03 Pg A49 A60.qxp 111090 Catalog

120593-Brochure 120593-Brochure 120593-Brochure 050169 Batch7 unilog cesco-content

2014-07-04

: Pdf 111090-Catalog 111090-Catalog 050169 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 12

CATALOG NO. KNOCKOUTS CU. STD. UPC
NUMBER OF TOP &* SIDES* BACK IN. PKG. BAR
GANGS B0TT0M CODE
941 2 4-3/4", 4-conc. 4-conc. 3-1/2", 2-3/4" 70.0 5
942 3 8-3/4", 2-conc. 4-conc. 6-1/2", 4-3/4" 90.0 5
943 4 4-3/4", 4-conc. 4-conc. 6-1/2", 4-3/4" 110.0 5
944 5 6-3/4", 4-conc. 4-conc. 6-1/2", 4-3/4" 130.0 5
945 6 6-3/4", 6-conc. 4-conc. 6-1/2", 4-3/4" 150.0 1
951 2 8-conc. 4-conc. 3-1/2", 2-3/4" 47.0 5
952 3 10-conc. 4-conc. 6-1/2", 4-3/4" 60.0 5
953 4 12-conc. 4-conc. 6-1/2", 4-3/4" 72.8 5
954 5 14-conc. 4-conc. 6-1/2", 4-3/4" 85.8 5
955 6 16-conc. 4-conc. 6-1/2", 4-3/4" 98.5 1
956 7 18-conc. 4-conc. 6-1/2", 4-3/4" 111.5 1
957 8 20-conc. 4-conc. 6-1/2", 4-3/4" 124.5 1
958 9 22-conc. 4-conc. 6-1/2", 4-3/4" 137.3 1
Application
Gang boxes are used where a num-
ber of wiring devices are to be
centrally located
Product Features
Gang boxes save time in installation,
no need to gang boxes together
Have 1/2" and 3/4" concentric
KO’s for use with a wide variety of
wiring methods
Bottom KO pattern, 3-1/2" and 2-3/4"
at either end of box
Accept two styles of covers, flat and
3/4" raised device cover
Device covers also fit next smaller
box, i.e. three-gang cover fits two or
three-gang box
Use low voltage partitions
#974 or #949
941 through 945
*1-5/8" deep boxes, concentric KO’s are 1/2" & 3/4" *2-1/2" deep boxes, concentric KO’s are 3/4" & 1"
CATALOG NO. OF A B C
NUMBER GANGS
941 2 2-1/2" 6-3/8" 6-13/16"
942 3 2-1/2" 8-3/16" 8-5/8"
943 4 2-1/2" 10" 10-7/16"
944 5 2-1/2" 11-13/16" 12-1/4"
945 6 2-1/2" 13-5/8" 14-1/16"
951 2 1-5/8" 6-3/8" 6-13/16"
952 3 1-5/8" 8-3/16" 8-5/8"
953 4 1-5/8" 10" 10-7/16"
954 5 1-5/8" 11-13/16" 12-1/4"
955 6 1-5/8" 13-5/8" 14-1/16"
956 7 1-5/8" 15-7/16" 15-7/8"
957 8 1-5/8" 17-1/4" 17-11/16"
958 9 1-5/8" 19-1/16" 19-1/2"
STEEL GANG BOXES
d^kd=_lubp
o^`l=pqbbi=_lubp=
C=`lsbop
A49
NJRLUÒ=^ka=OJNLOÒ=abbm
loabofkd=fkcloj^qflk=J=afjbkpflkp
951 through 958
GANG BOXES – 1-5/8" & 2-1/2” DEEP – WELDED
WITH CONDUIT KO’S
DIMENSIONS
Compliance
– File E195978
4714, THE INSIDER® will secure nonmetallic sheathed cable in 1/2” KO (See pg. B87)
03 Pg A49-A60.qxp 6/9/2008 9:07 AM Page A49
A50 `lsbop=^ka=m^oqfqflkp
o^`l=pqbbi=_lubp=
C=`lsbop
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG NO. OF WIDTH CU. IN. STD. UPC
NUMBER GANGS PKG. BAR CODE
821 2 7-1/16" 10.0 5 —
822 3 8-7/8" 15.3 5
823 4 10-11/16" 20.3 5
824 5 12-1/2" 25.5 5 —
825 6 14-5/16" 30.5 1 —
826 7 16-1/8" 35.5 1 —
827 8 17-15/16" 40.8 1 —
828 9 19-3/4" 45.8 1 —
CATALOG STD. UPC
