Volume 7 Tab 1 110681 Catalog
2014-05-16
: Pdf 110681-Catalog 1 110681-Catalog_1 046135 Batch3 unilog
Open the PDF directly: View PDF
.
Page Count: 340
| Download | |
| Open PDF In Browser | View PDF |
www.sylvania.com
Note:
OSRAM SYLVANIA LTD./LTÉE
2001 Drew Road
Mississauga, Ontario L5S 1S4
OEM/Special Markets
Phone: 800-762-7191
Fax:
800-762-7192
National Accounts
Phone: 800-562-4671
Fax:
800-562-4674
Industrial Commercial
Phone: 800-255-5042
Fax:
800-255-5043
Consumer Products
Phone: 800-842-7010
Fax:
800-842-7011
Display/Optic
Phone: 888-677-2627
Fax:
800-762-7192
OEM/Special Markets
Phone: 800-265-2852
Fax:
800-667-6772
Industrial Commercial
Phone: 800-263-2852
Fax:
800-667-6772
Consumer Markets
Phone: 800-720-2852
Fax:
800-667-6772
Display/Optic
Phone: 800-265-2852
Fax:
800-667-6772
SYLVANIA LIGHTING
SERVICES:
Phone: 800-663-4268
Fax:
866-239-1278
SYLVANIA LIGHTING
SERVICES:
Phone: 800-323-0572
Fax:
978-750-2784
CAPSYLITE, CAPSYLITE IR, CURVALUME, DAYLIGHT, DAYLIGHT PLUS, DESIGNER, DESIGN 50, DESIGNER PLUS, Dot-It, DURA-ONE, ECO, ECOLOGIC, elogic, EXCEL-LINE,
Fixtureside Assistance, GRO-LUX, HALOGEN PLUS, HALOGEN XTRA, HELIOS, ICETRON, LINESTRA, LUMALUX, LUMALUX PLUS, METALARC, METALARC PRO-TECH,
OCTRON, PENTRON, POWERBALL, POWERSENSE, PROSTART, QUICKSENSE, QUICK 60+, RHINOCOAT, SAFELINE, SPOT-GRO, SUNSTICK, SUPERSAVER, SUPERSAVER
PLUS, SYLVANIA, The System Solution and Squiggle Logo, TRU-AIM, TRU-AIM BRILLIANT, TRU-AIM TITAN, UNALUX, XP and XPS are trademarks or registered
trademarks of OSRAM SYLVANIA.
Printed on recycled paper. 1/08
Mexico
OSRAM MEXICO
Headquarters
TuItitlan/Edo DeMexico
011-52-55-58-99-18-50
www.sylvania.com
OSRAM SYLVANIA
National Customer
Service and Sales Center
18725 N. Union Street
Westfield, IN 46074
Lamp and Ballast Catalog
© 2008 OSRAM SYLVANIA
Canada
OSRAM SYLVANIA LTD./LTÉE
Headquarters
2001 Drew Road
Mississauga, Ontario L5S 1S4
1-800-LIGHTBULB
www.sylvania.com
For Orders and
General Information
in Canada:
Lamp and Ballast Catalog
United States
OSRAM SYLVANIA
Headquarters
100 Endicott Street
Danvers, MA 01923 USA
1-800-LIGHTBULB
www.sylvania.com
For Orders and
General Information
in the United States:
Certain photography
At the time of printing, new wattages of SYLVANIA Incandescent A19, Medium Screw
Base, 120 Volt and 130 Volt lamps with Soft White, Inside Frost and Clear finishes have
been developed to meet new State of California standards effective January 1, 2008
but are not yet listed in this catalog. For more information on the legislation and these
new lamps, please visit www.sylvania.com. Click on State Product Regulations.
AluPAR, BELLAPHOT, DRAGON, DULUX, HBO, HLX, HMD, HMI, HMP, HPR, HQI, HSD, HSR, HTI, HXP, SharXS, GLOBAL CARE, LINEX, MINISTAR, OPTOTRONIC, OStar,
OSRAM, P-VIP, QUICKTRONIC, SUPERPHOT, STUDIOLINE, VIP, XBO, XENOPHOT, XERADEX and Xstage are trademarks or registered trademarks of OSRAM GmbH.
All other trademarks contained herein not owned by OSRAM SYLVANIA or its subsidiaries, are the property of their respective owners.
CATALOG08
L&B_Cover_Lot A.indd
1
1/3/08
6:37:52 AM
8THS
OSRAM SYLVANIA
SEE THE WORLD IN A NEW LIGHT
For more than 100 years, OSRAM SYLVANIA has been a leader
in the development of innovative lighting. This catalog provides
specifications on over 3000 SYLVANIA and OSRAM branded
products for a variety of lighting applications, each one designed
and manufactured to the highest possible standards.
A Lighting Industry Leader
With over 14,000 employees, OSRAM SYLVANIA is one of the leading
lighting systems companies in North America. We are the North
American business unit of OSRAM GmbH, one of the world’s
largest lighting manufacturers. OSRAM SYLVANIA is a member
of the SIEMENS worldwide family of companies, which employs
over 440,000 people in over 190 countries.
Meeting Customer Expectations
OSRAM SYLVANIA makes ongoing investments in new and aggressive
business practices. With the Total Cycle Time program, we have
turned time into a strategic business ally. Our SAP program unites
the entire organization with a sophisticated information system that
helps serve our customers faster and more efficiently. Our ISO 9000,
ISO 14001 and QS 9000 certifications show our achievements in delivering the highest quality lighting products.
Lighting the World
OSRAM SYLVANIA, together with OSRAM GmbH, is the largest supplier
of electronic lighting systems in the world. As leaders in fluorescent,
halogen and metal halide technologies, the companies hold numerous international lighting patents and have an extensive engineering
and manufacturing network. OSRAM GmbH and OSRAM SYLVANIA literally bring light to the world.
Lamp Disposal Labeling
For all mercury-containing lamps manufactured after November 30,
2003, OSRAM SYLVANIA has incorporated the symbol “Hg” into the
lamp etch, except for products where size or thermal constraints
prevent etching in this manner. This action is part of the National
Electrical Manufacturers Association (NEMA) lamp labeling initiative,
the purpose of which is to guide users of lighting products—via internet or telephone—to appropriate contacts regarding disposal of
spent mercury-containing lamps (fluorescent, compact fluorescent,
and most HID).
Disposal labels appear on the inner-most packages of mercury-containing lamps, the outer cartons, or both. For Display-Optic and some
other specialized lamp types, labeling is included in the stuffer. This
labeling format complies with the requirements of existing states’
legislation and has been designed to be universally applicable to all
US States.
Hg LAMP CONTAINS MERCURY
Manage in Accordance with Disposal Laws
See: www.lamprecycle.org or 1-866-666-6850
Information in this catalog is subject to change at any time without prior notice.
_____
1
_____
T2
_____
3
_____
T4
_____
T5
_____
T6
_____
7
_____
T8 ➤
_____
9
_____
B10 ➤
_____
11
_____
T12 ➤
_____
13
_____
PAR14
_____
15
MR16 ➤ _____
_____
G16 1/2
_____
A17 ➤
_____
ET18
_____
A19 ➤
PAR20 ➤ _____
_____
A21
_____
22
_____
23
________________
_____
G25 ➤
_____
26
_____
27
_____
BT28
_____
29
PAR30 ➤ _____
_____
31
________________
_____
33
_____
34
_____
35
_____
36
_____
BT37
PAR38 ➤ _____
_____
39
R40, G40 ➤ _____
_____
41
_____
42
_____
43
_____
44
_____
45
PAR46 ➤ _____
_____
47
________________
_____
49
_____
50
_____
51
PAR52 ➤ _____
_____
53
_____
54
_____
55
BT56/PAR56 _____
_____
57
_____
58
_____
59
_____
60
_____
61
_____
62
_____
63
PAR64 ➤ _____
_____
65
_____
66
_____
67
_____
68
_____
69
_____
70
_____
71
________________
_____
73
_____
74
_____
75
_____
76
_____
77
_____
78
_____
79
INCHES
1/4
1/2
3/4
1
2
3
4
5
6
7
8
9
i
L&B_Cover_Lot A.indd
2
1/3/08
6:38:02 AM
8THS
OSRAM SYLVANIA
SEE THE WORLD IN A NEW LIGHT
For more than 100 years, OSRAM SYLVANIA has been a leader
in the development of innovative lighting. This catalog provides
specifications on over 3000 SYLVANIA and OSRAM branded
products for a variety of lighting applications, each one designed
and manufactured to the highest possible standards.
A Lighting Industry Leader
With over 14,000 employees, OSRAM SYLVANIA is one of the leading
lighting systems companies in North America. We are the North
American business unit of OSRAM GmbH, one of the world’s
largest lighting manufacturers. OSRAM SYLVANIA is a member
of the SIEMENS worldwide family of companies, which employs
over 440,000 people in over 190 countries.
Meeting Customer Expectations
OSRAM SYLVANIA makes ongoing investments in new and aggressive
business practices. With the Total Cycle Time program, we have
turned time into a strategic business ally. Our SAP program unites
the entire organization with a sophisticated information system that
helps serve our customers faster and more efficiently. Our ISO 9000,
ISO 14001 and QS 9000 certifications show our achievements in delivering the highest quality lighting products.
Lighting the World
OSRAM SYLVANIA, together with OSRAM GmbH, is the largest supplier
of electronic lighting systems in the world. As leaders in fluorescent,
halogen and metal halide technologies, the companies hold numerous international lighting patents and have an extensive engineering
and manufacturing network. OSRAM GmbH and OSRAM SYLVANIA literally bring light to the world.
Lamp Disposal Labeling
For all mercury-containing lamps manufactured after November 30,
2003, OSRAM SYLVANIA has incorporated the symbol “Hg” into the
lamp etch, except for products where size or thermal constraints
prevent etching in this manner. This action is part of the National
Electrical Manufacturers Association (NEMA) lamp labeling initiative,
the purpose of which is to guide users of lighting products—via internet or telephone—to appropriate contacts regarding disposal of
spent mercury-containing lamps (fluorescent, compact fluorescent,
and most HID).
Disposal labels appear on the inner-most packages of mercury-containing lamps, the outer cartons, or both. For Display-Optic and some
other specialized lamp types, labeling is included in the stuffer. This
labeling format complies with the requirements of existing states’
legislation and has been designed to be universally applicable to all
US States.
Hg LAMP CONTAINS MERCURY
Manage in Accordance with Disposal Laws
See: www.lamprecycle.org or 1-866-666-6850
Information in this catalog is subject to change at any time without prior notice.
_____
1
_____
T2
_____
3
_____
T4
_____
T5
_____
T6
_____
7
_____
T8 ➤
_____
9
_____
B10 ➤
_____
11
_____
T12 ➤
_____
13
_____
PAR14
_____
15
MR16 ➤ _____
_____
G16 1/2
_____
A17 ➤
_____
ET18
_____
A19 ➤
PAR20 ➤ _____
_____
A21
_____
22
_____
23
________________
_____
G25 ➤
_____
26
_____
27
_____
BT28
_____
29
PAR30 ➤ _____
_____
31
________________
_____
33
_____
34
_____
35
_____
36
_____
BT37
PAR38 ➤ _____
_____
39
R40, G40 ➤ _____
_____
41
_____
42
_____
43
_____
44
_____
45
PAR46 ➤ _____
_____
47
________________
_____
49
_____
50
_____
51
PAR52 ➤ _____
_____
53
_____
54
_____
55
BT56/PAR56 _____
_____
57
_____
58
_____
59
_____
60
_____
61
_____
62
_____
63
PAR64 ➤ _____
_____
65
_____
66
_____
67
_____
68
_____
69
_____
70
_____
71
________________
_____
73
_____
74
_____
75
_____
76
_____
77
_____
78
_____
79
INCHES
1/4
1/2
3/4
1
2
3
4
5
6
7
8
9
i
L&B_Cover_Lot A.indd
2
1/3/08
6:38:02 AM
Table of Contents
Sustainability
III
SYLVANIA ECOLOGIC®
IV
Lamp Recycling
Energy and the Cost of Lighting
IESNA Progress Report
Glossary of Terms
Incandescent Lamps
V
VI
VII
IX–XII
1
Tungsten Halogen Lamps
41
Miniature Lamps
72
High Intensity Discharge (HID) Lamps
75
Compact Fluorescent Lamps
107
Fluorescent Lamps
129
Ballasts and LED Power Supplies
171
Display/Optic Lamps
207
LED Systems
297
Consumer Luminaires
314
LED Retrofit Lamps
315
Warranties
316
Index
322
Important Notice
The OSRAM SYLVANIA Test and Measurement Laboratory is a participant in the Energy Efficient Lighting (EEL)
Program of the National Voluntary Laboratory Accreditation Program (NVLAP-NIST) and is accredited for testing
of lighting products according to the guidelines for the EEL Program. OSRAM SYLVANIA lamp and ballast
measurements are conducted under laboratory conditions utilizing American National Standards Institute (ANSI),
Canadian Standards Association (CSA), Commission Internationale de l’Eclairage (CIE), and Illuminating Engineering
Society of North America (IESNA) standards and practices. The OSRAM SYLVANIA Electronic Component and
Systems Development Group participate in the Underwriters Laboratories Inc. Client Test Data Program. Ballast
designs are tested for conformance to Underwriters Laboratory (UL) safety standards using practices audited,
assessed and approved by UL. Actual lamp and ballast performance may vary depending on application and
environment (i.e. ambient temperature, input voltage, ballast type, etc.)
The data and suggested applications contained in this catalog, as well as any additional information our
representatives may be able to furnish, are for general information only and are not intended and should not be
taken as representations or warranties as to the suitability of a lamp for any particular application or use in any
particular equipment, nor are our representatives authorized to make any such representations or give any such
warranties. Applications and conditions of use are many and varied and beyond our control. We do not have the
same degree of knowledge that the purchaser has with respect to the design of his equipment and the conditions
of its use. Therefore, it is up to the purchaser to make his own determination as to the suitability of a lamp for his
intended application or use and to assume responsibility for that determination.
OSRAM SYLVANIA claims to supply the best possible products at all times. For this reason, OSRAM SYLVANIA
reserves the right to make changes in its products when it believes such changes will improve its products.
OSRAM SYLVANIA designs and manufactures lamps and ballasts to meet American National Standard Institutes
(ANSI) and/or IEC (International Electrotechnical Commission) standards of construction and performance through
Total Quality Manufacturing (TQM) practices where applicable. In addition, ballasts are designed and manufactured
to meet Underwriters Laboratory (UL) and Canadian Standards Association (CSA) safety standards as necessary.
Ratings may change as a result of changes made to remain compliant with modified or updated standards. OSRAM
SYLVANIA will release new or updated technical bulletins when appropriate. All product data presented in this
catalog supersedes all data published before 10/1/07.
The specifications and information shown in this catalog are believed to be accurate. Although OSRAM SYLVANIA
believes this information to be correct, no warranty is made or implied as to the accuracy of this information and
OSRAM SYLVANIA does not accept or assume responsibility of liability for errors, changes, omissions, or for harm
resulting therefrom.
In accordance with our established policy to consistently improve our products, the specifications
contained herein are subject to change without notice.
Many OSRAM SYLVANIA products listed in this catalog qualify under the North American Free Trade Agreement
(NAFTA) as manufactured in Canada, the United States of America or Mexico.
ii
Luminance Contrast The relationship between
PAR Lamps Pressed aluminized reflector lamp,
Safety Ballasts should be installed and operated
the luminances of an object and its immediate
background.
with the outer bulb formed from two pressed glass
parts that are fused or sealed together. PAR lamps
may be incandescent, halogen, or HID types.
in compliance with the National Electric Code
(NEC), Underwriters Laboratories Inc. (UL) requirements, and all applicable codes and regulations.
Since it is possible to come in contact with potentially hazardous voltages, only qualified personnel
should perform ballast installation. All installation,
inspection, and maintenance of lighting fixtures
should be done with the power to the fixture
turned off.
Luminance Ratio The ratio between the
luminances of any two areas in the visual field.
Lux (lx) A unit of illuminance equal to 1 lumen
per square meter.
Maximum Case Temperature All OSRAM
SYLVANIA electronic ballasts have a maximum
allowable case temperature of 70°C and 90°C
for magnetic fluorescent ballasts. Applications
in which the case temperature exceeds this
maximum void all warranties.
Parallel vs. Series Wiring configurations for ballasts. Ballasts with parallel lamp circuitry have the
benefit of companion lamps remaining lit, even if
one of the lamps operated by the ballast should
fail. Systems with series lamp wiring (magnetic
ballasts and many rapid start electronic types)
result in all lamps operated on the ballast going
out if one should fail.
length of a lamp, from top of bulb to bottom
of base.
Photo-Optic Specialty Lamps Photo-Optic
specialty lamps employ a variety of technologies
to meet the very precise levels of performance
required by the entertainment industry, science,
medical and other high-tech fields.
Mean Lumens Lumen output of a light source
Power The rate at which energy is taken from
after the source has been used. Mean lumen
values for fluorescent and HID lamps are typically
measured at 40% of their rated lives. Most high
pressure sodium and mercury lamps are measured at 50% of their rated lives. All measurements
are made on ANSI reference ballasts. Mean
lumens are not typically measured for incandescent and tungsten halogen lamps.
an electrical system or dissipated by a load,
expressed in watts (W); power that is generated by
a utility is typically expressed in volt-amperes (VA).
Mean Spherical Candela (MSCD) The average
value of the luminous intensity of a light source
in all directions. To convert MSCD to Lumens,
multiply by 4π (12.57).
Preheat A class of fluorescents requiring a starter,
which allows the lamp and filaments to be properly
heated before allowing the ballast to supply the
correct current flow.
Mean Time Between Failures (MTBF)
Product Number (See NAED.)
Maximum Overall Length (MOL) The total
A calculation of ballast life based on thermal
conditions, component values, and circuit
characteristics used to develop relative predictions of ballast life. OSRAM SYLVANIA uses
methodology that typically provides a 1:10 actual
life prediction based on MTBF calculations.
NAED A five-digit number used to identify a specific OSRAM SYLVANIA lamp. This NAED number
in this catalog is labeled Product Number and
should be used when ordering OSRAM SYLVANIA
products. NAED is the abbreviation for National
Association of Electrical Distributors.
Nanometer (nm) A unit of length equal to 10-9
meters; commonly used as a unit of wavelength.
Nominal Watts Wattage used to describe a
lamp. Also see Power and Watt.
OFR Abbreviation for “ozone free” technology.
Lamps with the designation OFR do not generate
ozone during operation.
Operating Position Some lamps are specified/
designed to be operated in certain positions, i.e.,
horizontal or base up.
Ordering Abbreviation Provides a shorthand
description of the lamp, using a unique code
which can be used when ordering a lamp if the
Product Number is not known. An example would
be: CF15EL/R30/830/MED, which translates to a
15-watt Soft White DULUX® EL reflector electronic
self-ballasted compact fluorescent lamp with an
R30 reflector, 82CRI, 3000K color temperature
and a medium screw base.
Power Factor A measure of the effectiveness
with which an electrical device converts voltamperes to watts; devices with power factors
(>0.90) are “high power factor” devices.
Programmed Rapid Start (PS) A method of
starting fluorescent lamps where cathode heat is
applied prior to lamp ignition, then removed or
reduced once the lamp has ignited. PROStart®
ballasts maximize the number of lamp starting
cycles while maintaining energy efficiency. This is
the preferred mode of lamp starting for applications with occupancy sensors and several on/off
cycles per day. Additionally, the lamps will strike
reliably in cold conditions down to 0°F.
Rapid Start (RS) Rapid start ballasts apply
a low filament voltage to preheat the cathodes.
Simultaneously, a starting voltage (lower than that
used in instant start) is also applied to strike the
arc. When the cathodes are hot enough, the lamp
will strike. The filament voltage continues to be
applied throughout the operation of the lamp.
Rapid start ballasts appear to have a slight turn on
delay compared to instant start. They will typically
not be able to start lamps reliably under 50°F.
Reference Ballast A ballast specially constructed to have certain prescribed characteristics for
use in testing electric-discharge lamps and other
ballasts. Reference ballasts are typically defined by
ANSI.
Reflector A device used to redirect the light by
the process of reflection. Photo-Optic reflector
lamps utilize ellipsoidal (converging light rays) or
parabolic (collimating light rays) reflectors. Dichroic
coated reflectors are designed to reflect visible light
and pass through unwanted infrared wavelengths.
Resistance (R) A measure of resistance to flow
of current, expressed in ohms (Ω).
xi
Shielding A general term to include all devices
used to block, diffuse or redirect light rays, including baffles, louvers, shades, diffusers and lenses.
Single-Ended Lamps having a single lamp base
or point of electrical connection.
Spectral Power Distribution (SPD)
A curve illustrating the distribution of radiant power
produced by the lamp, at each wavelength across
the spectrum.
Spotlight A luminaire using halogen/incandescent
or a high intensity discharge (HID) lamp that produces a narrow beam angle designed to illuminate
a specifically defined area. It can also be called a
reflector lamp.
TCLP Test (Toxicity Characteristic Leaching
Procedure) Federal EPA regulations (RCRA of
1990) have defined a TCLP test to determine
whether wastes are to be treated as hazardous
or non-hazardous.
Total Harmonic Distortion (THD) A measure
of the distortion of an electrical wave form.
Excessive THD (defined by ANSI as greater than
32%) may cause adverse effects to the electrical
system. <20% THD ballasts are fine for most
applications. However, in buildings with neutral
problems caused by high THD loads such as
computers, printers, DC supplies, etc., the <10%
THD products can help reduce the overall % of
Total Harmonic Distortion.
Transient Protection OSRAM SYLVANIA ballasts meet ANSI 62.41 Category A. This helps
ensure immunity to electrical disturbances such as
power line transients, and temporary line voltage
dropouts, surges and sags.
Trigger Start A circuit used to eliminate the
starter and start the preheat lamp almost instantly.
In this circuit each electrode is connected to a
separate winding in the ballast so that the electrode is continuously heated.
Tungsten Halogen Cycle A regenerative cycle
of tungsten and halogen atoms, which, when incorporated into the design of halogen light sources,
prevents blackening of the lamp envelope during life.
Voltage (V) A measure of electrical potential,
expressed in volts (V). Voltage is the “force” that
pushes electrical current through a conductor.
Watt (W) A unit of electrical power equal to 1
joule per second. Lamps are rated in watts to indicate power consumption. Also see Nominal watts.
Wavelength (λ) Distance between two successive points of a periodic wave; the wavelengths of
light are typically expressed in nanometers (nm),
or billionths of a meter.
Working Distance (See Focal Distance.)
Sustainability in Action
Meeting our needs today without compromising the resources future generations will need — touches everything we
do as a company. It’s all about reducing environmental impact, a commitment that goes beyond our products to include
how the products are manufactured, how they are used and how they are distributed and disposed. It even extends to
the design of “greener” buildings.
Sustainability is everybody’s business.
Global Care:
When we can do more with less, everyone wins.
Businesses need to find ways to grow without
adding to our environmental footprint — and the
good news is, we’re making steady progress.
Advanced technologies are helping us to be
more efficient. We’re using less energy and
fewer resources, and generating less waste.
Global Care represents our commitment to
corporate responsibility. This initiative is designed
to drive positive results to the triple bottom line
addressing social, economic and environmental
needs. Furthermore, we are dedicated to meeting
our customers’ lighting needs with a sustainable
approach to product design, development,
manufacturing and distribution.
At a personal, corporate or national level, lighting
plays an important role in any sustainability strategy.
Whether you’re interested in lowering your energy
consumption, avoiding unnecessary maintenance,
identifying options for lamp and ballast recycling,
or finding products with
fewer hazardous materials,
OSRAM SYLVANIA can help.
We integrate environmental responsibility into
every area of our company. As a result, we are
using fewer natural resources, saving energy
for our customers, reducing
power plant emissions, and
recycling lamps and other
materials to avoid millions of
pounds of waste in landfills.
™
iii
ECOLOGIC® products are the industry’s
most comprehensive line of environmentally preferable lighting solutions.
Our lamps designated as ECOLOGIC pass the U.S. EPA’s
Toxic Characteristic Leaching Procedure (TCLP) test for
hazardous waste determination. Products meeting the TCLP
test may be declared “universal waste” in many states,
easing the administrative, storage and transportation
burdens for these products. (Check your state and local
governments for the most accurate regulations.)
With more than 800 products meeting our strict ECOLOGIC
guidelines and bearing the distinct “ECO®” designation,
we offer more environmentally preferable lamp types than
any other manufacturer.
In 2006, the ECOLOGIC program celebrated its 10-year
anniversary. In those 10 years, we’ve avoided the use of
over 580 tons of lead from our soldering production, and
we’ve reduced the amount of mercury used in many of
our lamps by up to 92%.
ECOLOGIC lamps have little or no lead in their glass or
bases, and little or no mercury in the HID and fluorescent
lamp types. Many of these products also offer additional
“green” features such as energy efficiency and long life, and
are packaged using recycled and/or recyclable materials.
iv
THIS PROGRAM IS CURRENTLY AVAILABLE ONLY IN THE U.S.A.
v
Energy and the Cost of Lighting
According to the U.S. Department of Energy, we consume about one-quarter of our electricity for lighting,
at a cost of more than $37 billion annually. Lighting accounts for the single largest portion of electric bills
for commercial users, as much as 30% — and it can be a prime opportunity for reducing energy costs.
Saving energy, saving money
Energy costs represent your biggest and best opportunity
for savings. Even seemingly minor energy efficiency improvements can have a major positive impact on operating expenses — long-term savings that can quickly repay the
minimal capital investment.
Where does the cost of the average lighting
system come from?
• Materials — the initial investment in fixtures,
lamps, wires and ballasts
• Labor — the cost to install the lighting and maintain it
day-to-day
• Electricity — the energy consumed to illuminate
the lamps
• Recycling — removing and disposing of spent lamps
in a way that does not negatively impact the environment
For example, here are some things you can do right now:
• Upgrade to SYLVANIA Energy Saving lighting products to
significantly reduce total energy usage and operating costs.
• Replace traditional T12 fluorescent systems with
SYLVANIA OCTRON® T8 fluorescent lamps and SYLVANIA
QUICKTRONIC® electronic ballasts for up to 50% energy
savings.* You’ll also get the added assurance of QUICK
60+®, the industry’s first and most comprehensive lighting
system warranty.
• Implement a lighting maintenance and retrofit strategy to
maintain safety, security, aesthetics and productivity, as well
as to reduce labor costs. Our own SYLVANIA Lighting Services can help.
• Install dimmers and lighting control systems to save additional energy and add lighting design flexibility.
Figure 1
Cost of Maintaining the Average
Lighting System
1%
Recycling
86%
Energy
10%
Labor
3%
Material
As Figure 1 shows, the material
cost of a lighting system: bulbs,
ballasts and wiring, is small in
relation to the cost of the energy
to light it.
OCTRON T8 fluorescent lamps—savings the world
can live with
In 1981, OSRAM SYLVANIA invented the OCTRON T8
fluorescent lamp, ushering in a new era of energy efficiency in
lighting. Since we introduced the SYLVANIA OCTRON family,
we’ve saved our customers more than $27 billion in electricity
costs*. We’ve avoided 4 tons of airborne mercury discharged
from power plants**, and saved enough electricity to run the
Las Vegas Strip for 156 years!
Advances in lighting technology have improved the energy
efficiency of lighting by 30-60%, improvements that reduce
environmental impacts while increasing the bottom line.
Energy-efficient lighting requires less energy, which lowers
electricity demand. With less demand, power plants burn
less fossil fuel, reducing emissions of mercury and other air
pollutants. So everybody profits.
Energy-efficient systems
An important direction in lighting technology is the move toward systems. OSRAM SYLVANIA started the trend with THE
SYSTEM SOLUTION,® a family of optimally balanced energysaving lamps and electronic ballast combinations. By bringing
lamp and ballast development under an integrated system
concept, we have been able to design innovative SYLVANIA
lighting systems that optimize energy savings without sacrificing other elements of performance.
Rebates and tax benefits
As a way to reduce overall electricity demand, many utilities
offer rebates to commercial customers who upgrade the
efficiency of their lighting systems. Check with your local
utility or ESCO to learn more about these additional savings
opportunities. In addition, the Federal Energy Policy Act
of 2005 (EPAct 2005) offers tax benefits for energy-efficiency
upgrades in commercial buildings undertaken in 2006
and 2007. (For more information, please visit
www.sylvania.com/EPACT).
OSRAM SYLVANIA has the competitive advantage, with
years of experience in designing, developing and supporting
integrated systems — both in ballasts and lamps. Our global
network of design and manufacturing brings ballast and lamp
knowledge together to produce innovative, cost-effective,
energy saving systems.
* Based on $.10/kWh
** U.S. Department of Energy emissions conversion calculations
vi
SYLVANIA Products and the IESNA
Progress Report
A Proud Legacy of Achievement
Each year, The Progress Committee of the Illuminating Engineering Society of North America (IESNA) solicits the lighting
industry for product submissions which, if accepted by the
committee, are featured in the committee’s Progress Report,
which is published in the IESNA’s publication “Lighting Design &
Application”. The mandate of the Progress Committee is “to
keep in touch with developments in the art and science of lighting throughout the world and prepare a yearly review of
achievements for the Illuminating Engineering Society of North
America.” Submissions are organized into one of seven catego-
ries: light source, accessory, luminaire, research, application,
publication and design tool. They are evaluated for their design,
engineering characteristics, installation features and overall
uniqueness. The 30-member committee of industry experts
votes on up to 200 product submissions annually.
Over the years many SYLVANIA and OSRAM branded products have been accepted for the Progress Report. An itemized
list of these products and their significant features, are listed in
the tables that follow.
2007 Progress Report
OSRAM SYLVANIA submissions accepted by the
IESNA Progress Report
Significance to the Lighting Industry
OPTOTRONIC® 3W/350 mA LED Power Supply
Smallest constant current power supply – lower than 5W for max
power flexibility.
OPTOTRONIC 96W/24V LED Power Supply
Only 96w power supply that contains fittings and junction boxes.
IP66 rated. Universal voltage.
OPTOTRONIC 240W/24V LED Power Supply
Only 240W power supply that contains fittings and junction boxes.
IP66 rated. Universal voltage. 3 independently switchable channels.
QUICKTRONIC® QHE2x59/UNV-ISL-SC Ballasts
First high efficiency, low ballast factor, universal input voltage,
instant start ballast for 8 foot T8 lamps.
QUICKTRONIC QHE2x59/UNV-ISH-SC Ballasts
First high efficiency, high ballast factor, universal input voltage,
instant start ballast for 8 foot T8 lamps
QUICKTRONIC QHE2x86WT8HO/UNV-PSN-HT Ballasts
First high efficiency, normal ballast factor, universal input voltage,
programmed start ballast for 8 foot T8/HO lamps
QUICKTRONIC QHE 3 & 4 32T8/347V ISH HT Ballasts
First high efficiency, 347V, high ballast factor, instant start ballasts for
4 foot T8 lamps
QUICKTRONIC QHE 3 & 4 32W T8 480V Ballasts
First high efficiency, 480V, high ballast factor, instant start ballasts for
4 foot T8 lamps
QUICKTRONIC QHE 2x40DL UNV ISN SC Ballasts
First high efficiency, 2-lamp universal voltage ballasts for DULUX L
SUPERSAVER 40W and 28W lamps
QUICKTRONIC QHE 2,3,4 32T8 UNV PSH – HT Ballasts
First high efficiency, programmed start, 90°C rated ballasts for T8 lamps
QUICKTRONIC QHE 1,2,3,4 x32T8 UNV Type CC and Anti-Striation
Control Ballasts
First high efficiency T8 ballasts that operate more lamp types than
any other type CC ballast. -20°F starting temperature
QUICKTRONIC QTP2x54T5HO UNV PS80 SC Ballasts
First high efficiency T5HO ballast with 0.80 ballast factor for
20% energy savings
QUICKTRONIC QS2X54T5HO UNVPS80SC Ballasts
First high efficiency T5HO ballast with 0.80 ballast factor for
20% energy savings with bi level switching
QUICKTRONIC POWERSENSE T5 Dimming Ballasts
First high efficiency dimming ballasts for T5 lamps – dual control
(0-10V & line voltage), universal voltage
QUICKTRONIC Helios 0-10V T8 Dimming Ballasts
First high efficiency dimming ballasts for T8 lamps with up to 1.2 ballast
factor, auto start & restart technology 277V
METALARC® POWERBALL® 250W Ceramic Metal Halide Lamps
Smallest 250W single-ended ceramic metal halide in the industry.
20, 39, 70W METALARC POWERBALL Ceramic lamps with secure-fit
G8.5 base design
Industry’s first formed press G8.5 base low wattage CMH lamp.
OCTRON® SKYWHITE T8 Fluorescent Lamps
Industry’s first 8000K T8 lamp
®
®
PENTRON PREMIER ECOLOGIC T8 Fluorescent Lamps
Industry’s highest lumen 28W lamps.
vii
2006 Progress Report
OSRAM SYLVANIA submissions accepted by the IESNA Progress Report
Significance to the Lighting Industry
20W METALARC® POWERBALL® Ceramic Metal Halide PAR 30 Lamp
Highest lamp life for 20W PAR 30 CMH.
39W METALARC POWERBALL Ceramic Metal Halide PAR 20 or PAR 30 Lamp
Highest CRI PAR 20 or PAR30 CMH – 5% improvement.
750W SUPER METALARC® Pulse Start
First base down 750w MH Pulse Start lamp.
®
54W PENTRON HO Primary Colors T5 Fluorescent Lamps
First T5 HO single phosphor lamps.
aluPAR™ – Lighter, brighter, cooler PAR 56 Stage & Entertainment Lamp
First lightweight, aluminum reflector PAR 56. Lamp can be disassembled for
recycling. Up to 50% lighter and 10% brighter.
QUICKTRONIC® QHE High Efficiency Family of 347V 4 – Lamp T8 Ballasts
First high efficiency T8 Instant Start low ballast factor ballast for 347V systems.
QUICKTRONIC QHE High efficiency Family of 347V T8 Instant Start Ballasts
First high efficiency T8 Instant start normal ballast factor ballast for 347V systems.
QUICKTRONIC QHE 3X40DL UNV IS T5 Ballasts
First high efficiency universal voltage ballast that can operate 3 DL40W or
3 DL40/28W SS lamps.
OCTRON® FBO29/800XP/SS/ECO 29W T8 Fluorescent Lamp
First 29W 1-5/8" leg U-bent lamp.
DRAGONstick
Expansion of DRAGON product family, includes heatsinks and available in 3300K.
DRAGONpuck Warm White
Expanded DRAGONpuck product family – 3300K version.
DRAGONtape Warm White
Expanded DRAGONtape product family – 3300K version.
HF2 Linear LED module
First integrated LED strip with heat sink and optics. Increases accessibility of
LED to non LED manufacturers.
HF2 Eye LED module
First integrated LED point source with heat sink and optics. Increases accessibility
of LED to non LED manufacturers. IP65 rated.
HF2X LED Module
Smallest 6 LED array with high luminance LEDs with optics.
OStar® Lighting LED component
Smallest 6 LED array with high luminance LEDs.
2005 Progress Report
OSRAM SYLVANIA submissions accepted by the IESNA Progress Report
Significance to the Lighting Industry
MINISTAR® Lamp
Smallest low voltage bi-pin halogen reflector lamp.
®
®
70W METALARC POWERBALL PLUS Ceramic Metal Halide Lamps
(3000K, 95 CRI)
Highest CRI of 3000K CMH lamps.
320W METALARC POWERBALL Ceramic Metal Halide Lamp
HIghest initial LPW (117LPW) for a 320W CMH lamp.
70W METALARC POWERBALL PAR30 Ceramic Metal Halide Lamp
First CMH lamp with neodymium glass.
®
70 and 100W LUMALUX PLUS High Pressure Sodium Lamps
First non-cycling medium based HPS lamp.
39W METALARC POWERBALL Ceramic Metal Halide Lamp
Longest life 4000K 39W CMH lamp (12,000 hrs)
®
920W SUPER METALARC Metal Halide Lamp
First 920W metal halide lamp direct retrofit for 1000W.
PENTRON® Constant HO ECOLOGIC® T5 Fluorescent Lamp
First T5 HO lamp with amalgam technology.
ICETRON® Reflector ECOLOGIC Inductively Coupled Electrodeless
Fluorescent Lamp
First induction lamp with an internal reflector.
OCTRON® FBO29/800XP/SS/ECO 29Watt T8 Fluorescent Lamp
First 29W 1-5/8" leg u-bent lamp.
®
OPTOTRONIC Constant Current Dimmable LED Power Supply for DRAGONtape
and DRAGONpuck
First LED driver for DRAGONtape and DRAGONpuck module.
OPTOTRONIC Dimmable LED power supply for DRAGONtape and DRAGONpuck
First dimmable LED driver for DRAGONtape and DRAGONpuck.
DRAGONpuck LED Module
First high brightness LED with integrated optics.
DRAGONtape LED Module
Modular, high brightness configurable LED strip.
OPTOTRONIC LED power supply, 24V, 75W
First 75W universal voltage LED power supply.
OPTOTRONIC OTO50/120-277/10E LED Power Supply
First 50W universal voltage LED power supply.
viii
Product Catalog Glossary of Terms
Ampere A unit expressing the rate of flow of
electric current.
Ballast Fusing (See Fusing.)
ANSI (American National Standards
Institute) The organization that develops
designed to have an average life expectancy of
60,000 hours. To maximize life, ambient temperature
should be kept as low as possible. It is also important to maintain effective dissipation of heat using the
lighting fixture as a heatsink for the ballast enclosure.
voluntary guidelines and produces performance
standards for the electrical and other industries.
Audible Noise (Sound) All fluorescent lamp
ballasts produce some noise. Most OSRAM
SYLVANIA brand ballasts are sound rated A (up
to 75% quieter than magnetic types) and are
acceptable for most applications. Care should
be taken when mounting the ballast to reduce
vibration.
Average Rated Life An average rating, in hours,
indicating when 50% of a large group of lamps
have failed, when operated at nominal lamp voltage and current; manufacturers use 3 hours per
start for fluorescent lamps and 10 hours per start
for HID lamps when performing lamp life testing
procedures; every lamp type has a unique mortality curve that depicts its average rated life. For
Photo-Optic specialty lamps, average rated life
refers to the operating period after which on statistical average, 50% of the lamps will perform within
their specified values.
Ballast A device used with an electric discharge
lamp to obtain the necessary circuit conditions
(voltage, current and waveform) for starting and
operating; all fluorescent and HID light sources
require a ballast for proper operation. Dimming
ballasts are special ballasts which, when used
together with a dimmer, will vary the light output of
a lamp. OSRAM Photo-Optic discharge lamps are
either designed for AC operation (sine wave and/or
square wave with recommended operational frequencies below 1KHz) or DC operation (current
regulated or power regulated). Please see OSRAM
lamp specifications for correct ballast or electronic
control gear selection.
Ballast Basics Ballasts have two primary functions: 1) start the lamp and 2) control operation
of the lamp once it has started. High frequency
electronic ballasts operate lamps more efficiently
and eliminate the hum and visible flicker normally
associated with standard magnetic ballasts.
Electronic ballasts also typically have better power
quality than magnetic ballasts.
Ballast Efficacy Factor (BEF) Ballast factor (as
a whole number) divided by input power (watts).
Used to measure the level of efficiency of similar
ballast models. For example, the OSRAM SYLVANIA QT2X32IS which has a ballast factor of 0.90
and input watts of 59 (BEF= 90/59 = 1.53), is
more efficient than electronic ballasts with ballast
factor of 0.875 and input watts of 62 (BEF=1.41).
Ballast Factor (BF) The measured ability of a
particular ballast to produce light from the lamp(s)
it powers; ballast factor is derived by dividing the
lumen output of a particular lamp/ballast combination by the lumen output of the same lamp(s) on a
reference ballast.
Ballast Life OSRAM SYLVANIA ballasts are
Ballast Losses Power consumed by a
ballast that dissipates as heat instead of being
converted into light. Electronic ballasts operate
more efficiently than magnetic or hybrid ballasts. A
typical ballast loss for a standard two lamp energy
saving magnetic ballast is 12 watts, where an
electronic equivalent would only be 7 watts.
Ballast Types There are three types of lighting
ballasts: 1) Magnetic: an inefficient device that
uses a core and coil assembly transformer to
perform the minimum functions required to start
and operate the lamp; 2) Hybrid or “low frequency
electronic”: essentially a magnetic ballast with a
few electronic components that switch off voltage
to the lamp coil once the lamp has started. A minimal increase in efficiency is obtained via more
expensive magnetic core material and the absence
of power to the lamp coils during operation; 3) High
frequency electronic: a ballast that operates lamps
at frequencies above 20,000 Hz. Maximum efficiency is obtained through the use of electronic circuitry
and optimum lamp operating characteristics.
Base The lamp base mechanically holds the lamp
in place in the application. The lamp base directly
or indirectly (via a cable or lead-in wires) conducts
electricity from the circuit to the lamp and can be
designed to dissipate heat. Lamp bases should be
operated within specified temperature ranges.
Beam Angle The angle between the two direc-
Center Beam Candlepower (CBCP) The
intensity of light produced at the center of a
reflector lamp beam, expressed in candelas.
Chromaticity The aspect of color that includes
consideration of its dominant wavelength and purity.
Color Rendering Index (CRI) The Color
Rendering Index (CRI) measures the effect a light
source has on the perceived color of objects and
surfaces. High CRI light makes virtually all colors
look natural and vibrant. Low CRI causes some
colors to appear washed out or even to take on a
completely different hue.
Color Temperature (CT) Color temperature,
which is measured in Kelvin, indicates whether a
lamp has a warm, midrange or cool color appearance. “Warm” light sources have a low color temperature (2000-3000K) and feature more light in
the red/orange/yellow range. Light with a higher
color temperature (>5000K) features more blue light
and is referred to as “cool.”
Compact Fluorescent Lamps Compact
fluorescent lamps employ small diameter tubes that
are bent so they begin and end in a single base.
This allows them to be produced in a wide variety
of configurations, greatly extending the applications for fluorescent lighting.
Correlated Color Temperature (CCT)
A specification of the color appearance of a
lamp, relating its color to that of a reference
source, black body radiator, heated to a particular temperature, measured in degrees Kelvin (K);
CCT generally measures the “warmth” or “coolness” of light source appearance.
Current A measure of the rate of flow of
electricity, expressed in amperes (A).
tions for which the intensity (candlepower) is 50%
of the maximum intensity as measured in a plane
through the nominal beam centerline (center beam
candlepower).
Description (See Ordering Abbreviation.)
Beam Spread In any plane, the angle between
the two directions in the plane in which the candlepower is equal to a stated percent of the maximum candlepower in the beam.
Directional Lighting Illumination on the work-
Black Body (Planckian radiator) An ideal
thermal radiator whose SPD curve is defined by its
temperature in Kelvin and whose color coordinates
lie exactly on the Planckian curve.
Brightness (See Luminance.)
Bulb Hard, soft or quartz glass enclosure, which
can contain a vacuum, elemental inert gas or
metal and a means of light generation (filament or
electrodes).
Candela (cd) The unit of measure indicating the
luminous intensity (candlepower) of a light source
in a specific direction; any given light source will
have many different intensities, depending upon
the direction considered.
Candlepower Distribution A curve that represents the variation in luminous intensity (expressed
in candelas) in a plane through the light center of a
lamp or luminaire; each lamp or lamp/luminaire
combination has a unique set of candlepower distributions that indicate how light will be spread.
ix
Design Amperes The approximate current
which the lamp will draw at design volts.
plane or on an object predominantly from a single
direction.
Double-Ended Lamps that have two bases
opposite one another for series electrical connection, mechanical mounting and heat dissipation.
Efficacy The rate at which a lamp is able to convert power (watts) into light (lumens), expressed in
lumens per watt (LPW or lm/W). See also LPW
Performance.
Electronic Control Systems (See Ballast.)
EMI/RFI Electronic Ballasts contain circuits that
limit electrical noise conducted onto the power line
or radiated through the air, otherwise referred to as
EMI/RFI. OSRAM SYLVANIA ballasts comply with
FCC 47 CFR Part 18, non-consumer limits for
commercial applications. Ballasts for residential
application must meet consumer limits. OSRAM
SYLVANIA has a complete line of magnetic ballasts for residential use.
Energy A measure of work done by an electrical
system over a given period of time, often
expressed in kilowatt-hours (kWh).
Hertz (Hz) A unit of frequency equal to one cycle
per second; see frequency.
Filament A tungsten wire purposely positioned
Lamps in which an arc passing between two electrodes in a pressurized tube causes various metallic
additives to vaporize and release large amounts of
light. All HID lamps offer outstanding energy efficiency and service life. Metal halide lamps also
offer good to excellent color rendering index (CRI).
inside a lamp bulb, that when heated electrically
generates radiation in the visible, infrared and ultraviolet ranges. Tungsten material is most often
used, as it has great tensile strength, is very
durable, and can be heated very near its melting
point without evaporating rapidly. Lamp filaments
are offered in a variety of designs optimized for
specific applications.
High-Intensity Discharge (HID) Lamps
Hot Ignition The restarting of a previously
Fixture (See Luminaire.)
operating lamp shortly after turn-off. Hot ignition
is a high performance feature in many OSRAM
SYLVANIA discharge lamp types.
Floodlight A reflector lamp with a relatively wide
Illuminance Light arriving at a surface, expressed
beam pattern. Also a luminaire consisting of lamp
and reflector at fixed distance providing a wide
field of illumination.
in lumens per unit area; 1 lumen per square foot
equals 1 footcandle, while 1 lumen per square
meter equals 1 lux.
Fluorescent Lamp A low pressure mercury
Incandescent Lamp A light source using
vapor discharge light source. The electric discharge
generates ultra-violet (UV) energy, which is absorbed
by a phosphor and converted to visible light.
the principle of incandescence. When an electric
current passes through a filament wire (usually tungsten), the heated wire glows. Filaments of standard
incandescent lamps are enclosed in a vacuum or
gas-filled bulb. They provide low initial cost, good
color rendition and excellent optical control.
Focal Distance The distance between a lamp
(light producing element) and the focal point of
the reflector surrounding it. Lamp alignment can
be adjusted to influence both illumination and
color quality. Sometimes referred to as “working
distance”.
Footcandle (fc) A unit of illuminance equal to
1 lumen per square foot.
Frequency The number of times per second that
an alternating current system reverses from positive to negative and back to positive, expressed in
cycles per second or hertz (Hz).
Fusing All QUICKTRONIC® ballasts contain
inherent electrical protection. Although there is
no need to externally fuse the ballast, should
code or regulation require one, 3 amp slow blow
fuses are recommended.
Instant Start (IS) Instant start ballasts apply high
voltage across the lamp with no preheating of the
cathode. This is the most energy efficient starting
method for fluorescent lamp ballasting. IS ballasts
use 1.5 to 2 watts less per lamp than rapid start
ballast. Other IS ballast benefits typically include
parallel lamp circuitry, longer remote wiring distance, easier installation due to less complicated
wiring, and capability to start lamps at 0 degrees
(versus 50 degrees F for rapid start).
K-Factor A measurement that quantifies the
Glow to Arc Transition In order to achieve full
effect of non-linear equipment, such as lighting
ballasts, on an electrical system. Lighting systems
should be designed so that the transformer rating
is sufficient for the ballast used (typically K-factor
<4). All OSRAM SYLVANIA ballasts meet this
specification.
rated lamp life, a ballast should start a lamp so
that the time from when the lamp begins to glow
to the time the lamp arc strikes should be as short
as possible. OSRAM SYLVANIA instant start ballasts typically accomplish this task within 50 msec.
Lamp Manufactured light source, synonymous
with light bulb; the three broad categories of
electric lamps are incandescent, fluorescent
and high-intensity discharge.
Grounding The ballast case and fixture must
Lamp Current Crest Factor (LCCF) The ratio
always be grounded. The grounding helps assure
safety, proper lamp starting, and acceptable EMI/RFI
performance. Install ballast in accordance with national and local electric codes.
Halogen Lamps High pressure tungsten
filament lamps containing halogen gases. The
halogen gases allow the filaments to operate at
higher efficacies than incandescent lamps.
Halogen lamps also provide brighter, whiter light
with better color characteristics, longer service
life and improved energy efficiency.
Harmonic An electrical frequency that is an
integer multiple of the fundamental frequency; for
example, if 60 Hz is the fundamental frequency,
then 120 Hz is the second harmonic and 180 Hz
is the third harmonic. Some electronic devices,
such as ballasts or power supplies, can cause
harmonic distortion, directly affecting power quality.
of peak lamp current to the RMS (average) lamp
current. Lamp manufacturers require a LCCF of
less than 1.70 in order to achieve full lamp life.
Lamp Lumen Depreciation Factor (LLDF)
The multiplier to be used in illumination calculations to relate the initial rated output of light
sources to the anticipated minimum rated output
based on the relamping program to be used.
(See Lumen Depreciation and Mean Lumens.)
Lens A glass or plastic element used in luminaires
to change the direction and control the distribution
of light rays.
Light Radiant energy that is capable of producing
a visual sensation.
Light Center Length (LCL) The distance from
a specified reference point on a lamp base
to its light center.
Light Loss Factor (LLF) A factor used in
calculating illuminance after a given period of time
and under given conditions. It takes into account
temperature and voltage variations, dirt accumulation on luminaire and room surfaces, lamp depreciation, maintenance procedures and atmosphere
conditions. Formerly called maintenance factor.
Low Temperature Starting QUICKTRONIC®
instant start and programmed rapid start electronic ballasts have the capability to start fluorescent
lamps at temperatures down to 0°F providing the
following conditions are met: 1. The ballast is
operated at rated nominal line voltage; 2. Ballast
cannot be tandem/remote wired for low temperature starting applications. Please note, starting
time may increase at 0°F ambient temperatures.
Enclosed fixtures are recommended as fluorescent lamps have reduced light output at cooler
ambient temperatures. (See specifications for
each model’s starting temperature rating.)
LPW Performance Lumens Per Watt. The
number of lumens produced by a light source for
each watt of electrical power supplied to the light
source. Also see Efficacy.
Lumen Depreciation The decrease in lumen
output of a light source over time; every lamp type
has a unique lumen depreciation curve (sometimes
called a lumen maintenance curve) depicting the
pattern of decreasing light output. See Lamp Lumen
Depreciation Factor, LLDF and Mean Lumens.
Lumen Maintenance (See Lumen Depreciation.)
Lumens (lm) A unit of luminous flux; overall light
output; quantity of light, expressed in lumens. For
example, a dinner candle provides about 12
lumens and a 60-watt soft white incandescent
lamp provides about 840 lumens.
Lamp Disposal When disposing of spent lamps,
always consult federal, state, local and/or provincial
hazardous waste disposal rules and regulations to
ensure proper disposal.
Luminaire A light fixture; the complete lighting
Lamp Flicker Cyclic variation in output of a light
source. High frequency electronic ballasts provide
a minimal level of lamp flicker. Lamp flicker from
magnetic ballasts may cause eye fatigue for some
people.
Luminaire Efficiency The ratio of luminous flux
(lumens) emitted by a luminaire to that emitted by
the lamp or lamps used therein.
Lamp Fuse Wire or device designed to protect a
lamp from over-voltage or over-current conditions.
OSRAM requires that all Photo-Optic lamps be
fused in their applications to prevent lamp overpowering. Certain lamps contain their own internal
fuse. Please ensure lamps in your specific application are fused with respect to their power source.
x
unit, including lamp, reflector, ballast, socket,
wiring, diffuser and housing.
Luminance (L) Light reflected in a particular
direction; the photometric quantity most closely
associated with brightness perception, measured
in units of luminous intensity (candelas) per unit
area (square feet or square meters).
010_INC_drop.qxd
12/4/07
8:19 AM
Page 1
I
N
C
A
N
D
E
S
C
E
N
T
INCANDESCENT LIGHTING
The incandescent lamp consists of a wire filament on a suitable mount enclosed in a glass bulb containing a gas or a vacuum.
When the lamp is connected to an electrical circuit, the current passing through the wire must overcome the filament’s
resistance, and the power consumed heats the filament to incandescence (causes it to glow).
Q U AL IT Y L IG H T
Incandescent bulbs are still the standard choice when the quality of light really counts. The different shapes, coatings and features provide
a variety of options for many lighting applications. With warm color temperatures and superior color rendering, nothing sets the mood like
incandescent lighting.
THE BEST QUALITY OF LIGHT FOR:
Atmospher e
Romance
W ar mth
Beauty
Comfor t
Elegance
Q U AL IT Y C O N S T R U C T IO N
SYLVANIA uses the highest quality components designed to offer superior performance on every lamp.
Variety of coatings and
finishes
Double coil
and filament support
Fused Lead wires
High performance
base cement
Lead-free solder
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 35-39
1
010_INC_drop.qxd
12/4/07
8:19 AM
Page 2
LAMP CATEGORIES
I
N
C
A
N
D
E
S
C
E
N
T
SYLVANIA offers a wide assortment of premium lighting products that add value through superior performance, long life, beautiful light
and rugged durability.
Do u b l e L i fe
Our long-life line of premium light bulbs
Long Life without compromising brightness and light quality
• Lasts up to twice the life of a regular light bulb with almost the
same light output
• Available in many different shapes and sizes
Perfect for hard to reach applications
Daylight®
Our most pleasing light
Unique coating that simulates natural light
• Delivers whiter, more natural light
• Enhances color performance, vivid colors
The best choice to bring more natural light indoors
R o u g h Se r v ic e
Our toughest line of light bulbs
Able to withstand knocks and bumps
• Extra support
• Most durable construction
Ideal for applications where lamp may
be subject to vibration
Sa f e l i n e ®
Our safest light bulbs
Shatter resistant, weather resistant
• Safely contains glass in case of breakage
• Provides weather protection
• Provides weather and moisture resistance making bulbs ideal
for indoor and outdoor applications.
Appropriate when safety comes first
Sp e c i a l t y
Our complete assortment of specialized light bulbs
Diverse line of light bulbs for specific uses
• SPOT-GRO®
• Heat Lamps
• Night Lights
• Colored Lamps
• Appliance Lamps
• Street lighting
High quality lamps for multiple applications
For more complete product information visit www.sylvania.com
2
Symbols/Footnotes on page 35-39
010_INC_drop.qxd
12/4/07
8:19 AM
Page 3
BULB IDENTIFICATION
I
N
C
A
N
D
E
S
C
E
N
T
Bulb size - Max. Diameter (Divide by 8)
Light Center Length (L.C.L.) is the distance
from the center of the light source to the following point for the base used: Screw
bases...bottom base contact; Bayonet candelabra and medium bayonet...top of base pins.
A-21 - 21⁄8 = 2 5⁄8” Dia.
G-40 - 40⁄8 = 5” Dia.
T-12 - 12⁄8 = 1 1⁄2” Dia.
PS-30 - 30⁄8 = 3 3⁄4” Dia.
BASE IDENTIFICATION
Typical bases are shown. One lead-in wire is
soldered to the center contact and the other
soldered or welded to the upper rim of the
base shell. Base shells are typically made of
brass or aluminum. ANSI designations are in
parentheses.
Candelabra
cand. (E12)
Intermediate
Inter. (E17)
Medium (E26) &
Medium Brass
(E26)
3 Contact
Medium
3 C Med (E26D)
Medium Skirted
Med. Skirt
(E26/50x39)
Ext. Mogul
End Prong GX16d
Mogul Screw
3 Contact Mogul
Double Contact
Bayonet D.C.
Bay (BA15D)
Mogul End Prong
S14s
Med Side Pr.
Screw Terminal
G53
FILAMENT IDENTIFICATION
A FILAMENT designation consists of a prefix
letter to indicate whether the wire is straight or
coiled, and a number to indicate the arrangement of the filament on the supports. Prefix
letters include: C (coiled) --wire is wound into
a helical coil or it may be deeply fluted; CC
(coiled coil)--wire is wound into a helical coil
and this coiled wire again wound into a helical
coil.
ADDITIONAL INFORMATION
Lamps Listed 115-125 volts (design voltage
120), 120-130 volts (design voltage 125),
125-130 volts (design voltage 130) and 230250 volts (design voltage 240) are intended
for use on circuits normally varying within
these voltage limits.
For more complete product information visit www.sylvania.com
C-8
CC-8
C-9
CC-9
C-6
CC-6
C-2V
CC-2V
C-11V
C-11
CC-11
C-5
C-2R
C-7A
CC-7A
Finishes
W or SW - Soft White
DAY - Daylight®
Y - Yellow
B - Blue
R - Red
G - Green
A - Amber
IC - Iridescent clear
FL - Flood
SP - Spot
IF - Inside frost
AIC - Amber iridescent clear
Symbols/Footnotes on page 35-39
3
010_INC_drop.qxd
12/4/07
8:19 AM
Page 4
INCANDESCENT LAMP SHAPES
I
N
C
A
N
D
E
S
C
E
N
T
A bulb designation consists of a letter(s) to indicate the shape and
a figure(s) to indicate the approximate major diameter in eighths of
in inch. For example, an F-15 bulb is a flame-shape, 15/8 of an
inch or 1-7/8 inches in diameter.
B10 Blunt Tip
B10 Crystal
B10 Cand
B13 Cand
F15 Med
C7 Cand
LINESTRA 2-base
T6 Cand
T6.5 Inter
T6.5 DC Bay
BR30 Med
P25 Med
PAR46 Med
Sid Pr
T7 Cand
S6 Cand
T7 DC Bay
T7 Inter
BR40 Med
PS25 3C
Mog
PS25 Med
T8 Cand
ER30 Med
PS30 Med
PAR56 Scrw Trm
For more complete product information visit www.sylvania.com
4
C7 DC Bay
A15 Med
C15 Med
S6 DC Bay
T8 DC Bay
T8 Inter
CA
S11 Cand
T10 Med
PAR38 Med
Skrt
PAR56 Mog
End Pr
G16.5 Cand
S11 DC Bay
R14 Inter
A19 Med
G16.5 Med
S11 Inter
R14 Med
R40 Med Skrt
ER40 Med
PS35 Mog
A17 Med
PAR38 Med
Sid Pr
PAR64 Scrw Trm
A21 Med
A21 3C Med
G25 Med
S11 Med
G40 Med
G30 Med
S14 Med
R16 Med
A23 Med
S 19 Med
R20 Med
K19 Med
R40 Mog
R40 Med
PAR46 Scrw Trm
PAR46 Mog
End Pr
PAR64 Ex Mog
End Pr
Symbols/Footnotes on page 35-39
010_INC_drop.qxd
12/4/07
8:19 AM
Page 5
HOW TO READ PRODUCT INFORMATION - INCANDESCENT
34
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
Class &
Filament
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
I
N
C
A
N
D
E
S
C
E
N
T
|
|
|
Bulb
Describes the shape of the envelope followed by the lamp’s major diameter given in eighths of an inch.
See page 4: Incandescent Lamps.
Base
See page 3: Base Identification.
Symbols &
Footnotes
All symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and foot
notes are at the end of the incandescent section.
Ordering
Abbreviation
A text description of the lamp. See below for several examples and explanations of some of the codes.
Class &
Filament
The class is either B (vacuum) or C (gas filled). The filament designation describes the shape and mount structure of the filament.
See page 3: Filament Identification.
Lumens,
Beam Angle,
CBCP
This column may contain data for any of these values. Lumen values are followed by the designation ‘lm’. Beam angles are
indicated by either a ‘°’ or the designation ‘V x H’ for non-symmetric beams. CBCP values are followed by the designation ‘cd’.
HOW TO READ ORDERING ABBREVIATIONS
40B10C/CRYSTAL/DL/BL/2PK
60A/DL/SW/2PK/RP
65BR30/DL/FL/RP
40
B
10
C
CRYSTAL
DL
BL
2PK
60
A
DL
SW
2PK
RP
65
BR
30
DL
FL
RP
Nominal lamp wattage
Bulb shape
Bulb size in 8th's of an inch
Candelabra base
Crystal texture on bulb glass
Double Life Lamp
Blister pack
2 lamps per package
Nominal lamp wattage
Bulb shape
Double life lamp
Soft white
2 lamps per package
Retail pack
Nominal lamp wattage
Bulb shape
Bulb size in 8th's of an inch
Double life lamp
Flood beam pattern
Retail pack
INCANDESCENT BRAND NAME GUIDE
NOTE: These tables are intended only as a guide and may represent another lamp company’s closest competitive type rather than an identical
match. Individual manufacturers’ performance values should be consulted. Environmental conditions, ballast type, and other auxillary equipment may affect lamp performance.
INCANDESCENT
SYLVANIA
GE*
PHILIPS**
Bug-Light
Bug-Lite
Bug-A-Way
Double Life
Long Life
Dura-Max
Double Life Soft White
Long Life Soft White
Dura-Max Soft White
Daylight®
Reveal
Natural
elogic™
Energy Saver Soft White
Soft White Miser
Econ-O-Watt
EXCEL-LINE®
Extended Service
Extended Service
LINESTRA®
Lumiline
RHINO COAT® SAFELINE®
COV-R-GUARD
Silicone Coated
Rough Service
Rough Service
Rough Service XL
Survivor
Soft Pink
Soft Pink
Softone Pastels
Spot-GRO®
House Garden - Plant Light
Agro-Lite
SUPERSAVER®
Watt-Miser
Econo-o-Watt
SUPERSAVER EXCEL-LINE
Watt-Miser Plus
Extended Service
SUPERSAVER PAR
Watt-Miser PAR
Econo-o-PAR
*Trademark and or registered trademark of General Electric Company. **Trademark and or registered trademark of Philips.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 35-39
5
010_INC_drop.qxd
12/4/07
8:19 AM
Page 6
NOTES:
I
N
C
A
N
D
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
6
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:57 AM
A17
Page 7
G16.5
A21
A15
A19
B10
G25
R20
BR30, BR40
ELOGIC™ LAMPS
Small Bulb. Big Difference
34
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
Description
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
38
A17
Med
10825
38A17/W/ELOGIC/4/48/RP
120 48
Soft White
C, CC-8
2250
410
2.88
3.75
57
A17
Med
11721
57A17/W/ELOGIC/4/48/RP
120 48
Soft White
C, CC-8
1500
740
2.88
3.75
71
A17
Med
10826
71A17/W/ELOGIC/4/48/RP
120 48
Soft White
C, CC-8
1125
1020
2.88
3.75
95
A17
Med
12953
95A17/W/ELOGIC/4/48/RP
120 48
Soft White
C, CC-8
1125
1500
2.88
3.75
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
3.00
MOL
(in)
I
N
C
A
N
D
E
S
C
E
N
T
|
|
|
®
DAYLIGHT LAMPS
White & Natural
34
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
Description
Class &
Filament
25
G16.5 Candelabra
10221
25G16.5C/DAY/2PK/BL
120 12
Daylight Globe
C, C-7A
1500
30
70
100
A21
19395
30/100/DAYLIGHT/1/12
120 12
Daylight 3-Way
C, CC-8
1200
40
3 CONTACT
Med
220lm
700lm
920lm
3.38
5.31
A15
Med
10181
40A15/DAY/FAN/BL/2/24
120 24
Daylight Fan
C, C-9
1000
340
2.38
3.50
A19
Med
10897
40A/DAY/4/160/RP
120 160
Daylight
C, CC-8
1500
350
3.13
4.44
10864
40A/DAY/RP/4/48
120 48
Daylight
C, CC-8
1500
350
3.13
4.44
11100
40A/DAY/RP/2/24
120 24
Daylight
C, CC-8
1500
350
3.13
4.44
10829
99,136 40A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 33 watts, 270 lumens, 3750 hours.
Daylight
C, CC-8
1500
350
3.13
4.44
Candelabra
13751
40B10C/DAY/2PK/BL
120 12
Daylight Decor Bent Tip
C, C-7A
1500
3.88
Med
B10
15354
40B10/DAY/2PK/BL
120 12
Daylight Decor Bent Tip
C, C-7A
1000
3.88
G16.5 Candelabra
10367
40G16.5C/DAY/2PK/BL
120 12
Daylight Globe
C, C-7A
1500
3.00
G25
15350
40G25/CL/DAY/1/6
120 6
Daylight Clear Globe
C, C-9
1500
4.44
13966
40G25/DAY/1/6
120 6
Daylight Globe
C, C-9
1500
4.44
45R20/DAY/1/6/RP
120 6
Daylight Reflector
C, C-9
2000
50/150/DAY/1/12
120 12
Daylight 3-way
C, CC-8
1200
50R20/DAY/1/6/RP
120 6
Daylight Reflector
C, C-9
2000
Med
45
R20
Med
15677
50
100
150
A21
3 CONTACT
Med
18110
50
R20
Med
15231
2,46,68,155
2,46,68,107,
|
|
|
3.94
460lm
1170lm
1630lm
3.38
5.31
3.94
155
60
A15
Med
10162
60A15/DAY/FAN/BL/2/24
120 24
Daylight Fan
C, C-9
1000
340
2.38
3.50
A19
Med
11509
60A/DAY/4/160/RP
120 160
Daylight
C, CC-8
1000
640
3.13
4.44
11463
60A/DAY/RP/4/48
120 48
Daylight
C, CC-8
1000
640
3.13
4.44
11101
60A/DAY/RP/2/24
120 24
Daylight
C, CC-8
1000
640
3.13
4.44
11602
101,136 60A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 53 watts, 490 lumens, 2500 hours.
Daylight
C, CC-8
1000
640
3.13
4.44
B10
Candelabra
13750
60B10C/DAY/2PK/BL
120 12
Daylight Decor Bent Tip
C, C-7A
1500
3.88
G25
Med
15351
60G25/CL/DAY/1/6
120 6
Daylight Clear Globe
C, C-9
1500
4.44
13967
65
60G25/DAY/1/6
120 6
Daylight Globe
C, C-9
1500
4.44
2,46,57,
65BR30/DAY/1/6/RP
120 6
Daylight Reflector
C, CC-6
2000
5.38
46,57,155
65BR40/FL/DAY/1/6/RP
120 6
Daylight Reflector
C, CC-6
2000
6.50
10863
75A/DAY/4/160/RP
120 160
Daylight
C, CC-8
750
850
3.13
4.44
10865
75A/DAY/RP/4/48
120 48
Daylight
C, CC-8
750
850
3.13
4.44
BR30 Med
15223
BR40 Med
15487
A19
155
75
Med
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 35-39
7
010_INC_F.qxd
11/29/07
A19
7:57 AM
BR40
Page 8
C7 Candelabra
B10
G25
A21
A15
DAYLIGHT® LAMPS
White & Natural
I
N
C
A
N
D
E
S
C
E
N
T
34
Watts Bulb
Base
75
Med
A19
BR40 Med
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
11102
75A/DAY/RP/2/24
A19
Med
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
120 24
Daylight
C, CC-8
750
850
3.13
4.44
10776
102,136 75A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 66 watts, 650 lumens, 1875 hours.
Daylight
C, CC-8
750
850
3.13
4.44
15349
46,57,107,
75BR40/FL/DAY/1/6/RP
120 6
Daylight Reflector
Flood
C, CC-6
2000
155
100
Description
Class &
Filament
|
|
|
6.50
12948
100A/DAY/4/160/RP
120 160
Daylight
C, CC-8
750
1270
3.13
4.44
12587
100A/DAY/RP/4/48
120 48
Daylight
C, CC-8
750
1270
3.13
4.44
12952
100A/DAY/RP/2/24
120 24
Daylight
C, CC-8
750
1270
3.13
4.44
12538
103,136 100A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 88 watts, 970 lumens, 1875 hours.
Daylight
C, CC-8
750
1270
3.13
4.44
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
2.13
DOUBLE LIFE LAMPS
Lasts 2X longer than ordinary Soft White lamps
34
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
4
C7
Candelabra
13523
4C7/DL/BL/4PK
120 48
Double Life Night Light
B, C-9
6000
15
B10
Candelabra
13315
15B10C/DL/BL
120 12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
25
B10
Candelabra
13306
25B10C/DL/BL/4PK
120 24
Clear Double Life Decor
Bent Tip
C, C-7A
3000
3.88
13316
25B10C/DL/BL
120 12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13743
25B10C/CRYSTAL/DL/BL/2PK
120 12
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13308
25B10C/DLF/BL/4PK
120 24
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13317
25B10C/DLF/BL
120 12
Frosted Double Life
Decor Bent Tip
C, C-2V
3000
3.88
Med
G25
30
70
100
A21
Med
3CONTACT
Med
Description
Class &
Filament
14
13331
94
25B10/DL/BL/4PK
120 24
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
13318
94
25B10/DL/BL
120 12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
14105
25G25/DL/RP/48
120 48
Clear Double Life Globe
C, C-9
3000
4.44
14145
25G25/DL/RP
120 6
Clear Double Life Globe
C, C-9
3000
4.44
14103
25G25/DL/SW/RP/48
120 48
Soft White Double Life
Globe
C, C-9
3000
4.44
14146
25G25/DL/SW/RP
120 6
Soft White Double Life
Globe
C, C-9
3000
4.44
30/100A21/DL/SW/1/48
120 48
Soft White Double Life
3-Way
C, CC-8
2400
270lm
860lm
1130lm
3.38
5.31
19380
30/100A21/DL/SW/RP
120 12
Soft White Double Life
3-way
C, CC-8
2400
270lm
860lm
1130lm
3.38
5.31
19345
118
32
B10
Candelabra
13737
32B10C/CRYSTAL/DL/BL/2PK
120 12
Double Life Crystal
Bent Tip
C, C-7A
4000
40
A15
Med
10023
40A15/CL/DL/FAN/BL/2/24
120 24
Clear Double Life
Ceiling Fan Light
C, C-9
2000
For more complete product information visit www.sylvania.com
8
Pkg
Volts Qty
|
|
|
3.88
350
2.38
3.50
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:57 AM
A15
Page 9
A19
B10
B13
G25
R20
A21
DOUBLE LIFE LAMPS
Lasts 2X longer than ordinary Soft White lamps
34
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
40
Med
10046
40A15/CL/DL/FAN
120 24
Clear Double Life Fan
Light
C, C-9
2000
350
2.38
3.50
10133
40A15/CL/DL/BL
120 12
Clear Double Life
Appliance
C, C-9
2000
350
2.38
3.50
11664
40A15/DL/SW/BL/2/24
120 24
Soft White Double Life
Fan
C, C-9
2000
310
2.38
3.50
11646
40A/CL/DL/2PK/RP
120 24
Clear Double Life
C, CC-8
3000
385
3.13
4.44
10939
40A/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
3000
390
3.13
4.44
11645
40A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
3000
390
3.13
4.44
13328
40B10C/DL/BL/4PK
120 24
Clear Double Life Decor
Bent Tip
C, C-7A
3000
3.88
13319
40B10C/DL/BL/2PK
120 12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13714
40B10C/CRYSTAL/DL/BL/4/24 120 24
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13741
40B10C/CRYSTAL/DL/BL/2PK
120 12
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13309
40B10C/DL/F/BL/4PK
120 24
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13320
40B10C/DL/F/BL/2PK
120 12
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
A15
A19
B10
Med
Candelabra
Med
B13
G25
Med
Med
Description
13321
94
40B10/DL/BL/2PK
120 12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
13723
94
40B10/CRYSTAL/DL/BL/4PK
120 24
Double Life Crystal
Bent Tip
C, C-7A
3000
3.81
13740
94
40B10/CRYSTAL/DL/BL/2PK
120 12
Double Life Crystal
Bent Tip
C, C-7A
3000
3.81
13322
94
40B10/DL/F/BL/2PK
120 12
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.81
13366
40B13/DL/FAN/2/60/BL
120 60
Clear Double Life
Ceiling Fan
C, C-9
3000
455
4.63
13369
40B13/DL/FAN/BL/2PK
120 12
Clear Double Life
Ceiling Fan
C, C-9
3000
455
4.63
14174
40G25/DL/1/48
120 48
Clear Double Life Globe
C, C-9
3000
4.44
14147
40G25/DL/RP
120 6
Clear Double Life Globe
C, C-9
3000
4.44
14148
40G25/DL/SW/RP
120 6
Soft White Double Life
Globe
C, C-9
3000
4.44
45R20/DL/RP
120 6
Double Life Reflector
Flood
C, C-9
4000
260
45
R20
Med Brass
15698
50
100
150
A21
3CONTACT
Med
18168
50150A21DL/SW/1/48
120 48
Soft White Double Life
3-way
C, CC-8
2400
540lm
1400lm
1940lm
3.38
5.31
18044
50/150A21/DL/SW/RP
120 12
Soft White Double Life
3-way
C, CC-8
2400
540lm
1400lm
1940lm
3.38
5.31
50
R20
Med Brass
2,46,68,155
3.94
15346
2,46,68,107,155
50R20/DL/1/48
120 48
Double Life Reflector
Flood
C, C-9
4000
290
3.94
14943
2,46,68,107,155
50R20/DL/RP
120 6
Double Life Reflector
Flood
C, C-9
4000
290
3.94
For more complete product information visit www.sylvania.com
I
N
C
A
N
D
E
S
C
E
N
T
|
|
|
Symbols/Footnotes on page 35-39
9
010_INC_F.qxd
11/29/07
A15
7:57 AM
A19
Page 10
B10
B13
G25
BR30, BR40
DOUBLE LIFE LAMPS
Lasts 2X longer than ordinary Soft White lamps
I
N
C
A
N
D
E
S
C
E
N
T
34
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
60
Med
10024
60A15/CL/DL/FAN/BL/2/24
120 24
Clear Double Life Fan
Light
C, C-9
2000
530
2.38
3.50
10048
60A15/CL/DL/FAN/RP
120 24
Clear Double Life Fan
Light
C, C-9
2000
530
2.38
3.50
10868
60A15/DL/SW/BL/2/24
120 24
Soft White Double Life
Fan Light
C, C-9
2000
510
2.38
3.50
11260
60A/CL/DL/RP
120 24
Clear Double Life
C, CC-8
2000
790
3.13
4.44
11204
60A/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
2000
770
3.13
4.44
11227
60A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
2000
770
3.13
4.44
13705
60B10C/DL/BL/4PK
120 24
Clear Double Life Decor
Bent Tip
C, C-7A
3000
3.88
13777
60B10C/DL/BL/2PK
120 12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13749
60B10C/CRYSTAL/DL/BL/4/24 120 24
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13754
60B10C/DL/F/BL/4PK
120 24
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13778
60B10C/DL/F/BL/2PK
120 12
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13323
60B10/DL/BL/2PK
120 12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
13324
60B10/DL/F/BL/2PK
120 12
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.81
13370
60B13/DL/FAN/BL/2PK
120 12
Clear Double Life Fan
Lamp
C, C-9
3000
A15
A19
B10
Med
Candelabra
Med
65
75
B13
Med
G25
Med
BR30 Med Brass
650
14106
60G25/DL/RP/48
120 48
Clear Double Life Globe
C, C-9
3000
4.44
60G25/DL/RP
120 6
Clear Double Life Globe
C, C-9
3000
4.44
14104
60G25/DL/SW/RP/48
120 48
Soft White Double Life
Globe
C, C-9
3000
4.44
14150
60G25/DL/SW/RP
120 6
Soft White Double Life
Globe
C, C-9
3000
4.44
15266
65BR30/DL/2/24
120 24
Double Life Reflector
Flood
C, CC-6
4000
510
5.38
2,46,57,155
65BR30/DL/FL/RP
120 6
Double Life Reflector
Flood
C, CC-6
4000
510
5.38
BR40 Med Brass
15332
46,57,155
65BR/DL/FL/RP
120 6
Double Life Reflector
Flood
C, CC-6
4000
510
6.50
A19
11175
75A/CL/DL/RP
120 24
Clear Double Life
C, CC-8
1500
1085
3.13
4.44
11331
75A/W/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
1500
1055
3.13
4.44
11337
75A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
1500
1055
3.13
4.44
Med
A19
Med
15213
46,57,107,155
75BR40/DL/FL/1/24
120 24
Double Life Reflector
Flood
C, CC-6
4000
610
6.50
15144
46,57,107,155
75BR/DL/FL/RP
120 6
Double Life Reflector
Flood
C, CC-6
4000
610
6.50
100A/CL/DL/RP
120 24
Clear Double Life
C, CC-8
1500
1550
3.13
4.44
11660
100A/CL/DL/PLUS/2PK/RP
120 24
Clear Double Life
C, CC-8
1500
1590
3.13
4.44
16868
100A/DL/SW/PLUS/4PK/RP/160 120 160
Soft White Double Life
C, CC-8
1500
1560
3.13
4.44
16864
100A/DL/SW/PLUS/4PK/RP
Soft White Double Life
C, CC-8
1500
1560
3.13
4.44
11176
108
120 48
|
|
|
4.63
14149
For more complete product information visit www.sylvania.com
10
Description
15177
BR40 Med Brass
100
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
A19
7:57 AM
Page 11
BR40
S6
C7 Candelabra
S14
S11
DOUBLE LIFE LAMPS
Lasts 2X longer than ordinary Soft White lamps
34
Watts Bulb
Base
100
Med
A19
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
Description
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
11332
100A/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
1500
1530
3.13
4.44
100A/DL/SW/PLUS/2PK/RP
120 24
Soft White Double Life
C, CC-8
1500
1560
3.13
4.44
100A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
1500
1530
3.13
120BR/DL/FL/RP
120 6
Double Life Reflector
Flood
C, CC-6
4000
960
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
108
12480
120
BR40 Med Brass
12805
108
14915
2,46,57,107,
155
MOL
(in)
|
|
|
4.44
6.50
GENERAL PURPOSE LAMPS
34
Watts Bulb
Base
3
Candelabra
S6
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
Description
Class &
Filament
16757
3S6/5
120 240
Clear Indicator
B, C-7A
3000
10
1.44
1.88
3S6/5
130 240
Clear Indicator
B, C-7A
3000
12
1.44
1.88
16759
4
6
C7
S6
Candelabra
Candelabra
DC Bayonet
7
7.5
S14
Med Brass
C7
Candelabra
S11
Med
138
13523
4C7/DL/BL/4PK
120 48
Double Life Night Light
B, C-9
6000
14
2.13
13549
4C7/BL/4PK
120 48
Clear Night Light
B, C-9
3000
16
2.13
13542
4C7/BL/2PK
120 24
Clear Night Light
B, C-9
3000
16
2.13
13553
4C7/W/BL/4PK
120 48
White Night Light
B, C-7
3000
16
2.13
13538
4C7/W/BL/2PK
120 24
White Night Light
B, C-9
3000
16
2.13
13556
4C7/BLUE/2PK
120 24
Blue Nightlight
B, C-7A
3000
13557
4C7/PINK/2PK
120 24
Pink Nightlight
B, C-7A
3000
16927
6S6/CL12V
12
120
Clear Indicator
B, C-2R
1500
47
1.44
1.88
16929
6S6/CL24V
24
120
Clear Indicator
B, C-7A
1500
48
1.44
1.88
16930
6S6/CL30V
30
120
Clear Casino
B, C-7A
1500
46
1.44
1.88
16960
6S6/CL
120 120
Clear Indicator
B, C-7A
1500
41
1.44
1.88
16938
6S6/CL
130 120
Clear Indicator
B, C-7A
1500
37
1.44
1.88
16942
6S6/CL145V
145 120
Clear Indicator
B, C-7A
1500
33
1.44
1.88
16943
6S6/CL155V
155 120
Clear Indicator
B, C-7A
1500
36
1.44
1.88
16782
6S6DC
120 120
Clear Indicator
B, C-9
1500
41
1.44
1.81
16784
6S6DC
130 120
Clear Indicator
B, C-9
1500
37
1.44
1.81
16790
6S6DC145V
145 120
Clear Indicator
B, C-9
1500
37
1.44
1.72
17314
6S14
120 120
Clear
B, C-9
1500
40
2.50
3.50
2.13
2.13
13608
7C7
120 120
Clear Night Light
B, C-9
3000
43
2.13
13545
7C7/BL/4PK
120 48
Clear Night Light
B, C-9
3000
43
2.13
13543
7C7/BL/2PK
120 24
Clear Night Light
B, C-9
3000
43
2.13
13609
7C7
130 120
Clear Night Light
B, C-9
3000
42
2.13
13623
7C7/CW
120 120
White Night Light
B, C-9
3000
33
2.13
13544
7C7/W/BL/4PK
120 48
White Night Light
B, C-9
3000
33
2.13
13540
7C7/W/BL/2PK
120 24
White Night Light
B, C-9
3000
33
19353
7.5S
120 120
Clear
B, C-9
1400
47
1.56
2.25
19355
7.5S
130 120
Clear
B, C-9
1400
45
1.56
2.25
19420
7.5S/CW
120 120
Ceramic White
B, C-9
1400
32
2.25
19433
7.5S/CW/BL
120 12
Ceramic White Utility
Light
B, C-9
1400
32
2.25
19421
7.5S/CW/BL/1/6
120 6
Ceramic White Utility
Light
B, C-9
1400
32
2.25
For more complete product information visit www.sylvania.com
|
|
|
2.13
Symbols/Footnotes on page 35-39
11
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
S11
7:57 AM
Page 12
C7 Candelabra
S6
S14
A15
A21
T6
T7
T10
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Description
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
120 120
Ceramic Red
B, C-9
1400
2.25
10C7/CL
120 240
Clear Pilot Light
Vibration Resistant
B, C-7A
10S6
120 240
Clear Indicator
B, C-7A
1500
71
1.44
1.88
10S6230V
230 240
Clear Indicator
B, CC-7A
1500
65
1.44
1.88
16917
10S11N/CL
120 120
Clear Vibration
Resistant
B, C-7A
1500
74
1.63
2.31
16919
10S11N/CL
130 120
Clear Vibration
Resistant
B, C-7A
1500
74
1.63
2.31
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
7.5
S11
Med
19423
10
C7
Candelabra
13636
S6
Candelabra
1
16726
16717
S11
11
Intermediate
138
Pkg
Volts Qty
7.5S/CR
38
2.13
S14
Med Brass
17406
10S14
120 120
Clear Vibration
Resistant
B, C-9
1500
76
2.50
3.50
S14
Med Brass
17448
11S14
120 120
Clear Vibration
Resistant
B, C-9
3000
74
2.50
3.50
17450
11S14
130 120
Clear Vibration
Resistant
B, C-9
3000
72
2.50
3.50
17453
11S14/IF
130 120
Inside Frost Vibration
Resistant
B, C-9
3000
68
2.50
3.50
17487
11S14/TR
130 120
Transparent Red
B, C-9
3000
2.50
3.50
12
S6
Candelabra
16718
12S6/250V
250 240
Clear Indicator
B, CC-7A
1500
61
1.44
1.88
15
A15
Med
10015
15A15/W/RP
120 24
White Utility Light
C, C-9
2500
65
2.38
3.50
10018
15A15/CL
120 120
Clear Utility Light
B, C-9
2500
105
2.38
3.50
10028
15A15/CL/RP
120 24
Clear Utility Light
B, C-9
2500
105
2.38
3.50
10019
15A15/CL
130 120
@ 120 _volts, approximate 13 watts, 80 lumens, 6250 hours.
Clear Utility Light
B, C-9
2500
105
2.38
3.50
10037
15A15
120 120
Inside Frost
B, C-9
2500
100
2.38
3.50
10031
15A15/RP
120 24
Inside Frost
B, C-9
2500
100
2.38
3.50
10038
15A15
130 120
@ 120 _volts, approximate 13 watts, 76 lumens, 6250 hours.
Inside Frost
B, C-9
2500
100
2.38
3.50
15
135
150
A21
3 CONTACT
Med
18009
15/150A/SECURITYLIGHT
120 12
Soft White Security
3-way
C, CC-8
1200
800m
2070lm
2150lm
3.38
5.31
15
S11
Med
17079
15S11/102/IF
120 120
Inside Frost
Refrigerator
B, C-7A
400
138
1.56
2.25
S14
Med Brass
17240
15S14/CL
130 120
Clear Vibration
Resistant Sign
B, C-9
3000
106
2.50
3.50
T6
Candelabra
T7
18037
15T6
120 60
Clear Tubular
B, C-7A
2000
111
3.06
18038
15T6
130 60
Clear Tubular
B, C-7A
2000
105
3.06
18078
15T6/145V
145 60
Clear Tubular
B, C-7A
2000
112
3.06
18036
15T6/BL
145 12
Clear Tubular
B, C-7A
2000
112
3.06
Candelabra
18185
15T7C
120 60
Clear
B, C-7A
1000
111
1.50
2.25
DC Bayonet
18208
111
15T7DC
120 60
Clear
B, C-7A
1000
111
1.31
2.25
18200
111
15T7DC/BL
120 12
Clear Carded
B, C-7A
1000
111
1.31
2.25
18201
111
15T7DC/BL/1/6
120 6
Clear Carded
B, C-7A
1000
111
1.31
2.25
18173
111
15T7N
120 60
Clear
B, C-7A
1000
115
1.56
2.25
15T7N/BL
120 12
Clear
B, C-7A
1000
115
1.56
2.25
15T10/CL
120 60
Clear Tubular
B, C-8
2500
112
Intermediate
18174
T10
Med
18501
138
For more complete product information visit www.sylvania.com
12
|
|
|
5.63
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:57 AM
T6.5
Page 13
A19
R14 Inter
R14
T8
T10
GENERAL PURPOSE LAMPS
34
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
10000
5.56
Watts Bulb
Base
20
T6.5
DC Bayonet
18144
1
20T6.5DC/IF
120 60
Inside Frost Exit Lamp
B, C-8
Intermediate
18143
1
20T6.5/IF
120 60
Inside Frost Exit Lamp
B, C-8
10000
92
25
A19
Med
11090
25A/RS
120 120
Inside Frost Rough
Service
B, C-17
1000
210
2.50
3.94
11092
25A/RS
130 120
Inside Frost Rough
Service
B, C-17
1000
210
2.50
3.94
10562
25A/W/RP
120 24
Soft White
C, C-9
2500
160
2.50
3.94
10644
25A
120 120
Standard Frost
B, C-9
2500
190
2.50
3.94
10634
25A/RP
120 24
Med Brass
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
T6.5
Intermediate
Standard Frost
B, C-9
2500
190
2.50
3.94
Standard Frost
B, C-9
2500
180
2.50
3.94
11285
25A
230 120
Standard Frost
B, C-17
1000
205
2.50
3.94
11289
25A
277 120
Standard Frost
B, C-17
1000
187
2.50
3.94
10693
25A/CL
120 120
Clear
B, C-9
2500
190
2.50
3.94
10683
25A/CL/RP
120 24
Clear
B, C-9
2500
190
2.50
3.94
Clear
B, C-9
2500
180
2.50
3.94
11710
25A19/TB/RP
125 6
Transparent Blue
B, C-9
3000
2.50
3.94
11714
25A19/TG/RP
125 6
Transparent Green
B, C-9
3000
2.50
3.94
11711
25A19/TO/RP
125 6
Transparent Orange
B, C-9
3000
2.50
3.94
11712
25A19/TR/RP
125 6
Transparent Red
B, C-9
3000
2.50
3.94
11713
25A19/TY/RP
125 6
Transparent Yellow
B, C-9
3000
2.50
3.94
10449
25A
12
Standard Frost
B, C-6
1000
2.50
3.94
385
14793
25R14N
120 60
Reflector Mini Flood
B, CC-2V
1500
132
2.56
25R14N/RP
120 6
Reflector Mini Flood
B, CC-2V
1500
132
2.56
Med
14818
25R14/RP
120 6
Reflector Mini Flood
C, CC-2V
1500
132
2.25
DC Bayonet
18129
25T6.5/DC
120 60
Clear Scale Illuminator
B, C-8
1000
242
5.56
18106
25T6.5/DC
130 60
Clear Scale Illuminator
B, C-8
1000
242
5.56
18117
25T6.5/DC/IF
120 60
Inside Frost Scale
Illuminator
B, C-8
1000
225
5.56
18125
25T6.5
120 60
Clear
B, C-8
1000
242
5.50
18496
25T6.5/CL/BL/10PK
120 10
Clear
B, C-8
1000
242
5.50
18495
25T6.5/BL/6PK
120 6
Clear
B, C-8
1000
242
5.50
18128
25T6.5
130 60
Clear
B, C-8
1000
242
5.50
18113
25T6.5/IF
120 60
Inside Frost
B, C-8
1000
225
5.50
25T6.5/IF
130 60
Inside Frost
B, C-8
1000
225
25T8C
120 60
Clear Home Appliance
B, C-7A
1000
230
18111
Candelabra
DC Bayonet
Intermediate
T10
120
14784
Intermediate
T8
5.50
10645
136,146
25A
130 120
@120 _volts, approximate 22 watts, 130 lumens, 6250 hours
10694 136,146
25A/CL
130 120
@120 _volts, approximate 22 watts, 130 lumens, 6250 hours
R14
92
Med
18289
111
5.50
1.50
2.63
18310
111
25T8DC
120 60
Clear Home Appliance
B, C-7A
1000
230
1.31
2.63
18321
111
25T8DC/BL
120 12
Clear Home Appliance
B, C-7A
1000
230
1.31
2.63
18316
111
25T8DC
130 60
Clear Home Appliance
B, C-7A
1000
215
1.31
2.63
18359
111
25T8N
120 60
Clear Home Appliance
B, C-7A
1000
230
1.31
2.63
18365
111
25T8N/BL
120 12
Clear Home Appliance
B, C-7A
1000
230
1.31
2.63
18360
111
25T8N/BL/1/6
120 6
Clear Home Appliance
B, C-7A
1000
230
1.31
2.63
25T10
120 60
Clear
B, C-8
1000
232
18510
For more complete product information visit www.sylvania.com
|
|
|
5.63
Symbols/Footnotes on page 35-39
13
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
T10
7:57 AM
Page 14
A15
A21
R20
S11
A19
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
25
Med
18491
25T10/CL/BL/6PK
120 6
Clear
B, C-8
1000
232
5.63
18512
25T10
130 60
Clear
B, C-8
1000
232
5.63
18503
25T10/IF
120 60
Inside Frost
B, C-8
1000
230
5.63
18492
25T10/IF/BL/6PK
120 6
Inside Frost
B, C-8
1000
230
5.63
18505
25T10/IF
130 60
Inside Frost
B, C-8
1000
230
5.63
T10
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
30
A15
Med Brass
10122 77
30A15
130 120
@ 120 _volts, approximate 26 watts, 150 lumens, 5000 hours.
Inside Frost
C, C-9
2000
200
2.38
3.50
30
70
100
A21
3 CONTACT
Med
19395
19345
118
19380
30
R20
Med Brass
30/100/DAYLIGHT/1/12
120 12
Daylight 3-Way
C, CC-8
1200
220lm
700lm
920lm
3.38
5.31
30/100A21/DL/SW/1/48
120 48
Soft White Double Life
3-Way
C, CC-8
2400
270lm
860lm
1130lm
3.38
5.31
30/100A21/DL/SW/RP
120 12
Soft White Double Life
3-way
C, CC-8
2400
270lm
860lm
1130lm
3.38
5.31
18029
118
30/100A/W/DIYPACK
120 48
Soft White 3-way
C, CC-8
1200
300lm
945lm
1245lm
3.38
5.31
19385
118
30/100A21/W/RP
120 12
Soft White 3-way
C, CC-8
1200
300lm
945lm
1245lm
3.38
5.31
14794
68,118
30R20
120 60
Reflector Flood
C, C-9
2000
140
40˚
3.94
14836
68,118
30R20/RP
120 6
Reflector Flood
C, C-9
2000
140
40˚
3.94
14802
136,147
30R20
130 60
Reflector Flood
C, C-9
2000
140
40˚
3.94
Clear Train Marker
C, C-7A
500
284
1.50
2.38
Clear Street Lighting
Group Replacement
C, C-9
3000
258
2.88
4.25
|
|
|
@ 120 _volts, approximate 26 watts, 100 lumens, 5000 hours
32
S11
DC Bayonet
10765
A19
Med Brass
10983
79
30S11/DC/75V
75
120
32A19/49
130 120
@ 120 _volts, approximate 28 watts, 200 lumens, 7500 hours.
34
A19
Med
11391
40A/34/W/ES/4PK
120 48
Soft White Energy Saver
C, CC-8
1500
375
3.13
4.44
11058
40A/34/SS
120 48
Standard Frost
SuperSaver
C, CC-8
1500
375
3.13
4.44
40A/34/SS
130 48
Standard Frost
SuperSaver
C, CC-8
1500
380
3.13
4.44
11379
136,150
@ 120 _volts, approximate 30 watts, 290 lumens, 3750 hours
Med Brass
11383
11387
136,149
40A/34/SS/XL
120 48
Standard Frost
SuperSaver XL
C, CC-8
2500
310
3.13
4.44
40A/34/SS/XL
130 48
Standard Frost
SuperSaver XL
C, CC-8
2500
310
3.13
4.44
@ 120 _volts, approximate 30 watts, 240 lumens, 6250 hours
40
A15
Candelabra
Med
11534
40A15C/SW/FAN/2/12/BL
120 12
Soft White Ceiling Fan
Light
C, C-9
1000
300
1.94
3.38
10029
40A15C/CL/FAN/2/12/BL
120 12
Clear Ceiling Fan
C, C-9
1000
330
1.94
3.38
10181
40A15/DAY/FAN/BL/2/24
120 24
Daylight Fan
C, C-9
1000
340
2.38
3.50
11664
40A15/DL/SW/FAN/BL/2/24
120 24
Soft White Double Life
Fan
C, C-9
2000
310
2.38
3.50
10061
40A15/CL/DL/APPL/2/12/BL
120 12
Clear Double Life
Appliance
C, C-9
2000
350
2.38
3.50
For more complete product information visit www.sylvania.com
14
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:57 AM
A15
Page 15
A19
K19
R14 Inter
GENERAL PURPOSE LAMPS
34
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
40
Med
10023
40A15/CL/DL/FAN/BL/2/24
120 24
Clear Double Life
Ceiling Fan Light
C, C-9
2000
350
2.38
3.50
10046
40A15/CL/DL/FAN
120 24
Clear Double Life Fan
Light
C, C-9
2000
350
2.38
3.50
10034
40A15/CL/DL/FAN/2/12/BL
120 12
Clear Double Life Fan
Light
C, C-9
2000
350
2.38
3.50
10133
40A15/CL/DL/BL
120 12
Clear Double Life
Appliance
C, C-9
2000
350
2.38
3.50
10082
40A15/SL
120 120
Safeline Appliance
C, C-9
1000
420
2.38
3.50
11111
40A15/SW/FAN/BL/2/24
120 24
Soft White Ceiling Fan
Light
C, C-9
1000
405
2.38
3.50
11533
40A15/SW/FAN/2/12/BL
120 12
Soft White Ceiling Fan
C, C-9
1000
405
2.38
3.50
10042
40A15/CL/FAN
120 24
Clear Ceiling Fan Light
C, C-9
1000
430
2.38
3.50
10022
40A15/CL/FAN/BL/2/24
120 24
Clear Ceiling Fan Light
C, C-9
1000
430
2.38
3.50
10036
40A15/CL/FAN/2/12/BL
120 12
Clear Ceiling Fan Light
C, C-9
1000
420
2.38
3.50
10141
40A15/2PK/RP
120 24
Clear Appliance
C, C-9
1000
430
2.38
3.50
10169
40A15/CL/BL/2/24
120 24
Clear Appliance
C, C-9
1000
430
2.38
3.50
10066
40A15/CL/APPL/2/12/BL
120 12
Clear Appliance
C, C-9
1000
420
2.38
3.50
10129
40A15/CL/BL
120 12
Clear Appliance
C, C-9
1000
430
2.38
3.50
10119
40A15
120 120
Inside Frost Appliance
C, C-9
1000
420
2.38
3.50
10117
40A15/IF/BL
120 12
Inside Frost Appliance
C, C-9
1000
420
2.38
3.50
A15
Med Brass
A19
Med
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
Description
10365
40A15/1
250 120
Inside Frost Appliance
B, C-9
1000
330
2.50
3.50
10370
40A15/NEO
250 120
Neodymium Doped
Appliance Lamp
B, C-9
1000
320
2.50
3.50
10897
40A/DAY/4/160/RP
120 160
Daylight
C, CC-8
1500
350
3.13
4.44
10864
40A/DAY/RP/4/48
120 48
Daylight
C, CC-8
1500
350
3.13
4.44
11100
40A/DAY/RP/2/24
120 24
Daylight
C, CC-8
1500
350
3.13
4.44
10829
99,136
40A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 33 watts, 270 lumens, 3750 hours.
Daylight
C, CC-8
1500
350
3.13
4.44
10939
40A/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
3000
390
3.13
4.44
11645
40A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
3000
390
3.13
4.44
11646
40AC/DL/2PK/RP
120 24
Clear Double Life
C, CC-8
3000
385
3.13
4.44
10996
40A/W/4/RP
120 48
Soft White
C, CC-8
1500
465
3.13
4.44
10977
40A/W/RP
120 24
Soft White
C, CC-8
1500
465
3.13
4.44
11223
40A/CL/RP
120 24
Clear
C, CC-8
1500
480
3.13
4.44
11036
136,153 40A/CL
130 120
@ 120 _volts, approximate 35 watts, 350 lumens, 3750 hours
Clear
C, CC-8
1500
460
3.13
4.44
11060
40A/4/RP
120 48
Standard Frost
C, CC-8
1500
470
3.13
4.44
11010
40A/RP
120 24
Standard Frost
C, CC-8
1500
470
3.13
4.44
11059
136,153 40A
130 48
@ 120 _volts, approximate 35 watts, 350 lumens, 3750 hours
Standard Frost
C, CC-8
1500
460
3.13
4.44
11011
136,153 40A/CVP
130 24
@ 120 _volts, approximate 35 watts, 350 lumens, 3750 hours
Standard Frost
C, CC-8
1500
460
3.13
4.44
385
K19
Med
10471
40K19/DR
120 24
Inside Frost
Directional Reflector
C, CC-6
1150
R14
Intermediate
14820
40R14N/RP
120 6
Reflector Mini Flood
C, CC-2V
1500
For more complete product information visit www.sylvania.com
|
|
|
4.13
2.56
Symbols/Footnotes on page 35-39
15
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
R14
7:57 AM
R16
Page 16
S11
T6.5
T8
T10
A21
BR30
R20
A19
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
2.25
Watts Bulb
Base
40
R14
Med
14819
40R14/RP
120 6
Reflector Mini Flood
C, C-9
1500
R16
Med
14821
40R16/FL/RP
120 6
Reflector Mini Flood
C, C-9
1500
S11
Intermediate
13595
40S11N
120 120
Clear Hi Intensity
C, C-7A
500
440
1.63
2.31
13607
40S11N/BL
120 12
Clear Hi Intensity
C, C-7A
500
440
1.63
2.31
13644
40S11N/BL/2/12
120 12
Clear Hi Intensity
C, C-7A
500
440
1.63
2.31
13640
40S11N/NEO/BULK
120 6000 Neodymium doped Hi
Intensity
C, C-7A
500
1.63
2.31
T6.5
Intermediate
T8
Intermediate
T10
Med
45
95
140
A21
3 CONTACT
Med
45
BR30 Med
18096
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
Med
3.88
40T6.5/2
120 60
Clear Appliance
C, C-8
1000
365
5.50
18497
40T6.5/CL/BL/10PK
120 10
Clear Appliance
C, C-8
1000
365
5.50
18152
40T6.5/CL/BL/6PK
120 6
Clear Appliance
C, C-8
1000
365
18358
40T8N/NEODYMIUM
120 6000 Neodymium Doped
Appliance
B, C-7A
1000
300
130
5.50
1.31
2.63
18650
40T10
120 60
Clear
B, C-8
1000
420
5.63
18493
40T10/CL/BL/6PK
120 6
Clear
B, C-8
1000
420
5.63
18652
40T10
130 60
Clear
B, C-8
1000
420
5.63
18494
40T10/IF/BL/6PK
120 6
Inside Frost
B, C-8
1000
415
5.63
18669
40T10/IF
130 60
Inside Frost
B, C-8
1000
415
18048
45/140A21/W/ES/RP
120 12
Soft White 3-way Energy
Saver
C, CC-8
1200
540lm
1300lm
1840lm
45BR30/FL/RP
120 6
Reflector Flood
C, CC-6
2000
350lm
170 cd
60˚
5.38
15103
2,46,57,
155
R20
185
5.63
3.38
5.31
15677
2,46,68,155
45R20/DAY/1/6/RP
120 6
Daylight Reflector
C, C-9
2000
215lm
360 cd
45˚
3.94
15697
2,46,68,155
45R20
120 60
Reflector Flood
C, C-9
2000
295lm
490 cd
45˚
3.94
14997
2,46,68,155
45R20/RP/2/12
120 12
Reflector Flood
C, C-9
2000
295lm
490 cd
45˚
3.94
15670
2,46,68,155
45R20/RP
120 6
Reflector Flood
C, C-9
2000
295lm
490 cd
45˚
3.94
2,46,68,105,
45R20
130 60
Reflector Flood
C, C-9
2000
490 cd
45˚
3.94
Reflector Flood
C, C-9
2000
490 cd
45˚
3.94
3.94
15699
136,155
|
|
|
@ 120 _volts, approximate 40 watts, 220 lumens, 5000 hours.
15676
2,46,68,105,
45R20/CVP
130 6
136,155
@ 120 _volts, approximate 40 watts, 220 lumens, 5000 hours.
50
A19
Med Brass
15698
45R20/DL/RP
120 6
Double Life Reflector
Flood
C, C-9
4000
260
430 cd
45˚
Med
11096
50A/RS/4/144/RP
120 144
Inside Frost Rough
Service
C
1000
510
14070
50A/RS/2/RP
120 24
Inside Frost Rough
Service
C
1000
510
11393
50A/RS
250 120
Inside Frost Rough
Service
C, C-22
1000
450
2,46,68,155
For more complete product information visit www.sylvania.com
16
2.50
4.44
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:57 AM
A19
Page 17
A21
ER30
R20
GENERAL PURPOSE LAMPS
34
Description
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
250 120
Inside Frost
B, CC-7A
1000
490
2.50
4.44
50A
277 120
Inside Frost
B, CC-7A
1000
475
2.50
4.44
50A/RS/SL
120 120
Safeline Rough Service
C, C-9
1000
490
2.50
3.94
50A19/RS
75
Inside Frost Rough
Service Train
C, C-9
1000
505
2.50
3.94
18110
50/150/DAY/1/12
120 12
Daylight 3-way
C, CC-8
1200
460lm
1170lm
1630lm
3.38
5.31
18168
50/150A21DL/SW/1/48
120 48
Soft White Double Life
3-way
C, CC-8
2400
540lm
1400lm
1940lm
3.38
5.31
18044
50/150A21/DL/SW/RP
120 12
Soft White Double Life
3-way
C, CC-8
2400
540lm
1400lm
1940lm
3.38
5.31
18457
50/150A21/W/2/48
120 48
Soft White 3-Way
C, CC-8
1200
640lm
1570lm
2210lm
3.38
5.31
18028
50/150A/W/DIYPACK
120 48
Soft White 3-way
C, CC-8
1200
640lm
1570lm
2210lm
3.38
5.31
18458
50/150A21/W/2PK/12
120 12
Soft White 3-Way
C, CC-8
1200
640lm
1570lm
2210lm
3.38
5.31
18060
50/150A21/W/RP
120 12
Soft White 3-way
C, CC-8
1200
640lm
1570lm
2210lm
3.38
5.31
18726
50/150A21/SPK/RP
120 12
Soft Pink 3-way
C, CC-8
1200
3.38
5.31
19404
50/250A21/W/RP
120 12
Soft White Reading
Light 3-way
C, CC-8
1200
640lm
3300lm
3940lm
3.38
5.31
11572
50A21
12
24
Inside Frost RV-Marine
C, C-6
1000
865
3.88
4.94
11567
50A21/RP
12
12
Inside Frost RV-Marine
C, C-6
1000
865
3.88
4.94
11603
50A21
34
12
Inside Frost Train
C, C-9
1000
800
3.44
4.94
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
50
Med
11397
A19
11428
Med Brass
11118
11068
50
100
150
50
A21
A21
ER30
3 CONTACT
Med
Med Brass
Med
116
133
Pkg
Volts Qty
50A
120
15102
2,155
50ER30
120 24
Elliptical Reflector
Flood
C, CC-6
2000
350lm
800 cd
30˚
6.38
15110
2,155
50ER30/RP
120 6
Elliptical Reflector
Flood
C, CC-6
2000
350lm
800 cd
30˚
6.38
15107
2,136,155,159
50ER30
130 24
Elliptical Reflector
Flood
C, CC-6
2000
320lm
730 cd
30˚
6.38
|
|
|
@ 120 _volts, approximate 44 watts, 240 lumens, 5000 hours
R20
Med
15231
2,46,68,107,
50R20/DAY/1/6/RP
120 6
Daylight Reflector
C, C-9
2000
240lm
400 cd
45˚
3.94
50R20
120 60
Reflector Flood
C, C-9
2000
330lm
550 cd
45˚
3.94
50R20/2PK
120 48
Reflector Flood
C, C-9
2000
330lm
550 cd
45˚
3.94
50R20/RP/2/12
120 12
Reflector Flood
C, C-9
2000
330lm
550 cd
45˚
3.94
155
14831
2,46,68,107,
155
14914
2,46,68,107,
155
14998
107
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 35-39
17
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
R20
7:57 AM
Page 18
A19
A15
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
50
Med
14833
R20
2,46,68,107,
Description
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
120 6
Reflector Flood
C, C-9
2000
330lm
550 cd
45˚
3.94
130 60
Reflector Flood
C, C-9
2000
330lm
550 cd
45˚
3.94
Reflector Flood
C, C-9
2000
330lm
550 cd
45˚
3.94
Pkg
Volts Qty
50R20/RP
50R20
155
14832
2,46,68,107,
136,155,158
|
|
|
@ 120 _volts, approximate 44 watts, 250 lumens, 5000 hours
14844
2,46,68,107,
50R20/CVP
130 6
136,155,158
@ 120 _volts, approximate 44 watts, 250 lumens, 5000 hours
14846
2,46,68,136,
50R20/PINK
130 60
Pink Reflector
C, C-9
2000
420lm
3.94
155
Med Brass
52
A19
Med
15346
2,46,68,107,155
50R20/DL/1/48
120 48
Double Life Reflector
Flood
C, C-9
4000
290lm
480 cd
45˚
3.94
14943
2,46,68,107,155
50R20/DL/RP
120 6
Double Life Reflector
Flood
C, C-9
4000
290lm
480 cd
45˚
3.94
14834
2,46,68,155
50R20/PINK
120 60
Pink Reflector
C, C-9
2000
3.94
14842
2,46,68,155
50R20/GRO
120 6
Spot-GRO Reflector
C, C-9
2000
3.94
60A/52/W/ES/4PK
120 48
11392
Soft White Energy Saver
C, CC-8
1000
715
3.13
4.44
10893
104,136 60A/52/CL/SS
130 48
@ 120 _volts, approximate 46 watts, 560 lumens, 2500 hours.
Clear SuperSaver
C, CC-8
1000
740
3.13
4.44
11376
11380
136,164
60A/52/SS
120 48
Standard Frost
SuperSaver
C, CC-8
1000
750
3.13
4.44
60A/52/SS
130 48
Standard Frost
SuperSaver
C, CC-8
1000
710
3.13
4.44
@ 120 _volts, approximate 46 watts, 540 lumens, 2500 hours
Med Brass
11384
120 48
Standard SuperSaver XL C, CC-8
2500
620
3.13
4.44
11388
136,163
60A/52/SS/XL
130 48
@ 120 _volts, approximate 46 watts, 460 lumens, 6250 hours
60A/52/SS/XL
Standard SuperSaver XL C, CC-8
2500
610
3.13
4.44
58
A19
Med Brass
11149
58A19/62
120 120
Clear Street Lighting
Group Replacement
C, C-9
3000
630
2.88
4.25
60
A15
Candelabra
10777
60A15C/SW/FAN/2/12/BL
120 12
Soft White Ceiling Fan
Light
C, C-9
1000
510
1.94
3.38
10894
60A15C/CL/FAN/2/12/BL
120 12
Clear Ceiling Fan Light
C, C-9
1000
560
1.94
3.38
10162
60A15/DAY/FAN/BL/2/24
120 24
Daylight Fan
C, C-9
1000
340
2.38
3.50
10868
60A15/DL/SW/BL/2/24
120 24
Soft White Double Life
Fan Light
C, C-9
2000
510
2.38
3.50
10885
60A15/SW/FAN/2/12/BL
120 12
Soft White Double Life
Fan Light
C, C-9
1000
680
2.38
3.50
10048
60A15/CL/DL/FAN/RP
120 24
Clear Double Life Fan
Light
C, C-9
2000
530
2.38
3.50
10024
60A15/CL/DL/FAN/BL/2/24
120 24
Clear Double Life Fan
Light
C, C-9
2000
530
2.38
3.50
10040
60A15/CL/DL/FAN/2/12/BL
120 12
Clear Double Life Fan
Light
C, C-9
2000
530
2.38
3.50
11005
60A15/SW/FAN/2PK
120 24
Soft White Ceiling Fan
C, C-9
1000
680
2.38
3.50
10842
60A15/SW/FAN/BL/2/24
120 24
Soft White Ceiling Fan
C, C-9
1000
680
2.38
3.50
10841
60A15/CL/FAN/BL/2/24
120 24
Clear Ceiling Fan Light
C, C-9
1000
700
2.38
3.50
Med
For more complete product information visit www.sylvania.com
18
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:57 AM
A15
Page 19
A19
GENERAL PURPOSE LAMPS
34
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
60
Med
11007
60A15/CL/FAN/RP
120 24
Clear Ceiling Fan Light
C, C-9
1000
700
2.38
3.50
10884
60A15CL/FAN/2/12/BL
120 12
Clear Ceiling Fan Light
C, C-9
1000
700
2.38
3.50
10886
60A15/GARAGE/2/12/BL
120 12
Clear Garage Light
C, C-9
1000
690
2.38
3.50
11008
60A15/GARAGE/RP
120 24
Inside Frost Garage
Door
C, C-9
1000
690
2.38
3.50
A15
Med Brass
A19
Med
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
11509
60A/DAY/4/160/RP
120 160
Daylight
C, CC-8
1000
640
3.13
4.44
11463
60A/DAY/RP/4/48
120 48
Daylight
C, CC-8
1000
640
3.13
4.44
11101
60A/DAY/RP/2/24
120 24
Daylight
C, CC-8
1000
640
3.13
4.44
11602
101,136 60A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 53 watts, 490 lumens, 2500 hours.
Daylight
C, CC-8
1000
640
3.13
4.44
11204
60A/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
2000
770
3.13
4.44
11227
60A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
2000
770
3.13
4.44
11260
60A/CL/DL/RP
120 24
Clear Double Life
C, CC-8
2000
790
3.13
4.44
10503
60A/RS/SL/RP
120 12
Safeline Rough Service
Inside Frost
C, C-9
1000
555
3.13
4.44
13000
60A/RS/2/RP
120 24
Inside Frost Rough
Service
C, C-9
1000
555
2.88
4.44
12977
60A/RS/RP/1
120 12
Inside Frost Rough
Service
C, C-9
1000
555
2.88
4.44
60A/RS/2/RP
130 24
Inside Frost Rough
Service
C, C-9
1000
555
2.88
4.44
12420
136,168
|
|
|
@ 120 _volts, approximate 53 watts, 420 lumens, 2500 hours
Med Brass
11205
60A/W/4/RP
120 48
Soft White
C, CC-8
1000
850
3.13
4.44
11208
60A/W/RP
120 24
Soft White
C, CC-8
1000
850
3.13
4.44
10553
60A/CL
120 120
Clear
C, CC-8
1000
880
3.13
4.44
11224
60A/CL/RP
120 24
Clear
C, CC-8
1000
880
3.13
4.44
10555
136,170 60A/CL
130 120
@ 120 _volts, approximate 53 watts, 650 lumens, 2500 hours
Clear
C, CC-8
1000
855
3.13
4.44
10558
170
60A/CL/CVP
130 24
@ 120 _volts, approximate 53 watts, 650 lumens, 2500 hours
Clear
C, CC-8
1000
855
3.13
4.44
11180
60A/4/RP
120 48
Standard Frost
C, CC-8
1000
870
3.13
4.44
11214
60A/RP
120 24
Standard Frost
C, CC-8
1000
870
3.13
4.44
11373
136,170 60A
130 48
@ 120 _volts, approximate 53 watts, 650 lumens, 2500 hours
Standard Frost
C, CC-8
1000
855
3.13
4.44
10489
136,170 60A/CVP
130 24
@ 120 _volts, approximate 53 watts, 650 lumens, 2500 hours
Standard Frost
C, CC-8
1000
855
3.13
4.44
11715
60A/BLACKLIGHT/RP
120 6
Blacklight
C, CC-8
1000
3.13
4.44
10390
60A/Y/RP
120 24
Yellow Bug Light
C, CC-8
1000
3.13
4.44
10386
60A/Y/RP
130 24
Yellow Bug Light
C, CC-8
1000
3.13
4.44
10576
60A/SPK
120 24
Soft Pink
C, CC-8
1000
3.13
4.44
12280
60A/GRO
120 6
Spot-GRO
C, C-9
1000
3.13
4.44
13021
60A/RS/XL
120 24
Inside Frost Rough
Service XL
C, C-9
5000
450
2.88
4.44
60A/RS/XL
130 24
Inside Frost Rough
Service XL
C, C-9
5000
450
2.88
4.44
Inside Frost Dental
Spot
C, C-9
1000
1010
3.13
4.44
12455
80
@ 120 _volts, approximate 53 watts, 340 lumens, 12500 hours.
10640
60A
For more complete product information visit www.sylvania.com
24
120
Symbols/Footnotes on page 35-39
19
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
C15
7:57 AM
K19
Page 20
T10
BR30
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
60
C15
Med Brass
14200
60C15/FAN/2PK
120 12
Clear Ceiling Fan Light
C, C-9
4000
528
4.50
K19
Med
10483
60K19/DR
120 24
Inside Frost
Directional Reflector
C, CC-6
1150
630
4.13
T10
Med
65
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
18710
60T10/64
120 60
Clear
C, C-8
1000
655
5.63
18712
60T1064BL
120 6
Clear
C, C-8
1000
655
5.63
18711
60T10/CF
120 60
Inside Frost Showcase
C, C-8
1000
630
5.63
S14s
19675
LN60 125-130V
125 25
Opal White LINESTRA
1605
B, C-8
1000
460
19.69
BR30 Med
15223
2,46,57,
65BR30/DAY/1/6/RP
120 6
Daylight Reflector
C, CC-6
2000
420lm
250 cd
60˚
5.38
2,46,57,
65BR30/FL/SL/RP
130 6
Reflector Safeline
Flood
C, CC-6
2000
620lm
370 cd
60˚
5.38
155
15167
155
|
|
|
@ 120 _volts, approximate 57 watts, 470 lumens, 5000 hours.
15148
2,46,57,
65BR30/TRAY
120 48
Reflector Flood
C, CC-6
2000
620lm
370 cd
60˚
5.38
2,46,57,
65BR30/FL
120 24
Reflector Flood
C, CC-6
2000
620lm
370 cd
60˚
5.38
2,46,57,
65BR30/2/24/RP
120 24
Reflector Flood
C, CC-6
2000
620lm
370 cd
60˚
5.38
2,46,57,
65BR30/FL/RP
120 6
Reflector Flood
C, CC-6
2000
620lm
370 cd
60˚
5.38
2,46,57,
65BR30/SP/RP
120 6
Reflector Spot
C, CC-6
2000
620lm
580 cd
30˚
5.38
2,46,57,
65BR30/FL
130 24
Reflector Flood
C, CC-6
2000
620lm
370 cd
60˚
5.38
Reflector Flood
C, CC-6
2000
620lm
370 cd
60˚
5.38
155
15165
155
15246
155
15160
155
15149
155
13129
155
@ 120 _volts, approximate 57 watts, 470 lumens, 5000 hours.
15172
2,46,57,
65BR30/FL/CVP
130 6
155
@ 120 _volts, approximate 57 watts, 470 lumens, 5000 hours.
15150
2,46,57,
65BR30/A/RP
120 6
Amber Reflector Flood
C, CC-6
2000
5.38
2,46,57,
65BR30/B/RP
120 6
Blue Reflector Flood
C, CC-6
2000
5.38
2,46,57,
65BR30/G/RP
120 6
Green Reflector Flood
C, CC-6
2000
5.38
2,46,57,
65BR30/PK/RP
120 6
Pink Reflector Flood
C, CC-6
2000
5.38
2,46,57,
65BR30/R/RP
120 6
Red Reflector Flood
C, CC-6
2000
5.38
2,46,57,
65BR30/Y/RP
120 6
Yellow Reflector Flood
C, CC-6
2000
5.38
2,46,57,
65BR30/GRO/RP
120 6
Spot-GRO Reflector
C, CC-6
2000
5.38
65BR30/DL/2/24
120 24
Double Life Reflector
Flood
C, CC-6
4000
155
15151
155
15152
155
15153
155
15161
155
15154
155
15156
155
Med Brass
15266
For more complete product information visit www.sylvania.com
20
510lm
300 cd
60˚
5.38
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:57 AM
BR30, BR40
Page 21
PAR38
A19
GENERAL PURPOSE LAMPS
34
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Double Life Reflector
Flood
C, CC-6
4000
510lm
300 cd
60˚
5.38
120 24
Reflector Flood
C, CC-6
2000
580lm
390 cd
60˚
6.50
65BR/FL/RP
120 6
Reflector Flood
C, CC-6
2000
580lm
390 cd
60˚
6.50
65BR/CVP
130 6
Reflector Flood
C, CC-6
2000
540lm
390 cd
60˚
6.50
Pkg
Volts Qty
BR30 Med Brass
15177
65BR30/DL/FL/RP
120 6
BR40 Med
15360
46,57,155
65BR/FL/24
15678
46,57,155
46,57,106,
Watts Bulb
65
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
Base
2,46,57,155
15679
Description
136,155
|
|
|
@ 120 _volts, approximate 57 watts, 410 lumens, 5000 hours.
Med Brass
PAR38 Med Skt
15332
65BR/DL/FL/RP
120 6
Double Life Reflector
Flood
C, CC-6
4000
510lm
335 cd
60˚
6.50
13804
65PAR/SP
120 15
Spot Super Saver
C, CC-6
1750
715lm
5500 cd
12˚
5.31
13802
65PAR/FL
120 15
Flood Super Saver
C, CC-6
1750
715lm
1700 cd
30˚
5.31
65PAR/FL
130 15
Flood Super Saver
C, CC-6
1750
715lm
1700 cd
30˚
5.31
46,57,155
13805
136,173
@ 120 _volts, approximate 57 watts, 540 lumens, 4375 hours
67
A19
Med
11394
75A/67/W/ES/4PK
120 48
Soft White Energy Saver
C, CC-8
750
1040
3.13
4.44
11377
75A/67/SS
120 48
Standard Frost
SuperSaver
C, CC-8
750
1050
3.13
4.44
75A/67/SS
130 48
Standard Frost
SuperSaver
C, CC-8
750
1020
3.13
4.44
11381
136,175
@ 120 _volts, approximate 59 watts, 780 lumens, 1875 hours
Med Brass
11385
108
75A/67/SSXL
120 48
Standard Frost
SuperSaver XL
C, CC-8
2500
880
3.13
4.44
11389
108,136,174
75A/67/SSXL
130 48
Standard Frost
SuperSaver XL
C, CC-8
2500
860
3.13
4.44
@ 120 _volts, approximate 59 watts, 660 lumens, 6250 hours
75
A19
Med
10863
75A/DAY/4/160/RP
120 160
Daylight
C, CC-8
750
850
3.13
4.44
10865
75A/DAY/RP/4/48
120 48
Daylight
C, CC-8
750
850
3.13
4.44
11102
75A/DAY/RP/2/24
120 24
Daylight
C, CC-8
750
850
3.13
4.44
10776
102,136 75A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 66 watts, 650 lumens, 1875 hours.
Daylight
C, CC-8
750
850
3.13
4.44
11331
75A/W/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
1500
1055
3.13
4.44
11337
75A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
1500
1055
3.13
4.44
11175
75A/CL/DL/RP
120 24
Clear Double Life
C, CC-8
1500
1085
3.13
4.44
13001
75A/RS/2/RP
120 24
Inside Frost Rough
Service
C, C-9
1000
818
2.88
4.44
12579
75A/RS/RP/1
120 12
Inside Frost Rough
Service
C, C-9
1000
818
2.88
4.44
75A/RS/RP/1
130 24
Inside Frost Rough
Service
C, C-9
1000
818
2.88
4.44
12586
136,179
@ 120 _volts, approximate 66 watts, 620 lumens, 2500 hours
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 35-39
21
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
A19
7:57 AM
Page 22
A21
BR38
BR40
ER30
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
750
4.44
Watts Bulb
Base
75
Med
10970
75A/W/4/RP
120 48
Soft White
C, CC-8
10967
75A/W/RP
120 24
Soft White
C, CC-8
750
1170
3.13
4.44
12500
75A/CL
120 120
Clear
C, CC-8
750
1200
3.13
4.44
11225
75A/CL/RP
120 24
A19
Med Brass
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
1170
3.13
Clear
C, CC-8
750
1200
3.13
4.44
12502
136,183 75A/CL
130 120
@ 120 _volts, approximate 66 watts, 910 lumens, 1875 hours
Clear
C, CC-8
750
1190
3.13
4.44
12525
75A/4/RP
120 48
Standard Frost
C, CC-8
750
1190
3.13
4.44
12521
75A/RP
120 24
Standard Frost
C, CC-8
750
1190
3.13
4.44
11374
136,183 75A
130 48
@ 120 _volts, approximate 66 watts, 910 lumens, 1875 hours
Standard Frost
C, CC-8
750
1190
3.13
4.44
12510
183
75A/CVP
130 24
@ 120 _volts, approximate 66 watts, 910 lumens, 1875 hours
Standard Frost
C, CC-8
750
1190
3.13
4.44
13022
12528
81
75A/RS/XL
120 24
Inside Frost Rough
Service XL
C, C-9
5000
650
2.88
4.44
75A/RS/XL
130 24
Inside Frost Rough
Service XL
C, C-9
5000
700
2.88
4.44
|
|
|
@ 120 _volts, approximate 66 watts, 500 lumens, 12500 hours.
A21
Med
12554
Med Brass
11566
BR38 Med
Med Brass
116
75A21/RS/SL/RP
120 12
Safeline Rough Service
Inside Frost
C, C-9
1000
800
3.13
4.44
75A21
12
Inside Frost RV-Marine
C, C-6
1000
1420
3.88
5.31
24
15620
2,155
75/OPAR/BUG/RP
120 6
Outdoor Bug Light
C, CC-6
2000
15607
2,107,119,
75/OPAR/FL
120 12
Outdoor Reflector
Economy Flood
C, CC-6
2000
650lm
45˚
5.31
46,57,107,
75BR40/FL/DAY/1/6/RP
120 6
Daylight Reflector
Flood
C, CC-6
2000
680lm
310 cd
60˚
6.50
46,57,107,
75BR/FL
120 24
Reflector Flood
C, CC-6
2000
680lm
460 cd
60˚
6.50
46,57,107,
75BR/FL/RP
120 6
Reflector Flood
C, CC-6
2000
680lm
460 cd
60˚
6.50
46,57,107,
75BR/FL
130 24
Reflector Flood
C, CC-6
2000
680lm
460 cd
60˚
6.50
155
BR40 Med
15349
155
15126
155
15128
155
15125
136,155,184
5.31
@ 120 _volts, approximate 66 watts, 520 lumens, 5000 hours
Med Brass
ER30
Med
15213
46,57,107,155
75BR40/DL/FL/1/24
120 24
Double Life Reflector
Flood
C, CC-6
4000
610lm
400 cd
60˚
6.50
15144
46,57,107,155
75BR/DL/FL/RP
120 6
Double Life Reflector
Flood
C, CC-6
4000
610lm
400 cd
60˚
6.50
2,46,57,107,
75ER30
120 24
Elliptical Reflector
Flood
C, CC-6
2000
580lm
1500 cd
30˚
6.38
75ER30/RP
120 6
Elliptical Reflector
Flood
C, CC-6
2000
580lm
1500 cd
30˚
6.38
75ER30
130 24
Elliptical Reflector
Flood
C, CC-6
2000
580lm
1500 cd
30˚
6.38
15100
155
15109
2,46,57,107,
155
15101
2,46,57,107,
136,155,178
@ 120 _volts, approximate 66 watts, 425 lumens, 4125 hours
For more complete product information visit www.sylvania.com
22
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
K19
7:58 AM
Page 23
PAR38 Side Prong
R20
A19
GENERAL PURPOSE LAMPS
34
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
75
Med
12583
75K19/DR
120 24
Inside Frost
Directional Reflector
C, CC-6
1150
855lm
4.13
PAR38 Med Side
Prong
13850
75PAR/3FL
120 12
Compact Flood
C, CC-6
2000
1040lm
1800 cd
30˚
4.31
R20
Med
14840
75R20/RP
120 6
Reflector Flood
C, CC-9
2000
500lm
500 cd
45˚
3.94
R30
Med
15146
75R30/BLACKLIGHT/RP
120 6
Blacklight
C, CC-6
1000
A19
Med
11396
100A/90/W/ES/4PK
120 48
Soft White Energy Saver
C, CC-8
750
1450
3.13
4.44
11378
100A/90/SS
120 48
Standard Frost
SuperSaver
C, CC-8
750
1480
3.13
4.44
100A/90/SS
130 48
Standard Frost
SuperSaver
C, CC-8
750
1480
3.13
4.44
90
K19
68,107,118
11382
136,189
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
Description
|
|
|
6.50
@ 120 _volts, approximate 79 watts, 1130 lumens, 1875 hours
Med Brass
11386
108
100A/90/SSXL
120 48
Standard Frost
SuperSaver XL
C, CC-8
2500
1220
3.13
4.44
11390
108,136,186
100A/90/SSXL
130 48
Standard Frost
SuperSaver XL
C, CC-8
2500
1230
3.13
4.44
@ 120 _volts, approximate 79 watts, 940 lumens, 6250 hours
100
A19
Med
12948
100A/DAY/4/160/RP
120 160
Daylight
C, CC-8
750
1270
3.13
4.44
12587
100A/DAY/RP/4/48
120 48
Daylight
C, CC-8
750
1270
3.13
4.44
12952
100A/DAY/RP/2/24
120 24
Daylight
C, CC-8
750
1270
3.13
4.44
12538
103,136 100A/DAY/RP/4/48
130 48
@ 120 _volts, approximate 88 watts, 970 lumens, 1875 hours.
Daylight
C, CC-8
750
1270
3.13
4.44
16868
100A/DL/SW/PLUS/4PK/RP/160 120 160
Soft White Double Life
C, CC-8
1500
1560
3.13
4.44
16864
100A/DL/SW/PLUS/4PK/RP
120 48
Soft White Double Life
C, CC-8
1500
1560
3.13
4.44
100A/DL/SW/4PK/RP
120 48
Soft White Double Life
C, CC-8
1500
1530
3.13
4.44
100A/DL/SW/PLUS/2PK/RP
120 24
Soft White Double Life
C, CC-8
1500
1560
3.13
4.44
100A/DL/SW/2PK/RP
120 24
Soft White Double Life
C, CC-8
1500
1530
3.13
4.44
100A/CL/DL/PLUS/2PK/RP
120 24
Clear Double Life
C, CC-8
1500
1590
3.13
4.44
11332
108
12480
12805
108
11660
11176
100A/CL/DL/RP
120 24
Clear Double Life
C, CC-8
1500
1550
3.13
4.44
13002
100A/RS/2/RP
120 24
Inside Frost Rough
Service
C, C-9
1000
1260
2.88
4.44
12997
100A/RS/RP/1
120 12
Inside Frost Rough
Service
C, C-9
1000
1260
2.88
4.44
100A/RS/2/RP
130 24
Inside Frost Rough
Service
C, C-9
1000
1260
2.88
4.44
12998
108
136,190
@ 120 _volts, approximate 88 watts, 960 lumens, 2500 hours
12770
100A/W/4/RP
120 48
Soft White
C, CC-8
750
1690
3.13
4.44
12752
100A/W/RP
120 24
Soft White
C, CC-8
750
1690
3.13
4.44
12529
100A/CL
120 120
Clear
C, CC-8
750
1720
3.13
4.44
11226
100A/CL/RP
120 24
Clear
C, CC-8
750
1720
3.13
4.44
12531
136,193 100A/CL
130 120
@ 120 _volts, approximate 88 watts, 1290 lumens, 1875 hours
Clear
C, CC-8
750
1700
3.13
4.44
12750
100A/4/RP
120 48
Standard Frost
C, CC-8
750
1710
3.13
4.44
12735
100A/RP
120 24
Standard Frost
C, CC-8
750
1710
3.13
4.44
11375
136,193 100A
130 48
@ 120 _volts, approximate 88 watts, 1290 lumens, 1875 hours
Standard Frost
C, CC-8
750
1700
3.13
4.44
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 35-39
23
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
A19
7:58 AM
Page 24
A21
A23
BR38
BR40
K19
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Watts Bulb
Base
100
Med
A19
Med Brass
Description
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
12709
136,193 100A/CVP
130 24
@ 120 _volts, approximate 88 watts, 1290 lumens, 1875 hours
Standard Frost
C, CC-8
750
1700
3.13
4.44
12530
100A/LHT
120 120
Standard Frost Left
Hand Thread
C, CC-8
750
1710
3.13
4.44
12763
100A/Y/RP
120 24
Yellow Bug Light
C, CC-8
1000
3.13
4.44
12766
100A/SPK/RP
120 24
Soft Pink
C, CC-8
1000
3.13
4.44
13023
100A/RS/XL
120 24
Inside Frost Rough
Service XL
C, C-9
5000
840
2.88
4.44
100A/RS/XL
130 24
Inside Frost Rough
Service XL
C, C-9
5000
1040
2.88
4.44
Inside Frost Vibration
Service
C, C-9
1000
1340
3.88
5.31
120 48
Standard Frost
C, CC-8
750
1675
3.88
5.31
12883
136,192
100A21
130 48
@ 120 _volts, approximate 88 watts, 1260 lumens, 1875 hours
Standard Frost
C, CC-8
750
1650
3.88
5.31
Product Symbols &
Number Footnotes Ordering Abbreviation
12559
82,136
Pkg
Volts Qty
|
|
|
@ 120 _volts, approximate 88 watts, 765 lumens, 12500 hours.
A21
Med
13218
100A21/VS
83
130 48
@ 120 _volts, approximate 88 watts, 1020 lumens, 2500 hours.
