16294 P2 Panelboards 110355 Catalog
2014-07-05
: Pdf 110355-Catalog 110355-Catalog 783310 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 14
Download | |
Open PDF In Browser | View PDF |
S I E M E N S I N C A N A D A Siemens is one of the largest and most diversified companies in the world, providing innovations in areas such as health care, information & communications, energy & power, industry & automation, transportation and lighting. In Canada, Siemens is headquartered in Mississauga, Ontario, and has 73 offices and nine manufacturing facilities across the country. Locations span from coast to coast, staffed by more than 6,200 employees. I N D U S T RY A N D AU T O M AT I O N I N H E A L T H C A R E , we provide complete integrated solutions, from diagnostic imaging equipment, telemedicine solutions, clinical networking systems and patient monitoring/life support systems to consultative services and staff training. These offerings not only improve patient care but also increase administrative, financial and clinical efficiencies and streamline workflow processes. As the world’s largest manufacturer of hearing instruments, Siemens offers assistive listening devices that improve quality of life for the hard of hearing. P2 PANELBOARDS SELECTION & APPLICATION GUIDE I N I N F O R M A T I O N & C O M M U N I C A T I O N S , we continue to focus on an ever-widening range of network technologies including the engineering and integration of next generation voice, data, standard and wireless applications. In the Canadian cellular market, Siemens is breaking new ground in establishing GSM services with a strong GSM/GPRS portfolio. We offer complete solutions for network access, optical switching and core routing technologies and we are a leading provider of single-source IT consulting solutions and management services for supply chain, enterprise resource, business information and customer relationship. I N E N E R G Y & P O W E R , we supply reliable power solutions, from generation and distribution to control and automation applications. We provide the most responsive sources of solutions to improve the competitiveness and profitability of our customers’ operating plants. 1.0_04/04_A&D-1305 I N I N D U S T R Y & A U T O M A T I O N , we offer integrated automation solutions to increase productivity at all levels of industry, from component-level support and simple process control to designing, building, commissioning, servicing and maintaining integrated plant systems. To help our customers manage their facilities more efficiently, we provide building maintenance services and control systems from fire alarms to climate control. We also offer a full range of postal automation systems and support services. I N T R A N S P O R T A T I O N , Siemens offers a wide range of rail vehicles, from complete transportation systems and people movers to rolling stock for light rail, heavy rail and subways. In addition, we supply all major transportation system elements, such as train control, systems electrification and systems maintenance. For the automotive industry, we have developed a new technology involving electronically controlling engine acoustics via the air intake system. Your local contact is: I N L I G H T I N G , through OSRAM SYLVANIA LTD., we are a leader in the Canadian lighting market, dedicated to setting new market standards in commercial & industrial, consumer, automotive, specialty and lighting services. I N F I N A N C I N G , we provide a full range of customized financial services for the acquisition of capital equipment and services. We offer complete financial solutions including: loans; leases; project funding; financial expertise; technology leases and customized applications. Siemens Canada Limited Automation & Drives 1550 Appleby Line, Burlington, ON L7L 6X7 Customer Interaction Centre Tel: (888) 303-3353 For further innovations visit www.siemens.ca 2004 P2 Panelboards Description General Information Selection and Application Application Panel Unit Space To Box Height Requirements Main Lug Connectors Branch Breaker Side Gutters Main Breaker Selection Subfeed Breakers Branch Circuit Breakers Branch Neutral Connections Page 2 2 3-5 3 3 3 4 