NUMBER DESCRIPTION PKG. BAR CODE
974 For 1-5/8” Deep 25
949 For 2-1/2” Deep 25
Application
Gang box covers permit the mounting
of devices
Product Feature
Device covers also fit next smaller
box, i.e. three gang cover fits two or
three gang box
Compliance
ÓFile E195978 (Cat. #974
and 949 not UL Listed)
823 974
LOW VOLTAGE PARTITION FOR GANG BOXES
DEVICE COVERS FOR GANG BOXES RAISED 3/4"
846
CATALOG NO. OF WIDTH CU. IN. STD. UPC
NUMBER GANGS PKG. BAR CODE
844 2 7-1/16" 5 —
845 38-7/8" —5
846 4 10-11/16" 5 —
847 512-1/2" —1
848 6 14-5/16" 1 —
849 716-1/8" —1
850 8 17-15/16" 1 —
851 9 19-3/4" 1 —
FLAT, BLANK COVERS FOR GANG BOXES
949
03 Pg A49-A60.qxp 6/9/2008 9:07 AM Page A50
pqbbi=`lk`obqb=ofkdp
o^`l=pqbbi=_lubp=
C=`lsbop
A51
KNOCKOUT SIZE A B
1/2” and 3/4” KOs 1/2” 3/4”
3/4” and 1” KOs 3/4” 1”
CATALOG DESCRIPTION CU. STD. UPC BAR
NUMBER IN. PKG. CODE
280 3/8” x 1/2” Long stud, 8-1/2”, 8-3/4” KO’s* 43.0 20
918 30” Long bars for hung ceiling box 40
CATALOG DEPTH KO NO. CU. STD. UPC
NUMBER SIZES ROWS IN. PKG. BAR
KO’S CODE CEILING FAN FIXTURE
(DYNAMIC) LBS. (STATIC) LBS.
270RAC 2” 1/2” & 3/4” Single 24.5 25 No 50
271 2-1/2” 1/2” & 3/4” Single 30.8 25 No 50
272 3” 1/2” & 3/4” Single 37.0 25 No 50
277 3” 3/4” & 1” Single 37.0 25 No 50
273 3-1/2” 1/2” & 3/4” Double 43.0 20 No 50
278 3-1/2” 3/4” & 1” Single 43.0 20 No 50
274 4” 1/2” & 3/4” Double 49.3 20 No 50
279 4” 3/4” & 1” Double 49.3 20 No 50
275 5” 1/2” & 3/4” Double 61.5 10 No 50
276 6” 1/2” & 3/4” Double 74.0 10 No 50
284* 4” 1/2” & 3/4” Double 49.3 6 35 75
Applications
Concrete rings are used with poured
deck (floor) in high-rise construction
These boxes are installed on wooden
or steel concrete forms. After the
forms are removed, the box is flush
with the concrete
RACO®Ceiling Fan Concrete Ring 284
is listed for support of ceiling fans
Product Features
Flat sides provide excellent contact
for locknuts
External ears are used to nail the ring
to the wood form
The top cover is removable for
before-pour work
Ears on inside of box are for fixtures
Waxed fixture ears prevent concrete
from interfering with the threads
Variety of cover plates are available
Cover plate must be ordered sepa-
rately with all (except 280 which
includes a 891 cover) RACO®
concrete rings
KNOCKOUT LOCATIONS
HUNG CEILING BOX – 3-1/2" DEEP
*Order bars separately
890 891 893892
CATALOG DESCRIPTION KNOCKOUTS O.D. STD. UPC
NUMBER DIAM. PKG. BAR CODE
890 3-1/2”, 2-3/4” 4-1/2” 25
891 3/8” Stud 2-1/2”, 2-3/4” 4-1/2” 25
892 Flat, blank 4-1/2” 25
893 Joins Oct. Ext. ring to concrete ring 4-1/2” 50
Includes two retained screws
*280 shown with 918 BARS
284 GORILLA-RING
270RAC, 271, 272, 273, 274,
275, 276, 277, 278, 279
STEEL CONCRETE RINGS
loabofkd=fkcloj^qflk=J=afjbkpflkp
RECOMMENDED MAX.