12866
Med Brass
100A21
13404
100A21
230 24
Standard Frost
C, C-9
1000
1260
3.88
5.31
13406
100A21
250 24
Standard Frost
C, C-9
1000
1230
3.88
5.31
13397
100A21
277 24
Standard Frost
C, C-7A
1000
1042
3.88
5.31
12909
100A21/LHT
120 48
Standard Frost Left
Hand Thread
C, CC-8
750
1675
3.88
5.31
12834
116
100A21/SL
120 48
Safeline Rhinocoat
(Shatter Protected)
C, CC-8
750
1675
3.88
5.31
12992
116
100A21/RS/SL/RP
120 12
Safeline Rough Service
C, C-9
1000
1260
3.13
4.44
12906
108
100A21/99/XL
120 48
Standard Frost Excel
C, CC-8
2500
1400
3.88
5.31
12946 108,136,191
100A21/99/XL
130 48
@ 120 _volts, approximate 88 watts, 1100 lumens, 6250 hours
Standard Frost Excel
C, CC-8
2500
1440
3.88
5.31
Med
12859
Med Brass
13280
BR38 Med Brass
15626
A23
100A23
34
12
Inside Frost
C, C-9
1000
1800
4.38
6.06
100A23/20
120 24
Clear Oven
C, C-9
750
1390
4.38
6.06
2,46,57,
100/OPAR/FL/B/RP
120 6
Blue Reflector Flood
C, CC-6
2000
5.31
2,46,57,
100/OPAR/FL/G/RP
120 6
Green Reflector Flood
C, CC-6
2000
5.31
2,46,57,
100/OPAR/FL/R/RP
120 6
Red Reflector Flood
C, CC-6
2000
5.31
2,46,57,
100/OPAR/FL/Y/RP
120 6
Yellow Reflector Flood
C, CC-6
2000
5.31
14851
57,107,155
100BR/FL
120 24
Reflector Flood
C, CC-6
2000
935lm
900 cd
60˚
6.50
14871
57,107,155
100BR/FL/RP
120 6
Reflector Flood
C, CC-6
2000
935lm
900 cd
60˚
6.50
130 24
Reflector Flood
C, CC-6
2000
935lm
900 cd
60˚
6.50
Inside Frost
Directional Reflector
C, CC-6
1150
1235
4.13
108
155
15627
155
15623
155
15622
155
BR40 Med
14847
57,107,136, 100BR/FL
155,194
@ 120 _volts, approximate 88 watts, 710 lumens, 5000 hours
K19
Med
12298
100K19/DR
For more complete product information visit www.sylvania.com
24
120 24
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:58 AM
PAR38
Page 25
PS25
A23
BR40
ER40
A19
A21
GENERAL PURPOSE LAMPS
34
Watts Bulb
Base
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
Hard Glass PAR Heat
Lamp with Red Lens
C
5000
120 12
Inside Frost 3-way
100/300W
C, CC-8
1200
1385lm
3540lm
4925lm
4.25
6.75
K105A23/CL
125 24
Clear Krypton Filled ST
Ltg
C, C-9
12000
1120
4.38
6.06
120BR40/FL/SL
130 24
RHINOCOAT Safeline
Flood
C, CC-6
2000
1150lm
1000 cd
60˚
6.50
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
100PAR38/HEAT/RED
120 15
100/300PS25/RP
100
PAR38 Med Skt
13849
100
200
300
PS25
3 CONTACT
Med
14374
105
A23
Med Brass
13364
120
BR40 Med
24,46,155
57,108
15074
2,46,57,
107,155
Description
MOL
(in)
|
|
|
@ 120 _volts, approximate 105 watts, 850 lumens, 5000 hours
14903
2,46,57,
120BR/FL
120 24
Reflector Flood
C, CC-6
2000
1150lm
1000 cd
60˚
6.50
120BR/FL/RP
120 6
Reflector Flood
C, CC-6
2000
1150lm
1000 cd
60˚
6.50
120BR/FL
130 24
Reflector Flood
C, CC-6
2000
1150lm
1000 cd
60˚
6.50
Reflector Flood
C, CC-6
2000
1150lm
1000 cd
60˚
6.50
107,155
14896
2,46,57,
107,155
14899
2,107,136,
155,196
@ 120 _volts, approximate 105 watts, 850 lumens, 5000 hours
14888
2,46,57,
120BR/FL/CVP
130 6
107,136,155,196
@ 120 _volts, approximate 105 watts, 850 lumens, 5000 hours
14911
2,46,57,
120BR/SP
120 24
Reflector Spot
C, CC-6
2000
1150lm
3300 cd
25˚
6.50
120BR/SP/RP
120 6
Reflector Spot
C, CC-6
2000
1150lm
3300 cd
25˚
6.50
120BR/SP
130 24
Reflector Spot
C, CC-6
2000
1150lm
3300 cd
25˚
6.50
107,155
14897
2,46,57,
107,155
14909
2,46,57,
107,136,155,196
@ 120 _volts, approximate 105 watts, 850 lumens, 5000 hours
14898
2,46,57,
120BR/GRO
120 6
Spot-GRO Reflector
C, CC-6
2000
6.50
120BR/DL/FL/RP
120 6
Double Life Reflector
Flood
C, CC-6
4000
960lm
835 cd
60˚
6.50
120ER40
120 24
Elliptical Reflector
Flood
C, CC-6
2000
1370lm
2350 cd
30˚
7.38
155
Med Brass
14915
2,46,57,107,
155
ER40
Med
15166
2,46,57,107,
155
125
135
BR40 Med
A19
Med Brass
A21
Med
15451
57,155
125BR40/HEAT/24PK
120 24
Reflector Infrared Heat
Lamp
C, C-9
4000
6.50
14952
57,155
125BR40/1/RP
120 6
Reflector Infrared
Brooder Bulb
C, CC-6
5000
6.50
12831
3,108,136
150A/135/SS/XL
130 120
Standard Frost
SuperSaver XL
C, CC-8
2500
2050
3.13
4.44
@ 120 _volts, approximate 119 watts, 1560 lumens, 6250 hours
12820
12863
4,136
150A21/135/SS
120 48
Standard Frost
SuperSaver
C, CC-8
750
2450
3.88
5.50
150A21/135/SS
130 48
Standard Frost
SuperSaver
C, CC-8
750
2450
3.88
5.50
@ 120 _volts, approximate 119 watts, 1870 lumens, 1875 hours
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 35-39
25
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
A21
7:58 AM
A23
Page 26
BR38
PAR38
PAR38 Side Prong
PAR46
PS25
T10
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Description
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
C, CC-8
750
5.31
Watts Bulb
Base
150
Med
13101
150A21/W/RP
120 12
Soft White
13125
150A21/CL/RP
120 12
A21
Med Brass
A23
Med
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
2640
3.88
Clear Utility Light
C, CC-8
750
2780
3.88
5.31
13148
12,136
150A21/CL
130 48
@ 120 _volts, approximate 132 watts, 2030 lumens, 1875 hours
Clear
C, CC-8
750
2730
3.88
5.31
13141
150A21
120 48
Standard Frost
C, CC-8
750
2740
3.88
5.31
13165
150A21/IF/RP
120 12
Standard Frost Utility
Light
C, CC-8
750
2740
3.88
5.31
13153
12,136
150A21
130 48
@ 120 _volts, approximate 132 watts, 2030 lumens, 1875 hours
Standard Frost
C, CC-8
750
2670
3.88
5.31
13177
120 48
Standard Frost Excel
C, CC-8
2500
2225
3.88
5.31
13178 10,108,136
150A21/99/XL
130 48
@ 120 _volts, approximate 132 watts, 1690 lumens, 6250 hours
Standard Frost Excel
C, CC-8
2500
2225
3.88
5.31
15241
150A21/99/XL
108
15243
7,136
150A23/RS
120 48
Inside Frost Rough
Service
C, C-17
1000
2090
4.38
6.06
150A23/RS
130 48
Inside Frost Rough
Service
C, C-17
1000
2090
4.38
6.06
4.63
6.06
|
|
|
@ 120 _volts, approximate 132 watts, 1590 lumens, 2500 hours
13041
BR38 Med Brass
15608
150A23
120 48
Inside Frost
C, CC-8
750
2810
2,107,
150/OPAR/FL
120 12
Outdoor Reflector
Economy Flood
C, CC-6
2000
1350lm
45˚
5.31
8,119
150PAR/SP
130 15
Spot
C, CC-6
750
2175lm
18000 cd
12˚
5.31
Flood
C, CC-6
750
2175lm
4500 cd
30˚
5.31
119,155
PAR38 Med Skt
13921
@ 120 _volts, approximate 132 watts, 1660 lumens, 1875 hours
13922
8,119
150PAR/FL
130 15
@ 120 _volts, approximate 132 watts, 1660 lumens, 1875 hours
Med Side
Prong
13853
188
PAR46 Med Side
Prong
15375
Screw Term
15190
Med
15276
PS25
Med Brass
T10
175
200
S14s
PAR38 Med Skt
A21
Med
150PAR/3FL
120 12
Compact Flood
C, CC-6
2000
2175lm
4000 cd
30˚
4.31
57,117,188
150PAR46/3NSP 125-
125 12
Narrow Spot
C, CC-2V
2000
1500lm
17500 cd
8x12 VH
4.00
57,188
150PAR46
130 12
Clear Mine Headlamp
C, C-13
1000
1250lm
8x15 VH
3.75
150PS25/IF
120 60
Inside Frost
C, C-9
1000
2340
5.25
6.94
15282
9,108,136
150PS25
130 60
@ 120 _volts, approximate 132 watts, 1770 lumens, 1875 hours
Inside Frost
C, C-9
750
2330
5.25
6.94
15293
116
150PS25/SL
120 60
Safeline Rhinocoat
(Shatter Protected)
C, C-9
1000
2200
5.25
6.94
15300
116
150PS25/RS/SL
108
120 60
Safeline Rough Service
C, C-17
1000
2145
4.38
5.94
15431 5,108,136
150PS25/99/XL
130 60
@ 120 _volts, approximate 132 watts, 1420 lumens, 6250 hours
Inside Frost Excel-Line
C, C-9
2500
1870
5.25
6.94
19690
930
LN150 125-130
125 16
Opal White LINESTRA
1604
B, C-8
1000
13836
24,46,155
175W/PAR38/HEAT
120 15
Hard Glass PAR Heat
Lamp
C, CC-6
5000
13840
24,46,155
175 PAR38/HEAT/RED
120 15
Hard Glass PAR Heat
Lamp with Red Lens
C
5000
200A21/W/1RP
120 12
Soft White
C, CC-8
750
13103
For more complete product information visit www.sylvania.com
26
39.38
5.31
3650
3.88
5.31
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:58 AM
A21
Page 27
A23
PAR46
PAR56
PS25
PS30
BR38
BR40
GENERAL PURPOSE LAMPS
34
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Watts Bulb
Base
200
Med
13107
200A21
120 24
Soft White Recessed
Ceiling
C, CC-8
750
3650
3.88
5.31
15476
200A21/CL/RP
120 12
Clear Utility Light
C, CC-8
750
3880
3.88
5.31
15491
21,136
200A21/CL
130 48
@ 120 _volts, approximate 176 watts, 2860 lumens, 1875 hours
Clear
C, CC-8
750
3880
3.88
5.31
15499
Standard Frost Utility
Light
C, CC-8
750
3850
3.88
5.31
15543
21,136
200A21
130 48
@ 120 _volts, approximate 176 watts, 2860 lumens, 1875 hours
Standard Frost
C, CC-8
750
3760
3.88
5.31
Med Brass
15555 22,136
200A21/99/XL
125 48
@ 120 _volts, approximate 176 watts, 2220 lumens, 6750 hours
Standard Frost Excel
C, CC-8
2500
2910
3.88
5.31
Med
15458
Inside Frost Rough
Service
C, C-17
1000
2920
4.38
5.88
4.63
A21
A23
200A21/RP
200A23/RS
15,136
Pkg
Volts Qty
Class &
Filament
Product Symbols &
Number Footnotes Ordering Abbreviation
120 12
130 48
Description
|
|
|
@ 120 _volts, approximate 176 watts, 2220 lumens, 2500 hours
15505
PAR46 Med Side
Prong
200A23
15191
120 48
Inside Frost
C, CC-8
750
3930
57,117, 200PAR46/3NSP
120 12
Narrow Spot
C, CC-13
2000
2270lm
31000 cd
8x12 VH
4.00
57,117, 200PAR46/3MFL
120 12
Med Flood
C, CC-13
2000
2270lm
11500 cd
15x25 VH
4.00
57,117, 200PAR46/3MFL 125-
125 12
Med Flood
C, CC-13
2000
2270lm
11500 cd
15x25 VH
4.00
200PAR56/MFL
120 12
Med Flood Clear
C, CC-13
2000
2270lm
15000 cd
15x20 VH
5.00
200PAR56
30
Locomotive Headlamp
C, CC-8
500
3700lm
27000 cd
9x9 VH
4.50
188
15194
188
15196
188
PAR56 Mog End
Prong
PS25
PS30
15007
57,117,188
Screw Term
14968
Med
15600
20,136
200PS25
130 60
@ 120 _volts, approximate 176 watts, 2820 lumens, 1875 hours
Inside Frost
C, CC-6
750
3700
5.25
6.94
Med Brass
15818 17,136
200PS25/99/XL
130 60
@ 120 _volts, approximate 176 watts, 2360 lumens, 6250 hours
Inside Frost Excel-Line
C, CC-6
2500
3000
5.25
6.94
Med
15675
Inside Frost Rough
Service
C, C-9
1000
3080
6.00
8.06
15653
18,136
200PS/IF
130 60
@ 120 _volts, approximate 176 watts, 2710 lumens, 1875 hours
Inside Frost
C, C-9
750
3560
6.00
8.06
15820
16,136
200PS/23
12
6.06
130 60
@ 120 _volts, approximate 176 watts, 2350 lumens, 2500 hours
Med Brass
Med Brass
200/CL
277 60
Clear
C, C-9
1000
2360
6.00
8.06
15687
116
200PS/23/SL
120 60
Safeline Rough Service
C, C-9
1000
3080
6.00
8.06
15648
116
200PS/SL
120 60
Safeline
C, C-9
1000
3080
6.00
8.06
15725 14,136
200PS/CL/99/XL
130 60
@ 120 _volts, approximate 176 watts, 2190 lumens, 6250 hours
Clear Excel-Line
C, C-9
2500
2875
6.00
8.06
15581
Clear Street Lighting
Group Replacement
C, C-9
6000
2750
5.25
6.94
3100
202
PS25
202PS25/CL
250
BR38 Med Brass
14661
25,46,136
250K/BR38/FL
125 12
@ 120 _volts, approximate 220 watts, 2360 lumens, 10000 hours
Reflector Flood Krypton
C, CC-6
4000
BR40 Med
14665
24,46,57,155
250BR40
120 12
Reflector IR Heat Lamp
Clear
C, CC-6
5000
6.50
14664
24,46,57,155
250BR40/1
120 6
Reflector IR Heat Lamp
Clear
C, CC-6
5000
6.50
57
For more complete product information visit www.sylvania.com
125 60
5.81
Symbols/Footnotes on page 35-39
27
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
R40
7:58 AM
Page 28
BR40
PAR56
PS30
PS35
GENERAL PURPOSE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
34
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
Red Bowl IR Heat Lamp
Reflector Hard Glass
C, C-6
5000
6.88
120 24
Reflector Flood
C, CC-2V
2000
3030lm
2900 cd
60˚
6.50
Watts Bulb
Base
Product Symbols &
Number Footnotes Ordering Abbreviation
250
R40
Med
14663
300
BR40 Med Brass
14779
PAR56 Mog End
Prong
14947
117,188
300PAR56/NSP
120 12
Narrow Spot
C, CC-13
2000
3840lm
68000 cd
8x10 VH
5.00
14944
117,188
300PAR56/NSP
130 12
Narrow Spot
C, CC-13
2000
3840lm
68000 cd
8x10 VH
5.00
14950
117,188
300PAR56/MFL
120 12
Med Flood
C, CC-13
2000
3840lm
24000 cd
11x25 VH
5.00
14946
117,188
300PAR56/MFL
130 12
Med Flood
C, CC-13
2000
3840lm
24000 cd
11x25 VH
5.00
14953
117,188
300PAR56/WFL
120 12
Wide Flood
C, CC-13
2000
3840lm
11000 cd
20x35 VH
5.00
14945
117,188
300PAR56/WFL
130 12
Wide Flood
C, CC-13
2000
3840lm
11000 cd
20x35 VH
5.00
4.50
PS30
24,46,57,155
2,46,57,155
Pkg
Volts Qty
250R40/10
120 6
300BR/FL
Description
Screw Term
14967
25A/PAR56/WFL
12
12
Swimming Pool
C, C-6
1000
6000lm
15x40 VH
Med
15742
300M/CL
120 60
Clear Utility Light
C, C-9
750
5870
6.00
8.06
15740
300M/CL/RP
120 12
Clear Utility Light
C, C-9
750
5870
6.00
8.06
15744
29,136
300M/CL
130 60
@ 120 _volts, approximate 264 watts, 4390 lumens, 1875 hours
Clear Utility Light
C, C-9
750
5820
6.00
8.06
15737
300M/IF
120 60
Inside Frost Utility
Light
C, C-9
750
5860
6.00
8.06
15735
300M/IF/RP
120 12
Inside Frost Utility
Light
C, C-9
750
5860
6.00
8.06
300M/IF
130 60
Inside Frost Utility
Light
C, C-9
750
5760
6.00
8.06
Inside Frost Utility
Light
C, C-9
750
5760
6.00
8.06
15739
29,136
|
|
|
@ 120 _volts, approximate 264 watts, 4390 lumens, 1875 hours
15738
29
300M/IF/CVP/6
130 6
@ 120 _volts, approximate 264 watts, 4390 lumens, 1875 hours
PS35
375
R40
Med Brass
15761 27,136
300M/IF/99/XL
130 60
@ 120 _volts, approximate 264 watts, 3800 lumens, 6250 hours
Inside Frost Excel-Line
C, C-9
2500
4990
6.00
8.06
Mogul
15904
300PS35/CL/99/XL
120 24
Clear Excel-Line
C, C-9
2500
5190
7.00
9.38
15930
300PS35/99IF/XL
130 24
Inside Frost Excel-Line
C, C-9
2500
5070
7.00
9.38
15915
300PS35/CL
120 24
Clear Utility Light
C, C-9
1000
5700
7.00
9.38
15917
300PS35/CL
130 24
Clear Utility Light
C, C-9
1000
5250
7.00
9.38
15918
300PS35/IF
120 24
Inside Frost Utility
Light
C, C-9
1000
5700
7.00
9.38
15920
300PS35/IF
130 24
Inside Frost Utility
Light
C, C-9
1000
5250
7.00
9.38
16068
300PS35/CL
277 24
Clear
C, C-7A
1000
4220
7.00
9.38
375R40/1
120 24
Reflector IR Heat Lamp
Clear
C, C-11
5000
Med Skirted
14747
24,46
For more complete product information visit www.sylvania.com
28
7.63
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:58 AM
PAR64
Page 29
PS35
CA8, CA10, CA5
B10
F10
G16.5
GENERAL PURPOSE LAMPS
34
Watts Bulb
500
Base
PAR64 Ext Mog End
Pr
PS35
Mogul
Description
Class &
Filament
Avg
Lumens
Rated Beam Angle LCL
Life(hrs) CBCP
(in)
MOL
(in)
120 6
Narrow Spot
C, CC-13
2000
6500lm
110000 cd
7x12 VH
6.00
500PAR64/MFL
120 6
Med Flood
C, CC-13
2000
6500lm
37000 cd
11x25 VH
6.00
500PAR64/WFL
120 6
Wide Flood
C, CC-13
2000
6500lm
13000 cd
20x40 VH
6.00
16032
500PS35/CL
120 24
Clear
C, CC-8
1000
10000
7.00
9.38
16034
500PS35/CL
130 24
Clear
C, CC-8
1000
10000
7.00
9.38
16040
500PS35/IF
130 24
Inside Frost
C, CC-8
1000
10000
7.00
9.38
Product Symbols &
Number Footnotes Ordering Abbreviation
Pkg
Volts Qty
14938
57,117,188
500PAR64/NSP
14932
57,117,188
14935
57,117,188
|
|
|
DECORATIVE LAMPS
1
Product Symbols &
Number Footnotes
Ordering Abbreviation
Pkg
Volts Qty Description
Class &
Filament
Avg
Rated
Life(hrs)
MOL
(in)
Watts Bulb
Base
3
CA8
Candelabra
11688
3CA8C/CL/FL/BL/1/6
120
6
Clear Flicker
B
1500
3.50
CA10
Med
11689
3CA10/CL/FL/BL/1/6
120
6
Clear Flicker
B
1500
3.50
7.5
CA5
Candelabra
11687
7.5CA5C/CL/BL/3/18
120
18
Clear Décor Bent Tip
B, C-11V
3000
3.06
15
B10
Candelabra
13315
15B10C/DL/BL
120
12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13657
15B10C/BAGPK
120
200 Clear Décor Bent Tip
C, C-7A
1500
3.88
13448
15B10C/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.88
13675
Med
F10
G16.5
25
B10
Candelabra
Candelabra
Candelabra
15B10C/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.63
13433
94
15B10/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.81
13715
94
15B10/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.56
13435
15FC/AIC/BL/2PK
120
12
Amber Flame Shape
Iridescent
B, C-7A
1500
3.06
13434
15FC/IC/BL/2PK
120
12
Clear Iridescent Flame
Shape
B, C-7A
1500
3.06
13436
15FC/W/BL/2PK
120
12
White Flame Shape
B, C-7A
1500
3.06
13709
15G16.5C/4M
120
24
Clear Globe
B, C-7A
4000
3.00
13616
15G16.5C
120
24
Clear Globe
B, C-7A
1500
3.00
13617
15G16.5C/W
120
24
White Globe
B, C-7A
1500
3.00
13306
25B10C/DL/BL/4PK
120
24
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13316
25B10C/DL/BL
120
12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13570
25B10C/BAGPK
120
200 Clear Décor Bent Tip
C, C-7A
1500
3.88
13452
25B10C/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.88
13678
25B10C/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.63
13743
25B10C/CRYSTAL/DL/BL/2PK
120
12
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13308
25B10C/DL/F/BL/4PK
120
24
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13317
25B10C/DL/F/BL
120
12
Frosted Double Life
Décor Bent Tip
C, C-2V
3000
3.88
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 35-39
29
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
B10
7:58 AM
C11
Page 30
F15
G16.5
G25
G40
DECORATIVE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
1
Ordering Abbreviation
Pkg
Volts Qty Description
Class &
Filament
Avg
Rated
Life(hrs)
MOL
(in)
25B10C/F/BL/2PK
120
12
Frosted Décor Bent Tip
C, C-7A
1500
3.88
Watts Bulb
Base
Product Symbols &
Number Footnotes
25
Candelabra
13453
Med
13331
94
25B10/DL/BL/4PK
120
24
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
13318
94
25B10/DL/BL
120
12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
13654
94
25B10/BL/4PK
120
24
Clear Décor Bent Tip
C, C-7A
1500
3.81
13438
94
25B10/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.81
13717
94
25B10/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.56
13439
94
B10
25B10/F/BL/2PK
120
12
Frosted Décor Bent Tip
C, C-7A
1500
3.81
C11
Candelabra
11690
25C11C/AM/SG/BL/1/6
120
6
Spun-Glo Amber Fiber
Wrapped
C, C-7A
1500
4.25
F15
Med
13823
25F/AIC/BL/2PK
120
12
Amber Flame Shape
Iridescent
C, C-7A
1500
4.50
13806
25F/CL
120
24
Clear Flame Shape
C, C-7A
1500
4.50
13862
25F/CL/BL/2PK
120
12
Clear Flame Shape
C, C-7A
1500
4.50
13821
25F/IC/BL/2PK
120
12
Iridescent Flame Shape
C, C-7A
1500
4.50
13820
25F/W/BL/2PK
120
12
Soft White Flame Shape
C, C-7A
1500
4.50
G16.5
Candelabra
Med
G25
Med
10221
25G16.5C/DAY/2PK/BL
120
12
Daylight Globe
B, C-7A
1500
3.00
13704
25G16.5C/4M
120
24
Clear Globe
B, C-7A
4000
3.00
13618
25G16.5C
120
24
Clear Globe
B, C-7A
1500
3.00
13625
25G16.5C/BL
120
12
Clear Globe
B, C-7A
1500
3.00
13622
25G16.5C/W/BL
120
12
White Globe
B, C-7A
1500
3.00
10298
25G16.5/BL
120
12
Clear Globe
C, C-7A
1500
3.00
10297
25G16.5/W/BL
120
12
White Globe
C, C-7A
1500
3.00
14105
25G25/DL/RP/48
120
48
Clear Double Life Globe
C, C-9
3000
4.44
14145
25G25/DL/RP
120
6
Clear Double Life Globe
C, C-9
3000
4.44
14276
25G25/4M
120
24
Clear Globe
C, C-9
4000
4.44
14210
25G25/3PK/RP
120
24
Clear Globe
C, C-9
1500
4.44
14264
25G25
120
24
Clear Globe
C, C-9
1500
4.44
14282
25G25/RP
120
6
Clear Globe
C, C-9
1500
4.44
14103
25G25/DL/SW/RP/48
120
48
Soft White Double Life
Globe
C, C-9
3000
4.44
14146
25G25/DL/SW/RP
120
6
Soft White Double Life
Globe
C, C-9
3000
4.44
14277
25G25/W/4M
120
24
Soft White Globe
C, C-9
4000
4.44
14211
25G25/W/3PK/RP
120
24
Soft White Globe
C, C-9
1500
4.44
14265
25G25/W
120
24
Soft White Globe
C, C-9
1500
4.44
14286
25G25/W/RP
120
6
Soft White Globe
C, C-9
1500
4.44
G40
Med
14685
25G40
120
6
Clear Globe
C, C-9
2500
6.94
32
B10
Candelabra
13737
32B10C/CRYSTAL/DL/BL/2PK
120
12
Double Life Crystal
Bent Tip
C, C-7A
4000
3.88
40
B10
Candelabra
13751
40B10C/DAY/2PK/BL
120
12
Daylight Décor Bent Tip
C, C-7A
1500
3.88
13328
40B10C/DL/BL/4PK
120
24
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13319
40B10C/DL/BL/2PK
120
12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
For more complete product information visit www.sylvania.com
30
|
|
|
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:58 AM
B10
Page 31
B13
C15
F15
G16.5
DECORATIVE LAMPS
1
Ordering Abbreviation
Pkg
Volts Qty Description
Class &
Filament
Avg
Rated
Life(hrs)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
40
Candelabra
13571
40B10C/BAGPK
120
200 Clear Décor Bent Tip
C, C-7A
1500
3.88
13648
40B10C/BL/4PK
120
24
Clear Décor Bent Tip
C, C-7A
1500
3.88
13456
40B10C/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.88
13681
40B10C/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.63
13714
40B10C/CRYSTAL/DL/BL/4/24
120
24
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13741
40B10C/CRYSTAL/DL/BL/2PK
120
12
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13309
40B10C/DL/F/BL/4PK
120
24
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13320
40B10C/DL/F/BL/2PK
120
12
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13457
40B10C/F/BL/2PK
120
12
Frosted Décor Bent Tip
C, C-7A
1500
3.88
13682
40B10C/F/T/BL/2PK
120
12
Frosted Décor Blunt Tip
C, C-7A
1500
3.63
15354
40B10/DAY/2PK/BL
120
12
Daylight Décor Bent Tip
C, C-7A
1000
3.88
B10
Med
B13
13321
94
40B10/DL/BL/2PK
120
12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
13651
94
40B10/BL/4PK
120
24
Clear Décor Bent Tip
C, C-7A
1500
3.81
13440
94
40B10/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.81
13719
94
40B10/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.56
13723
94
40B10/CRYSTAL/DL/BL/4PK
120
24
Double Life Crystal
Bent Tip
C, C-7A
3000
3.81
13740
94
40B10/CRYSTAL/DL/BL/2PK
120
12
Double Life Crystal
Bent Tip
C, C-7A
3000
3.81
13322
94
40B10/DLF/BL/2PK
120
12
Frosted Double Life
Décor Bent Tip
C, C-2V
3000
3.81
13441
94
40B10/F/BL/2PK
120
12
Frosted Décor Bent Tip
C, C-7A
1500
3.81
13720
94
40B10/F/T/BL/2PK
120
12
Frosted Décor Blunt Tip
C, C-7A
1500
3.56
Candelabra
13357
40B13C/CL/FAN/2/12/BL
120
12
Clear Ceiling Fan Light
C, C-9
1500
4.00
Med
13366
40B13/DL/FAN/2/60/BL
120
60
Clear Double Life
Ceiling Fan
C, C-9
3000
4.63
13369
40B13/DL/FAN/BL/2PK
120
12
Clear Double Life
Ceiling Fan
C, C-9
3000
4.63
13367
40B13/FAN/BL/2PK
120
12
Clear Fan Lamp
C, C-9
1500
4.63
13786
40B13/CRYSTAL/FAN/4/72
120
72
Crystal Fan Lamp
C, C-9
1500
4.63
13785
40B13/CRYSTAL/FAN/BL/2PK
120
12
Crystal Fan Lamp
C, C-9
1500
4.63
C15
Med
11691
40C15C/AM/SG/BL/1/6
120
6
Spun Glo Amber Fiber
Wrap
C, C-9
1500
4.06
F15
Med
13986
40F/AIC/BL/2PK
120
12
Amber Flame Shape
Iridescent
C, C-7A
1500
4.50
13974
40F/CL
120
24
Clear Flame Shape
C, C-7A
1500
4.50
13985
40F/IC/BL/2PK
120
12
Iridescent Flame Shape
C, C-7A
1500
4.50
13984
40F/W/BL/2PK
120
12
White Flame Shape
C, C-7A
1500
4.50
G16.5
Candelabra
10367
40G16.5C/DAY/2PK/BL
120
12
Daylight Globe
C, C-7A
1500
3.00
13702
40G16.5C
120
24
Clear Globe
C, C-7A
1500
3.00
13346
40G16.5C/4PK/BL
120
24
Clear Globe
C, C-7A
1500
3.00
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 35-39
31
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
G16.5
7:58 AM
G25
Page 32
G30
G40
A19
B10
DECORATIVE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
1
Ordering Abbreviation
Pkg
Volts Qty Description
Class &
Filament
Avg
Rated
Life(hrs)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
40
Candelabra
13666
40G16.5C/BL
120
12
Clear Globe
C, C-7A
1500
3.00
13667
40G16.5C/W/BL
120
12
White Globe
C, C-7A
1500
3.00
10352
40G16.5/4PK/BL
120
24
Clear Globe
C, C-7A
1500
3.00
10300
40G16.5/BL
120
12
Clear Globe
C, C-7A
1500
3.00
10299
40G16.5/W/BL
120
12
White Globe
C, C-7A
1500
3.00
G16.5
Med
G25
60
Med
15350
40G25/CL/DAY/1/6
120
6
Daylight Clear Globe
C, C-9
1500
4.44
13966
40G25/DAY/1/6
120
6
Daylight Globe
C, C-9
1500
4.44
14174
40G25/DL/1/48
120
48
Clear Double Life Globe
C, C-9
3000
4.44
14147
40G25/DL/RP
120
6
Clear Double Life Globe
C, C-9
3000
4.44
14212
40G25/3PK/RP
120
24
Clear Globe
C, C-9
1500
4.44
14266
40G25
120
24
Clear Globe
C, C-9
1500
4.44
14283
40G25/RP
120
6
Clear Globe
C, C-9
1500
4.44
14191
40G25/CVP
130
6
Clear Globe
C, C-9
1500
4.44
14148
40G25/DL/SW/RP
120
6
Soft White Double Life
Globe
C, C-9
3000
4.44
14213
40G25/W/3PK/RP
120
24
Soft White Globe
C, C-9
1500
4.44
14267
40G25/W
120
24
Soft White Globe
C, C-9
1500
4.44
14287
40G25/W/RP
120
6
Soft White Globe
C, C-9
1500
4.44
14190
40G25/W/CVP
130
6
Soft White Globe
C, C-9
1500
4.44
15638
40G25/CT/1/6
120
6
Chrome Top Globe
C, C-9
1500
4.44
G30
Med
14405
40G30/W/RP
120
6
Soft White Globe
C, C-9
2500
5.50
G40
Med
14619
40G40/RP
120
6
Clear Globe
C, C-9
2500
6.94
14620
40G40/W/RP
120
6
Soft White Globe
C, C-9
2500
6.94
A19
Med Brass
10613
60A/SB
120
120 Silver Bowl
C, CC-8
1000
4.44
B10
Candelabra
13750
60B10C/DAY/2PK/BL
120
12
Daylight Décor Bent Tip
C, C-7A
1500
3.88
13705
60B10C/DL/BL/4PK
120
24
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13777
60B10C/DL/BL/2PK
120
12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.88
13572
60B10C/BAGPK
120
200 Clear Décor Bent Tip
C, C-7A
1500
3.88
13649
60B10C/BL/4PK
120
24
Clear Décor Bent Tip
C, C-7A
1500
3.88
13460
60B10C/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.88
13684
60B10C/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.63
13749
60B10C/CRYSTAL/DL/BL/4/24
120
24
Double Life Crystal
Bent Tip
C, C-7A
3000
3.88
13754
60B10C/DL/F/BL/4PK
120
24
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13778
60B10C/DL/F/BL/2PK
120
12
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.88
13461
60B10C/F/BL/2PK
120
12
Frosted Décor Bent Tip
C, C-7A
1500
3.88
13685
60B10C/F/T/BL/2PK
120
12
Frosted Décor Blunt Tip
C, C-7A
1500
3.63
13254
60B10/DL/BL/4PK
120
24
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
13323
60B10/DL/BL/2PK
120
12
Clear Double Life Décor
Bent Tip
C, C-7A
3000
3.81
Med
For more complete product information visit www.sylvania.com
32
|
|
|
Symbols/Footnotes on page 35-39
010_INC_F.qxd
11/29/07
7:58 AM
B10
Page 33
B13
C15
F15
G16.5
G25
G30
G40
A21
P25
DECORATIVE LAMPS
1
Ordering Abbreviation
Pkg
Volts Qty Description
Class &
Filament
Avg
Rated
Life(hrs)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
60
Med
13650
60B10/BL/4PK
120
24
Clear Décor Bent Tip
C, C-7A
1500
3.81
13442
60B10/BL/2PK
120
12
Clear Décor Bent Tip
C, C-7A
1500
3.81
13721
60B10/T/BL/2PK
120
12
Clear Décor Blunt Tip
C, C-7A
1500
3.56
13324
60B10/DL/F/BL/2PK
120
12
Frosted Double Life
Décor Bent Tip
C, C-7A
3000
3.81
B10
B13
13443
60B10/F/BL/2PK
120
12
Frosted Décor Bent Tip
C, C-2V
1500
3.81
Candelabra
13263
60B13C/CL/FAN/2/12/BL
120
12
Clear Ceiling Fan Light
C, C-9
1500
4.00
Med
13370
60B13/DL/FAN/BL/2PK
120
12
Clear Double Life Fan
Lamp
C, C-9
3000
4.63
13368
60B13/FAN/BL/2PK
120
12
Clear Fan Lamp
C, C-9
1500
4.63
13757
60C15/SG/BL
120
6
Spun-Glo Clear Fiber
Wrapped
C, C-9
4000
4.50
C15
Med
F15
Med
G16.5
G25
13993
60F/CL
120
24
Clear Flame Shape
C, C-7A
1500
4.50
13992
60F/BL
120
12
Clear Flame Shape
C, C-7A
1500
4.50
13982
60F/IC/BL/2PK
120
12
Iridescent Flame Shape
C, C-7A
1500
4.50
Candelabra
13665
60G16.5C/BL
120
12
Clear Globe
C, C-2
1500
3.00
13664
60G16.5C/W/BL
120
12
Soft White Globe
C, C-2
1500
3.00
Med
10382
60G16.5/4PK/BL
120
24
Clear Globe
C, C-7A
1500
3.00
10302
60G16.5/BL
120
12
Clear Globe
C, C-7A
1500
3.00
10301
60G16.5/W/BL
120
12
White Globe
C, C-7A
1500
3.00
15351
60G25/CL/DAY/1/6
120
6
Daylight Clear Globe
C, C-9
1500
4.44
13967
60G25/DAY/1/6
120
6
Daylight Globe
C, C-9
1500
4.44
14106
60G25/DL/RP/48
120
48
Clear Double Life Globe
C, C-9
3000
4.44
14149
60G25/DL/RP
120
6
Clear Double Life Globe
C, C-9
3000
4.44
14280
60G25
120
24
Clear Globe
C, C-9
1500
4.44
14214
60G25/3PK/RP
120
24
Clear Globe
C, C-9
1500
4.44
14261
60G25/RP
120
6
Clear Globe
C, C-9
1500
4.44
14104
60G25/DL/SW/RP/48
120
48
Soft White Double Life
Globe
C, C-9
3000
4.44
14150
60G25/DL/SW/RP
120
6
Soft White Double Life
Globe
C, C-9
3000
4.44
14215
60G25/W/3PK/RP
120
24
Soft White Globe
C, C-9
1500
4.44
14281
60G25/W
120
24
Soft White Globe
C, C-9
1500
4.44
14262
60G25/W/RP
120
6
Soft White Globe
C, C-9
1500
4.44
14407
60G30/RP
120
6
Clear Globe
C, C-9
2500
5.50
14406
60G30/W/RP
120
6
Soft White Globe
C, C-9
2500
5.50
14621
60G40/RP
120
6
Clear Globe
C, C-9
2500
6.94
60G40/W/RP
120
6
Soft White Globe
C, C-9
2500
6.94
100A21/1SB/IF
120
24
Silver Bowl
C, CC-6
1000
5.31
14623
100G40/RP
120
6
Clear Globe
C, C-9
2500
6.94
14624
100G40/W/RP
120
6
Soft White Globe
C, C-9
2500
6.94
150G40/W/RP
120
6
Soft White Globe
C, C-9
2500
6.94
150P25/2SB
120
60
Silver Bowl Clear Hard
Glass Button
C, C-5
200
4.75
Med
G30
Med
G40
Med
A21
Med
G40
Med
14622
100
150
13195
G40
Med
14913
P25
Med Brass
15014
46
46
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 35-39
33
I
N
C
A
N
D
E
S
C
E
N
T
010_INC_F.qxd
11/29/07
PS25
7:58 AM
Page 34
PS35
A19
A21
A23
DECORATIVE LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
1
Ordering Abbreviation
Pkg
Volts Qty Description
Class &
Filament
Avg
Rated
Life(hrs)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
150
PS25
Med
15271
150PS25/SB
120
60
Silver Bowl
C, C-9
1000
6.94
300
PS35
Mogul
15958
300PS35/SB/IF
120
24
Silver Bowl Inside
Frost Brass Base
C, C-9
1000
9.38
|
|
|
TRAFFIC SIGNAL LAMPS
3
Watts Bulb
Base
54
A19
Med Brass
10441
96,130
54A19TS/8M/SS
120 120
Clear Traffic Signal KR
Filled w/ Heat Reflector
C, C-11V 8000
515
2.44
4.44
60
A19
Med Brass
10442
96,130
60A19TS/8M/SS 120-
120 120
Clear Traffic Signal KR
Filled w/ Heat Reflector
C, C-11V 8000
595
2.44
4.44
67
A21
Med Brass
69
90
A21
A19
Med Brass
Med Brass
Pkg
Volts Qty
Description
Class &
Filament
Avg
Rated Approx
Life(hrs) Lumens
Product Symbols &
NumberFootnotes Ordering Abbreviation
LCL
(in)
MOL
(in)
12570
96
67A21/40/8M
120 24
Clear Traffic Signal
C, C-9
8000
610
2.44
4.44
12562
96
67A21/40/8M
130 120
Clear Traffic Signal
C, C-9
8000
610
2.44
4.44
12572
96
67A21/40/8M
130 24
Clear Traffic Signal
C, C-9
8000
610
2.44
4.44
12496
96
69A21/TS/8M
120 24
Clear Traffic Signal
C, C-9
8000
640
2.44
4.44
12497
96
69A21/TS/8M
125 24
Clear Traffic Signal
C, C-9
8000
665
2.44
4.44
12498
96
69A21/TS/8M
130 24
Clear Traffic Signal
C, C-9
8000
640
2.44
4.44
12299
96,130
90A19/1/TS/8M/SS 120-
120 120
Clear Traffic Signal KR
Filled w/ Heat Reflector
C, C-11V 8000
1000
3.00
4.44
90A19/TS/8M/SS
120 120
Clear Traffic Signal KR
Filled w/ Heat Reflector
C, C-11V 8000
1000
2.44
4.44
11151
96,130
101
A23
Med Brass
13305
96
101A23/6M
120 120
Inside Frost Traffic
Signal
C, C-9
6000
900
4.38
6.06
116
A21
Med Brass
12833
96
116A21/TS/8M
120 24
Clear Traffic Signal
C, C-9
8000
1260
2.44
4.44
12817
96
116A21/TS/8M
130 24
Clear Traffic Signal
C, C-9
8000
1260
2.44
4.44
135
A21
Med Brass
12843
96,130
135A21/TS/8M/SS 120-
120 24
Clear Traffic Signal KR
Filled w/ Heat Reflector
C, C-11V 8000
1750
3.00
4.44
170
A23
Med Brass
15017
96
1950L/A23/8M
120 60
Clear Traffic Signal
C, C-9
8000
1950
3.00
4.75
15021
96
1950L/A23/8M
130 60
Clear Traffic Signal
C, C-9
8000
1950
3.00
4.75
For more complete product information visit www.sylvania.com
34
|
|
|
Symbols/Footnotes on page 35-39
010_INCsf.qxd
11/29/07
8:08 AM
Page 35
SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS
Symbol
Description
I
N
C
A
N
D
E
S
C
E
N
T
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
Indicates aluminum base.
Do not operate in household sockets.
Operate base down.
Operate base down to horizontal.
Heat resistant, hard glass.
PAR lamps are suitable for indoor and outdoor use.
Do not operate in paper lined sockets.
This lamp or ballast meets minimum Federal efficiency standards.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
Footnote
Description
1
Indefinite long life. Designed for life in excess of 10,000 hours. In -service life depends upon burning conditions.
2
Should not be used in equipment where base temperature will exceed 500 F.
3
@ 120 volts, approximate 119 watts, 1560 lumens, 6250 hours
4
@ 120 volts, approximate 119 watts, 1870 lumens, 1875 hours
5
@ 120 volts, approximate 132 watts, 1420 lumens, 6250 hours
6
@ 120 volts, approximate 132 watts, 1580 lumens, 2500 hours
7
@ 120 volts, approximate 132 watts, 1590 lumens, 2500 hours
8
@ 120 volts, approximate 132 watts, 1660 lumens, 1875 hours
9
@ 120 volts, approximate 132 watts, 1770 lumens, 1875 hours
10
@ 120 volts, approximate 132 watts, 1690 lumens, 6250 hours
11
@ 120 volts, approximate 132 watts, 1880 lumens, 1875 hours
12
@ 120 volts, approximate 132 watts, 2030 lumens, 1875 hours
13
High temperature base. Designed to operate in equipment where base te mperature run between 500F - 570F.
14
@ 120 volts, approximate 176 watts, 2190 lumens, 6250 hours
15
@ 120 volts, approximate 176 watts, 2220 lumens, 2500 hours
16
@ 120 volts, approximate 176 watts, 2350 lumens, 2500 hours
17
@ 120 volts, approximate 176 watts, 2360 lumens, 6250 hours
18
@ 120 volts, approximate 176 watts, 2710 lumens, 1875 hours
19
@ 120 volts, approximate 176 watts, 2740 lumens, 1875 hours
20
@ 120 volts, approximate 176 watts, 2820 lumens, 1875 hours
21
@ 120 volts, approximate 176 watts, 2860 lumens, 1875 hours
22
@ 120 volts, approximate 176 watts, 2220 lumens, 6750 hours
23
@ 120 volts, approximate 188 watts, 3190 lumens, 1125 hours
24
Designed for service other than illumination.
25
@ 120 volts, approximate 220 watts, 2360 lumens, 10000 hours
26
@ 120 volts, approximate 264 watts, 2310 lumens, 5000 hours
27
@ 120 volts, approximate 264 watts, 3800 lumens, 6250 hours
For more complete product information visit www.sylvania.com
35
010_INCsf.qxd
11/29/07
8:08 AM
Page 36
SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
Footnote
Description
28
@ 120 volts, approximate 264 watts, 3850 lumens, 6250 hours
29
@ 120 volts, approximate 264 watts, 4390 lumens, 1875 hours
30
@ 120 volts, approximate 264 watts, 4305 lumens, 1875 hours
31
Additional product information can be found in the SYLVANIA Automotive, Miniature and Sealed Beam Lamp Catalog Form 208.
32
UV Filter capsule with axial filament in dichroic reflector.
33
UV Filter capsule with axial filament in aluminized reflector.
34
UV Filter capsule with axial filament in covered aluminized reflector .
35
2 3/4" circular window.
36
UV Filter capsule with axial filament in constant color, hard coated dichroic reflector.
37
UV Filter capsule with axial filament in constant color, hard coated Dichroic reflector and infrared reflective coating on the lamp capsule.
38
UV Filter capsule with axial filament in precisely engineered aluminum m reflector.
39
Suitable for indoor and outdoor use;
40
For indoor use only; suitable for outdoor use only if not directly exposed to weather
41
For indoor use only;
42
UV control capsule with transverse constant color filament in hard dichroic
43
State of the Art SPL Optics
44
Inner capsule with Infrared conserving coating and hard glass lens
45
UV Filter capsule with axial filament in covered dichroic reflector.
46
Operate only in porcelain sockets.
47
Infrared lamp technology
48
Caution: Operates under pressure and may shutter. Use appropriate techniques to protect people and surroundings. Do not operate in close
proximity to persons, combustible materials, or substances affected by heat or drying. Do not operate over 110% rated voltage because such
operation increases pressure and lamps' tendency to shatter. Ultraviolet output may cause skin and eye irritation with prolonged exposure.
Protect bulb from abrasions and scratches. Do not insert lamps when power is on. Follow operation
49
ECE Approved
50
Lamp Life B3 @ 13.2 volts.
51
Universal lamp housings for T2 slide based pilot lamps.
52
Socket dimensions front to panel to end of terminals.
53
UL File No. E31557(M) CSA File No.LR20904
54
Universal lamp housings for T2.5 and T3.25 miniature bayonet based lamps.
55
UL File No. E31557(M) CSA File No.LR20904
56
MIL-Std. 18236 B-MIL Std. 202B
57
Should be shielded against moisture falling on bulb.
58
Material : Black Phenolic
59
There are two distinctively different lamps with this part number. When ordering T-1 3/4 , #7327, please also specify category and base type.
S-11. #7327 discontinued.
60
MOL = Excluding pins.
61
Material : Plastic
62
Max. seal temperature 350 C (662F)
63
Max. bulb temperature 1000 C (1832F)
64
Min. bulb temperature 250 C (482F)
65
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector.
66
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector and infrared reflective coating on the lamp capsule.
67
UV Filter capsule with transverse filament in constant color, hard co ated dichroic reflector .
68
Not recommended for use in enclosed close-fitting housings.
69
For Indoor Use only.
70
Because this bulb radiates considerable heat, do not use in enclosed, close fitting fixtures, or in close proximity to people, combustible materials, or substances adversely affected by heat or drying.
For more complete product information visit www.sylvania.com
36
010_INCsf.qxd
11/29/07
8:08 AM
Page 37
SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS
Footnote
Description
71
Even though this bulb may continue to light after the lens or reflector is cracked or broken, it should be replaced as soon as possible since
the pressure filled inner capsule could unexpectedly shatter, creating a risk of personal injury or property damage. In addition, the inner capsule produces ultraviolet radiation that can cause injury to the eyes and skin with prolonged exposure without the blocking effect of the outer
glass bulb.
72
To avoid electric shock and/or skin burns, turn off power and allow bulb to cool before handling or attempting replacement.
73
For indoor or outdoor use where not directly exposed to weather. Exposure to weather may damage the bulb.
74
Use only with ceramic/porcelain sockets and in fixtures rated for this bulb type, including voltage and wattage.
75
Screw bulb firmly but not forcibly into socket to obtain good electrical contact and to avoid damaging bulb and/or socket. Socket condition
may affect bulb life. Replace socket if deterioration of socket or bulb contacts is observed.
76
Due to change from high pressure capsule to low pressure capsule, dimensions have been changed: LCL from 19.5 to 22mm and bulb diameter from 9 to 9.5mm.
77
@ 120 volts, approximate 26 watts, 150 lumens, 5000 hours.
78
Recommended operating position any within 60 degrees of vertically base up or base down.
79
@ 120 volts, approximate 28 watts, 200 lumens, 7500 hours.
80
@ 120 volts, approximate 53 watts, 340 lumens, 12500 hours.
81
@ 120 volts, approximate 66 watts, 500 lumens, 12500 hours.
82
@ 120 volts, approximate 88 watts, 765 lumens, 12500 hours.
83
@ 120 volts, approximate 88 watts, 1020 lumens, 2500 hours.
84
UV Filter Quartz
85
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
86
Operate only in heat resistant sockets
87
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
88
@ 120 volts, approximate 44 watts, 850 lumens, 6000 hours.
89
For use only in fixtures designed specifically for dichroic Reflector Lamps.
90
@ 120 volts, approximate 53 watts, 660 lumens, 6000 hours.
91
Max pin temperature 220 C.
92
Max pin temperature 250 C.
93
Max temperature at lens reflector joint 240 C.
94
Not for use in ceiling fan fixtures
95
For use where seal temperature does not exceed 662F.
96
Per Title 20 Section 1605.3(m) of the California Code of Regulations, this lamp may not be sold or offered for sale in the state of California
for use in Traffic Signals.
97
Board Size MFX Base 1.6mm (0.062") Inside of Board
98
OSRAM Miniwatt lamps for printed circuit boards (the MF series) are designed to work on both inside and outside contact boards and various thickness boards. In order to assure proper electrical contact, be sure to check the thickness of the board and the location of the electrical contacts.
99
@ 120 volts, approximate 33 watts, 270 lumens, 3750 hours.
100
Operate within 25 degrees of vertical base up.
101
@ 120 volts, approximate 53 watts, 490 lumens, 2500 hours.
102
@ 120 volts, approximate 66 watts, 650 lumens, 1875 hours.
103
@ 120 volts, approximate 88 watts, 970 lumens, 1875 hours.
104
@ 120 volts, approximate 46 watts, 560 lumens, 2500 hours.
105
@ 120 volts, approximate 40 watts, 220 lumens, 5000 hours.
106
@ 120 volts, approximate 57 watts, 410 lumens, 5000 hours.
107
Lamps manufactured on or after January 1, 2007 are not for sale in Washington or Oregon.
108
Per Title 20 Section 1605.3(k) of the California Code of Regulations, this lamp may not be sold or offered for sale in the state of California.
109
Lamp may not be operated on a dimmer or DC current
110
Complies with part 15 of FCC rules.
111
Average laboratory life is 200 hours for vacuum cleaner and 600 hours for sewing machine services.
112
Life dependent on service conditions.
113
Operating position 45 degrees base down to horizontal.
For more complete product information visit www.sylvania.com
37
I
N
C
A
N
D
E
S
C
E
N
T
010_INCsf.qxd
11/29/07
8:08 AM
Page 38
SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS
I
N
C
A
N
D
E
S
C
E
N
T
Footnote
Description
114
Use only in fixtures designed to adequately dissipate heat from lamp.
115
3" Circular window.
116
Operation of lamp in any position other than base up may result in some loss of protective coating.
117
A protective shield must be used external to the lamp.
118
In base up operation, heat may eventually deteriorate paper-lined or plastic sockets.
119
Operate only in porcelain or other socket approved for 150 watt PAR lamp.
120
Metal sleeve with approximately 6 " flexible non-insulated leads. Lea ds not included in maximum overall length (M.O.L.).
121
High temperature base. Retards seal deterioration where seal temperature exceeds 650F.
122
Lightly inside frosted and side aluminized; M.O.L. exclusive of spring contact.
123
For use where seal temperature does not exceed 650F.
124
Life at rated voltage and at 650F maximum seal temperature.
125
Usually limited to intermittent burning.
126
Maximum bulb wall temperature 480F.
127
Lamp internally fused.
128
2 1/2" braided lead with lug.
129
Nickel sleeve with 11/4" - 11/2" flexible leads with lug. Leads not included in maximum overall length (M.O.L.)
130
Minimum run. Check nearest OSRAM SYLVANIA Sales Office for details.
131
This lamp should not be used in a location where water may be splashed on it.
132
Package quantity may change. See your OSRAM SYLVANIA Lighting Representative for details.
133
For diesel electric locomotives without voltage regulators.
134
Retrofit for 65BR30/FL, or 75R30/FL.
135
Available in bulk pack.
136
Incandescent lamps operated at less than rated voltage provide a lower light output, longer life, lower color temperature and are less efficient
in terms of lumens per watt.
137
Approximate life for 130 volt tungsten halogen lamps operated at 120 v olts is within the value calculated using the recommended equations
for standard incandescent lamps, as set forth in the IES Handbook, 8th edition. Because of the uncertain nature of the halogen cycle on the
coil when operated at less than rated voltage, life of tungsten halogen lamps varies considerably and unpredictably. OSRAM SYLVANIA does
not recommend operation at other than rated voltage.
138
Nominal wattage - actual may be slightly higher to achieve required light output.
139
A suitable protective shield, screening technique, or both must be used to protect people and surroundings from the possibility of a lamp
shattering and from possible ultraviolet radiation.
140
Standard Clear - UV Filter Quartz
141
Standard Frosted - UV Filter Quartz
142
Starlite Low Pressure - UV Filter Quartz
143
Standard Clear - 24V - UV Filter Quartz - Not suitable for use in open fixtures.
144
Maximum contact to contact tolerance on RSC Base = 1/16"
145
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
146
@120 volts, approximate 22 watts, 130 lumens, 6250 hours
147
@ 120 volts, approximate 26 watts, 100 lumens, 5000 hours
148
@ 120 volts, approximate 28/66/94 watts, 255/800/1060 lumens, 1800 hou rs
149
@ 120 volts, approximate 30 watts, 240 lumens, 6250 hours
150
@ 120 volts, approximate 30 watts, 290 lumens, 3750 hours
151
@ 120 volts, approximate 31 watts, 275 lumens, 5000 hours
152
@ 120 volts, approximate 35 watts, 320 lumens, 6250 hours
153
@ 120 volts, approximate 35 watts, 350 lumens, 3750 hours
154
@ 120 volts, approximate 37 watts, 450 lumens, 7000 hours
155
May not give satisfactory performance if any accessory lighting equipm ent touches the glass bulb.
156
@ 120 volts, approximate 38 watts, 380 lumens, 2250 hours
For more complete product information visit www.sylvania.com
38
010_INCsf.qxd
11/29/07
8:08 AM
Page 39
SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS
Footnote
Description
157
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
158
@ 120 volts, approximate 44 watts, 250 lumens, 5000 hours
159
@ 120 volts, approximate 44 watts, 240 lumens, 5000 hours
160
@ 120 volts, approximate 44 watts, 400 lumens, 2500 hours
161
@ 120 volts, approximate 44 watts, 420 lumens, 5000 hours
162
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
163
@ 120 volts, approximate 46 watts, 460 lumens, 6250 hours
164
@ 120 volts, approximate 46 watts, 540 lumens, 2500 hours
165
@ 120 volts, approximate 46 watts, 600 lumens, 7000 hours
166
When calculations are based on bare lamp lumens, do not use this lumen rating.
167
@ 120 volts, approximate 47/94/141 watts, 545/1275/1820 lumens, 1800 hours
168
@ 120 volts, approximate 53 watts, 420 lumens, 2500 hours
169
@ 120 volts, approximate 53 watts, 495 lumens, 4000 hours
170
@ 120 volts, approximate 53 watts, 650 lumens, 2500 hours
171
@ 120 volts, approximate 53 watts, 645 lumens, 6000 hours
172
@ 120 volts, approximate 56 watts, 725 lumens, 1500 hours
173
@ 120 volts, approximate 57 watts, 540 lumens, 4375 hours
174
@ 120 volts, approximate 59 watts, 660 lumens, 6250 hours
175
@ 120 volts, approximate 59 watts, 780 lumens, 1875 hours
176
@ 120 volts, approximate 63 watts, 900 lumens, 7000 hours
177
Average laboratory life in excess of 5000 hours.
178
@ 120 volts, approximate 66 watts, 425 lumens, 4125 hours
179
@ 120 volts, approximate 66 watts, 620 lumens, 2500 hours
180
@ 120 volts, approximate 66 watts, 685 lumens, 4000 hours
181
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
183
@ 120 volts, approximate 66 watts, 910 lumens, 1875 hours
184
@ 120 volts, approximate 66 watts, 520 lumens, 5000 hours
185
@ 120 volts, approximate 70 watts, 985 lumens, 1125 hours
186
@ 120 volts, approximate 79 watts, 940 lumens, 6250 hours
187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
188
For use only with heat-resisting connector and with bulb supported by bulb rim or metal shell of base.
189
@ 120 volts, approximate 79 watts, 1130 lumens, 1875 hours
190
@ 120 volts, approximate 88 watts, 960 lumens, 2500 hours
191
@ 120 volts, approximate 88 watts, 1100 lumens, 6250 hours
192
@ 120 volts, approximate 88 watts, 1260 lumens, 1875 hours
193
@ 120 volts, approximate 88 watts, 1290 lumens, 1875 hours
194
@ 120 volts, approximate 88 watts, 710 lumens, 5000 hours
195
@ 120 volts, approximate 94 watts, 1455 lumens, 1125 hours
196
@ 120 volts, approximate 105 watts, 850 lumens, 5000 hours
197
@ 120 volts, approximate 105 watts, 1370 lumens, 6000 hours
198
@ 120 volts, approximate 106 watts, 1040 lumens, 5000 hours
I
N
C
A
N
D
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
39
100_cref.qxd
11/29/07
8:11 AM
Page 40
Manufacturers’ Cross Reference Guide (continued)
I
N
C
A
N
D
E
S
C
E
N
T
INCANDESCENT LAMPS
INCANDESCENT LAMPS
SYLVANIA
GE
PHILIPS
SYLVANIA
GE
PHILIPS
4C7/BL/2PK
4C7/W/BL/2PK
10C7/CL
10S11N/CL
15B10/BL/2PK
15B10C/DL/BL
15S14/CL 130V
20T6.5DC/IF
25B10C/DL/BL
25B10/DL/BL
25G16.5C/4M
25G25
25G25/DLSW/RP
25G40
25T10
30/100A21/W/RP
30A15
30R20
40A15/CL/FAN
40A15/SL
40A
40A/34/SS
40A/34/SS/XL
40B10/BL/2PK
40B10C/DL/BL
40B10/W/BL/2PK
40F/CL
40G161/2C
40G25
40G25/DAY/1/6
40G40/W
40S11N/BL
40T10/IF
50/150A21/DLSW/RP
50/150/PS25
50A/RS/SL
60A
60A/52SS
60A/52/SS/XL
60A/CL
60A/DLSW/2PK/RP
60A/GRO
60A/Y/RP
60A21/TS
60B10C/BL/2PK
60B10/DL/BL/2PK
60F/BL
60G25/RP
60G25/DLSW/RP
60K19/DR
60T10/CF
65BR30/DL/FL/RP
65BR30/FL/SS
65BR30/SP/RP
65BR30/SP/SS
65BR30/PK/RP
75A
75A/CL
75A21/RS/SL
75A/67/SS
75A/67/SS/XL
75BR/FL
75ER30
75K19/DR
4C7 CARD 2
4C7/W CD2
10C7 TRAY
10S11N
15CAC/F-CD/2-12
--15S14/GR/CL 130V
20T61/DC/F
25CAC
25CAC/L (120)
--25G25
25G25/W/L/24
25G40
25T10
30/100
30A15-130
30R20-120
40A15/CF CD2
40A15/CF/STG CD2
40A 48PK
40A/34WM
40A/34/WMP/99
40CAM CD/2
40CAC/LL
40CAM/F CD/2
40FM/L
40GC-12PK-120
40G25/L
40G25W/RVL PQ1/6
40G40/W
40S11N/1CARD
40T10/F
--50/150 12PK
50A/RS/CVG 24PK
60A
60A/52WM
60A/52WMP/98
60A/CL 24PK
60A/W/LL-24PK-120
60A/PL 6PK
60A/Y 24PK
--60CAC CD/2 6PK
----60G25 6PK 120V
----60T10/F 24PK
65R30/FL/LL 6PK
75R30/FL/65WM
65R30/SP/LL 6PK
75R30/SP/65WM
65R30/FL/PK
75A
75A/CL 24PK
75A/RT 6PK
75A/67WM
75A/67WMP/99
--75ER30
---
BC-4C7
BC4C7/W
10C7
10S11N
BC15BA9C/CL/LL
15BA9C/4M
--20T61/2DC/IF
--BC25B9-1/2/CL/LL
--25G25/C/LL
--25G40/4M
BC25T10
30/100A/W
30A15
30R20
BC40A15/FAN/CL/LL
40A/TF
40A
40A-34A/EW
40A-34A/99/EW
BC40BA9-1/2/CL/LL
40B101/2/4M
BC40B9-1/2/F/LL
BC40F15/CL/LL
BC40G16-1/2C/CL/LL
40G25/CL/LL
40G25/NTL 6/1
40G40/CL/LL
BC40S11/N TP
BC40T10/IF
--50/150A/DL
50A/RS/TF
60A
60A-52A/EW
--60A/CL
60A/WL
60A/AGRO
60A/Y
K60A19/TS/EW
BC60BA9C/CL/LL
60BA91/24M
BC60F15/CL/LL
60G25/CL/LL
60G25/W/LL
60K19/DL
60T10/64/IF
65BR30/FL/LL55
65BR30/FL55
65BR30/SP20
65BR30/SP20
--75A
75A/CL
75A/RH/TF
75A-67A/EW
75A-67A/99/EW 120
--75ER30
75K19/DL
75R20/RP
100A/90/W/ES/4PK
100A/90/SS/XL
100A
100A/DL/SW/2PK/RP
100A/RS/XL
100A21/VS
100A23/20
100G40
100G40/W
120BR/FL
120BR/SP
120ER40
125BR40
150A21
150A21/135/SS
150A21/99/XL
150PAR46
175W/PAR38/HEAT
200A21
200CL/99/XL
200PS/IF
200PS/CL/99/XL
250BR40
250KBR38/FL
300BR/FL
300/M/CL
300PAR56/MFL
300PAR56/NSP
300PAR56/WFL
300PS35/99/IF/XL
375R40/1
500PAR64/NSP
75R20 6PK
100A/90WM
100A/90WMP/98
100A
--100A/S-130V-24PK
100A/RS 12PK-5
100A23/20
--100G40/W 6PK
120R40/FL/MI-6PK
120R40/SP/MI-6PK
120ER40
125R40
150A
150A/135WM
150Q21/99/IF
150PAR46
175PAR38/HEAT
200A 12PK
200/99
200/IF
200/99
250R40/1
--300R/FL
300M
300PAR56/MFL
300PAR56/NSP
300PAR56/WFL
300/99IF
375R40/1
500PAR64/NSP
75R20/LL
100A-90A/EW
100-90A/99EW
100A
100A/W
--100A/RS/VS
100A23/20
100G40/CL/LL 6/1
100G40/W/LL 6/1
120BR/FL60
120BR/SP20
120ER40
125R40/1
150A
150A-135A/EW
150A/99
--175PAR38/HEAT/CL
200A (A23)
200/99
200/IF
200/99
250R40/1
K250PAR38/FL
300R/FL
300M
300PAR56/MFL
300PAR56/NSP
300PAR56/WFL
300/99IF
375R40/1
500PAR64/NSP
For more complete product information visit www.sylvania.com
40
020_TH_drop.qxd
12/17/07
8:17 AM
Page 41
OSRAM SYLVANIA: THE LEADER IN
HALOGEN LAMP TECHNOLOGY
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Halogen lamps are generally of the 'lamp within a lamp' design. The outer 'lamp' or jacket is made from a heavy walled borosilicate glass.
The inner 'lamp' is the tungsten halogen capsule that is made from either glass or quartz and contains
a filament, lead wires and a halogen gas mixture.
CAPSYLITE IR®
Save energy while still making your merchandise stand out from the crowd. Energy efficient
SYLVANIA CAPSYLITE IR® lamps use a specially designed halogen light source that actually recycles
some of the heat it creates to generate more light for less energy.
Daylight Plus® PAR
The special blue lenses on these halogen PAR lamps help to fill your space with whiter, more natural light
than standard halogen PAR or incandescent lamps.
CAPSYLITE® Soft White Halogen PAR lamps
SYLVANIA CAPSYLITE Soft White Halogen PAR lamps provide the ultimate meeting point between the efficiency
and color of a halogen lamp and the soft, glare free light distribution of an incandescent lamp. They can also
be used as energy saving replacements for incandescent reflector lamps, with the 50W PAR30 Long Neck
lamp replacing a standard 65W BR30 while maintaining the same light levels.
CAPSYLITE® A-Line
Replace a standard incandescent lamp with a CAPSYLITE® A-Line lamp to get a crisp, bright, more natural
light that really lasts. Average rated life for these lamp types is 3,000 to 3,500 hours - up to four times the
ratings of the lamps that they replace!
Soft Glass Halogen Lamps
SYLVANIA soft glass halogen lamps are an outstanding replacement for standard incandescent lamps in any
application. All of the lamps fit standard fixtures, allowing them to be used anywhere to add a new
dimension to home or business lighting
.
OSRAM MINISTAR™
OSRAM MINISTAR lamps represent a revolution in halogen reflector lamp design. Their unique integration
of the reflective surface and the halogen capsule creates the world’s smallest halogen reflector lamps.
TRU-AIM® Low Voltage Lamps
SYLVANIA's complete line of TRU-AIM low voltage lamps provides a wide variety of extremely compact
and highly directional light sources. Choose from standard MR16s (TRU-AIM), aluminized MR16s
(TRU-AIM Brilliant), or top of the line TRU-AIM IR.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 64-68
41
020_TH_drop.qxd
12/3/07
9:55 AM
Page 42
FILAMENTS
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CC-8
CC-2V
CC-6
Axial (AX)
Tranverse (TR)
C-8 Double End
BASES
Ext. Mog.
End Prong
E10
Miniature Screw
E11 Mini can
G4
E26 Medium Skt.
G9
E26 Medium
G53
Recessed Single Contact
RSC
R7s
GY 6.35
Screw Term.
GU4
DC Bayonet
B15d
BA15d
GU5.3
Mogul End Prong
GU10
Med Side Pr.
LAMPS
BT4
BT4T3, T4 BI-PIN
PAR30
PAR56 Mog End Pr
T4 G9.
PAR14
PAR38
PAR16
PAR30LN
PAR36
Medium Skt.
PAR64 Mog End Pr
T4 DC Bayonet T3, T4 Mini Can T3, T4 RSC Double End
For more complete product information visit www.sylvania.com
42
MR16, MR11
PAR38
Medium Side Prong
T10
PAR16 GU10
PAR20
AR70
B11
F17
AR111
BT15
A19
G25
Symbols/Footnotes on page 64-68
020_TH_drop.qxd
12/3/07
9:55 AM
Page 43
HOW TO READ PRODUCT INFORMATION - TUNGSTEN HALOGEN
4
Watts Bulb
40
60
50
Base
Product Symbols &
Number Footnotes
T4
G9
57017
PAR38 E26 Med Skt 14466
PAR30LN E26 Med
14520
Bulb
5,10
Ordering Abbreviation
Pkg Lamp Beam
Volts Qty Finish Type
Avg
Class & Rated Approx
Beam LCL MOL
Filament Life (hrs) Lumens CBCP Angle (in) (in)
40T4/G9/F/BL
120 10 Frosted
C, CC-2V 2000
10,11 60PAR/CAP/IR/FL30 120 15
Flood
CC-8
3000
10,19,20 50PAR30LN/HAL/NFL25 120 15
Narrow FloodCC-8
2500
480
1110
660
3600 30
2300 25
|
|
|
1.00 1.88
5.31
4.63
Describes the shape of the bulb followed by the bulb’s major diameter given in eighths of an inch.
See page 42: Halogen Lamps.
See page 42: Base Identification.
All symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and
footnotes are at the end of the halogen section on page 64.
Applies only to non-reflector type lamps, usually either clear or frosted.
Applies only to reflector type lamps. Describes the beam angle qualitatively as either a spot or a flood, etc.
Base
Symbols &
Footnotes
Lamp Finish
Beam Type
How to Read Ordering Abbreviations
40T4/G9/F/BL
40
T4/G9
F
BL
60PAR/CAP/IR/FL30
60
Nominal lamp wattage
PAR Bulb shape PAR38
CAP CAPSYLITE lamp
IR
Infrared conserving capsule
FL30 Flood beam 30 degrees
Nominal lamp wattage
T4 lamp with G9 base
Frosted finish
Blister Card Package
50PAR30LN/HAL/NFL25
50
Nominal lamp wattage
PAR30LN Bulb shape PAR30 Long Neck
HAL
Halogen lamp
NFL25
Narrow Flood beam 25 degrees
ANSI BEAM ANGLE DESIGNATION
Beam angles for reflector lamps are designated to conform with ANSI C78.379 -Classification of the Beam Patterns of Reflector Lamps. For
beam angles less than 13°, beam angles are rounded to the nearest whole number. For beam angles between 13° and 50°, values are rounded to the nearest 5°. For beam angles 50° and greater, the value is rounded to the nearest 10°. As an example, a family of lamps with an
average beam angle of 13° is classified as 15°, and a family of lamps with an average beam angle of 54° would be classified as 50°.
LIFE RATING
The average rated life for 130V tungsten halogen lamps operated at 120V is conservatively estimated to be approximately 2 times the life
when operated at 130V.
ANSI CODE REFERENCE GUIDE
ANSI ITEM
CODE NO.
BAB
EHM
EHT
ESL
ESM
ESN
ESP
ESR
ESS
ESX
ETB
ETC
58301
58998
58762
58738
58763
58761
58742
58755
58720
58300
58753
58741
L.L. ORDERING
ABBREVIATION
(EXCEPT VOLTS)
20MR16/T/FL35/C
300T3Q/CL
250Q/CL/MC
150Q/CL/MC
250Q/MC
100Q/CL/MC
150Q/CL/DC/1
100Q/CL/DC
250Q/CL/DC
20MR16/T/SP10/C
250Q/DC
150Q/CL/DC
VOLTS
ANSI ITEM
CODE NO.
12
120
120
120
120
120
120
120
120
12
120
120
ETD
ETF
ETG
ETH
EVR
EXN
EXT
EXZ
EYV
EYW
EYX
FCL
For more complete product information visit www.sylvania.com
58757
58737
58735
58736
58766
58309
58307
58308
58768
58756
58767
58996
L.L. ORDERING
ABBREVIATION
(EXCEPT VOLTS)
100Q/DC
150Q/DC
150Q/CL/MC/2
150Q/MC
500Q/CL/MC
50MR16/T/FL35/C
50MR16/T/SP10/C
50MR16/T/NFL25/C
500Q/MC
500Q/CL/MC
500Q/MC
500T3Q/CL
VOLTS
120
120
120
120
120
12
12
12
130
130
120
120
ANSI ITEM
CODE NO.
FMW
FNV
FPA
FPB
FPC
FRB
FTB
FTD
FTE
FTH
58305
58310
58311
58313
58312
58303
55133
55134
55135
55136
L.L. ORDERING
ABBREVIATION
(EXCEPT VOLTS)
35MR16/T/FL35/C
50MR16/T/WFL60/C
65MR16/T/SP10/C
65MR16/T/FL35/C
65MR16/T/NFL25/C
35MR16/T/SP10/C
20MR11/T/SP10/C
20MR11/T/FL35/C
35MR11/T/SP10/C
35MR11/T/FL35/C
VOLTS
12
12
12
12
12
12
12
12
12
12
Symbols/Footnotes on page 64-68
43
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_drop.qxd
12/17/07
8:17 AM
Page 44
TUNGSTEN HALOGEN BRAND NAME GUIDE
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
SYLVANIA
GE*
PHILIPS**
CAPSYLITE IR®
CAPSYLITE®
CAPSYLITE® COOL-LUX
CAPSYLITE® Designer 16
CAPSYLITE® A-Line
Daylight Plus® PAR
TRU-AIM IR®
TRU-AIM TITAN®
TRU-AIM BRILLIANT®
TRU-AIM® Standard MR16
TRU-AIM® MR11
Softwhite Halogen PAR
STANDARD Bi-Pin
STARLITE Bi-Pin
Double End
SUPER Q
Large PAR
Tubular Halogen T10
AR111
AR70
Soft Glass Halogen
Softwhite Halogen PAR
Osram MINISTAR
HIR PAR
HALOGEN PLUS / HALOGEN Compact
Cool Beam PAR
HALOGEN Compact PAR16
A-Line
Reveal
PRECISE COVERGLASS IR MR16
ConstantColor Precise Cover Glass
Energy Advantage IR
Halogen WISO Reflector
Cool Beam Reflector
Halogen PAR16
HALOPAR16
Natural
Halogen MR Energy Advantage IR
Halogen MR Long Life
Halogen MR Aluminum
Halogen MR
Halogen MRC-11
Decostar 51 IRC
Decostar 51 TITAN
Decostar 51 ALU
Decostar 51
Decostar 35
Halogen Low Voltage Capsule
Halogen Double-Ended Linear
Halogen Single-Ended
HALOSTAR Standard
HALOSTAR STARLITE
HALOLINE
HALOLUX Ceram
ALU Line PRO 111
Closed Aluminum Reflector
Halogena
HALOLUX Ceram
HALOSPOT 111
HALOSPOT 70
HALOLUX BT
Standard MR16
STANDARD MR11
Quartz Halogen
Quartzline
Halogen
Halogen
T10
AR111
A-Line / Decorative
OSRAM***
HALOPAR
MINISTAR
* Trademark or registered trademarks of General Electric Company. ** Trademark or registered trademarks of Philips. *** Trademark or registered trademarks of OSRAM.
For weight and measurement information, please visit www.sylvania.com
For more complete product information visit www.sylvania.com
44
Symbols/Footnotes on page 64-68
020_TH_print.qxd
12/17/07
8:13 AM
Page 45
A19
CAPSYLITE® A-LINE
Suitable for use in unshielded fixtures.
15
Watts Bulb
Base
Product Symbols &
Number Footnotes
42
E26 Med
18907
A19
18908
137,154
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
42A/HAL/F
120
12
Inside
Frost
C,CC-8
3500
580
2750
3.13
4.38
42A/HAL/F
130
12
Inside
Frost
C,CC-8
3500
580
2750
3.13
4.38
|
|
|
@ 120 volts, approximate 37 watts, 450 lumens, 7000 hours
50
A19
E26 Med
18968
50A/HAL/CRYSTAL
120
12
Crystal
C,CC-8
2500
860
2825
3.13
4.38
52
A19
E26 Med
18921
52A/HAL/F
120
12
Inside
Frost
C,CC-8
3500
770
2775
3.13
4.38
52A/HAL/F
130
12
Inside
Frost
C,CC-8
3500
770
2775
3.13
4.38
18922
137,165
@ 120 volts, approximate 46 watts, 600 lumens, 7000 hours
60
72
A19
A19
E26 Med
E26 Med
18998
60A/HAL/CL/CLAM
120
6
Clear
C,CC-8
3000
965
2850
3.13
4.38
18942
60A/HAL/CRYSTAL/CLAM
120
6
Crystal
C,CC-8
3000
965
2850
3.13
4.38
18960
60A/HAL/F
120
12
Inside
Frost
C,CC-8
3000
965
2850
3.13
4.38
18999
60A/HAL/F/CLAM
120
6
Inside
Frost
C,CC-8
3000
960
2850
3.13
4.38
18937
72A/HAL/F
120
12
Inside
Frost
C,CC-8
3500
1150
2825
3.13
4.38
72A/HAL/F
130
12
Inside
Frost
C,CC-8
3500
1150
2825
3.13
4.38
18938
137,176
@ 120 volts, approximate 63 watts, 900 lumens, 7000 hours
75
100
150
A19
A19
A19
E26 Med
E26 Med
E26 Med
19000
75A/HAL/CL/CLAM
120
6
Clear
C,CC-8
3000
1330
2875
3.13
4.38
18969
75A/HAL/CRYSTAL
120
12
Crystal
C,CC-8
3000
1330
2875
3.13
4.38
18906
75A/HAL/CRYSTAL/CLAM
120
6
Crystal
C,CC-8
3000
1330
2875
3.13
4.38
18965
75A/HAL/F
120
12
Inside
Frost
C,CC-8
3000
1315
2875
3.13
4.38
18997
75A/HAL/F/CLAM
120
6
Inside
Frost
C,CC-8
3000
1315
2875
3.13
4.38
19003
100A/HAL/CL/CLAM
120
6
Clear
C,CC-8
3000
1800
2900
3.13
4.38
18911
100A/HAL/CRYSTAL/CLAM
120
6
Crystal
C,CC-8
3000
1800
2900
3.13
4.31
18970
100A/HAL/F
120
12
Inside
Frost
C,CC-8
3000
1800
2900
3.13
4.38
18905
100A/HAL/F/CLAM
120
6
Inside
Frost
C,CC-8
3000
1800
2900
3.13
4.38
18912
150A/HAL/CLAM
120
6
Inside
Frost
C,CC-8
3000
3000
2975
3.13
4.31
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 64-68
45
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
12/3/07
BT15
9:56 AM
B11
Page 46
G25
F17
T10
HALOGEN BT15
Suitable for use in unshielded fixtures.
15
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
73,74,84,
60BT15/HAL/CL/BL
120
10
Clear
C,CC-8
3000
820
2900
2.94
4.63
72,73,74,
60BT15/HAL/W/BL
120
10
White
C,CC-8
3000
760
2900
2.94
4.63
75BT15/HAL/W/BL
120
10
White
C,CC-8
3000
1010
2900
2.94
4.63
100BT15/HAL/W/BL
120
10
White
C,CC-8
3000
1500
2900
2.94
4.63
150BT15/HAL/W/BL
120
10
White
C,CC-8
3000
2400
2900
2.94
4.63
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
60
E26 Med
18864
BT15
145
18865
84,145
75
BT15
E26 Med
18866
72,73,74,
84,145
100
BT15
E26 Med
18867
72,73,74,
84,145
150
BT15
E26 Med
18868
72,73,74,
84,145
|
|
|
HALOGEN DÉCOR LAMPS
Suitable for use in unshielded fixtures.
15
Watts Bulb
Base
Product Symbols &
Number Footnotes
25
B11
Candelabra
13269
73,74,145
25B11C/T/HAL/BL
120
6
Clear
C,CC-2V
3000
180
2900
2.60
4.69
40
B11
Candelabra
13334
73,74,145
40B11C/HAL/BL
120
6
Clear
C,CC-2V
3000
380
2900
2.60
4.56
G25
E26 Med
13998
73,74,145
40G25/HAL
120
6
Clear
C,CC-2V
3000
380
2900
3.25
4.44
G25
E26 Med
14000
73,74,145
60G25/HAL
120
6
Clear
C,CC-2V
3000
630
2900
3.25
4.44
F17
E26 Med
13879
60F/HAL/DAY/CLAM
120
6
Crystal
C,CC-8
3000
960
2850
3.00
4.50
60
|
|
|
TUBULAR HALOGEN T10
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility
of a lamp shattering.
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
75
E26 Med
18846
139
75T10/HAL/CL
120
12
Clear
C,CC-2V
2000
1100
2900
2.94
4.13
18847
139
75T10/HAL/F
120
12
Frosted
C,CC-2V
2000
1050
2900
2.94
4.13
18848
139
100T10/HAL/CL
120
12
Clear
C,CC-2V
2000
1500
2900
2.94
4.13
18849
139
100T10/HAL/F
120
12
Frosted
C,CC-2V
2000
1430
2900
2.94
4.13
18850
46,139
150T10/HAL/CL
120
12
Clear
C,CC-2V
2000
2500
2900
2.94
4.13
18851
46,139
150T10/HAL/F
120
12
Frosted
C,CC-2V
2000
2400
2900
2.94
4.13
18852
46,139
230T10/HAL/CL
120
12
Clear
C,CC-2V
2000
4200
2900
2.94
4.13
18853
46,139
230T10/HAL/F
120
12
Frosted
C,CC-2V
2000
4000
2900
2.94
4.13
100
150
230
T10
T10
T10
T10
E26 Med
E26 Med
E26 Med
For more complete product information visit www.sylvania.com
46
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
PAR20
9:56 AM
Page 47
PAR30LN
PAR38
PAR14
PAR16 GU10
DAYLIGHT PLUS® PAR LAMPS
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
E26 Med
15226
PAR20
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50PAR20/HAL/DAY/NFL
120 6
NFL
C,CC-8
2500
500
2900
1000
30
3.25
50PAR30LN/HAL/DAY/WFL
120 6
WFL
C,CC-8
2500
550
2900
550
50
4.63
75PAR30LN/HAL/DAY/WFL
120 6
WFL
C,CC-8
2500
1000
3000
1000
50
4.63
50PAR38/CAPIR/DAY/WSP12
120 15
WSP
C,CC-8
3000
700
2925
7000
12
5.31
50PAR38/CAPIR/DAY/FL30
120 15
FL
C,CC-8
3000
700
2925
1800
30
5.31
50PAR38/HAL/DAY/FL
120 6
FL
C,CC-8
2500
540
2900
1550
30
5.31
75PAR38/HAL/DAY/FL
120 6
FL
C,CC-8
2500
960
3000
2800
30
5.31
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50PAR20/HAL/SW
120 6
FL
C,CC-8
2500
525
2850
525
40
3.25
50PAR30LN/HAL/SW
120 6
FL
C,CC-8
2500
600
2850
450
50
4.63
75PAR30LN/HAL/SW
120 6
FL
C,CC-8
2500
1050
2900
700
50
4.63
50PAR38/HAL/SW
120 6
FL
C,CC-8
2500
600
2850
550
50
5.31
75PAR38/HAL/SW
120 6
FL
C,CC-8
2500
980
2900
1300
50
5.31
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
35PAR14/HAL/FL/RP
120 6
C,CC-8
50
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
118
PAR30LN
E26 Med
15227
73,118
75
PAR30LN
E26 Med
15228
73,118
50
PAR38
E26 Med Skt
13973
43,47,72,118
15259
43,47,72,118
15229
118
75
PAR38
E26 Med Skt
15230
118
|
|
|
SOFTWHITE HALOGEN PAR LAMPS
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
E26 Med
13260
PAR20
43,118
PAR30LN
E26 Med
13259
43,73,118,134
75
PAR30LN
E26 Med
13258
50
PAR38
E26 Med Skt
15236
43,73,118
43,72,118
75
PAR38
E26 Med Skt
13257
43,72,118
|
|
|
CAPSYLITE® PAR14 LAMPS
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
35
E26 Med
15364
PAR14
41,118
FL
2000
450
2775
200
|
|
|
2.44
CAPSYLITE® PAR16 LAMPS
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
35
GU10
13256
72
35PAR16/HAL/GU10/FL/BL3
120 18
FL
C,CC-8
3000
280
2750
500
30
2.25
59076
72
35PAR16/HAL/GU10/FL/BL
120 6
FL
C,CC-8
3000
280
2750
500
30
2.25
PAR16
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 64-68
47
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
PAR16 GU10
12/3/07
9:56 AM
PAR16 GU10
Page 48
PAR20
CAPSYLITE® PAR16 LAMPS
Suitable for use in unshielded fixtures.
16
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
GU10
59061
72
50PAR16/HAL/GU10/FL/BL3
120 18
FL
C,CC-8
3000
450
2800
800
30
2.25
59075
72
50PAR16/HAL/GU10/FL/BL
120 6
FL
C,CC-8
3000
450
2800
800
30
2.25
59024
68
50PAR16/HAL/GU10/FL40
120 10
FL
C,CC-2V 1000
400
2950
640
40
2.08
59020
68
50PAR16/HAL/GU10/FL/CLAM
120 6
FL
C,CC-2V 1000
400
2950
640
40
2.08
59032
69,118
60PAR16/HAL/NSP10
120 15
NSP
C,CC-8
2000
650
2850
5000
10
2.88
59037
69,118
60PAR16/HAL/NSP10/RP
120 6
NSP
C,CC-8
2000
650
2850
5000
10
2.88
69,118,137,
60PAR16/HAL/NSP10
130 15
NSP
C,CC-8
2000
650
2850
5000
10
2.88
60
PAR16
PAR16
E26 Med
59040
169
|
|
|
@ 120 volts, approximate 53 watts, 495 lumens, 4000 hours
59030
69,118
60PAR16/HAL/NFL30
120 15
NFL
C,CC-8
2000
650
2850
1300
30
2.88
59031
69,118
60PAR16/HAL/NFL30/RP
120 6
NFL
C,CC-8
2000
650
2850
1300
30
2.88
69,118,137,
60PAR16/HAL/NFL30
130 15
NFL
C,CC-8
2000
650
2850
1300
30
2.88
59038
169
@ 120 volts, approximate 53 watts, 495 lumens, 4000 hours
75
PAR16
E26 Med
59036
59044
69,118
75PAR16/HAL/NSP10
120 15
NSP
C,CC-8
2000
900
2900
7500
10
2.88
69,118,137,
75PAR16/HAL/NSP10
130 15
NSP
C,CC-8
2000
900
2900
7500
10
2.88
180
@ 120 volts, approximate 66 watts, 685 lumens, 4000 hours
59034
69,118
75PAR16/HAL/NFL30
120 15
NFL
C,CC-8
2000
900
2900
1900
30
2.88
59033
69,118
75PAR16/HAL/NFL30/RP
120 6
NFL
C,CC-8
2000
900
2900
1900
30
2.88
69,118,137,
75PAR16/HAL/NFL30
130 15
NFL
C,CC-8
2000
900
2900
1900
30
2.88
59042
180
@ 120 volts, approximate 66 watts, 685 lumens, 4000 hours
®
CAPSYLITE IR PAR20
Halogen PAR lamp with infrared reflective coating on the lamp capsule. Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
40
E26 Med
14164
PAR20
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
40PAR20/CAPIR/NSP10
120 15
NSP
C,CC-8
4000
510
2750
4200
10
3.25
40PAR20/CAPIR/NFL30
120 15
NFL
C,CC-8
4000
510
2750
1100
30
3.25
40PAR20/CAPIR/WFL40
120 15
WFL
C,CC-8
4000
510
2750
800
40
3.25
43,47,118
14166
43,47,118
14130
43,47,118
For more complete product information visit www.sylvania.com
48
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
PAR20
9:56 AM
Page 49
PAR30
CAPSYLITE® PAR20
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
35
E26 Med
14467
PAR20
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
35PAR20/HAL/NSP10
120 15
NSP
C,CC-8
2500
360
2775
3000
10
3.25
35PAR20/HAL/NFL30
120 15
NFL
C,CC-8
2500
360
2775
800
30
3.25
35PAR20/HAL/NFL30
130 15
NFL
C,CC-8
2500
360
2775
800
30
3.25
43,118
14464
43,118
14459
43,118,137,151
|
|
|
@ 120 volts, approximate 31 watts, 275 lumens, 5000 hours
14506
35PAR20/HAL/WFL40
120 15
WFL
C,CC-8
2500
360
2775
500
40
3.25
35PAR20/HAL/WFL40
130 15
WFL
C,CC-8
2500
360
2775
500
40
3.25
43,118
14461
43,118,137,151
@ 120 volts, approximate 31 watts, 275 lumens, 5000 hours
50
PAR20
E26 Med
14500
50PAR20/HAL/NSP10
120 15
NSP
C,CC-8
2500
550
2850
4600
10
3.25
50PAR20/HAL/NSP10
130 15
NSP
C,CC-8
2500
550
2850
4600
10
3.25
43,118
14528
43,118,137,161
@ 120 volts, approximate 44 watts, 420 lumens, 5000 hours
14502
50PAR20/HAL/NFL30
120 15
NFL
C,CC-8
2500
550
2850
1200
30
3.25
50PAR20/HAL/NFL30/RP
120 6
NFL
C,CC-8
2500
550
2850
1200
30
3.25
50PAR20/HAL/NFL30
130 15
NFL
C,CC-8
2500
550
2850
1200
30
3.25
NFL
C,CC-8
2500
550
2850
1200
30
3.25
WFL
C,CC-8
2500
550
2850
900
40
3.25
43,118
14173
43,118
14529
43,118,137,161
@ 120 volts, approximate 44 watts, 420 lumens, 5000 hours
15662
50PAR20/HAL/NFL30/CVP
130 6
43,118,137,161
@ 120 volts, approximate 44 watts, 420 lumens, 5000 hours
14700
50PAR20/HAL/WFL40
120 15
43,118
CAPSYLITE IR® PAR30
Halogen PAR lamp with infrared reflective coating on the lamp capsule. Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
40
E26 Med
13968
PAR30
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
40PAR30/CAPIR/NSP9
120 15
NSP
C,CC-8
4000
610
2750
8100
9
3.63
40PAR30/CAPIR/NFL25
120 15
NFL
C,CC-8
4000
610
2750
2100
25
3.63
40PAR30/CAPIR/FL40
120 15
FL
C,CC-8
4000
610
2750
1200
40
3.63
50PAR30/CAPIR/NSP9
120 15
NSP
C,CC-8
3000
900
2825
13000
9
3.63
50PAR30/CAPIR/NFL25
120 15
NFL
C,CC-8
3000
900
2825
2900
25
3.63
50PAR30/CAPIR/NFL25
130 15
NFL
C,CC-8
3000
900
2825
2900
25
3.63
43,47,118
13969
43,47,118
13970
43,47,118
50
PAR30
E26 Med
14355
43,47,118,137
14354
43,47,118
14132
43,47,87,118
|
|
|
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
14714
50PAR30/CAPIR/FL40
120 15
FL
C,CC-8
3000
900
2825
1600
40
3.63
50PAR30/CAPIR/FL40
130 15
FL
C,CC-8
3000
900
2825
1600
40
3.63
43,47,118
14131
43,47,87,118,137
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 64-68
49
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
12/3/07
PAR30
9:56 AM
Page 50
PAR30LN
CAPSYLITE® PAR30
Suitable for use in unshielded fixtures.
16
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
E26 Med
14526
PAR30
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50PAR30/HAL/NSP9
120 15
NSP
C,CC-8
2500
660
2850
8800
9
3.63
50PAR30/HAL/NSP9
130 15
NSP
C,CC-8
2500
660
2850
8800
9
3.63
43,118
14530
43,118,137,162
|
|
|
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14527
50PAR30/HAL/NFL25
120 15
NFL
C,CC-8
2500
660
2850
2300
25
3.63
50PAR30/HAL/NFL25
130 15
NFL
C,CC-8
2500
660
2850
2300
25
3.63
43,118
14531
43,118,137,162
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14710
50PAR30/HAL/FL40
120 15
FL
C,CC-8
2500
660
2850
1300
40
3.63
50PAR30/HAL/FL40
130 15
FL
C,CC-8
2500
660
2850
1300
40
3.63
43,118
14533
43,118,137,162
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
60
PAR30
E26 Med
14332
60PAR30/HAL/NSP9
120 15
NSP
C,CC-8
3000
860
2875
12000
9
3.63
60PAR30/HAL/NFL25
120 15
NFL
C,CC-8
3000
860
2875
2775
25
3.63
60PAR30/HAL/NFL25
130 15
NFL
C,CC-8
3000
860
2875
2775
25
3.63
FL
C,CC-8
3000
860
2875
1550
40
3.63
43,118
14333
43,118
14090
43,90,118,137
@ 120 volts, approximate 53 watts, 660 lumens, 6000 hours.
14084
60PAR30/HAL/FL40
130 15
43,90
@ 120 volts, approximate 53 watts, 660 lumens, 6000 hours.
75
PAR30
E26 Med
14604
75PAR30/HAL/NSP9
120 15
NSP
C,CC-8
2500
1130
2900
15400
9
3.63
75PAR30/HAL/NSP9
130 15
NSP
C,CC-8
2500
1130
2900
15400
9
3.63
43,118
14628
43,118,137,182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14603
75PAR30/HAL/NFL25
120 15
NFL
C,CC-8
2500
1130
2900
4000
25
3.63
75PAR30/HAL/NFL25
130 15
NFL
C,CC-8
2500
1130
2900
4000
25
3.63
43,118
14627
43,118,137,182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14606
75PAR30/HAL/FL40
120 15
FL
C,CC-8
2500
1130
2900
2100
40
3.63
75PAR30/HAL/FL40
130 15
FL
C,CC-8
2500
1130
2900
2100
40
3.63
43,118
14629
43,118,137,182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
®
CAPSYLITE PAR30 LONG NECK
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
35
E26 Med
14759
PAR30LN
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
35PAR30LN/HAL/NSP9
120 15
NSP
C,CC-8
2500
450
2775
4500
10
4.63
35PAR30LN/HAL/WFL50
120 15
WFL
C,CC-8
2500
450
2775
450
50
4.63
50PAR30LN/HAL/NSP9
120 15
NSP
C,CC-8
2500
660
2850
7000
10
4.63
43,73,118
14764
43,73,118
50
PAR30LN
E26 Med
14509
43,73,118,134
For more complete product information visit www.sylvania.com
50
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
9:56 AM
PAR30LN
Page 51
PAR38
CAPSYLITE® PAR30 LONG NECK
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
E26 Med
14482
PAR30LN
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50PAR30LN/HAL/NSP9
130 15
NSP
C,CC-8
2500
660
2850
7000
10
4.63
43,73,118,134,137,162
|
|
|
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14520
50PAR30LN/HAL/NFL25
120 15
NFL
C,CC-8
2500
660
2850
2100
25
4.63
50PAR30LN/HAL/NFL
120 6
NFL
C,CC-8
2500
660
2850
2100
25
4.63
50PAR30LN/HAL/NFL25
130 15
NFL
C,CC-8
2500
660
2850
2100
25
4.63
43,73,118,134
14822
43,73,118,134
14478
43,73,118,134,137,162
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14537
50PAR30LN/HAL/WFL50
120 15
WFL
C,CC-8
2500
660
2850
660
50
4.63
50PAR30LN/HAL/WFL
120 6
WFL
C,CC-8
2500
660
2850
660
50
4.63
50PAR30LN/HAL/WFL50
130 15
WFL
C,CC-8
2500
660
2850
660
50
4.63
WFL
C,CC-8
2500
660
2850
660
50
4.63
43,73,118,134
14536
43,73,118,134
14486
43,73,118,134,137,162
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
15419
50PAR30LN/HAL/WFL50/CVP
130 6
43,73,118,134,137,162
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
75
PAR30LN
E26 Med
14786
75PAR30LN/HAL/NSP9
120 15
NSP
C,CC-8
2500
1130
2950
12000
10
4.63
75PAR30LN/HAL/NSP9
130 15
NSP
C,CC-8
2500
1130
2900
12000
10
4.63
43,73,118
14777
43,73,118,137,182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14769
75PAR30LN/HAL/NFL25
120 15
NFL
C,CC-8
2500
1130
2900
3600
25
4.63
75PAR30LN/HAL/NFL
120 6
NFL
C,CC-8
2500
1130
2900
3600
25
4.63
75PAR30LN/HAL/NFL25
130 15
NFL
C,CC-8
2500
1130
2900
3600
25
4.63
43,73,118
14824
43,73,118
14778
43,73,118,137,182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14768
75PAR30LN/HAL/WFL50
120 15
WFL
C,CC-8
2500
1130
2900
1100
50
4.63
75PAR30LN/HAL/WFL
120 6
WFL
C,CC-8
2500
1130
2900
1100
50
4.63
75PAR30LN/HAL/WFL50
130 15
WFL
C,CC-8
2500
1130
2900
1100
50
4.63
WFL
C,CC-8
2500
1130
2900
1100
50
4.63
43,73,118
14823
43,73,118
14785
43,73,118,137,182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
15418
75PAR30LN/HAL/WFL50/CVP
130 6
43,73,118,137,182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
®
CAPSYLITE IR PAR38
Halogen PAR lamp with infrared reflective coating on the lamp capsule. Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
E26 Med Skt
13973
PAR38
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50PAR38/CAPIR/DAY/WSP12
120 15
WSP
C,CC-8
3000
700
2875
7000
12
5.31
50PAR38/CAPIR/DAY/FL30
120 15
FL
C,CC-8
3000
700
2875
1800
30
5.31
43,47,72,118
15259
43,47,72,118
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 64-68
51
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 52
PAR38
CAPSYLITE IR® PAR38
Halogen PAR lamp with infrared reflective coating on the lamp capsule. Suitable for use in unshielded fixtures.
16
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
E26 Med Skt
14136
PAR38
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50PAR38/CAPIR/SP9
120 15
SP
C,CC-8
3000
850
2825
14000
9
5.31
50PAR38/CAPIR/SP9
130 15
SP
C,CC-8
3000
850
2825
14000
9
5.31
43,47,72,118
14124
43,47,72,88,118,137
|
|
|
@ 120 volts, approximate 44 watts, 650 lumens, 6000 hours.
14138
50PAR38/CAPIR/NFL25
120 15
NFL
C,CC-8
3000
850
2825
3000
25
5.31
50PAR38/CAPIR/NFL25
130 15
NFL
C,CC-8
3000
850
2825
3000
25
5.31
43,47,72,118
14125
43,47,72,88,118,137
@ 120 volts, approximate 44 watts, 650 lumens, 6000 hours.
60
PAR38
E26 Med Skt
14485
60PAR38/CAPIR/SP9
120 15
SP
C,CC-8
3000
1110
2850
20000
9
5.31
60PAR38/CAPIR/SP9
130 15
SP
C,CC-8
3000
1110
2850
20000
9
5.31
43,47,72,118
14716
43,47,72,85,118,137
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
14360
60PAR38/CAPIR/WSP12
120 15
WSP
C,CC-8
3000
1110
2850
12000
12
5.31
60PAR38/CAPIR/NFL25
120 15
NFL
C,CC-8
3000
1110
2850
4000
25
5.31
60PAR38/CAPIR/FL30
120 15
FL
C,CC-8
3000
1110
2850
3600
30
5.31
60PAR38/CAPIR/FL30
130 15
FL
C,CC-8
3000
1110
2850
3600
30
5.31
43,47,72,118
14442
43,47,72,118
14466
43,47,72,118
14715
43,47,72,85,118,137
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
80
PAR38
E26 Med Skt
14347
80PAR38/CAPIR/SP10
120 12
SP
C,CC-8
3000
1500
2900
25000
10
5.31
80PAR38/CAPIR/FL25
120 12
FL
C,CC-8
3000
1500
2900
5500
25
5.31
100PAR38/CAPIR/SP10
120 12
SP
C,CC-8
3000
2070
2900
29000
10
5.31
100PAR38/CAPIR/NFL25
120 12
NFL
C,CC-8
3000
2070
2900
6300
25
5.31
100PAR38/CAPIR/FL40
120 12
FL
C,CC-8
3000
2070
2900
3400
40
5.31
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
45PAR38/HAL/SP9
120 15
SP
C,CC-8
2500
560
2825
10000
9
5.31
45PAR38/HAL/SP
120 6
SP
C,CC-8
2500
560
2825
10000
9
5.31
45PAR38/HAL/SP9
130 15
SP
C,CC-8
2500
560
2825
10000
9
5.31
47,72,118
14327
47,72,118
100
PAR38
E26 Med Skt
14324
47,72,118
14319
47,72,118
14311
47,72,118
CAPSYLITE® PAR38
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
45
E26 Med Skt
14590
PAR38
43,72,118
15538
43,72,118
14593
43,72,118,137,157
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
14589
45PAR38/HAL/WSP12
120 15
WSP
C,CC-8
2500
560
2825
6300
12
5.31
45PAR38/HAL/WSP12
130 15
WSP
C,CC-8
2500
560
2825
6300
12
5.31
43,72,118
14592
43,72,118,137,157
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
For more complete product information visit www.sylvania.com
52
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 53
PAR38
CAPSYLITE® PAR38
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
45
E26 Med Skt
14588
PAR38
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
45PAR38/HAL/FL30
120 15
FL
C,CC-8
2500
560
2825
1500
30
5.31
45PAR38/HAL/FL
120 6
FL
C,CC-8
2500
560
2825
1500
30
5.31
45PAR38/HAL/FL30
130 15
FL
C,CC-8
2500
560
2825
1500
30
5.31
WFL
C,CC-8
2500
560
2825
700
50
5.31
43,72,118
15537
43,72,118
14591
43,72,118,137,157
|
|
|
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
14010
45PAR38/HAL/WFL50
130 15
43,72,118,137,157
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
47
PAR38
E26 Med Skt
15404
47PAR38/HAL/DL/SP9
120 15
SP
C,CC-8
6000
570
2750
10000
9
5.31
47PAR38/HAL/DL/FL30
120 15
FL
C,CC-8
6000
570
2750
1500
30
5.31
50PAR38/HAL/SP9
120 6
SP
C,CC-8
2500
650
2850
10500
9
5.31
50PAR38/HAL/FL30
120 6
FL
C,CC-8
2500
650
2850
1850
30
5.31
60PAR38/HAL/SP9
120 15
SP
C,CC-8
3000
850
2875
16000
9
5.31
60PAR38/HAL/SP9
130 15
SP
C,CC-8
3000
850
2875
16000
9
5.31
43,72,118,137
15405
43,72,118,137
50
PAR38
E26 Med Skt
15521
43,72,118,137
15520
43,72,118,137
60
PAR38
E26 Med Skt
14469
43,72,118
14449
43,72,118,137,171
@ 120 volts, approximate 53 watts, 645 lumens, 6000 hours
14472
60PAR38/HAL/NFL25
120 15
NFL
C,CC-8
3000
850
2875
3700
25
5.31
60PAR38/HAL/FL30
120 15
FL
C,CC-8
3000
850
2875
2500
30
5.31
60PAR38/HAL/FL30
130 15
FL
C,CC-8
3000
850
2875
2500
30
5.31
118
14468
43,72,118
14448
43,72,118,137,171
@ 120 volts, approximate 53 watts, 645 lumens, 6000 hours
63
PAR38
E26 Med Skt
15421
63PAR38/HAL/DL/SP9
120 15
SP
C,CC-8
6000
800
2800
14000
9
5.31
75PAR38/HAL/SP9
120 15
SP
C,CC-8
2500
1060
2900
19200
9
5.31
75PAR38/HAL/SP/RP
120 6
SP
C,CC-8
2500
1060
2900
19200
9
5.31
75PAR38/HAL/SP9
130 15
SP
C,CC-8
2500
1060
2900
19200
9
5.31
43,72,118
75
PAR38
E26 Med Skt
14514
43,72,118
14854
43,72,118
14516
43,72,118,137,181
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
14510
75PAR38/HAL/WSP12
120 15
WSP
C,CC-8
2500
1060
2900
12300
12
5.31
75PAR38/HAL/FL30
120 15
FL
C,CC-8
2500
1060
2900
3150
30
5.31
75PAR38/HAL/FL/RP
120 6
FL
C,CC-8
2500
1060
2900
3150
30
5.31
75PAR38/HAL/FL30
130 15
FL
C,CC-8
2500
1060
2900
3150
30
5.31
FL
C,CC-8
2500
1060
2900
3150
30
5.31
43,72,118
14513
43,72,118
14853
43,72,118
14515
43,72,118,137,181
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
14446
75PAR38/HAL/FL/CVP
130 6
43,72,118,137,181
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 64-68
53
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
PAR38
12/3/07
9:56 AM
Page 54
PAR38 Med Side Prong
CAPSYLITE® PAR38
Suitable for use in unshielded fixtures.
16
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Watts Bulb
Base
Product Symbols &
Number Footnotes
75
E26 Med Skt
14517
PAR38
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
75PAR38/HAL/WFL50
130 15
WFL
C,CC-8
2500
1060
2900
1300
50
5.31
43,72,118,137,181
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
90
PAR38
E26 Med Skt
14586
90PAR38/HAL/SP9
120 15
SP
C,CC-8
2500
1310
2925
19000
9
5.31
90PAR38/HAL/SP
120 6
SP
C,CC-8
2500
1310
2925
19000
9
5.31
90PAR38/HAL/SP9
130 15
SP
C,CC-8
2500
1310
2925
19000
9
5.31
43,72,118
15539
43,72,118
14587
43,72,118,137,187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14580
90PAR38/HAL/WSP12
120 15
WSP
C,CC-8
2500
1310
2925
14300
12
5.31
90PAR38/HAL/WSP12
130 15
WSP
C,CC-8
2500
1310
2925
14300
12
5.31
NFL
C,CC-8
2500
1310
2925
4700
25
5.31
43,72,118
14578
43,72,118,137,187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14601
90PAR38/HAL/NFL25
130 15
43,72,118,137,187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14579
90PAR38/HAL/FL30
120 15
FL
C,CC-8
2500
1310
2925
3500
30
5.31
90PAR38/HAL/FL
120 6
FL
C,CC-8
2500
1310
2925
3500
30
5.31
90PAR38/HAL/FL30
130 15
FL
C,CC-8
2500
1310
2925
3500
30
5.31
FL
C,CC-8
2500
1310
2925
3500
30
5.31
WFL
C,CC-8
2500
1310
2925
1600
50
5.31
43,72,118
15545
43,72,118
14577
43,72,118,137,187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14647
90PAR38/HAL/FL/CVP
130 6
43,72,118,137,187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14602
90PAR38/HAL/WFL50
130 15
43,72,118,137,187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
Med Side Prong 14630
90PAR38/HAL/3WSP12
120 15
WSP
C,CC-8
2500
1310
2925
14300
12
5.31
90PAR38/HAL/3FL30
120 15
FL
C,CC-8
2500
1310
2925
3500
30
5.31
100PAR38/HAL/SP9
120 6
SP
C,CC-8
2500
1500
2950
22000
9
5.31
100PAR38/HAL/FL30
120 6
FL
C,CC-8
2500
1500
2950
4000
30
5.31
106PAR38/HAL/SP10
120 15
SP
C,CC-8
2000
1800
2975
22500
10
5.31
106PAR38/HAL/WFL50
120 15
WFL
C,CC-8
2000
1800
2975
2000
50
5.31
120PAR38/HAL/SP10
120 15
SP
C,CC-8
3000
1800
2950
22500
10
5.31
120PAR38/HAL/SP
120 6
SP
C,CC-8
3000
1800
2950
22500
10
5.31
120PAR38/HAL/SP10
130 15
SP
C,CC-8
3000
1800
2950
22500
10
5.31
FL
C,CC-8
3000
1800
2950
4600
30
5.31
43,72,118
14632
43,72,118
100
PAR38
E26 Med Skt
15522
43,72,118
15585
43,72,118
106
PAR38
E26 Med Skt
15003
43,72,118
15001
43,72,118
120
PAR38
E26 Med Skt
14856
43,72,118
14873
43,72,118
14874
43,72,118,137,197
@ 120 volts, approximate 105 watts, 1370 lumens, 6000 hours
14855
120PAR38/HAL/FL30
43,72,118
For more complete product information visit www.sylvania.com
54
120 15
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
PAR38
9:56 AM
Page 55
PAR56
PAR64
CAPSYLITE® PAR38
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
120
E26 Med Skt
14576
PAR38
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
120PAR38/HAL/FL
120 6
FL
C,CC-8
3000
1800
2950
4600
30
5.31
120PAR38/HAL/FL30
130 15
FL
C,CC-8
3000
1800
2950
4600
30
5.31
43,72,118
14861
43,72,118,137,197
|
|
|
@ 120 volts, approximate 105 watts, 1370 lumens, 6000 hours
14594
120PAR38/HAL/WFL50
120 15
WFL
C,CC-8
3000
1800
2950
2000
50
5.31
250PAR38/HAL/SP10
120 6
SP
C,CC-8
4500
3600
3025
46500
10
5.31
250PAR38/HAL/FL30
120 6
FL
C,CC-8
4500
3600
3025
9000
30
5.31
43,72,118
250
PAR38
E26 Med Skt
15526
43,70,71,72,73,74
15558
43,70,71,72,73,74
CAPSYLITE® COOL LUX
Halogen PAR lamp with dichroic reflector. Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
90
E26 Med Skt
14972
PAR38
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
90PAR38/HAL/2SP12
120 15
SP
C,CC-8
2500
1260
2925
12000
12
5.31
90PAR38/HAL/2FL30
120 15
FL
C,CC-8
2500
1260
2925
3750
30
5.31
90PAR38/HAL/2FL30
130 15
FL
C,CC-8
2500
1260
2925
3750
30
5.31
72,89,118
14971
72,89,118
14973
72,89,118,137,187
|
|
|
LARGE PAR LAMPS
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility
of a lamp shattering and from possible ultraviolet radiation.
16
Product Symbols &
Number Footnotes
Watts Bulb
Base
500
Ext Mog End Pr 56210
PAR56
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
500PAR56Q/HAL/NSP
120 12
NSP
C,CC-6
4000
8800
2950
78500
8x15 5.00
500PAR56Q/HAL/MFL
120 12
MFL
C,CC-6
4000
8800
2950
40000
11x30 5.00
500PAR56Q/HAL/WFL
120 12
WFL
C,CC-6
4000
8800
2950
19500
20x45 5.00
1000PAR64Q/HAL/NSP
120 6
NSP
C,CC-6
4000
19400 135000 8x20 6.00
2950
1000PAR64Q/HAL/MFL
120 6
MFL
C,CC-6
4000
19400 82000
2950
10x30 6.00
1000PAR64Q/HAL/WFL
120 6
WFL
C,CC-6
4000
19400 23000
2950
20x60 6.00
57,139,188
56211
57,139,188
56212
57,139,188
1000
PAR64
Ext Mog End Pr 56206
57,139,188
56207
57,139,188
56208
57,139,188
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 64-68
55
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
T4
12/3/07
9:56 AM
T3, T4
Page 56
T4
CAPSYLITE® G9 LAMPS
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
25
G9 Bipin
57020
72,84,145
25T4/G9/CL
120
20
Clear
C,CC-2V
2000
255
2900
0.88
20x60
57034
72,84,145
25T4/G9/CL/BL
120
10
Clear
C,CC-2V
2000
255
2900
0.88
1.69
57021
72,84,145
25T4/G9/F
120
20
Frosted
C,CC-2V
2000
230
2900
0.88
1.69
57022
72,84,145
40T4/G9/CL
120
20
Clear
C,CC-2V
2000
510
2900
0.88
1.69
57033
72,84,145
40T4G9/CL/BL
120
10
Clear
C,CC-2V
2000
510
2900
0.88
1.69
57025
72,84,145
40T4/G9/F
120
20
Frosted
C,CC-2V
2000
480
2900
0.88
1.69
57017
72,84,145
40T4/G9/F/BL
120
10
Frosted
C,CC-2V
2000
480
2900
0.88
1.69
57023
72,84,145
60T4/G9/CL
120
20
Clear
C,CC-2V
2000
830
2900
1.06
2.00
57035
72,84,145
60T4G9/CL/BL
120
10
Clear
C,CC-2V
2000
830
2900
1.06
2.00
57024
72,84,145
60T4/G9/F
120
20
Frosted
C,CC-2V
2000
790
2900
1.06
2.00
40
60
T4
T4
T4
G9 Bipin
G9 Bipin
|
|
|
SUPERQ SINGLE END HALOGEN LAMPS
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility
of a lamp shattering and from possible ultraviolet radiation.
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
75
T3
Min Can
58884
123,139
75Q/CL/MC/RP
120
6
Clear
C,CC-8
2000
1400
2950
1.19
2.56
100
T4
DC Bayonet
58755
123,139
100Q/CL/DC(ESR)
120
12
Clear
C,CC-2V
1000
1900
2950
1.38
2.44
18845
123,139
100Q/CL/DC/64475
120
12
Clear
C,CC-2V
2000
1600
2950
2.19
3.38
58732
123,139
100Q/CL/DC
130
12
Clear
C,CC-2V
1000
1900
2950
1.38
2.44
58757
123,139
100Q/DC(ETD)
120
12
Frosted
C,CC-2V
1000
1750
2950
1.38
2.44
58761
123,139
100Q/CL/MC(ESN)
120
12
Clear
C,CC-2V
1000
1800
2950
1.38
2.75
58817
123,139
100Q/CL/MC/RP(ESN)
120
6
Clear
C,CC-8
1000
1800
2950
1.38
2.56
58760
123,139
100Q/CL/MC
130
12
Clear
C,CC-2V
1000
1800
2950
1.38
2.75
58741
123,139
150Q/CL/DC(ETC)
120
12
Clear
C,CC-8
2000
2800
2950
1.50
2.75
58742
123,139
150Q/CL/DC/1(ESP)
120
12
Clear
C,CC-2V
1000
2400
2950
1.38
2.44
58748
123,139
150Q/CL/DC
130
12
Clear
C,CC-2V
1000
2800
2950
1.38
2.75
58737
123,139
150Q/DC(ETF)
120
12
Frosted
C,CC-8
2000
2700
2950
1.50
2.75
Min Can
150
T4
DC Bayonet
For more complete product information visit www.sylvania.com
56
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
T4
9:56 AM
Page 57
T4
T3
SUPERQ SINGLE END HALOGEN LAMPS
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility
of a lamp shattering and from possible ultraviolet radiation.
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
150
Min Can
58738
123,139
150Q/CL/MC(ESL)
120
12
Clear
C,CC-2V
1000
2800
2950
1.38
2.75
58735
123,139
150Q/CL/MC/2(ETG)
120
12
Clear
C,CC-8
2000
2800
2950
1.50
3.00
58733
123,139
150Q/CL/MC
130
12
Clear
C,CC-2V
1000
2800
2950
1.38
2.75
58736
123,139
150Q/MC(ETH)
120
12
Frosted
C,CC-8
2000
2700
2950
1.50
3.00
58720
123,139
250Q/CL/DC(ESS)
120
12
Clear
C,CC-8
2000
5000
2950
1.63
3.13
58753
123,139
250Q/DC(ETB)
120
12
Frosted
C,CC-8
2000
4850
2950
1.63
3.13
58754
123,139
250Q/DC
130
12
Frosted
C,CC-8
2000
4850
2950
1.63
3.13
58762
123,139
250Q/CL/MC(EHT)
120
12
Clear
C,CC-8
2000
5000
2950
1.63
3.13
58764
123,139
250Q/CL/MC
130
12
Clear
C,CC-8
2000
5000
2950
1.63
3.13
58763
123,139
250Q/MC(ESM)
120
12
Frosted
C,CC-8
2000
4850
2950
1.63
3.13
58765
123,139
250Q/MC
130
12
Frosted
C,CC-8
2000
4850
2950
1.63
3.13
58766
123,139
500Q/CL/MC(EVR)
120
12
Clear
C,CC-8
2000
10450
2950
2.00
3.75
58756
123,139
500Q/CL/MC(EYW)
130
12
Clear
C,CC-8
2000
10000
2950
2.00
3.75
58767
123,139
500Q/MC(EYX)
120
12
Frosted
C,CC-8
2000
10100
2950
2.00
3.75
58768
123,139
500Q/MC(EYV)
130
12
Frosted
C,CC-8
2000
10000
2950
2.00
3.75
250
T4
T4
DC Bayonet
Min Can
500
T4
Min Can
|
|
|
DOUBLE END QUARTZ LAMPS
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility
of a lamp shattering and from possible ultraviolet radiation.
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
100
RSC
58999
123,139
100T3Q/S/CL
120
20
Clear
C,C-8
2000
1600
2950
3.13
58887
123,139
100T3Q/S/CL/RP
120
6
Clear
C,C-8
2000
1600
2950
3.13
59001
123,139
150T3Q/S/CL
120
20
Clear
C,C-8
2000
2400
2950
3.13
58886
123,139
150T3Q/S/CL/RP
120
6
Clear
C,C-8
2000
2400
2950
3.13
58885
123,139
150T3Q/CL/RP
120
6
Clear
C,C-8
1500
2250
2950
4.69
150
T3
T3
RSC
200
T3
RSC
59003
123,139
200T3Q/CL
120
20
Clear
C,C-8
2000
3350
2950
4.69
300
T3
RSC
58998
123,139
300T3Q/CL(EHM)
120
20
Clear
C,C-8
2000
6000
2950
4.69
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 64-68
57
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
12/3/07
T3
9:56 AM
Page 58
T3
BT4
BT4
DOUBLE END QUARTZ LAMPS
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility
of a lamp shattering and from possible ultraviolet radiation.
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
300
RSC
58920
123,139
300T3Q/CL/RP(EHM)
120
6
Clear
C,C-8
2000
6000
2950
4.69
59000
123,139
300T3Q/CL
130
20
Clear
C,C-8
2000
6000
2950
4.69
58996
123,139
500T3Q/CL(FCL)
120
20
Clear
C,C-8
2000
8750
2950
4.69
58865
123,139
500T3Q/CL/RP(FCL)
120
6
Clear
C,C-8
2000
8750
2950
4.69
58997
123,139
500T3Q/CL
130
20
Clear
C,C-8
2000
8750
2950
4.69
500
T3
T3
RSC
1000
T3
RSC
58948
123,139
1000T3Q/CL
240
12
Clear
C,C-8
2000
21500
2950
10.06
1500
T3
RSC
58859
123,139
1500T3Q/CL
208
12
Clear
C,C-8
2000
33000
2950
10.06
58857
123,139
1500T3Q/CL
240
12
Clear
C,C-8
2000
33000
2950
10.06
58858
123,139
1500T3Q/CL
277
12
Clear
C,C-8
2000
33000
2950
10.06
|
|
|
OSRAM MINISTAR LAMPS
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
10
G4 Bipin
58520
T3
72,84,123,
Ordering Abbreviation
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
10T3Q/MINISTAR/S
12
C,C-8
80
35 x 60 1.31
120
35 x 60 1.31
800
20
1.75
1000
30
1.75
40
FL
2000
3000
145
20
T3
G4 Bipin
58521
72,84,123,
20T3Q/MINISTAR/S
12
40
FL
C,C-8
2000
3000
145
BT4
GY6.35 Bipin
58518
72,84,123,
20BT4Q/MINISTAR/AX
12
40
FL
C,C-8
2000
3000
145
35
BT4
GY6.35 Bipin
58519
|
|
|
Pkg Beam
Volts Qty Type
72,84,123,
35BT4Q/MINISTAR/AX
12
40
FL
C,C-8
2000
3000
145
BI-PIN IR LAMPS
UV Filter capsule with axial filament and infrared reflective coating. Suitable for use in unshielded fixtures. Consult most recent
luminaire standards for your area to determine luminaire requirements.
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
25
BT4
GY6.35 Bipin
58897
145
25BT4Q/IR
12
40
Clear
C,AXIAL
4000
450
3000
1.13
1.75
35
BT4
GY6.35 Bipin
58896
145
35BT4Q/IR
12
40
Clear
C,AXIAL
4000
800
3000
1.13
1.75
For more complete product information visit www.sylvania.com
58
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 59
T3, T4
STARLITE BI-PIN LAMPS
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
10
G4 Bipin
58692
142,145
10T3Q/CL/AX
6
40
Clear
C,AXIAL
4000
130
3000
0.88
1.25
58691
142,145
10T3Q/CL/AX
12
40
Clear
C,AXIAL
4000
130
3000
0.88
1.25
20
T3
T3
G4 Bipin
58694
142,145
20T3Q/CL/AX
12
40
Clear
C,AXIAL
4000
320
3000
0.88
1.25
T4
GY6.35 Bipin
58663
142,145
20T4Q/CL/AX
12
40
Clear
C,AXIAL
4000
320
3000
1.13
1.75
35
T4
GY6.35 Bipin
58672
142,145
35T4Q/CL/AX
12
40
Clear
C,AXIAL
4000
600
3000
1.13
1.75
50
T4
GY6.35 Bipin
58676
142,145
50T4Q/CL/AX
12
40
Clear
C,AXIAL
4000
910
3000
1.13
1.75
75
T4
GY6.35 Bipin
58680
142,145
75T4Q/CL/AX
12
40
Clear
C,AXIAL
4000
1450
3000
1.13
1.75
90
T4
GY6.35 Bipin
58684
142,145
90T4Q/CL/AX
12
40
Clear
C,AXIAL
4000
1800
3000
1.13
1.75
|
|
|
STANDARD BI-PIN LAMPS
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
15
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
Watts Bulb
Base
Product Symbols &
Number Footnotes
5
G4 Bipin
58652
123,140,145
5T3Q/CL
12
40
Clear
C,TR
2000
60
3000
0.88
1.25
58651
123,141,145
5T3Q/F
12
40
Frosted
C,TR
2000
55
3000
0.88
1.25
58658
123,140,145
10T3Q/CL
12
40
Clear
C,TR
2000
140
3000
0.88
1.25
58650
123,140
10T3Q/CL/RP
12
6
Clear
C,TR
2000
140
3000
0.88
1.25
58656
123,141,145
10T3Q/F
12
40
Frosted
C,TR
2000
130
3000
0.88
1.25
58661
123,140,145
20T3Q/CL
12
40
Clear
C,TR
2000
320
3000
0.88
1.25
58655
123,140
20T3Q/CL/RP
12
6
Clear
C,TR
2000
320
3000
0.88
1.25
58675
123,140
50T4Q/CL
12
40
Clear
C,TR
2000
910
3000
1.13
1.75
58660
123,140
50T4Q/CL/RP
12
6
Clear
C,TR
2000
910
3000
1.13
1.75
Ordering Abbreviation
Pkg Lamp
Volts Qty Finish
Avg
Class & Rated Lumens LCL
Filament Life(hrs) CCT
(in)
MOL
(in)
10
20
50
T3
T3
T3
T4
G4 Bipin
G4 Bipin
GY6.35 Bipin
|
|
|
24V BI-PIN LAMPS
Suitable for use in unshielded fixtures.
15
Watts Bulb
Base
Product Symbols &
Number Footnotes
20
T3
G4 Bipin
58662
117,143
20T3Q/CL
24
40
Clear
C,AXIAL
1000
320
3000
0.88
1.25
50
T4
GY6.35 Bipin
58678
117,143
50T4Q/CL/AX
24
40
Clear
C,AXIAL
2000
850
3000
1.13
1.75
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 64-68
59
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 60
MR16
TRU-AIM IR® MR16 LAMPS
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector and infrared reflective coating on
the lamp capsule.
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
20
GU5.3 Bipin
58531
MR16
47,62,66,
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
20MR16/IR/SP10/C
12
C,AXIAL 5000
6000
10
1.75
2300
25
1.75
1000
35
1.75
450
60
1.75
12500
10
1.75
4400
25
1.75
2200
35
1.75
1100
60
1.75
15000
10
1.75
5700
25
1.75
2850
35
1.75
1430
60
1.75
20
SP
3000
91,93
58532
47,62,66,
20MR16/IR/NFL25/C
12
20
NFL
C,AXIAL 5000
3000
91,93
58533
47,62,66,
20MR16/IR/FL35/C
12
20
FL
C,AXIAL 5000
3000
91,93
58838
47,62,66,
20MR16/IR/WFL60/C
12
20
WFL
C, AXIAL 5000
3000
91,93
37
MR16
GU5.3 Bipin
58641
37,47,62,
37MR16/IR/SP10/C
12
20
SP
C, AXIAL 5000
3000
92,93
58634
37,47,62,
37MR16/IR/NFL25/C
12
20
NFL
C, AXIAL 5000
3000
92,93
58633
37,47,62,
37MR16/IR/FL35/C
12
20
FL
C, AXIAL 5000
3000
92,93
58837
47,62,66,
37MR16/IR/WFL60/C
12
20
WFL
C, AXIAL 5000
3000
92,93
50
MR16
GU5.3 Bipin
54175
37,47,62,
50MR16/IR/SP10/C
12
20
SP
C, AXIAL 5000
3000
92,93
54174
37,47,62,
50MR16/IR/NFL25/C
12
20
NFL
C, AXIAL 5000
3000
92,93
54173
37,47,62,
50MR16/IR/FL35/C
12
20
FL
C, AXIAL 5000
3000
92,93
54237
47,62,66,
|
|
|
50MR16/IR/WFL60/C
12
20
WFL
C, AXIAL 5000
3000
92,93
TRU-AIM TITAN® MR16 LAMPS
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
20
GU5.3 Bipin
58300
MR16
62,65,91,
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
20MR16/T/SP10/C(ESX)
12
C, AXIAL 4000
5000
10
1.75
780
35
1.75
350
60
1.75
9100
10
1.75
3100
25
1.75
1500
35
1.75
700
60
1.75
11500
10
1.75
4400
25
1.75
2200
35
1.75
20
SP
3000
145
58301
62,65,91,
20MR16/T/FL35/C(BAB)
12
20
FL
C, AXIAL 4000
3000
93,145
58302
62,65,91,
20MR16/T/WFL60/C
12
20
WFL
C, AXIAL 4000
3000
93,145
35
MR16
GU5.3 Bipin
58303
62,65,91,
35MR16/T/SP10/C(FRB)
12
20
SP
C, AXIAL 4000
3000
93,145
58304
62,65,91,
35MR16/T/NFL25/C
12
20
NFL
C, AXIAL 4000
3000
93,145
58305
62,65,91,
35MR16/T/FL35/C(FMW)
12
20
FL
C, AXIAL 4000
3000
93,145
58306
62,65,91,
35MR16/T/WFL60/C
12
20
WFL
C, AXIAL 4000
3000
93,145
50
MR16
GU5.3 Bipin
58307
62,65,91,
50MR16/T/SP10/C(EXT)
12
20
SP
C, AXIAL 4000
3000
93,145
58308
62,65,91,
50MR16/T/NFL25/C(EXZ)
12
20
NFL
C, AXIAL 4000
3000
93,145
58309
62,65,91,
93,145
For more complete product information visit www.sylvania.com
60
50MR16/T/FL35/C(EXN)
12
20
FL
C, AXIAL 4000
3000
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 61
MR16
TRU-AIM TITAN® MR16 LAMPS
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
GU5.3 Bipin
58310
MR16
62,65,91,
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50MR16/T/WFL60/C(FNV)
12
C, AXIAL 4000
1100
60
1.75
2650
25
1.75
13300
10
1.75
3800
25
1.75
2000
35
1.75
20
WFL
3000
93,145
58500
62,65,91,
50MR16/T/DAY/NFL25/C
12
10
NFL
C, AXIAL 4000
3050
93,145
65
MR16
GU5.3 Bipin
58311
62,65,92,
65MR16/T/SP10/C(FPA)
12
20
SP
C, AXIAL 4000
3000
93
58312
62,65,92,
65MR16/T/NFL25/C(FPC)
12
20
NFL
C, AXIAL 4000
3000
93
58313
|
|
|
62,65,92,
65MR16/T/FL35/C(FPB)
12
20
FL
C, AXIAL 4000
3000
93
TRU-AIM BRILLIANT® MR16 LAMPS
UV Filter capsule with axial filament in constant color, aluminized reflector.
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility
of a lamp shattering.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
20
GU5.3 Bipin
58314
MR16
33,62,91,
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
20MR16/B/SP10
12
C, AXIAL 4000
5000
10
1.75
780
35
1.75
9100
10
1.75
1500
35
1.75
12500
10
1.75
4400
25
1.75
2200
35
1.75
20
SP
3000
117
58315
33,62,91,
20MR16/B/FL35
12
20
FL
C, AXIAL 4000
3000
117
35
MR16
GU5.3 Bipin
58316
33,62,92,
35MR16/B/SP10
12
20
SP
C, AXIAL 4000
3000
117
58317
33,62,92,
35MR16/B/FL35
12
20
FL
C, AXIAL 4000
3000
117
50
MR16
GU5.3 Bipin
58319
33,62,92,
50MR16/B/SP10
12
20
SP
C, AXIAL 4000
3000
117
58320
33,62,92,
50MR16/B/NFL25
12
20
NFL
C, AXIAL 4000
3000
117
58321
|
|
|
33,62,92,
50MR16/B/FL35
12
20
FL
C, AXIAL 4000
3000
117
TRU-AIM® MR16 LAMPS
UV Filter capsule with axial filament in covered dichroic reflector.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
20
GU5.3 Bipin
54305
MR16
45,62,91,
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
20MR16/SP10/C(ESX)
12
C, AXIAL 2000
3000
10
1.75
510
35
1.75
6000
10
1.75
2000
25
1.75
1000
35
1.75
7800
10
1.75
20
SP
3000
93,145
54306
45,62,91,
20MR16/FL35/C(BAB)
12
20
FL
C, AXIAL 2000
3000
93,145
35
MR16
GU5.3 Bipin
54307
45,62,92,
35MR16/SP10/C(FRB)
12
20
SP
C, AXIAL 2000
3000
93,145
58322
45,62,92,
35MR16/NFL25/C
12
20
NFL
C, AXIAL 2000
3000
93,145
58324
45,62,92,
35MR16/FL35/C(FMW)
12
20
FL
C, AXIAL 2000
3000
93,145
50
MR16
GU5.3 Bipin
58325
45,62,92,
93,145
For more complete product information visit www.sylvania.com
|
|
|
50MR16/SP10/C(EXT)
12
20
SP
C, AXIAL 2000
3000
Symbols/Footnotes on page 64-68
61
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
12/3/07
9:56 AM
MR16, MR11, MR16 SIG 64005
Page 62
PAR36
TRU-AIM® MR16 LAMPS
UV Filter capsule with axial filament in covered dichroic reflector.
16
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Watts Bulb
Base
Product Symbols &
Number Footnotes
50
GU5.3 Bipin
58326
MR16
45,62,92,
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
50MR16/NFL25/C(EXZ)
12
C, AXIAL 2000
2800
25
1.75
1450
35
1.75
690
60
1.75
20
NFL
3000
93,145
58327
45,62,92,
50MR16/FL35/C(EXN)
12
20
FL
C, AXIAL 2000
3000
93,145
58328
|
|
|
45,62,92,
50MR16/WFL60/C(FNV)
12
20
WFL
C, AXIAL 2000
3000
93,145
TRU-AIM® MR11 LAMPS
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
20
GU4 Bipin
55133
MR11
62,65,92,
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
20MR11/T/SP10/C(FTB)
12
C, AXIAL 4000
4000
10
1.50
700
35
1.50
6200
10
1.50
1350
35
1.50
10
SP
3000
93
55134
62,65,92,
20MR11/T/FL35/C(FTD)
12
10
FL
C, AXIAL 4000
3000
93
35
MR11
GU4 Bipin
55135
62,65,92,
35MR11/T/SP10/C(FTE)
12
10
SP
C, AXIAL 4000
3000
93
55136
|
|
|
62,65,92,
35MR11/T/FL35/C(FTH)
12
10
FL
C, AXIAL 4000
3000
93
SIRIUS MR16 LAMPS
For traffic signal and other fiber optic applications.
16
Watts Bulb
50
Base
MR16
K23D
SIG 64005
Product Symbols &
Number Footnotes
58701
32,117
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
50SIRIUS/SIG64005
10
C, AXIAL 6000
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
10
Beam MOL
Angle (in)
220
3000
|
|
|
1.88
CAPSYLITE® PAR36 LAMPS
Suitable for use in unshielded fixtures.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
36
Screw Term
55100
73
36PAR36/HAL/VNSP5
12
12
VNSP
C, C-8
4000
500
3000
17000
5
2.75
55090
73
36PAR36/HAL/NSP13
12
12
NSP
C, C-8
4000
500
3000
3500
13
2.75
55091
73
36PAR36/HAL/WFL32
12
12
WFL
C, C-8
4000
500
3000
1000
30
2.75
55118
73
50PAR36/HAL/NSP6
12
12
NSP
C, C-8
4000
700
3000
25000
6
2.75
55017
73
50PAR36/HAL/WFL30
12
12
WFL
C, C-8
4000
700
3000
1400
30
2.75
50
PAR36
PAR36
Screw Term
For more complete product information visit www.sylvania.com
62
Symbols/Footnotes on page 64-68
|
|
|
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 63
AR70, AR111
AR70 ALUMINUM REFLECTOR LAMPS
UV Filter capsule with axial filament in precisely engineered aluminum reflector.
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
16
Watts Bulb
Base
Product Symbols &
Number Footnotes
20
DC Bayonet
59013
AR70
38,145
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
20AR70/SP8
12
C, C-8
7700
8
1.94
900
25
1.94
12500
8
1.94
2600
25
1.94
10
SP
3000
|
|
|
3000
59012
38,145
20AR70/FL25
12
10
FL
C, C-8
3000
3000
50
AR70
DC Bayonet
59017
38,145
50AR70/SP8
12
10
SP
C, C-8
3000
3000
59016
38,145
50AR70/FL25
12
10
FL
C, C-8
3000
3000
AR111 ALUMINUM REFLECTOR LAMPS
UV Filter capsule with axial filament in precisely engineered aluminum reflector.
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
16
Product Symbols &
Number Footnotes
Watts Bulb
Base
35
Push Screw Term 55101
AR111
38,145
Ordering Abbreviation
Pkg Beam
Volts Qty Type
Avg
Class & Rated Lumens
Filament Life(hrs) CCT
CBCP
Beam MOL
Angle (in)
35AR111/SSP4
6
C, C-8
30000
4
2.38
40000
4
2.38
14000
8
2.25
2500
25
2.31
45000
4
2.38
20000
8
2.25
4000
25
2.31
30000
8
2.25
5300
25
2.31
2000
45
2.19
48000
8
2.25
8500
25
2.31
2800
45
2.19
6
SSP
3000
|
|
|
3000
55102
38,145
35AR111/SSP4
12
6
SSP
C, C-8
3000
3000
55110
38,145
35AR111/SP8
12
6
SP
C, C-8
3000
3000
55114
38,145
35AR111/FL25
12
6
FL
C, C-8
3000
3000
50
AR111
Push Screw Term 55105
38,145
50AR111/SSP4
12
6
SSP
C, C-8
3000
3000
55104
38,145
50AR111/SP8
12
6
SP
C, C-8
3000
3000
55103
38,145
50AR111/FL25
12
6
FL
C, C-8
3000
3000
75
AR111
Push Screw Term 55125
38,145
75AR111/SP8
12
6
SP
C, C-8
3000
3000
55123
38,145
75AR111/FL25
12
6
FL
C, C-8
3000
3000
55124
38,145
75AR111/WFL45
12
6
WFL
C, C-8
3000
3000
100
AR111
Push Screw Term 55129
38,145
100AR111/SP8
12
6
SP
C, C-8
3000
3000
55127
38,145
100AR111/FL25
12
6
FL
C, C-8
3000
3000
55128
38,145
100AR111/WFL45
12
6
WFL
C, C-8
3000
3000
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 64-68
63
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 64
SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS
Symbol
Description
New item introduced within the past year.
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Item will be discontinued when inventory is depleted.
Indicates aluminum base.
Do not operate in household sockets.
Operate base down.
Operate base down to horizontal.
Heat resistant, hard glass.
PAR lamps are suitable for indoor and outdoor use.
Do not operate in paper lined sockets.
This lamp or ballast meets minimum Federal efficiency standards.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
Footnote
Description
1
Indefinite long life. Designed for life in excess of 10,000 hours. In -service life depends upon burning conditions.
2
Should not be used in equipment where base temperature will exceed 500 F.
3
@ 120 volts, approximate 119 watts, 1560 lumens, 6250 hours
4
@ 120 volts, approximate 119 watts, 1870 lumens, 1875 hours
5
@ 120 volts, approximate 132 watts, 1420 lumens, 6250 hours
6
@ 120 volts, approximate 132 watts, 1580 lumens, 2500 hours
7
@ 120 volts, approximate 132 watts, 1590 lumens, 2500 hours
8
@ 120 volts, approximate 132 watts, 1660 lumens, 1875 hours
9
@ 120 volts, approximate 132 watts, 1770 lumens, 1875 hours
10
@ 120 volts, approximate 132 watts, 1690 lumens, 6250 hours
11
@ 120 volts, approximate 132 watts, 1880 lumens, 1875 hours
12
@ 120 volts, approximate 132 watts, 2030 lumens, 1875 hours
13
High temperature base. Designed to operate in equipment where base te mperature run between 500F - 570F.
14
@ 120 volts, approximate 176 watts, 2190 lumens, 6250 hours
15
@ 120 volts, approximate 176 watts, 2220 lumens, 2500 hours
16
@ 120 volts, approximate 176 watts, 2350 lumens, 2500 hours
17
@ 120 volts, approximate 176 watts, 2360 lumens, 6250 hours
18
@ 120 volts, approximate 176 watts, 2710 lumens, 1875 hours
19
@ 120 volts, approximate 176 watts, 2740 lumens, 1875 hours
20
@ 120 volts, approximate 176 watts, 2820 lumens, 1875 hours
21
@ 120 volts, approximate 176 watts, 2860 lumens, 1875 hours
22
@ 120 volts, approximate 176 watts, 2220 lumens, 6750 hours
23
@ 120 volts, approximate 188 watts, 3190 lumens, 1125 hours
24
Designed for service other than illumination.
25
@ 120 volts, approximate 220 watts, 2360 lumens, 10000 hours
26
@ 120 volts, approximate 264 watts, 2310 lumens, 5000 hours
27
@ 120 volts, approximate 264 watts, 3800 lumens, 6250 hours
For more complete product information visit www.sylvania.com
64
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 65
SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS
Footnote
Description
28
@ 120 volts, approximate 264 watts, 3850 lumens, 6250 hours
29
@ 120 volts, approximate 264 watts, 4390 lumens, 1875 hours
30
@ 120 volts, approximate 264 watts, 4305 lumens, 1875 hours
31
Additional product information can be found in the SYLVANIA Automotive, Miniature and Sealed Beam Lamp Catalog Form 208.
32
UV Filter capsule with axial filament in dichroic reflector.
33
UV Filter capsule with axial filament in aluminized reflector.
34
UV Filter capsule with axial filament in covered aluminized reflector .
35
2 3/4" circular window.
36
UV Filter capsule with axial filament in constant color, hard coated dichroic reflector.
37
UV Filter capsule with axial filament in constant color, hard coated Dichroic reflector and infrared reflective coating on the lamp capsule.
38
UV Filter capsule with axial filament in precisely engineered aluminum m reflector.
39
Suitable for indoor and outdoor use;
40
For indoor use only; suitable for outdoor use only if not directly exposed to weather
41
For indoor use only;
42
UV control capsule with transverse constant color filament in hard dichroic
43
State of the Art SPL Optics
44
Inner capsule with Infrared conserving coating and hard glass lens
45
UV Filter capsule with axial filament in covered dichroic reflector.
46
Operate only in porcelain sockets.
47
Infrared lamp technology
48
Caution: Operates under pressure and may shutter. Use appropriate techniques to protect people and surroundings. Do not operate in close
proximity to persons, combustible materials, or substances affected by heat or drying. Do not operate over 110% rated voltage because such
operation increases pressure and lamps' tendency to shatter. Ultraviolet output may cause skin and eye irritation with prolonged exposure.
Protect bulb from abrasions and scratches. Do not insert lamps when power is on. Follow operation
49
ECE Approved
50
Lamp Life B3 @ 13.2 volts.
51
Universal lamp housings for T2 slide based pilot lamps.
52
Socket dimensions front to panel to end of terminals.
53
UL File No. E31557(M) CSA File No.LR20904
54
Universal lamp housings for T2.5 and T3.25 miniature bayonet based lamps.
55
UL File No. E31557(M) CSA File No.LR20904
56
MIL-Std. 18236 B-MIL Std. 202B
57
Should be shielded against moisture falling on bulb.
58
Material : Black Phenolic
59
There are two distinctively different lamps with this part number. When ordering T-1 3/4 , #7327, please also specify category and base type.
S-11. #7327 discontinued.
60
MOL = Excluding pins.
61
Material : Plastic
62
Max. seal temperature 350 C (662F)
63
Max. bulb temperature 1000 C (1832F)
64
Min. bulb temperature 250 C (482F)
65
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector.
66
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector and infrared reflective coating on the lamp capsule.
67
UV Filter capsule with transverse filament in constant color, hard co ated dichroic reflector .
68
Not recommended for use in enclosed close-fitting housings.
69
For Indoor Use only.
70
Because this bulb radiates considerable heat, do not use in enclosed, close fitting fixtures, or in close proximity to people, combustible materials, or substances adversely affected by heat or drying.
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
For more complete product information visit www.sylvania.com
65
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 66
SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Footnote
Description
71
Even though this bulb may continue to light after the lens or reflector is cracked or broken, it should be replaced as soon as possible since
the pressure filled inner capsule could unexpectedly shatter, creating a risk of personal injury or property damage. In addition, the inner capsule produces ultraviolet radiation that can cause injury to the eyes and skin with prolonged exposure without the blocking effect of the outer
glass bulb.
72
To avoid electric shock and/or skin burns, turn off power and allow bulb to cool before handling or attempting replacement.
73
For indoor or outdoor use where not directly exposed to weather. Exposure to weather may damage the bulb.
74
Use only with ceramic/porcelain sockets and in fixtures rated for this bulb type, including voltage and wattage.
75
Screw bulb firmly but not forcibly into socket to obtain good electrical contact and to avoid damaging bulb and/or socket. Socket condition
may affect bulb life. Replace socket if deterioration of socket or bulb contacts is observed.
76
Due to change from high pressure capsule to low pressure capsule, dimensions have been changed: LCL from 19.5 to 22mm and bulb diameter from 9 to 9.5mm.
77
@ 120 volts, approximate 26 watts, 150 lumens, 5000 hours.
78
Recommended operating position any within 60 degrees of vertically base up or base down.
79
@ 120 volts, approximate 28 watts, 200 lumens, 7500 hours.
80
@ 120 volts, approximate 53 watts, 340 lumens, 12500 hours.
81
@ 120 volts, approximate 66 watts, 500 lumens, 12500 hours.
82
@ 120 volts, approximate 88 watts, 765 lumens, 12500 hours.
83
@ 120 volts, approximate 88 watts, 1020 lumens, 2500 hours.
84
UV Filter Quartz
85
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
86
Operate only in heat resistant sockets
87
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
88
@ 120 volts, approximate 44 watts, 850 lumens, 6000 hours.
89
For use only in fixtures designed specifically for dichroic Reflector Lamps.
90
@ 120 volts, approximate 53 watts, 660 lumens, 6000 hours.
91
Max pin temperature 220 C.
92
Max pin temperature 250 C.
93
Max temperature at lens reflector joint 240 C.
94
Not for use in ceiling fan fixtures
95
For use where seal temperature does not exceed 662F.
96
Per Title 20 Section 1605.3(m) of the California Code of Regulations, this lamp may not be sold or offered for sale in the state of California
for use in Traffic Signals.
97
Board Size MFX Base 1.6mm (0.062") Inside of Board
98
OSRAM Miniwatt lamps for printed circuit boards (the MF series) are designed to work on both inside and outside contact boards and various thickness boards. In order to assure proper electrical contact, be sure to check the thickness of the board and the location of the electrical contacts.
99
@ 120 volts, approximate 33 watts, 270 lumens, 3750 hours.
100
Operate within 25 degrees of vertical base up.
101
@ 120 volts, approximate 53 watts, 490 lumens, 2500 hours.
102
@ 120 volts, approximate 66 watts, 650 lumens, 1875 hours.
103
@ 120 volts, approximate 88 watts, 970 lumens, 1875 hours.
104
@ 120 volts, approximate 46 watts, 560 lumens, 2500 hours.
105
@ 120 volts, approximate 40 watts, 220 lumens, 5000 hours.
106
@ 120 volts, approximate 57 watts, 410 lumens, 5000 hours.
107
Lamps manufactured on or after January 1, 2007 are not for sale in Washington or Oregon.
108
Per Title 20 Section 1605.3(k) of the California Code of Regulations, this lamp may not be sold or offered for sale in the state of California.
109
Lamp may not be operated on a dimmer or DC current
110
Complies with part 15 of FCC rules.
111
Average laboratory life is 200 hours for vacuum cleaner and 600 hours for sewing machine services.
112
Life dependent on service conditions.
113
Operating position 45 degrees base down to horizontal.
For more complete product information visit www.sylvania.com
66
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 67
SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS
Footnote
Description
114
Use only in fixtures designed to adequately dissipate heat from lamp.
115
3" Circular window.
116
Operation of lamp in any position other than base up may result in some loss of protective coating.
117
A protective shield must be used external to the lamp.
118
In base up operation, heat may eventually deteriorate paper-lined or plastic sockets.
119
Operate only in porcelain or other socket approved for 150 watt PAR lamp.
120
Metal sleeve with approximately 6 " flexible non-insulated leads. Lea ds not included in maximum overall length (M.O.L.).
121
High temperature base. Retards seal deterioration where seal temperature exceeds 650F.
122
Lightly inside frosted and side aluminized; M.O.L. exclusive of spring contact.
123
For use where seal temperature does not exceed 650F.
124
Life at rated voltage and at 650F maximum seal temperature.
125
Usually limited to intermittent burning.
126
Maximum bulb wall temperature 480F.
127
Lamp internally fused.
128
2 1/2" braided lead with lug.
129
Nickel sleeve with 11/4" - 11/2" flexible leads with lug. Leads not included in maximum overall length (M.O.L.)
130
Minimum run. Check nearest OSRAM SYLVANIA Sales Office for details.
131
This lamp should not be used in a location where water may be splashed on it.
132
Package quantity may change. See your OSRAM SYLVANIA Lighting Representative for details.
133
For diesel electric locomotives without voltage regulators.
134
Retrofit for 65BR30/FL, or 75R30/FL.
135
Available in bulk pack.
136
Incandescent lamps operated at less than rated voltage provide a lower light output, longer life, lower color temperature and are less efficient
in terms of lumens per watt.
137
Approximate life for 130 volt tungsten halogen lamps operated at 120 v olts is within the value calculated using the recommended equations
for standard incandescent lamps, as set forth in the IES Handbook, 8th edition. Because of the uncertain nature of the halogen cycle on the
coil when operated at less than rated voltage, life of tungsten halogen lamps varies considerably and unpredictably. OSRAM SYLVANIA does
not recommend operation at other than rated voltage.
138
Nominal wattage - actual may be slightly higher to achieve required light output.
139
A suitable protective shield, screening technique, or both must be used to protect people and surroundings from the possibility of a lamp
shattering and from possible ultraviolet radiation.
140
Standard Clear - UV Filter Quartz
141
Standard Frosted - UV Filter Quartz
142
Starlite Low Pressure - UV Filter Quartz
143
Standard Clear - 24V - UV Filter Quartz - Not suitable for use in open fixtures.
144
Maximum contact to contact tolerance on RSC Base = 1/16"
145
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
146
@120 volts, approximate 22 watts, 130 lumens, 6250 hours
147
@ 120 volts, approximate 26 watts, 100 lumens, 5000 hours
148
@ 120 volts, approximate 28/66/94 watts, 255/800/1060 lumens, 1800 hou rs
149
@ 120 volts, approximate 30 watts, 240 lumens, 6250 hours
150
@ 120 volts, approximate 30 watts, 290 lumens, 3750 hours
151
@ 120 volts, approximate 31 watts, 275 lumens, 5000 hours
152
@ 120 volts, approximate 35 watts, 320 lumens, 6250 hours
153
@ 120 volts, approximate 35 watts, 350 lumens, 3750 hours
154
@ 120 volts, approximate 37 watts, 450 lumens, 7000 hours
155
May not give satisfactory performance if any accessory lighting equipm ent touches the glass bulb.
156
@ 120 volts, approximate 38 watts, 380 lumens, 2250 hours
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
For more complete product information visit www.sylvania.com
67
020_TH_F_print.qxd
12/3/07
9:56 AM
Page 68
SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
Footnote
Description
157
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
158
@ 120 volts, approximate 44 watts, 250 lumens, 5000 hours
159
@ 120 volts, approximate 44 watts, 240 lumens, 5000 hours
160
@ 120 volts, approximate 44 watts, 400 lumens, 2500 hours
161
@ 120 volts, approximate 44 watts, 420 lumens, 5000 hours
162
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
163
@ 120 volts, approximate 46 watts, 460 lumens, 6250 hours
164
@ 120 volts, approximate 46 watts, 540 lumens, 2500 hours
165
@ 120 volts, approximate 46 watts, 600 lumens, 7000 hours
166
When calculations are based on bare lamp lumens, do not use this lumen rating.
167
@ 120 volts, approximate 47/94/141 watts, 545/1275/1820 lumens, 1800 hours
168
@ 120 volts, approximate 53 watts, 420 lumens, 2500 hours
169
@ 120 volts, approximate 53 watts, 495 lumens, 4000 hours
170
@ 120 volts, approximate 53 watts, 650 lumens, 2500 hours
171
@ 120 volts, approximate 53 watts, 645 lumens, 6000 hours
172
@ 120 volts, approximate 56 watts, 725 lumens, 1500 hours
173
@ 120 volts, approximate 57 watts, 540 lumens, 4375 hours
174
@ 120 volts, approximate 59 watts, 660 lumens, 6250 hours
175
@ 120 volts, approximate 59 watts, 780 lumens, 1875 hours
176
@ 120 volts, approximate 63 watts, 900 lumens, 7000 hours
177
Average laboratory life in excess of 5000 hours.
178
@ 120 volts, approximate 66 watts, 425 lumens, 4125 hours
179
@ 120 volts, approximate 66 watts, 620 lumens, 2500 hours
180
@ 120 volts, approximate 66 watts, 685 lumens, 4000 hours
181
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
182
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
183
@ 120 volts, approximate 66 watts, 910 lumens, 1875 hours
184
@ 120 volts, approximate 66 watts, 520 lumens, 5000 hours
185
@ 120 volts, approximate 70 watts, 985 lumens, 1125 hours
186
@ 120 volts, approximate 79 watts, 940 lumens, 6250 hours
187
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
188
For use only with heat-resisting connector and with bulb supported by bulb rim or metal shell of base.
189
@ 120 volts, approximate 79 watts, 1130 lumens, 1875 hours
190
@ 120 volts, approximate 88 watts, 960 lumens, 2500 hours
191
@ 120 volts, approximate 88 watts, 1100 lumens, 6250 hours
192
@ 120 volts, approximate 88 watts, 1260 lumens, 1875 hours
193
@ 120 volts, approximate 88 watts, 1290 lumens, 1875 hours
194
@ 120 volts, approximate 88 watts, 710 lumens, 5000 hours
195
@ 120 volts, approximate 94 watts, 1455 lumens, 1125 hours
196
@ 120 volts, approximate 105 watts, 850 lumens, 5000 hours
197
@ 120 volts, approximate 105 watts, 1370 lumens, 6000 hours
198
@ 120 volts, approximate 106 watts, 1040 lumens, 5000 hours
For more complete product information visit www.sylvania.com
68
100_cref.qxd
12/3/07
10:21 AM
Page 69
Manufacturers’ Cross Reference
HALOGEN LAMPS
SYLVANIA
HALOGEN BT15
60BT15/HAL/CL/BL
60BT15/HAL/W/BL
75BT15/HAL/W/BL
100BT15/HAL/W/BL
150BT15/HAL/W/BL
CAPSYLITE MIDBREAK
52A/CAP
60A/HAL/DAY
60A/HAL/DAY/CL
75A/HAL/DAY
100A/HAL/DAY
CAPSYLITE PAR
60PAR16/CAP/NSP10
60PAR16/CAP/NFL30
75PAR16/CAP/NSP10
75PAR16/CAP/NFL30
50PAR20/HAL/SPL/NFL30
50PAR20/HAL/SPL/NSP10
50PAR30/CAP/SPL/NFL25
50PAR30/CAP/SPL/NSP9
50PAR30/HAL/SPL/FL40
50PAR30LN/CAP/SPL/NFL30
50PAR30LN/CAP/SPL/NSP9
50PAR30LN/CAP/SPL/WFL50
60PAR30/CAP/SPL/NSP9
60PAR30/CAP/SPL/NFL25
75PAR30/CAP/SPL/NSP9
75PAR30/CAP/SPL/NFL25
75PAR30/CAP/SPL/FL40
75PAR30LN/CAP/SPL/NSP9
75PAR30LN/CAP/SPL/NFL25
75PAR30LN/CAP/SPL/WFL50
36PAR36CAPNSP13
36PAR36CAPVNSP5
36PAR36CAPWFL
50PAR36CAPNSP6
45PAR/CAP/SPL/SP9
45PAR/CAP/SPL/WSP12
45PAR/CAP/SPL/FL30
60PAR/CAP/SPL/SP9
60PAR/CAP/SPL/WSP12
60PAR/CAP/SPL/NFL25
60PAR/CAP/SPL/FL30
75PAR/CAP/SPL/SP9
75PAR/CAP/SPL/FL30
90PAR/CAP/SPL/SP9
90PAR/CAP/SPL/WSP12
90PAR/CAP/SPL/FL30
90PAR/CAP/SPL/WFL50
120PAR/CAP/SPL/SP9
120PAR/CAP/SPL/FL30
250PARCAPSPLSP10
250PARCAPSPLFL30
500PAR56QMFL
500PAR56QNSP
500PAR56QWFL
1000PAR64QMFL
1000PAR64QNSP
1000PAR64QWFL
CAPSYLITE IR PAR
50PAR30/CAP/IR/NSP9 130V
50PAR30/CAP/IR/NFL25 130V
GE
PHILIPS
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
OSRAM
-----------
BC60BT15/HAL/CL
BC60BT15/HAL/W
BC75BT15/HAL/W
BC100BT15/HAL/W
BC150BT15/HAL/W
-----------
50A/HAL
60A/HAL
60A/HAL/CL
75A/HAL
90A/HAL
-----------
-----------
60PAR16/H/SP10
60PAR16/H/FL30
75PAR16/H/SP10
75PAR16/H/FL30
50PAR20/H/FL25
50PAR20/H/SP10
50PAR30/H/FL25
50PAR30/H/SP10
50PAR30/H/FL35
50PAR30L/H/FL40
50PAR30L/H/SP10
50PAR30L/H/WFL
60PAR30/H/NSP9
60PAR30/H/FL25
75PAR30/H/SP10
75PAR30/H/FL25
75PAR20/H/FL35
75PAR30L/H/SP10
75PAR30L/H/FL25
75PAR30L/H/WFL
35PAR36/H/SP8
35PAR36/H/SP5
35PAR36/H/FL30
50PAR36/H/SP5
45PAR/H/SP10
--45PAR/H/FL25
60PAR/H/SP10
--60PAR/H/FL25
--75PAR/H/SP9
75PAR/H/FL25
90PAR/H/SP10
--90PAR/H/FL25
90PAR/H/WFL
120PAR/H/SP9
120PAR/H/FL30
Q250PAR/SP10
Q250PAR/FL30
Q500PAR56MFL
Q500PAR56NSP
Q500PAR56WFL
Q1000PAR64MFL
Q1000PAR64NSP
Q1000PAR64WFL
60PAR16/HAL/NSP10
60PAR16/HAL/NFL27
----50PAR20/HAL/NFL30
50PAR20/HAL/NSP9
50PAR30/HAL/NFL30
50PAR30S/HAL/NSP10
50PAR30S/HAL/FL40
50PAR30L/HAL/NFL30
50PAR30L/HAL/NSP9
50PAR30L/HAL/WFL60
60PAR30S/HAL/NSP10
60PAR30S/HAL/NFL30
75PAR30S/HAL/SP10
75PAR30S/HAL/NFL30
75PAR30S/HAL/FL40
75PAR30L/HAL/NSP9
75PAR30L/HAL/NFL30
75PAR30L/HAL/FL40
----------45PAR38/HAL/SP12/LL
45PAR38/HAL/FL28/LL
60PAR38/HAL/NSP10/WLL
60PAR38/HAL/SP12/WLL
--60PAR38/HAL/FL28/WLL
75PAR38/HAL/SP10/WLL
75PAR38/H/FL28/WLL
--90PAR38/HAL/SP12/LL
90PAR38/HAL/FL28/LL
90PAR38/HAL/WFL60/WLL
--------500PAR56Q/MFL
500PAR56Q/NSP
500PAR56Q/WFL
1000PAR64Q/MFL
1000PAR64Q/NSP
1000PAR64Q/WFL
-------------------------------------------------------
45PAR30/HIR/SP9XL
45PAR30/HIR/FL25XL
-----
-----
-----------------------------------------
For more complete product information visit www.sylvania.com
69
100_cref.qxd
12/3/07
10:21 AM
Page 70
Manufacturers’ Cross Reference Guide (continued)
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
HALOGEN LAMPS
SYLVANIA
CAPSYLITE IR PAR (continued)
50PAR30/CAP/IR/FL40 130V
50PAR30/CAP/IR/NSP9
50PAR30/CAP/IR/NFL25
50PAR30/CAP/IR/FL40
50PAR/CAP/IR/SP10 130V
50PAR/CAP/IR/NFL25 130V
50PAR/CAP/IR/SP10
50PAR/CAP/IR/NFL25
55PAR38/CAP/IR/XP/SP9
55PAR38/CAP/IR/XP/FL30
60PAR/CAP/IR/SP10
60PAR/CAP/IR/WSP12
60PAR/CAP/IR/NFL25
60PAR/CAP/IR/FL30
80PAR/CAP/IR/SP10
80PAR/CAP/IR/FL25
100PAR/CAP/IR/SP10
100PAR/CAP/IR/NFL25
100PAR/CAP/IR/FL40
TRU-AIM MR11
20MR11/SP10/FTB
20MR11/FL35/FTD
35MR11/FL40/FTH
35MR11/SP10/FTE
STANDARD TRU-AIM MR16
20MR16/NSP8/ESX
20MR16/FL40/BAB
35MR16/FL40
50MR16/NSP12/EXT
50MR16/NFL25/EXZ
50MR16/FL40/EXN
65MR16/NSP10/FPA
65MR16/FL40/FPB
TRU-AIM BRILLIANT MR16
20MR16/B/FL35/C
50MR16/B/NSP11/C/EXT
50MR16/B/NFL25/EXZ
50MR16/B/FL35/C/EXN
TRU-AIM TITAN MR16
20MR16/T/NSP10/ESX
20MR16/T/FL40/BAB
35MR16/T/NSP10/FRB
35MR16/T/NFL25
35MR16/T/FL40/FMW
50MR16/T/NSP10/EXT
50MR16/T/NFL25/EXZ
50MR16/T/FL40/EXN
50MR16/T/VWFL60/FNV
65MR16/T/NSP10/FPA
65MR16/T/NFL25
65MR16/T/FL40/FPB
TRU-AIM IR MR16
20MR16/IR/SP10/C
20MR16/IR/NFL25/C
20MR16/IR/FL40/C
20MR16/IR/WFL60/C
37MR16/IR/SP10/C
37MR16/IR/NFL25/C
37MR16/IR/FL40/C
37MR16/IR/WFL60/C
50MR16/IR/SP10/C
50MR16/IR/NFL25/C
GE
OSRAM
45PAR30/HIR/FL35XL
50PAR30/HIR/SP9
50PAR30/HIR/FL25
50PAR30/HIR/FL35
45PAR/HIR/SP12/XL
45PAR/HIR/FL40/XL
50PAR/HIR/SP9
50PAR/HIR/FL25
55PAR/HIR/SP12/XL
55PAR/HIR/FL40/XL
60PAR/HIR/SP10
60PAR/HIR/SP12
--60PAR/HIR/FL30
80PAR/HIR/SP10
80PAR/HIR/FL25
100PAR/HIR/SP10
100PAR/HIR/FL25
100PAR/HIR/FL40
--50PAR30S/IRC/NSP10
50PAR30S/IRC/NFL30
50PAR30S/IRC/FL40
----50PAR38/IRC/SP12
50PAR38/IRC/FL25
----60PAR38/IRC/SP10
60PAR38/IRC/WSP12
60PAR38/IRC/FL25
------100PAR38/IRC/SP10
100PAR38/IRC/FL25
---
---------------------------------------
Q20MR11/SP15(FTC)
Q20MR11/NFL30(FTD)
Q35MR11/NFL30(FTH)
Q35MR11/SP20(FTF)
20MRC11/SP10
20MRC11/FL30
-----
46890SP
46890WFL
46892WFL
46892SP
Q20MR16/SP
Q20MR16/FL
Q35MR16CG/FL
Q50MR16/SP
--Q50MR16/FL
-----
20MRC16/SP10
20MRC16/FL36
--50MRC16/SP10
50MRC16/NFL24
50MRC16/FL38
75MR16/SP10-EYF
75MR16/FL36-EYC
41860SP
41860WFL
41865WFL
41870SP
--41870WFL
-----
---------
--50MRC16/SP12/A
50MRC16/NFL24/A
50MRC16/FL36
41861WFL
----41871WFL
Q20MR16/C/VNSP7
Q20MR16/C/FL40
--Q35MR16/C/SP20
Q35MR16/C/FL40
Q50MR16/C/NSP15
Q50MR16/C/NFL25
Q50MR16/C/FL40
Q50MR16/C/WFL55
Q71MR16/C/NSP15
Q71MR16/C/NFL25
Q71MR16/C/FL40
20MRC16/CC/SP10
20MRC16/CC/FL38
------50MRC16/CC/SP10
50MRC16/CC/NFL24
50MRC16/CC/FL38
---------
46860SP
46860WFL
46865SP
46865FL
46865WFL
46870SP
46870FL
46870WFL
46870VWFL
-------
--------Q37MR16/HIR/CG10
Q37MR16/HIR/CG25
Q37MR16/HIR/CG40
--Q50MR16/HIR/CG10
Q50MR16/HIR/CG25
20MRC16/IRC/SP8
--20MRC16/IRC/FL36
--35MRC16/IRC/SP8
35MRC16/IRC/NFL24
35MRC16/IRC/FL36
35MRC16/IRC/WFL60
45MRC16/IRC/SP8
45MRC16/IRC/NFL24
48860SP
48860FL
48860WFL
48860VWFL
48865SP
48865FL
48865WFL
48865VWFL
48870SP
48870FL
For more complete product information visit www.sylvania.com
70
PHILIPS
100_cref.qxd
12/3/07
10:21 AM
Page 71
Manufacturers’ Cross Reference (continued)
HALOGEN LAMPS
SYLVANIA
TRU-AIM IR MR16 (continued)
50MR16/IR/FL40/C
50MR16/IR/WFL60/C
SINGLE ENDED
100Q/CL/DC/64485
100Q/CL/DC/ESR
100Q/CL/MC/ESN
100Q/DC/ETD
150Q/CL/DC/1/ESP
150Q/CL/DC/ETC
150Q/CL/MC/2/ETG
150Q/CL/MC/ESL
150Q/DC/ETF
150Q/MC/ETH
250Q/CL/DC/ESS
250Q/CL/MC/EHT
250Q/DC/ETB
250Q/MC/ESM
DOUBLE ENDED
100T3Q/CL
150T3Q/S/CL
150T3Q/CL
300T3Q/CL
500T3Q/CL
BIPIN
5T3Q/CL
10T3Q/CL
20T3Q/CL
50T4Q/CL
75T4Q/CL/RP
10T3Q/CL/AX
20T3Q/CL/AX
35T4Q/CL/AX
50T4Q/CL/AX
75T4Q/CL/AX
90T4Q/CL/AX
AR 70 & AR111
20AR70/SP8
20AR70/FL25
50AR70/SP8
50AR70/FL25
35AR111/SSP4
50AR111SSP4
50AR111/SP8
50AR111/FL25
75AR111/SP8
75AR111/FL25
75AR111/WFL45
100AR111/SP8
100AR111/FL25
100AR111/WFL45
GE
PHILIPS
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
OSRAM
Q50MR16/HIR/CG40
---
45MRC16/IRC/FL36
45MRC16/IRC/WFL60
48870WFL
48870VWFL
--Q100CL/DC
Q100CL/MC
Q100DC
Q150CL/DC/2V
Q150CL/DC
Q150CL/MC
Q150CL/MC/2V
Q150DC
Q150MC
Q250CL/DC
Q250CL/MC
Q250DC
Q250MC
--100Q/CL/DC ESR
100Q/CL ESN
----150Q/CL/DC ETC
150Q/CL
--150Q/DC
150Q ETH
250Q/CL/DC ESS
250Q/CL EHT
-----
64485
---------------------------
Q100T3/CL/CD
Q150T4/CL
Q150T3/117/CL/CD
Q300T3/CL
Q500T3/CL
BC100T3Q/CL/TP
BC150T3Q/CL/TP
--300T3Q/P/CL
500T3Q/P/CL
-----------
Q5T3/CL
Q10T3/CL
Q20T3/CL/CD
Q50T3/CL
Q75T4/CL/CD
----Q35T3/CL
-------
5W/12V/CAPSULE
----50W/12V/CAPSULE
--10W/12V/CAPSULE
20W/12V/CAPSULE
35W/12V/CAPSULE
-------
64405S
64415
64425
64440
--64415S
64425S
64432S
64440S
64450S
64458S
-----------------------------
15ALR18/NSP6-GBA
--50ALR18/SP10-GBJ
50ALR18/NFL22-GBK
---------------------
41970 SP USA
41970 FL USA
41990 SP USA
41990 FL USA
41830 SSP
41835 NSP 12V 50W
41835 SP 12V 50W
41835 FL 12V 50W
41840 SP 12V 75W
41840 FL 12V 75W
41840 WFL 12V 75W
41850 SP 12V 100W
41850 FL 12V 100W
41850 WFL 12V 100W
For more complete product information visit www.sylvania.com
71
030_MIN_F_print.qxd
12/12/07
3:12 PM
Page 72
MINIATURE & AUTOMOTIVE LAMPS
17
M
I
N
I
A
T
U
R
E
Ordering Abbreviation
Product
Number
Bulb
Base
1076
1130
1141
1156
1156
1157
36183
36237
36377
36521
36521
36561
S8
S8
S8
S8
S8
S8
DC Bayonet
DC Bayonet
SC Bayonet
SC Bayonet
SC Bayonet
DC Index
120MB
120MB
120MB 6W
120PC
120PSB
120PSB
12PSB
161
168
17
1815
1816
1819
1820
1822
1829
1835
1847
1864
1893
1895
194
1992 ERD
214-2 BU
2187
222
2342 24:30V30MA
24E
24ESB
24MB
34503
34503
34513
34519
34557
34557
32983
34691
34711
33061
37329
37333
37351
37355
37367
37377
37387
37391
37413
37505
37531
34761
30215
34942
37747
34967
39307
33181
33189
33213
T2.5
T2.5
T2.5
T2
T2
T2
T2
T3.25
T3.25
T1.75
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
G4.5
T3.25
T3.25
T3
T1.75
TL3
T5
T2
T2
T2.5
Mini Bayonet
Mini Bayonet
Mini Bayonet
Bipin
Slide Base # 5
Slide Base # 5
Slide Base # 5
W2.1x9.2D
W2.1x9.2D
W2.1x4.9D
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
W2.1x9.2D
Wedge
End Caps
5/8" Wire Term
Mini Screw
W2x4.6D
Slide Base # 3
Slide Base # 5
Mini Bayonet
24PSB
24X
259
28ESB
28MB
28PSB
30099 PLH
30110 PILOT TPLR
30112 PILOT TPLG
30120 PILOT FLR
31099 PLH BAY
313
3157WL
33229
33257
35027
33285
33311
33327
32169
32161
32159
32119
32173
35133
59894
T2
T2
T3.25
T2
T2.5
T2
T2
T2
T2
T2
T2.5 & T3.25
T3.25
S8
Slide Base # 5
Slide Base # 3
W2.1x9.2D
Slide Base # 5
Mini Bayonet
Slide Base # 5
Socket
Dome Trans
Dome Trans
Dome Fluted
Socket
Mini Bayonet
Wedge
327
328
35155
35169
T1.75
T1.75
SC Midg Flanged
SC Midg Flanged
For more complete product information visit www.sylvania.com
72
Avg
Rated
Life (hrs)
200
200
1000
1200
1200
1200
5000
10000
10000
3000
7500
10000
10000
12000
4000
1500
5000
3000
1000
2500
1000
1000
1000
5000
5000
1500
2500
2000
2500
150
1000
7000
5
1000
7000
8000
10000
10000
8000
5000
6000
5000
5000
500
1200
5000
4000
1000
Approx
Lumens
402.12
263.89
263.89
402
402
402.00
38.00
4.52
4.52
18
12.57
37.7
8.17
17.59
37.7
4.27
20.11
26.39
12.57
13.82
4.78
37.7
25.13
25.13
25.13
804
50.27
3.7
6.28
8.17
3.64
43.92
402.12
37.69
4.27
4.27
Amps
Design
Pkg
Voltage (V) Qty
MOL
(in)
1.8
2.63
1.44
2.1
2.1
2.1
0.6
0.025
0.025
0.052
0.025
0.025
0.025
0.17
0.19
0.35
0.065
0.2
0.33
0.04
0.1
0.1
0.07
0.05
0.15
0.17
0.33
0.27
0.27
2.5
0.52
0.04
0.22
0.3
0.035
0.04
0.07
13
6
13
13
13
13
14
120
120
120
120
120
120
12
14
14
28
14
13
28
28
36
28
55
6
28
14
14
14
14
14
28
2
24
24
24
24
1000
1000
1000
1000
1000
1000
2
2
2
2
2
2
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
24
1000
1000
1000
200
1000
1000
1000
1.19
1.19
1.19
1.125 1
1.11
1.11
1.11
1.054
1.054
0.8
1.19
1.19
1.19
1.19
1.19
1.19
1.19
1.19
1.19
1.19
1.06
1.054
1
1.72
0.52
0.94
0.78
1.69
1.11
1.19
0.072
0.035
0.25
0.04
0.04
0.04
24
24
6
28
28
28
1000
1000
1000
1000
1000
1000
100
1000
1000
1000
100
1000
1000
1.11
1.69
1.054
1.11
1.19
1.11
0.91
0.38
0.38
0.38
1.68
1.06
1.7
1000
1000
0.63
0.63
0.17
2.1
0.59
0.04
0.2
28
13
14
28
6
Footnotes
||
|
2,3,4
5
5
5
2,4,6
Symbols/Footnotes on page 74
030_MIN_F_print.qxd
12/12/07
3:12 PM
Page 73
MINIATURE & AUTOMOTIVE LAMPS
Ordering Abbreviation
17
Product
Number
Bulb
Base
Avg
Rated
Life (hrs)
Approx
Lumens
Amps
Design
Pkg
Voltage (V) Qty
MOL
(in)
330
334
3797 24V2W
382
385
387
388
44
35183
35205
39375
35311
35321
35327
35349
33459
T1.75
T1.75
T2.75
T1.75
T1.75
T1.75
T1.75
T3.25
SC Midg Flanged
Midget Groove
BA9S
SC Midg Flanged
SC Midg Flanged
SC Midg Flanged
Midget Groove
Mini Bayonet
1500
4000
200
15000
10000
7000
7000
3000
6.28
4.27
16.96
3.76
1.88
3.76
3.76
11.28
0.08
0.04
0.083
0.08
0.04
0.04
0.04
0.25
14
28
24
14
28
28
28
6
1000
1000
200
1000
1000
1000
1000
1000
0.63
0.63
0.932
0.63
0.36
0.63
0.63
0.94
4414 PAR 36
464
47
48C
48PSB
502
516/2PK/RP 12V
52A TB OBS
53
55
56
57
60MB
60PSB
6411 12V10W
64111 12V5W
6413 12V5W
64150 H1 12V55W
64151 H3 12V55W
64156 H3 24V70W
6421 24V3W
6424 24V5W
6429 24V10W
656
657
657
67
68
6PSB
73
7327 BIPIN T1 3/4
7371
7382
7511 P21W 24V21W
755
755
756
757
85
86
88
89
90
90MB
30965
35413
33479
33507
33599
35417
35920
33711
33719
33785
33831
33871
33927
33945
39407
39431
39405
31393
31397
31415
39376
39411
39397
35561
35565
35565
34021
34067
32803
34091
38289
38379
38417
39361
35763
35763
35771
35781
34179
34201
34219
34233
34271
34299
PAR36
T3.25
T3.25
T2
T2
G4.5
T5
T2
G3.5
G4.5
T1.75
G4.5
T2.5
T2
T3.25
T2.75
T3.25
T2.5
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
T3.25
G6
G6
T2
T1.75
T1.75
T1.75
T1.75
S8
T3.25
T3.25
T3.25
T3.25
T1.75
T1.75
S8
G6
G6
T2.5
2 Screw Terminal
W2.1x9.2D
Mini Bayonet
Slide Base # 3
Slide Base # 5
Mini Screw
W2.1x9.2D
Slide Base # 6
Mini Bayonet
Mini Bayonet
W2.1x4.9D
Mini Bayonet
Mini Bayonet
Slide Base # 5
SV8.5-8
Mini Bayonet
SV8.5-8
P14.5S
PK22S
PK22S
SV8.5-8
SV8.5-8
SV8.5-8
W2.1x9.2D
W2.1x9.2D
W2.1x9.2D
SC Bayonet
DC Bayonet
Slide Base # 5
W2.1x4.9D
Bipin
Bipin
Bipin
BAY15S
Mini Bayonet
Mini Bayonet
Mini Bayonet
Mini Bayonet
W2.1x4.9D
W2.1x4.9D
DC Bayonet
SC Bayonet
DC Bayonet
Mini Bayonet
300
1500
3000
7000
10000
100
300
8000
1000
500
20000
500
7500
7500
200
240
200
225
225
225
1000
200
200
2500
15000
15000
5000
5000
20000
15000
4000
20000
15000
150
20000
20000
15000
7500
7000
20000
300
750
750
5000
1.41
0.17
0.15
0.035
0.05
0.15
0.312
0.03
0.12
0.41
0.115
0.24
0.05
0.05
0.83
13
28
6
48
48
5
13
24
14
7
5
14
60
60
12
12
12
12
12
24
24
24
24
28
28
28
14
14
6
14
28
12
14
24
6
6
14
28
28
6
7
13
13
90
12
1000
1000
1000
1000
1000
12
1000
1000
1000
1000
1000
1000
1000
200
200
200
100
100
100
200
200
200
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
200
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
2 3/4
1.054
0.94
1.69
1.69
1.06
1.49
0.92
0.6
0.84
0.8
0.84
1.19
1.11
1.61
1.29
1.61
2.43
1.65
1.65
1.61
1.61
1.61
1.054
1.054
1.054
1.44
1.44
1.11
0.8
0.63
0.63
0.63
2.095
0.94
0.94
1.06
1.06
0.8
0.8
2
1.44
1.44
1.19
For more complete product information visit www.sylvania.com
37.7
6.28
7.53
43.98
12.57
25.13
1.88
25.13
9.17
100.53
80.42
100.53
1621.06
1520.53
1834.69
17.59
61.95
105.55
7.79
7.79
7.79
50.27
50.27
3.77
4.27
1.25
3.76
464.95
4.15
4.15
3.9
7.79
3.77
5.03
188.5
75.4
75.4
4.67
0.4
0.125
0.2
0.42
0.06
0.08
0.08
0.69
0.59
0.14
0.08
0.04
0.04
0.08
0.88
0.15
0.15
0.08
0.08
0.04
0.2
1.91
0.58
0.58
0.03
Footnotes
||
|
M
I
N
I
A
T
U
R
E
7
8,9
8,9
10
Symbols/Footnotes on page 74
73
030_MIN_F_print.qxd
12/12/07
3:12 PM
Page 74
MINIATURE & AUTOMOTIVE LAMPS
17
M
I
N
I
A
T
U
R
E
Ordering Abbreviation
Product
Number
Bulb
Base
Avg
Rated
Life (hrs)
912
918
918/2PK/RP 13V
93
93BL2PK 13V
94
NE51 B1A
NE51H B2A
35869
35923
35921
34311
16810
34337
32427
32429
T5
T5
T5
S8
S8
S8
T3.25
T3.25
W2.1x9.2D
W2.1x9.2D
W2.1x9.2D
SC Bayonet
SC Bayonet
DC Bayonet
Mini Bayonet
Mini Bayonet
1000
500
500
700
700
700
25000
25000
150.8
81.62
81.68
188.5
188.49
187.87
PR12
PR13
PR2
PR3
PR4
PR6
SM2A PCS 30096
38931
38939
38891
38901
38911
38917
32249
B3.5
B3.5
B3.5
B3.5
B3.5
B3.5
T2
SC Mini Flanged
SC Mini Flanged
SC Mini Flanged
SC Mini Flanged
SC Mini Flanged
SC Mini Flanged
Solder Lugs
15
15
15
15
10
30
37.69
25.13
10.05
18.84
5.02
5.65
Approx
Lumens
Amps
Design
Pkg
Voltage (V) Qty
MOL
(in)
1
0.54
0.54
1.04
1.04
1.04
0.3
1.2
13
13
13
13
13
13
105
105
500
500
12
1000
24
1000
1000
1000
1.49
1.49
1.49
2
1.8
2
0.5
0.5
0.5
0.5
0.27
0.3
6
5
2
4
2
2
1000
1000
1000
1000
1000
1000
500
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1.2
Footnotes
||
|
11
11
2,12,13
FOOTNOTES FOR MINIATURE LAMPS
Footnote
Description
1
MOL = Excluding pins.