4 5 5 Description Typical Catalogue Numbers Main Lugs Only Main Circuit Breakers Standard Modifications Box Size Additions For Optional Features Connector Modifications Compression Lugs Enclosure Modifications Remote Switch Modifications Dimensions Kits and Accessories Page 6 6 6 7 8 9-10 9 10 10 11 12 P2 Panelboards P2 Panelboards Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet almost all lighting panel applications. With this design, the ability to mix breaker frames in unit space up to 250 amps will also meet many distribution panel requirements in a much smaller package. Busing options for the P2 vary from the typical temperature rated to 750 A/Si aluminum to 1000A/Si copper. Standard busing in the P2 panel is tin-plated. Silver-plated copper is also offered as an option. Integrated time clocks, bus mounted contactors, as mains or sub mains, split bus, and subfeed lugs (up to 400 amp) are just a few of the options of this unique panel. Like a lighting panel, P2 is set up around 18, 30, 42, and 54 circuit configurations. It will also allow the user to configure the panel to the smallest possible size. The P2 panel starts with 9” of unit space (18 circuits of 1” pole breakers). Breakers mounted in unit space can be mixed and matched to meet customer requirements. All 1” pole breakers (BL, BQD, ED frames) are mounted in 3” or 6” pole increments. Breaker frames, above 125 amps, are mounted in 6” single breaker mountings. As an example of a minimum panel, (6) 20 amp 1-pole BL breakers (3” of unit space) and a 3-pole 225 amp QJ breaker (6” of unit space) equaling 9” of unit space can be configured in a P2 panel without any extra provisions or space required. FD 250 amp and JD 400 amp breakers are mounted as subfeed breakers outside of unit space. Another unique feature of the P2 panel is that blank unit space can be added to allow for future expansions or modifications. Any expansions or modifications must be in 3” increments. BL, BQD, and ED frame breakers have 3” or 6” pole kits, and can be mixed in unit space by these increments. Breakers of the same frame can cross from one mounting to another if contiguous. QJ frame breakers are mounted in 6” increments for two and three pole, single mounted units. Changes in the unit space length for BL, BQD, or ED frame breakers require an addition deadfront, center strip kit. Check with sales or the factory for additional unit space kits. Main Lug / Main Breaker Enclosure – Standard Type 1 enclosure is 20" wide x 5.75" deep X. Box Height is determined by main device and unit space. See charts for box height. Voltage – 600 Vac Max. 250 Vdc Max. Amperage – 600 amp Max. Short circuit rating – 200 KAIC Max. symmetrical or equal to the lowest rated device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to a three-cycle rating. The three-cycle rating for the P2 panel is limited to 22 KAIC. Note that the main device may be mounted remote from the panel. Busing – The P2 panel has more options to meet market requirements. The standard busing is temperature rated aluminum. The rating is per the requirements of CSA: 22.2 No. 29 – the standard for panelboards. All aluminum busing is tin-plated. Optional busing for the P2 panel is: 750 A/Si aluminum, temperature rated copper, and 1000 A/Si copper. The copper bus option for this panel is tin-plated. Weight – Approximate Total panelboard weight when filled with a normal quantity of breakers and accessories is about 3 lbs. (1 kg) per inch (54g per mm) of box height. Table P2-1 – Gauge Steel of Boxes Fronts, Surface and Flush Dimensions in inches (mm) Width Height 20” 26 - 74 (508) (660, 1880) Gauge Steel Box #16 Front #14 Selection and Application Step 1 Step 2 Step 3 Determine configuration required. Create a catalogue number by following the Catalogue Numbering System on page 6. Note that the number of circuits number (4th and 5th position) will be 18 for those panels with 6-18 circuits, 30 for those panels with 19-30 circuits, 42 for those panels 31 to 42 circuits and 54 for those panels 43 to 54 circuits. The most cost effective 20 amp 1-pole breaker for this application would be BL. However, a myriad of other breakers with options may be used in the P2 panel. The most