SUPPORT LOAD
CONCRETE RINGS
CONCRETE RING – BACK PLATES/COVERS AND ADAPTER RING
Compliance
– File E195978
*Ceiling Fan Support Box
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A51
A52 j^plkov=_lubp=^ka=m^oqfqflkp
o^`l=pqbbi=_lubp=
C=`lsbop
OJNLOÒ=^ka=PJNLOÒ=abbm
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG NO. OF WIDTH KNOCKOUTS CU. STD. UPC BAR
NUMBER GANGS (B) ENDS BOTTOM SIDES IN. PKG. CODE
690 1 1-31/32" 2 conc. 2 conc. 4 conc. 16.0 25
691 2 3-25/32" 4 conc. 4 conc. 4 conc. 31.8 25
692 3 5-19/32" 6 conc. 3 conc. 4 conc. 47.8 10
693 4 7-13/32" 8 conc. 4 conc. 4 conc. 63.5 10
694 5 9-7/32" 10 conc. 5 conc. 4 conc. 79.5 10
960 6 11-1/32" 12 conc. 6 conc. 4 conc. 95.3 1
Applications
Masonry boxes are designed to accom-
modate the mounting of switches or
other devices in masonry walls
Gangable masonry boxes offer the
option of constructing a box to hold two
or more devices
2-1/2" deep boxes are used in 4” block
walls, 3-1/2” deep boxes are used in 6”
or 8” block walls
Non-Gangable Product Features
Rugged welded construction does not
fall apart during construction
Available from one to six gang configu-
rations in both 2-1/2" and 3-1/2" depths
Rectangular shape fits square cuts in
block
Large volume design allows for addi-
tional work room inside the box
Standard 1/2” and 3/4” concentric
knockouts
Device ears are formed inside the box,
preventing mortar from getting in the
device holes
Steel low voltage partition: 971 fits all
2-1/2” or 3-1/2” depths (non-gangable
versions only)
Standard wall plates cover the box
Gangable Product Features
Rugged design does not fall apart dur-
ing construction
Gangable design allows installer to build
unlimited number of gangs to hold mul-
tiple devices
Rectangular shape fits square cuts in block
Standard 1/2”- 3/4” TKO®knockouts
Device ears are formed inside the box,
preventing mortar from getting in the
device holes
Steel low voltage partitions: 675 fits 2-
1/2” deep box, 676 fits 3-1/2” deep box
Forward mounted grounding provision
allows for easy installation of ground-
ing pigtail
Standard wall plates cover the box
Compliance
– File E195978 (Cat. #971
not UL Listed) STEEL MASONRY
BOXES 691, 696
690 691 692
971
696
697
695, 8695
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
FOR NON-GANGABLE MASONRY BOXES
971 For 2-1/2" or 3-1/2" deep boxes 25
FOR GANGABLE MASONRY BOXES
675 For 2-1/2" deep boxes 20
676 For 3-1/2" deep boxes 20
CATALOG NO. OF WIDTH KNOCKOUTS CU. STD. UPC BAR
NUMBER GANGS (B) ENDS BOTTOM SIDES IN. PKG. CODE
695 1 1-31/32" 4 conc. 2 conc. 4 conc. 22.5 25
8695 1 1-31/32" 4 conc. 2 conc. 4 conc. 22.5 25
696 2 3-25/3 2" 8 conc. 4 conc. 4 conc. 45.0 25
697 3 5-19/3 2" 12 conc. 3 conc. 4 conc. 67.3 10
698 4 7-13/3 2" 16 conc. 4 conc. 4 conc. 89.8 10
699 5 9-7/3 2" 20 conc. 5 conc. 4 conc. 112.3 10
965 6 11-1/3 2" 24 conc. 6 conc. 4 conc. 134.8 1
LOW VOLTAGE PARTITION FOR MASONRY BOXES
MASONRY BOXES – 2-1/2" DEEP – NONGANGABLE WITH CONDUIT KO’S
MASONRY BOXES – 3-1/2" DEEP – NONGANGABLE WITH CONDUIT KO’S
675, 676 688, 689
CATALOG NO. OF DEPTH WIDTH KNOCKOUTS CU. STD. UPC BAR
NUMBER GANGS (B) ENDS BOTTOM SIDES IN. PKG. CODE
688 1 2-1/2” 1-15/16” 2 TKO®2 TKO®4 TKO®15.5 20
689 1 3-1/2” 1-15/16” 4 TKO®. 2 TKO®4 TKO®22.5 20
MASONRY BOXES – GANGABLE WITH CONDUIT KO’S
