Volume 5 Tab 1 111234 Catalog

128140-Attachment 128140-Attachment 128140-Attachment Batch9 unilog cesco-content

2014-10-22

: Pdf 111234-Catalog 111234-Catalog Batch9 unilog

Open the PDF directly: View PDF PDF.
Page Count: 251

DownloadVolume 5 Tab 1  111234-Catalog
Open PDF In BrowserView PDF
Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
IEC Contactors and Starters

1.1

XT IEC Power Control
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . . . . . . . . . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-2
V5-T1-3
V5-T1-18
V5-T1-35
V5-T1-128
V5-T1-141
V5-T1-157
V5-T1-193
V5-T1-216
V5-T1-229

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-1

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Contents

XT IEC Power Control

Description

1

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Product Overview
The XT line of IEC power
control offers starting and
protection solutions ideal for
control panels.
Innovations in the design and
development allow users to
reduce material costs, reduce
installation effort, and
enhance panel safety and
performance all in a compact
design. Some of these key
innovations include:
●

●
●

●

1
●

1
1
1

●

●

Toolless assembly of
manual motor controllers
and reversing contactors
Low coil consumption
Front accessibility to coil
terminations
Built-in surge suppression
on electronic coils
Built-in auxiliary contact for
contactors up to 32A in a
45 mm frame
Finger-safe and back-ofhand proof ratings
Direct PLC control on
185A–2000A contactors

The XT line includes a large
offering of power control
components and accessories
that cover a broad range of
applications and ratings:
●

●

●

●
●
●

●

●

●

Three-pole contactors to
2000A
Four-pole contactors to
200A
Capacitor contactors to
680 kVar
Mini contactors to 9A
Relays to 16A
Thermal overload relays to
630A
Electronic overload relays
to 1500A
Manual motor protectors
to 65A
Manual motor controllers
and combination motor
controllers to 65A

1
1
1
1
1
1
V5-T1-2

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Page
V5-T1-3
V5-T1-18
V5-T1-35
V5-T1-128
V5-T1-141
V5-T1-157
V5-T1-193
V5-T1-216
V5-T1-229

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Contents

Relays and Timers

Description

Page

Relays and Timers
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-4
V5-T1-5
V5-T1-6
V5-T1-12
V5-T1-16

1
1
1
1
1

An Eaton
Green Solution

Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-18
V5-T1-35
V5-T1-128
V5-T1-141
V5-T1-157
V5-T1-193
V5-T1-216
V5-T1-229

1
1
1
1
1
1

Relays and Timers
Product Description
Eaton’s new line of XT relays
and timers includes mini and
standard frame control relays
and auxiliary contacts, mini
electronic on-delay and
multi-function timers and
an electronic star-delta
(wye-delta) timer for use
in star-delta (wye-delta)
combinations. Because XT
meets UL®, CSA® and CE
standards, it is the perfect
product solution for IEC
applications all over the
world. The compact, space
saving and easy to install XT
line of IEC contactors and
starters is the efficient and
effective solution for
customer applications.

Features
●

●

●

●

●
●

●

●

For use with mini and
standard frame size
contactors and starters
Control relays
●
AC control from 12V to
550V 50 Hz, 600V 60 Hz
●
DC control from
12V to 220V
On-delay and multifunction timers
●
24–240 Vac/Vdc control
Available with screw or
spring cage terminals
Four-pole configurations
IP20 finger and back-ofhand proof
Large ambient temperature
range: –25° to 50°C [–13°
to 122°F]

1

Standards and Certifications
●
●
●
●

IEC EN 60947
CE approved
UL
CSA

1
1
1
1

Instructional Leaflets
Pub51219
XTRM Mini Control Relays

1

Pub51210

XTRE Control Relays

Pub51244

XTTR Electronic Star-Delta (Wye-Delta) Timer

Pub51245

XTMT Mini Electronic On-Delay and
Multi-Function Timers

1
1
1
1
1

The XTRE control relays
have positively driven
contacts between the relay
and the auxiliary contact
modules as well as within
the auxiliary contact
modules

1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-3

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Catalog Number Selection
XT—Relays

1

XT RE C 10 B 22 AD

1
1

Product Line Prefix
XT = XT IEC power control

1

Product Family Code
RM = Mini IEC control
relay
RE = IEC control relay

1

Terminations
Blank = Screw
terminals
C
= Spring cage
terminals

1
XT—Timers

1
1
1

Coil Code
See table on Page V5-T1-5.

Conventional Thermal
Current Rating
10 = 10A

1
1

Frame
XTRM
A = 45 mm—mini
XTRE
B = 45 mm—standard

Contact
Configuration
40 = 4NO
31 = 3NO-1NC
22 = 2NO-2NC

XT MT 6 B 30S 11 B
Product Line Prefix
XT = XT IEC power control

1
1

Product Family Code
MT = Mini IEC timing
relay
TR = Electronic timing
relay star-delta
(wye-delta)

Conventional
Thermal Current
Rating
6 = 6A
Frame
A = 45 mm

1
1
1

Time Range Max.
XTMT
30S = 1.5–30s
60H = 05–1s
0.15–3s
0.5–10s
3–60s
0.15–3 min
0.5–3 min
3–60 min
0.15–3h
0.5–3h
3–60h
XTTR
60S = 3–60s

1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-4

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Function
XTMT
11 = On-delay
70 = Adjustable
XTTE
51 = Star-delta

Coil Code
B = 24–240 Vac/Vdc

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Product Selection

1

When Ordering
●
Orders must be placed in multiples of the package quantity listed
●
DC operated control relays have a built-in suppressor circuit
●
Contact terminal numbers to EN50011
●
Coil terminal numbers to EN50005

TRM10A_

1
1
1
1

Mini Control Relays
Rated Operational Current
AC-15 Ie (A)

Conventional
Thermal
Current Ith (A)

Contact
Configuration

220–240V

380–415V

500V

10

4NO

6

3

1.5

Circuit
Symbol

Screw Terminal
Catalog Number 1

A1 13 23 33 43

XTRM10A40_

3NO-1NC

6

3

1.5

A1 13 21 33 43

XTRM10A31_

A2 14 22 34 44
10

2NO-2NC

6

3

1.5

A1 13 21 31 43

1
1

A2 14 24 34 44
10

1

XTRM10A22_

A2 14 22 32 44

1
1
1
1

XTREC10_

1

Control Relays
Conventional
Thermal
Current Open
at 60°C I th (A)

Contact
Configuration

16

4NO

Rated Operational Current
AC-15 Ie (A)
220–240V

380–415V

500V

6

4

1.5

Circuit
Symbol

A1 13 23 33 43

Screw Terminal
Catalog Number 1

Spring Cage
Terminal
Catalog Number 1

XTRE10B40_

XTREC10B40_

3NO-1NC

6

4

1.5

A1 13 21 33 43

XTRE10B31_

XTREC10B31_

XTRE10B22_ 2

XTREC10B22_ 2

A2 14 22 34 44
16

2NO-2NC

6

4

1.5

A1 13 21 31 43

1
1

A2 14 24 34 44
16

1

1
1

A2 14 22 32 44

1
1
1

Coil Voltage Suffix
Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

110V 50 Hz, 120V 60 Hz

A

415V 50 Hz, 480V 60 Hz

C

380V 50 Hz, 440V 60 Hz

L

120 Vdc

AD

220V 50 Hz, 240V 60 Hz

B

550V 50 Hz, 600V 60 Hz

D

380V 60 Hz

P

220 Vdc

BD

230V 50 Hz

F

208V 60 Hz

E

12V 50/60 Hz

R

12 Vdc

RD

24V 50/60 Hz

T

190V 50 Hz, 220V 60 Hz

G

42V 50 Hz, 48V 60 Hz

W

48 Vdc

WD

24 Vdc

TD

240V 50 Hz, 277V 60 Hz

H

48V 50 Hz

Y

120 Vdc

AD

1
1
1
1

Notes
1 Underscore (_) indicates magnet coil suffix required. See Coil Voltage Suffix table above.
2 DC operated control relays XTRE(C)10B22_ can only be combined with two-pole auxiliary contacts.

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-5

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Accessories
Auxiliary Contacts
XTMCXF_

Front-Mount Auxiliary Contacts for Use with XTRM Mini Control Relays
Rated Operational Current
AC-15 Ie (A)

1
1

Conventional
Thermal Current,
I th Open (A)

220V
230V
240V

380V
400V
415V

500V

Contact
Configuration

10

4

2

1.5

2NC

1

Contact Sequence

51 61

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTMCXFA02

5

XTMCXFA11

5

XTMCXFA20

5

XTMCXFA04

5

XTMCXFA13

5

XTMCXFA22

5

XTMCXFA31

5

XTMCXFA40

5

XTMCXFAL22 2

52 62

1

10

4

2

1.5

1NO-1NC

1

53 61
54 62

1

10

4

2

1.5

2NO

1

53 63
54 64

1

10

4

2

1.5

4NC

1

51 61 71 81
52 62 72 82

1

10

4

2

1.5

1NO-3NC

1

53 61 71 81
54 62 72 82

1

10

4

2

1.5

2NO-2NC

1
1

10

4

2

1.5

3NO-1NC

1

53 61 71

83

54 62 72

84

53 61 73 83
54 62 74 84

10

1

4

2

1.5

4NO

53 63 73 83
54 64 74 84

1
10

1

4

2

1.5

1NO-1NC
1NOE-1NCL

1

57 65 71

83

58 66 72

84

Notes
1 Orders must be placed in multiples of package quantity listed.
2 One early-make contact (NO ), one late-break contact (NC ).
E
L

1
1
1
1
1
1
1
1
V5-T1-6

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Front-Mount Auxiliary Contacts for Use with XTRE Control Relays 1

1

Rated Operational Current AC-15 Ie (A)

Two-Pole

Conventional
Thermal Current,
Ith (A), Open at 60°C
16

Poles

220V
230V
240V

380V
400V
415V

500V

Contact
Configuration

2

6

3

1.5

2NO

Circuit Symbol

53 63

Pkg.
Qty. 2

Screw Terminal
Catalog Number

5

XTCEXFAC20

5

XTCEXFAC11 3

2

6

3

1.5

1NO-1NC

53 61

5

XTCEXFAC02

5

XTCEXFALC11 4

5

XTCEXFAC40 3

5

XTCEXFAC31 3

5

XTCEXFAC22 3

5

XTCEXFAC13

54 62
16

2

6

3

1.5

2NC

51 61

2

6

3

1.5

1NOE-1NCL

57 65
58 66

Four-Pole

16

4

6

3

1.5

4NO

53 6373 83
54 6474 84

16

4

6

3

1.5

3NO-1NC

53 61 73 83
54 62 74 84

16

4

6

3

1.5

2NO-2NC

53 61 71 83
54 62 72 84

16

4

6

3

1.5

1NO-3NC

536171 81

4

6

3

1.5

4NC

51 61 71 81

5

XTCEXFAC04

5

XTCEXFCLC22 4

52 62 72 82
16

4

6

3

1.5

1NO-1NC
1NOE-1NCL

5765 71 83

1
1
1
1
1
1
1
1

54 62 72 82
16

1
1

52 62
16

1
1

54 64
16

1

1
1
1

58 66 72 84
Notes
1 Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NO and NC contacts) and between the
E
L
auxiliary contacts and built-in contacts of the XTRE control relays.
2 Orders must be placed in multiples of package quantity listed.
3 Catalog number is shown with screw type terminal. For spring cage, add a “C” before the last 2 digits. For example, to order a spring cage version of the XTCEXFAC22,
change the catalog number to XTCEXFACC22.
4 One early-make contact (NO ), one late-break contact (NC ).
E
L

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-7

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Suppressors
For AC operated contactors 50–60 Hz. On DC operated contactor relays and on XTRE10B, the
suppressor circuit is built-in. Note dropout delay.

Varistor Suppressor 12
Varistor Suppressor for XTRE

XTCEXVSB_

1

For Use
with…

Contact Sequence

24–48

XTRE(C)10B

A1

130–240

Catalog Number

10

XTCEXVSBW
XTCEXVSBA

10

XTCEXVSBB

10

XTCEXVSBC

Circuit Symbol

Pkg.
Qty. 3

Catalog Number

10

XTMCXVSW

10

XTMCXVSA

A2

240–500

1

Pkg.
Qty. 3

10

48–130

1
1

Voltage

Varistor Suppressor for XTRM

XTMCXVS_

1

Voltage

1

For Use
with…

24–48

XTRM6A_,
XTRM9A_

A1

48–130

XTRM6A_,
XTRM9A_

A2

1

110–250

XTRM6A_,
XTRM9A_

10

XTMCXVSB

1

380–415

XTRM6A_,
XTRM9A_

10

XTMCXVSN

Contact Sequence

Pkg.
Qty. 3

Catalog Number

10

XTCEXVSLBW

A1

10

XTCEXVSLBB

Pkg.
Qty. 3

Catalog Number

1

XTRM Relay with
Installed Suppressor

1
1

Varistor Suppressor with Integrated LED 12

1

XTCEXVSLB_

Varistor Suppressor for XTRE

1

Voltage

For Use
with…

1

24–48

XTRE(C)10B

130–240

A2

1
1
1

RC Suppressor 12

1

XTCEXRSB_

1
1

RC Suppressor for XTRE
Voltage

For Use
with…

Contact Sequence

24–48

XTRE(C)10B

A1

48–130
110–240

1

A2

240–500

1

10

XTCEXRSBW

10

XTCEXRSBA

10

XTCEXRSBB

10

XTCEXRSBC

Notes
1 Note dropout delay.
2 For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor.
3 Orders must be placed in multiples of package quantity listed.

1
1
1
1
V5-T1-8

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

RC Suppressor 12
XTMCXRS_

1

For Use
with…

Circuit
Symbol

Pkg.
Qty. 4

Catalog Number

24–48

XTRM6A_,
XTRM9A_

A1

10

XTMCXRSW

1

48–130

XTRM6A_,
XTRM9A_

A2

10

XTMCXRSA

1

110–250

XTRM6A_,
XTRM9A_

10

XTMCXRSB

Voltage

XTRM Relay with
Installed Suppressor

1

RC Suppressor for XTRM 3

1
1
1

Free-Wheel Diode Suppressor
In addition to the built-in suppressor circuit for DC actuated contactors. Prevents negative breaking
voltage when contactors are used in combination with a safety PLC.
XTCEXVSLBB

1
1

Free-Wheel Diode Suppressor for XTRE
Voltage

For Use
with…

Pkg.
Qty. 4

Catalog Number

130–240

XTRE10B

10

XTCEXVSLBB

1
1
1

Connector

XTCEXCNC

1

Mechanical Interlock 6

Connector 5

1

Mechanical Interlock

For Use
with…

Pkg.
Qty. 4

Catalog Number

XTRE(C)10B

50

XTCEXCNC

XTCEXMLB

For Use
with…

Pkg.
Qty. 4

Catalog Number

XTRE10B_

5

XTCEXMLB

1
1
1

XTMCXCN

XTRM10A

50

1

XTMCXCN
XTMCXML

XTRM10A_

5

1

XTMCXML

1
1

Notes
1 Note dropout delay.
2 For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor.
3 For AC operated contactors, 50/60 Hz. Note dropout delay.
4 Orders must be placed in multiples of package quantity listed.
5 For mechanically arranging contactors in combinations. Distance between contactors is 0 mm.
6 For two contactors with AC or DC operated magnet system that are horizontally or vertically mounted.
For Frame B, mechanical lifespan is 2.5 x 106 operations and the distance between contactors is 0 mm.

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-9

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Electronic Timer Modules
Front- (top-) mounted timer modules for use with XTRE10B control relays. Can not be combined with top-mount auxiliary
contacts, XTCEXF_.
XTCEXT_

Electronic Timer Modules for XTRE
Voltage

1

Contact Sequence

Timing Range

For Use
with…

Pkg.
Qty. 1

Catalog Number

XTRE10B_

1

XTCEXTEEC11T

On-Delay

1

24 Vac/Vdc

1

200–240 Vac

1

Off-Delay

A1

57 65

100–130 Vac

24 Vac/Vdc

1

0.05–1s
0.5–10s
15–100s

XTCEXTEEC11A
XTCEXTEEC11B

A2

58 66

A1

57 65

0.05–1s

XTRE10B_

1

100–130 Vac

1

200–240 Vac

1

100–130 Vac

24 Vac/Vdc

XTCEXTED1C11A
XTCEXTED1C11B

A2

58 66

0.5–10s

XTRE10B_

1

XTCEXTED10C11T
XTCEXTED10C11A

200–240 Vac

1

XTCEXTED1C11T

XTCEXTED10C11B

24 Vac/Vdc

5–100s

XTRE10B_

1

XTCEXTED100C11T

1

100–130 Vac

XTCEXTED100C11A

200–240 Vac

XTCEXTED100C11B

1

Star-Delta
24 Vac/Vdc

1

A1

57 67

1–30s

XTRE10B_

1

100–130 Vac

XTCEXTEYC20A

200–240 Vac

1

XTCEXTEYC20T

XTCEXTEYC20B

A2

58 68

Sealable Shroud

1

Transparent sealable shroud used to protect
electronic timer modules from unwanted access.

1
1

XTCEXTEE,
XTCEXTED,
XTCEXTEY

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-10

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

1

XTCEXTESHRD

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Mini Electronic Timers
XTMT6A_

1

Mini Electronic On-Delay Timers
Rated Operational Current
Ie AC-11 Amps

Conventional
Thermal Current
Ie (A)

220/230/240V

380/400/440V

Time
Range

Function

6

3

3

1.5–30 sec

Fixed, on-delay

6

3

6

0.05–1 sec
0.15–3 sec
0.5–10 sec
3–60 sec
0.15–3 min
0.5–10 min
3–60 min
0.15–3h
0.5–10h
3–60h

Fixed, on-delay

0.05–1 sec
0.15–3 sec
0.5–10 sec
3–60 sec
0.15–3 min
0.5–10 min
3–60 min
0.15–3h
0.5–10h
3–60h

Adjustable:
on-delay;
fleeting contact
on energization;
flashing; pulse
generating;
ON-OFF

6

3

3

1

Terminal Marking
According to
EN 50042

A1

Catalog Number
XTMT6A30S11B

15

XTMT6A60H11B

1
1
Z1

XTMT6A60H70B

Z2
A1

15

1
1
1

A2 16 18

1
1
1

Electronic Star-Delta (Wye-Delta) Timers
XTTR6A60S51

1
1

16 18

A2

1

1

Electronic Star-Delta (Wye-Delta) Timers
Rated Operational Current
Ie AC-11 Amps

Conventional
Thermal Current
Ie (A)

230V

400V

Time
Range

Function

6

3

3

3–60 sec

Fixed, star-delta

Terminal Marking
According to
EN 50042

Catalog Number
XTTR6A60S51B

17

A1

1
1
1

A2

18

1

28

1

Actuating Voltage
24–240 50/60 Hz
24–240 Vdc
Admissible Cable Length
Cable unscreened, with cable cross-section 0.5–1.5 mm2
Two-core cable
Two-core cable in the same cable duct with the main cable, 50/60 Hz

1

Connection to
Y1/Y2, Z1/Z2
M250
M50

1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-11

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Technical Data and Specifications

1

Relays and Timers

1

General

1
1
1
1
1
1
1

Description

XTRE

XTCEXFAC_

XTCEXTE_

XTRM

XTMCXFA_

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

DIN EN 61812,
IEC/EN 60947,
VDE 060, UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

AC operated

20,000,000

10,000,000

3,000,000

10,000,000

10,000,000

DC operated

20,000,000

10,000,000

3,000,000

20,000,000

20,000,000

Maximum operating frequency (ops/hr)

9000

9000

—

9000

9000

Climatic proofing

1

1

1

1

1

Open (°C, min./max.)

–25/60

–25/60

–40/80

–25/50

–25/50

Enclosed (°C, min./max.)

–25/40

–25/40

–25–60

–25/40

–25/40

Ambient temperature for storage (°C, min./max.)

–40/80

–40/80

–25–40

—

—

As required,
not suspended

As required, except
vertically A1/A2 at
the bottom

As required, except
vertically A1/A2 at
the bottom

Standards

Lifespan, mechanical—operations

Ambient temperature

Mounting position

30°
90°

1

90°

90°

180°

1
1
1
1
1
1
1
1
1
1
1

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Base unit with auxiliary contact module
Make contact

7g

7g

6g

10g

10g

Break contact

5g

5g

6g

8g

8g

Degree of protection

IP20

IP20

IP20

IP20

IP20

Protection against direct contact from the front
when actuated by a perpendicular test finger (IEC 536)

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

AC operated (kg)

0.23

0.05

0.08

0.17

—

DC operated (kg)

0.28

0.05

0.08

0.20

—

Solid (mm2)

1 x (0.75–4)0.
2 x (0.75–2.5)

1 x (0.75–4)0.
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–1.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

Solid or stranded (AWG)

18–14

Weight

Terminal capacity
Screw terminals

18–14

18–14

Terminal screw

M3.5

M3.5

M3.5

M3.5

Pozidriv screwdriver

Size 2

Size 2

Size 2

Size 2

Size 2

1

Standard screwdriver (mm)

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

1

Max. tightening torque (Nm)

1.2

1.2

1.2

1.2

1.2

Solid (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

—
—

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Flexible with or without ferrule DIN 46228 (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

—
—

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

—

18–14

18–14

0.6 x 3.5

0.6 x 3.5

—

0.6 x 3.5

0.6 x 3.5

1

1
1
1
1
1

M3.5

Spring cage terminals

Standard screwdriver (mm)

Note
1 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30.

V5-T1-12

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Relays and Timers, continued
Description

1

XTRE

XTCEXFAC_

XTCEXTE_

XTRM

XTMCXFA_

Interlocked opposing contacts to ZH 1/457,
including auxiliary contact module

Yes

Yes

No

Yes

Yes

Rated impulse withstand voltage (Uimp) Vac

6000

6000

6000

6000

6000

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

III/3

Rated insulation voltage (Ui) Vac

690

690

600

690

690

Rated operational voltage (Ue) Vac

690

500

400

600

600

1

Between coil and auxiliary contacts (Vac)

400

400

250

300

300

1

Between the auxiliary contacts (Vac)

400

400

250

300

300

1

AC-15 220/240V Ie

6

6

Please inquire

6

4

1

380/415V Ie

4

3

Please inquire

3

2

500V Ie

1.5

—

—

1.5

1.5

1

Contacts

1
1

Safe isolation to VDE 0106 Part 101 and Part 101/A1

Rated operational current

1

DC-13 1

1

DC13 L/R <15 ms

1

Contacts in series—voltage:
1—24V

10

10

—

2.5

2.5

1—60V

6

6

—

—

—

2—60V

10

10

—

2.5

2.5

1—110V

3

3

—

—

—

3—110V

6

6

—

1.5

1.5

1—220V

1

1

—

—

—

3—220V

5

5

—

0.5

0.5

1
1
1
1

DC13 L/R <50 ms

1

Contacts in series—voltage:
3—24V

4

—

—

—

—

3—60V

4

—

—

—

—

3—110V

2

—

—

—

—

3—220V

1

—

—

—

—

Control circuit reliability
(at Ue = 24 Vdc, Umin = 17, Imin = 5.4 mA)

Failure rate = <10–8, <1 failure
in 100 million operations

—

Failure rate = <10–8, <1 failure
in 100 million operations

Conventional thermal current (Ith)

16

6

10

16

1
1
1
1

10

Short-circuit rating without welding

1

Maximum overcurrent protective device
220/240V–XTPR Frame B

4

—

—

4

4

380/415V–XTPR Frame B

4

—

—

4

4

500V (A gG/gL)

10

10

6

6

6

500V (A fast)

—

—

—

10

10

AC operated (W)

0.3

0.3

—

0.2

0.2

DC operated (W)

0.3

0.3

—

0.3

0.3

1
1

Short-circuit protection, max. fuse

1

Current heat losses at load of Ith

1
1

Note
1 Making and breaking conditions to DC13, time constant as stated.

1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-13

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Relays and Timers, continued
Description

XTRE

XTCEXFAC_

XTCEXTE_

XTRM

XTMCXFA_

Single-voltage coil 50 Hz and dual-voltage coil 50 Hz,
60 Hz (pickup x Uc)

0.8–1.1

—

0.85–11

0.8–1.1

—

Dual-frequency coil 50/60 Hz (pickup x Uc)

0.8–1.1

—

—

0.85–1.1

—

Magnet Systems
Pickup and dropout values
AC operated

DC operated 1
Pickup voltage (pickup x Uc)

0.8–1.1

—

0.7–1.2

0.85–1.3

—

At 24V: without auxiliary contact module (40°C) (pickup x Uc)

0.7–1.3

—

—

0.7–1.3

—

Pickup VA

24

—

—

25

—

Pickup W

19

—

—

22

—

Sealing VA

3.4

—

2

4.6

—

Sealing W

1.2

—

1.8

1.3

—

Pickup VA

27

—

—

30

—

Pickup W

22

—

—

26

—

Power consumption
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz

Dual-frequency coil 50/60 Hz at 50 Hz

Sealing VA

4.2

—

—

5.4

—

Sealing W

1.4

—

—

1.6

—

—

Dual-frequency coil 50/60 Hz at 60 Hz

1

Pickup VA

25

—

—

29

Pickup W

21

—

—

24

—

1

Sealing VA

3.3

—

—

3.9

—

1

Sealing W

1.2

—

—

1.2

—

DC operated

1

Duty factor (% DF)

1
1
1
1
1
1

Pull-in = sealing (W)

3

—

—

2.6

—

100

—

100

100

—

AC operated closing delay (ms)

<21

—

—

14–21

—

AC operated NO contact opening delay (ms)

<18

—

—

8–18

—

AC operated with auxiliary contact module,
max. closing delay (ms)

—

—

—

45

45

DC operated closing delay (ms)

<31

—

—

26–35

—

DC operated NO contact opening delay (ms)

<12

—

—

15–25

—

DC operated with auxiliary contact module,
max. closing delay (ms)

—

—

—

70

70

Switching times at 100% Uc (approximate values)

Note
1 Smoothed DC or three-phase bridge rectifier.

1
1
1
1
1
1
1
V5-T1-14

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Control Relays—Characteristic Curves

1

XTRE (AC-15)

XTRE (DC-13) 1

Component lifespan (operations)
Ie = Rated operational current

Component lifespan (operations)
Ie = Rated operational current

1
1

106

106

20

20

10

10

5

5

1

2

2

1

1

1

1

0.5

0.5
AC-15

0.2

0.2

240 V
0.1
0.01 0.02 0.05 0.1 0.2

0.5

1

2

1

24 V

1

L = 50 ms
R

0.1
0.01 0.02 0.05 0.1 0.2

5 10 A
Ie

1

DC-13

1
0.5

1

2

5 10 A
Ie

1

The diagrams show the closing and opening travel of the contact of the contactor relays and auxiliary contacts at no load.
Tolerances are not taken into consideration.

1
1

Contact Travel Diagrams

1

XTRE
XTRE_ — AC Operation

1

XTRE — DC Operation

Normally open contact

Normally open contact
0

3.3

0

4.5

Normally closed contact

2.1 2.9

Normally closed contact
0

0

4.5

1.0

XTCEXFAC_ — AC Operation

2.9

0.7

Normally open contact
0

0

3.2 4.5

Normally closed contact

2.3 2.9

1

2.9

1

Normally closed contact
0

0

4.5

1.6

XTCEXFALC_ — AC Operation

0.7

XTCEXFALC_ — DC Operation

Normally open contact (early make)

1

Normally open contact (early make)
0

2.0

0

4.5

Normally closed contact (late make)

1.1

2.9

Normally closed contact (late make)
0

2.8

0

4.5

1
1

XTCEXFAC_ — DC Operation

Normally open contact

1

1.9

2.9

Note
1 Making and breaking conditions to DC-13, time constant as stated.

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-15

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Flow Diagrams—Electronic Timers, XTMT Mini Timers

Approximate Dimensions in mm [in.]

On-Delay

Mini Contactor Relays

A1-A2
15-18

t

1

Dimensions

Mini Control Relay XTRM
LED

5.5 [.22]

1
1
1

ON-OFF Function

OFF

A1-A2
15-18

ON OFF

t

LED

1

Flashing, Pulse Initiating

t

1

58
[2.28]

t

t

XTRM Mini Control Relay with RC or Varistor Suppressor
Pulse Generating
A1-A2
0.5 s

t

62.5
[2.46]

15-18
LED

45
[1.77]

XTRM Mini Control Relay with XTMCXFA Auxiliary Contact

Star-Delta

1

M4

t

A1-A2
17-18
17-28

tu

Power LED
LED
LED

1
1
1

Rating Data

1

Rating Data for Approved Types

1

52 – 54
[2.05] – [2.13]

Star-Delta (Wye-Delta) Timer

1

1

65.3
[2.57]

45
[1.77]

t

1

1

45
[1.77]

LED

1

1

43
[1.69]

A1-A2
15-18

1

1

XTRM Mini Control Relay with IP40 XTMCX Shroud

A1-A2
15-18

1

1

52 – 54
[2.05] – [2.13]

Fleeting Contact on Energization

1

1

45
[1.77]

LED

1
1

58
[2.28]

Pilot Duty

58
[2.28]

50
[1.97]

45
[1.77]

83 – 86
[3.27] – [3.39]

General Use

Control Relays—XTMR
A600, P300

10A–600 Vac
0.5A–250 Vdc

Timers—XTMT, XTTR
B300

6A–250 Vac

1
1
V5-T1-16

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

35
[1.38]

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in.]

1

Control Relays

1

Control Relay XTRE with XTCEXFA Auxiliary Contact

Control Relay XTRE with XTCEXMLB Mechanical Interlock

68
45
18
[2.68] [1.77] [.71]

68
45
[2.68] [1.77]

18
[.71]

1
1

6.5
[.26]
75
[2.95]

45
[1.77]

1

6.5
[.26]
75
[2.95]

90
[3.54]
117
[4.61]

Control Relay with Spring Cage Terminals XTREC
with XTCEXFA Auxiliary Contact

1

1
1
1

Coil Suppressors for Use with XTRE Control Relays

1
Approx.
28
[1.10] 32 [1.26]

68 52.3 26.4
[2.68] [2.06] [1.04]

1
1

25.9
[1.02]
36
[1.42]
45
[1.77]

6.5
[.26]

75
[2.95]

125
[4.92]

1
1

9
[.35]

19.2
[.76]
25
[.98]

1
1

Electronic Timer Module XTCEXTE

1

25
[.98]

38
[1.50]

1
45
[1.77]

70
[2.76]

1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-17

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Contents

XTMC Miniature Contactor

Description

1
1
1
1
1

Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1

Miniature Controls

1

Product Description

1
1
1
1
1
1
1
1
1
1
1

V5-T1-3
V5-T1-19
V5-T1-20
V5-T1-24
V5-T1-27
V5-T1-32
V5-T1-34

An Eaton
Green Solution

1

1

Page

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Eaton’s new line of XT
miniature controls includes
non-reversing and reversing
mini contactors, mini overload
relays and snap-on
accessories. A wide range of
applications is possible,
including small electrical
motors from fractional to 5 hp
(460 Vac) or up to 4 kW (400
Vac).

Application Description
Due to its compact size, the
XT line of mini controls is
best suited to be applied in
light-duty loads, such as
hoisting, packaging, material
handling, heating, lighting and
automation systems. XT mini
contactors are a particularly
compact, economic and
environmentally friendly
solution wherever control
of small motors or loads
is required.

Features

Standards and Certifications

Mini Contactors—Types XTMC
and XTMF, 6–9A
●
AC control from 12V to
550V 50 Hz, 600V 60 Hz
●
DC control from
12V to 220V
●
Reversing or non-reversing
●
Three- and four-pole
configurations
●
Three-pole XTMC
●
Four-pole XTMF
●
●

●
●

●

Panel or DIN rail mounting
IP20 finger and back-ofhand proof
Low noise operation
High degree of climatic
proofing
Large ambient temperature
range –25° to 50°C [–13° to
122°F]

Mini Overload Relays—
Bimetallic Type XTOM
●
Phase failure sensitivity
●
Direct mount to XTMC and
XTMF mini contactors
●
Trip Class 10
●
11 settings to cover
0.1 to 12A
●
Ambient temperature
compensated –5° to 50°C
[23° to 122°F]
●
Manual and automatic
reset by selector switch
●
One make (NO) or one
break (NC) auxiliary contact
as standard
●
Test/Off button
●
Trip-free release

1
1
1
1
1
1
V5-T1-18

Volume 5—Motor Control and Protection

V5-T1-35
V5-T1-128
V5-T1-141
V5-T1-157
V5-T1-193
V5-T1-216
V5-T1-229

CA08100006E—August 2012

www.eaton.com

●
●
●
●
●
●

IEC EN 60947
CE approved
UL
CSA
CCC
ATEX

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Instructional Leaflets

1

Pub51219

XTMC, XTMF Mini Contactors, XTRM Mini
Control Relay and Accessories

Pub51243

XTOM Mini Overload Relays

Pub51206

Mini Reversing Link Kits

1

MN03402002E XTOM Mini Overload Relays Installation
and User Manual

1

1

1
1
1

Catalog Number Selection

1

XT IEC Miniature Contactors

1

XT MC 6 A 10 A
Designation
XT = XT IEC power control

Type
MC = Three-pole FVNR
mini IEC contactor
MF = Four-pole FVNR mini
IEC contactor
MR = Three-pole FVR mini
IEC contactor

A =
B =
F =
T =
TD =
C =
D =
E =
G =
H =

Current Rating,
AC-3
XTMC
6 = 6.6A
9 = 8.8A
XTMF
9 = 8.8A
Frame Size
A = 45 mm mini

1
Coil Codes
110V 50 Hz, 120V 60 Hz L =
220V 50 Hz, 240V 60 Hz N =
230V 50 Hz
P =
24V 50/60 Hz
R =
24 Vdc
W =
415V 50 Hz, 480V 60 Hz Y =
550V 50 Hz, 600V 60 Hz AD =
208V 60 Hz
BD =
190V 50 Hz, 220V 60 Hz RD =
240V 50 Hz, 277V 60 Hz WD =

380V 50 Hz, 440V 60 Hz
400V 50 Hz
380V 60 Hz
12V 50/60 Hz
42V 50 Hz, 48V 60 Hz
48V 50 Hz
120 Vdc
220 Vdc
12 Vdc
48 Vdc

Integral Auxiliary Contact
01 = 1NC
10 = 1NO

1
1
1
1
1
1
1
1

XT IEC Miniature Overload Relays

1
XT OM P16 A C1

Designation
XT = XT IEC power control

Type
OM = Mini overload relay
P16
P24
P40
P60
001
1P6

=
=
=
=
=
=

Overload Release
0.1–0.16A
2P4 = 1.6–2.4A
0.16–0.24A
004 = 2.4–4A
0.24–0.4A
006 = 4–6A
0.4–0.6A
009 = 6–9A
0.6–1A
012 = 9–12A
1–1.6A

1
Frame Size
A = 45 mm mini

1

Trip Class
C1 = Class 10A

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-19

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Product Selection
Full Voltage Non-Reversing Miniature Contactors
XTMC_

1

Maximum UL Ratings—Single-Phase and Three-Phase
Horsepower Ratings
Single-Phase

Three-Phase

115V

200V

230V

200V

230V

460V

575V

Number of
Power Poles

Auxiliary
Contacts

Screw Terminal
Catalog Number 1

1/4

3/4

1

1-1/2

2

3

3

3

1NO

XTMC6A10_

1/4

3/4

1

1-1/2

2

3

3

3

1NC

XTMC6A01_

1/2

1

1-1/2

2

3

5

5

3

1NO

XTMC9A10_

1/2

1

1-1/2

2

3

5

5

3

1NC

XTMC9A01_

1

1/2

1

1-1/2

2

3

5

5

4

—

XTMF9A00_

1

Maximum IEC Ratings AC-3

1

Operational Current
AC-3 Amp Rating
380/400V

Conventional Free
Air Thermal Current
AC-1 at 50°C

220–
240V

380–
400V

550V

660/
690V

Number of
Power Poles

Auxiliary
Contacts

Screw Terminal
Catalog Number 1

1

6.6

20

1.5

3

3

3

3

1NO

XTMC6A10_

6.6

20

1.5

3

3

3

3

1NC

XTMC6A01_

8.8

20

2.2

4

4

4

3

1NO

XTMC9A10_

8.8

20

2.2

4

4

4

3

1NC

XTMC9A01_

8.8

20

2.2

4

4

4

4

—

XTMF9A00_

1
1
1

1
1
1
1
1

Three-Phase Motors 50–60 Hz

Magnet Coil Suffix
Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

110V 50 Hz, 120V 60 Hz

A

415V 50 Hz, 480V 60 Hz

C

380V 60 Hz

P

120 Vdc

AD

220V 50 Hz, 240V 60 Hz

B

550V 50 Hz, 600V 60 Hz

D3

12V 50/60 Hz

R3

220 Vdc

BD

1

230V 50 Hz

F

208V 60 Hz

E

42V 50 Hz, 48V 60 Hz

W

12 Vdc

RD

24V 50/60 Hz

T

190V 50 Hz, 220V 60 Hz

G

48V 50 Hz

Y

48 Vdc

WD

1

24 Vdc

TD 2

240V 50 Hz, 277V 60 Hz

H

—

—

—

—

—

—

380V 50 Hz, 440V 60 Hz

L

—

—

—

—

1
1
1
1

Notes
IEC Utilization Categories, see Page V5-T1-242.
AC-1: Non-inductive or slightly inductive loads.
AC-3: Squirrel cage motors—starting, switching of motors during running.
AC-4: Squirrel cage motors—starting, plugging, inching.
1
2
3

Underscore (_) indicates magnetic coil suffix required.
With DC operation: Integrated diode resistor combination, coil rating 2.6W.
XTMF four-pole contactor not available with “D” or “R” coil voltage suffix.

1
1
1
1
1
1
1
1
1
V5-T1-20

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Full Voltage Reversing Miniature Contactors
XTMR_

1

Maximum UL Ratings—Single-Phase and Three-Phase

1

Horsepower Ratings
Single-Phase

Three-Phase

Spare Auxiliary Contacts

115V

200V

230V

200V

230V

460V

575V

1/4

3/4

1

1-1/2

2

3

3

1/2

1

1-1/2

2

3

5

K1M

5

K2M

63

63

64

64

63

63

64

64

Catalog Number 12
XTMR6A21_

XTMR9A21_

1
1
1
1
1

Maximum IEC Ratings AC-3

1

Three-Phase Motors 50–60 Hz
Operational Current
AC-3 Amp Rating
380/400V

Conventional Free
Air Thermal Current
AC-1 at 50°C

220/
230/
240V

380/
400/
440V

500V

660/
690V

6.6

20

1.5

3

3

3

8.8

20

2.2

4

4

4

Spare Auxiliary Contacts
K1M

K2M

63

63

64

64

63

63

64

64

Catalog Number 12
XTMR6A21_

XTMR9A21_

1
1
1
1
1

Magnet Coil Suffix
Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

110V 50 Hz, 120V 60 Hz

A

415V 50 Hz, 480V 60 Hz

C

380V 60 Hz

P

120 Vdc

AD

220V 50 Hz, 240V 60 Hz

B

550V 50 Hz, 600V 60 Hz

D3

12V 50/60 Hz

R3

220 Vdc

BD

230V 50 Hz

F

208V 60 Hz

E

42V 50 Hz, 48V 60 Hz

W

12 Vdc

RD

24V 50/60 Hz

T

190V 50 Hz, 220V 60 Hz

G

48V 50 Hz

Y

48 Vdc

WD

24 Vdc

TD 2

240V 50 Hz, 277V 60 Hz

H

—

—

—

—

—

—

380V 50 Hz, 440V 60 Hz

L

—

—

—

—

1
1

2

3

1
1

Notes
IEC Utilization Categories, see Page V5-T1-242.
AC-1: Non-inductive or slightly inductive loads.
AC-3: Squirrel cage motors—starting, switching of motors during running.
AC-4: Squirrel cage motors—starting, plugging, inching.
1

1

1
1

Underscore (_) indicates magnetic coil suffix required. See Magnet Coil Suffix table above.
The factory-installed reversing mini contactor includes (2) XTMC…01 contactors, (2) XTMCXFA20 2NO front-mount auxiliary contacts
(1) XTMCXRL reversing link kit and (1) XTMCXML mechanical interlock.
XTMF four-pole contactor not available with “D” or “R” coil voltage suffix.

1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-21

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Star-Delta (Wye-Delta) Miniature Contactors

XTMC_

Maximum Current UL Ratings—Single-Phase and Three-Phase 1
Horsepower Ratings

1

115V

200V

230V

200V

230V

460V

575V

Maximum
Changeover
Time (sec.)

1/2

1

1-1/2

2

3

5

7-1/2

30

Single-Phase

1

Three-Phase

Spare Auxiliary Contacts
K1M

21 31 53

1

22 32 54

1
1

Component
Description

Catalog Number 2

K1M main contactor

XTMC9A10_

K1M auxiliary contact

XTMCXFC22

K5M delta contactor

XTMC9A01_

K3M star contactor

XTMC9A10_

K3M auxiliary contact

XTMCXFC02

K1T timing relay

XTTR6A60S51B

Component
Description

Catalog Number 2

1
Maximum IEC Ratings AC-3 1

1

Horsepower Ratings

1

Three-Phase Motors 50–60 Hz
220/230/240V

380/400/440V

500V

Maximum
Changeover
Time (sec.)

1

4

5.5

5.5

30

Spare Auxiliary Contacts
K1M

21 31 53
22 32 54

1
1
1
1
1
1
1
1
1
1
1

Mini Overload Relay Settings (A)
Setting

Starting

A: IN x 0.58
Motor protection in the Y and delta configurations.

<15 sec

B: IN x 1
Only partial motor protection in star position

15–40 sec

C: IN x 0.58
Motor not protected in star position.

>40 sec

Timing relay set to approximately 10 sec.
Notes
Depending on the coordination type required (i.e., Type 1 or Type 2) it must be established
whether the fuse protection and the input wiring for the main and delta contactors are to be
common or separate.
1
2

Operating frequency: 30 starts/hour. See Magnet Coil Suffix table on following page.
Underscore (_) indicates magnet coil suffix required.

1
1
1
1
1
1
1
1
V5-T1-22

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

K1M main contactor

XTMC9A10_

K1M auxiliary contact

XTMCXFC22

K5M delta contactor

XTMC9A01_

K3M star contactor

XTMC9A10_

K3M auxiliary contact

XTMCXFC02

K1T timing relay

XTTR6A60S51B

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Magnet Coil Suffix
Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

110V 50 Hz, 120V 60 Hz

A

415V 50 Hz, 480V 60 Hz

C

400V 50 Hz

N

120 Vdc

AD

220V 50 Hz, 240V 60 Hz

B

550V 50 Hz, 600V 60 Hz

D

380V 60 Hz

P

220 Vdc

BD

230V 50 Hz

F

208V 60 Hz

E

12V 50/60 Hz

R

12 Vdc

RD

24V 50/60 Hz

T

190V 50 Hz, 220V 60 Hz

G

24V 50 Hz

U

48 Vdc

WD

24 Vdc

TD 1

240V 50 Hz, 277V 60 Hz

H

42V 50 Hz, 48V 60 Hz

W

—

—

—

—

380V 50 Hz, 440V 60 Hz

L

48V 50 Hz

Y

—

—

1
1
1
1
1

Mini Overload Relays
XTOM_

1

1

Mini Overload Relays 23
Short-Circuit Protection (A)
Overload
Release It

Trip
Class

0.1–0.16A

10A

1

Contact
Configuration

Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

97 95

1NO-1NC

20

0.5

15

—

XTOMP16AC1

2 4 6 98 96

Contact
Sequence

0.16–0.24A

10A

1NO-1NC

20

1

15

—

XTOMP24AC1

0.24–0.4A

10A

1NO-1NC

20

2

15

—

XTOMP40AC1

0.4–0.6A

10A

1NO-1NC

20

2

15

—

XTOMP60AC1

0.6–1A

10A

1NO-1NC

20

4

15

3

XTOM001AC1

1–1.6A

10A

1NO-1NC

20

6

15

6

XTOM1P6AC1

1.6–2.4A

10A

1NO-1NC

20

6

15

6

XTOM2P4AC1

2.4–4A

10A

1NO-1NC

20

15

15

XTOM004AC1

4–6A

10A

1NO-1NC

20

15

20

XTOM006AC1

6–9A

10A

1NO-1NC

20

15

35

XTOM009AC1

9–12A

10A

1NO-1NC

—

—

45

XTOM012AC1

1
1
1
1
1
1
1
1

Notes
1 With DC operation: Integrated diode resistor combination, coil rating 2.6W.
2 Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. See MN03402002E for more information.
3 When fitted directly to the contactor, a clearance of at least 5 mm is required between the overload relays.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-23

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Accessories
Auxiliary Contacts
Front-mounted snap-on auxiliary contacts for mini contactors are available with screw terminals in a
variety of contact configurations. Auxiliary contact modules are standard with interlocked opposing
contacts, except in the case of early-make or late-break contacts.

1

Front-Mount Auxiliary Contacts for Use with Mini Contactors

1

Conventional Free Air
Thermal Current,
Ith = Ie, AC-1 in Amps

Contact
Configuration

1

10

2NC

Contact Sequence

21 31

1

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTMCXFC02

5

XTMCXFD11

5

XTMCXFC22

5

XTMCXFA02

5

XTMCXFA11

5

XTMCXFA20

5

XTMCXFA04

5

XTMCXFA13

5

XTMCXFA22

5

XTMCXFA31

5

XTMCXFA40

5

XTMCXFAL22 2

22 32

1

10

1NO-1NC

1
1

10

2NO-2NC

1

21

33

22

34

21 31 43 53
22 32 44 54

10

1

2NC

51 61

1

52 62
10

1

1NO-1NC

53 61

1

54 62
10

1

2NO

53 63

1

54 64
10

1

4NC

51 61 71 81
52 62 72 82

1

10

1NO-3NC

1

53 61 71 81
54 62 72 82

1

10

2NO-2NC

1
1

10

3NO-1NC

1

53 61 71

83

54 62 72

84

53 61 73 83
54 62 74 84

1

10

4NO

1

53 63 73 83
54 64 74 84

1

10

1
1

1NO-1NC
1NOE-1NCL

57 65 71

83

58 66 72

84

Notes
1 Orders must be placed in multiples of package quantity listed.
2 One early-make contact (NO ), one late-break contact (NC ).
E
L

1
V5-T1-24

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Suppressors
XTMCXR_

1
RC Suppressor 1
Voltage

XTMC Relay with
Installed Suppressor

For Use
with…

24–48

XTMC6A_,
XTMC9A_

48–130

XTMC6A_,
XTMC9A_

110–250

XTMC6A_,
XTMC9A_

1

Circuit Symbol

Pkg.
Qty. 2

Catalog Number

A1

10

XTMCXRSW

10

XTMCXRSA

10

XTMCXRSB

A2

1
1
1
1
1
1
1

XTMCX_

Varistor Suppressor 3
Voltage

XTMC Relay with
Installed Suppressor

For Use
with…

1

Circuit Symbol

Pkg.
Qty. 2

Catalog Number

24–48

XTMC6A_,
XTMC9A_

A1

10

XTMCXVSW

48–130

XTMC6A_,
XTMC9A_

A2

10

XTMCXVSA

110–250

XTMC6A_,
XTMC9A_

10

XTMCXVSB

380–415

XTMC6A_,
XTMC9A_

10

XTMCXVSN

1
1
1
1
1
1

Mechanical Interlock
XTMCXML

1

Mechanical Interlock

1

Description

Pkg.
Qty. 2

Catalog Number

Mechanical interlock

5

XTMCXML

1
1

Notes
For two contactors with AC or DC operated magnet system that are horizontally or vertically mounted,
the distance between contactors is 0 mm and the mechanical lifespan is 2.5 x 106 operations.
1
2
3

1

For AC operated contactors, 50/60 Hz. Note dropout delay.
Orders must be placed in multiples of package quantity listed.
For AC operated contactors, 50/60 Hz. DC operated contactors have integrated varistor suppressors.

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-25

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Additional Accessories
XTMCXRL

1

Reversing Link Kit 12
Description

Pkg.
Qty. 3

Catalog Number

Main current wiring for reversing contactors and starters

1

XTMCXRL

Pkg.
Qty. 3

Catalog Number

1

XTMCXSDL

Pkg.
Qty. 3

Catalog Number

50

XTMCXCN 6

Description

Pkg.
Qty. 3

Catalog Number

IP40 sealable transparent shroud, snap fitting on mini contactor

1

XTMCXSHROUD

1
1
1

XTMCXSDL

Description

1

Main current wiring for star-delta (wye-delta) combinations.
Includes the star-delta bridge

1
1

Star-Delta (Wye-Delta) Link Kit 45

XTMCXCN

Connector

1

Description

1

For mechanically arranging contactors and timing relays in
combinations

1
1

XTMCXSHROUD

1

IP40 Sealable Transparent Shroud

1
1

Notes
1 The following control cables are integrated as part of the electrical interlock: K1M: A1–K2M: 21; K1M: 21–K2M: A1
2 Reversing link kit does not include mechanical interlock. See Mechanical Interlock.
3 Orders must be placed in multiples of package quantity listed.
4 The following control cables are integrated in addition to the electrical interlock: K3M: A1–K5M: 21; K3M: 21–K5M: A1; K3M: A2–K5M: A2
5 When combined with overload relay, use separate mounting.
6 0 mm distance between contactors.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-26

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

Technical Data and Specifications

1

XT Miniature Controls—General
XTMC6A_
Description

XTMC9A_

1

XTMF9A_

AC Coils

DC Coils

AC Coils

DC Coils

AC Coils

DC Coils

1

Standards

IEC/EN 60947,
VDE 0660, CSA,
UL, CCC

IEC/EN 60947,
VDE 0660, CSA,
UL, CCC

IEC/EN 60947,
VDE 0660, CSA,
UL, CCC

IEC/EN 60947,
VDE 0660, CSA,
UL, CCC

IEC/EN 60947,
VDE 0660, CSA,
UL, CCC

IEC/EN 60947,
VDE 0660, CSA,
UL, CCC

1

Weights in kg [lb]

0.2 [0.44]

0.17 [0.37]

0.2 [0.44]

0.17 [0.34]

0.2 [0.44]

0.17 [0.37]

Physical and Electrical

Mechanical life—operations

10,000,000

20,000,000

10,000,000

20,000,000

10,000,000

10,000,000

Mechanical life—coil at 50 Hz

7

—

7

—

7

—

Maximum mechanical operating frequency (ops/hr)

9000

9000

9000

9000

9000

9000

Insulation voltage (Ui) Vac

690

690

690

690

690

690

1
1
1
1

Impulse withstand voltage (Uimp) Vac

6000

6000

6000

6000

6000

6000

Operational Voltage (Ue) Vac

690

690

690

690

690

690

1

Between coil and contacts (Vac)

300

300

300

300

300

300

Between contacts (Vac)

300

300

300

300

300

300

1

110

110

110

110

110

110

220/230V

90

90

90

90

90

90

380/400V

90

90

90

90

90

90

500V

64

64

64

64

64

64

660/690V

54

54

54

54

54

54

1

Type 2 coordination (A)

10

10

10

10

10

10

1

Type 1 coordination (A)

20

20

20

20

20

20

Degree of protection

IP20

IP20

IP20

IP20

IP20

IP20

1

Flexible with ferrule (mm2)

1 x (0.75–1.5)
2 x (0.75–1.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

1 x (0.75–1.5)
2 x (0.75–1.5)

1

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

18–14

18–14

Terminal screw

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

1

Pozidriv screwdriver

Size 2

Size 2

Size 2

Size 2

Size 2

Size 2

Standard screwdriver (mm)

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

0.8 x 5.5
1x6

Nm

1.2

1.2

1.2

1.2

1.2

1.2

Lb-in

10.6

10.6

10.6

10.6

10.6

10.6

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1

Flexible with ferrule (mm2)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1 x (1–2.5)
2 x (1–2.5)

1

Standard screwdriver (mm)

0.6 x 3.5

0.6 x 3.5

0.6 x 3.5

0.6 x 3.5

0.6 x 3.5

0.6 x 3.5

Mounting position

1

1

1

1

1

1

Safe isolation to VDE 0106 Part 101 and Part 101/A1

Making capacity (amps)

1

Breaking capacity (amps)

1
1

Short-circuit protection rating maximum fuse (gL/gG)

1
1

Max. tightening torque

1
1

Terminal capacity of spring cage main terminals
Solid (mm2)

1
1

Note
1 As required, except vertical with terminals A1/A2 at the bottom.

1
1

A1
A2

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-27

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

XT Miniature Controls—General, continued
XTMC6A_

1

Description

1

Ambient temperature

1

Mechanical shock resistance (IEC/EN 60068-2-27)

1
1
1
1
1
1

XTMC9A_

XTMF9A_

AC Coils

DC Coils

AC Coils

DC Coils

AC Coils

DC Coils

–25° to 50°C
[–13° to 122°F]

–25° to 50°C
[–13° to 122°F]

–25° to 50°C
[–13° to 122°F]

–25° to 50°C
[–13° to 122°F]

–25° to 50°C
[–13° to 122°F]

–25° to 50°C
[–13° to 122°F]

Main contact—make contact

10g

10g

10g

10g

10g

10g

Main contact—break/make contact

10/8g

10/8g

10/8g

10/8g

—

—

Main contact—make contact

10g

10g

10g

10g

10g

10g

Main contact—make/break contact

20/20g

20/20g

20/20g

20/20g

20/20g

20/20g

Climatic proofing

1

1

1

1

1

1

Pollution degree

III/3

III/3

III/3

III/3

III/3

III/3

Environmental

Half-sinusoidal shock 10 ms
Contactor without auxiliary contact module

Contactor with auxiliary contact module

Note
1 Damp heat, constant, to IEC 60 068-2-78; damp heat, cyclic, to IEC 60 068-2-30.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-28

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

XT Miniature Controls—Magnet Systems
XTMC6A_
Description

XTMC9A_

1

XTMF9A_

AC Coils

DC Coils

AC Coils

DC Coils

AC Coils

DC Coils

Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz

0.8–1.1

—

0.8–1.1

—

0.8–1.1

—

Dual frequency coil 50/60 Hz

0.85–1.1

—

0.85–1.1

—

0.85–1.1

—

—

0.8–1.1

—

0.8–1.1

—

0.85–1.1

1

Voltage Tolerance

1

Pickup (x Uc)

DC operated

1

1
1

Power Consumption

1

AC operation
Pickup VA

1

Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz

25

—

25

—

25

—

Dual frequency coil 50/60 Hz at 50 Hz

30

—

30

—

30

—

Dual frequency coil 50/60 Hz at 60 Hz

29

—

29

—

29

—

1

Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz

22

—

22

—

22

—

1

Dual frequency coil 50/60 Hz at 50 Hz

26

—

26

—

26

—

Dual frequency coil 50/60 Hz at 60 Hz

24

—

24

—

24

—

Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz

4.6

—

4.6

—

4.6

—

Dual frequency coil 50/60 Hz at 50 Hz

5.4

—

5.4

—

5.4

—

Dual frequency coil 50/60 Hz at 60 Hz

3.9

—

3.9

—

3.9

—

1
1

Pickup W

1
1

Sealing VA

1

Sealing W
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz

1.3

—

1.3

—

1.3

—

Dual frequency coil 50/60 Hz at 50 Hz

1.6

—

1.6

—

1.6

—

Dual frequency coil 50/60 Hz at 60 Hz

1.1

—

1.1

—

1.1

—

1

—

2.6

—

2.6

—

2.6

1

100

100

100

100

100

100

14

26

14

26

14

26

DC operated 1
Power consumption pickup = sealing (VA/W)
Duty factor (%)

1

Switching Time at 100% Uc

1

Make contact
Closing delay min. (ms)
Closing delay max. (ms)

21

35

21

35

21

35

Opening delay min. (ms)

8

15

8

15

8

15

Opening delay max. (ms)

18

25

18

25

18

25

Closing delay with top-mounting auxiliary contact (ms)

Max. 45

Max. 70

Max. 45

Max. 70

Max. 45

Max. 70

Minimum (ms)

16

40

16

40

16

40

Maximum (ms)

21

50

21

50

21

50

Max. 12

Max. 12

Max. 12

Max. 12

Max. 12

Max. 12

1
1
1

Reversing Contactors

1

Changeover time at 100% Uc

Arcing time at 690 Vac (ms)

1
1

Note
1 Smoothed DC or three-phase bridge rectifier.

1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-29

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

XT Miniature Controls

1

Description

1

Conventional free air thermal current, three-pole, 50–60 Hz (A)

1
1
1
1
1
1
1
1

XTMC6A_
AC Coils

DC Coils

XTMC9A_
AC Coils

DC Coils

XTMF9A_
AC Coils

DC Coils

AC-1 Operation

at 40°C (Ith)

22

22

22

22

22

22

at 50°C (Ith)

20

20

20

20

20

20

at 55°C (Ith)

19

19

19

19

19

19

50

50

50

50

60

60

Conventional free air thermal current, single-pole (Ith)
AC-3 Operation
Rated operational current, 50/60 Hz 1 (Ie) in amperes (A)
220/230V

6.6

6.6

9.0

9.0

9.0

9.0

240V

6.6

6.6

9.0

9.0

9.0

9.0

380/400V

6.6

6.6

9.0

9.0

9.0

9.0

415V

6.6

6.6

9.0

9.0

9.0

9.0

440V

6.6

6.6

9.0

9.0

9.0

9.0

500V

5.0

5.0

6.4

6.4

6.4

6.4

660/690V

3.5

3.5

4.8

4.8

4.8

4.8

Rated power (P) in kilowatts (kW)
220/230V

1.5

1.5

2.2

2.2

2.2

2.2

1

240V

1.8

1.8

2.5

2.5

2.5

2.5

1

380/400V

3.0

3.0

4.0

4.0

4.0

4.0

415V

3.1

3.1

4.3

4.3

4.3

4.3

440V

3.3

3.3

4.6

4.6

4.6

4.6

500V

3.0

3.0

4.0

4.0

4.0

4.0

660/690V

3.0

3.0

4.0

4.0

4.0

4.0

220/230V

5.0

5.0

6.6

6.6

6.6

6.6

240V

5.0

5.0

6.6

6.6

6.6

6.6

380/400V

5.0

5.0

6.6

6.6

6.6

6.6

415V

5.0

5.0

6.6

6.6

6.6

6.6

1

440V

5.0

5.0

6.6

6.6

6.6

6.6

500V

3.7

3.7

5.0

5.0

5.0

5.0

1

660/690V

2.9

2.9

3.4

3.4

3.4

3.4

220/230V

1.1

1.1

1.5

1.5

1.5

1.5

240V

1.3

1.3

1.8

1.8

1.8

1.8

380/400V

2.2

2.2

3.0

3.0

3.0

3.0

1

415V

2.3

2.3

3.1

3.1

3.1

3.1

440V

2.4

2.4

3.3

3.3

3.3

3.3

1

500V

2.2

2.2

3.0

3.0

3.0

3.0

660/690V

2.2

2.2

3.0

3.0

3.0

3.0

12V

20

20

20

20

—

—

24V

20

20

20

20

—

—

60V

20

20

20

20

—

—

110V

20

20

20

20

—

—

220V

20

20

20

20

—

—

1
1
1
1
1

1
1

1
1
1
1
1
1

AC-4 Operation
Rated operational current, 50/60 Hz 1 (Ie) in amperes (A)

Rated power (P) in kilowatts (kW)

DC-1 Operation 2

Notes
1 At maximum permissible ambient temperature.
2 Rated operation current (l ) in amperes, at maximum permissible ambient temperature.
e

V5-T1-30

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

XT Miniature Controls, continued

1

XTMC6A_
AC Coils

DC Coils

XTMC9A_
AC Coils

DC Coils

XTMF9A_
AC Coils

DC Coils

1

12V

6

6

8

8

—

—

24V

6

6

8

8

—

—

1

60V

3

3

4

4

—

—

110V

2

2

3

3

—

—

220V

—

—

—

—

1.0

1.0

1

12V

1.8

1.8

2.5

2.5

—

—

1

24V

1.8

1.8

2.5

2.5

—

—

60V

1.8

1.8

2.5

2.5

—

—

110V

1.1

1.1

1.5

1.5

2.5

2.5

220V

0.2

0.2

0.3

0.3

1.0

1.0

at Ith

2.0

3.5

2.0

3.5

2.7

4.7

at Ie to AC-3/400V

0.3

0.4

0.5

0.7

—

—

Description
DC-3 Operation 1

1

DC-4 Operation 1

1
1
1

Current Heat Loss (Three- or Four-Pole) in Watts

1
1

XT Miniature Controls—Auxiliary Contacts
Description

Built-In Auxiliary
XTMC

Add-On Auxiliary
XTMCXF_

1

Interlocked opposing contacts to ZH1/457, including auxiliary contact module

Yes

Yes

1

Rated impulse withstand voltage, Uimp (Vac)

6000

6000

Overvoltage category/pollution degree

III/3

III/3

Rated insulation voltage, Ui (Vac)

690

690

Rated operational voltage, Ue (Vac)

600

600

1

Between coil and auxiliary contacts

300

300

1

Between the auxiliary contacts

300

300

220/240V

6A

4A

380/415V

3A

2A

500V

1.5A

1.5A

1
1

1

Safe isolation to VDE 0106 Part 101 and Part 101(A) in Vac

1

Rated operational current

1

AC-15, Ie

1

DC-13 (contacts in series)
1: 24V

2.5A

2.5A

2: 60V

2.5A

2.5A

3: 100V

1.5A

1.5A

3: 220V

0.5A

0.5A

Conventional thermal current, Ith

10A

10A

Control circuit reliability (at Ue = 24 Vdc, Umin = 17V, I min = 5.4 mA)

<10–8, <1 failure at 100 million operations

<10–8, <1 failure at 100 million operations

1

AC-15, operations x 106

0.2

0.2

DC-13 L/R = 50 ms: 2 contacts in series at Ie = 0.5A, operations x 106

0.15

0.15

1

Short-circuit protection rating maximum fuse, 500V gG/gL

6A

6A

Short-circuit protection rating maximum fuse, 500V fast

10A

10A

0.2

0.2

1
1

Component lifespan at Ue = 240V

1

Short-circuit rating without welding

Current heat loss at conventional free air thermal current Ith per contact, W

1
1

Note
1 Rated operation current (l ) in amperes, at maximum permissible ambient temperature.
e

1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-31

1
1
1
1
1
1
1
1
1

XT IEC Power Control

Wiring Diagrams

Tripping Characteristics

XTMR Reversing Contactor
Control Circuit

XTMR Reversing Contactor
Power Circuit

2h
100
60
40

21
0
II

22
1 3 5

22

21
22

K1M

21
53

13 5
K2M

2 4 6

54
I
53
54 54
54
K1M
K2M
53
53
22
K1M 22
K2M 21
21
A1 K2M A1
K1M
A2
A2

2 4 6

M1

XTOM

20
10
6
4
2

UV W

1
40

M
3

3-Phase

20

XT Mini Star-Delta (Wye-Delta)
Contactor Power Circuit

1

10
6
4
2-Phase

2
1
0.6

B

1

1
1

Tripping Characteristics Chart

Minutes

1

IEC Contactors and Starters

Seconds

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

1.5 2

3

4

6

x Setting Current
K1M

1

1 3 5
K5M
24 6

13 5
K3M
24 6

A

1 35
246

C

1
U1
V1 M1
W1 3
M1

1
1

V2
W2
U2

1
1
1

These tripping characteristics
are mean values of the
spread at 20°C ambient
temperature in a cold state.
Tripping time depends on
response current. With
devices at operating
temperature, the tripping
time of the overload relay
reduces to approximately
25% of the read off value.
Specific characteristics for
each individual setting range
can be found on Page
V5-T1-33.

1
1
1
1
1
1
1
1
1
1
V5-T1-32

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

8 10 15

20

XT IEC Power Control

Electrical Switching Operation Charts

1

Squirrel cage motors

Squirrel cage motors

Operating characteristics
Starting: from rest
Stopping: after attaining a full running speed

Operating characteristics
Jogging, plugging, reversing

Electrical characteristics
Make (NO): Up to 6x rated motor current
Breaking (NC): 1x rated motor current

Electrical characteristics
Make (NO): 6x rated motor current
Breaking (NC): 6x rated motor current

Normal Switching Duty—AC-3/400V

Extreme Switching Duty—AC-4/400V

1
1
1

22
18.5
15
11
7.5
5.5
4
3
2.2

A
58
43
36
30
23
16
12
8.8

XTMC 9A

6.5

XTMC 6A

5
XTMC DC Coil

1.5

3.5

1.1

2.5

0.8

2

0.55

1.6

XTMC AC Coil

0.01

kW
22
18.5
15
11
7.5
5.5
4
3
2.2
1.5

Rated operational current le 50 – 60 Hz

30

AC-3/400V

Rated output of three-phase motors, 50 – 60 Hz

kW

Rated operational current le 50 – 60 Hz

Rated output of three-phase motors, 50 – 60 Hz

1
AC-4/400V

A
43
36
30

1

23

1

16

1

12

1

8.8
6.5 XTMC 9A

1

5 XTMC 6A

1

3.5

1.1

2.5

0.8

2

0.55

1.6

0.37

1.2

0.25

0.8
0.01

0.04
0.1
0.4 0.75
2
4 6 10
0.02
0.06
0.2
0.6 1
3 5 8
Component lifespan (millions of operations)

1

1
1
1
0.03 0.06
0.2 0.4
1
3 5 8
0.3
0.02 0.04
0.1
0.6
2
4 6 10
Component lifespan (millions of operations)

1
1

Switching Duty for Non-Motor Loads, Three- and
Four-Pole—AC-1/400V
1400
1000
700
500
350
275

Short Time Loading, Three-Pole—AC-1/400V
(time interval between two loading cycles: 15 minutes)
Short-time current

Breaking current

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

AC-1/400V

A
700

1

AC-1/400V

1

500
400

1

300

160
100

200

55
35

100

1
1

150

70

XTMC 6A
20 XTMC 9A

1

XTMC 6A
XTMC 9A

1

50
40

10
7
5
4
3
2

1

30

1

20

1

15

1

1
0.1

0.2 0.3

0.5 0.7

1

2

3

5

7

10

Seconds 2

Component lifespan (millions of operations)

3

5

7 10

20 30 50 70 100 200 300 500 700 900

Duration of load

1 min

3 min
10 min
5 min
15 min

1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-33

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

Dimensions

1

Non-Reversing Mini Contactor

Approximate Dimensions in mm [in.]

D

1
1

Non-Reversing Mini Contactor with Overload Relay

58
[2.28]

50
[1.97]

1
1

45
[1.77]

1

D1

XTMC

32
[1.26]
45
[1.77]

XTMCC

D

52 [2.05]

54 [2.13]

1

D1

83 [3.27]

86 [3.39]

1

Star-Delta Starter Combinations

1

106
49
[4.17] [1.93]

35
[1.38]

1

1

5.5 [.22]

M4

61
[2.40]
62.5
[2.46]

1

45
[1.77]

1
1
1

≥ 5 [.20]

XTMCXRSA, XTMCXVSA Mini Suppressors

1

1

58
[2.28]

52
[2.05]

XTMCXTSA Mini Sealable Shroud
180
[7.09]

83
[3.27]

43
[1.69]

108
[4.25]
58
[2.28]

1
1

45
[1.77]

45
[1.77]

69
[2.72]

1
1

Reversing Mini Contactor

1
1

XTMCXML Mechanical Interlock

61
[2.40]

58
[2.28]

108
[4.25]

1

90
[3.54]

63
[2.48]

1
90
[3.54]

1

94
[3.70]
58
[2.28]

1
1

90
[3.54]

1
V5-T1-34

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

94
[3.70]

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Contents

XT Family of Contactors

Description

Page

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters
Product Identification . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-3
V5-T1-18
V5-T1-36
V5-T1-38
V5-T1-39
V5-T1-65
V5-T1-78
V5-T1-109
V5-T1-114

An Eaton
Green Solution

Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-128
V5-T1-141
V5-T1-157
V5-T1-193
V5-T1-216
V5-T1-229

1
1
1
1
1
1
1
1
1
1
1

Contactors and Starters
Product Description

Application Description

The Eaton XT contactors
and starters includes nonreversing and reversing
contactors, overload relays
and a variety of related
accessories. Because XT
meets IEC, UL®, CSA® and
CE standards, it is the perfect
product solution for IEC
applications all over the
world. The compact, space
saving and easy to install
XT line of IEC contactors and
starters is the efficient and
effective solution for
customer applications from
7A to 2450A.

The XT line of IEC power
control was engineered to
provide highly effective
control and protection for a
variety of loads, including
motors, compressors,
pumps, resistive, capacitor
banks, isolation, and others.
XT also includes IEC ratings
for lighting applications as
well.
XT contactors can be used in
safety applications according
to EN 954-1, EN ISO 13849-1
and IEC 62061 up to Category
4, Pl e and SIL 3. Information
concerning safety related
characteristics (B10 and B10d
values) is available online. The
auxiliary contact modules and
built-in auxiliary contacts
meet IEC EN 60947-5-1
Annex L (positively driven)
and IEC EN 60947-4-1
Annex F (mirror contacts).

Features and Benefits
●

●

●

●

●

●

●

●

●

AC control from
12V to 600V 50/60 Hz
DC control from
12V to 220V
Available with screw or
spring cage terminals
Reversing or non-reversing
contactors and starters
AC-3 contactor ratings to
1000A and AC-1 contactor
ratings to 2000A
Non-reversing starters
to 650A
Panel or DIN rail mounting
to 65A
IP20 finger and back-ofhand proof
Large ambient temperature
range, –25 to 50°C
[–13 to 122°F]

●

●

●

●

●

●

●

AC and DC controlled
contactors in the same
compact frame
Low power consumption
AC and DC coils
Built-in NO or NC auxiliary
contacts to 32A
Plug-in accessories for
reduced installation time
Coil replacement on
Frames C–N (18–820A)
Contact replacement on
Frames D–N (40 –820A)
Integrated suppressor
7–150A DC operated
contactors and 185–2000A
AC and DC operated
contactors

Standards and Certifications
●
●
●
●
●
●

IEC EN 60947
CE approved
UL
CSA
ATEX
RoHS

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Note: For Type 2 Coordination,
see Page V5-T1-230.

Reference
Refer to Volume 10—Enclosed Control, CA08100012E,
Tab 3, section 3.1 for additional Product information on
IEC Non-Metallic Enclosed Contactors and Starters.

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-35

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Product Identification
XTCE007B to XTCE170G (7 to 170A) Contactors

1

1

1

4

4

1

4

1

1
1

1
1
1
1
1

2

3

1
1
1

3
4
4

3
4

2

1

3

1
1
4

1

4
4

1
1
1
1
1
1
1
1
1
1

Notes
1 Contactor up to 170A AC-3 (see Page V5-T1-39)
AC: 12–600V, 50, 60, 50/60 Hz
0.8–1.1 x Uc)
DC: 12–250V
XTCE…B_ (7–15A): 0.8–1.1 x Uc
XTCE…C_–XTCE…G_(18–150A): 0.7–1.2 x Uc
24V: 0.7–1.3 x Uc at 40°C without additional auxiliary contacts
Coils for special voltages
“Safe Isolation” to IEC 536 between coil and contacts
2 Suppressors (see Page V5-T1-71)
RC suppressor
Varistor suppressor
Free-wheel diode suppressor
3 Overload Relays (see Page V5-T1-130)
Can be mounted directly
Separate mounting, possible
Protection of EEx e-motors
4 Auxiliary Contact Modules (see Page V5-T1-24)
Two-pole, plug-in type
Four-pole, plug-in type
Overlapping contacts
Two-pole, side-mounting

1
1
1
V5-T1-36

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

XTCE185–XTCE20 Contactors

1
1
1
1

2
3

1
1
1

1

1
1
7

1
1
1
4

1
1
1
1
1

5

1
6

1
1

Notes
1 XTCE Contactors for 185–2000A
(see Page V5-T1-46)
Multi-voltage coils:
24–48 Vdc
48–110 Vac/Vdc
110–250 Vac/Vdc
250–500 Vac
0.7–1.15 x Uc
Actuation options:
Directly
From the PLC
With low-consumption contact
XTCS Contactors for 185–570A AC-3
(see Page V5-T1-42)
Control voltages:
110–120V 50/60 Hz
220–240V 50/60 Hz
Conventional operation

2

3

4

Cable Terminal Block
(see Page V5-T1-97)
One or two conductors per phase
Round and flat conductor connectable
Finger-proof
Flat Strip Conductor Terminals
(see Page V5-T1-97)
One or two strips per phase
Control circuit terminal
Cover for fingerproofing
Mechanical Interlock
(see Page V5-T1-73)
Fits between contactors

5

6

7

1

Overload Relays
(see Page V5-T1-130)
Can be mounted directly
Separate mounting, possible
Protection of EEx e-motors
PTB certificate
Terminal Shroud
(see Page V5-T1-75)
Finger-proof
Auxiliary Contact Modules
(see Page V5-T1-24)
Two-pole, side-mounting

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-37

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

Catalog Number Selection

1

XT IEC Contactors and Starters

XT CE C 007 B 01 AD P16

1
1
1
1
1
1
1

Designation
XT = XT line of IEC control

CE
CS
CF
CR
CC
AE
AS
AR

=
=
=
=
=
=
=
=

Type
Three-pole FVNR IEC contactor
Three-pole FVNR S Series IEC contactor
Four-pole FVNR IEC contactor
Three-pole FVR IEC contactor
IEC capacitor contactor
FVNR IEC starter
FVNR S-Series IEC starter
FVR IEC starter

1

007 = 7A
009 = 9A
012 = 12A
015 = 15A
018 = 18A
025 = 25A
032 = 32A
040 = 40A
050 = 50A
065 = 65A
072 = 72A

1
1
1
1

Terminations
Blank = Screw terminals
(6–65A);
5 mm (80–150A);
no lugs
(185–2000A)
C
= Spring cage
terminals consult
local sales office
for availability

Current Ratings, AC-3
080 = 80A
570 = 570A
095 = 95A
580 = 580A
115= 115A
650 = 650A
150 = 150A
750 = 750A
170 = 170A
820 = 820A
185 = 185A
C10 = 1000A
225 = 225A
C14 = 1400A, AC-1
250 = 250A
C16 = 1600A, AC-3
300 = 300A
C20 = 2000A, AC-1
400 = 400A
500 = 500A

Coil Codes
See Page
V5-T1-53.

