Product Detail Manual

110295-Attachment 110295-Attachment 110295-Attachment 782274 Batch5 unilog cesco-content

2014-07-05

: Pdf 110295-Attachment 110295-Attachment 662276 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 356

DownloadProduct Detail Manual
Open PDF In BrowserView PDF
861.qxp

12/16/2013

6:37 PM

Page 861

Industrial Lighting
Section L
Advanced technology, expert support, global certifications, and an unmatched selection of
proven solutions combine to deliver superior illumination, increased safety, and the lowest
possible cost of ownership.

New Products in the Lighting Product Line

Section

•
•
•
•
•
•
•
•
•
•

2L
2L
2L
2L, 6L
2L
2L, 6L
2L, 6L
2L
2L
2L

Hazard•Gard EVLL Series Explosionproof LED Luminaires
Hazard•Gard® LPL Series Explosionproof LED Luminaires
LL48 Linear LED Luminaires
Champ® FMV LED Series Floodlight Fixtures
Champ® Pro PVM Series
Champ® Pro PFM Series
Champ® Pro PFM Series 25L and 50L LED Floodlights
Vaporgard™ Pro P2L Series
Industrial High Bay LED Series Luminaires
Endure™ LED Wall Pack
®

Notable changes to the Lighting section of this catalog
• Section 3L now contains both hazardous/non-hazardous HID luminaires and induction lighting (previously 3L & 5L)

862-863.qxp

12/16/2013

L

6:38 PM

Page 862

Industrial Lighting
Table of Contents

Section L of the Eaton's Crouse-Hinds
Catalog contains information on industrial
lighting.
Product details on individual luminaires are
given in ten separate sections, as noted
below.

Considerations for
Selection
Preceding the ten product sections is a
Selector Guide. Included in this section is
information on:
• A selection of the appropriate light
source for a given application
• A Quick Selector Guide of the luminaires
that are designed and approved to meet
the various environmental requirements
of the National Electric Code
• Determining the proper size (i.e.,
wattage) and number of units to achieve
the desired light levels in a given
application
• Methods to follow in making a luminaire
layout. Cat. Nos. are shown, in many
cases, for complete assemblies
including mounting, reflector, globe, and
guard, as well as individual components.
In these cases, ordering can be done by
component or by complete assembly.
Photometric and other technical data is
included in each section for the luminaires
it contains
Information relating to product families in
the Lighting Section is shown as follows:

Section 1L
L

Incandescent Lighting
(for use in hazardous [classified] and nonhazardous locations)
EVI Series Vaporgard™ Series
EV Series V Series
NDA Corro•Gard™ Series

Section 2L
LED Luminaires
(for use in hazardous [classified] locations,
non-hazardous locations, and marine
locations)
EV LED Series
Hazard•Gard® EVLL Series
Hazard•Gard LPL Series
LL48 Series
Champ® VMV LED Series
Champ® FMV LED Series
Vaporgard™ LED Series
N2LPS Light-Pak™ Series
Ex-Lite Series
CCH UX Series
Champ® Pro PVM Series
Champ® Pro PFM Series
Vaporgard™ Pro P2L Series
Industrial High Bay LED Series
Endure™ LED Series

862

www.crouse-hinds.com

US: 1-866-764-5454

Section 3L

Section 7L

High Intensity Discharge (H.I.D.)
Lighting — Enclosed and
Gasketed

Luminaire Hangers and
Accessories

(for use in hazardous [classified] locations,
non-hazardous locations, and marine
locations)
Indoor and outdoor vaportight luminaires
for use in applications where dirt,
moisture, and corrosion problems exist.
Included are units with integral ballasts.
Champ® VMV Series
Champ® LMV Series
Champ® DMV Series
VMVIG/DMVIG Series
Champ® N2MV Series
Champ® NVMV Series

Section 4L
High Intensity Discharge (H.I.D.)
Lighting
(for use in hazardous [classified] locations)
Indoor and outdoor luminaires and
accessories. Included are luminaires with
integral ballasts.
Hazard•Gard® EVLS
Hazard•Gard® EVLP
Hazard•Gard® EVM

Section 8L
Portable Lighting
A variety of portable luminaires for
hazardous and non-hazardous
applications.
VS
EVH
RCDER
EVP

Section 9L

Section 5L
Fluorescent Lighting
(for use in hazardous [classified] locations
and non-hazardous locations)
Indoor and outdoor fluorescent luminaires
and accessories for application in all
classes of hazardous and non-hazardous
locations.
For hazardous
For non-hazardous
locations
locations
CPMVF
NFL
EVF, EVFDR
VF Vaporgard Series
FVN, FVS
EVFT, DMVF
N2MVF, EVLPF
VF, eLLK, nLLK
eLLB20

Section 6L
Floodlights
(for use in hazardous [classified] locations
and non-hazardous locations)
Champ® FMV Series
CPMV Champ-Pak™ Wall Pack
EVMA-S812 Hazard•Gard® Series
F2MV, FMV1000
FZD
RCDE
SSFMV Voyager nR™

CAN: 1-800-265-0502

(for use in hazardous [classified] locations
and non-hazardous locations)
A variety of luminaire hangers for use with
the luminaires listed. Information on
mounting accessories required and typical
luminaire weights also included.
For hazardous
For non-hazardous
locations
locations
EAHC, EFHC
AL
EC
AHG
EFH
ARB
GUA, GUF
FHM
UNR
UNE, UNH, UNHC
CPS
UNJ
UNJC

Emergency Lighting
(for use in hazardous [classified] locations)
Emergency lighting for use in power
outage situations. Also, exit signs and
strobe warning lights.
N2LPS Light-Pak™ Series
CPMVFB
EXL Exit Sign
DMVFB
™
ELPS Light-Pak Series
N2MVFB
Ex-Lite
EVLPFB
CCH UX Series

Section 10L
Specialty Lighting
Luminaires for use in applications where
conventional lighting is not acceptable
due to size and/or location, such as tank,
instrument, and gauge applications.
For hazardous
For non-hazardous
locations
locations
EV – tank lights
V Observation
EVTL
ELG – gauge light

Copyright© 2013 Eaton’s Crouse-Hinds Business

862-863.qxp

12/16/2013

6:38 PM

Page 863

L

Industrial Lighting Products
Quick Reference Chart

Application
Environment

Light Source
LED

Incandescent

H.I.D. / Induction
• Pulse Start
Metal Halide
• Metal Halide
• High Pressure
Sodium

Fluorescent
• Linear
• Long Twin
Tube
• Compact

Emergency
& Warning
• Exit Signs
• Emergency
Lighting

WallPacks &
Floodlights
• Pulse Start
Metal Halide
• Metal Halide
• High Pressure
Sodium
• Incandescent

Section 2L
Champ® Pro PVM
Series,
Champ® Pro PFM
Series,
Vaporgard™ Pro
P2L Series,
Industrial High
Bay

Section 1L
Vaporgard™, V
Series, NDA
Section 11L
V160 Tank light

Section 3L
LMV, DMV, VMV,
N2MV Champ®,
Champ Induction

Section 5L
VF Series, NFL,
FVN, FVS,
DMVF, N2MVF

Section 2L
Ex-Lite, CCH UX,
N2LPS LightPak™
Section 9L
DMVFB, N2MVFB

Section 6L
F2MV, FMV,
FMV1000

Marine/Wet
Locations or 4X

Section 2L
Champ® VMV
LED,
Vaporgard™ LED,
EV LED

Section 1L
NDA

Section 3L
LMV, DMV, VMV,
N2MV Champ®
Section 4L
EVLP, EVM
Hazard•Gard®

Section 5L
NFL, FVS, DMVF,
N2MVF, CPMVF,
EVFDR,
EVFT
Illuminator™

Section 2L
Ex-Lite, CCH UX
Section 9L
DMVFB

Section 6L
CPMV, F2MV,
FMV, FMV1000

Corrosive

Section 2L
Champ® VMV
LED,
Vaporgard™ LED,
EV LED

Section 1L
Vaporgard™,
NDA

Section 3L
LMV, DMV, VMV,
N2MV Champ®,
Champ Induction

Section 5L
NFL, N2MVF,
FVS,
VF Series, DMVF,
CPMVF

Section 2L
Ex-Lite, CCH UX,
N2LPS LightPak™
Section 9L
DMVF-EXD Exit,
N2MVFB, DMVFB

Section 6L
CPMV, F2MV,
FMV, FMV1000

Class I, Div. 1 or
Zone 1

Section 2L
EV LED,
EVLL,
LPL

Section 1L
EV
Section 10L
EVTL, EVA160,
EVO, ELG

Section 4L
EVLP, EVLS,
EVM
Hazard•Gard®

Section 5L
EVF, EVFDR,
EVFT
Illuminator™,
EVLPF, eLLK

Section 9L
EXL Exit,
EVLPF-EXD Exit,
ELPS Light-Pak™,
EVLPFB

Section 6L
FZD, EVM-S812,
RCDE

Class I, Div. 2
and Zone 2

Section 2L
Champ® VMV
LED,
Vaporgard™ LED,
Champ® FMV
LED,
LL48

Section 1L
Vaporgard™,
NDA

Section 3L
LMV, DMV, VMV,
N2MV Champ®,
Champ Induction

Section 5L
VF Series, NFL,
nLLK, eLLK, FVN,
FVS, CPMVF,
DMVF, N2MVF

Section 2L
Ex-Lite
Section 9L
DMVF-EXD Exit,
N2LPS LightPak™,
DMVFB, N2MVFB

Section 6L
CPMV, F2MV,
FMV, FMV1000,
FZD

Restricted
Breathing
• Class I, Div 2
and Zone 2
• Certified IEC
Zone 2

Section 2L
Champ® VMV
LED,
Champ® NFMV
LED,
Vaporgard™
NV2L LED

Section 3L
LMV, DMV, VMV,
N2MV Champ®,
Champ Induction

Section 5L
CPMVF, DMVF,
N2MVF

Section 9L
DMVFB, N2MVFB

Section 6L
CPMV, F2MV,
FMV

Class II
Class III
Simultaneous
Presence

Section 2L
Champ® VMV
LED,
EV LED,
Vaporgard™ LED,
Champ® FMV
LED,
EVLL

Section 3L
LMV, DMV, VMV,
N2MV Champ®,
Champ Induction
Section 4L
EVLP, EVM
Hazard•Gard®

Section 5L
FVN, nLLK, eLLK,
FVS, DMVF,
N2MVF,
EVF, EVFDR,
EVFT, EVLP

Section 2L
Ex-Lite
Section 9L
EXL,
N2LPS LightPak™,
DMVFB,
N2MVFB,
ELPS Light-Pak™

Section 6L
CPMV

Section 8L
EVP

Section 5L
EVF, EVFT

Section 8L
EVP

Section 8L
EVH

Section 1L
EV
Section 10L
EVTL, EVO

Paint Spray
Portables

Section 8L
VS, EVH,
RCDER

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

L

General
Industrial

Copyright© 2013 Eaton’s Crouse-Hinds Business

863

864-865.qxp

L

12/16/2013

6:38 PM

Page 864

Industrial Lighting Products
Lighting Layout Services

Lighting Application and Design
In the past, engineers had to calculate lighting layouts and design using complex mathematical formulas - also known as the "Lumen
Method" and "Point-By-Point" Method. Today, there are software programs that can easily run these calculations very quickly.
Lighting layouts, analysis, and design from Eaton's Crouse-Hinds deliver a real competitive advantage. For over 100 years, Eaton's CrouseHinds has been providing hazardous area lighting solutions. Our light fittings are manufactured to the highest standards and will provide
years of reliable service and performance under the harshest conditions.

Lighting Software
Eaton's Crouse-Hinds' Luxicon Pro™ software program makes it very easy to perform lighting calculations and create professional quality
designs. Our latest version, LUXICON® 2.5.25, is distributed free of charge and includes a tutorial to introduce users to its operation and
several "Wizards" that will assist in a step-by-step process to create your own lighting design. You can also add in objects that will account
for light inference caused by equipment, walls, and other obstructions in the work area. It will also provide detail point-by-point calculations
and statistical analysis.

Pro

TM

Point-by-point light calculation in plan view

Lighting Layout Services
L

Need help with a more complex lighting design or analysis?
Then take advantage of our free lighting design service. Our lighting designers can provide you with lighting layouts for more complex
projects that will interface with the latest version of AutoCAD drawings and will provide a more detailed lighting analysis.

Calculations shown with light fixture placement

864

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Illuminance rendering

Copyright© 2013 Eaton’s Crouse-Hinds Business

864-865.qxp

12/16/2013

6:38 PM

Page 865

Industrial Lighting Products

L

Mercury Vapor Luminaires Discontinuation Notice
Eaton's Crouse-Hinds no longer produces
luminaires containing Mercury Vapor ballasts in any
of our U.S. facilities.

Alternative Solutions

In 2005, the U.S. government signed the Energy Policy Act of 2005.
The law, commonly referred to as EPACT 2005, contained many new
changes in requirements for energy production, energy
transportation, and energy efficiency. One of those changes calls for
the elimination of manufacturing and importation of Mercury Vapor
(MV) ballasts in the United States after January 1, 2008.

LED

Mercury Vapor ballasts have lower lumens per watt than alternative
HID light sources and are far less energy-efficient than LED, High
Pressure Sodium (HPS), or Metal Halide (MH) ballasts. As demand
for energy-efficient lighting grows, we expect a subsequent drop in
the usage of Mercury Vapor ballasts globally. This could lead to
longer lead times and potentially worldwide discontinuation at some
point in the future.
Eaton's Crouse-Hinds suggests the use of alternative
technologies, such as LED, that provide better efficacy, color
rendering, length of life, and environmentally friendlier solutions.
Alternative HID light sources, such as High Pressure Sodium or Metal
Halide, are also viable product solutions.
While we recommend switching to an alternative light source, there
are many countries in the world that still allow the use of Mercury
Vapor ballasts. As long as the ballasts and lamps remain available,
we can still offer Mercury Vapor luminaires out of our manufacturing
facilities located outside of the United States. The Mercury Vapor
luminaires will be manufactured in our Eaton's Crouse-Hinds Mexico
facility and shipped directly from there.
For available Mercury Vapor products, please contact customer
service.

US: 1-866-764-5454

Lumens

Lumens
per Watt

60,000
60,000
60,000
60,000
60,000

3,515
5,288
7,404
9,515
10,935

77.39
78.93
78.77
83.47
92.67

60,000
60,000
60,000
60,000
60,000

4,386
6,720
8,478
10,420
12,940

68.53
75.51
70.07
69.93
72.29

60,000

1,633

74.23

60,000
60,000

1,670
2,248

55.67
62.44

60,000
60,000
60,000
60,000
60,000

5,625
6,750
9,000
10,500
13,500

70.30
67.50
69.23
69.54
77.14

High Pressure Sodium
100W
24,000
250W
24,000
400W
24,000
1000W
24,000

9,500
28,500
50,000
140,000

95.00
114.00
125.00
140.00

Metal Halide
175W
250W
400W
1000W

10,000
20,000
20,000
12,000

13,500
20,500
36,000
110,000

77.00
82.00
90.00
110.00

Pulse Start Metal Halide
175W
15,000
250W
15,000
400W
20,000

16,000
23,800
44,000

91.00
95.00
100.00

Induction
55W
85W
165W

100,000
100,000
100,000

3,500
6,000
12,000

63.00
70.00
72.00

Mercury Vapor
100W
175W
250W
400W
1000W

24,000
24,000
24,000
24,000
24,000

4,100
7,900
12,100
21,000
57,500

34.00
45.00
48.00
52.00
57.00

VMV / PVM
41W
67W
94W
114W
118W
FMV / PFM
64W
89W
121W
149W
179W
V2L / P2L
22W
EV LED
30W
36W
EVLL
80W
100W
130W
151W
175W

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

L

www.crouse-hinds.com

Hours

Luminaire Type

865

866-867.qxp

12/16/2013

L

6:38 PM

Page 866

Lamps Used With
Eaton's Crouse-Hinds
Luminaires

Lamp
Watts

H.I.D. Medium Base
Series – LMV, EVLP_ 1

ANSI
Ballast

Manufacturer
Lamp Catalog Number
GE

Osram/Sylvania

Phillips

Venture

High Pressure Sodium
50
70
100

S68
S62
S54

LU50/MED
LU70/MED
LU100/MED

LU50/MED
LU70/MED
LU100/MED

C50S68/M
C70S62/M
C100S54/M

150

S55

LU150/MED

LU150/MED

C150S55/M

70
100

M98
M90

MXR70/U/MED
MXR100/U/MED

MP70/U/MED
MP100/U/MED

MHC70/U/M/3K
MHC100/U/M/3K

175*

M57

MVR175/U/MED

M175/U/MED

MH175/U/M

MXR150/U/MED
MXR175/VBU/MED/PA

MP150/U/MED

Metal Halide
MH70W/U
MH100W/U

Pulse Start Metal Halide
150
175

M102
M137

L

*For export only.

866

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

MH150W/U/PS
MS175W/BU/MED/PS

866-867.qxp

12/16/2013

6:38 PM

Page 867

Lamps Used With
Eaton's Crouse-Hinds
Luminaires
Lamp
Watts

L

H.I.D. Medium Base
Series – LMV, EVLP_ 1

ANSI
Ballast

Manufacturer

Manufacturer

Lumens/Life (hrs)

Bulb

GE

O/S

PH

Venture

GE

O/S

PH

Venture

High Pressure Sodium
50
70
100

S68
S62
S54

4000/24K
6400/24K
9500/24K

4000/24K
6300/24K
9500/24K

4000/24K
6300/24K
9500/24K

B17
B17
B17

E17
E17
E17

ED17
ED17
ED17

150

S55

16000/24K

15800/24K

16000/24K

B17

E17

ED17

70
100

M98
M90

5500/12K
9000/15K

5200/15K
8500/15K

6200/10K
9300/12.5K

BD17
BD17

E17
E17

ED17
ED17

175*

M57

13600/10K

14400/10K

13500/10K

BD17

ED17

ED17

12500/15K
17700/15K

13300/15K

BD17
BD17

E17
E17

Metal Halide
5600/15K
9000/15K

ED17
ED17

Pulse Start Metal Halide
150
175

M102
M137

14000/15K
17500/15K

ED17
ED17

*For export only.

L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

867

868-869.qxp

12/16/2013

L

6:39 PM

Page 868

H.I.D. Mogul Base
Series - DMV, VMV, CPMV,
FMV, F2MV, EVLP_0, FZD

Lamps Used With
Eaton's Crouse-Hinds
Luminaires
Lamp
Watts

ANSI
Ballast

Manufacturer
GE

Osram/Sylvania

Phillips

Venture

High Pressure Sodium
50
70
100
150

S68
S62
S54
S55

LU50
LU70
LU100
LU150/55

LU50
LU70
LU100
LU150/55

C50S68
C70S62
C100S54
C150S55

150 (100V)
200
250
310
400
1000

S56
S66
S50
S67
S51
S52

LU150/100
LU200
LU250
LU310
LU400
LU1000

LU150/100
LU200
LU250
LU310
LU400
LU1000

C150S56
C200S66
C250S50
C310S67
C400S51
C1000S52

M175/U
M250U
M400/U
M400/U/BT-28
M1000/U
M1500/BD

MHC100/U/ED28/HR/4K
MH175/U
MH250/U
MH400/U
MH400/U/ED28
MH1000/U
MH1500/BD

(Base up +/– 15%)

(Base up +/– 15%)

Metal Halide
70
100
175*
250*
400*
400*
1000
1500

M98
M90
M57
M58
M59
M59
M47
M48

MVR175/U
MVR250/U
MVR400/U
MVR400/U/ED28
MVR1000/U
MVR1500/HBD

Pulse Start Metal Halide

L

150
175
200
250

M102
M137
M136
M138
M138
M132
M131
M131
M135
M135
M135
M135
M141

320
350
400

1000

MXR175/VBU/PA

CDM150/U/PS/4K ALTO
MS175/BU/PS

MXR250/VBU/PA

MS250/BU/PS

MXR320/VBU/PA

MS320/PS/BU-ONLY

MS320W/BU/PS

MXR400/VBU/PA

MS400/PS/BU-ONLY

MS400/BU/PS

HQI-DE 70/WDX

CDM70/TD/830

HID Double Contact Metal Halide for EVP Series
70W

CMH70/TD/830/R7S

*For export only.

868

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

MH70W/U/ED28
MH100W/U/ED28

MH150W/U/ED28/PS
MS175W/BU/PS
MH200W/U/PS
MH250W/HBU/PS
MH250W/HBD/PS
MH320W/U/ED28/PS
MH350W/U/PS
MH350W/U/ED28/PS
MH400W/HBU/PS
MH400W/HBD/PS
MH400W/HBU/ED28/PS
MH400W/HBD/ED28/PS

868-869.qxp

12/16/2013

6:39 PM

Page 869

Lamps Used With
Eaton's Crouse-Hinds
Luminaires
Lamp
Watts

ANSI
Ballast

L

H.I.D. Mogul Base
Series - DMV, VMV, CPMV,
FMV, F2MV, EVM, EVLP_0, FZD

Manufacturer

Manufacturer

Lumens/Life (hrs)

Bulb

GE

O/S

PH

Venture

4000/24K
6400/24K
9500/24K
16000/24K
15000/24K
22000/24K
28000/24K
37000/24K
51000/24K
140000/24K

4000/24K
6300/24K
9500/24K
16000/24K
15700/24K
22000/24K
29000/24K
37000/24K
50000/24K
130000/24K

4000/24K
6300/24K
9500/24K
16000/24K
16000/24K
22000/24K
28500/24K
37000/24K
50000/24K
140000/24K

GE

O/S

PH

ED23 1/2
ED23 1/2
ED23 1/2
ED23 1/2
ED28
ED18
ED18
ED18
ED18
E25

ET23 1/2
ET23 1/2
ET23 1/2
ET23 1/2
BT28
ET18
ET18
ET18
ET18
E25

ED23 1/2
ED23 1/2
ED23 1/2
ED23 1/2
ED28
ED18
ED18
ED18
ED18
E25

Venture

High Pressure Sodium
50
70
100
150
150 (100V)
200
250
310
400
1000

S68
S62
S54
S55
S56
S66
S50
S67
S51
S52

Metal Halide
70
100
175
250
400
400
1000
1500

M98
M90
M57
M58
M59
M59
M47
M48

5600/15K
9000/15K
13600/10K
20800/10K
36000/20K
36000/20K
105000/12K
155000/3K

14400/10K
22000/10K
36000/20K
36000/20K
110000/15K
155000/3K

13500/10K
20500/20K
36000/20K
36000/20K
110000/12K
165000/3K

ED28
ED28
ED28
ED28
ED37
ED28
BT56
BT56

BT28
BT28
BT37
BT28
BT56
BT56

ED28
ED28
ED37
ED28
BT56
BT56

Pulse Start Metal Halide
150
175
200
250
320
350

1000

17200/15K

13000/24K
16000/15K

23000/15K

23800/15K

31000/15K

32000/20K

44000/20K

41000/20K

44000/20K

14000/15K
17500/15K
21000/15K
25000/15K
25000/15K
33000/20K
37000/20K
37000/20K
44000/20K
44000/20K

ED23 1/2

ED23 1/2
ED28

ED28

ED28

ED28

BT28

ED28

ED37

BT37

ED37

44000/20K

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

ED28
ED28
ED28
ED28
ED28
ED28
ED37
ED28
ED37
ED37
ED28
ED28

L

400

M102
M137
M136
M138
M138
M132
M131
M131
M135
M135
M135
M135
M141

869

870-871.qxp

12/16/2013

6:39 PM

Page 870

Lamps Used With
Eaton's Crouse-Hinds
Luminaires

L

Lamp
Watts

Fluorescent Lamps

Luminaire
Series

Base

Manufacturer
GE

Osram/Sylvania

Phillips

Compact
5W-T4

G23

VF

F5BX/SPX41/840

CF5DS/841

PL-S5W/27

7W-T4

G23

VF

F7BX/SPX35/835

CF7DS/835

PL-S7W/35

9W-T4

G23

VF

F9BX/SPX35/835

CF9DS/835

PL-S9W/35

13W-T4

GX23-2

DMVF (Discontinued)

F13DBX23T4/SPX35

CF13DD/835

PL-C13W/35/USA

26W-T4

GX24q-3

DMVF, N2MVF,
CPMVF, EVLPF

F26TBX/SPX35/A/4P

CF26DT/E/IN/835

PL-T26W/35/4P/ALTO

32W-T4

GX24q-3

DMVF, N2MVF,
CPMVF, EVLPF

F32TBX/SPX35/A/4P

CF32DT/E/IN/835

PL-T32W/35/4P/ALTO

42W-T4

GX24q-4

DMVF, N2MVF,
CPMVF, EVLPF

F42QBX/SPX35/A/4P

CF42DT/E/IN/835

PL-T42W/35/4P/ALTO

Long Twin Tube
39

2G11

EVFT

F39/36/BX/SPX35

FT36DL/835

PL-L36W/35

40

2G11

NFL, FVS

F40/30BX/SPX35

FT40DL/835/RS

PL-L40W/35/RS

32W-T8

Medium
Bipin

NFL, FVN, EVF,
EVFDR

F32T8/SP35

F032/735

F32T8/TL735/ALTO

40 (34) W-T12

Medium
Bipin

NFL, FVN, EVF,
EVFDR

F40CW/RS/WM

F40CW/SS

F40CW/RS/EW/ALTO

54W-T5HO

Miniature
Bipin

FVN

F54T5/841/WH/ECO

HO54W/835

F54T5/830/HO/ALTO

60W (800ma)-T12
High Output

Recessed
Double Contact

FVN, EVF,
EVFDR

F48T12/CW/HO

F48T12/CW/HO

F48T12/CW/HO

110W (1500ma)-T12
Very High Output

Recessed
Double Contact

EVF, EVFDR

F48T12/CW/1500

F48T12/CW/VHO

F48T12/CW/VHO

L

Linear

870

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

870-871.qxp

12/16/2013

6:39 PM

Page 871

Lamp
Watts

L

Incandescent & Quartz
(Halogen) Lamps

Lamps Used With
Eaton's Crouse-Hinds
Luminaires
Base

Luminaire
Series

Manufacturer
Lumens/Life (Hrs)
GE

Osram/Sylvania

Phillips

Compact
5W-T4

G23

VF

250/10K

230/10K

250/10K

7W-T4

G23

VF

400/10K

400/10K

400/10K

9W-T4

G23

VF

600/10K

580/10K

600/10K

13W-T4

GX23-2

DMVF (Discontinued)

810/10K

780/10K

860/10K

26W-T4

GX24q-3

DMVF, N2MVF,
CPMVF, EVLPF

1800/10K

1800/10K

1800/10K

32W-T4

GX24q-3

DMVF, N2MVF,
CPMVF, EVLPF

2200/10K

2400/10K

2400/10K

42W-T4

GX24q-4

DMVF, N2MVF,
CPMVF, EVLPF

3200/10K

3200/10K

3200/10K

Long Twin Tube
39

2G11

EVFT

2850/12K

2900/12K

2900/12K

40

2G11

NFL, FVS

3150/20K

3150/20K

3150/20K

32W-T8

Medium
Bipin

NFL, FVN, EVF,
EVFDR

2850/20K

2800/20K

2850/20K

40 (34) W-T12

Medium
Bipin

NFL, FVN, EVF,
EVFDR

2650/20K

2700/20K

2650/20K

54W-T5HO

Miniature
Bipin

FVN

4600/30K

4450/24K

4750/35K

60W (800ma)-T12
High Output

Recessed
Double Contact

FVN, EVF,
EVFDR

4050/12K

4050/12K

4050/12K

110W (1500ma)-T12
Very High Output

Recessed
Double Contact

EVF, EVFDR

6200/10K

6600/10K

7050/12K

Linear

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

871

L

www.crouse-hinds.com

872-873.qxp

12/16/2013

6:40 PM

Page 872

Lamps Used With
Eaton's Crouse-Hinds
Luminaires

L

Max Watts And
Bulb Type

Incandescent & Quartz
(Halogen) Lamps

Luminaire
Series

Manufacturer
GE

Phillips

EXLD

25T10

25T10

25T10

50W PAR20

EVTL

50PAR20/H/SP10
50PAR20/H/FL25

50PAR20/CAP/NSP
50PAR20/CAP/NFL

50PAR20/HAL/NSP9
50PAR20/HAL/NFL30

52W A19
58W A19

ELG
ELG

60A52WMP/98

60A52/SS/XL
58A19/62

60A-52A/99/EW

25W T10

60W T10

EXL

60T10

60T10

60T10

65W BR30

EVO2376

75R30/SP/65WM

65BR30/SP

65BR30/SP20

75W ER30

EVO2376

75ER30

75ER30

75ER30

100W A19

EV 40 Series / EVI

100A (IF)

100A (IF)

100A (IF)

100W A21

V160, EV160, EVH,
EV 15 Series / EVI

100A21 (IF)

100A21 (IF)

100A21 (IF)

100W A23

VS

100A23 120V

100A23

100A23

100W D.C. Bay

Suffix QTZ

Q100CL/DC

100Q/CL/DC

100Q/CL/DC

150W A21

Vaporgard 150W
EV 10 Series / EVI
EV 20 Series

150A (IF)

150A (IF)

150A (IF)

150W A23

V Series

150A23 (IF)

150A23/CL

150W PAR38

RCDE6

150PAR/FL

150PAR38/2FL

200W A23

Vaporgard 200W
EV 10 Series / EVI

200A23 (IF)

200A (IF)

200W A25

Vaporgard 200W
EV 15 Series / EVI

200W PS25

EV 15 Series / EVI

200W PS30

EV 20 Series / EVI
EV 30 Series / EVI

200 130V

300W PS25

Vaporgard 300W
NDA
EV 15 Series / EVI

300M

300W PS30

Vaporgard 300W
EV 20 Series / EVI
EV 15 Series / EVI

300M/99 (130v)

300M/CL

300M/PS30

300W R40

RCDE6

300R/FL

300R40/FL

300BR/FL

300W PS35

EV 30 Series / EVI

300

300/CL

500W PS40

EV 30 Series / EVI

500PS40

500W PAR64

RCDE10

500PAR64/MFL

L
872

Osram/Sylvania

www.crouse-hinds.com

US: 1-866-764-5454

200A25/35
200PS25/99XL

CAN: 1-800-265-0502

200PS/CL 130V

200 130V
300M

300
500PS40

500PAR64/MFL

Copyright© 2013 Eaton’s Crouse-Hinds Business

500PAR64/MFL

872-873.qxp

12/16/2013

6:40 PM

Page 873

Incandescent & Quartz
(Halogen) Lamps

Lamps Used With
Eaton's Crouse-Hinds
Luminaires
Max Watts And
Bulb Type

Manufacturer

Manufacturer
Lumens
GE

O/S

L

Life-Hours
PH

GE

O/S

PH

25W T10

248

232

260

1000

1000

1000

50W PAR20

570
570

530
530

550
550

2500
2500

2500
2500

2000
2000

52W A19

670

650

564

2500

2500

4250

58W A19

630

630

630

3000

3000

3000

60W T10

740

630

745

1000

1000

1000

65W BR30

775

640

2000

2000

2000

75W ER30

850

750

2000

2000

2000

100W A19

1710

1750

1650

750

750

750

100W A21

1710

1690

1680

750

750

750

100W A23

1600

1730

750

750

750

100W D.C. Bay

1600

1600

1600

2000

2000

2000

150W A21

2850

2780

2850

750

750

750

2810

2475

750

1275

1660

1660

2000

2000

3930

3800

150W A23
150W PAR38

1660

200W A23

2000

750

750

200W A25

2720

2720

2720

3500

3500

3500

200W PS25

3000

3000

3000

2500

2500

2500

200W PS30

2725

2665

2825

1950

1875

2120

300W PS25

6200

6280

750

750

750

300W PS30

3935

5870

6100

6800

7500

7500

3700

3030

np

2000

2000

2000

5820

5700

5700

1000

1000

1000

500W PS40

9900

10100

10100

1000

1000

1000

500W PAR64

6500

2000

2000

2000

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

L

300W R40
300W PS35

873

874-875.qxp

12/16/2013

Page 874

Ballasts Used With
Eaton's Crouse-Hinds
Luminaires

L

Watts

6:40 PM

ANSI
Code

Volts

Starting
Current

Operating
Current

Input
Watts

Kit Cat. #

t220/240–50 Hz

R-HPF
HX-HPF
HX-HPF

1.0
0.7/0.3
0.3/0.3

0.6
0.6/0.3
0.6/0.6

62
66
66

CHRBS050/120
CHRBS050/DT
CHRBS050/220 50

S62

120
120/208/240/277
120/277/347
220
480
220/240–50 Hz

R-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

0.9
0.8/0.5/0.4/0.4
.8/.4/.3
0.4
0.2
.5/.4

0.8
0.8/0.5/0.4/0.4
0.8/0.4/0.3
0.4
0.2
.5/.4

86
91
93
91
93
94

CHRBS070/120
CHRBS070/MT
CHRBS070/MT
CHRBS070/220
CHRBS070/480
CHRBS070/220 50

S54

120
120/208/240/277
120/277/347
220
480
220/240–50 Hz

R-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

1.5
1.3/0.8/0.7/0.6
1.3/0.6/0.5
0.7
0.4
0.5/0.5

1.1
1.2/0.7/0.6/0.5
1.2/0.5/0.4
0.6
0.3
0.7/0.6

115
130
130
130
130
130

CHRBS100/120
CHRBS100/MT
CHRBS100/TT
CHRBS100/220
CHRBS100/480
CHRBS100/220 50

150
(55v)

S55

120
120/208/240/277
120/277/347
220
480
220/240–50 Hz

R-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

2.3
2.0/1.2/1.0/0.9
2.0/0.9/0.5
1.1
0.5
0.9/0.8

1.5
1.7/1.0/0.8/0.7
1.7/0.7/0.6
0.9
0.4
0.9/0.8

170
188
188
188
188
188

CHRBS150/120
CHRBS150/MT
CHRBS150/TT
CHRBS150/220
CHRBS150/480
CHRBS150/220 50

150
(100v)

S56

120/208/240/277
480
220/240–50 Hz

CWA
CWA
R-HPF

1.2/0.7/0.6/.05
0.3
0.9/1.0

1.8/1.0/0.9/0.8
0.4
0.9/0.8

188
188
175

CHRBS150/MT CE
CHRBS150/480 CE
CHRBS150/220 50 CE

200

S66

120/208/240/277
480

CWA
CWA

1.4/0.8/0.7/0.6
0.4

2.4/1.4/1.2/1.0
0.6

250
250

CHRBS200/MT
CHRBS/200/480

S50

120
120/208/240/277
120/277/347
220
480
230–50 Hz

CWA
CWA
CWA
CWA
CWA
CWA

1.7
1.7/1.0/0.8/0.7
1.7/0.7/0.6
0.9
0.4
1.0

2.5
2.5/1.5/1.3/1.1
2.7/1.2/0.9
1.5
0.7
1.4

295
295
295
295
310
300

CHRBS250/120
CHRBS250/MT
CHRBS250/TT
CHRBS250/220
CHRBS250/480
CHRBS250/220 50

S51

120
120/208/240/277
120/277/347
220
480
230–50 Hz

CWA
CWA
CWA
CWA
CWA
CWA

3.3
3.3/1.8/1.5/1.4
3.3/1.4/1.0
1.6
0.8
1.9

3.8
3.8/2.2/1.9/1.7
3.8/1.7/1.3
2.1
1.0
2.0

457
464
464
457
464
465

CHRBS400/120
CHRBS400/MT
CHRBS400/TT
CHRBS400/220
CHRBS400/480
CHRBS400/220 50

S52

120/208/240/277
120/277/347
220
480
220/240–50 Hz

CWA
CWA
CWA
CWA
CWA

6.4/3.8/3.2/2.8
6.4/2.8/2.2
3.6
1.6
6.0/5.6

9.5/5.5/4.8/4.2
9.5/4.2/3.3
5.0
2.3
5.2/4.8

1100
1100
1100
1100
1100

CHRBS1000/MT
CHRBS1000/TT
CHRBS1000/220
CHRBS1000/480
CHRBS1000/220 50

50

70

L

100

S68

120
120 / 277

Type
R/HX/CWA

High Pressure Sodium
Data

250

400

1000

874

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

874-875.qxp

12/16/2013

6:40 PM

Page 875

Pulse Start Metal Halide
Data

Ballasts Used With
Eaton's Crouse-Hinds
Luminaires

Watts

ANSI
Code

150

L

Volts

Type
R/HX/CWA

Starting
Current

Operating
Current

Input
Watts

Kit Cat. #

M102

120/208/240/277
120/277/347/480

HX-HPF
HX-HPF

1.8/1.3/0.9/0.8
1.8/0.8/0.7

1.6/1.0/0.8/0.7
1.6/0.7/0.6

185
185

CHRBM150/MTS828
CHRBM150/TTS828

175*

M137

120/208/240/277
120/208/240/277
120/277/347/480

Super CWA
Super CWA
Super CWA

1.0/0.6/0.5/0.4
1.0/0.6/0.5/0.4
0.8/0.4/0.3

1.8/1.1/0.9/0.8
1.8/1.1/0.9/0.8
1.9/0.8/0.7

208
208
208

CHRBM175/MTS828
CHRBMVMV175/MTS828**
CHRBM175/TTS828

200*

M136

120/208/240/277
120/277/347
480

Super CWA
Super CWA
Super CWA

0.8/0.4/0.4/0.3
0.7/0.3/0.3
0.2

2.0/1.2/1.0/0.9
2.1/0.9/0.7
0.5

232
232
232

CHRBM200/MTS828
CHRBM200/TTS828
CHRBM200/480S828

250*

M138

120/208/240/277
120/277/347

Super CWA
Super CWA

2.3/1.3/1.2/1.0
2.0/0.9/0.8

2.5/1.5/1.3/1.1
2.5/1.1/0.9

288
290

CHRBM250/MTS828
CHRBM250/TTS828

M132

120/208/240/277
120/277/347
220

Super CWA
Super CWA
Super CWA

1.8/1.1/0.9/0.8
2.2/1.0/0.7
1.4

3.3/1.9/1.7/1.4
3.3/1.4/1.1
1.7

368
368
365

CHRBM250/MTS828
CHRBM250/TTS828
CHRBM250/220S828

480
230 / 50

Super CWA
Super CWA

0.5
1.1

0.8
1.6

368
365

CHRBM250/480S828
CHRBM250/220 50S828

320*

400*

1000

M135

120/208/240/277
120/277/347
480
230 / 50

Super
Super
Super
Super

CWA
CWA
CWA
CWA

2.9/1.7/1.5/1.3
3.2/1.4/1.1
0.8
2.0

3.8/2.2/1.9/1.7
3.8/1.7/1.4
1.0
2.1

452
450
452
454

CHRBM400/MT S828
CHRBM400/TTS828
CHRBM400/480S828
CHRBM400/220 50S828

M141

120/208/240/277
347
480
220/240–50 Hz

Super CWA
Super CWA
Super CWA
CWA

7.8/4.0/3.7/3.2
2.3
1.7
4.5/4.1

9.0/5.2/4.5/3.9
3.2
2.4
5.0/4.5

1080
1075
1075
1090

CHRBM1000/MTS828
CHRBM1000/347S828
CHRBM1000/480S828
CHRBM1000/220 50S828

L

*EISA compliant.
**For VMV replacement only.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

875

876-877.qxp

12/16/2013

6:40 PM

Page 876

Metal Halide
Data

Ballasts Used With
Eaton's Crouse-Hinds
Luminaires

L

Watts

ANSI
Code

Volts

Type
R/HX/CWA

Starting
Current

Operating
Current

Input
Watts

Kit Cat. #

70

M98

120/208/240/277
120/277/347
220
220/240–50 Hz

HX-HPF
HX-HPE
HX-HPF
HX-HPF

0.6/0.3/0.3/0.3
0.6/0.2/0.2
0.4
0.7/0.6

0.8/0.5/0.4/0.4
0.8/0.4/0.3
0.5
0.5/0.4

88
88
94
95

CHRBM070/MT
CHRBM070/TT
CHRBM070/220
CHRBM070/220 50

M90

120/208/240/277
120/277/347
220
480
220/240–50 Hz

HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

1.2/0.8/0.7/0.6
1.2/0.5/0.4
0.9
0.3
0.7/0.7

1.2/0.7/0.6/0.5
1.2/0.5/0.4
0.6
0.3
0.7/0.6

129
129
129
132
129

CHRBM100/MT
CHRBM100/TT
CHRBM100/220
CHRBM100/480
CHRBM100/220 50

M57

120
120/208/240/277
120/277/347
220
480
230 / 50

CWA
CWA
CWA
CWA
CWA
CWA

1.3
1.3/0.8/0.7/0.6
1.3/0.6/0.5
0.6
0.4
0.8

1.8
1.8/1.1/0.9/0.8
1.8/0.8/0.7
1.0
0.5
1.1

210
210
210
210
210
210

CHRBM175/120
CHRBM175/MT
CHRBM175/TT
CHRBM175/220
CHRBM175/480
CHRBM175/220 50

M58

120
120/208/240/277
120/277/347
220
480
230 / 50

CWA
CWA
CWA
CWA
CWA
CWA

1.0
1.0/0.6/0.5/0.5
2.2/1.0/0.8
1.4
0.6
1.0

2.6
2.6/1.5/1.3/1.1
2.5/1.1/0.9
1.5
0.6
1.3

294
294
295
295
295
290

CHRBM250/120
CHRBM250/MT
CHRBM250/TT
CHRBM250/220
CHRBM250/480
CHRBM250/220 50

M59

120
120/208/240/277
120/277/347
220
480
230 / 50

CWA
CWA
CWA
CWA
CWA
CWA

3.0
3.5/2.0/1.8/1.5
3.5/1.5/1.2
1.9
0.9
1.4

4.0
4.0/2.2/2.0/1.8
4.0/1.8/1.4
2.2
1.0
2.1

456
458
460
458
462
462

CHRBM400/120
CHRBM400/MT
CHRBM400/TT
CHRBM400/220
CHRBM400/480
CHRBM400/220 50

M47

120/208/240/277
120/277/347
220
480
220/240–50 Hz

CWA
CWA
CWA
CWA
CWA

7.8/4.0/3.7/3.2
7.8/3.2/2.5
3.9
1.9
4.5/4.1

9.0/5.2/4.5/3.9
9.0/3.9/3.2
4.9
2.3
5.0/4.5

1080
1080
1080
1080
1090

CHRBM1000/MT
CHRBM1000/TT
CHRBM1000/220
CHRBM1000/480
CHRBM1000/220 50

M48

120/208/240/277
120/277/347
220
480
220/240–50 Hz

CWA
CWA
CWA
CWA
CWA

13.4/7.7/6.7/5.7
13.4/5.7/4.6
7.3
3.3
6.9/6.3

13.5/7.8/6.8/5.9
13.5/5.9/4.8
7.4
3.4
7.5/6.9

1605
1615
1605
1625
1605

CHRBM1500/MT
CHRBM1500/TT
CHRBM1500/220
CHRBM1500/480
CHRBM1500/220 50

100

175*

250*

400*

L

1000

1500

*Must purchase directly from Advance.

876

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

876-877.qxp

12/16/2013

6:40 PM

Page 877

Fluorescent Data

Ballasts Used With
Eaton's Crouse-Hinds
Luminaires
Luminaire
Series

Lamp Type & Watts

L

Lamp Base

Lamp
No.
Qty.

Ballast
Voltage

Starting
Operating
Amp

Input
Watts

Kit Cat. #

G23

2

120

0.4

22

CHRBF2C018/120

Compact
VF

9W T4

DMVF,
N2MVF,
EVLPF

26W
26W
26W
26W
26W
26W
26W

T4
T4
T4
T4
T4
T4
T4

GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3

2
2
2
2
2
2
2

120
220 / 240
277
347
DC 12V
DC 24V
DC 125V

0.5
0.3
0.2
0.2
3.6
1.8
0.67

55
55
55
44
43
43
55

CHRBF4C084/UNV
CHRBF4C084/UNV
CHRBF4C084/UNV
CHRBF4C084/347
CHRBF4C084/12VDC
CHRBF4C084/24VDC
CHRBF4C084/UNV

DMVF,
N2MVF,
EVLPF

32W
32W
32W
32W
32W
32W
32W

T4
T4
T4
T4
T4
T4
T4

GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3

2
2
2
2
2
2
2

120
220 / 240
277
347
DC 12V
DC 24V
DC 125V

0.6
0.3
0.3
0.2
4.4
2.2
0.67

68
68
68
62
60
60
68

CHRBF4C084/UNV
CHRBF4C084/UNV
CHRBF4C084/UNV
CHRBF4C084/347
CHRBF4C084/12VDC
CHRBF4C084/24VDC
CHRBF4C084/UNV

CPMVF,
DMVF

42W
42W
42W
42W

T4
T4
T4
T4

GX24q-4
GX24q-4
GX24q-4
GX24q-4

2
2
2
2

120
277
347
DC 125V

0.8
0.3
0.3
0.67

93
68
80
93

CHRBF4C084/120
CHRBF4C084/277
CHRBF4C084/347
CHRBF4C084/UNV

Long Twin Tube
40W
40W
40W
40W

T5
T5
T5
T5

2G11
2G11
2G11
2G11

1
1
1
1

120
277
347
120 - 277

0.4
0.2
0.1
0.2

42
42
44
41

CHRBFT80/UNV
CHRBFT80/UNV
CHRBFT80/347
CHRBFT80/UNV

FVS

40W
40W
40W
40W

T5
T5
T5
T5

2G11
2G11
2G11
2G11

2
2
2
2

120
277
347
120 - 277

0.6
0.3
0.2
0.3

76
73
70
74

CHRBFT080/UNV
CHRBFT080/UNV
CHRBFT080/347
CHRBFT080/UNV

36/39W
36/39W
36/39W

2G11
2G11
2G11

2
2
2

120
277
220 / 240

0.6
0.3
0.3

74
74
71

CHRBFT078/120
CHRBFT078/277
CHRBFT078/220

EVFT

L

NFL

Note:
For 3 lamp luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values.
For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

877

878-879.qxp

12/16/2013

L

Luminaire
Series

6:41 PM

Page 878

Fluorescent Data

Ballasts Used With
Eaton's Crouse-Hinds
Luminaires

Lamp Type & Watts

Lamp Base

Lamp
No.
Qty.

Ballast
Voltage

Starting
Operating
Amp

Input
Watts

Kit Cat. #

LINEAR
32W
32W
32W
32W
32W
32W
32W
32W

Med
Med
Med
Med
Med
Med
Med
Med

Bipin
Bipin
Bipin
Bipin
Bipin
Bipin
Bipin
Bipin

1
1
1
1
2
2
2
2

120
277
347
220 / 240
120
277
347
220

0.3
0.2
0.1
0.3
0.5
0.2
0.1
0.4

35
35
32
38
58
58
50
58

CHRBFL064/UNV
CHRBFL064/UNV
CHRBFL64/347
CHRBFL064/UNV
CHRBFL064/UNV
CHRBFL064/UNV
CHRBFL64/347
CHRBFL064/UNV

NFL, FVN,
EVF &
EVFDR

40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12

Med
Med
Med
Med
Med
Med
Med
Med

Bipin
Bipin
Bipin
Bipin
Bipin
Bipin
Bipin
Bipin

1
1
1
1
2
2
2
2

120
277
347
220 50
120
277
347
220 / 240

0.4
0.2
0.2
0.2
0.6
0.3
0.2
0.2

46
46
52
51
73
80
62
71

CHRBFL080/120
CHRBFL080/277
CHRBFL40/347
CHRBFL40/220 50
CHRBFL080/120
CHRBFL080/277
CHRBFL80/347
CHRBFL80/220

FVN

54W T5 HO

Med Bipin

2

120 / 277

NFL, FVN,
EVF &
EVFDR

L

FVN,
EVF &
EVFDR

EVF &
EVFDR

60W
60W
60W
60W
60W
60W

110W
110W
110W
110W

T8
T8
T8
T8
T8
T8
T8
T8

1.03 / 0.43 120 / 117

(800ma)
(800ma)
(800ma)
(800ma)
(800ma)
(800ma)

T12
T12
T12
T12
T12
T12

HO
HO
HO
HO
HO
HO

Recessed
Recessed
Recessed
Recessed
Recessed
Recessed

Double
Double
Double
Double
Double
Double

Contact
Contact
Contact
Contact
Contact
Contact

1
1
1
2
2
2

120
277
220 50
120
277
220 50

0.9
0.5
0.7
1.2
0.5
1.0

79
82
140
133
131
224

CHFBFL120/120
CHFBFL120/277
CHFBFL120/220 50
CHFBFL120/120
CHFBFL120/277
CHFBFL120/220 50

(1500ma)
(1500ma)
(1500ma)
(1500ma)

T12
T12
T12
T12

VHO
VHO
VHO
VHO

Recessed
Recessed
Recessed
Recessed

Double
Double
Double
Double

Contact
Contact
Contact
Contact

1
1
2
2

120
277
120
277

1.7
0.6
2.2
0.9

130
137
230
241

CHRBFL220/120
CHRBFL220/277
CHRBFL220/120
CHRBFL220/277

Note:
For 3 lamp luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values.
For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values.

878

CHRBFL054/UNV

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

878-879.qxp

12/16/2013

6:41 PM

Page 879

1L

Incandescent Luminaires
Hazardous and Non-hazardous

Description

Page No.

Application

see page 880

Class I, Division 1 Hazardous Area Luminaires
EVI Series
Groups C, D

see pages 881–889

EV Series
Groups A, B, C, D

see page 890

Class I, Division 2 and Industrial Luminaires
Vaporgard™ Series

see page 891

V Series

see page 900

NDA Corro•Gard™ Series

see page 904

1L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

879

880-881.qxp

12/23/2013

1L

3:12 PM

Page 880

Incandescent Luminaires
General Information

Applications:

Table 500.8(C)
Identification Numbers

Incandescent luminaires are used:
• Indoors or outdoors in industrial locations; for general area or spot
lighting
• In tunnels, building entrances or similar locations, where moisture,
dirt, chemicals, vibration or rough usage are a problem
• Either mounted directly in the conduit system or attached to cast
outlet boxes, by means of pendant, ceiling, wall bracket or
stanchion mountings
• In areas made hazardous by presence of flammable vapors,
gases, or dusts

Considerations for Selection:
Environmental:
• What is the area classification (NEC)/(CEC) of the location in which
the luminaires will be installed?

Maximum Temperature
Deg. C
450
300
280
260
230
215
200
180
165
160
135
120
100
85

Deg. F

(T Code)

842
572
536
500
446
419
392
356
329
320
275
248
212
185

T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Lighting levels required:
• What wattage fixture(s) will provide the desired light level?
Physical arrangement:

1L

• Type of luminaire mounting needed

880

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Temp. Class

Copyright© 2013 Eaton’s Crouse-Hinds Business

880-881.qxp

12/23/2013

3:12 PM

Page 881

EVI Series Explosionproof
Incandescent Luminaires
Factory Sealed
100–500W Medium and Mogul Base
Applications:
EVI series incandescent luminaires are used:
• For Type 4X, marine, wet location and hose
down environments.
• Where a consistent light level relatively
unaffected by extremes in ambient temperature
(–40°C to +65°C) is required.
• In areas that require lamps to reach full
illumination immediately.
• In areas that require lamps to be frequently
turned on and off.
• Indoors and outdoors in locations which are
hazardous due to the presence of flammable
vapors or gases, ignitible dusts, or ignitible
fibers and flyings.
• Where a luminaire is required for tough
environmental conditions involving corrosives,
water, dust and extreme temperatures.
• Manufacturing plants, heavy industrial facilities,
industrial process facilities such as refineries,
chemical, petrochemical, pharmaceutical and
platforms.
• For lighting of loading docks, tunnels,
stairways, storage closets and task lighting.

Features:

Cl. III & Simultaneous Presence
(Max 150W–Med. base)
Marine and Wet Locations
Type 4X; IP66

1L

Certifications and
Compliances:
• NEC & CEC:
Class I, Division 1, Groups C, D
Class I, Zone 1, Group IIB
Class II, Groups E, F, G
Marine Locations, Wet Locations, Enclosure
Type 4X, IP66
• UL Listed
• cUL Listed (Certified by UL to CSA Standards)
• NEC:
Class III; Simultaneous Presence
• UL Standards:
844 Electric Fixture Hangers for Hazardous
Locations
1598 Luminaires
1598A Luminaires for Installation on Marine
Vessels
• CSA Standards:
C22.2 No. 137

Standard Materials:
• Body, mounting modules and guard –
copper-free aluminum
• Globe – heat and impact-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Reflectors – Krydon® fiberglass-reinforced
polyester

Standard Finishes:
• Copper-free aluminum – Corro-free™ epoxy
powder coat
• Stainless steel – Natural
• Krydon® reflectors – High reflectance white

1L

• Ambient suitability to 65°C.
• Standard 90°C rated building wire for 150W
max 40°C ambient application – represents
more than 75% of all applications.
• Type 4X, marine outdoor locations.
• Factory sealed – no external seals required.
• Quick connect – fixture threads onto the
mounting module for easy installation.
• One size luminaire for all medium base
incandescent lamps through 300W.
• One size luminaire for all mogul base
incandescent lamps through 500W.
• Small compact size – ceiling mount
is 133/4" long.
• Shock absorbing receptacle.
• Easy to assemble and relamp.
• Silicone gaskets seal out dirt and moisture.
• Epoxy powder coat for corrosion resistance.
• Same mounting modules as used with the EVM
and EVLP series.

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E, F, G (Max
150W–Med. base)

Electrical Ratings:
Sources/Wattages
• Medium Base – Maximum 300W (PS25)
• Mogul Base – Maximum 500W (PS40)
Voltages
• Medium Base 120V (250V with suffix /250)
• Mogul Base 277V
Hub Size
• 3/4" or 1" NPT pendant, ceiling, wall mount
• 3/4" NPT bulkhead mount

Options:
Description
• 250V luminaire for export applications
(medium base only)

Suffix
/250

Accessories:
• Reflectors – For Ordering by Components
see page 883.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

881

882-883.qxp

12/16/2013

1L

6:41 PM

Page 882

EVI Series Explosionproof
Incandescent Luminaires
Factory Sealed
100–500W Medium and Mogul Base

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E, F, G (Max
150W–Med. base)

Cl. III & Simultaneous Presence
(Max 150W–Med. base)
Marine and Wet Locations
Type 4X; IP66

EVI501 Series
Mogul Base with
EV503 Guard
(Max. 500W PS40)
EVIA2501
EVIA3501

Hub
Size
3
/4"
1"

Ceiling Mount

3

/4"
1"

EVICX2301
EVICX3301

EVICX2501
EVICX3501

Wall Mount

3

/4"
1"

EVIBX2301
EVIBX3301

EVIBX2501
EVIBX3501

Bulkhead Mount

3

/4"
1"

EVIBH2301
—

—
—

Stanchion Mount

11/4"

EVIJ4301

EVIJ4501

EVI301

EVI501

1L

Mounting
Style
Pendant Mount

EVI301 Series
Medium Base with
EV505 Guard
(Max. 300W PS25)
EVIA2301
EVIA3301

Luminaire with
Guard Less
Mounting Module

Note:

882

Medium base luminaires (EVI301 Series) – For A19 lamps up to 100W, use Leviton socket extension Leviton catalog number 2005.
Mogul base luminaires (EVI501 Series) – For PS30 medium base lamps, use Eaton's Wiring Devices socket adapter catalog number 332.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

882-883.qxp

12/16/2013

6:41 PM

Page 883

EVI Series Explosionproof
Incandescent Luminaires

1L

Ordering By Components

Factory Sealed
100–500W Medium and Mogul Base
EVI Luminaires are available in components.
A complete luminaire consists of:
I.

Mounting Module

II.

EVI Luminaire Body and Globe Assembly

III.

Guard, Reflector

I. Mounting Module:
Type
Pendant

Conduit

Cat. #

3

/4"
1"

EVMP2
EVMP3

Ceiling and Wall Box

3

/4"
1"

EV22
EV33

Wall Bracket Arm

3

/4"
1"

EV22 & EV87
EV33 & EV87

Stanchion

11/4"

EVMJ4

Bulk Head

3

/4"

EVIJ2

II. Luminaire Body and Globe Assembly with Guard:
Type

Cat. #

Medium Base

EVI301

Mogul Base

EVI501

III. Guards and Reflectors:
Type

Cat. #

Guard – Fits EVI301 Series (medium base)

EV505

Guard – Fits EVI501 Series (mogul base)

EV503

Dome Reflector – Fits EVI301 Series (medium base)

RD636

Angle Reflector – Fits EVI301 Series (medium base)

RA636

Dome Reflector – Fits EVI501 Series (mogul base)

RD739

Angle Reflector – Fits EVI501 Series (mogul base)

RA739

1L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

883

884-885.qxp

12/16/2013

1L

6:42 PM

Page 884

EVI Series Explosionproof
Incandescent Luminaires

Family Tree
Temperature Performance Data

Factory Sealed
100–500W Medium and Mogul Base

Temperature Performance Data:
Type

Watts/Lamp

Class I, Div. 1
(Class I, Zone 1)
Ambient

EVI301
Medium
Base

100W/A21 or A19
150W/A21
200W/A23 or A25
300W/PS25
200W/PS30
300W/PS35
500W/PS40

40°C
T4
T4
T3
T3
T4A
T4
T3A

65°C
T3C
T3C
T2C
T2C
T4
T3C
T3

Simultaneous
Presence
Ambient

Supply Wire
Temp (°C)
Ambient

40°C
T3C
T3C
—
—
T3A
—
—

40°C
T3C
T3C
—
—
T3A
—
—

40°C
90°C
90°C
105°C
105°C
90°C
90°C
105°C

1L

EVI501
Mogul
Base

55°C
T3C
T3C
T2D
T2D
T4
T3C
T3

Class II
Ambient

884

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

55°C
105°C
105°C
125°C
125°C
90°C
90°C
125°C

65°C
125°C
125°C
125°C
125°C
105°C
105°C
125°C

884-885.qxp

12/16/2013

6:42 PM

Page 885

EVI Series Explosionproof
Incandescent Luminaires

1L

Medium Base Dimensions and Weights

Factory Sealed
100–500W Medium and Mogul Base
Medium Base EVI Luminaire
Dimensions In Inches:
Pendant Mount

Stanchion Mount

Ceiling Mount

Wall Mount

Bulkhead Mount

1L

Medium Base Net Luminaire Weights (lbs.):
EVI301 with guard

11 lbs.

Add mounting modules:
Pendant
Ceiling
Wall
Bulkhead
Stanchion

1.0
2.0
4.5
2.2
2.5

lbs.
lbs.
lbs.
lbs.
lbs.

www.crouse-hinds.com

Add for reflectors:
RD636 (Dome Reflector, Small)
RA636 (Angle Reflector, Small)
RD739 (Dome Reflector, Small)
RA739 (Angle Reflector, Small)

US: 1-866-764-5454

CAN: 1-800-265-0502

1.5
1.0
2.0
1.4

lbs.
lbs.
lbs.
lbs.

Copyright© 2013 Eaton’s Crouse-Hinds Business

885

886-887.qxp

12/16/2013

1L

6:42 PM

Page 886

Mogul Base Dimensions and Weights

EVI Series Explosionproof
Incandescent Luminaires
Factory Sealed
100–500W Medium and Mogul Base

Mogul Base EVI Luminaire
Dimensions In Inches:
Pendant Mount

Ceiling Mount

Stanchion Mount

1L

Wall Mount

Mogul Base Net Luminaire Weights (lbs.):
EVI501 with guard

24 lbs.

Add mounting modules:
Pendant
Ceiling
Wall
Bulkhead
Stanchion

1.0
2.0
4.5
2.2
2.5

886

www.crouse-hinds.com

lbs.
lbs.
lbs.
lbs.
lbs.

US: 1-866-764-5454

Add for reflectors:
RD636 (Dome Reflector, Small)
RA636 (Angle Reflector, Small)
RD739 (Dome Reflector, Small)
RA739 (Angle Reflector, Small)

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1.5
1.0
2.0
1.4

lbs.
lbs.
lbs.
lbs.

886-887.qxp

12/16/2013

6:42 PM

Page 887

EVI Series Explosionproof
Incandescent Luminaires

Photometric Data

1L

Factory Sealed
100–500W Medium and Mogul Base
Medium Base
Luminaire with Globe and Guard
EVICX2301 Lamp: 300W/PS25 Incandescent

Medium Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVICX2300 Lamp: 300W/PS25 Incandescent

1L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

887

888-889.qxp

12/16/2013

1L

6:42 PM

Page 888

EVI Series Explosionproof
Incandescent Luminaires

Photometric Data

Factory Sealed
100–500W Medium and Mogul Base
Medium Base
Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVICX2300 Lamp: 300W/PS25 Incandescent

Mogul Base
Luminaire with Globe and Guard

1L

EVIA2501 Lamp: 500W/PS40 Incandescent

888

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

888-889.qxp

12/16/2013

6:42 PM

Page 889

EVI Series Explosionproof
Incandescent Luminaires

Photometric Data

1L

Factory Sealed
100–500W Medium and Mogul Base
Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVIA2500 Lamp: 500W/PS40 Incandescent

Mogul Base
Luminaire with Globe and Angle Reflector (Less Guard)
EVIA2500 Lamp: 500W/PS40 Incandescent

1L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

889

890-891.qxp

12/23/2013

1L

3:12 PM

Page 890

Cl. I, Div. 1 and 2, Groups A, B, C, D – Pendant Mount
Cl. I, Div. 1 and 2, Groups B, C, D – Ceiling and Bracket Mount
Wet Locations
NEMA 3, 3R

EV Incandescent
Luminaires
Factory Sealed

Applications:
EV292 Series luminaires are used:
• To provide incandescent lighting in locations
made hazardous due to the presence of
hydrogen, gases or vapors of an equivalent
hazard, such as manufactured gas
• Hydrogen areas of process industries, missile
bases where hydrogen fuel is used and gas
manufacturing plants
• In areas of lesser hazard than indicated above
• EVA292 pendant mount luminaire is also
suitable for use in locations made hazardous
due to the presence of acetylene

Features:
• Flametight threaded joints – no external seal
needed
• Easy to assemble and relamp
• Shock absorbing receptacle
• Gasket seals out dirt and liquids
• Positive locking of globe holder
• Heat and impact resistant globe
• Inner reflector eliminates upward spill light
• Lightweight
• Corrosion resistant
• Dome and 30° angle reflectors available

Certifications and
Compliances:

1L

• NEC/CEC:
Class I, Divisions 1 and 2, Groups
A, B, C, D – pendant mount
Class I, Divisions 1 and 2, Groups
B, C, D – ceiling and bracket mount
• UL Standard: 844
• CSA Standard: C22.2 No. 137

Standard Materials:

Pendant style
with RD725 dome reflector

Pendant style
with RA725 30° angle
reflector

Pendant style
without reflector

Ordering Information:
Style

Max.
Lamp
Size

Without
Dome
Hub
Reflector Reflector
Size (In.) Cat. #
Cat. #

Pendant

300 watt,
PS-30
(medium base)

With
Guard

3

Ceiling

300 watt,
PS-30
(medium base)

With
Guard

3

Bracket

300 watt,
PS-30
(medium base)

With
Guard

3

30° Angle
Reflector
Cat. #

/4

EVA292

RD725

RA725

/4

EVCX292 RD725

RA725

/4

EVBX292

Not Applicable

Dimensions
In Inches:

• Globes – heat and impact resistant glass
• Luminaire and bracket arm – copper-free
aluminum
• Reflectors – Krydon® fiberglass-reinforced
polyester
• Back box – Feraloy® iron alloy

Standard Finishes:
• Aluminum – epoxy powder coat
• Krydon – high reflectance white
• Feraloy – electrogalvanized and aluminum
acrylic paint

EVA

EVBX

EVCX

EVCX

Size Ranges:
• 3/ 4" conduit hub

Capacity Ranges:
• 300 watt, PS-30 medium base lamps

Temperature Performance
Data:

a
b
c

EVA
87/8
163/8
147/8

EVBX

EVCX

Reflector
Type

Diameter

87/8
181/8
165/8

87/8
143/8
127/8

Dome
30° Angle

16"
16"

Class I
Ambient
Supply
Style
UL
Temp. °C
Wire °C
Pendant T3A
25 / 40
150°C
Ceiling
T3A
25 / 40
150°C
Bracket
T3A
25 / 40
150°C
Note: Photometric curves and data are the same as shown for EV Groups C, D series.
890

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

890-891.qxp

12/23/2013

3:12 PM

Page 891

Cl. I, Div. 2, Groups A, B, C, D
(All mounting except stanchion)
Wet Locations
NEMA 3, 3R

VAPORGARD™ Incandescent
Luminaires

Applications:
Vaporgard series incandescent luminaires
are used:
• Indoors or outdoors in industrial
locations where enclosed and gasketed
fixtures are required
• In tunnels, building entrances and similar
locations, where moisture, dirt,
chemicals, vibration or rough usage are a
problem
• For flush or surface mounting on ceiling
or wall; pendant or in conduit systems;
with or without a cast outlet box

Features:

Certifications and
Compliances:
• Wet locations
• NEC/CEC:
Class I, Division 2
• UL Standard: 1598
• CSA Standard: C22.2 No. 9
• UL/CSA Fixture Fitting

Standard Materials:
• Bodies and guards – copper-free
aluminum
• Globes
-Heat and impact resistant
tempered glass
-Colored glass non-tempered
(G55, G56, G57, G58)
-Plastic polycarbonate
(G63, G65, G67)
• Reflectors – Krydon® fiberglassreinforced polyester

Standard Finishes:
• Bodies and guards – epoxy powder coat
• Krydon material – high reflectance white

Options:
The following options are available from
the factory by adding suffix to fixture
Cat. No.:
Description
Suffix
• Teflon coating on globe
for increased shatter
protection (G24 globe
200 watt series only) ............
S808
• 250V nameplate for
export applications...............
/250
• Plastic polycarbonate
see
globe .................................... page 894

1L

• Designed to exclude dirt, moisture and
corrosive vapors from the interior of the
luminaires and the conduit system
• There are no screws to remove as the
shock-absorbing socket strap is keyhole
slotted and removes quickly for ease of
wiring
• The glass globe-guard assembly is
installed and/or removed as a unit,
making it necessary to handle only one
piece in relamping
• There are no crevices to accumulate a
dirt or dust build-up and fixture has an
attractive finish with a smooth, dust and
dirt shedding design
• Configurated glass globe has vertical
fluting and stippled bottom which
provides for more even light distribution
and glare elimination
• For non-hazardous locations,
shatterproof plastic polycarbonate
globes are available for use with the 200
watt series
• Reversible offset socket mounting strap
permits use of various size lamps while
holding light center in same position for
maximum light output and efficiency
• Shock absorbing medium base lamp
socket
Krydon® fiberglass-reinforced polyester
reflectors:
• Reflectance is equivalent to the finest
porcelain enamel
• Cannot corrode – no enamel to chip and
rust
• Ultraviolet inhibitors are incorporated in
the material to prevent discoloration and
brittleness

1L

Ratings (Electrical/Size):
• Up to 300 watt, PS-30 medium base
lamp
• 1/2" to 11/4" hubs
• 120V nameplate is standard – for NEC
compliance
• 250V nameplate is optional. Supplied
when ordered with suffix: /250

Class I, Division 2
Temperature
Performance Data:
(Based on 40°C ambient)
Lamp Watts
150
200
300

www.crouse-hinds.com

T-Number

Supply
Wire °C

T2A
T2B
T2B

150°C
200°C
150°C

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

891

892-893.qxp

12/16/2013

6:43 PM

Page 892

VAPORGARD™ Incandescent
Luminaires

1L

Cl. I, Div. 2, Groups A, B, C, D
Wet Locations
NEMA 3, 3R

Enclosed and Gasketed
Pendant Mount –
VDA Series
Series

Max.
Lamp Size

Complete Cat. #
with globe/guard

Luminaire Components Cat. #s
Pendant
Body
Globe
Guard

150
150
150

150 watt
A-21

VDA15GP
VDA25GP
VDA35GP

VDA15
VDA25
VDA35

G54
G54
G54

P50
P50
P50

3

/2"
/4"
1"

200
200
200

200 watt
A-23

VDA12GP
VDA22GP
VDA32GP

VDA12
VDA22
VDA32

G24
G24
G24

P21
P21
P21

/2"
/4"
1"

300
300
300

300 watt
PS-25 & PS-30

VDA13GP
VDA23GP
VDA33GP

VDA13
VDA23
VDA33

G34/G251
G34/G251
G34/G251

P22
P22
P22

Max.
Lamp Size

Complete Cat. #
with globe/guard

Luminaire Components Cat. #s
Thru-Feed
Body
Globe
Guard

VDC25GP

VDC25

G54

P50

VDC22GP

VDC22

G24

P21

VDC23GP

VDC23

G34/G251

P22

Max.
Lamp Size

Complete Cat. #
with globe/guard

Luminaire Components Cat. #s
Lamp
Socket Body
Globe
Guard

150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30

VXH15GP

VXH15

G54

P50

VXH12GP

VXH12

G24

P21

VXH13GP

VXH13

G34/G251

P22

Max.
Lamp Size

Complete Cat. #
with globe/guard

Luminaire Components Cat. #s
Lamp
Socket Body
Globe
Guard

Junction
Box

VXHF25GP

VXH15

G54

P50

VXF20

VXHF22GP

VXH12

G24

P21

VXF20

VXHF23GP

VXH13

G34/G251

P22

VXF20

Hub
Size
/2"
3
/4"
1"
1

1

1
3

Thru-Feed –
VDC Series
Hub
Size

Series

/2 or 3/4"

150

/2 or /4"

200

/2 or 3/4"

300

1

1

3

1

150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30

Ceiling Mount for
Recessed 4" Round
Box – VXH Series
1L

Series
150
200
300

Ceiling Mount with
Junction Box –
VXHF Series
Hub
Size

Series

/2 or 3/4"

150

/2 or 3/4"

200

/2 or 3/4"

300

1

1

1

150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30

Note: All fixtures supplied with 1/2" reducers, except for pendant mount.

892

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

892-893.qxp

12/16/2013

6:43 PM

Page 893

VAPORGARD™ Incandescent
Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Wet Locations
NEMA 3, 3R

1L

Enclosed and Gasketed

Wall Mount –
VXHT Series

Hub
Size

Series

/2 or 3/4"

150

/2 or 3/4"

200

/2 or 3/4"

300

1

1

1

Max.
Lamp Size
150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30

Complete Cat. #
with globe/guard

Luminaire Components Cat. #s
Wall
Bracket
Mounting
Module
Body
Globe
Guard

VXHT25GP

VXT20

VXH15 G54

P50

VXHT22GP

VXT20

VXH12 G24

P21

VXHT23GP

VXT20

VXH13 G34/G251 P22

Wall Mount –
Adapter Kit
Description

Cat. #

Mounts wall mount VXHT Series
to a 4" Round Box

VXT K1

Wall Mount with
Junction Box –
VXHBF Series

Hub
Size

Series

/2 or 3/4"

150

/2 or /4"

200

/2 or 3/4"

300

1

1

1

3

Junction
Box

VXHBF25GP

VXT20

VXH15 G54

P50

VXF20

VXHBF22GP

VXT20

VXH12 G24

P21

VXF20

VXHBF23GP

VXT20

VXH13 G34/G251 P22

VXF20

Max.
Lamp Size

Complete Cat. #
with globe/guard

Luminaire Components Cat. #s
Stanchion
Mounting
Module
Body
Globe
Guard

150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30

VXHA45GP

VXA4

VXH15 G54

P50

VXHA42GP

VXA4

VXH12 G24

P21

VXHA43GP

VXA4

VXH13 G34/G251 P22

Max.
Lamp Size
150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30

1L

Complete Cat. #
with globe/guard

Luminaire Components Cat. #s
Wall
Bracket
Mounting
Module
Body
Globe
Guard

Stanchion Mount –
VXHA Series
Hub
Size
11/4"
11/4"
11/4"

Series

Note: All fixtures supplied with 1/2" reducers, except for pendant mount.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

893

894-895.qxp

12/16/2013

6:43 PM

Page 894

VAPORGARD™ Incandescent
Luminaires

1L

Parts and Accessories
Medium Base Lamp
Receptacle with Strap

Plastic Globes✪

Globes‡ and Guards

Shock Absorbing

Description

Cat. #

Shock Absorbing Medium Base
Lamp Receptacle with Strap

V84

Shatterproof
polycarbonate
plastic globe†
150 and 200W
globe

300W globe

Applications:

Max. Lamp Size

Reflectors

Color
Clear
(heatresisting)
Green
Blue
Red
Amber

Dome

200 Watt,
A-23,
150 Watt, A-25,
A-21
PS-25
Cat. #
Cat. #

300 Watt,
PS-25,
PS-30■
Cat. #

G54

G24

G34G251

G55*
G56*
G57*
G58*

G25
G26
G27
G28

Guards for Glass Globes
(Not for use with plastic globes)

1L

30° Angle

Max. Lamp Size

Dome
Cat. #

30° Angle
Cat. #

150 watt, A-21

RD64

RA64

200 watt, A-23,
A-25, PS-25 and
300 watt, PS-30

RD71

RA71

VXFT – 5 Hubs, 4 Plugs

Guard P50 and P21

Guard P22

For use in:
• Food processing plants and canneries,
dairies, breweries and bakeries
• Emergency lighting

Features:
• Shatterproof, which precludes
contamination of food products with
broken particles of glass
• Designed to comply with U.S. Dept. of
Agriculture specification for food
processing plants
• Provides protection against vandalism,
with resultant lower replacement and
maintenance costs
• Particularly adaptable for use on
emergency police or fire alarm boxes
• Same size as G24 series glass globes.
Existing installations can be changed to
plastic globes simply by replacing globe
• For use with 200 watt series luminaires
such as VDA22, etc.
• For use without guard

Color

Max. Wattage,
Lamp Size

Cat. #

Natural
Green
Red

200 watt, A-23
200 watt, A-23
200 watt, A-23

G63
G65
G67

Note: Polycarbonate globes for non-hazardous
locations only.

Hub Size (In.)

Cat. #

/2
3
/4

VXFT10
VXFT20

1

Max. Lamp Size

Cat. #

150 watt, A-21
200 watt, A-23, A-25, PS-25
300 watt, PS-30 (with G251 only)

P50
P21
P22

Mounting Adapter Kit

For use when rear wiring entry is required.
Use in lieu of VXF10 or VXF20.

VXT-K1

†Prior to wash-down, globes must be cool.
✪Lamp must be mounted in vertical position base up to 45°C (stanchion) only.
*With G55, G56, G57, G58 color globes, maximum lamp size is 60 watt for outdoor applications.
§G24 is available with a TEFLON® coating for increased shatter protection by adding suffix S808 (stanchion) only.
■Globe G251 required when guard P22 is used. Use globe G34 when guard is not used.
‡All glass globes are configured type, having fluted side and stippled bottom.

894

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Description

Cat. #

Allows for the mounting of nonEaton's Crouse-Hinds outlet
boxes to the VXT20 wall mount
bracket and VXH ceiling mount
bracket

VXT K1

Copyright© 2013 Eaton’s Crouse-Hinds Business

Page 895
6:43 PM
12/16/2013
894-895.qxp

150W
VDA15
VDA25
VDA35

200W
VDA12
VDA22
VDA32

300W
VDA13
VDA23
VDA33

PENDANT
VDA/VFA

FLUORESCENT
VFA122
VFA222
VFA322

300W
VDC23

FLUORESCENT
VFC222
VXH12 VXH13

200W
VFH122

FLUORESCENT

300W

VXH15

150W

G24

P21

PLATE
0305729
VXT-K1

GASKET
0305017

150W
VXHBF25

200W
VXHBF22

300W
VXHBF23

1L

RA71

CLEAR HEAT RESISTING

WALL & JUNCTION BOX
VXHBF/VFHBF

300W GLOBE
WITH GUARD

G251 GLOBE
&
P22 GUARD

ADAPTER KIT FOR MOUNTING VXT20 AND
VXH15, VXH12, VXH13, VFH122 TO
4" OULET BOX (BY OTHERS)

FLUORESCENT
VFHF222

RD71

CLEAR HEAT RESISTING

G34

300W GLOBE
WITHOUT GUARD

300W
VXHF23

VXF20
VXFT20 (ORDER SEPARATELY)

VXH15
VXH12
VXH13
VFH122

200W
VXHF22

VXHF/VFHF

BOX MOUNTING

150W
VXHF25

VXH1/VFH1

BOX MOUNTING

RA64

(NO GUARD AVAILABLE WHEN
ORDERED WITH PLASTIC GLOBE)

G24 CLEAR HEAT RESISTING
G25 GREEN
G26 BLUE
G27 RED
G28 AMBER
G63 CLEAR PLASTIC POLYCARBONATE
G65 GREEN PLASTIC POLYCARBONATE
G67 RED PLASTIC POLYCARBONATE

FLUORESCENT &
200W
GLOBE & GUARD

VDC/VFC

P50

G54

150W
GLOBE & GUARD

THRU FEED

150W
200W
VDC25 VDC22

G54 CLEAR HEAT RESISTING
G55 GREEN
G56 BLUE
G57 RED
G58 AMBER

RD64

VXT20

VXH15
VXH12
VXH13
VFH122

VFHBF222

FLUORESCENT

0305016

GASKET

VXF20
VXFT20
300W
200W
150W
VXHT25 VXHT22 VXHT23

WALL MOUNT
VXHT/VFHT

FLUORESCENT
VFHT222

150W

300W

VXA4

VXH15
VXH12
VXH13
VFH122

200W

VXHA45 VXHA42 VXHA43

VFHA422

FLUORESCENT

VXHA4/VFHA4

ANGLE ADAPTER
STANCHION MOUNT

895

Copyright© 2013 Eaton’s Crouse-Hinds Business

CAN: 1-800-265-0502

US: 1-866-764-5454

www.crouse-hinds.com

1L
Family Tree

VAPORGARD™ Incandescent
Luminaires

896-897.qxp

1L

12/16/2013

6:43 PM

Page 896

Photometric Data

VAPORGARD™ Incandescent
Luminaires

Luminaire VXHA45GPRA

Luminaire With Globe, 30° Angle Reflector
and With or Without Guard

Lamp: 150W/A-21
Total Bare Lamp Lumens: 2850
Total
Lumens Eff. %
With
Guard

1490

52.3

Without
Guard 1881

66.0

Lamp: 100W/A-21 through 200W/A-23
Total Bare Lamp Lumens: 4000
All data provided is for 200W/A-23 incandescent lamp. Use following candlepower/lumen
multipliers for other lamp sizes:
100W 0.42; 150 W0.7

Measurements taken from A-A' plane.

Measurements taken from A-A' plane.

Luminaire VXHA42GPRA
Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6300
Total
Lumens

Eff. %

3630

57.6

Without
Guard 4271

67.8

With
Guard

Lamp
Size

Without Guard
Total
Lumens
Eff. %

With Guard
Total
Lumens
Eff. %

100W
150W
200W/A-23
200W/PS-25

1141
1890
2700
2174

949
1582
2260
1819

67.5

56.5

1L

Luminaire With Globe, 30° Angle Reflector
and With or Without Guard
Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6000

Measurements taken from A-A' plane.

Total
Lumens

Eff. %

With
Guard

3360

56.0

Without
Guard

3954

65.9

Measurements taken from A-A' plane.

896

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

896-897.qxp

12/16/2013

6:43 PM

Page 897

Photometric Data

VAPORGARD™ Incandescent
Luminaires

1L

Lamp: 100W/A-21 through 200W/PS-25
Total Bare Lamp Lumens: 4000
All data provided is for 200W/A-23 incandescent lamp. Use following candela/lumen multipliers for other lamp sizes:
100W 0.42; 150W 0.7; 200W/PS-25 0.82

Luminaire With Globe and With or Without
Guard

Luminaire With Globe, Dome Reflector and
With or Without Guard
Example: Zonal Lumens for
200W/A-23 lamp with guard
for 0–40° is 948 Zonal
Lumens for 150W lamp with
guard for 0–40° is 948 x 0.7
= 664.

Example: Zonal Lumens for
200W/A-23 lamp with guard
for 0–40° is 272 Zonal
Lumens for 150W lamp with
guard for 0–40° is 272 x 0.7
= 190.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

% Reflectance
Eff. Ceil.
Wall

4

5

80

50
30
10

.654
.608
.567

.549
.486
.432

.471
.400
.345

.407
.333
.277

.353
.282
.228

70

50
30
10

.603
.563
.523

.506
.449
.401

.434
.370
.320

.375
.309
.257

50

50
30
10

.509
.477
.449

.424
.380
.341

.363
.313
.271

30

50
30
10

.422
.399
.376

.349
.315
.285

10

50
30
10

.343
.324
.307

.280
.253
.230

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.604
.576
.552

.522
.480
.444

.454
.404
.364

.395
.340
.298

.347
.290
.248

.326
.260
.211

70

50
30
10

.591
.565
.543

.512
.472
.440

.445
.398
.361

.387
.336
.296

.339
.286
.246

.312
.260
.218

.273
.220
.179

50

50
30
10

.564
.544
.526

.490
.457
.428

.428
.387
.354

.372
.327
.292

.327
.280
.245

.297
.259
.225

.255
.214
.180

.223
.180
.147

30

50
30
10

.541
.525
.509

.470
.444
.419

.411
.377
.348

.358
.319
.288

.315
.273
.241

.237
.206
.180

.202
.170
.143

.176
.142
.115

10

50
30
10

.521
.507
.494

.452
.429
.409

.396
.367
.342

.345
.311
.283

.304
.268
.238

Room Cavity Ratio
6
7
8

9

10

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.315
.244
.193

.279
.210
.164

.249
.183
.137

.226
.162
.118

.201
.140
.100

80

50
30
10

.309
.253
.214

.274
.220
.184

.244
.192
.155

.222
.170
.135

.193
.142
.110

70

50
30
10

.289
.225
.177

.257
.194
.150

.230
.170
.127

.208
.150
.110

.185
.130
.093

70

50
30
10

.303
.250
.211

.270
.217
.181

.241
.191
.154

.219
.168
.135

.189
.142
.110

50

50
30
10

.242
.189
.150

.215
.163
.126

.192
.143
.106

.175
.126
.092

.156
.109
.077

50

50
30
10

.291
.245
.209

.260
.212
.179

.232
.186
.153

.211
.166
.134

.184
.139
.109

30

50
30
10

.198
.155
.123

.175
.134
.102

.158
.116
.086

.143
.103
.075

.128
.088
.061

30

50
30
10

.281
.239
.207

.250
.209
.177

.225
.182
.152

.204
.162
.133

.178
.136
.107

10

50
30
10

.157
.122
.096

.140
.106
.080

.124
.091
.066

.114
.080
.057

.101
.068
.045

10

50
30
10

.272
.234
.205

.243
.205
.175

.217
.179
.150

.198
.159
.131

.173
.134
.106

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

US: 1-866-764-5454

% Reflectance
Eff. Ceil.
Wall

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1L

Room Cavity Ratio
1
2
3

897

898-899.qxp

12/16/2013

6:44 PM

Page 898

VAPORGARD™ Incandescent
Luminaires

1L

Photometric Data

Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6000

Luminaire With Globe Only

Luminaire With Globe and Dome Reflector

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

1L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.692
.644
.602

.582
.515
.459

.499
.425
.367

.431
.354
.295

.373
.300
.243

70

50
30
10

.636
.594
.552

.534
.475
.425

.458
.392
.339

.396
.327
.273

50

50
30
10

.532
.500
.470

.444
.398
.358

.380
.328
.285

30

50
30
10

.437
.412
.389

.362
.326
.295

10

50
30
10

.350
.331
.313

.285
.258
.235

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.766
.734
.706

.671
.621
.579

.587
.528
.482

.514
.448
.398

.454
.385
.334

.345
.276
.223

70

50
30
10

.750
.720
.694

.657
.610
.573

.577
.521
.477

.505
.444
.395

.443
.380
.332

.327
.272
.229

.286
.230
.188

50

50
30
10

.717
.693
.672

.630
.592
.558

.555
.507
.468

.485
.432
.390

.429
.372
.329

.308
.268
.234

.264
.222
.186

.230
.186
.152

30

50
30
10

.688
.670
.651

.606
.575
.546

.535
.494
.460

.468
.422
.385

.414
.364
.325

.241
.210
.183

.205
.172
.145

.179
.144
.116

10

50
30
10

.663
.647
.632

.584
.557
.534

.516
.482
.452

.452
.412
.379

.400
.357
.321

Room Cavity Ratio
6
7
8

9

10

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.333
.258
.205

.295
.223
.173

.263
.194
.145

.238
.170
.125

.212
.147
.105

80

50
30
10

.404
.337
.289

.360
.294
.250

.322
.258
.212

.293
.229
.185

.254
.191
.151

70

50
30
10

.305
.238
.188

.271
.204
.158

.241
.178
.133

.219
.157
.115

.194
.136
.097

70

50
30
10

.397
.333
.285

.354
.290
.246

.317
.256
.211

.288
.227
.185

.249
.191
.151

50

50
30
10

.253
.198
.157

.224
.170
.132

.200
.148
.110

.181
.131
.095

.162
.113
.079

50

50
30
10

.383
.326
.283

.342
.284
.244

.306
.250
.209

.279
.223
.184

.243
.187
.150

30

50
30
10

.204
.160
.127

.180
.138
.105

.162
.119
.088

.146
.105
.075

.130
.090
.061

30

50
30
10

.371
.320
.281

.330
.280
.241

.297
.245
.208

.270
.218
.182

.235
.184
.148

10

50
30
10

.158
.123
.096

.141
.106
.079

.124
.091
.066

.114
.080
.055

.101
.067
.044

10

50
30
10

.359
.313
.277

.322
.275
.239

.288
.241
.206

.262
.215
.180

.229
.181
.146

% Reflectance
Eff. Ceil.
Wall

898

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

% Reflectance
Eff. Ceil.
Wall

% Reflectance
Eff. Ceil.
Wall

Copyright© 2013 Eaton’s Crouse-Hinds Business

898-899.qxp

12/16/2013

6:44 PM

Page 899

VAPORGARD™ Incandescent
Luminaires

1L

Dimensions
Dimensions in Inches
a
b
c
d
e
f
g
h
j

150 watt,
A-21
127/8
111/8
53/8
313/16
87/16
12
813/16
9
41/2

200 watt,
PS-25

300 watt,
PS-30

167/8
145/8
6
4
91/8
14
101/2
1013/16
611/16

167/8
145/8
6
4
91/8
14
12
131/8
611/16

VDA Series

VDC Series

VXH and VXHF Series
(Omit box for VXF Series)

1L

VXHT and VXHBF Series
(Omit box for VXHB series)

Dimensions in Inches
Max. Lamp Size
150 watt, A-21
200 watt, A-23, A-25, PS-25
and 300 watt, PS-30

a
53/8
6

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

899

900-901.qxp

12/16/2013

6:44 PM

Page 900

Wet Locations
NEMA 3, 3R

V-Series Incandescent
Luminaires

1L

Enclosed and Gasketed
Applications:

Standard Materials:

V-Series incandescent luminaires are used:
• Indoors or outdoors in industrial
locations where enclosed and gasketed
fixtures are required
• In tunnels, building entrances and similar
locations, where moisture, dirt,
chemicals, vibration or rough usage are
a problem
• For flush or surface mounting on ceiling
or wall, with or without a cast outlet box,
pendant or in conduit systems

•
•
•
•

Features:

Bodies – Feraloy® iron alloy
Guards – copper-free aluminum
Globes – glass
Reflectors – Krydon® fiberglassreinforced polyester material reflectors

Standard Finishes:
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint
• Copper-free aluminum – natural
• Krydon® material – high reflectance white

Options:

• Designed to exclude dirt, moisture and
corrosive vapors from the interior of the
fixtures and the conduit system
• Several body styles provide a wide
variety of mountings, while all use the
same globes, guards and optional
accessories
• Rugged and corrosion resistant

Size Ranges:

Certifications and
Compliances:

• 3/4 hubs
• Maximum wattage lamp:
– Glass globes 150W, A23
– Polycarbonate 75W, A33

Description
Corro-free™ epoxy
powder coat

Suffix
S752

Plastic polycarbonate
globe

Order separately.
See below

1L

• Wet locations
• NEMA: 3, 3R
• UL Standard: 1598

Description

VDA

VC

VG

VJ

VD

Cat. #

Cat. #

Cat. #

Cat. #

Cat. #

With plain globe and
guard

VDA2759

VC2759

VG2759

VJ2759

VD2759

Without globe and
guard

VDA275

VC275

VG275

VJ275

VD275

Glass Globes and Guards

Polycarbonate Globes
Applications:
Polycarbonate globes are used:
• In food processing plants,
canneries, dairies, breweries and
bakeries
• In emergency lighting
• Emergency police and fire alarm
boxes

V63
Color
Clear (heat
resisting)
Green
Blue
Red
Amber
900

V911
Cat. #

Globe
Size

V63

6 /4"
3

Cat. #
V911

VN72
VN73
VN75
VN76
www.crouse-hinds.com

US: 1-866-764-5454

Features:
• Polycarbonate globes are
shatterproof, preclude
contamination of food products
with broken particles of glass
• Comply with U.S. Dept. of
Agriculture specification for food
processing plants

CAN: 1-800-265-0502

V470
Color

Cat. #

Natural
Red

V470
V475

Copyright© 2013 Eaton’s Crouse-Hinds Business

900-901.qxp

12/16/2013

6:44 PM

Page 901

1L

Incandescent Luminaires
Accessories and Parts For V-Series

Reflectors

Receptacles

Krydon® – fiberglass-reinforced
polyester
(Must be used with V911 Guard)

(medium base)

Dome

Description

Cat. #

Medium Base Receptacle

V46

Gasket

Angle
Lamp Size
Dome
50–150W
30°Angle
50–150W
Note:

Dia.

Cat. #

12"

RD60

12"

RA60

Description

Cat. #

Gasket

GASK213

Angle reflector cannot always be used with
bracket style fixtures. Check distance from
mounting surface to center of body against
reflector size to determine if reflector will fit.

1L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

901

902-903.qxp

12/16/2013

6:44 PM

Page 902

V-Series Incandescent
Luminaires

1L

Enclosed and Gasketed
Dimensions
Dimensions
In Inches:

VC

VD

a

c

d

h

k

/8
7
/8

311/16
311/16

4
4

63/16
63/16

49/16
49/16

7

Hub
Size
1
/2
3
/4

a

b

c

g

h

k

415/16
415/16

43/16
43/16

515/16
63/16

21/2
23/4

63/16
63/16

49/16
49/16

1L

Hub
Size
1
/2
3
/4

VDA

VG
Hub
Size
1
/2
3
/4

902

VJ

c

h

k

47/8
47/8

63/16
63/16

49/16
49/16

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Hub
Size
1
/2
3
/4

b

c

d

e

h

k

113/16
113/16

47/8
47/8

3

/8
3
/8

53/8
53/8

63/16
63/16

49/16
49/16

Copyright© 2013 Eaton’s Crouse-Hinds Business

902-903.qxp

12/16/2013

6:44 PM

Page 903

V-Series Incandescent
Luminaires

1L

Photometric Data

Enclosed and Gasketed
Luminaires V-Series
Lamp: 150W/A23 Clear
Total Bare Lamp Lumens: 2800
All data provided is for 150W incandescent lamp. Use following candela/lumen multipliers
for the other lamp sizes: 100W – 0.61

Example: Zonal lumens
for 150W lamp for
0–40° with guard is 252.

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
1
2
3

4

5

50
30
10

.659
.623
.591

.558
.504
.458

.479
.417
.367

.416
.349
.298

.361
.298
.248

70

50
30
10

.609
.577
.545

.515
.466
.426

.442
.386
.342

.384
.324
.278

.336
.275
.230

50

50
30
10

.515
.491
.469

.434
.397
.364

.372
.328
.293

.321
.274
.238

.282
.234
.197

30

50
30
10

.429
.411
.395

.359
.332
.307

.307
.274
.245

.264
.228
.198

.232
.194
.165

10

50
30
10

.350
.337
.325

.290
.269
.251

.246
.221
.199

.211
.183
.160

.185
.156
.132

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.325
.259
.212

.290
.227
.183

.261
.199
.157

.236
.176
.136

.211
.153
.116

70

50
30
10

.299
.240
.197

.268
.210
.170

.241
.186
.146

.219
.164
.127

.194
.143
.108

50

50
30
10

.252
.205
.169

.226
.178
.145

.203
.158
.125

.185
.140
.109

.165
.122
.092

30

50
30
10

.208
.170
.141

.186
.149
.121

.169
.131
.105

.153
.117
.091

.137
.101
.076

10

50
30
10

.167
.136
.114

.151
.121
.098

.135
.106
.084

.124
.094
.073

.110
.081
.060

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

US: 1-866-764-5454

1L

80

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

903

904-905.qxp

12/16/2013

6:45 PM

Page 904

Cl. I, Div. 2, Groups A, B, C, D
Corrosive
Wet Locations
NEMA 3, 3R, 4, 4X

NDA Corro•Gard™ CorrosionResistant Incandescent
Luminaires

1L

Applications:

Ordering Information:

Corro•Gard™ NDA Series Luminaires made
of Krydon® fiberglass-reinforced polyester
are used to provide incandescent lighting:
• Indoors or outdoors in industrial wet or
dirty locations and where corrosion is a
problem
• In marine applications, above and below
deck, where salt spray corrosion
shortens fixture life
• In food and beverage industries where
frequent wash-downs are necessary
• For walkways, bridges, tunnels, security
lighting, cold storage facilities, garages,
coal handling areas, shipboard,
processing plants, and nuclear
generating plant containment areas

For Pendant Mounting

Features:
• Luminaire is molded Krydon for
excellent corrosion, heat, and impact
resistance
• Accommodates all popular incandescent
lamps up to 300W, PS-25
• Attractive modern design and color
complement other Corro•Gard products
• Weighs only 81/2 lbs. complete with lamp
and globe
• Medium screw base porcelain lamp
socket has a vibration absorbing
mounting bracket
• All joints are gasketed to ensure
watertightness
• Configured glass globe reduces glare
• Corro•Gard reflectors made of Krydon®
reflect light better than porcelainized
steel; do not yellow or discolor with age;
cannot chip, peel, rust or dent

1L

®

Hub
Size

/4"

3

Max.
Lamp
Size

Body
Only
Cat. #

Globe
Only
Cat. #

300W
PS-25
Med.
Base
120V

NDA22 G24

Body
With
Globe
Cat. #

NDA22G

Temperature Performance
Data:
(based on 40°C ambient)
Max.
Lamp Size
300W
Note:

T-Number

Supply
Wire (°C)

T2A

150°C

Fixtures are not marked with T-Number.

Dimensions
In Inches:

Accessories & Parts

Certifications and
Compliances:

Reflectors
(Order separately)

• UL Standard: 1598
• Wet Locations
• Suitable for 40°C ambient temperature

Standard Materials:
• Bodies and reflectors – Krydon®
fiberglass-reinforced polyester material
• Globes – configured heat-resistant glass

Standard Finishes:
• Bodies – natural
• Reflectors – natural, high reflectance
white

Options:
Description
TEFLON® coating on G24 globe for
increased shatter protection

904

www.crouse-hinds.com

Suffix

Globe
Color

Globe
Cat. #

Clear (heat resisting)
Green
Blue
Red
Amber

G24
G25
G26
G27
G28

Guard
Guard
Cat. #

Dome

P21

30° Angle

Replacement Lamp
Receptacles with Strap
Shock Absorbing

Type

Cat. #

Dome
30° Angle

RD725 (RD75)
RA725 (RA75)

S808

US: 1-866-764-5454

Description

Cat. #

Replacement Lamp Receptacles

NV84

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

904-905.qxp

12/16/2013

6:45 PM

Page 905

NDA Corro•Gard™ CorrosionResistant Incandescent
Luminaires

Photometric Data

1L

Lamp: 200W/PS-25
All data provided is for incandescent with 200W/PS-25 lamp. See Multipliers for other wattages and lamp types.

Luminaire With Globe

Luminaire With Globe and
Dome Reflector

Luminaire With Globe and
30° Angle Reflector

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance Room Cavity Ratio
Eff. Ceil. Wall 1
2
3
4
5

Effective Floor Cavity Reflectance 20%
% Reflectance Room Cavity Ratio
Eff. Ceil. Wall 1
2
3
4
5

Total Lumens
2595

50
30
10

.762 .651 .565 .494 .433
.715 .585 .491 .416 .358
.673 .529 .433 .357 .300

80

50
30
10

.809 .703 .615 .541 .481
.773 .647 .550 .470 .408
.742 .601 .499 .416 .354

70

50
30
10

.708 .605 .526 .461 .406
.667 .546 .460 .390 .335
.626 .496 .407 .336 .282

70

50
30
10

.791 .688 .604 .531 .470
.758 .636 .542 .465 .403
.729 .595 .494 .413 .315

50

50
30
10

.608 .519 .452 .395 .292
.576 .473 .399 .339 .250
.547 .432 .356 .295 .248

50

50
30
10

.756 .659 .580 .510 .455
.729 .617 .528 .453 .395
.706 .579 .485 .408 .349

30

50
30
10

.516 .439 .382 .335 .297
.492 .404 .342 .290 .250
.469 .372 .307 .254 .215

30

50
30
10

.726 .634 .558 .492 .439
.705 .599 .514 .442 .385
.684 .566 .477 .402 .344

10

50
30
10

.433 .366 .319 .279 .247
.413 .339 .287 .244 .211
.396 .315 .259 .215 .181

10

50
30
10

.699 .610 .539 .475 .424
.663 .580 .501 .431 .378
.580 .553 .468 .396 .340

0
0
.354 .277 .226 .184 .154
% Reflectance Room Cavity Ratio
Eff. Ceil. Wall 6
7
8
9
10
80

50
30
10

.389 .348 .312 .284 .253
.312 .273 .240 .214 .185
.258 .222 .190 .166 .141

70

50
30
10

50

0
0
.647 .536 .451 .378 .323
% Reflectance Room Cavity Ratio
Eff. Ceil. Wall 6
7
8
9
10
80

50
30
10

.431 .386 .347 .317 .277
.360 .317 .280 .250 .211
.309 .269 .231 .204 .169

.363 .324 .291 .266 .236
.293 .256 .226 .201 .175
.242 .208 .179 .157 .133

70

50
30
10

.423 .380 .342 .312 .272
.356 .312 .277 .247 .211
.305 .265 .231 .204 .169

50
30
10

.312 .280 .252 .230 .205
.256 .223 .198 .177 .153
.213 .183 .158 .139 .117

50

50
30
10

.408 .368 .331 .302 .265
.348 .305 .272 .243 .207
.303 .263 .229 .202 .167

30

50
30
10

.266 .238 .216 .197 .175
.220 .193 .170 .152 .131
.185 .158 .137 .121 .100

30

50
30
10

.396 .355 .321 .294 .257
.342 .301 .266 .238 .203
.300 .260 .227 .201 .165

10

50
30
10

.223 .201 .180 .166 .147
.185 .163 .144 .129 .110
.156 .135 .116 .102 .084

10

50
30
10

.383 .346 .311 .285 .250
.334 .295 .262 .235 .200
.297 .258 .225 .199 .163

0

0

.132 .112 .096 .084 .068

0

0

.281 .243 .210 .184 .150

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

80.6

Multipliers for Other Lamps
Photometric data was developed using a
200 watt/PS-25 inside frosted
incandescent lamp (3,220 lumens). For
other incandescent watts/lamp size, use
the following conversion factors
(multipliers):
Lamp Lamp
Conversion
Watts Size
Lumens Factor
100
A-19
1750
.54
100
A-21
1690
.52
150
150

A-21
PS-25

2880
2680

.89
.83

200

A-23

4010

1.25

300

PS-25

6360

1.98

Example: Zonal lumens for 200W/PS-25
luminaire with globe and dome reflector
for 30–40° is 389. Zonal lumens for
100W/A-21 luminaire with globe and dome
reflector for 30–40° is 389 × .52 = 202.

Copyright© 2013 Eaton’s Crouse-Hinds Business

905

1L

80

Eff. %

906-907.qxp

12/16/2013

6:46 PM

Page 906

1L

1L

906

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

906-907.qxp

12/16/2013

6:46 PM

Page 907

2L

LED Luminaires
Industrial and Hazardous Areas

Description

Page No.

Application/Selection

see pages 908–909

Industrial and Hazardous Area LED Luminaires
EV LED Series

see pages 910–913

Hazard•Gard EVLL Series

see pages 914–918

Hazard•Gard® LPL Series

see pages 919–921

®

LL48 Series

see pages 922–923

Champ® VMV LED Series

see pages 924–928

Champ® FMV LED Series

see pages 929–932

Vaporgard™ LED Series

see pages 933–936

N2LPS Light-Pak™ Emergency Lighting System

see pages 937–939

Ex-Lite Series LED Exit Signs

see page 940

CCH UX Series LED Exit Signs

see page 941

Champ® Pro PVM Series

see pages 943–946

Champ® Pro PFM Series

see pages 947–948

Champ® Pro PFM25L and 50L Series

see pages 949–951

Vaporgard™ Pro P2L Series

see pages 952–954

Industrial High Bay LED Series

see page 955

Endure™ LED Series

see pages 956–957

LED Obstruction Lights and Visual Signals

See Obstruction
Lighting Guide

2L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

907

908-909.qxp

12/16/2013

6:48 PM

Page 908

LED Luminaires

2L

Application and Selection

Applications:

Considerations for
Selection:
Environmental:
• What are the hazardous areas
classifications (NEC/CEC) of the
locations in which the luminaires will be
installed?
• Must luminaires be suitable for use in
marine, hosedown, corrosive
applications?
Lighting levels required:
• What wattage luminaire(s) will provide
the desired light level?
Watts
HPS, MH &
Pulse Start MH Lamps
26 Watts; 30 Watts; 36
Watts

Hazardous Area & Other
Enviromental Suitabilities
NEC, CEC, IEC
NEC & CEC
Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E, F, G
Marine and Wet Locations, Type 4X, IP66
NEC
Cl. III, Simultaneous Presence

Series
EV LED

Application
General Illumination

Hazard•Gard EVLL LED

General Illumination

80 Watts; 100 Watts; 130
Watts; 151 Watts; 175
Watts

NEC & CEC
Cl. I, Div. 1, Groups B, C, D
Cl. I, Zone 1, Groups IIB + H2, IIB, IIA
Cl. II, Groups E, F, G
Cl. III, Simultaneous Presence

Hazard•Gard LPL LED

General Illumination

60 Watts; 85 Watts; 100
Watts; 125 Watts; 150
Watts

IEC
Zones 1 and 2 (Ex-gas)
Zones 21 and 22 (Ex-dust)

LL48 Linear LED

General Illumination

56 Watts

NEC
Cl. I, Div. 2, Groups A, B, C, D
NEMA 4X, IP66
Marine and Wet Locations

Champ® VMV LED

General Illumination

41 Watts; 67 Watts; 94
Watts; 114 Watts; 118
Watts

NEC & CEC
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, nA nR
Cl. II, Groups E, F, G
Cl. III
Simultaneous Presence
Wet Locations, Type 4X, IP66

Champ® FMV LED

Outdoor/Indoor Flood
Illumination

64 Watts; 89 Watts; 121
Watts; 149 Watts; 179
Watts

NEC & CEC
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III
Simultaneous Presence
Wet Locations, Type 4X, IP66

Vaporgard™ LED

Targeted Illumination

22 Watts

NEC & CEC
Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 1, Groups F, G
NEMA 4X

N2LPS Light-Pak™

Emergency Illumination

Input: 9 Watts max.
Lamp: 3 Watts

NEC & CEC
Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 2
Cl. II, Div. 1
Marine Wet Locations Suitability, Type 4X

2L

2L

Luminaires included in this section are
designed for use:
• In manufacturing plants; heavy industrial,
chemical, petrochemical, or
pharmaceutical facilities; platforms;
loading docks; tunnels

908

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

908-909.qxp

12/16/2013

6:48 PM

Page 909

2L

LED Luminaires
Application and Selection

Application
Emergency Illumination

CCH UX

Emergency Illumination

3.2 Watts

NEC
Cl. I, Div. 2, Groups A, B, C, D
IP65, IP66
Wet Locations
NEMA 4X

Champ® Pro PVM

General High Bay/Low Bay
Illumination

41 Watts; 67 Watts; 94
Watts; 114 Watts; 118
Watts

NEC & CEC
UL1598
UL1598A
cUL
NEMA 4X
IP66

Champ® Pro PFM

Outdoor/Indoor Flood
Illumination

64 Watts; 89 Watts; 121
Watts; 149 Watts; 179
Watts

NEC & CEC
UL1598
UL1598A
cUL
NEMA 4X
IP66

Champ® Pro PFM 25L and
50L

Outdoor/Indoor Flood
Illumination

263 Watts; 531 Watts

NEC & CEC
UL1598
UL1598A
cUL
NEMA 4X
IP66

Vaporgard™ Pro P2L

Targeted Illumination

22 Watts

NEC & CEC
UL1598
UL1598A
cUL
NEMA 4X
IP66

Industrial High Bay LED

General Illumination

141 Watts (at 120 VAC);
138 Watts (at 277 VAC)

Meets UL1598 and cUL construction
requirements

Endure™ LED Wall Pack

General Illumination

27 Watts; 51 Watts

NEC & CEC
UL1598
cUL
IP66

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Hazardous Area & Other
Enviromental Suitabilities
NEC, CEC, IEC
NEC & CEC
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, AEx em ib IIC
Cl. II, Div. 2, Groups F, G

Copyright© 2013 Eaton’s Crouse-Hinds Business

2L

Series
Ex-Lite

Watts
HPS, MH &
Pulse Start MH Lamps
6 Watts

909

910-911.qxp

12/16/2013

2L

6:50 PM

Page 910

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E, F, G
Cl. III, Simultaneous
Presence

EV LED Series Explosionproof
LED Luminaires
Factory-sealed
Improve safety, reliability
and energy efficiency

The enhanced EV LED product offering
provides the same durability and reliability
of a traditional EV incandescent or HID
fixture, coupled with the low cost of
ownership and energy efficiency of Eaton's
Crouse-Hinds LED technology. Highperformance LEDs and a solid state
electronic driver provide light where you
need it, at a fraction of the operating costs
of HID and incandescent lighting
technologies.