4714, THE INSIDER® will secure nonmetallic sheathed cable in 1/2” KO (See pg. B87)
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A52
rkfsbop^i=molqb`qlo=mi^qbp
o^`l=pqbbi=_lubp=
C=`lsbop
A53
clo=rpb=tfqe=jraofkdp=J=mltbo
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications
Eliminates drywall compound, debris,
paint, and drywall router bit from entering
box or damaging conductors or devices
Available in raised or flat versions
Raised covers all DecoraTM, duplex and
switch wiring devices
Flat close off mudring opening and pro-
tect wires from drywaller’s router bit tools
Product Features
Covers entire opening of mudring
No hardware required for use - simply
snaps on and off standard mudring
Durable steel construction allows cover
to be used multiple times
Holes in cover allow for use of screws
to prevent theft and add additional
security (screws not included)
Recessed tab allows cover to be easily
removed using pliers, side cutters or
flat screw driver
Reference Data
Patent 7,102,079
701R 702R
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701R To protect 1 device / for 1 device mudring* 24
702R To protect 2 devices / for 2 device mudring* 24
*For protection of switch, GFCI, or duplex receptacles
RAISED 3/4” FOR DEVICE AND WIRE PROTECTION
701F 702F 700F 701FG
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701F To protect 1 device opening / for 1 device mudring 100
702F To protect 2 device opening / for 2 device mudring 50
700F To protect round opening for fixture mudring 50
with 2-3/4” O.C. device ears
FLAT FOR WIRE PROTECTION
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701FG Gangable for RACO 686, 687, and RACO non-gangable 100
masonry boxes
FLAT FOR WIRE PROTECTION (GANGABLE)
701R X —— — —
702R —X — —
701F X —— S
702F —X — —S
700F —— X
701FG —— X —
CATALOG SINGLE TWO ROUND RACO®686 & 687 CADDY®CADDY®
NUMBER DEVICE DEVICE MUDRING & NONGANGABLE MP1STM MP2STM
MUDRING MUDRING MASONRY BOXES
S = Secondary Use
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A53
A54 rkfsbop^i=molqb`qlo=mi^qbp
o^`l=pqbbi=_lubp=
C=`lsbop
clo=ilt=sliq^db=jlrkqfkd=ofkdpL_o^`hbqp=J=a^q^
loabofkd=fkcloj^qflk=J=afjbkpflkp
701RD 702RD
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701RD To protect 1 device, for Caddy®Ring / low voltage 24
mounting bracket MP1STM*
702RD To protect 2 device, for Caddy®Ring / low voltage 24
mounting bracket MP2STM*
*For protection of control devices, cable jacks, most Decora®style inserts and similar devices
RAISED 3/4” FOR CONTROL DEVICE AND WIRE PROTECTION
701FD 702FD
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701FD To protect 1 device opening, for Caddy®Ring / low 50
voltage mounting bracket MP1STM *
702FD To protect 2 device opening, for Caddy®Ring / low 25
voltage mounting bracket MP2STM *
FLAT FOR LOW VOLTAGE WIRE PROTECTION
Applications
Eliminates drywall compound, debris,
paint, and drywall router bit from entering
box or damaging conductors or devices
Available in raised or flat versions
Raised covers all DecoraTM, duplex and
switch wiring devices
Flat close off mudring opening and pro-
tect wires from drywaller’s router bit tools
Product Features
Covers entire opening of low
voltage plate
Features patented wire retrieval loop
that allows data cable to be attached to
cover NO MORE LOST CABLES IN
THE WALL!
