SIEMENS IN CANADA Siemens is one of the largest and most diversified
companies in the world, providing innovations in areas such as health care, information
& communications, energy & power, industry & automation, transportation and lighting.
In Canada, Siemens is headquartered in Mississauga, Ontario, and has 73 offices and
nine manufacturing facilities across the country. Locations span from coast to coast,
staffed by more than 6,200 employees.
IN HEALTH CARE, we provide complete integrated solutions, from diagnostic
imaging equipment, telemedicine solutions, clinical networking systems and patient
monitoring/life support systems to consultative services and staff training. These offerings
not only improve patient care but also increase administrative, financial and clinical
efficiencies and streamline workflow processes. As the world’s largest manufacturer of
hearing instruments, Siemens offers assistive listening devices that improve quality of
life for the hard of hearing.
IN INFORMATION & COMMUNICATIONS, we continue to focus on an
ever-widening range of network technologies including the engineering and integration
of next generation voice, data, standard and wireless applications. In the Canadian
cellular market, Siemens is breaking new ground in establishing GSM services with a
strong GSM/GPRS portfolio. We offer complete solutions for network access, optical
switching and core routing technologies and we are a leading provider of single-source
IT consulting solutions and management services for supply chain, enterprise resource,
business information and customer relationship.
IN ENERGY & POWER, we supply reliable power solutions, from generation
and distribution to control and automation applications. We provide the most responsive
sources of solutions to improve the competitiveness and profitability of our customers’
operating plants.
IN INDUSTRY & AUTOMATION, we offer integrated automation solutions
to increase productivity at all levels of industry, from component-level support and simple
process control to designing, building, commissioning, servicing and maintaining
integrated plant systems. To help our customers manage their facilities more efficiently,
we provide building maintenance services and control systems from fire alarms to climate
control. We also offer a full range of postal automation systems and support services.
IN TRANSPORTATION, Siemens offers a wide range of rail vehicles, from
complete transportation systems and people movers to rolling stock for light rail, heavy
rail and subways. In addition, we supply all major transportation system elements, such
as train control, systems electrification and systems maintenance. For the automotive
industry, we have developed a new technology involving electronically controlling
engine acoustics via the air intake system.
IN LIGHTING, through OSRAM SYLVANIA LTD., we are a leader in the Canadian
lighting market, dedicated to setting new market standards in commercial & industrial,
consumer, automotive, specialty and lighting services.
IN FINANCING, we provide a full range of customized financial services for the
acquisition of capital equipment and services. We offer complete financial solutions
including: loans; leases; project funding; financial expertise; technology leases and
customized applications.
2004
Customer Interaction Centre
Tel: (888) 303-3353
Siemens Canada Limited
Automation & Drives
1550 Appleby Line, Burlington, ON L7L 6X7
For further innovations visit www.siemens.ca
P2 PANELBOARDS SELECTION & APPLICATION GUIDE
INDUSTRY AND AUTOMATION
1.0_04/04_A&D-1305
Your local contact is:
General Information 2
Selection and Application 2
Application 3-5
Panel Unit Space To Box Height Requirements 3
Main Lug Connectors 3
Branch Breaker Side Gutters 3
Main Breaker Selection 4
Subfeed Breakers 4
Branch Circuit Breakers 5
Branch Neutral Connections 5
Typical Catalogue Numbers 6
Main Lugs Only 6
Main Circuit Breakers 6
Standard Modifications 7
Box Size Additions For Optional Features 8
Connector Modifications 9-10
Compression Lugs 9
Enclosure Modifications 10
Remote Switch Modifications 10
Dimensions 11
Kits and Accessories 12
Description Page Description Page
P2 Panelboards
Flexibility is the hallmark of the P2 panel. This panel offers a
wide array of factory-assembled options to meet almost all light-
ing panel applications. With this design, the ability to mix breaker
frames in unit space up to 250 amps will also meet many distri-
bution panel requirements in a much smaller package. Busing
options for the P2 vary from the typical temperature rated to
750 A/Si aluminum to 1000A/Si copper. Standard busing in
the P2 panel is tin-plated. Silver-plated copper is also offered
as an option. Integrated time clocks, bus mounted contactors,
as mains or sub mains, split bus, and subfeed lugs (up to 400
amp) are just a few of the options of this unique panel.
Like a lighting panel, P2 is set up around 18, 30, 42, and 54
circuit configurations. It will also allow the user to configure
the panel to the smallest possible size. The P2 panel starts
with 9” of unit space (18 circuits of 1” pole breakers). Breakers
mounted in unit space can be mixed and matched to meet
customer requirements. All 1” pole breakers (BL, BQD, ED
frames) are mounted in 3” or 6” pole increments. Breaker
frames, above 125 amps, are mounted in 6” single breaker
mountings. As an example of a minimum panel, (6) 20 amp
1-pole BL breakers (3” of unit space) and a 3-pole 225 amp
QJ breaker (6” of unit space) equaling 9” of unit space can be
configured in a P2 panel without any extra provisions or space
required. FD 250 amp and JD 400 amp breakers are mounted
as subfeed breakers outside of unit space.