EV LED Benefits:

EV LED Series Luminaires are designed to
provide durable and energy-efficient
lighting in a variety of applications.
Incandescent and HID general illumination
models are available, along with a wildlife
friendly model and optional DC input
voltage.

• Easy installation – compact modular
fixture attaches onto existing Champ
mounting module
• Energy-efficient – up to 85% reduction
in energy used
• Provides up to 50,000 hours rated life –
eliminates need for frequent lamp
replacement
• Contains no mercury or other hazardous
substances

Applications:

2L

• Two lumen outputs for replacement of
existing HID and incandescent luminaires
• Locations requiring continuous and
consistent light levels in extreme ambient
temperatures
• Areas requiring frequent on-and-off of
lights
• Where flammable vapors, gases,
ignitable dusts, fibers or flyings are
present; indoors or outdoors
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist
• Type 4X, marine, wet locations and
hose-down environments
• Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; platforms;
loading docks; tunnels; outdoor wall and
stanchion mounted general area lighting

Certifications &
Compliances:

Enhance safety and productivity
• Instant illumination and re-strike
• Better visibility with crisp, white light
• T6 temperature rating – safely operate in
the most hazardous environments
• Cold temperature operation / no
warm-up required

Reduce operation and
maintenance costs

Reliable performance in any
environment
• Shock- and vibration-resistant
solid-state luminaires have no filaments
or glass components that could
break – greatly reduces the risk of
premature failure
• Operating ambient -30°C to 55°C (AC),
-30°C to 40°C (DC)
• Dark sky compliant

Standard Materials:
• Body, mounting modules and guard –
copper-free aluminum with Corro-free™
epoxy powder coat
• Globe – heat and impact-resistant glass
• Gaskets – silicone
• External hardware – stainless steel

Electrical Ratings:

NEC & CEC
•
•
•
•
•
•
•

Class I, Division 1, Groups C, D
T6 temperature rating at 55°C
Class I, Zone 1 & 2, Group IIB
Class II, Groups E, F, G
Marine and wet locations, Type 4X, IP66
UL Listed
cUL Listed (certified by UL to CSA
standards)

NEC
• Class III, simultaneous presence

UL Standards
• 844 Electric Fixture Hangers for
Hazardous Locations
• 1598 Luminaire
• 1598A Luminaire for Installation on
Marine Vessels

CSA Standards
• C22.2 No. 137

910

www.crouse-hinds.com

UL Listed
cUL Listed (certified by
UL to CSA standards)
T6 temperature rating at 55°C
Marine and wet locations
Type 4X, IP66

US: 1-866-764-5454

Voltage Range
Frequency
Input Power
Input Amps (Max.)
Power Factor

C201

C701

A201

C201/DC

100-277V
50 / 60 Hz
30W
0.30A
0.98

100-277V
50 / 60 Hz
36W
0.36A
0.99

100-277V
50 / 60 Hz
36W
0.36A
0.98

10-30 VDC
50 / 60 Hz
26W
2.8A
0.99

LED System:
• High brightness light emitting diode
(LED) arrays
• Color temperature: 3000K (CRI 82) and
5600K (CRI 65) options available
• Amber color available for wildlife friendly
applications
• Advanced heat sink design ensures
LED does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions
• LM-79 and LM-80 reports available

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

910-911.qxp

12/16/2013

6:50 PM

Page 911

EV LED Series Explosionproof
LED Luminaires
Factory-sealed
Improve safety, reliability and energy efficiency

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E, F, G
Cl. III, Simultaneous
Presence

UL Listed
cUL Listed (certified by UL to
CSA standards)
T6 temperature rating at 55°C
Marine and wet locations
Type 4X, IP66

2L

Ordering Information:
Cool Color Temperature

Mounting Style

Warm Color Temperature
W201

Wildlife Friendly

C201

C701

Luminaire Only

EVLEDC201

EVLEDC701

EVLEDW201

EVLEDW701

W701

EVLEDA201

A201

3

/4" Pendant

EVLEDA2C201

EVLEDA2C701

EVLEDA2W201

EVLEDA2W701

EVLEDA2A201

1" Pendant

EVLEDA3C201

EVLEDA3C701

EVLEDA3W201

EVLEDA3W701

EVLEDA3A201

3

/4" Ceiling Mount Thru Feed

EVLEDCX2C201

EVLEDCX2C701

EVLEDCX2W201

EVLEDCX2W701

EVLEDCX2A201

1" Ceiling Mount Thru Feed

EVLEDCX3C201

EVLEDCX3C701

EVLEDCX3W201

EVLEDCX3W701

EVLEDCX3A201

3

/4" Wall Mount Thru Feed

EVLEDBX2C201

EVLEDBX2C701

EVLEDBX2W201

EVLEDBX2W701

EVLEDBX2A201

1" Wall Mount Thru Feed

EVLEDBX3C201

EVLEDBX3C701

EVLEDBX3W201

EVLEDBX3W701

EVLEDBX3A201

3

/4" Bulkhead Mount

EVLEDBH2C201

EVLEDBH2C701

EVLEDBH2W201

EVLEDBH2W701

EVLEDBH2A201

11/4" Stanchion

EVLEDJ4C201

EVLEDJ4C701

EVLEDJ4W201

EVLEDJ4W701

EVLEDJ4A201

To order a fixture without a guard, remove ‘1’ from the end of the catalog number (Example: EVLEDAC20 for 3/4" Pendant, No Guard).
To order a fixture with 10-30VDC Input Voltage (available on 20 Series Only), add /DC to the end of the catalog number
(Example: EVLEDAC201/DC).
To order a fixture with colored inserts (available on C20 Series Only), add a "G" (for green) or "R" (for red) to the end of the catalog number
(Example: EVLEDAC201G).

Family Tree:
Stanchion
EVMJ4 1-1/4” HUB4

Ceiling
EV22 3/4” HUB4
EV33 1” HUB4

Pendant
EVMP2 3/4” HUB4
EVMP3 1” HUB4

Wall
EV22 & EV87 3/4” HUB4
EV33 & EV87 1” HUB4

Bulkhead
EVU 3/4” HUB4

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

2L

EVLED with Guard
(Luminaire Only)

911

912-913.qxp

12/16/2013

6:51 PM

Page 912

2L EV LED Series Explosionproof
LED Luminaires
Factory-sealed
Improve safety, reliability and energy efficiency

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E, F, G
Cl. III, Simultaneous
Presence

UL Listed
cUL Listed (certified by UL to
CSA standards)
T6 temperature rating at 55°C
Marine and wet locations
Type 4X, IP66

Photometrics:

POLAR PLOT (EVLEDC701)

DISTANCE TO MOUNTING HEIGHT
Isofootcandle chart shows illuminance in
footcandles at ground level

(EVLEDC701)

ISOFOOTCANDLE CHART

2L

Footcandle Values for Isofootcandle Lines

ZONE (DEGREES)

LUMENS

% OF LUMINAIRE

0-30

451

20.1%

0-40

688

30.6%

0-60

1688

75.1%

0-90

2196

A

B

C

D

E

F

Mtg.
Hgt.

A

B

C

D

E

F

10’

4.00

2.00

1.00

0.50

0.25

0.12

97.7%

12’

2.78

1.39

0.69

0.35

0.17

0.09

16’

1.56

0.78

0.39

0.20

0.10

0.05

20’

1.00

0.50

0.25

0.12

0.06

0.03

25’

0.64

0.32

0.16

0.08

0.04

0.02

90-180

51

2.3%

0-180

2248

100.0%

LUMEN OUTPUT FOR OTHER EV LED LUMINAIRES

System
Watts

Lumens

C201

30W

1670

A201

36W

1195

C201/DC

26W

1493

Luminaire
Series

912

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

912-913.qxp

12/16/2013

6:51 PM

Page 913

EV LED Series Explosionproof
LED Luminaires
Factory-sealed
Improve safety, reliability and energy efficiency

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E, F, G
Cl. III, Simultaneous
Presence

UL Listed
cUL Listed (certified by UL to
CSA standards)
T6 temperature rating at 55°C
Marine and wet locations
Type 4X, IP66

2L

Dimensions (inches):
Pendant Mount

Ceiling Mount

)

)

Stanchion Mount

6-3/4
4

13-1/4
5/16

4

12

1-1/4
12-3/4
13-1/2

1
13
13-3/4

12-3/4

1-1/4
conduit
25°

7-1/4

7-1/4

Bulkhead

Wall Mount

)

16-1/16
16-13/16

9-1/4

1-5/16

12-9/16
9-7/16

6-3/4
4

4

4
13/32

13/16

2L

5/16

16-1/8
15-3/8

Net Weight (lbs.):
EV LED with Guard
Add Mounting Modules:
Pendant
Ceiling
Wall
Bulkhead
Stanchion

11 lbs.
1.0
2.0
4.5
2.2
2.5

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

lbs.
lbs.
lbs.
lbs.
lbs.

Copyright© 2013 Eaton’s Crouse-Hinds Business

913

914-915.qxp

12/16/2013

2L

6:53 PM

Page 914

Cl. I, Div. 1, Groups B, C, D
Cl. I, Zone 1, Groups IIB +
H2, IIB, IIA
Cl. II, Groups E, F, G
Cl. III

Hazard•Gard® EVLL Series
Explosionproof LED Luminaires
Class I, Division 1 factory-sealed LED
luminaire for general illumination

The EVLL LED Family

EVLL LED Benefits:

Hazard•Gard® EVLL Series LED Luminaires
are designed to provide full-spectrum,
crisp, white light. Five versions of the EVLL
LED are available, providing ideal solutions
for a wide range of applications.

Industry best for ease of
installation

Typical
Energy
Savings

Model

Equivalent HID
Luminaire

EVLL5L
EVLL7L
EVLL9L
EVLL11L
EVLL13L

100W-150W MH
150W-175W HPS/MH
Up to
175W-250W MH
62%
250W-400W HPS/MH
400W HPS/MH PS

Applications:

2L

• Five lumen outputs for replacement of
existing HID luminaires
• Locations requiring continuous and
consistent light levels in extreme ambient
temperatures
• Areas requiring frequent on-and-off of
lights
• Where flammable vapors, gases,
ignitable dusts, fibers or flyings are
present; indoors or outdoors
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist
• NEMA 4X, marine, wet locations, and
hose-down environments
• Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; platforms;
loading docks; tunnels; outdoor wall and
stanchion mounted general area lighting

UL Listed & CSA Certified
IEC / ATEX (Pending)
Simultaneous Presence
Marine & Wet Locations
NEMA 4X, IP66

• Quick-connect design – install and wire the
mounting module, then simply screw in the
luminaire
• Factory-sealed – no external sealing fittings
required in Groups B, C, and D
• Adapter available for connection to existing
Hazard•Gard® EVI, EVLP, and EVM modules

Reduce operation and
maintenance costs
• Energy-efficient – up to 62% reduction in
energy used versus equivalent HID fixtures
• 60,000 hours rated life – eliminates need for
frequent lamp replacement

Reliable performance in any
environment
• Shock- and vibration-resistant solid-state
luminaires have no filaments or glass
components that could break – greatly
reduces the risk of premature failure
• T5 temperature rating
• Operating ambient -25°C to 65°C

Certifications and
Compliances:
NEC and CEC
• Class I, Division 1, Groups B, C, D
• Class I, Zone 1, Groups IIB + H2, IIB, IIA
• Class II, Groups E, F, G
• Class III, Simultaneous Presence
UL Standards
• UL844 Electric Fixture Hangers for
Hazardous Locations
• UL1598 Luminaires
• UL1598A Luminaire for Installation on
Marine Vessels
CSA Standard
• CSA C22.2 No. 137
Environmental Ratings
• NEMA 4X
• IP66
• Marine and Wet Locations
IEC and ATEX Certifications and Protection
(Pending)
• Ex II 2G Ex d IIC (Zone 1, 2) (Pending)
• Ex II 2D Ex tD A21 IP66 (Zone 21, 22)
(Pending)

Standard Materials:
• Body and mounting modules – copperfree aluminum with Corro-free™ epoxy
powder coat
• Lens – shatter-resistant, explosionproof
glass
• Gaskets – silicone
• Guard – stainless steel
• External hardware – stainless steel
• Factory-sealed*
*Refer to Installation and Maintenance Sheet for external
seal requirements.

LED System:
• High brightness light emitting diode
(LED) arrays
• Color temperature: 3000K (CRI 82) and
5600K (CRI 65) options available
• Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions
• LM-79 and LM-80 reports available

Electrical Ratings:
Model

Voltage

Input Amps (Max.)

Power Factor

Input Power

Lumen Output

EVLL5L

100-277VAC, 50 / 60 Hz
108-250VDC

0.46-0.82
0.38-0.89

0.99%
1

80W

5625

EVLL7L

100-277VAC, 50 / 60 Hz
108-250VDC

0.51-1.11
0.42-1.15

0.99%
1

100W

6750

EVLL9L

100-277VAC, 50 / 60 Hz
108-250VDC

0.61-1.19
0.56-1.30

0.99%
1

130W

9000

EVLL11L

100-277VAC, 50 / 60 Hz
108-250VDC

0.76-1.56
0.73-1.71

0.99%
1

151W

10500

EVLL13L

100-277VAC, 50 / 60 Hz
108-250VDC

0.78-1.58
0.75-1.73

0.99%
1

175W

13500

914

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

914-915.qxp

12/16/2013

6:53 PM

Page 915

Hazard•Gard® EVLL Series
Explosionproof LED Luminaires
Class I, Division 1 factory-sealed LED
luminaire for general illumination

Cl. I, Div. 1, Groups B, C, D
Cl. I, Zone 1, Groups IIB +
H2, IIB, IIA
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IEC / ATEX (Pending)
Simultaneous Presence
Marine & Wet Locations
NEMA 4X, IP66

2L

Installation and replacement made simple
Modular design - This contractor-friendly design is
ideal for both new construction applications and retrofit.
These luminaires use the same mounting modules as
existing Hazard•Gard® Series luminaires. The quickconnect design facilitates installation - install and wire the
mounting module, then screw in your luminaire. Two start Acme threads
ease and reduce installation time.

High efficiency and lumen output
Driver module assembly - High efficiency LED drivers are designed to
provide reliable operation in even the harshest environments. Various AC
and DC input voltage options are available to suit virtually any drive
requirement.

Safe, reliable heat transfer
Heat sink - Enhanced heat sink design
provides safe and effective heat transfer
from the LED assembly to the outside
environment, ensuring low LED junction
temperature, reliability and sustained
lumen performance.

2L

NEMA 4X rated
LED housing assembly - The LED housing is constructed of
durable die cast aluminum, providing an efficient thermal path to
the heat sink assembly. The impact-resistant lens is sealed from the
outside environment and provides ingress protection against water
and dust. Multi-die LED arrays are used to provide energy-efficient,
long-life white light.

www.crouse-hinds.com

Optional color temperatures
Warm (available on 5L through 11L models
only) and cool white color temperatures
available.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

915

916-917.qxp

12/16/2013

2L

6:54 PM

Page 916

Hazard•Gard® EVLL Series
Explosionproof LED Luminaires
Class I, Division 1 factory-sealed LED
luminaire for general illumination

Cl. I, Div. 1, Groups B, C, D
Cl. I, Zone 1, Groups IIB +
H2, IIB, IIA
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IEC / ATEX (Pending)
Simultaneous Presence
Marine & Wet Locations
NEMA 4X, IP66

Catalog Numbering System:
SERIES

LAMP
OUTPUT

LED
COLOR

MOUNTING
MODULE

HUB SIZE

GUARD

VOLTAGE

EVLL

5L

C

A

2

0

/UNV1

SERIES
EVLL

SUFFIXES

Explosionproof Vaportight Low Profile LED Luminaire

LAMP OUTPUT
5L
5,625 Lumen Output
7L
6,750 Lumen Output
9L
9,000 Lumen Output
11L
10,500 Lumen Output
13L
13,500 Lumen Output
LED COLOR
C
Cool (5600K nominal)
W
Warm (3000K nominal) (available on 5L through 11L models only)

2L

MOUNTING MODULE
A
Pendant EVSP
BX
Wall Bracket EVSW
CX
Ceiling Mount EVSC

916

J
M
Blank

Stanchion EVSJ
Mounting Module Adapter EVSA (See Note #1)
No Mounting Module Supplied

HUB SIZE
2
3
5
25
32
Blank

⁄4” NPT (Pendant, Ceiling, and Wall Only)
1” NPT (Pendant, Ceiling, and Wall Only)
1 1⁄2” NPT (Stanchion Only)
25 mm (Pendant, Ceiling, and Wall Only)
32 mm (Pendant, Ceiling, and Wall Only)
Leave Blank for Mounting Module Adapter and No Mounting Module

GUARD
0
1

No Guard
Stainless Steel

3

Notes:

VOLTAGE (See Note #2)
/UNV1
120VAC to 277VAC 50/60 Hz, 108VDC to 250VDC

1. EVSA Adapter for use with existing Eaton’s
Crouse-Hinds EVI, EVLP, and EVM mounting
modules.

SUFFIXES
S812
Trunnion Mount

2. Accessory kit EVLL347/480 K1 (step down
transformer in separate enclosure) is
available for 347V and 480V 60 Hz
applications.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

916-917.qxp

12/16/2013

6:54 PM

Page 917

Cl. I, Div. 1, Groups B, C, D
Cl. I, Zone 1, Groups IIB +
H2, IIB, IIA
Cl. II, Groups E, F, G
Cl. III

Hazard•Gard® EVLL Series
Explosionproof LED Luminaires
Class I, Division 1 factory-sealed LED
luminaire for general illumination

UL Listed & CSA Certified
IEC / ATEX (Pending)
Simultaneous Presence
Marine & Wet Locations
NEMA 4X, IP66

2L

Dimensions (In Inches):
Ceiling Mount

Pendant Mount

Wall Mount

Stanchion Mount

[241.5]
9.51
[80.2]
3.16

[104] [91.3]
4.09 3.59

25°

[366.2] [391.6]
14.42 15.42

[334.5]
13.17

[342.4] [367.8]
13.48 14.48

[353]
13.90
[378.4]
14.90

[404.8]
Ø 16
[414.4]
Ø 16.32

[414.4]
Ø 16.32

[345.2]
13.59

[341.9]
13.46
[407.7]
16.05

[454.6]
17.90
[459.5]
18.09

[407.6]
Ø 16.05

Ambient Temperature:

Weights:
Model

Lbs.

EVLL5L
EVLL7L
EVLL9L
EVLL11L
EVLL13L
Add Mounting Modules:
Pendant
Ceiling
Stanchion
Wall
Adapter

51.76
51.81
52.38
53.00
53.00
2.00
3.50
3.00
5.50
2.00

Max. Ambient
Temp. ºC

Cl. I, Div. 1

Cl. II, Div. 1 & 2 /
Simu. Presence

Cl. I, Zone 1

EVLL5L

40
55
65

T6
T6
T5

T5
T5
T5

Pending
Pending
Pending

EVLL7L

40
55
65

T6
T6
T5

T5
T5
T5

Pending
Pending
Pending

EVLL9L

40
55
65

T6
T6
T5

T5
T5
T5

Pending
Pending
Pending

EVLL11L

40
55

T6
T6

T5
T5

Pending
Pending

EVLL13L

40
55

T6
T6

T5
T5

Pending
Pending

Model

Family Tree:
EVMJ4

EV22
EV33

EVMP2
EVMP3

EVJ2

2L

EV22
EV33

EV87

EVSJ5

EVSA
EVSC2 EVSC25
EVSC3 EVSC32

EVSW2
EVSW3
EVSW25
EVSW32

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

EVSP2
EVSP3
EVSP25
EVSP32

Copyright© 2013 Eaton’s Crouse-Hinds Business

917

918-919.qxp

2L

12/16/2013

6:56 PM

Page 918

Hazard•Gard® EVLL Series
Explosionproof LED Luminaires
Class I, Division 1 factory-sealed LED
luminaire for general illumination

Cl. I, Div. 1, Groups B, C, D
Cl. I, Zone 1, Groups IIB +
H2, IIB, IIA
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IEC / ATEX (Pending)
Simultaneous Presence
Marine & Wet Locations
NEMA 4X, IP66

Photometric Data:
POLAR PLOT CANDELA
(EVLL13LCA20/UNV1)

DISTANCE TO MOUNTING HEIGHT
Isofootcandle chart shows illuminance in
footcandles at ground level

(EVLL13LCA20/UNV1)
3
2
1
0
-1
-2
-3
-3

-2

-1

0

1

2

3

ISOFOOTCANDLE CHART
Footcandle Values for Isofootcandle Lines

2L

A

B

C

D

E

F

ZONE (DEGREES)

LUMENS

% OF LUMINAIRE

Mtg.
Hgt.

A

B

C

D

E

F

0-30

4221

31.7%

12’

34.72

13.89

6.94

3.47

1.39

0.69

0-40

6923

52.1%

16’

19.53

7.81

3.91

1.95

0.78

0.39

0-60

11630

87.5%

20’

12.50

5.00

2.50

1.25

0.50

0.25

0-90

13500

100.0%

25’

8.00

3.20

1.60

0.80

0.32

0.16

90-180

0

0%

0-180

13500

100.0%

LUMEN OUTPUT FOR OTHER EVLL LED LUMINAIRES

Luminaire
Series
EVLL5L
EVLL7L
EVLL9L
EVLL11L
EVLL13L

918

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

System
Watts
80W
100W
130W
151W
175W

Lumens
5625
6750
9000
10500
13500

918-919.qxp

12/16/2013

6:56 PM

Page 919

Hazard•Gard® LPL Series
Explosionproof LED Luminaires

2L

Zones 1 & 2 (Ex-Gas)
IECEx / ATEX
Zones 21 & 22 (Ex-Dust) IP66

Zone 1 high power LED pendant for
general illumination
The LPL LED Family
The LPL LED Luminaire is available in five different versions,
providing ideal solutions for a wide range of applications.

Model

Equivalent HID
Luminaire

Typical Energy
Savings

LPL04-C60-60W
LPL04-C60-85W
LPL04-C60-100W
LPL06-C60-125W
LPL06-C60-150W

70W-100W MH
150W MH
175W MH
175W-250W MH
250W MH

40%

Applications:
• Zone 1/Zone 2 Ex-Gas and Zone 21/Zone 22 Ex-Dust hazardous
areas
• Heavy industrial, chemical, petrochemical, or pharmaceutical
facilities
• Offshore platforms
• Shipyards
• Electric power
• Loading docks
• Wastewater treatment plants
• Paper mills

LPL LED Benefits:
Robust construction
• Copper-free aluminum housing
• Tempered and impact-resistant glass globe, heat- and corrosionproof
• Explosionproof design suitable for Zones 1 and 2 (Ex-Gas) and
Zones 21 and 22 (Ex-Dust) hazardous areas
• Standard U-shape mounting bracket for ceiling and wall mount;
pole mount accessories are available (order separately)

Reduce operation and maintenance costs

Reliable performance in any environment
• High quality LED application, shock- and vibration-resistant
• T6 temperature rating
• Operating ambient -35°C to +50°C (60W-100W models); -35°C to
+40°C (125W-150W models)
• Warm white color temperature (3300K) is available for special
environments, such as fog or smoke
• Lead-free and environmentally friendly
• Insulation class I

• Zones 1 and 2 (Ex-Gas)
• Zones 21 and 22 (Ex-Dust)
• Marking to 94/9/EC:
Ex II 2 GD Ex d e IIC T6 Gb
Ex II 2 GD Ex tb IIIC T80°C Db IP66
• EC-type Exam Certification: DNV 11 ATEX 06805X
• IECEx - Certificate of Conformity: IECEx-CM 12.0007X
• IP66

Standard Materials:

2L

• Energy-efficient – 40% reduction in energy used versus equivalent
metal halide HID luminaires
• 50,000 hours rated life – eliminates need for frequent lamp
replacement

Certifications and Compliances:

• Housing – copper-free aluminum
• Globe – tempered and impact-resistant glass, heat- and corrosionproof

LED System:
• BridgeLux 10W-30W high power LED array
• Color temperature: 6000K cool white (standard); 3300K warm
white (optional, for special order)
• CRI ≥ 65

Electrical Ratings:
Model

Voltage

LPL04-C60-60W
LPL04-C60-85W
LPL04-C60-100W
LPL06-C60-125W
LPL06-C60-150W

100-277VAC
100-277VAC
100-277VAC
100-277VAC
100-277VAC

50
50
50
50
50

/
/
/
/
/

60
60
60
60
60

Hz
Hz
Hz
Hz
Hz

Power Factor

Input Power

>
>
>
>
>

60W
85W
100W
125W
150W

0.9
0.9
0.9
0.9
0.9

Specifications:
Light Angle

Cable Entry

Terminal

Permissible Ambient Temperature

120°

2 x M25 x 1.5, 1 entry plugged

3 pole, 0.5mm2 to 6mm2 for solid wire

-35°C to +50°C
-35°C to +40°C

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

60W, 85W, 100W
125W, 150W

Copyright© 2013 Eaton’s Crouse-Hinds Business

919

920-921.qxp

12/16/2013

2L

7:40 PM

Page 920

Hazard•Gard® LPL Series
Explosionproof LED Luminaires

Zones 1 & 2 (Ex-Gas)
IECEx / ATEX
Zones 21 & 22 (Ex-Dust) IP66

Zone 1 high power LED pendant for
general illumination

Robust construction

Variety of mounting options

This corrosion-proof fixture offers high quality,
shock- and vibration-resistant LEDs, copper-free
aluminum housing, and an impact-resistant glass
globe.

U-shape mounting bracket for ceiling and wall
mount is standard. Pole mounting accessories
are available and can be purchased
separately.

2L

Perfect temperature and optical performance for a
wide variety of applications
With a T-rating of T6, the 60W to 100W models offer a
permissible temperature range of -35°C to +50°C, while the
125W and 150W models have an ambient temperature of
-35°C to +40°C. Warm white (3300K) color temperature is
also available for special environments, such as fog or smoke.

Excellent thermal management
Provides over 50,000 hours of life under
appropriate ambient temperature.

Ordering Information - Cool White Color Temperature:
Ordering Code

Product Type

Wattage

Color Temperature

Ambient Temperature

CCL1090001A

LPL04-C60-60W

60W

6000K

-35°C - +50°C

CCL1090002A

LPL04-C60-85W

85W

6000K

-35°C - +50°C

CCL1090003A

LPL04-C60-100W

100W

6000K

-35°C - +50°C

CCL1090004A

LPL06-C60-125W

125W

6000K

-35°C - +40°C

CCL1090005A

LPL06-C60-150W

150W

6000K

-35°C - +40°C

Ordering Information - Warm White Color Temperature:
Ordering Code

Product Type

Wattage

Color Temperature

Ambient Temperature

CCL1090006

LPL04-W33-60W

60W

3300K

-35°C - +50°C

CCL1090007

LPL04-W33-80W

80W

3300K

-35°C - +50°C

CCL1090008

LPL04-W33-90W

90W

3300K

-35°C - +50°C

CCL1090009

LPL06-W33-110W

110W

3300K

-35°C - +40°C

CCL1090010

LPL06-W33-130W

130W

3300K

-35°C - +40°C

920

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

920-921.qxp

12/16/2013

7:40 PM

Page 921

Hazard•Gard® LPL Series
Explosionproof LED Luminaires

Zones 1 & 2 (Ex-Gas)
IECEx / ATEX
Zones 21 & 22 (Ex-Dust) IP66

2L

Zone 1 high power LED pendant for
general illumination
Dimensions:

Weights:
R25
R15

230
30˚
250

230

240.2

Model

Kg.

LPL04-C60-60W
LPL04-C60-85W
LPL04-C60-100W
LPL06-C60-125W
LPL06-C60-150W

17.0
17.0
17.0
17.0
17.0

70
40

45

160
277

Ø302.9

Ø17

2-Ø13

30˚

Wall Mount

Ceiling Mount

Note: As shown in drawing, U-shape bracket set includes angle locator, to install the bracket
horizontally (wall mount) or vertically (ceiling mount) to adjust the aim light to 30˚ past vertical.

Pole Mounting Accessories (Order Separately):
Ordering Code
CCL1076003

Product Type
Please refer to below drawing for pole mounting accessories
335.5
60

500
438
20˚

2L

Note:

1. Scope of supply excludes pole mounting accessories, need to purchase separately.
2. As shown in drawing, pole mounting bracket set includes angle locator. To install the bracket vertically, adjust the aim light to 20˚ past vertical.

Polar Curve:
Standard 6000K,
60WCurve
Light
Polar
LPL04-C60-60W

Standard 6000K, 85W Light
LPL04-C60-85W

-/+180
-150

-150

150

-120

0

90

0

-90

60

900

1500
0

0

-90

90

30

-60

800

-30

150 0
0

-60

60

900
30

Standard 6000K, 125W Light
LPL06-C60-125W

: cd
C0/180
C30/210
C60/240
C90/270

-30

120

0

-60

90

120

0

-90

500

800

1000
60

1600
2000
0

: cd
C0/180
C30/210
C60/240
C90/270

150

-120

400

1200
-30

30

-/+180
-150

150

-120

-90

2000
0

Standard 6000K, 150W Light
LPL04-C60-150W

-/+180
-150

60

1200
1600

120 0

: cd
C0/180
C30/210
C60/240
C90/270

90

400

600

1200
-30

120

300

600

150

-120

120

300
-60

-/+180
-150

150

-120

120

-90

Standard 6000K, 100W Light
LPL04-C60-100W

-/+180

30

: cd
C0/180
C30/210
C60/240
C90/270

www.crouse-hinds.com

-60

90

60

1500
2000
-30

2500
0

US: 1-866-764-5454

30

: cd
C0/180
C30/210
C60/240
C90/270

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

921

922-923.qxp

2L

12/16/2013

7:01 PM

Page 922

Cl. I, Div. 2, Groups A, B, C, D NEMA 4X; IP66
Marine and Wet Locations
UL Listed
CSA Certified

LL48 Linear
LED Luminaires
For heavy industrial applications

The LL48 Linear LED Luminaire allows for the replacement of
existing harsh and hazardous industrial fluorescent fixtures and
provides an energy-efficient proven light source for use in
applications where reliability is critical.

A

Luminaire Model:
Model

Equivalent Light Output

Energy Savings

LL48

2 x 58W fluorescent light

50%

B

Applications:

C

• Used for general lighting in indoor and outdoor areas with low
mounting heights or confined spaces, such as aisles, tunnels
and catwalks, over doorways or entries, landing areas, utility
rooms, etc.

D

Certifications and Compliances:
NEC Standards:
• Class I, Division 2, Groups A, B, C, D
• NEMA 4X; IP66
• Marine and Wet Locations
UL Standards:
• UL844 Electrical Fixture Hangers for Hazardous Locations
• UL1598 Luminaire
• UL1598A Luminaire for Installation on Marine Vessels
CSA Standard:
• C22.2 No. 137

Design Features:
A Luminaire is designed to match the footprint of a traditional linear

fluorescent fixture.
B Same light pattern and lumen output at a fraction of the energy

cost.
C Diffused lens reduces glare.
D Shock- and vibration-resistant LEDs contain no mercury,

eliminating costly lamp disposal programs.

Additional Features and Benefits:
Best-in-class reliability

Standard Materials:

• Linear LED solution can withstand extreme vibration that would
cause traditional technologies to fail
• Can handle temperature extremes down to -35°C where
comparable products cannot operate
• Redundant drivers housed next to LED arrays for slim profile and
superior heat dissipation
• Redundant drivers and LED modules ensure the highest factor of
safety in the industry

• Housing – copper-free aluminum with Corro-free™ epoxy powder
coat end caps and extruded aluminum body
• Lens – heat- and impact-resistant glass
• External hardware – stainless steel

2L

Electrical Ratings:
• 100VAC to 277VAC 50 / 60 Hz
• Power factor >0.9

Versatile mounting options
• Ceiling mount standard (included with fixture)
• Choice of brackets for wall or pole mounting (ordered separately);
can be mounted in any position to maintain ratings
• Luminaire uses the same mounts as eLLK/nLLK Series

Reliable performance in any environment
• T5 at 40°C, T4A at 55°C temperature ratings
• Operating temperature range: -35°C to +55°C

Ordering Information:
Cat. #

System Power

Glass Color

Entry

Lumen Output

CCT

LL48-60W-765/-F-1M
LL48-60W-765/-C-1M
LL48-60W-765/-F-1N
LL48-60W-765/-C-1N

56W
56W
56W
56W

Frosted
Clear
Frosted
Clear

M20
M20
1
/2" NPT
1
/2" NPT

3716
4380
3716
4380

Cool
Cool
Cool
Cool

922

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

White,
White,
White,
White,

6500K
6500K
6500K
6500K

922-923.qxp

12/16/2013

7:01 PM

Page 923

Cl. I, Div. 2, Groups A, B, C, D NEMA 4X; IP66
Marine and Wet Locations
UL Listed
CSA Certified

LL48 Linear
LED Luminaires

2L

For heavy industrial applications
Dimensions:

67 mm (2.64”)

1036 mm (40.79”)

200 mm (7.87”)

Mounting Styles:

Ceiling Mount
(Included with Fixture)

2L

135°
30°
Wall Mount
(Order Separately)

Pole Mount
(Order Separately)

Mounting Ordering Information:
Cat. #

Description

12329778
12329779
12329900
12329901
12329902
12329903

Ceiling Mounting Bracket Kit
Clamp for Pole Mounting 11/4" Kit
Clamp for Pole Mounting 11/2" Kit
Clamp for Pole Mounting 2" Kit
Luminaire Wall Suspension 27° Kit
Luminaire Wall Suspension 30° Kit

Photometrics:
• LM79 data available upon request

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

923

924-925.qxp

12/16/2013

2L

7:02 PM

Page 924

Champ® VMV LED Series
Luminaires
Improve safety, reliability and
energy efficiency

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL / cUL Listed
IECEx / ATEX
Simultaneous Presence
Wet Locations, Type 4X, IP66

The Champ VMV LED Family
VMV LED Series Luminaires are designed to provide full-spectrum, crisp, white light with
custom IES Type I, III and V distribution. Five versions of the Champ VMV LED are available,
providing ideal solutions for a wide range of applications.

Model

Nominal†
Lumens
(Type V)

VMV3L
VMV5L
VMV7L
VMV9L
VMV11L

3,515
5,288
7,404
9,515
10,935

Wattage

Equivalent HID
Luminaire

Typical Energy
Savings /
Lifetime

41
67
94
114
118

70W-100W
100W-150W
150W-175W
250W-400W
400W

Up
Up
Up
Up
Up

to
to
to
to
to

77%
67%
67%
74%
74%

†Tolerance +/- 10%.

Applications:
• Locations requiring continuous and
consistent light levels in extreme ambient
temperatures
• Areas requiring frequent on-and-off of
lights
• Where flammable vapors, gases,
ignitable dusts, fibers or flyings are
present; indoors or outdoors
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist
• Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; food and
beverage facilities; mining; platforms;
loading docks; tunnels; indoor/outdoor
spot lighting; outdoor wall and stanchion
mounted general area lighting

2L

Champ VMV LED Benefits:
• Instant illumination and restrike
• Better visibility with crisp, white light
• Cold temperature operation / no warm-up
required
• Redundancy in drivers with multiple series
circuits connected to each driver to avoid
complete loss of illumination
• Easy installation – compact modular
fixture attaches onto existing Champ
mounting module
• Energy-efficient technology – up to 77%
energy savings over HID fixtures
• Provides up to 60,000 hours rated life and
up to 170,000 hours of economic life –
eliminates need for frequent lamp
replacement
• Contains no mercury or other hazardous
substances
• Shock- and vibration-resistant solid-state
luminaires have no filaments or glass
components that could break – greatly
reduces the risk of premature failure
• Operating ambient -40°C to 55°C
• Dark sky compliant
• 5 year fixture warranty‡
‡Refer to page 2 of the D-0413 authorized distributor price
book for Eaton's Crouse-Hinds standard Terms and
Conditions.

Certifications and
Compliances:
• DesignLights Consortium® pending for
select models*
NEC and CEC
• Class I, Division 2, Groups A, B, C, D
• Class I, Zone 2, nA nR
• Class II, Groups E, F, G
• Class III
• Zone 21 tb
• Simultaneous Presence
• Wet Locations, Type 4X, IP66
UL Standards
• UL844
• UL1598 Luminaires, UL1598A Marine
CSA Standard
• cUL Listed to CSA Standard CSA C22.2
No. 137
IECEx/ATEX Standards
• IEC60079-0:2011/EN60079-0:2012
• IEC60079-15:2010/EN60079-15:2010
• IEC60079-31:2008/EN60079-31:2009
• IEC60529:2001/EN60529:2001
• IEC60598-1:2008/EN60598-1:2008
• IEC60598-2:2008/EN60598-2:2008
• IECEx UL 13.0052X
• DEMKO 13 ATEX 1305741X
• DEMKO 13 ATEX 1475013X**
• CE
100-277 VAC / 108-250 VDC
• Ex nA nR IIC T6 Gc -40°C to +40°C
• Ex nA nR IIC T5 Gc -40°C to +55°C
• Ex tb IIIC T72°C Db IP66 -40°C to +40°C
• Ex tb IIIC T87°C Db IP66 -40°C to +55°C
•
II 3 G Ex nA nR IIC T6 Gc -40°C to
+40°C**
•
II 3 G Ex nA nR IIC T5 Gc -40°C to
+55°C**
•
II 2 D Ex tb IIIC T72°C Db IP66 -40°C
to +40°C
•
II 2 D Ex tb IIIC T87°C Db IP66 -40°C
to +55°C
347-480 VAC
• Ex nA nR IIC T4 Gc -40°C to +55°C
• Ex tb IIIC T70°C Db IP66 -40°C to +40°C
• Ex tb IIIC T85°C Db IP66 -40°C to +55°C
•
II 3 G Ex nA nR IIC T4 Gc -40°C to
+55°C**
•
II 2 D Ex tb IIIC T70°C Db IP66 -40°C
to +40°C
•
II 2 D Ex tb IIIC T85°C Db IP66 -40°C
to +55°C
*Cool white 120-277 VAC 3L-11L models. Refer to page 2
of the D-0413 authorized distributor price book for Eaton's
Crouse-Hinds standard Terms and Conditions.

924

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Standard Materials:
• Lamp housing and adapter – die cast
aluminum with Corro-free™ epoxy
powder coat
• Lens – heat- and impact-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals
required

LED System:
• High intensity discrete power emitters
• Cool white (5000K, 70 CRI) and warm
white (3000K, 80 CRI)
• Custom optics designed to go over
each discrete LED

Custom Optics:
Three optical options to maximize light
distribution and intensity:
TYPE I
Ideal for:
• Mining conveyor belts
• Aisleways and hallways
• Catwalks and walkways
• Ramps and loading docks
• Tunnels with overhead
mounts
TYPE III
Ideal for:
• Narrow crosswalks or
passages with wall
mounted fixtures
• Tunnels with wall mount
• Wall or stanchion mount
requiring 180° forward
throw beam patterns
TYPE V
Ideal for:
• Pendant, ceiling or
stanchion mount overhead
building mounts
• Processing mills, industrial
plants, large buildings,
warehouses, etc.

Copyright© 2013 Eaton’s Crouse-Hinds Business

924-925.qxp

12/16/2013

7:03 PM

Page 925

Champ® VMV LED Series
Luminaires
Improve safety, reliability and
energy efficiency

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL / cUL Listed
IECEx / ATEX
Simultaneous Presence
Wet Locations, Type 4X,
IP66

2L

Drivers:
Option

3L - 11L

/UNV1
/UNV34**
/VDC‡

120-277 VAC, 50 / 60 Hz
347-480 VAC, 50 / 60 Hz
108-250 VDC, 50 / 60 Hz

**No separate external transformer required to step down voltage.
‡Separate driver for DC applications.

Electrical Ratings:
VMV3L

VMV5L

VMV7L

VMV9L

VMV11L

Voltage Range, VAC

120-277

120-277

120-277

120-277

120-277

Frequency

50 / 60 Hz

50 / 60 Hz

50 / 60 Hz

50 / 60 Hz

50 / 60 Hz

Input Power (Watts)

41

67

94

114

118

Input Amps at 120-277 VAC

0.34-0.17

0.57-0.29

0.80-0.42

0.96-0.49

0.96-0.49

Voltage Range, VDC

108-250

108-250

108-250

108-250

108-250

Power Factor

>0.90

>0.90

>0.90

>0.90

>0.90

Nominal Lumens† (Type V)

3,515

5,288

7,404

9,515

10,935

†Tolerance +/- 10%.

Design Features:

A

A Installation and replacement made simple - this contractor-friendly,

E
B

C

D

2L

modular design is ideal for both retrofit and new construction applications.
These luminaires are installed in the same manner and use the same
mounting modules as existing Champ® Series luminaires. The compact
modular design of the VMVL allows for easy component replacement and
future upgrade.
B High efficiency and lumen output - custom high efficiency LED drivers are
designed to provide reliable operation in even the harshest environments.
Various AC and DC input voltage options are available to suit virtually any
drive requirement.
C Safe, reliable heat transfer - die cast aluminum housing provides safe and
effective heat transfer from the LED assembly to the outside environment,
ensuring low LED junction temperature, reliability, and sustained lumen
performance. The vertical fin design facilitates air flow and dust shedding.
The impact-resistant lens is sealed from the outside environment and
provides ingress protection against water and dust.
D Custom optics - custom optics designed for discrete LED
power emitters.
E Ease of wiring and installation - available with lever lock connectors and

standard three-pole terminal block for ease of wiring and installation.

Custom Optics:
Custom optics designed for discrete LED power emitters:
• Type V standard
• Type I and Type III optional

Type I

Type III

Type V

Colored LED Options:
•
•
•
•

Available in red, blue, green and amber
Reduction in light pollution for night space observation and sky glow due to isolating blue wavelength in red and amber colors
Wildlife friendly
Improves visibility for telescopes in observatories during night sky space exploration

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

925

926-927.qxp

12/16/2013

2L

7:03 PM

Page 926

Champ® VMV LED Series
Luminaires
Improve safety, reliability
and energy efficiency

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL / cUL Listed
IECEx / ATEX
Simultaneous Presence
Wet Locations, Type 4X, IP66

Catalog Numbering System:

VMV 7L W 2A R1 G /UNV1 S890
Lamp/Function
3L

3,515 Lumen LED

5L

5,288 Lumen LED

7L

7,404 Lumen LED

9L

9,519 Lumen LED

11L

10,935 Lumen LED

RL

Red (3,200 Lumen)

/UNV1

GL

Green (4,300 Lumen)

BL

Blue (2,100 Lumen)

AL

Amber (5,000 Lumen)

Color Temperature
BLANK

W

Suffixes

Guard

Cool

BLANK

No Guard

S812

Trunnion Mount Kit with Pin

(5000 ± 200K)

G

P3001 Wire Guard

S890

Quick Clip

S891

Diffused Lens†

S896

Teflon Coated Lens†

120-277 VAC, 50/60 Hz

S903

Polycarbonate Lens

/UNV34

347-480 VAC, 50/60 Hz

TB6

Six-pole Terminal Block†

/VDC

108-250 VDC, 50/60 Hz

Warm
Voltage

(3000K ± 200K)

Mounting Style
BLANK

No Cover

J

1-½” Stanchion 25°

P

1-½” Stanchion Straight

2A
3A
2B
3B
2C
3C
2HA

Optics

¾” Pendant
1” Pendant
¾” Cone Pendant
1” Cone Pendant
¾” Ceiling
1” Ceiling
¾” Flexible Pendant

2TW

¾” Wall

3TW

1” Wall

BLANK

Type V Optic Standard (All Mounts)

R1

Type I Optic (All Mounts Minus Ceiling)

R1A

Type I Optic (Ceiling with Conduit 45° Counterclockwise or 135° Clockwise from Hinge)*

R1B

Type I Optic (Ceiling with Conduit 45° Clockwise or 135° Counterclockwise from Hinge)*

R3

Type III Optic (All Mounts Minus Ceiling)

R3A1

Type III Optic (Ceiling with Conduit 45° Counterclockwise from Top Hat Hinge)**

R3A2

Type III Optic (Ceiling with Conduit 135° Clockwise from Top Hat Hinge)**

R3B1

Type III Optic (Ceiling with Conduit 45° Clockwise from Top Hat Hinge)**

R3B2

Type III Optic (Ceiling with Conduit 135° Counterclockwise from Top Hat Hinge)**

2L

*For new construction, order R1A only.
**For new construction, order R3A1 only.
†Not available for IEC applications.

Options:
Description
Wire guard with captive mounting hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trunnion mount with redundant pin locking mechanism (ceiling mount required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Clip for quick installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diffused lens for glare reduction‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Teflon coating on lens for additional shatter protection‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Polycarbonate lens available in applications where glass is prohibited . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Six-pole terminal block‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Suffix
P3001
S812 K1
S890
S891
S896
S903
TB6

‡‡Not available for IEC applications.

Accessories (Ordered Separately):
Description
Photocell, 120V, 50 / 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Photocell, 208-277V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Occupancy sensor, 1/ 2" entry, 120 / 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Occupancy sensor, 3/ 4" entry, 120 / 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Occupancy sensor, 1" entry, 120 / 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
***For 347-480 VAC, replace /UNV1 with /UNV34.

926

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Cat. # (Ordered
Separately)
D2S20
D2S208 277
COS1/UNV1
COS2/UNV1
COS3/UNV1

926-927.qxp

12/16/2013

7:03 PM

Page 927

UL / cUL Listed
IECEx / ATEX
Simultaneous Presence
Wet Locations, Type 4X, IP66

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

Champ® VMV LED Series
Luminaires
Improve safety, reliability
and energy efficiency

2L

Dimensions:
Pendant

Ceiling

Wall

Trunnion

273.5
10.77

2X LOCKING PINS

118.6
4.67

354.6
13.96

50.8
2.00

295.2
11.62

BRACKET FOR WALL MOUNT
OR SFA6 SLIPFITTER

258.6
10.18

295.1
11.62

Cone Pendant

300.4
11.83

71.2
2.80

2X TRUNNION ROTATION
HARDWARE

117.5
4.63

51.6
2.03

158
6.22

CM2 OR CM3
TOP HAT

279.4
11.00

287.3
11.31

386.6
15.22

280.1
11.03
225.6
8.88

Stanchion Angled

2X TOP HAT MOUNTING
HARDWARE

Stanchion Straight
407.2
16.03

Weights:
88.7
3.49

382.7
15.07
53.4
2.10

273.8 45.2
10.78 1.78
326.3
12.85

282
11.10

25°

247.7
9.75

Net Luminaire Weight:

21.8 lbs.

8.07 kg.

Mounting Module add (lb.)
Pendant
Cone Pendant
Flexible Pendant
Ceiling
Wall
Angle Stanchion
Straight Stanchion

1.25
4.00
1.50
2.75
4.50
3.50
4.50

0.57
1.81
0.68
1.25
2.04
1.59
2.04

Temperature Codes:

3L, 5L, 7L,
9L, 11L‡

Driver Type

Ambient

Cl. II, Div. 1

Sim. Pres. /
Cl. I, Div. 2 /
Cl. II, Div. 1

/UNV1 (100-277 VAC)

40°C

T6

T5

T3C

T72

/VDC (108-250 VDC)

55°C
40°C
55°C
40°C

T5
T4
T4
T5

T4A
T5
T4A
T6

T3B
T3C
T3A
T4A

T87
T70
T85
T60

55°C

T4

T6

T4A

T75

/UNV34 (347-480 VAC)
RL, GL,
BL, AL

/UNV1 (100-277 VAC)

Zone 21

2L

Model

Cl. I, Div. 2 /
Zone 2, nA, nR

‡Teflon and diffused glass options are only NEC certified for: Class I, Division 2/Sim. Pres. - T3C (40°C); T3B (55°C) for /UNV1 and /VDC, and T3C (40°C); T3A (55°C) for /UNV34.
Class II, Division 1 - T5 (40°C); T4A (55°C) for /UNV1, /VDC and /UNV34.

Family Tree:
MOUNTING MODULE SERIES
PENDANT
APM2
APM3
HPM2

ANGLED
BPM2
BPM3

CEILING
CM2
CM3

WALL
TWM2
TWM3

STANCHION
PM5
JM5

VMV*L
PVM*L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

927

928-929.qxp

12/16/2013

7:04 PM

Page 928

UL / cUL Listed
IECEx / ATEX
Simultaneous Presence
Wet Locations, Type 4X, IP66

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

Champ® VMV LED Series
Luminaires

2L

Improve safety, reliability and
energy efficiency
Photometric Data:

Photometric Layout Comparison - Champ® VMV7L LED Versus 175W Metal Halide:
VMV7L - Type I

VMV 175W PSMH - Type I
50

50

40

30

20

10

0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.3

0.3

0.4

0.4

0.4

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.6

0.6

0.6

0.7

0.7

0.6

0.6

0.6

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.3

0.4

0.6

0.8

0.9

0.9

0.9

0.9

0.9

0.9

0.8

0.6

0.4

0.3

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.7

1.0

1.1

1.1

1.4

1.4

1.1

1.1

1.0

0.7

0.5

0.3

0.2

0.2

0.1

0.2

0.3

0.4

0.5

0.6

0.9

1.1

1.3

2.1

2.6

2.6

2.1

1.3

1.1

0.9

0.6

0.5

0.4

0.3

0.2

0.4

.5
0.5

0.7

1.0

1.5

2.0

2.1

2.1

3.0

2.9

2.9

3.0

2.1

2.1

2.0

1.5

1.0

0.7

0.5

0.4

1.75

40

30

20

10

0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.1

0.0

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.1

0.2

0.2

0.3

0.4

0.4

0.4

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.4

0.5

0.4

0.3

0.3

0.2

0.2

0.3

0.5

0.6

0.8

1.0

1.0

0.6

0.8

0.7

0.7

0.8

0.7

1.0

1.0

0.8

0.7

0.5

0.4

0.3

0.3

0.5

0.7

0.9

1.2

1.7

2.4

2.7

3.0

3.2

3.3

3.0

2.7

2.4

1.8

1.3

1.0

0.7

0.5

0.4

0.4.5

0.6

0.9

1.2

1.75
1.7

2.4

3.5

4.8

6.3

7.3

7.2

6.3

4.7

3.4

2.5

1.7

1.3

0.9

0.7

0.5

-20

-30

-40

-50

0.4

.5
0.5

.75
0.7

11.0

1.5
1.5

22.0

2.1

2.1

2.9

2.6

2.6

2.9

2.1

2.1

2.0

1.5

1.0

0.7

0.5

0.4

0.2

0.3

0.4

0.5

0.6

0.9

1.1

1.2

1.9

2.4

2.4

1.9

1.2

1.1

0.9

0.6

0.5

0.4

0.3

0.2

0.1

0.2

0.2

0.3

0.5

0.7

1.0

1.1

1.0

1.3

1.3

1.0

1.1

1.0

0.7

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.3

0.4

0.6

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.6

0.4

0.3

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.5

0.6

0.6

0.6

0.6

0.6

0.6

0.5

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.3

0.3

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

-10

-20

-30

-40

-50

0.4.5

0.6

0.3

0.5

.75

0.9 1

1.2

0.7

0.9

1.5

1.7 2

2.4

1.2

1.7

3

3.5 4

5
4.8

2.4

2.7

-40

-30

-20

-10

0

6

7

6.3

3.0

7.3

7.2

6.3

4.7

3.4

2.5

1.7

1.3

0.9

0.7

0.5

3.2

3.3

3.0

2.7

2.4

1.8

1.3

1.0

0.7

0.5

0.4

0.2

0.3

0.5

0.6

0.8

1.0

1.0

0.6

0.8

0.7

0.7

0.8

0.7

1.0

1.0

0.8

0.7

0.5

0.4

0.3

0.2

0.2

0.3

0.4

0.4

0.4

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.4

0.5

0.4

0.3

0.3

0.2

0.1

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

Point By Point Foot-Candles

-50

0.25

7L Type I

VMVM2C175G241-S828

-10

TYPE I OPTICAL PATTERN

20

30

40

50

-50

-40

-30

-20

-10

0

10

20

30

40

1

1.25

1.5

2

4

3

5

6

7

Calculation Summary

Point By Point Foot-Candles

10

Distance In Feet

0.75

Label

Calc. Type (in Fc)

Avg.

Max.

Min.

VMV 175W MH Grid

Illuminance

0.49

3.0

0.0

VMV LED Grid

Illuminance

0.58

7.3

0.0

50

Distance In Feet

VMV7L - Type III

VMV 175W PSMH - Type III
50

50

40

30

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.2

0.2

0.3

0.3

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.3

0.3

0.4

0.4

0.4

0.4

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.4

0.4

0.4

0.4

20

0.5

0.6

0.4

0.5

0.6

0.5

0.4

0.6

0.8

1.0

1.1

1.2

1.1

0.7

0.8

0.8

0.9

0.9

0.8

0.8

0.7

1.1

1.2

1.1

1.0

0.8

0.6

10

0.5

0.7

11.0

1.5

1.9

2.1

1.8

1.2

1.1

1.1

1.1

1.1

1.2

1.8

2.1

1.9

1.5

1.0

0.7

0.5

0.7

0.7

2.5

0.5

0.8

1.2

1.72

2.6

.25
0.2

0.3

0.5

0.7

1.0

1.5

2.0

2.0

0.2

0.2

0.3

0.4

0.6

0.9

1.3

1.6

0.2

0.2

0.3

0.4

0.5

0.8

1.0

0.1

0.2

0.3

0.4

0.5

0.7

0.1

0.2

0.2

0.3

0.4

0.6

0.1

0.2

0.2

0.3

0.3

0.4

0.1

0.1

0.2

0.2

0.3

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.4

0

0.6

.5

1.5

0.6

0.7

0.7

0.6

0.6

0.6

0.7

0.7

0.6

2.4

3.3

2.9

2.6

1.7

1.2

0.8

0.5

0.4

3.7

2.0

2.0

1.5

1.0

0.7

0.5

0.3

0.2

3.8

2.8

2.8

3.8

1.6

1.3

0.9

0.6

0.4

0.3

0.2

0.2

1.2

1.5

2.9

2.9

1.5

1.2

1.0

0.8

0.5

0.4

0.3

0.2

0.2

0.9

1.0

1.1

1.2

1.2

1.1

1.0

0.9

0.7

0.5

0.4

0.3

0.2

0.1

0.7

0.9

0.9

0.9

0.9

0.9

0.9

0.7

0.6

0.4

0.3

0.2

0.2

0.1

0.5

0.6

0.7

0.7

0.7

0.7

0.6

0.5

0.4

0.3

0.3

0.2

0.2

0.1

0.3

0.4

0.4

0.4

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

2.0

4

3.3

2.4

3.7

4.5

2.0

30

0.5

4.5

2.9

40

20

10

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.5

0.6

0.6

0.6

0.6

0.5

0.4

0.3

0.2

0.2

0.2

0.1

0.1

1.1

1.2

1.2

0.7

0.1

0.2

0.2

0.3

0.4

0.5

0.7

0.9

0.2

0.2

0.3

0.4

0.5

0.7

1.1

1.5

2.0

2.4

0.2

0.2

0.3

0.5

0.7

1.0

1.6

2.6

3.5

4.3

0.2

0

0.3

0.4

0.2

0.3

0.4

0.2

.25
0.3

0.4

-10

0.2

0.2

-20

0.1

0.1

0.1

-30

-40

-50

-40

-30

-20

-10

0

0.4

0.3

0.2

1.5

1.1

0.7

0.5

0.4

0.3

0.2

0.2

2.6

1.6

1.0

0.7

0.5

0.3

0.2

0.2

6.4

7.6

0.5

0.2

0.1

5.4

3.5

7.6

6.2

3.9

2.3

1.4

0.9

0.6

0.4

0.3

0.2

4.6

5.9

5.9

4.6

2.9

1.8

1.2

0.8

0.5

0.4

0.3

0.2

1.0

1.4

2.2

4.0

4.0

2.2

1.4

1.0

0.8

0.6

0.4

0.3

0.2

0.2

0.4

0.5

0.5

0.9

1.3

1.3

0.9

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.1

0.2

0.2

0.3

0.5

0.6

0.6

0.5

0.3

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.3

0.3

0.3

0.3

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.8

1.3

0.3

0.4

0.6

0.8

0.2

0.2

0.3

0.4

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

2.1

1.4

2

1.2

1.5

3.5

2.3 3

3.9

5

6

6.4

2.1

1.3

0.8

0.5

0.4

0.3

0.2

0.25

coo173140

-10

-20

-30

-40

-50

.5

1

1.8

2.5

Point By Point Foot-Candles

-50

0.9

2.0

3.5

6.2

0.8

0.9

0.5

VMVM2C175G243-S828
3

1.1

2.4

4.3

2.9

0.5

0.6

5.4

4

TYPE III OPTICAL PATTERN

20

30

40

50

-50

-40

-30

-20

-10

10

20

30

40

1.5

2.5

2

4

3

5

6

Label

Calc. Type (in Fc)

Avg.

Max.

Min.

VMV 175W MH Grid

Illuminance

0.59

4.5

0.1

VMV LED Grid

Illuminance

0.61

7.6

0.0

50

Distance In Feet

2L

Distance In Feet

0

1

Calculation Summary

Point By Point Foot-Candles

10

0.5

VMV 175W PSMH - Type V

VMV7L - Type V
50

50
0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.4

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.5

0.6

0.7

0.7

0.7

0.7

0.6

0.5

0.3

0.3

0.2

0.2

0.1

0.1

20

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.8

0.9

1.0

1.0

0.9

0.8

0.7

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.9

1.1

1.2

1.3

1.3

1.2

10

0.1

0.2

0.2

0.4

0.6

0.8

1.1

1.3

1.4

1.7

1.7

1.4

1.3

1.1

0.8

0.6

0.4

0.2

0.2

0.1

0.1

0.2

0.3

0.4

0.7

0.9

1.2

1.4

2.2

2.8

2.8

2.2

1.4

1.2

0.9

0.7

0.4

0.3

0.2

0.1

2.8

2.6

2.6

2.8

1.7

1.3

1.0

0.7

0.5

0.3

0.2

0.1

2.8

2.6

2.6

2.8

1.7

1.3

1.0

0.7

0.5

0.3

0.2

0.1

2.2

2.8

2.8

2.2

1.4

1.2

0.9

0.7

0.4

0.3

0.2

0.1

40

30

0

0.1

0.2

0.3

0.5

0.7

1.0

1.3

0.1

0.2

0.3

0.5

0.7

11.0

1.3

-10

0.1

0.2

0.3

0.4

0.7

0.9

1.2

1.1

1.75
1.7

1.1

0.9

0.7

0.5

0.3

0.2

0.2

40

30

20

0.1

10

0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.2

0.3

0.3

0.2

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.2

0.5

0.8

1.1

1.1

0.9

0.6

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.2

0.6

1.3

2.1

2.6

2.6

2.3

1.5

0.8

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.4

1.3

2.6

3.9

4.9

4.9

4.1

2.8

1.6

0.6

0.2

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.2

0.8

2.0

3.9

5.8

7.2

7.2

6.1

4.2

2.3

1.0

0.3

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.1

7
7.1

6.5

5
5.1

2.8

1.3

0.4

0.1

0.0

0.0

0.0

7.1

6.5

6.4

7.3

5.1

2.8

1.3

0.4

0.1

0.0

0.0

0.0

5.8

7.2

7.2

6.1

4.2

2.3

1.0

0.3

0.1

0.0

0.0

0.0

1.6

0.6

0.2

0.1

0.0

0.0

0.3

.75

1.0

1.75

2.5

4.8

-20

-30

-40

-50

1.7

1.4

2

0.1

0.2

0.2

0.4

0.6

.75 0.8

1.3

1.4

1.7

1.7

1.4

1.3

1.1

0.8

0.6

0.4

0.2

0.2

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.9

1.1

1.2

1.3

1.3

1.2

1.1

0.9

0.7

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.8

0.9

1.0

1.0

0.9

0.8

0.7

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.5

0.6

0.7

0.7

0.7

0.7

0.6

0.5

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.4

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

.5

1
1.0

2

2.5

0.8

1.5

2.0

-40

-30

-20

-10

0

10

4

7.3

0.0

0.0

0.0

0.1

0.3

-10

0.0

0.0

0.0

0.1

0.2

0.0

0.0

0.0

0.1

0.1

0.4

1.3

2.6

-20

0.0

0.0

0.0

0.0

0.1

0.2

0.6

1.3

2.1

2.6

2.6

2.3

1.5

0.8

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.2

0.5

0.8

1.1

1.1

0.9

0.6

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.2

0.3

0.3

0.2

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

-30

-40

-50

.5

Point By Point Foot-Candles

-50

6.4

0.5

7L Type V

VMVM2C175G245-S828
1.5

TYPE V OPTICAL PATTERN

3

4.8

3.9

6

3.9

4.9

4.9

4.1

2.8

30

40

50

-50

-40

-30

-20

-10

0

10

20

30

40

1

1.5

1.75

3L

5L

7L

9L

11L

Type I

3,115

4,687

6,562

8,437

9,692

Type III

3,271

4,921

6,890

8,859

10,177

Type V

3,515

5,288

7,404

9,519

10,935

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

4

5

6

Calc. Type (in Fc)

Avg.

Max.

Min.

VMV 175W MH Grid

Illuminance

0.51

2.8

0.1

VMV LED Grid

Illuminance

0.69

7.3

0.0

50

†Tolerance +/- 10%.

928

3

Label

Distance In Feet

Actual Lumens
(Nominal†)

2

Calculation Summary

0.0

Point By Point Foot-Candles

20

Distance In Feet

0.75

Copyright© 2013 Eaton’s Crouse-Hinds Business

7

928-929.qxp

12/16/2013

7:04 PM

Page 929

Champ® FMV LED Series
Floodlight Fixtures

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

FMV LED Series Floodlights are designed
to provide full-spectrum, crisp, white light.
Five versions of the Champ FMV LED are
available, providing ideal solutions for a
wide range of applications.
Equivalent MH
HID Lamp

Energy
Savings

FMV
FMV
FMV
FMV
FMV

100W-150W
150W-175W
175W-250W
250W-400W
400W

Up to
62%!

5L
7L
9L
11L
13L

Reduce operation and
maintenance costs
• Easy installation - compact modular fixture
attaches onto existing SFA6 and SWB6
• Energy-efficient technology – use up to 1/ 2
the power of standard HID luminaires
• Provides up to 60,000 hours rated life –
eliminates need for frequent lamp replacement
• Contains no mercury or other hazardous
substances

Reliable performance in any
environment

Applications:
• Five lumen outputs allow for installation
in numerous mounting heights
• Locations requiring continuous and
consistent light levels in extreme
ambient temperatures
• Areas requiring frequent on-and-off of
lights
• Where flammable vapors, gases,
ignitable dusts, fibers or flyings are
present; indoors or outdoors
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist
• Type 4X, marine, wet locations, and
hose-down environments
• Indoor and outdoor area lighting in
plants, buildings, and parking areas
• Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; platforms;
loading docks; outdoor mounted general
area lighting

Option 1
Option 2

5L - 13L
90-305 VAC, 50 / 60 Hz;
108-250 VDC
347 VAC Model
480 VAC Model

Champ FMV LED Benefits:
Enhance safety and productivity
• Instant illumination and restrike
• Better visibility with crisp, white light
• Minimum T4 temperature rating – safely
operate in the most hazardous
environments and any non-hazardous
location
• Cold temperature operation / no warm-up
required

Electrical Ratings:

• Shock- and vibration-resistant solid-state
luminaires have no filaments or glass
components that could break – greatly
reduces the risk of premature failure
• Operating ambient -40°C to 55°C
• Dark sky friendly with optional visor

Certifications and
Compliances:
• DesignLights Consortium® approved for
select models (refer to Ordering
Information for details)
NEC and CEC
• Class I, Division 2, Groups A, B, C, D
• Class I, Zone 2
• Class II, Groups E, F, G
• Class III
• Simultaneous Presence
• Wet Locations, Type 4X, IP66
UL Standards
• UL844
• UL1598 Luminaires, UL1598A Marine
CSA Standard
• CSA C22.2 No. 137
IECEx/ATEX
• IECEx UL 11.0054X
• Ex nA nR IIC T4 Gc Tamb -30°C to +55°C
• Ex nA nR IIC T5 Gc Tamb -30°C to +40°C
• Ex tc IIIC T68°C Dc IP66 Tamb -30°C to
40°C
• DEMKO 12 ATEX 115535X
• Ex II 3 G Ex nA nR IIC T4 Gc Tamb
-30°C to +55°C
• Ex II 3 G Ex nA nR IIC T5 Gc Tamb
-30°C to +40°C
• Ex II 3 D Ex tc IIIC T68°C Dc IP66 Tamb
-30°C to +40°C
• CEPEL Ex-1956/10

FMV 5L

FMV 7L

FMV 9L

Standard Materials:
• Housing – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens – shatter-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals
required

LED System:
• High brightness light emitting diode
(LED) arrays
• Color temperature: 3000K (CRI 82) and
5600K (CRI 65) options available
• Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions
• LM-80 reports available upon request

Options:
Description
Suffix
Fused (only applies to
UNV1 model, not available
for 347V or 480V;
NOT marine or cUL Listed)
(NEC version only) . . . . . . . . . . . S658
Two conduit/cable glands of
like thread installed . . . . . . . . . . S886

Accessories
(Order Separately):
Description
Bolt-on visor
(sold separately) . . . . . . . . . . . .
Bolt-on wire guard
(sold separately) . . . . . . . . . . . .
Floodlight slipfitter
(sold separately) . . . . . . . . . . . .
Slipfitter wall mount adapter
(sold separately) . . . . . . . . . . . .

FMV 11L

Cat. No.
DSV1
P61
SFA6
SWB6

FMV 13L

100-277V 50 / 60 Hz

Voltage Range, VAC

347 / 480V 60 Hz

Voltage Range, VDC

108-250

108-250

108-250

108-250

108-250

Input Power (Nom.)

64

89

121

149

179

Input Amps (Max.)

0.550

0.800

1.083

1.608

1.608

Power Factor

>0.85

>0.85

>0.85

>0.85

>0.85

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

929

2L

Drivers:
Model
Standard

2L

• “No lights out” feature – if a single LED
fails, others will remain lit from other
drivers – minimum 50% output maintained
• Terminals – 3 x 6 sq. mm. for IEC version

The Champ FMV
LED Family

FMV
Model

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

930-931.qxp

2L

12/16/2013

7:40 PM

Page 930

Champ® FMV LED Series
Floodlight Fixtures

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

Safe, reliable heat transfer

Installation and replacement made simple

The heat sink was designed to perform in
high ambient temperatures up to +55ºC and
as low as -40ºC. The thick walls of the
castings make for a tough, rugged housing
that keeps the internal driver and LED
temperatures down, allowing them to
perform flawlessly, and protects them from damage. Separated driver
and LED housing allows dust to shed from fixture.

The full-frame yoke was designed to utilize the SFA6 slipfitter
and SWB6 wall mount bracket (sold separately), making it
ideal for retrofit or new installations. The modular design of
the FMV LED allows for easy driver or LED replacement, and
allows for the addition of the optional visor or guard in the
field. Single cable gland provided with a second plugged
cable entry, if an additional cable gland is needed.

High efficiency and lumen output

2L

High efficiency drivers and LED arrays provide
reliable low cost operation in harsh and
hazardous environments. Components were
chosen to give industry-leading light output from
an LED flood. Replaceable drivers and LEDs for
ease of maintenance and “no lights out” feature.

Versatile design
Suitable for hazardous location use in gas
or dust areas. Can be used for outdoor or
indoor applications, and for a wide range of
mounting heights depending on model and
light level requirement. Optics were
specifically designed to give the familiar
and industry-accepted butterfly beam light
pattern.

930

www.crouse-hinds.com

US: 1-866-764-5454

Optional equipment
Cool (C) and Warm (W) white color temperatures available.
Optional visor offered (sold separately) to control light spill.
Optional wire guard offered (sold separately) to protect lens from damage.
Other options available - consult part numbering guide.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

930-931.qxp

12/16/2013

7:40 PM

Page 931

Champ® FMV LED Series
Floodlight Fixtures

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

2L

Catalog Numbering System:
SERIES

LIGHT
SOURCE

COLOR

MOUNT

VOLTAGE

OPTICAL
DISTRIBUTION

SUFFIXES

FMV

9L

C

Y

/UNV1

76

S658

SERIES
FMV
NFMV

NEC version with Class/Division ratings
IEC version with Class/Zone ratings

LIGHT SOURCE / INTENSITY
5L
7L
9L
11L
13L

100W - 150W equivalent
150W - 175W equivalent
175W - 250W equivalent
250W - 400W equivalent
400W equivalent

COLOR TEMPERATURE
C
W

5600K (cool white)
3000K (warm white)

MOUNT
Y

Yoke

VOLTAGE
/UNV1
/120
/347
/480

100 VAC to 277 VAC 50/60 Hz, 108 VDC to 250 VDC
120 VAC 50/60 Hz**
347 VAC 60 Hz
480 VAC 60 Hz

OPTICAL DISTRIBUTION
76

Floodlight pattern optics included

ADDITIONAL ITEMS (SOLD SEPARATELY)

SUFFIXES
20mm metric threads for conduit opening (NFMV only)*
25mm metric threads for conduit opening (NFMV only)*
Fused; for UNV1 only; not for marine or cUL
Two conduit/cable glands of like thread installed

DSV dark sky visor
Wire guard factory installed
Floodlight slipfitter
Slipfitter wall mount adapter

2L

M20
M25
S658
S886

DSV1
P61
SFA6
SWB6

*Required for NFMV. Please specify conduit entry.
**5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton’s Crouse-Hinds standard Terms and Conditions.
DesignLights Consortium® approved models. Cool white only.

Dimensions:
[532.9]
21.0

[167.1]
6.6

[552.5]
21.75

[405.9]
16.0

[120.7]
4.75

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

[14]
Ø.55

Copyright© 2013 Eaton’s Crouse-Hinds Business

931

932-933.qxp

12/16/2013

7:05 PM

Page 932

Champ® FMV LED Series
Floodlight Fixtures

2L

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

Photometric Data:
FMV 13L @ 40 Ft. High; Tilt Angle = 45 Degrees
(Isofootcandles)

Point By Point FC Readings

Distance in Feet

.35 Fc

.5 Fc

1 Fc

2 Fc

2.5 Fc

MULTIPLIERS FOR OTHER LED FLOODLIGHTS
Luminaire
Series

Wattage

Lumens*

FMV 5L

64

4386

FMV 7L

89

6720

FMV 9L

121

8478

FMV 11L

149

10420

2L

*FMV 13L output is 12,940.

Weights:
Model

Lbs.

Kg.

5L
7L
9L
11L
13L

39.11
39.16
39.73
40.35
40.35

17.74
17.76
18.02
18.30
18.30

Ambient Temperature:
Max. Temp. ºC
FMV 5L
FMV 7L
FMV 9L
FMV 11L
FMV 13L

932

Cl. I, Div. 2

Cl. I, Zone 2

Simu. Presence Div. 1 and Div. 2

Cl. II, Div. 1

Cl. III

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

932-933.qxp

12/16/2013

7:05 PM

Page 933

Vaporgard™ LED
Series Luminaires
Leading the way in LED technology for
industrial and hazardous applications

Cl. I, Div. 2,
Groups A, B, C, D
Cl. II, Div. 1,
Groups F, G
IECEx/ATEX

The Vaporgard LED Family:
V2LC/UNV - Cool White Color
Temperature
The V2LC/UNV Luminaire provides
uniform crisp, white light and is
suitable for lower mounting heights,
confined spaces, tunnels, or utility
rooms. Using four high power, high
brightness LED arrays, this fixture can
deliver similar light levels to 150 watt incandescent.
V2LW/UNV - Warm White Color Temperature
The V2LW/UNV Luminaire provides similar benefits as the cool white
version, but with a color rendering more consistent with a warm
incandescent or HPS lamp source. Perfect for situations where
Vaporgard LED will be installed next to a warmer color light source.
DC Power Supply - Available for Applications Requiring DC Power
For applications with DC power requirements such as solar or back-up
battery. The DC power supply is suitable for 12VDC through 24VDC.

Applications:
Vaporgard LED Luminaires are ideal for use in:
• Wet, dirty, dusty, corrosive, hot/cold conditions
• Hazardous locations
• Confined space or low ceiling areas, such as tunnels, utility rooms,
over doorways or entries, top of landings, etc.
• Areas requiring frequent on/off of lights
• Areas where maintenance is difficult or challenging
• Areas requiring shatter-protected products, such as food processing
facilities
• Outdoor wall or ceiling mounted area illumination
• Low mounting heights

Vaporgard LED Benefits:
Enhance safety and productivity
Instant illumination and restrike
Cold temperature operation; no warm-up time
Multi-die LED arrays improve reliability
Lightweight, low profile, and cool surface temperatures
Driver with internal fusing for branch circuit protection
22 watt LED system can save up to 85% in energy costs
50K hours rated life can provide >10 years of maintenance-free lighting
No mercury or hazardous chemicals - eliminates disposal concerns
Mounts to existing Vaporgard mounting modules

Reliable performance in any environment
• Shock- and vibration-resistant
• Teflon coated lens (suffix S896) option for increased safety in food
processing facilities
• Low starting temperature: -30°C
• Operating ambient: -30°C to 55°C (High Temperature Option)
• Dark sky compliant

• Body and mounting modules – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens bezel – aluminum with anodized finish
• Lens – heat- and impact-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals required

LED System:
•
•
•
•
•
•

(4) High brightness LED arrays
Cool white (5600K), CRI 65
Warm white (3000K), CRI 82
70% lumen maintenance (L70) at 50K hours
Junction temperature Tj <90°C ensures long life
Array complies with requirements of IEC LM80

LED Drivers:
•
•
•
•
•
•
•
•

Constant current regulated power supply
90VAC - 264VAC, 277VAC, 50/60Hz
Internal fusing
Active power factor correction, >0.9
Low harmonic distortion, <20%
Low inrush current, <20 amps
EMC compliant to 47CFR, Part 2, Part 15
12VDC/24VDC option available

Description
Suffix
Frosted lens reduces glare in applications where the user
may have direct visual contact with the light source
(NEC version only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S891
Teflon coating on lens provides additional shatter protection
for applications in food and beverage facilities
(NEC version only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

S896

High temperature option allows operation up to 55°C ambient
temperature (AC unit only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . S902
BR

Brazil (CEPEL) certification (IEC version only) . . . . . . . . . . . . .

Electrical Ratings:
Series
V2LC/UNV1* V2LW/UNV1 V2LC/DC1 V2LW/DC1
90-264VAC, 90-264VAC,
12-24VDC 12-24VDC
277VAC
277VAC
Input Power (Watts)
22
22
22
22
Voltage

Certifications and Compliances:
• RoHS Compliant
• DesignLights Consortium® approved for select models (refer to
Ordering Information for details)
NEC and CEC
• Class I, Division 2, Groups A, B, C, D
• Class II, Division 1, Groups F, G
• NEMA 4X
UL Standards
• IP66
• UL844
www.crouse-hinds.com

Standard Materials:

Options:

Reduce operation and maintenance costs
•
•
•
•

• UL1598A Marine
• UL1598 Wet Locations
CSA Standard
• CSA C22.2 No. 137
IECEx/ATEX
• Ex II 3 G Ex nA IIC T4 Gc (T4 at 55°C)
• Ex II 3 D Ex tc IIIB T69°C Dc IP66
• EN60079-0:2009, EN60079-15:2010, EN60079-31:2009

US: 1-866-764-5454

Input Current

0.23 / 0.10

0.23 / 0.10

2.1 / 1.0

Power Factor

>0.9

>0.9

N/A

2.1 / 1.0
N/A

THD (I) (%)

<20%

<20%

N/A

N/A

Maintained Lumens

1633

1400

1633

1400

Efficacy, LPW

64

56

64

56

Color Temperature

5600K

3000K

5600K

3000K

*5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book
for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium
approved models.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

933

2L

•
•
•
•
•

2L

UL Listed & CSA Certified
Wet Location
NEMA 4X
IP66

934-935.qxp

12/16/2013

7:07 PM

Page 934

Vaporgard™ LED
Series Luminaires

2L

Leading the way in LED technology for
industrial and hazardous applications

Cl. I, Div. 2,
Groups A, B, C, D
Cl. II, Div. 1,
Groups F, G
IECEx/ATEX

UL Listed & CSA Certified
Wet Location
NEMA 4X
IP66

Installation and replacement made simple

Safe, reliable heat transfer

This contractor-friendly design is ideal for both
retrofit and new construction applications. These
luminaires are installed using the same wall and
ceiling mounting modules as existing Vaporgard
fixtures.

Heat sink - engineered to safely and effectively
remove heat from the LED and the driver, while
providing durable protection for the optical
elements of the fixture. This unique design
increases overall flexibility of the luminaire by
reducing both driver temperature and junction
temperature of the LED arrays.

Easy Maintenance and Component Replacement
The compact and modular design of the Vaporgard LED allows
for both easy component replacement and future upgrade.

Unique domeless, low profile design

2L

Unique domeless, low profile design for low mounting heights
and confined spaces where incandescent and HID based
luminaires are too large to fit the mechanical envelope
required.

LED Arrays
Four high power multi-die LED arrays
provide instant on and full illumination
throughout specified operational
temperature range. Since LEDs contain no
filament or lamp, the fixture can survive
even the harshest environmental conditions
and exposure to high, repeated vibration.

934

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

934-935.qxp

12/16/2013

7:07 PM

Page 935

UL Listed & CSA Certified
Wet Location
NEMA 4X
IP66

Cl. I, Div. 2,
Groups A, B, C, D
Cl. II, Div. 1,
Groups F, G
IECEx/ATEX

Vaporgard™ LED
Series Luminaires
Leading the way in LED technology for
industrial and hazardous applications

2L

Ordering Information - NEC and CEC:
Cool White

Warm White

Mounting Style

AC Drive

DC Drive

AC Drive

DC Drive

/2” Pendant*

V2LCA1/UNV1***

V2LCA1/DC1

V2LWA1/UNV1

V2LWA1/DC1

1
3

/4” Pendant*

V2LCA2/UNV1***

V2LCA2/DC1

V2LWA2/UNV1

V2LWA2/DC1

1” Pendant*

V2LCA3/UNV1***

V2LCA3/DC1

V2LWA3/UNV1

V2LWA3/DC1

/2” Wall with Junction Box

V2LCHBF1/UNV1***

V2LCHBF1/DC1

V2LWHBF1/UNV1

V2LWHBF1/DC1

/4” Wall with Junction Box

V2LCHBF2/UNV1***

V2LCHBF2/DC1

V2LWHBF2/UNV1

V2LWHBF2/DC1

/2” Ceiling

V2LCHF1/UNV1***

V2LCHF1/DC1

V2LWHF1/UNV1

V2LWHF1/DC1

/4” Ceiling

V2LCHF2/UNV1***

V2LCHF2/DC1

V2LWHF2/UNV1

V2LWHF2/DC1

/2” VXT Wall

V2LCHT1/UNV1***

V2LCHT1/DC1

V2LWHT1/UNV1

V2LWHT1/DC1

/4” VXT Wall

V2LCHT2/UNV1***

V2LCHT2/DC1

V2LWHT2/UNV1

V2LWHT2/DC1

/2” VXW Wall*

V2LCHW1/UNV1***

V2LCHW1/DC1

V2LWHW1/UNV1

V2LWHW1/DC1

3

/4” VXW Wall*

V2LCHW2/UNV1***

V2LCHW2/DC1

V2LWHW2/UNV1

V2LWHW2/DC1

11/4” Stanchion*

V2LCHJ4/UNV1***

V2LCHJ4/DC1

V2LWHJ4/UNV1

V2LWHJ4/DC1

Adapter Only**

V2LCHR/UNV1***

V2LCHR/DC1

V2LWHR/UNV1

V2LWHR/DC1

1
3
1
3
1
3
1

*For use in Class I, Division 2 or Class II, Division 1, Groups F, G. For Class II, you must order complete catalog number (not available for purchase in components).
**For use when wall mount or ceiling mount box is already installed.
***5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium® approved
models. Cool white only.

Dimensions:

Ordering Information - IECEx/ATEX:
Cool White

Warm White

AC Drive

AC Drive

/2” Pendant

NV2LCA1/UNV1

NV2LWA1/UNV1

3

/4” Pendant

NV2LCA2/UNV1

NV2LWA2/UNV1

1” Pendant

NV2LCA3/UNV1

NV2LWA3/UNV1

/2” Wall with Junction Box

NV2LCHBF1/UNV1

NV2LWHBF1/UNV1

/4” Wall with Junction Box

NV2LCHBF2/UNV1

NV2LWHBF2/UNV1

1
3

NV2LWHF1/UNV1

/4” Ceiling

NV2LCHF2/UNV1

NV2LWHF2/UNV1

4 3/4
[121.3]

NV2LCHT1/UNV1

NV2LWHT1/UNV1

/4” Wall

NV2LCHT2/UNV1

NV2LWHT2/UNV1

11/4” Stanchion

NV2LCHJ4/UNV1

NV2LWHJ4/UNV1

8 3/4
[221.7]

4 1/2
[114.7]
4 11/16
[119.8]
3 7/8
[99.2]

VLA1 1/2" NPT HUB
VLA2 3/4" NPT HUB
VLA3 1" NPT HUB

1
[25.4]
1 3/4
[44]

1 3/4
[44]

2 1/8
[53.9]

7 1/16
1 [179.7]
[25.4]

1
[25.4]

1 3/4
[44]

Stanchion

Ceiling

Note: For IEC applications, you must order complete catalog number (not available for purchase in
components).

5 7/8
[149.1]
1 3/4
[44]

1/4
[5.6]
1
[25.4]

2L

/2” Wall

3

1

15/16
[23.9]

3 7/8
[99]

NV2LCHF1/UNV1

3

6 7/8
[175]

3/4" NPT HUB
1/2" REDUCER
SUPPLIED

/2” Ceiling

1

11 1/4
[285.1]

8 3/4
[221.7]

Mounting Style
1

Wall

Pendant

8 3/4
[221.7]

11 13/16
[299.9]

8 1/8
[206.7]

Weights:
Luminaire & Mounting Module Weight

Lbs.

Pendant Mount
Ceiling Mount
Wall Mount
Stanchion Mount

5.7
6.8
7.9
6.5

Ø4 9/16
[Ø116.0]

Ø1/4
[Ø7.1]

1-1/4" HUB

Ø4 15/16
[125.2]

5

1/2” NPT OR 3/4" NPT HUB

3 7/8
[98.5]

2 1/8
[53.4]

5 3/4
[146.2]
8 3/4
[221.7]

Family Tree:

Temperature Ratings:
Max.
Temp. °C

Temp.
Rating†

V2LC/UNV1
V2LC/UNV1 S902
V2LC/DC1

40
55
40

T5
T4A
T5

NV2LC/UNV1

40

T4

NV2LC/UNV1 S902

55

T4

Class I, Div. 2; Class II, Div. 1, Gr. F&G

VXJ4

VXW2
VLA1
VLA2
VLA3

†Contact your local sales representative for warm white
temperature ratings.

www.crouse-hinds.com

45°

VXT20
VXF 10 VXFT 10
VXF 20 VXFT20

VLHR

V2L LED
Housing

US: 1-866-764-5454

Class I, Div. 2; Class II, Div. 2, Gr. F&G

VXF 10 VXFT 10
VXF 20 VXFT20

CAN: 1-800-265-0502

VAPORGARD V2L SERIES
Complete luminaire consists of LED
Housing and Cover: a VLA pendant, or
a VLHR adapter and VX series
mounting module shown.

Copyright© 2013 Eaton’s Crouse-Hinds Business

935

936-937.qxp

12/16/2013

7:09 PM

Page 936

Vaporgard™ LED
Series Luminaires

2L

Leading the way in LED technology for
industrial and hazardous applications

UL Listed & CSA Certified
Wet Location
NEMA 4X
IP66

Cl. I, Div. 2,
Groups A, B, C, D
Cl. II, Div. 1,
Groups F, G
IECEx/ATEX

Photometric Data:
Vaporgard™ LED (22 Watt)

DISTANCE TO MOUNTING HEIGHT
Isofootcandle chart shows illuminance in
foot-candles at ground level
3

CANDLEPOWER DISTRIBUTION (IN CANDELAS)

2
1
0
-1
-2
1000

-3

1500

-3

-2

-1

0

1

2

3

2000

ISOFOOTCANDLE CHART

2500

Footcandle Values for Isofootcandle Lines
3000
3500
A

4000

B

C

D

E

F

4500
5000

2L

5500

ZONAL LUMENS

936

ZONE

LUMENS

% LUMEN

0-30

468

28.65

0-40

772

47.30

0-60

1374

84.15

0-90

1633

100.00

40-90

860

52.70

60-90

259

15.85

90-180

0

0.00

0-180

1633

100.00

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Mtg.
Hgt.

A

B

C

D

E

F

6’

10.00

5.00

2.00

1.00

0.50

0.20

8’

5.62

2.81

1.13

0.56

0.28

0.11

10’

3.60

1.80

0.72

0.36

0.18

0.07

12’

2.50

1.25

0.50

0.25

0.13

0.05

14’

1.84

0.92

0.37

0.18

0.09

0.04

Copyright© 2013 Eaton’s Crouse-Hinds Business

936-937.qxp

12/16/2013

7:09 PM

Page 937

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 2
Cl. II, Div. 2, Groups F, G
Wet Locations, Marine
NEMA 3, 3R, 4X
Ambient 0ºC to 55ºC

N2LPS LIGHT-PAK™
Emergency Lighting System

Applications:
LED N2LPS Light-Pak™ emergency
lighting systems are used:
• To provide reliable illumination for egress
areas during failure or interruption of
power to the normal lighting system
• In areas where flammable gases or
vapors may become present due to
abnormal, unusual, or accidental
conditions
• In manufacturing plants, refineries,
petrochemical and chemical plants,
waste and sewage treatment facilities, oil
terminals, food processing facilities,
breweries, and other industrial
manufacturing or process industry
facilities subject to wet or corrosive
conditions
• To illuminate machinery or panels during
a loss of AC power
• Where moisture, dirt, dust, or corrosion
will limit the life and reliability of ordinary
emergency lighting systems
• Where required by the National Electrical
Code®, the Life Safety Code® or other
applicable codes
• Outdoor applications

Features:

Certifications and
Compliances:
NEC/CEC:
• Class I, Division 2, Groups B, C, D,
Zone 2
UL Standards:
• 1598A (Supplemental Requirements for
Luminaires for Installation on Marine
Vessels)
• 924 (Emergency Lighting and Power
Equipment)
• 844 (Electric Luminaires Hazardous
Locations)
CSA Standards:
• C22.2 No. 141-M1985 unit equipment for
emergency lighting
• C22.2 No. 137-M1981 non-incendive
electrical equipment for use in Class I,
Division 2 hazardous locations
• Life Safety Code NFPA101® –
Section 5-9 (Emergency Lighting)
• Marine wet locations suitability, Type 4X

Standard Materials:
• Power supply and remote luminaire
enclosures – Krydon® fiberglassreinforced polyester
• LED lamp head assembly – epoxy
powder coated stainless steel
• Exterior hardware – nylon, plastic coated,
and stainless steel
• Cover gasket – Hypalon® synthetic
rubber

Temperature Performance
Data:
Based on 55°C ambient
Class I,
Cat. #
Division 2
N2LPS (all)
N2RF (all)
Note:

40ºC - T5;
55ºC - T4A
T5

Electrical Ratings:
• Power supply –
Input: 120, 220, 230, 240, or 277 VAC,
50 or 60 Hz; 9 watts max.
Output: 18 watts max. at 12 VDC
• Luminaire heads –
Voltage: 12 VDC; Lamp: 3 watt LED
Total lumen output: 80

Unit Net Weights:
•
•
•
•

N2LPS12222 – 16 lbs.
N2LPS12220 – 12 lbs.
N2RF1221 – 8 lbs.
N2RF1222 – 9 lbs.

Options:
Description
Suffix
55°C suitability . . . . . . . . . . . . . . . . .S904

2L

• Compact, factory-assembled luminaire
featuring LED lamps for improved lumen
performance, on-time, and lamp life
• Nonmetallic, enclosed, and gasketed
housing provides corrosion protection in
the most extreme environments
• Durable and marine rated LED lamp
head assemblies provide protection
against water ingress, corrosion, and
impact
• High temperature rated nickel cadmium
battery for reliable operation up to 55ºC
ambient
• Solid state battery charger for long life
and reliable battery operation prevents
deep discharge by automatically
disconnecting the battery from the
luminaire
• Factory-installed "push-to-test" button
• Self-test, monitoring, and diagnostics
reduce costly maintenance checks
• Remote luminaire head assemblies
(one or two) are available for mounting of
luminaire heads away from main power
system
• Stainless steel drain minimizes moisture
collection
• Standard battery disconnect switch
(Krydon® unit)

2L

Class II,
Division 1
T6
T6

Ambient temperature at which the Light-Pak
system is rated is 0°C to 55°C. Operation at
temperatures outside this range will affect the
battery life and/or charging performance.

Note: Battery time in emergency mode is 90 minutes.
National Electrical Code and Life Safety Code are
registered trademarks of the National Fire Protection
Association, Inc.
Noryl is a registered trademark of General Electric
Company.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

937

938-939.qxp

12/16/2013

7:09 PM

Page 938

N2LPS LIGHT-PAK™
Emergency Lighting System

2L

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 2
Cl. II, Div. 2, Groups F, G
Wet Locations, Marine
NEMA 3, 3R, 4X
Ambient 0ºC to 55ºC

Ordering Information:
Description

Cat. #

28 watt, 12 volt power supply assembly with two 3 watt LED lamp heads
28 watt, 12 volt stainless steel power supply assembly with two 3 watt LED lamp heads
28 watt, 12 volt power supply assembly less luminaire heads
Remote luminaire assembly with one 3 watt LED lamp head
Remote luminaire assembly with two 3 watt LED lamp heads
28 watt, 120V LED Light-Pak with single sided exit sign**
28 watt, 277V LED Light-Pak with single sided exit sign**
28 watt, 120V LED Light-Pak with double sided exit sign**
28 watt, 277V LED Light-Pak with double sided exit sign**

N2LPS12222
N2LPS12222 SS
N2LPS12220*
N2RF1221*
N2RF1222*
N2LPS12222/120
N2LPS12222/277
N2LPS12222/120
N2LPS12222/277

EXS DR0391734
EXS DR0391734
EXD DR0391734
EXD DR0391734

*Not cUL approved. UL Listed only.
**Exit sign operates in both normal and emergency mode.

Note: Up to four (4) remote LED lamp assemblies can be connected to the N2LPS12222. Up to six (6) remote LED lamp assemblies can be
connected to the N2LPS12220.

Wire Sizing for Remote Installation:
For Copper Wire –
Running Distance† (ft.) Between Power Supply and Remote Luminaire
Load In Watts
Wire Size
8
16
24
32
Wire Size

Load In Watts
8
16

24

32

16 AWG
14 AWG
12 AWG

106
168
270

26
42
67

13
21
33

26
42
66

13
21
33

6
10
16

3
5
8

10 AWG
8 AWG
6 AWG

53
84
135

†Maximum distance to limit line voltage drop to 5%.

Dimensions (N2LPS):
1.1

2L

13.5

16.0

7.5
5.0

13.8
14.5

7.4

18.0
Standard – N2LPS LED Light-Pak™

938

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

938-939.qxp

12/16/2013

7:09 PM

Page 939

N2LPS LIGHT-PAK™
Emergency Lighting System

2L

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 2
Cl. II, Div. 2, Groups F, G
Wet Locations, Marine
NEMA 3, 3R, 4X
Ambient 0ºC to 55ºC

Dimensions (N2LPS):

EXS, EXD Option – N2LPS LED Light-Pak™ with Optional Emergency Exit Luminaire

Dimensions (N2RF):

9.50
9.50

2L

3.83

3.83

7.27

4.38

11.77

Detail Indication Logic:
Status Indication
*
*-*
**-**
***-***

Status Description
No Light
Steady Light (No Blinks)
Light Blinks Once
Light Blinks Twice
Light Blinks Three Times

www.crouse-hinds.com

Status Definition
AC Power Removed from Circuit
Fully Charged
Battery Charging
Battery Failure
Circuit Failure

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

939

940-941.qxp

12/16/2013

2L

7:11 PM

Page 940

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, AEx em ib IIC (NEC)
Cl. I, Zone 1, Ex em ib IIC (CEC)
Cl. II, Div. 2, Groups F, G (NEC)
Cl. II, Div. 2, Groups E, F, G (CEC)

Ex-Lite LED Exit Signs

UL Listed
IP66

The Ex-Lite Series of LED exit signs are
designed for hazardous locations and are
ideally suited for marking escape routes
and exits in potentially explosive
atmospheres.
The Ex-Lite Z is available as an AC only
version, while the Ex-Lite ZE is available
with self-contained battery. As an
emergency lighting luminaire with selfcontained battery system, the Ex-Lite ZE
features a nickel cadmium battery with
automatic test and monitoring feature.

Applications:
• In harsh and hazardous environments
where illuminated exit signs are required

2L

Features and Benefits:
LED Technology:
• Long life (>50K hours) for years of
maintenance-free operation
• Energy-efficient for lower cost of
operation
• Low temperature operation with no loss
of illumination
• Rugged and durable light source for the
harshest of environments
Exit Sign System:
• Can be used in a hazardous location
• Conduit or cable entry
• Can be installed in moist, humid, rain,
and wet environments
• Universal input voltage 110VAC-277VAC
and 110VDC-250VDC reduces inventory
• Ex-Lite ZE with self-monitoring, selfdiagnostic, and test capability
• Premium heavy-duty nickel cadmium
battery
• 24-hour charge and recharge time
increases safety by recovering quickly
from outage
• "EXIT" legend with alternative wings left, right, or left and right; simple field
modification
• Emergency lighting cycle three hours
• The housing of the luminaire is
constructed with a corrosion resistant,
robust, lightweight aluminum alloy
material and illumination of the sign is
provided with red, high-efficient LEDs

Ordering Information:
Catalog Number

Ex Lite Z

Ex Lite ZE

Material Number
Description
Light Source
Life of LED
Rated Voltage, VAC
Frequency, Hz
Rated Voltage, DC
Power Consumption
Battery

12191001005
AC/DC Exit Sign
LED
50K hours
120V-277V
50/60
110V-250V
6VA
N/A

12191130005
with Battery
LED
50K hours
120V-277V
50/60
110V-250V
6VA
NiCad

Allowable Temperature Range

-4ºF to 122ºF
(-20ºC to 50ºC)

41ºF to 95ºF
(5ºC to 35ºC)*

Mounting
Cable Entry
Conduit Entry
Protection

Wall
Ex-e
3
/4”
IP66

Wall
Ex-e
3
/4”
IP66

*Due to battery chemistry, the charging capacity will be limited at temperatures below 5ºC and above 35ºC.

Dimensions
In Inches (mm):

Certifications and
Compliances:
•
•
•
•
•
•
•
•
•
•

Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, AEx em ib IIC (NEC)
Class I, Zone 1, Ex em ib IIC (CEC)
Class II, Division 2, Groups F, G (NEC)
Class II, Division 2, Groups E, F, G (CEC)
IP66
UL844
UL924/CSA22.2 No. 141-02
UL60079/CSA22.2 E60079
UL1203/CSA22.2 E6124-1-1-02

940

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

940-941.qxp

12/16/2013

7:11 PM

Page 941

CCH UX Series
LED Exit Signs

2L

NEMA 4X, IP66

UL Listed
Available with Cl. I, Div. 2,
Groups A, B, C, D rating

Eaton's Crouse-Hinds CCH UX Series LED Exit Sign combines the
strength and durability of die cast aluminum with architecturallypleasing aesthetics. The CCH UX Series is illuminated by LEDs,
providing the customer with a long-life, low maintenance,
dependable exit sign for use in conditions where reliability is crucial.
Designed for the most severe environments, the CCH UX Series will
provide maximum performance against rain, moisture, cold,
corrosion, and dust in applications such as manufacturing plants,
refineries, petrochemical and chemical plants, waste and sewage
treatment facilities, food processing, and other industrial facilities.

Applications:
• In locations deemed hazardous due to the presence of flammable
vapors or gases
• In areas where the presence of gases or vapors may become
present during an abnormal, unusual, or accidental conditions
• Outdoor and wet applications
• Where required by the National Electrical Code®, Life Safety
Code®, or other applicable codes

Features and Benefits:

NEMA 4X, UL50
UL924 wet location
IP65, IP66
Available with NEC hazardous location rating
- UL844 Class I, Division 2, Groups A, B, C, D

CCH UX Series Exit Sign:
• -45ºC (-49ºF) to 45ºC (113ºF)
CCH UX-HAZ Hazardous Location Exit Sign:
• T6 rating at 45ºC (113ºF)

Electrical Ratings:
• Power Supply
120V/277V dual voltage
• LED Exits - Red
Input Power
120V = 2.7W
277V = 3.2W

• LED Exits - Green
Input Power
120V = 2.3W
277V = 3.0W
Input Current:
(Max.)
120V = .08A
277V = .03A

Ordering Information:

Dimensions
In Inches:

Mounting: wall mount, ceiling mount, end mount
Conduit Entry: top, bottom, or either side of the unit

www.crouse-hinds.com

Temperature Performance Data:

Input Current:
(Max.)
120V = .07A
277V = .04A

Certifications and Compliances:
•
•
•
•

• Provides safe and reliable exit marking both indoors and outdoors
during power failure or interruption of power to normal lighting
system
• Long life (>50K hours) for years of maintenance-free operation
• Energy-efficient for lower cost of operation
• Low temperature operation with no loss of illumination
• Rugged and durable light source for the harshest of environments

2L

• Wet location, outdoor rated for use in the most demanding
environments
• Optional hazardous location rating available
• Dual voltage 120V/277V reduces wiring errors
• Heavy-duty nickel cadmium battery for long life
• 24-hour charge and recharge recovery time increases safety
• Heavy-duty injection molded polycarbonate lens protects against
impact and corrosion
• Brown-out protection protects battery and reduces labor
• Heavy-duty aluminum die cast housing protects against impact
and chemical resistance
• LEDs provide long life, even illumination, and energy savings
• Wide operating temperature range (-45°C to 45°C)
• Self-diagnostic testing reduces costs by eliminating scheduled
equipment verification tests
• Heavy duty nickel cadmium battery for long life meets 90 minute
requirements for battery operated emergency system

Benefits of LED Technology:

US: 1-866-764-5454

Catalog Number

Housing Finish

Letter Color

CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH

Silver Housing
Silver Housing
Silver Housing
Silver Housing
Silver Housing
White Housing
Black Housing
Silver Housing
White Housing
Black Housing
Silver Housing
White Housing
Black Housing
Silver Housing
White Housing
Black Housing

Red LED
Red LED
Green LED
Green LED
Red LED
Red LED
Red LED
Red LED
Red LED
Red LED
Green LED
Green LED
Green LED
Green LED
Green LED
Green LED

UX70RSDHAZ
UX60RHAZ
UX70GSDHAZ
UX60GHAZ
UX70RSD
UX70RWHSD
UX70RBKSD
UX60R
UX60RWH
UX60RBK
UX70GSD
UX70GWHSD
UX70GBKSD
UX60G
UX60GWH
UX60GBK

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

941

942-943.qxp

12/16/2013

7:13 PM

Page 942

Pro Series Industrial
LED Luminaires

2L

The robust Pro Series LED family allows
for replacement of existing HID,
floodlights, and incandescent industrial
fixtures, and provides an energy-efficient,
proven light source for use in applications
where reliability is crucial.

PRO SERIES LED BENEFITS

B

A Customized heat sinks
Eaton’s Crouse-Hinds’ heat sinks are specifically
engineered to remove heat from the LEDs and driver
to ensure longer life, better lumen output, and
accurate color temperature.

A

Applications:

B Retrofittable mounting modules

• Robust Pro Series LED family allows for
replacement of existing HID, floodlights,
and incandescent industrial fixtures
• Locations requiring continuous and
consistent light levels in extreme
ambient temperatures
• Areas requiring frequent on-and-off of
lights
• Areas that are difficult to relamp or that
cause production to be stopped during
the lamp maintenance process
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist
• Type 4X, marine, wet locations and
hose-down environments
• Warehouses, outdoor areas, production
facilities, etc.

Compact modular fixtures attach to existing Eaton’s
Crouse-Hinds installed mounting modules, reducing
installation costs.

C

C Long life LEDs eliminate maintenance cost
Eaton’s Crouse-Hinds’ luminaires remove the high
maintenance costs associated with traditional
lamps.

2L

Product Selector Chart:

Series

Champ® Pro PVM Series
UL1598; UL1598A; cUL; Type 4X;
IP66; CE

Champ® Pro PFM Series
UL1598; UL1598A; cUL; NEMA 4X;
IP66

Vaporgard™ Pro P2L Series
UL1598; UL1598A; cUL; NEMA 4X;
IP66

Applications / Uses

• General high bay/low bay
illumination

• Outdoor/indoor flood illumination

• Low mounting heights, such as
stairways, walkways, and
doorways
• Targeted illumination

Equivalent Output

Replaces 70W to 400W HID

Replaces 70W to 400W HID

Replaces up to 200W incandescent

Mounting Styles

Wall; Ceiling; Pendant; Flexible
Pendant; Cone Pendant; Stanchion

Yoke Mounted

Wall; Ceiling; Pendant; Stanchion

Photometrics and
Test Reports Available

• IES Photometric Files
• LM-80 Lumen Maintenance
Report
• LM-79 Test Report

• IES Photometric Files
• LM-80 Lumen Maintenance Report
• LM-79 Test Report

• IES Photometric Files
• LM-80 Lumen Maintenance
Report
• LM-79 Test Report

Certifications

942

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

942-943.qxp

12/16/2013

7:13 PM

Page 943

Champ® Pro PVM Series
Luminaires

2L

UL/cUL Listed
Type 4X
IP66

Ideal for general high bay/low bay illumination
The Champ® Pro PVM Family
Champ® Pro PVM Series Luminaires are designed to provide full-spectrum, crisp, white light
with custom IES Type I, III, and V distribution. Five versions of the PVM Series are available,
providing ideal solutions for a wide range of applications.
Model

Nominal† Lumens
(Type V)
Wattage

Equivalent HID
Luminaire

Typical Energy
Savings / Lifetime

PVM3L
PVM5L
PVM7L
PVM9L
PVM11L

3,515
5,288
7,404
9,515
10,935

70W-100W
100W-150W
150W-175W
250W-400W
400W

Up
Up
Up
Up
Up

41
67
94
114
118

to
to
to
to
to

77%
67%
67%
74%
74%

†Tolerance +/- 10%.

Applications:
• Locations requiring continuous and
consistent light levels in extreme ambient
temperatures
• Areas requiring frequent on-and-off of lights
• Where extremely corrosive, wet, dusty, hot
and/or cold conditions exist
• Manufacturing plants; heavy industrial,
chemical, petrochemical, or
pharmaceutical facilities; food and
beverage facilities; mining; platforms;
loading docks; tunnels; indoor/outdoor
spot lighting; outdoor wall and stanchion
mounted general area lighting

Certifications and
Compliances:

Custom Optics:

*Cool white 120-277 VAC 3L-11L models. Refer to page 2
of the D-0413 authorized distributor price book for Eaton's
Crouse-Hinds standard Terms and Conditions.

• Instant illumination and restrike
• Better visibility with crisp, white light
• Cold temperature operation / no warmup required
• Redundancy in drivers with multiple
series circuits connected to each driver
to avoid complete loss of illumination
• Easy installation - compact modular
fixture attaches onto existing Champ®
mounting module
• Energy-efficient technology - up to 77%
energy savings over HID fixtures
• Provides up to 60,000 hours rated life
and up to 170,000 hours of economic
life - eliminates need for frequent lamp
replacement
• Contains no mercury or other hazardous
substances
• Shock- and vibration-resistant solid-state
luminaires have no filaments or glass
components that could break - greatly
reduces the risk of premature failure
• Operating ambient -40°C to 55°C
• Dark sky compliant
• 5 year fixture warranty††

LED System:

TYPE I
Ideal for:
• Mining conveyor belts
• Aisleways and hallways
• Catwalks and walkways
• Ramps and loading docks
• Tunnels with overhead
mounts
TYPE III
Ideal for:
• Narrow crosswalks or
passages with wall
mounted fixtures
• Tunnels with wall mount
• Wall or stanchion mount
requiring 180° forward
throw beam patterns

• High intensity discrete power emitters
• Cool white (5000K, 70 CRI) and warm
white (3000K, 80 CRI)
• Custom optics designed to go over each
discrete LED

TYPE V
Ideal for:
• Pendant, ceiling or
stanchion mount overhead
building mounts
• Processing mills, industrial
plants, large buildings,
warehouses, etc.