No hardware required for use - simply
snaps on and off standard mudring
Durable steel construction allows cover
to be used multiple times
Finger pull bail allows cover to be easily
removed from ring
Allows for multi access to work area for
multi stage jobs
Holes in cover allow for use of screws
to prevent theft and add additional
security (screws not included)
Reference Data
Patent 7,102,079 *Can also be used on most steel single gang mudrings
701FD X —— S
702FD X——S
701RD X —— S
702RD X——S
CATALOG SINGLE TWO ROUND RACO®686 & 687 CADDY®CADDY®
NUMBER DEVICE DEVICE MUDRING & NONGANGABLE MP1STM MP2STM
MUDRING MUDRING MASONRY BOXES
S = Secondary Use
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A54
o^`l=pqbbi=_lubp=
C=`lsbop
A55
loabofkd=fkcloj^qflk=J=afjbkpflkp
_lu=prmmloq=molar`qp
_o^`bp=^ka=buqbkabop
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9003 - 9006, 9012 -9015)
For metal or wood stud box postitioning
Features
Available for 1-1/2” or 2-1/8” deep boxes
Locator dimples on face of bar allows
for exact positioning of single or
multiple boxes
Dimple feature provides quick start of
screws, and reinforcement to prevent
box mounting screws from stripping
out when box is mounted
Design of adjustable brace allows
ground screw to clear when box is
mounted
Boxes attach easily with self-tapping
screws
Compliances
9003 - 9006 9012 - 9015
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9003 For 16” stud spacing, 1-1/2” deep box 50
9004 For 16” stud spacing, 2-1/8” deep box 50
9005 For 24” stud spacing, 1-1/2” deep box 50
9006 For 24” stud spacing, 2-1/8” deep box 50
NON-ADJUSTABLE BOX MOUNTING BRACE FOR 4” AND 4-11/16” SQUARE BOX
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9012 Adjusts from 10-3/8” to 18”, 1-1/2” deep box 50
9013 Adjusts from 10-3/8” to 18”, 2-1/8” deep box 50
9014 Adjusts from 15” to 26”, 1-1/2” deep box 50
9015 Adjusts from 15” to 26”, 2-1/8” deep box 50
ADJUSTABLE BOX MOUNTING BRACE FOR 4” AND 4-11/16” SQUARE BOX
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9016 To be used for 6” stud size 100
LEG EXTENDER
9016
Applications (9016)
Extension for leg to accommodate 6”
deep studs
Features
To be used with the following RACO®
SKU’s: 9001, 9002, 9009, 9010, 9011
Simple snap-on design
Compliances
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A55
A56
o^`l=pqbbi=_lubp=
C=`lsbop
_lu=prmmloq=molar`qp
_o^`hbqp
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9007, 9018)
Supports electrical boxes when
mounted to a stud
Features
Dual-point mounting ensures a secure,
stable installation
When properly mounted, the leg can-
not be bent by other trades during
the construction process
Mounts 4” or 4-11/16” sq. box to
2-1/2”, 3-1/2”, 4” and 6” studs
Box can be mounted on bracket with-
out raised cover to save time by pro-
viding maximum work area in box
When mounted, drywall ring is
brought to within 1/16” of drywall
every time and will not bulge or
break out drywall
Compliance
9007 9018
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9007 Right side stud mount 100
9018 Left or right side stud mount 100
TWO-POINT BOX MOUNTING BRACKETS
loabofkd=fkcloj^qflk=J=afjbkpflkp
loabofkd=fkcloj^qflk=J=afjbkpflkp
9001 9002
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9001 3 - box, for 16” on center studs 50
9002 4 - box, for 24” on center studs 50
FIXED POSITION BOX MOUNTING BRACKETS
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9001, 9002)
Positions electrical boxes, plaster
rings, and low voltage devices
between studs
Features
Fold-back stabilizer leg prevents brack-
et from being pushed back in wall
cavity during drywall installation
Designed for 2-1/2” or 3-1/2” studs.
