Mohawk Cat.Inside 2006 111845 Catalog
2014-11-11
: Pdf 111845-Catalog 111845-Catalog 001473 Batch12 unilog
Open the PDF directly: View PDF .
Page Count: 72
Download | |
Open PDF In Browser | View PDF |
MOHAWK THE COMPANY From our main facility located in Leominster, MA, Mohawk controls more than 385,000 square feet of manufacturing space, employing the latest in manufacturing technology. Led by the vast experience of our engineering, manufacturing, and quality staff, we are able to monitor each step of the manufacturing process with real-time data acquisition. We combine exceptional performance that goes beyond standards compliance, enabling us to offer superior products at competitive prices. Included in this vast New England-based manufacturing space is 50,000 square feet dedicated to advanced fiber optic cable production. Our centralized control of all operations enables us to meet your specifications and your schedules, including copper and fiber composite cables. We have a long, proud history and we will continue to live up to your expectations of delivering quality products from our ISO 9001 registered manufacturing facilities. Our products make use of industry leading independent testing laboratories such as Underwriters Laboratories and Intertek ETL, assuring you both safety and performance compliance. Mohawk engineers continue to lead the industry with innovative, standards-leading products such as Augmented Category 6 GigaLAN 10 UTP and Grade 6 fiber cables. By tracking developments in the leading standards bodies which create the active technology standards, we can anticipate future cabling requirements. Customers can take advantage of this insight by specifying products that will maximize their investment in the cable plant. Open Architecture: Guaranteed Cabling Excellence Mohawk’s unique Open Architecture opens doors to a choice of system components with end-to-end interoperability. Combine Mohawk’s fiber optic cable and Category 5e, 6 or enhanced Category 6 with any TIA/EIA-568-B compliant connectivity hardware and your system will be guaranteed the highest performance from backbone to outlet. Mohawk lets you create your own unique networking solution for flexibility and dependability. All Mohawk structured cabling systems have been verified by an independent third-party testing laboratory and are warranted from 15 years up to a lifetime to meet or exceed the latest industry standards. Test data provides additional guarantees that the cabling system will support the latest applications. Open Architecture also makes sense for installers. Through Mohawk’s Accredited Contractors (MAC) program, contractors can earn the SystemMATE accreditation. Becoming a SystemMATE contractor allows them to offer Mohawk’s ChannelMATE end-to-end warranteed system when installed using any approved connectivity hardware, previously defined by the industry standards. Index ■ UTP Cables ■ Special Application Cables GigaLAN 10™ Augmented Category 6. . . . . . . . . . . . . . . 4 GigaLAN® Category 6e+ . . . . . . . . . . . . . . . . . . . . . . . . . 6 AdvanceNet® Category 6e . . . . . . . . . . . . . . . . . . . . . . . . 8 6 LAN™ Category 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 MegaLAN® Category 5E+ . . . . . . . . . . . . . . . . . . . . . . . 12 5e LAN® Category 5e . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Category 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Category 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Outside Plant Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 VersaLAN CM Indoor/Outdoor Cable . . . . . .N.E. W . . . . . . 27 Cellular Tower Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Industrial Ethernet Cables . . . . . . . . . . . . . . . . . . . . . . . . 29 Bundled Copper Cables . . . . . . . . . . . . . . . . . . . . . . . . . 30 Bundled Fiber & Copper Cables . . . . . . . . . . . . . . . . . . 31 ■ ScTP Cables AdvanceNet® Category 6 . . . . . . . . . . . . . . . . . . . . . . . . 16 MegaLAN® Category 5E+ . . . . . . . . . . . . . . . . . . . . . . . 18 5e LAN® Category 5e . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Category 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Category 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 ■ UTP & ScTP Cables High Pair Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 GigaLink™ Category 6e+ Patch Cables . . . . . . . . . . . . 24 AdvanceLink® Category 6e Patch Cables . . . . . . . . . . . 24 MegaLink™ Category 5e+ Patch Cables . . . . . . . . . . . 24 5e LAN® Category 5e Patch Cables . . . . . . . . . . . . . . . . 24 ARMM Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 1-800-422-9961 www.mohawk-cable.com Products with this logo comply with the EU-RoHS directive 2002/95/EC (Restrictions on hazardous substances) regulations. ISO 9001:2000 CERTIFIED TM ■ Fiber Optic Cables Distribution Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Ribbon Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Breakout Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Outdoor Loose Tube Cables. . . . . . . . . . . . . . . . . . . . . . 42 Indoor/Outdoor Loose Tube Cables . . . . . . . . . . . . . . . . 44 Indoor/Outdoor Plenum Cables . . . . . . . . . . . . . . . . . . . 46 Central Tube Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Micro-Loose Tube® Cables . . . . . . . . . . . . . . . . . . . . . . . 48 ArmorLite™ Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Simplex & Duplex Cables . . . . . . . . . . . . . . . . . . . . . . . . 50 Tactical Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Plug & Play Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . 53 Field Breakout Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Part Number Cross Reference . . . . . . . . . . . . . . . . . . . . 54 Fiber Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 ■ Technical Section Color Charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Insulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Installation Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Slide Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Technical Advisory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 MAC Certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Shipping Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Open Architecture Open Architecture: Guaranteed Cabling Excellence Mohawk’s Open Architecture opens doors to allow a completely flexible and warranted mix-and-match network system, without the confines of competitive dictated partnerships. Since the cable products and installation practices are warranteed through Mohawk, the channel performance is guaranteed for up to a lifetime (see chart at right). With the Open Architecture concept, designers and end-users can create their customized network from a variety of connectivity products which have been third-party verified, through Mohawk’s ChannelMate® program. Through our extensive Mohawk training, contractors can earn the SystemMATE® accreditation. Becoming a SystemMATE contractor allows them to offer Mohawk’s ChannelMATE end-to-end system warranty, installed using any approved connectivity hardware, independently verified and defined by the industry standards. Mohawk provides the right combination of cable products with many leading industry connectivity products to deliver an infrastructure that affords flexibility, expandability, and durability. With each ChannelMATE warranteed system, the end-user is provided with all test results, confirming that the installed system meets or exceeds the latest TIA/EIA568-B standard, as well as ETL and UL specifications to assure compliance for safety and performance. Mohawk is an ISO 9001 compliant facility, adhering to its quality standards. ChannelMATE guarantees that the cable and connectivity meet the specified backbone and horizontal system specifications as defined in 2 MOHAWK TIA/EIA-568-B. All parts and labor are guaranteed from 15 years up to the life of the system, depending on the channel: 15-year Warranty 5e LAN Copper Backbone 25-year Warranty Fiber Optic AdvanceNet 20-year Warranty MegaLAN 6 LAN Lifetime Warranty GigaLAN GigaLAN 10 Futureproof Tomorrow’s Network Today Emerging applications such as converging technologies (voice over IP, streaming video, etc.) and large data storage enterprises will push bandwidth to 10 Gb/s. Network designers need to plan a cabling infrastructure that will support multi-gigabit protocols today and also be scalable for tomorrow’s applications. combined with today’s ongoing development and with the backing of Belden, Mohawk is poised to significantly expand its cable product offerings and market share to exceed goals for the next half century, to become the leader in telecommunications. Mohawk’s GigaLAN 10™ cabling solution delivers 10 GbE to the desktop needed in today’s bandwidth intensive environments, found in both backbones and enterprise data centers, SANs, and MANs. With extended performance capabilities through the unique engineering of GigaLAN 10 Augmented Category 6 cable, it becomes today’s cost-effective twisted-pair solution to fiber for migration to 10 Gb/s. GigaLAN 10 meets the proposed Augmented Category 6 standards, which will become TIA/EIA568-B.2-10, to support the operation of 10GBASE-T over 100 meters. Transmission will employ full duplex (transmitting and receiving simultaneously) over all four-pairs for a data rate of 2.5 Gb/s per twisted pair and extend the frequency characterization requirements to 500 MHz. From engineering design to quality assurance, Mohawk products have exceeded all expectations for over 50 years. With their proven track record, MOHAWK 3 Augmented Category 6 UTP ™ GigaLAN 10 Tested to 750 MHz GigaLAN 10, the highest performance Augmented Category 6 cable, supports 10GBASE-T applications over a full 100-meter channel, exceeding the requirements of the current Draft of ANSI/TIA/EIA-568-B.2-10. IEEE 802.3an is looking beyond the present, specifying an operating range from 1-500 MHz. GigaLAN 10’s unique FlexWeb® combined with patented fluted jacket construction isolates the cable pairs and has outstanding pair-to-pair balance for superior headroom and reduced crosstalk. • • • • • Lifetime Warranty* Increase in power to 500 MHz due to lower insertion loss characteristics than Category 6. Improvement in NEXT and ELFEXT vs. draft Category 6A – 2 dB minimum for NEXT and 4 dB minimum for ELFEXT. Application – Support for 10 Gigabit Ethernet / 10GBASE-T / IEEE 802.3an; fully backwards compatible for 10BASE-T, 100BASE-T, and 1000BASE-T applications. Power Sum Alien Crosstalk – Power Sum Alien Crosstalk measures the impact of many aggressors on one victim • pair. It is the sum of unwanted signal coupling of crosstalk noise from the external cabling pairs into a victim pair of a cable. In the illustration (see Figure 1), a bundle of 7 cables with 6 cables around a center cable is depicted. What is being measured is the noise coupling from the pairs in the outer ring of Figure 1 cables (aggressor pairs) to the pairs in the center cable (victim pair). Each pair of the aggressor cables contributes noise to each of the pairs in the victim cable. The total impact on the victim is determined using a power summation equation. This cable and/or its manufacture are covered by US Patent Nos. 6,596,944, 6,074,503, 5,424,491, 7,135,641 and patent pending. * Warranty available with MAC and SystemMATE® programs. Electrical Characteristics STANDARDS: EXCEEDS DRAFT TIA 568-B.2-10 CAT 6A, DRAFT ISO/IEC 11801 ED. 2.1 CAT 6A & DRAFT IEC 61156-5 CAT 6A HORIZONTAL CABLE Power Sum Alien NEXT CONDUCTOR DCR: 6.6 V/100m (20.0 V/Mft) MAX DCR UNBALANCE: 3% MAX MUTUAL CAPACITANCE: 46 pF/m (14 pF/ft) NOM CAPACITANCE UNBALANCE PAIR/GROUND: 33 pF/100m (100 pF/Mft) MAX CHARACTERISTIC IMPEDANCE: 100 V 67% (10-550 MHz) INPUT IMPEDANCE: 100 V 610% (1-100 MHz) 100 V 615% (>100-350 MHz) 100 V 622% (>350 MHz) Power Sum Alien ACRF PROPAGATION DELAY SKEW: 25 ns/100m MAX NOMINAL VELOCITY OF PROPAGATION (NVP): PLENUM 72% NON-PLENUM 68% Safety listed to NEC (NFPA 70) 4 MOHAWK FPO Verified by ETL to TIA/EIA-568-B.2-10 Cable DIagram Ripcord Jacket Insulation Jacket Colors for 4-Pair Non-Plenum Conductor FlexWeb Jacket Colors for 4-Pair Plenum Jacket Color Mohawk # Jacket Color Mohawk # WHITE BLUE YELLOW GRAY M58651 M58650 M58652 M58653 WHITE BLUE YELLOW GRAY M58647 M58646 M58648 M58649 Custom colors available; please consult the factory. FREQ (MHz) INSERTION LOSS (dB/100m) NEXT (dB/100m) PS-NEXT (dB/100m) ACRF (dB/100m) PS-ACRF (dB/100m) RETURN LOSS (dB) PROP DELAY (ns/100m) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 500.0 550.0 600.0 650.0 750.0 max 1.8 2.0 3.7 5.2 5.9 7.4 8.3 9.3 10.4 14.9 19.0 24.0 27.5 31.0 34.2 37.2 40.0 45.3 47.7 50.1 52.4 56.8 min 78.0 76.3 67.3 62.8 61.3 58.2 56.8 55.3 53.9 49.4 46.3 43.4 41.8 40.3 39.1 38.1 37.3 35.8 35.2 34.6 34.1 33.2 min 76.0 74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 41.4 39.8 38.3 37.1 36.1 35.3 33.8 33.2 32.6 32.1 31.2 min 71.8 59.8 53.7 51.8 47.7 45.8 43.8 41.9 35.9 31.8 28.0 25.8 23.8 22.3 20.9 19.8 17.8 - min 69.8 57.8 51.7 49.8 45.7 43.8 41.8 39.9 33.9 29.8 26.0 23.8 21.8 20.3 18.9 17.8 15.8 - min 20.0 24.2 26.3 27.0 27.0 27.0 26.5 25.9 24.2 23.1 22.0 21.4 20.9 20.4 20.1 19.7 19.2 19.0 18.8 18.6 18.2 max 570.0 552.0 546.7 545.4 543.0 542.0 541.2 540.4 538.6 537.6 536.9 536.5 536.3 536.1 535.9 535.8 535.6 - ALIEN CROSSTALK PS-ANEXT PS-AACRF (dB/100m) (dB/100m) min 67.0 67.0 67.0 67.0 67.0 67.0 67.0 67.0 65.6 62.5 59.6 58.0 56.5 55.3 54.3 53.5 52.0 - min 67.0 66.2 60.1 58.2 54.1 52.2 50.2 48.3 42.3 38.2 34.4 32.2 30.2 28.7 27.3 26.2 24.2 - Values above 500 MHz are for engineering information only. Jacket Type Diameter inch mm Mohawk Part No. Cable Type Dielectric Type Weight lbs/M' kg/km Listings M58651 Non-Plenum 4 PAIR 23 AWG UTP Thermoplastic White PVC .320 8.13 49 73 C(UL)US CMR M58647 Plenum 4 PAIR 23 AWG UTP FEP White ThermoPlen®* .320 8.13 50 74 C(UL)US CMP *Plenum rated Thermoplastic. For pair colors see chart A on page 59. Packaging Options Put-Up Package Number Per Pallet Pallet Size 1000 Ft. 18” Reels 15 44” x 44” MOHAWK 5 Category 6e+ UTP GigaLAN ® Tested to 750 MHz GigaLAN is the one of the highest performance unshielded twisted pair (UTP) cable available today. The FlexWeb® construction isolates the pairs throughout the length of the cable, while providing an installer-friendly cable. The unique GigaLAN FlexWeb construction isolates the cable pairs and enhances the pair-to-pair balance for superior crosstalk, LCL and LCTL performance. Compact cable design meets the diameter requirements specified in TIA/EIA-568-B, providing flexibility and ease of installation. Electrical performance is ETL verified to TIA/EIA 568-B.2-1 Category 6. • • • • Tested to 750 MHz – with verified stability. Lifetime Warranty* 34% increase in power due to lower insertion loss characteristics at 100 MHz and greater than 50% at 250 MHz than Category 6. 7 dB Minimum – Improvement in Near End Crosstalk vs. Category 6 NEXT. • 33 dB Minimum ACR @ 100 MHz and positive ACR • • • to 460 MHz. Application – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, IEEE 802.3af Power Over Ethernet for VoIP, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TPPMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps, 1.2, 2.4 and 4.8 Gbps. Enhanced Performance Parameters – All electrical characteristics proven to exceed TIA/EIA 568-B.2-1 and ISO/IEC 11801 Category 6 requirements: including NEXT and ELFEXT (Pair-to-Pair and Power Sum), Insertion Loss, Return Loss, and Delay Skew. This cable and/or its manufacture are covered by US Patent Nos. 6,596,944, 6,074,503 and 5,424,491. * Warranty available with MAC and SystemMATE® programs. Electrical Characteristics STANDARDS: EXCEEDS TIA/EIA 568-B.2-1 CAT 6 & ISO/IEC 11801:2002 CAT 6 HORIZONTAL CABLE CONDUCTOR DCR: 6.71 V/100m (22.0 V/Mft) MAX Near End Crosstalk (NEXT) Power Sum NEXT (PS NEXT) Worst Case ACR and Power Sum ACR Input Impedance DCR UNBALANCE: 3% MAX MUTUAL CAPACITANCE: 46 pF/m (14 pF/ft) NOM CAPACITANCE UNBALANCE PAIR/GROUND: 33 pF/100m (100 pF/Mft) MAX CHARACTERISTIC IMPEDANCE: 100 V 67% (10-550 MHz) INPUT IMPEDANCE: 100 V 612% (1-100 MHz) 100 V 615% (>100-350 MHz) 100 V 622% (>350 MHz) PROPAGATION DELAY: 506 + 36/√ƒ ns/100m MAX (1-500 MHz) DELTA DELAY (SKEW): 30 ns/100m MAX (10-500 MHz) NOMINAL VELOCITY OF PROPAGATION (NVP): PLENUM 72% NON-PLENUM 68% Safety listed to NEC (NFPA 70) 6 MOHAWK Verified by ETL to TIA/EIA-568-B.2-1 Jacket Colors for 4-Pair Non-Plenum Jacket Color Cable DIagram Mohawk # Jacket Insulation Jacket Color Mohawk # RED PINK VIOLET ORANGE BLACK M57621 M57867 M57870 M57868 M57869 M57418 M57419 M57420 M57421 M57422 WHITE BLUE YELLOW GREEN GRAY Conductor Jacket Colors for 4-Pair Plenum FlexWeb Jacket Color Ripcord Mohawk # Jacket Color Mohawk # RED PINK VIOLET ORANGE BLACK M57620 M57750 M57860 M57861 M57866 M57413 M57414 M57415 M57416 M57417 WHITE BLUE YELLOW GREEN GRAY Custom colors available; please consult the factory. FREQ (MHz) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 500.0 550.0 600.0 650.0 750.0 INSERTION LOSS (dB/100m) avg 1.6 1.8 3.3 4.7 5.2 6.7 7.4 8.3 9.3 13.4 17.1 21.7 24.9 28.1 31.1 33.8 36.5 41.4 43.7 46.0 48.1 52.3 NEXT (dB/100m) max 1.7 1.9 3.5 4.9 5.5 7.0 7.8 8.7 9.8 14.1 18.0 22.8 26.2 29.6 32.7 35.6 38.4 43.6 46.0 48.4 50.6 55.0 avg 93 91 82 78 76 73 72 70 69 64 61 58 57 55 54 53 52 51 50 50 49 48 ACR (dB/100m) min 83.0 81.3 72.3 67.8 66.3 63.2 61.8 60.3 58.9 54.4 51.3 48.4 46.8 45.3 44.1 43.1 42.3 40.8 40.2 39.6 39.1 38.2 min 81.3 79.4 68.8 62.9 60.8 56.2 54.0 51.6 49.1 40.3 33.3 25.6 20.6 15.7 11.4 7.5 3.9 - PS-NEXT (dB/100m) avg 86 84 75 71 69 66 65 63 62 57 54 51 50 48 47 46 45 44 43 43 42 41 PS-ACR (dB/100m) min 81.0 79.3 70.3 65.8 64.3 61.2 59.8 58.3 56.9 52.4 49.3 46.4 44.8 43.3 42.1 41.1 40.3 38.8 38.2 37.6 37.1 36.2 min 79.3 77.4 66.8 60.9 58.8 54.2 52.0 49.6 47.1 38.3 31.3 23.6 18.6 13.7 9.4 5.5 1.9 - ELFEXT PS-ELFEXT (dB/100m) (dB/100m) min 74.8 62.8 56.7 54.8 50.7 48.8 46.8 44.9 38.9 34.8 31.0 28.8 26.8 25.3 23.9 22.8 20.8 - min 72.8 60.8 54.7 52.8 48.7 46.8 44.8 42.9 36.9 32.8 29.0 26.8 24.8 23.3 21.9 20.8 18.8 - RL (dB) DELAY (ns/100m) min 20.0 24.2 26.3 27.0 27.0 27.0 26.5 25.9 24.2 23.1 22.0 21.4 20.9 20.4 20.1 19.7 19.2 19.0 18.8 18.6 18.2 max 542.0 524.0 518.7 517.4 515.0 514.0 513.2 512.4 510.6 509.6 508.9 508.5 508.3 508.1 507.9 507.8 507.6 - Values above 500 MHz are for engineering information only. Jacket Type Diameter inch mm Mohawk Part No. Cable Type Dielectric Type Weight lbs/M' kg/km Listings M57418 Non-Plenum 4 PAIR 23 AWG UTP Thermoplastic White PVC .247 6.27 34 51 C(UL)US CMR M57413 Plenum 4 PAIR 23 AWG UTP Dual Insulation** FEP on all 4 pairs . White ThermoPlen®* .244 6.20 37 55 C(UL)US CMP M58405 PlenumPlus™ 4 Pair 23 AWG UTP FEP White Smokeguard®† FP Rated for 125° C .220 5.59 36 54 UL CMP Limited Combustible c(UL) CMP *Plenum rated Thermoplastic. **US Patent No. 5,563,377. †Smokeguard is a registered trademark of AlphaGary. For pair colors see chart A on page 59. Packaging Options Put-Up Package Number Per Pallet Pallet Size 1000 Ft. 14” Reels 36 42” x 42” 1000 Ft. Boxes (15! s ”W x 11! f ”D x 14! f ”H) 33 45” x 48” 1000 Ft. Reel in a Box (12# f ”W x 12# f ”D x 12& k ”H) 27 42” x 42” Above part numbers are for reels only. Add “B” to end of Mohawk # for boxes, or “RB” for Reel-in-a-box packaging. Bulk put-ups available upon request; please consult the factory. MOHAWK 7 Category 6e UTP AdvanceNet ® AdvanceNet is unshielded twisted pair cable tested to 650 MHz and ETL verified to TIA/EIA 568-B.2-1 Category 6. With the new Mini FlexWeb core separator, the AdvanceNet cable isolates the pairs throughout the length of the cable, while providing a smaller installer-friendly cable. ® • • 25 Year Warranty* 28 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, IEEE 802.3af Power Over Ethernet for VoIP, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps, 1.2 and 2.4 Gbps. Tested to 650 MHz • 13 dB Minimum – Improvement in Near End Crosstalk • • • vs. Category 5e NEXT. .25 ns/meter Maximum Skew – Tightly controlled propagation delay. Enhanced Performance Parameters – All electrical characteristics proven to exceed TIA/EIA 568-B.2-1 and ISO/IEC 11801 Category 6 requirements: NEXT and ELFEXT (Pair-to-Pair and Power Sum), Insertion Loss, Return Loss, and Delay Skew. This cable and/or its manufacture are covered by US Patent Nos. 6,596,944, 6,074,503 and 5,424,491. * Warranty available with MAC and SystemMATE® programs. Electrical Characteristics STANDARDS: EXCEEDS TIA/EIA 568-B.2-1 CAT 6, ISO/IEC 11801:2002 CAT 6, & IEC 61156-5 CAT 6 HORIZONTAL CABLE CONDUCTOR DCR: 8.9 V/100m (27.1 V/Mft) MAX DCR UNBALANCE: 3% MAX Near End Crosstalk (NEXT) Power Sum NEXT (PS NEXT) Worst Case ACR and Power Sum ACR Input Impedance MUTUAL CAPACITANCE: 46 pF/m (14 pF/ft) NOM CAPACITANCE UNBALANCE PAIR/GROUND: 66 pF/100m (200 pF/Mft) MAX CHARACTERISTIC IMPEDANCE: 100 V 6 15% (1-350 MHz) INPUT IMPEDANCE: 100 V 6 15% (1-100 MHz) 100 V 6 18% (>100-200 MHz) 100 V 6 22% (>200-350 MHz) PROPAGATION DELAY: 534 + 36/√ƒ ns/100m MAX DELTA DELAY (SKEW): 25 ns/100m MAX NOMINAL VELOCITY OF PROPAGATION (NVP): PLENUM 72% NON-PLENUM 68% Safety listed to NEC (NFPA 70) 8 MOHAWK Verified by ETL to TIA/EIA-568-B.2-1 Jacket Colors for 4-Pair Non-Plenum Jacket Color Cable DIagram Mohawk # Jacket Insulation Jacket Color Mohawk # GREEN RED ORANGE BLACK VIOLET M57206 M57207 M57208 M57209 M57210 M56889 M57202 M57203 M57204 M57205 WHITE BLUE PINK YELLOW GRAY Conductor Jacket Colors for 4-Pair Plenum FlexWeb Jacket Color Ripcord Mohawk # Jacket Color Mohawk # GREEN RED ORANGE BLACK VIOLET M57197 M57198 M57199 M57200 M57201 M56905 M57193 M57194 M57195 M57196 WHITE BLUE PINK YELLOW GRAY Custom colors available; please consult the factory. FREQ (MHz) INSERTION LOSS (dB/100m) avg 1.6 1.8 3.5 4.9 5.6 7.1 7.9 8.8 10.0 14.3 18.4 23.4 27.0 30.5 33.9 37.0 40.0 45.5 48.2 50.7 53.2 .