Built-In Auxiliary Contact
01 = 1NC
10 = 1NO
00 = 0NO–0NC
S1 = 1NO–1NC
side-mount auxiliary
11 = 1NO–1NC
top-mount auxiliary
22 = 2NO–2NC

B
C
D
F
G
H

=
=
=
=
=
=

Frame Size Designation
45 mm
L = 140 mm
45 mm
M = 160 mm
55 mm
N = 250 mm
90 mm
P = 260 mm
90 mm
R = 515 mm
140 mm

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-38

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XTAE, XTAS and XTAR Starters Only—
Maximum Overload Relay
XTOB Maximum Overload Rating
Frame B
Frame D
P16 = 0.1–0.16A
010 = 6–10A
P24 = 0.16–0.24A
016 = 10–16A
P40 = 0.24–0.4A
024 = 16–24A
P60 = 0.4–0.6A
040 = 24–40A
001 = 0.6–1A
057 = 40–57A
1P6 = 1.0–1.6A
065 = 50–65A
2P4 = 1.6–2.4A
075 = 65–75A
004 = 2.4–4A
006 = 4–6A
Frame F
010 = 6–10A
035 = 25–35A
012 = 9–12A
050 = 35–50A
016 = 12–16A
070 = 50–70A
100 = 70–100A
Frame C
P16 = 0.1–0.16A
P24 = 0.16–0.24A
P40 = 0.24–0.4A
P60 = 0.4–0.6A
001 = 0.6–1A
1P6 = 1.0–1.6A
2P4 = 1.6–2.4A
004 = 2.4–4A
006 = 4–6A
010 = 6–10A
016 = 10–16A
024 = 16–24A
032 = 24–32A

Frame G
035 = 25–35A
050 = 35–50A
070 = 50–70A
100 = 70–100A
125 = 95–125A
150 = 120–150A
175 = 145–175A

Frame L
070 = 50–70A
100 = 70–100A
125 = 95–125A
160 = 120–160A
220 = 160–220A
250 = 200–250A
XTOE Maximum Overload Rating
Standard
Ground Fault
Type Suffix
Type Suffix
Frame B
5E1P6
5G1P6
0.33–1.65A
5E005
5G005
1–5A
5E020
5G020
4–20A
Frame C
5E1P6
5G1P6
0.33–1.65A
5E005
5G005
1–5A
5E020
5G020
4–20A
5E045
5G045
9–45A
Frame D
5E045
5G045
9–45A
5E100
5G100
20–100A
Frame F, G
5E100
5G100
20–100A
Frame G, H
5E175
5G175
35–175A

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Product Selection

1

Full Voltage, Non-Reversing Contactors
Frame B

1

Three-Pole Contactors, Frame B—UL/CSA Ratings
UL General Purpose
Ampere Rating

Single-Phase hp Ratings

Three-Phase hp Ratings

115V

200V

230V

200V

230V

460V

575V

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

20

1/4

3/4

1

1-1/2

2

3

5

1NO

XTCE007B10_

20

1/4

3/4

1

1-1/2

2

3

5

1NC

XTCE007B01_

20

1/2

1

1-1/2

3

3

5

7-1/2

1NO

XTCE009B10_

20

1/2

1

1-1/2

3

3

5

7-1/2

1NC

XTCE009B01_

3

10

1NO

XTCE012B10_

20

1

2

2

3

3

10

20

1

2

2

3

3

10 3

10

1NC

XTCE012B01_

3

10

1NO

XTCE015B10_

10

1NC

XTCE015B01_

20

1

2

3

5

5

10

20

1

2

3

5

5

10 3

1
1
1
1
1
1
1

Three-Pole Contactors, Frame B—IEC Ratings
AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

7

22

2.2

3

4

7

22

2.2

3

4

9

22

2.5

4

5.5

9

22

2.5

4

5.5

12

22

3.5

5.5

12

22

3.5

5.5

15.5

22

4

15.5

22

4

660/690V

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

3.5

1NO

XTCE007B10_

3.5

1NC

XTCE007B01_

4.5

1NO

XTCE009B10_

4.5

1NC

XTCE009B01_

7

6.5

1NO

XTCE012B10_

7

6.5

1NC

XTCE012B01_

7.5

8

7

1NO

XTCE015B10_

7.5

8

7

1NC

XTCE015B01_

Notes
The 7–32A XTCE contactors have positively driven contacts between the integrated auxiliary contact and
the auxiliary contact module as well as within the auxiliary contact modules.

2

3

1
1
1
1
1
1
1

DC operated contactors (Frames B–G, 7–150A) have a built-in suppressor circuit.
1

1

1

Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.
For spring cage terminals, insert C after the fourth digit of the catalog number. Example: XTCEC007B10A.
For 7–12A XTCEC contactors, the power, auxiliary and coil terminals are spring cage.
For 18–32A XTCEC contactors, the auxiliary and coil terminals are spring cage.
For 40–150A XTCEC contactors, the coil terminals only are spring cage.
For electrical life contactor application data. See Page V5-T1-45.

1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-39

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame C

IEC Contactors and Starters
XT IEC Power Control

Three-Pole Contactors, Frame C—UL/CSA Ratings
UL General Purpose
Ampere Rating

Single-Phase hp Ratings
115V
200V
230V

Three-Phase hp Ratings
200V
230V
460V

575V

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

40

2

2

3

5

5

10

15

1NO

XTCE018C10_

1

40

2

2

3

5

5

10

15

1NC

XTCE018C01_

40

2

3

5

7-1/2

10

15

20

1NO

XTCE025C10_

1

40

2

3

5

7-1/2

10

15

20

1NC

XTCE025C01_

40

3

5

5

10

10

20

25

1NO

XTCE032C10_

1

40

3

5

5

10

10

20

25

1NC

XTCE032C01_

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

1

1

Three-Pole Contactors, Frame C—IEC Ratings

1

AC-3
Ie (A)

1

18

40

5

7.5

10

11

1NO

XTCE018C10_

18

40

5

7.5

10

11

1NC

XTCE018C01_

1

25

45

7.5

11

14.5

14

1NO

XTCE025C10_

25

45

7.5

11

14.5

14

1NC

XTCE025C01_

1

32

45

10

15

18

17

1NO

XTCE032C10_

32

45

10

15

18

17

1NC

XTCE032C01_

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

AC-1 (40°C)
Ie = Ith (A)

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz
220/230V
380/400V
415V
660/690V

1
1

Frame D

Three-Pole Contactors, Frame D—UL/CSA Ratings
UL General Purpose
Ampere Rating

Single-Phase hp Ratings

Three-Phase hp Ratings

115V

200V

200V

63

3

5

7-1/2

10

15

30

40

—

XTCE040D00_

1

63

3

5

7-1/2

10

15

30

40

1NO-1NC

XTCE040DS1_

80

3

7-1/2

10

15

20

40

50

—

XTCE050D00_

1

80

3

7-1/2

10

15

20

40

50

1NO-1NC

XTCE050DS1_

88

5

10

15

20

25

50

60

—

XTCE065D00_

88

5

10

15

20

25

50

60

1NO-1NC

XTCE065DS1_

88

5

10

15

20

25

50

60

—

XTCE072D00_

88

5

10

15

20

25

50

60

1NO-1NC

XTCE072DS1_

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

1

1
1
1

230V

230V

460V

575V

Three-Pole Contactors, Frame D—IEC Ratings

1

AC-3
Ie (A)

1

AC-1 (40°C)
Ie = Ith (A)

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

660/690V

40

60

12.5

18.5

24

23

—

XTCE040D00_

1

40

60

12.5

18.5

24

23

1NO-1NC

XTCE040DS1_

50

80

15.5

22

30

30

—

XTCE050D00_

1

50

80

15.5

22

30

30

1NO-1NC

XTCE050DS1_

65

98

20

30

39

35

—

XTCE065D00_

1

65

98

20

30

39

35

1NO-1NC

XTCE065DS1_

72

98

22

37

41

35

—

XTCE072D00_

72

98

22

37

41

35

1NO-1NC

XTCE072DS1_

1
1

Notes
The 7–32A XTCE contactors have positively driven contacts between the integrated auxiliary contact and
the auxiliary contact module as well as within the auxiliary contact modules.

1

The 40–65A XTCE contactors have positively driven contacts within the auxiliary contact module.
Six auxiliary contacts are possible with a combination of side-mounted and front-mount auxiliary contacts.

1

DC operated contactors (Frames B–G, 7–150A) have a built-in suppressor circuit.
1

1

2

1

Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.
For spring cage terminals, insert C after the fourth digit of the catalog number. Example: XTCEC007B10A.
For 7–12A XTCEC contactors, the power, auxiliary and coil terminals are spring cage.
For 18–32A XTCEC contactors, the auxiliary and coil terminals are spring cage.
For 40–150A XTCEC contactors, the coil terminals only are spring cage.

1
V5-T1-40

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

Frame F

1.1

Three-Pole Contactors, Frame F—UL/CSA Ratings
UL General Purpose
Ampere Rating

Single-Phase hp Ratings

Three-Phase hp Ratings

115V

200V

230V

200V

230V

460V

125

7-1/2

15

15

25

30

60

575V

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

75

—

XTCE080F00_

125

7-1/2

15

15

25

30

60

75

1NO-1NC

XTCE080FS1_

125

7-1/2

15

15

25

40

75

100

—

XTCE095F00_

125

7-1/2

15

15

25

40

75

100

1NO-1NC

XTCE095FS1_

1
1
1
1
1

Three-Pole Contactors, Frame F—IEC Ratings

Frame G

AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

660/690V

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

80

110

25

37

48

63

—

XTCE080F00_

80

110

25

37

48

63

1NO-1NC

XTCE080FS1_

95

130

30

45

57

75

—

XTCE095F00_

95

130

30

45

57

75

1NO-1NC

XTCE095FS1_

1
1
1
1
1

Three-Pole Contactors, Frame G—UL/CSA Ratings
UL General Purpose
Ampere Rating

Single-Phase hp Ratings

Three-Phase hp Ratings

115V

200V

230V

200V

230V

460V

575V

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

160

10

25

25

40

50

100

100

—

XTCE115G00_

160

10

25

25

40

50

100

100

1NO-1NC

XTCE115GS1_

180

10

25

30

40

60

125

125

—

XTCE150G00_

180

10

25

30

40

60

125

125

1NO-1NC

XTCE150GS1_

180

10

25

30

40

60

125

125

—

XTCE170G00_

180

10

25

30

40

60

125

125

1NO-1NC

XTCE170GS1_

1
1
1
1
1
1

Three-Pole Contactors, Frame G—IEC Ratings
AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

115

160

37

55

70

115

160

37

55

150

190

48

75

150

190

48

170

190

52

170

190

52

660/690V

Auxiliary
Contacts

Screw Terminal
Catalog Number 12

90

—

XTCE115G00_

70

90

1NO-1NC

XTCE115GS1_

91

96

—

XTCE150G00_

75

91

96

1NO-1NC

XTCE150GS1_

90

100

96

—

XTCE170G00_

90

100

96

1NO-1NC

XTCE170GS1_

1
1
1
1

DC operated contactors (Frames B–G, 7–150A) have a built-in suppressor circuit.
2

1

1

Notes
The 40–65A XTCE contactors have positively driven contacts within the auxiliary contact module.
Six auxiliary contacts are possible with a combination of side-mounted and front-mount auxiliary contacts.
1

1

Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.
For spring cage terminals, insert C after the fourth digit of the catalog number. Example: XTCEC007B10A.
For 7–12A XTCEC contactors, the power, auxiliary and coil terminals are spring cage.
For 18–32A XTCEC contactors, the auxiliary and coil terminals are spring cage.
For 40–150A XTCEC contactors, the coil terminals only are spring cage.

1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-41

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame H

1
1

IEC Contactors and Starters
XT IEC Power Control

Three-Pole Contactors, Frame H (Electronic Coil)—UL/CSA Ratings
UL General Purpose
Ampere Rating

Three-Phase hp Ratings
200V
240V

480V

600V

Auxiliary
Contacts

Catalog
Number 12

250

50

60

125

150

2NO-2NC

XTCE185H22_

250

60

75

150

200

2NO-2NC

XTCE225H22_

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz

1
1

Three-Pole Contactors, Frame H (Electronic Coil)—IEC Ratings

1

AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

220/230V

380/400V

660/690V 3

1000V 3

Auxiliary
Contacts

Catalog
Number 12

1

185

337

55

90

140

108

2NO-2NC

XTCE185H22_

225

386

70

110

215

108

2NO-2NC

XTCE225H22_

460V

575V

Auxiliary
Contacts

Catalog
Number 12

1
1

Frame L

Three-Pole Contactors, Frame L—UL/CSA Ratings
UL General Purpose
Ampere Rating

1

Three-Phase hp Ratings
200V
230V

Standard Coil (110/120V, 230/240 Vac Coil Only)

1

300

75

100

200

250

2NO-2NC

XTCS250L22_

1

350

100

125

250

300

2NO-2NC

XTCS300L22_

1

300

75

100

200

250

2NO-2NC

XTCE250L22_

350

100

125

250

300

2NO-2NC

XTCE300L22_

Auxiliary
Contacts

Catalog
Number 12

Electronic Coil

1

Three-Pole Contactors, Frame L—IEC Ratings

1

AC-3
Ie (A)

1

AC-1 (40°C)
Ie = Ith (A)

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz
220/230V
380/400V
660/690V 3
1000V 3

Standard Coil (110/120V, 230/240 Vac Coil Only)

1

250

429

75

132

240

108

2NO-2NC

XTCS250L22_

300

490

90

160

195

132

2NO-2NC

XTCS300L22_

250

429

75

132

240

108

2NO-2NC

XTCE250L22_

300

490

90

160

195

132

2NO-2NC

XTCE300L22_

Electronic Coil

1
1

Notes
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53. Terminals not included. See Page V5-T1-75 for terminal accessories.
2 Does not include lugs.
3 For 185–500A contactors at 660/690V or 1000V: Do not reverse directly.

1
1
1
1
1
1
1
1
1
1
1
V5-T1-42

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

Frame M

1.1

Three-Pole Contactors, Frame M—UL/CSA Ratings
UL General Purpose
Ampere Rating

Three-Phase hp Ratings
200V
230V

460V

575V

Auxiliary
Contacts

Catalog
Number 12

Standard Coil (110/120V, 230/240 Vac Coil Only)

1
1
1

450

125

150

300

400

2NO-2NC

XTCS400M22_

550

150

200

400

500

2NO-2NC

XTCS500M22_

550

150

200

400

500

2NO-2NC

XTCS570M22_

1

450

125

150

300

400

2NO-2NC

XTCE400M22_

1

550

150

200

400

500

2NO-2NC

XTCE500M22_

550

150

200

400

500

2NO-2NC

XTCE570M22_

Electronic Coil

1

Three-Pole Contactors, Frame M—IEC Ratings
AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

1

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz
220/230V
380/400V
415V
660/690V 3 1000V 3

Auxiliary
Contacts

Catalog
Number 12

Standard Coil (110/120V, 230/240 Vac Coil Only)

1
1

400

612

125

200

240

344

132

2NO-2NC

XTCS400M22_

500

857

155

250

300

344

132

2NO-2NC

XTCS500M22_

580

980

155

315

350

344

132

2NO-2NC

XTCS570M22_

1
1

Electronic Coil
400

612

125

200

240

344

132

2NO-2NC

XTCE400M22_

500

857

155

250

300

344

132

2NO-2NC

XTCE500M22_

580

980

155

315

350

344

132

2NO-2NC

XTCE570M22_

1
1

Notes
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53. Terminals not included. See Page V5-T1-75 for terminal accessories.
2 Does not include lugs.
3 For 185–500A contactors at 660/690V or 1000V: Do not reverse directly.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-43

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame N

IEC Contactors and Starters
XT IEC Power Control

Three-Pole Contactors, Frame N (Electronic Coil)—UL/CSA Ratings
UL General Purpose
Ampere Rating

1
1
1
1

Three-Phase hp Ratings
200V

230V

460V

575V

Auxiliary
Contacts

Catalog Number 12

630

200

200

400

600

2NO-2NC

XTCE580N22_ 3

700

200

250

500

600

2NO-2NC

XTCE650N22_ 3

800

250

300

600

700

2NO-2NC

XTCE750N22_ 3

850

290

350

700

860

2NO-2NC

XTCE820N22_ 3

1100

350

420

850

980

2NO-2NC

XTCEC10N22_ 3

1

Three-Pole Contactors, Frame N (Electronic Coil)—IEC Ratings

1

AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

220/230V

380/400V

415V

660/690V 4

1000V 4

Auxiliary
Contacts

Catalog Number 12

1

580

980

185

315

348

560

600

2NO-2NC

XTCE580N22_ 3

650

1041

205

355

390

630

600

2NO-2NC

XTCE650N22_ 3

1

750

1102

240

400

455

720

800

2NO-2NC

XTCE750N22_ 3

820

1225

260

450

500

750

800

2NO-2NC

XTCE820N22_ 3

1000

1225

315

560

610

1000

1000

2NO-2NC

XTCEC10N22_ 3

1

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz

1
1

Frame P

1

Three-Pole Contactors, Frame P (Electronic Coil)—UL/CSA Ratings
UL General Purpose
Ampere Rating

Three-Phase hp Ratings
200V

230V

460V

575V

Auxiliary
Contacts

Catalog Number 12

1400

—

—

—

—

2NO-2NC

XTCEC14P22_ 3

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz

1
1

Three-Pole Contactors, Frame P (Electronic Coil)—IEC Ratings

1
1
1

Frame R

AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

220/230V

380/400V

415V

660/690V 4

1000V 4

Auxiliary
Contacts

Catalog Number 12

—

1714

—

—

—

—

—

2NO-2NC

XTCEC14P22_ 3

Catalog Number 12

Three-Pole Contactors, Frame R (Electronic Coil)—UL/CSA Ratings
UL General Purpose
Ampere Rating

1
1

Three-Phase hp Ratings
200V

230V

460V

575V

Auxiliary
Contacts

1600

560

640

1200

1300

2NO-2NC

XTCEC16R22_ 3

2000

—

—

—

—

2NO-2NC

XTCEC20R22_ 3

Maximum kW Ratings AC-3/Three-Phase Motors 50–60 Hz

1
Three-Pole Contactors, Frame R (Electronic Coil)—IEC Ratings

1
1
1
1

AC-3
Ie (A)

AC-1 (40°C)
Ie = Ith (A)

220/230V

380/400V

415V

660/690V 4

1000V 4

Auxiliary
Contacts

Catalog Number 12

1600

2200

500

900

900

1600

1700

2NO-2NC

XTCEC16R22_ 3

—

2450

—

—

—

—

—

2NO-2NC

XTCEC20R22_ 3

Notes
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53. Terminals not included. See Page V5-T1-75 for terminal accessories.
2 Does not include lugs.
3 When operating the 580–2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be
removed when performing a high-voltage test—see Pub51204, Pub51209.
4 For 185–500A contactors at 660/690V or 1000V: do not reverse directly.

1
1
1
1
1
V5-T1-44

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

Contactor
Application Data 12

1.1

Full Voltage Non-Reversing Three-Pole Contactors—
Contact Sequence (Circuit Symbols)—Standard Offering

Catalog
Prefix

Electrical Life (Operations)
for 10 hp, 480V (14.2A)
Applications

XTCE012B

1 million

XTCE015B

1.2 million

XTCE018C

2 million

Contactor
Frame

Auxiliary
Contacts

B–C

1NO

1

Contact Sequence

A1 1 3 5 13

1

A2 2 4 6 14
B–C

1NC

D–G

—

1

A1 1 3 5 21
A2 2 4 6 22

1

A1 1 3 5

1

A2 2 4 6
L–R

1

2NO-2NC

1
1
1

Four-Pole Contactors with Screw Terminals—Maximum UL/CSA Motor Ratings
Single-Phase hp Ratings

Three-Phase hp Ratings

115V

230V

200V

230V

460V

575V

Auxiliary
Contacts

1

2

3

3

10

10

—

XTCF020B00_

—

—

7.5

7.5

10

15

1NO

XTCF032C10_

—

—

7.5

10

15

20

1NO

XTCF045C10_

—

—

10

15

30

40

—

XTCF063D00_

—

—

15

20

40

50

—

XTCF080D00_

—

—

25

30

60

75

—

XTCF125G00_

—

—

25

40

75

100

—

XTCF160G00_

—

—

40

50

100

125

—

XTCF200G00_

Contact
Sequence

Catalog Number 3

1
1
1
1
1
1
1
1

Four-Pole Contactors with Screw Terminals—Maximum IEC Ratings
AC-3
I e (A)

AC-1
(40°C)

Three-Phase hp Ratings
200V

230V

460V

575V

Auxiliary
Contacts

12

22

3

3

10

10

—

XTCF020B00_

12

22

3.5

5.5

7

6.5

—

XTCF020B00_

18

32

5

7.5

10

11

1NO

XTCF032C10_

25

45

7.5

11

14.5

14

1NO

XTCF045C10_

Contact
Sequence

Catalog Number 3

40

63

12.5

18.5

24

23

—

XTCF063D00_

50

80

15.5

22

30

30

—

XTCF080D00_

80

125

25

37

48

63

—

XTCF125G00_

95

160

30

45

57

75

—

XTCF160G00_

115

200

37

55

70

90

—

XTCF200G00_

1
1
1
1
1
1
1
1
1

Notes
1 See Page V5-T1-111 for electrical life curves.
2 AC and DC operated contactors have a built-in suppressor circuit (Frames L–R, 185–2000A).
3 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.

1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-45

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Switching of DC Currents 1
Description

Single-Pole

Two-Pole

XTCF020B–XTCF200G
>60 Vdc

1
1

Controlling XTCS and XTCE Contactors Frames L–R (185–2000A)

1

Description

XTCS250L–XTCS500M,
XTCE_H

XTCEC16R, XTCEC20R

XTCE250L–XTCEC14P

1

Conventional
A1/A2 are applied to voltage in the usual manner.

(+) L1
(–) N

(+) L1
(–) N

(+) L1
(–) N

1
1
1
1

Direct from the PLC
A 24V output from the PLC can be connected directly to
connections A3/A4.

b

1

From Low-Consumption Command Devices
Command devices, which can only be subject to minimal loads
such as circuit board relays, control circuit devices or position
switches can be connected directly to A10/A11.

b

A10

A2

A10

A2

A10

A2

A11

A1

A11

A1

A11

A1

A3

TY

A3

A3

A4

TX

A4

A4

—

(+) L1
(–) N

(+) L1
(–) N
b

1
1

b

—

1

b

A10

A2

A10

A2

A11

A1

A11

A1

TY

A3

TX

A4

A3
A4

24V
GND

24V
GND

(+) L1
(–) N

(+) L1
(–) N

c

b

A10

A2

A11

A1

TY

A3

A3

TX

A4

A4

c

A10

A2

A11

A1

1
1
1

Notes
1 When necessary, cable to be supplied by customer.
2 Standstill in an emergency (emergency-stop).
3 Command device connection.

1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-46

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

b

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Full Voltage, Reversing Contactors
Frame B

1

Contactors with Screw Terminals, Frame B—Maximum UL/CSA Ratings
Single-Phase hp Ratings

Three-Phase hp Ratings

1

Spare Auxiliary Contacts

115V

230V

200V

230V

460V

575V

K1M

K2M

1/4

1

1-1/2

2

3

5

63
64

63
64

XTCR007B21_

1/2

1-1/2

2

3

5

7-1/2

63
64

63
64

XTCR009B21_

1/2

2

3

3

7-1/2

10

63
64

63
64

XTCR012B21_

Catalog Number

1

1
1
1
1
1

Contactors with Screw Terminals, Frame B—Maximum IEC Ratings

1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz

Spare Auxiliary Contacts

220/230V

380/400V

415V

660/690V

K1M

K2M

7

2.2

3

4

3.5

63
64

63
64

XTCR007B21_

9

2.5

4

5.5

4.5

63
64

63
64

XTCR009B21_

12

3.5

5.5

7

6.5

63
64

63
64

XTCR012B21_

Catalog Number

1

1
1
1
1
1

Frame C

1

Contactors with Screw Terminals, Frame C—Maximum UL/CSA Ratings
Single-Phase hp Ratings

Three-Phase hp Ratings

Spare Auxiliary Contacts

115V

230V

200V

230V

460V

575V

2

3

5

5

10

15

63
64

63
64

XTCR018C21_

2

5

7-1/2

7-1/2

15

20

63
64

63
64

XTCR025C21_

1

3

5

10

10

20

25

63
64

63
64

XTCR032C21_

1

K1M

K2M

Catalog Number 1

1
1

1
1

Contactors with Screw Terminals, Frame C—Maximum IEC Ratings
AC-3
I e (A)

Three-Phase Motors 50–60 Hz

Spare Auxiliary Contacts

220/230V

380/400V

415V

660/690V

18

5

7.5

8

25

7.5

11

32

10

15

Catalog Number 1

1

K1M

K2M

11

63
64

63
64

XTCR018C21_

1

14.5

14

63
64

63
64

XTCR025C21_

1

18

17

63
64

63
64

XTCR032C21_

1
1

Note
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-47

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame D

IEC Contactors and Starters
XT IEC Power Control

Contactors with Screw Terminals, Frame D—Maximum UL/CSA Ratings
Single-Phase hp Ratings

Three-Phase hp Ratings

1

115V

230V

200V

230V

460V

575V

K1M

3

7-1/2

10

15

30

40

1

3

10

15

20

40

50

5

15

20

25

50

60

1

Spare Auxiliary Contacts
K2M

Catalog Number 1

—

—

XTCR040D11_

—

—

XTCR050D11_

—

—

XTCR065D11_

1

Contactors with Screw Terminals, Frame D—Maximum IEC Ratings

1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V

380/400V

1

40

12.5

18.5

24

23

—

—

XTCR040D11_

50

15.5

22

30

30

—

—

XTCR050D11_

1

65

20

30

39

35

—

—

XTCR065D11_

1
1

Frame F

1
1

Spare Auxiliary Contacts
415V

660/690V

K1M

Catalog Number 1

Contactors with Screw Terminals, Frame F—Maximum UL/CSA Ratings
Single-Phase hp Ratings

Three-Phase hp Ratings

115V

200V

230V

230V

Spare Auxiliary Contacts
460V

575V

K1M

K2M

Catalog Number 1

7-1/2

15

25

30

60

75

—

—

XTCR080F11_

7-1/2

15

25

40

75

100

—

—

XTCR095F11_

1

Contactors with Screw Terminals, Frame F—Maximum IEC Ratings

1

AC-3
I e (A)

1

K2M

Three-Phase Motors 50–60 Hz
220/230V

Spare Auxiliary Contacts

380/400V

415V

660/690V

K1M

K2M

Catalog Number 1

80

25

37

48

63

—

—

XTCR080F11_

95

30

45

57

75

—

—

XTCR095F11_

1
1

Frame G

1
1

Contactors with Screw Terminals, Frame G—Maximum UL/CSA Ratings
Single-Phase hp Ratings

Three-Phase hp Ratings

115V

230V

200V

230V

460V

575V

K1M

Spare Auxiliary Contacts
K2M

Catalog Number 1

10

25

40

50

100

100

—

—

XTCR115G11_

15

30

40

60

100

100

—

—

XTCR150G11_

1
Contactors with Screw Terminals, Frame G—Maximum IEC Ratings

1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

660/690V

K1M

K2M

Catalog Number 1

115

37

55

70

90

—

—

XTCR115G11_

1

150

48

75

91

96

—

—

XTCR150G11_

1

Note
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.

1

Spare Auxiliary Contacts

1
1
1
1
1
1
V5-T1-48

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

XTCR Reversing Contactor Components

1

Quantity

Frame

B

C

D

F

G

2

Contactor

XTCE…B01_

XTCE…C01_

XTCE…D00_

XTCE…F00_

XTCE…G00_

2

Auxiliary contact

XTCEXFAC20

XTCEXFAC20

XTCEXFBG11

XTCEXFBG11

XTCEXFBG11

1

Mechanical interlock

XTCEXMLB

XTCEXMLC

XTCEXMLD

XTCEXMLG

XTCEXMLG

1

Reversing link kit

XTCEXRLB

XTCEXRLC

XTCEXRLD

XTCEXRLG

XTCEXRLG

1
1
1
1

Magnet Coil Suffix
Coil Voltage

Suffix Code

Frames A–B

Coil Voltage

Suffix Code

Frames C–F

Coil Voltage

Suffix Code

Frame G

Coil Voltage

Suffix Code

1
1

Frames L–N

110V 50 Hz, 120V 60 Hz

A

110V 50 Hz, 120V 60 Hz

A

100–120V 50/60 Hz

A

110–250 Vdc 40–60 Hz

A

220V 50 Hz, 240V 60 Hz

B

220V 50 Hz, 240V 60 Hz

B

190–240V 50/60 Hz

B

250–500V 40–60 Hz

C

1

230V 50 Hz

F

230V 50 Hz

F

24V 50/60 Hz

T

48–110 Vdc 40–60 Hz

Y

24V 50/60 Hz

T

24V 50/60 Hz

T

24–27 Vdc

TD

24–48 Vdc

TD 1

24 Vdc

TD

24–27 Vdc

TD

480–500V 50/60 Hz

C

Frames L–M, S-Series

415V 50 Hz, 480V 60 Hz

C

415V 50 Hz, 480V 60 Hz

C

380–440V 50/60 Hz

L

110–120V 50/60 Hz

A

550V 50 Hz, 600V 60 Hz

D

550V 50 Hz, 600V 60 Hz

D

42–48V 50/60 Hz

W

220–240V 50/60 Hz

B

208V 60 Hz

E

208V 60 Hz

E

110–130 Vdc

AD

Frames P–R

190V 50 Hz, 220V 60 Hz

G

190V 50 Hz, 220V 60 Hz

G

200–240 Vdc

BD

230–250 Vdc 50–60 Hz

240V 50 Hz, 277V 60 Hz

H

240V 50 Hz, 277V 60 Hz

H

48–60 Vdc

WD

1

380V 50 Hz, 440V 60 Hz

L

380V 50 Hz, 440V 60 Hz

L

Frame H

400V 50 Hz

N

400V 50 Hz

N

100–120V 50/60 Hz

A

1

380V 60 Hz

P

380V 60 Hz

P

190–240V 50/60 Hz

B

12V 50/60 Hz

R

12V 50/60 Hz

R

480–500V 50/60 Hz

C

42V 50 Hz, 48V 60 Hz

W

42V 50 Hz, 48V 60 Hz

W

380–440V 50/60 Hz

L

48V 50 Hz

Y

48V 50 Hz

Y

24V 50/60Hz

T

120 Vdc

AD

110–130 Vdc

AD

42–48V 50/60Hz

W

220 Vdc

BD

200–240 Vdc

BD

110–130 Vdc

AD

12 Vdc

RD

48–60 Vdc

WD

200–240 Vdc

BD

48 Vdc

WD

24–27 Vdc

TD

48–60 Vdc

WD

1
1
1

B

1
1
1
1
1
1

Note
1 Frames L–M only.

1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-49

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Full Voltage, Non-Reversing Starters, with Bimetallic or Electronic Overload
Frame B

Three-Pole Starters, Frame B—Maximum UL/CSA Ratings 1
Single-Phase hp Ratings

Three-Phase hp Ratings

1

115V

200V

230V

460V

575V

Auxiliary
Contacts

Catalog Number 23

1/4

1

1-1/2

2

3

5

1NO

XTAE007B10_ _

1

1/4

1

1-1/2

2

3

5

1NC

XTAE007B01_ _

1/2

1-1/2

3

3

5

7-1/2

1NO

XTAE009B10_ _

1

1/2

1-1/2

3

3

5

7-1/2

1NC

XTAE009B01_ _

1

2

3

3

10 4

10

1NO

XTAE012B10_ _

1

2

3

3

10 4

10

1NC

XTAE012B01_ _

1

3

5

5

10 4

10

1NO

XTAE015B10_ _

1

3

5

5

10 4

10

1NC

XTAE015B01_ _

1
1

230V

1
1

Three-Pole Starters, Frame B—Maximum IEC Ratings 1
Three-Phase Motors 50–60 Hz

AC-3
I e (A)

AC-1

220/230V

380/400V

415V

660/690V

Auxiliary
Contacts

Catalog Number 23

7

20

2.2

3

4

3.5

1NO

XTAE007B10_ _

7

20

2.2

3

4

3.5

1NC

XTAE007B01_ _

1

9

20

2.5

4

5.5

4.5

1NO

XTAE009B10_ _

9

20

2.5

4

5.5

4.5

1NC

XTAE009B01_ _

1

12

20

3.5

5.5

7

6.5

1NO

XTAE012B10_ _

12

20

3.5

5.5

7

6.5

1NC

XTAE012B01_ _

1

15.5

20

4

7.5

8

7

1NO

XTAE015B10_ _

15.5

20

4

7.5

8

7

1NC

XTAE015B01_ _

575V

Auxiliary
Contacts

Catalog Number 23

4

1
1

1
1

Frame C

1
1
1
1
1

Three-Pole Starters, Frame C—Maximum UL/CSA Ratings 1
Single-Phase hp Ratings

Three-Phase hp Ratings

115V

200V

230V

230V

460V

2

3

5

5

10

15

1NO

XTAE018C10_ _

2

3

5

5

10 4

15

1NC

XTAE018C01_ _

2

5

7-1/2

7-1/2

15

20

1NO

XTAE025C10_ _

2

5

7-1/2

7-1/2

15

20

1NC

XTAE025C01_ _

3

5

10

10

20

25

1NO

XTAE032C10_ _

3

5

10

10

20

25

1NC

XTAE032C01_ _

1

Three-Pole Starters, Frame C—Maximum IEC Ratings 1

1

AC-3
I e (A)

AC-1

220/230V

380/400V

415V

660/690V

Auxiliary
Contacts

Catalog Number 23

1

18

35

5

7.5

10

11

1NO

XTAE018C10_ _

18

35

5

7.5

10

11

1NC

XTAE018C01_ _

1

25

40

7.5

11

14.5

14

1NO

XTAE025C10_ _

25

40

7.5

11

14.5

14

1NC

XTAE025C01_ _

32

40

10

15

18

17

1NO

XTAE032C10_ _

32

40

10

15

18

17

1NC

XTAE032C01_ _

1
1

Three-Phase Motors 50–60 Hz

Notes
1 Products shown are with the bimetallic overload relay.
2 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.
3 Underscore (_) indicates overload relay suffix required. See Page V5-T1-54.
4 For electrical life contactor application data. See Page V5-T1-53.

1
1
1
V5-T1-50

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

Frame D

1.1

Three-Pole Starters, Frame D—Maximum UL/CSA Ratings 1
Single-Phase hp Ratings

Three-Phase hp Ratings

1

115V

230V

200V

230V

460V

575V

Auxiliary
Contacts

3

7-1/2

10

15

30

40

—

XTAE040D00_ _

3

10

15

20

40

50

—

XTAE050D00_ _

5

15

20

25

50

60

—

XTAE065D00_ _

Catalog Number

23

1
1
1

Three-Pole Starters, Frame D—Maximum IEC Ratings 1
AC-3
I e (A)

Frame F

Three-Phase Motors 50–60 Hz
AC-1

220/230V

380/400V

1

415V

660/690V

Auxiliary
Contacts

Catalog Number 23

40

50

12.5

18.5

24

23

—

XTAE040D00_ _

50

60

15.5

22

30

30

—

XTAE050D00_ _

65

72

20

30

39

35

—

XTAE065D00_ _

1
1
1
1

Three-Pole Starters, Frame F—Maximum UL/CSA Ratings 1
Single-Phase hp Ratings

Three-Phase hp Ratings

115V

230V

200V

230V

460V

575V

Auxiliary
Contacts

Catalog Number 23

7-1/2

15

25

30

60

75

—

XTAE080F00_ _

7-1/2

15

25

40

75

100

—

XTAE095F00_ _

1
1
1
1

Three-Pole Starters, Frame F—Maximum IEC Ratings 1
Three-Phase Motors 50–60 Hz

AC-3
I e (A)

AC-1

220/230V

380/400V

415V

660/690V

Auxiliary
Contacts

Catalog Number 23

80

110

25

37

48

63

—

XTAE080F00_ _

95

110

30

45

57

75

—

XTAE095F00_ _

1
1
1

Frame G

1

Three-Pole Starters, Frame G—Maximum UL/CSA Ratings 1
Single-Phase hp Ratings

Three-Phase hp Ratings

115V

230V

200V

230V

460V

10

25

40

50

15

30

40

60

575V

Auxiliary
Contacts

Catalog Number 23

100

125

—

XTAE115G00_ _

125

125

—

XTAE150G00_ _

1
1
1

Three-Pole Starters, Frame G—Maximum IEC Ratings 1
Three-Phase Motors 50–60 Hz

AC-3
I e (A)

AC-1

220/230V

380/400V

415V

115

160

37

55

70

150

160

48

75

91

1

660/690V

Auxiliary
Contacts

Catalog Number

105

—

XTAE115G00_ _

125

—

XTAE150G00_ _

23

Notes
1 Products shown are with the bimetallic overload relay.
2 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.
3 Underscore (_) indicates overload relay suffix required. See Page V5-T1-54.

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-51

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Full Voltage, Reversing Starters, with Bimetallic or Electronic Overload
Reversing Starters with Screw Terminals, Frame B—Maximum UL/CSA Ratings

1

Single-Phase hp Ratings

Three-Phase hp Ratings

1

115V

230V

200V

230V

460V

1/4

1

1-1/2

2

1

1/2

1-1/2

3

3

1

2

3

3

575V

Catalog Number 12

3

5

XTAR007B21_ _

5

7-1/2

XTAR009B21_ _

10

10

XTAR012B21_ _

1
1

Reversing Starters with Screw Terminals, Frame B—Maximum IEC Ratings

1

AC-3
I e (A)

1
1
1

Three-Phase Motors 50–60 Hz
660/690V

Catalog Number 12

220/230V

380/400V

415V

7

2.2

3

4

3.5

XTAR007B21_ _

9

2.5

4

5.5

4.5

XTAR009B21_ _

12

3.5

5.5

7

6.5

XTAR012B21_ _

Reversing Starters with Screw Terminals, Frame C—Maximum UL/CSA Ratings

1
1
1

Single-Phase hp Ratings

Three-Phase hp Ratings

115V

230V

200V

230V

460V

575V

Catalog Number 12

2

3

5

5

10

15

XTAR018C21_ _

2

5

7-1/2

7-1/2

15

20

XTAR025C21_ _

3

5

10

10

20

25

XTAR032C21_ _

1
Reversing Starters with Screw Terminals, Frame C—Maximum IEC Ratings

1

AC-3
I e (A)

1
1
1
1

Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

660/690V

Catalog Number 12

18

5

7.5

8

11

XTAR018C21_ _

25

7.5

11

14.5

14

XTAR025C21_ _

32

10

15

18

17

XTAR032C21_ _

Reversing Starters with Screw Terminals, Frame D—Maximum UL/CSA Ratings
Single-Phase hp Ratings

Three-Phase hp Ratings

115V

230V

200V

230V

460V

575V

Catalog Number 12

1

3

7-1/2

10

15

30

40

XTAR040D11_ _

3

10

15

20

40

50

XTAR050D11_ _

1

5

15

20

25

50

60

XTAR065D11_ _

1

1

Reversing Starters with Screw Terminals, Frame D—Maximum IEC Ratings

1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V

380/400V

40

12.5

18.5

1

50

15.5

22

65

20

30

39

1

Notes
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-53.
2 Underscore (_) indicates overload relay suffix required. See Page V5-T1-54.

1

1

660/690V

Catalog Number 12

24

23

XTAR040D11_ _

30

30

XTAR050D11_ _

35

XTAR065D11_ _

415V

1
1
V5-T1-52

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Starter Application Data 1
Catalog Prefix

AC-3

Electrical Life (Operations)

XTAE012B

12A

1 million

XTAE015B

15A

1.2 million

XTAE018C

18A

2 million

1
1
1
1

Magnet Coil Suffix
Coil Voltage

Suffix Code

Frames A–B

Coil Voltage

Suffix Code

Frames C–F

Coil Voltage

Suffix Code

Frame G

Coil Voltage

Suffix Code

1

A

1

Frames L–N

110V 50 Hz, 120V 60 Hz

A

110V 50 Hz, 120V 60 Hz

A

100–120V 50/60 Hz

A

110–250 Vdc 40–60 Hz

220V 50 Hz, 240V 60 Hz

B

220V 50 Hz, 240V 60 Hz

B

190–240V 50/60 Hz

B

250–500V 40–60 Hz

C

230V 50 Hz

F

230V 50 Hz

F

24V 50/60 Hz

T

48–110 Vdc 40–60 Hz

Y

24V 50/60 Hz

T

24V 50/60 Hz

T

24–27 Vdc

TD

24–48 Vdc

TD 2

1

24 Vdc

TD

24–27 Vdc

TD

480–500V 50/60 Hz

C

Frames L–M, S-Series

415V 50 Hz, 480V 60 Hz

C

415V 50 Hz, 480V 60 Hz

C

380–440V 50/60 Hz

L

110–120V 50/60 Hz

A

1

B

1

B

1

550V 50 Hz, 600V 60 Hz

D

550V 50 Hz, 600V 60 Hz

D

42–48V 50/60 Hz

W

220–240V 50/60 Hz

208V 60 Hz

E

208V 60 Hz

E

110–130 Vdc

AD

Frames P–R

190V 50 Hz, 220V 60 Hz

G

190V 50 Hz, 220V 60 Hz

G

200–240 Vdc

BD

230–250 Vdc 50–60 Hz

240V 50 Hz, 277V 60 Hz

H

240V 50 Hz, 277V 60 Hz

H

48–60 Vdc

WD

380V 50 Hz, 440V 60 Hz

L

380V 50 Hz, 440V 60 Hz

L

Frame H

400V 50 Hz

N

400V 50 Hz

N

100–120V 50/60 Hz

A

380V 60 Hz

P

380V 60 Hz

P

190–240V 50/60 Hz

B

12V 50/60 Hz

R

12V 50/60 Hz

R

480–500V 50/60 Hz

C

42V 50 Hz, 48V 60 Hz

W

42V 50 Hz, 48V 60 Hz

W

380–440V 50/60 Hz

L

48V 50 Hz

Y

48V 50 Hz

Y

24V 50/60Hz

T

120 Vdc

AD

110–130 Vdc

AD

42–48V 50/60Hz

W

220 Vdc

BD

200–240 Vdc

BD

110–130 Vdc

AD

12 Vdc

RD

48–60 Vdc

WD

200–240 Vdc

BD

48 Vdc

WD

24–27 Vdc

TD

48–60 Vdc

WD

1

1
1
1
1
1
1
1

Notes
1 See Page V5-T1-111 for electrical life curves.
2 Frames L–M only.

1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-53

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Bimetallic Overload Relay Suffix
Suffix Code

For Use with
Contactor
Ampere Range

Overload Relay
Catalog Number

0.1–0.16

P16

7–15A

XTOBP16BC1

0.16–0.24

P24

7–15A

XTOBP24BC1

0.24–0.4

P40

7–15A

1

0.4–0.6

P60

0.6–1

1

1–1.6

1
1
1

Motor Full
Load Amperes

Suffix Code

For Use with
Contactor
Ampere Range

Overload Relay
Catalog Number

6–10

010

40–72A

XTOB010DC1

10–16

016

40–72A

XTOB016DC1

XTOBP40BC1

16–24

024

40–72A

XTOB024DC1

7–15A

XTOBP60BC1

24–40

04

40–72A

XTOB040DC1

001

7–15A

XTOB001BC1

40–57

057

50–72A

XTOB057DC1

1P6

7–15A

XTOB1P6BC1

50–65

065

65–72A

XTOB065DC1

075

65–72A

XTOB075DC1

Frame B

Motor Full
Load Amperes
Frame D

1.6–2.4

2P4

7–15A

XTOB2P4BC1

65–75

1

2.4–4

004

7–15A

XTOB004BC1

Frame F

4–6

006

7–15A

XTOB006BC1

25–35

035

80–95A

XTOB055GC1 1

1

6–10

010

7–15A

XTOB010BC1

35–50

050

80–95A

XTOB050GC1 1

9–12

012

9–15A

XTOB012BC1

50–70

070

80–95A

XTOB070GC1 1

1

12–16

016

12–15A

XTOB016BC1

70–100

100

80–95A

XTOB100GC1 1

1

Frame C

Frame G

0.1–0.16

P16

18–32A

XTOBP16CC1

25–35

035

115–170A

XTOB055GC1 1

0.16–0.24

P24

18–32A

XTOBP24CC1

35–50

050

115–170A

XTOB050GC1 1

0.24–0.4

P40

18–32A

XTOBP40CC1

50–70

070

115–170A

XTOB070GC1 1

1

0.4–0.6

P60

18–32A

XTOBP60CC1

70–100

100

115–170A

XTOB100GC1 1

0.6–1

001

18–32A

XTOB001CC1

95–125

125

115–170A

XTOB125GC1 1

1

1–1.6

1P6

18–32A

XTOB1P6CC1

120–150

150

150–170A

XTOB150GC1 1

1.6–2.4

2P4

18–32A

XTOB2P4CC1

145–175

175

150–170A

XTOB175GC1 1

1

2.4–4

004

18–32A

XTOB004CC1

4–6

006

18–32A

XTOB006CC1

1

6–10

010

18–32A

XTOB010CC1

10–16

016

18–32A

XTOB016CC1

1

16–24

024

18–32A

XTOB024CC1

24–32

032

25–32A

XTOB032CC1

1

1
1
1
1

Electronic Overload Relay Suffix
XTOE Maximum Overload Rating
Standard Type Suffix

Ground Fault Type Suffix

Frame B

1

0.33–1.65A

5E1P6

5G1P6

1–5A

5E005

5G005

1

4–20A

5E020

5G020

1

0.33–1.65A

5E1P6

5G1P6

1–5A

5E005

5G005

1

4–20A

5E020

5G020

9–45A

5E045

5G045

1

Frame D
9–45A

5E045

5G045

1

20–100A

5E100

5G100

5E100

5G100

5E175

5G175

1
1
1

Frame C

Frame F, G
20–100A
Frame G
35–175A

Note
1 Catalog number refers to direct mount overload relay. Add an S to the end of the catalog number for separate mount.

1
V5-T1-54

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Star-Delta (Wye-Delta) Starters

1

Frame B—Maximum UL/CSA Ratings
Three-Phase hp Ratings
200V
230V

460V

575V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

3

2-1/2

10

<20

K1M main contactor

XTCE007B10_

K5M delta contactor

XTCE007B01_

K3M star contactor

XTCE007B01_

Mechanical interlock

XTCEXMLB

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…BC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLB

3

3

5

5

7-1/2

5

10

10

<20

15

<20

K1M main contactor

XTCE009B10_

K5M delta contactor

XTCE009B01_

K3M star contactor

XTCE009B01_

Mechanical interlock

XTCEXMLB

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…BC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLB

K1M main contactor

XTCE012B10_

K5M delta contactor

XTCE012B01_

K3M star contactor

XTCE012B01_

Mechanical interlock

XTCEXMLB

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…BC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLB

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V
380/400V
415V

500V

660/690V

1000V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

12

3

5.5

5.5

—

<20

K1M main contactor

XTCE007B10_

K5M delta contactor

XTCE007B01_

K3M star contactor

XTCE007B01_

Mechanical interlock

XTCEXMLB

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…BC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLB

K1M main contactor

XTCE009B10_

K5M delta contactor

XTCE009B01_

K3M star contactor

XTCE009B01_

Mechanical interlock

XTCEXMLB

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…BC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLB

K1M main contactor

XTCE012B10_

K5M delta contactor

XTCE012B01_

K3M star contactor

XTCE012B01_

Mechanical interlock

XTCEXMLB

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…BC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLB

16

22

4

5.5

7.5

11

7

8

14.5

1
1
1
1
1
1
1
1
1
1
1
1
1

Frame B—Maximum IEC Ratings

5.5

1

7.5

11

7.5

11

—

—

<20

<20

Note
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-55

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Frame C—Maximum UL/CSA Ratings

1
1

Three-Phase hp Ratings
200V
230V

460V

575V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

7-1/2

15

20

<20

K1M main contactor

XTCE018C10_

K5M delta contactor

XTCE018C01_

K3M star contactor

XTCE018C01_

Mechanical interlock

XTCEXMLC

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…CC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLC

K1M main contactor

XTCE025C10_

K5M delta contactor

XTCE025C01_

K3M star contactor

XTCE025C01_

Mechanical interlock

XTCEXMLC

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…CC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLC

K1M main contactor

XTCE032C10_

K5M delta contactor

XTCE032C01_

K3M star contactor

XTCE032C01_

Mechanical interlock

XTCEXMLC

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…CC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLC

7-1/2

1
1
1
1

10

15

30

40

<20

1
1
1
1

15

20

40

50

<20

1
1
1
1

Frame C—Maximum IEC Ratings

1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V
380/400V
415V

500V

660/690V

1000V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

30

7.5

18.5

18.5

—

<20

K1M main contactor

XTCE018C10_

K5M delta contactor

XTCE018C01_

K3M star contactor

XTCE018C01_

Mechanical interlock

XTCEXMLC

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…CC1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLC

K1M main contactor

XTCE025C10_

K5M delta contactor

XTCE025C01_

1

K3M star contactor

XTCE025C01_

Mechanical interlock

XTCEXMLC

1

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…CC1

1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLC

K1M main contactor

XTCE032C10_

K5M delta contactor

XTCE032C01_

1

K3M star contactor

XTCE032C01_

Mechanical interlock

XTCEXMLC

1

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…CC1

1

(3) auxiliary contacts

XTCEXFAC20

Star-delta link kit

XTCEXSDLC

1

15

19

1
1
1
1

45

1

55

1

11

15

22

30

30

39

30

37

22

30

—

—

<20

<20

Note
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62.

1
1
V5-T1-56

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Frame D—Maximum UL/CSA Ratings

1

Three-Phase hp Ratings
200V
230V

460V

575V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

20

50

60

<20

K1M main contactor
K5M delta contactor
K3M star contactor
Mechanical interlock
K1T timing relay
Overload relay
(2) auxiliary contacts (K1M, K3M)
(1) auxiliary contact (K5M)
Star-delta link kit
K1M main contactor
K5M delta contactor
K3M star contactor
Mechanical interlock
K1T timing relay
Overload relay
(2) auxiliary contacts (K1M, K3M)
(1) auxiliary contact (K5M)
Star-delta link kit
K1M main contactor
K5M delta contactor
K3M star contactor
Mechanical interlock
K1T timing relay
Overload relay
(2) auxiliary contacts (K1M, K3M)
(1) auxiliary contact (K5M)
Star-delta link kit

XTCE040D00_
XTCE040D00_
XTCE040D00_
XTCEXMLD
XTTR6A60S51B
XTOB…DC1
XTCEXFBG11
XTCEXFBG31
XTCEXSDLD
XTCE050D00_
XTCE050D00_
XTCE040D00_
XTCEXMLD
XTTR6A60S51B
XTOB…DC1
XTCEXFBG11
XTCEXFBG31
XTCEXSDLD
XTCE065D00_
XTCE065D00_
XTCE040D00_
XTCEXMLD
XTTR6A60S51B
XTOB…DC1
XTCEXFBG11
XTCEXFBG31
XTCEXSDLD

25

25

30

40

60

50

75

100

<20

125

<20

Frame D—Maximum IEC Ratings
Three-Phase Motors 50–60 Hz
220/230V 380/400V 415V

500V

660/690V

1000V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

70

18.5

45

37

—

<20

K1M main contactor
K5M delta contactor
K3M star contactor
Mechanical interlock
K1T timing relay
Overload relay
(2) auxiliary contacts (K1M, K3M)
(1) auxiliary contact (K5M)
Star-delta link kit
K1M main contactor
K5M delta contactor
K3M star contactor
Mechanical interlock
K1T timing relay
Overload relay
(2) auxiliary contacts (K1M, K3M)
(1) auxiliary contact (K5M)
Star-delta link kit
K1M main contactor
K5M delta contactor
K3M star contactor
Mechanical interlock
K1T timing relay
Overload relay
(2) auxiliary contacts (K1M, K3M)
(1) auxiliary contact (K5M)
Star-delta link kit

XTCE040D00_
XTCE040D00_
XTCE040D00_
XTCEXMLD
XTTR6A60S51B
XTOB…DC1
XTCEXFBG11
XTCEXFBG31
XTCEXSDLD
XTCE050D00_
XTCE050D00_
XTCE040D00_
XTCEXMLD
XTTR6A60S51B
XTOB…DC1
XTCEXFBG11
XTCEXFBG31
XTCEXSDLD
XTCE065D00_
XTCE065D00_
XTCE040D00_
XTCEXMLD
XTTR6A60S51B
XTOB…DC1
XTCEXFBG11
XTCEXFBG31
XTCEXSDLD

90

115

22

30

45

55

37

45

55

55

75

45

55

—

—

<20

<20

1
1
1
1
1
1
1
1
1
1
1
1
1

AC-3
I e (A)

37

1

Note
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-57

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Frame F—Maximum UL/CSA Ratings

1

Three-Phase hp Ratings

1

200V

230V

460V

575V

Max. Changeover
Time (sec)

40

60

125

150

<20

1

Component
Description

Catalog Number 1

K1M main contactor

XTCE080F00_

K5M delta contactor

XTCE080F00_

K3M star contactor

1

Mechanical interlock

XTCE080F00_
2

XTCEXMLG

1

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…FC1

1

(2) auxiliary contacts (K1M, K3M)

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

1

Star-delta link kit

XTCEXSDLF

K1M main contactor

XTCE095F00_

K5M delta contactor

XTCE095F00_

1

K3M star contactor

XTCE080F00_

Mechanical interlock 2

XTCEXMLG

1

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…FC1

1

(2) auxiliary contacts (K1M, K3M)

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

Star-delta link kit

XTCEXSDLF

Component
Description

Catalog Number 1

K1M main contactor

XTCE080F00_

K5M delta contactor

XTCE080F00_

40

1

60

125

150

<20

1
1
Frame F—Maximum IEC Ratings

1
1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

500V

660/690V

1000V

Max. Changeover
Time (sec)

140

37

75

75

90

90

—

<20

1

K3M star contactor

XTCE080F00_

Mechanical interlock 2

XTCEXMLG

1

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…FC1

1

(2) auxiliary contacts (K1M, K3M)

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

Star-delta link kit

XTCEXSDLF

K1M main contactor

XTCE095F00_

K5M delta contactor

XTCE095F00_

1

K3M star contactor

XTCE080F00_

Mechanical interlock 2

XTCEXMLG

1

K1T timing relay

XTTR6A60S51B

1

Overload relay

XTOB…FC1

(2) auxiliary contacts (K1M, K3M)

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

Star-delta link kit

XTCEXSDLF

1

1
165

1

45

90

110

110

132

—

<20

1
1

Notes
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62.
2 If mechanical interlock of star contactor is required, it must be the same frame size of the delta contactor or use the same
mechanical interlock, see Page V5-T1-73 for mechanical interlocks. (Example: XTCE…L22_ and XTCE…M22_ both use
mechanical interlock XTCEXMLM.)

1
1
1
1
V5-T1-58

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Frame G—Maximum UL/CSA Ratings
Three-Phase hp Ratings
200V

230V

460V

575V

Max. Changeover
Time (sec)

50

60

125

150

<20

75

100

200

250

<20

1

Component
Description

Catalog Number

K1M main contactor

XTCE115G00_

K5M delta contactor

XTCE115G00_

K3M star contactor

XTCE080F00_

Mechanical interlock

XTCEXMLG

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…GC1

(2) auxiliary contacts

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

Star-delta link kit

XTCEXSDLG

K1M main contactor

XTCE150G00_

K5M delta contactor

XTCE150G00_

K3M star contactor

XTCE080F00_

Mechanical interlock

XTCEXMLG

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…GC1

(2) auxiliary contacts

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

Star-delta link kit

XTCEXSDLG

1

1
1
1
1
1
1
1
1
1
1
1
1

Frame G—Maximum IEC Ratings
AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

500V

660/690V

200

55

110

132

132

160

260

75

132

148

160

160

1

1000V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

—

<20

K1M main contactor

XTCE115G00_

K5M delta contactor

XTCE115G00_

K3M star contactor

XTCE080F00_

Mechanical interlock

XTCEXMLG

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…GC1

(2) auxiliary contacts

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

Star-delta link kit

XTCEXSDLG

K1M main contactor

XTCE150G00_

K5M delta contactor

XTCE150G00_

K3M star contactor

XTCE080F00_

Mechanical interlock

XTCEXMLG

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…GC1

(2) auxiliary contacts

XTCEXFBG11

(1) auxiliary contact (K5M)

XTCEXFBG31

Star-delta link kit

XTCEXSDLG

—

<20

1
1
1
1
1
1
1
1
1
1
1
1

Note
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62.

1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-59

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Frame L—Maximum UL/CSA Ratings

1
1

Three-Phase hp Ratings
200V
230V

460V

575V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

125

300

400

<30

K1M main contactor

XTCS250L22_

K5M delta contactor

XTCS250L22_

K3M star contactor

XTCS250L22_

Mechanical interlock

XTCEXMLM

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…LC1

150

1
1
1
Frame L—Maximum IEC Ratings

1
1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V 380/400V 415V

500V

660/690V

1000V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

430

132

315

400

200

<30

K1M main contactor

XTCS250L22_

K5M delta contactor

XTCS250L22_

K3M star contactor

XTCS250L22_

Mechanical interlock

XTCEXMLM

K1T timing relay

XTTR6A60S51B

Overload relay

XTOB…LC1

250

300

1
1
1
Frame M—Maximum UL/CSA Ratings

1

Three-Phase hp Ratings
200V
230V

460V

575V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

200

500

600

<20

K1M main contactor

XTCS400M22_

1

K5M delta contactor

XTCS400M22_

K3M star contactor

XTCS250L22_

1

Mechanical interlock

XTCEXMLM

K1T timing relay

XTTR6A60S51B

1

Overload relay

XTOT…C3S

K1M main contactor

XTCS500M22_

K5M delta contactor

XTCS500M22_

K3M star contactor

XTCS300M22_

Mechanical interlock

XTCEXMLM

K1T timing relay

XTTR6A60S51B

Overload relay

XTOT…C3S

1

250

290

350

700

860

<30

1
1
1
1

Frame M—Maximum IEC Ratings

1

AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V 380/400V 415V

500V

660/690V

1000V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

1

685

200

450

560

220

<20

K1M main contactor

XTCS400M22_

K5M delta contactor

XTCS400M22_

1

K3M star contactor

XTCS250L22_

Mechanical interlock

XTCSXMLM

1

K1T timing relay

XTTR6A60S51B

Overload relay

XTOT…C3S

K1M main contactor

XTCS500M22_

1

K5M delta contactor

XTCS500M22_

K3M star contactor

XTCS300M22_

1

Mechanical interlock

XTCEXMLM

K1T timing relay

XTTR6A60S51B

1

Overload relay

XTOT…C3S

1

860

250

355

450

390

500

560

600

220

<30

Notes
1 Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62.
2 If mechanical interlock of star contactor is required, it must be the same frame size of the delta contactor or use the same
mechanical interlock, see Page V5-T1-73 for mechanical interlocks. (Example: XTCE…L22_ and XTCE…M22_ both use
mechanical interlock XTCEXMLM.)

1
1
1
V5-T1-60

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Frame N—Maximum UL/CSA Ratings are not applicable.

1

Frame N—Maximum IEC Ratings
AC-3
I e (A)

Three-Phase Motors 50–60 Hz
220/230V

380/400V

415V

500V

660/690V

1000

300

560

610

710

900

1120

350

630

680

750

950

1

1000V

Max. Changeover
Time (sec)

Component
Description

Catalog Number 1

355

<30

K1M main contactor

XTCE580N22_

K5M delta contactor

XTCE580N22_

K3M star contactor

XTCE580N22_

Mechanical interlock 2

XTCEXMLN

K1T timing relay

XTTR6A60S51B

Overload relay

XTOT…C3S

K1M main contactor

XTCE650N22_

K5M delta contactor

XTCE650N22_

355

<30

K3M star contactor
Mechanical interlock

1290

1400

1700

400

450

560

710

800

1000

760

850

1050

900

950

1200

1200

1300

1700

1400

1400

1700

<30

<30

<20

XTCE580N22_
2

XTCEXMLN

K1T timing relay

XTTR6A60S51B

Overload relay

XTOT…C3S

K1M main contactor

XTCE750N22_

K5M delta contactor

XTCE750N22_

K3M star contactor

XTCE580N22_

Mechanical interlock

XTCEXMLN

K1T timing relay

XTTR6A60S51B

Overload relay

XTOT…C3S

K1M main contactor

XTCE820N22_

K5M delta contactor

XTCE820N22_

K3M star contactor

XTCE580N22_

Mechanical interlock

XTCEXMLN

K1T timing relay

XTTR6A60S51

Overload relay

XTOT…C3S

K1M main contactor

XTCEC10N22_

K5M delta contactor

XTCEC10N22_

K3M star contactor

XTCE650N22_

Mechanical interlock

XTCEXMLN

K1T timing relay

XTTR6A60S51B

Overload relay

XTOT…C3S

Notes
Main circuit: Depending on the coordination type required (i.e., Type 1 or Type 2) it must be established whether the fuse protection and the input wiring for the main and
delta contactors are to be common or separate.
Control circuit: If the combinations are used in the scope of the IEC/EN 60 204-1, VDE 0113 part 1, point 9.1.1 regarding the supply of control circuits is to be observed.
1
2

Underscore (_) indicates magnet coil suffix required. See Page V5-T1-62.
If mechanical interlock of star contactor is required, it must be the same frame size of the delta contactor or use the same mechanical interlock,
see Page V5-T1-73 for mechanical interlocks. (Example: XTCE…L22_ and XTCE…M22_ both use mechanical interlock XTCEXMLM.)

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-61

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Spare Auxiliary Contacts

1

AC-3

1

12–55

1

90–260

1

K1M

K3M

K5M

63

63

63

64

64

64

21 33

—

—

22 34
315–1700

1

21 31

31 43

31 43

22 32

32 44

32 44

1
1
1
1
1
1

Magnet Coil Suffix
Coil Voltage

Suffix Code

Frames A–B

Coil Voltage

Suffix Code

Frames C–F

Coil Voltage

Suffix Code

Frame G

Coil Voltage

Suffix Code

Frames L–N

110V 50 Hz, 120V 60 Hz

A

110V 50 Hz, 120V 60 Hz

A

100–120V 50/60 Hz

A

110–250 Vdc 40–60 Hz

220V 50 Hz, 240V 60 Hz

B

220V 50 Hz, 240V 60 Hz

B

190–240V 50/60 Hz

B

250–500V 40–60 Hz

A
C

230V 50 Hz

F

230V 50 Hz

F

24V 50/60 Hz

T

48–110 Vdc 40–60 Hz

Y

24V 50/60 Hz

T

24V 50/60 Hz

T

24–27 Vdc

TD

24–48 Vdc

TD 1

Frames L–M, S-Series

24 Vdc

TD

24–27 Vdc

TD

480–500V 50/60 Hz

C

415V 50 Hz, 480V 60 Hz

C

415V 50 Hz, 480V 60 Hz

C

380–440V 50/60 Hz

L

110–120V 50/60 Hz

A

550V 50 Hz, 600V 60 Hz

D

550V 50 Hz, 600V 60 Hz

D

42–48V 50/60 Hz

W

220–240V 50/60 Hz

B

1

208V 60 Hz

E

208V 60 Hz

E

110–130 Vdc

AD

Frames P–R

190V 50 Hz, 220V 60 Hz

G

190V 50 Hz, 220V 60 Hz

G

200–240 Vdc

BD

230–250 Vdc 50–60 Hz

1

240V 50 Hz, 277V 60 Hz

H

240V 50 Hz, 277V 60 Hz

H

48–60 Vdc

WD

1

380V 50 Hz, 440V 60 Hz

L

380V 50 Hz, 440V 60 Hz

L

Frame H

400V 50 Hz

N

400V 50 Hz

N

100–120V 50/60 Hz

A

1

380V 60 Hz

P

380V 60 Hz

P

190–240V 50/60 Hz

B

12V 50/60 Hz

R

12V 50/60 Hz

R

480–500V 50/60 Hz

C

1

42V 50 Hz, 48V 60 Hz

W

42V 50 Hz, 48V 60 Hz

W

380–440V 50/60 Hz

L

48V 50 Hz

Y

48V 50 Hz

Y

24V 50/60Hz

T

120 Vdc

AD

110–130 Vdc

AD

42–48V 50/60Hz

W

220 Vdc

BD

200–240 Vdc

BD

110–130 Vdc

AD

12 Vdc

RD

48–60 Vdc

WD

200–240 Vdc

BD

48 Vdc

WD

24–27 Vdc

TD

48–60 Vdc

WD

1

1
1
1
1
1

Overload Relay Settings (A)
Setting

Starting

A: IN x 0.58
Motor protection in the star (wye) and delta configurations

<15 sec

1

B: IN x 1
Only partial motor protection in star position

15–40 sec

1

C: IN x 0.58
Motor not protected in star (wye) position

>40 sec

1

Timing relay set to approximately 10 sec

1

1

Note
1 Frames L–M only.

1
1
1
V5-T1-62

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

B

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

XTCC0_

1.1

XTCC Contactors for Three-Phase Capacitors

1

Three-Phase Capacitors, 50–60 Hz
Open kVAR Ratings 1
230V

400V

525V

690V

11

20

25

33.3

15

25

33.3

40

1

Catalog Number 2

Contact Sequence

XTCC020C11_

A1

1 3 5 13 21

A2

2 4 6 14 22

1

XTCC025C11_

1
1

20

33.3

40

55

25

50

65

85

XTCC033D10_

A1

1 3 5 13

A2

2 4 6 14

1

XTCC050D10_

1
1
1

Magnet Coil Suffix
Coil Voltage

Suffix Code

110V 50 Hz, 120V 60 Hz

A

220V 50 Hz, 240V 60 Hz

B

230V 50 Hz, 240V 60 Hz

F

400V 50 Hz, 440V 60 Hz

N

24V 50/60 Hz

T

1
1
1
1

Notes
Weld-resistant for capacitors with inrush current peaks up to 180 x IN.
1
2

1

With series resistors, without quick-discharge resistor.
Underscore (_) indicates magnet coil suffix required.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-63

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Engineering Notes for XTCC and XTCE Contactors for Power Factor Correction
Individual Compensation, Open Version

Group Compensation, with Reactor, Open Version

Catalog
Number

Switching Duty in kVAR
400V, 420V, 440V

525V

690V

Catalog
Number

Switching Duty in kVAR

230V

230V

400V, 420V, 440V

525V

XTCE007B

1.5

3

3.5

5

XTCE007B

4

7

7.5

12

1

XTCE009B

2

4

4.5

6

XTCE009B

5

8

10

14

XTCE012B

2.5

4.5

5.5

7

XTCE012B

5.5

1

12

16

1

XTCE015B

2.5

4.5

5.5

7

XTCE015B

5.5

10

12

16

XTCE018C

6.5

12

14.5

19

XTCE018C

7.5

16

20

28

XTCE025C

7

13.5

16

21

XTCE025C

9

18

23

30

1

XTCE032C

7.5

14.5

17

22.5

XTCE032C

10

20

24

32

XTCE040D

11

20.5

24.5

32

XTCE040D

13

25

30

40

1

XTCE050D

11.5

22

26

34.5

XTCE050D

16

30

36

48

XTCE065D

12.5

23.5

28

37

XTCE065D

19

36

43

57

XTCE080F

16

30.5

36.5

48

XTCE080F

30

58

68

90

1

XTCE095F

18

34

41

54

XTCE095

34

6

7

10

XTCE115G

24

46

54.5

72

XTCE115G

44

8

100

125

1

XTCE150G

28

53

63.5

83.5

XTCE150

5

97

115

152

XTCE580N

175

300

400

300

XTCE250L

110

190

260

340

XTCE400M

160

280

370

480

XTCE500M

220

390

500

680

1

1

1

1
1

690V

1

Group Compensation, without Reactor, Open Version

1

Catalog
Number

Switching Duty in kVAR
230V

400V, 420V, 440V

525V

1

XTCC020C

11

20

25

33.3

XTCC025C

15

25

33.3

40

1

XTCC033D

20

33.3

40

55

1

XTCC050D

25

50

65

85

XTCE580N

145

250

333

250

1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-64

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

690V

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Accessories

1

Auxiliary Contacts
Front-mounted snap-on
auxiliary contacts for XT
contactors are available
with screw or spring cage
terminals in a variety of
contact configurations.

1
1
1
1

Auxiliary Contacts Possible Combinations
Frame
Size

Catalog
Number

A

XTMC6A_ –
XTMC9A_

B

XTCE007B_ –
XTCE015B_

Contactor

Built-In
Auxiliary

Front (Top) Mount
Two-Pole

Four-Pole

Single-Pole

Two-Pole

Total Auxiliary
Contacts Available

1NO or 1NC

1

—

—

—

3

—

1

1NO or 1NC

Side-Mount

—

—

5

—

—

—

1

—

—

—

3

—

1

—

—

5

—

—

1

—

2

—

—

1
1
1
1
1
1
1
1

C

XTCE018C_ –
XTCE032C_

1NO or 1NC

1

—

—

—

3

—

1

—

—

5

—

—

—

1

3

—

1
1

—

1
D

XTCE040D00_ –
XTCE065D00_

—

1

—

—

2

6

—

1

—

1

6

—

1
1

—

1
F–G

XTCE080F00_ –
XTCE150G00_

—

1

—

—

2

6

—

1

—

2

8

—

—

—

4

8

—

1
1
1

—

1
L–R

XTCE185H22_ –
XTCEC20R22_

2NO–2NC

—

—

—

—

2

1

8
—

1
1
1

Notes
Forced operation contact to IEC/EN 60947-5-1 Appendix L (positively driven), inside the auxiliary contact unit
(not early close and late opening).
Auxiliary normally closed contact can be used as mirror contact to IEC/EN 60947-4-1 Appendix F (not late opening).
No auxiliary contacts can be fitted between two contactors.

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-65

1

IEC Contactors and Starters
XT IEC Power Control

Auxiliary Contact Combinations

1

XTMC6A_–XTMC9A_

1

XTMCXF...A_
Two-Pole or Four-Pole

1
1

XTCE007B_– XTCE032C_

1
1

XTCEXF...C_
Two-Pole or Four-Pole

or

1

1

1

+

1
1

XTCEXF...G_
Four-Pole

+

or

+

+

XTCE080F_–XTCE150G_

+

XTCE185H_–XTCEC20R_

+

+

Frames L–R

V5-T1-66

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

+

+

XTCEXSCN11

XTCEXSCN11

+

Frames F–G

1
1

XTCEXF...G_
Two-Pole or Four-Pole

+

XTCEXSBR11 (Built-In)

1

+

XTCE080F_–XTCE150G_
XTCEXSBN11

1

or

Frame D

1
1

+

XTCEXSBR11 (Built-In)

1

XTCEXF...G_
Two-Pole

+

XTCE040D_– XTCE065D_
XTCEXSBN11

1

XTCEXSBN11

1

XTCE040D_– XTCE065D_

XTCEXSBN11

1
1

XTCE018C_–XTCE032C_

Frame C

XTCEXSBN11

1

+

XTCEXSBN11

1

Frame B
Not for use with mechanical interlock.