Add RACO®9016 to leg to accom-
modate 6” depth studs
Mounts 4” or 4-11/16” sq. boxes
Box can be mounted on ring without
raised cover to save time by provid-
ing maximum work area inside box
When mounted, raised cover is
brought to within 1/16” of drywall
every time and will not bulge or
break out drywall
Compliances
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A56
o^`l=pqbbi=_lubp=
C=`lsbop
A57
_lu=prmmloq=molar`qp
_o^`hbqp=^ka=_lu=prmmloqp
loabofkd=fkcloj^qflk=J=afjbkpflkp
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9011)
Supports 3” x 2” switch boxes when
mounted to stud
Features
Accommodates all 3” x 2” switch boxes
with one or two screw plaster ears
Bracket can be ganged on same side
of stud allowing for increased flexibility
Bracket can be mounted on both
sides of stud for double mounting
Will not bulge or break out drywall
when mounted
Compliances
9011 9008 - 9017
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9011 For 2-1/2” or 3-1/2” metal studs 100
BOX MOUNTING BRACKET FOR 3” X 2” SWITCH BOXES
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9008 New or old work, single-gang 100
9017 New or old work, single-gang 20 bags*
LOW VOLTAGE MOUNTING BRACKET
Applications (9008, 9017)
Mounts standard low voltage wall
plates, old work (existing walls) or
new work (wood or metal studs)
Features
For use on low voltage Class 2 cir-
cuits only where electrical boxes are
not required
Can be used to mount telephone jacks,
computer outlets, security/sound sys-
tems, television antennas, etc.
Fast, precise mounting of low voltage
wall plates to walls or studs
Compliances
*2 brackets per poly-bag
9009 9010
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9009 12” tall bracket 25
9010 18” tall bracket 25
FLOOR MOUNTED BOX SUPPORT
Applications (9009, 9010)
Supports electrical boxes from floor
or concrete forms
Features
Fold-back stabilizer prevents bracket
from being pushed back in wall cavi-
ty during drywall installation
Designed for mounting sq. boxes 12”
or 18” above floor. Mounts to metal or
wood plate
Mounts 4” or 4-11/16” sq. boxes
Box can be mounted on support with-
out drywall ring to save time by pro-
viding maximum working area in box
When mounted, raised cover is
brought to within 1/16” of drywall
every time. Will not bulge or break
out drywall
Compliances
loabofkd=fkcloj^qflk=J=afjbkpflkp
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A57
A58
o^`l=pqbbi=_lubp=
C=`lsbop
*UL Rated at 16” span on center
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
980 Spring-steel bracket 50
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR
CODE CEILING FAN FIXTURE
(DYNAMIC) LBS. (STATIC) LBS.
920* 3/8" Stud, adj. 14-1/4" to 22-1/2" 50 No 50
922* Clip, adj. 14-1/4" to 22-1/2" 50 No 50
^``bpplofbp=clo=pqbbi=_lubp
loabofkd=fkcloj^qflk=J=afjbkpflkp
ADJUSTABLE BAR HANGERS
920 922
RECOMMENDED MAX.
SUPPORT LOAD
Application (920, 922)
Adjustable bar hanger allows box to be
placed between ceiling joists or wall
studs quickly and easily
Product Features
Both RACO®920 and 922 bar fixture
hangers allow box to be located any-
where along length of bar
RACO®920 includes 3/8" trade size
stud to accommodate fixture stem
922 Clip installs in 1/2" knockout locat-
ed in bottom (back) of box
RACO® box must be ordered separately
Box Installation
Bar hangers attach to octagon or square
boxes through center 1/2" knockouts
Remove the knockout
Remove the screw and fixture stud (or
clip) from bar hanger
Place the stud inside the box and
replace the screw
When box is located accurately between
the joists, tighten the screw securely
Compliance
– File E195973
BOX-LOC®Application (980)
Allows any box to be attached to either
side of a metal stud quickly and easily
BOX-LOC® Product Features
Patented spring steel design
Installs in seconds without tools
Mounts on either side of stud
Repositions easily
Bracket may be added to any RACO®4"
or 4-11/16" square steel box - simply tap
the bracket with a hammer and the
barbed hooks hold it in place
BOX-LOC®is a snap to install. Place the
bracket on the open side of the stud first.