Another unique feature of the P2 panel is that blank unit space
can be added to allow for future expansions or modifications.
Any expansions or modifications must be in 3” increments. BL,
BQD, and ED frame breakers have 3” or 6” pole kits, and can be
mixed in unit space by these increments. Breakers of the same
frame can cross from one mounting to another if contiguous. QJ
frame breakers are mounted in 6” increments for two and three
pole, single mounted units. Changes in the unit space length for
BL, BQD, or ED frame breakers require an addition deadfront,
center strip kit. Check with sales or the factory for additional
unit space kits.
Main Lug / Main Breaker
Enclosure – Standard Type 1 enclosure is 20" wide x 5.75"
deep X. Box Height is determined by main device and unit
space. See charts for box height.
Voltage – 600 Vac Max.
250 Vdc Max.
Amperage – 600 amp Max.
Short circuit rating – 200 KAIC Max. symmetrical or equal
to the lowest rated device installed unless a series rating is
indicated. Panels with subfeed or feed-thru lugs without a
main device, circuit breaker or fusible unit, are limited to a
three-cycle rating. The three-cycle rating for the P2 panel
is limited to 22 KAIC. Note that the main device may be
mounted remote from the panel.
Busing – The P2 panel has more options to meet market
requirements. The standard busing is temperature rated
aluminum. The rating is per the requirements of CSA: 22.2
No. 29 – the standard for panelboards. All aluminum busing
is tin-plated. Optional busing for the P2 panel is: 750 A/Si
aluminum, temperature rated copper, and 1000 A/Si copper.
The copper bus option for this panel is tin-plated.
Weight Approximate
Total panelboard weight when filled with a normal quantity
of breakers and accessories is about 3 lbs. (1 kg) per inch
(54g per mm) of box height.
Dimensions in inches (mm) Gauge Steel
Width Height Box Front
20” 26 - 74 #16 #14
(508) (660, 1880)
Table P2-1 – Gauge Steel of Boxes
Fronts, Surface and Flush
Selection and Application
Step 1
Determine configuration required.
Example:
Amperage 250A
Voltage 208Y/120V
System 3Ø4W
Main Main Lug
Bus Material Temperature
rated aluminum
Interrupt Rating 10 Ka
Branch Devices (6) 20 amp,1-pole
(1) 225 amp, 3-pole
Feed Location Top
Mounting Surface
Step 2
Create a catalogue number by following
the Catalogue Numbering System on page
6. Note that the number of circuits num-
ber (4th and 5th position) will be 18 for
those panels with 6-18 circuits, 30 for
those panels with 19-30 circuits, 42 for
those panels 31 to 42 circuits and 54 for
those panels 43 to 54 circuits. The most
cost effective 20 amp 1-pole breaker for
this application would be BL. However,
a myriad of other breakers with options
may be used in the P2 panel. The most
cost effective 225 amp breaker for this
application is the QJ2.
Based on the above
P2C18ML250ATS
(6) BL 20 amp 1-Pole
(1) QJ2 225 amp 3-pole
Step 3
Determine the enclosure size. The matrix
on page 2-3 shows the enclosure sizes
based on the amperage, main device and
unit space required.
P2 Panelboards
Siemens P2 Panelboards – Selection & Application Guide
P2 Panelboards
2
Table P2-2 – Panel Unit Space To Box Height Requirements
P2 Panels With Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension
“B” Main Lugs Main Breakers
Dimen-
sion 125A 250A 400A 600A 125A 125A 125A 225A 250A 250A 400A 400A 600A 600A
Box Horiz. Horiz. Vert. Horiz. Horiz. Vert. JD CJD LD CLD
Height BL,BQD,ED CED ED QJ FD CFD
26 9 9 ———— —— ——
32 15 9 — — 15 9 9 9 — — -—
38 21 15 9 9 21 15 15 15 9
44 27 21 15 15 27 21 21 21 15
50 33 27 21 21 33 27 27 27 21 9 9
56 39 33 27 27 39 33 33 33 27 15 15 9 —
62 45 39 33 33 45 39 39 39 33 21 21 9 15 9
68* 51* 45 39 39 51* 45 45 45 39 27 27 15 21 15
74* 57* 51* 45 45 57* 51* 51* 51* 45 33 33 21 27 21
Table P2-4 – Main Lug Connectors (Fig. P2-2)
Panel Amps Standard Connectors C D
125 (1) #14 - 2/0 6.62 8.19
250 (1) #6 AWG - 350 Kcmil 12.34 11.22
400 (1) #4 AWG - 600 Kcmil 14.00 13.09
or (2) #6 - 250 Kcmil
600 (2) #4 AWG - 500 Kcmil 14.00 11.00
Table P2-3 – Main Breaker (Fig. P2-1)
Panel Amps Breaker Frames C D
100 BL 5.75 8.00
BQD 5.125 8.00
125 ED 4.00 8.00
225 QJ 5.00 7.00
250 FD 5.00 7.00
400 JD 14.00 25.00
600 LD 15.50 23.00
Fig. P2-3
Fig. P2-1 Fig. P2-2
Box depth = 5.75 in. (146 mm)
Box width – 20 in. (508 mm)
for 100-600A
Box depth = 5.75 in. (146 mm)
Box width – 20 in. (508 mm)
for 100-600A
Table P2-5 – Branch Breaker Side
Gutters Inches (mm) (Fig. P2-3)
Reference Panel
Letter Width 20” (508)
A5.750 (146)
B5.125 (130)
C4.000 (102)
D 15.000 (127)
1Single branch mounting construction.
