GR305 N2MVM3C150GR305 N2MVM2C175GR305 N2MVM3C175GR305 S828 S828 S828 S828 Stanchion Mount 11/2 25° Angle 11/2 175 175 150 175 N2MVMJ150GP S828 N2MVMJ175GP S828 N2MVMJ150GR305 S828 N2MVMJ175GR305 S828 * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A150GR302-S828 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A150GR303-S828 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT 230V 50Hz /230 50 240V 50Hz /240 50 120V /120 Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage Suffix 220V 60Hz /220 220V 50Hz /220 50 2. Options - Add the required option suffixes, see page 1005, in alpha-numeric order. 3L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1007 1008-1009.qxp 12/23/2013 3L 3:12 PM Page 1008 N2MV Series 70–175W Metal Halide Cl. I, Div. 2, Groups A, B, C, D Cl. II, Groups F, G Cl. III & Simultaneous Presence (100W max) Non-metallic Champ® H.I.D. Luminaires Marine & Wet Locations 3, 3R, 4, 4X; IP56 To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Style Pendant Mount Ceiling Mount Thru-Feed Stanchion Mount 25° Angle Hub Size Lamp Watts With G303 Globe and P33 Guard With GR305 Glass Refractor * 3 /4 1 3 /4 1 3 /4 1 70 N2MVM2A070GP N2MVM3A070GP N2MVM2A100GP N2MVM3A100GP N2MVM2A175GP N2MVM3A175GP N2MVM2A070GR305 N2MVM3A070GR305 N2MVM2A100GR305 N2MVM3A100GR305 N2MVM2A175GR305 N2MVM3A175GR305 3 /4 1 3 /4 1 3 /4 1 70 N2MVM2C070GP N2MVM3C070GP N2MVM2C100GP N2MVM3C100GP N2MVM2C175GP N2MVM3C175GP N2MVM2C070GR305 N2MVM3C070GR305 N2MVM2C100GR305 N2MVM3C100GR305 N2MVM2C175GR305 N2MVM3C175GR305 11/2 11/2 11/2 70 100 175 N2MVMJ070GP N2MVMJ100GP N2MVMJ175GP N2MVMJ070GR305 N2MVMJ100GR305 N2MVMJ175GR305 100 175 100 175 * For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A070GR302 For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A070GR303 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts – 60Hz NEC/UL Voltage Suffix Multi Tap /MT 120V /120 CEC/CSA (cUL) 480V /480 Tri Tap /TT 120V /120 220V 60Hz /220 220V 50Hz /220 50 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts 3L Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI EXPORT 600V CWI /600CWI 230V 50Hz /230 50 240V 50Hz /240 50 2. 70W ballast not available in 480V. 3. Options - Add the required option suffixes, see page 1005, in alpha-numeric order. 1008 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1008-1009.qxp 12/23/2013 3:12 PM Page 1009 N2MV Series – Ordering by Components 3L N2MV luminaires are available in components. A complete luminaire consists of: I. N2MV Cover (Mounting Module) II. N2MV Ballast Housing – Include voltage and required option(s) III. Globe, Refractor, Guard, Reflector I. N2MV Cover (Mounting Module): Type Pendant Conduit Cat. # 3 /4" 1" N2APM2 N2APM3 Ceiling 3 /4" 1" N2CM2 N2CM3 Wall (Use wall bracket accessory with Ceiling Cover) Stanchion – 25 Degree Angle 3 /4" 1" N2MV WM1 and N2CM2 N2MV WM1 and N2CM3 11/2" N2JM5 II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Lamp Type Watts Cat. # High Pressure Sodium 50 N2MVS050/MT 70 N2MVS070/MT 100 N2MVS100/MT 150 N2MVS150/MT LX Metal Halide 70 100 175 N2MVM070/MT N2MVM100/MT N2MVM175/MT III. Globe, Refractors, Guards and Reflectors: Cat. # Globe Globe Teflon Coated Globe Guard Reflector – Dome Reflector – Angle Refractor – Type 2 Refractor – Type 3 Refractor – Type 5 Refractor Guard Large Plastic Refractor Type 2 Large Plastic Refractor Type 3 Large Plastic Refractor Type 5 G303 3L Type G303S808 P33 RD739 RA739 GR302 GR303 GR305 P23 PGR302 PGR303 PGR305 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1009 1010-1011.qxp 3L 12/16/2013 7:25 PM Page 1010 N2MV Series Family Tree Champ® H.I.D Luminaires 3L *Plastic refractors are non-hazardous areas only (50-100W Max.) 1010 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1010-1011.qxp 12/16/2013 7:25 PM Page 1011 N2MV Series 3L Temperature Performance Data Champ® H.I.D Luminaires High Pressure Sodium 40 55 50 65 T3A T3A – T4A – – 75 85 – 75 85 – 40 55 65 T3A T3A – T4A – – 100 40 55 65 T2D T2C – T4A – – T2C/T4A – – 85 100 – 150 40 55 65 T2C – – – – – – – – 85 – – 70 40 55 65 T3C T3B – T4 – – T2B/T4 – – 75 85 – 100 40 55 65 T2B T2B – T4 – – T2B/T4 – – 85 – – 150 (S828) 40 55 65 T2 – – – – – – – – – – – 175 (Includes S828) 40 55 65 T2 – – – – – – – – – – – 3L 70 T2C/T4A – – T2C/T4A – – Metal Halide www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1011 1012-1013.qxp 12/16/2013 3L 7:25 PM Page 1012 N2MV Series Dimensions and Weights Champ® H.I.D. Luminaires Dimensions In Inches: Ceiling Mount 3L Ceiling Mount – Top View Pendant Mount 25° Angle Stanchion Mount Net Luminaire Weights (lbs.): Luminaire Series Lamp Watts Luminaire with Globe, Guard (lbs.) Lamp Watts Luminaire with Globe, Guard (lbs.) N2VMS 50 100 23 241/16 70 150 231/16 261/8 N2MVM 70 175 21 221/4 100 250 211/16 24 Type Lbs. Add for mounting modules: Pendant 11/4 Ceiling 23/4 Quad-Mount 31/2 Straight Stanchion 41/2 www.crouse-hinds.com US: 1-866-764-5454 Lbs. Flexible Pendant Wall Angle Stanchion 11/2 41/2 31/2 Add for reflectors: 30° Angle Dome 11/ 4 Deduct: 1 lb. for luminaire without P33 Guard. 1 Add: 5 / 2 lbs. for luminaire with GR305 refractor. Wall Arm Mount 1012 Type CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 13/4 1012-1013.qxp 12/16/2013 7:25 PM Page 1013 N2MV Series 3L Photometric Data Champ® H.I.D Luminaires Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS) Total bare lamp lumens: 16000 All data provided is for high pressure sodium luminaires with 150W/E-23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Eaton's Crouse-Hinds for additional photometric data on any Champ series luminiares. Luminaire with Globe and Dome Reflector Multipliers (for use with candela curve only). Luminaire Series Lamp Watts Conversion Factor N2MVS 50 70 100 0.25 0.40 0.59 Isofootcandle Chart: Luminaire with Globe and Dome Reflector Luminaire spacing ratio: 1.90 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 4 5 80 50 30 10 .759 .719 .683 .643 .582 .530 .551 .480 .424 .476 .400 .342 .418 .340 .283 70 50 30 10 .740 .703 .669 .627 .570 .523 .538 .471 .418 .465 .394 .338 .406 .334 .280 50 50 30 10 .703 .672 .645 .595 .548 .506 .512 .455 .408 .442 .381 .332 .388 .324 .276 30 50 30 10 .669 .646 .622 .567 .528 .492 .488 .439 .399 .422 .368 .325 .370 .314 .270 10 50 30 10 .640 .619 .600 .541 .508 .479 .466 .424 .389 .403 .356 .318 .354 .305 .265 0 0 .582 .459 .370 .299 .247 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .371 .296 .243 .330 .257 .208 .294 .224 .174 .267 .198 .151 .231 .164 .121 70 50 30 10 .362 .291 .238 .323 .252 .204 .288 .221 .173 .262 .195 .151 .226 .164 .121 50 50 30 10 .345 .283 .235 .309 .244 .201 .275 .215 .170 .250 .190 .148 .218 .159 .119 30 50 30 10 .331 .275 .231 .294 .239 .196 .265 .208 .168 .240 .184 .146 .209 .154 .116 10 50 30 10 .317 .266 .227 .284 .233 .193 .253 .203 .165 .231 .180 .143 .201 .150 .114 0 0 .210 .177 .149 .128 .100 % Reflectance Eff. Ceil. Wall www.crouse-hinds.com US: 1-866-764-5454 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector 3L Room Cavity Ratio 1 2 3 Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 8 12 14 1.56 .694 .510 16 20 .391 .250 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1013 1014-1015.qxp 12/16/2013 3L 7:25 PM Page 1014 NVMV Series 70-400W Ex-Protected Luminaire for IEC and ATEX Applications Champ® H.I.D. Luminaires The Champ® NVMV design is optimized for Zone 2 gas applications (with standard restricted breathing Ex nR protection), as well as Zone 21 dust applications. Applications: NVMV Ex-Protected Luminaires are suitable for applications in Zone 2/Zone 21/Zone 22: • In manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, dockside and other heavy industrial applications • In areas where combustible dusts or fibers may be present • In areas where ignitable concentrations of flammable gases or vapors will be present • In installations where moisture, dirt, dust, vibration, corrosion, and rough usage are problematic 3L Features: • One product offering for global applications. The Champ family has the required IEC and ATEX certifications to provide solutions for specification requirements around the world. • Restricted breathing (Ex nR) protection is standard. This provides better T-ratings, as gases will not enter the lamp chamber and control gear housing. • Provides an integrated ballast with thermal cut-off functionality incorporated into the control gear. In the event of abnormal temperatures or when the lamp approaches end of life, the cut-off functionality protects the ballast from overheating or burning out. • Identical mounting cover for IEC and NEC applications - regardless of wattage, options, and accessories. Reduce inventory costs and provide greater flexibility for engineering designers, customers, and distributors. • HPS lamps restrike in 10-30 seconds with the instant restrike option (IR) should lamp extinguish due to system voltage drop or momentary loss. Optional builtin cut-off feature will shut off the instant restrike to avoid continuous high energy pulsing when lamp is inoperative or nearing end of life. • Available with the Champ Quick-Clip. Quick-Clip secures the housing to the cover, providing faster, easier, and safer luminaire installation. 1014 www.crouse-hinds.com US: 1-866-764-5454 Ex nR II T...Gc Ex t IIIC T...°C Db IP66 LCIE 09 ATEX 1002 LCIE 09 ATEX 3008 Certifications and Compliances: Application in Zone 2 area acc. IEC 60079-15 • Marking to 94/9/EC: Ex II 3 G Ex nR II T*...Gc • EC - Type Examination: LCIE 09 ATEX 1002 Application in Zone 21 and 22 areas acc. IEC 61241-1 • Marking to 94/9/EC: Ex II 2 D Ex t IIIC T...ºC(*) Db IP66 • EC - Type Examination: LCIE 09 ATEX 3008 General per both application Zone 2 and 21 • Temperature ambient of use: -45ºC to +55ºC • Electromagnetic compatibility: EN 61000-6-4 • Degree of protection: acc. EN 60529 IP66 NVMV 70W - 250W (Small Housing) Standard Materials and Finishes: • Ballast housing and mountings – copper-free aluminum • Exterior hardware – stainless steel (type 304) • Reflectors (dome and angle) – Krydon® fiberglass-reinforced polyester • Globes – heat and impact-resistant glass • Guards – copper-free aluminum and stainless steel (large housing - stainless steel only) NVMV 250W - 400W (Large Housing) Technical Specifications: • Entry • Termination • Installation • Lamp Holder • Lamp Type • Lamp Power • Control Gear • • • • Re-lamping Burning Position Ingress Protection Electrical Supply CAN: 1-800-265-0502 Up to 4 x M20, M25, M32, 1/ 2" NPT and 3/ 4" NPT and 1" NPT cable entries (11/ 2" NPT for stanchion only) 3 Core 6mm2 max. (standard); 6 x 6mm2 for looping (available upon request) Ceiling Mount, Wall Mount, Stanchion Mount, Pendant Mount E27 or E40 HSE/HST (high pressure sodium lamp) and HIE (metal halide lamp) 70W, 100W, 150W, 250W, and 400W Integrated ballast, thermal cut-off functionality incorporated into control gear Access via restricted breathing lamp chamber Base up; up to 25° off vertical IP66 to EN 60529 220, 230, 240V 50Hz and 220, 230V 60Hz Copyright© 2013 Eaton’s Crouse-Hinds Business 1014-1015.qxp 12/16/2013 7:25 PM Page 1015 NVMV Series 70-400W Ex-Protected Luminaire for IEC and ATEX Applications 3L Ex nR II T...Gc Ex t IIIC T...°C Db IP66 LCIE 09 ATEX 1002 LCIE 09 ATEX 3008 Champ® H.I.D. Luminaires Ordering Information: Example of Completed Part Number - Small Body: NVMVS1MC075POO NVMV Series S Lamp NVMV S = HSE/HST Luminaire (HPS) IEC Gear M = HIE (MH) 1M Entry C Mounting* 07 5 Wattage Voltage 1M = M20 2M = M25 3M = M32 1N = 1/2" NPT 2N = 3/4" NPT 3N = 1" NPT 5N = 1 1/2" NPT (For Stanchion) C = Ceiling W = Wall J = Stanchion 07 = 70W 10 = 100W 15 = 150W 25 = 250W 3 5 6 4 7 = = = = = 220V 230V 240V 220V 230V / / / / / 50 50 50 60 60 Hz Hz Hz Hz Hz P Guard O Body O O = Without Guard G34 Globe P = G251 Globe with P22 Alum. Guard S = G251 Globe with P22 SS304 Guard O = Small Body O = Standard P Guard L Body O Example of Completed Part Number - Large Body: NVMVS1MC255PLO NVMV Series S Lamp NVMV S = HSE/HST Luminaire (HPS) IEC Gear M = HIE (MH) C Mounting* 25 5 Wattage Voltage 1M = M20 2M = M25 3M = M32 1N = 1/2" NPT 2N = 3/4" NPT 3N = 1" NPT 5N = 1 1/2" NPT (For Stanchion) C = Ceiling W = Wall J = Stanchion 25 = 250W 40 = 400W 3 5 6 4 7 = = = = = 220V 230V 240V 220V 230V / / / / / 50 50 50 60 60 Hz Hz Hz Hz Hz O = Without L = Large Body Guard G303 Globe P = G303 Globe with P33 SS Guard O = Standard 3L 1M Entry Options and Accessories: Description Suffix Instant restrike (100W HPS and 150W HPS) (alternative solution to dual arc lamps) /IR Dome reflector - small housing /RD70 30° angle reflector - small housing /RA70 Dome reflector - large housing /RD739 30° angle reflector - large housing /RA739 Champ® Quick-Clip /S890 *For pendant mounting, order ceiling mount with pendant bracket accessory - please consult factory. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1015 1016-1017.qxp 12/16/2013 3L 7:26 PM Page 1016 NVMV Series Temperature Performance Data Champ® H.I.D. Luminaires Temperature Performance: Refer to temperature performance data tables (below) to select luminaire that is suitable for your area specifications. These numbers are the maximum surface temperature of the luminaire. Note: T3 - maximum surface temperature 200°C T4 - maximum surface temperature 135°C For example: atmospheres that contain gasoline and have an ignition temperature of 536°C, any fixture with the T-rating in this table can be used. Atmospheres that contain diethyl ether and have an ignition temperature of 160°C require a luminaire with T4 ratings. NVMV 70W - 250W (Small Housing) GAS (Class I, Zone 2) Ex nR II T...Gc Catalog Number Example† Watts NVMVS1MC075*00 70W NVMVS1MC105*00 100W Lamp Type Rated Lamp With Ambient Holder G34 °C Globe Only HSE/HST (HPS) NVMVS1MC155*00 150W NVMVS1MC255*00 250W NVMVM1MC075*00 70W NVMVM1MC105*00 100W NVMVM1MC155*00 150W NVMVM1MC255*00 250W 3L HIE (MH) 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 40 50 55 T4 T4 T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 T4 T4 T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 E27 E40 E40 E40 E27 E27 E27 E40 With G251 Globe Only T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 T3 T3 T4 T4 T4 T4 T4 T3 T3 T3 T3 T3 T2 T2 DUST (Class II, Zone 21) Ex t IIIC T...Db With With With G34 G251 G34 Globe Globe Globe and and Only Reflector Reflector T4 T4 99°C T4 T4 109°C T4 T4 114°C T4 T4 99°C T4 T3 109°C T4 T3 114°C T3 T3 122°C T3 T3 132°C T3 T3 137°C T3 T2 168°C T2 T2 178°C T2 T2 183°C T4 T4 99°C T4 T4 109°C T4 T4 114°C T4 T4 99°C T4 T3 109°C T4 T3 114°C T3 T3 122°C T3 T3 132°C T3 T3 137°C T3 T2 168°C T2 T2 178°C T2 T2 183°C With G251 Globe Only 109°C 119°C 124°C 117°C 127°C 132°C 140°C 150°C 155°C 174°C 184°C 189°C 109°C 119°C 124°C 117°C 127°C 132°C 140°C 150°C 155°C 194°C 204°C 209°C With With G34 G251 Globe Globe and and Reflector Reflector 104°C 109°C 114°C 119°C 119°C 124°C 104°C 128°C 114°C 138°C 119°C 143°C 140°C 140°C 150°C 150°C 155°C 155°C 189°C 218°C 199°C 228°C 204°C 233°C 104°C 109°C 114°C 119°C 119°C 124°C 104°C 128°C 114°C 138°C 119°C 143°C 140°C 140°C 150°C 150°C 155°C 155°C 189°C 218°C 199°C 228°C 204°C 233°C †Cat. No. - shown with M20 Ceiling Mount, /230V, 50 Hz. NVMV 250W - 400W (Large Housing) Catalog Number Example Watts NVMVS1MC255*L0 250W NVMVS1MC405*L0 400W NVMVM1MC255*L0 250W NVMVM1MC405*L0 400W 1016 www.crouse-hinds.com Lamp Type Rated Ambient °C HSE/HST (HPS) 40 50 55 40 50 55 HIE (MH) 40 50 55 40 50 55 US: 1-866-764-5454 Lamp Holder E40 E40 E40 E40 CAN: 1-800-265-0502 GAS (Class I, Zone 2) Ex nR II T...Gc With G303 With G303 Globe Only Globe and Reflector DUST (Class II, Zone 21) Ex t IIIC T...Db With G303 With G303 Globe Only Globe and Reflector T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 137°C 147°C 152°C 159°C 169°C 174°C 137°C 147°C 152°C 175°C 185°C 190°C T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T2 T2 137°C 147°C 152°C 159°C 169°C 174°C 137°C 147°C 152°C 193°C 203°C 208°C Copyright© 2013 Eaton’s Crouse-Hinds Business 1016-1017.qxp 12/16/2013 7:26 PM Page 1017 NVMV Series 3L Dimensions & Weights Champ® H.I.D. Luminaires Dimensions: 3L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1017 1018-1019.qxp 3L 12/16/2013 7:26 PM Page 1018 NVMV Series Photometric Data Champ® H.I.D. Luminaires 3L Photometry - Large Housing: 1018 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1018-1019.qxp 12/16/2013 7:26 PM Page 1019 3L Photometric Data NVMV Series Champ® H.I.D. Luminaires Photometry - Large Housing: 3L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1019 1020-1021.qxp 3L 12/16/2013 7:26 PM Page 1020 NVMV Series Photometric Data Champ® H.I.D. Luminaires 3L Photometry - Small Housing: 1020 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1020-1021.qxp 12/16/2013 7:27 PM Page 1021 NVMV Series 3L Photometric Data Champ® H.I.D. Luminaires Photometry - Small Housing: 3L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1021 1022-1023.qxp 12/16/2013 7:27 PM Page 1022 Accessories Champ® H.I.D. Luminaires 3L VMV, LMV, DMV, VMV High Wattage & N2MV Series Globes Reflectors Dome – Krydon® material G54 G24 Lamp Watts Luminaire Series Type 35–150 50–175 50–250 200–400 50–175 LMV VMV DMV VMV N2MV Heat/impact Heat/impact Heat/impact Heat/impact Heat/impact 30° Angle – Krydon material G303 Cat. # resistant resistant resistant resistant resistant G54 G24 G303 G303 G303 Lamp Watts Luminaire Series Dome Cat. # Angle Cat. # 35–150 50–175 50–250 200–400 50–175 LMV VMV DMV VMV N2MV RD636 RD70 RD739 RD739 RD739 RA636 RA70 RA739 RA739 RA740 Reflector / Lens Guards Etched Alzak aluminum reflector/tempered glass lens P50 – use with G54 globe P21 – use with G24 globe P33 – use with G303 globe Lamp Watts Luminaire Series Type Cat. # 200–400 70–250 VMV DMV Reflector/Lens Reflector/Lens GRD4 GRD4 3L Globes – Teflon Coated Teflon coated for increased shatter protection Lamp Watts Luminaire Series Cat. # 50–175 50–175 VMV DMV G24 S808 G303 S808 Alzak is a registered trademark of Alcoa. Teflon is a registered trademark of E.I. DuPont Co. P23 – use with refractors Lamp Watts Luminaire Series Type Cat. # 35–150 50–175 50–250 200–400 Refractors 50–175 LMV VMV DMV VMV All N2MV Copper-free aluminum Copper-free aluminum Stainless steel Stainless steel Stainless steel Stainless steel P50 P21 P33 P33 P23 P33 1022 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1022-1023.qxp 12/16/2013 7:27 PM Page 1023 Champ® H.I.D. Luminaires Accessories 3L VMV, LMV, DMV, VMV High Wattage & N2MV Series Refractors Safety Lighting Options Description Suffix Quartz Auxiliary Lamp QTZ The quartz auxiliary lamp comes to full brightness instantly and remains lit until the H.I.D. lamp attains 60–70% of full illumination. Quartz auxiliary lamps can be used with all DMV, VMV and VMV High Wattage series Champ® luminaires. Use for non-hazardous applications ONLY. VMV luminaires (50–175W) ordered with this option must use large glass refractor optics, not compact refractors. R2, R5, PR2, PR3, PR5 GR302, GR303, GR305 Luminaire Series I.E.S. Type Glass Cat. # Plastic (100W max. non-hazardous)* Cat. # 50–175 VMV II III V R2 R3 R5 PR2 PR3 PR5 200–400 VMV II III V GR302 GR305 GR305 50–250 DMV II III V GR302 GR303 GR305 50–175 N2MV Lamp Watts 100W single ended lamp – Q100CL/DC, Q100DC or 100Q/CL/DC NOT furnished Instant Restrike Factory installed instant restrike device will restart a hot High Pressure Sodium lamp after a momentary power interruption, without the typical delay for cooling. For use in 50–150W "LX" HPS luminaires. IR For use in 50–100W "LX" HPS luminaires. PGR302 PGR303 PGR305 TIR Ballast-Gard™ BG Ballast-Gard starter cut-out switch prevents starter pulsing after a time delay of approximately two minutes if the lamp fails to start. For use in 50–400 watt HPS luminaires only. *Not available with VMV fluorescent. I.E.S. Distribution Curves 3L Type I Type II Type III Type V Luminaire Series I.E.S. Type Glass Cat. # VMV I III V G241 G243 G245 P241 Compact Refractors Lamp Watts 50–175 Optional stainless steel wire guard www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1023 1024-1025.qxp 12/16/2013 3L 7:27 PM Page 1024 Cl. I, Div. 2, Groups A, B, C, D Maintains Cl. I, Div. 2 Suitability of Eaton's Crouse-Hinds Champ® Series Luminaires Photocells V2PC, D2S and EV2IH Series The only UL recognized photocells for Class I, Division 2 areas. Eliminates the need for an explosionproof box! Eaton's Crouse-Hinds factory-sealed, field installed photocells offer reliable, dusk-to-dawn lighting control in Class I, Division 2 locations. These photocells are ideal for walkways, security lighting, and any other outdoor lighting application that utilizes Champ® H.I.D. lighting luminaires. Applications: Eaton's Crouse-Hinds photocells are designed: • To provide control for automatic dusk-to-dawn lighting. • For safety by turning on outdoor luminaires in critical passageways at night. • To save energy by operating luminaires only when necessary. • For walkways, parking areas, outdoor process areas, security lighting, or any outdoor lighting application in Class I, Division 2 locations and corrosive environments. Certifications and Compliances: • For use with LMV, DMV, VMV, VMV High Wattage, and FMV Series Champ® lighting luminaires (V2PC Series). • For use on 35–400 watt H.I.D., incandescent, or fluorescent lighting luminaires. Class I, Division 2, Groups A, B, C, D • For remote mounting in FS boxes (D2S Series). • UL Standard: 844 – Hazardous (Classified) Locations • For mounting in EIH enclosures for Class I, Division 1 applications (EV2IH Series). • CSA: C22.2 No. 55 Features: EV2IH Series • NEC/CEC: Class I, Division 1 and 2, Groups B, C, D • Field-installable. Class II, Division 1, Groups E, F, G • Solid-state design for performance and dependability. Class II, Division 2, Groups F, G • Factory sealed components. Explosionproof enclosure not required for Class I, Division 2 locations. 3L V2PC Series and D2S Series • NEC/CEC: Class III • NEMA: 3, 4, 7BCD, 9EFG • Luminaires turn on at 3 footcandles, off at 8 footcandles insuring that the luminaires are operating only when needed. • UL Standard: 844 – Hazardous (Classified) Locations • CSA: C22.2 No. 30, 55 • Built-in 10 second time delay to eliminate nuisance tripping. • Eight-year operating life. Electrical Rating Ranges: • Furnished with 6" stranded 600 volt color coded wire leads. • 120, 208, 220, 240, 277 VAC • Constructed from corrosion-resistant thermoplastic polyester. • 50 / 60 Hz • Available on a DS cover for use with any FS/FD box (D2S Series). • 35–400 watt H.I.D., incandescent, or fluorescent • Available in an EIH enclosure for use in Class I, Division 1, Groups B*, C, and D locations (EV2IH Series). No seals required. • V2PC20 – 3.3A max. current rating • V2PC22 – 1.8A max. current rating *For Group B applications, seal within 11/2" of enclosure in accordance with Section 501-5 of the National Electric Code®. 1024 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 • V2PC27 – 1.4A max. current rating Copyright© 2013 Eaton’s Crouse-Hinds Business 1024-1025.qxp 12/16/2013 7:27 PM Page 1025 Photocells Cl. I, Div. 2, Groups A, B, C, D Maintains Cl. I, Div. 2 Suitability of Eaton's Crouse-Hinds Champ® Series Luminaires 3L V2PC, D2S and EV2IH Series Ordering Information: Photocell for field installation in lighting fixtures* Cat. # Voltage Range Current Rating V2PC20 V2PC22 V2PC27 120V, 50/60Hz 208–240V, 50/60Hz 277V, 50/60Hz 3.3A 1.8A 1.4A Photocell in DS cover for use with FS/FD box Cat. # Voltage Range D2S20 D2S208 277 120V, 50/60Hz 208V-277V Photocell in EIH enclosure for use in Class I, Division 1, Groups B, C, and D; Class II, Division 1, Groups E, F, and G; and Class III locations Cat. # Voltage Range EV2IH20 EV2IH208 277 120V, 50/60Hz 208-277V 50/60Hz 3L Replacement Photocell for D2S Cover or EIH Enclosure * † Cat. # Voltage Range Current Rating V2PCT20 V2PCT208 277 120V, 50/60Hz 208V-277V 50/60Hz 8.33A 4.81A - 3.61A depending on voltage * Must be factory installed in Canada. † When mounting in EIH enclosures for Class I, Division 1 applications (EV21H Series) seals are not required for Groups C & D. Options: To order luminaire with photocell factory installed: 1. Specify luminaire dedicated supply voltage (not MT, DT, or TT) 2. Add photocell Cat. No. to fixture Cat. No. as follows: V2PC20 V2PC22 V2PC27 Example: VMVSJ070GP/120-V2PC20 is a 120V 60Hz luminaire with a factory installed photocell. Note: Only the V2PC is available as a factory installed photocell. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1025 1026-1027.qxp 12/23/2013 3L 3:13 PM Page 1026 Photocells Cl. I, Div. 2, Groups A, B, C, D Maintains Cl. I, Div. 2 Suitability of Eaton's Crouse-Hinds Champ® Series Luminaires V2PC, D2S and EV2IH Series Dimensions: In Inches: V2PC EV2IH V2PCT D2S a b c d e EV2IH 5.00 4.25 2.60 4.54 5.25 3L Cat. # 1026 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1026-1027.qxp 12/23/2013 3:13 PM Page 1027 High Intensity Discharge (H.I.D.) Luminaires Hazardous 4L Description Page No. Application/Selection see page 1028 Class I and Class II Hazardous Area Lighting Integrally Ballasted Luminaires EVLS Hazard•Gard® Series EVLP Hazard•Gard® Series EVM Hazard•Gard® Series see pages 1029–1044 see page 1045 see page 1056 4L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1027 1028-1029.qxp 12/16/2013 4L 7:27 PM Page 1028 High Intensity Discharge (H.I.D.) Luminaires Hazardous Application and Selection Quick Selector Chart Applications: Luminaires contained in this section are for use: • In indoor or outdoor hazardous locations • As general area or spot lighting applications • Where longer lamp life provides desirable maintenance cost savings and return on investment through use of fewer luminaires, circuits and ancillary apparatus • Where relamping and maintenance difficulties require longer lamp life Considerations for Selection: Environmental: • Make sure luminaire meets NEC/CEC requirements for area in which it will be used Lighting levels required: • Can luminaire accept lamp of sufficient size to yield desired light level? Table 500.8(C) Identification Numbers. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Temp. Class (T Code) T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Quick Selector Chart 4L Electrical Characteristics Series EVLS Hazard•Gard® NEC Compliance Watts Volts Cl. I, Groups B (with suffix GB), C, D HPS: 50, 70, 100, 150 Multi-tap: 120, 208, 240, 277V/60Hz Cl. II Metal Halide: 70, 100, 175 Cl. III Pulse Start Metal Halide: 150, 175 Ballast 480V/60Hz Tri-tap: 120, 277, 347V/60Hz 220V/60Hz 220/240V /50Hz EVM Hazard•Gard® Cl. I, Groups B, C, D Cl. II, Groups E, F, G 50, 70, 100, 150, 175, 200, 250, 320, 400 (Mogul base) 50, 70, 100, 150, 175 (Mogul base) 120, 208, 240, 277, 347, 480, 600, MT 120, 208, 240, 277, 347, 480, 600, MT Champ® Series (see Section 3L) Cl. II, Groups E, F, G 70, 100, 150, 175 (Mogul base) 120, 208, 240, 277, 347, 480, 600, MT EVLP Hazard•Gard® Cl. I, Groups B, C, D 70, 100, 150, 175 (Medium base) 70, 100, 150, 175, 200, 250 (Mogul base) 120, 208, 240, 277, 347, 480, MT, TT Cl. II, Groups E, F, G Cl. III 70, 100 (Medium base) 70, 100, 150, 175 (Mogul base) 120, 208, 240, 277, 347, 480, MT, TT 1028 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business High power factor, constant wattage, reactor or autotransformer, integral High power factor, constant wattage integral High power factor, constant wattage, reactor or autotransformer, integral 1028-1029.qxp 12/16/2013 7:28 PM Page 1029 EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence A compact, affordable, explosionproof luminaire that has the best overall temperature performance ratings in its class! Eaton's Crouse-Hinds EVLS Hazard•Gard® is perfect as a general area lighting workhorse where space constraints exist. EVLS Hazard•Gard® is easy to install, 175 watts and less, has select options that are just right for your budget — AND it’s Class I, Division 1, Group B with GB option! Standard Materials: Applications: Ratings (Electrical Size): Eaton's Crouse-Hinds EVLS Hazard•Gard Lighting Fixures are used for general lighting and task lighting in: • Areas where flammable or explosive vapors or gases are present • Confined spaces or heavy process industry facilities • Petroleum refineries; chemical, petrochemical and pharmaceutical plants; oil terminals; gas plants • Waste treatment facilities • Drilling platforms and other coastal and offshore hazardous areas Features: Certification & Compliances: 4L • Bodies, mounting modules and cast guards – copper-free aluminum • Wire guard – stainless steel • Globe – heat- and impact-resistant glass • Gaskets – silicone and neoprene Standard Finishes: • Epoxy powder coat paint Sources/Wattages: • HID Medium Base (initial offering) HPS: 50, 70, 100, 150 watt Metal Halide: 70, 100, 175 watt Pulse Start Metal Halide: 150, 175 watt Voltages: • Multi-tap (120, 208, 240, 277V/60 Hz) • 480V/60 Hz • Tri-tap (120, 277, 347V/60 Hz) • 220V/60 Hz • 220/240V (or 230V)/50 Hz Transformer Types: • HX-HPF Standard • CWA Standard on 175W CWA Constant Wattage Autotransformer CWI Constant Wattage Insulation Transformer Available for HPS and MH, for most voltages and wattages (Additional voltages available on request.) Conduit Entries: • 3/4" and 1" NPT – pendant, ceiling and wall mount • 11/2" NPT – stanchion Two Start Acme Threads 4L • Compact and rugged - a Division 1 luminaire that fits in tight spaces • Smooth turning two start Acme threads for mounting modules and globe attachments save time and eliminate installation damage • Quick-connect design facilitates easy installation and saves money - install and wire the mounting module, and then screw in luminaire to make the electrical connection • Best overall T-rating in the industry for a medium-base HID lamp - use in elevated ambient and illuminate the most volatile areas of your facility - optimal safety in your high-risk areas • Factory-sealed - wired and sealed with no external sealing fittings required in Groups B, C, and D • An adapter module is available for direct connection to existing Hazard•Gard modules such as the EV22 ceiling mount UL and cUL Listed Wet locations (UL1598) Marine locations (UL1598A) Type 4X, IP66 Options: Description • Instant Restrike (HPS) • Ballast-Gard™ (HPS) • Group B Suitability Suffix IR BG GB Accessories: Description • Dome Reflector • Angle Reflector • Guard Suffix RD725 RA725 EV502 or P515 UL (844) and cUL Listed (CSA C22.2 No. 137) for: • Class I, Division 1, Groups B (with suffix GB), C, D • Class I, Zone 1, Group IIB + H2 (with suffix GB) • Class II, Class III & Simultaneous Presence • Wet locations (UL1598), Marine locations (UL1598A), Type 4X, IP66 www.crouse-hinds.com Quick Connect Design Adapter Module Available US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1029 1030-1031.qxp 12/16/2013 7:28 PM Page 1030 4L EVLS Hazard•Gard® Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence UL and cUL Listed Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Div. 1 Explosionproof Luminaire Mounting Modules: New Mounting Modules Existing For EVI, EVLP, EVM (must use EVSA adapter) Conduit Catalog Number Type Adapter Pendant ¾" 1" EVSA EVMP2 EVMP3 Ceiling & Wall Box ¾" 1" EV22 EV33 Wall Bracket Arm Use EV22 or EV33 box with EV87 Stanchion Bulkhead 1¼" 1¼" EVMJ4 EVJ2 Conduit ¾" 1" 25mm 32mm ¾" 1" 25mm 32mm ¾" 1" 25mm 32mm 1½" ¾" 25mm For EVLS Only Catalog Number EVSP2 EVSP3 EVSP25 EVSP32 EVSC2 EVSC3 EVSC25 EVSC32 EVSW2 EVSW3 EVSW25 EVSW32 EVSJ5 EVSB2 EVSB25 Family Tree: Existing Mounting Modules used on EVI, EVLP, EVM (must use EVSA adapter) EVMP2 EVMP3 EV22 EV33 EVMJ4 EVJ2 EV22 EV33 + EV87 EVSA ADAPTER EVSJ5 4L New Mounting Modules for EVLS EVSC2 EVSC3 EVSC25 EVSC32 EVSB2 EVSB25 EVSP2 EVSP3 EVSP25 EVSP32 EVSW2 EVSW3 EVSW25 EVSW32 EVLS (For example: EVLS9170) RA725 RD725 EV502 1030 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 P515 Copyright© 2013 Eaton’s Crouse-Hinds Business 1030-1031.qxp 12/16/2013 7:28 PM Page 1031 EVLS Hazard•Gard® UL and cUL Listed 4L Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire Ordering Reference Sheet: EVLS A 9 2 10 0 /MT -IR Hazard•Gard Low-Profile Luminaire Class I, Div. 1/Class I, Zone 1 Class II, Groups F & G A = Pendant Mounting Type BX = Wall CX = Ceiling BH = Bulkhead J = Stanchion M = Mounting Module Adapter 4 = High-Press. Sodium 9 = Metal Halide Lamp Type Conduit Entry (specify with mtg. modules) 2 = 3/4" NPT (Pendant, Ceiling, Bulkhead & Wall mounts only) 3 = 1" NPT (Pendant, Ceiling & Wall mounts only) 5 = 1-1/2" NPT (Stanchion only) 25 = 25 mm (Pendant, Ceiling, Bulkhead & Wall mounts only) 32 = 32 mm (Pendant, Ceiling & Wall mounts only) Note: Omit for mounting module adapter 05 = 50W HPS 07 = 70W HPS, MH 10 = 100W HPS, MH 15 = 150 HPS, MH Pulse Start 17 = 175W MH, MH Pulse Start Lamp Wattage by lamp type 0 = globe only, no guard 1 = stainless steel wire guard 2 = cast aluminum guard Guard (optional) Voltage and Frequency HPS 70 100 150 70 100 150 PS MT x x x x x x TT x x x x x x x x x x x x x x x x x x x DT 120 175 PS x x x x 208 220 220 50 175 4L 50 MH x 240 x x x x x x x x x x x x x x x x 240 50 x x x x x x x 277 x x x x x x x x 347 x x x 480 x x x BG = Ballast Guard (lamp type S only) CWI = SCE Ballast GB = Group B suitability IR = Instant Restrike (lamp type S only) S828 = Pulse Start (175W & 150W MH only) x x x x x x x Options Note: BG and IR options cannot be installed together. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1031 1032-1033.qxp 12/16/2013 7:28 PM Page 1032 4L EVLS Hazard•Gard® Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence UL and cUL Listed Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Div. 1 Explosionproof Luminaire Temperature Performance Data: Watts Ambient Temp °C High Pressure Sodium Class I, Div. 1 & Zone 1 Class II (Dust) and Class III Supply Wire Temp °C T5 T4A T4A T5 T4A T4A T4A T4 T4 T4A T4 T5 — — T5 — — T3C — — T3C — 90 90 105 90 90 105 90 90 105 90 90 T4A — — T4 — — — — — 90 90 105 90 90 105 90 90 90 40 55 65 40 55 65 40 55 65 40 55 50W 70W 100W 150W Metal Halide (including Pulse Start [PS] as indicated) 40 55 65 40 55 65 40 40 40 70W 100W 150 PS 175W 175 PS T5 T4A T4A T4A T4A T4 T3C T3C T3C Net Luminaire Weights (lbs.): Luminaire Series High Pressure Sodium EVLS4 Lamp Watts Weight with Globe & Wire Guard 18.5 21.5 22.5 24 70W 100W 150 PS 175W 175 PS Add for cast guard: 20 20.5 23 23 23 1 Add for mounting modules: Pendant Ceiling Stanchion Bulkhead Wall Adapter 2 3.5 3 2.5 5.5 2 Add for reflectors: Dome Angle 1.5 2 4L 50W 70W 100W 150W Metal Halide EVLS9 1032 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1032-1033.qxp 12/16/2013 7:28 PM Page 1033 EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence UL and cUL Listed 4L Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Ordering Information — High Pressure Sodium: Wattage Hub Size No Guard PENDANT Wire Guard Cast Guard No Guard BULKHEAD Wire Guard Cast Guard /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm EVLSA42050 EVLSA43050 EVLSA42051 EVLSA43051 EVLSA42052 EVLSA43052 EVLSBH42050 EVLSBH42051 EVLSBH42052 EVLSA425050 EVLSA432050 EVLSA42070 EVLSA43070 EVLSA425051 EVLSA432051 EVLSA42071 EVLSA43071 EVLSA425052 EVLSA432052 EVLSA42072 EVLSA43072 EVLSBH425050 EVLSBH425051 EVLSBH425052 EVLSBH42070 EVLSBH42071 EVLSBH42072 EVLSA425070 EVLSA432070 EVLSA42100 EVLSA43100 EVLSA425071 EVLSA432071 EVLSA42101 EVLSA43101 EVLSA425072 EVLSA432072 EVLSA42102 EVLSA43102 EVLSBH425070 EVLSBH425071 EVLSBH425072 EVLSBH42100 EVLSBH42101 EVLSBH42102 EVLSA425100 EVLSA432100 EVLSA42150 EVLSA43150 EVLSA425101 EVLSA432101 EVLSA42151 EVLSA43151 EVLSA425102 EVLSA432102 EVLSA42152 EVLSA43152 EVLSBH425100 EVLSBH425101 EVLSBH425102 EVLSBH42150 EVLSBH42151 EVLSBH42152 EVLSA425150 EVLSA432150 EVLSA425151 EVLSA432151 EVLSA425152 EVLSA432152 EVLSBH425150 EVLSBH425151 EVLSBH425152 3 50W 70W 100W 150W Complete Standard Voltage Ballasts catalog number as follows: NEC/UL CEC/CSA (cUL) Multi-tap 120V 480V Suffix /MT /120 /480 /TT /120 www.crouse-hinds.com /208CWI Export 240V CWI 480V CWI 600V CWI 220V 60 Hz 220V 50 Hz 240V 50 Hz /240CWI /480CWI /600CWI /220 /220 50 /240 50 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 4L Voltage Tri-Tap 120V 208V CWI 1033 1034-1035.qxp 12/16/2013 7:30 PM Page 1034 4L EVLS Hazard•Gard® Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence UL and cUL Listed Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Div. 1 Explosionproof Luminaire Ordering Information — High Pressure Sodium (Cont'd): Wattage /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm 3 50W 70W 100W 4L 150W WALL Wire Guard Cast Guard No Guard CEILING Wire Guard Cast Guard EVLSBX42050 EVLSBX43050 EVLSBX42051 EVLSBX43051 EVLSBX42052 EVLSBX43052 EVLSCX42050 EVLSCX43050 EVLSCX42051 EVLSCX43051 EVLSCX42052 EVLSCX43052 EVLSBX425050 EVLSBX432050 EVLSBX42070 EVLSBX43070 EVLSBX425051 EVLSBX432051 EVLSBX42071 EVLSBX43071 EVLSBX425052 EVLSBX432052 EVLSBX42072 EVLSBX43072 EVLSCX425050 EVLSCX432050 EVLSCX42070 EVLSCX43070 EVLSCX425051 EVLSCX432051 EVLSCX42071 EVLSCX43071 EVLSCX425052 EVLSCX432052 EVLSCX42072 EVLSCX43072 EVLSBX425070 EVLSBX432070 EVLSBX42100 EVLSBX43100 EVLSBX425071 EVLSBX432071 EVLSBX42101 EVLSBX43101 EVLSBX425072 EVLSBX432072 EVLSBX42102 EVLSBX43102 EVLSCX425070 EVLSCX432070 EVLSCX42100 EVLSCX43100 EVLSCX425071 EVLSCX432071 EVLSCX42101 EVLSCX43101 EVLSCX425072 EVLSCX432072 EVLSCX42102 EVLSCX43102 EVLSBX425100 EVLSBX432100 EVLSBX42150 EVLSBX43150 EVLSBX425101 EVLSBX432101 EVLSBX42151 EVLSBX43151 EVLSBX425102 EVLSBX432102 EVLSBX42152 EVLSBX43152 EVLSCX425100 EVLSCX432100 EVLSCX42150 EVLSCX43150 EVLSCX425101 EVLSCX432101 EVLSCX42151 EVLSCX43151 EVLSCX425102 EVLSCX432102 EVLSCX42152 EVLSCX43152 EVLSBX425150 EVLSBX432150 EVLSBX425151 EVLSBX432151 EVLSBX425152 EVLSBX432152 EVLSCX425150 EVLSCX432150 EVLSCX425151 EVLSCX432151 EVLSCX425152 EVLSCX432152 Hub Size No Guard Complete Standard Voltage Ballasts catalog number as follows: NEC/UL CEC/CSA (cUL) 208V Voltage Multi-tap 120V 480V Tri-Tap 120V CWI 240V CWI 480V CWI 600V CWI Suffix /240CWI /480CWI /600CWI /220 1034 /MT /120 www.crouse-hinds.com /480 /TT /120 US: 1-866-764-5454 /208CWI CAN: 1-800-265-0502 Export 220V 60 Hz Copyright© 2013 Eaton’s Crouse-Hinds Business 220V 50 Hz 240V 50 Hz /220 50 /240 50 1034-1035.qxp 12/16/2013 7:30 PM Page 1035 EVLS Hazard•Gard® Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire UL and cUL Listed 4L Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Ordering Information — High Pressure Sodium (Cont'd): ADAPTER STANCHION Wattage Hub Size 50W 70W 100W 150W Adapter 11/2" Adapter 11/2" Adapter 11/2" Adapter 11/2" No Guard Wire Guard Cast Guard EVLSJ45050 EVLSJ45051 EVLSJ45052 EVLSJ45070 EVLSJ45071 EVLSJ45072 EVLSJ45100 EVLSJ45101 EVLSJ45102 EVLSJ45150 EVLSJ45151 EVLSJ45152 No Guard Wire Guard Cast Guard Luminaire less mounting module and guard EVLSM4050 EVLSM4051 EVLSM4052 EVLS4050 EVLSM4070 EVLSM4071 EVLSM4072 EVLS4070 EVLSM4100 EVLSM4101 EVLSM4102 EVLS4100 EVLSM4150 EVLSM4151 EVLSM4152 EVLS4100 Complete STANDARD VOLTAGE BALLASTS catalog number as NEC/UL CEC/CSA (cUL) follows: Export Voltage Multi-tap 120V 480V Tri-Tap 120V 208V CWI Suffix /MT /TT /120 /480 /120 /208CWI 240V CWI 480V CWI 600V CWI 220V 60 Hz /240CWI /480CWI /600CWI /220 220V 50 Hz 240V 50 Hz /220 50 /240 50 4L Photometrics - EVLS High Pressure Sodium Fixture with Globe and Domed Reflector (less guard) EVLSA42150RD725 Lamp: 150W/B17 High Pressure Sodium (HPS) www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1035 1036-1037.qxp 12/16/2013 7:30 PM Page 1036 4L EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence Photometrics - EVLS High Pressure Sodium: Fixture with Globe and Guard EVLSA42151 Lamp: 150W/B17 High Pressure Sodium (HPS) Photometrics - EVLS High Pressure Sodium: 4L Fixture with Globe and Angled Reflector (less guard) EVLSA42150RA725 Lamp: 150W/B17 High Pressure Sodium (HPS) 1036 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business UL and cUL Listed Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 1036-1037.qxp 12/16/2013 7:30 PM Page 1037 EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence UL and cUL Listed 4L Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Ordering Information — Pulse Start Metal Halide: Wattage Hub Size 150W 175W 3/4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm No Guard PENDANT Wire Guard Cast Guard No Guard BULKHEAD Wire Guard Cast Guard EVLSA92150-S828 EVLSA93150-S828 EVLSA92151-S828 EVLSA93151-S828 EVLSA92152-S828 EVLSA93152-S828 EVLSBH92150-S828 EVLSBH92151-S828 EVLSBH92152-S828 EVLSA925150-S828 EVLSA932150-S828 EVLSA92170-S828 EVLSA93170-S828 EVLSA925151-S828 EVLSA932151-S828 EVLSA92171-S828 EVLSA93171-S828 EVLSA925152-S828 EVLSA932152-S828 EVLSA92172-S828 EVLSA93172-S828 EVLSBH925150-S828 EVLSBH925151-S828 EVLSBH925152-S828 EVLSBH92170-S828 EVLSBH92172-S828 EVLSA925170-S828 EVLSA925171-S828 EVLSA925172-S828 EVLSA932170-S828 EVLSA932171-S828 EVLSA932172-S828 EVLSBH925170-S828 EVLSBH925171-S828 EVLSBH92171-S828 EVLSBH925172-S828 Ordering Information — Pulse Start Metal Halide: 4L Wattage Hub Size 3 /4" 1" 11/2" 150W 25 mm 32 mm 3 /4" 1" 175W 11/2" 25 mm 32 mm No Guard WALL Wire Guard Cast Guard No Guard CEILING Wire Guard EVLSBX92150-S828 EVLSBX93150-S828 EVLSBX92151-S828 EVLSBX93151-S828 EVLSBX92152-S828 EVLSBX93152-S828 EVLSCX92150-S828 EVLSCX93150-S828 EVLSCX92151-S828 EVLSCX92152-S828 EVLSCX93151-S828 EVLSCX93152-S828 EVLSBX925150-S828 EVLSBX932150-S828 EVLSBX92170-S828 EVLSBX93170-S828 EVLSBX925151-S828 EVLSBX932151-S828 EVLSBX92171-S828 EVLSBX93171-S828 EVLSBX925152-S828 EVLSBX932152-S828 EVLSBX92172-S828 EVLSBX93172-S828 EVLSCX925150-S828 EVLSCX932150-S828 EVLSCX92170-S828 EVLSCX93170-S828 EVLSCX925151-S828 EVLSCX932151-S828 EVLSCX92171-S828 EVLSCX93171-S828 Cast Guard EVLSCX925152-S828 EVLSCX932152-S828 EVLSCX92172-S828 EVLSCX93172-S828 EVLSBX925170-S828 EVLSBX925171-S828 EVLSBX925172-S828 EVLSCX925170-S828 EVLSCX925171-S828 EVLSCX925172-S828 EVLSBX932170-S828 EVLSBX932171-S828 EVLSBX932172-S828 EVLSCX932170-S828 EVLSCX932171-S828 EVLSCX932172-S828 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1037 1038-1039.qxp 12/16/2013 7:30 PM Page 1038 4L EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence UL and cUL Listed Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Ordering Information — Pulse Start Metal Halide (Cont'd): STANCHION 4L Hub Wattage Size Adapter 3 /4" 1" 150W 11/2" 25 mm 32 mm Adapter 3 /4" 1" 175W 11/2" 25 mm 32 mm No Guard Wire Guard ADAPTER Cast Guard Wire Guard Cast Guard EVLSM9150-S828 EVLSM9151-S828 EVLSM9152-S828 EVLS9150-S828 EVLSJ95150-S828 EVLSJ95151-S828 EVLSJ95152-S828 EVLSM9170-S828 EVLSM9171-S828 EVLSM9172-S828 EVLS9100-S828 EVLS9170-S828 EVLSJ95170-S828 EVLSJ95171-S828 EVLSJ95172-S828 Complete catalog Standard Voltage Ballasts number as NEC/UL follows: Multi-tap 120V Voltage 480V Suffix /480 1038 No Guard Luminaire less mounting module and guard /MT www.crouse-hinds.com /120 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1038-1039.qxp 12/16/2013 7:30 PM Page 1039 EVLS Hazard•Gard® Cl. I, Div. 1, Groups B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire UL and cUL Listed 4L Wet locations (UL1598), Marine locations (UL1598A) Type 4X, IP66 Ordering Information — Metal Halide: PENDANT Wattage 70W 100W 175W† Hub Size 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm BULKHEAD No Guard EVLSA92070 EVLSA93070 Wire Guard EVLSA92071 EVLSA93071 Cast Guard EVLSA92072 EVLSA93072 No Guard EVLSBH92070 Wire Guard EVLSBH92071 Cast Guard EVLSBH92072 EVLSA925070 EVLSA932070 EVLSA92100 EVLSA93100 EVLSA925071 EVLSA932071 EVLSA92101 EVLSA93101 EVLSA925072 EVLSA932072 EVLSA92102 EVLSA93102 EVLSBH925070 EVLSBH925071 EVLSBH925072 EVLSBH92100 EVLSBH92101 EVLSBH92102 EVLSA925100 EVLSA932100 EVLSA92170 EVLSA93170 EVLSA925101 EVLSA932101 EVLSA92171 EVLSA93171 EVLSA925102 EVLSA932102 EVLSA92172 EVLSA93172 EVLSBH925100 EVLSBH925101 EVLSBH925102 EVLSBH92170 EVLSBH92171 EVLSBH92172 EVLSA925170 EVLSA932170 EVLSA925171 EVLSA932171 EVLSA925172 EVLSA932172 EVLSBH925170 EVLSBH925171 EVLSBH925172 †Export only. Complete Standard Voltage Ballasts catalog number as follows: NEC/UL Multi-tap 120V 480V Tri-Tap 120V Suffix /MT /120 /208CWI /480 /TT 240V CWI 480V CWI 600V CWI 220V 60 Hz 220V 50 Hz 230V* 50 Hz 240V 50 Hz /240CWI /480CWI /600CWI /220 /220 50 /230 50 /240 50 *Available for 175W only. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1039 4L Voltage 208V CWI /120 Export CEC/CSA (cUL) 1040-1041.qxp 12/16/2013 4L 7:31 PM Page 1040 EVLS Hazard•Gard® Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire UL and cUL Listed Wet locations (UL1598) Marine locations (UL1598A) Type 4X, IP66 Ordering Information — Metal Halide (Cont'd): WALL Wattage 70W 100W 175W† Hub Size 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm 3 /4" 1" 11/2" 25 mm 32 mm CEILING No Guard EVLSBX92070 EVLSBX93070 Wire Guard EVLSBX92071 EVLSBX93071 Cast Guard EVLSBX92072 EVLSBX93072 No Guard EVLSCX92070 EVLSCX93070 Wire Guard EVLSCX92071 EVLSCX93071 Cast Guard EVLSCX92072 EVLSCX93072 EVLSBX925070 EVLSBX932070 EVLSBX92100 EVLSBX93100 EVLSBX925071 EVLSBX932071 EVLSBX92101 EVLSBX93101 EVLSBX925072 EVLSBX932072 EVLSBX92102 EVLSBX93102 EVLSCX925070 EVLSCX932070 EVLSCX92100 EVLSCX93100 EVLSCX925071 EVLSCX932071 EVLSCX92101 EVLSCX93101 EVLSCX925072 EVLSCX932072 EVLSCX92102 EVLSCX93102 EVLSBX925100 EVLSBX932100 EVLSBX92170 EVLSBX93170 EVLSBX925101 EVLSBX932101 EVLSBX92171 EVLSBX93171 EVLSBX925102 EVLSBX932102 EVLSBX92172 EVLSBX93172 EVLSCX925100 EVLSCX932100 EVLSCX92170 EVLSCX93170 EVLSCX925101 EVLSCX932101 EVLSCX92171 EVLSCX93171 EVLSCX925102 EVLSCX932102 EVLSCX92172 EVLSCX93172 EVLSBX925170 EVLSBX932170 EVLSBX925171 EVLSBX932171 EVLSBX925172 EVLSBX932172 EVLSCX925170 EVLSCX932170 EVLSCX925171 EVLSCX932171 EVLSCX925172 EVLSCX932172 4L †Export only. Complete catalog number as follows: Standard Voltage Ballasts Voltage Multi-tap 120V 480V Tri-Tap 120V 208V CWI 240V CWI 480V CWI 600V CWI 220V 60 Hz 220V 50 Hz 230V* 50 Hz 240V 50 Hz Suffix /MT /480 /TT /120 /208CWI /240CWI /480CWI /600CWI /220 /220 50 /230 50 /240 50 NEC/UL /120 CEC/CSA (cUL) Export *Available for 175W only. 1040 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1040-1041.qxp 12/16/2013 7:31 PM Page 1041 Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire UL and cUL Listed Wet locations (UL1598) Marine locations (UL1598A) Type 4X, IP66 4L Ordering Information — Metal Halide (Cont'd): STANCHION Wattage 70W 100W 175W† Hub Size Adapter 11/2" Adapter 11/2" Adapter 3 /4" 11/2" No Guard Wire Guard ADAPTER Cast Guard EVLSJ95070 EVLSJ95071 EVLSJ95072 EVLSJ95100 EVLSJ95101 EVLSJ95102 EVLSJ95170 EVLSJ95171 No Guard Wire Guard EVLSM9070 EVLSM9071 Cast Guard EVLSM9072 Luminaire less mounting module and guard EVLS9070 EVLSM9100 EVLSM9101 EVLSM9102 EVLS9100 EVLSM9170 EVLSM9171 EVLSM9172 EVLS9100 EVLS9170 EVLSJ95172 †Export only. Complete catalog number as follows: Standard Voltage Ballasts NEC/UL CEC/CSA (cUL) Voltage Multi-tap 120V 480V Tri-Tap 120V 208V CWI Suffix /MT /120 /480 /TT /120 /208CWI Export 240V CWI 480V CWI 600V CWI 220V 60 Hz 220V 50 Hz 230V* 50 Hz 240V 50 Hz /240CWI /480CWI /600CWI /220 /220 50 /230 50 /240 50 *Available for 175W only. EVLS Metal Halide: www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 4L Fixture with Globe and Domed Reflector (less guard) EVLSA92170RD725 Lamp: 150W/ED17 Metal Halide (MH) 1041 1042-1043.qxp 4L 12/16/2013 7:31 PM Page 1042 EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence EVLS Metal Halide: Fixture with Globe and Guard EVLSA92171 Lamp: 175W/ED17 Metal Halide (MH) EVLS Metal Halide: 4L Fixture with Globe and Angled Reflector (less guard) EVLSA92170RA725 Lamp: 175W/ED17 Metal Halide (MH) 1042 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business UL and cUL Listed Wet locations (UL1598) Marine locations (UL1598A) Type 4X, IP66 1042-1043.qxp 12/16/2013 7:31 PM Page 1043 Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence EVLS Hazard•Gard® Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire UL and cUL Listed Wet locations (UL1598) Marine locations (UL1598A) Type 4X, IP66 4L Dimensions - Shown with new mounting modules: 10.97 3.16 15° 16.47 16.36 16.97 17.85 .61 8.47 .61 BULKHEAD MOUNT CEILING MOUNT 4.11 15.45 3.61 25° 17.43 8.28 17.18 16.82 4L .61 13.78 15.45 8.47 STANCHION MOUNT .61 PENDANT MOUNT 9.51 16.78 17.39 .61 8.47 WALL MOUNT www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1043 1044-1045.qxp 4L 12/16/2013 7:31 PM Page 1044 EVLS Hazard•Gard® Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 (with suffix GB) Cl. II, Cl. III & Simultaneous Presence Compact & Rugged, Class I, Zone 1, Div. 1 Explosionproof Luminaire UL and cUL Listed Wet locations (UL1598) Marine locations (UL1598A) Type 4X, IP66 Dimensions - Shown with existing mounting modules plus EVSA Adapter: 11 15/16" 15” 18 5/8" 19 3/16" 21 5/8" CEILING MOUNT EV22, EV33 BULKHEAD MOUNT EVJ2 18 7/16" 19 1/16" 19 11/16" 20 1/16" 19 9/16" 4L 25” 8 7/16" STANCHION MOUNT EVMJ4 9 1/2" PENDANT MOUNT EVMP2, EVMP3 3 5/16" 19" 19 5/8" WALL MOUNT BRACKET EV87 1044 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1044-1045.qxp 12/16/2013 7:31 PM Page 1045 EVLP Low Profile Hazard•Gard® (H.I.D.) Luminaires Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with suffix – GB), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III Medium and Mogul Base Marine & Wet Locations 3, 3R, 4, 4X; IP66 4L Applications: Standard Materials: Eaton's Crouse-Hinds Low Profile Hazard•Gard® luminaires are used in: • Areas where flammable or explosive vapors or gases are present • Hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired • Petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities • Waste treatment facilities • Drilling platforms and other coastal and offshore hazardous areas • Mounting modules, cover, ballast housing, globe holder – copper-free aluminum • Globe – heat and impact resistant glass • Exterior hardware – stainless steel • Reflectors (dome & angle) – Krydon® fiberglass-reinforced polyester • Copper-free aluminum – Corro-free™ powdered epoxy • Krydon – white • Stainless steel guard Features and Benefits: Ratings (Electrical/Size): Certifications and Compliances: • NEC and CEC: Class I, Division 1, Groups B (with suffix GB), C, D – All Wattages Class I, Zone 1, Groups IIB + H2 (with suffix GB), IIB, IIA – All Wattages Class II and Class III • UL Standards: 844, Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards C22.2 No. 137 Sources/Wattage: • Medium Base 70–150W HPS, 70–175W MH • Mogul Base 70–150W HPS, 70–250W MH Voltages: • Medium & Mogul H.I.D. 120V 60Hz Multi-tap (120, 208, 240, 277V 60Hz) Tri-tap (120, 277, 347V 60Hz) 480V 60Hz Other voltages – consult Eaton's Crouse-Hinds Conduit Entries: • 3/4", 1" NPT – pendant, wall bracket, ceiling • 11/4" NPT – stanchion Options: Description Suffix • Group B suitability ........................................................................................... GB • Ballast-Gard™ (HPS only) ................................................................................. BG • Instant restrike (Mogul Base only) ................................................................... IR 70–150W LX HPS Cannot use with BG Option • Fused (not suitable for marine applications).................................................... S658* • Quartz auxiliary lighting (Mogul Base only) ............................................................................................ QTZ Cannot use with IR option Uses 100W single ended double contract lamp Quartz lamp not included • Factory assembled with lamps ........................................................................ FA 4L • Small, compact size is perfect where low mounting restrictions are a concern. • Two start Acme threaded construction allows for easier assembly, installation and maintenance. • Lightweight copper-free aluminum housing with powdered epoxy finish for superior corrosion resistance. • All exterior hardware is corrosionresistant stainless steel. • Four mounting arrangements: pendant, ceiling, wall bracket and stanchion suit any lighting layout. • Wide range of light sources and wattages to meet specific lighting needs. • Marine and NEMA 4X construction suitable for outdoor, hose down, marine and corrosive environments. • Integral ballast for lowest installed cost. • High power factor (90%+) ballasts allows more fixtures per circuit. • Uses same mounting modules as the standard Hazard•Gard® for easy retrofitting when the EVLP is the preferred choice. • Internally fluted glass globe reduces glare and distributes light evenly – ideal for adverse enviroments typical of industrial facilities. • Krydon® construction dome and angle reflectors – won’t rust, corrode, dent, chip or peel • Now available in components – luminaire body, mounting module, guard, reflectors – allowing for easy stocking for Quick Ship requirements. Standard Finishes: *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Accessories: Description Cat. # Dome reflector Angle reflector RD739 RA739 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1045 1046-1047.qxp 4L 12/16/2013 7:31 PM Page 1046 EVLP Low Profile Hazard•Gard® Marine & Wet Locations 3, 3R, 4, 4X; IP66 Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with GB suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III Medium Base Ordering Information: Pendant Hub With Guard Watt Size (In.) Cat. # Wall Bracket Ceiling Stanchion Luminaire Body Less Mounting Module & Guard With Guard Cat. # With Guard Cat. # With Guard Cat. # Cat. # High Pressure Sodium /4 1 11/4 EVLPA142071 EVLPA143071 EVLPBX142071 EVLPBX143071 EVLPCX142071 EVLPCX143071 /4 100W 1 11/4 EVLPA142101 EVLPA143101 EVLPBX142101 EVLPBX143101 EVLPCX142101 EVLPCX143101 /4 150W 1 11/4 EVLPA142151 EVLPA143151 EVLPBX142151 EVLPBX143151 EVLPCX142151 EVLPCX143151 3 70W Pendant Mount 3 3 EVLP14070 EVLPJ144071 EVLP14100 EVLPJ144101 EVLP14151 EVLPJ144151 Pulse Start Metal Halide 3 /4 150W 1 11/4 EVLPA192151 S828 EVLPBX192151 S828 EVLPCX192151 S828 EVLPA193151 S828 EVLPBX193151 S828 EVLPCX193151 S828 /4 175W 1 11/4 EVLPA192171 S828 EVLPBX192171 S828 EVLPCX192171 S828 EVLPA193171 S828 EVLPBX193171 S828 EVLPCX193171 S828 3 †Wall Bracket Mount EVLP19150 S828 EVLPJ194151 S828 EVLP19175 S828 EVLPJ194171 S828 Metal Halide 3 /4 1 11/4 EVLPA192071 EVLPA193071 /4 100W 1 11/4 EVLPA192101 EVLPA193101 /4 175W 1 11/4 EVLPA192171 EVLPA193171 70W 4L 3 3 EVLPBX192071 EVLPBX193071 EVLPCX192071 EVLPCX193071 EVLP19070 EVLPJ194071 EVLPBX192101 EVLPBX193101 EVLPCX192101 EVLPCX193101 EVLP19100 EVLPJ194101 EVLPBX192171 EVLPBX193171 EVLPCX192171 EVLPCX193171 EVLP19175 EVLPJ194171 †Ceiling Mount Complete Catalog Number as follows: Standard Voltage Ballasts – 60Hz 1. NEC/UL Voltage Suffix Multi Tap /MT 120V /120 CEC/CSA (cUL) 480V /480 Tri Tap /TT 120V /120 Optional Voltage Ballasts – 50 or 60Hz *CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 600V CWI /600CWI EXPORT 220V 60Hz /220 220V 50Hz /220 50 230V 50Hz /230 50 2. 150W HPS Luminaires only Stanchion Mount ● ● 55V lamps – add suffix "LX" 100V lamps – add suffix "CE" †Ceiling and bracket mounts have 4 hubs: 3 are plugged. *CWI Isolated Ballasts are only available for high pressure sodium and 175W metal halide (non pulse start) luminaires. 1046 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 240V 50Hz /240 50 1046-1047.qxp 12/16/2013 7:31 PM Page 1047 EVLP Low Profile Hazard•Gard® Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with GB suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III Mogul Base 4L Marine & Wet Locations 3, 3R, 4, 4X; IP66 Ordering Information: Pendant With Guard Hub Watt Size(In.) Cat. # Wall Bracket With Guard Cat. # Ceiling With Guard Cat. # Stanchion With Guard Cat. # Luminaire Body Less Mounting Module & Guard Cat. # High Pressure Sodium 3 /4 1 11/4 EVLPA042071 EVLPA043071 EVLPBX042071 EVLPBX043071 EVLPCX042071 EVLPCX043071 /4 100W 1 11/4 EVLPA042101 EVLPA043101 EVLPBX042101 EVLPBX043101 EVLPCX042101 EVLPCX043101 /4 150W 1 11/4 EVLPA042151 EVLPA043151 EVLPBX042151 EVLPBX043151 EVLPCX042151 EVLPCX043151 70W 3 Pendant Mount 3 EVLP04070 EVLPJ044071 EVLP04100 EVLPJ044101 EVLP04150 EVLPJ044151 Pulse Start Metal Halide 3 /4 150W 1 11/4 EVLPA092151S828 EVLPBX092151S828 EVLPCX092151S828 EVLPA093151S828 EVLPBX093151S828 EVLPCX093151S828 /4 175W 1 11/4 EVLPA092171S828 EVLPBX092171S828 EVLPCX092171S828 EVLPA093171S828 EVLPBX093171S828 EVLPCX093171S828 /4 200W 1 11/4 EVLPA092201S828 EVLPBX092201S828 EVLPCX092201S828 EVLPA093201S828 EVLPBX093201S828 EVLPCX093201S828 /4 250W 1 11/4 EVLPA092251S828 EVLPBX092251S828 EVLPCX092251S828 EVLPA093251S828 EVLPBX093251S828 EVLPCX093251S828 3 3 †Wall Bracket Mount 3 EVLP09150S828 EVLPJ094151S828 EVLP09170S828 EVLPJ094171S828 EVLP09201S828 EVLPJ094201S828 EVLP09250S828 EVLPJ094251S828 Metal Halide 3 /4 1 11/4 EVLPA092071 EVLPA093071 /4 100W 1 11/4 EVLPA092101 EVLPA093101 EVLPBX092101 EVLPBX093101 EVLPCX092101 EVLPCX093101 /4 175W 1 11/4 EVLPA092171 EVLPA093171 EVLPBX092171 EVLPBX093171 EVLPCX092171 EVLPCX093171 /4 250W 1 11/4 EVLPA092251 EVLPA093251 70W 3 3 †Ceiling Mount EVLPCX092071 EVLPCX093071 EVLP09070 EVLPJ094071 EVLP09100 EVLPJ094101 4L 3 EVLPBX092071 EVLPBX093071 EVLP09170 EVLPJ094171 EVLPBX092251 EVLPBX093251 EVLPCX092251 EVLPCX093251 EVLP09250 EVLPJ094251 Complete Catalog Number as follows: Standard Voltage Ballasts – 60Hz 1. Voltage Multi Tap Suffix /MT NEC/UL 120V /120 CEC/CSA (cUL) 480V /480 Tri Tap /TT Optional Voltage Ballasts – 50 or 60Hz *CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix Stanchion Mount 208V CWI /208CWI 240V CWI /240CWI 600V CWI /600CWI 120V /120 EXPORT 220V 60Hz /220 220V 50Hz /220 50 230V 50Hz /230 50 240V 50Hz /240 50 2. 150W HPS Luminaires only • 55V lamps – add suffix "LX" • 100V lamps – add suffix "CE" Example: EVLPA043151/MT-LX †Ceiling and wall bracket mounts have 4 hubs: 3 are plugged. *CWI Isolated Ballasts are only available for high pressure sodium and 175W–250W metal halide (non pulse start) luminaires. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1047 1048-1049.qxp 12/16/2013 7:32 PM Page 1048 EVLP Low Profile Hazard•Gard® 4L Ordering by Components EVLP Luminaires are available in components. A • • • complete luminaire consists of: Mounting Module Luminaire Body Guard, Dome Reflector or Angle Reflector Mounting Modules: Type Pendant Conduit Cat. # 3 /4" 1" EVMP2 EVMP3 /4" 1" EV22 EV33 3 Ceiling & Wall Box Wall Bracket Arm Use EV22 or EV33 box with EV87 EV87 Stanchion 11/4" EVMJ4 Guards Medium Mogul EV511 EV512 Reflectors Dome Angle RD739 RA739 Pendant Ceiling Stanchion Ceiling Wall Bracket EVMP2 EVMP3 EV22 EV33 EVMJ4 EV22 EV33 EV87 & EV22 or EV33 4L Luminaire Body EVLP0 Series – H.I.D. Mogul Lamp EVLP1 Series – H.I.D. Medium Lamp 1048 www.crouse-hinds.com Guards Dome Reflector Angle Reflector EV511 EV512 RD739 RA739 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1048-1049.qxp 12/16/2013 7:32 PM Page 1049 4L Temperature Performance Data EVLP Low Profile Hazard•Gard® Medium Base Lamp Luminaires: Maximum Ambient Watts Class I, Group B (w/GB suffix) Groups C, D 40°C 55°C 65°C Class II, Groups E, F, G Class III Simultaneous Presence 40°C High Pressure Sodium 70W 100W 150W T5 T4A T4 T4A T4A T3C T4A T4 — T4A T4 — 90°C 90°C 90°C Metal Halide (including pulse start) 70W 100W 150W 175W T5 T3C T3C T3C T4A T3C T3B T3B T4A — — — T4 — — — 85°C 90°C 90°C 90°C Supply Wire °C Mogul Base Lamp Luminaires: Class II, Groups E, F, G Class III Simultaneous Presence Class I, Group B (w/GB suffix) Groups C, D Maximum Ambient Watts 40°C 55°C 65°C 40°C Supply Wire °C High Pressure Sodium 70W 100W 150W T6 T5 T4A T5 T4A T4 T5 — — T5 T4A T4 90°C 90°C 90°C Metal Halide (including pulse start) 70W 100W 150W 175W 200W 250W T6 T5 T4 T4 T3C T3C T5 T4A T3C T3C — — T5 T4A — — — — T5 T4A T3C T3C — — 85°C 90°C 90°C 90°C 90°C 90°C 4L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1049 1050-1051.qxp 12/16/2013 4L 7:32 PM Page 1050 EVLP Low Profile Hazard•Gard® Dimensions and Weights Dimensions In Inches: 4L Medium Base Mogul Base A B C D E F 13.92 15.69 12.73 14.69 16.50 18.25 16.71 18.46 20.59 22.34 19.36 21.30 Weights (lbs.): Luminaire w/guard Source High Pressure Sodium Watts Medium Mogul 70 100 150 34 36 36.5 36.5 38.5 39 70 100 150 175 200 250 33.5 34.5 36 36 — — 36 37 38.5 38.5 40.5 40.5 Metal Halide Medium Mogul Add Mounting Modules: Pendant Ceiling Bracket Stanchion 1 2 4.5 2.5 1 2 4.5 2.5 Add For Reflectors: RA739 RD739 Deduct for Wire Guard 1 1 0.5 1 1 0.5 1050 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1050-1051.qxp 12/16/2013 7:32 PM Page 1051 Photometric Data EVLP Low Profile Hazard•Gard® 4L Medium Base Medium Base Luminaire with Globe and Guard EVLPA143151 Lamp: 150W/B17 High Pressure Sodium (HPS) Medium Base Luminaire with Globe and Dome Reflector (Less Guard) EVLPA143150RD Lamp: 150W/B17 High Pressure Sodium (HPS) 4L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1051 1052-1053.qxp 12/16/2013 4L 7:32 PM Page 1052 EVLP Low Profile Hazard•Gard® Photometric Data Medium and Mogul Base Medium Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPA143150RA Lamp: 150W/B17 High Pressure Sodium (HPS) Mogul Base Luminaire with Globe and Guard 4L EVLPA043151 Lamp: 150W/E23-1/2 High Pressure Sodium (HPS) 1052 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1052-1053.qxp 12/16/2013 7:32 PM Page 1053 EVLP Low Profile Hazard•Gard® 4L Photometric Data Mogul Base Mogul Base Luminaire with Globe and Dome Reflector (Less Guard) EVLPA043150RD Lamp: 150W/E23-1/2 High Pressure Sodium (HPS) Mogul Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPA043150RA Lamp: 150W/E23-1/2 High Pressure Sodium (HPS) 4L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1053 1054-1055.qxp 12/16/2013 4L 7:32 PM Page 1054 Photometric Data EVLP Low Profile Hazard•Gard® Mogul Base Mogul Base Luminaire with Globe and Guard EVLPA093171 Lamp: 175W/ED28 Metal Halide (MH) Mogul Base Luminaire with Globe and Dome Reflector (Less Guard) 4L EVLPA093170RD Lamp: 175W/ED28 Metal Halide (MH) 1054 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1054-1055.qxp 12/16/2013 7:32 PM Page 1055 4L Photometric Data EVLP Low Profile Hazard•Gard® Mogul Base Mogul Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPA093170RA Lamp: 175W/ED28 Metal Halide (MH) 4L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1055 1056-1057.qxp 12/23/2013 4L 3:14 PM Page 1056 EVM Hazard•Gard® H.I.D. Luminaires Mogul Base Factory Sealed (Groups C, D) Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with suffix – GB), IIB IIA Cl. II, Div. 1, Groups E, F, G; Class III Applications: Options: Hazard•Gard® luminaires are used in: • Heavy process industries where flammable or explosive vapors, gases or combustible dusts are present • Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired • Petroleum refineries, chemical, petrochemical and other heavy process industry facilities • Paint spray facilities • Hazardous locations requiring elevated ambient capability • NEC and CEC: Class I, Division 1, Groups B (with suffix GB), C, D Class I, Zone 1, Groups IIB + H2 (with suffix GB), IIB, IIA 100W max – Paint Spray Suitability 175W max – Class II, Class III • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 Description Suffix • Fused – to protect ballast and capacitor against abnormal line conditions. (Not suitable for marine applications).................... S658§† • Instant restrike – enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of a cold lamp (50-150W LX HPS only). .............................. IR* • Quartz auxiliary lighting – quartz lamp comes to full brightness instantly upon restoration of power to provide emergency illumination during the normal restrike period of the H.I.D. lamp (for use with ED28 lamp). (Quartz lamp not included; use 100 W single-ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC.) ............................. QTZ‡ • Ballast-Gard™ – to eliminate the normally continuous high voltage pulsing in the event of a cycling lamp, inoperative lamp, or no lamp in the socket extending the life of the ballast. (For use with 50-400W HPS lamps.) ................................ BG* • Group B suitability – luminaires suitable for use in Class I, Group B hazardous (classified) locations...................................... GB • Hazard•Gard® supplied with trunnion arm for floodlighting applications. For use on pendant mount luminaires only. See Floodlight Section ....................... S812 Standard Materials: Size Ranges: • Mounting modules, cover, ballast housing, guard, globe ring – copper-free aluminum • Globe – heat and impact resistant glass • Exterior hardware – stainless steel • Lamp socket – porcelain with stainless steel screw shell • Reflectors – dome and angle: Krydon fiberglass-reinforced polyester material; high bay: Alzak aluminum • 3/ 4", 1" and 11/ 4" hubs (see ordering information – see pages 1057–1058) Features: 4L Paint Spray (100W max) Marine & Wet Locations 3, 3R, 4, 4X; IP66 • Luminaire is factory wired; power is fed through "wireless" connection block which serves as a mechanical seal between conduit and ballast compartments, eliminating the need for an external, field installed seal. The result is fast, easy installation. • Dome and 30° angle reflectors made of Krydon® material – won't rust, corrode, dent, chip or peel (order separately – see page 1059). • High bay reflectors of Alzak® aluminum for high wattage applications. • Internally fluted glass globes reduce glare and provide comfortable viewing light. • Wide range of light sources and wattages to meet specific lighting needs – 50 – 400W high pressure sodium (HPS); 70 – 400W metal halide (MH). • High power factor (90%+) ballasts reduce power costs – allow more luminaires per circuit. • Four mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket and stanchion. • Paint spray booth suitability on 50 to 100 watt luminaires provides efficient, economical H.I.D. lighting for areas where paint residue may accumulate on luminaires. • Elevated ambient capability permits reliable operation at high ambient temperature. Selected luminaires are suitable for ambient temperature up to 75°C. • Integral ballasts – separate ballasts are not required. Lowest installed cost. • Factory sealed, porcelain, mogul base socket. 1056 www.crouse-hinds.com US: 1-866-764-5454 Certifications and Compliances: Standard Finishes: • Copper-free aluminum – epoxy powder coat • Krydon – high reflectance white • Alzak – natural (anodized) CAN: 1-800-265-0502 Electrical Rating Ranges: • 120, 208, 240, 277, 347, 480, 600, multi-tap* • 50 to 400 watts *IR and BG options cannot be used together. †When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. ‡Can be used with BG option. §CSA Certified are not available with multi-tap ballast or S658 fuse option. Alzak is a registered trademark of ALCOA. Copyright© 2013 Eaton’s Crouse-Hinds Business 1056-1057.qxp 12/23/2013 3:14 PM Page 1057 50–400W EVM Hazard•Gard® H.I.D. Luminaires Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with suffix GB), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III Mogul Base Factory Sealed (Groups C, D) Pendant Luminaires Hub Without Size Guard Watts (In.) Cat. # High Pressure Sodium 3 /4 EVMA42050 1 EVMA43050 50 1 1 /4 Wall Bracket Luminaires Without Guard Cat. # Ceiling Luminaires With Guard Cat. # Without Guard Cat. # EVMA42051 EVMBX42050 EVMA43051 EVMBX43050 EVMBX42051 EVMBX43051 EVMCX42050 EVMCX42051 EVMCX43050 EVMCX43051 3 70 /4 1 11/4 EVMA42070 EVMA42071 EVMBX42070 EVMA43070 EVMA43071 EVMBX43070 EVMBX42071 EVMBX43071 EVMCX42070 EVMCX42071 EVMCX43070 EVMCX43071 3 100 /4 1 11/4 EVMA42100 EVMA42101 EVMBX42100 EVMA43100 EVMA43101 EVMBX43100 EVMBX42101 EVMBX43101 EVMCX42100 EVMCX42101 EVMCX43100 EVMCX43101 3 150 /4 1 11/4 EVMA42150 EVMA42151 EVMBX42150 EVMA43150 EVMA43151 EVMBX43150 EVMBX42151 EVMBX43151 EVMCX42150 EVMCX42151 EVMCX43150 EVMCX43151 3 200 /4 1 11/4 EVMA42200 EVMA42201 EVMBX42200 EVMA43200 EVMA43201 EVMBX43200 EVMBX42201 EVMBX43201 EVMCX42200 EVMCX42201 EVMCX43200 EVMCX43201 3 250 /4 1 11/4 EVMA42250 EVMA42251 EVMBX42250 EVMA43250 EVMA43251 EVMBX43250 EVMBX42251 EVMBX43251 EVMCX42250 EVMCX42251 EVMCX43250 EVMCX43251 400 /4 1 11/4 EVMA42400 EVMA42401 EVMBX42400 EVMA43400 EVMA43401 EVMBX43400 EVMBX42401 EVMBX43401 EVMCX42400 EVMCX42401 EVMCX43400 EVMCX43401 3 With Guard Cat. # 4L Paint Spray (100W max) Marine & Wet Locations 3, 3R, 4, 4X; IP66 With Guard Cat. # Stanchion Luminaires (25°) Without Guard Cat. # With Guard Cat. # EVMJ44050 EVMJ44051 EVMJ44070 EVMJ44071 EVMJ44100 EVMJ44101 EVMJ44150 EVMJ44151 EVMJ44200 EVMJ44201 EVMJ44250 EVMJ44251 Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows: Standard Voltage Ballasts – 60Hz NEC/UL 1. Voltage Suffix Multi Tap /MT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT Optional Voltage Ballasts – 50 or 60Hz CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI 600V CWI /600CWI EXPORT 220V 60Hz /220 2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix "CE" 3. Options - Add the Required Options Suffixes, see page 1056, in alpha-numeric order. www.crouse-hinds.com 120V /120 220V 50Hz /220 50 US: 1-866-764-5454 230V 50Hz /230 50 240V 50Hz /240 50 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1057 4L EVMJ44400 EVMJ44401 1058-1059.qxp 12/16/2013 4L 7:33 PM Page 1058 Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with suffix GB), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III 70–400W EVM Hazard•Gard® H.I.D Luminaires Factory Sealed (Groups C, D) Pendant Luminaires Watts Hub Size (In.) Without Guard Cat. # Pulse Start Metal Halide 3 EVMA92150 S828 /4 EVMA93150 S828 1 150 1 1 /4 4L EVMCX92151 S828 EVMCX93150 S828 EVMCX93151 S828 EVMCX93170 S828 EVMCX93171 S828 /4 1 11/4 EVMA92200 S828 EVMA92201 S828 EVMBX92200 S828 EVMBX92201 S828 EVMCX92200 S828 EVMCX92201 S828 EVMA93200 S828 EVMA93201 S828 EVMBX93200 S828 EVMBX93201 S828 EVMCX93200 S828 EVMCX93201 S828 /4 1 11/4 EVMA92250 S828 EVMA92251 S828 EVMBX92250 S828 EVMBX92251 S828 EVMCX92250 S828 EVMCX92251 S828 EVMA93250 S828 EVMA93251 S828 EVMBX93250 S828 EVMBX93251 S828 EVMCX93250 S828 EVMCX93251 S828 /4 1 11/4 EVMA92320 S828 EVMA92321 S828 EVMBX92320 S828 EVMBX92321 S828 EVMCX92320 S828 EVMCX92321 S828 EVMA93320 S828 EVMA93321 S828 EVMBX93320 S828 EVMBX93321 S828 EVMCX93320 S828 EVMCX93321 S828 /4 1 11/4 EVMA92400 S828 EVMA92401 S828 EVMBX92400 S828 EVMBX92401 S828 EVMCX92400 S828 EVMCX92401 S828 EVMA93400 S828 EVMA93401 S828 EVMBX93400 S828 EVMBX93401 S828 EVMCX93400 S828 EVMCX93401 S828 EVMA92070 EVMA92071 EVMBX92070 EVMBX92071 EVMCX92070 EVMCX92071 EVMA93070 EVMA93071 EVMBX93070 EVMBX93071 EVMCX93070 EVMCX93071 /4 1 11/4 EVMA92100 EVMA92101 EVMBX92100 EVMBX92101 EVMCX92100 EVMCX92101 EVMA93100 EVMA93101 EVMBX93100 EVMBX93101 EVMCX93100 EVMCX93101 /4 1 11/4 EVMA92170 EVMA92171 EVMBX92170 EVMBX92171 EVMCX92170 EVMCX92171 EVMA93170 EVMA93171 EVMBX93170 EVMBX93171 EVMBX93170 EVMCX93171 /4 1 11/4 EVMA92250 EVMA92251 EVMBX92250 EVMBX92251 EVMCX92250 EVMCX92251 EVMA93250 EVMA93251 EVMBX93250 EVMBX93251 EVMCX93250 EVMCX93251 /4 1 11/4 EVMA92400 EVMA92401 EVMBX92400 EVMBX92401 EVMCX92400 EVMCX92401 EVMA93400 EVMA93401 EVMBX93400 EVMBX93401 EVMCX93400 EVMCX93401 3 Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows: Standard Voltage Ballasts – 60Hz NEC/UL 1. Voltage Suffix Multi Tap /MT Dual-Tap /DT CEC/CSA (cUL) 120V /120 480V /480 Tri Tap /TT Dual-Tap /DT 120V /120 Optional Voltage Ballasts – 50 or 60Hz *CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 600V CWI /600CWI EXPORT 220V 60Hz 220V 50Hz 230V 50Hz /220 /220 50 /230 50 2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix "CE" 3. Options - Add the Required Options Suffixes, see page 1056, in alpha-numeric order. 240V 50Hz /240 50 *CWI Isolated Ballasts are only available for 175W–400W metal halide (non pulse start) luminaires. 1058 www.crouse-hinds.com Stanchion Luminaires (25°) Without Guard Cat. # EVMJ94150 S828 EVMBX93170 S828 EVMBX93171 S828 3 400 EVMCX92150 S828 EVMBX93150 S828 EVMBX93151 S828 EVMA93171 S828 3 250 EVMBX92150 S828 EVMBX92151 S828 EVMA93151 S828 EVMA93170 S828 3 175 EVMA92151 S828 EVMCX92171 S828 Metal Halide 3 /4 1 70 11/4 100 With Guard Cat. # EVMCX92170 S828 3 400 Without Guard Cat. # EVMBX92170 S828 EVMBX92171 S828 3 320 With Guard Cat. # EVMA92171 S828 3 250 Without Guard Cat. # EVMA92170 S828 3 200 With Guard Cat. # Ceiling Luminaires /4 1 11/4 3 175 Wall Bracket Luminaires Paint Spray (100W max.) Marine & Wet Locations 3, 3R, 4, 4X; IP66 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business With Guard Cat. # EVMJ94151 S828 EVMJ94170 S828 EVMJ94171 S828 EVMJ94200 S828 EVMJ94201 S828 EVMJ94250 S828 EVMJ94251 S828 EVMJ94320 S828 EVMJ94321 S828 EVMJ94400 S828 EVMJ94401 S828 EVMJ94070 EVMJ94071 EVMJ94100 EVMJ94101 EVMJ94170 EVMJ94171 EVMJ94250 EVMJ94251 EVMJ94400 EVMJ94401 1058-1059.qxp 12/16/2013 7:33 PM Page 1059 Accessories and Temperature Performance Data EVM Hazard•Gard® H.I.D. Luminaires 4L Reflectors Dome 30° Angle High Bay Type Cat. # Dome 30° Angle High Bay RD739 RA739 EV3912 Temperature Performance Data Maximum Ambient Class I Simultaneous Presence Paint Spray Booth Supply Wire 65°C 75°C 40°C 40°C 40°C °C T6 T5 T4A T4 T4 — — T5 T4A T4A — — — — T4 T4 T4 T3C — — — T4 T4 T4 T3C — — — T4A T4A T4A — — — — 90 90 90 90 90 90 90 T3 T3 — — — — — — T3C T3C T3C T3C — — — — T3C T3C T3C T3C — — — — T4A T4A — — — — — — 90 90 90 90 90 90 90 90 Metal Halide (Including Pulse Start) 70 T6 T6 T5 100 T5 T5 T4A 150 T4A T4 T4 175 T4A T4 T4 200 T4 T3C — 250 T4 T3C — 320 T3A — — 400 T3A — — www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 4L Watts 40°C 55°C High Pressure Sodium 50 T6 T6 70 T6 T6 100 T5 T5 150 T4A T4A 200 T4A T4A 250 T4 T3C 400 T3C — Class II (E, F, G) 1059 1060-1061.qxp 12/16/2013 7:33 PM Page 1060 EVM Hazard•Gard® H.I.D. Luminaires 4L Dimensions and Weights Dimensions: Luminaire Net Weights: H.I.D. Source Lamp Watts 50 70 100 High 150 (55V) Pressure 150 (100V) Sodium 200 250 400 70 100 175 250 400 Metal Halide Luminaire Only with Globe and Guard (lbs.) 40 40 44 45 44 46 46 55 39 39 42 43 51 Type Lbs. Type Add for Mounting Modules: Pendant Bracket 1 Ceiling Stanchion 2 Lbs. 41/4 21/4 4L Add for Reflectors: RD739 13/4 RA739 2 EV3912 21/2 Deduct: 11/2 lbs. for luminaire without guard. Guard EV503 EV5140 All – Reflectors 100, 175, 250W MV 50, 70, 100, All luminaires with QTZ option 150W HPS 70, 100, 175, 250W and 200, 250, 400W HPS MH 400W MV & MH Type EVMA EVMBX EVMCX EVMJ 1060 a 25 /16 277/8 24 2211/16 1 www.crouse-hinds.com b f 26 2813/16 2415/16 241/8 27 /16 301/8 261/4 251/4 US: 1-866-764-5454 g 5 CAN: 1-800-265-0502 28 /4 311/16 273/16 261/8 1 Dome – High Bay – 30° Angle – c d e 23 /8 2611/16 2213/16 253/8 7 Copyright© 2013 Eaton’s Crouse-Hinds Business 26 /16 293/4 253/8 2711/16 7 289/16 313/8 271/2 283/4 1060-1061.qxp 12/16/2013 7:33 PM Page 1061 EVM Hazard•Gard® H.I.D. Luminaires Photometric Data Lamp: 150W/E-23-1/2 high pressure sodium (HPS) Total bare lamp lumens: 16,000 Coefficient of Utilization Luminaire With Globe and Without Guard Note: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16,000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS – .25; 70W HPS – .40; 100W HPS – .59. Multipliers are for use with candela curve only. Luminaire spacing ratio is 0.80. Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .695 .644 .599 .579 .509 .450 .494 .417 .356 .410 .326 .262 .382 .305 .246 70 50 30 10 .659 .613 .570 .549 .484 .431 .469 .397 .341 .387 .311 .251 .363 .291 .236 50 50 30 10 .592 .555 .522 .491 .439 .393 .419 .360 .312 .344 .279 .229 .327 .265 .218 30 50 30 10 .531 .502 .474 .438 .396 .358 .373 .325 .284 .304 .250 .207 .292 .240 .200 10 50 30 10 .476 .451 .429 .390 .355 .325 .331 .291 .257 .267 .222 .184 .260 .217 .181 0 0 .399 .295 .230 .159 9 10 80 50 30 10 .342 .266 .212 .306 .234 .184 .278 .209 .160 .265 .198 .153 .233 .168 .127 70 50 30 10 .324 .254 .202 .292 .223 .176 .265 .201 .155 .253 .191 .149 .222 .163 .123 50 50 30 10 .292 .232 .187 .263 .203 .162 .240 .184 .143 .231 .177 .139 .203 .150 .114 30 50 30 10 .262 .211 .172 .236 .186 .148 .218 .167 .132 .210 .162 .129 .185 .138 .105 10 50 30 10 .234 .190 .156 .213 .169 .135 .195 .152 .121 .191 .149 .118 .167 .125 .096 0 0 .135 .116 .103 .103 .081 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1061 4L .159 Room Cavity Ratio 6 7 8 % Reflectance Eff. Ceil. Wall www.crouse-hinds.com 4L 1062-1063.qxp 12/16/2013 7:33 PM Page 1062 EVM Hazard•Gard® H.I.D. Luminaires 4L Photometric Data Lamp: 150W/E-23-1/2 high pressure sodium (HPS) Total bare lamp lumens: 16000 Lamp: 150W/E-23-1/2 high pressure sodium (HPS) Total bare lamp lumens: 16000 Luminaire With Globe, Hi-Bay Reflector and Without Guard Luminaire With Globe, Dome Reflector and Without Guard Note: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16,000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS – .25; 70W HPS – .40; 100W HPS – .59. Multipliers are for use with candela curve only. Note: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16,000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS – .25; 70W HPS – .40; 100W HPS – .59. Multipliers are for use with candela curve only. Luminaire spacing ratio is 1.00. Luminaire spacing ratio is 1.20. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% 4L % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .668 .651 .636 .618 .592 .569 .573 .542 .517 .531 .495 .468 .494 .455 .427 80 50 30 10 .716 .689 .666 .637 .596 .561 .568 .519 .480 .507 .452 .410 .455 .398 .355 70 50 30 10 .655 .639 .625 .608 .583 .564 .566 .536 .513 .525 .491 .464 .487 .452 .425 70 50 30 10 .700 .675 .653 .624 .585 .555 .559 .512 .476 .498 .447 .407 .446 .393 .353 50 50 30 10 .629 .616 .606 .587 .568 .550 .550 .525 .505 .511 .482 .459 .476 .446 .422 50 50 30 10 .668 .648 .631 .598 .567 .539 .538 .498 .466 .479 .435 .400 .432 .385 .349 30 50 30 10 .606 .597 .588 .569 .554 .539 .535 .514 .497 .498 .474 .454 .466 .438 .418 30 50 30 10 .640 .625 .610 .575 .549 .526 .518 .485 .457 .463 .425 .394 .417 .376 .344 10 50 30 10 .586 .578 .570 .553 .539 .528 .522 .504 .489 .487 .466 .449 .457 .433 .413 10 50 30 10 .615 .602 .590 .554 .532 .513 .500 .472 .448 .447 .415 .388 .404 .369 .339 0 0 .560 .517 .479 .439 .404 0 0 .575 .498 .434 .373 .326 % Reflectance Eff. Ceil. Wall % Reflectance Eff. Ceil. Wall Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .460 .420 .394 .427 .388 .361 .396 .358 .330 .369 .330 .303 .328 .288 .262 70 50 30 10 .455 .418 .391 .423 .385 .359 .392 .356 .329 .366 .328 .303 50 50 30 10 .444 .412 .388 .414 .380 .357 .385 .352 .328 30 50 30 10 .436 .407 .385 .406 .377 .354 10 50 30 10 .428 .402 .382 0 0 .373 1062 www.crouse-hinds.com Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .413 .355 .316 .373 .318 .280 .339 .285 .246 .312 .258 .221 .275 .222 .187 .325 .288 .262 70 50 30 10 .405 .352 .312 .368 .314 .277 .334 .283 .245 .308 .256 .221 .271 .222 .187 .360 .325 .301 .320 .285 .261 50 50 30 10 .392 .345 .309 .356 .307 .274 .324 .277 .243 .299 .252 .219 .264 .217 .185 .379 .348 .326 .354 .322 .300 .315 .282 .259 30 50 30 10 .380 .338 .306 .345 .303 .270 .316 .272 .241 .291 .247 .217 .257 .214 .183 .400 .373 .352 .373 .345 .324 .348 .319 .298 .311 .280 .258 10 50 30 10 .369 .331 .301 .337 .298 .267 .307 .267 .238 .283 .244 .215 .251 .210 .181 .343 .315 .290 .249 0 0 .289 .255 .226 .203 .170 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1062-1063.qxp 12/16/2013 7:33 PM Page 1063 5L Fluorescent Luminaires Hazardous and Non-Hazardous Description Page No. Application/Selection see page 1064 General Purpose Luminaires VF Vaporgard™ Series see page 1065 Non-metallic Luminaires NFL Series N2MVF see pages 1096–1098 see pages 1078–1082 Hazardous Area Luminaires CPMVF DMVF eLLB20 Series eLLK Series EVLPF EVF Series EVFDR Series EVFT Illuminator™ Series FVN Series FVS Series nLLK Series VMVF see see see see see see see see see see pages 1068–1069 pages 1071–1077 pages 1109–1111 pages 1099–1102 pages 1083–1088 see page 1112 pages 1116–1117 pages 1092–1095 pages 1106–1108 pages 1089–1091 pages 1103–1105 see page 1070 5L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1063 1064-1065.qxp 5L 12/16/2013 7:33 PM Page 1064 Fluorescent Lighting Luminaires Hazardous and Non-hazardous Application and Selection Quick Selector Chart Applications: Considerations for Selection: • For use in hazardous or non-hazardous areas (as shown in the Quick Selector Chart below) • Low operating cost • High light output per watt • Low brightness • Low glare • Uniform light • Instant illumination Having made the determination that a fluorescent luminaire is required, the remaining selection is the type of luminaire (i.e., number and kind of lamps) and placement of luminaire. To determine the number of luminaires: 1. Determine Cavity Ratios for room, ceiling and floor 2. Determine Coefficient of Utilization 3. Determine Light Loss 4. Determine Lamp Lumens required = Footcandles x Area Coefficient of Utilization x Light Loss Factor 5. Determine number of luminaires required = Total Lamp Lumens Required Lamp Lumens per Luminaire Table 500.8(C) Identification Numbers Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Temp. Class (T Code) T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Quick Selector Chart NEC – Hazardous Area Compliance Cl. I, Division 2, Groups A, B, C, D Lamp Watts 9 Volts 120 No. of Lamps 2 NFL Cl. I, Division 2, Groups A, B, C, D 32, 40 120–277V 50–60Hz 1, 2 FVN Cl. I, Division 2, Groups A, B, C, D; Cl. II, Groups F, G; Cl. III 32, 40, 60 120, 277, 220 / 240 50 or 60Hz 2, 3 EVF Cl. I, Groups C, D; Cl. II, Groups E, F, G 32, 40, 60, 110 120, 277, 347, 220 / 240 50 or 60Hz 1, 2, 3, 4 EVFDR Cl. I, Groups C, D; Cl. II, Groups E, F, G 32, 40, 60, 110 120, 277, 220 / 240 50 or 60Hz 2 EVFT Cl. I, Groups B, C, D; Cl. II, Groups E, F, G; Cl. III 39 120, 277, 220 / 240 50 or 60Hz 2, 4 FVS Cl. I, Division 2, Groups B, C, D; Cl. II, Groups E, F, G; Cl. III 40 120–277V, 50–60Hz or 347V, 60Hz 2 DMVF Cl. I, Division 2, Groups A, B, C, D; Cl. II, Groups E, F, G; Cl. III; Simultaneous Presence 26, 32, 42 120–277V, 50–60Hz or 347V, 60Hz 2, 3 N2MVF Cl. I, Division 2, Groups A, B, C, D; Class II, Groups F, G; Class III; Simultaneous Presence 26, 32 120–277V, 50–60Hz or 347V, 60Hz 2 EVLP Cl. I, Division 1, Groups (B), C, D; Cl. II, Groups E, F, G; Cl. III; Simultaneous Presence 26, 32 120–277V, 50–60Hz or 347V, 60Hz 2 CPMVF Cl. I, Division 2, Groups A, B, C, D 26, 32, 42 120–277V, 50–60Hz or 347V, 60Hz 2 eLLB 20 Cl. I, Division 2, Groups A, B, C, D; Cl. I, Zone 1, Group IIC; Cl. II, Division 2, Groups F, G 17, 32 120–240V, 50–60Hz 110–230VDC 2 eLLK Cl. I, Zone I & Division 2; Cl. II, Division 2 32 120–254V 2 nLLK Cl. I, Division 2, Groups A, B, C, D; Cl. I, Zone 2 AEx nA II; Cl. II, Division 2, Groups F, G 17, 32 120–277V, 60Hz 2 5L Series VF 1064 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1064-1065.qxp 12/16/2013 7:33 PM Page 1065 VF Series Vaporgard™ Fluorescent Luminaires 5L Cl. I, Div. 2, Groups A, B, C, D* Cl. I, Zone 2 IIC* Wet Locations 3, 3R Applications: Accessories: VF Series Vaporgard Fluorescent Lighting Luminaires are used: • Indoors or outdoors in industrial locations where enclosed and gasketed luminaires are required • Where the energy efficiency and long life of single twin tube compact fluorescent lamps are desired • Where luminaires may be subject to wet, damp, dirty locations • Where vibration and rough usage are a problem • To retrofit existing Vaporgard incandescent luminaires • In tunnels, building entrances, utility rooms, hallways and similar locations • With clear or colored globes to illuminate or mark critical locations or processes • See next page for complete listing Luminaire Net Weights: Fixture Type VFA VFHF VFHBF 43/4 5 71/4 5 51/4 71/2 • Copper-free aluminum – powder epoxy finish • Krydon material – high reflectance white Lbs. 1 Temperature Performance Data: Class I, Max. Supply Minimum Lamp Div. 2 Ambient Wire °C Operating 9W T3B 40°C 75°C -4°C (25°F) Electrical Ratings: • Input voltage – 120 VAC, 60 hertz • Wattages: two 9 watt lamps Dimensions In Inches: VFC Certifications and Compliances: VFH 5L • Compact size and light weight allow adaptation and easy installation in many industrial applications • Cast copper-free aluminum (less than 0.4 of 1% copper) construction and epoxy powder finish provide excellent resistance to corrosion • Variety of mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket, angle stanchion, through feed, box mount • VFH luminaire components can be installed on existing Vaporgard incandescent components and standard stamped metal boxes • Fixtures available for use with two compact 9 watt fluorescent lamps • Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity; will not chip, peel, dent, rust, or corrode (order separately – see pages 1066–1067) • Glass globes are internally fluted and stippled to reduce glare and provide even light distribution; exteriors are smooth to shed dust • All luminaires 120 VAC only! • Grounding wire for safety 2-Lamp Luminaire With Globe & Guard (lbs.) Type Lbs. Type Add for Reflectors: Dome 30° Angle 1 Deduct: 1/2 lb. for P21 Guard Standard Finishes: Features: 1-Lamp Luminaire With Globe & Guard (lbs.) VFHA VFHF VFHBF VFHT VFA • UL Standard: 1598, 844 • CSA Standard: C22.2 No. 137 Standard Materials: • Bodies and guards – copper-free aluminum (less than 0.4 of 1%) • Globes – clear or colored, glass or plastic • Reflectors – Krydon fiberglass-reinforced polyester material *All mountings except stanchion. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1065 1066-1067.qxp 12/16/2013 5L 7:34 PM Page 1066 Cl. I, Div. 2, Groups A, B, C, D† Cl. I, Zone 2 IIC† Wet Locations NEMA 3, 3R VF Series Vaporgard™ Fluorescent Luminaires Twin Tube Fluorescent with G24 Clear Glass Globe and P21 Guard (lamps not included) Pendant Mount Luminaire Watts Wall Mount (w/Box) Wall Mount (No Box) Pendant Hub Mount Size (In.) Cat. # Ceiling Mount Cat. # Wall Mount (w/Box) Cat. # /2 /4 1 11/4 VFHF122GP VFHF222GP VFHBF122GP VFHT122GP VFHBF222GP VFHT222GP VFA122GP VFA222GP VFA322GP 1 3 2 Lamps, 9W Each Ceiling Mount Wall Mount (No Box) Cat. # Angle Stanchion Angle Stanchion Mount* Cat. # Through Box Mount & Feed Mount Retrofit Through Feed Mount Cat. # Box Mount & Retrofit Cat. # VFC122GP VFC222GP VFH122GP VFHA422GP VF Series with Colored Glass Globes or Plastic Globes To obtain: • Substitute appropriate globe designation for "G" in above Cat. Nos. Accessories and Components Reflectors Globes Globe Color Clear Green Blue Red Amber Cat. # RD71 RA71 5L Type Dome (Cannot be used with wall mount luminaires) 30° Angle Guards Glass Cat. # G24 G25 G26 G27 G28 Plastic Cat. #* G63 G65 Guard For use with glass globes only Guard Cat. # P21 G67 Junction Boxes and Bracket Bodies VXF – 4 Hubs, 3 Plugs VXF – 4 Hubs, 3 Plugs Hub Size (In.) Cat. # /2 /4 VXF10 VXF20 1 3 VXT – 3 Hubs, 2 Plugs VXT – 3 Hubs, 2 Plugs Hub Size (In.) Cat. # /2 /4 VXT10 VXT20 1 3 VXFT – 5 Hubs, 4 Plugs VXFT – 5 Hubs, 4 Plugs Hub Size (In.) Cat. # /2 /4 VXFT10 VXFT20 1 3 VXA – Stanchion Mount (Non-hazardous Locations) VXA – Stanchion Mount (Non-hazardous Locations) Hub Size (In.) Cat. # 11/4 VXT-K1 Mounting Adapter Kit Description Cat. # Allows for the mounting of non-Eaton's Crouse-Hinds outlet boxes to the VXT20 wall VXT K1 mount bracket and VXH ceiling mount bracket *For non-hazardous locations. †All mountings except stanchion. 1066 www.crouse-hinds.com VXA4 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Page 1067 7:34 PM 12/16/2013 1066-1067.qxp 150W VDA15 VDA25 VDA35 200W VDA12 VDA22 VDA32 300W VDA13 VDA23 VDA33 PENDANT VDA/VFA FLUORESCENT VFA122 VFA222 VFA322 300W VDC23 FLUORESCENT VFC222 VXH12 VXH13 200W VFH122 FLUORESCENT 300W VXH15 150W G24 P21 PLATE 0305729 VXT-K1 GASKET 0305017 150W VXHBF25 5L 200W VXHBF22 RA71 300W VXHBF23 CLEAR HEAT RESISTING WALL & JUNCTION BOX VXHBF/VFHBF 300W GLOBE WITH GUARD G251 GLOBE & P22 GUARD ADAPTER KIT FOR MOUNTING VXT20 AND VXH15, VXH12, VXH13, VFH122 TO 4" OULET BOX (BY OTHERS) FLUORESCENT VFHF222 G34 RD71 CLEAR HEAT RESISTING 300W GLOBE WITHOUT GUARD 300W VXHF23 VXF20 VXFT20 (ORDER SEPARATELY) VXH15 VXH12 VXH13 VFH122 200W VXHF22 VXHF/VFHF BOX MOUNTING 150W VXHF25 VXH1/VFH1 BOX MOUNTING RA64 (NO GUARD AVAILABLE WHEN ORDERED WITH PLASTIC GLOBE) G24 CLEAR HEAT RESISTING G25 GREEN G26 BLUE G27 RED G28 AMBER G63 CLEAR PLASTIC POLYCARBONATE G65 GREEN PLASTIC POLYCARBONATE G67 RED PLASTIC POLYCARBONATE FLUORESCENT & 200W GLOBE & GUARD VDC/VFC P50 G54 150W GLOBE & GUARD THRU FEED 150W 200W VDC25 VDC22 G54 CLEAR HEAT RESISTING G55 GREEN G56 BLUE G57 RED G58 AMBER RD64 VXT20 VXH15 VXH12 VXH13 VFH122 VFHBF222 FLUORESCENT 0305016 GASKET VXF20 VXFT20 300W 200W 150W VXHT25 VXHT22 VXHT23 WALL MOUNT VXHT/VFHT FLUORESCENT VFHT222 150W 300W VXA4 VXH15 VXH12 VXH13 VFH122 200W VXHA45 VXHA42 VXHA43 VFHA422 FLUORESCENT VXHA4/VFHA4 ANGLE ADAPTER STANCHION MOUNT 1067 Copyright© 2013 Eaton’s Crouse-Hinds Business CAN: 1-800-265-0502 US: 1-866-764-5454 www.crouse-hinds.com 5L Family Tree VF Series Vaporgard™ Fluorescent Luminaires 1068-1069.qxp 5L 12/16/2013 7:34 PM Page 1068 CPMVF Champ-Pak™ Compact Fluorescent Luminaires Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP56 Applications: CPMVF Champ-Pak™ luminaires are used: • Indoor and outdoor wall mounting or vertical surface mounting where minimal luminaire depth is required in: – Manufacturing plants and heavy industrial facilities – Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical and platforms – Waste or sewage treatment plants – Offshore, dockside and harbor installations • For security and safety lighting in industrial facilities for lighting of loading docks, tunnels, and stairways • For marine, wet location, hose down, and corrosive environments Features and Benefits: • Unique compact shallow-profile design mounts virtually anywhere • Side hinged cover with two screw closing for easy installation and maintenance • Gray Corro-free™ epoxy powder coat two-piece housing provides superior corrosion resistance • Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance • Glass refractor provides uniform light distribution to eliminate glare • Silicon gaskets make luminaire suitable for NEMA 4X, marine environments • High power factor ballasts (+90%) are standard, which allow more luminaires per circuit 5L Certifications and Compliances: • NEC and CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 • IEC: Zone 2 Ex nR IIC • UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 Standard Materials: • Luminaire housing and door frame assembly – copper-free aluminum • External hardware – stainless steel • Lens – heat- and impact-resistant refractor style glass • Gaskets – silicon rubber • Reflector – aluminum light sheet • Wire guard – stainless steel Electrical Rating Ranges: • • • • Wattages: two 26, 32, or 42 watt lamps 120–277V, 50–60Hz 347V, 60Hz 12, 24, and 125VDC (Consult Eaton's Crouse-Hinds) Options: Description Restricted Breathing Construction........................................... Class I, Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) Certified for IEC Zone 2 ........................................................... S826TB Furnished with: Terminal Block Crimp Terminals Factory Assembled with Lamp................................................. FA Fused - protects ballast and capacitors against abnormal line conditions .......................................................................... (Not for use in Canada) (Not for marine use) S658 Accessories: Description Photocell for Field Installation • 120V, 50/60Hz ................................................................... • 208–240V, 50/60Hz ........................................................... • 277V, 50/60Hz ................................................................... Stainless Steel Wire Guard .................................................... Standard Finishes: • Aluminum – Corro-free™ epoxy powder coat • Stainless steel – natural Energy Savings: • Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output 1068 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Suffix S826 Copyright© 2013 Eaton’s Crouse-Hinds Business Cat. # V2PC20 V2PC22 V2PC27 P55 1068-1069.qxp 12/16/2013 7:34 PM Page 1069 CPMVF Champ-Pak™ Compact Fluorescent Luminaires Ordering Information Temperature Performance Data Dimensions & Weights 5L Ordering Information: Hub Size (In.) Luminaire Watts Cat. # /4 NPT /4 NPT 52 64 CPMVF2W052 CPMVF2W064 /4 NPT 84 CPMVF2W084 3 3 3 STANDARD VOLTAGE BALLASTS OPTIONAL BALLASTS NEC/UL & CEC/CSA (cUL) CEC/CSA (cUL) 120–277V 50–60Hz 347V 60Hz 125V DC 12V DC 24V DC /UNV /347 /125VDC /012VDC /024VDC Voltage Suffix (Consult Eaton's Crouse-Hinds) CPMVF Temperature Performance Data – Consult Eaton's Crouse-Hinds Dimensions In Inches: 5L Net Weight: Description CPMVF Less Guard P55 Guard Lbs. 17 lbs. 0.5 lbs. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1069 1070-1071.qxp 5L 12/16/2013 7:42 PM Page 1070 VMVF Series Fluorescent Luminaires Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II, Ex nR IIC IEC Zone 2, Ex nR IIC UL/CSA IEC 60079-15 Champ® Luminaires Applications: VMVF Series Champ Luminaires are used: • In refineries, chemical, petrochemical, and pharmaceutical plants, wastewater treatment facilities • In shipboard, drilling rigs, drilling platforms • In flour and feed mills, grain elevators, sugar and cocoa plants • In area/structure lighting, security lighting, parking areas Features and Benefits: Increased Productivity • Instant-on luminaire eliminates flicker-free starting and increases safety and productivity Consistent Design • Luminaire components are of the same materials as standard VMV and DMV • Popular components are available from stock; offers visual consistency throughout installation High Lumen Output • Compact fluorescent light fixture provides higher lumen output with increased color rendering index (CRI) Reliable Performance in Any Environment • Energy-efficient universal ballast suitable for 120-277V 50/60Hz minimum starting temperature of -18°C provides long lamp life and lamp end-of-life protection • UL marine rated, NEMA 4X/IP66 luminaire prevents water ingress and is suitable for the most adverse outdoor environments Certifications and Compliances: • NEC/CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx nR II, Ex nR IIC • IEC: IEC Zone 2, Ex nR IIC • UL Standards: UL844 Hazardous (Classified) Locations UL1598 Luminaires, UL1598A Marine Locations • CSA Standards: C22.2 No. 137 • IEC Standards: IEC 60079-15 Ordering Information Example: 5L VMV F 2A 042 1. Series VMV DMV 2. Lamp/Function F (Fluorescent) FB (Fluorescent with Battery Back-up) (DMV only) 3. Mounting Style Blank No Cover J 1 1/2” Stanchion 25º P 1 1/2” Stanchion Straight 2A 3/4” Pendant 3A 1” Pendant 2C 3/4” Ceiling 3C 1” Ceiling 2HA 3/4” Offset Pendant (low wattage only) 2TW 3/4” Wall Mount 3TW 1” Wall Mount 25Q 3/4” Quad Mount 4. Wattage 042 42W F (VMVF) 084 84W F (DMVF/DMVFB) 5. Globe and Guard GP G24 Globe and P21 Guard (VMVF) GP G303 Globe and P33 Guard (DMVF) 6. Voltage /UNV 120-277V 50/60Hz Fluorescent /347 (For Canada) 7. Suffixes S714 Furnished with Lamps S806 Cover Furnished with Stainless Steel Insert S826 Restricted Breathing (Cl. I, Div. 2 & Zone 2 Suitability, Cooler T-Numbers) S826TB Restricted Breathing Supplied with Terminal Block Connections (Certified for IEC Zone 2) S858 Red Paint for Exterior S890 Quick Clip FA Factory Assembled with Lamps Installed 1070 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 GP Copyright© 2013 Eaton’s Crouse-Hinds Business /UNV S714 1070-1071.qxp 12/16/2013 7:42 PM Page 1071 DMVF Series Compact Fluorescent Champ® Luminaires Applications: DMVF Series Champ Luminaires are used: • In areas made hazardous by abnormal conditions resulting in the presence of flammable vapors or gases Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) 5L Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 Certifications and Compliances: • NEC and CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) • In areas made hazardous by the presence of combustible dusts Class I, Zone 2 • Where combustible dusts and flammable vapors are present simultaneously • IEC: • In marine applications where water spray and corrosive atmospheres are considerations • UL Standards: • On installations where vibration and rough usage are problematic Zone 2 Ex nR IIC 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • Where a cool, efficient light source is required • CSA Standards: • In areas that require lamps to reach full illumination immediately • IEC Standards: • In refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants, wastewater treatment plants, sewage treatment plants, oil terminals, food processing facilities, breweries, and any other manufacturing or processing facility where safe, reliable, hazardous area fluorescent or auxiliary lighting is needed C22.2 No. 137 Accessories: Reflectors (to be used with globe) Type Cat. # 60079-15 Standard Materials: Dome 30° Angle • Ballast housings and mountings – copper-free aluminum (less than 0.4 of 1%) To be ordered separately. • Exterior hardware and guards – stainless steel • Reflectors – Krydon® fiberglassreinforced polyester Standard Features: • Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion • Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation • Epoxy powder finish and stainless steel external hardware for resistance to corrosion • Long-life gaskets which provide seals between mounting module, housing, and optical assembly • Grounding wire for safety • Cool operating design • Optional stainless steel open bottom guard permits direct access to the globe for easy relamping • Optional battery pack ballast for auxiliary lighting Standard Finishes: • Aluminum – gray epoxy powder coat • Krydon material – high reflectance white • Stainless steel – natural Energy Savings • Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output Electrical Rating Ranges: • Wattage: Two 26, 32, or 42 watt lamps • 120–277V, 50–60Hz • 347V, 60Hz • 12, 24, and 125VDC 5L • Mounting modules equipped with integral hub set screws for vibration resistance (ceiling, pendant, and quad mounts) • Globe – heat- and impact-resistant internally fluted glass RD739 RA739 Options: Description Suffix Restricted Breathing Construction ................................................................................. S826 Class I, Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) Certified for IEC Zone 2 (Suffix S826TB) ........................................................................S826TB Furnished with Terminal Block Crimp Terminals Factory assembled with lamps installed for additional labor savings ........................... FA Fused – to protect ballast against abnormal line conditions (not available on CSA certified fixtures) (not suitable for marine applications) ................................................. S658 Lamps supplied with fixture........................................................................................... S714 Top hat with stainless steel threaded insert to attach ballast housing.......................... S806 TEFLON® coating on globe for increased shatter protection......................................... S808 Quick-Clip ....................................................................................................................... S890 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1071 1072-1073.qxp 5L 12/16/2013 7:34 PM Page 1072 DMVF Series Compact Fluorescent Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Champ® Luminaires Mounting Style Pendant Mount Hub Luminaire Size (In.) Watts 3 /4 1 /4 1 3 /4 1 52 3 64 /4 /4 3 /4 52 64 84 DMVF2HA052GP DMVF2HA064GP DMVF2HA084GP /4 1 3 /4 1 3 /4 1 52 DMVF2C052GP DMVF3C052GP DMVF2C064GP DMVF3C064GP DMVF2C084GP DMVF3C084GP /4 1 3 /4 1 3 /4 1 52 Flexible Pendant Mount 3 Ceiling Mount Thru-Feed 3 Wall Mount Thru-Feed DMVF Series Fluorescent with G303 Globe and P33 Guard Cat. # DMVF2A052GP DMVF3A052GP DMVF2A064GP DMVF3A064GP DMVF2A084GP DMVF3A084GP 84 3 64 84 3 64 84 DMVF2TW052GP DMVF3TW052GP DMVF2TW064GP DMVF3TW064GP DMVF2TW084GP DMVF3TW084GP 3 3 /4 /4 3 /4 52 64 84 DMVF25Q052GP DMVF25Q064GP DMVF25Q084GP Stanchion Mount 25° Angle 11/2 11/2 11/2 52 64 84 DMVFJ052GP DMVFJ064GP DMVFJ084GP Stanchion Mount Straight 11/2 11/2 11/2 52 64 84 DMVFP052GP DMVFP064GP DMVFP084GP 5L Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle 1. Catalog numbers are basic numbers. Voltages must be specified. STANDARD VOLTAGE BALLASTS NEC/UL & CEC/CSA (cUL) CEC/CSA (cUL) Voltage Suffix 1072 120–277V 50–60Hz /UNV www.crouse-hinds.com US: 1-866-764-5454 347V 60Hz /347 CAN: 1-800-265-0502 OPTIONAL BALLASTS 125V DC /125VDC 12V DC /012VDC 24V DC /024VDC Copyright© 2013 Eaton’s Crouse-Hinds Business Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 1072-1073.qxp 12/16/2013 7:34 PM Page 1073 5L DMVF Series – Ordering by Components DMVF luminaires are available in components. A complete I. II. III. luminaire consists of: Champ Cover (Mounting Module) DMVF Ballast Housing Globe, Globe Guard, Globe Reflectors I. Champ Cover (Mounting Module): Type Pendant Mount Conduit Cat. # /4" 1 APM2 APM3 Flexible Pendant 3 /4" HPM2 Ceiling 3 /4" 1 CM2 CM3 Wall 3 /4" 1 TWM2 TWM3 Stanchion - 25 Degree Angle 11/2" JM5 Stanchion - Straight 11/2" PM5 Quad-Mount 3 /4" QM25 3 II. Ballast Housings: Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes. Lamp Type Compact Fluorescent Lamp Watts Cat. # 2 (26W) 2 (32W) 2 (42W) DMVF052/UNV DMVF064/UNV DMVF084/UNV III. Globe, Guards and Reflectors: Cat. # Globe Teflon Coated Globe Guard Globe Reflector-Dome Globe Reflector-Angle G303 G303S808 P33 RD739 RA739 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 5L Type Copyright© 2013 Eaton’s Crouse-Hinds Business 1073 1074-1075.qxp 5L 12/16/2013 7:34 PM Page 1074 DMVF Series Compact Fluorescent Family Tree 5L Champ® Luminaires *These plastic reflectors are for non-hazardous areas only (50-100W max). 