Standard Materials:
• Lamp housing and adapter – die cast
aluminum with Corro-free™ epoxy
powder coat
• Lens – heat- and impact-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals required

2L

Champ Pro PVM LED
Benefits:

††Refer to page 2 of the D-0413 authorized distributor
price book for Eaton's Crouse-Hinds standard Terms and
Conditions.

Three optical options to maximize light
distribution and intensity:

• DesignLights Consortium® for select
models* (pending)
NEC and CEC
• Wet Locations, Type 4X, IP66
UL Standards
• UL1598 Luminaires, UL1598A Marine
CSA Standard
• cUL Listed to CSA Standard CSA C22.2
No. 250
IEC Standard
• CE

Drivers:
Option

3L - 11L

/UNV1
/UNV34**
/VDC‡

120-277 VAC, 50 / 60 Hz
347-480 VAC, 50 / 60 Hz
108-250 VDC, 50 / 60 Hz

**No separate external transformer required to step
down voltage.
‡Separate driver for DC applications.

Electrical Ratings:
PVM3L

PVM5L

PVM7L

PVM9L

PVM11L

Voltage Range, VAC

120-277

120-277

120-277

120-277

120-277

Frequency

50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz

Input Power (Watts)

41

67

94

114

Input Amps at 120-277 VAC

0.34-0.17

0.57-0.29

0.80-0.42

0.96-0.49

0.96-0.49

Voltage Range, VDC

108-250

108-250

108-250

108-250

108-250

Power Factor

>0.90

>0.90

>0.90

>0.90

>0.90

Nominal Lumens† (Type V)

3,515

5,288

7,404

9,515

10,935

118

†Tolerance +/- 10%.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

943

944-945.qxp

12/16/2013

7:14 PM

Page 944

Champ® Pro PVM Series
Luminaires

2L

UL/cUL Listed
Type 4X
IP66

Ideal for general high bay/low bay illumination
Design Features:

A

A Installation and replacement made simple - this contractor-friendly,

modular design is ideal for both retrofit and new construction
applications. These luminaires are installed in the same manner
and use the same mounting modules as existing Champ® Series
luminaires. The compact modular design of the PVML allows for
easy component replacement and future upgrade.
B High efficiency and lumen output - custom high efficiency LED
drivers are designed to provide reliable operation in even the
harshest environments. Various AC and DC input voltage options
are available to suit virtually any drive requirement.
C Safe, reliable heat transfer - die cast aluminum housing provides
safe and effective heat transfer from the LED assembly to the
outside environment, ensuring low LED junction temperature,
reliability, and sustained lumen performance. The vertical fin
design facilitates air flow and dust shedding. The impact-resistant
lens is sealed from the outside environment and provides ingress
protection against water and dust.
D Custom optics - custom optics designed for discrete LED
power emitters.
E Ease of wiring and installation - available with lever lock
connectors and standard three-pole terminal block for ease of
wiring and installation.

E
B

C

D

Custom Optics:
Custom optics designed for discrete LED power emitters:
• Type V standard
• Type I and Type III optional

Colored LED Options:
Available in red, blue, green and amber
Reduction in light pollution for night space observation and sky glow due to isolating blue wavelength in red and amber colors
Wildlife friendly
Improves visibility for telescopes in observatories during night sky space exploration

2L

•
•
•
•

Type I

Type III

Type V

Options:
Description
Wire guard with captive mounting hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trunnion mount with redundant pin locking mechanism (ceiling mount required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Clip for quick installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diffused lens for glare reduction‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Teflon coating on lens for additional shatter protection‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Polycarbonate lens available in applications where glass is prohibited . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Six-pole terminal block‡‡ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Suffix
P3001
S812 K1
S890
S891
S896
S903
TB6

‡‡Not available for IEC applications.

Accessories (Ordered Separately):
Description
Photocell, 120V, 50 / 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Photocell, 208-277V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Occupancy sensor, 1/ 2" entry, 120/ 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Occupancy sensor, 3/ 4" entry, 120/ 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Occupancy sensor, 1" entry, 120/ 277 VAC*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
***For 347-480 VAC, replace /UNV1 with /UNV34.

944

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Cat. # (Ordered Separately)
D2S20
D2S208 277
COS1/UNV1
COS2/UNV1
COS3/UNV1

944-945.qxp

12/16/2013

7:14 PM

Page 945

Champ® Pro PVM Series
Luminaires

2L

UL/cUL Listed
Type 4X
IP66

Ideal for general high bay/low bay illumination
Catalog Numbering System:

PVM 7L W 2A R1 G /UNV1 S890
Lamp/Function
3L

3,515 Lumen LED

5L

5,288 Lumen LED

7L

7,404 Lumen LED

9L

9,519 Lumen LED

11L

10,935 Lumen LED

RL

Red (3,200 Lumen)

/UNV1

GL

Green (4,300 Lumen)

BL

Blue (2,100 Lumen)

AL

Amber (5,000 Lumen)

Color Temperature
BLANK

Suffixes

Guard

Cool

BLANK

No Guard

S812

Trunnion Mount Kit with Pin

(5000 ± 200K)

G

P3001 Wire Guard

S890

Quick Clip

S891

Diffused Lens†

S896

Teflon Coated Lens†

120-277 VAC, 50/60 Hz

S903

Polycarbonate Lens

/UNV34

347-480 VAC, 50/60 Hz

TB6

Six-pole Terminal Block†

/VDC

108-250 VDC, 50/60 Hz

Warm

W

Voltage

(3000K ± 200K)

Mounting Style
BLANK

No Cover

J

1-½” Stanchion 25°

P

1-½” Stanchion Straight

2A

¾” Pendant

3A

1” Pendant

2B

¾” Cone Pendant

3B
2C
3C
2HA

Optics

1” Cone Pendant
¾” Ceiling
1” Ceiling
¾” Flexible Pendant

2TW

¾” Wall

3TW

1” Wall

BLANK

Type V Optic Standard (All Mounts)

R1

Type I Optic (All Mounts Minus Ceiling)

R1A

Type I Optic (Ceiling with Conduit 45° Counterclockwise or 135° Clockwise from Hinge)*

R1B

Type I Optic (Ceiling with Conduit 45° Clockwise or 135° Counterclockwise from Hinge)*

R3

Type III Optic (All Mounts Minus Ceiling)

R3A1

Type III Optic (Ceiling with Conduit 45° Counterclockwise from Top Hat Hinge)**

R3A2

Type III Optic (Ceiling with Conduit 135° Clockwise from Top Hat Hinge)**

R3B1

Type III Optic (Ceiling with Conduit 45° Clockwise from Top Hat Hinge)**

R3B2

Type III Optic (Ceiling with Conduit 135° Counterclockwise from Top Hat Hinge)**

*For new construction, order R1A only.
**For new construction, order R3A1 only.
†Not available for IEC applications.

Dimensions:
Pendant

Ceiling

Wall

Trunnion

354.6
13.96

50.8
2.00

295.2
11.62

BRACKET FOR WALL MOUNT
OR SFA6 SLIPFITTER

118.6
4.67

258.6
10.18

295.1
11.62

Cone Pendant

300.4
11.83

71.2
2.80

2X LOCKING PINS

2X TRUNNION ROTATION
HARDWARE

117.5
4.63

51.6
2.03

279.4
11.00

158
6.22

CM2 OR CM3
TOP HAT

287.3
11.31

280.1
11.03

2L

273.5
10.77

386.6
15.22
2X TOP HAT MOUNTING
HARDWARE

225.6
8.88

Stanchion Angled

Stanchion Straight
407.2
16.03

Weights:
382.7
15.07

88.7
3.49

273.8 45.2
10.78 1.78

53.4
2.10
326.3
12.85

282
11.10
25°

247.7
9.75

www.crouse-hinds.com

Net Luminaire Weight:

21.8 lbs.

8.07 kg.

Mounting Module add (lb.)
Pendant
Cone Pendant
Flexible Pendant
Ceiling
Wall
Angle Stanchion
Straight Stanchion

1.25
4.00
1.50
2.75
4.50
3.50
4.50

0.57
1.81
0.68
1.25
2.04
1.59
2.04

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

945

946-947.qxp

12/16/2013

7:14 PM

Page 946

Champ® Pro PVM Series
Luminaires

2L

UL/cUL Listed
Type 4X
IP66

Ideal for general high bay/low bay illumination
Family Tree:
MOUNTING MODULE SERIES
ANGLED
BPM2
BPM3

PENDANT
APM2
APM3
HPM2

CEILING
CM2
CM3

STANCHION
PM5
JM5

WALL
TWM2
TWM3

VMV*L
PVM*L

Photometric Data:
Photometric Layout Comparison - Champ® PVM7L LED Versus 175W Metal Halide:
PVM7L - Type I

VMV 175W PSMH - Type I
50

50

40

30

20

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.3

0.3

0.4

0.4

0.4

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.6

0.6

0.6

0.7

0.7

0.6

0.6

0.6

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.4

0.1

0.2

0.3

0.2

0.2

0.3

0.2

0.3

0.4

0.5

0.6

0.4

.5
0.5

0.7

1.0

1.5

0.1

10

0

0.6

0.5

1.75

40

30

20

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.1

0.0

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.8

0.7

0.7

0.8

0.7

0.8

0.9

0.9

0.9

0.9

0.9

0.9

0.8

0.6

0.4

0.3

0.2

0.1

0.1

0.2

0.3

0.4

0.4

0.4

0.2

0.2

0.4

0.5

0.4

0.3

0.3

0.2

0.7

1.0

1.1

1.1

1.4

1.4

1.1

1.1

1.0

0.7

0.5

0.3

0.2

0.2

0.1

0.2

0.3

0.5

0.6

0.8

1.0

1.0

0.6

1.0

1.0

0.8

0.7

0.5

0.4

0.3

0.9

1.1

1.3

2.1

2.6

2.6

2.1

1.3

1.1

0.9

0.6

0.5

0.4

0.3

0.2

0.3

0.5

0.7

0.9

1.2

1.7

2.4

2.7

3.0

3.2

3.3

3.0

2.7

2.4

1.8

1.3

1.0

0.7

0.5

0.4

2.0

2.1

2.1

3.0

2.9

2.9

3.0

2.1

2.1

2.0

1.5

1.0

0.7

0.5

0.4

0.4.5

0.6

0.9

1.2

1.75
1.7

2.4

3.5

4.8

6.3

7.3

7.2

6.3

4.7

3.4

2.5

1.7

1.3

0.9

0.7

0.5

6.3

4.7

3.4

2.5

1.7

1.3

0.9

0.7

0.5

10

0

-10

-20

-30

-40

-50

.5
0.5

.75
0.7

11.0

1.5
1.5

22.0

2.1

0.2

0.3

0.4

0.5

0.6

0.9

1.1

1.2

1.9

0.1

0.2

0.2

0.3

0.5

0.7

1.0

1.1

1.0

0.1

0.1

0.2

0.3

0.4

0.6

0.8

0.8

0.8

0.1

0.1

0.2

0.2

0.3

0.5

0.5

0.6

0.6

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.4

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

2.1

2.9

2.6

2.6

2.9

2.4

2.4

1.3

1.3

0.8

0.6

0.4

0.2

2.0

1.5

2.1

2.1

1.0

0.7

0.5

1.9

1.2

1.1

0.9

0.6

0.5

0.4

0.3

0.2

1.0

1.1

1.0

0.7

0.5

0.3

0.2

0.2

0.1

0.8

0.8

0.8

0.8

0.6

0.4

0.3

0.2

0.1

0.1

0.6

0.6

0.6

0.5

0.5

0.3

0.2

0.2

0.1

0.1

0.4

0.4

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.3

0.3

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.4.5

0.4

-10

-20

-30

-40

-50

0.6

.75

0.9 1

1.2

1.5

1.7 2

2.4

3.5 4

3

5
4.8

-40

-30

-20

-10

0

6

7

6.3

7.3

0.5

0.7

0.9

1.2

1.7

2.4

2.7

3.0

3.2

3.3

3.0

2.7

2.4

1.8

1.3

1.0

0.7

0.5

0.4

0.2

0.3

0.5

0.6

0.8

1.0

1.0

0.6

0.8

0.7

0.7

0.8

0.7

1.0

1.0

0.8

0.7

0.5

0.4

0.3

0.2

0.2

0.3

0.4

0.4

0.4

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.4

0.5

0.4

0.3

0.3

0.2

0.1

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

10

20

30

40

50

0.0

-50

-40

-30

-20

-10

0

10

20

30

40

0.75

1

1.25

1.5

2

4

3

5

7

Label

Calc. Type (in Fc)

Avg.

Max.

Min.

VMV 175W MH Grid

Illuminance

0.49

3.0

0.0

PVM LED Grid

Illuminance

0.58

7.3

0.0

50

Distance In Feet

PVM7L - Type III

VMV 175W PSMH - Type III
50

50
0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.2

0.2

0.3

0.3

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.3

0.3

0.4

0.4

0.4

0.4

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.4

0.4

0.4

0.4

20

0.5

0.6

0.7

0.7

0.6

0.4

0.5

0.6

0.6

0.7

0.7

0.6

0.6

0.5

0.4

0.6

0.7

0.7

0.6

0.5

1.1

10

0.5

2.1

40

30

0.8

1.0

1.1

0.7

0.8

0.7

11.0

1.5

1.8

1.2

0.5

0.8

1.2

1.72

2.6

2.9

2.0

0.3

0.5

0.7

1.0

1.5

2.0

2.0

0.2

0.2

0.3

0.4

0.6

0.9

1.3

1.6

0.2

0.2

0.3

0.4

0.5

0.8

1.0

0.1

0.2

0.3

0.4

0.5

0.7

0.1

0.2

0.2

0.3

0.4

0.6

0.1

0.2

0.2

0.3

0.3

0.4

0.1

0.1

0.2

0.2

0.3

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.6

0.4

0

.25
0.2

.5

1.2

1.9

1.5

2.5

4

0.8

0.9

0.9

0.8

0.8

0.7

1.1

1.1

1.1

1.1

1.2

1.8

2.4

3.3

3.3

2.4

2.0

2.9

4.5

3.7

3.7

4.5

2.0

2.0

1.1

1.2

1.1

2.1

1.9

1.5

1.0

0.7

0.5

2.6

1.7

1.2

0.8

0.5

0.4

1.5

1.0

0.7

0.5

0.3

0.2

1.0

0.8

40

30

20

0.6

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.5

0.6

0.6

0.6

0.6

0.5

0.4

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.5

0.7

0.9

1.1

1.2

1.2

1.1

0.9

0.7

0.5

0.4

0.3

0.2

0.2

0.1

1.1

1.5

2.0

0.2

0.2

0.2

10

0

0.4

0.5

0.7

0.2

0.2

0.3

0.5

0.7

1.0

0.2

0.3

0.4

0.5

0.8

1.3

0.2

0.3

0.2

0.4

0.3

0.6

0.9

1.4

2

0.2

.25
0.3

0.4

0.5

0.8

1.2

1.5

0.2

0.2

0.3

0.4

0.6

0.8

0.1

0.2

0.2

0.3

0.4

0.1

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

1.6

2.6

2.1

3.5

2.3 3

3.9

2.0

5.4

6.2

1.5

1.1

0.7

0.5

0.4

0.3

4.3

4.3

3.5

2.6

1.6

1.0

0.7

0.5

0.3

6.4

6.4

5.4

3.5

2.1

1.3

0.8

0.5

0.4

0.3

0.2

7.6

7.6

6.2

3.9

2.3

1.4

0.9

0.6

0.4

0.3

0.2

2.4

6

-10

-20

-30

-40

-50

2.8

2.8

3.8

1.6

1.3

0.9

0.6

0.4

0.3

0.2

0.2

1.2

1.5

2.9

2.9

1.5

1.2

1.0

0.8

0.5

0.4

0.3

0.2

0.2

0.9

1.0

1.1

1.2

1.2

1.1

1.0

0.9

0.7

0.5

0.4

0.3

0.2

0.1

0.7

0.9

0.9

0.9

0.9

0.9

0.9

0.7

0.6

0.4

0.3

0.2

0.2

0.1

0.5

0.6

0.7

0.7

0.7

0.7

0.6

0.5

0.4

0.3

0.3

0.2

0.2

0.1

0.3

0.4

0.4

0.4

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

-10

-20

-30

-40

-50

.5

-40

-30

-20

-10

0

0.2

2.9

4.6

5.9

5.9

4.6

2.9

1.8

1.2

0.8

0.5

0.4

0.3

0.2

1.0

1.4

2.2

4.0

4.0

2.2

1.4

1.0

0.8

0.6

0.4

0.3

0.2

0.2

0.4

0.5

0.5

0.9

1.3

1.3

0.9

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.1

0.2

0.2

0.3

0.5

0.6

0.6

0.5

0.3

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.3

0.3

0.3

0.3

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

1

1.8

2.5

Point By Point Foot-Candles

-50

0.2

TYPE III OPTICAL PATTERN

0.25

coo173140

3.8

3

2.4

4

3.5

5

VMVM2C175G243-S828

10

20

30

40

50

-50

-40

-30

-20

-10

0

10

20

30

40

0.5

1

1.5

2.5

2

4

3

5

6

Calculation Summary

Point By Point Foot-Candles

Distance In Feet

Label

Calc. Type (in Fc)

Avg.

Max.

Min.

VMV 175W MH Grid

Illuminance

0.59

4.5

0.1

PVM LED Grid

Illuminance

0.61

7.6

0.0

50

Distance In Feet

VMV 175W PSMH - Type V

PVM7L - Type V

50

50
0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.4

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.5

0.6

0.7

0.7

0.7

0.7

0.6

0.5

0.3

0.3

0.2

0.2

0.1

0.1

20

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.8

0.9

1.0

1.0

0.9

0.8

0.7

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.9

1.1

1.2

1.3

1.3

1.2

10

0.1

0.2

0.2

0.4

0.6

0.8

1.1

1.3

1.4

1.7

1.7

1.4

1.3

1.1

0.8

0.6

0.4

0.2

0.2

0.1

0.1

0.2

0.3

0.4

0.7

0.9

1.2

1.4

2.2

2.8

2.8

2.2

1.4

1.2

0.9

0.7

0.4

0.3

0.2

0.1

0.1

0.2

0.3

0.5

0.7

1.0

1.3

1.75
1.7

2.8

2.6

2.6

2.8

1.7

1.3

1.0

0.7

0.5

0.3

0.2

0.1

0.1

0.2

0.3

0.5

0.7

11.0

1.3

1.7

2.8

2.6

2.6

2.8

1.7

1.3

1.0

0.7

0.5

0.3

0.2

0.1

0.1

0.2

0.3

0.4

0.7

0.9

1.2

2.2

2.8

2.8

2.2

1.4

1.2

0.9

0.7

0.4

0.3

0.2

0.1

0.1

0.2

0.2

0.4

0.6

.75 0.8

1.1

1.3

1.4

1.7

1.7

1.4

1.3

1.1

0.8

0.6

0.4

0.2

0.2

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.9

1.1

1.2

1.3

1.3

1.2

1.1

0.9

0.7

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.7

0.8

0.9

1.0

1.0

0.9

0.8

0.7

0.5

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.5

0.6

0.7

0.7

0.7

0.7

0.6

0.5

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.4

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

40

30

0

1.1

0.9

0.7

0.5

0.3

0.2

0.2

40

30

20

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.2

0.3

0.3

0.2

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.2

0.5

0.8

1.1

1.1

0.9

0.6

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.6

1.3

2.3

0.0

0.0

0.0

0.0

0.1

1.5

0.8

0.2

4.9

4.1

2.8

1.6

0.6

2.0

3.9

5.8

7.2

7.2

6.1

4.2

2.3

1.0

0.3

0.1

0.0

0.0

0.0

1.0

1.75

2.5

4.8

7
7.1

6.5

6.4

7.3

5
5.1

2.8

1.3

0.4

0.1

0.0

0.0

0.0

1
1.0

2

2.5

7.1

6.5

6.4

7.3

5.1

2.8

1.3

0.4

0.1

0.0

0.0

0.0

0.8

1.5

2.0

5.8

7.2

7.2

6.1

4.2

2.3

1.0

0.3

0.1

0.0

0.0

0.0

1.6

0.6

0.2

0.1

0.2

1.3

4.9

-10

-20

-30

-40

-50

.5

1.5

1.4

2

-40

-30

-20

-10

0

3L

0.2

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.2

0.1

0.3

0.0

0.0

0.0

0.1

0.3

-10

0.0

0.0

0.0

0.1

0.2

0.0

0.0

0.0

0.1

0.1

0.4

1.3

2.6

-20

0.0

0.0

0.0

0.0

0.1

0.2

0.6

1.3

2.1

2.6

2.6

2.3

1.5

0.8

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.2

0.5

0.8

1.1

1.1

0.9

0.6

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.2

0.3

0.3

0.2

0.2

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

TYPE V OPTICAL PATTERN

0.5

7L Type V

-30

-40

-50

.5

4

3

4.8

3.9

10

6

3.9

4.9

4.9

4.1

2.8

0.0

0.0

20

30

40

50

-50

-40

-30

-20

-10

0

10

20

30

40

0.75

1

1.5

1.75

2

3

4

5

Label

Calc. Type (in Fc)

Avg.

Max.

Min.

VMV 175W MH Grid

Illuminance

0.51

2.8

0.1

PVM LED Grid

Illuminance

0.69

7.3

0.0

50

Distance In Feet

5L

7L

9L

11L

Type I

3,115

4,687

6,562

8,437

9,692

Type III

3,271

4,921

6,890

8,859

10,177

Type V

3,515

5,288

7,404

9,519

10,935

†Tolerance +/- 10%.

www.crouse-hinds.com

US: 1-866-764-5454

6

Calculation Summary

0.0

Point By Point Foot-Candles

Distance In Feet

Actual Lumens
(Nominal†)

0.1

0.1

0.1

0.0

Point By Point Foot-Candles

-50

0.1

0.1

0.0

0.0

0.8

3.9

2.6

0.0

0.0

0.0

.75

2.6

2.6

0.0

0.0

0

0.4

2.1

0.0

10

VMVM2C175G245-S828

946

6

Calculation Summary

Point By Point Foot-Candles

Distance In Feet

2L

7.2

0.3

Point By Point Foot-Candles

-50

0.25

7L Type I

VMVM2C175G241-S828

0.4

TYPE I OPTICAL PATTERN

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

7

946-947.qxp

12/16/2013

7:14 PM

Page 947

Champ® Pro PFM Series
Luminaires

2L

UL/cUL Listed
NEMA 4X
IP66

Perfect for outdoor/indoor flood illumination
Drivers:

The Champ® Pro PFM
Family

Model

Champ® Pro PFM Series Floodlights are
designed to provide full-spectrum, crisp,
white light. Five versions of the Champ
PFM LED are available, providing ideal
solutions for a wide range of applications.

90-305 VAC, 50 / 60
Hz; 108-250 VDC
347 VAC Model
480 VAC Model

Standard
Option 1
Option 2

Standard Materials:

Champ® Pro
PFM Model

Equivalent
MH HID
Lamp

PFM5L
PFM7L
PFM9L
PFM11L
PFM13L

100W-150W
150W-175W
175W-250W
250W-400W
400W

Energy
Savings

• Housing – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens – shatter-resistant glass

Up to
62%!

• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals
required

Certifications and
Compliances:
•
•
•
•
•

5L - 13L

LED System:

UL1598
UL1598A
cUL
NEMA 4X; IP66
DesignLights Consortium® approved for
select models (refer to Ordering
Information for details)

• High brightness light emitting diode
(LED) arrays
• Color temperature: 3000K (CRI 82) and
5600K (CRI 65) options available
• Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions

Electrical Ratings:
PFM5L

PFM7L

PFM9L

PFM11L

PFM13L

100-277V 50-60 Hz

Voltage Range, VAC

347 / 480V 60 Hz
108-250

108-250

108-250

108-250

108-250

Input Power (Nom.)

64

89

121

149

179

Input Amps (Max.)

0.550

0.800

1.083

1.608

1.608

Power Factor

>0.85

>0.85

>0.85

>0.85

>0.85

2L

Voltage Range, VDC

Ordering Information:
Color Temperature
Cool Color Temperature

5L Series

7L Series

9L Series

11L Series

13L Series

PFM5LCY/UNV1 76 PFM7LCY/UNV1 76 PFM9LCY/UNV1 76 PFM11LCY/UNV1 76 PFM13LCY/UNV1 76
PFM5LCY/120 76*

PFM7LCY/120 76*

PFM9LCY/120 76*

PFM11LCY/120 76*

PFM13LCY/120 76*

Warm Color Temperature PFM5LWY/UNV1 76 PFM7LWY/UNV1 76 PFM9LWY/UNV1 76 PFM11LWY/UNV1 76 PFM13LWY/UNV1 76
For 347 VAC option, replace /UNV1 with /347. For 480 VAC option, replace /UNV1 with /480.
To order fixture without optics, remove ‘76’ from the end of the catalog number.
*5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions. DesignLights Consortium approved
models. Cool white only.

Options:
Description
Suffix
Fused (only applies to UNV1 model, not available for 347V or 480V; NOT marine or cUL Listed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658
Two conduit/cable glands of like thread installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S886

Accessories:
Description

Catalog No. Sold Separately

Bolt-on visor (sold separately)
Bolt-on wire guard (sold separately)
Floodlight slipfitter (sold separately)
Slipfitter wall mount adapter (sold separately)

DSV1
P61
SFA6
SWB6

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

947

948-949.qxp

12/16/2013

7:15 PM

Page 948

Champ® Pro PFM Series
Luminaires

2L

UL/cUL Listed
NEMA 4X
IP66

Perfect for outdoor/indoor flood illumination
Dimensions:
[167.1]
6.6

[532.9]
21.0

[552.5]
21.75
[405.9]
16.0

[14]
Ø.55

[120.7]
4.75

Photometric Data:

Weights:
Model

Lbs.

5L
7L
9L
11L
13L

39.11
39.16
39.73
40.35
40.35

PFM13L @ 30 Ft. High; Tilt Angle = 45 Degrees
(Isofootcandles)

2L

Ambient Temperature:
Champ® Pro PFM Model

Max. Temp. ºC

PFM5L

55

PFM7L

55

PFM9L

55
40

PFM11L

55
40

PFM13L

55
Point By Point FC Readings

Distance in Feet

.35 Fc

.5 Fc

1 Fc

2 Fc

2.5 Fc

MULTIPLIERS FOR OTHER LED FLOODLIGHTS
Luminaire
Series

Wattage
64

4386

PFM7L

89

6720

PFM9L

121

8478

PFM11L

149

10420

*PFM 13L output is 12,940.

948

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Lumens*

PFM5L

Copyright© 2013 Eaton’s Crouse-Hinds Business

948-949.qxp

12/16/2013

7:15 PM

Page 949

Champ® Pro PFM Series 25L
and 50L LED Floodlights

2L

UL/cUL Listed
NEMA 4X
IP66

The Champ® Pro PFM LED
Family
PFM LED Series Floodlights are designed
to provide full-spectrum, crisp, white light.
Two versions of the Champ Pro PFM LED
are available, providing ideal solutions for
a wide range of applications.

PFM
Model

Equivalent
HID Lamp

Energy
Savings

PFM25L 750W MH
1500W MH /
PFM50L
1000W HPS

PFM25L Model
Up to 65%!

PFM50L Model

Applications:

Certifications and
Compliances:

Standard Materials:
• Housing – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens – heat- and impact-resistant glass
• Yoke mount (standard) – copper-free
aluminum with Corro-free™ epoxy
powder coat
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals
required

LED System:
• High brightness light emitting diodes
(LEDs)
• Color temperature: 5000K (CRI 67)
• Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions
• LM-79, LM-80 reports available upon
request

Description
Two conduit/cable glands of
like thread installed ...................
Diffused glass lens ....................
Polycarbonate lens....................

Suffix
S886
S891
S903

Accessories:
Description

Cat. # (Sold
Separately)

Bolt-on visor
(sold separately)....................
Bolt-on wire guard
(sold separately)....................
Floodlight slipfitter
(sold separately)....................
Slipfitter wall mount adapter
(sold separately)....................

DSV1
P61
SFA6*
SWB6*

*Available with PFM25L model only.

Drivers:
PFM Model
/UNV1
/UNV34

25L, 50L
90-305 VAC, 50 / 60 Hz;
127-250 VDC
277-480 VAC Model

Electrical Ratings:

•
•
•
•
•

UL1598
UL1598A
cUL
NEMA 4X; IP66
DesignLights Consortium® approved for
select models (refer to Ordering
Information for details)
• UL approved up to 40°C ambient

PFM25L

PFM50L
120-277V 50 / 60 Hz

Voltage Range, VAC

277-480V 50 / 60 Hz

Voltage Range, VDC

127-250V

Input Power (Nom.)

263

531

Input Amps (Max.)

2.6

5.2

Power Factor

>0.90

Ordering Information:
25L Series†*

50L Series

PFM25LCY/UNV1 76
PFM50LCY/UNV1 76
NOTE: Available in cool color temperature only. For 277-480 VAC option, replace /UNV1 with /UNV34.
†DesignLights Consortium® approved model at 120-277V.
*PFM25L is DLC approved with a 5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard terms and conditions.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

949

2L

• High lumen output for installation in high
mounting heights
• Locations requiring continuous and
consistent light levels
• Areas requiring frequent on-and-off of
lights
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist; indoors
or outdoors
• NEMA 4X, marine, wet locations, and
hose-down environments
• Indoor and outdoor area lighting in
plants, buildings, and parking areas
• Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; platforms;
loading docks; outdoor mounted general
area lighting
• Ball mills, stackers and reclaimers,
concentrators, smelters, mine roadways,
outdoor processing areas, truck service
shops, shovels, and drag lines

Options:

950-951.qxp

12/16/2013

2L

7:41 PM

Page 950

Champ® Pro PFM Series 25L
and 50L LED Floodlights

UL/cUL Listed
NEMA 4X
IP66

High efficiency and lumen output

The heat sink was designed to perform in
high ambient temperatures up to +40ºC and
as low as -25ºC. The thick walls of the
castings make for a tough, rugged housing
that keeps the internal driver and LED
temperatures down, allowing them to
perform flawlessly, and protects them from damage. Separated driver
and LED housing allows dust to shed from fixture.

High efficiency drivers and LEDs provide 100 LPW for
reliable low cost operation in industrial environments.
Components were chosen to give industry-leading
light output from an LED flood. Replaceable drivers
and LEDs for ease of maintenance and “no lights out”
feature.

2L

Safe, reliable heat transfer

Versatile design
Can be used for outdoor or indoor
applications, and for a wide range of
mounting heights depending on model and
light level requirement. Optics were
specifically designed to give the familiar
and industry-accepted NEMA 7x6 beam
light pattern.

950

www.crouse-hinds.com

US: 1-866-764-5454

Optional equipment (sold separately)
Optional visor offered to control light spill.
Optional wire guard offered to protect lens from damage.
Other options available - consult part numbering guide.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

950-951.qxp

12/16/2013

7:41 PM

Page 951

Champ® Pro PFM Series 25L
and 50L LED Floodlights

UL/cUL Listed
NEMA 4X
IP66

2L

Dimensions:
532.9
21.0

277
10.9

552.5
21.75

234.5
9.2
203.7
8.0

405.9
16.0

525.6
20.7

120.7
4.75

.55

PFM25L Model
277
10.90

556.3
21.90

254
10.00

235.8
9.28

532.9
20.98

203.7
8.02

13.9
Ø .55

127
5.00

825
32.48

632.6
24.90

PFM50L Model

Photometric Data:
200

175

150

125

100

75

50

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.4

0.4

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.4

0.4

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.4

0.5

0.5

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.5

0.5

0.4

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.5

0.6

0.6

0.7

0.7

0.7

0.8

0.7

0.7

0.7

0.6

0.6

0.5

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.4

0.5

0.6

0.7

0.8

0.9

0.9

0.9

0.9

0.9

0.8

0.7

0.6

0.5

0.4

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.4

0.5

0.5

0.6

0.6

0.6

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.5

0.6

0.8

0.9

1.0

1.1

1.2

1.2

1.2

1.1

1.0

0.9

0.8

0.6

0.5

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.5

0.6

0.7

0.7

0.8

0.7

0.7

0.6

0.5

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.6

0.7

0.9

1.1

1.3

1.5

1.6

1.6

1.6

1.5

1.3

1.1

0.9

0.7

0.6

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.5

0.7

0.8

0.9

1.0

1.0

1.0

0.9

0.8

0.7

0.5

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.5

0.6

0.8

1.1

1.4

1.7

1.9

2.1

2.1

2.1

1.9

1.7

1.4

1.1

0.8

0.6

0.5

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.5

0.6

0.8

1.1

1.2

0.1

0.2

0.3

0.4

0.5

0.7

0.9

1.3

2.8

2.9

2.8

2.2

1.7

1.3

0.9

0.7

0.5

0.4

0.3

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.4

0.5

0.7

1.0

1.3

1.6

0.1

0.2

0.3

0.4

0.5

0.7

1.0

1.5

2.0

2.7

3.3

3.7

3.9

3.7

3.3

2.7

2.0

1.5

1.0

0.7

0.5

0.4

0.3

0.2

0.1

0.1

0.2

0.2

0.4

0.5

0.8

1.1

1.7

2.4

3.4

4.3

5.0

5.1

5.0

4.3

3.4

2.4

1.7

1.1

0.8

0.5

0.4

0.2

0.2

0.1

0.2

0.2

0.4

0.6

0.9

1.3

2.1

3.2

4.6

6.3

7.4

7.9

7.4

6.3

4.6

3.2

2.1

1.3

0.9

0.6

0.4

0.2

0.2

0.1

0.1

0.2

0.3

0.4

0.7

1.1

1.5

1.9

3.0

6.5

8.0

8.5

8.0

6.5

4.5

3.0

1.9

1.1

0.7

0.4

0.3

0.2

0.1

0.1

1.3

1.4

1.3

1.2

1.1

0.8

0.6

0.5

0.3

0.2

0.2

0.1

0.1

0.1

1.8

1.9

1.8

1.6

1.3

1.0

0.7

0.5

0.4

0.2

0.2

0.1

0.1

0.1

175

150

125

100

75

50

2

25

0

0.1

0.1

0.1

0.2

0.3

0.4

0.1

0.1

0.1

0.2

0.3

0.0

0.1

0.1

0.1

0.2

.1

.5

1.7

2.1

2.4

2.5

2.4

2.1

1.7

1.2

0.8

0.6

0.4

0.3

0.2

0.1

0.1

0.1

1.6

2.3

3.1

3.7

3.9

3.7

3.1

2.3

1.6

1.0

0.7

0.4

0.3

0.2

0.1

0.1

0.1

1.5

2.2

3.1

3.8

3.8

3.1

2.2

1.5

0.9

0.6

0.3

0.2

0.1

0.1

0.1

0.0

0.6

0.8

1.2

0.4

0.7

1.0

0.3

0.6

0.9

.25

1

1.5

3

4

4.1

25

0.1

0

0.25

0.15

0.5

1

Point By Point Foot-Candle Readings

-125

-100

-75

-50

-25

0

25

1.7

2.2

2

4

4.5

0.25

0.50

1.00

1.50

3

5

2.6

PFM Model

Lbs.

PFM25L
PFM50L

52.00
106.00

0.2

0.1

Point By Point Foot-Candle Readings

50

75

100

125

-125

-100

-75

-50

Distance In Feet

0.10

2.6

2L

Weights:

PFM50L @ 50 Ft. High

PFM25L @ 50 Ft. High
200

-25

0

25

75

50

100

125

Distance In Feet

2.00

3.00

4.00

0.15

0.25

0.50

1.00

1.50

2.00

3.00

4.00

5.00

Footcandles

Footcandles

Luminaire
Series

Wattage

Lumens

Luminaire
Series

Wattage

Lumens

PFM25L

263

26,240

PFM50L

531

53,890

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

951

952-953.qxp

12/16/2013

7:16 PM

Page 952

Vaporgard™ Pro P2L
Series Luminaires

2L

UL/cUL Listed
NEMA 4X
IP66

For targeted illumination in low
mounting height areas
Standard Materials:

The Vaporgard™
Pro P2L Family
P2LC/UNV1 - Cool White Color
Temperature
The P2LC/UNV1 Luminaire
provides uniform crisp, white
light and is suitable for lower
mounting heights, confined spaces,
tunnels, or utility rooms. Using four
high power, high brightness LED
arrays, this fixture can deliver similar
light levels to 150 watt incandescent.
P2LW/UNV1 - Warm White Color Temperature
The P2LW/UNV1 Luminaire provides similar benefits as the cool white
version, but with a color rendering more consistent with a warm
incandescent or HPS lamp source. Perfect for situations where
Vaporgard Pro will be installed next to a warmer color light source.
DC Power Supply - Available for Applications Requiring
DC Power
For applications with DC power requirements such as solar or back-up
battery. The DC power supply is suitable for 12VDC through 24VDC.

Certifications and Compliances:
•
•
•
•
•

UL1598
UL1598A
cUL
NEMA 4X; IP66
DesignLights Consortium® approved for select models (refer to
Ordering Information for details)

2L

Electrical Ratings:
Voltage
Input Power (Watts)
Input Current
Power Factor
THD (I) (%)
Maintained Lumens
Efficacy, LPW
Color Temperature

• Body and mounting modules – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens bezel – aluminum with anodized finish
• Lens – heat- and impact-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals required

LED Array:
•
•
•
•

(4) High brightness LED arrays
Cool white (5600K), CRI 65
Warm white (3000K), CRI 82
70% lumen maintenance (L70) at 50K hours

LED Driver:
•
•
•
•
•
•
•
•

Constant current regulated power supply
90VAC - 264VAC, 277VAC, 50 / 60 Hz
Internal fusing
Active power factor correction, >0.9
Low harmonic distortion, <20%
Low inrush current, <20 amps
EMC compliant to 47CFR, Part 2, Part 15
12VDC / 24VDC option available

Series
P2LC/UNV1*

P2LW/UNV1

P2LC/DC1

P2LW/DC1

90-264VAC, 277VAC
22
0.23 / 0.10
>0.9
<20%
1633
64
5600K

90-264VAC, 277VAC
22
0.23 / 0.10
>0.9
<20%
1400
56
3000K

12-24VDC
22
2.1 / 1.0
N/A
N/A
1633
64
5600K

12-24VDC
22
2.1 / 1.0
N/A
N/A
1400
56
3000K

*5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions.
DesignLights Consortium approved models.

Ordering Information:
Cool White

Warm White

Mounting Style

AC Drive**

DC Drive

AC Drive

DC Drive

/2" Pendant

P2LCA1/UNV1**

P2LCA1/DC1

P2LWA1/UNV1

P2LWA1/DC1

1
3

/4" Pendant

P2LCA2/UNV1**

P2LCA2/DC1

P2LWA2/UNV1

P2LWA2/DC1

1" Pendant

P2LCA3/UNV1**

P2LCA3/DC1

P2LWA3/UNV1

P2LWA3/DC1

/2" Wall with Junction Box

P2LCHBF1/UNV1**

P2LCHBF1/DC1

P2LWHBF1/UNV1

P2LWHBF1/DC1

/4" Wall with Junction Box

P2LCHBF2/UNV1**

P2LCHBF2/DC1

P2LWHBF2/UNV1

P2LWHBF2/DC1

/2" Ceiling

P2LCHF1/UNV1**

P2LCHF1/DC1

P2LWHF1/UNV1

P2LWHF1/DC1

/4" Ceiling

P2LCHF2/UNV1**

P2LCHF2/DC1

P2LWHF2/UNV1

P2LWHF2/DC1

/2" VXT Wall

P2LCHT1/UNV1**

P2LCHT1/DC1

P2LWHT1/UNV1

P2LWHT1/DC1

/4" VXT Wall

P2LCHT2/UNV1**

P2LCHT2/DC1

P2LWHT2/UNV1

P2LWHT2/DC1
P2LWHW1/DC1

1
3
1
3
1
3

/2" VXW Wall

P2LCHW1/UNV1**

P2LCHW1/DC1

P2LWHW1/UNV1

3

/4" VXW Wall

P2LCHW2/UNV1**

P2LCHW2/DC1

P2LWHW2/UNV1

P2LWHW2/DC1

11/4" Stanchion

P2LCHJ4/UNV1**

P2LCHJ4/DC1

P2LWHJ4/UNV1

P2LWHJ4/DC1

Adapter Only*

P2LCHR/UNV1**

P2LCHR/DC1

P2LWHR/UNV1

P2LWHR/DC1

1

*For use when wall mount or ceiling mount box is already installed.
**5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions.
DesignLights Consortium approved models. Cool white only.

952

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

952-953.qxp

12/16/2013

7:16 PM

Page 953

Vaporgard™ Pro P2L
Series Luminaires

2L

UL/cUL Listed
NEMA 4X
IP66

For targeted illumination in low
mounting height areas
Options:

Accessories (Order Separately):

Description
Frosted lens reduces glare in applications where the user may
have direct visual contact with the light source . . . . . . . . . . . .
Teflon coating on lens provides additional shatter protection
for applications in food and beverage facilities . . . . . . . . . . . . .
High temperature option allows operation up to 55°C ambient
temperature (AC unit only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Suffix
S891
S896
S902

Description
Cat. No. Sold Separately
Magnet bracket only
(available for ceiling mount
VXF20 only) . . . . . . . . . . . . . . . . . . P2L Magbrk
Magnet bracket kit
(includes ceiling mount) . . . . . . . . . P2L Magbrk K1

Dimensions:
Pendant

Wall
11 1/4
[285.1]

8 3/4
[221.7]

Ceiling

Stanchion

8 3/4
[221.7]

6 7/8
[175]

11 13/16
[299.9]

15/16
[23.9]

3/4" NPT HUB
1/2" REDUCER
SUPPLIED

Ø4 9/16
[Ø116.0]

Ø1/4
[Ø7.1]

4 3/4
[121.3]

3 7/8
[99]

8 1/8
[206.7]
1-1/4" HUB

45°

5

1/2” NPT OR 3/4" NPT HUB

8 3/4
[221.7]

4 1/2
[114.7]
4 11/16
[119.8]
3 7/8
[99.2]

VLA1 1/2" NPT HUB
VLA2 3/4" NPT HUB
VLA3 1" NPT HUB

5 7/8
[149.1]
1 3/4
[44]

3 7/8
[98.5]

2 1/8
[53.4]

5 3/4
[146.2]

1
[25.4]

1/4
[5.6]
1
[25.4]

2 1/8
[53.9]

Ø4 15/16
[125.2]

1 3/4
[44]

1 3/4
[44]

7 1/16
1 [179.7]
[25.4]

1
[25.4]

8 3/4
[221.7]

1 3/4
[44]

Family Tree:
2L

VXF 10 VXFT 10
VXF 20 VXFT20
VXJ4

VXW2
VLA1
VLA2
VLA3

VXT20
VXF 10 VXFT 10
VXF 20 VXFT20

VLHR

P2L LED
Housing

VAPORGARD P2L SERIES
Complete luminaire consists of LED
Housing and Cover: a VLA pendant, or
a VLHR adapter and VX series
mounting module shown.

Weights:

Ambient Temperature:

Luminaire & Mounting Module Weight
Pendant Mount
Ceiling Mount
Wall Mount
Stanchion Mount

Lbs.
5.7
6.8
7.9
6.5

www.crouse-hinds.com

Vaporgard™ Pro P2L Model
P2L/UNV1

US: 1-866-764-5454

Max. Temp. °C
40

P2L/UNV1 S902

55

P2L/DC1

40

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

953

954-955.qxp

12/16/2013

7:16 PM

Page 954

Vaporgard™ Pro P2L
Series Luminaires

2L

UL/cUL Listed
NEMA 4X
IP66

For targeted illumination in low
mounting height areas
Photometric Data:
Vaporgard™ Pro LED (22 Watt)

DISTANCE TO MOUNTING HEIGHT
Isofootcandle chart shows illuminance in
foot-candles at ground level
3

CANDLEPOWER DISTRIBUTION (IN CANDELAS)

2
1
0
-1
-2
1000

-3

1500

-3

-2

-1

0

1

2

3

2000

ISOFOOTCANDLE CHART

2500

Footcandle Values for Isofootcandle Lines
3000
3500
A

4000

B

C

D

E

F

4500
5000

2L

5500

ZONAL LUMENS

954

ZONE

LUMENS

% LUMEN

0-30

468

28.65

0-40

772

47.30

0-60

1374

84.15

0-90

1633

100.00

40-90

860

52.70

60-90

259

15.85

90-180

0

0.00

0-180

1633

100.00

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Mtg.
Hgt.

A

B

C

D

E

F

6’

10.00

5.00

2.00

1.00

0.50

0.20

8’

5.62

2.81

1.13

0.56

0.28

0.11

10’

3.60

1.80

0.72

0.36

0.18

0.07

12’

2.50

1.25

0.50

0.25

0.13

0.05

14’

1.84

0.92

0.37

0.18

0.09

0.04

Copyright© 2013 Eaton’s Crouse-Hinds Business

954-955.qxp

12/16/2013

7:16 PM

Page 955

Meets UL1598/cUL
construction requirements*

Industrial High Bay LED
Series Luminaires

Applications:

Electrical Ratings:

• Locations requiring continuous and
consistent light levels
• Areas requiring frequent on-and-off of
lights
• Areas that are difficult to relamp or that
cause production to be stopped during
the lamp maintenance process
• Ordinary clean, light industrial
production facilities, packaging facilities,
and warehouses
• Indoor and dry locations only

• 100 VAC to 277 VAC 50 / 60 Hz
• 347 VAC to 480 VAC 50 / 60 Hz

Features:
• Up to 69% energy savings over 400W
metal halide fixtures
• 60,000 hours (rated life) of maintenancefree operation for labor and material
savings over the life of the fixture
• Two to three year payback by retrofitting
four or six lamp T5HO or 400W metal
halide high bay fixtures
• Operating temperature of -30°C to
+40°C ambient
• Uniform wide distribution for optimum
lighting levels for 18-25 foot mounting
heights
• Occupancy sensing control available for
enhanced energy savings and lifetime of
LED fixture
• Hook and cord attachment for 3/ 4"
pendant hub
• 347-480 VAC driver option

Certifications and
Compliances:

*Not UL Listed.
**For /UNV1 model. Refer to page 2 of the D-0413
authorized distributor price book for Eaton's CrouseHinds standard Terms and Conditions.

P.F.

THD

Amps

120
277

0.995
0.950

8.16%
12.3%

1.178
0.524

Ordering Information:
Cat. #
IHB13L2A/UNV1

Note:

Description
Industrial High Bay,
13,940 Lumens, 3/ 4"
Pendant Mount,
100-277 VAC

Accessories:

For 347-480 VAC, replace /UNV1 with /UNV34.

Description

Cat. # (Sold
Separately)

Occupancy sensor kit,
3
/ 4" entry (sold separately) .........IOS2/UNV1‡
Hook and cord kit
(sold separately) ........................IHB HC KIT
Driver replacement kit
IHB PS/
(sold separately) ........................ UNV1 KIT

Options:
Description
Suffix
Hook and cord attachment
for 3/ 4" pendant hub ...................... HC

‡For 347-480 VAC, replace /UNV1 with /UNV34.

Specifications:
Key Specifications
Lumens (Typical)†

13,940

Wattage

141W (at 120 VAC); 138W (at 277 VAC)

Lumens Per Watt (LPW)

99

Color Temperature

5,000K

CRI

>70

Voltage Range (VAC)

100-277V, 347-480V; 50 / 60 Hz

Power Factor

0.95 at 277 VAC

Total Harmonic Distortion

12.3% at 277 VAC

Operating Temperature

-30°C to +40°C

Lifetime

60,000 hours at +40°C

Warranty

5 years**

2L

• Meets UL1598 and cUL construction
requirements*
• DesignLights Consortium®**

Voltage

2L

†Tolerance +/- 10%.
**For /UNV1 model. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms
and Conditions.

Dimensions:
445
17.5
237
9.3
363
14.3

153
6.0
134
5.3 82
3.2

70
2.8

www.crouse-hinds.com

3/4"-14 CONDUIT CONNECTION

208
8.2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

955

956-957.qxp

12/16/2013

7:16 PM

Page 956

Endure™ LED Wall Pack

2L

UL/cUL Listed
IP66

For mining and heavy industrial applications
Endure™ LED Wall Pack
Family

Standard Materials:

Model

Equivalent HID
Output

Energy
Savings

• Housing – 16 gauge stainless steel
(SS201), painted powder coat white;
optional 316 stainless steel housing
available for extreme corrosion resistance
• Door – die-formed stainless steel with
0.156" thick clear tempered glass lens;
316 stainless steel (optional)
• Gasket – silicone, around perimeter of
glass
• Screws – stainless steel

FM1 B01
FM1 B02

50W HPS
70W HPS/MH

59%
43%

Standard Finish:

The IP66, stainless steel Endure™ LED
Luminaire features the patented, modular
LED LightBAR™ technology. The Endure
LED Luminaire is available with one or two
LightBAR configurations in Type II or Type
V distributions.

Applications:
• Ideal for a variety of non-hazardous
applications such as mining, food
processing, marine, wastewater
treatment, heavy manufacturing, and
general wash-down areas

E
D
B

C

A

• All external components are finished in a
polyester white powder coat paint,
electrostatically applied

Design Features:
A White light - provides superior color rendering and ambient clarity. Optics are precisely

designed to shape the distribution, maximizing efficiency and application spacing.
B Energy efficiency and longer life – 50,000 hours rated life and up to 59% more energy-

Certifications and
Compliances:

efficient than the 70W high pressure sodium equivalent.
C Reduction in light pollution – controlled distribution of light means far less light loss.
D IP66 ingress protection rating and -30°C to 50°C ambient temperature rating – ensures

• UL1598
• cUL
• IP66

trouble-free operation in a variety of harsh and complex applications.
E Junction box – polycarbonate, IP66 rated, four screws to access cover, double row terminal

box to expedite installation.

2L

LED System:
• Choice of Type II or Type V high
efficiency AccuLED™ optics designed
to shape light distribution for
maximizing efficiency and application
spacing
• 50,000+ hour life with >70% lumen
maintenance
• 4000K (± 275) CCT and nominal 70 CRI
• 98 lumens per watt; 0.9 power factor

Electrical Ratings:
Distribution
No. of
LightBARs

Power
(Watts)

Current @
120V(A)*

1

27

0.23

2

51

0.43

Current @
277V(A)*

Lumens
(Type II)

Lumens
(Type V)

0.13

2304

2382

0.20

4571

4726

21 LED LightBAR

*Proprietary circuit module designed to withstand 10kV of transient voltage surge.

Ordering Information:
PRODUCT
FAMILY

NO. OF
LIGHTBARS

LAMP
TYPE

FM1

B01

LED

ELECTRICAL DISTRIBUTION
E1

T2

Product Family

Finish

FM1

WH
BK
BZ

Endure Luminaire

No. of LightBARs
B01
B02

(1) 21 LED LightBAR
(2) 21 LED LightBARs

FM1-EBP-WH

Solid State Light Emitting Diodes

Electrical
E1

FINISH

ACCESSORIES

OPTIONS

CTG156

WH

FM1-EBP-WH

316SS

White Powder Coated Paint
Black Powder Coated Paint
Bronze Powder Coated Paint

Accessories

Lamp Type
LED

LENS

Electronic Driver (1) (120-277V)

Distribution

Options

T2
5MQ

316SS

Type II
Type V

EM Battery Pack Unit (Coming Soon)
Same dimensions as non-EM unit
but with full stainless steel door.
Replace ‘WH’ in the catalog number with
‘BK’ or ‘BZ’ for black or bronze finish.
Includes test switch and indicator light.
Type 316 Stainless Steel Housing and Door

Lens
CTG156 Clear Tempered Glass, 0.156” Thick
PC125 Clear Polycarbonate, 0.125” Thick
AC125 Clear Acrylic, 0.125” Thick
956

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

956-957.qxp

12/16/2013

7:16 PM

Page 957

Endure™ LED Wall Pack

2L

UL/cUL Listed
IP66

For mining and heavy industrial applications
Dimensions:
Top View (2 LightBAR Configuration Shown)

End View
8.5” [215.1mm]

8.5”
[215.1mm]

3.7”
[94mm2]

10”
[254mm]

5.75”
[145.9mm]

13.7” [348mm]
17.1” [434mm]

10” [254mm]

Side View

Mounting

17.1” [434mm]
13.7” [348mm]

8”
[200mm]

5.7”
[146mm]
7” [178mm]

Photometric Data:

Type II Distribution
3877

3182

2908

2386

1939

1591

969

795

H

V

2L

V

Type V Distribution

H

Lumen Multiplier (2 Bar)
Temperature

Multiplier

Lumens

10°C
15°C
25°C
40°C
50°C

1.09
1.03
1.00
0.96
0.92

5151
4868
4726
4537
4348

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

957

958-959.qxp

12/16/2013

7:16 PM

Page 958

2L

2L

958

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

958-959.qxp

12/16/2013

7:16 PM

Page 959

3L

High Intensity Discharge
(H.I.D.) Lighting
Hazardous and Non-hazardous
Description

Page No.

Application/Selection

see page 960

Champ Series – Integrally Ballasted Luminaires
®

Accessories
Ballast Data (USA)
Ballast Data (Canada)

see pages 1022–1023
see page 874
see page 874

VMV Series 50 – 175W H.I.D
Catalog Listings
Temperature Data, Dimensions, Weights
Photometric Data

LMV Series 50 – 150W H.I.D
Catalog Listings
Temperature Data, Dimensions, Weights
Photometric Data

DMV Series 50 – 250W H.I.D.
Catalog Listings
Temperature Data, Dimensions, Weights
Photometric Data

VMV High Wattage Series 200 – 400W H.I.D.
Catalog Listings
Temperature Data, Dimensions, Weights
Photometric Data

see page 962
see page 963
see page 968
see pages 970–971
see
see
see
see

page
page
page
page

972
973
977
979

see
see
see
see

page
page
page
page

980
981
986
988

see
see
see
see

page
page
page
page

989
990
995
997

VMVIG Series Induction Lighting

see pages 998–1004

DMVIG Series Induction Lighting

see pages 998–1004

N2MV Non-metallic H.I.D.

nVMV Ex-Protected Luminaire for IEC and ATEX
Applications
Catalog Listings
Temperature Data, Dimensions, Weights
Photometric Data

Photocells

www.crouse-hinds.com

US: 1-866-764-5454

see
see
see
see

page
page
page
page

1005
1006
1011
1013

see page 1014
see page 1015
see page 1016
see pages 1018–1021
see page 1024

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

959

3L

Catalog Listings
Temperature Data, Dimensions, Weights
Photometric Data

960-961.qxp

12/16/2013

7:17 PM

Page 960

H.I.D. (High Intensity Discharge)
Luminaires

3L

Enclosed & Gasketed
Application and Selection
Applications:
Luminaires included in this section are
enclosed and gasketed, designed for use
with H.I.D. lamps as follows:
• In locations where protection is required
from wet, dirty and corrosive
atmospheres
• Where long life lamps provide desirable
maintenance cost savings and return on
investment through use of fewer
luminaires, circuits and ancillary
apparatus
• Where relamping and maintenance
difficulties require long life lamps

Considerations for
Selection:
Environmental:
• What are the hazardous areas
classifications (NEC/CEC) of the
locations in which the luminaires will be
installed?
• Must luminaires be suitable for use in
marine, hosedown, corrosive
applications?
Lighting levels required:
• What wattage luminaire(s) will provide
the desired light level?

Quick Selector Chart*
Series

Watts
HPS, MH &
Pulse Start MH Lamps

Champ VMV

50, 70, 100, 150, 175
Mogul Base

Hazardous Area & Other
Enviromental Suitabilities
NEC, CEC, IEC

NEC & CEC

Champ VMV
High Wattage

Cl. I, Div. 2 Groups A, B, C, D
Cl. II, Groups E, F, G
Cl. III
Simultaneous Presence

200, 250, 400
Mogul Base

Ballast Voltages

Standard Voltage Ballasts
(60 Hz)
NEC (UL)
Multi-tap: 120, 208, 240 & 277 Volt 60 Hz.
Dual-tap: 120 & 277 Volt 60 Hz (50W HPS)
120 Volt 60 Hz
480 Volt 60 Hz

3L

CEC/CSA (cUL)
Tri-tap: 120, 277 & 347 Volt 60 Hz
Restricted Breathing (Suffix – S826)
Cl. I, Div. 2 & Zone 2 AEx nR, Ex nR IIC Dual-tap: 120 & 277 Volt 60 Hz (50W HPS)
120 Volt 60 Hz
Marine Outdoor & Wet Locations
Champ LMV
Low Profile

50, 70, 100, 150
Medium Base

Champ DMV
Expanded
Class II Suitability

50, 70, 100, 150, 175, 250
Mogul Base

Champ N2MV
Non-metallic

50, 70, 100, 150, 175
Mogul Base

Optional Voltage Ballasts
(50 or 60 Hz)

Type 3, 3R, 4, 4X
IP56 to IP66
IEC
Certified for IEC Zone 2
(Suffix – S826TB)
Ex nR IIC

208
240
480
600

IP56 to IP66

Zone 2 according to IEC
Ex nR II T...Gc
Champ nVMV
Ex-Protected Luminaire
for IEC and ATEX
Applications

70 Medium
100, 150 Medium & Mogul
250, 400 Mogul

Zone 21 and 22 according to IEC
Ex t IIIC T...ºC Db IP66
IP66
ATEX

*See specific sections for lamp type and wattage suitability.

960

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

CEC/CSA (cUL)
Volt 60 Hz CWI – Isolated
Volt 60 Hz CWI – Isolated
Volt 60 Hz CWI – Isolated
Volt 60 Hz CWI – Isolated
EXPORT
220 Volt 50 Hz
230 Volt 50 Hz
240 Volt 50 Hz
220 Volt 50 Hz
230 Volt 50 Hz
240 Volt 50 Hz
220 Volt 60 Hz
230 Volt 60 Hz
240 Volt 60 Hz

960-961.qxp

12/16/2013

7:17 PM

Page 961

Champ® H.I.D. Luminaires
VMV, LMV, DMV, VMV
High Wattage, N2MV & nVMV Series

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups E, F, G, Cl. III
Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

3L

The Champ family is an extremely versatile
industrial lighting system. Six different
series of Champ Luminaires embrace a
broad range of wattages, lamp sources,
compliances, optics, and accessories.
Each series is covered in detail on the
following pages. General information to
help in the proper selection of series and
luminaires is shown below.

Applications:
Heavy duty Champ lighting luminaires are
used:
• In manufacturing plants, refineries,
chemical, petrochemical, and other
industrial process facilities, waste or
sewage treatment facilities, offshore,
dockside, and harbor installations, and
other heavy industrial applications
• In areas where ignitible concentrations of
flammable gases or vapors will be
present only due to abnormal, unusual,
or accidental conditions
• Where combustible dusts are present
• In marine applications where water spray
and corrosive atmospheres are
considerations
• In elevated ambient temperatures often
found in industrial applications
• In installations where moisture, dirt, dust,
vibration, corrosion, and rough usage are
problems
• Wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements are found

Features:
3L

• Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent
resistance to corrosion.
• Seven mounting arrangements in each
series, to suit any lighting layout –
pendant, flexible pendant, ceiling, wall
bracket, angle stanchion, straight
stanchion, and quadmount.
• Wide range of light sources and
wattages to meet specifiers' needs: 50,
70, 100, 150, 200, 250 and 400 watt high
pressure sodium (HPS); 70, 100 175,
250, and 400 watt metal halide (MH and
Pulse Start MH).
• Hinged ballast housings for ease of
installation and maintenance; all
mounting modules fit all ballast housings.
• Wide choice of photometric distributions.
Globes available for lamps up through
400 watt HPS, and 250 watt MH. Glass
refractors available for all VMV and DMV
units; reflector/lens for 200–400 watt
VMV units.
• All luminaires are designed to perform in
a 40°C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C.

• Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in
wet and corrosive environments.
• Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
• Low ambient capability to –40°C.
• Dome and 30° angle reflectors made of
bright white Krydon® fiberglassreinforced polyester material provide
superior reflectivity, with twist-on feature
requiring no tools or additional
hardware. Will not chip, peel, dent, rust,
or corrode.
• Grounding wire for safety.
• Ballasts are high power factor
(min P.F. 90%) and available in a
variety of voltages to meet local area
requirements.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

961

962-963.qxp

12/16/2013

3L

7:17 PM

Page 962

VMV Series 50–175W
Champ® H.I.D. Luminaires

Applications:

Options:

VMV series Champ luminaires are used:
• In manufacturing plants, refineries,
chemical, petrochemical, and other
industrial process facilities, waste or
sewage treatment facilities, offshore,
dockside, and harbor installations, and
other heavy industrial applications
• In areas in which ignitible concentrations
of flammable gases or vapors will be
present only due to abnormal, unusual,
or accidental conditions
• Where combustible dusts are present
• In marine applications where water
spray and corrosive atmospheres are
considerations
• In elevated ambient temperatures often
found in industrial applications
• In installations where moisture, dirt,
dust, vibration, corrosion, and rough
usage are problems
• Wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements are found

The following special options are available
from the factory by adding suffix to luminaire
Cat. No.:
Description
Suffix
Factory Sealed Champs . . . . . . . . . . .S865
Class I, Division 2 & Zone 2
Provides T3 code without
conduit or cable seals
Restricted breathing/Non-sparking
Restricted Breathing Construction . . .S826
Class I, Division 2 & Zone 2
Suitabilty
Cooler Operating Temperatures
(T-Numbers)
Certified for IEC Zone 2 . . . . . . . . . . .S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT or TT)
Fused – to protect ballast and
capacitors against abnormal line
conditions . . . . . . . . . . . . . . . . . . . . . .S658*
(Not available with /MT Ballast)
(Not for use in Canada)
(Not suitable for marine applications)
Quick-Clip - Holds weight of
housing when closed. No need to
support luminaire while screwing the
housing to the cover . . . . . . . . . . . . . .S890
Ballast-Gard™ starter cut-out
switch – prevents starter pulsing
when lamp is cycling or inoperative;
prolongs ballast and ignitor life.
Available for use with
50–150W LX HPS only . . . . . . . . . . . .BG
Instant restrike – enables a hot HPS
lamp to immediately restrike after a
momentary loss arc due to voltage
fluctuation or power outage. It has no
effect on the warm-up period of cold
lamps.
50–150W LX HPS only . . . . . . . . . . IR
50–100W LX HPS only . . . . . . . . . . TIR
Quartz auxiliary lighting – comes to
full brightness immediately and
remains lit until the HID lamp attains
60–70% of full illumination. For nonhazardous locations only. Must use
R2, R3 and
R5 refractors. . . . . . . . . . . . . . . . . . . . .QTZ
Refractor Mount - For ballast
housing only. Used with R2, R3 and
R5 refractors. . . . . . . . . . . . . . . . . . . . .RM
Stainless steel insert – top hat with
stainless steel threaded insert to
attach ballast housing . . . . . . . . . . . . .S806
TEFLON coating on globe for
increased shatter protection . . . . . . . .S808
G24 only. T-Numbers not affected
Factory assembled with H.I.D.
lamps installed for additional labor
savings . . . . . . . . . . . . . . . . . . . . . . . .FA

Features:

3L

Cl. II, Groups E, F, G, Cl. III &
Simultaneous Presence
(HPS 50W, 70W)
Marine & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

• Compact, lightweight design is ideal for
medium and low mounting heights
• Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance
to corrosion
• Seven mounting arrangements to suit any
lighting layout – pendant, flexible pendant,
ceiling, wall bracket, angle stanchion,
straight stanchion, and quad-mount
• Wide range of light sources and wattages
to meet specifiers' needs: 50, 70, 100, and
150 watt high pressure sodium (HPS); 70,
100, 175 watt metal halide (MH and Pulse
Start MH)
• Hinged ballast housing for ease of
installation and maintenance
• Wide choice of photometric distributions.
Glass globes, refractors and compact
refractors available for all wattage
luminaires; plastic refractors (for nonhazardous applications only) for 50–100
watt luminaires
• All luminaires are designed to perform in a
40°C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C
• Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments
• Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation
• Low ambient capability to (–40°C)
• Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware.
Will not chip, peel, dent, rust, or corrode
• Grounding wire for safety
• High power factor ballasts (Min P.F. 90%)
and available in a variety of voltages to
meet local area requirements
• Mogul base porcelain lamp socket
962

www.crouse-hinds.com

US: 1-866-764-5454

Certifications and
Compliances:
• NEC & CEC:
Class I, Division 2, Groups A, B, C, D
HPS 50W, 70W – Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15

Standard Materials:
• Ballast housings and mountings –
copper-free aluminum (less than 0.4 of
1%)
• Exterior hardware – stainless steel
• Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
• Globes – heat and impact resistant
internally fluted glass
• Refractors – glass (50–175 watts); plastic
50–100 watts), for non-hazardous
applications
• Guards: Globe – copper-free aluminum
Refractor – stainless steel

Standard Finishes:
• Copper-free aluminum – epoxy powder
coat
• Krydon material – high reflectance white
• Stainless steel – natural

Note:

BG and IR options cannot be used together. IR and
QTZ options cannot be used together.

Accessories:

Electrical Ratings:

• See pages 1022–1023 for complete listing.

• 120, 208, 240, 277, 347, 480, 600, Multitap (120, 208, 240 and 277)
• 50 to 150W HPS; 70 to 175W MH

TEFLON is a registered trademark of E.I. duPont Co.

CAN: 1-800-265-0502

*When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Copyright© 2013 Eaton’s Crouse-Hinds Business

962-963.qxp

12/16/2013

7:17 PM

Page 963

VMV Series 50–150W
High Pressure Sodium
Champ® H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups E, F, G, Cl. III &
Simultaneous Presence
(50W, 70W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By
Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G24 Globe
With G241 Type I
With R5 Glass
Style
Size
Watts
and P21 Guard
Compact Refractor *
Refractor †
50

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

50

Stanchion
Mount
25° Angle

Stanchion
Mount
Straight

Flexible
Pendant Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant,
Adjustable,
Thru-Feed,
25º Angle,
12½º Angle

VMVS2A050GP
VMVS3A050GP
VMVS2A070GP
VMVS3A070GP
VMVS2A100GP
VMVS3A100GP
VMVS2A150GP
VMVS3A150GP
VMVS2HA050GP
VMVS2HA070GP
VMVS2HA100GP
VMVS2HA150GP

VMVS2A050G241
VMVS3A050G241
VMVS2A070G241
VMVS3A070G241
VMVS2A100G241
VMVS3A100G241
VMVS2A150G241
VMVS3A150G241
VMVS2HA050G241
VMVS2HA070G241
VMVS2HA100G241
VMVS2HA150G241

VMVS2A050R5
VMVS3A050R5
VMVS2A070R5
VMVS3A070R5
VMVS2A100R5
VMVS3A100R5
VMVS2A150R5
VMVS3A150R5
VMVS2HA050R5
VMVS2HA070R5
VMVS2HA100R5
VMVS2HA150R5

50
70
100
150

VMVS2C050GP
VMVS3C050GP
VMVS2C070GP
VMVS3C070GP
VMVS2C100GP
VMVS3C100GP
VMVS2C150GP
VMVS3C150GP
VMVS2TW050GP
VMVS3TW050GP
VMVS2TW070GP
VMVS3TW070GP
VMVS2TW100GP
VMVS3TW100GP
VMVS2TW150GP
VMVS3TW150GP
VMVS25Q050GP
VMVS25Q070GP
VMVS25Q100GP
VMVS25Q150GP

VMVS2C050G241
VMVS3C050G241
VMVS2C070G241
VMVS3C070G241
VMVS2C100G241
VMVS3C100G241
VMVS2C150G241
VMVS3C150G241
VMVS2TW050G241
VMVS3TW050G241
VMVS2TW070G241
VMVS3TW070G241
VMVS2TW100G241
VMVS3TW100G241
VMVS2TW150G241
VMVS3TW150G241
VMVS25Q050G241
VMVS25Q070G241
VMVS25Q100G241
VMVS25Q150G241

VMVS2C050R5
VMVS3C050R5
VMVS2C070R5
VMVS3C070R5
VMVS2C100R5
VMVS3C100R5
VMVS2C150R5
VMVS3C150R5
VMVS2TW050R5
VMVS3TW050R5
VMVS2TW070R5
VMVS3TW070R5
VMVS2TW100R5
VMVS3TW100R5
VMVS2TW150R5
VMVS3TW150R5
VMVS25Q050R5
VMVS25Q070R5
VMVS25Q100R5
VMVS25Q150R5

11/2
11/2
11/2
11/2

50
70
100
150

VMVSJ050GP
VMVSJ070GP
VMVSJ100GP
VMVSJ150GP

VMVSJ050G241
VMVSJ070G241
VMVSJ100G241
VMVSJ150G241

VMVSJ050R5
VMVSJ070R5
VMVSJ100R5
VMVSJ150R5

11/2
11/2
11/2
11/2

50
70
100
150

VMVSP050GP
VMVSP070GP
VMVSP100GP
VMVSP150GP

VMVSP050G241
VMVSP070G241
VMVSP100G241
VMVSP150G241

VMVSP050R5
VMVSP070R5
VMVSP100R5
VMVSP150R5

70
100
150
50
70
100
150

70
100
150
50
70
100
150

3L

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

Pendant Mount

* For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVS2A050G243
For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVS2A050G245
† For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVS2A050R2.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVS2A050R3.
2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps
- add suffix CE. 50W HPS luminaire is dual tap only.

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL

CEC/CSA (cUL)

Voltage
Multi Tap
Dual Tap
120V
Suffix
/MT
/DT
/120
Multi Tap and Dual Tap ballasts are powered for 277V

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

www.crouse-hinds.com

120V
/120

3. Options - Add the required option suffixes, see page 962,
in alpha-numeric order.

EXPORT

US: 1-866-764-5454

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

963

964-965.qxp

12/16/2013

3L

7:18 PM

Page 964

VMV Series 150–175W
Pulse Start Metal Halide

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Champ® H.I.D. Luminaires

To complete the catalog #, include information in note 1 below. For guards and other optics see VMV Series - Ordering By Components page.

Mounting
Style

Hub
Size

Lamp
Watts

With G24 Globe
and P21 Guard

Pendant Mount

3
/4
1
3
/4
1

150

VMVM2A150GP
VMVM3A150GP
VMVM2A175GP
VMVM3A175GP

S828
S828
S828
S828

VMVM2A150G245
VMVM3A150G245
VMVM2A175G245
VMVM3A175G245

S828
S828
S828
S828

/4
/4

150
175

VMVM2HA150GP S828
VMVM2HA175GP S828

VMVM2HA150G245 S828
VMVM2HA175G245 S828

VMVM2HA150R5 S828
VMVM2HA175R5 S828

Ceiling Mount
Thru-Feed

3
/4
1
3
/4
1

150

VMVM2C150GP
VMVM3C150GP
VMVM2C175GP
VMVM3C175GP

VMVM2C150G245
VMVM3C150G245
VMVM2C175G245
VMVM3C175G245

VMVM2C150R5
VMVM3C150R5
VMVM2C175R5
VMVM3C175R5

3
/4
1
3
/4
1

150

3

175

S828
S828
S828
S828

VMVM2TW150GP
VMVM3TW150GP
VMVM2TW175GP
VMVM3TW175GP

175

S828
S828
S828
S828

S828
S828
S828
S828

VMVM2TW150G245
VMVM3TW150G245
VMVM2TW175G245
VMVM3TW175G245

S828
S828
S828
S828

VMVM2TW150R5
VMVM3TW150R5
VMVM2TW175R5
VMVM3TW175R5

S828
S828
S828
S828

3

/4
/4

150
175

VMVM25Q150GP S828
VMVM25Q175GP S828

VMVM25Q150G245 S828
VMVM25Q175G245 S828

VMVM25Q150R5 S828
VMVM25Q175R5 S828

Stanchion
Mount
25° Angle

11/2
11/2

150
175

VMVMJ150GP S828
VMVMJ175GP S828

VMVMJ150G245 S828
VMVMJ175G245 S828

VMVMJ150R5 S828
VMVMJ175R5 S828

Stanchion
Mount
Straight

11/2
11/2

150
175

VMVMP150GP S828
VMVMP175GP S828

VMVMP150G245 S828
VMVMP175G245 S828

VMVMP150R5 S828
VMVMP175R5 S828

3

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Multi Tap
/MT

120V
/120

480V
/480

CEC/CSA (cUL)
Tri Tap
/TT

120V
/120

Optional Voltage Ballasts - 50 or 60Hz
EXPORT

964

S828
S828
S828
S828

Quad-Mount
Pendant,
Adjustable ThruFeed, 25° Angle,
121/ 2° Angle

† For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A150R2-S828.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A150R3-S828.

Voltage
Suffix

S828
S828
S828
S828

3

* For G241 Type I Compact Refractor, change "245" at end of catalog number to "241". Ex. VMVM2A150G241-S828
For G243 Type III Compact Refractor, change "245" at end of catalog number to "243". Ex. VMVM2A150G243-S828

Voltage
Suffix

VMVM2A150R5
VMVM3A150R5
VMVM2A175R5
VMVM3A175R5

Flexible
Pendant Mount

Wall Mount
Thru-Feed

3L

175

BASIC CATALOG NUMBER
With G245 Type V
With R5 Glass
Compact Refractor *
Refractor †

220V 60Hz
/220

www.crouse-hinds.com

220V 50Hz
/220 50

US: 1-866-764-5454

230V 50Hz
/230 50

CAN: 1-800-265-0502

240V 50Hz
/240 50

Copyright© 2013 Eaton’s Crouse-Hinds Business

964-965.qxp

12/16/2013

7:18 PM

Page 965

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix S826TB)

VMV Series 70–175W
Metal Halide
Champ® H.I.D. Luminaires

Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By Components page.

Mounting
Style

Hub
Size

Pendant Mount

3
/4
1
3
/4
1
3
/4
1

Lamp
Watts

With G24 Globe
and P21 Guard

BASIC CATALOG NUMBER
With G241 Type I
With R5 Glass
Compact Refractor *
Refractor †

70

VMVM2A070GP
VMVM3A070GP
VMVM2A100GP
VMVM3A100GP
VMVM2A175GP
VMVM3A175GP

VMVM2A070G241
VMVM3A070G241
VMVM2A100G241
VMVM3A100G241
VMVM2A175G241
VMVM3A175G241

VMVM2A070R5
VMVM3A070R5
VMVM2A100R5
VMVM3A100R5
VMVM2A175R5
VMVM3A175R5

100
175

Flexible
Pendant Mount

3

/4
/4
3
/4

70
100
175

VMVM2HA070GP
VMVM2HA100GP
VMVM2HA175GP

VMVM2HA070G241
VMVM2HA100G241
VMVM2HA175G241

VMVM2HA070R5
VMVM2HA100R5
VMVM2HA175R5

Ceiling Mount
Thru-Feed

3
/4
1
3
/4
1
3
/4
1

70

VMVM2C070GP
VMVM3C070GP
VMVM2C100GP
VMVM3C100GP
VMVM2C175GP
VMVM3C175GP

VMVM2C070G241
VMVM3C070G241
VMVM2C100G241
VMVM3C100G241
VMVM2C175G241
VMVM3C175G241

VMVM2C070R5
VMVM3C070R5
VMVM2C100R5
VMVM3C100R5
VMVM2C175R5
VMVM3C175R5

VMVM2TW070GP
VMVM3TW070GP
VMVM2TW100GP
VMVM3TW100GP
VMVM2TW175GP
VMVM3TW175GP

VMVM2TW070G241
VMVM3TW070G241
VMVM2TW100G241
VMVM3TW100G241
VMVM2TW175G241
VMVM3TW175G241

VMVM2TW070R5
VMVM3TW070R5
VMVM2TW100R5
VMVM3TW100R5
VMVM2TW175R5
VMVM3TW175R5

Wall Mount
Thru-Feed

Quad-Mount

3

3
/4
1
3
/4
1
3
/4
1

100
175

70
100
175

3

/4
/4
3
/4

70
100
175

VMVM25Q070GP
VMVM25Q100GP
VMVM25Q175GP

VMVM25Q070G241
VMVM25Q100G241
VMVM25Q175G241

VMVM25Q070R5
VMVM25Q100R5
VMVM25Q175R5

Stanchion
Mount
25° Angle

11/2
11/2
11/2

70
100
175

VMVMJ070GP
VMVMJ100GP
VMVMJ175GP

VMVMJ070G241
VMVMJ100G241
VMVMJ175G241

VMVMJ070R5
VMVMJ100R5
VMVMJ175R5

Stanchion
Mount
Straight

11/2
11/2
11/2

70
100
175

VMVMP070GP
VMVMP100GP
VMVMP175GP

VMVMP070G241
VMVMP100G241
VMVMP175G241

VMVMP070R5
VMVMP100R5
VMVMP175R5

3L

Pendant,
Adjustable
Thru-Feed,
25° Angle,
121/ 2° Angle

3

* For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVM2A070G243
For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVM2A070G245
† For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A070R2.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A070R3.
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz

2. 70W ballast not available in 480V.
NEC/UL

Voltage
Suffix

Multi Tap
/MT

120V
/120

480V
/480

Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

480V CWI
/240CWI

3. Options - Add the required option suffixes, see page 962,
in alpha-numeric order.

CEC/CSA (cUL)

600V CWI
/600CWI

www.crouse-hinds.com

120V
/120

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

US: 1-866-764-5454

230V 50Hz
/230 50

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

965

966-967.qxp

12/16/2013

7:18 PM

Page 966

VMV Series –
Ordering by Components

3L

VMV luminaires are available in components.
A complete luminaire consists of:
I.

Champ Cover (Mounting Module)

II.

VMV Ballast Housing – Include voltage and required option(s)

III.

Optical & Guard components – Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module):
Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

3

Flexible Pendant

3

/4"

HPM2

Ceiling

3

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion – 25 Degree Angle

11/2"

JM5

Stanchion – Straight

1 /2"

PM5

Quad-Mount

3

/4"

QM25

1

II. Ballast Housings:
Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Cat. #
For Globe and
Compact Refractor

Cat. #
For Large
Refractor

Lamp Watts

High
Pressure
Sodium

50
70
100
150

VMVS050/DT
VMVS070/MT
VMVS100/MT
VMVS150/MT LX

VMVS050/MT RM
VMVS070/MT RM
VMVS100/MT RM
VMVS150/MT LX RM

Metal
Halide

70
100
175

VMVM070/MT
VMVM100/MT
VMVM175/MT

VMVM070/TT RM
VMVM100/MT RM
VMVM175/MT RM

3L

Lamp Type

III. Globe, Reflectors, Refractors, Guards:
Type

Cat. #

Globe
Globe – Teflon Coated
Globe Guard
Reflector – Dome
Reflector – Angle
Compact Refractor Type 1
Compact Refractor Type 3
Compact Refractor Type 5
Compact Refractor Guard
Large Refractor Type 2
Large Refractor Type 3
Large Refractor Type 5
Large Refractor Guard
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

G24
G24 S808
P21
RD70
RA70

966

www.crouse-hinds.com

G241
G243
G245
P241
R2
R3
R5
P23
PR2
PR3
PR5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

966-967.qxp

12/16/2013

7:18 PM

Page 967

VMV Series

3L

Family Tree

Champ® H.I.D. Luminaires

3L

*Plastic refractors are for non-hazardous areas only (50–100W Max.)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

967

968-969.qxp

12/16/2013

7:18 PM

Page 968

Temperature Performance Data

VMV Series

3L

Champ® H.I.D. Luminaires

Rated
Ambient
°C

Lamp

Cat. #

Class II,
Division 1

Class I, Division 2
Globe
(G24,
G241,
G245)

Class I, Zone 2

Supply Wire
Suitable For °C

Globe
Globe (G24)
Restricted
(G24) w/
w/ or w/o Simultaneous Breathing Suffix
Factory
Globe
Reflector Refractor
Reflector
Presence
S826 w/
Sealed
(G24, Refractor
(RA70 or (R2, R3,
(RA70 or
Class I, Div. 2
Globe (G24,
Suffix S865 G241, (R2, R3,
RD70)
or R5)
Group
RD70)
Class II, Div. 2
G241, G245)
AEx nA nR II G245)
or R5)

Wattage

Type

VMVM70
VMVM70
VMVM70
VMVM100
VMVM100 S849
VMVM100
VMVM150
VMVM175

70
70
70
100
100
100
150
175

MH
MH
MH
MH
MH
MH
MH
MH

40
55
65
40
40
55
40
40

T3A
T3
T3
T2D
T2
T2D
T2A
T2A

T3A
T3
T3
T2D
T2
T2D
T2A
T2A

T3A
T3
T3
T2D
T2
T2D
T2B
T2B

VMVS50
VMVS50
VMVS50
VMVS70
VMVS70
VMVS100
VMVS100
VMVS150
VMVS150

50
50
50
70
70
100
100
150
150

HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS

40
55
65
40
55
40
55
40
55

T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2

T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2

T3B
T3A
T3
T3B
T3
T2D
T2C
T2B
T2A

VMVIG055
VMVIG055

55
55

Induction
Induction

40
55

T2C
T2C

T2C
T2C

—
—

EFG
EFG
EFG
EFG
EFG
EFG
EFG

T4A
T4
T4
T3C
T3C
T3A

T3A
T3
T2D
T2C
T2B
T2A

T5
T4
T4
T4
T4
T4
T3
T3

T3
T3
T3
T3
T3
T3
T3
T3

90
90
90
90
75
90
90
90

90
90
90
90
75
90
90
90

T5
T5
T5
T4
T4
T4
T3
T3
T3

T3
T3
T3
T3
T3
T3
T3
T3
T3

75
75
75
75
90
90
105
90
105

65
75
75
65
90
75
90
85
105

T6
T5

—
—

65
65

—
—

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL844 specifies how the temperatures are measured.

3L

The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC® 501.1 states that equipment "…for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations…" then these luminaires are suitable for Class I, Division 2 but with cooler temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.

968

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

968-969.qxp

12/16/2013

7:18 PM

Page 969

Dimensions and Weights

VMV Series

3L

Champ® H.I.D. Luminaires

Dimensions

Net Luminaire Weights:

In Inches:

Lamp Watts
Luminaire Series
50
70
Luminaire with Globe, Guards (lbs.):
VMVS
131/2
141/2
VMVM
13
Luminaire with Glass Refractor (lbs.):
VMVS
213/4
223/4
VMVM
21

Pendant Mount

Ceiling Mount Top View

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Flexible Pendant
11/2
Ceiling
23/4
Wall
41/2
Add for reflectors:
Dome

11/2

100

150

141/2
131/4

141/2

223/4
211/2

223/4

175

151/2

233/4

Type

Lbs.

Quad-Mount
Angle Stanchion
Straight Stanchion

31/ 2
31/ 2
41/ 2

30° Angle

11/ 2

Deduct: /2" lb. for fixture without P21 Guard
1

Quad-Mount

Ceiling Mount

25° Angle Stanchion Mount

Straight Stanchion Mount

Luminaire With: Refractors,
Guard

3L

Wall Mount

Compact Refractor

Globe, Guard, Reflectors

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

969

970-971.qxp

12/16/2013

7:18 PM

Page 970

VMV Series

3L

Photometric Data

Champ® H.I.D. Luminaires
Lamp: 100W/E – 231/2 high pressure sodium (HPS)
Total bare lamp lumens: 9500
NOTE: All data provided is for high pressure sodium luminaires with 100W/E–23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Eaton's Crouse-Hinds for additional photometric data on any Champ Series luminaire.

Luminaire with Globe and Dome Reflector
Multipliers (for use with
candela curve only).
ConLuminaire Lamp version
Series
Watts Factor
VMVS

50
70
150

Isofootcandle Chart: Luminaire with Globe and
Dome Reflector

0.42
0.67
1.68

Luminaire spacing ratio: 1.85

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

3L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.823
.784
.749

.707
.646
.594

.610
.538
.482

.529
.451
.391

.464
.384
.324

70

50
30
10

.804
.767
.734

.690
.633
.587

.597
.530
.477

.517
.445
.388

.452
.377
.321

50

50
30
10

.765
.735
.709

.658
.611
.569

.571
.513
.466

.494
.431
.381

.434
.368
.318

30

50
30
10

.731
.708
.685

.629
.591
.555

.546
.497
.456

.473
.419
.375

.416
.357
.312

10

50
30
10

.701
.681
.662

.603
.569
.541

.524
.482
.446

.454
.406
.367

.399
.348
.307

0

0

.644

.521

.427

.348

.288

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.412
.334
.278

.366
.290
.239

.326
.253
.201

.296
.224
.175

.258
.187
.142

70

50
30
10

.403
.329
.274

.359
.285
.235

.320
.250
.200

.291
.221
.174

.252
.187
.142

50

50
30
10

.386
.320
.271

.344
.277
.231

.307
.244
.197

.279
.216
.172

.244
.182
.140

30

50
30
10

.371
.312
.267

.329
.272
.227

.296
.237
.195

.269
.210
.170

.235
.178
.137

Isofootcandle charts show illumination in footcandles on work plane
10 feet below light center. Multiply by factor shown to convert to
other mounting heights.

50
30
10

.357
.304
.263

.319
.266
.224

.285
.232
.192

.260
.206
.167

.227
.173
.135

Height (Ft.)

Factor

Height (Ft.)

Factor

10

0.51
0.39

0

.245

.207

.176

.152

.120

2.78
1.56
0.70

14
16

0

6
8
12

% Reflectance
Eff. Ceil.
Wall

970

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Copyright© 2013 Eaton’s Crouse-Hinds Business

970-971.qxp

12/16/2013

7:18 PM

Page 971

VMV Series

Photometric Data

3L

Champ® H.I.D. Luminaires
Lamp: 100W/E0 – 231/2 high pressure sodium (HPS)

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

Luminaire with I.E.S. Type V Glass Refractor

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.848
.796
.750

.709
.631
.566

.597
.509
.439

.508
.414
.341

.437
.343
.271

70

Conversion
Factor

50
30
10

.818
.770
.726

.682
.611
.552

.576
.493
.428

.489
.402
.334

.419
.331
.264

50

0.42
0.67
1.68

50
30
10

.759
.720
.685

.632
.574
.521

.533
.464
.407

.451
.377
.318

.389
.312
.253

30

50
30
10

.706
.675
.645

.586
.538
.495

.493
.435
.386

.417
.354
.302

.359
.291
.240

10

50
30
10

.658
.632
.608

.544
.504
.469

.457
.408
.366

.385
.331
.286

.331
.274
.227

0

0

.581

.441

.340

.260

.203

NOTE: Photometric data was
developed using a 100 watt
clear high pressure sodium
lamp (9500 lumens). For other
clear lamps, use the following
conversion factors (multipliers):
Luminaire Lamp
Series
Watts
VMVS

50
70
150

% Reflectance
Eff. Ceil.
Wall

Luminaire spacing ratio: 2.0

% Reflectance
Eff. Ceil.
Wall

US: 1-866-764-5454

9

10

80

50
30
10

.384
.292
.226

.337
.249
.189

.299
.214
.154

.272
.189
.132

.238
.159
.103

70

50
30
10

.369
.283
.218

.325
.240
.182

.288
.203
.150

.262
.183
.130

.229
.156
.105

50

50
30
10

.341
.266
.209

.301
.225
.173

.266
.195
.143

.243
.173
.124

.214
.146
.099

30

50
30
10

.316
.249
.199

.277
.213
.163

.248
.182
.136

.225
.161
.117

.198
.136
.093

10

50
30
10

.292
.233
.188

.258
.200
.154

.223
.171
.128

.209
.151
.110

.134
.127
.087

0

0

.165

.133

.108

.091

.070

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

3L

www.crouse-hinds.com

Room Cavity Ratio
6
7
8

971

972-973.qxp

12/16/2013

7:19 PM

Page 972

LMV Series 50-150W
Low Profile Medium Base

3L

Champ® H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III
& Simultaneous Presence
(HPS 35W, 50W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

Applications:

Options:

LMV series Champ® luminaires are used:
• In applications involving low luminaire
mounting heights or restricted mounting
space or where luminaire weight is a
factor
• In areas in which ignitible concentrations
of flammable gases or vapors will be
present only due to abnormal, unusual,
or accidental conditions
• Where combustible dusts are present
• Where combustible dusts and flammable
vapors are present simultaneously
• In elevated ambient temperatures often
found in industrial applications
• In marine applications where water
spray and corrosive atmospheres are
considerations
• Wherever the damaging effects of wind,
snow, sleet, or hot sun are found
• In manufacturing plants, chemical,
petrochemical, and other industrial
process facilities, waste or sewage
treatment facilities, offshore or dockside
installations, cold storage facilities,
parking garages or wherever dust, dirt,
water, vibration and rough usage are a
problem

The following special options are available
from the factory by adding suffix to
luminaire Cat. No.:
Description
Suffix
• Restricted Breathing
Construction .............................
S826
Class I, Division 2 & Zone 2
Suitability
Cooler Operating
Temperatures (T-Numbers)
• Certified for IEC Zone 2............. S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT,
or TT)
• Fused – to protect ballast and
capacitors against abnormal
line conditions .......................... S658*
(Not for use in Canada)
(Not suitable for marine
applications)
• Quick-Clip - Holds weight of
housing when closed. No need
to support luminaire while
screwing the housing to the
cover ........................................
S890
• Ballast-Gard™ starter cut-out
switch – prevents starter
pulsing when lamp is cycling
or inoperative; prolongs ballast
and ignitor life. Available for use
with 50–100W HPS only ............
BG
• Factory assembled with H.I.D.
lamps installed for additional
labor savings .............................
FA
• Stainless steel insert – top
hat with stainless steel
threaded insert to attach
ballast housing ..........................
S806

Features:

3L

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

• Compact, lightweight design is ideal for
low mounting heights.
• Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent
resistance to corrosion.
• Seven mounting arrangements to suit
any lighting layout – pendant, flexible
pendant, ceiling, wall, straight stanchion,
angle stanchion, and quad-mount.
• Wide range of lamp wattages to meet
specifiers' needs: 50, 70, 100 and 150
watt (HPS); 70 and 100 watt (MH)
medium base lamps.
• Hinged ballast housing for ease of
installation and maintenance.
• All luminaires designed to perform in a
40°C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C.
• Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in
wet and corrosive environments.
• Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
• Low ambient capability to –40°C.
• Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity, with twist-on feature
requiring no tools or additional
hardware. Will not chip, peel, dent, rust,
or corrode.
• Grounding wire for safety.
• Medium base lamp sockets.
972

www.crouse-hinds.com

US: 1-866-764-5454

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
HPS 35W, 50W – Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15

Standard Materials:
• Ballast housings and mountings –
copper-free aluminum (less than
0.4 of 1%)
• Exterior hardware – stainless steel
• Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
• Globes – heat and impact resistant,
internally fluted glass
• Guards – copper-free aluminum

Accessories:
• See pages 1022–1023 for complete
listing

Standard Finishes:
• Copper-free aluminum – epoxy powder
coat
• Krydon material – high reflectance white
• Stainless steel – natural

Electrical Ratings:
• 120 volts, dual-tap (120/277), multi-tap*
• 50, 70, 100, 150 watts HPS**
• 70 and 100 watts MH

* When ordering fuses for luminaires, option S658, you
must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.
** 150W HPS is not avalable with multi tap ballast.
120V only.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

972-973.qxp

12/16/2013

7:19 PM

Page 973

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

LMV Series 50–150W
High Pressure Sodium
Low Profile - Medium Base
Champ® H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III
& Simultaneous Presence
(35W, 50W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G54 Globe
and P50 Guard

Pendant Mount

3

/4
1
3
/4
1
3
/4
1
3
/4
1

50

LMVS2A050GP
LMVS3A050GP
LMVS2A070GP
LMVS3A070GP
LMVS2A100GP
LMVS3A100GP
LMVS2A150GP
LMVS3A150GP

/4
/4
3
/4
3
/4

50
70
100
150

LMVS2HA050GP
LMVS2HA070GP
LMVS2HA100GP
LMVS2HA150GP

3

/4
1
/4
1
3
/4
1
3
/4
1

50

3

70

LMVS2C050GP
LMVS3C050GP
LMVS2C070GP
LMVS3C070GP
LMVS2C100GP
LMVS3C100GP
LMVS2C150GP
LMVS3C150GP

/4
1
3
/4
1
3
/4
1
3
/4
1

50

Flexible Pendant Mount

3
3

Ceiling Mount Thru-Feed

Wall Mount Thru-Feed

3

70
100
150

100
150

70
100
150

LMVS2TW050GP
LMVS3TW050GP
LMVS2TW070GP
LMVS3TW070GP
LMVS2TW100GP
LMVS3TW100GP
LMVS2TW150GP
LMVS3TW150GP

3

/4
/4
3
/4
3
/4

50
70
100
150

LMVS25Q050GP
LMVS25Q070GP
LMVS25Q100GP
LMVS25Q150GP

Stanchion Mount
25° Angle

11/2
11/2
11/2
11/2

50
70
100
150

LMVSJ050GP
LMVSJ070GP
LMVSJ100GP
LMVSJ150GP

Stanchion Mount
Straight

11/2
11/2
11/2
11/2

50
70
100
150

LMVSP050GP
LMVSP070GP
LMVSP100GP
LMVSP150GP

3

3L

Quad Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/ 2° Angle

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

120V
/120

2. 150W HPS Luminaires: For 55V lamps - add suffix LX. 50W HPS luminaire is dual tap only. 150W HPS is not avalable with multi tap ballast. 120V only.
3. Options - Add the required option suffixes, see page 972, in alpha-numeric order.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

973

974-975.qxp

12/16/2013

3L

7:19 PM

Page 974

LMV Series 70-100W
Metal Halide

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Low Profile - Medium Base
Champ® H.I.D. Luminaires

Marine & Wet Locations
3, 3R, 4, 4X; IP66

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting Style
Pendant Mount

Hub
Size

Lamp
Watts

With G54 Globe
and P50 Guard

3
/4
1
3
/4
1

70

LMVM2A070GP
LMVM3A070GP
LMVM2A100GP
LMVM3A100GP

100

/4
/4

70
100

LMVM2HA070GP
LMVM2HA100GP

3
/4
1
3
/4
1

70

LMVM2C070GP
LMVM3C070GP
LMVM2C100GP
LMVM3C100GP

3
/4
1
3
/4
1

70

Stanchion Mount
25° Angle

11/2
11/2

70
100

LMVMJ070GP
LMVMJ100GP

Stanchion Mount
Straight

11/2
11/2

70
100

LMVMP070GP
LMVMP100GP

3

Flexible Pendant Mount

3

Ceiling Mount
Thru-Feed

LMVM2TW070GP
LMVM3TW070GP
LMVM2TW100GP
LMVM3TW100GP

100

3L

Wall Mount Thru-Feed

100

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

120V
/120

2. 70W ballast not available in 480V.
3. Options - Add the required option suffixes, see page 972, in alpha-numeric order.

974

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

974-975.qxp

12/16/2013

7:19 PM

Page 975

LMV Series – Ordering by Components

3L

LMV luminaires are available in components.
A complete luminaire consists of:
I.
II.
III.

Champ Cover (Mounting Module)
LMV Ballast Housing – Include voltage and required option(s)
Globe, Guard, Reflector

I. Champ Cover (Mounting Module):
Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

3

Flexible Pendant

3

/4"

HPM2

Ceiling

3

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion – 25 Degree Angle

11/2"

JM5

Stanchion – Straight

1 /2"

PM5

Quad-Mount

3

/4"

QM25

1

II. Ballast Housings:
Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
Lamp Watts
Cat. #
High Pressure Sodium

50
70
100
150

LMVS050/120
LMVS070/MT
LMVS100/MT
LMVS150/120 LX

Metal Halide

70
100

LMVM070/MT
LMVM100/MT

Type

Cat. #

Globe
Globe Guard
Reflector – Dome
Reflector – Angle

G54
P50
RD636
RA636

www.crouse-hinds.com

US: 1-866-764-5454

3L

III. Globe, Guards and Reflectors:

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

975

976-977.qxp

3L

12/16/2013

7:19 PM

Page 976

LMV Series

Family Tree

3L

Champ® H.I.D. Luminaires

976

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

976-977.qxp

12/16/2013

7:19 PM

Page 977

LMV Series

Temperature Performance Data

3L

Champ® H.I.D. Luminaires
Rated
Ambient
°C

Lamp

Cat. #

Wattage

Type

LMVS50
LMVS50
LMVS50
LMVS70
LMVS70
LMVS100
LMVS100

50
50
50
70
70
100
100

HPS
HPS
HPS
HPS
HPS
HPS
HPS

LMVM70
LMVM70
LMVM100

70
70
100

LMVM150

150

40
55
65
40
55
40

Class I,
Division 2
Globe (G54)
w/ or w/o
Reflector
(RA636 or
RD636)

Class II, Division 1
Globe (G54)
w/ or w/o
Reflector
(RA636 or
Group
RD636)

Simultaneous
Presence
Class I, Div. 2
Class II, Div. 1

Class I, Zone 2
Restricted
Factory
Breathing
Sealed
Suffix
Suffix
S826 w/
S865
Globe (G24) AEx nA nR II

Supply
Wire
Suitable
for °C

50

T2D
T2C
T2C
T2B
T2B
T2
—

EFG
—
—
—
—
—
—

T3C
—
—
—
—
—
—

T2B
—
—
—
—
—
—

T5
T4
T4
T4
T4
T4
T3

T3
T3
T3
T3
T3
T3
T3

N/A
75
85
75
85
85
90

MH
MH
MH

40
55
40

T2B
T2B
—

—
—
—

—
—
—

—
—
—

T4
T4
T3

T3
T3
T3

75
85
85

HPS

40

T1 350°C

—

—

—

—

—

85

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL 844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC® 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

977

978-979.qxp

12/16/2013

7:19 PM

Page 978

LMV Series

3L

Dimensions and Weights

Champ® H.I.D. Luminaires
Dimensions

Luminaire Net Weights:

In Inches:
Luminaire
Series
LMVS

LMVM
Pendant Mount

Luminaire
with Globe,
Guard (lbs.)

50
70
100
150

73/4
81/4
83/4
91/4

70
100

9
9

Type
Add for mounting modules:
Pendant
Flexible Pendant
Ceiling
Quad-Mount
Wall
Angle Stanchion
Straight Stanchion

Top View

Wall Mount

Lamp
Watts

Ceiling Mount

Type
Add for reflectors:
Dome
30° Angle
Deduct for luminaire without guard:
P50 Guard

Luminaire with Globe, Guard,
Reflectors

Straight Stanchion Mount

25° Angle Stanchion Mount

3L

Quad-Mount

978

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Lbs.
11/4
11/2
23/4
31/2
41/2
31/2
41/2
lbs.
1.0
1.0
/2

1

978-979.qxp

12/16/2013

7:19 PM

Page 979

Photometric Data

LMV Series

3L

Champ® H.I.D. Luminaires
Lamp: 100W/E-17 high pressure sodium (HPS)
Total bare lamp lumens: 9500
All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use conversion factors (multipliers) shown below for other lamp types and wattages. Consult Eaton's
Crouse-Hinds for additional photometric data on any Champ Series.

Luminaire with Globe and Dome Reflector
Multipliers (for use with candela
curve only).
ConLuminaire Lamp
version
Series
Watts Factor
35
50
70
150

LMVS

Isofootcandle Chart: Luminaire with Globe
and Dome Reflector

0.24
0.42
0.67
1.68

Luminaire spacing ratio: 2.0

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.

Room Cavity Ratio
1

2

3

4

5

80

50
30
10

.722
.691
.663

.628
.579
.537

.545
.487
.441

.473
.408
.358

.413
.346
.296

70

50
30
10

.705
.676
.650

.613
.568
.531

.534
.479
.436

.463
.403
.355

.403
.340
.293

50

50
30
10

.671
.647
.627

.585
.548
.514

.511
.464
.426

.442
.390
.349

.387
.332
.289

30

50
30
10

.641
.623
.605

.560
.529
.501

.489
.450
.416

.424
.379
.342

.371
.322
.284

10

50
30
10

.614
.598
.584

.537
.510
.488

.470
.436
.407

.407
.367
.335

.356
.341
.279

0

0

.568

.471

.391

.319

.263

Wall

6

7

8

9

10

80

50
30
10

.366
.300
.253

.324
.259
.215

.288
.225
.180

.261
.199
.156

.226
.165
.127

70

50
30
10

.358
.295
.249

.318
.255
.212

.282
.223
.179

.256
.196
.156

.221
.165
.126

50

50
30
10

.343
.288
.246

.305
.248
.209

.271
.217
.177

.246
.192
.154

.214
.161
.124

30

50
30
10

.330
.280
.242

.292
.243
.205

.261
.210
.175

.237
.186
.152

.206
.157
.122

10

50
30
10

.317
.272
.238

.282
.237
.202

.251
.206
.172

.228
.182
.149

.199
.152
.120

0

0

.223

.187

.158

.136

.107

% Reflectance
Eff. Ceil

Isofootcandle Chart: Luminaire with Globe
and 30° Angle Reflector

3L

Wall

Room Cavity Ratio

www.crouse-hinds.com

US: 1-866-764-5454

Isofootcandle charts show illumination in footcandles on work plane
10 feet below light center. Multiply by factor shown to convert to
other mounting heights.
Height (Ft.)

Factor

Height (Ft.)

Factor

6
8
12

2.78
1.56
0.70

14
16

0.51
0.39

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

979

980-981.qxp

12/16/2013

7:20 PM

Page 980

DMV Series 50-250W
For Combustible Dusts

3L

Champ® H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

Applications:

Options:

DMV series Champ luminaires are used:

The following special options are available
from the factory by adding suffix to luminaire
Cat. No.:

• In applications made hazardous by the
presence of combustible dusts
• In areas in which ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or
accidental conditions
• In marine applications where water spray
and corrosive atmospheres are
considerations
• In areas where combustible dusts and
flammable vapors are present
simultaneously
• In elevated ambient temperatures often
found in industrial applications
• In installations where moisture, dirt, dust,
vibration, corrosion and rough usage are
problems
• Wherever the damaging effects of wind,
snow, sleet, or hot sun are found
• In grain handling, storage and processing
plants, coal preparation plants, coal
conveying areas, food processing plants,
manufacturing plants, refineries, chemical,
petrochemical, and other industrial process
facilities, waste or sewage treatment
facilities, offshore, dockside, and harbor
installations, and other heavy industrial
applications

Features:

3L

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

• Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance
to corrosion.
• Seven mounting arrangements to suit any
lighting layout – pendant, flexible pendant,
ceiling, wall bracket, angle stanchion,
straight stanchion, and quad-mount.
• Wide range of light sources and wattages
to meet specifiers' needs: 50, 70, 100, 150
watt high pressure sodium (HPS); 70, 100,
175, 250 watt metal halide.
• Hinged ballast housing for ease of
installation and maintenance.
• All luminaires designed to perform in a
40°C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C.
• Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments.
• Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
• Low ambient capability to (–40°C.)
• Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware.
Will not chip, peel, dent, rust, or corrode.
• Mogul base porcelain lamp socket.
• Stainless steel open bottom guard permits
direct access to the globe for easy
relamping.

980

www.crouse-hinds.com

US: 1-866-764-5454

Description

• Grounding wire for safety.
• Ballasts available in voltages of 120, 208,
240, 277, 347, 480, 600 and multi-tap.*

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
175W max – Class II, Class III &
Simultaneous Presence (Class I, Division 2
and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15

Standard Materials:
• Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1% copper)
• Guard and exterior hardware – stainless
steel
• Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
• Globes – heat and impact resistant,
internally fluted glass

Standard Finishes:
• Copper-free aluminum – epoxy powder
coat
• Krydon material – high reflectance white
• Stainless steel – natural

Electrical Ratings:
• 120, multi-tap* (120, 208, 240 and 277),
tri-tap (120, 277, 347) 480, 600 volts
• 50–250W HPS; 70–250W MH

CAN: 1-800-265-0502

Suffix

• Restricted Breathing Construction . . . S826
Class I, Division 2 & Zone 2
Suitabilty
Cooler Operating Temperatures
(T-Numbers)
• Restricted Breathing/Non-Sparking . . S865
Class I, Division 2 & Zone 2
Provides T3 code without conduit
or cable seals
• Certified for IEC Zone 2 . . . . . . . . . . S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT or TT)
• Fused – to protect ballast and
capacitors against abnormal line
conditions . . . . . . . . . . . . . . . . . . . . S658*
(Not available with /MT Ballast)
(Not for use in Canada)
(Not suitable for marine applications)
• Quick-Clip - Holds weight of
housing when closed. No need to
support luminaire while screwing
the housing to the cover . . . . . . . . . S890
• Ballast-Gard™ starter cut-out
switch – prevents starter pulsing
when lamp is cycling or inoperative;
prolongs ballast and ignitor life.
Available for use with 50–150W LX
HPS only . . . . . . . . . . . . . . . . . . . . . BG
• Instant restrike – enables a hot HPS
lamp to immediately restrike after a
momentary loss of arc due to
voltage fluctuation or power outage.
It has no effect on the warm-up
period of cold lamps.
50–150W LX HPS only . . . . . . . . . IR
50–100W LX HPS only . . . . . . . . . TIR
• Quartz auxiliary lighting – comes
to full brightness immediately and
remains lit until the HID lamp attains
60–70% of full illumination. For
non-hazardous locations only.
(Note: QTZ lamp not included; use
100W single ended lamp – Q100DC,
Q100CL/DC, or 100Q/CL/DC)
Consult factory for top-hat
limitations . . . . . . . . . . . . . . . . . . . . . QTZ
• Factory assembled with H.I.D.
lamps installed for additional labor
savings . . . . . . . . . . . . . . . . . . . . . . . FA
• TEFLON® coated globe for additional
protection against breakage. For use
with 50–150W HPS and 70–175W
MH (G303 only) . . . . . . . . . . . . . . . . . S808
Note:

Some T-numbers (operating temperatures) change.
See "Temperature Performance Data" section.