cost effective 225 amp breaker for this application is the QJ2. Determine the enclosure size. The matrix on page 2-3 shows the enclosure sizes based on the amperage, main device and unit space required. Example: Amperage Voltage System Main Bus Material Interrupt Rating Branch Devices Feed Location Mounting 250A 208Y/120V 3Ø4W Main Lug Temperature rated aluminum 10 Ka (6) 20 amp,1-pole (1) 225 amp, 3-pole Top Surface Based on the above P2C18ML250ATS (6) BL 20 amp 1-Pole (1) QJ2 225 amp 3-pole 2 Siemens P2 Panelboards – Selection & Application Guide Application P2 Panelboards Table P2-2 – Panel Unit Space To Box Height Requirements P2 Panels With Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension “B” Main Breakers Dimen- Main Lugs sion 125A 250A 400A 600A 125A 125A 125A 225A 250A 250A 400A 400A Box Horiz. Horiz. Vert. Horiz. Horiz. Vert. JD CJD Height BL,BQD,ED CED ED QJ FD CFD 26 32 38 44 50 56 62 68* 74* 9 15 21 27 33 39 45 51* 57* — 9 15 21 27 33 39 45 51* — — 9 15 21 27 33 39 45 — — 9 15 21 27 33 39 45 9 15 21 27 33 39 45 51* 57* — 9 15 21 27 33 39 45 51* 125 225 250 400 600 Breaker Frames BL BQD ED QJ FD JD LD Fig. P2-1 — 9 15 21 27 33 39 45 51* — — 9 15 21 27 33 39 45 — — — — 9 15 21 27 33 — — — — 9 15 21 27 33 — — — — — — 9 15 21 600A CLD — — — — — 9 15 21 27 — -— — — — — 9 15 21 Table P2-4 – Main Lug Connectors (Fig. P2-2) Table P2-3 – Main Breaker (Fig. P2-1) Panel Amps 100 — 9 15 21 27 33 39 45 51* 600A LD C 5.75 5.125 4.00 5.00 5.00 14.00 15.50 D 8.00 8.00 8.00 7.00 7.00 25.00 23.00 Panel Amps 125 250 400 600 Standard Connectors (1) #14 - 2/0 (1) #6 AWG - 350 Kcmil (1) #4 AWG - 600 Kcmil or (2) #6 - 250 Kcmil (2) #4 AWG - 500 Kcmil C 6.62 12.34 14.00 D 8.19 11.22 13.09 14.00 11.00 Table P2-5 – Branch Breaker Side Gutters Inches (mm) (Fig. P2-3) Fig. P2-2 Reference Letter A B C D1 Panel Width 20” (508) 5.750 (146) 5.125 (130) 4.000 (102) 5.000 (127) 1 Single branch mounting construction. Fig. P2-3 A B C D Box depth = 5.75 in. (146 mm) Box width – 20 in. (508 mm) for 100-600A Box depth = 5.75 in. (146 mm) Box width – 20 in. (508 mm) for 100-600A BL, BLH, HBL BL, BLH, HBL BLF, BLFH BLF, BLFH BQD, BQD6 BQD, BQD6 ED, ED4, ED6 ED, ED4, ED6 HED4 HED4 QJ2,QJH2,QJ2-H, HQJ2H (Single Mounted) A B C D Panel Width 20 in. (508 mm) *Contact local Siemens representative before ordering. Siemens P2 Panelboards – Selection & Application Guide 3 Application P2 Panelboards Table P2-6 – Main Breaker Selection 1 Ampere Rating 100 125 225 250 400 600 Breaker Type BL (STD) HBL BQD (STD 480/277 Vac) ED4 ED6 HED4 CED6 ED4 (STD) ED6 HED4 CED6 QJ2 (STD) QJH2 QJ2H FD6, FXD6 HFD6, HFXD6 CFD6 FD6, FXD6 (STD) HFD6, HFXD6 CFD6 JXD6 (STD), JD6 HJD6, HJXD6 SJD6 CJD6,SCJD6 LXD6 (STD) LD6 HLD6, HLXD6 SLD6, SHLD6 CLD6, SCLD6 Maximum Interrupting Rating (kA) 240V 480V 10 — 65 14 65 18 65 25 100 42 100 65 200 200 65 18 65 25 100 42 200 200 10 — 22 — 42 — 65 35 100 65 200 150 65 35 100 65 200 150 65 35 100 65 65 35 200 200 65 35 65 35 100 65 65 35 100 65 200 150 600V — — — — 18 — 100 — 18 — 100 — — — 18 25 100 18 25 100 25 35 25 100 25 25 35 25 35 100 Available Trip Values 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100 125 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 70, 80, 90, 100, 110, 125, 150, 175, 200, 225 250 200, 225, 250, 300, 350, 400 200, 225, 250, 300, 350, 400 200, 300, 400 200, 300, 400 450, 500, 600 250, 300, 350, 400, 450, 500, 600 250, 300, 350, 400, 450, 500, 600 300, 400, 500, 600 300, 400, 500, 600 300, 400, 500, 600 1 Interchangeable trip main breakers are mounted at top of panel only. Table P2-7 – Subfeed Breakers Breaker Type Mounting Position When Used As Subfeed Breaker Vertical Maximum Interrupting Rating (kA) Symmetrical Ampere Ratings For Load 240V AC 480V AC 600V DC FD6 1 , FXD6 HFD6 1 , HFXD6 JD6 2 , JXD6 HJD6 2 , HJXD6 Twin Twin Single Single 70 - 250 70 - 250 200 - 400 200 - 400 65 100 65 100 35 65 35 65 18 25 25 35 1 Twin mounted subfeed breakers are mounted at bottom of panelboard only and adds 24" to the panel height. 2 Subfeed breaker is mounted at bottom of panelboard only. 400 amp subfeed breaker adds 30" to the panel height. 