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 500.0 550.0 600.0 650.0 NEXT (dB/100m) max 1.8 2.0 3.8 5.3 5.9 7.5 8.4 9.4 10.6 15.3 19.7 25.0 28.8 32.6 36.2 39.5 42.7 48.6 51.5 54.2 56.8 avg 90 88 79 75 73 70 69 67 66 61 58 55 54 52 51 50 49 48 47 47 46 ACR (dB/100m) min 80.0 78.3 69.3 64.8 63.3 60.2 58.8 57.3 55.9 51.4 48.3 45.4 43.8 42.3 41.1 40.1 39.3 37.8 37.2 36.6 36.1 min 78.2 76.3 65.5 59.5 57.4 52.7 50.4 47.9 45.3 36.1 28.6 20.4 15.0 9.7 4.9 0.6 - PS-NEXT (dB/100m) avg 83 81 72 68 66 63 62 60 59 54 51 48 47 45 44 43 42 41 40 40 39 min 78.0 76.3 67.3 62.8 61.3 58.2 56.8 55.3 53.9 49.4 46.3 43.4 41.8 40.3 39.1 38.1 37.3 35.8 35.2 34.6 34.1 PS-ACR (dB/100m) min 76.2 74.3 63.5 57.5 55.4 50.7 48.4 45.9 43.3 34.1 26.6 18.4 13.0 7.7 2.9 - ELFEXT PS-ELFEXT (dB/100m) (dB/100m) min 70.0 58.0 51.9 50.0 45.9 44.0 42.0 40.1 34.1 30.0 26.2 24.0 22.0 20.5 19.1 18.0 16.0 - min 68.0 56.0 49.9 48.0 43.9 42.0 40.0 38.1 32.1 28.0 24.2 22.0 20.0 18.5 17.1 16.0 14.0 - RL (dB) min 20.0 24.2 26.3 27.0 27.0 27.0 26.5 25.9 24.2 23.1 22.0 21.4 20.9 20.4 20.1 19.7 19.2 19.0 18.8 18.6 Values above 350 MHz are for engineering information only. . Jacket Type Diameter inch mm Mohawk Part No. Cable Type Dielectric Type Weight lbs/M' kg/km Listings M56889 Non-Plenum 4 PAIR 23 AWG UTP Thermoplastic White PVC .225 5.72 30 45 C(UL)US CMR M56905 Plenum 4 PAIR 23 AWG UTP Dual Insulation** FEP on all 4 pairs White ThermoPlen®* .225 5.72 33 49 C(UL)US CMP M58414 PlenumPlus™ 4 PAIR 23 AWG UTP FEP White Smokeguard®† FP Rated for 125° C .200 5.08 31 46 UL CMP Limited Combustible c(UL) CMP *Plenum rated Thermoplastic. **US Patent No. 5,563,377. †Smokeguard is a registered trademark of AlphaGary. For pair colors see chart A on page 59. Packaging Options Put-Up Package Number Per Pallet Pallet Size 1000 Ft. 14” Reels 36 42” x 42” 1000 Ft. Boxes (15! s ”W x 11! f ”D x 14! f ”H) 33 45” x 48” 1000 Ft. Reel in a Box (12# f ”W x 12# f ”D x 12& k ”H) 27 42” x 42” Above part numbers are for reels only. Add “B” to end of Mohawk # for boxes, or “RB” for Reel-in-a-box packaging. Bulk put-ups available upon request; please consult the factory. MOHAWK 9 Category 6 UTP ™ 6 LAN Tested to 550 MHz ETL verified to TIA/EIA 568-B.2-1 Category 6. • • • 9 dB Minimum – Improvement in Near End Crosstalk vs. Category 5e NEXT. • Enhanced Performance Parameters – All electrical characteristics proven to meet TIA/EIA 568-B.2-1 and ISO/IEC 11801 Category 6 requirements: NEXT and ELFEXT (Pair-to-Pair and Power Sum), Insertion Loss, Return Loss, and Delay Skew. This cable and/or its manufacture is covered by US Patent Nos. 6,998,537, 6,570,095 and 5,424,491. • 20 Year Warranty* 24 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, IEEE 802.3af Power Over Ethernet for VoIP, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps, 1.2 and 2.4 Gbps. • * Warranty available with MAC and SystemMATE® programs. With flat tape core separator throughout the length of the cable. Electrical Characteristics STANDARDS: MEETS TIA/EIA 568-B.2-1 CAT 6 & ISO/IEC 11801:2002 CAT 6 HORIZONTAL CABLE CONDUCTOR DCR: 8.9 V/100m (27.1 V/Mft) MAX DCR UNBALANCE: 3% MAX Near End Crosstalk (NEXT) Power Sum NEXT (PS NEXT) Worst Case ACR and Power Sum ACR Input Impedance MUTUAL CAPACITANCE: 46 pF/m (14 pF/ft) NOM CAPACITANCE UNBALANCE PAIR/GROUND: 66 pF/100m (200 pF/Mft) MAX CHARACTERISTIC IMPEDANCE: 100 V 6 15% (1-250 MHz) INPUT IMPEDANCE: 100 V 6 15% (1-100 MHz) 100 V 6 20% (>100-200 MHz) 100 V 6 25% (>200 MHz) PROPAGATION DELAY: 534 + 36/√ƒ ns/100m MAX DELTA DELAY (SKEW): 25 ns/100m MAX NOMINAL VELOCITY OF PROPAGATION (NVP): PLENUM 72% NON-PLENUM 68% WHERE ƒ = FREQUENCY IN MHz from .772 to 250 MHz. Safety listed to NEC (NFPA 70) 10 MOHAWK Verified by ETL to TIA/EIA-568-B.2-1 Jacket Colors for 4-Pair Non-Plenum Jacket Color Cable DIagram Mohawk # Jacket Insulation Jacket Color Mohawk # GREEN RED ORANGE BLACK VIOLET M58296 M58297 M58298 M58299 M58300 M58291 M58292 M58293 M58294 M58295 WHITE BLUE PINK YELLOW GRAY Conductor Jacket Colors for 4-Pair Plenum Core Separator Jacket Color Jacket Color Mohawk # GREEN RED ORANGE BLACK VIOLET M58286 M58287 M58288 M58289 M58290 M58280 M58281 M58282 M58283 M58285 WHITE BLUE PINK YELLOW GRAY Ripcord Mohawk # Custom colors available; please consult the factory. FREQ (MHz) INSERTION LOSS (dB/100m) avg 1.7 1.9 3.6 5.1 5.7 7.3 8.1 9.1 10.2 14.8 19.0 24.2 27.8 31.5 35.0 38.2 41.3 47.0 49.7 .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 500.0 550.0 NEXT (dB/100m) max 1.8 2.0 3.8 5.3 6.0 7.6 8.5 9.5 10.7 15.4 19.8 25.2 29.0 32.8 36.4 39.8 43.0 48.9 51.8 avg 82 80 71 67 65 62 61 59 58 53 50 47 46 44 43 42 41 40 39 ACR (dB/100m) min 76.0 74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 41.4 39.8 38.3 37.1 36.1 35.3 33.8 33.2 min 74.2 72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32.0 24.5 16.2 10.8 5.5 0.7 - PS-NEXT (dB/100m) avg 77 75 66 62 60 57 56 54 53 48 45 42 41 39 38 37 36 35 34 min 74.0 72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 39.4 37.8 36.3 35.1 34.1 33.3 31.8 31.2 PS-ACR (dB/100m) min 72.2 70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30.0 22.5 14.2 8.8 3.5 - ELFEXT PS-ELFEXT (dB/100m) (dB/100m) min 67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 24.0 21.8 19.8 18.3 16.9 - min 64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 21.0 18.8 16.8 15.3 13.9 - RL (dB) min 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 16.8 16.3 15.9 15.2 14.9 Values above 250 MHz are for engineering information only. Jacket Type Diameter inch mm Mohawk Part No. Cable Type Dielectric Type Weight lbs/M' kg/km Listings M58291 Non-Plenum 4 PAIR 24 AWG UTP Thermoplastic White PVC .216 5.49 26 37 C(UL)US CMR M58280 Plenum 4 PAIR 24 AWG UTP Dual Insulation** FEP on all 4 pairs White ThermoPlen®* Rated for 125° C .208 5.28 29 43 C(UL)US CMP *Plenum rated Thermoplastic. ** US Patent No. 5,563,377. For pair colors see chart A on page 59. Packaging Options Put-Up Package Number Per Pallet Pallet Size 1000 Ft. 14” Reels 36 42” x 42” 1000 Ft. Boxes (15! s ”W x 11! f ”D x 14! f ”H) 33 45” x 48” 1000 Ft. Reel in a Box (12# f ”W x 12# f ”D x 12& k ”H) 27 42” x 42” Above part numbers are for reels only. Add “B” to end of Mohawk # for boxes, or “RB” for Reel-in-a-box packaging. Bulk put-ups available upon request; please consult the factory. MOHAWK 11 Category 5E+ UTP MegaLAN ® Tested to 400 MHz • Enhanced Performance Parameters – All electrical MegaLAN is ETL verified to Category 5e. • 20 Year Warranty* characteristics proven to exceed TIA/EIA 568-B Category 5e requirements: Near End Crosstalk, Characteristic Impedance, Insertion Loss, and Delay Skew. Also exceeds TIA/EIA 568-B.2 Category 5e requirements: Power Sum NEXT, and Far End Crosstalk – ELFEXT and PS-ELFEXT. • 20 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps and 1.2 Gbps. • Engineered for Future Applications – More than 10 years of service and still going strong, MegaLAN has a proven track record of successful installations. • User Friendly – No special stripping tools. No waiting for deliveries. No compromises. Proven Performance all the way. • 5 dB Minimum – Improvement in Near End Crosstalk vs. standard Category 5e NEXT. • Meets Return Loss – Category 5e Standard. • .25 ns/meter Maximum Skew – Tightly controlled propagation delay. • This cable and/or its manufacture are covered by US Patent No. 5,424,491. * Warranty available with MAC and SystemMATE® programs. Electrical Characteristics STANDARDS: EXCEEDS TIA/EIA 568-B.2 CAT 5e & ISO/IEC 11801:2002 CAT 5 HORIZONTAL CABLE CONDUCTOR DCR: 8.9 V/100m (27.1 V/Mft) MAX DCR UNBALANCE: 3% MAX Near End Crosstalk (NEXT) Power Sum NEXT (PS NEXT) Worst Case ACR and Power Sum ACR Input Impedance MUTUAL CAPACITANCE: 46 pF/m (14 pF/ft) NOM CAPACITANCE UNBALANCE PAIR/GROUND: 66 pF/100m (200 pF/Mft) MAX CHARACTERISTIC IMPEDANCE: 100 V 6 15% (1-400 MHz) INPUT IMPEDANCE: 100 V 6 15% (1-100 MHz) 100 V 6 22% (>100-200 MHz) PROPAGATION DELAY: 506 + 36/√ƒ ns/100m MAX DELTA DELAY (SKEW): 25 ns/100m MAX NOMINAL VELOCITY OF PROPAGATION (NVP): 72% PLENUM 68% NON-PLENUM Safety listed to NEC (NFPA 70) 12 MOHAWK Verified by ETL to TIA/EIA-568-B.2 Jacket Colors for 4-Pair Non-Plenum Jacket Color Cable DIagram Mohawk # Jacket Insulation Jacket Color Mohawk # VIOLET ORANGE RED BLACK GRAY M57048 M56954 M56670 M57129 M56746 M55989 M56167 M56094 M56095 M56165 WHITE BLUE PINK YELLOW GREEN Conductor Jacket Colors for 4-Pair Plenum Ripcord Jacket Color Mohawk # Jacket Color Mohawk # RED ORANGE BLACK VIOLET GREEN M56072 M56876 M56877 M56878 M56166 M55988 M56168 M56092 M56093 M56882 WHITE BLUE PINK YELLOW GRAY Custom colors available; please consult the factory. INSERTION LOSS (dB/100m) (dB/mft) FREQ (MHz) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 avg 1.6 1.8 3.6 5.2 5.8 7.3 8.3 9.3 10.4 15.1 19.6 25.0 28.8 32.8 36.5 40.0 43.2 max 1.8 2.0 4.0 5.7 6.4 8.1 9.1 10.2 11.4 16.4 21.0 26.6 30.5 34.4 38.0 41.4 44.6 NEXT (dB/100m) max 5.5 6.2 12.2 17.4 19.4 24.7 27.7 31.0 34.8 50 64 81 93 105 116 126 136 avg 82 80 70 66 64 62 60 59 58 54 50 48 46 45 44 43 42 ACR (dB/100m) min 72.0 70.3 61.3 56.8 55.3 52.2 50.8 49.3 47.9 43.4 40.3 37.4 35.8 34.3 33.1 32.1 31.3 min 72.2 70.3 59.3 53.1 50.9 46.1 43.7 41.1 38.5 29.0 21.3 12.9 7.3 1.9 - PS-NEXT (dB/100m) avg 75 73 63 59 58 56 54 52 51 47 43 41 40 38 37 36 35 min 70.0 68.3 59.3 54.8 53.3 50.2 48.8 47.3 45.9 41.4 38.3 35.4 33.8 32.3 31.1 30.1 29.3 PS-ACR ELFEXT PS-ELFEXT (dB/100m) (dB/100m) (dB/100m) min 68.2 66.3 55.3 49.1 46.9 42.1 39.7 37.1 34.5 25.0 17.3 8.9 3.3 - min 67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 24.0 21.8 19.8 - min 64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 21.0 18.8 16.8 - RL (dB) min 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 16.8 16.3 15.9 Values above 250 MHz are for engineering information only. Mohawk Part No. Cable Type Dielectric Type M55989 Non-Plenum 4 PAIR 24 AWG UTP Thermoplastic M55988 Plenum 4 PAIR 24 AWG UTP M57113 PlenumPlus™ 4 PAIR 24 AWG UTP Dual Insulation** FEP on all 4 pairs FEP Jacket Type Diameter inch mm Weight lbs/M' kg/km Listings White PVC .190 4.83 20 30 C(UL)US CMR White ThermoPlen®* .190 4.83 24 36 C(UL)US CMP White Smokeguard®† FP Rated for 125° C .175 4.45 26 39 UL, CMP Limited Combustible c(UL) CMP *Plenum rated Thermoplastic. **US Patent No. 5,563,377. †Smokeguard is a registered trademark of AlphaGary. For pair colors see chart A on page 59. Packaging Options Put-Up Package Number Per Pallet Pallet Size 1000 Ft. 12” Reels 60 38” x 48” 1000 Ft. Boxes (13& k ”W x 10! f ”D x 12! s ”H) 36 44” x 44” 1000 Ft. Reel in a Box (11& k ”W x 11# k ”D x 11& k ”H) 36 38” x 48” Above part numbers are for reels only. Add “B” to end of Mohawk # for boxes, or “RB” for Reel-in-a-box packaging. Bulk put-ups available upon request; please consult the factory. MOHAWK 13 Category 5e UTP 5e LAN ® Tested to 200 MHz Cable DIagram Jacket • 15 Year Warranty* • 14 dB Minimum ACR @ 100 MHz – Proven support Insulation for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps. Conductor Ripcord • 4 dB Minimum – Improvement in Near End Crosstalk vs. parameters specified...for 4 pair UTP in TIA/EIA 568-B.2, including PS-NEXT, Return Loss, ELFEXT and PS-ELFEXT. TIA/EIA 568-B Category 5. • ETL Verified to Category 5e. • .45 ns/meter Maximum Skew – Tightly controlled • propagation delay. • This cable and/or its manufacture are covered by US Patent No. 5,424,491. * Warranty available with MAC and SystemMATE® programs. Engineered for Future Applications – Tested for all Mohawk Part No. Cable Type Dielectric Type M57554 Non-Plenum 4 PAIR 24 AWG UTP Thermoplastic M57547 Plenum 4 PAIR 24 AWG UTP M58104 PlenumPlus™ 4 PAIR 24 AWG UTP Jacket Type Diameter inch mm Listings White PVC .190 4.83 20 30 C(UL)US CMR White ThermoPlen®* .180 4.57 23 34 C(UL)US CMP White Smokeguard®† FP Rated for 125° C .170 4.32 24 36 UL, CMP Limited Combustible c(UL) CMP Dual Insulation** FEP on all 4 pairs FEP Weight lbs/M' kg/km *Plenum rated Thermoplastic. **US Patent No. 5,563,377. †Smokeguard is a registered trademark of AlphaGary. For pair colors see chart A on page 59. Jacket Colors for 4-Pair Non-Plenum Jacket Colors for 4-Pair Plenum Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color Mohawk # WHITE BLUE PINK YELLOW GRAY M57554 M57553 M57555 M57556 M57552 GREEN RED ORANGE BLACK VIOLET M57557 M58008 M58009 M58010 M58007 WHITE BLUE PINK YELLOW GRAY M57547 M57546 M57548 M57550 M57545 GREEN RED ORANGE BLACK VIOLET M57551 M57887 M57924 M57936 M57761 Custom colors available; please consult the factory. Above part numbers are for reels only. Add “B” to end of Mohawk # for boxes, or “RB” for Reel-in-a-box packaging. FREQ (MHz) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 INSERTION LOSS (dB/100m) (dB/mft) avg 1.6 1.8 3.8 5.4 6.0 7.6 8.6 9.7 10.9 15.8 20.5 26.2 30.2 max 1.8 2.0 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17.0 22.0 28.1 32.4 max 5.5 6.3 13 18 20 25 28 32 36 52 67 86 99 NEXT (dB/100m) avg 79 77 68 64 62 60 58 57 56 52 48 45 43 min 68.0 66.3 57.3 52.8 51.3 48.2 46.8 45.3 43.9 39.4 36.3 33.4 31.8 ACR (dB/100m) min 66.2 64.3 53.2 47.0 44.8 40.0 37.5 34.9 32.2 22.4 14.3 5.3 - PS-NEXT (dB/100m) avg 70 68 57 54 52 50 48 47 46 42 38 35 33 min 64.0 62.3 53.3 48.8 47.3 44.2 42.8 41.3 39.9 35.4 32.3 29.4 27.8 PS-ACR (dB/100m) min 62.2 60.3 49.2 43.0 40.8 36.0 33.5 30.9 28.2 18.4 10.3 1.3 - ELFEXT PS-ELFEXT (dB/100m) (dB/100m) min 63.8 51.8 45.7 43.8 39.7 37.8 35.8 33.9 27.9 23.8 20.0 17.8 Values above 100 MHz are for engineering information only. Safety listed to NEC (NFPA 70) 14 MOHAWK Verified by ETL to TIA/EIA-568-B.2 min 60.8 48.8 42.7 40.8 36.7 34.8 32.8 30.9 24.9 20.8 17.0 14.8 RL (dB) min 20.0 23.0 24.5 25.0 25.0 25.5 24.3 23.6 21.5 20.1 18.8 18.0 UTP Category 5 & 3 Category 5 UTP • 14 dB Minimum ACR @ 100 MHz – Proven support for 155 Mbps ATM, 100 Mbps Fast Ethernet, 100 Mbps TP-PMD, 100VG-AnyLAN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps. Cable DIagram Jacket • 4 dB Minimum – Improvement in Near End Crosstalk Insulation vs. TIA-EIA 568-B Category 5. Conductor • .25 ns/meter Maximum Skew – Tightly controlled propagation delay. Ripcord • Engineered for Future Applications – Tested for parameters not specified for Category 5: 4 pair UTP in TIA.EIA 568-B.2, such as PS-NEXT, ACR, RL, and ELFEXT. Mohawk Part No. Jacket Type Diameter inch mm Cable Type Dielectric Type Shield Type Weight lbs/M' kg/km Listings M54568 Non-Plenum 4 PAIR 24 AWG UTP Thermoplastic None Lt. Gray PVC .190 4.83 20 30 C(UL)US CMR M54785 Non-Plenum Dual 4 Pair UTP/UTP Thermoplastic None Lt. Gray PVC .190x.395 4.83x10.03 43 64 C(UL)US CMR M54998 Plenum 4 PAIR 24 AWG UTP Dual Insulation** FEP on all 4 pairs None Gray ThermoPlen®* .180 4.57 23 34 C(UL)US CMP M55477 Plenum Dual 4 Pair UTP/UTP Dual Insulation** FEP on all 4 pairs None Gray ThermoPlen®* .180x.375 4.57x9.53 45 67 C(UL)US CMP M52995 Non-Plenum 4 PAIR 24 AWG UTP Thermoplastic None Lt. Gray PVC .161 4.09 21 31 C(UL)US CMR M55760 Plenum 4 PAIR 24 AWG UTP ThermoPlen®* None Gray ThermoPlen®* .161 4.09 21 31 C(UL)US CMP Category 5 Category 3 *Plenum rated Thermoplastic. **US Patent No. 5,563,377. For pair colors see chart A on page 59. Note: Also available in LSOH cable versions. Jacket Colors for Category 5 4-Pair Non-Plenum Jacket Colors for Category 5 4-Pair Plenum Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color WHITE BLUE PINK YELLOW GRAY M55995 M55436 M55959 M55980 M54568 RED ORANGE BLACK VIOLET GREEN M56009 M55721 M56230 M56210 M55994 WHITE BLUE PINK YELLOW GRAY Mohawk # M55530 M55586 M55837 M55915 M54998 Jacket Color Mohawk # RED ORANGE BLACK VIOLET GREEN M56256 M55902 M55901 M55900 M55916 Custom colors available; please consult the factory. Above part numbers are for reels only. Add “B” to end of Mohawk # for boxes, or “RB” for Reel-in-a-box packaging. Safety listed to NEC (NFPA 70) Verified by ETL to TIA/EIA-568-B.2 MOHAWK 15 Category 6 ScTP AdvanceNet ® Tested to 650 MHz AdvanceNet is screened twisted pair (ScTP or FTP) cable tested to 650 MHz that is third-party verified to Category 6. • .30 ns/meter Maximum Skew – Tightly controlled Now with FlexWeb construction, the AdvanceNet cable isolates the pairs throughout the length of the cable, while providing a round installer-friendly cable. • 100% insulation (plenum). • Enhanced Performance Parameters – All electrical ® propagation delay. characteristics proven to exceed TIA/EIA 568-B.2-1 and ISO/IEC 11801 Category 6 requirements: NEXT and ELFEXT (Pair-to-Pair and Power Sum), Insertion Loss, Return Loss, and Delay Skew. • 25 Year Warranty* • 24 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps, 1.2 and 2.4 Gbps. • Use All Shielded Components for a Shielded or Screened System – Mohawk strongly recommends the use of shielded or screened connecting hardware, and all shielded or screened cords: patch, work area and equipment cords should be used throughout the structured cabling system. • This cable and/or its manufacture are covered by US Patent Nos. 6,596,944, 6,074,503 and 5,424,491. • 9 dB Minimum – Improvement in Near End Crosstalk vs. standard Category 5e NEXT. *Warranty available with MAC and SystemMATE® programs. Electrical Characteristics STANDARDS: EXCEEDS TIA/EIA 568-B.2-1 CAT 6 & ISO/IEC 11801:2002 CAT 6 HORIZONTAL CABLE CONDUCTOR DCR: 8.9 V/100m (27.1 V/Mft) MAX DCR UNBALANCE: 3% MAX Near End Crosstalk (NEXT) Power Sum NEXT (PS NEXT) Worst Case ACR and Power Sum ACR Input Impedance MUTUAL CAPACITANCE: 46 pF/m (14 pF/ft) NOM CAPACITANCE UNBALANCE PAIR/GROUND: 66 pF/100m (200 pF/Mft) MAX CHARACTERISTIC IMPEDANCE: 100 V 6 15% (1-300 MHz) INPUT IMPEDANCE: 100 V 6 15% (1-100 MHz) 100 V 6 22% (>100-200 MHz) 100 V 6 32% (>200-350 MHz) PROPAGATION DELAY: 534 + 36/√ƒ ns/100m MAX DELTA DELAY (SKEW): 30 ns/100m MAX NOMINAL VELOCITY OF PROPAGATION (NVP): PLENUM 72% 68% NON-PLENUM Safety listed to NEC (NFPA 70) 16 MOHAWK Verified by ETL to TIA/EIA-568-B.2-1 Jacket Colors for 4-Pair Non-Plenum Jacket Color Cable DIagram Mohawk # Jacket Insulation Jacket Color Mohawk # GREEN RED ORANGE BLACK VIOLET M58160 M58161 M58162 M58163 M58164 M58155 M58156 M58157 M58158 M58159 WHITE BLUE PINK YELLOW GRAY Conductor Jacket Colors for 4-Pair Plenum Ripcord Jacket Color Drain Jacket Color Mohawk # GREEN RED ORANGE BLACK VIOLET M58180 M58181 M58182 M58183 M58184 M58175 M58176 M58177 M58178 M58179 WHITE BLUE PINK YELLOW GRAY Barrier/Shield Mohawk # Custom colors available; please consult the factory. FREQ (MHz) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 500.0 550.0 600.0 650.0 INSERTION LOSS (dB/100m) avg 1.7 1.9 3.6 5.0 5.6 7.1 7.9 8.9 10.0 14.4 18.5 23.6 27.1 30.7 34.0 37.2 40.2 45.7 48.4 51.0 53.5 NEXT (dB/1000ft) max 1.8 2.0 3.8 5.3 6.0 7.6 8.5 9.5 10.7 15.4 19.8 25.2 29.0 32.8 36.4 39.8 43.0 48.9 51.8 54.5 57.2 avg 86 82 73 69 67 66 64 63 62 58 54 52 50 49 48 47 46 45 44 43 42 ACR (dB/100m) min 76.0 74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 41.4 39.8 38.3 37.1 36.1 35.3 33.8 33.2 32.6 32.1 min 74.2 72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32.0 24.5 16.2 10.8 5.5 0.7 – – – – – – PS-NEXT (dB/100m) avg 80 75 65 61 60 58 56 54 53 49 45 43 42 40 39 38 37 36 35 35 35 min 74.0 72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 39.4 37.8 36.3 35.1 34.1 33.3 31.8 31.2 30.6 30.1 PS-ACR (dB/100m) ELFEXT (dB/100m) min 72.2 70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30.0 22.5 14.2 8.8 3.5 – – – – – – – min – 70.0 58.0 51.9 50.0 45.9 44.0 42.0 40.1 34.1 30.0 26.2 24.0 22.0 20.5 19.1 – – – – – PS-ELFEXT RL (dB/100m) (dB/100m) min – 68.0 56.0 49.9 48.0 43.9 42.0 40.0 38.1 32.1 28.0 24.2 22.0 20.0 18.5 17.1 – – – – – min – 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 16.8 16.3 15.9 15.2 14.9 14.7 14.4 Values above 350 MHz are for engineering information only. Jacket Type Diameter inch mm Weight lbs/M' kg/km Listings Mohawk Part No. Cable Type Dielectric Type M58155 Non-Plenum 4 PAIR 23 AWG ScTP Thermoplastic White PVC .265 6.73 44 65 C(UL)US CMR M58175 Plenum 4 PAIR 23 AWG ScTP FEP White ThermoPlen®* 6.48 .255 49 73 C(UL)US CMP *Plenum rated Thermoplastic. For pair colors see chart A on page 59. MOHAWK 17 Category 5E+ ScTP MegaLAN ® Tested to 400 MHz Category 5E+ cable in a screened twisted pair (ScTP or FTP) design, consisting of an overall tape/drain shield. • Enhanced Performance Parameters – All electrical characteristics proven to exceed TIA/EIA 568-B Category 5e requirements: Near End Crosstalk, Characteristic Impedance, Insertion loss and Delay Skew. Also exceeds TIA/EIA 568-B.2 Category 5e requirements: Power Sum NEXT, Return Loss, and Far End Crosstalk – ELFEXT and PS-ELFEXT. MegaLAN ScTP is ETL verified to Category 5e. • 20 Year Warranty* • 20 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps and 1.2 Gbps. • Engineered for Future Applications – Where cabling is to be installed in a high external noise location. This could be in the path of radar or next to a telecomm or a broadcast transmission point. Or is security an issue? When quality cable is properly installed, grounded, and tested, shielded cable provides measurably lower RF emissions. • Use All Shielded Components for a Shielded or Screened System – Mohawk strongly recommends the use of shielded or screened connecting hardware, and all shielded or screened cords: patch, work area and equipment cords should be used throughout the structured cabling system. • 5 dB Minimum – Improvement in Near End Crosstalk vs. standard Category 5e NEXT. •.30 ns/meter Maximum Skew – Tightly controlled propagation delay. •This cable and/or its manufacture are covered by US • 100% insulation (plenum). Patent No. 5,424,491. * Warranty available with MAC and SystemMATE® programs. Electrical Characteristics STANDARDS: EXCEEDS TIA/EIA 568-B.2 CAT 5e & ISO/IEC 11801:2002 CAT 5 HORIZONTAL CABLE CONDUCTOR DCR: 8.9 V/100m (27.1 V/Mft) MAX DCR UNBALANCE: 3% MAX Near End Crosstalk (NEXT) Power Sum NEXT (PS NEXT) Worst Case ACR and Power Sum ACR Input Impedance MUTUAL CAPACITANCE: 46 pF/m (14 pF/ft) NOM CAPACITANCE UNBALANCE PAIR/GROUND: 66 pF/100m (200 pF/Mft) MAX CHARACTERISTIC IMPEDANCE: 100 V 6 15% (1-400 MHz) INPUT IMPEDANCE: 100 V 6 15% (1-100 MHz) 100 V 6 22% (>100-200 MHz) PROPAGATION DELAY: 506 + 36/√ƒ ns/100m MAX DELTA DELAY (SKEW): 30 ns/100m MAX NOMINAL VELOCITY OF PROPAGATION (NVP): PLENUM 72% 68% NON-PLENUM