2
Socket dimensions front to panel to end of terminals.
3
UL File No. E31557(M) CSA File No.LR20904
4
Universal lamp housings for T2.5 and T3.25 miniature bayonet based lamps.
5
Universal lamp housings for T2 slide based pilot lamps.
6
UL File No. E31557(M) CSA File No.LR20904
7
Caution: Operates under pressure and may shutter. Use appropriate techniques to protect people and surroundings. Do not operate in close
proximity to persons, combustible materials, or substances affected by heat or drying. Do not operate over 110% rated voltage because
such operation increases pressure and lamps' tendency to shatter. Ultraviolet output may cause skin and eye irritation with prolonged exposure. Protect bulb from abrasions and scratches. Do not insert lamps when power is on. Follow operating instructions.
8
ECE Approved
9
Lamp Life B3 @ 13.2 volts.
10
There are two distinctively different lamps with this part number. When ordering T-1 3/4 , #7327, please also specify category and base type.
S-11. #7327 discontinued.
11
Material : Black Phenolic
12
MIL-Std. 18236 B-MIL Std. 202B
13
Material : Plastic
For more complete product information visit www.sylvania.com
74
040_HID_drop.qxd
12/12/07
3:14 PM
Page 75
OSRAM SYLVANIA: THE LEADER IN ENERGY-SAVING HID LAMPS
UNDERSTANDING HIGH INTENSITY DISCHARGE LIGHTING
A brief description of the catalog format and related terminology will assist the
reader in understanding the information presented in this section.
All product families are listed in ascending wattage, followed by alphabetical bulb
designation to simplify lamp identification. Performance ratings are based on
tests conducted under controlled conditions on AC circuits with auxiliary equipment meeting current published ANSI specifications.
Lamp performance under typical service conditions may vary from rated values.
Ratings and specifications are subject to change without notice.
For more information on HID SYSTEM SOLUTIONS, refer to page 101.
ANSI CODE
This is a unique code that describes the class and the electrical characteristics of
the lamp and ballast as well as the fixture requirements. The code is developed
and assigned by the American National Standards Institute (ANSI). It is intended
to aid in matching the lamp to both the correct ballast and to a luminaire with the
required features. The ANSI CODE consists of type of lamp (S = HPS, H =
Mercury, M = Metal Halide, L = LPS, C = Ceramic Metal Halide), followed by the
ballast number, and for metal halide and Ceramic metal halide lamps followed by
the fixture requirement (O, E, S, F).
The emergence of electronic ballasts to operate metal halide lamps has produced
additional need to separate the lamp designation of quartz and ceramic metal
halide lamps, as there can be some important differences in system performance.
Therefore the C lamp designation from NEMA has been introduced going forward
for future differentiation of ceramic metal halide lamps and they will begin to be
labeled accordingly.
ARC LENGTH
Arc length is the dimension of the arc discharge measured from one electrode tip
to the other. This is useful for optical design of reflectors and affects fixture
efficiency.
AVERAGE LIFE (HOURS)
The average life of a lamp is based on vertical operation (unless otherwise noted)
of representative lamps operated under controlled conditions of at least 10 hours
per start (except for M1500 and Briteline lamps, which are based on 5 hours per
start). Average life is defined as the total operation hours at which 50% (Median)
of any group of lamps is still operating (except for most High Pressures Sodium
and Mercury lamps, for which 65% of the lamps are operating at the end of life
denoted by a "+" next to the life rating). Variations in operating conditions such
as bulb and base temperatures and line voltage can also affect lamp life.
Regular operation of lamps with off times less than the hot restrike time will
shorten lamp life. For hot restrike values of specific lamp types, please refer to
the SYLVANIA Metal Halide Lamp Specification Guide.
Operating cycles shorter than 10 hours per start will reduce lamp life as follows:
5 hours / start - Approximately 75% of rating
Rx7s / R7s Recessed Single Contact - SYLVANIA double-ended HID lamps
with recessed single contact (RSC) bases have silver plated contacts to
provide maximum electrical contact.
BULB
Each bulb description consists of a letter to indicate bulb shape, followed by
numbers that indicate maximum bulb diameter in 1/8 inch increments. For
example, a BT37 bulb is a blown shape with a tubular top, 37/8 of an inch or 4 5/8
inches in diameter. Illustrations of bulb shapes are shown on the following pages.
Although SYLVANIA HID bulbs are made of glass designed to resist thermal
shock in normal applications, they must be shielded from direct contact with
liquids, such as rain, during operation to avoid bulb breakage.
H
I
D
COLOR RENDERING INDEX (CRI)
Color Rendering Index (CRI) is an international scale (numbering system) up to
100 indicating the relative color rendering quality of a light source when
compared to a standard reference light source of the same chromaticity (color
temperature). The CRI expresses the degree to which colors will appear "familiar"
or "natural" under the light source selected. In general, the higher the CRI
number, the better the color rendering properties of the light source being
measured. The color rendering index of any two like sources should only be
compared if those sources have the same correlated color temperature (CCT).
CORRELATED COLOR TEMPERATURE (CCT)
The correlated color temperature of a light source, expressed in Kelvin (K), is a
means of describing the appearance or chromaticity of the source. The correlated
color temperature of the light source contributes to the visual appearance of the
lighted space. "Warm" light sources have a low color temperature (2000-3000K)
and feature more light in the red/orange/yellow range. Light with a higher color
temperature (>4000K) features more blue and is referred to as "cool."
With new installations, or group relamps, all color performance evaluations
should be made after at least 100 hours of operation (at recommended operating
cycles) to allow the lamps to stabilize. Additional changes in chemistry within the
arc tube over the life of the lamp may also cause the color temperature to shift as
the lamp gets closer to the end of it's rated life. To minimize color variation
within an installation, it is recommended that HID lamps be group relamped and
run on equal operating cycles.
DIMMING HID
Most SYLVANIA HID products can be dimmed on stepped, bi-level dimming
systems provided specific guidelines are followed. Generally, most Metalarc®
metal halide lamps can be dimmed down to 50% of rated wattage depending on
the lamp type and operating position. Lumalux® high pressure sodium lamps can
also be dimmed down to 50% of rated wattage. In addition to lower light output,
HID lamps may shift in overall color and exhibit a lower color rendering index
(CRI) when operated in a dimmed mode. Some restrictions apply to both the
operation of the ballast and lamp. For more information on dimming, please
reference NEMA guidelines or contact a SYLVANIA representative.
2.5 hours / start - Approximately 55% of rating
1.25 hours / start - Approximately 40% of rating
BASE
Most SYLVANIA HID lamp bases for general lighting are made of corrosionresistant brass with special lubricant to provide easy removal at end of lamp life.
See the following pages for all base illustrations.
FIXTURE REQUIREMENT
Developed by the American National Standard Institute (ANSI), the fixture
requirement code describes the type of fixture required for each lamp type. See
lamp warnings for additional information and proper operating instructions.
E = Lamps classified as E-type are to be used only in suitably rated enclosed
luminaires.
E26 Medium - Medium (MED) bases are used on lamps in E17 bulbs and are
limited to 175W maximum.
O = Lamps classified as O-type, comply with ANSI Standard C78.389 for
containment testing and may be used in open luminaires.
E26 Medium Skirted - Medium skirted (Med. Skt.) bases consist of a medium
brass base with a skirt, which is mechanically connected to a PAR38 bulb.
S = When operated within 15 degrees of vertical, this lamp may be operated
in an open luminaire provided the installation is not near people or flammable
or combustible material, otherwise it must be operated in a suitably enclosed
luminaire.
E39 Mogul - All (MOG) bases are embossed with letters and numbers
representing months and years. The date of installation can be recorded by
marking the letter of the current month and the number that coincides with
the last digit of the current year.
EX39 Exclusionary Mogul Base - Exclusionary Mogul bases (EXCL MOG) are
bases used on metal halide lamps having shrouded arc tubes, permitting
them to be used in open fixture applications. These bases are compatible
with exclusionary or standard mogul sockets.
E39 POM - Position Oriented Mogul (POM) bases are used on lamps
designed to operate only in the horizontal position and require a special POM
socket. A pin located on the base engages in a slot within the POM socket
ensuring proper operating position of the lamp within the fixture.
For more complete product information visit www.sylvania.com
F = F-rated lamps require an enclosed fixture with a U.V filter and lens
interlock.
The 2005 NEC requires that luminaires which use a metal halide lamp shall be
provided with either a containment barrier that encloses the lamp (historically
referred to as an enclosed luminaire) or shall be provided with a means, typically
a special lampholder, that will only accept an ANSI Type-O metal halide lamp.
(Exception: This requirement will not apply to open luminaires with thick-glass
parabolic reflector PAR lamps.)
Symbols/Footnotes on page 101-102
75
040_HID_drop.qxd
12/12/07
3:14 PM
Page 76
UNDERSTANDING HIGH INTENSITY DISCHARGE LIGHTING (continued)
FIXTURE REQUIREMENT (continued)
LUMENS
The 2005 NEC also requires that metal halide luminaires for new contruction/major renovations in the playing and spectator areas of indoor sports,
mixed use, and all purpose facilities, which are subject to physical damage,
must be of a type that protects the lamp with a glass or plastic lens. Open
luminaires will not be permitted. The use of self-extinguishing lamps is still
recommmended and permitted for all existing installations.
Initial lumen ratings are based on photometry under controlled conditions of at
least 10 hours per start in the prescribed position at rated lamp wattage after
100 operating hours. HQI®, LUMALUX® Super and SOX lamp ratings are based
on measurements at constant input voltage. Lamp performance under typical
service conditions may vary from rated values. Operating universal METALARC®
lamps in off-vertical positions will result in reduced lumen output.
Mean lumens are measured on ANSI reference circuits at rated wattage (HQI,
LUMALUX Super and SOX lamp ratings are based on input voltage) at 40% of
average rated life except for those lamps with a "+" next to their life rating;
these lamps are measured at 50% of average rated life. All measurements are
based on ballast operation on systems with current crest factors of 1.8 or less.
Higher current crest factors reduce values. In actual applications on CW or
CWA ballasts, mean lumens may be higher than published ratings.
For more information regarding the use of Type-O, S, and E metal halide systems, please refer to the NEMA white paper on this subject that is freely available at nema.org.
HOT RESTRIKE
H
I
D
In most instances, if an HID lamp experiences a momentary power interruption or sudden voltage drop, the lamp may extinguish. A lamp that is still hot
will not restart immediately. Because the arc tube within the lamp must cool
down before it can re-start, HID lamps have hot restrike times ranging from
1-15 minutes depending on the product type.
Unless otherwise noted, all photometry measurements are made on an ANSI
reference ballast at rated lamp wattage.
MAXIMUM OVERALL LENGTH (MOL)
The maximum overall length of single-ended lamps is the maximum distance
from the top of the bulb to the bottom of the base. For double-ended lamps,
it is the maximum distance from end-to-end (excluding any leadwires).
KEY TO DATE OF MANUFACTURE
Consult your SYLVANIA Sales Representative or call 1-800-LIGHTBULB.
LAMP WARNINGS
ORDERING ABBREVIATION
HID Metal Halide and Mercury lamps are marked with a “T” or “R” on their
packaging. These letters provide safety information about the lamp. Below is
the text used by the FDA to describe each of the letters.
Ordering abbreviation provides a shorthand description of the lamp, using a
unique code which can be used when ordering a lamp if you do not know the
product number. This information can be found on the lamp etch.
T: WARNING: This lamp should self-extinguish within 15 minutes after the
outer envelope is broken or punctured. If such damage occurs, TURN OFF
AND REMOVE LAMP to avoid possible injury from hazardous shortwave
ultraviolet radiation.
PACKAGE QUANTITY
This identifies the number of lamps contained in a standard shipping carton.
PRODUCT NUMBER
R: WARNING: This lamp can cause serious skin burn and eye inflammation
from shortwave ultraviolet radiation if outer envelope of the lamp is broken
or punctured. Do not use where people will remain for more than a few
minutes unless adequate shielding or other safety precautions are used.
Lamps that will automatically extinguish when the outer envelope is broken
or punctured are commercially available.
Product number is a five digit number used to identify a specific SYLVANIA
lamp and should be used when ordering.
WARM UP TIME
Most HID lamps do not have instant on capabilities. It may take several minutes for the arc tube to stabilize before optimal light output is achieved.
LIGHT CENTER LENGTH (LCL)
WATTS
The light center length of HID lamps is a measurement from the center of the
arc tube to the bottom of the lamp base.
Watts shown are nominal lamp watts only.
HOW TO READ PRODUCT INFORMATION - HID
4
Product
Number Ordering Abbreviation
ANSI
Ballast Pkg
Code Qty
Lamp Operating
Finish Position
Avg
Fix Rated
Approx Lumens
CCT
Req Life(hrs) (initial) (mean) CRI (K)
Clear Universal
O
Watts
Bulb
Base
100
E17
E26 Med 67506
LU100/MED
S54
320
BT37
E39 Excl
Mogul
MCP320/C/PS/BU-ONLY/
840/BT37 PB
M154/O 6
360
BT37
E39 Mogul 64655
MS360/SS/BU-HOR
1000
BT37
E39 Mogul 64351
M1000/PS/U/BT37
64851
20
Symbols &
Footnotes
|
|
|
5,34
24000+
9500
8000
22 2100
Coated Base up within O
15˚ only
20000
36000
27000
88 3900 1,10,11,13
M59/S 6
Clear BU-HOR
S
20000V 36000V 23500V 65 4000
15000H 30000H 19000H
M141/E 6
Clear Universal
E
20,23,24
15000V 110000V 96000V 65 3800 2,10
9000H 107800H86300H
Please refer to the "Understanding High Intensity Discharge" section on previous pages for definitions and explanations of the category headers.
HOW TO READ ORDERING ABBREVIATIONS
MS360/SS/BU-HOR
MCP320/C/PS/BU-ONLY/840/BT37 PB LU100/D/MED
H39KC-175/DX
MS
360
SS
BU-HOR
MCP
H39
175
DX
Super METALARC
Wattage
SUPERSAVER
Operating Position:
Base up through
Horizontal
320
C
PS
BU-ONLY
840
BT37
PB
For more complete product information visit www.sylvania.com
76
Metalarc Ceramic
Pro-Tech
Wattage
Coated
Pulse Start
Operating Position:
Base up only
80+ CRI; 4000 CCT
Bulb Type
Powerball
LU
100
D
MED
Lumalux®
Wattage
Coated
Medium Base
ANSI Ballast Number
Wattage
Brite White
Deluxe Coated
Symbols/Footnotes on page 101-102
040_HID_drop.qxd
12/12/07
3:14 PM
Page 77
BULBS
A bulb designation consists of a letter(s) to indicate the shape and a
number(s) to indicate the approximate maximum diameter in eighths of
an inch. Thus, an E17 lamp is an
Ellipsoidal shape and 17/8 of an inch
or 2 1/8 inches in diameter. Other letter designations include: BT=Bulbous
Tubular; E or ED=Ellipsoidal;
ET=Ellipsoidal Tubular;
PAR=Parabolic; R=Reflector;
T=Tubular.
E17
ET18
ET23.5
E25
ED37
BT28
T J Base
R30
R40
T
RSC base
G12
E26
BT37
PAR20
BT56
PAR30 LN
PAR38
T Ceramic
Spade
T
G12 base
T
G8.5 base
T
Mogul base
H
I
D
T
BY22d base
BASES
Lamps with screw bases have one
lead-in wire soldered or welded to the
center contact and the other soldered
or welded to the upper rim of the
base shell.
Bases with ceramic bodies have internal leads welded to either silver-plated
contacts or external lead wires.
G8.5
BY 22 d
Ceramic
#8 - #10
Spade
E26
E39
J
E38
RRSC
EX39
E26
RSC
OPERATING POSITIONS
A designated operating positions
assure maximum lamp performance.
Where it is not specified, the lamp is
suitable for operation in any position.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
77
040_HID_drop.qxd
12/12/07
3:14 PM
Page 78
HID BRAND NAME GUIDE
Note: These tables are intended only as guides and may represent another lamp company’s most similar product or product family rather
than an identical match. Individual manufacturer’s performance values should be consulted. BRAND NAME GUIDE
SYLVANIA
GE *
METALARC®
Multi-Vapor
METALARC Powerball® ConstantColor CMH
Protected Multi-Vapor
METALARC PRO-TECH®
Super METALARC
High Output Multi-Vapor
METALARC Pulse Start PulseArc Multi-Vapor
H
I
D
Watt-Miser High Output
METALARC Super Saver Multi-Vapor
METALARC Briteline
®
HQI
PHILIPS **
SYLVANIA
Metal Halide
MasterColor
Protected Metal
Halide
Metal Halide
Pulse Start Metal
Halide
LUMALUX®
LUMALUX / ECO®
LUMALUX PLUS®/ ECO
Lucalox
Ecolux
Ecolux NC
LUMALUX Standby
Standby Longlife Lucalox
UNALUX®
SOX Low Pressure
Sodium
E-Z Lux
SOX Low Pressure
Sodium
Metal Halide
Double-Ended
Metal Halide
Double-Ended
Metal Halide
Safety Lifeguard
Metal Halide
SportsLighting
Arcstream
METALARC SAFELINE® Saf-T-Gard Multi-Vapor
GE *
PHILIPS **
Ceramalux
Ceramalux ALTO
Ceramalux ALTO NC
Ceramalux Instant
Restrike
Ceramalux
RetroLux
SOX Low Pressure
Sodium
**Trademark or registered trademark of Philips.
*Trademark or registered trademark of General Electric Company.
PHYSICAL DIMENSIONS
BRITELINE
Bulb
T7
T8
T9
HQI
Bulb
T6
T7
T7.5
R30
PHYSICAL SIZE
(dimensions in mm)
METALARC METAL HALIDE
LCL
127
127
127
MOL
256
254
254
Physical size of all Metalarc lamps
PHYSICAL SIZE
(dimensions in mm)
LCL
57
66
56
--
MOL
114
132
84
3.5
MERCURY VAPOR
Bulb
E17
ET23.5
ED28
ED37
BT56
PAR38
R40 (100W)
R40 (175W)
(dimensions in inches)
LCL
3.75
5
5
7
9.5
----
MOL
5.44
7.5
8.31
11.5
15.38
5.44
5.44
7.5
For more complete product information visit www.sylvania.com
78
9
8
7
LCL
2
3.4
5.75
6.14
4.49
5
7
9.5
2.2
2.25
2.2
----
LUMALUX HIGH PRESSURE SODIUM
MOL
3.19
5.44
9.75
9.75
6.97
8.31
11.5
15.38
3.94
4.5
4.13
3.65
4.76
5.32
(dimensions in inches)
Physical size of all LUMALUX and UNALUX lamps
MOL
01
Bulb
T4.5/TC
E17/ED17
ET18 (250W)
ET18 (400W)
ET23.5
BT28/ED28
BT37
BT56
T6
T6 (DE)
T7.5
PAR20
PAR30LN
PAR38
(dimensions in inches)
6
5
4
3
2
1
Bulb
T7
T14.5
E17
ET18
ET23.5
E25
BT28
BT28 (UNALUX)
BT37
LCL
5
6.89
3.43
5.75
5
8.75
5
5
7
MOL
10.06
11.22
5.43
9.75
7.75
15.08
8.98
8.31
11.5
Symbols/Footnotes on page 101-102
040_HID_drop.qxd
12/12/07
3:14 PM
Page 79
The following items were accepted into the 2006 IESNA Progress Report, which recognizes innovative products
introduced to the industry during that year.
20-watt PAR30 METALARC POWERBALL
39-watt PAR20 METALARC POWERBALL
39-watt PAR30 METALARC POWERBALL
750-watt METALARC Metal Halide
H
I
D
LAMP DISPOSAL LABELING
The following information appears on the packages of high intensity discharge lamps that contain mercury. For more information on lamp
disposal labeling, see the inside back cover of this catalog.
Hg
Lamp Contains Mercury
Manage in accordance with disposal laws
See www.lamprecycle.org or 1-866-666-6850
For weight and measure information, please visit www. sylvania.com
For more information about HID lamp warranties, please visit the warranty section of this catalog.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
79
040_HID_drop.qxd
12/12/07
3:14 PM
Page 80
GUIDE TO METAL HALIDE LAMPS
METALARC® Metal Halide lamps are designed for general lighting
applications such as commercial, industrial lighting and outdoor
floodlighting where good color and high efficiency are desired. OSRAM
SYLVANIA currently offers ten families of Metal Halide lamps:
STANDARD METALARC(M) — Offered in a range of wattages (from 1751500 watts), standard METALARC metal halide lamps allow for design flexibility with multiple light source solutions to choose from. METALARC
lamps have significantly higher efficacy than mercury vapor or incandescent
products and considerably better CRI than mercury vapor and high pressure
sodium lamps.
H
I
D
COMPACT METALARC(M/BT##) — These lamps have reduced outer jacket
sizes compared to standard metal halide lamps for use in smaller fixtures.
The reduced bulb diameter allows fixture manufacturers to design more versatile, less expensive and highly efficient luminaries.
SUPER METALARC(MS) — Super METALARC lamps are position dedicated,
which means that they are specifically designed to be run in particular operating positions. Because of this feature, these lamps exhibit improved performance over standard, universal operating metal halide lamps of similar
wattage. Product features include long life, higher maintained lumens and
increased efficacy.
METALARC PRO-TECH®(MP) — These are specially designed lamps that incorporate a protective shroud to contain a non-passive arc tube
failure. Metalarc Pro-Tech lamps can be used in open or enclosed fixtures. Dedicated bases are standard on both low and high wattage lamp types.
METALARC POWERBALL® CERAMIC(MC or MCP) — POWERBALL lamps use a patented round ceramic arc tube, which allows for a more
uniform arc tube temperature, higher color rendering (>85), and improved color consistency. These lamps are ideal for applications that
demand the best in color performance.
METALARC PULSE START(M/PS) — METALARC Pulse Start lamps utilize metal halide performance with proven ignitor technology for longer
life, improved lumen maintenance and reduced color shift over lamp life compared to standard metal halide products. Lamp configurations
include low and high wattage types, both clear and coated. METALARC PRO-TECH designs are also available for open fixture applications. All
METALARC products lower than 150-watts and all METALARC POWERBALL products utilize Pulse Start technology exclusively.
METALARC SUPERSAVER®(M/SS)— Constructed with an enhanced arc tube for peak performance, METALARC SUPERSAVER lamps are
designed as energy-saving, replacement metal halide lamps. The 360W SUPERSAVER lamp is a direct retrofit for existing 400W products, the
950W SUPERSAVER replaces 1000W lamps, and the 150W SUPERSAVER replaces 175 W lamps -- no ballast change is required.
METALARC BRITELINE(M) — These double-ended lamps are designed for compact fixtures, which provide excellent optical control and high
efficiency. These higher wattage lamps are particularly well suited for sports lighting and outdoor floodlighting applications.
METALARC SAFELINE®(MT) — METALARC SAFELINE lamps are designed to self-extinguish when the outer bulb is broken reducing exposure
to possible ultraviolet radiation. These lamps are recommeded for use in sports facilities and other places of public assembly where the lamps
may be subject to breakage by external objects.
HQI® — With their compact size and very short arc length, HQI metal halide lamps allow luminaire manufacturers to design highly efficient fixtures using proven quartz arc tube technology.
For more complete product information visit www.sylvania.com
80
Symbols/Footnotes on page 101-102
040_HID_drop.qxd
12/12/07
3:14 PM
Page 81
Enclosed fixture rated METALARC®, E-Type Lamp
R
ANSI Luminaire Code E
ENCLOSED FIXTURE
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
RUPTURE RISKS: This Metal Halide lamp is constructed of a UV-attenuating outer quartz bulb with an internal arc-tube. Metal Halide arc-tubes operate at high
pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arctube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture,
THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2192°F, 1200°C for a ceramic arc tube
and 2012°F, 1100°C for quartz). If you are uncertain, contact your fixture manufacturer.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H
I
D
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE
RUPTURE ARE AVAILABLE.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. All horizontal lamps with position oriented mogul (POM) bases (with locating pin) require a POM socket. Do not remove pin from base.
3. All pulse start lamps require a socket rated to withstand a 4000 volt pulse.
4. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
81
040_HID_drop.qxd
12/12/07
3:14 PM
Page 82
Enclosed fixture rated METALARC® E-Type (Ceramic & Quartz, G12, G8.5 & DE, UV-Stop Outer-jacket) Lamp
R
ANSI Luminaire Code E
ENCLOSED FIXTURE
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal ceramic or quartz arc-tube. Metal Halide arc-tubes operate at high
pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arctube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture,
THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2192°F, 1200°C for a ceramic arc-tube
and 2012°F, 1100°C for quartz). If you are uncertain, contact your fixture manufacturer.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H
I
D
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Ensure that lamp is securely seated in the socket.
2. All sockets must be rated to withstand the maximum pulse voltage output of the ballast.
3. Never install the lamp into an ordinary household socket or a fixture intended for tungsten halogen lamps.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
82
Symbols/Footnotes on page 101-102
040_HID_drop.qxd
12/12/07
3:14 PM
Page 83
Open Fixture Rated, METALARC PRO-TECH®, O-Type Lamp
R
ANSI Luminaire Code O
OPEN FIXTURE permissible
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at
very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can
burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate with compatible ballast and fixture. (See catalog for specific information.)
2. Only operate lamp in designated operating positions. (See catalog for illustration.)
3. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
4. Never expose operating lamp to moisture (such as rain, sleet or snow).
5. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
6. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.
7. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H
I
D
This lamp is intended for use in open fixtures since it contains a special shield which was designed to contain a ruptured arc-tube and thereby minimize the resultant risks of personal injury, property damage, burns and fire. In applications where an additional measure of safety is desired, an enclosed fixture may be used
with a lens/diffuser material able to contain hot lamp fragments (up to 2192°F, 1200°C for a ceramic arc tube and 2012°F, 1100°C for quartz). If you are uncertain,
contact your fixture manufacturer.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. All pulse start lamps require a socket rated to withstand a 4000 volt pulse.
3. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
83
040_HID_drop.qxd
12/12/07
3:14 PM
Page 84
METALARC®, S-Type Lamp
R
ANSI Luminaire Code S
ENCLOSED FIXTURE/Open if meets
requirement of Paragraph I.1 below
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at
very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can
burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer. When operated within 15° of vertical, this lamp may be operated in an open fixture PROVIDED THE INSTALLATION IS
NOT NEAR PEOPLE OR FLAMMABLE OR COMBUSTIBLE MATERIAL.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H
I
D
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE
RUPTURE ARE AVAILABLE.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. All horizontal lamps with position oriented mogul (POM) bases (with locating pin) require a POM socket. Do not remove pin from base.
3. All pulse start lamps require a socket rated to withstand a 4000 volt pulse.
4. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
84
Symbols/Footnotes on page 101-102
040_HID_drop.qxd
12/12/07
3:14 PM
Page 85
METALARC® SAFELINE®, S-Type Lamp
T
ANSI Luminaire Code S
ENCLOSED FIXTURE/Open if meets
requirement of Paragraph I.1 below
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at
very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can
burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer. When operated within 15° of vertical, this lamp may be operated in an open fixture PROVIDED THE INSTALLATION IS
NOT NEAR PEOPLE OR FLAMMABLE OR COMBUSTIBLE MATERIAL.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H
I
D
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE
RUPTURE ARE AVAILABLE.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III ULTRAVIOLET RADIATION EXPOSURE: This lamp should self-extinguish within 15 minutes after the outer envelope is broken or punctured. If such damage
occurs, TURN OFF AND REMOVE LAMP to avoid possible injury from hazardous shortwave ultraviolet radiation. This product conforms to the following federal
regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
85
040_HID_drop.qxd
12/12/07
3:14 PM
Page 86
METALARC® BRITELINE, F-Type Lamp
ANSI Luminaire Code F
ENCLOSED FIXTURE with UV
filter and lens interlock required
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
RUPTURE RISKS: This Metal Halide lamp is constructed with a quartz arc-tube which operates at high pressure and at very high temperatures. The arc-tube can
unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication resulting in the discharge of glass fragments and
extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in horizontal position. (See catalog for allowable deviation from horizontal.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if bulb is scratched, cracked or damaged in any way.
7. Keep all metals at least 3 inches from the body of the arc tube to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H
I
D
II. ULTRAVIOLET RADIATION HAZARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 3 PER ANSI-IESNA Rp-27.396. THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INJURY FROM SHORTWAVE ULTRAVIOLET RADIATION. IT MUST BE OPERATED IN AN ENCLOSED
FIXTURE WHICH FILTERS OUT THE HARMFUL SHORTWAVE ULTRAVIOLET RADIATION. IF YOU ARE UNCERTAIN, CONTACT YOUR FIXTURE MANUFACTURER.
A power interlock device is required to automatically turn off the lamp if the fixture assembly is opened. It is strongly recommended that a power interlock device
also turn off power to the lamp if the fixture lens is broken. If the fixture lens breaks and the lamp remains on, turn off power immediately and repair before reenergizing.
This lamp is to be used ONLY in a fixture specifically designed for use with this lamp and recommended for its use by the equipment manufacturer.
III. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing.
IV. LAMP INSTALLATION AND FIXTURE: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled,
fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and
premature lamp failure. Dry lamp carefully with clean cotton cloth.
1. Install lamp without undue pressure.
2. Ensure that lamp electrical connections are secure and nothing is touching bulb.
3. All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp.
4. Fixture wiring must have a temperature rating of 250° C and a minimum voltage rating of 600 V RMS for all lamps except the 1500T7 lamp which must have
a voltage rating of 1500V RMS.
5. For maximum performance, all double-ended lamps must be operated with the arc-tube tip up.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
86
Symbols/Footnotes on page 101-102
040_HID_drop.qxd
12/12/07
3:14 PM
Page 87
GUIDE TO HIGH PRESSURE SODIUM LAMPS
DOME MOUNT SUPPORT
HERMETIC
END SEAL
STEEL
FRAME
ALUMINA ARC-TUBE
WEATHER RESISTANT
GLASS ENVELOPE
VACUUM
RESIDUE GAS GETTER
BRASS DATE
RECORDING BASE
High Pressure Sodium lamps are one of the most efficient HID sources available today. These lamps are used for general lighting applications where high
efficiency and long life are desired while color rendering is not critical. Typical
applications include street lighting, parking lot lighting, building floodlighting
and general area lighting.
LUMALUX PLUS® / ECO® AND LUMALUX PLUS® — These environmentally
friendlier lamps contain significantly less Mercury than standard high pressure
sodium lamps. They will not cycle at the end of life and are rated for 30,000
hours life. All lamps operate on existing high pressure sodium ballasts.
LUMALUX Plus / ECO lamps are designed with lead-free bases and they pass
the existing Federal TCLP limits.*
LUMALUX® AND LUMALUX / ECO — Available in a broad range of wattages, in
both clear and coated configurations, LUMALUX and LUMALUX / ECO lamps
are ideal for a variety of applications. LUMALUX medium based lamps are
available in wattages ranging from 35-150 watts while mogul based lamps are
offered in 50-1000 watts. The mogul based LUMALUX / ECO lamps operate
on standard high pressure sodium ballasts and pass the Federal TCLP test.*
LUMALUX STANDBY — These lamps are designed with two arc tubes to provide instant restrike capability in the event of a momentary power interruption.
With almost twice the life of standard high pressure sodium lamps, LUMALUX
Standby lamps are a great way to reduce maintenance costs.
SOX — These energy efficient low pressure sodium lamps emit a characteristic yellow light that is ideal for certain exterior street and area lighting.
* based on NEMA LL Series Standards
WARNING
LUMALUX, LUMALUX / ECO, LUMALUX PLUS / ECO, AND LUMALUX STANDBY LAMPS
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY:
This lamp must be operated in a fixture and ballast which has an ANSI designation identical to that found on the lamp outer glass bulb. (with the exception of the
LU/PLUS on Cooper ignitor 220C173G11, which may have compatibility issues).
II. ELECTRICAL SHOCK AND BURN HAZARD:
Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled.
III. INSTALLATION AND OPERATING INSTRUCTIONS:
See catalog for specific operating parameters.
1. A specially designed socket which is electrically rated to withstand a 4000 volt pulse is required for all High Pressure Sodium lamps except for the 750 and
1000 watt lamps which require a socket rated to withstand a 5000 volt pulse.
2. These lamps have a vacuum jacket and may implode if broken. For added safety, wear safety glasses and gloves when installing or removing lamps.
3. To avoid burn injury, allow lamp to cool before removing from fixture.
4. Screw lamp firmly but not forcibly into socket to avoid breakage.
5. Replace lamps at or before end of rated life. (See catalog for rated life.)
6. Never install it into an ordinary household socket.
7. This lamp may be operated in any position.
IV. PROPER CARE AND MAINTENANCE:
To reduce the possibility of a rupture and premature lamp failure:
1. Do not use with luminaires which would cause an excessive increase in arc-tube operating voltage.
2. Do not expose operating lamp to moisture (such as, rain, sleet or snow).
3. Replace lamp if outer glass bulb has been scratched, cracked, or damaged in any way.
4. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
87
H
I
D
040_HID_drop.qxd
12/12/07
3:14 PM
Page 88
WARNING
LUMALUX® Double-Ended Quartz Jacketed Lamps
I.
ANSI LUMINAIRE Code F
ENCLOSED FIXTURE with UV
Filter and lens interlock required
OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY: This lamp must be operated in a fixture and ballast which has an ANSI designation identical to
that found on the lamp outer glass bulb.
II. ULTRAVIOLET RADIATION HAZARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 2 PER ANSI-IESNA Rp-27.396. THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INJURY FROM SHORTWAVE ULTRAVIOLET RADIATION. IT MUST BE OPERATED IN AN ENCLOSED
FIXTURE WHICH FILTERS OUT THE HARMFUL SHORTWAVE ULTRAVIOLET RADIATION. IF YOU ARE UNCERTAIN, CONTACT YOUR FIXTURE MANUFACTURER.
A power interlock device is required to automatically turn off the lamp if the fixture assembly is opened. It is strongly recommended that a power interlock device
also turn off power to the lamp if the fixture lens is broken. If the fixture lens breaks and the lamp remains on, turn off power immediately and repair before reenergizing.
H
I
D
This lamp is to be used ONLY in a fixture specifically designed for use with this lamp and recommended for its use by the equipment manufacturer.
III. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing.
IV. LAMP INSTALLATION AND FIXTURE: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled,
fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and
premature lamp failure. Dry lamp carefully with clean cotton cloth.
1.
2.
3.
4.
5.
6.
7.
Install lamp without undue pressure.
Ensure that lamp electrical connections are secure and nothing is touching bulb.
All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp.
Fixture wiring must have a temperature rating of 250° C and a minimum voltage rating of 600 V RMS.
Never install it into a fixture designed for use with tungsten halogen lamps.
Do not expose operating lamp to moisture (such as rain, sleet or snow).
Replace lamp if outer glass bulb has been scratched, cracked, or damaged in any way.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
R
SOX LAMPS
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE
I.
BURNS AND FIRE HAZARD:
Sox lamps contain a quantity of sodium which may heat from a reaction with moisture in the air or on the skin if a lamp is broken. Hot sodium will burn spontaneously when exposed to the air. Sodium lamps must be packed, shipped, and stored in the wrapping provided to reduce the risk of breakage.
II. IMPLOSION HAZARD:
Always wear safely glasses when handling lamp. Low pressure sodium lamps are made of glass and are evacuated and could therefore implode if damaged or
handled incorrectly. Replace lamp if outer glass bulb has been scratched, cracked, or damaged in any way. To reduce the possibility of a lamp cracking or breaking, do not expose operating lamp to rain, snow, or water.
III. ELECTRICAL SHOCK AND BURN HAZARD:
Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled.
IV. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY:
This lamp must be operated in a fixture and ballast which was specifically designed for use with this lamp.
V. INSTALLATION AND OPERATING INSTRUCTIONS:
1. When operated in other than the base up orientation, single-based "SOX" lamps of from 35 watts to 180 watts must be supported at the end opposite to the
base in such a way as to allow for thermal expansion and contraction along the lamp axis.
2. Install lamp firmly but not forcibly into socket to avoid breakage.
3. For maximum system performance, replace lamp at or before end of rated life. (See catalog for rated life.)
4. Only operate lamps in designated operating positions. (See catalog for illustration.)
VI. LAMP DISPOSAL:
To avoid the risk of personal injury or property damage from sodium reaction when disposing of spent lamps, the following procedure should be followed:
1. Before commencing, operator must be outfitted with appropriate OSHA-approved face mask, gloves and apron.
2. Place no more than 20 lamp(s) in a large, dry container. (Do not exceed one-quarter of the container height.)
3. Break lamp(s) into small pieces inside the container in a dry atmosphere and in a well ventilated area.
4. From a safe distance, carefully pour enough tap water into container to cover all materials.
5. After a few minutes, the reaction of the sodium with the large quantity of water will produce a mild sodium hydroxide solution which may be disposed of in
accordance with applicable federal, state and local regulations.
For more complete product information visit www.sylvania.com
88
Symbols/Footnotes on page 101-102
040_HID_drop.qxd
12/12/07
3:14 PM
Page 89
GUIDE TO MERCURY VAPOR LAMPS
OSRAM SYLVANIA Mercury lamps are designed primarily for use in general lighting applications where good efficiency and long life are desired while color rendering requirements are moderate. Applications include street lighting, industrial
hi-bay, parking lot lighting, and general flood-lighting.
STANDARD MERCURY — Available in a wide range of lamp types from 75-1000
watts, in both clear and coated configurations, Mercury vapor lamps are ideal for
a variety of lighting applications. PAR lamps offer floodlighting and ultra-violet
spectra for special lighting applications.
H
I
D
WARNING
STANDARD MERCURY “R” LAMPS
I.
RUPTURE RISKS: This Mercury lamp is constructed of an outer glass bulb with an internal arc-tube made of quartz. Mercury arc-tubes operate at high pressure
and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot quartz particles. In the event of such rupture,
THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
2. Fixture lens/diffuser material must be able to contain hot lamp fragments (as high as 1832˚F, 1000˚C). If you are uncertain, contact your fixture
manufacturer.
3. Never expose an operating lamp to moisture (such as rain, sleet, or snow).
4. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
5. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
6. Replace lamp at or before the end of rated life. (See catalog for rated life.)
II.
ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INFLAMMATION FROM SHORT WAVE ULTRAVIOLET RADIATION IF OUTER
ENVELOPE OF THE LAMP IS BROKEN OR PUNCTURED. DO NOT USE WHERE PEOPLE WILL REMAIN FOR MORE THAN A FEW MINUTES
UNLESS ADEQUATE SHIELDING OR OTHER SAFETY PRECAUTIONS ARE USED. LAMPS THAT WILL AUTOMATICALLY EXTINGUISH WHEN THE
OUTER ENVELOPE IS BROKEN OR PUNCTURED ARE COMMERCIALLY AVAILABLE.
THIS PRODUCT CONFORMS TO THE FOLLOWING FEDERAL REGULATIONS:
U.S.A.: 21 CFR 1040.30
CANADA: SOR/80-381
IV. INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. To avoid damaging a lamp, never install it into an ordinary household socket.
3. This lamp may be operated in any position.
V.
BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
89
040_HID_drop.qxd
12/12/07
3:14 PM
Page 90
GUIDE TO REPROGRAPHIC LAMPS
TUNGSTEN
ELECTRODES
QUARTZ BULB
MOLYBDENUM
FOIL
OSRAM SYLVANIA reprographic lamps are
designed for applications other than general
lighting. These applications include: plate making,
photo resist exposure, imaging and other
requiring the use of ultraviolet energy.
BASE
H
I
D
UNJACKETED REPROGRAPHIC F-TYPE LAMP
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I.
RUPTURE RISKS: This High Intensity Discharge (HID) lamp is constructed with a quartz arc-tube which operates at high pressure and at very high temperatures.
The arc-tube can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer.
2. Only operate lamp with compatible ballast (including capacitor and ignitor) and fixture.
3. Only operate lamp in horizontal position (Maximum deviation from horizontal is 15°).
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if bulb is scratched, cracked or damaged in any way.
7. Keep all metals at least 3 inches from the body of the arc-tube to avoid glass decomposition.
8. Do not operate lamps when output radiation falls below 75% of its initial value.
II. ULTRAVIOLET RADIATION HAZARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 3 PER ANSI-IESNA Rp-27.396. THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INFLAMMATION FROM SHORTWAVE ULTRAVIOLET RADIATION. KEEP OUT OF DIRECT OR INDIRECT LIGHT DURING OPERATION UNLESS APPROPRIATE EYE AND SKIN PROTECTION IS WORN. A POWER INTERLOCK DEVICE IS RECOMMENDED TO AUTOMATICALLY TURN OFF THE LAMP IF THE FIXTURE ASSEMBLY IS OPENED.
DUE TO THE ULTRAVIOLET HAZARD, THIS LAMP IS TO BE USED ONLY IN EQUIPMENT SPECIFICALLY DESIGNED FOR USE WITH THIS LAMP AND RECOMMENDED FOR ITS USE BY THE EQUIPMENT MANUFACTURER.
III. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing.
IV. LAMP INSTALLATION AND FIXTURE: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled,
fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and
premature lamp failure. Dry lamp carefully with clean cotton cloth.
1. Install lamps without undue pressure.
2. Ensure that lamp electrical connections are secure and nothing is touching bulb.
3. The seal base temperature must not exceed 350° C and the bulb wall temperature, as measured in center, must be maintained between 600° C and 700° C.
4. If cooling is required to maintain the seal/base and the bulb wall temperatures of item 3 above, air interlock vane switches are recommended to protect against
fan-motor failure.
5. All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp.
6. Fixture wiring must have a temperature rating of 250° C and a minimum voltage rating of 600V RMS for lamps of less than 1000 watts and 1500V RMS for
lamps of 1000 watts or greater.
7. For maximum performance, all double-ended lamps must be operated with the arc-tube tip up.
V.
BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
For more complete product information visit www.sylvania.com
90
Symbols/Footnotes on page 101-102
040_HID_F_print.qxd
T (G8.5 base)
12/17/07
8:29 AM
T (G12 base), T (G22 base)
Page 91
T (RSC base)
PAR30 LN
PAR20
POWERBALL® CERAMIC METALARC® TUBULAR SINGLE-ENDED
High CRI, Pulse Start, UV Stop – Enclosed Fixtures Only
4
Watts Bulb
Base
Product
Number Ordering Abbreviation
20
G8.5
64882
T4.5
MC20TC/U/G8.5/830PB
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
M156/E
12 Clear
Universal E
12000
1700
1275
83 3000
|
|
|
1,4,18,
24,25,30,48
39
T4.5
G8.5
64791
MC39TC/U/G8.5/830PB
M130/E
12 Clear
Universal E
12000
3400
2720
82 3000
1,4,18,24,
25,30,48
T6
G12
64363
MC39T6/U/G12/830PB
M130/E
12 Clear
Universal E
12000
3400
2720
82 3000
1,4,18,24,
25,30,48
64325
MC39T6/U/G12/940PB
M130/E
12 Clear
Universal E
12000
3300
2640
90 4200
1,4,18,
H
I
D
24,25,26,30,48
70
T4.5
G8.5
64825
MC70TC/U/G8.5/930PB
M139/E,
M98/E
12 Clear
Universal E
12000
6300
5040
95 3000
T6
G12
64361
MC70T6/U/G12/830PB
M139/E,
M98/E
12 Clear
Universal E
12000
7000
5600
87 3000
M139/E,
M98/E
12 Clear
M139/E,
M98/E
12 Clear
M102/E,
M142/E
12 Clear
M102/E,
M142/E
12 Clear
M80/E
10 Clear
64200
64338
150
T7.5
G12
64359
64337
250
T9
G22
64167
MC70T6/U/G12/930PB
MC70T6/U/G12/940PB
MC150T7.5/U/G12/830
MC150T7.5/U/G12/940PB
MC250T9/U/G22/830PB
1,4,18,
24,25,26,30,48
1,4,18,24,
25,26,30,48
Universal E
12000
6400
5120
95 3000
1,4,18,
24,25,26,30,48
Universal E
12000
6700
5360
93 4200
1,4,18,24,
25,26,30,48
Universal E
12000
15500
12400
89 3000
1,4,18,24,
30,31,48
Universal E
12000
14500
11600
95 4200
1,4,18,24,
30,31,48
Universal E
12000
24500
19600
86 3000
1,4
,18,24,30,31,48
POWERBALL® CERAMIC METALARC® TUBULAR DOUBLE-ENDED
4
Watts Bulb
Base
Product
Number Ordering Abbreviation
70
RX7s RSC
64793
150
T6
T7.5
RX7s RSC
64794
MC70T6/DE/830PB
MC150T7.5/DE/830PB
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
ANSI
Code
M139/E,
M85/E,
M98/E
12 Clear
M102/E,
M142/E,
M81/E
12 Clear
HOR ± 45° E
12000
6900
5520
88 3000
|
|
|
1,4,18,25,
26,30,35,48
HOR ± 45° E
12000
14800
11840
91 3000
1,4,18,30,
37,48
POWERBALL® CERAMIC METALARC® PAR
High CRI, Pulse Start, UV Stop – Open or Enclosed Fixtures
5
Watts Bulb
20
Base
PAR30LN E26 Med
Product
Number Ordering Abbreviation
64879
ANSI
Code
Avg
Pkg Beam Beam Operating Fix Rated
Qty Type Angle Position Req Life(hrs) MBCP
MCP20PAR30LN/U/830/SP/ECOPB M156/O 6
SP
10°
Universal O
12000
24000
|
|
|
Approx
Lumens
CCT Symbols &
(initial) CRI (K) Footnotes
1200
82 3100
1,4,7,17,24,30,48
64878
MCP20PAR30LN/U/830/FL/ECOPB M156/O 6
FL
30°
Universal O
12000
4000
1200
82 3100
1,4,7,17,24,30,48
39
PAR20
E26 Med
64824
MCP39PAR20/U/830/SPPB
M130/O 12 SP
10°
Universal O
12000
20000
2000
87 3000
1,4,17,
24,25,30,48
64826
MCP39PAR20/U/830/FLPB
M130/O 12 FL
30°
Universal O
12000
5000
2000
87 3000
1,4,17,
24,25,30,48
PAR30LN E26 Med
64880
MCP39PAR30LN/U/830/SP/ECOPB M130/O 6
SP
10°
Universal O
12000
39600
2300
85 3000
1,4,
7,17,24,25,30,48
64881
MCP39PAR30LN/U/830/FL/ECOPB M130/O 6
FL
30°
Universal O
12000
8000
2300
85 3000
1,4,
7,17,24,25,30,48
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
91
040_HID_F_print.qxd
12/17/07
PAR30 LN
8:29 AM
PAR38
Page 92
E17
POWERBALL® CERAMIC METALARC® PAR
High CRI, Pulse Start, UV Stop – Open or Enclosed Fixtures
5
Watts Bulb
39
Base
PAR30LN E26 Med
Product
Number Ordering Abbreviation
64885
ANSI
Code
Avg
Pkg Beam Beam Operating Fix Rated
Qty Type Angle Position Req Life(hrs) MBCP
MCP39PAR30LN/U/830/VWFL/ECOPBM130/O 6
VWFL 46°
Universal O
12000
3500
Approx
Lumens
CCT Symbols &
(initial) CRI (K) Footnotes
2300
85 3000
|
|
|
1,4,
7,17,24,25,30,48
70
PAR30LN E26 Med
64201
64202
PAR38
E26 Med Skt 64749
H
I
D
64750
64751
100
PAR38
E26 Med Skt 64752
64753
64754
150
PAR38
E26 Med Skt 64841
64842
64843
MCP70PAR30LN/U/930/SP/ECOPB M139/O, 6
M98/O
SP
MCP70PAR30LN/U/930/FL/ECOPB M139/O, 6
M98/O
FL
MCP70PAR38/U/830/SP/ECOPB
M139/O, 6
M98/O
SP
M139/O, 6
M98/O
FL
MCP70PAR38/U/830/FL/ECOPB
12°
12000
42000
3600
95 3000
1,4,
7,17,25,26,30,48
30°
Universal O
12000
12000
3600
95 3000
1,4,
7,17,25,26,30,48
15°
Universal O
12000
40000
4300
88 3000
1,4,7,
17,26,30,38,48
25°
Universal O
12000
16000
4300
88 3000
1,4,7,
17,26,30,38,48
MCP70PAR38/U/VWFL/830/ECOPB M139/O, 6
M98/O
VWFL 65°
MCP100PAR38/U/830/SP/ECOPB
M90/O, 6
M140/O
SP
M90/O, 6
M140/O
FL
MCP100PAR38/U/830/FL/ECOPB
Universal O
Universal O
12000
3500
4300
88 3000
1,4,7,
17,26,30,38,48
15°
Universal O
12000
58000
6500
88 3000
1,4,7,
17,27,30,38,48
25°
Universal O
12000
25000
6500
88 3000
1,4,7,
17,27,30,38,48
MCP100PAR38/U/830/VWFL/ECOPBM90/O, 6
M140/O
VWFL 60°
MCP150/PAR38/U/830/SP/ECOPB M102/O, 6
M142/O
SP
MCP150/PAR38/U/830/FL/ECOPB M102/O, 6
M142/O
FL
MCP150/PAR38/U/830/VWFL/ECOPBM102/O, 6
M142/O
VWFL 65°
Universal O
12000
6000
6500
88 3000
1,4,7,
17,27,30,38,48
15°
Universal O
12000
50000
9100
88 3000
1,4,7,
17,31,38,48
25°
Universal O
12000
28000
9100
88 3000
1,4,7,
17,31,38,48
Universal O
12000
6500
9100
88 3000
1,4,7,
17,31,38,48
POWERBALL® CERAMIC METALARC® E17 & HIGH WATTAGE
High CRI, Pulse Start – Open or Enclosed Fixtures
4
Watts Bulb
Base
Product
Number Ordering Abbreviation
50
E26 Med
64840
E17
64849
70
E17
E26 Med
64739
64740
64193
64194
100
E17
E26 Med
64743
64744
64322
64315
MCP50/U/MED/830PB
MCP50/C/U/MED/830PB
MCP70/U/MED/830PB
MCP70/C/U/MED/830PB
MCP70/U/MED/940PB
MCP70/C/U/MED/940PB
MCP100/U/MED/830PB
MCP100/C/U/MED/830PB
MCP100/U/MED/940PB
MCP100/C/U/MED/940PB
For more complete product information visit www.sylvania.com
92
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
ANSI
Code
M110/O,
M148/O
12 Clear
M110/O,
M148/O
12 Coated Universal O
M139/O,
M98/O
12 Clear
M139/O,
M98/O
12 Coated Universal O
M139/O,
M98/O
12 Clear
M139/O,
M98/O
12 Coated Universal O
M90/O,
M140/O
12 Clear
M90/O,
M140/O
12 Coated Universal O
M90/O,
M140/O
12 Clear
M90/O,
M140/O
12 Clear
Universal O
12000
4100
2850
88 3000
|
|
|
1,4,17,
30,48
12000
3800
2640
88 2900
1,4,17,
30,48
Universal O
16000
5900
4365
88 3000
1,4,17,
26,30,48
16000
5500
3900
88 3000
1,4,17,
26,30,48
Universal O
12000
6000
4800
93 4000
1,4,17,26,30,48
12000
5600
4480
93 3800
1,4,17,26,30,48
Universal O
16000
9000
6660
88 3000
1,4,17,27,
30,48
16000
8100
5994
88 3000
1,4,17,27,
30,48
Universal O
20000
8200
6150
93 4000
1,4,17,
27,30,48
Universal O
20000
7500
5625
90 4000
1,4,17,27,48
Symbols/Footnotes on page 101-102
040_HID_F_print.qxd
12/17/07
E17, E17/ED17
8:29 AM
Page 93
BT28, BT28/ED28, BT28/ET23.5
BT37
POWERBALL® CERAMIC METALARC® E17 & HIGH WATTAGE
High CRI, Pulse Start – Open or Enclosed Fixtures
4
Watts Bulb
Base
Product
Number Ordering Abbreviation
150
E26 Med
64741
E17
MCP150/U/MED/830PB
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
M102/O
12 Clear
Universal O
12000
13000
11000
88 3000
|
|
|
1,4,17,30,
31,48
64742
MCP150/C/U/MED/830PB
M102/O
12 Coated Universal O
12000
12000
10000
88 3000
1,4,17,30,
31,48
250
BT28
EX39 Excl
Mogul
64786
MCP250/PS/BU-ONLY/940PB
M153/O
6
Clear
BU ± 15° O
15000
24000
19200
94 4200
1,4,17,
23,48
64821
MCP250/C/PS/BU-ONLY/940PB
M153/O
6
Coated BU ± 15° O
15000
22500
18000
94 4000
1,4,17,23,
H
I
D
48
320
BT37
EX39 Excl
Mogul
64834
MCP320/PS/BU-ONLY/840PB
M154/O
6
Clear
BU ± 15° O
20000
37500
28125
88 4000
64851
MCP320/C/PS/BU-ONLY/840PB
M154/O
6
Coated BU ± 15° O
20000
36000
27000
88 3900
1,4,17,
48
1,4,17,
48
METALARC® PULSE START
High Output, Reduced Color Shift – Enclosed Fixtures
4
Watts Bulb
Base
175
E26 Med
64171
MS175/PS/BU-ONLY/MED
M152/E,
M137E
12 Clear
BU ± 15° E
15000
17500
12800
65 4000
4,18,23,39
64170
MS175/C/PS/BU-ONLY/MED
M152/E,
M137/E
12 Coated BU ± 15° E
15000
16600
12500
70 3700
4,18,23,39
64815
MS175/PS/BU-ONLY
M152/E,
M137/E
12 Clear
BU ± 15° E
15000
17500
12800
65 4000
4,18,23,39
64816
MS175/C/PS/BU-ONLY
M152/E,
M137/E
12 Coated BU ± 15° E
15000
16600
12500
70 3700
4,18,23,39
ED17
ED28
200
250
320
400
E39 Mogul
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Product
Number Ordering Abbreviation
ET23.5
E39 Mogul
64837
MS200/PS/BU-ONLY/ET23.5
M136/E
12 Clear
BU ± 15° E
15000
19000
13300
65 4200
4,18,23
BT28
E39 Mogul
64838
MS200/PS/BU-ONLY/BT28
M136/E
6
Clear
BU ± 15° E
15000
19000
13500
65 4000
4,18,23
64839
MS200/C/PS/BU-ONLY/BT28
M136/E
6
Coated BU ± 15° E
15000
18000
12800
70 3800
4,18,23
BT28
E39 Mogul
64320
M250/PS/U
M153/E,
M138/E
6
Clear
Universal E
15000V 22000V 15400V 65 3800
12000H 19000H 14000H
64578
MS250/PS/BU-ONLY
M153/E,
M138/E
6
Clear
BU ± 15° E
20000
23000
17000
65 4200
4,18,23
64617
MS250/C/PS/BU-ONLY
M153/E,
M138/E
6
Coated BU ± 15° E
20000
21500
15500
70 3600
4,18,23
64507
MS320/PS/BU-HOR
M154/E,
M132/E
6
Clear
BU-HOR
E
20000V 30000V 21000V 65 4300
15000H 28000H 19700H
4,18,23,41
64646
MS320/C/PS/BU-HOR
M154/E,
M132/E
6
Coated BU-HOR
E
20000V 30000V 19700V 70 3900
15000H 28000H 18400H
4,18,23,41
64188
M400/PS/U/BT28
M155/E
6
Clear
Universal E
20000V 36000V 25500V 65 4000
15000H 31000H 22400H
4,18,23,42
64191
MS400/PS/BD-ONLY/BT28
M155/E,
M135/E
6
Clear
BD ± 15° E
20000
40000
32500
65 4100
4,18,23,42,46
64189
MS400/PS/BU-ONLY/BT28
M155/E,
M135/E
6
Clear
BU ± 15° E
20000
40000
32500
65 4100
4,18,23,42,46
64321
M400/PS/U
M155/E
6
Clear
Universal E
20000V 36000V 25500V 65 4000
15000H 31000H 22400H
4,18,23
64525
MS400/PS/BU-ONLY
M155/S,
M135/S
6
Clear
BU ± 15° S
20000
4,6,20,21,23,24,
BT28
BT28
BT37
E39 Mogul
E39 Mogul
E39 Mogul
For more complete product information visit www.sylvania.com
42000
31000
65 4000
|
|
|
4,18,23
42,46
Symbols/Footnotes on page 101-102
93
040_HID_F_print.qxd
12/17/07
BT37
8:29 AM
E17
Page 94
BT28
METALARC® PULSE START
High Output, Reduced Color Shift – Enclosed Fixtures
4
H
I
D
Watts Bulb
Base
400
BT37
E39 Mogul
64527
MS400/C/PS/BU-ONLY
M155/S,
M135/S
6
Coated BU ± 15° S
20000
42000
29000
70 3600
750
BT37
E39 Mogul
65424
MS750/PS/BD-ONLY/BT37
M149/E
6
Clear
BD ± 15° E
16000
78000
67000
65 4000
64787
MS750/PS/BU-HOR/BT37
M149/E
6
Clear
BU-HOR
E
16000V 78000V 67000V 65 4000
12000H 68000H 56000H
4,18,33
64822
MS750/C/PS/BU-HOR/BT37
M149/E
6
Coated BU-HOR
E
16000V 75000V 63000V 70 3700
12000H 65000H 53000H
4,18,33
64351
M1000/PS/U/BT37
M141/E
6
Clear
Universal E
15000V 110000V 96000V 65 3800
9000H 107800H86300H
4,18
1000
BT37
E39 Mogul
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Product
Number Ordering Abbreviation
|
|
|
4,6,20,21,23,24,
42,46
4,18,33
METALARC PRO-TECH® PULSE START
High Output, Reduced Color Shift – Open or Enclosed Fixtures
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
50
E26 Med
64587
MP50/U/MED
M110/O
20 Clear
Universal O
20000V 3450
10000H
1900
70 3000
4,17
64588
MP50/C/U/MED
M110/O
20 Coated Universal O
20000V 3200
10000H
1820
70 2900
4,17
64625
MPD70/U/MED/840
M98/O
20 Clear
Universal O
7500H
6000V
5500
4000
80 4200
4,17
64621
MPD70/C/U/MED/840
M98/O
20 Coated Universal O
7500H
6000V
5100
3800
82 4000
4,17
64547
MP70/U/MED
M98/O
20 Clear
Universal O
15000V 5200
10000H
3400
75 3000
4,17
64546
MP70/C/U/MED
M98/O
20 Coated Universal O
15000V 4700
10000H
3100
75 2900
4,17
64417
MP100/U/MED
M90/O
20 Clear
Universal O
15000V 8500
10000H
5525
75 3000
4,17
64418
MP100/C/U/MED
M90/O
20 Coated Universal O
15000V 7900
10000H
5800
75 2900
4,17
64426
MPD100/U/MED/840
M90/O
20 Clear
Universal O
7500V
6000H
8400
5800
82 4200
4,17
64433
MPD100/C/U/MED/840
M90/O
20 Coated Universal O
7500V
6000H
7700
5500
82 4000
4,17
64402
MP150/U/MED
M102/O
20 Clear
Universal O
15000V 12900
10000H
8000
75 3000
4,17
64406
MP150/C/U/MED
M102/O
20 Coated Universal O
15000V 11600
10000H
7500
75 2900
4,17
64403
MPD150/U/MED/840
M102/O
20 Clear
Universal O
7500V
6000H
12500
11000
88 4200
4,17
64425
MPD150/C/U/MED/840
M102/O
20 Coated Universal O
7500V
6000H
11500
9500
88 4000
4,17
64790
MP250/C/PS/BU-ONLY
M153/O,
M138/O
6
Coated BU ± 15° O
15000
21000
16000
70 4000
4,17,23
64789
MP250/PS/BU-ONLY
M153/O,
M138/O
6
Clear
BU ± 15° O
15000
22500
17000
65 4000
4,17,23
64391
MP320/350/PS/BU-ONLY/BT28
M154/O,
M132/O,
M131/O
6
Clear
BU ± 15° O
20000
28600V 21000V 65 3800
33500H 24000H
3600
70
100
150
250
320
E17
E17
E17
E17
BT28
BT28
E26 Med
E26 Med
E26 Med
EX39 Excl
Mogul
EX39 Excl
Mogul
For more complete product information visit www.sylvania.com
94
|
|
|
4,17,23,41
Symbols/Footnotes on page 101-102
040_HID_F_print.qxd
12/17/07
BT28, BT37
8:29 AM
PAR38
Page 95
E17
BT28
METALARC PRO-TECH® PULSE START
High Output, Reduced Color Shift – Open or Enclosed Fixtures
4
Product
Number Ordering Abbreviation
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
320
BT28
EX39 Excl
Mogul
64349
MP320/350/C/PS/BU-ONLY/BT28
M154/O,
M132/O,
M131/O
6
Coated BU ± 15° O
20000
27700V 19000V 70 3600
32000H 22000H
4,17,23,41
350
BT37
EX39 Excl
Mogul
64769
MP350/400/PS/BU-ONLY
M131/O,
M155/O,
M135/O
6
Clear
BU ± 15° O
20000
33000V 24500V 65 3700
40000H 29500H
3500
4,17,23,42,46
64770
MP350/400/C/PS/BU-ONLY
M131/O,
M155/O,
M135/O
6
Coated BU ± 15° O
20000
32000V 23000V 70 3500
39000H 28000H
3300
4,17,23,42,46
|
|
|
H
I
D
METALARC PRO-TECH® PULSE START - PAR
5
Product
Number Ordering Abbreviation
ANSI
Code
Avg
Pkg Beam Beam Operating Fix Rated
Qty Type Angle Position Req Life(hrs) MBCP
Watts Bulb
Base
70
E26 Med Skt 64590
MP70PAR38/U/SP20/ECO
M98/O 6
SP
20°
Universal O
8500
18000
3400
75 3200
4,7,17,38
64592
MP70PAR38/U/FL35/ECO
M98/O 6
FL
35°
Universal O
8500
10000
3400
75 3200
4,7,17,38
64594
MP70PAR38/U/VWFL65/ECO
M98/O 6
VWFL 65°
Universal O
8500
3000
3400
75 3200
4,7,17,38
E26 Med Skt 64580
MP100PAR38/U/SP20/ECO
M90/O 6
SP
20°
Universal O
8500
26000
5800
75 3000
4,7,17,38
64582
MP100PAR38/U/FL35/ECO
M90/O 6
FL
35°
Universal O
8500
12000
5800
75 3000
4,7,17,38
64584
100
150
PAR38
PAR38
PAR38
MP100PAR38/U/VWFL65/ECO
M90/O 6
VWFL 65°
Universal O
8500
4500
5800
75 3000
4,7,17,38
E26 Med Skt 64593
MP150PAR38/U/SP20/ECO
M102/O 6
SP
20°
Universal O
8500
34000
8800
75 3200
4,7,17,38
64597
MP150PAR38/U/FL35/ECO
M102/O 6
FL
35°
Universal O
8500
17000
8800
75 3200
4,7,17,38
64599
MP150PAR38/U/VWFL65/ECO
M102/O 6
VWFL 65°
Universal O
8500
7500
8800
75 3200
4,7,17,38
®
METALARC PRO-TECH SUPERSAVER
|
|
|
Approx
Lumens
CCT Symbols &
(initial) CRI (K) Footnotes
®
Energy Saving, Metal Halide Retrofit - Open or Enclosed Fixtures
4
Watts Bulb
Base
360
EX39 Excl
Mogul
BT37
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Product
Number Ordering Abbreviation
ANSI
Code
64737
MSP360/SS/BU-ONLY
M59/O,
M165/O
6
Clear
BU ± 15° O
20000
35000
23500
65 4000
12,17,46
64738
MSP360/C/SS/BU-ONLY
M59/O,
M165/O
6
Coated BU ± 15° O
20000
34000
22500
70 3600
12,17,46
|
|
|
METALARC PRO-TECH®
Open or Enclosed Fixtures
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
175
ED17
E26 Med
64733
MP175/BU-ONLY/MED
M57/O
20 Clear
BU ± 15° O
10000
14400
10800
65 3600
17
BT28
EX39 Excl
Mogul
64773
MP175/BU-ONLY
M57/O
6
Clear
BU ± 15° O
10000
14400
10200
65 4000
17
64774
MP175/C/BU-ONLY
M57/O
6
Coated BU ± 15° O
10000
12800
7800
70 3800
17
64404
MP250/BU-ONLY
M58/O
6
Clear
BU ± 15° O
10000
23000
17000
65 4000
17
64405
MP250/C/BU-ONLY
M58/O
6
Coated BU ± 15° O
10000
20000
14350
70 3800
17
64705
MP400/BU-ONLY
M59/O
6
Clear
20000
40000
26000
65 3600
17
250
400
BT28
BT37
EX39 Excl
Mogul
EX39 Excl
Mogul
For more complete product information visit www.sylvania.com
BU ± 15° O
|
|
|
Symbols/Footnotes on page 101-102
95
040_HID_F_print.qxd
12/17/07
BT37
8:29 AM
BT56
Page 96
BT28
METALARC PRO-TECH®
Open or Enclosed Fixtures
4
Watts Bulb
Base
400
EX39 Excl
Mogul
1000
H
I
D
BT37
BT56
EX39 Excl
Mogul
Product
Number Ordering Abbreviation
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
64706
MP400/C/BU-ONLY
M59/O
6
Coated BU ± 15° O
20000
38500
25000
70 3400
17
64717
MP400/BD-ONLY
M59/O
6
Clear
BD ± 15° O
20000
40000
26000
65 3600
17
64714
MP1000/BU-ONLY
M47/O
6
Clear
BU ± 15° O
15000
109000 87500
65 3500
17
64716
MP1000/C/BU-ONLY
M47/O
6
Coated BU ± 15° O
15000
102000 82000
70 3200
17
|
|
|
METALARC® SUPER
High Output, Position Dedicated – Enclosed Fixtures
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
6
Watts Bulb
Base
Product
Number Ordering Abbreviation
175
BT28
E39 POM
64439
MS175/HOR
M57/E
64440
MS175/C/HOR
M57/E
6
Coated HOR ± 15° E
10000
14500
250
BT28
E39 POM
64448
MS250/HOR
M58/E
6
Clear
HOR ± 15° E
10000
23000
64449
MS250/C/HOR
M58/E
6
Coated HOR ± 15° E
10000
22000
64496
MS250/3K/HOR
M58/E
6
Coated HOR ± 15° E
10000
17200
64443
MS400/HOR/BT28
M59/E
6
Clear
HOR ± 15° E
20000
64444
MS400/C/HOR/BT28
M59/E
6
Coated HOR ± 15° E
20000
400
BT28
BT37
1000
E39 POM
E39 POM
Clear
HOR ± 15° E
10000
15000
8000
65 4200
11,18
8000
70 4000
11,18
15000
65 4200
11,18
14000
70 3800
11,18
13500
70 3200
11,18
39000
26000
65 4200
11,18
36500
24000
70 3800
11,18
64445
MS400/HOR
M59/E
6
Clear
HOR ± 15° E
20000
39000
25000
65 4200
11,18
64446
MS400/C/HOR
M59/E
6
Coated HOR ± 15° E
20000
38000
24000
70 3800
11,18
64498
MS400/3K/HOR
M59/E
6
Coated HOR ± 15° E
20000
33500
23300
70 3200
11,18
BT28
E39 Mogul
64441
MS400/BU-ONLY/BT28
M59/E
6
Clear
BU ± 15° E
20000
40000
26000
65 3800
18
BT37
E39 Mogul
64450
MS400/BU-ONLY
M59/S
6
Clear
BU ± 15° S
20000
42000
26000
65 4000
6,20,47
64452
MS400/C/BU-ONLY
M59/S
6
Coated BU ± 15° S
20000
42000
24700
70 3600
6,20,47
64454
MS400/3K/BU-ONLY
M59/S
6
Coated BU ± 15° S
20000
35000
22000
70 3200
20
64451
MS400/BD-ONLY
M59/S
6
Clear
BD ± 15° S
20000
42000
27500
65 4000
20
64435
MS1000/BU-ONLY
M47/S
6
Clear
BU ± 15° S
18000
115000 92000
65 4000
20
64460
MS1000/C/BU-ONLY
M47/S
6
Coated BU ± 15° S
18000
110000 88000
70 3400
20
64436
MS1000/BD-ONLY
M47/S
6
Clear
18000
115000 92000
65 4000
20
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
BT56
E39 Mogul
®
METALARC SUPERSAVER
BD ± 15° S
|
|
|
®
Energy Saving, Metal Halide Retrofit
4
Watts Bulb
Base
Product
Number Ordering Abbreviation
150
BT28
E39 Mogul
64719
M150/SS/U/BT28
M107/E,
M57/E
6
Clear
Universal E
10000V 13000V 7500V 65 4000
7500H 12000H 8500H
18,29,46
360
BT37
E39 Mogul
64655
MS360/SS/BU-HOR
M59/S,
M165/S
6
Clear
BU-HOR
S
20000V 36000V 23500V 65 4000
15000H 30000H 19000H
12,20,46
64656
MS360/C/SS/BU-HOR
M59/S,
M165/S
6
Coated BU-HOR
S
20000V 36000V 22500V 70 3600
15000H 30000H 19000H
12,20,46
64737
MSP360/SS/BU-ONLY
M59/O,
M165/O
6
Clear
20000
12,17,46
EX39 Excl
Mogul
For more complete product information visit www.sylvania.com
96
BU ± 15° O
35000
23500
65 4000
|
|
|
Symbols/Footnotes on page 101-102
040_HID_F_print.qxd
12/17/07
BT37
8:29 AM
Page 97
BT56
E17
BT28
ET18
METALARC® SUPERSAVER®
Energy Saving, Metal Halide Retrofit
4
Product
Number Ordering Abbreviation
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
360
BT37
EX39 Excl
Mogul
64738
MSP360/C/SS/BU-ONLY
M59/O,
M165/O
6
Coated BU ± 15° O
20000
950
BT56
E39 Mogul
64850
M950/SS/U/BT56
M47/E,
M176/E
6
Clear
18000V 103000V 80000V 65 4000
12000H 90000H 64000H
Universal E
34000
22500
70 3600
|
|
|
12,17,46
18,44
METALARC® STANDARD
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
175
E26 Med
64479
M175/U/MED
M57/E
20 Clear
Universal E
10000V 14400V 9300
7500H 12800H
65 4000
18
64480
M175/C/U/MED
M57/E
20 Coated Universal E
10000V 13000V 8400
7500H 11080H
70 3600
18
64471
M175/U
M57/E
6
Clear
Universal E
10000V 14400V 9300
7500H 12800H
65 4200
18
64472
M175/C/U
M57/E
6
Coated Universal E
10000V 14000V 8400
7500H 12000H
70 3800
18
Coated BU ± 15° E
10000
E17
BT28
250
400
64473
M175/3K/BU-ONLY
M57/E
6
70 3200
18
ET18
E39 Mogul
64474
M250/U/ET18
M58/E
10 Clear
Universal E
10000V 22000V 17500V 65 4000
7500H 20000H 13500H
18
BT28
E39 Mogul
64457
M250/U
M58/E
6
Clear
Universal E
10000V 22000V 15000V 65 4200
7500H 20000H 13000H
18
64458
M250/C/U
M58/E
6
Coated Universal E
10000V 21500V 17000V 70 3800
7500H 19500H 14000H
18
64475
M250/3K/BU-ONLY
M58/E
6
Coated BU ± 15° E
10000
70 3200
18
1500
11800
17500
7600
13000
ET18
E39 Mogul
64575
M400/U/ET18
M59/E
10 Clear
Universal E
20000V 36000V 25000V 65 4000
15000H 33000H 21500H
18
BT28
E39 Mogul
64488
M400/U/BT28
M59/E
6
Clear
Universal E
20000V 36000V 25000V 65 4000
15000H 32000H 20500H
18
64489
M400/C/U/BT28
M59/E
6
Coated Universal E
20000V 36000V 25000V 70 3600
15000H 32000H 20500H
18
64490
M400/U
M59/S
6
Clear
Universal S
20000V 36000V 23500V 65 4000
15000H 32000H 20500H
6,20,47
64492
M400/C/U
M59/S
6
Coated Universal S
20000V 36000V 22500V 70 3700
15000H 32000H 20500H
6,20,47
BT37
1000
E39 Mogul
E39 Mogul
BT37
E39 Mogul
64469
M1000/U/BT37
M47/E
6
Clear
Universal E
15000V 110000V 96000V 65 3800
9000H 107800H86300H
18
BT56
E39 Mogul
64468
M1000/U
M47/S
6
Clear
Universal S
18000V 110000V 86000V 65 4000
12000H 107800H86000H
20
64470
M1000/C/U
M47/S
6
Coated Universal S
18000V 107000V 80000V 70 3400
12000H 101600H80700H
20
64431
M1500/BU-HOR
M48/E
6
Clear
BU-HOR
E
3000
170000V 140000 70 4000
153000H
18,28
64432
M1500/BD
M48/E
6
Clear
BD ± 15° E
3000
167000 140000 70 4000
18
BT56
E39 Mogul
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 101-102
97
H
I
D
040_HID_F_print.qxd
BT37
12/17/07
8:29 AM
T (RSC base)
Page 98
R30/R40
T (G12 base)
ET23.5
E17
METALARC®SAFELINE®
Self-Extinguishing
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
400
E39 Mogul
64707
MT400/BU-ONLY
M59/S
6
Clear
BU ± 15° S
20000
36000
22000
60 4500
12,16,20,32
64709
MT400/C/BU-ONLY
M59/S
6
Coated BU ± 15° S
20000
35000
20600
65 4100
12,16,20,32
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
BT37
|
|
|
®
METALARC BRITELINE
Double-Ended – Enclosed Fixtures Only
4
H
I
D
Watts Bulb
Base
Product
Number Ordering Abbreviation
1500
T7
RX7s RSC
66619
M1500T7/DE
M_F
10 Clear
HOR ± 4° F
3000
150000 127500 65 4200
2,10,21,43,45,46
T8
Cer #8-10
Spade
66632
M1500T8/DE
M133/F
10 Clear
HOR ± 4° F
6000
150000 127500 65 4200
2,21,43,45
T8
RX7s RSC
66627
M2000T8/DE
M_F
10 Clear
HOR ± 4° F
3000
200000 170000 65 4000
2,10,21,43,45,46
T9
Cer #8-10
Spade
66631
M2000T9/DE
M134/F
10 Clear
HOR ± 4° F
3000
180000 153000 65 4200
2,21,43,45
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
2000
|
|
|
HQI® METAL HALIDE DOUBLE-ENDED
Compact, Quartz – Enclosed Fixtures
4
Watts Bulb
Base
Product
Number Ordering Abbreviation
70
T6
RX7s RSC
64360
HQI-DE70/WDX
M85/E
12 Clear
HOR ± 45° E
9000
5000
4400
76 3000
18,30
64362
HQI-DE70/NDX
M85/E
12 Clear
HOR ± 45° E
9000
5500
3800
83 4000
18,30
150
T7
RX7s RSC
64366
HQI-DE150/WDX
M81/E
12 Clear
HOR ± 45° E
12000
11000
9000
76 3000
18,30
64368
HQI-DE150/NDX
M81/E
12 Clear
HOR ± 45° E
12000
11250
9500
85 4200
18,30
|
|
|
®
HQI FIBER-OPTIC INTEGRATED DICHROIC REFLECTOR
Compact, High CRI, Quartz – Enclosed Fixtures
4
Watts Bulb
Base
150
2 Pin
Connector
R30
Product
Number Ordering Abbreviation
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
64339
M81/E
12 Clear
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
M81/E
12 Clear
HQI-R150/NDX/FO
HOR
E
9000
11000
|
|
|
85 4200
HQI® METAL HALIDE SINGLE-ENDED
4
Watts Bulb
Base
150
G12
T7.5
Product
Number Ordering Abbreviation
64342
HQI-SE 150/NDX
®
®
Universal E
9000
13000
9200
85 4200
|
|
|
18,30
®
LUMALUX PLUS AND LUMALUX PLUS ECO
Non-Cycling High Pressure Sodium
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
50
ET23.5
E39 Mogul
67607
LU50/PLUS/ECO
S68
20 Clear
Universal O
30000
4000
3600
22 1900
4,7,8
70
E17
E26 Medium
67322
LU70/PLUS/MED
S62
20 Clear
Universal O
30000
6300
5600
22 1900
4,8
ET23.5
E39 Mogul
67497
LU70/PLUS/ECO
S62
20 Clear
Universal O
30000
6300
5600
22 1900
4,7,8
For more complete product information visit www.sylvania.com
98
|
|
|
Symbols/Footnotes on page 101-102
040_HID_F_print.qxd
12/17/07
E17
8:29 AM
ET23.5, BT28
Page 99
ET18
E25
BT37
T (Mog base)
LUMALUX PLUS®AND LUMALUX PLUS® ECO®
Non-Cycling High Pressure Sodium
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
100
E17
E26 Medium
67323
LU100/PLUS/MED
S54
20 Clear
Universal O
30000
10000
9000
22 2100
4,8
ET23.5
E39 Mogul
67559
LU100/PLUS/ECO
S54
20 Clear
Universal O
30000
10000
9000
22 2100
4,7,8
150
ET23.5
E39 Mogul
67494
LU150/55/PLUS/ECO
S55
20 Clear
Universal O
30000
16000
14400
22 2100
|
|
|
4,7,8,13,
36
200
ET18
E39 Mogul
67495
LU200/PLUS/ECO
S66
20 Clear
Universal O
30000
22000
19800
22 2100
4,7,8
250
ET18
E39 Mogul
67572
LU250/PLUS/ECO
S50
20 Clear
Universal O
30000
29000
26100
22 2100
4,7,8
310
ET18
E39 Mogul
67660
LU310/PLUS/ECO
S67
20 Clear
Universal O
30000
37000
33300
22 2100
4,7,8
45000
22 2100
4,7,8
400
ET18
E39 Mogul
67312
LU400/PLUS/ECO
S51
20 Clear
Universal O
30000
50000
1000
E25
E39 Mogul
67316
LU1000/PLUS
S52
6
Universal O
30000
130000 124000 22 2100
®
®
Clear
H
I
D
4,8
®
LUMALUX STANDARD AND LUMALUX ECO
4
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
35
E17
E26 Medium
67500
LU35/MED
S76
20 Clear
67501
LU35/D/MED
S76
20 Coated Universal O
16000+
2100
50
E17
E26 Medium
67502
LU50/MED
S68
20 Clear
24000+
4000
67503
LU50/D/MED
S68
20 Coated Universal O
24000+
3700
ET23.5
E39 Mogul
67510
LU50/ECO
S68
20 Clear
24000+
4000
67511
LU50/D
S68
20 Coated Universal O
24000+
3700
3420
22 1900
4,22
E17
E26 Medium
67504
LU70/MED
S62
20 Clear
24000+
6300
5350
22 1900
4,22
67505
LU70/D/MED
S62
20 Coated Universal O
24000+
5800
4900
22 1900
4,22
ET23.5
E39 Mogul
67512
LU70/ECO
S62
20 Clear
24000+
6300
5500
22 1900
67513
LU70/D
S62
20 Coated Universal O
24000+
5500
4900
22 1900
4,22
E17
E26 Medium
67506
LU100/MED
S54
20 Clear
24000+
9500
8000
22 2100
4,22
67507
LU100/D/MED
S54
20 Coated Universal O
24000+
8800
7500
22 2100
4,22
ET23.5
E39 Mogul
67514
LU100/ECO
S54
20 Clear
24000+
9500
8000
22 2100
67515
LU100/D
S54
20 Coated Universal O
24000+
8800
7500
22 2100
4,22
E17
E26 Medium
67508
LU150/55/MED
S55
20 Clear
24000+
15800
13400
22 2100
4,13,22,36
67509
LU150/55/D/MED
S55
20 Coated Universal O
24000+
14500
12300
22 2100
4,13,22,36
ET23.5
E39 Mogul
67516
LU150/55/ECO
S55
20 Clear
24000+
16000
13800
22 2100
70
100
150
Universal O
Universal O
Universal O
Universal O
Universal O
Universal O
Universal O
Universal O
Universal O
16000+
2250
2050
22 1900
4,22
1935
22 1900
4,22
3600
21 1900
4,22
3420
22 1900
4,22
3600
22 1900
|
|
|
4,7,22
4,7,22
4,7,22
4,7,13,22,
36
67517
LU150/55/D
S55
20 Coated Universal O
24000+
14000
12500
22 2100
4,13,22,36
BT28
E39 Mogul
67518
LU150/100
S56
10 Clear
Universal O
24000+
15700
14100
22 2100
4,14,22,36
200
ET18
E39 Mogul
67576
LU200/ECO
S66
20 Clear
Universal O
24000+
22000
19800
22 2100
4,7,22
250
ET18
E39 Mogul
67578
LU250/ECO
S50
20 Clear
Universal O
24000+
29000
26100
22 2100
BT28
E39 Mogul
67521
LU250/D
S50
10 Coated Universal O
24000+
26000
23400
22 2100
310
ET18
E39 Mogul
67580
LU310/ECO
S67
20 Clear
Universal O
24000+
37000
32300
22 2100
4,7,22
400
ET18
E39 Mogul
67533
LU400/ECO
S51
20 Clear
Universal O
24000+
50000
45000
22 2100
4,7,22
BT37
E39 Mogul
67524
LU400/D
S51
10 Coated Universal O
24000+
47500
40000
22 2100
4,22
600
T14.5
E40 Mogul
67610
LU600 SUPER
S106
12 Clear
Universal O
24000
90000
81000
25 2200
3
4,7,22
4,22
750
BT37
E39 Mogul
67547
LU750
S111
6
Clear
Universal O
24000+
105000 94500
22 2100
3,22
1000
E25
E39 Mogul
67307
LU1000/ECO
S52
6
Clear
Universal O
24000+
130000 124000 22 2100
3,22
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 101-102
99
040_HID_F_print.qxd
ET23.5, ED28, BT28
12/17/07
ET18
8:30 AM
E25
Page 100
T (RSC base)
T (Mog base)
E17
PAR38
R30/R40
ED37
BT56
T (BY22D base
LUMALUX ®STANDBY
Dual Arc Tube,Long Life
4
H
I
D
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Watts Bulb
Base
Product
Number Ordering Abbreviation
70
ET23.5
E39 Mogul
67540
LU70/SBY
S62
20 Clear
Universal O
40000
6050
4950
22 1900
4,19
100
ET23.5
E39 Mogul
67542
LU100/SBY
S54
20 Clear
Universal O
40000
9500
7600
22 2100
4,19
150
ET23.5
E39 Mogul
67544
LU150/55/SBY
S55
20 Clear
Universal O
40000
15700
12100
22 2100
4,13,19,36
200
ET18
E39 Mogul
67586
LU200/100/SBY
S66
20 Clear
Universal O
40000
21500
18000
22 2100
4,19
250
ET18
E39 Mogul
67582
LU250/SBY
S50
20 Clear
Universal O
40000
27500
23200
22 2100
4,19
400
ET18
E39 Mogul
67584
LU400/SBY
S51
20 Clear
Universal O
40000
47500
40000
22 2100
4,19
1000
E25
E39 Mogul
67543
LU1000/SBY
S52
6
Universal O
24000+
127000 115000 22 2100
3,22
Product
Number Ordering Abbreviation
ANSI
Code
Avg
Pkg Lamp Operating Fix Rated
Approx Lumens
CCT Symbols &
Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
Clear
|
|
|
SPECIALTY
4
Watts Bulb
Base
400
T7
RX7s RSC
67527
LU400T7/RSC
S51
10 Clear
Horizontal E
24000
4600
41400
21 2100
4,18
T14.5
E40 Mogul
67711
400W PLANTASTAR
S51
12 Clear
Universal O
16000
55000
50000
22 2000
3,43
600
T14.5
E40 Mogul
67712
600W PLANTASTAR
S106
12 Clear
Universal O
16000
90000
81000
22 2000
3,43
1000
E25
E39 Mogul
67314
LU1000/PLANTASTAR
S52
6
Universal O
24000
130000 124000 22 2100
Clear
|
|
|
3
MERCURY VAPOR
9
Avg
Arc
Pkg Beam Beam Lamp Operating Fix Rated
Approx Lumens
CCT Length Symbols &
Qty Type Angle Finish Position Req Life (hrs) (initial) (mean) CRI (K) (in) Footnotes
Watts Bulb
Base
Product
ANSI
Number Ordering Abbreviation Code
75
E17
E26 Med
69402
H43AV-75/DX
H43
20
100
E17
E26 Med
69403
H38AV-100/DX
H38
20
PAR38
ADMed Skt 68843
H44GS-100SP
H44
12
SP
8°
E26 Med Skt 68846
H44GS-100/MDSKSP
H44
12
SP
8°
R40
E26 Med
69405
H38BP-100/DX
H38
10
FL
175
ET23.5
E39 Mogul
69408
H38JA-100/DX
H38
20
R40
E26 Med
69406
H39BP-175/DX
H39
10
ED28
E39 Mogul
69444
H39KB-175
H39
69445
H39KC-175/DX
H39
Coated Universal O
16000+ 2700
1800
45 4300
22,34
Coated Universal O
18000+ 4000
3560
45 4000
22,34
Universal O
16000
2500
1950
20 5900
22,34
Universal O
16000
2500
1950
20 5900
22,34
24000+ 2500
2000
45 4000
22,34
Coated Universal O
Coated Universal O
24000+ 4100
3300
45 4000
22,34
Coated Universal O
24000+ 5100
4100
45 4000
22,34
6
Clear Universal O
24000+ 7700
7150
22 5900
22,34
6
Coated Universal O
24000+ 8400
6800
45 4000
22,34
FL
250
ED28
E39 Mogul
69448
H37KC-250/DX
H37
6
Coated Universal O
24000+ 12500
10000 45 4000
22,34
400
ED37
E39 Mogul
69449
H33CD-400
H33
6
Clear Universal O
24000+ 20000
18700 22 5900
22,34
69450
H33GL-400/DX
H33
6
Coated Universal O
24000+ 23000
16200 43 4000
22,34
1000
BT56
E39 Mogul
69331
H36GW-1000/DX
H36
6
Coated Universal O
24000+ 58000
48500 45 4000
9,22,34
|
|
|
LOW PRESSURE SODIUM
9
Avg
Arc
Pkg Beam Beam Lamp Operating Fix Rated
Approx Lumens
CCT Length Symbols &
Qty Type Angle Finish Position Req Life (hrs) (initial) (mean) CRI (K) (in) Footnotes
Watts Bulb
Base
Product
ANSI
Number Ordering Abbreviation Code
18
T17
BY22D
69510
SOX18
L69
12
Clear BU+/-
E
18000
1800
1620
1700
35
T17
BY22D
69511
SOX35
L70
12
Clear BU+/-
E
18000
4550
4095
1700
55
T17
BY22D
69512
SOX55
L71
12
Clear BU+/-
E
18000
7800
7800
1700
90
T21
BY22D
69513
SOX90
L72
12
Clear HOR+/-
E
18000
14300
12155
1700
135
T21
BY22D
69514
SOX135
L73
12
Clear HOR+/-
E
18000
22600
19210
1700
180
T21
BY22D
69519
SOX180 6PK
L74RF
6
Clear HOR+/-
E
18000
32000
22400
1700
For more complete product information visit www.sylvania.com
100
|
|
|
Symbols/Footnotes on page 101-102
040_HID_F_print.qxd
12/17/07
8:30 AM
Page 101
SYMBOLS & FOOTNOTES FOR HIGH INTENSITY DISCHARGE (HID) LAMPS
Symbol
Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
New item introduced within the past year.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
This lamp is a High Color Rendering Lamp
Footnote
Description
1
Consult your OSRAM SYLVANIA Lighting Representative for compatible electronic operating systems.
2
Use in equipment where gasket material is protected from all lamp radiation.
3
Use with 5000V pulse rated sockets only.
4
Use with 4000V pulse rated sockets only.
5
Unjacketed reprographical/photochemical lamp.
6
20,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 120 hrs/start.
7
Passes Federal TCLP test based on NEMA LL Series Standards. TCLP data available upon request. Disposal regulations may vary depending
on location. Please check your local and state/provincial regulations.
8
Voltage rise due to fixture effect is to be evaluated using standard lamp types and not LUMALUX PLUS lamp types
9
H34 and H36 lamps are not interchangeable.
10
Consult your OSRAM SYLVANIA Lighting Representative for lamp/ballast compatibility.
11
Horizontally oriented lamps require a position oriented mogul (POM) socket to accept position oriented mogul bases.
12
Operates at 360 watts on 400w M59 ballast or a M165 ballast.
13
55 Volt lamp.
14
100 Volt lamp.
15
UNALUX lamps must be operated on mercury lag or reactor ballasts only.
16
Lamps must be operated on CW/CWA ballasts only
17
O = Lamps classified as O-type, comply with ANSI standard C78.389 for containment testing and may be used in open luminaries. See lamp
warning.
18
E = Lamps classified as E-type are to be used ONLY in suitably enclosed luminaries. See lamp warning.
19
Standby feature not guaranteed beyond 24,000 operating hours.
20
S = When operated within 15 degrees of vertical, this lamp may be operated in an open luminaire provided the installation is not near people
or flammable or combustible material, otherwise it must be operated in a suitably enclosed luminaire. See lamp warning.
21
F = Enclosed luminaire with UV filter and lens interlock required. WARNING: This lamp emits ultraviolet radiation which can cause serious
skin burn and eye inflammation. Additionally, this lamp operates under high pressure at very high temperatures. Should the lamp break there
can exist a danger of personal injury and/or fire from the broken lamp particles being discharged. This lamp should only be used in fully
enclosed luminaire with ultraviolet (UV) filter tempered glass lens capable of containing any particles discharges by breakage. Do not use this
lamp if the filter lens is damaged or missing. This lamp should only be used in luminaires equipped with safety interlock lens switches. See
lamp warning.
22
Mean lumens measured at 50% of average rated life
23
When operated on ballasts having a sustaining voltage less than 270V, lamp life may be significantly reduced.
24
The circuit must include overcurrent protection (I.e. Thermally switched ballast).
25
Lamp requires a nominal Open Circuit Voltage of 230V or higher. Without an igniter in the circuit minimum OCV is 209Vrms.
26
Lamps may be operated on ANSI M98 Compliant Ballast.
27
Lamps may be operated on ANSI M140 Compliant Ballast.
28
Published rated life based on 5 hours per start. Life rating will increase to 6,000 hours if operated for at least 10 hours per start in the base
up position. Lumens will be lower for operating positions other than base up. See lumen tilt factor curve in the Metal Halide Specification
Guide.
29
Operates at 150W on a 175W M57 ballast or a M107 ballast.
30
UV-Stop quartz
31
Lamps may be operated on a M142 Compliant ballast.
H
I
D
For more complete product information visit www.sylvania.com
101
040_HID_F_print.qxd
12/17/07
8:30 AM
Page 102
SYMBOLS & FOOTNOTES FOR HIGH INTENSITY DISCHARGE (HID) LAMPS
H
I
D
Footnote
Description
32
Do not operate on dimming systems. Dimming systems will prevent a lamp the ability to self-extinguish.
33
When operating on a ballast with a sustaining voltage less than 310V, lamp life may be significantly reduced.
34
In general, Horizontal lumen values will be 5-10% lower than the vertical lumen values.
35
Lamps may be operated on ANSI M85 or M98 Compliant ballasts.
36
LU150/100 and LU150/55 lamps are not interchangeable.
37
Lamps may be operated on ANSI M142 or M81 Compliant ballasts.
38
Lamps with a E26 medium skirt base are not compatible with exclusionary medium sockets.
39
Lamps may be operated on ANSI M137 Compliant ballasts.
40
The ULX880 lamp should not be used on any circuit other than 480V H36 mercury reactor.
41
Lamps may be operated on ANSI M132 (320W) Compliant ballasts.
42
Lamps may be operated on ANSI M135 (400W) Compliant ballasts.
43
Use with 4-5kV igniter.
44
Operates at 950 watts on 1000W M47 CWA ballasts
45
For use where seal temperature does not exceed 350C.
46
Please consult with your ballast and fixture manufacturer for compatible systems
47
Lamps may be operated M155 or M135 pulse start ballast with a sustaining voltage greater than 270V
48
The emergence of electronic ballasts to operate metal halide lamps has produced additional need to separate the lamp designation of quartz
and ceramic metal halide lamps, as there can be some important differences in system performance. Therefore the C lamp designation from
NEMA has been introduced going forward for future differentiation of ceramic metal halide lamps and they will begin to be labeled
accordingly.
For more complete product information visit www.sylvania.com
102
100_cref.qxd
12/17/07
8:27 AM
Page 103
Manufacturers’ Cross Reference
HIGH INTENSITY DISCHARGE LAMPS
SYLVANIA
GE
PHILIPS
METALARC CERAMIC METAL HALIDE
MC150T7.5/U/G12/940 PB
MC70T6/U/G12/940 PB
MC150T7.5/G12/U/830 PB
MC39T6/U/G12/830 PB
MCP70/U/MED/830 PB
MCP70/C/U/MED/830 PB
MCP100/U/MED/830 PB
MCP100/C/U/MED/830 PB
MCP70PAR38/U/SP/830/ECO PB
MCP70PAR38/U/FL/830/ECO PB
MCP70PAR38/U/VWFL/830/ECO PB
MCP100PAR38/U/SP/830/ECO PB
MCP100PAR38/U/FL/830/ECO PB
MCP100PAR38/U/VWFL/830/ECO PB
MC39TC/U/G8.5/830 PB
MC70T6/DE/830 PB
MC150T7.5/DE/830 PB
MCP320/PS/BU-ONLY/840/BT37 PB
MCP70/U/MED/940 PB
MCP70/C/U/MED/940 PB
MC70T6/U/G12/930 PB
MCP70PAR30LN/U/930/SP/ECO PB 90V
MCP70PAR30LN/U/930/FL/ECO PB 90V
MCP100/U/MED/940 PB
MC39T6/U/G12/940 PB 90V
MCP150/U/MED/830 PB
MCP150/C/U/MED/830 PB
MCP250/PS/BU-ONLY/940 PB
MCP250/C/PS/BU-ONLY/940 PB
MCP39PAR20U830SP PB
MC70TC/U/G8.5/930 PB
MCP39PAR20U830FL PB
MCP50/U/MED/830 PB
MCP150/PAR38/U/830/SP/ECO PB
MCP150/PAR38/U/830/FL/ECO PB
MCP150/PAR38/U/830/VWFL/ECO PB
MCP50/C/U/MED/830 PB
MCP320/C/PS/BU-ONLY/840/BT37 PB
MCP20PAR30LN/U/830/FL/ECO PB
MCP20PAR30LN/U/830/SP/ECO PB
MCP39PAR30LNU830SPECO PB
MCP39PAR30LNU830FLECO PB
MC20TC/U/G8.5/830PB
MC70TC/U/G8.5/930PB
CMH150/T/U/942/G12
CMH70/T/U/942/G12
CMH150/T/U/830/G12
CMH39/T/U/830/G12
CMH70/U/830MED
CMH70/C/U/830/MED
CMH100/U/830/MED
CMH100/C/U/830/MED
CMH70/PAR38/830/SP15
CMH70PAR38/830FL25
CMH70/PAR38/830WF
CMH100/PAR38/830S15
CMH100/PAR38/830/FL2
CMH100/PAR38/830W
CMH39/TC/U/830/G8.5
CMH70/TD/942/RX7S
CMH150/TD830/RX7S
CMH320/PA/O
CMH70/U/942/MED/O
CMH70/C/U/942/MED/O
---CMH70/PAR30L/830SP
CMH70/PAR30L/830FL
---CMH39/T/U/942/G12
CMH150/U/830/MED/O
CMH150/C/U/830/MED/O
CMH250/VBU/PA/O
CMH250/C/VBU/PA/O
CMH39/UPAR20/SP10
CMH70/TC/U/942/G8.5
CMH39/UPAR20/FL25
---------------CMH320/C/PA/O
CMH20PAR30/FL25
CMH20PAR30/SP10
CMH39/PAR30L/SP10
CMH39/PAR30L/FL25
CMH20/TC/U/830/G8.5
CMH70/T/U/830/G12
CDM150/T6/942
CDM70/T6/942
CDM150/T6/830
CDM35/T6/830
MHC70/U/MP/3K
MHC70/C/U/MP/3K
MHC100/U/MP/3KALTO
MHC100/C/U/MP/3KALTO
CDM70/PAR38/SP/3K
CDM70/PAR38/FL/3K
CDM70/PAR38/WFL/3K
CDM100/PAR38/SP/3K
CDM100/PAR38/FL/3K
CDM100/PARWFL/3K
CDM35/TC/830
CDM70/TD/830
CDM150/TD/830
CDM320/V/O/PS/4K/ALTO
MHC70/U/MP/4K/ALTO
MHC70/C/U/MP/4K/ALTO
---CDM70/PAR30L/M/SP (830)
CDM70/PAR30L/M/FL (830)
MHC100/U/MP/4K/ALTO
---MHC150/U/MP/3K/ALTO
MHC150/C/U/MP/3K/ALTO
------CDM35/PAR20/M/SP
CDM70/TC/830
CDM35/PAR20/M/FL
MHC50/U/MP/3K/ALTO
------------CDM320/C/V/O/PS/4K/ALTO
------CDM35/PAR30L/M/SP
CDM35/PAR30L/M/FL
---CDM70/T6/830
MXR50/U/MED
MXR50/U/MED/O
MVR70/C/U/MED
MVR70/U/MED
MXR100/C/U/MED
MXR100/U/MED
MXR150/C/U/MED/O
MXR150/U/MED/O
MVR175/C/VBU/PA
MVR175/C/VBU/MED/PA
MVR175/VBU/PA
MVR175/VBU/VBU/PA
------------MVR250/C/VBU/PA
MVR250/VBU/PA
MVR250/C/VBU/MED/PA
------------------------------MS175/BU/PS
-------------------------
H
I
D
METALARC PULSE START
MP50/C/U/MED
MP50/U/MED
MP70/C/U/MED
MP70/U/MED
MP100/C/U/MED
MP100/U/MED
MP150/C/U/MED
MP150/U/MED
MS175/C/PS/BU-ONLY
MS175/C/PS/BU-ONLY/MED
MS175/PS/BU-ONLY
MS175/PS/BU-ONLY/MED
MS200/C/PS/BU-ONLY/BT28
MS200/PS/BU-ONLY/BT28
MS200/PS/BU-ONLY/ET23.5
M250/PS/U
MP250/C/PS/BU-ONLY
MP250/PS/BU-ONLY
MS250/C/PS/BU-ONLY
For more complete product information visit www.sylvania.com
103
100_cref.qxd
12/17/07
8:27 AM
Page 104
Manufacturers’ Cross Reference Guide (continued)
HIGH INTENSITY DISCHARGE LAMPS - METALARC CERAMIC
H
I
D
SYLVANIA
GE
PHILIPS
MS250/PS/BU-ONLY
MS320/C/PS/BU-HOR
MS320/PS/BU-HOR
MP320/350/C/PS/BU-ONLY/BT28
MP320/350/C/PS/BU-ONLY/BT28
MP320/350/PS/BU-ONLY/BT28
MP320/350/PS/BU-ONLY/BT28
MP350/400/C/PS/BU-ONLY
MP350/400/PS/BU-ONLY
MS400/C/PS/BU-ONLY
MS400/PS/BD-ONLY/BT28
MS400/PS/BU-ONLY
MS400/PS/BU-ONLY/BT28
MS750/C/PS/BU-HOR/BT37
MS750/PS/BD-ONLY/BT37
MS750/PS/BU-HOR/BT37
M1000/PS/U/BT37
MVR250/VBU/PA
MVR320/C/VBU/XHOPA
MVR320VBU/XHO/PA
MPR350/C/VBU/PA
MPR320/C/VBU/XHO/PA
MPR350/VBU/PA
MPR320/VBU/XHOPA
MPR400/C/VBU/XHOPA
MPR350/VBU/PA
MVR400/VBU/XHO/PA
MVR400/C/VBU/ED28/PA
MVR400/VBU/HO/PA
MVR400/VBU/ED28/PA
------MVR750/VBU/PA
MVR1000/U/BT37/PA
---------MP350/C/BU/PS
MP320/C/BU/PS
MP350/BU/PS
MP320/BU/PS
MP400/C/BU/PS
MP400/BU/PS
MS400/C/BU/PS
---MS400/BU/PS
------------MS1000/BU/BT37/PS
MVR150/U/WM
MVR360CVBU/WM/HO
MVR360/VBU/WM/HO
MVR360/C/VBU/WM/HO
MPR360/VBU/WM/HO/O
----
------MS360/BU/EW
MP360/C/BU/EW
MP360BU/EW
----
MVR175/HOR
MVR175/C/HOR
---MVR250/C/HOR
MVR250/HOR
MVR400/VBU/XHO
MVR400/VBD
MVR400VBU/HO
MVR400/VBU/BT28
MVR400/C/VBU
MVR400/C/HOR/MOG
---MVR400/HOR/MOG
MVR400/HOR/BT28
---MVR1000/VBU/HO
MVR1000/C/VBU/HO
---MS175/C/HOR
---MS250/C/HOR
---MS400/3K/BU
---MS400/BU
MS400/BU/ED28
MS400/C/BU
------------MS1000/BD
MS1000/BU
MS1000/C/BU
METALARC SUPERSAVER
M150/SS/U/BT-28
MS360/C/SS/BU-HOR
MS360/SS/BU-HOR
MSP360/C/SS/BU-ONLY
MSP360/SS/BU-ONLY
M950/SS/U/BT56
METALARC SUPER
MS175/HOR
MS175/C/HOR
MS250/3K/HOR
MS250/C/HOR
MS250/HOR
MS400/3K/BU-ONLY
MS400/BD-ONLY
MS400/BU-ONLY
MS400/BU-ONLY/BT28
MS400/C/BU-ONLY
MS400/C/HOR
MS400/C/HOR/BT28
MS400/HOR
MS400/HOR/BT28
MS1000/BD-ONLY
MS1000/BU-ONLY
MS1000/C/BU-ONLY
METALARC STANDARD® & METALARC PRO-TECH®
M175/U
M175/C/U
M175/C/U/MED
M175/U/MED
M175/3K/BU-ONLY
MP175/BU-ONLY
MP175/BU-ONLY/MED
MP175/C/BU-ONLY
M250/U
M250/C/U
M250/3K/BU-ONLY
M250/U/ET18
MP250/BU-ONLY
MP250/C/BU-ONLY
M400/U
M400/C/U
M400/C/U/BT28
M400/U/BT28
M400/U/ET18
MVR175/U
MVR175/C/U
MVR175/C/U/MED
MVR175/U/MED
MVR175/SP30/U
MPR175/VBU/O
---MPR175/C/VBU/O
MVR250/U
MVR250/C/U
MVR250/SP30/U
---MPR250/VBU/O
MPR250/C/VBU/O
MVR400/U
MVR400/C/U
MVR400/C/U/ED28
MVR400/U/ED28
----
For more complete product information visit www.sylvania.com
104
MH175/U
MH175/C/U
MH175/C/U/M
MH175/U/M
MH175/3K/BU
MP175/BU
------MH250/U
MH250/C/U
MH250/3K/BU
---MP250/BU
---MH400U
MH400/C/U
MH400/U/ED28
MH400/U/ED28
----
100_cref.qxd
12/17/07
8:27 AM
Page 105
Manufacturers’ Cross Reference (continued)
HIGH INTENSITY DISCHARGE LAMPS - METAL HALIDE / HIGH PRESSURE SODIUM
SYLVANIA
GE
®
PHILIPS
®
METALARC STANDARD & METALARC PRO-TECH
MP400/BD-ONLY
MP400/BU-ONLY
MP400/C/BU-ONLY
M1000/U
M1000/C/U
M1000/U/BT37
MP1000/BU-ONLY
MP1000/C/BU-ONLY
M1500/BD
M1500/BU-HOR
---MPR400/VBU/HO/O
MPR400/C/VBU/HO/O
MVR1000/U
MVR1000/C/U
MVR1000/U/BT37
MPR1000/VBU/O
------MVR1500/HBU
---MP400/BU
MP400/C/BU
MH1000/U
MH1000/C/U
MH1000/U/BT37
MP1000/BU
---MH1500/U
MH1500/U
SPL1500/L/H/652
---MQI2000/T9/40
----------
MVT400/VBU
MVT400/C/VBU
MHT400/U
MHT400/C/U
ARC150/TD/UVC/742
ARC150/TD/UVC/730
ARC70/TD/UVC/743
ARC70/TD/UVC/730
ARC150T/U/840G12
MHN150/TD/840
---MHN70/TD/840
-------
H
I
D
METALARC BRITELINE
M1500T7/DE
M2000T8/DE
M2000T9/DE
METALARC SAFELINE
MT400/BU-ONLY
MT400/C/BU-ONLY
DOUBLE-ENDED HQI
HQI-DE150/NDX
HQI-DE150/WDX
HQI-DE70/NDX
HQI-DE70/WDX
HQI-SE 150/NDX
LUMALUX PLUS® ECOLOGIC®
LU50/PLUS/ECO
LU70/PLUS/ECO
LU70/PLUS/MED
LU100/PLUS/ECO
LU150/55/PLUS/ECO
LU200/PLUS/ECO
LU250/PLUS/ECO
LU310/PLUS/ECO
LU400/PLUS/ECO
LU70/ECO/NC
---LU100/ECO/NC
LU150/ECO/NC
LU200/ECO/NC
LU250/ECO/NC
---LU400/ECO/NC
C50S68/ALTONC
C70S62/ALTO/PLUS
---C100S54/ALTONC
C150S55/ALTONC
C200S66/ALTONC
C250S50/ALTO/NC
---CS400S51/ALTO/PLUS
LUMALUX® STANDARD & ECOLOGIC®
LU35/D/MED
LU35/MED
LU50/D/MED
LU50/ECO
LU50/MED
LU50/D
LU70/D
LU70/D/MED
LU70/ECO
LU70/MED
LU100/D
LU100/D/MED
LU100/ECO
LU100/MED
LU150/100
LU150/55/D
LU150/55/D/MED
LU150/55/ECO
LU150/55/MED
LU200/ECO
LU250/D
LU250/ECO
LU310/ECO
LU400/D
LU35/D/MED
LU35/MED
LU50/D/MED
LU50
LU50/MED
LU50/D
LU70/D
LU70/D/MED
LU70/ECO
LU70/MED
LU100/D
LU100/D/MED
LU100/ECO
LU100MED
LU150/100
LU150/55/D
LU150/D/MED
LU150/55/ECO
LU150/MED
LU200/ECO
LU250/D
LU250/ECO
LU310
LU400/D
C35S76/D/M
C35S76/M
C50S68/D/M
C50S68/ALTO
C50S68/M
C50S68/D/ALTO
C70S62/D/ALTO
C70S62/D/M
C70S62/ALTO
C70S62/M
C100S54/D/ALTO
C100S54/D/M
C100S54/ALTO
C100S54/M
C150/S56/ALTO
C50S55/D/ALTO
C150S55/D/M
C150S55/ALTO
C150S55/M
C200S66/ALTO
C250S50/D/ALTO
C250S50/ALTO
C310S67
C400S51/D/ALTO
For more complete product information visit www.sylvania.com
105
100_cref.qxd
12/17/07
8:27 AM
Page 106
Manufacturers’ Cross Reference Guide (continued)
HIGH INTENSITY DISCHARGE LAMPS - HIGH PRESSURE SODIUM / SOX / MERCURY VAPOR
SYLVANIA
GE
®
PHILIPS
®
LUMALUX STANDARD & ECOLOGIC
LU400/ECO
LU750
LU1000
LU400/ECO
LU750
LU1000/ECO
C50S68/D/ALTO
---C1000S52/ALTO
LU70/SBY/XL
LU100/SBY/XL
LU150/55/SBY/XL
LU200/SBY/XL
LU250/SBY/XL
LU400/SBY/XL
LU1000/SBY/XL
C70S62/2
C100S54/2
C150S55/2
---C250S50/2
C400S51/2
C1000S52/2
LUMALUX STANDBY
H
I
D
LU70/SBY
LU100/SBY
LU150/55/SBY
LU200/100/SBY
LU250/SBY
LU400/SBY
LU1000/SBY
SOX LOW PRESSURE SODIUM
SOX18
SOX35
SOX55
SOX90
SOX180
SOX18
SOX35
SOX55
SOX90
----
SOX-E18
SOX35
SOX55
SOX90
SOX180
HR400A33
HR400DX33
HR1000DX36
HR250DX37
HR100DX38/MED
HR100RFL38
HR100DX38/12PK
HR175RFL39
HR175A39/CP
HR175DX39
HR75DX43
HR100PSP44/MED
HR100PSP44
H33CD-400
H33GL-400/DX
H36GW-1000/DX
H37KC-250/DX
H38MP-100/DX
H38BP-100/DX
H38JA-100/DX
H39BM-175
H39KB-175
H39KC-175/DX
H43AV-75/DX
H44GS-100/M
H44GS-100
MERCURY VAPOR
H33CD-400
H33GL-400/DX
H36GW-1000/DX
H37KC-250/DX
H38AV-100/DX
H38BP-100/DX
H38JA-100/DX
H39BP-175/DX
H39KB-175
H39KC-175/DX
H43AV-75/DX
H44GS-100/MDSKSP
H44GS-100SP
For more complete product information visit www.sylvania.com
106
050_CFL_drop.qxd
12/12/07
3:50 PM
Page 107
OSRAM SYLVANIA: THE LEADER IN
ENERGY SAVING COMPACT FLUORESCENT LAMPS
The compact fluorescent lamp is an electric discharge device which utilizes a low pressure mercury vapor arc to generate
ultra-violet (plus a little visible) energy. The ultra-violet energy is absorbed by a phosphor coat on the inside of the glass tube
and converted by the phosphor to visible wavelengths; the wavelengths of the light generated are determined by the
composition of the phosphor. In addition to the small amount of mercury vapor, the fluorescent tube contains an
atmosphere of an inert gas, usually argon, krypton, neon, or a mixture of two or more of these gases. The pressure
of the gases contained in the lamp is very low, usually from 2 to 3 torr. Atmospheric pressure is 760 torr.
BULB
PHOSPHOR
CATHODE
EXHAUST TUBE
A wide variety of compact
fluorescent bulb shapes
are available
Coating inside the bulb
transforms ultraviolet radiation
into visible light. Color of light
produced depends on
composition of phosphor.
“Hot cathodes” at each end of
lamp are coated with emissive
materials which emit electrons.
Usually made of coiled-coil or
single-coil tungsten wire.
Air is exhausted through this
tube during manufacture and
inert gas introduced into the
bulb.
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
MERCURY
GAS
STEM PRESS
LEAD-IN WIRES
BASE
A minute quantity of
liquid mercury is placed
in the bulb to furnish
mercury vapor.
Usually a mixture of
argon and neon at low
pressure.
The lead-in wires have an
air tight seal here and are
made of specific material
to assure about the same
coefficient of expansion
as the glass.
Connect to the base pins
and carry the current to
and from the cathodes
and the mercury arc.
Several different types
used to connect the lamp
to the electric circuit and
to support the lamp in
the lampholder.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 124
107
050_CFL_drop.qxd
12/12/07
3:50 PM
Page 108
HOW TO READ PRODUCT INFORMATION - COMPACT FLUORESCENT
Avg
Nominal
MOL
Wattage Bulb (in)
(mm) Base
Product
NEMA Generic
Number Ordering Abbreviation Designation
Pkg
Qty
Avg
Rated
CCT
Life (hrs) (K)
13
29116
6
8000
Twist 4.6
117
Med
CF13EL/MINITWIST
Approx Lumens
Initial
Mean
CRI @25°C/77°F
(@35˚C/95˚F)
3000 82
800
Symbols &
Footnotes
640
|
|
|
|
2,21,28,
36,63,64
26
D(T4) 6.8
173
G24D-3
20710
CF26DD/830/ECO
CFQ26W/G24D/30
50
10000
3000 82
1800
1548
2,21,28,
34,37
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
32
T(T4) 5.5
140
GX24Q-3 20885
CF32DT/E/IN/835/ECO CFTR32W/GX24Q/35 50
10000
3500 82
2328
2400
2002
2064
2,21,28,
33,35,59
40
L(T5) 22.6
573
2G11
FT40DL/841/RS/ECO FT40W/2G11/RS/41
20000
4100 82
3150
2709
2,21,28
Nominal Wattage
Bulb
Base
MOL
Symbols & Footnotes
Ordering Abbreviation
NEMA Generic
Designation
CCT
CRI
Initial & Mean Lumens
20586
10
Design wattage on reference ballast. Actual wattage dependent on ballast.
Describes the shape of the bulb.
Base designations for compact fluorescent lamps are the NEMA designations. Please see page 111 for base illustrations.
Maximum overall length. The actual length of the lamp measured from the bottom of the base to the top outside edge of the
glass. In many cases, the bottom of the base is the bottom of the center post of the base of the lamp.
Most symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and
footnotes are at the end of the fluorescent section.
A text description of the lamp. Please see below for several examples and explanations of some of the codes.
Designation assigned by NEMA (National Electrical Manufacturers Association).
Correlated Color Temperature. The degree of “whiteness” of the light. Expressed in kelvins (K).
Please see page 109 for more information.
Color Rendering Index. A numbering system for rating the relative color rendering quality of a light source compared to
a standard. Please see page 109 for more information.
Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at
40% of the rated life of the lamp. Compact Fluorescent lamp lumens are measured at 25°C (77°F) and 35˚C (95˚F)
How to Read Ordering Abbreviations
CF26DD/830
CF
Compact Fluorescent
26
Nominal lamp wattage
DD
DULUX® Double
8
82 CRI
30
3000K CCT
CF32DT/E/IN/835/ECO
CF
Compact Fluorescent
32
Nominal lamp wattage
DT
DULUX Triple
E
Electronic or dimming
operation
IN
Amalgam
8
82 CRI
35
3500K CCT
ECO ECOLOGIC
FT40DL/841/RS/ECO
FT
Fluorescent Twin
40
Nominal lamp wattage
DL
DULUX Long
8
82 CRI
41
4100K CCT
RS
Rapid Start
ECO ECOLOGIC
CF20EL/830/MED/ECO
CF
Compact Fluorescent
20
Nominal lamp wattage
EL
Electronic Lamp
8
82 CRI
30
3000K CCT
MED Medium screw base
ECO ECOLOGIC
DULUX® LAMP FAMILIES
CF... DS = DULUX Single, 2-pin for magnetic operation, ECOLOGIC®
CF... DS/E = DULUX Single, 4-pin for electronic or dimming operation
CF... DD = DULUX Double, 2-pin for magnetic operation, ECOLOGIC
CF... DD/E = DULUX Double, 4-pin for electronic or dimming operation, ECOLOGIC
CF... DT = DULUX Triple, 2-pin for magnetic operation, ECOLOGIC
CF... DT/E = DULUX Triple, 4-pin for electronic or dimming operation, ECOLOGIC
CF... DT/E/IN = DULUX Triple, 4-pin for electronic or dimming operation, amalgam, ECOLOGIC
FT... DL = Fluorescent Twin, DULUX Long, 4-pin
CF... DF = DULUX Flat, 4-pin
CF... EL = DULUX self-ballasted, medium screw base
For more complete product information visit www.sylvania.com
108
Symbols/Footnotes on page 124
050_CFL_drop.qxd
12/12/07
3:50 PM
Page 109
For weight and measurement information, please visit www.sylvania.com
Lamp Disposal Labeling
The following information appears on packages of fluorescent lamps. For more information on lamp disposal labeling, see the inside
back cover of this catalog.
Hg
C
O
M
P
A
C
T
Lamp Contains Mercury
Manage in accordance with disposal laws
See www.lamprecycle.org or 1-866-666-6850
F
L
U
O
R
E
S
C
E
N
T
COMPACT FLUORESCENT LAMP COLORS
COLOR
COLOR
ABBREVIATION
CORRELATED
COLOR
TEMPERATURE(1)
COLOR
RENDERING
INDEX(2)
DULUX® 2700K
SOFT WHITE
WARM WHITE
DULUX SOFT WHITE
DULUX 3000K
DULUX 4100K
DULUX 5000K
DAYLIGHT™
827
Soft White
WW
830
830
841
850
D
2700
2900
3000
3000
3000
4100
5000
6500
82
82
52
82
82
82
82
76
COMPACT FLUORESCENT COMPETITIVE GUIDES
NOTE: These tables are intended only as guides and may represent another lamp company’s most similar product or product family rather
than an identical match. Individual manufacturer’s performance values should be consulted. Environmental conditions, ballast type, and other
auxiliary equipment may affect lamp performance.
COMPACT FLUORESCENT BRAND NAMES
SYLVANIA
GE*
PHILIPS**
DULUX®
BIAX
PL
DULUX S
Low wattage BIAX
PL
DULUX D, D/E
Double BIAX
PL-C
DULUX T, T/E
Triple BIAX
PL-T
DULUX F
----DULUX L
High Lumen BIAX
PL-L
DULUX EL
Spiral
Marathon Twister
--2D
--DURA-ONE™
GENURA
--ECOLOGIC® (ECO®)
Ecolux (ECO)
ALTO
* Trademarks or registered trademarks of General Electric Company ** Trademarks or registered trademarks of Philips
COMPACT FLUORESCENT COLOR CROSS REFERENCE
SYLVANIA
GE
PHILIPS
827
830
835
841
850
865
950
SPX27
SPX30
SPX35
SPX41
SPX50
SPX65
27
30, 830
35, 835
41, 841
50, 850
865
950
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 124
109
050_CFL_drop.qxd
12/12/07
3:50 PM
Page 110
COMPACT FLUORESCENT LAMPS
The overall length of DULUX® compact fluorescent lamps is measured from the bottom of the base to the outside edge of the glass. In many cases, the bottom of the base is the bottom of the center post of the base of the lamp.
C
O
M
P
A
C
T
DULUX S
DULUX S/E
DULUX D
DULUX D/E
DULUX T
DULUX T/E
DULUX T/E/IN
DULUX EL Low
Profile GLOBE
DULUX EL
GLOBE
F
L
U
O
R
E
S
C
E
N
T
DULUX L
DULUX
EL Triple
DULUX EL
REFLECTOR
DULUX F
DULUX
EL TWIST
BR-30
DULUX EL CLASSIC
(A-Shape)
PAR-38
For more complete product information visit www.sylvania.com
110
DULUX EL
BULLET
DULUX EL Circline (6-1/2"
& 8" outside diameters)
BR40 Med
DULUX EL
DECOR
PAR38 Med
Skrt
Symbols/Footnotes on page 124
050_CFL_drop.qxd
12/12/07
3:50 PM
Page 111
BASES
Pin-based compact fluorescent lamps have either 2 pins or 4 pins. Each 2-pin lamp has an internal starter and is designed for preheat, magnetic operation.
The 4-pin lamps are designed for electronic ballast operation and are dimmable. These lamps have no internal starter; starting the lamps is a function of
the ballast.
Medium screw base, compact fluorescent lamps have integral ballasts.