XTCEXSBN11

1

XTCEXF...C_
Two-Pole or Four-Pole

or

XTCE007B_–XTCE015B_

XTCEXSBN11

1

+

XTCEXSCC11

1

XTCE007B_–XTCE015B_

XTCEXSCR11

1

Frame A

XTCEXSAB_

1

XTCEXSCR11

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Auxiliary Contacts
XTCEXF_

1
Frames B–C, Front (Top) Mount—Two-Pole
Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

16

2NO

1

Circuit
Symbol

53 63

Pkg.
Qty. 1

Screw Terminal
Catalog Number

1

5

XTCEXFAC20

1

5

XTCEXFAC11 4

5

XTCEXFAC02

5

XTCEXFALC11 2

5

XTCEXFDC11 3

5

XTCEXFCC02 3

54 64
16

1NO-1NC

53 61

1
1

54 62
16

2NC

51 61

1

52 62
1NOE-1NCL

16

57 65

1
1

58 66
16

1NO-1NC

16

2NC

21 31

1
1
1

22 32

1
XTCEXF_

Frames B–C, Front (Top) Mount—Four-Pole
Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

16

4NO

Circuit
Symbol

53 6373 83

1
Pkg.
Qty. 1

Screw Terminal
Catalog Number

1

5

XTCEXFAC40 4

1

5

XTCEXFAC31 4

5

XTCEXFAC22 4

5

XTCEXFAC13

5

XTCEXFAC04

5

XTCEXFCLC22 2

5

XTCEXFCC22 3

54 6474 84
16

3NO-1NC

53 61 73 83

16

2NO-2NC

53 61 71 83

1
1

54 62 74 84

1

54 62 72 84
16

1NO-3NC

536171 81

1
1

54 62 72 82
16

4NC

51 61 71 81

1

52 62 72 82
16

1NOE-1NCL

5765 71 83

1
1

58 66 72 84
16

2NO-2NC

21 31 43 53

1

22 32 44 54

1
1

Notes
1 Orders must be placed in multiples of package quantity listed.
2 1 early-make contact (1NO ), 1 late-break contact (1NC ).
E
L
3 To avoid duplicate terminal numbers in contact sequence, these auxiliary contacts should only be used with contactors
having a built-in 1NO contact (XTCE…B10_, XTCE…C10_).
4 Catalog number is shown with screw type terminal. For spring cage, add a “C” before the last 2 digits. For example,
to order a spring cage version of the XTCEXFAC22, change the catalog number to XTCEXFACC22.

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-67

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

XTCEXFATC_

1
1

IEC Contactors and Starters
XT IEC Power Control

Frames B–C, Front (Top) Mount—Tall Version Two-Pole 1
Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

16

2NO

Circuit
Symbol

53 63

Pkg.
Qty. 2

Screw Terminal
Catalog Number

5

XTCEXFATC20

5

XTCEXFATC11

5

XTCEXFATC02

54 64

1

16

1NO-1NC

53 61

1

54 62
16

1

2NC

51 61
52 62

1
1

XTCEXFATC22

Frames B–C, Front (Top) Mount—Tall Version Four-Pole 1

1

Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

1

16

2NO-2NC

53 61 71 83

Pkg.
Qty. 2

Screw Terminal
Catalog Number

5

XTCEXFATC22

Pkg.
Qty. 2

Screw Terminal
Catalog Number

1

XTCEXSAB10 3

1

XTCEXSAB01 3

Pkg.
Qty. 2

Screw Terminal
Catalog Number

1

XTCEXSCC11 3

54 62 72 84

1
1

Circuit
Symbol

XTCEXSAB_

1
1

Frame B, Side-Mount—Single-Pole
Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

16

1NO

Circuit
Symbol
53

1
1

54

16

1NC

51

1
52

1
1
1

XTCEXSCC11

1

Frame C, Side-Mount—Two-Pole
Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

10

1NO-1NC

Circuit
Symbol

53 61

1

54 62

1

Notes
Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules
(not NO [early make] and NC [late break] contacts) and for the built-in auxiliary contacts of the XTCE007B_–XTCE032C_.

1

Auxiliary break contact can be used as mirror contact to IEC/EN 60947-4-1 Annex F (not NC [late break] contact).

1

No auxiliary contacts can be fitted between two contactors.
1

1

2
3

1

Front (top) mount tall version is for use with Frame B electrical wire bridges and link kits (see Page V5-T1-74) and
toolless plug combination connection kits: XTCEXRLB, XTCEXSDLB, XTPAXTPCB, XTPAXTPCRB, XTPAX.
Orders must be placed in multiples of package quantity listed.
Can be mounted to the left side of contactor only. Cannot be used in combination with front (top) mount auxiliary
contacts or mechanical interlocks.

1
1
1
V5-T1-68

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

XTCEXF_

1.1

Frames D–G—Two-Pole

1

Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

16

2NO

Circuit
Symbol

13 23

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTCEXFBG20

5

XTCEXFAG11

5

XTCEXFBG11

1
1

14 24
16

1NO-1NC

53 61

1

54 62
16

1NO-1NC

13 21

1
1

14 22
16

2NC

11 21

5

XTCEXFBG02

1

12 22

XTCEXF_

1
1

Frames D–G—Four-Pole
Conventional Thermal Current,
Open at 60°C
Ith = Ie, AC-1 in Amps

Contact
Configuration

16

4NO-0NC

Circuit
Symbol

13 23 33 43

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTCEXFBG40

5

XTCEXFBG31

1
1
1

14 24 34 44
16

3NO-1NC

13 21 33 43

1

14 22 34 44
16

2NO-2NC

13 21 31 43

5

XTCEXFBG22

5

XTCEXFAG_22 2

1

14 22 32 44
16

2NO-2NC

53 61 71 83

1
1

54 62 72 84
16

1NO-3NC

13 21 31 41

5

XTCEXFBG13

5

XTCEXFBG04

5

XTCEXFBLG22 3

1

14 2232 42
16

0NO-4NC

16

1NOE-1NCL

11 2131 41

1
1

12 2232 42
13 21 35 47

1

14 22 36 48

1

Notes
Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules
(not NO (early make) and NC (late break) contacts) and for the built-in auxiliary contacts of the XTCE007B_–XTCE032C_.

1

Auxiliary break contact can be used as mirror contact to IEC/EN 60947-4-1 Annex F (not NC (late break) contact).

1

No auxiliary contacts can be fitted between two contactors.
1
2

3

Orders must be placed in multiples of package quantity listed.
A “_” denotes catalog numbers are incomplete. To complete the catalog number for ordering a spring cage terminal,
insert a C in the “_” position or remove “_” for screw type terminal.
One early-make contact (1NOE), one late-break contact (1NCL).

1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-69

10

1NO–1NC

13

53
54

1
Conventional Free Air
Thermal Current,
Ith = Ie, AC-1 in Amps

Contact
Configuration

Circuit
Symbol

10

1NO–1NC

13

22

17

48

83

1

61
62

71

54

84

53

72

1NO–1NC

47

10

1

26

35

18

1

25

36

1NOE–1NCL

14

43

10

21

31

1
1

Pkg.
Qty. 1

Screw Terminal
Catalog Number

1

XTCEXSBN11

1

XTCEXSBLN11 2

1

XTCEXSCN11 3

Frames H–R, 40–2000A Side Mount (Screw Mount)—Two-Pole

44

1

62

32

XTCEXS_

1

61

83

1NO–1NC

26

71

10

25

84

18

1
1

17

72

1

22

47

1NOE–1NCL

14

35

10

21

48

1

Circuit
Symbol

36

1

Contact
Configuration

43

1

Frames D–G, 40–170A Side Mount (Snap-On)—Two-Pole
Conventional Free Air
Thermal Current,
Ith = Ie, AC-1 in Amps

31

XTCEXS_

XT IEC Power Control

44

1

IEC Contactors and Starters

32

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

Pkg.
Qty. 1

Screw Terminal
Catalog Number

1

XTCEXSBR11 4

1

XTCEXSBLR11

1

XTCEXSCR11

Notes
1 Orders must be placed in multiples of package quantity listed.
2 1 early-make contact (1NO ), 1 late-break contact (1NC ).
E
L
3 To avoid duplicate terminal numbers in contact sequence, the XTCEXSCN11 should be used with Frame D
when a top mount auxiliary is also installed.
4 For replacement only. XTCEXSBR11 and XTCEXSBLR11 cannot be added onto side mount auxiliaries that come with
the Frames L–R contactors as standard. To add auxiliaries onto the included side auxiliaries on Frames L–R
contactors, use XTCEXSCR11.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-70

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Suppressors
The switching of contactor
coils can generate voltage
transients that may cause
arching on switch contacts
and/or damage electronics on
the control line. Either an RC
or varistor suppressor is
recommended in these types
of applications. All XT DC
contactor coils have built-in
suppression.

Varistor suppressors clamp
the voltage transient above
the maximum coil voltage and
are recommended when the
level of the transient is
known to not exceed the coil
voltage. RC suppressors slow
and reduce the level of the
voltage transient but do not
clamp them at a specific
level. The slowing of the
transient can reduce
electrical interference.
These are recommended in
applications where operating
rates are high.

1

RC Suppressor 12

XTCEXRS_

Voltage
24–48

XTCEXRSBW
XTCEXRSBA

110–240

10

XTCEXRSBB

240–500

10

XTCEXRSBC

10

XTCEXRSCW

10

XTCEXRSCA

130–240

10

XTCEXRSCB

240–500

10

XTCEXRSCC

10

XTCEXRSFW

110–130

A2

Catalog Number

10

24–48

A1

24–48
110–130

XTCE007B–
XTCE015B,
XTCF020B

Pkg.
Qty. 3

10

48–130

Contact Sequence

For Use
with…

XTCE018C–
XTCE032C

XTCE040D–
XTCE095F

10

XTCEXRSFA

130–240

10

XTCEXRSFB

240–500

10

XTCEXRSFC

1
1
1
1
1
1
1
1
1

XTCEXVS_

Varistor Suppressor 12
Voltage
24–48
48–130

Contact Sequence

A1

A2

Pkg.
Qty. 3

Catalog Number

XTCE007B–
XTCE015B,
XTCF020B

10

XTCEXVSBW

10

XTCEXVSBA

10

XTCEXVSBB

240–500

10

XTCEXVSBC

48–130

XTCE018C–
XTCE032C

10

XTCEXVSCW

10

XTCEXVSCA

130–240

10

XTCEXVSCB

240–500

10

XTCEXVSCC

24–48

10

XTCEXVSFW

10

XTCEXVSFA

130–240

10

XTCEXVSFB

240–500

10

XTCEXVSFC

48–130

XTCEXDSB

XTCEXVSL_

For Use
with…

130–240

24–48

XTCE040D–
XTCE095F

Varistor Suppressor with
Integrated LED 12

Free-Wheel Diode Suppressor 4
Voltage
DC

For Use
with…

Pkg.
Qty. 3

Catalog Number

12–250

XTCE007B–
XTCE015B,
XTCF020B

10

XTCEXDSB

For Use
with…

Pkg.
Qty. 3

Catalog Number

24–48

XTCE007B–
XTCE015B

10

XTCEXVSLBW

10

XTCEXVSLBB

XTCE018C–
XTCE032C

10

XTCEXVSLCW

10

XTCEXVSLCB

XTCE040D–
XTCE095F

10

XTCEXVSLFW

10

XTCEXVSLFB

130–240
24–48
Contact Sequence
A1
A2

1

Voltage
AC

130–240
24–48
130–240

Notes
1 Note dropout delay.
2 For AC operated contactors, 50–60 Hz. DC operated contactors and XTCE115G_
to XTCE170G_ have a built-in suppressor circuit.
3 Orders must be placed in multiples of package quantity listed.
4 In addition to the built-in suppressor circuit for DC actuated contactors. Prevents
negative breaking voltage when contactors are used in combination with a safety PLC.

1
1
1
1
1
1
1
1
1
1
1
1

Contact Sequence

1

A1

1
1

A2

1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-71

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

XT IEC Power Control

Electronic Timer Modules
Frames B–C Contactors (7–32A) 1

1
1

IEC Contactors and Starters

Voltage
XTCEXTE_

A1

100–130 Vac

1

Timing
Range

For Use
with…

Pkg.
Qty. 2

Catalog Number

0.05s–1s
0.5s–10s
5s–100s

XTCE…B_
XTCE…C_

1

XTCEXTEEC11T

1

XTCEXTEEC11A

1

XTCEXTEEC11B

XTCE…B_
XTCE…C_

1

XTCEXTED1C11T

1

XTCEXTED1C11A

1

XTCEXTED1C11B

XTCE…B_
XTCE…C_

1

XTCEXTED10C11T

1

XTCEXTED10C11A

1

XTCEXTED10C11B

1

XTCEXTED100C11T

1

XTCEXTED100C11A

1

XTCEXTED100C11B

1

XTCEXTEYC20T

1

XTCEXTEYC20A

1

XTCEXTEYC20B

1

XTCEXTESHRD

On-Delay
24 Vac/Vdc

1

A2

200–240 Vac

57 65
58 66

Off-Delay

1

24 Vac/Vdc

1

100–130 Vac

1

24 Vac/Vdc

A1
A2

200–230 Vac

A1

100–130 Vac

1

A2

200–240 Vac
24 Vac/Vdc

1

A1

100–130 Vac

1

200–240 Vac

1

24 Vac/Vdc

1

200–240 Vac

1

Contact
Sequence

A2

57 65

0.05s–1s

58 66
57 65

0.5s–10s

58 66
57 65

5s–100s

XTCE…B_
XTCE…C_

58 66

Star-Delta

A1

100–130 Vac

XTCEXTESHRD

1

1s–30s

XTCE…B_
XTCE…C_

58 68

Sealable Shroud
—

1

A2

57 67

Transparent sealable shroud used to
protect electronic timer modules from
unwanted access

XTCEXTEE,
XTCEXTED,
XTCEXTEY

Notes
1 Front (top) mounted timer modules for use with XTCE…B and XTCE…C contactors.
Cannot be combined with top-mount auxiliary contacts, XTCEXF…C_.
2 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-72

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Additional Accessories

1

Mechanical Interlock 1

XTCEXMLB

XTCEXML_

XTCEXMLM

XTCEXMLN

Star-Delta (Wye-Delta) Link Kits

For Use
with…

Pkg.
Qty. 2

Catalog Number

XTCE007B–XTCE015B,
XTCF020B

5

XTCEXMLB

XTCE018C–XTCE032C,
XTCF032C–XTCF045C

1

XTCEXMLC

XTCE040D–XTCE072D,
XTCF063D–XTCF080D

1

XTCEXMLD

XTCE080F–XTCE170G,
XTCF125G–XTCF200G

1

XTCEXMLG 3

XTCE185H–XTCE570M

1

XTCEXMLM

XTCE580N–XTCEC10N

XTCEXSDLB

1

For Use
with…

Pkg.
Qty. 2

Catalog Number

XTCE007B–XTCE015B

1

XTCEXSDLB 3

1
1
1
XTCEXSDL_

XTCEXMLN 3

1

XTCE018C–XTCE032C

1

XTCEXSDLC

XTCE040D–XTCE065D

1

XTCEXSDLD

XTCE080F–XTCE095F

1

XTCEXSDLF

XTCE115G–XTCE150G

1

XTCEXSDLG

Main current wiring for star-delta (wye-delta) combinations.
includes paralleling bridge, reversing bridge and star-delta
bridge. Does not include mechanical interlock, see table on
this page.

Reversing Link Kits

XTCEXRLB

XTCE007B–XTCE015B

Pkg.
Qty. 2
1

For Use
with…

Pkg.
Qty. 2

Catalog Number

XTCEXPBB

XTCE007B–XTCE015B

20

XTCEXPBB

XTCEXPBC

XTCE018C–XTCE032C

20

XTCEXPBC

XTCEXRLB

Component part of reversing link kit (XTCEXRL_). Parallels the
phases on the line-side of two contactors.
XTCEXRL_

XTCE018C–XTCE032C

1

XTCEXRLC

XTCE040D–XTCE065D

1

XTCEXRLD

Reversing Bridge

XTCE080F–XTCE150G

1

XTCEXRLG

For Use
with…

Pkg.
Qty. 2

Catalog Number

XTCEXRBB

XTCE007B–XTCE015B

20

XTCEXRBB

XTCEXRB_

XTCE018C–XTCE032C

20

XTCEXRBC

XTCE040D–XTCE065D

10

XTCEXRBD

Main current wiring for reversing combinations. Includes
paralleling bridge and reversing bridge. Does not include
mechanical interlock, see table on this page.

1
1
1
1
1
1
1

Catalog Number
4

1

1

Paralleling Bridge

For Use
with…

1

1
1
1
1

Component part of reversing link kit (XTCEXRL_). Reverses the
phases on the load-side of two contactors.

1
1
1
1
1
1
1

Notes
1 For two contactors with AC or DC operated magnet system which are horizontally or vertically mounted. For Frames B–G, mechanical lifespan is 2.5 x 106 operations
and the distance between contactors is 0 mm. For Frames L–N, mechanical lifespan is 5 x 106 operations and no auxiliary contact can be mounted between the
mechanical interlock and the contactor—the distance between contactors is 15 mm.
2 Orders must be placed in multiples of package quantity listed.
3 XTCEXMLG and XTCEXMLN consist of an interlock element and mounting plate.
4 Also includes interlocking bridge (XTCEXLBB). The following control cables are integrated
for electrical interlock: K1M: A1–K2M: 21; K1M: 21–K2M: A1; K1M: A2–K2M: A2.

1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-73

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Electrical Interlocking Bridge

Parallel Link 456

For Use
with…

Pkg.
Qty. 1

Catalog Number

For Use
with…

Pkg.
Qty. 1

Catalog Number

XTCE007B–XTCE015B

20

XTCEXLBB

XTCEXPLKB

XTCE007B –XTCE015B

5

XTCEXPLKB

XTCEXPLK_

1
1

Star-Delta (Wye-Delta) Bridge

1
1

For Use
with…

Pkg.
Qty. 1

XTCE018C –XTCE032C

5

XTCEXPLKC

Catalog Number

XTCE040D –XTCE072D

1

XTCEXPLKD

XTCEXSDB

XTCE007B–XTCE015B

20

XTCEXSDBB 2

XTCE080F–XTCE170G

1

XTCEXPLKG

XTCE185L

1

XTCEXPLKL185

XTCEXSDB_

XTCE080F–XTCE170G

1

XTCEXSDBG

XTCE185L–XTCE400M

1

XTCEXSDB400

XTCE500M

1

XTCEXSDB500

1
1

XTCEXPLKL185

1
1
1

Component part of star-delta link kit (XTCEXSDL_). Commons
the three phases on the line side of shorting contactor.

1

Connector

1
1

XTCEXCNC

XTCEXTLA400

For Use
with…

Pkg.
Qty. 1

XTCE007B–XTCE032C

50

Terminal Lug Assembly

Catalog Number

For Use
with…

Pkg.
Qty. 1

Catalog Number

XTCEXCNC

XTCE185–XTCE225H

1

XTCEXTLA225A

XTCS250L–XTCS400M,
XTCE250L_–XTCE400M_

2

XTCEXTLA400

1

For connection of: round conductor, flexible and stranded,
flat strip conductor, with control circuit terminal. See Page
V5-T1-97 for terminal capacities.

1
1

For using one contactor per phase. Each package comes with
two links for line: load.

XTCEXCNG

XTCE040D–XTCE170G

10

XTCEXCNG

1

XGKE-GE

1

Contactor Labels
For Use
with…

Pkg.
Qty.

Catalog Number

XTC…

25

XGKE-GE 7

1
1
1
1
1
1
1

Notes
1 Orders must be placed in multiples of package quantity listed.
2 Frame B is toolless connection type.
3 For mechanically arranging contactors in combinations. Distance between contactors is 0 mm.
4 Fourth pole can be broken off: four-pole: Ith = 60A; three-pole: Ith = 50A.
5 AC-1 current carrying capacity of the contactor increases by a factor of 2.5. For XTCEXPLKL185, one shroud
is included for protection against accidental contact.
6 Protected against accidental contact in accordance with IEC 536.
7 Quantity 1 equals one sheet. One sheet contains 240 labels.

1
1
1
1
V5-T1-74

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

CI-K Basic Enclosures

CI-K Basic Enclosures 12

1

Dimensions in Inches (mm)
Width

Height

External
Depth

3.94 (100.0)

6.30 (160.0)

3.94 (100.0)

5.71 (145.0)

4.72 (120.0)

7.87 (200.0)

4.92 (125.0)

6.30 (160.0)

6.30 (160.0)

9.45 (240.0)

6.30 (160.0)

7.87 (200.0)

11.02 (280.0)

6.30 (160.0)

Internal
Depth

Internal Mounting Type

Pkg.
Qty.

2.87 (73.0)

With mounting rail

1

3.11 (79.0)

With mounting plate

1

Catalog Number
CI-K2X-100-TS-NA 3
CI-K2X-100-M-NA 3

4.65 (118.0)

With mounting rail

CI-K2X-145-TS-NA 3

4.88 (124.0)

With mounting plate

CI-K2X-145-M-NA 3

3.66 (93.0)

With mounting rail

3.86 (98.0)

With mounting plate

CI-K3X-125-M-NA 4

5.04 (128.0)

With mounting rail

CI-K3X-160-TS-NA 4

5.24 (133.0)

With mounting plate

5.04 (128.0)

With mounting rail

5.24 (133.0)

With mounting plate

5.04 (128.0)

With mounting rail

5.24 (133.0)

With mounting plate

1

CI-K3X-125-TS-NA 4

CI-K3X-160-M-NA
1

4

CI-K4X-160-TS-NA 4
CI-K4X-160-M-NA 4

1

CI-K5X-160-TS-NA 4
CI-K5X-160-M-NA 4

1
1
1
1
1
1
1
1

XTCEXCN_

Terminal Lug Kit—Set of Three Lugs

1

For Use
with…

Description

Pkg.
Qty. 5

Catalog Number

XTCE500M, XTCE570M

#4-500 kcmil two-phase Cu/Al 500A

1

XTCEXTL500

1
1

XTCEXTFB6_

1

Terminal Flat Bar 6
For Use
with…

Pkg.
Qty. 5

Catalog Number

XTCE500M–XTCE570M

1

XTCEXTFB650

XTCE750N–XTCE820N

1

XTCEXTFB820

1
1
1

For connection of a flat strip conductor. Comes with control
circuit terminal (consisting of three flat strip conductor terminals).

XTCEXTS_

1
1

Terminal Shroud
For Use
with…

Pkg.
Qty. 5

Catalog Number

XTCE185H–XTCE225H

1

XTCEXTS225

XTCE250L–XTCE400M

1

XTCEXTS400

XTCE500M–XTCE570M

1

XTCEXTS500

XTCE580N–XTCE650N

1

XTCEXTS650

XTCE750N–XTCEC10N

1

XTCEXTS820

1
1
1
1

Protection against direct contact with connection lugs when
touched vertically from the front.

1
1

Notes
1 Enclosure base RAL 9005, black/enclosure top only RAL 7035. light gray.
2 Degree of protection—IEC: IP65; UL/CSA: Type 1, 3R, 4X, 12, 13—indoor and outdoor use.
3 CI-K2X_: 4 x 1/2 inch knockouts.
4 CI-K3X_, CI-K4X_, CI-K5X_: Smooth overall with sharp corners.
5 Orders must be placed in multiples of package quantity listed.
6 Not UL listed.

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-75

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Renewal Parts
XTCERENC_

Replacement Coil—Frame C

Replacement Coil—Frame F 1

1

Voltage

Coil
Suffix

Catalog Number

Voltage

Coil
Suffix

Catalog Number

110/50 120/60

A

XTCERENCOILCA

110/50 120/60

A

XTCERENCOILFA

1

110–130 Vdc

AD

XTCERENCOILCAD

110–130 Vdc

AD

XTCERENCOILFAD

220/50 240/60

B

XTCERENCOILCB

220/50 240/60

B

XTCERENCOILFB

1

200–240 Vdc

BD

XTCERENCOILCBD

200–240 Vdc

BD

XTCERENCOILFBD

415/50 480/60

C

XTCERENCOILCC

415/50 480/60

C

XTCERENCOILFC

550/50 600/60

D

XTCERENCOILCD

550/50 600/60

D

XTCERENCOILFD

1

208/60

E

XTCERENCOILCE

208/60

E

XTCERENCOILFE

230/50

F

XTCERENCOILCF

230/50

F

XTCERENCOILFF

1

190/50 220/60

G

XTCERENCOILCG

190/50 220/60

G

XTCERENCOILFG

1

240/50 277/60

H

XTCERENCOILCH

240/50 277/60

H

XTCERENCOILFH

380/50 440/60

L

XTCERENCOILCL

380/50 440/60

L

XTCERENCOILFL

1

400/50

N

XTCERENCOILCN

400/50

N

XTCERENCOILFN

380/60

P

XTCERENCOILCP

380/60

P

XTCERENCOILFP

1

12/50 12/60

R

XTCERENCOILCR

12/50 12/60

R

XTCERENCOILFR

12–14 Vdc

RD

XTCERENCOILCRD

24/50 24/60

T

XTCERENCOILFT

24/50 24/60

T

XTCERENCOILCT

24–27 Vdc

TD

XTCERENCOILFTD

24–27 Vdc

TD

XTCERENCOILCTD

42/50 48/60

W

XTCERENCOILFW

42/50 48/60

W

XTCERENCOILCW

48–60 Vdc

WD

XTCERENCOILFWD

48–60 Vdc

WD

XTCERENCOILCWD

48/50

Y

XTCERENCOILFY

48/50

Y

XTCERENCOILCY

1

1
1
1
1

Replacement Coil—Frame G 2

1

Replacement Coil—Frame D

1

Voltage

Coil
Suffix

Catalog Number

Voltage

Coil
Suffix

Catalog Number

110/50 120/60

A

XTCERENCOILDA

100–120V 50/60

A

XTCERENCOILGA

1

110–130 Vdc

AD

XTCERENCOILDAD

110–130 Vdc

AD

XTCERENCOILGAD

220/50 240/60

B

XTCERENCOILDB

190–240V 50/60

B

XTCERENCOILGB

BD

XTCERENCOILGBD

1

200–240 Vdc

BD

XTCERENCOILDBD

200–240 Vdc

1

415/50 480/60

C

XTCERENCOILDC

480–500V 50/60

C

XTCERENCOILGC

550/50 600/60

D

XTCERENCOILDD

380–440V 50/60

L

XTCERENCOILGL

1

208/60

E

XTCERENCOILDE

4/50 24/60

T

XTCERENCOILGT

230/50

F

XTCERENCOILDF

24–27 Vdc

TD

XTCERENCOILGTD

1

190/50 220/60

G

XTCERENCOILDG

42–48V 50/60

W

XTCERENCOILGW

240/50 277/60

H

XTCERENCOILDH

48–60 Vdc

WD

XTCERENCOILGWD

380/50 440/60

L

XTCERENCOILDL

1
1
1
1
1
1

400/50

N

XTCERENCOILDN

380/60

P

XTCERENCOILDP

12/50 12/60

R

XTCERENCOILDR

12–14 Vdc

RD

XTCERENCOILDRD
XTCERENCOILDT

24/50 24/60

T

24–27 Vdc

TD

XTCERENCOILDTD

42/50 48/60

W

XTCERENCOILDW

48–60 Vdc

WD

XTCERENCOILDWD

48/50

Y

XTCERENCOILDY

Notes
1 Frame F replacement coils can only be used with contactors having the following date codes:
DC coils, 2706 or later; AC coils, 4706 or later.
2 Frame G replacement coils can only be used with contactors having date codes of 2706 or
later.

1
1
V5-T1-76

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

Replacement Coil—Frame H

Replacement Contact Kit
For Use with…

Catalog Number

XTCE040D–XTCE065D

XTCERENCONTACTD

XTCE250L

XTCERENCONTACTL

XTCERENCOILHB

XTCE300M–XTCE570M

XTCERENCONTACTM

XTCERENCOILHC

XTCE085F–XTCE095F

XTCERENCONTACTF

L

XTCERENCOILHL

XTCE115G–XTCE150G

XTCERENCONTACTG

24V 50/60Hz

T

XTCERENCOILHT

42–48V 50/60Hz

W

XTCERENCOILHW

110–130 Vdc

AD

XTCERENCOILHAD

200–240 Vdc

BD

XTCERENCOILHBD

24–27 Vdc

TD

XTCERENCOILHTD

48–60 Vdc

WD

XTCERENCOILHWD

Voltage

Coil
Suffix

Catalog Number

100–120V 50/60 Hz

A

XTCERENCOILHA

190–240V 50/60 Hz

B

480–500V 50/60 Hz

C

380–440V 50/60 Hz

Replacement Coil—Frame L 1

1
1
1
1
1

Replacement Vacuum Tube Assembly
For Use with…

Catalog Number

XTCE580N

XTCERENVACT580

XTCE650N

XTCERENVACT650

XTCE750N

XTCERENVACT750

XTCE820N

XTCERENVACT820

1
1
1
1

Replacement Arc Chamber

Voltage

Coil
Suffix

Catalog Number

110–250 Vac/Vdc

A

XTCERENCOILLA

250–500V 40–60

C

XTCERENCOILLC

24–48 Vdc

TD

XTCERENCOILLTD

48–110 Vac/Vdc

Y

XTCERENCOILLY

For Use with…

Catalog Number

XTCE250L

XTCERENARC250

XTCE300M

XTCERENARC300

XTCE400M

XTCERENARC400

XTCE500M–XTCE570M

XTCERENARC500

1
1
1
1

Note
1 Electronic modules including coils.

Replacement Coil—Frame L, S-Series
Voltage

Coil
Suffix

Catalog Number

110–120V 50/60 Hz

A

XTCSRENCOILLA

220–240V 50/60 Hz

B

XTCSRENCOILLB

Replacement Coil—Frame M

1.1

1
1
1

1

1

Voltage

Coil
Suffix

Catalog Number

110–250 Vac/Vdc

A

XTCERENCOILMA

250–500V 40–60

C

XTCERENCOILMC

24–48 Vdc

TD

XTCERENCOILMTD

48–110 Vac/Vdc

Y

XTCERENCOILMY

1
1
1
1

Replacement Coil—Frame M, S-Series
Voltage

Coil
Suffix

Catalog Number

110–120V 50/60 Hz

A

XTCSRENCOILMA

220–240V 50/60 Hz

B

XTCSRENCOILMB

1
1
1

Replacement Coil—Frame N 1
Voltage

Coil
Suffix

Catalog Number

110–250 Vac/Vdc

A

XTCERENCOILNA

250–500V 40–60

C

XTCERENCOILNC

48–110 Vac/Vdc

Y

XTCERENCOILNY

1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-77

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Technical Data and Specifications
XT Contactors—Frame B
Description

XTCE007B

XTCE009B

XTCE012B

XTCE015B

IEC/EN 60947, VDE 0660,
UL, CSA, CCC, RoHS

IEC/EN 60947, VDE 0660,
UL, CSA, CCC, RoHS

IEC/EN 60947, VDE 0660,
UL, CSA, CCC, RoHS

IEC/EN 60947, VDE 0660,
UL, CSA, CCC, RoHS

AC operated

0.23 [0.51]

0.23 [0.51]

0.23 [0.51]

0.23 [0.51]

DC operated

0.28 [0.62]

0.28 [0.62]

0.28 [0.62]

0.28 [0.62]

10,000,000

10,000,000

10,000,000

10,000,000

AC operated

9000

9000

9000

5000

DC operated

9000

9000

9000

5000

See Curves,
Page V5-T1-111

See Curves,
Page V5-T1-111

See Curves,
Page V5-T1-111

See Curves,
Page V5-T1-111

General
Standards
Weights in kg [lb]

Mechanical life—operations
Mechanical operating frequency (ops/hr)

1

Electrical life

1

Electrical operating frequency (ops/hr)—see Curves, Page V5-T1-111

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

AC-1; 400V I e

800

800

800

800

AC-3; 400V I e

1000

1000

1000

1000

AC-4; 400V I e

300

300

300

300

Climatic proofing

3

3

3

3

Insulation voltage (U i) Vac

690

690

690

690

Impulse withstand voltage (U imp) Vac

8000

8000

8000

8000

Operational voltage (U e) Vac

690

690

690

690

Safe isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and contacts (Vac)

400

400

400

400

Between contacts (Vac)

400

400

400

400

112

112

144

155

220/230V

70

90

120

124

380/400V

70

90

120

124

500V

50

70

100

100

660/690V

40

50

70

70

400V; gG/gL 500V

20

20

20

20

690V; gG/gL 690V

16

16

20

20

400V; gG/gL 500V

35

35

35

63

690V; gG/gL 690V

20

20

20

50

Degree of protection

IP20

IP20

IP20

IP20

Protection against direct contact when actuated from front (IEC 536)

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Making capacity up to 690V (amps) 1
Breaking capacity (amps)

Short-circuit protection rating maximum fuse
Type 2 coordination 2

Type 1 coordination 2

Terminal capacity main cable—screw terminals

1

Solid (mm2)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1

Flexible with ferrule (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1
1
1
1

Terminal capacity control circuit cable—screw terminals
Solid (mm2)

Notes
1 Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated.
2 IEC 60947 Standard.
3 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30.

V5-T1-78

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

XT Contactors—Frame B, continued
Description

1

XTCE007B

XTCE009B

XTCE012B

XTCE015B

Flexible with ferrule (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

M3.5

M3.5

M3.5

M3.5

1
1

1

General, continued

Main cable and control circuit cable connection screw/bolt

1

Tightening torque
Nm

1.2

1.2

1.2

1.2

Lb-in

10.6

10.6

10.6

10.6

1

Main and control circuit cable—screw terminals

Size 2

Size 2

Size 2

Size 2

Pozidriv screwdriver

0.8 x 5.5

0.8 x 5.5

0.8 x 5.

0.8 x 5.5

1

Standard screwdriver

1x6

1x6

1x6

1x6

Solid (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Flexible (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

Solid (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Flexible (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

1 x (0.75–2.5)
1 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

Tools

1

Terminal capacity main circuit cable—spring cage terminals

1
1
1
1

Terminal capacity control circuit cable—spring cage terminals

1
1
1
1

Tools

1

Main and control circuit cable—spring cage terminals
Stripping length (mm)

10

10

10

10

Screwdriver blade width (mm)

3.5

3.5

3.5

3.5

Mounting position, AC and DC operated

1
1

30°
90

°

°
90

90

1

180°

°

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1
1
1

Ambient temperature
Open

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

Enclosed

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

Ambient storage temperature

1
1
1

Environmental

1

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Main contact—NO contact

10g

10g

10g

10g

Auxiliary contact—NO contact

7g

7g

7g

7g

Auxiliary contact—NC contact

5g

5g

5g

5g

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

1
1
1
V5-T1-79

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

XT Contactors—Frames C–D
Description

XTCE018C

XTCE025C

XTCE032C

XTCE040D

XTCE050D

XTCE065D, XTCE072D

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

AC operated

0.42 [0.93]

0.42 [0.93]

0.42 [0.93]

0.9 [2.0]

0.9 [2.0]

0.9 [2.0]

DC operated

0.48 [1.06]

0.48 [1.06]

0.48 [1.06]

1.1 [2.4]

1.1 [2.4]

1.1 [2.4]

10,000,000

10,000,000

10,000,000

10,000,000

10,000,000

10,000,000

AC operated

5000

5000

5000

5000

5000

5000

DC operated

5000

5000

5000

5000

5000

5000

General
Standards

1
1
1
1
1
1
1
1
1

Weights in kg [lb]

Mechanical life—operations
Mechanical operating frequency (ops/hr)

Electrical mechanical operating frequency (ops/hr)—
see Curves, Page V5-T1-111
AC-1; 400V I e

800

800

800

800

800

800

AC-3; 400V I e

800

800

800

800

800

800

AC-4; 400V I e

300

300

300

300

300

300

2

2

2

2

2

2

Climatic proofing
Insulation voltage (U i) Vac

690

690

690

690

690

690

1

Impulse withstand voltage (U imp) Vac

8000

8000

8000

8000

8000

8000

Operating voltage (U e) Vac

690

690

690

690

690

690

1

Safe isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and contacts (Vac)

440

440

440

440

440

440

1

Between contacts (Vac)

238

440

440

440

440

440

1

238

350

384

560

700

910

Breaking capacity (amps)

Making capacity (amps)

1

220/230V

170

250

320

400

500

650

380/400V

170

250

320

400

500

650

1

500V

170

250

320

400

500

650

660/690V

120

150

180

250

320

370

400V; gG/gL 500V

25

35

63

63

80

125

690V; gG/gL 690V

25

35

35

50

63

80

63

100

125

125

160

250
100

1
1
1
1

Short-circuit protection rating maximum fuse (amps)
Type 2 coordination 1

Type 1 coordination 1
400V; gG/gL 500V

1

50

50

63

80

80

Degree of protection

IP00

IP00

IP00

IP00

IP00

IP00

1

Protection against direct contact when
actuated from front (IEC 536)

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Solid (mm2)

1

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

Flexible with ferrule (mm2)

1

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

1 x (2.5–35)
2 x (2.5–25)

1 x (2.5–35)
2 x (2.5–25)

1 x (2.5–35)
2 x (2.5–25)

Stranded (mm2)

1 x 16

1 x 16

1 x 16

1 x (16–50)
2 x (16–35)

1 x (16–50)
2 x (16–35)

1 x (16–50)
2 x (16–35)

1

Solid or stranded (AWG)

18–6

18–6

18–6

12–2

12–2

12–2

—

—

—

2 x (6 x 9 x 0.8)

2 x (6 x 9 x 0.8)

2 x (6 x 9 x 0.8)

1

1
1
1

690V; gG/gL 690V

Terminal capacity main cable—screw terminals

Flat conductor
(number of segments x width x thickness) (mm)

Notes
1 IEC 60947 Standard.
2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.

V5-T1-80

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

XT Contactors—Frames C–D, continued
Description

1

XTCE018C

XTCE025C

XTCE032C

XTCE040D

XTCE050D

XTCE065D, XTCE072D

M5

M5

M5

M6

M6

M6

Nm

3

3

3

3.3

3.3

3.3

Lb-in

26.6

26.6

26.6

29.2

29.2

29.2

1 x (0.75–4)
2 x (0.75–4)

1 x (0.75–4)
2 x (0.75–4)

1 x (0.75–4)
2 x (0.75–4)

1 x (0.75–4)
2 x (0.75–4)

1 x (0.75–4)
2 x (0.75–4)

1 x (0.75–4)
2 x (0.75–4)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

18–14

18–14

Control circuit cable connection screw/bolt

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

Nm

1.2

1.2

1.2

1.2

1.2

1.2

Lb-in

10.6

10.6

10.6

10.6

10.6

10.6

Size 2

Size 2

Size 2

Size 2

Size 2

Size 2

Pozidriv screwdriver

0.8 x 5.5

0.8 x 5.5

0.8 x 5.5

0.8 x 5.5

0.8 x 5.5

0.8 x 5.5

Standard screwdriver

1x6

1x6

1x6

1x6

1x6

1x6

Solid (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Flexible (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

18–14

18–14

1

10

10

10

10

10

10

3.5

3.5

3.5

3.5

3.5

3.5

1

General, continued
Main cable connection screw/bolt

1

Tightening torque

1

Terminal capacity control circuit cable—screw terminals
Solid (mm2)

1
1
1
1

Tightening torque

1
1

Tools
Main and control circuit cable—screw terminals

1
1

Terminal capacity control circuit cable—spring cage terminals

1

Tools

1

Main and control circuit cable—spring cage terminals
Stripping length (mm)
Screwdriver blade width (mm)
Mounting position, AC and DC operated

°
90

°

1
1

180°

180°

°

°

°
90

90

90

1

30° 30°

30°
90

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1
1
Ambient temperature
Open

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

Enclosed

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

Ambient storage temperature

1
1
1

Environmental

1

Mechanical shock resistance
(IEC/EN 60068-2-27)

1

Main contact—NO Contact

10

10

10

10

1

1

Auxiliary contact—NO Contact

7

7

7

7

7

7

Auxiliary contact—NC Contact

5

5

5

5

5

5

III/3

III/3

III/3

III/3

III/3

III/3

Overvoltage category/pollution degree

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-81

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

XT Contactors—Frames F–G
Description
Standards

1
1

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE170G

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

IEC/EN 60947,
VDE 0660, UL, CSA,
CCC, RoHS

General

Weights in kg [lb]
AC operated

2 [4.41]

2 [4.41]

2 [4.41]

2 [4.41]

2 [4.41]

DC operated

2.1 [4.63]

2.1 [4.63]

2.1 [4.63]

2.1 [4.63]

2.1 [4.63]

10,000,000

10,000,000

10,000,000

10,000,000

10,000,000

AC operated

3600

3600

3600

3600

3600

DC operated

3600

3600

3600

3600

3600

AC-1; 400V I e

800

800

800

800

800

1

AC-3; 400V I e

800

800

800

800

800

AC-4; 400V I e

300

300

300

300

300

1

Climatic proofing

2

2

2

2

2

1
1
1
1

Mechanical life—operations
Mechanical operating frequency (ops/hr)

Electrical mechanical operating frequency (ops/hr)—
see Curves, Page V5-T1-111

Insulation voltage (U i) Vac

690

690

690

690

690

1

Impulse withstand voltage (U imp) Vac

8000

8000

8000

8000

8000

Operational voltage (U e) Vac

690

690

690

690

690

1

Safe isolation to VDE 0106 Part 101 and Part 101/A1

1
1
1
1
1

Between coil and contacts (Vac)

690

690

690

690

690

Between contacts (Vac)

690

690

690

690

690

1120

1330

1610

2100

2100

Making capacity (amps)
Breaking capacity (amps)
220/230V

800

950

1150

1500

1500

380/400V

800

950

1150

1500

1500

500V

800

950

1150

1500

1500

660/690V

650

800

1100

1200

1320

1000V

—

—

—

—

—

Short-circuit protection rating maximum fuse

1

Type 2 coordination 1
400V; gG/gL 500V

160

160

250

25

400

1

690V; gG/gL 690V

160

160

25

250

25

1
1
1
1
1
1
1
1
1
1
1

Type 1 coordination 1
400V; gG/gL 500V

250

25

250

250

400

690V; gG/gL 690V

200

200

250

250

250

Degree of protection

IP00

IP00

IP00

IP00

IP00

Protection against direct contact when actuated from front (IEC 536)

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Solid (mm2)

—

—

—

—

—

Flexible with ferrule (mm2)

1 x (10–95)
2 x (10–70)

1 x (10–95)
2 x (10–70)

1 x (10–95)
2 x (10–70)

1 x (10–95)
2 x (10–70)

1 x (10–95)
2 x (10–70)

Stranded (mm2)

1 x (10–95)
2 x (10–20)

1 x (10–95)
2 x (10–20)

1 x (10–95)
2 x (10–20)

1 x (10–95)
2 x (10–20)

1 x (10–95)
2 x (10–20)

Flat conductor
(number of segments x width x thickness) (mm)

2 x (6 x 16 x 0.8)

2 x (6 x 16 x 0.8)

2 x (6 x 16 x 0.8)

2 x (6 x 16 x 0.8)

2 x (6 x 16 x 0.8)

Solid or stranded (AWG)

8–3/0

8–3/0

8–3/0

8–3/0

8–3/0

M10

M10

M10

M10

M10

Nm

14

14

14

14

14

Lb-in

123.9

123.9

123.9

123.9

123.9

Terminal capacity main cable—screw terminals

Main cable connection screw/bolt
Tightening torque

Notes
1 IEC 60947 Standard.
2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.

V5-T1-82

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

XT Contactors—Frames F–G, continued
Description

XTCE080F

XTCE095F

XTCE115G

XTCE150G

1

XTCE170G

1

General, continued
Terminal capacity control circuit cable—screw terminals

1

Solid (mm2)

1 x (0.75–4)
1 x (0.75–4)

1 x (0.75–4)
1 x (0.75–4)

1 x (0.75–4)
1 x (0.75–4)

1 x (0.75–4)
1 x (0.75–4)

1 x (0.75–4)
1 x (0.75–4)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

18–14

M3.5

M3.5

M3.5

M3.5

M3.5

1

Nm

1.2

1.2

1.2

1.2

1.2

Lb-in

10.6

10.6

10.6

10.6

10.6

Control circuit cable connection screw/bolt

1

Tightening torque

1
1

Tools
Main circuit cable—screw terminals
Hexagon socket-head spanner (mm)

5

5

5

5

5

1
1

Control circuit cable—screw terminals
Pozidriv screwdriver

Size 2

Size 2

Size 2

Size 2

Size 2

Standard screwdriver

1 x 6, 0.8 x 5.5

1 x 6, 0.8 x 5.5

1 x 6, 0.8 x 5.5

1 x 6, 0.8 x 5.5

1 x 6, 0.8 x 5.5

Solid (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Flexible (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

18–14

1

Terminal capacity control circuit cable—spring cage terminals

1
1
1
1

Tools
Control circuit cable—spring cage terminals

1

Stripping length (mm)

10

10

10

10

10

Screwdriver blade width (mm)

3.5

3.5

3.5

3.5

3.5

1

Mounting position, AC and DC operated

30°

30°

30°

90

°

1
1

180°

180°

°

°

90

90

°

30°
90

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1
1
Ambient temperature
Open

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

Enclosed

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–25 to 40°C
[–13 to 104°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

Ambient storage temperature

1
1
1

Environmental
Mechanical shock resistance
(IEC/EN 60068-2-27)

1

Half-sinusoidal shock 10 ms
Main contact—NO contact

1

10g

10g

10g

10g

1

10g

Auxiliary contact—NO contact

7g

7g

7g

7g

7g

Auxiliary contact—NC contact

5g

5g

5g

5g

5g

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

III/3

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-83

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

XT Contactors—Frames H–M
Description

XTCE185H

XTCE225H

XTCE250L,
XTCS250L

XTCE300L,
XTCS300L

XTCE400M
XTCS400M

XTCE500M,
XTCS500M

XTCE570M
XTCS570M

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

IEC/EN 60947,
VDE 0660,
UL, CSA

General
Standards

Weights in kg [lb]

3.2 [7.1]

3.2 [7.1]

6.5 [14.3]

6.5 [14.3]

8 [18]

8 [18]

8 [18]

Mechanical life—operations

10,000,000

10,000,000

10,000,000

10,000,000

7,000,000

7,000,000

7,000,000

Mechanical operating frequency (ops/hr)
AC operated
DC operated

3000

3000

3000

3000

2000

2000

2000

3000

3000

3000

3000

2000

2000

2000

1

Mechanical operating frequency (ops/hr)
Climatic proofing

2

2

2

2

2

2

2

1

Insulation voltage (U i) Vac

1000

1000

1000

1000

1000

1000

1000

Impulse withstand voltage (U imp) Vac

8000

8000

8000

8000

8000

8000

8000

Operating voltage (U e) Vac

1000

1000

1000

1000

1000

1000

1000

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Safe isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and contacts (Vac)
Between contacts (Vac)
Making capacity (amps)
Breaking capacity (amps)
Between coil and contacts (Vac)
220/230V

See Page V5-T1-93

500

500

500

500

500

500

500

500

500

500

500

500

500

500

2700

2700

3000

3600

5500

5500

5500

2250

2250

2500

3000

5000

5000

5000

380/400V

2250

2250

2500

3000

5000

5000

5000

500V

2250

2250

2500

3000

5000

5000

5000

660/690V

2250

2250

2500

3000

5000

5000

5000

1000V

760

760

760

950

950

950

950

500

Short-circuit protection rating maximum fuse
Type 2 coordination 1
400V; gG/gL 500V

315

315

315

315

500

500

690V; gG/gL 690V

250

250

315

315

500

500

500

1000V; gG/gL 1000V

160

160

160

160

200

200

200

IP00

IP00

IP00

IP00

IP00

IP00

IP00

Degree of protection
Protection against direct contact when
actuated from front (IEC 536)
Main cable cross-section
Flexible with cable lug (mm2)

Finger and back-of-hand proof with terminal shroud or terminal block

50–185

50–185

50–240

50–240

50–240

50–240

50–240

Stranded with cable lug (mm2)

50–185

70–185

70–240

70–240

70–240

70–240

70–240

Solid or stranded (AWG)

1/0–350 kcmil

2/0–250 kcmil

1/0–250 kcmil

2/0–500 kcmil

1/0–250 kcmil

1/0–250 kcmil

1/0–250 kcmil

Flat conductor (mm)

3

3

3

3

3

3

3

Busbar—width in mm

32

32

25

25

25

30

30

M10

M10

M10

M10

M10

M10

M10

Main cable connection screw/bolt
Tightening torque
Nm
Lb-in

24

24

24

24

2

2

2

213

213

213

213

213

213

213

Notes
1 IEC 60947 Standard.
2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
3 Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks.

1
1
1
V5-T1-84

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

XT Contactors—Frames H–M, continued

1

XTCE185H

XTCE225H

XTCE250L,
XTCS250L

XTCE300L,
XTCS300L

XTCE400M
XTCS400M

XTCE500M,
XTCS500M

XTCE570M
XTCS570M

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Solid or stranded (AWG)

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

1.2

1.2

1.2

1.2

1.2

1.2

1.2

10.6

10.6

10.6

10.6

10.6

10.6

10.6

1

16 mm

16 mm

16 mm

16 mm

16 mm

16 mm

16 mm

1

Size 2

Size 2

Size 2

Size 2

Size 2

Size 2

Size 2

Description

1

General, continued
Control circuit cable cross-sections
Solid (mm2)

Control circuit cable connection screw/bolt
Tightening torque
Nm
Lb-in
Tools
Main cable wrench
Control circuit cable pozidriv screwdriver
Mounting position, AC and DC operated

30°

30°

90

°

90°

1
1
1
1

30°

30°

90°

1
1

180°

°

90

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1
1

Ambient temperature

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

Ambient storage temperature

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

1
1
1

Environmental
Mechanical shock
Resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms
Main contact—NO contact

1
10g

10g

10g

10g

10g

10g

10g

Auxiliary contact—NO contact

10g

10g

10g

10g

10g

10g

10g

Auxiliary contact—NC contact

8g

8g

8g

8g

8g

8g

8g

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

III/3

III/3

III/3

Switching capacity, kVAR 1
Individual compensation
230V

1
1
1
1

—

—

—

—

—

—

—

400/420/440V

—

—

—

—

—

—

—

525V

220

220

—

307

—

—

—

690V

133

133

—

177

—

—

—

1
1

Group compensation, with choke
230V

—

—

100

—

160

160

160

400/420/440V

—

—

190

—

280

280

280

525V

—

—

260

—

370

370

370

690V

—

—

340

—

480

480

480

1

1
1

Note
1 When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high
inrush current peaks. This corresponds to an air-cored coil with five windings and a coil diameter of approximately 140 mm. The conductor
cross-section must be selected according to the rated current per phase.

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-85

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

XT Contactors—Frames N–R
Description

XTCE580N

XTCE650N

XTCE750N,
XTCE820N

XTCEC10N

XTCEC14P

XTCEC16R,
XTCEC20R

IEC/EN 60947,
VDE 0660, UL, CSA

IEC/EN 60947,
VDE 0660, UL, CSA

IEC/EN 60947,
VDE 0660, UL, CSA

IEC/EN 60947,
VDE 0660, UL, CSA

IEC/EN 60947,
VDE 0660, UL, CSA

IEC/EN 60947,
VDE 0660, UL, CSA

General

1

Standards

1

Weights in kg [lb]

15 [33]

15 [33]

15 [33]

15 [33]

15, [33]

32 [70]

Mechanical life—operations

5,000,000

5,000,000

5,000,000

5,000,000

5,000,000

5,000,000

1

Mechanical operating frequency (ops/hr)
AC operated

1000

1000

1000

1000

1000

1000

DC operated

1000

1000

1000

1000

1000

1000

1
1

Maximum operating frequency (ops/hr)

See Page V5-T1-113

Climatic proofing

2

2

2

2

2

2

1

Insulation voltage (Ui) Vac

1000

1000

1000

1000

1000

1000

Impulse withstand voltage (Uimp) Vac

8000

8000

8000

8000

8000

8000

1

Operating voltage (Ue) Vac

1000

1000

1000

1000

1000

1000

1

Safe isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and contacts (Vac)

500

500

500

500

500

500

Between contacts (Vac)

500

500

500

500

500

500

Making capacity (amps)

7800

7800

9840

9840

9840

19000, 9840

220/230V

6500

6500

8200

8200

8200

16000, 8200

1

380/400V

6500

6500

8200

8200

8200

16000, 8200

500V

6500

6500

8200

8200

8200

16000, 8200

1

660/690V

6500

6500

8200

8200

8200

16000, 8200

1000V

4350

4350

5800

5800

5800

5800

1
1

1

Breaking capacity (amps)

Short-circuit protection rating maximum fuse

1

Type 2 coordination 1
400V; gG/gL 500V

630

630

630

630

—

—

1

690V; gG/gL 690V

630

630

630

630

—

—

1000V; gG/gL 1000V

500

500

630

630

—

—

1

Type 1 coordination 1
400V; gG/gL 500V

1000

1000

1200

1200

—

—

690V; gG/gL 690V

1000

1000

1200

1200

—

—

1000V; gG/gL 1000V

630

630

800

800

—

—

1
1

Degree of protection

IP00

IP00

IP00

IP00

IP00

IP00

1

Protection against direct contact when actuated
from front (IEC 536)

Finger and back-ofhand proof with
terminal shroud or
terminal block

Finger and back-ofhand proof with
terminal shroud or
terminal block

Finger and back-ofhand proof with
terminal shroud or
terminal block

Finger and back-ofhand proof with
terminal shroud or
terminal block

Finger and back-ofhand proof with
terminal shroud or
terminal block

Finger and back-ofhand proof with
terminal shroud or
terminal block

50-240

50-240

50-240

50-240

50-240

50-240
70-240

1
1
1
1
1
1
1
1
1

Main cable cross-section
Flexible with cable lug (mm2)
Stranded with cable lug (mm2)

70-240

70-240

70-240

70-240

70-240

Solid or stranded (AWG)

2/0–500 kcmil

2/0–500 kcmil

2/0–500 kcmil

2/0–500 kcmil

2/0–500 kcmil

2/0–500 kcmil

Flat conductor (mm)

3

3

3

3

3

3

Busbar—width in mm

50

50

50

50

50

50

M10

M10

M12

M12

M12

M1

Main cable connection screw/bolt
Tightening torque
Nm

24

24

35

35

35

35

Lb-in

213

213

311

311

311

311

Notes
1 IEC 60947 Standard.
2 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60 068-2-30.
3 Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks.

V5-T1-86

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

XT Contactors—Frames N–R, continued
Description

XTCE580N

XTCE650N

XTCE750N, XTCE820N

XTCEC10N

XTCEC14P

XTCEC16R, XTCEC20R

1
1

General, continued
Control circuit cable cross-sections

1

Solid (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1

Solid or stranded (AWG)

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

M3.5

M3.5

M3.5

M3.5

M3.5

M3.5

1

Nm

1.2

1.2

1.2

1.2

1.2

1.2

Lb-in

10.6

10.6

10.6

10.6

10.6

10.6

Main cable wrench

16 mm

16 mm

18 mm

18 mm

18 mm

18 mm

Control circuit cable pozidriv screwdriver

Size 2

Size 2

Size 2

Size 2

Size 2

Size 2

Control circuit cable connection screw/bolt

1

Tightening torque

1
1

Tools

Mounting position, AC and DC operated

30°

30°

°
90

30°
90°

1
30°

1

90°

°

90

1

180°

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1
1
Ambient temperature

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

–25 to 60°C
[–13 to 140°F]

Ambient storage temperature

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

–40 to 80°C
[–40 to 176°F]

1
1

Environmental

1

Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock 10 ms (g)
Main contact—NO contact

10

10

10

10

10

10

Auxiliary contact—NO contact

10

10

10

10

10

10

Auxiliary contact—NC contact

8

8

8

8

8

8

III/3

III/3

III/3

III/3

III/3

III/3

230V

175

—

—

—

—

—

400/420/440V

300

—

—

—

—

—

525V

400

—

—

—

—

—

690V

300

—

—

—

—

—

Overvoltage category/pollution degree

1
1
1

Switching capacity, kVAR 1

1

Individual compensation

1
1
1

Note
1 When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high
inrush current peaks. This corresponds to an air-cored coil with five windings and a coil diameter of approximately 140 mm. The conductor
cross-section must be selected according to the rated current per phase.

1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-87

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Coil Data—Frames B–D
Description

XTCE007B

XTCE009B

XTCE012B,
XTCF020B

XTCE032C

XTCE040D

XTCE050D

XTCE065D,
XTCE072D

AC operated

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

DC operated

0.8–1.1 1

0.8–1.1 1

0.8–1.1 1

0.8–1.1 1

0.7–1.2 2

0.7–1.2 2

0.7–1.2 2

0.7–1.2 2

0.7–1.2 2

0.7–1.2 2

Dropout (x Uc)
AC operated

0.3–0.6

0.3–0.6

0.3–0.6

0.3–0.6

0.3–0.6

0.3–0.6

0.3–0.6

0.3–0.6

0.3–0.6

0.3–0.6

DC operated

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

1

AC operated
Single-voltage coil 50 Hz

1

XTCE025C

Pickup (x Uc)

Power Consumption of the Coil at Cold State and 1.0 x Uc

1

XTCE018C

Voltage Tolerance

1
1

XTCE015B

Pickup VA

24

24

24

24

52

52

52

149

149

149

Pickup W

19

19

19

19

40

40

40

80

80

80

Sealing VA

3.4

3.4

3.4

3.4

7.1

7.1

7.1

16

16

16

Sealing W

1.2

1.2

1.2

1.2

2.1

2.1

2.1

4.3

4.3

4.3

Single-voltage coil 60 Hz

1

Pickup VA

30

30

30

30

67

67

67

178

178

178

Pickup W

23

23

23

23

50

50

50

117

117

117

1

Sealing VA

4.4

4.4

4.4

4.4

8.7

8.7

8.7

19

19

19

Sealing W

1.4

1.4

1.4

1.4

2.6

2.6

2.6

5.3

5.3

5.3

Pickup VA

27
25

27
25

27
25

27
25

62
58

62
58

62
58

168
154

168
154

168
154

Pickup W

22
21

22
21

22
21

22
21

48
43

48
43

48
43

120
43

120
43

120
43

Sealing VA

4.2
3.3

4.2
3.3

4.2
3.3

4.2
3.3

9.1
6.5

9.1
6.5

9.1
6.5

22
14

22
14

22
14

Sealing W

1.4
1.2

1.4
1.2

1.4
1.2

1.4
1.2

2.5
2

2.5
2

2.5
2

5.3
4.3

5.3
4.3

5.3
4.3

Pickup W

3

3

4.5

4.5

12 at 24V

12 at 24V

12 at 24V

24 at 24V

24 at 24V

24 at 24V

Sealing W

3

3

4.5

4.5

0.5 at 24V

0.5 at 24V

0.5 at 24V

0.5 at 24V

0.5 at 24V

0.5 at 24V

100

100

100

100

100

100

100

100

100

100

1
1
1
1
1
1

50/60 Hz

DC operated

1

Duty factor (%DF)

1

Main contact

1
1
1
1
1
1
1
1
1
1

Switching Time at 100% Uc (Approximate Values)

AC operated
Closing delay (ms)

<21

<21

<21

<21

<22

<22

<22

<18

<18

<18

Opening delay (ms)

<18

<18

<18

<18

<14

<14

<14

<13

<13

<13

DC operated
Closing delay (ms)

<31

<31

<31

<31

<47

<47

<47

<54

<54

<54

Opening delay (ms)

<12

<12

<12

<12

<30

<30

<30

<24

<24

<24

10

10

10

10

10

10

10

10

10

10

Arcing time (ms)

Electromagnetic Compatibility (EMC)
Emitted interference

To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1

Noise immunity

To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1 To EN-60947-1

Notes
1 0.7–1.3 without additional auxiliary contact modules and ambient temperature +40°C [104°F].
2 Coil Suffix TD: U
min 24 Vdc/Umax 27 Vdc.
Coil Suffix WD: Umin 48 Vdc/Umax 60 Vdc.
Coil Suffix AD: Umin 110 Vdc/Umax 130 Vdc.
Coil Suffix BD: Umin 200 Vdc/Umax 240 Vdc.
Example:
Uc = 0.7 x Umin—1.2 x Umax
Uc = 0.7 x 24V—1.2 x 27 Vdc

V5-T1-88

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Coil Data—Frames F–G
Description

XTCE80F

XTCE95F

XTCE115G

XTCE150G

1

XTCE170G

1

Voltage Tolerance
Pickup (x Uc)
AC operated

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

DC operated

0.7–1.2 1

0.7–1.2 1

0.7–1.2 1

0.7–1.2 1

0.7–1.2 1

1
1

Dropout (x Uc)
AC operated

0.3–0.6

0.3–0.6

0.25–0.6

0.25–0.6

0.25–0.6

DC operated

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

0.15–0.6

1
1

Power Consumption of the Coil at Cold State and 1.0 x Uc
AC operated
Single-voltage coil 50 Hz

1

Pickup VA

310

310

180

180

180

Pickup W

165

165

130

130

130

Sealing VA

26

26

3.1

3.1

3.1

Sealing W

5.8

5.8

2.1

2.1

2.1

1

Pickup VA

345

345

170

170

170

1

1

Single-voltage coil 60 Hz

1

Pickup W

190

190

130

130

130

Sealing VA

30

30

3.1

3.1

3.1

Sealing W

7.1

7.1

2.1

2.1

2.1

1

Pickup VA

372

328

170

170

170

1

50/60 Hz

1

Pickup W

190

190

130

130

130

Sealing VA

37.1

22.6

3.1

3.1

3.1

Sealing W

7.5

6.1

2.1

2.1

2.1

1

90 at 24V

90 at 24V

149 at 24V

149 at 24V

149 at 24V

1

DC operated
Pickup W
Sealing W
Duty factor (%DF)

1.3 at 24V

1.3 at 24V

2.1 at 24V

2.1 at 24V

2.1 at 24V

100

100

100

100

100

1
1

Switching Time at 100% Uc (Approximate Values)
Main contact

1

AC operated
Closing delay (ms)

<20

<20

<33

<33

<33

Opening delay (ms)

<14

<14

<41

<41

<41

1

Closing delay (ms)

<45

<45

<35

<35

<35

1

Opening delay (ms)

DC operated

<34

<34

<30

<30

<30

Arcing time (ms)

15

15

15

15

15

Permissible residual current with actuation of
A1–A2 by the electronics (with 0 signal) (mA)

<1

<1

<1

<1

<1

Emitted interference

To EN60947-1

To EN60947-1

To EN60947-1

To EN60947-1

To EN60947-1

Noise immunity

To EN60947-1

To EN60947-1

To EN60947-1

To EN60947-1

To EN60947-1

1
1
1

Electromagnetic Compatibility (EMC)

1
1

Note
1 At 24V: 0.7–1.3 without additional auxiliary contact modules and ambient temperature +40°C [104°F].

1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-89

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Coil Data—Frames H–R
XTCE185H, XTCE225H

XTCE250L, XTCS250L

XTCE300L, XTCS300L

XTCE400M, XTCS400M, XTCE500M,
XTCS500M, XTCE570M, XTCS570M

XTCE185H–XTCEC20R

0.8 x Ucmin–1.15 x Ucmax

0.7 x Ucmin–1.15 x Ucmax

0.7 x Ucmin–1.15 x Ucmax

0.7 x Ucmin–1.15 x Ucmax

XTCS250L–XTCS500M

—

0.85 x Ucmin–1.1 x Ucmax

0.85 x Ucmin–1.1 x Ucmax

0.85 x Ucmin–1.1 x Ucmax

Description
Voltage Tolerance
Pickup (x Uc)

Dropout (x Uc)
XTCE185H–XTCEC20R

0.2 x Ucmin–0.6 x Ucmax

0.2 x Ucmin–0.6 x Ucmax

0.2 x Ucmin–0.6 x Ucmax

0.2 x Ucmin–0.6 x Ucmax

XTCS250L–XTCS500M

—

0.2 x Ucmin–0.4 x Ucmax

0.2 x Ucmin–0.4 x Ucmax

0.2 x Ucmin–0.4 x Ucmax

Power Consumption of the Coil at Cold State and 1.0 x Uc
XTCE185H–XTCEC20R
Pickup VA

210 1

250 1

380 1

450 1

Pickup W

180

200

250

350

Sealing VA

2.6

4.3

4.3

4.3

Sealing W

2.1

3.3

3.3

3.3

XTCS250L–XTCS500M
Pickup VA

—

360

360

715

Pickup W

—

325

625

645

Sealing VA

—

4.3

4.3

4.3

Sealing W

—

3.3

3.3

3.3

—

100

100

100

Duty factor (%DF)

Switching Time at 100% Main Contact Uc (Approximate Values)
XTCE185H–XTCEC20R
Closing delay (ms)

<60

<100

<80

<80

Opening delay (ms)

<40

<80

<110

<80

XTCS250L–XTCS500M
Closing delay (ms)

—

<50

<55

<50

Opening delay (ms)

—

<40

<40

<40

Reaction in Threshold and Sealing State Transition Range (XTCE185H–XTCEC20R)
Voltage interruptions
(0–0.2 x Ucmin) <10 ms

Time is bridged successfully

Time is bridged successfully

Time is bridged successfully

Time is bridged successfully

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

(0.2–0.6 x Ucmin) <12 ms

Time is bridged successfully

Time is bridged successfully

Time is bridged successfully

Time is bridged successfully

(0.2–0.6 x Ucmin) >12 ms

Contactor remains switched on

Contactor remains switched on

Dropout of the contactor

Contactor remains switched on

(0.6–0.7 x Ucmin)

Contactor remains switched on

Contactor remains switched on

Contactor remains switched on

Contactor remains switched on

(1.15–1.3 x Ucmax)

Contactor remains switched on

Contactor remains switched on

Contactor remains switched on

Contactor remains switched on

(>1.3 x Ucmax) <3s

Contactor remains switched on

Contactor remains switched on

Contactor remains switched on

Contactor remains switched on

(>1.3 x Ucmax) >3s

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Contactor does not switch on

Contactor does not switch on

Contactor does not switch on

Contactor does not switch on

(0–0.2 x Ucmin) >10 ms
Voltage dips

Excess voltage

Pickup phase
(0–0.7 x Ucmin)
(0.7 x Ucmin –1.15 x Ucmax)

Contactor switches on with certainty

Contactor switches on with certainty

Contactor switches on with certainty

Contactor switches on with certainty

(>1.15 x Ucmax)

Contactor switches on with certainty

Contactor switches on with certainty

Contactor switches on with certainty

Contactor switches on with certainty

Note
1 Control transformer with U <6%.
k

1
1
1
1
V5-T1-90

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Coil Data—Frames H–R, continued

Description

XTCE185H, XTCE225H

XTCE250L, XTCS250L

XTCE300L, XTCS300L

XTCE400M, XTCS400M,
XTCE500M, XTCS500M,
XTCE570M, XTCS570M

Reaction in Threshold and Sealing State Transition Range (XTCE185H–XTCEC20R), continued

1
1

Permissible contact resistance (of the external command
device with actuation of A11), ohms

—

≤500

≤500

≤500

1

Permissible residual current (with actuation of A11
by the electronics with 0 signal)

—

≤1

≤1

≤1

1

High

15V

15V

15V

15V

Low

5V

5V

5V

5V

1

SPS signal level (A3–A4) to IEC/EN 61131-2 (Type 2)

Electromagnetic compatibility (EMC)

1
1

This product is designed for operation in industrial environments (environment 2). The use in residential environments
(environment 1) could cause electrical interference so that addition suppression must be planned.

1
Coil Data—Frames N–R

1

XTCE580N

XTCE750N,
XTCE820N

XTCEC10N

XTCEC14P

XTCE16R,
XTCEC20R

XTCE185L–XTCEC20R

0.7 x Ucmin–1.15 x Ucmax

0.7 x Ucmin–1.15 x Ucmax

0.7 x Ucmin–1.15 x Ucmax

0.7 x Ucmin–1.15 x Ucmax

0.7 x Ucmin–1.15 x Ucmax

XTCS185L–XTCS500M

0.85 x Ucmin–1.1 x Ucmax

0.85 x Ucmin–1.1 x Ucmax

0.85 x Ucmin–1.1 x Ucmax

0.85 x Ucmin–1.1 x Ucmax

0.85 x Ucmin–1.1 x Ucmax

XTCE185L–XTCEC20R

0.2 x Ucmin–0.6 x Ucmax

0.2 x Ucmin–0.6 x Ucmax

0.2 x Ucmin–0.6 x Ucmax

0.2 x Ucmin–0.6 x Ucmax

0.2 x Ucmin–0.6 x Ucmax

XTCS185L–XTCS500M

0.2 x Ucmin–0.4 x Ucmax

0.2 x Ucmin–0.4 x Ucmax

0.2 x Ucmin–0.4 x Ucmax

0.2 x Ucmin–0.4 x Ucmax

0.2 x Ucmin–0.4 x Ucmax

Description

1

Voltage Tolerance
Pickup (x Uc)

Dropout (x Uc)

Power Consumption of the Coil at Cold State and 1.0 x Uc
800 1

800 1

800 1

800 1

1600 1

Pickup W

700

700

700

700

1400

Sealing VA

7.5

7.5

7.5

7.5

15

Sealing W

6.5

6.5

6.5

6.5

13

—

—

—

—

—

Pickup W

—

—

—

—

—

Sealing VA

—

—

—

—

—

Sealing W

—

—

—

—

—

100

100

100

100

100

Duty factor (%DF)

1
1
1
1

XTCS185L–XTCS500M
Pickup VA

1

1

XTCE185L–XTCEC20R
Pickup VA

1

1
1
1
1

Switching Time at 100% Main Contact Uc (Approximate Values)

1

XTCE185L–XTCEC20R
Closing delay (ms)

<70

<70

<70

<70

<70

Opening delay (ms)

<70

<70

<70

<40

<40

1

Closing delay (ms)

—

—

—

—

—

1

Opening delay (ms)

—

—

—

—

—

XTCS185L–XTCS500M

1

Note
1 Control transformer with U <7%.
k

1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-91

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Coil Data—Frames N–R, continued
Description

XTCE580N

XTCE750N,
XTCE820N

XTCEC10N

XTCEC14P

XTCE16R,
XTCEC20R

Reaction in Threshold and Sealing State Transition Range (XTCE185L–XTCEC20R)
Voltage interruptions
(0–0.2 x Ucmin) <10 ms

Time is bridged
successfully

Time is bridged
successfully

Time is bridged
successfully

Time is bridged
successfully

Time is bridged
successfully

(0–0.2 x Ucmin) >10 ms

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Time is bridged
successfully

Time is bridged
successfully

Time is bridged
successfully

Time is bridged
successfully

Time is bridged
successfully

(0.2–0.6 x Ucmin) >12 ms

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

(0.6–0.7 x Ucmin)

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

(1.15–1.3 x Ucmax)

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

(>1.3 x Ucmax) <3s

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

Contactor remains
switched on

(>1.3 x Ucmax) >3s

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

Dropout of the contactor

(0–0.7 x Ucmin)

Contactor does not
switch on

Contactor does not
switch on

Contactor does not
switch on

Contactor does not
switch on

Contactor does not
switch on

(0.7 x Ucmin –1.15 x Ucmax)

Contactor switches on
with certainty

Contactor switches on
with certainty

Contactor switches on
with certainty

Contactor switches on
with certainty

Contactor switches on
with certainty

(>1.15 x Ucmax)

Contactor switches on
with certainty

Contactor switches on
with certainty

Contactor switches on
with certainty

Contactor switches on
with certainty

Contactor switches on
with certainty

Permissible contact resistance (of the external
command device with actuation of A11), ohms

<500

<500

<500

<500

<500

Permissible residual current (with actuation of A11
by the electronics with 0 signal)

<1

<1

<1

<1

<1

High

15V

15V

15V

15V

15V

Low

5V

5V

5V

5V

5V

1

1

1

1

1

Voltage dips
(0.2–0.6 x Ucmin) <12 ms

Excess voltage

Pickup phase

SPS signal level (A3–A4) to IEC/EN 61131-2 (Type 2)

Electromagnetic compatibility (EMC)

Note
1 This product is designed for operation in industrial environments. Usage in domestic areas can cause radio frequency interference (RFI).
Noise suppression measures must be provided for the additional interference.

1
1
1
1
1
1
1
1
1
1
V5-T1-92

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

XT Contactors—Four-Pole
Description

XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

IEC/EN 60947,
VDE 0660, UL,
CSA

IEC/EN 60947,
VDE 0660, UL,
CSA

IEC/EN 60947,
VDE 0660, UL,
CSA

IEC/EN 60947,
VDE 0660, UL,
CSA

IEC/EN 60947,
VDE 0660, UL,
CSA

IEC/EN 60947,
VDE 0660, UL,
CSA

IEC/EN 60947,
VDE 0660, UL,
CSA

IEC/EN 60947,
VDE 0660, UL,
CSA

AC operated

0.22 [0.49]

0.49 [1.1]

0.49 [1.1]

1.0 [2.3]

1.0 [2.3]

2.8 [6.2]

2.8 [6.2]

2.8 [6.2]

DC operated

0.29 [0.64]

0.49 [1.1]

0.49 [1.1]

1.0 [2.3]

1.0 [2.3]

2.8 [6.2]

2.8 [6.2]

2.8 [6.2]

10,000,000

10,000,000

10,000,000

10,000,000

10,000,000

10,000,000

10,000,000

10,000,000

AC operated

5000

5000

5000

5000

5000

3600

3600

3600

DC operated

5000

5000

5000

5000

5000

3600

3600

3600

See Curves,
Page
V5-T1-111

See Curves,
Page
V5-T1-111

See Curves,
Page
V5-T1-111

See Curves,
Page
V5-T1-111

See Curves,
Page
V5-T1-111

See Curves,
Page
V5-T1-111

See Curves,
Page
V5-T1-111

See Curves,
Page
V5-T1-111

General
Standards

Weights in kg [lb]

Mechanical life—operations
Mechanical operating frequency (ops/hr)

Electrical life

Electrical operating frequency (ops/hr)

600

600

600

600

600

600

600

600

Climatic proofing

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

Insulation voltage (Ui) Vac

690

690

690

690

690

690

690

690

Impulse withstand voltage (Uimp) Vac

8000

8000

8000

8000

8000

8000

8000

8000

Operation voltage (Ue) Vac

690

690

690

690

690

690

690

690

400

440

440

440

440

440

440

440

Between contacts (Vac)
Making capacity up to 690V (amps)

400

440

440

440

440

440

440

440

144

238

350

560

700

1120

1330

1800

120

180

250

00

00

800

950

1150

380/400V

120

180

250

400

500

800

950

1150

500V

100

180

250

400

500

800

950

1150

660/690V

70

120

144

250

296

650

750

800

1
1
1
1

1
1
1
1
1
1
1

Type 2 coordination

1

400V; gG/gL 500V

20

35

35

63

80

160

160

250

690V; gG/gL 690V

2

35

35

50

63

160

160

200

400V; gG/gL 500V

35

6

100

125

160

250

250

250

690V; gG/gL 690V

25

50

50

80

80

200

200

200

IP20

IP00

IP00

IP00

IP00

IP00

IP00

IP00

—

—

—

IP20

IP20

IP20

IP20

IP20

Finger and
back-of-hand
proof

Finger and
back-of-hand
proof

Finger and
back-of-hand
proof

Finger and
back-of-hand
proof

Finger and
back-of-hand
proof

Finger and
back-of-hand
proof

Finger and
back-of-hand
proof

Finger and
back-of-hand
proof

1

Type 1 coordination

Protection against direct contact when
actuated from front (IEC 536)

1

1

Short-circuit protection rating maximum fuse

Degree of protection with accessories

1

1

Breaking capacity (amps)
220/230V

1

1

Safe isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and contacts (Vac)

1

1
1

Notes
1 Damp heat, constant, to IEC 60068-2-3.
2 Damp heat, cyclical, to IEC 60068-2-30.