1074 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1074-1075.qxp 12/16/2013 7:34 PM Page 1075 DMVF Series Compact Fluorescent 5L Temperature Performance Data Weights Champ® Luminaires Temperature Performance Data: Lamp Watts Minimum Operating Temperature Maximum Ambient Temp. Fluorescent: DMVF Class I Non-restricted Restricted Breathing Breathing Div. 2 Class II Simultaneous Presence Non-restricted Restricted Breathing Breathing Zone 2 or Div. 2 Division 1 Cl. I, Div. 2/Cl. II Cl. I, Zone 2 or Div. 2/Cl. II Supply Wire °C 52 Watt –20°C (4°F) 40°C (104°F) T3 T6 T6 T3/T6 T6 60 64 Watt –20°C (4°F) 40°C (104°F) T3 T6 T6 T3/T6 T6 60 84 Watt –20°C (4°F) 40°C (104°F) T3 T6 T6 T3/T6 T6 60 Net Luminaire Weights: Luminaire Series Luminaire with Globe, Guard (lbs.) Lamp Watts 181/4 Lbs. DMVF 52, 64, 84 Type Add for mounting modules: Pendant Flexible Pendant Ceiling Wall Quad-Mount Angle Stanchion Straight Stanchion 11/4 11/2 23/4 41/2 31/2 31/2 41/2 Add for reflectors: Dome 11/4 30° Angle Deduct: 1 lb. for luminaire with P33 Guard 13/4 5L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1075 1076-1077.qxp 12/16/2013 5L 6:50 PM Page 1076 DMVF Series Compact Fluorescent Photometric Data Champ® Luminaires Note: For 52 watt DMVF applications, use a .75 multiplier. For complete 84W IES files, please log onto www.crouse-hinds.com and go to Resources > Specification and Design Support > Photometric Files. DMVF Photometric Data Isofootcandle Chart: Luminaire with globe and dome reflector DMVF064GRD Dome Reflector DMVF064GRD Dome Reflector Coefficient of Utilization Effective Floor Cavity Reflectance 20% Eff. Ceil. 5L Footcandle Values for Isofootcandle Lines Mtg. Hgt. A B C D E 8' 10' 12' 16' 4.00 2.56 1.78 1.00 2.00 1.28 0.89 0.50 1.00 0.64 0.44 0.25 0.50 0.32 0.22 0.13 0.25 0.16 0.11 0.06 Room Cavity Ratio Wall 1 2 3 4 5 6 7 8 9 10 80* 50* 30* 10* .741 .694 .652 .617 .548 .491 .524 .445 .382 .452 .370 .308 .396 .314 .254 .351 .271 .214 .314 .237 .183 .283 .210 .159 .258 .188 .140 .236 .169 .125 70* 50* 30* 10* .722 .679 .640 .601 .537 .483 .510 .437 .378 .440 .364 .305 .386 .309 .252 .342 .267 .212 .307 .234 .182 .277 .207 .158 .252 .185 .139 .231 .167 .124 50* 50* 30* 10* .686 .650 .617 .570 .516 .470 .484 .421 .369 .418 .351 .299 .367 .299 .247 .326 .259 .209 .293 .227 .180 .265 .202 .155 .242 .181 .138 .223 .163 .123 30* 50* 30* 10* .653 .623 .596 .542 .497 .457 .460 .406 .361 .398 .340 .293 .350 .290 .243 .311 .251 .206 .280 .221 .177 .254 .197 .154 .233 .176 .136 .214 .160 .121 .50* 30* 10* 0* .622 .598 .576 .557 .516 .478 .444 .424 .437 .392 .352 .332 .379 .329 .287 .267 .333 .271 .239 .220 .297 .244 .203 .184 .268 .215 .175 .157 .244 .192 .152 .136 .224 .172 .135 .119 .206 .156 .120 .105 10* 0* *Percent Reflectance. 1076 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1076-1077.qxp 12/16/2013 6:50 PM Page 1077 DMVF Series Compact Fluorescent Dimensions 5L Champ® Luminaires Dimensions In Inches: Pendant Mount Quad-Mount 25° Angle Stanchion Mount Wall Mount 5L Ceiling Mount Ceiling Mount – Top View Straight Stanchion Mount Luminaire with Globe, Guard, Reflectors www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1077 1078-1079.qxp 5L 12/16/2013 6:50 PM Page 1078 N2MVF Series Compact Fluorescent Marine & Wet Locations Cl. I, Div. 2, Groups A, B, C, D 3, 3R, 4, 4X; IP56 Cl. II, Groups F, G Cl. III & Simultaneous Presence Champ® Non-metallic Luminaires Applications: N2MVF Series Champ Luminaires are used: • In areas in which ignitable concentrations of flammable gases or vapors will be present due to abnormal, unusual or accidental conditions • In installations where moisture, dirt, vibration, corrosion, or rough usage are concerns • Wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements are found • Ideal for marine use; resists the harmful effects of salt water • Withstands the harshest of corrosive environments • To provide low wattage spot and floodlighting • For general area lighting • In manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment facilities, offshore, dockside, and harbor installations as well as other heavy industrial applications 5L Features and Benefits: • Housings and mounting modules made of polyphenylene sulfide (PPS) for strength and maximum resistance to corrosion • Pendant mounting module equipped with integral hub set screws for vibration resistance • Hubs are provided with an integral bushing to help prevent damage to field wiring during installation and ground connection for positive bonding • Guard, hub inserts, stanchion elbow, and hardware made of stainless steel for maximum resistance to corrosion • Grounding wire for safety • Stainless steel open bottom guard permits direct access to the globe for easy relamping • Hinged assembly allows the luminaire to hang free during installation to permit the use of both hands when wiring • One external captive screw for ease of installation • Handle – hinge assembly doubles as a handle for ease of installation, especially when carrying up a ladder Certifications and Compliances: • NEC and CEC: Class I, Division 2, Groups A, B C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and II) • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 Standard Materials: • Housing, mounting modules – polyphenylene sulfide (PPS) • Guard, hub inserts, stanchion elbow, hardware – stainless steel • Globe – heat- and impact-resistant, internally fluted glass • Gaskets – silicone rubber Electrical Ratings: • Wattages: Two 26 or 32 watt lamps • 120-277V, 50-60Hz • 347V, 60Hz • 12, 24, and 125 VDC Average Luminaire Weight Description Body, mounting module, globe, guard, and reflector Fluorescent Energy Savings • Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output Mounting Style Hub Size in. Lamp Watts 3 /4 1 /4 1 52 3 64 /4 1 3 /4 1 52 Ceiling Mount Thru-Feed Stanchion Mount 25° Angle 11/2 11/2 52 64 Pendant Mount 3 Voltage Suffix 120–277V 50–60Hz /UNV Minimum Operating Temperature 52 & 64 Watt –18°C (0°F) US: 1-866-764-5454 With G303 Globe and P33 Guard Cat. # N2MVF2A052GP N2MVF3A052GP N2MVF2A064GP N2MVF3A064GP N2MVF2C052GP N2MVF3C052GP N2MVF2C064GP N2MVF3C064GP 64 Maximum Ambient Temp. Fluorescent: N2MVF www.crouse-hinds.com 30 N2MVFJ052GP N2MVFJ064GP Optional Ballasts CEC/CSA (cUL) 347V 60Hz /347 125V DC /125VDC 12V DC /012VDC 24V DC /024VDC Temperature Performance Data: Lamp Watts 1078 Lbs. Ordering Information: Standard Voltage Ballasts NEC/UL & CEC/CSA (cUL) Additional Features: Options: Description Suffix Wall-Mount Arm For converting a ceiling-mount luminaire to a wall mount .......... N2MV-WM1 Factory Assembled For a factory assembled luminaire with lamps installed ........... FA Fusing To protect ballast against abnormal line conditions (not suitable for marine applications) ...... S658 Furnished with Lamps ....................... S714 Teflon Coated Globe Provides additional protection against shattered glass fragments when subject to thermal shock, etc. ........................... S808 CAN: 1-800-265-0502 40°C (104°F) Class I Non-restricted Breathing Class II Division 2 Division 1 T2D T4 Copyright© 2013 Eaton’s Crouse-Hinds Business Supply Wire °C 85 1078-1079.qxp 12/16/2013 6:50 PM Page 1079 5L N2MVF Series Ordering by Components N2MVF Luminaires are available in components. A complete luminaire consists of: I. N2MV Cover (Mounting Module) II. N2MV Ballast Housing III. Globe, Refractors, Guards, Reflectors I. N2MV Cover (Mounting Module): Type Pendant Conduit Cat. # 3 /4" 1" N2APM2 N2APM3 Ceiling 3 /4" 1" N2CM2 N2CM3 Wall (Use wall bracket accessory with Ceiling Cover) Stanchion – 25 Degree Angle 3 /4" 1" N2MV WM1 and N2CM2 N2MV WM1 and N2CM3 11/2" N2JM5 II. Ballast Housings: Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes. Lamp Lamp Type Watts Compact Fluorescent Cat. # 2 (26W) N2MVF052/UNV 2 (32W) N2MVF064/UNV III. Globe, Guards, and Reflectors: Cat. # Globe G303 Globe Teflon Coated G303S808 Globe Guard P33 Reflector Dome RD739 Reflector Angle RA739 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 5L Type 1079 1080-1081.qxp 5L 12/16/2013 6:50 PM Page 1080 N2MVF Series Compact Fluorescent Family Tree Champ® Non-metallic Luminaires A complete luminaire consists of a cover mount, a ballast housing and a globe, with or without guard, refractor or reflector. 5L All Components are suitable for use in ordinary locations, Class I, Div. 2 and wet locations. 1080 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1080-1081.qxp 12/16/2013 6:50 PM Page 1081 N2MVF Series Compact Fluorescent 5L Dimensions Weights Champ® Non-metallic Luminaires Dimensions In Inches: Ceiling Mount – Top View 25° Angle Stanchion Mount Ceiling Mount 5L Pendant Mount Net Luminaire Weights: Luminaire Series Lamp Watts Luminaire with Mounting Module, Globe, Guard & Refractor (lbs.) N2MVF052 N2MVF064 52 64 30 30 Accessories: Reflectors (to be used with globe) Type Cat. # Dome 30° Angle RD739 (RD79) RA739 (RA79) To be ordered separately. Wall Arm Mount www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1081 1082-1083.qxp 12/16/2013 5L 6:51 PM Page 1082 Photometric Data N2MVF Series Compact Fluorescent Champ® Non-metallic Luminaires N2MVF Photometric Data Isofootcandle Chart: Luminaire with globe and dome reflector N2MVF064GRD Dome Reflector Note: For 52 watt N2MVF applications, use a .75 multiplier. 5L Footcandle Values for Isofootcandle Lines Mounting Height A B C D E 8' 10' 12' 16' 4.00 2.56 1.78 1.00 2.00 1.28 0.89 0.50 1.00 0.64 0.44 0.25 0.50 0.32 0.22 0.13 0.25 0.16 0.11 0.06 N2MVF064GRD Dome Reflector Coefficients of Utilization Effective Floor Cavity Reflectance 20% Room Cavity Ratio Eff. Ceil. Wall 1 2 3 4 5 6 7 8 9 10 80* 50* 30* 10* .741 .694 .652 .617 .548 .491 .524 .445 .382 .452 .370 .308 .396 .314 .254 .351 .271 .214 .314 .237 .183 .283 .210 .159 .258 .188 .140 .236 .169 .125 70* 50* 30* 10* .722 .679 .640 .601 .537 .483 .510 .437 .378 .440 .364 .305 .386 .309 .252 .342 .267 .212 .307 .234 .182 .277 .207 .158 .252 .185 .139 .231 .167 .124 50* 50* 30* 10* .686 .650 .617 .570 .516 .470 .484 .421 .369 .418 .351 .299 .367 .299 .247 .326 .259 .209 .293 .227 .180 .265 .202 .155 .242 .181 .138 .223 .163 .123 30* 50* 30* 10* .653 .623 .596 .542 .497 .457 .460 .406 .361 .398 .340 .293 .350 .290 .243 .311 .251 .206 .280 .221 .177 .254 .197 .154 .233 .176 .136 .214 .160 .121 10* 50* 30* 10* .622 .598 .576 .516 .478 .444 .437 .392 .352 .379 .329 .287 .333 .271 .239 .297 .244 .203 .268 .215 .175 .244 .192 .152 .224 .172 .135 .206 .156 .120 0* 0* .557 .424 .332 .267 .220 .184 .157 .136 .119 .105 *Percent Reflectance. 1082 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1082-1083.qxp 12/16/2013 6:51 PM Page 1083 EVLPF Series Compact Fluorescent Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence Low Profile Hazard•Gard® Luminaires Marine & Wet Locations 3, 3R, 4, 4X; IP66 5L Applications: Eaton's Crouse-Hinds Low Profile Hazard•Gard® luminaires are used in: • Areas where flammable or explosive vapors or gases are present • Hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired • Petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities • Waste treatment facilities • Drilling platforms and other coastal and offshore hazardous areas Features and Benefits: Certifications and Compliances: • NEC and CEC: Class I, Division 1, Groups B (GB suffix), C, D Class I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards C22.2 No. 137 Standard Materials: Standard Finishes: • Copper-free aluminum – Corro-free™ powdered epoxy • Krydon – white • Stainless steel guard Ratings (Electrical/Size): Sources/Wattage: • 52W (two 26W lamps) & 64W (two 32W lamps) • 120–277V, 50–60Hz • 347V, 60Hz • 12, 24, 125 VDC Conduit Entries: • 3/4", 1" NPT – Pendant, Wall Bracket, Ceiling • 11/4" NPT – Stanchion • Mounting modules, cover, ballast housing, globe holder – copper-free aluminum • Globe – heat- and impact-resistant glass • Exterior hardware – stainless steel • Reflectors (dome & angle) – Krydon® fiberglass-reinforced polyester Options: Description Suffix Group B suitability .......................................................................................................... GB Fused (not suitable for marine applications) .................................................................... S658 Factory assembled with lamps ........................................................................................ FA Accessories: Description Cat. # Dome reflector ................................................................................................................ RD739 Angle reflector ................................................................................................................ RA739 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1083 5L • Small, compact size • Two start Acme threaded construction • Lightweight copper-free aluminum housing with powdered epoxy finish • All exterior hardware is corrosionresistant stainless steel • Four mounting arrangements - pendant, ceiling, wall bracket, and stanchion • Wide range of light sources and wattages • Marine and NEMA 4X construction • Integral ballast • High power factor (90%+) ballasts • Uses same mounting modules as the standard Hazard•Gard® • Internally fluted glass globes • Krydon® construction dome and angle reflectors – won't rust, corrode, dent, chip, or peel • Now available in components – luminaire body, mounting module, guard, reflectors • Three wire construction is standard on fluorescent emergency lighting • Perfect where low mounting restrictions are a concern • Easier assembly, installation and maintenance • Superior corrosion resistance • Suit any lighting layout • Meet specific lighting needs • Outdoor, hose down, marine, and corrosive environments suitable • Lowest installed cost • Allows more luminaires per circuit • Easy retrofitting when the EVLPF is the preferred choice • Reduces glare and distributes light evenly – ideal for adverse environments typical of industrial facilities • Easily stocked for quick ship requirements • For energy conservation, luminaires can be switched off without affecting the emergency operation feature 1084-1085.qxp 5L 12/16/2013 6:51 PM Page 1084 EVLPF Series Compact Fluorescent Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence Low Profile Hazard•Gard® Luminaires Pendant Wall Bracket* Ceiling* Marine & Wet Locations 3, 3R, 4, 4X; IP66 Luminaire Body Less Mounting Module & Guard Stanchion Hub With Guard With Guard With Guard With Guard Watt Size (In.) Cat. # Cat. # Cat. # Cat. # Cat. # Fluorescent—High Power Factor Ballast (Min. P.F. 90%) 3 EVLPFA02521 EVLPFBX02521 EVLPFCX02521 EVLPF0520 /4 EVLPFA03521 EVLPFBX03521 EVLPFCX03521 52W 1 EVLPFJ04521 11/4 /4 1 11/4 3 64W EVLPFA02641 EVLPFBX02641 EVLPFA03641 EVLPFBX03641 EVLPFCX02641 EVLPFCX03641 EVLPF0640 EVLPFJ04641 Pendant Mount Pendant Wall Bracket* Hub Without Guard Without Guard Watt Size (In.) Cat. # Cat. # Fluorescent—High Power Factor Ballast (Min. P.F. 90%) 3 EVLPFA02520 EVLPFBX02520 /4 EVLPFA03520 EVLPFBX03520 52W 1 11/4 /4 1 11/4 3 64W EVLPFA02640 EVLPFA03640 EVLPFBX02640 EVLPFBX03640 Ceiling* Without Guard Cat. # EVLPFCX02520 EVLPFCX03520 EVLPFJ04520 EVLPFCX02640 EVLPFCX03640 EVLPFJ04640 Complete Catalog Number as follows: *Wall Bracket Mount 1. Voltages - Add suffix as follows: Standard Voltage Ballasts - 60Hz Optional Ballasts NEC/UL & CEC/CSA (cUL) CEC/CSA (cUL) 120–277V 50–60Hz /UNV 347V 60 Hz /347 125V DC /125VDC 12V DC /012VDC 5L Voltage Suffix *Ceiling Mount Stanchion Mount *Ceiling and bracket mounts have 4 hubs: 3 are plugged. 1084 www.crouse-hinds.com US: 1-866-764-5454 Stanchion Without Guard Cat. # CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 24V DC /024VDC 1084-1085.qxp 12/16/2013 6:51 PM Page 1085 EVLPF Series Ordering By Components 5L EVLP Luminaires are available in components. A complete light fixture consists of: I. Mounting Module II. Fixture Body III. Guard, Dome Reflector, Angle Reflector, or Exit Sign Mounting Modules: Type Pendant Ceiling & Wall Box Wall Bracket Arm Stanchion Guards Fluorescent Conduit Cat. # 3 /4" 1 EVMP2 EVMP3 3 /4" 1 EV22 EV33 Use EV22 or EV33 box with EV87 11/4" EV87 EVMJ4 EV512 Reflectors Dome Angle RD739 RA739 Pendant Ceiling Stanchion Ceiling Wall Bracket EVMP2 EVMP3 EV22 EV33 EVMJ4 EV22 EV33 EV87 & EV22 or EV33 5L Fixture Body EVLPF0520/UNV EVLPF0521/UNV EVLPF0640/UNV EVLPF0641/UNV Guards Dome Reflector Angle Reflector EV512 RD739 RA739 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1085 1086-1087.qxp 12/16/2013 5L 6:51 PM Page 1086 Dimensions and Weights EVLPF Series Compact Fluorescent Low Profile Hazard•Gard® Luminaires Temperature Performance Data: Fluorescent Fixtures Maximum Ambient Fluorescent 52W & 64W Class I, Group B (w/GB suffix) Groups C, D Class I, Zone I 40°C Class II, Groups E, F, G Class III Simultaneous Presence 40°C Supply Wire °C Minimum Operating Temperature T6 T6 75°C –18°C Dimensions 5L In Inches: Fluorescent A B 15.69 14.69 C D 18.25 18.46 E F 22.34 21.30 Weights: Item Lbs. Fluorescent (EVLPF) 31.5 Add Mounting Modules: Pendant Ceiling Bracket Stanchion 1 2 4.5 2.5 Add For Reflectors & Exit Sign: RA739 RD739 DMVF–EXD Deduct .5 lb for Wire Guard 1086 www.crouse-hinds.com US: 1-866-764-5454 1 1 5 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1086-1087.qxp 12/16/2013 6:52 PM Page 1087 EVLPF Series Compact Fluorescent 5L Photometric Data Low Profile Hazard•Gard® Luminaires Luminaire with Globe and Guard EVLPFA03641 Two 32 W Compact Fluorescent 5L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1087 1088-1089.qxp 5L 12/16/2013 6:52 PM Page 1088 EVLPF Series Compact Fluorescent Photometric Data Low Profile Hazard•Gard® Luminaires Luminaire with Globe and Dome (Less Guard) EVLPFA03640RD Lamp: Two 32 W Compact Fluorescent Luminaire with Globe and 30° Angle Reflector (Less Guard) 5L EVLPFA03640RA Lamp: Two 32 W Compact Fluorescent 1088 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1088-1089.qxp 12/16/2013 6:52 PM Page 1089 FVS Series Long Twin Tube Fluorescent Luminaires 5L Marine & Wet Locations 3, 3R, 4, 4X; IP66 Cl. I, Div. 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III, Simultaneous Presence Applications: Size Ranges: FVS Compact Fluorescent Luminaires are used: • Where low mounting heights or limited mounting room exists • For task oriented lighting • Where a cool, efficient light source is required • In areas that require lamps to reach full illumination immediately • In industrial and chemical processing • In pulp and paper facilities • In waste or sewage treatment facilities • In non-hazardous commercial and industrial areas • In food and pharmaceutical plants where a non-glass lens is required • Where fluorescent lighting has been preferred, but unavailable due to limited space and practicality • All luminaires are 24" L x 12" W x 3.12" H • Conduit entrances are 3/4" Features: Standard Materials: • Corrosion-resistant die cast copper-free aluminum housing • Shatter-resistant nylon lens • Polycarbonate lens (suffix -S813) • Silicone rubber gasket • Extruded aluminum hinges and closure hardware with stainless steel pivots • UNV (120–277V), 50–60 Hz • 347V, 60 Hz • Two 40 watt long twin tube lamps Accessories Certifications and Compliances: • NEC and CEC: Class I, Division 2, Groups B, C, D Class II, Division 1, Groups E, F, G (Suffix S813) Class II, Division 2, Groups F, G Class III & Simultaneous Presence (Cl. I and Cl. II) Note: Aiming Limitations Cl. II, Cl. III & Simultaneous Presence Aim down to Horizontal Cannot aim up • UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards C22.2 No. 137 FVS Trunnion Mount Kit (FVS-K5) • Permits vertical mounting of luminaire on a beam when used with a standard beam clamp • Can be mounted directly to a wall or ceiling • Can be pole mounted when used in conjunction with a SFA6 slipfitter adapter (ordered separately) • Constructed from copper-free aluminum • Supplied with a CGB cord connector FVS with Trunnion Arm and Slipfitter 5L • Compact, lightweight, low profile design is ideal for confined areas and tight corners • Reaches full illumination immediately and delivers light output equivalent to fixtures twice its size • Fast-Latch™ closure provides quick and easy access for relamping and maintenance – no tools necessary • Silicone sealing gasket provides exceptional watertight and dust-tight bond, providing excellent performance in wet and corrosive environments • Power disconnect switch (Eaton's Crouse-Hinds ESWP) automatically cuts power to the lamps and ballast when the lens is opened • Shatter-resistant polymeric lens (0.125 thick) provides environmental and corrosion protection • Available in UNV (120-277) and 347 50/60 Hz voltages • Two lamp fixture, uses single-ended 40 watt lamps • Multiple mounting capability • Energy saving electronic ballast is standard Electrical Ratings: Options: Description Suffix • Fused to protect ballast under abnormal line conditions (not available on CSA certified fixtures) (not suitable for marine applications) ................................................ S658 • Fixture supplied with two F40BX/SPX35 lamps ........................................................... S714 • Corro-free™ epoxy finish inside and out ...................................................................... S753 • Tamperproof ..................................................................... Consult Eaton's Crouse-Hinds Temperature Performance Data: Ambient Style Temp °C All 40°C All 55°C Class I, Div. 2 Simultaneous Class II Presence See Aiming Limitations Supply Wire Minimum Operating Temperature T3C T3C T6 — 75°C 75°C –18°C (0°F) –18°C (0°F) T3C/T6 — Luminaire Weight: Without Lamps Type Standard 2 lamp FVS lbs. 12.0 Standard Finishes: • Epoxy powder coated housing • Anodized hinges and closure hardware • Highly specular aluminum reflector www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1089 1090-1091.qxp 12/16/2013 5L 6:52 PM Page 1090 Cl. I, Div. 2, Groups B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III, Simultaneous Presence FVS Series Long Twin Tube Fluorescent Luminaires Marine & Wet Locations 3, 3R, 4, 4X; IP66 Luminaire includes all necessary provisions for these installations: Ceiling Mount Pendant Mount Corner Mount Horizontal Wall Mount FVS compact fluorescent (2 lamp luminaire): Voltage Wattage/ Lamp Hub Size (4) Cat. # Cat. # with Class II, Div. 1 Suitability 120–277 (50 or 60 Hz) 347 (50 or 60 Hz) 40 40 3 /4" 3 /4" FVS20/UNV FVS23 FVS20/UNV S813 FVS23 S813 Accessories (Ordered Separately): Description Cat. # • Trunnion arm kit • Slipfitter adapter to be used with trunnion arm FVS K5 Dimensions: FVS with Trunnion Arm: 261/4" x 13.5" W x 3.12" H 5L Top View Side View FVS With Lens Open 1090 www.crouse-hinds.com US: 1-866-764-5454 FVS Showing Mounting Strap Positioning CAN: 1-800-265-0502 Vertical Wall Mount Copyright© 2013 Eaton’s Crouse-Hinds Business SFA6 1090-1091.qxp 12/16/2013 6:52 PM Page 1091 Photometric Data FVS Series Long Twin Tube 5L Fluorescent Luminaires Luminaire: FVS Lamp: (2) F40BX/SPX35/RS single-ended fluorescent. Total initial lumens: 6300 Coefficients of Utilization Isofootcandle Chart Effective Floor Cavity Reflectance 20% Room Cavity Ratio Wall 1 2 3 4 5 6 7 8 9 10 50* 30* 10* .621 .594 .569 .538 .495 .459 .469 .419 .378 .414 .359 .317 .367 .312 .270 .329 .273 .234 .297 .242 .204 .269 .216 .180 .246 .195 .160 .225 .176 .144 70* 50* 30* 10* .606 .582 .560 .526 .487 .453 .459 .412 .374 .405 .354 .314 .360 .308 .268 .323 .270 .232 .291 .240 .203 .265 .214 .179 .242 .193 .160 .222 .175 .143 50* 50* 30* 10* .580 .560 .541 .503 .470 .442 .441 .400 .367 .389 .345 .310 .347 .300 .265 .311 .265 .230 .281 .235 .201 .256 .210 .178 .234 .190 .159 .216 .172 .143 30* 50* 30* 10* .555 .539 .524 .483 .455 .431 .423 .389 .360 .374 .336 .305 .334 .293 .262 .301 .259 .227 .272 .230 .199 .248 .207 .176 .227 .187 .157 .210 .170 .142 10* 50* 30* 10* .533 .520 .507 .464 .441 .421 .407 .378 .353 .361 .327 .300 .322 .287 .258 .290 .254 .225 .264 .226 .197 .241 .203 .175 .221 .184 .156 .204 .167 .141 0* 0* .494 .407 .339 .286 .245 .212 .185 .163 .145 .130 Footcandle Values for Isofootcandle Lines Mtg. Hgt. 8' 10' 12' 16' A B C D E 5.00 3.20 2.22 1.25 3.00 1.92 1.33 0.75 1.00 0.64 0.44 0.25 0.50 0.32 0.22 0.13 0.20 0.13 0.09 0.05 Spacing to Mounting Height Ratio Along lamp axis (A-A) Across lamp axis (B-B) 0.6 1.1 *Percent Reflectance. †FVS suitable for Class II, Div. 1, Groups E, F, G when ordered with suffix S813. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1091 5L Eff. Ceil. 80* 1092-1093.qxp 12/16/2013 5L 6:52 PM Page 1092 EVFT Illuminator™ Long Twin Tube Fluorescent Luminaires Cl. I, Div. 1, Groups B & C (suffix GB), D Cl. I, Zone 1, Group IIB + H2 (suffix GB), IIA Cl. II, Div. 1, Groups E, F, G Cl. III Simultaneous Presence Paint Spray Marine & Wet Locations 3, 3R, 4, 4X; IP66 Applications: Illuminator™ Compact Fluorescent Luminaires are used: • In areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitable fibers and flyings • In areas where combustible dusts and flammable gases are present simultaneously • In applications involving low mounting heights, restricted mounting space, or where luminaire weight must be minimized • In areas where corrosion, vibration, moisture, dirt, and rough usage are a problem • In refineries, chemical and petrochemical facilities, grain processing, handling and storage facilities, manufacturing plants, wastewater treatment facilities, airline and mass transit maintenance areas, paint spray facilities, breweries, pharmaceutical plants, and other areas where safe, reliable hazardous area lighting is required in a compact, cool operating and efficient light source 5L Features: • Efficient fluorescent light source in 78 and 156 watts • Adjustable right and left asymmetrical reflectors provide excellent light "aimability" – ideal for task oriented lighting • Compact, lightweight, and low profile design allows easy installation and broad industrial application • Cast copper-free aluminum with epoxy powder finish (less than 0.4 of 1% copper) provides excellent resistance to corrosion • Versatile luminaire housing provides choice of pendant, wall, or ceiling mount • Suitable for paint spray areas; linear light source provides excellent color rendition for paint spray tasks; easy to install, disposable, clear tube wrap helps maintain maximum light output during painting operations • Threaded construction, factory wiring and sealing help minimize installation time; no external seals are required • Fixtures are used with two or four long twin tube single-ended fluorescent lamps • Optional stainless steel guard provides extra protection for lamps and lamp tube • Optional clear polycarbonate tube provides 360° protection for lamps and lamp tube; ideal for maintenance pit and pharmaceutical applications • Grounding connection for safety • Available for 120 or 277 VAC • Standard electronic ballast 1092 www.crouse-hinds.com US: 1-866-764-5454 4 lamp with stainless steel wire guard and adjustable reflectors Options: Certifications and Compliances: • NEC and CEC: Class I, Division 1, Group D Class I, Division 1, Group B, C, D (suffix GB) Class I, Zone 1, Group IIA Class I, Zone 1, Group IIB + H2 (suffix GB) Class II, Groups E, F, G Class III Simultaneous Presence (Cl. I and Cl. II) Paint Spray Note: Aiming Limitations Cl. II, Cl. III & Simultaneous Presence - Aim Down to Horizontal - Cannot aim up • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 Description Suffix Fused to protect circuit under abnormal conditions (not available on CSA certified luminaires) (not suitable for marine applications) ....... S658 Luminaire supplied with lamps.......... S714 Class I, Groups B and C suitability pendant mount only .......................... GB Electrical Ratings: • Input voltage – 120 or 277 VAC, 60 Hz • Wattages – 78 – 2 lamp luminaire 156 – 4 lamp luminaire Fixture Weights Illuminator lbs. 2 lamp with guard ............................. 19.5 4 lamp with guards ........................... 36.5 RAL1, RAR1 reflectors (each) ........... 3.0 Deduct for luminaire without P51 Guard: 1 lb. for 2 lamp 2 lbs. for 4 lamp Standard Materials: • Center and ballast housings, end caps – copper-free aluminum • Lamp tube – heat-resistant glass • Guards – stainless steel or clear polycarbonate material • Reflectors – aluminum Standard Finishes: • Center and ballast housings, end caps, guards – natural • Reflectors – white epoxy finish Temperature Performance Data: Luminaire Type 2 and 4 Lamp Minimum Operating Temp. Maximum Ambient Temp. Class I, Division 1 & Zone 1 Class II, Division 1 Supply Simultaneous Presence Wire 10°C (50°F) 40°C (104°F) T4A CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 75°C 1092-1093.qxp 12/16/2013 6:52 PM Page 1093 Cl. I, Div. 1, Groups B & C (Suffix B), D Cl. I, Zone 1, Groups IIB + H2 (Suffix B), IIA Cl. II, Div. 1, Groups E, F, G Cl. III, Simultaneous Presence EVFT Illuminator™ Long Twin Tube Fluorescent Luminaires Paint Spray Marine & Wet Locations 3, 3R, 4, 4X; IP66 5L Ordering Information: Style Luminaire Voltage Without Guard With P51 Guard† Without Guard With P51 Guard† /4 /4 120 277 EVFT22320 EVFT22370 EVFT22321 EVFT22371 EVFT22320 GB EVFT22370 GB EVFT22321 GB EVFT22371 GB /4 /4 120 277 EVFT24320 EVFT24370 EVFT24321 EVFT24371 EVFT24320 GB EVFT24370 GB EVFT24321 GB EVFT24371 GB 3 3 4 Lamp Class I Cat. # with Group B, C & D Suitability Hub Size (In.) 3 2 Lamp Class I Cat. # with Group D Suitability 3 †P51 supplied in separate carton. Accessories: Type Aiming Limitations: Cat. # • • • • Stainless steel wire guard.......... P51 Reflector right hand ................... RAR1 Reflector left hand...................... RAL1 Polycarbonate tube (not used with optional stainless steel wire guard) ........................ PG1 • Disposable clear wrap – 5 pack (for use with optional polycarbonate tube) ................... PTW1 In Class II, Class III and Simultaneous Presence locations • Aim down to horizontal • To prevent dust from accumulating in reflector, do not aim up • The Illuminator lighting fixtures are designed for operation with the lamp in a horizontal to base down position Dimensions: RAL1 RAR1 Reflectors (as viewed facing front of fixture) Note: For 4 lamp unit, you must order one of each refractor, if required. Illuminator two lamp luminaire with reflector 5L Stainless steel guard Polycarbonate tube and retaining plate Illuminator four lamp luminaire with reflectors Disposable polyester tube wrap (used over optional polycarbonate tube) ‡For GB suffix (Groups B & C) this dimension is 34.0". For CSA certified fixtures this dimension is 359/ 16". ■For GB suffix (Groups B & C) this dimension is 8.38". www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1093 1094-1095.qxp 5L 12/16/2013 6:53 PM Page 1094 Photometric Data EVFT Illuminator™ Long Twin Tube Fluorescent Luminaires Illuminator two lamp luminaire with reflector (without guard) Lamps: Two 39 watt BIAX* fluorescent Footcandle Values for Isofootcandle Lines Mtg. Ht. (ft.) 8 10 12 16 A B C D E F 10.0 6.4 4.4 2.5 5.00 3.20 2.22 1.25 2.00 1.28 0.89 0.50 1.00 0.64 0.44 0.25 0.50 0.32 0.22 0.13 0.25 0.16 0.11 0.06 Illuminator four lamp luminaire with reflectors (without guards) 5L Lamps: Four 39 watt BIAX* fluorescent Footcandle Values for Isofootcandle Lines Mtg. Ht. (ft.) 10 12 16 20 *BIAX is a trademark of the General Electric Company. 1094 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business A B C D E F 8.0 5.6 3.1 2.0 4.00 2.78 1.56 1.00 2.00 1.39 0.78 0.50 1.00 0.69 0.39 0.25 0.50 0.35 0.20 0.13 0.20 0.14 0.08 0.05 1094-1095.qxp 12/16/2013 6:53 PM Page 1095 EVFT Illuminator™ Long Twin Tube 5L Coefficients of Utilization Fluorescent Luminaires Luminaire: EVFT 22320 with RAR1 Reflector Lamps: Two F39BX/SPX35/RS Lumen Rating: 2900 Lumens/Lamp Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 0 1 2 3 4 Room Cavity Ratio 5 6 7 8 9 10 80 70 50 30 10 .51 .51 .51 .51 .46 .44 .41 .40 .41 .38 .35 .32 .38 .33 .29 .26 .34 .29 .25 .22 .31 .25 .21 .18 .29 .23 .19 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .13 .10 .21 .15 .11 .09 70 70 50 30 10 .49 .49 .49 .49 .45 .43 .41 .39 .40 .37 .34 .31 .37 .32 .29 .26 .33 .28 .25 .22 .30 .25 .21 .18 .28 .22 .18 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .12 .10 .20 .14 .11 .09 50 50 30 10 .47 .47 .47 .41 .39 .38 .35 .33 .31 .31 .28 .26 .27 .24 .22 .24 .21 .18 .21 .18 .16 .19 .16 .13 .17 .14 .12 .15 .12 .10 .14 .11 .09 30 50 30 10 .45 .45 .45 .39 .38 .37 .34 .32 .30 .30 .27 .25 .26 .24 .21 .23 .20 .18 .21 .18 .15 .19 .16 .13 .17 .14 .11 .15 .12 .10 .14 .11 .09 10 50 30 10 .43 .43 .43 .37 .36 .35 .33 .31 .29 .29 .27 .25 .25 .23 .21 .22 .20 .18 .20 .17 .15 .18 .15 .13 .16 .13 .11 .14 .12 .10 .13 .10 .08 0 0 .43 .35 .28 .24 .20 .17 .14 .12 .10 .09 .08 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES Luminaire: EVFT 24320 with RAR1 & RAL1 Reflectors Lamps: Four F39BX/SPX35/RS Lumen Rating: 2900 Lumens/Lamp 2 3 4 Room Cavity Ratio 5 6 7 8 9 10 80 70 50 30 10 48 .48 .48 .48 .44 .42 .40 .39 .40 .37 .34 .31 .37 .32 .29 .26 .33 .29 .25 .22 .30 .25 .21 .19 .28 .22 .19 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .13 .10 .20 .15 .11 .09 70 70 50 30 10 .47 .47 .47 .47 .43 .41 .40 .38 .39 .36 .33 .31 .36 .32 .29 .26 .33 .28 .25 .22 .29 .25 .21 .18 .27 .22 .18 .16 .25 .20 .16 .14 .23 .18 .14 .12 .21 .16 .12 .10 .20 .14 .11 .09 50 50 30 10 .45 .45 .45 .39 .38 .37 .34 .32 .30 .30 .28 .26 .27 .24 .22 .24 .21 .18 .21 .18 .16 .19 .16 .14 .17 .14 .12 .15 .12 .10 .14 .11 .09 30 50 30 10 .43 .43 .43 .38 .37 .36 .33 .31 .30 .29 .27 .25 .26 .23 .21 .23 .20 .18 .20 .18 .16 .18 .16 .13 .17 .14 .12 .15 .12 .10 .14 .11 .09 10 50 30 10 .41 .41 .41 .36 .35 .35 .32 .30 .29 .28 .26 .25 .25 .23 .21 .22 .20 .18 .20 .17 .15 .18 .15 .13 .16 .13 .12 .14 .12 .10 .13 .11 .09 0 0 .41 .34 .28 .24 .20 .17 .15 .13 .11 .09 .08 5L Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 0 1 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1095 1096-1097.qxp 5L 12/16/2013 6:53 PM Page 1096 Higher Ambient Suitability: 55°C Cold Weather Start (32W T8 Lamps) Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC NFL Series Fluorescent Luminaires Wet Locations 3, 3R, 4, 4X Applications: The NFL Light Luminaires are used: • In hazardous locations where dust, dirt, combustible vapors, smoke, fumes, moisture, corrosive, and wet conditions are present • Where lamps may be broken due to physical abuse or movable equipment, such as in manufacturing areas or warehouses • Where cleanliness and sanitation are prime factors such as in dairies, canneries, food processing plants, bottling plants, and laboratories • In dock areas for protection against salt spray • In areas where low mounting height and the even light distribution associated with a line type light source are required 5L Key Features: • UL, cUL Listed for Class I, Division 2, Groups A, B, C, D areas with ambient suitability of 40°C (104°F) and 55°C (131°F) ambient suitability • NEMA 4X with Myers Hubs and threaded metal plug (furnished) • Non-metallic construction enclosure is corrosion-resistant • Continuous form-in-place gasket ensures dust-tight, moisture-tight, and wet locations integrity • Molded-in-place mounting studs – eliminate the need of bracket gaskets • Standard construction includes: S.S. mounting brackets Electronic ballast Cold weather ballast (4' F32 T8) • S.S. mounting bracket combination ceiling and chain • S.S. mounting brackets provide superior corrosion resistance • Electronic ballast for energy efficiency • Cold Weather Ballast (4' F32 T8) • Two 1/2" conduit Myers Hubs for end and feed through wiring simplify installation and wiring • Full metal fixture interior provides improved photometrics as well as access to and concealment of ballast and wiring • Provisions (drill mark) on 4 ft. unit to field drill for pendant mounting for application and installation flexibility www.crouse-hinds.com Sources/Wattage: luminaires are for use with the following lamps • NFL2140 one 40 W long twin tube • NFL4232 two 32W T8 lamps • NFL4240 two 34W "F40 Style" T12 lamps Voltages • 120V 60Hz • 120 – 277V, 50 – 60 Hz • 347V 60 Hz Conduit Entries • Two 1/2" inch Myers hubs, one on each end Celecon™ is a trade name of Hoechst Celanese. Standard Finishes: • Fiberglass housing – white • Acrylic plastic lens – crepe pattern Options: Description Suffix • Fused (not suitable for marine applications) ............ S658 • Factory assembled with lamps installed .................... FA • Battery back-up emergency ballast† (NFL 2140 and NFL 4232 only).... S799* • Increased impact-resistant lens (acrylic crepe pattern).. DR1295046* • Stainless steel latches ........ S863* • Tamperproof latches........... S861* †For non-hazardous locations. *UNV voltages: 120, 208, 230, 240, 277, 50–60 Hz. Temperature Performance Data: Ambient temperature range suitability: Two lamp, 32W T8, 4 ft luminaire All others Supply wire US: 1-866-764-5454 °C -18°C to 55°C 0°C to 55°C 75°C min. Ordering Information: Size/# of Lamp(s) NFL2140/UNV Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC UL Listed 844 cUL Wet locations 4X 1096 Ratings (Electrical/Size): Luminaire Cat. # Certifications and Compliances: • • • • • • Standard Materials: • Housing – non-metallic, one piece fiberglass-reinforced polyester • Latches – Celcon™ acetal plastic • Lens – acrylic plastic • Gaskets – seamless thermoset polyurethane • Mounting Bracket – stainless steel NFL2140/347 2 ft/ 1-lamp Wattage/ Lamp type Voltage/Hz 40W T5 compact single ended 120 / 60 120–277/50–60 347 / 60 NFL4232/UNV 4 ft/2-lamp 32W T8 rapid start 120 / 60 120–277/50–60 NFL4240/120 NFL4240/277 NFL4240/347 4ft/2-lamp 34W T12 "F40 Style" rapid start 120 / 60 277 / 60 347 / 60 N2FL4232/UNV N2FL4232/347 4ft/2-lamp 32W T8 rapid start 347 / 60 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1096-1097.qxp 12/16/2013 6:53 PM Page 1097 NFL Series Fluorescent Luminaires 5L Photometric Data Luminaire: All NFL Luminaires Candlepower Distribution Curve (in Candelas) Zonal Lumens Candelas Angle Along Across Zone Lumens 0° 1049 1049 0–30 862 10° 1034 1056 0–40 1462 20° 978 1071 0–60 2778 30° 866 1075 0–90 4130 40° 762 1027 0–180 4499 50° 606 939 60° 416 838 70° 228 723 80° 92 549 90° 17 363 100° 19 243 110° 10 131 120° 5 46 130° 4 20 140° 4 9 150° 4 3 • Candlepower Distribution Curve (in candelas) and Zonal Lumens – These values are for all NFL series luminaires, adjusted by conversion factors (multipliers) below. 160° 4 0 Example: 170° 0 0 180° 0 0 • Candlepower at 20° across for NFL4232 using two (2) F32T/35K lamps (5700 lumen total) is 1071 candelas. Photometric data, developed using two (2) F32T8/35K 2850 lumen lamps, represents the performance of all NFL series luminaires. • Coefficient of Utilization – These values are for all NFL series luminaires (Do not use multipliers). • Candlepower at 20° across for NFL2140 using one (1) T5 compact lamp (3100 lumen total) is 1071 x .55 = 589 candelas. Lamp Qty NFL2140 NFL4232 NFL4240 2 2 1 Watts Type (Lumens ea.) Conversion Factor (multipliers) 32 34 40 F32T8/35K (2850) F40T12/RS (2650) T5 Compact (3150) 1.0 0.93 0.55 5L Luminaire Series Coefficient of Utilization: For all NFL Series Light Luminaires Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceiling Wall Room Cavity Ratio 1 2 3 4 5 6 7 8 9 10 80 70 50 30 10 .83 .78 .74 .71 .75 .67 .61 .56 .68 .59 .52 .46 .62 .52 .44 .39 .56 .45 .38 .32 .51 .40 .33 .28 .47 .36 .29 .24 .44 .32 .25 .20 .40 .29 .22 .17 .37 .26 .20 .15 70 70 50 30 10 .80 .76 .72 .69 .72 .65 .60 .55 .65 .57 .51 .46 .59 .50 .43 .38 .54 .44 .37 .32 .49 .39 .32 .27 .46 .35 .28 .23 .42 .31 .25 .20 .39 .28 .22 .17 .36 .26 .19 .15 50 50 30 10 .71 .68 .66 .61 .57 .53 .54 .48 .44 .47 .42 .37 .42 .35 .31 .37 .31 .26 .33 .27 .23 .30 .24 .20 .27 .21 .17 .24 .19 .15 30 50 30 10 .67 .65 .62 .58 .54 .51 .51 .46 .42 .45 .40 .36 .39 .34 .30 .35 .30 .26 .32 .26 .22 .28 .23 .19 .25 .20 .16 .23 .18 .14 10 50 30 10 .63 .61 .59 .54 .51 .48 .48 .44 .41 .42 .38 .35 .37 .33 .29 .33 .29 .25 .30 .25 .22 .27 .22 .18 .24 .19 .16 .22 .17 .14 0 0 .57 .46 .39 .33 .27 .23 .20 .17 .14 .12 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1097 1098-1099.qxp 12/16/2013 5L 6:54 PM Page 1098 NFL Series Fluorescent Luminaires Dimensions and Weights Dimensions: Net Luminaire Weights Luminaire Series Weight (lbs.) NFL2140 NFL4232 9.1 14.3 NFL4240 14.3 5L Temperature Performance Data: Lamp Type Supply Wire Temp. °C Class I, Div. 2 Temp. Rating Class II Temp. Rating Simultaneous Presence Class I, Div. 2 Cat. No. Watts Ambient Temp. °C NFL4232 NFL4232 32 32 40 55 T8 T8 60 75 T6 T5 - - NFL4240 34 40 T12 60 T6 - - NFL4240 34 55 T12 75 T5 - - NFL2140 40 40 T12 60 T6 - - NFL2140 40 55 T12 75 T5 - - 1098 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1098-1099.qxp 12/16/2013 6:54 PM Page 1099 eLLK Series™ Fluorescent Non-metallic Luminaires Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G (Canada) Cl. II, Div. 2, Groups F, G (US) Cl. III, Simultaneous Presence Wet Locations 3, 3R, 4, 4X; IP66 ATEX Certified 5L Applications: • eLLK Fixtures are used in hazardous areas where moisture or corrosion may be a problem • Offshore oil platforms, pharmaceuticals, plants, oil refineries • Where battery back-up is critical • In non-hazardous and industrial locations Features: Certifications and Compliances: • NEC and CEC: Class I, Division 2, Groups B, C, D Class I, Zone 1, Group IIC Class II, Division 1, Groups E, F, G (Canada) Class II, Division 2, Groups F, G (US) Class III, Simultaneous Presence (Cl. I and Cl. II) • UL Standards: 1598 Luminaires • CSA Standards: E79 Series • ATEX Directive 94/9/EC: Ex II 2 G Ex de IIC T4 Ex II 2 D Ex tD A21 IP66 T80°C • EC-Type Examination Certificate: BVS 09 ATEX E034 • GOST-R, GOST-K www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 5L • IEC: Zone 1 and 2 areas • NEC/CEC: Zone 1, Division 2 areas Electronic Ballast: • Operates at voltage range of 110–254 VAC ± 10%, 50–60 Hz • Wide ambient temperature range suitability -25°C to +55°C (eLLK92), -25°C to +50°C (eLLK92NIB) • Lamps operate independently – one lamp failure will not affect remaining lamp operation • Standard bi-pin lamps – most common lamp used in office enviroments; energyefficient and cost effective • Interlocked switch – automatically cuts power to both lamps and ballast when the lens is opened • Removable lens – hinged on both sides for easy installation and maintenance • Dual entries– extra large wire well eliminates need for separate junction boxes (own with cable gland and conduit hub) • Corrosion-resistant construction - nonmetallic body, gasketed lenses, and lens locking system for an IP66, NEMA 4X rating Battery Back-up Features: • Operates one lamp for 11/2 hours should power go out • Microprocessor monitors the charging functions of the battery • LEDs provide visual indication of battery life Copyright© 2013 Eaton’s Crouse-Hinds Business 1099 1100-1101.qxp 12/16/2013 5L 6:54 PM Page 1100 eLLK Series™ Fluorescent Non-metallic Luminaires Ordering Information: Cat. # Description Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 1, Group IIC Cl. II, Div. 1, Groups E, F, G (Canada) Cl. II, Div. 2, Groups F, G (US) Cl. III, Simultaneous Presence Length & Lamp Type Lamp Watt 2 Lamp Rated Voltage Rated Current Wet Locations 3, 3R, 4, 4X; IP66 ATEX Certified Conduit Hub Size* Comments NEC (NOT ATEX CERTIFIED) 1 2265 875 309 eLLK 92 2217 /U240 1/6 2 NPT 3/4" 2-foot T8 NEC 17W 120V-240V, 0.38-0.18A 50-60 Hz, 120-230 DC 2 ea. - 3/4" Myers hub No throughfeed 1 2265 875 310 eLLK 92 2217 /U240 1/6 2 NPT 1/2" 2-foot T8 NEC 17W 120V-240V, 0.38-0.18A 50-60 Hz, 120-230 DC 2 ea. - 1/2" Myers hub No throughfeed 1 2265 875 311 eLLK 92 2217 /U240 2/6 2 NPT 3/4" 2-foot T8 NEC 17W 120V-240V, 0.38-0.18A 50-60 Hz, 120-230 DC 4 ea. - 3/4" Myers hub Throughfeed 1 2266 875 309 eLLK 92 4232 /U240 1/6 2 NPT 3/4" 4-foot T8 NEC 32W 120V-240V, 0.7-0.34A 50-60 Hz, 120-230 DC 2 ea. - 3/4" Myers hub No throughfeed 1 2266 875 310 eLLK 92 4232 /U240 1/6 2 NPT 1/2" 4-foot T8 NEC 32W 120V-240V, 0.7-0.34A 50-60 Hz, 120-230 DC 2 ea. - 1/2" Myers hub No throughfeed 1 2266 875 311 eLLK 92 4232 /U240 2/6 2 NPT 3/4" 4-foot T8 NEC 32W 120V-240V, 0.7-0.34A 50-60 Hz, 120-230 DC 4 ea. - 3/4" Myers hub Throughfeed 1 2260 879 333 eLLK 92NIB 2217 /U120 2/6 2 NPT 3/4" 2-foot T8 NEC 17W 120V, 50-60 Hz, (with battery) 120-230 DC 0.38A 4 ea. - 3/4" Myers hub Throughfeed 1 2260 879 311 eLLK 92NIB 2217 /U240 2/6 2 NPT 3/4" 2-foot T8 NEC 17W 240V, 50-60 Hz, (with battery) 120-230 DC 0.18A 4 ea. - 3/4" Myers hub Throughfeed 4 ea. - 3/4" Myers hub 4 ea. - 3/4" Myers hub Throughfeed Throughfeed 1 2261 879 333 1 2261 879 311 eLLK 92NIB 4232 /U120 2/6 2 NPT 3/4" eLLK 92NIB 4232 /U240 2/6 2 NPT 3/4" 4-foot T8 NEC 4-foot T8 NEC 32W 120V, 50-60 Hz, (with battery) 120-230 DC 32W 240V, 50-60 Hz, (with battery) 120-230 DC 0.7A 0.34A 5L IEC (ATEX CERTIFIED) 1 2265 875 109 eLLK 92 018/18 1/6-1 M 2-foot T8 IEC 18W 120V-240V, 50-60 Hz 0.38-0.18A 2 ea. 20mm metric No throughfeed 1 2265 875 111 eLLK 92 018/18 2/6-2 M 2-foot T8 IEC 18W 120V-240V, 50-60 Hz 0.38-0.18A 4 ea. 20mm metric Throughfeed 1 2266 875 109 eLLK 92 036/36 1/6-1 M 4-foot T8 IEC 36W 120V-240V, 50-60 Hz 0.7-0.34A 2 ea. 20mm metric No throughfeed 1 2266 875 111 eLLK 92 036/36 2/6-2 M 4-foot T8 IEC 36W 120V-240V, 50-60 Hz 0.7-0.34A 4 ea. 20mm metric Throughfeed 1 2260 879 109 eLLK 92 018 /18NIB 1/6-1 M 2-foot T8 IEC 18W 240V, 50-60 Hz (with battery) 0.18A 2 ea. 20mm metric No throughfeed 1 2260 879 111 eLLK 92 018 /18NIB 2/6-2 M 2-foot T8 IEC 18W 240V, 50-60 Hz (with battery) 0.18A 4 ea. 20mm metric Throughfeed 1 2260 879 409 eLLK 92 018 /18NIB 1/6-1 M 2-foot T8 IEC 18W 120V, 50-60 Hz (with battery) 0.38A 2 ea. 20mm metric No throughfeed 1 2260 879 411 eLLK 92 018 /18NIB 2/6-2 M 2-foot T8 IEC 18W 120V, 50-60 Hz (with battery) 0.38A 4 ea. 20mm metric Throughfeed 1 2261 879 109 eLLK 92 036 /36NIB 1/6-1 M 4-foot T8 IEC 36W 240V, 50-60 Hz (with battery) 0.18A 2 ea. 20mm metric No throughfeed 1 2261 879 111 eLLK 92 036 /36NIB 2/6-2 M 4-foot T8 IEC 36W 240V, 50-60 Hz (with battery) 0.18A 4 ea. 20mm metric Throughfeed 1 2261 879 409 eLLK 92 036 /36NIB 1/6-1 M 4-foot T8 IEC 36W 120V, 50-60 Hz (with battery) 0.7A 2 ea. 20mm metric No throughfeed 1 2261 879 411 eLLK 92 036 /36NIB 2/6-2 M 4-foot T8 IEC 36W 120V, 50-60 Hz (with battery) 0.7A 4 ea. 20mm metric Throughfeed *2 hubs provided. May be connected through-feed or tandam. Cable glands ordered separately for / " (remove hubs) or M 25 openings (remove hubs). 