CATALOG NO. KNOCKOUTS CU. STD. UPC
NUMBER OF TOP &* SIDES* BACK IN. PKG. BAR
GANGS B0TT0M CODE
941 2 4-3/4", 4-conc. 4-conc. 3-1/2", 2-3/4" 70.0 5
942 3 8-3/4", 2-conc. 4-conc. 6-1/2", 4-3/4" 90.0 5
943 4 4-3/4", 4-conc. 4-conc. 6-1/2", 4-3/4" 110.0 5
944 5 6-3/4", 4-conc. 4-conc. 6-1/2", 4-3/4" 130.0 5
945 6 6-3/4", 6-conc. 4-conc. 6-1/2", 4-3/4" 150.0 1
951 2 8-conc. 4-conc. 3-1/2", 2-3/4" 47.0 5 —
952 3 10-conc. 4-conc. 6-1/2", 4-3/4" 60.0 5
953 4 12-conc. 4-conc. 6-1/2", 4-3/4" 72.8 5
954 5 14-conc. 4-conc. 6-1/2", 4-3/4" 85.8 5 —
955 6 16-conc. 4-conc. 6-1/2", 4-3/4" 98.5 1 —
956 7 18-conc. 4-conc. 6-1/2", 4-3/4" 111.5 1 —
957 8 20-conc. 4-conc. 6-1/2", 4-3/4" 124.5 1 —
958 9 22-conc. 4-conc. 6-1/2", 4-3/4" 137.3 1 —
Application
•Gang boxes are used where a num-
ber of wiring devices are to be
centrally located
Product Features
•Gang boxes save time in installation,
no need to gang boxes together
•Have 1/2" and 3/4" concentric
KO’s for use with a wide variety of
wiring methods
•Bottom KO pattern, 3-1/2" and 2-3/4"
at either end of box
•Accept two styles of covers, flat and
3/4" raised device cover
•Device covers also fit next smaller
box, i.e. three-gang cover fits two or
three-gang box
•Use low voltage partitions
#974 or #949
941 through 945
*1-5/8" deep boxes, concentric KO’s are 1/2" & 3/4" *2-1/2" deep boxes, concentric KO’s are 3/4" & 1"
CATALOG NO. OF A B C
NUMBER GANGS
941 2 2-1/2" 6-3/8" 6-13/16"
942 3 2-1/2" 8-3/16" 8-5/8"
943 4 2-1/2" 10" 10-7/16"
944 5 2-1/2" 11-13/16" 12-1/4"
945 6 2-1/2" 13-5/8" 14-1/16"
951 2 1-5/8" 6-3/8" 6-13/16"
952 3 1-5/8" 8-3/16" 8-5/8"
953 4 1-5/8" 10" 10-7/16"
954 5 1-5/8" 11-13/16" 12-1/4"
955 6 1-5/8" 13-5/8" 14-1/16"
956 7 1-5/8" 15-7/16" 15-7/8"
957 8 1-5/8" 17-1/4" 17-11/16"
958 9 1-5/8" 19-1/16" 19-1/2"
STEEL GANG BOXES
d^kd=_lubp
o^`l=pqbbi=_lubp=
C=`lsbop
A49
NJRLUÒ=^ka=OJNLOÒ=abbm
loabofkd=fkcloj^qflk=J=afjbkpflkp
951 through 958
GANG BOXES – 1-5/8" & 2-1/2” DEEP – WELDED
WITH CONDUIT KO’S
DIMENSIONS
Compliance
•– File E195978
4714, THE INSIDER® will secure nonmetallic sheathed cable in 1/2” KO (See pg. B87)
03 Pg A49-A60.qxp 6/9/2008 9:07 AM Page A49
A50 `lsbop=^ka=m^oqfqflkp
o^`l=pqbbi=_lubp=
C=`lsbop
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG NO. OF WIDTH CU. IN. STD. UPC
NUMBER GANGS PKG. BAR CODE
821 2 7-1/16" 10.0 5 —
822 3 8-7/8" 15.3 5
823 4 10-11/16" 20.3 5
824 5 12-1/2" 25.5 5 —
825 6 14-5/16" 30.5 1 —
826 7 16-1/8" 35.5 1 —
827 8 17-15/16" 40.8 1 —
828 9 19-3/4" 45.8 1 —
CATALOG STD. UPC
NUMBER DESCRIPTION PKG. BAR CODE
974 For 1-5/8” Deep 25 —
949 For 2-1/2” Deep 25 —
Application
•Gang box covers permit the mounting
of devices
Product Feature