• Stainless steel insert – top hat with
stainless steel threaded insert to
attach ballast housing . . . . . . . . . . . S806
Note:

BG and IR options cannot be used together. IR
and QTZ options cannot be used together.

Accessories:
• See pages 1022–1023 for complete listing.
TEFLON is a registered trademark of E.I. duPont Co.
*When ordering fuses for luminaires, option S658, you
must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.

Copyright© 2013 Eaton’s Crouse-Hinds Business

980-981.qxp

12/16/2013

7:20 PM

Page 981

DMV Series 50-150W
High Pressure Sodium
For Combustible Dust Applications
Champ® H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix
S826TB)

Cl. II, Groups E, F, G; Cl. III
& Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G303 Globe
With GR305 Glass
Style
Size
Watts
and P33 Guard
Refractor *
Pendant Mount

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

50

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

50

Stanchion Mount
25° Angle

Stanchion Mount
Straight

Flexible Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant,
Adjustable Thru-Feed,
25° Angle, 121/ 2° Angle

DMVS2A050GP
DMVS3A050GP
DMVS2A070GP
DMVS3A070GP
DMVS2A100GP
DMVS3A100GP
DMVS2A150GP
DMVS3A150GP
DMVS2HA050GP
DMVS2HA070GP
DMVS2HA100GP
DMVS2HA150GP

DMVS2A050GR305
DMVS3A050GR305
DMVS2A070GR305
DMVS3A070GR305
DMVS2A100GR305
DMVS3A100GR305
DMVS2A150GR305
DMVS3A150GR305
DMVS2HA050GR305
DMVS2HA070GR305
DMVS2HA100GR305
DMVS2HA150GR305

50
70
100
150

DMVS2C050GP
DMVS3C050GP
DMVS2C070GP
DMVS3C070GP
DMVS2C100GP
DMVS3C100GP
DMVS2C150GP
DMVS3C150GP
DMVS2TW050GP
DMVS3TW050GP
DMVS2TW070GP
DMVS3TW070GP
DMVS2TW100GP
DMVS3TW100GP
DMVS2TW150GP
DMVS3TW150GP
DMVS25Q050GP
DMVS25Q070GP
DMVS25Q100GP
DMVS25Q150GP

DMVS2C050GR305
DMVS3C050GR305
DMVS2C070GR305
DMVS3C070GR305
DMVS2C100GR305
DMVS3C100GR305
DMVS2C150GR305
DMVS3C150GR305
DMVS2TW050GR305
DMVS3TW050GR305
DMVS2TW070GR305
DMVS3TW070GR305
DMVS2TW100GR305
DMVS3TW100GR305
DMVS2TW150GR305
DMVS3TW150GR305
DMVS25Q050GR305
DMVS25Q070GR305
DMVS25Q100GR305
DMVS25Q150GR305

11/2
11/2
11/2
11/2

50
70
100
150

DMVSJ050GP
DMVSJ070GP
DMVSJ100GP
DMVSJ150GP

DMVSJ050GR305
DMVSJ070GR305
DMVSJ100GR305
DMVSJ150GR305

11/2
11/2
11/2
11/2

50
70
100
150

DMVSP050GP
DMVSP070GP
DMVSP100GP
DMVSP150GP

DMVSP050GR305
DMVSP070GR305
DMVSP100GR305
DMVSP150GR305

70
100
150
50
70
100
150

70
100
150
50
70
100
150

3L

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVS2A050GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVS2A050GR303
2. 150W HPS Luminaires: For 55V lamps - add suffix LX;
for 100V lamps - add suffix CE. 50W HPS luminaire
is dual tap only.

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

www.crouse-hinds.com

120V
/120

3. Options - Add the required option suffixes,
see page 980, in alpha-numeric order.

EXPORT

US: 1-866-764-5454

230V 50Hz
/230 50

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

981

982-983.qxp

12/16/2013

7:20 PM

Page 982

3L DMV Series - 150-250W
Pulse Start Metal Halide

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

For Combustible Dust Applications
Champ® H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see DMV Series - Ordering By Components page.

Mounting
Style

Lamp
Watts

With G303 Globe
and P33 Guard

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

150

DMVM2A150GP S828
DMVM3A150GP S828
DMVM2A175GP S828
DMVM3A175GP S828
DMVM2A200GP S828
DMVM3A200GP S828
DMVM2A250GP S828
DMVM3A250GP S828
DMVM2HA150GP S828
DMVM2HA175GP S828
DMVM2HA200GP S828
DMVM2HA250GP S828

DMVM2A150GR305 S828
DMVM3A150GR305 S828
DMVM2A175GR305 S828
DMVM3A175GR305 S828
DMVM2A200GR305 S828
DMVM3A200GR305 S828
DMVM2A250GR305 S828
DMVM3A250GR305 S828
DMVM2HA150GR305 S828
DMVM2HA175GR305 S828
DMVM2HA200GR305 S828
DMVM2HA250GR305 S828

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

150

150
175
200
250

DMVM2C150GP S828
DMVM3C150GP S828
DMVM2C175GP S828
DMVM3C175GP S828
DMVM2C200GP S828
DMVM3C200GP S828
DMVM2C250GP S828
DMVM3C250GP S828
DMVM2TW150GP S828
DMVM3TW150GP S828
DMVM2TW175GP S828
DMVM3TW175GP S828
DMVM2TW200GP S828
DMVM3TW200GP S828
DMVM2TW250GP S828
DMVM3TW250GP S828
DMVM25Q150GP S828
DMVM25Q175GP S828
DMVM25Q200GP S828
DMVM25Q250GP S828

DMVM2C150GR305 S828
DMVM3C150GR305 S828
DMVM2C175GR305 S828
DMVM3C175GR305 S828
DMVM2C200GR305 S828
DMVM3C200GR305 S828
DMVM2C250GR305 S828
DMVM3C250GR305 S828
DMVM2TW150GR305 S828
DMVM3TW150GR305 S828
DMVM2TW175GR305 S828
DMVM3TW175GR305 S828
DMVM2TW200GR305 S828
DMVM3TW200GR305 S828
DMVM2TW250GR305 S828
DMVM3TW250GR305 S828
DMVM25Q150GR305 S828
DMVM25Q175GR305 S828
DMVM25Q200GR305 S828
DMVM25Q250GR305 S828

Stanchion Mount
25° Angle

11/2
11/2
11/2
11/2

150
175
200
250

DMVMJ150GP
DMVMJ175GP
DMVMJ200GP
DMVMJ250GP

S828
S828
S828
S828

DMVMJ150GR305
DMVMJ175GR305
DMVMJ200GR305
DMVMJ250GR305

S828
S828
S828
S828

Stanchion Mount
Straight

11/2
11/2
11/2
11/2

150
175
200
250

DMVMP150GP
DMVMP175GP
DMVMP200GP
DMVMP250GP

S828
S828
S828
S828

DMVMP150GR305
DMVMP175GR305
DMVMP200GR305
DMVMP250GR305

S828
S828
S828
S828

Pendant Mount

Flexible
Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/ 2° Angle

3L

BASIC CATALOG NUMBER
With GR305 Glass
Refractor *

Hub
Size

175
200
250
150
175
200
250

175
200
250
150
175
200
250

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A150GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A150GR303-S828

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)

120V
/120

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

120V
/120

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

2. Options - Add the required option suffixes, see page 980, in alpha-numeric order.

982

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

982-983.qxp

12/16/2013

7:20 PM

Page 983

DMV Series 70–250W
Metal Halide

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

For Combustible Dust Applications
Champ® H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
With GR305 Glass
Refractor *

Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe
and P33 Guard

Pendant Mount

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

70

DMVM2A070GP
DMVM3A070GP
DMVM2A100GP
DMVM3A100GP
DMVM2A175GP
DMVM3A175GP
DMVM2A250GP
DMVM3A250GP
DMVM2HA070GP
DMVM2HA100GP
DMVM2HA175GP
DMVM2HA250GP

DMVM2A070GR305
DMVM3A070GR305
DMVM2A100GR305
DMVM3A100GR305
DMVM2A175GR305
DMVM3A175GR305
DMVM2A250GR305
DMVM3A250GR305
DMVM2HA070GR305
DMVM2HA100GR305
DMVM2HA175GR305
DMVM2HA250GR305

3

/4
1
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

70

3

100

70
100
175
250

DMVM2C070GP
DMVM3C070GP
DMVM2C100GP
DMVM3C100GP
DMVM2C175GP
DMVM3C175GP
DMVM2C250GP
DMVM3C250GP
DMVM2TW070GP
DMVM3TW070GP
DMVM2TW100GP
DMVM3TW100GP
DMVM2TW175GP
DMVM3TW175GP
DMVM2TW250GP
DMVM3TW250GP
DMVM25Q070GP
DMVM25Q100GP
DMVM25Q175GP
DMVM25Q250GP

DMVM2C070GR305
DMVM3C070GR305
DMVM2C100GR305
DMVM3C100GR305
DMVM2C175GR305
DMVM3C175GR305
DMVM2C250GR305
DMVM3C250GR305
DMVM2TW070GR305
DMVM3TW070GR305
DMVM2TW100GR305
DMVM3TW100GR305
DMVM2TW175GR305
DMVM3TW175GR305
DMVM2TW250GR305
DMVM3TW250GR305
DMVM25Q070GR305
DMVM25Q100GR305
DMVM25Q175GR305
DMVM25Q250GR305

Stanchion Mount
25° Angle

11/2
11/2
11/2
11/2

70
100
175
250

DMVMJ070GP
DMVMJ100GP
DMVMJ175GP
DMVMJ250GP

DMVMJ070GR305
DMVMJ100GR305
DMVMJ175GR305
DMVMJ250GR305

Stanchion Mount
Straight

11/2
11/2
11/2
11/2

70
100
175
250

DMVMP070GP
DMVMP100GP
DMVMP175GP
DMVMP250GP

DMVMP070GR305
DMVMP100GR305
DMVMP175GR305
DMVMP250GR305

Flexible
Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/2° Angle

100
175
250
70
100
175
250

175
250
70
100
175
250

3L

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A070GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A070GR303
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts - 175W and 250W MH only
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. 70W ballast not available in 480V.
3. Options - Add the required option suffixes, see page 980, in alpha-numeric order.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

983

984-985.qxp

12/16/2013

7:20 PM

Page 984

DMV Series –
Ordering by Components

3L

DMV luminaires are available in components.
A complete luminaire consists of:
I.
Champ Cover (Mounting Module)
II.
DMV Ballast Housing – Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector

I. Champ Cover (Mounting Module):
Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

3

Flexible Pendant

3

/4"

HPM2

Ceiling

3

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion – 25 Degree Angle

11/2"

JM5

Stanchion – Straight

11/2"

PM5

Quad-Mount

3

/4"

QM25

II. Ballast Housings:
Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Cat. #
DMVS050/MT
DMVS070/MT
DMVS100/MT
DMVS150/MT LX

70
100
175
250

DMVM070/MT
DMVM100/MT
DMVM175/MT
DMVM250/MT

3L

Metal Halide

Lamp Watts
50
70
100
150

III. Globe, Reflectors, Refractors, Guards:
Type

Cat. #

Globe

G303

Globe – Teflon Coated

G303S808

Globe Guard

P33

Reflector – Dome

RD739

Reflector – Angle

RA739

Refractor – Type 2

GR302

Refractor – Type 3
Refractor – Type 5

GR303

Large Plastic Refractor Type 2

PGR302

Large Plastic Refractor Type 3

PGR303

Large Plastic Refractor Type 5

PGR305

Refractor Guard

P23

High Bay Reflector/Lens

GRD4

984

www.crouse-hinds.com

GR305

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

984-985.qxp

12/16/2013

7:20 PM

Page 985

DMV Series

3L

Family Tree

Champ® H.I.D. Luminaires

3L

*Plastic refractors are non-hazardous areas only (50-100W Max.)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

985

986-987.qxp

12/16/2013

3L

7:21 PM

Page 986

DMV Series

Temperature Performance Data

Champ® H.I.D. Luminaires
Rated
Ambient
°C

Lamp

Class II, Division 1

Class I, Zone 2

Cat. #
DMVS50
DMVS50
DMVS50
DMVS70
DMVS70
DMVS70
DMVS100
DMVS100
DMVS100
DMVS150
DMVS150
DMVS150

Wattage
50
50
50
70
70
70
100
100
100
150
150
150

Type
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS

40
55
65
40
55
65
40
55
65
40
55
65

DMVM70
DMVM70
DMVM70
DMVM100
DMVM100
DMVM100
DMVM150
DMVM150
DMVM150
DMVM175
DMVM175
DMVM175
DMVM175
DMVM175
DMVM175
DMVM200
DMVM200
DMVM250
DMVM250

70
70
70
100
100
100
150
150
150
175
175
175
175
175
175
200
200
250
250

MH
MH
MH
MH
MH
MH
MH PS
MH PS
MH PS
MH
MH
MH
MH PS
MH PS
MH PS
MH
MH
MH
MH

40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
40
55

T3C*
T3B*
T3A*
T3*
T3*
T2D*
T2B
T2A
T2A
T2B*
T2A*
T2A*
T2B*
T2A*
T2A*
T2
T1 (325)
T2
T1 (325)

T3C
T3C
T3A
T3A
T3A
T2D
—
—
—
T2
T2
T2
—
—
—
—
—
—
—

T3C
—
—
T3C
—
—
T4A
T4
T4
T3C
—
—
T4A
T4
T4
—
—
—
—

—
—
—
—
—
—
T4A
T4
T4
T3C
—
—
T4A
T4
T4
—
—
—
—

—
—
—
—
—
—
—
—
—
T2A
—
—
—
—
—
—
—
—
—

T6
T5
T5
T5
T5
T4
T4
T4
T4
T4
T4
T3
T4
T4
T4
T4
T3
T4
T3

T6
T5
T5
T5
T5
T4
T4
T4
T4
T4
T4
T3
T4
T4
T4
T4
T3
T4
T3

T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3

90
90
90
90
90
90
105
105
105
90
90
90
105
105
105
90
90
90
90

2 / 26 (52)
2 / 32 (64)
2 / 42 (84)

CF
CF
CF

40
40
40

T3
T3
T3A

—
—
—

T6
T6
T4A

—
T6
T4A

—
—
—

T6
T6
T4

T6
T6
T4

T3
T3
—

90
90
90

85
85
165

Induction
Induction
Induction

40
55
40

T3
T2D
T3

T3
T2D
—

T5
T4A
T2D

T5
T4A
—

—
—
T2D

T6
T5
T5

T6
T5
—

T5
T4
—

90
90
90

DMVF52
DMVF64
DMVF84

3L

Class I, Division 2
Globe
(G303)
w/ or w/o
Reflector
(RA739 or
RD739)*
T3A
T3
T3
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A

DMVIG85
DMVIG85
DMVIG165

Refractor
(GR302 or
GR303 or
GR305)
T3A
T3
T3
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2B

Refractor
(G302 or
G303 or
G305) or
Globe
(G303)†
T6
T5
T4A
T6
T5
T4A
T5
T4A
—
T3C
—
—

Globe
(G303)
with
Reflector
(RA739 or
RD739)
T6
T5
T4A
T6
T5
T4A
T5
T4A
—
T3C
—
—

Simultaneous
Presence
Class I, Div. 2
Class II, Div. 1
(with G303
Globe only)
T3A
T3
T3
T3A
T3
T3
T3D
T2C
—
T2A
—
—

Restricted
Breathing
Suffix
S826 w/
Globe
(G303)
T6
T5
T5
T6
T5
T5
T6
T5
T4
T5
T4
—

Globe
(G303)
Factory
with
Sealed
Supply
Reflector
Suffix
Wire
(RA739 or S865 AEx Suitable
RD739)
nA nR II
for °C
T6
T3
90
T5
T3
90
T5
T3
90
T6
T3
90
T5
T3
90
T5
T3
90
T6
T3
90
T5
T3
90
T4
T3
90
T5
T3
90
T4
T3
90
—
T3
90

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL 844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC® 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.
*All DMVM 175W and below MH luminaires provided with Catalog number G303-S808 have a T2A T-code.
†For use with refractor only when this table indicates by means of a T-code that the refractor is suitable for use with Class I, Division 2 luminaires.

986

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

986-987.qxp

12/16/2013

7:21 PM

Page 987

Dimensions & Weights

DMV Series

3L

Champ® H.I.D. Luminaires
Net Luminaire Weights (lbs.):

Dimensions
In Inches:

Pendant Mount

Quad-Mount

Luminaire
Series

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

DMVS

50
100

23
241/16

70
150

231/16
261/8

DMVM

70
175

21
221/4

100
250

211/16
24

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Ceiling
23/4
Quad Mount
31/2
Straight Stanchion
41/2

Type

Lbs.

Flexible Pendant
Wall
Angle Stanchion

11/2
41/2
31/2

Add for reflectors:
30° Angle
Dome
11/4
Deduct: 1 lb. for luminaire without P33 Guard.
Add: 51/2 lbs. for luminaire with GR305 refractor.

25° Angle
Stanchion Mount

Straight Stanchion Mount

Top View

Ceiling Mount

13/4

3L

Wall Mount

Luminaire with Globe, Guard, Reflectors

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

987

988-989.qxp

12/16/2013

7:21 PM

Page 988

Photometric Data

DMV Series

3L

Champ® H.I.D. Luminaires
Lamp: 150W/E–23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
NOTE: All data provided is for high pressure sodium luminaires with 150W/E–23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Eaton's Crouse-Hinds for additional photometric data on any Champ series luminaires.

Luminaire with Globe and Dome Reflector
Multipliers (for use with candela
curve only).
ConLuminaire Lamp
version
Series
Watts Factor
50
70
100

DMVS

Isofootcandle Chart: Luminaire with Globe and
Dome Reflector

0.25
0.40
0.59

Luminaire spacing ratio: 1.90

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

3L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.759
.719
.683

.643
.582
.530

.551
.480
.424

.476
.400
.342

.418
.340
.283

70

50
30
10

.740
.703
.669

.627
.570
.523

.538
.471
.418

.465
.394
.338

.406
.334
.280

50

50
30
10

.703
.672
.645

.595
.548
.506

.512
.455
.408

.442
.381
.332

.388
.324
.276

30

50
30
10

.669
.646
.622

.567
.528
.492

.488
.439
.399

.422
.368
.325

.370
.314
.270

10

50
30
10

.640
.619
.600

.541
.508
.479

.466
.424
.389

.403
.356
.318

.354
.305
.265

0

0

.582

.459

.370

% Reflectance
Eff. Ceil.
Wall

.299

.247

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.371
.296
.243

.330
.257
.208

.294
.224
.174

.267
.198
.151

.231
.164
.121

70

50
30
10

.362
.291
.238

.323
.252
.204

.288
.221
.173

.262
.195
.151

.226
.164
.121

50

50
30
10

.345
.283
.235

.309
.244
.201

.275
.215
.170

.250
.190
.148

.218
.159
.119

30

50
30
10

.331
.275
.231

.294
.239
.196

.265
.208
.168

.240
.184
.146

.209
.154
.116

10

50
30
10

.317
.266
.227

.284
.233
.193

.253
.203
.165

.231
.180
.143

.201
.150
.114

0

0

.210

.177

.149

.128

.100

988

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane
10 feet below light center. Multiply by factor shown to convert to
other mounting heights.
Height (Ft.)

Factor

Height (Ft.)

Factor

8
12
14

1.56
.694
.510

16
20

.391
.250

Copyright© 2013 Eaton’s Crouse-Hinds Business

988-989.qxp

12/16/2013

7:21 PM

Page 989

VMV High Wattage Series
200-400W For Medium and
High Mounting Heights

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP66

Champ® H.I.D. Luminaires
Applications:

Standard Materials:

VMV high wattage series Champ luminaires are used:
• In manufacturing plants, refineries, chemical, petrochemical, and
other industrial process facilities, waste or sewage treatment
facilities, and other heavy industrial applications
• In applications involving medium and high mounting heights
• In applications where energy-efficient, high lumen output is
required
• In areas in which ignitible concentrations of flammable gases or
vapors will be present only due to abnormal, unusual, or accidental
conditions
• In marine applications where water spray and corrosive
atmospheres are considerations
• In elevated ambient temperatures often found in industrial
applications
• In installations where moisture, dirt, dust, vibration, corrosion and
rough usage are problems
• Wherever the damaging effects of water, wind, snow, sleet, hot
sun, or any combination of these elements, are problems

• Ballast housings and mountings –
copper-free aluminum (less than 0.4
of 1%)
• Exterior hardware and guards –
stainless steel
• Reflectors (dome and angle) –
Krydon fiberglass-reinforced
polyester material
• Globes – heat and impact resistant
internally fluted glass
• Refractors – glass
• Reflector lens – spun Alzak
aluminum, tempered glass, stainless
steel door frame

Features:

Certifications and Compliances:
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
With Glass Refractor - Class II, Class III & Simultaneous Presence
(Class I, Division 2 and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15
www.crouse-hinds.com

US: 1-866-764-5454

Standard Finishes:
•
•
•
•

Copper-free aluminum – epoxy powder coat
Alzak aluminum – natural
Stainless steel – natural
Krydon material – high reflectance white

Options:
The following special options are available from the factory by
adding suffix to luminaire Cat. No.:
Description
Suffix
• Restricted Breathing Construction...................................
S826‡
Class I, Division 2 & Zone 2 Suitability
Cooler Operating Temperatures (T-Numbers)
• Certified for IEC Zone 2.................................................... S826TB‡
Furnished with terminal block crimp terminals and
dedicated voltage ballasts (no MT, DT, or TT)
• Fused – to protect ballast and capacitors against
abnormal line conditions
(Not available with /MT ballast)
(Not suitable for marine applications)................................ S658†*
• Quick-Clip - Holds weight of housing when closed.
No need to support luminaire while screwing the
housing to the cover..........................................................
S890
• Quartz auxilliary lighting – comes to full brightness
immediately and remains lit until the HID lamp attains
60–70% of full illumination. For non-hazardous locations
only.....................................................................................
QTZ
• Ballast-Gard™ starter cutout switch – prevents starter
pulsing when lamp is cycling or inoperative; prolongs
ballast and ignitor life. Available for use with 200–400W
HPS only............................................................................
BG
• Factory assembled with H.I.D. lamps installed for
additional labor savings.....................................................
FA
• Top hat with stainless steel threaded insert to attach
ballast housing...................................................................
S806
Note:

(Quartz lamp not included use 100W single ended lamp – Q100DC,
Q100CL/DC, or 100Q/CL/DC). Consult factory for top-hat limitations.

Electrical Ratings:
• 120 to 600 volts and multi-tap
• 200, 250, 400W HPS and MH

Accessories:
• See pages 1022–1023 for complete listing.
Alzak is a registered trademark of ALCOA.
*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.
†Not for use in Canada.
‡Suffix S826 and S826TB cannot be used with GRD4 Reflector/Lens.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

989

3L

• Cast copper-free aluminum construction (less than 0.4 of 1%
copper) and epoxy powder finish provide excellent resistance to
corrosion
• Six mounting arrangements to suit any lighting layout – pendant, ceiling,
wall bracket, angle stanchion, straight stanchion and quad-mount
• Wide range of light sources and wattages to meet specifiers'
needs: 200, 250, 400 watt high pressure sodium (HPS); 250 and
400 watt metal halide (MH) and pulse start metal halide
• Hinged ballast housing for ease of installation and maintenance
• Wide choice of photometric distributions. Glass globes, glass
refractors, and reflector/lens are available
• All luminaires designed to perform in a 40°C ambient temperature.
Selected luminaires are suitable for ambient temperatures up to 65°C
• Superior gasketing seals between the mounting module, housing,
and optical assembly for optimum performance in wet and
corrosive environments
• Hubs with integral conduit stop and bushing to help prevent
damage to field wiring during installation
• Low ambient capability to (–40°C)
• Dome and 30° angle reflectors made of bright white Krydon®
material and etched Alzak® high bay reflectors provide superior
reflectivity
• Grounding wire for safety
• High power factor ballasts (Min. P. F. 90%) are available in a
variety of voltages to meet local area requirements
• Mogul base lamp socket

3L

990-991.qxp

12/16/2013

7:23 PM

Page 990

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

3L VMV High Wattage Series
200-400W High Pressure Sodium
For Medium and High Mounting Heights
Champ® H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe
and P33 Guard

With GR305 Glass
Refractor *

With GRD4
Reflector/Lens

Pendant Mount
(Rigid or Flexible)

3

/4
1
3
/4
1
3
/4
1

200

VMVS2A200GP
VMVS3A200GP
VMVS2A250GP
VMVS3A250GP
VMVS2A400GP
VMVS3A400GP

VMVS2A200GR305
VMVS3A200GR305
VMVS2A250GR305
VMVS3A250GR305
VMVS2A400GR305
VMVS3A400GR305

VMVS2A200GRD4
VMVS3A200GRD4
VMVS2A250GRD4
VMVS3A250GRD4
VMVS2A400GRD4
VMVS3A400GRD4

3

/4
1
/4
1
3
/4
1

200

3

250

VMVS2C200GP
VMVS3C200GP
VMVS2C250GP
VMVS3C250GP
VMVS2C400GP
VMVS3C400GP

VMVS2C200GR305
VMVS3C200GR305
VMVS2C250GR305
VMVS3C250GR305
VMVS2C400GR305
VMVS3C400GR305

VMVS2C200GRD4
VMVS3C200GRD4
VMVS2C250GRD4
VMVS3C250GRD4
VMVS2C400GRD4
VMVS3C400GRD4

3

/4
1
/4
1
3
/4
1

200

3

250

VMVS2TW200GP
VMVS3TW200GP
VMVS2TW250GP
VMVS3TW250GP
VMVS2TW400GP
VMVS3TW400GP

VMVS2TW200GR305
VMVS3TW200GR305
VMVS2TW250GR305
VMVS3TW250GR305
VMVS2TW400GR305
VMVS3TW400GR305

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

250
400

400

400

3
3

/4
/4
3
/4

200
250
400

VMVS25Q200GP
VMVS25Q250GP
VMVS25Q400GP

VMVS25Q200GR305
VMVS25Q250GR305
VMVS25Q400GR305

VMVS25Q200GRD4
VMVS25Q250GRD4
VMVS25Q400GRD4

Stanchion Mount
25° Angle

11/2
11/2
11/2

200
250
400

VMVSJ200GP
VMVSJ250GP
VMVSJ400GP

VMVSJ200GR305
VMVSJ250GR305
VMVSJ400GR305

VMVSJ200GRD4
VMVSJ250GRD4
VMVSJ400GRD4

Stanchion Mount
Straight

11/2
11/2
11/2

200
250
400

VMVSP200GP
VMVSP250GP
VMVSP400GP

VMVSP200GR305
VMVSP250GR305
VMVSP400GR305

3L

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/ 2° Angle

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVS2A200GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVS2A200GR303

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

EXPORT

600V CWI
/600CWI

230V 50Hz
/230 50

240V 50Hz
/240 50

2. Options - Add the required option suffixes, see page 989, in alpha-numeric order.

990

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

990-991.qxp

12/16/2013

7:23 PM

Page 991

VMV High Wattage Series 250400W Pulse Start Metal Halide
For Medium and High Mounting Heights
Champ® H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

3L

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe
and P33 Guard

With GR305 Glass
Refractor *

Pendant
Mount
(Rigid or
Flexible)

3
/4
1
3
/4
1
3
/4
1

250

VMVM2A250GP
VMVM3A250GP
VMVM2A320GP
VMVM3A320GP
VMVM2A400GP
VMVM3A400GP

S828
S828
S828
S828
S828
S828

VMVM2A250GR305
VMVM3A250GR305
VMVM2A320GR305
VMVM3A320GR305
VMVM2A400GR305
VMVM3A400GR305

S828
S828
S828
S828
S828
S828

VMVM2A250GRD4
VMVM3A250GRD4
VMVM2A320GRD4
VMVM3A320GRD4
VMVM2A400GRD4
VMVM3A400GRD4

S828
S828
S828
S828
S828
S828

3
/4
1
3
/4
1
3
/4
1

250

VMVM2C250GP
VMVM3C250GP
VMVM2C320GP
VMVM3C320GP
VMVM2C400GP
VMVM3C400GP

S828
S828
S828
S828
S828
S828

VMVM2C250GR305
VMVM3C250GR305
VMVM2C320GR305
VMVM3C320GR305
VMVM2C400GR305
VMVM3C400GR305

S828
S828
S828
S828
S828
S828

VMVM2C250GRD4
VMVM3C250GRD4
VMVM2C320GRD4
VMVM3C320GRD4
VMVM2C400GRD4
VMVM3C400GRD4

S828
S828
S828
S828
S828
S828

3
/4
1
3
/4
1
3
/4
1

250

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

320
400**

320
400**

320
400**

VMVM2TW250GP
VMVM3TW250GP
VMVM2TW320GP
VMVM3TW320GP
VMVM2TW400GP
VMVM3TW400GP

S828
S828
S828
S828
S828
S828

With GRD4
Reflector/Lens

VMVM2TW250GR305
VMVM3TW250GR305
VMVM2TW320GR305
VMVM3TW320GR305
VMVM2TW400GR305
VMVM3TW400GR305

S828
S828
S828
S828
S828
S828

3
3

/4
/4
3
/4

250
320
400**

VMVM25Q250GP S828
VMVM25Q320GP S828
VMVM25Q400GP S828

VMVM25Q250GR305 S828
VMVM25Q320GR305 S828
VMVM25Q400GR305 S828

VMVM25Q250GRD4 S828
VMVM25Q320GRD4 S828
VMVM25Q400GRD4 S828

Stanchion
Mount
25° Angle

11/2
11/2
11/2

250
320
400**

VMVMJ250GP S828
VMVMJ320GP S828
VMVMJ400GP S828

VMVMJ250GR305 S828
VMVMJ320GR305 S828
VMVMJ400GR305 S828

VMVMJ250GRD4 S828
VMVMJ320GRD4 S828
VMVMJ400GRD4 S828

Stanchion
Mount
Straight

11/2
11/2
11/2

250
320
400**

VMVMP250GP S828
VMVMP320GP S828
VMVMP400GP S828

VMVMP250GR305 S828
VMVMP320GR305 S828
VMVMP400GR305 S828

3L

Quad-Mount
Pendant,
Adjustable
Thru-Feed,
25° Angle,
121/ 2° Angle

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303-S828
** To be used with ED28 (bulb shaped lamp).

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

Lamp Selection Table:
CEC/CSA (cUL)

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

Fixture

Lamp Type

Bulb

120V
/120

Venture

Phillips

Sylvania

MP 320W/BU/ED28/UVS/PS/EM/950 MS320/U/PS

MS320/PS/BU-HOR

MP 320W/BU/ED28/UVS/PS/740

MS320/C/BU/PS

-

MP 320W/C/BU/ED28/EVS/PS/737

-

-

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

VMVM320GP

320W PS MH

ED28, BT28

2. Options - Add the required option suffixes, see page 989,
in alpha-numeric order.
VMVM400GP

www.crouse-hinds.com

400W PS MH

US: 1-866-764-5454

ED28, BT28

MP 400W/BU/ED28/UVS/PS/EM/950 N/A

CAN: 1-800-265-0502

M400/PS/U/BT28

Copyright© 2013 Eaton’s Crouse-Hinds Business

991

992-993.qxp

12/16/2013

3L

7:23 PM

Page 992

VMV High Wattage Series
250-400W Metal Halide

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
For Medium and High Mounting Heights (Suffix S826TB)
®

Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G303 Globe
With GR305 Glass
With GRD4
Style
Size
Watts
and P33 Guard
Refractor *
Reflector/Lens
Pendant Mount
(Rigid or Flexible)

Ceiling Mount
Thru-Feed

3

/4
1
/4
1

250

3

400

/4
1
3
/4
1

250

/4
1
3
/4
1

250

3

Wall Mount
Thru-Feed

400

3

400

VMVM2A250GP
VMVM3A250GP
N/A
N/A

VMVM2A250GR305
VMVM3A250GR305
VMVM2A400GR305
VMVM3A400GR305

VMVM2A250GRD4
VMVM3A250GRD4
VMVM2A400GRD4
VMVM3A400GRD4

VMVM2C250GP
VMVM3C250GP
N/A
N/A

VMVM2C250GR305
VMVM3C250GR305
VMVM2C400GR305
VMVM3C400GR305

VMVM2C250GRD4
VMVM3C250GRD4
VMVM2C400GRD4
VMVM3C400GRD4

VMVM2TW250GP
VMVM3TW250GP
N/A
N/A

VMVM2TW250GR305
VMVM3TW250GR305
VMVM2TW400GR305
VMVM3TW400GR305

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25°
Angle, 121/2° Angle

3

/4
/4

250
400

VMVM25Q250GP
N/A

VMVM25Q250GR305
VMVM25Q400GR305

VMVM25Q250GRD4
VMVM25Q400GRD4

Stanchion Mount
25° Angle

11/2

250

VMVMJ250GP

VMVMJ250GR305

VMVMJ250GRD4

11/2

400

N/A

VMVMJ400GR305

VMVMJ400GRD4

11/2
11/2

250
400

VMVMP250GP
N/A

VMVMP250GR305
VMVMP400GR305

3L

3

Stanchion Mount
Straight

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

EXPORT

600V CWI
/600CWI

230V 50Hz
/230 50

240V 50Hz
/240 50

2. Options - Add the required option suffixes, see page 989, in alpha-numeric order.

992

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

992-993.qxp

12/16/2013

7:23 PM

Page 993

3L

VMV High Wattage Series –
Ordering by Components

VMV High Wattage Luminaires are available in components.
A complete luminaire consists of:
I.
II.
III.

Champ Cover (Mounting Module)
VMV Ballast Housing – Include voltage and required option(s)
Optical & Guard Components – Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module):
Type
Pendant

Conduit

Cat. #

3

/4"
1"

APM2
APM3

Ceiling

3

/4"
1"

CM2
CM3

Wall

3

/4"
1"

TWM2
TWM3

Stanchion – 25 Degree Angle

11/2"

JM5

Stanchion – Straight

11/2"

PM5

Quad-Mount

3

/4"

QM25

II. Ballast Housings:
Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Metal Halide

Lamp Watts

Cat. #

200
250
400
250
400

VMVS200/MT
VMVS250/MT
VMVS400/MT
VMVM250/MT
VMVM400/MT

III. Globe, Reflectors, Refractors, Guards:
Cat. #

Globe

G303

Globe Guard

P33

Reflector – Dome

RD739

Reflector – Angle

RA739

Refractor – Type 2

GR302

Refractor – Type 3

GR303

Refractor – Type 5

GR305

Refractor Guard

P23

High Bay Reflector/Lens

GRD4

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

3L

Type

Copyright© 2013 Eaton’s Crouse-Hinds Business

993

994-995.qxp

3L

12/16/2013

7:23 PM

Page 994

VMV High Wattage Series

Family Tree

3L

Champ® H.I.D. Luminaires

994

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

994-995.qxp

12/16/2013

7:23 PM

Page 995

VMV High Wattage Series

Temperature Performance Data

3L

Champ® H.I.D. Luminaires

High Pressure Sodium
200

40
55
65

325 C 350 C
325 C 350 C
325 C 350 C

250

40
55
65

400

40
55

T2
T2
T2

T3
T3
T3

T4
T4
–

T3C
–
–

T1/T3C
–
–

T3C
–
–

75
75
85

350 C 350 C 325 C
350 C 350 C 350 C
350 C 350 C
–

T3
T3
T3

T4
T4
–

T3C
–
–

T1/T3C
–
–

T3C
–
–

75
85
–

350 C 350 C
350 C 350 C

T3
T3

T4
T4

T3C
–

T1/T3C
–

T3C
–

85
90

T1
T1

Metal Halide
40
55

350 C 325 C 350 C
350 C 350 C 350 C

T3
T3

T4
T4

T3B
–

350 C/T3B
–

T3B
–

85
90

250

40
55

350 C 325 C 350 C
350 C 350 C 350 C

T3
T3

T4
T4

T3B
–

350 C/T3B
–

T3B
–

85
90

400

40
55

–
–

T4
–

T3B
–

350 C/T3B
–

T3B
–

85

T3
T3

T4
T4

T3B
–

350 C/T3B
–

T3B
–

85
90

–
–

325 C
350 C

T1
T1

3L

200

–

Pulse Start Metal Halide (S828)
250

40
55

350 C 350 C 325 C
350 C 350 C 350 C

320

40

T1

325 C

T2A

T3

–

–

–

–

90

400

40

T1

T1

T1

T3

T4

–

–

–

90

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

995

996-997.qxp

12/16/2013

7:23 PM

Page 996

VMV High Wattage Series

3L

Dimensions & Weights

Champ® H.I.D. Luminaires
Dimensions
In Inches:

Pendant Mount

Ceiling Mount

Wall Mount

25° Angle
Stanchion Mount

Luminaire with
Glass Refractor, Guard

3L

Quad-Mount

Luminaire with Etched Alzak
Reflector/Lens

Straight Stanchion Mount

Luminaire with Globe,
Guard, Reflectors

Net Luminaire Weights (lbs.):
Luminaire
Series
VMVS
VMVM

Lamp
Watts
200
250
400
250
400

Luminaire with:
Globe,
Reflector/
Guard (lbs.) Lens
291/2
291/2
381/2
321/2

30
30
39
33
34

Type
Lbs.
Type
Add for mounting modules:
Quad-Mount
Pendant
11/4
Angle Stanchion
Ceiling
23/4
Straight Stanchion
Wall
41/2
Add for reflectors:
30° Angle
Dome
11/2
High Bay
13/4
Deduct: 11/2 lb. for luminaire without P33 Guard
996

www.crouse-hinds.com

US: 1-866-764-5454

Glass
Refractor (lbs.)
321/2
321/2
411/2
353/4
351/2
Lbs.
31/2
31/2
41/2
11/2

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

996-997.qxp

12/16/2013

7:23 PM

Page 997

3L

Photometric Data

VMV High Wattage Series
Champ® H.I.D. Luminaires

Lamp: 250W/E–18 high pressure sodium (HPS)
Total bare lamp lumens: 27500
Note: All data provided is for high pressure sodium luminaires with 250W/E–18 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Eaton's Crouse-Hinds for additional photometric data on any Champ series luminaire.

Luminaire with Globe and Dome Reflector
Multipliers (for use with
candela curve only).
ConLuminaire Lamp version
Series
Watts Factor
VMVS

200
400

0.80
1.82

Luminaire spacing ratio: 2.0

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall

5

50
30
10

.750
.711
.677

.640
.582
.532

.550
.482
.429

.476
.402
.346

.416
.341
.285

70

50
30
10

.732
.696
.664

.625
.570
.526

.538
.474
.424

.465
.397
.343

.405
.335
.282

50

50
30
10

.695
.666
.641

.594
.549
.509

.513
.458
.414

.443
.384
.336

.388
.326
.279

30

50
30
10

.663
.640
.618

.567
.530
.496

.490
.443
.405

.423
.372
.330

.371
.316
.273

10

50
30
10

.635
.615
.597

.542
.510
.483

.469
.429
.395

.405
.360
.323

.355
.307
.268

0

0

.580

.464

.377

.305

.251

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.369
.295
.243

.327
.255
.208

.290
.222
.173

.263
.196
.150

.229
.163
.121

70

50
30
10

.360
.291
.239

.320
.251
.204

.285
.219
.172

.258
.193
.149

.224
.163
.121

50

50
30
10

.344
.283
.236

.306
.243
.200

.272
.213
.170

.247
.189
.147

.216
.159
.119

30

50
30
10

.330
.275
.233

.292
.238
.196

.262
.207
.167

.238
.183
.145

.207
.154
.116

10

50
30
10

.317
.267
.229

.282
.233
.194

.251
.202
.165

.229
.179
.142

.200
.150
.114

0

0

.212

.178

.149

.128

.101

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

3L

US: 1-866-764-5454

4

80

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

Room Cavity Ratio
1
2
3

997

998-999.qxp

12/16/2013

7:24 PM

Page 998

Luminaires with Induction
Lighting System

3L

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC
Restricted Breathing Suffix
S826 for CI. I, Div. 2 & Zone 2

VMVIG and DMVIG Series

Enclosure Type 4X, IP66
Wet Locations
Marine Locations
UL and cUL Listed

Get uninterrupted light for up to 11 years,
without changing a lamp.
Eaton's Crouse-Hinds Champ Luminaire with Induction Light Source
delivers up to 100,000 hours of white light in a hazardous location,
corrosion-resistant watertight package. That’s 5 to 8 times the
typical life of conventional fluorescent or HID lamps. And, with no
maintenance required for up to 11 years, you’ll reduce your
maintenance and lamp replacement costs.
Compelling reasons to choose the new Champ Induction
Luminaire as the light source for industrial and hazardous
locations include:
• Crisp, white light (80+ color rendering index) provides increased
safety by clearly illuminating signs, instrument panels, equipment
and more with vibrant natural colors.
• Up to 100,000 hours of lamp life minimizes routine maintenance
costs. If you operate this luminaire for 24 hours, 7 days a week,
you will not need to change the lamp for up to 11 years!
• Instant illumination — no waiting for lamp warm-up time. Increases
productivity and safety.
• Delivers the best possible luminaire temperature rating — T6
(85°C) when used with the Champ restricted breathing option.
Ideal for hazardous areas where a low ignition temperature is
required.
• Starts in low temperatures — as low as –40°C.

165W Champ Induction provides as much light as a 175W Metal
Halide but lasts 7 times longer!

Additional Features and Benefits:
The Champ Induction Luminaire is suitable for Class I, Division 2 and
Zone 2 areas with the assurance of Eaton's Crouse-Hinds quality
and reliability. They are ideal for use in hard-to-reach applications
and where process requirements demand continuous luminaire
operation.

3L

Features:
• High lumens per watts (72 lpw for the 165W Champ) will save
energy
• Retains strong light output (retains more than 70% output)
throughout the life of the lamp
• Will not add electrical noise to the circuits — Total Harmonic
Distortion is less than 10%
• Excellent power factor of .96 increases useable watts to an
excellent level and reduces energy consumption
• Internal electronics are enclosed to ensure that there is no
interference with external instrumentation

998

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

998-999.qxp

12/16/2013

7:24 PM

Page 999

Luminaires with Induction
Lighting System
VMVIG and DMVIG Series
with Lamps Included

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC
Restricted Breathing Suffix
S826 for CI. I, Div. 2 & Zone 2

Enclosure Type 4X, IP66
Wet Locations
Marine Locations
UL and cUL Listed

Applications:

Options:

Champ Induction Luminaires are ideal:
• Where an extra long life lamp source (up to 100,000 hours)
is required.
• In areas that require lamps to reach full illumination immediately.
• Where cool temperature ratings on the luminaire globe are needed
to ensure safe operation in hazardous areas.
• In hard-to-reach applications where relamping is costly.
• Where luminaire maintenance is difficult due to continuous process
operation requirements that restrict or prohibit shut down except in
emergency situations.
• To provide a cost-effective lighting system (low installed/life cost)
by minimizing or even eliminating routine luminaire maintenance.
• In cold environment applications.

Description
Restricted Breathing Construction
Class I, Division 2 & Zone 2 suitability
Cooler operating temperatures (T-Codes)
Corrected color temperature lamp - 4000K

Certifications and Compliances:
• NEC & CEC:
Class I, Division 2 and Zone 2
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
• Restricted Breathing Suffix S826 for Class I, Division 2 and Zone 2
• Marine Locations, Wet Locations, Enclosure Type 3, 3R, 4, 4X; IP66
• UL and cUL Listed / ETL
• UL Standards: 844, 60079-15, 1598, 1598A
• CSA Standards: C22.2 No.137, E79 Series

Compliances and approvals for the lamp system
•
•
•
•
•

RFI < 30 MHz
RFI > 30 MHz
Harmonics
Immunity
Safety

• Performance
• Vibration & bump tests

Suffix
S826
S887

Accessories:
Mounting Modules

Cat. #

/4 NPT Pendant
1 NPT Pendant
3
/4 NPT Flexible Pendant
3
/4 NPT Ceiling Mount
1 NPT Ceiling Mount
3
/4 NPT Wall Mount
1 NPT Wall Mount
3
/4 NPT Quad Mount
11/2 NPT Stanchion Mount — 25 Degree Angle
11/2 NPT Stanchion Mount — Straight

APM2
APM3
HPM2
CM2
CM3
TWM2
TWM3
QM25
JM5
PM5

3

Wattage

Dome Reflector
Cat. #

Angle Reflector
Cat. #

55W
85W
165W

RD70
RD739
RD739

RA70
RA739
RA739

Dimensions:
See Section 3L for dimensional information on
VMV and DMV Series.

Amperage:
Power consumption for specific voltages
55W Luminaires
a. 120VAC x .460mA = 55.70 watts
b. 230VAC x .260mA = 59.80 watts
85W Luminaires
c. 120VAC x .710mA = 85.20 watts
d. 230VAC x .400mA = 92.00 watts

3L

• Quality standards
• Environmental standard

EN 55015
EN 55022
EN 61000-3-2
EN 61547
EN 61347-2-3 & UL935
EN 60928
EN 60929
IEC 68-2-6-Fc
IEC 68-2-29-Eb
ISO 9001
ISO 14001

3L

165W Luminaires
e. 120VAC x 1.35 = 162.00 watts
f. 230VAC x .700mA = 161.00 watts

Standard Materials:
• Ballast housings and mountings – copper-free aluminum
(less than 0.4 of 1%)
• Exterior hardware – stainless steel
• Reflectors (dome and angle) – Krydon fiberglass-reinforced
polyester material
• Globes – heat and impact-resistant internally fluted glass
• Guards – copper-free aluminum (55W), stainless steel (85W)

Standard Finishes:
• Copper-free aluminum – epoxy powder coat
• Krydon® material – high reflectance white
• Stainless steel – natural

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

999

1000-1001.qxp

12/16/2013

3L

7:24 PM

Page 1000

Luminaires with Induction
Lighting System

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC
Restricted Breathing Suffix
S826 for CI. I, Div. 2 & Zone 2

VMVIG and DMVIG Series

Enclosure Type 4X, IP66
Wet Locations
Marine Locations
UL and cUL Listed

Lamp Data:

VMV
DMV
DMV

55
85
165

3500
6000
12000

Initial

Mean

Color
Rendering
Index*

65
70
72

51
57
58

80
80
80

Efficacy (LM/W)

Lumen (LM)
Initial
Mean

System
Power (W)

2800
4800
9600

Lumen
Maintenance
After 60,000 Hrs (%)
75
75
70

*Lamp sources with 80+ CRI provide excellent color rendering. CRI scale is 0–100 with 100 considered as ideal.

Temperature Performance Data:
Cat. #

Watts

Ambient
Temp. °C

Supply Wire
Temp. °C

Class I, Div. 2
Temp. Rating

Class II, Div. 1,
Class III
Temp. Rating

VMVIG055
55
40
60
T2C
–
VMVIG055
55
55
75
T2C
–
DMVIG085
85
40
60
T3
T5
DMVIG085
85
55
75
T2D
T4A
DMVIG165
165
40
75
T3
–
Champ Induction DMV 85 watt is now Class II, Div. 1 – suitable for dust environments.

Simultaneous
Presence
Class I, Div. 2
–
–
T2D
–
–

Restricted Breathing
(Suffix S826)
Aex nR IIC, Ex nR IIC
Class I, Div. 2/Zone 2
T6
T5
T6
T5
T5

Ordering Information:
To complete Catalog Number, add Voltage and Option suffix(es).

Hub Size
(Inches)

55W Induction
Catalog Number
(With G24 Globe
& P21 Guard)

85W Induction
Catalog Number
(With G303 Globe
& P33 Guard)

165W Induction
Catalog Number
(With G303 Globe
& P33 Guard)

Pendant

/4
1

VMVIG2A055GP
VMVIG3A055GP

DMVIG2A085GP
DMVIG3A085GP

DMVIG2A165GP
DMVIG3A165GP

Flexible Pendant

3

/4

VMVIG2HA055GP

DMVIG2HA085GP

DMVIG2HA165GP

/4
1

VMVIG2C055GP
VMVIG3C055GP

DMVIG2C085GP
DMVIG3C085GP

DMVIG2C165GP
DMVIG3C165GP

Wall Mount

/4
1

VMVIG2TW055GP
VMVIG3TW055GP

DMVIG2TW085GP
DMVIG3TW085GP

DMVIG2TW165GP
DMVIG3TW165GP

Quad Mount

3

DMVIG25Q165GP

Mounting Style

3

3

Ceiling Mount

3L

3

/4

VMVIG25Q055GP

DMVIG25Q085GP

Stanchion Mount 25° Angle

11/2

VMVIGJ055GP

DMVIGJ085GP

DMVIGJ165GP

Stanchion Mount Straight

11/2

VMVIGP055GP

DMVIGP085GP

DMVIGP165GP

Luminaire with Globe and Guard
less Mounting Module

—

VMVIG055GP

DMVIG085GP

DMVIG165GP

Add the voltage suffix to the above catalog number. Ex. - DMVIG2A085GP/120
Standard Voltage
Suffix
Range
120V, 50 / 60 Hz
/120
Operative range of 108–132 VAC
200V–277V, 50 / 60 Hz
/200 277
Operates on 208, 220, 230, 240, 277 VAC

1000

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1000-1001.qxp

12/16/2013

7:24 PM

Page 1001

Luminaires with Induction
Lighting System

3L

Photometric Data

VMVIG and DMVIG Series
55 Watt Induction
Luminaire With Globe And Guard
VMVIG055GP LAMP: 55W Induction

85 Watt Induction
Luminaire With Globe And Guard
DMVIG085GP LAMP: 85W Induction

3L

Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our
Luxicon Lighting Layout Software are available to download.
www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1001

1002-1003.qxp

3L

12/16/2013

7:24 PM

Page 1002

Luminaires with Induction
Lighting System

Photometric Data

VMVIG and DMVIG Series
165 Watt Induction
Luminaire With Globe
DMVIG165G Lamp: 165W Induction

165 Watt Induction
Luminaire With Globe And Guard

3L

DMVIG165GP Lamp: 165W Induction

Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our
Luxicon Lighting Layout Software are available to download.
1002

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1002-1003.qxp

12/16/2013

7:24 PM

Page 1003

Luminaires with Induction
Lighting System

Photometric Data

3L

VMVIG and DMVIG Series
165 Watt Induction
Luminaire With Globe And RD739 Dome Reflector
DMVIG165G Lamp: 165W Iinduction

165 Watt Induction
Luminaire With Globe And RA739 (30° Angle) Reflector
DMVIG165G Lamp: 165W Induction

3L

Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our
Luxicon Lighting Layout Software are available to download.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1003

1004-1005.qxp

3L

12/16/2013

7:24 PM

Page 1004

Luminaires with Induction
Lighting System

Family Tree

3L

VMVIG and DMVIG Series

1004

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1004-1005.qxp

12/16/2013

7:24 PM

Page 1005

N2MV Series 50-175W
Non-metallic
Champ® H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Marine & Wet Locations
3, 3R, 4, 4X; IP56

3L

Options:
The following special options are available
from the factory by adding suffix to
luminaire Cat. No.:

Certifications and
Compliances:

Features:

Standard Materials:

• Housing and mounting modules made of
polyphenylene sulfide (PPS) for strength
and maximum resistance to corrosion.
• Pendant mounting module equipped
with integral hub set screws for vibration
resistance.
• Hubs are provided with an integral
bushing to help prevent damage to field
wiring during installation and ground
connection for positive bonding.
• Guard, hub inserts, stanchion elbow and
hardware made of stainless steel for
maximum resistance to corrosion.
• Grounding wire for safety.
• Stainless steel open bottom guard
permits direct access to the globe for
easy relamping.
• Hinged assembly allows the luminaire to
hang free during installation to permit the
use of both hands when wiring.
• One external captive screw for ease of
installation.
• Handle – hinge assembly doubles as a
handle for ease of installation, especially
when carrying up a ladder.

• Housing, mounting modules,
component pallets – polyphenylene
sulfide (PPS)
• Guard, hub inserts, stanchion elbow,
hardware – stainless steel
• Globe – heat tempered
• Gaskets – silicone rubber

• NEC and CEC:
Class I, Division 2, Groups A, B, C, D
100W Maximum – Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards
C22.2 No. 137

Electrical Ratings:
• 120, multi-tap/MT (120, 208, 240 and
277), Dual-Tap/DT (120, 277 volts),
Tri-Tap/TT (120, 277, 347 volts) 480 volt,
600 volt, 220 / 240 volt-50 Hz
• 50–150W HPS; 70–175W MH and Pulse
Start MH

www.crouse-hinds.com

Description
Suffix
• Wall Mount Arm. For converting
ceiling mount luminaire to a
wall mount. ......................... N2MV-WM1
• Ballast-Gard™ starter cut-out
switch. Prevents starter pulsing
when lamp is cycling or
inoperative; prolongs ballast
and ignitor life. Available for use
with 50–150 watt – HPS .............
BG
• Factory Assembled. For a
factory assembled luminaire
with lamp installed......................
FA
• Instant Restrike. Enables a hot
HPS lamp to immediately
restrike after a momentary loss
of arc due to voltage fluctuation
or power outage. It has no
effect on the warm-up period of
cold lamps.
50–150W LX HPS only..............
IR
50–100W LX HPS only..............
TIR
• Quartz Auxiliary Lighting.
Comes to full brightness
immediately and remains lit until
the HID lamp attains 60–70% of
full illumination. For nonhazardous locations only. (Note:
QTZ lamp not included; use
100W single ended lamp –
Q100DC, Q100CL/DC, or
100Q/CL/DC) Consult factory
for top-hat limitations .................
QTZ
• Fused. To protect ballast and
capacitor against abnormal line
conditions ................................... S658
(Not available with /MT ballast )
(Not for use in Canada) (Not
suitable for marine applications)
• Furnished with Lamps ................ S714
• Teflon® Coated Globe. For
additional protection against
breakage. For use with
50–100W HPS, 70–175W MH
and pulse start MH ..................... S808

Accessories:
• See pages 1022–1023 for complete
listing.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1005

3L

Applications:
N2MV series Champ luminaires are used:
• In areas in which ignitable
concentrations of flammable gases or
vapors will be present due to abnormal,
unusual or accidental conditions.
• In installations where moisture, dirt,
vibration, corrosion or rough usage are
concerns.
• Wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are
found.
• Ideal for marine use; resists the harmful
effects of salt water.
• Withstands the harshest of corrosive
environments.
• To provide low wattage spot and
floodlighting.
• For general area lighting.
• In areas where the ambient temperature
will get as low as 40°C (–40°F).
• In manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities, wastewater
and sewage treatment facilities,
offshore, dockside and harbor
installations as well as other heavy
industrial applications.

1006-1007.qxp

12/16/2013

3L

7:24 PM

Page 1006

N2MV Series 50–150W
High Pressure Sodium

Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Non-metallic
Champ® H.I.D. Luminaires

Marine & Wet Locations
3, 3R, 4, 4X; IP56

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page.

Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion
Mount
25° Angle

Hub
Size

Lamp
Watts

/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
11/2
11/2
11/2
11/2

50

3

70
100
150
50
70
100
150
50
70
100
150

BASIC CATALOG NUMBER
With G303 Globe and
With GR305
P33 Guard
Glass Refractor *
N2MVS2A050GP
N2MVS3A050GP
N2MVS2A070GP
N2MVS3A070GP
N2MVS2A100GP
N2MVS3A100GP
N2MVS2A150GP
N2MVS3A150GP
N2MVS2C050GP
N2MVS3C050GP
N2MVS2C070GP
N2MVS3C070GP
N2MVS2C100GP
N2MVS3C100GP
N2MVS2C150GP
N2MVS3C150GP
N2MVSJ050GP
N2MVSJ070GP
N2MVSJ100GP
N2MVSJ150GP

N2MVS2A050GR305
N2MVS3A050GR305
N2MVS2A070GR305
N2MVS3A070GR305
N2MVS2A100GR305
N2MVS3A100GR305
N2MVS2A150GR305
N2MVS3A150GR305
N2MVS2C050GR305
N2MVS3C050GR305
N2MVS2C070GR305
N2MVS3C070GR305
N2MVS2C100GR305
N2MVS3C100GR305
N2MVS2C150GR305
N2MVS3C150GR305
N2MVSJ050GR305
N2MVSJ070GR305
N2MVSJ100GR305
N2MVSJ150GR305

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVS2A050GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVS2A050GR303

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

120V
/120

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps - add suffix CE. 50W HPS luminaire is dual tap only.

3L

3. Options - Add the required option suffixes, see page 1005, in alpha-numeric order.

1006

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1006-1007.qxp

12/16/2013

7:24 PM

Page 1007

N2MV Series 150–175W
Pulse Start Metal Halide
Non-metallic
Champ® H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Marine & Wet Locations
3, 3R, 4, 4X; IP56

3L

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see N2MV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Hub
Size

Lamp
Watts

With G303 Globe and
P33 Guard *

With GR305–S828 Glass
Refractor

3
/4
1
3
/4
1

150

N2MVM2A150GP
N2MVM3A150GP
N2MVM2A175GP
N2MVM3A175GP

S828
S828
S828
S828

N2MVM2A150GR305
N2MVM3A150GR305
N2MVM2A175GR305
N2MVM3A175GR305

S828
S828
S828
S828

3
/4
1
3
/4
1

150

N2MVM2C150GP
N2MVM3C150GP
N2MVM2C175GP
N2MVM3C175GP

S828
S828
S828
S828

N2MVM2C150GR305
N2MVM3C150GR305
N2MVM2C175GR305
N2MVM3C175GR305

S828
S828
S828
S828

Stanchion Mount 11/2
25° Angle
11/2

175

175

150
175

N2MVMJ150GP S828
N2MVMJ175GP S828

N2MVMJ150GR305 S828
N2MVMJ175GR305 S828

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A150GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A150GR303-S828

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)

120V
/120

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

120V
/120

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

2. Options - Add the required option suffixes, see page 1005, in alpha-numeric order.

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1007

1008-1009.qxp

12/23/2013

3L

3:12 PM

Page 1008

N2MV Series 70–175W
Metal Halide

Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Non-metallic
Champ® H.I.D. Luminaires

Marine & Wet Locations
3, 3R, 4, 4X; IP56

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion
Mount
25° Angle

Hub
Size

Lamp
Watts

With G303 Globe and
P33 Guard

With GR305 Glass
Refractor *

3
/4
1
3
/4
1
3
/4
1

70

N2MVM2A070GP
N2MVM3A070GP
N2MVM2A100GP
N2MVM3A100GP
N2MVM2A175GP
N2MVM3A175GP

N2MVM2A070GR305
N2MVM3A070GR305
N2MVM2A100GR305
N2MVM3A100GR305
N2MVM2A175GR305
N2MVM3A175GR305

3
/4
1
3
/4
1
3
/4
1

70

N2MVM2C070GP
N2MVM3C070GP
N2MVM2C100GP
N2MVM3C100GP
N2MVM2C175GP
N2MVM3C175GP

N2MVM2C070GR305
N2MVM3C070GR305
N2MVM2C100GR305
N2MVM3C100GR305
N2MVM2C175GR305
N2MVM3C175GR305

11/2
11/2
11/2

70
100
175

N2MVMJ070GP
N2MVMJ100GP
N2MVMJ175GP

N2MVMJ070GR305
N2MVMJ100GR305
N2MVMJ175GR305

100
175

100
175

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A070GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A070GR303

1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts

3L

Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

EXPORT

600V CWI
/600CWI

230V 50Hz
/230 50

240V 50Hz
/240 50

2. 70W ballast not available in 480V.
3. Options - Add the required option suffixes, see page 1005, in alpha-numeric order.

1008

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1008-1009.qxp

12/23/2013

3:12 PM

Page 1009

N2MV Series –
Ordering by Components

3L

N2MV luminaires are available in components.
A complete luminaire consists of:
I.
N2MV Cover (Mounting Module)
II.
N2MV Ballast Housing – Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector

I. N2MV Cover (Mounting Module):
Type
Pendant

Conduit

Cat. #

3

/4"
1"

N2APM2
N2APM3

Ceiling

3

/4"
1"

N2CM2
N2CM3

Wall (Use wall bracket accessory with
Ceiling Cover)
Stanchion – 25 Degree Angle

3

/4"
1"

N2MV WM1 and N2CM2
N2MV WM1 and N2CM3

11/2"

N2JM5

II. Ballast Housings:
Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp
Lamp Type
Watts
Cat. #
High Pressure Sodium
50
N2MVS050/MT
70
N2MVS070/MT
100
N2MVS100/MT
150
N2MVS150/MT LX
Metal Halide

70
100
175

N2MVM070/MT
N2MVM100/MT
N2MVM175/MT

III. Globe, Refractors, Guards and Reflectors:
Cat. #

Globe
Globe Teflon Coated
Globe Guard
Reflector – Dome
Reflector – Angle
Refractor – Type 2
Refractor – Type 3
Refractor – Type 5
Refractor Guard
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

G303

3L

Type

G303S808
P33
RD739
RA739
GR302
GR303
GR305
P23
PGR302
PGR303
PGR305

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1009

1010-1011.qxp

3L

12/16/2013

7:25 PM

Page 1010

N2MV Series

Family Tree

Champ® H.I.D Luminaires

3L

*Plastic refractors are non-hazardous areas only (50-100W Max.)

1010

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1010-1011.qxp

12/16/2013

7:25 PM

Page 1011

N2MV Series

3L

Temperature Performance Data

Champ® H.I.D Luminaires

High Pressure Sodium
40
55
50
65

T3A
T3A
–

T4A
–
–

75
85
–
75
85
–

40
55
65

T3A
T3A
–

T4A
–
–

100

40
55
65

T2D
T2C
–

T4A
–
–

T2C/T4A
–
–

85
100
–

150

40
55
65

T2C
–
–

–
–
–

–
–
–

85
–
–

70

40
55
65

T3C
T3B
–

T4
–
–

T2B/T4
–
–

75
85
–

100

40
55
65

T2B
T2B
–

T4
–
–

T2B/T4
–
–

85
–
–

150
(S828)

40
55
65

T2
–
–

–
–
–

–
–
–

–
–
–

175
(Includes
S828)

40
55
65

T2
–
–

–
–
–

–
–
–

–
–
–

3L

70

T2C/T4A
–
–
T2C/T4A
–
–

Metal Halide

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1011

1012-1013.qxp

12/16/2013

3L

7:25 PM

Page 1012

N2MV Series

Dimensions and Weights

Champ® H.I.D. Luminaires
Dimensions
In Inches:

Ceiling Mount

3L

Ceiling Mount – Top View

Pendant Mount

25° Angle Stanchion Mount

Net Luminaire Weights (lbs.):
Luminaire
Series

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

N2VMS

50
100

23
241/16

70
150

231/16
261/8

N2MVM

70
175

21
221/4

100
250

211/16
24

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Ceiling
23/4
Quad-Mount
31/2
Straight Stanchion
41/2

www.crouse-hinds.com

US: 1-866-764-5454

Lbs.

Flexible Pendant
Wall
Angle Stanchion

11/2
41/2
31/2

Add for reflectors:
30° Angle
Dome
11/ 4
Deduct: 1 lb. for luminaire without P33 Guard.
1
Add: 5 / 2 lbs. for luminaire with GR305 refractor.

Wall Arm Mount

1012

Type

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

13/4

1012-1013.qxp

12/16/2013

7:25 PM

Page 1013

N2MV Series

3L

Photometric Data

Champ® H.I.D Luminaires
Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
All data provided is for high pressure sodium luminaires with 150W/E-23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult
Eaton's Crouse-Hinds for additional photometric data on any Champ series luminiares.

Luminaire with Globe and Dome Reflector
Multipliers (for use with
candela curve only).

Luminaire
Series

Lamp
Watts

Conversion
Factor

N2MVS

50
70
100

0.25
0.40
0.59

Isofootcandle Chart: Luminaire with
Globe and Dome Reflector

Luminaire spacing ratio: 1.90

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall

4

5

80

50
30
10

.759
.719
.683

.643
.582
.530

.551
.480
.424

.476
.400
.342

.418
.340
.283

70

50
30
10

.740
.703
.669

.627
.570
.523

.538
.471
.418

.465
.394
.338

.406
.334
.280

50

50
30
10

.703
.672
.645

.595
.548
.506

.512
.455
.408

.442
.381
.332

.388
.324
.276

30

50
30
10

.669
.646
.622

.567
.528
.492

.488
.439
.399

.422
.368
.325

.370
.314
.270

10

50
30
10

.640
.619
.600

.541
.508
.479

.466
.424
.389

.403
.356
.318

.354
.305
.265

0

0

.582

.459

.370

.299

.247

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.371
.296
.243

.330
.257
.208

.294
.224
.174

.267
.198
.151

.231
.164
.121

70

50
30
10

.362
.291
.238

.323
.252
.204

.288
.221
.173

.262
.195
.151

.226
.164
.121

50

50
30
10

.345
.283
.235

.309
.244
.201

.275
.215
.170

.250
.190
.148

.218
.159
.119

30

50
30
10

.331
.275
.231

.294
.239
.196

.265
.208
.168

.240
.184
.146

.209
.154
.116

10

50
30
10

.317
.266
.227

.284
.233
.193

.253
.203
.165

.231
.180
.143

.201
.150
.114

0

0

.210

.177

.149

.128

.100

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

US: 1-866-764-5454

Isofootcandle Chart: Luminaire with
Globe and 30° Angle Reflector

3L

Room Cavity Ratio
1
2
3

Isofootcandle charts show illumination in footcandles on work plane
10 feet below light center. Multiply by factor shown to convert to
other mounting heights.
Height (Ft.)

Factor

Height (Ft.)

Factor

8
12
14

1.56
.694
.510

16
20

.391
.250

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1013

1014-1015.qxp

12/16/2013

3L

7:25 PM

Page 1014

NVMV Series 70-400W Ex-Protected
Luminaire for IEC and ATEX Applications
Champ® H.I.D. Luminaires

The Champ® NVMV design is optimized for
Zone 2 gas applications (with standard
restricted breathing Ex nR protection), as
well as Zone 21 dust applications.

Applications:
NVMV Ex-Protected Luminaires are suitable
for applications in Zone 2/Zone 21/Zone
22:
• In manufacturing plants, refineries,
chemical, petrochemical, and other
industrial process facilities, waste or
sewage treatment facilities, dockside and
other heavy industrial applications
• In areas where combustible dusts or
fibers may be present
• In areas where ignitable concentrations
of flammable gases or vapors will be
present
• In installations where moisture, dirt, dust,
vibration, corrosion, and rough usage are
problematic

3L

Features:
• One product offering for global
applications. The Champ family has the
required IEC and ATEX certifications to
provide solutions for specification
requirements around the world.
• Restricted breathing (Ex nR)
protection is standard. This provides
better T-ratings, as gases will not enter
the lamp chamber and control gear
housing.
• Provides an integrated ballast with
thermal cut-off functionality incorporated
into the control gear. In the event of
abnormal temperatures or when the lamp
approaches end of life, the cut-off
functionality protects the ballast from
overheating or burning out.
• Identical mounting cover for IEC and
NEC applications - regardless of
wattage, options, and accessories.
Reduce inventory costs and provide
greater flexibility for engineering
designers, customers, and distributors.
• HPS lamps restrike in 10-30 seconds
with the instant restrike option (IR) should
lamp extinguish due to system voltage
drop or momentary loss. Optional builtin cut-off feature will shut off the instant
restrike to avoid continuous high energy
pulsing when lamp is inoperative or
nearing end of life.
• Available with the Champ Quick-Clip.
Quick-Clip secures the housing to the
cover, providing faster, easier, and safer
luminaire installation.

1014

www.crouse-hinds.com

US: 1-866-764-5454

Ex nR II T...Gc
Ex t IIIC T...°C Db IP66
LCIE 09 ATEX 1002
LCIE 09 ATEX 3008

Certifications and
Compliances:
Application in Zone 2 area acc. IEC
60079-15
• Marking to 94/9/EC: Ex II 3 G Ex nR II
T*...Gc
• EC - Type Examination: LCIE 09 ATEX
1002
Application in Zone 21 and 22 areas acc.
IEC 61241-1
• Marking to 94/9/EC: Ex II 2 D Ex t IIIC
T...ºC(*) Db IP66
• EC - Type Examination: LCIE 09 ATEX
3008
General per both application
Zone 2 and 21
• Temperature ambient of use: -45ºC to
+55ºC
• Electromagnetic compatibility: EN
61000-6-4
• Degree of protection: acc. EN 60529
IP66

NVMV 70W - 250W (Small Housing)

Standard Materials and
Finishes:
• Ballast housing and mountings –
copper-free aluminum
• Exterior hardware – stainless steel
(type 304)
• Reflectors (dome and angle) – Krydon®
fiberglass-reinforced polyester
• Globes – heat and impact-resistant
glass
• Guards – copper-free aluminum and
stainless steel (large housing - stainless
steel only)

NVMV 250W - 400W (Large Housing)

Technical
Specifications:
• Entry
• Termination
• Installation
• Lamp Holder
• Lamp Type
• Lamp Power
• Control Gear
•
•
•
•

Re-lamping
Burning Position
Ingress Protection
Electrical Supply

CAN: 1-800-265-0502

Up to 4 x M20, M25, M32, 1/ 2" NPT and 3/ 4" NPT and 1" NPT
cable entries (11/ 2" NPT for stanchion only)
3 Core 6mm2 max. (standard); 6 x 6mm2 for looping
(available upon request)
Ceiling Mount, Wall Mount, Stanchion Mount, Pendant Mount
E27 or E40
HSE/HST (high pressure sodium lamp) and HIE
(metal halide lamp)
70W, 100W, 150W, 250W, and 400W
Integrated ballast, thermal cut-off functionality incorporated
into control gear
Access via restricted breathing lamp chamber
Base up; up to 25° off vertical
IP66 to EN 60529
220, 230, 240V 50Hz and 220, 230V 60Hz

Copyright© 2013 Eaton’s Crouse-Hinds Business

1014-1015.qxp

12/16/2013

7:25 PM

Page 1015

NVMV Series 70-400W Ex-Protected
Luminaire for IEC and ATEX Applications

3L

Ex nR II T...Gc
Ex t IIIC T...°C Db IP66
LCIE 09 ATEX 1002
LCIE 09 ATEX 3008

Champ® H.I.D. Luminaires
Ordering Information:

Example of Completed Part Number - Small Body: NVMVS1MC075POO
NVMV
Series

S
Lamp

NVMV
S = HSE/HST
Luminaire (HPS)
IEC Gear
M = HIE (MH)

1M
Entry

C
Mounting*

07
5
Wattage Voltage

1M = M20
2M = M25
3M = M32
1N = 1/2" NPT
2N = 3/4" NPT
3N = 1" NPT
5N = 1 1/2" NPT
(For Stanchion)

C = Ceiling
W = Wall
J = Stanchion

07 =
70W
10 =
100W
15 =
150W
25 =
250W

3
5
6
4
7

=
=
=
=
=

220V
230V
240V
220V
230V

/
/
/
/
/

50
50
50
60
60

Hz
Hz
Hz
Hz
Hz

P
Guard

O
Body

O

O = Without
Guard G34
Globe
P = G251
Globe with
P22 Alum.
Guard
S = G251
Globe with
P22 SS304
Guard

O = Small Body

O = Standard

P
Guard

L
Body

O

Example of Completed Part Number - Large Body: NVMVS1MC255PLO
NVMV
Series

S
Lamp

NVMV
S = HSE/HST
Luminaire (HPS)
IEC Gear M = HIE (MH)

C
Mounting*

25
5
Wattage Voltage

1M = M20
2M = M25
3M = M32
1N = 1/2" NPT
2N = 3/4" NPT
3N = 1" NPT
5N = 1 1/2" NPT
(For Stanchion)

C = Ceiling
W = Wall
J = Stanchion

25 =
250W
40 =
400W

3
5
6
4
7

=
=
=
=
=

220V
230V
240V
220V
230V

/
/
/
/
/

50
50
50
60
60

Hz
Hz
Hz
Hz
Hz

O = Without L = Large Body
Guard G303
Globe
P = G303
Globe with
P33 SS
Guard

O = Standard

3L

1M
Entry

Options and Accessories:
Description

Suffix

Instant restrike (100W HPS and 150W HPS) (alternative solution to dual arc lamps) /IR
Dome reflector - small housing
/RD70
30° angle reflector - small housing
/RA70
Dome reflector - large housing
/RD739
30° angle reflector - large housing
/RA739
Champ® Quick-Clip
/S890

*For pendant mounting, order ceiling mount with pendant bracket accessory - please consult factory.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1015

1016-1017.qxp

12/16/2013

3L

7:26 PM

Page 1016

NVMV Series

Temperature Performance Data

Champ® H.I.D. Luminaires
Temperature Performance:
Refer to temperature performance data tables (below) to select luminaire that is suitable for your area specifications. These numbers are the
maximum surface temperature of the luminaire.
Note: T3 - maximum surface temperature 200°C
T4 - maximum surface temperature 135°C
For example: atmospheres that contain gasoline and have an ignition temperature of 536°C, any fixture with the T-rating in this table can be
used.
Atmospheres that contain diethyl ether and have an ignition temperature of 160°C require a luminaire with T4 ratings.

NVMV 70W - 250W (Small Housing)
GAS (Class I, Zone 2)
Ex nR II T...Gc
Catalog Number
Example†

Watts

NVMVS1MC075*00

70W

NVMVS1MC105*00

100W

Lamp
Type

Rated Lamp With
Ambient Holder G34
°C
Globe
Only

HSE/HST
(HPS)
NVMVS1MC155*00

150W

NVMVS1MC255*00

250W

NVMVM1MC075*00

70W

NVMVM1MC105*00

100W

NVMVM1MC155*00

150W

NVMVM1MC255*00

250W

3L

HIE (MH)

40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55

T4
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T4
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3

E27
E40
E40
E40

E27
E27
E27
E40

With
G251
Globe
Only
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T3
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T2
T2

DUST (Class II, Zone 21)
Ex t IIIC T...Db

With
With
With
G34
G251
G34
Globe
Globe Globe
and
and
Only
Reflector Reflector
T4
T4
99°C
T4
T4
109°C
T4
T4
114°C
T4
T4
99°C
T4
T3
109°C
T4
T3
114°C
T3
T3
122°C
T3
T3
132°C
T3
T3
137°C
T3
T2
168°C
T2
T2
178°C
T2
T2
183°C
T4
T4
99°C
T4
T4
109°C
T4
T4
114°C
T4
T4
99°C
T4
T3
109°C
T4
T3
114°C
T3
T3
122°C
T3
T3
132°C
T3
T3
137°C
T3
T2
168°C
T2
T2
178°C
T2
T2
183°C

With
G251
Globe
Only
109°C
119°C
124°C
117°C
127°C
132°C
140°C
150°C
155°C
174°C
184°C
189°C
109°C
119°C
124°C
117°C
127°C
132°C
140°C
150°C
155°C
194°C
204°C
209°C

With
With
G34
G251
Globe
Globe
and
and
Reflector Reflector
104°C
109°C
114°C
119°C
119°C
124°C
104°C
128°C
114°C
138°C
119°C
143°C
140°C
140°C
150°C
150°C
155°C
155°C
189°C
218°C
199°C
228°C
204°C
233°C
104°C
109°C
114°C
119°C
119°C
124°C
104°C
128°C
114°C
138°C
119°C
143°C
140°C
140°C
150°C
150°C
155°C
155°C
189°C
218°C
199°C
228°C
204°C
233°C

†Cat. No. - shown with M20 Ceiling Mount, /230V, 50 Hz.

NVMV 250W - 400W (Large Housing)

Catalog Number
Example

Watts

NVMVS1MC255*L0

250W

NVMVS1MC405*L0

400W

NVMVM1MC255*L0

250W

NVMVM1MC405*L0

400W

1016

www.crouse-hinds.com

Lamp
Type

Rated
Ambient
°C

HSE/HST
(HPS)

40
50
55
40
50
55

HIE (MH)

40
50
55
40
50
55

US: 1-866-764-5454

Lamp
Holder

E40
E40

E40
E40

CAN: 1-800-265-0502

GAS (Class I, Zone 2)
Ex nR II T...Gc
With G303 With G303
Globe Only Globe and
Reflector

DUST (Class II, Zone 21)
Ex t IIIC T...Db
With G303 With G303
Globe Only Globe and
Reflector

T3
T3
T3
T3
T3
T3

T3
T3
T3
T3
T3
T3

137°C
147°C
152°C
159°C
169°C
174°C

137°C
147°C
152°C
175°C
185°C
190°C

T3
T3
T3
T3
T3
T3

T3
T3
T3
T3
T2
T2

137°C
147°C
152°C
159°C
169°C
174°C

137°C
147°C
152°C
193°C
203°C
208°C

Copyright© 2013 Eaton’s Crouse-Hinds Business

1016-1017.qxp

12/16/2013

7:26 PM

Page 1017

NVMV Series

3L

Dimensions & Weights

Champ® H.I.D. Luminaires
Dimensions:

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1017

1018-1019.qxp

3L

12/16/2013

7:26 PM

Page 1018

NVMV Series

Photometric Data

Champ® H.I.D. Luminaires

3L

Photometry - Large Housing:

1018

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1018-1019.qxp

12/16/2013

7:26 PM

Page 1019

3L

Photometric Data

NVMV Series
Champ® H.I.D. Luminaires
Photometry - Large Housing:

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1019

1020-1021.qxp

3L

12/16/2013

7:26 PM

Page 1020

NVMV Series

Photometric Data

Champ® H.I.D. Luminaires

3L

Photometry - Small Housing:

1020

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1020-1021.qxp

12/16/2013

7:27 PM

Page 1021

NVMV Series

3L

Photometric Data

Champ® H.I.D. Luminaires
Photometry - Small Housing:

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1021

1022-1023.qxp

12/16/2013

7:27 PM

Page 1022

Accessories

Champ® H.I.D. Luminaires

3L

VMV, LMV, DMV, VMV High Wattage
& N2MV Series
Globes

Reflectors

Dome – Krydon® material
G54

G24

Lamp
Watts

Luminaire Series

Type

35–150
50–175
50–250
200–400
50–175

LMV
VMV
DMV
VMV
N2MV

Heat/impact
Heat/impact
Heat/impact
Heat/impact
Heat/impact

30° Angle –
Krydon material

G303

Cat. #
resistant
resistant
resistant
resistant
resistant

G54
G24
G303
G303
G303

Lamp Watts

Luminaire Series

Dome Cat. #

Angle Cat. #

35–150
50–175
50–250
200–400
50–175

LMV
VMV
DMV
VMV
N2MV

RD636
RD70
RD739
RD739
RD739

RA636
RA70
RA739
RA739
RA740

Reflector / Lens
Guards

Etched Alzak aluminum reflector/tempered glass lens

P50 – use with
G54 globe

P21 – use with
G24 globe

P33 – use with
G303 globe

Lamp Watts

Luminaire Series

Type

Cat. #

200–400
70–250

VMV
DMV

Reflector/Lens
Reflector/Lens

GRD4
GRD4

3L

Globes – Teflon Coated
Teflon coated for increased shatter protection
Lamp Watts

Luminaire Series

Cat. #

50–175
50–175

VMV
DMV

G24 S808
G303 S808

Alzak is a registered trademark of Alcoa.
Teflon is a registered trademark of E.I. DuPont Co.

P23 – use with refractors
Lamp
Watts

Luminaire Series

Type

Cat. #

35–150
50–175
50–250
200–400
Refractors
50–175

LMV
VMV
DMV
VMV
All
N2MV

Copper-free aluminum
Copper-free aluminum
Stainless steel
Stainless steel
Stainless steel
Stainless steel

P50
P21
P33
P33
P23
P33

1022

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1022-1023.qxp

12/16/2013

7:27 PM

Page 1023

Champ® H.I.D. Luminaires

Accessories

3L

VMV, LMV, DMV, VMV High Wattage
& N2MV Series
Refractors

Safety Lighting Options
Description
Suffix
Quartz Auxiliary Lamp
QTZ
The quartz auxiliary lamp comes to full brightness instantly and
remains lit until the H.I.D. lamp attains 60–70% of full illumination.
Quartz auxiliary lamps can be used with all DMV, VMV and VMV
High Wattage series Champ® luminaires. Use for non-hazardous
applications ONLY.
VMV luminaires (50–175W) ordered with this option must use large
glass refractor optics, not compact refractors.

R2, R5, PR2, PR3, PR5

GR302, GR303, GR305

Luminaire
Series

I.E.S.
Type

Glass
Cat. #

Plastic (100W max.
non-hazardous)*
Cat. #

50–175

VMV

II
III
V

R2
R3
R5

PR2
PR3
PR5

200–400

VMV

II
III
V

GR302
GR305
GR305

50–250

DMV

II
III
V

GR302
GR303
GR305

50–175

N2MV

Lamp
Watts

100W single ended lamp – Q100CL/DC, Q100DC or 100Q/CL/DC
NOT furnished
Instant Restrike
Factory installed instant restrike device will restart a hot High
Pressure Sodium lamp after a momentary power interruption,
without the typical delay for cooling.
For use in 50–150W "LX" HPS luminaires. IR
For use in 50–100W "LX" HPS luminaires.

PGR302
PGR303
PGR305

TIR

Ballast-Gard™
BG
Ballast-Gard starter cut-out switch prevents starter pulsing after a
time delay of approximately two minutes if the lamp fails to start.
For use in 50–400 watt HPS luminaires only.

*Not available with VMV fluorescent.

I.E.S. Distribution Curves

3L

Type I

Type II

Type III

Type V

Luminaire
Series

I.E.S.
Type

Glass
Cat. #

VMV

I
III
V

G241
G243
G245
P241

Compact Refractors

Lamp
Watts
50–175

Optional stainless steel wire guard
www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1023

1024-1025.qxp

12/16/2013

3L

7:27 PM

Page 1024

Cl. I, Div. 2, Groups A, B, C, D
Maintains Cl. I, Div. 2 Suitability of Eaton's
Crouse-Hinds Champ® Series Luminaires

Photocells
V2PC, D2S and EV2IH Series

The only UL recognized photocells for Class I, Division 2 areas.
Eliminates the need for an explosionproof box!
Eaton's Crouse-Hinds factory-sealed, field installed photocells offer
reliable, dusk-to-dawn lighting control in Class I, Division 2 locations.
These photocells are ideal for walkways, security lighting, and any
other outdoor lighting application that utilizes Champ® H.I.D. lighting
luminaires.

Applications:
Eaton's Crouse-Hinds photocells are designed:
• To provide control for automatic dusk-to-dawn lighting.
• For safety by turning on outdoor luminaires in critical passageways
at night.
• To save energy by operating luminaires only when necessary.
• For walkways, parking areas, outdoor process areas, security
lighting, or any outdoor lighting application in Class I, Division 2
locations and corrosive environments.

Certifications and Compliances:

• For use with LMV, DMV, VMV, VMV High Wattage, and FMV Series
Champ® lighting luminaires (V2PC Series).
• For use on 35–400 watt H.I.D., incandescent, or fluorescent
lighting luminaires.

Class I, Division 2, Groups A, B, C, D

• For remote mounting in FS boxes (D2S Series).

• UL Standard: 844 – Hazardous (Classified) Locations

• For mounting in EIH enclosures for Class I, Division 1 applications
(EV2IH Series).

• CSA: C22.2 No. 55

Features:

EV2IH Series
• NEC/CEC:
Class I, Division 1 and 2, Groups B, C, D

• Field-installable.

Class II, Division 1, Groups E, F, G

• Solid-state design for performance and dependability.

Class II, Division 2, Groups F, G

• Factory sealed components.
Explosionproof enclosure not required for Class I, Division 2
locations.

3L

V2PC Series and D2S Series
• NEC/CEC:

Class III
• NEMA: 3, 4, 7BCD, 9EFG

• Luminaires turn on at 3 footcandles, off at 8 footcandles insuring
that the luminaires are operating only when needed.

• UL Standard: 844 – Hazardous (Classified) Locations
• CSA: C22.2 No. 30, 55

• Built-in 10 second time delay to eliminate nuisance tripping.
• Eight-year operating life.

Electrical Rating Ranges:

• Furnished with 6" stranded 600 volt color coded wire leads.

• 120, 208, 220, 240, 277 VAC

• Constructed from corrosion-resistant thermoplastic polyester.

• 50 / 60 Hz

• Available on a DS cover for use with any FS/FD box (D2S Series).

• 35–400 watt H.I.D., incandescent, or fluorescent

• Available in an EIH enclosure for use in Class I, Division 1, Groups
B*, C, and D locations (EV2IH Series). No seals required.

• V2PC20 – 3.3A max. current rating
• V2PC22 – 1.8A max. current rating

*For Group B applications, seal within 11/2" of enclosure in accordance with Section 501-5 of
the National Electric Code®.

1024

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

• V2PC27 – 1.4A max. current rating

Copyright© 2013 Eaton’s Crouse-Hinds Business

1024-1025.qxp

12/16/2013

7:27 PM

Page 1025

Photocells

Cl. I, Div. 2, Groups A, B, C, D
Maintains Cl. I, Div. 2 Suitability of Eaton's
Crouse-Hinds Champ® Series Luminaires

3L

V2PC, D2S and EV2IH Series
Ordering Information:
Photocell for field installation in lighting fixtures*
Cat. #

Voltage Range

Current Rating

V2PC20
V2PC22
V2PC27

120V, 50/60Hz
208–240V, 50/60Hz
277V, 50/60Hz

3.3A
1.8A
1.4A

Photocell in DS cover for use with FS/FD box
Cat. #

Voltage Range

D2S20
D2S208 277

120V, 50/60Hz
208V-277V

Photocell in EIH enclosure for use in Class I, Division 1, Groups B, C, and D;
Class II, Division 1, Groups E, F, and G; and Class III locations
Cat. #

Voltage Range

EV2IH20
EV2IH208 277

120V, 50/60Hz
208-277V 50/60Hz

3L

Replacement Photocell for D2S Cover or EIH
Enclosure * †
Cat. #

Voltage Range

Current Rating

V2PCT20
V2PCT208 277

120V, 50/60Hz
208V-277V 50/60Hz

8.33A
4.81A - 3.61A depending on voltage

* Must be factory installed in Canada.
† When mounting in EIH enclosures for Class I, Division 1 applications (EV21H Series) seals are not required for Groups C & D.

Options:
To order luminaire with photocell factory installed:
1. Specify luminaire dedicated supply voltage (not MT, DT, or TT)
2. Add photocell Cat. No. to fixture Cat. No. as follows:
V2PC20
V2PC22
V2PC27
Example: VMVSJ070GP/120-V2PC20 is a 120V 60Hz luminaire with
a factory installed photocell.
Note: Only the V2PC is available as a factory installed photocell.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1025

1026-1027.qxp

12/23/2013

3L

3:13 PM

Page 1026

Photocells

Cl. I, Div. 2, Groups A, B, C, D
Maintains Cl. I, Div. 2 Suitability of Eaton's
Crouse-Hinds Champ® Series Luminaires

V2PC, D2S and EV2IH Series
Dimensions:
In Inches:
V2PC

EV2IH

V2PCT

D2S

a

b

c

d

e

EV2IH

5.00

4.25

2.60

4.54

5.25

3L

Cat. #

1026

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1026-1027.qxp

12/23/2013

3:13 PM

Page 1027

High Intensity Discharge
(H.I.D.) Luminaires
Hazardous

4L

Description

Page No.

Application/Selection

see page 1028

Class I and Class II Hazardous Area Lighting
Integrally Ballasted Luminaires
EVLS Hazard•Gard® Series
EVLP Hazard•Gard® Series
EVM Hazard•Gard® Series

see pages 1029–1044
see page 1045
see page 1056

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1027

1028-1029.qxp

12/16/2013

4L

7:27 PM

Page 1028

High Intensity Discharge
(H.I.D.) Luminaires
Hazardous Application and Selection
Quick Selector Chart

Applications:
Luminaires contained in this section
are for use:
• In indoor or outdoor hazardous locations
• As general area or spot lighting
applications
• Where longer lamp life provides
desirable maintenance cost savings and
return on investment through use of
fewer luminaires, circuits and ancillary
apparatus
• Where relamping and maintenance
difficulties require longer lamp life

Considerations for
Selection:
Environmental:
• Make sure luminaire meets NEC/CEC
requirements for area in which it will be
used
Lighting levels required:
• Can luminaire accept lamp of sufficient
size to yield desired light level?

Table 500.8(C)
Identification Numbers.
Maximum Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Temp. Class
(T Code)
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Quick Selector Chart

4L

Electrical Characteristics
Series
EVLS
Hazard•Gard®

NEC Compliance

Watts

Volts

Cl. I, Groups B (with suffix GB), C, D

HPS: 50, 70, 100, 150

Multi-tap: 120, 208,
240, 277V/60Hz

Cl. II

Metal Halide: 70, 100, 175

Cl. III

Pulse Start Metal Halide: 150, 175

Ballast

480V/60Hz
Tri-tap: 120, 277,
347V/60Hz
220V/60Hz
220/240V /50Hz
EVM
Hazard•Gard®

Cl. I, Groups B, C, D

Cl. II, Groups E, F, G

50, 70, 100, 150,
175, 200, 250, 320, 400
(Mogul base)
50, 70, 100, 150,
175 (Mogul base)

120, 208, 240, 277,
347, 480, 600, MT
120, 208, 240, 277,
347, 480, 600, MT

Champ® Series
(see Section 3L)

Cl. II, Groups E, F, G

70, 100, 150, 175
(Mogul base)

120, 208, 240, 277,
347, 480, 600, MT

EVLP
Hazard•Gard®

Cl. I, Groups B, C, D

70, 100, 150, 175
(Medium base)
70, 100, 150, 175,
200, 250
(Mogul base)

120, 208, 240, 277,
347, 480, MT, TT

Cl. II, Groups E, F, G
Cl. III

70, 100
(Medium base)
70, 100, 150, 175
(Mogul base)

120, 208, 240, 277,
347, 480, MT, TT

1028

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

High power factor,
constant wattage,
reactor or
autotransformer,
integral
High power factor,
constant wattage
integral
High power factor,
constant wattage,
reactor or
autotransformer,
integral

1028-1029.qxp

12/16/2013

7:28 PM

Page 1029

EVLS Hazard•Gard®
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

A compact, affordable, explosionproof
luminaire that has the best overall
temperature performance ratings in
its class!
Eaton's Crouse-Hinds EVLS Hazard•Gard®
is perfect as a general area lighting
workhorse where space constraints exist.
EVLS Hazard•Gard® is easy to install, 175
watts and less, has select options that are
just right for your budget — AND it’s Class
I, Division 1, Group B with GB option!

Standard Materials:

Applications:

Ratings (Electrical Size):

Eaton's Crouse-Hinds EVLS Hazard•Gard
Lighting Fixures are used for general
lighting and task lighting in:
• Areas where flammable or explosive
vapors or gases are present
• Confined spaces or heavy process
industry facilities
• Petroleum refineries; chemical,
petrochemical and pharmaceutical
plants; oil terminals; gas plants
• Waste treatment facilities
• Drilling platforms and other coastal and
offshore hazardous areas

Features:

Certification &
Compliances:

4L

• Bodies, mounting modules and cast
guards – copper-free aluminum
• Wire guard – stainless steel
• Globe – heat- and impact-resistant glass
• Gaskets – silicone and neoprene

Standard Finishes:
• Epoxy powder coat paint

Sources/Wattages:
• HID Medium Base (initial offering)
HPS: 50, 70, 100, 150 watt
Metal Halide: 70, 100, 175 watt
Pulse Start Metal Halide: 150, 175 watt
Voltages:
• Multi-tap (120, 208, 240, 277V/60 Hz)
• 480V/60 Hz
• Tri-tap (120, 277, 347V/60 Hz)
• 220V/60 Hz
• 220/240V (or 230V)/50 Hz
Transformer Types:
• HX-HPF Standard
• CWA Standard on 175W
CWA Constant Wattage Autotransformer
CWI Constant Wattage Insulation
Transformer
Available for HPS and MH, for most
voltages and wattages (Additional
voltages available on request.)
Conduit Entries:
• 3/4" and 1" NPT – pendant, ceiling and
wall mount
• 11/2" NPT – stanchion

Two Start Acme Threads

4L

• Compact and rugged - a Division 1
luminaire that fits in tight spaces
• Smooth turning two start Acme threads
for mounting modules and globe
attachments save time and eliminate
installation damage
• Quick-connect design facilitates easy
installation and saves money - install and
wire the mounting module, and then
screw in luminaire to make the electrical
connection
• Best overall T-rating in the industry for a
medium-base HID lamp - use in elevated
ambient and illuminate the most volatile
areas of your facility - optimal safety in
your high-risk areas
• Factory-sealed - wired and sealed with
no external sealing fittings required in
Groups B, C, and D
• An adapter module is available for direct
connection to existing Hazard•Gard
modules such as the EV22 ceiling mount

UL and cUL Listed
Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Options:
Description
• Instant Restrike (HPS)
• Ballast-Gard™ (HPS)
• Group B Suitability

Suffix
IR
BG
GB

Accessories:
Description
• Dome Reflector
• Angle Reflector
• Guard

Suffix
RD725
RA725
EV502 or P515

UL (844) and cUL Listed (CSA C22.2
No. 137) for:
• Class I, Division 1, Groups B (with suffix
GB), C, D
• Class I, Zone 1, Group IIB + H2 (with
suffix GB)
• Class II, Class III & Simultaneous
Presence
• Wet locations (UL1598), Marine locations
(UL1598A), Type 4X, IP66

www.crouse-hinds.com

Quick Connect Design

Adapter Module Available

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1029

1030-1031.qxp

12/16/2013

7:28 PM

Page 1030

4L EVLS Hazard•Gard®

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire
Mounting Modules:

New Mounting Modules

Existing For EVI, EVLP, EVM (must use EVSA adapter)
Conduit
Catalog Number

Type
Adapter
Pendant

¾"
1"

EVSA
EVMP2
EVMP3

Ceiling & Wall Box

¾"
1"

EV22
EV33

Wall Bracket Arm

Use EV22 or EV33 box with

EV87

Stanchion
Bulkhead

1¼"
1¼"

EVMJ4
EVJ2

Conduit
¾"
1"
25mm
32mm
¾"
1"
25mm
32mm
¾"
1"
25mm
32mm
1½"
¾"
25mm

For EVLS Only
Catalog Number
EVSP2
EVSP3
EVSP25
EVSP32
EVSC2
EVSC3
EVSC25
EVSC32
EVSW2
EVSW3
EVSW25
EVSW32
EVSJ5
EVSB2
EVSB25

Family Tree:
Existing Mounting
Modules used on
EVI, EVLP, EVM
(must use EVSA adapter)
EVMP2
EVMP3

EV22
EV33

EVMJ4

EVJ2
EV22
EV33

+

EV87

EVSA ADAPTER
EVSJ5

4L

New Mounting
Modules for EVLS

EVSC2
EVSC3
EVSC25
EVSC32

EVSB2
EVSB25

EVSP2
EVSP3
EVSP25
EVSP32

EVSW2
EVSW3
EVSW25
EVSW32

EVLS (For example: EVLS9170)

RA725

RD725

EV502

1030

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

P515

Copyright© 2013 Eaton’s Crouse-Hinds Business

1030-1031.qxp

12/16/2013

7:28 PM

Page 1031

EVLS Hazard•Gard®

UL and cUL Listed
4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire
Ordering Reference Sheet:
EVLS

A

9

2

10

0

/MT

-IR

Hazard•Gard
Low-Profile Luminaire
Class I, Div. 1/Class I, Zone 1
Class II, Groups F & G
A = Pendant
Mounting Type
BX = Wall
CX = Ceiling
BH = Bulkhead
J = Stanchion
M = Mounting Module Adapter
4 = High-Press. Sodium
9 = Metal Halide

Lamp Type

Conduit Entry (specify with mtg. modules)
2 = 3/4" NPT (Pendant, Ceiling, Bulkhead & Wall mounts only)
3 = 1" NPT (Pendant, Ceiling & Wall mounts only)
5 = 1-1/2" NPT (Stanchion only)
25 = 25 mm (Pendant, Ceiling, Bulkhead & Wall mounts only)
32 = 32 mm (Pendant, Ceiling & Wall mounts only)
Note: Omit for mounting module adapter
05 = 50W HPS
07 = 70W HPS, MH
10 = 100W HPS, MH
15 = 150 HPS, MH Pulse Start
17 = 175W MH, MH Pulse Start

Lamp Wattage
by lamp type

0 = globe only, no guard
1 = stainless steel wire guard
2 = cast aluminum guard

Guard
(optional)
Voltage and Frequency
HPS
70

100

150

70

100

150 PS

MT

x

x

x

x

x

x

TT

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

DT

120

175 PS

x

x

x

x

208
220
220 50

175

4L

50

MH

x

240

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

240 50

x

x

x

x

x

x

x

277

x

x

x

x

x

x

x

x

347

x

x

x

480

x

x

x

BG = Ballast Guard (lamp type S only)
CWI = SCE Ballast
GB = Group B suitability
IR = Instant Restrike (lamp type S only)
S828 = Pulse Start (175W & 150W MH only)

x

x
x

x

x

x

x

Options

Note: BG and IR options cannot be installed together.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1031

1032-1033.qxp

12/16/2013

7:28 PM

Page 1032

4L EVLS Hazard•Gard®

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire
Temperature Performance Data:
Watts
Ambient Temp °C
High Pressure Sodium

Class I,
Div. 1 & Zone 1

Class II
(Dust) and Class III

Supply Wire Temp °C

T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4A
T4

T5
—
—
T5
—
—
T3C
—
—
T3C
—

90
90
105
90
90
105
90
90
105
90
90

T4A
—
—
T4
—
—
—
—
—

90
90
105
90
90
105
90
90
90

40
55
65
40
55
65
40
55
65
40
55

50W

70W

100W

150W

Metal Halide (including Pulse Start [PS] as indicated)
40
55
65
40
55
65
40
40
40

70W

100W
150 PS
175W
175 PS

T5
T4A
T4A
T4A
T4A
T4
T3C
T3C
T3C

Net Luminaire Weights (lbs.):
Luminaire Series
High Pressure Sodium
EVLS4

Lamp Watts

Weight with Globe &
Wire Guard
18.5
21.5
22.5
24

70W
100W
150 PS
175W
175 PS

Add for cast guard:

20
20.5
23
23
23
1

Add for mounting modules:
Pendant
Ceiling
Stanchion
Bulkhead
Wall
Adapter

2
3.5
3
2.5
5.5
2

Add for reflectors:
Dome
Angle

1.5
2

4L

50W
70W
100W
150W

Metal Halide
EVLS9

1032

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1032-1033.qxp

12/16/2013

7:28 PM

Page 1033

EVLS Hazard•Gard®
Compact & Rugged, Class I,
Zone 1, Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2 (with
suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed
4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information — High Pressure Sodium:

Wattage

Hub Size

No Guard

PENDANT
Wire Guard

Cast Guard

No Guard

BULKHEAD
Wire Guard

Cast Guard

/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

EVLSA42050
EVLSA43050

EVLSA42051
EVLSA43051

EVLSA42052
EVLSA43052

EVLSBH42050

EVLSBH42051

EVLSBH42052

EVLSA425050
EVLSA432050
EVLSA42070
EVLSA43070

EVLSA425051
EVLSA432051
EVLSA42071
EVLSA43071

EVLSA425052
EVLSA432052
EVLSA42072
EVLSA43072

EVLSBH425050

EVLSBH425051

EVLSBH425052

EVLSBH42070

EVLSBH42071

EVLSBH42072

EVLSA425070
EVLSA432070
EVLSA42100
EVLSA43100

EVLSA425071
EVLSA432071
EVLSA42101
EVLSA43101

EVLSA425072
EVLSA432072
EVLSA42102
EVLSA43102

EVLSBH425070

EVLSBH425071

EVLSBH425072

EVLSBH42100

EVLSBH42101

EVLSBH42102

EVLSA425100
EVLSA432100
EVLSA42150
EVLSA43150

EVLSA425101
EVLSA432101
EVLSA42151
EVLSA43151

EVLSA425102
EVLSA432102
EVLSA42152
EVLSA43152

EVLSBH425100

EVLSBH425101

EVLSBH425102

EVLSBH42150

EVLSBH42151

EVLSBH42152

EVLSA425150
EVLSA432150

EVLSA425151
EVLSA432151

EVLSA425152
EVLSA432152

EVLSBH425150

EVLSBH425151

EVLSBH425152

3

50W

70W

100W

150W

Complete
Standard Voltage Ballasts
catalog
number
as follows: NEC/UL

CEC/CSA (cUL)

Multi-tap

120V

480V

Suffix

/MT

/120

/480

/TT

/120

www.crouse-hinds.com

/208CWI

Export
240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50

/240 50

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4L

Voltage

Tri-Tap 120V 208V
CWI

1033

1034-1035.qxp

12/16/2013

7:30 PM

Page 1034

4L EVLS Hazard•Gard®

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire

Ordering Information — High Pressure Sodium (Cont'd):

Wattage

/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3

50W

70W

100W

4L

150W

WALL
Wire Guard

Cast Guard

No Guard

CEILING
Wire Guard

Cast Guard

EVLSBX42050
EVLSBX43050

EVLSBX42051
EVLSBX43051

EVLSBX42052
EVLSBX43052

EVLSCX42050
EVLSCX43050

EVLSCX42051
EVLSCX43051

EVLSCX42052
EVLSCX43052

EVLSBX425050
EVLSBX432050
EVLSBX42070
EVLSBX43070

EVLSBX425051
EVLSBX432051
EVLSBX42071
EVLSBX43071

EVLSBX425052
EVLSBX432052
EVLSBX42072
EVLSBX43072

EVLSCX425050
EVLSCX432050
EVLSCX42070
EVLSCX43070

EVLSCX425051
EVLSCX432051
EVLSCX42071
EVLSCX43071

EVLSCX425052
EVLSCX432052
EVLSCX42072
EVLSCX43072

EVLSBX425070
EVLSBX432070
EVLSBX42100
EVLSBX43100

EVLSBX425071
EVLSBX432071
EVLSBX42101
EVLSBX43101

EVLSBX425072
EVLSBX432072
EVLSBX42102
EVLSBX43102

EVLSCX425070
EVLSCX432070
EVLSCX42100
EVLSCX43100

EVLSCX425071
EVLSCX432071
EVLSCX42101
EVLSCX43101

EVLSCX425072
EVLSCX432072
EVLSCX42102
EVLSCX43102

EVLSBX425100
EVLSBX432100
EVLSBX42150
EVLSBX43150

EVLSBX425101
EVLSBX432101
EVLSBX42151
EVLSBX43151

EVLSBX425102
EVLSBX432102
EVLSBX42152
EVLSBX43152

EVLSCX425100
EVLSCX432100
EVLSCX42150
EVLSCX43150

EVLSCX425101
EVLSCX432101
EVLSCX42151
EVLSCX43151

EVLSCX425102
EVLSCX432102
EVLSCX42152
EVLSCX43152

EVLSBX425150
EVLSBX432150

EVLSBX425151
EVLSBX432151

EVLSBX425152
EVLSBX432152

EVLSCX425150
EVLSCX432150

EVLSCX425151
EVLSCX432151

EVLSCX425152
EVLSCX432152

Hub Size No Guard

Complete
Standard Voltage Ballasts
catalog
number
as follows: NEC/UL
CEC/CSA (cUL)
208V
Voltage
Multi-tap 120V 480V Tri-Tap 120V
CWI

240V
CWI

480V
CWI

600V
CWI

Suffix

/240CWI

/480CWI

/600CWI /220

1034

/MT

/120

www.crouse-hinds.com

/480

/TT

/120

US: 1-866-764-5454

/208CWI

CAN: 1-800-265-0502

Export
220V
60 Hz

Copyright© 2013 Eaton’s Crouse-Hinds Business

220V
50 Hz

240V
50 Hz

/220 50

/240 50

1034-1035.qxp

12/16/2013

7:30 PM

Page 1035

EVLS Hazard•Gard®

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed
4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information — High Pressure Sodium (Cont'd):

ADAPTER

STANCHION

Wattage Hub Size
50W
70W
100W
150W

Adapter
11/2"
Adapter
11/2"
Adapter
11/2"
Adapter
11/2"

No Guard

Wire Guard

Cast Guard

EVLSJ45050

EVLSJ45051

EVLSJ45052

EVLSJ45070

EVLSJ45071

EVLSJ45072

EVLSJ45100

EVLSJ45101

EVLSJ45102

EVLSJ45150

EVLSJ45151

EVLSJ45152

No Guard

Wire Guard

Cast Guard

Luminaire less
mounting module
and guard

EVLSM4050

EVLSM4051

EVLSM4052

EVLS4050

EVLSM4070

EVLSM4071

EVLSM4072

EVLS4070

EVLSM4100

EVLSM4101

EVLSM4102

EVLS4100

EVLSM4150

EVLSM4151

EVLSM4152

EVLS4100

Complete
STANDARD VOLTAGE BALLASTS
catalog
number as
NEC/UL
CEC/CSA (cUL)
follows:

Export

Voltage

Multi-tap 120V 480V

Tri-Tap 120V 208V
CWI

Suffix

/MT

/TT

/120

/480

/120

/208CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

/240CWI

/480CWI

/600CWI /220

220V
50 Hz

240V
50 Hz

/220 50

/240 50

4L

Photometrics - EVLS High Pressure Sodium
Fixture with Globe and Domed Reflector (less guard) EVLSA42150RD725
Lamp: 150W/B17 High Pressure Sodium (HPS)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1035

1036-1037.qxp

12/16/2013

7:30 PM

Page 1036

4L EVLS Hazard•Gard®
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Photometrics - EVLS High Pressure Sodium:
Fixture with Globe and Guard EVLSA42151
Lamp: 150W/B17 High Pressure Sodium (HPS)

Photometrics - EVLS High Pressure Sodium:

4L

Fixture with Globe and Angled Reflector (less guard) EVLSA42150RA725
Lamp: 150W/B17 High Pressure Sodium (HPS)

1036

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

UL and cUL Listed
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

1036-1037.qxp

12/16/2013

7:30 PM

Page 1037

EVLS Hazard•Gard®
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed
4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information — Pulse Start Metal Halide:

Wattage Hub
Size

150W

175W

3/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

No Guard

PENDANT
Wire Guard

Cast Guard

No Guard

BULKHEAD
Wire Guard

Cast Guard

EVLSA92150-S828
EVLSA93150-S828

EVLSA92151-S828
EVLSA93151-S828

EVLSA92152-S828
EVLSA93152-S828

EVLSBH92150-S828

EVLSBH92151-S828

EVLSBH92152-S828

EVLSA925150-S828
EVLSA932150-S828
EVLSA92170-S828
EVLSA93170-S828

EVLSA925151-S828
EVLSA932151-S828
EVLSA92171-S828
EVLSA93171-S828

EVLSA925152-S828
EVLSA932152-S828
EVLSA92172-S828
EVLSA93172-S828

EVLSBH925150-S828 EVLSBH925151-S828

EVLSBH925152-S828

EVLSBH92170-S828

EVLSBH92172-S828

EVLSA925170-S828 EVLSA925171-S828 EVLSA925172-S828
EVLSA932170-S828 EVLSA932171-S828 EVLSA932172-S828

EVLSBH925170-S828 EVLSBH925171-S828

EVLSBH92171-S828

EVLSBH925172-S828

Ordering Information — Pulse Start Metal Halide:

4L

Wattage Hub
Size
3
/4"
1"
11/2"
150W
25 mm
32 mm
3
/4"
1"
175W
11/2"
25 mm
32 mm

No Guard

WALL
Wire Guard

Cast Guard

No Guard

CEILING
Wire Guard

EVLSBX92150-S828
EVLSBX93150-S828

EVLSBX92151-S828
EVLSBX93151-S828

EVLSBX92152-S828
EVLSBX93152-S828

EVLSCX92150-S828
EVLSCX93150-S828

EVLSCX92151-S828 EVLSCX92152-S828
EVLSCX93151-S828 EVLSCX93152-S828

EVLSBX925150-S828
EVLSBX932150-S828
EVLSBX92170-S828
EVLSBX93170-S828

EVLSBX925151-S828
EVLSBX932151-S828
EVLSBX92171-S828
EVLSBX93171-S828

EVLSBX925152-S828
EVLSBX932152-S828
EVLSBX92172-S828
EVLSBX93172-S828

EVLSCX925150-S828
EVLSCX932150-S828
EVLSCX92170-S828
EVLSCX93170-S828

EVLSCX925151-S828
EVLSCX932151-S828
EVLSCX92171-S828
EVLSCX93171-S828

Cast Guard

EVLSCX925152-S828
EVLSCX932152-S828
EVLSCX92172-S828
EVLSCX93172-S828

EVLSBX925170-S828 EVLSBX925171-S828 EVLSBX925172-S828 EVLSCX925170-S828 EVLSCX925171-S828 EVLSCX925172-S828
EVLSBX932170-S828 EVLSBX932171-S828 EVLSBX932172-S828 EVLSCX932170-S828 EVLSCX932171-S828 EVLSCX932172-S828

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1037

1038-1039.qxp

12/16/2013

7:30 PM

Page 1038

4L EVLS Hazard•Gard®
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information — Pulse Start Metal Halide (Cont'd):

STANCHION

4L

Hub
Wattage Size
Adapter
3
/4"
1"
150W
11/2"
25 mm
32 mm
Adapter
3
/4"
1"
175W
11/2"
25 mm
32 mm

No Guard

Wire Guard

ADAPTER

Cast Guard

Wire Guard

Cast Guard

EVLSM9150-S828 EVLSM9151-S828 EVLSM9152-S828 EVLS9150-S828

EVLSJ95150-S828 EVLSJ95151-S828 EVLSJ95152-S828

EVLSM9170-S828 EVLSM9171-S828 EVLSM9172-S828 EVLS9100-S828
EVLS9170-S828
EVLSJ95170-S828 EVLSJ95171-S828 EVLSJ95172-S828

Complete
catalog
Standard Voltage Ballasts
number as
NEC/UL
follows:
Multi-tap
120V
Voltage

480V

Suffix

/480

1038

No Guard

Luminaire
less
mounting
module and
guard

/MT

www.crouse-hinds.com

/120

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1038-1039.qxp

12/16/2013

7:30 PM

Page 1039

EVLS Hazard•Gard®

Cl. I, Div. 1, Groups B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed
4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information — Metal Halide:

PENDANT
Wattage

70W

100W

175W†

Hub Size
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

BULKHEAD

No Guard
EVLSA92070
EVLSA93070

Wire Guard
EVLSA92071
EVLSA93071

Cast Guard
EVLSA92072
EVLSA93072

No Guard
EVLSBH92070

Wire Guard
EVLSBH92071

Cast Guard
EVLSBH92072

EVLSA925070
EVLSA932070
EVLSA92100
EVLSA93100

EVLSA925071
EVLSA932071
EVLSA92101
EVLSA93101

EVLSA925072
EVLSA932072
EVLSA92102
EVLSA93102

EVLSBH925070

EVLSBH925071

EVLSBH925072

EVLSBH92100

EVLSBH92101

EVLSBH92102

EVLSA925100
EVLSA932100
EVLSA92170
EVLSA93170

EVLSA925101
EVLSA932101
EVLSA92171
EVLSA93171

EVLSA925102
EVLSA932102
EVLSA92172
EVLSA93172

EVLSBH925100

EVLSBH925101

EVLSBH925102

EVLSBH92170

EVLSBH92171

EVLSBH92172

EVLSA925170
EVLSA932170

EVLSA925171
EVLSA932171

EVLSA925172
EVLSA932172

EVLSBH925170

EVLSBH925171

EVLSBH925172

†Export only.