3 4 Lamp Selection: Weights: NEC LAMP Type Phillips GE Osram/Sylvania 17W F17T8/Tl841 F17T8/SPX41 F017/841 32W F32T8/TL841 F32T8/SPX41 FO32/841 18W 3 2475 900 081 36W 3 2475 900 002 IEC LAMP Type CEAG 1100 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Watts 17W and 17W and 32W and 32W and Weight 18W 18W (with battery) 36W 36W (with battery) Copyright© 2013 Eaton’s Crouse-Hinds Business 4.6 Kg. (10 lb.) 10 Kg. (22 lb.) 6.7 Kg. (14 lb.) 12 Kg. (26 lb.) 1100-1101.qxp 12/16/2013 6:54 PM Page 1101 eLLK Series™ Fluorescent Non-metallic Luminaires Accessories: Accessories Dimensions 5L Dimensions In Millimeters: Eyebolt A2 Standard Luminaire with Back-up Hexagon Screw S4 Ceiling Mounting Bracket D92 Type Corrosion Protection Pipe DIN Outer Ø D (mm) Quantity per Luminaire Cat. # Eyebolt A2 Galvanized — — 2 2 2480 002 000 Hexagon Screw S4 Stainless Steel — — 2 2 2480 054 000 Ceiling Mounting Bracket D92 Stainless Steel — — 2 2 2480 092 000 Pipe Clamp R12 R14 R22 R32 11/4" 11/4" 11/2" 2" 38–42 38–42 47–51 56–60 2 2 2 2 2 2 2 2 Hexagon Key SW13 — eLLK 92 — — — 3 2485 000 005 Wall Bracket W27 — 42.4 1 2 2483 027 000 Hot Galvanized CrNi Hot Galvanized Hot Galvanized Hot Galvanized 2480 2480 2480 2480 462 464 472 482 000 000 000 000 5L Pipe Clamp Wall Bracket W27 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1101 1102-1103.qxp 12/16/2013 6:54 PM Page 1102 eLLK Series™ Fluorescent Non-metallic Luminaires 5L Photometric Data Photometric data developed using two (2) F32T8 3350 lumen lamps. For the 17W eLLK, use a 0.45 multiplier. Coefficient of Utilization 5L Effective Floor Cavity Reflectance 20% Room Cavity Ratio Eff. Ceil. Wall Work 1 2 3 80* 70* 20* 41 49 55 50* 20* 30 38 44 30* 20* 23 30 36 10* 20* 18 25 30 4 5 6 7 8 9 61 50 43 37 65 55 48 42 70 62 55 50 74 67 61 56 77 71 65 61 80 75 70 66 70* 70* 50* 30* 10* 20* 20* 20* 20* 40 29 22 18 47 37 30 24 53 42 35 30 58 49 42 36 62 54 47 42 68 60 54 49 71 65 59 54 74 68 64 59 77 72 68 64 50* 50* 30* 10* 20* 20* 20* 27 21 17 35 28 24 40 34 29 46 40 35 50 45 40 56 51 47 61 56 52 64 60 57 68 64 61 30* 50* 30* 10* 20* 20* 20* 26 20 17 38 27 23 37 32 28 43 38 34 47 43 39 58 49 45 57 53 50 60 57 54 64 61 58 10* 50* 30* 10* 20* 20* 20* 24 20 16 31 26 22 35 31 27 41 36 33 45 41 37 50 46 43 54 51 48 57 54 52 60 68 55 0* 0* 20* 14 20 25 31 35 41 46 49 53 *Percent Reflectance. 1102 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1102-1103.qxp 12/16/2013 6:54 PM Page 1103 CI. I, Div. 2, Groups A, B, C, D CI. I, Zone 2, AEx nA II CI. II, Div. 2, Groups F, G Enclosure Type 4X nLLK Series Non-metallic Fluorescent Luminaires Wet Locations UL and cUL Listed ATEX Certified 5L Eaton's Crouse-Hinds SpecOne™ nLLK Series Fluorescent Luminaire is an ideal source of general illumination indoors or out, in ordinary or hazardous environments. Its heavy duty, non-metallic construction stands up to tough physical and environmental demands, making it an excellent choice where dust, dirt, gas, vapor, smoke, fumes, moisture, corrosive and wet conditions are present. As with all SpecOne products, the nLLK Luminaire meets the standards and codes of regulating agencies throughout the world, which simplifies product specifying for multi-national users. Applications: Certifications and Compliances: • NEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx nA II Class II, Division 2, Groups F, G Wet Locations UL Listed • CEC: Class I, Zone 2, Ex nA II Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G cUL Listed (certified by UL) • Enclosure: Type 4X IP65 • UL Standards: 844 Hazardous (Zones Classified) Locations 1598 Luminaires • CSA Standards: C22.2 No. 9 CAN/CSA–E79-15 Standard Materials: • One-piece housing – fiberglassreinforced polyester • Lens – polycarbonate • Gasket – silicone Standard Finishes: • Fiberglass housing – natural (white) • Lens – natural (clear) Ratings (Electrical/Size): Sources/Wattages • Two (2) 17W or two (2) 32W linear fluorescent Voltages • 120–277 V, 50–60 Hz • 347 V, 60 Hz — consult factory Hub Size • Four 25 mm entries, two on each end, three plugged • Two Myers STM2 25 mm to 3/ 4" NPT adapter hubs provided standard for through-feed or tandem wiring ATEX • ATEX Directive 94/9/EC Ex II 3G Ex nA de IIC T4 Ex II 3G Ex nA de mb IIC T4 • Type of Protection Ex II 3D Ex tD A22 IP66 T80°C • EC-Type Examination Certificate BVS 09 ATEX E147 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1103 5L nLLK Series Luminaires are used: In indoor or outdoor, ordinary or hazardous areas Where a heavy duty, non-metallic luminaire is required to hold up to tough physical and environmental demands including corrosives, water, dust, and extreme temperatures • Manufacturing plants • Heavy industrial facilities • Industrial process facilities • Refineries • Chemical • Petrochemical • Pharmaceutical • Wastewater and sewage treatment plants In areas where low mounting height, immediate full illumination, and the even light distribution associated with a line type light source are required • Loading docks • Tunnels • Stairways Where wet location or Type 4X protection is required • Dock areas • Production platforms In hose down areas where cleanliness and sanitation are prime factors • Dairies • Canneries • Food processing plants • Bottling plants • Laboratories 1104-1105.qxp 12/16/2013 6:55 PM Page 1104 nLLK Series Non-metallic Fluorescent Luminaires 5L CI. I, Div. 2, Groups A, B, C, D CI. I, Zone 2, AEx nA II CI. II, Div. 2, Groups F, G Enclosure Type 4X Wet Locations UL and cUL Listed IP65, Type 4X heavy duty construction • Non-metallic body, gasketed lens and unique labyrinth lens locking system • Dust-tight, water-tight and moisture-tight • Corrosion and impact-resistant • Ideal for outdoor applications Electronic ballast • Lower ambient temperatures suitability to -18°C • High-power factor ballast (+90%) allows for more luminaires per circuit Standard T8 bi-pin lamps • Most common lamp used; energy-efficient and cost-effective Removable lens • Hinged on both sides for easy installation and maintenance Easy wiring and installation • Four 25 mm entries; two Myers™ 3/4" NPT adapter hubs supplied standard • Suitable for through-feed or tandem applications • Extra large wire well eliminates need for separate junction boxes Worldwide suitability • NEC/CEC: Class I, Zone 2 and Division 2 areas • IEC/CENELEC certified luminaires available (consult factory) Ordering Information: Cat. # Description Length & Lamp Type Lamp Watt - 2 Lamp Rated Voltage Rated Current Conduit Hub Size Comments 2-foot T8 2-foot T8 4-foot T8 4-foot T8 17W 17W 32W 32W 120V-277V, 60 Hz 347V, 60 Hz 120V-277V, 60 Hz 347V, 60 Hz 0.16A 0.16A 0.31A 0.31A 2 ea. - 3/4" Myers hub 2 ea. - 3/4" Myers hub 2 ea. - 3/4" Myers hub 2 ea. - 3/4" Myers hub Through-feed Through-feed Through-feed Through-feed 2-foot T8 2-foot T8 4-foot T8 4-foot T8 18W 18W 36W 36W 220V-240V, 50-60 Hz 220V-240V, 50-60 Hz 220V-240V, 50-60 Hz 220V-240V, 50-60 Hz 0.16A 0.16A 0.31A 0.31A 2 ea. - 25mm metric 2 ea. - 20mm metric 2 ea. - 25mm metric 2 ea. - 20mm metric Through-feed Through-feed Through-feed Through-feed NEC (NOT ATEX CERTIFIED) 1 3465 217 021 1 3465 217 347 1 3465 232 021 1 3465 232 347 nLLK 98 2217 /UNV nLLK 98 2217 /347 2/5 2 NPT 3/4" M UL nLLK 98 4232 /UNV nLLK 98 4232 /347 2/5 2 NPT 3/4" M UL 5L IEC (ATEX CERTIFIED) 1 3465 218 011 1 3465 218 021 1 3465 236 011 1 3465 236 021 nLLK 08 018/18 nLLK 08 018/18 nLLK 08 036/36 nLLK 08 036/36 Accessories: Description Cat. # SW13 hexagon key (for maintenance and lamp replacement) Myers™ 25mm to 3/4" NPT adapter hub 3 2485 000 005 STM 2 Type Corrosion Protection Pipe DIN Outer Ø D (mm) Quantity per Luminaire Eyebolt A2 Galvanized — — 2 2 2480 002 000 Hexagon Screw S4 Stainless Steel — — 2 2 2480 054 000 Ceiling Mounting Bracket D92 Stainless Steel — — 2 2 2480 092 000 Pipe Clamp R12 R14 R22 R32 11/4" 11/4" 11/2" 2" 38–42 38–42 47–51 56–60 2 2 2 2 2 2 2 2 Hexagon Key SW13 eLLK 92 — — — — 3 2485 000 005 Wall Bracket W27 Hot Galvanized — 42.4 1 2 2483 027 000 1104 www.crouse-hinds.com Hot Galvanized CrNi Hot Galvanized Hot Galvanized US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Cat. # 2480 2480 2480 2480 462 464 472 482 000 000 000 000 1104-1105.qxp 12/16/2013 6:55 PM Page 1105 nLLK Series Non-metallic Fluorescent Luminaires CI. I, Div. 2, Groups A, B, C, D CI. I, Zone 2, AEx nA II CI. II, Div. 2, Groups F, G Enclosure Type 4X Wet Locations UL and cUL Listed 5L Photometric Data: Accessories: Eyebolt A2 Temperature Performance: Supply Wire Temp.°C 60 60 Hexagon Screw S4 5L Minimum Starting Temperature: -18°C Class I, Div. 2 Class II, Div. 1 (CEC) Watts Ambient (Class I, Zone 2) Class II, Div. 2 (NEC) Two 17W T8 lamps 40°C T4 T6 Two 32W T8 lamps 40°C T4 T6 Maintenance and Relamping: (eLLK Series Div. 1/Zone 1 luminaire is shown. Maintenance procedures are the same for the nLLK.) 1.One quarter turn with the SW13 hexagon key or a 5/16" (M8) Allen hex head wrench releases multiple locking points. 2.Lamps can be stored in open lens, freeing up hands for easy relamping. 3.Replace the bi-pin lamp lock with one quarter turn of the wrench for an IP65, Type 4X seal. Ceiling Mounting Bracket D92 Dimensions (mm) and Weight: Weight: 8.8 lbs. (4.0 kg.)—18W 13.2 lbs. (6.0 kg.)—36W Pipe Clamp Wall Bracket W27 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1105 1106-1107.qxp 12/16/2013 5L 6:55 PM Page 1106 CI. I, Div. 2, Groups A, B, C, D CI. I, Zone 2, Group IIC CI. II, Div. 1, Groups F, G CI. III & Simultaneous Presence FVN Series Fluorescent Luminaires Wet Locations NEMA 3, 3R Applications: FVN Luminaires are ideal for use: • In areas made hazardous by the abnormal conditions resulting in the presence of flammable vapors or gases and combustible dusts as defined by the National Electrical Code® • Where broken lamps would damage machinery or processes, or harm people working in the area • In areas where stringent sanitation requirements exist Features: • One-piece seamless sheet steel housing with welded end caps keeps dirt, dust and moisture away from ballast and lamps; easy to clean • A silicone rubber gasket provides a dust-tight seal between the lens/frame assembly and housing • Lens/frame assembly is hinged and wireway cover is held by safety chain for ease of lamp replacement and maintenance • Polyester powder coat finish provides high reflectance and corrosion resistance for long life and dependable service • Two 1/ 2" NPT pendant hubs and two 1/2" NPT thru-feed end hubs are standard • Electronic ballast is standard on 32 and 54 watt luminaires (/UNV only) FVN Fluorescent Luminaires with T5 HO lamps offer: • High lumen output per watt – provides energy savings versus other higher wattage fluorescent luminaires with similar lumen output • Longer lamp life and good lumen maintenance – reduced maintenance and lamp replacement costs • • • • • • • Luminaire housing – 20-gauge seamless sheet steel Lens/frame assembly – stainless steel Glass – 3/ 16" tempered Suspension flanges – seamless sheet steel Gaskets – silicone Lampholders – white thermoset plastic Clamps – stainless steel Standard Finishes: • Reflector housings – corrosion-resistant white polyester powder coat • Lens/frame – natural Dimensions In Inches: 40” Certifications and Compliances: 5L Standard Materials: 8 1/2” • NEC and CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Groups F, G Class III Simultaneous Presence (Cl. I and Cl. II) • UL Standards: 844 Hazardous (Classified) Areas 1598 Luminaires • CSA Standards: C22.2 No. 137 53 1/4” 7 1/4” 5 3/4” 15” Ordering Information (Lamps not supplied): Lamp Watts Line Voltage/Hertz Lamp Type 32 32 40 40 40 60 60 60 60 120–277/50–60 347 / 60 120 / 50–60 277 / 60 347 / 60 120 / 60 277 / 60 347 / 60 220 / 50 T8 T8 T12 T12 T12 T12HO T12HO T12HO T12HO Hub Size 2-Lamp Cat. # 3-Lamp Cat. # /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 FVN4232TG/UNV FVN4232TG/347 FVN4240TG/120 FVN4240TG/277 FVN4240TG/347 FVN4260TG/120 FVN4260TG/277 FVN4260TG/347 FVN4260TG/200 50 FVN4332TG/UNV FVN4332TG/347 FVN4340TG/120 FVN4340TG/277 FVN4340TG/347 — — — — FVN4254TG/UNV FVN4254TG/347 — — 1 NPT NPT NPT NPT NPT NPT NPT NPT NPT FVN Fluorescent Luminaires with T5 HO Lamps (Lamps not supplied) 1 54 120–277/50–60 T5HO /2 NPT 1 54 347 / 60 T5HO /2 NPT 1106 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1106-1107.qxp 12/16/2013 6:55 PM Page 1107 FVN Series Fluorescent Luminaires CI. I, Div. 2, Groups A, B, C, D CI. I, Zone 2, Group IIC CI. II, Div. 1, Groups F, G CI. III & Simultaneous Presence 5L Wet Locations NEMA 3, 3R Options: The following special options are available from the factory by adding suffix to luminaire Cat. No.: Description • Low temperature electromagnetic ballast, 40W rated 0°F (-18°C), 60W rated -20°F (-29°C)............................................................. • 45° angle brackets (field installed)........................................................................................................................................................ • Adjustable angle brackets (field installed)............................................................................................................................................ • Angle bars for chain suspension (field installed).................................................................................................................................. • Individually fused ballast (internal)........................................................................................................................................................ • Emergency lighting battery unit (Class I, Division 2 only). Also available for use with T5 lamps. Supplied with charging indicator light and instructions for use with a remote push-to-test station........................................................................................................ Suffix BY AG KH CX FB S799* *If push-to-test operator installed in the luminaire is required, consult factory. Temperature Performance Data: (Based on 40°C ambient) Cl. I, Div. 2 & Zone 2 Lamp 32W 40W 54W 60W 2-Lamp T5 T5 T3C T4 Class II 3-Lamp T5 T5 — — 2-Lamp T6 T6 T6 T6 Simultaneous Presence 3-Lamp T6 T6 — — 2-Lamp T4 T4 T3C/T6 T4 3-Lamp T4 T4 — — Supply Wire 60°C 60°C 75°C 90°C Photometric Data: Luminaire with two 54W High Output T5 Linear Fluorescent Lamps FVN4254 5L FVN .ies photometric files for use with our Luxicon® Lighting Layout Software are available from our website. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1107 1108-1109.qxp 12/16/2013 5L 6:55 PM Page 1108 Photometric Data FVN Series Fluorescent Luminaires Luminaire: FVN with 2-40W lamps (tempered lens) Lamp: Zonal Degrees: Zonal Lumens: Total Bare Lamp Lumens: 2–40/T-12 0–30 1182 6300 Luminaire: FVN with 3–40W lamps (tempered lens) 0–40 0–60 0–90 1971 3555 4284 Lamp: Zonal Degrees: Zonal Lumens: Total Bare Lamp Lumens: 0–40 0–60 0–90 2834 5099 6079 All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass. All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .682 .658 .637 .610 .572 .540 .546 .501 .466 .488 .438 .399 .439 .385 .346 .452 .399 .359 70 50 30 10 .668 .646 .625 .599 .563 .535 .538 .495 .462 .480 .433 .396 .430 .381 .343 .488 .444 .410 .439 .392 .357 50 50 30 10 .640 .622 .606 .576 .547 .521 .520 .454 .433 .464 .423 .391 .418 .374 .341 .528 .496 .468 .473 .435 .405 .426 .384 .353 30 50 30 10 .615 .601 .587 .556 .532 .511 .502 .472 .446 .450 .415 .386 .406 .367 .337 .568 .544 .526 .512 .484 .460 .459 .426 .399 .414 .378 .349 10 50 30 10 .594 .581 .570 .537 .517 .499 .487 .461 .439 .437 .406 .381 .394 .361 .333 .512 .447 .385 .336 0 0 .557 .487 .426 .368 .321 Room Cavity Ratio 6 7 8 9 10 % Reflectance Eff. Ceil. Wall Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .416 .359 .319 .375 .319 .281 .338 .283 .244 .309 .254 .217 .269 .215 .180 80 50 30 10 .396 .343 .305 .357 .304 .268 .322 .270 .234 .294 .242 .207 .256 .205 .172 70 50 30 10 .409 .356 .316 .370 .315 .278 .333 .281 .244 .305 .252 .217 .265 .215 .180 70 50 30 10 .390 .340 .302 .352 .301 .266 .317 .268 .233 .290 .240 .207 .252 .205 .172 50 50 30 10 .397 .350 .314 .359 .309 .276 .324 .277 .242 .297 .249 .215 .259 .211 .179 50 50 30 10 .378 .334 .300 .342 .295 .264 .309 .264 .231 .282 .237 .206 .247 .201 .171 30 50 30 10 .386 .344 .311 .348 .306 .273 .316 .272 .240 .289 .244 .214 .253 .208 .177 30 50 30 10 .368 .328 .298 .332 .292 .261 .301 .259 .230 .276 .233 .204 .241 .199 .169 10 50 30 10 .376 .338 .308 .341 .301 .271 .308 .268 .239 .282 .242 .212 .247 .205 .175 10 50 30 10 .358 .322 .294 .325 .288 .259 .294 .256 .228 .269 .231 .202 .235 .196 .168 0 0 .295 .258 .226 .200 .164 0 0 .283 .247 .217 .192 .157 % Reflectance Eff. Ceil. Wall 5L 3–40/T-12 0–30 1695 9450 Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .721 .695 .673 .643 .603 .569 .575 .527 .489 .513 .459 .418 .461 .404 .362 70 50 30 10 .706 .683 .661 .631 .594 .564 .566 .520 .485 .505 .455 .415 50 50 30 10 .677 .657 .641 .607 .577 .549 .547 .508 .476 30 50 30 10 .650 .636 .621 .586 .561 .538 10 50 30 10 .627 .614 .602 0 0 .589 % Reflectance Eff. Ceil. Wall 1108 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 % Reflectance Eff. Ceil. Wall Copyright© 2013 Eaton’s Crouse-Hinds Business 1108-1109.qxp 12/16/2013 6:55 PM Page 1109 Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 2, Groups F, G Cl. II, Div. 1, Groups E, F, G (Canada) Cl. I, Zone 1, Group IIC Wet Locations ATEX Certified Enclosure Type 4X and IP66 eLLB20 Series Recessed Mount Fluorescent Luminaires Applications: eLLB Series Luminaires are used: • For flush or surface ceiling mounting • In clean room areas where it is important to have smooth, flush surfaces • Where extreme cleanliness is required as in pharmaceutical, chemical, and electronics manufacturing facilities, as well as in paint shops and spray booths • For tough environmental conditions involving corrosives, water, dust, and extreme temperatures • In areas that require lamps to reach full illumination immediately • Indoor and outdoor ordinary or hazardous areas • For wet locations and areas with hose down / wash down requirements Features and Benefits: Certifications and Compliances: • NEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 1, AEx ed IIC Class II, Division 2, Groups F, G UL Listed • CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 1, Ex eds IIC Class II, Division 1, Groups E, F, G cUL Listed • Enclosure: Type 4X IP66 • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires • CSA Standards: C22.2 No. 9 CAN/CSA-E60079-0:02 CAN/CSA-E60079-1:02 CAN/CSA-E60079-7 CAN/CSA-E61241-1-1:02 Adjustable Mounting Clamps ATEX • ATEX Directive 94/9/EC • Type of Protection • EC-Type Examination Certificate Ex II 2 G Ex II 2 D T80°C Ex ed IIC T4 Ex ed ib IIC T4 (CG-variant) DMT 02 ATEX E 069 Standard Materials: • One-piece welded housing and cover frame - sheet steel or stainless steel • Lens – 6mm (1/4") thick tempered glass • Gaskets – silicone • External hardware – stainless steel 5L • One-piece welded housing with fitted cover frame; the cover frame is an integral part of the housing to seal out dust and moisture • Adjustable mounting clamps: Permanently attached and adjustable through the cover frame for easy installation Allow recess mounting in ceilings from 25mm to 100mm (1" to 4" approx.) thick for maximum mounting flexibility • Support lugs (M8 x .6) to secure the luminaire to ceiling structural support members for safety • Frameless tempered glass lens: 6mm (1/4") thick for added safety Interior hinge for maximum dust shedding Fitted with captive screws for ease of lamp replacement and maintenance • Isolating switch turns off power to the ballast and lamps when the lens is opened for added safety • 4 entries (2 on each end) supplied with (2) 3/4" NPT adapter hubs and extra large wire well for feed-through and tandem applications without the need for separate junction boxes • Electronic ballast: High power factor (95%) for energy efficiency, more luminaires per circuit and supply voltage flexibility Features 2 channel circuitry for safety if one lamp fails, the 2nd lamp remains in operation • Uses T8 linear fluorescent lamps for high efficiency and reduced operating costs • 5 wire terminal block and through wiring are standard for quick and easy balancing of lighting loads on 3-phase systems 5L Hinged Glass Lens Standard Finishes: • Sheet steel – white epoxy coat • Lens – clear • Stainless steel – natural www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1109 1110-1111.qxp 5L 12/16/2013 6:55 PM Page 1110 eLLB20 Series Recessed Mount Fluorescent Luminaires Cl. II, Div. 2, Groups F, G Cl. II, Div. 1, Groups E, F, G (Canada) Wet Locations Enclosure Type 4X and IP66 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, Group IIC ATEX Certified Ratings (Electrical / Size): Temperature Performance Data: Sources/Wattages • Two 32W or 17W T8 Linear Fluorescent Voltages • 120–240V, 50–60 Hz • 110–230VDC Hub Size • Four 25mm entries, 2 on each end, 3 plugged • Two 3/4" NPT adapter hubs provided standard, for feed-through or tandem wiring Terminals • 5 wire terminal block, one on each end (L1, L2, L3, N, Ground) • Two 6mm2 (#10 AWG) maximum per terminal Minimum Starting Temperature: -20°C Watts Two 17W T8 lamps Two 32W T8 lamps Ambient Temp. Cl. I, Div. 2 Cl. I, Zone 1 & 2 Class II Supply Wire Temp. 50°C 50°C T4 T4 T6 T6 60°C 60°C Accessories: Description Cat. # • 3/4" NPT adapter hub STM 2 Mounting Accessories: • Eye Bolt for Support Lugs • Hexagon Screw for Support Lugs 2 2480 002 000 2 2480 054 000 Ordering Information: Cat. # Hub Size Wattage/Lamp Voltage/Hz /4" NPT Two 17 Watt T8 Rapid Start 120–240V, 50–60 Hz 110–230 VDC 3 120–240V, 50–60 Hz 110–230 VDC IEC / CENELEC certified luminaries are available. Consult factory. /4" NPT 3 Two 32 Watt T8 Rapid Start Operating Current Epoxy Coated Steel Enclosure Stainless Steel Enclosure .18A ELLB202217/U240 ELLB202217SS/U240 .34A ELLB204232/U240 ELLB204232SS/U240 Dimensions (Inches) and Weights: 5L Item eLLB20 2217 eLLB20 4232 1110 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Weight 33 lbs. 48 lbs. 1110-1111.qxp 12/16/2013 6:55 PM Page 1111 eLLB20 Series 5L Photometric Data Recessed Mount Fluorescent Luminaires Photometric Data: Coefficients Of Utilization – Zonal Cavity Method Effective Floor Cavity Reflectance 20% Room Cavity Ratio 5L Eff. Ceil. Wall 1 2 3 4 5 6 7 8 9 10 80* 50* 30* 10* 0.679 0.654 0.631 0.597 0.556 0.522 0.528 0.478 0.439 0.468 0.414 0.372 0.412 0.355 0.313 0.368 0.310 0.269 0.329 0.272 0.233 0.294 0.239 0.200 0.263 0.209 0.172 0.239 0.186 0.151 70* 50* 30* 10* 0.664 0.641 0.621 0.585 0.547 0.516 0.518 0.472 0.435 0.459 0.409 0.369 0.405 0.351 0.311 0.632 0.307 0.268 0.324 0.270 0.232 0.290 0.237 0.200 0.259 0.207 0.172 0.235 0.185 0.151 50* 50* 30* 10* 0.637 0.618 0.601 0.562 0.531 0.504 0.499 0.460 0.427 0.443 0.399 0.364 0.391 0.344 0.308 0.350 0.302 0.266 0.314 0.265 0.230 0.281 0.233 0.198 0.252 0.204 0.171 0.229 0.182 0.150 30* 50* 30* 10* 0.612 0.597 0.583 0.542 0.515 0.492 0.482 0.448 0.420 0.429 0.390 0.360 0.379 0.337 0.304 0.339 0.296 0.263 0.305 0.261 0.228 0.273 0.229 0.197 0.245 0.201 0.170 0.223 0.180 0.149 10* 50* 30* 10* 0.589 0.577 0.566 0.522 0.501 0.481 0.465 0.437 0.413 0.415 0.382 0.355 0.367 0.330 0.301 0.329 0.291 0.261 0.296 0.257 0.257 0.265 0.226 0.196 0.238 0.198 0.169 0.217 0.177 0.149 0* 0* 0.553 0.468 0.400 0.341 0.288 0.248 0.214 0.183 0.156 0.137 *Percent Reflectance. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1111 1112-1113.qxp 12/16/2013 6:55 PM Page 1112 Paint Spray (Suffix S718) Wet Locations (Suffix S718) 3, 3R, IP54 (Suffix S718) Cl. I, Div. 1, Groups C, D Cl. I, Zone 1, Group IIB Cl. II, Div. 1, Groups E, F, G Cl. III, Simultaneous Presence EVF Series Fluorescent Luminaires 5L Applications: • EVF Luminaires are used in areas where hazardous fumes, gases, or dusts are present • EVF Luminaires with S718 option are designed specifically for use inside paint spray booths where hazardous fumes, gases, and paint residue are present; this includes powder paint process areas • EVF Luminaires with S718 option are also suitable for use in wet locations Furnished For Use with 5L All EVF Luminaires: • Provide cool, even light with natural color rendition • Reduce relamping schedule (long lamp life) • Continuous and uniform illumination made possible by mounting end to end (no space needed between luminaires for relamping) • No special tools required for relamping; threaded lamp tube cover provides quick and easy access for relamping • Threaded joints on lamp tube and wiring chamber covers permit easy access for lower maintenance costs • Reflectors can be removed or replaced with only a screwdriver • Easy to install; factory-sealed and wired luminaire facilitates installation • Standard electronic ballast for 32 watt and 40 watt rapid start luminaires • Standard energy-efficient ballast for 40 watt slimline, 60 watt and 110 watt luminaires • Low temperature ballast is supplied as standard on 32 watt T8 (0°F), 40 watt slimline (0°F), 60 watt and 110 watt luminaires (-20°F) • All exposed hardware is stainless steel for maximum protection against corrosion, and for longer luminaire life • Copper-free aluminum construction throughout means lighter luminaire weight, easier installation, and excellent corrosion resistance • All exterior materials are non-sparking • Type P ballasts furnished in compliance with NEC • Heavy-duty glass lamp tubes provide maximum strength and impact resistance to protect lamps EVF Luminaires with S718 Option: • All joints sealed • Inside paint booth mounting capabilities provide greater flexibility in luminaire placement, avoids necessity of complicated design and installation work, and improves task lighting control • Smooth, simple design makes it easy to remove any accumulated deposits of paint residue www.crouse-hinds.com 2-lamp with angle reflector Ordering Information: Features: 1112 3-lamp Hub Line Volts 1-Lamp Size 60 Hz Cat. # 2-Lamp Cat. # 3-Lamp Cat. # 4-Lamp Cat. # 32 watt, T-8 medium 3/4" Bi-pin 265MA lamps 3/4" 120–277 347 EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV EVF21029/347 EVF22029/347 EVF23029/347 EVF24029/347 40 watt, T-12 medium 3/4" 3 Bi-pin rapid start /4" 3 430MA lamps† /4" 110–125 277 347 EVF21082 EVF22082 EVF23082 EVF24082 EVF21087 EVF22087 EVF23087 EVF24087 EVF21089/347 EVF22089/347 EVF23089/347 EVF24089/347 /4" /4" /4" 110–125 277 347 EVF21032 EVF22032 EVF23032 EVF24032 EVF21037 EVF22037 EVF23037 EVF24037 EVF21039/347 EVF22039/347 EVF23039/347 EVF24039/347 3 /4" /4" 3 /4" 110–125 277 347 EVF21062 EVF22062 EVF23062 EVF24062 EVF21067 EVF22067 EVF23067 EVF24067 EVF21069/347 EVF22069/347 EVF23069/347 EVF24069/347 /4" /4" 3 /4" 110–125 277 347 EVF21072 EVF22072 EVF23072 EVF24072 EVF21077 EVF22077 EVF23077 EVF24077 EVF21079/347 EVF22079/347 EVF23079/347 EVF24079/347 40 watt, T-12 single pin, slimline 425MA lamps 3 60 watt, T-12 recessed contact, 800MA lamps† 3 110 watt, T-12 recessed contact, 1500MA lamps† 3 3 3 3 †50 Hz not available. Certifications and Compliances: Options: Description Suffix • For suitability for wet • NEC and CEC: locations and locations Class I, Division 1, Groups C, D having deposits of Class I, Zone 1, Group IIB readily combustible Class II, Groups E, F, G paint residue ................... Class III • Corro-free™ epoxy Simultaneous Presence (Cl. I powder coat.................... • With 45° angle reflectors and Cl. II) in lieu of straight down Paint Spray (S718) reflectors ......................... • UL Standards: • Fused (not suitable for 844 Hazardous (Classified) marine applications)........ Locations • Furnished with lamps...... 1598 Luminaires • Low temperature • CSA Standards: electromagnetic ballast C22.2 No. 137 for 40 watt T12 rapid start luminaires rated for 0°F ............................. • Copper-free aluminum except sheet aluminum reflectors Standard Materials: S718 S752 S369 S658 S714 US: 1-866-764-5454 Various hazardous area fittings are used to mount EVF Luminaires. The fittings shown on next page support the unwired (relamping) end. For the wired (ballast) end any of the luminaire hangers for hazardous locations (listed in Section 7L) can be used. CPS conduit outlet bodies with hub covers (listed in Section 3F) are also suitable. Size Ranges: BY • 1, 2, 3, and 4-lamp Electrical Rating Ranges: Standard Finishes: • Natural except reflectors • Reflectors – white epoxy powder coat Mounting Accessories: • 32 to 110 watts Temperature Performance Data: (Based on 40°C Ambient) Class I/Class II/Zone 1 Lamp Type 1-Lamp 2-Lamp 3-Lamp 4-Lamp Supply Wire 32/40W 60W 110W CAN: 1-800-265-0502 T5 T5 T4 T5 T5 T4 Copyright© 2013 Eaton’s Crouse-Hinds Business T5 T5 T4 T5 T5 T4 75°C 75°C 90°C 1112-1113.qxp 12/16/2013 6:55 PM Page 1113 Accessories Relamping Information EVF Series Fluorescent Luminaires Ceiling Saddle 5L Relamping Information Conduit Support Size (In.) Cat. # Description Ceiling Saddle for Conduit Support /4 3 EVF20 Ceiling Saddle Support Hook Adjacent ends of two fixtures suspended in line close together Description Cat. # Ceiling Saddle for Support Hook EVF021 One cover removed and lamp partly withdrawn Where fixtures abut, space for relamping is obtained by lowering one end of the tube assembly as shown. Without tools, the lamp receptacle and mounting plate assemblies can be removed and the lamp withdrawn. In inserting, the reverse procedure is followed. Support Hook for Conduit Description Support Hook for Conduit Size (In.) Cat. # /4 EVF21 3 End of one fixture lowered for relamping Dimensions: 5L End view Fixture Type 32 watt, T-8 Bi-pin 40 watt, T-12 Bi-pin 40 watt, T-12 Single pin slimline 60 watt, T-12 Recessed contact 110 watt, T-12 Recessed contact No. Lamps 1 or 2 3 or 4 www.crouse-hinds.com a b 44 11 461/2 81/2 c d 533/8 55 533/8 55 US: 1-866-764-5454 e f 95 101/4 100 101/4 CAN: 1-800-265-0502 No. of Lamps 1-Lamp 2-Lamp 3-Lamp 4-Lamp Width 61/8 111/2 18 241/2 Copyright© 2013 Eaton’s Crouse-Hinds Business 1113 1114-1115.qxp 12/16/2013 6:56 PM Page 1114 Luminaire: All 1-Lamp EVF Luminaires Lamp: Zonal Degrees: Zonal Lumens: Total Bare Lamp Lumens: 1-40/T-12, 1-60/T-12 0–30 0–40 580 953 3100 Luminaire: All 2-Lamp EVF Luminaires 0–60 0–90 1633 1897 2-40/T-12, 2-38/T-12, 2-60/T-12, 2-110/T12 Lamp: 0–30 0–40 0–60 0–90 Zonal Degrees: 1055 1765 3262 4125 Zonal Lumens: Total Bare Lamp Lumens: 6300 All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 Example: Zonal lumens of 1–40W lamp for 0–60° is 1633. Zonal lumens of 1–60W lamp for 0–60 is 1633 x 1.29 = 2107 Example: Zonal lumens of 2–40W lamp for 0–60° is 3262. Zonal lumens of 2–60W lamps for 0–60 is 3262 x 1.29 = 4208 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 5L Photometric Data EVF Series Fluorescent Luminaires 5L Room Cavity Ratio 1 2 3 4 5 % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .697 .670 .647 .616 .574 .539 .546 .497 .458 .485 .430 .388 .434 .376 .334 80 50 30 10 .697 .670 .647 .616 .574 .539 .546 .497 .458 .485 .430 .388 .434 .376 .334 70 50 30 10 .682 .658 .635 .604 .565 .534 .538 .490 .454 .477 .426 .385 .425 .372 .331 70 50 30 10 .682 .658 .635 .604 .565 .534 .538 .490 .454 .477 .426 .385 .425 .372 .331 50 50 30 10 .653 .633 .616 .580 .549 .520 .518 .478 .446 .460 .416 .380 .412 .365 .329 50 50 30 10 .653 .633 .616 .580 .549 .520 .518 .478 .446 .460 .416 .380 .412 .365 .329 30 50 30 10 .627 .612 .597 .559 .533 .509 .500 .467 .438 .445 .407 .375 .399 .357 .325 30 50 30 10 .627 .612 .597 .559 .533 .509 .500 .467 .438 .445 .407 .375 .399 .357 .325 10 50 30 10 .605 .591 .579 .539 .517 .498 .484 .455 .431 .431 .397 .370 .388 .351 .321 10 50 30 10 .605 .591 .579 .539 .517 .498 .484 .455 .431 .431 .397 .370 .388 .351 .321 Room Cavity Ratio 6 7 8 9 10 .391 .334 .294 .351 .295 .257 .316 .262 .223 .289 .235 .197 .252 .198 .164 % Reflectance Eff. Ceil. Wall % Reflectance Eff. Ceil. Wall 9 10 80 50 30 10 Room Cavity Ratio 6 7 8 .316 .391 .351 .334 .295 .262 .294 .257 .223 .289 .235 .197 .252 .198 .164 80 50 30 10 70 50 30 10 .384 .330 .290 .346 .292 .255 .312 .260 .222 .285 .233 .197 .248 .198 .164 70 50 30 10 .384 .330 .290 .346 .292 .255 .312 .260 .222 .285 .233 .197 .248 .198 .164 50 50 30 10 .372 .324 .288 .336 .286 .252 .303 .255 .221 .277 .229 .196 .242 .195 .162 50 50 30 10 .372 .324 .288 .336 .286 .252 .303 .255 .221 .277 .229 .196 .242 .195 .162 30 50 30 10 .361 .319 .286 .325 .283 .249 .295 .251 .219 .270 .225 .194 .236 .192 .161 30 50 30 10 .361 .319 .286 .325 .283 .249 .295 .251 .219 .270 .225 .194 .236 .192 .161 10 50 30 10 .351 .312 .283 .318 .278 .248 .287 .247 .218 .263 .222 .193 .230 .189 .159 10 50 30 10 .351 .312 .283 .318 .278 .248 .287 .247 .218 .263 .222 .193 .230 .189 .159 1114 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1114-1115.qxp 12/16/2013 6:56 PM Page 1115 EVF Series Fluorescent Luminaires Luminaire: All 4-Lamp EVF Luminaires Luminaire: All 3-Lamp EVF Luminaires Lamp: Zonal Degrees: Zonal Lumens: Total Bare Lamp Lumens: 5L Photometric Data 3-40/T-12, 3-38/T-12, 3-60/T-12, 3-110/T-12 0–30 0–40 0–60 0–90 1917 3226 6066 7919 9300 4-40/T-12, 4-38/T-12, 4-60/T-12, 4-110/T-12 Lamp: 0–30 0–40 0–60 0–90 Zonal Degrees: 1961 3305 6250 8224 Zonal Lumens: Total Bare Lamp Lumens: 12400 All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 Example: Zonal lumens of 3–40W lamps for 0–40° is 3226. Zonal lumens of 3–40W Slimline lamps for 0–40° is 3226 x 0.84 = 2710 Example: Zonal lumens of 4–40W lamps for 0–30° is 1961. Zonal lumens of 4–110W Slimline lamps for 0–30° is 1961 x 2.19 = 4295 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 4 5 80 50 30 10 .712 .683 .658 .626 .581 .544 .553 .500 .459 .489 .431 .386 .436 .376 .331 70 50 30 10 .697 .670 .646 .614 .572 .539 .544 .494 .455 .481 .426 .383 50 50 30 10 .667 .645 .626 .589 .555 .524 .524 .481 .446 30 50 30 10 .640 .623 .607 .567 .539 .513 10 50 30 10 .617 .602 .589 .547 .523 .502 Room Cavity Ratio 1 2 3 4 5 80 50 30 10 .692 .664 .639 .607 .563 .526 .535 .484 .442 .473 .416 .372 .421 .362 .318 .427 .371 .328 70 50 30 10 .678 .652 .628 .595 .554 .521 .526 .477 .439 .465 .411 .369 .412 .357 .315 .463 .416 .378 .414 .364 .326 50 50 30 10 .648 .627 .609 .571 .538 .507 .507 .465 .431 .447 .401 .364 .399 .351 .313 .505 .469 .439 .447 .407 .374 .400 .356 .322 30 50 30 10 .622 .606 .590 .550 .522 .497 .488 .453 .423 .432 .392 .360 .386 .343 .309 .488 .457 .431 .433 .397 .368 .388 .350 .318 10 50 30 10 .600 .585 .572 .530 .506 .486 .472 .442 .416 .418 .383 .354 .374 .337 .305 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .392 .332 .290 .352 .293 .254 .317 .260 .219 .289 .233 .194 .252 .196 .160 70 50 30 10 .385 .329 .287 .347 .290 .251 .312 .258 .218 .285 .230 .194 50 50 30 10 .372 .322 .285 .336 .284 .248 .303 .253 .217 30 50 30 10 .362 .317 .282 .325 .280 .245 10 50 30 10 .351 .310 .279 .317 .276 .244 % Reflectance Eff. Ceil. Wall % Reflectance Eff. Ceil. Wall Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .379 .320 .278 .340 .282 .243 .306 .250 .210 .279 .224 .185 .243 .189 .153 .248 .196 .160 70 50 30 10 .372 .316 .275 .335 .279 .240 .301 .248 .209 .275 .221 .185 .239 .189 .153 .277 .227 .192 .242 .193 .159 50 50 30 10 .359 .310 .273 .324 .273 .238 .292 .243 .208 .267 .218 .184 .233 .185 .152 .295 .248 .215 .269 .223 .191 .236 .190 .157 30 50 30 10 .349 .305 .271 .313 .269 .235 .284 .238 .206 .260 .214 .183 .227 .182 .150 .286 .244 .214 .262 .220 .189 .230 .187 .156 10 50 30 10 .339 .298 .268 .306 .265 .234 .276 .235 .205 .253 .211 .181 .221 .179 .149 www.crouse-hinds.com US: 1-866-764-5454 % Reflectance Eff. Ceil. Wall CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1115 5L Room Cavity Ratio 1 2 3 1116-1117.qxp 12/23/2013 5L 3:15 PM Page 1116 EVFDR Series Fluorescent Luminaires Marine & Wet Locations 3, 3R, 4, 4X; IP66 Cl. I, Div. 1, Groups C, D Cl. I, Zone 1, Group IIB Cl. II, Div. 1, Groups E, F, G Cl. III, Simultaneous Presence Applications: • EVFDR Luminaires are suitable for wet locations and marine environments, above and below deck, where hazardous vapors, gases or dusts are present • Ideally suited for use on offshore drilling/production platforms and on shipboard in hazardous areas • For mounting where headroom is limited • For hazardous areas where watertightness and corrosion resistance are required 5L Features: • Exterior surfaces finished with gray epoxy enamel for corrosion resistance • Exterior hardware stainless steel • All joints sealed and gasketed for watertightness • Vibration resistant – Shock mounts – Sockets are spring loaded for tight lamp contact connection • Heavy duty glass lamp tubes for maximum strength and impact resistance • All exterior materials are non-sparking • C-type beam clamps provide quick and easy mounting • Luminaire is adjustable 30° either side of fixture axis, allowing for control of light output • Beam clamp support is adjustable allowing beam clamp to be located to suit structure • Low profile – luminaire height is 713/16" with standard mounting, 1111/16" with shock mounting option – for maximum clearance where headroom is critical • Provides cool light with natural color rendition • Continuous and uniform illumination made possible by mounting end to end (no space needed between luminaires for relamping) – see page 1113 for relamping information • Relamping is accomplished without tools; quarter-turn fastener allows end of luminaire to be lowered quickly; cable supports end of luminaire while relamping – both hands are free; threaded lamp tube cover provides quick and easy access to lamp and receptacle • Reflectors can be removed or replaced with only a screwdriver • Ballast housing readily accessible • Minimum weight – copper-free aluminum construction throughout • Type P ballast furnished in compliance with NEC • Standard electronic ballast for 32 watt and 40 watt rapid start 1116 www.crouse-hinds.com US: 1-866-764-5454 • Standard energy-efficient electromagnetic ballast (40W slimline, 60W and 110W) is standard • Low temperature ballasts are standard on 32W T8, 40W slimline, 60W and 110W; 32 watt and 40 watt low temperature ballasts are rated for 0°F; 60 and 100 watt low temperature ballasts are rated for -20°F Certifications and Compliances: • NEC and CEC: Class I, Division 1, Groups C, D Class I, Zone 1, Group IIB Class II, Groups E, F, G Class III Simultaneous Presence (Cl. and Cl. II) • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 Standard Materials: Options: Description Suffix • Furnished with lamps.................... S714 • Furnished with safety cable for high vibration areas................. S715 • Beam clamps with shock mounts are available for ease of installation and resistance to vibration.................................... KIT40 • Beam clamps only........................ KIT41 • Low temperature electromagnetic ballast: 40W rapid start rated 0°F...................... BY • Emergency lighting battery unit.... S799 Size Ranges: • 2–lamp only Electrical Rating Ranges: • 32, 40, 60 and 110W Temperature Performance Data: (Based on 40°C Ambient) 2-Lamp 32, 40W 60W 110W • Housing – copper-free aluminum • Exposed hardware – stainless steel Class I Class II Zone 1 Supply Wire T5 T5 T4 75°C 75°C 90°C Standard Finishes: • All exterior metal components – gray epoxy enamel • Reflectors – white epoxy powder coat Ordering Information: Furnished For Use With Hub Size Line Volts 60 Hz. 2-Lamp Cat. # 32 watt, T-8 medium Bi-pin 265MA lamps 3 /4" /4" 120–277 347 EVFDR22029/UNV EVFDR22029/347 40 watt, T-12 medium Bi-pin rapid start 430MA lamps† 3 /4" /4" 110–125 277 EVFDR22082 EVFDR22087 60 watt, T-12 recessed contact, 800MA lamps 110 watt, T-12 recessed contact, 1500MA lamps† 3 /4" /4" 110–125 277 EVFDR22062 EVFDR22067 /4" /4" 110–125 277 EVFDR22072 EVFDR22077 3 3 3 3 3 †50 Hz not available. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1116-1117.qxp 12/23/2013 3:15 PM Page 1117 Photometric Data and Dimensions EVFDR Series Fluorescent Luminaires Luminaire: All EVFDR Luminaires Lamp: Zonal Degrees: Zonal Lumens: Total Bare Lamp Lumens: 5L Dimensions: 2-40/T-12, 2-60/T-12, 2-110/T-12 0–30 0–40 0–60 0–90 1416 2352 4263 5863 8600 All data provided is for two 60 watt, T-12 recessed contact 800MA cool white lamps (EVFDR22062). For other wattages use the following conversion factors: 32W 40W, Rapid Start 40W, Slimline 110W, Cool White .67 .73 .70 1.60 Example: Zonal lumens for EVFDR226 fixture, across the axis, for 40–50" is 1,060. Zonal lumens for EVFDR223 fixture, across the axis, is 40–50" is: 1,060 x .70 = 742 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 4 5 80 50 30 10 .735 .700 .670 .645 .594 .551 .570 .512 .466 .506 .442 .394 .452 .387 .339 70 50 30 10 .714 .682 .653 .627 .580 .542 .557 .501 .458 .494 .435 .388 .440 .380 .334 50 50 30 10 .673 .647 .624 .593 .554 .520 .528 .482 .444 .468 .418 .378 .420 .368 .327 30 50 30 10 .636 .616 .596 .562 .530 .502 .501 .463 .430 .446 .403 .368 .401 .354 .319 10 50 30 10 .603 .585 .570 .533 .507 .483 .477 .444 .416 .425 .388 .358 .383 .343 .311 0 0 .551 .465 .399 .340 .294 Room Cavity Ratio 6 7 8 9 10 80 50 30 10 .408 .344 .298 .368 .305 .262 .332 .271 .228 .304 .243 .202 .266 .207 .169 70 50 30 10 .398 .338 .293 .360 .299 .258 .325 .267 .226 .297 .240 .201 .260 .206 .168 50 50 30 10 .380 .327 .287 .344 .289 .252 .311 .259 .221 .285 .233 .197 .250 .199 .164 30 50 30 10 .364 .317 .281 .328 .282 .246 .299 .251 .217 .274 .226 .193 .240 .193 .160 10 50 30 10 .348 .306 .274 .316 .274 .241 .286 .244 .213 .263 .220 .189 .231 .188 .157 0 0 .259 .226 .198 .175 .144 % Reflectance Eff. Ceil. Wall www.crouse-hinds.com US: 1-866-764-5454 5L Room Cavity Ratio 1 2 3 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1117 1118-1119.qxp 12/16/2013 6:56 PM Page 1118 5L 5L 1118 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1118-1119.qxp 12/16/2013 6:56 PM Page 1119 6L Champ-Pak™ Wall Pack & Floodlight Luminaires Hazardous and Non-hazardous Description Page No. Application/Selection see page 1120 Floodlights Champ-Pak™ CPMV see page 1121 H.I.D. FMV nR Series FMV1000 nR High Wattage Series Voyager nR™ Stainless Steel Series F2MV Mini Floodlight Series FZD Series EVMA S812 Hazard•Gard with Trunnion Arm see see see see see pages 1135–1138 pages 1139–1141 pages 1142–1145 pages 1150–1153 pages 1154–1156 see page 1157 Incandescent RCDE Series see pages 1158–1159 LED Champ® Pro PFM Series Champ® Pro PFM25L and 50L Series Champ® FMV Series see pages 1128–1129 see pages 1130–1132 see pages 1146–1149 6L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1119 1120-1121.qxp 12/16/2013 6L 6:56 PM Page 1120 Champ-Pak™ Wall Pack & Floodlight Luminaires Applications: Considerations for Selection: • General illumination of hazardous and non-hazardous areas Environmental: • What is the hazardous area classification NEC®/CEC) of the location in which the luminaires will be installed? Lighting levels required: • What wattage luminaire(s) will provide the desired light levels? Physical arrangement: • Type of luminaire mounting required, threaded hub or mounting feet Table 500.8(C) Identification Numbers Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Application and Selection Quick Selector Chart Temperature Class (T Code) T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Quick Selector Chart NEC Hazardous Area Compliance Lamp Size (Watts) Lamp Base CPMV Cl. I, Division 2 50–150 HID Mogul EVMA-S812 Cl. I, Groups C, D Cl. I, Groups B (suffix GB), C, D 50–400 HID Mogul VOYAGER nR (SSFMV) Cl. I, Division 2 Cl. I, Zone 2 150–400 HID Mogul 6L Luminaire F2MV, FMV, FMV High Wattage Cl. I, Division 2 70–1500 HID Mogul FZD Cl. I, Division 1, Groups B, C, D 150–400 HID Mogul RCDE-6 Cl. I, Groups C, D Cl. I, Group D 150 Incandescent 300 Incandescent Medium RCDE-10 Cl. I, Group D 500 Incandescent Extended Mogul End Prong PFM Non-hazardous areas 64–179 LED PFM25L/PFM50L Non-hazardous areas 263–531 LED FMV Cl. Cl. Cl. Cl. 64–179 LED 1120 www.crouse-hinds.com I, Division 2, Groups A, B, C, D I, Zone 2 II, Groups E, F, G III US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1120-1121.qxp 12/16/2013 6:56 PM Page 1121 Champ-Pak™ Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations Enclosure Type 4X, IP66 6L The first low-profile wall pack designed specifically for hazardous areas. The Eaton's Crouse-Hinds Champ-Pak™ Wall Pack Luminaire is ideal for low-profile mounting in hazardous and industrial environments. In fact, it is suitable for any area with adverse conditions such as dust, dirt, moisture, vibration, high-pressure hose downs, and high thermal ambients. Its precisely designed glass refractor minimizes fixture depth while providing uniform, glare-free illumination. • Unique compact shallow-profile design mounts virtually anywhere • Side-hinged cover with two-screw closing for easy installation and maintenance • Gray Corro-free™ epoxy powder coated two-piece housing provides superior corrosion resistance • Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance • Glass refractor provides uniform light distribution to eliminate glare • Vertical lamp design provides even lamp heat distribution for cooler operation, providing expanded hazardous area suitability • Silicone gaskets make luminaire suitable for enclosure Type 4X, marine, and IP66 environments • Available in two different conduit entry configurations to permit flexible installation and mounting • Four 3/4" NPT hubs, one on each side • Two 1/2" NPT hubs on bottom for feed-through applications Additional Features and Benefits: • Indoor and outdoor wall mounting or vertical surface mounting where minimal fixture depth is required in: • Manufacturing plants and heavy industrial facilities • Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical, and production platforms • Waste or sewage treatment plants • Offshore, dockside, and harbor installations • For security and safety lighting in industrial facilities • For lighting of loading docks, tunnels, and stairways • For marine, wet location, hose down, and corrosive environments • Variety of lamp types and wattages–HID, fluorescent, and induction–to meet specific lighting needs • High power-factor ballasts (+90%) are standard, which allow more luminaires per circuit • Up to 65°C ambient suitability on select lamp types and wattages; ambient suitability of +40°C is standard; allows for installation in higher ambient environments commonly found in industrial facilities • Low ambient starting capability (to -40°C) – perfect for colder climates • Shock-absorbing HID mogul base lamp socket cushions lamp, improves lamp life in harsh environments www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 6L Applications: • Compact fluorescent emergency luminaire provides 90 minutes of lighting during power outages, meeting UL924 and Life Safety Code • Cost-effective induction lamp system provides extra long lamp life up to 100,000 hours; reaches full illumination immediately, providing crisp, white light • NEC/CEC restricted breathing construction is available to provide cooler temperature classes (T codes) for expanded hazardous area suitability • Simplified method for compliance to NEC restricted breathing conduit sealing requirements makes installation easier Copyright© 2013 Eaton’s Crouse-Hinds Business 1121 1122-1123.qxp 6L 12/16/2013 6:56 PM Page 1122 Champ-Pak™ Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations Enclosure Type 4X, IP66 Certifications and Compliances: Ratings (Electrical/Size): • Luminaires For Use With ANSI Lamps (Mogul Base): UL/cUL Listed NEC and CEC Class I, Division 2 and Class I, Zone 2 Restricted Breathing Class I, Division 2 and Zone 2 (suffix S826) Class II, Groups F, G Class III Simultaneous Presence Certified for IEC Zone 2 (suffix S826TB) Wet Locations; Marine Locations; Enclosure Type 4X; IP66 • UL Standards: 844 – Hazardous (Divisions Classified) Locations 1598 – Luminaires 1598A – Luminaires for Marine Vessels 924 – Emergency Lighting (Fluorescent Emergency Luminaire) • CSA Standards: C22.2 No. 9 and 137 CAN/CSA-E60079-15:02 • IEC Standards: 60079-15 Sources/Wattages • • • • • Voltages Standard Materials: • • • • • • Fixture housing and door frame assembly – copper-free aluminum External hardware – stainless steel Refractor lens – borosilicate glass Gasket – silicone Reflector – aluminum light sheet Wire guard – stainless steel Standard Finishes: 6L • Aluminum – Corro-free™ epoxy powder coat • Stainless steel – natural High-pressure sodium (HPS) – mogul base 50, 70, 100 & 150 Metal halide (MH) – mogul base 70, 100 & 150 Compact fluorescent 26, 32, 42, 52, 64 & 84 Emergency fluorescent 26 Induction 55 & 85 HID Standard-Voltage Ballasts • Dual tap (120 & 277 V, 60 Hz–for 50 W HPS only)–prewired at 277 V • Multi-tap (120, 208, 240 & 277 V, 60 Hz)–prewired at 277 V • Tri-tap (120, 277 & 347 V, 60 Hz)–prewired at 347 V • 120 V, 60 Hz • 480 V, 60 Hz Fluorescent Standard Voltage Ballasts • 120–277 V, 50–60 Hz • 120 V, 50 Hz (for Canada only) • 347 V, 60 Hz (for Canada only) Induction Standard Voltage Ballasts • 120 V, 50–60 Hz (also 120 V DC) • 230 V, 50–60 Hz (also 240 V DC) HID Optional Voltage Ballasts • 220 V, 50 Hz • 220 V, 60 Hz • 240 V, 50 Hz Fluorescent Optional Voltage Ballasts (Consult Factory) • 125 V DC • 12 V DC • 24 V DC Isolated Ballasts And Specials (Consult Factory) • 208 V, 60 Hz CWI Isolated Ballast • 240 V, 60 Hz CWI Isolated Ballast • 480 V, 60 Hz CWI Isolated Ballast Conduit Entries • Four 3/4" NPT entries, one on each side, top and bottom (3 plugged) • Two 1/2" NPT entries on bottom for feed-through (1 plugged) • Metric entries – consult factory 1122 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1122-1123.qxp 12/16/2013 6:56 PM Page 1123 Champ-Pak™ Wall Pack Luminares Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Lamp Watts Cat. # Hub Size Lamp Watts Cat. # Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 26 (one 26 W lamp) CPMVF2W026 CPMVF1W026 Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 32 (one 32 W lamp) CPMVF2W032 CPMVF1W032 Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 42 (one 42 W lamp) CPMVF2W042 CPMVF1W042 Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) CPMVF2W052 52 (two 26 W lamps) CPMVF1W052 Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) CPMVF2W064 64 (two 32 W lamps) CPMVF1W064 84 (two 42 W lamps) 50 CPMVS2W050 CPMVS1W050 70 CPMVS2W070 CPMVS1W070 Four /4" NPT (one each side) Two 1/2" NPT (on bottom) 100 CPMVS2W100 CPMVS1W100 Four /4" NPT (one each side) Two 1/2" NPT (on bottom) CPMVS2W150 150 (for 55 V lamp) CPMVS1W150 Metal Halide Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 70 CPMVM2W070 CPMVM1W070 Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 100 CPMVM2W100 CPMVM1W100 Voltage Suffixes: 150 CPMVM2W150 S828 CPMVM1W150 S828 Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 3 3 Metal Halide–Pulse Start Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) To complete Catalog Number, add Voltage and Option suffix(es). Voltage Suffixes: Voltage (60 Hz) Suffix Voltage (60 Hz) Suffix Dual Tap /DT Dual Tap /DT 6L Ordering Information Fluorescent Luminaires: Ordering Information HID Luminaires: Hub Size High-Pressure Sodium Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations Enclosure Type 4X, IP66 NEC/UL Multi Tap /MT 120 /120 480 /480 CEC (CSA/cUL) Tri Tap 120 /TT /120 NEC/CEC (UL, CSA, cUL) 120–277 V (50–60 Hz) /UNV Voltage Suffix CPMVF2W084 CPMVF1W084 CEC (CSA, cUL) 347 V (60 Hz) /347 Ordering Information Fluorescent Emergency Luminaires – Continuous Operation: Lamp Watts Hub Size Cat. # CPMVFB2W026 Four /4" NPT (one each side) 26 (one 26 W lamp) Two 1/2" NPT (on bottom) CPMVFB1W026 3 50W HPS is available only with suffix /DT. Voltage Suffixes: Voltage Suffix Lamp Watts Cat. # Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 55 CPMVIG2W055 CPMVIG1W055 Four 3/4" NPT (one each side) Two 1/2" NPT (on bottom) 85 CPMVIG2W085 CPMVIG1W085 Hub Size Voltage Suffixes: Voltage 120 V (also 120 V DC) (50–60 Hz) 230 V (also 240 V DC) (50–60 Hz) Suffix /120 /230 www.crouse-hinds.com US: 1-866-764-5454 NEC/CEC (UL, CSA, cUL) 120–277 V (50–60 Hz) /UNV CEC (CSA, cUL) 120 V 347 V (60 Hz) (60 Hz) /120 CAN /347 Compelling reasons to choose the Champ induction luminaire as the light source for industrial and hazardous locations include: • Crisp, white light (80+ color rendering index) provides increased safety by clearly illuminating signs, instrument panels, equipment, and more with vibrant natural colors • Up to 100,000 hours of lamp life minimizes routine maintenance costs; if you operate this luminaire for 24 hours, 7 days a week, you will not need to change the lamp for up to 11 years! • Instant illumination – no waiting for lamp warm-up time; increases productivity and safety • Delivers the best possible luminaire temperature rating – T6 (85°C) when used with the Champ restricted breathing option; ideal for hazardous areas where a low ignition temperature is required • Starts in low temperatures – as low as -40°C CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1123 6L Ordering Information Induction Luminaires With Lamp (100,000 hours): 1124-1125.qxp 12/16/2013 6L 6L 6:56 PM Page 1124 Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Champ-Pak™ Wall Pack Luminares Options: Accessories: Description Suffix Ballast-Gard™ starter cut-out switch ...................................... BG • Not available with IR or QTZ options Factory Assembled with Lamp Installed.................................. FA Instant Restrike .......................................................................... IR • Not available with BG or QTZ options Guard—Factory Installed on Luminaire ................................... P (Guard suffix follows wattage designation, e.g., CPMVS2W100P/MT) Quartz Auxiliary .......................................................................... QTZ Fused ........................................................................................... S658* • Not available with CPMVIG and CPMVFB luminaires • Not suitable for marine applications Restricted Breathing Construction (AEx nR, Ex nR)............... S826 (Order Separately) Description Photocell For Field Installation • 120 V, 50–60 Hz • 208–240 V, 50–60 Hz • 277 V, 50–60 Hz In Canada, use factory-installed photocell only. Stainless Steel Wire Guard Certified For IEC Zone 2 (Ex nR) (UL Classified to the IEC Standard) ....................................................................... S826TB Furnished with: • 4 mm2, 3-point terminal block • Crimp internal wiring connections • P55 guard V2PC Photocell—Factory Installed • 120 V, 50–60 Hz................................................................. /V2PC20 • 208–240 V, 50–60 Hz ......................................................... /V2PC22 • 277 V, 50–60 Hz................................................................. /V2PC27 Optional Voltage Ballasts for HID Luminaires • 220 V, 50 Hz....................................................................... /220 50 • 220 V, 60 Hz....................................................................... /220 60 • 240 V, 50 Hz....................................................................... /240 50 Optional Voltage Ballasts for Fluorescent Luminaires (Consult Factory) • 125 V DC............................................................................ /125 VDC • 12 V DC.............................................................................. /12 VDC • 24 V DC.............................................................................. /24 VDC Isolated Ballast for HID Luminaires (Consult Factory) • 208 V, 60 Hz....................................................................... /208CWI • 240 V, 60 Hz....................................................................... /240CWI • 480 V, 60 H ........................................................................ /480CWI *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. TEFLON is a registered trademark of E.I. duPont Co. Dimensions (In Inches): Note: Approximate weight less guard 28 lbs. P55 guard 0.5 lbs. 1124 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Cl. II, Groups F, G Cl. III & Simultaneous Presence Marine & Wet Locations; Enclosure Type 4X, IP66 Copyright© 2013 Eaton’s Crouse-Hinds Business Cat. # V2PC20 V2PC22 V2PC27 P55 1124-1125.qxp 12/16/2013 6:57 PM Page 1125 Champ-Pak™ Wall Pack Luminares Photometric Data 6L CPMV Photometric Data Luminaire With Refractor Less Wire Guard CPMVS2W150 Lamp: 150 W/E23-1/2 Clear High Pressure Sodium (HPS) Luminaire With Refractor Less Wire Guard CPMVM2W150-S828 Lamp: 150 W/ED28 Clear Pulse Start Metal Halide 6L For additional photometric data, contact Eaton's Crouse-Hinds. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1125 1126-1127.qxp 6L 12/16/2013 6:57 PM Page 1126 Champ-Pak™ Wall Pack Luminares Photometric Data Luminaire With Refractor Less Wire Guard CPMVF2W084 Lamps: (2) PL-T 42W/30/4P Compact Fluorescent 6L For additional photometric data, contact Eaton's Crouse-Hinds. 1126 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1126-1127.qxp 12/16/2013 6:57 PM Page 1127 6L Temperature Performance Data Champ-Pak™ Wall Pack Luminares Temperature Performance Data: Simultaneous Presence Class I/Class II (Gas and Dust Present in the Same Area) Class I Division 2 and Zone 2 Ambient Temp.°C Watts Standard Product HIGH PRESSURE SODIUM 40 T3A 55 T3A 50 65* T3 Restricted Breathing AEx nR/Ex nR Option S826 Suitable for Class I, Division 2 or Zone 2 and Class II Supply Wire Temp.°C Restricted Breathing AEx nR/Ex nR Option S826 Class II and Class III Standard Product Suitable for Class I, Division 2/Class II T6 T6 T5 T5 T4A* — T3A/T5 T3/T4A* — T5 T4* — 90 105 105 T3A/T5 — — T5 — — 90 105 105 70 40 55 65* T3A T3A T3 T6 T6 T5 T5 — — 100 40 55* T2C T2C T5 T4 Consult Factory for Class II Suitability with 105°C Supply Wire 150 40 T2B T4 — — — 105 70 40 55 65* T3C T3C T3C T6 T6 T5 T5 — — T3C/T5 — — T5 — — 90 105 105 100 40 T3 T6 — — — 90 150PS (S828) 40 T2D T5 — — — 105 90 105 METAL HALIDE COMPACT FLUORESCENT 26 40 T3B T6 T6 T3B/T6 T6 75 26 (347 V) 55 40 T3A T3 T6 T6 — — — — — — 75 75 32 40 55 T3B T3A T6 T6 T6 — T3B/T6 — T6 — 75 75 32 (347 V) 40 T6 — — — 75 T3B T6 T6 T3B/T6 T6 75 42 (347 V) 55 40 T3A T3 T6 T6 — — — — — — 75 75 52 40 55 T3 T3 T6 T6 T6 — T3B/T6 — T6 — 75 90 64 40 55 T3 T3 T6 T6 T6 — T3/T6 — T6 — 75 90 84 40 T2C T6 — — — 90 EMERGENCY FLUORESCENT 26 40* T3B T6 — — — 75 6L T3 42 (120–277 V) 40 INDUCTION 55 40* 55* T2D T2D T6 T6 T6 — — — T6 — 75 75 85 40* T2B T6 — — — 75 *Fuses (suffix S658) are not available for indicated light sources and ambient temperatures. Note: Luminaires requiring 105°C supply wire are furnished with 3 ft. of rated wire for external wiring connection. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1127 1128-1129.qxp 12/16/2013 6L 8:40 PM Page 1128 UL/cUL Listed NEMA 4X IP66 Champ® Pro PFM Series Luminaires Perfect for outdoor/indoor flood illumination The Champ® Pro PFM Family Drivers: Champ® Pro PFM Series Floodlights are designed to provide full-spectrum, crisp, white light. Five versions of the Champ PFM LED are available, providing ideal solutions for a wide range of applications. Standard Champ Pro PFM Model Equivalent MH HID Lamp PFM5L PFM7L PFM9L PFM11L PFM13L 100W-150W 150W-175W 175W-250W 250W-400W 400W ® Model 90-305 VAC, 50 / 60 Hz; 108-250 VDC 347 VAC Model 480 VAC Model Option 1 Option 2 Standard Materials: • Housing – copper-free aluminum with Corro-free™ epoxy powder coat • Lens – shatter-resistant glass • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required Energy Savings Up to 62%! Certifications and Compliances: • • • • • 5L - 13L LED System: • High brightness light emitting diode (LED) arrays • Color temperature: 3000K (CRI 82) and 5600K (CRI 65) options available • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions UL1598 UL1598A cUL NEMA 4X; IP66 DesignLights Consortium® approved for select models (refer to Ordering Information for details) Electrical Ratings: PFM5L PFM7L PFM9L PFM13L 100-277V 50-60 Hz Voltage Range, VAC 6L PFM11L 347 / 480V 60 Hz Voltage Range, VDC 108-250 108-250 108-250 108-250 108-250 Input Power (Nom.) 64 89 121 149 179 Input Amps (Max.) 0.550 0.800 1.083 1.608 1.608 Power Factor >0.85 >0.85 >0.85 >0.85 >0.85 Ordering Information: Color Temperature Cool Color Temperature 5L Series 7L Series 9L Series 11L Series 13L Series PFM5LCY/UNV1 76 PFM7LCY/UNV1 76 PFM9LCY/UNV1 76 PFM11LCY/UNV1 76 PFM13LCY/UNV1 76 PFM5LCY/120 76* PFM7LCY/120 76* PFM9LCY/120 76* PFM11LCY/120 76* PFM13LCY/120 76* Warm Color Temperature PFM5LWY/UNV1 76 PFM7LWY/UNV1 76 PFM9LWY/UNV1 76 PFM11LWY/UNV1 76 PFM13LWY/UNV1 76 For 347 VAC option, replace /UNV1 with /347. For 480 VAC option, replace /UNV1 with /480. To order fixture without optics, remove ‘76’ from the end of the catalog number. *5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium approved models. Cool white only. Options: Description Suffix Fused (only applies to UNV1 model, not available for 347V or 480V; NOT marine or cUL Listed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658 Two conduit/cable glands of like thread installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S886 Accessories: Description Catalog No. Sold Separately Bolt-on visor (sold separately) Bolt-on wire guard (sold separately) Floodlight slipfitter (sold separately) Slipfitter wall mount adapter (sold separately) DSV1 P61 SFA6 SWB6 1128 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1128-1129.qxp 12/16/2013 8:40 PM Page 1129 Champ® Pro PFM Series Luminaires 6L UL/cUL Listed NEMA 4X IP66 Perfect for outdoor/indoor flood illumination Dimensions: [167.1] 6.6 [532.9] 21.0 [552.5] 21.75 [405.9] 16.0 [14] Ø.55 [120.7] 4.75 Photometric Data: Weights: Model Lbs. 5L 7L 9L 11L 13L 39.11 39.16 39.73 40.35 40.35 PFM13L @ 30 Ft. High; Tilt Angle = 45 Degrees (Isofootcandles) Ambient Temperature: Champ® Pro PFM Model Max. Temp. ºC PFM5L 55 PFM7L 55 PFM9L 55 55 40 6L PFM13L 40 6L PFM11L 55 Point By Point FC Readings Distance in Feet .35 Fc .5 Fc 1 Fc 2 Fc 2.5 Fc MULTIPLIERS FOR OTHER LED FLOODLIGHTS Luminaire Series Wattage Lumens* PFM5L 64 4386 PFM7L 90 6828 PFM9L 121 8478 PFM11L 188 10481 *PFM 13L output is 13,155. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1129 1130-1131.qxp 12/16/2013 6:57 PM Page 1130 Champ® Pro PFM Series 25L and 50L LED Floodlights 6L UL/cUL Listed NEMA 4X IP66 The Champ® Pro PFM LED Family PFM LED Series Floodlights are designed to provide full-spectrum, crisp, white light. Two versions of the Champ Pro PFM LED are available, providing ideal solutions for a wide range of applications. PFM Model Equivalent HID Lamp Energy Savings PFM25L 750W MH PFM50L 1500W MH / 1000W HPS Applications: 6L PFM25L Model Up to 65%! PFM50L Model • High lumen output for installation in high mounting heights • Locations requiring continuous and consistent light levels • Areas requiring frequent on-and-off of lights • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist; indoors or outdoors • NEMA 4X, marine, wet locations, and hose-down environments • Indoor and outdoor area lighting in plants, buildings, and parking areas • Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; platforms; loading docks; outdoor mounted general area lighting • Ball mills, stackers and reclaimers, concentrators, smelters, mine roadways, outdoor processing areas, truck service shops, shovels, and drag lines Certifications and Compliances: Standard Materials: • Housing – copper-free aluminum with Corro-free™ epoxy powder coat • Lens – heat- and impact-resistant glass • Yoke mount (standard) – copper-free aluminum with Corro-free™ epoxy powder coat • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required LED System: • High brightness light emitting diodes (LEDs) • Color temperature: 5000K (CRI 67) • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions • LM-79, LM-80 reports available upon request Options: Description Two conduit/cable glands of like thread installed ................... Diffused glass lens .................... Polycarbonate lens.................... Suffix S886 S891 S903 Accessories: Description Cat. # (Sold Separately) Bolt-on visor (sold separately).................... Bolt-on wire guard (sold separately).................... Floodlight slipfitter (sold separately).................... Slipfitter wall mount adapter (sold separately).................... DSV1 P61 SFA6* SWB6* *Available with PFM25L model only. Drivers: PFM Model /UNV1 /UNV34 25L, 50L 90-305 VAC, 50 / 60 Hz; 127-250 VDC 277-480 VAC Model Electrical Ratings: • • • • • UL1598 UL1598A cUL NEMA 4X; IP66 DesignLights Consortium® approved for select models (refer to Ordering Information for details) • UL approved up to 40°C ambient PFM25L PFM50L 120-277V 50 / 60 Hz Voltage Range, VAC 277-480V 50 / 60 Hz Voltage Range, VDC 127-250V Input Power (Nom.) 263 531 Input Amps (Max.) 2.6 5.2 Power Factor >0.90 Ordering Information: 25L Series†* 50L Series PFM25LCY/UNV1 76 PFM50LCY/UNV1 76 NOTE: Available in cool color temperature only. For 277-480 VAC option, replace /UNV1 with /UNV34. †DesignLights Consortium® approved model at 120-277V. *PFM25L is DLC approved with a 5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard terms and conditions. 1130 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1130-1131.qxp 12/16/2013 6:57 PM Page 1131 Champ® Pro PFM Series 25L and 50L LED Floodlights UL/cUL Listed NEMA 4X IP66 6L Safe, reliable heat transfer High efficiency and lumen output The heat sink was designed to perform in high ambient temperatures up to +40ºC and as low as -25ºC. The thick walls of the castings make for a tough, rugged housing that keeps the internal driver and LED temperatures down, allowing them to perform flawlessly, and protects them from damage. Separated driver and LED housing allows dust to shed from fixture. High efficiency drivers and LEDs provide 100 LPW for reliable low cost operation in industrial environments. Components were chosen to give industry-leading light output from an LED flood. Replaceable drivers and LEDs for ease of maintenance and “no lights out” feature. 6L 6L Versatile design Can be used for outdoor or indoor applications, and for a wide range of mounting heights depending on model and light level requirement. Optics were specifically designed to give the familiar and industry-accepted NEMA 7x6 beam light pattern. www.crouse-hinds.com Optional equipment (sold separately) Optional visor offered to control light spill. Optional wire guard offered to protect lens from damage. Other options available - consult part numbering guide. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1131 1132-1133.qxp 12/16/2013 7:42 PM Page 1132 Champ® Pro PFM Series 25L and 50L LED Floodlights 6L UL/cUL Listed NEMA 4X IP66 Dimensions: 532.9 21.0 277 10.9 234.5 9.2 552.5 21.75 203.7 8.0 405.9 16.0 525.6 20.7 120.7 4.75 .55 PFM25L Model 277 10.90 556.3 21.90 254 10.00 235.8 9.28 532.9 20.98 203.7 8.02 13.9 Ø .55 127 5.00 825 32.48 632.6 24.90 6L PFM50L Model Photometric Data: Weights: PFM50L @ 50 Ft. High PFM25L @ 50 Ft. High 200 200 175 150 125 100 75 50 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.6 0.7 0.7 0.7 0.8 0.7 0.7 0.7 0.6 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.5 0.6 0.7 0.8 0.9 0.9 0.9 0.9 0.9 0.8 0.7 0.6 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.8 0.9 1.0 1.1 1.2 1.2 1.2 1.1 1.0 0.9 0.8 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.7 0.7 0.8 0.7 0.7 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.6 0.7 0.9 1.1 1.3 1.5 1.6 1.6 1.6 1.5 1.3 1.1 0.9 0.7 0.6 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.8 0.9 1.0 1.0 1.0 0.9 0.8 0.7 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.6 0.8 1.1 1.4 1.7 1.9 2.1 2.1 2.1 1.9 1.7 1.4 1.1 0.8 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.2 0.3 0.4 0.5 0.7 0.9 1.3 2.8 2.9 2.8 2.2 1.7 1.3 0.9 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.2 0.3 0.4 0.5 0.7 1.0 1.5 2.0 2.7 3.3 3.7 3.9 3.7 3.3 2.7 2.0 1.5 1.0 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.2 0.2 0.4 0.5 0.8 1.1 1.7 2.4 3.4 4.3 5.0 5.1 5.0 4.3 3.4 2.4 1.7 1.1 0.8 0.5 0.4 0.2 0.2 0.2 0.2 0.4 0.6 0.9 1.3 2.1 3.2 4.6 6.3 7.4 7.9 7.4 6.3 4.6 3.2 2.1 1.3 0.9 0.6 0.4 0.2 0.2 0.1 0.1 0.2 0.3 0.4 0.7 1.1 1.9 3.0 6.5 8.0 8.5 8.0 6.5 4.5 3.0 1.9 1.1 0.7 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.1 0.1 0.1 0.2 0.2 0.4 0.1 0.1 0.1 0.2 0.3 0.4 0.1 0.1 0.1 0.2 0.3 0.0 0.1 0.1 0.1 0.2 0.5 0.5 0.6 1.1 1.2 1.3 1.6 1.7 2.1 2.4 1.6 2.3 3.1 3.7 1.5 2.2 3.1 3.8 0.8 0.7 1.0 0.6 0.8 1.2 0.4 0.7 1.0 0.3 0.6 0.9 175 150 125 100 75 50 1.3 1.4 1.3 1.2 1.1 0.8 0.6 0.5 0.3 0.2 0.2 0.1 0.1 0.1 1.8 1.9 1.8 1.6 1.3 1.0 0.7 0.5 0.4 0.2 0.2 0.1 0.1 0.1 2.5 2.4 2.1 1.7 1.2 0.8 0.6 0.4 0.3 0.2 0.1 0.1 0.1 3.9 3.7 3.1 2.3 1.6 1.0 0.7 0.4 0.3 0.2 0.1 0.1 0.1 0.1 3.8 3.1 2.2 1.5 0.9 0.6 0.3 0.2 0.1 0.1 0.1 0.0 0.1 2 25 0 .1 .25 .5 1 1.5 3 4 4.1 25 0 0.25 0.15 0.5 1 1.5 Point By Point Foot-Candle Readings -125 -100 -75 -50 -25 0 25 1.7 2.2 2 4 4.5 0.25 0.50 1.00 1.50 50 75 100 125 -125 -100 -75 -50 2.6 -25 0 25 75 50 2.00 3.00 4.00 0.15 0.25 0.50 1.00 0.2 0.1 100 125 1.50 2.00 3.00 4.00 5.00 Footcandles Luminaire Series Wattage Lumens Luminaire Series Wattage Lumens PFM25L 263 26,240 PFM50L 531 53,890 www.crouse-hinds.com 52.00 106.00 Distance In Feet Footcandles 1132 5 3 Lbs. PFM25L PFM50L Point By Point Foot-Candle Readings Distance In Feet 0.10 2.6 PFM Model US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1132-1133.qxp 12/16/2013 7:42 PM Page 1133 6L Cl. I, Div. 2 Cl. I, Zone 2 Champ® Floodlight Family The Standard for Safety and Reliability Whenever Eaton's Crouse-Hinds develops a new product, system, or procedure, we focus on one overriding question: Will it lower the total cost of ownership for our customers? With our new expanded line of Champ® Floodlights, the answer is most definitely, “Yes.” Eaton's Crouse-Hinds utilized more than 100 years of hazardous lighting expertise to design a global floodlight line of unmatched reliability, quality, and performance for your area lighting needs. • Energy-efficient with optimal light output and beam distribution • The most accessible ballast assembly in the industry • Restricted breathing is standard on all floodlights • Offered with both North American ballast (made to ANSI standard) and European style IEC ballast gear (pending) • UL marine rated, NEMA Type 4X and IP66 6L 6L Champ FMV nR Series Floodlight Champ F2MV Mini-Floodlight The Champ FMV nR Series Floodlight offers exceptional indoor and outdoor illumination in industrial areas. Because of its superior corrosion resistance and restricted breathing being standard, the FMV floodlight is the ideal choice for diverse industrial applications that include wet and marine environments. Differentiations: • Full frame trunnion mounting bracket • Restricted breathing standard • 55°C and 65°C ambient air suitability • Standard with terminal blocks • Class I, Division 2/Zone 2 • Removable ballast tray The F2MV is a compact floodlight that consists of a Corro-Free™ epoxy coated copper-free aluminum enclosure with stainless steel external hardware and an impact-resistant glass lens. It is suitable for marine and wet locations and is ideal where space constraints restrict the use of larger floodlights. Differentiations: • Small, compact size • Easy mounting installation—only 2 bolts! • Powerful light distribution for floodlight and task applications • Rated for use in 65°C ambient air for hazardous location applications www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1133 1134-1135.qxp 12/16/2013 6:58 PM Page 1134 Champ® Floodlight Family 6L Cl. I, Div. 2 Cl. I, Zone 2 The Standard for Safety and Reliability Champ Voyager nR™ Stainless Steel Floodlight The Champ FMV1000 nR prides itself on offering restricted breathing and easy-to-wire terminal blocks as standard components. It is NEMA Type 4X and IP56 watertight and due to its heavy-duty vaportight, copper-free aluminum housing and stainless steel hardware, it is exclusively designed for harsh and industrial areas requiring broad area lighting. The Champ FMV1000 nR provides a robust design for optimal use in the most corrosive/marine environments. Differentiations: • Hazardous location high wattage floodlight for Class I, Division 2, Zone 2 • Restricted breathing standard • T3 rating in Class I, Zone 2 • 40°C and 55°C ambient air suitability • Hinged removable door • Available in 600, 750, 1000, and 1500W systems (1500W for non-hazardous locations only) The Champ Voyager nR Floodlight offers the industry's coolest temperature rating and is the only mogul-base Class I, Division 2 and Zone 2 stainless steel floodlight with restricted breathing as standard construction. It boasts a wide, powerful beam to deliver more light to your process, and with the standard terminal block and removable ballast-component tray, the Champ Voyager is perfect for outdoor, marine, corrosive, and high temperature locations. Differentiations: • Housing, door and external parts are all 316 stainless steel • Restricted breathing standard with T-ratings of T3 and T4 • Pre-wired with terminal blocks for easy wiring • Hinged door and removable ballast tray 6L Champ FMV1000 nR High Wattage Floodlight Product Selector Chart F2MV MINI FMV nR FMV1000 nR Voyager nR Hazardous Class I, Division 2 Class I, Zone 2 • • • • Hazardous Restricted Breathing (Ex nR) NEC/CEC: Class I, Division 2 Class I, Zone 2 IEC Zone 2 • • • • ATEX Certification with IEC Ballast and Lamp Socket IEC Zone 2 Ex nR II ATEX pending • Wet • • • • Marine • • • • NEMA Type 4, 4X • • • • NEMA 7x6 • • • • Corrosion Resistant • • • • 150–400 175–400 600, 750, 1000 1000, 1500 150–400 175–400 Confined Areas Wattage 1134 • High Pressure Sodium Metal Halide www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 50–150 70–175 • Copyright© 2013 Eaton’s Crouse-Hinds Business 1134-1135.qxp 12/16/2013 6:58 PM Page 1135 Champ® FMV nR Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II Cl. II, Div. 1, Groups F, G (up to 250W) The Champ FMV nR Series Floodlight offers exceptional illumination in industrial areas, both indoors and out. And, it comes standard as a restricted breathing luminaire. The Champ FMV nR Series Floodlight is easily adjusted to aim light where it’s needed and is available in a wide variety of energy-saving mogul base HID light sources and wattages including: • 150–400W High Pressure Sodium • 175–400W Metal Halide Applications: The FMV is made with heavy-duty, diecast aluminum components and stainless steel hardware. It offers superior corrosion resistance to ensure longer life, which makes the FMV floodlight the ideal choice for a wide variety of industrial applications, including wet and marine environments. Features and Benefits: • Heavy-duty, die-cast copper-free aluminum enclosure with epoxy coating and stainless steel hardware—provides a robust design with industrial grade construction and corrosion resistance • Hinged door frame assembly—has captive cover screws for ease of relamping • Yoke mount design—standard construction provides the greatest mounting flexibility, can be mounted vertically (wall), horizontally (rooftop or floor), or any angle in between Certifications & Compliances: NEC/CEC (NEC Ballast Gear and Socket): • Class I, Division 2, Groups A, B, C, D • Class I, Zone 2, AEx nR II • Class II, Division 1, Groups F, G (up to 250W) • Marine locations • NEMA Type 4X and IP66 • Wet locations IEC (IEC Ballast Gear and Socket): • IEC Zone 2, Ex nR II (pending) UL/cUL Standards: • 844—Hazardous (Divisions Classified) Locations • 60079-15 • 1598—Luminaires • 1598A—Supplemental Requirements for Luminaires for Installation on Marine Vessels IEC Standards: • 60079-15 6L The only full frame trunnion mount floodlight with a T3 rating and a removable ballast tray assembly. Industry Best for Ease of Installation: 1. Removable ballast tray 2. Prewired to terminal blocks 3. Substantial room for wiring Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) • HPS—150, 250, and 400W • MH—175, 250, and 400W Voltages Standard Materials: • Fixture housing and door frame assembly—die-cast aluminum • External hardware—stainless steel • Lens—heat- and impact-resistant tempered glass • Yoke—aluminum Standard Finishes: • Enclosure and yoke—Corro-Free™ epoxy powder coat • Stainless steel—natural www.crouse-hinds.com Standard Voltage Ballasts • Multi-tap (120, 208, 240, and 277V 60Hz) • Dual-tap (120 and 277V) • 480V 60Hz • Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts • 220V or 240V 50Hz (for export) • 220V 60Hz (for export) Isolated Ballasts • 208, 240, or 480V (for Canada) Hub Size • Standard—3/4" NPT • Optional—25 mm (M25 x 1.5) or 20 mm (M20 x 1.5) US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1135 6L • AEx nR, Ex nR restricted breathing rating is standard—a hazardous location luminaire without additional accessories or options; restricted breathing offers cooler T-numbers for increased hazardous locations suitability • NEMA 7x6 butterfly beam floodlight pattern—wide, uniform and far reaching to provide excellent efficiency and more light where you need it • NEMA Type 4X and IP66 construction is designed for use indoors and outdoors in marine and wet locations—with stainless steel external hardware suitable for saltwater and corrosive applications • Easy wiring—standard terminal block with marked terminals saves time and eliminates wiring errors • Vapor-tight sealing cable connector— standard • Will accommodate existing mounting hardware—SFA6 slipfitter for pole and SWB6 wall mount • Optional metric machining will accept M20 or M25 (must be specified on order) • 40°C, 55°C and 65°C ambient suitability—addresses high ambients common at industrial facilities • Low ambient capability to -40°C— perfect for colder climates • 3-axis resonance withstand and UL844 vibration compliant—can stand up to the tough jobs • Precision formed aluminum reflector— superior beam control, distribution and efficiency • Multi-tap ballasts—offering a choice of 120, 208, 240 and 277V; 220V 50Hz, 240V 50Hz, Tri-Tap (120, 277 and 347), and 480V ballasts are also available • High light output with a low cost of operation—cost-effectiveness in a high wattage floodlight • For use with SFA6 Slipfitter Adapter and SWB6 Wall Mount Bracket accessories—further enhances mounting flexibility Marine locations NEMA Type 4X and IP66 Wet locations 1136-1137.qxp 12/16/2013 6:58 PM Page 1136 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II Champ® FMV nR Floodlights 6L Photometric Data: Ordering Information for Floodlight with NEC Ballast: Lamp Type Watts 150 Yoke Mount 3/ 4" NPT Hub FMVSY150/MT 76 High Pressure Sodium 250 FMVSY250/MT 76 400 FMVSY400/MT 76 175 FMVMY175/MT 76 250 FMVMY250/MT 76 400 FMVMY400/MT 76 Metal Halide Isofootcandle Chart FMV 400W High Pressure Sodium (HPS) Catalog Number: FMVSY400-76 Lamp: 400W Clear HPS Lumen Rating: 50,000 For 150W HPS, multiply footcandles by .32. For 250W HPS, multiply footcandles by 0.6. Fixture located at 0°, 0° aiming angle at 45° Voltage Suffixes† Voltage (60Hz) Suffix Dual-Tap /DT (Note: See Figures 1 and 2). Tri-Tap /TT Multi-Tap /MT 480 /480 Isofootcandle Chart FMV 400W Metal Halide (MH) Catalog Number: FMVMY400-76 Lamp: 400W Clear MH Lumen Rating: 34,000 For 250W MH, multiply footcandles by 0.6. Fixture located a 0°, 0° aiming angle 45° To complete catalog number, add voltage and options suffix(es). Options Example: FMVMY400/MT 76 M25 V2PC20 Series Yoke Lamp Type Voltage Watt Beam Spread Metric Entry Photocell †150W HPS fixtures are furnished with ANSI spec/S55 ballasts for 55V lamps. For 100V lamps, add suffix "CE" after voltage suffix. Example: FMVSY150/MT CE 76. (Note: See Figures 1 and 2). 6L Options: Effective Projected Area (EPA): Description Suffix Instant Restrike and Ballast Guard Instant restrike—enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage Ballast guard starter cut out switch—prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. • 150W LX HPS only.............................................................. TIR Factory assembled with HID lamp installed ......................... FA Fused (not suitable for marine applications)......................... S658 20mm metric thread for conduit opening ............................. M20 25mm metric thread for conduit opening ............................. M25 3 / 4" NPT hub conduit opening ............................................... NPT75 Furnished with lamps (not installed) ..................................... S714 Retention chain ..................................................................... S831 Pulse-Start Metal Halide ....................................................... S828 Enclosure machined for 2 conduit/cable entries .................. S886 Options for Photocell*: • For windloading • For proper pole selection Aiming Angle EPA 0° 30° 45° 2.9 FT2 2.5 FT2 2.1 FT2 Footcandle Table: Mounting Height 15' 20' 25' 30' 35' 40' A 8.0 4.5 2.9 2.0 1.5 1.1 Footcandle Values for Isofotcandle Lines B C D E 4.0 2.0 0.80 0.40 2.3 1.1 0.50 0.23 1.4 0.7 0.30 0.14 1.0 0.5 0.20 0.10 0.7 0.4 0.15 0.07 0.6 0.3 0.11 0.06 Description Suffix Photocell 120V, 50/60Hz installed ....................................... V2PC20 Photocell 208-240V, 50/60Hz installed ................................ V2PC22 Photocell 277V, 50/60Hz installed ....................................... V2PC27 *Photocell for Div. 2 installation only. Accessories (Order Separately): Slipfitter Adapter To be mounted to yoke mount fixture Fits onto 2" pipe/conduit ............................................... Wall Bracket Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability..................... 1136 www.crouse-hinds.com Marine locations NEMA Type 4X and IP66 Wet locations US: 1-866-764-5454 SFA6 SWB6 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1136-1137.qxp 12/16/2013 6:59 PM Page 1137 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II Champ® FMV nR Floodlights 6L Marine locations NEMA Type 4X and IP66 Wet locations Weights and Dimensions: Net Fixture Weights (Lbs.): Fixtures 150W 175–250W 400W FMVS 37 40 44 FMVM 37 42 44 SFA6 (Slipfitter Adapter)—Add 4 lbs., SWB6 (Wall Bracket)—Add 6 lbs. 18.0 [458.0] 6.8 [173.9] 20.0 [508.0] 23.6 [600.1] 19.1 [485.8] 4.8 [120.7] 30° 30° 60° FIGURE 2 FIGURE 1 www.crouse-hinds.com 180° 120° 90° US: 1-866-764-5454 CAN: 1-800-265-0502 6L 90° .6 DIA. [14.3] 90° 90° FIGURE 3 Copyright© 2013 Eaton’s Crouse-Hinds Business 1137 1138-1139.qxp 12/16/2013 6L 7:00 PM Page 1138 Champ® FMV nR Floodlights Cl. I, Div. 2, Groups A,B,C,D Cl. I, Zone 2, AEx nR II Marine locations NEMA Type 4X and IP66 Wet locations Temperature Performance Data: 40°C Ambient Lamp Catalog Series Type Temperature Code Watts High Pressure Sodium Temperature Code Supply Wire °C Class I, Zone 2 Class I, Div. 2 Supply Wire °C Class I, Zone 2 Class I, Div. 2 Supply Wire °C T4 T4 T3 T4 T4 T3 T3 T3 T3 T4 T4 T3 T4 T4 T3 T3 T3 T3 T4 T4 T3 T4 T4 T3 T3 T3 T3 325 325 325 325 325 325 T1 T1 T1 325 325 350 325 325 350 325 325 T1 325 325 350 325 325 350 350 350 T1 90 90 90 90 90 90 90 105 105 90 90 90 90 90 90 90 105 105 90 90 90 90 90 90 105 105 105 T4 T3 T3 T4 T3 T3 T3 T3 T3 T4 T4 T3 T4 T4 T3 T3 T3 T2 T3 T3 T3 T3 T3 T3 T3 T3 T3 325 325 325 325 325 325 T1 T1 T1 325 325 350 325 325 350 325 325 T1 325 325 T1 325 325 T1 350 T1 T1 90 105 105 90 105 105 105 125 125 90 105 125 90 105 125 105 125 125 105 105 105 105 105 105 105 125 125 T3 T3 T3 T3 T3 T3 – – – T3 T3 T3 T3 T3 T3 – – – T3 T3 T3 T3 T3 T3 – – – 325 325 325 325 325 325 – – – 325 325 T1 325 325 T1 – – – 325 325 T1 325 325 T1 – – – 105 105 105 105 105 105 – – – 105 105 105 105 105 105 – – – 105 105 105 105 105 105 – – – 250 175 250* 400** FMVM 175 PulseStart Metal Halide Temperature Code Class I, Div. 2 400** Metal Halide Fixture Aiming 65°C Ambient Class I, Zone 2 150 FMVS 55°C Ambient 250* 320** 350** 400** Range Figure 90° 120° 180° 90° 120° 180° 90° 120° 180° 90° 120° 180° 90° 120° 180° 90° 120° 180° 90° 120° 180° 90° 120° 180° 90° 120° 180° *Suitable for use in 65°C ambient without optional fuses. **Suitable for use in 55°C ambient without optional fuses. 6L Lamp Selection (Mogul Base): Fixture Watts Type Bulb FMVSY150 FMVSY250 FMVSY400 FMVMY175 FMVMY250 FMVMY400 150 250 400 175 250 400 ED23 ED18 ED37 ED28 ED28 ED37 HPS HPS HPS MH MH MH / 2 BT25 1 / 2 or ET18 1 / 2 BT37 or BT28 or BT28 or BT37 1 G.E. Osram Philips LU150/55 LU250 LU400 MVR175/U MVR250/U MVR400/U LU150/55 LU250 LU400 M175/U M250/U M400/U C150S55 C250S50 C400S51 MH175/U MH250/U MH400/U Photometrics are available online. 1138 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1138-1139.qxp 12/16/2013 7:00 PM Page 1139 Champ® FMV1000 nR High Wattage Floodlights Cl. I, Div. 2, Groups A, B, C, D Marine locations Cl. I, Zone 2, AEx nR II, Group IIC NEMA Type 4X and IP56 Wet locations 6L The Champ FMV1000 Series High Wattage Floodlight is the best in its class with heavy-duty vapor-tight housing designed exclusively for harsh industrial areas requiring broad area lighting. The FMV1000 Series Floodlight boasts restricted breathing and easy-to-wire terminal blocks as standard. It is available in the following HID lamp sources and wattages: • 600, 750, 1000W High Pressure Sodium • 1000, 1500W Metal Halide Restricted breathing comes standard with this NEMA Type 4X and IP56 rated floodlight. Applications: The Champ FMV1000 Series is NEMA Type 4X and IP56 watertight, and its heavy-duty welded extruded aluminum housing and stainless steel hardware provide a robust design suitable for the most corrosive/marine environments. Features and Benefits: Certifications & Compliances: NEC/CEC (NEC Ballast Gear and Socket): • Class I, Division 2, Groups A, B, C, D • Class I, Zone 2, AEx nR II, Group IIC • Marine locations • IP56 • Wet locations • NEMA Type 4X • Aluminum—Corro-Free™ epoxy powder coat • Stainless steel—natural Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) • HPS—600, 750, and 1000W • MH—1000W • MH—1500W non-hazardous location rated Standard Voltage Ballasts • Multi-tap (120, 208, 240, and 277V 60Hz) • 480V 60Hz • Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts • 220V or 240V 50Hz (for export) • 220V 60Hz (for export) Isolated Ballasts • 208, 240, or 480V (for Canada) Housing—extruded aluminum External hardware—stainless steel Yoke—316 stainless steel Lens—heat- and impact-resistant tempered glass Gasketing—neoprene www.crouse-hinds.com Standard Finishes: Voltages: Standard Materials: • • • • • Industry Best for Ease of Installation: 1. Removable ballast tray 2. Prewired to terminal blocks 3. Substantial room for wiring 6L • AEx nR, Ex nR restricted breathing rating is standard—a hazardous location luminaire without additional accessories or options; restricted breathing offers cooler T-numbers for increased hazardous locations suitability • NEMA 7x6 butterfly beam floodlight pattern—wide, uniform and far reaching to provide excellent efficiency and more light where you need it • NEMA Type 4X and IP56 construction is designed for use indoors and outdoors in marine and wet locations—with stainless steel external hardware suitable for saltwater and corrosive applications • Easy wiring—standard terminal block with marked terminals saves time and eliminates wiring errors • Vapor-tight sealing cable connector—standard • Standard machining—will accept 3/4 inch NCGB or 3/4 inch Myers™ hub (Myers hub is an option). Optional metric machining will accept M20 or M25 (must be specified on order) • Low and high ambient capability to -40°C—perfect for colder climates, 50°C workhorse in hot climates • Heavy-duty, extruded copper-free aluminum enclosure with epoxy coating and stainless steel hardware—provides a robust design with industrial grade construction and corrosion resistance • Precision formed aluminum reflector—superior beam control, distribution and efficiency • High light output with a low cost of operation—cost-effectiveness in a high wattage floodlight Hub Size: • 3/4" NPT—standard • M20 or M25—optional • Dual entry—NPT or metric US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1139 1140-1141.qxp 12/16/2013 7:00 PM Page 1140 Champ® FMV1000 nR High Wattage Floodlights 6L Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II, Group IIC Marine locations NEMA Type 4X and IP56 Wet locations Ordering Information for Floodlight with NEC Ballast: Lamp Type High Pressure Sodium Metal Halide Watts Base Catalog Number* 600 750 1000 1000 1500 FMVSY600__ 76 FMVSY750__ 76 FMVSY1000__ 76 FMVMY1000__ 76 FMVMY1500__ 76 *To complete catalog number, add voltage and options suffix(es). Voltage Suffixes: Voltage (60Hz) Dual-Tap Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 Options Example: FMVS Y1000/MT 76 M25 S828 Series Yoke Lamp Type Voltage Metric Pulse-start Entry Metal Halide Only Beam Spread Watt Temperature Performance Data: 40°C Ambient Lamp 75° 30° Fixture Aiming 50°C Ambient Temperature Code Temperature Code 45° Catalog Series FMVS Figure 1 90° 30° 60° 6L FMVM Type Wattage Class I, Zone 2 Class I, Div. 2 Supply Wire °C Class I, Zone 2 Class I, Div. 2 Supply Wire °C Range Figure High Pressure Sodium Metal Halide PulseStart Metal Halide 600 750 1000 T3 T3 T3 T1 T1 T1 90 90 90 TS T3 T3 T1 T1 T1 105 105 105 90° 90° 90° 2 2 2 1000 T3 T1 90 T3 T1 105 90° 2 750 750 1000 1000 T3 T3 T3 T3 T1 T1 T1 T1 90 90 90 90 T3 – T3 – T1 – T1 – 105 – 105 – 75° 90° 75° 90° 1 2 1 2 Accessories (Order Separately): Slipfitter adapter: To be mounted to yoke mount fixture; fits onto 2" pipe/conduit....................................... SFA6 Wall bracket: Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability............... SWB6 Photocell in DS cover for use with FS/FD box: 120V, 50/60Hz................................................................................................................................................. D2S20 208-277, 50/60Hz............................................................................................................................................ D2S208 277 Options: 540 21.3 Description Suffix 20mm metric thread for conduit opening........................... M20 25mm metric thread for conduit opening........................... M25 3 /4" NPT hub conduit opening............................................. NPT75 Pulse-start metal halide only.............................................. S828 Retention chain................................................................... S831 Enclosure machined for 2 conduit/cable entries................ S886 FA Factory assembled, lamp installed in lampholder.............. 557.5 21.9 30.1 Weights and Dimensions: Net Fixture Weights (Lbs.): Fixture Series FMVSY600 FMVSY750 FMVSY1000 FMVMY1000 FMVMY1500 1140 www.crouse-hinds.com 78 76 83 76 84 US: 1-866-764-5454 CAN: 1-800-265-0502 13.5 Ø .5 MTG HOLES Copyright© 2013 Eaton’s Crouse-Hinds Business 120.7 4.8 279.2 11.0 1140-1141.qxp 12/16/2013 7:00 PM Page 1141 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II, Group IIC Champ® FMV1000 nR High Wattage Floodlights Marine locations NEMA Type 4X and IP56 Wet locations 6L Effective Projected Area (EPA): • For windloading • For proper pole selection Aiming Angle EPA 0° 30° 60° 3.5 FT2 3.6 FT2 2.9 FT2 Photometric Data: ISO Footcandle Chart FMV 1000W High Pressure Sodium (HPS) Catalog Number: FMVSY1000-76 Lamp: 1000W Clear HPS Lumen Rating: 140,000 Fixture located at 0°, 0° aiming angle at 45° (Note: See Figures 1 and 2). ISO Footcandle Chart FMV 1000W Metal Halide (MH) Catalog Number: FMVMY1000-76 Lamp: 1000W Clear MH Lumen Rating: 110,000 For 1500W MH, multiply footcandles by 1.4 Fixture located a 0°, 0° aiming angle at 45° (Note: See Figures 1 and 2). 6L Footcandle Table for FMVS1000W: Footcandle Values for Isofootcandle Lines Mounting Height A B C D E 20' 25' 30' 35' 40' 12.6 8.1 5.6 4.2 3.1 6.4 3.9 2.8 2.1 1.6 3.1 2.0 1.4 1.0 0.8 1.4 0.8 0.6 0.42 0.32 0.64 0.4 2.8 0.2 0.17 Lamp Selection (Mogul Base): Fixture FMVSY600 FMVSY750 FMVSY1000 FMVMY750 FMVMY1000 FMVMY1500 Watts Type Bulb G.E. Osram Philips 600 HPS 750 HPS 1000 HPS 750 MH 1000 MH 1500 MH T15 ED37 E25 ED37 BT56 BT56 LU600/T LU750 LU1000 MVR750/VBU/PA MVR1000/U MVR1500/U/SPORTS — — — — — — C600S106 — C1000S52/ED37 — MH1000/U MH1500/U www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1141 1142-1143.qxp 6L 12/16/2013 7:00 PM Page 1142 Champ® Voyager nR™ Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II, Group IIC IEC Zone 2, Ex nR II ATEX Marine locations Wet locations Eaton's Crouse-Hinds Champ® Voyager nR™ Stainless Steel Floodlight offers the industry’s coolest temperature ratings—so it can operate below the ignition temperature of vapors and gases in your classified area. The Champ Voyager nR Floodlight boasts a wide, powerful beam to deliver more light to your process or pathway. Standard terminal blocks and a removable ballast component tray bring you the best combination of easy wiring and simple maintenance in one rugged package. Applications: This unique combination of features makes the Champ Voyager nR Floodlight ideal for outdoor, marine, corrosive, and high temperature locations. And because the Champ Voyager nR Floodlight meets international standards, you can install it anywhere in the world. Features and Benefits: • AEx nR, Ex nR restricted breathing rating is standard—a hazardous location luminaire with excellent T3 and T4 ratings without additional accessories or options • NEMA 7x6 "butterfly beam" floodlight pattern—wide, uniform and far reaching to reduce the number of luminaires you need, providing excellent luminaire efficiency—more light where you need it • Easy wiring—standard terminal block with marked terminals saves time and eliminates wiring errors • Removable ballast component tray—for capacitor, igniter and terminal block to simplify maintenance and save money • Housing, hinges, door frame and mounting yoke are all 316 stainless steel for marine and wet locations—robust construction suitable for saltwater and corrosive applications Now available with IEC gear and certified to the IECEx/ATEX Directive. The only mogul base Class I, Division 2 and Zone 2 stainless steel floodlight with restricted breathing (vapor-tight design) as standard construction. 6L Certifications & Compliances: NEC/CEC (NEC Ballast Gear and Socket): • Class I, Division 2, Groups A, B, C, D • Class I, Zone 2, AEx nR II, Group IIC • NEMA Type 4X and IP66 IEC (IEC Ballast Gear and Socket): • IEC Zone 2, Ex nR II ATEX UL/cUL Standards: • 844—Hazardous (Divisions Classified) Locations • 1598—Luminaires Marine Locations • 1598A—Supplemental Requirements for Luminaires for Installation on Marine Vessels Standard Materials: • • • • • • Enclosure (housing and lens frame)—316 stainless steel Lens—heat- and impact-resistant tempered glass Gaskets—silicone rubber Yoke and yoke bracket—316 stainless steel Reflector—formed specular (dimpled glossy surface) aluminum Cable gland cord grip and locknut—polyamide 6, neoprene bushing Standard Finishes: • 316 stainless steel—natural Photometrics are available online. Industry Best for Ease of Installation: 1. Removable ballast tray 2. Prewired to terminal blocks 3. Substantial room for wiring Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) • High Pressure Sodium (HPS) 150, 250, and 400W • Metal Halide (MH) 175, 250, and 400W Voltages: Standard Voltage Ballasts • Multi-tap (120, 208, 240, and 277V 60Hz) • 480V, 60Hz • Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts (for export) • 220V or 240V, 50Hz • 220V, 60Hz Isolated Ballasts • 208, 240, or 480V (for Canada) Hub Size: • Standard: 3/ 4" NPT with a 3/ 4" gland sealing connector 1142 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1142-1143.qxp 12/16/2013 7:00 PM Page 1143 Champ® Voyager nR™ Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II, Group IIC IEC Zone 2, Ex nR II ATEX Ordering Information for Floodlight with IEC Ballast: Lamp Type IEC Ref. HPS HSE/HST MH HIE 6L Marine locations Wet locations Ordering Information for Floodlight with NEC Ballast: Watts Catalog Number* 150 250 400 150 250 400 NSSFMVSY150/220 NSSFMVSY250/220 NSSFMVSY400/220 NSSFMVMY150/220 NSSFMVMY250/220 NSSFMVMY400/220 Lamp Type Watts Catalog Number* High Pressure Sodium 150 250 400 175 250 400 SSFMVSY150__ 76 SSFMVSY250__ 76 SSFMVSY400__ 76 SSFMVMY175__ 76 SSFMVMY250__ 76 SSFMVMY400__ 76 Metal Halide Voltage Suffixes: *Uses IEC lamp socket E40. Voltage NSSFMV Floodlights are designed with IEC ballast gear and lamp socket, providing certification to the IEC Ex ATEX Directive. Tri-Tap (120, 277, 347V, 60Hz) Multi-Tap 120, 208, 240, 277V, 60Hz) 480V, 60Hz 240V, 60Hz Suffix Voltage Suffix /TT 220 50Hz /220 50 /MT 220 60Hz /220 /480 /MV 240 50Hz 240 60Hz /240 50 /240 60 *To complete catalog number, add voltage and options suffix(es) Example: SSFMVSY150/MT 76. Temperature Performance Data: 55°C Ambient 40°C Ambient Lamp Catalog Series Temperature Code Fixture Aiming Temperature Code Type Watts Class I, Zone 2 Class I, Div. 2 Supply Wire °C Class I, Zone 2 Class I, Div. 2 Supply Wire °C Range Figure SSFMVS High Pressure Sodium SSFMVM Metal Halide 150** 250** 400 175** 250** 400 T4 T4 T3 T3 T3 T3 T2B 350 T1 T2 325 325 90 90 90 90 90 105 T4 T3 – T3 T3 – T2B 350 – T2 325 – 105 105 – 105 105 – 120° 90° 90° 120° 90° 90° 2 1 1 2 1 1 **Suitable for use in 55°C ambient without optional fuses. For U.S. market, use MH Pulse Start option. 6L Accessories (Order Separately): Stainless steel slipfitter adapter........................................... SFA6 SS Stainless steel wall mount bracket....................................... SWB6 SS Standard slipfitter adapter SFA6 (cast aluminum).................................................................. Standard wall mount bracket SWB6 (cast aluminum).................................................................. Photocell in DS cover for use with FS/FD box: 120V, 50/60Hz.................................................................... D2S20 208-277V, 50/60Hz............................................................ D2S208 277 FIGURE 1 FIGURE 2 Photometrics are available online. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1143 1144-1145.qxp 12/16/2013 6L 7:01 PM Page 1144 Champ® Voyager nR™ Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II, Group IIC IEC Zone 2, Ex nR II ATEX Marine locations Wet locations Effective Projected Area (EPA): • For windloading • For proper pole selection Aiming Angle EPA 0° 30° 60° 2.15 FT2 1.86 FT2 1.07 FT2 Weights and Dimensions: Net Fixture Weights (Lbs.) Luminaire 150W 175W 250W 400W HPS 39 39 43 45 MH 39 39 41 43 [1.77”] (45mm) 6L Options: Description Suffix Instant Restrike and Ballast Guard Instant Restrike—enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage Ballast guard starter cut out switch—prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life............................................................................................................................................. TIR • 150W LX HPS only Factory assembled with HID lamp installed.................................................................................................................................................. FA Fused (not suitable for marine applications).................................................................................................................................................. S658 20mm metric thread for conduit opening...................................................................................................................................................... M20 25mm metric thread for conduit opening...................................................................................................................................................... M25 3 /4" NPT hub conduit opening........................................................................................................................................................................ NPT75 Furnished with lamps (not installed).............................................................................................................................................................. S714 Pulse-start metal halide only......................................................................................................................................................................... S828 Enclosure machined for 2 conduit/cable entries........................................................................................................................................... S886 Yoke mount and slipfitter............................................................................................................................................................................... SFA6 Photometrics are available online. 