4 Siemens P2 Panelboards – Selection & Application Guide Application P2 Panelboards Table P2-8 – Branch Circuit Breakers Max. Amp Rating Bolt-On Breaker Type BL BL, HID BLR BLE BLEH BLF 100 BLHF BGL 1 BAF BAFH BLH HBL BQD ED2 ED4 125 ED6 *CED6 225 QJ2 QJH2 QJ2-H HQJ2H No. of Poles 1 2 3 1 2 2 1 2 1 2 1 2 1 3 2 3 1 1 1 2 3 1 2 3 1 2 3 1 2/3 1 2 3 2 3 1 2 3 2/3 2/3 2/3 2/3 Amp Rating 15 - 70 15 - 100 15 - 100 15 - 30 15 - 30 15 - 100 15 - 30 15 - 60 15 - 30 15 - 60 15 - 30 15 - 60 15 - 30 15 - 60 15 - 30 15 - 30 15, 20 15, 20 15 - 70 15 - 100 15 - 100 15 - 70 15 - 100 15 - 100 15 - 100 15 - 100 15 - 125 15 - 125 15 - 125 60 - 225 60 - 225 60 - 225 100 - 225 Maximum Interrupting Rating (kA) Volts – AC 120 120/240 240 10 — — — 10 — — — 10 10 — — — 10 — — — 10 10 — — — 10 — 22 — — — 22 10 — — — 10 — 22 — — — 22 — 10 — — — 10 — 10 — — 22 — — — 22 — — 22 — — — 22 — 65 — — 65 — — — 65 — 65 — — 65 — — — 65 10 — — — 10 — 65 — — — — 65 — — 65 — — 65 — — 65 — — — — 200 200 — 200 200 — — 10 — — 22 — — 42 — — 100 1 Two pole breaker is one phase and neutral. Three pole is two phase and neutral. NOTE: QJ Breakers are single mounted in unit space and take 6” of unit space. Limited to (3) per panel max. BL, HBL, BLH and BQD breakers are mounted in 480 — — — — — — — — — 600 — — — — — — — — — DC 250 — — — — — — — — — — — — — — — — — — — — — — — 14 — — — — 22 — — — — — 200 200 — — — — — — — — — — — — — — — — — — — 14 14 — — — 18 18 25 25 — 200 200 — — — — — — — — — — — — — — — — — — — — — — — — — — 18 18 — 100 100 — — — — — — — — — — — — — — — — — — 14 14 14 — 5 (2-P) — 30 — 30 — — — 50 — — — — common mountings in 3” or (6) pole increments. ED2, ED4, ED6 and HED4 breakers are mounted in common mountings in 3” or (6) pole increments. Table P2-9 – Branch Neutral Connections Branch Device Limitations For panels applied on systems requiring neutral connections, some limitations apply. By application rule (NEC 480.14) lighting and appliance panels are limited to 42 circuits installed. Each overcurrent device pole counts as a circuit. Additional limitations for these panels are based on available neutral connections. *Contact local Siemens representative before ordering. 277 — — — — — — — — — Wire Range #14-#6 #14-1/0 #6 - 350 Kcmil (1) #4-600 Kcmil or (2) #6-250 Kcmil 1 Max. Number of Connections 26 28 3 1 Max. Amps 1 65 125 250 400 Based on 75 degree copper. Siemens P2 Panelboards – Selection & Application Guide 5 Typical Catalogue Numbers P2 Panelboards Table P2-10 – Main Lugs Only (1)(2)(4)(5) Maximum Panel Amp Rating Maximum 1-Pole Circuits (6) 18 30 42 54 66 78 90 18 30 42 54 66 78 90 18 30 42 54 66 78 90 18 30 42 54 66 78 90 125 250 400 600 Box Height inches (mm) 26 32 38 44 50 56 62 32 38 44 50 56 62 68 38 44 50 56 62 68 74 38 44 50 56 62 68 74 Catalogue Number (2) 3Ø4W 208Y/120V 1Ø3W 120/240V 3Ø4W 480Y/27V 3Ø4W 347/600V P2C18ML125ATS P2C30ML125ATS P2C42ML125ATS P2C54ML125ATS P2C66ML125ATS P2C78ML125ATS P2C90ML125ATS P2C18ML250ATS P2C30ML250ATS P2C42ML250ATS P2C54ML250ATS P2C66ML250ATS P2C78ML250ATS P2C90ML250ATS P2C18ML400ATS P2C32ML400ATS P2C42ML400ATS P2C54ML400ATS P2C66ML400ATS P2C78ML400ATS P2C90ML400ATS P2C18ML600ATS P2C30ML600ATS P2C42ML600ATS P2C54ML600ATS P2C66ML600ATS P2C78ML600ATS P2C90ML600ATS P2A18ML125ATS P2A30ML125ATS P2A42ML125ATS P2A54ML125ATS P2A66ML125ATS P2A78ML125ATS P2A90ML125ATS P2A18ML250ATS P2A30ML250ATS P2A42ML250ATS P2A54ML250ATS P2A66ML250ATS P2A78ML250ATS P2A90ML250ATS P2A18ML400ATS P2A32ML400ATS P2A42ML400ATS P2A54ML400ATS P2A66ML400ATS P2A78ML400ATS P2A90ML400ATS P2A18ML600ATS P2A30ML600ATS P2A42ML600ATS P2A54ML600ATS P2A66ML600ATS P2A78ML600ATS P2A90ML600ATS P2E18ML125ATS P2E30ML125ATS P2E42ML125ATS P2E54ML125ATS P2E66ML125ATS P2E78ML125ATS P2E90ML125ATS P2E18ML250ATS P2E30ML250ATS P2E42ML250ATS P2E54ML250ATS P2E66ML250ATS P2E78ML250ATS P2E90ML250ATS P2E18ML400ATS P2E32ML400ATS P2E42ML400ATS P2E54ML400ATS P2E66ML400ATS P2E78ML400ATS P2E90ML400ATS P2E18ML600ATS P2E30ML600ATS P2E42ML600ATS P2E54ML600ATS P2E66ML600ATS P2E78ML600ATS P2E90ML600ATS P2L18ML125ATS P2L30ML125ATS P2L42ML125ATS P2L54ML125ATS P2L66ML125ATS P2L78ML125ATS P2L90ML125ATS P2L18ML250ATS P2L30ML250ATS P2L42ML250ATS P2L54ML250ATS P2L66ML250ATS P2L78ML250ATS P2L90ML250ATS P2L18ML400ATS P2L32ML400ATS P2L42ML400ATS P2L54ML400ATS P2L66ML400ATS P2L78ML400ATS P2L90ML400ATS