Safety listed to NEC (NFPA 70) 18 MOHAWK Verified by ETL to TIA/EIA-568-B.2 Jacket Colors for 4-Pair Non-Plenum Jacket Color Cable DIagram Mohawk # Jacket Shield Jacket Color Mohawk # GREEN RED ORANGE BLACK VIOLET M57374 M57375 M57376 M57377 M57378 M55987 M57370 M57371 M57372 M57373 WHITE BLUE PINK YELLOW GRAY Insulation Jacket Colors for 4-Pair Plenum Conductor Jacket Color Barrier Mohawk # Mohawk # RED ORANGE BLACK VIOLET GREEN M57364 M57365 M57366 M57367 M57363 M55986 M57360 M57322 M57361 M57362 WHITE BLUE PINK YELLOW GRAY Drain Jacket Color Custom colors available; please consult the factory. FREQ (MHz) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 INSERTION LOSS (dB/100m) (dB/1000ft) avg 1.6 1.8 3.6 5.2 5.8 7.3 8.3 9.3 10.4 15.1 19.6 25.0 28.8 32.8 36.5 40.0 43.2 max 1.8 2.0 4.0 5.7 6.4 8.1 9.1 10.2 11.4 16.4 21.0 26.6 30.5 34.4 38.0 41.4 44.6 max 5.5 6.2 12.2 17.4 19.4 24.7 27.7 31.0 34.8 50 64 81 93 105 116 126 136 NEXT (dB/100m) avg 82 80 70 66 64 62 60 59 58 54 50 48 46 45 44 43 42 min 72.0 70.3 61.3 56.8 55.3 52.2 50.8 49.3 47.9 43.4 40.3 37.4 35.8 34.3 33.1 32.1 31.3 ACR (dB/100m) min 72.2 70.3 59.3 53.1 50.9 46.1 43.7 41.1 38.5 29.0 21.3 12.9 7.3 1.9 — — — PS-NEXT (dB/100m) avg 75 73 63 59 58 56 54 52 51 47 43 41 40 38 37 36 35 min 70.0 68.3 59.3 54.8 53.3 50.2 48.8 47.3 45.9 41.4 38.3 35.4 33.8 32.3 31.1 30.1 29.3 PS-ACR ELFEXT PS-ELFEXT (dB/100m) (dB/100m) (dB/100m) min 68.2 66.3 55.3 49.1 46.9 42.1 39.7 37.1 34.5 25.0 17.3 8.9 3.3 — — — — min — 67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 24.0 21.8 19.8 — — — min — 64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 21.0 18.8 16.8 — — — RL (dB) min — 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 16.8 16.3 15.9 Values above 250 MHz are for engineering information only. Jacket Type Diameter inch mm Mohawk Part No. Cable Type Dielectric Type M55987 Non-Plenum 4 PAIR 24 AWG ScTP Thermoplastic White PVC .245 6.22 32 48 C(UL)US CMR M55986 Plenum 4 PAIR 24 AWG ScTP FEP White ThermoPlen®* .224 5.69 33 49 C(UL)US CMP *Plenum rated Thermoplastic. Weight lbs/M' kg/km Listings For pair colors see chart A on page 59. MOHAWK 19 Category 5e ScTP 5e LAN ® Tested to 200 MHz Jacket • • Shield 15 Year Warranty* Insulation 14 dB Minimum ACR @ 100 MHz – Proven support for Gigabit Ethernet / 1000BASE-T / IEEE 802.3ab, ATM up to 155 Mbps, 100 Mbps Fast Ethernet / 100BASE-T / IEEE 802.3, ANSI.X3.263 FDDI TP-PMD, Ethernet / 10BASE-T / IEEE 802.3, 4 & 16 Mbps Token Ring / IEEE 802.5, T1/E1, xDSL, ISDN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps. • 4 dB Minimum – Improvement in Near End Crosstalk vs. TIA/EIA 568-B Category 5. • • ETL verified to Category 5e. .30 ns/meter Maximum Skew – Tightly controlled propagation delay. Conductor Barrier Drain • 100% insulation (plenum). • Engineered for Future Applications – Tested for all parameters specified...for 4 pair ScTP in TIA/EIA 568-B.2, including PS-NEXT, Return Loss, ELFEXT and PS-ELFEXT. * Warranty available with MAC and SystemMATE® programs. Jacket Type Diameter inch mm Mohawk Part No. Cable Type Dielectric Type M58145 Non-Plenum 4 PAIR 24 AWG ScTP Thermoplastic Lt. Gray PVC .232 5.89 30 45 C(UL)US CMR M58144 Plenum 4 PAIR 24 AWG ScTP FEP Gray ThermoPlen®* .218 5.54 32 48 C(UL)US CMP *Plenum rated Thermoplastic. Weight lbs/M' kg/km For pair colors see chart A on page 59. Jacket Colors for 4-Pair Non-Plenum Jacket Colors for 4-Pair Plenum Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color Mohawk # Jacket Color WHITE BLUE PINK YELLOW GRAY M58195 M58196 M58197 M58198 M58145 GREEN RED ORANGE BLACK VIOLET M58199 M58200 M58201 M58202 M58203 WHITE BLUE PINK YELLOW GRAY M58185 M58186 M58187 M58188 M58144 RED ORANGE BLACK VIOLET GREEN Custom colors available; please consult the factory. Safety listed to NEC (NFPA 70) 20 MOHAWK Listings Verified by ETL to TIA/EIA-568-B.2 Mohawk # M58190 M58191 M58192 M58193 M58189 ScTP Category 5 & 3 Category 5 ScTP • Category 5 cable in a screened twisted pair (ScTP) Jacket design, or overall shielded. Shield • 10 dB Minimum ACR @ 100 MHz – Proven support Insulation for 155 Mbps ATM, 100 Mbps Fast Ethernet, 100 Mbps TP-PMD, 100VG-AnyLAN, 550 MHz Broadband Video and standards under development such as ATM at 622 Mbps. Conductor Barrier Drain • .30 ns/meter Maximum Skew – Tightly controlled propagation delay. Jacket Type Diameter inch mm Weight lbs/M' kg/km Listings Cable Type Dielectric Type M54783 Non-Plenum 4 PAIR 24 AWG ScTP Thermoplastic Lt. Gray PVC .240 6.1 32 48 C(UL)US) CMR M55082 Plenum 4 PAIR 24 AWG ScTP FEP Gray ThermoPlen®* .230 5.84 34 51 C(UL)US CMP M53639 Non-Plenum 4 PAIR 24 AWG ScTP Thermoplastic Lt. Gray PVC .210 5.33 29 43 C(UL)US CMR M54708 Plenum 4 PAIR 24 AWG ScTP ThermoPlen®** Gray ThermoPlen®* .189 4.80 29 43 C(UL)US CMP Mohawk Part No. Category 5 Category 3 *Plenum rated Thermoplastic. For pair colors see chart A on page 59. Jacket Colors for Category 5 4-Pair Non-Plenum Jacket Color GRAY BLUE GREEN RED Mohawk # M54783 M56912 M57116 M56669 Jacket Color BLACK ORANGE WHITE VIOLET Mohawk # M57277 M57564 M57662 M57850 Jacket Colors for Category 5 4-Pair Plenum Jacket Color GRAY WHITE BLUE PINK Mohawk # M55082 M56760 M57009 M58143 Jacket Color GREEN RED BLACK Mohawk # M56823 M56809 M57269 Custom colors available; please consult the factory. Safety listed to NEC (NFPA 70) Verified by ETL to TIA/EIA-568-B.2 MOHAWK 21 High Pair Count Power Sum Backbone Cables** Cable Type -20ºC to +60ºC (-4ºF to +140ºF) STORAGE TEMP.: -20ºC to +75ºC (-4ºF to +167ºF) INSTALLATION TEMP.:* 25 and 50 pair Category 5 and 5e cables and/or their manufacture are covered by US Patent Nos. 5,821,466 and 5,424,491. Mohawk Part No. OPERATING TEMP.: 0ºC to +60ºC (+32ºF to +140ºF) * THE INSTALLATION TEMPERATURE REFERS TO THE TEMPERATURE OF THE CABLE WHILE BEING INSTALLED OR PULLED. DO NOT INSTALL BELOW 0ºC (+32ºF). Jacket Type Diameter inch mm Shield Type Weight lbs/M' kg/km Min Bend Radius inch mm Listings Category 5e: Non-Plenum M58141† 25 PAIR 24 AWG UTP None Lt. Gray PVC .470 11.94 119 177 4.7 119 C(UL)US CMR M58522 50 PAIR 24 AWG UTP None Lt. Gray PVC .750 19.05 252 375 7.5 191 C(UL)US CMR M58520 25 PAIR 24 AWG ScTP O/A ALUM/PLY W/DW Lt. Gray PVC .522 13.26 149 222 5.25 133 C(UL)US CMR Category 5e: Plenum M58142† 25 PAIR 24 AWG UTP None Gray FEP .430 10.92 137 204 4.3 109 C(UL)US CMP M58521 25 PAIR 24 AWG ScTP O/A ALUM/PLY W/DW Gray ThermoPlen®* .472 11.99 157 234 4.75 120 C(UL)US CMP Category 5: Non-Plenum M56753† 25 PAIR 24 AWG UTP None Lt. Gray PVC .470 11.94 119 177 4.7 119 C(UL)US CMR M57040† 50 PAIR 24 AWG UTP None Lt. Gray PVC .750 19.05 252 375 7.5 191 C(UL)US CMR M56832† 25 PAIR 24 AWG ScTP O/A ALUM/PLY W/DW Lt. Gray PVC .522 13.26 149 222 5.25 133 C(UL)US CMR Category 5: Plenum M56773† 25 PAIR 24 AWG UTP None Gray FEP .430 10.92 137 204 4.3 109 C(UL)US CMP M56700 25 PAIR 24 AWG ScTP O/A ALUM/PLY W/DW Gray ThermoPlen®* .472 11.99 157 234 4.75 120 C(UL)US CMP *Plenum rated Thermoplastic. †Verified by Independent Test Laboratories. For pair and binder colors see chart B on page 59. Category 5/5e Power Sum 25 Pair Packaging Options 22 MOHAWK Type Reel/Put-up Gross Weight (lbs.) Type Reel/Put-up Gross Weight (lbs.) Type Reel/Put-up Gross Weight (lbs.) Plenum 22” Reel 1000 Ft. 131 Plenum 36” Reel 5000 Ft. 655 Non-Plenum 36” Reel 2000 Ft. 245 Plenum 30” Reel 2000 Ft. 262 Non-Plenum 24” Reel 1000 Ft. 119 Non-Plenum 48” Reel 5000 Ft. 640 Mohawk Part No. Cable Type Jacket Type Diameter inch mm Shield Type Weight lbs/M' kg/km Min Bend Radius inch mm Listings Category 3: Non-Plenum M55700 25 PAIR 24 AWG UTP None Lt. Gray PVC .364 9.25 100 149 3.6 91 C(UL)US CMR M55216 50 PAIR 24 AWG UTP None Lt. Gray PVC .591 15.01 197 293 5.9 150 C(UL)US CMR M55211 100 PAIR 24 AWG UTP None Lt. Gray PVC .707 17.96 381 567 7.1 180 C(UL)US CMR M55212 200 PAIR 24 AWG UTP None Lt. Gray PVC 1.054 26.77 814 1211 10.5 267 C(UL)US CMR M57098 300 PAIR 24 AWG UTP None Lt. Gray PVC 1.222 31.04 1186 1765 12.25 311 C(UL)US CMR M57996 400 PAIR 24 AWG UTP None Lt. Gray PVC 1.590 40.38 1750 2604 16.0 406 C(UL)US CMR M55704 25 PAIR 24 AWG ScTP O/A ALUM/PLY W/DW Lt. Gray PVC .394 10.01 111 165 4.0 102 C(UL)US CMR Category 3: Plenum M56801 25 PAIR 24 AWG UTP None Gray ThermoPlen®* .389 9.88 123 183 3.9 99 C(UL)US CMP M56126 50 PAIR 24 AWG UTP None Gray ThermoPlen®* .550 13.97 224 333 5.5 140 C(UL)US CMP M56128 100 PAIR 24 AWG UTP None Gray ThermoPlen®* .786 19.96 467 695 7.9 201 C(UL)US CMP M56129 200 PAIR 24 AWG UTP None Gray ThermoPlen®* 1.088 27.64 942 1402 10.9 277 C(UL)US CMP M57211 300 PAIR 24 AWG UTP None Gray ThermoPlen®* 1.334 33.88 1397 2079 13.3 338 C(UL)US CMP M58349 400 PAIR 24 AWG UTP None Gray ThermoPlen®* 1.527 38.79 1760 2619 15.3 389 C(UL)US CMP M55073 25 PAIR 24 AWG ScTP O/A ALUM/PLY W/DW Gray ThermoPlen®* .346 8.79 115 171 3.5 88 C(UL)US CMP *Plenum rated Thermoplastic. For pair and binder colors see chart B on page 59. Category 3 High Pair Count Packaging Options Pair Count Reel/Put-up Gross Weight (lbs.) Pair Count Reel/Put-up Gross Weight (lbs.) Pair Count Reel/Put-up Gross Weight (lbs.) 25 20” Reel 1000 Ft. 123 100 30” Reel 1000 Ft. 467 200 72” Reel 5000 Ft. 4300 25 24” Reel 2000 Ft. 246 100 36” Reel 2000 Ft. 950 300 48” Reel 1000 Ft. 1897 25 36” Reel 5000 Ft. 620 100 42” Reel 2500 Ft. 1167 300 54” Reel 2000 Ft. 2800 25 36” Reel 6500 Ft. 805 100 48” Reel 4000 Ft. 1910 300 60” Reel 3000 Ft. 4200 50 22” Reel 1000 Ft. 224 100 54” Reel 5000 Ft. 2400 300 72” Reel 4000 Ft. 5600 50 30” Reel 2000 Ft. 455 200 42” Reel 1000 Ft. 814 400 54” Reel 1000 Ft. 1900 50 48” Reel 5000 Ft. 1160 200 54” Reel 2000 Ft. 1680 400 72” Reel 2000 Ft. 3900 MOHAWK 23 UTP & ScTP Patch Cables GigaLink™ Category 6e+ UTP Patch Cable — Tested to 750 MHz Mohawk Part No. M57634 Cable Type 4 PAIR 24 AWG (7/32) TC UTP Dielectric Type Shield Type Thermoplastic None Jacket Type Diameter inch mm Weight lbs/M' kg/km White PVC .226 5.7 Listings 29 43 C(UL)US CMG 25 37 C(UL)US CMG For pair colors see chart A on page 59. Jacket Colors/Mohawk# BLUE -- M57635 RED -- M57641 GREEN -- M57638 YELLOW -- M57637 Additional colors & custom colors available - please consult the factory. AdvanceLink® Category 6e UTP Patch Cable — Tested to 650 MHz M57507 4 PAIR 24 AWG (7/32) TC UTP Thermoplastic None White PVC .216 5.49 For pair colors see chart A on page 59. Jacket Colors/Mohawk# BLUE -- M57508 RED -- M57519 GREEN -- M57512 YELLOW -- M57511 Additional colors & custom colors available - please consult the factory. MegaLink™ Category 5e+ UTP & ScTP Patch Cable Shield Type Jacket Type Diameter inch mm Weight lbs/M' kg/km Mohawk Part No. Cable Type Dielectric Type M56726 4 PAIR 24 AWG (7/32) TC UTP Thermoplastic None White PVC .200 5.10 25 37 C(UL)US CMG M57542 4 PAIR 26 AWG (7/34) TC ScTP Thermoplastic O/A ALUM/PLY W/DW White PVC .203 5.16 23 34 C(UL)US CMG Listings For pair colors see chart A on page 59. Jacket Colors/Mohawk# for 4-Pair UTP BLUE -- M57076 RED -- M57073 GREEN -- M57075 YELLOW -- M56985 Jacket Colors/Mohawk# for 4-Pair ScTP BLUE -- M57544 RED -- M57770 GREEN -- M58219 YELLOW -- M58218 Additional colors & custom colors available - please consult the factory. 5e LAN® Category 5e UTP & ScTP Patch Cable M58126 4 PAIR 24 AWG (7/32) TC UTP Thermoplastic None White PVC .200 5.10 25 37 C(UL)US CMG M58208 4 PAIR 26 AWG (7/34) TC ScTP Thermoplastic O/A ALUM/PLY W/DW White PVC .203 5.16 23 34 C(UL)US CMG For pair colors see chart A on page 59. Jacket Colors/Mohawk# for 4-Pair UTP BLUE -- M58127 RED -- M58133 GREEN -- M58130 YELLOW -- M58129 Jacket Colors/Mohawk# for 4-Pair ScTP BLUE -- M58209 RED -- M58214 GREEN -- M58213 YELLOW -- M58211 Additional colors & custom colors available - please consult the factory. 24 MOHAWK ARMM Riser Cable Multi-Pair 24 AWG Category 3 ARMM Riser Cable is a rugged multi-pair cable that exceeds Category 3 Cable for use in backbone cabling systems as described in TIA/EIA 568-B. The cable consists of #24 AWG solid bare copper insulated conductors, assembled into twisted pairs, core wrap, corrugated aluminum shield bonded to an overall PVC jacket. The cable is riser (non-plenum) rated for use as a vertical run in a shaft and for general purpose communications use in accordance with Article 800 of the National Electrical Code (NEC). The cable is UL (USA) & c(UL) (CANADA) listed for this application by passing UL 1666 Riser Cable Flammability test. Mohawk Part No. Cable Type Shield Type Jacket Diameter inch mm Weight lbs/M’ kg/km Min Bend Radius inch mm Listings Multi-Pair 24 AWG Category 3 M58452 25 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC .470 11.9 115 171 4.7 119 UL, c(UL) CMR M58460 50 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC .660 16.8 230 342 6.9 188 UL, c(UL) CMR M58461 75 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC .760 19.3 345 519 7.8 190 UL, c(UL) CMR M58453 100 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC .850 21.6 412 613 8.5 215 UL, c(UL) CMR M58462 150 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC .990 25.1 616 918 9.9 261 UL, c(UL) CMR M58454 200 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC 1.10 27.9 820 1222 11 280 UL, c(UL) CMR M58455 250 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC 1.22 30.9 950 1415 12.2 310 UL, c(UL) CMR M58456 300 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC 1.32 33.5 1100 1693 13.2 335 UL, c(UL) CMR M58457 400 PAIR 24 AWG ARMM O/A .008 CORRUGATED ALUMINUM Gray PVC 1.50 38.1 1400 2086 15 380 UL, c(UL) CMR For pair and binder colors see chart D on page 59. MOHAWK 25 Special Applications TM LAN-Trak OSP Outside Plant Cable LAN-Trak OSP delivers TIA/EIA 568-B Category 5, 5e+, or 6 electrical performance in an outside plant cable, because even small amounts of moisture or water in the cable will degrade the electrical performance of a Category cable. These cables are designed for exposure to the elements. Jacketed with black UV resistant polyethylene, they employ a craft-friendly semidry flooding material that cleans easily from the cable core. These cables allow you to extend your current network to outdoor satellite structures such as temporary classrooms or trailers in a campus environment. They are also well suited for runs under concrete slabs and in other wet locations. These cables are offered in both unshielded (UTP) and the more robust shielded (ScTP) cables. Also, the NEC may require a Category 5, 5e, or 6 rated protection Traditional petroleum based gels such as “icky-pick” result in hard to clean and time consuming cable prep time. This thixotropic gel has a dry, soft texture that is dermally safe and cleans easily with citrus based cleaners. The result is faster cable prep time, quicker clean-ups and happier technicians. Mohawk Part No. Cable Type device. As with all horizontal cables, run length is limited to 90 meters (295 feet) per TIA/EIA 568-B for Category 5, 5e, or 6 operation. Jacket Diameter Inch mm Weight lbs/M’ kg/km Min. Bend Radius Inch mm AdvanceNet® LAN-Trak OSP Category 6 Cable M57622*** 4 PAIR 24 AWG Duct/Aerial Lashed .271 6.88 36 54 2.75 70 M57623*** 4 PAIR 24 AWG Direct Burial (Shielded) .460 11.68 99 147 6.90 175 MegaLAN® LAN-Trak OSP Category 5E+ Cable M57561* 4 PAIR 24 AWG Duct/Aerial Lashed .251 6.38 31 46 2.50 61 M57562* 4 PAIR 24 AWG Direct Burial (Shielded) .380 9.65 88 131 5.70 145 .730 18.54 300 446 11.00 280 LAN-Trak OSP Category 5e Cable M58527** 25 PAIR 24 AWG Direct Burial (Shielded) LAN-Trak OSP Category 5 Cable M56871* 4 PAIR 24 AWG Outdoor Duct/Aerial Lashed .196 4.98 22 33 2.00 51 M57041* 4 PAIR 24 AWG Aerial Lashed .246 6.25 30 45 2.50 61 M57042* 4 PAIR 24 AWG Direct Burial (Shielded) .380 9.65 87 129 5.70 145 M57656** 25 PAIR 24 AWG Direct Burial (Shielded) .730 18.54 300 446 11.00 280 *US Patent No. 5,424,491. **US Patent Nos. 5,424,491; 5,821,466. ***US Patent Nos. 5,424,491; 6,074,503; 6,496,944. For 4 pair colors see chart A; for 25 pair colors see chart D on page 59. 26 MOHAWK Special Applications VersaLAN CM TM Indoor/Outdoor Category 5e & 6 Cable Jacket Flooded Core The cable is suitable for use in buildings in wet locations and suitable for use outdoors in duct and for aerial lashing. It is fully water blocked and has a black sunlight resistant jacket. It is not suitable for direct burial. This product and/or its manufacture is covered by US patent No. 5,424,491. Category 5e Cable Detail Conductor Insulation Jacket The cable is NEC rated for general purpose communications use in accordance with Article 800 of the National Electrical Code (NEC). The cable is UL (USA) & c(UL) (CANADA) listed for this application by passing UL 1581 vertical tray flame test. Mohawk Part No. Jacket Diameter inch mm Cable Type Insulation Conductor Category 6 Cable Detail FlexWeb Flooded Core Weight lbs/M’ kg/km Min. Bend Radius inch mm Listings M58762 Cat 5e 4 PAIR 24 AWG UTP .251 6.38 38 57 2.50 61 C(UL)US CM-LS M58772 Cat 6 4 PAIR 24 AWG UTP .271 6.88 43 64 2.75 70 C(UL)US CM-LS Electrical Characteristics - Category 5e FREQ (MHz) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 INSERTION LOSS (dB/100m) (dB/mft) avg 1.6 1.8 3.6 5.2 5.8 7.3 8.3 9.3 10.4 15.1 19.6 25.0 28.8 32.8 36.5 40.0 43.2 max 1.8 2.0 4.0 5.7 6.4 8.1 9.1 10.2 11.4 16.4 21.0 26.6 30.5 34.4 38.0 41.4 44.6 max 5.5 6.2 12.2 17.4 19.4 24.7 27.7 31.0 34.8 50 64 81 93 105 116 126 136 NEXT (dB/100m) avg 82 80 70 66 64 62 60 59 58 54 50 48 46 45 44 43 42 min 72.0 70.3 61.3 56.8 55.3 52.2 50.8 49.3 47.9 43.4 40.3 37.4 35.8 34.3 33.1 32.1 31.3 ACR (dB/100m) min 72.2 70.3 59.3 53.1 50.9 46.1 43.7 41.1 38.5 29.0 21.3 12.9 7.3 1.9 - PS-NEXT (dB/100m) avg 75 73 63 59 58 56 54 52 51 47 43 41 40 38 37 36 35 min 70.0 68.3 59.3 54.8 53.3 50.2 48.8 47.3 45.9 41.4 38.3 35.4 33.8 32.3 31.1 30.1 29.3 PS-ACR ELFEXT PS-ELFEXT (dB/100m) (dB/100m) (dB/100m) min 68.2 66.3 55.3 49.1 46.9 42.1 39.7 37.1 34.5 25.0 17.3 8.9 3.3 - min 67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 24.0 21.8 19.8 - min 64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 21.0 18.8 16.8 - RL (dB) min 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 16.8 16.3 15.9 Electrical Characteristics - Category 6 FREQ (MHz) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100.0 155.0 200.0 250.0 300.0 350.0 400.0 500.0 550.0 INSERTION LOSS (dB/100m) avg 1.6 1.8 3.5 5.0 5.6 7.1 7.9 8.9 10.0 14.4 18.5 23.5 27.2 30.7 34.0 37.2 40.2 45.8 48.4 max 1.8 2.0 3.8 5.3 5.9 7.5 8.4 9.4 10.6 15.3 19.7 25.0 28.8 32.6 36.2 39.5 42.7 48.6 51.5 NEXT (dB/100m) avg 86 82 73 69 67 66 64 63 62 58 54 52 50 49 48 47 46 45 44 min 77.0 75.3 66.3 61.8 60.3 57.2 55.8 54.3 52.9 48.4 45.3 42.4 40.8 39.3 38.1 37.1 36.3 34.8 34.2 ACR (dB/100m) min 75.2 73.3 62.5 56.5 54.4 49.7 47.4 44.9 42.3 33.1 25.6 17.4 12.0 6.7 2.0 - PS-NEXT (dB/100m) avg 80 75 65 61 60 58 56 54 53 49 45 43 42 40 39 38 37 36 35 min 75.0 73.3 64.3 59.8 58.3 55.2 53.8 52.3 50.9 46.4 43.3 40.4 38.8 37.3 36.1 35.1 34.3 32.8 32.2 PS-ACR ELFEXT PS-ELFEXT (dB/100m) (dB/100m) (dB/100m) min 73.2 71.3 60.5 54.5 52.4 47.7 45.4 42.9 40.3 31.1 23.6 15.4 10.0 4.7 0.0 - min 70.0 58.0 51.9 50.0 45.9 44.0 42.0 40.1 34.1 30.0 26.2 24.0 22.0 20.5 19.1 - min 68.0 56.0 49.9 48.0 43.9 42.0 40.0 38.1 32.1 28.0 24.2 22.0 20.0 18.5 17.1 - RL (dB) min 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 16.8 16.3 15.9 15.2 14.9 MOHAWK 27 Special Applications Cellular Tower Cables Category 6 Cable Detail FlexWeb Mohawk’s Cellular Tower Cable is an overall foil/braid shielded twisted pair cable intended for outdoor use. The compact rugged design is more flexible versus traditional armored cable typically used for this application. The foil/braid shield is an excellent choice where interference from external radio frequency or electromagnetic sources is a concern. Conductor Insulation Inner Jacket Braid Shield Outer Jacket These cables can be used not only to connect cellular phone sites, but other services including pagers, mobile radio, wireless data, personal communications service (PCS), and even newer services such as high speed broadband wireless internet access and weather collection equipment. Category 5E+/5 Cable Detail Conductor Insulation • EMI & RFI Protection – 60% Coverage Braid and 100% Coverage Metallic Foil Tape offer excellent EMI and RFI immunity in a tower environment, where there may be interference from other services located on the same tower now or in the future. • Easy Termination – Grounding is made simple because the braid can be crimped to a ground wire or clamped to the enclosure. • Gel filled and fully water-blocked – Prevents migration of water through the cable into sensitive electronics enclosures. Gel filling prevents corrosion of the conductors in the presence of water. • UV stabilized polyethylene outer jacket. • Meets applicable TIA/EIA Category grades. Inner Jacket Braid Shield Outer Jacket • Category 5, 5e, and 6 conductors should be terminated with 110 style Category rated jacks and the link completed with a short Category rated patch cable. • Standard RJ-45 plugs may not fit the Category 5e & 6 insulated conductors. Please consult the factory for the proper plug to fit these cables. Category 6 Cable Mohawk Part No. Cable Type M58577 4 PAIR 24 AWG Jacket Diameter inch mm .305 7.75 Weight lbs/M’ kg/km 49 73 Min. Bend Radius inch mm 3.0 76 Category 5E+ Cable Mohawk Part No. Cable Type M58463 4 PAIR 24 AWG Jacket Diameter inch mm .276 7.01 Weight lbs/M’ kg/km 43 64 Min. Bend Radius inch mm 2.8 71 Category 5 Cable 28 MOHAWK Mohawk Part No. Cable Type M58116 4 PAIR 24 AWG Jacket Diameter inch mm .250 6.35 Weight lbs/M’ kg/km 38 57 Min. Bend Radius inch mm 2.5 64 Special Applications ® OmniGUARD Industrial Grade Cables Rugged Cable Solutions for Extreme Environments Category 6e Cable Detail Today’s high-performance networking applications are moving from clean office environments out to greasy factory floors. Mohawk has responded with a line of Industrial Ethernet cable solutions. Tape Separator Conductor Insulation ® Inner Jacket Mohawk’s OmniGUARD Industrial Grade AdvanceNet and LAN copper cable families include both unshielded and shielded twisted pair constructions with Category 5, Category 5e or Category 6. These cables are designed to meet or exceed