•Device covers also fit next smaller
box, i.e. three gang cover fits two or
three gang box
Compliance
•ÓFile E195978 (Cat. #974
and 949 not UL Listed)
823 974
LOW VOLTAGE PARTITION FOR GANG BOXES
DEVICE COVERS FOR GANG BOXES RAISED 3/4"
846
CATALOG NO. OF WIDTH CU. IN. STD. UPC
NUMBER GANGS PKG. BAR CODE
844 2 7-1/16" — 5 —
845 38-7/8" —5—
846 4 10-11/16" — 5 —
847 512-1/2" —1—
848 6 14-5/16" — 1 —
849 716-1/8" —1—
850 8 17-15/16" — 1 —
851 9 19-3/4" — 1 —
FLAT, BLANK COVERS FOR GANG BOXES
949
03 Pg A49-A60.qxp 6/9/2008 9:07 AM Page A50
pqbbi=`lk`obqb=ofkdp
o^`l=pqbbi=_lubp=
C=`lsbop
A51
KNOCKOUT SIZE A B
1/2” and 3/4” KOs 1/2” 3/4”
3/4” and 1” KOs 3/4” 1”
CATALOG DESCRIPTION CU. STD. UPC BAR
NUMBER IN. PKG. CODE
280 3/8” x 1/2” Long stud, 8-1/2”, 8-3/4” KO’s* 43.0 20 —
918 30” Long bars for hung ceiling box — 40 —
CATALOG DEPTH KO NO. CU. STD. UPC
NUMBER SIZES ROWS IN. PKG. BAR
KO’S CODE CEILING FAN FIXTURE
(DYNAMIC) LBS. (STATIC) LBS.
270RAC 2” 1/2” & 3/4” Single 24.5 25 — No 50
271 2-1/2” 1/2” & 3/4” Single 30.8 25 — No 50
272 3” 1/2” & 3/4” Single 37.0 25 — No 50
277 3” 3/4” & 1” Single 37.0 25 — No 50
273 3-1/2” 1/2” & 3/4” Double 43.0 20 — No 50
278 3-1/2” 3/4” & 1” Single 43.0 20 — No 50
274 4” 1/2” & 3/4” Double 49.3 20 — No 50
279 4” 3/4” & 1” Double 49.3 20 — No 50
275 5” 1/2” & 3/4” Double 61.5 10 — No 50
276 6” 1/2” & 3/4” Double 74.0 10 — No 50
284* 4” 1/2” & 3/4” Double 49.3 6 — 35 75
Applications
•Concrete rings are used with poured
deck (floor) in high-rise construction
•These boxes are installed on wooden
or steel concrete forms. After the
forms are removed, the box is flush
with the concrete
•RACO®Ceiling Fan Concrete Ring 284
is listed for support of ceiling fans
Product Features
•Flat sides provide excellent contact
for locknuts
•External ears are used to nail the ring
to the wood form
•The top cover is removable for
before-pour work
•Ears on inside of box are for fixtures
•Waxed fixture ears prevent concrete
from interfering with the threads
•Variety of cover plates are available
•Cover plate must be ordered sepa-
rately with all (except 280 which
includes a 891 cover) RACO®
concrete rings
KNOCKOUT LOCATIONS
HUNG CEILING BOX – 3-1/2" DEEP
*Order bars separately
890 891 893892
CATALOG DESCRIPTION KNOCKOUTS O.D. STD. UPC
NUMBER DIAM. PKG. BAR CODE
890 — 3-1/2”, 2-3/4” 4-1/2” 25 —
891 3/8” Stud 2-1/2”, 2-3/4” 4-1/2” 25 —
892 Flat, blank — 4-1/2” 25 —
893 Joins Oct. Ext. ring to concrete ring — 4-1/2” 50 —
Includes two retained screws
*280 shown with 918 BARS
284 GORILLA-RING™
270RAC, 271, 272, 273, 274,
275, 276, 277, 278, 279
STEEL CONCRETE RINGS
loabofkd=fkcloj^qflk=J=afjbkpflkp
RECOMMENDED MAX.