1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-93

1
1

IEC Contactors and Starters
XT IEC Power Control

XT Contactors—Four-Pole, continued
Description

XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

General, continued
Terminal capacity main cable—screw terminals

1

Solid (mm2)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–16)
2 x (0.75 –10)

1 x (0.75–16)
2 x (0.75 –10)

1 x (2.5 –16)
2 x (2.5 –16)

1 x (2.5 –16)
2 x (2.5 –16)

—

—

—

1

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–16)
2 x (0.75–10)

1 x (0.75–16)
2 x (0.75–10)

1 x (2.5–35)
2 x (2.5–25)

1 x (2.5–35)
2 x (2.5–25)

1 x (10 –95)
2 x (10–70)

1 x (10 –95)
2 x (10–70)

1 x (10 –95)
2 x (10–70)

Solid or stranded (AWG)

18–14

18–6

18–6

12–2

12–2

8–250 kcmil

8–250 kcmil

8–250 kcmil

Solid (mm2)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

1 x (0.75–4)
2 x (0.75–2.5)

Flexible with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

1 x (0.75–2.5)
2 x (0.75–2.5)

Solid or stranded (AWG)

18–14

18–14

18–14

18–14

18–14

18–14

18–14

18–14

1
1
1
1
1
1
1
1
1
1
1

Terminal capacity control circuit cable—screw
terminals

Main cable connection screw/bolt
Tightening torque
Nm

1.2

3

3

3.3

3.3

14

14

14

Lb-in

10.6

26.6

26.6

29.2

29.2

123.9

123.9

123.9

Nm

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

Lb-in

10.6

10.6

10.6

10.6

10.6

10.6

10.6

10.6

Control circuit cable connection screw/bolt
Tightening torque

Tools
Main and control circuit cable—
Screw terminals

2

2

2

2

2

—

—

—

Pozidriv screwdriver

0.8 x 5.5

0.8 x 5.5

0.8 x 5.5

0.8 x 5.5

0.8 x 5.5

—

—

—

Standard screwdriver

1x6

1x6

1x6

1x6

1x6

—

—

—

Mounting position, AC and DC operated

30°

°

1

1

Open

–25 to 60°C
(–13 to 140°F)

–25 to 60°C
(–13 to 140°F)

–25 to 60°C
(–13 to 140°F)

–25 to 60°C
(–13 to 140°F)

–25 to 60°C
(–13 to 140°F)

–25 to 60°C
(–13 to 140°F)

–25 to 60°C
(–13 to 140°F)

–25 to 60°C
(–13 to 140°F)

1

Enclosed

–25 to 40°C
(–13 to 104°F)

–25 to 40°C
(–13 to 104°F)

–25 to 40°C
(–13 to 104°F)

–25 to 40°C
(–13 to 104°F)

–25 to 40°C
(–13 to 104°F)

–25 to 40°C
(–13 to 104°F)

–25 to 40°C
(–13 to 104°F)

–25 to 40°C
(–13 to 104°F)

–40 to 80°C
(–40 to 176°F)

–40 to 80°C
(–40 to 176°F)

–40 to 80°C
(–40 to 176°F)

–40 to 80°C
(–40 to 176°F)

–40 to 80°C
(–40 to 176°F)

–40 to 80°C
(–40 to 176°F)

–40 to 80°C
(–40 to 176°F)

–40 to 80°C
(–40 to 176°F)

90

90

°

1

90
°

1

180°

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

1
1

1

Ambient temperature

Ambient storage temperature

1
1
1
1
1
1
1
V5-T1-94

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

XT Contactors—Four-Pole, continued
Description

XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

1
1

Environmental
Mechanical shock resistance (IEC/EN 60068-2-27)

1

Half-sinusoidal shock 10 ms
Main contact—NO contact

10g

10g

10g

10g

10g

10g

10g

10g

Auxiliary contact—NO contact

7g

7g

7g

7g

7g

7g

7g

7g

Auxiliary contact—NC contact

5g

5g

5g

5g

5g

5g

5g

5g

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

III/3

III/3

III/3

III/3

1
1
1

Coil Data Voltage Tolerance
Pickup (x Uc)

1

AC operated

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

0.8–1.1

DC operated

0.8–1.1

0.7–1.2

0.7–1.2

0.7–1.2

0.7–1.2

0.7–1.2

0.7–1.2

0.7–1.2

1
1

Dropout (x Uc)
AC operated

0.4–0.6

0.4–0.6

0.4–0.6

0.4–0.6

0.4–0.6

0.4–0.6

0.4–0.6

0.4–0.6

DC operated

0.2–0.6

0.2–0.6

0.2–0.6

0.2–0.6

0.2–0.6

0.2–0.6

0.2–0.6

0.2–0.6

1

Power Consumption of the Coil at Cold State and 1.0 x Uc
AC operated 50/50Hz

1

Pickup VA

24

50

50

150

150

180

180

180

Pickup W

19

40

40

95

95

150

150

150

Sealing VA

4

8

8

16

16

3.1

3.1

3.1

Sealing W

1.2

2.4

2.4

4

4

2.1

2.1

2.1

1

Pickup W

4.5

12

12

24

24

149

149

149

1

Sealing W

4.5

0.5

0.5

0.5

0.5

2.1

2.1

2.1

100

100

100

100

100

100

100

100

1

DC operated

Duty factor (%DF)

1

Switching Time at 100% Uc (Approximate Values)

1

Main contact
AC operated

1

Closing delay (ms)

15 to 21

6 to 22

6 to 22

12 to 18

12 to 18

28 to 33

28 to 33

28 to 33

Opening delay (ms)

9 to 18

8 to 14

8 to 14

8 to 13

8 to 13

35 to 41

35 to 41

35 to 41

1

31

47

47

54

54

35

35

35

1

DC operated
Closing delay (ms)
Opening delay (ms)
Arcing time (ms)

12

30

30

24

24

30

30

30

10

10

10

10

10

15

15

15

1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-95

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Auxiliary Contacts

XTCE007B_–
XTCE032C

XTCEXFAC_
XTCEXFATC_

XTCEXFCC_
XTCEXSCC_

XTCEXFAG_

XTCEXSBLN_
XTCEXSBN_
XTCEXSBNC_
XTCEXSCN_
XTCEXSCNC_

Interlocked opposing contacts with an auxiliary contact
module (to IEC 60947-5 -1 Annex L)

—

Yes

Yes

Yes

Yes

Break contact (not late-break contact) suitable as a mirror
contact (to IEC/EN 60947-4 -1 Annex F)

XTCE007B_–
XTCE032C

XTCE007B_–XTCE032C

XTCE007B_–XTCE032C

XTCE040D_–XTCE065D_ XTCE040D_–XTCE065D_
XTCE185L_–XTCEC10N_

Rated impulse withstand voltage, (Uimp) Vac

6000

6000

6000

6000

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

III/3

Rated insulation voltage, (Ui) Vac

690

690

690

690

690

Rated operational voltage, (Ue) Vac

500

500

500

500

500

Between coil and auxiliary contacts

400

400

400

440

440

Between the auxiliary contacts

400

400

400

440

440

230V

6A

6A

6A

6A

6A

380/415V

4A

3A

4A

4A

4A

500V

1.5A

—

1.5A

1.5A

1.5A

1
1
1
1
1
1
1
1
1
1
1

Description

6000

Safe isolation to VDE 0106 Part 101 and Part 101(A) in Vac

Rated operational current, le
AC-15

DC-3 L/R <5 ms 1

1

24V

10A

10A

10A

10A

10A

60V

6A

6A

6A

6A

6A

1

110V

3A

3A

3A

3A

3A

220V

1A

1A

1A

1A

1A

1

Conventional thermal current, Ith

16A

16A

16A 3

10A

10A

1

Control circuit reliability
(at Ue = 24 Vdc, Umin = 17 V, Imin = 5.4 mA)

<10-8, <1 failure at
100 million operations

<10-8, <1 failure at
100 million operations

<10-8, <1 failure at
100 million operations

<10-8, <1 failure at
100 million operations

<10-8, <1 failure at
100 million operations

Component lifespan, operations x 106
at Ue = 230V, AC-15, 3A

1.3

1.3

1.3

1.3

1.3

10A

10A

10A

16A

16A

1
1
1
1

Short-circuit rating without welding 2
Maximum fuse, gG/gL

Notes
1 Making and breaking conditions to DC-13, time L/R contact as stated.
2 See fuses overlay for time/current characteristic (on request).
3 Conventional thermal current (I ) of XTCEXSCC_ is 10A.
th

1
1
1
1
1
1
1
1
1
1
V5-T1-96

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Parallel Link
Description

1

XTCEXPLKB

XTECXPLKC

XTCEXPLKD

XTCEXPLKG

XTCEXPLK185

Solid (mm2)

1–16

16

16

—

—

Flexible with ferrule (mm2)

1 x (0.5–25)
2 x (0.5–16)

1 x (16–35)

1 x (16–120)

—

—

1

Stranded (mm2)

1 x (0.5–25)
2 x (0.5–16)

1 x (16–50)

1 x (16–120)

1 x (35–300)
2 x (35–120)

—

1

Flat conductor—number of segments x width x thickness (mm)

6 x 9 x 0.8

—

—

2 x (11 x 21 x 1)

1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)

4

4

14

—

—

Pozidriv screwdriver

Size 2

Size 2

—

—

—

Hexagon socket head spanner—SW (mm)

—

—

5

6

—

1

Three-pole (Ith) A

50

100

180

400

—

1

Four-pole (Ith) A

60

—

—

—

—

1

Terminal capacity

Tightening torque (Nm)

1
1

Tools

Conventional thermal current

1
1

Cable Terminal Block, Flat Cable Terminal
Description

1

XTCEXTLA400

XTCEXPLK185

XTCEXTFB650

XTCEXTFB820

Stranded (mm2)

1 x (120–300)
2 x (70–240)

—

—

—

1

Stranded (AWG)

1 x (250–600 kcmil)
2 x (2/0–500 kcmil)

—

—

—

1

Flat conductor—number of segments x width x thickness (mm)

—

1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)

1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)

1 x (6 x 16 x 0.8)
2 x (10 x 40 x 1)
2 x (20 x 40 x 0.5)

1

1

Terminal capacity

1
1

AC Ratings—AC-1 Operation
Description

XTCE007B

XTCE009B

XTCE012B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

at 40°C (Ith)

22A

22A

22A

22A

40A

45A

45A

at 50°C (Ith)

21A

21A

21A

21A

38A

43A

43A

at 55°C (Ith)

21A

21A

21A

21A

37A

42A

42A

at 60°C (Ith)

20A

20A

20A

20A

35A

40A

40A

Enclosed

18A

18A

18A

18A

32A

36A

36A

Open

50A

50A

50A

50A

88A

100A

100A

Enclosed

45A

45A

45A

45A

80A

90A

90A

Conventional free air thermal current, three-pole, 50–60 Hz

1
1

Open

1
1
1

Conventional free air thermal current, single-pole (Ith)

1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-97

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC-3 Operation
XTCE007B

XTCE009B

XTCE012B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

220/230V

7

9

12

15.5

18

25

32

240V

7

9

12

15.5

18

25

32

380/400V

7

9

12

15.5

18

25

32

415V

7

9

12

15.5

18

25

32

1

440V

7

9

12

15.5

18

25

32

500V

5

7

10

12.5

18

25

32

1

660/690V

4

5

7

9

12

15

18

1000V

—

—

—

—

—

—

—

1
1
1

1

Description
Rated operational current, 50/60 Hz

1 (I

e) in amperes

Rated power (P) in kilowatts

1

220/230V

2.2

2.5

3.5

4

5

7.5

10

240V

2.2

3

4

4.6

5.5

8.5

11

1

380/400V

3

4

5.5

7.5

7.5

11

15

415V

4

5.5

7

8

10

14.5

19

440V

4.5

5.5

7.5

8.4

10.5

15.5

20

500V

3.5

4.5

7

7.5

12

17.5

23

660/690V

3.5

4.5

6.5

7

11

14

17

1000V

—

—

—

—

—

—

—

XTCE007B

XTCE009B

XTCE012B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

220/230V

5

6

7

7

10

13

15

240V

5

6

7

7

10

13

15

380/400V

5

6

7

7

10

13

15

1

415V

5

6

7

7

10

13

15

440V

5

6

7

7

10

13

15

1

500V

4.5

5

6

6

1

13

1

660/690V

4

4.5

5

5

8

10

12

1

1000V

—

—

—

—

—

—

—

1
1
1
1
1
1
1

1
1
1
1
1
1
1
1

AC Ratings—AC-4 Operation
Description
Rated operational current, 50/60 Hz 2 (Ie) in amperes

Rated power (P) in kilowatts
220/230V

1

1.5

2

2

2.5

3.5

4

240V

1.5

1.6

2.2

2.2

3

4

4.5

380/400V

2.2

2.5

3

3

4.5

6

7

415V

2.3

2.8

3.4

3.4

5

6.5

7.5

440V

2.4

3

3.6

3.6

5.5

7

8

500V

2.5

2.8

3.5

3.5

6

8

9

660/690V

2.9

3.6

4.4

4.4

6.5

8.5

10

1000V

—

—

—

—

—

—

—

Notes
1 At maximum permissible ambient temperature.
2 Example—
The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an
AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.

1
1
1
V5-T1-98

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC-6A Operation
Description

XTCE007B

XTCE009B

XTCE012B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

1

Transformer loads

Values are
application specific

Values are
application specific

Values are
application specific

Values are
application specific

Values are
application specific

Values are
application specific

Values are
application specific

1

Calculation is Ie AC-3 = X / 6 * Ie transformer where X is the inrush current of the transformer and Ie transformer is the nominal current. 1

1
1

AC Ratings—AC-6B Operation
Description

XTCE007B

XTCE009B

XTCE012B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

Capacitor loads
Individual compensation rated operational current Ie
of three-phase capacitors in amperes

1
1

Up to 525V

See Page V5-T1-63 for capacitor ratings

690V

See Page V5-T1-63 for capacitor ratings

1

Maximum inrush current peak (x Ie)

30

30

30

30

30

30

30

Component lifesaving (operations)

—

—

—

—

—

—

—

Maximum operating frequency (ops/hr)

—

—

—

—

—

—

—

1
1
1

AC Ratings—AC-1 Operation
Description

XTCE040D

XTCE050D

XTCE065D

XTCE072D

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE170G

1

Conventional free air thermal current,
three-pole, 50–60 Hz
Open
at 40°C (Ith)

60A

80A

98A

98A

110A

130A

160A

190A

275A 2

at 50°C (Ith)

57A

71A

88A

88A

98A

125A

142A

180A

200A

at 55°C (Ith)

55A

68A

83A

83A

94A

115A

135A

170A

190A

at 60°C (Ith)

50A

65A

80A

80A

90A

110A

130A

160A

185A

45A

58A

72A

72A

80A

100A

115A

144A

166A

Open

125A

162A

200A

200A

225A

275A

325A

400A

460A

Enclosed

112A

145A

180A

180A

200A

250A

285A

360A

415A

Enclosed

1

Conventional free air thermal current,
single-pole (Ith)

Notes
1 Example—
The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an
AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.
2 For 225–275A, use 2X 70 mm2 wire.
3 At maximum permissible ambient temperature.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-99

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC-3 Operation
Description

XTCE040D

Rated operational current, 50/60 Hz

1 (I

XTCE050D

XTCE065D

XTCE072D

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE170G

e) in amperes

220/230V

40

50

65

72

80

95

115

150

170

240V

40

50

65

72

80

95

115

150

170

380/400V

40

50

65

7

80

95

115

150

170

415V

40

50

65

72

80

95

115

150

170

1

440V

40

50

65

72

80

95

115

15

170

500V

40

50

65

72

80

95

115

150

170

1

660/690

25

32

37

37

65

80

93

100

150

1000V

—

—

—

—

—

—

—

—

—

1

1

Rated power (P) in kilowatts

1

220/230V

12.5

15.5

20

22

25

30

37

48

52

240V

13.5

17

22

35

27.5

34

40

52

57

1

380/400V

18.5

22

30

37

37

45

55

75

90

415V

24

30

39

41

43

57

70

91

100

440V

25

32

41

44

51

60

75

95

105

500V

28

36

47

45

58

70

85

110

120

660/690V

23

30

35

35

63

75

90

96

140

1000V

—

—

—

—

—

—

—

—

—

XTCE040D

XTCE050D

XTCE065D

XTCE072D

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE170G

220/230V

18

21

25

25

40

50

55

65

65

240V

18

21

25

25

40

50

55

65

65

380/400V

18

21

25

25

40

50

55

65

65

1

415V

18

21

25

25

40

50

55

65

65

440V

18

21

25

25

40

50

55

65

65

1

500V

18

21

25

25

40

50

55

65

65

660/690V

14

17

20

20

40

50

45

50

50

1

1000V

—

—

—

—

—

—

—

—

—

20

1
1
1
1
1
1
1

1

AC Ratings—AC-4 Operation
Description
Rated operational current, 50/60 Hz 1 (Ie) in amperes

Rated power (P) in kilowatts
220/230V

5

6

7

7

12

16

17

20

1

240V

5.5

6.5

7.5

7.5

13

17

19

22

22

380/400V

9

10

12

12

20

26

28

33

33

1

415V

9.5

11

13

13

24

30

33

39

39

440V

10

12

14

14

25

32

35

41

41

500V

11

13

16

16

29

36

40

47

47

660/690V

12

14

17

17

26

35

43

48

48

1000V

—

—

—

—

—

—

—

—

—

1
1
1

Note
1 At maximum permissible ambient temperature.

1
1
1
1
1
V5-T1-100

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC6-A Operation
Description

XTCE040D

XTCE050D

XTCE065D

XTCE072D

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE170G

Transformer loads

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Calculation is Ie AC-3 = X / 6 * Ie transformer where X is the inrush current of the transformer and Ie transformer is the nominal current. 1

1
1
1
1

AC Ratings—AC6-B Operation
Description

XTCE040D

XTCE050D

XTCE065D

XTCE072D

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE170G

1

Capacitor loads
Individual compensation rated operational current Ie of
three-phase capacitors in amperes
Up to 525V

See Page V5-T1-63 for capacitor ratings

690V

See Page V5-T1-63 for capacitor ratings

Maximum inrush current peak (x Ie)

30

30

30

30

30

30

1
30

30

30

Component lifesaving (operations)

—

—

—

—

—

—

—

—

—

Maximum operating frequency (ops/hr)

—

—

—

—

—

—

—

—

—

XTCE185H

XTCE225L

XTCE250L

XTCE300L

XTCE400M

XTCE500M

XTCE570M

XTCE580N

Conventional free air thermal current, three-pole, 50–60 Hz
at 40°C (Ith)

337

356

429

490

612

857

857

980

at 50°C (Ith)

301

310

383

438

548

767

767

876

at 55°C (Ith)

287

295

366

418

522

731

731

836

at 60°C (Ith)

275

285

350

400

500

700

700

800

245

275

875

315

1250

1750

1750

2000

Conventional free air thermal current, single-pole (Ith)

1
1
1
1

AC Ratings—AC-1 Operation
Description

1

1
1
1

Note
1 Example—The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an
AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-101

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC-3 Operation
XTCE185H

XTCE225L

XTCE250L

XTCE300L

XTCE400M

XTCE500M

XTCE570M

XTCE580N

220/230V

185

225

250

300

400

500

580

580

240V

185

225

250

300

400

500

580

580

380/400V

185

225

250

300

400

500

580

580

415V

185

225

250

300

400

500

580

580

1

440V

185

225

250

300

400

500

580

580

500V

185

225

250

300

400

500

580

580

1

660/690V

150

160

250

210

400

500

580

580

1000V

76

76

76

95

95

95

95

435

220/230V

55

70

75

90

125

155

185

185

240V

62

75

85

100

132

170

200

200

380/400V

90

110

132

160

200

250

315

315

415V

110

132

148

180

240

300

348

348

1

440V

115

138

157

185

255

345

370

370

500V

132

160

180

215

290

360

420

420

1

660/690V

140

150

240

195

344

344

344

560

1000V

108

108

108

132

132

132

132

600

XTCE185H

XTCE225L

XTCE250L

XTCE300L

XTCE400M

XTCE500M

XTCE570M

XTCE580N

1
1
1

1
1
1

1
1
1

Description
Rated operational current, 50/60 Hz

1 (I

e) in amperes

Rated power (P) in kilowatts

AC Ratings—AC-4 Operation
Description
Rated operational current, 50/60 Hz 1 (Ie) in amperes

1

220/230V

136

164

200

200

296

360

360

456

240V

136

164

200

200

296

360

360

456

1

380/400V

136

164

200

200

296

360

360

456

415V

136

164

200

200

296

360

360

456

1

440V

136

164

200

200

296

360

360

456

500V

136

164

200

200

296

360

360

456

660/690V

110

120

200

200

296

360

360

456

1000V

55

55

76

76

95

95

95

348

1
1

Rated power (P) in kilowatts

1

220/230V

41

51

62

75

92

112

112

143

240V

45

54

68

82

101

122

122

156

1

380/400V

75

90

110

132

160

200

200

250

415V

80

96

117

142

176

216

216

274

440V

85

102

125

150

186

229

229

290

1

500V

96

116

143

172

214

260

260

330

660/690V

102

110

189

160

283

344

344

440

1

1000V

77

77

108

109

132

132

132

509

1

1

Note
1 At maximum permissible ambient temperature.

1
1
1
1
1
V5-T1-102

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC-1 Operation
Description

XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC16R

XTCEC20R

1

Conventional free air thermal current, three-pole,
50–60 Hz
at 40°C (Ith)

1041

1102

1225

1225

1714 1

2200

2450 1

at 50°C (Ith)

931

986

1095

1095

1533 1

1970

2190 1

at 55°C (Ith)

888

940

1044

1044

1462 1

1800

2089 1

at 60°C (Ith)

850

900

1000

1000

1400 1

1800

2000 1

2125

2250

2500

2500

3500

4500

5000

Conventional free air thermal current,
single-pole (Ith)

1
1
1
1
1

AC Ratings—AC-3 Operation
Description

XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC16R

XTCEC20R

220/230V

650

750

820

1000

—

1600

—

240V

650

750

820

1000

—

1600

—

1
1

Rated operational current, 50/60 Hz 2 (Ie) in amperes

1
1

380/400V

650

750

820

1000

—

1600

—

415V

650

750

820

1000

—

1600

—

440V

650

750

820

1000

—

1600

—

500V

650

750

820

1000

—

1600

—

660/690V

650

750

820

1000

—

1600

—

1000V

435

580

580

700

—

—

—

1

220/230V

205

240

260

315

—

500

—

240V

225

260

285

340

—

550

—

1

1
1

Rated power (P) in kilowatts

380/400V

355

400

450

560

—

900

—

415V

390

455

500

610

—

930

—

440V

420

480

525

650

—

1000

—

500V

470

550

600

730

—

1180

—

660/690V

630

720

750

1000

—

1600

—

1000V

600

800

800

1000

—

—

—

1
1
1
1

Notes
1 Up to 690V.
2 At maximum permissible ambient temperature.

1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-103

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC-4 Operation
XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC16R

XTCEC20R

220/230V

512

576

656

800

—

1280

—

240V

512

576

656

800

—

1280

—

380/400V

512

576

656

800

—

1280

—

415V

512

576

656

800

—

1280

—

1

440V

512

576

656

800

—

1280

—

500V

512

576

656

800

—

1280

—

1

660/690V

512

576

656

800

—

1280

—

1000V

348

464

464

700

—

—

—

—

1
1
1

1

Description
Rated operational current, 50/60 Hz

1 (I

e) in amperes

Rated power (P) in kilowatts

1

220/230V

161

181

209

260

—

30

240V

176

200

228

280

—

450

—

1

380/400V

280

315

355

450

—

750

—

415V

307

346

394

490

—

770

—

440V

32

367

41

520

—

830

—

500V

370

417

474

590

—

940

—

1
1
1
1
1

660/690V

494

556

633

780

—

1300

—

1000V

509

678

678

1000

—

—

—

AC Ratings—AC-6A Operation
Description
Transformer loads

1
1
1
1

XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC16R

XTCEC20R

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Values are
application
specific

Calculation is Ie AC-3 = X / 6 * Ie transformer where X is the inrush current of the transformer and Ie transformer is the nominal current. 2
Notes
1 At maximum permissible ambient temperature.
2 Example—The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an
AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.

1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-104

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

AC Ratings—AC-6B Operation
Description

XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC16R

XTCEC20R

1

Capacitor loads
Individual compensation rated operational
current Ie of three-phase capacitors in amperes
Up to 525V

463

463

463

463

—

—

—

690V

265

265

265

265

—

—

—

30

30

30

30

—

—

—

Maximum inrush current peak (x Ie)
Component lifesaving (operations)

100,000

100,000

100,000

100,000

—

—

—

Maximum operating frequency (ops/hr)

200

200

200

200

—

—

—

1
1
1
1
1

AC Ratings—Four-Pole—AC-1 Operation
Description

1

XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

at 40°C (Ith)

22

32

45

3

80

125

160

200

at 50°C (Ith)

21

30

41

60

76

116

15

188

at 60°C (Ith)

20

28

39

54

69

108

138

172

Enclosed (amps)

18

27

36

50

64

100

128

160

1

Open (amps)

60

84

117

162

207

325

415

516

1

Enclosed (amps)

54

76

105

146

186

292

373

464

Conventional free air thermal current, three-pole, 50-60 Hz
Open (amps)

1
1
1

Conventional free air thermal current, single-pole

1
1

AC Ratings—Four-Pole—AC-3 Operation
XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

1

220/230V

12

18

25

40

50

80

95

115

1

240V

12

18

25

40

50

80

95

115

380/400V

12

18

25

40

50

80

95

115

415V

12

18

25

40

50

80

95

115

440V

12

18

25

40

50

80

95

115

500V

10

18

25

40

50

80

95

115

660/690V

7

12

15

25

32

65

80

93

220/230V

3.5

5

7.5

2.5

15.5

25

30

37

240V

4

5.5

8.5

13.5

17

27.5

33

40

380/400V

5.5

7.5

11

18.5

22

37

45

55

415V

7

10

14.5

24

30

48

57

70

Description
Rated operational current, 50/60 Hz (Ie) in amperes

1
1
1
1

Rated power, (P) in kilowatts

440V

7.5

10.5

15.5

25

32

51

60

75

500V

47

12

17.5

28

36

58

70

85

660/690V

6.5

11

14

23

30

63

75

90

1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-105

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1

Description
Rated Operation
Current {1} (Ie) in
Amperes

XTCE007B

XTCE009B

XTCE012B,
XTCF020B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

XTCE040D

XTCE050D

XTCE065D
72

60V

20

20

20

20

35

40

40

50

60

110V

20

20

20

20

35

40

40

50

50

72

220V

15

15

15

15

3

4

40

45

45

65

440V

1

1.3

1.3

1.3

2.9

2.9

2.9

2.9

2.9

2.9

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE185H

XTCE225H

XTCE250L

XTCE300L

XTCE400M

XTCE500M

60V

110

110

160

160

300

300

300

300

400

400

110V

110

110

16

160

300

300

300

300

400

400

220V

70

70

90

90

300

300

300

300

400

400

440V

4.5

4.5

4.5

4.5

11

11

11

11

11

11

XTCE580N

XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC20R

XTCEC16R

60V

—

—

—

—

—

—

—

—

110V

—

—

—

—

—

—

—

—

220V

—

—

—

—

—

—

—

—

440V

—

—

—

—

—

—

—

—

XTCE009B

XTCE012B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

XTCE040D

XTCE050D

XTCE065D
72

DC Ratings—DC-3
Description
Rated Operation
Current {1} (Ie) in
Amperes

XTCE007B

60V

20

20

20

20

35

35

40

50

60

110V

20

20

20

20

35

35

40

50

50

72

220V

1.5

1.5

1.5

1.5

10

10

25

25

25

35

440V

0.2

0.2

0.2

0.2

0.6

0.6

0.6

0.6

0.6

0.6

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE185H

XTCE225H

XTCE250L

XTCE300L

XTCE400M

XTCE500M

1
1

XT IEC Power Control

DC Ratings—DC-1

1
1

IEC Contactors and Starters

60V

110

110

160

160

300

300

300

300

400

400

1

110V

110

110

160

160

300

300

300

300

400

400

220V

35

35

40

40

300

300

300

300

400

400

1

440V

1

1

1

1

—

—

—

—

—

—

XTCE580N

XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC20R

XTCEC16R

1
1
1

60V

—

—

—

—

—

—

—

—

110V

—

—

—

—

—

—

—

—

220V

—

—

—

—

—

—

—

—

440V

—

—

—

—

—

—

—

—

1
1
1
1
1
1
V5-T1-106

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

DC Ratings—DC-5

1

Description
Rated Operation
Current {1} (Ie) in
Amperes

XTCE007B

XTCE009B

XTCE012B

XTCE015B

XTCE018C

XTCE025C

XTCE032C

XTCE040D

XTCE050D

XTCE065D

60V

20

20

20

20

35

35

40

50

60

72

110V

20

20

20

20

35

35

40

50

50

72

220V

1.5

1.5

1.5

1.5

10

10

25

25

25

35

440V

0.2

0.2

0.2

0.2

0.6

0.6

0.6

0.6

0.6

0.6

1

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE185H

XTCE225H

XTCE250L

XTCE300L

XTCE400M

XTCE500M

60V

110

110

160

160

300

300

300

300

400

400

1

110V

110

110

160

160

300

300

300

300

400

400

220V

35

35

40

40

300

300

300

300

400

400

440V

1

1

1

1

—

—

—

—

—

—

XTCE580N

XTCE650N

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC20R

60V

—

—

—

—

—

—

—

110V

—

—

—

—

—

—

—

220V

—

—

—

—

—

—

—

440V

—

—

—

—

—

—

—

1
1
1

1
1
1
1
1
1
1

DC Ratings—Four-Pole—DC-1 Operation

1

Description
Rated Operation
Current {1} (Ie) in
Amperes

XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

60V

22

32

45

63

80

125

160

200

110V

22

32

45

6

80

125

160

200

220V

6

32

45

63

80

125

160

200

440V

1.3

3

3

5

5

100

125

150

1
1
1
1

DC Ratings—Four-Pole—DC-3 Operation

1

Description
Rated Operation
Current {1} (Ie) in
Amperes

XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

60V

20

32

45

63

80

125

160

200

110V

20

32

45

63

80

125

160

200

220V

1.5

32

45

63

80

125

160

200

440V

0.2

6

6

8

8

75

95

115

1
1
1
1
1

DC Ratings—Four-Pole—DC-5 Operation

1

Description
Rated Operation
Current {1} (Ie) in
Amperes

XTCF020B

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

XTCF160G

XTCF200G

60V

20

32

45

63

80

125

160

200

110V

20

25

32

508

80

125

160

200

220V

1.5

15

22

38

70

100

125

150

440V

0.2

4

4

8

8

60

75

90

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-107

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Current Heat Loss (Three-Pole) in Watts
Description

XTCE007B

1
1
1
1
1

1
1
1
1
1

XTCE015B

XTCE018C

XTCE025C

XTCE032C

XTCE040D

at Ith

3

3

3

3

7.3

9.6

12.1

11.3

at Ie to AC-3/400V

0.37

0.6

1.1

1.8

1.9

3.8

6.1

7.2

2.5

2.5

2.5

2.5

2

2

2

1.5

XTCE050D

XTCE065D

XTCE072D

XTCE080F

XTCE095F

XTCE115G

XTCE150G

XTCE170G

at Ith

19

28.8

28.8

12.2

18.2

20.3

30.7

41.1

at Ie to AC-3/400V

11.3

19

23

9.6

13.5

15.9

27.0

34.7

1.5

1.5

1.5

0.5

0.5

0.4

0.4

0.4

XTCE185H

XTCE225H

XTCE250L

XTCE300L

XTCE400M

XTCE500M

XTCE580N

XTCE650N

at Ith

34

45

55

37

58

113

61

69

at Ie to AC-3/400V

16

23

28

21

37

58

32

41

—

—

—

—

—

—

—

—

XTCE750N

XTCE820N

XTCEC10N

XTCEC14P

XTCEC20R

XTCEC16R

XTCF160G

XTCF200G

Impedance per pole, megohms

Current heat loss (three-pole) in watts

Impedance per pole, megohms

Current heat loss (three-pole) in watts

Impedance per pole, megohms

1
1

XTCE012B,
XTCF020B

Current heat loss (three-pole) in watts

1
1

XTCE009B

Current heat loss (three-pole) in watts
at Ith

78

96

96

188

192

155

at Ie to AC-3/400V

54

65

96

—

—

123

—

—

—

—

—

—

XTCF032C

XTCF045C

XTCF063D

XTCF080D

XTCF125G

Impedance per pole, megohms

Current Heat Loss (Four-Pole) in Watts
Description

XTCF020B

Current heat loss (four-pole) in watts
at Ith
Impedance per pole, megohms

4.7

8.2

12

16

23

29

46

60

2.5

2

1.5

1

0.7

0.6

0.6

0.5

1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-108

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Wiring Diagrams

1

7–150A XTCR Reversing Contactors
Control Circuit—7–32A

Control Circuit—40–170A

21
22

0

0
II

1
1

21
22

22
21
22
21
14
13
I
14
13
14
14
K2M
K1M
13
13
22
K2M
K1M 22
21
21
A1
A1
K1M
K2M
A2
A2
(-)N

22
21
21
22
13
14
I
14
13
54
54
K1M
K2M 53
53
22
22
K2M 21
K1M 21
A1
A1
K1M
K2M
A2
A2
II

Power Circuit—7–150A with
Mechanical Interlock 80–
150A on Mounting Plate

1 3 5
K1M

1

13 5

1

2 4 6 K2M 2 4 6

M1

1

UV W
M
3

1
1

Star-Delta (Wye-Delta) Starters

XTCC Contactors for Three-Phase Capacitors

Power Circuit—12–385A AC-3

Power Circuit—11–85 kVar

L1 L2 L3

1
1

L1 L2 L3

1

F1
B 1 x ln
135
2 4 6 K5M

K1M

0.58 x ln

135
2 4 6 K3M

A
0.58 x ln

13 5
246

C

21
0 22
S11
K1M
13
14

54 54 54
K1M 53 53 53
K3M K5M
A1
K1M
(–)N

A2

K1T

N

17
K1 18 K1

17
28

22
22
K5M 21 K3M 21
A1
A1
A1
K5M
K3M
A2
A2
A2
Y

Control Circuit—70–1700A AC-3
21
0 22
S11
I

13
14

K1M
13
14

44 14 14
K1M 43 13 13
K3M K5M
A1
K1M
(–)N

A2
N

K1T

1

A2

2 4 6

1

C1

1

R11

1

R11

Control Circuit—12–55A AC-3

13
14

1 3 5

1

U1
V2
V1 M1 W2
W1 3~ U2
M1

I

A1

17
K1 18 K1

17
28

R11

In the case of group
compensation, multi-stage
capacitor banks are
connected to the mains, as
required. In the process,
transient currents of up to
180 x Ie can flow between
the capacitors. The capacitors
are pre-charged via the earlymake auxiliary contacts and
the fitted wire resistors,
thereby reducing the inrush
current. The main contacts
then close after a time lag
and carry the uninterrupted
current. The contactors for
capacitors are weld-resistant
with inrush current peaks up
to 180 x 1 Ie due to their
special contacts. For
switching reactive-power
compensation equipment
with chokes, observe
design notes.

For switching of power factor
connection with reactors,
please observe engineering
notes, Page V5-T1-64. Use of
the contactors XTCE without
series resistor for centralized
power factor correction—
when using contactors for
group compensation, a
minimum inductance of
approximately 6 μH per
capacitor must be available to
limit the high inrush current
peaks. This corresponds to an
air-cored coil with 5 windings
and a coil diameter of
approximately 140 mm
diameter. The conductor
cross-section must be
selected according to the
rated current per phase.

1
1
1
1
1
1
1
1
1
1
1
1

22
22
K5M 21 K3M 21

1

A1
A1
A1
K3M
K5M
A2
A2
A2

1

Y

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-109

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Contactor Contact Travel Diagrams
Frame B
XTCE 7–15A, XTC—AC

XTCE 7–9A—DC

NO contact

NO contact

NC contact

1

XTCEXSAC11

1

NO contact

1

NC contact

0

3.3

0

4.5
4.5

1.0

NC contact

XTCE 12–15A, XTCF—DC

0
0

NO contact

2.1 2.9

NC contact

2.9

0.7

XTCEXSAC11
0
0

3.2

4.5
4.5

1.6

NO contact
NC contact

0
0

3.3

4.4
4.4

1.0

XTCEXSAC11
0
0

NO contact

2.3 2.9

NC contact

2.9

0.7

0
0

3.2

4.4
4.4

1.6

1
1
1
1
1
1
1

XTCEXF...LC_
NO contact
NC contact

XTCEXF...LC_
0

2.0

0

2.8

4.5

0

1.1

NO contact

2.9

NC contact

2.9

1.9

0
0

Frame D

Frames F and G

XTCE 40–72A

XTCE 80–170A

NO contact

0

Auxiliary NC

4

6.0

NO contact

XTCEXF...G_

NC contact
XTCEXSAC11, XTCEXF...C_

NC contact

0

3.2

XTCEXF...LC_
0

2.0

11

0

0

9.2 11

0

NO contact

5.7 7.5

NC contact

7.5

3.9

7.4

11

0

7.3

11

XTCEXF...LG_
0
0

NO contact

7.5

3.8

NC contact

5.4 7.5

XTCEXS...N_
0

0

2.8

0

8.9 11

0

8.95 11

6

XTCEXS...N_

6

NO contact

1

8

6

1.6

NC contact

1

0

XTCEXF...G_

XTCEXF...LG_
0

NO contact

NC contact

4.4

2.8

6

1
NO contact

NO contact

5.1 7.5

4.4

3.2

NO contact

1

0

2.0

1.8

Auxiliary NO

NO contact

1

NC contact

0

XTCE 15–32A

1

1

NO contact

Frame C

1
1

4.5

XTCEXF...LC_

NC contact

0
0

NO contact

5.45 7.5
3.6

NC contact

7.5

0

7.1

11

1
XTCEXSBLN11

1

NO contact

1

NC contact

1
1

XTCEXSBLN11
0
0

4.1

NO contact

7.5

NC contact

4.95 7.5

Note: The diagrams indicate the closing and travel of the contacts of the contactors and auxiliary
contacts at no-load. Tolerances are not taken into consideration.

1
1
V5-T1-110

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

0
0

7.6

11

8.45 11

XT IEC Power Control

Electrical Life Curves

1

Normal Switching Duty

170
150
115
95
80
65
50
40
32

7.5
5.5
4
3

kW

AC-3/400V
XTCE170G
XTCE150G
XTCE115G
XTCE095F

XTCE080F

XTCE065D
XTCE050D
XTCE040D
XTCE032C

25

XTCE025C

18

XTCE015B

XTCE018C

12

XTCE012B

9
7

XTCE009B, XTMC9A
XTCE007B

5
4

XTMC9A

3

XTMC9A
2

0.01

0.02

0.04 0.06 0.1

0.2

0.4 0.6

1

2

4

6

10

Component Lifespan (millions of operations)

900

A
1600 XTCEC16R

560

1000 XTCEC10N

450
400
355
315
250
200
160
132
110
90
75
55
45
37
30

Rated Operational Current Ie 50 – 60 Hz

A

90
75
55
45
37
30
22
18.5
15
11

1

XTCE185H–XTCEC16R

Rated Output of Three-phase Motors 50 – 60 Hz

kW
Rated Operational Current Ie 50 – 60 Hz

Rated Output of Three-phase Motors 50 – 60 Hz

XTCE007B–XTCE170G

820
750

AC-3/400 V

1

650 XTCE650N
580 XTCE580N

1

500 XTCE500M
400 XTCE400M
300 XTCE300L
250
225

XTCE250L
XTCE225H

185

XTCE185H

1
1

145
104

1

85
72

1

58

22

43

18.5

36

15

30

11
7.5

23
16

1
1
0.04 0.06 0.1

0.2

0.4 0.6

1

2

3 4 5 6 8 10

Component Lifespan (millions of operations)

1

5.5
4
3.5
2.5

AC-4/400V

A

100
90
80
66

XTCE150G,
XTCE170G
XTCE115G
XTCE095F
XTCE080F

40 XTCE065D
XTCE050D
35
32 XTCE040D
20 XTCE032C
XTCE025C
17
13

XTCE012B,
9 XTCE015B
XTCE009B
8.3
6.5 XTCE007B
5
4
3

XTMC9A

2

0.01

0.02

0.04 0.06

0.1

0.2

0.4 0.6

1

2

4

6

Component Lifespan (millions of operations)

10

A

750

1280

XTCEC16R

450
355

800
656

XTCEC10N
XTCE820N

576
512
456
360
296

XTCE750N
XTCE650N
XTCE580N
XTCE500M
XTCE400M

240
200
164
140

XTCE300L
XTCE250L
XTCE225H
XTCE185H

315
280
250
200
160
132
110
90
75
55
45
37
30
22
18.5
15
11
7.5

1
AC-4/400 V

kW

Rated Operational Current I e 50 – 60 Hz

9
7. 5

XTCE185H–XTCEC16R

Rated Output of Three-phase Motors 50 – 60 Hz

19
17
15

Rated Operational Current I e 50 – 60 Hz

XTCE007B–XTCE170G

52
47
41
33

1
1

Extreme Switching Duty

kW

1
1

XTCE820N
XTCE750N

0.01 0.02

Rated Output of Three-phase Motors 50 – 60 Hz

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1
1
1
1

104
85
72
58

1

43
36
30

1

23

1

16

5.5

12

4

8.8

3

6.5

2.2

5

1.5

3.5

1

1
0.01 0.02 0.03 0.04 0.06 0.1

0.2 0.3 0.4 0.6

1

2

3 4 5 6 8 10

1
1

Component Lifespan (millions of operations)

1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-111

1
1
1

XT IEC Power Control

Three-Pole—XTCE007B–XTCEC20R
2000
1800

XTCEC20R
XTCEC16R

1400

XTCEC14P
XTCE820N, XTCEC10N
XTCE650N XTCE750N
XTCE580N
XTCE500M

1000
900 850
800
700

1
1
1

Four-Pole—XTCF020B–XTCF200G
AC-1/400 V

AC-1/400 V

XTCE400M
XTCE300L
XTCE250L
XTCE225H
XTCE185H

200

XTCF200G

500
400
350
300
275

160

XTCF160G

125

XTCF125G

80

XTCF080D

63

XTCF063D

45

XTCF045C

160

XTCE150G, XTCE170G

130
110
90
80
65

XTCE115G
XTCE095F
XTCE080F
XTCE065D
XTCE050D

50
40
35

XTCE040D
XTCE025C, XTCE032C
XTCE018C

20

XTMC9A

Breaking Current A

1

IEC Contactors and Starters

Switching Duty for Non-Motor Loads

Breaking Current A

1

XTC

E00

1

10

1

5
4

7B,

XTC

E00

9B,

XTC

E01
2B,

7

XTC

E01
5B

32

XTCF032C

22

XTCF020B

3

1

2
0.1

0.2

1

0.4

0.6

1

2

4

6

10

Component Lifespan (millions of operations)

1
0.1

0.2

0.5

0.3

0.7

1

2

3

5

7

10

Component Lifespan (millions of operations)

1
1
1

Operating characteristics:
Non-inductive and slightly inductive loads
Electrical characteristics:
Switch on: 1 x Rated current
Switch off: 1 x Rated current
Utilization category:
100% AC-1
Typical applications:
Electrical heating

1
Short-Time Loading
Three-Pole—XTCE007B–XTCEC20R

1
1
1

600

XTCE065D

500
450
400
350

XTCE050D
XTCE040D

300

XTCE025C

1
1

150

1
1

XTCE032C

A

XTCE018C

AC-1/400 V

19000 XTCEC16R

10000 XTCE820N
XTCE750N
8000 XTCE650N
XTCE580N
6000
XTCE500M
5000
4000

200

XTCEC10N, XTCEC14P
XTC

EC2

0R

XTCE400M
XTCE300L

120

3000 XTCE250L
XTCE012B,
XTCE015B

2500

70

2000 XTCE185H, XTCE225H
1800 XTCE115G,
1500 XTCE150G,
XTCE170G

50

1100 XTCE080F, XTCE095F
1000

100

1

AC-1/400 V

A
700

250

1

Three-Pole—XTCE080F–XTCEC16R
Short-time Current

1

Short-time Current

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

90

XTCE007B,
XTCE009B

40

700
30

500
400

20
15

300

1
2

1

3

5

7

10

20

30

Duration of load

50 70 100
1 min

200 300
3 min 5 min

500 700 900 Seconds

200

10 min 15 min

2

3

5

7

10

20

30

Duration of load

1
1
V5-T1-112

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

50 70 100

200 300

1 min 3 min 5 min

500 700 900
10 min 15 min

Seconds

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Maximum Operating Frequency—Related to Rating and Utilization Category (400V)
7 to 150 hp

185 to 820 hp

Ops./h

Ops./h

6000

1
1

4000

4000

a

3000

b

2000

c

1500

a
b
c

1

d

1

d
2000

1

1000
800
600

e
1000

500

800

400

f

300

600

1

e

1

200
400

1

g

150

1

100
200

1

50
0

10

20

30

40

50

60

70

80

90

100
0

10

20

30

50

40

60

70

80

90

100 %

PN [kW/hp]

100 %

1

PN [kW/hp]

1
Utilization Category 1

Utilization Category 1

1

Characteristic Curve Above

Characteristic Curve Above
Type

AC-1

AC-3

AC-2, AC-4

Type

AC-1

AC-3

AC-2, AC-4

XTCE007B–XTCE015B

3

1

5

XTCE185H

2

1

6

XTCE018C–XTCE032C

3

2

5

XTCE225H

2

1

6

XTCE040D–XTCE065D

3

2

5

XTCE250L

2

1

6

XTCE080F–XTCE150G

3

4

5

XTCE300L

3

2

7

XTCE400M

3

2

7

XTCE500M

3

2

7

XTCE580N

3

4

5

XTCE650N

3

4

5

XTCE750N

3

4

5

XTCE820N

3

4

5

1
1
1
1
1
1
1

Note
1 P = max. motor rating (kW/hp) of the relevant contactor.
N
ops./h = max. number of operations per hour.

1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-113

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Dimensions
Approximate Dimensions in mm [in]

1

XTCE Contactors (Three-Pole)

1

Frame B, XTCE007B and XTCE015B Contactors with Screw Terminals (7–15A) XTCF020B

1

36 [1.42]

1

4 x M4 Dia.

1

68
[2.68]

18
[.71]

1

60 [2.36]

45
[1.77]

1
1
1

8.7 [.34]
Typ.

3.2 [.13]
6.5 [.26]

5.1 [.20]

75 [2.95]

45 [1.77]

1
1

C

Auxiliary
Type

C

XTCEXFAC_

117 [4.61]

XTCEXFCC_

117 [4.61]

35 [1.38]

XTCEXFATC_ 125 [4.92]

Frame B, XTCEC007B–XTCEC012B Contactors with Spring Cage Terminals (7–12A)

1
1
1

26.4
[1.04]

1

68
[2.68]

4 x M4 Dia.

52.3
[2.06]

60 [2.36]

1
1

1.8
[.07]
1.8
[.07]

1
1

8.7 [.34]
Typ.

3.2 [.13]
6.5 [.26]

35 [1.38]

75 [2.95]
5.1 [.20]

125.2 [4.93]

45 [1.77]

1
1
1
1
1
1
1
1
1
1
V5-T1-114

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

Frame C, XTCE018C–XTCE032C Contactors (18–32A)

1
1

38
[1.50]

1

71
[2.80]

60.4
[2.38]

2 x M4 Dia.

85
[3.46]

1
1

75 [2.95]

1
1

4.5 [.17]

4.8 [.19]
17.7 [.70]

6.4
[.25]

11.6
[.46]

4.5 [.17]

1

6.5 [.26]

10.6
[.42]

97.4 [3.83]

35 [1.38]

138.7 [5.46]

11.6
[.46]
45 [1.77]

1
1

Note: Sideways distance to grounded parts: 6 mm [.39 in]

1
Frame D, XTCE040D–XTCE072D Contactors (72A)

1
1
4 x M4 Dia.

1
1

104
[4.09]
57
[2.24]
86.4
[3.40]

1

105 [4.13]

1
1
1

34.4 [1.35]
55 [2.17]

1

45 [1.77]

4.7 [.19]

1

6.9 [.27]
113.8 [4.48]
132.1 [5.20]
146.8 [5.78]

1

Note: Sideways distance to
grounded parts: 6 mm [.39 in]

1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-115

1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Frames F–G, XTCE080F–XTCE170G Contactors (80–170A)

1
4 x M6 Dia.

1
156 [6.14]

1

156 [6.14]

1

170 [6.69]

1
57 [2.24]
76.5 [3.01]

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

1
1
1
1
90 [3.54]

1
1
1

70 [2.79]

82.5 [3.25]
85.5 [3.37]
142 [5.59]

111 [4.37]

Note: Sideways distance to
grounded parts: 10 mm [.39 in]

160 [6.30]

Frames H–M, XTCE185H–XTCE570M Contactors (185–580A)

1

W1
W
11 [.43] Dia.

1

M6 Dia.

1
1
1

H2

H3

H1 H

1
1

W3

1

1

D2
8 [.31]

D

1
1

W2

D1

W4

W

W1

W2

W3

W4

H

H1

H2

H3

D

D1

D2

Frame H

140 [5.51]

160 [6.30]

120 [4.72]

20 [.79]

41 [1.61]

180 [7.09]

165 [6.50]

190 [7.48]

160 [6.30]

158 [6.22]

4 [.16]

83 [3.27]

Frame L

140 [5.51]

160 [6.30]

120 [4.72]

20 [.79]

48 [1.89]

180 [7.09]

164 [6.46]

189 [7.44]

160 [6.30]

208 [8.19]

5 [.20]

140 [5.51]

Frame M

160 [6.30]

180 [7.09]

130 [5.12]

25 [.98]

48 [1.89]

200 [7.87]

184 [7.24]

209 [8.23]

180 [7.09]

216 [8.50]

6 [.24]

140 [5.51]

160 [6.30]

180 [7.09]

130 [5.12]

38 [1.50]

57 [2.24]

200 [7.87]

189 [7.44]

219 [8.62]

180 [7.09]

216 [8.50]

6 [.24]

140 [5.51]

1
1
1
1
1
V5-T1-116

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

Frame N, XTCE580N–XTCEC10N Contactors (580–1000A)

1

A Dia.

1

M6
Dia.

1
1

232
[9.13]

215
[8.46]

256 H
[10.08]

1
1
1

165 [6.50]

1
80
[3.15]
250 [9.84]

D1

1

232 [9.13]

1

W
140 [5.51]

270 [10.63]
W

H

D1

A (Dia.)

XTCE580N

45 [1.77]

296 [11.65]

6 [.24]

13.5 [.53]

XTCE650N

45 [1.77]

296 [11.65]

6 [.24]

13.5 [.53]

XTCE750N

45 [1.77]

296 [11.65]

6 [.24]

13.5 [.53]

XTCE820N

45 [1.77]

296 [11.65]

6 [.24]

13.5 [.53]

XTCEC10N

45 [1.77]

296 [11.65]

10 [.40]

13.5 [.53]

1
1
1
1
1

Frame P, XTCEC14P Contactor (1400A, AC-1)

1
M6 Dia.

1
1

210
342
[8.27]
[13.46]
232
256
[9.13]
[10.08]

1

215
[8.46]

1

308
[12.13]

1
165 [6.50]
60
[2.36]
100
[3.94]

14 [.55]
Dia.
100
[3.94]

130 [5.12]

1

10
[.39]

1

232 [9.13]

1

260 [10.24]

1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-117

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Frame R, XTCEC16R, XTCEC20R Contactors

1
1
1

210
[8.27]

392
[15.43]
300
272
[11.81]
10.71]
352
[13.86]

1
1
1
1

150 [5.91]

1

80 [3.15]

40
[1.57]
80 [3.15]

150 [5.90]

125 [4.92]

14 [.55]
Dia.

1
1

172.5 [6.79]

252 [9.92]

172.5 [6.79]

515 [20.28]

1
1

M6 Dia.

1
1

270
[10.63]

1
1
1

430 [16.93]

1
1
1
1
1
1
1
1
1
1
1
V5-T1-118

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

10 [.39]

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

XTCF Contactors (Four-Pole)

1

Frame B, XTCF020B Contactors

1
45.0
18.0 [1.77]
[0.71]

1

2 x M4

60.0
[2.36]

1

68.0
[2.68]

36.0
[1.42]

1
3.2
[0.13]

45.0
[1.77]

1

6.5
[0.26]
35.0
[1.38]

75.0
[2.95]

1

117.0
[4.61]

1
1

Frame C, XTCF032C–XTCF045C Contactors

1
85.0
[3.35]

1

2 x M4

60.0
38.0 [2.36]
[1.50]
71.0
[2.80]

1

75.0
[2.95]

1
1

58.0
[2.28]

4.5
[0.18]

6.5
[0.26]

35.0
[1.38]

1

97.4
[3.83]

1

138.0
[5.43]

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-119

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Frame D, XTCF063D–XTCF080D Contactors

1
1
57.0
[2.24]

1

2 x M4

115.0
[4.53]

86.4
[3.40]

105.0
[4.13]

104.0
[4.09]

1
1
1
1

74.0
[2.91]

4.7
[0.19]

85.0
[3.35]

6.9
[0.27]
114.0
[4.49]

45.0
[1.77]
132.1
[5.20]
147.0
[5.79]

1
1

Frame G, XTCF125G–XTCF200G Contactors

1
1

4 x M6

170.0
[6.69]

1
57.0
[2.24]

1

156.0
[6.14]

156.0
[6.14]

1
1
1

122.0
[4.80]

1

82.5
[3.25]
85.5
[3.37]

133.0
[5.24]

1

70.0
[2.76]
142.0
[5.59]

1

175.0
[6.89]

1

160.0
[6.30]

1
1
1
1
1
1
1
1
V5-T1-120

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

XTAE Starters with XTOB Overload Relay
Frame B, XTAE007B–XTAE015B Starters with
XTOB (7–12A)
45.3
[1.78]
35
[1.38]

Mounting
Holes for
M4 or #8
Screws
(4 Places)

117.1
[4.61]

60
[2.36]
45
[1.77]

75.8
[2.98]

1

Frame D, XTAE040D–XTAE065D Starters with XTOB
(40–65A)
Mounting
Holes for
M4 or #8
Screws
(4 Places)

1

146
[5.75]

1

132.5
[5.22]

1
1

60
[2.36]

1

105
[4.13]

117.8
[4.64]

1

174
[6.85]

1
1

83.3 [3.28]
88.4 [3.48]
To Reset

1
1

Frame C, XTAE018C–XTAE032C Starters with
XTOB (18–32A)
45
[1.77]
35
[1.38]

Mounting
Holes for
M4 or #8
Screws
(2 Places)

98 [3.86]
To Reset
93.6 [3.69]

1
1

139.8
[5.50]
97.8
[3.85]

1
1
1

75
[2.95]

1

136.4
[5.37]

1
1
1
100.2 [3.94]
105.3 [4.15]
To Reset

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-121

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Frames F–G, XTAE080F–XTAE150G Starters with XTOB (80–150A)
90 [3.54]
70 [2.76]

1

160 [6.30]
150 [5.91]

1
1
1
1

170
57
[2.24] [6.69]

156
[6.14]

1
1
1

277
[10.91]

1
1
91
[3.58]

1

74
[2.91]

1
1
1
1

7 [.276]
Dia.

95 [3.74]
100 [3.94]
118 [4.65]

134 [5.28]

1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-122

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

XTAE Starters with C396 Overload Relay
Frame B, XTAE007B–XTAE012B Starters
with XTOE (0.35–20A)
117.0 [4.61]

Mounting
Holes for
M4 or #8
Screws
(4 places)

75.8 [2.98]

143.2
[5.64]

60.0
[2.36]
100.6
[3.96]

10.6 [0.42]
Reset

110.4 [4.35]

140.0 [5.50]
98.0 [3.80]

222.3
[8.75]
To Reset

75.0
[2.95]
117.3
[4.62]

132.4 [5.21]
To Reset
140.2 [5.52]

156.0
[6.14]

10.6 [0.42]
Reset

1
1

Terminal
Torque:
14 Nm
[124 lb-in]
21.3 [0.84]

1

1

77.0
[3.00]
18.2 [0.71] Trip/Test
10.6 [0.42] Reset
36.0 [1.42]

89.0
[3.50]

1
1

152.0
[6.00]

146.1 [5.75]

1
1

345.0
[13.6]

5.0
[0.20]

1
1

Frame G, XTAE115G–XTAE150G Starters
with XTOE (100–175A)
M6 [#10] Screws

45.0 [1.77] Mtg.
55.0 [2.17]

213.6
[8.41]

1

56.0 [2.20]

Frame D, XTAE040D–XTAE065D Starters
with XTOE (20–100A)

105.0
[4.13]
Mtg.

1

41.2 [1.62] Mtg.

Mtg. Holes
for (2) M4
or #8 Screws

18.2 [0.71]
Trip/Test

Mtg. Holes for
(4) #8 Screws or
M4 Screws

1
1

70.0
[2.76]

5.0 [0.20]

1

156.0
[6.14]
Mtg. 167.3
[6.59]
Mtg.

2.5–3.0 Nm
[22–26 lb-in]

5.0 [0.20]

175.0 [6.89]
160.0 [6.30]

108.4
[4.27]
Mtg.
45.0 [1.77]
35.0 [1.38]

Mounting
Holes for
M4 or #8
Screws
(2 places)

102.7 [4.04]
110.4 [4.35]

1

Mtg. Holes for
(4) M6 or #10
Screws

70.0
[2.76]

7.8
[0.31]

291.1
[11.46]

Frame C, XTAE018C–XTAE032C Starters
with XTOE (0.35–45A)

161.0
[6.30]

1

90.0
[3.54]
Mtg.

1
18.2 [0.71]
Trip/Test

102.7 [4.04]

1

111.8
[4.40]

45.3 [1.78]
35.0 [1.38]

1.2 Nm
[11 lb-in]

1

Frames F–G, XTAE080F–XTAE115G Starters
with XTOE (20–100A)

1

157.0 [6.18]
161.0 [6.30]

1

110.0 [4.30]

1
1

159.7
[6.29]
To Reset

1
1
1

38.7 [1.52]
To Reset

1

136.2 [5.36]
To Reset

Volume 5—Motor Control and Protection

1
CA08100006E—August 2012

www.eaton.com

V5-T1-123

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
XTCR Reversing Combination
Frames B–D

1
1
1

H

1
1
1
1
1
1

W

D

Frame B (7–15A)

Frame C (18–32A)

Frame D (40–65A)

W

H

D

W

H

D

W

H

D

90
[3.54]

68
[2.68]

117
[4.61]

90
[3.54]

85
[3.34]

138
[5.43]

110
[4.33]

115
[4.53]

146.8
[5.78]

Frames F–G

1
1
1
1
1
1
1

299
314
[11.77] [12.36]

1
1
1
1
1
1
176 [6.93]

1

M6

196 [7.72]

183 [7.20]

1
1
1
1
1
V5-T1-124

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Approximate Dimensions in mm [in]

1

Star-Delta Combination

1

Frames B–D

1
1
H

1

W
Frame B

1

D
Frame C

1

Frame D

W

H

D

W

H

D

W

H

D

158
[6.22]

68
[2.68]

117
[4.61]

158
[6.22]

85
[3.34]

138
[5.43]

188
[7.40]

115
[4.53]

146.8
[5.78]

1
1
1

Frames F–G

1
1
1
1
1
1
1

299
314
[11.77] [12.36]

1
1
1
1
1
1

144 [5.67]

144 [5.67]

1

M6

183 [7.20]

308 [12.13]

1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-125

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Mechanical Interlock
Frames H–M—XTCEXMLM

1

XTCEXMLN

15
[.59]

20
[.79]

515 [20.28]
430 [16.93]

1
1

270
[10.63]

1

300
[11.81]

1
1

9 [.35]

1
1
1
1
1

Contactor with Terminal Shroud
Frames L–N Contactors, XTCE250L–XTCEC10N,
with Terminal Shroud XTLEXTS
W

1
1
1
1

H

1
1
1
1
1

XTCE500M, XTCE570M

XTCE580N, XTCE650N,
XTCE750N, XTCE820N,
XTCEC10N

W

H

W

H

W

H

W

H

1

150
[5.91]

384
[15.12]

150
[5.91]

404
[15.91]

174
[6.85]

426
[16.77]

236
[9.29]

506
[19.92]

XTCE250L

XTCE400M

1
1
1
1
1
1
1
V5-T1-126

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

Approximate Dimensions in mm [in]
Suppressor

Flat Strip Conductor Terminals

XTCE_ Suppressor

XTCEXTFB

1
1
1

H3

H2

1
1
H1

1

H

1

D

W2

1

W1
W1

W2

H1

H2

H3

D

XTCEXRSB_
XTCEXVSB_
XTCEXVSLB_
XTCEXDSB_

25
[.98]

9.2
[.36]

25.9
[1.02]

28
[1.10]

32
[1.26]

9
[.35]

XTCEXRSC_
XTCEXVSC_
XTCEXVSLC_

25
[.98]

9.2
[.36]

16
[.63]

28
[1.10]

32
[1.26]

9
[.35]

XTCEXRSF_
XTCEXVSF_
XTCEXVSLF_

25
[.98]

20
[.79]

18.5
[.73]

28
[1.10]

32
[1.26]

9
[.35]

1
1

W

1
W

H

XTCE500M–XTCE570M

171 [6.73]

232 [9.13]

XTCE750N–XTCE820N

231 [9.09]

310 [12.20]

Cable Terminal Block

Three-Phase Commoning Link

XTCEXTLA

Frame B

1
1
1
1

18.1
[.71]

1
1

H
13.1
[.52]

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

W

12.5
[.49]

1
1

135
[5.31]

222
[8.74]

1

30
[1.18]

1

W
H

XTCEXCLK3B

112 [4.41]

XTCE250L

198 [7.80]

XTCEXCLK4B

157 [6.18]

XTCE400M

218 [8.58]

XTCBXCLK5B

202 [7.95]

1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-127

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Contents

XTOB, XTOT Overload Relays

Description

1

Page

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1

V5-T1-3
V5-T1-18
V5-T1-35
V5-T1-129
V5-T1-130
V5-T1-133
V5-T1-136
V5-T1-138
V5-T1-141
V5-T1-157
V5-T1-193
V5-T1-216
V5-T1-229

1
1
1

Thermal Overload Relays

1

Product Description

1
1
1
1

The XT line of IEC motor
thermal overload relays
provides an efficient motor
protection solution, available
up to 630A. XTOB units can
be directly mounted to the
contactor or mounted
separately.

Features and Benefits
●
●

●

●
●

●

1

●

1

●

Direct connect up to 250A
Stand alone and CT type
up to 630A
Large thermal overcurrent
range
Test button
Manual/automatic
selectable reset
NO-NC auxiliary as
standard
Class 10A (to 250A)
Class 30 (CT type)

1
1

Standards and Certifications
●
●
●
●
●
●

IEC EN 60947
CE approved
UL
CSA
ATEX
RoHS

Notes
Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct
device mounting. See MN03402001E for more information on overload relays for Frames B–G.
Trip Class: 10A
Suitable for protection of EEx e-motors. EC prototype test certificate available upon request.
See manuals MN03402001E and MN03407001E, Page V5-T1-133.

1

Instructional Leaflets
Pub51221
XTOB, D Frame overload relays
(inside of packaging)

1

Pub51222

1

XTOB, B–C Frame overload relays
(inside of packaging)

1
1
1
1
1
1
1
V5-T1-128

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Catalog Number Selection

1

XT IEC Overload Relays

1

XT OB P16 B C1 S

1

Device Type
XT = XT line of IEC control
Type
OB = Bimetallic overload relay
OT = Current transformer overload relay

Overload Release
Frame G
Frame B
035 = 25–35A
P16 = 0.1–0.16A
P24 = 0.16–0.24A
050 = 35–50A
P40 = 0.24–0.4A
070 = 50–70A
P60 = 0.4–0.6A
100 = 70–100A
001 = 0.6–1A
125 = 95–125A
1P6 = 1.0–1.6A
150 = 120–150A
2P4 = 1.6–2.4A
175 = 145–175A
004 = 2.4–4A
006 = 4–6A
Frame H
010 = 6–10A
070 = 50–70A
012 = 9–12A
100 = 70–100A
016 = 12–16A
125 = 95–125A
160 = 120–160A
Frame C
220 = 160–220A
P16 = 0.1–0.16A
250 = 200–250A
P24 = 0.16–0.24A
P40 = 0.24–0.4A
Frame L
P60 = 0.4–0.6A
070 = 50–70A
001 = 0.6–1A
100 = 70–100A
1P6 = 1.0–1.6A
125 = 95–125A
2P4 = 1.6–2.4A
160 = 120–160A
004 = 2.4–4A
220 = 160–220A
006 = 4–6A
250 = 200–250A
010 = 6–10A
300 = 200–300A
016 = 12–16A
Frame M
024 = 16–24A
063 = 42–63A
032 = 24–32A
090 = 60–90A
Frame D
125 = 85–125A
010 = 6–10A
160 = 110–160A
016 = 12–16A
240 = 160–240A
024 = 16–24A
290 = 190–290A
040 = 24–40A
400 = 170–400A
057 = 40–57A
540 = 360–540A
065 = 50–65A
075 = 65–75A
Frame N
063 = 42–63A
Frame F
090 = 60–90A
035 = 25–35A
125 = 85–125A
160 = 110–160A
050 = 35–50A
240 = 160–240A
070 = 50–70A
290 = 190–290A
100 = 70–100A
400 = 170–400A
540 = 360–540A
630 = 420–630A

Frame Size
Designation
B = 45 mm
C = 45 mm
D = 55 mm
G = 90 mm
L = 140 mm
Blank = XTOT only

C1
C3

Trip Class
= Class 10A (XTOB)
= Class 30 (XTOT)

Mounting
Blank = Direct to contactor
S
= Separate mount

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-129

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Product Selection
Frame B

Overload Relay, Direct Mount—Frame B
Short-Circuit Protection (A)

1

Overload
Releases, Ir

1

0.1–0.16

1

0.16–0.24

1

0.4–0.6

0.24–0.4

1
1
1
1
Frame C

Contact
Configuration

Fuse
Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Maximum
Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

7–15A

25

0.5

25

3

XTOBP16BC1

1NO-1NC

7–15A

25

1

25

3

XTOBP24BC1

2 4 6 98 96A2 14/ 1NO-1NC
22
1NO-1NC

7–15A

25

2

25

3

XTOBP40BC1

7–15A

25

4

25

3

XTOBP60BC1

1NO-1NC

7–15A

25

4

25

3

XTOB001BC1

97 95

0.6–1

1

1

Contact
Sequence

For Use
with
Contactor
Amp Range

1–1.6

1NO-1NC

7–15A

25

6

25

6

XTOB1P6BC1

1.6–2.4

1NO-1NC

7–15A

25

10

25

6

XTOB2P4BC1

2.4–4

1NO-1NC

7–15A

25

16

25

15

XTOB004BC1

4–6

1NO-1NC

7–15A

25

20

25

20

XTOB006BC1

6–10

1NO-1NC

7–15A

50

25

25

35

XTOB010BC1

9–12

1NO-1NC

9–15A

50

25

25

45

XTOB012BC1

12–16

1NO-1NC

12–15A

50

25

30

45

XTOB016BC1

Overload Relay, Direct Mount—Frame C

1

Short-Circuit Protection (A)

1

Overload
Releases, Ir

1

0.1–0.16

Contact
Sequence

97 95

Fuse

Contact
Configuration

For Use
with
Contactor
Amp Range

Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Maximum
Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

18–32A

25

0.5

25

3

XTOBP16CC1

1

0.16–0.24

1NO-1NC

18–32A

25

1

25

3

XTOBP24CC1

0.24–0.4

1NO-1NC

18–32A

25

2

25

3

XTOBP40CC1

1

0.4–0.6

1NO-1NC

18–32A

25

4

25

3

XTOBP60CC1

0.6–1

1NO-1NC

18–32A

25

4

25

3

XTOB001CC1

1–1.6

1NO-1NC

18–32A

25

6

25

6

XTOB1P6CC1

1

1.6–2.4

1NO-1NC

18–32A

25

10

25

6

XTOB2P4CC1

2.4–4

1NO-1NC

18–32A

25

16

25

15

XTOB004CC1

1

4–6

1NO-1NC

18–32A

25

20

25

20

XTOB006CC1

1NO-1NC

18–32A

50

25

25

25

XTOB010CC1

1

6–10
10–16

1NO-1NC

18–32A

63

35

30

25

XTOB016CC1

16–24

1NO-1NC

18–32A

100

35

30

25

XTOB024CC1

24–32

1NO-1NC

25–32A

125

63

30

25

XTOB032CC1

1

1

2 4 6 989614/
22

1
1
1
1
1
1
1
1
V5-T1-130

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

Frame D

1.1

Overload Relay, Direct Mount—Frame D

1

Short-Circuit Protection (A)

Overload
Releases, Ir
6–10

Contact
Sequence

97 95

10–16
16–24

Frames F–G

Fuse

1

Contact
Configuration

For Use
with
Contactor
Amp Range

Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Maximum
Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

40–72A

50

25

25

25

XTOB010DC1

1NO-1NC

40–72A

63

35

25

25

XTOB016DC1

1NO-1NC

40–72A

63

50

30

25

XTOB024DC1

24–40

1NO-1NC

40–72A

125

63

125

125

XTOB040DC1

40–57

1NO-1NC

50–72A

160

80

150

150

XTOB057DC1

50–65

1NO-1NC

65–72A

160

100

150

200

XTOB065DC1

65–75

1NO-1NC

72A

200

125

150

200

XTOB075DC1

2 4 6 98 96

25–35

97 95

35–50
50–70

Frames F–G

Fuse

Contact
Configuration

For Use
with
Contactor
Amp Range

Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Maximum
Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

80–170A

125

100

125

125

XTOB035GC1

1NO-1NC

80–170A

160

125

150

200

XTOB050GC1

1NO-1NC

80–170A

250

160

150

200

XTOB070GC1

1NO-1NC

80–170A

315

200

400

400

XTOB100GC1

95–125

1NO-1NC

80–170A

315

200

500

400

XTOB125GC1

120–150

1NO-1NC

80–170A

315

200

600

600

XTOB150GC1

145–175

1NO-1NC

150–170A

315

200

600

600

XTOB175GC1

Fuse

Contact
Configuration

For Use
with
Contactor
Amp Range

Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Maximum
Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

80–170A

125

100

125

125

XTOB035GC1S

35–50

1NO-1NC

80–170A

160

125

150

200

XTOB050GC1S

50–70

1NO-1NC

80–170A

250

160

150

200

XTOB070GC1S

70–100

1NO-1NC

80–170A

315

200

400

400

XTOB100GC1S

95–125

1NO-1NC

80–170A

315

250

500

400

XTOB125GC1S

120–150

1NO-1NC

80–170A

315

250

600

600

XTOB150GC1S

145–175

1NO-1NC

150–170A

315

250

600

600

XTOB175GC1S

25–35

97 95

2 4 6 98 96

1
1
1
1
1
1

Short-Circuit Protection (A)

Contact
Sequence

1

1

Overload Relay, Separate Mount—Frames F–G

Overload
Releases, Ir

1

1

70–100

2 4 6 98 96

1

1

Short-Circuit Protection (A)

Contact
Sequence

1

1

Overload Relay, Direct Mount—Frames F–G

Overload
Releases, Ir

1

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-131

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame H

IEC Contactors and Starters
XT IEC Power Control

Overload Relay, Separate Mount—Frame H
Short-Circuit Protection (A)

1
Overload
Releases, Ir

1

50–70

1

Contact
Sequence

1 3 5 97 95

70–100

Contact
Configuration

For Use
with
Contactor
Amp Range

Fuse
Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Maximum
Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

185–250A

250

160

150

200

XTOB070HC1

1NO-1NC

185–250A

315

200

400

400

XTOB100HC1

1

95–125

1NO-1NC

185–250A

315

250

500

400

XTOB125HC1

120–160

1NO-1NC

185–250A

400

250

600

600

XTOB160HC1

1

160–220

1NO-1NC

185–250A

400 1

315 1

600

800

XTOB220HC1

200–250

1NO-1NC

225–250A

400 1

315 1

600

700

XTOB250HC1

2 4 6 98 96

1
1

Frame L

Overload Relay, Separate Mount—Frame L
Short-Circuit Protection (A)

1
1

Overload
Releases, Ir

1

50–70

Contact
Sequence

1 3 5 97 95

70–100

1

95–125

1
1

Fuse

Contact
Configuration

For Use
with
Contactor
Amp Range

Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Maximum
Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

185–250A

250

160

150

200

XTOB070LC1

1NO-1NC

185–250A

315

200

400

400

XTOB100LC1

1NO-1NC

185–250A

315

250

500

400

XTOB125LC1

120–160

1NO-1NC

185–250A

400

250

600

600

XTOB160LC1

160–220

1NO-1NC

185–250A

400 1

315 1

600

800

XTOB220LC1

1

315 1

600

700

XTOB250LC1

630 1

600

700

XTOB300LC1

2 4 6 98 96

200–250

1NO-1NC

225–250A

400

200–300

1NO-1NC

225–300A

630 1

1
1

Frames M-N

1

Current Transformer Operated Overload Relays, Separate Mount—Frames M–N 2

Overload
Releases, Ir

1

42–63

Contact
Sequence
97 95

Short-Circuit Protection (A)

Contact
Configuration

For Use
with
Contactor
Amp Range

Type 1
Coordination,
gG/gL

Type 2
Coordination,
gG/gL

Circuit
Breaker

CEC/NEC
Fuse

Catalog Number

1NO-1NC

300–500A

—

—

150

200

XTOT063C3S

1NO-1NC

300–500A

—

—

250

250

XTOT090C3S

1

60–90

1NO-1NC

300–500A

—

—

500

400

XTOT125C3S

1

110–160

1NO-1NC

300–500A

—

—

600

600

XTOT160C3S

160–240

1NO-1NC

300–500A

—

—

600

700

XTOT240C3S

190–290

1NO-1NC

300–500A

—

—

600

700

XTOT290C3S

1

270–400

1NO-1NC

300–500A

—

—

1000

1000

XTOT400C3S

360–540

1NO-1NC

500A

—

—

600

1000

XTOT540C3S

1

420–630

1NO-1NC

630A

—

—

600

1000

XTOT630C3S

1

Notes
1 For separate mounting, short-circuit Type 1 rating is 500A and short-circuit Type 2 rating is 400A.
2 The main current parameters are defined by the main current wiring that is used.