P2L18ML600ATS P2L30ML600ATS P2L42ML600ATS P2L54ML600ATS P2L66ML600ATS P2L78ML600ATS P2L90ML600ATS Table P2-11 - Main Circuit Breaker (1)(2)(3)(4)(5) Maximum Panel Amp Rating Maximum 1-Pole Circuits 18 30 42 54 66 78 90 18 30 42 54 66 78 90 18 30 42 54 66 78 90 18 30 42 54 66 78 90 18 30 42 54 66 18 30 42 54 100 125 225 250 400 600 Box Height inches (mm) 26 32 38 44 50 56 62 26 32 38 44 50 56 62 32 38 44 50 56 62 68 38 44 50 56 62 68 74 50 56 62 66 74 56 62 68 74 Catalogue Number (2) 3Ø4W 120/208V 1Ø3W 120/240V 3Ø4W 277/480V 3Ø4W 347/600V P2C18BL100ATS P2C30BL100ATS P2C42BL100ATS P2C54BL100ATS P2C66BL100ATS P2C78BL100ATS P2C90BL100ATS P2C18E4125ATS P2C30E4125ATS P2C42E4125ATS P2C54E4125ATS P2C66E4125ATS P2C78E4125ATS P2C90E4125ATS P2C18QJ225ATS P2C32QJ225ATS P2C42QJ225ATS P2C54QJ225ATS P2C66QJ225ATS P2C78QJ225ATS P2C90QJ225ATS P2C18FX250ATS P2C30FX250ATS P2C42FX250ATS P2C54FX250ATS P2C66FX250ATS P2C78FX250ATS P2C90FX250ATS P2C18JX400ATS P2C32JX400ATS P2C42JX400ATS P2C54JX400ATS P2C66JX400ATS P2C18LX600ATS P2C30LX600ATS P2C42LX600ATS P2C54LX600ATS P2A18BL100ATS P2A30BL100ATS P2A42BL100ATS P2A54BL100ATS P2A66BL100ATS P2A78BL100ATS P2A90BL100ATS P2A18E4120ATS P2A30E4125ATS P2A42E4125ATS P2A54E4125ATS P2A66E4125ATS P2A78E4125ATS P2A90E4125ATS P2A18QJ225ATS P2A32QJ225ATS P2A42QJ225ATS P2A54QJ225ATS P2A66QJ225ATS P2A78QJ225ATS P2A90QJ225ATS P2A18FX250ATS P2A30FX250ATS P2A42FX250ATS P2A54FX250ATS P2A66FX250ATS P2A78FX250ATS P2A90FX250ATS P2A18JX400ATS P2A32JX400ATS P2A42JX400ATS P2A54JX400ATS P2A66JX400ATS P2A18LX600ATS P2A30LX600ATS P2A42LX600ATS P2A54LX600ATS P2E18BD100ATS P2E30BD100ATS P2E42BD100ATS P2E54BD100ATS P2E66BD100ATS P2E78BD100ATS P2E90BD100ATS P2E18E4125ATS P2E30E4125ATS P2E42E4125ATS P2E54E4125ATS P2E66E4125ATS P2E78E4125ATS P2E90E4125ATS P2E18E4225ATS P2E32E4225ATS P2E42E4225ATS P2E54E4225ATS P2E66E4225ATS P2E78E4225ATS P2E90E4225ATS P2E18FX250ATS P2E30FX250ATS P2E42FX250ATS P2E54FX250ATS P2E66FX250ATS P2E78FX250ATS P2E90FX250ATS P2E18JX400ATS P2E32JX400ATS P2E42JX400ATS P2E54JX400ATS P2E66JX400ATS P2E18LX600ATS P2E30LX600ATS P2E42LX600ATS P2E54LX600ATS P2L18BD100ATS P2L30BD100ATS P2L42BD100ATS P2L54BD100ATS P2L66BD100ATS P2L78BD100ATS P2L90BD100ATS P2L18E6125ATS P2L30E6125ATS P2L42E6125ATS P2L54E6125ATS P2L66E6125ATS P2L78E6125ATS P2L90E6125ATS P2L18E6225ATS P2L32E6225ATS P2L42E6225ATS P2L54E6225ATS P2L66E6225ATS P2L78E6225ATS P2L90E6225ATS P2L18FX250ATS P2L30FX250ATS P2L42FX250ATS P2L54FX250ATS P2L66FX250ATS P2L78FX250ATS P2L90FX250ATS P2L18JX400ATS P2L32JX400ATS P2L42JX400ATS P2L54JX400ATS P2L66JX400ATS P2L18LX600ATS P2L30LX600ATS P2L42LX600ATS P2L54LX600ATS (1) Refer to Pg 12, table P2-21 for breaker kits and accessories (2) Part # for Interior only (3) Refer to Pg 4 for Main breaker selection (4) Refer to Pg 5 for Branch circuit breaker selection (5) Refer to Pg 12, table P2-20 for box and trim details (6) For more number of circuits, contact local Siemens representative before ordering 6 Siemens P2 Panelboards – Selection & Application Guide Modifications* P2 Panel Options Enclosures • Extra gutter to sides or ends of the can • 24" wide boxes • Hinged trims* • Door-in-door trims* • Screw to the box trims* • Trim mounted devices (Devices mounted and wired to the trim should also have hinged trim specified) • Pilot lights • Toggle switches • Push buttons • Painted boxes • Custom colors • Increase gauge trims and boxes* • Stainless steel trims and boxes, Type 1* Panel Modifications • Main Bus Standard main bus is temperature rated tin-plated aluminum. Bus options are 750 A/Si aluminum, tin-plated temperature rated copper tin-plated standard – silver optional. 1000 A/Si copper tin-plated standard – silver optional. Includes copper neutral cross bar. For copper neutral branch lugs, see miscellaneous. • Split bus adds 6” to unit space* • Compression lug for MLO* • Compression lugs on main breaker (may require extra width or length on enclosure).* • Contactor mains or submain* • Asco 920 through 225 amps. Adds 12” unit space as main, 15” unit space as submain.* • Asco 911 through 150 amps. Adds 21” unit space.* • Siemens LEN through 30 amps. Adds 12” unit space.