SUPPORT LOAD
CONCRETE RINGS
CONCRETE RING – BACK PLATES/COVERS AND ADAPTER RING
Compliance
•– File E195978
*Ceiling Fan Support Box
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A51
A52 j^plkov=_lubp=^ka=m^oqfqflkp
o^`l=pqbbi=_lubp=
C=`lsbop
OJNLOÒ=^ka=PJNLOÒ=abbm
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG NO. OF WIDTH KNOCKOUTS CU. STD. UPC BAR
NUMBER GANGS (B) ENDS BOTTOM SIDES IN. PKG. CODE
690 1 1-31/32" 2 conc. 2 conc. 4 conc. 16.0 25 —
691 2 3-25/32" 4 conc. 4 conc. 4 conc. 31.8 25 —
692 3 5-19/32" 6 conc. 3 conc. 4 conc. 47.8 10 —
693 4 7-13/32" 8 conc. 4 conc. 4 conc. 63.5 10 —
694 5 9-7/32" 10 conc. 5 conc. 4 conc. 79.5 10 —
960 6 11-1/32" 12 conc. 6 conc. 4 conc. 95.3 1 —
Applications
•Masonry boxes are designed to accom-
modate the mounting of switches or
other devices in masonry walls
•Gangable masonry boxes offer the
option of constructing a box to hold two
or more devices
•2-1/2" deep boxes are used in 4” block
walls, 3-1/2” deep boxes are used in 6”
or 8” block walls
Non-Gangable Product Features
•Rugged welded construction does not
fall apart during construction
•Available from one to six gang configu-
rations in both 2-1/2" and 3-1/2" depths
•Rectangular shape fits square cuts in
block
•Large volume design allows for addi-
tional work room inside the box
•Standard 1/2” and 3/4” concentric
knockouts
•Device ears are formed inside the box,
preventing mortar from getting in the
device holes
•Steel low voltage partition: 971 fits all
2-1/2” or 3-1/2” depths (non-gangable
versions only)
•Standard wall plates cover the box
Gangable Product Features
•Rugged design does not fall apart dur-
ing construction
•Gangable design allows installer to build
unlimited number of gangs to hold mul-
tiple devices
•Rectangular shape fits square cuts in block
•Standard 1/2”- 3/4” TKO®knockouts
•Device ears are formed inside the box,
preventing mortar from getting in the
device holes
•Steel low voltage partitions: 675 fits 2-
1/2” deep box, 676 fits 3-1/2” deep box
•Forward mounted grounding provision
allows for easy installation of ground-
ing pigtail
•Standard wall plates cover the box
Compliance
•– File E195978 (Cat. #971
not UL Listed) STEEL MASONRY
BOXES 691, 696
690 691 692
971
696
697
695, 8695
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
FOR NON-GANGABLE MASONRY BOXES
971 For 2-1/2" or 3-1/2" deep boxes 25
FOR GANGABLE MASONRY BOXES
675 For 2-1/2" deep boxes 20
676 For 3-1/2" deep boxes 20
CATALOG NO. OF WIDTH KNOCKOUTS CU. STD. UPC BAR
NUMBER GANGS (B) ENDS BOTTOM SIDES IN. PKG. CODE
695 1 1-31/32" 4 conc. 2 conc. 4 conc. 22.5 25 —
8695 1 1-31/32" 4 conc. 2 conc. 4 conc. 22.5 25
696 2 3-25/3 2" 8 conc. 4 conc. 4 conc. 45.0 25
697 3 5-19/3 2" 12 conc. 3 conc. 4 conc. 67.3 10
698 4 7-13/3 2" 16 conc. 4 conc. 4 conc. 89.8 10 —
699 5 9-7/3 2" 20 conc. 5 conc. 4 conc. 112.3 10 —
965 6 11-1/3 2" 24 conc. 6 conc. 4 conc. 134.8 1 —
LOW VOLTAGE PARTITION FOR MASONRY BOXES
MASONRY BOXES – 2-1/2" DEEP – NONGANGABLE WITH CONDUIT KO’S
MASONRY BOXES – 3-1/2" DEEP – NONGANGABLE WITH CONDUIT KO’S
675, 676 688, 689
CATALOG NO. OF DEPTH WIDTH KNOCKOUTS CU. STD. UPC BAR
NUMBER GANGS (B) ENDS BOTTOM SIDES IN. PKG. CODE
688 1 2-1/2” 1-15/16” 2 TKO®2 TKO®4 TKO®15.5 20
689 1 3-1/2” 1-15/16” 4 TKO®. 2 TKO®4 TKO®22.5 20
MASONRY BOXES – GANGABLE WITH CONDUIT KO’S