the performance standards of TIA/EIA-568-B and ISO/IEC11801 requirements, while providing added jacket compounds for durability. • Riser – For use as vertical runs in a shaft and for general-purpose communications. • Oil and UV-resistant – Black TPE jacket for excellent abrasion/ cut-through resistance. • -20°C to +60°C operating temperature. Outer Jacket Category 5e Stranded Cable Detail Category 5E+/5e/5 Cable Detail Conductor Conductor Insulation Insulation Inner Jacket Inner Jacket Outer Jacket Outer Jacket AdvanceNet® Category 6e UTP Cable Mohawk Part No. Cable Type Dielectric Type M58622 4 PAIR 24 AWG UTP Polyolefin Jacket Diameter inch mm .266 6.76 Weight lbs/M’ kg/km 39 58 MegaLAN® Category 5E+ UTP Cable Mohawk Part No. Cable Type Dielectric Type M58629 4 PAIR 24 AWG UTP Polyolefin Jacket Diameter inch mm .230 5.84 Weight lbs/M’ kg/km 30 45 5e LAN® Category 5e UTP Cable Mohawk Part No. Cable Type Dielectric Type M58620 4 PAIR 24 AWG UTP Polyolefin Jacket Diameter inch mm .230 5.84 Weight lbs/M’ kg/km 30 45 Category 5e Stranded UTP Cable Mohawk Part No. Cable Type Dielectric Type M58509 4 PAIR 24 AWG UTP STRANDED Polyolefin Jacket Diameter inch mm .260 6.60 Weight lbs/M’ kg/km 37 55 Category 5 UTP Cable Mohawk Part No. Cable Type Dielectric Type M58630 4 PAIR 24 AWG UTP Polyolefin Jacket Diameter inch mm .230 5.84 Weight lbs/M’ kg/km 30 45 MOHAWK 29 Special Applications TM Media Pull Bundled Cables BINDER JACKET Tired of setting up multiple cable reels for a common cable pull? Mohawk has the answer, Media Pull Bundled Cables. INSULATION CONDUCTOR Ultimate Versatility RIPCORD Media Pull Cables are multiples of individually jacketed components, such as 4 pair copper cable elements. The components are bundled together in a neat, clean and easy to use package. UL Approved Guaranteed Performance Mohawk’s line of Media Pull cables are fully approved to UL safety requirements for CMR (Riser) or CMP (Plenum) copper applications and for OFNR (Riser) or OFNP (Plenum) fiber optic applications. Individual cable elements are tested prior to cabling and tested again once the cabling operation is complete. This additional testing ensures that Media Pull constructions deliver the performance you’ve come to expect from an industry leader like Mohawk. Media Pull Category 6 Copper Components Number of Components Component Cable Type M57626 Non-Plenum 3 4 PAIR 24 AWG Thermoplastic PVC .247 6.27 .478 12.14 104 155 C(UL)US CMR M57627 Non-Plenum 4 Thermoplastic PVC .247 6.27 .536 13.61 132 196 C(UL)US CMR M57628 Non-Plenum 6 4 PAIR 24 AWG UTP 4 PAIR 24 AWG Thermoplastic PVC .247 6.27 .670 17.02 229 341 C(UL)US CMR M57629 Plenum 3 ThermoPlen®* .244 6.20 .525 13.33 129 192 C(UL)US CMP M57630 Plenum 4 ThermoPlen®* .244 6.20 .586 14.88 162 241 C(UL)US CMP M57631 Plenum 6 Dual Insulation** FEP on all 4 pairs Dual Insulation** FEP on all 4 pairs Dual Insulation** FEP on all 4 pairs ThermoPlen®* .244 6.20 .738 18.75 253 376 C(UL)US CMP Mohawk Part No. 4 PAIR 24 AWG UTP 4 PAIR 24 AWG UTP 4 PAIR 24 AWG UTP Dielectric Type Component Jacket Type Diameter inch mm Cable Diameter inch mm Weight lbs/M' kg/km Listings Media Pull MegaLAN® Category 5E+ Copper Components Number of Components Component Cable Type M57404 Non-Plenum 3 M57407 Non-Plenum 4 M57408 Non-Plenum 6 M57409 Plenum 3 M57410 Plenum 4 M57411 Plenum 6 4 PAIR 24 AWG UTP 4 PAIR 24 AWG UTP 4 PAIR 24 AWG UTP 4 PAIR 24 AWG UTP 4 PAIR 24 AWG UTP 4 PAIR 24 AWG UTP Mohawk Part No. Dielectric Type Cable Diameter inch mm Weight lbs/M' kg/km Listings Thermoplastic PVC .201 5.11 .389 9.88 70 104 C(UL)US CMR Thermoplastic PVC .201 5.11 .436 11.07 90 134 C(UL)US CMR Thermoplastic PVC .201 5.11 .543 13.79 136 202 C(UL)US CMR Dual Insulation** FEP on all 4 pairs Dual Insulation** FEP on all 4 pairs Dual Insulation** FEP on all 4 pairs ThermoPlen®* .186 4.72 .360 9.14 74 110 C(UL)US CMP ThermoPlen®* .186 4.72 .403 10.24 95 141 C(UL)US CMP ThermoPlen®* .186 4.72 .502 12.75 140 208 C(UL)US CMP *Plenum rated Thermoplastic. **U.S. Patent No. 5,563,377. For pair colors see chart A on page 59. For component jacket colors see page 33. 30 MOHAWK Component Jacket Type Diameter inch mm Special Applications Bundled Cables Both Fiber Optic & Copper Cables in One Media Pull™ Package BINDER BINDER JACKET JACKET BUFFERED FIBER BUFFERED FIBER STRENGTH MEMBERS STRENGTH MEMBERS INSULATION INSULATION CONDUCTOR CONDUCTOR RIPCORD RIPCORD Media Pull Bundled Cables are also available with Enhanced Copper Cables, AdvanceLite Fiber Cables and Coaxial Cables. Media Pull Category 5 UTP Copper & AdvanceLite® Fiber Optic Components Mohawk Part No. Number of Components Component Cable Type M96512 2 4 PAIR 24 AWG UTP Thermoplastic PVC .198 5.03 1 2 FIBER MM (62.5/125) DISTRIBUTION PVC PVC .184 4.67 M96633 3 4 PAIR 24 AWG UTP Thermoplastic PVC .198 5.03 1 Number of Components 4Component FIBER MM (62.5/125) Cable Type DISTRIBUTION PVC Mohawk Part No. PVC Jacket Component .200 Diameter 5.08 Type inch mm M96632 2 4 PAIR 24 AWG UTP FEP Thermoplen®* .180 4.57 1 2 FIBER MM (62.5/125) DISTRIBUTION ThermoPlen®* Thermoplen®* .184 4.67 3 4 PAIR 24 AWG UTP FEP Thermoplen®* .180 4.57 1 4 FIBER MM (62.5/125) DISTRIBUTION ThermoPlen®* Thermoplen®* .174 4.42 M95830 *Plenum rated Thermoplastic. Dielectric Type Dielectric Type Component Jacket Type Diameter inch mm Cable Diameter inch mm .374 9.50 Weight lbs/M' kg/km 64 95 Listings C(UL)US CMR UL, c(UL) OFNR OFN FT4 .431 10.95 Cable Diameter inch mm .351 8.92 85 126 Weight lbs/ kg/ M' km 60 89 C(UL)US CMR UL, c(UL) OFNR Listings OFN FT4 C(UL)US CMP UL, c(UL) OFNP OFN FT6 .387 9.83 83 124 C(UL)US CMP UL, c(UL) OFNP OFN FT6 For pair colors see chart A on page 59. Fiber Optic Component jacket colors: orange for multimode, yellow for single-mode. Component Jacket Colors Jacket Color Cable # Jacket Color Cable # Blue White Gray 1 2 3 Yellow Green Pink 4 5 6 MOHAWK 31 AdvanceLite ® Fiber Optic Cables Mohawk’s Range of Fiber Optic Cables for Gigabit Applications Mohawk has been manufacturing and testing fiber optic cable in accordance with many industry standards, including Telcordia, RUS and TIA/EIA, since 1990. Cables are listed by Underwriters Laboratories (UL) for compliance with the National Electrical Code and Canadian Electrical Code. Cables are available with fiber counts ranging from 1 to 216 in multimode, single-mode or hybrid versions. They are compatible with all major manufacturers’ connectivity hardware, including LID fusion splicers. Mohawk’s ISO 9001 registration assures our customers of consistent quality. Also, by working closely with customers, vendors, and industry organizations, Mohawk can help determine the best solution for a given application. AdvanceLite features fiber optimized for laser-based protocols, yet these cables are still compatible with LED systems. They provide guaranteed link lengths to handle multi-gigabit transmission while maintaining full compatibility with existing installed FDDI-grade cable. Multimode Fiber Grade Selector Short Wavelength or Long Wavelength, 50/125 micron or 62.5/125 micron, we have a solution for you. Mohawk has designed our Fiber Grade Selector to help you determine which multimode fiber type best suits your application. Legacy installations to emerging networking protocols are identified and the guaranteed performance of each fiber is given along with the appropriate optical specifications. Multimode — Grade 6 is a 50/125 fiber that exceeds TIA/EIA-568-B.3-1 (ISO 11801 OM3) for 500-meter lengths at 10 Gigabit data rates. Grade 5 is a 50/125 fiber that complies with TIA/EIA-568-B.3-1 (ISO 11801 OM3) for 300-meter lengths at 10 Gigabit data rates. (Formerly AdvanceLite 2000) Grade 4 is a 50/125 fiber that complies with TIA/EIA-568-B.3 (ISO 11801 OM2) and provides 600-meter link lengths for Gigabit Ethernet. (Formerly AdvanceLite 600) Grade 3 is a 62.5/125 fiber that complies with TIA/EIA-568-B.3 (ISO 11801 OM1) and provides up to 1000-meter link lengths for Gigabit Ethernet. (Formerly AdvanceLite 1000) Grade 2 is a 62.5/125 fiber that complies with TIA/EIA-568-B.3 (ISO 11801 OM1) and provides up to 550-meter link lengths for Gigabit Ethernet. (Formerly AdvanceLite 300) Grade 1 is FDDI grade 62.5/125 fiber and is the majority of the currently installed base of cable. Not recommended for future installations except as patch cordage. Single-Mode — Grade SM2 is a single-mode fiber that complies with ITU G.652.c/d. This is a low water peak fiber with advantages for CWDM applications. Grade SM1 is a single-mode fiber that complies with ITU G.652.a/b. Optical Fibers Supplied By: Fiber Optic Inventory When you need fiber optic cabling fast, Mohawk is ready and waiting for you. We stock over 100 of our most popular fiber optic cables, which can be shipped from our warehouse with no minimum order quantity necessary. Specific part numbers are listed on page 58, where you may determine if the cable you require is an inventory item.* 32 MOHAWK *Mohawk reserves the right to modify managed inventory items at any time with or without notice. Jacket Colors For outside plant cables, the standard jacket color is black. This includes loose tube, RiserLite® and VersaLite™ cables. For tight buffered cables, excluding simplex and duplex, the following is the standard jacket color code: Grades 2, 3, 4 — Orange Grades 5, 6 — Aqua Grades SM2 — Yellow Non-standard jacket colors are available. Optical Characteristics Meets or exceeds ISO/IEC 11801 OM1 2 Grade Glass Type OM1 62.5/125 MM AdvanceLite OM2 OM3 OM3 3 4 5 6 SM2 62.5/125 MM AdvanceLite 50/125 MM AdvanceLite 50/125 MM AdvanceLite 50/125 MM AdvanceLite Single-Mode Enhanced 6 Part Number Code (X) B D A C E W Operating Wavelength (nm) 850/1300 850/1300 850/1300 850/1300 850/1300 1310/1550 Min. OFL1 Bandwidth (MHz-km) 200/500 200/500 500/500 1500/500 3000/500 — Min. Laser2 Bandwidth (MHz-km) 220/500 385/500 510/500 2000/500 4700/500 — Max. Attenuation Loose Tube (dB/km) 3.25/1.0 3.25/1.0 3.0/1.0 3.0/1.0 3.0/1.0 0.40/0.30 Max. Attenuation Tight Buffered3 (dB/km) 3.50/1.25 3.50/1.25 3.50/1.25 3.50/1.25 3.50/1.25 0.80/0.50 100 Mbit Fast Ethernet Min. Link Length (meters S/L/E4) 300/2000 300/2000 300/2000 300/2000 300/2000 5000/— 1 Gigabit Ethernet Min. Link Length (meters S/L/E4) 300/550 500/1000 600/600 10005/600 10005/600 5000/— 10 Gigabit Ethernet Min. Link Length (meters S/L/E4) 33/300 33/300 82/300 300/300 550/300 10,000/ 40,000 1 OFL – Overfilled Launch 2 Effective Modal Bandwidth, determined by RML or DMD performance specifications 3 Max. Attenuation for Tight Buffered, Ribbon, Micro-Loose Tube & VersaLite Cables 4 S/L/E – Short wavelength (850 nm) / Long wavelength (1310 nm) / Extra long wavelength (1550 nm) 5 >2000 meters for engineered links 6 Low water peak Single-Mode suitable for CWDM use complies with ITU G.652.c/d MOHAWK 33 Riser AdvanceLite® Distribution Riser UL/c(UL) Type OFNR / OFN FT4 FIBER BUNDLE DETAIL Recommended Applications • Riser cabling • Office cabling • Computer room cabling OVERALL POLYESTER TAPE BARRIER OUTER JACKET ARAMID STRENGTH ELEMENTS Product Features • 900 µm tight buffered fibers • Color coded for easy termination • Flame Retardant • UL listed for code compliance • MSHA approved cables are available SPECIFIED FIBER (COLOR CODED) COLOR CODED JACKET UPJACKETED CENTRAL STRENGTH ELEMENT BUNDLES OF UP TO 12 FIBERS EACH >12-144 Fibers 2-12 Fibers Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 cycles min. Long Term – No Load 10x Cable diameter Short Term – Load 15x Cable diameter – –20°C to +70°C – –10°C to +60°C – –40°C to +80°C Type OFNR / OFN FT4 UL 1666 Passed Product Note: May be suitable for outdoor installations. Refer to Technical Advisory on page 66. Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Fiber Count M9X037 2 4.67 .184 19 13 7.0 2.8 4.7 1.8 801 180 M9X038 4 5.08 .200 24 16 7.6 3.0 5.1 2.0 867 195 M9X039 6 5.59 .220 28 19 8.4 3.3 5.6 2.2 1201 270 M9X040 8 5.97 .235 33 22 8.9 3.5 6.1 2.4 1201 270 M9X042 12 6.48 .255 40 27 9.6 3.8 6.6 2.6 1334 300 M9X601* 24 8.26 .325 63 42 12.4 4.9 8.4 3.3 1735 390 M9X602 24 12.60 .496 124 83 18.8 7.4 12.7 5.0 4270 960 M9X604 36 16.36 .644 204 137 24.6 9.7 16.5 6.4 6405 1440 M9X606 48 15.93 .627 195 131 23.9 9.4 16.0 6.3 4203 945 M9X609 72 19.10 .750 290 195 28.6 11.3 19.1 7.5 6005 1350 M9X622 96 22.73 .895 432 290 34.0 13.4 22.9 9.0 8820 1983 M9X619 144 24.49 .964 467 314 36.8 14.5 24.4 9.6 12,210 2745 For “X” in part number see optical characteristics on page 33. For Buffer and Inner Jacket colors see chart C on page 59. 34 MOHAWK Weight kg/km lbs/M' Part Number *Single jacket version. Plenum AdvanceLite® Distribution Plenum UL/c(UL) Type OFNP / OFN FT6 FIBER BUNDLE DETAIL Recommended Applications • Plenum or Riser cabling • Office cabling • Computer room cabling ARAMID STRENGTH ELEMENTS Product Features • 900 µm tight buffered fibers • Color coded for easy termination • Flame Retardant • UL listed for code compliance COLOR CODED JACKET OUTER JACKET SPECIFIED FIBER (COLOR CODED) 2-12 Fibers Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance UPJACKETED CENTRAL STRENGTH ELEMENT OVERALL POLYESTER TAPE BARRIER BUNDLES OF UP TO 12 FIBERS EACH >12-144 Fibers (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 cycles min. Long Term – No Load 10x Cable diameter Short Term – Load 15x Cable diameter – –20°C to +70°C – 0°C to +60°C – –40°C to +80°C Type OFNP / OFN FT6 UL 910 Passed Product Note: May be suitable for outdoor installations. Refer to Technical Advisory on page 66. Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M9X043 2 4.67 .184 21 14 7.0 2.8 4.7 1.8 801 180 M9X044 4 4.42 .174 19 13 7.0 2.8 4.7 1.8 867 195 M9X045 6 4.83 .190 24 16 7.6 3.0 5.1 2.0 1201 270 M9X046 8 5.64 .222 28 19 8.5 3.3 5.6 2.2 1201 270 M9X048 12 5.72 .225 33 22 8.6 3.4 5.8 2.3 1334 300 M9X611* 24 8.38 .330 60 40 12.4 4.9 8.4 3.3 1735 390 M9X612 24 12.52 .493 132 89 19.0 7.5 12.6 5.0 5618 1263 M9X614 36 15.09 .594 199 134 22.6 8.9 15.0 5.9 8509 1913 M9X616 48 15.21 .599 195 131 22.9 9.0 15.2 6.0 5538 1245 M9X620 72 19.15 .754 293 197 28.7 11.3 19.1 7.5 9310 2093 M9X623 96 22.96 .904 478 321 34.5 13.6 22.9 9.0 10,422 2343 M9X621 144 26.59 1.047 539 362 39.9 15.7 26.7 10.5 16,213 3645 For “X” in part number see optical characteristics on page 33. *Single jacket version. For Buffer and Inner Jacket colors see chart C on page 59. MOHAWK 35 LSZH AdvanceLite® Distribution Light Duty – Low Smoke Zero Halogen Riser UL/c(UL) Type OFNR / OFN FT4 Recommended Applications • Riser cabling • Office cabling • Computer room cabling LSZH JACKET ARAMID STRENGTH ELEMENTS Product Features • 900 µm tight buffered fibers • Color coded for easy termination • Flame Retardant • UL listed for code compliance SPECIFIED FIBER (COLOR CODED) Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 cycles min. Long Term – No Load 10x Cable diameter Short Term – Load 15x Cable diameter – –20°C to +70°C – –10°C to +60°C – –40°C to +80°C Type OFNR / OFN FT4 UL 1666 Passed Product Note: May be suitable for outdoor installations. Refer to Technical Advisory on page 66. Outside Diameter mm in. Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Fiber Count M9X100 2 4.7 .184 22 15 7.1 2.8 4.6 1.8 801 180 M9X101 4 5.1 .200 25 17 7.6 3.0 5.1 2.0 867 195 M9X102 6 5.6 .220 31 21 8.4 3.3 5.6 2.2 1201 270 M9X103 8 6.0 .235 36 24 8.9 3.5 6.1 2.4 1201 270 M9X104 12 6.5 .255 43 29 9.7 3.8 6.6 2.6 1334 300 For “X” in part number see optical characteristics on page 33. For Buffer colors see chart C on page 59. 36 MOHAWK Weight kg/km lbs/M' Part Number Riser & Plenum AdvanceLite® Ribbon Cables Riser UL/c(UL) Type OFNR / OFN FT4 Plenum UL/c(UL) Type OFNP / OFN FT6 Recommended Applications • Inter-equipment connections • NEBS applications OUTER JACKET Product Features • Color coded fibers • Suitable for use with standard ribbon connectors • Half-inch minimum bend radius • Tight center-to-center tolerances • Optional identification printing available • OFNR or OFNP Rated RIBBON FIBER Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Short Term Load • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance • UL/c(UL) Rated • Flame Resistance (EIA-455-41) (EIA-455-25) (EIA-455-104) Long Term – No Load Short Term – Load FOTP-33 – – – Type OFNR / OFN FT4 UL 1666 Type OFNP / OFN FT6 UL 910 2000 N/cm 2000 Impacts w/1.6 N-m 2000 cycles min. 10x Cable diameter 15x Cable diameter 100 lbs (444N) –20°C to +70°C 0°C to +60°C –40°C to +80°C Passed Passed Stocked items available! See page 58 for specific part numbers in our inventory. Riser Part Number Plenum Part Number Fiber Count Outside Diameter mm in. M9X630 M9X640 2 2.9 M9X631 M9X641 4 M9X632 M9X642 M9X633 M9X634 Weight kg/km lbs/M’ .114 7 5 2.0 x 2.9 .078 x .115 6 4 6 2.0 x 3.5 .078 x .137 9 6 M9X643 8 2.0 x 4.0 .078 x .158 9 6 M9X644 12 2.0 x 4.6 .078 x .180 10 7 For “X” in part number see optical characteristics on page 33. For Buffer colors see chart C on page 59. MOHAWK 37 Riser AdvanceLite® Breakout 2.0 mm sub-unit – Riser UL/c(UL) Type OFNR / OFN FT4 Recommended Applications • Riser cabling (typically under 300 meters) • Office cabling • Computer room cabling SUB-UNIT DETAIL OUTER JACKET ARAMID STRENGTH ELEMENTS Product Features • 900 µm tight buffered fibers • Color coded for easy termination • Flame Retardant • UL listed for code compliance • Direct connectorization • MSHA approved cables are available COLOR CODED THERMOPLASTIC JACKET 900 MICRON TIGHT BUFFERED FIBER 2.0 mm SUB-UNITS CENTRAL MEMBER Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 cycles min. Long Term – No Load 10x Cable diameter Short Term – Load 15x Cable diameter – –20°C to +70°C – –10°C to +60°C – –40°C to +80°C Type OFNR / OFN FT4 UL 1666 Passed Product Note: May be suitable for outdoor installations. Refer to Technical Advisory on page 66. Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Fiber Count M9X005 2 6.60 .260 36 24 9.9 3.9 6.6 2.6 1068 240 M9X006 4 8.15 .321 52 35 12.2 4.8 8.1 3.2 1535 345 M9X007 6 9.09 .358 80 54 13.6 5.4 9.1 3.6 2415 543 M9X008 8 10.29 .405 103 69 15.4 6.1 10.3 4.1 2700 600 M9X009 10 11.56 .455 128 86 17.3 6.8 11.5 4.5 2700 600 M9X010 12 13.06 .514 164 110 19.6 7.7 13.1 5.1 2700 600 M9X011 18 13.21 .520 155 104 19.8 7.8 13.2 5.2 2700 600 M9X012 24 14.99 .590 201 135 22.6 8.9 15.0 5.9 2700 600 M9X083 36 17.27 .680 250 168 25.9 10.2 17.3 6.8 2700 600 For “X” in part number see optical characteristics on page 33. For fiber counts 2 – 12 see chart C on page 59. For greater than 12 fibers, jackets are orange or aqua (MM) or yellow (SM) and numbered. 38 MOHAWK Max. Load (Installation) Newtons lbs. Part Number Plenum AdvanceLite® Breakout 2.0 mm sub-unit – Plenum UL/c(UL) Type OFNP / OFN FT6 Recommended Applications • Plenum and Riser cabling • Office cabling • Computer room cabling SUB-UNIT DETAIL OUTER JACKET ARAMID STRENGTH ELEMENTS Product Features • 900 µm tight buffered fibers • Color coded for easy termination • Flame Retardant • UL listed for code compliance • Direct connectorization COLOR CODED THERMOPLASTIC JACKET 900 MICRON TIGHT BUFFERED FIBER CENTRAL MEMBER 2.0 mm SUB-UNITS Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 cycles min. Long Term – No Load 10x Cable diameter Short Term – Load 15x Cable diameter – –20°C to +70°C – 0°C to +60°C – –40°C to +80°C Type OFNP / OFN FT6 UL 910 Passed Product Note: May be suitable for outdoor installations. Refer to Technical Advisory on page 66. Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M9X013 2 5.84 .230 30 20 8.9 3.5 5.8 2.3 801 180 M9X014 4 6.68 .263 45 30 9.9 3.9 6.6 2.6 1535 345 M9X015 6 7.85 .309 61 41 11.7 4.6 7.9 3.1 2068 465 M9X016 8 8.53 .336 82 55 13.0 5.1 8.7 3.4 2700 600 M9X017 10 9.78 .385 109 73 14.7 5.8 9.8 3.9 2700 600 M9X018 12 9.93 .391 89 60 15.0 5.9 9.9 3.9 2700 600 M9X019 18 11.58 .456 132 89 17.3 6.8 11.4 4.5 2700 600 M9X020 24 13.82 .544 174 117 20.6 8.1 13.7 5.4 2700 600 M9X082 36 15.54 .612 229 154 23.6 9.3 15.7 6.2 2700 600 For “X” in part number see optical characteristics on page 33. For fiber counts 2 – 12 see chart C on page 59. For greater than 12 fibers, jackets are orange or aqua (MM) or yellow (SM) and numbered. MOHAWK 39 Riser AdvanceLite® Breakout 2.5 mm sub-unit – Riser UL/c(UL) Type OFNR / OFN FT4 Recommended Applications • Riser cabling • Office cabling • Computer room cabling SUB-UNIT DETAIL Product Features • 900 µm tight buffered fibers • Color coded for easy termination • Flame Retardant • UL listed for code compliance • Direct connectorization • MSHA approved cables are available COLOR CODED THERMOPLASTIC JACKET Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance OUTER JACKET ARAMID STRENGTH ELEMENTS 900 MICRON TIGHT BUFFERED FIBER CENTRAL MEMBER 2.5 mm SUB-UNITS (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 cycles min. Long Term – No Load 10x Cable diameter Short Term – Load 15x Cable diameter – –20°C to +70°C – –10°C to +60°C – –40°C to +80°C Type OFNR / OFN FT4 UL 1666 Passed Product Note: May be suitable for outdoor installations. Refer to Technical Advisory on page 66. Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Fiber Count M9X021 2 7.62 .300 45 30 11.4 4.5 7.6 3.0 1068 240 M9X022 4 9.17 .361 64 43 13.7 5.4 9.1 3.6 1535 345 M9X023 6 10.67 .420 104 70 15.9 6.3 10.6 4.2 2700 600 M9X024 8 12.14 .478 135 91 18.2 7.2 12.1 4.8 2700 600 M9X025 10 13.72 .540 202 136 20.6 8.1 13.7 5.4 2700 600 M9X026 12 15.60 .614 220 148 23.4 9.2 15.6 6.1 2700 600 M9X027 18 15.75 .620 205 138 23.6 9.3 15.7 6.2 2700 600 M9X028 24 17.98 .708 271 182 26.9 10.6 18.0 7.1 2700 600 For “X” in part number see optical characteristics on page 33. For fiber counts 2 – 12 see chart C on page 59. For greater than 12 fibers, jackets are orange or aqua (MM) or yellow (SM) and numbered. 40 MOHAWK Max. Load (Installation) Newtons lbs. Part Number Plenum AdvanceLite® Breakout 2.5 mm sub-units – Plenum UL/c(UL) Type OFNP / OFN FT6 Recommended Applications OUTER JACKET SUB-UNIT DETAIL • Plenum and Riser cabling • Office cabling • Computer room cabling ARAMID STRENGTH ELEMENTS Product Features • 900 µm tight buffered fibers • Color coded for easy termination • Flame Retardant • UL listed for code compliance • Direct connectorization COLOR CODED THERMOPLASTIC JACKET 900 MICRON TIGHT BUFFERED FIBER CENTRAL MEMBER 2.5 mm SUB-UNITS Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 cycles min. Long Term – No Load 10x Cable diameter Short Term – Load 15x Cable diameter – –20°C to +70°C – 0°C to +60°C – –40°C to +80°C Type OFNP / OFN FT6 UL 910 Passed Product Note: May be suitable for outdoor installations. Refer to Technical Advisory on page 66. Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M9X029 2 6.88 .271 39 26 10.4 4.1 6.9 2.7 801 180 M9X030 4 7.72 .304 58 39 11.4 4.5 7.6 3.0 1535 345 M9X031 6 8.84 .348 82 55 13.2 5.2 8.9 3.5 2700 600 M9X032 8 10.36 .408 113 76 15.5 6.1 10.4 4.1 2700 600 M9X033 10 11.94 .470 149 100 17.9 7.1 11.9 4.7 2700 600 M9X034 12 11.96 .471 119 80 17.9 7.1 11.9 4.7 2700 600 M9X035 18 14.12 .556 179 120 21.1 8.3 14.2 5.6 2700 600 M9X036 24 16.94 .667 234 157 25.4 10.0 17.0 6.7 2700 600 For “X” in part number see optical characteristics on page 33. For fiber counts 2 – 12 see chart C on page 59. For greater than 12 fibers, jackets are orange or aqua (MM) or yellow (SM) and numbered. MOHAWK 41 Outdoor AdvanceLite® Loose Tube Outdoor Recommended Applications • Building interconnections and data trunk • Long haul networking • Ducts between buildings and aerial lashing • Applications requiring good ozone, moisture, weather resistance ARAMID STRENGTH ELEMENTS LOOSE TUBE DETAIL OUTER JACKET POLYETHYLENE MOISTURE BLOCKING GEL Product Features • All dielectric central strength member • Excellent attenuation performance • Dry water blocking for moisture protection • Polyethylene jacket for weather and UV protection • Breakout kits available (see page 53) • Waterblock gel available MULTIPLE 250 MICRON FIBERS THERMOPLASTIC TUBE CENTRAL E-GLASS STRENGTH MEMBER WATER BLOCKING TAPE Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m Long Term – No Load 15x Cable diameter Short Term – Load 20x Cable diameter – –40°C to +70°C – –30°C to +60°C – –50°C to +80°C Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Max. Load (Installation) Newtons lbs. Fiber Count Fibers Per Tube M9X510T 6 6 9.65 .380 65 44 19.3 7.6 14.5 5.7 2700 600 M9X511T 12 6 9.65 .380 65 44 19.3 7.6 14.5 5.7 2700 600 M9X500T 24 6 9.65 .380 67 45 19.3 7.6 14.5 5.7 2700 600 M9X502T 36 6 9.65 .380 70 47 19.3 7.6 14.5 5.7 2700 600 M9X505T 48 12 12.19 .480 104 70 24.4 9.6 18.3 7.2 2700 600 M9X507T 72 12 12.19 .480 104 70 24.4 9.6 18.3 7.2 2700 600 M9X513T 96 12 13.89 .547 138 93 27.7 10.9 20.8 8.1 2700 600 M9X509T 144 12 17.78 .700 222 149 35.6 14.0 26.7 10.5 2700 600 M9X520T 216 12 18.16 .715 220 148 36.3 14.3 27.2 10.7 2700 600 For “X” in part number see optical characteristics on page 33. See color chart C on page 59. 42 MOHAWK Min. Bend Radius Short Term Long Term cm in. cm in. Part Number Weight kg/km lbs/M' Armored AdvanceLite® Loose Tube Outdoor Direct Burial – Armored Recommended Applications • Building interconnections • Telecommunications and data trunk • Long haul networking • Direct burial and aerial lashing • Applications requiring good ozone, moisture, weather resistance WATER BLOCKING TAPE LOOSE TUBE DETAIL OUTER JACKET POLYETHYLENE MOISTURE BLOCKING GEL THERMOPLASTIC TUBE Product Features • Excellent attenuation performance • Dry water blocking for moisture protection • Polyethylene jacket for weather and UV protection • Breakout kits available (see page 53) • Corrugated Steel Tape • Rodent Resistant • Waterblock gel available INNER JACKET POLYETHYLENE MULTIPLE 250 MICRON CENTRAL E-GLASS ARAMID FIBERS STRENGTH STRENGTH MEMBER ELEMENTS CORRUGATED STEEL ARMOR Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m Long Term – No Load 15x Cable diameter Short Term – Load 20x Cable diameter – –40°C to +70°C – –30°C to +60°C – –50°C to +80°C Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count Fibers Per Tube M9X381T 6 6 13.46 .530 150 101 26.9 10.6 20.2 8.0 2700 600 M9X382T 12 6 13.46 .530 152 102 26.9 10.6 20.2 8.0 2700 600 M9X384T 24 6 13.46 .530 153 103 26.9 10.6 20.2 8.0 2700 600 M9X386T 36 6 13.46 .530 155 104 26.9 10.6 20.2 8.0 2700 600 M9X389T 48 12 16.51 .650 214 144 33.0 13.0 24.9 9.8 2700 600 M9X391T 72 12 16.51 .650 211 142 33.0 13.0 24.9 9.8 2700 600 M9X398T 96 12 17.53 .690 250 168 35.1 13.8 26.4 10.4 2700 600 M9X393T 144 12 22.10 .870 359 241 44.2 17.4 33.3 13.1 2700 600 M9X400T 216 12 22.10 .870 359 241 44.2 17.4 33.3 13.1 2700 600 Weight kg/km lbs/M' For “X” in part number see optical characteristics on page 33. See color chart C on page 59. MOHAWK 43 Loose Tube AdvanceLite® RiserLite ® Indoor/Outdoor – UL/c(UL) Type OFNR / OFN FT4 Recommended Applications • Indoor/outdoor installations • Telecommunications and data trunk • Building interconnections OUTER JACKET PVC MOISTURE BLOCKING GEL Product Features • No splicing required at building entrance • Available with zero-halogen jacket • Breakout kits available (see page 53) • Fully waterblocked MULTIPLE 250 MICRON FIBERS THERMOPLASTIC TUBE • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance CENTRAL E-GLASS STRENGTH MEMBER WATERBLOCKING TAPE Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance ARAMID STRENGTH ELEMENTS LOOSE TUBE DETAIL (EIA-455-41) (EIA-455-25) 2000 N/cm 2000 Impacts w/1.6 N-m Long Term – No Load 15x Cable diameter Short Term – Load 20x Cable diameter – –40°C to +70°C – –20°C to +60°C – –40°C to +80°C Type OFNR / OFN FT4 UL 1666 Passed Stocked items available! See page 58 for specific part numbers in our inventory. Part Number Fiber Count Fibers Per Tube Outside Diameter mm in. Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. M9X810 6 6 9.65 .380 94 63 19.3 7.6 14.5 5.7 2700 600 M9X811 12 6 9.65 .380 92 62 19.3 7.6 14.5 5.7 2700 600 M9X812 24 6 9.65 .380 91 61 19.3 7.6 14.5 5.7 2700 600 M9X813 36 6 9.65 .380 89 60 19.3 7.6 14.5 5.7 2700 600 M9X814 48 12 12.19 .480 132 89 24.4 9.6 18.3 7.2 2700 600 M9X815 72 12 12.19 .480 129 87 24.4 9.6 18.3 7.2 2700 600 M9X816 96 12 13.89 .547 170 114 27.7 10.9 20.8 8.2 2700 600 M9X817 144 12 17.78 .700 278 187 35.6 14.0 26.7 10.5 2700 600 For “X” in part number see optical characteristics on page 33. See color chart C on page 59. 44 MOHAWK Weight kg/km lbs/M' Loose Tube AdvanceLite® RiserLite ® Indoor/Outdoor Direct Burial/ Armored UL/c(UL) Type OFCR/OFC FT4 Recommended Applications • Indoor/outdoor building interconnections • Telecommunications and data trunk • Long haul networking • Direct burial and aerial lashing LOOSE TUBE DETAIL WATER BLOCKING TAPE OUTER JACKET PVC MOISTURE BLOCKING GEL Product Features • No splicing required at building entrance • Available with zero-halogen jacket • Breakout kits available (see page 53) • Fully waterblocked THERMOPLASTIC TUBE INNER JACKET PVC MULTIPLE 250 MICRON FIBERS CENTRAL E-GLASS STRENGTH MEMBER ARAMID STRENGTH ELEMENTS CORRUGATED STEEL ARMOR Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • Flame Resistance (EIA-455-41) (EIA-455-25) 2000 N-m 2000 Impacts w/1.6 N-m Long Term – No Load 15x Cable diameter Short Term – Load 20x Cable diameter – –40°C to +70°C – –20°C to +60°C – –40°C to +80°C Type OFCR / OFC FT4 1666 Passed Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count Fibers Per Tube M9X890 6 6 13.72 .540 205 138 27.4 10.8 20.6 8.1 2700 600 M9X891 12 6 13.72 .540 204 137 27.4 10.8 20.6 8.1 2700 600 M9X892 24 6 13.72 .540 202 136 27.4 10.8 20.6 8.1 2700 600 M9X893 36 6 13.72 .540 201 135 27.4 10.8 20.6 8.1 2700 600 M9X894 48 12 16.76 .660 262 176 33.5 13.2 25.1 9.9 2700 600 M9X895 72 12 16.76 .660 256 172 33.5 13.2 25.1 9.9 2700 600 M9X896 96 12 17.78 .700 307 206 35.6 14.0 26.7 10.5 2700 600 M9X897 144 12 22.35 .880 449 302 44.7 17.6 33.5 13.2 2700 600 Weight kg/km lbs/M' For “X” in part number see optical characteristics on page 33. See color chart C on page 59. MOHAWK 45 Plenum AdvanceLite® VersaLite™ Indoor / Outdoor UL/c(UL) Type OFNP / OFN FT6 Recommended Applications • Campus backbones • Interbuilding installations • Data centers • High density cable trays FIBER BUNDLE DETAIL OVERALL TAPE BARRIER OUTER JACKET ARAMID STRENGTH ELEMENTS Product Features • 2 to 144 fiber • Small diameter and bend radius facilitate installation in tight spaces • Fibers and subunits are color-coded for ease of identification • All-dielectric construction eliminates the need for grounding • Fibers grouped into sets of 12 for maximum density >12-144 FIBERS 12 FIBERS 250 µm COLOR CODED JACKET SPECIFIED FIBER (COLOR CODED) UPJACKETED CENTRAL STRENGTH ELEMENT BUNDLES OF UP TO 12 FIBERS EACH Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. (EIA-455-41) 250 N/cm (EIA-455-25) 2000 Impacts w/1.6 N-m (EIA-455-104) 2000 Cycles min. Long Term – No Load 15x Cable diameter Short Term – Load 20x Cable diameter – – – –40°C to +70°C 0°C to +60°C –40°C to +80°C Options • Available in 50 µm, 62.5 µm, single-mode, and hybrid constructions • Available in colored jackets for indoor only installations • Available with Interlock Armor Stocked items available! See page 58 for specific part numbers in our inventory. Outside Diameter mm in. Max. Load (Installation) Newtons lbs. Fiber Count Fibers Per Tube M9X202 6 6 6.7 .265 49 33 13.5 5.3 10.2 4.0 1423 320 M9X204 12 12 6.7 .265 49 33 13.5 5.3 10.2 4.0 1423 320 M9X205 24 12 9.12 .359 70 47 18.3 7.2 13.7 5.4 1801 405 M9X206 36 12 9.12 .359 70 47 18.3 7.2 13.7 5.4 1801 405 M9X207 48 12 9.12 .359 71 48 18.3 7.2 13.7 5.4 1801 405 M9X209 72 12 10.9 .429 107 72 21.8 8.6 16.3 6.4 3216 723 M9X211 96 12 12.73 .501 152 102 25.4 10.0 19.1 7.5 4017 903 M9X215 144 12 16.89 .665 284 191 33.8 13.3 25.4 10.0 5618 1263 For “X” in part number see optical characteristics on page 33. See color chart C on page 59. 46 MOHAWK Min. Bend Radius Short Term Long Term cm in. cm in. Part Number Weight kg/km lbs/M' Outside Plant AdvanceLite® Central Tube Outside Plant Recommended Applications • Campus OSP backbones • Drop cable • Telecommunications and data trunk OUTER JACKET STRENGTH MEMBER Product Features • Economical option for low fiber counts • Quick and easy end preparation • Fully waterblocked • No rods – easy handling BUFFER FIBER Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance (EIA-455-41) (EIA-455-25) • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. Long Term Short Term – – – BARRIER 250 N/cm 2000 Impacts w/1.6 N-m 15x Cable 20x Cable –40°C to +70°C –30°C to +60°C –40°C to +70°C Stocked items available! See page 58 for specific part numbers in our inventory. Outdoor Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M9X150 2 8.26 .325 52 35 16.5 6.5 12.45 4.9 2700 600 M9X151 4 8.26 .325 52 35 16.5 6.5 12.45 4.9 2700 600 M9X152 6 8.26 .325 52 35 16.5 6.5 12.45 4.9 2700 600 M9X153 8 8.26 .325 52 35 16.5 6.5 12.45 4.9 2700 600 M9X154 10 8.26 .325 52 35 16.5 6.5 12.45 4.9 2700 600 M9X155 12 8.26 .325 52 35 16.5 6.5 12.45 4.9 2700 600 Outdoor Armored Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M9X170 2 10.41 .410 101 68 20.8 8.2 15.6 6.15 2700 600 M9X171 4 10.41 .410 101 68 20.8 8.2 15.6 6.15 2700 600 M9X172 6 10.41 .410 101 68 20.8 8.2 15.6 6.15 2700 600 M9X173 8 10.41 .410 101 68 20.8 8.2 15.6 6.15 2700 600 M9X174 10 10.41 .410 101 68 20.8 8.2 15.6 6.15 2700 600 M9X175 12 10.41 .410 101 68 20.8 8.2 15.6 6.15 2700 600 For “X” in part number see optical characteristics on page 33. See color chart C on page 59. MOHAWK 47 Micro-Loose Tube ® AdvanceLite® Mini-tube – (900 µm) UL/c(UL) Type OFN / OFN FT1 UL/c(UL) Type OFNR / OFN FT4 Recommended Applications • Ducts between buildings • Telecommunications and data trunk OUTER JACKET POLYETHYLENE Product Features • Loose buffer dimensions compatible with standard connectors (900 µm) • Waterblock gel for moisture protection • Breakout kits not required for connectorization Mechanical & Environmental Characteristics • Crush Resistance (EIA-455-41) • Impact Resistance (EIA-455-25) • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. Long Term – No Load Short Term – Load – – – SUB-UNIT JACKET .098" (2.5 mm) MINI-TUBE 900 MICRON BUFFER GEL-FILLED 600 N/cm 20 Impacts w/1.0 N-m 15x Cable diameter UPJACKETED ARAMID STRENGTH ELEMENTS ARAMID STRENGTH ELEMENTS 20x Cable diameter –20°C to +70°C –20°C to +60°C –40°C to +70°C Outside Diameter mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M9X700 1 9.14 .360 64 43 18.3 7.2 13.7 5.4 1668 375 M9X701 2 9.14 .360 61 41 18.3 7.2 13.7 5.4 1535 345 M9X702 4 9.14 .360 58 39 18.3 7.2 13.7 5.4 1267 285 M9X703 6 10.62 .418 80 54 21.2 8.4 15.9 6.3 1801 405 M9X704 8 12.14 .478 113 76 24.3 9.6 18.2 7.2 2700 600 M9X705 12 15.60 .614 192 129 31.2 12.3 23.4 9.2 2700 600 M9X720 1 9.25 .364 79 53 18.5 7.3 14.0 5.5 1668 375 M9X721 2 9.25 .364 76 51 18.5 7.3 14.0 5.5 1535 345 M9X722 4 9.25 .364 73 49 18.5 7.3 14.0 5.5 1267 285 M9X723 6 10.72 .424 101 68 21.2 8.4 15.9 6.3 1801 405 M9X724 8 12.24 .482 115 77 24.3 9.6 18.2 7.2 2700 600 M9X725 12 15.70 .618 193 130 31.5 12.4 23.6 9.3 2700 600 M9X740 1 9.45 .372 85 57 18.8 7.4 14.2 5.6 1668 375 M9X741 2 9.45 .372 82 55 18.8 7.4 14.2 5.6 1535 345 M9X742 4 9.45 .372 76 51 18.8 7.4 14.2 5.6 1267 285 M9X743 6 10.97 .432 110 74 21.8 8.6 16.5 6.5 1801 405 M9X744 8 12.45 .490 140 94 24.9 9.8 18.8 7.4 2700 600 M9X745 12 15.90 .626 229 154 31.8 12.5 23.9 9.4 2700 600 For “X” in part number see optical characteristics on page 33. See color chart C on page 59. 48 MOHAWK AdvanceLite® ™ ArmorLite Heavy Duty Interlock Armored Riser – UL/c(UL) Type OFCR / OFC FT4 Plenum – UL/c(UL) Type OFCP / OFC FT6 Recommended Applications • Industrial environments • Rugged installations • Mining shafts • Telecommunications and data trunk • Replacement for innerduct INNER JACKET PVC OUTER JACKET PVC FIBER BUNDLE DETAIL ARAMID STRENGTH ELEMENTS Product Features • Excellent mechanical protection • Heavy duty construction • Eliminates need for innerduct • Versions available for outside plant • Colored armor available COLOR CODED JACKET SPECIFIED FIBER (COLOR CODED) CENTRAL E-GLASS STRENGTH MEMBER Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance (EIA-455-41) (EIA-455-25) • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) rated • Flame Resistance • UL/c(UL) Rated • Flame Resistance Long Term Short Term – – – Type OFCR / OFC FT4 UL 1666 Passed Type OFCP / OFC FT6 UL 910 Passed INTERLOCK ALUMINUM ARMOR BUNDLES OF UP TO 12 FIBERS EACH 2000 N/cm 2000 Impacts w/3 N-m 15x Cable 20x Cable –20°C to +70°C 0°C to +60°C –40°C to +70°C Stocked items available! See page 58 for specific part numbers in our inventory. Plenum Outside Diameter in. mm Weight lbs/M' kg/km Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M9X240 6 12.2 .481 134 90 24.4 9.6 18.3 7.2 1201 270 M9X241 12 12.85 .506 153 103 25.7 10.1 19.3 7.6 1334 300 M9X242 24 16.03 .631 225 151 32.0 12.6 24.1 9.5 1735 390 M9X243 24 19.84 .781 201 135 39.6 15.6 29.7 11.7 5618 1263 M9X244 36 22.38 .881 460 309 44.7 17.6 33.5 13.2 8509 1913 M9X245 48 22.38 .881 439 295 44.7 17.6 33.5 13.2 5538 1245 M9X246 72 26.19 1.031 644 433 52.3 20.6 39.4 15.5 9310 2093 M9X247 96 30.63 1.206 905 608 61.2 24.1 46.0 18.1 9608 2160 M9X248 144 33.81 1.331 1022 687 67.6 26.6 50.8 20.0 16213 3645 For “X” in part number see optical characteristics on page 33. For Buffer colors see chart C on page 59. MOHAWK 49 Simplex & Duplex AdvanceLite® 2.9 mm diameter – UL Type OFNR / c(UL) OFN FT4 UL Type OFNP / c(UL) OFN FT6 LSZH Recommended Applications • Patch cables • Short run office cabling • Computer room cabling • Other sizes available SIMPLEX .114" (2.9 mm) Mechanical, Environmental & Flame Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius • Min. Bend Radius • Operating Temp. • Installation Temp. • Storage Temp. • UL/c(UL) Rated • UL/c(UL) Rated • LSZH DUPLEX JACKET (EIA-455-41) (EIA-455-25) (EIA-455-104) Long Term – No Load Short Term – Load – – – Type OFNR / OFN FT4 Type OFNP / OFN FT6 200 N/cm 20 Impacts w/1.0 N-m 100 cycles min. 10x Cable diameter 15x Cable diameter –20°C to +70°C 0°C to +60°C –40°C to +70°C .233" (5.9 mm) 900 MICRON BUFFERED FIBER HEAVY DUTY DUPLEX .284" (7.2 mm) Stocked items available! See page 58 for specific part numbers in our inventory. Part Number Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Type Fiber Count M9X001 Simplex 1 9 6 4.3 1.7 2.9 1.1 400 90 M9X002 Duplex 2 18 12 4.3 1.7 2.9 1.1 801 180 M9X080 Heavy Duty Duplex 2 31 21 6.3 2.5 4.2 1.7 801 180 Simplex 1 9 6 4.3 1.7 2.9 1.1 400 90 M9X004 Duplex 2 19 13 4.3 1.7 2.9 1.1 801 180 M9X081 Heavy Duty Duplex 2 28 19 5.6 2.2 3.8 1.5 801 180 Weight kg/km lbs/M' Riser Plenum M9X003 For “X” in part number see optical characteristics on page 33. Low Smoke Zero Halogen M96436 Simplex 1 9 6 4.3 1.7 2.9 1.1 400 90 M98177 Duplex 2 19 13 4.3 1.7 2.9 1.1 801 180 M95890 Heavy Duty Duplex 2 34 23 6.3 2.5 4.2 1.7 801 180 LSZH Cables contain 62.5/125 grade 2 fiber. Also available with other fiber types. 50 MOHAWK Tactical Cables AdvanceLite® Fiber Optic Tactical Cables Recommended Applications • ENG vehicles • Outdoor events • Re-deployable communications • Digital camera transmission OUTER JACKET TIGHT BUFFERED FIBER Product Features • Rugged jacket • Durable design for repeated handling • Designed to military standards • Superior level of crush resistance ARAMID STRENGTH MEMBER Mechanical & Environmental Characteristics • Crush Resistance • Impact Resistance • Flexure • Min. Bend Radius (EIA-455-41) (EIA-455-25) 440 N/cm 200 Impacts w/2.2 N-m (EIA-455-104) 2000 Cycles min. 8x Cable diameter Long Term – No Load • Min. Bend Radius • Operating Temp. • Storage Temp. Short Term – Load (EIA-455-3) (EIA-455-3) 15x Cable diameter –55°C to +85°C –70°C to +85°C Stocked items available! See page 58 for specific part numbers in our inventory. Single-Mode Nominal OD mm in. Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M96566 2 5.3 .210 28 19 8.3 3.2 4.3 1.7 1468 330 M96639 4 5.7 .225 28 19 8.6 3.4 4.6 1.8 1468 330 M96567 6 6.1 .240 36 24 9.1 3.6 4.8 1.9 1468 330 M96568 8 6.3 .250 39 26 9.7 3.8 6.4 2.5 1468 330 M96569 10 6.7 .265 42 28 10.2 4.0 6.9 2.7 1468 330 M96570 12 6.5 .255 36 24 9.7 3.8 5.1 2.0 1468 330 Multimode (62.5/125 Grade 2) Nominal OD in. mm Weight kg/km lbs/M' Min. Bend Radius Short Term Long Term cm in. cm in. Max. Load (Installation) Newtons lbs. Part Number Fiber Count M96571 2 5.3 .210 28 19 8.3 3.2 4.3 1.7 1468 330 M96551 4 5.7 .225 28 19 8.6 3.4 4.6 1.8 1468 330 M96572 6 6.1 .240 36 24 9.1 3.6 4.8 1.9 1468 330 M96573 8 6.3 .250 39 26 9.7 3.8 6.4 2.5 1468 330 M96574 10 6.7 .265 42 28 10.2 4.0 6.9 2.7 1468 330 M96575 12 6.5 .255 36 24 9.7 3.8 5.1 2.0 1468 330 Additional optical fiber versions also available – contact factory. See optical characteristics on page 33. For buffer colors see chart C on page 59. MOHAWK 51 Optimax System ® Recommended Applications • • • • Field termination of cable Storage network connections Switch to fiber distribution Panel connections Product Features • • • • Pre-Polished Fiber Stub Does not require polishing paper; less craft-sensitive Safer, Simpler Installation No epoxy, curing equipment or power needed Precision Fiber Contact Pre-radiused PC ceramic ferrule assures durable contact and optimum mechanical performance Dramatic Reductions in: Installation Time; Cost of Equipment and Materials; Expertise/Training Required The Optimax Connectors are reliable field installable optical fiber connectors that are easy to install. They do not require epoxy, curing or polishing. Their unique design incorporates a factory polished fiber stub in a splice mechanism which provides a fast, secure, and reliable termination on optical fiber cables. All critical steps are performed in the factory, ensuring a superior-qualty connection every time. Only simple tools are required for installation, making Optimax a cost effective field termination. Optimax Connectors are high-quality LC, SC and ST Compatible connectors that use a ceramic ferrule with a physical contact (PC) polish for Multimode and super physical contact (SPC) polish for Single-mode that ensures the best possible mating of optical fibers. Connectors are available for 62.5 or 50/125 µm Multimode fiber and Single-mode fiber installations. Options • Field-installable Multimode ST-Type, SC or LC Fiber Optic Connectors Part Number Description A0408835 900µm 62.5/125 ST connector AX101075 900µm 50/125 ST connector AX101791 900µm Single-Mode ST connector AX101793 Additional parts for jacketed ST AX100029 900µm 62.5/125 SC connector AX101077 900µm 50/125 SC connector AX101792 900µm Single-Mode SC connector AX101794 Additional parts for jacketed SC AX101981 900µm 62.5/125 LC connector AX101982 900µm 50/125 LC connector AX101983 900µm Single-Mode LC connector AX101984 Additional parts for jacketed LC Optimax® Tool Kit Everything your field people need – and need to know – for expert installations is packaged in a small convenient carrying case: installation instructions and all the tools required to terminate 900 µm buffered optical fiber and jacketed fiber. Note: For installers already possessing basic fiber installation tools, dedicated tools can be purchased separately. Part Number 52 MOHAWK Description AX100947 Complete Tool Kit AX102062 Installation Tool LC (does not include tool-clamp) A0403634 Installation Tools ST Compatible & SC (Includes tool-clamp) A0408829 Cleaver Specifications Interconnection Compatibility: All ST-type, SC and LC connectors and compatibles Field Assembly Time: 1 minute for 900 µm fiber; 3 minutes for jacketed fiber Insertion Loss (Attenuation): 0.3 dB (typical) Durability: <0.2 dB change, 500 cycles multimode; <0.3 dB change, 500 cycles single-mode Nominal Fiber OD: 125 µm Operating Temperature: 0°C to +60°C (+32°F to +140°F) Storage Temperature: -40°C to +65°C (-40°F to +149°F) Tensile Strength: 12 lbs (54 N) Ferrule: Zirconia ceramic Reflectance: -30 dB (typical) multimode; -40 dB (guaranteed) single-mode Plug & Play Pre-Terminated Cables for Plug & Play Installations Recommended Applications • • Intrabuilding installations Data centers Product Features • • • 2 - 144 Fibers Maximum Density, Minimum Diameter Fibers are grouped in sets of 12. Small diameter and bend radius facilitate installation in tight spaces. Easy Identification and Installation Subunits are color-coded for identification. All-dielectric construction eliminates