Slots in the bracket engage the lip of the
stud and actually crimp it as you press the
bracket on the stud. Barbed hooks dig into
the flat side of the stud, locking it in place
Far Side Box Support Application (978)
Prevents installed box from “floating” in
wall cavity
Far Side Box Support Features
Snaps into hole in back of box
Easy to cut to fit depth of cavity
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
978 1-7/8" Rigid, plastic support 50
BOX-LOC®METAL STUD CLIP
FAR SIDE BOX SUPPORT
978 Installed
BOX-LOC®
980 978
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A58
o^`l=pqbbi=_lubp=
C=`lsbop
A59
^``bpplofbp=clo=pqbbi=_lubp
“Old Work Saddle” Application (970RAC)
The “Old Work Saddle” #970 is designed
to be used with 2-1/2" deep switch
boxes that have plaster ears
“Old Work Saddle” Product Feature
#970RAC installs into the 1/2" bottom
conduit knockout
GRIP-LOKTM Application (977, 8977, 8977-5)
The GRIP-LOKTM support is designed to
be used with any deep switch box that
has plaster ears
GRIP-LOKTM Product Feature
Simply slip GRIP-LOKTM between box and
wall, then bend tabs into the box
Add-A-Depth Applications (976)
Add-A-Depth ring or “goof-ring” is de-
signed to act as a barrier between combu-
stible wall surfaces and the wiring system
For single and two-gang device boxes
There is no UL standard for this product
Subject to acceptance by an electric
inspector
The NEC Code States: 314.20 in Wall or
Ceiling
In walls or ceilings of concrete, tile, or
other non-combustible material, boxes
shall be installed so that the front edge
of the box will not set back of the fin-
ished surface more than 1/4 inch
(6.35 mm). In walls and ceilings con-
structed of wood or other combustible
material, boxes shall be flush with the
finished surface or project there from
Nailing Spur Applications (2709, 2710)
Protects nonmetallic sheathed cable or
raceway type wires running through
wood members from accidental nail,
screw or drill penetration
No nails required
Compliance
– File E195973, E195968
(not 970RAC)
Applications (969)
Old work box support clips convert stan-
dard switch box to old work type
Product Feature
Old work switch box clips for use with
1/2” thick standard drywall
One pair per box
969 970RAC GRIP-LOKTM
977, 8977, 8977-5
CATALOG STD. UPC
NUMBER DESCRIPTION PKG. BAR CODE
977 Supplied as a pair. Use pair to mount switch box 100 pairs
with plaster ears in hollow wall, 1-7/8” long legs
8977 Supplied as a pair. Use pair to mount switch box 50 pairs
with plaster ears in hollow wall, 1-7/8” long legs
8977-5 Supplied as a pair. Use pair to mount switch box 100 pairs*
with plaster ears in hollow wall, 1-7/8” long legs
CATALOG DESCRIPTION FOR RACO STD. UPC BAR
NUMBER SWITCH BOXES PKG. CODE
Plaster Ears - 410, 420, 440, 445, 500, 503, 100
961 Open Style w/screws 506, 508, 526, 545, 560, 565,
567, 570RAC, 590, 600, 601
962 Plaster Ears - 150, 400, 591 100
Clipped Style w/screws
963 Plaster Ears - 471, 487, 517, 518, 519, 523 100
1 Screw Style w/screws
964 Old Work Griptite Clip 523 100
w/screws
966 Old Work Tigergrip Clip 487, 506, 517 100
w/screws
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
970RAC Mounts switch boxes with plaster 10
ears in hollow walls or ceilings
*4 Bundles of 25
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
969 Old work clips for switch box 50
SWITCH BOX SUPPORT “OLD WORK SADDLE”
SWITCH BOX ACCESSORIES
OLD WORK SWITCH BOX CLIPS
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
976 Adjustment range 1/4”-1”, Two 1-1/8” screws included 25
ADD-A-DEPTH RING EXTENDS SWITCH BOX SET TOO DEEP IN WALL
976
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
2709 Nailing spurs, 2-9/16” H. x 1-1/2” W. x 1/16” TH. 1/2” Spike 100