4714, THE INSIDER® will secure nonmetallic sheathed cable in 1/2” KO (See pg. B87)
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A52
rkfsbop^i=molqb`qlo=mi^qbp
o^`l=pqbbi=_lubp=
C=`lsbop
A53
clo=rpb=tfqe=jraofkdp=J=mltbo
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications
•Eliminates drywall compound, debris,
paint, and drywall router bit from entering
box or damaging conductors or devices
•Available in raised or flat versions —
Raised covers all DecoraTM, duplex and
switch wiring devices
Flat close off mudring opening and pro-
tect wires from drywaller’s router bit tools
Product Features
•Covers entire opening of mudring
•No hardware required for use - simply
snaps on and off standard mudring
•Durable steel construction allows cover
to be used multiple times
•Holes in cover allow for use of screws
to prevent theft and add additional
security (screws not included)
•Recessed tab allows cover to be easily
removed using pliers, side cutters or
flat screw driver
Reference Data
•Patent 7,102,079
701R 702R
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701R To protect 1 device / for 1 device mudring* 24 —
702R To protect 2 devices / for 2 device mudring* 24 —
*For protection of switch, GFCI, or duplex receptacles
RAISED 3/4” FOR DEVICE AND WIRE PROTECTION
701F 702F 700F 701FG
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701F To protect 1 device opening / for 1 device mudring 100 —
702F To protect 2 device opening / for 2 device mudring 50 —
700F To protect round opening for fixture mudring 50 —
with 2-3/4” O.C. device ears
FLAT FOR WIRE PROTECTION
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701FG Gangable for RACO 686, 687, and RACO non-gangable 100 —
masonry boxes
FLAT FOR WIRE PROTECTION (GANGABLE)
701R X —— — ——
702R —X— — ——
701F X —— — S—
702F —X— — —S
700F —— X — ——
701FG ——— X ——
CATALOG SINGLE TWO ROUND RACO®686 & 687 CADDY®CADDY®
NUMBER DEVICE DEVICE MUDRING & NONGANGABLE MP1STM MP2STM
MUDRING MUDRING MASONRY BOXES
S = Secondary Use
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A53
A54 rkfsbop^i=molqb`qlo=mi^qbp
o^`l=pqbbi=_lubp=
C=`lsbop
clo=ilt=sliq^db=jlrkqfkd=ofkdpL_o^`hbqp=J=a^q^
loabofkd=fkcloj^qflk=J=afjbkpflkp
701RD 702RD
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701RD To protect 1 device, for Caddy®Ring / low voltage 24 —
mounting bracket MP1STM*
702RD To protect 2 device, for Caddy®Ring / low voltage 24 —
mounting bracket MP2STM*
*For protection of control devices, cable jacks, most Decora®style inserts and similar devices
RAISED 3/4” FOR CONTROL DEVICE AND WIRE PROTECTION
701FD 702FD
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
701FD To protect 1 device opening, for Caddy®Ring / low 50 —
voltage mounting bracket MP1STM *
702FD To protect 2 device opening, for Caddy®Ring / low 25 —
voltage mounting bracket MP2STM *
FLAT FOR LOW VOLTAGE WIRE PROTECTION
Applications
•Eliminates drywall compound, debris,
paint, and drywall router bit from entering
box or damaging conductors or devices
•Available in raised or flat versions —
Raised covers all DecoraTM, duplex and
switch wiring devices
Flat close off mudring opening and pro-
tect wires from drywaller’s router bit tools
Product Features
•Covers entire opening of low
voltage plate
•Features patented wire retrieval loop
that allows data cable to be attached to
cover —NO MORE LOST CABLES IN
THE WALL!