the need for grounding. Fibers terminated in MPO connectors. Mohawk’s unique data center assemblies combine compact size with industry standard MPO terminations to facilitate quick installations with maximum flexibility. Cable diameters are reduced by as much as 35% to save space in cable management pathways. The MPO terminations allow the cables to plug into a variety of manufacturers’ fiber cassettes which convert the MPO interface to an LC, SC, ST or other connector style. Factory terminations provide a pre-qualified high performance connection which removes the variability of field polishing from the link. All cables are plenum (OFNP) rated to allow them to be installed in any interior location. The fiber performance can be specified using Mohawk’s grading system to match the application. Hybrid cables, combining different fiber types, can also be specified. Options • • MD - X CCC - LLLF Available in 50 µm, 62.5 µm, singlemode, and hybrid constructions. Available in colored jackets. Part No. Example: MD - C 024 - 200F (Grade 5 24-fiber cable, 200 foot assembly) MD = Mini-Distribution Cable MA = Mini-Distribution Interlock Armor Cable X = Fiber Type CCC = Fiber Count (12 - 144) LLL = Length of Assembly (feet) (For “X” in part number see optical characteristics on page 33.) Breakout Kit This Field Breakout Kit is designed to attach to one tube of a loose tube cable and has either six or twelve 900 µm tubes that hold each of the coated fibers. For each end of the cable, one kit is needed for every tube. For example, part number M9B511T has two tubes with six 62.5/125 fibers each. This cable requires four field breakout kits; two for each end of the cable. The kit is available in two sizes to accommodate the two different tube sizes which are manufactured by Mohawk. For tubes containing one to six fibers, the diameter is 0.075" (1.9 mm) and for tubes containing seven to twelve fibers, the diameter is 0.110" (2.8 mm). Every kit is shipped with a complete set of instructions. Part Number Tube Diameter Fibers/Tube AX101100 0.075" (1.9 mm) ≤6 AX101101 0.110" (2.8 mm) 7-12 MOHAWK 53 Cross Reference Corning Cable Berk-Tek Mohawk Fiber Optic Cable Part # Cross Reference Fiber Size Riser Rated Patch Cables (OFNR) 001K31-31141-24 Corning Cable Berk-Tek Mohawk Fiber Size Riser Rated Distribution Cables (OFNR) continued ICR001CB3510/25 M92001 62.5/125 002K51-31141-24 ICR0X0CB3510/25 M95630 62.5/125 002K81-31130-24 ICR002CB3510/25 M9B037 62.5/125 001C31-31131-24 ICR001LB3520/55 M9A001 50/125 002C51-31131-24 ICR0X0LB3520/55 M9A002 002C81-31131-24 ICR002BB3520/55 001E31-31131-24 ICR001AB0707 002E51-31131-24 002E81-31131-24 004E81-31131-24 ICR004AB1010 M9W038 Single-Mode 006E81-31131-24 PDR006AB1010 M9W039 Single-Mode 008E81-31131-24 PDR008AB1010 M9W040 Single-Mode 012E81-33131-24 PDR012AB1010 M9W042 Single-Mode 50/125 024E81-33131-24 PDR024AB1010 M9W601 Single-Mode M9A037 50/125 036E81-61131-24 PDR6B036AB1010 M9W604 Single-Mode M9W001 Single-Mode 048E81-T3131-24 PDR12B048AB1010 M9W606 Single-Mode ICR0X0AB0707 M9W002 Single-Mode 072E81-T3131-24 PDR12B072AB1010 M9W609 Single-Mode ICR002AB0707 M9W037 Single-Mode 096E81-T3131-24 PDR12B096AB1010 M9W622 Single-Mode 144E81-T3131-24 PDR12B144AB1010 M9W619 Single-Mode Plenum Rated Patch Cables (OFNP) Plenum Rated Distribution Cables (OFNP) 001K38-31141-29 ICP001CB3510/25 M92003 62.5/125 002K58-31141-29 ICP0X0CB3510/25 M96232 62.5/125 004K88-31130-29 002K88-31130-29 ICP002CB3510/25 M9B043 62.5/125 001C38-31131-29 ICP001LB3520/55 M9A003 50/125 002C58-31131-29 ICP0X0LB3520/55 M9A004 002C88-31131-29 ICP002BB3520/55 001E38-31131-29 002E58-31131-29 002E88-31131-29 ICP004CB3510/25 M9B044 62.5/125 006K88-31130-29 PDP006CB3510/25 M9B045 62.5/125 008K88-31130-29 PDP008CB3510/25 M9B046 62.5/125 50/125 012K88-33130-29 PDP012CB3510/25 M9B048 62.5/125 M9A043 50/125 024K88-33130-29 PDP024CB3510/25 M9B611 62.5/125 ICP001AB0707 M93003 Single-Mode 036K88-61130-29 PDP6B036CB3510/25 M9B614 62.5/125 ICP0X0AB0707 M93004 Single-Mode 048K88-T3130-29 PDP12B048CB3510/25 M9B616 62.5/125 ICP002AB0707 M93043 Single-Mode 072K88-T3130-29 PDP12B072CB3510/25 M9B620 62.5/125 096K88-T3130-29 PDP12B096CB3510/25 M9B623 62.5/125 144K88-T3130-29 PDP12B144CB3510/25 M9B621 62.5/125 004C88-31131-29 ICP004LB3520/55 M9A044 50/125 006C88-31131-29 ICP006LB3520/55 M9A045 50/125 008C88-31131-29 ICP008LB3520/55 M9A046 50/125 012C88-33131-29 ICP012LB3520/55 M9A048 50/125 024C88-33131-29 ICP024LB3520/55 M9A611 50/125 036C88-61131-29 ICP6B036LB3520/55 M9A614 50/125 048C88-T3131-29 ICP12B048LB3520/55 M9A616 50/125 072C88-T3131-29 ICP12B072LB3520/55 M9A620 50/125 096C88-T3131-29 ICP12B096LB3520/55 M9A623 50/125 144C88-T3131-29 ICP12B144LB3520/55 M9A621 50/125 004E88-31131-29 ICP004AB1010 M9W044 Single-Mode 006E88-31131-29 PDP006AB1010 M9W045 Single-Mode 008E88-31131-29 PDP008AB1010 M9W046 Single-Mode 012E88-33131-29 PDP012AB1010 M9W048 Single-Mode 024E88-33131-29 PDP024AB1010 M9W611 Single-Mode 036E88-61131-29 PDP6B036AB1010 M9W614 Single-Mode 048E88-T3131-29 PDP12B048AB1010 M9W616 Single-Mode 072E88-T3131-29 PDP12B072AB1010 M9W620 Single-Mode 096E88-T3131-29 PDP12B096AB1010 M9W623 Single-Mode 144E88-T3131-29 PDP12B144AB1010 M9W621 Single-Mode Riser Rated Distribution Cables (OFNR) 004K81-31130-24 006K81-31130-24 ICR004CB3510/25 PDR006CB3510/25 M9B038 M9B039 62.5/125 62.5/125 008K81-31130-24 PDR008CB3510/25 M9B040 62.5/125 012K81-33130-24 PDR012CB3510/25 M9B042 62.5/125 024K81-33130-24 036K81-61130-24 PDR024CB3510/25 PDR6B036CB3510/25 M9B601 M9B604 62.5/125 62.5/125 048K81-T3130-24 PDR12B048CB3510/25 M9B606 62.5/125 072K81-T3130-24 PDR12B072CB3510/25 M9B609 62.5/125 096K81-T3130-24 144K81-T3130-24 PDR12B096CB3510/25 PDR12B144CB3510/25 M9B622 M9B619 62.5/125 62.5/125 004C81-31131-24 ICR004LB3520/55 M9A038 50/125 006C81-31131-24 PDR006LB3520/55 M9A039 50/125 008C81-31131-24 012C81-33131-24 PDR008LB3520/55 PDR012LB3520/55 M9A040 M9A042 50/125 50/125 024C81-33131-24 PDR024LB3520/55 M9A601 50/125 036C81-61131-24 PDR6B036LB3520/55 M9A604 50/125 048C81-T3131-24 072C81-T3131-24 PDR12B048LB3520/55 PDR12B072LB3520/55 M9A606 M9A609 50/125 50/125 096C81-T3131-24 PDR12B096LB3520/55 M9A622 50/125 144C81-T3131-24 PDR12B144LB3520/55 M9A619 50/125 54 MOHAWK Cross Reference Corning Cable Berk-Tek Mohawk Fiber Optic Cable Part # Cross Reference Fiber Size Corning Cable Berk-Tek Mohawk Fiber Size ArmorLite Plenum Rated Distribution Cables Plenum Rated Breakout Cables (OFNP) continued 006K88-31130-A3 PDPK006CB3510/25 M9B240 62.5/125 012K68-31330-29 HDP012CB3510/25 M9B018 62.5/125 012K88-33130-A3 PDPK012CB3510/25 M9B241 62.5/125 024K68-31330-29 HDP024CB3510/25 M9B020 62.5/125 024K88-33130-A3 PDPK024CB3510/25 M9B242 62.5/125 036K68-31330-29 HDP036CB3510/25 M9B082 62.5/125 006C88-31131-A3 PDPK006BB3520/55 M9A240 50/125 002C68-31331-29 HDP002BB3520/55 M9A013 50/125 012C88-33131-A3 PDPK012BB3520/55 M9A241 50/125 004C68-31331-29 HDP004BB3520/55 M9A014 50/125 024C88-33131-A3 PDPK024BB3520/55 M9A242 50/125 006C68-31331-29 HDP006BB3520/55 M9A015 50/125 006E88-31131-A3 PDPK006AB1010 M9W240 Single-Mode 008C68-31331-29 HDP008BB3520/55 M9A016 50/125 012E88-33131-A3 PDPK012AB1010 M9W241 Single-Mode 012C68-31331-29 HDP012BB3520/55 M9A018 50/125 024E88-33131-A3 PDPK024AB1010 M9W242 Single-Mode 024C68-31331-29 HDP024BB3520/55 M9A020 50/125 036C68-31331-29 HDP036BB3520/55 M9A082 50/125 002R68-31331-29 HDP002AB1010 M9W013 Single-Mode 004R68-31331-29 HDP004AB1010 M9W014 Single-Mode 006R68-31331-29 HDP006AB1010 M9W015 Single-Mode 008R68-31331-29 HDP008AB1010 M9W016 Single-Mode 012R68-31331-29 HDP012AB1010 M9W018 Single-Mode 024R68-31331-29 HDP024AB1010 M9W020 Single-Mode 036R68-31331-29 HDP036AB1010 M9W082 Single-Mode TM Riser Rated Breakout Cables (OFNR) 002K61-31330-24 004K61-31330-24 006K61-31330-24 HDR002CB3510/25 HDR004CB3510/25 HDR006CB3510/25 M9B005 M9B006 M9B007 62.5/125 62.5/125 62.5/125 008K61-31330-24 HDR008CB3510/25 M9B008 62.5/125 012K61-31330-24 HDR012CB3510/25 M9B010 62.5/125 024K61-31330-24 HDR024CB3510/25 M9B012 62.5/125 036K61-31330-24 HDR036CB3510/25 M9B083 62.5/125 002C61-31331-24 HDR002BB3520/55 M9A005 50/125 004C61-31331-24 HDR004BB3520/55 M9A006 50/125 002KW4-T3130A20 OPDD1B002CB3510/25 M9B058T 62.5/125 006C61-31331-24 HDR006BB3520/55 M9A007 50/125 004KW4-T3130A20 OPDD2B004CB3510/25 M9B063T 62.5/125 008C61-31331-24 HDR008BB3520/55 M9A008 50/125 006KW4-T3130A20 OPDD6B006CB3510/25 M9B510T 62.5/125 012C61-31331-24 HDR012BB3520/55 M9A010 50/125 008KW4-T3130A20 OPDD2B008CB3510/25 M9B065T 62.5/125 024C61-31331-24 HDR024BB3520/55 M9A012 50/125 012KW4-T3130A20 OPDD6B012CB3510/25 M9B511T 62.5/125 036C61-31331-24 HDR036BB3520/55 M9A083 50/125 018KW4-T3130A20 OPDD6B018CB3510/25 M9B512T 62.5/125 002R61-31331-24 HDR002AB1010 M9W005 Single-Mode 024KW4-T3130A20 OPDD6B024CB3510/25 M9B500T 62.5/125 004R61-31331-24 HDR004AB1010 M9W006 Single-Mode 036KW4-T3130A20 OPDD6B036CB3510/25 M9B502T 62.5/125 006R61-31331-24 HDR006AB1010 M9W007 Single-Mode 048KW4-T3130A20 OPDD12B048CB3510/25 M9B505T 62.5/125 008R61-31331-24 HDR008AB1010 M9W008 Single-Mode 072KW4-T3130A20 OPDD12B072CB3510/25 M9B507T 62.5/125 012R61-31331-24 HDR012AB1010 M9W010 Single-Mode 096KW4-T3130A20 OPDD12B096CB3510/25 M9B513T 62.5/125 024R61-31331-24 HDR024AB1010 M9W012 Single-Mode 144KW4-T3130A20 OPDD12B144CB3510/25 M9B509T 62.5/125 036R61-31331-24 HDR036AB1010 M9W083 Single-Mode 216KW4-T3130A20 OPDD12B216CB3510/25 M9B520T 62.5/125 002CW4-T3131A20 OPDD1B002BB3520/55 M9A058T 50/125 004CW4-T3131A20 OPDD2B004BB3520/55 M9A063T 50/125 006CW4-T3131A20 OPDD6B006BB3520/55 M9A510T 50/125 008CW4-T3131A20 OPDD2B008BB3520/55 M9A065T 50/125 012CW4-T3131A20 OPDD6B012BB3520/55 M9A511T 50/125 018CW4-T3131A20 OPDD6B018BB3520/55 M9A512T 50/125 Plenum Rated Breakout Cables (OFNP) 002K68-31330-29 HDP002CB3510/25 M9B013 62.5/125 004K68-31330-29 HDP004CB3510/25 M9B014 62.5/125 006K68-31330-29 008K68-31330-29 HDP006CB3510/25 HDP008CB3510/25 M9B015 M9B016 62.5/125 62.5/125 Loose Tube Cables This cross reference should be used in conjunction with Mohawk’s Fiber Optic section. It should be used for suggested alternative items which are functionally equal. Mohawk is not responsible for variances due to competitors’ construction changes. Consult your local Mohawk representative or the factory for items not listed or for special cable constructions. MOHAWK 55 Cross Reference Corning Cable Berk-Tek Mohawk Fiber Optic Cable Part # Cross Reference Fiber Size Loose Tube Cables continued Corning Cable Berk-Tek Mohawk Fiber Size Armored Loose Tube Cables continued 024CW4-T3131A20 OPDD6B024BB3520/55 M9A500T 50/125 048CW5-T3131A20 OPAD12B048BB3520/55 M9A389T 50/125 036CW4-T3131A20 OPDD6B036BB3520/55 M9A502T 50/125 072CW5-T3131A20 OPAD12B072BB3520/55 M9A391T 50/125 048CW4-T3131A20 OPDD12B048BB3520/55 M9A505T 50/125 096CW5-T3131A20 OPAD12B096BB3520/55 M9A398T 50/125 072CW4-T3131A20 OPDD12B072BB3520/55 M9A507T 50/125 144CW5-T3131A20 OPAD12B144BB3520/55 M9A393T 50/125 096CW4-T3131A20 OPDD12B096BB3520/55 M9A513T 50/125 216CW5-T3131A20 OPAD12B216BB3520/55 M9A400T 50/125 144CW4-T3131A20 OPDD12B144BB3520/55 M9A509T 50/125 002EW5-T3101A20 OPAD1B002AB0504 M9W358T Single-Mode 216CW4-T3131A20 OPDD12B216BB3520/55 M9A520T 50/125 004EW5-T3101A20 OPAD2B004AB0504 M9W363T Single-Mode 002EW4-T3101A20 OPDD1B002AB0504 M9W058T Single-Mode 006EW5-T3101A20 OPAD6B006AB0504 M9W381T Single-Mode 004EW4-T3101A20 OPDD2B004AB0504 M9W063T Single-Mode 008EW5-T3101A20 OPAD2B008AB0504 M9W365T Single-Mode 006EW4-T3101A20 OPDD6B006AB0504 M9W510T Single-Mode 012EW5-T3101A20 OPAD6B012AB0504 M9W382T Single-Mode 008EW4-T3101A20 OPDD2B008AB0504 M9W065T Single-Mode 018EW5-T3101A20 OPAD6B018AB0504 M9W383T Single-Mode 012EW4-T3101A20 OPDD6B012AB0504 M9W511T Single-Mode 024EW5-T3101A20 OPAD6B024AB0504 M9W384T Single-Mode 018EW4-T3101A20 OPDD6B018AB0504 M9W512T Single-Mode 036EW5-T3101A20 OPAD6B036AB0504 M9W386T Single-Mode 024EW4-T3101A20 OPDD6B024AB0504 M9W500T Single-Mode 048EW5-T3101A20 OPAD12B048AB0504 M9W389T Single-Mode 036EW4-T3101A20 OPDD6B036AB0504 M9W502T Single-Mode 072EW5-T3101A20 OPAD12B072AB0504 M9W391T Single-Mode 048EW4-T3101A20 OPDD12B048AB0504 M9W505T Single-Mode 096EW5-T3101A20 OPAD12B096AB0504 M9W398T Single-Mode 072EW4-T3101A20 OPDD12B072AB0504 M9W507T Single-Mode 144EW5-T3101A20 OPAD12B144AB0504 M9W393T Single-Mode 096EW4-T3101A20 OPDD12B096AB0504 M9W513T Single-Mode 216EW5-T3101A20 OPAD12B216AB0504 M9W400T Single-Mode 144EW4-T3101A20 OPDD12B144AB0504 M9W509T Single-Mode 216EW4-T3101A20 OPDD12B216AB0504 M9W520T Single-Mode Armored Loose Tube Cables 002KW5-T3130A20 004KW5-T3130A20 OPAD1B002CB3510/25 OPAD2B004CB3510/25 M9B358T 62.5/125 M9B363T 62.5/125 006KW5-T3130A20 OPAD6B006CB3510/25 M9B381T 62.5/125 008KW5-T3130A20 OPAD2B008CB3510/25 M9B365T 62.5/125 012KW5-T3130A20 018KW5-T3130A20 OPAD6B012CB3510/25 OPAD6B018CB3510/25 M9B382T 62.5/125 M9B383T 62.5/125 024KW5-T3130A20 OPAD6B024CB3510/25 M9B384T 62.5/125 036KW5-T3130A20 OPAD6B036CB3510/25 M9B386T 62.5/125 048KW5-T3130A20 072KW5-T3130A20 OPAD12B048CB3510/25 OPAD12B072CB3510/25 M9B389T 62.5/125 M9B391T 62.5/125 096KW5-T3130A20 OPAD12B096CB3510/25 M9B398T 62.5/125 144KW5-T3130A20 OPAD12B144CB3510/25 M9B393T 62.5/125 216KW5-T3130A20 002CW5-T3131A20 OPAD12B216CB3510/25 OPAD1B002BB3520/55 M9B400T 62.5/125 M9A358T 50/125 004CW5-T3131A20 OPAD2B004BB3520/55 M9A363T 50/125 006CW5-T3131A20 OPAD6B006BB3520/55 M9A381T 50/125 008CW5-T3131A20 012CW5-T3131A20 OPAD2B008BB3520/55 OPAD6B012BB3520/55 M9A365T 50/125 M9A382T 50/125 018CW5-T3131A20 OPAD6B018BB3520/55 M9A383T 50/125 024CW5-T3131A20 OPAD6B024BB3520/55 M9A384T 50/125 036CW5-T3131A20 56 MOHAWK OPAD6B036BB3520/55 M9A386T 50/125 RiserLite® Loose Tube Cables 006KWF-T4130A20 LTR6B006CB3510/25 M9B810 62.5/125 012KWF-T4130A20 LTR6B012CB3510/25 M9B811 62.5/125 024KWF-T4130A20 LTR6B024CB3510/25 M9B812 62.5/125 036KWF-T4130A20 LTR6B036CB3510/25 M9B813 62.5/125 048KWF-T4130A20 LTR12B048CB3510/25 M9B814 62.5/125 072KWF-T4130A20 LTR12B072CB3510/25 M9B815 62.5/125 096KWF-T4130A20 LTR12B096CB3510/25 M9B816 62.5/125 144KWF-T4130A20 LTR12B144CB3510/25 M9B817 62.5/125 006CWF-T4131A20 LTR6B006BB3520/55 M9A810 50/125 012CWF-T4131A20 LTR6B012BB3520/55 M9A811 50/125 024CWF-T4131A20 LTR6B024BB3520/55 M9A812 50/125 036CWF-T4131A20 LTR6B036BB3520/55 M9A813 50/125 048CWF-T4131A20 LTR12B048BB3520/55 M9A814 50/125 072CWF-T4131A20 LTR12B072BB3520/55 M9A815 50/125 096CWF-T4131A20 LTR12B096BB3520/55 M9A816 50/125 144CWF-T4131A20 LTR12B144BB3520/55 M9A817 50/125 006EWF-T4103A20 LTR6B006AB0504 M9W810 Single-Mode 012EWF-T4103A20 LTR6B012AB0504 M9W811 Single-Mode 024EWF-T4103A20 LTR6B024AB0504 M9W812 Single-Mode 036EWF-T4103A20 LTR6B036AB0504 M9W813 Single-Mode 048EWF-T4103A20 LTR12B048AB0504 M9W814 Single-Mode 072EWF-T4103A20 LTR12B072AB0504 M9W815 Single-Mode 096EWF-T4103A20 LTR12B096AB0504 M9W816 Single-Mode 144EWF-T4103A20 LTR12B144AB0504 M9W817 Single-Mode Cross Reference Corning Cable Berk-Tek Mohawk Fiber Optic Cable Part # Cross Reference Fiber Size RiserLite Armored Loose Tube Cables Corning Cable Berk-Tek Mohawk Fiber Size VersaLite Loose Tube Cables continued ® TM 006KWG-T3130A20 LTRA6B006CB3510/25 M9B890 62.5/125 - LTP12B072BB3520/55 M9A209 50/125 012KWG-T3130A20 LTRA6B012CB3510/25 M9B891 62.5/125 - LTP12B096BB3520/55 M9A211 50/125 024KWG-T3130A20 LTRA6B024CB3510/25 M9B892 62.5/125 - LTP12B144BB3520/55 M9A215 50/125 036KWG-T3130A20 LTRA6B036CB3510/25 M9B893 62.5/125 - LTP006AB0504 M9W202 Single-Mode 048KWG-T3130A20 LTRA12B048CB3510/25 M9B894 62.5/125 - LTP012AB0504 M9W204 Single-Mode 072KWG-T3130A20 LTRA12B072CB3510/25 M9B895 62.5/125 - LTP12B024AB0504 M9W205 Single-Mode 096KWG-T3130A20 LTRA12B096CB3510/25 M9B896 62.5/125 - LTP12B036AB0504 M9W206 Single-Mode 144KWG-T3130A20 LTRA12B144CB3510/25 M9B897 62.5/125 - LTP12B048AB0504 M9W207 Single-Mode 006CWG-T3131A20 LTRA6B006BB3520/55 M9A890 50/125 - LTP12B072AB0504 M9W209 Single-Mode 012CWG-T3131A20 LTRA6B012BB3520/55 M9A891 50/125 - LTP12B096AB0504 M9W211 Single-Mode 024CWG-T3131A20 LTRA6B024BB3520/55 M9A892 50/125 - LTP12B144AB0504 M9W215 Single-Mode 036CWG-T3131A20 LTRA6B036BB3520/55 M9A893 50/125 048CWG-T3131A20 LTRA12B048BB3520/55 M9A894 50/125 072CWG-T3131A20 LTRA12B072BB3520/55 M9A895 50/125 096CWG-T3131A20 LTRA12B096BB3520/55 M9A896 50/125 144CWG-T3131A20 LTRA12B144BB3520/55 M9A897 50/125 006RWG-T3101A20 LTRA6B006AB0504 M9W890 Single-Mode 012RWG-T3101A20 LTRA6B012AB0504 M9W891 Single-Mode 024RWG-T3101A20 LTRA6B024AB0504 M9W892 Single-Mode 036RWG-T3101A20 LTRA6B036AB0504 M9W893 Single-Mode 048RWG-T3101A20 LTRA12B048AB0504 M9W894 Single-Mode 072RWG-T3101A20 LTRA12B072AB0504 M9W895 Single-Mode 096RWG-T3101A20 LTRA12B096AB0504 M9W896 Single-Mode 144RWG-T3101A20 LTRA12B144AB0504 M9W897 Single-Mode VersaLiteTM Loose Tube Cables - LTP006CB3510/25 M9B202 62.5/125 - LTP012CB3510/25 M9B204 62.5/125 - LTP12B024CB3510/25 M9B205 62.5/125 - LTP12B036CB3510/25 M9B206 62.5/125 - LTP12B048CB3510/25 M9B207 62.5/125 - LTP12B072CB3510/25 M9B209 62.5/125 - LTP12B096CB3510/25 M9B211 62.5/125 - LTP12B144CB3510/25 M9B215 62.5/125 - LTP006BB3520/55 M9A202 50/125 - LTP012BB3520/55 M9A204 50/125 - LTP12B024BB3520/55 M9A205 50/125 - LTP12B036BB3520/55 M9A206 50/125 - LTP12B048BB3520/55 M9A207 50/125 Riser Rated Ribbon Cables 002KJ1-21140-0F - M9B630 62.5/125 004KJ1-41140-0F - M9B631 62.5/125 - M9B633 62.5/125 M9B634 62.5/125 008KJ1-81140-0F 012KJ1-T3140-0F RDR012CB3510/25 002CJ1-21111-0F - M9A630 50/125 004CJ1-41111-0F - M9A631 50/125 - M9A633 50/125 M9A634 50/125 008CJ1-81111-0F 012CJ1-T3111-0F RDR012BB3520/55 002RJ1-21131-0F - M9W630 Single-Mode 004RJ1-41131-0F - M9W631 Single-Mode 008RJ1-81131-0F - M9W633 Single-Mode 012RJ1-T3131-0F RDR012AB0707 M9W634 Single-Mode Plenum Rated Ribbon Cables 002KJ8-21140-0F - M9B640 62.5/125 004KJ8-41140-0F - M9B641 62.5/125 008KJ8-81140-0F - M9B643 62.5/125 M9B644 62.5/125 012KJ8-T3140-0F RDP012CB3510/25 002CJ8-21111-0F - M9A640 50/125 004CJ8-41111-0F - M9A641 50/125 008CJ8-81111-0F - M9A643 50/125 M9A644 50/125 012CJ8-T3111-0F RDP012BB3520/55 002RJ8-21131-0F - M9W640 Single-Mode 004RJ8-41131-0F - M9W641 Single-Mode 008RJ8-81131-0F - M9W643 Single-Mode 012RJ8-T3131-0F RDP012AB0707 M9W644 Single-Mode This cross reference should be used in conjunction with Mohawk’s Fiber Optic section. It should be used for suggested alternative items which are functionally equal. Mohawk is not responsible for variances due to competitors’ construction changes. Consult your local Mohawk representative or the factory for items not listed or for special cable constructions. MOHAWK 57 Fiber Optic Inventory Multimode Grade 2 62.5/125 Simplex/Duplex ..................p. 50 Riser Plenum M9B002 M9B004 Distribution ...........................p. 34 Riser Plenum M9B037 M9B043 M9B038 M9B044 M9B039 M9B045 M9B040 M9B046 M9B042 M9B048 M9B602 M9B611 M9B604 M9B612 M9B606 M9B616 M9B620 Ribbon ..................................p. 37 Plenum M9B644 ArmorLiteTM ............................p. 49 Plenum M9B240 M9B241 M9B242 Breakout ...............................p. 38 Riser Plenum M9B005 M9B013 M9B006 M9B015 M9B007 M9B010 RiserLite Indoor/Outdoor.........p. 44 ® Riser M9B810 M9B811 M9B812 Riser Armored M9B890 M9B891 VersaLiteTM Indoor/Outdoor........p. 46 Plenum M9B202 M9B204 M9B205 Loose Tube...........................p. 42 OSP OSP Armored M9B058T M9B363T M9B063T M9B381T M9B510T M9B382T M9B511T M9B384T M9B500T M9B502T M9B505T Central Loose Tube ..............p. 47 OSP M9B150 M9B152 M9B155 Mohawk’s inventoried fiber optic cables are listed here. Look for the part number you require under the appropriate grade of fiber to find if it is a stocked item.* Please consult the factory for quantities available. Multimode Grade 4 50/125 Multimode Grade 5 50/125 Simplex/Duplex ..................p. 50 Riser Plenum M9A002 M9A004 Simplex/Duplex ..................p. 50 Riser Plenum M9C002 M9C004 Distribution ...........................p. 34 Riser Plenum M9A037 M9A043 M9A038 M9A044 M9A039 M9A045 M9A048 M9A611 M9A612 M9A616 Distribution ...........................p. 34 Riser Plenum M9C037 M9C043 M9C038 M9C044 M9C039 M9C045 M9C042 M9C048 M9C611 M9C602 M9C604 M9C612 M9C616 ArmorLiteTM ............................p. 49 Plenum M9A240 M9A241 M9A242 M9A243 ArmorLiteTM ............................p. 49 Plenum M9C241 Breakout ...............................p. 38 Riser M9A007 M9A010 RiserLite® Indoor/Outdoor .......p. 44 Riser M9A810 M9A811 M9A812 VersaLite Indoor/Outdoor........p. 46 TM Plenum M9A202 M9A204 M9A205 Loose Tube...........................p. 42 OSP OSP Armored M9A510T M9A381T M9A511T M9A382T M9A500T M9A384T Central Loose Tube ..............p. 47 OSP M9A150 M9A152 M9A155 *Mohawk reserves the right to modify managed inventory items at any time with or without notice. 