* Makes box 10" deep. • Control power transformers (contact engineering for extra* gutter requirements) • Branch and main breaker accessories • Handle blocks • Handle locks • Aux. Contacts 1 • UVR 1 • Feed-thru lugs • 200% neutral • Copper lugs, mechanical • Bus mounted TVSS • Service entrance labeled P2 Panelboards • Aluminum trims and boxes, Type 1* • NEMA 3R/12 enclosures • NEMA 4 enclosures • NEMA 4X enclosures • Special keyed locks* • Gasketing trim to box • Panel skirts • Grounding of panelboards Ground bars are shipped with the panel interior factory mounted. • Non-insulated equipment ground bar – standard • Copper non-insulated ground bar • Aluminum insulated equipment ground bar • Copper insulated equipment ground bar • Shunt trip on main or branch BL, BLH, HBL, ED2, ED4, HED4, HED6, HHED6 uses 1” unit space for shunt trip. All may be used on mains or subfeeds. QJ2, QJ2-H, QJH2, HQJ2H, ED2, ED4, ED6, HED4, HED6, FXD6, HFD6, JXD6, JD6, HJD6, HJXD6 • Remote control switches – mounted in a 23” enclosure to be cable connected to the panel. • Time clocks – mounted in a 23” enclosure to be cable connected to the panel. Sangamo, tork or paragon time clock can be supplied and mounted in panelboard cabinet. 1 Accessories on 1" pole breakers (BL, BQD, ED) will take unit space. *Contact local Siemens representative for any options & modifications. Siemens P2 Panelboards – Selection & Application Guide 7 Modifications* P2 Panelboards Table P2-12 – Box Size Additions (In.) For Optional Features Main Lugs 125A 250A Main Breakers 400A 600A 6 (all) 6 (all) Options 200 Neutral (lug type) Std. Lugs (100% Neut. PNL) CU Lugs (100% Neut. PNL) Comp Lugs (100% Neut. PNL) Feed-thru Standard Lugs Feed-thru Cu Lugs Feed-thru Comp Lugs Subfeed Standard Lugs Split Bus (1) FD Subfeed (Horizontal Mtg.) (2) FD Subfeed (Vertical Mtg.) TVSS 0 0 0 0 0 6 6 6 125A 125A Horiz. Horiz. BL,BQD,ED CED 125A Vert. ED 225A Vert. QJ 250A Vert. FD 250A Vert. CFD 400A JD 600A LD 600A CLD 0 0 0 6 6 0 0 0 0 0 0 0 0 0 6 6 0 0 0 0 0 6 0 6 6 0 6 6 0 0 0 0 0 6 6 6 6 6 0 6 6 0 0 0 0 0 6 6 6 6 12 12 12 N/A 6 6 6 6 6 6 6 6 6 6 6 6 12 12 12 12 12 12 12 N/A 6 12 12 N/A 6 6 6 6 12 12 12 12 12 N/A 0 6 6 N/A — — — — — — — — — — 6 6 6 6 6 6 6 6 6 6 6 6 6 6 N/A 12 12 12 N/A N/A N/A N/A 12 12 12 12 12 12 N/A 24 24 24 N/A N/A N/A N/A 24 24 24 24 24 24 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Split bus is paired with feed-thru lugs by default. Feed-thru lugs are to feed the section after the split. NOTE: N/A = OPTION NOT AVAILABLE *Contact local Siemens representative before any modification. 8 400A CJD Siemens P2 Panelboards – Selection & Application Guide Connector Modifications P2 Panelboards Compression Lugs Table P2-13 – Lugs Style Amp Rating Breaker Type Compression Connectors Box Height Addition MLO 125 250 400 N/A N/A N/A 6 6 6 600 N/A 100 ED4, ED6, HED4 CED6 QJ2, QJH2, QJ2H FXD6, HFD6, CFD6 (1)#6 - 350 Kcmil Al/Cu (1)#6 - 350 Kcmil Al/Cu (1) 400 - 600 Kcmil Cu or (2)#6 - 350 Kcmil Al/Cu (2)#6 - 350 Kcmil Cu or Cu/Al or 400 - 600 Kcmil Al/Cu (1)#14-2/0 AWG Cu or Al 225 Main Breaker 400 600 JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, SCJD6 LD6, LXD6, HLD6, CJD6, SLD6, SHLD6, SCLD6 6 (2)#1/0 AWG - 500 Kcmil Cu or Al Box must go to 24” wide on CED6 breaker only Add 6” to box height for NØ Box must go to 24” wide Box must go to 24” wide for all breakers Requires an additional 6.0” box height 9 (2)#2/0 AWG - 500 Kcmil Cu or Al 6 (1)#6 AWG - 350 Kcmil Cu or Al (1)#6 AWG - 350 Kcmil Cu or Al Table P2-14 – Alternate Lugs* Style Amp Rating Breaker Type Compression Connectors Box Height Addition MLO 400 N/A (1) 250 - 750 Kcmil or (2)#3/0 AWG - 250 Kcmil Cu or Al 6 Main Breaker 400 JD6, JXD6, HJD6, CJD6, SJD6, SHJD6, SCJD6 (1)#4/0 AWG - 750 Kcmil Cu or Al 6 *Contact local Siemens representative for any modifications. Siemens P2 Panelboards – Selection & Application Guide 9 Connector Modifications P2 Panelboards Enclosure Modifications NEMA-4 For Type P2* Water Tight, Dust Tight, Steel Enclosure Table P2-15 Box Height Inches 26 32 38 44 50 56 62 68 74 80 NEMA-4X For Type P2* Water Tight, Dust Tight and Corrosion Resistant Table P2-16 Enclosure Size H W 30 24 36 24 42 30 48 36 60 36 60 36 66 36 72 36 78 36 84 36 D 8 8 8 8 8 8 8 8 8 8 Box Height Inches 26 32 38 44 50 56 62 68 74 80 