•No hardware required for use - simply
snaps on and off standard mudring
•Durable steel construction allows cover
to be used multiple times
•Finger pull bail allows cover to be easily
removed from ring
•Allows for multi access to work area for
multi stage jobs
•Holes in cover allow for use of screws
to prevent theft and add additional
security (screws not included)
Reference Data
•Patent 7,102,079 *Can also be used on most steel single gang mudrings
701FD X —— — S—
702FD —X———S
701RD X —— — S—
702RD —X———S
CATALOG SINGLE TWO ROUND RACO®686 & 687 CADDY®CADDY®
NUMBER DEVICE DEVICE MUDRING & NONGANGABLE MP1STM MP2STM
MUDRING MUDRING MASONRY BOXES
S = Secondary Use
03 Pg A49-A60.qxp 6/9/2008 9:08 AM Page A54
o^`l=pqbbi=_lubp=
C=`lsbop
A55
loabofkd=fkcloj^qflk=J=afjbkpflkp
_lu=prmmloq=molar`qp
_o^`bp=^ka=buqbkabop
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9003 - 9006, 9012 -9015)
•For metal or wood stud box postitioning
Features
•Available for 1-1/2” or 2-1/8” deep boxes
•Locator dimples on face of bar allows
for exact positioning of single or
multiple boxes
•Dimple feature provides quick start of
screws, and reinforcement to prevent
box mounting screws from stripping
out when box is mounted
•Design of adjustable brace allows
ground screw to clear when box is
mounted
•Boxes attach easily with self-tapping
screws
Compliances
•
9003 - 9006 9012 - 9015
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9003 For 16” stud spacing, 1-1/2” deep box 50 —
9004 For 16” stud spacing, 2-1/8” deep box 50 —
9005 For 24” stud spacing, 1-1/2” deep box 50 —
9006 For 24” stud spacing, 2-1/8” deep box 50 —
NON-ADJUSTABLE BOX MOUNTING BRACE FOR 4” AND 4-11/16” SQUARE BOX
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9012 Adjusts from 10-3/8” to 18”, 1-1/2” deep box 50 —
9013 Adjusts from 10-3/8” to 18”, 2-1/8” deep box 50 —
9014 Adjusts from 15” to 26”, 1-1/2” deep box 50 —
9015 Adjusts from 15” to 26”, 2-1/8” deep box 50 —
ADJUSTABLE BOX MOUNTING BRACE FOR 4” AND 4-11/16” SQUARE BOX
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9016 To be used for 6” stud size 100 —
LEG EXTENDER
9016
Applications (9016)
•Extension for leg to accommodate 6”
deep studs
Features
•To be used with the following RACO®
SKU’s: 9001, 9002, 9009, 9010, 9011
•Simple snap-on design
Compliances
•
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A55
A56
o^`l=pqbbi=_lubp=
C=`lsbop
_lu=prmmloq=molar`qp
_o^`hbqp
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9007, 9018)
•Supports electrical boxes when
mounted to a stud
Features
•Dual-point mounting ensures a secure,
stable installation
•When properly mounted, the leg can-
not be bent by other trades during
the construction process
•Mounts 4” or 4-11/16” sq. box to
2-1/2”, 3-1/2”, 4” and 6” studs
•Box can be mounted on bracket with-
out raised cover to save time by pro-
viding maximum work area in box
•When mounted, drywall ring is
brought to within 1/16” of drywall
every time and will not bulge or
break out drywall
Compliance
•
9007 9018
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9007 Right side stud mount 100 —
9018 Left or right side stud mount 100 —
TWO-POINT BOX MOUNTING BRACKETS
loabofkd=fkcloj^qflk=J=afjbkpflkp
loabofkd=fkcloj^qflk=J=afjbkpflkp
9001 9002
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9001 3 - box, for 16” on center studs 50 —
9002 4 - box, for 24” on center studs 50 —
FIXED POSITION BOX MOUNTING BRACKETS
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9001, 9002)
•Positions electrical boxes, plaster
rings, and low voltage devices
between studs
Features
•Fold-back stabilizer leg prevents brack-
et from being pushed back in wall
cavity during drywall installation
•Designed for 2-1/2” or 3-1/2” studs.