Complete
Standard Voltage Ballasts
catalog
number
as follows: NEC/UL
Multi-tap 120V 480V Tri-Tap

120V

Suffix

/MT

/120

/208CWI

/480

/TT

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

230V*
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50

/230 50

/240 50

*Available for 175W only.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1039

4L

Voltage

208V
CWI

/120

Export

CEC/CSA (cUL)

1040-1041.qxp

12/16/2013

4L

7:31 PM

Page 1040

EVLS Hazard•Gard®

Cl. I, Div. 1, Group B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed
Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information — Metal Halide (Cont'd):

WALL
Wattage

70W

100W

175W†

Hub
Size
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

CEILING

No Guard
EVLSBX92070
EVLSBX93070

Wire Guard
EVLSBX92071
EVLSBX93071

Cast Guard
EVLSBX92072
EVLSBX93072

No Guard
EVLSCX92070
EVLSCX93070

Wire Guard
EVLSCX92071
EVLSCX93071

Cast Guard
EVLSCX92072
EVLSCX93072

EVLSBX925070
EVLSBX932070
EVLSBX92100
EVLSBX93100

EVLSBX925071
EVLSBX932071
EVLSBX92101
EVLSBX93101

EVLSBX925072
EVLSBX932072
EVLSBX92102
EVLSBX93102

EVLSCX925070
EVLSCX932070
EVLSCX92100
EVLSCX93100

EVLSCX925071
EVLSCX932071
EVLSCX92101
EVLSCX93101

EVLSCX925072
EVLSCX932072
EVLSCX92102
EVLSCX93102

EVLSBX925100
EVLSBX932100
EVLSBX92170
EVLSBX93170

EVLSBX925101
EVLSBX932101
EVLSBX92171
EVLSBX93171

EVLSBX925102
EVLSBX932102
EVLSBX92172
EVLSBX93172

EVLSCX925100
EVLSCX932100
EVLSCX92170
EVLSCX93170

EVLSCX925101
EVLSCX932101
EVLSCX92171
EVLSCX93171

EVLSCX925102
EVLSCX932102
EVLSCX92172
EVLSCX93172

EVLSBX925170
EVLSBX932170

EVLSBX925171
EVLSBX932171

EVLSBX925172
EVLSBX932172

EVLSCX925170
EVLSCX932170

EVLSCX925171
EVLSCX932171

EVLSCX925172
EVLSCX932172

4L

†Export only.

Complete
catalog
number as
follows:

Standard Voltage Ballasts

Voltage

Multi-tap 120V

480V

Tri-Tap

120V

208V
CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

230V*
50 Hz

240V
50 Hz

Suffix

/MT

/480

/TT

/120

/208CWI

/240CWI

/480CWI

/600CWI

/220

/220 50

/230 50

/240 50

NEC/UL

/120

CEC/CSA (cUL)

Export

*Available for 175W only.

1040

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1040-1041.qxp

12/16/2013

7:31 PM

Page 1041

Cl. I, Div. 1, Group B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS Hazard•Gard®
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed
Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

4L

Ordering Information — Metal Halide (Cont'd):

STANCHION

Wattage
70W
100W
175W†

Hub
Size
Adapter
11/2"
Adapter
11/2"
Adapter
3
/4"
11/2"

No
Guard

Wire
Guard

ADAPTER
Cast
Guard

EVLSJ95070 EVLSJ95071

EVLSJ95072

EVLSJ95100 EVLSJ95101

EVLSJ95102

EVLSJ95170 EVLSJ95171

No Guard
Wire Guard
EVLSM9070 EVLSM9071

Cast Guard
EVLSM9072

Luminaire less
mounting module
and guard
EVLS9070

EVLSM9100 EVLSM9101

EVLSM9102

EVLS9100

EVLSM9170 EVLSM9171

EVLSM9172

EVLS9100
EVLS9170

EVLSJ95172

†Export only.

Complete
catalog
number as
follows:

Standard Voltage Ballasts
NEC/UL

CEC/CSA (cUL)

Voltage

Multi-tap

120V

480V

Tri-Tap

120V

208V
CWI

Suffix

/MT

/120

/480

/TT

/120

/208CWI

Export

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

230V*
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50 /230 50 /240 50

*Available for 175W only.

EVLS Metal Halide:

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4L

Fixture with Globe and Domed Reflector (less guard) EVLSA92170RD725
Lamp: 150W/ED17 Metal Halide (MH)

1041

1042-1043.qxp

4L

12/16/2013

7:31 PM

Page 1042

EVLS Hazard•Gard®
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS Metal Halide:
Fixture with Globe and Guard EVLSA92171
Lamp: 175W/ED17 Metal Halide (MH)

EVLS Metal Halide:

4L

Fixture with Globe and Angled Reflector (less guard) EVLSA92170RA725
Lamp: 175W/ED17 Metal Halide (MH)

1042

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

UL and cUL Listed
Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

1042-1043.qxp

12/16/2013

7:31 PM

Page 1043

Cl. I, Div. 1, Group B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS Hazard•Gard®
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed
Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

4L

Dimensions - Shown with new mounting modules:
10.97

3.16

15°

16.47

16.36
16.97

17.85

.61
8.47

.61

BULKHEAD MOUNT

CEILING MOUNT

4.11

15.45

3.61

25°

17.43
8.28

17.18

16.82

4L

.61

13.78
15.45

8.47

STANCHION MOUNT

.61

PENDANT MOUNT

9.51

16.78
17.39

.61

8.47

WALL MOUNT

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1043

1044-1045.qxp

4L

12/16/2013

7:31 PM

Page 1044

EVLS Hazard•Gard®

Cl. I, Div. 1, Group B
(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed
Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Dimensions - Shown with existing mounting modules plus EVSA Adapter:
11 15/16"

15”
18 5/8"
19 3/16"
21 5/8"

CEILING MOUNT EV22, EV33
BULKHEAD MOUNT EVJ2

18 7/16"

19 1/16"
19 11/16"

20 1/16"
19 9/16"

4L

25”

8 7/16"

STANCHION MOUNT EVMJ4
9 1/2"

PENDANT MOUNT EVMP2, EVMP3

3 5/16"

19"

19 5/8"

WALL MOUNT BRACKET EV87

1044

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1044-1045.qxp

12/16/2013

7:31 PM

Page 1045

EVLP Low Profile Hazard•Gard®
(H.I.D.) Luminaires

Cl. I, Div. 1, Groups B
(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with suffix – GB), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

Medium and Mogul Base

Marine & Wet
Locations
3, 3R, 4, 4X; IP66

4L

Applications:

Standard Materials:

Eaton's Crouse-Hinds Low Profile
Hazard•Gard® luminaires are used in:
• Areas where flammable or explosive
vapors or gases are present
• Hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
• Petroleum refineries, chemical,
petrochemical and pharmaceutical
plants, oil terminals, gas plants and other
heavy process industry facilities
• Waste treatment facilities
• Drilling platforms and other coastal and
offshore hazardous areas

• Mounting modules, cover, ballast
housing, globe holder – copper-free
aluminum
• Globe – heat and impact resistant glass
• Exterior hardware – stainless steel
• Reflectors (dome & angle) – Krydon®
fiberglass-reinforced polyester

• Copper-free aluminum – Corro-free™
powdered epoxy
• Krydon – white
• Stainless steel guard

Features and Benefits:

Ratings (Electrical/Size):
Certifications and
Compliances:
• NEC and CEC:
Class I, Division 1, Groups B
(with suffix GB), C, D – All Wattages
Class I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA – All Wattages
Class II and Class III
• UL Standards:
844, Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards
C22.2 No. 137

Sources/Wattage:
• Medium Base 70–150W HPS, 70–175W
MH
• Mogul Base 70–150W HPS, 70–250W
MH
Voltages:
• Medium & Mogul H.I.D.
120V 60Hz
Multi-tap (120, 208, 240, 277V 60Hz)
Tri-tap (120, 277, 347V 60Hz)
480V 60Hz
Other voltages – consult Eaton's
Crouse-Hinds
Conduit Entries:
• 3/4", 1" NPT – pendant, wall bracket,
ceiling
• 11/4" NPT – stanchion

Options:
Description
Suffix
• Group B suitability ........................................................................................... GB
• Ballast-Gard™ (HPS only) ................................................................................. BG
• Instant restrike (Mogul Base only) ...................................................................
IR
70–150W LX HPS
Cannot use with BG Option
• Fused (not suitable for marine applications).................................................... S658*
• Quartz auxiliary lighting
(Mogul Base only) ............................................................................................ QTZ
Cannot use with IR option
Uses 100W single ended double contract lamp
Quartz lamp not included
• Factory assembled with lamps ........................................................................
FA

4L

• Small, compact size is perfect where low
mounting restrictions are a concern.
• Two start Acme threaded construction
allows for easier assembly, installation
and maintenance.
• Lightweight copper-free aluminum
housing with powdered epoxy finish for
superior corrosion resistance.
• All exterior hardware is corrosionresistant stainless steel.
• Four mounting arrangements: pendant,
ceiling, wall bracket and stanchion suit
any lighting layout.
• Wide range of light sources and
wattages to meet specific lighting needs.
• Marine and NEMA 4X construction
suitable for outdoor, hose down, marine
and corrosive environments.
• Integral ballast for lowest installed cost.
• High power factor (90%+) ballasts allows
more fixtures per circuit.
• Uses same mounting modules as the
standard Hazard•Gard® for easy
retrofitting when the EVLP is the
preferred choice.
• Internally fluted glass globe reduces
glare and distributes light evenly – ideal
for adverse enviroments typical of
industrial facilities.
• Krydon® construction dome and angle
reflectors – won’t rust, corrode, dent,
chip or peel
• Now available in components – luminaire
body, mounting module, guard,
reflectors – allowing for easy stocking for
Quick Ship requirements.

Standard Finishes:

*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.

Accessories:
Description

Cat. #

Dome reflector
Angle reflector

RD739
RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1045

1046-1047.qxp

4L

12/16/2013

7:31 PM

Page 1046

EVLP Low Profile
Hazard•Gard®

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Cl. I, Div. 1, Groups B
(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

Medium Base
Ordering Information:

Pendant
Hub
With Guard
Watt Size (In.) Cat. #

Wall Bracket

Ceiling

Stanchion

Luminaire Body
Less Mounting
Module & Guard

With Guard
Cat. #

With Guard
Cat. #

With Guard
Cat. #

Cat. #

High Pressure Sodium
/4
1
11/4

EVLPA142071
EVLPA143071

EVLPBX142071
EVLPBX143071

EVLPCX142071
EVLPCX143071

/4
100W 1
11/4

EVLPA142101
EVLPA143101

EVLPBX142101
EVLPBX143101

EVLPCX142101
EVLPCX143101

/4
150W 1
11/4

EVLPA142151
EVLPA143151

EVLPBX142151
EVLPBX143151

EVLPCX142151
EVLPCX143151

3

70W
Pendant Mount

3

3

EVLP14070
EVLPJ144071
EVLP14100
EVLPJ144101
EVLP14151
EVLPJ144151

Pulse Start Metal Halide
3
/4
150W 1
11/4

EVLPA192151 S828 EVLPBX192151 S828 EVLPCX192151 S828
EVLPA193151 S828 EVLPBX193151 S828 EVLPCX193151 S828

/4
175W 1
11/4

EVLPA192171 S828 EVLPBX192171 S828 EVLPCX192171 S828
EVLPA193171 S828 EVLPBX193171 S828 EVLPCX193171 S828

3

†Wall Bracket
Mount

EVLP19150 S828
EVLPJ194151 S828
EVLP19175 S828
EVLPJ194171 S828

Metal Halide
3
/4
1
11/4

EVLPA192071
EVLPA193071

/4
100W 1
11/4

EVLPA192101
EVLPA193101

/4
175W 1
11/4

EVLPA192171
EVLPA193171

70W

4L

3

3

EVLPBX192071
EVLPBX193071

EVLPCX192071
EVLPCX193071

EVLP19070
EVLPJ194071

EVLPBX192101
EVLPBX193101

EVLPCX192101
EVLPCX193101

EVLP19100
EVLPJ194101

EVLPBX192171
EVLPBX193171

EVLPCX192171
EVLPCX193171

EVLP19175
EVLPJ194171

†Ceiling Mount

Complete Catalog Number as follows:
Standard Voltage Ballasts – 60Hz
1.

NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

Optional Voltage Ballasts – 50 or 60Hz
*CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

230V 50Hz
/230 50

2. 150W HPS Luminaires only

Stanchion Mount

●
●

55V lamps – add suffix "LX"
100V lamps – add suffix "CE"

†Ceiling and bracket mounts have 4 hubs: 3 are plugged.
*CWI Isolated Ballasts are only available for high pressure sodium and 175W metal halide (non pulse start) luminaires.

1046

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

240V 50Hz
/240 50

1046-1047.qxp

12/16/2013

7:31 PM

Page 1047

EVLP Low Profile
Hazard•Gard®

Cl. I, Div. 1, Groups B (GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G; Class III

Mogul Base

4L

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Ordering Information:

Pendant
With
Guard
Hub
Watt Size(In.) Cat. #

Wall Bracket
With Guard
Cat. #

Ceiling
With Guard
Cat. #

Stanchion
With Guard
Cat. #

Luminaire Body
Less Mounting
Module & Guard
Cat. #

High Pressure Sodium
3
/4
1
11/4

EVLPA042071
EVLPA043071

EVLPBX042071
EVLPBX043071

EVLPCX042071
EVLPCX043071

/4
100W 1
11/4

EVLPA042101
EVLPA043101

EVLPBX042101
EVLPBX043101

EVLPCX042101
EVLPCX043101

/4
150W 1
11/4

EVLPA042151
EVLPA043151

EVLPBX042151
EVLPBX043151

EVLPCX042151
EVLPCX043151

70W

3

Pendant Mount

3

EVLP04070
EVLPJ044071
EVLP04100
EVLPJ044101
EVLP04150
EVLPJ044151

Pulse Start Metal Halide
3
/4
150W 1
11/4

EVLPA092151S828 EVLPBX092151S828 EVLPCX092151S828
EVLPA093151S828 EVLPBX093151S828 EVLPCX093151S828

/4
175W 1
11/4

EVLPA092171S828 EVLPBX092171S828 EVLPCX092171S828
EVLPA093171S828 EVLPBX093171S828 EVLPCX093171S828

/4
200W 1
11/4

EVLPA092201S828 EVLPBX092201S828 EVLPCX092201S828
EVLPA093201S828 EVLPBX093201S828 EVLPCX093201S828

/4
250W 1
11/4

EVLPA092251S828 EVLPBX092251S828 EVLPCX092251S828
EVLPA093251S828 EVLPBX093251S828 EVLPCX093251S828

3

3

†Wall Bracket
Mount

3

EVLP09150S828
EVLPJ094151S828
EVLP09170S828
EVLPJ094171S828
EVLP09201S828
EVLPJ094201S828
EVLP09250S828
EVLPJ094251S828

Metal Halide
3
/4
1
11/4

EVLPA092071
EVLPA093071

/4
100W 1
11/4

EVLPA092101
EVLPA093101

EVLPBX092101
EVLPBX093101

EVLPCX092101
EVLPCX093101

/4
175W 1
11/4

EVLPA092171
EVLPA093171

EVLPBX092171
EVLPBX093171

EVLPCX092171
EVLPCX093171

/4
250W 1
11/4

EVLPA092251
EVLPA093251

70W

3

3

†Ceiling Mount

EVLPCX092071
EVLPCX093071

EVLP09070
EVLPJ094071
EVLP09100
EVLPJ094101

4L

3

EVLPBX092071
EVLPBX093071

EVLP09170
EVLPJ094171

EVLPBX092251
EVLPBX093251

EVLPCX092251
EVLPCX093251

EVLP09250
EVLPJ094251

Complete Catalog Number as follows:
Standard Voltage Ballasts – 60Hz
1.
Voltage
Multi Tap
Suffix
/MT

NEC/UL
120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

Optional Voltage Ballasts – 50 or 60Hz
*CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

Stanchion Mount

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

120V
/120

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

230V 50Hz
/230 50

240V 50Hz
/240 50

2. 150W HPS Luminaires only
• 55V lamps – add suffix "LX"
• 100V lamps – add suffix "CE"
Example: EVLPA043151/MT-LX

†Ceiling and wall bracket mounts have 4 hubs: 3 are plugged.
*CWI Isolated Ballasts are only available for high pressure sodium and 175W–250W metal halide (non pulse start) luminaires.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1047

1048-1049.qxp

12/16/2013

7:32 PM

Page 1048

EVLP Low Profile
Hazard•Gard®

4L

Ordering by Components
EVLP Luminaires are available in components.
A
•
•
•

complete luminaire consists of:
Mounting Module
Luminaire Body
Guard, Dome Reflector or Angle Reflector

Mounting Modules:
Type
Pendant

Conduit

Cat. #

3

/4"
1"

EVMP2
EVMP3

/4"
1"

EV22
EV33

3

Ceiling & Wall Box
Wall Bracket Arm

Use EV22 or EV33 box with EV87

EV87

Stanchion

11/4"

EVMJ4

Guards
Medium
Mogul

EV511
EV512

Reflectors
Dome
Angle

RD739
RA739
Pendant

Ceiling

Stanchion

Ceiling

Wall Bracket

EVMP2
EVMP3

EV22
EV33

EVMJ4

EV22
EV33

EV87 & EV22 or EV33

4L

Luminaire Body
EVLP0 Series – H.I.D. Mogul Lamp
EVLP1 Series – H.I.D. Medium Lamp

1048

www.crouse-hinds.com

Guards

Dome Reflector

Angle Reflector

EV511
EV512

RD739

RA739

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1048-1049.qxp

12/16/2013

7:32 PM

Page 1049

4L

Temperature Performance Data

EVLP Low Profile
Hazard•Gard®

Medium Base Lamp Luminaires:

Maximum Ambient

Watts

Class I, Group B
(w/GB suffix)
Groups C, D
40°C
55°C

65°C

Class II, Groups E, F, G
Class III
Simultaneous
Presence
40°C

High Pressure Sodium

70W
100W
150W

T5
T4A
T4

T4A
T4A
T3C

T4A
T4
—

T4A
T4
—

90°C
90°C
90°C

Metal Halide
(including pulse start)

70W
100W
150W
175W

T5
T3C
T3C
T3C

T4A
T3C
T3B
T3B

T4A
—
—
—

T4
—
—
—

85°C
90°C
90°C
90°C

Supply Wire °C

Mogul Base Lamp Luminaires:
Class II, Groups E, F, G
Class III
Simultaneous
Presence

Class I, Group B
(w/GB suffix)
Groups C, D
Maximum Ambient

Watts

40°C

55°C

65°C

40°C

Supply Wire °C

High Pressure Sodium

70W
100W
150W

T6
T5
T4A

T5
T4A
T4

T5
—
—

T5
T4A
T4

90°C
90°C
90°C

Metal Halide
(including pulse start)

70W
100W
150W
175W
200W
250W

T6
T5
T4
T4
T3C
T3C

T5
T4A
T3C
T3C
—
—

T5
T4A
—
—
—
—

T5
T4A
T3C
T3C
—
—

85°C
90°C
90°C
90°C
90°C
90°C

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1049

1050-1051.qxp

12/16/2013

4L

7:32 PM

Page 1050

EVLP Low Profile
Hazard•Gard®
Dimensions and Weights

Dimensions
In Inches:

4L

Medium Base
Mogul Base

A

B

C

D

E

F

13.92
15.69

12.73
14.69

16.50
18.25

16.71
18.46

20.59
22.34

19.36
21.30

Weights
(lbs.):
Luminaire w/guard
Source
High Pressure Sodium

Watts

Medium

Mogul

70
100
150

34
36
36.5

36.5
38.5
39

70
100
150
175
200
250

33.5
34.5
36
36
—
—

36
37
38.5
38.5
40.5
40.5

Metal Halide

Medium

Mogul

Add Mounting Modules:
Pendant
Ceiling
Bracket
Stanchion

1
2
4.5
2.5

1
2
4.5
2.5

Add For Reflectors:
RA739
RD739
Deduct for Wire Guard

1
1
0.5

1
1
0.5

1050

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1050-1051.qxp

12/16/2013

7:32 PM

Page 1051

Photometric Data

EVLP Low Profile
Hazard•Gard®

4L

Medium Base
Medium Base
Luminaire with Globe and Guard
EVLPA143151 Lamp: 150W/B17 High Pressure Sodium (HPS)

Medium Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA143150RD Lamp: 150W/B17 High Pressure Sodium (HPS)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1051

1052-1053.qxp

12/16/2013

4L

7:32 PM

Page 1052

EVLP Low Profile
Hazard•Gard®

Photometric Data

Medium and Mogul Base
Medium Base
Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVLPA143150RA Lamp: 150W/B17 High Pressure Sodium (HPS)

Mogul Base
Luminaire with Globe and Guard
4L

EVLPA043151 Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

1052

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1052-1053.qxp

12/16/2013

7:32 PM

Page 1053

EVLP Low Profile
Hazard•Gard®

4L

Photometric Data

Mogul Base
Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA043150RD Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

Mogul Base
Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVLPA043150RA Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1053

1054-1055.qxp

12/16/2013

4L

7:32 PM

Page 1054

Photometric Data

EVLP Low Profile
Hazard•Gard®
Mogul Base

Mogul Base
Luminaire with Globe and Guard
EVLPA093171 Lamp: 175W/ED28 Metal Halide (MH)

Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
4L

EVLPA093170RD Lamp: 175W/ED28 Metal Halide (MH)

1054

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1054-1055.qxp

12/16/2013

7:32 PM

Page 1055

4L

Photometric Data

EVLP Low Profile
Hazard•Gard®
Mogul Base
Mogul Base

Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVLPA093170RA Lamp: 175W/ED28 Metal Halide (MH)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1055

1056-1057.qxp

12/23/2013

4L

3:14 PM

Page 1056

EVM Hazard•Gard®
H.I.D. Luminaires
Mogul Base
Factory Sealed (Groups C, D)

Cl. I, Div. 1, Groups B (GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with suffix – GB), IIB IIA
Cl. II, Div. 1, Groups E, F, G; Class III

Applications:

Options:

Hazard•Gard® luminaires are used in:
• Heavy process industries where
flammable or explosive vapors, gases or
combustible dusts are present
• Hazardous areas, both indoors and
outdoors where long life and low
maintenance costs are desired
• Petroleum refineries, chemical,
petrochemical and other heavy process
industry facilities
• Paint spray facilities
• Hazardous locations requiring elevated
ambient capability

• NEC and CEC:
Class I, Division 1, Groups B
(with suffix GB), C, D
Class I, Zone 1, Groups IIB + H2 (with
suffix GB), IIB, IIA
100W max – Paint Spray Suitability
175W max – Class II, Class III
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137

Description
Suffix
• Fused – to protect ballast and
capacitor against abnormal line
conditions. (Not suitable for
marine applications).................... S658§†
• Instant restrike – enables a hot
HPS lamp to immediately
restrike after a momentary
loss of arc due to voltage
fluctuation or power outage. It
has no effect on the warm-up
period of a cold lamp (50-150W
LX HPS only). ..............................
IR*
• Quartz auxiliary lighting – quartz
lamp comes to full brightness
instantly upon restoration of
power to provide emergency
illumination during the normal
restrike period of the H.I.D. lamp
(for use with ED28 lamp).
(Quartz lamp not included; use
100 W single-ended lamp –
Q100DC, Q100CL/DC, or
100Q/CL/DC.) ............................. QTZ‡
• Ballast-Gard™ – to eliminate
the normally continuous high
voltage pulsing in the event
of a cycling lamp, inoperative
lamp, or no lamp in the
socket extending the life of the
ballast. (For use with 50-400W
HPS lamps.) ................................
BG*
• Group B suitability – luminaires
suitable for use in Class I,
Group B hazardous (classified)
locations......................................
GB
• Hazard•Gard® supplied with
trunnion arm for floodlighting
applications. For use on pendant
mount luminaires only. See
Floodlight Section .......................
S812

Standard Materials:

Size Ranges:

• Mounting modules, cover, ballast
housing, guard, globe ring – copper-free
aluminum
• Globe – heat and impact resistant glass
• Exterior hardware – stainless steel
• Lamp socket – porcelain with stainless
steel screw shell
• Reflectors – dome and angle: Krydon
fiberglass-reinforced polyester material;
high bay: Alzak aluminum

• 3/ 4", 1" and 11/ 4" hubs (see ordering
information – see pages 1057–1058)

Features:

4L

Paint Spray
(100W max)
Marine & Wet
Locations
3, 3R, 4, 4X; IP66

• Luminaire is factory wired; power is
fed through "wireless" connection
block which serves as a mechanical
seal between conduit and ballast
compartments, eliminating the need
for an external, field installed seal.
The result is fast, easy installation.
• Dome and 30° angle reflectors made of
Krydon® material – won't rust, corrode,
dent, chip or peel (order separately –
see page 1059).
• High bay reflectors of Alzak® aluminum
for high wattage applications.
• Internally fluted glass globes
reduce glare and provide comfortable
viewing light.
• Wide range of light sources and
wattages to meet specific lighting needs
– 50 – 400W high pressure sodium
(HPS); 70 – 400W metal halide (MH).
• High power factor (90%+) ballasts
reduce power costs – allow more
luminaires per circuit.
• Four mounting arrangements to suit any
lighting layout – pendant, ceiling, wall
bracket and stanchion.
• Paint spray booth suitability on 50 to
100 watt luminaires provides efficient,
economical H.I.D. lighting for areas
where paint residue may accumulate
on luminaires.
• Elevated ambient capability permits
reliable operation at high ambient
temperature. Selected luminaires are
suitable for ambient temperature up
to 75°C.
• Integral ballasts – separate ballasts are
not required. Lowest installed cost.
• Factory sealed, porcelain, mogul
base socket.

1056

www.crouse-hinds.com

US: 1-866-764-5454

Certifications and
Compliances:

Standard Finishes:
• Copper-free aluminum – epoxy
powder coat
• Krydon – high reflectance white
• Alzak – natural (anodized)

CAN: 1-800-265-0502

Electrical Rating Ranges:
• 120, 208, 240, 277, 347, 480,
600, multi-tap*
• 50 to 400 watts
*IR and BG options cannot be used together.
†When ordering fuses for luminaires, option S658, you
must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.
‡Can be used with BG option.
§CSA Certified are not available with multi-tap ballast or
S658 fuse option.
Alzak is a registered trademark of ALCOA.

Copyright© 2013 Eaton’s Crouse-Hinds Business

1056-1057.qxp

12/23/2013

3:14 PM

Page 1057

50–400W EVM
Hazard•Gard®
H.I.D. Luminaires

Cl. I, Div. 1, Groups B (GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA
Cl. II, Div. 1, Groups E, F, G; Class III

Mogul Base
Factory Sealed (Groups C, D)

Pendant Luminaires
Hub
Without
Size
Guard
Watts (In.)
Cat. #
High Pressure Sodium
3
/4
EVMA42050
1
EVMA43050
50
1
1 /4

Wall Bracket Luminaires
Without
Guard
Cat. #

Ceiling Luminaires

With
Guard
Cat. #

Without
Guard
Cat. #

EVMA42051 EVMBX42050
EVMA43051 EVMBX43050

EVMBX42051
EVMBX43051

EVMCX42050 EVMCX42051
EVMCX43050 EVMCX43051

3

70

/4
1
11/4

EVMA42070 EVMA42071 EVMBX42070
EVMA43070 EVMA43071 EVMBX43070

EVMBX42071
EVMBX43071

EVMCX42070 EVMCX42071
EVMCX43070 EVMCX43071

3

100

/4
1
11/4

EVMA42100 EVMA42101 EVMBX42100
EVMA43100 EVMA43101 EVMBX43100

EVMBX42101
EVMBX43101

EVMCX42100 EVMCX42101
EVMCX43100 EVMCX43101

3

150

/4
1
11/4

EVMA42150 EVMA42151 EVMBX42150
EVMA43150 EVMA43151 EVMBX43150

EVMBX42151
EVMBX43151

EVMCX42150 EVMCX42151
EVMCX43150 EVMCX43151

3

200

/4
1
11/4

EVMA42200 EVMA42201 EVMBX42200
EVMA43200 EVMA43201 EVMBX43200

EVMBX42201
EVMBX43201

EVMCX42200 EVMCX42201
EVMCX43200 EVMCX43201

3

250

/4
1
11/4

EVMA42250 EVMA42251 EVMBX42250
EVMA43250 EVMA43251 EVMBX43250

EVMBX42251
EVMBX43251

EVMCX42250 EVMCX42251
EVMCX43250 EVMCX43251

400

/4
1
11/4

EVMA42400 EVMA42401 EVMBX42400
EVMA43400 EVMA43401 EVMBX43400

EVMBX42401
EVMBX43401

EVMCX42400 EVMCX42401
EVMCX43400 EVMCX43401

3

With
Guard
Cat. #

4L

Paint Spray
(100W max)
Marine & Wet
Locations
3, 3R, 4, 4X; IP66

With
Guard
Cat. #

Stanchion Luminaires (25°)
Without
Guard
Cat. #

With
Guard
Cat. #

EVMJ44050 EVMJ44051

EVMJ44070 EVMJ44071

EVMJ44100 EVMJ44101

EVMJ44150 EVMJ44151

EVMJ44200 EVMJ44201

EVMJ44250 EVMJ44251

Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows:
Standard Voltage Ballasts – 60Hz
NEC/UL
1.

Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Optional Voltage Ballasts – 50 or 60Hz
CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

600V CWI
/600CWI

EXPORT
220V 60Hz
/220

2.

150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix "CE"

3.

Options - Add the Required Options Suffixes, see page 1056, in alpha-numeric order.

www.crouse-hinds.com

120V
/120

220V 50Hz
/220 50

US: 1-866-764-5454

230V 50Hz
/230 50

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1057

4L

EVMJ44400 EVMJ44401

1058-1059.qxp

12/16/2013

4L

7:33 PM

Page 1058

Cl. I, Div. 1, Groups B
(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

70–400W EVM
Hazard•Gard®
H.I.D Luminaires
Factory Sealed (Groups C, D)

Pendant Luminaires
Watts

Hub
Size (In.)

Without Guard
Cat. #

Pulse Start Metal Halide
3
EVMA92150 S828
/4
EVMA93150 S828
1
150
1
1 /4

4L

EVMCX92151 S828

EVMCX93150 S828

EVMCX93151 S828

EVMCX93170 S828

EVMCX93171 S828

/4
1
11/4

EVMA92200 S828

EVMA92201 S828

EVMBX92200 S828 EVMBX92201 S828

EVMCX92200 S828

EVMCX92201 S828

EVMA93200 S828

EVMA93201 S828

EVMBX93200 S828 EVMBX93201 S828

EVMCX93200 S828

EVMCX93201 S828

/4
1
11/4

EVMA92250 S828

EVMA92251 S828

EVMBX92250 S828 EVMBX92251 S828

EVMCX92250 S828

EVMCX92251 S828

EVMA93250 S828

EVMA93251 S828

EVMBX93250 S828 EVMBX93251 S828

EVMCX93250 S828

EVMCX93251 S828

/4
1
11/4

EVMA92320 S828

EVMA92321 S828

EVMBX92320 S828

EVMBX92321 S828 EVMCX92320 S828

EVMCX92321 S828

EVMA93320 S828

EVMA93321 S828

EVMBX93320 S828

EVMBX93321 S828 EVMCX93320 S828

EVMCX93321 S828

/4
1
11/4

EVMA92400 S828

EVMA92401 S828

EVMBX92400 S828 EVMBX92401 S828

EVMCX92400 S828

EVMCX92401 S828

EVMA93400 S828

EVMA93401 S828

EVMBX93400 S828 EVMBX93401 S828

EVMCX93400 S828

EVMCX93401 S828

EVMA92070

EVMA92071

EVMBX92070

EVMBX92071

EVMCX92070

EVMCX92071

EVMA93070

EVMA93071

EVMBX93070

EVMBX93071

EVMCX93070

EVMCX93071

/4
1
11/4

EVMA92100

EVMA92101

EVMBX92100

EVMBX92101

EVMCX92100

EVMCX92101

EVMA93100

EVMA93101

EVMBX93100

EVMBX93101

EVMCX93100

EVMCX93101

/4
1
11/4

EVMA92170

EVMA92171

EVMBX92170

EVMBX92171

EVMCX92170

EVMCX92171

EVMA93170

EVMA93171

EVMBX93170

EVMBX93171

EVMBX93170

EVMCX93171

/4
1
11/4

EVMA92250

EVMA92251

EVMBX92250

EVMBX92251

EVMCX92250

EVMCX92251

EVMA93250

EVMA93251

EVMBX93250

EVMBX93251

EVMCX93250

EVMCX93251

/4
1
11/4

EVMA92400

EVMA92401

EVMBX92400

EVMBX92401

EVMCX92400

EVMCX92401

EVMA93400

EVMA93401

EVMBX93400

EVMBX93401

EVMCX93400

EVMCX93401

3

Complete the Catalog Number by Adding Voltage
and Options Suffixes as Follows:
Standard Voltage Ballasts – 60Hz
NEC/UL
1.

Voltage
Suffix

Multi Tap
/MT

Dual-Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual-Tap
/DT

120V
/120

Optional Voltage Ballasts – 50 or 60Hz
*CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
220V 60Hz 220V 50Hz 230V 50Hz
/220
/220 50
/230 50

2.

150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix "CE"

3.

Options - Add the Required Options Suffixes, see page 1056, in alpha-numeric order.

240V 50Hz
/240 50

*CWI Isolated Ballasts are only available for 175W–400W metal halide (non pulse start) luminaires.

1058

www.crouse-hinds.com

Stanchion Luminaires (25°)
Without Guard
Cat. #

EVMJ94150 S828

EVMBX93170 S828 EVMBX93171 S828

3

400

EVMCX92150 S828

EVMBX93150 S828 EVMBX93151 S828

EVMA93171 S828

3

250

EVMBX92150 S828 EVMBX92151 S828

EVMA93151 S828

EVMA93170 S828

3

175

EVMA92151 S828

EVMCX92171 S828

Metal Halide
3
/4
1
70
11/4
100

With Guard
Cat. #

EVMCX92170 S828

3

400

Without Guard
Cat. #

EVMBX92170 S828 EVMBX92171 S828

3

320

With Guard
Cat. #

EVMA92171 S828

3

250

Without Guard
Cat. #

EVMA92170 S828

3

200

With Guard
Cat. #

Ceiling Luminaires

/4
1
11/4
3

175

Wall Bracket Luminaires

Paint Spray (100W max.)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

With Guard
Cat. #

EVMJ94151 S828

EVMJ94170 S828

EVMJ94171 S828

EVMJ94200 S828

EVMJ94201 S828

EVMJ94250 S828

EVMJ94251 S828

EVMJ94320 S828

EVMJ94321 S828

EVMJ94400 S828

EVMJ94401 S828

EVMJ94070

EVMJ94071

EVMJ94100

EVMJ94101

EVMJ94170

EVMJ94171

EVMJ94250

EVMJ94251

EVMJ94400

EVMJ94401

1058-1059.qxp

12/16/2013

7:33 PM

Page 1059

Accessories and
Temperature Performance Data

EVM Hazard•Gard® H.I.D.
Luminaires

4L

Reflectors

Dome

30° Angle

High Bay
Type

Cat. #

Dome
30° Angle
High Bay

RD739
RA739
EV3912

Temperature Performance Data
Maximum Ambient

Class I

Simultaneous
Presence

Paint
Spray
Booth

Supply
Wire

65°C

75°C

40°C

40°C

40°C

°C

T6
T5
T4A
T4
T4
—
—

T5
T4A
T4A
—
—
—
—

T4
T4
T4
T3C
—
—
—

T4
T4
T4
T3C
—
—
—

T4A
T4A
T4A
—
—
—
—

90
90
90
90
90
90
90

T3
T3
—
—
—
—
—
—

T3C
T3C
T3C
T3C
—
—
—
—

T3C
T3C
T3C
T3C
—
—
—
—

T4A
T4A
—
—
—
—
—
—

90
90
90
90
90
90
90
90

Metal Halide (Including Pulse Start)
70
T6
T6
T5
100
T5
T5
T4A
150
T4A
T4
T4
175
T4A
T4
T4
200
T4
T3C
—
250
T4
T3C
—
320
T3A
—
—
400
T3A
—
—

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4L

Watts
40°C
55°C
High Pressure Sodium
50
T6
T6
70
T6
T6
100
T5
T5
150
T4A
T4A
200
T4A
T4A
250
T4
T3C
400
T3C
—

Class II
(E, F, G)

1059

1060-1061.qxp

12/16/2013

7:33 PM

Page 1060

EVM Hazard•Gard® H.I.D.
Luminaires

4L

Dimensions and Weights
Dimensions:

Luminaire Net Weights:
H.I.D.
Source

Lamp
Watts

50
70
100
High
150 (55V)
Pressure 150 (100V)
Sodium
200
250
400
70
100
175
250
400

Metal
Halide

Luminaire Only
with Globe and
Guard (lbs.)
40
40
44
45
44
46
46
55
39
39
42
43
51

Type
Lbs.
Type
Add for Mounting Modules:
Pendant
Bracket
1
Ceiling
Stanchion
2

Lbs.
41/4
21/4

4L

Add for Reflectors:
RD739
13/4
RA739
2
EV3912
21/2
Deduct: 11/2 lbs. for luminaire without guard.

Guard
EV503
EV5140

All – Reflectors

100, 175, 250W MV 50, 70, 100, All luminaires with QTZ option
150W HPS 70, 100, 175, 250W
and 200, 250, 400W HPS
MH
400W MV & MH

Type
EVMA
EVMBX
EVMCX
EVMJ

1060

a
25 /16
277/8
24
2211/16
1

www.crouse-hinds.com

b

f

26
2813/16
2415/16
241/8

27 /16
301/8
261/4
251/4

US: 1-866-764-5454

g
5

CAN: 1-800-265-0502

28 /4
311/16
273/16
261/8
1

Dome –

High
Bay –

30°
Angle –

c

d

e

23 /8
2611/16
2213/16
253/8
7

Copyright© 2013 Eaton’s Crouse-Hinds Business

26 /16
293/4
253/8
2711/16
7

289/16
313/8
271/2
283/4

1060-1061.qxp

12/16/2013

7:33 PM

Page 1061

EVM Hazard•Gard® H.I.D.
Luminaires

Photometric Data

Lamp: 150W/E-23-1/2 high pressure sodium (HPS)
Total bare lamp lumens: 16,000

Coefficient of Utilization

Luminaire With Globe and Without Guard
Note: Photometric data was
developed using a 150 watt
clear high pressure sodium
lamp (16,000 lumens). For
other clear lamps, use the
following conversion factors
(multipliers): 50W HPS – .25;
70W HPS – .40; 100W HPS –
.59. Multipliers are for use
with candela curve only.
Luminaire spacing ratio is
0.80.

Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.695
.644
.599

.579
.509
.450

.494
.417
.356

.410
.326
.262

.382
.305
.246

70

50
30
10

.659
.613
.570

.549
.484
.431

.469
.397
.341

.387
.311
.251

.363
.291
.236

50

50
30
10

.592
.555
.522

.491
.439
.393

.419
.360
.312

.344
.279
.229

.327
.265
.218

30

50
30
10

.531
.502
.474

.438
.396
.358

.373
.325
.284

.304
.250
.207

.292
.240
.200

10

50
30
10

.476
.451
.429

.390
.355
.325

.331
.291
.257

.267
.222
.184

.260
.217
.181

0

0

.399

.295

.230

.159

9

10

80

50
30
10

.342
.266
.212

.306
.234
.184

.278
.209
.160

.265
.198
.153

.233
.168
.127

70

50
30
10

.324
.254
.202

.292
.223
.176

.265
.201
.155

.253
.191
.149

.222
.163
.123

50

50
30
10

.292
.232
.187

.263
.203
.162

.240
.184
.143

.231
.177
.139

.203
.150
.114

30

50
30
10

.262
.211
.172

.236
.186
.148

.218
.167
.132

.210
.162
.129

.185
.138
.105

10

50
30
10

.234
.190
.156

.213
.169
.135

.195
.152
.121

.191
.149
.118

.167
.125
.096

0

0

.135

.116

.103

.103

.081

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1061

4L

.159

Room Cavity Ratio
6
7
8

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

4L

1062-1063.qxp

12/16/2013

7:33 PM

Page 1062

EVM Hazard•Gard® H.I.D.
Luminaires

4L

Photometric Data

Lamp: 150W/E-23-1/2 high pressure sodium (HPS)
Total bare lamp lumens: 16000

Lamp: 150W/E-23-1/2 high pressure sodium (HPS)
Total bare lamp lumens: 16000

Luminaire With Globe, Hi-Bay Reflector
and Without Guard

Luminaire With Globe, Dome Reflector and
Without Guard

Note: Photometric data was
developed using a 150 watt clear
high pressure sodium lamp
(16,000 lumens). For other clear
lamps, use the following
conversion factors (multipliers):
50W HPS – .25; 70W HPS – .40;
100W HPS – .59. Multipliers are
for use with candela curve only.

Note: Photometric data was
developed using a 150 watt
clear high pressure sodium
lamp (16,000 lumens). For
other clear lamps, use the
following conversion factors
(multipliers): 50W HPS – .25;
70W HPS – .40; 100W HPS –
.59. Multipliers are for use with
candela curve only.

Luminaire spacing ratio is 1.00.

Luminaire spacing ratio is 1.20.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

4L

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

4

5

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.668
.651
.636

.618
.592
.569

.573
.542
.517

.531
.495
.468

.494
.455
.427

80

50
30
10

.716
.689
.666

.637
.596
.561

.568
.519
.480

.507
.452
.410

.455
.398
.355

70

50
30
10

.655
.639
.625

.608
.583
.564

.566
.536
.513

.525
.491
.464

.487
.452
.425

70

50
30
10

.700
.675
.653

.624
.585
.555

.559
.512
.476

.498
.447
.407

.446
.393
.353

50

50
30
10

.629
.616
.606

.587
.568
.550

.550
.525
.505

.511
.482
.459

.476
.446
.422

50

50
30
10

.668
.648
.631

.598
.567
.539

.538
.498
.466

.479
.435
.400

.432
.385
.349

30

50
30
10

.606
.597
.588

.569
.554
.539

.535
.514
.497

.498
.474
.454

.466
.438
.418

30

50
30
10

.640
.625
.610

.575
.549
.526

.518
.485
.457

.463
.425
.394

.417
.376
.344

10

50
30
10

.586
.578
.570

.553
.539
.528

.522
.504
.489

.487
.466
.449

.457
.433
.413

10

50
30
10

.615
.602
.590

.554
.532
.513

.500
.472
.448

.447
.415
.388

.404
.369
.339

0

0

.560

.517

.479

.439

.404

0

0

.575

.498

.434

.373

.326

% Reflectance
Eff. Ceil. Wall

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.460
.420
.394

.427
.388
.361

.396
.358
.330

.369
.330
.303

.328
.288
.262

70

50
30
10

.455
.418
.391

.423
.385
.359

.392
.356
.329

.366
.328
.303

50

50
30
10

.444
.412
.388

.414
.380
.357

.385
.352
.328

30

50
30
10

.436
.407
.385

.406
.377
.354

10

50
30
10

.428
.402
.382

0

0

.373

1062

www.crouse-hinds.com

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.413
.355
.316

.373
.318
.280

.339
.285
.246

.312
.258
.221

.275
.222
.187

.325
.288
.262

70

50
30
10

.405
.352
.312

.368
.314
.277

.334
.283
.245

.308
.256
.221

.271
.222
.187

.360
.325
.301

.320
.285
.261

50

50
30
10

.392
.345
.309

.356
.307
.274

.324
.277
.243

.299
.252
.219

.264
.217
.185

.379
.348
.326

.354
.322
.300

.315
.282
.259

30

50
30
10

.380
.338
.306

.345
.303
.270

.316
.272
.241

.291
.247
.217

.257
.214
.183

.400
.373
.352

.373
.345
.324

.348
.319
.298

.311
.280
.258

10

50
30
10

.369
.331
.301

.337
.298
.267

.307
.267
.238

.283
.244
.215

.251
.210
.181

.343

.315

.290

.249

0

0

.289

.255

.226

.203

.170

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1062-1063.qxp

12/16/2013

7:33 PM

Page 1063

5L

Fluorescent Luminaires
Hazardous and Non-Hazardous

Description

Page No.

Application/Selection

see page 1064

General Purpose Luminaires
VF Vaporgard™ Series

see page 1065

Non-metallic Luminaires
NFL Series
N2MVF

see pages 1096–1098
see pages 1078–1082

Hazardous Area Luminaires
CPMVF
DMVF
eLLB20 Series
eLLK Series
EVLPF
EVF Series
EVFDR Series
EVFT Illuminator™ Series
FVN Series
FVS Series
nLLK Series
VMVF

see
see
see
see
see
see
see
see
see
see

pages 1068–1069
pages 1071–1077
pages 1109–1111
pages 1099–1102
pages 1083–1088
see page 1112
pages 1116–1117
pages 1092–1095
pages 1106–1108
pages 1089–1091
pages 1103–1105
see page 1070

5L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1063

1064-1065.qxp

5L

12/16/2013

7:33 PM

Page 1064

Fluorescent Lighting Luminaires
Hazardous and Non-hazardous
Application and Selection
Quick Selector Chart

Applications:

Considerations for Selection:

• For use in hazardous or non-hazardous
areas (as shown in the Quick Selector
Chart below)
• Low operating cost
• High light output per watt
• Low brightness
• Low glare
• Uniform light
• Instant illumination

Having made the determination that a
fluorescent luminaire is required, the remaining
selection is the type of luminaire (i.e., number
and kind of lamps) and placement of
luminaire. To determine the number of
luminaires:
1. Determine Cavity Ratios for room, ceiling
and floor
2. Determine Coefficient of Utilization
3. Determine Light Loss
4. Determine Lamp Lumens required =
Footcandles x Area
Coefficient of Utilization x Light Loss Factor
5. Determine number of luminaires required =
Total Lamp Lumens Required
Lamp Lumens per Luminaire

Table 500.8(C)
Identification Numbers
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Temp.
Class
(T Code)
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Quick Selector Chart
NEC – Hazardous
Area Compliance
Cl. I, Division 2, Groups A, B, C, D

Lamp
Watts
9

Volts
120

No. of
Lamps
2

NFL

Cl. I, Division 2, Groups A, B, C, D

32, 40

120–277V 50–60Hz

1, 2

FVN

Cl. I, Division 2, Groups A, B, C, D;
Cl. II, Groups F, G;
Cl. III

32, 40, 60

120, 277, 220 / 240 50 or 60Hz

2, 3

EVF

Cl. I, Groups C, D;
Cl. II, Groups E, F, G

32, 40, 60, 110

120, 277, 347, 220 / 240 50 or 60Hz

1, 2, 3, 4

EVFDR

Cl. I, Groups C, D;
Cl. II, Groups E, F, G

32, 40, 60, 110

120, 277, 220 / 240 50 or 60Hz

2

EVFT

Cl. I, Groups B, C, D;
Cl. II, Groups E, F, G;
Cl. III

39

120, 277, 220 / 240 50 or 60Hz

2, 4

FVS

Cl. I, Division 2, Groups B, C, D;
Cl. II, Groups E, F, G;
Cl. III

40

120–277V, 50–60Hz or
347V, 60Hz

2

DMVF

Cl. I, Division 2, Groups A, B, C, D;
Cl. II, Groups E, F, G;
Cl. III; Simultaneous Presence

26, 32, 42

120–277V, 50–60Hz or
347V, 60Hz

2, 3

N2MVF

Cl. I, Division 2, Groups A, B, C, D;
Class II, Groups F, G;
Class III; Simultaneous Presence

26, 32

120–277V, 50–60Hz or
347V, 60Hz

2

EVLP

Cl. I, Division 1, Groups (B), C, D;
Cl. II, Groups E, F, G;
Cl. III; Simultaneous Presence

26, 32

120–277V, 50–60Hz or
347V, 60Hz

2

CPMVF

Cl. I, Division 2, Groups A, B, C, D

26, 32, 42

120–277V, 50–60Hz or
347V, 60Hz

2

eLLB 20

Cl. I, Division 2, Groups A, B, C, D;
Cl. I, Zone 1, Group IIC;
Cl. II, Division 2, Groups F, G

17, 32

120–240V, 50–60Hz
110–230VDC

2

eLLK

Cl. I, Zone I & Division 2;
Cl. II, Division 2

32

120–254V

2

nLLK

Cl. I, Division 2, Groups A, B, C, D;
Cl. I, Zone 2 AEx nA II;
Cl. II, Division 2, Groups F, G

17, 32

120–277V, 60Hz

2

5L

Series
VF

1064

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1064-1065.qxp

12/16/2013

7:33 PM

Page 1065

VF Series Vaporgard™
Fluorescent Luminaires

5L

Cl. I, Div. 2, Groups A, B, C, D*
Cl. I, Zone 2 IIC*
Wet Locations
3, 3R

Applications:

Accessories:

VF Series Vaporgard Fluorescent Lighting
Luminaires are used:
• Indoors or outdoors in industrial
locations where enclosed and gasketed
luminaires are required
• Where the energy efficiency and long life
of single twin tube compact fluorescent
lamps are desired
• Where luminaires may be subject to wet,
damp, dirty locations
• Where vibration and rough usage are a
problem
• To retrofit existing Vaporgard
incandescent luminaires
• In tunnels, building entrances, utility
rooms, hallways and similar locations
• With clear or colored globes to illuminate
or mark critical locations or processes

• See next page for complete listing

Luminaire Net Weights:
Fixture
Type
VFA
VFHF
VFHBF

43/4
5
71/4

5
51/4
71/2

• Copper-free aluminum – powder epoxy
finish
• Krydon material – high reflectance white

Lbs.
1

Temperature Performance
Data:
Class I, Max.
Supply Minimum
Lamp Div. 2
Ambient Wire °C Operating
9W

T3B

40°C

75°C

-4°C
(25°F)

Electrical Ratings:
• Input voltage – 120 VAC, 60 hertz
• Wattages: two 9 watt lamps

Dimensions
In Inches:

VFC

Certifications and
Compliances:

VFH

5L

• Compact size and light weight allow
adaptation and easy installation in many
industrial applications
• Cast copper-free aluminum (less than 0.4
of 1% copper) construction and epoxy
powder finish provide excellent
resistance to corrosion
• Variety of mounting arrangements to suit
any lighting layout – pendant, ceiling,
wall bracket, angle stanchion, through
feed, box mount
• VFH luminaire components can be
installed on existing Vaporgard
incandescent components and standard
stamped metal boxes
• Fixtures available for use with two
compact 9 watt fluorescent lamps
• Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity; will not chip, peel,
dent, rust, or corrode (order separately –
see pages 1066–1067)
• Glass globes are internally fluted and
stippled to reduce glare and provide
even light distribution; exteriors are
smooth to shed dust
• All luminaires 120 VAC only!
• Grounding wire for safety

2-Lamp
Luminaire
With Globe
& Guard (lbs.)

Type
Lbs.
Type
Add for Reflectors:
Dome
30° Angle
1
Deduct: 1/2 lb. for P21 Guard

Standard Finishes:

Features:

1-Lamp
Luminaire
With Globe &
Guard (lbs.)

VFHA

VFHF

VFHBF

VFHT

VFA

• UL Standard: 1598, 844
• CSA Standard: C22.2 No. 137

Standard Materials:
• Bodies and guards – copper-free
aluminum (less than 0.4 of 1%)
• Globes – clear or colored, glass or
plastic
• Reflectors – Krydon fiberglass-reinforced
polyester material

*All mountings except stanchion.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1065

1066-1067.qxp

12/16/2013

5L

7:34 PM

Page 1066

Cl. I, Div. 2, Groups A, B, C, D†
Cl. I, Zone 2 IIC†
Wet Locations
NEMA 3, 3R

VF Series Vaporgard™
Fluorescent Luminaires

Twin Tube Fluorescent with G24 Clear Glass Globe and P21 Guard (lamps not included)

Pendant
Mount

Luminaire
Watts

Wall Mount
(w/Box)

Wall Mount
(No Box)

Pendant
Hub
Mount
Size (In.) Cat. #

Ceiling
Mount
Cat. #

Wall
Mount
(w/Box)
Cat. #

/2
/4
1
11/4

VFHF122GP
VFHF222GP

VFHBF122GP VFHT122GP
VFHBF222GP VFHT222GP

VFA122GP
VFA222GP
VFA322GP

1
3

2 Lamps, 9W Each

Ceiling
Mount

Wall
Mount
(No Box)
Cat. #

Angle
Stanchion
Angle
Stanchion
Mount*
Cat. #

Through
Box Mount &
Feed Mount
Retrofit
Through
Feed
Mount
Cat. #

Box
Mount &
Retrofit
Cat. #

VFC122GP
VFC222GP

VFH122GP

VFHA422GP

VF Series with Colored Glass Globes or Plastic Globes
To obtain:
• Substitute appropriate globe designation for "G" in above Cat. Nos.

Accessories and Components
Reflectors

Globes

Globe
Color
Clear
Green
Blue
Red
Amber

Cat. #
RD71
RA71

5L

Type
Dome (Cannot be used with wall
mount luminaires)
30° Angle

Guards

Glass
Cat. #
G24
G25
G26
G27
G28

Plastic
Cat. #*
G63
G65

Guard
For use with glass
globes only

Guard
Cat. #
P21

G67

Junction Boxes and Bracket Bodies

VXF – 4 Hubs, 3 Plugs
VXF – 4 Hubs, 3 Plugs
Hub Size (In.)

Cat. #

/2
/4

VXF10
VXF20

1
3

VXT – 3 Hubs, 2 Plugs
VXT – 3 Hubs, 2 Plugs
Hub Size (In.)
Cat. #
/2
/4

VXT10
VXT20

1
3

VXFT – 5 Hubs, 4 Plugs
VXFT – 5 Hubs, 4 Plugs
Hub Size (In.)

Cat. #

/2
/4

VXFT10
VXFT20

1
3

VXA – Stanchion Mount
(Non-hazardous Locations)
VXA – Stanchion Mount (Non-hazardous Locations)
Hub Size (In.)
Cat. #
11/4

VXT-K1
Mounting Adapter Kit
Description
Cat. #
Allows for the mounting of non-Eaton's Crouse-Hinds outlet boxes to the VXT20 wall
VXT K1
mount bracket and VXH ceiling mount bracket

*For non-hazardous locations.
†All mountings except stanchion.

1066

www.crouse-hinds.com

VXA4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Page 1067
7:34 PM
12/16/2013
1066-1067.qxp

150W
VDA15
VDA25
VDA35

200W
VDA12
VDA22
VDA32

300W
VDA13
VDA23
VDA33

PENDANT
VDA/VFA

FLUORESCENT
VFA122
VFA222
VFA322

300W
VDC23

FLUORESCENT
VFC222
VXH12 VXH13

200W
VFH122

FLUORESCENT

300W

VXH15

150W

G24

P21

PLATE
0305729
VXT-K1

GASKET
0305017

150W
VXHBF25

5L

200W
VXHBF22

RA71

300W
VXHBF23

CLEAR HEAT RESISTING

WALL & JUNCTION BOX
VXHBF/VFHBF

300W GLOBE
WITH GUARD

G251 GLOBE
&
P22 GUARD

ADAPTER KIT FOR MOUNTING VXT20 AND
VXH15, VXH12, VXH13, VFH122 TO
4" OULET BOX (BY OTHERS)

FLUORESCENT
VFHF222

G34

RD71

CLEAR HEAT RESISTING

300W GLOBE
WITHOUT GUARD

300W
VXHF23

VXF20
VXFT20 (ORDER SEPARATELY)

VXH15
VXH12
VXH13
VFH122

200W
VXHF22

VXHF/VFHF

BOX MOUNTING

150W
VXHF25

VXH1/VFH1

BOX MOUNTING

RA64

(NO GUARD AVAILABLE WHEN
ORDERED WITH PLASTIC GLOBE)

G24 CLEAR HEAT RESISTING
G25 GREEN
G26 BLUE
G27 RED
G28 AMBER
G63 CLEAR PLASTIC POLYCARBONATE
G65 GREEN PLASTIC POLYCARBONATE
G67 RED PLASTIC POLYCARBONATE

FLUORESCENT &
200W
GLOBE & GUARD

VDC/VFC

P50

G54

150W
GLOBE & GUARD

THRU FEED

150W
200W
VDC25 VDC22

G54 CLEAR HEAT RESISTING
G55 GREEN
G56 BLUE
G57 RED
G58 AMBER

RD64

VXT20

VXH15
VXH12
VXH13
VFH122

VFHBF222

FLUORESCENT

0305016

GASKET

VXF20
VXFT20
300W
200W
150W
VXHT25 VXHT22 VXHT23

WALL MOUNT
VXHT/VFHT

FLUORESCENT
VFHT222

150W

300W

VXA4

VXH15
VXH12
VXH13
VFH122

200W

VXHA45 VXHA42 VXHA43

VFHA422

FLUORESCENT

VXHA4/VFHA4

ANGLE ADAPTER
STANCHION MOUNT

1067

Copyright© 2013 Eaton’s Crouse-Hinds Business

CAN: 1-800-265-0502

US: 1-866-764-5454

www.crouse-hinds.com

5L
Family Tree

VF Series Vaporgard™
Fluorescent Luminaires

1068-1069.qxp

5L

12/16/2013

7:34 PM

Page 1068

CPMVF Champ-Pak™
Compact Fluorescent
Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP56

Applications:
CPMVF Champ-Pak™ luminaires are used:
• Indoor and outdoor wall mounting or vertical surface mounting
where minimal luminaire depth is required in:
– Manufacturing plants and heavy industrial facilities
– Industrial process facilities such as refineries, chemical,
petrochemical, pharmaceutical and platforms
– Waste or sewage treatment plants
– Offshore, dockside and harbor installations
• For security and safety lighting in industrial facilities for lighting of
loading docks, tunnels, and stairways
• For marine, wet location, hose down, and corrosive environments

Features and Benefits:
• Unique compact shallow-profile design mounts virtually anywhere
• Side hinged cover with two screw closing for easy installation and
maintenance
• Gray Corro-free™ epoxy powder coat two-piece housing provides
superior corrosion resistance
• Unique stainless steel wire guard accessory attaches without any
additional hardware for easy installation and maintenance
• Glass refractor provides uniform light distribution to eliminate glare
• Silicon gaskets make luminaire suitable for NEMA 4X, marine
environments
• High power factor ballasts (+90%) are standard, which allow more
luminaires per circuit

5L

Certifications and Compliances:
• NEC and CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III & Simultaneous Presence (Class I, Division 2
and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844, 2279 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15

Standard Materials:
• Luminaire housing and door frame assembly – copper-free
aluminum
• External hardware – stainless steel
• Lens – heat- and impact-resistant refractor style glass
• Gaskets – silicon rubber
• Reflector – aluminum light sheet
• Wire guard – stainless steel

Electrical Rating Ranges:
•
•
•
•

Wattages: two 26, 32, or 42 watt lamps
120–277V, 50–60Hz
347V, 60Hz
12, 24, and 125VDC (Consult Eaton's Crouse-Hinds)

Options:
Description
Restricted Breathing Construction...........................................
Class I, Division 2 & Zone 2 Suitability
Cooler Operating Temperatures (T-Numbers)

Certified for IEC Zone 2 ........................................................... S826TB
Furnished with:
Terminal Block
Crimp Terminals
Factory Assembled with Lamp.................................................

FA

Fused - protects ballast and capacitors against abnormal
line conditions ..........................................................................
(Not for use in Canada)
(Not for marine use)

S658

Accessories:
Description
Photocell for Field Installation
• 120V, 50/60Hz ...................................................................
• 208–240V, 50/60Hz ...........................................................
• 277V, 50/60Hz ...................................................................
Stainless Steel Wire Guard ....................................................

Standard Finishes:
• Aluminum – Corro-free™ epoxy powder coat
• Stainless steel – natural

Energy Savings:
• Less wattage used with compact fluorescent lamps compared to
equivalent incandescent lamps providing the same light output
1068

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Suffix
S826

Copyright© 2013 Eaton’s Crouse-Hinds Business

Cat. #
V2PC20
V2PC22
V2PC27
P55

1068-1069.qxp

12/16/2013

7:34 PM

Page 1069

CPMVF Champ-Pak™
Compact Fluorescent
Luminaires

Ordering Information
Temperature Performance Data
Dimensions & Weights

5L

Ordering Information:
Hub Size (In.)

Luminaire
Watts

Cat. #

/4 NPT
/4 NPT

52
64

CPMVF2W052
CPMVF2W064

/4 NPT

84

CPMVF2W084

3
3
3

STANDARD VOLTAGE BALLASTS

OPTIONAL BALLASTS

NEC/UL & CEC/CSA (cUL)

CEC/CSA (cUL)

120–277V 50–60Hz

347V 60Hz

125V DC

12V DC

24V DC

/UNV

/347

/125VDC

/012VDC

/024VDC

Voltage
Suffix

(Consult Eaton's Crouse-Hinds)

CPMVF Temperature Performance Data – Consult Eaton's Crouse-Hinds

Dimensions
In Inches:

5L

Net Weight:
Description
CPMVF Less Guard
P55 Guard

Lbs.
17 lbs.
0.5 lbs.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1069

1070-1071.qxp

5L

12/16/2013

7:42 PM

Page 1070

VMVF Series
Fluorescent Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II, Ex nR IIC

IEC Zone 2, Ex nR IIC
UL/CSA
IEC 60079-15

Champ® Luminaires
Applications:
VMVF Series Champ Luminaires are used:
• In refineries, chemical, petrochemical, and pharmaceutical plants,
wastewater treatment facilities
• In shipboard, drilling rigs, drilling platforms
• In flour and feed mills, grain elevators, sugar and cocoa plants
• In area/structure lighting, security lighting, parking areas

Features and Benefits:
Increased Productivity
• Instant-on luminaire eliminates flicker-free starting and increases
safety and productivity
Consistent Design
• Luminaire components are of the same materials as standard VMV
and DMV
• Popular components are available from stock; offers visual
consistency throughout installation
High Lumen Output
• Compact fluorescent light fixture provides higher lumen output
with increased color rendering index (CRI)
Reliable Performance in Any Environment
• Energy-efficient universal ballast suitable for 120-277V 50/60Hz minimum starting temperature of -18°C provides long lamp life and
lamp end-of-life protection
• UL marine rated, NEMA 4X/IP66 luminaire prevents water ingress
and is suitable for the most adverse outdoor environments

Certifications and Compliances:
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nR II, Ex nR IIC
• IEC:
IEC Zone 2, Ex nR IIC
• UL Standards:
UL844 Hazardous (Classified) Locations
UL1598 Luminaires, UL1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
IEC 60079-15

Ordering Information Example:

5L

VMV

F

2A

042

1. Series
VMV
DMV
2. Lamp/Function
F (Fluorescent)
FB (Fluorescent with Battery Back-up) (DMV only)
3. Mounting Style
Blank
No Cover
J
1 1/2” Stanchion 25º
P
1 1/2” Stanchion Straight
2A
3/4” Pendant
3A
1” Pendant
2C
3/4” Ceiling
3C
1” Ceiling
2HA
3/4” Offset Pendant (low wattage only)
2TW
3/4” Wall Mount
3TW
1” Wall Mount
25Q
3/4” Quad Mount
4. Wattage
042
42W F (VMVF)
084
84W F (DMVF/DMVFB)
5. Globe and Guard
GP
G24 Globe and P21 Guard (VMVF)
GP
G303 Globe and P33 Guard (DMVF)
6. Voltage
/UNV
120-277V 50/60Hz Fluorescent
/347
(For Canada)
7. Suffixes
S714
Furnished with Lamps
S806
Cover Furnished with Stainless Steel Insert
S826
Restricted Breathing (Cl. I, Div. 2 & Zone 2 Suitability, Cooler T-Numbers)
S826TB
Restricted Breathing Supplied with Terminal Block Connections (Certified for IEC Zone 2)
S858
Red Paint for Exterior
S890
Quick Clip
FA
Factory Assembled with Lamps Installed

1070

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

GP

Copyright© 2013 Eaton’s Crouse-Hinds Business

/UNV

S714

1070-1071.qxp

12/16/2013

7:42 PM

Page 1071

DMVF Series
Compact Fluorescent
Champ® Luminaires
Applications:
DMVF Series Champ Luminaires are used:
• In areas made hazardous by abnormal
conditions resulting in the presence of
flammable vapors or gases

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

5L

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP66

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III & Simultaneous
Presence (Class I, Division 2 and Class II)

• In areas made hazardous by the
presence of combustible dusts

Class I, Zone 2

• Where combustible dusts and flammable
vapors are present simultaneously

• IEC:

• In marine applications where water
spray and corrosive atmospheres are
considerations

• UL Standards:

• On installations where vibration and
rough usage are problematic

Zone 2 Ex nR IIC
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations

• Where a cool, efficient light source is
required

• CSA Standards:

• In areas that require lamps to reach full
illumination immediately

• IEC Standards:

• In refineries, chemical and petrochemical
facilities, grain processing, handling or
storage facilities, manufacturing plants,
wastewater treatment plants, sewage
treatment plants, oil terminals, food
processing facilities, breweries, and any
other manufacturing or processing
facility where safe, reliable, hazardous
area fluorescent or auxiliary lighting is
needed

C22.2 No. 137

Accessories:
Reflectors (to be used with globe)
Type
Cat. #

60079-15

Standard Materials:

Dome
30° Angle

• Ballast housings and mountings –
copper-free aluminum (less than 0.4
of 1%)

To be ordered separately.

• Exterior hardware and guards – stainless
steel
• Reflectors – Krydon® fiberglassreinforced polyester

Standard Features:
• Housings made of die-cast copper-free
aluminum (less than 0.4 of 1% copper)
for strength and resistance to corrosion

• Hubs are provided with an integral
conduit stop and bushing to help
prevent damage to field wiring during
installation
• Epoxy powder finish and stainless steel
external hardware for resistance to
corrosion
• Long-life gaskets which provide seals
between mounting module, housing, and
optical assembly
• Grounding wire for safety
• Cool operating design
• Optional stainless steel open bottom
guard permits direct access to the globe
for easy relamping
• Optional battery pack ballast for auxiliary
lighting

Standard Finishes:
• Aluminum – gray epoxy powder coat
• Krydon material – high reflectance white
• Stainless steel – natural

Energy Savings
• Less wattage used with compact
fluorescent lamps compared to
equivalent incandescent lamps providing
the same light output

Electrical Rating Ranges:
• Wattage: Two 26, 32, or 42 watt lamps
• 120–277V, 50–60Hz
• 347V, 60Hz
• 12, 24, and 125VDC

5L

• Mounting modules equipped with
integral hub set screws for vibration
resistance (ceiling, pendant, and quad
mounts)

• Globe – heat- and impact-resistant
internally fluted glass

RD739
RA739

Options:
Description
Suffix
Restricted Breathing Construction ................................................................................. S826
Class I, Division 2 & Zone 2 Suitability
Cooler Operating Temperatures (T-Numbers)
Certified for IEC Zone 2 (Suffix S826TB) ........................................................................S826TB
Furnished with
Terminal Block
Crimp Terminals
Factory assembled with lamps installed for additional labor savings ...........................
FA
Fused – to protect ballast against abnormal line conditions (not available on CSA
certified fixtures) (not suitable for marine applications) .................................................
S658
Lamps supplied with fixture...........................................................................................
S714
Top hat with stainless steel threaded insert to attach ballast housing..........................
S806
TEFLON® coating on globe for increased shatter protection.........................................
S808
Quick-Clip ....................................................................................................................... S890

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1071

1072-1073.qxp

5L

12/16/2013

7:34 PM

Page 1072

DMVF Series
Compact Fluorescent

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Champ® Luminaires

Mounting
Style
Pendant Mount

Hub
Luminaire
Size (In.) Watts
3

/4
1
/4
1
3
/4
1

52

3

64

/4
/4
3
/4

52
64
84

DMVF2HA052GP
DMVF2HA064GP
DMVF2HA084GP

/4
1
3
/4
1
3
/4
1

52

DMVF2C052GP
DMVF3C052GP
DMVF2C064GP
DMVF3C064GP
DMVF2C084GP
DMVF3C084GP

/4
1
3
/4
1
3
/4
1

52

Flexible Pendant
Mount

3

Ceiling Mount
Thru-Feed

3

Wall Mount
Thru-Feed

DMVF Series
Fluorescent
with G303 Globe
and P33 Guard
Cat. #
DMVF2A052GP
DMVF3A052GP
DMVF2A064GP
DMVF3A064GP
DMVF2A084GP
DMVF3A084GP

84

3

64
84

3

64
84

DMVF2TW052GP
DMVF3TW052GP
DMVF2TW064GP
DMVF3TW064GP
DMVF2TW084GP
DMVF3TW084GP

3
3

/4
/4
3
/4

52
64
84

DMVF25Q052GP
DMVF25Q064GP
DMVF25Q084GP

Stanchion Mount
25° Angle

11/2
11/2
11/2

52
64
84

DMVFJ052GP
DMVFJ064GP
DMVFJ084GP

Stanchion Mount
Straight

11/2
11/2
11/2

52
64
84

DMVFP052GP
DMVFP064GP
DMVFP084GP

5L

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/ 2° Angle

1.

Catalog numbers are basic numbers. Voltages must be specified.
STANDARD VOLTAGE BALLASTS
NEC/UL & CEC/CSA (cUL)
CEC/CSA (cUL)

Voltage
Suffix

1072

120–277V 50–60Hz
/UNV

www.crouse-hinds.com

US: 1-866-764-5454

347V 60Hz
/347

CAN: 1-800-265-0502

OPTIONAL BALLASTS
125V DC
/125VDC

12V DC
/012VDC

24V DC
/024VDC

Copyright© 2013 Eaton’s Crouse-Hinds Business

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP66

1072-1073.qxp

12/16/2013

7:34 PM

Page 1073

5L

DMVF Series – Ordering by Components

DMVF luminaires are available in components.
A complete
I.
II.
III.

luminaire consists of:
Champ Cover (Mounting Module)
DMVF Ballast Housing
Globe, Globe Guard, Globe Reflectors

I. Champ Cover (Mounting Module):
Type
Pendant Mount

Conduit

Cat. #

/4"
1

APM2
APM3

Flexible Pendant

3

/4"

HPM2

Ceiling

3

/4"
1

CM2
CM3

Wall

3

/4"
1

TWM2
TWM3

Stanchion - 25 Degree Angle

11/2"

JM5

Stanchion - Straight

11/2"

PM5

Quad-Mount

3

/4"

QM25

3

II. Ballast Housings:
Complete catalog number must have the voltage suffix (UNV shown) and any
options suffixes.
Lamp Type
Compact Fluorescent

Lamp Watts

Cat. #

2 (26W)
2 (32W)
2 (42W)

DMVF052/UNV
DMVF064/UNV
DMVF084/UNV

III. Globe, Guards and Reflectors:
Cat. #

Globe
Teflon Coated
Globe Guard
Globe Reflector-Dome
Globe Reflector-Angle

G303
G303S808
P33
RD739
RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

5L

Type

Copyright© 2013 Eaton’s Crouse-Hinds Business

1073

1074-1075.qxp

5L

12/16/2013

7:34 PM

Page 1074

DMVF Series
Compact Fluorescent

Family Tree

5L

Champ® Luminaires

*These plastic reflectors are for non-hazardous areas only (50-100W max).

1074

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1074-1075.qxp

12/16/2013

7:34 PM

Page 1075

DMVF Series
Compact Fluorescent

5L

Temperature Performance Data
Weights

Champ® Luminaires
Temperature Performance Data:
Lamp
Watts

Minimum
Operating
Temperature

Maximum
Ambient
Temp.

Fluorescent: DMVF

Class I
Non-restricted
Restricted
Breathing
Breathing
Div. 2

Class II

Simultaneous Presence
Non-restricted
Restricted
Breathing
Breathing

Zone 2 or
Div. 2

Division 1

Cl. I, Div. 2/Cl. II

Cl. I, Zone 2 or
Div. 2/Cl. II

Supply
Wire °C

52 Watt

–20°C (4°F)

40°C (104°F) T3

T6

T6

T3/T6

T6

60

64 Watt

–20°C (4°F)

40°C (104°F) T3

T6

T6

T3/T6

T6

60

84 Watt

–20°C (4°F)

40°C (104°F) T3

T6

T6

T3/T6

T6

60

Net Luminaire Weights:
Luminaire
Series

Luminaire
with Globe,
Guard (lbs.)

Lamp
Watts

181/4
Lbs.

DMVF
52, 64, 84
Type
Add for mounting modules:
Pendant
Flexible Pendant
Ceiling
Wall
Quad-Mount
Angle Stanchion
Straight Stanchion

11/4
11/2
23/4
41/2
31/2
31/2
41/2

Add for reflectors:
Dome
11/4
30° Angle
Deduct: 1 lb. for luminaire with P33 Guard

13/4

5L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1075

1076-1077.qxp

12/16/2013

5L

6:50 PM

Page 1076

DMVF Series
Compact Fluorescent

Photometric Data

Champ® Luminaires

Note: For 52 watt DMVF applications, use a .75 multiplier.
For complete 84W IES files, please log onto www.crouse-hinds.com and go
to Resources > Specification and Design Support > Photometric Files.

DMVF Photometric Data
Isofootcandle Chart:
Luminaire with globe and dome reflector

DMVF064GRD Dome Reflector

DMVF064GRD Dome Reflector
Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
Eff.
Ceil.

5L

Footcandle Values for
Isofootcandle Lines
Mtg.
Hgt.

A

B

C

D

E

8'
10'
12'
16'

4.00
2.56
1.78
1.00

2.00
1.28
0.89
0.50

1.00
0.64
0.44
0.25

0.50
0.32
0.22
0.13

0.25
0.16
0.11
0.06

Room Cavity Ratio
Wall

1

2

3

4

5

6

7

8

9

10

80*

50*
30*
10*

.741
.694
.652

.617
.548
.491

.524
.445
.382

.452
.370
.308

.396
.314
.254

.351
.271
.214

.314
.237
.183

.283
.210
.159

.258
.188
.140

.236
.169
.125

70*

50*
30*
10*

.722
.679
.640

.601
.537
.483

.510
.437
.378

.440
.364
.305

.386
.309
.252

.342
.267
.212

.307
.234
.182

.277
.207
.158

.252
.185
.139

.231
.167
.124

50*

50*
30*
10*

.686
.650
.617

.570
.516
.470

.484
.421
.369

.418
.351
.299

.367
.299
.247

.326
.259
.209

.293
.227
.180

.265
.202
.155

.242
.181
.138

.223
.163
.123

30*

50*
30*
10*

.653
.623
.596

.542
.497
.457

.460
.406
.361

.398
.340
.293

.350
.290
.243

.311
.251
.206

.280
.221
.177

.254
.197
.154

.233
.176
.136

.214
.160
.121

.50*
30*
10*
0*

.622
.598
.576
.557

.516
.478
.444
.424

.437
.392
.352
.332

.379
.329
.287
.267

.333
.271
.239
.220

.297
.244
.203
.184

.268
.215
.175
.157

.244
.192
.152
.136

.224
.172
.135
.119

.206
.156
.120
.105

10*
0*

*Percent Reflectance.

1076

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1076-1077.qxp

12/16/2013

6:50 PM

Page 1077

DMVF Series
Compact Fluorescent

Dimensions

5L

Champ® Luminaires
Dimensions
In Inches:

Pendant Mount

Quad-Mount

25° Angle Stanchion Mount

Wall Mount

5L

Ceiling Mount

Ceiling Mount – Top View

Straight Stanchion Mount

Luminaire with Globe, Guard, Reflectors

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1077

1078-1079.qxp

5L

12/16/2013

6:50 PM

Page 1078

N2MVF Series
Compact Fluorescent

Marine & Wet Locations
Cl. I, Div. 2, Groups A, B, C, D
3, 3R, 4, 4X; IP56
Cl. II, Groups F, G
Cl. III & Simultaneous Presence

Champ® Non-metallic Luminaires
Applications:
N2MVF Series Champ Luminaires are
used:
• In areas in which ignitable
concentrations of flammable gases or
vapors will be present due to abnormal,
unusual or accidental conditions
• In installations where moisture, dirt,
vibration, corrosion, or rough usage are
concerns
• Wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements are found
• Ideal for marine use; resists the harmful
effects of salt water
• Withstands the harshest of corrosive
environments
• To provide low wattage spot and
floodlighting
• For general area lighting
• In manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities, wastewater
and sewage treatment facilities, offshore,
dockside, and harbor installations as well
as other heavy industrial applications

5L

Features and Benefits:
• Housings and mounting modules made
of polyphenylene sulfide (PPS) for
strength and maximum resistance to
corrosion
• Pendant mounting module equipped
with integral hub set screws for vibration
resistance
• Hubs are provided with an integral
bushing to help prevent damage to field
wiring during installation and ground
connection for positive bonding
• Guard, hub inserts, stanchion elbow, and
hardware made of stainless steel for
maximum resistance to corrosion
• Grounding wire for safety
• Stainless steel open bottom guard
permits direct access to the globe for
easy relamping
• Hinged assembly allows the luminaire to
hang free during installation to permit the
use of both hands when wiring
• One external captive screw for ease of
installation
• Handle – hinge assembly doubles as a
handle for ease of installation, especially
when carrying up a ladder

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 2, Groups A, B C, D
Class II, Class III & Simultaneous
Presence (Class I, Division 2 and II)
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137

Standard Materials:
• Housing, mounting modules –
polyphenylene sulfide (PPS)
• Guard, hub inserts, stanchion elbow,
hardware – stainless steel
• Globe – heat- and impact-resistant,
internally fluted glass
• Gaskets – silicone rubber

Electrical Ratings:
• Wattages: Two 26 or 32 watt
lamps
• 120-277V, 50-60Hz
• 347V, 60Hz
• 12, 24, and 125 VDC

Average Luminaire Weight
Description
Body, mounting module, globe,
guard, and reflector

Fluorescent Energy Savings
• Less wattage used with compact
fluorescent lamps compared to
equivalent incandescent lamps providing
the same light output

Mounting
Style

Hub
Size in.

Lamp
Watts

3

/4
1
/4
1

52

3

64

/4
1
3
/4
1

52

Ceiling Mount
Thru-Feed
Stanchion Mount
25° Angle

11/2
11/2

52
64

Pendant Mount

3

Voltage
Suffix

120–277V 50–60Hz
/UNV

Minimum
Operating
Temperature

52 & 64 Watt –18°C (0°F)
US: 1-866-764-5454

With G303
Globe and
P33 Guard
Cat. #
N2MVF2A052GP
N2MVF3A052GP
N2MVF2A064GP
N2MVF3A064GP
N2MVF2C052GP
N2MVF3C052GP
N2MVF2C064GP
N2MVF3C064GP

64

Maximum
Ambient
Temp.

Fluorescent: N2MVF

www.crouse-hinds.com

30

N2MVFJ052GP
N2MVFJ064GP
Optional Ballasts

CEC/CSA (cUL)
347V 60Hz
/347

125V DC
/125VDC

12V DC
/012VDC

24V DC
/024VDC

Temperature Performance Data:
Lamp
Watts

1078

Lbs.

Ordering Information:

Standard Voltage Ballasts
NEC/UL & CEC/CSA (cUL)

Additional Features:

Options:
Description
Suffix
Wall-Mount Arm
For converting a ceiling-mount
luminaire to a wall mount .......... N2MV-WM1
Factory Assembled
For a factory assembled
luminaire with lamps installed ...........
FA
Fusing
To protect ballast against
abnormal line conditions (not
suitable for marine applications) ...... S658
Furnished with Lamps ....................... S714
Teflon Coated Globe
Provides additional protection
against shattered glass
fragments when subject to
thermal shock, etc. ........................... S808

CAN: 1-800-265-0502

40°C (104°F)

Class I
Non-restricted
Breathing

Class II

Division 2

Division 1

T2D

T4

Copyright© 2013 Eaton’s Crouse-Hinds Business

Supply
Wire °C
85

1078-1079.qxp

12/16/2013

6:50 PM

Page 1079

5L

N2MVF Series Ordering by Components

N2MVF Luminaires are available in components.
A complete luminaire consists of:
I.
N2MV Cover (Mounting Module)
II.
N2MV Ballast Housing
III.
Globe, Refractors, Guards, Reflectors

I. N2MV Cover (Mounting Module):
Type
Pendant

Conduit

Cat. #

3

/4"
1"

N2APM2
N2APM3

Ceiling

3

/4"
1"

N2CM2
N2CM3

Wall (Use wall bracket
accessory with Ceiling Cover)
Stanchion – 25 Degree Angle

3

/4"
1"

N2MV WM1 and N2CM2
N2MV WM1 and N2CM3

11/2"

N2JM5

II. Ballast Housings:
Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes.
Lamp
Lamp
Type
Watts
Compact Fluorescent

Cat. #

2 (26W)

N2MVF052/UNV

2 (32W)

N2MVF064/UNV

III. Globe, Guards, and Reflectors:
Cat. #

Globe

G303

Globe Teflon Coated

G303S808

Globe Guard

P33

Reflector Dome

RD739

Reflector Angle

RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

5L

Type

1079

1080-1081.qxp

5L

12/16/2013

6:50 PM

Page 1080

N2MVF Series
Compact Fluorescent

Family Tree

Champ® Non-metallic Luminaires
A complete luminaire consists of a cover mount, a ballast housing and a globe, with or without guard,
refractor or reflector.

5L

All Components are suitable for
use in ordinary locations, Class I,
Div. 2 and wet locations.

1080

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1080-1081.qxp

12/16/2013

6:50 PM

Page 1081

N2MVF Series
Compact Fluorescent

5L

Dimensions
Weights

Champ® Non-metallic Luminaires
Dimensions
In Inches:

Ceiling Mount – Top View

25° Angle Stanchion Mount

Ceiling Mount

5L

Pendant Mount

Net Luminaire Weights:
Luminaire
Series

Lamp
Watts

Luminaire with
Mounting Module,
Globe, Guard &
Refractor (lbs.)

N2MVF052
N2MVF064

52
64

30
30

Accessories:
Reflectors (to be used with globe)
Type
Cat. #
Dome
30° Angle

RD739 (RD79)
RA739 (RA79)

To be ordered separately.

Wall Arm Mount

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1081

1082-1083.qxp

12/16/2013

5L

6:51 PM

Page 1082

Photometric Data

N2MVF Series
Compact Fluorescent
Champ® Non-metallic Luminaires

N2MVF Photometric Data
Isofootcandle Chart:
Luminaire with globe and dome reflector

N2MVF064GRD Dome Reflector

Note: For 52 watt N2MVF applications, use a .75 multiplier.

5L

Footcandle Values for Isofootcandle Lines
Mounting
Height

A

B

C

D

E

8'
10'
12'
16'

4.00
2.56
1.78
1.00

2.00
1.28
0.89
0.50

1.00
0.64
0.44
0.25

0.50
0.32
0.22
0.13

0.25
0.16
0.11
0.06

N2MVF064GRD Dome Reflector
Coefficients of Utilization
Effective Floor Cavity Reflectance 20%
Room Cavity Ratio
Eff.
Ceil.

Wall

1

2

3

4

5

6

7

8

9

10

80*

50*
30*
10*

.741
.694
.652

.617
.548
.491

.524
.445
.382

.452
.370
.308

.396
.314
.254

.351
.271
.214

.314
.237
.183

.283
.210
.159

.258
.188
.140

.236
.169
.125

70*

50*
30*
10*

.722
.679
.640

.601
.537
.483

.510
.437
.378

.440
.364
.305

.386
.309
.252

.342
.267
.212

.307
.234
.182

.277
.207
.158

.252
.185
.139

.231
.167
.124

50*

50*
30*
10*

.686
.650
.617

.570
.516
.470

.484
.421
.369

.418
.351
.299

.367
.299
.247

.326
.259
.209

.293
.227
.180

.265
.202
.155

.242
.181
.138

.223
.163
.123

30*

50*
30*
10*

.653
.623
.596

.542
.497
.457

.460
.406
.361

.398
.340
.293

.350
.290
.243

.311
.251
.206

.280
.221
.177

.254
.197
.154

.233
.176
.136

.214
.160
.121

10*

50*
30*
10*

.622
.598
.576

.516
.478
.444

.437
.392
.352

.379
.329
.287

.333
.271
.239

.297
.244
.203

.268
.215
.175

.244
.192
.152

.224
.172
.135

.206
.156
.120

0*

0*

.557

.424

.332

.267

.220

.184

.157

.136

.119

.105

*Percent Reflectance.

1082

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1082-1083.qxp

12/16/2013

6:51 PM

Page 1083

EVLPF Series
Compact Fluorescent

Cl. I, Div. 1, Groups B
(GB Suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(GB Suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G
Class III, Simultaneous Presence

Low Profile Hazard•Gard®
Luminaires

Marine & Wet
Locations
3, 3R, 4, 4X; IP66

5L

Applications:
Eaton's Crouse-Hinds Low Profile
Hazard•Gard® luminaires are used in:
• Areas where flammable or explosive
vapors or gases are present
• Hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
• Petroleum refineries, chemical,
petrochemical and pharmaceutical
plants, oil terminals, gas plants and other
heavy process industry facilities
• Waste treatment facilities
• Drilling platforms and other coastal and
offshore hazardous areas

Features and Benefits:

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 1, Groups B
(GB suffix), C, D
Class I, Zone 1, Groups IIB + H2
(GB Suffix), IIB, IIA
Class II, Class III & Simultaneous
Presence
(Class I and Class II)
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards
C22.2 No. 137

Standard Materials:

Standard Finishes:
• Copper-free aluminum – Corro-free™
powdered epoxy
• Krydon – white
• Stainless steel guard

Ratings (Electrical/Size):
Sources/Wattage:
• 52W (two 26W lamps) & 64W (two 32W
lamps)
• 120–277V, 50–60Hz
• 347V, 60Hz
• 12, 24, 125 VDC
Conduit Entries:
• 3/4", 1" NPT – Pendant, Wall Bracket,
Ceiling
• 11/4" NPT – Stanchion

• Mounting modules, cover, ballast
housing, globe holder – copper-free
aluminum
• Globe – heat- and impact-resistant glass
• Exterior hardware – stainless steel
• Reflectors (dome & angle) – Krydon®
fiberglass-reinforced polyester

Options:
Description
Suffix
Group B suitability ..........................................................................................................
GB
Fused (not suitable for marine applications) .................................................................... S658
Factory assembled with lamps ........................................................................................
FA

Accessories:
Description

Cat. #

Dome reflector ................................................................................................................ RD739
Angle reflector ................................................................................................................ RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1083

5L

• Small, compact size
• Two start Acme threaded construction
• Lightweight copper-free aluminum
housing with powdered epoxy finish
• All exterior hardware is corrosionresistant stainless steel
• Four mounting arrangements - pendant,
ceiling, wall bracket, and stanchion
• Wide range of light sources and
wattages
• Marine and NEMA 4X construction
• Integral ballast
• High power factor (90%+) ballasts
• Uses same mounting modules as the
standard Hazard•Gard®
• Internally fluted glass globes
• Krydon® construction dome and angle
reflectors – won't rust, corrode, dent,
chip, or peel
• Now available in components – luminaire
body, mounting module, guard,
reflectors
• Three wire construction is standard on
fluorescent emergency lighting
• Perfect where low mounting restrictions
are a concern
• Easier assembly, installation and
maintenance
• Superior corrosion resistance
• Suit any lighting layout
• Meet specific lighting needs
• Outdoor, hose down, marine, and
corrosive environments suitable
• Lowest installed cost
• Allows more luminaires per circuit
• Easy retrofitting when the EVLPF is
the preferred choice
• Reduces glare and distributes light
evenly – ideal for adverse environments
typical of industrial facilities
• Easily stocked for quick ship
requirements
• For energy conservation, luminaires can
be switched off without affecting the
emergency operation feature

1084-1085.qxp

5L

12/16/2013

6:51 PM

Page 1084

EVLPF Series
Compact Fluorescent

Cl. I, Div. 1, Groups B
(GB Suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(GB Suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G
Class III, Simultaneous Presence

Low Profile Hazard•Gard®
Luminaires

Pendant

Wall Bracket*

Ceiling*

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Luminaire Body
Less Mounting
Module & Guard

Stanchion

Hub
With Guard
With Guard
With Guard
With Guard
Watt Size (In.) Cat. #
Cat. #
Cat. #
Cat. #
Cat. #
Fluorescent—High Power Factor Ballast (Min. P.F. 90%)
3
EVLPFA02521 EVLPFBX02521 EVLPFCX02521
EVLPF0520
/4
EVLPFA03521 EVLPFBX03521 EVLPFCX03521
52W 1
EVLPFJ04521
11/4
/4
1
11/4
3

64W

EVLPFA02641 EVLPFBX02641
EVLPFA03641 EVLPFBX03641

EVLPFCX02641
EVLPFCX03641

EVLPF0640
EVLPFJ04641

Pendant Mount
Pendant
Wall Bracket*
Hub
Without Guard
Without Guard
Watt Size (In.) Cat. #
Cat. #
Fluorescent—High Power Factor Ballast (Min. P.F. 90%)
3
EVLPFA02520
EVLPFBX02520
/4
EVLPFA03520
EVLPFBX03520
52W 1
11/4
/4
1
11/4
3

64W

EVLPFA02640
EVLPFA03640

EVLPFBX02640
EVLPFBX03640

Ceiling*
Without Guard
Cat. #
EVLPFCX02520
EVLPFCX03520

EVLPFJ04520
EVLPFCX02640
EVLPFCX03640
EVLPFJ04640

Complete Catalog Number as follows:
*Wall Bracket Mount

1.

Voltages - Add suffix as follows:
Standard Voltage Ballasts - 60Hz

Optional Ballasts

NEC/UL & CEC/CSA (cUL)

CEC/CSA (cUL)

120–277V 50–60Hz
/UNV

347V 60 Hz
/347

125V DC
/125VDC

12V DC
/012VDC

5L

Voltage
Suffix

*Ceiling Mount

Stanchion Mount

*Ceiling and bracket mounts have 4 hubs: 3 are plugged.

1084

www.crouse-hinds.com

US: 1-866-764-5454

Stanchion
Without Guard
Cat. #

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

24V DC
/024VDC

1084-1085.qxp

12/16/2013

6:51 PM

Page 1085

EVLPF Series
Ordering By Components

5L

EVLP Luminaires are available in components.
A complete light fixture consists of:
I.
Mounting Module
II.
Fixture Body
III.
Guard, Dome Reflector, Angle Reflector, or Exit Sign

Mounting Modules:
Type
Pendant
Ceiling & Wall Box
Wall Bracket Arm
Stanchion
Guards
Fluorescent

Conduit

Cat. #

3

/4"
1

EVMP2
EVMP3

3

/4"
1

EV22
EV33

Use EV22 or EV33 box with EV87
11/4"

EV87
EVMJ4
EV512

Reflectors
Dome
Angle

RD739
RA739

Pendant

Ceiling

Stanchion

Ceiling

Wall Bracket

EVMP2
EVMP3

EV22
EV33

EVMJ4

EV22
EV33

EV87 & EV22 or EV33

5L

Fixture Body
EVLPF0520/UNV
EVLPF0521/UNV
EVLPF0640/UNV
EVLPF0641/UNV

Guards

Dome Reflector

Angle Reflector

EV512

RD739

RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1085

1086-1087.qxp

12/16/2013

5L

6:51 PM

Page 1086

Dimensions and Weights

EVLPF Series
Compact Fluorescent
Low Profile Hazard•Gard®
Luminaires

Temperature Performance Data:

Fluorescent Fixtures
Maximum Ambient
Fluorescent

52W & 64W

Class I, Group B
(w/GB suffix)
Groups C, D
Class I, Zone I
40°C

Class II, Groups E, F, G
Class III
Simultaneous
Presence
40°C

Supply Wire °C

Minimum
Operating
Temperature

T6

T6

75°C

–18°C

Dimensions

5L

In Inches:

Fluorescent

A

B

15.69

14.69

C

D

18.25

18.46

E

F

22.34

21.30

Weights:
Item

Lbs.

Fluorescent
(EVLPF)

31.5

Add Mounting Modules:
Pendant
Ceiling
Bracket
Stanchion

1
2
4.5
2.5

Add For Reflectors & Exit Sign:
RA739
RD739
DMVF–EXD
Deduct .5 lb for Wire Guard

1086

www.crouse-hinds.com

US: 1-866-764-5454

1
1
5

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1086-1087.qxp

12/16/2013

6:52 PM

Page 1087

EVLPF Series
Compact Fluorescent

5L

Photometric Data

Low Profile Hazard•Gard® Luminaires
Luminaire with Globe and Guard
EVLPFA03641 Two 32 W Compact Fluorescent

5L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1087

1088-1089.qxp

5L

12/16/2013

6:52 PM

Page 1088

EVLPF Series
Compact Fluorescent

Photometric Data

Low Profile Hazard•Gard® Luminaires
Luminaire with Globe and Dome (Less Guard)
EVLPFA03640RD Lamp: Two 32 W Compact Fluorescent

Luminaire with Globe and 30° Angle Reflector (Less Guard)

5L

EVLPFA03640RA Lamp: Two 32 W Compact Fluorescent

1088

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1088-1089.qxp

12/16/2013

6:52 PM

Page 1089

FVS Series
Long Twin Tube
Fluorescent Luminaires

5L

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Cl. I, Div. 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III, Simultaneous Presence

Applications:

Size Ranges:

FVS Compact Fluorescent Luminaires are
used:
• Where low mounting heights or limited
mounting room exists
• For task oriented lighting
• Where a cool, efficient light source is
required
• In areas that require lamps to reach full
illumination immediately
• In industrial and chemical processing
• In pulp and paper facilities
• In waste or sewage treatment facilities
• In non-hazardous commercial and
industrial areas
• In food and pharmaceutical plants where
a non-glass lens is required
• Where fluorescent lighting has been
preferred, but unavailable due to limited
space and practicality

• All luminaires are 24"
L x 12" W x 3.12" H
• Conduit entrances are 3/4"

Features:

Standard Materials:
• Corrosion-resistant die cast copper-free
aluminum housing
• Shatter-resistant nylon lens
• Polycarbonate lens (suffix -S813)
• Silicone rubber gasket
• Extruded aluminum hinges and closure
hardware with stainless steel pivots

• UNV (120–277V), 50–60 Hz
• 347V, 60 Hz
• Two 40 watt long twin tube lamps

Accessories
Certifications and
Compliances:
• NEC and CEC:
Class I, Division 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
(Suffix S813)
Class II, Division 2, Groups F, G
Class III & Simultaneous Presence (Cl. I
and Cl. II)
Note: Aiming Limitations
Cl. II, Cl. III & Simultaneous Presence
Aim down to Horizontal
Cannot aim up
• UL Standards
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards
C22.2 No. 137

FVS Trunnion Mount Kit (FVS-K5)
• Permits vertical mounting of luminaire on
a beam when used with a standard
beam clamp
• Can be mounted directly to a wall or
ceiling
• Can be pole mounted when used in
conjunction with a SFA6 slipfitter
adapter (ordered separately)
• Constructed from copper-free aluminum
• Supplied with a CGB cord connector

FVS with Trunnion Arm and Slipfitter

5L

• Compact, lightweight, low profile design
is ideal for confined areas and tight
corners
• Reaches full illumination immediately
and delivers light output equivalent to
fixtures twice its size
• Fast-Latch™ closure provides quick and
easy access for relamping and
maintenance – no tools necessary
• Silicone sealing gasket provides
exceptional watertight and dust-tight
bond, providing excellent performance in
wet and corrosive environments
• Power disconnect switch (Eaton's
Crouse-Hinds ESWP) automatically cuts
power to the lamps and ballast when the
lens is opened
• Shatter-resistant polymeric lens (0.125
thick) provides environmental and
corrosion protection
• Available in UNV (120-277) and 347
50/60 Hz voltages
• Two lamp fixture, uses single-ended 40
watt lamps
• Multiple mounting capability
• Energy saving electronic ballast is
standard

Electrical Ratings:

Options:
Description
Suffix
• Fused to protect ballast under abnormal line conditions (not available on CSA
certified fixtures) (not suitable for marine applications) ................................................ S658
• Fixture supplied with two F40BX/SPX35 lamps ........................................................... S714
• Corro-free™ epoxy finish inside and out ...................................................................... S753
• Tamperproof ..................................................................... Consult Eaton's Crouse-Hinds

Temperature Performance Data:
Ambient
Style Temp °C
All
40°C
All
55°C

Class I,
Div. 2

Simultaneous
Class II
Presence
See Aiming Limitations

Supply
Wire

Minimum
Operating
Temperature

T3C
T3C

T6
—

75°C
75°C

–18°C (0°F)
–18°C (0°F)

T3C/T6
—

Luminaire Weight:
Without Lamps
Type
Standard 2 lamp FVS

lbs.
12.0

Standard Finishes:
• Epoxy powder coated housing
• Anodized hinges and closure hardware
• Highly specular aluminum reflector

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1089

1090-1091.qxp

12/16/2013

5L

6:52 PM

Page 1090

Cl. I, Div. 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III, Simultaneous Presence

FVS Series
Long Twin Tube
Fluorescent Luminaires

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Luminaire includes all necessary provisions for these installations:

Ceiling Mount

Pendant Mount

Corner Mount

Horizontal Wall Mount

FVS compact fluorescent (2 lamp luminaire):
Voltage

Wattage/
Lamp

Hub
Size (4)

Cat. #

Cat. # with
Class II,
Div. 1 Suitability

120–277 (50 or 60 Hz)
347 (50 or 60 Hz)

40
40

3

/4"
3
/4"

FVS20/UNV
FVS23

FVS20/UNV S813
FVS23 S813

Accessories (Ordered
Separately):
Description

Cat. #

• Trunnion arm kit
• Slipfitter adapter to be used
with trunnion arm

FVS K5

Dimensions:
FVS with Trunnion Arm: 261/4" x 13.5" W x 3.12" H

5L

Top View

Side View

FVS With Lens Open

1090

www.crouse-hinds.com

US: 1-866-764-5454

FVS Showing
Mounting Strap Positioning

CAN: 1-800-265-0502

Vertical Wall Mount

Copyright© 2013 Eaton’s Crouse-Hinds Business

SFA6

1090-1091.qxp

12/16/2013

6:52 PM

Page 1091

Photometric Data

FVS Series
Long Twin Tube

5L

Fluorescent Luminaires
Luminaire: FVS
Lamp: (2) F40BX/SPX35/RS single-ended fluorescent.
Total initial lumens: 6300

Coefficients of Utilization

Isofootcandle Chart

Effective Floor Cavity Reflectance 20%
Room Cavity Ratio
Wall

1

2

3

4

5

6

7

8

9

10

50*
30*
10*

.621
.594
.569

.538
.495
.459

.469
.419
.378

.414
.359
.317

.367
.312
.270

.329
.273
.234

.297
.242
.204

.269
.216
.180

.246
.195
.160

.225
.176
.144

70*

50*
30*
10*

.606
.582
.560

.526
.487
.453

.459
.412
.374

.405
.354
.314

.360
.308
.268

.323
.270
.232

.291
.240
.203

.265
.214
.179

.242
.193
.160

.222
.175
.143

50*

50*
30*
10*

.580
.560
.541

.503
.470
.442

.441
.400
.367

.389
.345
.310

.347
.300
.265

.311
.265
.230

.281
.235
.201

.256
.210
.178

.234
.190
.159

.216
.172
.143

30*

50*
30*
10*

.555
.539
.524

.483
.455
.431

.423
.389
.360

.374
.336
.305

.334
.293
.262

.301
.259
.227

.272
.230
.199

.248
.207
.176

.227
.187
.157

.210
.170
.142

10*

50*
30*
10*

.533
.520
.507

.464
.441
.421

.407
.378
.353

.361
.327
.300

.322
.287
.258

.290
.254
.225

.264
.226
.197

.241
.203
.175

.221
.184
.156

.204
.167
.141

0*

0*

.494

.407

.339

.286

.245

.212

.185

.163

.145

.130

Footcandle Values for
Isofootcandle Lines
Mtg.
Hgt.
8'
10'
12'
16'

A

B

C

D

E

5.00
3.20
2.22
1.25

3.00
1.92
1.33
0.75

1.00
0.64
0.44
0.25

0.50
0.32
0.22
0.13

0.20
0.13
0.09
0.05

Spacing to Mounting Height
Ratio
Along lamp axis (A-A)
Across lamp axis (B-B)

0.6
1.1

*Percent Reflectance.
†FVS suitable for Class II, Div. 1, Groups E, F, G when ordered with suffix S813.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1091

5L

Eff.
Ceil.
80*

1092-1093.qxp

12/16/2013

5L

6:52 PM

Page 1092

EVFT Illuminator™
Long Twin Tube
Fluorescent Luminaires

Cl. I, Div. 1, Groups B & C (suffix GB), D
Cl. I, Zone 1, Group IIB + H2 (suffix GB), IIA
Cl. II, Div. 1, Groups E, F, G
Cl. III Simultaneous Presence

Paint Spray
Marine & Wet Locations
3, 3R, 4, 4X; IP66

Applications:
Illuminator™ Compact Fluorescent
Luminaires are used:
• In areas made hazardous by the
presence of flammable gases and
vapors, combustible dusts, or easily
ignitable fibers and flyings
• In areas where combustible dusts and
flammable gases are present
simultaneously
• In applications involving low mounting
heights, restricted mounting space, or
where luminaire weight must be
minimized
• In areas where corrosion, vibration,
moisture, dirt, and rough usage are a
problem
• In refineries, chemical and petrochemical
facilities, grain processing, handling and
storage facilities, manufacturing plants,
wastewater treatment facilities, airline
and mass transit maintenance areas,
paint spray facilities, breweries,
pharmaceutical plants, and other areas
where safe, reliable hazardous area
lighting is required in a compact, cool
operating and efficient light source

5L

Features:
• Efficient fluorescent light source in 78
and 156 watts
• Adjustable right and left asymmetrical
reflectors provide excellent light
"aimability" – ideal for task oriented
lighting
• Compact, lightweight, and low profile
design allows easy installation and broad
industrial application
• Cast copper-free aluminum with epoxy
powder finish (less than 0.4 of 1%
copper) provides excellent resistance to
corrosion
• Versatile luminaire housing provides
choice of pendant, wall, or ceiling mount
• Suitable for paint spray areas; linear light
source provides excellent color rendition
for paint spray tasks; easy to install,
disposable, clear tube wrap helps
maintain maximum light output during
painting operations
• Threaded construction, factory wiring
and sealing help minimize installation
time; no external seals are required
• Fixtures are used with two or four long
twin tube single-ended fluorescent lamps
• Optional stainless steel guard provides
extra protection for lamps and lamp tube
• Optional clear polycarbonate tube
provides 360° protection for lamps and
lamp tube; ideal for maintenance pit and
pharmaceutical applications
• Grounding connection for safety
• Available for 120 or 277 VAC
• Standard electronic ballast

1092

www.crouse-hinds.com

US: 1-866-764-5454

4 lamp with stainless steel wire guard and adjustable reflectors

Options:

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 1, Group D
Class I, Division 1, Group B, C, D (suffix GB)
Class I, Zone 1, Group IIA
Class I, Zone 1, Group IIB + H2 (suffix GB)
Class II, Groups E, F, G
Class III
Simultaneous Presence (Cl. I and Cl. II)
Paint Spray
Note: Aiming Limitations
Cl. II, Cl. III & Simultaneous Presence
- Aim Down to Horizontal
- Cannot aim up
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137

Description
Suffix
Fused to protect circuit under
abnormal conditions (not available
on CSA certified luminaires) (not
suitable for marine applications) ....... S658
Luminaire supplied with lamps.......... S714
Class I, Groups B and C suitability
pendant mount only .......................... GB

Electrical Ratings:
• Input voltage – 120 or 277 VAC, 60 Hz
• Wattages – 78 – 2 lamp luminaire
156 – 4 lamp luminaire

Fixture Weights
Illuminator
lbs.
2 lamp with guard ............................. 19.5
4 lamp with guards ........................... 36.5
RAL1, RAR1 reflectors (each) ........... 3.0
Deduct for luminaire without P51 Guard:
1 lb. for 2 lamp
2 lbs. for 4 lamp

Standard Materials:
• Center and ballast housings, end caps –
copper-free aluminum
• Lamp tube – heat-resistant glass
• Guards – stainless steel or clear
polycarbonate material
• Reflectors – aluminum

Standard Finishes:
• Center and ballast housings, end caps,
guards – natural
• Reflectors – white epoxy finish

Temperature Performance Data:
Luminaire
Type
2 and 4
Lamp

Minimum
Operating
Temp.