85–125

1

1

98 96

1
1
1
1
1
V5-T1-132

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Accessories
XTOBXDIN_

1
DIN Rail or Panel Mount Adapter,
Frames C–D 1

Terminal Lug Kit—Set of Three Lugs

For Use
with…

Pkg.
Qty. 2

Catalog Number

Description

For Use
with…

Pkg.
Qty. 2

Catalog Number

XTOB…CC1

5

XTOBXDINC

#6 AWG-350 kcmil

XTOB…LC1

1

XTOBXTLL

XTOB…DC1

2

XTOBXDIND

1
1
1
1

XTOBXTSL

XTOBXTSCL

Terminal Shroud
For Use
with…
XTOB…LC1

Documentation—Manuals for Overload Monitoring
of EEX e-motors

1

Catalog Number

Publication Number

For Use with…

XTOBXTSL

MN03402001E

XTOB…BC1
XTOB…CC1

1

MN03407001E

XTOB…DC1
XTOB…GC1

Terminal Shroud
For Direct
Mounting of …
XTOB…LC1 to XTCE250L
or XTCE300L

Catalog Number

1
1

Notes
1 Can be snap fitted on a top hat rail (DIN rail) to IEC/EN 60715 or can be screw fitted.
2 Orders must be placed in multiples of package quantity listed.

XTOBXTSCL

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-133

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Overload Fitted Directly to the Contactor
Frame B (7–15A)

Frame C (18–32A)

Frame D (40–72A)

Frames F–G (80–170A)

Frames H–L (185–250A)

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-134

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Overload Mounted Separately from the Contactor
Frame C (18–32A)

Frame D (40–72A)

Frames F–G (80–170A)

Frames H–L (185–250A)

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-135

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Technical Data and Specifications
XTOB Overload Relay—General
Description

XTOB…BC1, XTOB…CC1

XTOB…DC1

XTOB…GC1, XTOB…GC1S

XTOB…HC1, XTOB…LC1

1

Standards

IEC/EN 60947, VDE 0660,
UL, CSA

IEC/EN 60947, VDE 0660,
UL, CSA

IEC/EN 60947, VDE 0660,
UL, CSA

IEC/EN 60947, VDE 0660,
UL, CSA

1

Climate proofing

1

1

1

1

Ambient temperature

1

–25°C to 55°C
[–13°F to 131°F]

–25°C to 55°C
[–13°F to 131°F]

–25°C to 55°C
[–13°F to 131°F]

–25°C to 50°C
[–13°F to 122°F]

Temperature compensation

Continuous

Continuous

Continuous

Continuous

1

Mechanical shock resistance (IEC/EN 60068-2-27)
half-sinusoidal shock 10 ms

10g

10g

10g

10g

1

Degree of protection

IP20

IP20

IP20

P00

Protection against direct contact when actuated
from front (IEC 536)

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

1

2

Insulation voltage (Ui) Vac

690

690

690

1000

1

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

Impulse withstand voltage (Uimp) Vac

6000

6000

6000

8000

1

Operational voltage (Ue) Vac

690

690

690

1000

1
1
1
1

Safe isolation to VDE 0106 Part 101 and part 101/A1
between auxiliary contacts and main contacts (Vac)

440

440

440

500

between main contacts (Vac)

440

440

440

500

6–75A

25–150A

50–300A

<0.25

<0.25

Overload release setting range

0.1–32A

Short-circuit protection maximum fuse

See overload relay tables starting on Page V5-T1-144.

Temperature compensation residual error >40°C

<0.25

<0.25

Current heat loss (three conductors)
Lower value of setting range, W

2.5

3

16

16

Upper value of setting range

6

7.5

28

28

Solid, mm2

2 x (1–6)

2 x (1–16)

2 x (4–16)

—

1

Flexible with ferrule, mm2

2 x (1–4)
2 x (1–6) 3

1 x 25
2 x (1–10) 4

1 x (4–70)
2 x (4–50)

—
—

1

Flexible with cable lug, mm2

—

—

—

50–240

Stranded with cable lug, mm2

—

—

—

50–240

Solid or stranded, AWG

250 kcmil

1
1

1
1
1
1
1

Terminal capacity

14 - 8

14 - 2

2/0

Flat conductor (number of segments x width x thickness, mm2)

—

—

—

6 x 16 x 0.8

Busbar—width (mm)

—

—

—

25

Terminal screw

M4

M6

M10

M10 x 35

Tightening torque
Nm

1.8

3.5

10

18

Lb-in

16

31

88.5

159.31

Tools

1

Pozidriv screwdriver

Size 2

Size 2

—

—

Standard screwdriver

1x6

1x6

—

—

1

Hexagon socket head spanner (SW)

—

—

5 mm

16 mm

1
1

Notes
1 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60068-2-30.
2 Ambient temperature operating range to IEC/EN 60947, PTB: –5°C to 50°C.
3 6 mm2 flexible with ferrules to DIN 46228.
4 Main contact terminal capacity, solid and stranded conductors with ferrules: When using two conductors use identical cross-section.

1
1
1
V5-T1-136

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

XTOB Overload Relay—Auxiliary and Control Circuit Connections
Description

XTOB…BC1, XTOB…CC1

XTOB…DC1

XTOB…GC1, XTOB…GC1S

XTOB…HC1, XTOB…LC1

Impulse withstand voltage (Uimp) Vac

6000

6000

6000

4000

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

Solid, mm2

2 x (0.75–4)

2 x (0.75–4)

2 x (0.75–4)

2 x (0.75–4)

Flexible with ferrule, mm2

2 x (0.75–2.5)

2 x (0.75–2.5)

2 x (0.75–2.5)

2 x (0.75–2.5)

1
1

Terminal capacity

Solid or stranded (AWG)

1

1

2 x (18–12)

2 x (18–12)

2 x (18–12)

2 x (18–12)

M3.5

M3.5

M3.5

M3.5

Nm

0.8–1.2

0.8–1.2

0.8–1.2

0.8–1.2

Lb-in

7–10.6

7–10.6

7–10.6

7–10.6

1

Size 2

Size 2

Size 2

Size 2

1

Terminal screw

1
1

Tightening torque

Tools
Pozidriv screwdriver
Standard screwdriver
Rated insulated voltage (Ui) Vac

1x6

1x6

1x6

1x6

500

500

500

500

1
1

Rated operational voltage

500

500

500

500

Safe isolation to VDE 0106 Part 101 and part 101/A1
between auxiliary contacts

240

240

240

240

Conventional thermal current, Ith

6

6

6

6

120V

1.5

1.5

1.5

1.5

240V

1.5

1.5

1.5

1.5

415V

0.5

0.5

0.5

0.5

500V

0.5

0.5

0.5

0.5

1

120V

1.5

1.5

1.5

1.5

1

240V

1.5

1.5

1.5

1.5

415V

0.9

0.9

0.9

0.9

500V

0.8

0.8

0.8

0.8

1

24V

0.9

0.9

0.9

0.9

1

60V

0.75

0.75

0.75

0.75

1
1

Rated operational current—AC-15
Make contact

1
1

Break contact

1

Rated operational current—DC-13 L/R <15 ms 1

110V

0.4

0.4

0.4

0.4

220V

0.2

0.2

0.2

0.2

6

6

6

6

Short-circuit rating without welding maximum fuse, A gG/gl

1
1
1

Note
1 Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated.

1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-137

1

XT IEC Power Control

Tripping Characteristics
These tripping characteristics
are the mean values of the
spread at 20°C ambient
temperature in a cold state.

1
XTOB...BC1, XTOB...CC1,
XTOB...DC1

1

1
1
1
1

1
1

XTOB...HC1, XTOB...LC1

2h
100
60
40

XTOB...BC1,
XTOB...CC1,
XTOB...DC1

20
10
6
4
2
1
40
10
6
4

2-Phase

2

20
10
6
4
2

10
6
4

1.5 2

3 4

6 8 10 15 20

3-Phase

10
6
4

2-Phase

1
0.6
1

x Setting Current

10
6
4
2

2

1
0.6
1

20

20

2-Phase

2

XTOB...HC1,
XTOB...LC1

1
40

3-Phase

20

1
0.6

2h
100
60
40

XTOB...GC1

1
40

3-Phase

20

1
1

XTOB...GC1

Minutes

1

Minutes

1

2h
100
60
40

25% of the read off value.
Specific characteristics for
each individual setting
range can be found in
MN03402001E.

Seconds

1

Tripping time depends on
response current. With
devices at operating
temperature, the tripping
time of the overload relay
reduces to approximately

Minutes

1

IEC Contactors and Starters

Seconds

1

Seconds

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

1.5 2

3 4

1

6 8 10 15 20

1.5 2

3 4

6 8 10 15 20

x Setting Current

x Setting Current

Dimensions
Approximate Dimensions in mm [in]
Frames B–C, XTOB…BC1 and XTOB…CC1 Overload Relays

1
1

35.5
[1.40]

29.5
39.5 [1.16]
[1.56]

1

48
[1.89]

1
1
1
1

65 [2.56]
83 [3.27]

45 [1.77]

Frame D, XTOB…DC1 Overload Relay
51.5
[2.03]

20.3
[.80]

1
1
1
1

79.2
[3.12]

1
1
95.5 [3.76]

1

60 [2.36]

V5-T1-138

102 [4.02]

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Approximate Dimensions in mm [in]

1

Frames B–C, XTOBXDINC DIN Rail or Panel Mount Adapter
and Frame D, XTOBXDIND DIN Rail or Panel Mount Adapter

1

D1

1

42.5
[1.67]

1

H

1
1

5 [.20]

D2
16.5 [.65]

1

D

W
H

W

D

D1

D2

XTOB…CC1

85 [3.46]

45 [1.77]

90.5 [3.56]

58.3 [2.30]

3.8 [.15]

XTOB…DC1

86 [3.39]

60 [2.36]

112 [4.41]

80.5 [3.17]

4.7 [.19]

Frames F–G, XTOB…GC1 Overload Relay

1
1
1
Frames F–G, XTOB…G1CS Overload Relay

1

100 [3.94]

99 [3.90]
80 [3.15]

1

73 [2.87]

1

121
[4.76]

1

74
[2.91]
138
[5.43]

1

74
[2.91]

1
95 [3.74]
99 [3.90]
118 [4.65]
95 [3.74]
100 [3.94]
118 [4.65]

63 [2.48]
129 [5.08]
134 [5.28]

1

63 [2.48]
129 [5.08]
134 [5.28]

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-139

1
1

XT IEC Power Control

Approximate Dimensions in mm [in]
Frames L and H, XTOB…LC1, HC1 Overload Relay
121 [4.76]
110 [4.33]

1
1

IEC Contactors and Starters

144 [5.67]

96 [3.78]

111 [4.37]

48 [1.89]

1
1

144
[5.67]

**

1

*

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

74
[2.91]

7 [.28]

1

169
[6.65]

94
[3.70]

1
1
1

5*
25 [.20]
[.98]
128 [5.04]

1
1
1
1
1

7 [.28] Dia.
16.5 **
[.65]

* = OFF
** = RESET/ON

11 [.43] Dia.

XTOT…C3S Current Transformer Operated Overload Relay
185 [7.28]
4.3 [.17]

8 [.31]

21 [.83]

26
[1.02]

1
1

*

85
55
[2.17] [3.35]

71 44 [1.73] 33
[2.80]
[1.30]

1
1

185 [7.28]

1.5 [.06]

7.5 [.30]

44
[1.73]

M4
55
[2.17]

26 [1.02]
*

159 [6.26]
172 – 250
[6.77 – 9.84]
* = RESET/ON

200 [7.87]
65
[2.56]

65
[2.56]
71
[2.80]

1

90°

1

90°

90°

27
[1.06]

1
1
1
1
1
1
1
1
V5-T1-140

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Contents

C440/XT Electronic Overload Relay

Description

Page

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-3
V5-T1-18
V5-T1-35
V5-T1-128
V5-T1-142
V5-T1-143
V5-T1-144
V5-T1-146
V5-T1-149
V5-T1-155

An Eaton
Green Solution

Manual Motor Protectors . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-157
V5-T1-193
V5-T1-216
V5-T1-229

1
1
1
1
1
1
1
1
1
1

C440/XT Electronic Overload Relay
Features and Benefits

Product Description
Eaton’s new electronic
overload relay (EOL) is
the most compact, highfeatured, economical product
in its class. Designed on a
global platform, the new
EOL covers the entire power
control spectrum including
NEMA, IEC and
DP contactors. The NEMA
and DP versions are offered
with the C440 designation
while the IEC offering has the
XT designation. The
electronic design provides
reliable, accurate and value
driven protection and
communications capabilities
in a single compact device. It
is the flexible choice for any
application requiring easy-touse, reliable protection.

1

Eaton has a long history of
innovations and product
development in motor control
and protection, including both
traditional NEMA, as well as
IEC control. It was from this
experience that the C440 was
developed, delivering new
solutions to meet today’s
demands.
C440 is a self-powered
electronic overload relay
available up to 175A as a
self contained unit. With
external CTs, C440 can
protect motor up to
1500 FLA. Available add-on
accessories include remote
reset capability and
communication modules
with I/O for DeviceNet,
PROFIBUS, and Modbus.

Features
●
Reliable, accurate, electronic motor protection
●
Easy to select, install and maintain
●
Compact size
●
Flexible, intelligent design
●
Global product offering—available with NEMA, IEC and DP
power control
Size/Range
●
Broad FLA range
(0.33–1500A)
●
Selectable trip class
(10A, 10, 20, 30)
●
Direct mounting to NEMA,
IEC and DP contactors
●
Most compact electronic
overload in its class

User Interface
●
Large FLA selection dial
●
Trip status indicator
●
Operating mode LED
●
DIP switch selectable trip
class, phase unbalance and
ground fault
●
Selectable Auto/Manual
reset

Motor Control
●
Two B600 alarm (NO) and
fault (NC) contacts
●
Test/Trip button

Feature Options
●
Remote reset
●
120 Vac
●
24 Vac
●
24 Vdc

Motor Protection
●
Thermal overload
●
Phase loss
●
Selectable (ON/OFF)
phase unbalance
●
Selectable (ON/OFF)
ground fault

●
●

1
1
1
1
1
1
1
1
1
1
1
1

Tamper-proof cover
Communications modules
●
Modbus RTU RS-485
●
DeviceNet with I/O
●
PROFIBUS with I/O
●
Modbus RTU with I/O
●
Ethernet IP with I/O
●
Modbus TCP with I/O

1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-141

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Standards and Certifications

Benefits
Reliability and Improved
Uptime
●
C440 provides the users
with peace of mind
knowing that their
assets are protected
with the highest level
of motor protection and
communication capability
in its class
●
Extends the life of plant
assets with selectable
motor protection features
such as trip class, phase
unbalance and ground fault
●
Protects against
unnecessary downtime
by discovering changes
in your system (line/load)
with remote monitoring
capabilities
●
Status LED provides
added assurance that
valuable assets are
protected by indicating the
overload operational status

●

Flexibility
●
Available with NEMA,
IEC and DP contactors
●
Improves return on
investment by reducing
inventory carrying costs
with wide FLA adjustment
(5:1) and selectable
trip class
●
Design incorporates built-in
ground fault protection
thus eliminating the need
for separate CTs and
modules
●
Flexible communication
with optional I/O enables
easy integration into plant
management systems for
remote monitoring and
control
●
Available as an open
component and in
enclosed control and motor
control center assemblies

Monitoring Capabilities
●
Individual phase
currents RMS
●
Average three-phase
current RMS
●
Thermal memory
●
Fault indication (overload,
phase loss, phase
unbalance, ground fault)

●
●
●
●
●
●
●
●

UL
CSA
CE
NEMA
IEC/EN 60947 VDE 0660
ISO 13849-1 (EN954-1)
RoHS
ATEX directive 94/9/EC
Equipment Group 2,
Category 2

Safety
●
IP 20 rated terminal blocks
●
Available in Eaton’s
industry leading FlashGard
MCCs
●
Tested to the highest
industry standards such
as UL, CSA, CE and IEC
●
RoHS compliant

1
1
1
1

Electronic Overload Education
Description

Definition

Cause

Effect if not Protected

C440/XT Protection

Overload is a condition in which
current draw exceeds 115% of
the full load amperage rating for
an inductive motor.

• An increase in the load or torque that is
being driven by the motor.

• Increase in current draw leads to heat
and insulation breakdown, which can
cause system failure.

• Thermal trip behavior is defined by
UL, CSA and IEC standards.

Motor Protection
Thermal overload

1

• A poor power factor causing above
normal current draw.

1
1

• A low voltage supply to the motor
causes the current to go high to
maintain the power needed.

A line to ground fault.

A current leakage path to ground.

An undetected ground fault can burn
through multiple insulation windings,
ultimately leading to motor failure, not to
mention risk to equipment or personnel

Fixed protective setting that takes the
starter offline if ground fault current
exceeds 50% of the FLA dial setting,
i.e., if the FLA dial is set to 12A, the
overload relay will trip if the ground
current exceeds 6A.

Unbalanced phases
(voltage and current)

Uneven voltage or current between
phases in a three-phase system.

When a three-phase load is powered with
a poor quality line, the voltage per phase
may be unbalanced.

Unbalanced voltage causes large
unbalanced currents and as a result this
can lead to motor stator windings being
overloaded, causing excessive heating,
reduced motor efficiency and reduced
insulation life.

Fixed protective setting that takes the
starter offline if a phase drops below
50% of the other two phases.

Phase loss—current
(single-phasing)

One of the three-phase voltages is
not present.

Multiple causes, loose wire, improper
wiring, grounded phase, open fuse, etc.

Single-phasing can lead to unwanted
motor vibrations in addition to the results
of unbalanced phases as listed above.

Fixed protective setting that takes the
starter offline if a phase is lost.

1
1
1

• Trip class is settable from 10A,
10, 20, 30

Ground fault

1
1

• Increase in current can increase
power consumption and waste
valuable energy.

1
1
1
1
1
V5-T1-142

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Catalog Number Selection

1

XT Electronic Overload Relay—IEC 1

1

XT OE 1P6 C CS S

1
1

Mounting
Blank = Direct to contactor
P = Pass-through
S = Separate mount (Frames C and G only)

Designation
XT = XT line of IEC control
Type
OE = Electronic overload relay

1
1

Trip Type
CS = Selectable Class 10A, 10, 20, 30
GS = Ground fault with selectable Class 10, 20

1
1

Overload Range
1P6
005
020
1P6
005
020
045
045
100
100
175

=
=
=
=
=
=
=
=
=
=
=

0.33–1.65A
1–5A
4–20A
0.33–1.65A
1–5A
4–20A
9–45A
9–45A
20–100A
20–100A
35–175A

Contactor Frame
B = 45 mm

1
1

C = 45 mm

1
D = 55 mm

1

F, G = 105 mm
G, H = 110 mm

1
1

Note
1 See Page V5-T1-144 for Product Selection.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-143

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Product Selection
XT Electronic Overload Relays
45 mm XT for
Direct Mount

1

XT Electronic Overload Relays for Direct Mount to XT Contactors
For Use with
XT Contactor
Frame
B

1
1

C

1

For Use with
Contactor

Overload
Range (Amps)

XTCE007B…,
XTCE009B…,
XTCE012B…,
XTCE015B…

0.33–1.65

XTCE018C…,
XTCE025C…,
XTCE032C

Auxiliary
Contact
Configuration

45 mm

NO-NC

4–20

2 4 6 98 96

0.33–1.65

97 95

45 mm

NO-NC

1–5

2 4 6 98 96

9–45
D

1
1

F

1

XTCE040D…,
XTCE050D…,
XTCE065D…,
XTCE072D…
XTCE080F…,
XTCE095F…

9–45

97 95

20–100

45 mm

NO-NC

55 mm

Type

Catalog Number

ZEB12-1,65

XTOE1P6BCS

ZEB12-5

XTOE005BCS

ZEB12-20

XTOE020BCS

ZEB32-1,65

XTOE1P6CCS

ZEB32-5

XTOE005CCS

ZEB32-20

XTOE020CCS

ZEB32-45

XTOE045CCS

ZEB65-45

XTOE045DCS

ZEB65-100

XTOE100DCS

ZEB150-100

XTOE100GCS

2 4 6 98 96
20–100

97 95

1

55 mm

NO-NC

55 mm

NO-NC

2 4 6 98 96
G

1
1

H

1
1

97 95

Frame
Size

1–5

4–20

1

Contact
Sequence

45 mm XT for
Direct Mount
with Ground Fault

1
1

20–100

XTCE185H…

35–175

97 95

35–175

110 mm

2 4 6 98 96

110 mm

NO-NC

For Use with
XT Contactor
Frame

C

1

For Use with
Contactor

Overload
Range (Amps)

XTCE007B…,
XTCE009B…,
XTCE012B…,
XTCE015B…

0.33–1.65

XTCE018C…,
XTCE025C…,
XTCE032C

Contact
Sequence

ZEB225-175

XTOE175HCS

97 95

Auxiliary
Contact
Configuration

Type

45 mm

NO-NC

ZEB12-1,65-GF

XTOE1P6BGS

ZEB12-5-GF

XTOE005BGS

4–20

ZEB12-20-GF

XTOE020BGS

2 4 6 98 96

0.33–1.65

97 95

45 mm

NO-NC

1–5

2 4 6 98 96

9–45
D

1
F

1

XTOE100GCS
XTOE175GCS

Frame
Size

1–5

4–20

1
1

ZEB150-100
ZEB150-175

XT Electronic Overload Relays with Ground Fault for Direct Mount to XT Contactors

B

1

XTCE115G…,
XTCE150G…,
XTCE170G…

XTCE040D…,
XTCE050D…,
XTCE065D…,
XTCE072D…
XTCE080F…,
XTCE095F…

9–45

97 95

20–100

45 mm

NO-NC

55 mm

Catalog Number

ZEB32-1,65-GF

XTOE1P6CGS

ZEB32-5-GF

XTOE005CGS

ZEB32-20-GF

XTOE020CGS

ZEB32-45-GF

XTOE045CGS

ZEB65-45-GF

XTOE045DGS

ZEB65-100-GF

XTOE100DGS

ZEB150-100-GF

XTOE100GGS

2 4 6 98 96
20–100

1

97 95

55 mm

NO-NC

55 mm

NO-NC

2 4 6 98 96
G

1
1

H

XTCE115G…,
XTCE150G…,
XTCE170G…

20–100

XTCE185H…

35–175

97 95

35–175

110 mm

2 4 6 98 96

110 mm

1
1
1
V5-T1-144

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

NO-NC

ZEB150-100-GF

XTOE100GGS

ZEB150-175-GF

XTOE175GGS

ZEB225-175-GF

XTOE175HGS

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1–5A OL with CTs

45 mm XT for
Separate Mount

1.1

XT Electronic Overload Relays for use with Large Frame XT Contactors (L–R)
Use CTs and 1-5A XT overload relay. CT kit does not include overload relay (order separately).
XT
Contactor
Frame

For Use with IEC
Contactor Amp
Range (AC-3)

CT Range
(Amps)

L, M

185–500A

60-300

M, N

300–820A

N

R

1

CT Kit
Catalog Number

Terminal
Size

Overload Relay
Catalog Number

Overload Relay
with Ground Fault
Catalog Number

1

300: 5 panel-mount CT kit
with integrated lugs

ZEB-XCT300

750 kcmil
(2) 250 kcmil
3/0 Cu/Al

XTOE005CCSS

XTOE005CGSS

1

120-600

600: 5 panel-mount CT kit
with integrated,
pass through holes

ZEB-XCT600

(2) 750 kcmil
3/0 Cu/Al

XTOE005CCSS

XTOE005CGSS

580–1000A

200-1000

1000: 5 panel-mount CT kit ZEB-XCT1000
with integrated,
pass through holes

(3) 750 kcmil
3/0 Cu/Al

XTOE005CCSS

XTOE005CGSS

1600A

300-1500

1500: 5 panel-mount CT kit ZEB-XCT1500
with integrated,
pass through holes

(4) 750 kcmil
1/0 Cu/Al

XTOE005CCSS

XTOE005CGSS

Description

1

Frame
Size

Contact
Sequence

45 mm

1 3 5 97 95

1–5
4–20

2 4 6 98 96

9–45

Type

Overload Relay
Catalog Number

Overload Relay
with Ground Fault
Catalog Number

1
1

ZEB32-1,65/KK

XTOE1P6CCSS

XTOE1P6CGSS

ZEB32-5/KK

XTOE005CCSS

XTOE005CGSS

ZEB32-20/KK

XTOE020CCSS

XTOE020CGSS

ZEB32-45/KK

XTOE045CCSS

XTOE045CGSS

20–100

55 mm

ZEB150-100/KK

XTOE100GCSS

XTOE100GGSS

35–175

110 mm

ZEB150-175/KK

XTOE175GCSS

XTOE175GGSS

1
1
1
1
1

XT Electronic Overload Relay for Pass-Through Design
Pass-through design does not include any lugs to land wires.
Terminate motor leads directly on contactor.
Overload
Range (Amps)

Frame
Size

35–175

110 mm

Contact
Sequence

1 3 5 97 95

1
1

Overload Relay
0.33–1.65

1
1

XT Electronic Overload Relays for Separate Mount
Overload
Range (Amps)

1

1

Type

Overload Relay
Catalog Number

Overload Relay
with Ground Fault
Catalog Number

ZEB150-175/PT

XTOE175GCSP

XTOE175GGSP

1
1
1

2 4 6 98 96

1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-145

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Accessories
CT Kits

1
1

Accessories
Description

Catalog Number

Safety Cover

Safety Cover

Clear Lexan cover that mounts on top of the FLA dial and DIP switches when closed.

1

ZEB-XSC

1
1
1

Reset Bar

Reset Bar
Assembles to the top of the overload to provide a larger target area for door
mounted reset operators.

1

ZEB-XRB

1
1
1

Remote Reset

Remote Reset

1

Remote reset module (24 Vdc) 1

C440-XCOM

Remote reset module (120 Vac) 1

ZEB-XRR-120

Remote reset module (24 Vac) 1

ZEB-XRR-24

1
1
1
1
1
1
1
1
1
1
1
1

Communication
The C440 is provided with two levels of communication capability.
Advanced
Basic Communication via
Communication—
Expansion Module—
Monitoring and Control
Monitoring Only
C440 also has the ability to
Basic communication on
communicate on industrial
the C440 is accomplished
protocols such as DeviceNet,
using an expansion module.
PROFIBUS, Modbus RTU and
The expansion module plugs
Modbus TCP, and Ethernet
into the expansion bay on
(planned) while providing
the C440 overload relay,
control capability using I/O.
enabling communications
with the overload via their
An expansion module
Modbus RTU (RS-485)
(mentioned earlier) combined
network. No additional parts
with a communication
are required. See
adapter and a communication
figure below.
module allows easy
integration onto the
customer’s network. See
figure below.

Advanced
Communication—
Communication Module
The communication adapter
comes standard with four
inputs and two outputs
(24 Vdc or 120 Vac) while
providing the customer with
flexible mounting options
(DIN rail or panel). See
figure below,

1
1
1
1

Basic Communication—
Modbus
Advanced Communication—
Communication Adapter with
Communication Module

1
1

Note
1 Customer can wire remote mounted button to reset module (i.e., 22 mm pushbutton, catalog number M22-D-B-GB14-K10).

V5-T1-146

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

The following information can be viewed using the communication option:
●
●
●
Motor status—running,
Percent thermal capacity
Overload relay settings—
stopped, tripped or
trip class, DIP switch
●
Fault codes (only available
resetting
selections, reset selections
prior to reset)
●
●
Individual rms phase
Modbus address (can be
●
Percent phase unbalance
currents (A, B, C)
set over the network)
●
Ground fault current and
●
Average of three-phase
percent
rms current

1
1
1
1
1

Communication Accessories
Expansion Module

Description

Catalog Number

Expansion module (Remote Reset/Modbus RTU, RS-485 Communication)

C440-XCOM

1
1
1
1
1

Communication
Adapter

Communication adapter kit (DIN C Panel mounted adapter, required for advance communication option)

1

C440-COM-ADP

1
1
1
1
1
DeviceNet communication module kit—120V I/O (consists of C440-XCOM + C441K + C440-COM-ADP)

C440-DN-120

DeviceNet communication module kit—24 Vdc I/O (consists of C440-XCOM + C441L + C440-COM-ADP)

C440-DN-24

PROFIBUS communication module kit—120V I/O (consists of C440-XCOM + C441S + C440-COM-ADP)

C440-DP-120

PROFIBUS communication module kit—24V I/O (consists of C440-XCOM + C441Q + C440-COM-ADP)

C440-DP-24

Modbus communication module kit—120V I/O (consists of C440-XCOM + C441N + C440-COM-ADP)

C440-MOD-120

Modbus communication module kit—24 Vdc I/O (consists of C440-XCOM + C441P + C440-COM-ADP)

C440-MOD-24

Modbus TCP/Ethernet IP communication module kit—120V I/O (consists of C440-XCOM + C441U)

C440-ET-120

Modbus TCP/Ethernet IP communication module kit—24V I/O (consists of C440-XCOM + C441V)

C440-ET-24

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-147

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Modbus Communication Module
The Modbus module
combined with an expansion
module and a communication
adapter provide Modbus
communication capability to
the C440 electronic overload
relay.

1
1
1
1
1

Modbus
Communication Module

Features and Benefits
The Modbus
communication module is
capable of baud rates
up to 115K
●
The Modbus address and
baud rate configuration can
be easily changed using
the HMi user interface
●
Modbus address and baud
rate are set via convenient
DIP switches; LEDs are
provided to display
Modbus traffic
●
Configuration with
common Modbus
configuration tools
●

Terminals
●
Unique locking
mechanism provides for
easy removal of the
terminal block with the
field wiring installed
●
Each terminal is marked
for ease of wiring and
troubleshooting
Selectable I/O assemblies
●
4IN/2OUT
●
Signal types include
24 Vdc I/O and
120 Vac I/O

●

●

Terminals
●
Unique locking
mechanism provides for
easy removal of the
terminal block with the
field wiring installed
●
Each terminal is marked
for ease of wiring and
troubleshooting

●

●

Selectable I/O assemblies
●
4IN/2OUT
●
Signal types include
24 Vdc I/O and
120 Vac I/O

●

●

●

●

1
1
1
1
1
1
1
1

DeviceNet Communication Modules
The DeviceNet
Features and Benefits
Communication Module
●
Communication to
provides monitoring and
DeviceNet uses only one
control for the C440 overload
DeviceNet MAC ID
relay from a single DeviceNet
●
Configuration
node. These modules also
●
DeviceNet MAC ID and
offer convenient I/O in two
Baud rate are set via
voltage options,
convenient DIP switches
24 Vdc and 120 Vac.
with an option to set
from the network
●
Advanced configuration
available using common
DeviceNet tools

1
1

1
1
1
1
1
1

●

PROFIBUS Communication Modules
The PROFIBUS module
Features and Benefits
combined with an expansion
●
The PROFIBUS
module and a communication
communication module is
adapter provide Modbus
capable of baud rates
communication capability to
up to 12 Mb
the C440 electronic overload
●
PROFIBUS address is
relay.
set via convenient DIP
switches; LEDs are
provided to display
PROFIBUS status
●
Intuitive configuration
with common PROFIBUS
configuration tools

1
1

●

DeviceNet
Communication Module

1
1

●

●

●

Terminals
●
Unique locking
mechanism provides for
easy removal of the
terminal block with the
field wiring installed
●
Each terminal is marked
for ease of wiring and
troubleshooting
Selectable I/O assemblies
●
4IN/2OUT
●
Signal types include
24 Vdc I/O and
120 Vac I/O

PROFIBUS
Communication Module

1
V5-T1-148

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Each I/O module is
optically isolated
between the field I/O
and the network adapter
to protect the I/O and
communication circuits
from possible damage
due to transients and
ground loops
Input Module features a
user-definable input
debounce, which limits
the effects of transients
and electrical noise
Output Module supports
a user-definable safe
state for loss of
communication; hold
last state, ON or OFF

Each I/O module is
optically isolated
between the field I/O
and the network adapter
to protect the I/O and
communication circuits
from possible damage
due to transients and
ground loops
Input Module features a
user-definable input
debounce, which limits
the effects of transients
and electrical noise
Output Module supports
a user-definable safe
state for loss of
communication; hold
last state, ON or OFF

Combined status LED

●

●

●

Each I/O module is
optically isolated
between the field I/O
and the network adapter
to protect the I/O and
communication circuits
from possible damage
due to transients and
ground loops
Input Module features a
user-definable input
debounce, which limits
the effects of transients
and electrical noise
Output Module supports
a user-definable safe
state for loss of
communication; hold
last state, ON or OFF

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Technical Data and Specifications

1

Electronic Overload Relays up to 1500A

1

Specification
Description

45 mm

55 mm

110 mm

Electrical Ratings

Range

Range

Range

Operating voltage (three-phase) and frequency

690 Vac (60/50 Hz)

690 Vac (60/50 Hz)

690 Vac (60/50 Hz)

1

0.33–1.65A
1–5A
4–20A
9–45A

20–100A

28–140A (NEMA)
35–175A (IEC)

1

XT IEC frames

B, C, D

F, G

G, H

Freedom NEMA sizes

00, 0, 1, 2

3

4

1

10A, 10, 20, 30
Selectable

10A, 10, 20, 30
Selectable

10A, 10, 20, 30
Selectable

1

Thermal overload setting

1.05 x FLA: does not trip
1.15 x FLA: overload trip

1.05 x FLA: does not trip
1.15 x FLA: overload trip

1.05 x FLA: does not trip
1.15 x FLA: overload trip

Feature

Range

Range

Range

Phase loss

Fixed threshold 50%

Fixed threshold 50%

Fixed threshold 50%

Phase unbalance (selectable: enable/disable)

Fixed threshold 50%

Fixed threshold 50%

Fixed threshold 50%

Ground fault (selectable: enable/disable)

50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec

50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec

50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec

Reset

Manual/automatic

Manual/automatic

Manual/automatic

Trip status

Orange flag

Orange flag

Orange flag

Mode LED

One flash: Overload operating properly
Two flashes: Current is above FLA dial
setting—pending trip

One flash: Overload operating properly
Two flashes: Current is above FLA dial
setting—pending trip

One flash: Overload operating properly
Two flashes: Current is above FLA dial
setting—pending trip

1

FLA Range

1

Use with Contactors

1

Trip Class

Motor Protection

1
1
1
1
1
1

Indicators

Options

1
1
1

Remote reset

Yes

Yes

Yes

Reset bar

Yes

Yes

Yes

Communication expansion module

Yes

Yes

Yes

Communication adapter

Yes

Yes

Yes

Terminal capacity

12–10 AWG (4–6 mm2)
8–6 AWG (6–16 mm2)

6–1 AWG (16–50 mm2)

8–4/0 AWG (10–95 mm2)

Tightening torque

20–25 lb-in (2.3–2.8 Nm)
25–30 lb-in (2.8–3.4 Nm)

25–30 lb-in (2.8–3.4 Nm)

124 lb-in (14 Nm)

Terminal capacity

2 x (18–12) AWG

2 x (18–12) AWG

2 x (18–12) AWG

Tightening torque

7–11 lb-in (0.8–1.2 Nm)

7–11 lb-in (0.8–1.2 Nm)

7–11 lb-in (0.8–1.2 Nm)

Insulation voltage U i (three-phase)

690 Vac

690 Vac

690 Vac

Insulation voltage U i (control)

500 Vac

500 Vac

500 Vac

Rated impulse withstand voltage

6000 Vac

6000 Vac

6000 Vac

Overvoltage category/pollution degree

III/3

III/3

III/3

1
1

Capacity

1

Load terminals

1
1

Input, auxiliary contact and remote reset terminals

1
1

Voltages

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-149

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Electronic Overload Relays up to 1500A, continued
Specification

1

Description

1

Conventional thermal continuous current

1

45 mm

55 mm

110 mm

5A

5A

5A

Auxiliary and Control Circuit Ratings

Rated operational current—IEC AC-15
Make contact (1800 VA)

1

120V

15A

15A

15A

240V

15A

15A

15A

1

415V

0.5A

0.5A

0.5A

500V

0.5A

0.5A

0.5A

120V

1.5A

1.5A

1.5A

240V

1.5A

1.5A

1.5A

415V

0.9A

0.9A

0.9A

500V

0.8A

0.8A

0.8A

1.0A

1.0A

1.0A

120V

30A

30A

30A

1

240V

15A

15A

15A

480V

7.5A

7.5A

7.5A

1

600V

6A

6A

6A

120V

3A

3A

3A

1

240V

1.5A

1.5A

1.5A

480V

0.75A

0.75A

0.75A

1

600V

0.6A

0.6A

0.6A

1
1
1
1
1
1

1

1
1

Break contact (180 VA)

IEC DC-13 (L/R F 15 ms1)
0–250V
Rated operational current—UL B600
Make contact (3600 VA)

Break contact (360 VA)

R300—Vdc ratings (28 VA)
0–120V

0.22A

0.22A

0.22A

250V

0.11A

0.11A

0.11A

6A gG/gL

6A gG/gL

6A gG/gL

–13° to 149°F (–25° to 65°C)

Short-Circuit Rating without Welding

1

Maximum fuse

1

Ambient temperature (operating)

–13° to 149°F (–25° to 65°C)

–13° to 149°F (–25° to 65°C)

Ambient temperature (storage)

–40° to 185°F (–40° to 85°C)

–40° to 185°F (–40° to 85°C)

–40° to 185°F (–40° to 85°C)

1

Operating humidity UL 991 (H3)

5% to 95% non-condensing

5% to 95% non-condensing

5% to 95% non-condensing

1

Environmental Ratings

Altitude (no derating) NEMA ICS1

2000m

2000m

2000m

Shock (IEC 600068-2-27)

15g any direction

15g any direction

15g any direction

1

Vibration (IEC 60068-2-6)

3g any direction

3g any direction

3g any direction

Pollution degree per IEC 60947-4-1

3 for product (2 for pcb)

3 for product (2 for pcb)

3 for product (2 for pcb)

1

Ingress protection

IP20

IP20

IP20

Protection against direct contact when actuated from
front (IEC 536)

Finger- and back-of-hand proof

Finger- and back-of-hand proof

Finger- and back-of-hand proof

Mounting position

Any

Any

Any

Climatic proofing

Damp heat, constant to IEC 60068-2-30

Damp heat, constant to IEC 60068-2-30

Damp heat, constant to IEC 60068-2-30

1
1
1
1
1

V5-T1-150

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Electronic Overload Relays up to 1500A, continued

1

Specification
Description

45 mm

55 mm

110 mm

1

Radiated emissions
IEC 60947-4-1-Table 15
EN 55011 (CISPIR 11) Group 1, Class A, ISM

30 mHz to 1000 mHz

30 mHz to 1000 mHz

30 mHz to 1000 mHz

1

Conducted emissions
IEC 60947-4-1-Table 14
EN 55011 (CISPIR 11) Group 1; Class ISM

0.15 mHz to 30 mHz

0.15 mHz to 30 mHz

0.15 mHz to 30 mHz

ESD immunity
IEC 60947-4-1 (Table 13)

±8 kV air, ±6 kV contact

±8 kV air, ±6 kV contact

±8 kV air, ±6 kV contact

Radiated immunity
IEC 60947-4-1
IEC 61000-4-3

10 V/m 80 mHz–1000 mHz
3 V/m from 1.4 to 2.7 gHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80 mHz–1000 mHz
3 V/m from 1.4 to 2.7 gHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80 mHz–1000 mHz
3 V/m from 1.4 to 2.7 gHz
80% amplitude modulated
1 kHz sine wave

Conducted immunity
IEC 60947-4-1, IEC 61000-4-6

140 dub (10V rms)
150 kHz–100 mHz

140 dub (10V rms)
150 kHz–100 mHz

140 dub (10V rms)
150 kHz–100 mHz

Fast transient immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-4

±4 kV using direct method
with accessory installed in expansion bay
±2 kV using direct method

±4 kV using direct method
with accessory installed in expansion bay
±2 kV using direct method

±4 kV using direct method
with accessory installed in expansion bay
±2 kV using direct method

Surge immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-5 a Class 4

Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)

Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)

Three-phase power inputs:
±4 kV line-to-line (DM)
±4 kV line-to-ground (CM)

With accessory installed in expansion bay:
±2 kV line-to-line (DM) –>1.2/50 us;
2 kV line-to-earth, 1 kV line-to-line
±4 kV line-to-ground (CM)

With accessory installed in expansion bay:
±2 kV line-to-line (DM) –>1.2/50 us;
2 kV line-to-earth, 1 kV line-to-line
±4 kV line-to-ground (CM)

With accessory installed in expansion bay:
±2 kV line-to-line (DM) –>1.2/50 us;
2 kV line-to-earth, 1 kV line-to-line
±4 kV line-to-ground (CM)

Power freq. magnetic field immunity
IEC 60947-4-1, IEC 61000-4-8

30 A/m, 50 Hz

30 A/m, 50 Hz

30 A/m, 50 Hz

Electromagnetic field
IEC 60947-4-1 Table 13, IEC 61000-4-3

10 V/m

10 V/m

10 V/m

Distortion IEEE 519

5% THD max., 5th harmonic 3% max.

5% THD max., 5th harmonic 3% max.

5% THD max., 5th harmonic 3% max.

Electrostatic discharge (ESD)
IEC 61000-4-2, EN 61131-2

4 kV contact
8 kV air discharge

4 kV contact
8 kV air discharge

4 kV contact
8 kV air discharge

1

Electrical fast transient (EFT)
IEC 61000-4-4, EN 61131-2

±2 kV using direct method

±2 kV using direct method

±2 kV using direct method

1

Surge immunity
IEC 61000-4-5, EN 61131-2

±2 kV line-to-ground (CM)

±2 kV line-to-ground (CM)

±2 kV line-to-ground (CM)

1

Electrical/EMC

1
1
1
1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-151

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Communication Modules
Description

Modbus

DeviceNet

PROFIBUS

Ethernet

Radiated emissions
IEC 60947-4-1—Table 15, EN 55011
(CISPIR 11) Group 1, Class A

30–1000 mHz

30–1000 mHz

30–1000 mHz

30–1000 mHz

Conducted emissions
IEC 60947-4-1—Table 14, EN 55011
(CISPIR 11) Group 1, Class A

0.15–30 mHz

0.15–30 mHz

0.15–30 mHz

0.15–30 mHz

ESD immunity
IEC 60947-4-1 (Table 13)

±8 kV air, ±4 kV contact

±8 kV air, ±4 kV contact

±8 kV air, ±4 kV contact

±8 kV air, ±4 kV contact

Radiated immunity
IEC 60947-4-1

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

10 V/m 80–1000 mHz
80% amplitude modulated
1 kHz sine wave

Conducted immunity
IEC 60947-4-1

140 dBuV (10V rms)
150 kHz–80 mHz

140 dBuV (10V rms)
150 kHz–80 mHz

140 dBuV (10V rms)
150 kHz–80 mHz

140 dBuV (10V rms)
150 kHz–80 mHz

Fast transient immunity
IEC 60947-4-1 (Table 13) IEC 6100-4-4

±2 kV using direct method

±2 kV supply and control,
±1 kV communication

±2 kV supply and control,
±1 kV communication

±2 kV supply and control,
±1 kV communication

Surge immunity
IEC 60947-4-1 (Table 13)
IEC 61000-4-5 Class 3

User IO and communication lines 1:
±1 kV line-to-line (DM)
±2 kV line-to-ground (CM)

User IO and communication lines:
±0.5 kV line-to-line (DM)
±1 kV line-to-ground (CM)

User IO and communication lines:
±0.5 kV line-to-line (DM)
±1 kV line-to-ground (CM)

User IO and communication lines:
±0.5 kV line-to-line (DM)
±1 kV line-to-ground (CM)

Electromagnetic field 1
IEC 60947-4-1 (Table 13) IEC 61000-4-3

10 V/m

10 V/m

10 V/m

10 V/m

Electrical/EMC

Environmental Ratings

1

Ambient temperature (operating)

–4° to 122°F (–20° to 50°C)

–13° to 122°F (–25° to 50°C)

–13° to 122°F (–25° to 50°C)

–13° to 122°F (–25° to 50°C)

1

Ambient temperature (storage)

–40° to 185°F (–40° to 85°C)

–40° to 185°F (–40° to 85°C)

–40° to 185°F (–40° to 85°C)

–40° to 185°F (–40° to 85°C)

Operating humidity

5–95% noncondensing

5–95% noncondensing

5–95% noncondensing

5–95% noncondensing

Altitude (no derating)

2000m

2000m

2000m

2000m
15G any direction

1

Shock (IEC 600068-2-27)

15G any direction

15G any direction

15G any direction

Vibration (IEC 60068-2-6)

3G any direction

3G any direction

3G any direction

3G any direction

Pollution degree per IEC 60947-1

3

3

3

3

1

Degree of protection

IP20

IP20

IP20

IP20

Overvoltage category per UL 508

III

III

III

III

1

DeviceNet
DeviceNet connections

—

Group 2, polling, bit strobe,
explicit, no UCMM

—

Group 2, polling, bit strobe,
explicit, no UCMM

DeviceNet baud rate

—

125K, 250K, 500K

—

125K, 250K, 500K

Ethernet connections

—

—

—

Integrated two-port switch with dual
RJ45 Ethernet connections

Ethernet type

—

—

—

Ethernet 10/100 Mbs, AutoMDX,
Auto Negotiation

PROFIBUS connections

—

—

Group 2, polling, bit strobe,
explicit, no UCMM

—

PROFIBUS baud rate

—

—

9.6K, 19.2K, 45.45K, 93.75K, 187.5K, —
500K, 1.5M, 3M, 6M, 12M

1

1
1
1
1
1
1
1
1

Ethernet

PROFIBUS

Note
1 Relates to C441M only.

1
1
1
1
1
V5-T1-152

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Communication Modules, continued
Description

Modbus

DeviceNet

PROFIBUS

Ethernet

Nominal input voltage

24 Vdc

24 Vdc

24 Vdc

24 Vdc

Operating voltage

18–30 Vdc

18–30 Vdc

18–30 Vdc

18–30 Vdc

Number of inputs

4

4

4

4

1
1

C441_ 24 Vdc Input

1

Signal delay

5 ms (programmable to 65 sec)

5 ms (programmable to 65 sec)

5 ms (programmable to 65 sec)

5 ms (programmable to 65 sec)

OFF-state voltage

<6 Vdc

<6 Vdc

<6 Vdc

<6 Vdc

ON-state voltage

>18 Vdc

>18 Vdc

>10 Vdc

>18 Vdc

Nominal input current

5 mA

5 mA

5 mA

5 mA

Isolation

1500V

1500V

1500V

1500V

Terminal screw torque

7–9 in-lb

7–9 in-lb

7–9 in-lb

7–9 in-lb

24V source current

50 mA

50 mA

50 mA

50 mA

0–6 Vdc

0–6 Vdc

0–6 Vdc

1
1
1
1
1

Operating Voltage Range—DC Input Modules
OFF state

0–6 Vdc

Transition region

6–18 Vdc

6–18 Vdc

6–18 Vdc

6–18 Vdc

ON state

18–30 Vdc

18–30 Vdc

18–30 Vdc

18–30 Vdc

Nominal input voltage

120 Vac

120 Vac

120 Vac

120 Vac

Operating voltage

80–140 Vac

80–140 Vac

80–140 Vac

80–140 Vac

Number of inputs

4

4

4

4

OFF-state voltage

<30 Vac

<30 Vac

<20 Vac

<30 Vac

ON-state voltage

>80 Vac

>80 Vac

>70 Vac

>80 Vac

Nominal input current

15 mA

15 mA

15 mA

15 mA

Signal delay

1/2 cycle

1/2 cycle

1/2 cycle

1/2 cycle

Isolation

1500V

1500V

1500V

1500V

Terminal screw torque

7–9 in-lb

7–9 in-lb

7–9 in-lb

7–9 in-lb

1

0–30 Vac

0–30 Vac

0–30 Vac

1

1
1

C441_ 120 Vac Input

1
1
1
1

Operating Voltage Range—AC Input Modules
OFF state

0–30 Vac

Transition region

30–80 Vac

30–80 Vac

30–80 Vac

30–80 Vac

ON state

80–140 Vac

80–140 Vac

80–140 Vac

80–140 Vac

Nominal voltage

120 Vac
24 Vdc

120 Vac
24 Vdc

120 Vac
24 Vdc

120 Vac
24 Vdc

Number of outputs

(2) 1NO Form A
1NO/NC Form C

(2) 1NO Form A
1NO/NC Form C

(2) 1NO Form A
1NO/NC Form C

(2) 1NO Form A
1NO/NC Form C

Relay OFF time

3 ms

3 ms

3 ms

3 ms

Relay ON time

7 ms

7 ms

7 ms

7 ms

Max. current per point 1

5A (B300 rated)

5A (B300 rated)

5A (B300 rated)

5A (B300 rated)

Electrical life

100,000 cycles

100,000 cycles

100,000 cycles

100,000 cycles

Mechanical life

1,000,000 cycles

1,000,000 cycles

1,000,000 cycles

1,000,000 cycles

1

Output Modules

1
1
1
1
1
1

Note
1 Relates to C441M only.

1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-153

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1

XT IEC Power Control

Short Circuit Ratings (North America CSA, cUL)
Changes to UL 508A and NEC in recent years have brought a focus to control panel safety with
regard to short-circuit current ratings (SCCR). Eaton’s C440 electronic overload relays combined
with XT series IEC and Freedom Series NEMA contactors provide a wide variety of SCCR
solutions needed for a variety of applications. The SCCR data in this document reflects the
latest information as of April 2010.
C440/XT Standalone Overload Relays (XT, C440)
Standard-Fault Short Circuit Data

1
1

IEC Contactors and Starters

Overload
FLA Range

Maximum
Operating
Voltage

600V (kA)

Maximum
Fuse Size (A)
(RK5)

High-Fault Short Circuit Data

Maximum
Breaker
Size (A)

Fuses (RK5, J, CC)
480V (kA)

Thermal-Magnetic Circuit Breakers

600V (kA)

Maximum
Fuse Size

480V (kA)

600V (kA)

Maximum
Breaker Size

0.33–1.65A

600 Vac

1

6

15

—

—

—

—

—

—

1–5A

600 Vac

5

20

20

100

100

30

100

35

20

1

4–20A

600 Vac

5

80

80

100

100

100

100

35

80

9–45A

600 Vac

5

175

175

100

100

100

100

35

100/175 (480/600)

1

20–100A

600 Vac

10

400

400

100

100

200

150

35

250/400 (480/600)

28–140A

600 Vac

10

450

500

100

100

400

100

65

400

35–175A

690 Vac

10

500 (gG)

350 (690 Vac)
320 (415 Vac)

100

100

500 (gG)

100 (415 Vac)

—

350 (LGC3350)
320 (NZMH3)

1

1
1
1

IEC XT Starters with XT Electronic Overload Relays
Contactor
Frame Size

Maximum
Operating
Voltage

High-Fault Short Circuit Data

1

Fuses (RK5, J, CC)
480V

1

B

1–5A

1

4–20A
C

1
1

D

1

F

1
1

G

H

Thermal-Magnetic Circuit Breakers

600V

Maximum
Fuse Size

480V

600V

Maximum
Breaker Size

100

100

30

—

—

—

100

100

30

—

—

—

1–5A

100

100

60

—

—

—

4–20A

100

100

60

—

—

—

9–45A

100

100

60

—

—

—

9–45A

100

100

200

65

35

175

20–100A

100

100

200

65

35

175

20–100A

100

100

200

65

65

350

20–100A

100

100

200

65

65

350

35–175A

100

100

400

65

30

250 (480 Vac)
350 (600 Vac)

35–175A

100

100

400

65

30

400

1
1
1
1
1
1
1
1
1
1
V5-T1-154

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Dimensions
Approximate Dimensions in Inches (mm)

1

45 mm C440/XT Electronic Overload Relays

1

A

1
1
1
1
1
1
1

C

Text Orientation

1
1
1
1

B1

1

B
Width
A

1

Depth
B1

B

Mounting Holes
(Height) C

4.32 (109.7)

4.63 (117.5)

3.68 (93.5)

1.80 (45.7)

4.00 (101.6)

4.30 (109.2)

3.68 (93.5)

1

1.80 (45.7)

4.30 (109.2)

4.60 (116.8)

3.68 (93.5)

1

1

NEMA Starter Size
00–2

1.80 (45.7)

1

XT IEC Frame Size
B, C, D
Standalone
0.35–45A

1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-155

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in Inches (mm)
55 mm C440/XT Electronic Overload Relays

1
1

B

1

B1

C

1
1
1

A

1
1

NEMA Starter Size

1

XT IEC Frame Size

1
1
1

3

D, F, G

Width
A

Height To Reset
B

B1

Mounting Depth
C

2.21 (56.0)

5.52 (140.2)

5.21 (132.4)

4.13 (104.8)

2.21 (56.0)

5.52 (140.2)

5.21 (132.4)

4.13 (104.8)

2.21 (56.0)

5.52 (140.2)

5.21 (132.4)

4.13 (104.8)

Standalone
20–100A

110 mm C440/XT Electronic Overload Relays
B1

1
1
1
C

1
1
1
1

B

A

1

Width
A

Height To Reset
B

B1

Mounting Depth
C

4.33 (110.0)

6.20 (157.0)

5.90 (150.0)

6.00 (152.0)

1

NEMA Starter Size

1

XT IEC Frame Size
G

4.33 (110.0)

6.20 (157.0)

5.90 (150.0)

6.00 (152.0)

1

H

4.33 (110.0)

6.20 (157.0)

5.90 (150.0)

6.00 (152.0)

4.33 (110.0)

6.20 (157.0)

5.90 (150.0)

6.00 (152.0)

4.33 (110.0)

5.90 (149.0)

5.60 (142.0)

4.00 (102.0)

1
1

4

Standalone

Pass-Through

1
1
1
V5-T1-156

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Contents

Manual Motor Protectors

Description

Page

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . .
Manual Motor Protectors
Features and Benefits . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Product Identification . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

V5-T1-3
V5-T1-18
V5-T1-35
V5-T1-128
V5-T1-141

1

V5-T1-158
V5-T1-158
V5-T1-159
V5-T1-160
V5-T1-161
V5-T1-164
V5-T1-176
V5-T1-185
V5-T1-193
V5-T1-216
V5-T1-229

1

1
1
1
1
1
1
1
1

Manual Motor Protectors
Product Description

Application Description

Eaton’s new XT family of
manual motor protectors
(MMPs) features a
pushbutton or rotary ON/OFF
manual disconnect, Class 10
adjustable bimetallic overload
relay and fixed magnetic
short-circuit trip capability
in one compact unit. Two
frame sizes are available:
Frame B (45 mm) for motors
with FLA ratings up to 32A
and Frame D (55 mm) covers
motor FLA ratings up to 65A.

The XTPB and XTPR MMPs
can be used in the following
applications.

1
1

Motor Protective Circuit Breaker
In many countries outside
of the United States and
Canada, especially Europe,
the MMPs are tested and
classified as thermalmagnetic circuit breakers
for use in motor branch
circuits. This can be an
important consideration for all
companies who export their
equipment and machines
internationally. Both the XTPB
and XTPR conform to IEC/EN
60947 and have the CE Mark.

Group Motor Installations
A group motor installation
can be defined as more than
one motor circuit protected
by a single set of fuses or
circuit breaker on a motor
branch circuit. This eliminates
the need for individual fuses
or circuit breakers for each
motor circuit. Substantial
component cost savings,
panel space savings and
reduced wiring installation
time can be achieved in
group motor installations.

Manual Motor Protectors
The XTPB and XTPR MMPs
are UL listed under UL 508 as
manual motor protectors. They
provide an economical solution
for applications requiring
simple manual starting and
stopping of motors. When
used as a manual starter, they
are typically installed in an
enclosure. Many enclosures
are offered as accessories for
the MMPs. Separate shortcircuit protective devices, such
as circuit breakers or fuses, are
wired ahead of the MMPs. The
short-circuit protective device
should be sized per the NEC
and should not exceed 400%
of the maximum FLA dial
setting of the MMP.

The MMPs are tested and
listed for group installation.
If remote operation is required,
a magnetic contactor can be
wired in series with the MMP.
Article 430.53 of the NEC
contains the rules and
requirements for group motor
installations. Refer to
application note AP03402001E
for NEC requirement for
group motor installation.

Volume 5—Motor Control and Protection

Individual Branch Motor
Applications
A UL 508 Type E selfprotected manual
combination starter/motor
controller consists of a single
device possessing four
essential elements:
disconnect, short circuit
protection, motor controller,
and motor overload
protection. Some MMPs
require use of a lineside
adapter for this type of
approval. When tested as an
official combination by UL,
this device takes the place of
a fuse-starter or breakerstarter, XT Type E MMPs are
self-protected, meaning they
do not need additional short
circuit protection of a fuse or
breaker. Type E devices can
also be used with a contactor
or other types of UL approved
controllers. If tested with a
contactor, the combination
motor controller becomes a
Type F device. See Page
V5-T1-199 for XTFC Type F
devices.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

CA08100006E—August 2012

www.eaton.com

V5-T1-157

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1

●

●
●

●
●

●

1

●

1

●

1
1
1

XT IEC Power Control

Features and Benefits

1
1

IEC Contactors and Starters

●

●

1

ON/OFF rotary handle with
lockout provision
Visible trip indication
Class 10 overload
protection
Phase loss sensitivity
Ambient temperature
compensation to IEC/EN
60947, VDE 0660
Fixed short-circuit trip—
14 times maximum setting
of overload FLA dial
Type 2 coordination per IEC
947
Identification markers
standard on starter
faceplate
Motor applications from
0.1A to 65A
Built-in heater and
magnetic trip elements
to protect the motor

Line Side Adapters—When to Use Them
●

●
●

●

Adjustment dial for setting
motor FLA
DIN rail mount
Terminal types available:
●
Screw terminals
●
Screw (line) and spring
cage (load) terminals
●
Spring cage terminals
Accessories include:
●
Front and side auxiliary
contacts
●
Trip indicating contacts
●
Tamperproof cover for
OLR dial
●
Undervoltage release
●
Shunt trip
●
Through-the-door
operators
●
Enclosures
●
Three-phase line side
connecting links

Note: Line side adapters are not required for non-US applications.
Most countries outside of the US classify the MMP as a thermal
magnetic circuit breaker.

Manual Motor Protectors
Self-Protected Manual Combination Starters

Group Installation
Upstream SCPD required.

Line Side Adapter (LSA)
Not required

1
1
1
1

Standards and Certifications
●
●
●

●

1

●

1

●

Manual Motor Protector
and Line Side Adapter

CE approved
UL listed File No. E245398
UL 508 group motor and
Type E compliant
IEC/EN 60947
CSA File 229767, Class
3211-05
DIN VDE 0660 Part 100,
Part 101 and Part 102

1
1
1

Note: For Type 2 Coordination
of MMCs, see Page V5-T1-230.

1
1
1
1
1
1
1
1
1
V5-T1-158

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

UL 508 Type E Self-Protected Manual
Combination Starter
Self-protected. No additional SCPD needed in
branch circuit.

Line Side Adapter (LSA)
Required

Line Side Adapter
XTPAXLSA

Line Side Adapter
XTPAXLSAD

MMP
XTPR…BC1

MMP
XTPR…DC1

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Product Identification

1
1

1

1
4

1
1
1

2

1
1
1
5

5

1

3

1
1
5

1
1
1

2
2

1

6

1
1

6

1
1
Notes
Basic Units
1 XTPB pushbutton manual motor
protectors (see Page V5-T1-161)
Rated operational current up to 25A
Switching capacity 50 kA/415V
Short-circuit release, adjustable
0.6–1 x lu
Single-phasing sensitive
2 XTPR rotary manual motor protectors
(see Page V5-T1-162)
Rated operational current up to
32A, 65A
Switching capacity 150/50 kA/415V
Short-circuit release, fixed setting to
14 x lu
Overload release, adjustable 0.6–1 x lu
Single-phasing sensitive
With screws or spring-loaded
terminals

1
Mounting Accessories
Rotary handle mechanism
(see Page V5-T1-167)
ON/OFF/tripped switch position indication
Lockable door/cover interlock
Extendable y plug fit extension shaft
Handle latched in switch positions
Optionally also without locking and
door interlock function

3

Insulated enclosures
(see Page V5-T1-171)
Surface mounting, enclosures, IP40,
IP55 and IP40 and IP55 front flush
mounting enclosure
Mounting/wiring (see Page V5-T1-167)
Component adapter for busbar mounting
Three-phase commoning link for
side-by-side-mounting
Mounting kits for rapid mounting of
direct-on-line, reversing and stardelta starters

Add-On Functions
4 Voltage releases (see Page V5-T1-166)
Undervoltage release
Shunt releases
With screws or spring-loaded terminals
5 Standard auxiliary contacts
(see Page V5-T1-164)
ON/OFF indication
Differential fault indication overload/
short-circuit release
ON/OFF for (high capacity) contact
module
ON/OFF for starter combination
With early-make contacts
With screws or spring-loaded terminals
6 Current limiter (see Page V5-T1-166)
Increases the switching capacity of the
10–25A manual motor protectors to
100 kA/440V
Can be used for individual group
protection

Volume 5—Motor Control and Protection

1
1
1
1
1
1
1
1
1

CA08100006E—August 2012

www.eaton.com

V5-T1-159

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Catalog Number Selection
XT Manual Motor Protectors

XT PR 012 B C1

1
1

Designation
XT = XT IEC power control
PB =

1

PR

1

=

PM =

1

PT

=

Type
Manual motor protector—
pushbutton
Manual motor protector—
rotary
Manual motor protector—
magnetic only
Manual transformer
protector (high mag.)

1
1
1
1

Current Ratings
Frame B
Frame D
P16 = 0.16A
016 = 16A
P25 = 0.25A
025 = 25A
P40 = 0.40A
032 = 32A
P63 = 0.63A
040 = 40A
001 = 1A
050 = 50A
1P6 = 1.6A
058 = 58A
2P5 = 2.5A
063 = 63A
004 = 4A
6P3 = 6.3A
010 = 10A
012 = 12A
016 = 16A
020 = 20A
025 = 25A
032 = 32A

Frame Size
B
= 45 mm
D
= 55 mm

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-160

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Trip Class
C1
= Class 10
Blank = Magnetic only (no thermal trip)

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Product Selection

1

Product Selection for Manual Motor Starter Applications
When ordering, specify catalog numbers according to the following stipulations:
XT manual motor protectors
are selected based on the
overload current range
required for a given motor.
This current range is
determined from the motor
full load ampere rating and
motor service factor usually
found on the motor
nameplate.

1

For motors with service
factors less than 1.15,
multiply the motor FLA by
0.90 to select appropriate
MMP.

For motor with service
factor of 1.15 or greater,
use motor nameplate full load
amperes to select the
appropriate MMP.

Example: For motor having
FLA of 6.4A and service
factor of 1.0 (6.4A x 0.90 =
5.76A) select catalog number
XTPB6P3B01.

Example: For motor having
FLA of 11A and service factor
of 1.15, select catalog
number XTPR012BC1.

1
1
1
1
1

See Application Note—
AP03402001E.

1
1

Frame B

XTPB Pushbutton Manual Motor Protectors—Global and North American Ratings—Frame B
Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip

Rated
Uninterrupted
Current—
Iu = Ie (Amps)

FLA
Adjustment
Range/
Overload
Release—
Ir (Amps)

Short
Circuit
Release—
Irm (Amps)

1
1

Maximum Motor Ratings 1
Maximum kW Rating
AC-3—P (kW)

Maximum hp Rating—P (hp)
UL 508/CSA C22.2 No. 14

Three-Phase

Three-Phase

220–
240V

380–
415V

440V

500V

660–
690V

200V

240V

480V

600V

1
Screw Terminal
Catalog Number

0.16

0.1–0.16

2.2

—

—

—

—

0.06

2

2

2

2

XTPBP16BC1

0.25

0.16–0.25

3.5

—

0.06

0.06

0.06

0.12

2

2

2

2

XTPBP25BC1

0.4

0.25–0.4

5.6

0.06

0.09

0.12

0.12

0.18

2

2

2

2

XTPBP40BC1

2

2

2

XTPBP63BC1
XTPB001BC1

0.63

0.4–0.63

8.8

0.09

0.12

0.18

0.25

0.25

2

1

0.63–1

14

0.12

0.25

0.25

0.37

0.55

2

2

2

1/2

1.6

1–1.6

22

0.25

0.55

0.55

0.75

1.1

2

2

3/4

3/4

XTPB1P6BC1

2.5

1.6–2.5

35

0.37

0.75

1.1

1.1

1.5

1/2

1/2

1

1-1/2

XTPB2P5BC1

4

2.5–4

56

0.75

1.5

1.5

2.2

3

3/4

3/4

2

3

XTPB004BC1

6.3

4–6.3

88

1.1

2.2

3

3

4

1

1-1/2

3

5

XTPB6P3BC1

10

6.3–10

140

2.2

4

4

4

7.5

3

3

7-1/2

10

XTPB010BC1

12

8–12

168

3

5.5

5.5

5.5

11

3

3

7-1/2

10

XTPB012BC1

16

10–16

224

4

7.5

9

9

12.5

3

5

10

10

XTPB016BC1

20

16–20

280

5.5

9

11

12.5

15

5

—

—

15

XTPB020BC1

25

20–25

350

5.5

12.5

12.5

15

22

—

7-1/2

15

20

XTPB025BC1

Notes
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor:
SF = 1.15 → Ir = 1 x In mot
SF = 1 → Ir = 0.9 x In mot

1
1
1
1
1
1
1
1
1
1

For manual motor protective circuit breaker switching capacity, see Page V5-T1-181.
2

1

1

Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height.

1

1

Select manual motor protectors by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-161

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame B

1

IEC Contactors and Starters
XT IEC Power Control

XTPR Rotary Manual Motor Protectors with Screw Terminals—
Global Ratings and North American Ratings—Frame B
Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip

1
Rated
Uninterrupted
Current—
Iu = Ie (Amps)

1
1

FLA
Adjustment
Range/
Overload
Release—
Ir (Amps)

Short
Circuit
Release—
Irm (Amps)

Maximum Motor Ratings 1
Maximum kW Rating
AC-3—P (kW)

Maximum hp Rating—P (hp)
UL 508/CSA C22.2 No. 14

Three-Phase
220–
240V

380–
415V

Three-Phase
440V

500V

660–
690V

200V

240V

480V

600V

Screw Terminal
Catalog Number

0.16

0.1–0.16

2.2

—

—

—

—

0.06

2

2

2

2

XTPRP16BC1

0.25

0.16–0.25

3.5

—

0.06

0.06

0.06

0.12

2

2

2

2

XTPRP25BC1

0.4

0.25–0.4

5.6

0.06

0.09

0.12

0.12

0.18

2

2

2

2

XTPRP40BC1

0.63

0.4–0.63

8.8

0.09

0.12

0.18

0.25

0.25

2

2

2

2

XTPRP63BC1

1

1

0.63–1

14

0.12

0.25

0.25

0.37

0.55

2

2

2

2

XTPR001BC1

1.6

1–1.6

22

0.25

0.55

0.55

0.75

1.1

2

2

3/4

3/4

XTPR1P6BC1

1

2.5

1.6–2.5

35

0.37

0.75

1.1

1.1

1.5

1/2

1/2

1

1-1/2

XTPR2P5BC1

4

2.5–4

56

0.75

1.5

1.5

2.2

3

3/4

3/4

2

3

XTPR004BC1

6.3

4–6.3

88

1.1

2.2

3

3

4

1

1-1/2

3

5

XTPR6P3BC1

1

10

6.3–10

140

2.2

4

4

4

7.5

3

3

7-1/2

10

XTPR010BC1

12

8–12

168

3

5.5

5.5

5.5

11

3

3

7-1/2

10

XTPR012BC1

1

16

10–16

224

4

7.5

9

9

12.5

3

5

10

10

XTPR016BC1

20

16–20

280

5.5

9

11

12.5

15

5

—

—

15

XTPR020BC1

1

25

20–25

350

5.5

12.5

12.5

15

22

—

7-1/2

15

20

XTPR025BC1

32

25–32

448

7.5

15

15

22

30

7-1/2

10

20

25

XTPR032BC1

1
1

1

1
1

Frame D

1

XTPR Rotary Manual Motor Protectors with Screw Terminals—
Global Ratings and North American Ratings—Frame D
Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip

1
1

Rated
Uninterrupted
Current—
Iu = Ie (Amps)

1

FLA
Adjustment
Range/
Overload
Release—
Ir (Amps)

Short
Circuit
Release—
Irm (Amps)

Maximum Motor Ratings 1
Maximum kW Rating
AC-3—P (kW)

Maximum hp Rating—P (hp)
UL 508/CSA C22.2 No. 14

Three-Phase
220–
240V

380–
415V

Three-Phase
440V

500V

660–
690V

200V

240V

480V

600V

Screw Terminal
Catalog Number

1

16

10–16

224

4

7.5

9

9

12.5

3

5

10

15

XTPR016DC1

25

16–25

350

5.5

12.5

12.5

15

22

7-1/2

7-1/2

20

25

XTPR025DC1

1

32

25–32

448

7.5

15

17.5

22

22

10

10

25

30

XTPR032DC1

40

32–40

560

11

20

22

24

30

10

15

30

30

XTPR040DC1

1
1
1

50

40–50

700

14

25

30

30

45

10

15

30

40

XTPR050DC1

58

50–58

812

17

30

37

37

55

15

15

40

50

XTPR058DC1

65

55–65

882

18.5

34

37

45

55

15

15

40

50

XTPR063DC1

Notes
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.

1

Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor:
SF = 1.15 → Ir = 1 x In mot
SF = 1 → Ir = 0.9 x In mot

1
1

For manual motor protective circuit breaker switching capacity, see Page V5-T1-181.

1

2

1

Select manual motor protectors by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).