BL, BLH, HBL BL, BLH, HBL
BLF, BLFH BLF, BLFH
BQD, BQD6 BQD, BQD6
ED, ED4, ED6 ED, ED4, ED6
HED4 HED4
A
Panel Width
20 in. (508 mm)
QJ2,QJH2, QJ2-H, HQJ2H
(Single Mounted)
A
BB
CC
DD
P2 Panelboards
Application
Siemens P2 Panelboards – Selection & Application Guide 3
*Contact local Siemens representative before ordering.
Table P2-6 – Main Breaker Selection 1
Ampere Breaker Maximum Interrupting Rating (kA)
Rating Type 240V 480V 600V Available Trip Values
BL (STD) 10 —
HBL 65 14
BQD (STD 480/277 Vac) 65 18
100 ED4 65 25 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 90, 100
ED6 100 42 18
HED4 100 65
CED6 200 200 100
ED4 (STD) 65 18
ED6 65 25 18
125 HED4 100 42 125
CED6 200 200 100
QJ2 (STD) 10 —
QJH2 22 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225
QJ2H 42 —
225 FD6, FXD6 65 35 18
HFD6, HFXD6 100 65 25 70, 80, 90, 100, 110, 125, 150, 175, 200, 225
CFD6 200 150 100
FD6, FXD6 (STD) 65 35 18
250 HFD6, HFXD6 100 65 25 250
CFD6 200 150 100
JXD6 (STD), JD6 65 35 25 200, 225, 250, 300, 350, 400
400 HJD6, HJXD6 100 65 35 200, 225, 250, 300, 350, 400
SJD6 65 35 25 200, 300, 400
CJD6,SCJD6 200 200 100 200, 300, 400
LXD6 (STD) 65 35 25 450, 500, 600
LD6 65 35 25 250, 300, 350, 400, 450, 500, 600
600 HLD6, HLXD6 100 65 35 250, 300, 350, 400, 450, 500, 600
SLD6, 65 35 25 300, 400, 500, 600
SHLD6 100 65 35 300, 400, 500, 600
CLD6, SCLD6 200 150 100 300, 400, 500, 600
1Interchangeable trip main breakers are mounted at top of panel only.
1 Twin mounted subfeed breakers are mounted at bottom of panelboard only and adds 24" to the panel height.
2 Subfeed breaker is mounted at bottom of panelboard only. 400 amp subfeed breaker adds 30" to the panel height.
Table P2-7 – Subfeed Breakers
Mounting Position Maximum Interrupting
Breaker When Used As Subfeed Breaker Rating (kA) Symmetrical
Type Vertical Ampere Ratings For Load 240V AC 480V AC 600V DC
FD6 1, FXD6 Twin 70 - 250 65 35 18
HFD61, HFXD6 Twin 70 - 250 100 65 25
JD6 2, JXD6 Single 200 - 400 65 35 25
HJD6 2, HJXD6 Single 200 - 400 100 65 35
P2 Panelboards
Siemens P2 Panelboards – Selection & Application Guide
Application
4
P2 Panelboards
Application
Siemens P2 Panelboards – Selection & Application Guide 5
Table P2-8 – Branch Circuit Breakers
Max. Bolt-On No. Maximum Interrupting Rating (kA)
Amp Breaker of Amp Volts – AC DC
Rating Type Poles Rating 120 120/240 240 277 480 600 250
1 15 - 70 10
BL 2 15 - 100 10
3 15 - 100 10
BL, HID 1 15 - 30 10
2 15 - 30 10
BLR 2 15 - 100 10
BLE 1 15 - 30 10
2 15 - 60 10
BLEH 1 15 - 30 22
2 15 - 60 22
BLF 1 15 - 30 10
2 15 - 60 10
100 BLHF 1 15 - 30 22
3 15 - 60 22
BGL 12 15 - 30 10
3 15 - 30 10
BAF 1 15, 20 10
BAFH 1 15, 20 22
1 15 - 70 22
BLH 2 15 - 100 22
3 15 - 100 22
1 15 - 70 65
HBL 2 15 - 100 65
3 15 - 100 65
1—651414
BQD 2 15 - 100 65 14 14
3—651414
ED2 1 15 - 100 10
2/3 10 5 (2-P)
ED4 1 15 - 125 65 22
2—651830
3—6518
ED6 2 15 - 125 65 25 18 30
125
3 65 — 25 18
1—
*CED6 2 15 - 125 200 200 200 200 100
3 — 200 200 200 200 100 50
QJ2 2/3 60 - 225 10
225 QJH2 2/3 60 - 225 22
QJ2-H 2/3 60 - 225 42
HQJ2H 2/3 100 - 225 100
Branch Device Limitations
For panels applied on systems requiring neutral connections,
some limitations apply. By application rule (NEC 480.14) lighting
and appliance panels are limited to 42 circuits installed. Each
overcurrent device pole counts as a circuit. Additional limitations
for these panels are based on available neutral connections.