Add RACO®9016 to leg to accom-
modate 6” depth studs
•Mounts 4” or 4-11/16” sq. boxes
•Box can be mounted on ring without
raised cover to save time by provid-
ing maximum work area inside box
•When mounted, raised cover is
brought to within 1/16” of drywall
every time and will not bulge or
break out drywall
Compliances
•
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A56
o^`l=pqbbi=_lubp=
C=`lsbop
A57
_lu=prmmloq=molar`qp
_o^`hbqp=^ka=_lu=prmmloqp
loabofkd=fkcloj^qflk=J=afjbkpflkp
loabofkd=fkcloj^qflk=J=afjbkpflkp
Applications (9011)
•Supports 3” x 2” switch boxes when
mounted to stud
Features
•Accommodates all 3” x 2” switch boxes
with one or two screw plaster ears
•Bracket can be ganged on same side
of stud allowing for increased flexibility
•Bracket can be mounted on both
sides of stud for double mounting
•Will not bulge or break out drywall
when mounted
Compliances
•
9011 9008 - 9017
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9011 For 2-1/2” or 3-1/2” metal studs 100 —
BOX MOUNTING BRACKET FOR 3” X 2” SWITCH BOXES
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9008 New or old work, single-gang 100 —
9017 New or old work, single-gang 20 bags*
LOW VOLTAGE MOUNTING BRACKET
Applications (9008, 9017)
•Mounts standard low voltage wall
plates, old work (existing walls) or
new work (wood or metal studs)
Features
•For use on low voltage Class 2 cir-
cuits only where electrical boxes are
not required
•Can be used to mount telephone jacks,
computer outlets, security/sound sys-
tems, television antennas, etc.
•Fast, precise mounting of low voltage
wall plates to walls or studs
Compliances
•
*2 brackets per poly-bag
9009 9010
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
9009 12” tall bracket 25 —
9010 18” tall bracket 25 —
FLOOR MOUNTED BOX SUPPORT
Applications (9009, 9010)
•Supports electrical boxes from floor
or concrete forms
Features
•Fold-back stabilizer prevents bracket
from being pushed back in wall cavi-
ty during drywall installation
•Designed for mounting sq. boxes 12”
or 18” above floor. Mounts to metal or
wood plate
•Mounts 4” or 4-11/16” sq. boxes
•Box can be mounted on support with-
out drywall ring to save time by pro-
viding maximum working area in box
•When mounted, raised cover is
brought to within 1/16” of drywall
every time. Will not bulge or break
out drywall
Compliances
•
loabofkd=fkcloj^qflk=J=afjbkpflkp
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A57
A58
o^`l=pqbbi=_lubp=
C=`lsbop
*UL Rated at 16” span on center
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
980 Spring-steel bracket 50
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR
CODE CEILING FAN FIXTURE
(DYNAMIC) LBS. (STATIC) LBS.
920* 3/8" Stud, adj. 14-1/4" to 22-1/2" 50 No 50
922* Clip, adj. 14-1/4" to 22-1/2" 50 No 50
^``bpplofbp=clo=pqbbi=_lubp
loabofkd=fkcloj^qflk=J=afjbkpflkp
ADJUSTABLE BAR HANGERS
920 922
RECOMMENDED MAX.
SUPPORT LOAD
Application (920, 922)
•Adjustable bar hanger allows box to be
placed between ceiling joists or wall
studs quickly and easily
Product Features
•Both RACO®920 and 922 bar fixture
hangers allow box to be located any-
where along length of bar
•RACO®920 includes 3/8" trade size
stud to accommodate fixture stem
•922 Clip installs in 1/2" knockout locat-
ed in bottom (back) of box
•RACO® box must be ordered separately
Box Installation
•Bar hangers attach to octagon or square
boxes through center 1/2" knockouts
•Remove the knockout
•Remove the screw and fixture stud (or
clip) from bar hanger
•Place the stud inside the box and
replace the screw
•When box is located accurately between
the joists, tighten the screw securely
Compliance
•– File E195973
BOX-LOC®Application (980)
•Allows any box to be attached to either
side of a metal stud quickly and easily
BOX-LOC® Product Features
•Patented spring steel design
•Installs in seconds without tools
•Mounts on either side of stud
•Repositions easily
•Bracket may be added to any RACO®4"
or 4-11/16" square steel box - simply tap
the bracket with a hammer and the
barbed hooks hold it in place
•BOX-LOC®is a snap to install. Place the
bracket on the open side of the stud first.