Maximum
Ambient
Temp.

Class I, Division 1 & Zone 1
Class II, Division 1
Supply
Simultaneous Presence
Wire

10°C
(50°F)

40°C
(104°F)

T4A

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

75°C

1092-1093.qxp

12/16/2013

6:52 PM

Page 1093

Cl. I, Div. 1, Groups B & C (Suffix B), D
Cl. I, Zone 1, Groups IIB + H2
(Suffix B), IIA
Cl. II, Div. 1, Groups E, F, G
Cl. III, Simultaneous Presence

EVFT Illuminator™
Long Twin Tube
Fluorescent Luminaires

Paint Spray
Marine & Wet Locations
3, 3R, 4, 4X; IP66

5L

Ordering Information:

Style

Luminaire
Voltage

Without
Guard

With P51
Guard†

Without
Guard

With P51
Guard†

/4
/4

120
277

EVFT22320
EVFT22370

EVFT22321
EVFT22371

EVFT22320 GB
EVFT22370 GB

EVFT22321 GB
EVFT22371 GB

/4
/4

120
277

EVFT24320
EVFT24370

EVFT24321
EVFT24371

EVFT24320 GB
EVFT24370 GB

EVFT24321 GB
EVFT24371 GB

3
3

4 Lamp

Class I
Cat. # with Group B, C & D Suitability

Hub
Size (In.)
3

2 Lamp

Class I
Cat. # with Group D Suitability

3

†P51 supplied in separate carton.

Accessories:
Type

Aiming Limitations:
Cat. #

•
•
•
•

Stainless steel wire guard..........
P51
Reflector right hand ................... RAR1
Reflector left hand...................... RAL1
Polycarbonate tube
(not used with optional stainless
steel wire guard) ........................
PG1
• Disposable clear wrap – 5 pack
(for use with optional
polycarbonate tube) ................... PTW1

In Class II, Class III and Simultaneous Presence locations
• Aim down to horizontal
• To prevent dust from accumulating in reflector, do not aim up
• The Illuminator lighting fixtures are designed for operation with the lamp in a horizontal to
base down position

Dimensions:

RAL1 RAR1
Reflectors (as viewed facing
front of fixture)
Note: For 4 lamp unit, you must order
one of each refractor, if required.
Illuminator two lamp luminaire with reflector

5L

Stainless steel guard

Polycarbonate tube and retaining plate

Illuminator four lamp luminaire with reflectors
Disposable polyester tube wrap
(used over optional polycarbonate tube)

‡For GB suffix (Groups B & C) this dimension is 34.0". For CSA certified fixtures this dimension is 359/ 16".
■For GB suffix (Groups B & C) this dimension is 8.38".

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1093

1094-1095.qxp

5L

12/16/2013

6:53 PM

Page 1094

Photometric Data

EVFT Illuminator™
Long Twin Tube
Fluorescent Luminaires

Illuminator two lamp luminaire with reflector (without guard)
Lamps: Two 39 watt BIAX* fluorescent

Footcandle Values for
Isofootcandle Lines
Mtg. Ht.
(ft.)
8
10
12
16

A

B

C

D

E

F

10.0
6.4
4.4
2.5

5.00
3.20
2.22
1.25

2.00
1.28
0.89
0.50

1.00
0.64
0.44
0.25

0.50
0.32
0.22
0.13

0.25
0.16
0.11
0.06

Illuminator four lamp luminaire with reflectors (without guards)

5L

Lamps: Four 39 watt BIAX* fluorescent

Footcandle Values for
Isofootcandle Lines
Mtg. Ht.
(ft.)
10
12
16
20

*BIAX is a trademark of the General Electric Company.

1094

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

A

B

C

D

E

F

8.0
5.6
3.1
2.0

4.00
2.78
1.56
1.00

2.00
1.39
0.78
0.50

1.00
0.69
0.39
0.25

0.50
0.35
0.20
0.13

0.20
0.14
0.08
0.05

1094-1095.qxp

12/16/2013

6:53 PM

Page 1095

EVFT Illuminator™
Long Twin Tube

5L

Coefficients of Utilization

Fluorescent Luminaires
Luminaire: EVFT 22320 with RAR1 Reflector
Lamps: Two F39BX/SPX35/RS
Lumen Rating: 2900 Lumens/Lamp
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall
0
1

2

3

4

Room Cavity Ratio
5
6

7

8

9

10

80

70
50
30
10

.51
.51
.51
.51

.46
.44
.41
.40

.41
.38
.35
.32

.38
.33
.29
.26

.34
.29
.25
.22

.31
.25
.21
.18

.29
.23
.19
.16

.26
.20
.16
.14

.24
.18
.14
.12

.22
.16
.13
.10

.21
.15
.11
.09

70

70
50
30
10

.49
.49
.49
.49

.45
.43
.41
.39

.40
.37
.34
.31

.37
.32
.29
.26

.33
.28
.25
.22

.30
.25
.21
.18

.28
.22
.18
.16

.26
.20
.16
.14

.24
.18
.14
.12

.22
.16
.12
.10

.20
.14
.11
.09

50

50
30
10

.47
.47
.47

.41
.39
.38

.35
.33
.31

.31
.28
.26

.27
.24
.22

.24
.21
.18

.21
.18
.16

.19
.16
.13

.17
.14
.12

.15
.12
.10

.14
.11
.09

30

50
30
10

.45
.45
.45

.39
.38
.37

.34
.32
.30

.30
.27
.25

.26
.24
.21

.23
.20
.18

.21
.18
.15

.19
.16
.13

.17
.14
.11

.15
.12
.10

.14
.11
.09

10

50
30
10

.43
.43
.43

.37
.36
.35

.33
.31
.29

.29
.27
.25

.25
.23
.21

.22
.20
.18

.20
.17
.15

.18
.15
.13

.16
.13
.11

.14
.12
.10

.13
.10
.08

0

0

.43

.35

.28

.24

.20

.17

.14

.12

.10

.09

.08

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Luminaire: EVFT 24320 with RAR1 & RAL1 Reflectors
Lamps: Four F39BX/SPX35/RS
Lumen Rating: 2900 Lumens/Lamp

2

3

4

Room Cavity Ratio
5
6

7

8

9

10

80

70
50
30
10

48
.48
.48
.48

.44
.42
.40
.39

.40
.37
.34
.31

.37
.32
.29
.26

.33
.29
.25
.22

.30
.25
.21
.19

.28
.22
.19
.16

.26
.20
.16
.14

.24
.18
.14
.12

.22
.16
.13
.10

.20
.15
.11
.09

70

70
50
30
10

.47
.47
.47
.47

.43
.41
.40
.38

.39
.36
.33
.31

.36
.32
.29
.26

.33
.28
.25
.22

.29
.25
.21
.18

.27
.22
.18
.16

.25
.20
.16
.14

.23
.18
.14
.12

.21
.16
.12
.10

.20
.14
.11
.09

50

50
30
10

.45
.45
.45

.39
.38
.37

.34
.32
.30

.30
.28
.26

.27
.24
.22

.24
.21
.18

.21
.18
.16

.19
.16
.14

.17
.14
.12

.15
.12
.10

.14
.11
.09

30

50
30
10

.43
.43
.43

.38
.37
.36

.33
.31
.30

.29
.27
.25

.26
.23
.21

.23
.20
.18

.20
.18
.16

.18
.16
.13

.17
.14
.12

.15
.12
.10

.14
.11
.09

10

50
30
10

.41
.41
.41

.36
.35
.35

.32
.30
.29

.28
.26
.25

.25
.23
.21

.22
.20
.18

.20
.17
.15

.18
.15
.13

.16
.13
.12

.14
.12
.10

.13
.11
.09

0

0

.41

.34

.28

.24

.20

.17

.15

.13

.11

.09

.08

5L

Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall
0
1

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1095

1096-1097.qxp

5L

12/16/2013

6:53 PM

Page 1096

Higher Ambient Suitability: 55°C
Cold Weather Start (32W T8 Lamps)
Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC

NFL Series
Fluorescent
Luminaires

Wet Locations
3, 3R, 4, 4X

Applications:
The NFL Light Luminaires are used:
• In hazardous locations where dust,
dirt, combustible vapors, smoke, fumes,
moisture, corrosive, and wet conditions
are present
• Where lamps may be broken due to
physical abuse or movable equipment,
such as in manufacturing areas or
warehouses
• Where cleanliness and sanitation are
prime factors such as in dairies,
canneries, food processing plants,
bottling plants, and laboratories
• In dock areas for protection against salt
spray
• In areas where low mounting height and
the even light distribution associated
with a line type light source are required

5L

Key Features:
• UL, cUL Listed for Class I, Division 2,
Groups A, B, C, D areas with ambient
suitability of 40°C (104°F) and 55°C
(131°F) ambient suitability
• NEMA 4X with Myers Hubs and threaded
metal plug (furnished)
• Non-metallic construction enclosure is
corrosion-resistant
• Continuous form-in-place gasket ensures
dust-tight, moisture-tight, and wet
locations integrity
• Molded-in-place mounting studs –
eliminate the need of bracket gaskets
• Standard construction includes:
S.S. mounting brackets
Electronic ballast
Cold weather ballast (4' F32 T8)
• S.S. mounting bracket combination
ceiling and chain
• S.S. mounting brackets provide superior
corrosion resistance
• Electronic ballast for energy efficiency
• Cold Weather Ballast (4' F32 T8)
• Two 1/2" conduit Myers Hubs for end and
feed through wiring simplify installation
and wiring
• Full metal fixture interior provides
improved photometrics as well as access
to and concealment of ballast and wiring
• Provisions (drill mark) on 4 ft. unit to field
drill for pendant mounting for application
and installation flexibility

www.crouse-hinds.com

Sources/Wattage: luminaires are for
use with the following lamps
• NFL2140
one 40 W long twin tube
• NFL4232
two 32W T8 lamps
• NFL4240
two 34W "F40 Style" T12 lamps
Voltages
• 120V 60Hz
• 120 – 277V, 50 – 60 Hz
• 347V 60 Hz
Conduit Entries
• Two 1/2" inch Myers hubs,
one on each end

Celecon™ is a trade name of Hoechst Celanese.

Standard Finishes:
• Fiberglass housing – white
• Acrylic plastic lens – crepe pattern

Options:
Description
Suffix
• Fused (not suitable for
marine applications) ............
S658
• Factory assembled with
lamps installed ....................
FA
• Battery back-up
emergency ballast† (NFL
2140 and NFL 4232 only)....
S799*
• Increased impact-resistant
lens (acrylic crepe pattern).. DR1295046*
• Stainless steel latches ........
S863*
• Tamperproof latches...........
S861*
†For non-hazardous locations.
*UNV voltages: 120, 208, 230, 240, 277, 50–60 Hz.

Temperature Performance Data:
Ambient temperature range suitability:
Two lamp, 32W T8, 4 ft luminaire
All others
Supply wire

US: 1-866-764-5454

°C
-18°C to 55°C
0°C to 55°C
75°C min.

Ordering Information:
Size/# of Lamp(s)

NFL2140/UNV

Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
UL Listed 844
cUL
Wet locations
4X

1096

Ratings (Electrical/Size):

Luminaire
Cat. #

Certifications and
Compliances:
•
•
•
•
•
•

Standard Materials:
• Housing – non-metallic, one piece
fiberglass-reinforced polyester
• Latches – Celcon™ acetal plastic
• Lens – acrylic plastic
• Gaskets – seamless thermoset
polyurethane
• Mounting Bracket – stainless steel

NFL2140/347

2 ft/ 1-lamp

Wattage/ Lamp type

Voltage/Hz

40W T5 compact
single ended

120 / 60
120–277/50–60
347 / 60

NFL4232/UNV

4 ft/2-lamp

32W T8
rapid start

120 / 60
120–277/50–60

NFL4240/120
NFL4240/277
NFL4240/347

4ft/2-lamp

34W T12
"F40 Style"
rapid start

120 / 60
277 / 60
347 / 60

N2FL4232/UNV
N2FL4232/347

4ft/2-lamp

32W T8
rapid start

347 / 60

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1096-1097.qxp

12/16/2013

6:53 PM

Page 1097

NFL Series Fluorescent
Luminaires

5L

Photometric Data

Luminaire: All NFL Luminaires
Candlepower Distribution Curve
(in Candelas)

Zonal Lumens

Candelas
Angle

Along

Across

Zone

Lumens

0°

1049

1049

0–30

862

10°

1034

1056

0–40

1462

20°

978

1071

0–60

2778

30°

866

1075

0–90

4130

40°

762

1027

0–180

4499

50°

606

939

60°

416

838

70°

228

723

80°

92

549

90°

17

363

100°

19

243

110°

10

131

120°

5

46

130°

4

20

140°

4

9

150°

4

3

• Candlepower Distribution Curve (in
candelas) and Zonal Lumens – These
values are for all NFL series luminaires,
adjusted by conversion factors
(multipliers) below.

160°

4

0

Example:

170°

0

0

180°

0

0

• Candlepower at 20° across for NFL4232
using two (2) F32T/35K lamps (5700
lumen total) is 1071 candelas.

Photometric data, developed using two (2)
F32T8/35K 2850 lumen lamps, represents
the performance of all NFL series
luminaires.
• Coefficient of Utilization – These values
are for all NFL series luminaires (Do not
use multipliers).

• Candlepower at 20° across for NFL2140
using one (1) T5 compact lamp (3100
lumen total) is 1071 x .55 = 589
candelas.
Lamp
Qty

NFL2140
NFL4232
NFL4240

2
2
1

Watts

Type
(Lumens ea.)

Conversion
Factor
(multipliers)

32
34
40

F32T8/35K (2850)
F40T12/RS (2650)
T5 Compact (3150)

1.0
0.93
0.55

5L

Luminaire
Series

Coefficient of Utilization: For all NFL Series Light Luminaires
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceiling
Wall

Room Cavity Ratio
1
2
3

4

5

6

7

8

9

10

80

70
50
30
10

.83
.78
.74
.71

.75
.67
.61
.56

.68
.59
.52
.46

.62
.52
.44
.39

.56
.45
.38
.32

.51
.40
.33
.28

.47
.36
.29
.24

.44
.32
.25
.20

.40
.29
.22
.17

.37
.26
.20
.15

70

70
50
30
10

.80
.76
.72
.69

.72
.65
.60
.55

.65
.57
.51
.46

.59
.50
.43
.38

.54
.44
.37
.32

.49
.39
.32
.27

.46
.35
.28
.23

.42
.31
.25
.20

.39
.28
.22
.17

.36
.26
.19
.15

50

50
30
10

.71
.68
.66

.61
.57
.53

.54
.48
.44

.47
.42
.37

.42
.35
.31

.37
.31
.26

.33
.27
.23

.30
.24
.20

.27
.21
.17

.24
.19
.15

30

50
30
10

.67
.65
.62

.58
.54
.51

.51
.46
.42

.45
.40
.36

.39
.34
.30

.35
.30
.26

.32
.26
.22

.28
.23
.19

.25
.20
.16

.23
.18
.14

10

50
30
10

.63
.61
.59

.54
.51
.48

.48
.44
.41

.42
.38
.35

.37
.33
.29

.33
.29
.25

.30
.25
.22

.27
.22
.18

.24
.19
.16

.22
.17
.14

0

0

.57

.46

.39

.33

.27

.23

.20

.17

.14

.12

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1097

1098-1099.qxp

12/16/2013

5L

6:54 PM

Page 1098

NFL Series Fluorescent
Luminaires

Dimensions and Weights

Dimensions:
Net Luminaire Weights
Luminaire Series

Weight (lbs.)

NFL2140
NFL4232

9.1
14.3

NFL4240

14.3

5L

Temperature Performance Data:
Lamp
Type

Supply Wire
Temp. °C

Class I, Div. 2
Temp. Rating

Class II
Temp. Rating

Simultaneous
Presence
Class I, Div. 2

Cat. No.

Watts

Ambient
Temp. °C

NFL4232
NFL4232

32
32

40
55

T8
T8

60
75

T6
T5

-

-

NFL4240

34

40

T12

60

T6

-

-

NFL4240

34

55

T12

75

T5

-

-

NFL2140

40

40

T12

60

T6

-

-

NFL2140

40

55

T12

75

T5

-

-

1098

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1098-1099.qxp

12/16/2013

6:54 PM

Page 1099

eLLK Series™ Fluorescent
Non-metallic Luminaires

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
(Canada)
Cl. II, Div. 2, Groups F, G (US)
Cl. III, Simultaneous Presence

Wet Locations
3, 3R, 4, 4X; IP66
ATEX Certified

5L

Applications:
• eLLK Fixtures are used in hazardous
areas where moisture or corrosion may
be a problem
• Offshore oil platforms, pharmaceuticals,
plants, oil refineries
• Where battery back-up is critical
• In non-hazardous and industrial
locations

Features:

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 2, Groups B, C, D
Class I, Zone 1, Group IIC
Class II, Division 1, Groups E, F, G
(Canada)
Class II, Division 2, Groups F, G (US)
Class III, Simultaneous Presence
(Cl. I and Cl. II)
• UL Standards:
1598 Luminaires
• CSA Standards:
E79 Series
• ATEX Directive 94/9/EC:
Ex II 2 G Ex de IIC T4
Ex II 2 D Ex tD A21 IP66 T80°C
• EC-Type Examination Certificate:
BVS 09 ATEX E034
• GOST-R, GOST-K

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

5L

• IEC: Zone 1 and 2 areas
• NEC/CEC: Zone 1, Division 2 areas
Electronic Ballast:
• Operates at voltage range of 110–254
VAC ± 10%, 50–60 Hz
• Wide ambient temperature range
suitability -25°C to +55°C (eLLK92),
-25°C to +50°C (eLLK92NIB)
• Lamps operate independently – one
lamp failure will not affect remaining
lamp operation
• Standard bi-pin lamps – most common
lamp used in office enviroments; energyefficient and cost effective
• Interlocked switch – automatically cuts
power to both lamps and ballast when
the lens is opened
• Removable lens – hinged on both sides
for easy installation and maintenance
• Dual entries– extra large wire well
eliminates need for separate junction
boxes (own with cable gland and
conduit hub)
• Corrosion-resistant construction - nonmetallic body, gasketed lenses, and lens
locking system for an IP66, NEMA 4X
rating
Battery Back-up Features:
• Operates one lamp for 11/2 hours should
power go out
• Microprocessor monitors the charging
functions of the battery
• LEDs provide visual indication of battery
life

Copyright© 2013 Eaton’s Crouse-Hinds Business

1099

1100-1101.qxp

12/16/2013

5L

6:54 PM

Page 1100

eLLK Series™ Fluorescent
Non-metallic Luminaires

Ordering Information:
Cat. #

Description

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 1, Group IIC
Cl. II, Div. 1, Groups E, F, G
(Canada)
Cl. II, Div. 2, Groups F, G (US)
Cl. III, Simultaneous Presence

Length &
Lamp Type

Lamp Watt 2 Lamp

Rated
Voltage

Rated
Current

Wet Locations
3, 3R, 4, 4X; IP66
ATEX Certified

Conduit Hub
Size*

Comments

NEC (NOT ATEX CERTIFIED)
1 2265 875 309

eLLK 92 2217
/U240 1/6 2 NPT 3/4"

2-foot T8 NEC

17W

120V-240V,
0.38-0.18A
50-60 Hz, 120-230 DC

2 ea. - 3/4"
Myers hub

No throughfeed

1 2265 875 310

eLLK 92 2217
/U240 1/6 2 NPT 1/2"

2-foot T8 NEC

17W

120V-240V,
0.38-0.18A
50-60 Hz, 120-230 DC

2 ea. - 1/2"
Myers hub

No throughfeed

1 2265 875 311

eLLK 92 2217
/U240 2/6 2 NPT 3/4"

2-foot T8 NEC

17W

120V-240V,
0.38-0.18A
50-60 Hz, 120-230 DC

4 ea. - 3/4"
Myers hub

Throughfeed

1 2266 875 309

eLLK 92 4232
/U240 1/6 2 NPT 3/4"

4-foot T8 NEC

32W

120V-240V,
0.7-0.34A
50-60 Hz, 120-230 DC

2 ea. - 3/4"
Myers hub

No throughfeed

1 2266 875 310

eLLK 92 4232
/U240 1/6 2 NPT 1/2"

4-foot T8 NEC

32W

120V-240V,
0.7-0.34A
50-60 Hz, 120-230 DC

2 ea. - 1/2"
Myers hub

No throughfeed

1 2266 875 311

eLLK 92 4232
/U240 2/6 2 NPT 3/4"

4-foot T8 NEC

32W

120V-240V,
0.7-0.34A
50-60 Hz, 120-230 DC

4 ea. - 3/4"
Myers hub

Throughfeed

1 2260 879 333

eLLK 92NIB 2217
/U120 2/6 2 NPT 3/4"

2-foot T8 NEC

17W
120V, 50-60 Hz,
(with battery) 120-230 DC

0.38A

4 ea. - 3/4"
Myers hub

Throughfeed

1 2260 879 311

eLLK 92NIB 2217
/U240 2/6 2 NPT 3/4"

2-foot T8 NEC

17W
240V, 50-60 Hz,
(with battery) 120-230 DC

0.18A

4 ea. - 3/4"
Myers hub

Throughfeed

4 ea. - 3/4"
Myers hub
4 ea. - 3/4"
Myers hub

Throughfeed
Throughfeed

1 2261 879 333
1 2261 879 311

eLLK 92NIB 4232
/U120 2/6 2 NPT 3/4"
eLLK 92NIB 4232
/U240 2/6 2 NPT 3/4"

4-foot T8 NEC
4-foot T8 NEC

32W
120V, 50-60 Hz,
(with battery) 120-230 DC
32W
240V, 50-60 Hz,
(with battery) 120-230 DC

0.7A
0.34A

5L

IEC (ATEX CERTIFIED)
1 2265 875 109

eLLK 92 018/18
1/6-1 M

2-foot T8 IEC

18W

120V-240V, 50-60 Hz 0.38-0.18A

2 ea. 20mm metric

No throughfeed

1 2265 875 111

eLLK 92 018/18
2/6-2 M

2-foot T8 IEC

18W

120V-240V, 50-60 Hz 0.38-0.18A

4 ea. 20mm metric

Throughfeed

1 2266 875 109

eLLK 92 036/36
1/6-1 M

4-foot T8 IEC

36W

120V-240V, 50-60 Hz 0.7-0.34A

2 ea. 20mm metric

No throughfeed

1 2266 875 111

eLLK 92 036/36
2/6-2 M

4-foot T8 IEC

36W

120V-240V, 50-60 Hz 0.7-0.34A

4 ea. 20mm metric

Throughfeed

1 2260 879 109

eLLK 92 018
/18NIB 1/6-1 M

2-foot T8 IEC

18W
240V, 50-60 Hz
(with battery)

0.18A

2 ea. 20mm metric

No throughfeed

1 2260 879 111

eLLK 92 018
/18NIB 2/6-2 M

2-foot T8 IEC

18W
240V, 50-60 Hz
(with battery)

0.18A

4 ea. 20mm metric

Throughfeed

1 2260 879 409

eLLK 92 018
/18NIB 1/6-1 M

2-foot T8 IEC

18W
120V, 50-60 Hz
(with battery)

0.38A

2 ea. 20mm metric

No throughfeed

1 2260 879 411

eLLK 92 018
/18NIB 2/6-2 M

2-foot T8 IEC

18W
120V, 50-60 Hz
(with battery)

0.38A

4 ea. 20mm metric

Throughfeed

1 2261 879 109

eLLK 92 036
/36NIB 1/6-1 M

4-foot T8 IEC

36W
240V, 50-60 Hz
(with battery)

0.18A

2 ea. 20mm metric

No throughfeed

1 2261 879 111

eLLK 92 036
/36NIB 2/6-2 M

4-foot T8 IEC

36W
240V, 50-60 Hz
(with battery)

0.18A

4 ea. 20mm metric

Throughfeed

1 2261 879 409

eLLK 92 036
/36NIB 1/6-1 M

4-foot T8 IEC

36W
120V, 50-60 Hz
(with battery)

0.7A

2 ea. 20mm metric

No throughfeed

1 2261 879 411

eLLK 92 036
/36NIB 2/6-2 M

4-foot T8 IEC

36W
120V, 50-60 Hz
(with battery)

0.7A

4 ea. 20mm metric

Throughfeed

*2 hubs provided. May be connected through-feed or tandam. Cable glands ordered separately for

/ " (remove hubs) or M 25 openings (remove hubs).

3

4

Lamp Selection:
Weights:

NEC LAMP
Type
Phillips
GE
Osram/Sylvania

17W
F17T8/Tl841
F17T8/SPX41
F017/841

32W
F32T8/TL841
F32T8/SPX41
FO32/841

18W
3 2475 900 081

36W
3 2475 900 002

IEC LAMP
Type
CEAG
1100

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Watts
17W and
17W and
32W and
32W and

Weight
18W
18W (with battery)
36W
36W (with battery)

Copyright© 2013 Eaton’s Crouse-Hinds Business

4.6 Kg. (10 lb.)
10 Kg. (22 lb.)
6.7 Kg. (14 lb.)
12 Kg. (26 lb.)

1100-1101.qxp

12/16/2013

6:54 PM

Page 1101

eLLK Series™
Fluorescent Non-metallic
Luminaires
Accessories:

Accessories
Dimensions

5L

Dimensions
In Millimeters:

Eyebolt A2

Standard Luminaire with Back-up

Hexagon Screw S4

Ceiling Mounting Bracket D92

Type

Corrosion
Protection

Pipe
DIN

Outer Ø
D (mm)

Quantity per
Luminaire
Cat. #

Eyebolt A2

Galvanized

—

—

2

2 2480 002 000

Hexagon Screw S4

Stainless Steel

—

—

2

2 2480 054 000

Ceiling Mounting
Bracket D92

Stainless Steel

—

—

2

2 2480 092 000

Pipe Clamp

R12
R14
R22
R32

11/4"
11/4"
11/2"
2"

38–42
38–42
47–51
56–60

2
2
2
2

2
2
2
2

Hexagon Key SW13
—
eLLK 92

—

—

—

3 2485 000 005

Wall Bracket W27

—

42.4

1

2 2483 027 000

Hot Galvanized
CrNi
Hot Galvanized
Hot Galvanized

Hot Galvanized

2480
2480
2480
2480

462
464
472
482

000
000
000
000

5L

Pipe Clamp

Wall Bracket W27

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1101

1102-1103.qxp

12/16/2013

6:54 PM

Page 1102

eLLK Series™
Fluorescent Non-metallic
Luminaires

5L

Photometric Data

Photometric data developed
using two (2) F32T8 3350
lumen lamps.
For the 17W eLLK, use a
0.45 multiplier.

Coefficient of Utilization

5L

Effective Floor Cavity Reflectance 20%
Room Cavity Ratio
Eff. Ceil. Wall
Work
1
2
3
80*
70*
20*
41
49
55
50*
20*
30
38
44
30*
20*
23
30
36
10*
20*
18
25
30

4

5

6

7

8

9

61
50
43
37

65
55
48
42

70
62
55
50

74
67
61
56

77
71
65
61

80
75
70
66

70*

70*
50*
30*
10*

20*
20*
20*
20*

40
29
22
18

47
37
30
24

53
42
35
30

58
49
42
36

62
54
47
42

68
60
54
49

71
65
59
54

74
68
64
59

77
72
68
64

50*

50*
30*
10*

20*
20*
20*

27
21
17

35
28
24

40
34
29

46
40
35

50
45
40

56
51
47

61
56
52

64
60
57

68
64
61

30*

50*
30*
10*

20*
20*
20*

26
20
17

38
27
23

37
32
28

43
38
34

47
43
39

58
49
45

57
53
50

60
57
54

64
61
58

10*

50*
30*
10*

20*
20*
20*

24
20
16

31
26
22

35
31
27

41
36
33

45
41
37

50
46
43

54
51
48

57
54
52

60
68
55

0*

0*

20*

14

20

25

31

35

41

46

49

53

*Percent Reflectance.

1102

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1102-1103.qxp

12/16/2013

6:54 PM

Page 1103

CI. I, Div. 2, Groups A, B, C, D
CI. I, Zone 2, AEx nA II
CI. II, Div. 2, Groups F, G
Enclosure Type 4X

nLLK Series Non-metallic
Fluorescent Luminaires

Wet Locations
UL and cUL Listed
ATEX Certified

5L

Eaton's Crouse-Hinds SpecOne™ nLLK Series Fluorescent
Luminaire is an ideal source of general illumination indoors or out, in
ordinary or hazardous environments. Its heavy duty, non-metallic
construction stands up to tough physical and environmental
demands, making it an excellent choice where dust, dirt, gas, vapor,
smoke, fumes, moisture, corrosive and wet conditions are present.
As with all SpecOne products, the nLLK Luminaire meets the
standards and codes of regulating agencies throughout the world,
which simplifies product specifying for multi-national users.

Applications:

Certifications and
Compliances:
• NEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA II
Class II, Division 2, Groups F, G
Wet Locations
UL Listed
• CEC:
Class I, Zone 2, Ex nA II
Class I, Division 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
cUL Listed (certified by UL)
• Enclosure:
Type 4X
IP65
• UL Standards:
844 Hazardous (Zones Classified)
Locations
1598 Luminaires
• CSA Standards:
C22.2 No. 9
CAN/CSA–E79-15

Standard Materials:
• One-piece housing – fiberglassreinforced polyester
• Lens – polycarbonate
• Gasket – silicone

Standard Finishes:
• Fiberglass housing – natural (white)
• Lens – natural (clear)

Ratings (Electrical/Size):
Sources/Wattages
• Two (2) 17W or two (2) 32W linear
fluorescent
Voltages
• 120–277 V, 50–60 Hz
• 347 V, 60 Hz — consult factory
Hub Size
• Four 25 mm entries, two on each end,
three plugged
• Two Myers STM2 25 mm to 3/ 4" NPT
adapter hubs provided standard for
through-feed or tandem wiring

ATEX
• ATEX Directive 94/9/EC

Ex II 3G Ex nA de IIC T4
Ex II 3G Ex nA de mb IIC T4
• Type of Protection
Ex II 3D Ex tD A22 IP66 T80°C
• EC-Type Examination Certificate BVS 09 ATEX E147

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1103

5L

nLLK Series Luminaires are used:
In indoor or outdoor, ordinary or
hazardous areas
Where a heavy duty, non-metallic
luminaire is required to hold up to tough
physical and environmental demands
including corrosives, water, dust, and
extreme temperatures
• Manufacturing plants
• Heavy industrial facilities
• Industrial process facilities
• Refineries
• Chemical
• Petrochemical
• Pharmaceutical
• Wastewater and sewage treatment
plants
In areas where low mounting height,
immediate full illumination, and the even
light distribution associated with a
line type light source are required
• Loading docks
• Tunnels
• Stairways
Where wet location or Type 4X
protection is required
• Dock areas
• Production platforms
In hose down areas where cleanliness
and sanitation are prime factors
• Dairies
• Canneries
• Food processing plants
• Bottling plants
• Laboratories

1104-1105.qxp

12/16/2013

6:55 PM

Page 1104

nLLK Series Non-metallic
Fluorescent Luminaires

5L

CI. I, Div. 2, Groups A, B, C, D
CI. I, Zone 2, AEx nA II
CI. II, Div. 2, Groups F, G
Enclosure Type 4X

Wet Locations
UL and cUL Listed

IP65, Type 4X heavy duty construction
• Non-metallic body, gasketed lens and unique labyrinth lens
locking system
• Dust-tight, water-tight and moisture-tight
• Corrosion and impact-resistant
• Ideal for outdoor applications
Electronic ballast
• Lower ambient temperatures suitability to -18°C
• High-power factor ballast (+90%) allows for more luminaires per
circuit
Standard T8 bi-pin lamps
• Most common lamp used; energy-efficient and cost-effective
Removable lens
• Hinged on both sides for easy installation and maintenance
Easy wiring and installation
• Four 25 mm entries; two Myers™ 3/4" NPT adapter hubs supplied
standard
• Suitable for through-feed or tandem applications
• Extra large wire well eliminates need for separate junction boxes
Worldwide suitability
• NEC/CEC: Class I, Zone 2 and Division 2 areas
• IEC/CENELEC certified luminaires available (consult factory)

Ordering Information:
Cat. #

Description

Length &
Lamp Type

Lamp
Watt - 2
Lamp

Rated Voltage

Rated
Current Conduit Hub Size

Comments

2-foot T8
2-foot T8
4-foot T8
4-foot T8

17W
17W
32W
32W

120V-277V, 60 Hz
347V, 60 Hz
120V-277V, 60 Hz
347V, 60 Hz

0.16A
0.16A
0.31A
0.31A

2 ea. - 3/4" Myers hub
2 ea. - 3/4" Myers hub
2 ea. - 3/4" Myers hub
2 ea. - 3/4" Myers hub

Through-feed
Through-feed
Through-feed
Through-feed

2-foot T8
2-foot T8
4-foot T8
4-foot T8

18W
18W
36W
36W

220V-240V, 50-60 Hz
220V-240V, 50-60 Hz
220V-240V, 50-60 Hz
220V-240V, 50-60 Hz

0.16A
0.16A
0.31A
0.31A

2 ea. - 25mm metric
2 ea. - 20mm metric
2 ea. - 25mm metric
2 ea. - 20mm metric

Through-feed
Through-feed
Through-feed
Through-feed

NEC (NOT ATEX CERTIFIED)
1 3465 217 021
1 3465 217 347
1 3465 232 021
1 3465 232 347

nLLK 98 2217 /UNV
nLLK 98 2217 /347 2/5 2 NPT 3/4" M UL
nLLK 98 4232 /UNV
nLLK 98 4232 /347 2/5 2 NPT 3/4" M UL

5L

IEC (ATEX CERTIFIED)
1 3465 218 011
1 3465 218 021
1 3465 236 011
1 3465 236 021

nLLK 08 018/18
nLLK 08 018/18
nLLK 08 036/36
nLLK 08 036/36

Accessories:
Description

Cat. #

SW13 hexagon key (for maintenance and lamp replacement)
Myers™ 25mm to 3/4" NPT adapter hub

3 2485 000 005
STM 2

Type

Corrosion
Protection

Pipe
DIN

Outer Ø
D (mm)

Quantity per
Luminaire

Eyebolt A2

Galvanized

—

—

2

2 2480 002 000

Hexagon Screw S4

Stainless Steel

—

—

2

2 2480 054 000

Ceiling Mounting Bracket D92

Stainless Steel

—

—

2

2 2480 092 000

Pipe Clamp

R12
R14
R22
R32

11/4"
11/4"
11/2"
2"

38–42
38–42
47–51
56–60

2
2
2
2

2
2
2
2

Hexagon Key SW13 eLLK 92

—

—

—

—

3 2485 000 005

Wall Bracket W27

Hot Galvanized

—

42.4

1

2 2483 027 000

1104

www.crouse-hinds.com

Hot Galvanized
CrNi
Hot Galvanized
Hot Galvanized

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Cat. #

2480
2480
2480
2480

462
464
472
482

000
000
000
000

1104-1105.qxp

12/16/2013

6:55 PM

Page 1105

nLLK Series Non-metallic
Fluorescent Luminaires

CI. I, Div. 2, Groups A, B, C, D
CI. I, Zone 2, AEx nA II
CI. II, Div. 2, Groups F, G
Enclosure Type 4X

Wet Locations
UL and cUL Listed

5L

Photometric Data:

Accessories:

Eyebolt A2

Temperature Performance:
Supply Wire
Temp.°C
60
60

Hexagon Screw S4

5L

Minimum Starting Temperature: -18°C
Class I, Div. 2
Class II, Div. 1 (CEC)
Watts
Ambient (Class I, Zone 2) Class II, Div. 2 (NEC)
Two 17W T8 lamps
40°C
T4
T6
Two 32W T8 lamps
40°C
T4
T6

Maintenance and Relamping:
(eLLK Series Div. 1/Zone 1 luminaire is shown. Maintenance procedures are the same for the nLLK.)
1.One quarter turn with the SW13
hexagon key or a 5/16" (M8) Allen hex
head wrench releases multiple locking
points.
2.Lamps can be stored in open lens,
freeing up hands for easy relamping.
3.Replace the bi-pin lamp lock with one
quarter turn of the wrench for an IP65,
Type 4X seal.

Ceiling Mounting Bracket D92

Dimensions (mm) and Weight:
Weight: 8.8 lbs. (4.0 kg.)—18W 13.2 lbs. (6.0 kg.)—36W

Pipe Clamp

Wall Bracket W27

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1105

1106-1107.qxp

12/16/2013

5L

6:55 PM

Page 1106

CI. I, Div. 2, Groups A, B, C, D
CI. I, Zone 2, Group IIC
CI. II, Div. 1, Groups F, G
CI. III & Simultaneous Presence

FVN Series
Fluorescent Luminaires

Wet Locations
NEMA 3, 3R

Applications:
FVN Luminaires are ideal for use:
• In areas made hazardous by the abnormal conditions resulting in
the presence of flammable vapors or gases and combustible dusts
as defined by the National Electrical Code®
• Where broken lamps would damage machinery or processes, or
harm people working in the area
• In areas where stringent sanitation requirements exist

Features:
• One-piece seamless sheet steel housing with welded end caps
keeps dirt, dust and moisture away from ballast and lamps; easy
to clean
• A silicone rubber gasket provides a dust-tight seal between the
lens/frame assembly and housing
• Lens/frame assembly is hinged and wireway cover is held by
safety chain for ease of lamp replacement and maintenance
• Polyester powder coat finish provides high reflectance and
corrosion resistance for long life and dependable service
• Two 1/ 2" NPT pendant hubs and two 1/2" NPT thru-feed end hubs
are standard
• Electronic ballast is standard on 32 and 54 watt luminaires
(/UNV only)
FVN Fluorescent Luminaires with T5 HO lamps offer:
• High lumen output per watt – provides energy savings versus other
higher wattage fluorescent luminaires with similar lumen output
• Longer lamp life and good lumen maintenance – reduced
maintenance and lamp replacement costs

•
•
•
•
•
•
•

Luminaire housing – 20-gauge seamless sheet steel
Lens/frame assembly – stainless steel
Glass – 3/ 16" tempered
Suspension flanges – seamless sheet steel
Gaskets – silicone
Lampholders – white thermoset plastic
Clamps – stainless steel

Standard Finishes:
• Reflector housings – corrosion-resistant white polyester
powder coat
• Lens/frame – natural

Dimensions
In Inches:
40”

Certifications and Compliances:

5L

Standard Materials:

8 1/2”

• NEC and CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, Group IIC
Class II, Division 1, Groups F, G
Class III
Simultaneous Presence (Cl. I and Cl. II)
• UL Standards:
844 Hazardous (Classified) Areas
1598 Luminaires
• CSA Standards:
C22.2 No. 137

53 1/4”

7 1/4”

5 3/4”

15”

Ordering Information (Lamps not supplied):
Lamp
Watts

Line
Voltage/Hertz

Lamp
Type

32
32
40
40
40
60
60
60
60

120–277/50–60
347 / 60
120 / 50–60
277 / 60
347 / 60
120 / 60
277 / 60
347 / 60
220 / 50

T8
T8
T12
T12
T12
T12HO
T12HO
T12HO
T12HO

Hub Size

2-Lamp Cat. #

3-Lamp Cat. #

/2
1
/2
1
/2
1
/2
1
/2
1
/2
1
/2
1
/2
1
/2

FVN4232TG/UNV
FVN4232TG/347
FVN4240TG/120
FVN4240TG/277
FVN4240TG/347
FVN4260TG/120
FVN4260TG/277
FVN4260TG/347
FVN4260TG/200 50

FVN4332TG/UNV
FVN4332TG/347
FVN4340TG/120
FVN4340TG/277
FVN4340TG/347
—
—
—
—

FVN4254TG/UNV
FVN4254TG/347

—
—

1

NPT
NPT
NPT
NPT
NPT
NPT
NPT
NPT
NPT

FVN Fluorescent Luminaires with T5 HO Lamps (Lamps not supplied)
1
54
120–277/50–60
T5HO
/2 NPT
1
54
347 / 60
T5HO
/2 NPT

1106

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1106-1107.qxp

12/16/2013

6:55 PM

Page 1107

FVN Series
Fluorescent Luminaires

CI. I, Div. 2, Groups A, B, C, D
CI. I, Zone 2, Group IIC
CI. II, Div. 1, Groups F, G
CI. III & Simultaneous Presence

5L

Wet Locations
NEMA 3, 3R

Options:
The following special options are available from the factory by adding suffix to luminaire Cat. No.:
Description
• Low temperature electromagnetic ballast, 40W rated 0°F (-18°C), 60W rated -20°F (-29°C).............................................................
• 45° angle brackets (field installed)........................................................................................................................................................
• Adjustable angle brackets (field installed)............................................................................................................................................
• Angle bars for chain suspension (field installed)..................................................................................................................................
• Individually fused ballast (internal)........................................................................................................................................................
• Emergency lighting battery unit (Class I, Division 2 only). Also available for use with T5 lamps. Supplied with charging indicator
light and instructions for use with a remote push-to-test station........................................................................................................

Suffix
BY
AG
KH
CX
FB
S799*

*If push-to-test operator installed in the luminaire is required, consult factory.

Temperature Performance Data:
(Based on 40°C ambient)
Cl. I, Div. 2 & Zone 2
Lamp
32W
40W
54W
60W

2-Lamp
T5
T5
T3C
T4

Class II

3-Lamp
T5
T5
—
—

2-Lamp
T6
T6
T6
T6

Simultaneous Presence
3-Lamp

T6
T6
—
—

2-Lamp
T4
T4
T3C/T6
T4

3-Lamp
T4
T4
—
—

Supply
Wire
60°C
60°C
75°C
90°C

Photometric Data:
Luminaire with two 54W High Output T5 Linear Fluorescent Lamps
FVN4254

5L

FVN .ies photometric files for use with our Luxicon® Lighting Layout Software are available from our website.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1107

1108-1109.qxp

12/16/2013

5L

6:55 PM

Page 1108

Photometric Data

FVN Series
Fluorescent Luminaires

Luminaire: FVN with 2-40W lamps
(tempered lens)
Lamp:
Zonal Degrees:
Zonal Lumens:
Total Bare Lamp Lumens:

2–40/T-12
0–30
1182
6300

Luminaire: FVN with 3–40W lamps
(tempered lens)

0–40 0–60 0–90
1971 3555 4284

Lamp:
Zonal Degrees:
Zonal Lumens:
Total Bare Lamp Lumens:

0–40 0–60 0–90
2834 5099 6079

All data provided is for 2-lamp
40W RS cool white luminaires
with tempered glass. Use 1.37
multiplier for 2-lamp 60W
luminaires with tempered glass.
Use .92 multiplier for 2-lamp
32W luminaires with tempered
glass.

All data provided is for 2-lamp
40W RS cool white luminaires
with tempered glass. Use 1.37
multiplier for 2-lamp 60W
luminaires with tempered glass.
Use .92 multiplier for 2-lamp
32W luminaires with tempered
glass.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%
Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.682
.658
.637

.610
.572
.540

.546
.501
.466

.488
.438
.399

.439
.385
.346

.452
.399
.359

70

50
30
10

.668
.646
.625

.599
.563
.535

.538
.495
.462

.480
.433
.396

.430
.381
.343

.488
.444
.410

.439
.392
.357

50

50
30
10

.640
.622
.606

.576
.547
.521

.520
.454
.433

.464
.423
.391

.418
.374
.341

.528
.496
.468

.473
.435
.405

.426
.384
.353

30

50
30
10

.615
.601
.587

.556
.532
.511

.502
.472
.446

.450
.415
.386

.406
.367
.337

.568
.544
.526

.512
.484
.460

.459
.426
.399

.414
.378
.349

10

50
30
10

.594
.581
.570

.537
.517
.499

.487
.461
.439

.437
.406
.381

.394
.361
.333

.512

.447

.385

.336

0

0

.557

.487

.426

.368

.321

Room Cavity Ratio
6
7
8

9

10

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.416
.359
.319

.375
.319
.281

.338
.283
.244

.309
.254
.217

.269
.215
.180

80

50
30
10

.396
.343
.305

.357
.304
.268

.322
.270
.234

.294
.242
.207

.256
.205
.172

70

50
30
10

.409
.356
.316

.370
.315
.278

.333
.281
.244

.305
.252
.217

.265
.215
.180

70

50
30
10

.390
.340
.302

.352
.301
.266

.317
.268
.233

.290
.240
.207

.252
.205
.172

50

50
30
10

.397
.350
.314

.359
.309
.276

.324
.277
.242

.297
.249
.215

.259
.211
.179

50

50
30
10

.378
.334
.300

.342
.295
.264

.309
.264
.231

.282
.237
.206

.247
.201
.171

30

50
30
10

.386
.344
.311

.348
.306
.273

.316
.272
.240

.289
.244
.214

.253
.208
.177

30

50
30
10

.368
.328
.298

.332
.292
.261

.301
.259
.230

.276
.233
.204

.241
.199
.169

10

50
30
10

.376
.338
.308

.341
.301
.271

.308
.268
.239

.282
.242
.212

.247
.205
.175

10

50
30
10

.358
.322
.294

.325
.288
.259

.294
.256
.228

.269
.231
.202

.235
.196
.168

0

0

.295

.258

.226

.200

.164

0

0

.283

.247

.217

.192

.157

% Reflectance
Eff. Ceil.
Wall

5L

3–40/T-12
0–30
1695
9450

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.721
.695
.673

.643
.603
.569

.575
.527
.489

.513
.459
.418

.461
.404
.362

70

50
30
10

.706
.683
.661

.631
.594
.564

.566
.520
.485

.505
.455
.415

50

50
30
10

.677
.657
.641

.607
.577
.549

.547
.508
.476

30

50
30
10

.650
.636
.621

.586
.561
.538

10

50
30
10

.627
.614
.602

0

0

.589

% Reflectance
Eff. Ceil.
Wall

1108

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

% Reflectance
Eff. Ceil.
Wall

Copyright© 2013 Eaton’s Crouse-Hinds Business

1108-1109.qxp

12/16/2013

6:55 PM

Page 1109

Cl. I, Div. 2, Groups A, B, C, D Cl. II, Div. 2, Groups F, G
Cl. II, Div. 1, Groups E, F, G (Canada)
Cl. I, Zone 1, Group IIC
Wet Locations
ATEX Certified
Enclosure Type 4X and IP66

eLLB20 Series
Recessed Mount
Fluorescent Luminaires
Applications:
eLLB Series Luminaires are used:
• For flush or surface ceiling mounting
• In clean room areas where it is
important to have smooth, flush
surfaces
• Where extreme cleanliness is required
as in pharmaceutical, chemical, and
electronics manufacturing facilities, as
well as in paint shops and spray booths
• For tough environmental conditions
involving corrosives, water, dust, and
extreme temperatures
• In areas that require lamps to reach full
illumination immediately
• Indoor and outdoor ordinary or
hazardous areas
• For wet locations and areas with hose
down / wash down requirements

Features and Benefits:

Certifications and
Compliances:
• NEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, AEx ed IIC
Class II, Division 2, Groups F, G
UL Listed
• CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, Ex eds IIC
Class II, Division 1, Groups E, F, G
cUL Listed
• Enclosure:
Type 4X
IP66
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
• CSA Standards:
C22.2 No. 9
CAN/CSA-E60079-0:02
CAN/CSA-E60079-1:02
CAN/CSA-E60079-7
CAN/CSA-E61241-1-1:02
Adjustable Mounting Clamps

ATEX
• ATEX Directive
94/9/EC
• Type of Protection

• EC-Type Examination
Certificate

Ex II 2 G
Ex II 2 D T80°C
Ex ed IIC T4
Ex ed ib IIC T4
(CG-variant)
DMT 02 ATEX E 069

Standard Materials:
• One-piece welded housing and cover
frame - sheet steel or stainless steel
• Lens – 6mm (1/4") thick tempered glass
• Gaskets – silicone
• External hardware – stainless steel

5L

• One-piece welded housing with fitted
cover frame; the cover frame is an
integral part of the housing to seal out
dust and moisture
• Adjustable mounting clamps:
Permanently attached and adjustable
through the cover frame for easy
installation
Allow recess mounting in ceilings from
25mm to 100mm (1" to 4" approx.) thick
for maximum mounting flexibility
• Support lugs (M8 x .6) to secure the
luminaire to ceiling structural support
members for safety
• Frameless tempered glass lens:
6mm (1/4") thick for added safety
Interior hinge for maximum dust
shedding
Fitted with captive screws for ease of
lamp replacement and maintenance
• Isolating switch turns off power to the
ballast and lamps when the lens is
opened for added safety
• 4 entries (2 on each end) supplied with
(2) 3/4" NPT adapter hubs and extra large
wire well for feed-through and tandem
applications without the need for
separate junction boxes
• Electronic ballast:
High power factor (95%) for energy
efficiency, more luminaires per circuit
and supply voltage flexibility
Features 2 channel circuitry for safety if one lamp fails, the 2nd lamp remains
in operation
• Uses T8 linear fluorescent lamps for high
efficiency and reduced operating costs
• 5 wire terminal block and through wiring
are standard for quick and easy
balancing of lighting loads on 3-phase
systems

5L

Hinged Glass Lens

Standard Finishes:
• Sheet steel – white epoxy coat
• Lens – clear
• Stainless steel – natural

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1109

1110-1111.qxp

5L

12/16/2013

6:55 PM

Page 1110

eLLB20 Series
Recessed Mount
Fluorescent Luminaires

Cl. II, Div. 2, Groups F, G
Cl. II, Div. 1, Groups E, F, G (Canada)
Wet Locations
Enclosure Type 4X and IP66

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, Group IIC
ATEX Certified

Ratings (Electrical / Size):

Temperature Performance Data:

Sources/Wattages
• Two 32W or 17W T8 Linear Fluorescent
Voltages
• 120–240V, 50–60 Hz
• 110–230VDC
Hub Size
• Four 25mm entries, 2 on each end, 3
plugged
• Two 3/4" NPT adapter hubs provided
standard, for feed-through or tandem
wiring
Terminals
• 5 wire terminal block, one on each end
(L1, L2, L3, N, Ground)
• Two 6mm2 (#10 AWG) maximum per
terminal

Minimum Starting Temperature: -20°C
Watts
Two 17W T8 lamps
Two 32W T8 lamps

Ambient Temp.

Cl. I, Div. 2
Cl. I, Zone 1 & 2

Class II

Supply
Wire Temp.

50°C
50°C

T4
T4

T6
T6

60°C
60°C

Accessories:
Description

Cat. #

• 3/4" NPT adapter hub

STM 2

Mounting Accessories:
• Eye Bolt for Support Lugs
• Hexagon Screw for Support Lugs

2 2480 002 000
2 2480 054 000

Ordering Information:
Cat. #
Hub
Size

Wattage/Lamp

Voltage/Hz

/4" NPT

Two 17 Watt T8 Rapid Start

120–240V, 50–60 Hz
110–230 VDC

3

120–240V, 50–60 Hz
110–230 VDC
IEC / CENELEC certified luminaries are available. Consult factory.
/4" NPT

3

Two 32 Watt T8 Rapid Start

Operating
Current

Epoxy Coated
Steel Enclosure

Stainless Steel
Enclosure

.18A

ELLB202217/U240

ELLB202217SS/U240

.34A

ELLB204232/U240

ELLB204232SS/U240

Dimensions (Inches) and Weights:

5L

Item
eLLB20 2217
eLLB20 4232

1110

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Weight
33 lbs.
48 lbs.

1110-1111.qxp

12/16/2013

6:55 PM

Page 1111

eLLB20 Series

5L

Photometric Data

Recessed Mount
Fluorescent Luminaires
Photometric Data:

Coefficients Of Utilization – Zonal Cavity Method
Effective Floor Cavity Reflectance 20%
Room Cavity Ratio

5L

Eff.
Ceil.

Wall

1

2

3

4

5

6

7

8

9

10

80*

50*
30*
10*

0.679
0.654
0.631

0.597
0.556
0.522

0.528
0.478
0.439

0.468
0.414
0.372

0.412
0.355
0.313

0.368
0.310
0.269

0.329
0.272
0.233

0.294
0.239
0.200

0.263
0.209
0.172

0.239
0.186
0.151

70*

50*
30*
10*

0.664
0.641
0.621

0.585
0.547
0.516

0.518
0.472
0.435

0.459
0.409
0.369

0.405
0.351
0.311

0.632
0.307
0.268

0.324
0.270
0.232

0.290
0.237
0.200

0.259
0.207
0.172

0.235
0.185
0.151

50*

50*
30*
10*

0.637
0.618
0.601

0.562
0.531
0.504

0.499
0.460
0.427

0.443
0.399
0.364

0.391
0.344
0.308

0.350
0.302
0.266

0.314
0.265
0.230

0.281
0.233
0.198

0.252
0.204
0.171

0.229
0.182
0.150

30*

50*
30*
10*

0.612
0.597
0.583

0.542
0.515
0.492

0.482
0.448
0.420

0.429
0.390
0.360

0.379
0.337
0.304

0.339
0.296
0.263

0.305
0.261
0.228

0.273
0.229
0.197

0.245
0.201
0.170

0.223
0.180
0.149

10*

50*
30*
10*

0.589
0.577
0.566

0.522
0.501
0.481

0.465
0.437
0.413

0.415
0.382
0.355

0.367
0.330
0.301

0.329
0.291
0.261

0.296
0.257
0.257

0.265
0.226
0.196

0.238
0.198
0.169

0.217
0.177
0.149

0*

0*

0.553

0.468

0.400

0.341

0.288

0.248

0.214

0.183

0.156

0.137

*Percent Reflectance.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1111

1112-1113.qxp

12/16/2013

6:55 PM

Page 1112

Paint Spray (Suffix S718)
Wet Locations (Suffix S718)
3, 3R, IP54 (Suffix S718)

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1, Group IIB
Cl. II, Div. 1, Groups E, F, G
Cl. III, Simultaneous Presence

EVF Series
Fluorescent Luminaires

5L

Applications:
• EVF Luminaires are used in areas where
hazardous fumes, gases, or dusts are
present
• EVF Luminaires with S718 option are
designed specifically for use inside paint
spray booths where hazardous fumes,
gases, and paint residue are present;
this includes powder paint process areas
• EVF Luminaires with S718 option are
also suitable for use in wet locations

Furnished For
Use with

5L

All EVF Luminaires:
• Provide cool, even light with natural color
rendition
• Reduce relamping schedule (long lamp
life)
• Continuous and uniform illumination
made possible by mounting end to end
(no space needed between luminaires for
relamping)
• No special tools required for relamping;
threaded lamp tube cover provides quick
and easy access for relamping
• Threaded joints on lamp tube and wiring
chamber covers permit easy access for
lower maintenance costs
• Reflectors can be removed or replaced
with only a screwdriver
• Easy to install; factory-sealed and wired
luminaire facilitates installation
• Standard electronic ballast for 32 watt
and 40 watt rapid start luminaires
• Standard energy-efficient ballast for 40
watt slimline, 60 watt and 110 watt
luminaires
• Low temperature ballast is supplied as
standard on 32 watt T8 (0°F), 40 watt
slimline (0°F), 60 watt and 110 watt
luminaires (-20°F)
• All exposed hardware is stainless steel
for maximum protection against
corrosion, and for longer luminaire life
• Copper-free aluminum construction
throughout means lighter luminaire
weight, easier installation, and excellent
corrosion resistance
• All exterior materials are non-sparking
• Type P ballasts furnished in compliance
with NEC
• Heavy-duty glass lamp tubes provide
maximum strength and impact resistance
to protect lamps

EVF Luminaires with S718 Option:
• All joints sealed
• Inside paint booth mounting capabilities
provide greater flexibility in luminaire
placement, avoids necessity of
complicated design and installation work,
and improves task lighting control
• Smooth, simple design makes it easy to
remove any accumulated deposits of
paint residue

www.crouse-hinds.com

2-lamp with angle reflector

Ordering Information:

Features:

1112

3-lamp

Hub Line Volts 1-Lamp
Size 60 Hz
Cat. #

2-Lamp
Cat. #

3-Lamp
Cat. #

4-Lamp
Cat. #

32 watt, T-8 medium 3/4"
Bi-pin 265MA lamps 3/4"

120–277
347

EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV
EVF21029/347 EVF22029/347 EVF23029/347 EVF24029/347

40 watt, T-12 medium 3/4"
3
Bi-pin rapid start
/4"
3
430MA lamps†
/4"

110–125
277
347

EVF21082
EVF22082
EVF23082
EVF24082
EVF21087
EVF22087
EVF23087
EVF24087
EVF21089/347 EVF22089/347 EVF23089/347 EVF24089/347

/4"
/4"
/4"

110–125
277
347

EVF21032
EVF22032
EVF23032
EVF24032
EVF21037
EVF22037
EVF23037
EVF24037
EVF21039/347 EVF22039/347 EVF23039/347 EVF24039/347

3

/4"
/4"
3
/4"

110–125
277
347

EVF21062
EVF22062
EVF23062
EVF24062
EVF21067
EVF22067
EVF23067
EVF24067
EVF21069/347 EVF22069/347 EVF23069/347 EVF24069/347

/4"
/4"
3
/4"

110–125
277
347

EVF21072
EVF22072
EVF23072
EVF24072
EVF21077
EVF22077
EVF23077
EVF24077
EVF21079/347 EVF22079/347 EVF23079/347 EVF24079/347

40 watt, T-12 single
pin, slimline
425MA lamps

3

60 watt, T-12
recessed contact,
800MA lamps†

3

110 watt, T-12
recessed contact,
1500MA lamps†

3

3
3

3

†50 Hz not available.

Certifications and
Compliances:

Options:
Description

Suffix

• For suitability for wet
• NEC and CEC:
locations and locations
Class I, Division 1, Groups C, D
having deposits of
Class I, Zone 1, Group IIB
readily combustible
Class II, Groups E, F, G
paint residue ...................
Class III
• Corro-free™ epoxy
Simultaneous Presence (Cl. I
powder coat....................
• With 45° angle reflectors
and Cl. II)
in lieu of straight down
Paint Spray (S718)
reflectors .........................
• UL Standards:
• Fused (not suitable for
844 Hazardous (Classified)
marine applications)........
Locations
• Furnished with lamps......
1598 Luminaires
• Low temperature
• CSA Standards:
electromagnetic ballast
C22.2 No. 137
for 40 watt T12 rapid
start luminaires rated
for 0°F .............................
• Copper-free aluminum except
sheet aluminum reflectors

Standard Materials:

S718
S752
S369
S658
S714

US: 1-866-764-5454

Various hazardous area
fittings are used to mount
EVF Luminaires. The fittings
shown on next page support
the unwired (relamping) end.
For the wired (ballast) end
any of the luminaire hangers
for hazardous locations
(listed in Section 7L) can be
used. CPS conduit outlet
bodies with hub covers
(listed in Section 3F) are also
suitable.

Size Ranges:
BY

• 1, 2, 3, and 4-lamp

Electrical Rating
Ranges:

Standard Finishes:
• Natural except reflectors
• Reflectors – white epoxy
powder coat

Mounting
Accessories:

• 32 to 110 watts

Temperature Performance Data:
(Based on 40°C Ambient)
Class I/Class II/Zone 1
Lamp Type 1-Lamp 2-Lamp 3-Lamp 4-Lamp Supply Wire
32/40W
60W
110W

CAN: 1-800-265-0502

T5
T5
T4

T5
T5
T4

Copyright© 2013 Eaton’s Crouse-Hinds Business

T5
T5
T4

T5
T5
T4

75°C
75°C
90°C

1112-1113.qxp

12/16/2013

6:55 PM

Page 1113

Accessories
Relamping Information

EVF Series
Fluorescent Luminaires

Ceiling Saddle

5L

Relamping Information

Conduit Support
Size
(In.) Cat. #

Description
Ceiling Saddle for
Conduit Support

/4

3

EVF20

Ceiling Saddle
Support Hook
Adjacent ends of two fixtures
suspended in line close together
Description

Cat. #

Ceiling Saddle for
Support Hook

EVF021

One cover removed and
lamp partly withdrawn
Where fixtures abut, space for
relamping is obtained by lowering
one end of the tube assembly as
shown. Without tools, the lamp
receptacle and mounting plate
assemblies can be removed and
the lamp withdrawn. In inserting,
the reverse procedure is followed.

Support Hook
for Conduit
Description
Support Hook
for Conduit

Size
(In.)

Cat. #

/4

EVF21

3

End of one fixture
lowered for relamping

Dimensions:
5L

End view

Fixture Type
32 watt, T-8 Bi-pin
40 watt, T-12 Bi-pin
40 watt, T-12 Single pin slimline
60 watt, T-12 Recessed contact
110 watt, T-12 Recessed contact

No. Lamps

1 or 2
3 or 4

www.crouse-hinds.com

a

b

44
11
461/2 81/2

c

d

533/8 55
533/8 55

US: 1-866-764-5454

e

f

95 101/4
100 101/4

CAN: 1-800-265-0502

No. of Lamps
1-Lamp
2-Lamp
3-Lamp
4-Lamp

Width
61/8
111/2
18
241/2

Copyright© 2013 Eaton’s Crouse-Hinds Business

1113

1114-1115.qxp

12/16/2013

6:56 PM

Page 1114

Luminaire: All 1-Lamp EVF Luminaires
Lamp:
Zonal Degrees:
Zonal Lumens:
Total Bare Lamp Lumens:

1-40/T-12, 1-60/T-12
0–30
0–40
580
953
3100

Luminaire: All 2-Lamp EVF Luminaires

0–60 0–90
1633 1897

2-40/T-12, 2-38/T-12, 2-60/T-12, 2-110/T12
Lamp:
0–30
0–40
0–60
0–90
Zonal Degrees:
1055
1765
3262
4125
Zonal Lumens:
Total Bare Lamp Lumens: 6300

All data provided is for 40W rapid
start cool white lamps. Use
following candlepower/lumen
multipliers for other lamp sizes:
32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

All data provided is for 40W rapid
start cool white lamps. Use
following candlepower/lumen
multipliers for other lamp
sizes: 32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

Example: Zonal lumens of 1–40W
lamp for 0–60° is 1633. Zonal
lumens of 1–60W lamp for 0–60 is
1633 x 1.29 = 2107

Example: Zonal lumens of 2–40W
lamp for 0–60° is 3262. Zonal
lumens of 2–60W lamps for 0–60
is 3262 x 1.29 = 4208

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

% Reflectance
Eff. Ceil.
Wall

5L

Photometric Data

EVF Series
Fluorescent Luminaires

5L

Room Cavity Ratio
1
2
3

4

5

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.697
.670
.647

.616
.574
.539

.546
.497
.458

.485
.430
.388

.434
.376
.334

80

50
30
10

.697
.670
.647

.616
.574
.539

.546
.497
.458

.485
.430
.388

.434
.376
.334

70

50
30
10

.682
.658
.635

.604
.565
.534

.538
.490
.454

.477
.426
.385

.425
.372
.331

70

50
30
10

.682
.658
.635

.604
.565
.534

.538
.490
.454

.477
.426
.385

.425
.372
.331

50

50
30
10

.653
.633
.616

.580
.549
.520

.518
.478
.446

.460
.416
.380

.412
.365
.329

50

50
30
10

.653
.633
.616

.580
.549
.520

.518
.478
.446

.460
.416
.380

.412
.365
.329

30

50
30
10

.627
.612
.597

.559
.533
.509

.500
.467
.438

.445
.407
.375

.399
.357
.325

30

50
30
10

.627
.612
.597

.559
.533
.509

.500
.467
.438

.445
.407
.375

.399
.357
.325

10

50
30
10

.605
.591
.579

.539
.517
.498

.484
.455
.431

.431
.397
.370

.388
.351
.321

10

50
30
10

.605
.591
.579

.539
.517
.498

.484
.455
.431

.431
.397
.370

.388
.351
.321

Room Cavity Ratio
6
7
8

9

10

.391
.334
.294

.351
.295
.257

.316
.262
.223

.289
.235
.197

.252
.198
.164

% Reflectance
Eff. Ceil.
Wall

% Reflectance
Eff. Ceil.
Wall

9

10

80

50
30
10

Room Cavity Ratio
6
7
8
.316
.391
.351
.334
.295
.262
.294
.257
.223

.289
.235
.197

.252
.198
.164

80

50
30
10

70

50
30
10

.384
.330
.290

.346
.292
.255

.312
.260
.222

.285
.233
.197

.248
.198
.164

70

50
30
10

.384
.330
.290

.346
.292
.255

.312
.260
.222

.285
.233
.197

.248
.198
.164

50

50
30
10

.372
.324
.288

.336
.286
.252

.303
.255
.221

.277
.229
.196

.242
.195
.162

50

50
30
10

.372
.324
.288

.336
.286
.252

.303
.255
.221

.277
.229
.196

.242
.195
.162

30

50
30
10

.361
.319
.286

.325
.283
.249

.295
.251
.219

.270
.225
.194

.236
.192
.161

30

50
30
10

.361
.319
.286

.325
.283
.249

.295
.251
.219

.270
.225
.194

.236
.192
.161

10

50
30
10

.351
.312
.283

.318
.278
.248

.287
.247
.218

.263
.222
.193

.230
.189
.159

10

50
30
10

.351
.312
.283

.318
.278
.248

.287
.247
.218

.263
.222
.193

.230
.189
.159

1114

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1114-1115.qxp

12/16/2013

6:56 PM

Page 1115

EVF Series
Fluorescent Luminaires

Luminaire: All 4-Lamp EVF Luminaires

Luminaire: All 3-Lamp EVF Luminaires
Lamp:
Zonal Degrees:
Zonal Lumens:
Total Bare Lamp Lumens:

5L

Photometric Data

3-40/T-12, 3-38/T-12, 3-60/T-12, 3-110/T-12
0–30
0–40
0–60
0–90
1917
3226
6066
7919
9300

4-40/T-12, 4-38/T-12, 4-60/T-12, 4-110/T-12
Lamp:
0–30
0–40
0–60
0–90
Zonal Degrees:
1961
3305
6250
8224
Zonal Lumens:
Total Bare Lamp Lumens: 12400

All data provided is for 40W rapid
start cool white lamps. Use
following candlepower/lumen
multipliers for other lamp
sizes:
32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

All data provided is for 40W rapid
start cool white lamps. Use
following candlepower/lumen
multipliers for other lamp
sizes:
32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

Example: Zonal lumens of 3–40W
lamps for 0–40° is 3226. Zonal
lumens of 3–40W Slimline lamps for
0–40° is 3226 x 0.84 = 2710

Example: Zonal lumens of 4–40W
lamps for 0–30° is 1961. Zonal
lumens of 4–110W Slimline lamps
for 0–30° is 1961 x 2.19 = 4295

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

% Reflectance
Eff. Ceil.
Wall

4

5

80

50
30
10

.712
.683
.658

.626
.581
.544

.553
.500
.459

.489
.431
.386

.436
.376
.331

70

50
30
10

.697
.670
.646

.614
.572
.539

.544
.494
.455

.481
.426
.383

50

50
30
10

.667
.645
.626

.589
.555
.524

.524
.481
.446

30

50
30
10

.640
.623
.607

.567
.539
.513

10

50
30
10

.617
.602
.589

.547
.523
.502

Room Cavity Ratio
1
2
3

4

5

80

50
30
10

.692
.664
.639

.607
.563
.526

.535
.484
.442

.473
.416
.372

.421
.362
.318

.427
.371
.328

70

50
30
10

.678
.652
.628

.595
.554
.521

.526
.477
.439

.465
.411
.369

.412
.357
.315

.463
.416
.378

.414
.364
.326

50

50
30
10

.648
.627
.609

.571
.538
.507

.507
.465
.431

.447
.401
.364

.399
.351
.313

.505
.469
.439

.447
.407
.374

.400
.356
.322

30

50
30
10

.622
.606
.590

.550
.522
.497

.488
.453
.423

.432
.392
.360

.386
.343
.309

.488
.457
.431

.433
.397
.368

.388
.350
.318

10

50
30
10

.600
.585
.572

.530
.506
.486

.472
.442
.416

.418
.383
.354

.374
.337
.305

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.392
.332
.290

.352
.293
.254

.317
.260
.219

.289
.233
.194

.252
.196
.160

70

50
30
10

.385
.329
.287

.347
.290
.251

.312
.258
.218

.285
.230
.194

50

50
30
10

.372
.322
.285

.336
.284
.248

.303
.253
.217

30

50
30
10

.362
.317
.282

.325
.280
.245

10

50
30
10

.351
.310
.279

.317
.276
.244

% Reflectance
Eff. Ceil.
Wall

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.379
.320
.278

.340
.282
.243

.306
.250
.210

.279
.224
.185

.243
.189
.153

.248
.196
.160

70

50
30
10

.372
.316
.275

.335
.279
.240

.301
.248
.209

.275
.221
.185

.239
.189
.153

.277
.227
.192

.242
.193
.159

50

50
30
10

.359
.310
.273

.324
.273
.238

.292
.243
.208

.267
.218
.184

.233
.185
.152

.295
.248
.215

.269
.223
.191

.236
.190
.157

30

50
30
10

.349
.305
.271

.313
.269
.235

.284
.238
.206

.260
.214
.183

.227
.182
.150

.286
.244
.214

.262
.220
.189

.230
.187
.156

10

50
30
10

.339
.298
.268

.306
.265
.234

.276
.235
.205

.253
.211
.181

.221
.179
.149

www.crouse-hinds.com

US: 1-866-764-5454

% Reflectance
Eff. Ceil.
Wall

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1115

5L

Room Cavity Ratio
1
2
3

1116-1117.qxp

12/23/2013

5L

3:15 PM

Page 1116

EVFDR Series
Fluorescent Luminaires

Marine & Wet
Locations
3, 3R, 4, 4X; IP66

Cl. I, Div. 1, Groups C, D
Cl. I, Zone 1, Group IIB
Cl. II, Div. 1, Groups E, F, G
Cl. III, Simultaneous Presence

Applications:
• EVFDR Luminaires are suitable for wet
locations and marine environments,
above and below deck, where hazardous
vapors, gases or dusts are present
• Ideally suited for use on offshore
drilling/production platforms and on
shipboard in hazardous areas
• For mounting where headroom is limited
• For hazardous areas where
watertightness and corrosion resistance
are required

5L

Features:
• Exterior surfaces finished with gray
epoxy enamel for corrosion resistance
• Exterior hardware stainless steel
• All joints sealed and gasketed for
watertightness
• Vibration resistant
– Shock mounts
– Sockets are spring loaded for tight
lamp contact connection
• Heavy duty glass lamp tubes for
maximum strength and impact resistance
• All exterior materials are non-sparking
• C-type beam clamps provide quick and
easy mounting
• Luminaire is adjustable 30° either side of
fixture axis, allowing for control of light
output
• Beam clamp support is adjustable
allowing beam clamp to be located to
suit structure
• Low profile – luminaire height is 713/16"
with standard mounting, 1111/16" with
shock mounting option – for maximum
clearance where headroom is critical
• Provides cool light with natural color
rendition
• Continuous and uniform illumination
made possible by mounting end to end
(no space needed between luminaires for
relamping) – see page 1113 for
relamping information
• Relamping is accomplished without
tools; quarter-turn fastener allows end of
luminaire to be lowered quickly; cable
supports end of luminaire while
relamping – both hands are free;
threaded lamp tube cover provides quick
and easy access to lamp and receptacle
• Reflectors can be removed or replaced
with only a screwdriver
• Ballast housing readily accessible
• Minimum weight – copper-free aluminum
construction throughout
• Type P ballast furnished in compliance
with NEC
• Standard electronic ballast for 32 watt
and 40 watt rapid start

1116

www.crouse-hinds.com

US: 1-866-764-5454

• Standard energy-efficient
electromagnetic ballast (40W slimline,
60W and 110W) is standard
• Low temperature ballasts are standard
on 32W T8, 40W slimline, 60W and
110W; 32 watt and 40 watt low
temperature ballasts are rated for 0°F;
60 and 100 watt low temperature
ballasts are rated for -20°F

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 1, Groups C, D
Class I, Zone 1, Group IIB
Class II, Groups E, F, G
Class III
Simultaneous Presence (Cl. and Cl. II)
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137

Standard Materials:

Options:
Description
Suffix
• Furnished with lamps.................... S714
• Furnished with safety cable
for high vibration areas................. S715
• Beam clamps with shock
mounts are available for ease
of installation and resistance
to vibration.................................... KIT40
• Beam clamps only........................ KIT41
• Low temperature
electromagnetic ballast: 40W
rapid start rated 0°F......................
BY
• Emergency lighting battery unit.... S799

Size Ranges:
• 2–lamp only

Electrical Rating Ranges:
• 32, 40, 60 and 110W

Temperature Performance
Data:
(Based on 40°C Ambient)
2-Lamp
32, 40W
60W
110W

• Housing – copper-free aluminum
• Exposed hardware – stainless steel

Class I
Class II
Zone 1

Supply
Wire

T5
T5
T4

75°C
75°C
90°C

Standard Finishes:
• All exterior metal components – gray
epoxy enamel
• Reflectors – white epoxy powder coat

Ordering Information:
Furnished For
Use With

Hub
Size

Line Volts
60 Hz.

2-Lamp
Cat. #

32 watt, T-8 medium
Bi-pin 265MA lamps

3

/4"
/4"

120–277
347

EVFDR22029/UNV
EVFDR22029/347

40 watt, T-12 medium
Bi-pin rapid start
430MA lamps†

3

/4"
/4"

110–125
277

EVFDR22082
EVFDR22087

60 watt, T-12 recessed
contact, 800MA lamps
110 watt, T-12 recessed
contact, 1500MA lamps†

3

/4"
/4"

110–125
277

EVFDR22062
EVFDR22067

/4"
/4"

110–125
277

EVFDR22072
EVFDR22077

3

3

3
3
3

†50 Hz not available.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1116-1117.qxp

12/23/2013

3:15 PM

Page 1117

Photometric Data and Dimensions

EVFDR Series
Fluorescent Luminaires

Luminaire: All EVFDR Luminaires
Lamp:
Zonal Degrees:
Zonal Lumens:
Total Bare Lamp Lumens:

5L

Dimensions:

2-40/T-12, 2-60/T-12, 2-110/T-12
0–30
0–40
0–60
0–90
1416
2352
4263
5863
8600
All data provided is for two 60
watt, T-12 recessed contact
800MA cool white lamps
(EVFDR22062). For other
wattages use the following
conversion factors:
32W
40W, Rapid Start
40W, Slimline
110W, Cool White

.67
.73
.70
1.60

Example: Zonal lumens for
EVFDR226 fixture, across the
axis, for 40–50" is 1,060. Zonal
lumens for EVFDR223 fixture,
across the axis, is 40–50" is:
1,060 x .70 = 742

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall

4

5

80

50
30
10

.735
.700
.670

.645
.594
.551

.570
.512
.466

.506
.442
.394

.452
.387
.339

70

50
30
10

.714
.682
.653

.627
.580
.542

.557
.501
.458

.494
.435
.388

.440
.380
.334

50

50
30
10

.673
.647
.624

.593
.554
.520

.528
.482
.444

.468
.418
.378

.420
.368
.327

30

50
30
10

.636
.616
.596

.562
.530
.502

.501
.463
.430

.446
.403
.368

.401
.354
.319

10

50
30
10

.603
.585
.570

.533
.507
.483

.477
.444
.416

.425
.388
.358

.383
.343
.311

0

0

.551

.465

.399

.340

.294

Room Cavity Ratio
6
7
8

9

10

80

50
30
10

.408
.344
.298

.368
.305
.262

.332
.271
.228

.304
.243
.202

.266
.207
.169

70

50
30
10

.398
.338
.293

.360
.299
.258

.325
.267
.226

.297
.240
.201

.260
.206
.168

50

50
30
10

.380
.327
.287

.344
.289
.252

.311
.259
.221

.285
.233
.197

.250
.199
.164

30

50
30
10

.364
.317
.281

.328
.282
.246

.299
.251
.217

.274
.226
.193

.240
.193
.160

10

50
30
10

.348
.306
.274

.316
.274
.241

.286
.244
.213

.263
.220
.189

.231
.188
.157

0

0

.259

.226

.198

.175

.144

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

US: 1-866-764-5454

5L

Room Cavity Ratio
1
2
3

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1117

1118-1119.qxp

12/16/2013

6:56 PM

Page 1118

5L

5L

1118

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1118-1119.qxp

12/16/2013

6:56 PM

Page 1119

6L

Champ-Pak™ Wall Pack &
Floodlight Luminaires
Hazardous and Non-hazardous
Description

Page No.

Application/Selection

see page 1120

Floodlights
Champ-Pak™
CPMV

see page 1121

H.I.D.
FMV nR Series
FMV1000 nR High Wattage Series
Voyager nR™ Stainless Steel Series
F2MV Mini Floodlight Series
FZD Series
EVMA S812 Hazard•Gard with Trunnion Arm

see
see
see
see
see

pages 1135–1138
pages 1139–1141
pages 1142–1145
pages 1150–1153
pages 1154–1156
see page 1157

Incandescent
RCDE Series

see pages 1158–1159

LED
Champ® Pro PFM Series
Champ® Pro PFM25L and 50L Series
Champ® FMV Series

see pages 1128–1129
see pages 1130–1132
see pages 1146–1149

6L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1119

1120-1121.qxp

12/16/2013

6L

6:56 PM

Page 1120

Champ-Pak™ Wall Pack &
Floodlight Luminaires

Applications:

Considerations for
Selection:

• General illumination of hazardous and
non-hazardous areas

Environmental:
• What is the hazardous area
classification NEC®/CEC) of the location
in which the luminaires will be installed?
Lighting levels required:
• What wattage luminaire(s) will provide
the desired light levels?
Physical arrangement:
• Type of luminaire mounting required,
threaded hub or mounting feet

Table 500.8(C)
Identification Numbers
Maximum
Temperature
Deg. C Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Application and Selection
Quick Selector Chart

Temperature
Class
(T Code)
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Quick Selector Chart
NEC Hazardous Area
Compliance

Lamp Size
(Watts)

Lamp
Base

CPMV

Cl. I, Division 2

50–150 HID

Mogul

EVMA-S812

Cl. I, Groups C, D
Cl. I, Groups B (suffix GB), C, D

50–400 HID

Mogul

VOYAGER nR (SSFMV)

Cl. I, Division 2
Cl. I, Zone 2

150–400 HID

Mogul

6L

Luminaire

F2MV, FMV, FMV High Wattage

Cl. I, Division 2

70–1500 HID

Mogul

FZD

Cl. I, Division 1, Groups B, C, D

150–400 HID

Mogul

RCDE-6

Cl. I, Groups C, D
Cl. I, Group D

150 Incandescent
300 Incandescent

Medium

RCDE-10

Cl. I, Group D

500 Incandescent

Extended Mogul End Prong

PFM

Non-hazardous areas

64–179 LED

PFM25L/PFM50L

Non-hazardous areas

263–531 LED

FMV

Cl.
Cl.
Cl.
Cl.

64–179 LED

1120

www.crouse-hinds.com

I, Division 2, Groups A, B, C, D
I, Zone 2
II, Groups E, F, G
III

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1120-1121.qxp

12/16/2013

6:56 PM

Page 1121

Champ-Pak™ Wall Pack
Luminares

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2 &
Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups F, G
Cl. III & Simultaneous Presence
Marine & Wet Locations
Enclosure Type 4X, IP66

6L

The first low-profile wall pack designed
specifically for hazardous areas.
The Eaton's Crouse-Hinds Champ-Pak™ Wall Pack Luminaire is
ideal for low-profile mounting in hazardous and industrial
environments. In fact, it is suitable for any area with adverse
conditions such as dust, dirt, moisture, vibration, high-pressure
hose downs, and high thermal ambients. Its precisely designed
glass refractor minimizes fixture depth while providing uniform,
glare-free illumination.
• Unique compact shallow-profile design mounts virtually anywhere
• Side-hinged cover with two-screw closing for easy installation and
maintenance
• Gray Corro-free™ epoxy powder coated two-piece housing
provides superior corrosion resistance
• Unique stainless steel wire guard accessory attaches without any
additional hardware for easy installation and maintenance
• Glass refractor provides uniform light distribution to eliminate
glare
• Vertical lamp design provides even lamp heat distribution for
cooler operation, providing expanded hazardous area suitability
• Silicone gaskets make luminaire suitable for enclosure Type 4X,
marine, and IP66 environments
• Available in two different conduit entry configurations to permit
flexible installation and mounting
• Four 3/4" NPT hubs, one on each side
• Two 1/2" NPT hubs on bottom for feed-through applications

Additional Features and Benefits:

• Indoor and outdoor wall mounting or
vertical surface mounting where minimal
fixture depth is required in:
• Manufacturing plants and heavy
industrial facilities
• Industrial process facilities such as
refineries, chemical, petrochemical,
pharmaceutical, and production
platforms
• Waste or sewage treatment plants
• Offshore, dockside, and harbor
installations
• For security and safety lighting in
industrial facilities
• For lighting of loading docks, tunnels,
and stairways
• For marine, wet location, hose down,
and corrosive environments

• Variety of lamp types and wattages–HID,
fluorescent, and induction–to meet
specific lighting needs
• High power-factor ballasts (+90%) are
standard, which allow more luminaires
per circuit
• Up to 65°C ambient suitability on select
lamp types and wattages; ambient
suitability of +40°C is standard; allows
for installation in higher ambient
environments commonly found in
industrial facilities
• Low ambient starting capability (to
-40°C) – perfect for colder climates
• Shock-absorbing HID mogul base lamp
socket cushions lamp, improves lamp
life in harsh environments

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

6L

Applications:

• Compact fluorescent emergency
luminaire provides 90 minutes of lighting
during power outages, meeting UL924
and Life Safety Code
• Cost-effective induction lamp system
provides extra long lamp life up to
100,000 hours; reaches full illumination
immediately, providing crisp, white light
• NEC/CEC restricted breathing
construction is available to provide
cooler temperature classes (T codes) for
expanded hazardous area suitability
• Simplified method for compliance to
NEC restricted breathing conduit
sealing requirements makes installation
easier

Copyright© 2013 Eaton’s Crouse-Hinds Business

1121

1122-1123.qxp

6L

12/16/2013

6:56 PM

Page 1122

Champ-Pak™ Wall Pack
Luminares

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups F, G
Cl. III & Simultaneous Presence
Marine & Wet Locations
Enclosure Type 4X, IP66

Certifications and Compliances:

Ratings (Electrical/Size):

• Luminaires For Use With ANSI Lamps (Mogul Base):
UL/cUL Listed
NEC and CEC Class I, Division 2 and Class I, Zone 2
Restricted Breathing Class I, Division 2 and Zone 2 (suffix S826)
Class II, Groups F, G
Class III
Simultaneous Presence
Certified for IEC Zone 2 (suffix S826TB)
Wet Locations; Marine Locations; Enclosure Type 4X; IP66
• UL Standards:
844 – Hazardous (Divisions Classified) Locations
1598 – Luminaires
1598A – Luminaires for Marine Vessels
924 – Emergency Lighting (Fluorescent Emergency Luminaire)
• CSA Standards:
C22.2 No. 9 and 137
CAN/CSA-E60079-15:02
• IEC Standards:
60079-15

Sources/Wattages
•
•
•
•
•

Voltages

Standard Materials:
•
•
•
•
•
•

Fixture housing and door frame assembly – copper-free aluminum
External hardware – stainless steel
Refractor lens – borosilicate glass
Gasket – silicone
Reflector – aluminum light sheet
Wire guard – stainless steel

Standard Finishes:

6L

• Aluminum – Corro-free™ epoxy powder coat
• Stainless steel – natural

High-pressure sodium (HPS) – mogul base 50, 70, 100 & 150
Metal halide (MH) – mogul base 70, 100 & 150
Compact fluorescent 26, 32, 42, 52, 64 & 84
Emergency fluorescent 26
Induction 55 & 85

HID Standard-Voltage Ballasts
• Dual tap (120 & 277 V, 60 Hz–for 50 W HPS only)–prewired at 277 V
• Multi-tap (120, 208, 240 & 277 V, 60 Hz)–prewired at 277 V
• Tri-tap (120, 277 & 347 V, 60 Hz)–prewired at 347 V
• 120 V, 60 Hz
• 480 V, 60 Hz
Fluorescent Standard Voltage Ballasts
• 120–277 V, 50–60 Hz
• 120 V, 50 Hz (for Canada only)
• 347 V, 60 Hz (for Canada only)
Induction Standard Voltage Ballasts
• 120 V, 50–60 Hz (also 120 V DC)
• 230 V, 50–60 Hz (also 240 V DC)
HID Optional Voltage Ballasts
• 220 V, 50 Hz
• 220 V, 60 Hz
• 240 V, 50 Hz
Fluorescent Optional Voltage Ballasts (Consult Factory)
• 125 V DC
• 12 V DC
• 24 V DC
Isolated Ballasts And Specials (Consult Factory)
• 208 V, 60 Hz CWI Isolated Ballast
• 240 V, 60 Hz CWI Isolated Ballast
• 480 V, 60 Hz CWI Isolated Ballast

Conduit Entries
• Four 3/4" NPT entries, one on each side, top and bottom (3
plugged)
• Two 1/2" NPT entries on bottom for feed-through (1 plugged)
• Metric entries – consult factory

1122

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1122-1123.qxp

12/16/2013

6:56 PM

Page 1123

Champ-Pak™ Wall Pack
Luminares

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Lamp
Watts

Cat. #

Hub Size

Lamp
Watts

Cat. #

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

26 (one 26 W lamp)

CPMVF2W026
CPMVF1W026

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

32 (one 32 W lamp)

CPMVF2W032
CPMVF1W032

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

42 (one 42 W lamp)

CPMVF2W042
CPMVF1W042

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

CPMVF2W052
52 (two 26 W lamps) CPMVF1W052

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

CPMVF2W064
64 (two 32 W lamps) CPMVF1W064
84 (two 42 W lamps)

50

CPMVS2W050
CPMVS1W050

70

CPMVS2W070
CPMVS1W070

Four /4" NPT (one each side)
Two 1/2" NPT (on bottom)

100

CPMVS2W100
CPMVS1W100

Four /4" NPT (one each side)
Two 1/2" NPT (on bottom)

CPMVS2W150
150
(for 55 V lamp) CPMVS1W150

Metal Halide
Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

70

CPMVM2W070
CPMVM1W070

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

100

CPMVM2W100
CPMVM1W100

Voltage Suffixes:

150

CPMVM2W150 S828
CPMVM1W150 S828

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)
3

3

Metal Halide–Pulse Start
Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

To complete Catalog Number, add Voltage and Option suffix(es).

Voltage Suffixes:
Voltage (60 Hz)
Suffix
Voltage (60 Hz)
Suffix

Dual Tap
/DT
Dual Tap
/DT

6L

Ordering Information
Fluorescent Luminaires:

Ordering Information
HID Luminaires:
Hub Size
High-Pressure Sodium
Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

Cl. II, Groups F, G
Cl. III & Simultaneous Presence
Marine & Wet Locations
Enclosure Type 4X, IP66

NEC/UL
Multi Tap
/MT

120
/120

480
/480

CEC (CSA/cUL)
Tri Tap
120
/TT
/120

NEC/CEC (UL, CSA, cUL)
120–277 V
(50–60 Hz)
/UNV

Voltage
Suffix

CPMVF2W084
CPMVF1W084

CEC (CSA, cUL)
347 V
(60 Hz)
/347

Ordering Information
Fluorescent Emergency Luminaires
– Continuous Operation:
Lamp
Watts

Hub Size

Cat. #

CPMVFB2W026
Four /4" NPT (one each side)
26 (one 26 W lamp)
Two 1/2" NPT (on bottom)
CPMVFB1W026
3

50W HPS is available only with suffix /DT.

Voltage Suffixes:
Voltage
Suffix

Lamp
Watts

Cat. #

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

55

CPMVIG2W055
CPMVIG1W055

Four 3/4" NPT (one each side)
Two 1/2" NPT (on bottom)

85

CPMVIG2W085
CPMVIG1W085

Hub Size

Voltage Suffixes:
Voltage

120 V (also 120 V DC)
(50–60 Hz)

230 V (also 240 V DC)
(50–60 Hz)

Suffix

/120

/230

www.crouse-hinds.com

US: 1-866-764-5454

NEC/CEC (UL, CSA, cUL)
120–277 V
(50–60 Hz)
/UNV

CEC (CSA, cUL)
120 V
347 V
(60 Hz)
(60 Hz)
/120 CAN
/347

Compelling reasons to choose the Champ
induction luminaire as the light source for industrial
and hazardous locations include:
• Crisp, white light (80+ color rendering index) provides increased
safety by clearly illuminating signs, instrument panels, equipment,
and more with vibrant natural colors
• Up to 100,000 hours of lamp life minimizes routine maintenance
costs; if you operate this luminaire for 24 hours, 7 days a week,
you will not need to change the lamp for up to 11 years!
• Instant illumination – no waiting for lamp warm-up time; increases
productivity and safety
• Delivers the best possible luminaire temperature rating – T6 (85°C)
when used with the Champ restricted breathing option; ideal for
hazardous areas where a low ignition temperature is required
• Starts in low temperatures – as low as -40°C

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1123

6L

Ordering Information
Induction Luminaires With Lamp
(100,000 hours):

1124-1125.qxp

12/16/2013

6L

6L

6:56 PM

Page 1124

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Champ-Pak™ Wall Pack
Luminares

Options:

Accessories:

Description
Suffix
Ballast-Gard™ starter cut-out switch ...................................... BG
• Not available with IR or QTZ options
Factory Assembled with Lamp Installed..................................
FA
Instant Restrike ..........................................................................
IR
• Not available with BG or QTZ options
Guard—Factory Installed on Luminaire ...................................
P
(Guard suffix follows wattage designation, e.g.,
CPMVS2W100P/MT)
Quartz Auxiliary .......................................................................... QTZ
Fused ........................................................................................... S658*
• Not available with CPMVIG and CPMVFB luminaires
• Not suitable for marine applications
Restricted Breathing Construction (AEx nR, Ex nR)............... S826

(Order Separately)
Description
Photocell For Field Installation
• 120 V, 50–60 Hz
• 208–240 V, 50–60 Hz
• 277 V, 50–60 Hz
In Canada, use factory-installed photocell only.
Stainless Steel Wire Guard

Certified For IEC Zone 2 (Ex nR) (UL Classified to the
IEC Standard) ....................................................................... S826TB
Furnished with:
• 4 mm2, 3-point terminal block
• Crimp internal wiring connections
• P55 guard
V2PC Photocell—Factory Installed
• 120 V, 50–60 Hz................................................................. /V2PC20
• 208–240 V, 50–60 Hz ......................................................... /V2PC22
• 277 V, 50–60 Hz................................................................. /V2PC27
Optional Voltage Ballasts for HID Luminaires
• 220 V, 50 Hz....................................................................... /220 50
• 220 V, 60 Hz....................................................................... /220 60
• 240 V, 50 Hz....................................................................... /240 50
Optional Voltage Ballasts for Fluorescent Luminaires
(Consult Factory)
• 125 V DC............................................................................ /125 VDC
• 12 V DC.............................................................................. /12 VDC
• 24 V DC.............................................................................. /24 VDC
Isolated Ballast for HID Luminaires
(Consult Factory)
• 208 V, 60 Hz....................................................................... /208CWI
• 240 V, 60 Hz....................................................................... /240CWI
• 480 V, 60 H ........................................................................ /480CWI
*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.
TEFLON is a registered trademark of E.I. duPont Co.

Dimensions (In Inches):

Note: Approximate weight less guard 28 lbs. P55 guard 0.5 lbs.

1124

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Cl. II, Groups F, G
Cl. III & Simultaneous
Presence
Marine & Wet Locations;
Enclosure Type 4X, IP66

Copyright© 2013 Eaton’s Crouse-Hinds Business

Cat. #
V2PC20
V2PC22
V2PC27
P55

1124-1125.qxp

12/16/2013

6:57 PM

Page 1125

Champ-Pak™ Wall Pack
Luminares

Photometric Data

6L

CPMV Photometric Data
Luminaire With Refractor Less Wire Guard
CPMVS2W150 Lamp: 150 W/E23-1/2 Clear High Pressure Sodium (HPS)

Luminaire With Refractor Less Wire Guard
CPMVM2W150-S828 Lamp: 150 W/ED28 Clear Pulse Start Metal Halide

6L

For additional photometric data, contact Eaton's Crouse-Hinds.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1125

1126-1127.qxp

6L

12/16/2013

6:57 PM

Page 1126

Champ-Pak™ Wall Pack
Luminares

Photometric Data

Luminaire With Refractor Less Wire Guard
CPMVF2W084 Lamps: (2) PL-T 42W/30/4P Compact Fluorescent

6L

For additional photometric data, contact Eaton's Crouse-Hinds.

1126

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1126-1127.qxp

12/16/2013

6:57 PM

Page 1127

6L

Temperature Performance Data

Champ-Pak™ Wall Pack
Luminares

Temperature Performance Data:
Simultaneous Presence
Class I/Class II
(Gas and Dust Present in the Same Area)

Class I
Division 2 and Zone 2

Ambient
Temp.°C

Watts

Standard
Product

HIGH PRESSURE SODIUM
40
T3A
55
T3A
50
65*
T3

Restricted Breathing
AEx nR/Ex nR
Option S826
Suitable for Class I,
Division 2
or Zone 2 and Class II

Supply
Wire
Temp.°C

Restricted
Breathing
AEx nR/Ex nR
Option S826

Class II and
Class III

Standard
Product
Suitable for Class I,
Division 2/Class II

T6
T6
T5

T5
T4A*
—

T3A/T5
T3/T4A*
—

T5
T4*
—

90
105
105

T3A/T5
—
—

T5
—
—

90
105
105

70

40
55
65*

T3A
T3A
T3

T6
T6
T5

T5
—
—

100

40
55*

T2C
T2C

T5
T4

Consult Factory for Class II Suitability with
105°C Supply Wire

150

40

T2B

T4

—

—

—

105

70

40
55
65*

T3C
T3C
T3C

T6
T6
T5

T5
—
—

T3C/T5
—
—

T5
—
—

90
105
105

100

40

T3

T6

—

—

—

90

150PS (S828)

40

T2D

T5

—

—

—

105

90
105

METAL HALIDE

COMPACT FLUORESCENT
26
40
T3B

T6

T6

T3B/T6

T6

75

26 (347 V)

55
40

T3A
T3

T6
T6

—
—

—
—

—
—

75
75

32

40
55

T3B
T3A

T6
T6

T6
—

T3B/T6
—

T6
—

75
75

32 (347 V)

40

T6

—

—

—

75

T3B

T6

T6

T3B/T6

T6

75

42 (347 V)

55
40

T3A
T3

T6
T6

—
—

—
—

—
—

75
75

52

40
55

T3
T3

T6
T6

T6
—

T3B/T6
—

T6
—

75
90

64

40
55

T3
T3

T6
T6

T6
—

T3/T6
—

T6
—

75
90

84

40

T2C

T6

—

—

—

90

EMERGENCY FLUORESCENT
26
40*
T3B

T6

—

—

—

75

6L

T3

42 (120–277 V) 40

INDUCTION
55

40*
55*

T2D
T2D

T6
T6

T6
—

—
—

T6
—

75
75

85

40*

T2B

T6

—

—

—

75

*Fuses (suffix S658) are not available for indicated light sources and ambient temperatures.
Note:

Luminaires requiring 105°C supply wire are furnished with 3 ft. of rated wire for external wiring connection.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1127

1128-1129.qxp

12/16/2013

6L

8:40 PM

Page 1128

UL/cUL Listed
NEMA 4X
IP66

Champ® Pro PFM Series
Luminaires
Perfect for outdoor/indoor flood
illumination

The Champ® Pro PFM
Family

Drivers:

Champ® Pro PFM Series Floodlights are
designed to provide full-spectrum, crisp,
white light. Five versions of the Champ
PFM LED are available, providing ideal
solutions for a wide range of applications.

Standard

Champ Pro
PFM Model

Equivalent
MH HID
Lamp

PFM5L
PFM7L
PFM9L
PFM11L
PFM13L

100W-150W
150W-175W
175W-250W
250W-400W
400W

®

Model

90-305 VAC, 50 / 60
Hz; 108-250 VDC
347 VAC Model
480 VAC Model

Option 1
Option 2

Standard Materials:
• Housing – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens – shatter-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals
required

Energy
Savings
Up to
62%!

Certifications and
Compliances:
•
•
•
•
•

5L - 13L

LED System:
• High brightness light emitting diode
(LED) arrays
• Color temperature: 3000K (CRI 82) and
5600K (CRI 65) options available
• Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions

UL1598
UL1598A
cUL
NEMA 4X; IP66
DesignLights Consortium® approved for
select models (refer to Ordering
Information for details)

Electrical Ratings:
PFM5L

PFM7L

PFM9L

PFM13L

100-277V 50-60 Hz

Voltage Range, VAC

6L

PFM11L

347 / 480V 60 Hz

Voltage Range, VDC

108-250

108-250

108-250

108-250

108-250

Input Power (Nom.)

64

89

121

149

179

Input Amps (Max.)

0.550

0.800

1.083

1.608

1.608

Power Factor

>0.85

>0.85

>0.85

>0.85

>0.85

Ordering Information:
Color Temperature
Cool Color Temperature

5L Series

7L Series

9L Series

11L Series

13L Series

PFM5LCY/UNV1 76 PFM7LCY/UNV1 76 PFM9LCY/UNV1 76 PFM11LCY/UNV1 76 PFM13LCY/UNV1 76
PFM5LCY/120 76*

PFM7LCY/120 76*

PFM9LCY/120 76*

PFM11LCY/120 76*

PFM13LCY/120 76*

Warm Color Temperature PFM5LWY/UNV1 76 PFM7LWY/UNV1 76 PFM9LWY/UNV1 76 PFM11LWY/UNV1 76 PFM13LWY/UNV1 76
For 347 VAC option, replace /UNV1 with /347. For 480 VAC option, replace /UNV1 with /480.
To order fixture without optics, remove ‘76’ from the end of the catalog number.
*5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard Terms and Conditions.
DesignLights Consortium approved models. Cool white only.

Options:
Description
Suffix
Fused (only applies to UNV1 model, not available for 347V or 480V; NOT marine or cUL Listed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658
Two conduit/cable glands of like thread installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S886

Accessories:
Description

Catalog No. Sold Separately

Bolt-on visor (sold separately)
Bolt-on wire guard (sold separately)
Floodlight slipfitter (sold separately)
Slipfitter wall mount adapter (sold separately)

DSV1
P61
SFA6
SWB6

1128

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1128-1129.qxp

12/16/2013

8:40 PM

Page 1129

Champ® Pro PFM Series
Luminaires

6L

UL/cUL Listed
NEMA 4X
IP66

Perfect for outdoor/indoor flood illumination

Dimensions:
[167.1]
6.6

[532.9]
21.0

[552.5]
21.75
[405.9]
16.0

[14]
Ø.55

[120.7]
4.75

Photometric Data:

Weights:
Model

Lbs.

5L
7L
9L
11L
13L

39.11
39.16
39.73
40.35
40.35

PFM13L @ 30 Ft. High; Tilt Angle = 45 Degrees
(Isofootcandles)

Ambient Temperature:
Champ® Pro PFM Model

Max. Temp. ºC

PFM5L

55

PFM7L

55

PFM9L

55
55
40

6L

PFM13L

40

6L

PFM11L

55
Point By Point FC Readings

Distance in Feet

.35 Fc

.5 Fc

1 Fc

2 Fc

2.5 Fc

MULTIPLIERS FOR OTHER LED FLOODLIGHTS
Luminaire
Series

Wattage

Lumens*

PFM5L

64

4386

PFM7L

90

6828

PFM9L

121

8478

PFM11L

188

10481

*PFM 13L output is 13,155.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1129

1130-1131.qxp

12/16/2013

6:57 PM

Page 1130

Champ® Pro PFM Series 25L
and 50L LED Floodlights

6L

UL/cUL Listed
NEMA 4X
IP66

The Champ® Pro PFM LED
Family
PFM LED Series Floodlights are designed
to provide full-spectrum, crisp, white light.
Two versions of the Champ Pro PFM LED
are available, providing ideal solutions for
a wide range of applications.

PFM
Model

Equivalent
HID Lamp

Energy
Savings

PFM25L 750W MH
PFM50L

1500W MH /
1000W HPS

Applications:

6L

PFM25L Model

Up to 65%!