FOR CHOKE/STARTER OPERATION
C
O
M
P
A
C
T
GX 23
G 23
G 24 d2
GX 23-2
G 23-2
F
L
U
O
R
E
S
C
E
N
T
G24 d3
FOR ELECTRONIC OR DIMMING OPERATION
G 24 q-1
GX 24 d-2
G 24 q-3
G 24 q-2
GX 24 d-3
2 G 11
GX 24 q-1
For more complete product information visit www.sylvania.com
2G7
GX 24 q-2
2 GX 7
GX 24
Medium Screw Base
or DULUX® EL
GX 24 q-3
GX 24 q-4
GX 24 q-5
Symbols/Footnotes on page 124
111
050_CFL_drop.qxd
12/12/07
3:50 PM
Page 112
SYLVANIA DULUX® COMPACT FLUORESCENT CROSS REFERENCE
DULUX S
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
WATTAGE
BASE
20325
20303
20327
20310
20304
20307
20329
20333
20305
20308
20331
20283
20335
20306
20309
20374
20397
20368
20375
CF5DS/827
CF5DS/841
CF7DS/827
CF7DS/835
CF7DS/841
CF7DS/850
CF9DS/827
CF9DS/835
CF9DS/841
CF9DS/850
CF13DS/827
CF13DS/830
CF13DS/835
CF13DS/841
CF13DS/850
CFT13WDS/EC/827
CFT13WDS/EC/830
CFT13WDS/EC/835
CFT13WDS/EC/841
CFT5W/G23/827
CFT5W/G23/827
CFT7W/G23/827
CFT7W/G23/835
CFT7W/G23/841
CFT7W/G23/850
CFT9W/G23/827
CFT9W/G23/835
CFT9W/G23/841
CFT9W/G23/850
CFT13W/GX23/827
CFT13W/GX23/830
CFT13W/GX23/835
CFT13W/GX23/841
CFT13W/GX23/850
CFT13W/GX23/827
CFT13W/GX23/830
CFT13W/GX23/835
CFT13W/GX23/841
F5BX/SPX27
F5BX/SPX41
F7BX/SPX27
F7BX/SPX35
F7BX/SPX41
—
F9BX/SPX27
F9BX/SPX35
F9BX/SPX41
—
F13BX/SPX27
F13BX/SPX30
F13BX/SPX35
F13BX/SPX41
F13BX/SPX50
F13BX/E/827
F13BX/E/830
F13BX/E/835
F13BX/E/841
PL-S 5W/827
—
PL-S 7W/827
PL-S 7W/835
PL-S 7W/841
PL-S 7W/850
PL-S 9W/827
PL-S 9W/835
PL-S 9W/841
PL-S 9W/850
PL-S 13W/827
PL-S 13W/830
PL-S 13W/835
PL-S 13W/841
PL-S 13W/850
—
—
—
—
5
5
7
7
7
7
9
9
9
9
13
13
13
13
13
13
13
13
13
G23
G23
G23
G23
G23
G23
G23
G23
G23
G23
GX23
GX23
GX23
GX23
GX23
GX23
GX23
GX23
GX23
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
WATTAGE
BASE
20311
20315
20312
20316
20313
20317
20314
20284
20318
CF5DS/E/827
CF5DS/E/841
CF7DS/E/827
CF7DS/E/841
CF9DS/E/827
CF9DS/E/841
CF13DS/E/827
CF13DS/E/830
CF13DS/E/841
CFT5W/2G7/827
CFT5W/2G7/841
CFT7W/2G7/827
CFT7W/2G7/841
CFT9W/2G7/827
CFT9W/2G7/841
CFT13W/2GX7/827
CFT13W/2GX7/830
CFT13W/2GX7/841
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5
5
7
7
9
9
13
13
13
2G7
2G7
2G7
2G7
2G7
2G7
2GX7
2GX7
2GX7
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
WATTAGE
BASE
20689
20783
20690
20691
20705
20692
20708
20676
20709
20677
20678
20679
20710
20680
20681
CF9DD/827
CF9DD/830
CF9DD/835
CF13DD/827
CF13DD/830
CF13DD/835
CF13DD/841
CF18DD/827
CF18DD/830
CF18DD/835
CF18DD/841
CF26DD/827
CF26DD/830
CF26DD/835
CF26DD/841
CFQ9W/G23/827
CFQ9W/G23/830
CFQ9W/G23/835
CFQ13W/GX23/827
CFQ13W/GX23/830
CFQ13W/GX23/835
CFQ13W/GX23/841
CFQ18W/G24d/827
CFQ18W/G24d/830
CFQ18W/G24d/835
CFQ18W/G24d/841
CFQ26W/G24d/827
CFQ26W/G24d/830
CFQ26W/G24d/835
CFQ26W/G24d/841
F9DBX23T4/SPX27
—
—
F13DBX23T4/SPX27
F13DBX23T4/SPX30
F13DBX23T4/SPX35
F13DBX23T4/SPX41
F18DBXT4/SPX27
F18DBXT4/SPX30
F18DBXT4/SPX35
F18DBXT4/SPX41
F26DBXT4/SPX27
F26DBXT4/SPX30
F26DBXT4/SPX35
F26DBXT4/SPX41
—
—
—
PL-C 13W/827/USA
PL-C 13W/830/USA
PL-C 13W/835/USA
PL-C 13W/841/USA
PL-C 18W/827
PL-C 18W/830
PL-C 18W/835
PL-C 18W/841
PL-C 26W/827
PL-C 26W/830
PL-C 26W/835
PL-C 26W/841
9
9
9
13
13
13
13
18
18
18
18
26
26
26
26
G23-2
G23-2
G23-2
GX23-2
GX23-2
GX23-2
GX23-2
G24 d-2
G24 d-2
G24 d-2
G24 d-2
G24 d-3
G24 d-3
G24 d-3
G24 d-3
DULUX S/E
DULUX D
DULUX D/E
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
WATTAGE
BASE
20682
20721
20671
20667
20683
20724
20672
20668
20684
20722
20673
20669
CF13DD/E/827
CF13DD/E/830
CF13DD/E/835
CF13DD/E/841
CF18DD/E/827
CF18DD/E/830
CF18DD/E/835
CF18DD/E/841
CF26DD/E/827
CF26DD/E/830
CF26DD/E/835
CF26DD/E/841
CFQ13W/G24q/827
CFQ13W/G24q/830
CFQ13W/G24q/835
CFQ13W/G24q/841
CFQ18W/G24q/827
CFQ18W/G24q/830
CFQ18W/G24q/835
CFQ18W/G24q/841
CFQ26W/G24q/827
CFQ26W/G24q/830
CFQ26W/G24q/835
CFQ26W/G24q/841
F13DBX/SPX27/4P
F13DBX/SPX30/4P
F13DBX/SPX35/4P
F13DBX/SPX41/4P
F18DBX/SPX27/4P
F18DBX/SPX30/4P
F18DBX/SPX35/4P
F18DBX/SPX41/4P
F26DBX/SPX27/4P
F26DBX/SPX30/4P
F26DBX/SPX35/4P
F26DBX/SPX41/4P
PL-C 13W/827/4P
PL-C 13W/830/4P
PL-C 13W/835/4P
PL-C 13W/841/4P
PL-C 18W/827/4P
PL-C 18W/830/4P
PL-C 18W/835/4P
PL-C 18W/841/4P
PL-C 26W/827/4P
PL-C 26W/830/4P
PL-C 26W/835/4P
PL-C 26W/841/4P
13
13
13
13
18
18
18
18
26
26
26
26
G24 q-1
G24 q-1
G24 q-1
G24 q-1
G24 q-2
G24 q-2
G24 q-2
G24 q-2
G24 q-3
G24 q-3
G24 q-3
G24 q-3
For more complete product information visit www.sylvania.com
112
Symbols/Footnotes on page 124
050_CFL_drop.qxd
12/12/07
3:50 PM
Page 113
SYLVANIA DULUX® COMPACT FLUORESCENT CROSS REFERENCE
DULUX T
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
20756
20752
CF18DT/827
CF26DT/827
CFQ18W/GX24d/827
CFQ26W/GX24d/827
—
—
—
—
WATTAGE
18
26
BASE
GX24 d-2
GX24 d-3
DULUX T/E
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
20891
20892
20893
20894
20760
20767
20768
CF13DT/E/827
CF13DT/E/830
CF13DT/E/835
CF13DT/E/841
CF18DT/E/827
CF26DT/E/827
CF32DT/E/827
CFTR13W/GX24q/827
CFTR13W/GX24q/830
CFTR13W/GX24q/835
CFTR13W/GX24q/841
CFTR18W/GX24q/827
CFTR26W/GX24q/827
CFTR32W/GX24q/827
F13TBX/827/4P/EOL
—
—
—
F18TBX/827/4P/EOL
F26TBX/827/4P/EOL
—
—
—
—
—
—
—
—
WATTAGE
13
13
13
13
18
26
32
BASE
GX24 q-1
GX24 q-1
GX24 q-1
GX24 q-1
GX24 q-2
GX24 q-3
GX24 q-3
C
O
M
P
A
C
T
DULUX T/E/IN
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
20875
20876
20877
20878
20879
20880
20881
20882
20883
20884
20885
20886
20887
20888
20871
20890
20895
20896
20897
20899
20794
20795
20796
20797
CF18DT/E/IN/827
CF18DT/E/IN/830
CF18DT/E/IN/835
CF18DT/E/IN/841
CF26DT/E/IN/827
CF26DT/E/IN/830
CF26DT/E/IN/835
CF26DT/E/IN/841
CF32DT/E/IN/827
CF32DT/E/IN/830
CF32DT/E/IN/835
CF32DT/E/IN/841
CF42DT/E/IN/827
CF42DT/E/IN/830
CF42DT/E/IN/835
CF42DT/E/IN/841
CF57DT/E/IN/827
CF57DT/E/IN/830
CF57DT/E/IN/835
CF57DT/E/IN/841
CF70DT/E/IN/827
CF70DT/E/IN/830
CF70DT/E/IN/835
CF70DT/E/IN/841
CFTR18W/GX24q/827
CFTR18W/GX24q/830
CFTR18W/GX24q/835
CFTR18W/GX24q/841
CFTR26W/GX24q/827
CFTR26W/GX24q/830
CFTR26W/GX24q/835
CFTR26W/GX24q/841
CFTR32W/GX24q/827
CFTR32W/GX24q/830
CFTR32W/GX24q/835
CFTR32W/GX24q/841
CFTR42W/GX24q/827
CFTR42W/GX24q/830
CFTR42W/GX24q/835
CFTR42W/GX24q/841
CFTR57W/GX24q/827
CFTR57W/GX24q/830
CFTR57W/GX24q/835
CFTR57W/GX24q/841
CFTR70W/GX24q/827
CFTR70W/GX24q/830
CFTR70W/GX24q/835
CFTR70W/GX24q/841
F18TBX/SPX27/A/4P
F18TBX/SPX30/A/4P
F18TBX/SPX35/A/4P
F18TBX/SPX41/A/4P
F26TBX/SPX27/A/4P
F26TBX/SPX30/A/4P
F26TBX/SPX35/A/4P
F26TBX/SPX41/A/4P
F32TBX/SPX27/A/4P
F32TBX/SPX30/A/4P
F32TBX/SPX35/A/4P
F32TBX/SPX41/A/4P
F42TBX/827/A/4P/EOL
F42TBX/830/A/4P/EOL
F42TBX/835/A/4P/EOL
F42TBX/841/A/4P/EOL
F57QBX/827/A/4P/EOL
F57QBX/830/A/4P/EOL
F57QBX/835/A/4P/EOL
F57QBX/841/A/4P/EOL
F70QBX/827/A/4P/EOL
F70QBX/830/A/4P/EOL
F70QBX/835/A/4P/EOL
F70QBX/841/A/4P/EOL
PL-T 18W/827/4P
PL-T 18W/830/4P
PL-T 18W/835/4P
PL-T 18W/841/4P
PL-T 26W/827/4P
PL-T 26W/830/4P
PL-T 26W/835/4P
PL-T 26W/841/4P
PL-T 32W/827/4P
PL-T 32W/830/4P
PL-T 32W/835/4P
PL-T 32W/841/4P
PL-T 42W/827/4P
PL-T 42W/830/4P
PL-T 42W/835/4P
PL-T 42W/841/4P
—
PL-T 57W/830/4P/A
PL-T 57W/835/4P/A
PL-T 57W/841/4P/A
—
—
—
—
WATTAGE
18
18
18
18
26
26
26
26
32
32
32
32
42
42
42
42
57
57
57
57
70
70
70
70
F
L
U
O
R
E
S
C
E
N
T
BASE
GX24 q-2
GX24 q-2
GX24 q-2
GX24 q-2
GX24 q-3
GX24 q-3
GX24 q-3
GX24 q-3
GX24 q-3
GX24 q-3
GX24 q-3
GX24 q-3
GX24 q-4
GX24 q-4
GX24 q-4
GX24 q-4
GX24 q-5
GX24 q-5
GX24 q-5
GX24 q-5
GX24 q-6
GX24 q-6
GX24 q-6
GX24 q-6
DULUX L
NAED
SYLVANIA
NEMA / GENERIC
GE
PHILIPS
20587
20595
20588
20594
20589
20593
20597
20580
20596
20581
20582
20583
20518
20519
20488
20584
20585
20586
20576
20554
20590
20591
20592
20563
20572
20622
20624
FT18DL830
FT18DL830RS
FT18DL835
FT18DL835RS
FT18DL841
FT18DL841RS
FT24DL830
FT24DL835
FT24DL841
FT36DL830
FT36DL835
FT36DL841
FT40DL/28W/830/SS/IS
FT40DL/28W/835/SS/IS
FT40DL/28W/841/SS/IS
FT40DL830RS
FT40DL835RS
FT40DL841RS
FT40DL850RS
FT40DL965RS
FT55DL830
FT55DL835
FT55DL841
FT55DL965
FT80DL830
FT80DL835
FT80DL841
FT18W/2G11/830
FT18W/2G11/RS/830
FT18W/2G11/835
FT18W/2G11/RS/835
FT18W/2G11/841
FT18W/2G11/RS/841
FT24W/2G11/830
FT24W/2G11/835
FT24W/2G11/841
FT36W/2G11/830
FT36W/2G11/835
FT36W/2G11/841
FT40W/2G11/RS/830
FT40W/2G11/RS/835
FT40W/2G11/RS/841
FT40W/2G11/RS/830
FT40W/2G11/RS/835
FT40W/2G11/RS/841
FT40W/2G11/RS/850
FT40W/2G11/RS/865
FT55W/2G11/RS/830
FT55W/2G11/RS/835
FT55W/2G11/RS/841
FT55W/2G11/RS/965
FT80W/2G11/RS/830
FT80W/2G11/RS/835
FT80W/2G11/RS/841
F18BX/SPX30
F18BX/SPX30/RS
F18BX/SPX35
F18BX/SPX35/RS
F18BX/SPX41
F18BX/SPX41/RS
F27BX/SPX30/RS
F27BX/SPX35/RS
F27BX/SPX41/RS
F39BX/SPX30/RS
F39BX/SPX35/RS
F39BX/SPX41/RS
—
—
—
F40/30BX/SPX30
F40/30BX/SPX35
F40/30BX/SPX41
F40/30BX/SPX50RS
—
F55BX/830
F55BX/835
F55BX/841
—
—
—
—
PL-L 18W/830
PL-L 18W/830
PL-L 18W/835
PL-L 18W/835
PL-L 18W/841
PL-L 18W/841
PL-L 24W/830
PL-L 24W/835
PL-L 24W/841
PL-L 36W/830
PL-L 36W/835
PL-L 36W/841
—
—
—
PL-L 40W/830/RS/IS
PL-L 40W/835/RS/IS
PL-L 40W/841/RS/IS
—
—
—
—
—
—
PL-L 80W/830/4P
PL-L 80W/835/4P
PL-L 80W/841/4P
For more complete product information visit www.sylvania.com
WATTAGE
18
18
18
18
18
18
24
24
24
36
36
36
28
28
28
40
40
40
40
40
55
55
55
55
80
80
80
BASE
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
2G11
Symbols/Footnotes on page 124
113
050_CFL_print.qxd
12/17/07
8:41 AM
Page 114
DULUX® S
DULUX S PREHEAT 2-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS
With starter in Lamp Base for Magnetic Ballast
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
Product
Number Ordering Abbreviation
NEMA
Generic Designation
Pkg
Qty
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
5
4.2
20547
CFT5W/G23/827
10
10000
S (T4)
107
G23
CF5DS/827/RP/ECO
2700 82
230
198
|
|
|
1,4,6,11,
12,20,22
20325
CF5DS/827/ECO
CFT5W/G23/827
50
10000
2700 82
230
198
1,4,6,11,
12,20,22
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
20303
CF5DS/841/ECO
CFT5W/G23/841
50
10000
4100 82
230
198
1,4,6,11,
12,20,22
7
S (T4)
5.3
135
G23
20548
CF7DS/827/RP/ECO
CFT7W/G23/827
10
10000
2700 82
400
344
1,4,6,11,
12,20,22
20327
CF7DS/827/ECO
CFT7W/G23/827
50
10000
2700 82
400
344
1,4,6,11,
12,20,22
20310
CF7DS/835/ECO
CFT7W/G23/835
50
10000
3500 82
400
344
1,4,6,11,
12,20,22
20304
CF7DS/841/ECO
CFT7W/G23/841
50
10000
4100 82
400
344
1,4,6,11,
12,20,22
20307
CF7DS/850/ECO
CFT7W/G23/850
50
10000
5000 82
400
344
1,4,6,11,
12,20,22
9
S (T4)
6.5
165
G23
20536
CF9DS/827/RP/ECO
CFT9W/G23/827
10
10000
2700 82
580
499
1,4,6,11,
12,20,22
20329
CF9DS/827/ECO
CFT9W/G23/827
50
10000
2700 82
580
499
1,4,6,11,
12,20,22
20299
DULUX S 9W/78
20333
CF9DS/835/ECO
CFT9W/G23/835
50
10000
50
10000
1,4,10,11,12,22
3500 82
580
499
1,4,6,11,
12,20,22
20305
CF9DS/841/ECO
CFT9W/G23/841
50
10000
4100 82
580
499
1,4,6,11,
12,20,22
20308
CF9DS/850/ECO
CFT9W/G23/850
50
10000
5000 82
580
499
1,4,6,11,
12,20,22
13
S (T4)
7.1
180
GX23
20549
CF13DS/827/RP/ECO
CFT13W/GX23/827
10
10000
2700 82
800
688
1,4,6,11,
12,20,22
20331
CF13DS/827/ECO
CFT13W/GX23/827
50
10000
2700 82
800
688
1,4,6,11,
12,20,22
20283
CF13DS/830/ECO
CFT13W/GX23/830
50
10000
3000 82
800
688
1,4,6,11,
12,20,22
20335
CF13DS/835/ECO
CFT13W/GX23/835
50
10000
3500 82
800
688
1,4,6,11,
12,20,22
20306
CF13DS/841/ECO
CFT13DS/GX23/841
50
10000
4100 82
800
688
1,4,6,11,
12,20,22
20309
CF13DS/850/ECO
CFT13W/GX23/850
50
10000
5000 82
800
688
1,4,6,11,
12,20,22
20374
CFT13WDS/EC/827/ECO
CFT13W/GX23/827
10
10000
2700 82
800
688
1,2,4,11,12,20
20397
CFT13WDS/EC/830/ECO
CFT13W/GX23/830
10
10000
3000 82
800
688
1,2,4,11,12,20
20368
CFT13WDS/EC/835/ECO
CFT13W/GX23/835
10
10000
3500 82
800
688
1,2,4,11,12,20
20375
CFT13WDS/EC/841/ECO
CFT13W/GX23/841
10
10000
4100 82
800
688
1,2,4,11,12,20
For more complete product information visit www.sylvania.com
114
Symbols/Footnotes on page 124
050_CFL_print.qxd
12/17/07
8:41 AM
DULUX® S/E
Page 115
DULUX® D
DULUX S/E 4-PIN COMPACT FLUORESCENT LAMPS
for Dimming and Electronic Ballast. Lamps have End-of-lamp Life (EOL) Protection
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
5
3.4
7
9
13
S (T4)
S (T4)
S (T4)
S (T4)
4.5
5.7
6.2
85
115
145
157
2G7
2G7
2G7
2GX7
Product
Number Ordering Abbreviation
NEMA
Generic Designation
Pkg
Qty
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
20311
CF5DS/E/827
CFT5W/2G7/827
50
10000
2700 82
230
198
1,2,5,12,16,20
20315
CF5DS/E/841
CFT5W/2G7/841
50
10000
4100 82
230
198
1,2,5,12,16,20
20312
CF7DS/E/827
CFT7W/2G7/827
50
10000
2700 82
400
344
1,2,5,12,16,20
20316
CF7DS/E/841
CFT7W/2G7/841
50
10000
4100 82
400
344
1,2,5,12,16,20
20313
CF9DS/E/827
CFT9W/2G7/827
50
10000
2700 82
580
499
1,2,5,12,20
20317
CF9DS/E/841
CFT9W/2G7/841
50
10000
4100 82
580
499
1,2,5,12,20
20314
CF13DS/E/827
CFT13W/2GX7/827
50
10000
2700 82
800
688
1,2,5,12,20
20284
CF13DS/E/830
CFT13W/2GX7/830
50
10000
3000 82
800
688
1,2,5,12,20
20318
CF13DS/E/841
CFT13W/2GX7/841
50
10000
4100 82
800
688
1,2,5,12,20
|
|
|
®
DULUX D PREHEAT 2-PIN ECOLOGIC COMPACT FLUORESCENT LAMPS
With starter in Lamp Base for Magnetic Ballast
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
Product
Number Ordering Abbreviation
NEMA
Generic Designation
Pkg
Qty
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
9
4.3
20537
CFQ9W/G23/827
10
10000
D (T4)
110
G23-2
CF9DD/827/RP/ECO
2700 82
525
452
|
|
|
1,4,6,11,
12,20,22
20689
CF9DD/827/ECO
CFQ9W/G23/827
50
10000
2700 82
525
452
1,4,6,11,
12,20,22
20783
CF9DD/830/ECO
CFQ9W/G23/830
50
10000
3000 82
525
452
1,4,6,11,
12,20,22
20690
CF9DD/835/ECO
CFQ9W/G23/835
50
10000
3500 82
525
452
1,4,6,11,
12,20,22
13
D (T4)
4.6
118
GX23-2
20691
CF13DD/827/ECO
CFQ13W/GX23/827
50
10000
2700 82
780
671
1,4,6,11,
12,20,22
20705
CF13DD/830/ECO
CFQ13W/GX23/830
50
10000
3000 82
780
671
1,4,6,11,
12,20,22
20692
CF13DD/835/ECO
CFQ13W/GX23/835
50
10000
3500 82
780
671
1,4,6,11,
12,20,22
20708
CF13DD/841/ECO
CFQ13W/GX23/841
50
10000
4100 82
780
671
1,4,6,11,
12,20,22
18
D (T4)
6.0
153
G24D-2
20676
CF18DD/827/ECO
CFQ18W/G24D/827
50
10000
2700 82
1150
989
1,4,6,11,
12,20,22
20709
CF18DD/830/ECO
CFQ18W/G24D/830
50
10000
3000 82
1150
989
1,4,6,11,
12,20,22
20677
CF18DD/835/ECO
CFQ18W/G24D/835
50
10000
3500 82
1150
989
1,4,6,11,
12,20,22
20678
CF18DD/841/ECO
CFQ18W/G24D/841
50
10000
4100 82
1150
989
1,4,6,11,
12,20,22
26
D (T4)
6.8
173
G24D-3
20679
CF26DD/827/ECO
CFQ26W/G24D/827
50
10000
2700 82
1710
1470
1,4,6,11,
12,20,22
20710
CF26DD/830/ECO
CFQ26W/G24D/830
50
10000
3000 82
1710
1470
1,4,6,11,
12,20,22
20680
CF26DD/835/ECO
CFQ26W/G24D/835
50
10000
3500 82
1710
1470
1,4,6,11,
12,20,22
20681
CF26DD/841/ECO
CFQ26W/G24D/841
50
10000
4100 82
1710
1470
1,4,6,11,
12,20,22
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 124
115
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
050_CFL_print.qxd
12/17/07
DULUX® D
8:41 AM
Page 116
DULUX® T
DULUX® D/E 4-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS
for Dimming and Electronic Ballast. Lamps have End-of-lamp Life (EOL) Protection
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
Product
Number Ordering Abbreviation
NEMA
Generic Designation
Pkg
Qty
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
13
5.2
20682
CFQ13W/G24Q/827
50
12000
D (T4)
131
G24Q-1
CF13DD/E/827/ECO
2700 82
900
774
|
|
|
1,2,5,6,
7,12,20
20721
CF13DD/E/830/ECO
CFQ13W/G24Q/830
50
12000
3000 82
900
774
1,2,5,6,
7,12,20
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
20671
CF13DD/E/835/ECO
CFQ13W/G24Q/835
50
12000
3500 82
900
774
1,2,5,6,
7,12,20
20667
CF13DD/E/841/ECO
CFQ13W/G24Q/841
50
12000
4100 82
900
774
1,2,5,6,
7,12,20
18
D (T4)
5.8
147
G24Q-2
20683
CF18DD/E/827/ECO
CFQ18W/G24Q/827
50
12000
2700 82
1150
989
1,2,5,6,
7,12,20
20724
CF18DD/E/830/ECO
CFQ18W/G24Q/830
50
12000
3000 82
1150
989
1,2,5,6,
7,12,20
20672
CF18DD/E/835/ECO
CFQ18W/G24Q/835
50
12000
3500 82
1150
989
1,2,5,6,
7,12,20
20668
CF18DD/E/841/ECO
CFQ18W/G24Q/841
50
12000
4100 82
1150
989
1,2,5,6,
7,12,20
26
D (T4)
6.5
166
G24Q-3
20684
CF26DD/E/827/ECO
CFQ26W/G24Q/827
50
12000
2700 82
1710
1470
1,2,5,6,
7,12,20
20722
CF26DD/E/830/ECO
CFQ26W/G24Q/830
50
12000
3000 82
1710
1470
1,2,5,6,
7,12,20
20673
CF26DD/E/835/ECO
CFQ26W/G24Q/835
50
12000
3500 82
1710
1470
1,2,5,6,
7,12,20
20669
CF26DD/E/841/ECO
CFQ26W/G24Q/841
50
12000
4100 82
1710
1470
1,2,5,6,
7,12,20
DULUX T PREHEAT 2-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS
With starter in Lamp Base for Magnetic Ballast
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
18
4.8
T (T4)
123
Product
Number Ordering Abbreviation
GX24D-2 20756
CF18DT/827/ECO
NEMA
Generic Designation
Pkg
Qty
CFTR18W/GX24D/827 50
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
12000
2700 82
1200
1032
|
|
|
1,4,6,11,
12,20,22
26
T (T4)
5.4
138
GX24D-3 20752
CF26DT/827/ECO
CFTR26W/GX24D/827 50
12000
2700 82
1800
1548
1,4,6,11,
12,20,22
DULUX T/E 4-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS
For dimming and electronic ballast. Lamps have End-of-Lamp Life (EOL) Protection
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
13
4.2
T (T4)
106
Product
Number Ordering Abbreviation
GX24Q-1 20891
CF13DT/E/827/ECO
NEMA
Generic Designation
Pkg
Qty
CFTR13W/GX24Q/827 50
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
12000
2700 82
900
774
|
|
|
1,2,5,6,
7,12,20
20892
CF13DT/E/830/ECO
CFTR13W/GX24Q/830 50
12000
3000 82
900
774
1,2,5,6,
7,12,20
20893
CF13DT/E/835/ECO
CFTR13W/GX24Q/835 50
12000
3500 82
900
774
1,2,5,6,
7,12,20
20894
CF13DT/E/841/ECO
CFTR13W/GX24Q/841 50
12000
4100 82
900
774
1,2,5,6,
7,12,20
18
T (T4)
4.6
116
GX24Q-2 20760
CF18DT/E/827/ECO
CFTR18W/GX24Q/827 50
12000
2700 82
1200
1032
1,2,5,6,
7,12,20
For more complete product information visit www.sylvania.com
116
Symbols/Footnotes on page 124
050_CFL_print.qxd
12/17/07
8:41 AM
Page 117
DULUX® T
DULUX® D/E 4-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
26
5.2
T (T4)
124
Product
Number Ordering Abbreviation
GX24Q-3 20767
CF26DT/E/827/ECO
NEMA
Generic Designation
Pkg
Qty
CFTR26W/GX24Q/827 50
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
12000
2700 82
1800
1548
|
|
|
1,2,5,6,
7,12,20
20995
CF26DT/E/835/ECO/BL/1
CFTR26W/GX24Q/835 50
12000
3500 82
1800
1548
1,2,5,6,
7,12,20
32
T (T4)
5.8
147
GX24Q-3 20768
CF32DT/E/827/ECO
CFTR32W/GX24Q/827 50
12000
2700 82
2400
2064
1,2,5,6,
7,12,18,20
DULUX T/E/IN AMALGAM, 4-PIN ECOLOGIC COMPACT FLUORESCENT LAMPS
For electronic ballast for high and low temperature applications. Lamps have End-of-Lamp Life (EOL) Protection
42
Avg
Nominal
Wattage Bulb
(in)
18
4.4
T (T4)
MOL
(mm) Base
111
Product
Number Ordering Abbreviation
GX24Q-2 20875
20876
20877
20878
26
T (T4)
5.0
126
GX24Q-3 20879
20880
20881
20882
32
T (T4)
5.6
142
GX24Q-3 20883
20884
20885
20886
42
T (T4)
6.5
163
GX24Q-4 20887
20888
20871
20890
57
T (T4)
7.76
197
GX24Q-5 20895
20896
20897
CF18DT/E/IN/827/ECO
CF18DT/E/IN/830/ECO
CF18DT/E/IN/835/ECO
CF18DT/E/IN/841/ECO
CF26DT/E/IN/827/ECO
CF26DT/E/IN/830/ECO
CF26DT/E/IN/835/ECO
CF26DT/E/IN/841/ECO
CF32DT/E/IN/827/ECO
CF32DT/E/IN/830/ECO
CF32DT/E/IN/835/ECO
CF32DT/E/IN/841/ECO
CF42DT/E/IN/827/ECO
CF42DT/E/IN/830/ECO
CF42DT/E/IN/835/ECO
CF42DT/E/IN/841/ECO
CF57DT/E/IN/827/ECO
CF57DT/E/IN/830/ECO
CF57DT/E/IN/835/ECO
For more complete product information visit www.sylvania.com
NEMA
Generic Designation
Pkg
Qty
CFTR18W/GX24Q/827 50
CFTR18W/GX24Q/830 50
CFTR18W/GX24Q/835 50
CFTR18W/GX24Q/841 50
CFTR26W/GX24Q/827 50
CFTR26W/GX24Q/830 50
CFTR26W/GX24Q/835 50
CFTR26W/GX24Q/841 50
CFTR32W/GX24Q/827 50
CFTR32W/GX24Q/830 50
CFTR32W/GX24Q/835 50
CFTR32W/GX24Q/841 50
CFTR42W/GX24Q/827 50
CFTR42W/GX24Q/830 50
CFTR42W/GX24Q/835 50
CFTR42W/GX24Q/841 50
CFTR57W/GX24Q/827 50
CFTR57W/GX24Q/830 50
CFTR57W/GX24Q/835 50
Approx Lumens
Avg
Initial
Mean
Rated
CCT
@25°C/77°F Symbols &
Life (hrs) (K) CRI @35°C/95°F Footnotes
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
12000
2700 82
3000 82
3500 82
4100 82
2700 82
3000 82
3500 82
4100 82
2700 82
3000 82
3500 82
4100 82
2700 82
3000 82
3500 82
4100 82
2700 82
3000 82
3500 82
1164
1200
1001
1032
7,12,20,21
1164
1200
1001
1032
7,12,20,21
1164
1200
1001
1032
7,12,20,21
1164
1200
1001
1032
7,12,20,21
1746
1800
1501
1548
7,12,20,21
1746
1800
1501
1548
7,12,20,21
1746
1800
1501
1548
7,12,20,21
1746
1800
1501
1548
7,12,20,21
2328
2400
2002
2064
7,12,18,20,21
2328
2400
2002
2064
7,12,18,20,21
2328
2400
2002
2064
7,12,18,20,21
2328
2400
2002
2064
7,12,18,20,21
3104
3200
2670
2752
7,12,18,20,21
3104
3200
2670
2752
7,12,18,20,21
3104
3200
2670
2752
7,12,18,20,21
3104
3200
2670
2752
7,12,18,20,21
4171
4300
3587
3698
12,18,20,21
4171
4300
3587
3698
12,18,20,21
4171
4300
3587
3698
12,18,20,21
|
|
|
|
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
1,2,5,6,
Symbols/Footnotes on page 124
117
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
050_CFL_print.qxd
12/17/07
DULUX® T
8:41 AM
Page 118
DULUX® L
DULUX® T/E/IN AMALGAM, 4-PIN ECOLOGIC® COMPACT FLUORESCENT LAMPS
42
Avg
Nominal
Wattage Bulb
(in)
57
7.76
T (T4)
MOL
(mm) Base
197
Product
Number Ordering Abbreviation
GX24Q-5 20899
CF57DT/E/IN/841/ECO
NEMA
Generic Designation
Pkg
Qty
CFTR57W/GX24Q/841 50
Approx Lumens
Avg
Initial
Mean
Rated
CCT
@25°C/77°F Symbols &
Life (hrs) (K) CRI @35°C/95°F Footnotes
12000
4100 82
4171
4300
3587
3698
|
|
|
|
1,2,5,6,
7,12,18,20,21
DULUX L HIGH LUMEN ECOLOGIC® COMPACT FLUORESCENT LAMPS
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
Product
Number Ordering Abbreviation
NEMA
Generic Designation
Pkg
Qty
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
18
9.0
20587
FT18W/2G11/830
10
12000
L (T5)
229
2G11
FT18DL/830/ECO
3000 82
1250
1075
|
|
|
1,2,5,12,
20
20588
FT18DL/835/ECO
FT18W/2G11/835
10
12000
3500 82
1250
1075
1,2,5,12,
20
20589
FT18DL/841/ECO
FT18W/2G11/841
10
12000
4100 82
1250
1075
1,2,5,12,
20
L (T5)
10.5
267
2G11
20595
FT18DL/830/RS/ECO
FT18W/2G11/RS/830 10
20000
3000 82
1250
1075
1,2,5,12,
20
20594
FT18DL/835/RS/ECO
FT18W/2G11/RS/835 10
20000
3500 82
1250
1075
1,2,5,12,
20
20593
FT18DL/841/RS/ECO
FT18W/2G11/RS/841 10
20000
4100 82
1250
1075
1,2,5,12,
20
24
L (T5)
12.9
326
2G11
20597
FT24DL/830/ECO
FT24W/2G11/830
10
12000
3000 82
1800
1548
1,2,5,12,
16,20
20580
FT24DL/835/ECO
FT24W/2G11/835
10
12000
3500 82
1800
1548
1,2,5,12,
16,20
20596
FT24DL/841/ECO
FT24W/2G11/841
10
12000
4100 82
1800
1548
1,2,5,12,
16,20
36
L (T5)
16.6
422
2G11
20581
FT36DL/830/ECO
FT36W/2G11/830
10
12000
3000 82
2900
2494
1,2,5,12,
16,20
20582
FT36DL/835/ECO
FT36W/2G11/835
10
12000
3500 82
2900
2494
1,2,5,12,
16,20
20583
FT36DL/841/ECO
FT36W/2G11/841
10
12000
4100 82
2900
2494
1,2,5,12,
16,20
40
L (T5)
22.4
570
2G11
20518
FT40DL/28W/830/SS/IS/ECO FT28W/2G11/830
10
20000
3000 82
2800
2408
1,2,5,6,12,18,
20
22.6
573
2G11
20584
FT40DL/830/RS/ECO
FT40W/2G11/RS/830 10
20000
3000 82
3150
2709
1,2,5,12,
20
22.4
570
2G11
20519
FT40DL/28W/835/SS/IS/ECO FT28W/2G11/835
10
20000
3500 82
2800
2408
1,2,5,6,12,18,
20
22.6
573
2G11
20585
FT40DL/835/RS/ECO
FT40W/2G11/RS/835 10
20000
3500 82
3150
2709
1,2,5,12,
20
22.4
570
2G11
20488
FT40DL/28W/841/SS/IS/ECO FT28W/2G11/841
10
20000
4100 82
2800
2408
1,2,5,6,12,18,
20
22.6
573
2G11
20586
FT40DL/841/RS/ECO
FT40W/2G11/RS/841 10
20000
4100 82
3150
2709
1,2,5,12,
20
20576
FT40DL/850/RS/ECO
FT40W/2G11/RS/850 10
20000
5000 82
3150
2709
1,2,5,12,
20
50
L (T5)
22.6
573
2G11
20276
FT50DL/841/RS/ECO
FT50W/2G11/RS/841 10
14000
4100 82
4300
3655
1,2,5,12,
20
20278
FT50DL/835/RS/ECO
FT50W/2G11/RS/835 10
14000
3500 82
4300
3655
1,2,5,12,
20
For more complete product information visit www.sylvania.com
118
Symbols/Footnotes on page 124
050_CFL_print.qxd
12/17/07
8:41 AM
DULUX® L
Page 119
DULUX® F
DULUX® EL Twist
DULUX® L HIGH LUMEN ECOLOGIC® COMPACT FLUORESCENT LAMPS
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
Product
Number Ordering Abbreviation
NEMA
Generic Designation
50
22.6
20280
FT50W/2G11/RS/830 10
L (T5)
573
2G11
FT50DL/830/RS/ECO
Pkg
Qty
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
14000
3000 82
4300
3655
|
|
|
1,2,5,12,
20
55
L (T5)
21.1
535
2G11
20590
FT55DL/830/ECO
FT55W/2G11/830
10
12000
3000 82
4800
4128
1,2,5,12,
17,20
20726
FT55DL/930/ECO
FT55W/2G11/30
10
12000
3000 90
4800
4128
20591
FT55DL/835/ECO
FT55W/2G11/835
10
12000
3500 82
4800
4128
1,2,5,12,17,20
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
1,2,5,12,
17,20
20592
FT55DL/841/ECO
FT55W/2G11/841
10
12000
4100 82
4800
4128
1,2,5,12,
17,20
80
L (T5)
22.6
4.5
2G11
20725
FT55DL/954/ECO
FT55W/2G11/50
10
12000
5400 90
4800
4128
20572
FT80DL/830/ECO
FT80W/2G11/830
10
12000
3000 82
6000
5160
1,2,5,12,17,20
1,2,5,12,
17,20
573
2G11
20622
FT80DL/835/ECO
FT80W/2G11/835
10
12000
3500 82
6000
5160
1,2,5,12,
17,20
4.5
2G11
20624
FT80DL/841/ECO
FT80W/2G11/841
10
12000
4100 82
6000
5160
1,2,5,12,
17,20
DULUX F FLAT COMPACT FLUORESCENT LAMPS
42
Nominal
Wattage Bulb
MOL
(in) (mm) Base
Product
Number Ordering Abbreviation
NEMA
Generic Designation
Pkg
Qty
Avg
Approx Lumens
Rated
CCT
Initial
Mean Symbols &
Life (hrs) (K) CRI @25°C/77°F Footnotes
18
F (T5)
4.8
122
2G10
20551
CF18DF/830
CFM18W/2G10/830
10
10000
3000 82
1100
946
1,2,5,12,19,20
20552
CF18DF/841
CFM18W/2G10/841
10
10000
4100 82
1100
946
1,2,5,12,19,20
24
F (T5)
6.7
171
2G10
20553
CF24DF/830
CFM24W/2G10/830
10
10000
3000 82
1700
1462
1,2,5,12,19,20
20558
CF24DF/841
CFM24W/2G10/841
10
10000
4100 82
1700
1462
1,2,5,12,19,20
36
F (T5)
8.5
217
2G10
20559
CF36DF/830
CFM36W/2G10/830
10
10000
3000 82
2800
2408
1,2,5,12,19,20
20560
CF36DF/841
CFM36W/2G10/841
10
10000
4100 82
2800
2408
1,2,5,12,19,20
|
|
|
DULUX EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Mini Twist Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
7
4.4
MINITWIST
Avg
Base
Product
Number
Medium
29451
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF7EL/MINI/827
120
8000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
2700 82
375
300
|
|
|
1,3,8,
9,12,14,20
29379
CF7EL/MINI/830
120
6
8000
3000 82
375
300
1,3,8,
9,12,14,20
29371
CF7EL/MINI/830/BL
120
6
8000
3000 82
375
300
1,3,8,
9,12,14,20
4.2
Medium
29697
CF7EL/SUPER/830/BL
120
6
10000
3000 82
375
300
1,3,8,
9,12,14,20
11
MINITWIST
4.2
Medium
29766
CF11EL/SUPER/830/BL
120
6
10000
3000 82
600
480
1,3,8,
9,12,14,20
4.5
Medium
29378
CF11EL/MINI/830
120
6
8000
3000 82
600
480
1,3,8,
9,12,14,20
29364
CF11EL/MINI/830/BL
120
6
8000
3000 82
600
480
1,3,8,
9,12,14,20
13
MINITWIST
4.6
Medium
29409
CF13EL/MINI/827
120
6
10000
2700 82
800
640
1,3,8,
9,12,14,20
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 124
119
050_CFL_print.qxd
12/17/07
8:41 AM
Page 120
DULUX® EL Twist
DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Mini Twist Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
13
4.6
MINITWIST
Avg
Base
Product
Number
Medium
29727
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF13EL/MICRO/830/RP2
120
12000
12
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
3000 82
825
660
|
|
|
1,3,8,
9,12,14,20
4.5
Medium
29376
CF13EL/MINI/830
120
6
8000
3000 82
800
640
1,3,8,
9,12,14,20
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
4.2
Medium
29059
CF13EL/SUPER/827/BL
120
6
10000
2700 82
880
704
1,3,8,
9,12,14,20
29449
CF13EL/SUPER/830/BL
120
6
10000
3000 82
880
704
1,3,8,
9,12,14,20
29713
CF13EL/SUPER/835/BL
120
6
10000
3500 82
800
640
1,3,8,
9,12,14,20
4.6
Medium
29567
CF13EL/MINI/841
120
6
10000
4100 82
800
640
1,3,8,
9,12,14,20
4.2
Medium
29588
CF13EL/SUPER/850/BL
120
10
10000
5000 82
800
640
1,3,8,
9,12,14,20
29469
CF13EL/MINI/865/BL/CS10
120
10
10000
6500 82
800
640
1,3,8,
9,12,14,20
19
MINITWIST
5.2
Medium
29410
CF19EL/MINI/827
120
6
8000
2700 82
1200
960
1,3,8,
9,12,14,20
5.5
Medium
29396
CF19EL/MINI/830
120
6
8000
3000 82
1200
960
1,3,8,
9,12,14,20
4.7
Medium
29689
CF19EL/SUPER/830/BL
120
6
10000
3000 82
1200
960
1,3,8,
9,12,14,20
28950
CF19EL/SUPER/850/BL
120
6
10000
5000 82
1200
960
1,3,8,
9,12,14,20
29720
CF19EL/SUPER/865/BL
120
6
10000
6500 82
1200
960
1,3,8,
9,12,14,20
20
MINITWIST
4.2
Medium
29728
CF20EL/MICRO/830/RP2
120
12
12000
3000 82
1280
1024
1,3,8,
9,12,14,20
23
MINITWIST
4.6
Medium
29411
CF23EL/MINI/827
120
6
10000
2700 82
1600
1280
1,3,8,
9,12,14,20
4.4
Medium
29729
CF23EL/MICRO/830/RP2
120
12
12000
3000 82
1600
1280
1,3,8,
9,12,14,20
5.75
Medium
29397
CF23EL/MINI/830
120
6
8000
3000 82
1600
1280
1,3,8,
9,12,14,20
5.06
Medium
29692
CF23EL/SUPER/830/BL
120
6
10000
3000 82
1600
1280
1,3,8,
9,12,14,20
29714
CF23EL/SUPER/835/BL
120
6
10000
3500 82
1600
1280
1,3,8,
9,12,14,20
4.6
Medium
29564
CF23EL/MINI/841
120
6
10000
4100 82
1600
1280
1,3,8,
9,12,14,20
5.06
Medium
29690
CF23EL/SUPER/850/BL
120
6
10000
5000 82
1600
1280
1,3,8,
9,12,14,20
29716
CF23EL/SUPER/865/BL
120
6
10000
6500 82
1600
1280
1,3,8,
9,12,14,20
30
MINITWIST
4.93
Medium
29578
CF30EL/MINI/835/DAY/BL
120
5
6000
3500 82
2000
1600
1,3,8,
9,12,14,20
For more complete product information visit www.sylvania.com
120
Symbols/Footnotes on page 124
050_CFL_print.qxd
12/17/07
8:41 AM
DULUX® EL Twist
Page 121
DULUX® EL Classic
DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Twist Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
27
6.1
TWIST
Avg
Base
Product
Number
Medium
29390
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF27EL/TWIST/830
120
10000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
3000 82
1750
1400
|
|
|
1,3,8,
9,12,14,20
30
TWIST
5.13
Medium
29395
CF30EL/TWIST/830
120
6
10000
3000 82
2000
1600
1,3,8,
9,12,14,20
29392
CF30EL/TWIST/830/BL
120
5
6000
3000 82
2000
1600
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
1,3,8,
9,12,14,20
29415
CF30EL/TWIST/827
120
6
10000
2700 82
2000
1600
1,3,8,
9,12,14,20
40
TWIST
5.25
Medium
29147
CF40EL/TWIST/827
120
6
8000
2700 82
2600
2080
1,3,8,
9,12,14,20
29481
CF40EL/TWIST/830/BL
120
10
6000
3000 82
2600
2080
1,3,8,
9,12,14,20
65
TWIST
7.85
Medium
29508
CF65EL/TWIST/841
120
6
8000
4100 82
4200
3360
1,3,8,
9,12,14,20
12
19
28
TWIST
5.75
3CON Med
29523
29351
29349
CF28EL/3WAY/TWIST/827
CF28EL/3WAY/TWIST/830
CF28EL/3WAY/TWIST/830/BL
120
120
120
6
6
5
6000
6000
6000
2700 82
3000 82
3000 82
600
1100
1800
480
880
1440
9,12,14,20
600
1100
1800
480
880
1440
9,12,14,20
600
1100
1800
480
880
1440
9,12,14,20
1,3,8,
1,3,8,
1,3,8,
Classic (A-shape) Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
5
3.95
A15
Avg
Base
Product
Number
Medium
29743
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF5EL/A15/DIM/830
120
15000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
3000 82
200
160
|
|
|
1,3,8,
12,14,20
9
A19
4
Medium
29665
CF9EL/A19/827
120
6
8000
2700 82
450
360
1,3,8,
9,12,14,20
A15
4
Medium
29526
CF9EL/A15/830/BL2
120
12
8000
3000 82
450
360
1,3,8,
9,12,14,20
14
A19
4.75
Medium
29575
CF14EL/A19/827
120
6
6000
2700 82
800
640
1,3,8,
9,12,14,20
29468
CF14EL/A19/830
120
6
6000
3000 82
800
640
1,3,8,
9,12,14,20
5
Medium
29485
CF14EL/A19/830/BL
120
6
8000
3000 82
800
640
1,3,8,
9,12,14,20
4.75
Medium
29346
CF14EL/A19/Y/BL
120
5
6000
-
-
405
324
1,3,8,
9,12,14,20
Decorative Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
4
4.25
FLAME
Avg
Base
Product
Number
Candelabra
29135
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF4EL/B15/C/827
120
6000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
2700 82
160
128
|
|
|
1,3,8,
9,12,14,20
29121
CF4EL/B15/C/830/BL
120
6
6000
3000 82
160
128
1,3,8,
9,12,14,20
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 124
121
050_CFL_print.qxd
12/17/07
DULUX® EL Globe
8:41 AM
Page 122
DULUX® EL Reflector
FLAME
DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Decorative Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
5
5.06
FLAME
Avg
Base
Product
Number
Medium
29742
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF5EL/B10/DIM/830
120
25000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
3000 82
200
160
|
|
|
1,3,8,
9,12,14,20
7
FLAME
5.0
Medium
29039
CF7EL/B15/827
120
6
6000
2700 82
280
224
1,3,8,
9,12,14,20
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
29167
CF7EL/B15/830/BL
120
6
6000
3000 82
280
224
1,3,8,
9,12,14,20
9
FLAME
4.25
Candelabra
29584
CF9EL/B14/C/830/ADP/BL2
120
12
8000
3000 82
450
360
1,3,8,
9,12,14,20
Globe Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
9
4.25
G25
Avg
Base
Product
Number
Medium
29414
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF9EL/G25/827
120
8000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
2700 82
495
396
|
|
|
1,3,8,
9,12,14,20
29528
CF9EL/G25/830/BL2
120
12
8000
3000 82
495
396
1,3,8,
9,12,14,20
14
G30
5.5
Medium
29195
CF14EL/G30/830
120
6
6000
3000 82
700
560
1,3,8,
9,12,14,20
Reflector Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
9
3.94
R20
Avg
Base
Product
Number
Medium
29638
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF9EL/R20/827
120
8000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
2700 82
300
240
|
|
|
1,3,8,
9,12,14,20
29640
CF9EL/R20/830/BL
120
6
8000
3000 82
300
240
1,3,8,
9,12,14,20
14
R20
4.25
Medium
29624
CF14EL/R20/827
120
6
8000
2700 82
495
396
1,3,8,
9,12,14,20
29587
CF14EL/R20/830/BL
120
6
8000
3000 82
495
396
1,3,8,
9,12,14,20
15
BR30
5.5
Medium
29465
CF15EL/BR30/DIM/827
120
6
6000
2700 82
600
480
1,3,8,
9,12,14,20
29667
CF15EL/BR30/DIM/830/BL
120
6
8000
3000 82
600
480
1,3,8,
9,12,14,20
5.6
Medium
29539
CF15EL/BR30/850/BL
120
6
6000
5000 82
560
448
1,3,8,
9,12,14,20
16
BR30
5.7
Medium
29591
CF16EL/BR30/827
120
6
8000
2700 82
750
600
1,3,8,
9,12,14,20
29590
CF16EL/BR30/830
120
6
8000
3000 82
750
600
1,3,8,
9,12,14,20
19
PAR38
5.8
Medium
29581
CF19EL/PAR38/830
120
6
8000
3000 82
950
760
1,3,8,
9,12,14,20
20
BR40
6.5
Medium
29399
CF20EL/BR40/827
120
6
8000
2700 82
900
720
1,3,8,
9,12,14,20
29363
CF20EL/BR40/830
120
6
8000
3000 82
900
720
1,3,8,
9,12,14,20
23
PAR38
6.25
Medium
29359
CF23EL/PAR38/827
120
6
8000
2700 82
1200
960
1,3,8,
9,12,14,20
For more complete product information visit www.sylvania.com
122
Symbols/Footnotes on page 124
050_CFL_print.qxd
12/17/07
8:41 AM
DULUX® EL Dura-One
Page 123
DULUX® EL Bullet
DULUX® EL Reflector
DULUX® EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Reflector Compact Fluorescent Lamps
44
Nominal
Wattage Bulb
MOL
(in)
23
6.25
PAR38
Avg
Base
Product
Number
Medium
29897
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF23EL/PAR38/GL/827
120
8000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
2700 82
1000
800
|
|
|
1,3,8,
9,12,14,20
BR40
6.5
Medium
29442
CF23EL/BR40/830/BL
120
6
8000
3000 82
1250
1000
1,3,8,
9,12,14,20
PAR38
6.25
Medium
29586
CF23EL/PAR38/830/BL
120
6
8000
3000 82
1200
960
1,3,8,
9,12,14,20
DURA-ONE™ COMPACT FLUORESCENT LAMPS
44
Nominal
Wattage Bulb
MOL
(in)
Avg
20
A19
23
BR30
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
29537
CF20RC/A19/827
120
6
15000
2700 82
1200
960
29535
CF23RC/BR30/827
120
6
15000
2700 82
1100
880
Base
Product
Number
5.31
Medium
5.56
Medium
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
|
|
|
1,3,8,12,15,20
1,3,8,12,
15,20
LOW PROFILE BULLET AND CIRCLINE ELECTRONIC COMPACT FLUORESCENT LAMPS
44
Nominal
Wattage Bulb
MOL
(in)
14
5.5
BULLET
Avg
Base
Product
Number
Medium
29196
Ordering Abbreviation
Pkg
Voltage Qty
Avg
Rated
CCT
Life (hrs) (K)
CF14EL/T20/830
120
6000
6
Approx Lumens
Initial
Mean Symbols &
CRI @25°C/77°F Footnotes
3000 82
700
560
|
|
|
1,3,8,
9,12,14,20
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 124
123
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
050_CFL_print.qxd
12/17/07
8:41 AM
Page 124
SYMBOLS & FOOTNOTES FOR COMPACT FLUORESCENT LAMPS
Symbol
Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
This lamp is a High Color Rendering Lamp
Product is Canadian Standards Association approved for the Canadian market
Product is Underwriters Laboratories listed
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
Footnote
Description
1
2
3
4
Approximate initial lumens after 100 hours operation.
Minimum starting temperature is a function of the ballast; consult the ballast manufacturer.
Minimum starting temperature for DULUX EL lamps is 0˚ F, unless otherwise specified in product literature. .
2 pin CF lamps are not suitable for use in frequently cycled applications or with occupancy sensors. 2 pin CF lamps should never be installed
in 4 pin sockets regardless if lamp will fit.
There is a NEMA supported, industry issue where T2, T4, and T5 fluorescent and compact fluorescent lamps operated on high frequency ballasts may experience an abnormal end-of-life phenomenon. This end-of-life phenomenon can resulting one or both of the following: 1. Bulb
wall cracking near the lamp base. 2. The lamp can overheat in the base area and possibly melt the base and socket. NEMA recommends that
high frequency compact fluorescent ballasts have an end-of-life shutdown circuit which will safely and reliably shut down the system in the
rare event of an abnormal end-of-life failure mode described above. The final requirements of this system are yet to be defined by ANSI. For
additional information refer to NEMA papers on their WEBSITE at www.NEMA.org.
SYLVANIA ECOLOGIC fluorescent lamps are designed to pass the Federal Toxic Characteristic Leaching Procedure (TCLP) criteria for classification as non-hazardous waste in most states. TCLP test results are available upon request. Lamp disposal regulations may vary, check your
local & state regulations. For more information, please visit www.lamprecycle.org
This 4-pin DULUX lamp has an internal end-of-life mechanism (EOL) that shuts down the lamp preventing abnormal end-of life failure modes.
This lamp was designed for use with high frequency ballasts that do not have their own end-of-life (lamp) sensing circuits, but it is also compatible with high frequency ballasts that have their own end-of-life (lamp) sensing circuits.
DULUX Els meet CSA, FCC and UL requirements.
Caution: DULUX EL units cannot be used on dimming circuits, emergency exit fixtures or lights, electronic timers, photocells, lighted switches or any other switches that do not meet UL20 Sec. 7.6.15. In outdoor applications, use only in enclosed fixtures to avoid exposure to
weather. Use only on 120V, 60 Hz circuits. Never disassemble or modify lamp. Install or remove unit from fixture by grasping plastic base.
Best performance achieved when operated at 77degrees F (25 degrees C). 40 Watt lamp is designed for base down orientation only.
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.2m (8 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
2 pin CF lamps should never be installed in 4 pin sockets regardless if lamp will fit.
The life ratings of fluorescent lamps are based on 3 hr. burning cycles under specified conditions and with ballast meeting ANSI specifications. If burning cycle is increased, there will be a corresponding increase in the average hours life.
Caution: DULUX EL Circline units cannot be used on dimming circuits, emergency exit fixtures or lights, electronic timers, photocells or lighted switches. In outdoor applications, use only in enclosed fixtures to avoid exposure to weather. Use only on 120V, 60 Hz circuits.
Minimum starting temperature for DULUX EL lamps is 0 degrees F
Caution: Although DURA-ONE lamps can be used with occupancy sensors that have a fluorescent volt-amp rating, DURA-ONE lamps cannot
be used on any other dimming circuits, emergency exit fixtures or lights, electronic timers, photocells, lighted switches or any other switches
that do not meet UL20 Sec. 7.6.15. In outdoor applications, use only in enclosed fixtures to avoid exposure to weather. Use only on 120V, 60
Hz circuits. Never disassemble or modify lamp. Install or remove unit from fixture by grasping plastic base. Best performance achieved when
operated at 77˚F (25˚C). Operating temperature range of DURA-ONE lamps is -20˚F/-29˚C to 122˚F/50˚C.
These lamps may also be operated on rapid start circuits. On rapid start circuits the 24 watt lamp operates at 27 watts and the 36 watt lamp
operated at 39 watts. Rated lamp life is unchanged.
Lumen output rated on high frequency operation. 60 HZ operation would result in lower lumen output.
Lumen output and life rated on high frequency operation.
DULUX F lamps can typically be operated on DULUX L and PENTRON HO ballasts of the same/similar wattage. Check with the ballast manufacturer to verify lamp/ballast compatibility.
Rule of Thumb for Compact Fluorescent Lamps: Divide wattage of incandescent lamp by 4 to determine approximate wattage of compact fluorescent lamp that will provide similar light output.
Optimum light output for DULUX T/E IN amalgam compact fluorescent lamps occurs at approximately 35 deg. C/ 95 deg. F ambient temperature when the lamp is operated in the base up position. The lumen value listed refers to the optimum light output. Non-amalgam compact fluorescent lamps provide at least 90% light output from 60-100 degrees F in the base up position, the temperature range is narrower for horizontal or base down position.
Minimum starting temperature: CF5: -22 degrees F; CF7: -4 degrees F; CF9: 14 degrees F; CF13DS: 14 degrees F; CF13DD: -4 degrees F;
CF18DD: 5 degrees F; CF18DT: -4 degrees F; CF26: 14 degrees F.
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
For more complete product information visit www.sylvania.com
124
100_cref.qxd
12/13/07
9:44 AM
Page 125
Manufacturers’ Cross Reference
COMPACT FLUORESCENT LAMPS
SYLVANIA
GE
CF5DS/827/ECO
CF5DS/827/RP/ECO
CF5DS/841/ECO
CF7DS/827/ECO
CF7DS/827/RP/ECO
CF7DS/835/ECO
CF7DS/841/ECO
CF7DS/850/ECO
CF7EL/DECO/MEDIUM/1/BL
CF7EL/DECO/MEDIUM/2700K
CF7EL/MINITWIST/1
CF7EL/MINITWIST/2700K
CF9DD/827/ECO
CF9DD/835/ECO
CF9DS/827/ECO
CF9DS/827/RP/ECO
CF9DS/835/ECO
CF9DS/841/ECO
CF9DS/850/ECO
CF9EL/G25/2700K
CF9EL/R20/2700K
CF9WEL/FAN/2BL
CF11EL/MINITWIST/1
CF13DD/827/ECO
CF13DD/827/ECO/RP/1
CF13DD/827/RP/ECO
CF13DD/830/ECO
CF13DD/835/ECO
CF13DD/841/ECO
CF13DD/E/827/ECO
CF13DD/E/830/ECO
CF13DD/E/835/ECO
CF13DD/E/841/ECO
CF13DS/827/ECO
CF13DS/827/ECO/RP/1
CF13DS/830/ECO
CF13DS/835/ECO
CF13DS/841/ECO
CF13DS/841/ECO/RP/1
CF13DS/850/ECO
CF13DT/E/827/ECO
CF13DT/E/830/ECO
CF13DT/E/835/ECO
CF13DT/E/841/ECO
CF13EL/MINITWIST/2700K
CF13EL/MINITWIST/4100K
CF13EL/SUPERMINI/5K/1BL
CF13ELSUPERMINIBL 120V
CF14EL/A19
CF14EL/A19/1/BL/YELLOW
CF14EL/A19/2700K
CF14EL/G/830/MED
CF14EL/R20/2700K
CF15BR30DIMMABLE3000KBL
CF15EL/BR30/5000K/BL
CF15ELBR30/DIMMABLE/2700K
CF15ELBR30/DIMMABLE/2700K
CF15ELBR30DIMMABLERP3000K
CF16EL/BR30
CF16ELBR30/2700K
CF18DD/827/ECO
CF18DD/830/ECO
CF18DD/835/ECO
CF18DD/841/ECO
F5BX/SPX27/827
F5BX-SPX27_CD
F5BX/SPX41/840_10PK
F7BX/SPX27/827
F7BX/SPX27_CD
F7BX7/SPX35/825_10PK
F7BX/SPX41/840_10PK
F7BX/SPX50/850
FLE7/2/CAM/827
FLE7/2/CAM/827
--F9DBXT4/SPX41/827
--F9BX/SPX27/827_10PK
F9BX/SPX27_CD
F9BX/SPX35/835
F9BX/SPX41/840_10PK
F9BX/SPX50/850
FLE11/2/G25XL/CD_12
--FLE11/2/A17
--F13DBX23T4/SPX27
FL3DBX/SPX27/CD
FL3DBX/SPX27/CD
F13DBX23T4/SPX30
F13DBX23T4/SPX35
F13DBX23T4/SPX41
F13DBX/SPX27/4P
F13DBX/SPX30/4P
F13DBX/SPX35/4P
F13DBX/SPX41/4P
14650_F13BX/SPX27_#011
14650_F13BX/SPX27_#011
F13BX/SPX30/830
17048_F13BX/SPX35_#013
20434_F13BX/SPX41_#014
20434_F13BX/SPX41_#014
F13BX/SPX50/850
F13TBX/SPX27/A/4P
F13TBX/SPX30/A/4P
F13TBX/SPX35/A/4P
F13TBX/SPX41/A/4P
FLE13HT3/2/827
----FLE15/2/A21XL
FLE14/2/TC16/BUG
FLE15/A19/827
FLG15/E-120
--FLE15/2/DV/R30
--FLE15/2/DV/R30
FLE15/2/DV/R30
FLE15/2/DV/R30
--FLE15/A2/R30
F18DBXT4/SPX27
F18DBXT4/SPX30
F18DBXT4/SPX35
F18DBXT4/SPX41
PHILIPS
PL-S_5W/27
PL-S_5W/27
PL-S 5W/841/2P/ALTO
PL-S7W/27
PL-S7W/27
PL-S_7W/35
PL-S_7W/41
PL-S7W/50
BC-EL/MCAN9ALTO
----EL/MDT9
----PL-S9W/27
PL-S9W/27
PL-S9W/35
PL-S9W/41
PL-S9W/50
EL/AG25
----EL/mdT 11
PL-C_13W/27/USA
PL-C 13W/827/USA/ALTO
PL-C__13W/827
PL-C_13W/30/USA
PL-C_13W/35/USA
PL-C_13W/41/USA
PL-C_13W/27/4P
PL-C 13W/830/4P/ALTO
PL=C_13W/35/4P
PL-C_13W/41/4P
PL-S13W/27
PL-S13W/27
PL-S13W/30
PL-S13W/35
PL-S13W/41
PL-S13W/41
PL-S13W/50
----------14786-8
EL/MDT135000K
----EL/O_15_BAW
--EL/A116WG30ALTO
--EL/A/R30
--EL/AR30DIM16ALTO
EL/AR30DIM16ALTO
EL/A R30 Dim 16 ALTO
BR30 16 ALTO
EL/AR30
PL-C_18W/27
PL-C_18W/30
PL-C_18W/35
PL-C_18W/41
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
125
100_cref.qxd
12/13/07
9:44 AM
Page 126
Manufacturers’ Cross Reference Guide (continued)
COMPACT FLUORESCENT LAMPS
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
SYLVANIA
GE
CF18DD/E/827/ECO
CF18DD/E/830/ECO
CF18DD/E/835/ECO
CF18DD/E/841/ECO
CF18DT/E/827/ECO
CF18DT/E/IN/827/ECO
CF18DT/E/IN/830/ECO
CF18DT/E/IN/835/ECO
CF18DT/E/IN/841/ECO
CF19EL/MINITWIST
CF19EL/MINITWIST/2700K
CF19EL/MINITWIST/DAY/BL/1
CF19ELSUPERMINI5KBL
CF19ELSUPERMINI6500BL
CF19ELSUPERMINIRP3
CF20EL/BR40/2700K
CF20EL/BR40/3000K
CF20EL/TWIST
CF23EL/BR40/BL/1
CF23EL/MINITWIST/2700K
CF23EL/PAR38/2700K
CF23EL/PAR38/2700K
CF23EL/PAR38/BL/1
CF23EL/TWIST
CF23ELSUPERMINI6500RP3
CF23RC/BR30/2700K/1 120V
CF26DD/827/ECO
CF26DD/830/ECO
CF26DD/835/ECO
CF26DD/841/ECO
CF26DD/E/827/ECO
CF26DD/E/830/ECO
CF26DD/E/835/ECO
CF26DD/E/841/ECO
CF26DT/E/827/ECO
CF26DT/E/827/ECO/RP/1
CF26DT/E/IN/827/ECO
CF26DT/E/IN/830/ECO
CF26DT/E/IN/835/ECO
CF26DT/E/IN/841/ECO
CF27EL/TWIST
CF27EL/TWIST/2700K
CF28EL/3WAY/TWIST/2700K
CF28EL/3WAY/TWIST/2700K
CF28EL/3WAY/TWIST/830/1
CF28EL/3WAY/TWIST/830/BL/1
CF30EL/CIRC/830/MED
CF30EL/TWIST/2700K
CF32DT/E/827/ECO
CF32DT/E/IN/827/ECO
CF32DT/E/IN/830/ECO
CF32DT/E/IN/835/ECO
CF32DT/E/IN/841/ECO
CF40EL/TWIST/2700K
CF42DT/E/IN/827/ECO
CF42DT/E/IN/830/ECO
CF42DT/E/IN/835/ECO
CF42DT/E/IN/841/ECO
CF4EL/DECO/CANDELABRA/1/BL
CF4EL/DECO/CANDELABRA/2700K
CF57DT/E/IN/830/ECO
CF57DT/E/IN/835/ECO
CF57DT/E/IN/841/ECO
FT18DL/830/ECO
F18DBX/SPX27/4P
F18DBX/SPX30/4P
F18DBX/SPX35/4P
F18DBX/SPX41/4P
F18TBX827/4P/ECO
F18TBX/SPX27/A/4P
F18TBX/SPX30/A/4P
F18TBX/SPX35/A/4P
F18TBX/SPX41/A/4P
--FLE20HT3/2/XL
----FLE20HT3/2/D/2PK
--FLE15/A2/R30
FLE23/A4/R40
FLE21/HLX/8/SW/CD
FLE23/A4/R40
FLE23HT3/2/XL
FLE26/2/PAR38/SW/CD
FLE26/2/PAR38/SW/CD
--FLE27/HLX/8/SW/CD
--GENURA_EL23/R25/SW
F26DBXT4/SPX27
F26DBXT4/SPX30
F26DBXT4/SPX35
F26DBXT4/SPX41
F26DBXT4/SPX27/4P
F26DBXT4/SPX30/4P
F26DBX/SPX35/4P
F26DBX/SPX41/4P
F26TBX827/4P/ECO
F26TBX827/4P/ECO
F26TBX/SPX27/A/4P
F26TBX/SPX30/A/4P
F26TBX/SPX35/A/4P
F26TBX/SPX41/A/4P
FLE26HT3/2/SW/3PK
FLE26HT3/2/SW/3PK
FLE29HLX/2D3/827
FLE29HLX/2D3/827
FEA30CIR/SW/CD
FLE29HLX/2/XL/827
--F32TBX/SPX27/A/4P
F32TBX/SPX30/A/4P
F32TBX/SPX35/A/4P
F32TBX/SPX41/A/4P
FLE42HLX/VT/827
F42TBX/827/A/4P/EOL
F42TBX/830/A/48/EOL
F42TBX/835/A/ECO
F42TBX/841/A/48/EOL
FLE5/2/CAC/827
FLE5/2/CAM/827
F57QBX/830/A/ECO
F57QBX/835/A/ECO
F57QBX/841/A/ECO
F18BX/SPX30
For more complete product information visit www.sylvania.com
126
PHILIPS
PL-C_18W/27/4P
PL-C 18W/830/4P/ALTO
PL-C_18W/35/4P
PL-C_18W/41/4P
PL-T 18W/827/4P/ALTO
PL-T_18W/827/4P
PL-T_18W/30/4P/ALTO
PL-T_18W/35/4P/ALTO
PL-T_18W/41/4P/ALTO
EL/MDT 20
EL/MDT20
----------EL/AR40
Mini-Deco Twister EL/mdT
--EL/MDT27
EL/APAR38
EL/APAR38
--------PL-C_26W/27
PL-C_26W/30
PL-C_26W/35
PL-C_26W/41
PL-C_26W/27/4P
PL-C_26W/30/4P
PL-C_26W/35/4P
PL-C_26W/41/4P
PL-T 26W/827/4P/ALTO
PL-T 26W/827/4P/ALTO
PL-T_26W/827/4P
PL-T_26W/30/4P/ALTO
PL-T_26W/35/4P/ALTO
PL-T_26W/41/4P/ALTO
EL/mdT 27
--EL/TW134-26-18
EL/TW134-26-18
EL/TW134-26-18
EL/TW134-26-18
FC9T5
EL/MDT27
PL-T 32W/827/4P/ALTO
PL-T_32W/827/4P
PL-T_32W/30/4P/ALTP
PL-T_32W/35/4P/ALTO
PL-T_32W/41/4P/ALTO
EL/DT42
PL-T_42W/827/4P
PL-T_42W/30/4P/ALTO
PL-T_42W/835/4P
PL-T_42W/41/4P
EL/MCAN5
EL/A mCan Cand.
PL-T_57W/830/4P/A
PL-T_57W/835/4P/A
PL-T_57W/841/4P/A
PL-L__18W/830
100_cref.qxd
12/13/07
9:44 AM
Page 127
Manufacturers’ Cross Reference (continued)
COMPACT FLUORESCENT LAMPS
SYLVANIA
GE
FT18DL/830/RS/ECO
FT18DL/835/ECO
FT18DL/835/RS/ECO
FT18DL/841/ECO
FT18DL/841/RS/ECO
FT24DL/830/ECO
FT24DL/835/ECO
FT24DL/841/ECO
FT36DL/830/ECO
FT36DL/835/ECO
FT36DL/841/ECO
FT40DL/28W/830/SS/IS/ECO 100V
FT40DL/28W/835/SS/IS/ECO 100V
FT40DL/28W/841/SS/IS/ECO 100V
FT40DL/830/RS/ECO
FT40DL/835/RS/ECO
FT40DL/841/RS/ECO
FT40DL/850/RS/ECO
FT55DL/C/841/ECO
FT80DL/830/ECO
FT80DL/835/ECO
FT80DL/841/ECO
F18BX/SPX30/RS
F18BX/SPX35
F18BX/SPX35/RS
F18BX/SPX41
F18BX/SPX41/RS
F27/24BX/SPX30
F27/24BX/SPX35
F27/24BX/SPX41
F39/36BX/SPX30
F39/36BX/SPX35
F39/36BX/SPX41
------F40/30BX/SPX30_36PK_BULK
F40/30BX/SPX35_36PK_BULK
F40/30BX/SPX41_36PK_BULK
F40/30BX/SPX50RS
---------
PHILIPS
PL-L__18W/830
PL-L__18W/835
PL-L__18W/835
PL-L_18W/41
PL-L_18W/41
PL-L__24W/830
PL-L_24W/835
PL-L_24W/41
PL-L_36W/30
PL-L_36W/35
PL-L_36W/41
------PL-L_40W/30/RS
PL-L_40W/35/RS
PL-L_40W/41/RS
----PL-L_80W/830/4P
PL-L__80W/835/4P
PL-L__80W/841/4P
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
127
100_cref.qxd
12/13/07
9:44 AM
Page 128
Notes:
C
O
M
P
A
C
T
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
128
055_FL_drop.qxd
12/12/07
3:38 PM
Page 129
OSRAM SYLVANIA: THE LEADER IN
ENERGY SAVING FLUORESCENT LAMPS
The fluorescent lamp is an electric discharge device which utilizes a low pressure mercury vapor arc to generate ultra-violet
(plus a little visible) energy. The ultra-violet energy is absorbed by a phosphor coat on the inside of the glass tube
and converted by the phosphor to visible wavelengths; the wavelengths of the light generated are determined by the
composition of the phosphor. In addition to the small amount of mercury vapor, the fluorescent tube contains an
atmosphere of an inert gas, usually argon, krypton, neon, or a mixture of two or more of these gases. The pressure
of the gases contained in the lamp is very low, usually from 2 to 3 torr. Atmospheric pressure is 760 torr.
BULB
PHOSPHOR
CATHODE
EXHAUST TUBE
Usually straight glass tube.
May also be circular or Ushaped.
Coating inside the bulb
transforms ultraviolet radiation into visible light.
Color of light produced
depends on composition
of phosphor.
“Hot cathodes” at each end
of lamp are coated with
emissive materials which
emit electrons. Usually
made of coiled-coil or singlecoil tungsten wire.
Air is exhausted
through this tube during manufacture and
inert gas introduced
into the bulb.
BASE
MERCURY
GAS
STEM PRESS
LEAD-IN WIRES
Several different types
used to connect the
lamp to the electric circuit and to support the
lamp in the lampholder.
A minute quantity of
liquid mercury is
placed in the bulb to
furnish mercury vapor.
Usually argon or a mixture of inert gases at
low pressure. Krypton
is sometimes used.
The lead-in wires have
an air tight seal here
and are made of specific wire to assure about
the same coefficient of
expansion as the glass.
Connect to the base pins
and carry the current to
and from the cathodes
and the mercury arc.
For more complete product information visit www.sylvania.com
F
L
U
O
R
E
S
C
E
N
T
Symbols/Footnotes on page 160-165
129
055_FL_drop.qxd
12/12/07
3:38 PM
Page 130
HOW TO READ PRODUCT INFORMATION - FLUORESCENT
Avg
F
L
U
O
R
E
S
C
E
N
T
CCT
(K)
CRI
Approx Lumens
Initial
Mean
@25°C/77°F Symbols &
(@35˚C/95˚F) Footnotes
Ordering Abbreviation
Pkg
Qty
Avg
Rated
Life (hrs)
Med Bipin 21763
FO32/835XP/ECO
30
24000
3500
85
3000
2850
2,21,31,
35,39,60,70
47.78
Med Bipin 24594
F34CW/SS
Formerly F40CW/SS
30
20000
4200
60
2650
2279
2,10,13,
19,21,42
48
45.5
Mini Bipin 20857
FP54/830/HO
40
20000
3000
85
4450
5000
4228
4750
2,21,26,35,59
96
94
Single Pin 29815
F96T12/CW/SS
15
12000
4200
60
5300
4664
2,15,21
Nominal
Wattage Bulb
Nominal
Length(in)
MOL
(in)
Base
32
T8
48
47.78
34
T12
48
54
T5
60
T12
Nominal Wattage
Bulb
Base
Nominal Length
MOL
Symbols & Footnotes
Ordering Abbreviation
CCT
CRI
Initial & Mean Lumens
Product
Number
|
|
|
|
Design wattage on reference ballast. Actual wattage dependent on ballast.
Describes the shape of the bulb followed by the bulb’s diameter at its widest point. The diameter value is expressed in eighths of
an inch. Ex. T = Tubular, 8 = 8/8 inch = 1 inch. Please see page 134 for bulb illustrations.
Please see page 134 for base illustrations.
The nominal length of linear fluorescent lamps is typically measured from back of lampholder to back of lampholder.
PENTRON® linear lamp, CURVALUME® and Circline lamps are exceptions. The nominal length given for PENTRON linear lamps
is the closest familiar nominal length. CURVALUME lamps are measured from the face of the bases to the outside of the glass
bend. The measurement for Circline lamps is the outside diameter. Values are in inches.
Maximum overall length. The length of the lamp measured in inches.
Most symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and
footnotes are at the end of the fluorescent section.
A text description of the lamp. Please see below for several examples and explanations of some of the codes.
Correlated Color Temperature. The degree of “whiteness” of the light. Expressed in kelvins (K).
Please see page 131 for more information.
Color Rendering Index. A numbering system for rating the relative color rendering quality of a light source compared to a
standard. Please see page 131 for more information.
Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at 40% of
the rated life of the lamp. For longer life lamp such as the OCTRON® XP® lamps, the mean lumens are measured at the same
point in time as they are measured for the standard lamps they replace. Fluorescent lamp lumens are typically measured at
25˚C (77˚F). The lamp lumens are measured at both 25˚C (77˚F) and 35˚C (95˚F) for PENTRON® linear lamps.
How to Read Ordering Abbreviations
FO32/835XP/ECO
F34CW/SS
FP54/830/HO
F96T12/CW/SS
F
O
32
F
34
F
P
54
F
96
T
12
8
35
XP®
ECO®
Fluorescent
OCTRON®
Nominal lamp
wattage
85 CRI
3500K CCT
EXtended
Performance
ECOLOGIC® TCLP passing lamp
CW
SS
Fluorescent
Nominal lamp
wattage
Cool White
phosphor
SUPERSAVER® reduced wattage
lamp
8
30
HO
Fluorescent
PENTRON
Nominal lamp
wattage
85 CRI
3000K CCT
High Output
CW
SS
Fluorescent
96" nominal length
Tubular Shape Bulb
Bulb diameter;
12
⁄8 inch = 1 1⁄2 inches
Cool White phosphor
SUPERSAVER reduced wattage lamp
Lamp Disposal Labeling
The following information appears on the packages of fluorescent lamps. For more information on lamp disposal labeling, see the inside back
cover of this catalog.
Hg
Lamp Contains Mercury
Manage in accordance with disposal laws
See www.lamprecycle.org or 1-866-666-6850
For weight and measurement information, please visit www.sylvania.com
For more complete product information visit www.sylvania.com
130
Symbols/Footnotes on page 160-165
055_FL_drop.qxd
12/12/07
3:38 PM
Page 131
FLUORESCENT LAMP COLORS
COLOR
COLOR
ABBREVIATION
CORRELATED
COLOR
TEMPERATURE(1)
COLOR
RENDERING
INDEX(2)
OCTRON® "800" 2700K
OCTRON XP® "800" 2700K
WARM WHITE DELUXE
WARM WHITE
WARM WHITE PLUS
DESIGNER® 3000K
DESIGNER WARM WHITE
DESIGNER "800" 3000K
DESIGNER WARM WHITE PLUS
OCTRON "700" 3000K
OCTRON XP "700" 3000K
OCTRON "800" 3000K
OCTRON XP "800" 3000K
OCTRON XPS® "800" 3000K
PENTRON® 3000K
GRO-LUX®Aquarium WIDE SPECTRUM
WHITE
DESIGNER 3500K
DESIGNER "800" 3500K
ICETRON® 3500K
PENTRON 3500K
OCTRON "700" 3500K
OCTRON XP "700" 3500K
OCTRON "800" 3500K
OCTRON XP "800" 3500K
OCTRON XPS "800" 3500K
NATURAL WHITE
DESIGNER 4100K
DESIGNER COOL WHITE
DESIGNER "800" 4100K
DESIGNER COOL WHITE PLUS
ICETRON 4100K
OCTRON "700" 4100K
OCTRON XP "700" 4100K
OCTRON "800" 4100K
OCTRON XP "800" 4100K
OCTRON XPS "800" 4100K
PENTRON 4100K
COOL WHITE DELUXE
LITE WHITE
COOL WHITE
COOL WHITE PLUS
ICETRON 5000K
OCTRON "700" 5000K
OCTRON "800" 5000K
OCTRON XP "800" 5000K
OCTRON "900" 5000K
PENTRON 5000K
DESIGN 50®
DAYLIGHT FULL SPECTRUM
DAYLIGHT®
DAYLIGHT 6500
OCTRON "700" 6500K
OCTRON XP "800" 6500K
PENTRON 6500K
DESIGNER 6500K
DAYLIGHT DELUXE
OCTRON SKYWHITE
827
827
WWX
WW
WWP
D30
DWW
D830
DWWP
730
730
830
830
830
830
GRO/AQ/WS
W
D35
D835
835
835
735
735
835
835
835
N
D41
DCW
D841
DCWP
841
741
741
841
841
841
841
CWX
LW
CW
CWP
850
750
850
850
950
580
DSGN50
DAYLIGHTFULL SPECTRUM
DAYLIGHT
DAYLIGHT6500V
765
865
865
865
DX
SKYWHITE
2700
2700
2900
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3400
3450
3500
3500
3500
3500
3500
3500
3500
3500
3500
3600
4100
4100
4100
4100
4100
4100
4100
4100
4100
4100
4100
4100
4150
4200
4100
5000
5000
5000
5000
5000
5000
5000
5000
6500
6500
6500
6500
6500
6500
6500
8000
85
85
82
52
70
70
70
80
80
75
78
82
85
85
85
89
57
70
80
80
85
75
78
82
85
86
86
70
70
80
80
80
75
78
82
85
86
85
87
48
60
70
80
75
80
85
90
85
90
90
76
80
75
85
85
80
88
88
For more complete product information visit www.sylvania.com
F
L
U
O
R
E
S
C
E
N
T
Symbols/Footnotes on page 160-165
131
055_FL_drop.qxd
12/12/07
3:38 PM
Page 132
FLUORESCENT COMPETITIVE GUIDES
NOTE: These tables are intended only as guides and may represent another lamp company’s most similar product or product family rather
than an identical match. Individual manufacturer’s performance values should be consulted. Environmental conditions, ballast type, and other
auxiliary equipment may affect lamp performance.
FLUORESCENT BRAND NAMES
SYLVANIA
F
L
U
O
R
E
S
C
E
N
T
GE*
PHILIPS**
CURVALUME® (FB)
MOD-U-LINE (U)
U-Bent (FB)
CWX
Home Light Everywhere (HL Everywhere)
®
DESIGN 50 (DSGN50)
Chroma 50 (C50)
Colortone 50 (C50)
DESIGNER® Series
Specification Series (SP)
SPEC or TL700
DESIGNER 800 Series
Specification Series (SPX)
Ultralume or TL800
DESIGNER Cool White
SP41
Home Light Cool (HL Cool)
DESIGNER Cool White PLUS
SPX41
41U
DESIGNER Warm White
Kitchen and Bath ULTRA (70 CRI)
SPEC30
DESIGNER Warm White PLUS (DWWP)
Kitchen and Bath ULTRA (80 CRI)
Home Light WX (HL WX)
DESIGNER 700, 3500K (D35)
SP35
Home Light Warm (HL Warm)
®
®
ECOLOGIC
(ECO )
Ecolux (ECO)
ALTO
GRO-LUX®
Gro & Sho/Plant & Aquarium/Terrarium
Agro-Lite (AGRO)
ICETRON®
----OCTRON®
T8 (was Trimline)
TL70/TL80
OCTRON 700 XP™ ECO
SP Ecolux XL T8 Lamps with Starcoat
TL700 PLUS ALTO
OCTRON 800 XP ECO
SPX Ecolux XL T8 Lamps with Starcoat
TL800 PLUS ALTO
OCTRON 800 XPS ECO
----OCTRON 950
--TL950
PENTRON®
T5 Starcoat
SILHOUETTE™
----QL (similar to ICETRON, but not interchangeable)
SAFELINE®
covRguard
--SUN STICK®
SUN (Sunshine)
C50
SUPERSAVER® (SS)
Watt-Miser (WM)
Econ-o-Watt (EW)
HO (800mA)
HO (800mA)
HO (800mA)
VHO (1500mA)
1500 (1500mA) & Power Grove
VHO (1500mA) (was SHO)
VHO/LT
T10/1500MA
VHO-0
®
XP
XL
Plus
XPS®
Advantage
* Trademarks or registered trademarks of General Electric Company ** Trademarks or registered trademarks of Philips
FLUORESCENT COLOR CROSS REFERENCE
SYLVANIA
GE
PHILIPS
SYLVANIA
GE
PHILIPS
CW
CWX
D
DX
DSGN50
DSGN50
DCW, D41
DCWP
DWW, D30
DWWP, D830
D35
GRO/AQ
GRO/WS/AQ
LW
N
SUN STICK
WW
D30
D35
CW
CW
CWX, HL Everywhere
D
DX
50
C50
HL Cool
U41
SPEC30
HL WX
HL Warm
AGRO
D41
SP41
SP65
SPX30
SPX35
SPX41
Spec 41
D
DX
C50
SGN
SP41
SPX41
KB / 70 CRI, SP30
KB / 82 CRI, SPX30
SP35
PL/AQ
LW
N
SUN
WW
SP30
SP35
For more complete product information visit www.sylvania.com
132
LW
N
C50
WW
Spec 30
Spec 35
D830
D835
D841
D865
730
735
741
750
765
827
830
835
841
850
865
950
SP30
SP35
SP41
SP50
SP65
SPX27
SPX30
SPX35
SPX41
SPX50
SPX65
30U
35U
41U
730
735
741
750
27
30, 830
35, 835
41, 841
50, 850
865
950
Symbols/Footnotes on page 160-165
055_FL_drop.qxd
12/12/07
3:38 PM
Page 133
FLUORESCENT COMPETITIVE GUIDES (continued)
FLUORESCENT ELECTRICAL INTERCHANGEABILITY
SYLVANIA
GE
PHILIPS
F24"T8/CW/4
F26"T8/CW/4
F28"T8/CW/4
F30"T8/CW/4
F34CW/WM
F40CW/WM
F96T12/CW/WM
F40/SP41/U/6
F40CW/U/6/WM (new F34CW/U/6/WM)
T8 (was Trimline)
T8 SP
T8 SPX
F17T8/SP(or SPX)…
F25T8/SP(or SPX)…
F32T8/SP(or SPX)…
F32T8/XL/SP (or SPX)
--F32T8/SP…/IS/WM/ECO
----F40T8/SP… (or SPX)
--F96T8/SP… (or SPX)
F96T8/XL.SP...
F96T8/XL/SPX...
F96T8/SP…/WM
------F96T8/SP (or SPX)…/HO
F25T12/SP… (for T8 electronic ballasts)
----F31T8/SPX…/U
--F32T8/SP(or SPX)…/U6
--------F14/T5/8..
F21/T5/8..
F28/T5/8..
F35/T5/8..
F24/T5/8../HO
F39/T5/8../HO
F54/T5/8../HO
F80/T5/8../HO
F40T17/CW/IS
F96T17/…
HO (800mA)
F96T12/…/HO/CT
1500 or PG17 (both 1500mA)
T10, 1500-0 (both1500mA)
F15T8/CW/24
F16T8/CW/26
F17T8/CW/28
F18T8/CW/30
F34CW/EW
F40CW/EW
F96T12/CW/EW
FB40/SPEC41/6
FB40/CW/6/EW (new F34/CW/6/EW)
TL70/TL80
TL70
TL80
F17T8/TL…
F25T8/TL…
F32T8/TL…
F32T8/TL...PLUS
F32T8/ADV
F32T8/ADV8.../EW
--F32T8/ADV8…/XEW/ALTO
F40T8/TL
--F96T8/TL…
------F48T8/TL…/HO
F60T8/TL…/HO
F72T8/TL…/HO
F96T8/TL…/HO
----------FB32T8/TL…/6
--------F14T5/8..
F21T5/8..
F28T5/8..
F35T5/8..
F24T5/8../HO
F39T5/8../HO
F54T5/8../HO
F80T5/8../HO
----HO (800mA)
F96T12/…/HO-0
VHO (1500mA)
VHO-0 (1500mA)
------EL23/R25/… (Genura™)
-------
--------QL55W/… (QL)
QL85W/… (QL)
QL165W/…(QL)
Linear Lamps
F18T8/CW/K/23
F18T8/CW/K/26
F18T8/CW/K/28
F18T8/CW/K/30
F34CW/SS
Formerly known as F40CW/SS
F96T12/CW/SS
FB40/D41/6
FB40/CW/6/SS (new FB34/CW/6/SS)
OCTRON®
OCTRON 700 Series
OCTRON 800 Series
FO17…
FO25…
FO32…
FO32/...XP®
FO32/.../XPS®/ECO®
FO30…XP/SS/ECO
FO28/8..XP/SS/ECO
FO32/25W/8…XP/SS/ECO
FO40…
FO72…
FO96…
FO96/7…XP/ECO
FO96/8…XP/ECO
FO96/8...XP/SS/ECO
------FO96…/HO/ECO
--FBO16…
FBO24…
FBO31…
FBO31…XP
FBO32…
FBO32…XP
FBO31/...XPS/ECO
FBO32/...XPS/ECO
FBO32/8..XP/SS/ECO
FP14/8..
FP21/8..
FP28/8..
FP35/8..
FP24/8../HO
FP39/8../HO
FP54/8../HO
FP80/8../HO
----HO (800mA)
F96T12/…/HO/COLDTEMP
VHO (1500mA)
VHO/LT (1500mA)
F
L
U
O
R
E
S
C
E
N
T
Induction Lamps
ICE 70/8... (ICETRON®)
ICE 100/8… (ICETRON)
ICE 150/8… (ICETRON)
---------
For a more complete manufacturers' cross reference, please see that section of this catalog or visit the electronic catalog at www.sylvania.com.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 160-165
133
055_FL_drop.qxd
12/12/07
3:38 PM
Page 134
FLUORESCENT LAMPS
F
L
U
O
R
E
S
C
E
N
T
The bulb shape and size of a fluorescent lamp
are expressed by means of a code consisting
of the letter “T” (which designates that the
bulb is “tubular” in shape) followed by a
number that expresses the diameter in eighths
of an inch. Diameters range from T2 (1⁄4 inch)
to T17 (2 1⁄8 inch). In nominal overall length,
linear fluorescent lamps range from 6 to 96
inches. The nominal length is measured from
back of lamp holder to back of lamp holder.
For example, the actual overall length of the
40-watt rapid start T12 lamp with a nominal
length of 48 inches is 47 3⁄4 inches. The
nominal length given for PENTRON® linear
lamps is the closest familiar nominal length.
CURVALUME® U-shaped fluorescent lamps are
available as OCTRON® T8 lamps with leg
spacings of 1 5⁄8 inches and 6 inches and as
rapid start T12 lamps with 6 spacings of 6
inches. The leg spacing is measured from the
center of one leg to the center of the other leg.
The overall length of the CURVALUME lamps
is measured from the face of the bases to the
outside of the glass bend. Circline lamps,
which are circular in shape, are available as
T9 lamps with outside diameters of 6 1⁄2, 8,
12 and 16 inches as well as PENTRON T5
lamps with outside diameters of 8.85 and
11.77 inches.
HIGH OUTPUT AND VERY HIGH OUTPUT
T2 MINIATURE
T2 Axial Base (2/8" Diameter)
OCTRON T8 Recessed Double Contact (1" diameter)
PREHEAT, RAPID START
Preheat T5 Miniature Bipin (5/8" diameter
PENTRON T5 Miniature Bipin (5/8" diameter)
T12 Recessed Double Contact (1-1/2" diameter)
T8 Medium Bipin (1" diameter)
T14-1/2 Recessed Double Contact (1-13/16" diameter)
Germicidal Compact Fluorescent
INSTANT START
OCTRON T8 Medium Bipin (1" diameter)
Rapid Start or Instant Start operation
T6 Single Pin (3/4" diameter)
T12 Medium Bipin (1-1/2" diameter)
T8 Single Pin (1" diameter)
OCTRON T8 Single Pin (1" diameter)
T12 Single Pin (1-1/2" diameter)
U-Shaped T12
(1-1/2" diameter)
6” leg spacing
OCTRON T8 U-Shaped
with 1 5/8" leg spacing
(1" diameter)
CIRCLINE 4-Pin T-9
(6-1/2", 8", 12", 16"
outside diameters)
G23
OCTRON T8 U-Shaped
with 6" leg spacing
(1" diameter)
PENTRON CIRCLINE 4Pin T5 (8.85" & 11.77"
outside diameters)
®
ICETRON
Germicidal T5 Bipin
2G11
Germicidal Single End
Germicidal Single Pin
Germicidal T8 Bipin
BASES
For linear Preheat and Rapid Start Lamps, four electrical
contacts are required, two at each end of the lamp. This is
accomplished in the standard line of lamps by the use of a
miniature bipin base for T5 lamps and a medium bipin for T8
and T12 lamps. The OCTRON® T8 medium bipin lamps may
also be operated as instant start lamps with the proper
wiring and ballasts. When operating OCTRON bipin lamps
with instant start ballasts, the two contacts in the lamp
holder are shorted together and connected to the single
circuit in the ballast. In Circline lamps, the cathodes are
connected to a four-pin base located between the junction of
the two ends of the lamp. High Output (HO) and Very High
Output (VHO) lamps have recessed double contact (RDC)
type bases. Slimline Instant Start lamps require only two
electrical contacts, one on each lamp end and have single
pin bases.
SINGLE PIN
Single Pin for
T6 Slimline
Single Pin for T8 Slimline
& OCTRON
Single Pin for
T12 Slimline
BIPIN
Miniature Bipin for T5
Preheat & PENTRON®
Recessed Double Contact
for OCTRON T8 HO
Miniature Bipin for T8
Preheat & OCTRON
Medium Bipin for T12
Axial T2 Subminiature
Recessed Double Contact
for T12 HO & VHO
Germicidal Compact Fluorescent
4-pin for
PENTRON Circline
ICETRON® Mounting Brackets
GX 23
2 G 11
For more complete product information visit www.sylvania.com
134
Germicidal Single End
Germicidal Single Pin
4-pin for T9 Circline
OCTRON T8 & T12 Rapid Start CURVALUME
Germicidal T5 Bipin
Germicidal T8 Bipin
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
Page 135
T8 Med Bipin
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® lamps are T8 fluorescent lamps designed to be operated on dedicated magnetic rapid start or electronic instant start or programmed rapid start (also
known as programmed start) ballasts. For details on various lamp/ballast system combinations, please refer to the Systems Performance Guide in the "SYLVANIA QUICKTRONIC® Ballast Technology and Specification Guide".
OCTRON® 800 XPS® Lamps
40
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Med Bipin
21680
30
21697
21681
21660
21659
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
17
24
T8
23.78
FO32/830/XPS/ECO
FO32/835/XPS/ECO
FO32/841/XPS/ECO
FO32/850/XPS/ECO
FO32/865/XPS/ECO
30
30
30
30
Avg Rated Life
@3hrs/start CCT
(@12hrs/start) (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
36000
(42000)
3000
85
36000
(42000)
3500
36000
(42000)
4100
36000
(42000)
5000
36000
(42000)
6500
3100
2945
19,31,33,48,
52,76,94
85
3100
2945
19,31,33,48,
52,76,94
85
3100
2945
19,31,33,48,
52,76,94
80
3000
2850
19,31,33,
48,52,76,94
80
2900
2750
19,31,33,
48,52,76,94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22150
30
30000
85
FO17/830/XPS/ECO
|
|
|
3000
1400
1330
|
|
|
31,33,48,52,
76,93,94
22151
FO17/835/XPS/ECO
30
30000
3500
85
1400
1330
31,33,48,52,
76,93,94
22152
FO17/841/XPS/ECO
30
30000
4100
85
1400
1330
31,33,48,52,
76,93,94
25
T8
36
35.78
Med Bipin
22153
FO25/830/XPS/ECO
30
30000
3000
85
2200
2090
31,33,48,52,
76,93,94
22154
FO25/835/XPS/ECO
30
30000
3500
85
2200
2090
31,33,48,52,
76,93,94
22155
FO25/841/XPS/ECO
30
30000
4100
85
2200
2090
31,33,48,52,
76,93,94
OCTRON® 800 XP® 4 Foot SUPERSAVER® Lamps
40
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
25
48
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Med Bipin
22232
30
22233
22234
22235
28
T8
48
47.78
Med Bipin
22177
22178
22179
22184
For more complete product information visit www.sylvania.com
FO32/25W/830/XP/SS/ECO
FO32/25W/835/XP/SS/ECO
FO32/25W/841/XP/SS/ECO
FO32/25W/850/XP/SS/ECO
FO28/830/XP/SS/ECO
FO28/835/XP/SS/ECO
FO28/841/XP/SS/ECO
FO28/850XP/SS/ECO
30
30
30
30
30
30
30
Avg Rated Life
@3hrs/start CCT
(@12hrs/start) (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
36000
(42000)
3000
85
36000
(42000)
3500
36000
(42000)
4100
36000
(42000)
5000
36000
(42000)
3000
36000
(42000)
3500
36000
(42000)
4100
36000
(42000)
5000
2475
2350
|
|
|
9,16,17,18,
20,31,33,76,94
85
2475
2350
9,16,17,18,
20,31,33,76,94
85
2475
2350
9,16,17,18,
20,31,33,76,94
85
2300
2185
9,16,17,18,
20,31,33,76,94
85
2725
2590
9,16,20,23,
31,33,44,76,94,95
85
2725
2590
9,16,20,23,
31,33,44,76,94,95
85
2725
2590
9,16,20,23,
31,33,44,76,94,95
80
2600
2470
9,16,20,
23,31,33,76,94,95
Symbols/Footnotes on page 160-165
135
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
Page 136
T8 Med Bipin
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® 800 XP® 4 Foot SUPERSAVER® Lamps
40
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
30
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Med Bipin
22063
30
22060
22062
22202
FO30/830/XP/SS/ECO
FO30/835/XP/SS/ECO
FO30/841/XP/SS/ECO
FO30/850/XP/SS/ECO
30
30
30
Avg Rated Life
@3hrs/start CCT
(@12hrs/start) (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
36000
(42000)
3000
85
36000
(42000)
3500
36000
(42000)
4100
36000
(42000)
5000
2850
2710
|
|
|
9,16,20,23,
31,33,76,94,95
85
2850
2710
9,16,20,23,
31,33,76,94,95
85
2850
2710
9,16,20,23,
31,33,76,87,95
85
2800
2660
9,16,20,23,
31,33,76,94,95
OCTRON® 800 XP® Lamps
F
L
U
O
R
E
S
C
E
N
T
40
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Med Bipin
22039
30
21759
21763
21767
22026
21720
22594
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
17
24
T8
23.78
FO32/827/XP/ECO
FO32/830/XP/ECO
FO32/835/XP/ECO
FO32/841/XP/ECO
FO32/850/XP/ECO
FO32/865/XP/ECO
FO32/SKYWHITE/XP/ECO
30
30
30
30
30
30
Avg Rated Life
@3hrs/start CCT
(@12hrs/start) (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
36000
(42000)
2700
85
36000
(42000)
3000
36000
(42000)
3500
36000
(42000)
4100
36000
(42000)
5000
36000
(42000)
6500
36000
(42000)
8000
3000
2850
20,31,33,48,
52,76,94
85
3000
2850
20,31,33,48,
52,76,94
85
3000
2850
20,31,33,48,
52,76,94
85
3000
2850
20,31,33,48,
52,76,94
85
3000
2850
20,31,33,48,
52,76,94
85
2850
2708
20,31,33,48,
52,76,94
88
2650
2518
20,31,33,48,
52,76,94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21587
30
24000
85
FO17/827/XP/ECO
|
|
|
2700
1375
1305
|
|
|
31,33,44,48,
52,76,87
21785
FO17/830/XP/ECO
30
24000
3000
85
1375
1305
31,33,44,48,
52,76,87
21778
FO17/835/XP/ECO
30
24000
3500
85
1375
1305
31,33,44,48,
52,76,87
21907
FO17/841/XP/ECO
30
24000
4100
85
1375
1305
31,33,44,48,
52,76,87
22193
FO17/850/XP/ECO
30
24000
5000
85
1375
1305
31,33,44,48,
52,76,87
21718
FO17/865/XP/ECO
30
24000
6500
85
1250
1188
31,33,44,48,
52,76,87
25
T8
36
35.78
Med Bipin
21586
FO25/827/XP/ECO
30
24000
2700
85
2175
2065
31,33,44,48,
52,76,87
21910
FO25/830/XP/ECO
30
24000
3000
85
2175
2065
31,33,44,48,
52,76,87
21776
FO25/835/XP/ECO
30
24000
3500
85
2175
2065
31,33,44,48,
52,76,87
21774
FO25/841/XP/ECO
30
24000
4100
85
2175
2065
31,33,44,48,
52,76,87
For more complete product information visit www.sylvania.com
136
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
Page 137
T8 Med Bipin
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® 800 XP® Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
25
36
T8
35.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22194
30
24000
85
FO25/850/XP/ECO
5000
2175
2065
|
|
|
31,33,44,48,
52,76,87
21719
FO25/865/XP/ECO
30
24000
6500
85
2000
1900
31,33,44,48,
52,76,87
40
T8
60
59.61
Med Bipin
21912
FO40/830/XP/ECO
30
24000
3000
85
3750
3560
31,33,44,48,
52,76,87
21911
FO40/835/XP/ECO
30
24000
3500
85
3750
3560
31,33,44,48,
52,76,87
21916
FO40/841/XP/ECO
30
24000
4100
85
3750
3560
31,33,44,48,
52,76,87
21721
FO40/865/XP/ECO
30
24000
6500
85
3650
3468
31,33,44,48,
52,76,87
®
®
OCTRON 700 XP Lamps
40
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Med Bipin
21711
30
22044
21712
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
17
24
T8
23.78
FO32/730/XP/ECO
FO32/735/XP/ECO
FO32/741/XP/ECO
30
30
Avg Rated Life
@3hrs/start CCT
(@12hrs/start) (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
36000
(42000)
3000
78
36000
(42000)
3500
36000
(42000)
4100
2850
2705
31,33,44,
48,52,76,94
78
2850
2705
31,33,44,
48,52,76,94
78
2850
2705
31,33,44,
48,52,76,94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21699
30
24000
78
FO17/735/XP/ECO
|
|
|
3500
1325
1255
|
|
|
31,33,44,48,
52,76,87
21637
FO17/741/XP/ECO
30
24000
4100
78
1325
1255
31,33,44,48,
52,76,87
25
T8
36
35.78
Med Bipin
21698
FO25/735/XP/ECO
30
24000
3500
78
2050
1945
31,33,44,48,
52,76,87
21639
FO25/741/XP/ECO
30
24000
4100
78
2050
1945
31,33,44,48,
52,76,87
OCTRON® 800 Lamps
40
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Med Bipin
21777
30
21779
21781
22143
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
17
24
T8
23.78
FO32/830/ECO
FO32/835/ECO
FO32/841/ECO
FO32/850/ECO
30
30
30
Avg Rated Life
@3hrs/start CCT
(@12hrs/start) (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
30000
(35000)
3000
85
30000
(35000)
3500
30000
(35000)
4100
30000
(35000)
5000
2950
2802
21,31,33,
48,52,76,94
85
2950
2802
21,31,33,
48,52,76,94
85
2950
2802
21,31,33,
48,52,76,94
80
2800
2660
21,31,33,
48,52,76,94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22135
30
20000
82
FO17/830/ECO
|
|
|
3000
1350
1240
|
|
|
31,33,35,48,
52,76
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 160-165
137
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
Page 138
T8 Med Bipin
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® 800 Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
17
24
T8
23.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22136
30
20000
82
FO17/835/ECO
3500
1350
1240
|
|
|
31,33,35,48,
52,76
22137
FO17/841/ECO
30
20000
4100
82
1350
1240
31,33,35,48,
52,76
25
T8
36
35.78
Med Bipin
22138
FO25/830/ECO
30
20000
3000
82
2150
1975
31,33,35,48,
52,76
22139
FO25/835/ECO
30
20000
3500
82
2150
1975
31,33,35,48,
52,76
22140
F
L
U
O
R
E
S
C
E
N
T
FO25/841/ECO
30
20000
4100
82
2150
1975
31,33,35,48,
52,76
40
T8
60
59.61
Med Bipin
22144
FO40/830/ECO
30
20000
3000
82
3650
3473
31,33,35,48,
52,76
22145
FO40/835/ECO
30
20000
3500
82
3650
3473
31,33,35,48,
52,76
22146
FO40/841/ECO
30
20000
4100
82
3650
3473
31,33,35,48,
52,76
OCTRON® 700 Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21997
30
25000
78
FO32/730/ECO
3000
2800
2520
|
|
|
31,33,48,
52,76, 119
21998
FO32/735/ECO
30
25000
3500
78
2800
2520
31,33,48,
52,76, 119
21678
FO32/735/SL
30
25000
3500
78
2716
2444
31,33,52,96,
98,119
22181
FO32/741/ECO/CVP
12
25000
4100
78
2800
2520
31,33,48,
52,76, 119
21547
FO32/741/ECO/SL
30
25000
4100
78
2716
2444
31,33,52,
76,96,98,119
21999
FO32/741/ECO
30
25000
4100
78
2800
2520
31,33,48,
52,76, 119
22141
FO32/750/ECO
30
25000
5000
78
2650
2385
31,33,48,
52,76, 119
22175
FO32/765/ECO
30
25000
6500
78
2700
2430
31,33,48,
52,76, 119
14
T8
18
17.91
Med Bipin
21666
FO13/735/ECO
30
20000
3500
75
830
745
31,33,35,48,
52,76
21667
FO13/741/ECO
30
20000
4100
75
830
745
31,33,35,48,
52,76
17
T8
24
23.78
Med Bipin
21918
FO17/730/ECO
30
20000
3000
75
1300
1170
31,33,35,48,
52,76
21769
FO17/735/ECO
30
20000
3500
75
1300
1170
31,33,35,48,
52,76
21770
FO17/741/ECO
30
20000
4100
75
1300
1170
31,33,35,48,
52,76
25
T8
36
35.78
Med Bipin
21937
FO25/730/ECO
30
20000
3000
75
1950
1755
31,33,35,48,
52,76
For more complete product information visit www.sylvania.com
138
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
T8 Med Bipin
Page 139
T8 Single Pin
T8 RDC
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® 700 Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
25
36
T8
35.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21941
30
20000
75
FO25/735/ECO
3500
1950
1755
|
|
|
31,33,35,48,
52,76
21942
FO25/741/ECO
30
20000
4100
75
1950
1755
31,33,35,48,
52,76
40
T8
60
59.61
Med Bipin
22102
FO40/730/ECO
30
20000
3000
75
3500
3150
31,33,35,48,
52,76
22103
FO40/735/ECO
30
20000
3500
75
3500
3150
31,33,35,48,
52,76
22104
FO40/741/ECO
30
20000
4100
75
3500
3150
31,33,35,48,
52,76
OCTRON® 800 XP® 8 Foot SUPERSAVER® Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
55
96
T8
94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Single Pin
22100
24
18000
85
FO96/835/XP/SS/ECO
3500
5700
5415
|
|
|
7,31,33,76,
85
22101
FO96/841/XP/SS/ECO
24
18000
4100
85
5700
5415
7,31,33,76,
85
OCTRON® 800 XP® 8 Foot Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
59
96
T8
94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Single Pin
22036
24
18000
85
FO96/830/XP/ECO
3000
6100
5795
|
|
|
31,33,44,48,
76,85
22034
FO96/835/XP/ECO
24
18000
3500
85
6100
5795
31,33,44,48,
76,85
22032
FO96/841/XP/ECO
24
18000
4100
85
6100
5795
31,33,44,48,
76,85
22174
FO96/850/XP/ECO
24
18000
5000
85
6100
5795
31,33,44,48,
76,85
OCTRON® 800 8 Foot Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
59
96
94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Single Pin
22147
24
15000
82
FO96/830/ECO
3000
5900
5428
|
|
|
10,31,33,
48,76
22148
FO96/835/ECO
24
15000
3500
82
5900
5428
10,31,33,
48,76
22149
FO96/841/ECO
24
15000
4100
82
5900
5428
10,31,33,
48,76
22173
FO96/850/ECO
24
15000
5000
80
5900
5428
10,31,33,
48,76
86
T8
96
93.91
Recessed DC
For more complete product information visit www.sylvania.com
22206
FO96/835/HO/ECO
24
18000
3500
85
8200
7710
31,33,48,76
22207
FO96/841/HO/ECO
24
18000
4100
85
8200
7710
31,33,48,76
Symbols/Footnotes on page 160-165
139
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
T8 Single Pin
Page 140
T8 RDC
T8 U-Shaped 1-5/8"
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® 700 8 Foot Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
59
96
T8
94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Single Pin
22030
24
15000
75
FO96/730/ECO
3000
5700
5130
|
|
|
31,33,48,
76,84
21737
FO96/735/ECO
24
15000
3500
75
5700
5130
31,33,48,
76,84
21736
FO96/741/ECO
24
15000
4100
75
5700
5130
31,33,48,
76,84
86
T8
96
93.91
Recessed DC
22204
FO96/735/HO/ECO
24
18000
3500
78
8000
7520
31,33,48,
76
22205
F
L
U
O
R
E
S
C
E
N
T
FO96/741/HO/ECO
24
18000
4100
78
8000
7520
31,33,48,
76
OCTRON® 800 XP® SUPERSAVER® CURVALUME® U-SHAPED Lamps - 1 5/8” Leg Spacing
The OCTRON® CURVALUME® lamps are made to the same color standards and may be used in conjunction with other SYLVANIA OCTRON lamps to meet the
needs of lighting installations where OCTRON T8 systems are used. Since CURVALUME and linear OCTRON lamps of the same/similar wattages operate on the
same ballasts, the types of ballasts used in an installation can be minimized. When OCTRON FBO31 lamps are used in 2X2 luminaires, the 2X2 luminaire can
deliver light levels similar to 2X4 luminaires with the same number of linear OCTRON lamps. The nominal length of the CURVALUME lamp is measured from the
base face to the outside of the glass bend.
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
29
22.5
T8
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22195
15
24000
85
FBO29/830XP/SS/ECO
3000
2775
2636
|
|
|
9,31,33,44,
54,76,87,95
22196
FBO29/835XP/SS/ECO
15
24000
3500
85
2775
2636
9,31,33,44,
54,76,87,95
22197
FBO29/841XP/SS/ECO
15
24000
4100
85
2775
2636
9,31,33,44,
54,76,87,95
OCTRON® 800 XP® CURVALUME® U-SHAPED Lamps - 1 5/8” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
31
22.5
T8
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21693
15
24000
85
FBO31/830/XP/ECO
3000
2775
2636
|
|
|
31,33,44,
48,52,54,55,76,87
21695
FBO31/835/XP/ECO
15
24000
3500
85
2775
2636
31,33,44,
48,52,54,55,76,87
21696
FBO31/841/XP/ECO
15
24000
4100
85
2775
2636
31,33,44,
48,52,54,55,76,87
OCTRON® CURVALUME® U-SHAPED Lamps - 1 5/8” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
31
22.5
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21877
15
20000
82
FBO31/830
3000
2725
2507
|
|
|
31,33,35,48,52,54,
55
21878
FBO31/835
15
20000
3500
82
2725
2507
31,33,35,48,52,54,
55
21879
FBO31/841
15
20000
4100
82
2725
2507
31,33,35,48,52,54,
55
16
T8
10.5
10.60
Med Bipin
21834
FBO16/830
15
20000
3000
82
1125
1035
31,33,35,48,52,54,
55
21835
FBO16/835
15
20000
3500
82
1125
1035
31,33,35,48,52,54,
55
For more complete product information visit www.sylvania.com
140
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
T8 U-Shaped 1-5/8"
Page 141
T8 U-Shaped 6"
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® CURVALUME® U-SHAPED Lamps - 1 5/8” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
16
10.5
T8
10.60
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21836
15
20000
82
FBO16/841
4100
1125
1035
|
|
|
31,33,35,48,52,54,
55
24
T8
16.5
16.6
Med Bipin
21874
FBO24/830
15
20000
3000
82
1925
1771
31,33,35,48,52,54,
55
21875
FBO24/835
15
20000
3500
82
1925
1771
31,33,35,48,52,54,
55
21876
FBO24/841
15
20000
4100
82
1925
1771
31,33,35,48,52,54,
55
OCTRON® 800 XP® SUPERSAVER® CURVALUME® U-SHAPED Lamps - 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
30
22.5
T8
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22170
16
24000
85
FBO30/830XP/6/SS/ECO
3000
2800
2660
|
|
|
9,31,33,44,
54,76,87,95
22171
FBO30/835XP/6/SS/ECO
16
24000
3500
85
2800
2660
9,31,33,44,
54,76,87,95
22172
FBO30/841XP/6/SS/ECO
16
24000
4100
85
2800
2660
9,31,33,44,
54,76,87,95
OCTRON® 800 XP® CURVALUME® U-SHAPED Lamps - 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
22.5
T8
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22054
16
24000
85
FBO32/830XP/6/ECO
3000
2900
2755
|
|
|
31,33,44,48,
52,54,76,87
22055
FBO32/835XP/6/ECO
16
24000
3500
85
2900
2755
31,33,44,48,
52,54,76,87
22057
FBO32/841XP/6/ECO
16
24000
4100
85
2900
2755
31,33,44,48,
52,54,76,87
OCTRON® 800 CURVALUME® U-SHAPED Lamps - 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
22.5
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21663
16
20000
82
FBO32/830/6/ECO
3000
2850
2622
|
|
|
31,33,35,48,
52,54,76
21670
FBO32/835/6/ECO
16
20000
3500
82
2850
2622
31,33,35,48,
52,54,76
21671
FBO32/841/6/ECO
16
20000
4100
82
2850
2622
31,33,35,48,
52,54,76
OCTRON® 700 CURVALUME® U-SHAPED Lamps - 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
22.5
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22046
16
20000
75
FBO32/730/6/ECO
3000
2750
2475
|
|
|
31,33,35,
48,52,54,76
22051
FBO32/735/6/ECO
16
20000
3500
75
2750
2475
31,33,35,
48,52,54,76
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 160-165
141
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
T8 U-Shaped 6"
Page 142
T8 Med Bipin
T8 U-Shaped 1-5/8"
OCTRON® AND OCTRON® CURVALUME® FLUORESCENT LAMPS
OCTRON® 700 CURVALUME® U-SHAPED Lamps - 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
22.5
T8
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
22052
16
20000
75
FBO32/741/6/ECO
4100
2750
2475
|
|
|
31,33,35,
48,52,54,76
22053
FBO32/750/6/ECO
16
20000
5000
75
2625
2363
31,33,35,
48,52,54,76
OCTRON® 5000K And 6500K for Displays, Signage and Backlighting
F
L
U
O
R
E
S
C
E
N
T
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
14
18
T8
17.91
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21731
30
24000
85
FO13/865XP/ECO
6500
850
805
|
|
|
31,33,44,48,
52,76,87
15
T8
20
19.78
Med Bipin
21868
FO14/950/20in
30
20000
5000
90
750
638
21716
FO14/865/XP/ECO
30
24000
6500
85
1000
950
31,33,35,48,52
31,33,44,48,
52,76,87
16
T8
10.5
10.60
Med Bipin
21726
FBO16/865XP
15
24000
6500
85
1125
1069
31,33,44,48,52,54,
55,87
17
T8
24
23.78
Med Bipin
21871
FO17/950/24in
30
20000
5000
90
800
680
21718
FO17/865/XP/ECO
30
24000
6500
85
1250
1188
31,33,35,48,52
31,33,44,48,
52,76,87
21
T8
30
29.78
Med Bipin
21869
FO21/950/30in
30
20000
5000
90
1000
850
21730
FO21/865/XP/ECO
30
24000
6500
85
1600
1520
31,33,35,48,52
31,33,44,48,
52,76,87
25
T8
36
35.78
Med Bipin
21872
FO25/950/36in
30
20000
5000
90
1250
1063
21719
FO25/865/XP/ECO
30
24000
6500
85
2000
1900
31,33,35,48,52
31,33,44,48,
52,76,87
28
T8
40
39.78
Med Bipin
32
T8
48
47.78
Med Bipin
40
T8
60
59.61
Med Bipin
21870
FO28/950/40in
30
20000
5000
90
1400
1190
31,33,35,48,52
21880
FO32/950/48in
30
25000
5000
90
1800
1530
31,33,48,52
21720
FO32/865/XP/ECO
30
36000
()
6500
85
2850
2708
20,31,33,48,
52,76,94
21873
FO40/950/60in
30
20000
5000
90
2200
1870
21721
FO40/865/XP/ECO
30
24000
6500
85
3650
3468
31,33,35,48,52
31,33,44,48,
52,76,87
OCTRON® Specialty
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Med Bipin
21961
10
25000
For more complete product information visit www.sylvania.com
142
FO32/GOLD
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
1700
1530
|
|
|
31,33,35,43,48,52
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
Page 143
T5 Mini Bipin
PENTRON® T5 FLUORESCENT LAMPS
PENTRON® T5 lamps are designed to operate on dedicated electronic programmed rapid start (also know as programmed start) ballasts only. These lamps are
globally standardized and are designed to operate with their peak light output at 35°C (95°F) ambient temperature. For comparison purposes and to accommodate existing lamp measurement standards, ratings are given at both 25°C (77°F) and 35°C (95°F). The new lamp dimensions allow for innovative fixture
designs and improved fixture performance
PENTRON® High Performance T5 Lamps
45
Avg
Nominal
Wattage
Bulb
Nominal
Length
(in)
28
T5
48
MOL
(in)
Product
Number Ordering Abbreviation
Base
45.8
Mini Bipin 20868
20901
20902
14
T5
24
22.2
34
57.6
85
40
40
20000
20000
3500
4100
85
85
2600
2900
2418
2697
74,76
2600
2900
2418
2697
74,76
2600
2900
2418
2697
74,76
31,33,38,48,
31,33,38,48,
2545
2840
2367
2641
74,76
20990
FP28/865/ECO
40
20000
6500
85
2400
2750
2232
2558
74,76
31,33,38,48,
FP28RED 40/CS 1/SKU
40
20000
2100
15,31,33,38,48,74
20978
FP28GREEN 40/CS 1/SKU40
20000
3500
15,31,33,38,48,74
20986
FP28BLUE 40/CS 1/SKU 40
20000
700
15,31,33,38,48,74
FP14/830/ECO
20000
Mini Bipin 20919
Mini Bipin 20925
20926
20927
FP14/835/ECO
FP14/841/ECO
FP14/865/ECO
FP21/830/ECO
FP21/835/ECO
FP21/841/ECO
FP21/865/ECO
FP35/830/ECO
FP35/835/ECO
FP35/841/ECO
40
40
40
40
40
40
40
40
40
40
40
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
3000
3500
4100
6500
3000
3500
4100
6500
3000
3500
4100
85
85
85
85
85
85
85
85
85
85
85
F
L
U
O
R
E
S
C
E
N
T
31,33,38,48,
20977
Mini Bipin 20907
|
|
|
|
31,33,38,48,
85
20989
60
3000
5000
20924
T5
20000
20000
20921
35
40
40
20988
36
FP28/841/ECO
CRI
FP28/850/ECO
20914
T5
FP28/835/ECO
CCT
(K)
Approx Lumens
Initial
Mean
@25°C/77°F Symbols &
(@35°C/95°F) Footnotes
22203
20908
21
FP28/830/ECO
Pkg
Qty
Avg Rated Life
@3hrs/start
(@12hrs/start)
1200
1350
1116
1256
74,76
1200
1350
1116
1256
74,76
1200
1350
1116
1256
74,76
1100
1300
1045
1209
74,76
1900
2100
1767
1953
74,76
1900
2100
1767
1953
74,76
1900
2100
1767
1953
74,76
1750
2000
1662
1860
74,76
3300
3650
3069
3394
74,76
3300
3650
3069
3394
74,76
3300
3650
3069
3394
74,76
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,38,48,
PENTRON® PREMIER™ High Performance T5 Lamps
45
Avg
Nominal
Wattage
Bulb
Nominal
Length
(in)
28
T5
48
MOL
(in)
Product
Number Ordering Abbreviation
Base
45.8
Mini Bipin 20948
20943
20944
For more complete product information visit www.sylvania.com
FP28/830PM/ECO
FP28/835PM/ECO
FP28/841PM/ECO
Pkg
Qty
Avg Rated Life
@3hrs/start
(@12hrs/start)
CCT
(K)
CRI
40
20000
3000
85
40
40
20000
20000
3500
4100
85
85
Approx Lumens
Initial
Mean
@25°C/77°F Symbols &
(@35°C/95°F) Footnotes
2730
3050
2594
2898
74,76
2730
3050
2594
2898
74,76
2730
3050
2594
2898
74,76
|
|
|
|
31,33,38,48,
31,33,38,48,
31,33,38,48,
Symbols/Footnotes on page 160-165
143
055_FL_print.qxd
12/12/07
3:39 PM
Page 144
T5 Mini Bipin
PENTRON® T5 FLUORESCENT LAMPS
PENTRON® High Output, High Performance T5 Lamps
45
Avg
Nominal
Wattage
Bulb
Nominal
Length
(in)
54
T5
48
MOL
(in)
Product
Number Ordering Abbreviation
Base
45.8
Mini Bipin 20903
20904
21020
20906
21021
F
L
U
O
R
E
S
C
E
N
T
20949
21022
20862
24
T5
24
22.2
36
34
60
57.6
FP54/841/HO/ECO/SL
FP54/850/HO/ECO
FP54/850/HO/ECO/SL
FP54/865/HO/ECO
40
40
40
40
40
3000
85
25000
(35000)
3500
25000
(35000)
3500
25000
(35000)
4100
25000
(35000)
4100
25000
(35000)
5000
25000
(35000)
5000
25000
(35000)
6500
85
85
85
85
85
85
85
4450
5000
4138
4650
74,76
4450
5000
4138
4650
74,76
4316
4850
4014
4510
74,76,96,98
4450
5000
4138
4650
74,76
4316
4850
4014
4510
76,96,98
4375
4900
4069
4557
74,76
4243
4753
3946
4420
76,96,98
4050
4750
3766
4418
74,76
31,33,38,48,
31,33,38,48,
31,33,38,48,
31,33,48,74,
31,33,38,48,
31,33,48,74,
31,33,38,48,
3300
15,31,33,38,48,74
20998
FP54/GREEN/HO
40
20000
5550
15,31,33,38,48,74
20999
FP54/BLUE/HO
40
20000
1150
15,31,33,38,48,74
FP24/830/HO/ECO
40
20000
Mini Bipin 20928
Mini Bipin 20932
Mini Bipin 20935
20936
20937
FP24/835/HO/ECO
FP24/841/HO/ECO
FP39/830/HO/ECO
FP39/835/HO/ECO
FP39/841/HO/ECO
FP80/830/HO/ECO
FP80/835/HO/ECO
FP80/841/HO/ECO
40
40
40
40
40
40
40
40
20000
20000
20000
20000
20000
20000
20000
20000
3000
3500
4100
3000
3500
4100
3000
3500
4100
85
85
85
85
85
85
85
85
85
|
|
|
|
31,33,38,48,
20000
20934
T5
FP54/841/HO/ECO
40
25000
(35000)
40
20933
80
FP54/835/HO/ECO/SL
40
CRI
FP54/RED/HO
20931
T5
FP54/835/HO/ECO
40
CCT
(K)
Approx Lumens
Initial
Mean
@25°C/77°F Symbols &
(@35°C/95°F) Footnotes
20997
20929
39
FP54/830/HO/ECO
Pkg
Qty
Avg Rated Life
@3hrs/start
(@12hrs/start)
1750
2000
1627
1750
2000
1627
1750
2000
1627
3100
3500
2883
3101
3500
2883
3102
3500
2883
6150
7000
5719
6510
74,76
6151
7000
5720
6510
74,76
6152
7000
5721
6510
74,76
31,33,38,48,
74,76
31,33,38,48,
74,76
31,33,38,48,
74,76
31,33,38,48,
74,76
31,33,38,48,
74,76
31,33,38,48,
74,76
31,33,38,48,
31,33,38,48,
31,33,38,48,
PENTRON® High Output, Wide Temperature Range T5 Lamps
45
Avg
Nominal
Wattage
Bulb
Nominal
Length
(in)
54
T5
48
MOL
(in)
Base
Product
Number Ordering Abbreviation
45.8
Mini Bipin 21042
21043
21044
For more complete product information visit www.sylvania.com
144
FP54/835/C/HO/ECO
FP54/841/C/HO/ECO
FP54/850/C/HO/ECO
Pkg
Qty
40
40
40
Avg Rated Life
@3hrs/start
(@12hrs/start)
CCT
(K)
CRI
25000
(35000)
3500
85
25000
(35000)
4100
25000
(35000)
5000
85
85
Approx Lumens
Initial
Mean
@25°C/77°F Symbols &
(@35°C/95°F) Footnotes
4900
4900
4655
4655
74,76
4900
4900
4655
4655
74,76
4800
4800
4560
4560
74,76
|
|
|
|
31,33,38,48,
31,33,38,48,
31,33,38,48,
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
Circline 4-Pin T5
Page 145
T12 Med Bipin
PENTRON® T5 FLUORESCENT LAMPS
PENTRON® Circline T5 Lamps
46
Nominal
Wattage
22
40
55
Avg
Bulb
Outside
Diameter (in)
T5
8.66 - 9.06
T5
11.54 - 12.01
T5
11.54 - 12.01
Avg Rated Life
@3hrs/start
CCT
(@12hrs/start) (K)
CRI
Approx Lumens
Initial
Mean Symbols &
@25°C/77°F Footnotes
20702
FPC22/830
12
12000
3000
82
1800
1585
31,33,38,48,74
20712
FPC22/835
12
12000
3500
82
1800
1585
31,33,38,48,74
20715
FPC22/841
12
12000
4100
82
1800
1585
31,33,38,48,74
Base
2GX13
2GX13
2GX13
|
|
|
Ordering Abbreviation
Pkg
Qty
Product
Number
20731
FPC40/830
12
12000
3000
82
3200
2815
31,33,38,48,74
20732
FPC40/835
12
12000
3500
82
3200
2815
31,33,38,48,74
20733
FPC40/841
12
12000
4100
82
3200
2815
31,33,38,48,74
20741
FPC55/830/HO
12
12000
3000
82
4000
3520
31,33,38,48,74
20750
FPC55/835/HO
12
12000
3500
82
4000
3520
31,33,38,48,74
20751
FPC55/841/HO
12
12000
4100
82
4000
3520
31,33,38,48,74
RAPID START LAMPS
Rapid Start lamps, 3-foot and 4-foot in length, are typically designated by their wattage: e.g. F40 = Fluorescent 40W. Therefore lamps previously designated as
F30T12/RS/SS, F40/SS and FB40/SS energy saving types will now be designated as F25T12/RS/SS, F34/SS and FB34/SS, respectively to comply with standard
lamp designation nomenclature for these families of lamps.
3’ SUPERSAVER® Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
25
36
Med Bipin
23473
T12
35.78
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
F25T12/WW/RS/SS
30
formerly F30T12/WW/RS/SS
18000
3000
52
1975
1679
23485
F25T12/D35/RS/SS
30
formerly F30T12/D35/RS/SS
18000
3500
70
2050
1804
23472
F25T12/CW/RS/SS
30
formerly F30T12/CW/RS/SS
18000
4200
60
1925
1636
Pkg
Qty
|
|
|
22,31,33
22,31,33
22,31,33
3’ Standard Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
30
36
T12
35.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
23490
F30T12/SW/RP
6
18000
3000
52
2275
1934
30,31,33,48
23482
F30T12/WW/RS
30
18000
3000
52
2275
1934
30,31,33,48
23474
F30T12/D830/RS
30
18000
3000
80
2290
2061
30,31,33,48
23484
F30T12/D35/RS
30
18000
3500
70
2250
1980
30,31,33,48
23139
F30T12/D835/RS
30
18000
3500
80
2290
2061
30,31,33,48
23493
F30T12/CW/RP
6
18000
4200
60
2200
1870
30,31,33,48
23476
F30T12/CW/RS
30
18000
4200
60
2200
1870
30,31,33,48
23487
F30T12/CW/RS/UPC
30
18000
4200
60
2200
1870
30,31,33,48
23478
F30T12/D/RS
30
18000
6500
76
1900
1615
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
F34WW/SS/ECO
formerly F40WW/SS/ECO
30
20000
52
F34/D30/SS/ECO
formerly F40/D30/SS/ECO
30
|
|
|
30,31,33,48
®
4’ SUPERSAVER Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
34
48
Med Bipin
24538
T12
47.78
24535
For more complete product information visit www.sylvania.com
3000
2750
2365
|
|
|
2,24,30,31,
33,56,76
20000
3000
70
2800
2520
2,24,30,
31,33,56,76
Symbols/Footnotes on page 160-165
145
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
Page 146
T12 Med Bipin
RAPID START LAMPS
4’ SUPERSAVER® Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
34
48
T12
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
24589
30
20000
80
24544
3000
2900
2610
20000
24591
F34W/SS
formerly F40W/SS
30
20000
3450
57
2750
2365
24585
F34/D35/SS
formerly F40/D35/SS
30
20000
3500
70
2800
2520
F34/D35/SS/CVP
formerly F40/D35/SS/CVP
10
F34/D35/SS/ECO
formerly F40/D35/SS/ECO
30
24540
24547
24542
24554
2,24,30,31,
33,56
F34/D830/SS/ECO
30
formerly F40/D830/SS/ECO
24522
F
L
U
O
R
E
S
C
E
N
T
F34/D830/SS
formerly F40/D830/SS
3000
80
2900
2610
2,24,30,
31,33,56,76
2,24,30,31,33,56
2,24,30,31,
33,56
20000
3500
70
2800
2520
2,24,30,31,
33,56
20000
3500
70
2800
2520
2,24,30,
31,33,56,76
F34/D835/SS/ECO
30
formerly F40/D835/SS/ECO
20000
F34/D41/SS/ECO
formerly F40/D41/SS/ECO
20000
30
3500
80
2900
2610
2,24,30,
31,33,56,76
4100
70
2800
2520
2,24,30,
31,33,56,76
F34/D841/SS/ECO
30
formerly F40/D841/SS/ECO
20000
24588
F34CWX/SS
formerly F40CWX/SS
30
20000
4100
87
1925
1656
24566
F34LW/SS/ECO
formerly F40LW/SS/ECO
30
20000
4150
48
2825
2430
24590
F34LW/SS
formerly F40LW/SS
30
20000
4150
48
2825
2430
2,24,30,31,33,56
24516
F34CW/SS/10
formerly F40CW/SS/10
10
20000
4200
60
2650
2279
2,24,30,31,33,56
24524
F34CW/SS/CVP
formerly F40/CW/SS/CVP
10
20000
4200
60
2650
2279
2,24,30,31,33,56
24396
F34CW/SS/SL
formerly F40CW/SS/SL
30
20000
4200
60
2570
2313
F34CW/SS/ECO
formerly F40CW/SS/ECO
30
24596
24632
4100
80
2900
2610
2,24,30,31,33,56
2,24,30,31,
33,56,76
2,24,30,31,33,96,
98
20000
4200
60
2650
2279
2,24,30,31,
33,56,76
20000
F34CW/SS/ECO/CVP30
30
formerly F40CW/SS/ECO/CVP30
20000
F34CW/SS/ECO/RP
30
formerly F40/CW/SS/ECO/RP
20000
24599
F34/DX/SS
formerly F40/DX/SS
30
20000
6500
88
1930
1565
24706
F34/D865/SS
formerly F40/D865/SS
30
20000
6500
80
2650
2385
24633
2,24,30,
31,33,56,76
F34CW/SS/ECO/CVP
10
formerly F40/CW/SS/ECO/CVP
24642
|
|
|
4200
60
2650
2279
2,24,30,31,
33,56,76
4200
60
2650
2279
2,24,30,31,
33,56,76
4200
60
2650
2279
2,24,30,31,
33,48,56,76
2,24,30,31,33,56
2,24,30,31,
33,56
4’ Standard Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
40
48
T12
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
24521
30
20000
70
F40/D30/ECO
3000
3200
2880
|
|
|
2,30,31,
33,48,56,64,76
For more complete product information visit www.sylvania.com
146
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
T12 Med Bipin
Page 147
T12 U-Shaped 6"
RAPID START LAMPS
4’ Standard Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
40
48
T12
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
24543
30
20000
80
F40/D830/ECO
3000
3300
2970
|
|
|
2,30,31,
33,48,56,64,76
24537
F40/D35/ECO
30
20000
3500
70
3200
2880
2,30,31,
33,48,56,64,76
24546
F40/D835/ECO
30
20000
3500
80
3300
2970
2,30,31,
33,48,56,64,76
24438
F40N
30
20000
3600
86
2100
1806
2,30,31,33,48,56,
64
24442
F40CWX 10/CS
10
20000
4100
87
2150
1849
2,30,31,33,48,56,
F
L
U
O
R
E
S
C
E
N
T
64
24441
F40CWX
30
20000
4100
87
2150
1849
2,30,31,33,48,56,
64
24541
F40/D41/ECO
30
20000
4100
70
3200
2880
2,30,31,
33,48,56,64,76
24553
F40/D841/ECO
30
20000
4100
80
3300
2970
2,30,31,
33,48,56,64,76
24584
F40/D41
30
20000
4100
70
3200
2880
2,30,31,33,
48,56,64
24683
F40DSGN50
30
20000
5000
90
2200
1892
2,30,31,33,48,56,
64
24477
F40/DX
30
20000
6500
88
2180
1770
2,30,31,33,48,56,
64
24570
F40/D865
30
20000
6500
80
3000
2700
2,30,31,33,
48,56,64
24673
®
F40/GO
10
20000
1980
2,30,31,33,48,56,64
®
CURVALUME SUPERSAVER Rapid Start Lamps – U-Shaped, 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
34
22.5
T12
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
24062
FB34/WW/6/SS/UPC
formerly FB40/WW/6/SS
12
18000
3000
52
2650
2279
24052
FB34/WW/6/SS/ECO
12
formerly FB40/WW/6/SS/ECO
18000
3000
52
2650
2279
24065
FB34/D35/6/SS
formerly FB40/D35/SS
12
18000
3500
70
2730
2457
24059
FB34/CW/6/SS/UPC
formerly FB40/CW/SS/6
12
18000
4200
60
2600
2236
24054
FB34/CW/6/SS/ECO
12
formerly FB40/CW/6/SS/ECO
18000
4200
60
2600
2236
|
|
|
24,30,31,33
24,30,31,33,
76
24,30,31,33
24,30,31,33
24,30,31,33,
76
CURVALUME® Standard Rapid Start Lamps – U-Shaped, 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
40
22.5
Med Bipin
T12
22.6
For more complete product information visit www.sylvania.com
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
|
|
|
24080
FB40/D30/6
12
18000
3000
70
3050
2745
30,31,33,48
24017
FB40/D830/6
12
18000
3000
80
3200
2880
30,31,33,48
24081
FB40/D35/6
12
18000
3500
70
3050
2745
24004
FB40/CWX/6
12
18000
4100
87
2100
1806
30,31,33,48
30,31,33,48
Symbols/Footnotes on page 160-165
147
055_FL_print.qxd
12/12/07
3:39 PM
T12 U-Shaped 6"
Page 148
Circline 4-Pin T9
T12 RDC
RAPID START LAMPS
CURVALUME® Standard Rapid Start Lamps – U-Shaped, 6” Leg Spacing
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
40
22.5
T12
22.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
24082
12
18000
70
FB40/D41/6
4100
3050
2745
|
|
|
30,31,33,48
Circline T9 Rapid Start Lamps
46
Nominal
Wattage
20
22
F
L
U
O
R
E
S
C
E
N
T
Avg
Bulb
Outside
Diameter (in)
Base
T9
6.25 - 6.75
4 PIN
T9
8.00 - 8.50
4 PIN
30
T9
8.00 - 8.50
4 PIN
32
T9
11.5 - 12.0
4 PIN
40
T9
15.6 - 16.0
4 PIN
Product
Number
Ordering Abbreviation
Pkg
Qty
Avg Rated Life
@3hrs/start
CCT
(@12hrs/start) (K)
CRI
Approx Lumens
Initial
Mean Symbols &
@25°C/77°F Footnotes
20155
FC6T9/WW/RS
12
8000
3000
52
800
696
31,33,42,48
20156
FC6T9/CW/RS
12
8000
4200
60
750
653
31,33,42,48
31,33,42,48
20088
FC8T9/WW/RS
12
12000
3000
52
1050
914
20209
FC8T9/DSW/RP
6
12000
3000
70
1100
990
20151
FC8T9/CW/RS/6 PACK
6
12000
4200
60
1050
914
31,33,42,48
20148
FC8T9/CW/RS
12
12000
4200
60
1050
914
31,33,42,48
20080
FC8T9/D/RS
12
12000
6500
76
900
783
31,33,42,48
20210
FC8T9/830/EL
6
10000
3000
80
1850
1591
31,33,40,49,79,81
|
|
|
31,33,42,48
20233
FC12T9/DSW/RP
6
15000
3000
70
2100
1806
20037
FC12T9/WW/RS
12
15000
3000
52
1950
1697
31,33,42,48
20143
FC12T9/CW/RS/6 PACK
6
15000
4200
60
1925
1675
31,33,42,48
20142
FC12T9/CW/RS
12
15000
4200
60
1925
1675
31,33,42,48
20030
FC12T9/D/RS
12
15000
6500
76
1650
1436
20057
FC16T9/WW/RS
12
18000
3000
52
2800
2436
31,33,42,48
20132
FC16T9/CW/RS
12
18000
4200
60
2750
2393
31,33,42,48
20072
FC16T9/D/RS
12
18000
6500
76
2350
2045
31,33,42,48
31,33,42,48
31,33,42,48
®
High Output (800mA) SUPERSAVER Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
55
T12
48
46
Recessed DC
25137
F48T12D35/HO/SS
30
12000
3500
70
3750
3375
27,31,33,97
95
T12
96
93.91
Recessed DC
27,31,33,97
25011
F96T12/WW/HO/SS
15
12000
3000
52
7700
6237
25024
F96T12/D35/HO/SS
15
12000
3500
48
8350
7515
25023
F96T12/D41/HO/SS
15
12000
4100
70
8350
7515
25025
F96T12/LW/HO/SS
15
12000
4150
48
8000
6480
27,31,33,97
25010
F96T12/CW/HO/SS
15
12000
4200
60
8000
6480
27,31,33,97
25001
F96T12/CW/HO/SS/ECO
15
12000
4200
60
8000
6480
|
|
|
27,31,33,97
27,31,33,97
27,31,33,76,
97
High Output (800mA) Standard Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
25
T12
18
15.91
Recessed DC
25303
F18T12/DSGN50/HO
30
9000
5000
90
850
740
35
T12
24
21.91
Recessed DC
For more complete product information visit www.sylvania.com
148
|
|
|
31,33,48
25313
F24T12/CW/HO
30
9000
4200
60
1650
1337
25312
F24T12/DSGN50/HO
30
9000
5000
90
1200
1044
31,33,48
25314
F24T12/D/HO
30
9000
6500
76
1400
1134
31,33,48
31,33,48
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
Page 149
T12 RDC
RAPID START LAMPS
High Output (800mA) Standard Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
42
T12
30
45
T12
36
55
60
75
80
85
100
110
T12
T12
T12
T12
T12
T12
T12
42
48
60
64
72
84
96
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
27.91
Recessed DC
25322
F30T12/CW/HO
30
9000
4200
60
2250
1825
31,33,48
33.91
Recessed DC
31,33,48
39.91
46
57.91
61.91
69.91
81.91
93.91
Recessed DC
Recessed DC
Recessed DC
Recessed DC
Recessed DC
Recessed DC
Recessed DC
For more complete product information visit www.sylvania.com
25333
F36T12/CW/HO
30
9000
4200
60
2850
2309
25334
F36T12/DSGN50/HO
30
9000
5000
90
2100
1701
25332
F36T12/D/HO
30
9000
6500
76
2500
2025
25342
F42T12/CW/HO
30
9000
4200
60
3400
2754
25344
F42T12/DSGN50/HO
30
9000
5000
90
2550
2066
31,33,48
25343
F42T12/D/HO
30
9000
6500
76
3050
2471
31,33,48
|
|
|
31,33,48
31,33,48
31,33,48
25147
F48T12/WW/HO
30
12000
3000
52
4130
3345
25148
F48T12/D830/HO
30
12000
3000
80
4400
4048
31,33,48,97
25154
F48T12/D35/HO
30
12000
3500
70
4250
3825
31,33,48,97
25136
F48T12/D41/HO
30
12000
4100
70
4250
3443
31,33,48,97
25146
F48T12/CW/HO
30
12000
4200
60
4050
3281
25122
F48T12/CW/HO/ECO
30
12000
4200
60
4050
3281
31,33,48,76,97
25153
F48T12/DSGN50/HO
30
12000
5000
90
3050
2471
31,33,48,97
25150
F48T12/D/HO
30
12000
6500
76
3600
2916
31,33,48,97
25128
F60T12/D35/HO
30
12000
3500
70
5600
5040
25126
F60T12/CW/HO
30
12000
4200
60
5200
4212
25119
F60T12/DSGN50/HO
30
12000
5000
90
3850
3119
31,33,48,97
25120
F60T12/D/HO
30
12000
6500
76
4600
3826
31,33,48,97
31,33,48,97
F
L
U
O
R
E
S
C
E
N
T
31,33,48,97
31,33,48,97
31,33,48,97
25352
F64T12/CW/HO
30
12000
4200
60
5750
4658
25355
F64T12/DSGN50/HO
30
12000
5000
90
4200
3402
31,33,48,97
25353
F64T12/D/HO
30
12000
6500
76
4900
3969
31,33,48,97
25098
F72T12/D830/HO
15
12000
3000
80
6750
6210
1,31,33,48,97
25177
F72T12/WW/HO
15
12000
3000
52
6400
5184
27249
F72T12/D35/HO
15
12000
3500
70
6650
5985
1,31,33,48,97
25281
F72T12/D835/HO
15
12000
3500
80
6750
6210
1,31,33,48,97
25182
F72T12/N/HO
15
12000
3600
86
4400
3564
1,31,33,48,97
27245
F72T12/D41/HO
15
12000
4100
70
6650
5985
25176
F72T12/CW/HO
15
12000
4200
60
6250
5063
25171
F72T12/CW/HO/ECO
15
12000
4200
60
6250
5063
1,31,33,48,76
25190
F72T12/DSGN50/HO
15
12000
5000
90
4600
3726
1,31,33,48,97
25189
F72T12/D/HO
15
12000
6500
76
5550
4496
25384
F84T12/CW/HO
15
12000
4200
60
7550
6115
25386
F84T12/DSGN50/HO
15
12000
5000
90
5600
4536
31,33,48,97
25385
F84T12/D/HO
15
12000
6500
76
6700
5427
31,33,48,97
31,33,48,97
1,31,33,48,97
1,31,33,48,97
1,31,33,48,97
1,31,33,48,97
31,33,48,97
25149
F96T12/D30/HO
15
12000
3000
70
9050
8145
31,33,48,97
25152
F96T12/D830/HO
15
12000
3000
80
9400
8648
31,33,48,97
25165
F96T12/D35/HO
15
12000
3500
70
9050
8145
31,33,48,97
25166
F96T12/D835/HO
15
12000
3500
80
9400
8648
31,33,48,97
25162
F96T12/N/HO
15
12000
3600
86
6050
4900
25184
F96T12/D41/HO
15
12000
4100
70
9050
8145
31,33,48,97
31,33,48,97
Symbols/Footnotes on page 160-165
149
055_FL_print.qxd
12/12/07
3:39 PM
T12 RDC
Page 150
T12 Single Pin
RAPID START LAMPS
High Output (800mA) Standard Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
110
96
T12
93.91
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Recessed DC
25164
F96T12/DSGN50/HO
15
12000
5000
90
6450
5225
25185
F96T12/D865/HO
15
12000
6500
80
8800
7920
|
|
|
31,33,48,97
31,33,48,97
High Output (800mA) Rapid Start Lamps for Cold Temperature Operation
F
L
U
O
R
E
S
C
E
N
T
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
110
96
93.91
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Recessed DC
25118
F96T12/CW/HO/COLD/10/CVP
10
12000
4200
60
8600
6966
25129
F96T12/CW/HO/CT/ECO
15
12000
4200
60
8600
6966
25134
F96T12/CW/HO/COLD TEMP
15
12000
4200
60
8600
6966
F96T12/D/HO/COLD TEMP
15
12000
6500
76
7600
6156
25135
|
|
|
31,33,48,91,97
31,33,48,76,91,97
31,33,48,91,97
31,33,48,91,97
®
Very High Output (1500mA) SUPERSAVER Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
195
96
T12
93.91
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Recessed DC
25296
15
10000
60
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
F96T12/CW/VHO/SS
4200
13000 9100
|
|
|
28,31,33,48,108
Very High Output (1500mA) Standard Rapid Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
115
48
Recessed DC
25248
F48T12/CW/VHO
30
10000
4200
60
6600
4620
31,33,48,108
25249
F48T12/CW/VHO/LT
30
10000
4200
60
6750
5250
31,33,48,58,88,108
25244
F48T12/D/VHO
30
10000
6500
76
5600
3920
31,33,48,108
T12
46
135
T12
60
57.91
Recessed DC
25262
F60T12/CW/VHO
30
10000
4200
60
8700
6090
31,33,48,108
141
T12
60
57.91
Recessed DC
25263
F60T12/CW/VHO/LT
30
10000
4200
60
8700
6090
31,33,48,58,88,108
160
T12
72
69.91
Recessed DC
215
T12
96
93.91
Recessed DC
25272
F72T12/CW/VHO
15
10000
4200
60
10600 7420
31,33,48,108
25274
F72T12/CW/VHO/LT
15
10000
4200
60
11000 7700
31,33,48,58,88,108
25270
F72T12/D/VHO
15
10000
6500
76
9400
25209
F96T12/CW/VHO
15
10000
4200
60
14000 9800
31,33,48,108
25292
F96T12/CW/VHO/LT
15
10000
4200
60
15000 10500
31,33,48,58,88,108
25210
F96T12/D/VHO
15
10000
6500
76
11600 8120
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
6580
|
|
|
31,33,48,108
31,33,48,108
INSTANT START LAMPS
Slimline SUPERSAVER® Instant Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
32
48
Single Pin
24829
F48T12/D35/SS
30
9000
3500
70
2575
2369
24825
F48T12/D41/SS
30
9000
4100
70
2575
2369
24823
F48T12/CW/SS
30
9000
4200
60
2450
2200
29900
F96T12/D41/SSP/ECO
15
12000
4100
82
5600
5152
57
T12
T12
96
46.00
94
Single Pin
|
|
|
26,31,33
26,31,33
26,31,33
26,31,33,
76,97
For more complete product information visit www.sylvania.com
150
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
T12 Single Pin
Page 151
T6 Single Pin
T8 Single Pin
INSTANT START LAMPS
Slimline SUPERSAVER® Instant Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
60
96
T12
94
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Single Pin
29795
15
12000
52
F96T12/WW/SS/ECO
3000
5500
4840
|
|
|
26,31,33,76,
97
29809
F96T12/D30/SS/ECO
15
12000
3000
70
5600
5152
26,31,33,
76,97
29854
F96T12/D830/SS/ECO
15
12000
3000
80
5800
5452
26,31,33,
76,97
29819
F96T12/D35/SS
15
12000
3500
70
5600
5152
29808
F96T12/D35/SS/ECO
15
12000
3500
70
5600
5152
26,31,33,97
26,31,33,
76,97
29811
F96T12/D835/SS
15
12000
3500
80
5800
5452
29859
F96T12/D835/SS/ECO
15
12000
3500
80
5800
5452
F
L
U
O
R
E
S
C
E
N
T
26,31,33,97
26,31,33,
76,97
29853
F96T12/D41/SS/ECO
15
12000
4100
70
5600
5152
26,31,33,
76,97
29860
F96T12/D841/SS/ECO
15
12000
4100
80
5800
5452
26,31,33,
76,97
29820
F96T12/LW/SS
15
12000
4150
48
5600
4928
26,31,33,97
29815
F96T12/CW/SS
15
12000
4200
60
5300
4664
26,31,33,97
29805
F96T12/CW/SS/CVP
10
12000
4200
60
5300
4664
26,31,33,97
29816
F96T12/CW/SS/UPC
15
12000
4200
60
5300
4664
26,31,33,97
29555
F96T12/CW/SS/SL
15
12000
4200
60
5140
4420
26,31,33,96,97,98
29505
F96T12/CW/SS/ECO
15
12000
4200
60
5300
4664
26,31,33,76,
97
29851
F96T12/D865/SS
15
12000
6500
80
5300
4770
29828
F96T12/DX/SS
15
12000
6500
88
3860
3397
29868
F96T12/DX/SS/ECO
15
12000
6500
88
3860
3397
26,31,33,97
26,31,33,97
26,31,33,76,
97
Slimline Standard Instant Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
21
T12
24
25
T6
42
22
Single Pin
22403
F24T12/CW
30
7500
4200
60
1150
1000
31,33,48
40
Single Pin
24270
F42T6/WW
24
7500
3032
52
1825
1606
31,33,48
24269
F42T6/D35
24
7500
3500
70
1830
1684
24266
F42T6/CW
24
7500
4200
60
1750
1540
31,33,48
31,33,48
30
T12
36
34
Single Pin
23618
F36T12/CW
30
7500
4200
60
1970
1734
38
T6
64
62
Single Pin
26470
F64T6/WW
24
7500
3000
52
2900
2552
31,33,48
26466
F64T6/CW
24
7500
4200
60
2800
2464
31,33,48
T8
72
70
Single Pin
27270
F72T8/WW
24
7500
3000
52
3100
2728
31,33,48
27266
F72T8/CW
24
7500
4200
60
3050
2684
31,33,48
27200
F72T8/D
24
7500
6500
76
2600
2288
39
T12
48
46
Single Pin
For more complete product information visit www.sylvania.com
|
|
|
31,33,48
31,33,48
24832
F48T12/D35
30
9000
3500
70
3000
2760
31,33,48
24827
F48T12/CW/ECO
30
9000
4200
60
2820
2482
31,33,48,76
24830
F48T12/CW
30
9000
4200
60
2820
2482
31,33,48
Symbols/Footnotes on page 160-165
151
055_FL_print.qxd
12/12/07
3:39 PM
T8 Single Pin
Page 152
T12 Single Pin
INSTANT START LAMPS
Slimline Standard Instant Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
39
T12
48
50
T12
60
51
F
L
U
O
R
E
S
C
E
N
T
52
55
T8
T12
T12
96
64
72
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
46
Single Pin
24834
F48T12/D
30
9000
6500
76
2450
2156
24836
F48T12D/ECO
30
9000
6500
76
2450
2156
58
Single Pin
26018
F60T12/D35
30
12000
3500
70
3850
3542
26001
F60T12/CW
30
12000
4200
60
3700
3256
26002
F60T12/D
30
12000
6500
76
3000
2640
31,33,48,97
31,33,48
94
62
70
Single Pin
Single Pin
Single Pin
29666
F96T8/CW
24
7500
4200
60
4000
3520
29650
F96T8/D
24
7500
6500
76
3550
3124
31,33,48
31,33,48,76
31,33,48,97
31,33,48,97
31,33,48
26403
F64T12/CW
30
12000
4200
60
3900
3432
26404
F64T12/D
30
12000
6500
76
3300
2904
31,33,48,97
31,33,48,97
27255
F72T12/D830
15
12000
3000
80
4800
4512
31,33,48,97
27250
F72T12/D35
15
12000
3500
70
4700
4324
31,33,48,97
27243
F72T12/D41
15
12000
4100
70
4700
4324
27256
F72T12/CW
15
12000
4200
60
4500
3960
27259
F72T12/D
15
12000
6500
76
3800
3432
70
T12
84
82
Single Pin
28417
F84T12/CW
15
12000
4200
60
5300
4664
75
T12
96
94
Single Pin
29796
F96T12/D30/ECO
15
12000
3000
70
6420
5906
|
|
|
31,33,48,97
31,33,48,97
31,33,48,97
31,33,48,97
31,33,48,
76,97
29827
F96T12/D830
15
12000
3000
80
6550
6157
29856
F96T12/D830/ECO
15
12000
3000
80
6550
6157
31,33,48,97
31,33,48,
76,97
29685
F96T12/D35
15
12000
3500
70
6420
5906
29686
F96T12/D35/ECO
15
12000
3500
70
6420
5906
31,33,48,97
31,33,48,
76,97
29843
F96T12/D835
15
12000
3500
80
6550
6157
29838
F96T12/D835/ECO
15
12000
3500
80
6550
6157
31,33,48,97
31,33,48,
76,97
29797
F96T12/D41/CVP
10
12000
4100
70
6420
5906
29478
F96T12/CWX
15
12000
4100
87
4400
3872
31,33,48,97
29858
F96T12/CWX/CVP
10
12000
4100
87
4400
3872
31,33,48,97
29489
F96T12/CWX/UPC
15
12000
4100
87
4400
3872
31,33,48,97
29852
F96T12/D41/UPC
15
12000
4100
70
6420
5906
29798
F96T12/D41/ECO
15
12000
4100
70
6420
5906
31,33,48,97
31,33,48,97
31,33,48,
76,97
29857
F96T12/D841
15
12000
4100
80
6550
6157
29850
F96T12/D841/ECO
15
12000
4100
80
6550
6157
31,33,48,97
31,33,48,
76,97
For more complete product information visit www.sylvania.com
152
29833
F96T12/DSGN50
15
12000
5000
90
4400
3872
29849
F96T12/D865
15
12000
6500
80
6000
5520
29500
F96T12/DX
15
12000
6500
88
4360
3837
31,33,48,97
31,33,48,97
31,33,48,97
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
T5 Mini Bipin
Page 153
T8 Med Bipin
T12 Med Bipin
PREHEAT LAMPS
Miniature T5 Preheat Lamps (Starter Required)
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
4
T5
6
6
T5
9
8
13
T5
T5
12
21
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
5.91
Mini Bipin
20416
F4T5/CW
24
6000
4200
60
135
117
31,33
20415
F4T5CW/BL/1/6
6
6000
4200
60
135
117
31,33
8.91
Mini Bipin
20617
F6T5/WW
24
7500
3000
52
275
239
31,33
20619
F6T5CW/BL/1/6
6
7500
4200
60
270
235
31,33
20616
F6T5/CW
24
7500
4200
60
270
235
31,33
11.91
20.91
Mini Bipin
Mini Bipin
20817
F8T5/WW
24
7500
3000
52
400
348
31,33
20819
F8T5/SW/BL/1/6
6
7500
3000
52
400
348
31,33
20837
F8T5/CWX
24
7500
4100
87
270
235
20816
F8T5/CW
24
7500
4200
60
390
339
31,33
20834
F8T5CW/BL/1/6
6
7500
4200
60
390
339
31,33
20820
F8T5/D
24
7500
6500
76
350
305
|
|
|
31,33
F
L
U
O
R
E
S
C
E
N
T
31,33
21317
F13T5/WW
24
7500
3000
52
880
766
31,33
21316
F13T5/CW
24
7500
4200
60
860
748
31,33
21315
F13T5CW/BL/1/6
6
7500
4200
60
860
748
31,33
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Standard T8 and T12 Preheat Lamps (Starter Required)
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
13
T8
12
11.71
Med Bipin
21766
F13T8/CW
24
7500
4200
60
530
461
31,33
14
T8
15
14.78
Med Bipin
31,33
T12
15
T8
T12
15
18
18
14.78
17.78
17.78
Med Bipin
Med Bipin
Med Bipin
For more complete product information visit www.sylvania.com
21486
F14T8/CW
24
7500
4200
60
685
644
21488
F14T8/D
24
7500
6500
76
575
561
21435
F14T12/WW
30
9000
3000
52
660
574
21451
F14T12/DSW/RP
6
9000
3000
70
720
648
21536
F14T12/DCW/1/6/RP
6
9000
4100
70
720
648
31,33
21409
F14T12/CW
30
9000
4200
60
650
566
31,33
21410
F14T12/CW/6/RP
6
9000
4200
60
650
566
31,33
21411
F14T12/D
30
9000
6500
76
590
513
31,33
|
|
|
31,33
31,33
31,33
21656
F15T8/DSW/RP
6
7500
3000
70
900
810
31,33
21610
F15T8/D830
24
7500
3000
82
920
846
31,33
21701
F15T8/WW
24
7500
3000
52
845
735
31,33
21765
F15T8/SW/RP
6
7500
3000
52
845
735
31,33
21609
F15T8/D35
24
7500
3500
70
940
846
31,33
21682
F15T8/N
24
7500
3600
86
560
487
31,33
21603
F15T8/DCW/RP
6
7500
4100
70
900
810
21616
F15T8/CW
24
7500
4200
60
825
718
31,33
21619
F15T8/CW/6PK
6
7500
4200
60
825
718
31,33
21642
F15T8/DSGN50
24
7500
5000
90
600
539
21600
F15T8/D
24
7500
6500
76
700
653
21542
F15T12/WW
30
9000
3000
52
770
670
21551
F15T12/DSW/RP
6
9000
3000
70
770
693
21532
F15T12/CW
30
9000
4200
60
750
653
31,33
31,33
31,33
31,33
31,33
31,33
Symbols/Footnotes on page 160-165
153
055_FL_print.qxd
12/12/07
3:39 PM
T12 Med Bipin
Page 154
T8 Med Bipin
PREHEAT LAMPS
Standard T8 and T12 Preheat Lamps (Starter Required)
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
15
18
18
T12
T8
24
26
F
L
U
O
R
E
S
C
E
N
T
28
20
25
30
T12
T12
T8
17.78
23.78
25.78
27.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21513
F15T12/CW/6PK
6
9000
4200
60
750
653
21535
F15T12/DCW/RP
6
9000
4100
76
770
693
31,33
21534
F15T12/D
30
9000
6500
76
660
574
31,33
Med Bipin
Med Bipin
Med Bipin
|
|
|
31,33
23014
F18T8CW/K24
24
7500
4200
60
1190
1035
31,33
23012
F18T8CW/K24/1/12/UPC
12
7500
4200
60
1190
1035
31,33
23027
F18T8CW/K26
24
7500
4200
60
1280
1079
31,33
23025
F18T8/CW/K26PLT
3168
7500
4200
60
1280
1079
31,33
21728
F18T8/D/K26
24
7500
6500
76
1100
957
23028
F18T8CW/K28
24
7500
4200
60
1360
1131
31,33
31,33
30
29.78
Med Bipin
23030
F18T8CW/K30
24
7500
4200
60
1400
1200
31,33
24
23.78
Med Bipin
22131
F20T12/WW
30
9000
3000
52
1250
1088
31,33
22134
F20T12/WW/RP
6
9000
3000
52
1250
1088
31,33
22252
F20T12/DSW/RP
6
9000
3000
70
1300
1170
31,33
22251
F20T12/D35
30
9000
3500
70
1300
1170
31,33
22256
F20T12/DCW/RP
6
9000
4100
70
1300
1170
31,33
22078
F20T12/CW
30
9000
4200
60
1200
1044
31,33
22074
F20T12/CW/CVP/10
10
9000
4200
60
1200
1044
31,33
22015
F20T12/CW/RP
6
9000
4200
60
1200
1044
31,33
22073
F20T12/CW/UPC
30
9000
4200
60
1200
1044
31,33
22119
F20T12/DSGN50
30
9000
5000
90
880
766
31,33
22083
F20T12/D
30
9000
6500
76
1075
935
31,33
28
27.78
Med Bipin
22527
F25T12/CW/28
30
7500
4200
60
1670
1453
31,33
30
29.78
Med Bipin
22333
F25T12/WW/30
30
7500
3000
52
1750
1523
31,33
22528
F25T12/CW/30
30
7500
4200
60
1730
1505
31,33
33
32.78
Med Bipin
22529
F25T12/CW/33
30
7500
4200
60
1850
1610
31,33
36
35.78
Med Bipin
31,33
23701
F30T8/WW
24
7500
3000
52
2150
1871
23140
F30T8/DWW/RP
6
7500
3000
70
2360
2124
31,33
23182
F30T8/N
24
7500
3600
86
1500
1305
31,33
23127
F30T8/CWX
24
7500
4100
87
1550
1349
31,33
23116
F30T8/CW
24
7500
4200
60
2180
1897
31,33
23121
F30T8CW 6/CS
6
7500
4200
60
2180
1897
31,33
7500
1850
1653
23100
F30T8/D
24
40
T12
48
47.2
Med Bipin
24409
L40W/30-1
25
6500
76
3000
50
58
T8
60
59.6
Med Bipin
24729
L58W/840
25
70
T8
70
70
Med Bipin
20804
L70W / 21 - 840
25
20000
4000
80
5200
4785
31,33,48
15000
4000
80
6550
6026
31,33,48
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
30
25000
78
31,33
31
SPECIALTY FLUORESCENT LAMPS
SAFELINE® Shatter Resistant Coated Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
32
48
Med Bipin
21678
T8
47.78
FO32/735/SL
3500
2716
2444
|
|
|
31,33,52,96,
98, 119
For more complete product information visit www.sylvania.com
154
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
T8 Med Bipin
Page 155
T12 Med Bipin
T5 Mini Bipin
T12 Single Pin
T14 1/2 RDC
T2 Axial Base
SPECIALTY FLUORESCENT LAMPS
SAFELINE® Shatter Resistant Coated Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
32
48
T8
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Med Bipin
21547
30
25000
78
FO32/741ECO/SL
4100
2716
2444
|
|
|
31,33,52,
76,96,98, 119
34
54
T12
T5
48
48
47.78
45.8
Med Bipin
Mini Bipin
24396
21020
F34CW/SS/SL
formerly F40CW/SS/SL
30
FP54/835/HO/ECO/SL
40
20000
4200
60
2570
2313
2,24,30,31,33,96,
98
25000
3500
85
4316
4014
31,33,38,48,
74,76,96,98
21021
FP54/841/HO/ECO/SL
40
25000
4100
85
4316
4014
31,33,48,74,
76,96,98
21022
FP54/850/HO/ECO/SL
40
25000
5000
85
4243
3946
31,33,48,74,
76,96,98
60
T12
96
94
Single Pin
29555
F96T12/CW/SS/SL
15
12000
4200
60
5140
4420
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
26,31,33,96,97,98
Weather-Shielded Jacketed Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
70
T14.5
60
57.91
Recessed DC
21124
FJ60T12/CW/HO
8
12000
4200
60
5300
4293
31,33,48,97,116
110
T12
96
93.1
Recessed DC
21356
FJ96T12/CW/HO
8
12000
4200
60
8500
6885
31,33,48,97,116
115
T12
48
45.91
Recessed DC
21330
FJ48T12/CW/VHO/LT
12
10000
4200
60
6750
4725
31,33,48,88,108,116
165
T12
72
69.91
Recessed DC
21335
FJ72T12/CW/VHO/LT
8
10000
4200
60
10700 7490
31,33,48,88,108,116
215
T12
96
93.1
Recessed DC
21340
FJ96T12/CW/VHO/LT
8
10000
4200
60
15300 10710
31,33,48,88,108,116
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
66
|
|
|
GRO-LUX® Lamps for Plant Growth & Aquariums
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
15
T8
18
17.78
Med Bipin
21657
F15T8/GRO/AQ/RP
6
7500
20
T12
24
23.78
Med Bipin
40
T12
48
47.78
Med Bipin
22013
F20T12/GRO/AQ/WS/RP
6
9000
22029
F20T12/GRO/AQ/RP
6
9000
24671
F40/GRO/AQ/WS/RP
6
20000
3400
3400
89
89
325
31,33,48,57
750
31,33,48,57
480
31,33,48,57
1700
|
|
|
2,30,31,33,48,56,
64
24660
F40/GRO/AQ/RP
6
20000
1200
2,30,31,33,48,56,
64
Miniature T2 Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
6
8.6
T2
8.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Axial
26204
20
10000
80
FM6/830
3000
330
297
|
|
|
3,31,33,38,48,74,
118
26213
FM6/841
20
10000
4100
80
330
297
3,31,33,38,48,74,
118
8
T2
12.6
12.6
Axial
26237
FM8/830
20
10000
3000
80
540
486
3,31,33,38,48,74,
118
26232
FM8/841
20
10000
4100
80
540
486
3,31,33,38,48,74,
118
11
T2
16.6
16.6
Axial
26239
FM11/830
20
10000
3000
80
750
675
3,31,33,38,48,74,
118
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 160-165
155
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
T2 Axial Base
Page 156
Icetron
SPECIALTY FLUORESCENT LAMPS
Miniature T2 Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
11
16.6
T2
16.6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Axial
26235
20
10000
80
FM11/835
3000
750
675
|
|
|
3,31,33,38,48,74,
118
26231
FM11/841
20
10000
4100
80
750
675
3,31,33,38,48,74,
118
13
T2
20.6
20.6
Axial
26253
FM13/830
20
10000
3000
80
930
837
3,31,33,38,48,74,
118
26291
FM13/835
20
10000
3500
80
930
837
3,31,33,38,48,74,
118
26230
F
L
U
O
R
E
S
C
E
N
T
FM13/841
20
10000
4100
80
930
837
3,31,33,38,48,74,
118
ICETRON® Inductively Coupled, Electrodeless Lamps
The ICETRON® System is a unique adaptation of the inductively coupled electrodeless technology delivering high luminous efficacy and extremely long system
life of 100,000 hours in a shape uniquely suited for a variety of lighting applications. The ICETRON lamps and ballasts are designed as dedicated systems and
are not interchangeable with other lamps and ballasts. Please consult OSRAM SYLVANIA for fixture design and application assistance. An ICETRON Design
Guide is available on request.