Table P2-9 – Branch Neutral Connections
Wire Range Max. Number of Connections Max. Amps 1
#14-#6 26 65
#14-1/0 28 125
#6 - 350 Kcmil 3 250
(1) #4-600 Kcmil 1 400
or (2) #6-250 Kcmil
1 Two pole breaker is one phase and neutral. Three pole is two phase and neutral.
NOTE: QJ Breakers are single mounted in unit space and take 6” of unit space.
Limited to (3) per panel max. BL, HBL, BLH and BQD breakers are mounted in
common mountings in 3” or (6) pole increments. ED2, ED4, ED6 and HED4 breakers
are mounted in common mountings in 3” or (6) pole increments.
1Based on 75 degree copper.
*Contact local Siemens representative before ordering.
Table P2-11 - Main Circuit Breaker (1)(2)(3)(4)(5)
P2 Panelboards
Siemens P2 Panelboards – Selection & Application Guide
Typical Catalogue Numbers
6
18 26 P2C18BL100ATS P2A18BL100ATS P2E18BD100ATS P2L18BD100ATS
30 32 P2C30BL100ATS P2A30BL100ATS P2E30BD100ATS P2L30BD100ATS
42 38 P2C42BL100ATS P2A42BL100ATS P2E42BD100ATS P2L42BD100ATS
100 54 44 P2C54BL100ATS P2A54BL100ATS P2E54BD100ATS P2L54BD100ATS
66 50 P2C66BL100ATS P2A66BL100ATS P2E66BD100ATS P2L66BD100ATS
78 56 P2C78BL100ATS P2A78BL100ATS P2E78BD100ATS P2L78BD100ATS
90 62 P2C90BL100ATS P2A90BL100ATS P2E90BD100ATS P2L90BD100ATS
18 26 P2C18E4125ATS P2A18E4120ATS P2E18E4125ATS P2L18E6125ATS
30 32 P2C30E4125ATS P2A30E4125ATS P2E30E4125ATS P2L30E6125ATS
42 38 P2C42E4125ATS P2A42E4125ATS P2E42E4125ATS P2L42E6125ATS
125 54 44 P2C54E4125ATS P2A54E4125ATS P2E54E4125ATS P2L54E6125ATS
66 50 P2C66E4125ATS P2A66E4125ATS P2E66E4125ATS P2L66E6125ATS
78 56 P2C78E4125ATS P2A78E4125ATS P2E78E4125ATS P2L78E6125ATS
90 62 P2C90E4125ATS P2A90E4125ATS P2E90E4125ATS P2L90E6125ATS
18 32 P2C18QJ225ATS P2A18QJ225ATS P2E18E4225ATS P2L18E6225ATS
30 38 P2C32QJ225ATS P2A32QJ225ATS P2E32E4225ATS P2L32E6225ATS
42 44 P2C42QJ225ATS P2A42QJ225ATS P2E42E4225ATS P2L42E6225ATS
225 54 50 P2C54QJ225ATS P2A54QJ225ATS P2E54E4225ATS P2L54E6225ATS
66 56 P2C66QJ225ATS P2A66QJ225ATS P2E66E4225ATS P2L66E6225ATS
78 62 P2C78QJ225ATS P2A78QJ225ATS P2E78E4225ATS P2L78E6225ATS
90 68 P2C90QJ225ATS P2A90QJ225ATS P2E90E4225ATS P2L90E6225ATS
18 38 P2C18FX250ATS P2A18FX250ATS P2E18FX250ATS P2L18FX250ATS
30 44 P2C30FX250ATS P2A30FX250ATS P2E30FX250ATS P2L30FX250ATS
42 50 P2C42FX250ATS P2A42FX250ATS P2E42FX250ATS P2L42FX250ATS
250 54 56 P2C54FX250ATS P2A54FX250ATS P2E54FX250ATS P2L54FX250ATS
66 62 P2C66FX250ATS P2A66FX250ATS P2E66FX250ATS P2L66FX250ATS
78 68 P2C78FX250ATS P2A78FX250ATS P2E78FX250ATS P2L78FX250ATS
90 74 P2C90FX250ATS P2A90FX250ATS P2E90FX250ATS P2L90FX250ATS
18 50 P2C18JX400ATS P2A18JX400ATS P2E18JX400ATS P2L18JX400ATS
30 56 P2C32JX400ATS P2A32JX400ATS P2E32JX400ATS P2L32JX400ATS
42 62 P2C42JX400ATS P2A42JX400ATS P2E42JX400ATS P2L42JX400ATS
400 54 66 P2C54JX400ATS P2A54JX400ATS P2E54JX400ATS P2L54JX400ATS
66 74 P2C66JX400ATS P2A66JX400ATS P2E66JX400ATS P2L66JX400ATS
18 56 P2C18LX600ATS P2A18LX600ATS P2E18LX600ATS P2L18LX600ATS