2710 Nailing spurs, 2-9/16” H. x 1-1/2” W. x 1/16” TH. 1/2” Spike 200
2709-9 Nailing spurs, 2-9/16” H. x 1-1/2” W. x 1/16” TH. 1/2” Spike 100
2709, 2710,
2709-9
CABLE PROTECTOR
GRIP-LOKTM “OLD WORK” SWITCH BOX SUPPORT
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A59
A60
o^`l=pqbbi=_lubp=
C=`lsbop
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR
CODE
998 4-Way combo head green dye finish 3/8” ground screw for 1000
10-32 tapped hole, clam shell package (100 pcs per clam shell
8998-1 4-Way combo head green dye finish 3/8”ground screw for 50
10-32 tapped hole, poly bag (10 pcs. per bag) bags*
973 Slotted head green dye finish 3/8”ground screw for 10-32 1000
tapped hole, clam shell package (100 pcs per clam shell )
8973-1 Slotted head green dye finish 3/8”ground screw for 10-32 50
tapped hole, poly bag (10 pcs. per bag) bags*
975 Green dye finish ground clip for #14-#10 AWG copper, 1000
clam shell package (100 pcs per clam shell)
8975-1 Green dye finish ground clip for #14-#10 AWG copper, 50
poly bag (10 pcs. per bag) bags*
^``bpplofbp=clo=pqbbi=_lubp
loabofkd=fkcloj^qflk=J=afjbkpflkp
Grounding Applications
Grounding accessories provide a safe
electrical path to ground to help pre-
vent shock
Grounding screws thread into the box
and provide a means of fastening the
ground conductor
Ground wires fasten to the box and are
then connected to wiring system or
wiring device
RACO®6" and 8" ground pigtails fea-
ture 4-way (slotted, phillips, hex-head)
combo 10-32 captive screw
Ground clips provide a quick method of
fastening a ground conductor to the
edge of a steel outlet box
Ground clips are designed for use with
solid No. 14, 12, and 10 gauge copper
conductor or No. 12 and 10 gauge
aluminum conductor
Only one solid ground wire to be in-
stalled per ground clip
Compliance
– File E195975 (975, 8975-1)
982, 994 #14 WIRE
996, 8996-1, 8983-1,
983 #12 WIRE
992 #14 WIRE
993 #12 WIRE
973,
8973-1
998,
8998-1
975,
8975-1
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR
WIRE LENGTH CODE
6" 8"
982 994 #14 Solid insulated copper wire, captive 4-way combo 1000
head green dye finish ground screw one end (25 pc. bundles)
983 996 #12 Solid insulated copper wire, captive 4-way combo 1000
head green dye finish ground screw one end (25 pc. bundles)
8983-1 8996-1 #12 Solid insulated copper wire, captive 4-way combo head 40
green dye finish ground screw one end, poly bag bags*
(10 pcs per poly bag)
984 997 #14 Solid bare copper wire, captive 4-way combo head 1000
green dye finish ground screw one end (25 pc. bundles)
992 #14 Stranded insulated copper wire, captive 4-way 500
combo head green dye finish ground screw one end,
spade terminal one end (100 pc. bundles)
993 #12 Stranded insulated copper wire, captive 4-way 500
combo head green dye finish ground screw one end,
spade terminal one end (100 pc. bundles)
984, 997
#14 WIRE
*Order standard package bag quantities only, not per piece
GROUNDING PIGTAILS
GROUNDING SCREWS AND CLIPS
4714
THE INSIDER®
4714, THE INSIDER® will secure nonmetallic sheathed cable in 1/2” KO (See pg. B87)
03 Pg A49-A60.qxp 6/9/2008 9:10 AM Page A60
Page 1 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 2 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 3 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 4 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 5 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 6 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 7 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 8 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 9 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 10 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 11 of 12 - 03 Pg A49-A60.qxp  111090-Catalog
Page 12 of 12 - 03 Pg A49-A60.qxp  111090-Catalog

Navigation menu