41
Nominal
Wattage Bulb
70
Nominal
Length MOL
(in)
(in)
T17
12.32
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Mount Brkts
26087
1
100000
80
ICE70/835/2P/ECO
3500
6200
4605
|
|
|
6,31,33,38,
51,76,78,100,101
26081
ICE70/835
1
100000
3500
80
6200
4605
8,31,33,38,51,78,
100,101
26088
ICE70/841/2P/ECO
1
100000
4100
80
6200
4605
6,31,33,38,
51,76,78,100,101
26082
ICE70/841
1
100000
4100
80
6200
4605
8,31,33,38,51,78,
100,101
26089
ICE70/850/2P/ECO
1
100000
5000
80
5950
4420
6,31,33,38,
51,76,78,100,101
100
T17
12.32
Mount Brkts
26102
ICE100/835/2P/ECO
1
100000
3500
80
8000
5945
6,31,33,38,
51,76,78,100,101
26103
ICE100/841/2P/ECO
1
100000
4100
80
8000
5945
6,31,33,38,
51,76,78,100,101
26105
ICE100/850/2P/ECO
1
100000
5000
80
7600
5645
6,31,33,38,
51,76,78,100,101
26106
ICE100/BL/2P
1
6,31,33,38,51,78,100,101,
109
150
T17
16.28
Mount Brkts
26152
ICE150/835/2P/ECO
1
100000
3500
80
12000 8915
6,31,33,38,
51,76,78,100,101
26153
ICE150/841/2P/ECO
1
100000
4100
80
12000 8915
6,31,33,38,
51,76,78,100,101
26155
ICE150/850/2P/ECO
1
100000
5000
80
11650 8655
6,31,33,38,
51,76,78,100,101
26154
ICE150/BL/2P
1
31,33,38,51,78,100,
101,109
®
ICETRON Inductively Coupled Electrodeless Reflector Lamp
41
Nominal
Wattage Bulb
100
T17
Nominal
Length MOL
(in)
(in)
12.32
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Mount Brkts
26161
1
100000
80
ICE100/841/R/2P/ECO
4100
7300
5014
|
|
|
6,31,33,38,
51,76,78,100,101
For more complete product information visit www.sylvania.com
156
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
T12 Med Bipin
3:39 PM
Page 157
T8 Med Bipin
T12 RDC
T5 Mini Bipin
CFL 2Pin
CFL 4 Pin
SPECIALTY FLUORESCENT LAMPS
Diazo (SDB)
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
65
48
T12
47.78
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Med Bipin
24465
30
1000
F40T12/SDB/65W
|
|
|
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
115
Blacklight, Preheat Lamps (Starter Required)
These lamps are not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
15
T8
18
20
T12
22
T12
25
30
32
|
|
|
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
17.78
Med Bipin
21623
F15T8/350BL
24
7500
31,33,59,60,105
24
23.78
Med Bipin
22113
F20T12/350BL
24
9000
31,33,59,60,106
15
14.78
Med Bipin
21445
F15T12/350BL/500/PH
30
T8
18
17.78
Med Bipin
21703
F25T8/350BL/18in
24
7500
31,33,59,60,107
T8
36
35.78
Med Bipin
23113
F30T8/350BL
24
7500
31,33,59,60,109
T12
18
17.78
Med Bipin
21525
F18T12/350BL/700/PH
30
31,33,59,60,111
31,33,59,60,112
Blacklight, Rapid Start Lamps (No Starter Required)
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
40
T12
48
115
T12
48
|
|
|
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
47.78
Med Bipin
24922
F40/350BL
30
20000
2,30,31,33,56,60,64,110
45.91
Recessed DC
25251
FR48T12/350BL/VHO/180
30
10000
31,33,60,90,113
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
Blacklight Blue, Preheat Lamps (Starter Required)
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
4
T5
6
5.91
Mini Bipin
20425
F4T5/BLB
24
6000
31,33,59,60,99
8
T5
12
11.91
Mini Bipin
20825
F8T5/BLB
24
7500
31,33,59,60,99
15
T8
18
17.78
Med Bipin
21625
F15T8/BLB
6
7500
31,33,59,60,99
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
6
20000
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
|
|
|
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
Blacklight Blue, Rapid Start Lamps (No Starter Required)
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Base
Product
Number Ordering Abbreviation
40
48
Med Bipin
24026
T12
47.78
F40/BLB/RP
|
|
|
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
2,30,31,33,56,60,64,102
GERMICIDAL LAMPS
Germicidal Compact Fluorescent Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
7
T5
G23
23372
GCF7DS/G23/SE/OF
10
8000
31,33,45,47,50,82
9
T5
G23
23373
GCF9DS/G23/SE/OF
10
8000
31,33,45,47,50,82
11
T4
G23
23377
GCF11DS/G23/SE/OF
10
8000
31,33,45,47,50,82
18
T5
2G11
23378
GFT18DL/2G11/SE/OF
10
8000
31,33,36,48,74,82
24
T5
2G11
23379
GFT24DL/2G11/SE/OF
10
8000
31,33,36,48,74,82
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 160-165
157
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
CFL 4 Pin
Page 158
T5 Mini Bipin
T8 Med Bipin
T5 Single End, T6 Single End
T5 Single Pin
GERMICIDAL LAMPS
Germicidal Compact Fluorescent Lamps
41
Nominal
Wattage Bulb
36
Nominal
Length MOL
(in)
(in)
T6
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
2G11
23380
10
8000
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
GFT36DL/2G11/SE/OF
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
|
|
|
31,33,36,48,74,82
Germicidal, Preheat Lamps (Starter Required)
41
Nominal
Wattage Bulb
F
L
U
O
R
E
S
C
E
N
T
Nominal
Length MOL
(in)
(in)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
6
T5
Mini Bipin
23375
G6T5/OF
10
6000
31,33,45,57,82
8
T5
Mini Bipin
20811
G8T5/OF
24
6000
31,33,45,59,82
10
T8
Med Bipin
23374
G10T8/OF
10
6000
31,33,59,82
15
T8
Med Bipin
21612
G15T8/OF
24
7500
31,33,45,59,82
16
T5
4 PIN
23384
G10T5/4P/SE/OF
10
9000
31,33,59,82
Mini Bipin
23387
G20T5/G5/OF
10
9000
31,33,59,82
25
T5
Med Bipin
23376
G25T8/OF
10
8000
31,33,59,82
30
T8
Med Bipin
23112
G30T8/OF
24
7500
31,33,45,59,82
39
T5
4 PIN
23381
G36T5/4P/SE/OF
10
9000
31,33,57,82
Mini Bipin
23382
G36T5/G5/OF
10
9000
31,33,59,82
55
T5
Med Bipin
23388
G55T8/OF
10
8000
31,33,59,82
65
T5
4 PIN
23386
G64T5/4P/SE/OF
10
9000
31,33,82
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
|
|
|
Germicidal Instant Start Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
14
T5
Single Pin
23383
G14T5/SP/OF
10
8000
31,33,82
16
T5
Single Pin
23385
G10T5/SP/OF
10
9000
31,33,82
39
T5
Single Pin
23443
G36T5/SP/OF
10
9000
31,33,82
65
T5
Single Pin
23442
G64T5/SP/OF
10
9000
31,33,82
Base
Product
Number Ordering Abbreviation
Pkg
Qty
Avg Rated Life CCT
@3hrs/start (K)
|
|
|
Germicidal Amalgam Lamps
41
Nominal
Wattage Bulb
Nominal
Length MOL
(in)
(in)
Approx Lumens
Initial Mean Symbols &
CRI @25°C/77°F Footnotes
120
T6
4 PIN
23364
G120T6/4P/SE/OF
5
8000
31,33,82
190
T6
4 PIN
23365
G190T6/4P/SE/OF
5
8000
31,33,82
|
|
|
FLUORESCENT PREHEAT LAMP STARTERS
GLOSTAT Starters
47
Product
Number
Ordering Abbreviation
Pkg
Qty
Description
42812
FS-2
100
Fluorescent starter for use with F14, F15 and F20 preheat fluorescent lamps. UL, CSA
42901
FS-2/BL/2PK
12
Fluorescent starter for use with F14, F15 and F20 preheat fluorescent lamps, bulk pack with 2
starters. UL, CSA
44812
FS-4 100/CS
100
Fluorescent starter for use with F13, F30 and F40 preheat lamps. UL, CSA
For more complete product information visit www.sylvania.com
158
Symbols &
Footnotes
|
|
|
Symbols/Footnotes on page 160-165
055_FL_print.qxd
12/12/07
3:39 PM
Page 159
FLUORESCENT PREHEAT LAMP STARTERS
GLOSTAT Starters
47
Product
Number
Ordering Abbreviation
Pkg
Qty
44902
FS-4/BL/2PK
12
Fluorescent starter for use with F13, F30 and F40 preheat lamps, blister pack with 2 starters. UL,
CSA
45812
FS-5
100
Fluorescent starter for use with F4, F6 and F8 preheat fluorescent lamps. UL, CSA
45813
FS-5/BL/2PK
12
Fluorescent starter for use with F4, F6 and F8 preheat fluorescent lamps, blister pack with 2
starters. UL, CSA
43813
FS-12/BL/2PK
12
Fluorescent starter for use with FC12 Circline lamps when operated by preheat ballasts and F22T8
preheat lamps, blister pack with 2 starters. UL, CSA
42512
FS-25
100
Fluorescent starter for use with FC6 (20W) & FC8 (22W) Circline lamps when operated by preheat
ballasts; F25 and F18T8 preheat lamps. UL, CSA
42513
FS-25/BL/2PK
12
Fluorescent starter for use with FC6 (20W) & FC8 (22W) Circline lamps when operated by preheat
ballasts; F25 and F18T8 preheat lamps, blister pack with 2 starters. UL, CSA
Description
Symbols &
Footnotes
|
|
|
COP Starters With Cutout And Manual Reset
47
Product
Number
Ordering Abbreviation
Pkg
Qty
Description
42302
FS-20 (COP-20)
100
Fluorescent starter with cutout and manual reset for use with F15 & F20 preheat lamps. UL, CSA
44102
FS-40/400 (COP-40/400) 100
Symbols &
Footnotes
|
|
|
Fluorescent starter with cutout and manual reset for use with F40 preheat lamps. UL, CSA
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 160-165
159
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:39 PM
Page 160
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Symbol
Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
Rating given for 200mA operation.
This fluorescent lamp generates radiant energy which is most beneficial for plant propagation and enhances vegetative and reproductive
growth of many plants for home and commercial use.
This lamp or ballast meets minimum Federal efficiency standards.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
This lamp is a High Color Rendering Lamp
F
L
U
O
R
E
S
C
E
N
T
Footnote
Description
1
May be operated at 100 watts (1000MA) same as F84T12/HO.
2
Average life rating at 12 hours operation per start is 28,800 hours.
3
Due to their small diameter, T2 miniature fluorescent lamps operate at higher surface temperatures than other fluorescent lamps. To avoid
possible burns, do not touch the lamp during operration and allow sufficient cooling time before removing the lamp from the fixture. The typical bulb wall temperature during operation is 120 degrees at the ends. The maximum allowable bulb wall temperature is 150 degrees C. To
avoid electrical shock, turn electrical power off before removing or installing the lamp.
4
The 30,000 hour average rated of the OCTRON (R) XPS CURVALUME (R) lamp is based on operation at 3 hours per start by a dedicated
QUICKTRONIC(R) PSX ballast. If operated by other ballasts for T8 OCTRON lamps, life will be the same as that of the XP version of the lamp:
typically 24,000 hours for rapid or programmed rapid start operation and 18,000 hours for instant start operation at 3 hours per start.
5
The lamp lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 8,000
hours, 40% of 20,000 hours. It was used to allow comparison to standard OCTRON(R) lamps with an average rated life of 20,000 hours. The
lamp lumen maintenance factor at 40% of 24,000 hours, 9600 hours, would be 94%; the lamp lumen maintenance factor at 40% of 30,000
hours, 12000 hours, would be 93%.
6
The /2P version of the ICETRON lamp is supplied with a 24 inch lead wire terminated by a 2-Pin connector rather than the old 12 inch lead,
3-Pin connector design. The /2P versions are powered by QT1X100 ICE/UNV-T or QT1X150 ICE/UNV-T ballasts.
7
Recommended to be used on any F96 T8 Instant Start circuit. It is not recommended to be used: (1) at lamp ambient temperatures below 60
degrees F or in drafty locations, (2) on low power factor ballast, or (3) inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with the OCTRON FO96 SUPERSAVER 55 watt T8 lamp. Any of the above situations could result in
lamp starting and stabilization problems.
8
Current ballast design incorporates a modular 2-Pin connector plugin from the lamp. An adapter, NAED code 26240, is available to connect 3Pin lamp types to current (2-Pin) design ballasts.
9
This lamp may also be operated by the OSRAM SYLVANIA QUICKTRONIC(R) PSN ballast (.88 BF), or the QUICTRONIC PSX ballast (.71 BF).
10
The lumen maintenance factor used to determine the mean lumens value was 92%, measured at 40% of the average rated life, 15,000 hours.
The lumen maintenance factor at 4,000-4,800 hours (for comparison to F96T12 HO and F96T12 Slimline instant start lamps) is 93%.
11
Minimum starting temperature for DULUX EL lamps is 0 degrees F
12
For operation in fixtures designed only for 24 ", 30 watt, T-12 Fluorescent lamps.
13
Life rating is based on rapid start operation. Life rating on instant start operation is 15,000 hrs.
14
Caution: Although DURA-ONE lamps can be used with occupancy sensors that have a fluorescent volt-amp rating, DURA-ONE lamps cannot
be used on any other dimming circuits, emergency exit fixtures or lights, electronic timers, photocells, lighted switches or any other switches
that do not meet UL20 Sec. 7.6.15. In outdoor applications, use only in enclosed fixtures to avoid exposure to weather. Use only on 120V, 60
Hz circuits. Never disassemble or modify lamp. Install or remove unit from fixture by grasping plastic base. Best performance achieved when
operated at 77˚F (25˚C). Operating temperature range of DURA-ONE lamps is -20˚F/-29˚C to 122˚F/50˚C.
15
Service life (that amount of time where light output remains greater than or equal to 80% of initial lumens) is 16,000 hours for FP28/RED,
FP28/GREEN, FP54/RED/HO and FP54/GREEN/HO and 10,000 hours for FP28/BLUE and FP54/BLUE/HO.
16
The life of this lamp, operated on instant start electronic ballasts is 24,000 hours based on the industry standard life test standard of 3 hours
per start.
17
Recommended to be used on any F32 T8 instant start circuit. It is not recommended to be used: (1) with rapid Start circuits unless the open
circuit voltage is greater than 570V, (2) at lamp ambient temperatures below 70˚F or in drafty locations, (3) in air handling fixtures, (4) on
dimming ballasts, (5) on inverter operated emergency lighting systems unless any of the above equipment is specifically listed for 25W
lamps, or (6) below 60˚F starting temperature. Any of the above situations could result in lamp starting and stabilization problems or system
compatibility issues.
For more complete product information visit www.sylvania.com
160
055_FL_print.qxd
12/12/07
3:39 PM
Page 161
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote
Description
18
IF AN OPERATING LAMP IS EXPOSED TO TEMPERATURES BELOW 70˚F OR MOVING AIR (WIND, DRAFTS OR AIR FLOW FROM AN AIR
CONDITIONING OR VENTILATION SYSTEM) STRIATION, A RHYTHMIC PULSING PATTERN OF LIGHT RUNNING THE LENGTH OF THE TUBE
AND/OR A REDUCTION IN LIGHT OUTPUT MAY OCCUR. While visually disconcerting, neither behavior is damaging to lamp life and removing
the cause (draft or temperature) will return the lamp to normal operation.
19
The 36,000 hour average rated life of the FO32/800XPS/ECO OCTRON(R) lamp is based on operation at 3 hours per start on a QUICKTRONIC(R) programmed start ballast. If operated on other ballasts for T8 OCTRON lamps, lamp life will be 36,000 hours for programmed rapid
start operation and 24,000 hours for instant start operation at 3 hours per start.
20
The 36,000 hour average rated life of the FO32/800XP/ECO, FO30/800XP/SS/ECO, FO28/800XP/SS/ECO and FO32/25W/800XP/SS/ECO
OCTRON(R)lamps is based on operation at 3 hours per start on a QUICKTRONIC(R) programmed start ballast. If operated on other ballasts
for T8 OCTRON lamps, lamp life will be 36,000 hours for programmed rapid start operation and 24,000 hours for instant start operation at 3
hours per start.
21
The life rating of FO32/800/ECO OCTRON® lamps operated on rapid start ballasts is 30,000 hours. The life rating of FO32/800/ECO OCTRON
lamps operated on instant start ballasts is 24,000 hours.
22
Recommended only for use on 2-lamp, 30 watt rapid-start high power factor lead, indoor ballasts that meet ANSI standards. Not intended for
use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 25 watt lamps.
23
If an operating lamp is exposed to drafts or the ambient temperature falls below 60 degrees F, striation (a rhythmic pulsing pattern of light
running down the tube) and/or reduction in lamp brightness may occur. While visually disconcerting, neither behavior is damaging to the
lamp and removing the cause (draft or temperature) will return the lamp to normal operation.
24
Recommended for use on one or two lamp 40 watt rapid start, high power factor, lead, indoor ballasts that meet ANSI standards. Not intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 34 watt lamps.
25
Recommended for use on two lamp 40 watt rapid start, high power factor, lead indoor ballasts that meet ANSI standards. Not intended for
use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, (5) on inverter operated emergency lighting systems, or (6) on high frequency
electronic ballasts. Use one Thrift/Mate with one F40/SS in each two lamp circuit.
26
Recommended for use on one or two lamp high power factor, lead, instant-start, indoor ballasts that meet ANSI standards. Not intended for
use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 32 watt or 60 watt lamps.
27
Recommended for use on one or two lamp high power factor, lead, 8-foot lamp, high output, indoor ballasts that meet ANSI standards. Not
intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low powerfactor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 95 watt lamps.
28
Recommended for use on 2-lamp high power factor, lead, 8-foot lamp, very high output, indoor ballasts that meet ANSI standards. Not
intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless equipment is
specifically listed for use with 195 watt lamps.
29
Recommended for use on two-lamp high power factor, lead-lag, Preheat, indoor ballasts that meet ANSI standards and installed in open type
fixtures. Not intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations (unstable operation or starting difficulties may be experienced below 60 degrees F or in strong drafts); (2) on low power factor ballasts, reduced current, reduced light output
ballasts, dimming ballasts, or in inverter operated emergency lighting systems.
30
Average rated life is measured at 3 hours per start on 2-lamp, rapid start magnetic ballasts per IES recommended practice. Lamp life on single-lamp rapid start ballasts may be reduced.
31
Approximate initial lumens after 100 hours operation.
32
Recommended for use on one or two lamp 40 watt rapid start, high power factor, lead, indoor ballasts that meet ANSI standards. Not intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 34 watt lamps. Not to be used on electronic ballasts nor with any other impedance modifying
devices.
33
The life ratings of fluorescent lamps are based on 3 hr. burning cycles under specified conditions and with ballast meeting ANSI specifications. If burning cycle is increased, there will be a corresponding increase in the average hours life.
34
Average rated life is based on 3 hours per start operated on rapid start circuits. Average rated life is 7,500 hours on preheat circuits and
5,000 hours on instant start circuits.
35
The life rating of OCTRON and OCTRON Curvalume lamps operated on magnetic rapid start ballasts is 20,000 hours. The life rating of
OCTRON and OCTRON Curvalume lamps operated on instant start electronic ballasts is 15,000 hours.
For more complete product information visit www.sylvania.com
161
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:40 PM
Page 162
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
F
L
U
O
R
E
S
C
E
N
T
Footnote
Description
36
These lamps may also be operated on rapid start circuits. On rapid start circuits the 24 watt lamp operates at 27 watts and the 36 watt lamp
operated at 39 watts. Rated lamp life is unchanged.
37
Lumen output rated on high frequency operation. 60 HZ operation would result in lower lumen output.
38
Lumen output and life rated on high frequency operation.
39
DULUX F lamps can typically be operated on DULUX L and PENTRON HO ballasts of the same/similar wattage. Check with the ballast manufacturer to verify lamp/ballast compatibility.
40
Rule of Thumb for Compact Fluorescent Lamps: Divide wattage of incandescent lamp by 4 to determine approximate wattage of compact fluorescent lamp that will provide similar light output.
41
Guarded OCTRON lamp has plastic tube guard, which filters 95% of the UV emissions and provides shatter protection.
42
Rating for OSRAM SYLVANIA Circline lamps are based on operation in Rapid Start circuits. They will also operate on preheat circuits.
43
Gold OCTRON lamp has plastic tube guard which filters wavelengths less than 525nm and provides shatter protection.
44
Life rating of OCTRON XP lamps operated on instant start electronic ballasts is 18,000 hours based on the industry standard life test cycle of
3 hours per start.
45
Germicidal lamps can be operated on corresponding wattage preheat ballasts.
46
Amalgam compact fluorescent lamps provide at least 90% light output from 40-140 degrees F. Non-amalgam compact fluorescent lamps provide at least 90% light output from 60-100 degrees F in the base up position, the temperature range is narrower for horizontal or base down.
47
Minimum starting temperature: CF5: -22 degrees F; CF7: -4 degrees F; CF9: 14 degrees F; CF13DS: 14 degrees F; CF13DD: -4 degrees F;
CF18DD: 5 degrees F; CF18DT: -4 degrees F; CF26: 14 degrees F.
48
Minimum starting temperature is a function of the ballast; consult the ballast manufacturer.
49
Minimum starting temperature for DULUX EL lamps is 0˚ F, unless otherwise specified in product literature. .
50
2 pin CF lamps are not suitable for use in frequently cycled applications or with occupancy sensors. 2 pin CF lamps should never be installed
in 4 pin sockets regardless if lamp will fit.
51
Color and CRI at amalgam tip temperature of 149 degrees F (65 degrees C) for ICETRON 70 and ICETRON 100 and at 158 degrees F (70
degrees C) amalgam tip temperature for ICETRON 150.
52
OCTRON lamps should be operated only with magnetic rapid start ballasts designed to operate 265 mA, T-8 lamps or high frequency (electronic) ballasts that are either instant start, or rapid start, or programmed rapid start specifically designed to operate T8 lamps. OCTRON
lamps may be operated on instant start ballasts with ballast factors ranging from a minimum of 0.71 to a maximum of 1.20 at the nominal
ballast input voltage. When OCTRON lamps are operated in the instant start mode, the two wires or two contacts of each socket should be
connected to each other. They should then be connected to the appropriate ballast lead wire using National Electric Code techniques.
53
For operation on instant start circuits. Use only in fixtures equipped with Instant Start Ballasts.
54
Approximate length of OCTRON CURVALUME lamps is measured from base face to outside of glass bend.
55
For optimum performance OCTRON CURVALUME 1 5/8 inch leg spacing lamps in the 3000K, 3500K and 4100K color temperatures are now
available only in the 82CRI version (800 series). These lamps are made to the same color standards and may be used in combination with
other SYLVANIA OCTRON lamps to meet the needs of lighting installations where T8 lamps are used.
56
The "RS" designation has been eliminated to simplify the ordering abbreviation.
57
Preheat lamp, starter required.
58
Low temperature performance rated at 35 degrees F ambient.
59
Starter required.
60
These lamps are not intended and should not be used for diagnostic, therapeutic, or cosmetic purposes.
61
For use with 4,6 & 8 watt lamps.
62
For use with 13,30 & 40 watt lamps.
63
For use with 14,15 & 20 watt lamps.
64
40W Rapid Start Lamps may be used in starter operated fixtures designed for 40W preheat lamps. Life rating for preheat service is approximately 15,000 hours average.
65
For use with 22 watt Circline lamps, 25 watt Std. Lp., FC6 & F18T8.
66
For use with 32 watt Circline lamps, F22T8.
67
For use with 15 & 20 watt lamps.
68
For use with 20 watt lamps.
69
For use with 30 watt lamps.
70
For use with 40 watt lamps.
71
For use with 90 & 100 watt lamps.
72
For use with 90 & 100 watt lamps (4-Pin type).
For more complete product information visit www.sylvania.com
162
055_FL_print.qxd
12/12/07
3:40 PM
Page 163
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote
Description
73
For use with GL-1302 GRO-LUX fixture.
74
There is a NEMA supported, industry issue where T2, T4, and T5 fluorescent and compact fluorescent lamps operated on high frequency ballasts may experience an abnormal end-of-life phenomenon. This end-of-life phenomenon can resulting one or both of the following: 1. Bulb
wall cracking near the lamp base. 2. The lamp can overheat in the base area and possibly melt the base and socket. NEMA recommends that
high frequency compact fluorescent ballasts have an end-of-life shutdown circuit which will safely and reliably shut down the system in the
rare event of an abnormal end-of-life failure mode described above. The final requirements of this system are yet to be defined by ANSI. For
additional information refer to NEMA papers on their WEBSITE at www.NEMA.org.
75
When base pins or R.D.C. bases are horizontal, window opening is centered downward or upward.
76
SYLVANIA ECOLOGIC fluorescent lamps are designed to pass the Federal Toxic Characteristic Leaching Procedure (TCLP) criteria for classification as non-hazardous waste in most states. TCLP test results are available upon request. Lamp disposal regulations may vary, check your
local & state regulations. For more information, please visit www.lamprecycle.org
77
This 4-pin DULUX lamp has an internal end-of-life mechanism (EOL) that shuts down the lamp preventing abnormal end-of life failure modes.
This lamp was designed for use with high frequency ballasts that do not have their own end-of-life (lamp)sensing circuits, but it is also compatible with high frequency ballasts that have their own end-of-life (lamp) sensing circuits.
78
ICETRON diameter is the outside diameter of the ferrite coil. ICETRON MOL is the length from the outside edge of the mounting bracket on
one end to the outside edge of the mounting bracket on the opposite end.
79
DULUX Els meet CSA, FCC and UL requirements.
80
Caution: DULUX EL units cannot be used on dimming circuits, emergency exit fixtures or lights, electronic timers, photocells, lighted switches or any other switches that do not meet UL20 Sec. 7.6.15. In outdoor applications, use only in enclosed fixtures to avoid exposure to
weather. Use only on 120V, 60 Hz circuits. Never disassemble or modify lamp. Install or remove unit from fixture by grasping plastic base.
Best performance achieved when operated at 77degrees F (25 degrees C). 40 Watt lamp is designed for base down orientation only.
81
Caution: DULUX EL Circline units cannot be used on dimming circuits, emergency exit fixtures or lights, electronic timers, photocells or lighted switches. In outdoor applications, use only in enclosed fixtures to avoid exposure to weather. Use only on 120V, 60 Hz circuits.
82
WARNING: To prevent possible serious injury, eyes and skin should not be exposed to direct or reflected ultraviolet power emitted by this
lamp. This lamp is in Risk Group 3 per ANSI/IESNA RP-27.3-96. Adequate protection should be provided by clothing, gloves, opaque materials, and ordinary window glass. Although this lamp will operate in standard fluorescent fixtures, it should not be used for general lighting
applications.
83
Mean lumens at 8,000 hours (40% of 20,000 hours for comparison to standard OCTRON and F40 rapid start lamps). The lumen maintenance
factor at 40% of average rated life (9,600 hours) is 94%.
84
The lumen maintenance factor used to determine the mean lumens value was 90%, measured at 40% of the average rated life, 15,000 hours.
The lumen maintenance factor at 4,000-4,800 hours (for comparison to F96T12 HO and F96T12 Slimline instant start lamps) is 91%.
85
The lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 6000 hours,
40% of 15,000 hours. It was used to allow comparison to standard OCTRON(R) lamps with an average rated life of 15000 hours. The lamp
lumen maintenance factor at 40% of the 18,000 hour average rated life of this lamp, 7200 hours, would be 94%.
86
When base pins or R.D.C. bases are horizontal, window opening is centered to either side.
87
The lamp lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 8,000
hours, 40% of 20,000 hours. It was used to allow comparison to standard OCTRON(R) lamps with an average rated life of 20,000 hours. The
lamp lumen maintenance factor at 40% of the 24,000 hour average rated life of this lamp, 9600 hours, would be 94%.
88
Low temperature performance rated at 35 degrees F ambient.
89
Cool White lamp with 30 degree aperture (Power Beam).
90
Blacklight lamp with 180 degree reflector>
91
Labeled for cold temperature (below 60 degrees F) operation only per EPACT.
92
Under ideal conditions, an average rated life of 10,000 hours at 3 hours/start is possible.
93
The 30,000 hour average rated life of the FO17/800XPS/ECO and FO25/800XPS/ECO OCTRON(R) lamps is based on operation at 3 hours start
on a QUICKTRONIC(R) Programmed Start ballast. If operated on other ballasts for T8 OCTRON lamps, lamp life will be 30,000 hours for rapid
start operation, and 18,000 hours for instant start operation at 3 hours per start.
94
The lamp lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 8000
hours, 40% of 20,000 hours. It was used for comparison to standard OCTRON(R) lamps with an average rated life of 20,000 hours. The lamp
lumen maintenance factor at 40% of 24,000 hours, 9600 hours, would be 94%; the lamp lumen maintenance factor at 40% of 30,000 hours,
12,000 hours, would be 93%
95
Recommended to be used on any F32 T8 Instant Start circuit. It is not recommended to be used:(1) with Rapid Start circuits unless the open
circuit voltage is greater than 550V, (2) at lamp ambient temperatures below 60 degrees F or in drafty locations, (3) on dimming ballast or (4)
inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use with the OCTRON(R) SUPERSAVER(R) 28 or 30 watt, 4 foot or 30W U-bent T8 lamp. Any of the above situations could result in lamp starting and stabilization problems
For more complete product information visit www.sylvania.com
163
F
L
U
O
R
E
S
C
E
N
T
055_FL_print.qxd
12/12/07
3:40 PM
Page 164
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
F
L
U
O
R
E
S
C
E
N
T
Footnote
Description
96
SAFELINE lamps satisfy the criteria of having a non-shattering covering for prevention of glass and other lamp components in your product
by containment within the safety coating material. The covering must be intact or the lamp must be replaced to be in compliance. An onsite
inspector will require correction if the lamps are installed improperly or not maintained properly.
97
Average life rating at 12 hours operation per start is 18,000 hours.
98
SAFELINE lamps are intended for indoor use only. Lamps must be used in ambient temperatures below 135 degreed F. The coating is
designed to withstand constant operating temperatures up to 239 degrees F and has a melting point in excess of 500 degrees F. Lamps must
be used with sockets that provide adequate lamp pin to socket contact. Lamps must not be used with defective ballasts sockets, or fixtures
with improper wiring.
99
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.25 meters (10 inches) should be limited; for example exposure at 0.14m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
100
WARNING: ICETRON® Inductively Coupled Electrodeless Fluorescent lamp. Read these warnings and instructions before installing and using
this lamp. 1. This lamp operates at a higher temperature (130 C) than standard fluorescent lamps. To avoid the possibility of minor skin
burns, do not touch lamp or metal mounting brackets during operation and allow sufficient cooling time prior to servicing, handling, or
replacing lamp. 2. This lamp generates electric and magnetic fields during operation. The electric and magnetic fields generated by this lamp
during operation in typical lighting applicatons do not pose exposure risks relative to the limits documented in ANSI C95.1. 3. To prevent
electric shock, shut off the main power to the fixture and allow at least two minutes for ballast voltage to discharge before attempting to service or replace lamp. 4. To obtain optimum safety and system performance, use only with OSRAM SYLVANIA ballast. 5. To avoid potential
electric shock hazard, do not use lamp if wires or insulation are cut or pulled out of connector.
101
WARNING: ICETRON® Inductively Coupled Electrodeless Fluorescent lamp. Read these warnings and instructions before installing and using
this lamp. Instructions for Installation and Use. 1) To avoid premature lamp or ballast failure and ensure proper lamp, ballast, and system
performance, make sure lamp, ballast, and fixture are properly installed. Electrical interconnects, electrical grounds, thermal management,
and heatsinking specifications and requirements must be fully adhered to in all applications. (See OSRAM SYLVANIA ICETRON DESIGN
GUIDE.) 2. Do not alter the electrical connector on lamp and/or ballast. To do so may adversely affect lamp operation, ballast life, and/or
emission of EMI (electromagnetic interference). 3. This product may cause interference with radios, cordless telephones, and remote control
devices. If interference occurs, relocate the radios, cordless telephones, and/or remote control devices away from this product.
102
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.14m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
103
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.35 meters (14 inches) should be limited; for example exposure at 0.25m (10 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
104
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.45 meters (18 inches) should be limited; for example exposure at 0.3m (12 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
105
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.55 meters (22 inches) should be limited; for example exposure at 0.4m (16 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
106
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.65 meters (26 inches) should be limited; for example exposure at 0.45m (18 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
107
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.7 meters (28 inches) should be limited; for example exposure at 0.54m (20 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
For more complete product information visit www.sylvania.com
164
055_FL_print.qxd
12/12/07
3:40 PM
Page 165
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote
Description
108
Average life rating at 12 hours operation per start is 15,000 hours.
109
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.75 meters (30 inches) should be limited; for example exposure at 0.55m (22 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
110
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
1.0 meters (39 inches) should be limited; for example exposure at 0.64m (24 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
111
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.6 meters (24 inches) should be limited; for example exposure at 0.45m (18 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
112
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.8 meters (31 inches) should be limited; for example exposure at 0.55m (22 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
113
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
2.0 meters (79 inches) should be limited; for example exposure at 1.4m (55 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
114
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.2m (8 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
115
CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.15m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
116
A fluorescent jacketed lamp consists of a T12 (1 1/2" diameter) lamp enclosed inside a T14.5 (1 13/16" diameter) glass jacket. A jacketed fluorescent lamp operates efficiently over a wide range of climatic conditions, including extremes of cold and strong wind in which an unjacketed (bare) lamp would be inefficient or inoperable. The jacket size provides the clearance necessary to minimize damaging lamp-jacket contact; narrow bands of rubber placed between the lamp and the jacket further prevent contact. A weather-tight seal is formed by neoprene rubber end caps.
117
Mean lumens at 7,200 hours (40% of 18,000 hour average rated life) equal 4,371. For comparison to an F72T12 Slimline lamp with an average rated life of 12,000 hours use a mean lumen value of 4418 based on 95% lumen maintenance at 4,800 hours,(40% of 12,000 hours).
118
Use only with electronic ballasts which have been specifically designed to operate T2 miniature fluorescent lamps and to reliably and safely
control all lamp operating modes including end-of-lamp-life sensing circuitry. If a non-conforming ballast is used, very high temperatures
(350 degrees C typical) may be generated at the ends of the lamp especially during end-of-lamp-life operation, causing the lamp to crack and
resulting in potential fire, electrical shock, or burn hazards.
119
The life rating of FO32/700/ECO OCTRON® lamps operated on rapid start ballasts is 25,000 hours. The life rating of FO32/700/ECO OCTRON
lamps operated on instant start ballasts is 24,000 hours.
For more complete product information visit www.sylvania.com
165
F
L
U
O
R
E
S
C
E
N
T
100_cref.qxd
12/12/07
12:32 PM
Page 166
Manufacturers’ Cross Reference Guide (continued)
FLUORESCENT LAMPS
F
L
U
O
R
E
S
C
E
N
T
SYLVANIA
GE
PHILIPS
OCTRON®
FO17/830/ECO
FO17/835/ECO
FO17/841/ECO
F17T8/SPX30/ECO
F17T8/SPX35/ECO
F17T8/SPX41/ECO
F17T8/TL830/ALTO
F17T8/TL835/ALTO
F17T8/TL841/ALTO
F17T8/TL850/ALTO
F17T8/XL/SPX30/ECO
F17T8/XL/SPX35/ECO
F17T8/XL/SPX41/ECO
F17T8/XL/SPX50/ECO
F17T8/XL/SPX65/ECO
F17T8/TL830/PLUS/ALTO
F17T8/TL835/PLUS/ALTO
F17T8/TL841/PLUS/ALTO
F17T8/TL850/PLUS/ALTO
F17T8/TL865 /PLUS/ALTO
F25T8/SPX30/ECO
F25T8/SPX35/ECO
F25T8/SPX41/ECO
F25T8/TL830/ALTO
F25T8/TL835/ALTO
F25T8/TL841/ALTO
F25T8/TL850/ALTO
F25T8/XP/SPX30/ECO
F25T8/XP/SPX35/ECO
F25T8/XP/SPX41/ECO
F25T8/XP/SPX50/ECO
F25T8/XP/SPX65/ECO
F25T8/TL830/PLUS/ALTO
F25T8/TL835/PLUS/ALTO
F25T8/TL841/PLUS/ALTO
F25T8/TL850/PLUS/ALTO
F25T8/TL865/PLUS/ALTO
FO17/827/XP/ECO
FO17/830/XP/ECO
FO17/835/XP/ECO
FO17/841/XP/ECO
FO17/850/XP/ECO
FO17/865/XP/ECO
FO17/830XPS/ECO
FO17/835XPS/ECO
FO17/841XPS/ECO
FO25/830/ECO
FO25/835/ECO
FO25/841/ECO
FO25/827/XP/ECO
FO25/830/XP/ECO
FO25/835/XP/ECO
FO25/841/XP/ECO
FO25/850/XP/ECO
FO25/865/XP/ECO
FO25/830XPS/ECO
FO25/835XPS/ECO
FO25/841XPS/ECO
FO32/25W/830XP/SS/ECO
FO32/25W/835XP/SS/ECO
FO32/25W/8410XP/SS/ECO
FO32/25W/850XP/SS/ECO
FO28/830XP/SS/ECO
FO28/835XP/SS/ECO
FO28/841XP/SS/ECO
FO28/850XP/SS/ECO
FO30/830XP/SS/ECO
FO30/835XP/SS/ECO
FO30/841XP/SS/ECO
FO30/850XP/SS/ECO
FO32/730/ECO
FO32/735/ECO
FO32/741/ECO
FO32/750/ECO
FO32/765/ECO
FO32/730/XP/ECO
FO32/735/XP/ECO
FO32/741/XP/ECO
FO32/830/ECO
FO32/835/ECO
FO32/841/ECO
FO32/850/ECO
FO32/827/XP/ECO
FO32/830/XP/ECO
FO32/835/XP/ECO
FO32/841/XP/ECO
FO32/850/XP/ECO
FO32/865/XP/ECO
FO32/830XPS/ECO
FO32/835XPS/ECO
FO32/841XPS/ECO
FO32/830XPS/ECO
FO32/835XPS/ECO
FO32/841XPS/ECO
FO32/850XPS/ECO
FO32/865XPS/ECO
F28T8/SP30UMX/ECO
F28T8/SP35UMX/ECO
F28T8/SP41UMX/ECO
F28T8/SP50UMX/ECO
F32T8XL/SP30/WM/ECO
F32T8XL/SP35/WM/ECO
F32T8XL/SP41/WM/ECO
F32T8XL/SP50/WM/ECO
F32T8/SP30/ECO
F32T8/SP35/ECO
F32T8/SP41/ECO
F32T8/SP50/ECO
F32T8/SP65/ECO
F32T8/XL/SP30/ECO
F32T8/XL/SP35/ECO
F32T8/XL/SP41/ECO
F32T8/SPX30/ECO
F32T8/SPX35/ECO
F32T8/SPX41/ECO
F32T8/SPX50/ECO
F32T8/XL/SPX30/ECO
F32T8/XL/SPX35/ECO
F32T8/XL/SPX41/ECO
F32T8/XL/SPX50/ECO
F32T8/XL/SPX65/ECO
F32T8SXL/SPX30/ECO
F32T8SXL/SPX35/ECO
F32T8SXL/SPX41/ECO
F32T8/XL/SPX30/HL/ECO
F32T8/XL/SPX35/HL/ECO
F32T8/XL/SPX41/HL/ECO
F32T8/XL/SPX50/HL/ECO
For more complete product information visit www.sylvania.com
166
F32T8/ADV830/XEW/LL/ALTO 25Watt
F32T8/ADV835/XEW/LL/ALTO 25Watt
F32T8/ADV841/XEW/LL/ALTO 25Watt
F32T8/ADV850/XEW/LL/ALTO 25Watt
F32T8/ADV830/EW/LL/ALTO 28Watt
F32T8/ADV835/EW/LL/ALTO 28Watt
F32T8/ADV841/EW/LL/ALTO 28Watt
F32T8/ADV850/EW/LL/ALTO 28Watt
F32T8/ADV830/EW/LL/ALTO 30Watt
F32T8/ADV835/EW/LL/ALTO 30Watt
F32T8/ADV841/EW/LL/ALTO 30Watt
F32T8/ADV850/EW/LL/ALTO 30Watt
F32T8/TL730/ALTO
F32T8/TL735/ALTO
F32T8/TL741/ALTO
F32T8/TL750/ALTO
F32T8/TL730/PLUS/ALTO
F32T8/TL735/PLUS/ALTO
F32T8/TL741/PLUS/ALTO
F32T8/TL750/PLUS/ALTO
F32T8/TL830/ALTO
F32T8/TL835/ALTO
F32T8/TL841/ALTO
F32T8/TL850/ALTO
F32T8/TL830 PLUS/ALTO
F32T8/TL835 PLUS/ALTO
F32T8/TL841 PLUS/ALTO
F32T8/TL850 PLUS/ALTO
F32T8/TL865 PLUS/ALTO
F32T8/ADV830/ALTO
F32T8/ADV835/ALTO
F32T8/ADV841/ALTO
F32T8/ADV850/ALTO
100_cref.qxd
12/12/07
12:32 PM
Page 167
Manufacturers’ Cross Reference (continued)
FLUORESCENT LAMPS
SYLVANIA
OCTRON®
FO40/830/ECO
FO40/835/ECO
FO40/841/ECO
FO40/830/XP/ECO
FO40/835/XP/ECO
FO40/841/XP/ECO
FO96/830XP/SS/ECO
FO96/835XP/SS/ECO
FO96/841XP/SS/ECO
FO96/830/ECO
FO96/835/ECO
FO96/841/ECO
FO96/850/ECO
FO96/830/XP/ECO
FO96/835/XP/ECO
FO96/841/XP/ECO
FO96/850/XP/ECO
FO96/835/HO
FO96/841/HO
OCTRON® CURVALUME®
FBO16/830
FBO16/835
FBO16/841
FBO16/865/XP
FBO24/830
FBO24/835
FBO24/841
FBO31/830
FBO31/835
FBO31/841
FBO29/830/XP/SS/ECO
FBO29/835/XP/SS/ECO
FBO29/841/XP/SS/ECO
FBO31/830/XP/ECO
FBO31/835/XP/ECO
FBO31/841/XP/ECO
FBO30/830/XP/6/SS/ECO
FBO30/835/XP/6/SS/ECO
FBO30/841/XP/6/SS/ECO
FBO32/830/6/ECO
FBO32/835/6/ECO
FBO32/841/6/ECO
FBO32/830/6/XP/ECO
FBO32/835/6/XP/ECO
FBO32/841/6/XP/ECO
PENTRON® & PENTRON® HO
FP14/830/ECO
FP14/835/ECO
FP14/841/ECO
FP14/865/ECO
FP21/830/ECO
FP21/835/ECO
FP21/841/ECO
FP21/865/ECO
FP28/830/ECO
FP28/835/ECO
FP28/841/ECO
FP21/850/ECO
FP21/865/ECO
FP35/830/ECO
FP35/835/ECO
GE
PHILIPS
F40T8/SPX30
F40T8/SPX35
F40T8/SPX41
F96T8/XL/SP30/WM
F96T8/XL/SP35/WM
F96T8/XL/SP41/WM
F96T8/SPX30
F96T8/SPX35
F96T8/SPX41
F96T8/SPX50
F96T8/XL/SPX30
F96T8/XL/SPX35
F96T8/XL/SPX41
F96T8/XL/SPX50
F96T8/SPX30/HO
F96T8/SPX35/HO
F96T8/SPX41/HO
F40T8/TL830/ALTO
F40T8/TL835/ALTO
F40T8/TL841/ALTO
-
F31T8/SPX30/U
F31T8/SPX35/U
F31T8/SPX41/U
-
F32T8/SPX30/U/6
F32T8/SPX35/U/6
F32T8/SPX41/U/6
F14W/T5/830/ECO
F14W/T5/835/ECO
F14W/T5/841/ECO
F14W/T5/850/ECO
F14W/T5/865/ECO
F21W/T5/830/ECO
F21W/T5/835/ECO
F21W/T5/841/ECO
F21W/T5/850/ECO
F21W/T5/865/ECO
F28W/T5/830/ECO
F28W/T5/835/ECO
F28W/T5/841/ECO
F28W/T5/850/ECO
F28W/T5/865/ECO
F35W/T5/830/ECO
F35W/T5/835/ECO
F96T8/TL830/ALTO
F96T8/TL835/ALTO
F96T8/TL841/ALTO
F96T8/TL850/ALTO
F96T8/TL830PLUS/ALTO
F96T8/TL835PLUS/ALTO
F96T8/TL841PLUS/ALTO
F96T8/TL850PLUS/ALTO
F96T8/TL830/HO/PLUS
F96T8/TL835/HO/PLUS
F96T8/TL841/HO/PLUS
F
L
U
O
R
E
S
C
E
N
T
-
-
FB32T8/TL830/6/ALTO
FB32T8/TL835/6/ALTO
FB32T8/TL841/6/ALTO
FB32T8/TL850/6/ALTO
F14T5/830/ALTO
F14T5/835/ALTO
F14T5/841/ALTO
F21T5/830/ALTO
F21T5/835/ALTO
F21T5/841/ALTO
F28T5/830/ALTO
F28T5/835/ALTO
F28T5/841/ALTO
F35T5/830
F35T5/835
For more complete product information visit www.sylvania.com
167
100_cref.qxd
12/12/07
12:32 PM
Page 168
Manufacturers’ Cross Reference Guide (continued)
FLUORESCENT LAMPS
SYLVANIA
OCTRON® CURVALUME®
FP35/841/ECO
FP24/830/HO/ECO
FP24/835/HO/ECO
FP24/841/HO/ECO
FP39/830/HO/ECO
FP39/835/HO/ECO
FP39/841/HO/ECO
F
L
U
O
R
E
S
C
E
N
T
FP54/830/HO/ECO
FP54/835/HO/ECO
FP54/841/HO/ECO
FP54/850/HO/ECO
FP54/865/HO/ECO
FP54/835/C/HO/ECO
FP54/841/C/HO/ECO
FP54/850/C/HO/ECO
FP80/830/HO/ECO
FP80/835/HO/ECO
FP80/841/HO/ECO
PENTRON® CIRCLINE
FPC22/830
FPC22/835
FPC22/841
FPC40/830
FPC40/835
FPC40/841
FPC55/830/HO
FPC55/835/HO
FPC55/841/HO
F40 TYPES (STD & SS)
F34/D30/SS/ECO
F34/D35/SS/ECO
F34/D41/SS/ECO
F34/D830/SS/ECO
F34/D835/SS/ECO
F34/D841/SS/ECO
F40/D30/ECO
F40/D35/ECO
F40/D41/ECO
F40/D830/ECO
F40/D835/ECO
F40/D841/ECO
CURVALUME® 3"
CURVALUME® 6"
FB34/D30/6/SS
FB34/D35/6/SS
FB34/D41/6/SS
FB40/D30/6
FB40/D30/6
FB40/D41/6
FB40/D830/6
-
GE
PHILIPS
F35W/T5/841/ECO
F35W/T5/850/ECO
F35W/T5/865/ECO
F24W/T5/830/ECO
F24W/T5/835/ECO
F24W/T5/841/ECO
F24W/T5/850/ECO
F24W/T5/865/ECO
F39W/T5/830/ECO
F39W/T5/835/ECO
F39W/T5/841/ECO
F39W/T5/850/ECO
F39W/T5/865/ECO
F54W/T5/830/ECO
F54W/T5/835/ECO
F54W/T5/841/ECO
F54W/T5/850/ECO
F54W/T5/865/ECO
F35T5/841
F80W/T5/830/ECO
F80W/T5/835/ECO
F80W/T5/841/ECO
F54W/T5/850/ECO
F54W/T5/865/ECO
F80T5/830/HO
F80T5/835/HO
F80T5/841/HO
F34/SP30/RS/WM/ECO
F34/SP35/RS/WM/ECO
F34/SP41/RS/WM/ECO
F34/SPX30/RS/WM/ECO
F34/SPX35/RS/WM/ECO
F34/SPX41/RS/WM/ECO
F40/SP30/RS/ECO
F40/SP35/RS/ECO
F40/SP41/RS/ECO
F40/SPX30/RS/ECO
F40/SPX35/RS/ECO
F40/SPX41/RS/ECO
F40/XL/SP30, 35, 41
F40/XL/SPX30, 35, 41, 50
F40/SP30/U/3
F40/SP41/U/3
F40/SP30/U/6
F40/SP35/U/6
F40/SP41/U/6
F40/SPX30/U/6
F40/SPX35/U/6
-
For more complete product information visit www.sylvania.com
168
F24T5/830/HO/ALTO
F24T5/835/HO/ALTO
F24T5/841/HO/ALTO
FP39/830/HO/ECO/ALTO
FP39/835/HO/ECO/ALTO
FP39/841/HO/ECO/ALTO
F54T5/830/HO/ALTO
F54T5/835/HO/ALTO
F54T5/841/HO/ALTO
F54T5/850/HO/ALTO
F54T5/865/HO/ALTO
TL5C 22W/830
TL5C 22W/831
TL5C 22W/832
TL5C 40W/833
TL5C 40W/834
TL5C 40W/835
TL5C 55W/833
TL5C 55W/834
TL5C 55W/835
F34/830/RS/EW/ALTO
F34/835/RS/EW/ALTO
F34/841/RS/EW/ALTO
F34/850/RS/EW/ALTO
F40/SPEC30/RS/ALTO
F40/SPEC35/RS/ALTO
F40/SPEC41/RS/ALTO
F40/830/8RS/ALTO
F40/835/RS/ALTO
F40/841/RS/ALTO
FB34/SPEC30/6/EW/ALTO
FB34/SPEC35/6/EW/ALTO
FB34/SPEC41/6/EW/ALTO
FB40/SPEC30/6/ALTO
FB40/SPEC35/6/ALTO
FB40/SPEC41/6/ALTO
FB40/30U/6/ALTO
FB40/35U/6/ALTO
FB40/41U/6/ALTO
100_cref.qxd
12/12/07
12:32 PM
Page 169
Manufacturers’ Cross Reference (continued)
FLUORESCENT LAMPS
SYLVANIA
SLIMLINE
F96T12/D30/SS/ECO
F96T12/D35/SS/ECO
F96T12/D41/SS/ECO
F96T12/D830/SS/ECO
F96T12/D835/SS/ECO
F96T12/D841/SS/ECO
F96T12/D30/ECO
F96T12/D35/ECO
F96T12/D41/ECO
F96T12/D830/ECO
F96T12/D835/ECO
F96T12/D841/ECO
HIGH OUTPUT
F72T12/D830/HO
F96T12/D35/HO/SS
F96T12/D41/HO/SS
F96T12/D830/HO/SS
F96T12/D835/HO/SS
F96T12/D841/HO/SS
F96T12/D30/HO
F96T12/D35/HO
F96T12/D41/HO
F96T12/D830/HO
F96T12/D835/HO
F96T12/D841/HO
APPLIANCE
F18T8CW/K24
F18T8CW/K26
F18T8CW/K28
F18T8CW/K30
F18T8/D/K26
OTHER RAPID START
F25T12/D30/RS/SS
F25T12/D35/RS/SS
F30T12/D35/RS
F30T12/D41/RS
F30T12/D830/RS
F30T12/D835/RS
GE
F96T12/SP35/WMP
F96T12/SP30/WM/ECO
F96T12/SP35/WM/ECO
F96T12/SP41/WM/ECO
F96T12/SPX30/WM/ECO
F96T12/SPX35/WM/ECO
F96T12/SPX41/WM/ECO
F96T12/XL/SP35/WM
F96T12/XL/SP41/WM
F96T12/SP30/ECO
F96T12/SP35/ECO
F96T12/SP41/ECO
F96T12/SPX30/ECO
F96T12/SPX35/ECO
F96T12/SPX41/ECO
F96T12/XL/SP35, 41
F96T12/XL/SPX35, 41, 50
F72T12/SPX30/HO
F96T12/SP35/HO/WM
F96T12/SP41/HO/WM
F96T12/SPX830/HO/WM
F96T12/SPX35/HO/WM
F96T12/SPX41/HO/WM
F96T12/SP30/HO
F96T12/SP35/HO
F96T12/SP41/HO
F96T12/SPX830/HO
F96T12/SPX35/HO
F96T12/SPX41/HO
PHILIPS
-
F96T12/830/EW/ALTO
F96T12/835/EW/ALTO
F96T12/841/EW/ALTO
-
F
L
U
O
R
E
S
C
E
N
T
F96T12/830/ALTO
F96T12/835/ALTO
F96T12/841/ALTO
F72T12/30U/HO
F96T12/830/HO/EW/ALTO
F96T12/835/HO/EW/ALTO
F96T12/841/HO/EW/ALTO
F96T12/830/HO/ALTO
F96T12/835/HO/ALTO
F96T12/841/HO/ALTO
F24"T8/CW/4
F26"T8/CW/4
F28"T8/CW/4
F30"T8/CW/4
-
F16T8/CW/26
F17T8/CW/28
F18T8/CW/30/ALTO
-
F25T12/SP30/RS/WM
F25T12/SP35/RS/WM
F30T12/SP35/RS
F30T12/SP41/RS
F30T12/SPX30/RS
F30T12/SPX35/RS
F30T12/SPEC35/RS
F30T12/SPEC41/RS
F30T12/30U/RS
F30T12/35U/RS
For more complete product information visit www.sylvania.com
169
100_cref.qxd
12/12/07
12:32 PM
Page 170
Notes:
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
170
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 171
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
SYLVANIA
QUICKTRONIC ®
Electronic & Magnetic Ballasts
OSRAM
OPTOTRONIC ®
LED Power Supplies
171
PLG_graycale_2008_FINAL.qxd:Empty
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
12/18/07
10:43 AM
Page 172
The System is the Solution
QUICKTRONIC® High Efficiency
High Efficiency Series products are
energy-saving electronic T8 ballasts
that save additional 6% (2 to 5 watts)
over standard electronic ballasts. Features
also include <10%THD and Universal
Voltage. SYLVANIA QUICKTRONIC
High Efficiency (QHE) ballast operate
OCTRON® T8 lamps with maximum
efficacy and high lumen output, and
provides 30-50% energy savings when
compared to F40T12 magnetic systems.
I High Efficiency Systems over 90%
efficient (maximize energy savings)
I Over 100 LPW (lumens/watt) with
OCTRON SUPERSAVER® lamps
OSRAM SYLVANIA is the global leader in lighting systems.
The most important trend in lighting technology is the move toward
systems … we started this trend with
ballast combinations.
OSRAM SYLVANIA has the competitive advantage with years of
experience in designing, developing and supporting integrated
systems — both in ballasts and lamps. Our global network of design
and manufacturing brings ballast and lamp knowledge together to
produce innovative and cost-effective energy saving systems.
• Committed to providing energy efficient ballasts & lamps
• Our innovative system solutions exceed customer expectations
• New energy saving, higher efficiency, lower power systems
• These systems are covered by our QUICK 60+® warranty, the
first and most comprehensive system warranty in the industry
I Lowest power T8 Instant Start Systems
I Same Light, Less Power
Universal Voltage (120-277V)
Universal voltage models operate from
120-277 Volts, eliminating “incorrect line
voltage” wiring errors and reducing the
number of models in inventory by half.
QUICKTRONIC
T8 Instant Start <20% THD Products.
172
,
a family of optimally balanced energy saving lamps and electronic
QUICKTRONIC Professional
Professional Series products incorporate
one or more value added features such as
<10%THD, PROStart® Programmed Rapid
Start, Universal Voltage and QUICKSENSE®
end-of–lamp-life sensing.
Complete performance data is available
in the SYLVANIA QUICKTRONIC
Electronic Ballast Technology &
Specification Guide and at
www.sylvania.com.
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 173
Table of Contents
QUICKTRONIC Ballasts for T5HO, T5, DL40, T4 Systems
QUICKTRONIC® Electronic Ballasts . . . . . . . . . . . . . . . .176-184
Professional T5HO PROStart
<10% THD Universal Voltage Normal BF . . . . . . . . . . . . . . . .181
LED Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Discontinued Electronic Ballasts/Replacement List . . . .186-187
QUICKCROSS Electronic Mfrs. Cross Reference . . . . . .188-193
Fluorescent & HID Magnetic Ballasts
with Competitive Mfrs. Cross Reference . . . . . . . . . .194-205
QUICKTRONIC Electronic Ballasts
QUICKTRONIC Instant Start Ballasts
for OCTRON® T8 Lamps
High Efficiency T8 Instant Start
Universal Voltage Low BF . . . . . . . . . . . . . . . . . . . . . . . . . . . .176
High Efficiency T8 Instant Start
Universal Voltage Normal BF . . . . . . . . . . . . . . . . . . . . . . . . .176
High Efficiency T8 Instant Start
Universal Voltage High BF . . . . . . . . . . . . . . . . . . . . . . . . . . .176
Professional T5 PROStart
<10% THD Universal Voltage Normal BF . . . . . . . . . . . . . . . .181
Professional T5HO PROStart
<10% THD High Ambient Universal Voltage Normal BF . . . .181
Professional T5HO PROStart
<10% THD High Ambient 347-480 Volt Normal BF . . . . . . .181
High Efficiency Instant Start DL40 (40TT5)
<10% THD Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
Professional PROStart DL40(40WTT5)
<10% THD Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
Professional PROStart T4 Compact
<10% THD Universal Voltage Dual Entry Normal BF . . . . . . .182
QUICKTRONIC® DIMMING & DALI Ballasts
Professional T8 Instant Start
Universal Voltage Low BF . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
POWERSENSE® T8 DIMMING Universal Voltage
(2 wire and 0-10 volt controllable) . . . . . . . . . . . . . . . . . . . . . .182
Professional T8 Instant Start
Universal Voltage Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . .177
HELIOS™ T8 Dimming (277V)
(0-10Vdc controllable) High BF . . . . . . . . . . . . . . . . . . . . . . . .182
Professional T8 Instant Start
Universal Voltage High BF . . . . . . . . . . . . . . . . . . . . . . . . . . .177
High Efficiency T8 Instant Start Universal Voltage
UL Type CC - Lamp Striation Control/LSC Normal BF . . . .179
QUICKTRONIC PROStart® Ballasts
for OCTRON T8 Lamps
Xtreme Systems PROStart PSX
Universal Voltage Low BF . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
SUPERSAVER® Xtreme Systems PROStart PSX
Universal Voltage Low BF . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
PROStart PSN
Universal Voltage Normal BF . . . . . . . . . . . . . . . . . . . . . . . . .178
High Efficiency T8 PROStart Universal Voltage
90°C Case Temperature High BF . . . . . . . . . . . . . . . . . . . . . .179
QUICKTRONIC Ballasts for 8 Foot Lamps (T8)
High Efficiency Instant Start 96T8(59W)
Universal Voltage Low/Normal/High BF . . . . . . . . . . . . . . . . .179
Professional Instant Start 96T8(59W)
Universal Voltage Normal BF . . . . . . . . . . . . . . . . . . . . . . . .179
High Efficiency PROStart 86T8/HO
90°C Case Temperature Universal Voltage Normal BF . . . . . .179
QUICKTRONIC Ballasts for
CANADIAN 347Volt T8 Systems
High Efficiency T8 Instant Start
<10% THD 347 V CANADA Low/Normal BF . . . . . . . . . . . .180
Standard (<20% THD) & Professional (<10% THD)
T8 and 8 foot T8 Instant Start
347 V CANADA Low/Normal/High BF . . . . . . . . . . . . . . . . .180
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
CFL KITS PROStart T4 Compact
<10% THD Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . .182
POWERSENSE T5 Dimming Universal Voltage
(2 wire and 0-10Vdc controllable) . . . . . . . . . . . . . . . . . . . . . .182
Professional HELIOS T5HO DIMMING
(0-10 volt controllable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
Professional T8 DALI Digital Dimming
(100-1% range) Universal Voltage . . . . . . . . . . . . . . . . . . . . . .183
Professional T5HO DALI Digital Dimming
(100-1% range) Universal Voltage . . . . . . . . . . . . . . . . . . . . . .183
Professional T5 DALI Digital Dimming
(100-1% range) Universal Voltage . . . . . . . . . . . . . . . . . . . . . .183
Professional CF/DL40 DALI Digital Dimming
(100-3% range) Universal Voltage . . . . . . . . . . . . . . . . . . . . . .183
QUICKTRONIC Ballasts for
8 foot T12 lamps & F40T12 Systems
Instant Start 96T12 and 96T12HO Rapid Start
<20% THD Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
Professional 40T12 Rapid Start
<10% THD Normal BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
QUICKTRONIC Specialty Systems
ICETRON®
<15% THD Type 1 and Type 2 Universal Voltage . . . . . . . . . .184
T2 FM Fluorescent Subminiature
. . . . . . . . . . . . . . . . . . . . . .184
Electronic Metal Halide (MH) . . . . . . . . . . . . . . . . . . . . . . . . . .184
LED Systems Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
OPTOTRONIC® Electronic Constant Current
LED Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
OPTOTRONIC Electronic LED
10.5 Volt Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
OPTOTRONIC Electronic LED
24 Volt Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
OPTOTRONIC Electronic
LED RGB Control Modules . . . . . . . . . . . . . . . . . . . . . . . . . . .185
OPTOTRONIC Electronic
LED Dimming Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
173
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 174
The Original System Solution
Key System Features:
The first matched T8 lamp and ballast systems
for optimized performance and longer life.
• Lowest power T8 Instant Start Systems
• Over 100 LPW (lumens/watt) with OCTRON®
QUICKTRONIC® High Efficiency
Type CC & Lamp Striation Control (LSC) Models
Offer the same energy
SUPERSAVER lamps
• Provides 30-50% energy savings when compared to
F40T12 Magnetic Systems
• QHE/SS Systems provide up to 25% savings compared
to standard T8 systems
saving benefits as the High
Efficiency QHE ballasts with
• Universal Input Voltage (120-277)
two additional advantages:
(Commercial Cabinet)
Rating: New microcon-
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
% Relative Light Output
% System Wattage
120%
• Meets UL Type CC
100%
troller circuity reduces
arcing caused by loose
80%
or improper lamp pin
60%
100% 100%
112% 5%
Energy
Savings
95%
106%
102%
12%
Energy
Savings
88%
19%
Energy
Savings
81%
92% 25%
Energy
Savings
75%
to socket connections.
• Lamp Striation Control, (LSC): LSC circuitry minimizes
lamp striations/strobing that can occur at lower
temperatures and especially in T8 energy saving lamps.
(Please consult manufacturers for additional details.)
Banded Packaging
2-FO32/700
QTP 2x32 ISN
2-FO32/800/XP
QHE 2x32 ISN-1
2-FO30/SS
QHE 2x32 ISN-1
2-FO28/SS
QHE 2x32 ISN-1
2-FO25/SS
QHE 2x32 ISN-1
• Exclusive lamp warranty for occupancy sensor applications
SUPERSAVER® Xtreme Systems
ballast sales
• Easily removable bands
0%
A programmed rapid starting method for
fluorescent lamps that achieves up to
100,000 switching cycles which is ideal
for use on occupancy sensors.
replaced the shrink-wrap
product for added benefits:
• Distributor friendly; easy
stocking for individual
• Reduce waste
20%
PROStart®
New Banded Packaging has
• Contractor friendly;
easy handling; no
tangled wires
40%
Removable
Bands
New High Efficiency QUICKTRONIC PROStart PSX Universal
Voltage ballasts when combined with OCTRON SUPERSAVER
energy saving high performance T8 lamps provide the lowest
power PROStart T8 systems available.
Key System Features:
High Efficiency DL40/28W/SS Systems
• PROStart Xtreme: For frequent switching, Longest lamp life
• Universal Input Voltage (120-277)
New exclusive
QHE energy saving
electronic DL40/28W/IS
SUPERSAVER® Systems:
• SAME LIGHT,
LESS POWER
• Saves up to 14%
over standard
systems
• Universal Input
Voltage (120-277V)
• QUICKSENSE® end of lamp life sensing
• Auto reset
174
• Available in 0.71 ballast factor
112%
110%
100%
% Relative Light Output
% System Wattage
100% 100%
18%
Energy
Savings
90%
97%
93%
84%
82%
80%
39%
Energy
Savings
70%
61%
60%
43%
Energy
Savings
57%
51%
50%
40%
49%
Energy
Savings
2-F34T12
E.S. Mag. Ballast
2-FO32/700
QTP 2x32 ISN
2-FO30/XP/SS
QTP 2x32 PSX
2-FO28/XP/SS
QTP 2x32 PSX
2-FO25/XP/SS
QTP 2x32 PSX
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 175
MULTIWATT
QUICKSENSE®
New electronic ballasts that offer the versatility to operate multiple
The patented end-of-lamp-life sensing technology that helps
lamp types of various wattages. These multi-watt and multi-lamp
models also can vary the number of lamps operated (i.e. 1 or 2
prevent lamp overheating and established the benchmark for
industry recommendations for T5 and smaller diameter lamps.
lamps), reducing the amount of ballast types required.
PLUS (High Ballast Factor) Systems
Dual Entry CFL
T8 lamps are run at higher lumen levels to allow fewer lamps or
Dual entry, color coded connectors located on
higher light levels.
the side and bottom allow for increased mounting
flexibility with one ballast and also increased ease of installation.
ICETRON® Systems
Unique “Inductively Coupled Electrodeless Fluorescent Lamp
T5HO HELIOS™ Dimming
Electronic ballast with continuous 100-1% dimming range.
Systems” that provide 100,000 hour rated lamp life for use in
high maintenance cost areas.
They can be controlled by a wide variety of 0-10 volt DC control
devices, including daylight sensors, building automation systems
Electronic Metal Halide Systems
and compatible wall box dimming controllers.
QUICKTRONIC® MH features a state of the art electronic design
DALI Digital Dimming
to deliver performance levels unattainable with standard
magnetic based lighting systems. Provides energy savings up to
DALI digital control technology offers full-range continuous
dimming, individual fixture control and feedback. The communications protocol is “DALI”, an acronym for “Digital Addressable
Lighting Interface”. DALI is the worldwide standard for digital
lighting control.
T8 & T5 POWERSENSE® DIMMING
The industry’s first product to
operate from either Power-line
Fluorescent controllers or lowvoltage (0-10 Vdc) controls.
• Efficient - Highest Energy
Efficiency dimming system
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
50% compared to magnetic ballasts. New high wattage systems
coming soon!
LED Power Supplies & DIMMING Modules
OSRAM OPTOTRONIC® power supplies are available in wide
range of input voltages for worldwide use on single-phase AC
power lines. These supplies are available with constant voltage or
constant current outputs.
The OPTOTRONIC OTDIM are dimming modules that can be
used with LED power supply modules.
For Complete power supply and LED module details,
refer to the OSRAM SYLVANIA LED Systems
Specification Guide or www.sylvania.com.
• Versatile - Controls flexibility & universal-voltage
The QUICK 60+®
System Warranty
• Intelligent - Senses faulty
wiring and lamp failure
It’s the simple way to make sure
you’re completely covered.
It starts with the ballast. When you
purchase any QUICKTRONIC
ballast, it’s warranted for a period
of up to 60 months. Then, when
you add SYLVANIA lamps, you
benefit from additional coverage
for those lamps; that’s the PLUS. (For lamp replacements, OSRAM
SYLVANIA will send lamps to your facility – no labor for lamps.)
With our lamps and ballasts, your installation will enjoy the highest
levels of performance. If there is an issue, there’s only one phone
call to make; you won’t get caught in the middle!
PENTRON® HO
New T5 high output fluorescent lamp systems provide almost
twice the lumen output of standard lamps and allow new low
profile fixtures to be designed.
It’s that simple.
For detailed warranty information, call 1-800-LIGHTBULB,
(1-800-544-4828) and request warranty service or visit
www.sylvania.com.
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
175
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 176
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
All data shown is for primary lamp types only. Complete performance data is available in the
SYLVANIA QUICKTRONIC® Electronic Ballast Technology & Specification Guide and at www.sylvania.com
Input
Current
(AMPS)
Lamp
Type
Rated
Lumens
(lm)
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Mean
Lumens1
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® HIGH EFFICIENCY 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS
LOW BALLAST FACTOR
QHE 1X32T8/UNV ISL-SC
49837
49861
49862
Banded Pack
10-Pack
Pallet Pack
120-277
0.21/0.09
0.21/0.09
0.20/0.09
0.19/0.08
0.17/0.08
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.78
0.78
0.78
0.78
0.78
2185
2340
2220
2125
1930
1965
2225
2110
2020
1835
25
25
24
22
20
87
94
93
97
97
120-277
0.41/0.18
0.41/0.18
0.38/0.16
0.35/0.15
0.32/0.14
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.78
0.78
0.78
0.78
0.78
4370
4680
4445
4250
3860
3930
4445
4225
4040
3665
48
48
45
42
37
91
98
99
101
104
120-277
0.61/0.27
0.61/0.27
0.58/0.25
0.53/0.23
0.48/0.21
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.78
0.78
0.78
0.78
0.78
6550
7020
6670
6380
5790
5895
6670
6335
6060
5500
71
71
68
63
55
92
99
98
101
105
120-277
0.80/0.35
0.80/0.35
0.75/0.32
0.71/0.31
0.62/0.27
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
4
4
4
4
4
0.78
0.78
0.78
0.78
0.78
8735
9360
8890
8500
7720
7860
8890
8445
8075
7335
95
95
89
84
74
92
99
100
101
104
QHE 2X32T8/UNV ISL-SC
49838
49863
49864
Banded Pack
10-Pack
Pallet Pack
QHE 3X32T8/UNV ISL-SC
49839
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
49865
49866
Banded Pack
10-Pack
Pallet Pack
QHE 4X32T8/UNV ISL-SC
49840
49867
49868
Banded Pack
10-Pack
Pallet Pack
NORMAL BALLAST FACTOR
QHE 1X32T8/UNV ISN-SC
49968
49851
49852
Banded Pack
10-Pack
Pallet Pack
120-277
0.25/0.11
0.25/0.11
0.22/0.09
0.21/0.09
0.19/0.09
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.88
0.88
0.88
0.88
0.88
2465
2640
2510
2400
2175
2220
2510
2385
2280
2065
28
28
26
25
22
88
94
97
96
99
120-277
0.47/0.20
0.47/0.20
0.44/0.19
0.40/0.18
0.36/0.16
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.88
0.88
0.88
0.88
0.88
4925
5280
5015
4800
4355
4430
5015
4765
4560
4135
55
55
52
48
43
90
96
96
100
101
120-277
0.69/0.30
0.69/0.30
0.66/0.28
0.61/0.26
0.55/0.23
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.88
0.88
0.88
0.88
0.88
7390
7920
7525
7195
6530
6650
7525
7150
6835
6205
83/82
83/82
78/77
72
65/64
89/90
95/97
96/98
100
101/102
120-277
0.91/0.39
0.91/0.39
0.86/0.37
0.80/0.35
0.71/0.30
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
4
4
4
4
4
0.88
0.88
0.88
0.88
0.88
9855
10560
10030
9590
8710
8870
10030
9530
9110
8275
108/107
108/107
102/101
95
85
91/92
98/99
98/99
101
102
QHE 2X32T8/UNV ISN-SC
49969
49853
49854
Banded Pack
10-Pack
Pallet Pack
QHE 3X32T8/UNV ISN-SC
49970
49855
49856
Banded Pack
10-Pack
Pallet Pack
QHE 4X32T8/UNV ISN-SC
49971
49857
49858
Banded Pack
10-Pack
Pallet Pack
Instant Start QHE ISL and ISN models above also operate these lamps: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) & FO40T8
HIGH BALLAST FACTOR
QHE 1X32T8/UNV ISH-SC
49919
49871
49872
Banded Pack
10-Pack
Pallet Pack
120-277
0.32/0.14
0.32/0.14
0.30/0.13
0.27/0.12
0.26/0.12
FO32/700
FO32/XP
FO30SS
FO28SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
1.20
1.20
1.20
1.20
1.20
3360
3600
3420
3270
2970
3025
3420
3250
3105
2820
38
38
36
33
30
88
95
95
99
99
120-277
0.65/0.28
0.65/0.28
0.59/0.25
0.55/0.23
0.50/0.22
FO32/700
FO32/XP
FO30SS
FO28SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
1.20
1.20
1.20
1.20
1.20
6720
7200
6840
6540
5940
6050
6840
6500
6210
5640
74/73
74/73
70/69
65/64
58/57
91/92
97/99
98/99
101/102
102/104
120-277
0.93/0.40
0.93/0.40
0.87/0.38
0.82/0.35
0.72/0.31
FO32/700
FO32/XP
FO30SS
FO28SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
1.18
1.18
1.18
1.18
1.18
9910
10620
10090
9650
8760
8920
10090
9585
9170
8320
111/109
111/109
104/103
98/96
87/86
89/90
96/97
97/98
98/101
101/102
1.15
1.15
1.15
1.15
1.15
12880
13800
13110
12535
11385
11590
13110
12455
11910
10815
144/141
144/141
135/133
127/124
112/111
89/91
96/98
97/99
99/101
102/103
QHE 2X32T8/UNV ISH-SC
49920
49873
49874
Banded Pack
10-Pack
Pallet Pack
QHE 3X32T8/UNV ISH-SC
49921
49875
49876
Banded Pack
10-Pack
Pallet Pack
QHE 4X32T8/UNV ISH
1.21/0.52
FO32/700
2800
4
1.21/0.52
FO32/XP
3000
4
49877
120-277
1.13/0.49
FO30SS
2850
4
49878
1.06/0.46
FO28SS
2725
4
0.94/0.41
FO25/SS
2475
4
Instant Start QHE ISH models above also operate these lamps: FBO32, FBO31, FBO30/SS (30W) & FBO29/SS (29W)
49922
176
Banded Pack
10-Pack
Pallet Pack
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
1: Mean Lumens @ 8000 hours
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 177
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Input
Current
(AMPS)
Lamp
Type
Rated
Lumens
(lm)
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Mean
Lumens1
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® PROFESSIONAL 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS
LOW BALLAST FACTOR
QTP1x32T8/UNV ISL-SC
49832
49741
49742
Banded Pack
10-Pack
Pallet Pack
120-277
0.22/0.10
0.22/0.10
0.22/0.09
0.21/0.08
0.17/0.08
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.78
0.78
0.78
0.78
0.78
2185
2340
2220
2125
1930
1965
2220
2110
2020
1835
28/26
28/26
26/24
25/23
22/20
70/76
84/90
86/93
85/92
88/97
120-277
0.44/0.19
0.44/0.19
0.41/0.18
0.38/0.17
0.34/0.15
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.78
0.78
0.78
0.78
0.78
4370
4680
4445
4250
3860
3930
4445
4220
4040
3665
51
51
48
45
40
86
92
93
94
97
120-277
0.65/0.27
0.65/0.27
0.60/0.26
0.57/0.25
0.50/0.21
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.78
0.78
0.78
0.78
0.78
6550
7020
6670
6380
5790
5895
6670
6335
6060
5500
75
75
71
67
59
87
94
94
95
98
120-277
0.80/0.35
0.80/0.35
0.78/0.34
0.73/0.32
0.63/0.28
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
4
4
4
4
4
0.78
0.78
0.78
0.78
0.78
8735
9360
8890
8500
7720
7860
8890
8445
8075
7335
98
98
92
86
77
89
96
97
99
100
QTP2x32T8/UNV ISL-SC
49834
49743
49744
Banded Pack
10-Pack
Pallet Pack
QTP3x32T8/UNV ISL-SC
49835
49745
49746
Banded Pack
10-Pack
Pallet Pack
QTP4x32T8/UNV ISL-SC
49836
49747
49748
Banded Pack
10-Pack
Pallet Pack
NORMAL BALLAST FACTOR
QTP1x32T8/UNV ISN-SC
49905
49941
49942
Banded Pack
10-Pack
Pallet Pack
120-277
0.26/0.11
0.26/0.11
0.25/0.11
0.23/0.10
0.20/0.09
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.88
0.88
0.88
0.88
0.88
2465
2640
2510
2400
2180
2220
2510
2385
2280
2070
30
30
28
26
23
82
88
90
91
95
120-277
0.50/0.21
0.50/0.21
0.46/0.20
0.43/0.19
0.39/0.16
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.88
0.88
0.88
0.88
0.88
4930
5280
5015
4800
4360
4435
5015
4765
4560
4140
59
59
55
52
46
84
89
91
92
95
120-277
0.75/0.32
0.75/0.32
0.69/0.30
0.65/0.28
0.58/0.25
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.88
0.88
0.88
0.88
0.88
7390
7920
7520
7190
6530
6650
7525
7145
6830
6205
86
86
81
76
67
86
92
93
95
98
120-277
0.95/0.40
0.95/0.40
0.91/0.39
0.85/0.37
0.74/0.31
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
4
4
4
4
4
0.88
0.88
0.88
0.88
0.88
9855
10560
10030
9590
8710
8870
10030
9530
9110
8275
112
112
105
98
88
88
94
96
98
99
QTP2x32T8/UNV ISN-SC
49906
49943
49944
Banded Pack
10-Pack
Pallet Pack
QTP3x32T8/UNV ISN-SC
49907
49945
49946
Banded Pack
10-Pack
Pallet Pack
QTP4x32T8/UNV ISN-SC
49908
49947
49948
Banded Pack
10-Pack
Pallet Pack
Instant Start QTP ISL and ISN models above also operate these lamps: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) & FO40T8
HIGH BALLAST FACTOR
QTP1x32T8/UNV ISH-SC
49829
49841
49842
Banded Pack
10-Pack
Pallet Pack
120-277
0.33/0.15
0.33/0.15
0.31/0.14
0.29/0.13
0.27/0.12
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
1.20
1.20
1.20
1.20
1.20
3360
3600
3420
3270
2970
3025
3420
3250
3105
2820
41
41
39
36
32
82
88
89
91
93
120-277
0.65/0.28
0.65/0.28
0.61/0.26
0.57/0.25
0.51/0.22
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
1.20
1.20
1.20
1.20
1.20
6720
7200
6840
6540
5940
6050
6840
6500
6210
5640
78
78
73
69
61
86
92
93
95
97
1.18
1.18
1.18
1.18
1.18
9910
10620
10090
9650
8760
8920
10090
9585
9170
8320
114/111
114/111
107/104
100/98
89/88
87/89
93/96
94/97
97/98
98/99
QTP2x32T8/UNV ISH-SC
49830
49843
49844
Banded Pack
10-Pack
Pallet Pack
QTP3x32T8/UNV ISH-SC
0.95/0.41
FO32/700
2800
3
0.95/0.41
FO32/XP
3000
3
49845
120-277
0.89/0.39
FO30/SS
2850
3
49846
0.84/0.36
FO28/SS
2725
3
0.75/0.32
FO25/SS
2475
3
Instant Start QTP ISH models above also operate these lamps: FBO32, FBO31, FBO30/SS (30W) & FBO29/SS (29W)
49831
Banded Pack
10-Pack
Pallet Pack
SPECIFICATIONS:
Information is subject to change at anytime without prior notice.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
1: Mean Lumens @ 8000 hours
177
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 178
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Input
Current
(AMPS)
Lamp
Type
Rated
Lumens
(lm)
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Mean
Lumens1
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® HIGH EFFICIENCY SYSTEMS 32 T8 PROStart® PSX UNIVERSAL VOLTAGE SYSTEMS
Xtreme SYSTEMS – LOW BALLAST FACTOR
QTP 1x32T8/UNV PSX-TC
51224
51420
Banded Pack
10-Pack
120-277
0.21/0.09
0.21/0.09
FO32/700
FO32/XPS
2800
3100
1
1
0.71
0.71
1990
2200
1790
2090
25
25
80
88
120-277
0.40/0.17
0.40/0.17
FO32/700
FO32/XPS
2800
3100
2
2
0.71
0.71
3975
4400
3580
4180
47/46
47/46
85/86
94/96
120-277
0.59/0.25
0.59/0.25
FO32/700
FO32/XPS
2800
3100
3
3
0.71
0.71
5965
6600
5370
6270
73/71
73/71
82/84
90/93
120-277
0.78/0.33
0.78/0.33
FO32/700
FO32/XPS
2800
3100
4
4
0.71
0.71
7950
8800
7155
8360
93/91
93/91
85/87
95/96
QTP 2x32T8/UNV PSX-TC
51225
51425
Banded Pack
10-Pack
QTP 3x32T8/UNV PSX-SC
51226
51430
Banded Pack
10-Pack
QTP 4x32T8/UNV PSX-SC
51227
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
51435
Banded Pack
10-Pack
Xtreme SUPERSAVER® SYSTEMS – LOW BALLAST FACTOR
QTP 1x32T8/UNV PSX-TC
51224
51420
51421
Banded Pack
10-Pack
Pallet Pack
120-277
0.21/0.09
0.21/0.09
0.19/0.09
0.18/0.08
FO32/700
FO30/SS
FO28/SS
FO25/SS
2800
2850
2725
2475
1
1
1
1
0.71
0.71
0.71
0.71
1990
2020
1935
1760
1790
1920
1840
1670
25
24
22
20
80
84
88
88
120-277
0.37/0.16
0.37/0.16
0.35/0.15
0.32/0.14
FO32/700
FO30/SS
FO28/SS
FO25/SS
2800
2850
2725
2475
2
2
2
2
0.71
0.71
0.71
0.71
3975
4045
3870
3515
3580
3840
3675
3340
47/46
44/43
41/40
37/36
85/86
92/94
94/97
95/98
120-277
0.58/0.24
0.58/0.24
0.55/0.23
0.48/0.31
FO32/700
FO30/SS
FO28/SS
FO25/SS
2800
2850
2725
2475
3
3
3
3
0.71
0.71
0.71
0.71
5965
6070
5805
5270
5370
5765
5515
5010
73/71
69/67
64/62
57/56
82/84
88/91
91/94
93/94
120-277
0.74/0.31
0.74/0.31
0.70/0.30
0.63/0.27
FO32/700
FO30/SS
FO28/SS
FO25/SS
2800
2850
2725
2475
4
4
4
4
0.71
0.71
0.71
0.71
7950
8090
7740
7030
7155
7685
7350
6680
93/91
88/86
82/80
75/74
85/87
92/94
94/97
94/95
QTP 2x32T8/UNV PSX-TC
51225
51425
51426
Banded Pack
10-Pack
Pallet Pack
QTP 3x32T8/UNV PSX-SC
51226
51430
51431
Banded Pack
10-Pack
Pallet Pack
QTP 4x32T8/UNV PSX-SC
51227
51435
51436
Banded Pack
10-Pack
Pallet Pack
PROStart QTP PSX models above also operate these lamps: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS(30W) & FBO29/SS(29W)
QUICKTRONIC PROFESSIONAL 32 T8 PROStart PSN UNIVERSAL VOLTAGE SYSTEMS
NORMAL BALLAST FACTOR
QTP 1x32T8/UNV PSN-TC
51399
51400
51401
Banded Pack
10-Pack
Pallet Pack
120-277
0.26/0.11
0.26/0.11
0.24/0.10
0.23/0.09
0.20/0.09
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.88
0.88
0.88
0.88
0.88
2465
2640
2510
2400
2175
2220
2510
2385
2280
2065
31/30
31/30
29/28
27/26
24/23
79/82
85/88
87/90
89/92
91/95
120-277
0.50/0.21
0.50/0.21
0.47/0.20
0.45/0.19
0.39/0.17
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.88
0.88
0.88
0.88
0.88
4930
5280
5015
4800
4355
4437
5015
4765
4560
4135
59/56
59/56
55/53
52/49
46/44
84/88
89/94
91/95
92/98
95/99
120-277
0.74/0.31
0.74/0.31
0.70/0.29
0.65/0.27
0.58/0.25
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.88
0.88
0.88
0.88
0.88
7390
7920
7525
7195
6530
6650
7525
7150
6835
6205
88/85
88/85
83/80
77/75
69/68
84/87
90/93
91/94
93/96
95/96
120-277
0.99/0.41
0.99/0.41
0.93/0.39
0.88/0.36
0.77/0.32
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
4
4
4
4
4
0.88
0.88
0.88
0.88
0.88
9855
10,560
10,030
9590
8710
8870
10,030
9530
9110
8275
118/113
118/113
111/106
104/99
92/90
83/87
90/94
90/95
92/97
95/97
QTP 2x32T8/UNV PSN-TC
51402
51405
51406
Banded Pack
10-Pack
Pallet Pack
QTP 3x32T8/UNV PSN-SC
51403
51410
51411
Banded Pack
10-Pack
Pallet Pack
QTP 4x32T8/UNV PSN-SC
51404
51415
51416
Banded Pack
10-Pack
Pallet Pack
PROStart QTP PSN models above also operate these lamps: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W) & FBO29/SS (29W)
PROStart
A programmed rapid starting method for fluorescent lamps
that achieves up to 100,000 switching cycles which is ideal for
use on occupancy sensors.
• Exclusive lamp warranty for occupancy sensor applications.
178
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
1: Mean Lumens @ 8000 hours
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 179
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Input
Current
(AMPS)
Lamp
Type
Rated
Ballast
Lumens No. of Factor
(lm)
Lamps (BF)
System
Lumens
Mean
Lumens
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® HIGH EFFICIENCY 32 T8 PROStart® UNIVERSAL VOLTAGE SYSTEMS
HIGH BALLAST FACTOR (90°C Case Temperature – Parallel Operation)1
49450 =
49459
49453 =
49460
49455 =
49470
QHE2x32T8/UNV-PSH-HT
Banded Pack
Pallet Pack
120-277
0.63/0.27
0.63/0.27
0.60/0.25
0.55/0.24
0.50/0.21
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2830
2725
2475
2
2
2
2
2
1.15
1.15
1.15
1.15
1.15
6440
6900
6510
6270
5695
5795
6555
6185
5955
5410
75/74
75/74
70/69
66/65
59/58
86/87
92/93
93/94
95/96
96/98
120-277
0.94/0.40
0.94/0.40
0.88/0.38
0.82/0.35
0.73/0.31
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2830
2725
2475
3
3
3
3
3
1.15
1.15
1.15
1.15
1.15
9660
10,350
9765
9400
8540
8695
9830
9275
8930
8110
110/109
110/109
103/102
96/95
86/85
88/89
94/95
95/96
98/99
99/100
120-277
1.24/0.53
1.24/0.53
1.16/0.50
1.09/0.46
0.97/0.41
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2830
2725
2475
4
4
4
4
4
1.15
1.15
1.15
1.15
1.15
12,880
13,800
13,020
12,535
11,385
11,590
13,110
13,370
11,910
10,815
146/144
146/144
137/135
128/126
114/113
88/89
95/96
95/96
98/99
100/101
QHE3x32T8/UNV-PSH-HT
Banded Pack
Pallet Pack
QHE4x32T8/UNV-PSH-HT
Banded Pack
Pallet Pack
PROStart® QHE PSH models above also operate these lamps: FBO32, FBO31, FBO30/SS (30W) & FBO29/SS (29W)
QUICKTRONIC HIGH EFFICIENCY 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS
NORMAL BALLAST FACTOR - UL Type CC - Lamp Striation Control/LSC1
49381
49382
49383
49384
49385
49386
49387
49388
QHE1x32T8/UNV-ISN-SC-1
Banded Pack
Pallet Pack
120-277
0.25/0.11
0.25/0.11
0.23/0.09
0.21/0.09
0.20/0.90
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.87
0.87
0.87
0.87
0.87
2435
2610
2480
2370
2155
2190
2480
2355
2250
2045
28
28
27/26
25/24
23/22
87
93
92/95
95/99
94/98
120-277
0.47/0.20
0.47/0.20
0.44/0.19
0.40/0.18
0.37/0.16
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.87
0.87
0.87
0.87
0.87
4870
5220
4960
4740
4305
4385
4960
4710
4500
4090
55
55
52
48/47
44/43
89
95
95
99/101
98/100
120-277
0.68/0.30
0.68/0.30
0.65/0.28
0.61/0.26
0.55/0.23
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.87
0.87
0.87
0.87
0.87
7305
7830
7440
7110
6460
6940
7440
7070
6755
6135
82/81
82/81
77/76
72/71
65/64
89/90
96/97
97/98
99/100
99/101
120-277
0.92/0.39
0.92/0.39
0.86/0.37
0.80/0.35
0.74/0.31
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
4
4
4
4
4
0.87
0.87
0.87
0.87
0.87
9745
10,440
9920
9485
8615
9255
9920
9425
9010
8185
109/107
109/107
102
95/94
87/86
89/91
96/98
97
100/101
99/100
QHE2x32T8/UNV-ISN-SC-1
Banded Pack
Pallet Pack
QHE3x32T8/UNV-ISN-SC-1
Banded Pack
Pallet Pack
QHE4x32T8/UNV-ISN-SC-1
Banded Pack
Pallet Pack
Instant Start QHE ISN models above also operate these lamps: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) & FO40T8
QUICKTRONIC HIGH EFFICIENCY 59 T8 (8 foot) INSTANT START UNIVERSAL VOLTAGE SYSTEMS
LOW BALLAST FACTOR2
50239*
49869
49870
QHE2x59T8/UNV-ISL-SC
10-Pack
Pallet Pack
120-277
0.80/0.34
0.80/0.34
0.74/0.32
FO96T8/700 (59W)
FO96T8/XP (59W)
FO96T8/XP/SS (55W)
5700
6100
5700
2
2
2
0.77
0.77
0.77
8780
9380
8780
7900
8910
8340
95/94
95/94
89/88
92/93
99/100
99/100
2
2
2
0.88
0.88
0.88
10,030
10,735
10,030
9025
10,200
9530
109/107
109/107
102/100
92/94
98/100
99/100
2
2
2
1.15
1.15
1.15
13,110
14,030
13,110
11,800
13,330
12,455
144/141
144/141
134/131
91/93
97/100
98/100
9027
10,200
9530
112/110
112/110
104/102
90/91
96/98
96/98
J
J
J
J
NORMAL BALLAST FACTOR2
50237*
49859
49860
QHE2x59T8/UNV-ISN-SC
10-Pack
Pallet Pack
120-277
0.92/0.40
0.92/0.40
0.84/0.36
FO96T8/700 (59W)
FO96T8/XP (59W)
FO96T8/XP/SS (55W)
5700
6100
5700
HIGH BALLAST FACTOR2
50238*
49879
49880
QHE2x59T8/UNV-ISH
10-Pack
Pallet Pack
120-277
1.20/0.52
1.20/0.52
1.08/0.47
FO96T8/700 (59W)
FO96T8/XP (59W)
FO96T8/XP/SS (55W)
5700
6100
5700
QHE2x59T8-ISL-SC and QHE2x59T8-ISN-SC models also operate these lamps: FO72T8 & FO48T8
QUICKTRONIC PROFESSIONAL 59 T8 (8 foot) INSTANT START UNIVERSAL VOLTAGE SYSTEMS
NORMAL BALLAST FACTOR2
49590*
49598
49599
QTP 2x59T8/UNV ISN-SC
10-Pack
Pallet Pack
120-277
0.93/0.40
0.93/0.40
FO96T8/700 (59W)
FO96T8/XP (59W)
FO96T8/XP/SS (55W)
5700
6100
5700
2
2
2
0.88
0.88
0.88
10,030
10,735
10,030
Instant Start QTP ISN models above also operate these lamps: FO72T8 & FO48T8
QUICKTRONIC HIGH EFFICIENCY 86 T8/HO (8 foot) PROStart UNIVERSAL VOLTAGE SYSTEMS
NORMAL BALLAST FACTOR (90°C Case Temperature – Parallel Operation)2
50304 =* QHE 2x86T8HO/UNV-PSN-HT-SCL
50305
Pallet Pack
120-277
J
J
FO96T8/700/HO
FO96T8/800/HO
8000
8200
2
2
J
J
J
J
J
J
PROStart® QHE 2x86T8HO also operates these lamps: F72, F60T8HO & F48T8HO
1: Mean Lumens @ 8000 hours, 2: Mean Lumens for T8 (8 foot) @ 6000 hours , *10 Piece Banded Pack Item Number, ❏ Contact OSRAM SYLVANIA for product information.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
❂ New Product. Contact OSRAM SYLVANIA for product availability.
179
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 180
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Rated
Voltage
(VAC)
Input
Current
(AMPS)
Lamp
Type
Rated
Lumens
(lm)
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Mean
Lumens1
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® HIGH EFFICIENCY 32 T8 INSTANT START 347 VOLT SYSTEMS – CANADA
LOW BALLAST FACTOR
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
49471
QHE 1X32T8/347 ISL-SC
347
0.08
0.08
0.07
0.07
0.06
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.78
0.78
0.78
0.78
0.78
2185
2340
2220
2125
1930
1965
2220
2110
2020
1835
25
25
24
22
20
87
94
93
97
97
49473
QHE 2X32T8/347 ISL-SC
347
0.14
0.14
0.13
0.12
0.12
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.78
0.78
0.78
0.78
0.78
4370
4680
4445
4250
3860
3930
4445
4220
4040
3665
48
48
46
43
38
91
98
97
99
102
49475
QHE 3X32T8/347 ISL-SC
347
0.21
0.21
0.20
0.18
0.17
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.78
0.78
0.78
0.78
0.78
6550
7020
6670
6380
5790
5895
6670
6340
6060
5500
71
71
67
62
55
92
99
100
103
105
49477
QHE 4X32T8/347 ISL-SC
347
0.28
0.28
0.26
0.25
0.23
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
4
4
4
4
4
0.78
0.78
0.78
0.78
0.78
8735
9360
8890
8500
7720
7860
8890
8445
8075
7335
96
96
90
84
74
91
98
99
101
104
49461
QHE 1X32T8/347 ISN-SC
347
0.08
0.08
0.08
0.07
0.07
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
1
1
1
1
1
0.88
0.88
0.88
0.88
0.88
2465
2640
2510
2400
2175
2220
2510
2385
2280
2065
28
28
27
25
22
88
94
93
96
99
49463
QHE 2X32T8/347 ISN-SC
347
0.16
0.16
0.15
0.14
0.13
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
2
2
2
2
2
0.88
0.88
0.88
0.88
0.88
4925
5280
5015
4800
4355
4430
5015
4765
4560
4135
55
55
52
48
43
90
96
96
100
101
49465
QHE 3X32T8/347 ISN-SC
347
0.25
0.25
0.24
0.22
0.20
FO32/700
FO32/XP
FO30/SS
FO28/SS
FO25/SS
2800
3000
2850
2725
2475
3
3
3
3
3
0.88
0.88
0.88
0.88
0.88
7390
7920
7525
7195
6530
6650
7525
7150
6835
6205
83
83
78
74
66
89
95
96
97
99
49467
QHE 4X32T8/347 ISN-SC
347
0.33
FO32/700
2800
4
0.88
9855
8870
0.33
FO32/XP
3000
4
0.88
10,560
10,030
0.31
FO30/SS
2850
4
0.88
10,030
9530
0.29
FO28/SS
2725
4
0.88
9590
9110
0.26
FO25/SS
2475
4
0.88
8710
8275
Instant Start QHE ISL and ISN models above also operate these lamps: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) & FO40T8
109
109
103
97
87
90
97
97
99
100
49241
QT2X32T8/347 ISL-SC
347
0.15
FO32/XP
3000
2
0.77
4620
4390
51
91
49939
QT4X32T8/347 ISL-SC
347
0.28
FO32/XP
3000
4
0.77
9240
8775
98
94
NORMAL BALLAST FACTOR
QUICKTRONIC 32 T8 INSTANT START 347 VOLT SYSTEMS – CANADA
LOW BALLAST FACTOR
QUICKTRONIC PROFESSIONAL 32 T8 INSTANT START 347 VOLT SYSTEMS – CANADA
NORMAL BALLAST FACTOR
49711
QTP1X32T8/347 ISN-SC
347
0.089
FO32/XP
3000
1
0.88
2700
2565
31
90
49713
QTP2X32T8/347 ISN-SC
347
0.165
FO32/XP
3000
2
0.88
5280
5015
59
89
0.90
8100
7695
87
93
QUICKTRONIC 32 T8 INSTANT START 347 VOLT SYSTEMS – CANADA
NORMAL BALLAST FACTOR
49993
QT3X32T8/347 ISN-SC
347
0.25
FO32/XP
3000
3
49994
QT4X32T8/347 ISN-SC
347
0.34
FO32/XP
3000
4
0.90
10,800
10,260
112
Instant Start QTP ISN and QT ISL and ISN models above also operate these lamps: FBO32, FBO31, FO25, FO40, FBO24, FO17, FBO16, FO30/SS(30W), FBO30/SS, FBO29/SS,
FO28/SS(28W) & FO25/SS(25W)
96
HIGH BALLAST FACTOR
49927
QT2X32T8/347 ISH-SC
347
0.23
FO32/XP
3000
2
1.2
Instant Start QT ISH model above also operates these lamps: FO30/SS, FO28/SS, FO25/SS, FBO32, FBO31, FBO30/SS & FBO29/SS
7200
6840
78
92
10,735
10,200
110
98
QUICKTRONIC 59 T8 (8 foot) INSTANT START 347 VOLT SYSTEMS – CANADA
NORMAL BALLAST FACTOR
49217
QT2X59/347 IS
347
0.33
Instant Start QT IS model above also operates the FO96/SS lamp (55W)
FO96T8 XP(59W)
6100
2
0.88
1: Mean Lumens @ 8000 hours
180
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
❂ New Product. Contact OSRAM SYLVANIA for product availability.
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 181
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Input
Current
(AMPS)
Lamp
Type
Rated
Lumens
(lm)
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® PROFESSIONAL T5HO PROStart® PSN UNIVERSAL VOLTAGE SYSTEMS
NORMAL BALLAST FACTOR 3
49111
QTP 2x39-24T5HO/UNV PSN NL
120-277
0.47/0.20
FP24T5HO
2000
2
1
1.00
1.00
4000
2000
55/54
29
73/74
70
49111
QTP 2x39-24T5HO/UNV PSN NL
120-277
0.76/0.32
FP39T5HO
3500
2
1
1.00
1.00
7000
3500
85/83
42
82/84
83
49131
QTP 2x54T5HO/UNV PSN NL
120-277
1.00/0.43
FP54T5HO
5000
2
1
1.00
1.00
10000
5000
121/118
61
83/85
82
49151
QTP 1x80T5HO/UNV PSN NL
120-277
0.74/0.32
FP80T5HO
FT80T5DL
6000
7000
1
1
1.00
1.00
7000
6000
90
90
78
67
(49110)
(49110)
(49130)
(49150)
(Item Number) = Item Number/NAED in parentheses are models with leads/wires. See Ballast Technology & Specification Guide for additional lamp types and full specifications.
QUICKTRONIC PROFESSIONAL T5 PROStart PSN UNIVERSAL VOLTAGE SYSTEMS
NORMAL BALLAST FACTOR 3
49181
(49180)
QTP 2x28T5/UNV PSN NL
120-277
0.55/0.23
FP28T5
2900
2
1
1.00
1.00
5800
2900
65/63
32
89/92
90
PROStart® QTP PSN models above also operate these lamps: FP14, FP21 & FP35
(Item Number) = Item Number/NAED in parentheses are models with leads/wires.
QUICKTRONIC PROFESSIONAL T5HO PROStart UNIVERSAL VOLTAGE HIGH AMBIENT TEMP. SYSTEMS
FIXED OUTPUT 3
49136
(49135)
QTP 2x54T5HO/UNV PSN HT NL
120-277
1.00/0.43
FP54T5HO
5000
2
1
1.00
1.00
10000
5000
121/118
61
83/85
82
4
3
2
1
1.00
1.00
1.00
1.00
20000
15000
10000
5000
241/236
182/178
121/118
61
83/85
83/85
83/85
82
10000
5000
121/120
61
83
82
SWITCHABLE MODEL3
49161
(49160)
QTP 4x54T5HO/UNV PSN HTW NL
120-277
2.00/0.85
FP54T5HO
5000
PROStart® QTP PSN models above also operate these lamps: FT55DL, FPC55, L58
(Item Number) = Item Number/NAED in parentheses are models with leads/wires.
QUICKTRONIC PROFESSIONAL T5HO PROStart 347- 480V HIGH AMBIENT TEMP. SYSTEMS
NORMAL BALLAST FACTOR 3
49146
(49145)
QTP 2x54T5HO/347-480 PSN HT NL
347-480
0.35/0.25
FP54T5HO
5000
2
1
1.00
1.00
PROStart® QTP PSN models above also operate these lamps: FT55DL, FPC55, L58
(Item Number) = Item Number/NAED in parentheses are models with leads/wires.
QUICKTRONIC HIGH EFFICIENCY INSTANT START DL40 UNIVERSAL VOLTAGE SYSTEMS4
49428
QHE 1x40DL/UNV ISN-SC
120-277
0.30/0.13
0.27/0.12
FT40T5
FT40DL/28W/SS/IS
3150
2800
1
1
0.90
1.07
2835
2995
35
32
81
94
49429
QHE 2x40DL/UNV ISN-SC
120-277
0.56/0.26
0.54/0.24
FT40T5
FT40DL/28W/SS/IS
3150
2800
2
2
0.90
1.07
5670
5990
68/67
64/63
83/84
94/95
49430
QHE 3x40DL/UNV ISN-SC
120-277
0.84/0.36
0.79/0.35
FT40T5
FT40DL/28W/SS/IS
3150
2800
3
3
0.90
1.07
8505
8990
100/99
95/94
85/86
95/96
4
Ballast factor based upon 225mA nominal lamp current for FT40DL lamp and 190mA nominal lamp current for FT40DL/28W/SS/IS lamp.
QUICKTRONIC PROFESSIONAL PROStart DL40
NORMAL BALLAST FACTOR
50320
QTP 1x40TT5/120 PSN-F
120
0.32
FT40T5
3150
1
0.88
2770
38
73
50330
QTP 1x40TT5/277 PSN-F
277
0.13
FT40T5
3150
1
0.88
2770
37
75
50340
QTP 2x40TT5/120 PSN-F
120
0.63
FT40T5
3150
2
0.88
5545
76
73
50350
QTP 2x40TT5/277 PSN-F
277
0.27
FT40T5
3150
2
0.88
5545
73
76
50360
QTP 3x40TT5/120 PSN-B
120
0.92
FT40T5
3150
3
0.88
8315
110
76
50370
QTP 3x40TT5/277 PSN-B
277
0.39
FT40T5
3150
3
0.88
8315
108
77
Formerly: M1-PN-TT5/40-F-120
Formerly: M1-PN-TT5/40-F-277
Formerly: M2-PN-TT5/40-F-120
Formerly: M2-PN-TT5/40-F-277
Formerly: M3-PN-TT5/40-B-120
Formerly: M3-PN-TT5/40-B-277
3: Rated lamp lumens and performance data based on PENTRON® HO lamps. Rated lumens at 35°C lamp ambient temperature
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
❂ New Product. Contact OSRAM SYLVANIA for product availability.
181
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 182
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Input
Current
(AMPS)
Lamp
Type
Rated
Lumens
(lm)
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® PROFESSIONAL PROStart® COMPACT FLUORESCENT - UNIVERSAL VOLTAGE DUAL ENTRY5,6
NORMAL BALLAST FACTOR
51818 =
QTP 1/2x13CF/UNV
51823 =
QTP 1/2x18CF/UNV
51833 =
QTP 2x26CF/UNV
51850 =
51851 =
51852 =
51898
QTP 1/2x18CF/UNV-KIT L
QTP 2x26CF/UNV-KIT L
120-277
0.25/0.11
13W DD/E,T/E
13W DD/E,T/E
900
900
1
2
1.00
1.00
900
1800
16
29
56
62
120-277
0.32/0.14
18W DD/E,T/E
18W DD/E,T/E
1200
1200
1
2
1.00
1.00
1200
2400
20
38
60
63
26W DD/E,T/E
26W DD/E,T/E
32W DT/E
42W DT/E
1800
1800
2400
3200
1
2
1
1
1.00
1.00
0.98
1.00
1800
3600
2350
3200
28
54
35
45
64
67
67
71
1800
2400
3200
4300
5200
2
2
2
1
1
1.02
0.96
0.95
1.00
0.92
3670
4600
6080
4300
4780
54
69
94
62
71
68
67
65
69
67
120-277
QTP 2x26CF/UNV PEM
0.50/0.22
26W DT/E
32W DT/E
51853 = QTP 2x26/32/42CF/UNV M-KIT L
120-277
0.90/0.40
42W DT/E
51863
QTP 2x26/32/42CF/UNV M PEM
0.53/0.23
57W DT/E
0.57/0.25
70W DT/E
Also operates: see Ballast Technology & Specification Guide for additional lamp types.
51843
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
QTP 1/2x13CF/UNV-KIT L
QTP 2x26/32/42CF/UNV M
NORMAL BALLAST FACTOR 51718
51748
QTP 1/2x13CF/UNV BS
QTP 1/2x13CF/UNV TS
120-277
51723
51753
QTP 1/2x18CF/UNV BS
QTP 1/2x18CF/UNV TS
120-277
51733
51763
QTP 2x26CF/UNV BS
QTP 2x26CF/UNV TS
120-277
51738
51798
51768
QTP 1/2xCF/UNV BM
QTP 1/2xCF/UNV PM
QTP 1/2xCF/UNV TM
120-277
51743
51803
51773
QTP 2x26/32/42CF/UNV BM
QTP 2x26/32/42CF/UNV PM
QTP 2x26/32/42CF/UNV TM
Also operates one 57W or 70W
CFL lamps
120-277
LCF Kits include a ballast, screws, wire, mounting bracket, an instruction sheet and a wire removal tool.
QTP CF models above replace shaded item numbers below
0.25/0.11
13W DD/E,T/E
13W DD/E,T/E
900
900
1
2
1.00
1.00
900
1800
16
29
56
62
0.32/0.14
18W DD/E,T/E
18W DD/E,T/E
1200
1200
1
2
1.00
1.00
1200
2400
20
38
60
63
26W DD/E,T/E
26W DD/E,T/E
32W DT/E
42W DT/E
1800
1800
2400
3200
1
2
1
1
1.00
1.00
0.98
1.00
1800
3600
2350
3200
28
54
35
45
64
67
67
71
26W DD/E,T/E
26W DD/E,T/E
32W DT/E
42W DT/E
1800
1800
2400
3200
1
2
1
1
1.02
1.02
0.97
1.00
1830
3670
2330
3200
28
57
36
46
65
64
65
70
26W DT/E
32W DT/E
42W DT/E
57W DT/E
70W DT/E
1800
2400
3200
4300
5200
2
2
2
1
1
1.02
0.96
0.95
1.00
0.92
3670
4600
6080
4300
4780
54
69
94
62
71
68
67
65
69
67
0.50/0.22
0.57/0.25
0.90/0.40
0.53/0.23
0.57/0.25
QUICKTRONIC HIGH EFFICIENCY POWERSENSE® 32 T8 DIMMING SYSTEMS - A list of controllers is available from OSRAM SYLVANIA
Power-line control (2-wire) or 0-10Vdc control (4-wire) - 100-5% Dimming Range - <10% THD
50705
QTP 1x32T8/UNV DIM-TC
120-277
0.27/0.12
FO32XP
3000
1
0.88
0.05
2640
150
30
8
88
50707
QTP 2x32T8/UNV DIM-TC
120-277
0.54/0.24
FO32XP
3000
2
0.88
0.05
5280
300
60/58
15
88/91
50714
QTP 3x32T8/UNV DIM-TCL
120-277
0.73/0.30
FO32XP
3000
3
0.88
0.05
7920
450
87/84
20
91/94
50716
QTP 4x32T8/UNV DIM-TCL
120-277
0.96/0.40
FO32XP
3000
4
114/110
27
92/96
0.88
10560
0.05
600
POWERSENSE™ QTP models above also operate these lamps: FO25, FO17 & FBO32. POWERSENSE T8 replaces former Helios T8 dimming products.
QUICKTRONIC HIGH EFFICIENCY HELIOS™ 32 T8 DIMMING SYSTEMS - A list of controllers is available from OSRAM SYLVANIA
High Ballast Factor - “PLUS” High Light Output System - For 277V, 0-10Vdc Control Applications Only
50718 =
QTP 4x32T8/277 DIM PLUS-TCL
277
0.53
FO32XP
3000
4
1.20
0.05
14400
600
145
28
99
QUICKTRONIC HIGH EFFICIENCY POWERSENSE 28 T5 DIMMING SYSTEMS - A list of controllers is available from OSRAM SYLVANIA
Power-line control (2-wire) or 0-10Vdc control (4-wire) - 100-1% Dimming Range - <10% THD
50726 =
QTP 2x28T5/UNV DIM-TCL
120-277
0.53/0.23
FP28
2900
2
1.00
0.01
5800
58
63/62
10
92/94
POWERSENSE™ QTP model above also operate these lamps: FP35, FP21 & FP14
QUICKTRONIC PROFESSIONAL HELIOS 54 T5 HO DIMMING SYSTEMS3 - A list of controllers is available from OSRAM SYLVANIA
(0-10Vdc control) - 100-1% Dimming Range - <10% THD
49671
QT1x54/120PHO-DIM
120
0.54
FP54T5HO
5000
1
1.00
0.01
5000
50
62
8
81
49672
QT1x54/277PHO-DIM
277
0.23
FP54T5HO
5000
1
1.00
0.01
5000
50
61
8
82
49673
QT2x54/120PHO-DIM
120
1.07
FP54T5HO
5000
2
1.00
0.01
10000
100
120
18
83
49674
QT2x54/277PHO-DIM
277
0.45
FP54T5HO
5000
2
1.00
0.01
10000
100
117
18
85
HELIOS QT models above also operate these lamps: FT55DL & FPC55
3: Rated lamp lumens and performance data based on PENTRON® HO lamps. Rated lumens at 35°C lamp ambient temperature,
182
5: Rated lamp lumens and performance data based on DULUX T/E series 4 pin lamps. 6: Data is for all models within the brackets.
OSRAM SYLVANIA National Customer Service and Sales Center
The maximum input current is shown for maximum input power. ❂ New Product. Contact OSRAM SYLVANIA for product availability.
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 183
Electronic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Input
Current
(AMPS)
Lamp
Type
Rated
Lumens
(lm)
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® PROFESSIONAL DALI DIMMING SYSTEMS - 100-1% Dimming Range - <10% THD - For a list of DALI controllers, contact OSRAM SYLVANIA
T8
51350
QTP 1x32T8/UNV DALI
120-277
0.31/0.13
FO32XP
3000
1
1.00
0.01
3000
30
36
6
83
51352
QTP 2x32T8/UNV DALI
120-277
0.61/0.26
FO32XP
3000
2
1.00
0.01
6000
60
72/70
12
83/86
DALI QTP models above also operate these lamps: FBO32
T5HO
51364
QTP 1x54T5HO/UNV DALI
120-277
0.52/0.22
FP54HO
5000
1
1.00
0.01
5000
50
62/61
9
81/82
51366
QTP 2x54T5HO/UNV DALI
120-277
1.05/0.44
FP54HO
5000
2
1.00
0.01
10,000
100
122/119
18
82/84
T5
51356
QTP 1x28T5/UNV DALI
120-277
0.27/0.11
FP28
2900
1
1.00
0.01
2900
29
32
6
91
51358
QTP 2x28T5/UNV DALI
120-277
0.55/0.23
FP28
2900
2
1.00
0.01
5800
58
64/62
12
91/94
51357
QTP 1x14T5/UNV DALI
120-277
0.15/0.07
FP14
1350
1
1.00
0.01
1350
14
18
75
51359
QTP 2x14T5/UNV DALI
120-277
0.29/0.13
FP14
1350
2
1.00
0.01
2700
27
34/33
79/82
51360
QTP 1x35T5/UNV DALI
120-277
0.34/0.14
FP35
3650
1
1.00
0.01
3650
37
40/39
91/94
51361
QTP 2x35T5/UNV DALI
120-277
0.67/0.28
FP35
3650
2
1.00
0.01
7300
73
79/76
92/96
QUICKTRONIC PROFESSIONAL DALI COMPACT FLUORESCENT DIMMING SYSTEMS -
For a list of DALI controllers, contact OSRAM SYLVANIA
T4 and TT5 DALI - 100-3% Dimming Range - <10% THD
51370
QTP 1x18CF/UNV DALI
120-277
0.18/0.08
18W
DD/E, T/E
1200
1
1.00
0.03
1200
35
20
60
51372
QTP 2x18CF/UNV DALI
120-277
0.33/0.14
18W
DD/E, T/E
1200
2
1.00
0.03
2400
70
39/38
61/63
51375
QTP 1x26CF/UNV DALI
120-277
0.24/0.10
26W
DD/E, T/E
1800
1
1.00
0.03
1800
55
28
64
51377
QTP 2x26CF/UNV DALI
120-277
0.49/0.22
26W
DD/E, T/E
1800
2
1.00
0.03
3600
110
55/54
65/67
51380
QTP 1x32CF/UNV DALI
120-277
0.34/0.15
32W DT/E
2400
1
1.00
0.03
2400
70
38
63
51382
QTP 2x32CF/UNV DALI
120-277
0.60/0.26
32W DT/E
2400
2
1.00
0.03
4800
140
71/70
68/69
51384
QTP 1x42CF/UNV DALI
120-277
0.43/0.19
42W DT/E
3200
1
1.00
0.03
3200
95
49
65
51386
QTP 2x42CF/UNV DALI
120-277
0.82/0.36
42W DT/E
3200
2
1.00
0.03
6400
190
92/91
69/70
51390
QTP 1x40TT5/UNV DALI
120-277
0.41/0.17
40W DL
3150
1
1.00
0.03
3150
95
45/44
70/72
51392
QTP 2x40TT5/UNV DALI
120-277
0.83/0.37
40W DL
3150
2
1.00
0.03
6300
190
97/94
65/67
QUICKTRONIC 96IS & 96HO
F96T12 Instant Start - Normal Ballast Factor- <20%THD
49881
QT 2x96/120 IS
120
1.12
F96SS
F96
5300
6420
2
2
0.85
0.85
9010
10910
107
132
84
83
49882
QT 2x96/277 IS
277
0.49
F96SS
F96
5300
6420
2
2
0.85
0.85
9010
10910
107
132
84
83
QT IS models above also operate these lamps: F84T12, F72T12 & F60T12
F96T12 High Output- Normal Ballast Factor- <20%THD
49883
QT 2x96/120 HO
120
1.74
F96HOSS
F96HO
8000
9050
2
2
0.89
0.89
14240
16109
170
205
84
79
49884
QT 2x96/277 HO
277
0.76
F96HOSS
F96HO
8000
9050
2
2
0.85
0.85
13600
15385
170
205
80
75
QT HO models above also operate these lamps: F84T12/HO, F72T12/HO, F60T12/HO, & F48T12/HO
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
❂ New Product. Contact OSRAM SYLVANIA for product availability.
183
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 184
Electronic Fluorescent / Metal Halide Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Input
Current
(AMPS)
Rated
Lumens
(lm)
Lamp
Type
No. of
Lamps
Ballast
Factor
(BF)
System
Lumens
Input
Wattage
(W)
System
Efficacy
(lm/W)
QUICKTRONIC® PROFESSIONAL 40 T12 RAPID START
NORMAL BALLAST FACTOR - <10%THD, (3 lamp <20%THD)
50684
QTP 1x40T12/120 RSN-SC
120
0.30
F40T12/D41
3200
1
0.85
2720
35
78
50685
QTP 1x40T12/277 RSN-SC
277
0.13
F40T12/D41
3200
1
0.85
2720
35
78
50686
QTP 2x40T12/120 RSN-SC
120
0.62
F40T12/D41
3200
2
0.85
5440
71
77
50687
QTP 2x40T12/277 RSN-SC
277
0.24
F40T12/D41
3200
2
0.85
5440
71
77
50688
QTP 3x40T12/120 RSN
120
0.91
F40T12/D41
3200
3
0.87
8352
107
78
50689
QTP 3x40T12/277 RSN
277
0.39
F40T12/D41
3200
3
0.87
8352
107
78
QTP T12/RS models above also operate these lamps: F30T12 & F25T12
QUICKTRONIC ICE
ICETRON® Universal Voltage - <15% THD E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
Contact OSRAM SYLVANIA for ICETRON® lamp information
49753
49756
QT 1x100 ICE/UNV-T
QT 1x100 ICE/UNV-W
120-277
0.88/0.37
0.66/0.29
ICE100
ICE70
8000
6200
1
1
1.00
1.05
8000
6500
106/103
79/77
75/77
82/84
49772
49773
QT 1x150 ICE/UNV-T
QT 1x150 ICE/UNV-W
120-277
1.34/0.58
1.28/0.54
ICE150
ICE100
12000
8000
1
1
1.00
1.38
12000
11000
161/156
154/149
74/76
71/73
QUICKTRONIC® FM – DEDICATED VOLTAGE (120V)
Electronic T2 Fluorescent Subminiature Systems
49735
QT1x6-8FM/120
120
120
0.11
0.14
FM 6/H
FM 8/H
330
540
1
1
1.00
1.00
330
540
8
10
41
54
49736
QT1x11-13FM/120
120
120
0.18
0.22
FM 11/H
FM 13/H
750
930
1
1
1.00
1.00
750
930
13
16
58
58
QUICKTRONIC PROFESSIONAL MH
Electronic Metal Halide - Universal Voltage
51908
51909
QTP1x20MH/UNV-F
QTP1x20MH/UNV-J
120-277
0.21/0.085
20W T4.5
1700
1
1.0
1700
23
74
51968 QTP2X20MH UNV F
51969 QTP2X20MH UNV J
120-277
0.38/0.16
20W T4.5
1700
2
1.0
3400
46
74
51910
51911
QTP1x39MH/UNV-F
QTP1x39MH/UNV-J
120-277
0.39/0.17
39W T6
3400
1
1.0
3400
44
77
51970 QTP2X39MH UNV F
51971 QTP2X39MH UNV J
120-277
0.75/0.33
39W T6
3400
2
1.0
6800
89
76
51912 QTP1x70MH/UNV-F
51913 QTP1x70MH/UNV-J
120-277
0.67/0.29
70W T6
6700
1
1.0
6700
79
85
51914 QTP1x100MH/UNV-F
51915 QTP1x100MH/UNV-J
120-277
0.96/0.41
100W E17
9000
1
1.0
9000
110
82
74
QUICKTRONIC MH
Electronic Metal Halide
51958 QT1x20MH 120V SLIM
51959 QT1x20MH UNV SQ
51960 QT1x39MH 120V SLIM
51961 QT1x39MH UNV SQ
51962 QT1x70MH 120V SLIM
120
0.20
20W T4.5
1700
1
1.0
1700
23
120-277
0.19/0.09
20W T4.5
1700
1
1.0
1700
23
74
120
0.38
39W T6
3400
1
1.0
3400
44
77
120-277
0.38/0.17
39W T6
3400
1
1.0
3400
44
77
120
0.64
70W T6
6700
1
1.0
6700
79
85
51963 QT1x70MH 120V SQ
120
0.64
70W T6
6700
1
1.0
6700
79
85
51930 QT1x150MH/UNV F
120-277
1.40/0.60
150W T7.5
15500
1
1.0
15500
167
93
51931 QT1x150MH/UNV J
120-277
1.40/0.60
150W T7.5
15500
1
1.0
15500
167
93
QUICKTRONIC HIGH EFFICIENCY MH
Electronic Metal Halide - 208-277V
51980 QHE1X200MH 208-277V
208-277
1.06/0.79
200W E39
19000
1
1.0
19000
215
88
51981 QHE1X250MH 208-277V
208-277
1.32/0.99
250W E39
23500
1
1.0
23500
269
87
51982 QHE1X320MH 208-277V
208-277
1.69/1.27
320W E39
32000
1
1.0
32000
344
93
51983 QHE1X350MH 208-277V
208-277
1.85/1.39
350W EX39
33000
1
1.0
33000
376
88
51984 QHE1X400MH 208-277V
208-277
2.12/1.58
400W E39
42000
1
1.0
42000
430
98
Also operates: For all of the above Metal Halide Ballasts, see Ballast Technology & Specification Guide for additional lamp types
✰ Preliminary Data – check with OSRAM SYLVANIA for detailed specifications.
184
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
❂ New Product. Contact OSRAM SYLVANIA for product availability.
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 185
LED Power Supplies
Item
Number
OSRAM SYLVANIA
Description
Nominal
Input
Voltage
(VAC)
Nominal
Input
Current
(Amps)
Output
Current
(mA)
Remote
Mounting
(ft)
Location
Rating
Dimming
Range
Control
Voltage
OPTOTRONIC® Electronic DRAGON Power Supplies
OSRAM Constant Current LED DRAGON Power Supplies (DC Output) - Contact OSRAM SYLVANIA for DRAGON™ LED module ordering information
AC Input
51524 =
OT3/120-240/350
120-240
(AC)
0.1A@120V
350
50
Dry
N/A
N/A
51525
OT9/100-120/350 E
100-120
(AC)
0.18A@120V
350
30
Dry+Damp
N/A
N/A
10-24 (DC)
1.1A@10V
0.5A@24V
350
30
Dry+Damp
100% to 0%
10V to 0V DC
DC Input
51526
Item
Number
OT9/10-24/350 DIM E
OSRAM SYLVANIA
Description
Nominal
Input
Voltage
(VAC)
Nominal
Input
Current
(Amps)
Output
Voltage
(Vdc)
Min.
Output
Power
(W)
OPTOTRONIC Electronic LED Power Supplies
OSRAM LED Power Supplies (DC Output) - 10.5 V DC 100-120
0.120@120V 10.5±0.5
Max.
Output
Power
(W)
Max.
Line
Ripple
(V)
Remote
Mounting
(ft)
With
OT9
Dim
Compatible
With
With
OT
OT RGB
Dim
Controls
Location
Rating
Contact OSRAM SYLVANIA for LED (Light Emitting Diodes) ordering information
51502 =
OT6/100-120/10CE
0.4
6
±0.2V
32
YES
YES
YES
51505
OT25/120/10
120
0.26@120V
10.5±1.0
3
25
±1.1V
10
NO
NO
NO
Dry
51508
OT50/120/10
120
0.52@120V
10.5±1.0
10
50
±1.1V
8
NO
NO
NO
Dry+Damp
51509
OT50/120-277/10E
120-277
0.51@120V
0.22@277V
10.5±1.0
0.4
50
±0.2V
32
YES
YES
YES
Dry+Damp
51506
OT25/120/10CORD
120
0.42@120V
10.5±0.5
0.5
25
±0.5V
58
YES
YES
YES
Dry+Damp
OSRAM LED Power Supplies (DC Output) - 24 V DC -
Dry+Damp
Contact OSRAM SYLVANIA for LED (Light Emitting Diodes) ordering information
51503 =
OT6/100-120/24CE
100-120
0.15@120V
24.0±0.5
0.9
6
±0.4V
32
YES
YES
YES
Dry+Damp
51512
OT20/120-240/24S
120-240
0.35@120V
0.23@240V
24.0±0.5
0.9
20
±0.2V
32
YES
YES
YES
Dry
51513
OT75/120/24
120
1.2@120V
24.0±0.5
10
75
±1.0V
30
YES
NO
YES
Dry+Damp
51514
OT75/120-277/24E
120-277
0.75@120V
0.32@277V
24.0±0.5
0.9
75
±0.2V
32
YES
YES
YES
Dry+Damp
51511 =
OT96/120-277/24
120-277
0.91@120V
0.39@277V
24.0±0.5
0.8
96
±1.0V
10
YES
YES
YES
WET
51515 =
OT240/120-240/24/CH3 120-240
2.39@120V
1.19@240V
24.0±0.5
0.8
240
±1.0V
10
YES
YES
YES
WET
Item
Number
OSRAM SYLVANIA
Description
Nominal
Input
Voltage
(VDC)
Max.
Input
Current
(A)
Control
Voltage
(VDC)
Output
Power
per channel
(W)
Max.
Output
Power
(W)
Max.
Power
Loss
(W)
Max. Output
Current
per channel
(A)
OPTOTRONIC Electronic LED Dim/Sequencer Modules
OSRAM LED Dim/Sequencer Modules - OTRGB operates in conjunction with the LED power supplies listed above
51517
51518
Item
Number
OT RGB DIM
OT RGB SEQUENCER
10.5 / 24
6
0-10
OSRAM SYLVANIA
Description
Nominal
Input
Voltage
(VDC)
Nominal
Input
Current
(A)
Control
Voltage
(VDC)
0-21 / 0-48
Max.
Output
Power
(W)
60 / 140
4
2
Max.
Output
Current
(A)
OPTOTRONIC Electronic LED Dimming Modules
OSRAM LED Dimming Modules - OTDIM operates in conjunction with the LED power supplies listed above
51516
OT DIM
10.5
24
5.3
5.3
0-10VDC
0-10VDC
0–52.5
0–120
5
5
Complete performance data is available in the SYLVANIA QUICKTRONIC®
LED Systems Specification Guide and at www.sylvania.com.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
❂ New Product. Contact OSRAM SYLVANIA for product availability.
185
LL
EE
DD
PP
OO
WW
EE
RR
SS
UU
PP
PP
LL
II
EE
SS
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 186
Discontinued Electronic Ballasts: Nearest Equivalent SYLVANIA Replacement
DISCONTINUED BALLASTS
Item
OSRAM SYLVANIA
Number
Description
T8, 1-Lamp, Instant Start
ISN
ISL
49911
49912
49951
49952
49811
49812
49901
49931
49932
QT1X32T8/120 ISN-SC
QT1X32T8/277 ISN-SC
QT1X32T8/120 ISN-SC-PAL
QT1X32T8/277 ISN-SC-PAL
QT1X32T8/120 ISN-SC SRNK
QT1X32T8/277 ISN-SC SRNK
QTP 1x32T8/UNV ISN-SC SRNK
QT1X32T8/120 ISL-SC
QT1X32T8/277 ISL-SC
49701
QTP1X32T8/UNV-ISL-SC-SRNK
NEAREST REPLACEMENT UNIVERSAL VOLTAGE BALLASTS
Item
OSRAM SYLVANIA
Number
Description
49941
QTP 1x32T8/UNV ISN-SC
49942
QTP 1x32T8/UNV ISN-SC-PAL
49905
QTP 1x32T8/UNV-ISN-SC-B
49741
QTP 1x32T8/UNV ISL-SC
49832
QTP 1x32T8/UNV-ISL-SC-B
49943
QTP 2x32T8/UNV ISN-SC
49944
QTP 2x32T8/UNV ISN-SC-PAL
49906
QTP 2x32T8/UNV-ISN-SC-B
49743
QTP 2x32T8/UNV ISL-SC
49744
QTP 2x32T8/UNV ISL-SC-PAL
49834
QTP 2x32T8/UNV-ISL-SC-B
49843
QTP 2x32T8/UNV ISH-SC
49844
QTP 2x32T8/UNV ISH-SC-PAL
49945
QTP 3x32T8/UNV ISN-SC
49946
QTP 3x32T8/UNV ISN-SC-PAL
49907
QTP 3x32T8/UNV-ISN-SC-B
T8, 2-Lamp, Instant Start
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
ISN
ISL
ISH
49913
49914
49953
49954
49813
49814
49902
49933
49934
49823
49803
49804
49702
49923
49924
49973
49974
QT2X32T8/120 ISN-SC
QT2X32T8/277 ISN-SC
QT2X32T8/120 ISN-SC-PAL
QT2X32T8/277 ISN-SC-PAL
QT2X32T8/120 ISN-SC SRNK
QT2X32T8/277 ISN-SC SRNK
QTP 2x32T8/UNV ISN-SC SRNK
QT2X32T8/120 ISL-SC
QT2X32T8/277 ISL-SC
QT2X32T8120ISLSCPAL
QT2X32T8/120 ISL-SC SRNK
QT2X32T8/277 ISL-SC SRNK
QTP 2x32T8/UNV-ISL-SC-SRNK
QT2X32T8/120 ISH-SC
QT2X32T8/277 ISH-SC
QT2X32T8/120 ISH-SC-PAL
QT2X32T8/277 ISH-SC-PAL
T8, 3-Lamp, Instant Start
ISN
ISL
ISH
49915
49916
49955
49956
49815
49816
49903
49935
49936
49825
49805
49806
49703
49525
49526
QT3X32T8/120 ISN-SC
QT3X32T8/277 ISN-SC
QT3X32T8/120 ISN-SC-PAL
QT3X32T8/277 ISN-SC-PAL
QT3X32T8/120 ISN-SC SRNK
QT3X32T8/277 ISN-SC SRNK
QTP 3x32T8/UNV-ISN-SC SRNK
QT3X32T8/120 ISL-SC
QT3X32T8/277 ISL-SC
QT3X32T8120T8ISLSCPAL
QT3X32T8/120 ISL-SC SRNK
QT3X32T8/277 ISL-SC SRNK
QTP 3x32T8/UNV-ISL-SC-SRNK
QT3x32/120 PLUS
QT3x32/277 PLUS
49745
QTP 3x32T8/UNV ISL-SC
49746
QTP 3x32T8/UNV ISL-SC-PAL
49835
QTP 3x32T8/UNV-ISL-SC-B
49845
QTP 3x32T8/UNV ISH-SC
49947
QTP 4x32T8/UNV ISN-SC
49948
QTP 4x32T8/UNV ISN-SC-PAL
49908
QTP 4x32T8/UNV-ISN-SC-B
49747
QTP 4x32T8/UNV ISL-SC
49836
QTP 4x32T8/UNV-ISL-SC-B
49877
49878
QHE 4X32T8/UNV ISH
QHE 4X32T8/UNV ISH-PAL
51400
QTP 1x32T8/UNV PSN-TC
51401
QTP 1x32T8/UNV PSN-TC-PAL
51405
QTP 2x32T8/UNV PSN-TC
51406
QTP 2x32T8/UNV PSN-TC-PAL
T8, 4-Lamp, Instant Start
ISN
ISL
ISH
49917
49918
49517
49957
49958
49557
49817
49818
49904
49537
49538
49307
49308
49704
49521
49522
QT4X32T8/120 ISN-SC
QT4X32T8/277 ISN-SC
QT4X32120 IS
QT4X32T8/120 ISN-SC-PAL
QT4X32T8/277 ISN-SC-PAL
QT4X32120-PAL
QT4X32T8/120 ISN-SC SRNK
QT4X32T8/277 ISN-SC SRNK
QTP4x32T8/UNV-ISN-SC SRNK
QT4X32/120 LP
QT4X32/277 LP
QT4X32/120 LP SRNK
QT4X32/277 LP SRNK
QTP4x32T8/UNV-ISL-SC-SRNK
QHE4x32T8/277 ISH
QHE4x32T8/277 ISH-PAL
T8, 1-Lamp, Programmed Start
PSN
50804
50806
50805
50807
QTP1X32T8/120 PSN-TC
QTP1X32T8/277 PSN-TC
QTP1X32T8/120 PSN-TC-PAL
QTP1X32T8/277 PSN-TC-PAL
T8, 2-Lamp, Programmed Start
PSN
186
50814
50824
50815
50825
QTP2X32T8/120 PSN-SC
QTP2X32T8/277 PSN-SC
QTP2X32T8/120 PSN-SC-PAL
QTP2X32T8/277 PSN-SC-PAL
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 187
Discontinued Electronic Ballasts: Nearest Equivalent SYLVANIA Replacement
DISCONTINUED BALLASTS
Item
OSRAM SYLVANIA
Number
Description
T8, 3-Lamp, Programmed Start
PSN
50830
50840
50832
50842
QTP3X32T8/120 PSN-SC
QTP3X32T8/277 PSN-SC
QTP3X32T8/120 PSN-SC-PAL
QTP3X32T8/277 PSN-SC-PAL
NEAREST REPLACEMENT UNIVERSAL VOLTAGE BALLASTS
Item
OSRAM SYLVANIA
Number
Description
51410
QTP 3x32T8/UNV PSN-SC
51411
QTP 3x32T8/UNV PSN-SC-PAL
51415
QTP 4x32T8/UNV PSN-SC
51416
QTP 4x32T8/UNV PSN-SC-PAL
49598
QTP 2x59T8/UNV ISN-SC
49599
QTP 2x59T8/UNV ISN-SC-PAL
T8, 4-Lamp, Programmed Start
PSN
50850
50860
50852
50862
QTP4X32T8/120 PSN-SC
QTP4X32T8/277 PSN-SC
QTP4X32T8/120 PSN-SC-PAL
QTP4X32T8/277 PSN-SC-PAL
8' T8, 2-Lamp, Instant Start
ISN
ISH
49581
49582
49585
49586
49587
49588
49028
49597
49583
49584
QT2X59T8/120 IS
QT2X59T8/277 IS
QT2X59T8/120 IS-PAL
QT2X59T8/277 IS-PAL
QT2X59T8/120 IS-SRNK
QT2X59T8/277 IS-SRNK
QT2X59T8/120 IS-SRNK-IN 4Pk
QTP2x59T8/UNV ISN-SC-SRNK
QT2X59T8/120 PLUS
QT2X59T8/277 PLUS
49590
QTP 2x59T8/UNV-ISN-SC-B
49879
QHE 2X59T8/UNV ISH
QTP 1x54T5HO/UNV PSN
49131
QTP 2x54T5HO/UNV PSN
QT 1X40/120 DL
QT 1X40/277 DL
49428
QHE 1x40DL/UNV ISN-SC
QT 2X40/120 DL
QT 2X40/277 DL
49429
QHE 2x40DL/UNV ISN-SC
QT 3X40/120 DL
QT 3X40/277 DL
49430
QHE 3x40DL/UNV ISN-SC
QTP 1/2x13CF/UNV QS
QTP 1/2x18CF/UNV QS
QTP 2x26CF/UNV QS
QTP 1/2x13CF/UNV DS
QTP 1/2x18CF/UNV DS
QTP 2x26/1x42/32CF/UNV DS
QTP 2x26/1x42/32CF/UNV DM
51818
51823
51833
51850
51851
51852
51853
QTP 1/2x13CF/UNV
QTP 1/2x18CF/UNV
QTP 2x26CF/UNV
QTP 1/2x13CF/UNV Kit
QTP 1/2x18CF/UNV Kit
QTP 2x26/1x42/32CF/UNV Kit
QTP 2x26/1x42/32CF/UNV M Kit
QTP 1x32T8/120 DIM5-B
QTP 1x32T8/120 DIM5-B NL
QTP 1x32T8/277 DIM5-B
QTP 1x32T8/277 DIM5-B NL
50705
QTP 1x32T8/UNV DIM-TC
QTP 2x32T8/120 DIM5-B
QTP 2x32T8/120 DIM5-B NL
QTP 2x32T8/277 DIM5-B
QTP 2x32T8/277 DIM5-B NL
50707
QTP 2x32T8/UNV DIM-TC
QTP 3x32T8/120 DIM5-B
QTP 3x32T8/120 DIM5-B NL
QTP 3x32T8/277 DIM5-B
QTP 3x32T8/277 DIM5-B NL
50714
QTP 3x32T8/UNV DIM-TCL
QTP 4x32T8/120 DIM10-Q
QTP 4x32T8/120 DIM10-Q NL
QTP 4x32T8/277 DIM10-Q
QTP 4x32T8/277 DIM10-Q NL
50716
QTP 4x32T8/UNV DIM-TCL
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
T5HO, 1-Lamp, Programmed Start
49121
FT40T5, 1-Lamp, Instant Start
ISN
49641
49642
FT40T5, 2-Lamp, Instant Start
ISN
49643
49644
FT40T5, 3-Lamp, Instant Start
ISN
49645
49646
T4, 1 and 2-Lamp, Programmed Rapid Start
51778
51783
51793
51810
51811
51812
51813
T8, 1-Lamp, Dimming Systems
50700
50701
50710
50711
T8, 2-Lamp, Dimming Systems
50720
50721
50730
50731
T8, 3-Lamp, Dimming Systems
50750
50751
50760
50761
T8, 4-Lamp, Dimming Systems
50770
50771
50780
50781
T2, 1 and 2-Lamp, Programmed Start
49734
QT-FM
(Replacement Ballasts are 120V, 1-Lamp)
49735
49736
QT1X6-8FM/120 (120V, 1 LAMP ONLY)
QT1X11-13FM/120 (120V, 1 LAMP ONLY)
51502
OT6/100-120/10CE
51503
OT6/100-120/24CE
LED Power Supplies (DC Output), 10V DC
51500
OT6/100-240/10COS
LED Power Supplies (DC Output), 24V DC
51501
OT6/100-240/24COS
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
187
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 188
Electronic Ballast
Cross Reference Guide
QUICKCROSS
Item
Number
The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition.
OSRAM SYLVANIA
Advance
U.L.T.
Universal Lighting Technologies
(formerly Magnetek)
GE
Howard
QUICKTRONIC HIGH EFFICIENCY 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS
32 T8 High Efficiency Instant Start - Low Ballast Factor - Small Can - <10% THD
49861
QHE 1X32T8/UNV ISL-SC
IOP-1P32-LW-SC
B132IUNVEL-A
GE-132-MAX-L/ULTRA
N/A
49863
QHE 2X32T8/UNV ISL-SC
IOP-2P32-LW-SC
B232IUNVEL-A
GE-232-MAX-L/ULTRA
N/A
49865
QHE 3X32T8/UNV ISL-SC
IOP-3P32-LW-SC
B332IUNVEL-A
GE-332-MAX-L/ULTRA
N/A
49867
QHE 4X32T8/UNV ISL-SC
IOP-4P32-LW-SC
B432IUNVEL-A
GE-432-MAX-L/ULTRA
N/A
32 T8 High Efficiency Instant Start - Normal Ballast Factor - Small Can - <10% THD
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
49851
QHE 1X32T8/UNV ISN-SC
IOP-1P32-SC
B132IUNVHE-A
GE-132-MAX-N/ULTRA
N/A
49853
QHE 2X32T8/UNV ISN-SC
IOP-2P32-SC
B232IUNVHE-A
GE-232-MAX-N/ULTRA
N/A
49855
QHE 3X32T8/UNV ISN-SC
IOP-3P32-SC
B332IUNVHE-A
GE-332-MAX-N/ULTRA
N/A
49857
QHE 4X32T8/UNV ISN-SC
IOP-4P32-SC
B432IUNVHE-A
GE-432-MAX-N/ULTRA
N/A
32 T8 High Efficiency Instant Start - High Ballast Factor - Small Can - <10% THD
49871
QHE 1X32T8/UNV ISH-SC
IOP-1P32-HL-SC
N/A
N/A
N/A
49873
QHE 2X32T8/UNV ISH-SC
IOP-2P32-HL-SC
B232IUNVHEH-A
GE-232-MAX-H/ULTRA
N/A
49875
QHE 3X32T8/UNV ISH-SC
IOP-3P32-HL-90C-SC
B332IUNVHEH-A
GE-332-MAX-H/ULTRA
N/A
49877
QHE 4X32T8/UNV ISH
IOP-4P32-HL-90C-G
N/A
GE-432-MAX-H/ULTRA
N/A
QUICKTRONIC PROFESSIONAL 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS
32 T8 Instant Start - Low Ballast Factor - Small Can - <10%THD
49741
QTP 1x32T8/UNV ISL-SC
ICN-1P32-LWSC
N/A
N/A
EPL1/32IS/120-277
49743
QTP 2x32T8/UNV ISL-SC
ICN-2P32-LWSC
N/A
GE-232-MV-L
EPL2/32IS/120-277
49745
QTP 3x32T8/UNV ISL-SC
ICN-3P32-LWSC
N/A
GE-332-MV-L
EPL3/32IS/120-277
49747
QTP 4x32T8/UNV ISL-SC
ICN-4P32-LWSC
N/A
GE-432-MV-L
EPL4/32IS/120-277
32 T8 Instant Start - Normal Ballast Factor - Small Can - <10% THD
49941
QTP 1x32T8/UNV ISN-SC
ICN-1P32-SC
B132IUNVHP-B
GE-132-MV-N
EP1/32IS/120-277
49943
QTP 2x32T8/UNV ISN-SC
ICN-2P32-SC
B232IUNVHP-B
GE-232-MV-N
EP2/32IS/120-277
49945
QTP 3x32T8/UNV ISN-SC
ICN-3P32-SC
B332IUNVHP-A
GE-332-MV-N
EP3/32IS/120-277
49947
QTP 4x32T8/UNV ISN-SC
ICN-4P32-SC
B432IUNVHP-A
GE-432-MV-N
EP4/32IS/120-277
32 T8 Instant Start - High Ballast Factor - Small Can - <10% THD
49841
QTP 1x32T8/UNV ISH-SC
N/A
N/A
N/A
N/A
49843
QTP 2x32T8/UNV ISH-SC
N/A
N/A
GE-232-MV-H
N/A
49845
QTP 3x32T8/UNV ISH-SC
N/A
N/A
GE-332-MV-H
N/A
QUICKTRONIC 32 T8
PROStart®
PSX UNIVERSAL VOLTAGE SYSTEMS
32 T8 Programmed Rapid Start - High Efficiency - Low Ballast Factor - <10%THD
51420
QTP 1x32T8/UNV PSX-TC
IOP-1S32-LW-SC
N/A
N/A
N/A
51425
QTP 2x32T8/UNV PSX-TC
IOP-2S32-LW-SC
N/A
N/A
N/A
51430
QTP 3x32T8/UNV PSX-SC
IOP-3S32-LW-SC
N/A
N/A
N/A
51435
QTP 4x32T8/UNV PSX-SC
IOP-4S32-LW-SC
N/A
N/A
N/A
QUICKTRONIC PROFESSIONAL 32 T8 PROStart PSN UNIVERSAL VOLTAGE SYSTEMS
32 T8 Programmed Rapid Start - Normal Ballast Factor - <10%THD
51400
QTP 1x32T8/UNVPSN-TC
IOP-1S32-SC
B132PUNVHP-A
N/A
N/A
51405
QTP 2x32T8/UNVPSN-TC
IOP-2S32-SC
B232PUNVHP-A
N/A
N/A
51410
QTP 3x32T8/UNVPSN-SC
IOP-3S32-SC
B332PUNVHP-A
N/A
N/A
51415
QTP 4x32T8/UNVPSN-SC
IOP-4S32-SC
B432PUNVHP-A
N/A
N/A
188
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 189
Electronic Ballast
Cross Reference Guide
The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition.
Item
Number
OSRAM SYLVANIA
U.L.T.
Universal Lighting Technologies
(formerly Magnetek)
Advance
QUICKTRONIC HIGH EFFICIENCY 32 T8
PROStart®
QUICKCROSS
GE
Howard
UNIVERSAL VOLTAGE SYSTEMS
32 T8 Programmed Rapid Start - High Ballast Factor (90°C Case Temperature - Parallel Operation)
49450
QHE2x32T8/UNV-PSH-HT
N/A
N/A
GE-232-MV-PS-H
N/A
49453
QHE3x32T8/UNV-PSH-HT
N/A
N/A
GE-332-MV-PS-H
N/A
49455
QHE4x32T8/UNV-PSH-HT
N/A
N/A
GE-432-MV-PS-H
N/A
QUICKTRONIC HIGH EFFICIENCY 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS
32 T8 Instant Start - Normal Ballast Factor - UL Type CC - Lamp Striation Control/LSC
49381
QHE1x32T8/UNV-ISN-SC-1
IOP-1P32-SC
N/A
GE-132-MAX-N/ULTRA
N/A
49383
QHE2x32T8/UNV-ISN-SC-1
IOP-2P32-SC
N/A
GE-232-MAX-N/ULTRA
N/A
49385
QHE3x32T8/UNV-ISN-SC-1
IOP-3P32-SC
N/A
GE-332-MAX-N/ULTRA
N/A
49387
QHE4x32T8/UNV-ISN-SC-1
IOP-4P32-SC
N/A
GE-432-MAX-N/ULTRA
N/A
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
QUICKTRONIC HIGH EFFICIENCY 59 T8 & QUICKTRONIC PROFESSIONAL 8 FOOT UNIVERSAL VOLTAGE
59W F96 T8 Instant Start - Low Ballast Factor - <10% THD
50239
QHE 2x59T8/UNV-ISL-SC
N/A
N/A
N/A
N/A
N/A
GE-259-MAX-N/ULTRA
N/A
N/A
N/A
N/A
B259IUNVHP-A
GE-259-MV-N
N/A
59W F96 T8 Instant Start - Normal Ballast Factor - <10% THD
49859
QHE 2x59T8/UNV-ISN-SC
IOP-2P59-SC
59W F96 T8 Instant Start - High Ballast Factor - <10% THD
49879
QHE 2x59T8/UNV-ISH
N/A
59W F96 T8 Instant Start - Normal Ballast Factor - <10% THD - Universal Voltage
49598
QTP 2X59T8/UNV ISN-SC
N/A
QUICKTRONIC HIGH EFFICIENCY 86 T8/HO (8 FOOT) PROSTART UNIVERSAL VOLTAGE SYSTEMS
86W F96 T8/HO (8 foot) PROStart® - Normal Ballast Factor -(90°C Case Temperature - Parallel Operation)
50304
QHE 2x86T8HO/UNV-PSN-HT-SCL
ICN-2S86
N/A
N/A
N/A
QUICKTRONIC HIGH EFFICIENCY, PROFESSIONAL & T8 INSTANT START 347 VOLT - CANADA
32 T8 High Efficiency Instant Start- Normal Ballast Factor - Small Can - <10% THD
49461
QHE 1x32T8/347 ISN-SC
N/A
N/A
N/A
N/A
49463
QHE 2x32T8/347 ISN-SC
N/A
N/A
N/A
N/A
49465
QHE 3x32T8/347 ISN-SC
N/A
N/A
N/A
N/A
49467
QHE 4x32T8/347 ISN-SC
N/A
N/A
N/A
N/A
32 T8 High Efficiency Instant Start- Low Ballast Factor - Small Can - <10% THD
49471
QHE 1x32T8/347 ISL-SC
N/A
N/A
N/A
N/A
49473
QHE 2x32T8/347 ISL-SC
N/A
N/A
N/A
N/A
49475
QHE 3x32T8/347 ISL-SC
N/A
N/A
N/A
N/A
49477
QHE 4x32T8/347 ISL-SC
N/A
N/A
N/A
N/A
32 T8 Instant Start- Normal Ballast Factor - Small Can - <10% THD
49711
QTP 1x32T8/347 ISN-SC
N/A
N/A
N/A
N/A
49713
QTP 2x32T8/347 ISN-SC
N/A
B2321347HP-A
N/A
N/A
32 T8 Instant Start- Low Ballast Factor - Small Can - <20% THD - Small Can/Standard "F" Can
49241
QT 2x32T8/347 ISL-SC
GEL-2P32-LW-RH-TP (F-Can)
B2321347L-A
N/A
N/A
49939
QT 4x32T8/347 ISL-SC
N/A
N/A
N/A
N/A
32 T8 Instant Start- Normal Ballast Factor - Small Can - <20% THD - Small Can/Standard "F" Can
49993
QT 3x32T8/347 ISN-SC
GEL-3P32-RH-TP (F-Can)
B3321347RH (F-Can)
N/A
E3/32IS/347 (F-Can)
49994
QT 4x32T8/347 ISN-SC
GEL-4P32-RH-TP (F-Can)
B4321347RH (F-Can)
N/A
E4/32IS-347 (F-Can)
N/A
N/A
N/A
N/A
N/A
N/A
32 T8 Instant Start- High Ballast Factor - Small Can - <20% THD
49927
QT 2x32T8/347 ISH-SC
N/A
QUICKTRONIC 59 T8 8 FOOT SYSTEM - 347 VOLT - CANADA
59W F96 T8 Instant Start - Normal Ballast Factor - <20% THD
49217
QT2x59/347IS
GEL-2P59
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
189
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 190
Electronic Ballast
Cross Reference Guide
QUICKCROSS
Item
Number
The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition.
OSRAM SYLVANIA
U.L.T.