PFM50L Model

• High lumen output for installation in high
mounting heights
• Locations requiring continuous and
consistent light levels
• Areas requiring frequent on-and-off of
lights
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist; indoors
or outdoors
• NEMA 4X, marine, wet locations, and
hose-down environments
• Indoor and outdoor area lighting in
plants, buildings, and parking areas
• Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; platforms;
loading docks; outdoor mounted general
area lighting
• Ball mills, stackers and reclaimers,
concentrators, smelters, mine roadways,
outdoor processing areas, truck service
shops, shovels, and drag lines

Certifications and
Compliances:

Standard Materials:
• Housing – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens – heat- and impact-resistant glass
• Yoke mount (standard) – copper-free
aluminum with Corro-free™ epoxy
powder coat
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals
required

LED System:
• High brightness light emitting diodes
(LEDs)
• Color temperature: 5000K (CRI 67)
• Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions
• LM-79, LM-80 reports available upon
request

Options:
Description
Two conduit/cable glands of
like thread installed ...................
Diffused glass lens ....................
Polycarbonate lens....................

Suffix
S886
S891
S903

Accessories:
Description

Cat. # (Sold
Separately)

Bolt-on visor
(sold separately)....................
Bolt-on wire guard
(sold separately)....................
Floodlight slipfitter
(sold separately)....................
Slipfitter wall mount adapter
(sold separately)....................

DSV1
P61
SFA6*
SWB6*

*Available with PFM25L model only.

Drivers:
PFM Model
/UNV1
/UNV34

25L, 50L
90-305 VAC, 50 / 60 Hz;
127-250 VDC
277-480 VAC Model

Electrical Ratings:

•
•
•
•
•

UL1598
UL1598A
cUL
NEMA 4X; IP66
DesignLights Consortium® approved for
select models (refer to Ordering
Information for details)
• UL approved up to 40°C ambient

PFM25L

PFM50L
120-277V 50 / 60 Hz

Voltage Range, VAC

277-480V 50 / 60 Hz

Voltage Range, VDC

127-250V

Input Power (Nom.)

263

531

Input Amps (Max.)

2.6

5.2

Power Factor

>0.90

Ordering Information:
25L Series†*

50L Series

PFM25LCY/UNV1 76
PFM50LCY/UNV1 76
NOTE: Available in cool color temperature only. For 277-480 VAC option, replace /UNV1 with /UNV34.
†DesignLights Consortium® approved model at 120-277V.
*PFM25L is DLC approved with a 5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton's Crouse-Hinds standard terms and conditions.

1130

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1130-1131.qxp

12/16/2013

6:57 PM

Page 1131

Champ® Pro PFM Series 25L
and 50L LED Floodlights

UL/cUL Listed
NEMA 4X
IP66

6L

Safe, reliable heat transfer

High efficiency and lumen output

The heat sink was designed to perform in
high ambient temperatures up to +40ºC and
as low as -25ºC. The thick walls of the
castings make for a tough, rugged housing
that keeps the internal driver and LED
temperatures down, allowing them to
perform flawlessly, and protects them from damage. Separated driver
and LED housing allows dust to shed from fixture.

High efficiency drivers and LEDs provide 100 LPW for
reliable low cost operation in industrial environments.
Components were chosen to give industry-leading
light output from an LED flood. Replaceable drivers
and LEDs for ease of maintenance and “no lights out”
feature.

6L
6L

Versatile design
Can be used for outdoor or indoor
applications, and for a wide range of
mounting heights depending on model and
light level requirement. Optics were
specifically designed to give the familiar
and industry-accepted NEMA 7x6 beam
light pattern.

www.crouse-hinds.com

Optional equipment (sold separately)
Optional visor offered to control light spill.
Optional wire guard offered to protect lens from damage.
Other options available - consult part numbering guide.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1131

1132-1133.qxp

12/16/2013

7:42 PM

Page 1132

Champ® Pro PFM Series 25L
and 50L LED Floodlights

6L

UL/cUL Listed
NEMA 4X
IP66

Dimensions:
532.9
21.0

277
10.9
234.5
9.2

552.5
21.75

203.7
8.0

405.9
16.0

525.6
20.7

120.7
4.75

.55

PFM25L Model
277
10.90

556.3
21.90

254
10.00

235.8
9.28

532.9
20.98

203.7
8.02

13.9
Ø .55

127
5.00

825
32.48

632.6
24.90

6L

PFM50L Model

Photometric Data:
Weights:

PFM50L @ 50 Ft. High

PFM25L @ 50 Ft. High
200

200

175

150

125

100

75

50

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.0

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.4

0.4

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.4

0.4

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.4

0.5

0.5

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.5

0.5

0.4

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.5

0.6

0.6

0.7

0.7

0.7

0.8

0.7

0.7

0.7

0.6

0.6

0.5

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.4

0.5

0.6

0.7

0.8

0.9

0.9

0.9

0.9

0.9

0.8

0.7

0.6

0.5

0.4

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.4

0.5

0.5

0.6

0.6

0.6

0.5

0.5

0.4

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.4

0.5

0.6

0.8

0.9

1.0

1.1

1.2

1.2

1.2

1.1

1.0

0.9

0.8

0.6

0.5

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.5

0.6

0.7

0.7

0.8

0.7

0.7

0.6

0.5

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.3

0.4

0.6

0.7

0.9

1.1

1.3

1.5

1.6

1.6

1.6

1.5

1.3

1.1

0.9

0.7

0.6

0.4

0.3

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.5

0.7

0.8

0.9

1.0

1.0

1.0

0.9

0.8

0.7

0.5

0.4

0.3

0.2

0.2

0.1

0.1

0.1

0.2

0.2

0.3

0.4

0.5

0.6

0.8

1.1

1.4

1.7

1.9

2.1

2.1

2.1

1.9

1.7

1.4

1.1

0.8

0.6

0.5

0.4

0.3

0.2

0.2

0.1

0.2

0.3

0.4

0.5

0.7

0.9

1.3

2.8

2.9

2.8

2.2

1.7

1.3

0.9

0.7

0.5

0.4

0.3

0.2

0.1

0.1

0.2

0.3

0.4

0.5

0.7

1.0

1.5

2.0

2.7

3.3

3.7

3.9

3.7

3.3

2.7

2.0

1.5

1.0

0.7

0.5

0.4

0.3

0.2

0.1

0.1

0.2

0.2

0.4

0.5

0.8

1.1

1.7

2.4

3.4

4.3

5.0

5.1

5.0

4.3

3.4

2.4

1.7

1.1

0.8

0.5

0.4

0.2

0.2

0.2

0.2

0.4

0.6

0.9

1.3

2.1

3.2

4.6

6.3

7.4

7.9

7.4

6.3

4.6

3.2

2.1

1.3

0.9

0.6

0.4

0.2

0.2

0.1

0.1

0.2

0.3

0.4

0.7

1.1

1.9

3.0

6.5

8.0

8.5

8.0

6.5

4.5

3.0

1.9

1.1

0.7

0.4

0.3

0.2

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.3

0.1

0.1

0.1

0.2

0.2

0.4

0.1

0.1

0.1

0.2

0.3

0.4

0.1

0.1

0.1

0.2

0.3

0.0

0.1

0.1

0.1

0.2

0.5

0.5

0.6

1.1

1.2

1.3

1.6

1.7

2.1

2.4

1.6

2.3

3.1

3.7

1.5

2.2

3.1

3.8

0.8

0.7

1.0

0.6

0.8

1.2

0.4

0.7

1.0

0.3

0.6

0.9

175

150

125

100

75

50

1.3

1.4

1.3

1.2

1.1

0.8

0.6

0.5

0.3

0.2

0.2

0.1

0.1

0.1

1.8

1.9

1.8

1.6

1.3

1.0

0.7

0.5

0.4

0.2

0.2

0.1

0.1

0.1

2.5

2.4

2.1

1.7

1.2

0.8

0.6

0.4

0.3

0.2

0.1

0.1

0.1

3.9

3.7

3.1

2.3

1.6

1.0

0.7

0.4

0.3

0.2

0.1

0.1

0.1

0.1

3.8

3.1

2.2

1.5

0.9

0.6

0.3

0.2

0.1

0.1

0.1

0.0

0.1

2

25

0

.1

.25

.5

1

1.5

3

4

4.1

25

0

0.25

0.15

0.5

1

1.5

Point By Point Foot-Candle Readings

-125

-100

-75

-50

-25

0

25

1.7

2.2

2

4

4.5

0.25

0.50

1.00

1.50

50

75

100

125

-125

-100

-75

-50

2.6

-25

0

25

75

50

2.00

3.00

4.00

0.15

0.25

0.50

1.00

0.2

0.1

100

125

1.50

2.00

3.00

4.00

5.00

Footcandles

Luminaire
Series

Wattage

Lumens

Luminaire
Series

Wattage

Lumens

PFM25L

263

26,240

PFM50L

531

53,890

www.crouse-hinds.com

52.00
106.00

Distance In Feet

Footcandles

1132

5

3

Lbs.

PFM25L
PFM50L

Point By Point Foot-Candle Readings

Distance In Feet

0.10

2.6

PFM Model

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1132-1133.qxp

12/16/2013

7:42 PM

Page 1133

6L

Cl. I, Div. 2
Cl. I, Zone 2

Champ® Floodlight Family
The Standard for Safety
and Reliability
Whenever Eaton's Crouse-Hinds develops a new product, system, or
procedure, we focus on one overriding question: Will it lower the
total cost of ownership for our customers?
With our new expanded line of Champ® Floodlights, the answer is
most definitely, “Yes.”
Eaton's Crouse-Hinds utilized more than 100 years of hazardous
lighting expertise to design a global floodlight line of unmatched
reliability, quality, and performance for your area lighting needs.
• Energy-efficient with optimal light output and beam distribution
• The most accessible ballast assembly in the industry
• Restricted breathing is standard on all floodlights
• Offered with both North American ballast (made to ANSI standard)
and European style IEC ballast gear (pending)
• UL marine rated, NEMA Type 4X and IP66

6L
6L

Champ FMV nR Series Floodlight

Champ F2MV Mini-Floodlight

The Champ FMV nR Series Floodlight offers exceptional indoor and
outdoor illumination in industrial areas. Because of its superior
corrosion resistance and restricted breathing being standard, the
FMV floodlight is the ideal choice for diverse industrial applications
that include wet and marine environments.
Differentiations:
• Full frame trunnion mounting bracket
• Restricted breathing standard
• 55°C and 65°C ambient air suitability
• Standard with terminal blocks
• Class I, Division 2/Zone 2
• Removable ballast tray

The F2MV is a compact floodlight that consists of a Corro-Free™
epoxy coated copper-free aluminum enclosure with stainless steel
external hardware and an impact-resistant glass lens. It is suitable
for marine and wet locations and is ideal where space constraints
restrict the use of larger floodlights.
Differentiations:
• Small, compact size
• Easy mounting installation—only 2 bolts!
• Powerful light distribution for floodlight and task applications
• Rated for use in 65°C ambient air for hazardous location
applications

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1133

1134-1135.qxp

12/16/2013

6:58 PM

Page 1134

Champ® Floodlight Family

6L

Cl. I, Div. 2
Cl. I, Zone 2

The Standard for Safety and Reliability

Champ Voyager nR™
Stainless Steel Floodlight

The Champ FMV1000 nR prides itself on offering restricted breathing
and easy-to-wire terminal blocks as standard components. It is
NEMA Type 4X and IP56 watertight and due to its heavy-duty vaportight, copper-free aluminum housing and stainless steel hardware, it
is exclusively designed for harsh and industrial areas requiring broad
area lighting. The Champ FMV1000 nR provides a robust design for
optimal use in the most corrosive/marine environments.
Differentiations:
• Hazardous location high wattage floodlight for Class I,
Division 2, Zone 2
• Restricted breathing standard
• T3 rating in Class I, Zone 2
• 40°C and 55°C ambient air suitability
• Hinged removable door
• Available in 600, 750, 1000, and 1500W systems
(1500W for non-hazardous locations only)

The Champ Voyager nR Floodlight offers the industry's coolest
temperature rating and is the only mogul-base Class I, Division 2
and Zone 2 stainless steel floodlight with restricted breathing as
standard construction. It boasts a wide, powerful beam to deliver
more light to your process, and with the standard terminal block and
removable ballast-component tray, the Champ Voyager is perfect for
outdoor, marine, corrosive, and high temperature locations.
Differentiations:
• Housing, door and external parts are all 316 stainless steel
• Restricted breathing standard with T-ratings of T3 and T4
• Pre-wired with terminal blocks for easy wiring
• Hinged door and removable ballast tray

6L

Champ FMV1000 nR
High Wattage Floodlight

Product Selector Chart
F2MV MINI

FMV nR

FMV1000 nR

Voyager nR

Hazardous

Class I, Division 2
Class I, Zone 2

•

•

•

•

Hazardous Restricted Breathing
(Ex nR)

NEC/CEC:
Class I, Division 2
Class I, Zone 2
IEC Zone 2

•

•

•

•

ATEX Certification with IEC
Ballast and Lamp Socket

IEC Zone 2
Ex nR II ATEX

pending

•

Wet

•

•

•

•

Marine

•

•

•

•

NEMA Type 4, 4X

•

•

•

•

NEMA 7x6

•

•

•

•

Corrosion Resistant

•

•

•

•

150–400
175–400

600, 750, 1000
1000, 1500

150–400
175–400

Confined Areas
Wattage

1134

•
High Pressure Sodium
Metal Halide

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

50–150
70–175

•

Copyright© 2013 Eaton’s Crouse-Hinds Business

1134-1135.qxp

12/16/2013

6:58 PM

Page 1135

Champ® FMV nR
Floodlights

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II
Cl. II, Div. 1, Groups F, G
(up to 250W)

The Champ FMV nR Series Floodlight
offers exceptional illumination in industrial
areas, both indoors and out. And, it
comes standard as a restricted breathing
luminaire. The Champ FMV nR Series
Floodlight is easily adjusted to aim light
where it’s needed and is available in a
wide variety of energy-saving mogul base
HID light sources and wattages including:
• 150–400W High Pressure Sodium
• 175–400W Metal Halide

Applications:
The FMV is made with heavy-duty, diecast aluminum components and stainless
steel hardware. It offers superior
corrosion resistance to ensure longer life,
which makes the FMV floodlight the ideal
choice for a wide variety of industrial
applications, including wet and marine
environments.

Features and Benefits:

• Heavy-duty, die-cast copper-free
aluminum enclosure with epoxy coating
and stainless steel hardware—provides
a robust design with industrial grade
construction and corrosion resistance
• Hinged door frame assembly—has
captive cover screws for ease of
relamping
• Yoke mount design—standard
construction provides the greatest
mounting flexibility, can be mounted
vertically (wall), horizontally (rooftop or
floor), or any angle in between

Certifications &
Compliances:
NEC/CEC (NEC Ballast Gear and
Socket):
• Class I, Division 2, Groups A, B, C, D
• Class I, Zone 2, AEx nR II
• Class II, Division 1, Groups F, G
(up to 250W)
• Marine locations
• NEMA Type 4X and IP66
• Wet locations
IEC (IEC Ballast Gear and Socket):
• IEC Zone 2, Ex nR II (pending)
UL/cUL Standards:
• 844—Hazardous (Divisions Classified)
Locations
• 60079-15
• 1598—Luminaires
• 1598A—Supplemental Requirements for
Luminaires for Installation on Marine
Vessels
IEC Standards:
• 60079-15

6L

The only full frame trunnion mount
floodlight with a T3 rating and a
removable ballast tray assembly.

Industry Best for Ease of
Installation:
1. Removable ballast tray
2. Prewired to terminal blocks
3. Substantial room for wiring

Ratings (Electrical/Size):
Sources/Wattages (Mogul Base
Lamps)
• HPS—150, 250, and 400W
• MH—175, 250, and 400W

Voltages

Standard Materials:
• Fixture housing and door frame
assembly—die-cast aluminum
• External hardware—stainless steel
• Lens—heat- and impact-resistant
tempered glass
• Yoke—aluminum

Standard Finishes:
• Enclosure and yoke—Corro-Free™ epoxy
powder coat
• Stainless steel—natural

www.crouse-hinds.com

Standard Voltage Ballasts
• Multi-tap (120, 208, 240, and 277V
60Hz)
• Dual-tap (120 and 277V)
• 480V 60Hz
• Tri-tap (120, 277, 347V 60Hz)
Optional Voltage Ballasts
• 220V or 240V 50Hz (for export)
• 220V 60Hz (for export)
Isolated Ballasts
• 208, 240, or 480V (for Canada)

Hub Size
• Standard—3/4" NPT
• Optional—25 mm (M25 x 1.5) or 20 mm
(M20 x 1.5)

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1135

6L

• AEx nR, Ex nR restricted breathing
rating is standard—a hazardous location
luminaire without additional accessories
or options; restricted breathing offers
cooler T-numbers for increased
hazardous locations suitability
• NEMA 7x6 butterfly beam floodlight
pattern—wide, uniform and far reaching
to provide excellent efficiency and more
light where you need it
• NEMA Type 4X and IP66 construction is
designed for use indoors and outdoors
in marine and wet locations—with
stainless steel external hardware
suitable for saltwater and corrosive
applications
• Easy wiring—standard terminal block
with marked terminals saves time and
eliminates wiring errors
• Vapor-tight sealing cable connector—
standard
• Will accommodate existing mounting
hardware—SFA6 slipfitter for pole and
SWB6 wall mount
• Optional metric machining will accept
M20 or M25 (must be specified on order)
• 40°C, 55°C and 65°C ambient
suitability—addresses high ambients
common at industrial facilities
• Low ambient capability to -40°C—
perfect for colder climates

• 3-axis resonance withstand and UL844
vibration compliant—can stand up to
the tough jobs
• Precision formed aluminum reflector—
superior beam control, distribution and
efficiency
• Multi-tap ballasts—offering a choice of
120, 208, 240 and 277V; 220V 50Hz,
240V 50Hz, Tri-Tap (120, 277 and 347),
and 480V ballasts are also available
• High light output with a low cost of
operation—cost-effectiveness in a high
wattage floodlight
• For use with SFA6 Slipfitter Adapter and
SWB6 Wall Mount Bracket
accessories—further enhances
mounting flexibility

Marine locations
NEMA Type 4X and IP66
Wet locations

1136-1137.qxp

12/16/2013

6:58 PM

Page 1136

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II

Champ® FMV nR
Floodlights

6L

Photometric Data:

Ordering Information for Floodlight with
NEC Ballast:
Lamp Type

Watts
150

Yoke Mount 3/ 4" NPT Hub
FMVSY150/MT 76

High Pressure Sodium

250

FMVSY250/MT 76

400

FMVSY400/MT 76

175

FMVMY175/MT 76

250

FMVMY250/MT 76

400

FMVMY400/MT 76

Metal Halide

Isofootcandle Chart FMV
400W High Pressure Sodium
(HPS)
Catalog Number: FMVSY400-76
Lamp: 400W Clear HPS
Lumen Rating: 50,000
For 150W HPS, multiply
footcandles by .32.
For 250W HPS, multiply
footcandles by 0.6.
Fixture located at 0°, 0°
aiming angle at 45°

Voltage Suffixes†
Voltage (60Hz)
Suffix

Dual-Tap
/DT

(Note: See Figures 1 and 2).
Tri-Tap
/TT

Multi-Tap
/MT

480
/480
Isofootcandle Chart FMV
400W Metal Halide (MH)
Catalog Number: FMVMY400-76
Lamp: 400W Clear MH
Lumen Rating: 34,000
For 250W MH, multiply
footcandles by 0.6.
Fixture located a 0°, 0°
aiming angle 45°

To complete catalog number, add voltage and options suffix(es).

Options
Example:

FMVMY400/MT 76 M25 V2PC20
Series

Yoke

Lamp
Type

Voltage

Watt

Beam
Spread

Metric
Entry

Photocell

†150W HPS fixtures are furnished with ANSI spec/S55 ballasts for 55V lamps. For 100V
lamps, add suffix "CE" after voltage suffix. Example: FMVSY150/MT CE 76.

(Note: See Figures 1 and 2).

6L

Options:

Effective Projected Area (EPA):

Description
Suffix
Instant Restrike and Ballast Guard
Instant restrike—enables a hot HPS lamp to immediately
restrike after a momentary loss of arc due to voltage
fluctuation or power outage
Ballast guard starter cut out switch—prevents starter
pulsing when lamp is cycling or inoperative; prolongs
ballast and ignitor life.
• 150W LX HPS only..............................................................
TIR
Factory assembled with HID lamp installed .........................
FA
Fused (not suitable for marine applications).........................
S658
20mm metric thread for conduit opening .............................
M20
25mm metric thread for conduit opening .............................
M25
3
/ 4" NPT hub conduit opening ............................................... NPT75
Furnished with lamps (not installed) .....................................
S714
Retention chain .....................................................................
S831
Pulse-Start Metal Halide .......................................................
S828
Enclosure machined for 2 conduit/cable entries ..................
S886

Options for Photocell*:

• For windloading
• For proper pole selection
Aiming Angle

EPA

0°
30°
45°

2.9 FT2
2.5 FT2
2.1 FT2

Footcandle Table:
Mounting
Height
15'
20'
25'
30'
35'
40'

A
8.0
4.5
2.9
2.0
1.5
1.1

Footcandle Values for Isofotcandle Lines
B
C
D
E
4.0
2.0
0.80
0.40
2.3
1.1
0.50
0.23
1.4
0.7
0.30
0.14
1.0
0.5
0.20
0.10
0.7
0.4
0.15
0.07
0.6
0.3
0.11
0.06

Description
Suffix
Photocell 120V, 50/60Hz installed ....................................... V2PC20
Photocell 208-240V, 50/60Hz installed ................................ V2PC22
Photocell 277V, 50/60Hz installed ....................................... V2PC27
*Photocell for Div. 2 installation only.

Accessories (Order Separately):
Slipfitter Adapter
To be mounted to yoke mount fixture
Fits onto 2" pipe/conduit ...............................................
Wall Bracket
Use with slipfitter adapter SFA6 for easy
wall mounting and increased adjustability.....................

1136

www.crouse-hinds.com

Marine locations
NEMA Type 4X and IP66
Wet locations

US: 1-866-764-5454

SFA6
SWB6

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1136-1137.qxp

12/16/2013

6:59 PM

Page 1137

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II

Champ® FMV nR
Floodlights

6L

Marine locations
NEMA Type 4X and IP66
Wet locations

Weights and Dimensions:
Net Fixture Weights (Lbs.):
Fixtures
150W
175–250W
400W

FMVS
37
40
44

FMVM
37
42
44

SFA6 (Slipfitter Adapter)—Add 4 lbs., SWB6 (Wall Bracket)—Add 6 lbs.

18.0 [458.0]

6.8 [173.9]

20.0 [508.0]
23.6 [600.1]

19.1 [485.8]

4.8 [120.7]

30°

30°

60°

FIGURE 2

FIGURE 1

www.crouse-hinds.com

180°

120°
90°

US: 1-866-764-5454

CAN: 1-800-265-0502

6L

90°

.6 DIA. [14.3]

90°

90°

FIGURE 3

Copyright© 2013 Eaton’s Crouse-Hinds Business

1137

1138-1139.qxp

12/16/2013

6L

7:00 PM

Page 1138

Champ® FMV nR
Floodlights

Cl. I, Div. 2, Groups A,B,C,D
Cl. I, Zone 2, AEx nR II

Marine locations
NEMA Type 4X and IP66
Wet locations

Temperature Performance Data:
40°C Ambient
Lamp
Catalog
Series

Type

Temperature Code

Watts

High
Pressure
Sodium

Temperature Code

Supply
Wire °C

Class I,
Zone 2

Class I,
Div. 2

Supply
Wire °C

Class I,
Zone 2

Class I,
Div. 2

Supply
Wire °C

T4
T4
T3
T4
T4
T3
T3
T3
T3
T4
T4
T3
T4
T4
T3
T3
T3
T3
T4
T4
T3
T4
T4
T3
T3
T3
T3

325
325
325
325
325
325
T1
T1
T1
325
325
350
325
325
350
325
325
T1
325
325
350
325
325
350
350
350
T1

90
90
90
90
90
90
90
105
105
90
90
90
90
90
90
90
105
105
90
90
90
90
90
90
105
105
105

T4
T3
T3
T4
T3
T3
T3
T3
T3
T4
T4
T3
T4
T4
T3
T3
T3
T2
T3
T3
T3
T3
T3
T3
T3
T3
T3

325
325
325
325
325
325
T1
T1
T1
325
325
350
325
325
350
325
325
T1
325
325
T1
325
325
T1
350
T1
T1

90
105
105
90
105
105
105
125
125
90
105
125
90
105
125
105
125
125
105
105
105
105
105
105
105
125
125

T3
T3
T3
T3
T3
T3
–
–
–
T3
T3
T3
T3
T3
T3
–
–
–
T3
T3
T3
T3
T3
T3
–
–
–

325
325
325
325
325
325
–
–
–
325
325
T1
325
325
T1
–
–
–
325
325
T1
325
325
T1
–
–
–

105
105
105
105
105
105
–
–
–
105
105
105
105
105
105
–
–
–
105
105
105
105
105
105
–
–
–

250

175
250*
400**
FMVM
175
PulseStart
Metal
Halide

Temperature Code

Class I,
Div. 2

400**

Metal
Halide

Fixture
Aiming

65°C Ambient

Class I,
Zone 2

150
FMVS

55°C Ambient

250*
320**
350**
400**

Range

Figure

90°
120°
180°
90°
120°
180°
90°
120°
180°
90°
120°
180°
90°
120°
180°
90°
120°
180°
90°
120°
180°
90°
120°
180°
90°
120°
180°

*Suitable for use in 65°C ambient without optional fuses.
**Suitable for use in 55°C ambient without optional fuses.

6L

Lamp Selection (Mogul Base):
Fixture

Watts
Type

Bulb

FMVSY150
FMVSY250
FMVSY400
FMVMY175
FMVMY250
FMVMY400

150
250
400
175
250
400

ED23
ED18
ED37
ED28
ED28
ED37

HPS
HPS
HPS
MH
MH
MH

/ 2 BT25
1
/ 2 or ET18
1
/ 2 BT37
or BT28
or BT28
or BT37
1

G.E.

Osram

Philips

LU150/55
LU250
LU400
MVR175/U
MVR250/U
MVR400/U

LU150/55
LU250
LU400
M175/U
M250/U
M400/U

C150S55
C250S50
C400S51
MH175/U
MH250/U
MH400/U

Photometrics are available online.

1138

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

1138-1139.qxp

12/16/2013

7:00 PM

Page 1139

Champ® FMV1000 nR
High Wattage Floodlights

Cl. I, Div. 2, Groups A, B, C, D
Marine locations
Cl. I, Zone 2, AEx nR II, Group IIC NEMA Type 4X and IP56
Wet locations

6L

The Champ FMV1000 Series High Wattage Floodlight is the best in
its class with heavy-duty vapor-tight housing designed exclusively
for harsh industrial areas requiring broad area lighting.
The FMV1000 Series Floodlight boasts restricted breathing and
easy-to-wire terminal blocks as standard. It is available in the
following HID lamp sources and wattages:
• 600, 750, 1000W High Pressure Sodium
• 1000, 1500W Metal Halide

Restricted breathing
comes standard with this
NEMA Type 4X and IP56
rated floodlight.

Applications:
The Champ FMV1000 Series is NEMA Type 4X and IP56 watertight,
and its heavy-duty welded extruded aluminum housing and stainless
steel hardware provide a robust design suitable for the most
corrosive/marine environments.

Features and Benefits:

Certifications & Compliances:
NEC/CEC (NEC Ballast Gear and Socket):
• Class I, Division 2, Groups A, B, C, D
• Class I, Zone 2, AEx nR II, Group IIC
• Marine locations
• IP56
• Wet locations
• NEMA Type 4X

• Aluminum—Corro-Free™ epoxy powder coat
• Stainless steel—natural

Ratings (Electrical/Size):
Sources/Wattages (Mogul Base Lamps)
• HPS—600, 750, and 1000W
• MH—1000W
• MH—1500W non-hazardous location rated
Standard Voltage Ballasts
• Multi-tap (120, 208, 240, and 277V 60Hz)
• 480V 60Hz
• Tri-tap (120, 277, 347V 60Hz)
Optional Voltage Ballasts
• 220V or 240V 50Hz (for export)
• 220V 60Hz (for export)
Isolated Ballasts
• 208, 240, or 480V (for Canada)

Housing—extruded aluminum
External hardware—stainless steel
Yoke—316 stainless steel
Lens—heat- and impact-resistant tempered glass
Gasketing—neoprene

www.crouse-hinds.com

Standard Finishes:

Voltages:

Standard Materials:
•
•
•
•
•

Industry Best for Ease of Installation:
1. Removable ballast tray
2. Prewired to terminal blocks
3. Substantial room for wiring

6L

• AEx nR, Ex nR restricted breathing rating is standard—a
hazardous location luminaire without additional accessories or
options; restricted breathing offers cooler T-numbers for increased
hazardous locations suitability
• NEMA 7x6 butterfly beam floodlight pattern—wide, uniform and far
reaching to provide excellent efficiency and more light where you
need it
• NEMA Type 4X and IP56 construction is designed for use indoors
and outdoors in marine and wet locations—with stainless steel
external hardware suitable for saltwater and corrosive applications
• Easy wiring—standard terminal block with marked terminals saves
time and eliminates wiring errors
• Vapor-tight sealing cable connector—standard
• Standard machining—will accept 3/4 inch NCGB or 3/4 inch Myers™
hub (Myers hub is an option). Optional metric machining will
accept M20 or M25 (must be specified on order)
• Low and high ambient capability to -40°C—perfect for colder
climates, 50°C workhorse in hot climates
• Heavy-duty, extruded copper-free aluminum enclosure with epoxy
coating and stainless steel hardware—provides a robust design
with industrial grade construction and corrosion resistance
• Precision formed aluminum reflector—superior beam control,
distribution and efficiency
• High light output with a low cost of operation—cost-effectiveness
in a high wattage floodlight

Hub Size:
• 3/4" NPT—standard
• M20 or M25—optional
• Dual entry—NPT or metric

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1139

1140-1141.qxp

12/16/2013

7:00 PM

Page 1140

Champ® FMV1000 nR
High Wattage Floodlights

6L

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II, Group IIC

Marine locations
NEMA Type 4X and IP56
Wet locations

Ordering Information for Floodlight with NEC Ballast:
Lamp Type
High Pressure Sodium
Metal Halide

Watts

Base Catalog Number*

600
750
1000
1000
1500

FMVSY600__ 76
FMVSY750__ 76
FMVSY1000__ 76
FMVMY1000__ 76
FMVMY1500__ 76

*To complete catalog number, add voltage and options suffix(es).

Voltage Suffixes:
Voltage (60Hz)

Dual-Tap

Tri-Tap

Multi-Tap

480

Suffix

/DT

/TT

/MT

/480

Options
Example:

FMVS Y1000/MT 76 M25 S828
Series

Yoke

Lamp
Type

Voltage

Metric Pulse-start
Entry Metal Halide
Only
Beam
Spread

Watt

Temperature Performance Data:
40°C Ambient
Lamp

75°
30°

Fixture
Aiming

50°C Ambient

Temperature Code

Temperature Code

45°

Catalog
Series
FMVS
Figure 1
90°
30°
60°

6L

FMVM

Type

Wattage

Class I,
Zone 2

Class I,
Div. 2

Supply
Wire °C

Class I,
Zone 2

Class I,
Div. 2

Supply
Wire °C

Range

Figure

High
Pressure
Sodium
Metal
Halide
PulseStart
Metal
Halide

600
750
1000

T3
T3
T3

T1
T1
T1

90
90
90

TS
T3
T3

T1
T1
T1

105
105
105

90°
90°
90°

2
2
2

1000

T3

T1

90

T3

T1

105

90°

2

750
750
1000
1000

T3
T3
T3
T3

T1
T1
T1
T1

90
90
90
90

T3
–
T3
–

T1
–
T1
–

105
–
105
–

75°
90°
75°
90°

1
2
1
2

Accessories (Order Separately):
Slipfitter adapter: To be mounted to yoke mount fixture; fits onto 2" pipe/conduit.......................................
SFA6
Wall bracket: Use with slipfitter adapter SFA6 for easy wall mounting and increased adjustability...............
SWB6
Photocell in DS cover for use with FS/FD box:
120V, 50/60Hz.................................................................................................................................................
D2S20
208-277, 50/60Hz............................................................................................................................................ D2S208 277

Options:

540
21.3

Description
Suffix
20mm metric thread for conduit opening........................... M20
25mm metric thread for conduit opening........................... M25
3
/4" NPT hub conduit opening............................................. NPT75
Pulse-start metal halide only.............................................. S828
Retention chain................................................................... S831
Enclosure machined for 2 conduit/cable entries................ S886
FA
Factory assembled, lamp installed in lampholder..............

557.5
21.9

30.1

Weights and Dimensions:
Net Fixture Weights (Lbs.):
Fixture Series
FMVSY600
FMVSY750
FMVSY1000
FMVMY1000
FMVMY1500

1140

www.crouse-hinds.com

78
76
83
76
84

US: 1-866-764-5454

CAN: 1-800-265-0502

13.5
Ø .5
MTG HOLES

Copyright© 2013 Eaton’s Crouse-Hinds Business

120.7
4.8

279.2
11.0

1140-1141.qxp

12/16/2013

7:00 PM

Page 1141

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II, Group IIC

Champ® FMV1000 nR
High Wattage Floodlights

Marine locations
NEMA Type 4X and IP56
Wet locations

6L

Effective Projected Area (EPA):
• For windloading
• For proper pole selection
Aiming Angle

EPA

0°
30°
60°

3.5 FT2
3.6 FT2
2.9 FT2

Photometric Data:
ISO Footcandle Chart FMV
1000W High Pressure Sodium (HPS)
Catalog Number: FMVSY1000-76
Lamp: 1000W Clear HPS
Lumen Rating: 140,000
Fixture located at 0°, 0° aiming angle at 45°
(Note: See Figures 1 and 2).

ISO Footcandle Chart FMV
1000W Metal Halide (MH)
Catalog Number: FMVMY1000-76
Lamp: 1000W Clear MH
Lumen Rating: 110,000
For 1500W MH, multiply footcandles by 1.4
Fixture located a 0°, 0° aiming angle at 45°
(Note: See Figures 1 and 2).

6L

Footcandle Table for FMVS1000W:
Footcandle Values for Isofootcandle Lines
Mounting Height

A

B

C

D

E

20'
25'
30'
35'
40'

12.6
8.1
5.6
4.2
3.1

6.4
3.9
2.8
2.1
1.6

3.1
2.0
1.4
1.0
0.8

1.4
0.8
0.6
0.42
0.32

0.64
0.4
2.8
0.2
0.17

Lamp Selection (Mogul Base):
Fixture
FMVSY600
FMVSY750
FMVSY1000
FMVMY750
FMVMY1000
FMVMY1500

Watts Type

Bulb

G.E.

Osram

Philips

600 HPS
750 HPS
1000 HPS
750 MH
1000 MH
1500 MH

T15
ED37
E25
ED37
BT56
BT56

LU600/T
LU750
LU1000
MVR750/VBU/PA
MVR1000/U
MVR1500/U/SPORTS

—
—
—
—
—
—

C600S106
—
C1000S52/ED37
—
MH1000/U
MH1500/U

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1141

1142-1143.qxp

6L

12/16/2013

7:00 PM

Page 1142

Champ® Voyager nR™
Stainless Steel Floodlight

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II, Group IIC
IEC Zone 2, Ex nR II ATEX

Marine locations
Wet locations

Eaton's Crouse-Hinds Champ® Voyager nR™ Stainless Steel
Floodlight offers the industry’s coolest temperature ratings—so it can
operate below the ignition temperature of vapors and gases in your
classified area. The Champ Voyager nR Floodlight boasts a wide,
powerful beam to deliver more light to your process or pathway.
Standard terminal blocks and a removable ballast component tray
bring you the best combination of easy wiring and simple
maintenance in one rugged package.

Applications:
This unique combination of features makes the Champ Voyager nR
Floodlight ideal for outdoor, marine, corrosive, and high temperature
locations.
And because the Champ Voyager nR Floodlight meets international
standards, you can install it anywhere in the world.

Features and Benefits:
• AEx nR, Ex nR restricted breathing rating is standard—a hazardous
location luminaire with excellent T3 and T4 ratings without
additional accessories or options
• NEMA 7x6 "butterfly beam" floodlight pattern—wide, uniform and
far reaching to reduce the number of luminaires you need,
providing excellent luminaire efficiency—more light where you
need it
• Easy wiring—standard terminal block with marked terminals saves
time and eliminates wiring errors
• Removable ballast component tray—for capacitor, igniter and
terminal block to simplify maintenance and save money
• Housing, hinges, door frame and mounting yoke are all 316
stainless steel for marine and wet locations—robust construction
suitable for saltwater and corrosive applications

Now available with IEC gear and certified
to the IECEx/ATEX Directive.
The only mogul base Class I, Division 2
and Zone 2 stainless steel floodlight with
restricted breathing (vapor-tight design)
as standard construction.

6L

Certifications & Compliances:
NEC/CEC (NEC Ballast Gear and Socket):
• Class I, Division 2, Groups A, B, C, D
• Class I, Zone 2, AEx nR II, Group IIC
• NEMA Type 4X and IP66
IEC (IEC Ballast Gear and Socket):
• IEC Zone 2, Ex nR II ATEX
UL/cUL Standards:
• 844—Hazardous (Divisions Classified) Locations
• 1598—Luminaires Marine Locations
• 1598A—Supplemental Requirements for Luminaires for Installation
on Marine Vessels

Standard Materials:
•
•
•
•
•
•

Enclosure (housing and lens frame)—316 stainless steel
Lens—heat- and impact-resistant tempered glass
Gaskets—silicone rubber
Yoke and yoke bracket—316 stainless steel
Reflector—formed specular (dimpled glossy surface) aluminum
Cable gland cord grip and locknut—polyamide 6, neoprene
bushing

Standard Finishes:
• 316 stainless steel—natural

Photometrics are available online.

Industry Best for Ease of Installation:
1. Removable ballast tray
2. Prewired to terminal blocks
3. Substantial room for wiring

Ratings (Electrical/Size):
Sources/Wattages (Mogul Base Lamps)
• High Pressure Sodium (HPS) 150, 250, and 400W
• Metal Halide (MH) 175, 250, and 400W

Voltages:
Standard Voltage Ballasts
• Multi-tap (120, 208, 240, and 277V 60Hz)
• 480V, 60Hz
• Tri-tap (120, 277, 347V 60Hz)
Optional Voltage Ballasts (for export)
• 220V or 240V, 50Hz
• 220V, 60Hz
Isolated Ballasts
• 208, 240, or 480V (for Canada)

Hub Size:
• Standard: 3/ 4" NPT with a 3/ 4" gland sealing connector
1142

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1142-1143.qxp

12/16/2013

7:00 PM

Page 1143

Champ® Voyager nR™
Stainless Steel Floodlight

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II, Group IIC
IEC Zone 2, Ex nR II ATEX

Ordering Information for Floodlight
with IEC Ballast:
Lamp Type

IEC Ref.

HPS

HSE/HST

MH

HIE

6L

Marine locations
Wet locations

Ordering Information for Floodlight
with NEC Ballast:

Watts

Catalog Number*

150
250
400
150
250
400

NSSFMVSY150/220
NSSFMVSY250/220
NSSFMVSY400/220
NSSFMVMY150/220
NSSFMVMY250/220
NSSFMVMY400/220

Lamp Type

Watts

Catalog Number*

High
Pressure
Sodium

150
250
400
175
250
400

SSFMVSY150__ 76
SSFMVSY250__ 76
SSFMVSY400__ 76
SSFMVMY175__ 76
SSFMVMY250__ 76
SSFMVMY400__ 76

Metal
Halide

Voltage Suffixes:

*Uses IEC lamp socket E40.

Voltage

NSSFMV Floodlights are designed with IEC ballast gear and lamp socket, providing
certification to the IEC Ex ATEX Directive.

Tri-Tap
(120, 277,
347V, 60Hz)
Multi-Tap
120, 208, 240,
277V, 60Hz)
480V, 60Hz
240V, 60Hz

Suffix

Voltage

Suffix

/TT

220 50Hz

/220 50

/MT

220 60Hz

/220

/480
/MV

240 50Hz
240 60Hz

/240 50
/240 60

*To complete catalog number, add voltage and options suffix(es)
Example: SSFMVSY150/MT 76.

Temperature Performance Data:
55°C Ambient

40°C Ambient
Lamp
Catalog
Series

Temperature Code

Fixture
Aiming

Temperature Code

Type

Watts

Class I,
Zone 2

Class I,
Div. 2

Supply
Wire °C

Class I,
Zone 2

Class I,
Div. 2

Supply
Wire °C

Range

Figure

SSFMVS

High
Pressure
Sodium

SSFMVM

Metal Halide

150**
250**
400
175**
250**
400

T4
T4
T3
T3
T3
T3

T2B
350
T1
T2
325
325

90
90
90
90
90
105

T4
T3
–
T3
T3
–

T2B
350
–
T2
325
–

105
105
–
105
105
–

120°
90°
90°
120°
90°
90°

2
1
1
2
1
1

**Suitable for use in 55°C ambient without optional fuses.
For U.S. market, use MH Pulse Start option.

6L

Accessories (Order Separately):
Stainless steel slipfitter adapter...........................................
SFA6 SS
Stainless steel wall mount bracket.......................................
SWB6 SS
Standard slipfitter adapter
SFA6
(cast aluminum)..................................................................
Standard wall mount bracket
SWB6
(cast aluminum)..................................................................
Photocell in DS cover for use with FS/FD box:
120V, 50/60Hz....................................................................
D2S20
208-277V, 50/60Hz............................................................ D2S208 277
FIGURE 1

FIGURE 2

Photometrics are available online.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1143

1144-1145.qxp

12/16/2013

6L

7:01 PM

Page 1144

Champ® Voyager nR™
Stainless Steel Floodlight

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II, Group IIC
IEC Zone 2, Ex nR II ATEX

Marine locations
Wet locations

Effective Projected Area (EPA):
• For windloading
• For proper pole selection
Aiming Angle

EPA

0°
30°
60°

2.15 FT2
1.86 FT2
1.07 FT2

Weights and Dimensions:
Net Fixture Weights (Lbs.)
Luminaire
150W
175W
250W
400W

HPS
39
39
43
45

MH
39
39
41
43

[1.77”]
(45mm)

6L

Options:
Description
Suffix
Instant Restrike and Ballast Guard
Instant Restrike—enables a hot HPS lamp to immediately restrike after a momentary
loss of arc due to voltage fluctuation or power outage
Ballast guard starter cut out switch—prevents starter pulsing when lamp is cycling
or inoperative; prolongs ballast and ignitor life.............................................................................................................................................
TIR
• 150W LX HPS only
Factory assembled with HID lamp installed..................................................................................................................................................
FA
Fused (not suitable for marine applications).................................................................................................................................................. S658
20mm metric thread for conduit opening......................................................................................................................................................
M20
25mm metric thread for conduit opening......................................................................................................................................................
M25
3
/4" NPT hub conduit opening........................................................................................................................................................................ NPT75
Furnished with lamps (not installed)..............................................................................................................................................................
S714
Pulse-start metal halide only.........................................................................................................................................................................
S828
Enclosure machined for 2 conduit/cable entries........................................................................................................................................... S886
Yoke mount and slipfitter............................................................................................................................................................................... SFA6

Photometrics are available online.

1144

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1144-1145.qxp

12/16/2013

7:01 PM

Page 1145

Champ® Voyager nR™
Stainless Steel Floodlight

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, AEx nR II, Group IIC
IEC Zone 2, Ex nR II ATEX

6L

Marine locations
Wet locations

Photometric Data:
MH Wide Beam Reflector

HPS Wide Beam Reflector

ISOFOOTCANDLE CHART
400W Metal Halide (MH)
Catalog Number: SSFMVMY400/MT
Lamp: 400W Clear MH
Lumen Rating: 34,000
Luminaire located at 0, 0° aiming angle at 45° down from
horizontal
For 175W MH, multiply footcandles by 0.42.
For 250W HPS, multiply footcandles by 0.65.

ISOFOOTCANDLE CHART
400W High Pressure Sodium (HPS)
Catalog Number: SSFMVSY400/MT
Lamp: 400W Clear HPS
Lumen Rating: 50,000
Luminaire located at 0, 0° aiming angle at 45° down from
horizontal
For 150W HPS, multiply footcandles by 0.32.
For 250W HPS, multiply footcandles by 0.57.

Footcandle Values for Isofootcandle Lines
A
B

C

D

E

F

10'
15'
20'
25'
30'
35'
40'

20.000
8.889
5.000
3.200
2.222
1.633
1.250

4.000
1.778
1.000
0.640
0.444
0.327
0.250

2.000
0.889
0.500
0.320
0.222
0.163
0.125

0.800
0.356
0.200
0.128
0.089
0.065
0.050

0.400
0.178
0.100
0.064
0.044
0.033
0.025

Mounting
Height

10'
15'
20'
25'
30'
35'
40'

39.000
3.555
2.000
1.280
0.889
0.653
0.500

6L

Mounting
Height

Footcandle Values for Isofootcandle Lines
A

B

C

D

E

F

40.000
17.778
10.000
6.400
4.444
3.265
2.500

20.000
8.889
5.000
3.200
2.222
1.633
1.250

8.000
3.555
2.000
1.280
0.889
0.653
0.500

4.000
1.778
1.000
0.640
0.444
0.327
0.250

2.000
0.889
0.500
0.320
0.222
0.163
0.125

0.800
0.356
0.200
0.128
0.089
0.065
0.050

Photometrics are available online.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1145

1146-1147.qxp

12/16/2013

6L

7:01 PM

Page 1146

Champ® FMV LED Series
Floodlight Fixtures

• “No lights out” feature – if a single LED
fails, others will remain lit from other
drivers – minimum 50% output maintained
• Terminals – 3 x 6 sq. mm. for IEC version

The Champ FMV
LED Family
FMV LED Series Floodlights are designed
to provide full-spectrum, crisp, white light.
Five versions of the Champ FMV LED are
available, providing ideal solutions for a
wide range of applications.
FMV
Model

Equivalent MH
HID Lamp

Energy
Savings

FMV
FMV
FMV
FMV
FMV

100W-150W
150W-175W
175W-250W
250W-400W
400W

Up to
62%!

5L
7L
9L
11L
13L

Reduce operation and
maintenance costs
• Easy installation - compact modular fixture
attaches onto existing SFA6 and SWB6
• Energy-efficient technology – use up to 1/ 2
the power of standard HID luminaires
• Provides up to 60,000 hours rated life –
eliminates need for frequent lamp
replacement
• Contains no mercury or other hazardous
substances

Applications:

6L

• Five lumen outputs allow for installation
in numerous mounting heights
• Locations requiring continuous and
consistent light levels in extreme
ambient temperatures
• Areas requiring frequent on-and-off of
lights
• Where flammable vapors, gases,
ignitable dusts, fibers or flyings are
present; indoors or outdoors
• Where extremely corrosive, wet, dusty,
hot and/or cold conditions exist
• Type 4X, marine, wet locations, and
hose-down environments
• Indoor and outdoor area lighting in
plants, buildings, and parking areas
• Manufacturing plants; heavy industrial,
chemical, petrochemical or
pharmaceutical facilities; platforms;
loading docks; outdoor mounted general
area lighting

Drivers:
Model

5L - 13L
90-305 VAC, 50 / 60 Hz;
108-250 VDC
347 VAC Model
480 VAC Model

Standard
Option 1
Option 2

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

Champ FMV LED Benefits:
Enhance safety and productivity
• Instant illumination and restrike
• Better visibility with crisp, white light
• Minimum T4 temperature rating – safely
operate in the most hazardous
environments and any non-hazardous
location
• Cold temperature operation / no warm-up
required

Electrical Ratings:

Reliable performance in any
environment
• Shock- and vibration-resistant solid-state
luminaires have no filaments or glass
components that could break – greatly
reduces the risk of premature failure
• Operating ambient -40°C to 55°C
• Dark sky friendly with optional visor

Certifications and
Compliances:
• DesignLights Consortium® approved for
select models (refer to Ordering Information
for details)
NEC and CEC
• Class I, Division 2, Groups A, B, C, D
• Class I, Zone 2
• Class II, Groups E, F, G
• Class III
• Simultaneous Presence
• Wet Locations, Type 4X, IP66
UL Standards
• UL844
• UL1598 Luminaires, UL1598A Marine
CSA Standard
• CSA C22.2 No. 137
IECEx/ATEX
• IECEx UL 11.0054X
• Ex nA nR IIC T4 Gc Tamb -30°C to +55°C
• Ex nA nR IIC T5 Gc Tamb -30°C to +40°C
• Ex tc IIIC T68°C Dc IP66 Tamb -30°C to 40°C
• DEMKO 12 ATEX 115535X
• Ex II 3 G Ex nA nR IIC T4 Gc Tamb -30°C to
+55°C
• Ex II 3 G Ex nA nR IIC T5 Gc Tamb -30°C to
+40°C
• Ex II 3 D Ex tc IIIC T68°C Dc IP66 Tamb
-30°C to +40°C
• CEPEL Ex-1956/10

FMV 5L

FMV 7L

Standard Materials:
• Housing – copper-free aluminum with
Corro-free™ epoxy powder coat
• Lens – shatter-resistant glass
• Gaskets – silicone
• External hardware – stainless steel
• Factory-sealed, no external seals
required

LED System:
• High brightness light emitting diode
(LED) arrays
• Color temperature: 3000K (CRI 82) and
5600K (CRI 65) options available
• Advanced heat sink design ensures LED
does not exceed manufacturer’s
temperature ratings across all specified
ambient conditions
• LM-80 reports available upon request

Options:
Description
Suffix
Fused (only applies to
UNV1 model, not available
for 347V or 480V;
NOT marine or cUL Listed)
(NEC version only) . . . . . . . . . . . S658
Two conduit/cable glands of
like thread installed . . . . . . . . . . S886

Accessories (Order
Separately):
Description
Bolt-on visor
(sold separately) . . . . . . . . . . . .
Bolt-on wire guard
(sold separately) . . . . . . . . . . . .
Floodlight slipfitter
(sold separately) . . . . . . . . . . . .
Slipfitter wall mount adapter
(sold separately) . . . . . . . . . . . .

FMV 9L

FMV 11L

FMV 13L

100-277V 50 / 60 Hz

Voltage Range, VAC

347 / 480V 60 Hz

Voltage Range, VDC

108-250

108-250

108-250

108-250

108-250

Input Power (Nom.)

64

89

121

149

179

Input Amps (Max.)

0.550

0.800

1.083

1.608

1.608

Power Factor

>0.85

>0.85

>0.85

>0.85

>0.85

1146

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Cat. No.
DSV1
P61
SFA6
SWB6

1146-1147.qxp

12/16/2013

7:01 PM

Page 1147

Champ® FMV LED Series
Floodlight Fixtures

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

Safe, reliable heat transfer

Installation and replacement made simple

The heat sink was designed to perform in
high ambient temperatures up to +55ºC and
as low as -40ºC. The thick walls of the
castings make for a tough, rugged housing
that keeps the internal driver and LED
temperatures down, allowing them to
perform flawlessly, and protects them from damage. Separated driver
and LED housing allows dust to shed from fixture.

The full-frame yoke was designed to utilize the SFA6 slipfitter
and SWB6 wall mount bracket (sold separately), making it
ideal for retrofit or new installations. The modular design of
the FMV LED allows for easy driver or LED replacement, and
allows for the addition of the optional visor or guard in the
field. Single cable gland provided with a second plugged
cable entry, if an additional cable gland is needed.

6L

High efficiency and lumen output
High efficiency drivers and LED arrays provide
reliable low cost operation in harsh and
hazardous environments. Components were
chosen to give industry-leading light output from
an LED flood. Replaceable drivers and LEDs for
ease of maintenance and “no lights out” feature.

6L

Versatile design
Suitable for hazardous location use in gas
or dust areas. Can be used for outdoor or
indoor applications, and for a wide range of
mounting heights depending on model and
light level requirement. Optics were
specifically designed to give the familiar
and industry-accepted butterfly beam light
pattern.

www.crouse-hinds.com

Optional equipment
Cool (C) and Warm (W) white color temperatures available.
Optional visor offered (sold separately) to control light spill.
Optional wire guard offered (sold separately) to protect lens from damage.
Other options available - consult part numbering guide.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1147

1148-1149.qxp

12/16/2013

6L

7:43 PM

Page 1148

Champ® FMV LED Series
Floodlight Fixtures

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

Catalog Numbering System:
SERIES

LIGHT
SOURCE

COLOR

MOUNT

VOLTAGE

OPTICAL
DISTRIBUTION

SUFFIXES

FMV

9L

C

Y

/UNV1

76

S658

SERIES
FMV
NFMV

NEC version with Class/Division ratings
IEC version with Class/Zone ratings

LIGHT SOURCE / INTENSITY
5L
7L
9L
11L
13L

100W - 150W equivalent
150W - 175W equivalent
175W - 250W equivalent
250W - 400W equivalent
400W equivalent

COLOR TEMPERATURE
C
W

5600K (cool white)
3000K (warm white)

MOUNT
Y

Yoke

VOLTAGE
/UNV1
/120
/347
/480

100 VAC to 277 VAC 50/60 Hz, 108 VDC to 250 VDC
120 VAC 50/60 Hz**
347 VAC 60 Hz
480 VAC 60 Hz

OPTICAL DISTRIBUTION
76

Floodlight pattern optics included

ADDITIONAL ITEMS (SOLD SEPARATELY)

6L

SUFFIXES
M20
M25
S658
S886

DSV1
P61
SFA6
SWB6

20mm metric threads for conduit opening (NFMV only)*
25mm metric threads for conduit opening (NFMV only)*
Fused; for UNV1 only; not for marine or cUL
Two conduit/cable glands of like thread installed

DSV dark sky visor
Wire guard factory installed
Floodlight slipfitter
Slipfitter wall mount adapter

*Required for NFMV. Please specify conduit entry.
**5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Eaton’s Crouse-Hinds standard Terms and Conditions.
DesignLights Consortium® approved models. Cool white only.

Dimensions:
[532.9]
21.0

[167.1]
6.6

[552.5]
21.75

[405.9]
16.0

[120.7]
4.75
1148

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

[14]
Ø.55

1148-1149.qxp

12/16/2013

7:43 PM

Page 1149

Champ® FMV LED Series
Floodlight Fixtures

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2
Cl. II, Groups E, F, G
Cl. III

UL Listed & CSA Certified
IECEx / ATEX
Simultaneous Presence
Wet Location, Type 4X, IP66

6L

Photometric Data:
FMV 13L @ 40 Ft. High; Tilt Angle = 45 Degrees
(Isofootcandles)

Point By Point FC Readings

Distance in Feet

.35 Fc

.5 Fc

1 Fc

2 Fc

2.5 Fc

MULTIPLIERS FOR OTHER LED FLOODLIGHTS
Luminaire
Series

Wattage

Lumens*

FMV 5L

64

4386

FMV 7L

89

6720

FMV 9L

121

8478

FMV 11L

149

10420

*FMV 13L output is 12,940.

6L

Weights:
Model

Lbs.

Kg.

5L
7L
9L
11L
13L

39.11
39.16
39.73
40.35
40.35

17.74
17.76
18.02
18.30
18.30

Ambient Temperature:
FMV 5L
FMV 7L
FMV 9L
FMV 11L
FMV 13L

Max. Temp. ºC

Cl. I, Div. 2

Cl. I, Zone 2

Simu. Presence Div. 1 and Div. 2

Cl. II, Div. 1

Cl. III

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

40

T3C

T5

T3A

T5

T5

55

T3C

T4

-

-

-

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1149

1150-1151.qxp

12/16/2013

6L

7:01 PM

Page 1150

Champ® F2MV
Mini-Floodlights

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC

Marine locations
NEMA Type 4X
Wet locations

F2MV is a compact floodlight consisting of a Corro-Free™ epoxy
coated copper-free aluminum enclosure, with stainless steel external
hardware and impact-resistant glass. It is available for use with the
following energy-saving mogul base HID lamp types and wattages:
• High Pressure Sodium (HPS)—50, 70, 100, and 150W
• Metal Halide (MH)—70, 100, and 175W

Applications:
Available in a variety of voltage ratings, this compact floodlight is
suitable for marine and wet locations.

6L

Features and Benefits:
• Small, compact size—easy to install and maintain
• 40°C, 55°C, and 65°C ambient suitability—addresses high
ambients common in industrial facilities
• Low ambient capability to –40°C—perfect for colder climates
• Heavy-duty, copper-free aluminum enclosure with epoxy coating
and stainless steel hardware—provides a robust design with
industrial grade construction and corrosion resistance
• Continuous silicone gasketing—ensures wet and marine locations
integrity
• Stainless steel tether chain and captive cover screws—secure
cover to housing ensures ease of maintenance
• Trunnion (yoke) mount design—standard construction provides the
greatest mounting flexibility, can be mounted vertically (wall),
horizontally (rooftop or floor), or any angle in between
• Requires only two bolts to mount—simplifies installation
• Heat- and impact-resistant tempered glass lens—provides
exceptional stability
• Shock-absorbing mogul base lamp socket—cushions lamp,
improves lamp life in harsh environments
• 3-axis resonance withstand and UL844 vibration compliant—
stands up to the tough jobs
• Precision formed aluminum reflector—superior beam control,
distribution and efficiency
• NEMA 7x6 floodlight pattern with lamp orientation base down—the
ideal light distribution for industrial applications
• Multi-tap ballasts—offering a choice of 120, 208, 240, and 277V;
220V, 50Hz; 240V 50Hz; Tri-Tap (120, 277, and 347) and 480V
ballasts are also available
• High light output with a low cost of operation—a cost-effective,
high wattage floodlight
• For use with SFA6 slipfitter adapter and SWB6 wall mount bracket
accessories—further enhances mounting flexibility
• Restricted breathing compliance—cooler T-numbers for increased
hazardous locations suitability

Standard Materials:
•
•
•
•
•
•

Enclosure (housing and lens cover)—copper-free aluminum
Cover chain and external hardware—stainless steel
Lens—heat- and impact-resistant glass
Gaskets—silicone rubber
Yoke—copper-free aluminum
Reflector—diffused aluminum lighting sheet

Certifications & Compliances:
NEC/CEC:
• Class I, Division 2, Groups A, B, C, D
• Marine locations
• NEMA Type 4X
• Wet locations
IEC/NEC/CEC:
• Class I, Zone 2, Group IIC
• With suffix—S826 and S826TB—restricted breathing (Ex nR)
option
• Class I, Zone 2
• Class I, Division 2
UL Standards:
• 844—Hazardous (Divisions Classified) Locations
• 2279—Hazardous (Zones Classified) Locations
• 1572—Ordinary and Wet Locations, Marine Outside Type
CSA Standards:
• C22.2 No. 137
• CAN/CSA-E79 Series
IEC Standards:
• 60079-15

Ratings (Electrical/Size):
Sources/Wattages (Mogul Base Lamps)
• HPS—50, 70, 100, and 150W
• MH—70, 100, and 175W

Voltages:
Standard Voltage Ballasts
• Multi-tap (120, 208, 240, and 277V 60Hz)
• Dual-tap (120, 277V 60Hz)—50W HPS only
• 480V 60Hz
• Tri-tap (120, 277, 347V 60Hz)
Optional Voltage Ballasts (Consult Eaton's Crouse-Hinds)
• 220V or 240V 50Hz (for export)
• 220V 60Hz (for export)
Isolated Ballasts (Consult Eaton's Crouse-Hinds)
• 208, 240, or 480V (for Canada)

Standard Finishes:
• Enclosure and yoke—Corro-Free™ epoxy powder coat
• Stainless steel—natural

1150

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Hub Size:
• Standard—(2) 3/4" NPT
• Optional—(2) 25 mm (M25 x 1.5) or (2) 20 mm (M20 x 1.5)

Copyright© 2013 Eaton’s Crouse-Hinds Business

1150-1151.qxp

12/16/2013

7:01 PM

Page 1151

Champ® F2MV
Mini-Floodlights

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC

Marine locations
NEMA Type 4X
Wet locations

6L

Ordering Information:
Base Catalog Number*
Lamp Type
High
Pressure
Sodium
Metal
Halide

Watts

3

/4" NPT Hub

25mm Hub†

50
70
100
150
70
100
175

F2MVSY050__
F2MVSY070__
F2MVSY100__
F2MVSY150__
F2MVMY070__
F2MVMY100__
F2MVMY175__

F2MVS25Y050__
F2MVS25Y070__
F2MVS25Y100__
F2MVS25Y150__
F2MVM25Y070__
F2MVM25Y100__
F2MVM25Y175__

* To complete catalog number, add voltage and options suffix(es).
†For 20mm metric threads, change 25 to 20 in catalog number. Example: F2MVS20Y050/MT.

Voltage Suffixes:
Voltage
(60Hz)

Dual-Tap

Tri-Tap

Multi-Tap

480

Suffix

/DT

/TT

/MT

/480

Options

F2MVSY070/MT V2PC20

Example:

Series

Yoke
Lamp
Type

Voltage

Watt

Photocell

Options:

Photometrics are available online.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1151

6L

Description
Suffix
Instant Restrike and Ballast Guard
Instant Restrike—enables a hot HPS lamp to immediately restrike after a momentary loss
of arc due to voltage fluctuation or power outage
Ballast guard starter cut out switch—prevents starter pulsing when lamp is cycling
or inoperative; prolongs ballast and ignitor life
TIR
• 150W LX HPS only...................................................................................................................................................................................
Factory assembled with HID lamp installed................................................................................................................................................
FA
Fused (not suitable for marine applications)................................................................................................................................................
S658
Furnished with lamps (not installed)............................................................................................................................................................
S714
Pulse-start metal halide only.......................................................................................................................................................................
S828
Photocell 120V, 50/60Hz installed............................................................................................................................................................... V2PC20
Photocell 208-240V, 50/60Hz installed........................................................................................................................................................ V2PC22
Photocell 277V, 50/60Hz installed............................................................................................................................................................... V2PC27

1152-1153.qxp

12/16/2013

6L

7:01 PM

Page 1152

Champ® F2MV
Mini-Floodlights

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC

Marine locations
NEMA Type 4X
Wet locations

Photometric Data:
Isofootcandle Chart F2MV
150W High Pressure Sodium (HPS)
Catalog Number: F2MVSY150
Lamp: 150W Clear HPS
Lumen Rating: 16,000
For 100W HPS, multiply footcandles by .55.
For 70W HPS, multiply footcandles by .40.
For 50W HPS, multiply footcandles by .24.
Isofootcandle Chart F2MV
175W Metal Halide (MH)
Catalog Number: F2MVMY175
Lamp: 175W Clear MH
Lumen Rating: 14,000
For 100W MH, multiply footcandles by .58.
For 70W MH, multiply footcandles by .37.

Accessories (Order Separately):
Slipfitter adapter
To be mounted to yoke mount fixture
Fits onto 2" pipe/conduit..........................................................................
Wall bracket
Use with slipfitter adapter
SFA6 for easy wall mounting and increased adjustability........................

SFA6
SWB6

Effective Projected Area (EPA):
• For windloading
• For proper pole selection
Aiming Angle

EPA

0°
30°
60°

1.6 FT2
1.6 FT2
1.1 FT2

6L

Footcandle Table:
Footcandle Values for Isofootcandle Lines

Mounting
Height
10'
15'
20'
25'
30'

A

B

C

D

E

8.00
3.56
2.00
1.28
0.89

4.00
1.78
1.00
0.64
0.44

2.00
0.89
0.50
0.32
0.22

0.80
0.36
0.20
0.13
0.09

0.40
0.18
0.10
0.06
0.04

Photometrics are available online.

1152

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1152-1153.qxp

12/16/2013

7:01 PM

Page 1153

Cl. I, Div. 2, Groups A,B,C,D
Cl. I, Zone 2, Group IIC

Champ® F2MV
Mini-Floodlights

Marine locations
NEMA Type 4X
Wet locations

6L

Temperature Performance Data:
Lamp
Catalog
Series Type

F2MVS

High
Pressure
Sodium

F2MVM

Metal
Halide

40°C Ambient

55°C Ambient

65°C Ambient

Temperature Code

Temperature Code

Temperature Code

Fixture
Aiming

Class I,
Watts Zone 2

Class I,
Div. 2

Supply
Wire °C

Class I,
Zone 2*

Class I,
Div. 2

Supply
Wire °C

Class I,
Zone 2*

Class I,
Div. 2

Supply
Wire °C

Range Figure

50
70
100
150**
70
100
175**

T3C
T3A
T2D
T2A
T3C
T2D
T2A

75
60
75
75
75
75
75

T6
T5
T4
T4
T5
T4
T3

T3C
T3A
T2C
T2A
T3A
T2D
T2A

75
75
90
85
75
75
85

T3B
T3
–
T3
T4
T4
T3

T5
T4
–
T2A
T3A
T2C
T2A

75
85
–
110
85
85
110

90°
90°
90°
90°
90°
90°
90°

T6
T6
T4
T4
T6
T4
T3

1
1
1
1
1
1
1

*Restricted breathing explosion protection, requires suffix S826 (TB).
**Suitable for use in 65°C ambient without optional fuses.

Lamp Selection (Mogul Base):
Fixture

Watts Type

Bulb

F2MVSY050
F2MVSY070
F2MVSY100
F2MVSY150
F2MVMY070
F2MVMY100
F2MVMY175

50 HPS
70 HPS
100 HPS
150 HPS
70 MH
100 MH
175 MH

ED23
ED23
ED23
ED23
ED28
ED28
ED28

/2
/2
/2
1
/2
1
1
1

or
or
or
or

ET23
ET23
ET23
ET23

or BT28

/2
/2
/2
1
/2
1
1
1

G.E.

Osram

Philips

Venture

LU50
LU70
LU100
LU150/55
–
–
MVR175/C/U

LU50
LU70
LU100
LU150/55
–
–
M175/C/U

C50S68
C70S62
C100S54
C150S55
–
–
MH175/C/U

–
–
–
–
MH70W/U/ED28
MH100/U/ED28
MH175/C/U

Weights and Dimensions:
Fixture Weight: 26 lbs.

6L

Photometrics are available online.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1153

1154-1155.qxp

6L

12/16/2013

7:02 PM

Page 1154

FZD Series Floodlight Luminaire

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Zone 1
Marine Locations
Wet Locations, IP66

Finally, a true floodlight luminaire for
hazardous areas.
Eaton's Crouse-Hinds FZD Series Luminaires are the first to deliver
NEMA 7 x 6 floodlight distribution patterns for Class I, Division 1 and
Zone 1 environments. That means you’ll need fewer of them to
illuminate a given area. With their labor-saving features and flexible
mounting options, the FZD Series is ideal for:
• Heavy process industries where flammable or explosive vapors or
gases are present
• Hazardous areas, both indoors and outdoors, including those
requiring elevated ambient capability, where long life and low
maintenance costs are desired
• Petroleum refineries, chemical, petrochemical, and other heavy
process industrial facilities
• Mounting to a wall, structure, or pole (with pole mount adapter
accessory)

6L

Features and Benefits:
• NEMA 7 × 6 floodlight distribution
pattern is standard – ideal light
distribution for industrial applications;
requires fewer luminaires in general
lighting applications than required when
using general area luminaires with high
bay reflectors
• Internal reflector – available in wide and
narrow beam options; enclosed in glass
tube, reducing maintenance and
enhancing light output
• Heavy duty, cast copper-free aluminum
construction with epoxy powder coat
finish and stainless steel hardware –
provides long life in industrial, abusive
environments
• Explosionproof threaded construction –
suitable for hazardous and industrial
applications; easy to maintain with no
bolted covers
• O-ring gaskets on all threaded openings
– allow NEMA Type 4X and marine listing
for the harshest outdoor environments
• 40°C, 55°C, and 65°C ambient suitability
– ideal for use in high ambient
temperature areas common in industrial
facilities
• Factory-sealed ballast housing – keeps
ballast isolated from wiring chamber
• Trunnion (yoke) mount design – standard
construction provides the greatest
mounting flexibility; can be vertically
(wall) or horizontally (rooftop or floor)
mounted
• Simple installation – requires only two
bolts to mount
• Mounting flexibility – pole mount with
SFA6-XP pole mount adapter (shown
below) or wall or ceiling mount with
FZD-KIT1 mounting accessory kit
(shown above)

FZD with separate ballast
enclosure

Certifications and
Compliances:
NEC/CEC
• Class I, Division 1, Group B (with suffix GB*), C, D
• Class I, Zone 1, Group IIB+H2 (with suffix
-GB*), IIB
• AEx d IIB+H (with suffix -GB*), IIB
• Ex d IIB+H2 (with suffix -GB*), IIB
• Marine Locations
• Wet Locations
• Enclosure Type 4X
• IP66
• UL Listed (UL Standards 844, 1598,
1598A, 2279)
• cUL Listed (certified by UL to CSA
Standard C22.2 No. 137 and CAN/CSAE60079-1)
*See options for Group B and IIB+H2 ordering
information.

Standard Materials:
• Luminaire housing, covers, socket
holder, lamp tube end rings – copperfree aluminum
• External hardware – stainless steel
• Glass lamp tube – heat- and impactresistant tempered glass
• O-ring gaskets – neoprene/silicone
• Yoke – aluminum
• Trunnion adapter – brass

Standard Finishes:

Pole Mount Adapter

Ratings:
Sources/Wattages (Mogul Base Lamps)
• HPS – 150, 250 & 400 watts
• MH – 175, 250 & 400 watts
Voltages
Standard Voltage Ballasts
• Multi-tap (120, 208, 240 & 277 V, 60 Hz)
• 120 V, 60 Hz
• 480 V, 60 Hz
• Tri-tap (120, 277 & 347 V, 60 Hz)
Optional Voltage Ballasts
• 220 V, 60 Hz
• 220 V, 50 Hz
Hub Size
• Standard: Two 3/4" NPT entries
• Optional: Two 25 mm (M25) entries
(consult Eaton's Crouse-Hinds)

Dimensions (In Inches):

• Aluminum – Corro-free™ epoxy powder
coat
• Stainless steel – natural
• Brass – natural

Luminaire Weights
(lbs.):
Luminaire
FZDS (HPS) FZDM (MH)
150 watt
72
75
175 to 250 watt 77
77
400 watt
80
80

1154

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1154-1155.qxp

12/16/2013

7:02 PM

Page 1155

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Zone 1
Marine Locations
Wet Locations, IP66

FZD Series Floodlight Luminaire

Ordering Information:
Lamp Type
Wide Beam Reflector –
7 x 6 Distribution

Voltage Suffixes:

Watts

Cat. #* Yoke
Mount With
3
/ 4" NPT Hubs

Standard
Voltages

High Pressure Sodium

150†
250
400

FZDS2NY150W/MT
FZDS2NY250W/MT
FZDS2NY400W/MT

Metal Halide

175
250
400

FZDM2NY175W/MT
FZDM2NY250W/MT
FZDM2NY400W/MT

Pulse Start Metal Halide

175
250
400

FZDM2NY175W/MT S828
FZDM2NY250W/MT S828
FZDM2NY400W/MT S828

High Pressure Sodium

150†
250
400

FZDS2NY150N/MT
FZDS2NY250N/MT
FZDS2NY400N/MT

Metal Halide

175
250
400

FZDM2NY175N/MT
FZDM2NY250N/MT
FZDM2NY400N/MT

Pulse Start Metal Halide

175
250
400

FZDM2NY175N/MT S828
FZDM2NY250N/MT S828
FZDM2NY400N/MT S828

Narrow Beam Reflector –
Spotlight Distribution

To complete the catalog number, add option suffix(es) if desired.
Example: FZDS2NY400W/MT-S658
*All FZD catalog numbers shown above are with multi-tap ballasts (120, 208, 240 & 277 V,
60 Hz). The "MT" in the catalog number may be changed to any of the voltage suffixes
listed below.
†150 watt HPS luminaires are furnished with ANSI spec/S55 ballasts for 55 V lamps.

FZD With Separate Ballast Enclosure:
Glass Fiber Reinforced Polyester Ballast Enclosure
With Cable Entry

Narrow Beam Reflector
HPS/MH
Metal Halide
High Pressure Sodium

T-Code Cat. #
x 6 Distribution
T4
NOR 000 005 192 506
T3
NOR 000 005 194 106
T3
NOR 000 005 194 006

– Spotlight Distribution
250
T4
NOR 000 005 192 505
400
T3
NOR 000 005 194 105
400
T3
NOR 000 005 194 005

Multi-tap
(120, 208, 240, 277 V, 60 Hz)
Tri-tap
(120, 277, 347 V, 60 Hz)
120 V, 60 Hz
480 V, 60 Hz

Narrow Beam Reflector
HPS/MH
Metal Halide
High Pressure Sodium

– Spotlight Distribution
250
T4
NOR 000 005 192 501
400
T3
NOR 000 005 194 101
400
T3
NOR 000 005 194 001

www.crouse-hinds.com

US: 1-866-764-5454

Suffix

/MT

220 V, 50 Hz

/220 50

/TT
/120
/480

220 V, 60 Hz

/220

Description
Suffix
• Ballast-Gard™ starter cut-out switch prevents starter pulsing
when lamp is cycling or inoperative; prolongs ballast and
igniter life (HPS only; not available with IR option) .................BG
• Factory assembled with HID lamp installed for additional
labor savings............................................................................FA
• Factory certified: Class I, Division 1, Group B and Class I,
Zone 1, Group IIB + H2 ...........................................................GB
• Instant restrike enables a hot HPS lamp to immediately
restrike after a momentary loss of arc due to voltage
fluctuation or power outage; it has no affect on the warmup period of cold lamps; available for use with 150 watt
HPS only ..................................................................................IR
• Fusing protects ballast and capacitor against abnormal line
conditions (not suitable for marine applications).....................S658*
*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.

Accessories:
(order separately)
For Pole Mounting

Cat. #

Pole mount adapter
• Class I, Division 1, Groups B, C, D
• Attach to yoke; fits 2" NPT conduit pole
Flexible explosionproof coupling
Elbow fitting
For Wall Or Ceiling Mounting
Kit includes:
EABC26-SA conduit outlet box, ECLK236 flexible
explosionproof coupling, and EL296-SA elbow fitting

SFA6-XP

ECLK236
EL296-SA
FZD-KIT1

Temperature Performance Data:
Ambient
Temp. °C

Class I,
Division 1, Zone 1

Supply
Wire °C

150 watt HPS

40
55
65

T3C
T3C
T3B

75
75
90

250 watt HPS

40
55
65

T3C
T3C
T3B

75
75
90

400 watt HPS

40
55
65

T3C
T3C
T3B

75
75
90

175 watt
Metal Halide

40
55
65

T3A
T3
T3

75
75
90

250 watt
Metal Halide

40
55
65

T3A
T3
T3

75
75
90

400 watt
Metal Halide

40
55
65

T3A
T3
T3

75
75
90

Lamp

Cat. #
NOR 000 005 192 502
NOR 000 005 194 102
NOR 000 005 194 002

Optional
Voltages

Options:

Stainless Steel Ballast Enclosure With Cable Entry
Lamp Type
Watts T-Code
Wide Beam Reflector – 7 x 6 Distribution
HPS/MH
250
T4
Metal Halide
400
T3
High Pressure Sodium
400
T3

Suffix

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1155

6L

Lamp Type
Watts
Wide Beam Reflector – NEMA 7
HPS/MH
250
Metal Halide
400
High Pressure Sodium
400

6L

1156-1157.qxp

12/16/2013

7:02 PM

Page 1156

FZD Series Floodlight Luminaire

6L

Photometric Data

Photometrics:
Note: There are no aiming angle limitations for the FZD. The only limitations are those encountered by interference of the
trunnion arm. The trunnion arm may be mounted on vertical or horizontal surfaces to overcome any limitations.

HPS Narrow Beam Reflector

HPS Wide Beam Reflector

Isofootcandle Chart

Isofootcandle Chart

FZD 400W High Pressure
Sodium (HPS)
Catalog Number FZDS2NY400N
Lamp: 400 W Clear HPS
Lumen rating: 50,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 150W HPS,
multiply footcandles by 0.32.
For 250 W HPS, multiply
footcandles by 0.6.

FZD 400W High Pressure
Sodium (HPS)
Catalog Number
FZDS2NY400W
Lamp: 400W Clear HPS
Lumen rating: 50,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 150W HPS, multiply
footcandles by 0.32.
For 250W HPS,
multiply footcandles by 0.6.

Footcandle Values For Isofootcandle Lines
Mtg. Ht.
10'
12'
16'
20'
25'

Footcandle Values For Isofootcandle Lines

A

B

C

D

E

F

G

200.00
138.89
78.13
50.00
32.00

100.00
69.44
39.06
25.00
16.00

50.00
34.72
19.53
12.50
8.00

20.00
13.89
7.81
5.00
3.20

10.00
6.94
3.91
2.50
1.60

5.00
3.47
1.95
1.25
0.8

2.00
1.39
0.78
0.50
0.32

Mtg. Ht.

6L

MH Narrow Beam Reflector

10'
12'
16'
20'
25'

A
100.00
64.99
39.06
25.00
16.00

A

B

C

D

E

F

20.00
13.89
7.81
5.00
3.20

10.00
6.94
3.91
2.50
1.60

5.00
3.47
1.95
1.25
0.80

2.00
1.39
0.78
0.50
0.32

1.00
0.69
0.39
0.25
0.16

0.50
0.35
0.20
0.13
0.08

MH Wide Beam Reflector

Isofootcandle Chart

Isofootcandle Chart

FZD 400W Metal Halide (MH)
Catalog Number
FZDM2NY400N
Lamp: 400W Clear MH
Lumen rating: 34,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 175W MH,
multiply footcandles by 0.38.
For 250W MH,
multiply footcandles by 0.6.

FZD 400W Metal Halide
(MH) Catalog Number
FZDM2NY400W
Lamp: 400W Clear MH
Lumen rating: 34,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 175W MH,
multiply footcandles by 0.38.
For 250W MH,
multiply footcandles by 0.6.

Footcandle Values For Isofootcandle Lines
Mtg. Ht.

10'
12'
16'
20'
25'

Footcandle Values For Isofootcandle Lines

B

C

D

E

F

G

50.00
34.72
19.53
12.50
8.00

20.00
13.89
7.81
5.00
3.20

10.00
6.94
3.91
2.50
1.60

5.00
3.47
1.95
1.25
0.80

2.00
1.39
0.78
0.50
0.32

1.00
0.69
0.39
0.25
0.16

Mtg. Ht.
10'
12'
16'
20'
25'

A

B

C

D

E

F

20.00
13.89
7.81
5.00
3.20

10.00
6.49
3.91
2.50
1.60

5.00
3.47
1.95
1.25
0.80

2.00
1.39
0.78
0.50
0.32

1.00
0.69
0.39
0.25
0.16

0.50
0.35
0.20
0.13
0.08

Effective Projected Area (EPA):
• For windloading
• For proper pole selection
Aiming Angle
0°
45°

1156

www.crouse-hinds.com

EPA
1.8 ft2
2.3 ft2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1156-1157.qxp

12/16/2013

7:02 PM

Page 1157

Hazard•Gard®
H.I.D. Floodlights

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Div. 1 & 2, Groups B, C, D (add suffix GB)
Cl. I, Zone 1
Marine Locations, IP66
Wet Locations

Factory-sealed
Applications:

Standard Materials:

Hazard•Gard Luminaires with Trunnion
Arm (S812 suffix) and EV912 High Bay
Reflector are used in:
• Heavy process industries where
flammable or explosive vapors or gases
are present
• Hazardous areas, both indoors and
outdoors where long life and low
maintenance costs are desired
• Petroleum refineries, chemical,
petrochemical, and other heavy process
industry facilities
• Hazardous locations requiring elevated
ambient capability
• For mounting to a wall or structure
• Mounted on a pole, when used with the
SFA6 slipfitter adapter

• Mounting module, cover, ballast
housing, guard, globe ring – copper-free
aluminum
• Globe – heat- and impact-resistant glass
• Exterior hardware – stainless steel
• Lamp socket – porcelain with stainless
steel screw shell
• Reflector – high bay: Alzak aluminum

Features:

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 and 2, Groups B
(with GB suffix), C, D
• UL Standard: 844, 595
• CSA Standard: C22.2 No. 137

Standard Finishes:
• Copper-free aluminum –
epoxy powder coat
• Alzak – natural (anodized)

Temperature Performance
Data:

Options:
Description
Suffix
Fused.................................................. S658
Not suitable for marine
applications
Ballast-Gard™.................................... BG
50-400 HPS only
Instant Restrike ..................................
IR
Cannot be used with BG
or QTZ options
50-150W LX HPS only
Quartz Auxiliary Lighting .................... QTZ
Not available with 400W MH
Uses 100 watt single-ended lamp
Lamp not included
Group B Suitability ............................. GB

Size Ranges:
• 3/4"

Electrical Rating Ranges:
• 120, 208, 240, 277, 347, 480, 600,
multi-tap*
• 50 to 400 watts

Hazard•Gard Luminaire with
Trunnion Arm (S812 suffix)
Maximum Ambient
Class I
Watts
40°C
55°C
High Pressure Sodium
50
T4
T4
70
T4
T4
100
T4
T4
150
T4
T4
200
T3A
—
250
T3A
—
400
T3A
—
Metal Halide
70
T3
100
T3
175
T3
250
T3
400
T2D

T3
T3
T3
T3
—

65°C
T3C
T3C
T3C
T3C
—
—
—
—
—
—
—
—

Note: See Section 4L for additional luminaire information.

Required Accessories:
6L

• Luminaire is factory wired; power is fed
through "wireless" connection block
which serves as a mechanical seal
between conduit and ballast
compartments, eliminating the need for
an external, field-installed seal; the result
is fast, easy installation
• High bay reflectors of Alzak® aluminum
• Internally fluted glass globes reduce
glare and provide comfortable viewing
light
• Wide range of light sources and
wattages to meet specific lighting needs
– 50, 70, 100, 150, 200, 250 and 400W
high pressure sodium (HPS); 70, 100,
175, 250 and 400W metal halide (MH)
• High power factor (90%+) ballasts
reduce power costs – allow more
luminaires per circuit
• Elevated ambient capability permits
reliable operation at high ambient
temperature; selected luminaires are
suitable for ambient temperatures up to
65°C
• Integral ballasts – separate ballasts are
not required; lowest installed cost
• Factory-sealed, porcelain, mogul base
socket
• The trunnion arm gives you the ability to
offer a Hazard•Gard floodlight with
varying degrees of adjustability between
-90° and +90°
• When mounting on a wall, there are
numerous mounting arrangements – due
to the pre-drilled openings in the wall
bracket

6L

Ordering Information
Catalog number includes guard, trunnion
arm, and high bay reflector
Hub
Luminaire
Size
Cat. #
Watts (In.)
High Pressure Sodium
3
EVMA42051/volts S812 EV3912 50
/4
3
EVMA42071/volts S812 EV3912 70
/4
3
EVMA42101/volts S812 EV3912 100
/4
3
EVMA42151/volts S812 EV3912 150
/4
3
EVMA42201/volts S812 EV3912
/4
3
EVMA42251/volts S812 EV3912
/4
3
EVMA42401/volts S812 EV3912
/4

UNL

Metal Halide

90° Angle

EVMA92071/volts
EVMA92101/volts
EVMA92171/volts
EVMA92251/volts
EVMA92401/volts
Note:

S812
S812
S812
S812
S812

EV3912
EV3912
EV3912
EV3912
EV3912

70
100
175
250
400

/4
3
/4
3
/4
3
/4
3
/4
3

Replace "volts" with Suffix from Voltage Suffix
Table below

EABC
Cat. #

Hub Size (In.)

EABC26

3

/4

Cat. #

Size

UNL205

3

/4 to 3/4

ECGJH
Cat. #

Flexible
Length

ECGJH230

30

Size
/4

3

*CSA certified luminaires are not available with multi-tap ballast or S658 fuse option.
Alzak is a registered trademark of ALCOA.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1157

1158-1159.qxp

12/16/2013

6L

7:02 PM

Page 1158

Cl. I, Div. 1 and 2, Groups C, D
Cl. I, Zone 1

RCDE Series
Incandescent Floodlights

Applications:
RCDE Incandescent Lighting Luminaires
are permanently installed to provide
general illumination in locations having
hazardous atmospheres, such as:
• Oil refineries
• Oil and gasoline loading docks
• Aircraft servicing docks and shelters
• Distilleries
• Paint manufacturing plants
• Pumping stations
• Other Class I, Groups C and D locations

Features:

6L

RCDE Incandescent Lighting Luminaires
have fixed mountings as follows:
• RCDE-6 – junction box base with four
mounting feet or 2" threaded hub (fill
sealing chamber with Chico® A after
conductors are in place)
• RCDE-6 adjustment allows rotation of
360° horizontally and 75° vertically
• Locking screws hold housing firmly in
position
• RCDE-10 – junction box base with four
mounting feet
• Door which threads into housing
includes heat- and impact-resistant lens;
door has notches or holes provided for
ease of removing or tightening
• Factory wired leads through
explosionproof seal to junction box
• Adjustment that allows rotation of 360°
horizontally and 135° vertically; locking
bolts or clamps hold housing firmly in
position

Certifications and
Compliances:
• NEC/CEC:
RCDE – Class I, Division 1 and 2,
Groups C, D; Class I, Zone 1
(see photometric data listing)
• UL Standard: 844
• CSA Standard: C22.2 No. 137
(RCDE6 only)
CEC/CSA Certified RCDE-6 - Eaton's Crouse-Hinds
Canada luminaires only.

Standard Materials:
• Body – copper-free aluminum
• Lens – glass-, heat- and impact-resistant

RCDE-6

Standard Finishes:

Junction box base
44978A
(2" threaded hub)
Junction box base (4 mtg. feet) 44719B

• Natural

Description

Size Ranges:
• RCDE – fixed mounting – 3/ 4" hubs

Capacity Ranges:
• RCDE-6 – 150 watt, PAR38 or R40; 300
watt, R40 (medium base)
• RCDE-10 – 500 watt, PAR64 Ext. Mog
End Prong

Ordering Information:
After identifying the hazardous area, select
the model of lighting luminaire required for
that area. Then from the photometric data,
select appropriate Cat. No. based on type
of mounting desired (Example: RCDE-10
No. 47282).

Temperature Performance Data:

RCDE-10
Description

Cat. #

Junction box base (4 mtg. feet)

47282A

(based on 40°C Ambient)
RCDE-6
RCDE-10

1158

150W

300W

T3B

T2B

500W
T3C

www.crouse-hinds.com

US: 1-866-764-5454

Cat. #

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1158-1159.qxp

12/16/2013

7:02 PM

Page 1159

RCDE Series

6L

Dimensions & Weights
Photometric Data
Cl. I, Div. 1 and 2, Group D
Explosionproof

Incandescent Floodlights
Dimensions (In.):

RCDE-10

RCDE-6

Fixture Weights:
Cat. #
RCDE-6
44719B
44978A
RCDE-10
47282A

Lbs. (Net)
21.0
21.0
26.0

Photometric Data:
Beam Spread
Lamp Watts
and Type
RCDE-6
150 Watt PAR38 Flood

300 Watt* R40 Flood
300 Watt R40 Spot
RCDE-10
500 Watt, PAR64
(500 PAR64/NSP)
500 Watt, PAR64 (500 PAR64/MFL)

Class I,
Groups C, D

Class I,
Group D

Class I,
Group D

Hor.

Vert.

Beam
Lumens

Av. Max.
Candle Power

60°

60°

1690

4000

28°

28°

1200

11500

123°

123°

3200

1950

60°

60°

3100

8900

19°

14°

3000

110000

35°

19°

3300

37000

55°

32°

3400

13000

6L

150 Watt PAR38 Spot

Location

500 Watt, PAR64 (500 PAR64/WFL)
*CSA certified fixtures are for 150 watt lamp maximum.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1159

1160-1161.qxp

12/16/2013

7:03 PM

Page 1160

6L

6L

1160

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1160-1161.qxp

12/16/2013

7:03 PM

Page 1161

Lighting Accessories
Hazardous and Non-hazardous

7L

Description

Page No.

Application/Selection

see page 1162

Hazardous Area Hangers
Adjustable Type
UNR

see page 1179

Flexible Type
EC Series

see page 1173

Locking Coupling
COUP Series

see page 1179

Outlet Box Type
EAHC/EFHC Series
GUA/GUF Series
CPS Series

see page 1174
see page 1178
see page 1176

Outlet Box Type with Flexible Cushion
EFHX Series

see page 1175

Non-hazardous Area Fittings
Conduit Clamps
CHS Series

see page 1171

Non-hazardous Area Hangers – Flexible Type
Ball and Cushion
ARB Series
UNJ/UNJC Series

see page 1169
see page 1167

Cushion – Vaportight
AHG Series
UNHC Series

see page 1167
see page 1171

Hooks and Loops
UNE, UNH, UNHC Series

see page 1170

AL Series

see page 1166

Quick Disconnect Type
FHM Series

www.crouse-hinds.com

US: 1-866-764-5454

see page 1172

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1161

7L

Outlet Box – Ball and Cushion

1162-1163.qxp

7L

12/16/2013

7:03 PM

Page 1162

Luminaire Hangers
and Accessories – For Pendant Mount
Application and Selection

Applications:

Typical Luminaire Weights:

• Luminaire hangers listed in this section
are used for pendant suspension of
incandescent, high intensity discharge,
and fluorescent industrial luminaires
• They are especially suitable for use in
locations where moisture, dust, and
corrosion are a problem

Luminaire Weight
Type
(lbs.)
Incandescent:
VAPORGARD™ Series
VDA12
11/2
VDA12G
4
VDA12GP
41/4
VDA15
11/4
VDA15G
3
VDA15GP
31/4
VDA23
11/2
VDA23G
4
V Series
V275
23/4
V2759
41/4
EV Series
EVI301
11
EVI501
24
EVA292
18
Corro•Gard® Series
NDA32
51/2
NDA32G
71/2
NDA33
NDA33G
81/4

7L

Hangers for Non-hazardous
Locations:
• Hangers listed provide a wide variety of
mounting means; luminaires may be
suspended from cast outlet boxes,
stamped steel outlet boxes, or directly
from the conduit system; also offered
are several styles of hook type hangers,
used to suspend luminaires by means of
conduit stems or support rods from
span wires, horizontal conduit and
luminaire loops
• All hangers are flexible, permitting
luminaire and supporting stem to swing
freely; this feature permits luminaires to
hang plumb and prevents damage to the
luminaire, stem, and outlet box in case
of high wind or accidental impact
• Hangers are constructed so that
luminaires cannot be rotated, thereby
eliminating wire twisting and possible
damage to connections
• Cushion hangers, listed for most styles,
include a spring which carries the weight
of the luminaire; this feature prolongs
lamp life and protects the luminaire
assembly from shock or vibration
• All hangers are easily installed; with
many, the luminaire, stem, and support
member can be assembled and wired at
the work bench before making the final
installation; with several, a quick
disconnect plug and receptacle feature
is either provided or can be easily
arranged, to facilitate luminaire
installation and removal for maintenance

Luminaire
Type
H.I.D.:
Champ® Series
DMVC2A250GP
DMVM2A175GP
DMVM2A250GP
DMVS2A070GP
DMVS2A100GP
DMVS2A150GP
LMVS2A035GP
LMVS2A050GP
LMVS2A070GP
LMVS2A100GP
VMVM2A175GP
VMVM2A250GP
VMVM2A250GR305
VMVM2A250GRD4
VMVM2A400GR305
VMVM2A400GRD4
VMVS2A050GP
VMVS2A070GP
VMVS2A100GP
VMVS2A150GP
VMVS2A200GP
VMVS2A200GR305
VMVS2A200GRD4
VMVS2A250GP
VMVS2A250GR305
VMVS2A250GRD4
VMVS2A400GP
VMVS2A400GRD4

Considerations for
Selection:

Hangers for Hazardous
Locations:

Location:
• Will it require more stringent corrosion
protection material?
• Will it be a hazardous or non-hazardous
location?
Lighting luminaire to be used:
• Some hangers can be used with a
multitude of luminaires; others are
specialized
• Weight of luminaire is a consideration in
selecting cushion hangers

• As required by NEC Article 501 and CEC
Part I Section 18, rigid conduit luminaire
stems longer than 12" must be
permanently and effectively braced or
flexibility provided in the form of a fitting
or flexible support
• A variety of hangers is offered for both
rigid conduit suspension and flexible
suspension; flexible luminaire hangers
listed comply with NEC Article 501 and
CEC Part I Section 18 and also permit
luminaires to hang plumb

1162

CAN: 1-800-265-0502

www.crouse-hinds.com

US: 1-866-764-5454

Weight
(lbs.)

313/4
33
333/4
303/4
313/4
34
103/4
113/4
113/4
121/4
171/4
34
37
341/2
38
351/2
151/4
161/4
161/4
161/2
31
34
311/2
31
34
311/2
40
401/2

Copyright© 2013 Eaton’s Crouse-Hinds Business

Luminaire
Type
Hazard-Gard® Series
EVMA50W HPS
EVMA70W HPS
EVMA100W HPS
EVMA150W HPS (55V)
EVMA150W HPS (100V)
EVMA175W MH
EVMA200W HPS
EVMA250W HPS
EVMA250W MH
EVMA400W HPS
EVMA400W MH
Fluorescent:
DMVF2A026GP
DMVF2A039GP
DMVFB2A026GP
DMVFB2A039GP
EVF22062
EVF24062
EVF22082
FVN4240
FVN4340
FVN4260
NFW4240
VFA222G
EVFT (2 Lamp)
EVFT (4 Lamp)
FVS
Reflector/Refractor Type
EV3912
RA64, 636
RA70, 71, 739, 725
RD64, 636
RD70, 71, 739, 725
PR2, 3, 5
R2
R5
GRD4
G241
G245
GR305, GR205

Weight
(lbs.)

41
41
45
46
45
43
47
47
44
56
52
191/4
221/4
191/2
57
94
52
52
54
58
21
4
191/2
361/2
12
1
11/4
1
1
3
131/2
13
133/4
21/4
21/4
14

1162-1163.qxp

12/16/2013

7:03 PM

Page 1163

Luminaire Hangers
and Accessories – For Pendant Mount

7L

Quick Selector Chart
Quick Selector Chart

Hanger
Type
AL

Function
Outlet box and
hanger

NEC/CEC Hazardous
Area
Compliances
Cl. I, Div. 2

Use with
Luminaire
Type
Any non-hazardous
or
Class I, Div. 2

Use with
Mtg. Box
None
needed

Quick
disconnect
between
luminaire and
outlet box

Not applicable

Any non-hazardous

None
needed

AHG

Gasketed
hanger
(vaportight)

Cl. I, Div. 2;
Cl. II, Div. 2;
Cl. III
Wet locations
NEMA 3, 3R

Any non-hazardous
or
Div. 2
luminaires

Any

UNJ/UNJC

Ball and
cushion
hanger

Cl. I, Div. 2

Any non-hazardous
or
Class I, Div. 2

ARB

Ball or cushion
hanger

Cl. I, Div. 2

UNE, UNH,
UNHC

Quick
disconnect
hanger hook

EC

Luminaire
Weight
Capacity
(Ball or
Plain Type)
125 lbs.

Standard
Material
Body – Feraloy®
iron alloy
Nipple –
malleable iron
Cover – sheet
steel

125 lbs.

Body – copperfree aluminum
Cover – steel
Loop and
assembly –
copper-free
aluminum or
steel

4-30 lbs.

—

Housing –
malleable iron
and Feraloy iron
alloy
Stem support –
Feraloy iron
alloy

Any

6-48 lbs.

125 lbs.

Body –
malleable iron
Clamp –
copper-free
aluminum

Any non-hazardous
or
Class I, Div. 2

GRF

4-30 lbs.

125 lbs.

Body – Feraloy
iron alloy

Cl. I, Div. 2

Any non-hazardous
or
Class I, Div. 2

Not
applicable

12-64 lbs.

125 lbs.

Malleable iron,
copperfree
aluminum

Explosionproof
flexible
hanger

Cl. I, Groups A, B, C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
hazardous

Any

—

—

Body – bronze
hose
Fittings – steel

GUA, GUJ,
GUF

Explosionproof
boxes
and hanger
covers

Cl. I, Groups C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
hazardous

None
needed

—

125 lbs.

Boxes – Feraloy
iron alloy
Cover – copperfree aluminum

EAHC,
EFHC

Explosionproof
hanger

Cl. I, Groups A, B, C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
hazardous

None
needed

—

125 lbs.

Body – Feraloy
iron alloy
Cover – copperfree aluminum

UNR

Explosionproof
adjustable
hanger

Cl. I, Groups C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
hazardous or
non-hazardous

Any

—

125 lbs.

Feraloy iron
alloy

EFH

Explosionproof
boxes
and hangers

Cl. I, Groups C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
hazardous

None
needed

65 lbs.

—

Feraloy iron
alloy

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1163

7L

FHM

Luminaire
Weight
Capacity
(Cushion)
3-48 lbs.

1164-1165.qxp

7L

12/16/2013

7:03 PM

Page 1164

Luminaire Hangers
and Accessories — For Pendant Mount

7L

Typical Installations

1164

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1164-1165.qxp

12/16/2013

7:03 PM

Page 1165

7L

Luminaire Hangers
and Accessories — For Pendant Mount
Typical Installations

7L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1165

1166-1167.qxp

12/16/2013

7L

7:03 PM

Page 1166

AL Flexible Luminaire Hangers

Cl. I, Div. 2, Groups A, B, C, D

For Pendant Mount
ALC

Features:

ALT

Functions as both conduit outlet box and
luminaire hanger; hubs are provided for
threading the conduit directly into the
hanger body; for use with incandescent,
H.I.D., and fluorescent luminaires
• Supporting nipple, ball or cushion type,
is a universal joint permitting luminaire to
swing through an angle of 20 degrees in
any direction from the perpendicular
• Cover has one screw hole and one open
slot – easily swung aside for wiring
without removal and possible loss of
cover
• Luminaire, conduit stem, and nipple can
be assembled and wired at the work
bench; the assembly is then placed in
the hanger body and luminaire wires
spliced to the circuit wires
• Provided with a separate grounding wire
for ground connections

Ball

Ball

Cushion

Cushion

Standard Materials:
• Body – Feraloy®
• Nipple – malleable iron
• Cover – sheet steel

Standard Finishes:
• Feraloy and malleable iron – zinc
electroplate and aluminum acrylic paint
• Sheet steel – electrogalvanized with
chromate finish

7L

Size Ranges:

Ball

Ball
Luminaire
Stem
Size
/2
3
/4
3
/4
1

• Conduit hubs – 3/4" to 1"
• Luminaire stem – 1/2" and 3/4"
• Luminaire weight – cushion type, 3 to 48
lbs.; ball type, 125 lbs.

Options:
The following special options are available
from the factory by adding the suffix to the
Cat. No.:
Description
Suffix
Suspension attachment for span
wire or threaded rod (see listings)
S1

Suspension Attachment
For horizontal cable or vertical
support rod

Conduit
Size

Cat. #

/4
3
/4
1

ALC21
ALC22
ALC32

3

Luminaire
Stem
Size
/2
3
/4
3
/4
1

Luminaire
Luminaire
Stem
Conduit Weight
Size
Size
(Lbs.)
Cat. #

Luminaire
Luminaire
Stem
Conduit Weight
Size
Size
(Lbs.)
Cat. #
3

/2
/4
3
/4

/4
/4
1

3 to 6

ALT214
ALT224
ALT324

3

/2
/4
3
/4

/4
/4
1

6 to 12

ALT218
ALT228
ALT328

3

/2
/4
3
/4

/4
/4
1

12 to 24

ALT2116
ALT2216
ALT3216

/2
/4
3
/4

/4
/4
1

24 to 48

ALT2132
ALT2232
ALT3232

ALC214
ALC224
ALC324

1

3 to 6

/4
/4
1

1

6 to 12

ALC218
ALC228
ALC328

/2
/4
3
/4

/4
/4
1

12 to 24

ALC2116
ALC2216
ALC3216

1

3

/2
/4
3
/4

/4
/4
1

1

24 to 48

ALC2132
ALC2232
ALC3232

3

/2
/4
3
/4

/4
/4
1

3

/2
/4
3
/4

1

1

1

3
3

3
3

3
3

3
3

3

AL hangers can be furnished with a loop
fastened to the top of the body to provide
a means for suspending luminaires from
vertical support rods or horizontal span
wires. The loop will take a wire or cable
with a maximum diameter of 3/ 8". The boss
on top of the loop is tapped 3/ 8"-16 to
accept a threaded rod.

US: 1-866-764-5454

ALT21
ALT22
ALT32

Cushion

3

www.crouse-hinds.com

Cat. #

/4
3
/4
1
3

Cushion

1

1166

Conduit
Size

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

3
3

3
3

3
3

3
3

1166-1167.qxp

12/16/2013

7:03 PM

Page 1167

AHG, UNJ and UNJC Flexible
Luminaire Hangers

AHG – Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 2, Groups F, G
Cl. III
Wet Locations, NEMA 3, 3R
UNJ, UNJC – Cl. I, Div. 2, Groups A, B, C, D

For Pendant Mount

7L

Features:

Standard Materials:

AHG

• For connection to conduit hub or hub
cover of supporting conduit fitting
• For incandescent, H.I.D., and fluorescent
luminaires
• Cushion support for conduit stem is a
universal joint permitting luminaire to
swing through an angle of 8 degrees in
any direction from the perpendicular
• Gasketed by means of a durable
neoprene diaphragm which excludes
moisture and dirt from both luminaire
and conduit system

• Housing: top cap – malleable iron;
bottom cap – Feraloy® iron alloy
• Luminaire stem support – Feraloy iron
alloy

Cushion Vaportight for Class I,
Div. 2; Class II, Div. 2: Class III

Certifications and
Compliances:
•
•
•
•
•

Standard Finishes:
• Feraloy iron alloy and malleable iron –
electrogalvanized and aluminum acrylic
paint

Size Ranges:
• Male nipple – 3/4"
• Luminaire stem – 3/4"
• Luminaire weight – 4 to 30 lbs.

Class I, Division 2
Class II, Division 2
Class III
Wet Locations
NEMA 3, 3R

Luminaire Male
Luminaire
Stem
Nipple Weight
Size*
Size*
(Lbs.)
Cat. #
/4
/4
3
/4

3

3

3

UNJ

UNJC

Standard Finishes:

Ball

Cushion

• Malleable iron – electrogalvanized and
aluminum acrylic paint
• Copper-free aluminum – natural finish

Luminaire
Stem
Size

Male
Nipple
Size

Cat. #

/2
3
/4

1

/2
3
/4

UNJ1
UNJ2

Features:

/4
/4
3
/4

3

4 to 8
8 to 16
16 to 30

AHG22103
AHG22104
AHG22111

• For connection to conduit hub or hub
cover of supporting conduit fitting
• For incandescent, H.I.D., and fluorescent
luminaires
• Supporting nipple, ball or cushion type,
is a universal joint permitting luminaires
to swing through an angle of 20 degrees
in any direction from the perpendicular

7L

Certifications and
Compliances:
• NEC: Class I, Division 2

Standard Materials:
• Body and nipple – malleable iron
• Clamp – copper-free aluminum

1

Size Ranges:
• Male nipple – 1/2" and 3/4"
• Luminaire stem – 1/2" and 3/4"
• Luminaire weight: cushion type – 6 to 48
lbs.; ball type – 125 lbs.

Luminaire
Stem
Size*

Male
Nipple
Size*

Luminaire
Weight
(Lbs.)
Cat. #

3

/4
/4
1
/2
3
/4

3

3

3

/4
/4
/2
3
/4

6 to 12
12 to 24
24 to 48
24 to 48

1

UNJC28
UNJC216
UNJC132
UNJC232

*1/2" connection can be made by using reducers.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1167

1168-1169.qxp

12/16/2013

7L

7:04 PM

Page 1168

Flexible Luminaire Hangers
For Pendant Mount
Dimensions

Dimensions
In Inches:

UNJ

AL Series - Ball

UNJC

7L

AL Series - Cushion

AHG

1168

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1168-1169.qxp

12/16/2013

7:04 PM

Page 1169

7L

Cl. I, Div. 2, Groups A, B, C, D

ARB Flexible
Luminaire Hangers
For Pendant Mount

For GRF and VXF outlet boxes only

Features:
• Available in two styles – one for direct
attachment to GRF cast outlet boxes by
4 screws, the other for direct attachment
to 4" octagonal stamped steel outlet
boxes by 2 screws; for incandescent,
H.I.D., and fluorescent luminaires
• Both styles available with ball or cushion
support for conduit stem to permit
luminaire swing in any direction; ball type
provides 11 degree swing, cushion type
8 degree swing from the perpendicular
• Gasketed cushion hangers for GRF are
provided with a durable neoprene
diaphragm which excludes moisture and
dirt from both luminaire and conduit
system

Ball
Luminaire
Stem
Description Size
1
/2
Surface
1
Flush
/2
3
Surface
/4
Ball

Cushion

Cat. #
ARB62
ARB67
ARB662

Luminaire
Stem
Size

Luminaire
Weight
(Lbs.)

Cat. #

/2
1
/2
1
/2

4 to 8
8 to 16
16 to 30

ARB82
ARB102
ARB122

Cushion Surface –
Vaportight with Neoprene
Diaphragm

• Mounting plate for GRF – Feraloy® iron
alloy; for 4" outlet boxes – sheet steel
• Hanger body and luminaire stem support
– Feraloy iron alloy

• Feraloy – electrogalvanized and
aluminum acrylic paint
• Sheet steel – electrogalvanized with
chromate finish

Luminaire
Weight
(Max.)
125
125
125

Cushion Surface

1

Standard Materials:

Standard Finishes:

ARB Fits GRF and VXF
Outlet Boxes

For GRF and VXF outlet boxes
and 4" octagonal outlet boxes

Luminaire
Weight
(Lbs.)