30 62 P2C30LX600ATS P2A30LX600ATS P2E30LX600ATS P2L30LX600ATS
42 68 P2C42LX600ATS P2A42LX600ATS P2E42LX600ATS P2L42LX600ATS
600 54 74 P2C54LX600ATS P2A54LX600ATS P2E54LX600ATS P2L54LX600ATS
Maximum
Panel
Amp Rating
Maximum
1-Pole
Circuits
Box
Height
inches (mm)
3Ø4W 120/208V 1Ø3W 120/240V 3Ø4W 277/480V 3Ø4W 347/600V
Catalogue Number (2)
Table P2-10 – Main Lugs Only (1)(2)(4)(5)
18 26 P2C18ML125ATS P2A18ML125ATS P2E18ML125ATS P2L18ML125ATS
30 32 P2C30ML125ATS P2A30ML125ATS P2E30ML125ATS P2L30ML125ATS
125 42 38 P2C42ML125ATS P2A42ML125ATS P2E42ML125ATS P2L42ML125ATS
54 44 P2C54ML125ATS P2A54ML125ATS P2E54ML125ATS P2L54ML125ATS
66 50 P2C66ML125ATS P2A66ML125ATS P2E66ML125ATS P2L66ML125ATS
78 56 P2C78ML125ATS P2A78ML125ATS P2E78ML125ATS P2L78ML125ATS
90 62 P2C90ML125ATS P2A90ML125ATS P2E90ML125ATS P2L90ML125ATS
18 32 P2C18ML250ATS P2A18ML250ATS P2E18ML250ATS P2L18ML250ATS
30 38 P2C30ML250ATS P2A30ML250ATS P2E30ML250ATS P2L30ML250ATS
250 42 44 P2C42ML250ATS P2A42ML250ATS P2E42ML250ATS P2L42ML250ATS
54 50 P2C54ML250ATS P2A54ML250ATS P2E54ML250ATS P2L54ML250ATS
66 56 P2C66ML250ATS P2A66ML250ATS P2E66ML250ATS P2L66ML250ATS
78 62 P2C78ML250ATS P2A78ML250ATS P2E78ML250ATS P2L78ML250ATS
90 68 P2C90ML250ATS P2A90ML250ATS P2E90ML250ATS P2L90ML250ATS
18 38 P2C18ML400ATS P2A18ML400ATS P2E18ML400ATS P2L18ML400ATS
30 44 P2C32ML400ATS P2A32ML400ATS P2E32ML400ATS P2L32ML400ATS
400 42 50 P2C42ML400ATS P2A42ML400ATS P2E42ML400ATS P2L42ML400ATS
54 56 P2C54ML400ATS P2A54ML400ATS P2E54ML400ATS P2L54ML400ATS
66 62 P2C66ML400ATS P2A66ML400ATS P2E66ML400ATS P2L66ML400ATS
78 68 P2C78ML400ATS P2A78ML400ATS P2E78ML400ATS P2L78ML400ATS
90 74 P2C90ML400ATS P2A90ML400ATS P2E90ML400ATS P2L90ML400ATS
18 38 P2C18ML600ATS P2A18ML600ATS P2E18ML600ATS P2L18ML600ATS
30 44 P2C30ML600ATS P2A30ML600ATS P2E30ML600ATS P2L30ML600ATS
600 42 50 P2C42ML600ATS P2A42ML600ATS P2E42ML600ATS P2L42ML600ATS
54 56 P2C54ML600ATS P2A54ML600ATS P2E54ML600ATS P2L54ML600ATS
66 62 P2C66ML600ATS P2A66ML600ATS P2E66ML600ATS P2L66ML600ATS
78 68 P2C78ML600ATS P2A78ML600ATS P2E78ML600ATS P2L78ML600ATS
90 74 P2C90ML600ATS P2A90ML600ATS P2E90ML600ATS P2L90ML600ATS
Maximum
Panel
Amp Rating
Maximum
1-Pole
Circuits (6)
Box
Height
inches (mm)
3Ø4W 208Y/120V 1Ø3W 120/240V 3Ø4W 480Y/27V 3Ø4W 347/600V
Catalogue Number (2)
(1) Refer to Pg 12, table P2-21 for breaker kits and accessories (2) Part # for Interior only (3) Refer to Pg 4 for Main breaker selection (4) Refer to Pg 5 for Branch circuit breaker selection
(5) Refer to Pg 12, table P2-20 for box and trim details (6) For more number of circuits, contact local Siemens representative before ordering
Panel Modifications
• Main Bus
Standard main bus is temperature rated tin-plated aluminum.
Bus options are 750 A/Si aluminum, tin-plated temperature
rated copper tin-plated standard – silver optional. 1000 A/Si
copper tin-plated standard – silver optional. Includes copper
neutral cross bar. For copper neutral branch lugs, see
miscellaneous.