Slots in the bracket engage the lip of the
stud and actually crimp it as you press the
bracket on the stud. Barbed hooks dig into
the flat side of the stud, locking it in place
Far Side Box Support Application (978)
•Prevents installed box from “floating” in
wall cavity
Far Side Box Support Features
•Snaps into hole in back of box
•Easy to cut to fit depth of cavity
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
978 1-7/8" Rigid, plastic support 50 —
BOX-LOC®METAL STUD CLIP
FAR SIDE BOX SUPPORT
978 Installed
BOX-LOC®
980 978
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A58
o^`l=pqbbi=_lubp=
C=`lsbop
A59
^``bpplofbp=clo=pqbbi=_lubp
“Old Work Saddle” Application (970RAC)
•The “Old Work Saddle” #970 is designed
to be used with 2-1/2" deep switch
boxes that have plaster ears
“Old Work Saddle” Product Feature
•#970RAC installs into the 1/2" bottom
conduit knockout
GRIP-LOKTM Application (977, 8977, 8977-5)
•The GRIP-LOKTM support is designed to
be used with any deep switch box that
has plaster ears
GRIP-LOKTM Product Feature
•Simply slip GRIP-LOKTM between box and
wall, then bend tabs into the box
Add-A-Depth Applications (976)
•Add-A-Depth ring or “goof-ring” is de-
signed to act as a barrier between combu-
stible wall surfaces and the wiring system
•For single and two-gang device boxes
•There is no UL standard for this product
•Subject to acceptance by an electric
inspector
The NEC Code States: 314.20 in Wall or
Ceiling
•In walls or ceilings of concrete, tile, or
other non-combustible material, boxes
shall be installed so that the front edge
of the box will not set back of the fin-
ished surface more than 1/4 inch
(6.35 mm). In walls and ceilings con-
structed of wood or other combustible
material, boxes shall be flush with the
finished surface or project there from
Nailing Spur Applications (2709, 2710)
•Protects nonmetallic sheathed cable or
raceway type wires running through
wood members from accidental nail,
screw or drill penetration
•No nails required
Compliance
•– File E195973, E195968
(not 970RAC)
Applications (969)
•Old work box support clips convert stan-
dard switch box to old work type
Product Feature
•Old work switch box clips for use with
1/2” thick standard drywall
•One pair per box
969 970RAC GRIP-LOKTM
977, 8977, 8977-5
CATALOG STD. UPC
NUMBER DESCRIPTION PKG. BAR CODE
977 Supplied as a pair. Use pair to mount switch box 100 pairs —
with plaster ears in hollow wall, 1-7/8” long legs
8977 Supplied as a pair. Use pair to mount switch box 50 pairs
with plaster ears in hollow wall, 1-7/8” long legs
8977-5 Supplied as a pair. Use pair to mount switch box 100 pairs*
with plaster ears in hollow wall, 1-7/8” long legs
CATALOG DESCRIPTION FOR RACO STD. UPC BAR
NUMBER SWITCH BOXES PKG. CODE
Plaster Ears - 410, 420, 440, 445, 500, 503, 100
961 Open Style w/screws 506, 508, 526, 545, 560, 565,
567, 570RAC, 590, 600, 601
962 Plaster Ears - 150, 400, 591 100
Clipped Style w/screws
963 Plaster Ears - 471, 487, 517, 518, 519, 523 100
1 Screw Style w/screws
964 Old Work Griptite Clip 523 100
w/screws
966 Old Work Tigergrip Clip 487, 506, 517 100
w/screws
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
970RAC Mounts switch boxes with plaster 10
ears in hollow walls or ceilings
*4 Bundles of 25
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
969 Old work clips for switch box 50
SWITCH BOX SUPPORT “OLD WORK SADDLE”
SWITCH BOX ACCESSORIES
OLD WORK SWITCH BOX CLIPS