1
1
V5-T1-162

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Frame B

XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame B 1
Motor Protective Device with Thermal and Magnetic Trip

Rated
Uninterrupted
Current—
Iu (Amps)
0.16

FLA
Adjustment
Range/
Overload
Release—
Ir (Amps)

0.1–0.16

Short
Circuit
Release—
Irm (Amps)

1
1

Maximum Motor Ratings

2

Maximum hp Rating—P (hp)
Three-Phase

Rated Short-Circuit
Breaking Capacity (kA)

Manual Motor
Protector—
Screw Terminal
Catalog Number

480V/
277V

600V/
247V

240V

480/
277V

600/
347V

Line Side
Adapter 1
Catalog Number

3

1/2

1/2

65

65

50

XTPAXLSA

XTPRP16BC1

3

1/2

1/2

65

65

50

XTPAXLSA

XTPRP25BC1

200V

240V

2.2

3

0.25

0.16–0.25

3.4

3

0.4

0.25–0.4

5.6

3

3

1/2

1/2

65

65

50

XTPAXLSA

XTPRP40BC1

0.63

0.4–0.63

8.8

3

3

1/2

1/2

65

65

50

XTPAXLSA

XTPRP63BC1

1

0.63–1

14

3

3

1/2

1/2

65

65

50

XTPAXLSA

XTPR001BC1

1.6

1–1.6

22

3

3

3/4

3/4

65

65

50

XTPAXLSA

XTPR1P6BC1

2.5

1.6–2.5

35

1/2

1/2

1

1-1/2

65

65

50

XTPAXLSA

XTPR2P5BC1

4

2.5–4

56

3/4

1

2

3

65

65

50

XTPAXLSA

XTPR004BC1

6.3

4–6.3

88

1

1-1/2

3

5

65

65

50

XTPAXLSA

XTPR6P3BC1

10

6.3–11

140

3

3

7-1/2

10

65

65

50

XTPAXLSA

XTPR010BC1

12

8–12

168

3

3

7-1/2

—

65

65

—

XTPAXLSA

XTPR012BC1

16

10–16

224

3

5

10

—

42

42

—

XTPAXLSA

XTPR016BC1

20

16–20

280

5

5

—

—

18

18

—

XTPAXLSA

XTPR020BC1

25

20–25

350

5

7-1/2

15

—

18

18

—

XTPAXLSA

XTPR025BC1

32

25–32

448

7-1/2

10

25

—

18

18

—

XTPAXLSA

XTPR032BC1

1
1
1
1
1
1
1
1
1
1
1
1

Frame D

XTPR Manual Self-Protected Motor Starters—North American Ratings, UL 508 Type E—Frame D
Motor Protective Device with Thermal and Magnetic Trip

Rated
Uninterrupted
Current—
Iu (Amps)

FLA
Adjustment
Range/
Overload
Release—
Ir (Amps)

1

1
1

Short
Circuit
Release—
Irm (Amps)

Maximum Motor Ratings 2
Maximum hp Rating—P (hp)
Three-Phase
200V

240V

480V/
277V

600V/
247V

Rated Short-Circuit
Breaking Capacity (kA)
240V

480/
277V

600/
347V

Line Side
Adapter 1
Catalog Number

Manual Motor
Protector—
Screw Terminal
Catalog Number

16

10–16

224

3

5

10

10

65

65

25

XTPAXLSAD

XTPR016DC1

25

16–25

350

7-1/2

7-1/2

20

25

65

65

25

XTPAXLSAD

XTPR025DC1

32

25–32

448

10

10

25

30

65

65

25

XTPAXLSAD

XTPR032DC1

40

32–40

560

10

—

30

30

65

65

25

XTPAXLSAD

XTPR040DC1

50

40–50

700

—

15

30

—

65

65

—

XTPAXLSAD

XTPR050DC1

58

50–58

812

—

—

40

—

65

65

—

XTPAXLSAD

XTPR058DC1

65

55–65

882

—

—

40

—

65

65

—

XTPAXLSAD

XTPR063DC1

Notes
A UL 508 Type E self-protected manual combination starter (XTPR) consists of a manual motor protector (XTPR) and a UL Listed line side adapter (e.g., XTPAXLSA).
The Type E self-protected manual combination starter alone is a legitimate short-circuit protective device and disconnect means for the downstream motor,
while the contactor has been added to provide remote operation of the motor circuit. Conductor size for XTPAXLSA is 14–6 AWG, XTPAXLSAD is 8 AWG–1/0.
1
2
3

UL 508 Type E starters are assembled from a standard XTPR and a special incoming terminal line side adapter (XTPAXLSA or XTPAXLSAD).
Select manual motor protectors by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-163

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Accessories
Auxiliary Contacts
XTPAXSA_

Side-Mount Auxiliary Contacts
Contact
Configuration

1

1NO-1NC

Contact Sequence
1.13 1.21

L1 L2 L3

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTPAXSA11

5

XTPAXSA12

5

XTPAXSA21

XTPAXSA11

1
1

1.14 1.22

1NO-2NC

1

1.13 1.21 1.31

L1 L2 L3
XTPAXSA12

1

1.14 1.22 1.32

1

2NO-1NC

1.13 1.21 1.33

L1 L2 L3
XTPAXSA21

1

1.14 1.22 1.34

1

Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and
manual transformer protectors (XTPT) and can be combined with XTPAXSATR_ and
XTPAXFA_ trip indicating auxiliary contact.

1
1
1

XTPAXFA11

Front-Mount Auxiliary Contacts
Contact
Configuration

1

1NO-1NC

1

Contact Sequence
1.53 1.61

L1 L2 L3

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTPAXFA11

XTPAXFA11

1

1.54 1.62

1

Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual
transformer protectors (XTPT). 45 mm (XTPR…B and XTPB) or 55 mm (XTPR…D)
widths of manual motor protectors remain unchanged.

1

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
V5-T1-164

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

XTPAXSATR_

1.1

Side-Mount Trip Indicating Auxiliary Contacts
Contact
Configuration

Contact Sequence

2 x 1NO

“+” “ ”
4.43 4.13

1

Pkg.
Qty. 1

For Use
with…

2

XTPB, XTPR,
XTPM, XTPT

Catalog Number

1

XTPAXSATR20

1
1

4.44 4.14

On/Off

1

L1L2 L3
“+”
“ >”
Trip “+”

1
1

L1L2 L3
“+”
“ >”

1

2 x 1NC

“+” “ ”
4.31 4.21

2

XTPB, XTPR,
XTPM, XTPT

XTPAXSATR02

1
1

4.32 4.22

1

On/Off

1

L1L2 L3
“+”
“ >”
Trip “+”

1

L1L2 L3
“+”
“ >”

1
1

Can be fitted on the right side of manual motor protectors. Can be combined with
standard auxiliary contacts. Trip indication: A. General trip indication (overload) B.
Short-circuit trip. Local short-circuit indication by red indicator, manually resettable.

1
1

Early-Make Front-Mount Auxiliary Contacts
Contact
Configuration
XTPBXFAEM20

2NO

Contact Sequence
3.13 3.23

Pkg.
Qty. 1

For Use
with…

Catalog Number

5

XTPB

XTPBXFAEM20

1
1
1
1

3.14 3.24

XTPAXFAEM20

2NO

2

XTPR, XTPM,
XTPT

XTPAXFAEM20 2

1
1
1
1

For use with XTPB_, Frame B XTPR and XTPT. Can be fitted to the front of a manual
motor protector. 45 mm width of manual motor protector remains unchanged. For early
energization of undervoltage release, e.g., in emergency-stop circuits to EN 60204.

1

Notes
1 Orders must be placed in multiples of package quantity listed.
2 Not for use with rotary handle mechanism.

1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-165

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

XT IEC Power Control

Additional Accessories
XTPAXSR_

1
1
1

IEC Contactors and Starters

Contact Sequence
C1

1
1

Shunt Release

Undervoltage Release

XTPAXUVR_

Pkg.
Qty. 1

Screw Terminal
Catalog Number

Pkg.
Qty. 1

Screw Terminal
Catalog Number

2

XTPAXSR24V50H

2

XTPAXUVR24V50H

2

XTPAXSR48V50H

2

XTPAXUVR24V60H

2

XTPAXSR110V50H

2

XTPAXUVR48V50H

2

XTPAXSR120V60H

2

XTPAXUVR60V50H

2

XTPAXSR208V60H

2

XTPAXUVR110V50H

2

XTPAXSR220V50H

2

XTPAXUVR120V60H

2

XTPAXSR230V50H

2

XTPAXUVR208V60H

2

XTPAXUVR220V50H

2

XTPAXUVR230V50H

Contact Sequence
D1

U

2

XTPAXSR240V50H

2

XTPAXSR240V60H

2

XTPAXSR380V50H

2

XTPAXUVR240V50H

2

XTPAXSR400V50H

2

XTPAXUVR240V60H

2

XTPAXSR415V50H

2

XTPAXUVR380V50H

2

XTPAXSR440V60H

2

XTPAXUVR400V50H

1

2

XTPAXSR480V60H

2

XTPAXUVR415V50H

2

XTPAXSR24VDC

2

XTPAXUVR440V60H

1

2

XTPAXSR48VDC

2

XTPAXUVR480V60H

2

XTPAXSR60VDC

2

XTPAXUVR600V60H

1

2

XTPAXSR110VDC

2

XTPAXSR125VDC

2

XTPAXSR220VDC

2

XTPAXSR250VDC

Can be used to trip the manual motor
protector from a remote location. Can
be fitted on left side manual motor
protectors. Cannot be combined with
XTPAXSR. When combined with a circuit
breaker, it can be used as emergency-stop
device to IEC/EN 60204.

C2

1
1
1

1
1

Can be used to trip the manual motor
protector from a remote location. Can
be fitted on the left side of manual
motor protectors. Cannot be combined
with the XTPAXUVR. DC: Intermittent
operation 5 sec.

1
1
1
1

D2

XTPAXCL

Current Limiter 2

1

Description

1

To enhance the switching capacity of non-inherently
safe 10–25A manual motor protectors to 150 kA/440V

1

Contact
Sequence
L

Pkg.
Qty. 1

Catalog Number

1

XTPAXCL

T

1

The XTPAXCL enhances the switching capacity of the XT manual motor
protectors. It can be used with the XTPB, XTPR…BC1, XTPR…DC1 for
individual or group protections. The rated uninterrupted current is 63A for IEC
and 25A for UL/CSA. It can be mounted next to or behind the manual motor
protector. See Page V5-T1-181 for ratings when using the current limiter.

1
1

Notes
1 Orders must be placed in multiples of package quantity listed.
2 Max. rated operation voltage Ue = 690V, rated uninterrupted current I = 63A. Can be used for individual and
u
group protection. For group protection and in combination with the XTPR…D order additional XTPAXIT incoming
terminal if required. Mounting next to or behind the manual motor protector. 16–63A XTPR…D: 100 kA/400V, 10 kA/690V.

1
1
1
1
1
V5-T1-166

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

IP65 Rotary Handle Mechanism 1234
Enclosure
Rating

Description
XTPAXRHM_

1
Catalog Number

1

Complete Kits—Includes Handle, Shaft and Required Hardware
Rotary handle mechanism—black 6

IP65
NEMA 12
UL/CSA 4X

1

XTPAXRHMB

1

XTPAXRHMRY

Rotary handle mechanism—black—rotated 90° from vertical 6

1

XTPAXRHM90B

Rotary handle mechanism—red/yellow—rotated 90° from
vertical 7

1

XTPAXRHM90RY

10

XTPAXRHMSFT

Rotary handle mechanism—red/yellow 7

XTPAXRHMSFT

Pkg.
Qty. 5

1
1
1

Separate Parts
Shaft only—includes shaft to mount to XTPR, 175 mm length

—

1
1

XTPAXSW

Sealing Facility
Description
To prevent tampering with the overload release and the test function.
It can be sealed using industry standard sealing wire. For use with
XTPR manual motor protectors.

1

Pkg.
Qty. 5

Catalog Number

5

XTPAXSW

1
1
1

Three-Phase Commoning Links
For Use with…
MMP with no side-mounted
auxiliaries or voltage releases

Each MMP with one auxiliary
contact or trip-indicating auxiliary
contact fitted on the right

Each MMP with an auxiliary
contact and trip-indicating
auxiliary contact mounted on
the right or a voltage release
mounted on the left.

8

1

Qty.
MMP

Length of
Link (mm)

Unit
Width (mm)

Pkg.
Qty. 5

Catalog Number

2

90

45

10

XTPAXCLKA2

1

3

135

45

10

XTPAXCLKA3

1

4

180

45

10

XTPAXCLKA4

1

5

225

45

10

XTPAXCLKA5

1

2

99

45 + 9

10

XTPAXCLKB2

1

3

153

45 + 9

10

XTPAXCLKB3

1

4

207

45 + 9

10

XTPAXCLKB4

1

5

261

45 + 9

10

XTPAXCLKB5

1

2

108

45 + 18

10

XTPAXCLKC2

1
1
1

For parallel power feed to several manual motor protectors on terminals
1, 3 and 5.

1

Notes
1 Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of 100–240 mm. Carrier
with extension shaft included.
2 With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4–8 mm hasp. Can be locked in the
OFF position, if required.
3 Rotary handle mechanisms ship with door interlock disabled. See instruction publication with product for how to
enable door interlock.
4 Not for use with XTPAXFAEM20 early-make front-mount auxiliary contact.
5 Orders must be placed in multiples of package quantity listed.
6 For use on main switches to IEC/EN 60204.
7 For use on main switches with emergency-stop function to IEC/EN 60204.
8 Protected against accidental contact. Frame B short-circuit proof Ue = 690V, I = 63A. Frame B links can be combined by
u
rotating mounting.

1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-167

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

XTPAXUTS

1
1
1
1

XTPAXIT

1

IEC Contactors and Starters
XT IEC Power Control

Shroud for Unused Terminals of Three-Phase Commoning Links
For Use with…

Description

Frame B
XTPR

To cover unused terminals on three-phase
commoning link. Protected against direct
contact.

Pkg.
Qty. 1

Catalog Number

20

XTPAXUTS

Incoming Terminals for Three-Phase
Commoning Link 2
For Use with…

Pkg.
Qty. 1

Catalog Number

Frame B XTPR, XTPB

5

XTPAXIT

Pkg.
Qty. 1

Catalog Number

1
1

Line-Side Adapter 3

1

For Use with…

1

XTPAXLSA

Frame B XTPR to create a
UL 508 Type E/F manual
combination starter

5

XTPAXLSA

XTPAXLSAD

Frame D XTPR to create a
UL 508 Type E/F manual
combination starter

1

XTPAXLSAD 4

1
1
1
1
1
1

Combination Connection Kits

1

Non-Reversing Starters

1

For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPR…B + XTCE…B

Mechanical connection element for XTPR…B and contactor

1

XTPAXTPCB

Main current wiring between XTPR…B and contactor in toolless plug connection

1

1

XTPAXTPCB

1

Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables
up to 2.5 mm2 external diameter or four cables up to 3.5 mm2 external diameter.

1
1

XTPAXTPC_

1

XTPR…B + XTCE…C

DIN rail adapter plate
Main current wiring between XTPR and contactor

1

XTPAXTPCC

XTPR…D + XTCE…D

DIN rail adapter plate
Main current wiring between XTPR and contactor

1

XTPAXTPCD

1
1
Notes
1 Orders must be placed in multiples of package quantity listed.
2 For three-phase commoning link, protected against accidental contact, U = 690V, I = 63A;
e
u
For conductor cross-sections: 2.5–25 mm2 stranded; 2.5–16 mm2 flexible with ferrules, AWG 14-6.
3 XTPAXLSA is for three-phase commoning link, finger and back-of-hand proof,
Ue = 690V, Iu = 60A for conductor cross sections: 2.5–25 mm2 stranded,
2.5–16 mm2 flexible with ferrule, AWG 14-6.
4 XTPAXLSAD cannot be combined with three-phase commoning links. Conductor size 8 AWG–1/0.

1
1
1
1
1
V5-T1-168

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Reversing Starters

XTPAXTPCRB

1

For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPR…B + XTCE…B01_

Mechanical connection element for XTPR…B and contactor

1

XTPAXTPCRB

Reversing starter main current wiring in toolless plug connection

1

Control cables for electrical interlocking in toolless plug connection:
– K1M: A1–K2M: 21
– K1M: 21–K2M: A1
– K1M: A2–K2M: A2

1

Cable guidance

1

1
1
1

Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables
up to 2.5 mm2 external diameter or four cables up to 3.5 mm2 external diameter.
XTPAXTPCRC

XTPR…B + XTCE…C

1

1

DIN rail adapter plate

1

Reversing starter main current wiring

1

XTPAXTPCRC

1
1
1
1

Star-Delta Starter Sets

XTPAXSDSB

1

For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPR…B + XTCE…B

DIN rail adapter plate

1

XTPAXSDSB

Main current wiring between XTPR…B and contactor

1

Electrical interlock between delta and star contactor

1

1
1
1

Use as contactor auxiliary switch XTCEXFAT_

1
XTPAXSDSC

XTPR…B + XTCE…C

DIN rail adapter plate

1

Main current wiring between XTPR…B and contactor

1

XTPAXSDSC

1
1
1
1
1

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-169

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

XTPAXECM_

1
1

IEC Contactors and Starters
XT IEC Power Control

Electrical Connection Module
For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPR…B + XTCE…C

Main current wiring between XTPR…B and contactor

5

XTPAXECMC

XTPR…D + XTCE…D

Main current wiring between XTPR…D and contactor

5

XTPAXECMD

1

DIN Rail Adapter Plates

1

For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPAXTPCB
XTPAXTPCRB

45 mm wide adapter plate with one DIN rail

4

XTPAXTPCPB

XTPAXECMD
XTPR…D + XTCE…C
XTPR…D + XTCE…D

55 mm wide adapter plate with two DIN rails

4

XTPAXTPCPD

1

XTPAXTPCPB

Connection element for side-by-side positioning of further plates

1
1
1

XTPAXTPCPD

1

Connection cams for further plates
For use with reversing and star-delta starters

1
1

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-170

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Pushbutton MMP Enclosures

1

Insulated Enclosures for Surface Mounting of XTPB Pushbutton
Motor-Protective Circuit Breakers—Global Usage 1
Degree of
Protection

For Use
with…

IP40
NEMA 1

XTPB MMP only or with:
XTPAXFA_, XTPBXFAEM20,
XTPAXSA_, XTPAXUVR_,
XTPAXSR_

IP65
NEMA
3R, 4X, 12, 13

1

Description

Catalog Number

—

XTPBXENCS40

1
1
1

With actuation membrane.

XTPBXENCS65

1
1

IP65
NEMA
3R, 4X, 12, 13

XTPB MMP only or with:
XTPAXFA_, XTPAXUVR_,
XTPAXSR_, XTPAXCL

Lockable in OFF position.

XTPBXENCSLO65

IP65
NEMA
3R, 4X, 12, 13

XTPB MMP only or with:
XTPAXFA_, XTPBXFAEM20,
XTPAXUVR_, XTPAXSR_,
XTPAXCL

Lockable in OFF position in combination with XTPBXFAEM20
early-make front-mount auxiliary contact

XTPBXENCSLE65

With emergency-stop (e-stop) pushbutton actuator, red-yellow

XTPBXENCSES65

With emergency-stop (e-stop) pushbutton actuator, red-yellow
key release

XTPBXENCSEK65

IP65
NEMA
3R, 4X, 12, 13

1
1
1
1

IP65
NEMA
3R, 4X, 12, 13

1
1

Insulated Enclosures for Surface Mounting of XTPB Pushbutton
Manual Motor Protectors—North American Usage 23
Degree of
Protection

For Use
with…

IP41
NEMA 1

XTPB MMP only or with:
XTPAXFA_, XTPBXFAEM20,
XTPAXSA_, XTPAXUVR_,
XTPAXSR_

IP65
NEMA
3R, 4X, 12, 13

1

Description

Catalog Number

—

XTPBXENAS41

With actuating diaphragm

XTPBXENAS65

1
1

XTPB MMP only or with:
XTPAXFA_, XTPAXUVR_,
XTPAXSR_, XTPAXCL

Lockable in OFF position

XTPBXENASLO65

IP65
NEMA
3R, 4X, 12, 13

XTPB MMP only or with:
XTPAXFA_, XTPBXFAEM20,
XTPAXUVR_, XTPAXSR_,
XTPAXCL

Lockable in OFF position in combination with XTPBXFAEM20
early-make front-mount auxiliary contact

XTPBXENASLE65

With emergency-stop (e-stop) pushbutton actuator, red-yellow

XTPBXENASES65

With emergency-stop (e-stop) pushbutton actuator, red-yellow
key release

XTPBXENASEK65

IP65
NEMA
3R, 4X, 12, 13

1
1

IP65
NEMA
3R, 4X, 12, 13

IP65
NEMA
3R, 4X, 12, 13

1

1
1
1
1
1
1

Notes
1 Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom.
2 Built-in terminal for PE(N).
3 North American enclosures come with conduit adapters for use with 1/2 in NPT.

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-171

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

Insulated Enclosures for Surface Mounting of XTPB Pushbutton
Manual Motor Protectors—North American Usage 1

1

Degree of
Protection

For Use
with…

1

Front IP40
NEMA 1

XTPB MMP only or with:
XTPAXFA_, XTPBXFAEM20,
XTPAXSA_, XTPAXUVR_,
XTPAXSR_

1
Front IP65
NEMA
3R, 4X, 12, 13

1

Description

Catalog Number

—

XTPBXENCF40

With actuating diaphragm

XTPBXENCF55

1
1
1
1

Front IP65
NEMA
3R, 4X, 12, 13

XTPB MMP only or with:
XTPAXFA_, XTPAXUVR_,
XTPAXSR_, XTPAXCL

Lockable in OFF position

XTPBXENCFLO55

Front IP65
NEMA
3R, 4X, 12, 13

XTPB MMP only or with:
XTPAXFA_, XTPBXFAEM20,
XTPAXUVR_, XTPAXSR_,
XTPAXCL

Lockable in OFF position in combination with XTPBXFAEM20
early-make front-mount auxiliary contact

XTPBXENCFLE55

With emergency-stop (e-stop) pushbutton actuator, red-yellow

XTPBXENCFES55

With emergency-stop (e-stop) pushbutton actuator, red-yellow
key release

XTPBXENCFEK55

Front IP65
NEMA
3R, 4X, 12, 13

1

Front IP65
NEMA
3R, 4X, 12, 13

1
1

Note
1 Integrated terminal for PE(N) connection.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-172

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Rotary MMP Enclosures

1
1

Insulated Enclosures for Surface Mounting of Frame B (0.1–32A)
XTPR Motor-Protective Circuit Breakers—Global Usage
Degree of
Protection

For Use
with…

IP41 with vertical
mounting

Frame B XTPR only or with:
XTPAXFA_, XTPAXSA_,
XTPAXSATR_, XTPAXUVR_,
XTPAXSR_, XTPAXCL

Description

Catalog Number

Cover with aperture dimensioned to accommodate front of
MMP. IP40, when mounted turned through 90° to left/right

XTPAXENCS41 1

1
1
1

IP65

With black/grey rotary handle

XTPAXENCS65B 1

IP65

With red/yellow rotary handle for use as emergency-stop
switches to IEC/EN 60204

XTPAXENCS65RY 1

1
1
1

IP40

Frame B XTPR only or with:
XTPAXSA_, XTPAXUVR_,
XTPAXSR_, XTPAXCL

Cover with aperture dimensioned to accommodate front of MMP

XTPAXENCS40 2

IP55

Frame B XTPR only or with:
XTPAXFA_, XTPAXSA_,
XTPAXUVR_, XTPAXSR_,
XTPAXCL

With black/gray rotary handle

XTPAXENCS55B 2

1

With red/yellow rotary handle for use as emergency-stop
switches to IEC/EN 60204

XTPAXENCS55RY 2

1

1
1

IP55

1
1

Insulated Enclosures for Surface Mounting of Frame B (0.1–32A)
XTPR Rotary Manual Motor Protectors—North American Usage 3
Degree of
Protection

For Use
with…

IP55
NEMA 1, 12, 3R

Frame B XTPR only or with:
XTPAXSA_ and XTPAXFA_,
XTPAXUVR_ and XTPAXFA_,
XTPAXSR_ and XTPAXFA_,
XTPAXCL

1

Description

Catalog Number

With black/gray rotary handle

XTPAXENAS55B

1

With red/yellow rotary handle for use as emergency-stop
switch to VDE 0113

XTPAXENAS55RY

1
1

Insulated Enclosures for Surface Mounting of Frame B XTPR (0.1–32A) Rotary Motor-Protective Circuit
Breakers with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact—Global Usage

1

Degree of
Protection

For Use
with…

1

IP65

Frame B XTPR and XTPAXFAEM20
only or with: XTPAXFA_,
XTPAXSA_, XTPAXSATR_,
XTPAXUVR_, XTPAXSR_,
XTPAXCL

IP65
IP55
IP55

Frame B XTPR and XTPAXFAEM20
only or with: XTPAXFA_,
XTPAXUVR_, XTPAXSR_,
XTPAXCL

Description

Catalog Number

With black/gray rotary handle

XTPAXENCSEM65B

1

With red/yellow rotary handle for use as emergency-stop
switches to IEC/EN 60204

XTPAXENCSEM65RY

1

With black/gray rotary handle

XTPAXENCSEM55B

1

With red/yellow rotary handle for use as emergency-stop
switches to IEC/EN 60204

XTPAXENCSEM55RY

1
1

Notes
1 M25 metric cable entry knock-out, top and bottom. Cable push-through membrane, top and bottom, in the back plate and as a control line entry.
Includes N and PE terminals.
2 Integrated terminal for PE(N) connection, two M25 cable entry knockouts at the top and bottom.
3 Built-in N and PE terminal, lower part without knockouts.

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-173

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

Insulated Enclosures for Surface Mounting of Frame B XTPR (0.1–32A) Rotary Manual Motor Protectors
with XTPAXFAEM20 Early-Make Front-Mount Auxiliary Contact—North American Usage 1

1

Degree of
Protection

For Use
with…

1

IP55
NEMA 1, 12, 3R

Frame B XTPR only or with:
XTPAXSA_, XTPAXUVR_,
XTPAXCL

1
1

Description

Catalog Number

With black/grey rotary handle

XTPAXENASEM55B

With red/yellow rotary handle for use as emergency-stop
switch to VDE 0113

XTPAXENASEM55RY

Insulated Enclosures for Flush Mounting of Frame B (0.1–32A)
XTPR Rotary Manual Motor Protectors—Global Usage 2

1
1

Degree of
Protection

For Use
with…

Front IP40

Front IP55

1
1
1

Description

Catalog Number

Frame B XTPR only or with:
XTPAXSA_, XTPAXUVR_,
XTPAXSR_, XTPAXCL

Cover with aperture dimensioned to accommodate front of MMP

XTPAXENCF40

Frame B XTPR only or with:
XTPAXSA_, XTPAXUVR_,
XTPAXSR_, XTPAXFA_,
XTPAXCL

With black/gray rotary handle

XTPAXENCF55B

With red/yellow rotary handle for use as emergency-stop
switches to IEC/EN 60204

XTPAXENCF55RY

1
1

Insulated Enclosures for Surface Mounting of Frame D (10–65A)
Rotary Motor-Protective Circuit Breakers

1
1
1

Degree of
Protection

For Use
with…

IP65
NEMA 1, 12,
3R, 4X

Frame D XTPR only or with:
XTPAXFA_, XTPAXFAEM20,
XTPAXSA_, XTPAXSATR_,
XTPAXUVR_, XTPAXSR_,
XTPAXCL

IP65
NEMA 1, 12,
3R, 4X

1
1

Description

Catalog Number

With black/gray rotary handle

XTPAXENCSD65B

With red/yellow rotary handle for use as emergency-stop
switches to IEC/EN 60204

XTPAXENCSD65RY

Notes
1 Built-in N and PE terminal, lower part without knockouts.
2 Integrated terminal for PE(N) connection.

1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-174

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

MMP Enclosure Accessories
XTPAXPL_

1

XTPR Manual Motor Protector Enclosure Padlock Attachment
For Use
with…

Pkg.
Qty. 1

Catalog Number

3

XTPAXPL1 2

XTPAXENCSD65B, XTPAXENCSD65RY

1

XTPAXPL2

2

XTPAXENCF55B, XTPAXENCF55RY

3

XTPAXPL3 3

Description

XTPAXENCS65B, XTPAXENCS65RY,
XTPAXENCSEM65B, XTPAXENCSEM65RY,
XTPAXENCS55B, XTPAXENCS55RY,
XTPAXENCSEM55B, XTPAXENCSEM55RY

Padlocking feature. Up to three padlocks with 3–6 mm hasp thickness.
For use as main switch to IEC/EN 60204

1
1
1
1
1

XTPAXNT

Neutral Terminal for Use with XTPB and Frame B XTPR Flush-Mount Enclosures
For Use
with…
XTPBXENCF40, XTPBXENCF55, XTPAXENCF40,
XTPAXENCF55B, XTPAXENCF55RY

XTPAXIL_

1

Description

Pkg.
Qty. 1

Catalog Number

For connection of a fifth conductor

20

XTPAXNT

1
1

Indicating Lights with Neon Bulb
Color

Description—
Indicating Light

White

110–230V

10

XTPAXILWB

230–400V

10

XTPAXILWN

Green

Red

1

Pkg.
Qty. 1

Catalog Number

415–500V

10

XTPAXILWC

110–230V

10

XTPAXILGB

230–400V

10

XTPAXILGN

415–500V

10

XTPAXILGC

110–230V

10

XTPAXILRB

230–400V

10

XTPAXILRN

1
1
1
1
1
1

For use with XTPR and XTPB enclosures.

1

Lights do not carry individual IP or NEMA rating. All enclosure ratings remain
valid when using indicating lights.

1

Notes
1 Orders must be placed in multiples of package quantity listed.
2 Lockable in the 0-position of the XTPR manual motor protector.
3 Lockable in the OFF position of the Frame B XTPR manual motor protector.

1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-175

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Technical Data and Specifications
XT Manual Motor Protectors
XTPBP16B–
XTPB025B

XTPRP16B–
XTPR032B

XTPR016D–
XTPR063D

Standards

IEC/EN 60947,
VDE 0660, UL 508,
CSA C22.2 No. 14

IEC/EN 60947,
VDE 0660, UL 508,
CSA C22.2 No. 14

IEC/EN 60947,
VDE 0660, UL 508,
CSA C22.2 No. 14

Climatic proofing

1

1

1

Description
General

Ambient temperature, °C
Storage

–25/80

–25/80

–25/70

Open

–25/55

–25/55

–25/55

Enclosed

–25/40

Mounting position

90

–25/40
90

90

–25/40
90

90

90

90

90

1
1
1

Direction of incoming supply

As required

As required

As required

Device

IP20

IP20

IP20

Terminals

IP00

IP00

IP00

Degree of protection

1

Protection against direct contact

Finger and
back-of-hand proof

Finger and
back-of-hand proof

Finger and
back-of-hand proof

1

Shock resistance half-sinusoidal shock
10 ms to IEC 60068-2-27 (g)

25

25

15

1

Altitude (m), maximum

2000

2000

2000

Terminal capacity

1

Solid (mm2)

1 x (1–6)
2 x (1–6)

1 x (1–6)
2 x (1–6)

1 x (1–50)
2 x (1–35)

1

Flexible with ferrule to DIN 46228, (mm2)

1 x (1–6)
2 x (1–6)

1 x (1–6)
2 x (1–6)

1 x (1–35)
2 x (1–35)

Solid or stranded (AWG)

18–10

18–10

14–2

1

Terminal screw tightening torque

1

Main cable, Nm

1.7

1.

3

Main cable, lb-in

15.0

15.0

26.6

1

Control circuit cable, Nm

1

1

1

Control circuit cable, lb-in

8.9

8.9

8.9
6000

1

Main Contacts
Rated impulse withstand voltage (Uimp), Vac

6000

6000

1

Overvoltage category/pollution degree

III/3

III/3

III/3

Rated operational voltage (Ue), Vac

690

690

690

1

Rated uninterrupted current = rated operational
current (Iu = Ie) in amperes

25 or current setting of
the overcurrent release

25 or current setting of
the overcurrent release

25 or current setting of
the overcurrent release

1

Rated frequency, Hz

40–60

40–60

40–60

Current heat loss (three-pole at operating temperature), W

6

6

22

1

Lifespan, mechanical (ops)

50,000

100,000

30,000

Lifespan, electrical (AC-3 at 400V) (ops)

50,000

100,000

30,000

1

Maximum operating frequency, operations/hr

25

40

40

1
1
1
1
1

Short-circuit rating
AC

See Page V5-T1-181

See Page V5-T1-181

See Page V5-T1-181

DC (kA)

60

60 (up to XTPR016B)
40 (XTPR020B–XTPR032B)

60

AC-3 (up to 690V) in amperes

25

32

65

DC-5 (up to 250V) in amperes

25

25 (3 contacts in series)

63 (3 contacts in series)

Motor switching capacity

Note
1 Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60068-2-30.

V5-T1-176

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

XT Manual Motor Protectors, continued
XTPBP16B–
XTPB025B

XTPRP16B–
XTPR032B

XTPR016D–
XTPR063D

Overload release setting range (x Iu)

0.6–1.0

0.6–1.0

0.6–1.0

Fixed short-circuit release (x Iu)

14

14

14

Description

1
1

Releases

Short-circuit release tolerance

± 20%

± 20%

± 20%

Phase-failure sensitivity

IEC/EN 60947-1-1,
VDE 0660 Part 102

IEC/EN 60947-1-1,
VDE 0660 Part 102

IEC/EN 60947-1-1,
VDE 0660 Part 102

1
1
1

Temperature compensation
to IEC/EN 60947, VDE 0660, °C

–5/40

–5/40

–5/40

operating range, °C

–25/55

–25/55

–25/55

<0.25

<0.25

<0.25

Temperature compensation residual error for T >20°C, %/K

1
1
1

Auxiliary Contacts
Description

XTPAXSA_ _

XTPAXFA_ _

XTPA(B)XFAEM_ _

XTPAXSATR_ _

Rated impulse withstand voltage, Uimp (Vac)

6000

4000

4000

6000

Overvoltage category/pollution degree

III/3

III/3

III/3

III/3

Ue (Vac)

500

440

440

500

Ue (Vdc)

250

250

250

250

690

690

690

690

1
1
1

Rated operational voltage

Safe isolation to VDE 0106 Part 101 and
Part 101/A1 between auxiliary contacts
and main contacts (Vac)

1
1
1

Rated operational current
AC-15
220–240 V, Ie (A)

3.5

1

1

3.5

380–415 V, Ie (A)

2

—

—

2

440–500 V, Ie (A)

1

—

—

1

1
1
1

DC-13 L/R <100 ms
24 V, Ie (A)

2

2

2

2

60 V, Ie (A)

1.5

—

—

1.5

110 V, Ie (A)

1

—

—

1

220 V, Ie (A)

0.25

—

—

0.25

Mechanical, operations (x 106)

0.1

0.1

0.1

0.01

Electrical, operations (x 106)

0.05

0.1

0.1

0.005

1

Contact reliability (at Ue = 24 Vdc, Umin–17V,
Imin = 5.4 mA, fault probability

<10–8 <1 fault
at 1 x 108 operations

<10–8 <1 fault
at 1 x 108 operations

<10–8 <1 fault
at 1 x 108 operations

<10–8 <1 fault
at 1 x 108 operations

1

Positively driven contacts to ZH 1/457

Yes

—

—

—

1
1
1

Lifespan

1

Short-Circuit Rating without Welding
Fuseless

FAZ-B4/1-HI

—

—

FAZ-B4/1-HI

Fuse (A gG/gL)

10

10

10

10

Solid or flexible conductor with ferrule (mm2)

0.75–2.5

0.75–1.5

0.75–1.5

0.75–2.5

Solid or stranded (AWG)

18–14

18–16

18–16

18–14

1
1

Terminal Capacity

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-177

1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Undervoltage Release
Description

XTPAXUVR_

Cross-Section

Min. Cross-Section Protected

Solid or flexible conductor with ferrule (mm2)

380-415V, 50 Hz, Cu mm2
4
2.5
1.5
1

Solid or stranded (AWG)

1 x (0.75–2.5)
2 x (0.75–2.5)

Device
Type
0.75
XTPRP16BC1

1 x (18–14)
2 x (18–14)

XTPR6P3BC1
XTPR010BC1
XTPR016BC1
XTPR020BC1
XTPR025BC1
XTPR016DC1
XTPR025DC1
XTPR032DC1
XTPR040DC1
XTPR050DC1
XTPR058DC1
XTPR063DC1

Main Contact
Rated operational voltage, Ue (Vac)

42–480

Rated operational voltage, Ue (Vdc)

24–250

Pickup voltage, x Us

0.85–1.1

1

Dropout voltage, x Us

0.7–0.35

1

Pickup AC (VA)

5

Sealing AC (VA)

3

1

Protection of PVC Insulated Cables Against Thermal
Overload at Short-Circuit

...

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

Power Consumption

1
1
1
1
1

Current Limiter
Description

XTPAXCL

Rated impulse withstand voltage (Uimp), Vac

6000

Overvoltage category/pollution degree

III/3

Rated operational voltage, Ue (Vac)

690

Rated interrupted current = Rated operational current (lu = le) in amperes

63

The chart above indicates which minimum cable cross-sections
are protected by XTPR motor protective circuit breakers up to
their rated conditional short-circuit current I q.

1
1
1
1
1

XTPB, XTPR Single- and Two-Pole Circuits with DC
and AC Current
1

3 5

I> I> I>

2 4 6

1

3 5

I> I> I>

2 4 6

Shunt Release
Description

XTPAXSR __

Cross-Section
Solid or flexible conductor with ferrule (mm2)

1 x (0.75–2.5)
2 x (0.75–2.5)

Solid or stranded (AWG)

1 x (18–14)
2 x (18–14)

Main Contact

1

Rated operational voltage, Ue (Vac)

24–250

1

Rated operational voltage, Ue (Vdc)
AC operating range, x Us

0.7–1.1

1

DC operating range, x Us (intermittent operation 5s)

0.7–1.1

Power Consumption

42–480

1

Pickup AC (VA)

5

Sealing AC (VA)

3

1

Pickup DC (VA)

3

Sealing DC (VA)

3

1
1
1
1
1
1
1
V5-T1-178

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XT IEC Power Control

Wiring Diagrams

1

Fuseless Installation with XTPR
Backup Protection Diagram—XTPR…B
100

30
20
16
10
6
0.16...

100

Back-up
protection
range
with XTPAXCL

Rated
short-circuit
breaking
capacity
range
XTPR…D

1

XTPR...D + XTPAXCL
50
30
20
16
10

Inherently
short-circuit-proof

Rated
short-circuit
breaking
capacity
range
XTPR…B

50

XTPR…D
415 Vac
cn
cc
Inherently short-circuit proof
cc rms [kA]

XTPR...B
Inherently
short-circuit-proof

XTPR…B + XTPAXCL

Back-up
protection
range
with XTPAXCL

1

Backup Protection Diagram—XTPR…D

XTPR…B

XTPR…B
415 Vac
cn
cc
Inherently short-circuit proof
cc rms [kA]

1

Rated
Current
n [A]

1

XTPR…D

1
1

6
16... 25

1016 20 25
Rated
Current
n [A]

32

40

1

50 63
Rated
Current
n [A]

1
1

Time/Current Curves

1

Characteristics

Under normal operating
conditions, all three-poles of
the device must be loaded.
The three main conducting
paths must be connected in
series in order to protect
single-phase or DC loads.
With three-pole loading, the
maximum deviation in the
tripping time for 3 times the
setting current and upwards
is ±20% and thus in
accordance with DIN VDE
0165.

Time/current characteristics,
current limiting characteristics
and I2t characteristics are
available on request.

Minutes
Seconds

2h
20
10
5

1

XTPB, XTPR Frame B

1

2
1
40
20
10
5

1
1
XTPT

2

1

1

Milli-seconds

The characteristics apply to
the cold state. At operating
temperature, the tripping
times of the thermal releases
are reduced to approximately
25%.

The characteristics of the
electromagnetic overcurrent
releases apply to frequencies
of 50/60 Hz. Appropriate
correction factors must be
used for lower frequencies up
to 16-2/3 Hz, for higher
frequencies up to 400 Hz and
for DC.

1

XTPB, XTPR Frame B

200

1

50

1

20

1

5
2
1.5 2
6 8 10 15 20
3 4
x Rated Operational Current

30

1

XTPR Frame D
Minutes

The tripping characteristic of
the inverse-time delayed
overload releases (thermal
overload releases or “a”
releases) for DC and AC with
a frequency of 0 to 400 Hz
also apply to the time/current
characteristic.

The tripping characteristics
for the instantaneous,
electromagnetic overcurrent
releases (short-circuit
releases or “n” releases) are
based on the rated current In,
which is also the maximum
value of the setting range for
circuit breakers with
adjustable overload releases.
If the current is set to a lower
value, the tripping current of
the “n” release is increased
by a corresponding factor.

Seconds

The time/current
characteristic, the current
limiting characteristics and
the I2t characteristics were
determined in accordance
with DIN VDE 0660 and IEC
60 947.

MMP Tripping Characteristics

2h
20
10
5

1
XTPR Frame D

1

2
1
40
20
10
5

1

2

1

1

1

Milli-seconds

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters

1

200

20

1

5

1

50

2
1.5 2
6 8 10 15 20
3 4
x Rated Operational Current

Volume 5—Motor Control and Protection

CA08100006E—August 2012

1

30

www.eaton.com

V5-T1-179

XTPR Frame D
32 A
25 A
20 A
16 A
10 A/12 A
6.3 A

10 XTPB
8 XTPR Frame B
^
ID
6 XTPM
[kA]
4
3

4.0 A

2

1

1
0.8
0.6

1
1
1

0.4
0.3

1.6 A

0.2

1A

0.63 A

0.04
0.03

1
1

Ue = 400 V
1 1.5 2 3 4

1
1

10

5

104

103

Ue = 400 V
0.25 A

6 8 10 15 20 3040 60 80100
cc rms [kA]

102
1

10

XTPR Frame D
100

XTPR Frame D

^

ID
[kA]

cc

1
2•

1

63/58 A
50/40/32 A
25 A
16 A

1
1

10

1
1
1
1

Ue = 400 V
1

63/58 A
50/40/32 A
25 A
16 A

0.4 A

0.02
0.015
0.01

XTPR Frame D

2.5 A

0.1
0.08
0.06

1

1

i dt
[A2 s]

•

1

106
2

e

XTPB, XTPR Frame B

cc

1

MMP Let-Through Tripping Characteristics

alf
-w
av

1

XT IEC Power Control

1s
th

1

IEC Contactors and Starters

2

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

1

10

100
cc rms[kA]

1
1
1
1
1
1
1
1
V5-T1-180

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

100
cc rms[kA]

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Manual Motor Protector Short-Circuit Ratings

1

Rated uninterrupted current Iu = Rated operational current Ie.
Rated conditional short-circuit current Iq —IEC/EN 60947-4-1.
Rated ultimate short-circuit breaking capacity Icu — IEC/EN 60947-2.
Rated operational short-circuit breaking capacity Ics — IEC/EN 60947-2.

1
1
1

Global Use, IEC/EN 60947—XTPB with Classification Type “1” and Type “2”
230V

400V

440V

500V

690V

Iu

Iq

Icu

Ics

Fuse 12

Iq

Icu

Ics

Fuse 12

Iq

Icu

Ics

Fuse 12

Iq

Icu

Ics

Fuse 12

Iq

Icu

Ics

Fuse 12

A

kA

kA

kA

A

kA

kA

kA

A

kA

kA

kA

A

kA

kA

kA

A

kA

kA

kA

A

0.16–1

50

50

50

50

50

50

50

50

50

50

50

50

—

—

—

—

—

—

—

—

1.6

50

50

50

50

50

50

50

50

50

50

50

50

—

—

—

—

—

—

—

—

2.5

50

50

50

50

50

50

50

50

50

50

50

50

—

—

—

—

—

—

—

—

4

50

50

50

50

50

50

50

50

50

50

50

50

—

—

—

—

—

—

—

—

6.3

50

50

50

50

50

50

50

50

50

50

50

50

—

—

—

—

—

—

—

—

10

50

50

50

50

50

50

50

50

42

42

10

50

—

—

—

—

—

—

—

—

12

50

50

10

50

50

50

10

50

15

15

10

50

—

—

—

—

—

—

—

—

16

50

50

10

50

50

50

10

50

15

15

10

50

—

—

—

—

—

—

—

—

20

50

50

10

50

50

50

10

50

10

10

10

50

—

—

—

—

—

—

—

—

25

50

50

10

50

50

50

10

50

10

10

10

50

—

—

—

—

—

—

—

—

400V
Icu

Fuse 12

Ics

Iq

440V
Icu

Fuse 12

Ics

Iq

500V
Icu

Ics

Fuse 12

Iq

690V
Icu

Ics

Fuse 12

Iq

Icu

Ics

Fuse 12

A

kA

kA

kA

A

N

3

3

3

N

Iu

Iq

A

kA

kA

kA

A

kA

kA

kA

A

kA

kA

kA

A

kA

kA

kA

0.16–1

150 3

150 3

150 3

N

150 3

150 3

150 3

N

3

3

3

N

3

3

3

1.6

150 3

150 3

150 3

N

150 3

150 3

150 3

N

3

3

3

N

3

3

3

N

3

3

3

N

2.5

150 3

150 3

150 3

N

150 3

150 3

150 3

N

3

3

3

N

3

3

3

N

5

5

5

50

4

150 3

150 3

150 3

N

150 3

150 3

150 3

N

3

3

3

N

3

3

3

N

3

3

3

50

3

3

3

3

3

3

3

3

6.3

150

N

150

N

3

N

42

42

6

50

3

3

2

50

10

150 3

150 3

150 3

N

150 3

150 3

150 3

N

42

42

10

50

42

42

6

50

3

3

2

50

12

50

50

10

50

50

50

10

50

15

15

10

50

15

15

6

50

3

3

2

50

16

50

50

10

50

50

50

10

50

15

15

10

50

15

15

6

50

3

3

2

50

20

50

50

10

50

50

50

10

50

15

15

10

50

6

6

6

50

3

3

2

50

25

50

50

10

50

50

50

10

50

10

10

10

50

6

6

6

50

3

3

2

50

32

50

50

10

50

50

50

10

50

10

10

10

50

6

6

6

50

3

3

2

50

150

150

150

150

1
1
1
1
1
1
1
1

Global Use, IEC/EN 60947—XTPR…BC1 with Classification Type “1” and Type “2”
230V

1

1
1
1
1
1
1
1
1
1

Notes
1 N = Not required.
2 XTPR…BC1, XTPT, XTPM—Required back-up fuse if the short-circuit current exceeds the rated conditional
short-circuit current (Icc > Iq); XTPB, XTPR…DC1—Fuse (A gG/gL) for enhancing the switching capacity of the
motor protective circuit breaker to 100 kA.
3 No upstream protective device required, as it is the auto-protected range (100/150 kA—Frame B, 150 kA—Frame D).

1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-181

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Global Use, IEC/EN 60947—XTPR…DC1 with Classification Type “1” and Type “2”
230V
Iu

Iq

400V
Icu

Ics

Fuse 12

Iq

440V
Icu

Ics

Fuse 12

Iq

500V
Icu

Ics

Fuse 12

Iq

690V
Icu

Ics
kA

Fuse 12

Iq

Icu

Ics

Fuse 12

A

kA

kA

kA

A

kA

kA

kA

A

kA

kA

kA

A

kA

kA

A

kA

kA

kA

A

16

150 3

150 3

25

N

150 3

150 3

25

N

45

45

25

100

15

15

100

8

8

2.5

100

25

150 3

150 3

25

N

150 3

150 3

25

N

45

45

25

100

15

15

100

8

8

2.5

100

32

50

50

25

100

50

50

25

100

45

45

25

100

15

15

100

5

5

2.5

100

1

40

50

50

25

100

50

50

25

100

45

45

25

100

15

15

100

5

5

2.5

100

50

50

50

25

100

50

50

25

100

45

45

25

100

15

15

100

5

5

2.5

100

1

58

50

50

25

160

50

50

25

160

45

45

25

160

15

15

160

5

5

2.5

160

63

50

50

25

160

50

50

25

160

45

45

25

160

15

15

160

5

5

2.5

160

1
1

1
1

Ratings for Group Motor Applications

1

UL 508/CSA C22.2 No. 14—XTPB—Frame B, Manual Motor Protector with Thermal and Magnetic Trip

1
1

FLA
Adjustment
Range/Overload
Release—
Ir (Amps)

Short
Circuit
Release—
Irm (Amps)

Maximum Protective Device for UL/CSA Group Protection

Catalog Number

Rated
Uninterrupted
Current—
Iu (Amps)

1

XTPBP16BC1

0.16

0.1–0.16

2.2

50

—

600

—

600

—

XTPBP25BC1

0.25

0.16–0.25

3.5

50

—

600

—

600

—

1

XTPBP40BC1

0.4

0.25–0.4

5.6

50

—

600

—

600

—

XTPBP63BC1

0.63

0.4–0.63

8.8

50

—

600

—

600

—

XTPB001BC1

1

0.63–1

14

50

—

600

—

600

—

1

XTPB1P6BC1

1.6

1–1.6

22

50

—

600

—

600

—

XTPB2P5BC1

2.5

1.6–2.5

35

50

—

600

—

600

—

1

XTPB004BC1

4

2.5–4

56

50

—

600

—

600

—

XTPB6P3BC1

6.3

4–6.3

88

50

—

600

—

600

—

XTPB010BC1

10

6.3–10

140

30

50

600

600

600

600

XTPB012BC1

12

8–12

168

10

50

150

600

125 5

600

1

1

1
1
1
1
1
1
1

Maximum rms
Sym Current—
480V (kA)

w/Current
Limiter—
XTPAXCL

Maximum Fuse
Rating (A)

w/Current
Limiter—
XTPAXCL

Circuit Breaker
Maximum (A)

w/Current
Limiter—
XTPAXCL

16

10–16

224

10

50

150

600

125 5

600

4

20

16–20

280

10

18

150

600

125

600

XTPB025BC1 4

25

20–25

350

10

18

150

600

125

600

XTPB016BC1
XTPB020BC1

Notes
1 N = Not required.
2 XTPR…BC1, XTPT, XTPM—Required back-up fuse if the short-circuit current exceeds the rated conditional short-circuit current (I > I ); XTPB, XTPR…DC1—Fuse (A gG/gL) for enhancing the
cc q
switching capacity of the motor protective circuit breaker to 100 kA.
3 No upstream protective device required, as it is the auto-protected range (100/150 kA—Frame B, 150 kA—Frame D).
4 IEC/EN 60947-4-1.
5 22 kA 600 Vac.

1
1
1
1
1
1
V5-T1-182

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

UL 508/CSA C22.2 No. 14—XTPR—Frame B (all Screw and Spring Cage Terminal Options),
Manual Motor Protector with Thermal and Magnetic Trip
FLA
Adjustment
Range/Overload
Release—
Ir (Amps)

Short
Circuit
Release—
Irm (Amps)

1
1
1

Maximum Protective Device for UL/CSA Group Protection

Catalog Number

Rated
Uninterrupted
Current—
Iu (Amps)

XTPRP16BC1

0.16

0.1–0.16

2.2

50

—

600

—

600

—

XTPRP25BC1

0.25

0.16–0.25

3.5

50

—

600

—

600

—

XTPRP40BC1

0.4

0.25–0.4

5.6

50

—

600

—

600

—

XTPRP63BC1

0.63

0.4–0.63

8.8

50

—

600

—

600

—

XTPR001BC1

1

0.63–1

14

50

—

600

—

600

—

XTPR1P6BC1

1.6

1–1.6

22

50

—

600

—

600

—

XTPR2P5BC1

2.5

1.6–2.5

35

50

—

600

—

600

—

XTPR004BC1

4

2.5–4

56

50

—

600

—

600

—

XTPR6P3BC1

6.3

4–6.3

88

50

—

600

—

600

—

XTPR010BC1

10

6.3–10

140

30

50

600

600

600

600

XTPR012BC1

12

8–12

168

10

50

150

600

125

600

XTPR016BC1

16

10–16

224

10

50

150

600

125 1

600

XTPR032BC1

32

25–32

448

10

18

150

600

125

600

XTPR025BC1

25

20–25

350

10

18

150

600

125

600

XTPR032BC1

32

25–32

448

10

18

150

600

125

600

Maximum rms
Sym Current—
480V (kA)

w/Current
Limiter—
XTPAXCL

Maximum Fuse
Rating (A)

w/Current
Limiter—
XTPAXCL

Circuit Breaker
Maximum (A)

w/Current
Limiter—
XTPAXCL

1
1
1
1
1
1
1
1
1
1
1

UL 508/CSA C22.2 No. 14—XTPR—Frame D, Manual Motor Protector with Thermal and Magnetic Trip
FLA
Adjustment
Range/Overload
Release—
Ir (Amps)

Short
Circuit
Release—
Irm (Amps)

1
1

Maximum Protective Device for UL/CSA Group Protection

Catalog Number

Rated
Uninterrupted
Current—
Iu (Amps)

XTPR016DC1

16

10–16

224

65

—

600

—

600

—

XTPR025DC1

25

16–25

350

65

—

600

—

600

—

XTPR032DC1

32

25–32

448

65

—

600

—

600

—

XTPR040DC1

40

32–40

560

65

—

600

—

600

—

XTPR050DC1

50

40–50

700

65

—

600

—

600

—

XTPR058DC1

58

50–58

812

65

—

600

—

600

—

XTPR063DC1

65

55–63

882

65

—

600

—

600

—

Maximum rms
Sym Current—
480V (kA)

w/Current
Limiter—
XTPAXCL

Maximum Fuse
Rating (A)

w/Current
Limiter—
XTPAXCL

Circuit Breaker
Maximum (A)

w/Current
Limiter—
XTPAXCL

1
1
1
1
1
1

Note
1 22 kA 600 Vac.

1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-183

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

UL 508 Type E Ratings—XTPR Frame B + XTPAXLSA
Maximum Upstream
Protective Device (A) 1

Line Side
Adapter
Catalog Number

FLA
Adjustment
Range/Overload
Release—
Ir (Amps)

XTPRP16BB1

XTPAXLSA

0.1–0.16

2.2

50

50

XTPRP16BC1

XTPAXLSA

0.16–0.25

3.5

50

50

1

XTPRP25BC1

XTPAXLSA

0.25–0.4

5.6

50

50

50

XTPRP40BC1

XTPAXLSA

0.4–0.63

8.82

50

50

50

Not required

Not required

1

XTPRP63BC1

XTPAXLSA

0.63–1

14

50

50

50

Not required

Not required

XTPR001BC1

XTPAXLSA

1–1.6

22.4

50

50

50

Not required

Not required

1
1
1

1
1

Manual Motor
Protector—
Screw Terminal
Catalog Number

Short
Circuit
Release—
Irm (Amps)

UL 508 Type E Application
Maximum rms Symmetrical Short-Circuit Ratings (kA)
240V

480/277V

Maximum Fuse
600V

Maximum
Circuit Breaker
600V

50

Not required

Not required

50

Not required

Not required

Not required

Not required

600/347V

XTPR1P6BC1

XTPAXLSA

1.6–2.5

35

50

50

50

Not required

Not required

XTPR2P5BC1

XTPAXLSA

2.5–4

56

50

50

50

Not required

Not required

XTPR004BC1

XTPAXLSA

4–6.3

88.2

50

50

50

Not required

Not required

XTPR6P3BC1

XTPAXLSA

6.3–10

140

50

50

50

Not required

Not required

XTPR010BC1

XTPAXLSA

8–12

168

42

42

—

Not required

Not required

1

XTPR012BC1

XTPAXLSA

10–16

224

42

42

—

Not required

Not required

1

XTPR016BC1

XTPAXLSA

10–16

224

18

18

—

Not required

Not required

XTPR020BC1

XTPAXLSA

16–20

280

18

18

—

Not required

Not required

1

XTPR025BC1

XTPAXLSA

20–25

350

18

18

—

Not required

Not required

XTPR032BC1

XTPAXLSA

25–32

448

18

18

—

Not required

Not required

1

1
1

UL 508 Type E Ratings—XTPR Frame D + XTPAXLSAD

1

Manual Motor
Protector—
Screw Terminal
Catalog Number

1

Maximum Upstream
Protective Device (A) 1

Line Side
Adapter
Catalog Number

FLA
Adjustment
Range/Overload
Release—
Ir (Amps)

Short
Circuit
Release—
Irm (Amps)

UL 508 Type E Application
Maximum rms Symmetrical Short-Circuit Ratings (kA)
240V

480/277V

XTPR016DC1

XTPAXLSAD

10–16

224

65

XTPR025DC1

XTPAXLSAD

16–25

350

65

1

XTPR032DC1

XTPAXLSAD

25–32

448

XTPR040DC1

XTPAXLSAD

32–40

1

XTPR050DC1

XTPAXLSAD

XTPR058DC1
XTPR063DC1

1

1
1
1

600/347V

Maximum Fuse
600V

Maximum
Circuit Breaker
600V

65

25

Not required

Not required

65

25

Not required

Not required

65

65

25

Not required

Not required

560

65

65

25

Not required

Not required

40–50

700

65

65

—

Not required

Not required

XTPAXLSAD

50–58

812

65

65

—

Not required

Not required

XTPAXLSAD

55–65

882

65

65

—

Not required

Not required

Note
1 For UL 508 Type E applications, the manual motor protector assembly does not require a dedicated upstream protective
device in the panel, thus a maximum rating is not required.

1
1
1
1
1
1
1
1
V5-T1-184

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Dimensions

1

Approximate Dimensions in mm [in]

1

Manual Motor Protectors, Manual Transformer
Protectors—XTPR…B

Manual Motor Protectors—XTPB

1
93
[3.66]

XTPAXFA _

XTPAXFA _

45
[1.77]

1

XTPAXFA _

93
[3.66]

45
[1.77]

1
1

50
[1.97]

45
[1.77]

44
[1.73]

5.5
[.22]

45
[1.77]

XTPAXFA _

1

88 [3.46]
94 [3.70]

74 [2.91]
85 [3.35]

1
1

Manual Motor Protector—XTPR…DC1

1
1

4 [.16]

1
140
[5.57]

65
45 [2.56] 125
[4.92]
[1.77]

XTPAXFA _

130
[5.12]

1
1
1
1

XTPAXFA _

30
[1.18]

7.5 [.30]

1

118 [4.65]

55 [2.17]

1

127 [5.00]
145 [5.71]

1

171 [6.73]

1

MMPs with Early-Make Auxiliary Contacts—
XTPR…BC1 + XTPAXFAEM20

Current Limiter—XTPAXCL
45
[1.77]
28
[1.10]

1

80 [3.15]

1
*

XTPAXFAEM20

93
[3.66]

45
55
[1.77] [2.17]

93
[3.66]

90
73
[3.54] [2.87]

1
1
1

7.5
[.30]
* IEC/EN 60715 DIN Rail

44
[1.73]
49.5
[1.95]

7.5
[.30]
70
[2.76]

45
[1.77]

50
[1.97]

XTPAXFAEM20

68 [2.68]
86 [3.39]

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-185

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

Approximate Dimensions in mm [in]

1

Standard Auxiliary Contact—XTPAXSA_

Three-Phase Commoning Link—XTPAXCLKB5,
XTPAXCLKB4, XTPAXCLKB3 and XTPAXCLKB2
261 [10.28] (207 [8.15],
153 [6.02], 99 [3.90])

1
1

45
90
[1.77] [3.54]

36
[1.42]

27
[1.06]

1
1
1

54
[2.13]
9
[.35]

26
[1.02]

Overlapping Mounting
to Extend the Three-Phase
Commoning Link

68 [2.68]

1
1

Three-Phase Commoning Link—XTPAXCLKC4, XTPAXCLKC2
Trip Indicating Auxiliary Contact—XTPAXSATR_

234 [9.21] (108 [4.25])

1
1
45
90
[1.77] [3.54]

36
[1.42]

1

63
[2.48]

27
[1.06]

1
1

9
[.35]

26
[1.02]
68 [2.68]

1

Incoming Terminal, Line Side Adapter—XTPAXIT, XTPAXLSA

1
1

56
[2.20]

Undervoltage/Shunt Release—XTPAXUVR_, XTPAXSR_
7.5
[.30]

31
[1.22]

1

XTPAXLSA

1

73
[2.87]

45
90
[1.77] [3.54]

36
[1.42]

48
[1.89]

1
1
1

41
[1.61]
18
[.71]

49
[1.93]

XTPAXIT

68 [2.68]

1
1
1

Three-Phase Commoning Link—XTPAXCLKA4, XTPAXCLKA2
180 [7.09] (90 [3.54])

1
1
45
[1.77]

1

27
[1.06]

1
1
V5-T1-186

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

Three-Phase Commoning Link
XTPAXCLKA4D, XTPAXCLKA3D and XTPAXCLKA2D

XTPAXCLKC4D and XTPAXCLKC2D

1

XTPAXCLKA4D

XTPAXCLKC4D

1

36
[1.42]

36
[1.42]

205 [8.07]

14
[.55]

1
260 [10.24]

33
[1.30]

XTPAXCLKC2D

36
[1.42]

36
[1.42]
14
[.55]

33
[1.30]

1
1

XTPAXCLKA3D

151 [5.94]

14
[.55]

33
[1.30]

1
1

115 [4.53]

14
[.55]

1

33
[1.30]

1
1

XTPAXCLKA2D

1
36
[1.42]

1
98 [3.86]

14
[.55]

33
[1.30]

1
1

XTPAXCLKB4D, XTPAXCLKB3D and XTPAXCLKB2D

1

XTPAXCLKB4D

1
36
[1.42]

1
232 [9.13]

33
[1.30]

14
[.55]

1
1

XTPAXCLKB3D

1
1

36
[1.42]
170 [6.69]

14
[.55]

1

33
[1.30]

1
1

XTPAXCLKB2D

1

36
[1.42]
117 [4.6]

14
[.55]

1

33
[1.30]

1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-187

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Insulated Enclosures for Surface Mounting of XTPB Manual Motor Protectors

1
1
1

158
[6.22]

158
[6.22]

1
80 [3.15]

1
1

80 [3.15]

116.5 [4.59]

XTPBXENCS40, XTPBXENCS65, XTPBXENAS41, XTPBXENAS65

116.5 [4.59]
177.2 [6.98]

XTPBXENCSEK65, XTPBXENCSES65, XTPBXENASEK65, XTPBXENASES65

1
1
1

158
[6.22]

1
1
1

80 [3.15]

116.5 [4.59]
129.5 [5.10]

XTPBXENCSLE65, XTPBXENCSLO65, XTPBXENASLE65, XTPBXENASO065

1
1

Insulated Enclosures for Flush Mounting of XTPB Manual Motor Protectors

1

69
[2.72]

69
[2.72]

1
1
1

129
[5.08]

129
[5.08]

1
90.2
[3.55]

1
1

90.2
[3.55]

93 [3.66]
115.2 [4.54]

XTPBXENCF40, XTPBXENCF55

93 [3.66]
115.2 [4.54]
175.9 [6.93]

XTPBXENCFEK55, XTPBXENCFES55

69
[2.72]

1
1
1

129
[5.08]

1
1
1

90.2
[3.55]

93 [3.66]
115.2 [4.54]

XTPBXENCFLE55, XTPBXENCFLO55

1
V5-T1-188

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Approximate Dimensions in mm [in]

1

Insulated Enclosures for Surface Mounting of XTPR…B Manual Motor Protectors

1

Drilling Dimensions
4.5 [.18]

1
1

70
[2.76]

158
[6.22]

153
[6.02]

158
[6.22]

1
1

80 [3.15]

8 [.31]
4.5
97.5 [3.84]
[.18]
125.5 [4.94]
XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY

90 [3.54]
100 [3.94]

1

80 [3.15]

XTPAXENCS40

1

98 [3.86]

1

30 [1.18]
SVB-PKZ0-CI
44
[1.73]

97.5 [3.84]

30
[1.18]
28
[1.10]

Drilling Dimensions
4.5
[.18]

1
1

33
[1.30]
55
[2.17]

158
[6.22]

1

153
[6.02]

1
1

4.5
[.18]

80 [3.15]
XTPAXENCS55_ + XTPAXPL1, XTPAXENCSEM55_ + XTPAXPL1

1

8
[.31]
Drilling Dimensions
M4

1
1

181
160
[7.13] [6.30]

181 160
[7.13] [6.30]

47.5
100
[1.87]
[3.94]
104
[4.09]
XTPAXENCSH41, XTPAXENCS41, XTPAXENAS41

47.5
M4
[1.87]
103 [4.06]
130 [5.12]
XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY,
XTPAXENAS55B, XTPAXENAS55RY, XTPAXENASEM55B, XTPAXENASEM55RY,
XTPAXENCSH65B, XTPAXENCSH65RY, XTPAXENCSEMH65B, XTPAXENCSEMH65RY

1

171
[6.73]

1
1

100
[3.94]

1
1
1

98 [3.86]
30 [1.18]
SVB-PKZ0-CI
44
[1.73]

114 [4.49]

30
[1.18]
28
[1.10]

1

Drilling Dimensions
M4

1
1

33
[1.30]
55
[2.17]

1

171
[6.73]

181 160
[7.13] [6.30]

1
97 [3.82]

1

M4

1

XTPAXENCS65_ + XTPAXPL1, XTPAXENCSEM65_ + XTPAXPL1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-189

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Insulated Enclosures for Flush Mounting of XTPR…B Manual Motor Protectors
69
[2.72]

1
1

129
[5.08]

4 [.16]
R

55
[2.17]

116 – 118
[4.57 – 4.64]

1
1

85 [3.35]

80 [3.15]
96 [3.78]

1
1

XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY

1

Mounting Cutout XTPAXENCF_

98
[3.86]
30
[1.18]

1
1

70 – 72
[2.76 – 2.83]

124 [4.88]

30
[1.18]

58
[2.28]

28 [1.10]

1
1
55
[2.17]

1

21
[.83]

129
[5.08]

1
1
1

80 [3.15]

85
[3.35]

96 [3.78]
124 [4.88]
XTPAXENCF55_ + XTPAXPL3

1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-190

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

Insulated Enclosures for Surface Mounting of XTPR…D Manual Motor Protectors

1

98 [3.86]

3 [.12]

1

32 [1.26]
SVB-PKZ4-CI

1
1

240
[9.45]

1
72
[2.83]

1
1

160 [6.30]

1

134 [5.28]
181 [7.13]

1

197 [7.76]
XTPAXENCSD65B, XTPAXENCSD65RY

XTPAXENCSD65_ + XTPAXPL2

1
Drilling Dimensions
5.6 [.22]
Dia.

1
1

72
[2.83]

1
1
240
[9.45]

193
[7.60]

1
1
1
1

160 [6.30]

186 [7.32]

28 [1.10]

142 [5.60]

1

30
[1.18]

XTPAXENCSD65

1

Rotary Handle Mechanism—XTPAXRHM_

1

43 [1.69] Dia.

1

64
[2.52]
64
[2.52]

19.5
[.77]

1

48
[1.89]

1

48
[1.89]

1

62
[2.44]

At least 100 [3.94]
up to Cover Hinge

1
1

Mounting Depth:
100 – 240 [3.94 – 9.45]
from the top edge of
the mounting rail to the
front edge of the panel
door/cover

1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-191

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
Pushbutton MMP Enclosures
Insulated Enclosures for
Surface Mounting

Insulated Enclosures for
Flush Mounting

1

XTPB Pushbutton MotorProtective Circuit Breakers

Frame B (0.1–32A) XTPR
Motor-Protective Circuit
Breakers

Frame B XTPR (0.1–32A)
Rotary Motor-Protective
Circuit Breakers with
XTPAXFAEM20 Early-Make
Front-Mount Auxiliary Contact

1

Catalog Number

Catalog Number

Catalog Number

1

XTPBXENCS40

158 x 80 x 116.5
[6.22 x 3.15 x 4.59]

XTPAXENCS41

160 x 100 x 104
[6.30 x 3.94 x 4.09]

XTPAXENCSEM65B

1

XTPBXENCS65

158 x 80 x 116.5
[6.22 x 3.15 x 4.59]

XTPAXENCS65B

160 x 100 x 130
[6.30 x 3.94 x 5.12]

XTPAXENCSEM65RY 160 x 100 x 130
[6.30 x 3.94 x 5.12]

1

XTPBXENCSLO65

158 x 80 x 129.5
[6.22 x 3.15 x 5.10]

XTPAXENCS65RY

160 x 100 x 130
[6.30 x 3.94 x 5.12]

XTPAXENCSEM55B

158 x 80 x 100
[6.22 x 3.15 x 3.94]

1

XTPBXENCSLE65

158 x 80 x 129.5
[6.22 x 3.15 x 5.10]

XTPAXENCS40

158 x 80 x 100
[6.22 x 3.15 x 3.94]

XTPAXENCSEM55RY 158 x 80 x 100
[6.22 x 3.15 x 3.94]

1

XTPBXENCSES65

158 x 80 x 177.2
[6.22 x 3.15 x 6.98]

XTPAXENCS55B

158 x 80 x 125.5
[6.22 x 3.15 x 4.94]

1

XTPBXENCSEK65

158 x 80 x 177.2
[6.22 x 3.15 x 6.98]

XTPAXENCS55RY

158 x 80 x 125.5
[6.22 x 3.15 x 4.94]

1
HxWxD

Global Usage

HxWxD

Global Usage

Global Usage

1

160 x 100 x 130
[6.30 x 3.94 x 5.12]

XTPB Pushbutton Manual
Motor Protectors

Frame B (0.1–32A) XTPR
Rotary Manual Motor
Protectors

Frame B XTPR (0.1–32A)
Rotary Manual Motor
Protectors with
XTPAXFAEM20 Early-Make
Front-Mount Auxiliary Contact

Catalog Number

Catalog Number

Catalog Number

1
1

HxWxD

HxWxD

HxWxD

HxWxD

XTPB Pushbutton Manual
Motor Protectors
Catalog Number

HxWxD

Global and
North American Usage
XTPBXENCF40

129 x 90.2 x 115.2
[5.08 x 3.55 x 4.54]

XTPBXENCF55

129 x 90.2 x 115.2
[5.08 x 3.55 x 4.54]

XTPBXENCFLO55

129 x 90.2 x 115.2
[5.08 x 3.55 x 4.54]

XTPBXENCFLE55

129 x 90.2 x 115.2
[5.08 x 3.55 x 4.54]

XTPBXENCFES55

129 x 90.2 x 175.9
[5.08 x 3.55 x 6.93]

XTPBXENCFEK55

129 x 90.2 x 175.9
[5.08 x 3.55 x 6.93]

Frame B (0.1–32A) XTPR
Rotary Manual Motor
Protectors
Catalog Number

HxWxD

North American Usage

North American Usage

North American Usage

Global Usage

XTPBXENAS41

XTPAXENAS55B

160 x 100 x 130
[6.30 x 3.94 x 5.12]

XTPAXENCSEM55B

XTPAXENCF40

1

158 x 80 x 116.5
[6.22 x 3.15 x 4.59]

129 x 85 x 96
[5.08 x 3.35 x 3.78]

XTPBXENAS65

XTPAXENAS55RY

160 x 100 x 130
[6.30 x 3.94 x 5.12]

XTPAXENCSEM55RY 160 x 100 x 130
[6.30 x 3.94 x 5.12]

XTPAXENCF55B

1

158 x 80 x 116.5
[6.22 x 3.15 x 4.59]

129 x 85 x 124
[5.08 x 3.35 x 4.88]

XTPBXENASLO65

158 x 80 x 129.5
[6.22 x 3.15 x 5.10]

XTPAXENCF55RY

129 x 85 x 124
[5.08 x 3.35 x 4.88]

1

1

XTPBXENASLE65

158 x 80 x 129.5
[6.22 x 3.15 x 5.10]

1

XTPBXENASES65

158 x 80 x 177.2
[6.22 x 3.15 x 6.98]

1

XTPBXENASEK65

158 x 80 x 177.2
[6.22 x 3.15 x 6.98]

1

160 x 100 x 130
[6.30 x 3.94 x 5.12]

Frame D (10–65A) Rotary
Motor-Protective Circuit
Breakers
Catalog Number

HxWxD

Global and
North American Usage
XTPAXENCSD65B

240 x 160 x 197
[9.45 x 6.30 x 7.76]

XTPAXENCSD65RY

240 x 160 x 197
[9.45 x 6.30 x 7.76]

1
1
1
1
1
1
1
1
V5-T1-192

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Contents

Combination Motor Controllers

Description

Page

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-3
V5-T1-18
V5-T1-35
V5-T1-128
V5-T1-141
V5-T1-157
V5-T1-194
V5-T1-194
V5-T1-195
V5-T1-195
V5-T1-203
V5-T1-205
V5-T1-211

An Eaton
Green Solution

XT Electronic Manual Motor Protector . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

V5-T1-216
V5-T1-229

1
1
1
1
1
1
1
1
1
1

Combination Motor Controllers

1

Product Description

Application Description

Eaton’s XT IEC open nonreversing and reversing
manual motor controllers
combine a manual motor
protector with an IEC
contactor(s) to provide a
complete motor protection
solution by combining motor
disconnect function, thermal
overload protection, magnetic
short-circuit protection and
remote control operation in
one compact, assembled
unit. these assembled
manual motor controllers
cover motors with FLA
ratings from 0.10A to 65A.

The XT IEC non-reversing and
reversing manual
and combination motor
controllers can be used in
the following applications:

1

The UL 508 Type F labeled
combination motor controller
(CMC) includes a line side
adapter (LSA). These
assembled combination
motor controllers cover
motors with FLA ratings
from 0.10A to 65A.

Group Motor Control
Manual motor controllers
(MMCs) are ideal for group
motor applications where an
upstream breaker or fuse
provides protection for two or
more motors. XT manual
motor controllers (MMC)
combine a manual motor
protector, a wiring connector
link and IEC contactor.