Cat. #

/2
1
/2
1
/2

4 to 8
8 to 16
16 to 30

ARB821
ARB1021
ARB1221

1

ARB Fits GRF, VXF and 4"
Outlet Boxes

Size Ranges:
• Luminaire stem – 1/2" and 3/4"
• Luminaire weight: cushion type – 4 to 30
lbs.; ball type – 125 lbs. (ARB6 and
ARB2 maximum weight 60 lbs.)

Luminaire
Stem
Size

Ball

Ball

Cushion

Luminaire
Stem
Size

Luminaire
Weight
(Max.)

Cat. #

/2
3
/4

60
60

ARB6
ARB2

Luminaire
Stem
Size

Luminaire
Weight
(Lbs.)

Cat. #

/2
1
/2
1
/2

4 to 8
8 to 16
16 to 30

ARB8
ARB10
ARB12

1

1

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

7L

Cushion

Copyright© 2013 Eaton’s Crouse-Hinds Business

1169

1170-1171.qxp

12/16/2013

7:04 PM

Page 1170

Cl. I, Div. 2, Groups A, B, C, D

UNE, UNH and UNHC Flexible
Luminaire Hangers

7L

For Pendant Mount
The following applies to all items on this page:

Applications:
• Provides a simple, inexpensive, quick
disconnect method for hanging pendant
luminaires; for incandescent, H.I.D., and
fluorescent luminaires
• Permits free swing in any direction to
prevent damage to luminaire stem;
cushion style provides additional
protection from vibration to prolong
lamp life

Features:
• Female hooks and loops are used with
rigid conduit luminaire stems to suspend
luminaires; they may also be used with
male hooks and loops, threaded into a
conduit outlet hub
• All hooks and loops are provided with
openings for passage of luminaire wires;
luminaire, conduit stem, and hook or
loop can be assembled and wired at the
work bench; the assembly is then hung
on the fixed hook and connection made
• For ease of relamping and maintenance,
the outlet fitting can be equipped with
an attachment plug receptacle cover
and a matching plug cap used with the
luminaire assembly; for permanent
wiring, a wire hole cover may be used

Male

Female

Male

UNH

Female
UNE

UNE and UNH Flexible Luminaire Hangers
For Pendant Mount
Type

Style
Male

UNH
Female

Luminaire
Stem Size

Luminaire
Weight (Lbs.)

Cat. #

1

/2
3
/4
1
/2
3
/4

125
125
125
125

UNH16
UNH26
UNH1
UNH2

/2
/4
1
/2
3
/4

125
125
125
125

UNE16
UNE26
UNE1
UNE2

1

Male

3

UNE
Female

Applicable to UNE and UNH (upper
listings) only:

Features:
• Diameter of wire opening: 1/2"

Standard Materials:
7L

• Malleable iron

Standard Finishes:
• Cadmium electrogalvanized and
aluminum acrylic paint

Size Ranges:
• Luminaire stem or hub – 1/2" and 3/4"
• Luminaire weight – 125 lbs.

Female

Female Cushion

Applicable to UNH and UNHC (lower
listings) only:

UNH and UNHC Flexible Luminaire Hangers

Features:

Type

Style

• Hooks are shaped to permit easy
installation of large heavy luminaires,
such as H.I.D. and fluorescent units
• Diameter of wire opening: 5/8"

UNH

Female

Luminaire
Stem Size

Luminaire
Weight (Lbs.)

Cat. #

1

/2

125

UNH182

/4
3
/4
3
/4

12 to 24
24 to 48
48 to 64

UNHC216
UNHC232
UNHC264

3

UNHC

Female
Cushion

Standard Materials:
• Copper-free aluminum

Standard Finishes:
• Natural

Size Ranges:
• Luminaire stem – 1/2" and 3/4"
• Luminaire weight: cushion type – 12 to
64 lbs.; plain type – 125 lbs.

1170

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1170-1171.qxp

12/16/2013

7:04 PM

Page 1171

7L

No Wireway Opening

UNHC Flexible Luminaire Hangers
For Support Only
CHS Conduit Clamp; UNH Conduit Hook;
For Pendant Mount Fluorescent Luminaires
Applications:
• Used for support of pendant fluorescent
luminaires
• UNHC provides cushion support for
luminaires suspended by 1/4" or 5/16"
threaded rod, and is used with the ring
of CHS conduit clamps
• UNH hook provides an extremely simple
means of conduit suspension for the
unwired end of a fluorescent luminaire,
as it merely hooks over the horizontal
supporting conduit

UNHC Cushion Luminaire
Hangers

CHS Conduit Clamp and
UNH Hook

Features:
• The bushing in UNHC cushion hangers is
tapped for both 1/4" and 5/16" suspension
rod, with the lower half tapped 5/16";
either size rod can be used without
reversing the bushing
• CHS conduit clamp firmly grips the
conduit and the ring at bottom accepts
either a hooked rod or the UNHC
cushion hanger for threaded rod; will
also accept UNH and UNHC hangers for
conduit stem listed on the preceding
page
• The UNH conduit hook fits over conduit
up to and including 1" and has a hub for
attachment of a 1/2" conduit stem

Clamp
Luminaire
Weight
(Lbs.)

Support
Rod
Tap

Cat. #

12 to 24
24 to 48
48 to 64

1

/4"-20
and
5
/16"-18

UNHC2816
UNHC2832
UNHC2864

Hook

Conduit
Size

Clamp
Cat. #

Hook
Cat. #

/2
/4
1

CHS1437
CHS2437
CHS3437

UNH13

1

3

Hook
Hub
Size
/2

1

Standard Materials:
• UNHC – copper-free aluminum
• CHS: body – malleable iron; clamp –
copper-free aluminum; ring – steel wire
• UNH – Feraloy® iron alloy

Standard Finishes:
7L

• Copper-free aluminum – natural finish
• Feraloy and malleable iron –
electrogalvanized and aluminum acrylic
paint
• Steel wire – electrogalvanized with
chromate finish

Size Ranges:
• Luminaire stem (UNH) – 1/2"
• Conduit (CHS): 1/2" to 1"
• Luminaire weight: UNHC cushion – 12 to
64 lbs.; CHS, UNH – 125 lbs.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1171

1172-1173.qxp

12/16/2013

7L

7:04 PM

Page 1172

FHM Power Hook
Luminaire Hangers
For Pendant Luminaires

Features:

FHM

• For mounting H.I.D. type luminaires in
non-hazardous locations
• Power hook housing has two 3/4"
through-feed hubs and one 3/4" hub on
the top for pendant mounting; throughfeed hubs are furnished with flush plugs
• Cast mounting lugs are provided for
direct ceiling mounting
• Housing contains a roomy 15 cu. in.
splicing chamber and interlocking type
receptacle with leads
• Plugs and receptacles are interlocking
type to prevent accidental
disengagement; when plug is inserted,
hook is blocked and luminaire assembly
cannot be removed; to service the
luminaire, pull the plug, unhook the loop
luminaire assembly, and take it to a
convenient servicing area
• Loop can move a maximum of 30°,
allowing the power hook to be mounted
on a canted ceiling; the luminaire
assembly will hang true to the vertical
• Loop and hook are shaped for selfalignment and resist twisting of luminaire
by gusts of wind or light drafts
• Supporting loop is furnished with 16" of
#16-3/C type SO cord and an
interlocking type plug

For H.I.D. Type Luminaires
with Voltages up to 480 Volts
Loop

Hubs*

Plain

3

/4

Luminaire
Stem*

Luminaire
Weight
(Lbs.)

Cat. #

/4

125

FHM201

3

Plain

Dimensions
In Inches:

Certifications and
Compliances:
• Meet UL and NEMA requirements for the
listed electrical ratings

7L

Standard Materials:
• Power hook body – copper-free
aluminum
• Access cover – zinc plated cold rolled
steel
• Loop – copper-free aluminum

Standard Finishes:
• Copper-free aluminum – natural finish
• Steel – electrogalvanized with chromate
finish
Plain

Size Ranges:
• Hubs – 3/4"
• Luminaire weights: loop – up to 125 lbs.
• Loop luminaire stem size – 3/4"

Electrical Rating Ranges:
• 480 volts, 14 amps, 2 wire, 3 pole

*1/2" connection can be obtained by using reducers.

1172

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1172-1173.qxp

12/16/2013

7:04 PM

Page 1173

ECHF Flexible Luminaire
Supports

Cl. I, Div. 1 & 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

For Pendant Mount

Explosionproof
Dust-Ignitionproof

7L

Applications:
ECHF Series Flexible Luminaire Supports
are used in hazardous locations:
• Where a luminaire must hang more than
12" from its supporting junction box (as
specified by NEC Article 501 and CEC
Part I Section 18)
• To assure that luminaires hang plumb
and will swing freely if accidentally
struck; prevents damage to luminaire
and supporting outlet fitting

ECHF

Ordering Information:
Description

Features:
• Complies with NEC Article 501/CEC Part
I Section 18
• Free swinging in any direction through a
large arc
• Good electrical continuity – no bonding
jumpers needed
• Watertight construction
• Insulating liner of asphalt impregnated
fiber to protect conductors
• Constructed to reinforced flexible metal
hose
• Two female end fittings, each with a
removable short nipple
• Nipples fit set-screw type luminaire hubs
• Female end fittings are equipped with
set-screws to prevent turning during
relamping and loosening of fitting with
vibrations

Flexible
Length

Nipple
Size

Overall
Length

Cat. #

/2
3
/4

10
10

ECHF14
ECHF24

/2
/4

12
12

ECHF16
ECHF26

/2
/4

14
14

ECHF18
ECHF28

/2
/4

16
16

ECHF110
ECHF210

/2
/4

18
18

ECHF112
ECHF212

/2
/4

21
21

ECHF115
ECHF215

/2
/4

24
24

ECHF118
ECHF218

1

4

1

6

3
1

8

3
1

10

3
1

12

3
1

15

3
1

18

3

Certifications and
Compliances:

7L

• NEC/CEC:
Class I, Groups A, B, C, D
Class II, Groups E, F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Standard Finishes:
• Brass and bronze – natural

Standard Materials:
•
•
•
•

Inner core – brass
Outer braid – bronze
End fittings – bronze
End fittings – brass (CSA certified units)

Options:
Description
Suffix
Material – stainless steel hose and
end fittings............................................ S516
Finish – flexible neoprene protective
coating.................................................. S758
Special lengths and sizes
available........................Detailed information
on request

Size Ranges:
• Flexible length – 4" to 18"
• Nipple size – 1/2" and 3/4" (see "Options")
• Luminaire weight – up to 125 lbs.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1173

1174-1175.qxp

12/16/2013

7L

7:04 PM

Page 1174

EAHC and EFHC
Luminaire Hangers

Cl. I, Div. 1 & 2, Groups A*, B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

For Pendant Mount
Applications:

Mounting Strap

EAHC* and EFHC

EAHC and EFHC Luminaire Hangers are
for use in hazardous areas to:
• Suspend explosionproof pendant
luminaires from the conduit system
• Function as both conduit outlet box and
luminaire hanger

Mounting strap can be furnished to fasten
luminaire hangers to mounting surface,
independent of conduit straps. To order,
add suffix S294 to EAHC or EFHC Cat. No.

Features:

Suspension Attachment

• Through-feed hubs are provided for
threading the conduit directly into the
hanger body
• Has large threaded cover for
accessibility and ease of wiring
• Bottom hub, threaded or union style, is
equipped with set-screws to securely
lock luminaire stem in place; takes
conduit stem or EC flexible luminaire
hanger for stems longer than 12" (in
compliance with NEC Article 501 and
CEC Part I Section 18)

With Union Hub
EAHC and EFHC hangers can be furnished
with a loop fastened to the top of the body
to suspend luminaire and conduit from
vertical support rods or horizontal span
wires. The loop will take a wire or cable
with a maximum diameter of 3/ 8". The boss
on top of the loop is tapped 3/ 8"–16 to
accept a threaded rod. To order, add
suffix S1 to Cat. No.

Certifications and
Compliances:
With Threaded Hub

• NEC/CEC:
EAHC –
Class I, Groups A, B, C, D
Class II, Groups E, F, G
Class III
EFHC –
Class I, Groups C, D
Class II, Groups E, F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Ordering Information:
Luminaire
Hub Stem
Size Size
EAHC*
1
/2
3
/4
3
/4

Standard Materials:

Threaded
Hub for
Luminaire
Stem
Cat. #

Union
Hub for
Luminaire
Stem
Cat. #

EAHC2701 EAHC2601
EAHC2702 EAHC2602

/2
/4

EAHC3701 EAHC3601
EAHC3702 EAHC3602

/2
/4

EFHC2701 EFHC2601
EFHC2702 EFHC2602

/2
/4

EFHC3701 EFHC3601
EFHC3702 EFHC3602

1

1

7L

Explosionproof
Dust-Ignitionproof

3

EFHC

• Bodies – Feraloy® iron alloy
• Covers – copper-free aluminum

1

/4

3

3
1

Standard Finishes:

1

• Feraloy – electrogalvanized and
aluminum acrylic paint
• Copper-free aluminum – natural

Dimensions

3

In Inches:

Options:
Description
Suffix
Finish – Corro-free™ epoxy enamel ..... S752
Suspension attachment for span wire or
threaded rod (see listings) ................... S1
Mounting strap (see listings) ............... S294

Size Ranges:
• Conduit hubs – 3/4" and 1"
• Luminaire stem – 1/2" and 3/4"
• Luminaire weight – 125 lbs.

*EAHC only.

1174

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1174-1175.qxp

12/16/2013

7:04 PM

Page 1175

EFH Flexible Cushion
Luminaire Hangers

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 and 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

For Pendant Mount

7L

Applications:
EFH Flexible Cushion Luminaire Hangers
are used in hazardous locations:
• Where a luminaire must hang more than
12" from its supporting junction box (as
required by NEC Article 501 and CEC
Part I Section 18)
• To assure that luminaires hang plumb
and will swing freely if accidentally
struck; prevents damage to luminaire,
stem, and supporting outlet box
• To provide a cushion support, prolonging
lamp life and protecting the luminaire
from shock and vibration; for luminaires
weighing up to 65 lbs.

EFHX
Body
Hub
Size*
/2 and 3/4
/2 and 3/4

Features:
• Complies with NEC Article 501 and CEC
Part I Section 18
• Free swinging in any direction through
an angle of 15 degrees from
perpendicular
• Weight of luminaire is supported by a
high strength brass bellows and a
stainless steel cushioning spring
• Two part assembly consisting of
luminaire hanger cover and CPS12
outlet box; provides a wide variety of
conduit arrangements; a set-screw locks
the conduit stem in place

Certifications and
Compliances:

Luminaire
Stem
Size

With
Mtg. Feet
Cat. #

/2
/4

EFHX111
EFHX221

1

1

1

3

Cushion
Luminaire
Hanger Only
Stem
Size

Cat. #

/2
3
/4

EFH01
EFH02

1

• NEC/CEC:
Class I, Groups C, D
Class II, Groups E, F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Dimensions
7L

In Inches:

Standard Materials:
• Feraloy® iron alloy

Standard Finishes:
• Electrogalvanized and aluminum acrylic
paint

Size Ranges:
• Conduit hubs – 3/4" with 3/4" to 1/2"
reducers
• Luminaire stem – 1/2" and 3/4"
• Luminaire weight – 65 lbs. max.

*Furnished with four

/ " standard taper tapped, integrally bushed hubs. Each hub as a / " to / " reducer. Three hubs are plugged.

3

3

4

www.crouse-hinds.com

4

1

2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1175

1176-1177.qxp

12/24/2013

7L

3:19 PM

Page 1176

Condulet® Conduit Outlet Boxes
with Covers

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Applications:
CPS Series Conduit Outlet Boxes are
installed in conduit systems in hazardous
areas to:
• Protect conductors in threaded rigid
conduit
• Act as pull and splice boxes
• Change conduit direction
• Interconnect lengths of conduit
• Act as luminaire hangers with hub
covers
• Provide access to conductors for
maintenance and future system changes

Box with Hub Cover

Box with Blank Cover

Hub Size
Body*

Hub
Size

Cat. #

/2 and 3/4

CPS12026

/2 and /4
/2 and 3/4

1

Features:

3

1

Cover
/2
/4

Cat. #
CPS12021
CPS12022

1
3

1

CPS Conduit Outlet Boxes have:
• Two types of cover:
-Blank for splice or pull box use
-Threaded hub for mounting luminaires
• Wide, accurately machined body and
cover mating surfaces, to ensure
flame-tight joint
• Blind tapped holes for cover screws to
further ensure flame-tightness
• Removable mounting feet for flush or
surface mounting to wall or ceiling

Body

Certifications and
Compliances:

Cat. #

Hub Size

Cat. #

/2 and 3/4

CPS12

1

/2
3
/4

CPS021
CPS022

1

• NEC/CEC:
Class I, Groups C, D
Class II, Groups E, F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

7L

Hub Covers

Hub Size*

*Furnished with four
plugged.

/ " standard taper tapped, integrally bushed hubs. Each hub has a / " to / " reducer. Three hubs are

3

3

4

Dimensions
In Inches:

Standard Materials:
• Feraloy® iron alloy

Standard Finishes:
• Electrogalvanized and aluminum
acrylic paint

Options:
Description
Corro-free™ epoxy enamel

1176

www.crouse-hinds.com

Suffix
(information
available on
request)

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4

1

2

1176-1177.qxp

12/24/2013

3:19 PM

Page 1177

GUA Series Outlet Bodies
and Luminaire Hanger
Covers

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

7L

Explosionproof
Dust-Ignitionproof

Applications:
GUA, GUF and GUJ Outlet Bodies are
used:
• With luminaire canopies, union hub and
nipple covers for mounting EVA, EVM,
EVLP, and EVF luminaires

Features:
• A threaded cover opening in the side of
the canopy permits access to the interior
for making splices or taps
• The luminaire with its conduit stem and
canopy is wired before installation,
which eliminates wire twisting when the
canopy is screwed into the outlet body
• Union hub covers permit the cover to be
screwed into the body without twisting
wire leads
• All covers have set-screws to lock the
conduit stem or EC series flexible
luminaire support firmly to the cover

GUAT

GUA
Hub Size (In.)

Cat. #

Hub Size (In.)

Cat. #

/2
3
/4
1

GUA160
GUA260
GUA360

1

/2
3
/4
1

GUAT160
GUAT260
GUAT360

1

Certifications and
Compliances:
GUAC

• NEC/CEC:
Class I, Groups C, D
Class II, Groups E, F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

GUAX

Hub Size (In.)

Cat. #

Hub Size (In.)

Cat. #

/2
3
/4
1

GUAC160
GUAC260
GUAC360

/2
3
/4
1

GUAX160
GUAX260
GUAX360

1

1

Standard Materials:

7L

Outlet bodies:
• GUA Series – Feraloy iron alloy
• GUFX – copper-free aluminum
Luminaire hanger covers:
• GUA068 – Feraloy iron alloy
• GUA0687, GUA0672 – copper-free
aluminum

GUAL
Hub Size (In.)

Cat. #

/2
3
/4
1

GUAL160
GUAL260
GUAL360

1

Standard Finishes:
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint
• Copper-free aluminum – natural

Dimensions
In Inches:

Options:
Description
Suffix
Finish – Corro-free™ epoxy
enamel................................................ S752

Size Ranges:
• Bodies – 1/2" to 1" hubs
• Canopies – 1/2", 3/4" and 11/4" luminaire
stem
• Union hub and nipple covers – 1/2" and
3
/4" luminaire stem

GUA Series
Hub Size
/2
3
/4
1
1

www.crouse-hinds.com

a

b

c

d

e

3 /2
31/2
31/2

2
2
25/16

3
3
3

5

/8
/4
7
/8

/8
/8
1

1

US: 1-866-764-5454

CAN: 1-800-265-0502

3

7
7

Copyright© 2013 Eaton’s Crouse-Hinds Business

1177

1178-1179.qxp

12/16/2013

7:04 PM

Page 1178

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

GUA Series Outlet Bodies and
Luminaire Hanger Covers

7L

GUFX

Explosionproof
Dust-Ignitionproof

Luminaire Hanger Covers
For GUA and GUF Series Junction Boxes

Hub Size

Cat. #

/2
/4

GUFX160
GUFX260

1
3

Nom. Dia. Luminaire Luminaire Luminaire Covers Nipple
Cover
Stem
Canopies Union Hub
Covers
Opening Size
Cat. #
Cat. #
Cat. #
3

/4

3

GUA068

GUA0687

Dimensions
In Inches:

Hanger Covers

7L

GUA 068

GUF Series
Hub Size
1
/2
3
/4

a

b

c

d

e

f

g

31/2
31/2

2
2

3
3

5

/8
3
/4

7

/8
7
/8

5

/16
5
/16

53/8
53/8

1

31/2

23/8

3

7

/8

1

5

/16

53/8

GUA 0687

GUA 0671

1178

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

GUA0672

1178-1179.qxp

12/16/2013

7:04 PM

Page 1179

UNR Adjustable Luminaire
Hangers; COUP Locking
Couplings

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Explosionproof
Dust-Ignitionproof

7L

For Pendant Mount
Applications:
UNR Adjustable Luminaire Hangers are
used in hazardous areas to:
• Mount between a luminaire and its outlet
box so that the luminaire can be
adjusted within the range of 0 degrees to
90 degrees
• Permit pendant type luminaires to
illuminate vertical surfaces such as a
control board
• Hang luminaires plumb when the
supporting outlet box is not horizontal

Certifications and
Compliances:

UNR
Adjustable Luminaire Hanger

• NEC:
Class I, Groups C, D
Class II, Groups E, F, G
Class III
• UL Standard: 1203

Standard Materials:
• Feraloy iron alloy

Standard Finishes:

Features:
The luminaire is nippled onto one end of
the UNR, and the other end of the UNR is
nippled into the support outlet box
• Set-screws are located on each end to
lock the nipples in place to prevent
loosening in relamping or from vibration
• Adjustment of UNR to the angle setting
needed provides for the desired angle of
the luminaire
• Degree markings are cast into the UNR
• Two set-screws and a large stud and nut
are provided, which are tightened to
clamp the unit rigid

Applications:

Size Ranges:
• Hub – 3/4"
• Luminaire weight – 125 lbs.

Angle
Adjustment

Cat. #

/4

0° to 90°

UNR29

3

Dimensions
In Inches:

Certifications and
Compliances:

COUP
Locking Couplings

• UL Standard: 1203

Standard Materials:
• Feraloy iron alloy

Standard Finishes:
• Electrogalvanized and aluminum acrylic
paint

Size Ranges:
• Hub size – 1/2" to 1"
• Stem size – 1/2" and 3/4"

Features:

Hub
Size

7L

COUP Locking Couplings are used in both
hazardous and non-hazardous areas to:
• Lock a luminaire conduit stem into a
conduit hub to prevent the conduit stem
from loosening when the luminaire is
relamped and torque transferred to
luminaire stem
• Prevent loosening of luminaire stem due
to vibration
• Hang pendant type luminaires from
standard cast outlet boxes which do not
have set-screws in the hub where the
luminaire stem is attached

• Electrogalvanized and aluminum acrylic
paint

• The large end is slipped over the cast
hub and the set-screws tightened; the
luminaire stem is slipped through the
small end and threaded securely into the
cast hub; the set-screws in the small end
are then tightened, thereby preventing
the stem from turning
• Permits support of luminaire from
conduit hub of a hazardous location
outlet body

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Hub Size

Stem Size

Cat. #

/2
3
/4
3
/4
1

1

/2
1
/2
3
/4
3
/4

COUP101
COUP201
COUP202
COUP302

1

Copyright© 2013 Eaton’s Crouse-Hinds Business

1179

1180-1181.qxp

12/17/2013

5:50 PM

Page 1180

7L

7L

1180

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1180-1181.qxp

12/17/2013

5:50 PM

Page 1181

Portable Lighting
Hazardous and Non-hazardous

8L

Description

Page No.

Application/Selection

see page 1182

Hand Lamps
VS Series Incandescent
EVH Series Incandescent
EVH Series Fluorescent

see page 1183
see page 1184
see pages 1188–1189

Portable Floodlights
RCDER Series Incandescent
EVP Series H.I.D.

see page 1185
see page 1187

Work Lights
EVH Series Fluorescent

see pages 1188–1189

8L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1181

1182-1183.qxp

12/16/2013

7:05 PM

Page 1182

Portable Lighting

8L

Hazardous and Non-hazardous Locations
Application and Selection
Quick Selector Chart
Applications:
Portable luminaires and accessories can
be used:
• In areas made hazardous by the
abnormal presence of flammable gases
and vapors, combustible dusts, or easily
ignitable fibers and flyings
• In areas where combustible dusts and
flammable gases are present
simultaneously
• In aircraft manufacturing and
maintenance facilities, shipyards, paint
spray booths, refueling depots, storage
tank cleanings, railcar manufacturing and
maintenance facilities, refineries,
chemical and petrochemical plants,
textile mills, grain elevators,
pharmaceutical plants, sewage
treatment plants, and wastewater
treatment plants
• During plant 'shut downs' for
maintenance and installation
requirements
• In any adverse environment where
portable lighting is preferred or required
• In locations where fixed lighting is not
practical
• For task oriented lighting
• For emergency lighting applications
• When inspecting aircraft wing tanks,
vats, process vessels, fuel tanks, etc.
(hand lamps)

Considerations for
Selection:
Environmental:
• What is the hazardous area
classification (NEC/CEC) of the location
in which the luminaires will be installed?
• What wattages and light source (ie.
fluorescent) will provide the desired light
levels?
• Type of luminaire required: handlamp,
portable flood, or other special
requirements

Table 500.8(C)
Identification Numbers.
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Temperature
Class
(T Code)
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

8L

Quick Selector Chart
Luminaire
EVH Hand Lamp
(Incandescent)

NEC Hazardous
Area
Compliances
Cl. I, Groups C and D
Cl. II, Group G
Cl. III

Lamp
Watts
100 max.

Volts
250 VAC

EVH Hand Lamp
(Fluorescent)

Cl. I, Groups C and D
Cl. II, Groups E, F, G
Cl. III

13, 15

120, 220-50

EVP

Cl. I, Groups C and D
Cl. II, Groups F and G
Cl. III

35-150

120, 277, 347

RCDER

Cl. I, Groups C and D

150-500

VS

Non-hazardous areas

100 max.

1182

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1182-1183.qxp

12/16/2013

7:05 PM

Page 1183

VS Portable Hand Lamps

Weather Resistant

8L

Incandescent
Accessories
Applications:
The incandescent VS Portable Hand Lamps
are used:
• In wet or corrosive locations to exclude
moisture, dirt, corrosive chemicals, etc.
• Where an incandescent lamp of up to
100 watts is required in a portable hand
lamp

Glass
Globes

Polycarbonate
Globes

Description

Maximum
Lamp Size

Clear Glass,
(Heat Resisting)

100W,
V63
A-23 – 67/8"*

Clear,
Polycarbonate,
Plain

75W,
A-21"*

Features:
• Enclosed and gasketed
• Flexible cord or cable is attached
through a watertight gland in the handle
• Is of rugged construction
• Clamp type guard available
• Provision is made in the lamp receptacle
for a third conductor to ground all noncurrent carrying metal parts

Certifications and
Compliances:

Cat. #

V470

(No Cable Included)

• Weather resistant
• UL Standard: 298

Globe
Length

(Note: CEC/CSA Certified VS Hand Lamps - Eaton's
Crouse-Hinds Canada fixtures only).

Standard Materials:

67/8"
Note:

Guards

Max.
Lamp
Size

Cord
Dia.

Rubber
Cat. #

100W
A-23*

0.125 to
0.625

VS30

Furnished with clear globe, wire guard and 4
rubber bushings.

• Handle – molded rubber
• Globe – clear, plain glass
• Guard – cast aluminum or steel wire

Standard Finishes:
• Handle – natural
• Guard – zinc plated

Description

Size

Steel Wire

67/8" Globe VS97

Cat. #

Size Ranges:

8L

Lamp Receptacle
(medium base)

• Up to 100 watt, A-23 lamp
• 0.250 to 0.625 cord O.D.

Description

Size

Composition
keyless

660W,
GS156
600V

Cat. #

Cord Gland Bushings

Description Size
Rubber

0.125 to 0.250 Cord
0.250 to 0.375 Cord
0.375 to 0.500 Cord
0.500 to 0.625 Cord

Cat. #
BUSH92
BUSH93
BUSH94
BUSH05

*Will take lamps with maximum dimensions of 61/2" long
and 27/8" diameter.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1183

1184-1185.qxp

12/16/2013

8L

7:05 PM

Page 1184

EVH Portable Hand Lamp

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1 & 2, Group G
Cl. III
Cl. I, Zone 1 IIB

Applications:
EVH106 is used:
• As a portable hand lamp in hazardous
areas
• In inspecting aircraft wing tanks, vats,
process vessels, fuel tanks, etc.

Features:
• Pressure connector terminals for
portable cord
• Lightweight – 41/4" lbs.
• Designed for rough service – swivel
hook, ease in relamping

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 and 2, Groups C, D –
100 watts max.
Class I, Zone 1 IIB
Class II, Division 1 and 2, Group G – 75
watts max.
Class III – 75 watts max.
• UL Standard: 781
• CSA Standard: C22.2 No. 137

Standard Materials:

Ordering Information

• Guard and globe holder – copper-free
aluminum
• Handle – molded phenolic composition
• Globe – glass, heat- and impact-resistant

Type

Cord Dia.

EVH106

Model M10

0.375 to 0.625

Replacement Parts

Standard Finishes:
• Natural

8L

Cat. #

Size Ranges:

Description

Cat. #

Guard and globe assembly
Handle assembly (including lampholder)
Cord connector assembly
Lampholder only

EVH606
EVH607
EVH605
EVH:05-279-A

• #16 – 3 type SO cord/cable is to be
used (not supplied)

Capacity Ranges:
• 50 to 100 watt, A-21
• Max. volts – 250 VAC

Temperature Performance Data:
(based on 40°C Ambient)
Class I, Groups C, D
Class II, Group G
Class III

T3C
T3C
T3C

Note: See Section 2P of this catalog for suitable male plug.
1184

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1184-1185.qxp

12/16/2013

7:05 PM

Page 1185

Portable Floodlights

Cl. I, Div. 1 and 2, Groups C, D
Cl. I, Zone 1 II(B) A

8L

Incandescent
Applications:

Standard Materials:

RCDER Portable Incandescent
Luminaires provide general illumination
in locations having hazardous
atmospheres, such as:
• Oil refineries
• Oil and gasoline loading docks
• Aircraft servicing docks and shelters
• Distilleries
• Paint manufacturing plants
• Pumping stations
• Other Class I, Groups C and D
locations

• Body – copper-free aluminum
• Lens – glass, heat- and impact-resistant

RCDER-6

RCDER-10

Cat. No.
44655B

Cat. No.
47283A

Standard Finishes:
• Natural

Size Ranges:
• Take cable with O.D. of 0.375" to
0.500"

Capacity Ranges:
• RCDER-6 – 150 watt, PAR38 or R40;
300 watt, R40 (medium base)
• RCDER-10 – 500 watt, PAR64 (Ext. Mog
End Prong)

Features:
• Wheel base
• Carrying handle
• Adjustment allows rotation of 75°
vertically
• Locking screws hold housing firmly
in position
• Door which threads into housing
includes heat- and impact-resistant
lens; door has notches or
projections for ease of removing or
tightening
• Factory-sealed

Ordering Information:
After identifying the hazardous area, select
the model of luminaire required for that
area. Then from the photometric data,
select appropriate Cat. No. based on type
of mounting desired (Example: RCDER-10
No. 47283A).

Certifications and
Compliances:

8L

• NEC/CEC:
RCDER – Class I, Division 1 and 2,
Groups (C), D; Class I, Zone 1 II(B) A
(see photometric data listing)
• UL Standard: 844
• CSA Standard: C22.2 No. 137 (RCDER6 only)
(Note: CEC/CSA Certified RCDER6 - Eaton's CrouseHinds Canada luminaires only).

Temperature Performance Data:
(based on 40°C Ambient)
RCDER-6
RCDER-10

150W

300W

T3B

T2B

500W
T3C

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1185

1186-1187.qxp

12/16/2013

7:05 PM

Page 1186

Portable Mounted Lights

8L

Photometric Data
Dimensions and Weights
RCDER
Photometric Data:
Beam Spread
Lamp Watts
and Type
RCDER-6
150 Watt
PAR38 Flood
150 Watt
PAR38 Spot
300 Watt
R40 Flood

Location

Hor.

Vert.

Beam
Lumens

Av. Max.
Candle Power

Class I,
Groups C, D
(Zone 1 IIB)

60°

60°

1690

4000

28°

28°

1200

11500

123°

123°

3200

1950

60°

60°

3100

8900

19°

14°

3000

110000

35°

19°

3300

37000

55°

32°

3400

13000

Class I,
Groups D
(Zone 1 IIA)

300 Watt
R40 Spot
RCDER-10
500 Watt, PAR64
(500 PAR64/NSP)

Class I,
Group D

500 Watt, PAR64
(500 PAR64/MFL)
500 Watt, PAR64
(500 PAR64/WFL)

(Zone 1 IIA)

Dimensions

8L

In Inches:

RCDER-6

RCDER-10

Fixture Weights:
RCDER-6
RCDER-10

1186

Cat. #

Lbs. (Net)

44655
47283

26.0
25.0

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1186-1187.qxp

12/16/2013

7:05 PM

Page 1187

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1 & 2, Groups F, G
Cl. III
Cl. I, Zone 1 IIB
Wet Locations
Marine Locations

EVP Portable H.I.D. Floodlight

8L

Applications:

Key Features

The EVP Portable H.I.D. Floodlight† is
suitable for maintenance or emergency
lighting:
• In areas made hazardous by the
presence of flammable gases and
vapors, combustible dusts, or easily
ignitable fibers and flyings
• In aircraft manufacturing and
maintenance facilities, shipyards,
refueling depots, storage tank cleaning,
railcar manufacturing and maintenance
facilities, refineries, chemical and
petrochemical plants, textile mills, grain
elevators and pharmaceutical plants,
printing operations, wastewater, and
sewage treatment plants
• In any adverse environment where
portable lighting is preferred or required
• In locations where lighting is not
practical
• For task oriented lighting

• Strong spun aluminum • Provides stability, allows
wheel base
fixture to be hung on a wall or
lowered in an inverted position
• Sturdy hand knob
• Tightens to hold position for
steady illumination and easy
aiming
• Plastic rib covered
• Firm, non-slip grip for
handle
transporting fixture
• Aluminum specular
• Directs intense beam for
reflector
better visibility
• Tempered, 3/4" thick
• Heavy duty service
cover glass
• Nitrile rubber O-ring
• Excellent sealing for use in
gasket
wet locations
• Strain relief clamps
• Provides extra protection
against cord damage
• Pre-wired, factory• Saves on installation time and
sealed 100' of 16/3
maintenance costs
type SOW cord
supplied
• Lightweight (25 lbs.)
• Easy to handle when
transporting
• Fixture housing has a • Highly visible for safety
safety yellow finish
precautions

Certifications and
Compliances:
• EVP and EVPG
• NEC/CEC:
Class I, Division 1 & 2, Groups C, D
Class I, Zone 1 IIB
Class II, Division 1 and 2, Groups F, G
Class III
Wet Locations
Marine Locations
• UL Standards: 781, 595, 1572
• CSA Standard: C22.2 No. 137, No. 12

Standard Materials:
Housing – copper-free aluminum
Wheel base – spun aluminum
Handle – plastic rib covered aluminum
Reflector – aluminum
O-ring gasket – Nitrile rubber

Electrical Ratings:
High pressure sodium – (medium base)
• 70, 100, & 150 watt
• 120 volt 60 Hz
Metal Halide – (double end)
• 70 watt
• 120, 277 & 347 volt; 60 Hz

Ordering Information:
Cl. I, Div. 1, Groups C, D
Cl. II, Div. 1, Group F

Cat. #

70 watts HPS, 120 volts
100 watts HPS, 120 volts
150 watts HPS, 120 volts
70 watt MH, 120 volts
70 watt MH, 277 volts
70 watt MH, 347 volts

EVP4070
EVP4100
EVP4150*
EVP9070
EVP9070/277
EVP9070/347

Note:

Cl. I, Div. 1, Groups C, D
Cl. II, Div. 1, Groups F, G
Cl. III

Cat. #

100 watts HPS, 120 volts
70 watt MH, 120 volts
70 watt MH, 277 volts
70 watt MH, 347 volts

EVPG4100
EVPG9070
EVPG9070/277
EVPG9070/347

Fixtures for grain dust applications have a special limiting device to prevent the fixture head from being positioned
in an upright position limiting dust build-up.

Temperature Performance Data:
Class I, Division 1

Class II, Division 1

Cat. #

Max.
Ambient °C

T-Rating

Groups

T-Rating

Groups

EVP4070
EVP4100
EVP4150
EVP9070
EVPG4100
EVPG9070

40
40
25
40
40
40

T4A
T4A
T3C
T4
T4A
T4

C, D
C, D
C, D
C, D
C, D
C, D

T3
T3
—
T3
T3C
T4

F
F
—
F
F, G
F, G

8L

•
•
•
•
•

Benefits

Fixture Weight:
• 25.5 lbs.

Photometric Data:

EVP4070

†EVP fixtures are not supplied with plug.
*Class II not available.

EVP4100
Degree from beam axis

EVP4150

Dimensions: 121/2" D × 131/8" W × 157/8" H
www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1187

1188-1189.qxp

12/16/2013

8L

7:05 PM

Page 1188

EVH Fluorescent
Hand Lamps & Work Lights

Cl. I, Div. 1 and 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Cl. I, Zone 1 IIB

Applications:
Portable hand lamps and work lights can be used:
• In areas made hazardous by the presence of flammable gases and
vapors, combustible dusts, or easily ignitable fibers and flyings
• In aircraft manufacturing and maintenance facilities, shipyards,
refueling depots, storage tank cleaning, railcar manufacturing and
maintenance facilities, refineries, chemical and petrochemical
plants, textile mills, grain elevators, pharmaceutical plants, sewage
treatment plants, and wastewater treatment plants
• During plant 'shut downs' for maintenance and installation
requirements
• In any adverse environment where portable lighting is preferred or
required
• In locations where fixed lighting is not practical
• For task oriented lighting
• For emergency lighting applications
• When inspecting aircraft wing tanks, vats, process vessels, fuel
tanks, etc.

Features:
• Built-in metal reflector which eliminates glare and blinding,
focusing all light on subject
• Protected by patented shock absorbers to withstand rough usage
• Enclosed ballast, remote from light source for easier handling and
maneuverability
• Special rubber compound bumper guards and end caps combined
with cast guard and metal rods, protecting against damage from
falling objects, bumping, or dropping
• Luminaires come complete with lamp(s) and cord
• The new EVH2625E and EVH2650E incorporate an electronic
ballast in the handle for efficiency, cool operation, and easy
handling

8L

Certifications and Compliances:
• NEC: Fluorescent Work Lights (15 watt units)
Class I, Division 1 and 2, Group D
Class I, Zone 1 IIB
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEC: Fluorescent Hand Lamps (13 and 26 watt units)
Class I, Division 1 and 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• FM: Classification 3615
• CSA: C22.2

Temperature Performance Data:
Based on 40°C Ambient Temperature
Cat. #

Class I, Div. 1
T-Rating
Groups

Class II, Div. 1
T-Rating
Groups

EVH1525
EVH1550
EVH1325
EVH1350
EVH2625
EVH2650
EVH1325 IB
EVH1350 IB
EVH2625E
EVH2650E

T5
T5
T5
T5
T3
T3
T5
T5
T6
T6

T5
T5
T5
T5
T3
T3
T5
T5
T6
T6

D
D
C,
C,
C,
C,
C,
C,
C,
C,

D
D
D
D
D
D
D
D

E,
E,
E,
E,
E,
E,
E,
E,
E,
E,

F,
F,
F,
F,
F,
F,
F,
F,
F,
F,

Ordering Information:
EVH Fluorescent Work Lights
Cord
Line Voltage Watts Length (ft.) Lamp Type
60 Hz
15
25 ft.
F15T8
120
15
50 ft.
F15T8
120

Cat. #
EVH1525
EVH1550

EVH Fluorescent Hand Lamps (with Magnetic
Ballast in Cord)

Standard Materials:

Cord
Watts Length (ft.) Lamp Type

Cat. #

13
13
26
26

25
50
25
50

ft.
ft.
ft.
ft.

F13TT
F13TT
F26DTT
F26DTT

EVH1325
EVH1350
EVH2625
EVH2650

13
13
26
26

25
50
25
50

ft.
ft.
ft.
ft.

F13TT
F13TT
F26DTT
F26DTT

EVH1325/220
EVH1350/220
EVH2625/220
EVH2650/220

Options:

Line Voltage
60 Hz
120
120
120
120
50 Hz
220
220
220
220

Description
Suffix
An isolated ballast is available on the EVH 13 Watt hand lamps
for additional protection
IB

EVH Fluorescent Hand Lamps (with Electronic
Ballast in Handle)

• Body and inline ballast unit – aluminum
• Tube shield – annealed glass
• Bumper guards – rubber

Standard Finishes:
•
•
•
•

Aluminum body – white epoxy (hand lamps)
Aluminum body – natural (work lights)
Inline ballast unit – natural
Rubber bumper guards – safety yellow

Size Ranges:

Cord
Line Voltage Watts Length (ft.) Lamp Type
Cat. #
60 Hz
26
25 ft.
CF26DD/E/841 EVH2625E
120
26
50 ft.
CF26DD/E/841 EVH2650E
120

• Supplied with 18 / 3 SOW cord (25 ft or 50 ft)

Electrical Ratings:
• 13 to 26 Watts
• Max. volts 220VAC

1188

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

G
G
G
G
G
G
G
G
G
G

Copyright© 2013 Eaton’s Crouse-Hinds Business

50
50
50
50

1188-1189.qxp

12/16/2013

7:05 PM

Page 1189

8L

EVH Fluorescent
Hand Lamps & Work Lights

Dimensions
In Inches:
Work Light

Hand Lamp (Magnetic Ballast Handlamps Only)

8L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1189

1190-1191.qxp

12/16/2013

7:05 PM

Page 1190

8L

8L

1190

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1190-1191.qxp

12/16/2013

7:05 PM

Page 1191

Exit Signs and
Emergency Luminaires
Hazardous and Non-hazardous

9L

Description

Page No.

Exit Signs
EXL Series
EVLPF(B)-EXD
DMVF(B)-EXD
Ex-Lite
CCH UX Series

see pages 1192–1193
see page 1194
see page 1195
see page 1207
see page 1208

Light-Pak™ – Emergency Lighting Systems
ELPS Series
N2LPS Series

see page 1196
see pages 1198–1200

Remote Luminaire Heads
EVLA
N2RF

see page 1196
see pages 1198–1200

Compact Fluorescent Emergency Luminaires
CPMVFB
DMVFB
EVLPFB

see pages 1201–1202
see pages 1203–1204
see pages 1205–1206

9L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1191

1192-1193.qxp

12/16/2013

9L

7:06 PM

Page 1192

EXL Explosionproof Exit Sign

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Zone 1 IIB
Cl. II, Div. 1, Groups E, F, G

Factory-sealed
Applications:

Ordering Information:

EXL Exit Signs are used:
• In locations deemed hazardous due to
the presence of flammable vapors or
gases, or combustible dusts
• In any building or enclosed area where
people work – where illuminated exit
signs are required
• To provide distinct, highly visible exit
marking
• To indicate the direction of travel to exits

When ordering an EXL Series Exit Sign,
you will need to specify:
(A) Voltage (120VAC or 120VDC)
(B) Mounting (Wall, End Bracket, or
Pendant)
(C) Exit Sign Designation
All units come standard with 3/4" hubs and
exit signs with red lettering and white
background. Complete catalog numbering
is as follows:

Lamp Wattage:

EXL (A) 2 (B) (C)
(A) Voltage: 120VAC ............ leave blank
120VDC .......................... D
(B) Mounting: Wall................................. 1
End Bracket.................... 2
Pendant .......................... 3
(C) Exit Sign Designation:
A
Single Face (Wall Mount)
AA
Double Face (End Bracket
& Pendant)
AB
Double Face, one side
arrowhead right, the other
no arrowhead (End Bracket
& Pendant)
AC
Double Face, one side
arrowhead left, the other no
arrowheads (End Bracket &
Pendant)
AD
Double Face, one side
arrowhead both ends, the
other no arrowheads (End
Bracket & Pendant)
B
Single Face, arrowhead
right (Wall Mount)
BC
Double Face, one side
arrowhead right, the other
arrowhead left (End Bracket
& Pendant)
BD
Double Face, one side
arrowhead both ends, the
other arrowhead right (End
Bracket & Pendant)
C
Single Face, arrowhead left
(Wall Mount)
CD
Double Face, one side
arrowhead both ends, the
other arrowhead left (End
Bracket & Pendant)
D
Single Face, arrowhead
both ends (Wall Mount)
DD
Double Face, both sides
arrowhead both ends (End
Bracket & Pendant)

• Two 60 watt, 60T10 clear lamps for AC units
• Two 25 watt, 25T10 clear lamps for DC units
• Lamps not included with luminaire

Mounting
Type

Sign Panel
Description

Hub
Size (In.)

AC
Cat. #

DC
Cat. #

Wall
End Bracket
Pendant

Single face
Double face
Double face

3

Electrical Ratings:

/4
/4
3
/4

EXL21A
EXL22AA
EXL23AA

EXLD21A
EXLD22AA
EXLD23AA

Features:
• Two incandescent lamps (not included)
wired in parallel – to provide extra
margin of light source reliability
• Solid state circuit for extended lamp life
in AC units
• Six inch red letters on white acrylic sign
panel make word "exit" stand out boldly
and clearly
• Edge lighting characteristic of sign panel
makes visibility excellent at all lighting
levels
• Factory-sealed explosionproof housing
• Pendant, wall, and end bracket mounts
provide universal installation options
• Impact-resistant acrylic sign panel needs
no guard – makes cleaning easy
• Internal rectifier extends lamp life
beyond 1,000-hour rated life – reduces
relamping cost
• Relamping tool provided

9L

Certifications and
Compliances:
• NEC:
Class I, Groups C, D
Class II, Groups E, F, G
• UL Standard: 844
• NFPA Life Safety Code No. 101-1991

Standard Materials:
• Body – copper-free aluminum
• Sign panel – acrylic

Conduit Entrance:
• 3/4" hubs

• 120VDC or 120VAC operation

Temperature Performance
Data:
(for both AC & DC operation):
Ambient
Temp. (°C)
25
40
1192

Class I (C, D)
Class II (E, F, G)

Supply
Wire °C

T3C
T3C

150°C

www.crouse-hinds.com

US: 1-866-764-5454

Pendant Style

End Bracket Style

Wall Style

3

Options:
Description
Suffix
Exit signs with green lettering on white background........................................................
GN
Unit provided with epoxy powder coat............................................................................. S752
277VAC – (Order ECT413 Transformer Separately)

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1192-1193.qxp

12/16/2013

7:06 PM

Page 1193

EXL Explosionproof Exit Sign

9L

Factory-sealed
Dimensions
Dimensions
In Inches:

Wall Style

Pendant Style

9L

End Bracket Style

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1193

1194-1195.qxp

9L

12/16/2013

7:06 PM

Page 1194

Cl. I, Div. 1, Groups B (suffix GB), C, D
Cl. I, Zone 1, Groups IIB + H2
(GB suffix), IIB
Cl. II, Div. 1, Groups E, F, G; Class III,
Simultaneous Presence

EVLPF(B) – Exit Sign
Fluorescent Luminaire

Applications:
EVLPF(B)-EXD Exit Signs are used:
• In any building or enclosed area where
people work – where illuminated exit
signs are required
• To provide distinct, highly visible exit
marking
• To indicate the direction of travel to exits
• In locations deemed hazardous due to
the presence of flammable vapors,
gases, or combustible dusts

Features and Benefits:
• Six inch red letters on white glass sign
panel make the word "EXIT" stand out
boldly and clearly
• Lightweight copper-free aluminum
housing with powdered epoxy finish
• All exterior hardware is corrosionresistant stainless steel
• Three mounting arrangements: pendant,
ceiling, and wall bracket
• Integral ballast
• High power factor (90%+) ballasts
• Easier assembly, installation, and
maintenance
• Outdoor, hose down, marine and
corrosive environments suitable
• Ideal for adverse environments typical of
industrial facilities
• Ground wire for safety
• Optional battery back-up for operation
during power outage

Marine & Wet
Locations
3, 3R, 4, 4X;
IP66

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 1, Groups B (GB
suffix), C, D
Class I, Zone 1, Groups IIB + H2 (GB
Suffix), IIB, IIA
Class II, Class III & Simultaneous
Presence (Class I and Class II)
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137

Standard Materials:
• Mounting modules, cover, ballast
housing, globe holder – copper-free
aluminum
• Globe – heat- and impact-resistant glass
• Exterior hardware – stainless steel

Ratings (Electrical/Size):
Sources/wattage:
• 52W (2-26W lamps)
• 120-277V, 50-60 Hz
• 120V, 60 Hz
• 347V, 60 Hz
Conduit entries:
• 3/4", 1" NPT – pendant, wall bracket,
ceiling

Standard Finishes:
• Copper-free aluminum – Corro-free™
powdered epoxy

Options:
Description
Group B suitability
Factory assembled with lamps

Suffix
GB
FA

9L

About the Battery:
• Bodine fluorescent battery pack ballasts
are UL component recognized
• Sealed, maintenance-free, high
temperature nickel cadmium
• Solid state chargers are sealed inside
the ballast case
• 90 minute illumination time
• 10-year life expectancy
• 2-year full warranty
• During emergency use 1 lamp has
continuous operation
• Red indicator light indicates the battery
is charging
• Wiring instructions for a "Push-to-Test"
button is supplied with the luminaire

Ordering Information:
Supply
Mounting Voltage
Type
Volts/Hertz

Fluorescent Cat. #

Pendant

120–277V / 50–60 Hz EVLPFA02520/UNV EXD EVLPFBA02520/UNV EXD
120V / 60 Hz (Canada)
EVLPFBA02520/120CAN EXD
347V / 60 Hz
EVLPFA02520/347 EXD EVLPFBA02520/347 EXD

Ceiling

120–277V / 50–60 Hz EVLPFCX02520/UNV EXD EVLPFBCX02520/UNV EXD
120V / 60 Hz (Canada)
EVLPFBCX02520/120CAN EXD
347V / 60 Hz
EVLPFCX02520/347 EXD EVLPFBCX02520/347 EXD

Wall

120–277V / 50–60 Hz EVLPFBX02520/UNV EXD EVLPFBBX02520/UNV EXD
120V / 60 Hz (Canada)
EVLPFBBX02520/120CAN EXD
347V / 60 Hz
EVLPFBX02520/347 EXD EVLPFBBX02520/347 EXD

Energy Savings:
• Less wattage used with compact
fluorescent lamps compared to
equivalent incandescent lamps providing
the same light output

1194

www.crouse-hinds.com

US: 1-866-764-5454

Fluorescent with
Battery Back-up Cat. #

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1194-1195.qxp

12/16/2013

7:06 PM

Page 1195

DMVF(B) – Exit Sign
Fluorescent Luminaire

Applications:
DMVF(B) Exit Signs are used:
• In any building or enclosed area where
people work
• Where illuminated exit signs are required
• To provide distinct, highly visible exit
markings
• To indicate the direction of travel to exits
• In locations deemed hazardous due to
the presence of flammable vapors or
gases, or combustible dusts

Features:
• Six inch letters on white glass sign panel
make the word "exit" stand out boldly
and clearly
• Housings made of die-cast copper-free
aluminum (less than 0.4 of 1% copper)
for strength and resistance to corrosion
• Mounting module equipped with integral
hub set-screws for vibration resistance
(ceiling and pendant mounts)
• Hubs are provided with an integral
conduit stop and bushing to help prevent
damage to field wiring during installation
• Epoxy powder finish and stainless steel
external hardware for resistance to
corrosion
• Long life gaskets which provide seals
between mounting module, housing, and
globe assembly
• Grounding wire for safety
• Cool operating design
• Optional emergency battery back-up
operation during power outage

About the Battery:

Energy Savings:
• Less wattage used with compact
fluorescent lamps compared to
equivalent incandescent lamps providing
the same light output

Cl. II, Groups E, F, G,
Cl. III & Simultaneous Presence
Marine & Wet Locations
3, 3R, 4X; IP66

9L

Certifications and
Compliances:
• NEC and CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III & Simultaneous
Presence
(Class I, Division 2 and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844, 2279 Hazardous (Classified)
Locations
1598 Luminaires
1598A Marine Luminaires
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15

Standard Materials:
• Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%)
• Exterior hardware – stainless steel
• Globe – heat- and impact-resistant
internally fluted glass

Standard Finishes:
• Aluminum – gray epoxy powder coat
• Krydon material – high reflectance white
• Stainless steel – natural

Options:
Description
Suffix
Lamps supplied with exit sign...............................................
S714
Top hat with stainless steel threaded insert..........................
S806
Restricted breathing construction..........................................
S826
Class I, Division 2 & Zone 2 suitability
Cooler operating temperatures (T-Numbers)
Certified for IEC Zone 2......................................................... S826TB
Furnished with:
Terminal Block
Crimp Terminals
Dedicated voltage ballasts (no MT, DT or TT)

9L

• Bodine fluorescent battery pack ballasts
are UL component recognized
• Sealed, maintenance-free, high
temperature nickel cadmium
• Solid state chargers are sealed inside the
ballast case
• 90 minute illumination time
• 10-year life expectancy
• 2-year full warranty
• During emergency use 1 lamp has
continuous operation
• A red indicator light indicates the battery
is charging
• Wiring instructions for a "Push-to-Test"
button is supplied with the fixture

Cl. I, Div. 2; Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Electrical Rating Ranges:
•
•
•
•

52 Watt
120–277V, 50–60 Hz
120V, 60 Hz
347V, 60 Hz

Ordering Information:
Mounting
Type

Supply
Voltage
Volts/Hertz

Fluorescent Cat. #

Pendant

120–277V / 50–60 Hz
120V / 60 Hz (Canada)
347V / 60 Hz

DMVF2C052G/UNV EXD

Ceiling

120–277V / 50–60 Hz
120V / 60 Hz (Canada)
347V / 60 Hz

Wall

120–277V / 50–60 Hz
120V / 60 Hz (Canada)
347V / 60 Hz

DMVF2TW052G/UNV EXD DMVFB2TW052G/UNV EXD
DMVFB2TW052G/120CAN EXD
DMVF2TW052G/347 EXD DMVFB2TW052G/347 EXD

www.crouse-hinds.com

US: 1-866-764-5454

DMVF2A052G/UNV EXD

Fluorescent with
Battery Back-up Cat. #

DMVF2A052G/347 EXD

DMVF2C052G/347 EXD

CAN: 1-800-265-0502

DMVFB2A052G/UNV EXD
DMVFB2A052G/120CAN EXD
DMVFB2A052G/347 EXD
DMVFB2C052G/UNV EXD
DMVFB2C052G/120CAN EXD
DMVFB2C052G/347 EXD

Copyright© 2013 Eaton’s Crouse-Hinds Business

1195

1196-1197.qxp

12/16/2013

9L

7:06 PM

Page 1196

ELPS Light-Pak™
Emergency Lighting
System

Applications:
ELPS Series Emergency Lighting Systems
are used:
• To provide safe, reliable illumination
indoors or outdoors to designated areas
during failure or interruption of power to
the normal lighting system
• In areas made hazardous by the
presence of flammable gases and
vapors, combustible dusts, or easily
ignitible fibers and flyings
• In areas where corrosion, vibration,
moisture, dirt, and rough usage may be
encountered
• Where required by the National Electrical
Code®, the Life Safety Code, or other
codes
• In refineries, chemical and petrochemical
facilities, grain processing, handling or
storage facilities, manufacturing plants,
wastewater treatment facilities, and
other areas where safe, reliable,
hazardous area emergency lighting is
needed

9L

Features:
• Compact factory-sealed luminaire
assemblies are each furnished with a 12
watt tungsten-halogen lamp and inner
reflector for appropriate photometrics in
hazardous areas
• Luminaire assemblies are fully adjustable
and lockable on two axes to provide
flexible and consistent light aiming
capabilities
• Luminaire lens ring is threaded for easy
relamping and locks in place with hex
head set-screw; will not loosen due to
vibration
• Ground joint cover with external flange
design permits large opening and easy
access to internal components; stud
bolts in diagonally opposite corners of
body ease cover removal and installation
• Neoprene cover gasket seals out
moisture for superior protection of
internal components against wetness
and corrosion
• Lightweight, compact size, and
mounting feet ease installation and allow
placement in confined areas
• Two 1" NPT drilled and tapped conduit
openings, with plugs, are standard, for
choice of top or bottom feed
• Factory-installed PUSH-TO-TEST
pushbutton enables easy testing of
system
• MAIN POWER ON pilot light indicates
AC power is being supplied to the
battery charger; pilot light jewel is
threaded for easy lamp replacement
• Stainless steel drain minimizes moisture
collection; stainless steel breather with
aluminum cap provides ventilation,
minimizes moisture collection

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Div. 1 & 2, Groups B, C, D
(with suffix GB)
Cl. II, Div. 1, Groups E, F, G
Cl. III

• CID 101 corrosion inhibitor device is
provided with each ELPS system to help
protect electrical components and
connections
• Rugged, long-life, maintenance-free,
nickel cadmium battery provides 30
watts of power for the required 11/2 hours
• Solid state battery charger for long life
and reliable service prevents deep
discharge by automatically
disconnecting luminaires from battery
• Terminal block facilitates field wiring
connections
• Instruction sheet and maintenance
record card provided with unit in a
protective plastic envelope
• A time delay is standard; time delay is
preset at factory for 5 minute delay but
can be field set for 5 seconds or 15
minutes, thus allowing HID type lamps
time to restrike and reach desired
illumination levels
• Solid state battery charger will accept
120, 220/240 or 277 VAC, 50/60 Hz

Certifications and
Compliances:
• NEC:
Class I, Groups B, C, D
Class II, Groups E, F, G
Class III
Simultaneous Presence
• NEMA: 3R, 12 (ELPS power supply)
• Suitable for wet locations (EVLA fixtures)
• Marine (EVLA fixtures)
• UL Standard:
844 – Electric Luminaire – Hazardous
Locations
924 – Emergency Lighting and Power
Equipment
1203 – Explosionproof and DustIgnitionproof Electrical Equipment
• Life Safety Code:
Section 5-9 (Emergency Lighting)
• Suitable for Wet Locations
• NEMA 3, 3R, 12
• Marine

Standard Materials:
• Power supply enclosure and luminaire
assembly – copper-free aluminum (less
than 0.4 of 1% copper)

Standard Finishes:
• Power supply enclosure and fixture
assemblies – powder coat epoxy paint
finish

Electrical Ratings:
• Power Supply:
Input:
120, 220/240, 277 VAC, 50 or 60 Hz
0.5 Amps Maximum
Output:
12 VDC
UL listed for 28 watts for 11/2 hours at 0° –
40°C
• Luminaires:
Voltage: 12 VDC
Lamp Type: #789, miniature
Tungsten halogen, G4, 2-pin, 14 watt

Options:
Description
Suffix
• Remote mounted lamp head and arm .... EVLA12
• Key operated disconnect switch
as part of the ELPS502
emergency light system .......................... S794
• Keyless operated designated
disconnect switch as part of the
ELPS502 emergency light system .......... S854

Ordering Information:
Description

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Cat. #

• Standard unit with
ELPS502†
adjustable heads............
• Replacement power
interior, includes circuit
ELPS K50
board and battery pack
• Power supply .................
ELPS50†
• Lamphead and arm .......
EVLA12†
• Exit sign, double sided
ELPS502 EXD
with EVI, red letters........
• Exit sign, double sided
ELPS502 EXD GN
with EVI, green letters....
• Exit sign, single or
double sided with
Group B EVA,
ELPS502 EXD GB
red letters.......................
• Exit sign, single or
double sided with
Group B EVA, green
letters ............................. ELPS502 EXD GB GN
• Exit sign, single sided
with EVI, red letters........
ELPS502 EXS
• Exit sign, single
sided with EVI,
green letters ...................
ELPS502 EXS GN

†Base unit comes standard with Class I, Division 1, Group B.

1196

Cl. I, Zone 1
Simultaneous Presence
Wet Locations
NEMA 3, 3R, 12

Copyright© 2013 Eaton’s Crouse-Hinds Business

1196-1197.qxp

12/16/2013

7:06 PM

Page 1197

ELPS Light-Pak™
Emergency Lighting System

Temperature Performance Data
Photometric Data
Dimensions and Weights

Temperature Performance Data:
Cat. #
Class
Maximum Ambient Temperature 55°C
I
II*
EVLA12
III*

9L

Photometric Data:

T-number
T4A
T3B
T3B

Maximum Ambient Temperature 40°C
ELPS EVI
ELPS EVA

T3C
T4
T3C
T4

*For Class II and Class III applications, fixtures must not be aimed more than 30° above
horizontal (see diagram below).

Dimensions
In Inches:

9L

Unit Net Weights:
• ELPS502 complete emergency lighting system – 50 lbs.
• ELPS50 power supply – 40 lbs.
• EVLA12 luminaire assembly – 5 lbs.

Status Indication:
LED Status

Meaning of the Indication
AC power is removed from the circuit

•

Steady light (no blinking)

Fully charged

•

Light blinks once

Charging

••

Light blinks twice

Battery failure

Light blinks three times
Light blinks four times

Circuit failure
Lamp failure

•••
••••

www.crouse-hinds.com

Condition
No light

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1197

1198-1199.qxp

12/16/2013

7:06 PM

Page 1198

N2LPS LIGHT-PAK™
Emergency Lighting System

9L

Applications:
LED N2LPS Light-Pak™ emergency lighting
systems are used:
• To provide reliable illumination for
egress areas during failure or
interruption of power to the normal
lighting system
• In areas where flammable gases or
vapors may become present due to
abnormal, unusual, or accidental
conditions
• In manufacturing plants, refineries,
petrochemical and chemical plants,
waste and sewage treatment facilities,
oil terminals, food processing facilities,
breweries, and other industrial
manufacturing or process industry
facilities subject to wet or corrosive
conditions
• To illuminate machinery or panels during
a loss of AC power
• Where moisture, dirt, dust, or corrosion
will limit the life and reliability of ordinary
emergency lighting systems
• Where required by the National
Electrical Code®, the Life Safety Code®
or other applicable codes
• Outdoor applications

9L

Features:
• Compact, factory-assembled luminaire
featuring LED lamps for improved lumen
performance, on-time, and lamp life
• Nonmetallic, enclosed, and gasketed
housing provides corrosion protection in
the most extreme environments
• Durable and marine rated LED lamp
head assemblies provide protection
against water ingress, corrosion, and
impact
• High temperature rated nickel cadmium
battery for reliable operation up to 55ºC
ambient
• Solid state battery charger for long life
and reliable battery operation prevents
deep discharge by automatically
disconnecting the battery from the
luminaire
• Factory-installed "push-to-test" button
• Self-test, monitoring, and diagnostics
reduce costly maintenance checks
• Remote luminaire head assemblies (one
or two) are available for mounting of
luminaire heads away from main power
system
• Stainless steel drain minimizes moisture
collection
• Standard battery disconnect switch
(Krydon® unit)

1198

www.crouse-hinds.com

US: 1-866-764-5454

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 2
Cl. II, Div. 2, Groups F, G
Wet Locations, Marine
NEMA 3, 3R, 4X
Ambient 0ºC to 55ºC

Certifications and
Compliances:
NEC/CEC:
• Class I, Division 2, Groups B, C, D,
Zone 2
UL Standards:
• 1598A (Supplemental Requirements for
Luminaires for Installation on Marine
Vessels)
• 924 (Emergency Lighting and Power
Equipment)
• 844 (Electric Luminaires Hazardous
Locations)
CSA Standards:
• C22.2 No. 141-M1985 unit equipment
for emergency lighting
• C22.2 No. 137-M1981 non-incendive
electrical equipment for use in Class I,
Division 2 hazardous locations
• Life Safety Code NFPA101® –
Section 5-9 (Emergency Lighting)
• Marine wet locations suitability, Type 4X

Standard Materials:
• Power supply and remote luminaire
enclosures – Krydon® fiberglassreinforced polyester
• LED lamp head assembly – epoxy
powder coated stainless steel
• Exterior hardware – nylon, plastic
coated, and stainless steel
• Cover gasket – Hypalon® synthetic rubber

Temperature Performance
Data:
Based on 55°C ambient
Class I,
Cat. #
Division 2
N2LPS (all)
N2RF (all)

40ºC - T5;
55ºC - T4A
T5

Class II,
Division 1

Electrical Ratings:
• Power supply –
Input: 120, 220, 230, 240, or 277 VAC,
50 or 60 Hz; 9 watts max.
Output: 18 watts max. at 12 VDC
• Luminaire heads –
Voltage: 12 VDC; Lamp: 3 watt LED
Total lumen output: 80

Unit Net Weights:
•
•
•
•

N2LPS12222 – 16 lbs.
N2LPS12220 – 12 lbs.
N2RF1221 – 8 lbs.
N2RF1222 – 9 lbs.

Options:
Description
Suffix
55°C suitability . . . . . . . . . . . . . . . . . S904

T6
T6

Note:

Ambient temperature at which the Light-Pak
system is rated is 0°C to 55°C. Operation at
temperatures outside this range will affect the
battery life and/or charging performance.

Note:

Battery time in emergency mode is 90 minutes.

National Electrical Code and Life Safety Code are
registered trademarks of the National Fire Protection
Association, Inc.
Noryl is a registered trademark of General Electric
Company.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1198-1199.qxp

12/16/2013

7:06 PM

Page 1199

N2LPS LIGHT-PAK™
Emergency Lighting System

9L

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 2
Cl. II, Div. 2, Groups F, G
Wet Locations, Marine
NEMA 3, 3R, 4X
Ambient 0ºC to 55ºC

Ordering Information:
Description

Cat. #

28 watt, 12 volt power supply assembly with two 3 watt LED lamp heads
28 watt, 12 volt stainless steel power supply assembly with two 3 watt LED lamp heads
28 watt, 12 volt power supply assembly less luminaire heads
Remote luminaire assembly with one 3 watt LED lamp head
Remote luminaire assembly with two 3 watt LED lamp heads
28 watt, 120V LED Light-Pak with single sided exit sign**
28 watt, 277V LED Light-Pak with single sided exit sign**
28 watt, 120V LED Light-Pak with double sided exit sign**
28 watt, 277V LED Light-Pak with double sided exit sign**

N2LPS12222
N2LPS12222 SS
N2LPS12220*
N2RF1221*
N2RF1222*
N2LPS12222/120
N2LPS12222/277
N2LPS12222/120
N2LPS12222/277

EXS DR0391734
EXS DR0391734
EXD DR0391734
EXD DR0391734

*Not cUL approved. UL Listed only.
**Exit sign operates in both normal and emergency mode.

Note: Up to four (4) remote LED lamp assemblies can be connected to the N2LPS12222. Up to six (6) remote LED lamp assemblies can be
connected to the N2LPS12220.

Wire Sizing for Remote Installation:
For Copper Wire –
Running Distance† (ft.) Between Power Supply and Remote Luminaire
Load In Watts

Load In Watts

Wire Size

8

16

24

32

Wire Size

8

16

24

32

16 AWG
14 AWG
12 AWG

26
42
66

13
21
33

6
10
16

3
5
8

10 AWG
8 AWG
6 AWG

106
168
270

53
84
135

26
42
67

13
21
33

†Maximum distance to limit line voltage drop to 5%.

Dimensions (N2LPS):
1.1

13.5

9L

16.0

7.5
5.0

13.8
14.5

7.4

18.0

Standard – N2LPS LED Light-Pak™

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1199

1200-1201.qxp

12/16/2013

7:07 PM

Page 1200

N2LPS LIGHT-PAK™
Emergency Lighting System

9L

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 2
Cl. II, Div. 2, Groups F, G
Wet Locations, Marine
NEMA 3, 3R, 4X
Ambient 0ºC to 55ºC

Dimensions (N2LPS):

EXS, EXD Option – N2LPS LED Light-Pak™ with Optional Emergency Exit Luminaire

Dimensions (N2RF):

9.50

9L

9.50

3.83

3.83

7.27

4.38

11.77

Detail Indication Logic:
Status Indication

Status Description

Status Definition

*
*-*
**-**
***-***

No Light
Steady Light (No Blinks)
Light Blinks Once
Light Blinks Twice
Light Blinks Three Times

AC Power Removed from Circuit
Fully Charged
Battery Charging
Battery Failure
Circuit Failure

1200

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1200-1201.qxp

12/16/2013

7:07 PM

Page 1201

CPMVFB Emergency
Compact Fluorescent
Continuous Operation
Champ-Pak™ Luminaires

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence*
Marine & Wet Locations
3, 3R, 4, 4X; IP66
Emergency Lighting

Applications:

Standard Materials:

• Where emergency lighting is required to
permit workers in industrial areas to
safely encounter their surroundings
during power failures
• Where emergency egress lighting is
required, such as: catwalks, walkways,
tunnels, doorways, stairs, stairwells,
ramps and aisles
• Indoor and outdoor wall mounting or
vertical surface mounting where minimal
luminaire depth is required in:
– Manufacturing plants and heavy
industrial facilities
– Industrial process facilities such as
refineries, chemical, petrochemical,
pharmaceutical, and platforms
– Waste or sewage treatment plants
– Offshore, dockside, and harbor
installations
• For security and safety lighting in
industrial facilites for lighting of loading
docks, tunnels, and stairways
• For marine, wet location, hose down,
and corrosive environments

• Luminaire housing and door frame
assembly – copper-free aluminum
• External hardware – stainless steel
• Lens – heat- and impact-resistant
refractor style glass
• Gaskets – silicon rubber
• Reflector – aluminum light sheet
• Wire guard – stainless steel

Features and Benefits:

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III & Simultaneous
Presence
(Class I, Division 2 and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844, 2279 Hazardous (Classified)
Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15

Standard Finishes:
• Aluminum – Corro-free™ epoxy powder coat
• Stainless steel – natural

Options:
Description
Suffix
Restricted breathing construction.................................................................................
S826
Class I, Division 2 & Zone 2 suitability
Cooler operating temperatures (T-numbers)
Certified for IEC Zone 2 (Suffix S826TB)....................................................................... S826TB
Furnished with:
Terminal Block
Crimp Terminals
Dedicated voltage ballasts (no MT, DT or TT)
Factory assembled with lamp installed.........................................................................
FA
Fused - projects ballast and capacitors against abnormal line conditions..................
S658
(Not for use in Canada)
(Not for Marine use)

Electrical Rating Ranges:
•
•
•
•

52 watts
120–277V, 50–60 Hz
120V, 60 Hz
347V, 60 Hz

About the Battery:
•
•
•
•
•
•
•
•
•

9L

• Unique compact shallow profile design
mounts virtually anywhere
• Side hinged cover with two screw
closing for easy installation and
maintenance
• Gray Corro-free™ epoxy powder coat
two-piece housing provides superior
corrosion resistance
• Unique stainless steel wire guard
accessory attaches without any
additional hardware for easy installation
and maintenance
• Glass refractor provides uniform light
distribution to eliminate glare
• Silicon gaskets make luminaire suitable
for NEMA 4X, marine enviroments
• High power factor ballasts (+90%) are
standard, which allow more luminaires
per circuit

9L

Bodine fluorescent battery pack ballasts are UL component recognized
Sealed, maintenance-free, high temperature nickel cadmium
Solid state chargers are sealed inside the ballast case
90 minute illumination time
10-year life expectancy
2-year full warranty
During auxiliary use 1 lamp has continuous operation
A red indicator light indicates the battery is charging
Wiring instructions for a "Push-to-Test" button is supplied with the fixture

Accessories:
Description
Stainless steel wire guard.............................................................................................

Cat. #
P55

*Consult Eaton's Crouse-Hinds.
www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1201

1202-1203.qxp

12/16/2013

7:07 PM

Page 1202

CPMVFB Emergency
Compact Fluorescent

9L

Ordering Information
Dimensions & Weights

Continuous Operation
Champ-Pak™ Luminaires
Ordering Information:
Hub Size

Lamp
Watts

Cat. # for use
with ANSI Lamps

/4 NPT

26

CPMVFB2W026

3

Standard Voltage Ballasts
NEC/UL
120–277V 50–60 Hz
/UNV

Voltage
Suffix

CEC/CSA (cUL)
120V/60 Hz
347V 60 Hz
/120CAN
/347

Dimensions

9L

In Inches:

Net Weights:
Luminaire Less Guard
P55 Guard

1202

www.crouse-hinds.com

18.6 lbs.
0.5 lbs.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1202-1203.qxp

12/16/2013

7:07 PM

Page 1203

DMVFB Emergency
Compact Fluorescent
Continuous Operation
Champ® Luminaires
Applications:
DMVF Series Champ Lighting Luminaires
are used:
• Where emergency lighting is required to
permit workers in industrial areas to
safely encounter their surroundings
during power failures
• Where emergency egress lighting is
required, such as: catwalks, walkways,
tunnels, doorways, stairs, stairwells,
ramps, and aisles
• In areas made hazardous by abnormal
conditions resulting in the presence of
flammable vapors or gases
• In areas made hazardous by the
presence of combustible dusts
• Where combustible dusts and flammable
vapors are present simultaneously
• In marine applications where water spray
and corrosive atmospheres are
considerations
• On installations where vibration and
rough usage are problematic
• Where a cool, efficient light source
is required
• In areas that require lamps to reach full
illumination immediately
• In refineries, chemical and petrochemical
facilities, grain processing, handling or
storage facilities, manufacturing plants,
wastewater treatment plants, sewage
treatment plants, oil terminals, food
processing facilities, breweries, and
any other manufacturing or processing
facility where safe, reliable hazardous
area fluorescent or auxiliary lighting
is needed

• Housings made of die-cast copper-free
aluminum (less than 0.4 of 1% copper)
for strength and resistance to corrosion
• Mounting modules equipped with
integral hub set-screws for vibration
resistance (ceiling, pendant, and quad
mounts)
• Hubs are provided with an integral
conduit stop and bushing to help prevent
damage to field wiring during installation
• Epoxy powder finish and stainless steel
external hardware for resistance to
corrosion
• Long-life gaskets which provide seals
between mounting module, housing,
and optical assembly
• Grounding wire for safety
• Cool operating design
• Optional stainless steel open bottom
guard permits direct access to the globe
for easy relamping
• Battery pack ballast for emergency
lighting

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP66
Emergency Lighting

9L

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
Class I, Zone 2
Emergency Lighting
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844, 2279 Hazardous (Classified)
Locations
1598 Luminaires
1598A Marine Locations
924 Emergency Lighting
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15

Standard Materials:
• Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%)
• External hardware guards – stainless steel
• Reflectors – Krydon® fiberglassreinforced polyester material
• Globe – heat- and impact-resistant
internally fluted glass

Standard Finishes:
• Aluminum – gray epoxy powder coat
• Krydon material – high reflectance white
• Stainless steel – natural

Options:
Description
Suffix
• Restricted breathing
construction................................
S826
-Class I, Division 2 &
Zone 2 suitability
-Cooler operating temperatures
(T-numbers)
• Certified for IEC Zone 2............. S826TB
-Furnished with:
Terminal Block
Crimp Terminals
• Emergency operation only –
Consult Eaton's Crouse-Hinds
• Factory assembled with lamp
installed.......................................
FA
• Fused – to protect ballast
against abnormal line conditions
(not for use in Canada) (not for
marine use).................................. S658
• Lamps supplied with luminaire...
S714
• Top hat with stainless steel
threaded insert to attach ballast
housing........................................ S806
• TEFLON® coating on globe for
increased shatter protection.......
S808

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Electrical Rating Ranges:
• 52, 64, and 84 watts
• 120–277V, 50–60 Hz
• 347V, 60 Hz

Accessories:
(Order separately)
Description

Cat. #

Dome
30° Angle

RD739
RA739

9L

Standard Features:

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Energy Savings
• Less wattage used with compact
fluorescent lamps compared to
equivalent incandescent lamps
providing the same light output

About the Battery
(DMVFB Units):
• Bodine fluorescent battery pack ballasts
are UL component recognized
• Sealed, maintenance-free, high
temperature nickel cadmium
• Solid state chargers are sealed inside
the ballast case
• 90 minute illumination time
• 10-year life expectancy
• 2-year full warranty
• During auxiliary use 1 lamp has
continuous operation
• A red indicator light indicates the battery
is charging
• Wiring instructions for a "Push-to-Test"
button is supplied with the fixture

Copyright© 2013 Eaton’s Crouse-Hinds Business

1203

1204-1205.qxp

9L

12/16/2013

7:09 PM

Page 1204

DMVFB Emergency
Compact Fluorescent

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Continuous Operation
Champ® Luminaires

Mounting
Style
Pendant Mount

/4
1
3
/4
1
3
/4
1

52

/4
/4
3
/4

52
64
84

DMVFB2HA052GP
DMVFB2HA064GP
DMVFB2HA084GP

/4
1
3
/4
1
3
/4
1

52

DMVFB2C052GP
DMVFB3C052GP
DMVFB2C064GP
DMVFB3C064GP
DMVFB2C084GP
DMVFB3C084GP

/4
1
3
/4
1
3
/4
1

52

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/ 2° Angle

3

/4
/4
3
/4

52
64
84

DMVFB25Q052GP
DMVFB25Q064GP
DMVFB25Q084GP

Stanchion Mount
25° Angle

11/2
11/2
11/2

52
64
84

DMVFBJ052GP
DMVFBJ064GP
DMVFBJ084GP

Stanchion Mount
Straight

11/ 2
11/ 2
11/ 2

52
64
84

DMVFBP052GP
DMVFBP064GP
DMVFBP084GP

Flexible Pendant
Mount

3

Ceiling Mount
Thru-Feed

3

Wall Mount
Thru-Feed

9L

DMVFB Series
Fluorescent with Battery
Back-Up with G303 Globe
and P33 Guard
Cat. #
DMVFB2A052GP
DMVFB3A052GP
DMVFB2A064GP
DMVFB3A064GP
DMVFB2A084GP
DMVFB3A084GP

Hub
Lamp
Size (In.) Watts
3

3

3

3

64
84

64
84

DMVFB2TW052GP
DMVFB3TW052GP
DMVFB2TW064GP
DMVFB3TW064GP
DMVFB2TW084GP
DMVFB3TW084GP

64
84

Note: For technical information on family
trees, temperature performance data,
dimensions, weights, and photometrics,
refer to Series in Section 5L.

1. Catalog numbers are basic numbers. Voltage must be specified.
Standard Voltage Ballasts
NEC/UL
1. Voltage
Suffix

1204

120–277V 50–60 Hz
/UNV

www.crouse-hinds.com

US: 1-866-764-5454

Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP66
Emergency Lighting

CEC/CSA (cUL)
120V/60 Hz
/120CAN

CAN: 1-800-265-0502

347V 60 Hz
/347

Copyright© 2013 Eaton’s Crouse-Hinds Business

1204-1205.qxp

12/16/2013

7:09 PM

Page 1205

EVLPFB Emergency
Compact Fluorescent
Continuous Operation
Low Profile Luminaires

Cl. I, Div. 1, Groups B
(GB Suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G; Class III,
Simultaneous Presence

Marine & Wet
Locations
3, 3R, 4, 4X; IP66
Emergency Lighting

9L

Applications:
Eaton's Crouse-Hinds Low Profile
Hazard•Gard® Luminaires are used in:
• Areas that require lamps to reach full
lumination immediately
• Where emergency lighting is required to
permit workers in industrial areas to
safely encounter their surroundings
during power failures
• Where emergency lighting is required
such as: catwalks, walkways, tunnels,
doorways, stairs, stairwells, ramps, and
aisles
• Areas where flammable or explosive
vapors or gases are present
• Hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
• Petroleum refineries, chemical,
petrochemical and pharmaceutical
plants, oil terminals, gas plants and
other heavy process industry facilities
• Waste treatment facilities
• Drilling platforms and other coastal and
offshore hazardous areas

Features and Benefits:

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1, Groups B
(with GB suffix), C, D
Class I, Zone 1, Groups IIB + H2
(GB Suffix), IIB, IIA
Class II, Class III & Simultaneous
Presence
(Class I and Class II)
Emergency Lighting
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
924 Emergency Lighting
• CSA Standards:
C22.2 No. 137

Ratings (Electrical/Size):

• Mounting modules, cover, ballast
housing, globe holder – copper-free
aluminum
• Globe – heat- and impact-resistant glass
• Exterior hardware – stainless steel
• Reflectors (dome & angle) – Krydon®
fiberglass-reinforced polyester

Sources/Wattage:
• Fluorescent continuous operation
emergency lighting 52W (2-26W lamps)
and 64W (2-32W lamps) compact
fluorescent voltages
• Fluorescent emergency lighting
120–277V, 50–60 Hz
120V, 60 Hz
347V 60Hz
Conduit entries:
• 3/4", 1" NPT – pendant, wall bracket,
ceiling
• 11/4" NPT – stanchion

Standard Finishes:
• Copper-free aluminum – Corro-free™
powdered epoxy
• Krydon – white
• Stainless steel guard

Energy Savings
• Less wattage used with compact
fluorescent lamps compared to
equivalent incandescent lamps providing
the same light output

Options:
Description
Group B suitability
Fused (not for use in Canada) (not for marine use)
Factory assembled with lamps
Emergency operation only – Consult Eaton's Crouse-Hinds

Suffix
GB
S658*
FA

9L

• Small, compact size
• Two start Acme threaded construction
• Easier assembly, installation, and
maintenance
• Lightweight copper-free aluminum
housing with powdered epoxy finish
• All exterior hardware is corrosionresistant stainless steel
• Four mounting arrangements: pendant,
ceiling, wall bracket, and stanchion
• Integral ballast
• High power factor (90%+) ballasts
• Uses same mounting modules as the
standard Hazard•Gard®
• Internally fluted glass globes
• Krydon® construction dome and angle
reflectors – won't rust, corrode, dent,
chip, or peel
• Now available in components – luminaire
body, mounting module, guard,
reflectors
• Three wire construction
• For energy conservation, luminaires can
be switched off without affecting the
emergency operation feature

Standard Materials:

*When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.

Accessories:
Description

Cat. #

Dome reflector
Angle reflector

RD739
RA739

About the Battery:
• Bodine fluorescent battery pack ballasts are UL component recognized
• Sealed, maintenance-free, high temperature nickel cadmium
• Solid state chargers are sealed inside the ballast case; 90 minute illumination time; 10-year
life expectancy
• 2-year warranty
• During emergency use, 1 lamp has continuous operation
• A red indicator light indicates the battery is charging
• Wiring instructions for a "Push-to-Test" button is supplied with the fixture

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1205

1206-1207.qxp

9L

12/16/2013

7:09 PM

Page 1206

EVLPFB Emergency
Compact Fluorescent
Continuous Operation
Low Profile Luminaires

Cl. I, Div. 1, Groups B (GB Suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G; Class III,
Simultaneous Presence

Marine & Wet
Locations
3, 3R, 4, 4X; IP66
Emergency Lighting

Ordering Information:

Pendant Mount

Pendant
Wall Bracket†
Hub
Size With Guard
With Guard
Watt (In.) Cat. #
Cat. #
Fluorescent with Emergency Ballast – High Power
3
/4
EVLPFBA02521 EVLPFBBX02521
EVLPFBA03521 EVLPFBBX03521
52W 1
11/4
3
/4
1
11/4

64W

EVLPFBA02641
EVLPFBA03641

EVLPFBBX02641
EVLPFBBX03641

Ceiling†

Stanchion

With Guard
With Guard
Cat. #
Cat. #
Factor Ballast (Min. P.F. 90%)
EVLPFBCX02521
EVLPFBCX03521
EVLPFBJ04521
EVLPFBCX02641
EVLPFBCX03641

Luminaire
Body
Less
Mounting
Module &
Guard

Cat. #
EVLPFB0520

EVLPFB0640
EVLPFBJ04641

Complete Catalog Numbers as follows:
Standard Voltage Ballasts
NEC/UL
1.

Voltage

120–277V 50–60 Hz
/UNV

Suffix

2.

Wall Bracket Mount†

CEC/CSA (cUL)
120V/60 Hz
/120CAN

347V 60 Hz
/347

Example: EVLPFB02521/UNV
Other Voltages – Consult Eaton's Crouse-Hinds

Note: For technical information on family trees, temperature performance data, dimensions,
weights, and photometrics, refer to DMVF Series in Section 5L.

EVFPFB Fluorescent Emergency Lighting

9L

• Three wire construction, for switching purposes, is standard on fluorescent emergency lighting.
• For energy conservation, luminaires can be switched off without affecting the emergency operation
feature.

Ceiling Mount†

*Test switch is remote mounted.
Use Eaton's Crouse-Hinds EDSC218 (not furnished).

Stanchion Mount
†Ceiling and bracket mounts have 4 hubs: 3 are plugged.

1206

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1206-1207.qxp

12/16/2013

7:09 PM

Page 1207

Ex-Lite LED Exit Signs

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 1, AEx em ib IIC (NEC)
Cl. I, Zone 1, Ex em ib IIC (CEC)
Cl. II, Div. 2, Groups F, G (NEC)
Cl. II, Div. 2, Groups E, F, G (CEC)

9L

UL Listed
IP66

The Ex-Lite Series of LED exit signs are
designed for hazardous locations and are
ideally suited for marking escape routes
and exits in potentially explosive
atmospheres.
The Ex-Lite Z is available as an AC only
version, while the Ex-Lite ZE is available
with self-contained battery. As an
emergency lighting luminaire with selfcontained battery system, the Ex-Lite ZE
features a nickel cadmium battery with
automatic test and monitoring feature.

Applications:
• In harsh and hazardous environments
where illuminated exit signs are required

Features and Benefits:
Ordering Information:
Catalog Number
Material Number
Description

Ex Lite Z
12191001005
AC/DC Exit Sign

Ex Lite ZE
12191130005
with Battery

Light Source
Life of LED
Rated Voltage, VAC
Frequency, Hz
Rated Voltage, DC
Power Consumption
Battery

LED
50K hours
120V-277V
50/60
110V-250V
6VA
N/A
-4ºF to 122ºF
(-20ºC to 50ºC)
Wall
Ex-e
3
/4"
IP66

LED
50K hours
120V-277V
50/60
110V-250V
6VA
NiCad
41ºF to 95ºF
(5ºC to 35ºC)*
Wall
Ex-e
3
/4"
IP66

Allowable Temperature Range
Mounting
Cable Entry
Conduit Entry
Protection

9L

LED Technology:
• Long life (>50K hours) for years of
maintenance-free operation
• Energy-efficient for lower cost of
operation
• Low temperature operation with no loss
of illumination
• Rugged and durable light source for the
harshest of environments
Exit Sign System:
• Can be used in a hazardous location
• Conduit or cable entry
• Can be installed in moist, humid, rain,
and wet environments
• Universal input voltage 110VAC-277VAC
and 110VDC-250VDC reduces inventory
• Ex-Lite ZE with self-monitoring, selfdiagnostic, and test capability
• Premium heavy-duty nickel cadmium
battery
• 24-hour charge and recharge time
increases safety by recovering quickly
from outage
• "EXIT" legend with alternative wings left, right, or left and right; simple field
modification
• Emergency lighting cycle three hours
• The housing of the luminaire is
constructed with a corrosion resistant,
robust, lightweight aluminum alloy
material and illumination of the sign is
provided with red, high-efficient LEDs

*Due to battery chemistry, the charging capacity will be limited at temperatures below 5ºC and above 35ºC.

Dimensions
In (mm):

Certifications and
Compliances:
•
•
•
•
•
•
•
•
•
•

Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, AEx em ib IIC (NEC)
Class I, Zone 1, Ex em ib IIC (CEC)
Class II, Division 2, Groups F, G (NEC)
Class II, Division 2, Groups E, F, G
(CEC)
IP66
UL844
UL924/CSA22.2 No. 141-02
UL60079/CSA22.2 E60079
UL1203/CSA22.2 E6124-1-1-02
www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1207

1208-1209.qxp

12/16/2013

9L

7:11 PM

Page 1208

NEMA 4X, IP66

UL Listed
Available with Cl. I, Div. 2,
Groups A, B, C, D rating

CCH UX Series
LED Exit Signs

Eaton's Crouse-Hinds CCH UX Series LED Exit Sign combines the
strength and durability of die cast aluminum with architecturallypleasing aesthetics. The CCH UX Series is illuminated by LEDs,
providing the customer with a long-life, low maintenance,
dependable exit sign for use in conditions where reliability is crucial.
Designed for the most severe environments, the CCH UX Series will
provide maximum performance against rain, moisture, cold,
corrosion, and dust in applications such as manufacturing plants,
refineries, petrochemical and chemical plants, waste and sewage
treatment facilities, food processing, and other industrial facilities.

Applications:
• In locations deemed hazardous due to the presence of flammable
vapors or gases
• In areas where the presence of gases or vapors may become
present during an abnormal, unusual, or accidental conditions
• Outdoor and wet applications
• Where required by the National Electrical Code®, Life Safety
Code®, or other applicable codes

9L

Features and Benefits:
• Wet location, outdoor rated for use in the most demanding
environments
• Optional hazardous location rating available
• Dual voltage 120V/277V reduces wiring errors
• Heavy-duty nickel cadmium battery for long life
• 24-hour charge and recharge recovery time increases safety
• Heavy-duty injection molded polycarbonate lens protects against
impact and corrosion
• Brown-out protection protects battery and reduces labor
• Heavy-duty aluminum die cast housing protects against impact
and chemical resistance
• LEDs provide long life, even illumination, and energy savings
• Wide operating temperature range (-45°C to 45°C)
• Self-diagnostic testing reduces costs by eliminating scheduled
equipment verification tests
• Heavy duty nickel cadmium battery for long life meets 90 minute
requirements for battery operated emergency system

Certifications and Compliances:
•
•
•
•

NEMA 4X, UL50
UL924 wet location
IP65, IP66
Available with NEC hazardous location rating
- UL844 Class I, Division 2, Groups A, B, C, D

In Inches:

Mounting: wall mount, ceiling mount, end mount
Conduit Entry: top, bottom, or either side of the unit
www.crouse-hinds.com

US: 1-866-764-5454

• Provides safe and reliable exit marking both indoors and outdoors
during power failure or interruption of power to normal lighting
system
• Long life (>50K hours) for years of maintenance-free operation
• Energy-efficient for lower cost of operation
• Low temperature operation with no loss of illumination
• Rugged and durable light source for the harshest of environments

Temperature Performance Data:
CCH UX Series Exit Sign:
• -45ºC (-49ºF) to 45ºC (113ºF)
CCH UX-HAZ Hazardous Location Exit Sign:
• T6 rating at 45ºC (113ºF)

Electrical Ratings:
• Power Supply
120V/277V dual voltage
• LED Exits - Red
Input Power
120V = 2.7W
277V = 3.2W

• LED Exits - Green
Input Power
120V = 2.3W
277V = 3.0W
Input Current:
(Max.)
120V = .08A
277V = .03A

Input Current:
(Max.)
120V = .07A
277V = .04A

Ordering Information:

Dimensions

1208

Benefits of LED Technology:

CAN: 1-800-265-0502

Catalog Number

Housing Finish

Letter Color

CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH
CCH

Silver Housing
Silver Housing
Silver Housing
Silver Housing
Silver Housing
White Housing
Black Housing
Silver Housing
White Housing
Black Housing
Silver Housing
White Housing
Black Housing
Silver Housing
White Housing
Black Housing

Red LED
Red LED
Green LED
Green LED
Red LED
Red LED
Red LED
Red LED
Red LED
Red LED
Green LED
Green LED
Green LED
Green LED
Green LED
Green LED

UX70RSDHAZ
UX60RHAZ
UX70GSDHAZ
UX60GHAZ
UX70RSD
UX70RWHSD
UX70RBKSD
UX60R
UX60RWH
UX60RBK
UX70GSD
UX70GWHSD
UX70GBKSD
UX60G
UX60GWH
UX60GBK

Copyright© 2013 Eaton’s Crouse-Hinds Business

1208-1209.qxp

12/16/2013

7:11 PM

Page 1209

Specialty Lighting

10L

Tank, Task and Gauge Lighting
Hazardous and Non-hazardous Locations
Description

Page No.

Application/Selection

see page 1210

Gauge Light

see page 1216

Tank Light
V160
EVA160

see page 1211
see page 1212

Task Light
EVTL1B50
EVTL1L50

see pages 1213–1215
see pages 1213–1215

10L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1209

1210-1211.qxp

10L

12/16/2013

7:11 PM

Page 1210

Specialty Lighting
Tank, Task and Gauge
Hazardous and Non-hazardous Locations
Application and Selection

Applications:

Considerations for
Selection:
Environmental:
• What is the hazardous area
classification (NEC)/(CEC) of the
location in which the luminaire will be
installed?
Lighting levels required:
• What wattage luminaire(s) will provide
the desired light level?
Physical Arrangement:
• Type of fixture mounting needed

Product Selection:
• EV Tank Lights are suitable for use in
Class I, Groups C, D hazardous
(classified) locations; tank lights are
used to light the inside of tanks, vats,
process vessels, etc.
• EVTL Explosionproof Task Lights are
suitable for use in Class I, Group B, C, D
and Class II, Groups E, F, G hazardous
(classified) locations; EVTL Lights are
ideal for applications in which water
spray and corrosive atmospheres are
considerations
• ELG Gauge Lights are suitable for use in
Class I, Groups C, D hazardous
(classified) location; the light is used to
illuminate liquid level gauges and to
direct the light over the length of the
column

10L

Specialty lighting luminaires are used:
• For various task lighting requirements in
locations that are hazardous (classified)
due to the presence of combustible
dusts or easily ignitible fibers and flyings
• In areas where conventional lighting is
not acceptable due to size and/or
location
• In locations where an adequate light
source is necessary for tank, instrument,
and gauge applications
• In manufacturing plants, refineries,
pharmaceutical, chemical,
petrochemical, and other industrial
process facilities, waste or sewage
treatment facilities, grain processing and
handling facilities, and other heavy
industrial applications

1210

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1210-1211.qxp

12/16/2013

7:11 PM

Page 1211

V Observation Incandescent
Luminaire

10L

Watertight

Applications:
The incandescent V Observation Luminaire
is used:
• In tanks or kettles where food is
processed
• To light the inside of tanks for
observation of the contents through a
window

Features:
• Watertight
• Supported by a mounting ring which
contains holes for riveting when placed
around a hole in the tank; it can also be
welded or brazed to the tank
• Heavy heat and impact-resistant glass
globe eliminates breakage and resultant
contamination of food from glass
particles
• Relamping is easily accomplished by
removal of the two thumb-screws which
fasten the body to the mounting ring
• The flexible cord or cable should be
connected by an EC flexible coupling or
CG Series connector

Certifications and
Compliances:

Furnished with EV10 Globle, and
C166 Medium Base Lamp Receptacle
Hub Lamp Size

Size

Cat. #

11/2"

50, 60,
75 or
100W,
A-21

V160

Dimensions
In Inches:

• UL Standard: 1571
• CSA Standard: C22.2

Standard Materials:
• Mounting ring – silicon bronze
• Fixture body – Feraloy® iron alloy
• Globe – heat-resisting glass

10L

Standard Finishes:
• Feraloy – electrogalvanized and
aluminum acrylic paint
• Bronze – natural

Size Ranges:
• Up to 100 watt, A-21 lamp

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1211

1212-1213.qxp

12/16/2013

10L

7:11 PM

Page 1212

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Zone I & 2, IIB
Cl. II, Div. 1, Groups E, F, G – EVO only

EV Tank Luminaires

Applications:

Temperature Performance Data:

EV Tank Light Luminaires are used:
• To light inside of tanks, vats, process
vessels, etc.
• In chemical plants, petrochemical plants
and petroleum process industries
• Suspended over tank porthole by EC
flexible hanger (EVO style)
• Mounted directly in tank wall (EVA)

Based on 40°C Ambient
Cat. #

Class I,
Groups C, D

Class II,
Groups E, F, G

Supply
Wire (°C)

EVO2376
EVA160

T3C
T3C*

T3C
—

75
75

*All mounting positions.

Dimensions
In Inches:

Features:
• High light output
• Compact design
EVA160:
• Furnished with tank ring having eight 3/16"
holes for riveting to tank
• Can be brazed if desired
• Luminaire ring is attached to the tank
ring by eight 1/4-20 Allen Head cap
screws
• Luminaire attached to luminaire ring by
four wing screws
• EC flexible luminaire support should be
used so relamping can be accomplished
without disturbing the globe

EVO2376
EVO2376

Certifications and
Compliances:
• NEC:
Class I, Division 1 and 2,
Groups C, D – EVO and EVA
Class II, Division 1,
Groups E, F, G – EVO only
• UL Standard: 844
EVA160

10L

Standard Materials:
• Bodies – EVO: copper-free aluminum;
EVA: receptacle housing and
intermediate ring – Feraloy® iron alloy;
Tank ring – silicon bronze
• Globes – EVO – glass, heat
strengthened plate glass; EVA: glass,
heat- and impact-resistant

Standard Finishes:

EVA160

Ordering Information:
Cat. #

Watts

Lamp (not furnished)

Hub Size

EVO2376
EVA160

75
100, A-21

75R 30/SP reflector spot (medium base)
Medium base

1

Tank Ring Mounting
EVA160

• Copper-free aluminum – epoxy powder
coat
• Feraloy iron alloy – cadmium
electrogalvanized and aluminum acrylic
paint
• Silicon bronze – natural

Size Ranges:
• 1/2" and 3/4" hubs

Capacity Ranges:
• EVO – 75 watt, reflector spot max.
• EVA – 100 watt, A-21 max.

1212

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

/2 & 3/4
/2

1

1212-1213.qxp

12/16/2013

7:11 PM

Page 1213

Cl. I, Groups B, C, D
Cl. I, Zone I, IIB+H2
Cl. II, Groups E, F, G
Class III Simultaneous
Presence

EVTL Explosionproof Task Light

Wet Locations
Marine Locations
NEMA 3, 3R, 4, 4X

10L

Applications:
EVTL Task Light Luminaires are used:
• For various task lighting requirements in
locations that are hazardous (classified)
due to the presence of flammable gases
or vapors, combustible dusts, or easily
ignitible fibers and flyings
• In marine applications where water spray
and corrosive atmospheres are
considerations
• In areas where conventional lighting is
not acceptable due to size and/or
location
• In locations where an adequate light
source is necessary for tank, instrument,
and gauge applications
• In porthole or sightglass applications
where a spotlight is required for visibility
inside tanks, vats, and process vessels
• In manufacturing plants, refineries,
pharmaceutical, chemical,
petrochemical, and other industrial
process facilities, waste or sewage
treatment facilities, grain processing and
handling facilities, and other heavy
industrial applications

Features and Benefits:

EVTL1L50

Certifications and
Compliances:

Standard Materials:

• NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class II, Group E, F, G
Class III
Class I, Zone 1 & 2, Group IIB + H2
Wet locations
Marine locations
NEMA 4X
• NEC:
Simultaneous Presence
• UL Standards:
844—Hazardous (Divisions Classified)
Locations
1571—Ordinary and Wet Locations,
Marine Outside Type
• CSA Standards:
C22.2 No. 137

• Housing — copper-free aluminum
• 3/4" NPT hub and plug — aluminum
• Mounting bracket(s) and external
hardware — stainless steel
• Gasket — silicone rubber
• Lens — heat- and impact-resistant
clear glass

Standard Finishes:
• Aluminum housing (exterior) —
Corro-free™ epoxy powder coat
• Stainless steel — natural

Ratings (Electrical/Size):
Source/Wattage (Medium Base
Lamps)
• 50PAR20 type—50W 120V halogen
parabolic reflector; lamp life 2000-2500
hrs.
• 130V lamps available to extend lamp
life to 5000+ hrs.

Voltage
• 120V 60 Hz

Hub Size
• (1) 1/ 2" NPT
• For through-feed, use EVTL-TF1

Ordering Information:
Cat. #

Conduit Entry

Mounting Style

Wattage

EVTL1B50
EVTL1L50

1

/2"
1
/2"

Bracket (Universal)
Leg (Site Glass)

50
50

Temperature Performance Data:

Cat. #

Maximum
Ambient °C

Class I, Div. 1, Groups B, C, D
Class II, Div. 1, Groups E, F, G
Class III
Simultanenous Presence
Class I, Zone 1, IIB + H

EVTL1B50
EVTL1L50

40
40

T3B
T3B

Supply
Wire °C
85
85

Install luminaire within aiming ranges shown on nameplate (see Dimensions).

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1213

10L

• Class I, II, III, Simultaneous Presence suitable for most hazardous (classified)
areas
• Class I, Group B standard - suitable for
areas containing hydrogen
• Wet and marine (NEMA 4X) suitability perfect for hose down applications
• 55° ambient suitability addresses higher
ambients typical of industrial plants
• Cast copper-free aluminum housing with
Corro-free™ epoxy powder coat finish for
superior corrosion resistance
• Stainless steel mounting brackets and
hardware for superior corrosion
resistance
• Two mounting styles (bracket and leg) to
maximize mounting flexibility
• Bracket (universal) for ceiling, wall, or
base mounting
• Leg (site glass) for site glass mounting
• Uses standard 50 watt PAR 20 medium
base 120V lamps - improved light
output, economical, long life 2000-2500
hour light source
• Uses 50PAR20 130V lamps for added
lamp life - increase lamp life to 5000+
hours while maintaining 76% lumen
output
• 50PAR20 lamps available in both flood
and spot light patterns - vary the
illumination characteristics by simply
changing lamps
• Easy access interior reduces
maintenance and lamp replacement time
• Seal within 5 ft. (not 18") of luminaire
provides greater flexibility in seal
location

EVTL1B50

1214-1215.qxp

12/16/2013

10L

7:12 PM

Page 1214

EVTL Explosionproof Task Light

Dimensions and Weights

Aiming Range:

Dimensions:

10L

Bracket Mount

Dimensions:
Leg Mount

Net Luminaire Weights:
(lbs.)
Luminaire Cat. #

Weight (lbs.)

EVTL1B50
EVTL1L50
EVTL-TF1

7
7
1
/2

1214

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1214-1215.qxp

12/16/2013

7:12 PM

Page 1215

EVTL Explosionproof Task Light

Photometric Data

10L

Lamp Light Distribution – (Philips lamp data shown. Similar for other manufacturers.)
Data shown is for 120 volt lamps.
For 130 volt lamps adjust data using a .76 multiplier.

10L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1215

1216.qxp

12/16/2013

7:12 PM

Page 1216

10L

ELG Gauge Luminaires

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Zone 1 & 2, IIB
Explosionproof

Applications:
ELG Gauge Lights are used:
• In hazardous areas to illuminate liquid
level gauges over entire length of gauge
• Clamped to rear of liquid level gauge
and conduit is attached to the ELG
hubs; light is reflected by Lucite reflector
along the entire length of the gauge;
liquid level shows on front of gauge; all
light is concentrated on liquid column –
no spill light

Features:
• Even illumination over entire length of
gauge
• Variety of sizes to fit many gauges
• Several lights can be used in tandem to
illuminate long gauge

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 and 2, Groups C, D

ELG329 with LE49 reflector

Standard Materials:
• Body – copper-free aluminum
• Reflectors – plexiglass

Ordering Information:

Standard Finishes:

Description

• Body – electrogalvanized and aluminum
acrylic paint

Gauge Light
(less reflector)

—

ELG329

Size Ranges:

Short
– Style Reflector

41/2
51/2

LE34
LE35

Long
– Style Reflector

13
15
17
193/4
22
251/4
263/4

LE46
LE47
LE48
LE49
LE410
LE412
LE413

• 1" conduit through-feed

10L

Capacity Ranges:
• 120V medium screw base "A19" style
incandescent lamp 58W maximum
• 25 watt – medium base – 1000 hour life
• 52 watt – medium base – 2500 hour life
• 58 watt – medium base – 3000 hour life

Length (L)
(inches)
Cat. #

Dimensions:
Plexiglass Reflectors
Short Style

Long Style

Temperature Performance
Data:
Based on 40°C ambient
58 Watt – T4A Maximum

Options:
Description
Suffix
Group B suitability ...........................
GB

Suggested Lamps:
Lamps not furnished
Manufacturer

Cat. #
25
52
Watt Watt

General Electric
Osram/Sylvania
Philips

25A
25A
25A

1216

60A/52WMP/98
60A/52/SS/XL
60A-52A/99/EW

www.crouse-hinds.com

US: 1-866-764-5454

58
Watt
58A19/62

Volts
120
120
120

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Modify Date                     : 2014:02:12 13:35:27-05:00
Create Date                     : 2014:02:10 15:38:46-05:00
Metadata Date                   : 2014:02:12 13:35:27-05:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Creator                         : mabe
Document ID                     : uuid:9b2c706b-72da-4574-9a32-65adc77a63ee
Instance ID                     : uuid:3e995305-2d3d-416f-9aa6-76a90cb488f7
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Page Count                      : 356
Author                          : mabe
GTS PDFX Conformance            : PDF/X-1a:2001
GTS PDFX Version                : PDF/X-1:2001
Title                           : 
Trapped                         : False
EXIF Metadata provided by EXIF.tools

Navigation menu