loabofkd=fkcloj^qflk=J=afjbkpflkp
CATALOG DESCRIPTION STD. UPC BAR
NUMBER PKG. CODE
976 Adjustment range 1/4”-1”, Two 1-1/8” screws included 25
ADD-A-DEPTH RING EXTENDS SWITCH BOX SET TOO DEEP IN WALL
976
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR CODE
2709 Nailing spurs, 2-9/16” H. x 1-1/2” W. x 1/16” TH. 1/2” Spike 100
2710 Nailing spurs, 2-9/16” H. x 1-1/2” W. x 1/16” TH. 1/2” Spike 200 —
2709-9 Nailing spurs, 2-9/16” H. x 1-1/2” W. x 1/16” TH. 1/2” Spike 100 —
2709, 2710,
2709-9
CABLE PROTECTOR
GRIP-LOKTM “OLD WORK” SWITCH BOX SUPPORT
03 Pg A49-A60.qxp 6/9/2008 9:09 AM Page A59
A60
o^`l=pqbbi=_lubp=
C=`lsbop
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR
CODE
998 4-Way combo head green dye finish 3/8” ground screw for 1000
10-32 tapped hole, clam shell package (100 pcs per clam shell
8998-1 4-Way combo head green dye finish 3/8”ground screw for 50
10-32 tapped hole, poly bag (10 pcs. per bag) bags*
973 Slotted head green dye finish 3/8”ground screw for 10-32 1000
tapped hole, clam shell package (100 pcs per clam shell )
8973-1 Slotted head green dye finish 3/8”ground screw for 10-32 50
tapped hole, poly bag (10 pcs. per bag) bags*
975 Green dye finish ground clip for #14-#10 AWG copper, 1000
clam shell package (100 pcs per clam shell)
8975-1 Green dye finish ground clip for #14-#10 AWG copper, 50
poly bag (10 pcs. per bag) bags*
^``bpplofbp=clo=pqbbi=_lubp
loabofkd=fkcloj^qflk=J=afjbkpflkp
Grounding Applications
•Grounding accessories provide a safe
electrical path to ground to help pre-
vent shock
•Grounding screws thread into the box
and provide a means of fastening the
ground conductor
•Ground wires fasten to the box and are
then connected to wiring system or
wiring device
•RACO®6" and 8" ground pigtails fea-
ture 4-way (slotted, phillips, hex-head)
combo 10-32 captive screw
•Ground clips provide a quick method of
fastening a ground conductor to the
edge of a steel outlet box
•Ground clips are designed for use with
solid No. 14, 12, and 10 gauge copper
conductor or No. 12 and 10 gauge
aluminum conductor
•Only one solid ground wire to be in-
stalled per ground clip
Compliance
•– File E195975 (975, 8975-1)
982, 994 #14 WIRE
996, 8996-1, 8983-1,
983 #12 WIRE
992 #14 WIRE
993 #12 WIRE
973,
8973-1
998,
8998-1
975,
8975-1
CATALOG DESCRIPTION STD. UPC
NUMBER PKG. BAR
WIRE LENGTH CODE
6" 8"
982 994 #14 Solid insulated copper wire, captive 4-way combo 1000 —
head green dye finish ground screw one end (25 pc. bundles)
983 996 #12 Solid insulated copper wire, captive 4-way combo 1000 —
head green dye finish ground screw one end (25 pc. bundles)
8983-1 8996-1 #12 Solid insulated copper wire, captive 4-way combo head 40
green dye finish ground screw one end, poly bag bags*
(10 pcs per poly bag)
984 997 #14 Solid bare copper wire, captive 4-way combo head 1000 —
green dye finish ground screw one end (25 pc. bundles)
—992 #14 Stranded insulated copper wire, captive 4-way 500 —
combo head green dye finish ground screw one end,
spade terminal one end (100 pc. bundles)
—993 #12 Stranded insulated copper wire, captive 4-way 500 —
combo head green dye finish ground screw one end,
spade terminal one end (100 pc. bundles)
984, 997
#14 WIRE
*Order standard package bag quantities only, not per piece
GROUNDING PIGTAILS
GROUNDING SCREWS AND CLIPS
4714
THE INSIDER®
4714, THE INSIDER® will secure nonmetallic sheathed cable in 1/2” KO (See pg. B87)
03 Pg A49-A60.qxp 6/9/2008 9:10 AM Page A60