1
1
Individual Branch Circuit for Motor Loads
Combination motor controller
The manual motor protector
(CMC), consisting of a line
was invented in Germany by
side adapter, manual motor
Moeller to correct this
protector, wiring connector
inefficiency. The MMP
link and IEC contactor,
operates similarly to a circuit
provide an efficient means to
breaker, except the inrush
build an entire branch circuit.
(magnetic) protection is set to
The XT CMC is UL 508 Type
14 times the running current,
F approved, meaning it is
thus accounting for motor
“self-protected” and doesn’t
start-up current without the
require the use of an
necessity to oversize. A
additional fuse or breaker for
overcurrent dial was added to
short circuit protection. This
the face of the MMP to serve
approval means CMC’s can
as the motor overload
be used in place of a
protection. This “motor
traditional fuse-starter and
protective circuit breaker”, as
breaker-starter motor circuit.
it is referred to in Europe,
now accomplishes all four
Based around two key
key functions of a motor
functional components (MMP
branch circuit: disconnect,
and contactor), the CMC is a
short circuit, motor controller
very cost effective means to
and motor overload
build a branch circuit. Fuses
protection. With the addition
and breakers must be
of a contactor, users have the
oversized to prevent tripping
ability to remotely control the
during motor start up, and
starter device.
thus these oversized devices
can no longer protect the
Whether a single motor
motor. To compensate for
application or a multiple
this, a motor overload relay is
motor application, CMC’s are
necessary to protect the
an ideal solution for
motor.
machinery OEMs and panel
builders.

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-193

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

●

●
●
●

●

1

●

1
1
1
1
1
1

●
●
●

●

●
●

●

1

●

1

●

1
1

●

1

●

1
1

XT IEC Power Control

Features

1

1

IEC Contactors and Starters

Standards and Certifications

ON/OFF rotary handle
with lockout provision
Visible trip indication
Test trip function
Motor applications
from 0.10A to 65A
Class 10 overload
protection
Built-in heater and
magnetic trip elements
to protect the motor
Phase loss sensitivity
Type 2 coordination
Ambient compensated
up to 55°C [140°F]
Control inputs located at
front of starter for easy
access and wiring
Wide range of coils
DIN rail mount—
XTSC…BB_
Mounting plates—
XTSC…BC_, XTSC…D
motor controllers
Adjustment dial for setting
motor FLA
Short-circuit trip at
14 times the maximum
setting of the FLA
adjustment dial
UL 508 Type F CMC high
fault short-circuit ratings
1NO-1NC auxiliary contact
as standard on manual
motor controller and
combination motor
controller

MMC and CMC Applications

UL 508 Type F combination
motor controller
●

●
●

XTIEC Manual and Combination Motor Controllers

IEC Type 2 Approved per
IEC 60947-4-1
UL Listed File No. E245398
CE Mark

Manual Motor Controller
Use in group installation
applications. Upstream
SCPD 1 is required and must
be sized smaller than the
maximum upstream SCPD 1
rating on each MMC 2 used.
Line
Side
Adapter
Tap
rules
should
also be(LSA)
observed.
Not required

Note: For Type 2 Coordination of
MMCs, see Page V5-T1-230.
Protection in different controller
types

Manual Motor Controller
XTSC/XTSR

Combination Motor Controller
XTFC/XTFR

Technical Paper AP03402001E.
Line side adapters are not required for non-U.S. applications.
Most countries outside of the U.S. classify the MMP as a
motor-protective circuit breaker.
1
2

SCPD = Short-circuit protective device (circuit breaker, fuses).
MMC = Manual motor controller

1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

Line Side Adapter (LSA)
Required—factory assembled

Notes

1

V5-T1-194

UL 508 Type F Combination
Motor Controller
Use for single motor branch circuits or use
multiple CMC’s for a multiple motor panel
applications. No additional SCPD 1 is required
in the branch, as these devices are “selfprotected”.

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Catalog Number Selection

1

Combination Motor Controllers

1

XT SC 012 B B A
Designation
XT = XT IEC power control
SC

=

SR

=

FC

=

FR

=

Type
Manual motor controller—
FVNR
Manual motor controller—
FVR
Combination motor controller,
UL 508 Type F—FVNR
Combination motor controller,
UL 508 Type F—FVR

Rated Current of MMP
Frame B
Frame D
P16 = 0.16A 016 = 16A
P25 = 0.25A 025 = 25A
P40 = 0.40A 032 = 32A
P63 = 0.63A 040 = 40A
001 = 1A
050 = 50A
1P6 = 1.6A
058 = 58A
2P5 = 2.5A
063 = 63A
004 = 4A
6P3 = 6.3A
010 = 10A
012 = 12A
016 = 16A
020 = 20A
025 = 25A
032 = 32A

1
Frame Size—Contactor
B = 45 mm, 7 to 15A
C = 45 mm, 18 to 32A
D = 55 mm, 40 to 65A

A
B
C
D
E
F
G
H
L
N
P
R
T
W
Y
AD
BD
RD
TD
WD

Frame Size—MMP
B = 45 mm, 0.1 to 32A
D = 55 mm, 16 to 63A

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

Coil Voltage
110V 50 Hz, 120V 60 Hz
220V 50 Hz, 240V 60 Hz
415V 50 Hz, 480V 60 Hz
550V 50 Hz, 600V 60 Hz
208V 50 Hz
230V 50 Hz
190V 50 Hz, 220V 60 Hz
240V 50 Hz, 277V 60 Hz
380V 50 Hz, 440V 60 Hz
400V 50 Hz
380V 60 Hz
12V 50/60 Hz
24V 50/60 Hz
42V 50 Hz, 48V 60 Hz
48V 50 Hz
120 Vdc
220 Vdc
12 Vdc
24 Vdc
48 Vdc

1
1
1
1
1
1
1
1
1
1

Product Selection

1

XTSC and XTSR Manual Motor Controllers (MMC)/Starter Combinations
Frame B MMP +
Frame B Contactor

1

Factory-Assembled Manual Motor Controller—Frame B MMP + Frame B Contactor—
Maximum UL Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Short-Circuit
Release—
Irm (Amps)

Three-Phase

Assembled Manual Motor Controller 2
Reversing
Catalog Number

200V

240V

480V

600V

Non-Reversing
Catalog Number

3.2

3

3

1/2

1/2

XTSCP16BB_

XTSRP16BB_

0.16–0.25

3.5

3

3

1/2

1/2

XTSCP25BB_

XTSRP25BB_

0.25–0.4

5.6

3

3

1/2

1/2

XTSCP40BB_

XTSRP40BB_

0.4–0.63

8.82

3

3

1/2

1/2

XTSCP63BB_

XTSRP63BB_

0.63–1

14

3

3

1/2

1/2

XTSC001BB_

XTSR001BB_

1–1.6

22.4

3

3

3/4

1

XTSC1P6BB_

XTSR1P6BB_

0.1–0.16

1.6–2.5

35

1/2

1/2

1

1-1/2

XTSC2P5BB_

XTSR2P5BB_

2.5–4

56

1

1

2

3

XTSC004BB_

XTSR004BB_

4–6.3

88.2

1-1/2

1-1/2

3

5

XTSC6P3BB_

XTSR6P3BB_

6.3–10

140

3

3

7-1/2

3

XTSC010BB_

XTSR010BB_

8–12

168

3

3

7-1/2

3

XTSC012BB_

XTSR012BB_

10–16

224

3

3

10

3

XTSC016BB_

—

1
1
1
1
1
1
1
1
1

Notes
1 Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-198.
3 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).

1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-195

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame B MMP +
Frame B Contactor

IEC Contactors and Starters
XT IEC Power Control

Factory-Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor—
Maximum IEC Ratings1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Short-Circuit
Release—
Irm (Amps)

1

Assembled Manual Motor Controller 2

Three-Phase
220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

0.1–0.16

3.2

—

—

—

0.06

XTSCP16BB_

XTSRP16BB_

0.16–0.25

3.5

—

0.06

0.06

0.12

XTSCP25BB_

XTSRP25BB_

0.25–0.4

5.6

0.06

0.09

0.12

0.18

XTSCP40BB_

XTSRP40BB_

0.4–0.63

8.82

0.09

0.18

0.25

0.25

XTSCP63BB_

XTSRP63BB_

1

0.63–1

14

0.12

0.25

0.37

0.55

XTSC001BB_

XTSR001BB_

1–1.6

22.4

0.25

0.55

0.75

1.1

XTSC1P6BB_

XTSR1P6BB_

1

1.6–2.5

35

0.37

0.75

1.1

1.5

XTSC2P5BB_

XTSR2P5BB_

2.5–4

56

0.75

1.5

2.2

3

XTSC004BB_

XTSR004BB_

1
1

1

4–6.3

88.2

1.1

2.2

3

4

XTSC6P3BB_

XTSR6P3BB_

1

6.3–10

140

2.2

4

4

7.5

XTSC010BB_

XTSR010BB_

8–12

168

3

5.5

5.5

11

XTSC012BB_

XTSR012BB_

1

10–16

224

4

7.5

9

12.5

XTSC016BB_

—

1
1

Frame B MMP +
Frame C Contactor

Factory-Assembled Manual Motor Controller—Frame B MMP + Frame C Contactor—
Maximum UL Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Assembled Manual Motor Controller 2

Short-Circuit
Release—
Irm (Amps)

200V

240V

480V

10–16

224

3

3

1

16–20

280

5

5

20–25

350

5

1

25–32

448

7-1/2

1

1
1

Frame B MMP +
Frame C Contactor

1

Short-Circuit
Release—
Irm (Amps)

1

600V

Non-Reversing
Catalog Number

Reversing
Catalog Number

10

10

XTSC016BC_

XTSR016BC_

10

15

XTSC020BC_

XTSR020BC_

7-1/2

15

20

XTSC025BC_

XTSR025BC_

10

20

25

XTSC032BC_

XTSR032BC_

Factory-Assembled Manual Motor Controller—Frame B MMP + Frame C Contactor—
Maximum IEC RatingS 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1

Three-Phase

Assembled Manual Motor Controller 2

Three-Phase
220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

10–16

224

4

7.5

9

12.5

XTSC016BC_

XTSR016BC_

16–20

280

5.5

9

12.5

15

XTSC020BC_

XTSR020BC_

20–25

350

5.5

11

15

22

XTSC025BC_

XTSR025BC_

1

25–32

448

7.5

15

22

30

XTSC032BC_

XTSR032BC_

1

Notes
1 Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-198.

1

1
1
1
1
V5-T1-196

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Frame D MMP +
Frame C Contactor

Factory-Assembled Manual Motor Controller—Frame D MMP + Frame C Contactor—
Maximum UL Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

10–16

Frame D MMP +
Frame C Contactor

1
1

Assembled Manual Motor Controller 2

Short-Circuit
Release—
Irm (Amps)

200V

240V

480V

224

3

5

Three-Phase
600V

Non-Reversing
Catalog Number

Reversing
Catalog Number

10

15

XTSC016DC_

XTSR016DC_

16–25

350

5

7-1/2

15

20

XTSC025DC_

XTSR025DC_

25–32

448

7-1/2

10

25

30

XTSC032DC_

XTSR032DC_

Short-Circuit
Release—
Irm (Amps)

1
1
1

Assembled Manual Motor Controller 2

Three-Phase

1

1

Factory-Assembled Manual Motor Controller—Frame D MMP + Frame C Contactor—
Maximum IEC Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1

1

220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

1
1

10–16

224

4

7.5

9

12.5

XTSC016DC_

XTSR016DC_

16–25

350

5.5

12.5

12.5

22

XTSC025DC_

XTSR025DC_

25–32

448

7.5

15

17.5

22

XTSC032DC_

XTSR032DC_

1
1

Frame D MMP +
Frame D Contactor

Factory-Assembled Manual Motor Controller—Frame D MMP + Frame D Contactor—
Maximum UL Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Assembled Manual Motor Controller 2

Short-Circuit
Release—
Irm (Amps)

200V

240V

480V

32–40

560

10

15

40–50

700

15

50–58

812

15

55–65

882

15

Three-Phase
600V

Non-Reversing
Catalog Number

Reversing
Catalog Number

30

30

XTSC040DD_

XTSR040DD_

15

30

—

XTSC050DD_

XTSR050DD_

15

40

—

XTSC058DD_

XTSR058DD_

15

40

—

XTSC063DD_

XTSR063DD_

1
1
1
1
1

Notes
1 Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-198.

1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-197

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

Frame D MMP +
Frame D Contactor

1

Factory-Assembled Manual Motor Controller—Frame D MMP + Frame D Contactor—
Maximum IEC Ratings 1

Short-Circuit
Release—
Irm (Amps)

1
1
1
1

XT IEC Power Control

FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1

1

IEC Contactors and Starters

Assembled Manual Motor Controller 2

Three-Phase
220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

32–40

560

11

20

22

30

XTSC040DD_

XTSR040DD_

40–50

700

14

25

30

45

XTSC050DD_

XTSR050DD_

50–58

812

17

30

37

55

XTSC058DD_

XTSR058DD_

55–65

882

18.5

34

37

55

XTSC063DD_

XTSR063DD_

AC and DC Coil Suffixes
Suffix Code

Coil Voltage

Suffix Code

110V 50 Hz, 120V 60 Hz

A

380V 50 Hz, 440V 60 Hz

L

110V 50 Hz, 120V 60 Hz

1

220V 50 Hz, 240V 60 Hz

B

400V 50 Hz

N

220V 50 Hz, 240V 60 Hz

230V 50 Hz

F

380V 60 Hz

P

1

24V 50/60 Hz

T

12V 50/60 Hz

24 Vdc

TD 3

1

415V 50 Hz, 480V 60 Hz

C

1

1
1
1
1
1
1
1
1
1
1

Coil Voltage

Coil Voltage

Suffix Code

A

380V 50 Hz, 440V 60 Hz

L

B

400V 50 Hz

N

230V 50 Hz

F

380V 60 Hz

P

R

24V 50/60 Hz

T

12V 50/60 Hz

R

42V 50 Hz, 48V 60 Hz

W

24–27 Vdc

TD 3

42V 50 Hz, 48V 60 Hz

W

48V 50 Hz

Y

415V 50 Hz, 480V 60 Hz

C

48V 50 Hz

Y

AD

3

550V 50 Hz, 600V 60 Hz

D

110–130 Vdc

AD 3

BD

3

208V 60 Hz

E

200–240 Vdc

BD 3

RD

3

190V 50 Hz, 220V 60 Hz

G

12–14 Vdc

RD 3

240V 50 Hz, 277V 60 Hz

H

48–60 Vdc

WD 3

Frame B Contactors

550V 50 Hz, 600V 60 Hz
208V 60 Hz
190V 50 Hz, 220V 60 Hz
240V 50 Hz, 277V 60 Hz

Coil Voltage

Suffix Code

Frame C and D Contactors

D
E
G
H

120 Vdc
220 Vdc
12 Vdc
48 Vdc

WD

3

Notes
The assembled manual motor controller (MMC) consists of an XTPR manual motor protector (MMP) and an XTCE contactor. For Frame B MMP +
Frame B contactor assemblies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The contactors are supported
mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For MMCs using a Frame C or Frame D contactor,
the assembly is mounted via a DIN rail adapter plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection is made with electrical contact modules
(XTPAXECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor:
SF = 1.15 → Ir = 1 x In mot
SF = 1 → Ir = 0.9 x In mot
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
1
2
3

Select manual motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
Underscore (_) indicates magnetic coil suffix required. See AC and DC coil suffixes above.
With DC operation: Integrated diode-resistor combination, coil rating 2.6W.

Non-Reversing Manual
Motor Controller Power
Circuit

Reversing Manual
Motor Controller Power
Circuit

1
1
1
1
1

M
3~

M
3~

1
1
1
V5-T1-198

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F
Frame B MMP + Two
Frame B Contactors

1

Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame B Contactor—
Maximum UL Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Short-Circuit
Release—
Irm (Amps)

Assembled Manual Motor Controller 2
Three-Phase
200V

240V

480V

600V

Non-Reversing
Catalog Number

Reversing
Catalog Number

0.16–0.25

3.5

3

3

1/2

1/2

XTFCP25BB_

XTFRP25BB_

0.25–0.4

5.6

3

3

1/2

1/2

XTFCP40BB_

XTFRP40BB_

0.4–0.63

8.82

3

3

1/2

1/2

XTFCP63BB_

XTFRP63BB_

0.63–1

14

3

3

1/2

1/2

XTFC001BB_

XTFR001BB_

1–1.6

22.4

3

3

3/4

1

XTFC1P6BB_

XTFR1P6BB_

1.6–2.5

35

1/2

1/2

1

1-1/2

XTFC2P5BB_

XTFR2P5BB_

2.5–4

56

1

1

2

3

XTFC004BB_

XTFR004BB_

4–6.3

88.2

1-1/2

1-1/2

3

5

XTFC6P3BB_

XTFR6P3BB_

6.3–10

140

3

3

7-1/2

10

XTFC010BB_

XTFR010BB_

8–12

168

3

3

7-1/2

—

XTFC012BB_

XTFR012BB_

10–16

224

3

5

10

—

XTFC016BB_

—

1
1
1
1
1
1
1
1
1

Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame B Contactor—
Maximum IEC Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Short-Circuit
Release—
Irm (Amps)

Assembled Manual Motor Controller 2

Three-Phase
220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

0.1–0.16

2.2

—

—

—

0.06

XTFCP16BB_

XTFRP16BB_

0.16–0.25

3.5

—

0.06

0.06

0.12

XTFCP25BB_

XTFRP25BB_

0.25–0.4

5.6

0.06

0.09

0.12

0.18

XTFCP40BB_

XTFRP40BB_

0.4–0.63

8.82

0.09

0.18

0.25

0.25

XTFCP63BB_

XTFRP63BB_

0.63–1

14

0.12

0.25

0.37

0.55

XTFC001BB_

XTFR001BB_

1–1.6

22.4

0.25

0.55

0.75

1.1

XTFC1P6BB_

XTFR1P6BB_

1.6–2.5

35

0.37

0.75

1.1

1.5

XTFC2P5BB_

XTFR2P5BB_

2.5–4

56

0.75

1.5

2.2

3

XTFC004BB_

XTFR004BB_

4–6.3

88.2

1.1

2.2

3

4

XTFC6P3BB_

XTFR6P3BB_

6.3–10

140

2.2

4

4

7.5

XTFC010BB_

XTFR010BB_

8–12

168

3

5.5

5.5

11

XTFC012BB_

XTFR012BB_

10–16

224

4

7.5

9

12.5

XTFC016BB_

—

1
1
1
1
1
1
1
1
1

Notes
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.
3 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1).

1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-199

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame C Contactor—
Maximum UL Ratings 1

1

FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

200V

240V

480V

10–16

224

3

5

16–20

280

5

5

20–25

350

5

25–32

448

7-1/2

1
1
1

Assembled Manual Motor Controller 2

Short-Circuit
Release—
Irm (Amps)

Three-Phase
600V

Non-Reversing
Catalog Number

Reversing
Catalog Number

10

—

XTFC016BC_

XTFR016BC_

—

—

XTFC020BC_

XTFR020BC_

7-1/2

15

—

XTFC025BC_

XTFR025BC_

10

20

—

XTFC032BC_

XTFR032BC_

1
1

Factory-Assembled Type F Combination Motor Controller—Frame B MMP + Frame C Contactor—
Maximum IEC Ratings 1

1

FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1

Short-Circuit
Release—
Irm (Amps)

1
1
1
1

Assembled Manual Motor Controller 2

Three-Phase
220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

10–16

224

4

7.5

9

12.5

XTFC016BC_

XTFR016BC_

16–20

280

5.5

9

12.5

15

XTFC020BC_

XTFR020BC_

20–25

350

5.5

11

15

22

XTFC025BC_

XTFR025BC_

25–32

448

7.5

15

22

30

XTFC032BC_

XTFR032BC_

Notes
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-200

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame C Contactor—
Maximum UL Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

10–16

1
1

Assembled Manual Motor Controller 2

Short-Circuit
Release—
Irm (Amps)

200V

240V

480V

224

3

5

Three-Phase
600V

Non-Reversing
Catalog Number

Reversing
Catalog Number

10

10

XTFC016DC_

XTFR016DC_

16–25

350

5

7-1/2

15

20

XTFC025DC_

XTFR025DC_

25–32

448

7-1/2

10

25

30

XTFC032DC_

XTFR032DC_

Short-Circuit
Release—
Irm (Amps)

1
1
1

Assembled Manual Motor Controller 2

Three-Phase

1

1

Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame C Contactor—
Maximum IEC Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1

1

220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

1
1

10–16

224

4

7.5

9

12.5

XTFC016DC_

XTFR016DC_

16–25

350

5.5

12.5

12.5

22

XTFC025DC_

XTFR025DC_

25–32

448

7.5

15

17.5

22

XTFC032DC_

XTFR032DC_

1
1

Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame D Contactor—
Maximum UL Ratings 1
FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Assembled Manual Motor Controller 2

Short-Circuit
Release—
Irm (Amps)

200V

240V

480V

32–40

560

10

15

40–50

700

10

50–58

812

15

55–65

882

15

Three-Phase
600V

Non-Reversing
Catalog Number

Reversing
Catalog Number

30

30

XTFC040DD_

XTFR040DD_

15

30

—

XTFC050DD_

XTFR050DD_

15

40

—

XTFC058DD_

XTFR058DD_

15

40

—

XTFC063DD_

XTFR063DD_

1
1
1
1
1

Notes
1 Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
2 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.

1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-201

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

FLA Adjustment
Range/Overload
Release—Ir
(Amps)

1
1

Short-Circuit
Release—
Irm (Amps)

1
1
1
1

XT IEC Power Control

Factory-Assembled Type F Combination Motor Controller—Frame D MMP + Frame D Contactor—
Maximum IEC Ratings 1

1

1

IEC Contactors and Starters

Assembled Manual Motor Controller 2

Three-Phase
220–
240V

380–
415V

500V

660–
690V

Non-Reversing
Catalog Number

Reversing
Catalog Number

32–40

560

11

20

22

30

XTFC040DD_

XTFR040DD_

40–50

700

14

25

30

45

XTFC050DD_

XTFR050DD_

50–58

812

17

30

37

55

XTFC058DD_

XTFR058DD_

55–65

882

18.5

34

37

55

XTFC063DD_

XTFR063DD_

AC and DC Coil Suffixes
Suffix Code

Coil Voltage

Suffix Code

110V 50 Hz, 120V 60 Hz

A

380V 50 Hz, 440V 60 Hz

L

110V 50 Hz, 120V 60 Hz

1

220V 50 Hz, 240V 60 Hz

B

400V 50 Hz

N

220V 50 Hz, 240V 60 Hz

230V 50 Hz

F

380V 60 Hz

P

1

24V 50/60 Hz

T

12V 50/60 Hz

24 Vdc

TD 3

1

415V 50 Hz, 480V 60 Hz

C

1

1
1
1
1
1
1
1
1
1

Coil Voltage

Coil Voltage

Suffix Code

A

380V 50 Hz, 440V 60 Hz

L

B

400V 50 Hz

N

230V 50 Hz

F

380V 60 Hz

P

R

24V 50/60 Hz

T

12V 50/60 Hz

R

42V 50 Hz, 48V 60 Hz

W

24–27 Vdc

TD 3

42V 50 Hz, 48V 60 Hz

W

48V 50 Hz

Y

415V 50 Hz, 480V 60 Hz

C

48V 50 Hz

Y

AD

3

550V 50 Hz, 600V 60 Hz

D

110–130 Vdc

AD 3

BD

3

208V 60 Hz

E

200–240 Vdc

BD 3

RD

3

190V 50 Hz, 220V 60 Hz

G

12–14 Vdc

RD 3

240V 50 Hz, 277V 60 Hz

H

48–60 Vdc

WD 3

Frame B Contactors

550V 50 Hz, 600V 60 Hz
208V 60 Hz
190V 50 Hz, 220V 60 Hz
240V 50 Hz, 277V 60 Hz

Coil Voltage

Suffix Code

Frame C and D Contactors

D
E
G
H

120 Vdc
220 Vdc
12 Vdc
48 Vdc

WD

3

Notes
The assembled manual motor controller (MMC) consists of an XTPR manual motor protector (MMP) and an XTCE contactor. For Frame B MMP +
Frame B contactor assemblies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The contactors are supported
mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For 16A and above, the assembly is mounted via a
DIN rail adapter plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection is made with electrical contact modules (XTPAXECMC,
XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD.
Service Factor (SF)—Setting Ir of current scale in dependence of load factor:
SF = 1.15 → Ir = 1 x In mot
SF = 1 → Ir = 0.9 x In mot
Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102.
1
2
3

Select combination motor controllers by full load amperes. Maximum motor ratings (kW, hp) are for reference only.
Underscore (_) indicates magnetic coil suffix required. See AC and DC coil suffixes above.
With DC operation: Integrated diode-resistor combination, coil rating 2.6W.

XTFC Manual Motor
Controller

XTFR Manual Motor
Controller

1
1
1
1
1

M
3~

M
3~

1
1
1
1
V5-T1-202

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Accessories

1

Line Side Adapters
Line side adapters are required for use with XTPR MMPs only when used as Type E self-protected
manual combination starters or as part of XTFC or XTFR Type F combination motor controllers.
Not required for group installation.

1
1

Line Side Adapters
XTPAXLSA

Description

Catalog Number

For use with Frame B MMPs (up to 32A)

XTPAXLSA

1
1
1

XTPAXLSA

For use with Frame D MMPs (up to 40A)

1

XTPAXLSAD

1
1
1

Combination Connection Kits
Combination connection kits include the necessary components to field assemble a manual motor
controller with an MMP (XTPR) and contactor (XTCE).

1

Non-Reversing Starters

XTPAXTPCB

For Use with …

Description/Composed of …

Std.
Pack 1

XTPR…B + XTCE…B

Mechanical connection element for XTPR…B and contactor

1

Main current wiring between XTPR…B and contactor in toolless plug connection

1

Cable guidance

1

1
Catalog Number
XTPAXTPCB

1
1

Use as contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm2
external diameter or four cables up to 3.5 mm2 external diameter
XTPAXTPCC and
XTPAXTPCD

XTPR…B + XTCE…C

DIN rail adapter plate

1

1

XTPAXTPCC

1
1

XTPR…D + XTCE…D

Main current wiring between XTPR and contactor

1

XTPAXTPCD

1
1
1

Reversing Starters
For Use with …
XTPAXTPCRB

Description/Composed of …

XTPR…B + XTCE…B01_ Mechanical connection element for XTPR…B and contactor

Std.
Pack 1

Catalog Number

1

XTPAXTPCRB

XTPR…B + XTCE…C

1

Reversing starter main current wiring in toolless plug connection

1

Control cables for electrical interlocking in toolless plug connection—
K1M: A1–K2M: 21, K1M: 21–K2M: A1, K1M: A2–K2M: A2

1

1

Cable guidance

1

1

Use as contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables up to 2.5 mm2
external diameter or four cables up to 3.5 mm2 external diameter.
XTPAXTPCRC

1

1

DIN rail adapter plate

1

Reversing starter main current wiring

1

XTPAXTPCRB

1
1
1
1

Note
1 Orders must be placed in multiples of package quantity listed.

Volume 5—Motor Control and Protection

1
CA08100006E—August 2012

www.eaton.com

V5-T1-203

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

XTPAXEC_

1
1

IEC Contactors and Starters
XT IEC Power Control

Electric Contact Module
For Use with …

Description/Composed of …

Std.
Pack 1

Catalog Number

XTPR…B + XTCE…C

Main current wiring between XTPR…B and contactor

5

XTPAXECMC

5

XTPAXECMD

Use only in combination with busbar adapter
XTPR…D + XTCE…D

1

Use only in combination with busbar adapter

1

DIN Rail Adapter Plates

1
1

XTPAXTPCPB

For Use with …

Description/Composed of …

Std.
Pack 1

Catalog Number

XTPAXTPCB
XTPAXTPCRB

45 mm wide adapter plate with one DIN rail

4

XTPAXTPCPB

4

XTPAXTPCRPB

55 mm wide adapter plate with two DIN rails

4

XTPAXTPCPD

Connection cams for further plates

4

1

Connection element for side-by-side positioning of further plates

1
1

Main current wiring between XTPR…D and contactor

XTPAXTPCRPB

XTPR…B + XTCE…C
XTPAXECMC

45 mm wide adapter plate with one DIN rail

1
Connection element for side-by-side positioning of further plates

1
1

XTPAXTPCPD

1

XTPAXECMD
XTPR…D + XTCE…C
XTPR…D + XTCE…D

1

For use with reversing and star-delta starters

1
1

Lateral Module

1

For Use with …
—

1

Description/Composed of …

Std.
Pack 1

Catalog Number

Can be grouped on the DIN rail adapter

10

XTPAXLM

Expansion of the mounting width by 9 mm

1
Connection Element

1
1
1

For Use with …

Description/Composed of …

Std.
Pack 1

Catalog Number

—

For connection of several DIN rail adapters

50

XTPAXCNE

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
V5-T1-204

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Technical Data and Specifications

1

XTSC Non-Reversing Manual Motor Controllers (MMC)—Component Bill of Material

1

Factory Assembled Manual Motor Protector + Contactor
Assembled Manual
Motor Controller 1

FLA Adjustment
Range/Overload
Release—Ir (Amps)

Component Catalog Numbers
Manual Motor
Protector

Combination
Connection Kit

Contactor 1

Manual Motor Protector
Auxiliary Contact

1
1

XTSC Frame B MMP + Frame B Contactor
XTSCP16BB_

0.1–0.16

XTPRP16BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSCP25BB_

0.16–0.25

XTPRP25BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

1
1

XTSCP40BB_

0.25–0.4

XTPRP40BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSCP63BB_

0.4–0.63

XTPRP63BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSC001BB_

0.63–1

XTPR001BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSC1P6BB_

1–1.6

XTPR1P6BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSC2P5BB_

1.6–2.5

XTPR2P5BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSC004BB_

2.5–4

XTPR004BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSC6P3BB_

4–6.3

XTPR6P3BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTSC010BB_

6.3–10

XTPR010BC1

XTPAXTPCB

XTCE009B10_

XTPAXFA11

XTSC012BB_

8–12

XTPR012BC1

XTPAXTPCB

XTCE012B10_

XTPAXFA11

XTSC016BB_

10–16

XTPR016BC1

XTPAXTPCB

XTCE015B10_

XTPAXFA11

1
1

1
1
1
1

XTSC Frame B MMP + Frame C Contactor
XTSC016BC_

10–16

XTPR016BC1

XTPAXTPCC

XTCE018C10_

XTPAXFA1

XTSC020BC_

16–20

XTPR020BC1

XTPAXTPCC

XTCE025C10_

XTPAXFA11

XTSC025BC_

20–25

XTPR025BC1

XTPAXTPCC

XTCE025C10_

XTPAXFA11

XTSC032BC_

25–32

XTPR032BC1

XTPAXTPCC

XTCE032C10_

XTPAXFA11

1
1

1

XTSC Frame D MMP + Frame C Contactor
XTSC016DC_

10–16

XTPR016DC1

2

XTCE018C10_

XTPAXFA1

XTSC025DC_

16–25

XTPR025DC1

2

XTCE025C10_

XTPAXFA11

XTSC032DC_

25–32

XTPR032DC1

2

XTCE032C10_

XTPAXFA11

1
1

XTSC Frame D MMP + Frame D Contactor
XTSC040DD_

32–40

XTPR040DC1

XTPAXTPCD 3

XTCE040D00_

XTPAXFA11

XTSC050DD_

40–50

XTPR050DC1

XTPAXTPCD 3

XTCE050D00_

XTPAXFA11

XTSC058DD_

50–58

XTPR058DC1

XTPAXTPCD 3

XTCE065D00_

XTPAXFA11

XTSC063DD_

55–65

XTPR063DC1

XTPAXTPCD 3

XTCE065D00_

XTPAXFA11

1
1
1

Notes
1 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.
2 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
3 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD),
Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).

1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-205

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

XTSR Reversing Manual Motor Controllers (MMC)—Component Bill of Material
Factory Assembled Manual Motor Protector + Contactor
Assembled Manual
Motor Controller 1

FLA Adjustment
Range/Overload
Release—Ir (Amps)

Component Catalog Numbers
Manual Motor
Protector

Combination
Connection Kit

Contactor 1

Manual Motor Protector
Auxiliary Contact

XTPAXFA11

XTSR Frame B MMP + Frame B Contactor

1

XTSRP16BB_

0.1–0.16

XTPBP16BC1

XTPAXTPCRB

(2) XTCE007B01_

XTSRP25BB_

0.16–0.25

XTPRP25BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTSRP40BB_

0.25–0.4

XTPRP40BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTSRP63BB_

0.4–0.63

XTPRP63BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTSR001BB_

0.63–1

XTPR001BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTSR1P6BB_

1–1.6

XTPR1P6BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTSR2P5BB_

1.6–2.5

XTPR2P5BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTSR004BB_

2.5–4

XTPR004BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTSR6P3BB_

4–6.3

XTPR6P3BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTSR010BB_

6.3–10

XTPR010BC1

XTPAXTPCRB

(2) XTCE009B01_

XTPAXFA11

XTSR012BB_

8–12

XTPR012BC1

XTPAXTPCRB

(2) XTCE012B01_

XTPAXFA11

1

1

XTSR Frame B MMP + Frame C Contactor

1

XTSR016BC_

10–16

XTPR016BC1

XTPAXTPCR

(2) XTCE018C01

XTPAXFA11

XTSR020BC_

16–20

XTPR020BC1

XTPAXTPCRC

(2) XTCE025C01_

XTPAXFA11

1

XTSR025BC_

20–25

XTPR025BC1

XTPAXTPCRC

(2) XTCE025C01_

XTPAXFA11

XTSR032BC_

25–32

XTPR032BC1

XTPAXTPCRC

(2) XTCE032C01_

XTPAXFA11

1

XTSR Frame D MMP + Frame C Contactor

1

XTSR016DC_

10–16

XTPR016DC

2

(2) XTCE018C01

XTPAXFA11

XTSR025DC_

16–25

XTPR025DC1

2

(2) XTCE025C01_

XTPAXFA11

1

XTSR032DC_

25–32

XTPR032DC1

2

(2) XTCE032C01_

XTPAXFA11

1

XTSR040DD_

32–40

XTPR040DC1

3

(2) XTCE040D00_

XTPAXFA11

XTSR050DD_

40–50

XTPR050DC1

3

(2) XTCE050D00_

XTPAXFA11

XTSR058DD_

50–58

XTPR058DC1

3

(2) XTCE065D00_

XTPAXFA11

XTSR063DD_

55–65

XTPR063DC1

3

(2) XTCE065D00_

XTPAXFA11

1
1
1
1

XTSR Frame D MMP + Frame D Contactor

Notes
1 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.
2 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
3 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD),
Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).

1
1
1
1
1
1
1
1
1
1
V5-T1-206

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

XTFC Non-Reversing Combination Motor Controllers—Component Bill of Material

1

Factory Assembled Manual Motor Protector + Contactor + Line Side Adapter
Assembled
Combination
Motor Controller 1

FLA Adjustment Range/
Overload Release—Ir
(Amps)

Component Catalog Numbers
Line Side
Adapter

Manual Motor
Protector

Combination
Connection Kit

Contactor 1

Manual Motor Protector
Auxiliary Contact

XTFC Frame B MMP + Frame B Contactor

1
1

XTFCP16BB_

0.1–0.16

XTPAXLSA

XTPRP16BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFCP25BB_

0.16–0.25

XTPAXLSA

XTPRP25BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFCP40BB_

0.25–0.4

XTPAXLSA

XTPRP40BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFCP63BB_

0.4–0.63

XTPAXLSA

XTPRP63BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFC001BB_

0.63–1

XTPAXLS

XTPR001BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFC1P6BB_

1–1.6

XTPAXLSA

XTPR1P6BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFC2P5BB_

1.6–2.5

XTPAXLSA

XTPR2P5BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFC004BB_

2.5–4

XTPAXLSA

XTPR004BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFC6P3BB_

4–6.3

XTPAXLSA

XTPR6P3BC1

XTPAXTPCB

XTCE007B10_

XTPAXFA11

XTFC010BB_

6.3–10

XTPAXLSA

XTPR010BC1

XTPAXTPCB

XTCE009B10_

XTPAXFA11

XTFC012BB_

8–12

XTPAXLSA

XTPR012BC1

XTPAXTPCB

XTCE012B10_

XTPAXFA11

XTFC016BB_

10–16

XTPAXLSA

XTPR016BC1

XTPAXTPCB

XTCE015B10_

XTPAXFA11

1
1

1
1
1
1
1
1

XTFC Frame B MMP + Frame C Contactor
XTFC016BC_

10–16

XTPAXLSA

XTPR016BC1

XTPAXTPCC

XTCE018C10_

XTPAXFA11

XTFC020BC_

16–20

XTPAXLSA

XTPR020BC1

XTPAXTPCC

XTCE025C10_

XTPAXFA11

XTFC025BC_

20–25

XTPAXLSA

XTPR025BC1

XTPAXTPCC

XTCE025C10_

XTPAXFA11

XTFC032BC_

25–32

XTPAXLSA

XTPR032BC1

XTPAXTPCC

XTCE032C10_

XTPAXFA11

1

XTPAXLSAD

XTPR016DC1

2

XTCE018C10_

XTPAXFA11

1

1

XTFC Frame D MMP + Frame C Contactor
XTFC016DC_

10–16

XTFC025DC_

16–25

XTPAXLSAD

XTPR025DC1

2

XTCE025C10_

XTPAXFA11

XTFC032DC_

25–32

XTPAXLSAD

XTPR032DC1

2

XTCE032C10_

XTPAXFA11

1
1

XTFC Frame D MMP + Frame D Contactor
XTFC040DD_

32–40

XTPAXLSAD

XTPR040DC1

XTPAXTPCD 3

XTCE040D00_

XTPAXFA11

XTFC050DD_

40–50

XTPAXLSAD

XTPR050DC1

XTPAXTPCD 3

XTCE050D00_

XTPAXFA11

XTCE065D00_

XTPAXFA11

XTCE065D00_

XTPAXFA11

XTFC058DD_

50–58

XTPAXLSAD

XTPR058DC1

XTPAXTPCD 3

XTFC063DD_

55–65

XTPAXLSAD

XTPR063DC1

XTPAXTPCD 3

1
1
1

Notes
1 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.
2 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
3 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD),
Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).

1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-207

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

XTFR Reversing Combination Motor Controllers—Component Bill of Material
Factory Assembled Manual Motor Protector + Contactor + Line Side Adapter
Assembled Combination
Motor Controller 1

FLA Adjustment Range/
Overload Release—Ir
(Amps)

Component Catalog Numbers
Line Side
Adapter

Manual Motor
Protector

Combination
Connection Kit

Contactor 1

Manual Motor Protector
Auxiliary Contact

XTFR Frame B MMP + Frame B Contactor

1

XTFRP16BB_

0.1–0.16

XTPAXLSA

XTPRP16BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTFRP25BB_

0.16–0.25

XTPAXLSA

XTPRP25BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTFRP40BB_

0.25–0.4

XTPAXLSA

XTPRP40BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTFRP63BB_

0.4–0.63

XTPAXLSA

XTPRP63BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTFR001BB_

0.63–1

XTPAXLSA

XTPR001BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTFR1P6BB_

1–1.6

XTPAXLSA

XTPR1P6BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTFR2P5BB_

1.6–2.5

XTPAXLSA

XTPR2P5BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTFR004BB_

2.5–4

XTPAXLSA

XTPR004BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

XTFR6P3BB_

4–6.3

XTPAXLSA

XTPR6P3BC1

XTPAXTPCRB

(2) XTCE007B01_

XTPAXFA11

1

XTFR010BB_

6.3–10

XTPAXLSA

XTPR010BC

XTPAXTPCRB

(2) XTCE009B01_

XTPAXFA11

XTFR012BB_

8–12

XTPAXLSA

XTPR012BC1

XTPAXTPCRB

(2) XTCE012B01_

XTPAXFA11

1

1

XTFR Frame B MMP + Frame C Contactor

1

XTFR016BC_

10–16

XTPAXLSA

XTPR016BC1

XTPAXTPCRC

(2) XTCE018C01_

XTPAXFA11

XTFR020BC_

16–20

XTPAXLSA

XTPR020BC1

XTPAXTPCRC

(2) XTCE025C01_

XTPAXFA11

1

XTFR025BC_

20–25

XTPAXLSA

XTPR025BC1

XTPAXTPCRC

(2) XTCE025C01_

XTPAXFA11

XTFR032BC_

25–32

XTPAXLSA

XTPR032BC1

XTPAXTPCRC

(2) XTCE032C01_

XTPAXFA11

1

XTFR Frame D MMP + Frame C Contactor

1

XTFR016DC_

10–16

XTPAXLSAD

XTPR016DC1

2

(2) XTCE018C01_

XTPAXFA11

XTFR025DC_

16–25

XTPAXLSAD

XTPR025DC1

2

(2) XTCE025C01_

XTPAXFA11

1

XTFR032DC_

25–32

XTPAXLSAD

XTPR032DC1

2

(2) XTCE032C01_

XTPAXFA11

1

XTFR040DD_

32–40

XTPAXLSAD

XTPR040DC1

3

(2) XTCE040D00_

XTPAXFA11

XTFR050DD_

40–50

XTPAXLSAD

XTPR050DC1

3

(2) XTCE050D00_

XTPAXFA11

XTFR058DD_

50–58

XTPAXLSAD

XTPR058DC1

3

(2) XTCE065D00_

XTPAXFA11

XTFR063DD_

55–65

XTPAXLSAD

XTPR063DC1

3

(2) XTCE065D00_

XTPAXFA11

1
1
1
1

XTFR Frame D MMP + Frame D Contactor

Notes
1 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.
2 The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
3 The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing
link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).

1
1
1
1
1
1
1
1
1
1
V5-T1-208

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Manual Motor Controllers Short-Circuit Ratings for UL/CSA Group Installations

1

XTSC and XTSR Manual Motor Controllers (MMC)
Group Installation, UL/CSA
Assembled Controller 1
Non-Reversing

Reversing

FLA Adjustment
Range/Overload
Release—
Ir (Amps)

Short-Circuit
Release—
Irm (Amps)

Max. rms Symmetrical Short-Circuit
Ratings (kA/kA with Current Limiter)

Maximum Upstream Protective Device
(A/A with Current Limiter)

240V

480V

600V

Maximum Fuse
600V

Maximum Circuit
Breaker 600V

1
1
1

XTSC and XTSR Frame B MMP + Frame B Contactor
XTSCP16BB_

XTSRP16BB_

0.1–0.16

2.2

50

50

50

600

600

XTSCP25BB_

XTSRP25BB_

0.16–0.25

3.5

50

50

50

600

600

XTSCP40BB_

XTSRP40BB_

0.25–0.4

5.6

50

50

50

600

600

XTSCP63BB_

XTSRP63BB_

0.4–0.63

8.82

50

50

50

600

600

XTSC001BB_

XTSR001BB_

0.63–1

14

50

50

50

600

600

XTSC1P6BB_

XTSR1P6BB_

1–1.6

22.4

50

50

50

600

600

XTSC2P5BB_

XTSR2P5BB_

1.6–2.5

35

50

50

50

600

600

XTSC004BB_

XTSR004BB_

2.5–4

56

50

50

50

600

600

XTSC6P3BB_

XTSR6P3BB_

4–6.3

88.2

50

50

50

600

600

XTSC010BB_

XTSR010BB_

6.3–10

140

22

22

22

150/600

125/600

XTSC012BB_

XTSR012BB_

8–12

168

10/50

10/50

10/50

150/600

125/600

XTSC016BB_

—

10–16

224

10/50

10/50

10/50

150/600

125/600

1
1
1
1
1
1
1

XTSC and XTSR Frame B MMP + Frame C Contactor

1

XTSC016BC_

XTSR016BC_

10–16

224

10/50

10/50

10/50

150/600

125/600

XTSC020BC_

XTSR020BC_

16–20

280

10/18

10/18

10/18

150/600

125/600

XTSC025BC_

XTSR025BC_

20–25

350

10/18

10/18

10/18

150/600

125/600

XTSC032BC_

XTSR032BC_

25–32

448

5/18

5/18

5/18

150/600

125/600

1
1

1

XTSC and XTSR Frame D MMP + Frame C Contactor
XTSC016DC_

XTSR016DC_

10–16

224

50

50

10

600

600

XTSC025DC_

XTSR025DC_

16–25

350

50

50

10

600

600

XTSC032DC_

XTSR032DC_

25–32

448

50

50

10

600

600

560

50

50

10

600

600

1

XTSC and XTSR Frame D MMP + Frame D Contactor
XTSC040DD_

XTSR040DD_

32–40

XTSC050DD_

XTSR050DD_

40–50

700

50

50

10

600

600

XTSC058DD

XTSR058DD_

50–58

812

50

50

—

—

—

XTSC063DD_

XTSR063DD_

55–65

882

50

50

—

—

—

1
1
1
1

Note
1 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.

1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-209

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Combination Motor Controllers Short-Circuit Ratings for UL 508 Type F Application
XTFC and XTFR Combination Motor Controllers (CMC), UL 508 Type F
UL 508 Type F Application

1
1

Assembled Controller 1
Non-Reversing

Reversing

FLA Adjustment
Range/Overload
Release—
Ir (Amps)

Short-Circuit
Release—
Irm (Amps)

Max. rms Symmetrical Short-Circuit
Ratings (kA)

Maximum Upstream
Protective Device (A) 2

240V

Maximum Fuse
600V

480/277V

600/347V

Maximum Circuit
Breaker 600V

1

XTFC and XTFR Frame B MMP + Frame B Contactor

1

XTFCP16BB_

XTFRP16BB_

0.1–0.16

2.2

65

65

—

Not required

Not required

XTFCP25BB_

XTFRP25BB_

0.16–0.25

3.5

65

65

—

Not required

Not required

XTFCP40BB_

XTFRP40BB_

0.25–0.4

5.6

65

65

—

Not required

Not required

XTFCP63BB_

XTFRP63BB_

0.4–0.63

8.82

65

65

—

Not required

Not required

1

XTFC001BB_

XTFR001BB_

0.63–1

14

65

65

—

Not required

Not required

1

XTFC1P6BB_

XTFR1P6BB_

1–1.6

22.4

65

65

—

Not required

Not required

XTFC2P5BB_

XTFR2P5BB_

1.6–2.5

35

65

65

—

Not required

Not required

XTFC004BB_

XTFR004BB_

2.5–4

56

65

65

—

Not required

Not required

XTFC6P3BB_

XTFR6P3BB_

4–6.3

88.2

65

65

—

Not required

Not required

1

XTFC010BB_

XTFR010BB_

6.3–10

140

65

65

—

Not required

Not required

XTFC012BB_

XTFR012BB_

8–12

168

50

50

—

Not required

Not required

1

XTFC016BB_

—

10–16

224

50

50

—

Not required

Not required

1

1

1

XTFC and XTFR Frame B MMP + Frame C Contactor
XTFC016BC_

XTFR016BC_

10–16

224

18

18

—

Not required

Not required

1

XTFC020BC_

XTFR020BC_

16–20

280

18

18

—

Not required

Not required

XTFC025BC_

XTFR025BC_

20–25

350

18

18

—

Not required

Not required

1

XTFC032BC_

XTFR032BC_

25–32

448

18

18

—

Not required

Not required

1
1

XTFC and XTFR Frame D MMP + Frame C Contactor
XTFC016DC_

XTFR016DC_

10–16

224

65

65

50

Not required

Not required

XTFC025DC_

XTFR025DC_

16–25

350

65

65

50

Not required

Not required

XTFC032DC_

XTFR032DC_

25–32

448

65

65

50

Not required

Not required

1

XTFC and XTFR Frame D MMP + Frame D Contactor
XTFC040DD_

XTFR040DD_

32–40

560

65

65

50

Not required

Not required

1

XTFC050DD_

XTFR050DD_

40–50

700

65

65

—

Not required

Not required

XTFC058DD_

XTFR058DD_

50–58

812

65

65

—

Not required

Not required

XTFC063DD_

XTFR063DD_

55–65

882

65

65

—

Not required

Not required

1
1
1

Notes
1 Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-202.
2 For UL 508 Type F applications, the combination motor controller assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required.

1
1
1
1
1
1
1
1
1
V5-T1-210

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Dimensions
Approximate Dimensions in mm [in]

1

XTSC…BB_

1
32.5 [1.28]
To Terminals

1
1
1
1
1

178.5
[7.03]

1
1
1

49.7 [1.96]
To Terminals

1
1

45
[1.77]

95.7
[3.77]

1
1

XTSR…BB_
32.5 [1.28]
To Terminals

1
1
1
1
1
183.4
[7.22]

1
1
1
49.7 [1.96]
To Terminals

95.3
[3.75]

1
1

90.3
[3.55]

1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-211

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
XTSC…BC_
57.5 [2.26]
To Terminals

Mounting Holes
for M4 Screws
or #8 Screws
(4 Places)

1
1
1
1
1

228.8 235.7
[9.01] [9.28]

210.8 [8.30]
Mounting

1
1
1

86.8
[3.42]
To Terminals

1
1

9 [.35]
34
[1.34]

1
1

45.2
[1.78]

124.3
[4.89]

XTSR…BC_

1

Mounting Holes for
M4 Screws or #8 Screws
(4 Places)

1

57.5 [2.26]
To Terminals

1
1
1
1
1
1

228.8 235.4
[9.01] [9.27]

210.8 [8.30]
Mounting

1
1

86.8 [3.42]
To
Terminals

1
1

9 [.35]
34
[1.34]
45
[1.77]

1
1

79
[3.11]

1
V5-T1-212

89.6
[3.53]

124.3
[4.89]

5.3
[.21]

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

XTSC…DD_

1

196 [7.72]

Mounting Holes for
M5 Screws or #10 Screws
(4 Places)

83.4 [3.28]
To Terminals

1
1
1
1
1
1

266 [10.47]
Mounting

1

284
[11.18]

1
1
1

142.8
[5.62]
To Coil
Terminals

1
1
1

9 [.35]
158.5
[6.24]

1

55 [2.17]

1

172.1 [6.78]
To Optional Aux. Contacts

43.4 [1.71]
Mounting

1

XTFC…BB_

1

36.3 [1.43]
To Terminals

1
1
1
1
1
209.2
[8.24]

1
1
1
1

49.7 [1.96]
To Terminals

95.7 [3.77]

1

45 [1.77]

Volume 5—Motor Control and Protection

1
CA08100006E—August 2012

www.eaton.com

V5-T1-213

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]
XTFR…BB_
36.3 [1.43]
To Terminals

1
1
1
1
1
1

214.2
[8.43]

1
1
1
49.7 [1.96]
To Terminals

1
1

90.3
[3.55]

95.3
[3.75]

1
1

XTFC…BC_
34 [1.34]
Mounting

1
1
1

61.3 [2.41]
To Terminals

Mounting Holes
for M4 Screws
or #8 Screws
(4 Places)

1
1
1
1
1

266.7
[10.50]
235.7
228.8 [9.28]
[9.01]

210.8 [8.30]
Mounting

1
1
1

86.8 [3.42]
To Terminals

1
1

9 [.35]
124.3
[4.89]

1

45.2
[1.78]

1
V5-T1-214

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Approximate Dimensions in mm [in]

1

XTFR…BC_

1

61.3 [2.41]
To Terminals

1
Mounting Holes for
M4 Screws or #8 Screws
(8 Places)

1
1
1
1
266.4
[10.49]

1

235.4
[9.27]

210.8
[8.30]

1

228.8
[9.01]

1
1
86.8 [3.42]
To Terminals

1
1

9 [.35]
34 [1.34]
45 [1.77]
79 [3.11]

124.3 [4.89]

1

89.6 [3.53]

5.3 [.21]

1
1

XTFC…DD_
86 [3.39]
To Line Side
Connector

Mounting Holes for
M5 Screws or #10 Screws
(4 Places)

1
1
1
1
1
1

297
[11.69]

266 [10.47]
Mounting

1

284
[11.18]

1
1
1

142.8
[5.62]
To Coil
Terminals

1
1
1

9 [.35]
43.4 [1.71]
Mounting

158.5 [6.24]
172.1 [6.78] To Optional Aux. Contacts

Volume 5—Motor Control and Protection

55 [2.17]

CA08100006E—August 2012

www.eaton.com

1
V5-T1-215

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Contents

XT Electronic Manual Motor Protector

Description

1

Page

Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . .
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . .
Contactors and Starters . . . . . . . . . . . . . . . . . . . .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . .
C440/XT Electronic Overload Relay . . . . . . . . . . .
Manual Motor Protectors . . . . . . . . . . . . . . . . . . .
Combination Motor Controllers . . . . . . . . . . . . . . .
XT Electronic Manual Motor Protector
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1

V5-T1-3
V5-T1-18
V5-T1-35
V5-T1-128
V5-T1-141
V5-T1-157
V5-T1-193
V5-T1-217
V5-T1-218
V5-T1-220
V5-T1-226
V5-T1-228
V5-T1-229

1
1
1

XT Electronic Manual Motor Protector

1

Product Description

1
1
1
1
1
1
1
1
1

The XT Electronic Manual
Motor Protector provides the
same functionality as the XT
thermal manual motor
protector, but with an added
level of flexibility and
selectability. The XTPE
incorporates electronic
control technology to enable
more options and larger dial
setting ranges. The trip units
are interchangeable, allowing
users to exchange as needed
using the same base. The
reduced number of part
numbers decreases bill of
material complexity while
reducing inventory demands.
The XTPE electronic manual
motor protector includes the
following features:

1

●

1

●

1

●

1
1

●

●

4:1 max to min overcurrent
dial setting range
Selectable trip class (5, 10,
15, 20)
Interchangeable trip units
Three base units (12, 32
and 65A)
Common accessories with
the XTPR

Features and Benefits
Advanced Trip Unit

Standards and Certifications
●

●

In addition to the selectability,
the XTPE is also available
with an advanced trip unit
that can communicate
system data and protector
data thru SmartWire-DT.
SmartWire-DT is an
innovative cost effective
connection technology that
enables quick installation of
control wiring to the starter
through a single green cable.
When on SmartWire-DT, the
XTPE can communicate the
following:
●

Current Values
●
Maximum phase current
●
Overload warning

Diagnostics Data
●
Overload fault
●
Cause of trip
(overcurrent or short
circuit)
●
Phase loss
●
Trip via TEST
Status Messages
●
Control unit type
●
Overload setting
●
Time-lag
●
Switching status

XTPE Electronic MMP

The XTPE Electronic MMP
provides the selectability,
control, and insight options
that give panel builders and
OEMs the solutions
necessary to enhance motor
control designs while
reducing total costs.

1
1
1
1
V5-T1-216

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

●
●
●

●
●

CE approved
UL Listed File No. E36332
UL 508 group motor and
Type E
IEC/EN  60947
CSA File 012528,
Class 3211-05

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Catalog Number Selection

1

XT—Manual Motor Protector

1

XT PE 004 B CS

1
Designation
XT = XT line of IEC control

Type
PE = Electronic MMP

Overload Release
1P2 = 0.3–1.2A
004 = 1–4A
012 = 3–12A
032 = 8–32A
065 = 16–65A

MMP Frame
B = 45 mm
D = 55 mm

Trip Type
CS = Standard
CA = Advanced (SmartWire-DT)

1
1
1
1
1

XT—Combinations

XT FCE 004 B C CS A
Designation
XT = XT line of IEC control

1
A
B
F
T
TD

Type
FCE = Electronic
combination motor
controller

Overload Release
1P2 = 0.3–1.2A
004 = 1–4A
012 = 3–12A
032 = 8–32A

MMP Frame
B = 45 mm

Contactor Frame
C = 45 mm

=
=
=
=
=

Coil Voltage
110V 50 Hz, 120V 60 Hz
220V 50 Hz, 240V 60 Hz
230V 50 Hz
24V 50/60 Hz
24 Vdc

1
1
1
1

Trip Type
CS = Selectable class 5, 10, 15, 20
CA = Selectable, advanced

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-217

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

XT IEC Power Control

Product Selection
XT Electronic Manual Motor Protector
B Frame

MMP Base
IEC

1
1
1
1
1

IEC Contactors and Starters

B Frame

UL/CSA

Maximum Motor kW Ratings

Maximum Three-Phase hp Ratings

380V
400V
415V

240V

480V

600V

220V
230V
240V

3

3

7.5

10

3

5.5

5.5

5.5

5

7.5

15

20

7.5

15

15

18.5

15

15

40

40

18.5

30

37

45

55

Maximum
Amperage

200V

12
32
65

Base Unit
440V

600V
690V

500V

Type Number

Catalog Number

7.5

PKE12

XTPE012B

30

PKE32

XTPE032B

PKE65

XTPE065D

MMP Trip Units
IEC

1

UL/CSA

Maximum Motor kW Ratings
380V
400V
415V

Overload
Release Setting
Amp Range

For Use with
Base Catalog
Number

Maximum Three-Phase hp Ratings
200V

240V

480V

600V

220V
230V
240V

440V

0.3–1.2

XTPE012B

1

1

0.5

0.5

0.18

0.37

0.37

1–4

XTPE012B

0.75

0.75

2

3

0.75

1.5

1

3–12

XTPE012B

3

3

7.5

10

3

5.5

1

8–32

5

7.5

15

20

7.5

15

1

8–32

XTPE065D

7.5

7.5

20

25

7.5

15

15

18.5

30

PKE-XTUW-32

XTPEXT032D

16–65

XTPE065D

15

15

40

40

18.5

30

37

45

55

PKE-XTU-65

XTPEXT065D

1
1

1

500V

Type Number

Catalog Number

0.37

0.75

PKE-XTU-1,2

XTPEXT1P2B

1.5

2.2

3

PKE-XTU-4

XTPEXT004B

5.5

5.5

7.5

PKE-XTU-12

XTPEXT012B

15

18.5

30

PKE-XTU-32

XTPEXT032B

XTPE032B

B Frame

XTPE032B

MMP Advanced Trip Units Used with SmartWire-DT

1

IEC

1

UL/CSA

Maximum Motor kW Ratings

For Use with
Base Catalog
Number

Maximum Three-Phase hp Ratings
200V

240V

480V

600V

220V
230V
240V

380V
400V
415V

440V

0.3–1.2

XTPE012B

1

1

0.5

0.5

0.18

0.37

1–4

XTPE012B

0.75

0.75

2

3

0.75

1.5

XTPE012B

3

3

7.5

10

3

Overload
Release Setting
Amp Range

1
1

3–12

1

Trip Unit
500V

600V
690V

Type Number

0.37

0.37

0.75

PKE-XTUA-1,2

XTPEXTA1P2B

1.5

2.2

3

PKE-XTUA-4

XTPEXTA004B

5.5

5.5

5.5

7.5

PKE-XTUA-12

XTPEXTA012B

Catalog Number

XTPE032B

1
1
1

Trip Unit
600V
690V

D Frame

8–32

XTPE032B

5

7.5

15

20

7.5

15

15

18.5

30

PKE-XTUA-32

XTPEXTA032B

8–32

XTPE065D

7.5

7.5

20

25

7.5

15

15

18.5

30

PKE-XTUWA-32

XTPEXTA032D

16–65

XTPE065D

15

15

40

40

18.5

30

37

45

55

PKE-XTUA-65

XTPEXTA065D

MMP Complete Assembly
IEC

1

Overload
Release Setting
Amp Range

1

UL/CSA

Maximum Motor kW Ratings

Maximum Three-Phase hp Ratings

380V
400V
415V

200V

240V

480V

600V

220V
230V
240V

440V

500V

600V
690V

Complete Manual Motor Protector
Type Number

Catalog Number

1

1

0.5

0.5

0.18

0.37

0.37

0.37

0.75

PKE12/XTU-1,2

XTPE1P2BCS

1

0.3–1.2
1–4

0.75

0.75

2

3

0.75

1.5

1.5

2.2

3

PKE12/XTU-4

XTPE004BCS

1

3–12

3

3

7.5

10

3

5.5

5.5

5.5

7.5

PKE12/XTU-12

XTPE012BCS

1
1

8–32

5

7.5

15

20

7.5

15

15

18.5

30

PKE32/XTU-32

XTPE032BCS

8–32

7.5

7.5

20

25

7.5

15

15

18.5

30

PKE65/XTUW-32

XTPE032DCS

16–65

15

15

40

40

18.5

30

37

45

55

PKE65/XTU-65

XTPE065DCS

Note
1 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6 (A) (1).

1
V5-T1-218

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

B Frame

1.1

MMP Used with SmartWire-DT—Complete Assembly

1

IEC
UL/CSA

Maximum Motor kW Ratings

Overload
Release Setting
Amp Range

Maximum Motor hp Ratings
200V

230V

460V

575V

220V
230V
240V

380V
400V
415V

440V

0.3–1.2

1

1

0.5

0.5

0.18

0.37

1–4

0.75

0.75

2

3

0.75

3–12

3

3

7.5

10

8–32

5

7.5

15

20

Complete Manual Motor Protector
500V

600V
690V

Type Number

Catalog Number

0.37

0.37

0.75

PKE12/XTUA-1,2

XTPE1P2BCA

1.5

1.5

2.2

3

PKE12/XTUA-4

XTPE004BCA

3

5.5

5.5

5.5

7.5

PKE12/XTUA-12

XTPE012BCA

7.5

15

15

18.5

30

PKE32/XTUA-32

XTPE032BCA

1
1
1
1
1
1

UL 508 Type E XT Electronic Combination Motor Controllers—Complete Assembly Including Trip Unit

1
B Frame

B Frame Electronic MMP with C Frame Contactor

1

UL/CSA
Overload
Release Setting
Amp Range

Maximum Three-Phase hp Ratings
200V

240V

380Y/
415V

0.3–1.2

1

1

1

1

1–4

0.75

0.75

1.5

2

Maximum Single-Phase hp Ratings

480Y/
277V

600Y/
347V

Catalog Number
Standard

Catalog Number
With SmartWire-DT

1

XTFCE1P2BCCS_ 3

XTFCE1P2BCCATD 3

0.33

XTFCE004BCCS_ 4

XTFCE004BCCATD 4
XTFCE012BCCATD 4
XTFCE032BCCATD 4

115V

200V

240V

0.5

1

1

—

0.125

0.25

3–12

3

3

5

7.5

—

0.5

1

1.5

XTFCE012BCCS_ 4

3–32

5

5

10

15

—

1.5

3

3

XTFCE032BCCS_ 4

1
1
1
1
1
1

Notes
1 In this range, calculate motor rating according to rated current. Specified values to NEC 430.6 (A) (1).
2 Complete the catalog number by replacing the underscore (_) with the coil suffix from Page V5-T1-238.
3 SCCR: 14 kA, 600 Vac
4 SCCR: 18 kA, 480 Vac

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-219

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Accessories
Auxiliary Contacts
XTPAXSA_

Side-Mount Auxiliary Contacts
Contact
Configuration

1

1NO-1NC

Contact Sequence
1.13 1.21

L1 L2 L3

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTPAXSA11

5

XTPAXSA12

5

XTPAXSA21

XTPAXSA11

1
1

1.14 1.22

1NO-2NC

1

1.13 1.21 1.31

L1 L2 L3
XTPAXSA12

1

1.14 1.22 1.32

1

2NO-1NC

1.13 1.21 1.33

L1 L2 L3
XTPAXSA21

1

1.14 1.22 1.34

1

Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and
manual transformer protectors (XTPT) and can be combined with XTPAXSATR_ and
XTPAXFA_ trip indicating auxiliary contact.

1
1
1

XTPAXFA11

Front-Mount Auxiliary Contacts
Contact
Configuration

1

1NO-1NC

1

Contact Sequence
1.53 1.61

L1 L2 L3

Pkg.
Qty. 1

Screw Terminal
Catalog Number

5

XTPAXFA11

XTPAXFA11

1

1.54 1.62

1

Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual
transformer protectors (XTPT). 45 mm (XTPR…B and XTPB) or 55 mm (XTPR…D)
widths of manual motor protectors remain unchanged.

1

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
V5-T1-220

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

XTPAXSATR_

1.1

Side-Mount Trip Indicating Auxiliary Contacts
Contact
Configuration

Contact Sequence

2 x 1NO

“+” “ ”
4.43 4.13

1

Pkg.
Qty. 1

For Use
with…

Catalog Number

2

XTPE

XTPAXSATR20

1
1
1

4.44 4.14

On/Off

1

L1L2 L3
“+”
“ >”
Trip “+”

1
1

L1L2 L3
“+”
“ >”

1

2 x 1NC

“+” “ ”
4.31 4.21

2

XTPE

XTPAXSATR02

1
1

4.32 4.22

1

On/Off

1

L1L2 L3
“+”
“ >”
Trip “+”

1

L1L2 L3
“+”
“ >”

1
1

Can be fitted on the right side of manual motor protectors. Can be combined with
standard auxiliary contacts. Trip indication: A. General trip indication (overload) B.
Short-circuit trip. Local short-circuit indication by red indicator, manually resettable.

1

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-221

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

XT IEC Power Control

Additional Accessories
XTPAXSR_

1
1
1

IEC Contactors and Starters

Contact Sequence
C1

1
1

Shunt Release

Undervoltage Release

XTPAXUVR_

Pkg.
Qty. 1

Screw Terminal
Catalog Number

Pkg.
Qty. 1

Screw Terminal
Catalog Number

2

XTPAXSR24V50H

2

XTPAXUVR24V50H

2

XTPAXSR48V50H

2

XTPAXUVR24V60H

2

XTPAXSR110V50H

2

XTPAXUVR48V50H

2

XTPAXSR120V60H

2

XTPAXUVR60V50H

2

XTPAXSR208V60H

2

XTPAXUVR110V50H

2

XTPAXSR220V50H

2

XTPAXUVR120V60H

2

XTPAXSR230V50H

2

XTPAXUVR208V60H

2

XTPAXUVR220V50H

2

XTPAXUVR230V50H

Contact Sequence
D1

U

2

XTPAXSR240V50H

2

XTPAXSR240V60H

2

XTPAXSR380V50H

2

XTPAXUVR240V50H

2

XTPAXSR400V50H

2

XTPAXUVR240V60H

2

XTPAXSR415V50H

2

XTPAXUVR380V50H

2

XTPAXSR440V60H

2

XTPAXUVR400V50H

1

2

XTPAXSR480V60H

2

XTPAXUVR415V50H

2

XTPAXSR24VDC

2

XTPAXUVR440V60H

1

2

XTPAXSR48VDC

2

XTPAXUVR480V60H

2

XTPAXSR60VDC

2

XTPAXUVR600V60H

1

2

XTPAXSR110VDC

2

XTPAXSR125VDC

2

XTPAXSR220VDC

2

XTPAXSR250VDC

C2

1
1
1

1
1
1
1

D2

Can be used to trip the manual motor protector from a remote
location. Can be fitted on left side manual motor protectors.
Cannot be combined with XTPAXSR. When combined with a
circuit breaker, it can be used as emergency-stop device to
IEC/EN 60204.

Can be used to trip the manual motor protector from a remote
location. Can be fitted on the left side of manual motor
protectors. Cannot be combined with the XTPAXUVR. DC:
Intermittent operation 5 sec.

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-222

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

IP65 Rotary Handle Mechanism 123
Enclosure
Rating

Description
XTPAXRHM_

1

Pkg.
Qty. 4

Catalog Number

1

Complete Kits—Includes Handle, Shaft and Required Hardware
Rotary handle mechanism—black 5

IP65
NEMA 12
UL/CSA 4X

1

XTPEXRHMB

1

XTPEXRHMRY

Rotary handle mechanism—black—rotated 90° from vertical 5

1

XTPEXRHM90B

Rotary handle mechanism—red/yellow—rotated 90° from vertical 6

1

XTPEXRHM90RY

Rotary handle mechanism—red/yellow 6

1
1
1

Three-Phase Commoning Links 7
For Use with…
MMP with no side-mounted
auxiliaries or voltage releases

Each MMP with one auxiliary
contact or trip-indicating auxiliary
contact fitted on the right

Each MMP with an auxiliary
contact and trip-indicating
auxiliary contact mounted on
the right or a voltage release
mounted on the left.

1

Qty.
MMP

Length of
Link (mm)

Unit
Width (mm)

Pkg.
Qty. 4

Catalog Number

2

90

45

10

XTPAXCLKA2

1

3

135

45

10

XTPAXCLKA3

1

4

180

45

10

XTPAXCLKA4

1

5

225

45

10

XTPAXCLKA5

1

2

99

45 + 9

10

XTPAXCLKB2

1

3

153

45 + 9

10

XTPAXCLKB3

1

4

207

45 + 9

10

XTPAXCLKB4

1

5

261

45 + 9

10

XTPAXCLKB5

1

2

108

45 + 18

10

XTPAXCLKC2

1
1
1

For parallel power feed to several manual motor protectors on terminals
1, 3 and 5.
XTPAXUTS

XTPAXIT

1

Shroud for Unused Terminals of Three-Phase Commoning Links
For Use with…

Description

Frame B
XTPE

To cover unused terminals on three-phase
commoning link. Protected against direct
contact.

Pkg.
Qty. 4

Catalog Number

20

XTPAXUTS

1
1
1
1

Incoming Terminals for Three-Phase
Commoning Link 8
For Use with…

Pkg.
Qty. 4

Catalog Number

Frame B XTPE

5

XTPAXIT

1
1

Notes
1 Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of 100–240 mm. Carrier
with extension shaft included.
2 With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4–8 mm hasp. Can be locked in the
OFF position, if required.
3 Rotary handle mechanisms ship with door interlock disabled. See instruction publication with product for how to
enable door interlock.
4 Orders must be placed in multiples of package quantity listed.
5 For use on main switches to IEC/EN 60204.
6 For use on main switches with emergency-stop function to IEC/EN 60204.
7 Protected against accidental contact. Frame B short-circuit proof U = 690V, I = 63A. Frame B links can be combined by
e
u
rotating mounting.
8 For three-phase commoning link, protected against accidental contact, Ue = 690V, I = 63A;
u
For conductor cross-sections: 2.5–25 mm2 stranded; 2.5–16 mm2 flexible with ferrules, AWG 14-6.

Volume 5—Motor Control and Protection

CA08100006E—August 2012

1
1
1
1
1
1
www.eaton.com

V5-T1-223

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

XT IEC Power Control

Combination Connection Kits
Non-Reversing Starters

1
1

IEC Contactors and Starters

XTPAXTPCB

For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPE…B + XTCE…B

Mechanical connection element for XTPR…B and contactor

1

XTPAXTPCB

Main current wiring between XTPR…B and contactor in toolless plug connection

1

1

Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables
up to 2.5 mm2 external diameter or four cables up to 3.5 mm2 external diameter.

1
1

XTPAXTPC_

XTPR…B + XTCE…C

1

DIN rail adapter plate
Main current wiring between XTPR and contactor

1

XTPAXTPCC

1
1
1
1

Reversing Starters

1

For Use with…
XTPAXTPCRB

XTPE…B + XTCE…B01_

1
1
1

Std.
Pack 1

Catalog Number
XTPAXTPCRB

Mechanical connection element for XTPR…B and contactor

1

Reversing starter main current wiring in toolless plug connection

1

Control cables for electrical interlocking in toolless plug connection:
– K1M: A1–K2M: 21
– K1M: 21–K2M: A1
– K1M: A2–K2M: A2

1

Cable guidance

1

Use contactor auxiliary switch XTCEXFAT_. Control cable guidance: max. six cables
up to 2.5 mm2 external diameter or four cables up to 3.5 mm2 external diameter.