• Split bus adds 6” to unit space*
Compression lug for MLO*
Compression lugs on main breaker (may require
extra width or length on enclosure).
*
Contactor mains or submain*
Asco 920 through 225 amps. Adds 12” unit space as main,
15” unit space as submain.
*
Asco 911 through 150 amps. Adds 21” unit space.
*
• Siemens LEN through 30 amps. Adds 12” unit space.
*
Makes box 10" deep.
Control power transformers (contact engineering for extra*
gutter requirements)
Branch and main breaker accessories
• Handle blocks
• Handle locks
• Aux. Contacts 1
• UVR 1
• Feed-thru lugs
• 200% neutral
• Copper lugs, mechanical
• Bus mounted TVSS
• Service entrance labeled
1Accessories on 1" pole breakers (BL, BQD, ED) will take unit space.
*Contact local Siemens representative for any options & modifications.
• Grounding of panelboards
Ground bars are shipped with the panel interior factory
mounted.
• Non-insulated equipment ground bar – standard
• Copper non-insulated ground bar
• Aluminum insulated equipment ground bar
• Copper insulated equipment ground bar
Shunt trip on main or branch
BL, BLH, HBL, ED2, ED4, HED4, HED6, HHED6 uses 1”
unit space for shunt trip. All may be used on mains
or subfeeds.
Remote control switches – mounted in a 23” enclosure
to be cable connected to the panel.
Time clocks – mounted in a 23” enclosure to be cable
connected to the panel. Sangamo, tork or paragon time
clock can be supplied and mounted in panelboard cabinet.
QJ2, QJ2-H, QJH2, HQJ2H, ED2, ED4, ED6, HED4, HED6,
FXD6, HFD6, JXD6, JD6, HJD6, HJXD6
P2 Panelboards
Modifications*
Siemens P2 Panelboards – Selection & Application Guide 7
P2 Panel Options
Enclosures
• Extra gutter to sides or ends of the can
• 24" wide boxes
• Hinged trims*
• Door-in-door trims*
• Screw to the box trims*
Trim mounted devices (Devices mounted and wired
to the trim should also have hinged trim specified)
• Pilot lights
• Toggle switches
• Push buttons
• Painted boxes
• Custom colors
• Increase gauge trims and boxes*
• Stainless steel trims and boxes, Type 1
*
• Aluminum trims and boxes, Type 1
*
• NEMA 3R/12 enclosures
• NEMA 4 enclosures
• NEMA 4X enclosures
• Special keyed locks*
• Gasketing trim to box
• Panel skirts
Table P2-12 – Box Size Additions (In.) For Optional Features
Main Lugs Main Breakers
125A 250A 400A 600A 125A 125A 125A 225A 250A 250A 400A 400A 600A 600A
Horiz. Horiz. Vert. Vert. Vert. Vert. JD CJD LD CLD
Options BL,BQD,ED CED ED QJ FD CFD
200 Neutral 0 0 6 (all) 6 (all) 0 0 0 6 6 0 0 0 0 0
(lug type)
Std. Lugs 00 0 00 0 0 6 60 0 0 0 0
(100% Neut. PNL)
CU Lugs (100% 66 6 06 6 0 6 60 0 0 0 0
Neut. PNL)
Comp Lugs 66 6 66 6 0 6 60 0 0 0 0
(100% Neut. PNL)
Feed-thru
Standard Lugs 6 6 12 12 6 6 6 6 6 6 12 12 12 12
Feed-thru Cu Lugs 6 6 12 N/A 6 6 6 6 6 6 12 12 12 N/A
Feed-thru
Comp Lugs 6 12 12 N/A 6 6 6 6 12 12 12 12 12 N/A
Subfeed Standard
Lugs 0 6 6N/A —— ——
Split Bus 6 6 6 6 6 6 6 6 6 6 6 6 6 6
(1) FD Subfeed N/A 12 12 12 N/A N/A N/A N/A 12 12 12 12 12 12
(Horizontal Mtg.)
(2) FD Subfeed N/A 24 24 24 N/A N/A N/A N/A 24 24 24 24 24 24
(Vertical Mtg.)
TVSS 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Split bus is paired with feed-thru lugs by default. Feed-thru lugs are to feed the section after the split. NOTE: N/A = OPTION NOT AVAILABLE
*Contact local Siemens representative before any modification.