58 MOHAWK Breakout ...............................p. 38 Riser M9C007 M9C010 RiserLite® Indoor/Outdoor .......p. 44 Riser M9C810 M9C811 M9C812 VersaLiteTM Indoor/Outdoor........p. 46 Plenum M9C202 M9C204 M9C205 Loose Tube...........................p. 42 OSP OSP Armored M9C510T M9C381T M9C511T M9C382T M9C500T M9C384T Central Loose Tube ..............p. 47 OSP M9C150 M9C152 M9C155 Single-Mode Simplex/Duplex ..................p. 50 Riser Plenum M9W001 M9W004 M9W002 Distribution ...........................p. 34 Riser Plenum M9W037 M9W043 M9W038 M9W045 M9W039 M9W048 M9W042 M9W612 M9W602 M9W616 M9W604 M9W606 ArmorLiteTM ............................p. 49 Plenum M9W240 M9W241 M9W242 RiserLite® Indoor/Outdoor .......p. 44 Riser M9W810 M9W811 M9W812 VersaLiteTM Indoor/Outdoor........p. 46 Plenum M9W204 M9W205 Loose Tube...........................p. 42 OSP OSP Armored M9W510T M9W381T M9W511T M9W382T M9W500T M9W384T M9W502T M9W505T Central Loose Tube ..............p. 47 OSP M9W152 M9W155 Tactical Cable .......................p. 51 M96639 M96570 Color Code Charts Chart A Pair No. Chart C Pair Color Code 1 2 3 4 White/Blue & Blue White/Orange & Orange White/Green & Green White/Brown & Brown 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 Color Blue Orange Green Brown Slate White Fiber 7 8 9 10 11 12 Color Red Black Yellow Violet Pink Aqua Chart D Chart B Pair No. Fiber Pair Color Code White/Blue & Blue/White White/Orange & Orange/White White/Green & Green/White White/Brown & Brown/White White/Slate & Slate/White Red/Blue & Blue/Red Red/Orange & Orange/Red Red/Green & Green/Red Red/Brown & Brown/Red Red/Slate & Slate/Red Black/Blue & Blue/Black Black/Orange & Orange/Black Black/Green & Green/Black Black/Brown & Brown/Black Black/Slate & Slate/Black Yellow/Blue & Blue/Yellow Yellow/Orange & Orange/Yellow Yellow/Green & Green/Yellow Yellow/Brown & Brown/Yellow Yellow/Slate & Slate/Yellow Violet/Blue & Blue/Violet Violet/Orange & Orange/Violet Violet/Green & Green/Violet Violet/Brown & Brown/Violet Violet/Slate & Slate/Violet COLOR CODE REPEATS FOR EACH GROUP OF 25 PAIRS. For cables containing multiple groups of 25 pairs, each group will be identified by a color coded binder following the above color chart. Example: 50 pair cable will have 2 groups of 25 pairs; first binder color is white/blue, second binder is white/orange. Pair or Group Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Pair & Binder Color Code Tip Color Ring Color White White White White White Red Red Red Red Red Black Black Black Black Black Yellow Yellow Yellow Yellow Yellow Violet Violet Violet Violet Violet Blue Orange Green Brown Slate Blue Orange Green Brown Slate Blue Orange Green Brown Slate Blue Orange Green Brown Slate Blue Orange Green Brown Slate COLOR CODE REPEATS FOR EACH GROUP OF 25 PAIRS. For cables containing multiple groups of 25 pairs, each group will be identified by a color coded binder following the above color chart. Example: 50 pair cable will have 2 groups of 25 pairs; first binder color is white/blue, second binder is white/orange. MOHAWK 59 Insulations Comparative Properties of Insulations Property Considered Cellular Polyethylene Polyethylene Nylon G to E G to E P to F G F to G E Acid Resistance Abrasion Resistance Alcohol Resistance Polypropylene Polyurethane PVC FEP E F G to E E F to G O F to G G to E E E P E P G E G to E G to E E E F G E Benzol (Aromatic Hydrocarbons) Resistance P P G P to F P P to F E Degreaser Solvents (Halogenated Hydrocarbons) P P G P P P to F E Alkali Resistance Electrical Properties E E F E P to F F to G E Flame Resistance P P P P P E O Gasoline, Kerosene (Aliphatic Hydrocarbons) Resistance P to F P to F G P to F F P E Heat Resistance O G to E G E E G G to E Low Temperature Flexibility E G to E G P G P to G O Nuclear Radiation Resistance G G P to F F G P to G O Oil Resistance G to E G to E E E E P O Oxidation Resistance E E E E E E O Ozone Resistance E E E E E E E Water Resistance E E P to F E P E E Weather – Sun Resistance E E E E F to G G to E O P = Poor F = Fair G = Good E = Excellent O = Outstanding Above ratings are based on average performance of compounds. Any specific property can often be improved by the use of selective compounding. Current Carrying Capacity of Insulated Copper Conductors Amps PE, Polyurethane Polypropylene PVC PVC (Semi-Rigid) Nylon PVC PVDF PE (X-linked) Thermoplastic Elastomers Insulation Materials FEP Temperature Rating Nominal PVDF 6.4 Nylon 4.0 Polyester 2.80 Polyethylene (Cellular) 1.50 2.34 Size AWG 80°C 90°C 105°C 125°C 200°C Polyethylene (High Density) 30 2 3 3 3 4 Polyethylene (Low Density) 2.28 28 3 4 4 5 6 Polypropylene 2.24 26 4 6 5 6 7 Polyvinyl Chloride (Semi-Rigid) 4.3 24 6 7 7 8 10 Teflon FEP 2.15 2.15 22 8 9 10 11 13 Teflon TFE 20 10 12 13 14 17 Tefzel, Halar 2.6 24 FEP (Cellular) 1.5 18 15 17 18 20 16 19 22 24 26 32 14 27 30 33 40 45 12 36 40 45 50 55 10 47 55 58 70 75 8 65 70 75 90 100 6 95 100 105 125 135 4 125 135 145 170 180 2 170 180 200 225 240 Single Conductor in Free Air 30° Ambient Temp. 60 MOHAWK Dielectric Constants of Insulations UTP Installation Guide UTP cables were developed and designed to be used independent of the system application. Set transmission performance criteria (Categories) have been established for the various grades of UTP cables. What are these Categories? Categories are a method of classifying UTP cables and related hardware within specific performance criteria. Category 5e - Specifies cable and connecting hardware with transmission characteristics up to 100 MHz. It differs from Category 5 by having 3 dB tighter NEXT requirements and additional requirements for PS NEXT, ELFEXT, PS ELFEXT, and RL. Category 6 - This document specifies cable and connecting hardware with transmission characteristics up to 250 MHz. In addition Category 6 has tighter insertion loss, NEXT, PS NEXT, ELFEXT and PS ELFEXT over Category 5e. Cable Handling Length The maximum horizontal cable length is 90 meters (295 feet). Ten meters is allowed for cords in the work area, and for patch cords or jumpers in the telecommunications closet. The maximum backbone cable length is 90 meters (295 feet). This 90 meter length assumes that 5 meters (16 feet) are needed at each end for equipment cables connecting to the backbone. Pulling Tension Maximum pulling tension for a 4 pair horizontal cable is 25 lbf. Excessive pulling tensions may occur during installation. Once the damage is done, reversing the effect may not be sufficient enough to correct the problem and cable replacement is recommended. Intermediate cable pulls within the overall cable run may be necessary to avoid exceeding the maximum pulling force. Minimum Bend Radius 4 pair UTP cables have a 1” Min. Bend Radius. CAUTION: Exceeding the minimum bend radius can distort the cable geometry and result in degrading of transmission performance. Repositioning of the cable to the proper bend radii may not correct the fault. Once the damage is done, the best option is replacement of the damaged run. There are two common places where exceeding the minimum bend may occur: • At the workstation wall outlet. After the cable is terminated, too often the remaining cable is jammed into the wall outlet, or worse, wrapped around itself and shoved into the outlet. A better practice would be to gently work the excess cable length back through the wall outlet into the wall. • At the wiring closet, during routing of the cable to the terminal block or patch panel. Prior cable placement practices may have encouraged making the cable appear as formfitting or tight against the routing structure (cable tray or rack) as possible. A better practice would be to incorporate gently sweeping curves along the cable path avoiding sharp bends or changes in direction. Every effort should be made to ensure the path the cable follows has smooth gradual sweeps at any transition point. Installation in Temperatures Below Freezing The minimum installation temperature for plenum cables is 0° C (32° F). If the cable has to be installed when the temperature is below 32° F the following precautions should be taken to ensure that the jacket will not crack: • Store the cable in a heated area whose temperature is above 50° F for 24 hours before installation. • Transfer only enough cable to the job site for 4 hours work. The cable will retain enough heat to prevent cracking. Cable • Category 5e • Category 6 that has not been installed after 4 hours should be returned to a heated area. • Coil service loops in 10” to 12” loops. A tight coil could cause the cable to crack. • Normally the cables are terminated after the site is enclosed and heated. Do not attempt to terminate the cables when the temperature is below freezing. Over Stressing Eliminate cable stress caused by tension in suspended cable runs and tightly cinched cable bundles Excessive cable loading or stress can also occur if a cable is incorrectly suspended in a cable run. A recommended cable support spacing is 48" to 60" centers. Avoid twisting of cable during installation. Excessive twisting may result in distortion of cable geometry, and in severe cases tears in the jacket. In addition to the above guidelines extracted from TIA/EIA-568, Mohawk strongly recommends the following supplementary installation tips: • Do not walk or step on high performance cable. Do not run over high performance cable with hand trucks or forklifts. This will exert excessive force on the cable, distorting the geometry and/or crushing the pairs, resulting in electrical shorts. • Do not use staples, either from a staple gun or mounting in a traditional manner with a hammer. Staples can exert excessive force on the cable and distort the pair geometry. • D-Rings, nail on clamps or Velcro straps offer acceptable cable management techniques without compressing the cable. • Do not run cable near sources of heat, as this may negatively impact cable attenuation. • Maintain a 6" minimum spacing between cables and sources of EMI, such as fluorescent lights or unshielded power lines. Termination The installer must be acquainted with the Connector Manufacturer’s installation instructions. The correct tools, wire layout and untwist length are critical, especially in Category 6 installations. Modular jacks usually have the Pair color code marked on the jack. The color code can be either T568A or T568B wiring methods. Maintain the same pin to pair combination throughout the installation. Changing pin pair assignment can result in crossed pairs. Modular jacks and cross-connect blocks employ IDC connectors to complete the circuit between the cable and the hardware. The manufacturer will recommend the tools needed to terminate the cable. Terminate with connecting hardware of the same category or higher. Any link that has substituted a lower category component is automatically classified to that lower category. The maximum allowable amount of untwisting during cable termination to connecting hardware is 0.5" for Category 5e and Category 6 cables. Exceeding the recommended length of untwisting may cause performance problems. The same techniques should be employed when terminating crossconnect blocks. Maintaining jacket integrity to the point of termination aids in maintaining cable geometry and NEXT isolation from adjacent cable pairs. Bridged taps and splices are not permitted as part of copper horizontal cabling requirements. Testing It is best to determine the lengths of several representative cable runs and adjust the NVP to correspond to the known cable lengths. If the readout for the cable length is longer than the known length, the NVP should be decreased. Conversely, if the readout for the cable length is shorter than the known length the NVP should be increased. The NVP values for Mohawk’s products are as follows: Non-Plenum Plenum Category 5e 68% 72% Category 6 68% 72% A Note of Caution: Level II or Level III Testers will be required to accurately measure Category 5e and 6 permanent links and channels. Consult the manufacturer of your test set for clarification. Freq (MHz) 1.0 4.0 10.0 20.0 25.0 31.25 62.5 100.0 200.0 250.0 Freq (MHz) 1.0 4.0 10.0 20.0 25.0 31.25 62.5 100.0 200.0 250.0 Category 5e and 6 - Permanent Link Requirements at Specific Frequencies Insertion Loss NEXT 5e 6 5e 6 2.1 1.9 60.0 65.0 3.9 3.5 54.8 64.1 6.2 5.6 48.5 57.8 8.9 7.9 43.7 53.1 10.0 8.9 42.1 51.5 11.2 10.0 40.5 50.0 16.2 14.4 35.7 45.1 21.0 18.6 32.3 41.8 -27.4 -36.9 -31.1 -35.3 ELFEXT 5e 6 58.6 64.2 46.6 52.1 38.6 44.2 32.6 38.2 30.7 36.2 28.7 34.3 22.7 28.3 18.6 24.2 -18.2 -16.2 RL 5e 19.0 19.0 19.0 19.0 18.0 17.1 14.1 12.0 --- 6 19.1 21.0 21.0 21.0 19.5 18.5 16.0 14.0 11.0 10.0 The Permanent Link requirements include 90 meters of horizontal cable and the connectors at each end. The cables to the test equipment are not part of the permanent link and are subtracted out by the test equipment Channel requirements include 90 meters of horizontal cable and 10 meters of equipment cords, patch cords and jumpers. The maximum length of cross-connect jumpers and patch cords in the cross-connect facility should not exceed 5 meters. For additional information and an ANSI referenced list, please contact: GLOBAL ENGINEERING DOCUMENTS at 1-800-8547179. For additional information on cable selection, please call 1800-422-9961 or email to techsupport@mohawk-cable.com. These guides have been prepared by Mohawk as an aid for installers of Mohawk Category and Fiber Optic Cables and are not a warranty by Mohawk and should not be construed as such. Mohawk’s sole warranty with respect to its cables is set forth in the document entitled “Mohawk Warranty,” which has been or will be provided separately to installers of Mohawk Category and Fiber Optic Cables. MOHAWK 61 Fiber Installation Guide FOREWORD It is assumed that the reader has a general understanding of fiber optic cable constructions and terminology. BICSI (www.bicsi.org) is an excellent resource for general information. SAFETY PRECAUTIONS • When installed on a live system, invisible laser radiation may be present. Do not stare into connector endface or view directly with optical instruments. • Wear safety glasses when working with optical fiber. • Dispose of all scrap fibers to avoid getting fiber slivers. Scope The following guidelines are intended as a general overview of important issues related to the installation of fiber optic cable. INSTALLATION SPECIFICATIONS For a proper cable installation, it is important to understand the cable specification. The two most important specifications are the tensile loading and bend radius specifications. It is very important to adhere to these limits. Tensile loading Although there are two different types of tension in fiber optic cables, the important tension for the installation is the maximum load the cable can be subjected to without causing permanent damage. We call it the “maximum load installation” and it is measured in Newton or pounds. The “maximum load installation” can also be known as “short term tension”, “dynamic load”, “installation load” or “installation tension”. Whenever possible, the tension of the installation should be monitored. The tension can be measured with a dynamometer, or with a pulling wheel. Breakaway pulling eyes are available which separate if the tension reaches a preset level. The use of a swivel is recommended when pulling the cable in tray. The swivel allows the cable and pulling rope to twist independently. If pulling a cable in an outside plant conduit, the use of approved lubricants can help minimize friction. The use of corrugated innerducts can also help reduce the amount of tension needed to pull the cable. When installing 62 MOHAWK loose-tube cables, the use of sealer is recommended to prevent gel migration. If a run is too long, or if several bends are in the conduit, intermediate pull boxes should be used to separate one pull into two or more shorter pulls. A cable should not be pulled through more than two 90° bends at one time. If three or more 90° bends in a continuous run are unavoidable, the cable should be installed from a central point, unreeled into a figure-eight, and then backfed to complete the installation. Sharp bends may increase cable tension, so it is best to install cable in sequences that minimize stress and labor costs. When running cable vertically, take note of the cable weight. Install cables in a sequence that applies the least amount of strain on the cable. For example, most vertical chasers in buildings tend to be congested at the lower floors; instead, try to start your installation at the top and work down the building, thereby eliminating most of the cable installation by the time you reach the lower floors. After installation, the strength member of the cable will need to support the hanging cable. If a long vertical run is necessary, cable should be secured at each floor and service loops should be placed every three floors, at a minimum. This procedure will help distribute the weight of the cable vertically and will facilitate access to moves, adds and changes (MACs), if needed at a later date. Bend radius There are two types of bend radius: •The short term minimum bend radius, or dynamic bend radius, is the tightest recommended bend while installing cable at the maximum rated tension. It is the larger of the two specified bend radii. Throughout the pull, the minimum bend radius must be strictly followed. If a location exists in the middle of a run where a relatively tight bend is unavoidable, the cable should be hand-fed around the bend or a pulley can be used. •The long term bend radius, or static bend radius, is the tightest recommended bend while the cable is under a minimum tension. It is the smaller of the two specified bend radii. After the pull is complete, the cable can be bent more tightly to fit into existing space, but not to exceed the long term minimum bend radius. Figure 1: Bend Radius Table 1: Typical Bend Radius Specification Short Term (Installation) Long Term (Installed) Outside Plant Cable 20x Cable Diameter 15x Cable Diameter Premise Cable 10x Cable Diameter 15x Cable Diameter Always follow the manufacturer’s guidelines for minimum bend radius and tension. Failure to do so may result in high attenuation (macrobends) and possible damage to the cable and fiber. Guidelines are normally supplied with the cable manufacturer specification sheets. If the bend radius specifications are unknown, the industry de facto standard is to maintain a minimum radius of 20X the diameter of the cable. The minimum bend radius must also be adhered to when using service loops. Fiber optic splice trays and patch panels are designed to accommodate the bend radii of the individual fibers, but outside of the hardware, extra care must be taken. INSTALLATION TOOLS Gripping Techniques General To effectively utilize all of the available strength in the cable, the strength member must be used. The manufacturer’s specification will identify the strength member(s) in the cable. Cables with aramid yarn as the strength member For cables using aramid yarn alone as the strength member, the jacket can be removed exposing the aramid. The aramid should be tied in a knot with the pull rope, so that the jacket will not be inadvertently used for strength. Optionally, the jacket can be tied into a tight knot before pulling. After pulling, the knot should be cut off. Fiber Installation Guide Figure 2: Distribution Cable Tied in a Knot Cables with aramid yarn and an e-glass central member For cables using aramid yarn and an e-glass central member, a pulling grip should be used. The strength member(s) should be attached independently. This can be accomplished by weaving the strength member into the fingers of the grip, and then taping it together. All strength members should be gripped equally to ensure a proper distribution of tension. Figure 3: Pulling Grip Pre-terminated Fiber Optic Cable Assemblies General The factory pre-terminated fiber optic cable assemblies may be specified in project environments such as Data Centers. The assemblies can be ordered in either indoor (plenum) or outdoor versions, and different fiber counts, and in multimode or single-mode. A pulling eye can be factory installed on either end or on both ends of the cable. The pulling eye (and associated cable netting) will protect the pre-terminated ends during the pull. This product is a great time saver ensuring quality connections every time. Pulling eye The pulling eyes (and associated cable netting) are highly recommended. The pulling eye will facilitate the installation as well as protecting the pre-terminated ends during the pull. For both regular and pre-connectorized cables, the maximum pull force is identified with the “installation maximum load” cable specification on our Datasheets. In many cases, pulling is not done from point to point, but rather from an intermediate point pulling back in each direction to each termination location. It is then important to make sure that the cable is ordered with two pulling eyes, one at each end. The installation of a cable, which is preconnectorized on both ends, requires special raceway considerations and pulling grips. A typical fiber optic connector is 0.5 in. (1.25 cm) in diameter, has a limited pull-off rating and must be protected during cable placement. A pulling grip for a pre-connectorized cable must successfully isolate the connectors from any tensile load by placing the load on the cable itself. The pulling grip must also protect the connectors from abrasion and damage. In medium fiber counts (6 to 24 fibers) the connectors must be staggered when installed to reduce the diameter of the pulling grip. In highfiber counts (greater than 24 fibers), installation of a connectorized cable may not be possible due to the conduit size that would be required. ensure that the jacket will not crack: INSTALLATION GUIDELINES OUTSIDE PLANT CABLE INSTALLATION Prior to installation All optical fiber cables are tested before leaving our manufacturing plant. Before installing the cable, we recommend testing the cable on the reel for continuity. This is to ensure that no damage occurred during shipment. Since the cost of installation is usually higher than the cost of materials, testing the fibers before installation can avoid unnecessary additional expenses and help meeting important deadlines. At a minimum, continuity testing can be done on the reel with a visual fault locator or a simple fiber tracer such as a flashlight, a modified flashlight to properly hold the fibers, a microscope or a bright red light (LED lookalike). With this simple test, you should be able to identify broken fibers, if any, within the optical fiber cable. Also, it is recommended to double-check the actual fiber count and the actual cable length, to avoid any inconvenience. It is preferable to use Velcro wraps instead of tie-wraps. Remember not to distort the shape of the cable, as this adds pressure onto the optical fibers and may affect performance. Fiber optic cables can be installed in innerducts. The use of innerducts tends to reduce the pulling tension required. Ensure that the properly rated innerduct is being installed. A 3 to 6 m (10 to 20 ft) of cable slack should be stored in enclosure or on the wall to allow repairs and/or relocation needs. Installation in Temperatures Below Freezing • Store the cable in a heated area whose temperature is above 50° F for 24 hours before installation. • Transfer only enough cable to the job site for 4 hours work. The cable will retain enough heat to prevent cracking. Cable that has not been installed after 4 hours should be returned to a heated area. • Coil service loops in 10” to 