Universal Lighting Technologies
(formerly Magnetek)
Advance
QUICKTRONIC PROFESSIONAL T5HO
PROStart®
Howard
UNIVERSAL VOLTAGE SYSTEMS
T5 HO - Normal Ballast Factor - <10% THD - (Ballast Can Size varies between manufacturers - please refer to specifications for details)
49111
49111
49111
49111
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
49131
49151
QTP2x39-24T5HO/UNVPSN (1 Lamp)
(14.17"L x 1.18"W x 0.87"H)
(Mounting 13.74")
QTP2x39-24T5HO/UNVPSN (FP39T5HO)
(14.17"L x 1.18"W x 0.87"H)
(Mounting 13.74")
QTP2x39-24T5HO/UNVPSN (1 Lamp)
(14.17"L x 1.18"W x 0.87"H)
(Mounting 13.74")
QTP2x39-24T5HO/UNVPSN (FP24T5HO)
(14.17"L x 1.18"W x 0.87"H)
(Mounting 13.74")
QTP2x54T5HO/UNVPSN
(16.73"L x 1.18"W x 0.87"H)
(Mounting 16.34")
QTP1x80T5HO/UNVPSN
(14.17"L x 1.18"W x 0.87"H)
(Mounting 13.74")
ICN-2S39 (1 Lamp)
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
ICN-2S39
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
ICN-2S24 (1 Lamp)
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
ICN-2S24
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
ICN-2S54
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
ICN-1S80
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
B239PUNV-D (1 Lamp)
(16.88"L x 1.18"W x 1.0"H)
(Mounting 16.28")
B239PUNV-D
(16.88"L x 1.18"W x 1.0"H)
(Mounting 16.28")
B224PUNV-C (1 Lamp)
(14.25"L x 1.18"W x 1.0"H)
(Mounting 13.75")
B224PUNV-C
(14.25"L x 1.18"W x 1.0"H)
(Mounting 13.75")
B254PUNV-D
(16.88"L x 1.18"W x 1.0"H)
(Mounting 16.28")
ES4515K
(16.65"L x 1.24"W x 1.0"H)
(Mounting 16.3")
N/A
N/A
N/A
N/A
EP2/54HO/PRS/120-277
(16.7"L x 1.18"W x 1.0"H)
N/A
QUICKTRONIC PROFESSIONAL T5 PROStart UNIVERSAL VOLTAGE SYSTEMS
28W T5 - Normal Ballast Factor - <10% THD - (Ballast Can Size varies between manufacturers - please refer to specifications for details)
49181
49181
QTP2x28T5/UNVPSN (1 Lamp)
QTP2x28T5/UNVPSN
(14.17"L x 1.18"W x 0.87"H)
(Mounting 13.74")
ICN-2S28 (1 Lamp)
ICN-2S28
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
B228PUNV-C (1 Lamp)
B228PUNV-C
(14.25"L x 1.18"W x 1.0"H)
(Mounting 13.75")
N/A
N/A
QUICKTRONIC PROStart T5HO UNIVERSAL High Ambient Temp.
T5 HO - Normal Ballast Factor - <10% THD - (Ballast Can Size varies between manufacturers - please refer to specifications for details)
49136
QTP 2x54T5HO/UNV PSN HT
ICN-2S54-90C
B254PUNV-D
EP2/54HO/PRS/MV/90C
T5 HO - Normal Ballast Factor - <10% THD - (Ballast Can Size varies between manufacturers - please refer to specifications for details)
49161
QTP 4x54T5HO/UNV PSN HTW
ICN-4S54-90C
B454PUNV-E
N/A
QUICKTRONIC PROStart T5HO 347-480V High Ambient Temp.
T5 HO - Normal Ballast Factor - <10% THD - (Ballast Can Size varies between manufacturers - please refer to specifications for details)
49146
Item
Number
QTP 2x54T5HO/347-480 PSN HT
(16.73"L x 1.18"W x 1.0"H)
(Mounting 16.34")
HCN-2S54-90C
(16.70"L x 1.18"W x 1.0"H)
(Mounting 16.34")
OSRAM SYLVANIA
Advance
B254PHRV-E
(16.88"L x 1.74"W x 1.18"H)
(Mounting 16.28")
U.L.T.
Universal Lighting Technologies
(formerly Magnetek)
N/A
GE
Howard
QUICKTRONIC HIGH EFFICIENCY INSTANT START DL40 UNIVERSAL VOLTAGE SYSTEMS
40W TT5 High Efficiency Instant Start - Small Can
49428
QHE 1x40DL/UNV ISN-SC
N/A
N/A
N/A
N/A
49429
QHE 2x40DL/UNV ISN-SC
N/A
N/A
N/A
N/A
49430
QHE 3x40DL/UNV ISN-SC
N/A
N/A
N/A
N/A
QUICKTRONIC PROFESSIONAL PROStart DL40
40W TT5 Programmed Rapid Start - Normal Ballast Factor - <10% THD
50320
QTP1x40TT5/120PSN-F
REL-1TTS40
C240PUNVHP-B (1 Lamp)
C240PUNVHP-B (1 Lamp)
N/A
50330
QTP1x40TT5/277PSN-F
VEL-1TTS40
C240PUNVHP-B (1 Lamp)
C240PUNVHP-B (1 Lamp)
N/A
50340
QTP2x40TT5/120PSN-F
REL-2TTS40
C240PUNVHP-B
C240PUNVHP-B
N/A
50350
QTP2x40TT5/277PSN-F
VEL-2TTS40
C240PUNVHP-B
C240PUNVHP-B
N/A
50360
QTP3x40TT5/120PSN-B
N/A
N/A
N/A
N/A
50370
QTP3x40TT5/277PSN-B
N/A
N/A
N/A
N/A
190
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 191
Electronic Ballast
Cross Reference Guide
The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition.
Item
Number
OSRAM SYLVANIA
Advance
U.L.T.
QUICKCROSS
ESI (Energy Savings Inc
is out of business)
Robertson
QUICKTRONIC PROFESSIONAL CF - UNIVERSAL VOLTAGE DUAL ENTRY
CF T4 PROStart® - Programmed Rapid Start - Normal Ballast Factor - <10%THD 1 CFL products run multiple lamp combinations and have various mounting/case styles - please refer to actual product specs.
51818
QTP 1/2x13CF/UNV
ICF-2S13-H1-LD
ES-2/1-CFQ-13/10-UNV-C
PSM213CQMVB
ICF-2S18-H1-LD
ICF-2S18-H1-LD
C213UNV-BE
C213UNV-SE
C218UNV-BE
C218UNV-SE
51823
QTP 1/2x18CF/UNV
ES-2/1-CFQ-18-UNV-C
ES-2/1-CFQ-18-UNV-D
PSM218CQMVB
PSM218CQMV
51833
QTP 2x26CF/UNV
ICF-2S26-H1-LD
C2642UNV-SE
ES-2/1-CFQ-26-UNV-D
PSG242TRMV
51898
QTP 2x26CF/UNV PEM
ICF-2S26-H1-LD
C2642UNV-SE
ES-2/1-CFQ-26-UNV-D
PSG242TRMV
51843
QTP 2x26/32/42CF/UNV M
ICF-2S42-M2-LS ICF- 2S42-M2-LD
C242UNV-BE
ES-2-CFH-42/32/26-UNV-H
PSG242TRMVB
51863
QTP 2x26/32/42CF/UNV M PEM
ICF-2S42-M2-BS
C242UNV-BES
N/A
PSG242TRMVBS
CF T4 PROStart - Programmed Rapid Start - Normal Ballast Factor - <10%THD 1 QTP CF models above replace shaded item numbers below.
CFL products run multiple lamp combinations and have various mounting/case styles - please refer to actual product specs.
51718
QTP1/2x13CF/UNVBS
ICF-2S13-H1-LD
C213UNV-BE
ES-2/1-CFQ-13/10-UNV-C
PSM213CQMVB
51748
QTP1/2x13CF/UNVTS
ICF-2S13-H1-LD
C213UNV-SE
ES-2/1-CFQ-13/10-UNV-D
PSM213CQMV
51723
QTP1/2x18CF/UNVBS
ICF-2S18-H1-LD
C218UNV-BE
ES-2/1-CFQ-18-UNV-C
PSM218CQMVB
51753
QTP1/2x18CF/UNVTS
ICF-2S18-H1-LD
C218UNV-SE
ES-2/1-CFQ-18-UNV-D
PSM218CQMV
51733
QTP2x26CF/UNVBS
ICF-2S26-H1-LD
C2642UNV-BE
ES-2/1-CFQ-26-UNV-C
PSG242TRMVB
51763
QTP2x26CF/UNVTS
ICF-2S26-H1-LD
C2642UNV-SE
ES-2/1-CFQ-26-UNV-D
PSG242TRMV
51743
QTP2x26/32/42CF/UNVBM
ICF-2S42-M2-LS
C242UNV-BE
ES-2-CFH-42/32/26-UNV-H
PSG242TRMVB
51803
QTP2x26/32/42CF/UNVPM
ICF-2S42-M2-BS
C242UNV-BES
N/A
PSG242TRMVBS
51773
QTP2x26/32/42CF/UNVTM
ICF-2S42-M2-LD
C242UNV-SE
ES-2-CFH-42/32/26-UNV-G
N/A
51740
QTP1x57CF/UNVBM (1X57)
ICF-2S42-M2-LS
C242UNV-BE
N/A
N/A
51740
QTP1x57CF/UNVBM (1X70)
ICF-1Q70-M3-LD
C242UNV-BE
N/A
N/A
51800
QTP1x57CF/UNVPM (1X57)
ICF-2S42-M2-BS
C242UNV-BES
N/A
N/A
51800
QTP1x57CF/UNVPM (1X70)
ICF-1Q70-M3-BS
C242UNV-BES
N/A
N/A
Item
Number
OSRAM SYLVANIA
Advance
U.L.T.
Universal Lighting Technologies
(formerly Magnetek)
QUICKTRONIC PROFESSIONAL 40T12
40 T12 Rapid Start - Normal Ballast Factor - <10% THD
50684
QTP1x40T12/120RSN-SC
REL-1S40-SC (REL-1S40-RH-TP)
B140R120HP
50685
QTP1x40T12/277RSN-SC
VEL-2S40-SC (VEL-1S40-RH-TP)
B140R277HP
50686
QTP2x40T12/120RSN-SC
REL-2S40-SC , RCN-2S40, REL-2S40-RH-TP
B240R120HP
50687
QTP2x40T12/277RSN-SC
VEL-2S40-SC, VCN-2S40, VEL-2S40-RH-TP
B240R277HP
50688
QTP3x40T12/120RSN
REL-3S40-RH-TP
B340R120HP
50689
QTP3x40T12/277RSN
VEL-3S40-RH-TP
B340R277HP
QUICKTRONIC 8 foot T12 Systems
96 T12 Instant Start - Normal Ballast Factor - Large Can - <20% THD
49881
QT2x96/120IS
REL-2P60-S
B2601120RH
49882
QT2x96/277IS
VEL-2P75-S
B2601277RH
96 T12/HO Rapid Start - Normal Ballast Factor - Large Can - <20% THD
49883
QT2x96/120HO
REL-2S110
B295SR120HP
49884
QT2x96/277HO
VEL-2S110
B295SR277HP
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
191
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 192
Electronic Ballast
Cross Reference Guide
QUICKCROSS
Item
Number
OSRAM SYLVANIA
POWERSENSE®
(2 wire Powerline & 0-10V)
(120-277V)
The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition.
Advance
Mark 10 (2 wire)
Mark 7
Powerline
(0-10V)
(Dedicated Voltage) (120-277V)
U.L.T. (formerly Magnetek)
LUTRON
Universal Lighting Technologies
Tu-wire (Powerline) Eco-10 TVE (0-10V)
Ballastar (0-10V)
Superdim (0-10V)
Dedicated Voltage
(Dedicated Voltage)
(120-277V)
Models Only
QUICKTRONIC POWERSENSE T8 DIMMING UNIVERSAL VOLTAGE
32 T8 Dimming Systems - High Efficiency
REZ-132-SC (120V)
50705
QTP 1x32T8/UNV DIM-TC
VEZ-132-SC (277V)
REZ-2S32-SC(120V)
50707
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
QTP 2x32T8/UNV DIM-TC
VEZ-2S32-SC (277V)
B132R120V5
IZT- 132-SC
B132R277V5
B232SR120V5
IZT-2S32-SC
B232SR277V5
ES5821B
ES5835K
TVE-T832-120-1
2W-T832-120-1
TVE-T825-120-1
ES5833B
TVE-T817-120-1
ES5818K
TVE-T832-277-1
ES5822B
2W-T832-120-2
TVE-T832-120-2
ES5836K
TVE-T832-277-2
ES5834B
ES5817K
50714
QTP 3x32T8/UNV DIM-TCL
50716
QTP 4x32T8/UNV DIM-TCL
Item
Number
OSRAM SYLVANIA
POWERSENSE
(2 wire Powerline & 0-10V)
(120-277V)
REZ-3S32-SC (120V)
VEZ-3S32-SC (277V)
IZT-3S32-SC
B332SR120V5
TVE-T832-120-3
B332SR277V5
TVE-T832-277-3
N/A
IZT-4S32
B432P277V5-E
Advance
Mark 10 (2 wire)
Mark 7
Powerline
(0-10V)
(Dedicated Voltage) (120-277V)
U.L.T. (formerly Magnetek)
LUTRON
Universal Lighting Technologies
Tu-wire (Powerline) Eco-10 TVE (0-10V)
Ballastar (0-10V)
Superdim (0-10V)
Dedicated Voltage
(Dedicated Voltage)
(120-277V)
Models Only
QUICKTRONIC POWERSENSE T5 DIMMING UNIVERSAL VOLTAGE
28 T5 Dimming Systems - High Efficiency
50726
QTP 2x28T5/UNV DIM-TCL
N/A
N/A
ES5851K
E3 T514 C120 2
ES5861K
E3 T514 C 277 2
ES5847K
E3 T521 C 120 2
E3 T521 C 277 2
EC0-T528-120-2
ECO-T528-277-2
Item
Number
OSRAM SYLVANIA
QUICKTRONIC PROFESSIONAL 54 T5HO
U.L.T.
Universal Lighting Technologies
(formerly Magnetek)
Advance
HELIOS™
Lutron
DIMMING - A list of 0-10V controllers is available from OSRAM SYLVANIA
54 T5 HO Dimming Systems (0-10Vdc control) - 100-1% Dimming Range -<10% THD at full output, <20% THD at full dim
49671
QT1x54/120PHO-DIM
RZT-154
N/A
ECO T554-120-1
49672
QT1x54/277PHO-DIM
VZT-154
N/A
ECO T554-277-1
49673
QT2x54/120PHO-DIM
RZT-2S54
N/A
ECO T554-120-2
49674
QT2x54/277PHO-DIM
VZT-2S54
N/A
ECO T554-277-2
192
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 193
Electronic Ballast
Cross Reference Guide
The smart electronics in SYLVANIA QUICKTRONIC® ballasts allow them to outperform the competition.
Item
Number
OSRAM SYLVANIA
U.L.T.
Universal Lighting Technologies
(formerly Magnetek)
Advance
QUICKCROSS
AROMAT
Hatch
QUICKTRONIC PROFESSIONAL MH
METALARC® Metal Halide Universal Voltage - Operates Ceramic and Most Quartz MH Lamp
51908
QTP1X20MH/UNV F
N/A
N/A
M2012-27CK-5EUF
MC20-1-F-UNIU
51909
QTP1X20MH/UNV J
N/A
N/A
M2012-27CK-5EUJ
MC20-1-J-UNIU
51968
QTP2X20MH/UNV F
N/A
N/A
N/A
MC20-2-F-UNNU
51969
QTP2X20MH/UNV J
N/A
N/A
N/A
MC20-2-J-UNNU
51910
QTP1X39MH/UNV F
IMH-50-A-LF
N/A
M3912-27CK-5EUF
MC39-1-F-UNIU
51911
QTP1X39MH/UNV J
IMH-50-A-BLS
N/A
M3912-27CK-5EUJ
MC39-1-J-UNIU
51970
QTP2X39MH/UNV F
IMH-239-A-LF
N/A
N/A
MC39-2-F-UNNU
51971
QTP2X39MH/UNV J
IMH-239-A-BLS
N/A
N/A
MC39-2-J-UNNU
51912
QTP1X70MH/UNV F
IMH-70-D-LF
EC70UNVSE
M7012-27CK-5EUF
MC70-1-F-UNIU
51913
QTP1X70MH/UNV J
IMH-70-D-BLS
EC70UNVBS
M7012-27CK-5EUJ
MC70-1-F-UNIU
51914
QTP1X100MH/UNV F
IMH-100-D-LF
EC100UNVSE
M10012-27CK-5EUF
MC100-1-F-UNIU
51915
QTP1X100MH/UNV J
IMH-100-D-BLS
EC100UNVBS
M10012-27CK-5EUJ
MC100-1-J-UNIU
Item
Number
OSRAM SYLVANIA
Advance
Universal
Lighting Technologies
(formerly Magnetek)
AROMAT
Hatch
GE
Metrolight
Delta
Power
QUICKTRONIC MH
METALARC® Metal Halide
51958
QT1x20MH 120V SLIM
N/A
N/A
M2012CK-6EUN-F
MC20-1-F-120V
N/A
M20MH-UX-C
N/A
51959
QT1x20MH UNV SQ
N/A
N/A
M2012CK-6EU-F
MC20-1-F-UNNU
N/A
N/A
N/A
51960
QT1x39MH 120V SLIM
N/A
N/A
M3912CK-6EUN-F
N/A
N/A
M39MH-UX-C
N/A
51961
QT1x39MH UNV SQ
IMH-39-G-LF
N/A
M3912CK-6EU-F
MC39-1-F-UNNU
GEMH39-MSF-120
N/A
N/A
51962
QT1x70MH 120V SLIM
N/A
N/A
M7012CK-6EUN-F
MC70-1-F-120S
GEMH70-SLF-MV
N/A
N/A
51963
QT1x70MH 120V SQ
N/A
N/A
M7012CK-6EU-F
N/A
GEMH70-MSF-120
N/A
N/A
51930
QT1x150MH/UNV F
IMH-150-H-LF
EC150UNVASE
M15012-27CK-5EUN-F
N/A
N/A
M150MH-C-UX-US
N/A
51931
QT1x150MH/UNV J
IMH-150-H-BLS
EC150UNVABM
M15012-27CK-5EUN-J
N/A
N/A
M150MH-S-UX-US
N/A
Item
Number
OSRAM SYLVANIA
Advance
Universal
Lighting Technologies
(formerly Magnetek)
GE
Metrolight
Delta
Power
QUICKTRONIC HIGH EFFICIENCY MH
Electronic Metal Halide - 208-277V
51980
QHE1X200MH 208-277V
IMH-200-C-LF
N/A
N/A
N/A
BA200M1A77DQ
51981
QHE1X250MH 208-277V
N/A
EP250MRVASE
GE-MH-400-MAX-208-277
N/A
BA250M1A77DQ
51982
QHE1X320MH 208-277V
IZTEMH4003PS
EP320MRVASE
GE-MH-400-MAX-208-277
M320MH-3-US-C-ND
BA320M1A77DQ
51983
QHE1X350MH 208-277V
IZTEMH4003PS
EP350MRVASE
GE-MH-400-MAX-208-277
M350MH-3-US-C-ND
BA350M1A77DQ
51984
QHE1X400MH 208-277V
IZTEMH4003PS
EP400MRVASE
GE-MH-400-MAX-208-277
M400MH-3-US-C-ND
BA400M1A77DQ
Line voltage, case sizes, wiring diagrams and performance specifications may vary; please refer to manufacturer’s specifications.
PLEASE NOTE:
This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content.
Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications
appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
193
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
12/18/07
10:43 AM
Page 194
Magnetic Ballasts
Simplified Solutions
Magnetic Ballasts
OSRAM SYLVANIA is focused on
helping our customers understand
our products, and to simplifying
their use and applications. SYLVANIA
magnetic fluorescent product labels
include an industry first — a handy
cross-reference guide to help identify
the proper ballast for replacing
existing installed products. The line
voltage is also clearly identified to
ensure proper application, and our
shipping carton labels are also color
coded to indicate the voltage to help
avoid misapplication even before the
ballasts are out of the box.
OSRAM SYLVANIA offers a wide range of
Magnetic Ballast Products to support our
customers with SYLVANIA brand lighting
products. This array of products will allow
our customers a broad selection of
Magnetic ballasts to choose from to
operate their SYLVANIA brand lamps.
SYLVANIA Magnetic HID
ballast descriptions are
based on the corresponding
lamp description to make
lamp/ballast matching and
identification easier.
All fluorescent and HID
carton labels also identify
the corresponding
lamp/ballast matching
to make proper product
selection as clear and
as simple as possible.
• HID Magnetic SUPER 5 Kits
• Magnetic Fluorescent Sign Ballasts
• Pulse Start HID Ballasts
• F-Can HID Ballasts
• Indoor Enclosed HID Ballasts
Complete performance data is available
in the Magnetic Ballast Catalog and at
www.sylvania.com.
Magnetic Fluorescent Ballasts
High quality products for most general
applications - i.e. T12, T9, T8, and T5 lamps
Magnetic Fluorescent
Sign Ballasts
T12 high output magnetic ballasts for
sign applications are designed to meet
or exceed industry standards and requirements for the sign business.
Magnetic HID Ballasts
HID Magnetic Ballast Kits
Easy to use replacement kits for the range
of metal halide, pulse start metal halide,
high pressure sodium and mercury lamps.
Kits include core and coil, capacitors and
ignitors (where required), brackets and
mounting hardware.
Our SUPER 5 HID Kits have 120, 208,
240, 277 and 480V input voltage taps to
reduce the number of models in inventory.
F-Can HID Ballasts
F-Can ballasts for indoor applications
operate a range of metal halide, pulse
start metal halide and high pressure
sodium lamps with minimal noise.
METALARC® Indoor
Enclosed HID Ballasts
Indoor Enclosed ballasts for indoor applications where remote mounting is required.
194
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 195
Table of Contents – Magnetic Ballasts
Fluorescent Magnetic Ballasts................................................. 198-199
with Competitive Mfrs. Cross Reference
HID Magnetic Ballasts ............................................................. 200-205
with Competitive Mfrs. Cross Reference
Magnetic Ballasts
Magnetic Fluorescent Ballasts for T8, T12, T10, T9 & T5 lamps
F017T8 Rapid Start, High PF ...................................................................................... 198
F025T8 or F032T8 Rapid Start, High PF .................................................................... 198
F30T12 Rapid Start, High PF ...................................................................................... 198
F40T12 Rapid Start, High PF ...................................................................................... 198
F40T12 Rapid Start, Normal PF.................................................................................. 198
F96T12/HO Rapid Start, High PF .............................................................................. 198
T12/HO SIGN .............................................................................................................. 198
J-Box Cover ................................................................................................................ 199
F96T12/VHO Rapid Start, High PF ............................................................................ 199
FC8T9 Circline Rapid Start, Normal PF ...................................................................... 199
Ease of Use
The Magnetic section of the
Product Line Guide provides our
customers with OSRAM SYLVANIA
product information as well as
competitive manufacturers’ cross
reference catalog numbers. OSRAM
SYLVANIA is focused on providing
information to our customers, which
will aid in the selection of the appropriate ballast for the desired application. The manufacturer’s cross
reference will help identify the
proper ballast for the replacement
of existing installed products.
FC12T9 or FC16T9 Circline Rapid Start, Normal PF .................................................. 199
FC12T9 & FC16T9 Circline Rapid Start, High PF ...................................................... 199
F48T12 Instant Start, High PF .................................................................................... 199
F96T12 Instant Start, High PF .................................................................................... 199
F8T5 Preheat Start, Normal PF .................................................................................. 199
F20T12 Preheat Start, Normal PF .............................................................................. 199
F15T12 Trigger Start, Normal PF ................................................................................ 199
F20T12 Trigger Start, Normal PF ................................................................................ 199
Magnetic HID Core & Coil Ballasts
METALARC® Metal Halide Core & Coil Ballast Kits.................................................... 200
METALARC Pulse Start Metal Halide Core & Coil Ballast Kits............................ 200-201
LUMALUX® High Pressure Sodium Core & Coil Reactor .......................................... 202
LUMALUX High Pressure Sodium Core & Coil Ballast Kits ................................ 202-203
Mercury Core & Coil Ballast Kits ................................................................................ 204
OSRAM SYLVANIA customers can
rely on one source for information
on both lamps and ballasts. Having
one source for lamps and ballasts
reduces the time required for
sorting out technical details and
product specifications.
Magnetic HID F-Can Ballasts
METALARC Metal Halide F-Can ................................................................................ 203
METALARC Pulse Start Metal Halide F-Can .............................................................. 203
LUMALUX High Pressure Sodium F-Can .................................................................. 204
Magnetic HID Indoor Enclosed Ballasts
METALARC Metal Halide Indoor Enclosed ................................................................ 204
Magnetic Ballast Warranty
All SYLVANIA HID and Fluorescent
Sign Ballasts are guaranteed for up
to 2 years. SYLVANIA Fluorescent
Ballasts are guaranteed for up to
3 years. For Magnetic Ballast
Limited Warranty details, go to
www.sylvania.com
HID Magnetic Ballast Replacement Parts and Lamp & Ballast Kits
METALARC Metal Halide Lamp & Ballast Kits ........................................................ 205
LUMALUX High Pressure Sodium Lamp & Ballast Kits............................................ 205
Replacement Ignitors for SYLVANIA HID ballasts ...................................................... 205
Replacement Capacitors for SYLVANIA HID ballasts ................................................ 205
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
195
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 196
Energy Legislation Update
On April 1, 2005 the 2000 Federal Ballast Efficacy
ballast efficacy standards for ballasts capable of operating
Regulations were implemented to raise the minimum Ballast
full and reduced wattage F40T12, F40T12/U, F96T12 and
Efficacy Factor (BEF) for T12 fluorescent ballasts. The ruling
F96T12HO lamps have been set in EPAct 2005. The levels
affects only high power factor fluorescent ballasts for:
set deadlines for the cessation of production of inefficient
ballasts and the gradual phase out of replacement units.
• One or two F40T12 and F40T12/U lamps
operated on a 120 or 277V ballast
Listed below is the essential timetable for the 2000 Federal
Ballast Efficacy Regulations and EPAct 2005 for Fixture
• Two F96T12 lamps operated on a 120 or
Manufacturers, Residential Markets and Distributors
277V ballast
(Replacement Market).
• Two F96T12HO lamps operated on a 120
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
or 277V ballast
Residential Market
On August 8, 2005, the Energy Policy Act of 2005
T12 magnetic fluorescent normal power factor ballasts
designed for residential applications were not affected
(EPAct 2005) was signed. EPAct 2005 addresses ballasts
for reduced wattage T12 lamps not originally covered in the
original 2000 Federal Ballast Efficacy Regulations. Minimum
by either ruling. However, ballasts sold must be marked
“For Residential Use Only”.
FIXTURE MARKET (OEM)
2000 Federal Ballast
Efficacy Regulation
Action
EPAct 2005
2005 BEF Standards for
2009 BEF Standards for
Full-Wattage T12 Lamps
Energy-Saving T12 Lamps
(F40T12, F40T12/U, F96T12
(F40T12, F40T12/U, F96T12
and F96T12HO)
and F96T12HO)
April 1, 2005
July 1, 2009
July 1, 2005
October 1, 2009
April 1, 2006
July 1, 2010
Ballast manufacturers can no
longer make ballasts that do not
pass the new requirements for
use in new fixtures.
Ballast manufacturers cannot
sell ballasts that do not pass the
new requirements to U.S. fixture
manufacturers.
Fixture manufacturers cannot
sell fixtures that include ballasts
that do not pass the new
requirements.
196
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 197
DISTRIBUTOR /
REPLACEMENT MARKET
2000 Federal Ballast Efficacy Regulations
Ballast manufacturers can manufacture and sell to
distributors, fluorescent ballasts for Full-Wattage F40T12,
F40T12/U, F96T12 and F96T12HO that do not meet the
OSRAM SYLVANIA will continue to supply the
Magnetic Fluorescent Ballasts listed below for
T12 lamps until July 1, 2010 (for replacement
purposes only):
minimum Ballast Efficacy Factor (BEF) until July 1, 2010.
However, the ruling stipulates these ballasts must meet
OSRAM SYLVANIA
Description*
Page
#
48011
MB1x40/120RS-SRNK
198
48120
MB1x40/277RS-SRNK
198
48001
MB2x40/120RS-SRNK
198
48121
MB2x40/277RS-SRNK
198
48025
MB2x96/HO/120RS-SRNK
198
EPAct 2005
Magnetic Fluorescent Ballasts
48027
MB2x96/HO/277RS-SRNK
198
On July 1, 2009 EPAct 2005 states that ballast manufac-
48018
MB2x96/120IS-SRNK
199
turers can manufacture and sell to distributors, fluorescent
48126
MB2x96/277IS-SRNK
199
the following criteria:
• Ballasts must be marked
“For Replacement Use Only”
• Ballasts are only available
with short leads
• Ballasts are to be in packages
not exceeding ten ballasts
Item
#
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
ballasts for Energy-Saving F40T12, F40T12/U, F96T12 and
F96T12HO that do not meet the minimum Ballast Efficacy
Factor (BEF) until July 1, 2010. As of July 1, 2009 energysaving T12 ballasts manufactured and sold for replacement
use must also meet the requirements listed above.
Mercury Vapor Ballasts
EPACT 2005 also states that Mercury Vapor Ballasts
cannot be manufactured after January 1, 2008. Complete
*These ballasts
will all be labeled
“For Replacement Use Only”,
have shorter lead lengths and
are individually shrink-wrapped.
information on EPAct 2005 is available in The Impact of
EPAct 2005 brochure (SYLVANIA literature code:
EPACT2005) and at www.sylvania.com
OSRAM SYLVANIA is committed to understanding your lighting needs by offering
a variety of lighting solutions. For additional product or industry information contact
1-800-LIGHTBULB or visit our website at www.sylvania.com.
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
197
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 198
Magnetic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
No. of
Lamps
Lamp
Types
Input
Power
(Watts)1
Advance
Catalog # 2
Universal Lighting
Technologies*
Valmont
Catalog # 2
Catalog # 2
T8 RAPID START
F017T8 Rapid Start - High Power Factor
48312
MB1x17/120RS
120
1
F017T8, FB016T8/U
31
R1P817TP
707TCP
8G4177W
F032T8, FB032T8/U, FB031T8/U,
F025T8, FB024T8/U, F040T8
F032T8, FB032T8/U, FB031T8/U,
F025T8, FB024T8/U, F040T8
F032T8, FB032T8/U, FB031T8/U,
F025T8, FB024T8/U, F040T8
F032T8, FB032T8/U, FB031T8/U,
F025T8, FB024T8/U
F032T8, FB032T8/U, FB031T8/U,
F025T8, FB024T8/U
35
---
M132R1204
---
44
R1P825TP4 &
R1P32TP Mark III4
V1P825TP4 &
V1P32TP Mark III4
R2P825TP4 &
R2P32TP Mark III4
V2P825TP4 &
V2P32TP Mark III4
727LTCP4 &
M132R1204
728LTCP4 &
M132R277C4
731LTCP4 &
M232SR120C4
732LTCP4 &
M232SR277C4
---
F025T8 or F032T8 Rapid Start - High Power Factor
48096
MB1x25/32/120RS-LW
120
1
48240
MB1x25/32/120RS-SRNK
120
1
48241
MB1x25/32/277RS-SRNK
277
1
48242
MB2x25/32/120RS-SRNK
120
2
48243
MB2x25/32/277RS-SRNK
277
2
43
74
75
--8G4126W18
8G4136W18
T12 RAPID START
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
F30T12 Rapid Start - High Power Factor
48409
48410
48397
MB2x30/120RS-SRNK
MB2x30/277RS-SRNK
MB2x30/40/120RS
120
277
120
2
2
2
F30T12, F25T12/SS
F30T12, F25T12/SS
F30T12, F25T12/SS, F40T10,
FC12T9 & FC16T9
80, 70
80, 70
66, 57
R2SP30TP Mark III
V2SP30TP Mark III
RC2SP40TP
573LTCP
588LTCP
W589DTCP
8G3971W
8G3972W
---
F40T12, F34T12†, FB34T12/U,
FB40T12/U, F40T10, F30T12
F40T12, F34T12†, FB34T12/U,
FB40T12/U, F40T10, F30T12
F40T12, F34T12, FB34T12/U,
FB40T12/U, F40T10
F40T12, F34T12, FB34T12/U,
FB40T12/U, F40T10
50, 44
R140TP Mark III
412LSLHTCP
8G1074W
50, 44
V140TP Mark III
458LSLHTCP
8G1084W
87, 73
R2S40TP Mark III
446LSLHTCP
8G1024W
89, 77
V2S40TP Mark III
443LSLHTCP
8G1034W
31
RL140TP
413CTCP
8G1075
136, 117
RS110TP
481LHTCP
8G3900W
138, 122
VS110TP
479LHTCP
8G4200WF
243, 211
R2S110TP Mark III
480SLHTCP
8G1144W
242, 218
V2S110TP Mark III
487SLHTCP
8G1154W
154
RS110TP
490XLHTCP
---
182
ASB-0412-12-BL-TP
USB-0412-12
6G3901WF
282
ASB-0620-24-BL-TP
USB-0816-14
6G3814WF
290
ASB-1224-24-BL-TP
USB-1024-14
6G3959WF
471
ASB-2040-24-BL-TP
USB-1632-24
6G3782WF
466
ASB-1240-46-BL-TP
USB-2036-46
6G3787AWF
588
ASB-2448-46-BL-TP
USB-2048-46
6G3942AW
F40T12 Rapid Start - High Power Factor
48011 L MB1x40/120RS-SRNK
120
1
48120 L MB1x40/277RS-SRNK
277
1
48001 L MB2x40/120RS-SRNK
120
2
48121 L MB2x40/277RS-SRNK
277
2
F40T12 Rapid Start - Normal Power Factor - For Residential Use Only
48210
MB1x40/120RES-SRNK
120
1
F40T12, F30T12, FC12T9, FC16T9
F96T12/HO, F96T12/HO/SS(95W), F84T12/HO,
F72T12/HO, F64T12/HO, F60T12/HO,
F48T12/HO, F42T12/HO, F36T12/HO,
F30T12/HO, F24T12/HO, F18T12/HO
F96T12/HO, F96T12/HO/SS(95W), F84T12/HO,
F72T12/HO, F64T12/HO, F60T12/HO,
F48T12/HO, F42T12/HO, F36T12/HO,
F30T12/HO, F24T12/HO, F18T12/HO
F96T12/HO, F96T12/HO/SS(95W), F84T12/HO,
F72T12/HO, F64T12/HO, F60T12/HO,
F48T12/HO, F42T12/HO, F36T12/HO,
F30T12/HO, F24T12/HO, F18T12/HO
F96T12/HO, F96T12/HO/SS(95W), F84T12/HO,
F72T12/HO, F64T12/HO, F60T12/HO,
F48T12/HO, F42T12/HO, F36T12/HO,
F30T12/HO, F24T12/HO, F18T12/HO
F48T12/HO, F96T12/HO, F72T12/HO,
F60T12/HO, F84T12/HO, F36T12/HO,
F24T12/HO
T12/HO RAPID START
F96T12/HO Rapid Start - High Power Factor
48127
MB1x96/HO/120RS-SRNK
120
1
48128
MB1x96/HO/277RS-SRNK
277
1
48025 L MB2x96/HO/120RS-SRNK
120
2
48027 L MB2x96/HO/277RS-SRNK
277
2
48151
120
1 or 2
MB1/2x48/96/HO/120RS-SRNK/IN
T12/HO SIGN BALLASTS
T12/HO Rapid Start
48225
MSB-12-0412-TP
120
1-2
48226
MSB-24-0620-TP
120
2-4
48227
MSB-24-1224-TP
120
2-4
48228
MSB-24-2040-TP
120
2-4
48229
MSB-46-1240-TP
120
4-6
48232
MSB-46-2448-TP
120
4-6
198
Any T12/HO, (800mA) lamp within quantity of
lamp and lamp length requirements.3
Any T12/HO, (800mA) lamp within quantity of
lamp and lamp length requirements.3
Any T12/HO, (800mA) lamp within quantity of
lamp and lamp length requirements.3
Any T12/HO, (800mA) lamp within quantity of
lamp and lamp length requirements. See wiring
diagram for further wiring instructions.3
Any T12/HO, (800mA) lamp within quantity of
lamp and lamp length requirements. See wiring
diagram for further wiring instructions.3
Any T12/HO, (800mA) lamp within quantity of
lamp and lamp length requirements. See wiring
diagram for further wiring instructions.3
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 199
Magnetic Fluorescent Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
No. of
Lamps
Lamp
Types
Input
Power
(Watts)1
Advance
Catalog # 2
Universal Lighting
Technologies*
Valmont
Catalog # 2
Catalog # 2
J-BOX COVER
For Sign & F-Can Ballasts
48275
JBox Cover
PC-875W
---
---
218, 200
RC2S102TP4
951STCP
8G3927WF
212, 192
VC2S102TP4
957STCP
8G3990WF
452, 408
RS2S200TP
930KTCP
8G1201W
423, 380
VS2S200TP
937KTCP
8G1211W
29
RLQS122TPW
547RSWSTCP
8G1091G11
31
31, 32
RLCS140TPW
RL140TP
445RSWSTCP
---
8G1085G11
---
71
---
---
---
T12/VHO RAPID START
F96T12/VHO Rapid Start - High Power Factor
48129
MB1x96/VHO/120RS-SRNK
120
1
48130
MB1x96/VHO/277RS-SRNK
277
1
48131
MB2x96/VHO/120RS-SRNK
120
2
48132
MB2x96/VHO/277RS-SRNK
277
2
F96T12/VHO, F96T12/VHO/SS(195W),
F72T12/VHO, F60T12/VHO, F48T12/VHO
F96T12/VHO, F96T12/VHO/SS(195W),
F72T12/VHO, F60T12/VHO, F48T12/VHO
F96T12/VHO, F96T12/VHO/SS(195W),
F72T12/VHO, F60T12/VHO, F48T12/VHO
F96T12/VHO, F96T12/VHO/SS(195W),
F72T12/VHO, F60T12/VHO, F48T12/VHO
T9 CIRCLINE RAPID START
FC8T9 Circline Rapid Start - Normal Power Factor
48230
MB1x22/120CIRC-SRNK
120
1
FC8T9
FC12T9 or FC16T9 Circline Rapid Start - Normal Power Factor
48231
48210
MB1x32/120CIRC-SRNK
MB1x40/120RES-SRNK
120
120
1
1
FC12T9, FC16T9
FC12T9, FC16T9, F40T12, F30T12
FC12T9 & FC16T9 Circline Rapid Start - High Power Factor
48397
MB2x30/40/120RS
120
2
FC12T9 & FC16T9, F40T10,
F30T12, F25T12/SS
2
2
F48T12, F48T12/SS(32W)
F48T12, F48T12/SS(32W)
87, 78
88, 81
SM2E40STP
VSM2E40STP
213TCP
532BRTCP
8G1600W
8G1710W
F96T12, F96T12/SS(60W), F84T12,
F72T12, F64T12, F60T12
F96T12, F96T12/SS(60W), F84T12,
F72T12, F64T12, F60T12
F96T12, F96T12/SS(60W), F84T12,
F72T12, F64T12, F60T12
F96T12, F96T12/SS(60W), F84T12,
F72T12, F64T12, F60T12
101, 87
RSM175STP
822BRTCP
8G1762W
101, 86
VSM175STP
828BRTCP
8G1764W
160, 135
R2E75STP Mark III
806SLHTCP
8G1004W
162, 140
V2E75STP Mark III
827SLHTCP
8G1014W
T12 INSTANT START SLIMLINE
F48T12 Instant Start - High Power Factor
48122
48123
MB2x48/120IS-SRNK
MB2x48/277IS-SRNK
120
277
F96T12 Instant Start - High Power Factor
48124
MB1x96/120IS-SRNK
120
1
48125
MB1x96/277IS-SRNK
277
1
48018 L MB2x96/120IS-SRNK
120
2
48126 L MB2x96/277IS-SRNK
277
2
T5, T8 and T12 PREHEAT START
F8T5 Preheat Start - Normal Power Factor
48475
MB1x8/120PH/TP/S-SRNK
120
1
F8T5, F4T5, F6T5
10
LSX113TP4
---
89G489
1
1
F20T12, F14T8, F14T12, F15T8, F15T12
F20T12, F14T8, F14T12, F15T8, F15T12
22
22
LC1420CTP
LC1420C
200H2P
200H2
--89G457
1
F15T12, F14T8, F14T12, F15T8, F20T12
33
RLQ120TP
546BTCP
8G3560
2
F20T12, F14T8, F14T12, F15T8, F15T12
41
RL2SP20TP
447LRTCP
8G3912
F20T12 Preheat Start - Normal Power Factor
48201
48202
MB1x20/120PH/TP
MB1x20/120PH
120
120
T8 and T12 TRIGGER START
F15T12 Trigger Start - Normal Power Factor
48200
MB1x15/120PH/TP-SRNK
120
F20T12 Trigger Start - Normal Power Factor
48203
MB2x20/120PH/TP-SRNK
120
* Formerly MagneTek Lighting
L For Replacement Use Only
† Operating only 1 Energy Saver lamp on this ballast may effect the operation and life of the lamp. Consult individual lamp manufacturer for lamp specifications
1: Input Power (Watts) for primary lamp type and SUPERSAVER® equivalent, (where applicable). Primary lamp type and SUPERSAVER® equivalent in bold print.
2: This data is intended as an aid for identifying comparable products for the lamp types listed as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness
of the content. Case sizes, wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA Magnetic Ballast catalog for
verification of product specifications appropriate for the application.
3: Refer to SYLVANIA Sign Ballast Specification Sheet for detailed lamp configuration. Maximum Input Power (Watts) are listed.
4: Nearest Equivalent - Performance specifications may vary, please refer to manufacturer’s specifications.
More complete product information is available in the SYLVANIA Magnetic Ballast Catalog or at www.sylvania.com
SPECIFICATIONS:
Information is subject to change at anytime without prior notice.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
199
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 200
Magnetic HID Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Circuit
Type
Input
Power
(Watts)
Advance
Catalog # 8
Universal Lighting
Technologies*
Catalog # 8
Venture
Lighting
Catalog # 8
Howard
Industries
Catalog # 8,9
M175ML5AC3M &
M175ML5AC3M-500K
M175MLTAC3M &
M175MLTAC3M-500K
---
---
M017581C212
V90D6111K
M017571C211
---
---
M17548TAC3M &
M17548TAC3M-500K
---
---
---
---
---
M250ML5AC4M &
M250ML5AC4M-500K
M250MLTAC4M &
M250MLTAC4M-500K
---
---
M025081C211
V90D6212K
M025071C211
---
M025011C211
M25048TAC4M &
M25048TAC4M-500K
M250MLTAC3M &
M250MLTAC3M-500K
---
V90Y6212TK
M025029C211
V90D6211K
M025071C212
V90Y6211K
M025011C212
M400ML5AC4M &
M400ML5AC4M-500K
M400MLTAC4M &
M400MLTAC4M-500K
M400480AC4M
---
M040081C211
V90D6413K
M040071C211
---
M040011C211
M40048TAC4M &
M40048TAC4M-500K
---
V90Y6413TK
M040029C211
---
---
METALARC® METAL HALIDE CORE & COIL BALLAST KITS
175W Metal Halide Lamp - ANSI Code M57
47243
M175/SUPER5-KIT
M175/480-KIT
120/208/
240/277/480
120/208/
240/277
480
47735
M175/MULTI-KIT
47035
CWA
210
---
CWA
210
CWA
210
480/120TAP
CWA
210
71A5590 &
71A5570-001D
71A5540 &
71A5540-001D
71A5540T
47253
M175/480/120T-KIT
47254
M175/120/277-KIT
120/277
CWA
210
71A5580
CWA
290
71A5750 &
71A5750-001D
71A5790 &
71A5770-001D
71A5740 &
71A5740-001D
71A5740T
250W Metal Halide Lamp - ANSI Code M58
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
47265
M250/SUPER5-KIT
CWA
290
M250/480-KIT
120/208/
240/277/480
120/208/
240/277
480
47737
M250/MULTI-KIT
47611
CWA
290
47268
M250/480/120T-KIT
480/120TAP
CWA
290
47049
M250/MULTI 3X4-KIT
CWA
294
47050
M250/480-3X4-KIT
120/208/
240/277
480
CWA
294
71A5791 &
71A5771-001D
71A5741 &
71A5741-001D
400W Metal Halide Lamp or 360W Metal Halide Lamp10 - ANSI Code M59
47338
M400/SUPER5-KIT
CWA
458
CWA
458
M400/480-KIT
120/208/
240/277/480
120/208/
240/277
480
CWA
458
47394
M400/480/120T-KIT
480/120TAP
CWA
458
71A6051 &
71A6051-001D
71A6091 &
71A6071-001D
71A6041 &
71A6041-001D
71A6041T
47739
M400/MULTI-KIT
47065
47075
M2x400/120/240-KIT
120/240
CWA
880
---
CWA
1080
71A65526 &
71A6552-0016
71A65926 &
71A6572-0016
71A65426 &
71A6542-0016
71A6542T6
M1000ML5AC5M &
M1000ML5AC5M-500K
M1000MLTAC5M &
M1000MLTAC5M-500K
M1000480AC5M &
M1000480AC5M-500K
M100048TAC5M &
M100048TAC5M-500K
V90AM6514K
---
V90D6514K
M0100071C212
---
M0100011C212
V90Y6514TK
---
71A67926 &
71A6772-0016
71A67426 &
71A6742-0016
---
M1500MLTAC5M &
M1500MLTAC5M-500K
M1500480AC5M &
M1500480AC5M-500K
M150048TAC5M &
M150048TAC5M-500K
V90D6612K
M0150071C212
---
M0150011C212
V90Y6612TK
---
1000W Metal Halide Lamp - ANSI Code M47
47427
M1000/SUPER5-KIT
CWA
1080
M1000/480-KIT
120/208/
240/277/480
120/208/
240/277
480
47744
M1000/MULTI-KIT
47655
CWA
1080
47432
M1000/480/120T-KIT
480/120TAP
CWA
1080
1500W Metal Halide Lamp - ANSI Code M48
46808
M1500/MULTI-KIT
47095
M1500/480-KIT
47434
M1500/480/120T-KIT
120/208/
240/277
480
CWA
1605
CWA
1605
480/120TAP
CWA
1605
METALARC METAL HALIDE PULSE START CORE & COIL BALLAST KITS
35W Metal Halide Pulse Start Lamp - ANSI Code M130
47001
M35/MULTI-HQ/CI-KIT
47203
M35/120/277-KIT
120/208/
240/277
120/277
CWA
58
---
---
---
---
HX-HPF
54
71A5081
---
---
---
HX-HPF
67
---
V90D5731K
---
HX-HPF
67
71A5181 &
71A5181-001D
M50MLTLC3M &
M50MLTLC3M-500K
---
V90H5731K
---
HX-HPF
95
---
95
M70MLTLC3M &
M70MLTLC3M-500K
---
V90D5832K
HX-HPF
71A5292 &
71A5292-001D
71A5282
V90H5832K
---
95
---
---
V90D5810K
---
HX-HPF
130
M010071C511
130
M100MLTLC3M &
M100MLTLC3M-500K
---
V90D5932K
HX-HPF
71A5390 &
71A5390-001D
71A5380
V90H5932K
---
50W Metal Halide Pulse Start Lamp - ANSI Code M110
47007
M50/MULTI-KIT
47204
M50/120/277-KIT
120/208/
240/277
120/277
70W Metal Halide Pulse Start Lamp - ANSI Code M98
47013
M70/MULTI-KIT
47217
M70/120/277-KIT
120/208/
240/277
120/277
70W Metal Halide Pulse Start Lamp - ANSI Code M98 or M139 or M85
47645
M70/MULTI-HQ/CI-KIT
120/208/
240/277
CWA
100W Metal Halide Pulse Start Lamp - ANSI Code M90
47019
M100/MULTI-KIT
47219
M100/120/277-KIT
200
120/208/
240/277
120/277
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 201
Magnetic HID Ballasts
Input
Item
OSRAM SYLVANIA
Voltage
Circuit
Number
Description
(VAC)
Type
150W Metal Halide Pulse Start Lamp - ANSI Code M102
47682
M150/MULTI-PS-KIT
47228
M150/120/277-PS-KIT
120/208/
240/277
120/277
Input
Power
(Watts)
HX-HPF
185
HX-HPF
Advance
Catalog # 8
Universal Lighting
Technologies*
Catalog # 8
Venture
Lighting
Catalog # 8
Howard
Industries
Catalog # 8,9
M150MLTLC3M &
M150MLTLC3M-500K
---
V90D7130K
---
185
71A5492 &
71A5492-001D
71A5482
---
---
189
---
---
V90D7110K
---
185
71A5490
M150MLTLC3D &
M150MLTLC3D-500K
---
---
CWA
208
---
208
P175MLTAC3M &
P175MLTAC3M-500K
---
V90D7210K
CWA
71A5593 &
71A5593-001D
---
---
---
P200MLTAC3M &
P200MLTAC3M-500K
--P20048TAC3M &
P20048TAC3M-500K
V90D7310K
M020071C611
--V90Y7310TK
M020011C611
M020029C611
150W Metal Halide Pulse Start Lamp - ANSI Code M102 or M142
47640
M150/MULTI-PS-CWA-KIT
120/208/
240/277
CWA
150W Metal Halide Pulse Start Lamp - ANSI Code M81
47229
M150/MULTI-KIT
120/208/
240/277
HX-HPF
175W Metal Halide Pulse Start Lamp - ANSI Code M137 or M152
47686
M175/MULTI-PS-KIT
46801
M175/480-PS-KIT
120/208/
240/277
480
200W Metal Halide Pulse Start Lamp - ANSI Code M136
47690
M200/MULTI-PS-KIT
46802
47259
M200/480-PS-KIT
M200/480/120T-PS-KIT
120/208/
240/277
480
480/120TAP
CWA
232
CWA
CWA
232
232
71A5692 &
71A5692-001D
--71A5642T
HX-HPF
290
71A5880
---
---
---
CWA
288
---
P250ML5AC4M
---
---
CWA
288
M025071C611
288
288
P250MLTAC4M &
P250MLTAC4M-500K
--P25048TAC4M &
P25048TAC4M-500K
V90D8410K
CWA
CWA
71A5792 &
71A5792-001D
--71A5742T
-----
-----
71A5892 &
71A5892-001D
--71A5842T &
71A5842-001DT
P320MLTAC4M &
P320MLTAC4M-500K
--P32048TAC4M &
P32048TAC4M-500K
V90D7411K
M032071C611
--V90Y7411TK
-----
P350MLTAC4M &
P350MLTAC4M-500K
--P35048TAC4M &
P35048TAC4M-500K
V90D7512K
M035071C611
--V90Y7512TK
-----
250W HQI Metal Halide Lamp - ANSI Code M80
47273
M250/120/277-KIT
120/277
250W Metal Halide Pulse Start Lamp - ANSI Code M138 or M153
47282
M250/SUPER5-PS-KIT
47112
M250/MULTI-PS-KIT
47106
47283
M250/480-PS-KIT
M250/480/120T-PS-KIT
120/208/
240/277/480
120/208/
240/277
480
480/120TAP
320W Metal Halide Pulse Start Lamp - ANSI Code M132 or M154
47676
M320/MULTI-PS-KIT
46803
47303
M320/480-PS-KIT
M320/480/120T-PS-KIT
120/208/
240/277
480
480/120TAP
CWA
368
CWA
CWA
368
368
350W Metal Halide Pulse Start Lamp - ANSI Code M131
47695
M350/MULTI-PS-KIT
47697
47337
M350/480-PS-KIT
M350/480/120T-PS-KIT
120/208/
240/277
480
480/120TAP
CWA
400
CWA
CWA
400
400
71A5993 &
71A5993-001D
--71A5943T
CWA
452
---
P400ML5AC4M
---
---
CWA
452
M040071C611
452
452
P400MLTAC4M &
P400MLTAC4M-500K
--P40048TAC4M &
P40048TAC4M-500K
V90D7612K
CWA
CWA
71A6092 &
71A6092-001D
--71A6042T
--V90Y7612TK
M040011C611
M040029C611
CWA
508
71A6393
V90D8512K
---
CWA
CWA
505
505
--71A6343T
P450MLTAC4M &
P450MLTAC4M-500K
--P45048TAC4M &
P45048TAC4M-500K
--V90Y8511TK
-----
400W Metal Halide Pulse Start Lamp - ANSI Code M155 or M135
47400
M400/SUPER5-PS-KIT
47132
M400/MULTI-PS-KIT
47138
47403
M400/480-PS-KIT
M400/480/120T-PS-KIT
120/208/
240/277/480
120/208/
240/277
480
480/120TAP
450W Metal Halide Pulse Start Lamp - ANSI Code M144
47405
M450/MULTI-PS-KIT
46804
47408
M450/480-PS-KIT
M450/480/120T-PS-KIT
120/208/
240/277
480
480/120TAP
750W Metal Halide Pulse Start Lamp - ANSI Code M149
47717
M750/MULTI-PS-KIT
47409
M750/120/277/347/480-PS-KIT
47718
M750/480-PS-KIT
120/208/
240/277
120/277/
347/480
480
CWA
818
71A64E26,7
V90D7910K
---
71A64F2T6,7
P750MLTAC5M &
P750MLTAC5M-500K
---
CWA
818
V90J7910K7
---
CWA
818
---
---
---
---
120/277/347/480
Reg. Lag
1150
---
---
---
---
V90D7810K
---
V90J7810K7
---
-----
---
---
1000W HQI® Metal Halide Lamp
47089
M1000/120/277/347/480-HQI-RL
1000W Metal Halide Pulse Start Lamp - ANSI Code M141
47416
M1000/MULTI-PS-KIT
47417
46805
M1000/120/277/347/480-PS-KIT
M1000/480-PS-KIT
120/208/
240/277
120/277/347/480
480
CWA
1080
71A65936
CWA
CWA
1080
1080
71A65F3T6,7
---
P1000MLTAC5M &
P1000MLTAC5M-500K
-----
277/347/480
Reg. Lag
2200
---
---
2000W HQI® Metal Halide Lamp
47090
M2000/277/347/480-HQI-RL
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
201
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 202
Magnetic HID Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Circuit
Type
Input
Power
(Watts)
Advance
Catalog # 8
Universal Lighting
Technologies*
Catalog # 8
Venture
Lighting
Catalog # 8
Howard
Industries
Catalog # 8,9
LUMALUX® HIGH PRESSURE SODIUM CORE & COIL REACTOR BALLASTS
35W High Pressure Sodium Lamp - ANSI Code S76
47269
47537
LU35/120R
LU35/120R-INT5
120
120
R-NPF
R-NPF
45
45
71A7707
71A7707B
1233-251U
---
-----
-----
R-NPF
R-NPF
60
60
71A7807
71A7807B
1233-35U
---
-----
-----
R-NPF
R-NPF
81
81
71A7907
71A7907B
1233-142U
---
-----
-----
120
120
71A8007
71A8007B
1233-10U
---
-----
-----
170
170
71A8107
71A8107B
1233-154U
---
-----
-----
50W High Pressure Sodium Lamp - ANSI Code S68
47274
47548
LU50/120R
LU50/120R-INT5
120
120
70W High Pressure Sodium Lamp - ANSI Code S62
47284
47558
LU70/120R
LU70/120R-INT5
120
120
100W High Pressure Sodium Lamp - ANSI Code S54
47304
47585
LU100/120R
LU100/120R-INT5
120
120
R-NPF
R-NPF
150W High Pressure Sodium Lamp - ANSI Code S55
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
47319
47616
LU150/120R
LU150/120R-INT5
120
120
R-NPF
R-NPF
LUMALUX HIGH PRESSURE SODIUM CORE & COIL BALLAST KITS
35W High Pressure Sodium Lamp - ANSI Code S76
47271
LU35/120/240-KIT
120/240
HX-HPF
47
---
---
---
---
66
71A7801 &
71A7801-001D
---
V90H1132K
S005023C511
HX-HPF
91
S007071C511
91
91
S70MLTLC3M &
S70MLTLC3M-500K
-----
V90D1233K
HX-HPF
HX-HPF
71A7991 &
71A7971-001D
71A7941
71A7901
-----
-----
71A8091 &
71A8071-001D
71A8041 &
71A8041-001D
71A8001
S100MLTLC3M &
S100MLTLC3M-500K
---
V90D1333K
S010071C511
---
---
---
---
---
S150MLTLC3M &
S150MLTLC3M-500K
---
V90D1435K
S015071C511
---
---
S15048TLC3M &
S15048TLC3M-500K
-----
---
---
-----
-----
50W High Pressure Sodium Lamp - ANSI Code S68
47549
LU50/120/277-KIT
120/277
HX-HPF
70W High Pressure Sodium Lamp - ANSI Code S62
47301
LU70/MULTI-KIT
47579
47571
LU70/480-KIT
LU70/120/277-KIT
120/208/
240/277
480
120/277
100W High Pressure Sodium Lamp - ANSI Code S54
47316
LU100/MULTI-KIT
HX-HPF
128
LU100/480-KIT
120/208/
240/277
480
47593
HX-HPF
128
47592
LU100/120/277-KIT
120/277
HX-HPF
128
150W High Pressure Sodium Lamp - ANSI Code S55
47335
LU150/MULTI-KIT
120/208/
240/277
480
HX-HPF
188
HX-HPF
188
LU150/480/120T-KIT
480/120TAP
HX-HPF
188
71A8192 &
71A8172-001D
71A8142 &
71A8142-001D
71A8142T
47619
LU150/480-KIT
47621
47617
47623
LU150/120/277-KIT
LU150/480-CWA-KIT
120/277
480
HX-HPF
CWA
188
185
71A8102
71A8148
CWA
230
---
230
S200MLTAC4M &
S200MLTAC4M-500K
---
V90D1610K
CWA
71A8990 &
71A8970-001D
71A8940 &
71A8940-001D
---
---
S250ML5AC4M &
S250ML5AC4M-500K
S250MLTAC4M &
S250MLTAC4M-500K
---
---
S025081C211
V90D1711K
S025071C211
---
---
---
---
---
---
200W High Pressure Sodium Lamp - ANSI Code S66
47628
LU200/MULTI-KIT
47631
LU200/480-KIT
120/208/
240/277
480
250W High Pressure Sodium Lamp - ANSI Code S50
47634
LU250/SUPER5-KIT
LU250/480-KIT
120/208/
240/277/480
120/208/
240/277
480
47357
LU250/MULTI-KIT
47358
47637
LU250/480/120T-KIT
47642
LU250/120/277-KIT
202
CWA
295
CWA
295
CWA
295
480/120TAP
CWA
295
71A8251 &
71A8251-001D
71A8291 &
71A8271-001D
71A8241 &
71A8241-001D
71A8241T
120/277
CWA
295
71A8281
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
S25048TAC4M &
S25048TAC4M-500K
---
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 203
Magnetic HID Ballasts
Input
Item
OSRAM SYLVANIA
Voltage
Circuit
Number
Description
(VAC)
Type
310W High Pressure Sodium Lamp - ANSI Code S67
47643
LU310/MULTI-KIT
47644
LU310/480-KIT
120/208/
240/277
480
Input
Power
(Watts)
CWA
355
CWA
355
Advance
Catalog # 8
71A8391 &
71A8371-001D
71A8341
Universal Lighting
Technologies*
Catalog # 8
Venture
Lighting
Catalog # 8
Howard
Industries
Catalog # 8,9
---
V90D1810K
---
---
---
---
S400ML5AC4M &
S400ML5AC4M-500K
S400MLTAC4M &
S400MLTAC4M-500K
---
---
---
V90D1911K &
V90D1912K
---
S040071C211
S040011C211
---
---
---
---
400W High Pressure Sodium Lamp - ANSI Code S51
47647
LU400/SUPER5-KIT
LU400/480-KIT
120/208/
240/277/480
120/208/
240/277
480
47364
LU400/MULTI-KIT
47376
CWA
464
CWA
464
CWA
464
480/120TAP
CWA
464
71A8453 &
71A8453-001D
71A8493 &
71A8473-001D
71A8443 &
71A8443-001D
71A8443T
47657
LU400/480/120T-KIT
120/277
CWA
464
---
S40048TAC4M &
S40048TAC4M-500K
---
47656
LU400/120/277-KIT
CWA
830
71A86E56,7
---
---
---
CWA
830
---
---
---
---
CWA
1100
---
1100
V90D2311K
S100071C211
CWA
1100
S1000ML5AC5M &
S1000ML5AC5M-500K
S1000MLTAC5M &
S1000MLTAC5M-500K
---
---
CWA
71A87536 &
71A8753-0016
71A87936 &
71A8773-0016
71A87436 &
71A8743-0016
---
S100011C211
750W High Pressure Sodium Lamp - ANSI Code S111
47712
LU750/MULTI-KIT
47658
LU750/480-KIT
120/208/
240/277
480
1000W High Pressure Sodium Lamp - ANSI Code S52
47659
LU1000/SUPER5-KIT
47389
LU1000/MULTI-KIT
47391
LU1000/480-KIT
120/208/
240/277/480
120/208/
240/277
480
METALARC® METAL HALIDE F-CAN HID BALLASTS
175W Metal Halide Lamp - ANSI Code M57
47743
M175/120/277/F-CAN
120/277
CWA
205
72C5581-NP &
72C5581-NP-001
1110-245SC-TC
---
---
CWA
295
72C5782-NP &
72C5782-NP-001
1110-246C-TC4
---
---
72C6082-NP &
72C6082-NP-001
1110-247SC-TC
---
---
250W Metal Halide Lamp - ANSI Code M58
47751
M250/120/277/F-CAN
120/277
400W Metal Halide Lamp or 360W Metal Halide Lamp10 - ANSI Code M59
47759
M400/120/277/F-CAN
120/277
CWA
460
METALARC METAL HALIDE PULSE START F-CAN HID BALLASTS
35W Metal Halide Pulse Start Lamp - ANSI Code M130
47680
M35/120/277/F-CAN
120/277
HX-HPF
54
72C5081-NP
---
---
---
67
72C5181-NP &
72C5181-NP-001
11210-236C-TC
---
---
95
72C5281-NP
---
---
---
94
72C5282-NP &
72C5282-NP-001
11210-506C-TC
---
---
125
72C5381-NP &
72C5381-NP-001
11210-239C-TC
---
---
185
---
---
---
---
210
72C5582-NP &
72C5582-NP-001
---
---
---
240
---
---
---
---
295
72C5783-NP &
72C5783-NP-001
---
---
---
375
72C5882-NP &
72C5882-NP-001
P320277AFXM
---
---
465
72C6182-NP &
72C6182-NP-001
---
---
---
50W Metal Halide Pulse Start Lamp - ANSI Code M110
47195
M50/120/277/F-CAN
120/277
HX-HPF
70W Metal Halide Pulse Start Lamp - ANSI Code M139
47693
M70/120/277/F-CAN
120/277
HX-HPF
70W Metal Halide Pulse Start Lamp - ANSI Code M98 or M143
47694
M70/120/277/F-CAN
120/277
HX-HPF
100W Metal Halide Pulse Start Lamp - ANSI Code M90
47734
M100/120/277/F-CAN
120/277
HX-HPF
150W Metal Halide Pulse Start Lamp - ANSI Code M102 or M142
47738
M150-PS/120/277/F-CAN
120/277
CWA
175W Metal Halide Pulse Start Lamp - ANSI Code M137 or M152
47741
M175-PS/120/277/F-CAN
120/277
CWA
200W Metal Halide Pulse Start Lamp - ANSI Code M136
47747
M200-PS/120/277/F-CAN
120/277
CWA
250W Metal Halide Pulse Start Lamp - ANSI Code M138 or M153
47749
M250-PS/120/277/F-CAN
120/277
CWA
320W Metal Halide Pulse Start Lamp - ANSI Code M132 or M154
47753
M320-PS/120/277/F-CAN
120/277
CWA
400W Metal Halide Pulse Start Lamp - ANSI Code M155 or M135
47757
M400-PS/120/277/F-CAN
120/277
CWA
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
203
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 204
Magnetic HID Ballasts
Item
Number
OSRAM SYLVANIA
Description
Input
Voltage
(VAC)
Circuit
Type
Input
Power
(Watts)
Advance
Catalog # 8
Universal Lighting
Technologies*
Catalog # 8
Venture
Lighting
Catalog # 8
Howard
Industries
Catalog # 8,9
LUMALUX® HIGH PRESSURE SODIUM F-CAN HID BALLASTS
35W High Pressure Sodium Lamp - ANSI Code S76
47761
LU35/120/277/F-CAN
120/277
HX-HPF
47
---
12210-261C-TC
---
---
65
72C7884-NP &
72C7884-NP-001
12210-236C-TC
---
---
90
72C7984-NP &
72C7984-NP-001
12210-237C-TC
---
---
125
72C8084-NP &
72C8084-NP-001
12210-239C-TC
---
---
185
72C885-NP
12210-241C-TC
---
---
298
---
1220-246C-TC
---
---
50W High Pressure Sodium Lamp - ANSI Code S68
47762
LU50/120/277/F-CAN
120/277
HX-HPF
70W High Pressure Sodium Lamp - ANSI Code S62
47763
LU70/120/277/F-CAN
120/277
HX-HPF
100W High Pressure Sodium Lamp - ANSI Code S54
47764
LU100/120/277/F-CAN
120/277
HX-HPF
150W High Pressure Sodium Lamp - ANSI Code S55
47765
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
LU150/120/277/F-CAN
120/277
HX-HPF
250W High Pressure Sodium Lamp - ANSI Code S50
47777
LU250/120/277/F-CAN
120/277
CWA
METALARC® METAL HALIDE INDOOR ENCLOSED HID BALLASTS
175W Metal Halide Lamp - ANSI Code M57
47153
M175/MULTI-I/D
120/208/
240/277
CWA
210
78E5590-001
---
---
---
CWA
290
78E5790-001
---
---
---
250W Metal Halide Lamp - ANSI Code M58
47158
M250/MULTI-I/D
120/208/
240/277
400W Metal Halide Lamp or 360W Metal Halide Lamp10 - ANSI Code M59
47172
M400/MULTI-I/D
120/208/
240/277
CWA
458
78E6091-001
---
---
---
CWA
1080
78E6592-001
---
---
---
1000W Metal Halide Lamp - ANSI Code M47
47207
M1000/MULTI-I/D
120/208/
240/277
EPAct 2005 has mandated that no Mercury Vapor Ballasts be manufactured in the US effective January 1, 2008.
MERCURY CORE & COIL BALLAST KITS
50W Mercury Lamp - ANSI Code H46
46518
H50/MULTI-KIT
120/208/
240/277
CWA
68
---
---
---
---
CWA
92
71A20807
---
---
---
CWA
120
---
120
120
H100MLTAC3M &
H100MLTAC3M-500K
-----
---
CWA
CWA
71A2591 &
71A2571-001D
--71A25017
-----
-----
CWA
205
---
205
H175MLTAC3M &
H175MLTAC3M-500K
---
---
CWA
71A3092 &
71A3072-001D
71A3042 &
71A3042 -001D
---
---
71A3592 &
71A3572-001D
71A3542 &
71A3542-001D
71A3542T
H250MLTAC3M &
H250MLTAC3M-500K
---
---
---
---
---
H25048TAC3M &
H25048TAC3M-500K
---
---
H400MLTAC4M &
H400MLTAC4M-500K
---
---
---
---
---
---
---
-----
-----
---
---
---
---
75W Mercury Lamp - ANSI Code H43
46519
H75/MULTI-KIT
120/208/
240/277
100W Mercury Lamp - ANSI Code H38 or H44
46522
H100/MULTI-KIT
47472
47471
H100/277-KIT
H100/DUAL-KIT
120/208/
240/277
277
120/240
175W Mercury Lamp - ANSI Code H39
47489
H175/MULTI-KIT
47490
H175/480-KIT
120/208/
240/277
480
250W Mercury Lamp - ANSI Code H37
47499
H250/MULTI-KIT
47500
H250/480-KIT
46531
H250/480/120T-KIT
120/208/
240/277
480
CWA
285
CWA
285
480/120TAP
CWA
285
400W Mercury Lamp - ANSI Code H33
47509
H400/MULTI-KIT
47510
H400/480-KIT
46533
H400/480/120T-KIT
47517
47518
H2X400/120-KIT
H2X400/277-KIT
120/208/
240/277
480
CWA
454
CWA
454
480/120TAP
CWA
454
71A4091 &
71A4071-001D
71A4041 &
71A4041-001D
71A4041T
120
277
CWA
CWA
880
880
-----
CWA
1080
71A5070-0016
CWA
1080
71A5040-0016
H40048TAC4M &
H40048TAC4M-500K
-----
1000W Mercury Lamp - ANSI Code H36
47524
H1000/MULTI-KIT
47525
H1000/480-KIT
204
120/208/
240/277
480
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
H1000MLTAC5M &
H1000MLTAC5M-500K
---
PLG_graycale_2008_FINAL.qxd:Empty
12/18/07
10:43 AM
Page 205
Magnetic HID Ballasts
Item
Number
Input
Voltage
(VAC)
OSRAM SYLVANIA
Description
Circuit
Type
Input
Power
(Watts)
ANSI
Code
NOTES:
METALARC® METAL HALIDE LAMP & BALLAST KITS
Lamp & Ballast Kits include SYLVANIA METALARC® Metal Halide lamp
64782
64784
64847
64781
64848
M175/U LAMP/SUPER5 BALLAST KIT
M250/U LAMP/SUPER5 BALLAST KIT
MS360/SS LAMP/SUPER5 BALLAST KIT
M400/U LAMP/SUPER5 BALLAST KIT
M1000/U LAMP/SUPER5 BALLAST KIT
120/208/240/277/480
120/208/240/277/480
120/208/240/277/480
120/208/240/277/480
120/208/240/277/480
CWA
CWA
CWA
CWA
CWA
210
290
415
458
1080
M57/E
M58/E
M59/S
M59/S
M47/S
LUMALUX® HIGH PRESSURE SODIUM LAMP & BALLAST KITS
Lamp & Ballast Kits include SYLVANIA LUMALUX® High Pressure Sodium lamp
67621
67629
67622
67623
67664
LU100/ECO LAMP/MULTI-BALLAST KIT
LU150/55/ECO LAMP/MULTI BALLAST KIT
LU250/ECO LAMP/SUPER5 BALLAST KIT
LU400/ECO LAMP/SUPER5 BALLAST KIT
LU1000 LAMP/SUPER5 BALLAST KIT
120/208/240/277
120/208/240/277
120/208/240/277/480
120/208/240/277/480
120/208/240/277/480
HX-HPF
HX-HPF
CWA
CWA
CWA
128
188
295
464
1100
S54
S55
S50
S51
S52
M
A
G
N
E
T
I
C
B
A
L
L
A
S
T
S
REPLACEMENT IGNITORS FOR SYLVANIA HID BALLASTS 11:
47996
47997
47998
47843
47844
47847
Ignitor/MH/PS/50-150
Ignitor/MH/PS/175-450
Ignitor/MH/PS/750
Ignitor/HPS/50-150
Ignitor/HPS/200-400
Ignitor/HPS/600-750
REPLACEMENT CAPACITORS FOR SYLVANIA HID BALLASTS :
47912
47920
47926
47927
47932
47938
47942
47952
47954
CAP 24Mfd 480VAC
CAP 26Mfd 525VAC
CAP 40Mfd 280VAC
CAP 52Mfd 280VAC
CAP 35Mfd 280VAC
CAP 28Mfd 330VAC
CAP 55Mfd 300VAC
CAP 10Mfd 400VAC
CAP 15Mfd 400VAC
FOOTNOTES:
* Formerly MagneTek Lighting
6: OSRAM SYLVANIA’S HID Ballast is UL Class H Rated
and can be used with the corresponding UL Rated fixtures
only. The ADVANCE Ballast listed is Dual Rated
UL Class H and N.
8: This data is intended as an aid for identifying comparable
products for the lamp types, ANSI Codes and Voltage listed
as a convenience to the user. OSRAM SYLVANIA does not
warrant or guarantee the accuracy or correctness of the
content. Case sizes, wiring diagrams and performance
specifications may vary, please refer to manufacturers
specifications. Please refer to the OSRAM SYLVANIA
Magnetic Ballast catalog for verification of product
specifications appropriate for the application.
7: Ballast Voltage may vary. Always check for required lamp
and voltage.
9: Replacement Kit is indicated by a K at the end of the
catalog number.
4: NEAREST EQUIVALENT - Performance specifications may
vary, please refer to manufacturers specifications.
5: R-INT = Reactor with Integral Ignitor
NOTES:
This data/cross reference is intended as an aid for
identifying comparable products as a convenience to
the user. OSRAM SYLVANIA does not warrant or guarantee
the accuracy or correctness of the content. Cases sizes,
wiring diagrams and performance specifications may
vary, please refer to manufacturers specifications.
10: A 360W Metal Halide lamp ANSI Code M59 operated on
this ballast will result in approximately a 10% reduction in
Input Power (Watts).
11: Only use with the corresponding SYLVANIA HID Ballasts.
Please refer to OSRAM SYLVANIA Magnetic Ballast catalog
for verification of product specifications appropriate for the
application.
HID Core & Coil Ballast Kits include ignitor where applicable,
capacitor where applicable, mounting bracket, hardware and
installation instructions.
More complete product information is available in the
SYLVANIA Magnetic Ballast Catalog or at www.sylvania.com.
SPECIFICATIONS:
Please refer to the OSRAM SYLVANIA Magnetic Ballast
catalog for verification of product specifications appropriate
for the application.
Information is subject to change
at anytime without prior notice.
Please contact 1-800-LIGHTBULB or www.sylvania.com for
additional information.
TRADEMARKS:
SYLVANIA, OCTRON, ICETRON, CURVALUME, METALARC, PENTRON, POWERSENSE, PROSTART, QUICKSENSE, QUICK 60+, LUMALUX, SUPERSAVER,
FIXTURESIDE ASSISTANCE, ECOLOGIC, XP, XPS and
are registered trademarks of OSRAM SYLVANIA Inc. HELIOS
is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC, OPTOTRONIC, DULUX and HQI are registered trademarks of OSRAM GmbH used under license.
All other trademarks are those of their respective owners.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
205
PLG_graycale_2008_FINAL.qxd:Empty
Notes
N
O
T
E
S
206
12/18/07
10:43 AM
Page 206
071_DO_drop.qxd
12/13/07
3:25 PM
Page 207
OSRAM BRAND
DISPLAY/OPTIC LIGHT SOURCES
Lighting to provide solutions in diverse applications such as cinema film projection, effect lighting, stage, studio, TV,
display and projection systems, microlithography, medical/scientific, industrial, and airfield/aircraft.
Display/Optic Lamp Types
HALOGEN
Airfield/Aircraft
Audiovisual
Special Purpose Heat Lamps
Studio, Theatre, TV & Video
aluPAR®
HLX®
HPL
HPR®
OSRAM STUDIOLINE®
XENOPHOT®
D
I
S
P
L
A
Y
O
P
T
I
C
DISCHARGE
HBO®
HCD® 4ArXS
HMI®
HMP®
HSD® 4ArXS
HSR®
HXP®
HTI® SharXS®
LINEX®
P-VIP®
VIP®
XBO®
XERADEX®
IMPORTANT!
DISPLAY/OPTIC WARNINGS
In accordance with ANSI/IESNA Standard RP-27, all Display/Optic Discharge lamps are Risk Group 3 products, and all Display/Optic Incandescent
and Tungsten Halogen lamps are Risk Group 2 products.
Please read and understand the Safety and Warning Instructions for each lamp type before use. Safety and Warning Instructions can be found at the
end of this Display/Optic section.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
207
071_DO_drop.qxd
12/13/07
3:25 PM
Page 208
SOLUTIONS FOR TODAY
UPGRADES FOR POPULAR PROJECTION LAMPS
IF YOU ARE USING:
BHC/DYS/DYV
EHJ 64655 HLX
EHJ 64655 HLX
ELC
ENX
ENX
ENX
EVC 64657 HLX
EVD 64663 HLX
EVD 64663 HLX
EYB
EYB
FCR 64625 HLX
FCS 64640 HLX
FXL or ENX
UPGRADE TO:
BENEFITS
BHC/DYS/DYV-5
EHJ 64655 HLX /7X
EVC 64657 HLX
ELC-HL
ENX-5
ENX-7
FXL
FNT 64656PT HLX
64664 HLX
64665 HLX
EYB-5
EYB-7
EVA 64623 HLX
FDV 64642 HLX
FXL-HL
Double the life at 120V3
Increase life by 14 times2
Increased life by 6 times2
Increased brightness by 150 lumnes4
Double the life at 82V3
Increased life by 2.5 times at 82V3
Increased light
Increased light by 10%1
Increased life by 3 times2 at 36V
Increased life by 6 times2 at 36V
Double the life at 82V3
Increased life by 2.5 times at 82V3
Increased life by 40 times2
Increased life by 6 times2
Increased light1
TECHNICAL DATA
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
34
Ordering Abbreviation
Product
Number Watts
Volts
Rated
Life (hrs)
Fig.
Base
“l”
mm
“a”
mm
“d”
mm
Bulb
Shape
Lumens
64664 HLX
64665 HLX
BHC/DYS/DYV
BHC/DYS/DYV-5
EHJ 64655 HLX
EHJ 64655 HLX/7X
ELC
ELC 64653 HLX
ELC-3/X
ELC-7/X
ELC-HL
ENX
ENX-5
ENX-7
EVA 64623 HLX
EVC 64657 HLX
EVD 64663 HLX
EYB
EYB-5
EYB-7
FCR 64625 HLX
FCS 64640 HLX
FDV 64642 HLX
FNT 64656PT HLX
FXL
FXL-HL
54273
54274
54836
54835
54254
54272
54840
54212
54841
54814
54804
54984
54913
54916
54251
54255
54259
54446
54448
54455
54248
54263
54264
54253
54912
54904
36
36
120
125
24
24
24
24
24
24
24
82
86
87.5
12
24
36
82
85.5
87.5
12
24
24
24
82
82
150
300
75
75
50
700
50
50
300
700
50
75
75
75
2,000
300
50
75
75
75
50
50
300
75
75
40
2
2
3
3
2
2
1
1
1
1
1
1
1
1
2
2
2
4
4
4
2
2
2
2
1
1
G6.35
G6.35
GZ9.5
GZ9.5
G6.35
G6.35
GX5.3
GX5.3
GX5.3
GX5.3
GX5.3
GY5.3
GY5.3
GY5.3
GY6.35
G6.35
G6.35
G5.3
G5.3
G5.3
GY6.35
G6.35
G6.35
G6.35
GY5.3
GY5.3
57
60
64
63.5
55
55
44.8
44.5
44.8
44.8
44.8
45
38.1
38.1
44
55
60
57.2
54
57.2
44
50
50
55
38.1
38.1
36
36
36.5
36.5
33
33
31.7
35
31.7
31.7
31.7
299
299
299
30
33
36
31.8
31.8
31.8
30
32
32
33
299
299
18
18
20
20
13.5
13.5
51
51
51
51
51
51
51
51
11.5
13.5
15
11.2
11.2
11.2
11.5
13.5
13.5
13.5
51
51
T6
T6
T6
T6
T4
T4
T3.5
T3.5
T3.5
T3.5
T3.5
T3.5
T3.5
T3.5
T4
T4
T6
T3.5
T3.5
T3.5
T3.5
T4
T4
T4
T3.5
T3.5
14,500
12,200
17,500
17,500
10,000
8,000
8004
8004
5504
4754
9504
4604
5404
5404
2,800
9,000
16,000
10,000
10,000
10,000
3,600
6,000
5,000
10,000
6404
8504
Figure 1
1
2
3
4
400
400
600
600
250
250
250
250
250
250
250
360
360
360
100
250
400
360
360
360
100
150
150
275
410
410
Figure 2
Figure 4
Lamps designed for increased light output can have a reduced operating life
Lamps designed with a longer operating life can produce fewer lumens
Lamps operated at less than their rated voltage provide a longer life, reduced light output and lower color temperature. A 5% reduction in voltage can double lamp life, decrease luminous flux by 15% and
decrease color temperature by 2%.
Screen Lumens
For more complete product information visit www.sylvania.com
208
Figure 3
|
|
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 209
OSRAM Airfield Lamps
Effective solutions for airfield lighting around the globe.
IRC Reflector
IRC PK30d
PK30d
R7s
GZ(Y)9.5
OSRAM lamps for the airfield lighting industry provide reliable solutions for
complex optical systems. State-of-the-art manufacturing yields high quality
lamps with precision filament alignment that is required in these demanding
applications.
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Why are airfield lighting systems necessary?
• Aviation safety
• Essential visual guidance for approach
• Landing
• Taxiing and take-off
Tungsten halogen technology
Reliability, longevity, and reasonable maintenance costs account for the
success of tungsten halogen lamps as light sources for demanding airfield
lighting applications.
Pre-focus technique
Simple replacement and easy adjustment reduces maintenance costs.
IRC technology (Infrared Reflective Coating)
The innovative IRC technology increases the efficiency of halogen lamps by
reflecting a major part of the generated unwanted IR radiation back to the coil
where it is converted into visible light. The infrared reflective coating at the
outside of the burner acts as an IR mirror but lets nearly 100% of visible
light pass.
• More light output
• Less electrical power
• Increased lifetime
or
• A mix of all
Xenophot® technology (HLX)
Using xenon instead of krypton as the filling gas increases the luminous
efficacy of a lamp- that’s our basic idea behind our XENOPHOT technology.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
209
071_DO_drop.qxd
12/13/07
3:25 PM
Page 210
OSRAM aluPAR® Lamps with aluminum reflector
lighter, brighter, cooler
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Seeing is believing!
Don’t get weighed down with old technology!
Features and Benefits
•
Applications
Tungsten halogen aluPAR lamps are made with an aluminum
reflector which makes them up to 50% lighter than standard
glass PAR lamps.
– Lower transportation costs
– Easier handling
• aluPAR is an environmentally preferable ECOLOGIC® product
• Fully compatible with current market standards
•
•
•
Stage, Studio, Film
Concert/Disco lighting touring
Architectural lighting
SEE THE WORLD IN A NEW LIGHT
For more complete product information visit www.sylvania.com
210
Symbols/Footnotes on page 275-281
072_DOH_print.qxd
12/12/07
MR11, MR13, MR16
2:58 PM
Page 211
A21, A23
Bi-Pin
Med 2-pin
GZ9.5
PS25
AUDIOVISUAL
11
Avg
Rated
Life(hrs)
Bulb
Pkg
Qty
2000
MR16
24
8700
4
A21
12
G6.35
5600
50
T3.25
40
58
12
G6.35
1600
50
T3
40
58
1200
120
G17t
20
T7
24
13,58
Projector, Microfilm,
Stage & Studio
625
120
GY9.5
50
T6
24
58
CAX
Projector, Microfilm,
Microscope, Studio
50
120
DC Bayonet
250
T4
24
54660
DDL
Projector - Microfilm
150
20
GX5.3
500
MR16
24
117
DDM
54737
DDM
Projector - Slide
80
19
GX5.3
50
MR16
24
117
DDS
54944
DDS
Projector - Microfilm
80
21
GX5.3
1000
MR16
24
117
DED
54726
DED
Projector - Microfilm
85
13.8
GX5.3
150
1000
MR16
24
60,117
DNE
54409
DNE
Projector
150
120
G7.9
100
15
TB16
24
60,117
DNF
54411
DNF
Projector - 8mm
150
21
GX7.9
300
25
MR18
24
60,117
DYH
54561
DYH
Projector, Stage &
Studio
600
120
G5.3
17000
75
T6
24
DZE/FDS
54755
DZE/FDS
Projector, Microfilm,
Stage & Studio
150
24
GZ9.5
4000
100
T4
24
EBV
11558
EBV 118V
Super Photoflood/ No.2 500
120
Med
17800
8
PS25
24
ECA
13365
ECA 120V
Super Photoflood
250
120
Med Brass
6500
20
A23
24
ECT
11560
ECT 120V
Photoflood
500
120
Med
13650
60
PS25/5
24
EFM
54123
EFM 64607
Projector - 8mm
50
8
GZ6.35
50
MR16
20
60,117
EFN
54126
EFN 64615 HLX
Projector - 8mm
75
12
GZ6.35
50
MR16
20
60,117
EFP
54189
EFP 64627 HLX
Projector - 8mm
100
12
GZ6.35
50
MR16
20
60,117
EFP/X
54192
EFP/X 64629 HLX
Projector - 8mm
100
12
GZ6.35
600
MR16
20
60,117
EFR
54210
EFR 64634 HLX
Projector - 8mm
150
15
GZ6.35
50
MR16
20
60,117
EFR-5/X
54211
EFR-5/X 64620 HLX
Projector - 8mm
150
15
GY6.35
500
MR16
20
60,117
EHA
54585
EHA
Projector, Microfilm,
Stage & Studio
500
120
GY9.5
50
T6
24
13
EHE
54038
EHE 64626 HLX
Projector
100
12
PG22
3600
50
T4
30
58
EHJ
54254
EHJ 64655 HLX
Projector, Microfilm,
Microscope, Studio
250
24
G6.35
10000
50
T4
40
58
EHJ
54231
EHJ 64655 HLX BULK
Projector, Microfilm,
Microscope, Studio
250
24
G6.35
10000
50
T4
250
EHJ
54272
EHJ 64655 HLX/7X
Projector, Microfilm,
Microscope, Studio
250
24
G6.35
8000
700
T4
24
58
EJA
54753
EJA
Projector Fiber-optics
150
21
GX5.3
354
40
MR16
24
117
EJL
54730
EJL
Projector - 16mm
Color printer
200
24
GX5.3
725
50
MR16
24
117
EJM
54747
EJM
Projector - 8mm
150
21
GX5.3
170
40
MR16
24
117
EJV
54732
EJV
Projector - 8mm,
Printer
150
21
GX5.3
270
100
MR16
24
117
ANSI Code
Product
Number Ordering Abbreviation
Application
Watts Volts
Base
BAA
54924
BAA
Projector
75
28
GX5.3
BBA
11619
BBA 118V
Photoflood
250
No.1/Enlarger & Printer
120
Med
BRJ/EVB
54250
BRJ/EVB 64633 HLX
Projector, Microfilm,
Microscope, Studio
150
15
BRL
54249
BRL 64610 HLX
Projector, Microfilm,
Microscope, Studio
50
BRN
54698
BRN
Projector
BVE
54812
BVE
CAX
58831
DDL
For more complete product information visit www.sylvania.com
Lumens
750
400
Footnotes
|
|
|
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Symbols/Footnotes on page 275-281
211
072_DOH_print.qxd
12/12/07
MR11, MR13, MR16
2:58 PM
Page 212
Bi-Pin
AUDIOVISUAL
11
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Application
Watts Volts
Base
Lumens
Avg
Rated
Life(hrs)
EKE
Projector - 8mm,
Fiber-Optics
150
21
GX5.3
160
200
MR16
24
117
58771
EKE/X
Projector - 8mm,
Fiber-Optics
150
21
GX5.3
80
1000
MR16
24
117
EKP/ENA
54734
EKP/ENA
Projector - 8mm
80
30
GX5.3
115
25
MR16
24
117
ELC
54840
ELC
Overhead projection,
250
fiber-optic, entertainment
24
GX5.3
800
50
MR16
24
117
54804
ELC-HL
Overhead projection,
250
fiber-optic, entertainment
24
GX5.3
950
50
MR16
24
117
54212
ELC 64653 HLX
Overhead projection,
250
fiber-optic, entertainment
24
GX5.3
900
50
MR16
20
60,117
54841
ELC-3/X
Overhead projection,
250
fiber-optic, entertainment
24
GX5.3
550
300
MR16
24
117
54814
ELC-7/X
Overhead projection,
250
fiber-optic, entertainment
24
GX5.3
475
700
MR16
24
117
54811
ELC-7/X BULK
Overhead projection,
250
fiber-optic, entertainment
24
GX5.3
475
700
MR16
100
117
54366
ELC-10 64659 HLX
Overhead projection,
250
fiber-optic, entertainment
24
GX5.3
400
1000
MR16
20
117
ELD
54745
ELD
Projector - Microfilm
150
21
GX5.3
350
40
MR16
24
117
ELH
54776
ELH
Projector - Overhead
300
120
GY5.3
525
35
MR16
24
58,117
ENG
54957
ENG
Projector
300
120
GY5.3
690
15
MR16
24
58,117
ENH
54986
ENH
Projector - Slide
250
120
GY5.3
340
175
MR16
24
58,117
ENH
55002
ENH SPOT
Projector - Slide
250
120
GY5.3
340
175
MR16
24
58,117
ENH-5
54988
ENH-5
Projector - Overhead
250
125
GY5.3
340
175
MR16
24
58,117
ENL
58786
ENL
Projector - Display,
Fiber-Optics
50
12
GX5.3
85
4000
MR16
24
117
ENX
54984
ENX
Projector - Overhead
360
82
GY5.3
460
75
MR16
24
58,117
ENX-5
54913
ENX-5
Projector - Overhead
360
86
GY5.3
540
75
MR16
24
117
ENX-7
54916
ENX-7
Projector - Overhead
360
87.5
GY5.3
540
75
MR16
24
117
EPT
58782
EPT
Projector Fiber-Optics
42
10.8
GX5.3
8000
MR16
24
EPX
54927
EPX
Projector - Microfilm
90
14.5
GX5.3
43
500
MR16
24
60,117
EPZ
54743
EPZ
Projector - Microfilm
50
13.8
GX5.3
80
3000
MR16
24
60,117
ESA/FHD
54260
ESA/FHD 64225
Projector
10
6
G4
200
100
T3
40
ESB
54261
ESB 64250 HLX
Projector
20
6
G4
480
100
T3.5
40
ETJ
54928
ETJ
Projector
250
120
GY5.3
600
175
MR16
24
58,117
EVA
54251
EVA 64623 HLX
Projector, Microfilm,
Microscope, Studio
100
12
GY6.35
2800
2000
T4
40
58
EVC
54255
EVC 64657 HLX
Projector, Microfilm,
Microscope, Studio
250
24
G6.35
9000
300
T4
40
58
EVD
54259
EVD 64663 HLX
Projector, Microfilm,
Studio
400
36
GX6.35
16000
50
T6
40
58
EVW
54723
EVW
Projector
250
82
GY5.3
390
50
MR16
24
58,117
EXR
54392
EXR
Projector - Slide
300
82
GX5.3
925
35
MR13
24
58,117
EXW
54388
EXW
Projector - Slide
300
82
GX5.3
1050
15
MR13
24
58,117
EXY
54394
EXY
Projector - Slide
250
82
GX5.3
400
200
MR13
24
58,117
ANSI Code
Product
Number Ordering Abbreviation
EKE
54842
EKE/X
For more complete product information visit www.sylvania.com
212
Bulb
Pkg
Qty
Footnotes
|
|
|
Symbols/Footnotes on page 275-281
072_DOH_print.qxd
Bi-Pin
12/12/07
2:58 PM
Page 213
MR11, MR13, MR16
Med 2-pin
GZ9.5
B15d
E14
AUDIOVISUAL
11
Application
Watts Volts
Base
Lumens
Avg
Rated
Life(hrs)
EYB
Projector, Stage &
Studio
360
82
G5.3
10000
75
T3.5
24
58
54448
EYB-5
Projector, Microfilm,
Stage & Studio
360
85.5
G5.3
10000
75
T3.5
24
58
EYB-7
54455
EYB-7
Projector, Microfilm,
Stage & Studio
360
87.5
G5.3
10000
75
T3.5
24
58
EZE
54386
EZE
Projector, Stage &
Studio
150
82
GX5.3
350
150
MR13
24
58,117
FCR
54248
FCR 64625 HLX
Projector, Microfilm,
Microscope, Studio
100
12
GY6.35
3600
50
T3.5
40
58
FCS
54263
FCS 64640 HLX
Projector
150
24
G6.35
6000
50
T4
40
58
FDS/DZE
54277
FDS/DZE 64643
Projector, Microfilm,
Microscope, Studio
150
24
GY9.5
5000
100
T5
12
58
FDT
54276
FDT 64628
Projector, Stage &
Studio
100
12
GY9.5
3000
50
T4
12
58
FDV
54264
FDV 64642 HLX
Projector, Microfilm,
Microscope, Studio
150
24
G6.35
5000
300
T4
40
58
FHS
54979
FHS
Projector - Slide
300
82
GX5.3
650
70
MR16
24
58,117
FKT/EYH
54547
FKT/EYH
Projector - Video
Camera
250
120
G5.3
5400
200
T6
24
FLE
54383
FLE
Projector
360
82
GY5.3
1250
75
MR16
24
9,117
FNS
58849
FNS 64512
Projector, Stage &
Studio
300
120
GX6.35
9300
15
T6
12
58
FNT
54044
FNT 64656 HLX
Projector, Microfilm,
Microscope, Studio
275
24
G6.35
10000
75
T4
100
58
FNT
54253
FNT 64656 HLX
Projector, Microfilm,
Microscope, Studio
275
24
G6.35
10000
75
T4
40
58
FSX
54897
FSX/230
Projector
400
230
GY9.5
75
T6
24
13,58
FSY
54898
FSY
Projector
400
240
GY9.5
75
T6
24
13,58
FXL
54912
FXL
Projector - Overhead
410
82
GY5.3
640
75
MR16
24
58,117
FXL-HL
54904
FXL-HL
Projector - Overhead
410
82
GY5.3
850
40
MR16
24
58,117
GCB
54430
GCB
Projector, Stage &
Studio, Video
200
30
G5.3
5300
200
T3
24
54246
14V/35W/M/GZ4
Medical Overhead
Projection
35
14
GZ4
50
MR11
20
58729
60T4QCL
Medical Overhead
Illumination
60
24
DC Bayonet
500
T4
12
54400
85T3/RM
Projector
85
82
GX5.3
40
MR16
24
54466
120/T4/SPECIAL
Projector
120
24
Special
2750
500
T4
24
58939
220T4Q/2PPF
Medical Overhead
Illumination
220
22
GY9.35
6200
200
T4
12
58941
235T4Q/2PPF
Medical Overhead
Illumination
235
33
GZ9.5
5800
200
T4
12
76311
8013
Projector
10
6
BA15d
200
100
76313
8017
Projector
15
6
B15d
1000
100
76314
8018
Projector
15
76321
8100
Projector
54256
62138 HLX
Projector
ANSI Code
Product
Number Ordering Abbreviation
EYB
54446
EYB-5
For more complete product information visit www.sylvania.com
100
1280
Bulb
Pkg
Qty
Footnotes
117
59
6
B15d
100
100
34,59
E14
600
100
58
12
G6.35
40
60
50
T3
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
58,117
5
2800
|
|
|
Symbols/Footnotes on page 275-281
213
072_DOH_print.qxd
Bi-Pin
12/12/07
2:58 PM
MR11, MR13, MR16
Page 214
Med 2-pin
AUDIOVISUAL
11
ANSI Code
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Lumens
Avg
Rated
Life(hrs)
Bulb
Pkg
Qty
G4
150
300
T3
100
6
G4
150
300
T3
40
6
PG22
500
100
T3
30
20
8
GZX4
50
MR11
20
60,117
20
12
G4
350
2000
T3
40
58
Projector
20
12
G4
350
2000
T3
40
58
Projector
30
12
PG22
800
50
T3
30
64261
Projector
30
12
G6.35
750
50
T3.25
40
64265 HLX
Projector
30
6
G4
765
100
T2
100
54606
64265 HLX
Projector
30
6
G4
765
100
T2
40
54258
64275
Projector
35
6
G4
780
50
T3
40
54301
64291 XIR 40W
Medical
40
22.8
G6.35
1200
600
40
59,203
54302
64292 XIR 150W
Medical
150
22.8
G6.35
6000
600
40
59,203
54275
64513
Projector, Stage &
Studio
300
120
GX6.35
7700
150
T6
12
58
54354
64514
Projector, Stage &
Studio
300
120
GX6.35
8100
75
T6
12
58
58524
64515
Projector, Stage &
Studio
300
230
GX6.35
9600
15
T6
12
58
54356
64516
Projector, Stage &
Studio
300
230
GX6.35
7400
75
T6
12
11,58,202,211
54138
64602
Projector, Microfilm,
Microscope, Studio
50
12
G6.35
1000
1100
T3.25
100
58
54607
64602
Projector, Microfilm,
Microscope, Studio
50
12
G6.35
1000
1100
T3.25
40
58
54028
64611 HLX
Projector
50
12
G6.35
1350
100
T3.25
100
58
54608
64611 HLX
Projector
50
12
G6.35
1350
54124
64617
Projector
75
12
G5.3-4.8
54121
64617 SPOT
Projector
75
12
G5.3-4.8
54032
64621 HLX
Projector, Microfilm,
Stage & Studio
100
12
PG22
54125
64624
Projector
100
12
G5.3-4.8
54233
64635 HLX
Projector, Fiber-Optic
150
15
GZ6.35
54214
64637
Projector
100
12
GZ6.35
54252
64638 HLX
Projector
100
24
G6.35
2900
54257
64650
Projector, Microfilm,
Microscope, Studio
50
23
G6.35
1000
54278
64654 HLX
Projector, Microfilm,
Microscope, Studio
250
24
GY9.5
54273
64664 HLX
Projector, Microfilm,
Microscope, Studio
400
36
54274
64665 HLX
Projector, Microfilm,
Microscope, Studio
400
54303
64668 XIR 80W
Medical
80
76305
70313 (390158)
Special Purpose
30
6
P47d
100
76304
70314 (390153)
Special Purpose
25
6
P47d
100
Product
Number Ordering Abbreviation
Application
Watts Volts
Base
54050
64223
Projector
10
6
54245
64223
Projector
10
54021
64251 HLX
Projector
20
54122
64255
Projector
54901
64258 AHLX
Projector
54262
64258 HLX
54022
64260
54247
53999
For more complete product information visit www.sylvania.com
214
Footnotes
100
T3.25
40
58
25
MR11
20
60,117
25
MR11
20
60,117
2000
T3
30
58
25
MR11
20
60,117
50
MR16
20
60,117
1500
MR16
20
58,117
300
T3
40
1300
T4
40
9000
300
T6
12
58
G6.35
14500
150
T6
12
58,267
36
G6.35
400
300
T6
12
58
22.8
G6.35
3000
750
40
59,203
2750
|
|
|
Symbols/Footnotes on page 275-281
072_DOH_print.qxd
12/12/07
Med 2-pin
2:58 PM
A21, A23
Page 215
GZ9.5
Bi-Pin
P28s
P40s
PAR36
R7s, RX7s
G22
Med Bi-pin
AUDIOVISUAL
11
ANSI Code
Product
Number Ordering Abbreviation
Application
Watts Volts
Base
76302
70335 BULK
Special Purpose
27
6
Special
54793
JCP 650W/100V
Overhead projection,
650
fiber-optic, entertainment
100
GY9.5
Lumens
Avg
Rated
Life(hrs)
Bulb
Pkg
Qty
Footnotes
|
|
|
Footnotes
|
|
|
200
18750
100
T6
12
Bulb
Pkg
Qty
STUDIO,THEATRE, TV & VIDEO
11c
ANSI Code
Product
Number Ordering Abbreviation
Color
Temp (K)
Watts Volts
Base
Lumens
Avg
Rated
Life(hrs)
BCA
11655
BCA 118V
4800
250
120
Medium
8912
12
A21
12
BHC/DYS/DYV
54836
BHC/DYS/DYV
600
120
GZ9.5
17500
75
T6
24
58
BHC/DYS/DYV-5
54835
BHC/DYS/DYV-5
600
125
GZ9.5
17500
75
T6
24
16,58
BCM
54694
BCM
3200
20000 230
G38
580000
350
T32
1
58
BTL
54685
BTL
3050
500
120
P28s
11000
750
T6
12
BTM
54686
BTM
3200
500
120
P28s
13000
100
T6
12
58
BTN
54687
BTN
3200
750
120
P28s
17000
500
T7
12
58
BTP
54688
BTP
3200
750
120
P28s
20000
200
T7
12
BTR
54689
BTR
3200
1000
120
P28s
27500
250
T6
12
58
BVM
58827
BVM 64540
3400
650
230
GZ6.35
20000
15
T8
12
11
BVT
54690
BVT
3050
1000
120
P40s
23000
500
T7
6
BVV
54691
BVV
3200
1000
120
P40s
27500
200
T6
6
BVW
54692
BVW
3200
2000
120
P40s
59000
280
T9.5
6
CXZ
54717
CXZ
3200
1500
120
G38
38500
325
T8
6
CYV
54706
CYV
3200
1000
120
G38
27500
200
T7
6
CYX
54613
CYX
3200
2000
120
G38
55000
300
T11
6
DNS/FMC
54655
DNS/FMC
3050
500
120
P28s
11000
500
T6
24
DPY
54647
DPY
3200
5000
120
G38
143000
500
T17
1
DTA
54716
DTA
3200
1500
120
P40s
39000
100
T8
6
DTY
54696
DTY
3200
10000 120
G38
290500
350
T24
1
DWE
54500
DWE
3200
650
120
G53
24000
100
PAR36
1
DWT
58937
DWT
3000
1000
120
RX7s
22000
2000
T6
12
DXW
53997
DXW
3200
1000
120
R7s
28000
150
T5
12
120
58
58
58
101
58497
DYS/300
3200
300
GZ9.5
7500
100
T4
24
ECR
54702
ECR 64815 CP/83 230V
3200
10000 230
G38
280000
400
T22
6
EFX
54787
EFX
3000
500
120
G22
10000
2000
T5
12
EGE
54648
EGE
3000
500
120
P28s
10000
2000
T5
12
EGG
54652
EGG
3000
750
120
P28s
15000
2000
T5
12
EGJ
54654
EGJ
3200
1000
120
P28s
25500
400
T6
12
EGK
54656
EGK
3200
1000
120
P28s
24500
400
T6
12
EGN
54659
EGN
3200
500
120
G22
13000
100
T6
12
58
EGR
54662
EGR
3200
750
120
G22
20000
200
T7
12
58
EGT
54664
EGT
3200
1000
120
G22
27500
250
T6
12
58
EGW
58510
EGW 64535
3400
650
120
GY6.35
20000
15
T8
12
EHC/EHB
54506
EHC/EHB
3200
500
120
G9.5
13000
300
T4
12
For more complete product information visit www.sylvania.com
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
58
Symbols/Footnotes on page 275-281
215
072_DOH_print.qxd
12/12/07
Med Bi-pin
2:58 PM
R7s, RX7s
Page 216
GZ9.5
Bi-Pin
G22
Med 2-pin
STUDIO,THEATRE, TV & VIDEO
11c
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Lumens
Avg
Rated
Life(hrs)
Bulb
Pkg
Qty
G9.5
10600
2000
T4
12
120
G9.5
20400
300
T5
12
120
G9.5
15400
2000
T5
12
300
120
R7s
5000
2500
T4
12
400
120
R7s
7500
2000
T4
12
3200
750
120
R7s
20600
400
T3
12
60
3200
420
120
GZ9.5
11000
75
T6
24
58
FAD
3200
650
120
R7s
16500
100
T4
12
FAL
3200
420
120
R7s
11000
75
T4
24
54483
FCB
3200
600
120
R7s
16500
75
T4
24
54442
FCM
3200
1000
120
R7s
28000
400
T3
12
60
FDA
54471
FDA
3200
400
120
R7s
10400
250
T4
12
24
FDB
54435
FDB
3200
1500
120
R7s
41200
400
T4
12
60
FDG
54387
64579 115-120V
3200
1000
120
R7s
33000
15
T4
12
12
FDN
54534
FDN
3200
500
120
R7s
12800
400
T2.5
12
60
FEL
54570
FEL
3200
1000
120
G9.5
27500
300
T6
12
FEP
54515
FEP/240
3200
1000
240
G9.5
23000
150
T6
12
FER
54571
FER
3200
1000
120
RX7s
27500
500
T6
12
FEV
54441
FEV
3200
200
120
DC Bayonet
5500
50
T4
12
FEX
54514
FEX/230
3200
2000
230
RX7s
50000
300
T8
12
FEX
54518
FEX/240
3200
2000
240
RX7s
50000
300
T8
12
FEY
54559
FEY
3200
2000
120
RX7s
57400
400
T8
12
FFJ
54488
FFJ
3200
600
120
R7s
16500
75
T4
24
24
FFM
58862
FFM
3200
420
120
R7s
11000
75
T4
24
24
FFT
54350
FFT
3200
1000
120
R7s
27000
300
T3
12
FHM
54532
FHM
3200
1000
120
R7s
27300
300
T3
12
60
FKJ
54681
FKJ CP/71
3200
1000
230
G22
26000
200
T6
20
58
FKK
54699
FKK CP/73
3200
2000
230
G38
52000
400
T11
1
58
FKW
54711
FKW
3200
300
120
GY9.5
7800
200
T6
24
58
FLK
54589
FLK
3200
575
115
G9.5
16500
300
T5
12
188
FLK
54551
FLK/X 115V
3200
575
115
G9.5
10000
2000
T5
12
188
54549
FLK PLUS HPR 575/115
3200
575
115
G9.5
16500
300
T6
12
187
54412
FMR
3000
600
120
GY9.35
12500
2000
T5
24
FRG
54629
FRG
3200
500
120
GY9.35
13000
150
T6
24
58
FRK
54631
FRK
3200
650
120
GY9.5
16900
200
T7
24
58
FRL
54638
FRL CP/89
3200
650
230
GY9.5
16250
150
T7
25
58
FSH
54436
FSH
3200
125
120
G5.3
2500
200
T3
24
FTK
54875
FTK
3200
500
120
GY9.5
12000
200
T6
24
FVL
54459
FVL
3200
200
120
GX5.3
5200
200
T4
24
FVM
54900
FVM
3200
105
120
GX5.3
2250
250
T4
24
GCA
54428
GCA
3200
250
120
G5.3
5700
200
T3
24
GLA
54516
GLA 575/115/2000
3050
575
115
G9.5
10500
2000
T6
12
ANSI Code
Product
Number Ordering Abbreviation
Color
Temp (K)
Watts Volts
Base
EHD
54508
EHD
3000
500
120
EHF
54510
EHF
3300
750
EHG
54512
EHG
3000
750
EHP
58942
EHP
2900
EHR
58936
EHR
3000
EJG
54598
EJG
EKB
54837
EKB
FAD
54574
FAL
58860
FCB
FCM
FMR
For more complete product information visit www.sylvania.com
216
Footnotes
|
|
|
24
11
58
18
Symbols/Footnotes on page 275-281
072_DOH_print.qxd
Med Bi-pin
12/12/07
2:58 PM
Bi-Pin
Page 217
S11
S14
R7s, RX7s
PAR36
A21, A23
HPL
G22
STUDIO,THEATRE, TV & VIDEO
11c
Lumens
Avg
Rated
Life(hrs)
G9.5
15500
115
G9.5
115
G9.5
235
230
75
120
2900
75
120
Medium
1150
35
S14
24
2700
150
25
R7s
2700
3000
T4
25
20
12
G53
4000
PAR36
12
75
120
Medium
200
A21
12
ANSI Code
Product
Number Ordering Abbreviation
Color
Temp (K)
Bulb
Pkg
Qty
Watts Volts
Base
Footnotes
GLC
54507
GLC 575/115/300
3250
575
115
300
T6
12
18,20
GLD
54522
GLD 750/115/300
3250
750
GLE
54523
GLE 750/115/1500
3050
750
19000
300
T6
12
18
17400
1500
T6
12
GLF
54460
GLF
3100
11624
111A
2900
G5.3
5100
100
T4
24
SC Bayonet
1120
15
S11
24
11625
140
58930
150/25T4
55052
20PAR/36/CAP/WFL
11657
211 118V
3200
11656
212 118V
3050
54499
4515 PAR36 30W
54001
64501
58639
64573
58958
1215
150
120
Medium
2700
200
A21
12
30
6
G53
67000
100
PAR36
12
3400
150
120
GX6.35
4500
25
T4
25
3400
1000
120
GX6.35
33000
15
T8
25
64573
3400
1000
120
GZ6.35
33000
15
T8
12
58525
64575
3400
1000
230
GX6.35
33000
15
T8
12
54232
64614
75
12
G5.3-4.8
25
T2.5
20
60
54701
64805 CP/85 (CP/29)
3200
5000
230
G38
135000
400
T19
1
58
58497
DYS/300
3200
300
115
GZ9.5
7500
100
T6
24
54625
HPL 375/115 (UCF)
3200
375
115
Sp Med Bipin
10540
300
T6
12
26
54649
HPL 375/115/X (UCF)
2950
375
115
Sp Med Bipin
8000
1000
T8
12
26
54623
HPL 550/77 (UCF)
3265
550
77
Sp Med Bipin
16170
300
T6
12
26
54604
HPL 550/77/X (UCF)
3065
550
77
Sp Med Bipin
12160
1500
T6
12
26
54622
HPL 575/115 (UCF)
3265
575
115
Sp Med Bipin
16520
300
T6
12
26
54807
HPL 575/115/X (UCF)
3065
575
115
Sp Med Bipin
12360
1500
T6
12
26
54817
HPL 575/120 (UCF)
3265
575
120
Sp Med Bipin
16460
300
T6
12
26
54815
HPL 575/120/X (UCF)
3050
575
120
Sp Med Bipin
12360
1500
T6
12
26
54618
HPL 575/230 (UCF)
3200
575
230
Sp Med Bipin
14900
400
T6
12
26
54665
HPL 575/230/X (UCF)
3050
575
230
Sp Med Bipin
11780
1500
T6
12
26
54619
HPL 575/240 (UCF)
3200
575
240
Sp Med Bipin
14900
400
T6
12
26
54703
HPL 575/240/X (UCF)
3050
575
240
Sp Med Bipin
11780
1500
T6
12
26
54602
HPL 750/115 (UCF)
3265
750
115
Sp Med Bipin
21900
300
T6
12
26
54611
HPL 750/115/X (UCF)
3050
750
115
Sp Med Bipin
16400
1500
T6
12
26
54605
HPL 750/120 (UCF)
3250
750
120
Sp Med Bipin
21900
300
T6
12
26
54653
HPL 750/120/X (UCF)
3065
750
120
Sp Med Bipin
16400
1500
T6
12
26
54603
HPL 750/230 (UCF)
3200
750
230
Sp Med Bipin
19750
300
T6
12
26
54670
HPL 750/230/X (UCF)
3050
750
230
Sp Med Bipin
15600
1500
T6
12
26
54614
HPL 750/240 (UCF)
3200
750
240
Sp Med Bipin
19750
300
T6
12
26
54704
HPL 750/240/X (UCF)
3050
750
240
Sp Med Bipin
15600
1500
T6
12
26
54825
HPL 750/77 (UCF)
3265
750
77
Sp Med Bipin
22950
300
T6
12
26
54798
HWHV 1200W/220V
3200
1200
220
GX9.5
33500
300
T7
12
207
54799
HWLV 1200W/80V
3200
1200
80
G22
37500
300
T7
12
207
54796
HWMV 1200W/115V
3200
1200
115
GX9.5
37000
300
T7
12
207
For more complete product information visit www.sylvania.com
|
|
|
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Symbols/Footnotes on page 275-281
217
072_DOH_print.qxd
12/12/07
QXL
2:58 PM
STUDIOLINE
Page 218
PAR 56, 64
STUDIO,THEATRE, TV & VIDEO
11c
ANSI Code
Lumens
Avg
Rated
Life(hrs)
QXL
22950
QXL
2G11
Product
Number Ordering Abbreviation
Color
Temp (K)
Watts Volts
Base
54882
QXL 750/77
3250
750
77
54883
QXL 750/77/X
3050
750
77
20607
STUDIOLINE 55W/3200
3200
55
20608
STUDIOLINE 55W/5600
5600
55
|
|
|
Bulb
Pkg
Qty
Footnotes
300
T6
12
178,180,181,184
18000
1500
T6
12
178,180,181,184
3800
8000
T5
10
2G11
3800
8000
T5
10
Avg
Rated
Life(hrs)
Bulb
Pkg
Qty
Footnotes
LARGE PAR - ALUPAR®
11b
ANSI Code
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
Product
Number Ordering Abbreviation
Luminous
Intensity (cd)
Watts Volts
Base
Color
Temp (K)
56003
aluPAR 56/NSP/300W/120V
68000
300
120
GX16d
2950
2000
PAR56
6
30,198,199
56004
aluPAR 56/MFL/300W/120V
24000
300
120
GX16d
2950
2000
PAR56
6
29,198,199
56005
aluPAR 56/WFL/300W/120V
11000
300
120
GX16d
2950
2000
PAR56
6
31,198,199
56000
aluPAR 56/NSP/300W/230V
70000
300
230
GX16d
2950
2000
PAR56
6
30,198,199
56001
aluPAR 56/MFL/300W/230V
30000
300
230
GX16d
2950
2000
PAR56
6
29,198,199
56002
aluPAR 56/WFL/300W/230V
10000
300
230
GX16d
2950
2000
PAR56
6
31,198,199
56086
aluPAR 56/NSP/500W/120V
96000
500
120
GX16d
2950
4000
PAR56
6
30,198,199
56213
aluPAR 56/MFL/500W/120V
45000
500
120
GX16d
2950
4000
PAR56
6
29,198,199
56006
aluPAR 56/WFL/500W/120V
21000
500
120
GX16d
2950
4000
PAR56
6
31,198,199
56007
aluPAR 64/NSP/500W/120V
110000
500
120
GX16d
2950
2000
PAR64
6
30,198,199
56008
aluPAR 64/MFL/500W/120V
37000
500
120
GX16d
2950
2000
PAR64
6
29,198,199
56009
aluPAR 64/WFL/500W/120V
13000
500
120
GX16d
2950
2000
PAR64
6
31,198,199
56018
aluPAR 64/NSP/500W/230V
140000
500
230
GX16d
3200
300
PAR64
6
30,198,199
56019
aluPAR 64/MFL/500W/230V
65000
500
230
GX16d
3200
300
PAR64
6
29,198,199
56017
aluPAR 64/VNSP/1000W/120V
400000
1000
120
GX16d
3200
800
PAR64
6
32,198,199
56010
aluPAR 64/NSP/1000W/120V
330000
1000
120
GX16d
3200
800
PAR64
6
30,198,199
56011
aluPAR 64/MFL/1000W/120V
12000
1000
120
GX16d
3200
800
PAR64
6
29,198,199
56012
aluPAR 64/WFL/1000W/120V
40000
1000
120
GX16d
3200
300
PAR64
6
31,198,199
56014
aluPAR 64/NSP/1000W/230V
297000
1000
230
GX16d
3200
300
PAR64
6
30,198,199
56015
aluPAR 64/MFL/1000W/230V
138000
1000
230
GX16d
3200
300
PAR64
6
29,198,199
56016
aluPAR 64/WFL/1000W/230V
38000
1000
230
GX16d
3200
300
PAR64
6
31,198,199
Avg
Rated
Life(hrs)
Bulb
Pkg
Qty
Footnotes
|
|
|
LARGE PAR - OTHER
11b
ANSI Code
Product
Number Ordering Abbreviation
Luminous
Intensity (cd)
Watts Volts
Base
Color
Temp (K)
EXC
56280
EXC/230
320000
1000
230
GX16d
3200
300
PAR64
6
27,30
EXC
56232
EXC/240
320000
1000
240
GX16d
3200
300
PAR64
6
27,30
EXD
56281
EXD/230
270000
1000
230
GX16d
3200
300
PAR64
6
27
EXD
56233
EXD/240
270000
1000
240
GX16d
3200
300
PAR64
6
27
EXE
56283
EXE/230
125000
1000
230
GX16d
3200
300
PAR64
6
27
EXE
56234
EXE/240
125000
1000
240
GX16d
3200
300
PAR64
6
27
FFN
56214
FFN
400000
1000
120
GX16d
3200
800
PAR64
6
27,32
FFP
56215
FFP
330000
1000
120
GX16d
3200
800
PAR64
6
27,30
FFR
56217
FFR
125000
1000
120
GX16d
3200
800
PAR64
6
27,29
For more complete product information visit www.sylvania.com
218
|
|
|
Symbols/Footnotes on page 275-281
072_DOH_print.qxd
12/12/07
2:58 PM
PAR 56, 64
Page 219
RSC
Med Bi-pin
G22
B15d
E14
STUDIO,THEATRE, TV & VIDEO
LARGE PAR - OTHER
11b
Base
Color
Temp (K)
Avg
Rated
Life(hrs)
120
GX16d
3200
75
MEP
ANSI Code
Product
Number Ordering Abbreviation
Luminous
Intensity (cd)
Watts Volts
FFS
56216
FFS
40000
1000
14974
350PAR56/SP
350
Bulb
Pkg
Qty
Footnotes
800
PAR64
6
27,31
750
PAR56
12
27
|
|
|
SPECIAL PURPOSE HEAT LAMPS
12
ANSI Code
FRN
Avg
Rated
Life(hrs)
Bulb
Pkg
Qty
Footnotes
5000
T3
12
139
T3
12
139
T6
12
121
Product
Number
Ordering Abbreviation
Watts
Volts
Base
59850
500T3Q/IR 120V
500
120
Flex Nick Leads
59822
500T3Q/IR/7 120V
500
120
RSC
5000
54555
1000Q/T6/RTP/C
1000
120
G9.5
27500
300
54584
1000Q/T6/RTPFS
1000
120
G9.5
27500
300
T6
12
54752
1000T6QRTP/X
1000
120
G9.5
25000
2000
T6
12
54560
1000TQ/RTP/CR/BULK
1000
120
G9.5
25000
2000
T6
12
54633
1500T6Q/RTP/GS
1500
120
G9.5
42000
300
T6
12
54537
2000T8Q/120V/G22
2000
120
G22
45000
2000
T8
12
54588
FRN 2000T7Q
2000
120
G9.5
56500
200
T7
12
54548
2500T8Q/120V
2500
120
GY9.5
75000
300
T6
12
59934
1200T3Q/IR/CL/HT 144V
1200
144
Flex Nick Leads
3000
T3
12
121,125,139
59860
1000T3Q/IR 230-250V
1000
240
Flex Nick Leads
139
54521
1000/240V/G9.5
1000
240
G9.5
59864
1600T3Q/IR 240V
1600
240
Flex Nick Leads
5000
T3
12
139
59841
1600T3Q/IR/7 240V
1600
240
RSC
5000
T3
12
139
59936
1600T3Q/IR 277V
1600
277
Flex Nick Leads
5000
T3
12
139
59867
2500T3Q/IR 480V
2500
480
Flex Nick Leads
5000
T3
12
139
59803
2500T3Q/IR/7 480V
2500
480
RSC
5000
T3
12
139
59859
3650T3Q/IR/CL 480V
3650
480
Flex Nick Leads
5000
T3
12
139
59870
3800T3Q/IR 570V
3800
570
Flex Nick Leads
5000
T3
12
139
Pkg
Qty
Footnotes
59
Lumens
23000
5000
T3
12
150
T6
12
|
|
|
127
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
184
OPTOELECTRONICS
15
Ordering Abbreviation
Product Number
Watts
Volts
Base
Operating Position
Avg
Rated
Life(hrs)
8013
76311
10
6
BA15d
h 105
200
100
8017
76313
15
6
BA15d
Any
1000
100
8018
76314
15
6
BA15d
h 30
100
100
34,59
8100
76321
6
E14
s 105
600
100
58
70314 (390153)
76304
25
6
P47d
100
70335 BULK
76302
27
6
Special
200
|
|
|
AIRCRAFT
13
Watts
Bulb
Volts Base
Product
Number
100
T3
12
54032
PG22
Ordering Abbreviation Application
64621 HLX
For more complete product information visit www.sylvania.com
Aircraft
Beam
Type CBCP
Avg
Rated
MOL Pkg
Filament Life(hrs) (mm) Qty Footnotes
2000
48
30
|
|
|
58
Symbols/Footnotes on page 275-281
219
072_DOH_print.qxd
12/12/07
PAR46,64
2:58 PM
Page 220
MR11, MR16 (leads)
AIRCRAFT
13
Ordering Abbreviation Application
Beam
Type CBCP
Avg
Rated
MOL Pkg
Filament Life(hrs) (mm) Qty Footnotes
Watts
Bulb
250
PAR46 28
G53
15399
4551
Aircraft Taxiing
VNSP 75000
CC-6
25
95.25 12
32
450
PAR46 28
G53
56229
Q4681
Aircraft Landing /
Taxiway
VNSP 310000
CC-6
50
63.5
27,32
600
PAR64 28
G53
14936
4559
Aircraft Landing /
Taxiway
VNSP 600000
CC-8
25
101.6 6
32
56222
Q4559
Aircraft Landing /
Taxiway
VNSP 600000
CC-8
100
101.6 6
27,32
56223
Q4559X
Aircraft Landing /
Taxiway
VNSP 765000
CC-8
100
101.6 6
27,32
14988
4557
Aircraft
Landing/Taxiway
VNSP 540000
CC-8
25
101.6 6
32
14994
5557
Aircraft
Landing/Taxiway
VNSP 540000
CC-8
50
101.6 6
32,67
1000
Volts Base
Product
Number
PAR64 28
G53
12
|
|
|
AIRFIELD
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
14
Watts
Bulb
30
MR16 Leads-A
40
45
Base
Ordering Abbreviation
Application
Avg
Current
Rated LCL MOL Pkg
(A)
Lumens Filament Life(hrs) (mm) (mm) Qty Footnotes
58964
6.6A/30MR16/64331A/FL
Airfield / Airport
6.6
1000
45.6
20
205
58506
6.6A/30MR16/64331A/SP
Airfield/Airport
6.6
1000
45.6
20
205
Leads-A/C
58730
6.6A/30MR16/64331AC/FL
Airfield / Airport
6.6
1000
45.6
10
138
58938
6.6A/30MR16/64331AC/FL
Airfield / Airport
6.6
45.6
20
138
T3.5
GZ9.5
58850
6.6A/30T3.5/64322/EXL/DL
Airfield/Airport
6.6
44.5
12
58893
6.6A/30T3.5/EXL
Airfield/Airport
6.6
600
C-8
1000
25.4
44.5
12
T10
Med Prefocus
17980
6.6A/30T10/1P
Airfield/Airport
6.6
400
C-2V
1000
38.1
100
60
MR11 Leads-A
58899
6.6A/40MR11/64333A
Airfield / Airport
6.6
1500
37
20
205
Leads-B
58787
6.6A/40MR11/64333B
Airfield / Airport
6.6
1500
37
10
208
58889
6.6A/40MR11/64333B
Airfield / Airport
6.6
1500
37
20
208
58545
6.6A/45MR16/64337A 45-15
Airfield / Airport
6.6
1500
45.6
10
205
MR16 Leads-A
C-8
2000
25.4
58907
6.6A/45MR16/64337A 45-15
Airfield / Airport
6.6
1500
45.6
20
205
58758
6.6A/45MR16/64337B 45-15
Airfield / Airport
6.6
1500
45.6
10
208
58908
6.6A/45MR16/64337B 45-15
Airfield / Airport
6.6
45.6
20
208
T3
R7s
58704
6.6A/45T3/CL/64315
Airfield/Airport
6.6
47.5
25
T3.5
G6.35
59928
6.6A/45T3.5Q/64321
Airfield / Airport
6.6
840
C-8
1200
33
45
40
58,60
58813
6.6A/45T3.5Q/64321
Airfield / Airport
6.6
840
C-8
1200
33
45
100
58,60
58846
6.6A/45T3.5/64320/EXM
Airfield/Airport
6.6
875
C-8
1000
25.4
44.5
12
58,60
58892
6.6A/45T3.5/EXM
Airfield/Airport
6.6
875
C-8
1000
25.4
44.5
12
58,60
T4
PK30d-A
PK30d-C
T10
Med Prefocus
MR16 Leads-A
Leads-A/C
1500
750
C-8
1000
23
58697
6.6A/45T4/64319 FEMALE
Airfield/Airport
6.6
800
C-8
1000
20
53
100
58,120,205,271
58877
6.6A/45T4CL/64318
Airfield/Airport
6.6
800
C-8
1000
16
58
100
58,205,271
58705
6.6A/45T4/CL/64317
Airfield/Airport
6.6
800
C-8
1000
16
58
100
58,209
58722
6.6A/45T4/64319Z
Airfield/Airport
6.6
800
C-8
1000
20
53
100
58,121,209,268
17981
6.6A/45T10/P
Airfield/Airport
6.6
675
C-2V
1000
38.1
100
60
58891
6.6A/48MR16/64337A 48-15
Airfield/Airport
6.6
1500
45.6
20
205,271
58905
6.6A/48MR16/64337A LL IRC
Airfield/Airport
6.6
3000
45.6
20
205,271
58894
6.6A/48W/MR16/64338AC
Airfield / Airport
6.6
1000
45.6
20
58
For more complete product information visit www.sylvania.com
220
1000
400
Leads-B
GZ9.5
48
Product
Number
|
|
|
Symbols/Footnotes on page 275-281
072_DOH_print.qxd
12/12/07
PK30d
2:58 PM
Page 221
MR11, MR16 (leads)
Med 2-pin
AIRFIELD
14
Base
Product
Number
Ordering Abbreviation
Application
Avg
Current
Rated LCL MOL Pkg
(A)
Lumens Filament Life(hrs) (mm) (mm) Qty Footnotes
Watts
Bulb
48
MR16 Leads-B
58906
6.6A/48MR16/64337B LL IRC
Airfield/Airport
6.6
3000
45.6
Leads-C
58952
6.6A/48MR16/64337C LL IRC
Airfield/Airport
6.6
3000
62
MR16 Leads-A
58493
6.6A/62W/MR16/64336A
Airfield/Airport
6.6
1500
65
T4
PK30d-C
58726
6.6A/65T4/64328Z/HLX
Airfield/Airport
6.6
100
T4
PK30d-A
58709
6.6A/100T4/64341/HLX
Airfield/Airport
6.6
PK30d-C
105
MR16 Leads-A
Leads-A/C
Leads-B
1450
20
208,271
45.6
20
209
44
20
205
C Bar 6
1000
20
53
100
58,123,209,268
C Bar 6
1000
20
55
100
58,205,271
58703
6.6A/100T4/64341Z/HLX
Airfield/Airport
6.6
2700
C Bar 6
1000
20
55
100
125,209,268
58706
6.6A/100T4/64342/HLX
Airfield/Airport
6.6
2700
C Bar 6
1000
20
58
100
58,209
58953
6.6A/105MR16/64339A
Airfield / Airport
6.6
1000
45.6
20
205,271
58960
6.6A/105MR16/64339AC
Airfield/Airport
6.6
1000
45.6
20
138
58759
6.6A/105MR16/64339B
Airfield/Airport
6.6
1000
45.6
10
208
58961
6.6A/105MR16/64339B
Airfield/Airport
6.6
1000
45.6
20
208
Leads-C
58963
6.6A/105MR16/64339C
Airfield / Airport
6.6
45.6
20
209,268
115
T4
GY9.5
58854
6.6A/115T4Q/58798/2PPF/EVV
Airfield/Airport
6.6
2900
C Bar 6
1000
39.1
57
12
140
150
T4
GY9.5
58855
6.6A/150T4Q/64354/EWR/DL
Airfield/Airport
6.6
4000
C Bar 6
1500
39.1
56.5
12
140
58777
6.6A/150T4Q/64354/EWR/DL
Airfield/Airport
6.6
4000
C Bar 6
1500
39.1
56.5
30
58,140
PK30d-A
58717
6.6A/150T4/64361/HLX
Airfield/Airport
6.6
3600
C Bar 6
1000
20
58
100
58,205,271,274
PK30d-C
58724
6.6A/150T4Q/64361Z/HLX
Airfield/Airport
6.6
3600
C Bar 6
1000
20
58
100
58,209,268
PAR64 GX16d
56220
6.6A/200PAR64Q/2P
Airfield/Airport
6.6
CC-6
2000
114.3 6
27,278
T4
59078
6.6A/200T4Q/64386
Airfield / Airport
6.6
4700
C Bar 6
1200
33
47
40
58,60
Airfield / Airport
200
T5
G6.35
1000
58815
6.6A/200T4Q/64386
6.6
4700
C Bar 6
1200
33
47
100
58
GY9.5
58851
6.6A/200T4Q/2PPF/58750/EZL/DL Airfield/Airport
6.6
5200
CC-6
1000
39.1
65
12
140
P30d
58821
6.6A/200T4Q/CL/DCR/58746/DL Airfield/Airport
6.6
5000
CC-6
1000
27
80.9
100
58,60
PK30d-A
58649
6.6A/200T4/64382A/HLX
Airfield/Airport
6.6
4800
CC-6
1000
20
64
100
58,205
PK30d-C
58708
6.6A/200T4/64382C/HLX
Airfield/Airport
6.6
4800
CC-6
1000
20
64
100
58,209,273
R7s
58707
6.6A/200T5/CL/64380
Airfield/Airport
6.6
4400
CC-8
1000
21.3
60.2
25
For more complete product information visit www.sylvania.com
|
|
|
Symbols/Footnotes on page 275-281
221
D
I
S
P
L
A
Y
O
P
T
I
C
H
A
L
O
G
E
N
071_DO_drop.qxd
12/13/07
3:25 PM
Page 222
4ArXS (For Architainment eXtreme Seal)
Innovative metal halide lamps for creative
architectural and effect lighting
4 ArXS HSD®
4ArXS HSD are new powerful metal halide lamps from OSRAM
with innovative eXtreme Seal technology. The 4ArXS opens up new
prospects for creative architectural and
effect lighting.
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Optimized lamp seal technology to withstand interior base
temperatures up to 450 °C.
Features and Benefits:
•
•
•
•
•
Average service life of 2000 to
6000 hours
Outstanding luminous intensity and color consistency
throughout the life
of the lamp
Low devitrification of the bulb wall
Daylight type (6000 K) and “bright light” type (7000 – 8000K)
Simple and reliable cold starting
Applications:
•
•
•
•
Architectural lighting
Projected advertising
Nightclub lighting
TV shows, concerts, musicals
and theatre
LIGHT THEM UP!
For more complete product information visit www.sylvania.com
222
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 223
SharXS® HTI® from OSRAM
The original light with a bite
The SharXS (Short arc eXtreme Seal) HTI family uses state-of-the-art HTI technology to achieve a particularly high luminous efficacy. The arc
in these innovative light sources has been reduced to 3-7mm. What this means for you is the SharXS HTI produces a higher luminance from
the same wattage and therefore saves electricity and reduces operating costs.
Features and Benefits
•
•
•
•
•
Ideal for intelligent luminaires
Less sensitive to heat
Always ready for a hot restart
Allows more compact luminaire design
Pre-focus base for accurate lamp installation
OSRAM SFc10-4 Pre-focus socket with its unique high
performance contact system pairs with all lamp wattages
eXtreme-Seal (XS) Technology
Optimized lamp seal technology to withstand interior base
temperatures up to 450 °C.
•
•
•
•
Moving heads
Scanners
Projectors
Color changers
SharXS HTI in its element
SharXS lamps are at home in all areas of entertainment lighting
• Shows
• Clubs
• Special Events
• Concerts
• TV studios
• Advertising and retail
Baby SharXS® HTI® from OSRAM
An offspring with just as sharp of a bite
SharXS HTI now in just 93mm
Measuring only 93mm, the latest offspring in the family has all the benefits of the full-size
OSRAM SharXS HTI.