1
1

Description/Comprised of …

XTPAXTPCRC

XTPE…B + XTCE…C

DIN rail adapter plate

1

Reversing starter main current wiring

1

1
1
1

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
V5-T1-224

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

XTPAXTPCRC

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

XTPAXECM_

1.1

Electrical Connection Module

1

For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPE…B + XTCE…C

Main current wiring between XTPR…B and contactor

5

XTPAXECMC

1
1
1

DIN Rail Adapter Plates

XTPAXTPCPB

For Use with…

Description/Comprised of …

Std.
Pack 1

Catalog Number

XTPAXTPCB
XTPAXTPCRB

45 mm wide adapter plate with one DIN rail

4

XTPAXTPCPB

Connection element for side-by-side positioning of further plates

1
1
1
1

PKE-SWD-32

XTPE…B +
XTCE…B or C

SmartWire-DT communication link

1

PKE-SWD-32

1
1
1
1

Note
1 Orders must be placed in multiples of package quantity listed.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-225

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

XT Electronic Manual Motor Controllers
Description

1
1

Climatic proofing

1
1

XT IEC Power Control

Technical Data and Specifications

General

1

IEC Contactors and Starters

Specification

XTPE012B

Standards and regulations

XTPE032B

XTPE065D

IEC/EN 60947-4-1, VDE 0600, UL 508, CSA C 22.2 No. 14
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Ambient temperature
Storage

–40° to 80°C

–40° to 80°C

–40° to 80°C

Open

–25° to 55°C

–25° to 55°C

–25° to 55°C

Enclosed

–25° to 40°C

–25° to 40°C

–25° to 40°C

Any

Any

Any

Device

IP20

IP20

IP20

Terminals

IP00

IP00

IP00

Direction of incoming supply

1

Degree of protection

1

Touch protection
Mechanical shock resistance half-sinusoidal shock,
10 ms to IEC 60068-2-27

25g

25g

25g

Altitude

Max. 2000m

Max. 2000m

Max. 2000m

1
1

Conductor Cross-Sections
1 x (1–6) mm2

1 x (1–6) mm2

1 x (0.75–16) mm2

1

2 x (1–6) mm2

2 x (1–6) mm2

2 x (0.75–16) mm2

1

Stranded with ferrule 1 x (1–6) mm2
to DIN 46228
2 x (1–6) mm2

1 x (1–6) mm2

1 x (0.75–35) mm2

2 x (1–6) mm2

2 x (0.75–25) mm2

Solid or stranded

18–10 AWG

18–10 AWG

14–2 AWG

1

Screw terminals

Solid

Screw Terminal Tightening Torque

1

Main conductor

1.7 Nm

1.7 Nm

3.3 Nm

Auxiliary conductor

1 Nm

1 Nm

1 Nm

1

Main Circuit

1

6,000 Vac

6,000 Vac

6,000 Vac

Overvoltage category/pollution degree

III/3

III/3

III/3

690V

690V
65A

1
1
1

Rated impulse withstand voltage

Ump

Rated operational voltage

Ue

690V

Rated uninterrupted current = rated output current

Iu = Ie

12A

32A

Rated frequency

40–60 Hz

40–60 Hz

40–60 Hz

Current heating losses (three-pole at operating
temperature)

6W

6W

6W
0.05 x 106

Lifespan, mechanical

Operations

0.05 x 106

0.05 x 106

1

Lifespan, electrical (AC-3 at 400V)

Operations

0.05 x 106

0.05 x 106

0.05 x 106

Maximum operating frequency

Operations/h

60

60

60

1

Short-Circuit Rating

1

AC-3 up to 690V

12A

32A

65A

Trip Unit

Motor switching capacity AC

1

Temperature compensation to IEC/EN 60947, VDE 0660

–5° to 40°C

–5° to 40°C

–5° to 40°C

Operating range

–25° to 55°C

–25° to 55°C

–25° to 55°C

1

Temperature compensation residual error for T >40°C

<0.1%/K

<0.1%/K

<0.1%/K

Overload release setting range

1

0.25–1 xlu

0.25–1 xlu

0.25–1 xlu

Fixed short-circuit trip setting

12 x lr (trip unit),14 x lu (base)

12 x lr (trip unit),14 x lu (base)

12 x lr (trip unit),14 x lu (base)

Short circuit release tolerance

±20%

±20%

±20%

Phase failure sensitivity

Yes

Yes

Yes

1
1
1
1

V5-T1-226

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Trip Characteristics

1

XT Electronic Manual Motor Controllers

1
XTPE …

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-227

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

Dimensions

1

XT Electronic MMP—B Frame

1

Approximate Dimensions in Inches (mm)
XT Electronic MMP—D Frame
4.65 (118.0)

1.77
(45.0)

3.79 (96.2)

1

1.28
(32.5)

1

3.98
(101.0)

6.30
(160.0)

1
1

0.57
(14.5)

4.72 (120.0)

1
1
1
1

1.38
(35.0)

1

2.17
(55.0)

XT Electronic CMC With C Frame Contactor
5.71 (145.0)

1

4.77 (121.2)
Line Side
Adapter

1

3.66 (92.9)
To Line
Side Adapter

1
1
1

9.01
(228.8)

1
1

10.63
(269.9)
To Line
Side
Adapter

9.46
(240.3)

1
1
1
1
1

1.76
(44.6)
4.87 (123.8)

1

Mounting
Rail

1
1
1
1
1
V5-T1-228

2.22
(56.5)

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

0.22 (5.5)
5.00 (127.0)
6.77 (172.0)
7.36 (187.0)

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Reference Data
Type 2 Coordination . . . . . . . . . . . . . . . . . . . . . . .
Approvals for World Markets . . . . . . . . . . . . . . . .
IEC Utilization Categories . . . . . . . . . . . . . . . . . .
Motor Ratings Data . . . . . . . . . . . . . . . . . . . . . . .
Ampacities of Insulated Conductors
(Based on 2005 NEC) . . . . . . . . . . . . . . . . . . . .

1

V5-T1-230
V5-T1-239
V5-T1-242
V5-T1-245

1
1

V5-T1-249

1
1
1

Type 1 and Type 2 Coordination
What is it?
The International
Electrotechnical Commission
(IEC) developed short-circuit
performance criteria for
contactors and starters called
Type 1 coordination and Type
2 coordination. This defines
motor controller protection
levels following a short-circuit
fault. In order to achieve this
performance, the
combination of a motor
controller (contactor or
starter) and short-circuit
protective device (manual
motor protector, circuit
breaker or fuse) must meet
the following criteria as
specified by IEC 60947-4-1—
Low voltage switchgear and
controlgear—Part 4-1:
Contactors and motorstarters—Electromechanical
contactors and motorstarters:

1
Type 1 Coordination
Type 1 Coordination requires
that under short-circuit
conditions, the contactor or
starter shall cause no danger
to persons or installation and
may not be suitable for
further service without repair
and replacement of parts.

1

In this case, significant
damage is allowed to the
contactor/starter (e.g.,
contact welding, burning or
disintegration) and the
overload relay (e.g.,
component harm or heater
element burn-out).

1

Type 2 Coordination
Type 2 Coordination requires
that under short-circuit
conditions, the contactor or
starter shall cause no danger
to persons or installation and
shall be suitable for further
use. The risk of contact
welding is recognized, in
which case the manufacturer
shall indicate the measures to
be taken as regards to the
maintenance of the
equipment.

1

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-229

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Type 2 Coordination
400, xx415V Type 2 Coordination—MMC
P
(kW)

Ie
(A)

Iq
(kA)

MMP
Catalog Number

Contactor
Catalog Number 2

MMC
Catalog Number 2

0.06

0.21

50 (150) 1

XTPRP25BC1

XTCE007B10_

XTSCP25BB_

1

1

0.09

0.31

50 (150)

XTPRP40BC1

XTCE007B10_

XTSCP40BB_

0.12

0.41

50 (150) 1

XTPRP63BC1

XTCE007B10_

XTSCP63BB_

1

0.18

0.60

50 (150) 1

XTPRP63BC1

XTCE007B10_

XTSCP63BB_

0.25

0.80

50 (150) 1

XTPR001BC1

XTCE007B10_

XTSC001BB_

1

0.37

1.10

50 (150) 1

XTPR1P6BC1

XTCE007B10_

XTSC1P6BB_

0.55

1.50

50 (150) 1

XTPR1P6BC1

XTCE007B10_

XTSC1P6BB_

0.75

1.90

50 (150) 1

XTPR2P5BC1

XTCE007B10_

XTSC2P5BB_

1

1.10

2.60

50 (150) 1

XTPR004BC1

XTCE007B10_

XTSC004BB_

1.50

3.60

50 (150)

1

XTPR004BC1

XTCE007B10_

XTSC004BB_

1

2.20

5.00

50 (150) 1

XTPR6P3BC1

XTCE007B10_

XTSC6P3BB_

3.00

6.60

50 (150) 1

XTPR010BC1

XTCE018C10_

XTSC010BC_

4.00

8.50

50 (150) 1

XTPR010BC1

XTCE018C10_

XTSC010BC_

1

5.50

11.3

50

XTPR012BC1

XTCE018C10_

XTSC012BC_

7.50

16.0

50

XTPR016BC1

XTCE018C10_

XTSC016BC_

1

11.0

21.7

50

XTPR025BC1

XTCE025C10_

XTSC025BC_

15.0

29.3

50

XTPR032BC1

XTCE032C10_

XTSC032BC_

1

1

1

5.50

11.3

50

XTPR016DC1

XTCE018C10_

XTSC016DC_

7.50

16.0

50

XTPR016DC1

XTCE018C10_

XTSC016DC_

11.0

21.7

50

XTPR025DC1

XTCE025C10_

XTSC025DC_

1

15.0

29.3

50

XTPR032DC1

XTCE032C10_

XTSC032DC_

18.5

36.0

50

XTPR040DC1

XTCE040D00_

XTSC040DD_

1

22.0

41.0

50

XTPR050DC1

XTCE050D00_

XTSC050DD_

30.0

55.0

50

XTPR058DC1

XTCE065D00_

XTSC058DD_

1

34.0

63.0

50

XTPR063DC1

XTCE065D00_

XTSC063DD_

1

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.

1

1

1

2

Values in parentheses ( ) are for Type 1 Coordination.
Underscore (_) indicates magnet coil suffix required. See Page V5-T1-238.

1
1
1
1
1
1
1
1
1
1
1
V5-T1-230

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

480V Type 2 Coordination—MMC
P
(hp)

Ie
(A)

Iq
(kA)

MMP
Catalog Number

Current Limiter
Catalog Number

Contactor
Catalog Number 2

MMC
Catalog Number 2

1/2

0.24

65

XTPRP25BC1

—

XTCE007B10_

XTSCP25BB_

1/2

0.32

65

XTPRP40BC1

—

XTCE007B10_

XTSCP40BB_

1/2

0.51

65

XTPRP63BC1

—

XTCE007B10_

XTSCP63BB_

1/2

0.74

65

XTPR001BC1

—

XTCE007B10_

XTSC001BB_

1/2

0.94

65

XTPR001BC1

—

XTCE007B10_

XTSC001BB_

3/4

1.32

65

XTPR1P6BC1

—

XTCE007B10_

XTSC1P6BB_

1

1.72

65

XTPR2P5BC1

—

XTCE018C10_

XTSC2P5BC_

2

2.55

65

XTPR004BC1

—

XTCE018C10_

XTSC004BC_

2

3.10

65

XTPR004BC1

—

XTCE018C10_

XTSC004BC_

3

4.55

65 (50) 1

XTPR6P3BC1

XTPAXCL

XTCE018C10_

XTSC6P3BC_

3

6.15

65 (50)

1

XTPR6P3BC1

XTPAXCL

XTCE018C10_

XTSC6P3BC_

7-1/2

8.40

65 (50) 1

XTPR010BC1

XTPAXCL

XTCE018C10_

XTSC010BC_

7-1/2

11.0

65 (50)

1

XTPR012BC1

XTPAXCL

XTCE018C10_

XTSC012BC_

10

14.5

65 (50) 1

XTPR016BC1

XTPAXCL

XTCE018C10_

XTSC016BC_

10

20.0

65 (50) 1

XTPR020BC1

XTPAXCL

XTCE025C10_

XTSC020BC_

20

20.0

65

XTPR025DC1

—

XTCE040D00_

XTSC025DD_

25

27.0

65

XTPR032DC1

—

XTCE040D00_

XTSC032DD_

25

32.0

65

XTPR032DC1

—

XTCE040D00_

XTSC032DD_

30

37.5

65

XTPR040DC1

—

XTCE040D00_

XTSC040DD_

40

40.5

65

XTPR050DC1

—

XTCE050D00_

XTSC050DD_

40

50.5

65

XTPR058DC1

—

XTCE065D00_

XTSC058DD_

40

64.0

65

XTPR063DC1

—

XTCE065D00_

XTSC063DD_

1
1
1
1
1
1
1
1
1
1
1

P
(hp)

Ie
(A)

Iq
(kA)

MMP
Catalog Number

Current Limiter
Catalog Number

Contactor
Catalog Number 2

MMC
Catalog Number 2

1/2

0.19

50

XTPRP25BC1

—

XTCE007B10_

XTSCP25BB_

1/2

0.26

50

XTPRP40BC1

—

XTCE007B10_

XTSCP40BB_

1/2

0.41

50

XTPRP63BC1

—

XTCE007B10_

XTSCP63BB_

1/2

0.59

50

XTPRP63BC1

—

XTCE007B10_

XTSCP63BB_

1/2

0.75

50

XTPR001BC1

—

XTCE007B10_

XTSC001BB_

1

1.06

50

XTPR1P6BC1

—

XTCE007B10_

XTSC1P6BB_

1

1.38

50

XTPR1P6BC1

—

XTCE007B10_

XTSC1P6BB_

1-1/2

2.04

50

XTPR2P5BC1

—

XTCE018C10_

XTSC2P5BC_

2.48

50

XTPR2P5BC1

—

XTCE018C10_

XTSC2P5BC_

3

3.64

50

XTPR004BC1

—

XTCE018C10_

XTSC004BC_

5

4.92

50 (18) 1

XTPR6P3BC1

XTPAXCL

XTCE018C10_

XTSC6P3BC_

10

6.72

50 (18) 1

XTPR010BC1

XTPAXCL

XTCE018C10_

XTSC010BC_

10

8.60

50 (18) 1

XTPR010BC1

XTPAXCL

XTCE018C10_

XTSC010BC_

10

11.5

50 (18) 1

XTPR012BC1

XTPAXCL

XTCE018C10_

XTSC012BC_

10

16.0

50 (18) 1

XTPR016BC1

XTPAXCL

XTCE018C10_

XTSC016BC_

25

21.5

50

XTPR025DC1

—

XTCE040D00_

XTSC025DD_

30

25.5

50

XTPR032DC1

—

XTCE040D00_

XTSC032DD_

30

30.0

50

XTPR032DC1

—

XTCE040D00_

XTSC032DD_

30

37.5

50

XTPR040DC1

—

XTCE040D00_

XTSC050DD_

40

40.5

50

XTPR050DC1

—

XTCE050D00_

XTSC050DD_

40

51.0

42

XTPR058DC1

—

XTCE065D00_

XTSC058DD_

50

61.0

42

XTPR063DC1

—

XTCE065D00_

XTSC063DD_

2

1
1
1
1
1
1
1
1
1
1
1
1
1

Values in parentheses ( ) are achieved without the current limiter.
Underscore (_) indicates magnet coil suffix required. See Page V5-T1-238.

Volume 5—Motor Control and Protection

1
1

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.
1

1
1

600V Type 2 Coordination—MMC

1-1/2

1

1
CA08100006E—August 2012

www.eaton.com

V5-T1-231

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

400, 415V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect
P
(kW)

Ie
(A)

Iq
(kA)

Fuses
Class gG/gL

Contactor
Catalog Number 1

Overload Relay
Catalog Number

Assembled Starter
Catalog Number 1

0.12

0.41

100

2

XTCE007B10_

XTOBP60BC1

XTAE007B10_P60

0.18

0.60

100

2

XTCE007B10_

XTOB001BC1

XTAE007B10_001

0.25

0.80

100

4

XTCE007B10_

XTOB001BC1

XTAE007B10_001

0.37

1.10

100

4

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

0.55

1.50

100

4

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

0.75

1.90

100

6

XTCE007B10_

XTOB2P4BC1

XTAE007B10_2P4

1

1.10

2.60

100

6

XTCE007B10_

XTOB004BC1

XTAE007B10_004

1.50

3.60

100

6

XTCE007B10_

XTOB004BC1

XTAE007B10_004

1

2.20

5.00

100

10

XTCE007B10_

XTOB006BC1

XTAE007B10_006

3.00

6.60

100

16

XTCE007B10_

XTOB010BC1

XTAE007B10_010

1

4.00

8.50

100

20

XTCE009B10_

XTOB010BC1

XTAE009B10_010

5.50

11.3

100

25

XTCE018C10_

XTOB016CC1

XTAE018C10_016

7.50

16.0

100

32

XTCE018C10_

XTOB016CC1

XTAE018C10_016

1

11.0

21.7

100

40

XTCE025C10_

XTOB024CC1

XTAE032C10_024

15.0

29.3

100

63

XTCE032C10_

XTOB032CC1

XTAE032C10_032

1

18.5

36.0

100

63

XTCE040D00_

XTOB040DC1

XTAE040D00_040

1

22.0

41.0

100

80

XTCE050D00_

XTOB057DC1

XTAE065D00_057

30.0

55.0

100

100

XTCE065D00_

XTOB057DC1

XTAE065D00_057

1

37.0

68.0

100

125

XTCE080F00_

XTOB070GC1

XTAE080F00_070

45.0

81.0

100

160

XTCE095F00_

XTOB100GC1

XTAE095F00_100

1

55.0

99.0

100

200

XTCE115G00_

XTOB100GC1

XTAE115G00_100

1
1
1
1

1

1
1
1
1
1

75.0

134.0

100

200

XTCE150G00_

XTOB150GC1

XTAE150G00_150

90.0

161.0

100

250

XTCE185L22_

XTOB220LC1

XTAE185L22_220

110.0

196.0

100

315

XTCE225L22_

XTOB220LC1

XTAE225L22_220

132.0

231.0

100

400

XTCE250L22_

XTOB250LC1

XTAE250L22_250

160.0

279.0

100

400

XTCE300M22_

XTOT290C35

XTAE300M22_290

200.0

349.0

100

500

XTCE400M22_

XTOT400C35

XTAE400M22_400

250.0

437.0

100

630

XTCE500M22_

XTOT540C35

XTAE500M22_540

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.
1

1

Underscore (_) indicates magnet coil code required. See Page V5-T1-238.

1
1
1
1
1
1
1
1
1
1
V5-T1-232

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

500V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect
P
(kW)

Ie
(A)

Iq
(kA)

Fuses
Class gG/gL

Contactor
Catalog Number 1

Overload Relay
Catalog Number

Assembled Starter
Catalog Number 1

0.12

0.33

100

2

XTCE007B10_

XTOBP40BC1

XTAE007B10_P40

0.18

0.48

100

2

XTCE007B10_

XTOBP60BC1

XTAE007B10_P60

0.25

0.70

100

2

XTCE007B10_

XTOB001BC1

XTAE007B10_001

0.37

0.90

100

2

XTCE007B10_

XTOB001BC1

XTAE007B10_001

0.55

1.20

100

4

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

0.75

1.50

100

4

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

1.10

2.10

100

6

XTCE007B10_

XTOB2P4BC1

XTAE007B10_2P4

1.50

2.90

100

6

XTCE007B10_

XTOB004BC1

XTAE007B10_004

2.20

4.00

100

10

XTCE007B10_

XTOB006BC1

XTAE007B10_006

3.00

5.30

100

16

XTCE009B10_

XTOB006BC1

XTAE009B10_006

4.00

6.80

100

16

XTCE009B10_

XTOB010BC1

XTAE009B10_010

5.50

9.00

100

20

XTCE012B10_

XTOB010BC1

XTAE012B10_010

7.50

12.1

100

25

XTCE018C10_

XTOB016CC1

XTAE018C10_016

11.0

17.4

100

32

XTCE025C10_

XTOB024CC1

XTAE025C10_024

15.0

23.4

100

50

XTCE040D00_

XTOB024DC1

XTAE040D00_024

18.5

28.9

100

50

XTCE040D00_

XTOB040DC1

XTAE040D00_040

22.0

33.0

100

63

XTCE050D00_

XTOB040DC1

XTAE050D00_040

30.0

44.0

100

80

XTCE065D00_

XTOB057DC1

XTAE065D00_057

37.0

54.0

100

100

XTCE080F00_

XTOB070GC1

XTAE080F00_070

45.0

65.0

100

125

XTCE095F00_

XTOB070GC1

XTAE095F00_070

55.0

79.0

100

160

XTCE115G00_

XTOB100GC1

XTAE115G00_100

75.0

107.0

100

200

XTCE185L22_

XTOB125LC1

XTAE185L22_125

90.0

129.0

100

200

XTCE185L22_

XTOB125LC1

XTAE185L22_125

110.0

157.0

100

250

XTCE185L22_

XTOB160LC1

XTAE185L22_160

132.0

184.0

100

250

XTCE185L22_

XTOB220LC1

XTAE185L22_220

160.0

224.0

100

315

XTCE225L22_

XTOB250LC1

XTAE225L22_250

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.
1

1

Underscore (_) indicates magnet coil code required. See Page V5-T1-238.

1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-233

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

690V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect
P
(kW)

Ie
(A)

Iq
(kA)

Fuses
Class gG/gL

Contactor
Catalog Number 1

Overload Relay
Catalog Number

Assembled Starter
Catalog Number 1

0.12

0.24

100

1

XTCE007B10_

XTOBP40BC1

XTAE007B10_P40

0.18

0.35

100

2

XTCE007B10_

XTOBP40BC1

XTAE007B10_P40

0.25

0.50

100

2

XTCE007B10_

XTOBP60BC1

XTAE007B10_P60

0.37

0.70

100

2

XTCE007B10_

XTOB001BC1

XTAE007B10_001

0.55

0.90

100

4

XTCE007B10_

XTOB001BC1

XTAE007B10_001

0.75

1.10

100

4

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

1

1.10

1.50

100

4

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

1.50

2.10

100

6

XTCE007B10_

XTOB2P4BC1

XTAE007B10_2P4

1

2.20

2.90

100

10

XTCE007B10_

XTOB004BC1

XTAE007B10_004

3.00

3.80

100

10

XTCE007B10_

XTOB004BC1

XTAE007B10_004

1

4.00

4.90

100

16

XTCE009B10_

XTOB006BC1

XTAE009B10_006

5.50

6.50

100

16

XTCE012B10_

XTOB010BC1

XTAE012B10_010

7.50

8.80

100

20

XTCE018C10_

XTOB010CC1

XTAE018C10_010

1

11.0

12.6

100

25

XTCE025C10_

XTOB016CC1

XTAE025C10_016

15.0

17.0

100

32

XTCE032C10_

XTOB024CC1

XTAE032C10_024

1

18.5

20.9

100

32

XTCE040D00_

XTOB024DC1

XTAE040D00_024

1

22.0

23.8

100

50

XTCE040D00_

XTOB040DC1

XTAE040D00_040

30.0

32.0

100

63

XTCE065D00_

XTOB040DC1

XTAE065D00_040

37.0

39.0

100

80

XTCE080F00_

XTOB050GC1

XTAE080F00_050

45.0

47.0

100

80

XTCE080F00_

XTOB050GC1

XTAE080F00_050

55.0

58.0

100

100

XTCE080F00_

XTOB070GC1

XTAE080F00_070

75.0

78.0

100

160

XTCE095F00_

XTOB100GC1

XTAE095F00_100

90.0

93.0

100

160

XTCE115G00_

XTOB100GC1

XTAE115G00_100

110.0

114.0

100

200

XTCE185L22_

XTOB125LC1

XTAE185L22_125

132.0

134.0

100

250

XTCE185L22_

XTOB160LC1

XTAE185L22_160

160.0

162.0

100

250

XTCE185L22_

XTOB220LC1

XTAE185L22_220

1
1
1
1

1

1
1
1
1
1
1

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.
1

Underscore (_) indicates magnet coil code required. See Page V5-T1-238.

1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-234

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

400, 415V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Fused Disconnect
P
(kW)

Ie
(A)

Iq
(kA)

Fuses 1
Class BS88

Contactor
Catalog Number 2

Overload Relay
Catalog Number

Assembled Starter
Catalog Number 2

0.12

0.41

80

4

XTCE007B10_

XTOBP60BC1

XTAE007B10_P60

0.18

0.60

80

4

XTCE007B10_

XTOBP60BC1

XTAE007B10_P60

0.25

0.80

80

4

XTCE007B10_

XTOB001BC1

XTAE007B10_001

0.37

1.10

80

6

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

0.55

1.50

80

10

XTCE007B10_

XTOB1P6BC1

XTAE007B10_1P6

0.75

1.90

80

16

XTCE007B10_

XTOB2P4BC1

XTAE007B10_2P4

1.10

2.60

80

16

XTCE007B10_

XTOB004BC1

XTAE007B10_004

1.50

3.60

80

20

XTCE007B10_

XTOB004BC1

XTAE007B10_004

2.20

5.00

80

20

XTCE007B10_

XTOB006BC1

XTAE007B10_006

3.00

6.60

80

20

XTCE007B10_

XTOB010BC1

XTAE007B10_010

4.00

8.50

80

25

XTCE009B10_

XTOB010BC1

XTAE009B10_010

5.50

11.3

80

25

XTCE018C10_

XTOB016CC1

XTAE018C10_016

7.50

16.0

80

25

XTCE018C10_

XTOB016CC1

XTAE018C10_016

11.0

21.7

80

35 and 32M35

XTCE025C10_

XTOB024CC1

XTAE032C10_024

15.0

29.3

80

50

XTCE032C10_

XTOB032CC1

XTAE032C10_032

18.5

36.0

80

63

XTCE040D00_

XTOB040DC1

XTAE040D00_040

22.0

41.0

80

80

XTCE050D00_

XTOB057DC1

XTAE065D00_057

30.0

55.0

80

100

XTCE065D00_

XTOB065DC1

XTAE065D00_065

1
1
1
1
1
1
1
1
1
1
1
1

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.

1

1

1

2

GEC/Alstom “Red Spot.”
Underscore (_) indicates magnet coil code required. See Page V5-T1-238.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-235

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

400, 415V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Circuit Breaker
P
(kW)

Ie
(A)

Iq
(kA)

Circuit
Breaker

Contactor
Catalog Number 1

Overload Relay
Catalog Number

Assembled Starter
Catalog Number 1

0.12

0.41

15

2

2

2

2

15

2

2

2

2

15

2

2

2

2

2

2

2

0.18
0.25

0.60
0.80

0.37

1.10

15

2

0.55

1.50

15

2

2

2

2

0.75

1.90

15

2

2

2

2

1.10

2.60

15

2

2

2

2

1.50

3.60

15

2

2

2

2

15

2

2

2

2

6.60

15

2

2

2

2

XTAE018C10_010

2.20
3.00

5.00

4.00

8.50

15

HMCPE015E0C

XTCE018C10_

XTOB010CC1

5.50

11.3

15

HMCPE015E0C

XTCE018C10_

XTOB016CC1

XTAE018C10_016

7.50

16.0

15

2

2

2

2

1

11.0

21.7

15

2

2

2

2

15.0

29.3

15

2

2

2

2

1

18.5

36.0

50

2

2

2

2

1

22.0

41.0

50

HMCPE100R3C

XTCE050D00_

XTOB057DC1

XTAE050D00_057

30.0

55.0

50

HMCPE100R3C

XTCE065D00_

XTOB065DC1

XTAE065D00_065

1

37.0

68.0

80

HMCPJ250D5L

XTCE080F00_

XTOB070GC1

XTAE080F00_070

45.0

81.0

80

HMCPJ250F5L

XTCE095F00_

XTOB100GC1

XTAE095F00_100

55.0

99.0

80

HMCPJ250G5L

XTCE115G00_

XTOB125GC1

XTAE115G00_125
XTAE150G00_150

1

1
1
1
1
1
1

75.0

134.0

80

HMCPJ250J5L

XTCE150G00_

XTOB150GC1

90.0

161.0

80

HMCPJ250W5L

XTCE185L22_

XTOB220LC1

XTAE185L22_220

110.0

196.0

70

HMCPJ250W5L

XTCE225L22_

XTOB220LC1

XTAE225L22_220

132.0

231.0

70

HMCPL600R6G

XTCE300M22_

XTOT240C3S

XTAE300M22_240

160.0

279.0

70

HMCPL600X6G

XTCE300M22_

XTOT400C3S

XTAE300M22_400

200.0

349.0

70

HMCPL600P6G

XTCE400M22_

XTOT400C3S

XTAE400M22_400

250.0

430.0

70

HMCPL600M

XCE500M22_

XTOT540C3S

XTAE500M22_540

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.
1

1

2

Underscore (_) indicates magnet coil code required. See Page V5-T1-238.
Use MMP contactor combination. See Page V5-T1-230.

1
1
1
1
1
1
1
1
1
1
V5-T1-236

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

525V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Circuit Breaker
P
(kW)

Ie
(A)

Iq
(kA)

Circuit
Breaker

Contactor
Catalog Number 1

Overload Relay
Catalog Number

Assembled Starter
Catalog Number 1

0.37

1.02

50

2

2

2

2

0.55

1.22

50

2

2

2

2

2

2

2

0.75

1.66

50

2

1.10

2.22

50

2

2

2

2

2

2

2

1.50

3.16

50

2

2.20

4.25

50

2

2

2

2

3.00

5.60

50

2

2

2

2

4.00

7.50

50

2

2

2

2

5.50

9.90

50

2

2

2

2

2

2

2

7.50

14.1

50

2

11.0

19.3

50

2

2

2

2

2

2

2

15.0

23.5

50

2

18.5

27.2

50

2

2

2

2

22.0

37.0

50

2

2

2

2

30.0

45.0

50

2

2

2

2

37.0

54.0

50

HMCP100R3C

XTCE080F00_

XTOB070GC1

XTAE080F00_070

45.0

66.0

50

HMCPJ250D5L

XTCE080F00_

XTOB070GC1

XTAE080F00_070

55.0

79.0

50

HMCPJ250F5L

XTCE115G00_

XTOB100GC1

XTAE115G00_100

75.0

111.0

50

HMCPJ250J5L

XTCE115G00_

XTOB125GC1

XTAE115G00_125

90.0

130.0

50

HMCPJ250K5L

XTCE185L00_

XTOB160LC1

XTAE185L00_160

110.0

159.0

50

HMCPJ250W5L

XTCE185L00_

XTOB160LC1

XTAE185L00_160

132.0

185.0

50

HMCPL600N6G

XTCE185L22_

XTOB220LC1

XTAE185L22_220

160.0

225.0

50

HMCPL600R6G

XTCE225L22_

XTOB250LC1

XTAE225L22_250

200.0

270.0

50

HMCPL600X6G

XTCE300M22_

XTOT290C3S

XTAE300M22_290

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

480V Type 2 Coordination—Contactor and Overload Relay (Motor Starter) with Circuit Breaker
P
(hp)

Ie
(A)

Iq
(kA)

Circuit
Breaker

Contactor
Catalog Number 1

Overload Relay
Catalog Number

Assembled Starter
Catalog Number 1

50.0

65.0

65

HMCPJ250D5L

XTCE080F00_

XTOB070GC1

XTAE080F00_070

60.0

77.0

65

HMCPJ250G5L

XTCE080F00_

XTOB100GC1

XTAE080F00_100

75.0

96.0

25

HMCPJ250J5L

XTCE115G00_

XTOB125GC1

XTAE115G00_125

100.0

124.0

50

HMCPJ250K5L

XTCE185L22_

XTOB160LC1

XTAE185L22_160

125.0

156.0

50

HMCPJ250W5L

XTCE185L22_

XTOB160LC1

XTAE185L22_160

150.0

180.0

25

HMCPL600N6G

XTCE225L22_

XTOB220LC1

XTAE225L22_220

200.0

240.0

50

HMCPL600N

XTCE300M22_

XTOB240C3S

XTAE300M22_240

250.0

290.0

50

HMCPL600R

XTCE300M22_

XTOB290C3S

XTAE300M22_290

300.0

361.0

50

HMCPL600Y

XTCE400M22_

XTOB400C3S

XTAE400M22_400

350.0

414.0

50

HMCPL600M

XTCE500M22_

XTOB540C3S

XTAE500M22_540

1
1
1
1
1
1
1

Notes
See Page V5-T1-238 for more information on wye-delta (star delta) applications.
1
2

1

Underscore (_) indicates magnet coil code required. See Page V5-T1-238.
Use MMP contactor combination.

1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-237

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

400, 415V Type 2 Coordination—Contactor with
Circuit Breaker 1

480V Type 2 Coordination—Contactor with
Circuit Breaker 1

P
(kW)

Ie
(A)

Iq
(kA)

Circuit
Breaker—MCP

Contactor
Catalog Number 2

P
(hp)

Ie
(A)

Iq
(kA)

Circuit
Breaker—MCP

Contactor
Catalog Number 2

1.50

3.60

50

HMCPE015E0C

XTCE018C10_

50.0

65.0

65

HMCPJ250G5L

XTCE080F00_

2.20

5.00

50

HMCPE015E0C

XTCE018C10_

60.0

77.0

65

HMCPJ250G5L

XTCE080F00_

1

3.00

6.60

50

HMCPE015E0C

XTCE018C10_

150.0

180.0

50

HMCPL600N

XTCE300M00_

4.00

8.50

50

HMCPE015E0C

XTCE018C10_

200.0

240.0

50

HMCPL600N

XTCE300M22__

1

5.50

11.3

50

HMCPE015E0C

XTCE018C10_

250.0

300.0

50

HMCPL600R

XTCE300M22_

7.50

16.0

50

HMCPE015E0C

XTCE018C10_

300.0

361.0

50

HMCPL600Y

XTCE400M00_

1

11.0

21.7

50

HMCPE100R3C

XTCE040D00_

350.0

414.0

50

HMCPL600M

XTCE500M00_

15.0

29.3

50

HMCPE100R3C

XTCE040D00_

18.5

36.0

50

HMCPE100R3C

XTCE040D00_

22.0

41.0

50

HMCPE100R3C

XTCE050D00_

30.0

55.0

50

HMCPE100R3C

XTCE065D00_

1

37.0

68.0

80

HMCPJ250D5L

XTCE080F00_

45.0

81.0

80

HMCPJ250F5L

XTCE095F00_

1

55.0

99.0

80

HMCPJ250G5L

XTCE115G00_

75.0

134.0

80

HMCPJ250J5L

XTCE150G00_

1

90.0

161.0

80

HMCPJ250W5L

XTCE185L22_

110.0

196.0

80

HMCPJ250W5L

XTCE225L22_

132.0

231.0

70

HMCPL600R

XTCE300M22_

160.0

279.0

70

HMCPL600X

XTCE300M22_

200.0

350.0

70

HMCPL600P

XTCE400M22_

250.0

430.0

70

HMCPL600M

XTCE500M22_

1
1

1
1

1
1
1
1

Magnet Coil Suffix

1

Frames A–B
Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

Coil Voltage

Suffix Code

1

110V 50 Hz, 120V 60 Hz

A

110V 50 Hz, 120V 60 Hz

A

100–120V 50/60 Hz

A

110–250V 40–60 Hz/DC

A

220V 50 Hz, 240V 60 Hz

B

220V 50 Hz, 240V 60 Hz

B

190–240V 50/60 Hz

B

250–500V 40–60 Hz/DC

C

230V 50 Hz

F

230V 50 Hz

F

24V 50/60 Hz

T

48–110V 40–60 Hz/DC

Y3

24–48 Vdc

TD 3

1

Frames C–F

T

24V 50/60 Hz

Frame G

1

24V 50/60 Hz

T

24 Vdc

TD

24–27 Vdc

TD

1

415V 50 Hz, 480V 60 Hz

C

415V 50 Hz, 480V 60 Hz

C

550V 50 Hz, 600V 60 Hz

D

550V 50 Hz, 600V 60 Hz

1

208V 60 Hz

E

190V 50 Hz, 220V 60 Hz

Frames L–M

3

24–27 Vdc

TD

480–500V 50/60 Hz

C

380–440V 50/60 Hz

L

D

42–48V 50/60 Hz

W

208V 60 Hz

E

110–130 Vdc

AD 3

G

190V 50 Hz, 220V 60 Hz

G

200–240 Vdc

BD 3

240V 50 Hz, 277V 60 Hz

H

240V 50 Hz, 277V 60 Hz

H

48–60 Vdc

WD 3

380V 50 Hz, 440V 60 Hz

L

380V 50 Hz, 440V 60 Hz

L

400V 50 Hz

N

400V 50 Hz

N

1

380V 60 Hz

P

380V 60 Hz

P

12V 50/60 Hz

R

12V 50/60 Hz

R

1

24V 50 Hz

U

24V 50 Hz

U

42V 50 Hz, 48V 60 Hz

W

42V 50 Hz, 48V 60 Hz

W

1

48V 50 Hz

Y

48V 50 Hz

Y

120 Vdc

AD 3

110–130 Vdc

AD 3

220 Vdc

BD 3

200–240 Vdc

BD 3

12 Vdc

RD 3

12–14 Vdc

RD 3

48 Vdc

WD 3

48–60 Vdc

WD 3

1
1

1
1

3

1
1
V5-T1-238

Volume 5—Motor Control and Protection

3

Wye-Delta (Star-Delta) Applications
If Type 2 Coordination is
required when using wyedelta starters, the full voltage
(direct on-line) test data that
is included in this document
is valid. To ensure proper

protection, the K1M (main),
K3M (star) and K5M (delta)
contactors must all be the
same size (amperage). For
wye-delta starter kits, please
see Page V5-T1-55.

Notes
1 For use with magnetic sensing means to monitor motor current.
2 Underscore (_) indicates magnet coil code required. See magnet coil suffix tables on
this page.
3 With DC operation: integrated diode-resistor combination, coil rating 2.6W.

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Approvals for World Markets
Overview
The XT line of products is
approved for use throughout
the world, including the USA
and Canada. As such, they
can be used without
restriction as devices for
world markets.
The majority of countries
permit the import of devices
on the manufacturer’s
undertaking that they have
been constructed in
accordance with the pertinent
specifications. In the USA and
Canada, however, there is a
legal obligation to obtain
official approval. In these
countries, devices and
enclosures—sometimes
even complete control
systems—are tested and
approved by independent
bodies.
In Europe, there also used to
be a legal obligation to obtain
official approval for lowvoltage switchgear and
controlgear. For industrial
control gear, this legal
obligation has now been
abolished, provided the
devices have been
manufactured and tested in
accordance with harmonized
European standards (such as
IEC/EN 60947). There is then
no longer a requirement for
them to carry their country’s
own approval mark.

1
Since January 1997, all
devices must conform to the
European Low-Voltage
Directive and, where
intended for sale within the
European Union, must carry
the CE mark.
Europe
Conformité
Européen
(CE)
This mark denotes that the
device carrying it conforms
to all relevant requirements
and specifications. The
mandatory application of this
mark therefore enables the
unrestricted use of marked
devices within the European
economic area.
Since January 1996, all
devices sold within the
European union must comply
with the Electromagnetic
Compatibility (EMC)
Directive. XT has passed the
required tests to these
Directives and the devices
carry the CE mark,
demonstrating compliance
with the EMC Directive.
Because devices bearing the
CE mark comply with the
harmonized standards,
approval and the associated
marking is no longer required
in the following countries:

Belgium
Comité Electrotechnique Belge
Belgisch Elektrotechnisch Comité
(CEBEC)
Denmark
Danmarks
Elektriske
Materielkontrol
(DEMKO)
Finland
(FIMKO)

Recently introduced is the
mandatory approval of
electrical products for:
●
Slovakia
●
Poland
●
South Africa
●
China
●
Russia
●
Turkey
●
Argentina
Marking is partly mandatory
for these countries. The IEC
rating data is accepted as in
other European countries.

France
Union Technique
de l’Electricité
(UTE)
Netherlands
Naamloze
Vennootschap
tot Keuring van
Electrotechnische
Materialien
(KEMA)
Norway
Norges Elektriske
Materiellkontrol
(NEMKO)
Sweden
Svenska
Elektriska MaterielKontrollanstalten
(SEMKO)
Switzerland
Schweizerischer
Elektrotechischer
Verein
(SEV)

Approval is not mandatory
in the Czech Republic and
Hungary. The manufacturer’s
declaration of conformity is
sufficient here.
Romania requires that
components that are to be
used in public buildings must
be approved by the Romanian
test authority ICECON.
Russia
Devices for Russia
must bear the
appropriate
marking.

Recognition

Canada
Canadian
Standards
Association
(CSA)

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Russia
Goststandart
(GOST-R)

1

South Africa
ZA
SABS

1

Argentina

1

1
1

Devices in the USA and
Canada have UL and CSA
approval.
USA
Underwriters
Laboratories
(UL)
Listing

1

1
Selection of Devices
”Selection appropriate for
export” does not mean
merely meeting the requisite
approvals and conformity to
relevant specifications. The
meaning of the term goes a
great deal further by even
including that equipment
and installations must be
designed to a concept with
export in mind.

1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-239

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

The following are important criteria for selecting switchgear suitable
for export:

1

For motor-protective circuit
breakers
Use inherently short-circuit
proof switches capable
of controlling the highest
prospective fault levels at
the point of installation
without the need for backup protection.

1
1
1
1
1
1
1
1

●

●

1

No restrictions whatsoever
for installation
Complete independence
from the on-site protective
system
No problems getting
spare parts

1
1
1
1
1
1
1

For circuit breakers
Use types with visible
contacts, quick-make and
quick-break operation as
standard. Use current-limiting
circuit breakers for high shortcircuit levels. Selective
switches are recommended
for the selective graduation
of networks.

●

1
1
1
1

During electrification
work in areas such as
Africa and the Middle East,
an insufficient voltage
stability is—at least for a
certain time—likely in
many applications (for
example due to long spur
lines or small local
generators). The use of
devices that fulfill the
above requirements will
eliminate one of the main
failure causes related to
contactors.

Advantage:

1
1

●

●

●

Independence from local
accident prevention
regulations requiring visible
contacts and safety faults
caused by inexperienced
operating personnel.
The effects of short-circuits
are kept to a minimum.
Fuseless installations
offer greater safety and
reliability in plant operation.
In the event of a fault, only
the faulty section of the
system is isolated.

For enclosures
Use insulated enclosures
with transparent covers
(i.e., “totally insulated”
enclosures).

Advantage:

Advantage:

Advantage:
●

For contactors
Use contactors whose entire
range provides consistently
reliable operation in the event
of voltage drops (consistently
down to 80% Un should be
aimed for) and whose contact
system will not assume an
indeterminate position either
on closing or on opening in
such conditions.

●

●

Total insulation is the best
possible protective
measure from the user’s
point of view, avoiding
reliance on the possibly
doubtful skills of unknown
installation personnel.
Furthermore, protective
measures based on
earthing are often
extremely difficult, if not
impossible (in the Middle
East, for example, due to
the dryness of the ground).
Insulated enclosures
completely eliminate the
need for any additional
protection against
corrosion. The transparent
covers contribute
significantly to the correct
operation of a system,
because switchgear
operation can be
monitored even with the
doors or covers closed,
thus virtually eliminating
the possibility of these
being left open through
carelessness. The
transparent cover is an
important contribution to
safety, especially where
exports to areas of
uncertain skills are
concerned.

1
1
1
1
1
1
V5-T1-240

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

For overcurrent protective
devices
Always use circuit breakers
and motor-protective circuit
breakers. Avoid fuses as
much as possible.

Advantage:
●

The operational reliability of
a system is especially
important for export
contracts. Circuit breakers
and motor-protective circuit
breakers provide this
reliability in full measure
since they can be
immediately reclosed once
a fault has been cleared,
they disconnect all poles,
they have ideal protection
through high tripping
accuracy and they can be
used for selective
operation. Because they
have no fuses or other
consumables, they also
greatly reduce the problem
of obtaining replacement
parts. The advantages of
fuseless design for export
are especially evident in
this case. No complicated
investigation is needed to
find out which fusing
system is used in the
respective location and
which specifications have
to be followed to select the
correct fuses. Often
several different fuse
systems with widely
varying characteristics are
used side-by-side in the
same country. For the
uninitiated, it may be
almost impossible to find
the right fuse in these
circumstances. These
problems do not arise
where a circuit breaker
is used.

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

For main switches and
safety switches
Use devices with positive
contact separation and clear
switch position indication.

Advantage:
●

The mechanical coupling
of the actuating element
with the contacts ensues
that the OFF position is
indicated only when all
main contacts are
separated by the
prescribed distance and
only in this position can the
switch be padlocked. This
ensures safety when
carrying out maintenance
and repair work on the
installation or machinery.

Test Authorities

Shipping Classifications

USA
USA
UL

Germany
Germanischer Lloyd (GL)

Canada
CDN
CSA

Great Britain
Lloyd‘s Register of Shipping (LR)

Romania
RO
ICECON
Russia
RUS
GOST-R
South Africa
ZA
SABS
Slovakia
SK
SKTC

France
Bureau Veritas (BV)

Poland
PL
BBJ-SEP

Norway
Det Norske Veritas(DNV)

Turkey
TR
TSE
China
PRC
CCC

1
1
1
1
1
1
1

Russia
Russian Maritime Register of Shipping (RS)

1
1

Italy
Registro Italiano Navale (RINA)

1
1
1
1

Poland
Polski Rejestr Statkow (PRS)

1
1

Ukraine
UA
Ukrain-GOST

1
1
1
1

Approvals for North America
In the U.S., the legally
established OSHA
(Occupational Safety and
Health Act) and the NEC
(National Electrical Code)
require the use of approved
devices and systems.
In Canada, all electrical
apparatus must comply with
the CEC (Canadian Electrical
Code), which requires that all
equipment and installations
have CSA approval.

1
In addition to the normal UL
and CSA approvals, the trade
regulations originating from
the NAFTA agreements allow
the application for a joint
UL and CSA approval. The
devices then carry a logo
that is recognized in both
countries.
Some local inspectors and
end users still refuse to
accept the joint listing.

Approvals for North America
Type of Approval

Approval Mark

1
1

The device is UL- and CSA-approved as discrete device.

1
The device is CSA-approved as discrete device.

1
1

The device is UL-approved as discrete device.

1
1

The device contains UL-approved components; its approval
conditions must be maintained in use (UL Recognized). The
device is CSA-approved as discrete device.

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-241

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

1

IEC Utilization Categories

1

A combination of specified
requirements relating to the
condition in which the
switching device or fuse
fulfills its purpose and
selected to represent a
characteristic group of
real-life applications. The
specified requirements may,

1
1
1
1
1
1
1

(See also IEC/EN 60947-1; 2.1.18/IEV 441-17-19)
for example, relate to the
values of making and
breaking capacity and other
characteristic values, data
concerning associated
circuits and the applicable
conditions of use and
operational behavior.

Used in Technical Data and Formula
Code

Description

Code

Description

DF

Duty factory

Irmv

Response value of short-time delayed short-circuit release

Response value of earth-fault release

Isd

Response value of short-time delayed short-circuit release

Rated short-circuit making capacity

IT

Response value of earth-fault release
Response value of earth-fault release

IDn
Icm

1

Icn

Rated short-circuit breaking capacity

Ig

Ics

Rated service short-circuit breaking capacity

Ith

Conventional free air thermal current

1

Icu

Rated ultimate short-circuit breaking capacity

Ithe

Conventional thermal current of enclosed devices

Icw

Rated short-time withstand current

Iu

Rated uninterrupted current

Ie

Rated operational current

SNT

Transformer rating

Ik

Transformer initial short-circuit AC current

tr

Time delay of overload release response

Load monitoring response value

tT

Time delay of earth-fault release response

Rated current

tg

Time delay of earth-fault release response

INT

Transformer rated current

tv

Time delay of short-circuit release response

IPK

Rated peak withstand current

Uc

Rated actuating voltage

1

Iq

Rated conditional short-circuit current

Ue

Rated operational voltage

Ir

Overcurrent release set value

Ui

Rated insulation voltage

1

Irm

Response value of non-delayed short-circuit release

Uimp

Rated impulse withstand voltage

Ii

Response value of non-delayed short-circuit release

Uk

Transformer short-circuit voltage

Response value of fixed, non-delayed short-circuit release

Us

Rated control voltage

1
1
1
1

1

IL
In

Irmf

1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-242

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Annex A (informative)

1

Examples of Utilization Categories for Low Voltage Switchgear and Controlgear 1
Relevant IEC Product Standard

1

Non-inductive or slightly inductive loads, resistance furnaces

60947-4-1

1

AC-2

Slip-ring motors: starting, switching off

60947-4-1

AC-3

Squirrel cage motors: starting, switching off motors during running

60947-4-1

Category

Typical Application

Nature of Current—AC
AC-1

AC-4

Squirrel cage motors: starting, plugging 2, inching 3

60947-4-1

AC-5a

Switching of electric discharge lamp controls

60947-4-1

AC-5b

Switching of incandescent lamps

60947-4-1

AC-6a

Switching of transformers

60947-4-1

AC-6b

Switching of capacitor banks

60947-4-1

AC-7a

Slightly inductive loads for household appliances and similar applications

61095

AC-7b

Motor-loads for household applications

61095

AC-8a

Hermetic refrigerant compressor motor control with manual resetting of overload releases

60947-4-1

AC-8b

Hermetic refrigerant compressor motor control with automatic resetting of overload releases

60947-4-1

AC-12

Control of resistive loads and solid-state loads with isolation by optocouplers

60947-5-1

AC-12

Control of resistive loads and solid-state loads with optical isolation

60947-5-2

AC-13

Control of solid-state loads with transformer isolation

60947-5-1

AC-14

Control of small electromagnetic loads

60947-5-1

AC-15

Control of AC electromagnetic loads

60947-5-1

AC-20

Connecting and disconnecting under no-load conditions

60947-3

AC-21

Switching of resistive loads, including moderate overloads

60947-3

AC-22

Switching of mixed resistive and inductive loads, including moderate overloads

60947-3

AC-23

Switching of motor loads or other highly inductive loads

60947-3

AC-31

Non-inductive or slightly inductive loads

60947-6-1

AC-33

Motor loads or mixed loads including motors, resistive loads and up to 30% incandescent lamp loads

60947-6-1

AC-35

Electric discharge lamp loads

60947-6-1

AC-36

Incandescent lamp loads

60947-6-1

AC-40

Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive reactance

60947-6-2

AC-41

Non-inductive or slightly inductive loads, resistance furnaces

60947-6-2

AC-42

Slip-ring motors: starting, switching off

60947-6-2

AC-43

Squirrel cage motors: starting, switching off motors during running

60947-6-2

AC-44

Squirrel cage motors: starting, plugging 2, inching 3

60947-6-2

AC-45a

Switching of electric discharge lamp controls

60947-6-2

AC-45b

Switching of incandescent lamps

60947-6-2

AC-51

Non-inductive or slightly inductive loads, resistance furnaces

60947-4-3

AC-52a

Control of slip ring motor stators: 8 h duty with on-load currents for start, acceleration, run

60947-4-2

AC-52b

Control of slip ring motor stators: intermittent duty

60947-4-2

AC-53a

Control of squirrel cage motors: 8 h duty with on-load currents for start, acceleration, run

60947-4-2

AC-53b

Control of squirrel cage motors: intermittent duty

60947-4-2

AC-55a

Switching of electric discharge lamp controls

60947-4-3

AC-55b

Switching of incandescent lamps

60947-4-3

AC-56a

Switching of transformers

60947-4-3

AC-56b

Switching of capacitor banks

60947-4-3

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
1 60947-1 © IEC: 2004.
2 Plugging is stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running.
3 Inching (jogging) is energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism.

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-243

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1
1
1
1

IEC Contactors and Starters
XT IEC Power Control

Examples of Utilization Categories for Low-Voltage Switchgear and Controlgear, continued 1
Category

Typical Application

Relevant IEC Product Standard

Nature of Current—AC, continued
AC-58a

Control of hermetic refrigerant compressor motors with automatic resetting of overload releases:
h duty with on-load currents for start, acceleration, run

60947-4-2

AC-58b

Control of hermetic refrigerant compressor motors with automatic resetting of overload releases: intermittent duty

60947-4-2

AC-140

Control of small electromagnetic loads with holding (closed) current <0,2 A, e.g., contactor relays

60947-5-2

Nature of Current—AC and DC
A

Protection of circuits, with no rated short-time withstand current

60947-2

1

B

Protection of circuits, with a rated short-time withstand current

60947-2

1

DC-1

Non-inductive or slightly inductive loads, resistance furnaces

60947-4-1

DC-3

Shunt-motors: starting, plugging 2, inching 3, dynamic breaking of motors

60947-4-1

1

DC-5

Series-motors: starting, plugging 2, inching 3, dynamic breaking of motors

60947-4-1

DC-6

Switching of incandescent lamps

60947-4-1

DC-12

Control of resistive loads and solid-state loads with isolation by optocouplers

60947-5-1

1

DC-12

Control of resistive loads and solid-state loads with optical isolation

60947-5-2

DC-13

Control of electromagnets

60947-5-1

1

DC-13

Control of electromagnets

60947-5-2

1

DC-14

Control of electromagnetic loads having economy resistors in circuit

60947-5-1

DC-20

Connecting and disconnecting under no-load conditions

60947-3

1

DC-21

Switching of resistive loads, including moderate overloads

60947-3

DC-22

Switching of mixed resistive and inductive loads, including moderate overloads (e.g., shunt motors)

60947-3

1

DC-23

Switching of motor loads or other highly inductive loads (e.g., series motors)

60947-3

DC-31

Resistive loads

60947-6-1

DC-33

Motor loads or mixed loads including motors

60947-6-1

DC-36

Incandescent lamp loads

60947-6-1

DC-40

Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive reactance

60947-6-2

1

DC-41

Non-inductive or slightly inductive loads, resistance furnaces

60947-6-2

DC-43

Shunt-motors: starting, plugging 2, inching 3, dynamic breaking of DC

60947-6-2

1

DC-45

Series-motors: starting, plugging 2, inching 3, dynamic breaking of DC

60947-6-2

DC-46

Switching of incandescent lamps

60947-6-2

1

1
1

1
1

Nature of Current—DC

Notes
1 60947-1 © IEC: 2004.
2 Plugging is stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running.
3 Inching (jogging) is energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism.

1
1
1
1
1
1
1
1
1
1
V5-T1-244

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Motor Ratings Data
Ampere Rating of AC and DC Motors
Ampere ratings of motors
vary somewhat, depending
upon the type of motor. The
values given below are for
drip-proof, Class B insulated
(T Frame) where available,
1.15 service factor, NEMA
Design B motors. These
values represent an average
full load motor current that
was calculated from the
motor performance data
published by several motor
manufacturers. In the case
of high torque squirrel cage
motors, the ampere ratings
will be at least 10% greater
than the values given below.

1
Caution—These average
ratings could be high or low
for a specific motor
and therefore heater coil
selection on this basis
always involves risk.
For fully reliable motor
protection, select heater
coils on the basis of full
load current rating as
shown on the motor
nameplate.

1

Ampere Ratings of Three-Phase, 60 Hz,
AC Induction Motor

1

Current in Amperes

hp

Syn.
Speed
RPM

200V

230V

380V 1

460V

575V

1/4

1800

1.09

0.95

0.55

0.48

0.38

1/3

1/2

3/4

1

1-1/2

2

3

5

7-1/2

10

1200

1.61

1.40

0.81

0.70

0.56

900

1.84

1.60

0.93

0.80

0.64

1800

1.37

1.19

0.69

0.60

0.48

1200

1.83

1.59

0.92

0.80

0.64

900

2.07

1.80

1.04

0.90

0.72

1800

1.98

1.72

0.99

0.86

0.69

1200

2.47

2.15

1.24

1.08

0.86

900

2.74

2.38

1.38

1.19

0.95

1800

2.83

2.46

1.42

1.23

0.98

1200

3.36

2.92

1.69

1.46

1.17

900

3.75

3.26

1.88

1.63

1.30

3600

3.22

2.80

1.70

1.40

1.12

1800

4.09

3.56

2.06

1.78

1.42

1200

4.32

3.76

2.28

1.88

1.50

900

4.95

4.30

2.60

2.15

1.72

3600

5.01

4.36

2.64

2.18

1.74

1800

5.59

4.86

2.94

2.43

1.94

1200

6.07

5.28

3.20

2.64

2.11

900

6.44

5.60

3.39

2.80

2.24

3600

6.44

5.60

3.39

2.80

2.24

1800

7.36

6.40

3.87

3.20

2.56

1200

7.87

6.84

4.14

3.42

2.74

900

9.09

7.90

4.77

3.95

3.16

3600

9.59

8.34

5.02

4.17

3.34

1800

10.8

9.40

5.70

4.70

3.76

1200

11.7

10.2

6.20

5.12

4.10

900

13.1

11.4

6.90

5.70

4.55

3600

15.5

13.5

8.20

6.76

5.41

1800

16.6

14.4

8.74

7.21

5.78

1200

18.2

15.8

9.59

7.91

6.32

900

18.3

15.9

9.60

7.92

6.33

3600

22.4

19.5

11.8

9.79

7.81

1800

24.7

21.5

13.0

10.7

8.55

1200

25.1

21.8

13.2

10.9

8.70

900

26.5

23.0

13.9

11.5

9.19

3600

29.2

25.4

15.4

12.7

10.1

1800

30.8

26.8

16.3

13.4

10.7

1200

32.2

28.0

16.9

14.0

11.2

900

35.1

30.5

18.5

15.2

12.2

Note
1 380V 50 Hz.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-245

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1

IEC Contactors and Starters
XT IEC Power Control

Ampere Ratings of Three-Phase, 60 Hz,
AC Induction Motor, continued

1

hp

Syn.
Speed
RPM

Current in Amperes
200V
230V

380V 1

460V

575V

75

3600

206

179

108

89.6

71.7

1800

210

183

111

91.6

73.2

16.5

1200

212

184

112

92.0

73.5

22.2

17.8

900

222

193

117

96.5

77.5

30.5

25.2

20.1

3600

266

231

140

115

92.2

31.0

25.6

20.5

1800

271

236

144

118

94.8

52.8

31.9

26.4

21.1

1200

275

239

145

120

95.6

63.1

54.9

33.2

27.4

21.9

900

290

252

153

126

101

3600

69.9

60.8

36.8

30.4

24.3

3600

—

292

176

146

116

1800

74.5

64.8

39.2

32.4

25.9

1800

—

293

177

147

117

1200

75.4

65.6

39.6

32.8

26.2

1200

—

298

180

149

119

900

77.4

67.3

40.7

33.7

27.0

900

—

305

186

153

122

3600

84.8

73.7

44.4

36.8

29.4

3600

—

343

208

171

137

1800

86.9

75.6

45.7

37.8

30.2

1800

—

348

210

174

139

1200

90.6

78.8

47.6

39.4

31.5

1200

—

350

210

174

139

900

94.1

81.8

49.5

40.9

32.7

900

—

365

211

183

146

3600

111

96.4

58.2

48.2

38.5

3600

—

452

257

226

181

1800

116

101

61.0

50.4

40.3

1800

—

458

265

229

184

1200

117

102

61.2

50.6

40.4

1200

—

460

266

230

184

900

121

105

63.2

52.2

41.7

900

—

482

279

241

193

3600

138

120

72.9

60.1

48.2

3600

—

559

338

279

223

1

1800

143

124

75.2

62.2

49.7

1800

—

568

343

284

227

1200

145

126

76.2

63.0

50.4

1200

—

573

345

287

229

1

900

150

130

78.5

65.0

52.0

900

—

600

347

300

240

3600

164

143

86.8

71.7

57.3

1800

—

678

392

339

271

1800

171

140

90.0

74.5

59.4

1200

—

684

395

342

274

1200

173

150

91.0

75.0

60.0

400

1800

—

896

518

448

358

900

177

154

93.1

77.0

61.5

500

1800

—

1110

642

555

444

hp

Syn.
Speed
RPM

Current in Amperes
200V
230V

380V 1

460V

575V

15

3600

41.9

36.4

22.0

18.2

14.5

1

1800

45.1

39.2

23.7

19.6

15.7

1200

47.6

41.4

25.0

20.7

1

900

51.2

44.5

26.9

3600

58.0

50.4

1800

58.9

51.2

1200

60.7

900

1

20

1
1
1

25

1
1

30

1
1

40

1
1

1
1

50

60

100

125

150

200

250

300

1
1
1
1
1
1
1

Single-Phase AC Motors
The following values of fullload currents are for motors
running at usual speeds and
motors with normal torque
characteristics. Motors built
for especially low speeds or
high torques may have higher
full-load currents and
multispeed motors will have
full-load current varying with
speed, in which case the
nameplate current ratings
shall be used.

The voltages listed are rated
motor voltages. The currents
listed shall be permitted for
system voltage ranges of 110
to 120 and 220 to 240V.

Full-Load Currents in Amperes, Single-Phase
Alternating-Current Motor
hp

115V

200V

208V

230V

1/6

4.4

2.5

2.4

2.2

1/4

5.8

3.3

3.2

2.9

1/3

7.2

4.1

4.0

3.6

1/2

9.8

5.6

5.4

4.9

3/4

13.8

7.9

7.6

6.9

1

16

9.2

8.8

8

1-1/2

20

11.5

11

10

2

24

13.8

13.2

12

1

3

34

19.6

18.7

17

5

56

32.2

30.8

28

1

7-1/2

80

46

44

40

10

100

57.5

55

50

1

1

Note
1 380V 50 Hz.

1
V5-T1-246

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1

IEC Contactors and Starters
XT IEC Power Control

Three-Phase AC Motors
The following values of fullload currents are typical for
motors running at speeds
usual for belted motors and
motors with normal torque
characteristics.

Motors built for low speeds
(1,200 RPM or less) or high
torques may require more
running current and multispeed motors will have fullload current varying with
speed. In these cases the
nameplate current rating shall
be used.

1

The voltages listed are rated
motor voltages. The currents
listed shall be permitted for
system voltage ranges of 110
to 120, 220 to 240, 440 to
480 and 550 to 600V.

1
1
1
1

Full-Load Current Three-Phase Alternating-Current Motors
Synchronous Type Unity Power Factor 1 Amperes

Induction Type Squirrel Cage and Wound-Rotor Amperes
hp

115V

200V

208V

230V

460V

575V

230V

460V

575V

1/2

4.4

2.5

2.4

2.2

1.1

.9

—

—

—

3/4

6.4

3.7

3.5

3.2

1.6

1.3

—

—

—

1

8.4

4.8

4.6

4.2

2.1

1.7

—

—

—

1-1/2

12.0

6.9

6.6

6.0

3.0

2.4

—

—

—

2

13.6

7.8

7.5

6.8

3.4

2.7

—

—

—

3

—

11.0

10.6

9.6

4.8

3.9

—

—

—

5

—

17.5

16.7

15.2

7.6

6.1

—

—

—

7-1/2

—

25.3

24.2

22

11

9

—

—

—

10

—

32.2

30.8

28

14

11

—

—

—

15

—

48.3

46.2

42

21

17

—

20

—

62.1

59.4

54

27

22

25

—

78.2

74.8

68

34

27

53

26

21

30

—

92

88

80

40

32

63

32

26

40

—

120

114

104

52

41

83

41

33

50

—

150

143

130

65

52

104

52

42

60

—

177

169

154

77

62

123

61

49

75

—

221

211

192

96

77

155

78

62

100

—

285

273

248

124

99

202

101

81

125

—

359

343

312

156

125

253

126

101

150

—

414

396

360

180

144

302

151

121

200

—

552

528

480

240

192

400

201

161

250

—

—

—

—

302

242

—

—

—

300

—

—

—

—

361

289

—

—

—

350

—

—

—

—

414

336

—

—

—

400

—

—

—

—

477

382

—

—

—

450

—

—

—

—

515

412

—

—

—

500

—

—

—

—

590

472

—

—

—

—

—

—

—

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Note
1 For 90 and 80 percent power factor, the above figures shall be multiplied by 1.1 and 1.25 respectively.

1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-247

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

DC Motors
The following values of fullload currents are for motors
running at base speed.

Full-Load Current in Amperes, Direct-Current Motors
Ampere Capacity of Fuses for Motors
Armature Voltage Rating 1

Recommended Values

hp

120V

240V

120V

240V

1

1/4

3.1

1.6

5

3

1/3

4.1

2.0

5

3

1

1/2

5.4

2.7

7

3

3/4

7.6

3.8

10

5

1

9.5

4.7

15

7

1

1-1/2

13.2

6.6

20

10

2

17

8.5

25

12

1

3

25

12.2

30

15

5

40

20

50

25

1

7-1/2

58

29

80

40

10

76

38

100

50

15

—

55

—

75

1

20

—

72

—

100

25

—

89

—

125

1

30

—

106

—

150

40

—

140

—

200

50

—

173

—

250

1

60

—

206

—

275

75

—

255

—

350

1

100

—

341

—

500

125

—

425

—

600

1

150

—

506

—

—

200

—

675

—

—

1

1

1

1

1

Note
1 These are average direct-current quantities.

1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-248

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

1.1

Ampacities of Insulated Conductors (Based on 2005 NEC)

1

Table 310.16. Allowable Ampacities of Insulated Conductors Rated 0–2000V, 60°–90°C [140°–194°F],
Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried),
Based on Ambient Temperature of 30°C [86°F] 1

1
1

Temperature Rating of Conductor. See NEC Table 310-13.
Copper

Aluminum or Copper-Clad Aluminum

1

60°C [140°F]

75°C [167°F]

90°C [194°F]

60°C [140°F]

75°C [167°F]

90°C [194°F]

AWG
kcmil

Types
TW†, UF 2

Types
FEPW 2, RH 2, RHW 2,
THHW 2, THW 2,
THWN 2, XHHW 2,
USE 2, ZW 2

Types
TBS, SA, SIS, FEP 2, FEPB 2, MI,
RHH 2, RHW-2, THHN 2, THHW 2,
THW-2 2, THWN-2 2, USE-2,
XHH, XHHW 2, XHHW-2, ZW-2

Types
TW 2, UF 2

Types
RH 2, RHW 2,
THHW 2, THW 2,
THWN 2, XHHW 2,
USE 2

Types
TBS, SA, SIS, THHN 2,
THHW 2, THW-2, THWN-2,
RHH 2, RHW-2, USE-2, XHH,
XHHW, XHHW-2, ZW-2

18

—

—

14

—

—

—

—

16

—

—

18

—

—

—

—

14

20✝

20✝

25†

—

—

—

—

12

25✝

25✝

30†

20†

20†

25†

12

Size

Size
AWG
kcmil

10

30

35✝

40†

25

30†

35†

10

8

40

50

55

30

40

45

8

6

55

65

75

40

50

60

6

70

85

95

55

65

75

4

70

85

100

110

65

75

85

3

85

95

115

130

75

90

100

2

95

110

130

150

85

100

115

1

110

1/0

125

150

170

100

120

135

1/0

2/0

145

175

195

115

135

150

2/0

3/0

165

200

225

130

155

175

3/0

4/0

195

230

260

150

180

205

4/0

250

215

255

290

170

205

230

250

300

240

285

320

190

230

255

300

350

260

310

350

210

250

280

350

400

280

335

380

225

270

305

400

500

320

380

430

260

310

350

500

600

355

420

475

285

340

385

600

700

385

460

520

310

375

420

700

750

400

475

535

320

385

435

750

800

410

490

555

330

395

450

800

600

355

420

475

285

340

385

600

700

385

460

520

310

375

420

700

750

400

475

535

320

385

435

750

800

410

490

555

330

395

450

800

900

435

520

585

355

425

480

900

1000

455

545

615

375

445

500

1000

1250

495

590

665

405

485

545

1250

1500

520

625

705

435

520

585

1500

1750

545

650

735

455

545

615

1750

2000

560

665

750

470

560

630

2000

Notes
1 Reprinted by permission from NFPA 70-2005. National Electrical Code®, Copyright© 2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
2 Unless otherwise specifically permitted elsewhere in this Code, the overcurrent protection for conductor types marked with an obelisk (†) shall not exceed 15A for No. 14, 20A for No. 12 and 30A
for No. 10 copper; or 15A for No. 12 and 25A for No. 10 aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-249

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

1.1
1
1

IEC Contactors and Starters
XT IEC Power Control

Table 310.16. Allowable Ampacities of Insulated Conductors Rated 0–2000V, 60°–90°C [140°–194°F],
Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried),
Based on Ambient Temperature of 30°C [86°F]—Correction Factors 1
Temperature Rating of Conductor. See NEC Table 310-13.
Copper

1

Aluminum or Copper-Clad Aluminum

60°C [140°F]

75°C [167°F]

90°C [194°F]

Types
FEPW 2, RH 2, RHW 2,
THHW 2, THW 2,
THWN 2, XHHW 2,
USE 2, ZW 2

Types
TBS, SA, SIS, FEP 2, FEPB 2, MI,
RHH 2, RHW-2, THHN 2, THHW 2,
THW-2 2, THWN-2 2, USE-2,
XHH, XHHW 2, XHHW-2, ZW-2

60°C [140°F]

75°C [167°F]

90°C [194°F]

Types
TW 2, UF 2

Types
RH 2, RHW 2,
THHW 2, THW 2,
THWN 2, XHHW 2,
USE 2

Types
TBS, SA, SIS, THHN 2,
THHW 2, THW-2, THWN-2,
RHH 2, RHW-2, USE-2, XHH,
XHHW, XHHW-2, ZW-2

1

Size

1

AWG
kcmil

Types
TW†, UF 2

1

Ambient
Temp. °C

For Ambient Temperatures Other Than 30°C [86°F], Multiply the
Allowable Ampacities Shown in the Table on Page V5-T1-249
by the Appropriate Factor Shown Below

For Ambient Temperatures Other Than 30°C [86°F], Multiply the
Allowable Ampacities Shown in the Table on Page V5-T1-249
by the Appropriate Factor Shown Below

Ambient
Temp. °F

1

21–25

1.08

1.05

1.04

1.08

1.05

1.04

70–77

26–30

1.00

1.00

1.00

1.00

1.00

1.00

78–86

1

31–35

0.91

0.94

0.96

0.91

0.94

0.96

87–95

36–40

0.82

0.88

0.91

0.82

0.88

0.91

96–104

41–45

0.71

0.82

0.87

0.71

0.82

0.87

105–113

1

46–50

0.58

0.75

0.82

0.58

0.75

0.82

114–122

51–55

0.41

0.67

0.76

0.41

0.67

0.76

123–131

1

56–60

—

0.58

0.71

—

0.58

0.71

132–140

1

61–70

—

0.33

0.58

—

0.33

0.58

141–158

71–80

—

—

0.41

—

—

0.41

159–176

1

Size
AWG
kcmil

1
1
1
1
1
1
1
1
1
1
1

Where the number of current-carrying conductors in a raceway or
cable exceeds three, the allowable ampacities shall be reduced
as shown in the following table:
Table 310.15 (B)(2)(a). Adjustment Factor for More Than
Three Current-Carrying Conductors in Raceway or Cable
Number of Current-Carrying
Conductors

Percent of Values in Tables as Adjusted
for Ambient Temperature if Necessary

4–6

80

7–9

70

10–20

50

21–30

45

31–40

40

41 and above

35

Notes
1 Reprinted by permission from NFPA 70-2005. National Electrical Code®, Copyright© 2005.
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
2 Unless otherwise specifically permitted elsewhere in this Code, the overcurrent protection
for conductor types marked with an obelisk (†) shall not exceed 15A for No. 14, 20A for No.
12 and 30A for No. 10 copper; or 15A for No. 12 and 25A for No. 10 aluminum and copperclad aluminum after any correction factors for ambient temperature and number of conductors
have been applied.

Where single conductors or multiconductor cables are stacked
or bundled longer than 24 in (610 mm) without maintaining
spacing and are not installed in raceways, the allowable
ampacity of each conductor shall be reduced as shown in
the above table.

1
1
1
1
1
1
1
V5-T1-250

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com

IEC Contactors and Starters
XT IEC Power Control

Table 310.18. Allowable Ampacities of Three Single Insulated Conductors Rated 0–2000V,
150°–250°C [302°–482°F], in Raceway or Cable Based on Ambient Air Temperature of 40°C [104°F]

1.1
1

1

Temperature Rating of Conductor. See NEC Table 310-13.
Size
AWG
kcmil

150°C [302°F]

200°C [392°F]

Type Z

Types FEP, FEPB, PFA

Copper

250°C [482°F]

150°C [302°F]

Size

1

Types PFAH, TFE

Type Z

Nickel or Nickel-Coated Copper

Aluminum or Copper-Clad Aluminum

AWG
kcmil

1
1

14

34

36

39

—

14

12

43

45

54

30

12

10

55

60

73

44

10

8

76

83

93

57

8

1
1

6

96

110

117

75

6

4

120

125

148

94

4

3

143

152

166

109

3

2

160

171

191

124

2

1

186

197

215

145

1

1/0

215

229

244

169

1/0

2/0

251

260

273

198

2/0

3/0

288

297

308

227

3/

4/0

332

346

361

260

4/0

250

—

—

—

—

250

300

—

—

—

—

300

350

—

—

—

—

350

400

—

—

—

—

400

500

—

—

—

—

500

600

—

—

—

—

600

700

—

—

—

—

700

750

—

—

—

—

750

800

—

—

—

—

800

1000

—

—

—

—

1000

1500

—

—

—

—

1500

2000

—

—

—

—

2000

1
1
1
1
1
1
1
1
1

Correction Factors
Ambient
Temp. °C

For Ambient Temperatures Other Than 40°C [104°F], Multiply the Allowable Ampacities Shown Above By the Appropriate Factor Shown Below

Ambient
Temp. °F

41–50

0.95

0.97

0.98

0.95

105–122

51–60

0.90

0.94

0.95

0.90

123–140

61–70

0.85

0.90

0.93

0.85

141–158

71–80

0.80

0.87

0.90

0.80

159–176

81–90

0.74

0.83

0.87

0.74

177–194

91–100

0.67

0.79

0.85

0.67

195–212

101–120

0.52

0.71

0.79

0.52

213–248

121–140

0.30

0.61

0.72

0.30

249–284

141–160

—

0.50

0.65

—

285–320

161–180

—

0.35

0.58

—

321–356

181–200

—

—

0.49

—

357–392

201–225

—

—

0.35

—

393–437

1
1
1
1
1
1
1
1
1
1
1
1

Note
1 Reprinted by permission from NFPA 70-2005. National Electrical Code®, Copyright© 2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

1
1
1

Volume 5—Motor Control and Protection

CA08100006E—August 2012

www.eaton.com

V5-T1-251



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Zoltun Design
Create Date                     : 2012:08:06 11:36:31-05:00
Modify Date                     : 2012:09:25 08:43:13-05:00
Subject                         : IEC Contactors and Starters
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2012:09:25 08:43:13-05:00
Producer                        : Acrobat Distiller 9.5.1 (Macintosh)
Format                          : application/pdf
Creator                         : Zoltun Design
Title                           : Volume 5 Tab 1
Description                     : IEC Contactors and Starters
Document ID                     : uuid:68d035e2-d143-784f-b3e6-b37b717079cd
Instance ID                     : uuid:65d57ef8-dd40-4e7e-a6c1-6fc91042de68
Page Count                      : 251
EXIF Metadata provided by EXIF.tools