P2 Panelboards
Siemens P2 Panelboards – Selection & Application Guide
Modifications*
8
Style Amp Rating Breaker Type Compression Connectors Box Height Addition
125 N/A (1)#6 - 350 Kcmil Al/Cu 6
250 N/A (1)#6 - 350 Kcmil Al/Cu 6
MLO 400 N/A (1) 400 - 600 Kcmil Cu or 6
(2)#6 - 350 Kcmil Al/Cu
600 N/A (2)#6 - 350 Kcmil Cu or Cu/Al or 6
400 - 600 Kcmil Al/Cu
100 ED4, ED6, HED4 (1)#14-2/0 AWG Cu or Al Box must go to 24” wide on CED6 breaker only
CED6 Add 6” to box height for NØ
QJ2, QJH2, QJ2H (1)#6 AWG - 350 Kcmil Cu or Al Box must go to 24” wide
225 FXD6, HFD6, CFD6 (1)#6 AWG - 350 Kcmil Cu or Al Box must go to 24” wide for all breakers
Requires an additional 6.0” box height
Main Breaker JD6, JXD6, HJD6, (2)#1/0 AWG - 500 Kcmil Cu or Al 9
400 CJD6, SJD6, SHJD6,
SCJD6
LD6, LXD6, HLD6, (2)#2/0 AWG - 500 Kcmil Cu or Al 6
600 CJD6, SLD6, SHLD6,
SCLD6
Compression Lugs
Table P2-13 – Lugs
Style Amp Rating Breaker Type Compression Connectors Box Height Addition
MLO 400 N/A (1) 250 - 750 Kcmil or 6
(2)#3/0 AWG - 250 Kcmil Cu or Al
JD6, JXD6, HJD6,
Main Breaker 400 CJD6, SJD6, SHJD6, (1)#4/0 AWG - 750 Kcmil Cu or Al 6
SCJD6
Table P2-14 – Alternate Lugs*
P2 Panelboards
Connector Modifications
Siemens P2 Panelboards – Selection & Application Guide 9
*Contact local Siemens representative for any modifications.
Enclosure Modifications
Remote Switch Modifications
Box Height Enclosure Size
Inches H W D
26 30 24 8
32 36 24 8
38 42 30 8
44 48 36 8
50 60 36 8
56 60 36 8
62 66 36 8
68 72 36 8
74 78 36 8
80 84 36 8
NEMA-4 For Type P2*
Water Tight, Dust Tight, Steel Enclosure
Table P2-18 – Application For Remote Switch*
Switch Type Modification
920 Adds 12” to unit space
911 ≤ 225A adds 21” unit space >225 ≤400 Amps add 10” to width and 8” DP
minimum and 24” to height
30A adds 15” to unit space
LEN >30A 100 adds 12” to unit space
7.7 Dp. Box min.
100 A ≤ 200 adds 12” to unit space and 10” DP. min.
Table P2-19 – Remote Control
Switch Modification*
Description
Auxiliary Contacts (Mounted Not Wired) Ea.
2-Wire Control
Table P2-17 – Control Power*
Transformer
Size VA
0,1 50
275
3 150
4 250
Table P2-15
NEMA-4X For Type P2*
Water Tight, Dust Tight and Corrosion Resistant
Enclosure - Stainless Steel Enclosure - Fiberglass
and Steel with Epoxy Coating Size (inches)
Box Height
Inches H W D H D W
26 30 24 8 30 24 8
32 36 24 8 36 24 8
38 48 36 8 48 36 12
44 48 36 8 48 36 12
50 60 36 12 60 36 12
56 60 36 12 60 36 12
62 66 36 8 72 36 8
68 72 36 8 72 36 8
74 78 36 8 84 36 8
80 84 36 8 84 36 8
Table P2-16
P2 Panelboards
Siemens P2 Panelboards – Selection & Application Guide
Connector Modifications
10
*Contact local Siemens representative for any modifications.
Type 1 Box
Box is symmetrical
Type 3R/12 Box
1Dimensions are interior of the box. Add 5/8” to width for
absolute dimension. Add 1/8” to height for absolute dimension.
Dimensions shown in inches and millimeters [ ].
P2 Panelboards
Dimensions
Siemens P2 Panelboards – Selection & Application Guide
11
Table P2-20 – Standard Enclosures
Table P2-21 – Breaker Kits and Accessories (1)
Kit No. Description Contents
BBKB32AT BL/BQD 6-pole 3” branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware (Al/Tin)
BBKED32AT ED 6-pole 3” branch breaker kit Kit contains breaker support, inter-phase barriers, (3) A/C connectors, (1) B connector, hardware (Al/Tin)
BBKQ1AT QJ branch breaker kit for 2 and Kit to contain all connectors and cover plates necessary to mount both 2 and 3-pole breakers (Al/Tin)
3-pole single mount
DFK1 BL, BQD, ED deadfront kit for Center strips 3”, 6”, 9,” 15,” 21” plus mounting hardware
1” pole breakers
DFFP3 Deadfront filler 3” 3” empty space filler and hardware
DFFP6 Deadfront filler 6” 6” empty space filler and hardware
BNK2 Branch neutral (P2) Three tier lug with mounting hardware to increase neutral capacity
P2BK1 P2 250A max. Bonding Kit Bonding strap and hardware
P2BK2 P2 400A max. Bonding Kit Bonding strap and hardware
P2BK3 P2 600A max. Bonding Kit Bonding strap and hardware
BBKB32CS BL/BQD 6-pole 3” branch breaker kit Kit contains top barrier, (3) A/C connectors, (1) B connector, hardware (Cu/Silver)
BBKED32CS ED 6-pole 3” branch breaker kit Kit contains breaker support, inter-phase barriers, (3) A/C connectors, (1) B connector, hardware (Cu/Silver)
BBKQ1CS QJ branch breaker kit for 2 and Kit to contain all connectors and cover plates necessary to mount both 2 and 3-pole breakers (Cu/Silver)
3-pole single mount
Options for Type 1 & 2 Tubs
Add suffix "K" for enclosure c/w tub end wall with knockouts
Add suffix "KN" for enclosure c/w tub end wall with knockouts and gasketed
Add suffix "N" for enclosure gasketed
Add suffix "P" for enclosure painted std grey
Add suffix "PK" for enclosure painted std grey c/w tub end wall with knockouts
Add suffix "PKN" for enclosure painted std grey c/w tub end wall with knockouts and gasketed
Add suffix "PN" for enclosure painted std grey and gasketed
Add suffix "M" for metal card holder
Hinged trim - Replace "B" suffiz with "H"
Door-in-door - Replace "B" suffix with "D"
Metal card holder – Add “M” suffix
Option For 24” Wide Enclosures with Equal Gutter on Both Sides
24” wide with equal gutter on both sides - Add “24” as prefix
(1) For Silicon free enclosure, contact local Siemens representative.