• Short 5mm arc for greater efficiency
• eXtreme Seal(XS) technology for improved thermal loading
• Modular design with the same dimensions for all wattages
Good genes: the new Baby SharXS
The tiny Baby SharXS develops all its power from just 93mm. The small dimensions of
the Baby SharXS will inspire designers to create compact luminaires. Because of their
lower weight, not only will these luminarirs be easier to handle but more of them will fit on
a lighting rig.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
223
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
071_DO_drop.qxd
12/13/07
3:25 PM
Page 224
NOTES:
r
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
For more complete product information visit www.sylvania.com
224
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 225
HMI® METAL HALIDE
1
2
3
4
HMI® SINGLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMI 200 W/SE
54061
200
70
3.0
>90
16000
6000
80
39
20
5
200
Any
GZY9.5
Yes
1
1
HMI 250 W/SE
54062
270
50
5.0
>90
16200
6000
84
35
12
5
250
p 45
FaX1.5
Yes
2
1,60
HMI 400 W/SE
54137
400
70
6.9
>90
33000
6000
110
60
23
6
650
Any
GZ9.5
Yes
3
90
HMI 575 W/SEL XS
54063
575
95
7.0
>90
49000
6000
145
70
30
7
1000
Any
G22
Yes
4
90,161
HMI 700 W/SE XS
54310
700
95
9.0
>90
55000
6000
145
70
30
7
750
Any
G22
Yes
4
161
HMI 1200 W/SEL XS
54067
1200
100
13.8
>90
110000
6000
200
107
42
10
1000
Any
G38
Yes
4
90,161
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HMI® SINGLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
225
071_DOD_print.qxd
12/12/07
3:02 PM
Page 226
HMI® METAL HALIDE
1
2
HMI® SINGLE-ENDED
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMI 2500 W/SE XS
54070
2500
115
25.6
>90
240000
6000
225
127
60
14
500
Any
G38
Yes
1
90,161
HMI 4000 W/SE XS
54321
4000
200
24.0
>90
380000
6000
250
142
75
20
500
Any
G38
Yes
1
90,161
HMI 6000 W/SE XS
54099
6000
123
55.0
>90
600000
6000
360
210
75
23
500
s 135
GX38
Yes
2
58,90,139,161
HMI 12000 W/SE XS
54113
12000
160
84.0
>90
1150000
6000
450
255
100
27
300
s 135
GX38
Yes
2
58,90,139,161
HMI 12000W/SE/GX51
54357
12000
160
84.0
>90
1150000
6000
460
260
100
27
300
s 135
GX51
Yes
2
58,90,161
HMI 18000 W/SE/GX51
54289
18000
225
88.0
>90
1600000
6000
495
260
100
44
300
s 135
GX51
Yes
2
58,90,161
HMI® SINGLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
For more complete product information visit www.sylvania.com
226
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 227
HMI® METAL HALIDE
1
2
3
4
HMI® DOUBLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l1 max (mm)
Length l2 max (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMI 575 W/DXS
54313
575
95
7.0
>90
49000
6000
135
115
21
7
1000
Any
SFc10-4
Yes
1
55,90,161
HMI 575 W/GS
54098
575
95
7.0
>90
49000
6000
135
115
21
7
1000
Any
SFc10-4
Yes
1
52,90
HMI 1200 W/DXS
55139
1200
100
13.8
>90
110000
6000
220
180
27
10
750
Any
SFc15.5
Yes
2
55,90,161
HMI 1200 W/GS
54066
1200
100
13.8
>90
110000
6000
220
180
27
10
750
Any
SFc15.5
Yes
2
52,90
HMI 2500 W/DXS
54265
2500
115
25.6
>90
240000
6000
355
290
31.5
14
500
p 30
SFa21
Yes
4
55,60,161
HMI 2500 W/S XS
54068
2500
115
25.6
>90
240000
6000
210
150
31.5
14
500
p 30
SFa21
Yes
4
43,60,90,161,201
HMI 4000 W
54071
4000
200
24.0
>90
380000
6000
405
340
36
34
500
p 15
SFa21
Yes
4
60,90,219
HMI 4000 W/DXS
54314
4000
200
24.0
>90
380000
6000
405
340
36
34
500
p 15
SFa21
Yes
4
55,60,90,161,219
HMI 1200 W/S XS
54088
1200
100
13.8
>90
110000
6000
135
115
21
7
750
Any
SFc10-4
Yes
3
43,90,161,196,201
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HMI® DOUBLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l1 max (mm)
Length l2 max (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
227
071_DOD_print.qxd
12/12/07
3:02 PM
Page 228
HMI® METAL HALIDE
2
HMI® DOUBLE-ENDED
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l1 max (mm)
Length l2 max (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMI 6000 W
54073
6000
123
55.0
>90
570000
6000
450
HMI 6000 W/DXS
54315
6000
123
55.0
>90
570000
6000
450
HMI 12000 W/DXS
54316
12000
160
84.0
>90
1150000
6000
470
HMI 12000 W/XS
54074
12000
160
84.0
>90
1150000
6000
470
54
21
500
p 15
S25.5
Yes
2
60,90
54
21
500
p 15
S25.5
Yes
2
55,60,90,161
64
25
500
p 15
S30
Yes
2
55,60,90,161
64
25
500
p 15
S30
Yes
2
60,90,161
HMI® DOUBLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l1 max (mm)
Length l2 max (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMI 18000 W/DXS
54317
18000
225
88.0
>90
1700000
6000
500
70
44
300
p 15
S30
Yes
2
55,60,90,161,219
For more complete product information visit www.sylvania.com
228
Symbols/Footnotes on page 279-287
071_DOD_print.qxd
12/12/07
3:02 PM
Page 229
HTI® METAL HALIDE
1
2
3
4
5
6
7
HTI® SINGLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI S 35/12
69000
35
85
2.5
>90
3200
6500
4250
79.5
27.1
4.2
3000
p 10
P32d-2
Yes
1
60
HTI 150 W
54078
150
90
1.8
>70
9500
5000
6500
46
30
5.0
750
Any
GY9.5 Bipin Prefocus
No
2
2,90
HTI 152 W
54079
150
95
1.8
>90
9500
4200
5000
48
30
6.75
2000
Any
GY9.5 Bipin Prefocus
No
3
90
HTI 405 W/SE XS
54139
400
55
7.3
>90
28000
40000
5800
80
36.5
3.0
500
p 45
GY9.5 Bipin Prefocus
No
4
1,10,48,53,60,161
HTI 600 W/SE
54087
600
95
7.7
>90
48000
25000
5300
84
35
5.5
300
p 45
FaX1.5
Yes
5
10,37,60,90,112
HTI 700 W/SE/75
54329
700
70
10
>80
59000
HTI 705 W/SE XS
54130
700
70
10
>80
59000
7500
85
39
4
500
p 45
FaX1.5
Yes
5
10,60,161
5500
85
39
4
500
p 45
GY9.5 Bipin Prefocus
No
4
10,60,161
HTI 1200 W/SE XS
54141
1200
100
13.8
>90
99000
26000
5400
135
59
7
600
s 135
GY22
Yes
6
10,19,58,90,161
HTI 1800W/SE XS
54770
1800
100
20
>90
155000
35000
5600
135
59
7
750
s 135
GY22
Yes
6
10,19,58,90,161
HTI 2500 W/SE XS
54142
2500
115
25.6
>90
240000
30000
6000
180
85
14
600
s 135
G22+Cable
Yes
7
28,58,90,161
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HTI® SINGLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
229
071_DOD_print.qxd
12/12/07
3:02 PM
Page 230
HTI® METAL HALIDE
1
HTI® SHARXS® DOUBLE-ENDED
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 400W/D3/75 SHARXS
54241
400
49
8.5
>80
26000
55000
7500
136
57.5
18
3
1000
Any
SFc10-4
Yes
1
90,161,166,167
HTI 400W/D3/75 SHARXS BULK
54280
400
49
8.5
>80
26000
55000
7500
136
57.5
18
3
1000
Any
SFc10-4
Yes
1
90,161,166,167,290
HTI 575W/D4/60 SHARXS
54296
575
69
8.3
>85
49000
49000
6000
136
57.5
20
4
750
Any
SFc10-4
yes
1
90,161,166,167
HTI 700W/D4/60 SHARXS
54282
700
70
10.0/11.0
>80
59000
60000
6000
136
57.5
20
4
750
Any
SFc10-4
Yes
1
90,161,166,167
HTI 700W/D4/60 SHARXS BULK
54283
700
70
10.0/11.0
>80
59000
60000
6000
136
57.5
20
4
750
Any
SFc10-4
Yes
1
90,161,166,167,290
HTI® SHARXS® DOUBLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 575W/D4/75 SHARXS
54270
575
64
9
>80
44000
49000
7500
136
57.5
20.5
4
750
Any
SFc10-4
yes
1
90,161,166,167
For more complete product information visit www.sylvania.com
230
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 231
HTI® METAL HALIDE
1
HTI® SHARXS® DOUBLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 700W/D4/75 SHARXS
54242
700
70
10.0/11.0
>80
59000
60000
7500
136
57.5
20.5
4
750
Any
SFc10-4
Yes
1
90,161,166,167
HTI 700W/D4/75 SHARXS BULK
54281
700
70
10.0/11.0
>80
59000
60000
7500
136
57.5
20.5
4
750
Any
SFc10-4
Yes
1
90,161,166,167,290
HTI 1200W/D7/60 SHARXS
54268
1200
100
12.7/13.8
>90
110000
41000
6000
136
57.5
21
7
750
Any
SFc10-4
Yes
1
90,161,166,167,196
HTI 1200W/D7/75 SHARXS
54269
1200
100
12.7/13.8
>80
110000
41000
7500
136
57.5
21
7
750
Any
SFc10-4
Yes
1
90,161,166,167
HTI 1500W/D7/60 SHARXS
54319
1500
110
13.6
>90
155000
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HTI® SHARXS® DOUBLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 1200W/D7/60 SHARXS BULK
54202
1200
100
12.7/13.8
>90
110000
41000
6000
136
57.5
21
7
750
Any
SFc10-4
Yes
1
90,161,166,167,196,290
For more complete product information visit www.sylvania.com
6000
136
57.5
25
7
750
Any
SFc10-4
Yes
1
90,161,166,167
Symbols/Footnotes on page 275-281
231
071_DOD_print.qxd
12/12/07
3:02 PM
Page 232
HTI® METAL HALIDE
1
HTI® BABY SHARXS® DOUBLE-ENDED
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 250W/D5/80 BABY SHARXS
54297
250
90
3.2
>80
18000
8000
93
35
16
5
3000
Any
SFc10-4
Yes
1
1,161,167,206
HTI 300W/D5/57 BABY SHARXS
54298
300
80
4.3
>85
20000
5700
93
35
16
5.5
3000
Any
SFc10-4
Yes
1
1,161,167,206
HTI 300W/D5/65 BABY SHARXS
54299
300
80
4.3
>85
22000
6500
93
35
16
5.5
750
Any
SFc10-4
Yes
1
1,161,167,206
HTI® BABY SHARXS® DOUBLE-ENDED
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 400W/D5/60 BABY SHARXS
54300
400
95
7.0
>85
33000
6000
93
35
18
5.5
750
Any
SFc10-4
Yes
1
1,161,167,206
For more complete product information visit www.sylvania.com
232
HTI 575W/D5/56 BABY SHARXS
54359
575
95
7.0
>85
43000
5600
93
35
18
5
500
Any
SFc10-4
Yes
1
1,161,167,206
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 233
HTI® METAL HALIDE
1
2
3
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HTI® DOUBLE-ENDED - OTHER
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 300 W/DX
54143
300
100
3.6
90
22000
20000
6500
92
70
16
5.5
750
p 45
SFc10-4
Yes
1
60,90
For more complete product information visit www.sylvania.com
HTI 2500 W/DEL
54399
2500
115
26.0
90
270000
6000
295
108
31.5
25
2000
p 45
Special
Yes
2
60,90
HTI 4000 W/DE
54133
4000
115
39.0
90
360000
35000
6300
270
140
40
15
500
p 30
S25.5
Yes
3
60,90
Symbols/Footnotes on page 275-281
233
071_DOD_print.qxd
12/12/07
3:02 PM
Page 234
HTI® METAL HALIDE
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
2
HTI® WITH DICHROIC REFLECTOR
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Color Temp (K)
Length l max (mm)
Working Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Hot Restart
Fig No
Symbols & Footnotes
HTI 250 W/22
54080
270
45
6.0
70
5600
73
22
67
2.5
250
P 20
Yes
1
1,60
For more complete product information visit www.sylvania.com
234
HTI 250 W/32
54081
270
45
6.0
70
5600
73
32
67
2.5
250
P 20
Yes
1
1,60,63
HTI 250 W/32C
54089
270
45
6.0
70
5600
73
32
67
2.5
250
P 20
Yes
2
60,90
HTI 400 W/24
54083
400
55
7.3
70
5600
73
24
67
4.0
250
P 20
Yes
2
1,60
HTI 403 W/24
54104
400
55
7.3
70
5600
73
24
67
4.0
750
P 20
Yes
2
1,60
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 235
HSR® METAL HALIDE
1
2
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HSR® WITH OUTER JACKET
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HSR 400/60
54102
400
67
6.9
>85
33000
20000
6000
110
62
23
5
650
Any
GX9.5
No
1
90
For more complete product information visit www.sylvania.com
HSR 575/60
54115
575
95
7.0
>85
49000
10000
6000
125
65
30
7
1000
Any
GX9.5
No
1
90
HSR 575/72
54116
575
95
7.0
>85
49000
10000
7200
125
65
30
7
1000
Any
GX9.5
No
1
90
HSR 700/60
54107
700
72
11.0
>85
58000
10000
6000
155
75
30
8
1000
Any
G22
NO
2
90
HSR 1200/60
54168
1200
100
13.8
>85
110000
20000
6000
175
85
40
10
1000
Any
G22
No
2
90
Symbols/Footnotes on page 275-281
235
071_DOD_print.qxd
12/12/07
3:02 PM
Page 236
HSD® METAL HALIDE
1
2
3
HSD® 4ARXS METAL HALIDE
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HSD 150W/70 4ARXS
54311
150
97
1.8
>85
12000
7000
105
56
20
5.5
3000
Any
G12
No
1
90,161
HSD 150W/UL/75 4ARXS
54312
150
97
1.8
>85
11000
7500
105
56
20
5.5
6000
Any
G12
No
1
90,161
HSD 200W/60 4ARXS
54167
200
70
3.3
>80
13000
6000
108
55
23
5
2000
Any
GY9.5
No
2
90,161,191
HSD 250W/60 4ARXS
54170
250
90
3.1
>85
17000
6000
108
55
23
5
2000
Any
GY9.5
No
2
90,161
HSD 250W/80 4ARXS
54243
250
95
3.2
>85
17000
8000
108
55
23
5
3000
Any
GY9.5
No
2
90,161
HSD 575W/72 4ARXS
54129
575
88
7.4
>85
45000
7200
135
65
30
7
3000
Any
GX9.5
No
3
90,161
HSD 250W/UL/75 4ARXS
54288
250
90
3.1
>85
15000
7500
108
55
23
5
6000
Any
GY9.5
No
2
90,161
HSD 575W/60 4ARXS
54271
575
88
7.4
>85
45000
6000
135
65
30
7
3000
Any
GX9.5
No
3
90,161
HSD® 4ARXS METAL HALIDE
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
CRI
Lumens (lm)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
For more complete product information visit www.sylvania.com
236
HSD 575W/UL/75 4ARXS
54287
575
88
7.4
>80
43000
7500
135
65
30
7
6000
Any
GX9.5
No
3
90,161
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 237
XBO®<=450W XENON SHORT ARC
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
3
XBO 75 W/2
69231
75
14
DC
5.4
XBO 75 W/2 OFR
69232
75
14
DC
5.4
XBO 100 W OFR
69233
100
14
DC
7.0
1000
100
40000
0.25 x 0.5
90
82
43
10
400
400
s 105
0
SFa9-2
SFa7.5-2
1
38,58,129,157,179
1000
100
40000
0.25 x 0.5
90
82
43
10
400
400
s 105
0
SFa7.5-2
SFa7.5-2
1
56,58,129,157,179
1900
270
31000
0.4 x 0.8
90
82
44.5
11
500
For more complete product information visit www.sylvania.com
s 105
Required
SFa9-2
SFa7.5-2
1
56,58,129,157,179
XBO R 100 W/45 OFR
69197
100
13
DC
7.0
XBO R 100 W/45C OFR
69191
100
13
DC
7.0
0.4 x 0.9
83
75
0
67
0.4 x .09
83
75
0
67
500
p 15
Required
500
p 15
Required
2
56,60,129,146,157,
168,190
3
44,56,60,129,157,190
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Symbols/Footnotes on page 275-281
237
071_DOD_print.qxd
12/12/07
3:02 PM
Page 238
XBO®<=450W XENON SHORT ARC
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO R 101 W/45C OFR
69190
100
13
DC
7.0
0
83
75
0
67
500
p 15
Required
1
44,56,60,129,157,
190,202
For more complete product information visit www.sylvania.com
238
XBO 150 W/1
69234
150
20
DC
7.5
XBO 150 W/1 OFR
69235
150
20
DC
7.5
XBO 150 W/4
69238
150
20
DC
7.5
XBO 150 W/CR OFR
69237
150
18
DC
8.5
3000
300
15000
0.5 x 2.2
150
127
57
20
1200
3000
300
15000
0.5 x 2.2
150
127
57
20
1200
3000
300
15000
0.5 x 2.2
150
127
57
20
1200
s 15
Required
SFc12-4
SFcX12-4
2
39,58,129,157,179,212
s 15
Required
SFc12-4
SFcX12-4
2
56,58,129,157,179,212
s 15
Required
SFc12-4
SFcX12.4
2
40,58,129,157,179
2900
290
20000
0.5 x 1.6
150
127
57
20
3000
1200
s15 p15
Required
SFc12-4
SFcX12-4
2
56,58,60,68,129,157,
179,213
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 239
XBO®<=450W XENON SHORT ARC
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 150 W/S
69236
150
20
DC
7.5
2200
220
18000
0.5 x 1.9
117
96
47.5
20
1000
800
s15 p15
Required
SFa12-11
SFa12-11
1
43,58,60,68,129,157,179
For more complete product information visit www.sylvania.com
3
4
5
XBO R 180 W/45/OFR
69186
180
14
DC
12.0
XBO R 180 W/45C OFR
69183
180
14
DC
12.0
XBO R 181 W/45C OFR
69184
180
14
DC
12.0
XBO R 300 W/60C OFR
69167
300
17
DC
16.0
14 - 19
0
90
75
0
67
500
0
90
75
0
67
500
0
90
75
0
67
500
0
62
30
60
82.5
p 15
Required
p 15
Required
p 15
Required
2
36,56,60,129,157,190
3
44,56,60,129,157,190
4
5
44,56,60,129,157,190,202 44,56,60,129,157,165
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
1000
p20
Required
Symbols/Footnotes on page 275-281
239
071_DOD_print.qxd
12/12/07
3:02 PM
Page 240
XBO®<=450W XENON SHORT ARC
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 450 W
69241
450
17
DC
25.0
17-30
13000
1300
35000
0.9 x 2.7
260
95.5
29
2000
XBO 450 W OFR
69245
450
17
DC
25.0
17-30
13000
1300
35000
0.9 x 2.7
260
212
95.5
29
2000
s 30
Required
SFa20-8
SFa20-10
1
41,42,58,129,157,179
s 30
Required
SFa20-8
SFa20-10
1
56,58,129,157,179
For more complete product information visit www.sylvania.com
240
XBO 450 W/1
69242
450
17
DC
25.0
17-30
13000
1300
45000
0.7 x 2.2
260
212
95.5
29
800
800
s 100
Required
SFa20-8
SFa20-10
1
58,129,157,179
XBO 450 W/2 OFR
69243
450
17
DC
25.0
17-30
13000
1300
35000
0.9 X 2.7
177
0
79
29
2000
XBO 450 W/4
69244
450
17
DC
25.0
17-30
13000
1300
35000
0.9 x 2.7
260
212
95.5
29
2000
s 30
Required
SK19/36
SK19/36
2
56,58,129,157,179
s 30
Required
SFa20-8
SFa20-10
1
40,58,129,157,179
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 241
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 500 W/H OFR
69257
500
17
DC
28
17-30
14500
1450
40000
0.9 x 2.5
190
165
75
35
2000
s30 p30
Required
Required
SFa16-8
SFa15-10
1
45,56,58,60,109,129,
157,179
For more complete product information visit www.sylvania.com
3
4
5
XBO 700 W/HS OFR
69260
700
18
DC
37
30-45
20000
2000
40000
1.1 x 2.9
235
205
95
40
1500
s20 p20
Required
XBO 900 W OFR
69261
900
19
DC
45
30-53
30000
3000
50000
1.1 x 3.3
325
277
123
40
2400
s 30
Required
XBO 1000 W/HS OFR
69263
1000
19
DC
50
30-55
32000
3000
60000
1.1 x 2.8
235
205
95
40
2000
s20 p20
Required
XBO 1000 W/HSC OFR
69264
1000
19
DC
50
30-55
32000
3000
60000
1.1 x 2.8
236
222
95
40
2000
s20 p20
Required
SFa27-11
SFcX27-8
2
43,45,56,58,60,129,
157,179
SFa25-10
SFa25-12
3
56,58,129,157,179
SFa27-11
SFcX27-8
4
43,45,56,58,60,129,
157,179
SK27/50
SFcX27-8
5
43,44,45,56,58,60,129,
157,179
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Symbols/Footnotes on page 275-281
241
071_DOD_print.qxd
12/12/07
3:02 PM
Page 242
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 1000 W/HTP OFR
69265
1000
21
DC
45
30-55
35000
3200
45000
1.0 x 4.0
330
277
123
46
2400
s30 p30
Required
Required
SFa25-14
SFc25-14
1
45,51,56,58,60,109,129,
157,179
For more complete product information visit www.sylvania.com
242
3
4
5
XBO 1600 W/HS OFR
69268
1550
23
DC
65
50-75
70000
5500
70000
1.0 x 3.2
235
205
95
46
2000
s20 p20
Required
XBO 1600 W/HSC OFR
69269
1550
23
DC
65
50-70
70000
5500
70000
1.0 x 3.2
236
222
95
46
2000
s20 p20
Required
XBO 1600 W OFR
69266
1600
24
DC
65
45-75
60000
6000
65000
1.4 x 4.0
370
322
142.5
52
2400
s 30
Required
XBO 1600 W/CA OFR
69267
1600
24
DC
65
45-75
60000
6000
65000
1.4 x 4.0
370
322
143
52
2400
s 30
Required
SFa27-11
SFcX27-8
2
43,45,56,58,60,129,
157,179
SK27/50
SFcX27-8
3
43,44,45,56,58,60,129,
157,179
SFa27-10
SFa27-12
4
56,58,129,157,179
SFaX27-10
SFa27-12
5
47,56,58,129,157,179
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 243
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 2000 W/DTP OFR
69155
2000
25
DC
80
50-85
80000
7500
75000
1.3 x 4.0
403
354
160
52
2400
s30 p30
Required
Required
SFa 25-14
SFc25-14
1
51,56,58,60,109,129,
157,179,279
For more complete product information visit www.sylvania.com
3
XBO 2000 W/H CL OFR
69470
2000
28
DC
70
50-85
80000
7500
80000
1.3 x 4.8
370
322
142.5
46
2400
s30 p30
Required
XBO 2000 W/H OFR
69385
2000
28
DC
70
50-85
80000
7500
80000
1.3 x 4.8
370
322
142.5
52
2400
s30 p30
Required
SFaX27-10
SFaX27-12
2
45,56,58,60,129,157,
179,281
SFaX27-10
SFaX27-12
3
45,56,58,60,129,157,
179,193
4
XBO 2000 W/H XL OFR
69477
2000
27
DC
70
50-85
80000
7500
75000
1.3 x 4.8
365
320
142.5
52
3500
s30 p30
Required
Required
SFaX27-10
SFaX27-12
4
45,56,58,60,129,157,
179,280
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 2000 W/HCC OFR
69384
2000
28
DC
70
50-85
80000
7500
80000
1.3 x 4.8
370
322
142.5
52
2400
s30 p30
Required
SFaX27-10
SFaX27-12
3
44,45,56,58,60,129,157,
179,195
Symbols/Footnotes on page 275-281
243
071_DOD_print.qxd
12/12/07
3:02 PM
Page 244
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 2000 W/HPS OFR
69486
2000
25
DC
80
60-90
75000
8000
160000
1.3 x 3.2
332
295
128
46
2400
s15 p15
Required
XBO 2000 W/HS OFR
69270
2000
24
DC
80
50-85
80000
7500
80000
1.3 x 4.0
342
302
145
60
2400
s30 p30
Required
SFaX30-14/68
SFc30-20/50
1
56,58,60,129,157,179,
282,283
SFaX27-9.5
SFa27-7.9
2
43,45,56,58,60,129,
157,179
For more complete product information visit www.sylvania.com
244
3
4
XBO 2000 W/HTP OFR
69247
2000
27
DC
70
50-85
80000
7500
75000
1.3 x 4.8
375
322
142.5
52
2400
s30 p30
Required
Required
SFa25-14
SFc25-14
3
45,51,56,58,60,109,
129,157,179
XBO 2000 W/SHSC OFR
69256
2000
27
DC
70
50-85
80000
7500
80000
1.3 x 4.0
236
222
95
46
2000
s20 p20
Required
SK27/50
SFcX27-8
4
49,56,58,60,129,157,179
XBO 2001 W/HTP OFR
69310
2000
25
DC
80
50-85
80000
7500
75000
1.3 x 4.0
375
322
142.5
60
2400
s30 p30
Required
Required
SFa25-14
SFc25-14
3
45,51,56,58,60,109,129,
157,179
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 245
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
3
XBO 2500 W OFR
69248
2500
29
DC
85
60-95
100000
9500
61000
1.5 x 6.0
428
382
167.5
60
2000
s 30
XBO 2500 W/HS OFR
69249
2500
28
DC
90
70-100
100000
10000
80000
1.5 x 4.5
342
302
145
60
1500
s30 p20
Required
SFaX27-13
SFaX27-14
1
56,58,129,157,179
SFaX27-9.5
SFa27-7.9
2
43,45,56,58,60,129,
157,179
For more complete product information visit www.sylvania.com
4
XBO 2500 W/HTP OFR
69160
2500
28
DC
90
70-100
100000
9500
60000
1.5 x 6.0
398
357
165
60
1500
s30 p30
Required
Required
SFa27-14
SFc27-14
3
45,51,56,58,60,109,
129,157,179
5
XBO 3000 W/DHP OFR
69480
2600
29
DC
90
80-110
140000
13500
180000
1,3 x 3,5
340
294
123
55
1500
s15 p15
Required
SFaX27-14/80
SFc27-16/45
4
56,58,60,129,157,179,
279,282
XBO 3000 W/DHS OFR
69462
3000
29
DC
110
60-120
130000
12000
105000
1.7 x 4.0
340
300
145
55
1500
s30 p30
Required
Required
SFaX 27-9.5
SFa 27-7.9
5
43,45,56,58,60,129,157,
179,279
Symbols/Footnotes on page 275-281
245
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
071_DOD_print.qxd
12/12/07
3:02 PM
Page 246
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 3000 W/DTP OFR
69154
3000
27
DC
110
60-120
130000
15000
120000
1.5 x 4.0
403
352
160
60
1500
s30 p30
Required
Required
SFc27-14
SFa27-14
1
51,56,129,157,179,279
For more complete product information visit www.sylvania.com
246
3
XBO 3000 W/H CL OFR
69475
3000
30
DC
100
60-110
130000
12000
85000
1.7 x 5.0
428
382
167.5
55
1500
s30 p30
Required
Required
SFaX27-13
SFa27-14
2
45,56,58,60,129,157,
179,281
4
XBO 3000 W/H OFR
69251
3000
30
DC
100
60-110
130000
12000
85000
1.7 x 5.0
428
382
167.5
66
1500
s30 p30
Required
Required
SFaX27-13
SFa27-14
3
45,56,58,60,109,129,
157,179
5
XBO 3000 W/H XL OFR
69478
3000
30
DC
100
70-110
130000
12000
90000
1.7 x 5.0
423
380
167.5
60
2200
s30 p30
Required
Required
SFaX27-13
SFa27-14
4
45,56,58,60,129,157,
179,280
XBO 3000 W/HPS OFR
69487
3000
29
DC
105
70-110
140000
13500
180000
1.3 x 3.5
332
295
128
55
1000
s15 p15
Required
SFaX30-14/68
SFc30-20/50
5
56,58,60,129,157,179,
282,283
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 247
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 3000 W/HS CL OFR
69153
3000
29
DC
100
60-110
130000
12000
90000
1.7 x 5.0
342
302
145
55
1500
s30 p30
Required
Required
SFaX27-9.5
SFa27-7.9
1
56,58,60,129,157,
179,281
For more complete product information visit www.sylvania.com
XBO 3000 W/HS OFR
69250
3000
29
DC
100
60-110
130000
12000
90000
1.7 x 5.0
342
302
145
60
1500
s30 p30
Required
Required
SFaX27-9.5
SFa27-7.9
2
43,45,56,58,60,109,
129,157,179
3
XBO 3000 W/HS XL OFR
69479
3000
30
DC
100
70-110
130000
12000
90000
1.7 x 5.0
340
300
145
60
2200
s30 p30
Required
Required
SFaX27-9.5
SFa27-7.9
3
43,45,56,58,60,129,
157,179,280
4
XBO 3000 W/HSLA OFR
69390
3000
29
DC
110
60-120
130000
12000
105000
1.7 x 4.0
342
302
145
54
1500
s30 p30
Required
Required
SFaX 27-9.5
SFa 27-7.9
2
43,45,56,58,60,109,
129,157,179,210
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 3000 W/HTP OFR
69252
3000
29
DC
100
60-110
130000
12000
85000
1.7 x 5.0
405
357
162.5
66
1500
s30 p30
Required
SFa27-14
SFc27-14
4
45,51,56,58,60,129,
157,179
Symbols/Footnotes on page 275-281
247
071_DOD_print.qxd
12/12/07
3:02 PM
Page 248
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 4000 W/HS CL OFR
69394
4000
28
DC
135
80-150
155000
17000
90000
1.9 x 6.0
410
370
171
60
1000
s20 p20
Required
Required
SFaX30-9.5
SFa30-7.9
1
56,58,60,129,157,179,
281
For more complete product information visit www.sylvania.com
248
3
XBO 4000 W/HS OFR
69254
4000
28
DC
135
80-150
155000
17000
90000
1.9 x 6.0
410
370
171
70
1000
s20 p20
Required
Required
SFaX30-9.5
SFa30-7.9
2
43,45,56,58,60,109,129,
157,179
4
XBO 4000 W/HS XL OFR
69474
4000
27
DC
135
80-150
155000
17000
90000
1.9 x 6.0
408
368
171
70
1500
s20p20
Required
Required
SFaX30-9.5
SFa30-7.9
3
43,45,56,58,60,129,
157,179,280
5
XBO 4000 W/HTP OFR
69296
4000
30
DC
130
100-140
155000
16000
90000
1.9 x 6.0
433
382
167.5
70
1000
s20 p20
Required
XBO 4000 W/DHP OFR
69481
4200
34
DC
125
100-130
170000
17000
140000
1.6 x 5.0
340
294
123
55
700
s15 p15
Required
SFa27-14
SFc27-14
4
45,51,56,58,60,129,
157,179
SFaX27-14/80
SFc27-16/45
5
56,58,60,129,157,179,
279,282
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 249
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 4200 W/CA OFR
69294
4200
29
DC
140
80-160
190000
20000
100000
2.1 x 5.7
428
382
167.5
70
1000
s 15
Required
SFaX27-13
SFaX27-14
1
47,56,58,129,157,
179,220
For more complete product information visit www.sylvania.com
3
XBO 4200 W/GS OFR
69350
4200
29
DC
140
80-160
190000
20000
100000
2.1 x 5.7
428
382
167.5
60
1000
s 15
Required
Required
SFaX27-13
SFaX27-14
1
52,56,58,109,129,
157,179
XBO 4200 W/HPS OFR
69488
4200
35
DC
120
80-130
170000
17000
160000
1.5 x 4.5
332
295
128
55
500
s15 p15
Required
SFaX30-14/68
SFc30-20/50
2
56,58,60,129,157,179,
282,283
4
XBO 4500 W/DHP OFR
69463
4500
30
DC
145
80-150
190000
22000
115000
1.9 x 5.0
408
368
171
60
1000
s15 p15
Required
Required
SFaX30-9.5
SFa30-7.9
3
56,58,60,129,157,
179,279,282
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 4500 W/DTP OFR
69459
4500
32
DC
145
80-150
190000
25000
115000
1.9 x 5.0
433
384
165
60
1000
s15 p15
Required
Required
SFcX27-14
SFa27-14
4
51,56,58,60,129,157,
179,279
Symbols/Footnotes on page 275-281
249
071_DOD_print.qxd
12/12/07
3:02 PM
Page 250
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 4500 W/HS OFR
69359
4500
32
DC
135
80-150
190000
22000
120000
1.9 x 6.0
410
370
171
70
1000
s15 p15
Required
Required
SFa30-7.9
SFaX30-9.5
1
43,45,56,58,60,109,129,
157,179
For more complete product information visit www.sylvania.com
250
XBO 4500 W/HSLA OFR
69389
4500
30
DC
145
80-150
160000
22000
115001
1.9 x 5.0
410
370
171
60
1000
s15 p15
Required
Required
SFaX30-9.5
SFa30-7.9
1
43,45,56,58,60,109,129,
157,179,210
XBO 4500 W/HTP OFR
69360
4500
32
DC
135
80-150
190000
22000
105000
1.9 x 6.0
433
382
171
70
1000
s15 p15
Required
Required
SFa27-14
SFc27-14
2
45,51,56,58,109,129,
157,179
XBO 5000 W/H OFR
69315
5000
35
DC
140
100-150
225000
27000
95000
2.2 x 6.5
433
382
168
70
1000
s15 p15
Required
Required
SFaX27-13
SFaX27-14
1
45,56,58,60,109,129,
157,179
XBO 5000 W/HTP OFR
69336
5000
34
DC
140
100-150
225000
27000
95000
2.2 x 6.5
433
382
165
70
1000
s15 p15
Required
Required
SFa27-14
SFc27-14
2
45,51,56,58,60,109,129,
157,179
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:02 PM
Page 251
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 6000 W/DHP OFR
69476
6000
35
DC
170
140-175
280000
30000
160000
1.9 x 6.0
431
391
170.5
70
600
s15 p15
Required
Required
SFaX30-9.5
SFa30-7.9
1
56,58,60,129,157,179,
279,282
For more complete product information visit www.sylvania.com
XBO 6000 W/DTP OFR
69460
6000
39
DC
155
140-175
270000
33000
130000
1.9 x 7.0
433
386
165
70
600
s15 p15
Required
Required
SFc27-14
SFa27-14
2
51,56,58,60,109,129,157,
179,279
3
XBO 6000 W/HS OFR
69339
6000
37
DC
160
110 - 165
280000
40000
105000
2.0 x 7.5
433
393
170.5
78
750
s15 p15
Required
Required
SFaX30-9.5
SFa30-7.9
3
43,45,56,58,60,109,129,
157,179
4
XBO 6000 W/HSLA OFR
69386
6000
35
DC
170
140-175
280000
30000
160000
1.9 x 6.0
433
393
170.5
70
600
s15 p15
Required
Required
SFaX30-9.5
SFa30-7.9
3
43,45,56,58,60,109,129,
157,179,210
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 6000 W/HTP OFR
69340
6000
37
DC
160
110 - 165
280000
40000
105000
2.0 x 7.5
433
382
165
78
750
s15 p15
Required
Required
SFaX27-14
SFc27-14
4
43,45,51,56,58,60,109,
129,157,179
Symbols/Footnotes on page 275-281
251
071_DOD_print.qxd
12/12/07
3:03 PM
Page 252
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
XBO 6500 W/DHP OFR
69461
6500
38
DC
170
140-175
300000
32000
160000
2.0 x 6.3
431
391
170.5
70
500
s15 p15
Required
Required
SFaX30-9.5
SFa30-7.9
1
56,58,60,129,157,179,279,282
For more complete product information visit www.sylvania.com
252
XBO 6500 W/HSLA OFR
69489
6500
38
DC
170
140-175
300000
32000
160000
2.0 x 6.3
433
393
170.5
70
500
s15 p15
Required
Required
SFaX30-9.5
SFa30-7.9
2
43,45,56,58,60,109,129,157,
179,210
XBO 7000 W/HS OFR
69295
7000
42
DC
160
110-165
350000
35000
100000
2.0 x 7.5
433
393
170.5
78
650
s15 p15
Required
Required
SFaX30-9.5
SFa30-8.0
2
43,45,56,58,60,109,129,157,179
XBO 8000 W/HS OFR
69351
8000
45
DC
175
150-180
400000
40000
110000
2.5 x 10.5
433
393
170.5
90
500
s 15, p15
Required
Required
SFaX 30-9.5
SFa 30-7.9
2
43,45,56,58,60,109,129,157,179
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 253
XSTAGE™ XENON SHORT ARC ENTERTAINMENT
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Warranty
Operating Position
Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
Xstage 2000W OFR
69482
2000
23
DC
90
70-110
80000
9000
170000
1.2x2.7
300
262
120
46.5
1000
any
Required
Xstage 3000W OFR
69483
3000
30
DC
100
70-110
140000
13500
200000
1.3x3.5
300
262
120
55
1000
any
Required
Xstage 4000W OFR
69484
4000
30
DC
130
80-135
150000
17000
120000
1.9x5.0
315
277
120
60
1000
any
Required
Xstage 7000W OFR
69485
7000
40
DC
160
110-165
330000
33000
120000
2.0x7.0
405
354
162.5
70
1000
any
Required
SFaX27-9.5
SFc28-27
1
56,129,157,179
SFaX27-9.6
SFc28-28
1
56,129,157,179
SFaX27-9.7
SFc28-29
1
56,129,157,179
SFaX27-9.8
SFc28-30
2
56,129,157,179
For more complete product information visit www.sylvania.com
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Symbols/Footnotes on page 275-281
253
071_DOD_print.qxd
12/12/07
3:03 PM
Page 254
HBO® MERCURY SHORT ARC
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area – w x h (mm)
Luminous Efficacy (lm/W)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
HBO 50 W AC L1
69213
50
42
AC
1.3
2000
230
30000
0.3 x 1.0
40
53
47
22
8.5
100
s 45
Convection
SFa6-2
SFa6-2
1
58
For more complete product information visit www.sylvania.com
254
3
HBO 50 W AC L2
69214
50
37
AC
1.45
2000
230
30000
0.3 x 1.0
40
53
47
22
8.5
100
s 45
Convection
SFa6-2
SFa6-2
1
58
HBO 50 W/3
69215
50
23
DC
2.3
1300
150
90000
0.2 x 0.35
26
53
47
22
9
200
s 45
Convection
SFa6-2
SFa8-2
2
58
HBO 100 W/2
69217
100
20
DC
5.0
2200
260
170000
0.25 x 0.25
22
90
82
43
10
200
s 90
Convection
SFa7.5-2
SFa9-2
3
58
HBO 103 W/2
69182
100
23
DC
4.44
2550
270.0
150000
0.25 x 0.25
30
90
82
43
10
300
s 90
Convection
SFa7.5-2
SFa9-2
3
58,222
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 255
HBO® MERCURY SHORT ARC
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area – w x h (mm)
Luminous Efficacy (lm/W)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
HBO R 103 W/45
69311
100
23
DC
4.3
81.50
67
300
p 20
Convection
Pin
Pin
1
60,190,223
For more complete product information visit www.sylvania.com
HBO 200 W/2 L1
69198
200
61
DC or AC
HBO 200 W/2 L2
69222
200
53
DC or AC
HBO 200 W/2 TM L2
69223
200
47
DC or AC
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
400
s 45
Convection
SFc10-4
SFc10-4
2
58,86,226,227
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
400
s 45
Convection
SFc10-4
SFc10-4
2
58,86,226,227
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
200
s 45
Convection
8-32 UNC-3A
8-32 UNC-3A
2
58,87
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 200 W/4
69224
200
61
AC
3.6
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
200
s 45
Convection
SFc10-4
SFc10-4
2
58,225
Symbols/Footnotes on page 275-281
255
071_DOD_print.qxd
12/12/07
3:03 PM
Page 256
HBO® MERCURY SHORT ARC
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area – w x h (mm)
Luminous Efficacy (lm/W)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 200 W/DC
69225
200
57
DC
3.5
10000
1100
40000
0.75 x 2.3
50
128
102
40
17
1000
s 15
Convection
SFc10-4
SFc10-4
1
58
For more complete product information visit www.sylvania.com
256
HBO 200 W/DC TM
69163
200
56
DC
9500
1000
40000
0.6 x 2.2
50
128
102
40
17
400
s20
Convection
8-32 UNC-3A
8-32 UNC-3A
1
58,200
HBO 202 W/4
69316
200
61
AC
3.6
0
1000
40000
0.6 x 2.2
47.5
128
102
40
17
200
s 45
Convection
SFc10-4
SFc10-4
1
58,69
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 257
HXP® MERCURY SHORT ARC
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Color Temp (K)
Length l max (mm)
Diameter d (mm)
Working Distance A (mm)
Avg Rated Life (hrs)
Hot Restart
Operating Position
Base
Fig No
Symbols & Footnotes
2
HXP R 120 W/17C
69125
120
75
AC
1.4
4400
HXP R 120 W/45 C UV
69120
120
75
AC
1.4
77
56
17.3
2000
p 20
Special
Yes
1
60,170,172,173,174
77
64
45
2000
p 20
Special
Yes
2
60,100,169,170,171,172,
For more complete product information visit www.sylvania.com
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HXP R 120 W/45 C VIS
69119
120
75
AC
1.4
2800
9500
77
64
45
2000
p 20
Special
Yes
2
60,100,169,170,171,172
Symbols/Footnotes on page 275-281
257
071_DOD_print.qxd
12/12/07
3:03 PM
Page 258
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
4
5
HBO 200 W/DN-I
69136
200
25
DC
8.0
HBO 201 W/HS-D2
69168
200
25
DC
8.0
HBO 510 W/FU
69134
200
59
DC
3.0
HBO 250 W/BY
69246
250
40
DC
6.5
HBO 250 W/HS
69364
250
40
DC
6.25
145.8
131
150
127
20
1.9
1000
Horizontal
Convection
20
2
1000
Vertical, anode up
Convection
SFcX32-22
SFcX12-4/15
2
129,160,186
111
120
55
16
2.4
400
Vertical, anode down
Convection
Cable connection
SfcY 10-4/14
3
182
152
125
62
20
2
1000
Vertical, anode down
Forced Base
SFc13-5/20
SFc13-5/20
4
186
143
125
62
20
2
1000
Vertical, anode down
Convection
SFa 13-5/20
Special
5
160,186
1
129,160,186
For more complete product information visit www.sylvania.com
258
3
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 259
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
HBO 350 W
69226
350
68
DC
5.3
4600
128
102
45
20
2.9
600
Vertical, anode down
Convection
SFcY 10-4
SFcY 10-4
1
89,229,230,231
For more complete product information visit www.sylvania.com
3
HBO 350 W/S
69228
350
68
DC
5.15
4700
127
103
52.5
20
3
600
Vertical, anode down
Convection
SFcY10-4
SFcY10-4
1
89,231
4
HBO 450 W/GS
69343
450
50
DC
9.0
150
105
53
22
2.2
600
Vertical, anode down
Convection
SFc 13-8
SFc 13-4
2
291
HBO 500 W/A
69205
500
60
DC
8.3
6230
190
161.5
73
29
4.5
800
Vertical, anode down
Convection
SFcY13-5
SFcY13-5
3
231,235
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 500 W/B
69206
500
48
DC
10.3
5800
180
151.5
78.5
29
3
800
Vertical, anode down
Convection
SFcX13-5/20
SFcY 13-15/20
4
96,231,236
Symbols/Footnotes on page 275-281
259
071_DOD_print.qxd
12/12/07
3:03 PM
Page 260
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
HBO 1000 W/CEL
69175
750
47
DC
16.0
8300
175
157
78.5
28
3
2500
Vertical, anode down
Convection
SxFc15-6/20
SFc15-6/20
1
75,237,243
For more complete product information visit www.sylvania.com
260
3
HBO 1000 W/NEL
69176
750
47
DC
16.0
8300
190
168
84.5
28
3
2500
Vertical, anode down
Convection
SFa15-5/16
SFaX14-5/21
2
97,237,253,254
4
HBO 1002 W/CEL
69177
750
47
DC
16.0
8300
175
157
78.5
28
3
2500
Vertical, anode down
Convection
SFc15-6/20
SXFc15-6/20
3
78,237,244
5
HBO 1002 W/NEL
69273
750
47
DC
16.0
8300
190
168
78.5
28
3
2500
Vertical, anode down
Convection
SFaX14-5/21
SFc15-6/25
4
98,237,243
HBO 1002 W/NIL
69347
750
25
DC
27.1
187
168
78.5
29
3
1500
Vertical, anode down
Forced Base
SFaX14-5/21
SFc15-6/25
5
98,237,243
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 261
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
3
HBO 1003 W/PI
69195
750
26
DC
27.1
HBO 1003 W/PIL
69180
750
26
DC
25.8
197
169.5
85
29
3
850
Vertical, anode down
Forced Base
SFcX14-6/25
SFc15-6/25
1
237,242,249
195
169.5
85
29
3
1500
Vertical, anode down
Forced Base
SFcX14-6/25
SFc15-6/25
1
64,237,242
For more complete product information visit www.sylvania.com
HBO 1000 W/D
69200
1000
38
DC
26.5
10800
240
208
89.5
40
3
1000
Vertical, anode down
Forced Base
SFc15-6/25
SFc15-6/25
2
74,243
HBO 1500 W/CIEL
69171
1500
23
DC
65.2
HBO 1500 W/CIL
69179
1500
23
DC
65.2
262
242
122
52
4
2250
Vertical, anode down
Forced Base
SFa27-20/22
SFa27-20/23
3
258,260,266
262
242
122
52
4
1500
Vertical, anode down
Forced Base
SFa27-10/35
SFa27-20/23
3
260,266
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Symbols/Footnotes on page 275-281
261
071_DOD_print.qxd
12/12/07
3:03 PM
Page 262
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
HBO 1500 W/PI
69319
1500
23
DC
65.2
HBO 1500 W/PIL
69181
1500
23
DC
65.2
HBO 1500 W/PIL HP
69122
1500
23
DC
65.0
267
240
118
47
4
850
Vertical, anode down
Forced Base
SFc30-6/25
SFc27-10/35
1
257,262
273
242
118
46
4
1500
Vertical, anode down
Forced Base
SFc30-6/25
SFc27-10/35
1
61,262
273
242
118
52
4
1500
Vertical, anode down
Forced Base
SFc30-6/25
SFc27-10/35
1
241,242
For more complete product information visit www.sylvania.com
262
3
HBO 2000 W/NIL
69303
1750
26
DC
67.0
5200
241
221
112.25
52
4.5
1500
Vertical, anode up
Forced Base
SFc27-12/35
SFc27-7/35
2
241,260
HBO 2001 W/NIEL
69306
1750
26
DC
67.0
251
231
112.5
52
4.5
2250
Vertical, anode down
Forced Base
SFc27-10/35
SFc27-7/35
3
241,260
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 263
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
3
4
HBO 2001 W/NIL
69292
1750
26
DC
67.0
HBO 2002 W/NIL
69287
1750
24
DC
67.0
HBO 2001 W/CIEL
69166
2000
26
DC
77.0
HBO 2001 W/CIL
69189
2000
26
DC
77.0
HBO 2002 W/MA
69199
2000
37
DC
54.0
251
231
112
50
4.5
1500
Vertical, anode down
Forced Base
SFc27-10/35
SFaX27-7/35
1
241,260
254
234
107.5
52
4.5
1500
Vertical, anode up
Forced Base
SFc27-7/35
SFc27-10x1.25/35
2
79,241
329
309
148.75
62
4
2250
Vertical, anode up
Forced Base
SF33.5/50
SFa33.5-10/50
3
79,114,264
329
307
149
62
4.5
1500
Vertical, anode up
Forced Base
SF33.5/50
SFa33.5-10//50
3
79,241,264
292
272
138.5
62
3
1000
Vertical, anode down
Forced Base
SF27/35
SFa27-10/35
4
79,241,260
For more complete product information visit www.sylvania.com
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Symbols/Footnotes on page 275-281
263
071_DOD_print.qxd
12/12/07
3:03 PM
Page 264
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
4
5
HBO 2002 W/MAL
69121
2000
40
DC
50.0
HBO 2011 W/NIL
69288
2000
24
DC
80.0
HBO 2500 W/PIL
69172
2500
28
DC
90.0
HBO 2501 W/NIL
69289
2500
23
DC
110.0
HBO 2510 W/NIL
69299
2500
23
DC
109.0
292
272
138.5
62
3
1500
Vertical, anode down
Forced Base
SF27/35
SFa27-10/35
1
79,260
256
236
107.75
52
4.5
1500
Vertical, anode up
Forced Base
SFc27-7/35
SFc27-12x1.5/35
2
79,241
350
315
149
62
6.7
1500
Vertical, anode up
Forced Base
SFc30-6/50
SFc30-6.3/50
3
241,242,266
367
327
157.75
70
4.5
1500
Vertical, anode down
Forced Base
SFc33.5-8/50
SFc33.5-14/5
4
79
367
327
157.5
70
4.5
1500
Vertical, anode up
Forced Base
SFc33.5-8/50
SFc33.5-14/50
5
72,241
For more complete product information visit www.sylvania.com
264
3
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 265
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
3
HBO 2700 W/CIL
69344
2700
24
DC
110.0
HBO 3500 W/NIL
69456
3500
27
DC
130
HBO 3500 W/PI
69174
3400
23
DC
148.0
HBO 3500 W/PIL
69169
3400
23
DC
148.0
HBO 3501 W/PI
69127
3400
23
DC
148.0
334
309
148.75
62
4.8
1500
Vertical, anode up
Forced Base
SFa33.5/50
SFa33.5-14.59
1
79,129,264
382
337
180
82
5.5
1500
Vertical, anode up
Forced Base
SFc33.5-16-50
SFa33.5-12/50
2
129,260,284
340
315
154
77
4.5
850
Vertical, anode up
Forced Base
SFaX40-6/50
SFc32.5-6.7/50
3
99,241,266
360
315
154
77
4.5
1500
Vertical, anode up
Forced Base
SFaX40-6/50
SFc32.5-6.7/50
3
241,266
360
315
154
77
4.5
850
Vertical, anode up
Forced Base
SFaX40-6/50
SFc32.5-6.7/50
3
241,266
For more complete product information visit www.sylvania.com
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Symbols/Footnotes on page 275-281
265
071_DOD_print.qxd
12/12/07
3:03 PM
Page 266
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
4
HBO 3501 W/PIL
69165
3400
23
DC
148.0
HBO 3500 W/HK
69137
3500
55
DC
63.5
HBO 4500 W/CIL
69162
4500
30
DC
148.0
HBO 5000 W/TA
69135
5000
50
DC
100.0
HBO 5001 W/UF
69161
5000
62
DC
80.0
360
315
154
77
4.5
1500
Vertical, anode up
Forced Base
SFc32.5-6.7/50
SFaX40-6/50
1
163,266
315
360
315
154
77
4.5
1500
Vertical, anode up
Forced Base
SFAX40-6/50
SFC32.5-6.7/50
1
186
327.5
148.5
80
7.5
850
Vertical, anode up
Forced Base
SFa 33.5-12/50
SFa 33.5-12/50
3
183,266
486
355
206
85
7.5
850
Vertical, anode up
Forced Base
SFa 38-14/65
SFXa 38-14/65
4
135,266
For more complete product information visit www.sylvania.com
266
3
142.7
70
6.4
1000
Vertical, anode up
Forced Base
SFa 27-10/42
SFc 27-14-8/35
2
100,189
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 267
HBO® MERCURY SHORT ARC FOR MICROLITHOGRAPHY
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
2
HBO 5500 W/PI
69164
5000
25
DC
200.0
355
154
85
5.5
850
Vertical, anode up
Forced Base
SFcX 42.5-6/50
SFa 37.5-9/50
1
135,201,266
For more complete product information visit www.sylvania.com
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 5000 W/HK
69138
5100
70
DC
72.0
65.8
355
302
152.5
82
7.5
1000
Vertical, anode down
Forced Base
SFYa29-10/42
SFc29-20-12/42
2
80
Symbols/Footnotes on page 275-281
267
071_DOD_print.qxd
12/12/07
3:03 PM
Page 268
VIP® VIDEO AND DATA PROJECTION
1
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Arc Length (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
VIP R 273/45
69327
270
38
7.1
17000
100000
5800
73
45
67
1.9
1000
Horizontal, tip-off up
Yes
1
1,113,124
For more complete product information visit www.sylvania.com
268
Symbols/Footnotes on page 275-281
071_DOD_print.qxd
12/12/07
3:03 PM
Page 269
SPECTRAL
1
Ordering Abbreviation
Product Number
Elements
Watts (W)
Volts (V)
Current (A)
Type of Current
Operating Position
Base
Fig No
Symbols & Footnotes
2
Na 10 FL
69284
Sodium
9
16
0.57
AC
Vertical, base down
Pico 9
1
119,128
For more complete product information visit www.sylvania.com
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Na/10
69282
Sodium
15
15
1.0
AC
Vertical, base down
Pico 9
2
128
Symbols/Footnotes on page 275-281
269
071_DOD_print.qxd
12/12/07
3:03 PM
Page 270
EXCIMER LAMPS
2
1
3
XERADEX®
D
I
S
P
L
A
Y
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Ordering Abbreviation
Product Number
Watts (W)
Length l1 max (mm)
Length l2 max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Fig No
Symbols & Footnotes
XERADEX 20
69338
20
245
120
75
40
1500
Any
1
115,118,145,147
XERADEX 20/HV
69352
20
245
120
75
40
1500
Any
1
115,118,145,158
LX40T3/956/A3
52079
40
2000
Special
80000
T3
Coated
Yes
350
15
391.5
3
176,204
LX24T3/956/A4
52155
24
2000
Special
48000
T3
Coated
Yes
235
15
267.5
3
176,204
XERADEX 20/SY45/45
69349
20
300
125
45
40
1500
Any
2
115,118,145,148
LINEX®
Ordering Abbreviation
Product Number
Watts (W)
Avg Rated Life (hrs)
Base
Illuminance @ 8mm (Lx)
Bulb
Lamp Finish
Hot Restart
Length L (mm)
Length L1 (mm)
MOL (mm)
Fig No
Symbols & Footnotes
For more complete product information visit www.sylvania.com
270
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 271
LAMP BASES
BA15d
IEC 7004-11
DIN 49721
DL
Bayonet
FaX1.5-3x1
GY6.35-15
IEC 7004-59
2-pin
BA15s
IEC 7004-11A
DIN 49720
SC
Bayonet
G4
IEC 7004-72
DIN 49757
2-pin
BA20d
IEC 7004-12
DIN 49730
GX5.3
IEC 7004-61
DIN 49640
2-pin
GZ6.35
IEC 7004-59 A
DIN 49754
2-pin
For more complete product information visit www.sylvania.com
GZX9.5
GZZ9.5
IEC 7004-70 B
DIN 49756
2-pin
pre-focus
E10
IEC 7004-22
DIN 49610
miniature
Edison
E14
IEC 7004-23
DIN 49615
small
Edison
G5.3-4.8
2-pin
GY5.3
2-pin
G9.5
IEC 7004-70
medium
2-pin
E27/E26
IEC 7004-21
DIN 49620
E26-NA
E27-EURO
G6.35-15
G6.35-20
G6.35-25
IEC 7004-59
2-pin
GX9.5
DIN 49638
IEC 7004-70 A
2-pin
pre-focus
E40/E39
IEC 7004-21
DIN 49625
E39-NA
E40-EURO
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
GX6.35-25
IEC 7004-59
2-pin
GY9.5
GZ9.5
DIN 49756
IEC 7004-70 B
2-pin
pre-focus
Symbols/Footnotes on page 275-281
271
071_DO_drop.qxd
12/13/07
3:25 PM
Page 272
LAMP BASES
GX16d
2-pin
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
G38
IEC 7004-76
MOGUL
Bipost
GY16
DIN 49758
IEC 7004-45
2-pin
GX38q
GY17q
DIN 49758
IEC 7004-74
4-pin
K24s
Length of cable
250 mm
Hole of cable lug
ø 8.4 mm
DIN 49748
P40s
DIN 49728
IEC 7004-43
medium
pre-focus
GY17t
DIN 49665
IEC 7004-45
4-pin
G22
IEC 7004-75
medium
Bipost
Pico9
DIN 41539
GY22
2-pin
PG22-6.35
DIN 49751
IEC 7004-48
P28s
DIN 49728
IEC 7004-42
MOGUL
pre-focus
.
PK30d
R7s
RX7s
DIN 49750
IEC 7004-92
For more complete product information visit www.sylvania.com
272
K30 s
Length of cable
275 mm
Hole of cable lug
dia 8.4 mm
DIN 49748
K39 d
with flexible Siaf cable
Length of cable 300 mm.
Hole of cable lug dia. 8.4 mm
K59 d
with flexible Siaf cable
Length of cable 350 mm.
Hole of cable lug dia. 8.4 mm
DIN 49732
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 273
LAMP BASES
SFcX27-8
(5/16-18UNC-2 A)
SK27-50
SFa5-2
SFa6-2
SFa7.5-2
SFa8-2
SFa9-2
SFa12-11
SFa21-5
SFa15-10
SFa16-8
SFa16-10
SFa20-8
SFa20-10
SFa25-10
SFa27-8
SFa27-10
SFa27-11
SFa27-12
SFa27-14
SFa28-18
SFcX12-4
(with M4 thread and
centering collar)
SFa21-12
DIN 49759
SFc10-4 M4-thread
SFc6-3 M3-thread
SFc12-4 M4-thread
SFc13-4 M4-thread
SFaX27-10
SFaX27-9.5
SFaX27-12
SFaX27-13
SFaX27-14
SFaX30-9.5
SFaX30-16
SX15s
SFc25-14 (M 14x1.5)
SFc27-14 (M 14x1.5)
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
X515
DIN 49613
SFcX 13-4
SFcX 15-4 (with US inch
thread 8-32 UNC-3A and centering collar)
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
273
071_DO_drop.qxd
12/13/07
3:25 PM
Page 274
OPERATING POSITIONS
Schematic diagrams
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
permitted
not permitted
GENERAL INFORMATION
In North America, OSRAM brand Display/Optic lighting products are sold by OSRAM SYLVANIA AND OSRAM SYLVANIA LTD. Sales are
subject to standard terms and conditions of sale prevailing as of the date of purchase.
Operational data and dimensions are nominal values. OSRAM reserves the right to make technical modifications without notice. All
supplies are subject to availability.
® = Registered trademarks of OSRAM GmbH
Lamps are designated in accordance with ANSI standard C78.370-1982 (As amended).
When disposing of spent lamps, always consult federal, state, local and/or provincial hazardous waste disposal rules and regulations to
ensure proper disposal.
Use of improper, unapproved or unsuitable ballasts will negatively impact the performance of Display/Optic lamps and could void the lamp
warranty. A list of power supply manufacturers is available upon request.
Discharge lamps in the HCD®, HMD®, HMI®, HMP®, HTI®, HSR®, HSD®, HBO®, HXP®OSRAM STUDIOLINE® and VIP® types and the spectral
lamps contain small quantities of harmful substances (such as mercury).
For more complete product information visit www.sylvania.com
274
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 275
SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS
Symbol
Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
Footnote
Description
1
Type of current: square-wave AC.
2
Lamp arc needs to be in horizontal operating position.
3
Any operating position allowed with appropriate cooling.
4
In certain countries there are third party property rights relating to equipment which must be observed if these lamps are used in dentistry.
5
Lamp suited for video camera heads; 500hr life @ 1.8V/ 45 min. ON / 15 min. OFF.
6
WARNING: This lamp is designed for heating purposes. It emits a strong Infrared radiation with a temperature at focal point approx. 1300
degrees C. Read Safety and Warning instructions before using this lamp.
7
Lamp also available in BELLAPHOTÖ (Product Number 54163).
8
Lamp also available in BELLAPHOTÖ (Product Number 54840).
9
Lamp service life 75hr life is defined at 76V with a duty cycle of 45 min. ON / 15 min. OFF.
10
Current bar needs to be positioned underneath the discharge arc during operation.
11
Lamp also available in 240 V model.
12
Preferred operating position is horizontal; vertical possible for short periods.
13
Lamp has internal proximity reflector.
14
Base - filament connections: Pins 1 and 4.
15
Lamp has monoplane filament 10 X 10 mm.
16
Lamp has monoplane filament.
17
Lamp also available as a 240V model (Product Number 54977).
18
Lamp has a biplane filament.
19
WARNING: Lamp has a special GY22 base. Ignition voltage must be applied only to the thin pin.
20
Lamp interchangeable with HX 602
21
Lamp interchangeable with HX 600
22
Lamp also available as 115V model (Product Number 54636).
23
Lamp has two separately switchable filaments.
24
Length l = Contact to contact.
25
Lamp also available in 240 V version : Product Number 54619.
26
High-performance HPL halogen lamps are manufactured under license from ETC,Inc.
27
Do not tilt perpendicular to the filament.
28
WARNING: The contact pins on the base are connected internally. The electrode farthest from the base must be connected via cable.
29
MFL=Medium Flood
30
NSP=Narrow Spot
31
WFL=Wide Flood
32
VNSP=Very Narrow Spot.
33
With biplane filament , higher luminous intensity can be achieved.
34
Lamp has a flat core filament with filament area perpendicular to the lamp axis.
35
Hg 100 also suitable for DC operation (no igniter needed when connected to 230V)
36
Lamp also available with connecting cable and plug-in contact.XBO R 180W/45 C OFR (Product Number 69183).
37
Lampholder for FaX 1.5 base = HMI Socket 46721 (Product Number 69302).
38
Lamp also available in ozone-free version XBO 75 W/2 OFR (Product Number 69232)
39
Lamp also available in ozone-free version XBO 150 W/1 OFR (Product Number 69235)
40
Lamp uses Suprasil quartz glass.
41
Lamp also available in ozone-free version XBO 450 W OFR (Product Number 69245)
42
Lamp also available in Suprasil quartz glass version XBO 450 W/4 (Product Number 69244)
43
S=Short
44
C=Base with Cable
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com
275
071_DO_drop.qxd
12/13/07
3:25 PM
Page 276
SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
Footnote
Description
45
H=Suitable for horizontal operation
46
TC=Thread and Cable
47
CA=Cable on anode base
48
All HTI« lamps are hot restrikeable with the exception of HTI 150, HTI 152, HTI 405 W/SE, and 705 W/SE.
49
SHSC=Extra short version for horizontal burning position, anode connection via cable (super short)
50
TM=Threaded Modified
51
TP=Threaded Pin
52
GS=Gap Shortened
53
SE=Single Ended
54
DE=Double Ended
55
DX= Double Ended eXtreme Seal technology
56
OFR=Ozone Free
57
Molybdenum pins have 1mm diameter.
58
s (Operating Position) = Vertical, base down
59
h (Operating Position) = Vertical, base up
60
p (Operating Position) = Horizontal
61
Lamp also available with 850 hr HBO 1500 W/PI (Product Number 69319)
62
Lamp also available as version HBO 2001 W/CI with 850hr life (Product number 69219)
63
Lamp is also available with connecting cable and plug-in contact. HTI 250W/32 C (Product Number 54089).
64
Lamp also available as version HBO 1003 W/PI with 850hr life (Product Number 69195)
65
Lamp also available as version HBO 2500 W/PI with 850hr life (Product Number 69178)
66
Technical data if operated on AC: Current = 7.1 A, Volts = 67 V.
67
Average service life of lamp if operated with 400W is 100 hrs.
68
Magnetic arc stabilization required.
69
Lamp same as HBO 200 W/4 (Product Number 69224 but with increased radiation in the wavelength range below 450nm for UV-curing.
70
Technical lamp data if operated on AC: Current=4.2 A, Volts=65 V, Lumens=10,000 lm, Luminous Efficacy=50 lm/W.
71
Electrical data if lamp is operated on AC: Current=7.8 A, Volts=67 V.
72
Lamp has been specially adjustment for uniform illumination in the far field(200-250) mm focal length.
73
Cathode Base with 8-32 UNC-3A thread.
74
Anode Base=Sleeve base with M 6 thread.
75
Anode Base=Hexagon base with M 6 thread.
76
Anode Base with 8-32 UNC-3A thread.
77
Anode Base=Sleeve base with cooling fins and cable connection (M 6).
78
Anode Base with M 6 thread.
79
Anode Base with cable connection (M 8).
80
Anode Base with cable connection (M 6).
81
Anode Base with 8-32 UNC-3 thread.
82
Pin dimensions at front ceramic ring 2mm diameter, 10 mm length. Pin dimensions at rear ceramic base cap 2.5mm diameter, 11mm length.
83
Anode base with M 5x 0.9 thread
84
Cathode Hexagon base with M 5x 0.9 thread
85
Anode base with cable: length 340mm; connector 8/25.
86
For DC operation both Product Numbers 69198 & 69222 can be used (47...65Volts / 3.1...4.2Amps). For AC operation Product Number
69198 (L1 version 57 65 Volt / 3.6 Amps) or Product Number 69222 (L2 version 49 57 Volt / 4.2 Amps) can be used.
87
Product Number 69223 can be used for DC operation (47...65 Volts / 3.1...4.2Amps) and for AC operation (L2 version 49 57 Volt / 4.2
Amps).
88
For DC operation Product Number 69204 can be used (67-85 Volts / 5.9 - 7.4 Amps). For AC operation Product Number 69204 can be used
(L2 version 69-77 Volt / 7.8 Amps).
89
Anode and Cathode Base with UNC-3B thread.
90
Type of current: sine-wave (sinusoidal) AC.
For more complete product information visit www.sylvania.com
276
071_DO_drop.qxd
12/13/07
3:25 PM
Page 277
SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS
Footnote
Description
91
Photometric data refer to discharge tube (lamp burner).
92
Lamp also available with 850 hrs (HBO 3500 W/PI, Product Number 69174)
93
Lamp also available with 850 hrs (HBO 3501 W/PI, Product Number 69127)
94
Lamp also available as Longlife version HBO 2500 W/PIL with 1500hr life (Product Number 69172).
95
Lamp also available as Longlife version HBO 3500 W/PIL with 1500hr life (Product Number 69169).
96
Cathode base with M 5x 0.9 thread
97
Cathode base with cable connection (M5)
98
Anode Base=Sleeve base with cable connection (M5)
99
Lamp also available as Longlife version HBO 3500 W/PIL with 1500hr life (Product Number 69169).
100
Anode base with cable connection
101
Length l1 = Contact to contact.
102
Lamp has a parabolic reflector.
103
Lamp wattage - After seasoning for 1/2 hour 1000 watts based on 2 filaments together, 400 watts based on 1 filament.
104
Average service life = 25 hrs. based on 2 filaments together, 100 hrs. with 1 filament.
105
Average service life = 50 hrs. based on 2 filaments together, 100 hrs. with 1 filament.
106
Ignition voltage = 36 kVs
107
Ignition: Min. open circuit voltage for cold / hot ignition = 85 / 110 V
108
Cooling: Min. air flow velocity around discharge vessel = 6 m/s
109
Magnetic arc stabilization: necessary for horizontal operation
110
Product number 54100 is the replacement for product number 54048.
111
HMI PAR lens set for OSRAM HMI 1200 PAR 64 comprising of NSP, VNSP, MFL, and VWFL lenses.
112
OSRAM socket #46721, cable length 22" for use with the following OSRAM lamps: HTI 400W/SE (product number 54084), HTI 600W/SE
(product number 54087), and HMI 250W/SE (product number 54062).
113
Lamp has a elliptical reflector.
114
Lamp also available as version HBO 2001 W/CIL with 1500hr life (product number 69189)
115
The XERADEX 20 lamp must be operated with DBD 20/110-240/ECG-XERADEX power supply (Product Number 69128 or 69129).
116
This power supply is designed to operate the XERADEX 20 lamp (Product Number 69338).
117
Lumens refers to screen lumens.
118
XERADEX lamps are only to be operated in appropriate equipment. Read and understand the Product Safety Warnings before using this
product. XERADEX lamps generate a strong 172 nm (VUV) radiation. This short-wave radiation will convert atmospheric oxygen (O2) surrounding the lamp into ozone (O3). Ozone gas is toxic when inhaled in high concentrations over long periods of time. Ozone levels can be
measured and monitored with commercial measuring equipment. Always keep ozone levels below the applicable TLV (threshold limit value).
119
For Na 10 FL (product number 69284) use adapter no. 454/s using Pico 9 bases with P28 sockets.
120
Lamp also available with male connectors (Product Number 58722)
121
Lamp also available with female connectors (Product Number 58697)
122
Lamp also available with male connectors (Product Number 58726)
123
Lamp also available with female connectors (Product Number 58721)
124
All VIP« lamps are for AC operation on electronic power supplies and are hot restrikeable. All VIP« lamps need forced cooling.
125
Lamp also available with female connectors (Product Number 58709)
126
Lamp also available with female connectors (Product Number 58717)
127
Clean room ready packaging.
128
Safety: Because the danger from glare, UV radiation and overpressure during operation, spectral lamps may only be operated in sealed housings specially designed for the purpose. Suitable filters must be fitted to ensure that UV radiation is reduced to permissible levels.
129
This lamp has positive pressure even when cold. Please read safety/warning instructions before using this lamp.
130
Line drawing represented does not show cable connection.
131
Lamp HSD 250/78 also available with 7800K color temperature and average rated life at 3000 hr. Product Number 54118.
132
Lamp XBO 10000 W/HS OFR also available with current control range 160-299 amps. Product Number 69342.
133
Lamp HSD 250 also available with 6000K color temperature and average rated life at 2000 hr. Product Number 54170.
134
Connector = Female, round, with 4mm pin.
For more complete product information visit www.sylvania.com
277
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
071_DO_drop.qxd
12/13/07
3:25 PM
Page 278
SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
Footnote
Description
135
Lamp life may vary depending on duty cycle and application.
136
Connector = Female.
137
Connector = Male.
138
Snap-on connector, female / male contact.
139
In horizontal operation position it is recommended that the "lead connection" wire be in the top position with filler tip facing down.
140
This lamp type is twice the life of the ANSI standard version.
141
This lamp type is twice the life of the standard version.
142
Please see Product Number 58795 for double life version.
143
Please see Product Number 58789 for double life version.
144
Please see Product Number 58794 for double life version.
145
XERADEX lamp life is rated in terms of 70% of initial UVC output on a continuous burn cycle.
146
Lamp also available with connecting cable and plug-in contact. XBO R 100W/45 C OFR (Product Number 69191).
147
Base is KF50 flange fitting; lamp is designed for use in vacuum environments at pressures above 300 mbar.
148
Base is KF40 flange fitting; lamp is designed for use in high vacuum environments at pressures above 30 mbar and below 10^-3 mbar.
149
Please see Product Number 58779 for double life version.
150
Please see Product Number 58819 for double life version.
151
Please see Product Number 58821 for double life version.
152
Maximum permitted base temperature is 350 degrees C at molybdenum foil / pinch seal region.
153
Distance b = Ignition Electrode. Base for ignition electrode is SFc 6-3.
154
HBO 200W L1 and HBO 200W L2 can be operated on AC or DC.
155
HBO 200W L1 (Product Number 69218) technical data if operated on AC current: Volts = 61 +/- 4, Current (A) = 3.6.
156
HBO 200W L2 (Product Number 69220) technical data if operated on AC current: Volts = 53 +/- 4, Current (A) = 4.2.
157
Distance a is from end of base to the respective electrode tip (cold) - see lamp drawing.
158
Base is KF50 flange fitting; lamp is designed for use in high vacuum environments at pressures above 200 mbar and below 10^-3 mbar.
159
For use indoors or outdoors. When used outdoors, protect the lens of the bulb from direct contact with moisture (rain, snow, etc.) to avoid
cracking or breaking.
160
2000hr warranty against non-passive lamp failure.
161
Optimized lamp eXtreme Seal (XS) technology to withstand interior base temperatures of up to 450 degrees celsius.
162
When operated on electronic control gear (ECG) service life extended to 3000h.
163
Also available with 850h, HBO 3501 W/PI: NAED 69127.
164
SHP - series (Super High Performance Technology).
165
Lamp focus is 60mm in front of reflector rim.
166
Lamp is part of the SharXS HTI lamp series. All SharXS HTI lamps are identical in terms of their shape, size, and bases.
167
Base has notch for pre-alignment.
168
Lamp current not to exceed 7.2A.
169
125 mm (front ring to plug) and 95 mm (rear cap to plug) silicon cables terminated with MATE-N-LOK plug no. 350809-1 with pins no.
926868-3 by AMP Inc.
170
It takes time for the mercury in the lamp to evaporate. Typically 95% of luminous output are generated after approximately 120 seconds. For
quality inspection purposes allow for five minutes burning time.
171
Excessive airflow may lead to mercury condensation in the discharge lamp bulb and consequently to a performance drop.
172
Operation time after which either aperture lumens decrease to 50% of initial value or the lamp voltage reaches 115 V and the lamp cannot be
ignited. Switching cycle: 210 minutes on / 30 minutes off.
173
Operational bulb wall temperatures lower than 850˚C may lead to mercury condensation and prevent the lamp from reaching stable operation
conditions; temperatures higher than 950˚C may lead to premature failures of the lamp.
174
For rectangular aperture of 5.0 x 3.8 mm (hor. x vert.) at working distance 17.3 mm.
175
Output is understood as total energy in the range 320 … 500 nm focused on an aperture with diameter d at working distance a in front of the
reflector.
For more complete product information visit www.sylvania.com
278
071_DO_drop.qxd
12/13/07
3:25 PM
Page 279
SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS
Footnote
Description
176
Beam Angle data refers to aperture.
177
Lamp is suited for use in ASML equipment (PAS 5500/22, /100, /100B, /TFH100).
178
The QXL lamp allows easy one-hand replacement without opening the light fixture. 1/4 turn twist in/out, no tool required.
179
With vertical operating position: anode(+) on top.
180
QXL is a trademark of Electronics Theatre Controls Inc., and used under license
181
The QXL 750/77 lamp has been designed and approved by ETC in the Source Four® Revolution™
182
Anode: Cable connection length 110mm
183
Cathode Base with cable connection (M 12).
184
Lamp uses eXtreme Seal (XS) Technology, which effectively protects the seal up to 500˚C.
185
Cable Connector TP120.
186
This lamp is used for OEB/WEE applications.
187
Lamp is interchangeable with FLK naed 54589
188
Lamp is interchangeable with FLK PLUS HPR 575/115 naed 54549
189
Lamp designed for the manufacture of printed Board Circuits in Hakuto exposure equipment HAP 3500 and 3510 series
190
The focus lies 45mm in front of the mounting rim (working distance).
191
Lamp description changed from HSD 200 to HSD 200W/60 4ARXS
192
Lamp description changed from HTI 575 W/DE to HTI 575/D5/56 Baby-Sharxs
193
Includes screw hole in anode lamp base with installed cable. No screw hole in cathode lamp base.
194
Includes screw hole in anode & cathode lamp base. Includes 1 installed cable for anode lamp base. Cathode cable provided on request when
ordering.
195
Includes screw hole in anode & cathode lamp base. Includes 1 anode cable & 1 cathode cable in box, not installed.
196
HTI 1200W/D7/60 SharXS lamp (Product No. 54268-10 case & 54202-30 case) is a direct and equal replacement for the HMI 1200W/S lamp
(Product No.54088)
197
Cathode Base with Cable connection (M 10)
198
Easy disassembly into components allow for environmentally preferred waste disposal
199
Aluminum reflector reduces weight by up to 50% compared to standard glass PAR lamps
200
The HBO 200 W/DC TM is a direct and equal replacement for the HBO 200 W/2 TM (product No. 69221)
201
Lamp bases need to be forced cooled.
202
The connecting cables do not have a plug-in connector.
203
XIR=Xenon Infrared
204
Average service life can vary by application. Call National Customer Sales and Support (888) 677-2627 for more information.
205
Connector = female, flat
206
Lamp is part of the Baby SharXS HTI lamp series. All Baby SharXS HTI lamps are identical in terms of their shape, size, and bases.
207
Reinforced pinch-seal neck design for moving head applications
208
Connector = female, round
209
Connector = male, flat
210
LA= Lumen Advanced (High Efficiency Lamp)
211
Photometric values are measured at rated current.
212
Lamp also available in Suprasil quartz glass version: XBO 150 W/4 (Product Number 69238).
213
Lamp is suitable for Crosfield color scanner (CR = Crosfield).
214
Photometric data is measured in vertical operating position at rated wattage.
215
Lamp also available in Suprasil quartz version: XBO 450 W/4 (Product Number 69244).
216
For vertical operating position; anode(+) on top.
217
Lamp has same dimensions as XBO 1600 W/HSC OFR (Product Number 69268).
218
Lamp also available as XBO 2001 W/HTP OFR (Product Number 69310).
219
Necessary input voltage: 380 volt.
220
Lamp also available as XBO 4200 W/GS with 60mm bulb diameter and 500 hrs life.
221
Lamp also available as XBO 5000W/HBM OFR with anode base SFaX30-9,5 and cathode base SFa30-8.
222
Lamp optimized for fluorescence microscopy.
223
Lamp also available with AMP plug contact. HBO R 103/45 C (Product Number 69311).
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com
279
071_DO_drop.qxd
12/13/07
3:25 PM
Page 280
SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
Footnote
Description
224
HBO 200W/2 and HBO 500W/2 can be operated on AC or DC.
225
Lamp also available with increased radiation in the wavelength range below 450nm for UV-curing. HBO 202W/4 (Product Number 69316).
226
Lamp also available with threaded pin 8-32 UNC-3A: HBO 200 W/2TM (Product Number 69223).
227
Technical data if operated on AC current: Volts=65, Lumens=10,000 lm, Luminous Efficacy=50 lm/W.
228
Lens set available (NSP,MFL,WFL,SWFL) Ref. No. 46771.
229
Lamps suitable for pulse operation between 250W and 500W. Maximum permissible average power is 350W (also for constant
power operation).
230
HBO 350W (Product Number 69226) replaces HBO 350 W/G (Product Number 69227).
231
Lamp service life is defined with a switch-on/switch off duty cycle of 12hours ON / 30 minutes OFF.
232
Distance a = Distance (cold) of either anode base to anode tip or cathode base to cathode tip depending on lamp type.
233
NOTE: Maximum permitted base temperature: 230 degrees C (446 degrees F).
234
lamp base is with 8-32 UNC-3A thread.
235
Lamp base(s) with M 5x0.9 thread.
236
Lamp anode base (hexagon) with thread M5x0.9
237
Lamps suitable for pulse operation between 700W and 1000W. Maximum permissible average power is 750W (also for constant
power operation).
238
Available in 2500 hrs. life: HBO 1000 W/CEL (Product Number 69175).
239
Discharge tube needs to be in horizontal operating position.
240
Available in 2500 hrs. life: HBO 1002 W/CEL (Product Number 69177).
241
Lamp should not be ignited more than ten times over lifetime.
242
Lamp has cooling fins on anode base.
243
Cathode Base=Sleeve base with M 6 thread.
244
Cathode Base=Hexagon base with M 6 thread.
245
Lamp has anode base with cooling fins and cable connection (M 6).
246
Lamp is available in 2500 hrs life: HBO 1000 W/NEL (Product Number 69176).
247
Lamp is available in 2500 hrs. life: HBO 1002 W/NEL (Product Number 69273).
248
The radiant Power of the I-line is measured in the wavelength range: 365 + 2.5 nm.
249
Lamp also available as Longlife version HBO 1003 W/PIL (Product Number 69180) with 1500hr life.
250
Lamp filler tip needs to point upwards during operation.
251
Cathode Base=Sleeve base with cooling fins and cable connection (M 6).
252
Cathode Base with M 6 thread.
253
Cathode Base with cooling fins.
254
Anode sleeve base without thread.
255
Anode Base=Sleeve base with cable connection (M 6).
256
Maximum permitted base temperature: 200 degrees C (392 degrees F).
257
Lamp also available as Longlife version HBO 1500 W/PIL (Product Number 69181) with 1500hr life.
258
Lamp also available as Longlife version HBO 1500 W/CIL (Product Number 69179) with 1500hr life.
259
Lamp also available as Longlife version HBO 2001 W/NIL with 1500hr life (Product Number 69292).
260
Cathode Base with cable connection (M 8).
261
Permitted wattage range: 300W to 600W.
262
Anode Base=Cooling fins with cable connection (M 8).
263
The average rated life of this lamp depends on the operating mode (initial power setting).
264
Cathode Base with cable connection (M 6).
265
Lamp also available as Longlife version HBO 2501 W/NIL (Product Number 69289) with 1500hr.
266
Anode Base with cable connection (M 10).
267
Lamp has round-core double filament.
268
Male contacts according to DIN 46248.
269
Lamp is also available with male contact(Product Number 58724).
270
Permitted wattage range: 400W to 700W.
271
Female contact is according to DIN 46247.
For more complete product information visit www.sylvania.com
280
071_DO_drop.qxd
12/13/07
3:25 PM
Page 281
SYMBOLS & FOOTNOTES FOR DISPLAY/OPTIC LAMPS
Footnote
Description
272
Despite transverse filament, lamp can be inclined at any angle in s 90 position.
273
Lamp has snap-on male contact to DIN 46248.
274
Lamp also available with male contact according to DIN 46248. 64361/HLX Z (Product Number 58717)
275
Lamp has D.C. Bay Ring.
276
WARNING: Lamp only for use where seal temperature does not exceed 650 degrees F (343 degrees C). Minimum bulb wall temperature 480
degrees F (249 degrees C).
277
Lamp has 1.75 inch (44.45mm) stranded Nickel leads.
278
Max. Beam Candlepower (MBCP) : 175 kcd.
279
D=Digital
280
XL=Xtreme Life
281
CL=Classic Line
282
HP=High Performance
283
S=Sony (Sony projector)
284
Anode base with thread (M16)
285
High temperature base. Retards seal deterioration where seal temperature exceeds 650˚F.
286
For use where seal temperature does not exceed 650˚F.
287
Life at rated voltage and at 650˚F maximum seal temperature.
288
Usually limited to intermittent burning.
289
A suitable protective shield, screening technique, or both must be used to protect people and surroundings from the possibility of a lamp
shattering and from possible ultraviolet radiation.
290
Bulk pack= 30/case
291
Anode: Hexagon base with thread 8-32 UNC
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com
281
071_DO_drop.qxd
12/13/07
Index by Ordering
Abreviation
Type
D
I
S
P
L
A
Y
O
P
T
I
C
I
N
D
E
X
3:25 PM
Page 282
Type
Page
111A . . . . . . . . . . . . . . . . . . . . . . . .217
140 . . . . . . . . . . . . . . . . . . . . . . . . . .217
211 118V . . . . . . . . . . . . . . . . . . . . .217
212 118V . . . . . . . . . . . . . . . . . . . . .217
4551 . . . . . . . . . . . . . . . . . . . . . . . . .220
4557 . . . . . . . . . . . . . . . . . . . . . . . . .220
4559 . . . . . . . . . . . . . . . . . . . . . . . . .220
5557 . . . . . . . . . . . . . . . . . . . . . . . . .220
8013 . . . . . . . . . . . . . . . . . . . . . . . . .213
8013 . . . . . . . . . . . . . . . . . . . . . . . . .219
8017 . . . . . . . . . . . . . . . . . . . . . . . . .213
8017 . . . . . . . . . . . . . . . . . . . . . . . . .219
8018 . . . . . . . . . . . . . . . . . . . . . . . . .213
8018 . . . . . . . . . . . . . . . . . . . . . . . . .219
8100 . . . . . . . . . . . . . . . . . . . . . . . . .213
8100 . . . . . . . . . . . . . . . . . . . . . . . . .219
62138 HLX . . . . . . . . . . . . . . . . . . . .213
64223 . . . . . . . . . . . . . . . . . . . . . . . .214
64251 HLX . . . . . . . . . . . . . . . . . . . .214
64255 . . . . . . . . . . . . . . . . . . . . . . . .214
64258 AHLX . . . . . . . . . . . . . . . . . . .214
64258 HLX . . . . . . . . . . . . . . . . . . . .214
64260 . . . . . . . . . . . . . . . . . . . . . . . .214
64261 . . . . . . . . . . . . . . . . . . . . . . . .214
64265 HLX . . . . . . . . . . . . . . . . . . . .214
64275 . . . . . . . . . . . . . . . . . . . . . . . .214
64291 XIR 40W . . . . . . . . . . . . . . . .214
64292 XIR 150W . . . . . . . . . . . . . . .214
64501 . . . . . . . . . . . . . . . . . . . . . . . .217
64513 . . . . . . . . . . . . . . . . . . . . . . . .214
64514 . . . . . . . . . . . . . . . . . . . . . . . .214
64515 . . . . . . . . . . . . . . . . . . . . . . . .214
64516 . . . . . . . . . . . . . . . . . . . . . . . .214
64573 . . . . . . . . . . . . . . . . . . . . . . . .217
64575 . . . . . . . . . . . . . . . . . . . . . . . .217
64579 115-120V . . . . . . . . . . . . . . .216
64602 . . . . . . . . . . . . . . . . . . . . . . . .214
64611 HLX . . . . . . . . . . . . . . . . . . . .214
64614 . . . . . . . . . . . . . . . . . . . . . . . .217
64617 . . . . . . . . . . . . . . . . . . . . . . . .214
64617 SPOT . . . . . . . . . . . . . . . . . . .214
64621 HLX . . . . . . . . . . . . . . . . . . . .219
64624 . . . . . . . . . . . . . . . . . . . . . . . .214
64635 HLX . . . . . . . . . . . . . . . . . . . .214
64637 . . . . . . . . . . . . . . . . . . . . . . . .214
64638 HLX . . . . . . . . . . . . . . . . . . . .214
64650 . . . . . . . . . . . . . . . . . . . . . . . .214
64664 HLX . . . . . . . . . . . . . . . . . . . .214
64665 HLX . . . . . . . . . . . . . . . . . . . .214
64668 XIR 80W . . . . . . . . . . . . . . . .214
64805 CP/85 (CP/29) . . . . . . . . . . . .217
70313 (390158) . . . . . . . . . . . . . . . .214
70314 (390153) . . . . . . . . . . . . . . . . .24
70314 (390153) . . . . . . . . . . . . . . . .219
70335 BULK . . . . . . . . . . . . . . . . . . .215
70335 BULK . . . . . . . . . . . . . . . . . . .219
14V/35W/M/GZ4 . . . . . . . . . . . . . . .213
20PAR/36/CAP/WFL . . . . . . . . . . . . .217
60T4QCL . . . . . . . . . . . . . . . . . . . . .213
85T3/RM . . . . . . . . . . . . . . . . . . . . .213
120/T4/SPECIAL . . . . . . . . . . . . . . .213
150/25T4 . . . . . . . . . . . . . . . . . . . . .217
220T4Q/2PPF . . . . . . . . . . . . . . . . . .213
235T4Q/2PPF . . . . . . . . . . . . . . . . . .213
350PAR56/SP . . . . . . . . . . . . . . . . .219
500T3Q/IR 120V . . . . . . . . . . . . . . .219
500T3Q/IR/7 120V . . . . . . . . . . . . . .219
1000/240V/G9.5 . . . . . . . . . . . . . . . .219
1000Q/T6/RTP/C . . . . . . . . . . . . . . .219
1000Q/T6/RTPFS . . . . . . . . . . . . . . .219
1000T3Q/IR 230-250V . . . . . . . . . . .219
1000T6QRTP/X . . . . . . . . . . . . . . . .219
1000TQ/RTP/CR/BULK . . . . . . . . . . .219
1200T3Q/IR/CL/HT 144V . . . . . . . . .219
1500T6Q/RTP/GS . . . . . . . . . . . . . . .219
1600T3Q/IR 240V . . . . . . . . . . . . . .219
1600T3Q/IR 277V . . . . . . . . . . . . . .219
1600T3Q/IR/7 240V . . . . . . . . . . . . .219
2000T8Q/120V/G22 . . . . . . . . . . . . .219
2500T3Q/IR 480V . . . . . . . . . . . . . .219
For more complete product information visit www.sylvania.com
282
Page Type
2500T3Q/IR/7 480V . . . . . . . . . . . . .219
2500T8Q/120V . . . . . . . . . . . . . . . . .219
3650T3Q/IR/CL 480V . . . . . . . . . . . .219
3800T3Q/IR 570V . . . . . . . . . . . . . .219
4515 PAR36 30W . . . . . . . . . . . . . .217
6.6A/30T3.5/64322/EXL/DL . . . . . . .220
6.6A/30T3.5/EXL . . . . . . . . . . . . . . .220
6.6A/30T10/1P . . . . . . . . . . . . . . . . .220
6.6A/45T3/CL/64315 . . . . . . . . . . . .220
6.6A/45T3.5/64320/EXM . . . . . . . . .220
6.6A/45T3.5/EXM . . . . . . . . . . . . . . .220
6.6A/45T3.5Q/64321 . . . . . . . . . . . .220
6.6A/45T4/64319 FEMALE . . . . . . . .220
6.6A/45T4/64319Z . . . . . . . . . . . . . .220
6.6A/45T4/CL/64317 . . . . . . . . . . . .220
6.6A/45T4CL/64318 . . . . . . . . . . . . .220
6.6A/45T10/P . . . . . . . . . . . . . . . . . .220
6.6A/100T4/64341/HLX . . . . . . . . . .221
6.6A/100T4/64341Z/HLX . . . . . . . . .221
6.6A/100T4/64342/HLX . . . . . . . . . .221
6.6A/115T4Q/58798/2PPF/EVV . . . .221
6.6A/150T4/64361/HLX . . . . . . . . . .221
6.6A/150T4Q/64354/EWR/DL . . . . .221
6.6A/150T4Q/64361Z/HLX . . . . . . . .221
6.6A/30MR16/64331A/FL . . . . . . . .220
6.6A/30MR16/64331A/SP . . . . . . . .220
6.6A/30MR16/64331AC/FL . . . . . . .220
6.6A/40MR11/64333A . . . . . . . . . . .220
6.6A/40MR11/64333B . . . . . . . . . . .220
6.6A/45MR16/64337A 45-15 . . . . . .220
6.6A/45MR16/64337B 45-15 . . . . . .220
6.6A/48MR16/64337A 48-15 . . . . . .220
6.6A/48MR16/64337A LL IRC . . . . .220
6.6A/48MR16/64337B LL IRC . . . . .221
6.6A/48MR16/64337C LL IRC . . . . .221
6.6A/48W/MR16/64338AC . . . . . . . .220
6.6A/62W/MR16/64336A . . . . . . . . .221
6.6A/105MR16/64339A . . . . . . . . . .221
6.6A/105MR16/64339AC . . . . . . . . .221
6.6A/105MR16/64339B . . . . . . . . . .221
6.6A/105MR16/64339C . . . . . . . . . .221
6.6A/200PAR64Q/2P . . . . . . . . . . . .221
6.6A/200T4/64382A/HLX . . . . . . . . .221
6.6A/200T4/64382C/HLX . . . . . . . . .221
6.6A/200T4Q/2PPF/58750/EZL/DL . .221
6.6A/200T4Q/64386 . . . . . . . . . . . . .221
6.6A/200T4Q/CL/DCR/58746/DL . . .221
6.6A/200T5/CL/64380 . . . . . . . . . . .221
6.6A/65T4/64328Z/HLX . . . . . . . . . .221
aluPAR 56/NSP/300W/120V . . . . . .218
aluPAR 56/MFL/300W/120V . . . . . .218
aluPAR 56/WFL/300W/120V . . . . . .218
aluPAR 56/NSP/300W/230V . . . . . .218
aluPAR 56/MFL/300W/230V . . . . . .218
aluPAR 56/WFL/300W/230V . . . . . .218
aluPAR 56/NSP/500W/120V . . . . . .218
aluPAR 56/MFL/500W/120V . . . . . .218
aluPAR 56/WFL/500W/120V . . . . . .218
aluPAR 64/NSP/500W/120V . . . . . .218
aluPAR 64/MFL/500W/120V . . . . . .218
aluPAR 64/WFL/500W/120V . . . . . .218
aluPAR 64/NSP/500W/230V . . . . . .218
aluPAR 64/MFL/500W/230V . . . . . .218
aluPAR 64/VNSP/1000W/120V . . . .218
aluPAR 64/NSP/1000W/120V . . . . .218
aluPAR 64/MFL/1000W/120V . . . . .218
aluPAR 64/WFL/1000W/120V . . . . .218
aluPAR 64/NSP/1000W/230V . . . . .218
aluPAR 64/MFL/1000W/230V . . . . .218
aluPAR 64/WFL/1000W/230V . . . . .218
BAA . . . . . . . . . . . . . . . . . . . . . . . . .211
BBA 118V . . . . . . . . . . . . . . . . . . . . .211
BCA 118V . . . . . . . . . . . . . . . . . . . . .215
BCM . . . . . . . . . . . . . . . . . . . . . . . . .215
BHC/DYS/DYV . . . . . . . . . . . . . . . . .215
BHC/DYS/DYV-5 . . . . . . . . . . . . . . .215
BRJ/EVB 64633 HLX . . . . . . . . . . . .211
BRL 64610 HLX . . . . . . . . . . . . . . . .211
BRN . . . . . . . . . . . . . . . . . . . . . . . . .211
BTL . . . . . . . . . . . . . . . . . . . . . . . . .215
BTM . . . . . . . . . . . . . . . . . . . . . . . . .215
BTN . . . . . . . . . . . . . . . . . . . . . . . . .215
BTP . . . . . . . . . . . . . . . . . . . . . . . . .215
Page Type
BTR . . . . . . . . . . . . . . . . . . . . . . . . .215
BVE . . . . . . . . . . . . . . . . . . . . . . . . .211
BVM 64540 . . . . . . . . . . . . . . . . . . .215
BVT . . . . . . . . . . . . . . . . . . . . . . . . .215
BVV . . . . . . . . . . . . . . . . . . . . . . . . .215
BVW . . . . . . . . . . . . . . . . . . . . . . . . .215
CAX . . . . . . . . . . . . . . . . . . . . . . . . .211
CXZ . . . . . . . . . . . . . . . . . . . . . . . . .215
CYV . . . . . . . . . . . . . . . . . . . . . . . . .215
CYX . . . . . . . . . . . . . . . . . . . . . . . . .215
DDL . . . . . . . . . . . . . . . . . . . . . . . . .211
DDM . . . . . . . . . . . . . . . . . . . . . . . . .211
DDS . . . . . . . . . . . . . . . . . . . . . . . . .211
DED . . . . . . . . . . . . . . . . . . . . . . . . .211
DNE . . . . . . . . . . . . . . . . . . . . . . . . .211
DNF . . . . . . . . . . . . . . . . . . . . . . . . .211
DNS/FMC . . . . . . . . . . . . . . . . . . . . .215
DPY . . . . . . . . . . . . . . . . . . . . . . . . .215
DTA . . . . . . . . . . . . . . . . . . . . . . . . .215
DTY . . . . . . . . . . . . . . . . . . . . . . . . .215
DWE . . . . . . . . . . . . . . . . . . . . . . . . .215
DWT . . . . . . . . . . . . . . . . . . . . . . . . .215
DXW . . . . . . . . . . . . . . . . . . . . . . . . .215
DYH . . . . . . . . . . . . . . . . . . . . . . . . .211
DYS/300 . . . . . . . . . . . . . . . . . . . . .215
DYS/300 . . . . . . . . . . . . . . . . . . . . .217
DZE/FDS . . . . . . . . . . . . . . . . . . . . . .211
EBV 118V . . . . . . . . . . . . . . . . . . . . .211
ECA 120V . . . . . . . . . . . . . . . . . . . . .211
ECR 64815 CP/83 230V . . . . . . . . . .215
ECT 120V . . . . . . . . . . . . . . . . . . . . .211
EFM 64607 . . . . . . . . . . . . . . . . . . . .211
EFN 64615 HLX . . . . . . . . . . . . . . . .211
EFP 64627 HLX . . . . . . . . . . . . . . . .211
EFP/X 64629 HLX . . . . . . . . . . . . . .211
EFR 64634 HLX . . . . . . . . . . . . . . . .211
EFR-5/X 64620 HLX . . . . . . . . . . . . .211
EFX . . . . . . . . . . . . . . . . . . . . . . . . . .215
EGE . . . . . . . . . . . . . . . . . . . . . . . . .215
EGG . . . . . . . . . . . . . . . . . . . . . . . . .215
EGJ . . . . . . . . . . . . . . . . . . . . . . . . .215
EGK . . . . . . . . . . . . . . . . . . . . . . . . .215
EGN . . . . . . . . . . . . . . . . . . . . . . . . .215
EGR . . . . . . . . . . . . . . . . . . . . . . . . .215
EGT . . . . . . . . . . . . . . . . . . . . . . . . .215
EGW 64535 . . . . . . . . . . . . . . . . . . .215
EHA . . . . . . . . . . . . . . . . . . . . . . . . .211
EHC/EHB . . . . . . . . . . . . . . . . . . . . .215
EHD . . . . . . . . . . . . . . . . . . . . . . . . .216
EHE 64626 HLX . . . . . . . . . . . . . . . .211
EHF . . . . . . . . . . . . . . . . . . . . . . . . .216
EHG . . . . . . . . . . . . . . . . . . . . . . . . .216
EHJ 64655 HLX . . . . . . . . . . . . . . . .211
EHJ 64655 HLX BULK . . . . . . . . . . .211
EHJ 64655 HLX/7X . . . . . . . . . . . . .211
EHP . . . . . . . . . . . . . . . . . . . . . . . . .216
EHR . . . . . . . . . . . . . . . . . . . . . . . . .216
EJA . . . . . . . . . . . . . . . . . . . . . . . . . .211
EJG . . . . . . . . . . . . . . . . . . . . . . . . .216
EJL . . . . . . . . . . . . . . . . . . . . . . . . . .211
EJM . . . . . . . . . . . . . . . . . . . . . . . . .211
EJV . . . . . . . . . . . . . . . . . . . . . . . . . .211
EKB . . . . . . . . . . . . . . . . . . . . . . . . .216
EKE . . . . . . . . . . . . . . . . . . . . . . . . .212
EKE/X . . . . . . . . . . . . . . . . . . . . . . . .212
EKP/ENA . . . . . . . . . . . . . . . . . . . . .212
ELC . . . . . . . . . . . . . . . . . . . . . . . . .212
ELC 64653 HLX . . . . . . . . . . . . . . . .212
ELC-10 64659 HLX . . . . . . . . . . . . .212
ELC-3/X . . . . . . . . . . . . . . . . . . . . . .212
ELC-7/X . . . . . . . . . . . . . . . . . . . . . .212
ELC-7/X BULK . . . . . . . . . . . . . . . . .212
ELC-HL . . . . . . . . . . . . . . . . . . . . . . .212
ELD . . . . . . . . . . . . . . . . . . . . . . . . .212
ELH . . . . . . . . . . . . . . . . . . . . . . . . .212
ENG . . . . . . . . . . . . . . . . . . . . . . . . .212
ENH . . . . . . . . . . . . . . . . . . . . . . . . .212
ENH SPOT . . . . . . . . . . . . . . . . . . . .212
ENH-5 . . . . . . . . . . . . . . . . . . . . . . .212
ENL . . . . . . . . . . . . . . . . . . . . . . . . .212
ENX . . . . . . . . . . . . . . . . . . . . . . . . .212
ENX-5 . . . . . . . . . . . . . . . . . . . . . . . .212
ENX-7 . . . . . . . . . . . . . . . . . . . . . . . .212
Page Type
EPT . . . . . . . . . . . . . . . . . . . . . . . . .212
EPX . . . . . . . . . . . . . . . . . . . . . . . . .212
EPZ . . . . . . . . . . . . . . . . . . . . . . . . .212
ESA/FHD 64225 . . . . . . . . . . . . . . . .212
ESB 64250 HLX . . . . . . . . . . . . . . . .212
ETJ . . . . . . . . . . . . . . . . . . . . . . . . . .212
EVA 64623 HLX . . . . . . . . . . . . . . . .212
EVC 64657 HLX . . . . . . . . . . . . . . . .212
EVD 64663 HLX . . . . . . . . . . . . . . . .212
EVW . . . . . . . . . . . . . . . . . . . . . . . . .212
EXC/230 . . . . . . . . . . . . . . . . . . . . . .218
EXC/240 . . . . . . . . . . . . . . . . . . . . . .218
EXD/230 . . . . . . . . . . . . . . . . . . . . . .218
EXD/240 . . . . . . . . . . . . . . . . . . . . . .218
EXE/230 . . . . . . . . . . . . . . . . . . . . . .218
EXE/240 . . . . . . . . . . . . . . . . . . . . . .218
EXR . . . . . . . . . . . . . . . . . . . . . . . . .212
EXW . . . . . . . . . . . . . . . . . . . . . . . . .212
EXY . . . . . . . . . . . . . . . . . . . . . . . . .212
EYB . . . . . . . . . . . . . . . . . . . . . . . . .213
EYB-5 . . . . . . . . . . . . . . . . . . . . . . . .213
EYB-7 . . . . . . . . . . . . . . . . . . . . . . . .213
EZE . . . . . . . . . . . . . . . . . . . . . . . . . .213
FAD . . . . . . . . . . . . . . . . . . . . . . . . .216
FAL . . . . . . . . . . . . . . . . . . . . . . . . . .216
FCB . . . . . . . . . . . . . . . . . . . . . . . . .216
FCM . . . . . . . . . . . . . . . . . . . . . . . . .216
FCR 64625 HLX . . . . . . . . . . . . . . . .213
FCS 64640 HLX . . . . . . . . . . . . . . . .213
FDA . . . . . . . . . . . . . . . . . . . . . . . . .216
FDB . . . . . . . . . . . . . . . . . . . . . . . . .216
FDN . . . . . . . . . . . . . . . . . . . . . . . . .216
FDS/DZE 64643 . . . . . . . . . . . . . . . .213
FDT 64628 . . . . . . . . . . . . . . . . . . . .213
FDV 64642 HLX . . . . . . . . . . . . . . . .213
FEL . . . . . . . . . . . . . . . . . . . . . . . . . .216
FEP/240 . . . . . . . . . . . . . . . . . . . . . .216
FER . . . . . . . . . . . . . . . . . . . . . . . . .216
FEV . . . . . . . . . . . . . . . . . . . . . . . . . .216
FEX/230 . . . . . . . . . . . . . . . . . . . . . .216
FEX/240 . . . . . . . . . . . . . . . . . . . . . .216
FEY . . . . . . . . . . . . . . . . . . . . . . . . . .216
FFJ . . . . . . . . . . . . . . . . . . . . . . . . . .216
FFM . . . . . . . . . . . . . . . . . . . . . . . . .216
FFN . . . . . . . . . . . . . . . . . . . . . . . . . .218
FFP . . . . . . . . . . . . . . . . . . . . . . . . . .218
FFR . . . . . . . . . . . . . . . . . . . . . . . . . .218
FFS . . . . . . . . . . . . . . . . . . . . . . . . . .219
FFT . . . . . . . . . . . . . . . . . . . . . . . . . .216
FHM . . . . . . . . . . . . . . . . . . . . . . . . .216
FHS . . . . . . . . . . . . . . . . . . . . . . . . .213
FKJ CP/71 . . . . . . . . . . . . . . . . . . . .216
FKK CP/73 . . . . . . . . . . . . . . . . . . . .216
FKT/EYH . . . . . . . . . . . . . . . . . . . . . .213
FKW . . . . . . . . . . . . . . . . . . . . . . . . .216
FLE . . . . . . . . . . . . . . . . . . . . . . . . . .213
FLK . . . . . . . . . . . . . . . . . . . . . . . . . .216
FLK PLUS HPR 575/115 . . . . . . . . .216
FLK/X 115V . . . . . . . . . . . . . . . . . . .216
FMR . . . . . . . . . . . . . . . . . . . . . . . . .216
FNS 64512 . . . . . . . . . . . . . . . . . . . .213
FNT 64656 HLX . . . . . . . . . . . . . . . .213
FRG . . . . . . . . . . . . . . . . . . . . . . . . .216
FRK . . . . . . . . . . . . . . . . . . . . . . . . .216
FRL CP/89 . . . . . . . . . . . . . . . . . . . .216
FRN 2000T7Q . . . . . . . . . . . . . . . . .219
FSH . . . . . . . . . . . . . . . . . . . . . . . . .216
FSX/230 . . . . . . . . . . . . . . . . . . . . . .213
FSY . . . . . . . . . . . . . . . . . . . . . . . . .213
FTK . . . . . . . . . . . . . . . . . . . . . . . . . .216
FVL . . . . . . . . . . . . . . . . . . . . . . . . . .216
FVM . . . . . . . . . . . . . . . . . . . . . . . . .216
FXL . . . . . . . . . . . . . . . . . . . . . . . . . .213
FXL-HL . . . . . . . . . . . . . . . . . . . . . . .213
GCA . . . . . . . . . . . . . . . . . . . . . . . . .216
GCB . . . . . . . . . . . . . . . . . . . . . . . . .213
GLC 575/115/300 . . . . . . . . . . . . . . .217
GLA 575/115/2000 . . . . . . . . . . . . . .216
GLD 750/115/300 . . . . . . . . . . . . . .217
GLE 750/115/1500 . . . . . . . . . . . . . .217
GLF . . . . . . . . . . . . . . . . . . . . . . . . .217
HBO 50 W AC L1 . . . . . . . . . . . . . . .254
HBO 50 W AC L2 . . . . . . . . . . . . . . .254
Page
HBO 50 W/3 . . . . . . . . . . . . . . . . . . .254
HBO 100 W/2 . . . . . . . . . . . . . . . . . .254
HBO 103 W/2 . . . . . . . . . . . . . . . . . .254
HBO R 103 W/45 . . . . . . . . . . . . . . .255
HBO 200 W/2 L1 . . . . . . . . . . . . . . .255
HBO 200 W/2 L2 . . . . . . . . . . . . . . .255
HBO 200 W/2 TM L2 . . . . . . . . . . . .255
HBO 200 W/4 . . . . . . . . . . . . . . . . . .255
HBO 200 W/DC . . . . . . . . . . . . . . . .256
HBO 200 W/DC TM . . . . . . . . . . . . .256
HBO 200 W/DN-I . . . . . . . . . . . . . . .258
HBO 201 W/HS-D2 . . . . . . . . . . . . .258
HBO 202 W/4 . . . . . . . . . . . . . . . . . .256
HBO 250 W/BY . . . . . . . . . . . . . . . .258
HBO 250 W/HS . . . . . . . . . . . . . . . .258
HBO 350 W . . . . . . . . . . . . . . . . . . .259
HBO 350 W/S . . . . . . . . . . . . . . . . . .259
HBO 450 W/GS . . . . . . . . . . . . . . . .259
HBO 500 W/A . . . . . . . . . . . . . . . . . .259
HBO 500 W/B . . . . . . . . . . . . . . . . . .259
HBO 510 W/FU . . . . . . . . . . . . . . . . .258
HBO 1000 W/CEL . . . . . . . . . . . . . . .260
HBO 1000 W/D . . . . . . . . . . . . . . . .261
HBO 1000 W/NEL . . . . . . . . . . . . . .260
HBO 1002 W/CEL . . . . . . . . . . . . . . .260
HBO 1002 W/NEL . . . . . . . . . . . . . .260
HBO 1002 W/NIL . . . . . . . . . . . . . . .260
HBO 1003 W/PI . . . . . . . . . . . . . . . .261
HBO 1003 W/PIL . . . . . . . . . . . . . . .261
HBO 1500 W/CIEL . . . . . . . . . . . . . .261
HBO 1500 W/CIL . . . . . . . . . . . . . . .261
HBO 1500 W/PI . . . . . . . . . . . . . . . .262
HBO 1500 W/PIL . . . . . . . . . . . . . . .262
HBO 1500 W/PIL HP . . . . . . . . . . . .262
HBO 2000 W/NIL . . . . . . . . . . . . . . .262
HBO 2001 W/CIEL . . . . . . . . . . . . . .263
HBO 2001 W/CIL . . . . . . . . . . . . . . .263
HBO 2001 W/NIEL . . . . . . . . . . . . . .262
HBO 2001 W/NIL . . . . . . . . . . . . . . .263
HBO 2002 W/MA . . . . . . . . . . . . . . .263
HBO 2002 W/MAL . . . . . . . . . . . . . .264
HBO 2002 W/NIL . . . . . . . . . . . . . . .263
HBO 2011 W/NIL . . . . . . . . . . . . . . .264
HBO 2500 W/PIL . . . . . . . . . . . . . . .264
HBO 2501 W/NIL . . . . . . . . . . . . . . .264
HBO 2510 W/NIL . . . . . . . . . . . . . . .264
HBO 2700 W/CIL . . . . . . . . . . . . . . .265
HBO 3500 W/HK . . . . . . . . . . . . . . .266
HBO 3500 W/NIL . . . . . . . . . . . . . . .265
HBO 3500 W/PI . . . . . . . . . . . . . . . .265
HBO 3500 W/PIL . . . . . . . . . . . . . . .265
HBO 3501 W/PI . . . . . . . . . . . . . . . .265
HBO 3501 W/PIL . . . . . . . . . . . . . . .266
HBO 4500 W/CIL . . . . . . . . . . . . . . .266
HBO 5000 W/HK . . . . . . . . . . . . . . .267
HBO 5000 W/TA . . . . . . . . . . . . . . . .266
HBO 5001 W/UF . . . . . . . . . . . . . . . .266
HBO 5500 W/PI . . . . . . . . . . . . . . . .267
HMI 200 W/SE . . . . . . . . . . . . . . . . .225
HMI 250 W/SE . . . . . . . . . . . . . . . . .225
HMI 400 W/SE . . . . . . . . . . . . . . . . .225
HMI 575 W/DXS . . . . . . . . . . . . . . .227
HMI 575 W/GS . . . . . . . . . . . . . . . . .227
HMI 575 W/SEL XS . . . . . . . . . . . . .225
HMI 700 W/SE XS . . . . . . . . . . . . . .225
HMI 1200 W/DXS . . . . . . . . . . . . . .227
HMI 1200 W/GS . . . . . . . . . . . . . . . .227
HMI 1200 W/S XS . . . . . . . . . . . . . .227
HMI 1200 W/SEL XS . . . . . . . . . . . .225
HMI 2500 W/DXS . . . . . . . . . . . . . .227
HMI 2500 W/S XS . . . . . . . . . . . . . .227
HMI 2500 W/SE XS . . . . . . . . . . . . .226
HMI 4000 W . . . . . . . . . . . . . . . . . .227
HMI 4000 W/DXS . . . . . . . . . . . . . .227
HMI 4000 W/SE XS . . . . . . . . . . . . .226
HMI 6000 W . . . . . . . . . . . . . . . . . .228
HMI 6000 W/DXS . . . . . . . . . . . . . .228
HMI 6000 W/SE XS . . . . . . . . . . . . .226
HMI 12000 W/DXS . . . . . . . . . . . . .228
HMI 12000 W/SE XS . . . . . . . . . . . .226
HMI 12000 W/XS . . . . . . . . . . . . . . .228
HMI 12000 W/SE/GX51 . . . . . . . . . .226
HMI 18000 W/DXS . . . . . . . . . . . . .228
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Index by Ordering
Abreviation (cont.)
Type
Page 283
Type
Page
HMI 18000 W/SE/GX51 . . . . . . . . . .226
HPL 375/115 (UCF) . . . . . . . . . . . . .217
HPL 375/115/X (UCF) . . . . . . . . . . .217
HPL 550/77 (UCF) . . . . . . . . . . . . . .217
HPL 550/77/X (UCF) . . . . . . . . . . . .217
HPL 575/115 (UCF) . . . . . . . . . . . . .217
HPL 575/115/X (UCF) . . . . . . . . . . .217
HPL 575/120 (UCF) . . . . . . . . . . . . .217
HPL 575/120/X (UCF) . . . . . . . . . . .217
HPL 575/230 (UCF) . . . . . . . . . . . . .217
HPL 575/230/X (UCF) . . . . . . . . . . .217
HPL 575/240 (UCF) . . . . . . . . . . . . .217
HPL 575/240/X (UCF) . . . . . . . . . . .217
HPL 750/77 (UCF) . . . . . . . . . . . . . .217
HPL 750/115 (UCF) . . . . . . . . . . . . .217
HPL 750/115/X (UCF) . . . . . . . . . . .217
HPL 750/120 (UCF) . . . . . . . . . . . . .217
HPL 750/120/X (UCF) . . . . . . . . . . .217
HPL 750/230 (UCF) . . . . . . . . . . . . .217
HPL 750/230/X (UCF) . . . . . . . . . . .217
HPL 750/240 (UCF) . . . . . . . . . . . . .217
HPL 750/240/X (UCF) . . . . . . . . . . .217
HSD 150W/70 4ARXS . . . . . . . . . . .236
HSD 150W/UL/75 4ARXS . . . . . . . .236
HSD 200W/60 4ARXS . . . . . . . . . . .236
HSD 250W/60 4ARXS . . . . . . . . . . .236
HSD 250W/80 4ARXS . . . . . . . . . . .236
HSD 250W/UL/75 4ARXS . . . . . . . .236
HSD 575W/60 4ARXS . . . . . . . . . . .236
HSD 575W/72 4ARXS . . . . . . . . . . .236
HSD 575W/UL/75 4ARXS . . . . . . . .236
HSR 400/60 . . . . . . . . . . . . . . . . . . .235
HSR 575/60 . . . . . . . . . . . . . . . . . . .235
HSR 575/72 . . . . . . . . . . . . . . . . . . .235
HSR 700/60 . . . . . . . . . . . . . . . . . . .235
HSR 1200/60 . . . . . . . . . . . . . . . . . .235
HTI S 35/12 . . . . . . . . . . . . . . . . . . .229
HTI 150 W . . . . . . . . . . . . . . . . . . . .229
HTI 152 W . . . . . . . . . . . . . . . . . . . .229
HTI 250 W/22 . . . . . . . . . . . . . . . . .234
HTI 250 W/32 . . . . . . . . . . . . . . . . .234
HTI 250 W/32C . . . . . . . . . . . . . . . .234
HTI 250W/D5/80 BABY SHARXS . . .232
HTI 300 W/DX . . . . . . . . . . . . . . . . .233
HTI 300W/D5/57 BABY SHARXS . . .232
HTI 300W/D5/65 BABY SHARXS . . .232
HTI 400 W/24 . . . . . . . . . . . . . . . . .234
HTI 400W/D3/75 SHARXS . . . . . . . .230
HTI 400W/D3/75 SHARXS BULK . . .230
HTI 400W/D5/60 BABY SHARXS . . 232
HTI 403 W/24 . . . . . . . . . . . . . . . . .234
HTI 405 W/SE XS . . . . . . . . . . . . . . .229
HTI 575W/D4/60 SHARXS . . . . . . . .230
HTI 575W/D4/75 SHARXS . . . . . . . .230
HTI 575W/D5/56 BABY SHARXS . . .232
HTI 600 W/SE . . . . . . . . . . . . . . . . .229
HTI 700 W/SE/75 . . . . . . . . . . . . . . .229
HTI 700W/D4/60 SHARXS . . . . . . . .230
HTI 700W/D4/60 SHARXS BULK . . .230
HTI 700W/D4/75 SHARXS . . . . . . . .231
HTI 700W/D4/75 SHARXS BULK . . .231
HTI 705 W/SE XS . . . . . . . . . . . . . . .229
HTI 1200 W/SE XS . . . . . . . . . . . . . .229
HTI 1200W/D7/60 SHARXS . . . . . . .231
HTI 1200W/D7/60 SHARXS BULK . .231
HTI 1200W/D7/75 SHARXS . . . . . . .231
HTI 1500W/D7/60 SHARXS . . . . . . .231
HTI 1800W/SE XS . . . . . . . . . . . . . .229
HTI 2500 W/DEL . . . . . . . . . . . . . . .233
HTI 2500 W/SE XS . . . . . . . . . . . . . .229
HTI 4000 W/DE . . . . . . . . . . . . . . . .233
HWLV 1200W/80V . . . . . . . . . . . . . .217
HWMV 1200W/115V . . . . . . . . . . . .217
HWHV 1200W/220V . . . . . . . . . . . .217
HXP R 120 W/17C . . . . . . . . . . . . . .257
HXP R 120 W/45 C UV . . . . . . . . . .257
HXP R 120 W/45 C VIS . . . . . . . . . .257
JCP 650W/100V . . . . . . . . . . . . . . . .215
LX24T3/956/A4 . . . . . . . . . . . . . . . .270
LX40T3/956/A3 . . . . . . . . . . . . . . . .270
Page Type
Na 10 FL . . . . . . . . . . . . . . . . . . . . .269
Na/10 . . . . . . . . . . . . . . . . . . . . . . . .269
Q4559 . . . . . . . . . . . . . . . . . . . . . . .220
Q4559X . . . . . . . . . . . . . . . . . . . . . .220
Q4681 . . . . . . . . . . . . . . . . . . . . . . .220
QXL 750/77 . . . . . . . . . . . . . . . . . . .218
QXL 750/77/X . . . . . . . . . . . . . . . . .218
STUDIOLINE 55W/3200 . . . . . . . . . .218
STUDIOLINE 55W/5600 . . . . . . . . . .218
VIP R 273/45 . . . . . . . . . . . . . . . . . .268
XBO 75 W/2 . . . . . . . . . . . . . . . . . . .237
XBO 75 W/2 OFR . . . . . . . . . . . . . . .237
XBO 100 W OFR . . . . . . . . . . . . . . .237
XBO R 100 W/45 OFR . . . . . . . . . . .237
XBO R 100 W/45C OFR . . . . . . . . . .237
XBO R 101 W/45C OFR . . . . . . . . . .238
XBO 150 W/1 . . . . . . . . . . . . . . . . . .238
XBO 150 W/1 OFR . . . . . . . . . . . . . .238
XBO 150 W/4 . . . . . . . . . . . . . . . . . .238
XBO 150 W/CR OFR . . . . . . . . . . . . .238
XBO 150 W/S . . . . . . . . . . . . . . . . . .239
XBO R 180 W/45/OFR . . . . . . . . . . .239
XBO R 180 W/45C OFR . . . . . . . . . .239
XBO R 181 W/45C OFR . . . . . . . . . .239
XBO R 300 W/60C OFR . . . . . . . . . .239
XBO 450 W . . . . . . . . . . . . . . . . . . .240
XBO 450 W OFR . . . . . . . . . . . . . . .240
XBO 450 W/1 . . . . . . . . . . . . . . . . . .240
XBO 450 W/2 OFR . . . . . . . . . . . . . .240
XBO 450 W/4 . . . . . . . . . . . . . . . . . .240
XBO 500 W/H OFR . . . . . . . . . . . . . .241
XBO 700 W/HS OFR . . . . . . . . . . . . .241
XBO 900 W OFR . . . . . . . . . . . . . . .241
XBO 1000 W/HS OFR . . . . . . . . . . . .241
XBO 1000 W/HSC OFR . . . . . . . . . .241
XBO 1000 W/HTP OFR . . . . . . . . . . .242
XBO 1600 W OFR . . . . . . . . . . . . . .242
XBO 1600 W/CA OFR . . . . . . . . . . . .242
XBO 1600 W/HS OFR . . . . . . . . . . . .242
XBO 1600 W/HSC OFR . . . . . . . . . .242
XBO 2000 W/DTP OFR . . . . . . . . . . .243
XBO 2000 W/H CL OFR . . . . . . . . . .243
XBO 2000 W/H OFR . . . . . . . . . . . . .243
XBO 2000 W/H XL OFR . . . . . . . . . .243
XBO 2000 W/HCC OFR . . . . . . . . . .243
XBO 2000 W/HPS OFR . . . . . . . . . .244
XBO 2000 W/HS OFR . . . . . . . . . . . .244
XBO 2000 W/HTP OFR . . . . . . . . . . .244
XBO 2000 W/SHSC OFR . . . . . . . . .244
XBO 2001 W/HTP OFR . . . . . . . . . . .244
XBO 2500 W OFR . . . . . . . . . . . . . .245
XBO 2500 W/HS OFR . . . . . . . . . . . .245
XBO 2500 W/HTP OFR . . . . . . . . . . .245
XBO 3000 W/DHP OFR . . . . . . . . . .245
XBO 3000 W/DHS OFR . . . . . . . . . .245
XBO 3000 W/DTP OFR . . . . . . . . . . .246
XBO 3000 W/H CL OFR . . . . . . . . . .246
XBO 3000 W/H OFR . . . . . . . . . . . . .246
XBO 3000 W/H XL OFR . . . . . . . . . .246
XBO 3000 W/HPS OFR . . . . . . . . . .246
XBO 3000 W/HS CL OFR . . . . . . . . .247
XBO 3000 W/HS OFR . . . . . . . . . . . .247
XBO 3000 W/HS XL OFR . . . . . . . . .247
XBO 3000 W/HSLA OFR . . . . . . . . .247
XBO 3000 W/HTP OFR . . . . . . . . . . .247
XBO 4000 W/DHP OFR . . . . . . . . . .248
XBO 4000 W/HS CL OFR . . . . . . . . .248
XBO 4000 W/HS OFR . . . . . . . . . . . .248
XBO 4000 W/HS XL OFR . . . . . . . . .248
XBO 4000 W/HTP OFR . . . . . . . . . . .248
XBO 4200 W/CA OFR . . . . . . . . . . . .249
XBO 4200 W/GS OFR . . . . . . . . . . . .249
XBO 4200 W/HPS OFR . . . . . . . . . .249
XBO 4500 W/DHP OFR . . . . . . . . . .249
XBO 4500 W/DTP OFR . . . . . . . . . . .249
XBO 4500 W/HS OFR . . . . . . . . . . . .250
XBO 4500 W/HSLA OFR . . . . . . . . .250
XBO 4500 W/HTP OFR . . . . . . . . . . .250
XBO 5000 W/H OFR . . . . . . . . . . . . .250
XBO 5000 W/HTP OFR . . . . . . . . . . .250
XBO 6000 W/DHP OFR . . . . . . . . . .251
XBO 6000 W/DTP OFR . . . . . . . . . . .251
XBO 6000 W/HS OFR . . . . . . . . . . . .251
For more complete product information visit www.sylvania.com
Page
XBO 6000 W/HSLA OFR . . . . . . . . .251
XBO 6000 W/HTP OFR . . . . . . . . . . .251
XBO 6500 W/DHP OFR . . . . . . . . . .252
XBO 6500 W/HSLA OFR . . . . . . . . .252
XBO 7000 W/HS OFR . . . . . . . . . . . .252
XBO 8000 W/HS OFR . . . . . . . . . . . .252
XERADEX 20 . . . . . . . . . . . . . . . . . .270
XERADEX 20/HV . . . . . . . . . . . . . . .270
XERADEX 20/SY45/45 . . . . . . . . . . .270
Xstage 2000W OFR . . . . . . . . . . . . .253
Xstage 3000W OFR . . . . . . . . . . . . .253
Xstage 4000W OFR . . . . . . . . . . . . .253
Xstage 7000W OFR . . . . . . . . . . . . .253
Index by Product Number
Type
Type
Page
Page 54214 . . . . . . . . . . . . . . . . . . . . . . . .214
11558 . . . . . . . . . . . . . . . . . . . . . . . .211
11560 . . . . . . . . . . . . . . . . . . . . . . . .211
11619 . . . . . . . . . . . . . . . . . . . . . . . .211
11624 . . . . . . . . . . . . . . . . . . . . . . . .217
11625 . . . . . . . . . . . . . . . . . . . . . . . .217
11655 . . . . . . . . . . . . . . . . . . . . . . . .215
11656 . . . . . . . . . . . . . . . . . . . . . . . .217
11657 . . . . . . . . . . . . . . . . . . . . . . . .217
13365 . . . . . . . . . . . . . . . . . . . . . . . .211
14936 . . . . . . . . . . . . . . . . . . . . . . . .220
14974 . . . . . . . . . . . . . . . . . . . . . . . .219
14988 . . . . . . . . . . . . . . . . . . . . . . . .220
14994 . . . . . . . . . . . . . . . . . . . . . . . .220
15399 . . . . . . . . . . . . . . . . . . . . . . . .220
17980 . . . . . . . . . . . . . . . . . . . . . . . .220
17981 . . . . . . . . . . . . . . . . . . . . . . . .220
20607 . . . . . . . . . . . . . . . . . . . . . . . .218
20608 . . . . . . . . . . . . . . . . . . . . . . . .218
52079 . . . . . . . . . . . . . . . . . . . . . . . .270
52155 . . . . . . . . . . . . . . . . . . . . . . . .270
53997 . . . . . . . . . . . . . . . . . . . . . . . .215
53999 . . . . . . . . . . . . . . . . . . . . . . . .214
54001 . . . . . . . . . . . . . . . . . . . . . . . .217
54021 . . . . . . . . . . . . . . . . . . . . . . . .214
54022 . . . . . . . . . . . . . . . . . . . . . . . .214
54028 . . . . . . . . . . . . . . . . . . . . . . . .214
54032 . . . . . . . . . . . . . . . . . . . . . . . .214
54032 . . . . . . . . . . . . . . . . . . . . . . . .219
54038 . . . . . . . . . . . . . . . . . . . . . . . .211
54044 . . . . . . . . . . . . . . . . . . . . . . . .213
54050 . . . . . . . . . . . . . . . . . . . . . . . .214
54061 . . . . . . . . . . . . . . . . . . . . . . . .225
54062 . . . . . . . . . . . . . . . . . . . . . . . .225
54063 . . . . . . . . . . . . . . . . . . . . . . . .225
54066 . . . . . . . . . . . . . . . . . . . . . . . .227
54067 . . . . . . . . . . . . . . . . . . . . . . . .225
54068 . . . . . . . . . . . . . . . . . . . . . . . .227
54070 . . . . . . . . . . . . . . . . . . . . . . . .226
54071 . . . . . . . . . . . . . . . . . . . . . . . .227
54073 . . . . . . . . . . . . . . . . . . . . . . . .228
54074 . . . . . . . . . . . . . . . . . . . . . . . .228
54078 . . . . . . . . . . . . . . . . . . . . . . . .229
54079 . . . . . . . . . . . . . . . . . . . . . . . .229
54080 . . . . . . . . . . . . . . . . . . . . . . . .234
54081 . . . . . . . . . . . . . . . . . . . . . . . .234
54083 . . . . . . . . . . . . . . . . . . . . . . . .234
54087 . . . . . . . . . . . . . . . . . . . . . . . .229
54088 . . . . . . . . . . . . . . . . . . . . . . . .227
54089 . . . . . . . . . . . . . . . . . . . . . . . .234
54098 . . . . . . . . . . . . . . . . . . . . . . . .227
54099 . . . . . . . . . . . . . . . . . . . . . . . .226
54102 . . . . . . . . . . . . . . . . . . . . . . . .235
54104 . . . . . . . . . . . . . . . . . . . . . . . .234
54107 . . . . . . . . . . . . . . . . . . . . . . . .235
54113 . . . . . . . . . . . . . . . . . . . . . . . .226
54115 . . . . . . . . . . . . . . . . . . . . . . . .235
54116 . . . . . . . . . . . . . . . . . . . . . . . .235
54121 . . . . . . . . . . . . . . . . . . . . . . . .214
54122 . . . . . . . . . . . . . . . . . . . . . . . .214
54123 . . . . . . . . . . . . . . . . . . . . . . . .211
54124 . . . . . . . . . . . . . . . . . . . . . . . .214
54125 . . . . . . . . . . . . . . . . . . . . . . . .214
54126 . . . . . . . . . . . . . . . . . . . . . . . .211
54129 . . . . . . . . . . . . . . . . . . . . . . . .236
54130 . . . . . . . . . . . . . . . . . . . . . . . .229
54133 . . . . . . . . . . . . . . . . . . . . . . . .233
54137 . . . . . . . . . . . . . . . . . . . . . . . .225
54138 . . . . . . . . . . . . . . . . . . . . . . . .214
54139 . . . . . . . . . . . . . . . . . . . . . . . .229
54141 . . . . . . . . . . . . . . . . . . . . . . . .229
54142 . . . . . . . . . . . . . . . . . . . . . . . .229
54143 . . . . . . . . . . . . . . . . . . . . . . . .233
54167 . . . . . . . . . . . . . . . . . . . . . . . .236
54168 . . . . . . . . . . . . . . . . . . . . . . . .235
54170 . . . . . . . . . . . . . . . . . . . . . . . .236
54189 . . . . . . . . . . . . . . . . . . . . . . . .211
54192 . . . . . . . . . . . . . . . . . . . . . . . .211
54202 . . . . . . . . . . . . . . . . . . . . . . . .231
54210 . . . . . . . . . . . . . . . . . . . . . . . .211
54211 . . . . . . . . . . . . . . . . . . . . . . . .211
54212 . . . . . . . . . . . . . . . . . . . . . . . .212
54231 . . . . . . . . . . . . . . . . . . . . . . . .211
54232 . . . . . . . . . . . . . . . . . . . . . . . .217
54233 . . . . . . . . . . . . . . . . . . . . . . . .214
54241 . . . . . . . . . . . . . . . . . . . . . . . .230
54242 . . . . . . . . . . . . . . . . . . . . . . . .231
54243 . . . . . . . . . . . . . . . . . . . . . . . .236
54245 . . . . . . . . . . . . . . . . . . . . . . . .214
54246 . . . . . . . . . . . . . . . . . . . . . . . .213
54247 . . . . . . . . . . . . . . . . . . . . . . . .214
54248 . . . . . . . . . . . . . . . . . . . . . . . .213
54249 . . . . . . . . . . . . . . . . . . . . . . . .211
54250 . . . . . . . . . . . . . . . . . . . . . . . .211
54251 . . . . . . . . . . . . . . . . . . . . . . . .212
54252 . . . . . . . . . . . . . . . . . . . . . . . .214
54253 . . . . . . . . . . . . . . . . . . . . . . . .213
54254 . . . . . . . . . . . . . . . . . . . . . . . .211
54255 . . . . . . . . . . . . . . . . . . . . . . . .212
54256 . . . . . . . . . . . . . . . . . . . . . . . .213
54257 . . . . . . . . . . . . . . . . . . . . . . . .214
54258 . . . . . . . . . . . . . . . . . . . . . . . .214
54259 . . . . . . . . . . . . . . . . . . . . . . . .212
54260 . . . . . . . . . . . . . . . . . . . . . . . .212
54261 . . . . . . . . . . . . . . . . . . . . . . . .212
54262 . . . . . . . . . . . . . . . . . . . . . . . .214
54263 . . . . . . . . . . . . . . . . . . . . . . . .213
54264 . . . . . . . . . . . . . . . . . . . . . . . .213
54265 . . . . . . . . . . . . . . . . . . . . . . . .227
54268 . . . . . . . . . . . . . . . . . . . . . . . .231
54269 . . . . . . . . . . . . . . . . . . . . . . . .231
54270 . . . . . . . . . . . . . . . . . . . . . . . .230
54271 . . . . . . . . . . . . . . . . . . . . . . . .236
54272 . . . . . . . . . . . . . . . . . . . . . . . .211
54273 . . . . . . . . . . . . . . . . . . . . . . . .214
54274 . . . . . . . . . . . . . . . . . . . . . . . .214
54275 . . . . . . . . . . . . . . . . . . . . . . . .214
54276 . . . . . . . . . . . . . . . . . . . . . . . .213
54277 . . . . . . . . . . . . . . . . . . . . . . . .213
54278 . . . . . . . . . . . . . . . . . . . . . . . .214
54280 . . . . . . . . . . . . . . . . . . . . . . . .230
54281 . . . . . . . . . . . . . . . . . . . . . . . .231
54282 . . . . . . . . . . . . . . . . . . . . . . . .230
54283 . . . . . . . . . . . . . . . . . . . . . . . .230
54287 . . . . . . . . . . . . . . . . . . . . . . . .236
54288 . . . . . . . . . . . . . . . . . . . . . . . .236
54289 . . . . . . . . . . . . . . . . . . . . . . . .226
54296 . . . . . . . . . . . . . . . . . . . . . . . .230
54297 . . . . . . . . . . . . . . . . . . . . . . . .232
54298 . . . . . . . . . . . . . . . . . . . . . . . .232
54299 . . . . . . . . . . . . . . . . . . . . . . . .232
54300 . . . . . . . . . . . . . . . . . . . . . . . .232
54301 . . . . . . . . . . . . . . . . . . . . . . . .214
54302 . . . . . . . . . . . . . . . . . . . . . . . .214
54303 . . . . . . . . . . . . . . . . . . . . . . . .214
54310 . . . . . . . . . . . . . . . . . . . . . . . .225
54311 . . . . . . . . . . . . . . . . . . . . . . . .236
54312 . . . . . . . . . . . . . . . . . . . . . . . .236
54313 . . . . . . . . . . . . . . . . . . . . . . . .227
54314 . . . . . . . . . . . . . . . . . . . . . . . .227
54315 . . . . . . . . . . . . . . . . . . . . . . . .228
54316 . . . . . . . . . . . . . . . . . . . . . . . .228
54317 . . . . . . . . . . . . . . . . . . . . . . . .228
54319 . . . . . . . . . . . . . . . . . . . . . . . .231
54321 . . . . . . . . . . . . . . . . . . . . . . . .226
54329 . . . . . . . . . . . . . . . . . . . . . . . .229
54350 . . . . . . . . . . . . . . . . . . . . . . . .216
54354 . . . . . . . . . . . . . . . . . . . . . . . .214
54356 . . . . . . . . . . . . . . . . . . . . . . . .214
54357 . . . . . . . . . . . . . . . . . . . . . . . .226
54359 . . . . . . . . . . . . . . . . . . . . . . . .232
54366 . . . . . . . . . . . . . . . . . . . . . . . .212
54383 . . . . . . . . . . . . . . . . . . . . . . . .213
54386 . . . . . . . . . . . . . . . . . . . . . . . .213
54387 . . . . . . . . . . . . . . . . . . . . . . . .216
54388 . . . . . . . . . . . . . . . . . . . . . . . .212
54392 . . . . . . . . . . . . . . . . . . . . . . . .212
54394 . . . . . . . . . . . . . . . . . . . . . . . .212
54399 . . . . . . . . . . . . . . . . . . . . . . . .233
54400 . . . . . . . . . . . . . . . . . . . . . . . .213
54409 . . . . . . . . . . . . . . . . . . . . . . . .211
54411 . . . . . . . . . . . . . . . . . . . . . . . .211
54412 . . . . . . . . . . . . . . . . . . . . . . . .216
54428 . . . . . . . . . . . . . . . . . . . . . . . .216
Symbols/Footnotes on page 275-281
283
D
I
S
P
L
A
Y
O
P
T
I
C
I
N
D
E
X
071_DO_drop.qxd
12/13/07
Index by Product Number
(continued)
Type
D
I
S
P
L
A
Y
O
P
T
I
C
I
N
D
E
X
Page
54430 . . . . . . . . . . . . . . . . . . . . . . . .213
54435 . . . . . . . . . . . . . . . . . . . . . . . .216
54436 . . . . . . . . . . . . . . . . . . . . . . . .216
54441 . . . . . . . . . . . . . . . . . . . . . . . .216
54442 . . . . . . . . . . . . . . . . . . . . . . . .216
54446 . . . . . . . . . . . . . . . . . . . . . . . .213
54448 . . . . . . . . . . . . . . . . . . . . . . . .213
54455 . . . . . . . . . . . . . . . . . . . . . . . .213
54459 . . . . . . . . . . . . . . . . . . . . . . . .216
54460 . . . . . . . . . . . . . . . . . . . . . . . .217
54466 . . . . . . . . . . . . . . . . . . . . . . . .213
54471 . . . . . . . . . . . . . . . . . . . . . . . .216
54483 . . . . . . . . . . . . . . . . . . . . . . . .216
54488 . . . . . . . . . . . . . . . . . . . . . . . .216
54499 . . . . . . . . . . . . . . . . . . . . . . . .217
54500 . . . . . . . . . . . . . . . . . . . . . . . .215
54506 . . . . . . . . . . . . . . . . . . . . . . . .215
54507 . . . . . . . . . . . . . . . . . . . . . . . .217
54508 . . . . . . . . . . . . . . . . . . . . . . . .216
54510 . . . . . . . . . . . . . . . . . . . . . . . .216
54512 . . . . . . . . . . . . . . . . . . . . . . . .216
54514 . . . . . . . . . . . . . . . . . . . . . . . .216
54515 . . . . . . . . . . . . . . . . . . . . . . . .216
54516 . . . . . . . . . . . . . . . . . . . . . . . .216
54518 . . . . . . . . . . . . . . . . . . . . . . . .216
54521 . . . . . . . . . . . . . . . . . . . . . . . .219
54522 . . . . . . . . . . . . . . . . . . . . . . . .217
54523 . . . . . . . . . . . . . . . . . . . . . . . .217
54532 . . . . . . . . . . . . . . . . . . . . . . . .216
54534 . . . . . . . . . . . . . . . . . . . . . . . .216
54537 . . . . . . . . . . . . . . . . . . . . . . . .219
54547 . . . . . . . . . . . . . . . . . . . . . . . .213
54548 . . . . . . . . . . . . . . . . . . . . . . . .219
54549 . . . . . . . . . . . . . . . . . . . . . . . .216
54551 . . . . . . . . . . . . . . . . . . . . . . . .216
54555 . . . . . . . . . . . . . . . . . . . . . . . .219
54559 . . . . . . . . . . . . . . . . . . . . . . . .216
54560 . . . . . . . . . . . . . . . . . . . . . . . .219
54561 . . . . . . . . . . . . . . . . . . . . . . . .211
54570 . . . . . . . . . . . . . . . . . . . . . . . .216
54571 . . . . . . . . . . . . . . . . . . . . . . . .216
54574 . . . . . . . . . . . . . . . . . . . . . . . .216
54584 . . . . . . . . . . . . . . . . . . . . . . . .219
54585 . . . . . . . . . . . . . . . . . . . . . . . .211
54588 . . . . . . . . . . . . . . . . . . . . . . . .219
54589 . . . . . . . . . . . . . . . . . . . . . . . .216
54598 . . . . . . . . . . . . . . . . . . . . . . . .216
54602 . . . . . . . . . . . . . . . . . . . . . . . .217
54603 . . . . . . . . . . . . . . . . . . . . . . . .217
54604 . . . . . . . . . . . . . . . . . . . . . . . .217
54605 . . . . . . . . . . . . . . . . . . . . . . . .217
54606 . . . . . . . . . . . . . . . . . . . . . . . .214
54607 . . . . . . . . . . . . . . . . . . . . . . . .214
54608 . . . . . . . . . . . . . . . . . . . . . . . .214
54611 . . . . . . . . . . . . . . . . . . . . . . . .217
54613 . . . . . . . . . . . . . . . . . . . . . . . .215
54614 . . . . . . . . . . . . . . . . . . . . . . . .217
54618 . . . . . . . . . . . . . . . . . . . . . . . .217
54619 . . . . . . . . . . . . . . . . . . . . . . . .217
54622 . . . . . . . . . . . . . . . . . . . . . . . .217
54623 . . . . . . . . . . . . . . . . . . . . . . . .217
54625 . . . . . . . . . . . . . . . . . . . . . . . .217
54629 . . . . . . . . . . . . . . . . . . . . . . . .216
54631 . . . . . . . . . . . . . . . . . . . . . . . .216
54633 . . . . . . . . . . . . . . . . . . . . . . . .219
54638 . . . . . . . . . . . . . . . . . . . . . . . .216
54647 . . . . . . . . . . . . . . . . . . . . . . . .215
54648 . . . . . . . . . . . . . . . . . . . . . . . .215
54649 . . . . . . . . . . . . . . . . . . . . . . . .217
54652 . . . . . . . . . . . . . . . . . . . . . . . .215
54653 . . . . . . . . . . . . . . . . . . . . . . . .217
54654 . . . . . . . . . . . . . . . . . . . . . . . .215
54655 . . . . . . . . . . . . . . . . . . . . . . . .215
54656 . . . . . . . . . . . . . . . . . . . . . . . .215
54659 . . . . . . . . . . . . . . . . . . . . . . . .215
54660 . . . . . . . . . . . . . . . . . . . . . . . .211
54662 . . . . . . . . . . . . . . . . . . . . . . . .215
54664 . . . . . . . . . . . . . . . . . . . . . . . .215
54665 . . . . . . . . . . . . . . . . . . . . . . . .217
3:25 PM
Page 284
Type
For more complete product information visit www.sylvania.com
284
Page Type
54670 . . . . . . . . . . . . . . . . . . . . . . . .217
54681 . . . . . . . . . . . . . . . . . . . . . . . .216
54685 . . . . . . . . . . . . . . . . . . . . . . . .215
54686 . . . . . . . . . . . . . . . . . . . . . . . .215
54687 . . . . . . . . . . . . . . . . . . . . . . . .215
54688 . . . . . . . . . . . . . . . . . . . . . . . .215
54689 . . . . . . . . . . . . . . . . . . . . . . . .215
54690 . . . . . . . . . . . . . . . . . . . . . . . .215
54691 . . . . . . . . . . . . . . . . . . . . . . . .215
54692 . . . . . . . . . . . . . . . . . . . . . . . .215
54694 . . . . . . . . . . . . . . . . . . . . . . . .215
54696 . . . . . . . . . . . . . . . . . . . . . . . .215
54698 . . . . . . . . . . . . . . . . . . . . . . . .211
54699 . . . . . . . . . . . . . . . . . . . . . . . .216
54701 . . . . . . . . . . . . . . . . . . . . . . . .217
54702 . . . . . . . . . . . . . . . . . . . . . . . .215
54703 . . . . . . . . . . . . . . . . . . . . . . . .217
54704 . . . . . . . . . . . . . . . . . . . . . . . .217
54706 . . . . . . . . . . . . . . . . . . . . . . . .215
54711 . . . . . . . . . . . . . . . . . . . . . . . .216
54716 . . . . . . . . . . . . . . . . . . . . . . . .215
54717 . . . . . . . . . . . . . . . . . . . . . . . .215
54723 . . . . . . . . . . . . . . . . . . . . . . . .212
54726 . . . . . . . . . . . . . . . . . . . . . . . .211
54730 . . . . . . . . . . . . . . . . . . . . . . . .211
54732 . . . . . . . . . . . . . . . . . . . . . . . .211
54734 . . . . . . . . . . . . . . . . . . . . . . . .212
54737 . . . . . . . . . . . . . . . . . . . . . . . .211
54743 . . . . . . . . . . . . . . . . . . . . . . . .212
54745 . . . . . . . . . . . . . . . . . . . . . . . .212
54747 . . . . . . . . . . . . . . . . . . . . . . . .211
54752 . . . . . . . . . . . . . . . . . . . . . . . .219
54753 . . . . . . . . . . . . . . . . . . . . . . . .211
54755 . . . . . . . . . . . . . . . . . . . . . . . .211
54770 . . . . . . . . . . . . . . . . . . . . . . . .229
54776 . . . . . . . . . . . . . . . . . . . . . . . .212
54787 . . . . . . . . . . . . . . . . . . . . . . . .215
54793 . . . . . . . . . . . . . . . . . . . . . . . .215
54796 . . . . . . . . . . . . . . . . . . . . . . . .217
54798 . . . . . . . . . . . . . . . . . . . . . . . .217
54799 . . . . . . . . . . . . . . . . . . . . . . . .217
54804 . . . . . . . . . . . . . . . . . . . . . . . .212
54807 . . . . . . . . . . . . . . . . . . . . . . . .217
54811 . . . . . . . . . . . . . . . . . . . . . . . .212
54812 . . . . . . . . . . . . . . . . . . . . . . . .211
54814 . . . . . . . . . . . . . . . . . . . . . . . .212
54815 . . . . . . . . . . . . . . . . . . . . . . . .217
54817 . . . . . . . . . . . . . . . . . . . . . . . .217
54825 . . . . . . . . . . . . . . . . . . . . . . . .217
54835 . . . . . . . . . . . . . . . . . . . . . . . .215
54836 . . . . . . . . . . . . . . . . . . . . . . . .215
54837 . . . . . . . . . . . . . . . . . . . . . . . .216
54840 . . . . . . . . . . . . . . . . . . . . . . . .212
54841 . . . . . . . . . . . . . . . . . . . . . . . .212
54842 . . . . . . . . . . . . . . . . . . . . . . . .212
54875 . . . . . . . . . . . . . . . . . . . . . . . .216
54882 . . . . . . . . . . . . . . . . . . . . . . . .218
54883 . . . . . . . . . . . . . . . . . . . . . . . .218
54897 . . . . . . . . . . . . . . . . . . . . . . . .213
54898 . . . . . . . . . . . . . . . . . . . . . . . .213
54900 . . . . . . . . . . . . . . . . . . . . . . . .216
54901 . . . . . . . . . . . . . . . . . . . . . . . .214
54904 . . . . . . . . . . . . . . . . . . . . . . . .213
54912 . . . . . . . . . . . . . . . . . . . . . . . .213
54913 . . . . . . . . . . . . . . . . . . . . . . . .212
54916 . . . . . . . . . . . . . . . . . . . . . . . .212
54924 . . . . . . . . . . . . . . . . . . . . . . . .211
54927 . . . . . . . . . . . . . . . . . . . . . . . .212
54928 . . . . . . . . . . . . . . . . . . . . . . . .212
54944 . . . . . . . . . . . . . . . . . . . . . . . .211
54957 . . . . . . . . . . . . . . . . . . . . . . . .212
54979 . . . . . . . . . . . . . . . . . . . . . . . .213
54984 . . . . . . . . . . . . . . . . . . . . . . . .212
54986 . . . . . . . . . . . . . . . . . . . . . . . .212
54988 . . . . . . . . . . . . . . . . . . . . . . . .212
55002 . . . . . . . . . . . . . . . . . . . . . . . .212
55052 . . . . . . . . . . . . . . . . . . . . . . . .217
55139 . . . . . . . . . . . . . . . . . . . . . . . .227
56000 . . . . . . . . . . . . . . . . . . . . . . . .218
56001 . . . . . . . . . . . . . . . . . . . . . . . .218
56002 . . . . . . . . . . . . . . . . . . . . . . . .218
56003 . . . . . . . . . . . . . . . . . . . . . . . .218
Page Type
56004 . . . . . . . . . . . . . . . . . . . . . . . .218
56005 . . . . . . . . . . . . . . . . . . . . . . . .218
56006 . . . . . . . . . . . . . . . . . . . . . . . .218
56007 . . . . . . . . . . . . . . . . . . . . . . . .218
56008 . . . . . . . . . . . . . . . . . . . . . . . .218
56009 . . . . . . . . . . . . . . . . . . . . . . . .218
56010 . . . . . . . . . . . . . . . . . . . . . . . .218
56011 . . . . . . . . . . . . . . . . . . . . . . . .218
56012 . . . . . . . . . . . . . . . . . . . . . . . .218
56014 . . . . . . . . . . . . . . . . . . . . . . . .218
56015 . . . . . . . . . . . . . . . . . . . . . . . .218
56016 . . . . . . . . . . . . . . . . . . . . . . . .218
56017 . . . . . . . . . . . . . . . . . . . . . . . .218
56018 . . . . . . . . . . . . . . . . . . . . . . . .218
56019 . . . . . . . . . . . . . . . . . . . . . . . .218
56086 . . . . . . . . . . . . . . . . . . . . . . . .218
56213 . . . . . . . . . . . . . . . . . . . . . . . .218
56214 . . . . . . . . . . . . . . . . . . . . . . . .218
56215 . . . . . . . . . . . . . . . . . . . . . . . .218
56216 . . . . . . . . . . . . . . . . . . . . . . . .219
56217 . . . . . . . . . . . . . . . . . . . . . . . .218
56220 . . . . . . . . . . . . . . . . . . . . . . . .221
56222 . . . . . . . . . . . . . . . . . . . . . . . .220
56223 . . . . . . . . . . . . . . . . . . . . . . . .220
56229 . . . . . . . . . . . . . . . . . . . . . . . .220
56232 . . . . . . . . . . . . . . . . . . . . . . . .218
56233 . . . . . . . . . . . . . . . . . . . . . . . .218
56234 . . . . . . . . . . . . . . . . . . . . . . . .218
56280 . . . . . . . . . . . . . . . . . . . . . . . .218
56281 . . . . . . . . . . . . . . . . . . . . . . . .218
56283 . . . . . . . . . . . . . . . . . . . . . . . .218
58493 . . . . . . . . . . . . . . . . . . . . . . . .221
58497 . . . . . . . . . . . . . . . . . . . . . . . .215
58497 . . . . . . . . . . . . . . . . . . . . . . . .217
58506 . . . . . . . . . . . . . . . . . . . . . . . .220
58510 . . . . . . . . . . . . . . . . . . . . . . . .215
58524 . . . . . . . . . . . . . . . . . . . . . . . .214
58525 . . . . . . . . . . . . . . . . . . . . . . . .217
58545 . . . . . . . . . . . . . . . . . . . . . . . .220
58639 . . . . . . . . . . . . . . . . . . . . . . . .217
58649 . . . . . . . . . . . . . . . . . . . . . . . .221
58697 . . . . . . . . . . . . . . . . . . . . . . . .220
58703 . . . . . . . . . . . . . . . . . . . . . . . .221
58704 . . . . . . . . . . . . . . . . . . . . . . . .220
58705 . . . . . . . . . . . . . . . . . . . . . . . .220
58706 . . . . . . . . . . . . . . . . . . . . . . . .221
58707 . . . . . . . . . . . . . . . . . . . . . . . .221
58708 . . . . . . . . . . . . . . . . . . . . . . . .221
58709 . . . . . . . . . . . . . . . . . . . . . . . .221
58717 . . . . . . . . . . . . . . . . . . . . . . . .221
58722 . . . . . . . . . . . . . . . . . . . . . . . .220
58724 . . . . . . . . . . . . . . . . . . . . . . . .221
58726 . . . . . . . . . . . . . . . . . . . . . . . .221
58729 . . . . . . . . . . . . . . . . . . . . . . . .213
58730 . . . . . . . . . . . . . . . . . . . . . . . .220
58758 . . . . . . . . . . . . . . . . . . . . . . . .220
58759 . . . . . . . . . . . . . . . . . . . . . . . .221
58771 . . . . . . . . . . . . . . . . . . . . . . . .212
58777 . . . . . . . . . . . . . . . . . . . . . . . .221
58782 . . . . . . . . . . . . . . . . . . . . . . . .212
58786 . . . . . . . . . . . . . . . . . . . . . . . .212
58787 . . . . . . . . . . . . . . . . . . . . . . . .220
58813 . . . . . . . . . . . . . . . . . . . . . . . .220
58815 . . . . . . . . . . . . . . . . . . . . . . . .221
58821 . . . . . . . . . . . . . . . . . . . . . . . .221
58827 . . . . . . . . . . . . . . . . . . . . . . . .215
58831 . . . . . . . . . . . . . . . . . . . . . . . .211
58846 . . . . . . . . . . . . . . . . . . . . . . . .220
58849 . . . . . . . . . . . . . . . . . . . . . . . .213
58850 . . . . . . . . . . . . . . . . . . . . . . . .220
58851 . . . . . . . . . . . . . . . . . . . . . . . .221
58854 . . . . . . . . . . . . . . . . . . . . . . . .221
58855 . . . . . . . . . . . . . . . . . . . . . . . .221
58860 . . . . . . . . . . . . . . . . . . . . . . . .216
58862 . . . . . . . . . . . . . . . . . . . . . . . .216
58877 . . . . . . . . . . . . . . . . . . . . . . . .220
58889 . . . . . . . . . . . . . . . . . . . . . . . .220
58891 . . . . . . . . . . . . . . . . . . . . . . . .220
58892 . . . . . . . . . . . . . . . . . . . . . . . .220
58893 . . . . . . . . . . . . . . . . . . . . . . . .220
58894 . . . . . . . . . . . . . . . . . . . . . . . .220
58899 . . . . . . . . . . . . . . . . . . . . . . . .220
Page Type
58905 . . . . . . . . . . . . . . . . . . . . . . . .220
58906 . . . . . . . . . . . . . . . . . . . . . . . .221
58907 . . . . . . . . . . . . . . . . . . . . . . . .220
58908 . . . . . . . . . . . . . . . . . . . . . . . .220
58930 . . . . . . . . . . . . . . . . . . . . . . . .217
58936 . . . . . . . . . . . . . . . . . . . . . . . .216
58937 . . . . . . . . . . . . . . . . . . . . . . . .215
58938 . . . . . . . . . . . . . . . . . . . . . . . .220
58939 . . . . . . . . . . . . . . . . . . . . . . . .213
58941 . . . . . . . . . . . . . . . . . . . . . . . .213
58942 . . . . . . . . . . . . . . . . . . . . . . . .216
58952 . . . . . . . . . . . . . . . . . . . . . . . .221
58953 . . . . . . . . . . . . . . . . . . . . . . . .221
58958 . . . . . . . . . . . . . . . . . . . . . . . .217
58960 . . . . . . . . . . . . . . . . . . . . . . . .221
58961 . . . . . . . . . . . . . . . . . . . . . . . .221
58963 . . . . . . . . . . . . . . . . . . . . . . . .221
58964 . . . . . . . . . . . . . . . . . . . . . . . .220
59078 . . . . . . . . . . . . . . . . . . . . . . . .221
59803 . . . . . . . . . . . . . . . . . . . . . . . .219
59822 . . . . . . . . . . . . . . . . . . . . . . . .219
59841 . . . . . . . . . . . . . . . . . . . . . . . .219
59850 . . . . . . . . . . . . . . . . . . . . . . . .219
59859 . . . . . . . . . . . . . . . . . . . . . . . .219
59860 . . . . . . . . . . . . . . . . . . . . . . . .219
59864 . . . . . . . . . . . . . . . . . . . . . . . .219
59867 . . . . . . . . . . . . . . . . . . . . . . . .219
59870 . . . . . . . . . . . . . . . . . . . . . . . .219
59928 . . . . . . . . . . . . . . . . . . . . . . . .220
59934 . . . . . . . . . . . . . . . . . . . . . . . .219
59936 . . . . . . . . . . . . . . . . . . . . . . . .219
69000 . . . . . . . . . . . . . . . . . . . . . . . .229
69119 . . . . . . . . . . . . . . . . . . . . . . . .257
69120 . . . . . . . . . . . . . . . . . . . . . . . .257
69121 . . . . . . . . . . . . . . . . . . . . . . . .264
69122 . . . . . . . . . . . . . . . . . . . . . . . .262
69125 . . . . . . . . . . . . . . . . . . . . . . . .257
69127 . . . . . . . . . . . . . . . . . . . . . . . .265
69134 . . . . . . . . . . . . . . . . . . . . . . . .258
69135 . . . . . . . . . . . . . . . . . . . . . . . .266
69136 . . . . . . . . . . . . . . . . . . . . . . . .258
69137 . . . . . . . . . . . . . . . . . . . . . . . .266
69138 . . . . . . . . . . . . . . . . . . . . . . . .267
69153 . . . . . . . . . . . . . . . . . . . . . . . .247
69154 . . . . . . . . . . . . . . . . . . . . . . . .246
69155 . . . . . . . . . . . . . . . . . . . . . . . .243
69160 . . . . . . . . . . . . . . . . . . . . . . . .245
69161 . . . . . . . . . . . . . . . . . . . . . . . .266
69162 . . . . . . . . . . . . . . . . . . . . . . . .266
69163 . . . . . . . . . . . . . . . . . . . . . . . .256
69164 . . . . . . . . . . . . . . . . . . . . . . . .267
69165 . . . . . . . . . . . . . . . . . . . . . . . .266
69166 . . . . . . . . . . . . . . . . . . . . . . . .263
69167 . . . . . . . . . . . . . . . . . . . . . . . .239
69168 . . . . . . . . . . . . . . . . . . . . . . . .258
69169 . . . . . . . . . . . . . . . . . . . . . . . .265
69171 . . . . . . . . . . . . . . . . . . . . . . . .261
69172 . . . . . . . . . . . . . . . . . . . . . . . .264
69174 . . . . . . . . . . . . . . . . . . . . . . . .265
69175 . . . . . . . . . . . . . . . . . . . . . . . .260
69176 . . . . . . . . . . . . . . . . . . . . . . . .260
69177 . . . . . . . . . . . . . . . . . . . . . . . .260
69179 . . . . . . . . . . . . . . . . . . . . . . . .261
69180 . . . . . . . . . . . . . . . . . . . . . . . .261
69181 . . . . . . . . . . . . . . . . . . . . . . . .262
69182 . . . . . . . . . . . . . . . . . . . . . . . .254
69183 . . . . . . . . . . . . . . . . . . . . . . . .239
69184 . . . . . . . . . . . . . . . . . . . . . . . .239
69186 . . . . . . . . . . . . . . . . . . . . . . . .239
69189 . . . . . . . . . . . . . . . . . . . . . . . .263
69190 . . . . . . . . . . . . . . . . . . . . . . . .238
69191 . . . . . . . . . . . . . . . . . . . . . . . .237
69195 . . . . . . . . . . . . . . . . . . . . . . . .261
69197 . . . . . . . . . . . . . . . . . . . . . . . .237
69198 . . . . . . . . . . . . . . . . . . . . . . . .255
69199 . . . . . . . . . . . . . . . . . . . . . . . .263
69200 . . . . . . . . . . . . . . . . . . . . . . . .261
69205 . . . . . . . . . . . . . . . . . . . . . . . .259
69206 . . . . . . . . . . . . . . . . . . . . . . . .259
69213 . . . . . . . . . . . . . . . . . . . . . . . .254
69214 . . . . . . . . . . . . . . . . . . . . . . . .254
69215 . . . . . . . . . . . . . . . . . . . . . . . .254
Page
69217 . . . . . . . . . . . . . . . . . . . . . . . .254
69222 . . . . . . . . . . . . . . . . . . . . . . . .255
69223 . . . . . . . . . . . . . . . . . . . . . . . .255
69224 . . . . . . . . . . . . . . . . . . . . . . . .255
69225 . . . . . . . . . . . . . . . . . . . . . . . .256
69226 . . . . . . . . . . . . . . . . . . . . . . . .259
69228 . . . . . . . . . . . . . . . . . . . . . . . .259
69231 . . . . . . . . . . . . . . . . . . . . . . . .237
69232 . . . . . . . . . . . . . . . . . . . . . . . .237
69233 . . . . . . . . . . . . . . . . . . . . . . . .237
69234 . . . . . . . . . . . . . . . . . . . . . . . .238
69235 . . . . . . . . . . . . . . . . . . . . . . . .238
69236 . . . . . . . . . . . . . . . . . . . . . . . .239
69237 . . . . . . . . . . . . . . . . . . . . . . . .238
69238 . . . . . . . . . . . . . . . . . . . . . . . .238
69241 . . . . . . . . . . . . . . . . . . . . . . . .240
69242 . . . . . . . . . . . . . . . . . . . . . . . .240
69243 . . . . . . . . . . . . . . . . . . . . . . . .240
69244 . . . . . . . . . . . . . . . . . . . . . . . .240
69245 . . . . . . . . . . . . . . . . . . . . . . . .240
69246 . . . . . . . . . . . . . . . . . . . . . . . .258
69247 . . . . . . . . . . . . . . . . . . . . . . . .244
69248 . . . . . . . . . . . . . . . . . . . . . . . .245
69249 . . . . . . . . . . . . . . . . . . . . . . . .245
69250 . . . . . . . . . . . . . . . . . . . . . . . .247
69251 . . . . . . . . . . . . . . . . . . . . . . . .246
69252 . . . . . . . . . . . . . . . . . . . . . . . .247
69254 . . . . . . . . . . . . . . . . . . . . . . . .248
69256 . . . . . . . . . . . . . . . . . . . . . . . .244
69257 . . . . . . . . . . . . . . . . . . . . . . . .241
69260 . . . . . . . . . . . . . . . . . . . . . . . .241
69261 . . . . . . . . . . . . . . . . . . . . . . . .241
69263 . . . . . . . . . . . . . . . . . . . . . . . .241
69264 . . . . . . . . . . . . . . . . . . . . . . . .241
69265 . . . . . . . . . . . . . . . . . . . . . . . .242
69266 . . . . . . . . . . . . . . . . . . . . . . . .242
69267 . . . . . . . . . . . . . . . . . . . . . . . .242
69268 . . . . . . . . . . . . . . . . . . . . . . . .242
69269 . . . . . . . . . . . . . . . . . . . . . . . .242
69270 . . . . . . . . . . . . . . . . . . . . . . . .244
69273 . . . . . . . . . . . . . . . . . . . . . . . .260
69282 . . . . . . . . . . . . . . . . . . . . . . . .269
69284 . . . . . . . . . . . . . . . . . . . . . . . .269
69287 . . . . . . . . . . . . . . . . . . . . . . . .263
69288 . . . . . . . . . . . . . . . . . . . . . . . .264
69289 . . . . . . . . . . . . . . . . . . . . . . . .264
69292 . . . . . . . . . . . . . . . . . . . . . . . .263
69294 . . . . . . . . . . . . . . . . . . . . . . . .249
69295 . . . . . . . . . . . . . . . . . . . . . . . .252
69296 . . . . . . . . . . . . . . . . . . . . . . . .248
69299 . . . . . . . . . . . . . . . . . . . . . . . .264
69303 . . . . . . . . . . . . . . . . . . . . . . . .262
69306 . . . . . . . . . . . . . . . . . . . . . . . .262
69310 . . . . . . . . . . . . . . . . . . . . . . . .244
69311 . . . . . . . . . . . . . . . . . . . . . . . .255
69315 . . . . . . . . . . . . . . . . . . . . . . . .250
69316 . . . . . . . . . . . . . . . . . . . . . . . .256
69319 . . . . . . . . . . . . . . . . . . . . . . . .262
69327 . . . . . . . . . . . . . . . . . . . . . . . .268
69336 . . . . . . . . . . . . . . . . . . . . . . . .250
69338 . . . . . . . . . . . . . . . . . . . . . . . .270
69339 . . . . . . . . . . . . . . . . . . . . . . . .251
69340 . . . . . . . . . . . . . . . . . . . . . . . .251
69343 . . . . . . . . . . . . . . . . . . . . . . . .259
69344 . . . . . . . . . . . . . . . . . . . . . . . .265
69347 . . . . . . . . . . . . . . . . . . . . . . . .260
69349 . . . . . . . . . . . . . . . . . . . . . . . .270
69350 . . . . . . . . . . . . . . . . . . . . . . . .249
69351 . . . . . . . . . . . . . . . . . . . . . . . .252
69352 . . . . . . . . . . . . . . . . . . . . . . . .270
69359 . . . . . . . . . . . . . . . . . . . . . . . .250
69360 . . . . . . . . . . . . . . . . . . . . . . . .250
69364 . . . . . . . . . . . . . . . . . . . . . . . .258
69384 . . . . . . . . . . . . . . . . . . . . . . . .243
69385 . . . . . . . . . . . . . . . . . . . . . . . .243
69386 . . . . . . . . . . . . . . . . . . . . . . . .251
69389 . . . . . . . . . . . . . . . . . . . . . . . .250
69390 . . . . . . . . . . . . . . . . . . . . . . . .247
69394 . . . . . . . . . . . . . . . . . . . . . . . .248
69456 . . . . . . . . . . . . . . . . . . . . . . . .265
69459 . . . . . . . . . . . . . . . . . . . . . . . .249
69460 . . . . . . . . . . . . . . . . . . . . . . . .251
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Index by Product Number
(continued)
Type
Page 285
Index by ANSI Code
Type
Type
Page
Page ENL . . . . . . . . . . . . . . . . . . . . . . . . .212
ENX . . . . . . . . . . . . . . . . . . . . . . . . .212
Page BAA . . . . . . . . . . . . . . . . . . . . . . . . .211 ENX-5 . . . . . . . . . . . . . . . . . . . . . . . .212
BBA . . . . . . . . . . . . . . . . . . . . . . . . .211
69461 . . . . . . . . . . . . . . . . . . . . . . . .252
69462 . . . . . . . . . . . . . . . . . . . . . . . .245
69463 . . . . . . . . . . . . . . . . . . . . . . . .249
69470 . . . . . . . . . . . . . . . . . . . . . . . .243
69474 . . . . . . . . . . . . . . . . . . . . . . . .248
69475 . . . . . . . . . . . . . . . . . . . . . . . .246
69476 . . . . . . . . . . . . . . . . . . . . . . . .251
69477 . . . . . . . . . . . . . . . . . . . . . . . .243
69478 . . . . . . . . . . . . . . . . . . . . . . . .246
69479 . . . . . . . . . . . . . . . . . . . . . . . .247
69480 . . . . . . . . . . . . . . . . . . . . . . . .245
69481 . . . . . . . . . . . . . . . . . . . . . . . .248
69482 . . . . . . . . . . . . . . . . . . . . . . . .253
69483 . . . . . . . . . . . . . . . . . . . . . . . .253
69484 . . . . . . . . . . . . . . . . . . . . . . . .253
69485 . . . . . . . . . . . . . . . . . . . . . . . .253
69486 . . . . . . . . . . . . . . . . . . . . . . . .244
69487 . . . . . . . . . . . . . . . . . . . . . . . .246
69488 . . . . . . . . . . . . . . . . . . . . . . . .249
69489 . . . . . . . . . . . . . . . . . . . . . . . .252
76302 . . . . . . . . . . . . . . . . . . . . . . . .215
76302 . . . . . . . . . . . . . . . . . . . . . . . .219
76304 . . . . . . . . . . . . . . . . . . . . . . . .214
76304 . . . . . . . . . . . . . . . . . . . . . . . .219
76305 . . . . . . . . . . . . . . . . . . . . . . . .214
76311 . . . . . . . . . . . . . . . . . . . . . . . .213
76311 . . . . . . . . . . . . . . . . . . . . . . . .219
76313 . . . . . . . . . . . . . . . . . . . . . . . .213
76313 . . . . . . . . . . . . . . . . . . . . . . . .219
76314 . . . . . . . . . . . . . . . . . . . . . . . .213
76314 . . . . . . . . . . . . . . . . . . . . . . . .219
76321 . . . . . . . . . . . . . . . . . . . . . . . .213
76321 . . . . . . . . . . . . . . . . . . . . . . . .219
BCA . . . . . . . . . . . . . . . . . . . . . . . . .215
BCM . . . . . . . . . . . . . . . . . . . . . . . . .215
BHC/DYS/DYV . . . . . . . . . . . . . . . . .215
BHC/DYS/DYV-5 . . . . . . . . . . . . . . .215
BRJ/EVB . . . . . . . . . . . . . . . . . . . . .211
BRL . . . . . . . . . . . . . . . . . . . . . . . . .211
BRN . . . . . . . . . . . . . . . . . . . . . . . . .211
BTL . . . . . . . . . . . . . . . . . . . . . . . . .215
BTM . . . . . . . . . . . . . . . . . . . . . . . . .215
BTN . . . . . . . . . . . . . . . . . . . . . . . . .215
BTP . . . . . . . . . . . . . . . . . . . . . . . . .215
BTR . . . . . . . . . . . . . . . . . . . . . . . . .215
BVE . . . . . . . . . . . . . . . . . . . . . . . . .211
BVM . . . . . . . . . . . . . . . . . . . . . . . . .215
BVT . . . . . . . . . . . . . . . . . . . . . . . . .215
BVV . . . . . . . . . . . . . . . . . . . . . . . . .215
BVW . . . . . . . . . . . . . . . . . . . . . . . . .215
CAX . . . . . . . . . . . . . . . . . . . . . . . . .211
CXZ . . . . . . . . . . . . . . . . . . . . . . . . .215
CYV . . . . . . . . . . . . . . . . . . . . . . . . .215
CYX . . . . . . . . . . . . . . . . . . . . . . . . .215
DDL . . . . . . . . . . . . . . . . . . . . . . . . .211
DDM . . . . . . . . . . . . . . . . . . . . . . . . .211
DDS . . . . . . . . . . . . . . . . . . . . . . . . .211
DED . . . . . . . . . . . . . . . . . . . . . . . . .211
DNE . . . . . . . . . . . . . . . . . . . . . . . . .211
DNF . . . . . . . . . . . . . . . . . . . . . . . . .211
DNS/FMC . . . . . . . . . . . . . . . . . . . . .215
DPY . . . . . . . . . . . . . . . . . . . . . . . . .215
DTA . . . . . . . . . . . . . . . . . . . . . . . . .215
DTY . . . . . . . . . . . . . . . . . . . . . . . . .215
DWE . . . . . . . . . . . . . . . . . . . . . . . . .215
DWT . . . . . . . . . . . . . . . . . . . . . . . . .215
DXW . . . . . . . . . . . . . . . . . . . . . . . . .215
DYH . . . . . . . . . . . . . . . . . . . . . . . . .211
DZE/FDS . . . . . . . . . . . . . . . . . . . . . .211
EBV . . . . . . . . . . . . . . . . . . . . . . . . .211
ECA . . . . . . . . . . . . . . . . . . . . . . . . .211
ECR . . . . . . . . . . . . . . . . . . . . . . . . .215
ECT . . . . . . . . . . . . . . . . . . . . . . . . .211
EFM . . . . . . . . . . . . . . . . . . . . . . . . .211
EFN . . . . . . . . . . . . . . . . . . . . . . . . .211
EFP . . . . . . . . . . . . . . . . . . . . . . . . . .211
EFP/X . . . . . . . . . . . . . . . . . . . . . . . .211
EFR . . . . . . . . . . . . . . . . . . . . . . . . .211
EFR-5/X . . . . . . . . . . . . . . . . . . . . . .211
EFX . . . . . . . . . . . . . . . . . . . . . . . . . .215
EGE . . . . . . . . . . . . . . . . . . . . . . . . .215
EGG . . . . . . . . . . . . . . . . . . . . . . . . .215
EGJ . . . . . . . . . . . . . . . . . . . . . . . . .215
EGK . . . . . . . . . . . . . . . . . . . . . . . . .215
EGN . . . . . . . . . . . . . . . . . . . . . . . . .215
EGR . . . . . . . . . . . . . . . . . . . . . . . . .215
EGT . . . . . . . . . . . . . . . . . . . . . . . . .215
EGW . . . . . . . . . . . . . . . . . . . . . . . . .215
EHA . . . . . . . . . . . . . . . . . . . . . . . . .211
EHC/EHB . . . . . . . . . . . . . . . . . . . . .215
EHD . . . . . . . . . . . . . . . . . . . . . . . . .216
EHE . . . . . . . . . . . . . . . . . . . . . . . . .211
EHF . . . . . . . . . . . . . . . . . . . . . . . . .216
EHG . . . . . . . . . . . . . . . . . . . . . . . . .216
EHJ . . . . . . . . . . . . . . . . . . . . . . . . .211
EHP . . . . . . . . . . . . . . . . . . . . . . . . .216
EHR . . . . . . . . . . . . . . . . . . . . . . . . .216
EJA . . . . . . . . . . . . . . . . . . . . . . . . . .211
EJG . . . . . . . . . . . . . . . . . . . . . . . . .216
EJL . . . . . . . . . . . . . . . . . . . . . . . . . .211
EJM . . . . . . . . . . . . . . . . . . . . . . . . .211
EJV . . . . . . . . . . . . . . . . . . . . . . . . . .211
EKB . . . . . . . . . . . . . . . . . . . . . . . . .216
EKE . . . . . . . . . . . . . . . . . . . . . . . . .212
EKE/X . . . . . . . . . . . . . . . . . . . . . . . .212
EKP/ENA . . . . . . . . . . . . . . . . . . . . .212
ELC . . . . . . . . . . . . . . . . . . . . . . . . .212
ELD . . . . . . . . . . . . . . . . . . . . . . . . .212
ELH . . . . . . . . . . . . . . . . . . . . . . . . .212
ENG . . . . . . . . . . . . . . . . . . . . . . . . .212
ENH . . . . . . . . . . . . . . . . . . . . . . . . .212
ENH-5 . . . . . . . . . . . . . . . . . . . . . . .212
For more complete product information visit www.sylvania.com
ENX-7 . . . . . . . . . . . . . . . . . . . . . . . .212
EPT . . . . . . . . . . . . . . . . . . . . . . . . .212
EPX . . . . . . . . . . . . . . . . . . . . . . . . .212
EPZ . . . . . . . . . . . . . . . . . . . . . . . . .212
ESA/FHD . . . . . . . . . . . . . . . . . . . . .212
ESB . . . . . . . . . . . . . . . . . . . . . . . . .212
ETJ . . . . . . . . . . . . . . . . . . . . . . . . . .212
EVA . . . . . . . . . . . . . . . . . . . . . . . . .212
EVC . . . . . . . . . . . . . . . . . . . . . . . . .212
EVD . . . . . . . . . . . . . . . . . . . . . . . . .212
EVW . . . . . . . . . . . . . . . . . . . . . . . . .212
EXC . . . . . . . . . . . . . . . . . . . . . . . . .218
EXD . . . . . . . . . . . . . . . . . . . . . . . . .218
EXE . . . . . . . . . . . . . . . . . . . . . . . . .218
EXR . . . . . . . . . . . . . . . . . . . . . . . . .212
EXW . . . . . . . . . . . . . . . . . . . . . . . . .212
EXY . . . . . . . . . . . . . . . . . . . . . . . . .212
EYB . . . . . . . . . . . . . . . . . . . . . . . . .213
EYB-5 . . . . . . . . . . . . . . . . . . . . . . . .213
EYB-7 . . . . . . . . . . . . . . . . . . . . . . . .213
EZE . . . . . . . . . . . . . . . . . . . . . . . . . .213
FAD . . . . . . . . . . . . . . . . . . . . . . . . .216
FAL . . . . . . . . . . . . . . . . . . . . . . . . . .216
FCB . . . . . . . . . . . . . . . . . . . . . . . . .216
FCM . . . . . . . . . . . . . . . . . . . . . . . . .216
FCR . . . . . . . . . . . . . . . . . . . . . . . . .213
FCS . . . . . . . . . . . . . . . . . . . . . . . . .213
FDA . . . . . . . . . . . . . . . . . . . . . . . . .216
FDB . . . . . . . . . . . . . . . . . . . . . . . . .216
FDG . . . . . . . . . . . . . . . . . . . . . . . . .216
FDN . . . . . . . . . . . . . . . . . . . . . . . . .216
FDS/DZE . . . . . . . . . . . . . . . . . . . . . .213
FDT . . . . . . . . . . . . . . . . . . . . . . . . .213
FDV . . . . . . . . . . . . . . . . . . . . . . . . .213
FEL . . . . . . . . . . . . . . . . . . . . . . . . . .216
FEP . . . . . . . . . . . . . . . . . . . . . . . . . .216
FER . . . . . . . . . . . . . . . . . . . . . . . . .216
FEV . . . . . . . . . . . . . . . . . . . . . . . . . .216
FEX . . . . . . . . . . . . . . . . . . . . . . . . . .216
FEY . . . . . . . . . . . . . . . . . . . . . . . . . .216
FFJ . . . . . . . . . . . . . . . . . . . . . . . . . .216
FFM . . . . . . . . . . . . . . . . . . . . . . . . .216
FFN . . . . . . . . . . . . . . . . . . . . . . . . . .218
FFP . . . . . . . . . . . . . . . . . . . . . . . . . .218
FFR . . . . . . . . . . . . . . . . . . . . . . . . . .218
FFS . . . . . . . . . . . . . . . . . . . . . . . . . .219
FFT . . . . . . . . . . . . . . . . . . . . . . . . . .216
FHM . . . . . . . . . . . . . . . . . . . . . . . . .216
FHS . . . . . . . . . . . . . . . . . . . . . . . . .213
FKJ . . . . . . . . . . . . . . . . . . . . . . . . . .216
FKK . . . . . . . . . . . . . . . . . . . . . . . . .216
FKT/EYH . . . . . . . . . . . . . . . . . . . . . .213
FKW . . . . . . . . . . . . . . . . . . . . . . . . .216
FLE . . . . . . . . . . . . . . . . . . . . . . . . . .213
FLK . . . . . . . . . . . . . . . . . . . . . . . . . .216
FLK . . . . . . . . . . . . . . . . . . . . . . . . . .216
FMR . . . . . . . . . . . . . . . . . . . . . . . . .216
FNS . . . . . . . . . . . . . . . . . . . . . . . . .213
FNT . . . . . . . . . . . . . . . . . . . . . . . . .213
FRG . . . . . . . . . . . . . . . . . . . . . . . . .216
FRK . . . . . . . . . . . . . . . . . . . . . . . . .216
FRL . . . . . . . . . . . . . . . . . . . . . . . . .216
FRN . . . . . . . . . . . . . . . . . . . . . . . . .219
FSH . . . . . . . . . . . . . . . . . . . . . . . . .216
FSX . . . . . . . . . . . . . . . . . . . . . . . . .213
FSY . . . . . . . . . . . . . . . . . . . . . . . . .213
FTK . . . . . . . . . . . . . . . . . . . . . . . . . .216
FVL . . . . . . . . . . . . . . . . . . . . . . . . . .216
FVM . . . . . . . . . . . . . . . . . . . . . . . . .216
FXL . . . . . . . . . . . . . . . . . . . . . . . . . .213
FXL-HL . . . . . . . . . . . . . . . . . . . . . . .213
GCA . . . . . . . . . . . . . . . . . . . . . . . . .216
GCB . . . . . . . . . . . . . . . . . . . . . . . . .213
GLA . . . . . . . . . . . . . . . . . . . . . . . . .216
GLC . . . . . . . . . . . . . . . . . . . . . . . . .217
GLD . . . . . . . . . . . . . . . . . . . . . . . . .217
GLE . . . . . . . . . . . . . . . . . . . . . . . . .217
GLF . . . . . . . . . . . . . . . . . . . . . . . . .217
D
I
S
P
L
A
Y
O
P
T
I
C
I
N
D
E
X
Symbols/Footnotes on page 275-281
285
071_DO_drop.qxd
12/13/07
3:25 PM
Page 286
WARNING
TUNGSTEN HALOGEN & INCANDESCENT DISPLAY/OPTIC LAMPS
The following information pertains to all Display/Optic Tungsten-Halogen and Incandescent lamps including Infrared Heat Lamps, Current-Controlled Airfield Lamps,
PAR and other Reflector Lamps.