1144 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1144-1145.qxp 12/16/2013 7:01 PM Page 1145 Champ® Voyager nR™ Stainless Steel Floodlight Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, AEx nR II, Group IIC IEC Zone 2, Ex nR II ATEX 6L Marine locations Wet locations Photometric Data: MH Wide Beam Reflector HPS Wide Beam Reflector ISOFOOTCANDLE CHART 400W Metal Halide (MH) Catalog Number: SSFMVMY400/MT Lamp: 400W Clear MH Lumen Rating: 34,000 Luminaire located at 0, 0° aiming angle at 45° down from horizontal For 175W MH, multiply footcandles by 0.42. For 250W HPS, multiply footcandles by 0.65. ISOFOOTCANDLE CHART 400W High Pressure Sodium (HPS) Catalog Number: SSFMVSY400/MT Lamp: 400W Clear HPS Lumen Rating: 50,000 Luminaire located at 0, 0° aiming angle at 45° down from horizontal For 150W HPS, multiply footcandles by 0.32. For 250W HPS, multiply footcandles by 0.57. Footcandle Values for Isofootcandle Lines A B C D E F 10' 15' 20' 25' 30' 35' 40' 20.000 8.889 5.000 3.200 2.222 1.633 1.250 4.000 1.778 1.000 0.640 0.444 0.327 0.250 2.000 0.889 0.500 0.320 0.222 0.163 0.125 0.800 0.356 0.200 0.128 0.089 0.065 0.050 0.400 0.178 0.100 0.064 0.044 0.033 0.025 Mounting Height 10' 15' 20' 25' 30' 35' 40' 39.000 3.555 2.000 1.280 0.889 0.653 0.500 6L Mounting Height Footcandle Values for Isofootcandle Lines A B C D E F 40.000 17.778 10.000 6.400 4.444 3.265 2.500 20.000 8.889 5.000 3.200 2.222 1.633 1.250 8.000 3.555 2.000 1.280 0.889 0.653 0.500 4.000 1.778 1.000 0.640 0.444 0.327 0.250 2.000 0.889 0.500 0.320 0.222 0.163 0.125 0.800 0.356 0.200 0.128 0.089 0.065 0.050 Photometrics are available online. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1145 1146-1147.qxp 12/16/2013 6L 7:01 PM Page 1146 Champ® FMV LED Series Floodlight Fixtures • “No lights out” feature – if a single LED fails, others will remain lit from other drivers – minimum 50% output maintained • Terminals – 3 x 6 sq. mm. for IEC version The Champ FMV LED Family FMV LED Series Floodlights are designed to provide full-spectrum, crisp, white light. Five versions of the Champ FMV LED are available, providing ideal solutions for a wide range of applications. FMV Model Equivalent MH HID Lamp Energy Savings FMV FMV FMV FMV FMV 100W-150W 150W-175W 175W-250W 250W-400W 400W Up to 62%! 5L 7L 9L 11L 13L Reduce operation and maintenance costs • Easy installation - compact modular fixture attaches onto existing SFA6 and SWB6 • Energy-efficient technology – use up to 1/ 2 the power of standard HID luminaires • Provides up to 60,000 hours rated life – eliminates need for frequent lamp replacement • Contains no mercury or other hazardous substances Applications: 6L • Five lumen outputs allow for installation in numerous mounting heights • Locations requiring continuous and consistent light levels in extreme ambient temperatures • Areas requiring frequent on-and-off of lights • Where flammable vapors, gases, ignitable dusts, fibers or flyings are present; indoors or outdoors • Where extremely corrosive, wet, dusty, hot and/or cold conditions exist • Type 4X, marine, wet locations, and hose-down environments • Indoor and outdoor area lighting in plants, buildings, and parking areas • Manufacturing plants; heavy industrial, chemical, petrochemical or pharmaceutical facilities; platforms; loading docks; outdoor mounted general area lighting Drivers: Model 5L - 13L 90-305 VAC, 50 / 60 Hz; 108-250 VDC 347 VAC Model 480 VAC Model Standard Option 1 Option 2 UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III Champ FMV LED Benefits: Enhance safety and productivity • Instant illumination and restrike • Better visibility with crisp, white light • Minimum T4 temperature rating – safely operate in the most hazardous environments and any non-hazardous location • Cold temperature operation / no warm-up required Electrical Ratings: Reliable performance in any environment • Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break – greatly reduces the risk of premature failure • Operating ambient -40°C to 55°C • Dark sky friendly with optional visor Certifications and Compliances: • DesignLights Consortium® approved for select models (refer to Ordering Information for details) NEC and CEC • Class I, Division 2, Groups A, B, C, D • Class I, Zone 2 • Class II, Groups E, F, G • Class III • Simultaneous Presence • Wet Locations, Type 4X, IP66 UL Standards • UL844 • UL1598 Luminaires, UL1598A Marine CSA Standard • CSA C22.2 No. 137 IECEx/ATEX • IECEx UL 11.0054X • Ex nA nR IIC T4 Gc Tamb -30°C to +55°C • Ex nA nR IIC T5 Gc Tamb -30°C to +40°C • Ex tc IIIC T68°C Dc IP66 Tamb -30°C to 40°C • DEMKO 12 ATEX 115535X • Ex II 3 G Ex nA nR IIC T4 Gc Tamb -30°C to +55°C • Ex II 3 G Ex nA nR IIC T5 Gc Tamb -30°C to +40°C • Ex II 3 D Ex tc IIIC T68°C Dc IP66 Tamb -30°C to +40°C • CEPEL Ex-1956/10 FMV 5L FMV 7L Standard Materials: • Housing – copper-free aluminum with Corro-free™ epoxy powder coat • Lens – shatter-resistant glass • Gaskets – silicone • External hardware – stainless steel • Factory-sealed, no external seals required LED System: • High brightness light emitting diode (LED) arrays • Color temperature: 3000K (CRI 82) and 5600K (CRI 65) options available • Advanced heat sink design ensures LED does not exceed manufacturer’s temperature ratings across all specified ambient conditions • LM-80 reports available upon request Options: Description Suffix Fused (only applies to UNV1 model, not available for 347V or 480V; NOT marine or cUL Listed) (NEC version only) . . . . . . . . . . . S658 Two conduit/cable glands of like thread installed . . . . . . . . . . S886 Accessories (Order Separately): Description Bolt-on visor (sold separately) . . . . . . . . . . . . Bolt-on wire guard (sold separately) . . . . . . . . . . . . Floodlight slipfitter (sold separately) . . . . . . . . . . . . Slipfitter wall mount adapter (sold separately) . . . . . . . . . . . . FMV 9L FMV 11L FMV 13L 100-277V 50 / 60 Hz Voltage Range, VAC 347 / 480V 60 Hz Voltage Range, VDC 108-250 108-250 108-250 108-250 108-250 Input Power (Nom.) 64 89 121 149 179 Input Amps (Max.) 0.550 0.800 1.083 1.608 1.608 Power Factor >0.85 >0.85 >0.85 >0.85 >0.85 1146 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business Cat. No. DSV1 P61 SFA6 SWB6 1146-1147.qxp 12/16/2013 7:01 PM Page 1147 Champ® FMV LED Series Floodlight Fixtures Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 Safe, reliable heat transfer Installation and replacement made simple The heat sink was designed to perform in high ambient temperatures up to +55ºC and as low as -40ºC. The thick walls of the castings make for a tough, rugged housing that keeps the internal driver and LED temperatures down, allowing them to perform flawlessly, and protects them from damage. Separated driver and LED housing allows dust to shed from fixture. The full-frame yoke was designed to utilize the SFA6 slipfitter and SWB6 wall mount bracket (sold separately), making it ideal for retrofit or new installations. The modular design of the FMV LED allows for easy driver or LED replacement, and allows for the addition of the optional visor or guard in the field. Single cable gland provided with a second plugged cable entry, if an additional cable gland is needed. 6L High efficiency and lumen output High efficiency drivers and LED arrays provide reliable low cost operation in harsh and hazardous environments. Components were chosen to give industry-leading light output from an LED flood. Replaceable drivers and LEDs for ease of maintenance and “no lights out” feature. 6L Versatile design Suitable for hazardous location use in gas or dust areas. Can be used for outdoor or indoor applications, and for a wide range of mounting heights depending on model and light level requirement. Optics were specifically designed to give the familiar and industry-accepted butterfly beam light pattern. www.crouse-hinds.com Optional equipment Cool (C) and Warm (W) white color temperatures available. Optional visor offered (sold separately) to control light spill. Optional wire guard offered (sold separately) to protect lens from damage. Other options available - consult part numbering guide. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1147 1148-1149.qxp 12/16/2013 6L 7:43 PM Page 1148 Champ® FMV LED Series Floodlight Fixtures Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 Catalog Numbering System: SERIES LIGHT SOURCE COLOR MOUNT VOLTAGE OPTICAL DISTRIBUTION SUFFIXES FMV 9L C Y /UNV1 76 S658 SERIES FMV NFMV NEC version with Class/Division ratings IEC version with Class/Zone ratings LIGHT SOURCE / INTENSITY 5L 7L 9L 11L 13L 100W - 150W equivalent 150W - 175W equivalent 175W - 250W equivalent 250W - 400W equivalent 400W equivalent COLOR TEMPERATURE C W 5600K (cool white) 3000K (warm white) MOUNT Y Yoke VOLTAGE /UNV1 /120 /347 /480 100 VAC to 277 VAC 50/60 Hz, 108 VDC to 250 VDC 120 VAC 50/60 Hz** 347 VAC 60 Hz 480 VAC 60 Hz OPTICAL DISTRIBUTION 76 Floodlight pattern optics included ADDITIONAL ITEMS (SOLD SEPARATELY) 6L SUFFIXES M20 M25 S658 S886 DSV1 P61 SFA6 SWB6 20mm metric threads for conduit opening (NFMV only)* 25mm metric threads for conduit opening (NFMV only)* Fused; for UNV1 only; not for marine or cUL Two conduit/cable glands of like thread installed DSV dark sky visor Wire guard factory installed Floodlight slipfitter Slipfitter wall mount adapter *Required for NFMV. Please specify conduit entry. **5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton’s Crouse-Hinds standard Terms and Conditions. DesignLights Consortium® approved models. Cool white only. Dimensions: [532.9] 21.0 [167.1] 6.6 [552.5] 21.75 [405.9] 16.0 [120.7] 4.75 1148 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business [14] Ø.55 1148-1149.qxp 12/16/2013 7:43 PM Page 1149 Champ® FMV LED Series Floodlight Fixtures Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2 Cl. II, Groups E, F, G Cl. III UL Listed & CSA Certified IECEx / ATEX Simultaneous Presence Wet Location, Type 4X, IP66 6L Photometric Data: FMV 13L @ 40 Ft. High; Tilt Angle = 45 Degrees (Isofootcandles) Point By Point FC Readings Distance in Feet .35 Fc .5 Fc 1 Fc 2 Fc 2.5 Fc MULTIPLIERS FOR OTHER LED FLOODLIGHTS Luminaire Series Wattage Lumens* FMV 5L 64 4386 FMV 7L 89 6720 FMV 9L 121 8478 FMV 11L 149 10420 *FMV 13L output is 12,940. 6L Weights: Model Lbs. Kg. 5L 7L 9L 11L 13L 39.11 39.16 39.73 40.35 40.35 17.74 17.76 18.02 18.30 18.30 Ambient Temperature: FMV 5L FMV 7L FMV 9L FMV 11L FMV 13L Max. Temp. ºC Cl. I, Div. 2 Cl. I, Zone 2 Simu. Presence Div. 1 and Div. 2 Cl. II, Div. 1 Cl. III 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - 40 T3C T5 T3A T5 T5 55 T3C T4 - - - www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1149 1150-1151.qxp 12/16/2013 6L 7:01 PM Page 1150 Champ® F2MV Mini-Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Marine locations NEMA Type 4X Wet locations F2MV is a compact floodlight consisting of a Corro-Free™ epoxy coated copper-free aluminum enclosure, with stainless steel external hardware and impact-resistant glass. It is available for use with the following energy-saving mogul base HID lamp types and wattages: • High Pressure Sodium (HPS)—50, 70, 100, and 150W • Metal Halide (MH)—70, 100, and 175W Applications: Available in a variety of voltage ratings, this compact floodlight is suitable for marine and wet locations. 6L Features and Benefits: • Small, compact size—easy to install and maintain • 40°C, 55°C, and 65°C ambient suitability—addresses high ambients common in industrial facilities • Low ambient capability to –40°C—perfect for colder climates • Heavy-duty, copper-free aluminum enclosure with epoxy coating and stainless steel hardware—provides a robust design with industrial grade construction and corrosion resistance • Continuous silicone gasketing—ensures wet and marine locations integrity • Stainless steel tether chain and captive cover screws—secure cover to housing ensures ease of maintenance • Trunnion (yoke) mount design—standard construction provides the greatest mounting flexibility, can be mounted vertically (wall), horizontally (rooftop or floor), or any angle in between • Requires only two bolts to mount—simplifies installation • Heat- and impact-resistant tempered glass lens—provides exceptional stability • Shock-absorbing mogul base lamp socket—cushions lamp, improves lamp life in harsh environments • 3-axis resonance withstand and UL844 vibration compliant— stands up to the tough jobs • Precision formed aluminum reflector—superior beam control, distribution and efficiency • NEMA 7x6 floodlight pattern with lamp orientation base down—the ideal light distribution for industrial applications • Multi-tap ballasts—offering a choice of 120, 208, 240, and 277V; 220V, 50Hz; 240V 50Hz; Tri-Tap (120, 277, and 347) and 480V ballasts are also available • High light output with a low cost of operation—a cost-effective, high wattage floodlight • For use with SFA6 slipfitter adapter and SWB6 wall mount bracket accessories—further enhances mounting flexibility • Restricted breathing compliance—cooler T-numbers for increased hazardous locations suitability Standard Materials: • • • • • • Enclosure (housing and lens cover)—copper-free aluminum Cover chain and external hardware—stainless steel Lens—heat- and impact-resistant glass Gaskets—silicone rubber Yoke—copper-free aluminum Reflector—diffused aluminum lighting sheet Certifications & Compliances: NEC/CEC: • Class I, Division 2, Groups A, B, C, D • Marine locations • NEMA Type 4X • Wet locations IEC/NEC/CEC: • Class I, Zone 2, Group IIC • With suffix—S826 and S826TB—restricted breathing (Ex nR) option • Class I, Zone 2 • Class I, Division 2 UL Standards: • 844—Hazardous (Divisions Classified) Locations • 2279—Hazardous (Zones Classified) Locations • 1572—Ordinary and Wet Locations, Marine Outside Type CSA Standards: • C22.2 No. 137 • CAN/CSA-E79 Series IEC Standards: • 60079-15 Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) • HPS—50, 70, 100, and 150W • MH—70, 100, and 175W Voltages: Standard Voltage Ballasts • Multi-tap (120, 208, 240, and 277V 60Hz) • Dual-tap (120, 277V 60Hz)—50W HPS only • 480V 60Hz • Tri-tap (120, 277, 347V 60Hz) Optional Voltage Ballasts (Consult Eaton's Crouse-Hinds) • 220V or 240V 50Hz (for export) • 220V 60Hz (for export) Isolated Ballasts (Consult Eaton's Crouse-Hinds) • 208, 240, or 480V (for Canada) Standard Finishes: • Enclosure and yoke—Corro-Free™ epoxy powder coat • Stainless steel—natural 1150 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Hub Size: • Standard—(2) 3/4" NPT • Optional—(2) 25 mm (M25 x 1.5) or (2) 20 mm (M20 x 1.5) Copyright© 2013 Eaton’s Crouse-Hinds Business 1150-1151.qxp 12/16/2013 7:01 PM Page 1151 Champ® F2MV Mini-Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Marine locations NEMA Type 4X Wet locations 6L Ordering Information: Base Catalog Number* Lamp Type High Pressure Sodium Metal Halide Watts 3 /4" NPT Hub 25mm Hub† 50 70 100 150 70 100 175 F2MVSY050__ F2MVSY070__ F2MVSY100__ F2MVSY150__ F2MVMY070__ F2MVMY100__ F2MVMY175__ F2MVS25Y050__ F2MVS25Y070__ F2MVS25Y100__ F2MVS25Y150__ F2MVM25Y070__ F2MVM25Y100__ F2MVM25Y175__ * To complete catalog number, add voltage and options suffix(es). †For 20mm metric threads, change 25 to 20 in catalog number. Example: F2MVS20Y050/MT. Voltage Suffixes: Voltage (60Hz) Dual-Tap Tri-Tap Multi-Tap 480 Suffix /DT /TT /MT /480 Options F2MVSY070/MT V2PC20 Example: Series Yoke Lamp Type Voltage Watt Photocell Options: Photometrics are available online. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1151 6L Description Suffix Instant Restrike and Ballast Guard Instant Restrike—enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage Ballast guard starter cut out switch—prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life TIR • 150W LX HPS only................................................................................................................................................................................... Factory assembled with HID lamp installed................................................................................................................................................ FA Fused (not suitable for marine applications)................................................................................................................................................ S658 Furnished with lamps (not installed)............................................................................................................................................................ S714 Pulse-start metal halide only....................................................................................................................................................................... S828 Photocell 120V, 50/60Hz installed............................................................................................................................................................... V2PC20 Photocell 208-240V, 50/60Hz installed........................................................................................................................................................ V2PC22 Photocell 277V, 50/60Hz installed............................................................................................................................................................... V2PC27 1152-1153.qxp 12/16/2013 6L 7:01 PM Page 1152 Champ® F2MV Mini-Floodlights Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Marine locations NEMA Type 4X Wet locations Photometric Data: Isofootcandle Chart F2MV 150W High Pressure Sodium (HPS) Catalog Number: F2MVSY150 Lamp: 150W Clear HPS Lumen Rating: 16,000 For 100W HPS, multiply footcandles by .55. For 70W HPS, multiply footcandles by .40. For 50W HPS, multiply footcandles by .24. Isofootcandle Chart F2MV 175W Metal Halide (MH) Catalog Number: F2MVMY175 Lamp: 175W Clear MH Lumen Rating: 14,000 For 100W MH, multiply footcandles by .58. For 70W MH, multiply footcandles by .37. Accessories (Order Separately): Slipfitter adapter To be mounted to yoke mount fixture Fits onto 2" pipe/conduit.......................................................................... Wall bracket Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability........................ SFA6 SWB6 Effective Projected Area (EPA): • For windloading • For proper pole selection Aiming Angle EPA 0° 30° 60° 1.6 FT2 1.6 FT2 1.1 FT2 6L Footcandle Table: Footcandle Values for Isofootcandle Lines Mounting Height 10' 15' 20' 25' 30' A B C D E 8.00 3.56 2.00 1.28 0.89 4.00 1.78 1.00 0.64 0.44 2.00 0.89 0.50 0.32 0.22 0.80 0.36 0.20 0.13 0.09 0.40 0.18 0.10 0.06 0.04 Photometrics are available online. 1152 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1152-1153.qxp 12/16/2013 7:01 PM Page 1153 Cl. I, Div. 2, Groups A,B,C,D Cl. I, Zone 2, Group IIC Champ® F2MV Mini-Floodlights Marine locations NEMA Type 4X Wet locations 6L Temperature Performance Data: Lamp Catalog Series Type F2MVS High Pressure Sodium F2MVM Metal Halide 40°C Ambient 55°C Ambient 65°C Ambient Temperature Code Temperature Code Temperature Code Fixture Aiming Class I, Watts Zone 2 Class I, Div. 2 Supply Wire °C Class I, Zone 2* Class I, Div. 2 Supply Wire °C Class I, Zone 2* Class I, Div. 2 Supply Wire °C Range Figure 50 70 100 150** 70 100 175** T3C T3A T2D T2A T3C T2D T2A 75 60 75 75 75 75 75 T6 T5 T4 T4 T5 T4 T3 T3C T3A T2C T2A T3A T2D T2A 75 75 90 85 75 75 85 T3B T3 – T3 T4 T4 T3 T5 T4 – T2A T3A T2C T2A 75 85 – 110 85 85 110 90° 90° 90° 90° 90° 90° 90° T6 T6 T4 T4 T6 T4 T3 1 1 1 1 1 1 1 *Restricted breathing explosion protection, requires suffix S826 (TB). **Suitable for use in 65°C ambient without optional fuses. Lamp Selection (Mogul Base): Fixture Watts Type Bulb F2MVSY050 F2MVSY070 F2MVSY100 F2MVSY150 F2MVMY070 F2MVMY100 F2MVMY175 50 HPS 70 HPS 100 HPS 150 HPS 70 MH 100 MH 175 MH ED23 ED23 ED23 ED23 ED28 ED28 ED28 /2 /2 /2 1 /2 1 1 1 or or or or ET23 ET23 ET23 ET23 or BT28 /2 /2 /2 1 /2 1 1 1 G.E. Osram Philips Venture LU50 LU70 LU100 LU150/55 – – MVR175/C/U LU50 LU70 LU100 LU150/55 – – M175/C/U C50S68 C70S62 C100S54 C150S55 – – MH175/C/U – – – – MH70W/U/ED28 MH100/U/ED28 MH175/C/U Weights and Dimensions: Fixture Weight: 26 lbs. 6L Photometrics are available online. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1153 1154-1155.qxp 6L 12/16/2013 7:02 PM Page 1154 FZD Series Floodlight Luminaire Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone 1 Marine Locations Wet Locations, IP66 Finally, a true floodlight luminaire for hazardous areas. Eaton's Crouse-Hinds FZD Series Luminaires are the first to deliver NEMA 7 x 6 floodlight distribution patterns for Class I, Division 1 and Zone 1 environments. That means you’ll need fewer of them to illuminate a given area. With their labor-saving features and flexible mounting options, the FZD Series is ideal for: • Heavy process industries where flammable or explosive vapors or gases are present • Hazardous areas, both indoors and outdoors, including those requiring elevated ambient capability, where long life and low maintenance costs are desired • Petroleum refineries, chemical, petrochemical, and other heavy process industrial facilities • Mounting to a wall, structure, or pole (with pole mount adapter accessory) 6L Features and Benefits: • NEMA 7 × 6 floodlight distribution pattern is standard – ideal light distribution for industrial applications; requires fewer luminaires in general lighting applications than required when using general area luminaires with high bay reflectors • Internal reflector – available in wide and narrow beam options; enclosed in glass tube, reducing maintenance and enhancing light output • Heavy duty, cast copper-free aluminum construction with epoxy powder coat finish and stainless steel hardware – provides long life in industrial, abusive environments • Explosionproof threaded construction – suitable for hazardous and industrial applications; easy to maintain with no bolted covers • O-ring gaskets on all threaded openings – allow NEMA Type 4X and marine listing for the harshest outdoor environments • 40°C, 55°C, and 65°C ambient suitability – ideal for use in high ambient temperature areas common in industrial facilities • Factory-sealed ballast housing – keeps ballast isolated from wiring chamber • Trunnion (yoke) mount design – standard construction provides the greatest mounting flexibility; can be vertically (wall) or horizontally (rooftop or floor) mounted • Simple installation – requires only two bolts to mount • Mounting flexibility – pole mount with SFA6-XP pole mount adapter (shown below) or wall or ceiling mount with FZD-KIT1 mounting accessory kit (shown above) FZD with separate ballast enclosure Certifications and Compliances: NEC/CEC • Class I, Division 1, Group B (with suffix GB*), C, D • Class I, Zone 1, Group IIB+H2 (with suffix -GB*), IIB • AEx d IIB+H (with suffix -GB*), IIB • Ex d IIB+H2 (with suffix -GB*), IIB • Marine Locations • Wet Locations • Enclosure Type 4X • IP66 • UL Listed (UL Standards 844, 1598, 1598A, 2279) • cUL Listed (certified by UL to CSA Standard C22.2 No. 137 and CAN/CSAE60079-1) *See options for Group B and IIB+H2 ordering information. Standard Materials: • Luminaire housing, covers, socket holder, lamp tube end rings – copperfree aluminum • External hardware – stainless steel • Glass lamp tube – heat- and impactresistant tempered glass • O-ring gaskets – neoprene/silicone • Yoke – aluminum • Trunnion adapter – brass Standard Finishes: Pole Mount Adapter Ratings: Sources/Wattages (Mogul Base Lamps) • HPS – 150, 250 & 400 watts • MH – 175, 250 & 400 watts Voltages Standard Voltage Ballasts • Multi-tap (120, 208, 240 & 277 V, 60 Hz) • 120 V, 60 Hz • 480 V, 60 Hz • Tri-tap (120, 277 & 347 V, 60 Hz) Optional Voltage Ballasts • 220 V, 60 Hz • 220 V, 50 Hz Hub Size • Standard: Two 3/4" NPT entries • Optional: Two 25 mm (M25) entries (consult Eaton's Crouse-Hinds) Dimensions (In Inches): • Aluminum – Corro-free™ epoxy powder coat • Stainless steel – natural • Brass – natural Luminaire Weights (lbs.): Luminaire FZDS (HPS) FZDM (MH) 150 watt 72 75 175 to 250 watt 77 77 400 watt 80 80 1154 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1154-1155.qxp 12/16/2013 7:02 PM Page 1155 Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone 1 Marine Locations Wet Locations, IP66 FZD Series Floodlight Luminaire Ordering Information: Lamp Type Wide Beam Reflector – 7 x 6 Distribution Voltage Suffixes: Watts Cat. #* Yoke Mount With 3 / 4" NPT Hubs Standard Voltages High Pressure Sodium 150† 250 400 FZDS2NY150W/MT FZDS2NY250W/MT FZDS2NY400W/MT Metal Halide 175 250 400 FZDM2NY175W/MT FZDM2NY250W/MT FZDM2NY400W/MT Pulse Start Metal Halide 175 250 400 FZDM2NY175W/MT S828 FZDM2NY250W/MT S828 FZDM2NY400W/MT S828 High Pressure Sodium 150† 250 400 FZDS2NY150N/MT FZDS2NY250N/MT FZDS2NY400N/MT Metal Halide 175 250 400 FZDM2NY175N/MT FZDM2NY250N/MT FZDM2NY400N/MT Pulse Start Metal Halide 175 250 400 FZDM2NY175N/MT S828 FZDM2NY250N/MT S828 FZDM2NY400N/MT S828 Narrow Beam Reflector – Spotlight Distribution To complete the catalog number, add option suffix(es) if desired. Example: FZDS2NY400W/MT-S658 *All FZD catalog numbers shown above are with multi-tap ballasts (120, 208, 240 & 277 V, 60 Hz). The "MT" in the catalog number may be changed to any of the voltage suffixes listed below. †150 watt HPS luminaires are furnished with ANSI spec/S55 ballasts for 55 V lamps. FZD With Separate Ballast Enclosure: Glass Fiber Reinforced Polyester Ballast Enclosure With Cable Entry Narrow Beam Reflector HPS/MH Metal Halide High Pressure Sodium T-Code Cat. # x 6 Distribution T4 NOR 000 005 192 506 T3 NOR 000 005 194 106 T3 NOR 000 005 194 006 – Spotlight Distribution 250 T4 NOR 000 005 192 505 400 T3 NOR 000 005 194 105 400 T3 NOR 000 005 194 005 Multi-tap (120, 208, 240, 277 V, 60 Hz) Tri-tap (120, 277, 347 V, 60 Hz) 120 V, 60 Hz 480 V, 60 Hz Narrow Beam Reflector HPS/MH Metal Halide High Pressure Sodium – Spotlight Distribution 250 T4 NOR 000 005 192 501 400 T3 NOR 000 005 194 101 400 T3 NOR 000 005 194 001 www.crouse-hinds.com US: 1-866-764-5454 Suffix /MT 220 V, 50 Hz /220 50 /TT /120 /480 220 V, 60 Hz /220 Description Suffix • Ballast-Gard™ starter cut-out switch prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and igniter life (HPS only; not available with IR option) .................BG • Factory assembled with HID lamp installed for additional labor savings............................................................................FA • Factory certified: Class I, Division 1, Group B and Class I, Zone 1, Group IIB + H2 ...........................................................GB • Instant restrike enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage; it has no affect on the warmup period of cold lamps; available for use with 150 watt HPS only ..................................................................................IR • Fusing protects ballast and capacitor against abnormal line conditions (not suitable for marine applications).....................S658* *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Accessories: (order separately) For Pole Mounting Cat. # Pole mount adapter • Class I, Division 1, Groups B, C, D • Attach to yoke; fits 2" NPT conduit pole Flexible explosionproof coupling Elbow fitting For Wall Or Ceiling Mounting Kit includes: EABC26-SA conduit outlet box, ECLK236 flexible explosionproof coupling, and EL296-SA elbow fitting SFA6-XP ECLK236 EL296-SA FZD-KIT1 Temperature Performance Data: Ambient Temp. °C Class I, Division 1, Zone 1 Supply Wire °C 150 watt HPS 40 55 65 T3C T3C T3B 75 75 90 250 watt HPS 40 55 65 T3C T3C T3B 75 75 90 400 watt HPS 40 55 65 T3C T3C T3B 75 75 90 175 watt Metal Halide 40 55 65 T3A T3 T3 75 75 90 250 watt Metal Halide 40 55 65 T3A T3 T3 75 75 90 400 watt Metal Halide 40 55 65 T3A T3 T3 75 75 90 Lamp Cat. # NOR 000 005 192 502 NOR 000 005 194 102 NOR 000 005 194 002 Optional Voltages Options: Stainless Steel Ballast Enclosure With Cable Entry Lamp Type Watts T-Code Wide Beam Reflector – 7 x 6 Distribution HPS/MH 250 T4 Metal Halide 400 T3 High Pressure Sodium 400 T3 Suffix CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1155 6L Lamp Type Watts Wide Beam Reflector – NEMA 7 HPS/MH 250 Metal Halide 400 High Pressure Sodium 400 6L 1156-1157.qxp 12/16/2013 7:02 PM Page 1156 FZD Series Floodlight Luminaire 6L Photometric Data Photometrics: Note: There are no aiming angle limitations for the FZD. The only limitations are those encountered by interference of the trunnion arm. The trunnion arm may be mounted on vertical or horizontal surfaces to overcome any limitations. HPS Narrow Beam Reflector HPS Wide Beam Reflector Isofootcandle Chart Isofootcandle Chart FZD 400W High Pressure Sodium (HPS) Catalog Number FZDS2NY400N Lamp: 400 W Clear HPS Lumen rating: 50,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 150W HPS, multiply footcandles by 0.32. For 250 W HPS, multiply footcandles by 0.6. FZD 400W High Pressure Sodium (HPS) Catalog Number FZDS2NY400W Lamp: 400W Clear HPS Lumen rating: 50,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 150W HPS, multiply footcandles by 0.32. For 250W HPS, multiply footcandles by 0.6. Footcandle Values For Isofootcandle Lines Mtg. Ht. 10' 12' 16' 20' 25' Footcandle Values For Isofootcandle Lines A B C D E F G 200.00 138.89 78.13 50.00 32.00 100.00 69.44 39.06 25.00 16.00 50.00 34.72 19.53 12.50 8.00 20.00 13.89 7.81 5.00 3.20 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.8 2.00 1.39 0.78 0.50 0.32 Mtg. Ht. 6L MH Narrow Beam Reflector 10' 12' 16' 20' 25' A 100.00 64.99 39.06 25.00 16.00 A B C D E F 20.00 13.89 7.81 5.00 3.20 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 MH Wide Beam Reflector Isofootcandle Chart Isofootcandle Chart FZD 400W Metal Halide (MH) Catalog Number FZDM2NY400N Lamp: 400W Clear MH Lumen rating: 34,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 175W MH, multiply footcandles by 0.38. For 250W MH, multiply footcandles by 0.6. FZD 400W Metal Halide (MH) Catalog Number FZDM2NY400W Lamp: 400W Clear MH Lumen rating: 34,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 175W MH, multiply footcandles by 0.38. For 250W MH, multiply footcandles by 0.6. Footcandle Values For Isofootcandle Lines Mtg. Ht. 10' 12' 16' 20' 25' Footcandle Values For Isofootcandle Lines B C D E F G 50.00 34.72 19.53 12.50 8.00 20.00 13.89 7.81 5.00 3.20 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 Mtg. Ht. 10' 12' 16' 20' 25' A B C D E F 20.00 13.89 7.81 5.00 3.20 10.00 6.49 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 Effective Projected Area (EPA): • For windloading • For proper pole selection Aiming Angle 0° 45° 1156 www.crouse-hinds.com EPA 1.8 ft2 2.3 ft2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1156-1157.qxp 12/16/2013 7:02 PM Page 1157 Hazard•Gard® H.I.D. Floodlights Cl. I, Div. 1 & 2, Groups C, D Cl. I, Div. 1 & 2, Groups B, C, D (add suffix GB) Cl. I, Zone 1 Marine Locations, IP66 Wet Locations Factory-sealed Applications: Standard Materials: Hazard•Gard Luminaires with Trunnion Arm (S812 suffix) and EV912 High Bay Reflector are used in: • Heavy process industries where flammable or explosive vapors or gases are present • Hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired • Petroleum refineries, chemical, petrochemical, and other heavy process industry facilities • Hazardous locations requiring elevated ambient capability • For mounting to a wall or structure • Mounted on a pole, when used with the SFA6 slipfitter adapter • Mounting module, cover, ballast housing, guard, globe ring – copper-free aluminum • Globe – heat- and impact-resistant glass • Exterior hardware – stainless steel • Lamp socket – porcelain with stainless steel screw shell • Reflector – high bay: Alzak aluminum Features: Certifications and Compliances: • NEC/CEC: Class I, Division 1 and 2, Groups B (with GB suffix), C, D • UL Standard: 844, 595 • CSA Standard: C22.2 No. 137 Standard Finishes: • Copper-free aluminum – epoxy powder coat • Alzak – natural (anodized) Temperature Performance Data: Options: Description Suffix Fused.................................................. S658 Not suitable for marine applications Ballast-Gard™.................................... BG 50-400 HPS only Instant Restrike .................................. IR Cannot be used with BG or QTZ options 50-150W LX HPS only Quartz Auxiliary Lighting .................... QTZ Not available with 400W MH Uses 100 watt single-ended lamp Lamp not included Group B Suitability ............................. GB Size Ranges: • 3/4" Electrical Rating Ranges: • 120, 208, 240, 277, 347, 480, 600, multi-tap* • 50 to 400 watts Hazard•Gard Luminaire with Trunnion Arm (S812 suffix) Maximum Ambient Class I Watts 40°C 55°C High Pressure Sodium 50 T4 T4 70 T4 T4 100 T4 T4 150 T4 T4 200 T3A — 250 T3A — 400 T3A — Metal Halide 70 T3 100 T3 175 T3 250 T3 400 T2D T3 T3 T3 T3 — 65°C T3C T3C T3C T3C — — — — — — — — Note: See Section 4L for additional luminaire information. Required Accessories: 6L • Luminaire is factory wired; power is fed through "wireless" connection block which serves as a mechanical seal between conduit and ballast compartments, eliminating the need for an external, field-installed seal; the result is fast, easy installation • High bay reflectors of Alzak® aluminum • Internally fluted glass globes reduce glare and provide comfortable viewing light • Wide range of light sources and wattages to meet specific lighting needs – 50, 70, 100, 150, 200, 250 and 400W high pressure sodium (HPS); 70, 100, 175, 250 and 400W metal halide (MH) • High power factor (90%+) ballasts reduce power costs – allow more luminaires per circuit • Elevated ambient capability permits reliable operation at high ambient temperature; selected luminaires are suitable for ambient temperatures up to 65°C • Integral ballasts – separate ballasts are not required; lowest installed cost • Factory-sealed, porcelain, mogul base socket • The trunnion arm gives you the ability to offer a Hazard•Gard floodlight with varying degrees of adjustability between -90° and +90° • When mounting on a wall, there are numerous mounting arrangements – due to the pre-drilled openings in the wall bracket 6L Ordering Information Catalog number includes guard, trunnion arm, and high bay reflector Hub Luminaire Size Cat. # Watts (In.) High Pressure Sodium 3 EVMA42051/volts S812 EV3912 50 /4 3 EVMA42071/volts S812 EV3912 70 /4 3 EVMA42101/volts S812 EV3912 100 /4 3 EVMA42151/volts S812 EV3912 150 /4 3 EVMA42201/volts S812 EV3912 /4 3 EVMA42251/volts S812 EV3912 /4 3 EVMA42401/volts S812 EV3912 /4 UNL Metal Halide 90° Angle EVMA92071/volts EVMA92101/volts EVMA92171/volts EVMA92251/volts EVMA92401/volts Note: S812 S812 S812 S812 S812 EV3912 EV3912 EV3912 EV3912 EV3912 70 100 175 250 400 /4 3 /4 3 /4 3 /4 3 /4 3 Replace "volts" with Suffix from Voltage Suffix Table below EABC Cat. # Hub Size (In.) EABC26 3 /4 Cat. # Size UNL205 3 /4 to 3/4 ECGJH Cat. # Flexible Length ECGJH230 30 Size /4 3 *CSA certified luminaires are not available with multi-tap ballast or S658 fuse option. Alzak is a registered trademark of ALCOA. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1157 1158-1159.qxp 12/16/2013 6L 7:02 PM Page 1158 Cl. I, Div. 1 and 2, Groups C, D Cl. I, Zone 1 RCDE Series Incandescent Floodlights Applications: RCDE Incandescent Lighting Luminaires are permanently installed to provide general illumination in locations having hazardous atmospheres, such as: • Oil refineries • Oil and gasoline loading docks • Aircraft servicing docks and shelters • Distilleries • Paint manufacturing plants • Pumping stations • Other Class I, Groups C and D locations Features: 6L RCDE Incandescent Lighting Luminaires have fixed mountings as follows: • RCDE-6 – junction box base with four mounting feet or 2" threaded hub (fill sealing chamber with Chico® A after conductors are in place) • RCDE-6 adjustment allows rotation of 360° horizontally and 75° vertically • Locking screws hold housing firmly in position • RCDE-10 – junction box base with four mounting feet • Door which threads into housing includes heat- and impact-resistant lens; door has notches or holes provided for ease of removing or tightening • Factory wired leads through explosionproof seal to junction box • Adjustment that allows rotation of 360° horizontally and 135° vertically; locking bolts or clamps hold housing firmly in position Certifications and Compliances: • NEC/CEC: RCDE – Class I, Division 1 and 2, Groups C, D; Class I, Zone 1 (see photometric data listing) • UL Standard: 844 • CSA Standard: C22.2 No. 137 (RCDE6 only) CEC/CSA Certified RCDE-6 - Eaton's Crouse-Hinds Canada luminaires only. Standard Materials: • Body – copper-free aluminum • Lens – glass-, heat- and impact-resistant RCDE-6 Standard Finishes: Junction box base 44978A (2" threaded hub) Junction box base (4 mtg. feet) 44719B • Natural Description Size Ranges: • RCDE – fixed mounting – 3/ 4" hubs Capacity Ranges: • RCDE-6 – 150 watt, PAR38 or R40; 300 watt, R40 (medium base) • RCDE-10 – 500 watt, PAR64 Ext. Mog End Prong Ordering Information: After identifying the hazardous area, select the model of lighting luminaire required for that area. Then from the photometric data, select appropriate Cat. No. based on type of mounting desired (Example: RCDE-10 No. 47282). Temperature Performance Data: RCDE-10 Description Cat. # Junction box base (4 mtg. feet) 47282A (based on 40°C Ambient) RCDE-6 RCDE-10 1158 150W 300W T3B T2B 500W T3C www.crouse-hinds.com US: 1-866-764-5454 Cat. # CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1158-1159.qxp 12/16/2013 7:02 PM Page 1159 RCDE Series 6L Dimensions & Weights Photometric Data Cl. I, Div. 1 and 2, Group D Explosionproof Incandescent Floodlights Dimensions (In.): RCDE-10 RCDE-6 Fixture Weights: Cat. # RCDE-6 44719B 44978A RCDE-10 47282A Lbs. (Net) 21.0 21.0 26.0 Photometric Data: Beam Spread Lamp Watts and Type RCDE-6 150 Watt PAR38 Flood 300 Watt* R40 Flood 300 Watt R40 Spot RCDE-10 500 Watt, PAR64 (500 PAR64/NSP) 500 Watt, PAR64 (500 PAR64/MFL) Class I, Groups C, D Class I, Group D Class I, Group D Hor. Vert. Beam Lumens Av. Max. Candle Power 60° 60° 1690 4000 28° 28° 1200 11500 123° 123° 3200 1950 60° 60° 3100 8900 19° 14° 3000 110000 35° 19° 3300 37000 55° 32° 3400 13000 6L 150 Watt PAR38 Spot Location 500 Watt, PAR64 (500 PAR64/WFL) *CSA certified fixtures are for 150 watt lamp maximum. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1159 1160-1161.qxp 12/16/2013 7:03 PM Page 1160 6L 6L 1160 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1160-1161.qxp 12/16/2013 7:03 PM Page 1161 Lighting Accessories Hazardous and Non-hazardous 7L Description Page No. Application/Selection see page 1162 Hazardous Area Hangers Adjustable Type UNR see page 1179 Flexible Type EC Series see page 1173 Locking Coupling COUP Series see page 1179 Outlet Box Type EAHC/EFHC Series GUA/GUF Series CPS Series see page 1174 see page 1178 see page 1176 Outlet Box Type with Flexible Cushion EFHX Series see page 1175 Non-hazardous Area Fittings Conduit Clamps CHS Series see page 1171 Non-hazardous Area Hangers – Flexible Type Ball and Cushion ARB Series UNJ/UNJC Series see page 1169 see page 1167 Cushion – Vaportight AHG Series UNHC Series see page 1167 see page 1171 Hooks and Loops UNE, UNH, UNHC Series see page 1170 AL Series see page 1166 Quick Disconnect Type FHM Series www.crouse-hinds.com US: 1-866-764-5454 see page 1172 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1161 7L Outlet Box – Ball and Cushion 1162-1163.qxp 7L 12/16/2013 7:03 PM Page 1162 Luminaire Hangers and Accessories – For Pendant Mount Application and Selection Applications: Typical Luminaire Weights: • Luminaire hangers listed in this section are used for pendant suspension of incandescent, high intensity discharge, and fluorescent industrial luminaires • They are especially suitable for use in locations where moisture, dust, and corrosion are a problem Luminaire Weight Type (lbs.) Incandescent: VAPORGARD™ Series VDA12 11/2 VDA12G 4 VDA12GP 41/4 VDA15 11/4 VDA15G 3 VDA15GP 31/4 VDA23 11/2 VDA23G 4 V Series V275 23/4 V2759 41/4 EV Series EVI301 11 EVI501 24 EVA292 18 Corro•Gard® Series NDA32 51/2 NDA32G 71/2 NDA33 NDA33G 81/4 7L Hangers for Non-hazardous Locations: • Hangers listed provide a wide variety of mounting means; luminaires may be suspended from cast outlet boxes, stamped steel outlet boxes, or directly from the conduit system; also offered are several styles of hook type hangers, used to suspend luminaires by means of conduit stems or support rods from span wires, horizontal conduit and luminaire loops • All hangers are flexible, permitting luminaire and supporting stem to swing freely; this feature permits luminaires to hang plumb and prevents damage to the luminaire, stem, and outlet box in case of high wind or accidental impact • Hangers are constructed so that luminaires cannot be rotated, thereby eliminating wire twisting and possible damage to connections • Cushion hangers, listed for most styles, include a spring which carries the weight of the luminaire; this feature prolongs lamp life and protects the luminaire assembly from shock or vibration • All hangers are easily installed; with many, the luminaire, stem, and support member can be assembled and wired at the work bench before making the final installation; with several, a quick disconnect plug and receptacle feature is either provided or can be easily arranged, to facilitate luminaire installation and removal for maintenance Luminaire Type H.I.D.: Champ® Series DMVC2A250GP DMVM2A175GP DMVM2A250GP DMVS2A070GP DMVS2A100GP DMVS2A150GP LMVS2A035GP LMVS2A050GP LMVS2A070GP LMVS2A100GP VMVM2A175GP VMVM2A250GP VMVM2A250GR305 VMVM2A250GRD4 VMVM2A400GR305 VMVM2A400GRD4 VMVS2A050GP VMVS2A070GP VMVS2A100GP VMVS2A150GP VMVS2A200GP VMVS2A200GR305 VMVS2A200GRD4 VMVS2A250GP VMVS2A250GR305 VMVS2A250GRD4 VMVS2A400GP VMVS2A400GRD4 Considerations for Selection: Hangers for Hazardous Locations: Location: • Will it require more stringent corrosion protection material? • Will it be a hazardous or non-hazardous location? Lighting luminaire to be used: • Some hangers can be used with a multitude of luminaires; others are specialized • Weight of luminaire is a consideration in selecting cushion hangers • As required by NEC Article 501 and CEC Part I Section 18, rigid conduit luminaire stems longer than 12" must be permanently and effectively braced or flexibility provided in the form of a fitting or flexible support • A variety of hangers is offered for both rigid conduit suspension and flexible suspension; flexible luminaire hangers listed comply with NEC Article 501 and CEC Part I Section 18 and also permit luminaires to hang plumb 1162 CAN: 1-800-265-0502 www.crouse-hinds.com US: 1-866-764-5454 Weight (lbs.) 313/4 33 333/4 303/4 313/4 34 103/4 113/4 113/4 121/4 171/4 34 37 341/2 38 351/2 151/4 161/4 161/4 161/2 31 34 311/2 31 34 311/2 40 401/2 Copyright© 2013 Eaton’s Crouse-Hinds Business Luminaire Type Hazard-Gard® Series EVMA50W HPS EVMA70W HPS EVMA100W HPS EVMA150W HPS (55V) EVMA150W HPS (100V) EVMA175W MH EVMA200W HPS EVMA250W HPS EVMA250W MH EVMA400W HPS EVMA400W MH Fluorescent: DMVF2A026GP DMVF2A039GP DMVFB2A026GP DMVFB2A039GP EVF22062 EVF24062 EVF22082 FVN4240 FVN4340 FVN4260 NFW4240 VFA222G EVFT (2 Lamp) EVFT (4 Lamp) FVS Reflector/Refractor Type EV3912 RA64, 636 RA70, 71, 739, 725 RD64, 636 RD70, 71, 739, 725 PR2, 3, 5 R2 R5 GRD4 G241 G245 GR305, GR205 Weight (lbs.) 41 41 45 46 45 43 47 47 44 56 52 191/4 221/4 191/2 57 94 52 52 54 58 21 4 191/2 361/2 12 1 11/4 1 1 3 131/2 13 133/4 21/4 21/4 14 1162-1163.qxp 12/16/2013 7:03 PM Page 1163 Luminaire Hangers and Accessories – For Pendant Mount 7L Quick Selector Chart Quick Selector Chart Hanger Type AL Function Outlet box and hanger NEC/CEC Hazardous Area Compliances Cl. I, Div. 2 Use with Luminaire Type Any non-hazardous or Class I, Div. 2 Use with Mtg. Box None needed Quick disconnect between luminaire and outlet box Not applicable Any non-hazardous None needed AHG Gasketed hanger (vaportight) Cl. I, Div. 2; Cl. II, Div. 2; Cl. III Wet locations NEMA 3, 3R Any non-hazardous or Div. 2 luminaires Any UNJ/UNJC Ball and cushion hanger Cl. I, Div. 2 Any non-hazardous or Class I, Div. 2 ARB Ball or cushion hanger Cl. I, Div. 2 UNE, UNH, UNHC Quick disconnect hanger hook EC Luminaire Weight Capacity (Ball or Plain Type) 125 lbs. Standard Material Body – Feraloy® iron alloy Nipple – malleable iron Cover – sheet steel 125 lbs. Body – copperfree aluminum Cover – steel Loop and assembly – copper-free aluminum or steel 4-30 lbs. — Housing – malleable iron and Feraloy iron alloy Stem support – Feraloy iron alloy Any 6-48 lbs. 125 lbs. Body – malleable iron Clamp – copper-free aluminum Any non-hazardous or Class I, Div. 2 GRF 4-30 lbs. 125 lbs. Body – Feraloy iron alloy Cl. I, Div. 2 Any non-hazardous or Class I, Div. 2 Not applicable 12-64 lbs. 125 lbs. Malleable iron, copperfree aluminum Explosionproof flexible hanger Cl. I, Groups A, B, C, D; Cl. II, Groups E, F, G; Cl. III Any hazardous Any — — Body – bronze hose Fittings – steel GUA, GUJ, GUF Explosionproof boxes and hanger covers Cl. I, Groups C, D; Cl. II, Groups E, F, G; Cl. III Any hazardous None needed — 125 lbs. Boxes – Feraloy iron alloy Cover – copperfree aluminum EAHC, EFHC Explosionproof hanger Cl. I, Groups A, B, C, D; Cl. II, Groups E, F, G; Cl. III Any hazardous None needed — 125 lbs. Body – Feraloy iron alloy Cover – copperfree aluminum UNR Explosionproof adjustable hanger Cl. I, Groups C, D; Cl. II, Groups E, F, G; Cl. III Any hazardous or non-hazardous Any — 125 lbs. Feraloy iron alloy EFH Explosionproof boxes and hangers Cl. I, Groups C, D; Cl. II, Groups E, F, G; Cl. III Any hazardous None needed 65 lbs. — Feraloy iron alloy www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1163 7L FHM Luminaire Weight Capacity (Cushion) 3-48 lbs. 1164-1165.qxp 7L 12/16/2013 7:03 PM Page 1164 Luminaire Hangers and Accessories — For Pendant Mount 7L Typical Installations 1164 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1164-1165.qxp 12/16/2013 7:03 PM Page 1165 7L Luminaire Hangers and Accessories — For Pendant Mount Typical Installations 7L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1165 1166-1167.qxp 12/16/2013 7L 7:03 PM Page 1166 AL Flexible Luminaire Hangers Cl. I, Div. 2, Groups A, B, C, D For Pendant Mount ALC Features: ALT Functions as both conduit outlet box and luminaire hanger; hubs are provided for threading the conduit directly into the hanger body; for use with incandescent, H.I.D., and fluorescent luminaires • Supporting nipple, ball or cushion type, is a universal joint permitting luminaire to swing through an angle of 20 degrees in any direction from the perpendicular • Cover has one screw hole and one open slot – easily swung aside for wiring without removal and possible loss of cover • Luminaire, conduit stem, and nipple can be assembled and wired at the work bench; the assembly is then placed in the hanger body and luminaire wires spliced to the circuit wires • Provided with a separate grounding wire for ground connections Ball Ball Cushion Cushion Standard Materials: • Body – Feraloy® • Nipple – malleable iron • Cover – sheet steel Standard Finishes: • Feraloy and malleable iron – zinc electroplate and aluminum acrylic paint • Sheet steel – electrogalvanized with chromate finish 7L Size Ranges: Ball Ball Luminaire Stem Size /2 3 /4 3 /4 1 • Conduit hubs – 3/4" to 1" • Luminaire stem – 1/2" and 3/4" • Luminaire weight – cushion type, 3 to 48 lbs.; ball type, 125 lbs. Options: The following special options are available from the factory by adding the suffix to the Cat. No.: Description Suffix Suspension attachment for span wire or threaded rod (see listings) S1 Suspension Attachment For horizontal cable or vertical support rod Conduit Size Cat. # /4 3 /4 1 ALC21 ALC22 ALC32 3 Luminaire Stem Size /2 3 /4 3 /4 1 Luminaire Luminaire Stem Conduit Weight Size Size (Lbs.) Cat. # Luminaire Luminaire Stem Conduit Weight Size Size (Lbs.) Cat. # 3 /2 /4 3 /4 /4 /4 1 3 to 6 ALT214 ALT224 ALT324 3 /2 /4 3 /4 /4 /4 1 6 to 12 ALT218 ALT228 ALT328 3 /2 /4 3 /4 /4 /4 1 12 to 24 ALT2116 ALT2216 ALT3216 /2 /4 3 /4 /4 /4 1 24 to 48 ALT2132 ALT2232 ALT3232 ALC214 ALC224 ALC324 1 3 to 6 /4 /4 1 1 6 to 12 ALC218 ALC228 ALC328 /2 /4 3 /4 /4 /4 1 12 to 24 ALC2116 ALC2216 ALC3216 1 3 /2 /4 3 /4 /4 /4 1 1 24 to 48 ALC2132 ALC2232 ALC3232 3 /2 /4 3 /4 /4 /4 1 3 /2 /4 3 /4 1 1 1 3 3 3 3 3 3 3 3 3 AL hangers can be furnished with a loop fastened to the top of the body to provide a means for suspending luminaires from vertical support rods or horizontal span wires. The loop will take a wire or cable with a maximum diameter of 3/ 8". The boss on top of the loop is tapped 3/ 8"-16 to accept a threaded rod. US: 1-866-764-5454 ALT21 ALT22 ALT32 Cushion 3 www.crouse-hinds.com Cat. # /4 3 /4 1 3 Cushion 1 1166 Conduit Size CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 3 3 3 3 3 3 3 3 1166-1167.qxp 12/16/2013 7:03 PM Page 1167 AHG, UNJ and UNJC Flexible Luminaire Hangers AHG – Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 2, Groups F, G Cl. III Wet Locations, NEMA 3, 3R UNJ, UNJC – Cl. I, Div. 2, Groups A, B, C, D For Pendant Mount 7L Features: Standard Materials: AHG • For connection to conduit hub or hub cover of supporting conduit fitting • For incandescent, H.I.D., and fluorescent luminaires • Cushion support for conduit stem is a universal joint permitting luminaire to swing through an angle of 8 degrees in any direction from the perpendicular • Gasketed by means of a durable neoprene diaphragm which excludes moisture and dirt from both luminaire and conduit system • Housing: top cap – malleable iron; bottom cap – Feraloy® iron alloy • Luminaire stem support – Feraloy iron alloy Cushion Vaportight for Class I, Div. 2; Class II, Div. 2: Class III Certifications and Compliances: • • • • • Standard Finishes: • Feraloy iron alloy and malleable iron – electrogalvanized and aluminum acrylic paint Size Ranges: • Male nipple – 3/4" • Luminaire stem – 3/4" • Luminaire weight – 4 to 30 lbs. Class I, Division 2 Class II, Division 2 Class III Wet Locations NEMA 3, 3R Luminaire Male Luminaire Stem Nipple Weight Size* Size* (Lbs.) Cat. # /4 /4 3 /4 3 3 3 UNJ UNJC Standard Finishes: Ball Cushion • Malleable iron – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural finish Luminaire Stem Size Male Nipple Size Cat. # /2 3 /4 1 /2 3 /4 UNJ1 UNJ2 Features: /4 /4 3 /4 3 4 to 8 8 to 16 16 to 30 AHG22103 AHG22104 AHG22111 • For connection to conduit hub or hub cover of supporting conduit fitting • For incandescent, H.I.D., and fluorescent luminaires • Supporting nipple, ball or cushion type, is a universal joint permitting luminaires to swing through an angle of 20 degrees in any direction from the perpendicular 7L Certifications and Compliances: • NEC: Class I, Division 2 Standard Materials: • Body and nipple – malleable iron • Clamp – copper-free aluminum 1 Size Ranges: • Male nipple – 1/2" and 3/4" • Luminaire stem – 1/2" and 3/4" • Luminaire weight: cushion type – 6 to 48 lbs.; ball type – 125 lbs. Luminaire Stem Size* Male Nipple Size* Luminaire Weight (Lbs.) Cat. # 3 /4 /4 1 /2 3 /4 3 3 3 /4 /4 /2 3 /4 6 to 12 12 to 24 24 to 48 24 to 48 1 UNJC28 UNJC216 UNJC132 UNJC232 *1/2" connection can be made by using reducers. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1167 1168-1169.qxp 12/16/2013 7L 7:04 PM Page 1168 Flexible Luminaire Hangers For Pendant Mount Dimensions Dimensions In Inches: UNJ AL Series - Ball UNJC 7L AL Series - Cushion AHG 1168 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1168-1169.qxp 12/16/2013 7:04 PM Page 1169 7L Cl. I, Div. 2, Groups A, B, C, D ARB Flexible Luminaire Hangers For Pendant Mount For GRF and VXF outlet boxes only Features: • Available in two styles – one for direct attachment to GRF cast outlet boxes by 4 screws, the other for direct attachment to 4" octagonal stamped steel outlet boxes by 2 screws; for incandescent, H.I.D., and fluorescent luminaires • Both styles available with ball or cushion support for conduit stem to permit luminaire swing in any direction; ball type provides 11 degree swing, cushion type 8 degree swing from the perpendicular • Gasketed cushion hangers for GRF are provided with a durable neoprene diaphragm which excludes moisture and dirt from both luminaire and conduit system Ball Luminaire Stem Description Size 1 /2 Surface 1 Flush /2 3 Surface /4 Ball Cushion Cat. # ARB62 ARB67 ARB662 Luminaire Stem Size Luminaire Weight (Lbs.) Cat. # /2 1 /2 1 /2 4 to 8 8 to 16 16 to 30 ARB82 ARB102 ARB122 Cushion Surface – Vaportight with Neoprene Diaphragm • Mounting plate for GRF – Feraloy® iron alloy; for 4" outlet boxes – sheet steel • Hanger body and luminaire stem support – Feraloy iron alloy • Feraloy – electrogalvanized and aluminum acrylic paint • Sheet steel – electrogalvanized with chromate finish Luminaire Weight (Max.) 125 125 125 Cushion Surface 1 Standard Materials: Standard Finishes: ARB Fits GRF and VXF Outlet Boxes For GRF and VXF outlet boxes and 4" octagonal outlet boxes Luminaire Weight (Lbs.) Cat. # /2 1 /2 1 /2 4 to 8 8 to 16 16 to 30 ARB821 ARB1021 ARB1221 1 ARB Fits GRF, VXF and 4" Outlet Boxes Size Ranges: • Luminaire stem – 1/2" and 3/4" • Luminaire weight: cushion type – 4 to 30 lbs.; ball type – 125 lbs. (ARB6 and ARB2 maximum weight 60 lbs.) Luminaire Stem Size Ball Ball Cushion Luminaire Stem Size Luminaire Weight (Max.) Cat. # /2 3 /4 60 60 ARB6 ARB2 Luminaire Stem Size Luminaire Weight (Lbs.) Cat. # /2 1 /2 1 /2 4 to 8 8 to 16 16 to 30 ARB8 ARB10 ARB12 1 1 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 7L Cushion Copyright© 2013 Eaton’s Crouse-Hinds Business 1169 1170-1171.qxp 12/16/2013 7:04 PM Page 1170 Cl. I, Div. 2, Groups A, B, C, D UNE, UNH and UNHC Flexible Luminaire Hangers 7L For Pendant Mount The following applies to all items on this page: Applications: • Provides a simple, inexpensive, quick disconnect method for hanging pendant luminaires; for incandescent, H.I.D., and fluorescent luminaires • Permits free swing in any direction to prevent damage to luminaire stem; cushion style provides additional protection from vibration to prolong lamp life Features: • Female hooks and loops are used with rigid conduit luminaire stems to suspend luminaires; they may also be used with male hooks and loops, threaded into a conduit outlet hub • All hooks and loops are provided with openings for passage of luminaire wires; luminaire, conduit stem, and hook or loop can be assembled and wired at the work bench; the assembly is then hung on the fixed hook and connection made • For ease of relamping and maintenance, the outlet fitting can be equipped with an attachment plug receptacle cover and a matching plug cap used with the luminaire assembly; for permanent wiring, a wire hole cover may be used Male Female Male UNH Female UNE UNE and UNH Flexible Luminaire Hangers For Pendant Mount Type Style Male UNH Female Luminaire Stem Size Luminaire Weight (Lbs.) Cat. # 1 /2 3 /4 1 /2 3 /4 125 125 125 125 UNH16 UNH26 UNH1 UNH2 /2 /4 1 /2 3 /4 125 125 125 125 UNE16 UNE26 UNE1 UNE2 1 Male 3 UNE Female Applicable to UNE and UNH (upper listings) only: Features: • Diameter of wire opening: 1/2" Standard Materials: 7L • Malleable iron Standard Finishes: • Cadmium electrogalvanized and aluminum acrylic paint Size Ranges: • Luminaire stem or hub – 1/2" and 3/4" • Luminaire weight – 125 lbs. Female Female Cushion Applicable to UNH and UNHC (lower listings) only: UNH and UNHC Flexible Luminaire Hangers Features: Type Style • Hooks are shaped to permit easy installation of large heavy luminaires, such as H.I.D. and fluorescent units • Diameter of wire opening: 5/8" UNH Female Luminaire Stem Size Luminaire Weight (Lbs.) Cat. # 1 /2 125 UNH182 /4 3 /4 3 /4 12 to 24 24 to 48 48 to 64 UNHC216 UNHC232 UNHC264 3 UNHC Female Cushion Standard Materials: • Copper-free aluminum Standard Finishes: • Natural Size Ranges: • Luminaire stem – 1/2" and 3/4" • Luminaire weight: cushion type – 12 to 64 lbs.; plain type – 125 lbs. 1170 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1170-1171.qxp 12/16/2013 7:04 PM Page 1171 7L No Wireway Opening UNHC Flexible Luminaire Hangers For Support Only CHS Conduit Clamp; UNH Conduit Hook; For Pendant Mount Fluorescent Luminaires Applications: • Used for support of pendant fluorescent luminaires • UNHC provides cushion support for luminaires suspended by 1/4" or 5/16" threaded rod, and is used with the ring of CHS conduit clamps • UNH hook provides an extremely simple means of conduit suspension for the unwired end of a fluorescent luminaire, as it merely hooks over the horizontal supporting conduit UNHC Cushion Luminaire Hangers CHS Conduit Clamp and UNH Hook Features: • The bushing in UNHC cushion hangers is tapped for both 1/4" and 5/16" suspension rod, with the lower half tapped 5/16"; either size rod can be used without reversing the bushing • CHS conduit clamp firmly grips the conduit and the ring at bottom accepts either a hooked rod or the UNHC cushion hanger for threaded rod; will also accept UNH and UNHC hangers for conduit stem listed on the preceding page • The UNH conduit hook fits over conduit up to and including 1" and has a hub for attachment of a 1/2" conduit stem Clamp Luminaire Weight (Lbs.) Support Rod Tap Cat. # 12 to 24 24 to 48 48 to 64 1 /4"-20 and 5 /16"-18 UNHC2816 UNHC2832 UNHC2864 Hook Conduit Size Clamp Cat. # Hook Cat. # /2 /4 1 CHS1437 CHS2437 CHS3437 UNH13 1 3 Hook Hub Size /2 1 Standard Materials: • UNHC – copper-free aluminum • CHS: body – malleable iron; clamp – copper-free aluminum; ring – steel wire • UNH – Feraloy® iron alloy Standard Finishes: 7L • Copper-free aluminum – natural finish • Feraloy and malleable iron – electrogalvanized and aluminum acrylic paint • Steel wire – electrogalvanized with chromate finish Size Ranges: • Luminaire stem (UNH) – 1/2" • Conduit (CHS): 1/2" to 1" • Luminaire weight: UNHC cushion – 12 to 64 lbs.; CHS, UNH – 125 lbs. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1171 1172-1173.qxp 12/16/2013 7L 7:04 PM Page 1172 FHM Power Hook Luminaire Hangers For Pendant Luminaires Features: FHM • For mounting H.I.D. type luminaires in non-hazardous locations • Power hook housing has two 3/4" through-feed hubs and one 3/4" hub on the top for pendant mounting; throughfeed hubs are furnished with flush plugs • Cast mounting lugs are provided for direct ceiling mounting • Housing contains a roomy 15 cu. in. splicing chamber and interlocking type receptacle with leads • Plugs and receptacles are interlocking type to prevent accidental disengagement; when plug is inserted, hook is blocked and luminaire assembly cannot be removed; to service the luminaire, pull the plug, unhook the loop luminaire assembly, and take it to a convenient servicing area • Loop can move a maximum of 30°, allowing the power hook to be mounted on a canted ceiling; the luminaire assembly will hang true to the vertical • Loop and hook are shaped for selfalignment and resist twisting of luminaire by gusts of wind or light drafts • Supporting loop is furnished with 16" of #16-3/C type SO cord and an interlocking type plug For H.I.D. Type Luminaires with Voltages up to 480 Volts Loop Hubs* Plain 3 /4 Luminaire Stem* Luminaire Weight (Lbs.) Cat. # /4 125 FHM201 3 Plain Dimensions In Inches: Certifications and Compliances: • Meet UL and NEMA requirements for the listed electrical ratings 7L Standard Materials: • Power hook body – copper-free aluminum • Access cover – zinc plated cold rolled steel • Loop – copper-free aluminum Standard Finishes: • Copper-free aluminum – natural finish • Steel – electrogalvanized with chromate finish Plain Size Ranges: • Hubs – 3/4" • Luminaire weights: loop – up to 125 lbs. • Loop luminaire stem size – 3/4" Electrical Rating Ranges: • 480 volts, 14 amps, 2 wire, 3 pole *1/2" connection can be obtained by using reducers. 1172 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1172-1173.qxp 12/16/2013 7:04 PM Page 1173 ECHF Flexible Luminaire Supports Cl. I, Div. 1 & 2, Groups A, B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III For Pendant Mount Explosionproof Dust-Ignitionproof 7L Applications: ECHF Series Flexible Luminaire Supports are used in hazardous locations: • Where a luminaire must hang more than 12" from its supporting junction box (as specified by NEC Article 501 and CEC Part I Section 18) • To assure that luminaires hang plumb and will swing freely if accidentally struck; prevents damage to luminaire and supporting outlet fitting ECHF Ordering Information: Description Features: • Complies with NEC Article 501/CEC Part I Section 18 • Free swinging in any direction through a large arc • Good electrical continuity – no bonding jumpers needed • Watertight construction • Insulating liner of asphalt impregnated fiber to protect conductors • Constructed to reinforced flexible metal hose • Two female end fittings, each with a removable short nipple • Nipples fit set-screw type luminaire hubs • Female end fittings are equipped with set-screws to prevent turning during relamping and loosening of fitting with vibrations Flexible Length Nipple Size Overall Length Cat. # /2 3 /4 10 10 ECHF14 ECHF24 /2 /4 12 12 ECHF16 ECHF26 /2 /4 14 14 ECHF18 ECHF28 /2 /4 16 16 ECHF110 ECHF210 /2 /4 18 18 ECHF112 ECHF212 /2 /4 21 21 ECHF115 ECHF215 /2 /4 24 24 ECHF118 ECHF218 1 4 1 6 3 1 8 3 1 10 3 1 12 3 1 15 3 1 18 3 Certifications and Compliances: 7L • NEC/CEC: Class I, Groups A, B, C, D Class II, Groups E, F, G Class III • UL Standard: 1203 • CSA Standard: C22.2 No. 30 Standard Finishes: • Brass and bronze – natural Standard Materials: • • • • Inner core – brass Outer braid – bronze End fittings – bronze End fittings – brass (CSA certified units) Options: Description Suffix Material – stainless steel hose and end fittings............................................ S516 Finish – flexible neoprene protective coating.................................................. S758 Special lengths and sizes available........................Detailed information on request Size Ranges: • Flexible length – 4" to 18" • Nipple size – 1/2" and 3/4" (see "Options") • Luminaire weight – up to 125 lbs. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1173 1174-1175.qxp 12/16/2013 7L 7:04 PM Page 1174 EAHC and EFHC Luminaire Hangers Cl. I, Div. 1 & 2, Groups A*, B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III For Pendant Mount Applications: Mounting Strap EAHC* and EFHC EAHC and EFHC Luminaire Hangers are for use in hazardous areas to: • Suspend explosionproof pendant luminaires from the conduit system • Function as both conduit outlet box and luminaire hanger Mounting strap can be furnished to fasten luminaire hangers to mounting surface, independent of conduit straps. To order, add suffix S294 to EAHC or EFHC Cat. No. Features: Suspension Attachment • Through-feed hubs are provided for threading the conduit directly into the hanger body • Has large threaded cover for accessibility and ease of wiring • Bottom hub, threaded or union style, is equipped with set-screws to securely lock luminaire stem in place; takes conduit stem or EC flexible luminaire hanger for stems longer than 12" (in compliance with NEC Article 501 and CEC Part I Section 18) With Union Hub EAHC and EFHC hangers can be furnished with a loop fastened to the top of the body to suspend luminaire and conduit from vertical support rods or horizontal span wires. The loop will take a wire or cable with a maximum diameter of 3/ 8". The boss on top of the loop is tapped 3/ 8"–16 to accept a threaded rod. To order, add suffix S1 to Cat. No. Certifications and Compliances: With Threaded Hub • NEC/CEC: EAHC – Class I, Groups A, B, C, D Class II, Groups E, F, G Class III EFHC – Class I, Groups C, D Class II, Groups E, F, G Class III • UL Standard: 1203 • CSA Standard: C22.2 No. 30 Ordering Information: Luminaire Hub Stem Size Size EAHC* 1 /2 3 /4 3 /4 Standard Materials: Threaded Hub for Luminaire Stem Cat. # Union Hub for Luminaire Stem Cat. # EAHC2701 EAHC2601 EAHC2702 EAHC2602 /2 /4 EAHC3701 EAHC3601 EAHC3702 EAHC3602 /2 /4 EFHC2701 EFHC2601 EFHC2702 EFHC2602 /2 /4 EFHC3701 EFHC3601 EFHC3702 EFHC3602 1 1 7L Explosionproof Dust-Ignitionproof 3 EFHC • Bodies – Feraloy® iron alloy • Covers – copper-free aluminum 1 /4 3 3 1 Standard Finishes: 1 • Feraloy – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural Dimensions 3 In Inches: Options: Description Suffix Finish – Corro-free™ epoxy enamel ..... S752 Suspension attachment for span wire or threaded rod (see listings) ................... S1 Mounting strap (see listings) ............... S294 Size Ranges: • Conduit hubs – 3/4" and 1" • Luminaire stem – 1/2" and 3/4" • Luminaire weight – 125 lbs. *EAHC only. 1174 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1174-1175.qxp 12/16/2013 7:04 PM Page 1175 EFH Flexible Cushion Luminaire Hangers Explosionproof Dust-Ignitionproof Cl. I, Div. 1 and 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III For Pendant Mount 7L Applications: EFH Flexible Cushion Luminaire Hangers are used in hazardous locations: • Where a luminaire must hang more than 12" from its supporting junction box (as required by NEC Article 501 and CEC Part I Section 18) • To assure that luminaires hang plumb and will swing freely if accidentally struck; prevents damage to luminaire, stem, and supporting outlet box • To provide a cushion support, prolonging lamp life and protecting the luminaire from shock and vibration; for luminaires weighing up to 65 lbs. EFHX Body Hub Size* /2 and 3/4 /2 and 3/4 Features: • Complies with NEC Article 501 and CEC Part I Section 18 • Free swinging in any direction through an angle of 15 degrees from perpendicular • Weight of luminaire is supported by a high strength brass bellows and a stainless steel cushioning spring • Two part assembly consisting of luminaire hanger cover and CPS12 outlet box; provides a wide variety of conduit arrangements; a set-screw locks the conduit stem in place Certifications and Compliances: Luminaire Stem Size With Mtg. Feet Cat. # /2 /4 EFHX111 EFHX221 1 1 1 3 Cushion Luminaire Hanger Only Stem Size Cat. # /2 3 /4 EFH01 EFH02 1 • NEC/CEC: Class I, Groups C, D Class II, Groups E, F, G Class III • UL Standard: 1203 • CSA Standard: C22.2 No. 30 Dimensions 7L In Inches: Standard Materials: • Feraloy® iron alloy Standard Finishes: • Electrogalvanized and aluminum acrylic paint Size Ranges: • Conduit hubs – 3/4" with 3/4" to 1/2" reducers • Luminaire stem – 1/2" and 3/4" • Luminaire weight – 65 lbs. max. *Furnished with four / " standard taper tapped, integrally bushed hubs. Each hub as a / " to / " reducer. Three hubs are plugged. 3 3 4 www.crouse-hinds.com 4 1 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1175 1176-1177.qxp 12/24/2013 7L 3:19 PM Page 1176 Condulet® Conduit Outlet Boxes with Covers Explosionproof Dust-Ignitionproof Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Applications: CPS Series Conduit Outlet Boxes are installed in conduit systems in hazardous areas to: • Protect conductors in threaded rigid conduit • Act as pull and splice boxes • Change conduit direction • Interconnect lengths of conduit • Act as luminaire hangers with hub covers • Provide access to conductors for maintenance and future system changes Box with Hub Cover Box with Blank Cover Hub Size Body* Hub Size Cat. # /2 and 3/4 CPS12026 /2 and /4 /2 and 3/4 1 Features: 3 1 Cover /2 /4 Cat. # CPS12021 CPS12022 1 3 1 CPS Conduit Outlet Boxes have: • Two types of cover: -Blank for splice or pull box use -Threaded hub for mounting luminaires • Wide, accurately machined body and cover mating surfaces, to ensure flame-tight joint • Blind tapped holes for cover screws to further ensure flame-tightness • Removable mounting feet for flush or surface mounting to wall or ceiling Body Certifications and Compliances: Cat. # Hub Size Cat. # /2 and 3/4 CPS12 1 /2 3 /4 CPS021 CPS022 1 • NEC/CEC: Class I, Groups C, D Class II, Groups E, F, G Class III • UL Standard: 1203 • CSA Standard: C22.2 No. 30 7L Hub Covers Hub Size* *Furnished with four plugged. / " standard taper tapped, integrally bushed hubs. Each hub has a / " to / " reducer. Three hubs are 3 3 4 Dimensions In Inches: Standard Materials: • Feraloy® iron alloy Standard Finishes: • Electrogalvanized and aluminum acrylic paint Options: Description Corro-free™ epoxy enamel 1176 www.crouse-hinds.com Suffix (information available on request) US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 4 1 2 1176-1177.qxp 12/24/2013 3:19 PM Page 1177 GUA Series Outlet Bodies and Luminaire Hanger Covers Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III 7L Explosionproof Dust-Ignitionproof Applications: GUA, GUF and GUJ Outlet Bodies are used: • With luminaire canopies, union hub and nipple covers for mounting EVA, EVM, EVLP, and EVF luminaires Features: • A threaded cover opening in the side of the canopy permits access to the interior for making splices or taps • The luminaire with its conduit stem and canopy is wired before installation, which eliminates wire twisting when the canopy is screwed into the outlet body • Union hub covers permit the cover to be screwed into the body without twisting wire leads • All covers have set-screws to lock the conduit stem or EC series flexible luminaire support firmly to the cover GUAT GUA Hub Size (In.) Cat. # Hub Size (In.) Cat. # /2 3 /4 1 GUA160 GUA260 GUA360 1 /2 3 /4 1 GUAT160 GUAT260 GUAT360 1 Certifications and Compliances: GUAC • NEC/CEC: Class I, Groups C, D Class II, Groups E, F, G Class III • UL Standard: 1203 • CSA Standard: C22.2 No. 30 GUAX Hub Size (In.) Cat. # Hub Size (In.) Cat. # /2 3 /4 1 GUAC160 GUAC260 GUAC360 /2 3 /4 1 GUAX160 GUAX260 GUAX360 1 1 Standard Materials: 7L Outlet bodies: • GUA Series – Feraloy iron alloy • GUFX – copper-free aluminum Luminaire hanger covers: • GUA068 – Feraloy iron alloy • GUA0687, GUA0672 – copper-free aluminum GUAL Hub Size (In.) Cat. # /2 3 /4 1 GUAL160 GUAL260 GUAL360 1 Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural Dimensions In Inches: Options: Description Suffix Finish – Corro-free™ epoxy enamel................................................ S752 Size Ranges: • Bodies – 1/2" to 1" hubs • Canopies – 1/2", 3/4" and 11/4" luminaire stem • Union hub and nipple covers – 1/2" and 3 /4" luminaire stem GUA Series Hub Size /2 3 /4 1 1 www.crouse-hinds.com a b c d e 3 /2 31/2 31/2 2 2 25/16 3 3 3 5 /8 /4 7 /8 /8 /8 1 1 US: 1-866-764-5454 CAN: 1-800-265-0502 3 7 7 Copyright© 2013 Eaton’s Crouse-Hinds Business 1177 1178-1179.qxp 12/16/2013 7:04 PM Page 1178 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III GUA Series Outlet Bodies and Luminaire Hanger Covers 7L GUFX Explosionproof Dust-Ignitionproof Luminaire Hanger Covers For GUA and GUF Series Junction Boxes Hub Size Cat. # /2 /4 GUFX160 GUFX260 1 3 Nom. Dia. Luminaire Luminaire Luminaire Covers Nipple Cover Stem Canopies Union Hub Covers Opening Size Cat. # Cat. # Cat. # 3 /4 3 GUA068 GUA0687 Dimensions In Inches: Hanger Covers 7L GUA 068 GUF Series Hub Size 1 /2 3 /4 a b c d e f g 31/2 31/2 2 2 3 3 5 /8 3 /4 7 /8 7 /8 5 /16 5 /16 53/8 53/8 1 31/2 23/8 3 7 /8 1 5 /16 53/8 GUA 0687 GUA 0671 1178 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business GUA0672 1178-1179.qxp 12/16/2013 7:04 PM Page 1179 UNR Adjustable Luminaire Hangers; COUP Locking Couplings Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Explosionproof Dust-Ignitionproof 7L For Pendant Mount Applications: UNR Adjustable Luminaire Hangers are used in hazardous areas to: • Mount between a luminaire and its outlet box so that the luminaire can be adjusted within the range of 0 degrees to 90 degrees • Permit pendant type luminaires to illuminate vertical surfaces such as a control board • Hang luminaires plumb when the supporting outlet box is not horizontal Certifications and Compliances: UNR Adjustable Luminaire Hanger • NEC: Class I, Groups C, D Class II, Groups E, F, G Class III • UL Standard: 1203 Standard Materials: • Feraloy iron alloy Standard Finishes: Features: The luminaire is nippled onto one end of the UNR, and the other end of the UNR is nippled into the support outlet box • Set-screws are located on each end to lock the nipples in place to prevent loosening in relamping or from vibration • Adjustment of UNR to the angle setting needed provides for the desired angle of the luminaire • Degree markings are cast into the UNR • Two set-screws and a large stud and nut are provided, which are tightened to clamp the unit rigid Applications: Size Ranges: • Hub – 3/4" • Luminaire weight – 125 lbs. Angle Adjustment Cat. # /4 0° to 90° UNR29 3 Dimensions In Inches: Certifications and Compliances: COUP Locking Couplings • UL Standard: 1203 Standard Materials: • Feraloy iron alloy Standard Finishes: • Electrogalvanized and aluminum acrylic paint Size Ranges: • Hub size – 1/2" to 1" • Stem size – 1/2" and 3/4" Features: Hub Size 7L COUP Locking Couplings are used in both hazardous and non-hazardous areas to: • Lock a luminaire conduit stem into a conduit hub to prevent the conduit stem from loosening when the luminaire is relamped and torque transferred to luminaire stem • Prevent loosening of luminaire stem due to vibration • Hang pendant type luminaires from standard cast outlet boxes which do not have set-screws in the hub where the luminaire stem is attached • Electrogalvanized and aluminum acrylic paint • The large end is slipped over the cast hub and the set-screws tightened; the luminaire stem is slipped through the small end and threaded securely into the cast hub; the set-screws in the small end are then tightened, thereby preventing the stem from turning • Permits support of luminaire from conduit hub of a hazardous location outlet body www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Hub Size Stem Size Cat. # /2 3 /4 3 /4 1 1 /2 1 /2 3 /4 3 /4 COUP101 COUP201 COUP202 COUP302 1 Copyright© 2013 Eaton’s Crouse-Hinds Business 1179 1180-1181.qxp 12/17/2013 5:50 PM Page 1180 7L 7L 1180 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1180-1181.qxp 12/17/2013 5:50 PM Page 1181 Portable Lighting Hazardous and Non-hazardous 8L Description Page No. Application/Selection see page 1182 Hand Lamps VS Series Incandescent EVH Series Incandescent EVH Series Fluorescent see page 1183 see page 1184 see pages 1188–1189 Portable Floodlights RCDER Series Incandescent EVP Series H.I.D. see page 1185 see page 1187 Work Lights EVH Series Fluorescent see pages 1188–1189 8L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1181 1182-1183.qxp 12/16/2013 7:05 PM Page 1182 Portable Lighting 8L Hazardous and Non-hazardous Locations Application and Selection Quick Selector Chart Applications: Portable luminaires and accessories can be used: • In areas made hazardous by the abnormal presence of flammable gases and vapors, combustible dusts, or easily ignitable fibers and flyings • In areas where combustible dusts and flammable gases are present simultaneously • In aircraft manufacturing and maintenance facilities, shipyards, paint spray booths, refueling depots, storage tank cleanings, railcar manufacturing and maintenance facilities, refineries, chemical and petrochemical plants, textile mills, grain elevators, pharmaceutical plants, sewage treatment plants, and wastewater treatment plants • During plant 'shut downs' for maintenance and installation requirements • In any adverse environment where portable lighting is preferred or required • In locations where fixed lighting is not practical • For task oriented lighting • For emergency lighting applications • When inspecting aircraft wing tanks, vats, process vessels, fuel tanks, etc. (hand lamps) Considerations for Selection: Environmental: • What is the hazardous area classification (NEC/CEC) of the location in which the luminaires will be installed? • What wattages and light source (ie. fluorescent) will provide the desired light levels? • Type of luminaire required: handlamp, portable flood, or other special requirements Table 500.8(C) Identification Numbers. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Temperature Class (T Code) T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 8L Quick Selector Chart Luminaire EVH Hand Lamp (Incandescent) NEC Hazardous Area Compliances Cl. I, Groups C and D Cl. II, Group G Cl. III Lamp Watts 100 max. Volts 250 VAC EVH Hand Lamp (Fluorescent) Cl. I, Groups C and D Cl. II, Groups E, F, G Cl. III 13, 15 120, 220-50 EVP Cl. I, Groups C and D Cl. II, Groups F and G Cl. III 35-150 120, 277, 347 RCDER Cl. I, Groups C and D 150-500 VS Non-hazardous areas 100 max. 1182 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1182-1183.qxp 12/16/2013 7:05 PM Page 1183 VS Portable Hand Lamps Weather Resistant 8L Incandescent Accessories Applications: The incandescent VS Portable Hand Lamps are used: • In wet or corrosive locations to exclude moisture, dirt, corrosive chemicals, etc. • Where an incandescent lamp of up to 100 watts is required in a portable hand lamp Glass Globes Polycarbonate Globes Description Maximum Lamp Size Clear Glass, (Heat Resisting) 100W, V63 A-23 – 67/8"* Clear, Polycarbonate, Plain 75W, A-21"* Features: • Enclosed and gasketed • Flexible cord or cable is attached through a watertight gland in the handle • Is of rugged construction • Clamp type guard available • Provision is made in the lamp receptacle for a third conductor to ground all noncurrent carrying metal parts Certifications and Compliances: Cat. # V470 (No Cable Included) • Weather resistant • UL Standard: 298 Globe Length (Note: CEC/CSA Certified VS Hand Lamps - Eaton's Crouse-Hinds Canada fixtures only). Standard Materials: 67/8" Note: Guards Max. Lamp Size Cord Dia. Rubber Cat. # 100W A-23* 0.125 to 0.625 VS30 Furnished with clear globe, wire guard and 4 rubber bushings. • Handle – molded rubber • Globe – clear, plain glass • Guard – cast aluminum or steel wire Standard Finishes: • Handle – natural • Guard – zinc plated Description Size Steel Wire 67/8" Globe VS97 Cat. # Size Ranges: 8L Lamp Receptacle (medium base) • Up to 100 watt, A-23 lamp • 0.250 to 0.625 cord O.D. Description Size Composition keyless 660W, GS156 600V Cat. # Cord Gland Bushings Description Size Rubber 0.125 to 0.250 Cord 0.250 to 0.375 Cord 0.375 to 0.500 Cord 0.500 to 0.625 Cord Cat. # BUSH92 BUSH93 BUSH94 BUSH05 *Will take lamps with maximum dimensions of 61/2" long and 27/8" diameter. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1183 1184-1185.qxp 12/16/2013 8L 7:05 PM Page 1184 EVH Portable Hand Lamp Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1 & 2, Group G Cl. III Cl. I, Zone 1 IIB Applications: EVH106 is used: • As a portable hand lamp in hazardous areas • In inspecting aircraft wing tanks, vats, process vessels, fuel tanks, etc. Features: • Pressure connector terminals for portable cord • Lightweight – 41/4" lbs. • Designed for rough service – swivel hook, ease in relamping Certifications and Compliances: • NEC/CEC: Class I, Division 1 and 2, Groups C, D – 100 watts max. Class I, Zone 1 IIB Class II, Division 1 and 2, Group G – 75 watts max. Class III – 75 watts max. • UL Standard: 781 • CSA Standard: C22.2 No. 137 Standard Materials: Ordering Information • Guard and globe holder – copper-free aluminum • Handle – molded phenolic composition • Globe – glass, heat- and impact-resistant Type Cord Dia. EVH106 Model M10 0.375 to 0.625 Replacement Parts Standard Finishes: • Natural 8L Cat. # Size Ranges: Description Cat. # Guard and globe assembly Handle assembly (including lampholder) Cord connector assembly Lampholder only EVH606 EVH607 EVH605 EVH:05-279-A • #16 – 3 type SO cord/cable is to be used (not supplied) Capacity Ranges: • 50 to 100 watt, A-21 • Max. volts – 250 VAC Temperature Performance Data: (based on 40°C Ambient) Class I, Groups C, D Class II, Group G Class III T3C T3C T3C Note: See Section 2P of this catalog for suitable male plug. 1184 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1184-1185.qxp 12/16/2013 7:05 PM Page 1185 Portable Floodlights Cl. I, Div. 1 and 2, Groups C, D Cl. I, Zone 1 II(B) A 8L Incandescent Applications: Standard Materials: RCDER Portable Incandescent Luminaires provide general illumination in locations having hazardous atmospheres, such as: • Oil refineries • Oil and gasoline loading docks • Aircraft servicing docks and shelters • Distilleries • Paint manufacturing plants • Pumping stations • Other Class I, Groups C and D locations • Body – copper-free aluminum • Lens – glass, heat- and impact-resistant RCDER-6 RCDER-10 Cat. No. 44655B Cat. No. 47283A Standard Finishes: • Natural Size Ranges: • Take cable with O.D. of 0.375" to 0.500" Capacity Ranges: • RCDER-6 – 150 watt, PAR38 or R40; 300 watt, R40 (medium base) • RCDER-10 – 500 watt, PAR64 (Ext. Mog End Prong) Features: • Wheel base • Carrying handle • Adjustment allows rotation of 75° vertically • Locking screws hold housing firmly in position • Door which threads into housing includes heat- and impact-resistant lens; door has notches or projections for ease of removing or tightening • Factory-sealed Ordering Information: After identifying the hazardous area, select the model of luminaire required for that area. Then from the photometric data, select appropriate Cat. No. based on type of mounting desired (Example: RCDER-10 No. 47283A). Certifications and Compliances: 8L • NEC/CEC: RCDER – Class I, Division 1 and 2, Groups (C), D; Class I, Zone 1 II(B) A (see photometric data listing) • UL Standard: 844 • CSA Standard: C22.2 No. 137 (RCDER6 only) (Note: CEC/CSA Certified RCDER6 - Eaton's CrouseHinds Canada luminaires only). Temperature Performance Data: (based on 40°C Ambient) RCDER-6 RCDER-10 150W 300W T3B T2B 500W T3C www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1185 1186-1187.qxp 12/16/2013 7:05 PM Page 1186 Portable Mounted Lights 8L Photometric Data Dimensions and Weights RCDER Photometric Data: Beam Spread Lamp Watts and Type RCDER-6 150 Watt PAR38 Flood 150 Watt PAR38 Spot 300 Watt R40 Flood Location Hor. Vert. Beam Lumens Av. Max. Candle Power Class I, Groups C, D (Zone 1 IIB) 60° 60° 1690 4000 28° 28° 1200 11500 123° 123° 3200 1950 60° 60° 3100 8900 19° 14° 3000 110000 35° 19° 3300 37000 55° 32° 3400 13000 Class I, Groups D (Zone 1 IIA) 300 Watt R40 Spot RCDER-10 500 Watt, PAR64 (500 PAR64/NSP) Class I, Group D 500 Watt, PAR64 (500 PAR64/MFL) 500 Watt, PAR64 (500 PAR64/WFL) (Zone 1 IIA) Dimensions 8L In Inches: RCDER-6 RCDER-10 Fixture Weights: RCDER-6 RCDER-10 1186 Cat. # Lbs. (Net) 44655 47283 26.0 25.0 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1186-1187.qxp 12/16/2013 7:05 PM Page 1187 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1 & 2, Groups F, G Cl. III Cl. I, Zone 1 IIB Wet Locations Marine Locations EVP Portable H.I.D. Floodlight 8L Applications: Key Features The EVP Portable H.I.D. Floodlight† is suitable for maintenance or emergency lighting: • In areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitable fibers and flyings • In aircraft manufacturing and maintenance facilities, shipyards, refueling depots, storage tank cleaning, railcar manufacturing and maintenance facilities, refineries, chemical and petrochemical plants, textile mills, grain elevators and pharmaceutical plants, printing operations, wastewater, and sewage treatment plants • In any adverse environment where portable lighting is preferred or required • In locations where lighting is not practical • For task oriented lighting • Strong spun aluminum • Provides stability, allows wheel base fixture to be hung on a wall or lowered in an inverted position • Sturdy hand knob • Tightens to hold position for steady illumination and easy aiming • Plastic rib covered • Firm, non-slip grip for handle transporting fixture • Aluminum specular • Directs intense beam for reflector better visibility • Tempered, 3/4" thick • Heavy duty service cover glass • Nitrile rubber O-ring • Excellent sealing for use in gasket wet locations • Strain relief clamps • Provides extra protection against cord damage • Pre-wired, factory• Saves on installation time and sealed 100' of 16/3 maintenance costs type SOW cord supplied • Lightweight (25 lbs.) • Easy to handle when transporting • Fixture housing has a • Highly visible for safety safety yellow finish precautions Certifications and Compliances: • EVP and EVPG • NEC/CEC: Class I, Division 1 & 2, Groups C, D Class I, Zone 1 IIB Class II, Division 1 and 2, Groups F, G Class III Wet Locations Marine Locations • UL Standards: 781, 595, 1572 • CSA Standard: C22.2 No. 137, No. 12 Standard Materials: Housing – copper-free aluminum Wheel base – spun aluminum Handle – plastic rib covered aluminum Reflector – aluminum O-ring gasket – Nitrile rubber Electrical Ratings: High pressure sodium – (medium base) • 70, 100, & 150 watt • 120 volt 60 Hz Metal Halide – (double end) • 70 watt • 120, 277 & 347 volt; 60 Hz Ordering Information: Cl. I, Div. 1, Groups C, D Cl. II, Div. 1, Group F Cat. # 70 watts HPS, 120 volts 100 watts HPS, 120 volts 150 watts HPS, 120 volts 70 watt MH, 120 volts 70 watt MH, 277 volts 70 watt MH, 347 volts EVP4070 EVP4100 EVP4150* EVP9070 EVP9070/277 EVP9070/347 Note: Cl. I, Div. 1, Groups C, D Cl. II, Div. 1, Groups F, G Cl. III Cat. # 100 watts HPS, 120 volts 70 watt MH, 120 volts 70 watt MH, 277 volts 70 watt MH, 347 volts EVPG4100 EVPG9070 EVPG9070/277 EVPG9070/347 Fixtures for grain dust applications have a special limiting device to prevent the fixture head from being positioned in an upright position limiting dust build-up. Temperature Performance Data: Class I, Division 1 Class II, Division 1 Cat. # Max. Ambient °C T-Rating Groups T-Rating Groups EVP4070 EVP4100 EVP4150 EVP9070 EVPG4100 EVPG9070 40 40 25 40 40 40 T4A T4A T3C T4 T4A T4 C, D C, D C, D C, D C, D C, D T3 T3 — T3 T3C T4 F F — F F, G F, G 8L • • • • • Benefits Fixture Weight: • 25.5 lbs. Photometric Data: EVP4070 †EVP fixtures are not supplied with plug. *Class II not available. EVP4100 Degree from beam axis EVP4150 Dimensions: 121/2" D × 131/8" W × 157/8" H www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1187 1188-1189.qxp 12/16/2013 8L 7:05 PM Page 1188 EVH Fluorescent Hand Lamps & Work Lights Cl. I, Div. 1 and 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Cl. I, Zone 1 IIB Applications: Portable hand lamps and work lights can be used: • In areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitable fibers and flyings • In aircraft manufacturing and maintenance facilities, shipyards, refueling depots, storage tank cleaning, railcar manufacturing and maintenance facilities, refineries, chemical and petrochemical plants, textile mills, grain elevators, pharmaceutical plants, sewage treatment plants, and wastewater treatment plants • During plant 'shut downs' for maintenance and installation requirements • In any adverse environment where portable lighting is preferred or required • In locations where fixed lighting is not practical • For task oriented lighting • For emergency lighting applications • When inspecting aircraft wing tanks, vats, process vessels, fuel tanks, etc. Features: • Built-in metal reflector which eliminates glare and blinding, focusing all light on subject • Protected by patented shock absorbers to withstand rough usage • Enclosed ballast, remote from light source for easier handling and maneuverability • Special rubber compound bumper guards and end caps combined with cast guard and metal rods, protecting against damage from falling objects, bumping, or dropping • Luminaires come complete with lamp(s) and cord • The new EVH2625E and EVH2650E incorporate an electronic ballast in the handle for efficiency, cool operation, and easy handling 8L Certifications and Compliances: • NEC: Fluorescent Work Lights (15 watt units) Class I, Division 1 and 2, Group D Class I, Zone 1 IIB Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • NEC: Fluorescent Hand Lamps (13 and 26 watt units) Class I, Division 1 and 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III • FM: Classification 3615 • CSA: C22.2 Temperature Performance Data: Based on 40°C Ambient Temperature Cat. # Class I, Div. 1 T-Rating Groups Class II, Div. 1 T-Rating Groups EVH1525 EVH1550 EVH1325 EVH1350 EVH2625 EVH2650 EVH1325 IB EVH1350 IB EVH2625E EVH2650E T5 T5 T5 T5 T3 T3 T5 T5 T6 T6 T5 T5 T5 T5 T3 T3 T5 T5 T6 T6 D D C, C, C, C, C, C, C, C, D D D D D D D D E, E, E, E, E, E, E, E, E, E, F, F, F, F, F, F, F, F, F, F, Ordering Information: EVH Fluorescent Work Lights Cord Line Voltage Watts Length (ft.) Lamp Type 60 Hz 15 25 ft. F15T8 120 15 50 ft. F15T8 120 Cat. # EVH1525 EVH1550 EVH Fluorescent Hand Lamps (with Magnetic Ballast in Cord) Standard Materials: Cord Watts Length (ft.) Lamp Type Cat. # 13 13 26 26 25 50 25 50 ft. ft. ft. ft. F13TT F13TT F26DTT F26DTT EVH1325 EVH1350 EVH2625 EVH2650 13 13 26 26 25 50 25 50 ft. ft. ft. ft. F13TT F13TT F26DTT F26DTT EVH1325/220 EVH1350/220 EVH2625/220 EVH2650/220 Options: Line Voltage 60 Hz 120 120 120 120 50 Hz 220 220 220 220 Description Suffix An isolated ballast is available on the EVH 13 Watt hand lamps for additional protection IB EVH Fluorescent Hand Lamps (with Electronic Ballast in Handle) • Body and inline ballast unit – aluminum • Tube shield – annealed glass • Bumper guards – rubber Standard Finishes: • • • • Aluminum body – white epoxy (hand lamps) Aluminum body – natural (work lights) Inline ballast unit – natural Rubber bumper guards – safety yellow Size Ranges: Cord Line Voltage Watts Length (ft.) Lamp Type Cat. # 60 Hz 26 25 ft. CF26DD/E/841 EVH2625E 120 26 50 ft. CF26DD/E/841 EVH2650E 120 • Supplied with 18 / 3 SOW cord (25 ft or 50 ft) Electrical Ratings: • 13 to 26 Watts • Max. volts 220VAC 1188 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 G G G G G G G G G G Copyright© 2013 Eaton’s Crouse-Hinds Business 50 50 50 50 1188-1189.qxp 12/16/2013 7:05 PM Page 1189 8L EVH Fluorescent Hand Lamps & Work Lights Dimensions In Inches: Work Light Hand Lamp (Magnetic Ballast Handlamps Only) 8L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1189 1190-1191.qxp 12/16/2013 7:05 PM Page 1190 8L 8L 1190 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1190-1191.qxp 12/16/2013 7:05 PM Page 1191 Exit Signs and Emergency Luminaires Hazardous and Non-hazardous 9L Description Page No. Exit Signs EXL Series EVLPF(B)-EXD DMVF(B)-EXD Ex-Lite CCH UX Series see pages 1192–1193 see page 1194 see page 1195 see page 1207 see page 1208 Light-Pak™ – Emergency Lighting Systems ELPS Series N2LPS Series see page 1196 see pages 1198–1200 Remote Luminaire Heads EVLA N2RF see page 1196 see pages 1198–1200 Compact Fluorescent Emergency Luminaires CPMVFB DMVFB EVLPFB see pages 1201–1202 see pages 1203–1204 see pages 1205–1206 9L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1191 1192-1193.qxp 12/16/2013 9L 7:06 PM Page 1192 EXL Explosionproof Exit Sign Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone 1 IIB Cl. II, Div. 1, Groups E, F, G Factory-sealed Applications: Ordering Information: EXL Exit Signs are used: • In locations deemed hazardous due to the presence of flammable vapors or gases, or combustible dusts • In any building or enclosed area where people work – where illuminated exit signs are required • To provide distinct, highly visible exit marking • To indicate the direction of travel to exits When ordering an EXL Series Exit Sign, you will need to specify: (A) Voltage (120VAC or 120VDC) (B) Mounting (Wall, End Bracket, or Pendant) (C) Exit Sign Designation All units come standard with 3/4" hubs and exit signs with red lettering and white background. Complete catalog numbering is as follows: Lamp Wattage: EXL (A) 2 (B) (C) (A) Voltage: 120VAC ............ leave blank 120VDC .......................... D (B) Mounting: Wall................................. 1 End Bracket.................... 2 Pendant .......................... 3 (C) Exit Sign Designation: A Single Face (Wall Mount) AA Double Face (End Bracket & Pendant) AB Double Face, one side arrowhead right, the other no arrowhead (End Bracket & Pendant) AC Double Face, one side arrowhead left, the other no arrowheads (End Bracket & Pendant) AD Double Face, one side arrowhead both ends, the other no arrowheads (End Bracket & Pendant) B Single Face, arrowhead right (Wall Mount) BC Double Face, one side arrowhead right, the other arrowhead left (End Bracket & Pendant) BD Double Face, one side arrowhead both ends, the other arrowhead right (End Bracket & Pendant) C Single Face, arrowhead left (Wall Mount) CD Double Face, one side arrowhead both ends, the other arrowhead left (End Bracket & Pendant) D Single Face, arrowhead both ends (Wall Mount) DD Double Face, both sides arrowhead both ends (End Bracket & Pendant) • Two 60 watt, 60T10 clear lamps for AC units • Two 25 watt, 25T10 clear lamps for DC units • Lamps not included with luminaire Mounting Type Sign Panel Description Hub Size (In.) AC Cat. # DC Cat. # Wall End Bracket Pendant Single face Double face Double face 3 Electrical Ratings: /4 /4 3 /4 EXL21A EXL22AA EXL23AA EXLD21A EXLD22AA EXLD23AA Features: • Two incandescent lamps (not included) wired in parallel – to provide extra margin of light source reliability • Solid state circuit for extended lamp life in AC units • Six inch red letters on white acrylic sign panel make word "exit" stand out boldly and clearly • Edge lighting characteristic of sign panel makes visibility excellent at all lighting levels • Factory-sealed explosionproof housing • Pendant, wall, and end bracket mounts provide universal installation options • Impact-resistant acrylic sign panel needs no guard – makes cleaning easy • Internal rectifier extends lamp life beyond 1,000-hour rated life – reduces relamping cost • Relamping tool provided 9L Certifications and Compliances: • NEC: Class I, Groups C, D Class II, Groups E, F, G • UL Standard: 844 • NFPA Life Safety Code No. 101-1991 Standard Materials: • Body – copper-free aluminum • Sign panel – acrylic Conduit Entrance: • 3/4" hubs • 120VDC or 120VAC operation Temperature Performance Data: (for both AC & DC operation): Ambient Temp. (°C) 25 40 1192 Class I (C, D) Class II (E, F, G) Supply Wire °C T3C T3C 150°C www.crouse-hinds.com US: 1-866-764-5454 Pendant Style End Bracket Style Wall Style 3 Options: Description Suffix Exit signs with green lettering on white background........................................................ GN Unit provided with epoxy powder coat............................................................................. S752 277VAC – (Order ECT413 Transformer Separately) CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1192-1193.qxp 12/16/2013 7:06 PM Page 1193 EXL Explosionproof Exit Sign 9L Factory-sealed Dimensions Dimensions In Inches: Wall Style Pendant Style 9L End Bracket Style www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1193 1194-1195.qxp 9L 12/16/2013 7:06 PM Page 1194 Cl. I, Div. 1, Groups B (suffix GB), C, D Cl. I, Zone 1, Groups IIB + H2 (GB suffix), IIB Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence EVLPF(B) – Exit Sign Fluorescent Luminaire Applications: EVLPF(B)-EXD Exit Signs are used: • In any building or enclosed area where people work – where illuminated exit signs are required • To provide distinct, highly visible exit marking • To indicate the direction of travel to exits • In locations deemed hazardous due to the presence of flammable vapors, gases, or combustible dusts Features and Benefits: • Six inch red letters on white glass sign panel make the word "EXIT" stand out boldly and clearly • Lightweight copper-free aluminum housing with powdered epoxy finish • All exterior hardware is corrosionresistant stainless steel • Three mounting arrangements: pendant, ceiling, and wall bracket • Integral ballast • High power factor (90%+) ballasts • Easier assembly, installation, and maintenance • Outdoor, hose down, marine and corrosive environments suitable • Ideal for adverse environments typical of industrial facilities • Ground wire for safety • Optional battery back-up for operation during power outage Marine & Wet Locations 3, 3R, 4, 4X; IP66 Certifications and Compliances: • NEC and CEC: Class I, Division 1, Groups B (GB suffix), C, D Class I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 Standard Materials: • Mounting modules, cover, ballast housing, globe holder – copper-free aluminum • Globe – heat- and impact-resistant glass • Exterior hardware – stainless steel Ratings (Electrical/Size): Sources/wattage: • 52W (2-26W lamps) • 120-277V, 50-60 Hz • 120V, 60 Hz • 347V, 60 Hz Conduit entries: • 3/4", 1" NPT – pendant, wall bracket, ceiling Standard Finishes: • Copper-free aluminum – Corro-free™ powdered epoxy Options: Description Group B suitability Factory assembled with lamps Suffix GB FA 9L About the Battery: • Bodine fluorescent battery pack ballasts are UL component recognized • Sealed, maintenance-free, high temperature nickel cadmium • Solid state chargers are sealed inside the ballast case • 90 minute illumination time • 10-year life expectancy • 2-year full warranty • During emergency use 1 lamp has continuous operation • Red indicator light indicates the battery is charging • Wiring instructions for a "Push-to-Test" button is supplied with the luminaire Ordering Information: Supply Mounting Voltage Type Volts/Hertz Fluorescent Cat. # Pendant 120–277V / 50–60 Hz EVLPFA02520/UNV EXD EVLPFBA02520/UNV EXD 120V / 60 Hz (Canada) EVLPFBA02520/120CAN EXD 347V / 60 Hz EVLPFA02520/347 EXD EVLPFBA02520/347 EXD Ceiling 120–277V / 50–60 Hz EVLPFCX02520/UNV EXD EVLPFBCX02520/UNV EXD 120V / 60 Hz (Canada) EVLPFBCX02520/120CAN EXD 347V / 60 Hz EVLPFCX02520/347 EXD EVLPFBCX02520/347 EXD Wall 120–277V / 50–60 Hz EVLPFBX02520/UNV EXD EVLPFBBX02520/UNV EXD 120V / 60 Hz (Canada) EVLPFBBX02520/120CAN EXD 347V / 60 Hz EVLPFBX02520/347 EXD EVLPFBBX02520/347 EXD Energy Savings: • Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output 1194 www.crouse-hinds.com US: 1-866-764-5454 Fluorescent with Battery Back-up Cat. # CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1194-1195.qxp 12/16/2013 7:06 PM Page 1195 DMVF(B) – Exit Sign Fluorescent Luminaire Applications: DMVF(B) Exit Signs are used: • In any building or enclosed area where people work • Where illuminated exit signs are required • To provide distinct, highly visible exit markings • To indicate the direction of travel to exits • In locations deemed hazardous due to the presence of flammable vapors or gases, or combustible dusts Features: • Six inch letters on white glass sign panel make the word "exit" stand out boldly and clearly • Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion • Mounting module equipped with integral hub set-screws for vibration resistance (ceiling and pendant mounts) • Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation • Epoxy powder finish and stainless steel external hardware for resistance to corrosion • Long life gaskets which provide seals between mounting module, housing, and globe assembly • Grounding wire for safety • Cool operating design • Optional emergency battery back-up operation during power outage About the Battery: Energy Savings: • Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output Cl. II, Groups E, F, G, Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4X; IP66 9L Certifications and Compliances: • NEC and CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 • IEC: Zone 2 Ex nR IIC • UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Luminaires • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 Standard Materials: • Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%) • Exterior hardware – stainless steel • Globe – heat- and impact-resistant internally fluted glass Standard Finishes: • Aluminum – gray epoxy powder coat • Krydon material – high reflectance white • Stainless steel – natural Options: Description Suffix Lamps supplied with exit sign............................................... S714 Top hat with stainless steel threaded insert.......................... S806 Restricted breathing construction.......................................... S826 Class I, Division 2 & Zone 2 suitability Cooler operating temperatures (T-Numbers) Certified for IEC Zone 2......................................................... S826TB Furnished with: Terminal Block Crimp Terminals Dedicated voltage ballasts (no MT, DT or TT) 9L • Bodine fluorescent battery pack ballasts are UL component recognized • Sealed, maintenance-free, high temperature nickel cadmium • Solid state chargers are sealed inside the ballast case • 90 minute illumination time • 10-year life expectancy • 2-year full warranty • During emergency use 1 lamp has continuous operation • A red indicator light indicates the battery is charging • Wiring instructions for a "Push-to-Test" button is supplied with the fixture Cl. I, Div. 2; Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Electrical Rating Ranges: • • • • 52 Watt 120–277V, 50–60 Hz 120V, 60 Hz 347V, 60 Hz Ordering Information: Mounting Type Supply Voltage Volts/Hertz Fluorescent Cat. # Pendant 120–277V / 50–60 Hz 120V / 60 Hz (Canada) 347V / 60 Hz DMVF2C052G/UNV EXD Ceiling 120–277V / 50–60 Hz 120V / 60 Hz (Canada) 347V / 60 Hz Wall 120–277V / 50–60 Hz 120V / 60 Hz (Canada) 347V / 60 Hz DMVF2TW052G/UNV EXD DMVFB2TW052G/UNV EXD DMVFB2TW052G/120CAN EXD DMVF2TW052G/347 EXD DMVFB2TW052G/347 EXD www.crouse-hinds.com US: 1-866-764-5454 DMVF2A052G/UNV EXD Fluorescent with Battery Back-up Cat. # DMVF2A052G/347 EXD DMVF2C052G/347 EXD CAN: 1-800-265-0502 DMVFB2A052G/UNV EXD DMVFB2A052G/120CAN EXD DMVFB2A052G/347 EXD DMVFB2C052G/UNV EXD DMVFB2C052G/120CAN EXD DMVFB2C052G/347 EXD Copyright© 2013 Eaton’s Crouse-Hinds Business 1195 1196-1197.qxp 12/16/2013 9L 7:06 PM Page 1196 ELPS Light-Pak™ Emergency Lighting System Applications: ELPS Series Emergency Lighting Systems are used: • To provide safe, reliable illumination indoors or outdoors to designated areas during failure or interruption of power to the normal lighting system • In areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitible fibers and flyings • In areas where corrosion, vibration, moisture, dirt, and rough usage may be encountered • Where required by the National Electrical Code®, the Life Safety Code, or other codes • In refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants, wastewater treatment facilities, and other areas where safe, reliable, hazardous area emergency lighting is needed 9L Features: • Compact factory-sealed luminaire assemblies are each furnished with a 12 watt tungsten-halogen lamp and inner reflector for appropriate photometrics in hazardous areas • Luminaire assemblies are fully adjustable and lockable on two axes to provide flexible and consistent light aiming capabilities • Luminaire lens ring is threaded for easy relamping and locks in place with hex head set-screw; will not loosen due to vibration • Ground joint cover with external flange design permits large opening and easy access to internal components; stud bolts in diagonally opposite corners of body ease cover removal and installation • Neoprene cover gasket seals out moisture for superior protection of internal components against wetness and corrosion • Lightweight, compact size, and mounting feet ease installation and allow placement in confined areas • Two 1" NPT drilled and tapped conduit openings, with plugs, are standard, for choice of top or bottom feed • Factory-installed PUSH-TO-TEST pushbutton enables easy testing of system • MAIN POWER ON pilot light indicates AC power is being supplied to the battery charger; pilot light jewel is threaded for easy lamp replacement • Stainless steel drain minimizes moisture collection; stainless steel breather with aluminum cap provides ventilation, minimizes moisture collection Cl. I, Div. 1 & 2, Groups C, D Cl. I, Div. 1 & 2, Groups B, C, D (with suffix GB) Cl. II, Div. 1, Groups E, F, G Cl. III • CID 101 corrosion inhibitor device is provided with each ELPS system to help protect electrical components and connections • Rugged, long-life, maintenance-free, nickel cadmium battery provides 30 watts of power for the required 11/2 hours • Solid state battery charger for long life and reliable service prevents deep discharge by automatically disconnecting luminaires from battery • Terminal block facilitates field wiring connections • Instruction sheet and maintenance record card provided with unit in a protective plastic envelope • A time delay is standard; time delay is preset at factory for 5 minute delay but can be field set for 5 seconds or 15 minutes, thus allowing HID type lamps time to restrike and reach desired illumination levels • Solid state battery charger will accept 120, 220/240 or 277 VAC, 50/60 Hz Certifications and Compliances: • NEC: Class I, Groups B, C, D Class II, Groups E, F, G Class III Simultaneous Presence • NEMA: 3R, 12 (ELPS power supply) • Suitable for wet locations (EVLA fixtures) • Marine (EVLA fixtures) • UL Standard: 844 – Electric Luminaire – Hazardous Locations 924 – Emergency Lighting and Power Equipment 1203 – Explosionproof and DustIgnitionproof Electrical Equipment • Life Safety Code: Section 5-9 (Emergency Lighting) • Suitable for Wet Locations • NEMA 3, 3R, 12 • Marine Standard Materials: • Power supply enclosure and luminaire assembly – copper-free aluminum (less than 0.4 of 1% copper) Standard Finishes: • Power supply enclosure and fixture assemblies – powder coat epoxy paint finish Electrical Ratings: • Power Supply: Input: 120, 220/240, 277 VAC, 50 or 60 Hz 0.5 Amps Maximum Output: 12 VDC UL listed for 28 watts for 11/2 hours at 0° – 40°C • Luminaires: Voltage: 12 VDC Lamp Type: #789, miniature Tungsten halogen, G4, 2-pin, 14 watt Options: Description Suffix • Remote mounted lamp head and arm .... EVLA12 • Key operated disconnect switch as part of the ELPS502 emergency light system .......................... S794 • Keyless operated designated disconnect switch as part of the ELPS502 emergency light system .......... S854 Ordering Information: Description www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Cat. # • Standard unit with ELPS502† adjustable heads............ • Replacement power interior, includes circuit ELPS K50 board and battery pack • Power supply ................. ELPS50† • Lamphead and arm ....... EVLA12† • Exit sign, double sided ELPS502 EXD with EVI, red letters........ • Exit sign, double sided ELPS502 EXD GN with EVI, green letters.... • Exit sign, single or double sided with Group B EVA, ELPS502 EXD GB red letters....................... • Exit sign, single or double sided with Group B EVA, green letters ............................. ELPS502 EXD GB GN • Exit sign, single sided with EVI, red letters........ ELPS502 EXS • Exit sign, single sided with EVI, green letters ................... ELPS502 EXS GN †Base unit comes standard with Class I, Division 1, Group B. 1196 Cl. I, Zone 1 Simultaneous Presence Wet Locations NEMA 3, 3R, 12 Copyright© 2013 Eaton’s Crouse-Hinds Business 1196-1197.qxp 12/16/2013 7:06 PM Page 1197 ELPS Light-Pak™ Emergency Lighting System Temperature Performance Data Photometric Data Dimensions and Weights Temperature Performance Data: Cat. # Class Maximum Ambient Temperature 55°C I II* EVLA12 III* 9L Photometric Data: T-number T4A T3B T3B Maximum Ambient Temperature 40°C ELPS EVI ELPS EVA T3C T4 T3C T4 *For Class II and Class III applications, fixtures must not be aimed more than 30° above horizontal (see diagram below). Dimensions In Inches: 9L Unit Net Weights: • ELPS502 complete emergency lighting system – 50 lbs. • ELPS50 power supply – 40 lbs. • EVLA12 luminaire assembly – 5 lbs. Status Indication: LED Status Meaning of the Indication AC power is removed from the circuit • Steady light (no blinking) Fully charged • Light blinks once Charging •• Light blinks twice Battery failure Light blinks three times Light blinks four times Circuit failure Lamp failure ••• •••• www.crouse-hinds.com Condition No light US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1197 1198-1199.qxp 12/16/2013 7:06 PM Page 1198 N2LPS LIGHT-PAK™ Emergency Lighting System 9L Applications: LED N2LPS Light-Pak™ emergency lighting systems are used: • To provide reliable illumination for egress areas during failure or interruption of power to the normal lighting system • In areas where flammable gases or vapors may become present due to abnormal, unusual, or accidental conditions • In manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, oil terminals, food processing facilities, breweries, and other industrial manufacturing or process industry facilities subject to wet or corrosive conditions • To illuminate machinery or panels during a loss of AC power • Where moisture, dirt, dust, or corrosion will limit the life and reliability of ordinary emergency lighting systems • Where required by the National Electrical Code®, the Life Safety Code® or other applicable codes • Outdoor applications 9L Features: • Compact, factory-assembled luminaire featuring LED lamps for improved lumen performance, on-time, and lamp life • Nonmetallic, enclosed, and gasketed housing provides corrosion protection in the most extreme environments • Durable and marine rated LED lamp head assemblies provide protection against water ingress, corrosion, and impact • High temperature rated nickel cadmium battery for reliable operation up to 55ºC ambient • Solid state battery charger for long life and reliable battery operation prevents deep discharge by automatically disconnecting the battery from the luminaire • Factory-installed "push-to-test" button • Self-test, monitoring, and diagnostics reduce costly maintenance checks • Remote luminaire head assemblies (one or two) are available for mounting of luminaire heads away from main power system • Stainless steel drain minimizes moisture collection • Standard battery disconnect switch (Krydon® unit) 1198 www.crouse-hinds.com US: 1-866-764-5454 Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0ºC to 55ºC Certifications and Compliances: NEC/CEC: • Class I, Division 2, Groups B, C, D, Zone 2 UL Standards: • 1598A (Supplemental Requirements for Luminaires for Installation on Marine Vessels) • 924 (Emergency Lighting and Power Equipment) • 844 (Electric Luminaires Hazardous Locations) CSA Standards: • C22.2 No. 141-M1985 unit equipment for emergency lighting • C22.2 No. 137-M1981 non-incendive electrical equipment for use in Class I, Division 2 hazardous locations • Life Safety Code NFPA101® – Section 5-9 (Emergency Lighting) • Marine wet locations suitability, Type 4X Standard Materials: • Power supply and remote luminaire enclosures – Krydon® fiberglassreinforced polyester • LED lamp head assembly – epoxy powder coated stainless steel • Exterior hardware – nylon, plastic coated, and stainless steel • Cover gasket – Hypalon® synthetic rubber Temperature Performance Data: Based on 55°C ambient Class I, Cat. # Division 2 N2LPS (all) N2RF (all) 40ºC - T5; 55ºC - T4A T5 Class II, Division 1 Electrical Ratings: • Power supply – Input: 120, 220, 230, 240, or 277 VAC, 50 or 60 Hz; 9 watts max. Output: 18 watts max. at 12 VDC • Luminaire heads – Voltage: 12 VDC; Lamp: 3 watt LED Total lumen output: 80 Unit Net Weights: • • • • N2LPS12222 – 16 lbs. N2LPS12220 – 12 lbs. N2RF1221 – 8 lbs. N2RF1222 – 9 lbs. Options: Description Suffix 55°C suitability . . . . . . . . . . . . . . . . . S904 T6 T6 Note: Ambient temperature at which the Light-Pak system is rated is 0°C to 55°C. Operation at temperatures outside this range will affect the battery life and/or charging performance. Note: Battery time in emergency mode is 90 minutes. National Electrical Code and Life Safety Code are registered trademarks of the National Fire Protection Association, Inc. Noryl is a registered trademark of General Electric Company. CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1198-1199.qxp 12/16/2013 7:06 PM Page 1199 N2LPS LIGHT-PAK™ Emergency Lighting System 9L Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0ºC to 55ºC Ordering Information: Description Cat. # 28 watt, 12 volt power supply assembly with two 3 watt LED lamp heads 28 watt, 12 volt stainless steel power supply assembly with two 3 watt LED lamp heads 28 watt, 12 volt power supply assembly less luminaire heads Remote luminaire assembly with one 3 watt LED lamp head Remote luminaire assembly with two 3 watt LED lamp heads 28 watt, 120V LED Light-Pak with single sided exit sign** 28 watt, 277V LED Light-Pak with single sided exit sign** 28 watt, 120V LED Light-Pak with double sided exit sign** 28 watt, 277V LED Light-Pak with double sided exit sign** N2LPS12222 N2LPS12222 SS N2LPS12220* N2RF1221* N2RF1222* N2LPS12222/120 N2LPS12222/277 N2LPS12222/120 N2LPS12222/277 EXS DR0391734 EXS DR0391734 EXD DR0391734 EXD DR0391734 *Not cUL approved. UL Listed only. **Exit sign operates in both normal and emergency mode. Note: Up to four (4) remote LED lamp assemblies can be connected to the N2LPS12222. Up to six (6) remote LED lamp assemblies can be connected to the N2LPS12220. Wire Sizing for Remote Installation: For Copper Wire – Running Distance† (ft.) Between Power Supply and Remote Luminaire Load In Watts Load In Watts Wire Size 8 16 24 32 Wire Size 8 16 24 32 16 AWG 14 AWG 12 AWG 26 42 66 13 21 33 6 10 16 3 5 8 10 AWG 8 AWG 6 AWG 106 168 270 53 84 135 26 42 67 13 21 33 †Maximum distance to limit line voltage drop to 5%. Dimensions (N2LPS): 1.1 13.5 9L 16.0 7.5 5.0 13.8 14.5 7.4 18.0 Standard – N2LPS LED Light-Pak™ www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1199 1200-1201.qxp 12/16/2013 7:07 PM Page 1200 N2LPS LIGHT-PAK™ Emergency Lighting System 9L Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 2 Cl. II, Div. 2, Groups F, G Wet Locations, Marine NEMA 3, 3R, 4X Ambient 0ºC to 55ºC Dimensions (N2LPS): EXS, EXD Option – N2LPS LED Light-Pak™ with Optional Emergency Exit Luminaire Dimensions (N2RF): 9.50 9L 9.50 3.83 3.83 7.27 4.38 11.77 Detail Indication Logic: Status Indication Status Description Status Definition * *-* **-** ***-*** No Light Steady Light (No Blinks) Light Blinks Once Light Blinks Twice Light Blinks Three Times AC Power Removed from Circuit Fully Charged Battery Charging Battery Failure Circuit Failure 1200 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1200-1201.qxp 12/16/2013 7:07 PM Page 1201 CPMVFB Emergency Compact Fluorescent Continuous Operation Champ-Pak™ Luminaires Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence* Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting Applications: Standard Materials: • Where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures • Where emergency egress lighting is required, such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps and aisles • Indoor and outdoor wall mounting or vertical surface mounting where minimal luminaire depth is required in: – Manufacturing plants and heavy industrial facilities – Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical, and platforms – Waste or sewage treatment plants – Offshore, dockside, and harbor installations • For security and safety lighting in industrial facilites for lighting of loading docks, tunnels, and stairways • For marine, wet location, hose down, and corrosive environments • Luminaire housing and door frame assembly – copper-free aluminum • External hardware – stainless steel • Lens – heat- and impact-resistant refractor style glass • Gaskets – silicon rubber • Reflector – aluminum light sheet • Wire guard – stainless steel Features and Benefits: Certifications and Compliances: • NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 • IEC: Zone 2 Ex nR IIC • UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 Standard Finishes: • Aluminum – Corro-free™ epoxy powder coat • Stainless steel – natural Options: Description Suffix Restricted breathing construction................................................................................. S826 Class I, Division 2 & Zone 2 suitability Cooler operating temperatures (T-numbers) Certified for IEC Zone 2 (Suffix S826TB)....................................................................... S826TB Furnished with: Terminal Block Crimp Terminals Dedicated voltage ballasts (no MT, DT or TT) Factory assembled with lamp installed......................................................................... FA Fused - projects ballast and capacitors against abnormal line conditions.................. S658 (Not for use in Canada) (Not for Marine use) Electrical Rating Ranges: • • • • 52 watts 120–277V, 50–60 Hz 120V, 60 Hz 347V, 60 Hz About the Battery: • • • • • • • • • 9L • Unique compact shallow profile design mounts virtually anywhere • Side hinged cover with two screw closing for easy installation and maintenance • Gray Corro-free™ epoxy powder coat two-piece housing provides superior corrosion resistance • Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance • Glass refractor provides uniform light distribution to eliminate glare • Silicon gaskets make luminaire suitable for NEMA 4X, marine enviroments • High power factor ballasts (+90%) are standard, which allow more luminaires per circuit 9L Bodine fluorescent battery pack ballasts are UL component recognized Sealed, maintenance-free, high temperature nickel cadmium Solid state chargers are sealed inside the ballast case 90 minute illumination time 10-year life expectancy 2-year full warranty During auxiliary use 1 lamp has continuous operation A red indicator light indicates the battery is charging Wiring instructions for a "Push-to-Test" button is supplied with the fixture Accessories: Description Stainless steel wire guard............................................................................................. Cat. # P55 *Consult Eaton's Crouse-Hinds. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1201 1202-1203.qxp 12/16/2013 7:07 PM Page 1202 CPMVFB Emergency Compact Fluorescent 9L Ordering Information Dimensions & Weights Continuous Operation Champ-Pak™ Luminaires Ordering Information: Hub Size Lamp Watts Cat. # for use with ANSI Lamps /4 NPT 26 CPMVFB2W026 3 Standard Voltage Ballasts NEC/UL 120–277V 50–60 Hz /UNV Voltage Suffix CEC/CSA (cUL) 120V/60 Hz 347V 60 Hz /120CAN /347 Dimensions 9L In Inches: Net Weights: Luminaire Less Guard P55 Guard 1202 www.crouse-hinds.com 18.6 lbs. 0.5 lbs. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1202-1203.qxp 12/16/2013 7:07 PM Page 1203 DMVFB Emergency Compact Fluorescent Continuous Operation Champ® Luminaires Applications: DMVF Series Champ Lighting Luminaires are used: • Where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures • Where emergency egress lighting is required, such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps, and aisles • In areas made hazardous by abnormal conditions resulting in the presence of flammable vapors or gases • In areas made hazardous by the presence of combustible dusts • Where combustible dusts and flammable vapors are present simultaneously • In marine applications where water spray and corrosive atmospheres are considerations • On installations where vibration and rough usage are problematic • Where a cool, efficient light source is required • In areas that require lamps to reach full illumination immediately • In refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants, wastewater treatment plants, sewage treatment plants, oil terminals, food processing facilities, breweries, and any other manufacturing or processing facility where safe, reliable hazardous area fluorescent or auxiliary lighting is needed • Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion • Mounting modules equipped with integral hub set-screws for vibration resistance (ceiling, pendant, and quad mounts) • Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation • Epoxy powder finish and stainless steel external hardware for resistance to corrosion • Long-life gaskets which provide seals between mounting module, housing, and optical assembly • Grounding wire for safety • Cool operating design • Optional stainless steel open bottom guard permits direct access to the globe for easy relamping • Battery pack ballast for emergency lighting Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting 9L Certifications and Compliances: • NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 Emergency Lighting • IEC: Zone 2 Ex nR IIC • UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations 924 Emergency Lighting • CSA Standards: C22.2 No. 137 • IEC Standards: 60079-15 Standard Materials: • Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%) • External hardware guards – stainless steel • Reflectors – Krydon® fiberglassreinforced polyester material • Globe – heat- and impact-resistant internally fluted glass Standard Finishes: • Aluminum – gray epoxy powder coat • Krydon material – high reflectance white • Stainless steel – natural Options: Description Suffix • Restricted breathing construction................................ S826 -Class I, Division 2 & Zone 2 suitability -Cooler operating temperatures (T-numbers) • Certified for IEC Zone 2............. S826TB -Furnished with: Terminal Block Crimp Terminals • Emergency operation only – Consult Eaton's Crouse-Hinds • Factory assembled with lamp installed....................................... FA • Fused – to protect ballast against abnormal line conditions (not for use in Canada) (not for marine use).................................. S658 • Lamps supplied with luminaire... S714 • Top hat with stainless steel threaded insert to attach ballast housing........................................ S806 • TEFLON® coating on globe for increased shatter protection....... S808 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Electrical Rating Ranges: • 52, 64, and 84 watts • 120–277V, 50–60 Hz • 347V, 60 Hz Accessories: (Order separately) Description Cat. # Dome 30° Angle RD739 RA739 9L Standard Features: Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Energy Savings • Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output About the Battery (DMVFB Units): • Bodine fluorescent battery pack ballasts are UL component recognized • Sealed, maintenance-free, high temperature nickel cadmium • Solid state chargers are sealed inside the ballast case • 90 minute illumination time • 10-year life expectancy • 2-year full warranty • During auxiliary use 1 lamp has continuous operation • A red indicator light indicates the battery is charging • Wiring instructions for a "Push-to-Test" button is supplied with the fixture Copyright© 2013 Eaton’s Crouse-Hinds Business 1203 1204-1205.qxp 9L 12/16/2013 7:09 PM Page 1204 DMVFB Emergency Compact Fluorescent Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Continuous Operation Champ® Luminaires Mounting Style Pendant Mount /4 1 3 /4 1 3 /4 1 52 /4 /4 3 /4 52 64 84 DMVFB2HA052GP DMVFB2HA064GP DMVFB2HA084GP /4 1 3 /4 1 3 /4 1 52 DMVFB2C052GP DMVFB3C052GP DMVFB2C064GP DMVFB3C064GP DMVFB2C084GP DMVFB3C084GP /4 1 3 /4 1 3 /4 1 52 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121/ 2° Angle 3 /4 /4 3 /4 52 64 84 DMVFB25Q052GP DMVFB25Q064GP DMVFB25Q084GP Stanchion Mount 25° Angle 11/2 11/2 11/2 52 64 84 DMVFBJ052GP DMVFBJ064GP DMVFBJ084GP Stanchion Mount Straight 11/ 2 11/ 2 11/ 2 52 64 84 DMVFBP052GP DMVFBP064GP DMVFBP084GP Flexible Pendant Mount 3 Ceiling Mount Thru-Feed 3 Wall Mount Thru-Feed 9L DMVFB Series Fluorescent with Battery Back-Up with G303 Globe and P33 Guard Cat. # DMVFB2A052GP DMVFB3A052GP DMVFB2A064GP DMVFB3A064GP DMVFB2A084GP DMVFB3A084GP Hub Lamp Size (In.) Watts 3 3 3 3 64 84 64 84 DMVFB2TW052GP DMVFB3TW052GP DMVFB2TW064GP DMVFB3TW064GP DMVFB2TW084GP DMVFB3TW084GP 64 84 Note: For technical information on family trees, temperature performance data, dimensions, weights, and photometrics, refer to Series in Section 5L. 1. Catalog numbers are basic numbers. Voltage must be specified. Standard Voltage Ballasts NEC/UL 1. Voltage Suffix 1204 120–277V 50–60 Hz /UNV www.crouse-hinds.com US: 1-866-764-5454 Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting CEC/CSA (cUL) 120V/60 Hz /120CAN CAN: 1-800-265-0502 347V 60 Hz /347 Copyright© 2013 Eaton’s Crouse-Hinds Business 1204-1205.qxp 12/16/2013 7:09 PM Page 1205 EVLPFB Emergency Compact Fluorescent Continuous Operation Low Profile Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting 9L Applications: Eaton's Crouse-Hinds Low Profile Hazard•Gard® Luminaires are used in: • Areas that require lamps to reach full lumination immediately • Where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures • Where emergency lighting is required such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps, and aisles • Areas where flammable or explosive vapors or gases are present • Hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired • Petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities • Waste treatment facilities • Drilling platforms and other coastal and offshore hazardous areas Features and Benefits: Certifications and Compliances: • NEC/CEC: Class I, Division 1, Groups B (with GB suffix), C, D Class I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) Emergency Lighting • UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations 924 Emergency Lighting • CSA Standards: C22.2 No. 137 Ratings (Electrical/Size): • Mounting modules, cover, ballast housing, globe holder – copper-free aluminum • Globe – heat- and impact-resistant glass • Exterior hardware – stainless steel • Reflectors (dome & angle) – Krydon® fiberglass-reinforced polyester Sources/Wattage: • Fluorescent continuous operation emergency lighting 52W (2-26W lamps) and 64W (2-32W lamps) compact fluorescent voltages • Fluorescent emergency lighting 120–277V, 50–60 Hz 120V, 60 Hz 347V 60Hz Conduit entries: • 3/4", 1" NPT – pendant, wall bracket, ceiling • 11/4" NPT – stanchion Standard Finishes: • Copper-free aluminum – Corro-free™ powdered epoxy • Krydon – white • Stainless steel guard Energy Savings • Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output Options: Description Group B suitability Fused (not for use in Canada) (not for marine use) Factory assembled with lamps Emergency operation only – Consult Eaton's Crouse-Hinds Suffix GB S658* FA 9L • Small, compact size • Two start Acme threaded construction • Easier assembly, installation, and maintenance • Lightweight copper-free aluminum housing with powdered epoxy finish • All exterior hardware is corrosionresistant stainless steel • Four mounting arrangements: pendant, ceiling, wall bracket, and stanchion • Integral ballast • High power factor (90%+) ballasts • Uses same mounting modules as the standard Hazard•Gard® • Internally fluted glass globes • Krydon® construction dome and angle reflectors – won't rust, corrode, dent, chip, or peel • Now available in components – luminaire body, mounting module, guard, reflectors • Three wire construction • For energy conservation, luminaires can be switched off without affecting the emergency operation feature Standard Materials: *When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Accessories: Description Cat. # Dome reflector Angle reflector RD739 RA739 About the Battery: • Bodine fluorescent battery pack ballasts are UL component recognized • Sealed, maintenance-free, high temperature nickel cadmium • Solid state chargers are sealed inside the ballast case; 90 minute illumination time; 10-year life expectancy • 2-year warranty • During emergency use, 1 lamp has continuous operation • A red indicator light indicates the battery is charging • Wiring instructions for a "Push-to-Test" button is supplied with the fixture www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1205 1206-1207.qxp 9L 12/16/2013 7:09 PM Page 1206 EVLPFB Emergency Compact Fluorescent Continuous Operation Low Profile Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence Marine & Wet Locations 3, 3R, 4, 4X; IP66 Emergency Lighting Ordering Information: Pendant Mount Pendant Wall Bracket† Hub Size With Guard With Guard Watt (In.) Cat. # Cat. # Fluorescent with Emergency Ballast – High Power 3 /4 EVLPFBA02521 EVLPFBBX02521 EVLPFBA03521 EVLPFBBX03521 52W 1 11/4 3 /4 1 11/4 64W EVLPFBA02641 EVLPFBA03641 EVLPFBBX02641 EVLPFBBX03641 Ceiling† Stanchion With Guard With Guard Cat. # Cat. # Factor Ballast (Min. P.F. 90%) EVLPFBCX02521 EVLPFBCX03521 EVLPFBJ04521 EVLPFBCX02641 EVLPFBCX03641 Luminaire Body Less Mounting Module & Guard Cat. # EVLPFB0520 EVLPFB0640 EVLPFBJ04641 Complete Catalog Numbers as follows: Standard Voltage Ballasts NEC/UL 1. Voltage 120–277V 50–60 Hz /UNV Suffix 2. Wall Bracket Mount† CEC/CSA (cUL) 120V/60 Hz /120CAN 347V 60 Hz /347 Example: EVLPFB02521/UNV Other Voltages – Consult Eaton's Crouse-Hinds Note: For technical information on family trees, temperature performance data, dimensions, weights, and photometrics, refer to DMVF Series in Section 5L. EVFPFB Fluorescent Emergency Lighting 9L • Three wire construction, for switching purposes, is standard on fluorescent emergency lighting. • For energy conservation, luminaires can be switched off without affecting the emergency operation feature. Ceiling Mount† *Test switch is remote mounted. Use Eaton's Crouse-Hinds EDSC218 (not furnished). Stanchion Mount †Ceiling and bracket mounts have 4 hubs: 3 are plugged. 1206 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1206-1207.qxp 12/16/2013 7:09 PM Page 1207 Ex-Lite LED Exit Signs Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 1, AEx em ib IIC (NEC) Cl. I, Zone 1, Ex em ib IIC (CEC) Cl. II, Div. 2, Groups F, G (NEC) Cl. II, Div. 2, Groups E, F, G (CEC) 9L UL Listed IP66 The Ex-Lite Series of LED exit signs are designed for hazardous locations and are ideally suited for marking escape routes and exits in potentially explosive atmospheres. The Ex-Lite Z is available as an AC only version, while the Ex-Lite ZE is available with self-contained battery. As an emergency lighting luminaire with selfcontained battery system, the Ex-Lite ZE features a nickel cadmium battery with automatic test and monitoring feature. Applications: • In harsh and hazardous environments where illuminated exit signs are required Features and Benefits: Ordering Information: Catalog Number Material Number Description Ex Lite Z 12191001005 AC/DC Exit Sign Ex Lite ZE 12191130005 with Battery Light Source Life of LED Rated Voltage, VAC Frequency, Hz Rated Voltage, DC Power Consumption Battery LED 50K hours 120V-277V 50/60 110V-250V 6VA N/A -4ºF to 122ºF (-20ºC to 50ºC) Wall Ex-e 3 /4" IP66 LED 50K hours 120V-277V 50/60 110V-250V 6VA NiCad 41ºF to 95ºF (5ºC to 35ºC)* Wall Ex-e 3 /4" IP66 Allowable Temperature Range Mounting Cable Entry Conduit Entry Protection 9L LED Technology: • Long life (>50K hours) for years of maintenance-free operation • Energy-efficient for lower cost of operation • Low temperature operation with no loss of illumination • Rugged and durable light source for the harshest of environments Exit Sign System: • Can be used in a hazardous location • Conduit or cable entry • Can be installed in moist, humid, rain, and wet environments • Universal input voltage 110VAC-277VAC and 110VDC-250VDC reduces inventory • Ex-Lite ZE with self-monitoring, selfdiagnostic, and test capability • Premium heavy-duty nickel cadmium battery • 24-hour charge and recharge time increases safety by recovering quickly from outage • "EXIT" legend with alternative wings left, right, or left and right; simple field modification • Emergency lighting cycle three hours • The housing of the luminaire is constructed with a corrosion resistant, robust, lightweight aluminum alloy material and illumination of the sign is provided with red, high-efficient LEDs *Due to battery chemistry, the charging capacity will be limited at temperatures below 5ºC and above 35ºC. Dimensions In (mm): Certifications and Compliances: • • • • • • • • • • Class I, Division 2, Groups A, B, C, D Class I, Zone 1, AEx em ib IIC (NEC) Class I, Zone 1, Ex em ib IIC (CEC) Class II, Division 2, Groups F, G (NEC) Class II, Division 2, Groups E, F, G (CEC) IP66 UL844 UL924/CSA22.2 No. 141-02 UL60079/CSA22.2 E60079 UL1203/CSA22.2 E6124-1-1-02 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1207 1208-1209.qxp 12/16/2013 9L 7:11 PM Page 1208 NEMA 4X, IP66 UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating CCH UX Series LED Exit Signs Eaton's Crouse-Hinds CCH UX Series LED Exit Sign combines the strength and durability of die cast aluminum with architecturallypleasing aesthetics. The CCH UX Series is illuminated by LEDs, providing the customer with a long-life, low maintenance, dependable exit sign for use in conditions where reliability is crucial. Designed for the most severe environments, the CCH UX Series will provide maximum performance against rain, moisture, cold, corrosion, and dust in applications such as manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, food processing, and other industrial facilities. Applications: • In locations deemed hazardous due to the presence of flammable vapors or gases • In areas where the presence of gases or vapors may become present during an abnormal, unusual, or accidental conditions • Outdoor and wet applications • Where required by the National Electrical Code®, Life Safety Code®, or other applicable codes 9L Features and Benefits: • Wet location, outdoor rated for use in the most demanding environments • Optional hazardous location rating available • Dual voltage 120V/277V reduces wiring errors • Heavy-duty nickel cadmium battery for long life • 24-hour charge and recharge recovery time increases safety • Heavy-duty injection molded polycarbonate lens protects against impact and corrosion • Brown-out protection protects battery and reduces labor • Heavy-duty aluminum die cast housing protects against impact and chemical resistance • LEDs provide long life, even illumination, and energy savings • Wide operating temperature range (-45°C to 45°C) • Self-diagnostic testing reduces costs by eliminating scheduled equipment verification tests • Heavy duty nickel cadmium battery for long life meets 90 minute requirements for battery operated emergency system Certifications and Compliances: • • • • NEMA 4X, UL50 UL924 wet location IP65, IP66 Available with NEC hazardous location rating - UL844 Class I, Division 2, Groups A, B, C, D In Inches: Mounting: wall mount, ceiling mount, end mount Conduit Entry: top, bottom, or either side of the unit www.crouse-hinds.com US: 1-866-764-5454 • Provides safe and reliable exit marking both indoors and outdoors during power failure or interruption of power to normal lighting system • Long life (>50K hours) for years of maintenance-free operation • Energy-efficient for lower cost of operation • Low temperature operation with no loss of illumination • Rugged and durable light source for the harshest of environments Temperature Performance Data: CCH UX Series Exit Sign: • -45ºC (-49ºF) to 45ºC (113ºF) CCH UX-HAZ Hazardous Location Exit Sign: • T6 rating at 45ºC (113ºF) Electrical Ratings: • Power Supply 120V/277V dual voltage • LED Exits - Red Input Power 120V = 2.7W 277V = 3.2W • LED Exits - Green Input Power 120V = 2.3W 277V = 3.0W Input Current: (Max.) 120V = .08A 277V = .03A Input Current: (Max.) 120V = .07A 277V = .04A Ordering Information: Dimensions 1208 Benefits of LED Technology: CAN: 1-800-265-0502 Catalog Number Housing Finish Letter Color CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH CCH Silver Housing Silver Housing Silver Housing Silver Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Silver Housing White Housing Black Housing Red LED Red LED Green LED Green LED Red LED Red LED Red LED Red LED Red LED Red LED Green LED Green LED Green LED Green LED Green LED Green LED UX70RSDHAZ UX60RHAZ UX70GSDHAZ UX60GHAZ UX70RSD UX70RWHSD UX70RBKSD UX60R UX60RWH UX60RBK UX70GSD UX70GWHSD UX70GBKSD UX60G UX60GWH UX60GBK Copyright© 2013 Eaton’s Crouse-Hinds Business 1208-1209.qxp 12/16/2013 7:11 PM Page 1209 Specialty Lighting 10L Tank, Task and Gauge Lighting Hazardous and Non-hazardous Locations Description Page No. Application/Selection see page 1210 Gauge Light see page 1216 Tank Light V160 EVA160 see page 1211 see page 1212 Task Light EVTL1B50 EVTL1L50 see pages 1213–1215 see pages 1213–1215 10L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1209 1210-1211.qxp 10L 12/16/2013 7:11 PM Page 1210 Specialty Lighting Tank, Task and Gauge Hazardous and Non-hazardous Locations Application and Selection Applications: Considerations for Selection: Environmental: • What is the hazardous area classification (NEC)/(CEC) of the location in which the luminaire will be installed? Lighting levels required: • What wattage luminaire(s) will provide the desired light level? Physical Arrangement: • Type of fixture mounting needed Product Selection: • EV Tank Lights are suitable for use in Class I, Groups C, D hazardous (classified) locations; tank lights are used to light the inside of tanks, vats, process vessels, etc. • EVTL Explosionproof Task Lights are suitable for use in Class I, Group B, C, D and Class II, Groups E, F, G hazardous (classified) locations; EVTL Lights are ideal for applications in which water spray and corrosive atmospheres are considerations • ELG Gauge Lights are suitable for use in Class I, Groups C, D hazardous (classified) location; the light is used to illuminate liquid level gauges and to direct the light over the length of the column 10L Specialty lighting luminaires are used: • For various task lighting requirements in locations that are hazardous (classified) due to the presence of combustible dusts or easily ignitible fibers and flyings • In areas where conventional lighting is not acceptable due to size and/or location • In locations where an adequate light source is necessary for tank, instrument, and gauge applications • In manufacturing plants, refineries, pharmaceutical, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, grain processing and handling facilities, and other heavy industrial applications 1210 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1210-1211.qxp 12/16/2013 7:11 PM Page 1211 V Observation Incandescent Luminaire 10L Watertight Applications: The incandescent V Observation Luminaire is used: • In tanks or kettles where food is processed • To light the inside of tanks for observation of the contents through a window Features: • Watertight • Supported by a mounting ring which contains holes for riveting when placed around a hole in the tank; it can also be welded or brazed to the tank • Heavy heat and impact-resistant glass globe eliminates breakage and resultant contamination of food from glass particles • Relamping is easily accomplished by removal of the two thumb-screws which fasten the body to the mounting ring • The flexible cord or cable should be connected by an EC flexible coupling or CG Series connector Certifications and Compliances: Furnished with EV10 Globle, and C166 Medium Base Lamp Receptacle Hub Lamp Size Size Cat. # 11/2" 50, 60, 75 or 100W, A-21 V160 Dimensions In Inches: • UL Standard: 1571 • CSA Standard: C22.2 Standard Materials: • Mounting ring – silicon bronze • Fixture body – Feraloy® iron alloy • Globe – heat-resisting glass 10L Standard Finishes: • Feraloy – electrogalvanized and aluminum acrylic paint • Bronze – natural Size Ranges: • Up to 100 watt, A-21 lamp www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1211 1212-1213.qxp 12/16/2013 10L 7:11 PM Page 1212 Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone I & 2, IIB Cl. II, Div. 1, Groups E, F, G – EVO only EV Tank Luminaires Applications: Temperature Performance Data: EV Tank Light Luminaires are used: • To light inside of tanks, vats, process vessels, etc. • In chemical plants, petrochemical plants and petroleum process industries • Suspended over tank porthole by EC flexible hanger (EVO style) • Mounted directly in tank wall (EVA) Based on 40°C Ambient Cat. # Class I, Groups C, D Class II, Groups E, F, G Supply Wire (°C) EVO2376 EVA160 T3C T3C* T3C — 75 75 *All mounting positions. Dimensions In Inches: Features: • High light output • Compact design EVA160: • Furnished with tank ring having eight 3/16" holes for riveting to tank • Can be brazed if desired • Luminaire ring is attached to the tank ring by eight 1/4-20 Allen Head cap screws • Luminaire attached to luminaire ring by four wing screws • EC flexible luminaire support should be used so relamping can be accomplished without disturbing the globe EVO2376 EVO2376 Certifications and Compliances: • NEC: Class I, Division 1 and 2, Groups C, D – EVO and EVA Class II, Division 1, Groups E, F, G – EVO only • UL Standard: 844 EVA160 10L Standard Materials: • Bodies – EVO: copper-free aluminum; EVA: receptacle housing and intermediate ring – Feraloy® iron alloy; Tank ring – silicon bronze • Globes – EVO – glass, heat strengthened plate glass; EVA: glass, heat- and impact-resistant Standard Finishes: EVA160 Ordering Information: Cat. # Watts Lamp (not furnished) Hub Size EVO2376 EVA160 75 100, A-21 75R 30/SP reflector spot (medium base) Medium base 1 Tank Ring Mounting EVA160 • Copper-free aluminum – epoxy powder coat • Feraloy iron alloy – cadmium electrogalvanized and aluminum acrylic paint • Silicon bronze – natural Size Ranges: • 1/2" and 3/4" hubs Capacity Ranges: • EVO – 75 watt, reflector spot max. • EVA – 100 watt, A-21 max. 1212 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business /2 & 3/4 /2 1 1212-1213.qxp 12/16/2013 7:11 PM Page 1213 Cl. I, Groups B, C, D Cl. I, Zone I, IIB+H2 Cl. II, Groups E, F, G Class III Simultaneous Presence EVTL Explosionproof Task Light Wet Locations Marine Locations NEMA 3, 3R, 4, 4X 10L Applications: EVTL Task Light Luminaires are used: • For various task lighting requirements in locations that are hazardous (classified) due to the presence of flammable gases or vapors, combustible dusts, or easily ignitible fibers and flyings • In marine applications where water spray and corrosive atmospheres are considerations • In areas where conventional lighting is not acceptable due to size and/or location • In locations where an adequate light source is necessary for tank, instrument, and gauge applications • In porthole or sightglass applications where a spotlight is required for visibility inside tanks, vats, and process vessels • In manufacturing plants, refineries, pharmaceutical, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, grain processing and handling facilities, and other heavy industrial applications Features and Benefits: EVTL1L50 Certifications and Compliances: Standard Materials: • NEC/CEC: Class I, Division 1 & 2, Groups B, C, D Class II, Group E, F, G Class III Class I, Zone 1 & 2, Group IIB + H2 Wet locations Marine locations NEMA 4X • NEC: Simultaneous Presence • UL Standards: 844—Hazardous (Divisions Classified) Locations 1571—Ordinary and Wet Locations, Marine Outside Type • CSA Standards: C22.2 No. 137 • Housing — copper-free aluminum • 3/4" NPT hub and plug — aluminum • Mounting bracket(s) and external hardware — stainless steel • Gasket — silicone rubber • Lens — heat- and impact-resistant clear glass Standard Finishes: • Aluminum housing (exterior) — Corro-free™ epoxy powder coat • Stainless steel — natural Ratings (Electrical/Size): Source/Wattage (Medium Base Lamps) • 50PAR20 type—50W 120V halogen parabolic reflector; lamp life 2000-2500 hrs. • 130V lamps available to extend lamp life to 5000+ hrs. Voltage • 120V 60 Hz Hub Size • (1) 1/ 2" NPT • For through-feed, use EVTL-TF1 Ordering Information: Cat. # Conduit Entry Mounting Style Wattage EVTL1B50 EVTL1L50 1 /2" 1 /2" Bracket (Universal) Leg (Site Glass) 50 50 Temperature Performance Data: Cat. # Maximum Ambient °C Class I, Div. 1, Groups B, C, D Class II, Div. 1, Groups E, F, G Class III Simultanenous Presence Class I, Zone 1, IIB + H EVTL1B50 EVTL1L50 40 40 T3B T3B Supply Wire °C 85 85 Install luminaire within aiming ranges shown on nameplate (see Dimensions). www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1213 10L • Class I, II, III, Simultaneous Presence suitable for most hazardous (classified) areas • Class I, Group B standard - suitable for areas containing hydrogen • Wet and marine (NEMA 4X) suitability perfect for hose down applications • 55° ambient suitability addresses higher ambients typical of industrial plants • Cast copper-free aluminum housing with Corro-free™ epoxy powder coat finish for superior corrosion resistance • Stainless steel mounting brackets and hardware for superior corrosion resistance • Two mounting styles (bracket and leg) to maximize mounting flexibility • Bracket (universal) for ceiling, wall, or base mounting • Leg (site glass) for site glass mounting • Uses standard 50 watt PAR 20 medium base 120V lamps - improved light output, economical, long life 2000-2500 hour light source • Uses 50PAR20 130V lamps for added lamp life - increase lamp life to 5000+ hours while maintaining 76% lumen output • 50PAR20 lamps available in both flood and spot light patterns - vary the illumination characteristics by simply changing lamps • Easy access interior reduces maintenance and lamp replacement time • Seal within 5 ft. (not 18") of luminaire provides greater flexibility in seal location EVTL1B50 1214-1215.qxp 12/16/2013 10L 7:12 PM Page 1214 EVTL Explosionproof Task Light Dimensions and Weights Aiming Range: Dimensions: 10L Bracket Mount Dimensions: Leg Mount Net Luminaire Weights: (lbs.) Luminaire Cat. # Weight (lbs.) EVTL1B50 EVTL1L50 EVTL-TF1 7 7 1 /2 1214 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1214-1215.qxp 12/16/2013 7:12 PM Page 1215 EVTL Explosionproof Task Light Photometric Data 10L Lamp Light Distribution – (Philips lamp data shown. Similar for other manufacturers.) Data shown is for 120 volt lamps. For 130 volt lamps adjust data using a .76 multiplier. 10L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1215 1216.qxp 12/16/2013 7:12 PM Page 1216 10L ELG Gauge Luminaires Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone 1 & 2, IIB Explosionproof Applications: ELG Gauge Lights are used: • In hazardous areas to illuminate liquid level gauges over entire length of gauge • Clamped to rear of liquid level gauge and conduit is attached to the ELG hubs; light is reflected by Lucite reflector along the entire length of the gauge; liquid level shows on front of gauge; all light is concentrated on liquid column – no spill light Features: • Even illumination over entire length of gauge • Variety of sizes to fit many gauges • Several lights can be used in tandem to illuminate long gauge Certifications and Compliances: • NEC/CEC: Class I, Division 1 and 2, Groups C, D ELG329 with LE49 reflector Standard Materials: • Body – copper-free aluminum • Reflectors – plexiglass Ordering Information: Standard Finishes: Description • Body – electrogalvanized and aluminum acrylic paint Gauge Light (less reflector) — ELG329 Size Ranges: Short – Style Reflector 41/2 51/2 LE34 LE35 Long – Style Reflector 13 15 17 193/4 22 251/4 263/4 LE46 LE47 LE48 LE49 LE410 LE412 LE413 • 1" conduit through-feed 10L Capacity Ranges: • 120V medium screw base "A19" style incandescent lamp 58W maximum • 25 watt – medium base – 1000 hour life • 52 watt – medium base – 2500 hour life • 58 watt – medium base – 3000 hour life Length (L) (inches) Cat. # Dimensions: Plexiglass Reflectors Short Style Long Style Temperature Performance Data: Based on 40°C ambient 58 Watt – T4A Maximum Options: Description Suffix Group B suitability ........................... GB Suggested Lamps: Lamps not furnished Manufacturer Cat. # 25 52 Watt Watt General Electric Osram/Sylvania Philips 25A 25A 25A 1216 60A/52WMP/98 60A/52/SS/XL 60A-52A/99/EW www.crouse-hinds.com US: 1-866-764-5454 58 Watt 58A19/62 Volts 120 120 120 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Modify Date : 2014:02:12 13:35:27-05:00 Create Date : 2014:02:10 15:38:46-05:00 Metadata Date : 2014:02:12 13:35:27-05:00 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Creator : mabe Document ID : uuid:9b2c706b-72da-4574-9a32-65adc77a63ee Instance ID : uuid:3e995305-2d3d-416f-9aa6-76a90cb488f7 Producer : Acrobat Distiller 9.0.0 (Windows) Page Count : 356 Author : mabe GTS PDFX Conformance : PDF/X-1a:2001 GTS PDFX Version : PDF/X-1:2001 Title : Trapped : FalseEXIF Metadata provided by EXIF.tools