Catalogue Number
Box Type 1 Type 2 Type 3R/12 (1)
Height Standard Trim Standard Trim
Complete Enclosure
Inches Box Surface Flush Box Surface With
Hinged Cover
26 B26 S26B F26B DSB52026 S26B WP26
32 B32 S32B F32B DSB52032 S32B WP32
38 B38 S38B F38B DSB52038 S38B WP38
44 B44 S44B F44B DSB52044 S44B WP44
50 B50 S50B F50B DSB52050 S50B WP50
56 B56 S56B F56B DSB52056 S56B WP56
62 B62 S62B F62B DSB52062 S62B WP62
68 B68 S68B F68B DSB52068 S68B WP68
74 B74 S74B F74B DSB52074 S74B WP74
P2 Panelboards
Siemens P2 Panelboards – Selection & Application Guide
Kits and Accessories
12
(1) For CEDG branch breaker kit, contact local Siemens representative
SIEMENS IN CANADA Siemens is one of the largest and most diversified
companies in the world, providing innovations in areas such as health care, information
& communications, energy & power, industry & automation, transportation and lighting.
In Canada, Siemens is headquartered in Mississauga, Ontario, and has 73 offices and
nine manufacturing facilities across the country. Locations span from coast to coast,
staffed by more than 6,200 employees.
IN HEALTH CARE, we provide complete integrated solutions, from diagnostic
imaging equipment, telemedicine solutions, clinical networking systems and patient
monitoring/life support systems to consultative services and staff training. These offerings
not only improve patient care but also increase administrative, financial and clinical
efficiencies and streamline workflow processes. As the world’s largest manufacturer of
hearing instruments, Siemens offers assistive listening devices that improve quality of
life for the hard of hearing.
IN INFORMATION & COMMUNICATIONS, we continue to focus on an
ever-widening range of network technologies including the engineering and integration
of next generation voice, data, standard and wireless applications. In the Canadian
cellular market, Siemens is breaking new ground in establishing GSM services with a
strong GSM/GPRS portfolio. We offer complete solutions for network access, optical
switching and core routing technologies and we are a leading provider of single-source
IT consulting solutions and management services for supply chain, enterprise resource,
business information and customer relationship.
IN ENERGY & POWER, we supply reliable power solutions, from generation
and distribution to control and automation applications. We provide the most responsive
sources of solutions to improve the competitiveness and profitability of our customers’
operating plants.
IN INDUSTRY & AUTOMATION, we offer integrated automation solutions
to increase productivity at all levels of industry, from component-level support and simple
process control to designing, building, commissioning, servicing and maintaining
integrated plant systems. To help our customers manage their facilities more efficiently,
we provide building maintenance services and control systems from fire alarms to climate
control. We also offer a full range of postal automation systems and support services.
IN TRANSPORTATION, Siemens offers a wide range of rail vehicles, from
complete transportation systems and people movers to rolling stock for light rail, heavy
rail and subways. In addition, we supply all major transportation system elements, such
as train control, systems electrification and systems maintenance. For the automotive
industry, we have developed a new technology involving electronically controlling
engine acoustics via the air intake system.
IN LIGHTING, through OSRAM SYLVANIA LTD., we are a leader in the Canadian
lighting market, dedicated to setting new market standards in commercial & industrial,
consumer, automotive, specialty and lighting services.
IN FINANCING, we provide a full range of customized financial services for the
acquisition of capital equipment and services. We offer complete financial solutions
including: loans; leases; project funding; financial expertise; technology leases and
customized applications.
2004
Customer Interaction Centre
Tel: (888) 303-3353
Siemens Canada Limited
Automation & Drives
1550 Appleby Line, Burlington, ON L7L 6X7
For further innovations visit www.siemens.ca
P2 PANELBOARDS SELECTION & APPLICATION GUIDE
INDUSTRY AND AUTOMATION
1.0_04/04_A&D-1305
Your local contact is:

Navigation menu