Enclosure - Stainless Steel and Steel with Epoxy Coating Enclosure - Fiberglass Size (inches) H 30 36 48 48 60 60 66 72 78 84 H 30 36 48 48 60 60 72 72 84 84 W 24 24 36 36 36 36 36 36 36 36 D 8 8 8 8 12 12 8 8 8 8 D 24 24 36 36 36 36 36 36 36 36 W 8 8 12 12 12 12 8 8 8 8 Remote Switch Modifications Table P2-17 – Control Power* Transformer Size VA 0,1 2 3 4 50 75 150 250 Table P2-18 – Application For Remote Switch* Switch Type Modification 920 Adds 12” to unit space ≤ 225A adds 21” unit space >225 ≤400 Amps add 10” to width and 8” DP minimum and 24” to height 30A adds 15” to unit space >30A 100 adds 12” to unit space 7.7 Dp. Box min. 100 A ≤ 200 adds 12” to unit space and 10” DP. min. 911 LEN Table P2-19 – Remote Control Switch Modification* Description Auxiliary Contacts (Mounted Not Wired) Ea. 2-Wire Control *Contact local Siemens representative for any modifications. 10 Siemens P2 Panelboards – Selection & Application Guide Dimensions P2 Panelboards Type 1 Box Box is symmetrical Type 3R/12 Box 1 Dimensions are interior of the box. Add 5/8” to width for absolute dimension. Add 1/8” to height for absolute dimension. Dimensions shown in inches and millimeters [ ]. Siemens P2 Panelboards – Selection & Application Guide 11 Kits and Accessories P2 Panelboards Table P2-20 – Standard Enclosures Catalogue Number Box Height Inches Type 1 Standard Trim Box Surface Flush Type 2 Standard Trim Box Surface 26 32 38 44 50 56 62 68 74 B26 B32 B38 B44 B50 B56 B62 B68 B74 S26B S32B S38B S44B S50B S56B S62B S68B S74B F26B F32B F38B F44B F50B F56B F62B F68B F74B DSB52026 DSB52032 DSB52038 DSB52044 DSB52050 DSB52056 DSB52062 DSB52068 DSB52074 S26B S32B S38B S44B S50B S56B S62B S68B S74B Type 3R/12 (1) Complete Enclosure With Hinged Cover WP26 WP32 WP38 WP44 WP50 WP56 WP62 WP68 WP74 Options for Type 1 & 2 Tubs Add suffix "K" for enclosure c/w tub end wall with knockouts Add suffix "KN" for enclosure c/w tub end wall with knockouts and gasketed Add suffix "N" for enclosure gasketed Add suffix "P" for enclosure painted std grey Add suffix "PK" for enclosure painted std grey c/w tub end wall with knockouts Add suffix "PKN" for enclosure painted std grey c/w tub end wall with knockouts and gasketed Add suffix "PN" for enclosure painted std grey and gasketed Add suffix "M" for metal card holder Hinged trim - Replace "B" suffiz with "H" Door-in-door - Replace "B" suffix with "D" Metal card holder – Add “M” suffix Option For 24” Wide Enclosures with Equal Gutter on Both Sides 24” wide with equal gutter on both sides - Add “24” as prefix (1) For Silicon free enclosure, contact local Siemens representative. Table P2-21 – Breaker Kits and Accessories (1) Kit No. Description BBKB32AT BL/BQD 6-pole 3” branch breaker kit BBKED32AT ED 6-pole 3” branch breaker kit QJ branch breaker kit for 2 and BBKQ1AT 3-pole single mount BL, BQD, ED deadfront kit for DFK1 1” pole breakers DFFP3 Deadfront filler 3” DFFP6 Deadfront filler 6” BNK2 Branch neutral (P2) P2BK1 P2 250A max. Bonding Kit P2BK2 P2 400A max. Bonding Kit P2BK3 P2 600A max. Bonding Kit BBKB32CS BL/BQD 6-pole 3” branch breaker kit Contents Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware (Al/Tin) Kit contains breaker support, inter-phase barriers, (3) A/C connectors, (1) B connector, hardware (Al/Tin) Kit to contain all connectors and cover plates necessary to mount both 2 and 3-pole breakers (Al/Tin) Center strips 3”, 6”, 9,” 15,” 21” plus mounting hardware 3” empty space filler and hardware 6” empty space filler and hardware Three tier lug with mounting hardware to increase neutral capacity Bonding strap and hardware Bonding strap and hardware Bonding strap and hardware Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware (Cu/Silver) BBKED32CS ED 6-pole 3” branch breaker kit Kit contains breaker support, inter-phase barriers, (3)A/C connectors, (1)B connector, hardware (Cu/Silver) QJ branch breaker kit for 2 and 3-pole single mount Kit to contain all connectors and cover plates necessary to mount both 2 and 3-pole breakers (Cu/Silver) BBKQ1CS (1) For CEDG branch breaker kit, contact local Siemens representative 12 Siemens P2 Panelboards – Selection & Application Guide S I E M E N S I N C A N A D A Siemens is one of the largest