WARNING:
In accordance with ANSI/IESNA Standard RP-27, Display/Optic incandescent & tungsten halogen lamps are Risk Group 2 products.
Read and understand this warning before using this bulb!
THIS LAMP EMITS ULTRAVIOLET AND INFRARED RADIATION. ALWAYS WEAR SUITABLE EYE PROTECTION WHEN WORKING NEAR THIS LAMP. THIS LAMP
OPERATES AT HIGH PRESSURE AND AT HIGH TEMPERATURE AND MAY SHATTER UNEXPECTEDLY. THIS LAMP MUST BE USED IN A FIXTURE THAT HAS A SUITABLE PROTECTIVE SHIELD AND/OR SCREEN TO PROTECT PEOPLE AND SURROUNDINGS AGAINST THE RISK OF PERSONAL INJURY AND/OR PROPERTY DAMAGE
FROM LAMP SHATTERING AND EXPOSURE TO INFRARED OR ULTRAVIOLET RADIATION.
ALL OF THE FOLLOWING PROCEDURES MUST BE FOLLOWED FOR SAFETY AND TO OBTAIN SATISFACTORY LAMP PERFORMANCE.
GENERAL SAFETY AND INSTALLATION TIPS:
1. This lamp generates UV (ultraviolet) and/or IR (infrared) radiation. Prolonged exposure to this lamp may cause skin and eye irritation from the radiation when
operated at or above rated voltage.
Please note that lamp with reference number 64614 has enhanced UV output as a result of its reflector coating.
2. To avoid risk of serious eye injury from the intense light, do not stare at operating lamp.
3. Because this lamp radiates considerable heat, do not use in close proximity to people, combustible materials, or substances adversely affected by heat or drying.
4. To avoid shattering of glass parts and/or lens/reflector, keep water, other liquids and metal objects from contacting hot glass surfaces. Protect the entire lamp
from moisture (rain, snow, etc.) to avoid cracking or breaking.
5. Protect the lamp from contamination, abrasion and scratches. Do not use if lamp is scratched, cracked or damaged in any way.
6. For safe and proper lamp operation, operate at rated voltage and wattage. Operation above rated voltage increases UV output and internal pressure, thus increasing the risk of rupture.
7. This lamp (for reflectorized lamps, this applies to inner lamp capsule) operates at high internal pressure and at high surface temperature and may unexpectedly
shatter resulting in hot, flying fragments of glass or metal. Although this lamp was carefully constructed, tested and inspected before packing and shipping, under
certain conditions beyond the manufacturer's control, the glass parts could crack or break.
8. For PAR and other reflectorized lamps: Even though this lamp may continue to operate after the reflector and/or lens is broken or damaged, it should be replaced
as soon as possible since the pressure-filled inner lamp capsule could unexpectedly shatter if scratched or otherwise damaged, creating a risk of personal injury
or property damage.
LAMP MOUNTING AND OPERATION:
1. Use only in equipment/fixture specifying this lamp type, including voltage and wattage. Use in circuits, which do not exceed rated voltage and in sockets and
equipment designed for its use.
2. Do not touch or handle the quartz glass with bare fingers. Contaminants can burn in at high operating temperatures and cause glass to recrystalize. This makes
the glass opaque and milky; it increasingly loses its strength, and the risk of bursting increases. If lamp is touched, clean with denatured alcohol and wipe dry
with a soft, clean lint-free cloth before operating.
3. Make sure lamp is properly installed into socket to obtain good electrical contact and to avoid damaging lamp and/or socket. A heat resistant connector should be
used to make electrical contact to the lamp base for safety and to obtain rated lamp life. To avoid damage to lamps with bipin bases, do not twist. Pull old lamp
straight out and push new lamp straight in. For safe and proper operation of lamps with lead wires, please ensure that the lamp is securely supported and the
lead-wires are securely connected to the electrical supply.
For PAR 36, 46, 56, 64 lamps: To avoid breaking, the lamp must be supported by its rim.
4. Operating temperatures deteriorate lamp sockets. Socket condition may affect lamp life. Replace socket if deterioration of socket or lamp base contacts is
observed.
5. Do not move, bump or bounce equipment/fixture during operation because mechanical shock can cause shattering and failure of the lamp.
6. For PAR 36, 46, 56 and 64 lamps: Lamp should be operated with a protective shield (especially in public places -- churches, auditoriums, etc) to prevent the risk
of personal injury or property damage from flying lamp fragments in the event of the lamp cracking or breaking.
7. To avoid risk of burns or electrical shock, do not remove or insert lamp when power is on, allow lamp to cool to room temperature before removing or storing.
8. Replace all equipment/fixture covers and shields after servicing to prevent personal injury or property damage.
9. All Display/Optic lamps have a range of permissible operating positions. Please see relevant operating position information in our literature or on-line catalog and
only operate lamps at the operating positions specified. The basic rule for all single-ended Display/Optic halogen and incandescent lamps is that the lamp may
only be tilted/inclined perpendicular to the plane through both filament lead-wires (see illustrations and list of affected filament designs below).
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
Not Permitted
Not Permitted
Permitted
Not Permitted
Affected Filament Designs:
C-2V, C-6, C-6F, C-13, C-13D, CC-2V, CC-6, CC-13, CC-13D, 2C-8, 2CC-8
10. Keep lamp seal temperature below 350°C (660°F) and the lamp wall temperature between 250°C (480°F) and 900°C (1650°F). When used in equipment designed
to provide cooling to operating lamp, do not obstruct equipment cooling system.
11. Filaments for high luminance applications are designed in such a way that the incandescent elements do not block each other in the direction of projection. The
positioning of single filament coils in one plane is called a monoplane filament. Biplane filaments have the incandescent elements staggered forward and backward in two parallel planes while maintaining adequate spacing to prevent arc-over.
12. Note: Photometric values of a frosted lamp will vary from the published values of the same non-frosted type.
For more complete product information visit www.sylvania.com
286
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 287
TUNGSTEN HALOGEN & INCANDESCENT DISPLAY/OPTIC LAMPS (continued)
LAMP DIMMING:
1. Incandescent lamps (non-halogen): Incandescent lamps perform according to fixed relationships between luminous flux, luminous efficacy, color temperature,
electrical voltage, electrical current and electrical power consumption. In general, a 5% increase in applied lamp voltage results in half the lamp life, and conversely a 5% reduction of lamp voltage results in twice the lamp life.
2. Tungsten-Halogen Lamps: In standard incandescent lamp operation, there is an inverse relationship of lamp life vs. supply voltage; i.e., the lower the voltage, the
longer the life. In some tungsten halogen lamps, however, this holds true only when operated within 5 to 10% of the rated voltage. Further dimming, beyond the
10%, may affect the halogen chemistry in the lamp and may cause filament corrosion. There are also tungsten halogen lamps that only achieve nominal lamp
lives regardless of the level of dimming that is used. Unlike standard incandescent lamps, the relationships in halogen lamps are not clear-cut because of the
halogen chemical cycle. For the vaporized tungsten to be removed from the inner bulb wall, a minimum bulb wall temperature is necessary. This temperature is
directly related to the power input to the lamp such that a reduction in power effects a reduction in the bulb wall temperature. Special design techniques have
been incorporated in modern halogen lamps to prevent blackening regardless of the level of dimming. Consideration must be given to lamp dimming in applications that require maximum constancy of color temperature (photographic and video recording, for example), since the color temperature changes with the filament temperature.
CURRENT-CONTROLLED HALOGEN LAMPS:
Some lamp types are designed for constant current operation, primarily for airfield applications. They are usually operated in series with an isolation transformer tap
connected to each lamp to ensure that all lamps have the same brightness. Constant current-operated lamps differ in performance from the published values of constant applied voltage lamps. Direct series connection of non-constant current designed lamps is not recommended.
INFRARED HEAT LAMPS:
These lamps are designed for use in applications specifically requiring an infrared radiation source. Infrared radiation from these lamps causes surfaces to be heated.
These lamps operate at high temperatures. Allow sufficient cooling time before handling. A listing of Kelvin temperatures, method for electrical connection, and operating positions with appropriate cooling recommendations for tungsten halogen special heat lamps can be found in the OSRAM literature or in the on-line catalog.
CAUTION: The infrared reflector lamp, HLX 64635 is specially designed to produce high temperatures at its focal point (approximately 1300°C / 2372°F) for soldering, welding and heating applications.
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
3. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
WARNING
®
®
®
®
®
®
®
METAL HALIDE DISPLAY/OPTIC LAMPS [HCD , HMI , HMD , HMP , HSD , HSR , HTI ]
WARNING:
In accordance with ANSI/IESNA Standard RP-27, Display/Optic metal halide lamps are a Risk Group 3 product.
Read and understand this warning before using this lamp!
THIS LAMP EMITS ULTRAVIOLET AND INFRARED RADIATION. ALWAYS WEAR SUITABLE EYE PROTECTION WHEN WORKING NEAR THIS LAMP. THIS LAMP
OPERATES AT HIGH PRESSURE AND AT HIGH TEMPERATURE AND MAY SHATTER UNEXPECTEDLY. THIS LAMP MUST BE USED IN A FIXTURE THAT HAS A SUITABLE PROTECTIVE SHIELD AND/OR SCREEN TO PROTECT PEOPLE AND SURROUNDINGS AGAINST THE RISK OF PERSONAL INJURY AND/OR PROPERTY DAMAGE
FROM LAMP SHATTERING AND EXPOSURE TO INFRARED OR ULTRAVIOLET RADIATION.
RUPTURE & RADIATION (UV-IR-VISIBLE) HAZARD:
1. All Display/Optic metal halide lamps operate at high internal pressures (upwards of 500psi or 35bar possible) and may unexpectedly rupture resulting in the discharge of hot fragments (approximately 800°C / 1472°F) of quartz and/or metal particles, as well as the release of mercury/mercury vapor. In the event of such a
rupture, there is a risk of personal injury, burns and fire.
2. All Display/Optic metal halide lamps generate ultraviolet (UV), infrared (IR) and visible radiation during operation. This radiation can cause permanent damage to
the eyes (including blindness) and serious injury to the skin (including burns and blistering). To avoid eye damage, other personal injury and/or property damage,
the lamp MUST be operated in a suitable fixture.
3. A suitable fixture is one that will prevent the arc from being viewed directly while operating, and in the event of a lamp rupture, will prevent hot (up to 800°C /
1472°F), flying fragments of quartz and/or metal from escaping into the area.
4. To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see OSRAM SYLVANIA product catalog for rated life) or when the lamp
shows signs of blackening.
5. The discharge vessel of Display/Optic metal halide lamps is constructed of quartz glass that is filled with a quantity of mercury, elemental metals and/or rare earth
elements. These lamps are not at positive pressure when cold (not operating, at room temperature).
GENERAL SAFETY & INSTALLATION TIPS
BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL):
1. In the event of a lamp rupturing during operation, all personnel should leave the area immediately to avoid the inhalation of mercury vapor. The area should then
be thoroughly ventilated for a minimum of 30 minutes or until the mercury vapor in the area is below the ACGIH TLV (American Conference of Governmental
Industrial Hygienists Threshold Limit Value). Inhaling vapor or small particles of mercury or its compounds can be harmful to lungs, kidneys and nervous system.
Penetration of the skin or ingestion can also be harmful.
2. To avoid mercury vapor getting into air conditioning systems, mercury vapor-absorbing filters should be used. When the lamp housing has cooled, mercury
residue may be picked up with special mercury adsorptive agents or a mercury vacuum cleaner (available from laboratory safety equipment suppliers) and
disposed of in accordance with local, state and federal regulations. There should be no direct skin contact with and/or inhalation of mercury residues that may
be residing in lamp housing, optics or lamp parts.
If a cold (room temperature) lamp is broken, proceed with clean up and disposal as indicated above (in the bold, italic statement).
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
287
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
071_DO_drop.qxd
12/13/07
3:25 PM
Page 288
®
®
®
®
®
®
®
METAL HALIDE DISPLAY/OPTIC LAMPS [HCD , HMI , HMD , HMP , HSD , HSR , HTI ] (continued)
INSTALLATION:
1. Do not use if lamp is scratched, cracked or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. To avoid damaging the quartz and causing premature lamp failure, do not handle lamp with bare hands. Use clean gloves.
4. If the quartz parts are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a clean, soft, lint-free cloth. Do not use cleaning rags
or material that can leave a residue.
5. To prevent skin burns, allow lamp to cool before handling.
6. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion along its
axis.
7. Display/Optic metal halide lamps should not be subjected to force/stress during installation. Single-ended lamp types use a metal bar, which runs parallel to the
lamp body and provides an electrical path for the lamp current (from the socket end to the opposite end of the lamp). To avoid overheating the lamp current bar,
Display/Optic metal halide lamp types without outer jackets should not have the lamp current bar positioned above the discharge arc during operation. Singleended lamp types with outer jackets may be operated in any position and with any current bar position.
8. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury or property damage.
9. Use only in instruments/equipment specifying this light source.
10. CAUTION - Shorting Hazard: The HTI 2500 W/SE has both base pins connected to the same point inside the lamp socket. A lead wire on the opposite side of the
lamp provides the current connection necessary for operating the lamp.
11. Make sure lamp is properly installed into socket/connector to obtain good electrical and thermal contact and avoid damaging lamp and/or socket/connector.
electrical connections should be free from dirt and corrosion. Socket/connector condition may affect lamp life. Replace socket/connector or lamp if deterioration
(pitting, scorching, corrosion, etc.) is observed.
Please note that certain Display/Optic, AC metal halide lamps have dedicated pins or connectors for high voltage ignition.
OPERATION:
1. Magnetic current-limiting ballasts (chokes) provide sine-wave current operation for lamps. However, electronic control gear (ECG) allows for square wave cur-rent
operation, often at higher frequencies. Some Display/Optic metal halide lamps have been designed for, and therefore require, ECG square-wave operation. Please
see OSRAM literature for power requirements for your specific lamp type.
2. Operate with compatible power supply and fixture only.
3. OSRAM Display/Optic metal halide discharge lamps are designed for either hot re-start (high ignition voltages) or cold start (low ignition voltages only). Please
see OSRAM literature for power requirements for your specific lamp type.
4. To ensure that lamps operate at the correct power during AC operation, connections on the ballast/choke in the power supply should be made to the correct voltage taps; i.e., tap voltage should match input line voltage. To avoid wall blackening, overheating or other premature failure modes, OSRAM strongly advises
against operating Display/Optic metal halide lamps at higher than rated wattage ("boosted operation"). Only OSRAM HMP Display/Optic metal halide lamps are
offered with a unique power feature allowing for operation at increased wattage of up to 1.5 times their rated wattage, but with reduced service life. For safe lamp
operation and optimum performance, use only those ballasts/power supplies that have been approved by OSRAM. See your OSRAM dealer for a list of approved
equipment.
5. Dimming of Display/Optic metal halide lamps, like incandescent lamps, causes a drop in luminous output. If a metal halide lamp is dimmed by electrical means, it
will not reach its optimum operating state and, unlike incandescent lamps, will not last longer. When dimmed, the lamp wall temperature falls more rapidly on a
lamp that has no outer jacket. In metal halide lamps without an outer jacket, reduced power operation causes an increase in the color temperature and a reduction in CRI. Lamps with outer jackets can have either a vacuum or filling gas (often Nitrogen) within. Metal halide lamps with outer jackets tend to maintain their
color properties better under dimmed conditions because the outer jacket provides thermal insulation against internal lamp cooling.
6. Display/Optic metal halide lamps need 5 to 20 minutes (depending on lamp type and cooling conditions) before they reach their operating temperatures. To
ensure proper ignition on subsequent start-up, lamps should not be switched off during the warm-up period.
7. Average service life of these lamps is determined by the ON/OFF duty cycle. Lamp performance is reduced with increased duty cycle.
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
OPERATING POSITION:
Display/Optic metal halide lamps may only be used in the operating positions described in the OSRAM SYLVANIA product catalog. Please note that lamp photometric values and arc stability can be effected by the operating position.
OZONE GENERATION:
• During operation, Display/Optic metal halide lamps produce a spectrum that ranges from about 150 nm in the ultraviolet region to the infrared region.
• If the quartz glass bulb is transparent in the ultraviolet region between 180 and 220 nm, this short-wave radiation will convert a small quantity of atmospheric
oxygen (O2) surrounding the lamp into ozone (O3). Moreover, the oxygen molecules will link together with the nitrogen (N2) in the air, creating nitrogen oxides
(NOx). (Some believe that the smell attributed to ozone is in actuality from the nitrogen oxides.)
• Ozone gas is toxic when inhaled in high concentrations over long periods of time. Ozone levels can be measured and monitored with commercial measuring
equipment. Always keep ozone levels below the applicable TLV (threshold limit value)
• An "ozone smell" (or smell of nitrogen oxide) may be detected shortly after ignition. There are two probable causes for this condition. O3 and NOx production is
caused by the (short-duration) radiation of the spark gap used for lamp ignition. Or, the cold condition of the quartz glass bulb has slightly shifted its UV-absorption characteristics thus permitting a small amount of radiation in the very short-wave ultraviolet range to be emitted by the bulb. Typically, after the lamp has run
up to its operating temperature range, virtually no ozone is produced by the lamp, as a rule, due to the quartz glass absorption and the self-absorption of the plasma.
LAMP COOLING:
1. All Display/Optic metal halide lamp bases must be kept below 230˚C (446˚F) during operation to prevent premature lamp failure. If convection cooling is inadequate, forced air-cooling may be used. Please see OSRAM literature for cooling requirements of specific lamp types.
2. If forced air-cooling is used, care must be taken to direct airflow at the bases only. Striking elsewhere on the lamp with the airflow will result in poor lamp performance or premature failure.
3. Discoloration, surface pitting, and/or corrosion of the lamp connections indicates a thermal overload. To obtain optimum lamp performance, components exhibiting these conditions must be cleaned or replaced.
LAMP REMOVAL:
• Turn off power to the lamp and allow lamp to cool (forced or convection) for a minimum of 30 minutes prior to shutting main fixture power and opening fixture.
Do not remove lamp until it has cooled.
• Lamps should be placed in their original OSRAM SYLVANIA packaging for temporary storage until disposal and/or transportation to a disposal location. See
"Lamp Transportation" and "Lamp Disposal" sections below for relevant information.
For more complete product information visit www.sylvania.com
288
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 289
®
®
®
®
®
®
®
METAL HALIDE DISPLAY/OPTIC LAMPS [HCD , HMI , HMD , HMP , HSD , HSR , HTI ] (continued)
LAMP TRANSPORTATION:
1. All Display/Optic metal halide lamps should be transported ONLY in their original packaging.
2. Transportation in non-original packaging can damage the lamp and void warranty.
3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLY in DOT-compliant packaging. Original OSRAM packaging is DOT-compliant.
MERCURY FILL OF Display/Optic METAL HALIDE LAMPS:
• Mercury is referred to by its chemical symbol, Hg, which is derived from the Greek and Latin "hydrargyrum," a silvery shiny liquid metal at room temperature. In
humid air it is covered with a gray oxide skin. Of all metals it has the highest vapor pressure which increases exponentially with rising temperatures. For this reason, mercury is volatile at room temperature. The colorless and odorless vapors produced are poisonous and heavier than air.
• The inhalation (respiration) of mercury or mercury compounds as vapor or dust will lead to the damage of lungs, kidneys, and the nervous system. Apart from
inhalation, mercury can be transmitted through the skin (penetration) or through the gastro-intestinal tract (ingestion), which is also harmful.
• The ACGIH TLVs are merely guidelines to assist in the control of health hazards. The ACGIH states that the TLVs refer to airborne concentrations of substances
and represent conditions under which it is believed that nearly all workers may be repeatedly exposed day after day without adverse health effects. Therefore, the
TLV for mercury should never be exceeded.
• Analytical detection of mercury vapor is possible by means of gas/vapor detector tubes (rough measurement) or air-monitors that absorb mercury vapor.
OSRAM metal halide lamps have the following mercury contents:
Lamp Family
HMI
HMP
HTI
HSR/HSD
HMD
HCD
Maximum Mercury Content (mg)
1200
70
180
110
520
23
PROPERTIES OF MERCURY:
• Chemical symbol:
• Atomic number:
• Molecular Weight:
• Density:
• Melting Point:
• Boiling Point:
• Vapor pressure:
•
Concentration in air:
•
•
•
CAS Registry Number:
RCRA waste number:
Other Names:
Hg
80
200.59
13.6 g/cm3 @ 20°C / 68°F
-39°C / -38.2°F
357°C / 674°F
160 Pa @ 20°C / 68°F
370 Pa @ 30°C / 86°F
823 Pa @ 40°C / 104°F
13.6 mg/m3 @ 20°C / 68°F
29.6 mg/m3 @ 30°C / 86°F
62.7 mg/m3 @ 40°C / 104°F
7439-97-6
U151
Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, Quecksilber, Quick silver, Liquid Silver
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. State laws may differ in their disposal requirements for lamps.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
3. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities. It
is the responsibility of the waste generator to ensure proper classification and disposal of waste products.
Hg
Lamp Contains Mercury
Manage in accordance with disposal laws
See www.lamprecycle.org or 1-866-666-6850
WARNING
VIP SUPER HIGH PRESSURE MERCURY LAMPS (DISPLAY/OPTIC)
WARNING:
In accordance with ANSI/IESNA Standard RP-27, VIP Super High Pressure Mercury Lamps are Risk Group 3 products.
Read and understand this entire statement before using this lamp!
RUPTURE & RADIATION (UV- VISIBLE) HAZARD:
1. The discharge vessel of Super High Pressure Mercury VIP lamps is constructed of quartz glass that is filled with a quantity of mercury. These lamps are not pressurized when cold (i.e., at room temperature).
2. All Super High Pressure Mercury VIP lamps have high internal pressures (up to approximately 3,675 psi or 250 bar) during operation and may unexpectedly
rupture resulting in the discharge of hot fragments (approximately 800°C / 1472°F) of quartz and/or metal particles, as well as the release of mercury/mercury vapor. In the event of such a rupture, there is a risk of personal injury, burns, and fire.
3. Super High Pressure Mercury VIP lamps generate intense ultraviolet (UV), visible and infrared radiation during operation. This radiation can cause permanent damage to the eyes (including blindness) and serious injury to the skin (including burns and blistering). To avoid eye damage, other personal injury,
and/or property damage, the lamp MUST be operated in a suitable fixture.
4. A suitable fixture is one that will prevent the arc from being viewed directly while operating, and in the event of a lamp rupture, will prevent hot (up to 800°C /
1472°F), flying fragments of quartz and/or metal from escaping into the area.
5. To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see OSRAM SYLVANIA product catalog for rated life).
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
289
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
071_DO_drop.qxd
12/13/07
3:25 PM
Page 290
VIP SUPER HIGH PRESSURE MERCURY LAMPS (DISPLAY/OPTIC) (continued)
BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL):
1. In the event of a lamp rupturing during operation, all personnel should leave the area immediately to avoid the inhalation of mercury vapor. The area should then
be thoroughly ventilated for a minimum of 30 minutes or until the mercury vapor in the area is below the ACGIH TLV (American Conference of Governmental
Industrial Hygienists Threshold Limit Value). Inhaling vapor or small particles of mercury or its compounds can be harmful to lungs, kidneys, and nervous system.
Penetration of the skin or ingestion can also be harmful.
2. When the lamp housing has cooled, mercury residue may be picked up with special mercury adsorptive agents or a mercury vacuum cleaner (available from laboratory safety equipment suppliers) and disposed of in accordance with local, state, and federal regulations. There should be no direct skin contact with and/or
inhalation of mercury residues that may be residing in lamp housing, optics or lamp parts.
3. If a cold (room temperature) lamp is broken, proceed with clean-up and disposal as indicated in item 2 above.
GENERAL SAFETY & INSTALLATION TIPS
INSTALLATION:
1. Do not use if lamp or any lamp parts such as reflector, front glass, etc. are scratched, cracked, or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. If the quartz parts are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a soft, clean, lint-free cloth. Do not use cleaning rags
or material that can leave a residue.
4. To prevent skin burns, allow lamp to cool before handling.
5. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion.
6. Super High Pressure Mercury VIP lamps should not be subjected to force/stress during installation.
7. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury, or property damage.
8. Use only in instruments/equipment specifying this light source.
9. Make sure lamp is properly connected to avoid damaging lamp and/or socket/connector. Electrical connections should be free from dirt and corrosion.
Socket/connector condition may affect lamp life.
10. Replace socket/connector or lamp if deterioration (pitting, scorching, corrosion, etc.) of either is observed.
OPERATION:
1. Super High Pressure Mercury VIP lamps are designed for operation on AC only.
2. Operate with compatible power supply and fixture only.
3. Super High Pressure Mercury VIP lamps need approximately 5 minutes (depending on lamp type and cooling conditions) before they reach their operating temperatures. To ensure proper ignition on the following start-up, lamps should not be switched off during the warm-up period.
4. The average service life of Super High Pressure Mercury VIP lamps is influenced by their ON/OFF-duty cycle. Lamp performance is reduced with increased duty
cycle.
OPERATING POSITION:
Super High Pressure Mercury VIP lamps may only be operated in the positions described in the OSRAM SYLVANIA product catalog and/or technical literature.
LAMP COOLING:
1. To prevent premature failure, forced-air cooling is required. Maximum permitted lamp temperatures are described in the available technical literature.
2. Discoloration, surface pitting, and/or corrosion of the lamp connections indicate a thermal overload. Components exhibiting these conditions must be cleaned or
replaced.
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
LAMP REMOVAL:
Turn off power to the lamp and allow lamp to cool (forced) for a minimum of 15 minutes prior to shutting main fixture power and opening fixture. Do not remove
lamp until it has cooled.
LAMP TRANSPORTATION:
1. All Super High Pressure Mercury VIP lamps should be transported ONLY in their original packaging.
2. Transportation in non-original packaging can result in damage to the lamp thus voiding the warranty.
3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLY in DOT-compliant packaging. Original OSRAM packaging is DOT-compliant.
MERCURY FILL OF SUPER HIGH PRESSURE MERCURY VIP LAMPS:
Mercury is referred to by its chemical symbol, Hg, which is derived from the Greek and Latin "hydrargyrum," a silvery, shiny liquid metal at room temperature. In
humid air it is covered with a gray oxide skin. Of all metals it has the highest vapor pressure which increases exponentially with rising temperatures. For this reason, mercury is volatile at room temperature. The colorless and odorless vapors produced are poisonous and heavier than air.
The inhalation (respiration) of mercury or mercury compounds as vapor or dust may lead to the damage of lungs, kidneys, and the nervous system. Apart from
inhalation, mercury can be transmitted through the skin (penetration) or through the gastro-intestinal tract (ingestion), which is also harmful.
Threshold Limit Values (TLVs) are not fine lines between safe and dangerous concentrations but are guidelines to assist in the control of health hazards. They
represent the maximum exposure to substances, both short-term and long-term, that a person may experience without resulting in health-related problems.
Therefore, the TLV for mercury should never be exceeded.
Analytical detection of mercury vapor is possible by means of gas/vapor detector tubes (rough measurement) or air-monitors that absorb mercury vapor.
OSRAM Super High Pressure Mercury VIP lamps have the following mercury contents:
Power level
100-200W
Maximum Mercury content (mg)
12
PROPERTIES OF MERCURY:
• Chemical symbol:
• Atomic number:
• Molecular Weight:
• Density:
• Melting Point:
• Boiling Point:
• Vapor pressure:
Hg
80
200.59
13.6 g/cm3 @ 20°C / 68°F
-39°C / -38.2°F
357°C / 674°F
160 Pa @ 20°C / 68°F
370 Pa @ 30°C / 86°F
823 Pa @ 40°C / 104°F
For more complete product information visit www.sylvania.com
290
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 291
®
VIP SUPER HIGH PRESSURE MERCURY LAMPS (DISPLAY/OPTIC) (continued)
• Concentration in air:
13.6 mg/m3 @ 20°C / 68°F
29.6 mg/m3 @ 30°C / 86°F
62.7 mg/m3 @ 40°C / 104°F
• CAS Registry Number: 7439-97-6
• RCRA waste number: U151
• Other Names:
Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, Quecksilber, Quick silver, Liquid Silver
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. Some U.S. states differ in their disposal requirements for lamps containing mercury.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
3. OSRAM SYLVANIA INC. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
Hg
Lamp Contains Mercury
Manage in accordance with disposal laws
See www.lamprecycle.org or 1-866-666-6850
WARNING
XBO® HIGH PRESSURE XENON LAMPS
WARNING:
In accordance with ANSI/IESNA Standard RP-27, this XBO bulb is a Risk Group 3 product.
Read and understand this warning before using this bulb!
XBO lamps are at high internal pressure when cold (up to 35 bar or approximately 525 psi) and at operating temperature (up to 80 bar or approximately 1200 psi
at bulb wall temperatures of 600°C to 800°C). Therefore, XBO lamps may unexpectedly rupture resulting in the discharge of hot fragments of quartz and/or
glass and metal. In the event of such a rupture, there is a risk of personal injury, burns and fire. Only handle lamps with their protective covers in place. Do
not handle lamps without their protective covers unless government-approved (OSHA-approved in the U.S.A.) safety glasses, facemask (with neck protector),
chest protector, and gauntlets are worn.
RUPTURE & RADIATION (UV-VISIBLE-IR) HAZARDS:
1. Intense ultraviolet (UV), visible, and infrared (IR) radiation is also generated during operation. This radiation can cause permanent damage to the eyes (including
blindness) and serious injury to the skin (including burns and blistering). Some operating lamps also generate ozone (O3). Others, designated "OFR," are constructed of materials that prevent the generation of ozone. See the "Ozone Generation" section below.
2. To avoid eye damage, other personal injury and/or property damage, the lamp MUST be operated in a suitable fixture. A suitable fixture is one that will prevent the
arc from being viewed directly while operating. It is ventilated to the outside for those lamps that produce ozone and, in the event of a rupture, will prevent hot
(up to 800°C), flying fragments of quartz and/or glass or metal from escaping into the surrounding area.
3. To minimize the risk of a lamp rupture, the lamp must be replaced at or before the end of rated life (see catalog for rated life) or when the lamp shows signs of
advanced blackening or quartz devitrification (recrystalization, a white, frosted appearance).
4. XBO lamps are constructed of quartz glass, tungsten electrodes and either tungsten support rods or molybdenum foils. High wattage XBO lamps used for cinema
film projection have nickel-plated end caps (bases). Reflectorized XBO lamps have a dichroic-coated borosilicate glass reflector.
GENERAL SAFETY & INSTALLATION TIPS
INSTALLATION:
1. Do not use if lamp is scratched, cracked, or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. To avoid damaging the quartz and causing premature lamp failure, do not handle lamp with bare hands.
4. Handle lamp ONLY with suitable, clean, safety gloves. See special handling instructions for using government-approved personal protective safety equipment with
high-pressure lamps.
5. If the quartz parts (or the reflector for reflectorized lamps) are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a soft, clean,
lint-free cloth. Do not use cleaning rags or material that can leave a residue.
6. To prevent skin burns, allow lamp to cool before handling.
7. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion along its
axis. For this reason, XBO lamps should be fixed at one end only and the electrical connection on the other end must be flexible enough to avoid stressing the
lamp.
8. XBO lamps should not be subjected to force/stress during installation.
9. Handle lamp only with protective safety cover in place. When installing lamp, remove safety cover only AFTER fully securing lamp in lamphouse/fixture and
immediately preceding the replacement of equipment covers or closing of lamphouse door.
10. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury, and/or property damage.
11. Use only in instruments/equipment specifying this lamp type.
12. Make sure lamp is properly installed into socket/connector to obtain good electrical and thermal contact and avoid damaging lamp and/or socket/connector.
Electrical connections should be free from dirt and corrosion.
13. Socket/connector condition may affect lamp life. Replace socket/connector or lamp if deterioration (pitting, scorching, corrosion, etc.) of either is observed.
14. All XBO lamps are designed for DC operation. Make sure that the polarity is correct before turning power on. Incorrect polarity can destroy the lamp in a matter
of seconds. Operate with compatible power supply and fixture only.
15. For best performance, operate this XBO lamp at rated current. Note: some low wattage XBO lamps may not be operated above their specified rated wattage. See
catalog for details.
16. For those XBO lamps that have a current control range, the current may be increased to its maximum value to compensate for loss of light over the life of the
lamp. Operating the lamp at minimum current does not prolong the life of the lamp. The DC current may only be varied within specified control limits for the
selected type. (See catalog for these limits for your specific lamp type.)
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
291
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
071_DO_drop.qxd
12/13/07
3:25 PM
Page 292
XBO® HIGH PRESSURE XENON LAMPS (continued)
17. When installing bare lamps that have an included flat washer, slip the washer over the threaded pin on the cathode (- negative) side. Removal of this flat washer
(after half the average life) will allow a rotation of the lamp by 180° resulting in better output maintenance over life for horizontally operated lamps. This should
be done only if darkening is evident in the upper part of the bulb. In instances where bare lamp cathode bases are provided with two metal pins, they may be
engaged with the two slots on the protective cover to screw the cathode end of the lamp into its socket.
LAMP REMOVAL:
1. Turn off power to the lamp and allow it to cool (forced or convection) for a minimum of 15 minutes prior to shutting main fixture power and opening fixture.
Do not remove lamp until it has cooled. After the lamp has cooled, place the protective cover around it and reverse the procedure described above. See special
handling instructions for using government-approved safety equipment with high-pressure lamps.
2. Lamp should be placed in the original OSRAM SYLVANIA packaging for temporary storage until disposal and/or transportation to a disposal location. See
"Lamp Disposal" section below for transportation and spent lamp disposal information.
OPERATING POSITION:
1. XBO bare lamps are designed to operate vertically. Of those, some (having an "H" in their designation) may also be operated in the horizontal position as well. For
vertically operated lamps, the anode (+ positive) electrode must be on the top. See catalog for operating position and permissible deviation for your specific type.
2. Some horizontally operated lamps require magnetic arc stabilization. Check the catalog for your specific lamp type.
3. XBO reflector lamps are designed to operate with lamp/reflector axis within 15° of the horizontal position.
LAMP COOLING:
1. Discoloration, surface pitting, and/or corrosion of the lamp indicates a thermal overload. Components exhibiting these conditions must be cleaned or replaced.
2. If forced-air cooling is used, care must be taken to direct airflow at the lamp bases only. Striking the lamp elsewhere with the airflow will result in poor lamp performance or premature failure.
3. To prevent premature failure, the following cooling instructions must be followed:
Bare lamps - Bases must be kept below 230˚C (445˚F) during operation. If convection cooling is insufficient and additional cooling is required, forced air-cooling
may be used. If forced air is used, care must be taken to direct airflow at bases only, since striking elsewhere on the lamp with the airflow will result in poor lamp
performance or premature failure. See catalog for your specific lamp type to learn whether forced air-cooling is required.
Reflector lamps - To avoid damaging the reflector coating, do not allow the outer reflector surface to exceed the maximum temperature of 250°C (480˚F).
[Optimum temperature: 175-200°C (345-390˚F)] To prevent premature failure, the lamp ends must not exceed the maximum temperature of 350°C (660˚F).
[Optimum temperature: 200-250°C (385-480˚F)] Forced air-cooling is therefore required and the air flow must be directed perpendicular to the lamp/reflector
axis, through the slots in the openings of both ceramics. See catalog for diagram.
OZONE GENERATION:
An electrical discharge in xenon gas generates radiant energy ranging from approximately 140 nm in the UV region to far into the infrared region. Xenon lamps
are made of quartz glass. The quartz glass allows for the transmission of short UV wavelengths starting from approximately 140 nm, depending on the quartz
type. Ozone gas (O3) is generated by the conversion of oxygen (O2) in the air by UV energy in the range of approximately 110-200 nm. Ozone is extremely toxic
and will cause serious health problems if inhaled in excess of allowable limits over a prolonged period of time. For more information on allowable limits, please
refer to the ACGIH (American Conference of Governmental Industrial Hygienists) publication, "TLVs and BEIs" (Threshold Limit Values and Biological Exposure
Indices). Ozone production can be suppressed in xenon discharge lamps by adding materials to the quartz glass that block short-wave UV transmission.
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
QUARTZ GLASS DESIGN OPTIONS:
OSRAM XBO® xenon lamps are offered in three quartz glass designs. They are:
1. OSRAM XBO W/4: These lamps are fabricated from synthetic Suprasil quartz glass. Suprasil quartz is low in impurities and provides for maximum short-wave
UV transmission and consequently allows for the production of ozone. These lamps should always be used with external ventilation with no possible direct exposure to humans. Under no circumstances may the applicable maximum allowable workplace concentration of ozone be exceeded for any OSRAM xenon XBO
lamps.
2. OSRAM XBO: These lamps use standard quartz glass and will also emit UV radiation that produces ozone. These lamps, like the W/4 types, must always be
externally ventilated. With these types of lamps, health risks must always be minimized by suitably extracting the air from the lamp housing and externally venting it.
3. OSRAM XBO OFR: These lamps are designated "Ozone-Free" and are characterized by the letters "OFR" in the order description. OSRAM XBO OFR type lamps
have their quartz glass transparently coated to effectively suppress radiation below approximately 250 nm, resulting in the elimination of ozone production during
operation.
LAMP DISPOSAL:
1. There is a risk that a lamp could rupture because of its high internal pressure (both hot and at room temperature). A lamp rupture could result in personal injury
or property damage from flying fragments of glass and/or metal. Therefore, spent (end-of-life) lamps should ALWAYS be stored in the protective covers and
packaging in which they originally came, and ultimately depressurized before release for disposal. The following is one example of a depressurizing method for
XBO lamps prior to disposal, but it may not be the most suitable or appropriate method depending on the circumstance:
• The operator must wear government-approved (OSHA-approved in the U.S.A.) safety glasses, facemask (with neck protector), chest protector, and
gauntlets during this entire procedure.
• With protective lamp covers in place, place lamps1 into steel drum2 and lock down cover with bolt ring and bolt.
• Drop drum onto solid surface (concrete floor) from at least five feet. Increase height as needed to ensure all lamps are depressurized.
• Wait for dust to settle (about 5 minutes) before opening drum. Loosen bolt and allow gas to escape before complete removal of cover.
1
The lamps should not exceed the half-full point in the drums. Adjust the maximum number of lamps accordingly.
8, 20, or 30-gallon drums, depending on quantity of lamps to be de-pressurized, are available. Drums of 20-gauge steel are recommended and are available from many
safety supply companies.
2
2. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. State laws differ in their disposal requirements.
3. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
4. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
For more complete product information visit www.sylvania.com
292
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 293
WARNING
HBO® HIGH PRESSURE MERCURY LAMPS
WARNING:
In accordance with ANSI/IESNA Standard RP-27, this HBO bulb is a Risk Group 3 product.
Read and understand this warning before using this bulb!
RUPTURE & RADIATION (UV- VISIBLE) HAZARD:
1. The discharge vessel of HBO lamps is constructed of quartz glass that is filled with a quantity of mercury and either Argon or Xenon gas. Most HBO lamps are
not at positive pressure when cold (not operating, at room temperature). However, there are several HBO lamps that DO have a positive internal pressure of upto
approximately 8 bar (or approximately 120 psi) in the cold (room temperature) state. The printing of the following bold warning statement on individual packages
identifies them as positive-pressure lamps.
WARNING
RISK OF LAMP RUPTURING. TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, ALWAYS WEAR PROTECTIVE CLOTHING WHEN HANDLING THESE
LAMPS. Never handle these lamps unless government-approved (OSHA-approved in the U.S.A.) safety glasses, facemask (with neck protector), chest
protector, and gauntlets are worn.
2.
3.
4.
5.
6.
These positive-pressure lamps may unexpectedly rupture resulting in the discharge of quartz and/or metal fragments as well as exposing the surrounding area to
mercury. In the event of such a rupture, there is a risk of personal injury or property damage. Therefore these positive-pressure lamps should be handled in
accordance with these safety instructions.
All HBO lamps have high internal pressures (400 - 1100 psi or 30 to 75 bar) during operation and may unexpectedly rupture resulting in the discharge of hot fragments (approximately 800°C / 1472°F) of quartz and/or metal particles, as well as the release of mercury/mercury vapor. In the event of such a rupture, there is a
risk of personal injury, burns, and fire.
All HBO lamps generate intense ultraviolet (UV) and visible radiation during operation. This radiation can cause permanent damage to the eyes (including blindness) and serious injury to the skin (including burns and blistering). To avoid eye damage, other personal injury, and/or property damage, the lamp MUST be
operated in a suitable fixture.
A suitable fixture is one that will prevent the arc from being viewed directly while operating, and in the event of a lamp rupture, will prevent hot (up to 800°C /
1472°F), flying fragments of quartz and/or metal from escaping into the area.
Fixtures for lamps that produce ozone during operation should be ventilated and filtered to the outside for ozone removal.
To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see OSRAM SYLVANIA product catalog for rated life) or when the lamp
shows signs of blackening.
BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL):
1. In the event of a lamp rupturing during operation, all personnel should leave the area immediately to avoid the inhalation of mercury vapor. The area should then
be thoroughly ventilated for a minimum of 30 minutes or until the mercury vapor in the area is below the ACGIH TLV (American Conference of Governmental
Industrial Hygienists Threshold Limit Value). Inhaling vapor or small particles of mercury or its compounds can be harmful to lungs, kidneys, and nervous system.
Penetration of the skin or ingestion can also be harmful.
2. To avoid mercury vapor getting into air conditioning systems, instruments/equipment using lamps of 350 watts or greater should be connected to separate air
exhaust systems through mercury vapor-absorbing filters. When the lamp housing has cooled, mercury residue may be picked up with special mercury adsorptive agents or a mercury vacuum cleaner (available from laboratory safety equipment suppliers) and disposed of in accordance with local, state, and federal
regulations. There should be no direct skin contact with and/or inhalation of mercury residues that may be residing in lamp housing, optics or lamp parts.
If a cold (room temperature) lamp is broken, proceed with clean-up and disposal as indicated above (in the bold, italicized statement).
GENERAL SAFETY & INSTALLATION TIPS
INSTALLATION:
1. Do not use if lamp is scratched, cracked, or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. To avoid damaging the quartz and causing premature lamp failure, do not handle lamp with bare hands.
4. Only handle lamp with suitable, clean safety gloves. See special, bolded warning for using government-approved safety equipment when handling positive-pressure lamps.
5. If the quartz parts are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a soft, clean, lint-free cloth. Do not use cleaning rags
or material that can leave a residue.
6. To prevent skin burns, allow lamp to cool before handling.
7. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion along its
axis. For this reason, HBO lamps should be fixed at one end only and the electrical connection on the other end must be flexible enough to avoid stressing the
lamp.
8. HBO lamps should not be subjected to force/stress during installation.
9. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury, or property damage.
10. Use only in instruments/equipment specifying this light source.
11. Make sure lamp is properly installed into socket/connector to obtain good electrical and thermal contact and avoid damaging lamp and/or socket/connector.
Electrical connections should be free from dirt and corrosion.
12. Socket/connector condition may affect lamp life. Replace socket/connector or lamp if deterioration (pitting, scorching, corrosion, etc.) of either is observed.
OPERATION:
1. Some HBO lamps are designed for operation on only AC or only DC while some are designed for operation on either AC or DC.
2. Note: all HBO lamps with power consumption of 350 W and higher are only suited for DC operation. Make sure that the polarity is correct before turning power
on. Incorrect polarity can destroy the lamp in a matter of seconds.
3. Operate with compatible power supply and fixture only.
4. To ensure that AC-suited lamps operate at correct power during AC operation, connections on the ballast/choke in the power supply should be made to the voltage
taps that are marked the same as the marking on the lamp base (L1 or L2). Some power supplies are equipped with a switch (or taps) for selecting L1 or L2. For
correct and safe lamp operation, use only those ballasts/power supplies that have been approved or meet minimum requirements as specified by OSRAM. See
your OSRAM dealer for list of approved equipment.
5. HBO lamps need 5 to 20 minutes (depending on lamp type and cooling conditions) before they reach their operating temperatures. To ensure proper ignition on
subsequent start-up, lamps should not be switched off during the warm-up period.
6. The average service life of high wattage HBO lamps (≥350 watts) is determined by their ON/OFF duty cycle. These lamps have been designed for a limited amount
of ignitions only (less than 10). Lamp performance is reduced with increased duty cycle.
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
293
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
071_DO_drop.qxd
12/13/07
3:25 PM
Page 294
HBO® HIGH PRESSURE MERCURY LAMPS (continued)
OPERATING POSITION:
HBO lamps may only be operated in the operating positions described in the OSRAM SYLVANIA product catalog.
Some HBO lamps are designed to operate horizontally (mainly low wattage types in the power range of 50 to 200 W) and others, vertically (all lamp types withpower consumption of 350 W and higher). Greater arc stability is obtained in vertically operating lamps when they are operated as close to vertical as possible.
See catalog for permissible operating positions and electrode positions.
OZONE GENERATION:
During operation, HBO lamps produce a spectrum that ranges from about 150 nm in the ultraviolet region to the infrared region.
If the quartz glass bulb is transparent in the ultraviolet region between 180 and 220 nm, this short-wave radiation will convert a small quantity of atmospheric
oxygen (O2) surrounding the lamp into ozone (O3). Moreover, the oxygen molecules will link together with the nitrogen (N2) in the air, creating nitrogen oxides
(NOx). (Some believe that the smell attributed to ozone is in actuality from the nitrogen oxides.)
Ozone gas is toxic when inhaled in high concentrations over long periods of time. Ozone levels can be measured and monitored with commercial measuring
equipment. Always keep ozone levels below the applicable TLV (threshold limit value).
The production of ozone and nitrogen oxide can be suppressed by using doped quartz glass, which absorbs the ozone-producing ultraviolet radiation. The quartz
glass used in high wattage i-line (365nm) enhanced HBO lamps only transmits wavelengths above 250 nm, which provides effective, ozone-free lamps. Please be
advised that the OSRAM HBO 4000 W/PL lamp is designed to generate UV wavelengths below 250nm. Consequently, this lamp will generate ozone in operation
and should be externally ventilated.
An "ozone smell" (or smell of nitrogen oxide) may be detected shortly after ignition. There are two probable causes for this condition. O3 and NOx production is
caused by the (short-duration) radiation of the spark gap used for lamp ignition. Or, the cold condition of the quartz glass bulb has slightly shifted its UV-absorption characteristics thus permitting a small amount of radiation in the very short-wave ultraviolet range to be emitted by the bulb. Typically, after the lamp has run
up to its operating temperature range, virtually no ozone is produced by the lamp, as a rule, due to the quartz glass absorption and the self-absorption of the plasma.
LAMP COOLING:
1. To prevent premature failure, lamp base temperatures must be kept below 230˚C (446˚F) for 50 to 350 watt lamps and below 200˚C (392˚F) for all lamps with
power consumption of more than 350 watts.
2. Discoloration, surface pitting, and/or corrosion of the lamp connections indicates a thermal overload. Components exhibiting these conditions must be cleaned or
replaced.
3. If convection cooling is insufficient and additional cooling is required, cooling fins may be applied to the bases and/or forced air may be used.
4. If forced air is used, care must be taken to direct airflow at the bases only. Striking elsewhere on the lamp with the airflow will result in poor lamp performance or
premature failure.
LAMP REMOVAL:
Turn off power to the lamp and allow lamp to cool (forced or convection) for a minimum of 30 minutes prior to shutting main fixture power and opening fixture.
Do not remove lamp until it has cooled. See special, bolded warning for using government-approved safety equipment when handling positive-pressure lamps.
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
Lamps should be placed in their original OSRAM SYLVANIA packaging for temporary storage until disposal and/or transportation to a disposal location. See
"Lamp Transportation" and "Lamp Disposal" sections below for relevant information.
LAMP TRANSPORTATION:
1. All HBO lamps should be transported ONLY in their original packaging.
2. Transportation in non-original packaging can damage the lamp and void warranty.
3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLY in DOT-compliant packaging. Original OSRAM packaging is DOT-compliant.
4. When transporting positive-pressure lamps, the bolded warning found in the "Rupture & Radiation Hazard" section MUST be placed on outside surface of the shipping carton and the warning instructions must also be placed inside the shipping packaging.
MERCURY FILL OF HBO LAMPS:
Mercury is referred to by its chemical symbol, Hg, which is derived from the Greek and Latin "hydrargyrum," a silvery shiny liquid metal at room temperature. In
humid air it is covered with a gray oxide skin. Of all metals it has the highest vapor pressure which increases exponentially with rising temperatures. For this reason, mercury is volatile at room temperature. The colorless and odorless vapors produced are poisonous and heavier than air.
The inhalation (respiration) of mercury or mercury compounds as vapor or dust will lead to the damage of lungs, kidneys, and the nervous system. Apart from
inhalation, mercury can be transmitted through the skin (penetration) or through the gastro-intestinal tract (ingestion), which is also harmful.
The ACGIH threshold limit values (TLVs) are merely guidelines to assist in the control of health hazards. The ACGIH says that the TLVs refer to airborne concentrations of substances and represent conditions under which it is believed that nearly all workers may be repeatedly exposed day after day without adverse health
effects. Therefore, the TLV for mercury should never be exceeded.
Analytical detection of mercury vapor is possible by means of gas/vapor detector tubes (rough measurement) or air-monitors that absorb mercury vapor.
OSRAM HBO® lamps have the following mercury contents:
Power level
Maximum Mercury content (mg)
50 - 200 W
110
350 W
300
500 W
500
1,000 W
1,000
1,500 W
800
2,000 - 2,500 W
5,000
3,500 W and higher
12,000
For more complete product information visit www.sylvania.com
294
Symbols/Footnotes on page 275-281
071_DO_drop.qxd
12/13/07
3:25 PM
Page 295
HBO® HIGH PRESSURE MERCURY LAMPS (continued)
PROPERTIES OF MERCURY:
• Chemical symbol:
• Atomic number:
• Molecular Weight:
• Density:
• Melting Point:
• Boiling Point:
• Vapor pressure:
•
Concentration in air:
•
•
•
CAS Registry Number:
RCRA waste number:
Other Names:
Hg
80
200.59
13.6 g/cm3 @ 20°C / 68°F
-39°C / -38.2°F
357°C / 674°F
160 Pa @ 20°C / 68°F
370 Pa @ 30°C / 86°F
823 Pa @ 40°C / 104°F
13.6 mg/m3 @ 20°C / 68°F
29.6 mg/m3 @ 30°C / 86°F
62.7 mg/m3 @ 40°C / 104°F
7439-97-6
U151
Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, Quecksilber, Quick silver, Liquid Silver
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. State laws differ in their disposal requirements for
lamps containing mercury.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
Hg
Lamp Contains Mercury
Manage in accordance with disposal laws
See www.lamprecycle.org or 1-866-666-6850
3. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
Special disposal note for cold, positive-pressure lamps (see "RUPTURE & RADIATION HAZARD" section for applicable lamps)
There is a risk that these lamps could rupture because of their high internal pressure when hot (during operation) and when cold (at room temperature when not
operating). A lamp rupture could result in personal injury or property damage from flying fragments of quartz and/or metal. Therefore, spent (end-of-life) lamps
should ALWAYS be stored in the packaging in which they originally came.
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
Lamp Disposal Labeling
The following information appears on the packages and/or stuffer of mercury-containing Display/Optic lamps. For more information
on lamp disposal labeling, see the inside back cover of this catalog.
Hg
Lamp Contains Mercury
Manage in accordance with disposal laws
See www.lamprecycle.org or 1-866-666-6850
For more complete product information visit www.sylvania.com
Symbols/Footnotes on page 275-281
295
071_DO_drop.qxd
12/13/07
3:25 PM
Page 296
NOTES:
D
I
S
P
L
A
Y
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com
296
Symbols/Footnotes on page 275-281
080_LED.qxd
12/12/07
4:04 PM
Page 297
LED SYSTEMS
The most important trend in lighting technology is the move towards systems… we started this trend with
THE SYSTEM SOLUTION®, a family of optimally balanced energy saving lamps and ballast combinations.
We are now extending that trend with LED systems for the lighting market.
LED systems are quickly becoming the light source of choice for signage applications due to their
ruggedness, reliability, long life, energy efficiency and low maintenance requirements. They have also
opened new avenues in lighting with their color mixing and color sequencing capabilities. They offer
unique capabilities for architectural enhancements and decorative lighting due to their small sizes
and system flexibility.
LED ADVANTAGES
OSRAM SYLVANIA has the competitive advantage in the arena of LED systems with years of
experience in designing and developing discrete LEDs, LED modules and OPTOTRONIC® electronic
LED power supplies and controls. Our global network of design and manufacturing brings LED,
electronics, and lighting systems knowledge together to produce innovative, efficient,
environmentally friendly and energy saving systems. Our LED systems are also covered by our
comprehensive LED system warranty.
High color efficiency
Low energy consumption
Long service life
Directional distribution of light
Small size
Flexible lighting solutions
No IR/UV radiation
Innovative system solutions
Consult Ballast section, page 185 for listings of OPTOTRONIC LED power supplies and controls.
Hi-flux (HF) systems
Hi Flux LED modules are the latest generation of power LEDs. They offer
exciting possibilities for LEDs in general illumination applications including
signage, cove lighting, spot and flood lighting, display lighting, freezer and
refrigeration lighting.
BACKlight Systems
Designed especially for signage applications the BACKlight System offers a
versatile alternative to neon for channel letter signs. It comes in various colors
and due to its high flexibility is also suitable for any application requiring
LEDs oriented in a 3-dimensional setting. This product is conformally coated
and is listed in the UL Sign Accessories Manual (SAM).
LINEARlight Colormix Systems
LINEARlight Colormix Flexible and Rigid modules along with OPTOTRONIC®
RGB Control system offer simple dynamic control for creating colored
lighting. The Colormix module features a 3-chip LED with high luminous
efficacy to achieve an infinite number of colors. Connectors are available for
both the flexible and rigid modules.
L
E
D
For all module dimensions see sylvania.com/led
297
080_LED.qxd
12/12/07
4:04 PM
Page 298
LED SYSTEMS CONTINUED…
LINEARlight Systems
Flexible LINEARlight reels are available with TOPLED or SIDELED options and
in a variety of colors. The LINEARlight MULTIFLEX provides new dimensions
for innovative lighting. POWERFLEX LINEARlight modules offer superior
lumen output for white light. The LINEARlight modules are mounted on rigid
boards which make them an ideal choice for small and sleek luminaires.
Optics and connectors are available for the rigid modules.
Accessories: connectors, optics, thermal solutions
Accessories to LED modules aid in a complete system solution. Connector
systems are designed to simplify the installation process by eliminating the
need to solder wires. Optic accessories provide light intensification and
mechanical protection. Thermal solutions supply proper thermal management
allowing for an optimal service life.
How to read Product Descriptions:
BACKlight2G
633
BL02ST
S1
BACKlight
Second
Generation
Wave
length
633nm
ID#
Color Code
S=Super Red
HF2Chain
36
W3
-865
HiFlux Second
Generation
Chain
# of
LED 36
Color
Code
W3=White
Color Temp
865=6500K
Color Definition
S,S1
A,A1
Y,Y1,Y2
O,O1
T.T2
B,B1
W,W2,W3
Super Red
Amber Red
Yellow
Orange
True Green
Blue
White
L
E
D
For all module dimensions see sylvania.com/led
298
080_LED.qxd
12/12/07
4:04 PM
Page 299
Safety Information for all LED modules and accessories
WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION.
TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE
POWER SUPPLIES AND/OR MODULES.
Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal,
State and local electric codes as well as the specific Underwriter’s Laboratories (UL) safety standards for the installation, location
and application may cause serious personal injury, death, property damage and/or product malfunction. These instructions are
guidelines for installation of OSRAM LED modules and power supplies. Installation requirements may vary depending on the
application. Licensed electricians should provide all installation services for connection of both primary and secondary (input/output)
of the power supplies.
1. The LED module itself and all its components must not be subjected to mechanical stress.
2. Assembly must not damage or destroy conducting paths on the circuit board.
3. Installation of LED modules (with power supplies) should adhere to all applicable electrical and safety standards. Only qualified
personnel should perform installations.
4. Correct electrical polarity needs to be observed. Wrong polarity may destroy the module.
5. Unbalanced voltage drop can cause hazardous overload and damage the LED module.
6. Ensure that the power supply is of adequate power to operate the total load.
7. Pay attention to standard ESD precautions when installing the module.
8. Damage by corrosion will not be honored as a materials defect claim. It is the user’s responsibility to provide suitable protection
against corrosive agents such as moisture, condensation and other harmful elements.
9. Modules may be hot to the touch. Use caution when handling.
10. Only install according to the heat sinking parameters outlined.
11. For applications involving exposure to humidity and dust, the module must be protected by a fixture or housing with a suitable
protection glass. The module can be protected against condensation water by treatment with an appropriate circuit board conformal
coating. The conformal coating should have the following features:
•
•
•
•
•
Optical transparency
UV resistance
Thermal expansion properties matching those of the module (15-30 x 10-6cm/cm/K)
Low permeability of steam for all climate conditions
Resistance against corrosive environments
Note: The “AFL” grade conformal coating from Electrolube, Inc. (www.electrolube.com) has met the conditions for LINEARlight
Colormix in our tests.
*For product specific safety information please see the appropriate Product Information Bulletin
The LED Module incorporates no protection against short circuits, overload or overheating. Therefore it is absolutely necessary to
operate the modules with an electronically stabilized power supply offering protection against the above mentioned safety risks.
OSRAM OPTOTRONIC power supplies are specifically designed with protection features for safe operation.
L
E
D
When using power supplies other than OPTOTRONIC the following basic safety features are required in addition to any other
application specific concerns and local safety codes:
• Short circuit protection
• Overload protection
• Overheat protection
• Correct output voltage, including consideration for ripple and spikes.
For all module dimensions see sylvania.com/led
299
080_LED.qxd
12/12/07
4:04 PM
Page 300
SPOT/FLOOD PRODUCTS
HF2Eye
Task lighting, Accent lighting, Outdoor and landscape lighting, Shelf lighting, Display case lighting, Vehicle cabin lighting, Solar powered
installations
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
OPTOTRONIC
Power Supply
Current
(Amps)
Load
Wattage
Beam
Angle
(Degrees)
Luminous
Intensity
264
White
3300K
Constant Current
.35
1.2
15
230
264
White
5400K
Constant Current
.35
1.2
15
310
Ordering Description
Pkg
Qty
Case
Qty
70199
HF2Eye/W3-833
6
70200
HF2Eye/W3-854
6
|
|
|
DRAGONPuck
Task lighting, Accent lighting, Outdoor and landscape lighting, Shelf lighting, Refrigerator and freezer display case lighting, Light box, Backlit
graphics, Edge lighting, Vehicle cabin lighting, Solar powered installations
| Product
| Number
|
Ordering Description
Pkg Case
Qty Qty
70107
DRAGONPUCK/OS/DP3/W2-854
1
70108
DRAGONPUCK/OS/DP3/W2-865
70120
DRAGONPUCK/OS/DP3/W2-847
70121
70122
Load
Current
(Amps)
Beam
Load
Angle
Luminous
Wattage (Degrees) Intensity (cd)
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
16
White
5400
3
Constant Current .35
3.6
20
285
1
16
White
6500
3
Constant Current .35
3.6
20
285
1
16
White
4700
3
Constant Current .35
3.6
20
285
DRAGONPUCK/OS/DP3/A1
1
16
Red
617
3
Constant Current .35
2.4
16
215
DRAGONPUCK/OS/DP3/B1
1
16
Blue
470
3
Constant Current .35
3.6
16
100
70123
DRAGONPUCK/OS/DP3/V1
1
16
Verde
505
3
Constant Current .35
3.6
16
285
70124
DRAGONPUCK/OS/DP3/Y1
1
16
Yellow
587
3
Constant Current .35
2.4
16
215
70142
DRAGONPUCK/OS/DP3/W2-733
1
16
White
3300
3
Constant Current .35
3.6
20
230
70167
DRAGONPUCK/OS/DP3/W3-733
1
16
White
3300
3
Constant Current .35
3.6
16
600
70168
DRAGONPUCK/OS/W3-847
1
16
White
4700
3
Constant Current .35
3.6
16
900
70169
DRAGONPUCK/OS/W3-854
1
16
White
5400
3
Constant Current .35
3.6
16
900
70170
DRAGONPUCK/OS/W3-865
1
16
White
6500
3
Constant Current .35
3.6
16
900
L
E
D
For all module dimensions see sylvania.com/led
300
|
|
|
080_LED.qxd
12/12/07
4:04 PM
Page 301
HFDisk
Task lighting, Accent lighting, Outdoor and landscape lighting, Shelf lighting, Display case lighting, Vehicle cabin lighting, Solar powered
installations
| Product
| Number
|
Ordering Description
Pkg Case
Qty Qty
70203
HFDisk/3/W2-733
10
70204
HFDisk/3/W2-847
10
Load
Current
(Amps)
|
|
|
Viewing
Load
Angle
Wattage (Degrees) Lumens
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
100
White
3300K
3
Constant Current .35
3.6
120
60
100
White
4700K
3
Constant Current .35
3.6
120
75
HF2X
Task lighting, Accent lighting, Outdoor and landscape lighting, Shelf lighting, Display case lighting, Vehicle cabin lighting, Solor powered
installations
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
OPTOTRONIC
Power Supply
Current
(Amps)
Load
Wattage
Radiance
Angle
(Degrees)
120
White
5400K
Constant Current
.35
1.2
120
15
120
White
5400K
Constant Current
.35
1.2
60
33
6
120
White
5400K
Constant Current
.35
1.2
12
675
6
120
White
5400K
Constant Current
.35
1.2
30
110
HF2X/120/W3-733
6
120
White
3300K
Constant Current
.35
1.2
120
10
HF2X/12/W3-733
6
120
White
3300K
Constant Current
.35
1.2
12
45
70193
HF2X/30/W3-733
6
120
White
3300K
Constant Current
.35
1.2
30
75
70190
HF2X/120/W3-847
6
120
White
4700K
Constant Current
.35
1.2
120
*
70189
HF2X/60/W3-847
6
120
White
4700K
Constant Current
.35
1.2
60
*
70174
HF2X/12/W3-847
6
120
White
4700K
Constant Current
.35
1.2
12
*
70176
HF2X/30/W3-847
6
120
White
4700K
Constant Current
.35
1.2
30
*
70194
HF2X/60/W3-733
6
120
White
3300K
Constant Current
.35
1.2
60
22
Ordering Description
Pkg
Qty
Case
Qty
70184
HF2X/120/W3-854
6
70191
HF2X/60/W3-854
6
70201
HF2X/12/W3-854
70202
HF2X/30/W3-854
70164
70192
Luminous
Intensity
|
|
|
L
E
D
For all module dimensions see sylvania.com/led
301
080_LED.qxd
12/12/07
4:04 PM
Page 302
HF2Flood
Down lighting, Accent lighting, Cove lighting, Outdoor and landscape lighting, Vehicle cabin lighting, Solar powered installations
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
OPTOTRONIC
Power Supply
Current
(Amps)
Load
Wattage
Radiance
Angle
(Degrees)
Luminous
Intensity
20
White
3300K
24 Vdc
.50
12
25
700
20
White
4700K
24 Vdc
.50
12
25
700
1
20
White
5400K
24 Vdc
.50
12
25
700
1
20
White
6500K
24 Vdc
.50
12
25
600
HF2Flood/38/CO06A/W3-733
1
20
White
3300K
24 Vdc
.50
12
38
***
HF2Flood/38/CO06A/W3-847
1
20
White
4700K
24 Vdc
.50
12
38
***
70257
HF2Flood/38/CO06A/W3-854
1
20
White
5400K
24 Vdc
.50
12
38
***
70258
HF2Flood/38/CO06A/W3-865
1
20
White
6500K
24 Vdc
.50
12
38
***
Ordering Description
Pkg
Qty
Case
Qty
70244
HF2Flood/25/CO06A/W3-733
1
70243
HF2Flood/25/CO06A/W3-847
1
70242
HF2Flood/25/CO06A/W3-854
70241
HF2Flood/25/CO06A/W3-865
70255
70256
|
|
|
LINEAR PRODUCTS
HF2Stick
Shelf lighting, Under cabinet lighting, Refrigerator and freezer case lighting, Cove lighting, Display lighting, Street lighting
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
6
White
5400K
6
24 Vdc
.50
12
120
375
383
6
White
6500K
6
24 Vdc
.50
12
120
375
383
Ordering Description
Pkg Case
Qty Qty
70232
HF2Stick/6/W3-854-11.8 IN
1
70215
HF2Stick/6/W3-865-11.8 IN
6
|
|
|
HF2Linear
Shelf lighting, Under cabinet lighting, Refrigerator and freezer case lighting, Cove lighting, Display lighting, Street lighting
L
E
D
| Product
| Number
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
6
White
6500K
6
24 Vdc
.50
12
30
270
268
6
6
White
5400K
6
24 Vdc
.50
12
30
270
268
1
6
White
3300K
6
24 Vdc
.50
12
30
270
268
1
6
White
4700K
6
24 Vdc
.50
12
30
270
268
|
Ordering Description
Pkg Case
Qty Qty
70250
HF2Linear/6/L30/W3-865-12.1 IN
6
70214
HF2Linear/6/L30/W3-854-12.1 IN
70178
HF2Linear/6/L30/W3-733-12.1 IN
70109
HF2Linear/6/L30/W3-847-12.1 IN
For all module dimensions see sylvania.com/led
302
|
|
|
080_LED.qxd
12/12/07
4:04 PM
Page 303
HF2Stick XB
Shelf lighting, Under cabinet lighting, Refrigerator and freezer case lighting, Cove lighting, Display lighting, Street lighting
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
50
White
2700K
4
24 Vdc
0.23
5.6
100
130
135
50
White
4100K
4
24 Vdc
0.23
5.6
100
150
156
50
White
6500K
4
24 Vdc
0.21
5.1
100
240
250
Ordering Description
Pkg Case
Qty Qty
70212
HF2StickXB/4/W3-727-11.5 IN
10
70225
HF2StickXB/4/W3-841-11.5 IN
10
70226
HF2StickXB/4/W3-865-11.5 IN
10
|
|
|
DRAGONstick
Shelf Lighting, Under cabinet lighting, Refrigerator and freezer lighting, Display case lighting
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
10
White
4700K
6
24 Vdc
0.35
8.5
120
200
208
10
White
4700K
12
24 Vdc
0.7
17
120
300
313
1
10
White
3300K
6
24 Vdc
0.35
8.5
120
120
125
1
10
White
3300K
12
24 Vdc
0.7
17
120
240
250
Ordering Description
Pkg Case
Qty Qty
70221
DRAGONstick/6/W3-847 11.5 IN
1
70128
DRAGONstick/OS/DS12/W2-847
1
70158
DRAGONstick/OS/DS6/W2-733
70180
DRAGONstick/OS/DS12/W2-733
|
|
|
LINEARlight Flex Top Colormix
Edge lighting, Accent lighting, Cove lighting, Color mixing, Controlled color sequencing, Custom color applications
| Product
| Number
|
70127
Ordering Description
Pkg
Qty
Case
Qty
LINEARFLEX TOP/OS/LM10L/B7RGB
1
8
Red Channel
Wavelength
/(CCT ˚K)
Load
Viewing Luminous
LEDs/ OPTOTRONIC Current Load
Angle Flux
Lumens
Module Power Supply (Amps) Wattage (Degrees)(Lumens) /foot
617nm
200
24 Vdc
0.5
12.1
120
213
|
|
|
16.3
Green Channel
525nm
200
24 Vdc
1
24
120
336
25.6
Blue Channel
467nm
200
24 Vdc
0.8
19.2
120
54
4.1
L
E
D
For all module dimensions see sylvania.com/led
303
080_LED.qxd
12/12/07
4:04 PM
Page 304
LINEARlight Flex Top Colormix
Edge lighting, Accent lighting, Cove lighting, Color mixing, Controlled color sequencing, Custom color applications
| Product
| Number
|
70229
Ordering Description
Pkg
Qty
Case
Qty
LNRFLXTPLM10LB8RGB213.1FT
1
8
Red Channel
Wavelength
/(CCT ˚K)
Load
Viewing Luminous
LEDs/ OPTOTRONIC Current Load
Angle Flux
Lumens
Module Power Supply (Amps) Wattage (Degrees)(Lumens) /foot
625nm
200
24 Vdc
0.5
12.1
120
385
|
|
|
29.4
Green Channel
525nm
200
24 Vdc
1
24
120
770
58.8
Blue Channel
467nm
200
24 Vdc
0.6
14.4
120
130
9.9
LINEARlight Colormix
Edge lighting, Accent lighting, Cove lighting, Color mixing, Controlled color sequencing, Custom color applications
| Product
| Number
|
Ordering Description
Pkg Case
Qty Qty
70080
LNRCLRMX/LM01M/RGB 1.48 FT
1
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
All Colors
cool white
30
24 Vdc
0.33
8
120
87
58
Red Channel
617nm
30
24 Vdc
0.075
1.8
120
32
21
Green Channel
525nm
30
24 Vdc
0.15
3.6
120
51
34
Blue Channel
470nm
30
24 Vdc
0.12
2.9
120
8
5
|
|
|
10
LINEARlight MULTI FLEX
Cove lighting, Edge lighting, Border marking, Commercial signs, Emergency and rescue signs, Path and contour marking, Backlighting complex contours, Refrigeration cases, Display shelves, Recessed lighting
L
E
D
| Product
| Number
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
10
White
8800K
96
24 Vdc
0.25
6
28
1
8
White
2700K
96
24 Vdc
0.25
6
45
83
26
1
8
White
6500K
96
24 Vdc
0.25
6
45
180
56
|
Ordering Description
Pkg Case
Qty Qty
70181
LLMULTIFLX/THN/W3-880-3.2 FT
1
70205
LLMULTIFLX/THN/W3-827-3.2 FT
70182
LLMULTIFLX/THN/W3-865-3.2 FT
For all module dimensions see sylvania.com/led
304
45
88
|
|
|
080_LED.qxd
12/12/07
4:04 PM
Page 305
LINEARlight
Escape route marker, Border marker, Walkways, Outlines
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
10
Super Red
633nm
32
10 Vdc
0.4
4.2
120
54
37
10
Amber Red 617nm
32
10 Vdc
0.4
4.2
120
86
59
1
10
Orange
606nm
32
10 Vdc
0.4
4.2
120
98
67
1
10
Yellow
587nm
32
10 Vdc
0.4
4.2
120
69
47
LINEAR/525/OS/LM01A/T2
1
10
True Green
525nm
32
10 Vdc
0.4
4.2
120
57
39
LINEAR/470/OS/LM01A/B1
1
10
Blue
469nm
32
10 Vdc
0.4
4.2
120
10
7
70111
LINEAR/LM01A/W2-847 1.47FT
1
10
White
4700K
32
10 Vdc
0.4
4.2
120
57
39
70112
LINEAR/LM01A/W2-854 1.47FT
1
10
White
5400K
32
10 Vdc
0.4
4.2
120
57
39
70113
LINEAR/LM01A/W2-865 1.47FT
1
10
White
6500K
32
10 Vdc
0.4
4.2
120
57
39
70265
LINEAR/LM01/W3-733 1.47FT
1
10
White
3300K
32
10 Vdc
0.4
4.2
120
68
46
Ordering Description
Pkg Case
Qty Qty
70044
LINEAR/633/OS/LM01A/S1
1
70007
LINEAR/615/OS/LM01A/A1
1
70083
LINEAR/610/OS/LM01A/O1
70006
LINEAR/587/OS/LM01A/Y2
70008
70009
|
|
|
LINEARlight POWER FLEX
Cove lighting, Edge lighting, Border marking, Commercial signs, Emergency and rescue signs, Path and contour marking, Backlighting complex contours, Refrigeration cases, Display shelves, Recessed lighting
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
8
White
4700K
120
24 Vdc
3
72
120
1400
152
1
8
White
5400K
120
24 Vdc
3
72
120
1400
152
1
8
White
6500K
120
24 Vdc
3
72
120
1400
152
LNRPWRFLX/LM10P/W3-733 9FT
1
1
White
3300K
120
24 Vdc
3
72
120
1300
144
LNRPWRFLX/LM10P/W3-727 9FT
1
1
White
2700K
120
24 Vdc
3
72
120
1300
144
Ordering Description
Pkg Case
Qty Qty
70137
LNRPWRFLX/LM10P/W3-847 9FT
1
70098
LNRPWRFLX/LM10P/W3-854 9FT
70138
LNRPWRFLX/LM10P/W3-865 9FT
70267
70268
|
|
|
L
E
D
For all module dimensions see sylvania.com/led
305
080_LED.qxd
12/12/07
4:04 PM
Page 306
LINEARlight FLEX TOPLED
Cove lighting, Edge lighting, Border marking, Commercial signs, Emergency and rescue signs, Path and contour marking, Backlighting complex contours, Refrigeration cases, Display shelves, Recessed lighting
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
1
Yellow
587nm
600
24 Vdc
3
72
120
1290
47
1
1
Amber Red 617nm
600
24 Vdc
3
72
120
1620
59
1
1
True Green
525nm
600
24 Vdc
3
72
120
675
25
1
1
Blue
469nm
600
24 Vdc
3
72
120
170
6
LNRFLXTP/LM10A/W2-847 27.5FT 1
1
White
4700K
600
24 Vdc
3.6
86.4
120
1290
47
LNRFLXTP/LM10A/W2-854 27.5FT 1
1
White
5400K
600
24 Vdc
3.6
86.4
120
1290
47
LNRFLXTP/LM10A/W2-865 27.5FT 1
1
White
6500K
600
24 Vdc
3.6
86.4
120
1290
47
LNRFLXTP/LM10A/W3-727 27.5FT 1
1
White
2700K
600
24 Vdc
3.6
86.4
120
1440
52
Ordering Description
Pkg Case
Qty Qty
70061
LNRFLXTP/587/LM10A/Y1 27.5FT
1
70135
LNRFLXTP/617/LM10A/A1 27.5FT
70063
LNRFLXTP/525/LM10A/T1 27.5FT
70064
LNRFLXTP/470/LM10A/B 27.5FT
70105
70089
70104
70266
|
|
|
LINEARlight FLEX SIDELED
Cove lighting, Edge lighting, Border marking, Commercial signs, Emergency and rescue signs, Path and contour marking, Backlighting complex contours, Refrigeration cases, Display shelves, Recessed lighting
| Product
| Number
|
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
Red
615nm
300
10 Vdc
1.5
15.75
120
117
8.5
Yellow
587nm
300
10 Vdc
2.25
23.63
120
405
29
Ordering Description
Pkg Case
Qty Qty
Color
70066
LNRFLXSD/615/LM11A/A 13.8FT
1
1
70067
LNRFLXSD/587/LM11A/Y 13.8FT
1
1
70068
LNRFLXSD/525/LM11A/T 13.8FT
1
1
True Green
528nm
300
10 Vdc
3
31.5
120
147
11
70069
LNRFLXSD/470/LM11A/B 13.8FT
1
1
Blue
470nm
300
10 Vdc
3
31.5
120
37
3
70070
LNRFLXSD/LM11A/W 13.8FT
1
1
White
x=0.32, y=0.31 300
10 Vdc
3
31.5
120
405
29
L
E
D
For all module dimensions see sylvania.com/led
306
|
|
|
080_LED.qxd
12/12/07
4:04 PM
Page 307
DRAGONtape
Task lighting. Underer cabinet lighting, Accent lighting, Cove lighting, Outdoor and landscape lighting, Refrigerator and freezer lighting, Light
box, Backlit graphics, Edge lighting, Vehicle cabin lighting, Solar powered installations
| Product
| Number
|
Ordering Description
Pkg Case
Qty Qty
70106
DRAGONtape/OS/DT6/W2-847
1
70099
DRAGONtape/OS/DT6/W2-854
70100
DRAGONtape/OS/DT6/W2-865
70151
70101
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
Constant Current .35
7.2
120
150
300
6
Constant Current .35
7.2
120
150
300
6
Constant Current .35
7.2
120
150
300
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
25
White
4700K
6
1
25
White
5400K
1
25
White
6500K
DRAGONtape/OS/DT6/W2-733
1
25
White
3300K
6
Constant Current .35
7.2
120
120
240
DRAGONtape/OS/DT6/A1
1
25
Red
617nm
6
Constant Current .35
4.8
120
108
216
70117
DRAGONtape/OS/DT6/Y1
1
25
Yellow
587nm
6
Constant Current .35
4.8
120
108
216
70118
DRAGONtape/OS/DT6/V1
1
25
Verde
505nm
6
Constant Current .35
7.2
120
150
300
70119
DRAGONtape/OS/DT6/B1
1
25
Blue
465nm
6
Constant Current .35
7.2
120
48
96
|
|
|
CHAIN PRODUCTS
HF2Chain
Backlighting advertising panels, Signs, Channel letters and displays, General lighting
| Product
| Number
|
70165
Ordering Description
Pkg Case
Qty Qty
HF2Chain/36/W3-865
1
10
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
White
6500K
36
24 Vdc
2.2
52
110
120
1320
|
|
|
L
E
D
For all module dimensions see sylvania.com/led
307
080_LED.qxd
12/12/07
4:04 PM
Page 308
BACKlight 2G BLO2
Backlighting advertising panels, Signs, Channel letters and displays, General lighting
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
5
Super Red
633nm
240
10 Vdc
3.6
38
120
490
16
5
Amber Red 617nm
240
10 Vdc
3.6
38
120
1180
37.5
1
5
Orange
606nm
240
10 Vdc
3.6
38
120
980
31
1
5
Yellow
587nm
240
10 Vdc
3.6
38
120
980
31
B2G/525/BL02ST/T2 31.5FT
1
5
Green
525nm
240
10 Vdc
3
32
120
430
14
B2G/470/BL02ST/B1 31.5FT
1
5
Blue
470nm
240
10 Vdc
3
32
120
100
3
70144
B2G/BL02ST/W2-865 31.5FT
1
5
White
6500K
240
10 Vdc
3.6
38
120
520
17
70271
B2G/BL02S/W3-854 31.5FT
1
5
White
5400K
240
10 Vdc
4.2
44
120
880
28
70272
B2G/BL02S/W3-865 31.5FT
1
5
White
6500K
240
10 Vdc
4.2
44
120
880
28
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Ordering Description
Pkg Case
Qty Qty
70235
B2G/633/BL02ST/S1 31.5FT
1
70175
B2G/617/BL02ST/A2 31.5FT
1
70236
B2G/606/BL02ST/O1 31.5FT
70237
B2G/587/BL02ST/Y2 31.5FT
70238
70239
|
|
|
BACKlight 2G BLO4
Backlighting advertising panels, Signs, Channel letters and displays, General lighting
| Product
| Number
|
Ordering Description
Pkg Case
Qty Qty
70173**
B2G/BL04ST/W2-865 15.75FT
1
5 reels White
6500K
240
10 Vdc
3.6
38
120
520
33
70172**
B2G/525/BL04ST/T2 15.75FT
1
5 reels Green
525nm
240
10 Vdc
3
32
120
430
27
70171**
B2G/470/BL04ST/B1
1
5 reels Blue
470nm
240
10 Vdc
3
32
120
100
6
70274
B2G/BL04S/W3-865
1
5 reels White
6500K
240
10 Vdc
4.2
44
120
880
55.9
L
E
D
For all module dimensions see sylvania.com/led
308
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Lumens
/foot
|
|
|
080_LED.qxd
12/12/07
4:04 PM
Page 309
BACKlight
Backlighting advertising panels, Signs, Channel letters and displays, General lighting
| Product
| Number
|
Color
Wavelength
/(CCT ˚K)
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Current
(Amps)
Viewing Luminous
Load
Angle
Flux
Wattage (Degrees) (Lumens)
Lumens
/foot
20
Super Red
633nm
32
10.5 Vdc
0.4
4.2
120
54
30
20
Amber Red 617nm
32
10.5 Vdc
0.4
4.2
120
54
30
1
20
Orange
606nm
32
10.5 Vdc
0.4
4.2
120
86
48
1
20
Yellow
587nm
32
10.5 Vdc
0.4
4.2
120
69
38
BACKLITE/525/LM03A/T 1.8FT
1
20
True Green
525nm
32
10.5 Vdc
0.4
4.2
120
57
31
BACKLITE/470/LM03A/B 1.8FT
1
20
Blue
470nm
32
10.5 Vdc
0.4
4.2
120
9
5
70102
BACKLITE/LM03A/W2-854 1.8FT
1
20
White
5400K
32
10.5 Vdc
0.5
5.3
120
69
38
70103
BACKLITE/LM03A/W2-865 1.8FT
1
20
White
6500K
32
10.5 Vdc
0.5
5.3
120
69
38
Ordering Description
Pkg Case
Qty Qty
70081
BACKLITE/633/LM03A/S 1.8FT
1
70011
BACKLITE/615/LM03A/A 1.8FT
1
70071
BACKLITE/610/LM03A/O 1.8FT
70012
BACKLITE/587/LM03A/Y 1.8FT
70013
70014
|
|
|
LINEARlight Colorpod
Edge lighting, Accent lighting, Cove lighting, Color mixing, Controlled color sequencing, Custom color applications
| Product
| Number
|
Ordering Description
Pkg Case
Qty Qty
Lens
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Wattage
Color
70210
LINEARlight Colorpod/Clear-36 FT
1
12
70211
LINEARlight Colorpod/Frosted- 36 FT 1
12
RGB
Clear
50
7.5 Vdc
25
RGB
Frosted
50
7.5 Vdc
25
|
|
|
* To be used only with OTCP power supplies and controls.
LINEARlight Colorpod XB
Edge lighting, Accent lighting, Cove lighting, Color mixing, Controlled color sequencing, Custom color applications
| Product
| Number
|
Ordering Description
70208
LINEARlight Colorpod XB/Frosted- 67 FT 1
70209
LINEARlight Colorpod XB/Clear- 67 FT 1
Pkg Case
Qty Qty
Color
Lens
LEDs/
Module
OPTOTRONIC
Power Supply
Load
Wattage
6
RGB
Frosted
50
12 Vdc
50
6
RGB
Clear
50
12 Vdc
50
|
|
|
L
E
D
*To be used only with OTCP power supplies and controls.
For all module dimensions see sylvania.com/led
309
080_LED.qxd
12/12/07
4:04 PM
Page 310
ACCESSORIES FOR SPOT/FLOOD PRODUCTS
Spot/Flood Thermal Management Solutions
Thermal management solutions for DRAGONpuck® and HFDisk modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Diameter (in.)
Height (in.)
70136
Heatsink/DRAGONpuck-50
1
50
3.5
0.79
|
|
ACCESSORIES FOR LINEAR PRODUCTS
HF2Stick - Linear Connector System
Compatible with HF2Stick and HF2Linear modules
|
|
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length (in.)
Type
70251
HF2Stick-Linear/Conn/2pin-input
10
500
20
Power Feed
70252
HF2Stick-Linear/Conn-4in
10
500
4
Board to Board
70253
HF2Stick-Linear/Conn-2in
10
500
2
Board to Board
HF2Stick Optical Solutions
Compatible with HF2 Stick and DRAGONstick modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Beam Angle (Degrees)
70159
LED/Optic/Spot/Lens-2
12
12
4
70160
LED/Optic/Wide/Sub Lens-15
12
144
30
70161
LED/Optic/Oval/Sub Lens- 4x27
12
144
±4 x ±27
70162
LED/Optic/Diffuser/Sub Lens-5
12
144
10
|
|
Thermal Management Solutions
L
E
D
Compatible with HF2Stick, HF2Stick XB, HF2Chain and DRAGONstick modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in. (mm)
Width in. (mm)
Height in. (mm)
70186
Heatsink/Linear/1 ft
1
25
12 (304.8)
2.5 (63.5)
0.72 (18.3)
For all module dimensions see sylvania.com/led
310
|
|
080_LED.qxd
12/12/07
4:04 PM
Page 311
HF2Stick XB Connector
Accessory to HF2Stick XB modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in (mm)
Width in (mm)
Height in (mm)
Wire Length
in (mm)
70197
HF2StickXB Connector/input conn
10
500
.57 (14.5)
.28 (7)
.34 (8.7
12 (305)
70196
HF2StickXB Connector/conn
10
500
.57 (14.5)
.28 (7)
.34 (8.7)
1.77 (45)
70195
HF2StickXB Connector/conn-12
10
500
.57 (14.5)
.28 (7)
.34 (8.7)
11.9 (303)
Width in (mm)
Height in (mm)
Wire Length
in (mm)
|
|
Colormix Connector System
Accesory to Colormix Rigid module
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in (mm)
70114
CLRMXCONN/LM4PIN/Feeder
10
500
0.29(7.3)
0.49(12.5)
0.43(11)
19.7 (500)
70110
CLRMXCONN/LMConn45
10
1000
2.35(59.6)
0.49(12.5)
0.43(11)
1.77 (45)
Case Qty
Length in (mm)
Width in (mm)
Height in (mm)
Wire Length
in (mm)
19.7 (550)
|
|
LINEARlight Rigid Connector Systems
Accesory to LINEARlight module
| Product
Number
|
Ordering Description
70115
LINEARCONN/LM2-PIN/Feeder
10
500
0.54(13.6)
0.24(6.1)
0.19(5)
70116
LINEARBBCONN/LMCONN
10
500
0.44(11.2)
0.24(6.1)
0.18(4.65)
70133
LINEARLIGHTCONN/LMCONN-50
10
500
0.54(13.6)
0.24(6.1)
0.19(5)
Pkg Qty
|
|
19.7 (500)
L
E
D
For all module dimensions see sylvania.com/led
311
080_LED.qxd
12/12/07
4:04 PM
Page 312
LINEARlight Optics
Accessory to LINEARlight modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in (mm)
Width in (mm)
Viewing
Angle (Degrees)
70072
LINEARLT Optics OS-OP4X1-20 + OS-LM01A
1
80
2.20(56)
0.47(12)
20/25
|
|
LINEARlight MULTI FLEX Mounting Accessories
Accessory for LINEARlight MULTI FLEX modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
70220
LLMULTIFLX/INSTALL-SCREWS
20
100
70207
LLMULTIFLX/INSTALLL-TOOL
1
10
70206
LLMULTIFLX/STR-CHANNEL - 3.2 FT**
5
5
1000
10.5
70187
LLMULTIFLX/THN/FLX-CHANNEL - 3.2 FT*
20
20
1000
9
70188
LLMULTIFLX/THN/STR-CHANNEL - 3.2 FT** 5
5
1000
10
16.5
Length
(mm)
External
Width (mm)
Internal
Width (mm)
Base
Width (mm)
18.5
8
20
9
7
7
8
20
Height (mm)
|
|
* Flex channel only used with 70181
**70206 and 70188 can be used with 70205 and 70182
LINEARlight FLEX Top Colormix Connector System
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in (mm)
Width in (mm)
Height in (mm)
Wire Length
in (mm)
70183
LM4PINFLEXCONNBPS
10
1000
0.48 (12.25)
0.65 (16.5)
0.2 (5)
19.69 (500)
70263
LM2CONN5FLEXCONNBB
10
2000
1.4 (34.5)
0.65 (16.5)
0.2 (5)
0.39 (10)
L
E
D
For all module dimensions see sylvania.com/led
312
|
|
080_LED.qxd
12/12/07
4:04 PM
Page 313
LINEARlight FLEX Connectors
Compatible with LINEARlight POWERFLEX, LINEARlight Flex TOPLED, and LINEARlight FLEXSIDE LED
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in (mm)
Width in (mm)
Height in (mm)
Wire Length
in (mm)
70269
LM2PINFLEXCONN
10
1000
0.48 (12.25)
0.65 (16.5)
0.2 (5)
19.69 (500)
70263
LM2CONN5FLEXCONNBB
10
2000
1.4 (34.5)
0.65 (16.5)
0.2 (5)
0.39 (10)
|
|
ACCESSORIES FOR CHAIN PRODUCTS
BACKlight Connector
Compatible with BACKlight, BACKlight B2G BL02, and BACKlight B2G BL04
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Height in (mm)
Width in (mm) Depth in (mm)
Strip Length
in (mm)
70126
BACKLITECONN/LM03A/CONN
100
1000
0.27 (6.86)
0.39 (9.9)
0.22 (5.6)
0.39 (9.9)
|
|
BACKlight Tape
Accessory to BACKlight, BACKlight 2G and LINEARlight Rigid modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in (mm)
Width in (mm)
Depth in (mm)
70125
BACKlite Tape/OS/LM03A
40
400
1(25.4)
0.4 (10.16)
0.1 (2.54)
|
|
LINEARlight Colorpod Mounting Accessories
Accessories to LINEARlight Colorpod modules
| Product
Number
|
Ordering Description
Pkg Qty
Case Qty
Length in (mm)
70216
LINEARLlight Colorpod/Track- 4ft (Mounting track - 4ft)
1
50
4 ft
70217
LINEARlight Colorpod/Clip (Mounting Clip)
50
1000
-
Case Qty
Length in (mm)
|
|
L
E
D
LINEARlight Colorpod XB Mounting Accessories
Accessories to LINEARlight Colorpod XB modules
| Product
Number
|
Ordering Description
70218
LINEARLlight Colorpod XB/Track- 4ft (Mounting track - 4ft) 1
50
4 ft
70219
LINEARlight Colorpod XB/Clip (Mounting Clip)
1000
-
Pkg Qty
50
|
|
For all module dimensions see sylvania.com/led
313
088_LUM_LETR.qxd
12/12/07
4:08 PM
Page 314
CONSUMER LUMINAIRES
SYLVANIA Consumer Luminaires offer consumer and professional products to both new and existing markets that incorporate advanced,
innovative LED technology.
The consumer luminaires product portfolio includes:
SYLVANIA
Bright White LED light™
Meet the bright, long-lasting light that you can stick practically anywhere—over and over. DOT-it bright white LED lights
outperform incandescent tap lights in brightness and life. This
small, versatile light can be placed in a diverse range of locations to help provide bright, white light where needed. Use
it in your car behind the seatback, in your home as an under
cabinet light, in your workshop or garden shed, for your
child’s backpack or on your boat.
MOBILE & FUNCTIONAL LIGHTING
SYLVANIA Portable Lighting Products (Lanterns,
Flashlights, Reading Lights, Safety Lights and more)
are as durable as they are attractive, and go anywhere you
do. Put them in your backpack or suitcase. On your bike. In
your car. Take them to the beach, the mountains or use them
around the house. Whatever activity you enjoy—hiking,
camping, boating, cycling or working on the house, let
SYLVANIA portable lights light the way for you. They’re
perfect as safety and emergency lights, too.
SYLVANIA LED Strip Lights
bring colored light and lighting effects to alcoves, task areas, accent areas and other tight spaces without the expense or constraints of
conventional colored lighting methods. The soft-edge fixture design is available in fixed lengths and three LED colors. Each LED strip light
comes with a power cord, connection cord and mounting screws and brackets. The housing snaps into mounting brackets; no need to open
the case to mount the strip. And, LED fixtures can be connected to one another to form longer lighting strips.
SYLVANIA Night Lights
are as functional as they are decorative. They provide just the right amount of light needed for visibility and peace-of-mind. No need to light
up an area unnecessarily—wasting energy. SYLVANIA Night Lights can be used just about anywhere you need the perfect little light:
bedroom, bathroom, kitchen, entryway/hallway, basement, garages, utility room, hotel rooms and nursing homes.
MOOD & DECORATIVE LIGHTING
L
U
M
I
N
I
A
R
E
S
SYLVANIA MOSAIC™ Color Changing Products
Color your world, indoors and out, with SYLVANIA MOSAIC Color Changing Products. They brighten up any application and make every
occasion a special one. These innovative LEDs combine bright, colorful light with long lasting, durable LED technology. SYLVANIA MOSAIC
products are currently available as SYLVANIA LED Light Chains, and SYLVANIA Night Lights.
SYLVANIA lightingBrilliance™ –
LED Recessed Lights
require no maintenance and are shock and vibration-resistant—providing long service life. Each recessed luminaire is equipped with four
long-life LEDs in either white or blue with a lightly frosted lens. The mounting ring, available in stainless steel or granite, beautifully
complements any décor or surrounding. Electronic power supplies to operate 10V LED fixtures are included in the LED Recessed Lighting
Starter Kit. Installed in walls, floors or ceilings, they are ideal for living rooms, bathrooms and for marking out walkways, gardens or patios.
Used indoors or outdoors, SYLVANIA LED recessed lighting can enhance the design of your retail, hospitality, residential or office application.
SYLVANIA LED Light Chains
can make so many applications more festive and unique everyday. Party on, outdoors on the patio or deck, with Light Chains. Give one to
your favorite student for their dorm room. Light up your landscape. Highlight treasured items in a cabinet or display case. Whenever and
wherever you want your lighting to look spectacular, use a SYLVANIA LED Light Chain. Available with cool-white or color changing LEDs.
Please visit www.sylvania.com or contact your local SYLVANIA Sales Representative for the most up-to-date listings of our Consumer
Luminaires products
314
088_LUM_LETR.qxd
12/12/07
4:08 PM
Page 315
LED RETROFIT LAMPS
LED Retrofit Lamps fill the niche for LED replacements for traditional incandescent or halogen S14, PAR20 and MR16 lamps. LED technology
offers substantially better improved energy savings and exceptionally long life. They are ideal where temperature extremes and difficult or
hard-to-reach locations are a factor with conventional light sources.
Contact your local SYLVANIA Sales Representative of the most up-to-date lists of LED Retrofit products.
Par20
S14
MR16
LED RETROFIT LAMPS – PAR20
Symbols &
| Product
| Number Footnotes Ordering Code
72100
72101
72102
72103
1,2,3
1,2,3
1,2,3
1,2,3
PAR20/36/36LED/Y/FL
PAR20/36/36LED/R/FL
PAR20/36/36LED/B/FL
PAR20/36/36LED/G/FL
LED RETROFIT LAMPS – S14
Symbols &
| Product
| Number Footnotes Ordering Code
72090
72091
72092
72093
72094
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
S14/30LED/G
S14/30LED/B
S14/30LED/R
S14/30LED/Y
S14/30LED/RGB
LED
Finish
Green
Blue
Red
Yellow
Color Changing
LED RETROFIT LAMPS – MR16
Symbols &
| Product
| Number Footnotes Ordering Code
72098
72099
72084
72085
72086
3
3
3
3
3
LED
Finish
Red
Yellow
Blue
Green
Wattage
1.6
1.6
1.1
1.1
0.9
Max. Luminous
Intensity (cd)
LED/MR16/DRAGON/W/730/NSP6/CLAM
869
LED/MR16/DRAGON/W/735/NSP6/CLAM
955
LED/MR16/DRAGON/W/730/NSP6/COUNTER 869
LED/MR16/DRAGON/W/735/NSP6/COUNTER 955
LED/MR16/DRAGON/W/B/NSP6/COUNTER
303
Wattage
2.0
2.2
1.5
1.5
Voltage
120V
120V
120V
120V
Voltage
120V
120V
120V
120V
120V
MOL (in.)
3.15
3.15
3.15
3.15
3.15
Color
Temp. (K)
3000
3500
3000
3500
470
Wattage
2.8
2.8
2.8
2.8
2.8
MOL (in.)
3.25
3.25
3.25
3.25
Beam
Angle
Flood
Flood
Flood
Flood
Cover
Finish
Acrylic Soft White
Acrylic Soft White
Acrylic Soft White
Acrylic Soft White
Acrylic Soft White
Voltage
12V
12V
12V
12V
12V
MOL(in.)
2
2
2
2
2
Base
Medium
Medium
Medium
Medium
Units
per Case
12
12
12
12
|
|
Base
Medium
Medium
Medium
Medium
Medium
Units
per Case
15
15
15
15
15
|
|
Beam
Angle
6
6
6
6
6
Units
per Case
6
6
6
6
6
|
|
FOOTNOTES FOR LED RETROFIT LAMPS
Footnote
Description
1.
CAUTIONS
•
This lamp is not intended for use in emergency light fixtures or exit lights
•
Not for use with dimmers
•
No user serviceable parts inside. To avoid electrical shock, do not disassemble lamp
•
Risk of electrical shock – do not use where directly exposed to water
2.
Please contact your local SYLVANIA Sales Representative for a most updated product list on LED Retrofit Lamps
3.
To avoid electrical shock and early lamp failure, this lamp must only be used indoors and in dry locations
•
No user serviceable parts inside. To avoid electrical shock, do not disassemble lamp
•
This lamp is not intended for use in emergency light fixtures or exit signs
•
LED MR16 lamps will not dim. The lamps will extinguish at lower dimmer settings. Dimming circuits will not harm the lamps
•
LED MR fits most standard, low voltage MR16 lighting fixtures including: track, strips for case lighting,
adjustable downlighting, landscape lighting and recessed lighting
•
LED MR16 lamps are not compatible with integral electronic transformers; LED MR16 lamps can run on magnetic transformers only
•
Please contact your local SYLVANIA Sales Representative for most updated product lists on LED Retrofit Lamps
L
E
D
R
E
T
R
O
F
I
T
315
090_Warr.qxd
12/12/07
4:09 PM
Page 316
SYLVANIA HID SYSTEM
LIMITED WARRANTY
Combination Lamp and Ballast System Limited Warranty
OSRAM SYLVANIA Products Inc. (“OSPI”) warrants SYLVANIA
lamps installed on SYLVANIA magnetic ballasts to be free from
defects in material and workmanship and to operate from the date
of installation (or 3 months from date of manufacture if installation
date is not known or available) for the lamp and ballast warranty
System
METALARC®
METALARC®
LUMALUX®
LUMALUX®
Avg. Rated Lamp Life*
7,000-12,000 hrs
15,000-20,000 hrs
24,000 hrs
30,000 hrs
TERMS AND CONDITIONS
SYLVANIA lamps and SYLVANIA ballasts must be installed
together as a system and be installed and operated under suitable environmental conditions and in accordance with the latest
National Electrical Code, Underwriters Laboratory Bulletins, and
ANSI Specifications. This warranty will not apply in the event of
conditions demonstrating abnormal use or stress, such as operating temperatures in excess of maximum rated temperatures,
under/over voltage conditions, excessive switching cycles or
operating hours, dirty or cracked sockets, or improper lamp or
ballast installation. Replacement of SYLVANIA lamps with lamps
of other manufacturers will void the lamp portion of this warranty.
Replacement of the SYLVANIA ballast with any other ballast will
void the entire warranty.
FURTHER CONDITIONS
1. Warranty periods based on a minimum 4,000 hours/year
to a maximum 6,000 hours/year operation (minimum
10hr/start for lamp).
2. The lighting system must operate the lamp within current
ANSI Specifications.
3. OSRAM SYLVANIA reserves the right to examine all failed
lamps to verify cause of failure and shall be the sole judge as
to whether the lamps are in fact defective.
4. System warranty valid only for installations of 50 or more
lamps and ballasts. Contact OSRAM SYLVANIA for further
details.
5. Check with OSRAM SYLVANIA when using occupancy sensors or dimming, as some situations may void the warranty.
WARRANTY ACTIVATION / SERVICE CLAIMS
W
A
R
R
A
N
T
I
E
S
QUESTIONS?
Lamp Warranty Period
6 months
12 months
12 months
24 months
For more complete product information visit www.sylvania.com
Ballast Warranty Period
24 months
24 months
24 months
24 months
The HID System warranty is automatically activated after
OSPI receives a completed HID System warranty registration
form within 30 days after installation. An acknowledgment
will be sent for each registration along with a reference number for future correspondence. Service claims can be made
by contacting 1-800-LIGHTBULB to initiate the process for
problem resolution.
LABOR OPTIONS
No labor allowance is made for lamp or ballast replacement.
RETURN OF DEFECTIVE PRODUCT
After contacting OSRAM SYLVANIA and receiving a
RETURN MATERIAL AUTHORIZATION NUMBER, the
user shall promptly return the product at the user’s expense
to OSRAM SYLVANIA after receiving instructions as to if,
when and where to ship product. Failure to follow this procedure shall void this warranty.
REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY
The foregoing shall constitute the sole and exclusive remedy
of the purchaser and the sole and exclusive liability of OSPI.
NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED.
OSPI will not, under any circumstance, whether as a result of
breach of contract or warranty, tort, or otherwise, be liable for
any incidental, special or consequential damages, including
lost profits or revenues or any other costs or damages.
OSPI reserves the right to examine all failed lamps and/or
ballasts and reserves the right to be the sole judge as to
whether any lamps and/or ballasts are defective and covered
under this warranty.
*Subject to and limited by the lamp warranty period limitations set forth above.
Please call customer service at 1-800-654-0089
or contact your local OSRAM SYLVANIA representative.
HID043
316
periods and subject to the Terms and Conditions specified below.
If lamps fail to operate for the warranty period, OSPI will provide a
free replacement lamp (no labor allowance). If a SYLVANIA magnetic ballast fails to operate within the warranty period, OSPI will
provide a free replacement ballast (no labor allowance).
090_Warr.qxd
12/12/07
4:09 PM
Page 317
The Heart of a Comprehensive System Service Program
QUICK 60+®
Limited Warranty
Subject to change without notice.
Compare lighting system warranties – you’ll see that our QUICK 60+ warranty
offers better coverage, more service options and, more important, peace of mind.
Combination Lamp and Ballast System Limited Warranty
OSRAM SYLVANIA Products Inc. (“OSPI”) warrants SYLVANIA lamps installed on
QUICKTRONIC® ballasts to be free from defects in material and workmanship and
to operate from the date of installation (or date of manufacture if installation date is
not known or available) for the time periods and subject to the Terms and Conditions
System3,4
QUICKTRONIC® T81
QUICKTRONIC T81
QUICKTRONIC T8 High Ambient1, 9
QUICKTRONIC 59
QUICKTRONIC 59
QUICKTRONIC 86/T8HO High Ambient1
QUICKTRONIC 96IS/96HO & 40T12
QUICKTRONIC T51, T5/HO1
QUICKTRONIC 54T5HO1 High Ambient
QUICKTRONIC 54T5/HO1
QUICKTRONIC 54PHO & DL40
QUICKTRONIC CF1
QUICKTRONIC FM
QUICKTRONIC ICE1, 5
QUICKTRONIC MH7
QUICKTRONIC MH7
*
1
2
3
4
5
6
7
8
9
specified below. If lamps fail to operate for the warranty period, OSPI will provide a
free replacement lamp (but no labor allowance). If a QUICKTRONIC ballast fails to
operate within the warranty period, OSPI will provide a free replacement ballast and
labor allowance in accordance with the “Labor Options” set forth below.
Lamp
Ballast Warranty Period*8
Lamp Warranty Period*
OCTRON XPS®, XP & XP/SS2, 3
60 mos.
36 mos.
OCTRON family
60 mos.
30 mos.
2, 3
OCTRON XP, XP/SS
36/60mos.@<90°/70°C
36 mos.
OCTRON FO96/XP, FO96/XP/SS
60 mos.
30 mos.
OCTRON FO96
60 mos.
24 mos.
OCTRON FO96HO
36/60mos.@<90°/70°C
30 mos.
N/A
60 mos.
N/A
®
PENTRON Family
60 mos.
24 mos.
®
PENTRON FP54/HO, FP54/C/HO
36/60 mos.@<90°/70°C
36 mos.
PENTRON® FP54/HO, FP54/C/HO
60 mos.
36 mos.
®
DULUX FT55DL, FT40DL & FT40/28SS
60 mos.
12 mos.
DULUX® D/E, T/E, T/E/IN, T/E/C
60 mos.
12 mos.
FM
24 mos.
6 mos.
®
ICETRON
60 mos.
60 mos.
®
6
METALARC Family (7K-12K hrs. avg. rated life)
36/60 mos.
6 mos.
METALARC® Family6 (15K-20K hrs. avg. rated life)
36/60 mos.
12 mos.
NOTE: Fluorescent lamp warranty periods are based on a 3 hour minimum cycle, unless otherwise noted, with a maximum of 4000 hours per year. Other
operating cycles may affect warranty period. Lamp warranty can renew when installation is group relamped, contact OSRAM SYLVANIA for details.
Occupancy sensor application, 15 minute/start minimum, allowed with QUICKTRONIC PROStart® and with QUICKTRONIC ICE ballasts.
OCTRON SUPERSAVER® bipin lamps operate on Instant Start & PROStart (non-dimming) models only.
QUICKTRONIC, Professional Series and High Efficiency Series including all IS, PS & DIM models where applicable.
Labor options must be pre-approved by OSPI. Any labor option or cost that is not pre-approved will not be eligible for reimbursement.
ICETRON Lamp Warranty Period allows up to 8760 hrs per year (continuous operation).
Contact OSRAM SYLVANIA for detailed specifications of METALARC® lamps.
QUICKTRONIC MH ballasts warranty is 36 or 60 months, depending on maximum case temperature. Refer to product specifications for details. Electronic HID
system warranty period is based on a minimum cycle of 10hr/start up to a maximum operation of 6,000 hours/year.
Maximum Case Temperature <70°C, for normal environmental operating conditions (40°C max. ambient) unless noted.
Refer to product specifications for details.
QUICKTRONIC T8 High Ambient (HT) Series
TERMS AND CONDITIONS
SYLVANIA lamps and QUICKTRONIC ballasts must be installed together as a
system and be installed and operated under suitable environmental conditions
and in accordance with the latest National Electrical Code, Underwriters
Laboratory Bulletins, and ANSI Specifications. This warranty will not apply in
the event of conditions demonstrating abnormal use or stress, such as
operating temperatures in excess of maximum rated temperatures,
under/over voltage conditions, excessive switching cycles (see above Note
#1) or operating hours, dirty or cracked sockets, or improper lamp or
ballast installation. Replacement of SYLVANIA lamps with lamps of other
manufacturers will void the lamp portion of this warranty. Replacement of the
QUICKTRONIC ballast with any other ballast will void the entire warranty.
WARRANTY ACTIVATION / SERVICE CLAIMS
The QUICK 60+ warranty is automatically activated after OSPI receives
a completed QUICK 60+ warranty registration form within 30 days after
installation. An acknowledgment will be sent for each registration along
with a reference number for future correspondence. Service claims can
be made by contacting 1-800-LIGHTBULB to initiate the process for
problem resolution.
LABOR OPTIONS (Ballast and ICETRON lamps only)
No labor allowance is made for any lamp replacement except ICETRON,
during the warranty period. OSPI provides for several labor options for service
under the QUICK 60+ warranty program.
1. OSPI will provide full service coverage through SYLVANIA LIGHTING
SERVICES at no cost to the user of the ballast, or
2. OSPI will contact a service provider and coordinate replacement at no
cost to the user of the ballast, or
3. OSPI will reimburse the purchaser reasonable, customary and necessary
labor charges required to install the ballast replacement.
4. Labor options must be pre-approved by OSPI. Any labor option or cost
that is not pre-approved will not be eligible for reimbursement.
RETURN OF DEFECTIVE PRODUCT
After contacting OSRAM SYLVANIA and receiving a return
AUTHORIZATION NUMBER, the user shall promptly return the product at
the user’s expense to OSRAM SYLVANIA after receiving instructions as to
if, when and where to ship product. Failure to follow this procedure shall
void this warranty.
REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY
The foregoing shall constitute the sole and exclusive remedy of the
purchaser and the sole and exclusive liability of OSPI. NO WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS
MADE OR IS TO BE IMPLIED. OSPI will not, under any circumstance,
whether as a result of breach of contract or warranty, tort, or otherwise,
be liable for any incidental, special or consequential damages, including
lost profits or revenues or any other costs or damages.
W
A
R
R
A
N
T
I
E
S
OSPI reserves the right to examine all failed lamps and/or ballasts and
reserves the right to be the sole judge as to whether any lamps and/or
ballasts are defective and covered under this warranty.
call customer service at 1-800-654-0089 or contact
QUESTIONS? Please
your local OSRAM SYLVANIA representative.
For more complete product information visit www.sylvania.com
317
090_Warr.qxd
12/12/07
4:09 PM
Page 318
QUICK 60+® LIMITED
WARRANTY
Registration Form
Subject to change without notice.
Photocopy the form below and use it to register any installation featuring QUICKTRONIC® ballast systems. Also available, is our on-line
version which you may find by visiting our web site at www.sylvania.com. The warranty coverage begins from the date of installation, but
you must register an installation in order to receive warranty service.
Installation Information
Location Name:______________________________________________________________________________________________
Address:______________________________________City:___________________________State:______________Zip:_________
Send Registration To: _________________________________________________________________________________________
Address:______________________________________City:___________________________State:______________Zip:_________
Contact Name: _________________________________Phone:_________________________Email: _________________________
Installation Date: ___________________________________
Operating Hours: ___________________________________hours/day ______________________days/year
Occupancy Sensors:
Comments
Yes
No
______________________________________________________________________________________________
Type &Quantities (Description and NAED Item # as Shown on label (or packaging)
Ballast
NAED
Lamp
NAED
Description
Item #
Quantity
Description
Item #
Quantity
Comments
_____________________________________________________________________________________________________________________________
e.g. QTP2X32T8/UNV ISN-TC
49943
800
FO32/830/XP/ECO
21759
1600
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
W
A
R
R
A
N
T
I
E
S
_____________________________________________________________________________________________________________________________
Please Complete and Return To:
OSRAM SYLVANIA
Or Complete and Fax To:
OSRAM SYLVANIA
Attn: Warranty Dept.
18725 N. Union Street, Westfield, IN 46074
Tel #: 800/654-0089 Email: warranty.service@sylvania.com
Fax #: 866/632-9674
OSRAM SYLVANIA National Customer Service and Sales Center
www.sylvania.com
For more complete product information visit www.sylvania.com
318
090_Warr.qxd
12/12/07
4:09 PM
Page 319
Magnetic Ballast Limited Warranty
OSRAM SYLVANIA Products Inc. (“OS”) warrants SYLVANIA fluorescent magnetic ballasts and high intensity discharge (HID) magnetic
ballasts to be free from defects in material and workmanship and to
Magnetic Ballast Type
Fluorescent Magnetic
High Intensity Discharge (HID) Magnetic
Magnetic Sign
operate from the date of manufacture for the time periods specified
below.
Ballast Warranty Period*
36 months
24 months
24 months
*Note - Warranty periods are based on typical 4000 hr/12 months operation; longer operating cycles may limit warranty period.
Contact OS for details.
TERMS AND CONDITIONS
SYLVANIA magnetic fluorescent and HID ballasts must be installed
and operated under suitable environmental conditions and in accordance with the latest National Electrical Code, Underwriters
Laboratory Bulletins, ANSI Specifications, CSA standards, and in
accordance with OS installation instructions, where applicable. This
warranty will not apply if conditions demonstrate abnormal use or
stress, such as operating temperatures in excess of maximum rated
temperatures, under/over voltage conditions, excessive switching
cycles or operating hours, dirty or cracked sockets, or improper lamp
or ballast installation.
WARRANTY ACTIVATION / SERVICE CLAIMS
Warranty is activated after installation. Service claims can be made by
contacting 1-800-654-0089 (press “2”) to initiate the process for
problem resolution.
REPLACEMENT OF PRODUCT
OS shall correct any defects by replacing or repairing, at OS’s option,
any ballast determined to be defective under the terms of this warranty. Note: Labor costs are not reimbursed by OS.
QUESTIONS?
RETURN OF DEFECTIVE BALLAST
After contacting OS and receiving a return AUTHORIZATION NUMBER, the purchaser may be requested to promptly return the ballast
at the purchaser’s expense to OS after receiving instructions as to if,
when and where to ship the ballast. Failure to follow this procedure
shall void this warranty.
LIMITS OF LIABILITY
The foregoing shall constitute the sole and exclusive remedy of the
purchaser and the sole and exclusive liability of OS. NO IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED. OS will not, under
any circumstance, whether as a result of breach of contract or warranty, tort, or otherwise,be liable for any costs or damages, including
lost profits or revenues, incidental, special or consequential damages.
OS reserves the right to examine all failed ballasts and reserves the
right to be the sole judge as to whether any ballasts are defective and
covered under this warranty. This warranty does not cover lamps
operated by the ballast.
Please call customer service at 1-800-654-0089
contact your local OSRAM SYLVANIA representative.
W
A
R
R
A
N
T
I
E
S
For more complete product information visit www.sylvania.com
319
090_Warr.qxd
12/12/07
4:09 PM
Page 320
OSRAM SYLVANIA Products, Inc. (OSI) is pleased to provide the following
warranty for the periods shown below. This warranty covers OSI’s LED Modules and
Optotronic® Power supplies or controls when installed as a system.
LED SYSTEM WARRANTY
Limited Warranty
OSI LED System Limited Warranty
OSI warrants each OSI LED Module or Optotronic‚ Power supply
or control to be free from defects in materials and workmanship,
and to operate from the date of installation (or date of manufacturer if installation date is not known or available, or verifiable)
for the time periods and subject to the Terms and Conditions
specified below. If an OSI LED module or an Optotronic‚ Power
supply or control fails to operate for the specified warranty period, OSI will provide a free replacement component in accordance with the Terms and Conditions set forth below (labor not
included).
OSRAM LED SYSTEMS FOR LIGHTING WARRANTY
LED Module
Family
Power Supply and
Control Warranty Period
LED Module
Warranty Period
BACKlight, LINEARlight,
LINEARlight Flex, (Colormix),
EFFECTlight, COINlight,
MARKERlight
60 months
60 Months
System4
Optotronic‚ OT and
OSRAM LED Lamp
Modules, Power Supply
or Controls
TERMS AND CONDITIONS
WARRANTY SERVICE CLAIMS
This warranty only applies when OSI’s OSRAM LED Lamp Module
is properly wired and installed; is operated on a suitable power
supply within the electrical values recommended by OSI; used in
lighting equipment designed and approved for the application and
in environmental conditions (temperature, humidity) within the
normal specified operating range of the system. This warranty
does not apply to any abnormal use or use in violation of any
applicable standard, code or instructions for use in installations
including those contained in the latest National Electrical Code
(NEC), the Standards for Safety of Underwriters Laboratory, Inc.
(UL), Standards for the American National Standards Institute
(ANSI) or, in Canada, the Canadian Standards Association (CSA).
This warranty will not apply in the event of conditions demonstrating abnormal use or stress, including under/over
voltage/current conditions, excessive switching cycles or operating hours or outside the following recommended operating conditions:
Warranty claims can be serviced by calling OSI’s National
Customer Service & Sales Center:
• Warranty Period is based on typical 8,760 hr./yr.
operation on a continuous burning cycle of 24
hours.
• Mean operating temperature for LED Module: 25˚C
• Maximum operating temperature for LED Module:
65˚C
• Operate at rated DC Voltage
• Mean ambient operating temperature for
Optotronic‚ Power supplies and controls is 40˚C
W
A
R
R
A
N
T
I
E
S
Replacement of OSI LED Module components with LED components of other manufacturers will void the entire warranty.
Inappropriate use and selection of power supply will void the
entire warranty.
QUESTIONS?
If you are unsure whether a situation exists that is covered by
this warranty, please contact OSI’s National Customer Service &
Sales Center for assistance.
RETURN OF DEFECTIVE PRODUCT
After contacting OSI, the purchaser/user shall promptly return
the product after receiving instructions regarding if, when and
where to ship product. Failure to follow this procedure shall void
this warranty.
REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY
The foregoing shall constitute the exclusive remedy of the purchaser and the sole liability of OSI for the OSI LED Lamp Module
component and Optotronic‚ power supply or controls. NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED. In no event shall
OSI be liable for any other costs or damages, including lost profits or revenues, incidental, special or consequential damages.
OSI reserves the right to examine all failed OSI Module LED and
Optotronic‚ power supply, controls and components to determine the cause of failure and patterns of usage and reserves the
right to be the sole judge as to whether any such controls or
components are defective and covered under this warranty.
Please call customer service at 1-800-654-0089
or contact your local OSRAM SYLVANIA representative.
For more complete product information visit www.sylvania.com
320
1-800-654-0089
Fax: 866-632-9674
Email: warranty.service@sylvania.com
090_Warr.qxd
12/12/07
4:09 PM
Page 321
LIMITED PRODUCT WARRANTY HBO® SEMICONDUCTOR LAMPS
OSRAM SYLVANIA INC. (OSI) warrants that its HBO OSRAM mercury short arc lamp (HBO Lamp) for microlithography will be in conformity
with OSI published specifications and free from defects in material and workmanship. In the event a non conformity or defect causes a catastrophic (non-passive) failure which results in damage to customer's Stepper machine during the average rated life of the HBO Lamp, customer's sole and exclusive remedy will be reimbursement for actual direct expenses incurred by the customer for parts, materials and outside labor for the repair of the damaged Stepper, up to a maximum of $1.5 million per occurrence. As a precondition of such reimbursement, customer must notify OSI within 10 days of the catastrophic failure; make available the HBO Lamp for testing; allow, if requested, the
inspection of the damaged Stepper machine; and provide such other documentation or information as OSI may reasonably require to review
and process customer's claim, including an itemized proof of loss with supporting documentation and invoices. This limited warranty shall
be void if a catastrophic lamp failure results from accident, abuse, misuse, misapplication or occurs during operation of the HBO Lamp
beyond its average rated life or during operation of a Stepper machine beyond its operating specifications.
EXCEPT AS EXPRESSLY SET FORTH HEREIN, THERE ARE NO OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILTY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO
THE HBO LAMP.
OSI'S SOLE LIABILITY TO CUSTOMER, AS A RESULT OF THE SALE OR USE OF THE HBO LAMP, IS LIMITED TO THE REIMBURSEMENT
REMEDY DETAILED ABOVE. IN NO EVENT WILL OSI BE LIABLE TO THE CUSTOMER, OR ITS CUSTOMERS, AFFILIATES OR DISTRIBUTORS FOR ANY LOST PROFITS, LOST SAVINGS, DOWN TIME, INABILITY TO USE CUSTOMER'S STEPPER MACHINE, OR FOR ANY OTHER
CONSEQUENTIAL, DIRECT, INDIRECT, SPECIAL, EXEMPLARY AND PUNITIVE DAMAGES OR FOR ANY OTHER DAMAGES OF ANY KIND OR
NATURE.
For purposes of notification to OSI, send all requested information, including invoices and other supporting documentation to:
Quality Department
OSRAM SYLVANIA
c/o Danzas AEI
8470 Gravista Street
El Paso, TX 79907
Phone: 915-775-2939
Fax: 915-775-2924
W
A
R
R
A
N
T
I
E
S
SEE THE WORLD IN A NEW LIGHT
For more complete product information visit www.sylvania.com
321
110_index.qxd
12/18/07
12:55 PM
Page 322
Index
INCANDESCENT LAMPS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Lamp Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Bulb Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Filaments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Lamp Shapes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Reading Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Incandescent Brand Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
eLogic
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Daylight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8
Double Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-11
General Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-29
Decorative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29-34
Traffic Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Symbols & Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35-39
Manufacturers' Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
TUNGSTEN HALOGEN LAMPS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Filaments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Bases
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Bulb Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Reading Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
ANSI Beam Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Tungsten Halogen Brand Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
CAPSYLITE A-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
BT15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Decorative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Tubular T10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Daylight PLUS PAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Soft White Halogen PAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
CAPSYLITE PAR Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
CAPSYLITE PAR14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
CAPSYLITE PAR16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47-48
CAPSYLITE IR PAR20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
CAPSYLITE PAR20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
CAPSYLITE IR PAR30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
CAPSYLITE PAR30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
CAPSYLITE PAR30 Longneck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-51
CAPSYLITE IR PAR38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51-52
CAPSYLITE PAR38 lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52-55
CAPSYLITE Cool Lux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Large PAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
CAPSYLITE G9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
SUPER Q Single End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56-57
Double End Quartz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57-58
OSRAM MINISTAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Bi-Pin IR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
STARLITE Bi-Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Standard Bi-Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
24V Bi-Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
TRU-AIM MR16 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
TRU-AIM IR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
TRU-AIM TITAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60-61
TRU-AIM BRILLIANT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
TRU-AIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61-62
TRU-AIM MR11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
SIRIUS MR16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
I
N
D
E
X
For more complete product information visit www.sylvania.com
322
CAPSYLITE PAR36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
AR70 Aluminum Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
AR111 Aluminum Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Symbols & Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64-68
Manufacturers' Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69-71
MINIATURE LAMPS
Miniature Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72 -74
Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
HIGH INTENSITY DISCHARGE LAMPS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75-76
Reading Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Bulb Shapes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Bases
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Operating Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
HID Brand Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Lamp Disposal Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Metal Halide Lamp Construction & Families . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Metal Halide Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81-86
HPS Lamp Construction & Families . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
HPS & LPS Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Mercury Vapor Lamp Construction & Familes . . . . . . . . . . . . . . . . . . . . . . . . .89
Mercury Vapor Lamp Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Reprographic Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Reprographic Lamps Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
POWERBALL Ceramic METALARC Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
POWERBALL Ceramic METALARC Tubular Single End . . . . . . . . . . . . . .91
POWERBALL Ceramic METALARC Tubular Double End . . . . . . . . . . . . .91
POWERBALL Ceramic METALARC PAR . . . . . . . . . . . . . . . . . . . . . . .91-92
POWERBALL Ceramic METALARC E17 & Hi Wattage . . . . . . . . . . . .92-93
METALARC PULSE START & PRO-TECH Lamps . . . . . . . . . . . . . . . . . . . . . . .93
METALARC PULSE START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93-94
METALARC PRO-TECH PULSE START . . . . . . . . . . . . . . . . . . . . . . . . .94-95
METALARC PRO-TECH PULSE START PAR . . . . . . . . . . . . . . . . . . . . . . .95
METALARC PRO-TECH SUPERSAVER . . . . . . . . . . . . . . . . . . . . . . . . . . .95
METALARC PRO-TECH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95-96
METALARC SUPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
METALARC SUPERSAVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96-97
METALARC STANDARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
METALARC SAFELINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
METALARC BRITELINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
HQI Metal Halide Double Ended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
HQI Fiber Optic Dichroic Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
HQI Metal Halide Single End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
LUMALUX High Pressure Sodium Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . .98
LUMALUX PLUS & LUMALUX PLUS ECO . . . . . . . . . . . . . . . . . . . . .98-99
LUMALUX Standard & LUMALUX ECO . . . . . . . . . . . . . . . . . . . . . . . . . . .99
LUMALUX Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Specialty HPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Mercury Vapor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Low Pressure Sodium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Symbols & Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101-102
Manufacturers' Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103-106
110_index.qxd
12/18/07
12:55 PM
Page 323
Index (continued)
COMPACT FLUORESCENT LAMPS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Reading Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
DULUX Lamp Families . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Lamp Disposal Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Lamp Colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Competitive Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Brand Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Color Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Bulb Shapes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
Bases
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
DULUX Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112-113
DULUX Pin Base CFLs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
DULUX S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
DULUX S/E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
DULUX D ECO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
DULUX D/E ECO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
DULUX T ECO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
DULUX T/E ECO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116-117
DULUX T/E/IN Amalgam ECO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117-118
DULUX L ECO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118-119
DULUX F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
DULUX EL Self Ballasted CFLs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Mini Twist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119-120
Twist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
Classic A-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
Decorative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121-122
Globe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122-123
DURA-ONE Electrodeless CFLs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
Low Profile Bullet and Circline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
Symbols & Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124
Manufacturers' Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125-127
FLUORESCENT LAMPS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
Reading Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
Lamp Disposal Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
Lamp Colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Competitive Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132-133
Brand Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
Color Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
Fluorescent Electrical Interchangeability . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133
Bulb Shapes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
Bases
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
OCTRON & OCTRON CURVALUME T8 Fluorescent Lamps . . . . . . . . . . . . .135
OCTRON 800 XPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
OCTRON 800 XP 4' SUPERSAVER . . . . . . . . . . . . . . . . . . . . . . . . . .135-136
OCTRON 800 XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136-137
OCTRON 700 XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
OCTRON 800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137-138
OCTRON 700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138-139
OCTRON 800 XP 8' SUPERSAVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
OCTRON 800 XP 8' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
OCTRON 800 8' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
OCTRON 700 8' . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
OCTRON 800 XP SUPERSAVER CURVALUME-1 5/8" Leg Spacing . . .140
OCTRON 800 XP CURVALUME-1 5/8" Leg Spacing . . . . . . . . . . . . . . . .140
OCTRON CURVALUME-1 5/8" Leg Spacing . . . . . . . . . . . . . . . . . . .140-141
OCTRON 800 XP SUPERSAVER CURVALUME-6" Leg Spacing . . . . . .141
OCTRON 800 XP CURVALUME-6" Leg Spacing . . . . . . . . . . . . . . . . . . .141
OCTRON 800 CURVALUME-6" Leg Spacing . . . . . . . . . . . . . . . . . . . . . .141
OCTRON 700 CURVALUME-6" Leg Spacing . . . . . . . . . . . . . . . . . .141-142
OCTRON 5000K & 6500K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
OCTRON Specialty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
PENTRON T5 Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
PENTRON High Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
PENTRON Premier High Performance . . . . . . . . . . . . . . . . . . . . . . . . . . .143
PENTRON High Output, High Performance . . . . . . . . . . . . . . . . . . . . . . .144
PENTRON High Output, Wide Temp Range . . . . . . . . . . . . . . . . . . . . . . .144
PENTRON Circline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
3' SUPERSAVER Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
3' Standard Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
4' SUPERSAVER Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145-146
4' Standard Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146-147
CURVALUME SUPERSAVER Rapid Start-6" Leg Spacing . . . . . . . . . . .147
CURVALUME Standard Rapid Start-6" Leg Spacing . . . . . . . . . . . .147-148
Circline T9 Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
High Output (800mA) SUPERSAVER Rapid Start . . . . . . . . . . . . . . . . . .148
High Output (800mA) Standard Rapid Start . . . . . . . . . . . . . . . . . .148-150
High Output (800mA) Rapid Start for Cold Temp Operation . . . . . . . . .150
Very High Output (1500mA) SUPERSAVER Rapid Start . . . . . . . . . . . .150
Very High Output (1500mA) Standard Rapid Start . . . . . . . . . . . . . . . . .150
Instant Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
Slimline SUPERSAVER Instant Start . . . . . . . . . . . . . . . . . . . . . . . . .150-151
Slimline Standard Instant Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151-152
Preheat Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
Miniature T5 Preheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
Standard T8 & T12 Preheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153-154
Specialty Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154
SAFELINE Shatter Resistant Coated Lamps . . . . . . . . . . . . . . . . . . .154-155
Weather Shielded Jacketed Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155
GRO-LUX Plant & Aquarium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155
Miniature T2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155-156
ICETRON Inductively Coupled Electrodeless . . . . . . . . . . . . . . . . . . . . . .156
ICETRON Inductively Coupled Electrodeless Reflector . . . . . . . . . . . . . .156
Diazo SDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Blacklight Preheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Blacklight Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Blacklight Blue Preheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Blacklight Blue Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Germicidal Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Germicidal Compact Fluorescent . . . . . . . . . . . . . . . . . . . . . . . . . . . .157-158
Germicidal Preheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Germicidal Instant Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Germicidal Amalgam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Fluorescent Preheat Lamp Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
GLOStat Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158-159
COP Starters With Cutout & Manual Reset . . . . . . . . . . . . . . . . . . . . . . .159
Symbols & Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160-165
Manufacturers' Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166-169
For more complete product information visit www.sylvania.com
323
I
N
D
E
X
110_index.qxd
12/18/07
12:55 PM
Page 324
Index (continued)
ELECTRONIC & MAGNETIC BALLASTS,
LED POWER SUPPLIES
TABLE OF CONTENTS ELECTRONIC BALLASTS . . . . . . . . . . . . . . . . . . . . . .173
The System Solution and Product Families . . . . . . . . . . . . . . . . . . . . . . .172-175
QUICKTRONIC Electronic Fluorescent, CFL & HID Ballasts . . . . . . . . . .176-184
LED Power Supplies & Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Discontinued Electronic Ballasts & Replacement List . . . . . . . . . . . . . .186-187
QUICKCROSS Manufacturers' Cross Reference . . . . . . . . . . . . . . . . . .188--193
TABLE OF CONTENTS MAGNETIC BALLASTS . . . . . . . . . . . . . . . . . . . . . . . .195
Magnetic Ballasts Introduction & Product Information . . . . . . . . . . . . .194-197
Magnetic Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198-205
DISPLAY/OPTIC LAMPS
Lamp Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207
Display/Optic Halogen Lamps
Upgrades for Popular Projection Lamps . . . . . . . . . . . . . . . . . . . . . . . . .208
Lamp Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
OSRAM Airfield Lamp Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209
OSRAM AluPAR Lamp Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210
Audiovisual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211-215
Studio.Theater, TV & Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215-218
STTV Large PAR-ALUPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218
STTV Large PAR-Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .218-219
Special Purpose Heat Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
Optoelectronics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
Aircraft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219-220
Airfield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220-221
Display/Optic Discharge Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222
4ArXS Lamp Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222
SharXS HTI Lamp Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223
HMI Single End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225-226
HMI Double End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227-228
HTI Single End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229
HTI SharXS Double End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230-231
HTI Baby SharXS Double End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
HTI Double End-Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233
HTI w/ Dichroic Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234
HSR w/ Outer Jacket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235
HSD 4ArXS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236
XBO <= 450W Xenon Short Arc . . . . . . . . . . . . . . . . . . . . . . . . . . . .237-240
XBO >450W Xenon Short Arc Cinema Projection . . . . . . . . . . . . . .241-252
XSTAGE Xenon Short Arc Entertainment . . . . . . . . . . . . . . . . . . . . . . . . .253
HBO Mercury Short Arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254-256
HXP Mercury Short Arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257
HBO Mercury Short Arc Microlithography . . . . . . . . . . . . . . . . . . . .258-267
VIP Video & Data Projection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268
Spectral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .269
Excimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270
Display/Optic Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271
Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271-273
Operating Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .274
Footnotes & Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275-281
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282-285
DISPLAY OPTIC Lamp Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . .286-295
I
N
D
E
X
For more complete product information visit www.sylvania.com
324
LED SYSTEMS
Introduction & Product Families . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297-298
Reading Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .298
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299
Spot/Flood Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300
HF2 Eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300
DRAGONPuck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300
HF Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .301
HF2X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .301
HF2 Flood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .302
Linear Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .302
HF2 Stick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .302
HF2 Linear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .302
HF2 Stick XB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
DRAGONstick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
LINEARlight Flex Top Colormix . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303-304
LINEARlight Colormix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304
LINEARlight Multi Flex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304
LINEARlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305
LINEARlight Power Flex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305
LINEARlight FLEX TOPLED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .306
LINEARlight FLEX SIDELED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .306
DRAGONtape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .307
Chain Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .307
HF2 Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .307
BACKlight 2G BL02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308
BACKlight 2G BL04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .308
BACKlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309
LINEARlight Colorpod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309
LINEARlight Colorpod XB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309
Spot/Flood Product Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
Thermal Management Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
Linear Product Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
HF2 Stick Linear Connector System . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
HF2 Stick Optical Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
Thermal Management Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
HF2 Stick XB Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311
Colormix Connector System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311
LINEARlight Rigid Connector Systems . . . . . . . . . . . . . . . . . . . . . . . . . . .311
LINEARlight Optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312
LINEARlight Multi Flex Mounting Accessories . . . . . . . . . . . . . . . . . . . . .312
LINEARlight Flex Top Colormix Connector System . . . . . . . . . . . . . . . . .312
LINEARlight Flex Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313
Chain Product Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313
BACKlight Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313
BACKlight Tape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313
LINEARlight Colorpod Mounting Accessories . . . . . . . . . . . . . . . . . . . . .313
LINEARlight Colorpod XB Mounting Accessories . . . . . . . . . . . . . . . . . .313
110_index.qxd
12/18/07
12:55 PM
Page 325
Index (continued)
CONSUMER LUMINAIRES
Introduction & Product Families . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314
LED RETROFIT LAMPS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315
PAR20 Retrofit Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315
S14 Retrofit Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315
MR16 Retrofit Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315
Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .315
SYSTEM WARRANTIES
HID System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316
QUICK 60+ System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317-318
Magnetic System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319
LED System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320
HBO Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321
I
N
D
E
X
For more complete product information visit www.sylvania.com
325
110_index.qxd
12/18/07
12:55 PM
Page 326
Notes:
I
N
D
E
X
For more complete product information visit www.sylvania.com
326
www.sylvania.com
Note:
OSRAM SYLVANIA LTD./LTÉE
2001 Drew Road
Mississauga, Ontario L5S 1S4
OEM/Special Markets
Phone: 800-762-7191
Fax:
800-762-7192
National Accounts
Phone: 800-562-4671
Fax:
800-562-4674
Industrial Commercial
Phone: 800-255-5042
Fax:
800-255-5043
Consumer Products
Phone: 800-842-7010
Fax:
800-842-7011
Display/Optic
Phone: 888-677-2627
Fax:
800-762-7192
OEM/Special Markets
Phone: 800-265-2852
Fax:
800-667-6772
Industrial Commercial
Phone: 800-263-2852
Fax:
800-667-6772
Consumer Markets
Phone: 800-720-2852
Fax:
800-667-6772
Display/Optic
Phone: 800-265-2852
Fax:
800-667-6772
SYLVANIA LIGHTING
SERVICES:
Phone: 800-663-4268
Fax:
866-239-1278
SYLVANIA LIGHTING
SERVICES:
Phone: 800-323-0572
Fax:
978-750-2784
CAPSYLITE, CAPSYLITE IR, CURVALUME, DAYLIGHT, DAYLIGHT PLUS, DESIGNER, DESIGN 50, DESIGNER PLUS, Dot-It, DURA-ONE, ECO, ECOLOGIC, elogic, EXCEL-LINE,
Fixtureside Assistance, GRO-LUX, HALOGEN PLUS, HALOGEN XTRA, HELIOS, ICETRON, LINESTRA, LUMALUX, LUMALUX PLUS, METALARC, METALARC PRO-TECH,
OCTRON, PENTRON, POWERBALL, POWERSENSE, PROSTART, QUICKSENSE, QUICK 60+, RHINOCOAT, SAFELINE, SPOT-GRO, SUNSTICK, SUPERSAVER, SUPERSAVER
PLUS, SYLVANIA, The System Solution and Squiggle Logo, TRU-AIM, TRU-AIM BRILLIANT, TRU-AIM TITAN, UNALUX, XP and XPS are trademarks or registered
trademarks of OSRAM SYLVANIA.
Printed on recycled paper. 1/08
Mexico
OSRAM MEXICO
Headquarters
TuItitlan/Edo DeMexico
011-52-55-58-99-18-50
www.sylvania.com
OSRAM SYLVANIA
National Customer
Service and Sales Center
18725 N. Union Street
Westfield, IN 46074
Lamp and Ballast Catalog
© 2008 OSRAM SYLVANIA
Canada
OSRAM SYLVANIA LTD./LTÉE
Headquarters
2001 Drew Road
Mississauga, Ontario L5S 1S4
1-800-LIGHTBULB
www.sylvania.com
For Orders and
General Information
in Canada:
Lamp and Ballast Catalog
United States
OSRAM SYLVANIA
Headquarters
100 Endicott Street
Danvers, MA 01923 USA
1-800-LIGHTBULB
www.sylvania.com
For Orders and
General Information
in the United States:
Certain photography
At the time of printing, new wattages of SYLVANIA Incandescent A19, Medium Screw
Base, 120 Volt and 130 Volt lamps with Soft White, Inside Frost and Clear finishes have
been developed to meet new State of California standards effective January 1, 2008
but are not yet listed in this catalog. For more information on the legislation and these
new lamps, please visit www.sylvania.com. Click on State Product Regulations.
AluPAR, BELLAPHOT, DRAGON, DULUX, HBO, HLX, HMD, HMI, HMP, HPR, HQI, HSD, HSR, HTI, HXP, SharXS, GLOBAL CARE, LINEX, MINISTAR, OPTOTRONIC, OStar,
OSRAM, P-VIP, QUICKTRONIC, SUPERPHOT, STUDIOLINE, VIP, XBO, XENOPHOT, XERADEX and Xstage are trademarks or registered trademarks of OSRAM GmbH.
All other trademarks contained herein not owned by OSRAM SYLVANIA or its subsidiaries, are the property of their respective owners.
CATALOG08
L&B_Cover_Lot A.indd
1
1/3/08
6:37:52 AM