and most diversified companies in the world, providing innovations in areas such as health care, information & communications, energy & power, industry & automation, transportation and lighting. In Canada, Siemens is headquartered in Mississauga, Ontario, and has 73 offices and nine manufacturing facilities across the country. Locations span from coast to coast, staffed by more than 6,200 employees. I N D U S T RY A N D AU T O M AT I O N I N H E A L T H C A R E , we provide complete integrated solutions, from diagnostic imaging equipment, telemedicine solutions, clinical networking systems and patient monitoring/life support systems to consultative services and staff training. These offerings not only improve patient care but also increase administrative, financial and clinical efficiencies and streamline workflow processes. As the world’s largest manufacturer of hearing instruments, Siemens offers assistive listening devices that improve quality of life for the hard of hearing. P2 PANELBOARDS SELECTION & APPLICATION GUIDE I N I N F O R M A T I O N & C O M M U N I C A T I O N S , we continue to focus on an ever-widening range of network technologies including the engineering and integration of next generation voice, data, standard and wireless applications. In the Canadian cellular market, Siemens is breaking new ground in establishing GSM services with a strong GSM/GPRS portfolio. We offer complete solutions for network access, optical switching and core routing technologies and we are a leading provider of single-source IT consulting solutions and management services for supply chain, enterprise resource, business information and customer relationship. I N E N E R G Y & P O W E R , we supply reliable power solutions, from generation and distribution to control and automation applications. We provide the most responsive sources of solutions to improve the competitiveness and profitability of our customers’ operating plants. 1.0_04/04_A&D-1305 I N I N D U S T R Y & A U T O M A T I O N , we offer integrated automation solutions to increase productivity at all levels of industry, from component-level support and simple process control to designing, building, commissioning, servicing and maintaining integrated plant systems. To help our customers manage their facilities more efficiently, we provide building maintenance services and control systems from fire alarms to climate control. We also offer a full range of postal automation systems and support services. I N T R A N S P O R T A T I O N , Siemens offers a wide range of rail vehicles, from complete transportation systems and people movers to rolling stock for light rail, heavy rail and subways. In addition, we supply all major transportation system elements, such as train control, systems electrification and systems maintenance. For the automotive industry, we have developed a new technology involving electronically controlling engine acoustics via the air intake system. Your local contact is: I N L I G H T I N G , through OSRAM SYLVANIA LTD., we are a leader in the Canadian lighting market, dedicated to setting new market standards in commercial & industrial, consumer, automotive, specialty and lighting services. I N F I N A N C I N G , we provide a full range of customized financial services for the acquisition of capital equipment and services. We offer complete financial solutions including: loans; leases; project funding; financial expertise; technology leases and customized applications. Siemens Canada Limited Automation & Drives 1550 Appleby Line, Burlington, ON L7L 6X7 Customer Interaction Centre Tel: (888) 303-3353 For further innovations visit www.siemens.ca 2004
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 14 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:01364a60-97b1-11d8-9426-003065d50134 Producer : Acrobat Distiller 6.0 for Macintosh Create Date : 2004:04:26 14:35:31-04:00 Modify Date : 2004:04:26 14:39:09-04:00 Creator Tool : QuarkXPress(tm) 5.0 Metadata Date : 2004:04:26 14:39:09-04:00 Document ID : uuid:8505e1a5-97b0-11d8-b043-003065d50134 Format : application/pdf Creator : Colin Aitken Title : 16294 P2 Panelboards Author : Colin AitkenEXIF Metadata provided by EXIF.tools