12” loops. A tight coil could cause the cable to crack. • Normally the cables are terminated after the site is enclosed and heated. Do not attempt to terminate the cables when the temperature is below freezing. General Protect exposed cables from vehicular and public traffic. Underground Installation For underground installation, center pull long cables. Store excess cable in vaults and manholes, and identify optical cables with markers. Aerial Installation Use proper hardware matching cable, span and tension requirements. Use correct cable jacket. Buried Cable Installations Identify cable locations with surface markers. Anticipate obstructions. Administration A unique identifier shall be assigned to each backbone cable and shall be marked on each end. Reference should be made as per the ANSI/TIA/EIA-606-A standard. TERMINATION General Before termination, the cable should be properly secured to provide a tension-free length of fiber. When splicing fibers, mechanical or fusion, a splice tray is needed to properly store the completed splices. If connectors are to be used, trays or shelves should be used to support the fiber behind the connector. Proper strain relief sleeves provided with the connectors should always be used to prevent excessive bending of fiber. No shelf is necessary if terminating a breakout style cable with connectors. The minimum installation temperature for plenum cables is 0° C (32° F). If the cable has to be installed when the temperature is below 32° F the following precautions should be taken to MOHAWK 63 Fiber Installation Guide CABLE PREPARATION FOR THE TERMINATION General It is acceptable to directly terminate the 900 µm tight buffer from a distribution cable with a connector, if the above precautions are taken. It can be acceptable to directly terminate the 250 µm coated fiber from a loose buffer tube with a connector in certain applications. However, it is usually recommended to use a breakout kit which converts a six or twelve fiber loose buffer tube to a six or twelve fiber 900 µm distribution style ready for termination. If outside plant cables are used, the gel flooding material needs to be cleaned with the appropriate solvent (please consult the cable manufacturer for recommendation on the choice of solvent). The more thorough the cleaning, the easier the termination procedure will be. Cable preparation To prepare the cable for termination, the outer jacket must be properly stripped. Two ring cuts should be made in the jacket; one about 2” from the end and the second at the point where the jacket is to be removed. Care must be taken not to cut all the way through the jacket and into the core. The 2” piece is removed from the end of the cable exposing the core and the aramid ripcord. Make a notch in the jacket alongside the ripcord (do not cut the ripcord!). Pull the ripcord with a needle-nose pliers, or similar, until it reaches the second ring cut. Remove the core from the sliced jacket and pull the jacket to tear it at the ring cut. Once the fiber optic cable is ready for termination, follow the termination installation instructions. TESTING General Once the cable plant is installed and terminated, it is recommended to test the fiber optic segment. The testing should be done according to TIA TSB-140. This document provides guidelines for field-testing length, loss and polarity of a completed fiber optic link. It is necessary to perform an end-to-end attenuation test to verify the quality of installations and to ensure high quality system 64 MOHAWK performance. The best way to verify whether an end-to-end link meets the link loss budget is to divide the end-to-end link into segments at each cross-connect and measure the attenuation of each link segment. In order for the system to operate properly, the sum of the attenuation for the multiple link segments that form an end-toend link must be less than the link loss budget calculated in the design phase. Test equipment Various types of testing equipment are available on the market, such as Optical Loss Test Set (OLTS), Visual Fault Locator (VFL) sets or the Optical Time Domain Reflectometer. For troubleshooting, the OTDR is recommended. Optical Loss Test Set (OLTS) The OLTS consists of a light source and an optical power meter. The main function of this equipment is to measure the optical power or loss. Visual Fault Locator (VFL) or tracer The VFL is a red laser source; the tracer is an LED source. Either instrument can be used to trace fibers and troubleshoot faults on optical fiber cables. The main function of this equipment is to check continuity of the fiber, as well as to identify fibers and connectors in patch panels or outlets. Optical Time Domain Reflectometer (OTDR) The OTDR is a more sophisticated measurement instrument. It uses a technology that injects a series of optical pulses into the fiber under test and analyzes the light scattering and the light reflection. This allows the instrument to measure the intensity of the return pulse in functions of time and fiber length. The OTDR is used to measure the optical power loss and the fiber length, as well as to locate all faults resulting from fiber breaks, splices or connectors. Fiber testing guidelines The following testing guidelines promote efficient and accurate testing: • Clean all connections and adapters at the optical test points prior to taking measurements, as per ANSI/TIA/EIA-526-14A. • The light source or OTDR (Optical Time Domain Reflectometer) must operate within the range of 850 ± 30 nm, or 1300 ± 20 nm for multimode testing. • Test jumpers must be of the same fiber core size, performance and connector type as the cable system (e.g., 50/125 µm jumpers for a 50/125 µm optical fiber system) and shall be one to five meters long. ANSI/TIA/EIA-568-B.1 is the recommended test method. Every reel of fiber optic cable shipped from Mohawk has a test report attached showing the attenuation of all the fibers in the cable. Typical values for a multimode cable are 2.7 dB/km when measured at 850 nm and 0.7 dB/km when measured at 1300 nm. Therefore, for a run of 100 meters (328 feet), the typical cable attenuation is only 0.27 dB at 850 nm and 0.07 dB at 1300 nm. Most fiber optic connectors are specified as having an insertion loss of less than 0.5 dB. Since there are two connections for each fiber, up to 1 dB of attenuation can be expected to be added to the installed cable. As the cable runs get shorter, the cable attenuation becomes lower, but the connector insertion loss remains the same. If the cable is installed properly, most of the measured attenuation will come from the connectors. If several fibers off of the same cable show high attenuation, or if a single fiber attenuation remains high after retermination, an OTDR should be used to isolate the problem. An OTDR is an excellent tool for troubleshooting a failing link by identifying the location of the faulty component. These guides have been prepared by Mohawk as an aid for installers of Mohawk Category and Fiber Optic Cables and are not a warranty by Mohawk and should not be construed as such. Mohawk’s sole warranty with respect to its cables is set forth in the document entitled “Mohawk Warranty,” which has been or will be provided separately to installers of Mohawk Category and Fiber Optic Cables. Slide Guides LAN Cable Selector Guide Multimode Fiber Grade Selector Plenum & Non-Plenum Conduit Fill Guide Match your application to the corresponding cable category. Use the selector guide to determine which copper product best suits your needs. From legacy 10BASE-T to Gigabit Ethernet to emerging networking protocols, the applications are identified. Worst-case performance is stated at two frequencies for all categories of performance, from minimally compliant Category 5e to our Category 6A GigaLAN 10. Short Wavelength or Long Wavelength, 50/125 micron or 62.5/125 micron, we have a solution for you. Mohawk has designed our Fiber Grade Selector to help you determine which multimode fiber type best suits your application. Legacy installations to emerging networking protocols are identified and the guaranteed performance of each fiber is given along with the appropriate optical specifications. This rotary style guide lets you determine the number of cables, from Category 3 to Augmented Category 6, that will fill a trade size conduit. Either plenum or non-plenum. MOHAWK 65 Technical Advisory Fiber Optic Cables Tight Buffer for Outdoor Considerations There are two standard types of fiber optic cables for data/voice communications: tight buffered and loose tube. As a rule, tight buffered cables are used indoors (intrabuilding, premise) and loose tube cables are used outdoors (interbuilding, outside plant). Loose tube cables should be utilized in outside plant installations whenever possible, due to their long history with the various telephone companies, superior UV resistance, and exceptional resistance to moisture. Many studies have shown that the long term reliability of optical fiber is highest when the fiber is contained in a loose tube design. Loose tube cables may be ordered in a “dry block” version for easier termination, thus avoiding the gel flooding which some consider to be a problem. Tight buffered cables utilize a 900 µm buffer over each individual fiber to provide ease of handling and a color code. These cables typically have a flame retardant jacket, such as PVC, in order to meet the code requirements necessary for installation in a building. The combination of the tight buffers with the PVC jacket results in a flexible design that is easy to work with. When used in an outdoor environment, a tight buffer cannot provide the same level of protection to the optical fiber as a loose tube. 66 MOHAWK RiserLite® cables are designed to bridge the gap between standard loose tube and tight buffered cables. RiserLite cables are gel-filled, “dry blocked” loose tube cables which allow them to be installed in outdoor applications. They also have a UL OFNR and c(UL) OFN FT4 rating, which allows them to be installed in the building riser, as well. Many installers prefer to use tight buffered cables in the outside plant because of the relative ease of termination. If tight buffered cable is to be used in an outside environment, then special care must be taken. The cable must not be installed in aerial lashed, self-support, or direct buried applications. The cable must be installed below the frost line and in a “dry” conduit. As an alternative, a product from American Polywater (www.polywater.com) called “IceFree” can help keep the conduit dry and prevent water from freezing and damaging the fiber. Proper pulling techniques must also be followed, as tight buffered cables typically have lower pulling tensions than loose tube cables. If questions arise concerning a particular application, call the Technical Support Group of Mohawk at (800) 422-9961. MAC Certification MAC Warranty Program MAC Warranty Program Several years ago Mohawk developed a standards based BiCSi accredited training program. This program is geared primarily towards contractors, but is also offered to consultants and end-users. After successfully completing the training program the individual is eligible to receive 7 BiCSi credits. The Mohawk ChannelMATE® Cabling System Warranty period offered by a MAC is from 15 years to lifetime. It encompasses Mohawk’s copper products from Category 5e through Augmented Category 6, including high pair count cables, copper backbone, and all fiber optic cables. There are two options available to become a Mohawk Accredited Contractor (MAC). First, you may elect to be trained by one of Mohawk’s on staff RCDD instructors. This would enable you to be eligible to receive the 7 BiCSi credits. Second, you may choose to be grandfathered into the MAC program by having successfully completed an approved training program offered by one of our connectivity partners. Additional benefits of being a MAC contractor include the backing of Mohawk’s comprehensive technical support group for product information, installation troubleshooting and industry updates on the latest standards and applications guidelines. MAC contractors may also be eligible for a product rebate based on their qualified purchases. All backed by the strength of Belden’s financial and managerial resources. The major benefit of being a MAC is to enable the contractor to offer an extended warranty to the enduser on Mohawk products. MOHAWK 67 Packaging Color Coded Cartons for Ease of Category Identification Easybox™ For Category 3–6e+ UTP Cables Cable Caddy™— Reel-in-a-box For Category 3–6e+ UTP Cables The cable is packaged directly in the box and dispenses in a tangle-free payout, as if on a reel, in 1000 ft. lengths. The 1000 ft. length of cable is placed on a plastic reel and is dispensed from the front of the Cable Caddy. Reels Fiber Optic Cables Mohawk’s standard UTP and ScTP copper cables are available on 1000 ft. reels from inventory. Nonstandard cables are available in customer specified lengths as well as 1000 ft. reels. Mohawk’s fiber optic cable is supplied on reels only and is available in specified lengths with a –0+10% tolerance on standard size reels. Non-standard putups are available on request. Category 3–6e+ cables are also available on standard 1000 ft. reels. Smart Legend® Mohawk’s Smart Legend designation has been implemented to assist installers with cable identification. A serial number is printed every two feet Part Number Lot Code Sequential Footage Serial on all 4 pair cables (excluding OSP Marker Number cables) at final packaging. This allows for easy identification of reels, saving installers the time of labeling each run. For multiple runs off the same spool, only the addition of a single-character identifier is required, saving time wasted on a lengthy identification scheme. 68 MOHAWK Shipping & Packaging Guide ® ® Augmented Cat 6 • GigaLAN10 Cat 5e 5e LAN • Cat 5E+ MegaLAN TM Package Number Per Pallet Size of Pallet Package Number Per Pallet Size of Pallet 12” Reels 60 38” X 48” 18” Reels 15 44” X 44” Boxes 36 44” X 44” 36 38” X 48” Package 16” Number Per 27 Pallet Size 48”ofXPallet 48” 45 42” X 48” 18” 15 44” X 44” 20” 8 42” X 42” Size of Pallet 22” 8 42” X 42” 24” 8 48” X 48” (13& k ”W x 10! f ”D x 12! s ”H) Reel in a Box (11& k ”W x 11# k ”D x 11& k ”H) 5e PVC Box (14! f ”W x 14! f ”D x 7% k ”H) TM Additional Reel Sizes ® Cat 6 6 LAN • Cat 6e AdvanceNet Number Per Package Cat 6e+ GigaLAN Pallet ® 14” Reels 36 42” X 42” Boxes 33 45” X 48” 27 42” X 42” (15! s ”W x 11! f ”D x 14! f ”H) Reel in a Box (12# f ”W x 12# f ”D x 12& k ”H) High Pair Count Reel Put-ups Cat 3 Non-Plenum Gross Weight 50 pair 20” Reel 1000 ft 123 lbs 22” Reel 1000 ft 224 lbs 30” Reel 1000 ft 467lbs 24” Reel 2000 ft 246 lbs 30” Reel 2000 ft 455 lbs 36” Reel 2000 ft 950 lbs 36” Reel 5000 ft 620 lbs 48” Reel 5000 ft 1,160 lbs 42” Reel 2500 ft 1,167 lbs 36” Reel 6500 ft 805 lbs 48” Reel 4000 ft 1,910 lbs 54” Reel 5000 ft 2,400 lbs 25 pair Gross Weight Gross Weight 100 pair Cat 3 Plenum 200 pair Gross Weight 300 pair Gross Weight 400 pair Gross Weight 48” Reel 1000 ft 1,897 lbs 54” Reel 1000 ft 1,900 lbs 72” Reel 2000 ft 3,900 lbs 42” Reel 1000 ft 814 lbs 54” Reel 2000 ft 1,680 lbs 54” Reel 2000 ft 2,800 lbs 72” Reel 5000 ft 4,300 lbs 60” Reel 3000 ft 4,200 lbs 72” Reel 4000 ft 5,600 lbs 25 pair Cat 5 & 5e Power Sum Plenum Gross Weight Riser Gross Weight 22” Reel 1000 ft 131 lbs 24” Reel 1000 ft 119 lbs 30” Reel 2000 ft 262 lbs 36” Reel 2000 ft 245 lbs 36” Reel 5000 ft 655 lbs 48” Reel 5000 ft 640 lbs MOHAWK 69 Locator Mohawk P/N Page M52995 .......................15 M53639 .......................21 M54568 .......................15 M54708 .......................21 M54783 .......................21 M54785 .......................15 M54998 .......................15 M55073 .......................23 M55082 .......................21 M55211 .......................23 M55212 .......................23 M55216 .......................23 M55436 .......................15 M55477 .......................15 M55530 .......................15 M55586 .......................15 M55700 .......................23 M55704 .......................23 M55721 .......................15 M55760 .......................15 M55837 .......................15 M55900 .......................15 M55901 .......................15 M55902 .......................15 M55915 .......................15 M55916 .......................15 M55959 .......................15 M55980 .......................15 M55986 .......................19 M55987 .......................19 M55988 .......................13 M55989 .......................13 M55994 .......................15 M55995 .......................15 M56009 .......................15 M56072 .......................13 M56092 .......................13 M56093 .......................13 M56094 .......................13 M56095 .......................13 M56126 .......................23 M56128 .......................23 M56129 .......................23 M56165 .......................13 M56166 .......................13 M56167 .......................13 M56168 .......................13 M56210 .......................15 M56230 .......................15 M56256 .......................15 M56669 .......................21 M56670 .......................13 M56700 .......................22 M56726 .......................24 70 MOHAWK Mohawk P/N Page M56746 .......................13 M56753 .......................22 M56760 .......................21 M56773 .......................22 M56801 .......................23 M56809 .......................21 M56823 .......................21 M56832 .......................22 M56871 .......................26 M56876 .......................13 M56877 .......................13 M56878 .......................13 M56882 .......................13 M56889 .........................9 M56905 .........................9 M56912 .......................21 M56954 .......................13 M56985 .......................24 M57009 .......................21 M57040 .......................22 M57041 .......................26 M57042 .......................26 M57048 .......................13 M57071 .......................24 M57073 .......................24 M57074 .......................24 M57075 .......................24 M57076 .......................24 M57077 .......................24 M57098 .......................23 M57113 .......................13 M57116 .......................21 M57129 .......................13 M57193 .........................9 M57194 .........................9 M57195 .........................9 M57196 .........................9 M57197 .........................9 M57198 .........................9 M57199 .........................9 M57200 .........................9 M57201 .........................9 M57202 .........................9 M57203 .........................9 M57204 .........................9 M57205 .........................9 M57206 .........................9 M57207 .........................9 M57208 .........................9 M57209 .........................9 M57210 .........................9 M57211 .......................23 M57216 .......................24 M57269 .......................21 Mohawk P/N Page M57277 .......................21 M57322 .......................19 M57360 .......................19 M57361 .......................19 M57362 .......................19 M57363 .......................19 M57364 .......................19 M57365 .......................19 M57366 .......................19 M57367 .......................19 M57370 .......................19 M57371 .......................19 M57372 .......................19 M57373 .......................19 M57374 .......................19 M57375 .......................19 M57376 .......................19 M57377 .......................19 M57378 .......................19 M57404 .......................30 M57407 .......................30 M57408 .......................30 M57409 .......................30 M57410 .......................30 M57411 .......................30 M57413 .........................7 M57414 .........................7 M57415 .........................7 M57416 .........................7 M57417 .........................7 M57418 .........................7 M57419 .........................7 M57420 .........................7 M57421 .........................7 M57422 .........................7 M57507 .......................24 M57508 .......................24 M57509 .......................24 M57511 .......................24 M57512 .......................24 M57517 .......................24 M57518 .......................24 M57519 .......................24 M57520 .......................24 M57542 .......................24 M57543 .......................24 M57544 .......................24 M57545 .......................14 M57546 .......................14 M57547 .......................14 M57548 .......................14 M57550 .......................14 M57551 .......................14 M57552 .......................14 Mohawk P/N Page M57553 .......................14 M57554 .......................14 M57555 .......................14 M57556 .......................14 M57557 .......................14 M57561 .......................26 M57562 .......................26 M57564 .......................21 M57570 .......................24 M57620 .........................7 M57621 .........................7 M57622 .......................26 M57623 .......................26 M57626 .......................30 M57627 .......................30 M57628 .......................30 M57629 .......................30 M57630 .......................30 M57631 .......................30 M57634 .......................24 M57635 .......................24 M57636 .......................24 M57637 .......................24 M57638 .......................24 M57639 .......................24 M57640 .......................24 M57641 .......................24 M57642 .......................24 M57656 .......................26 M57662 .......................21 M57750 .........................7 M57761 .......................14 M57770 .......................24 M57850 .......................21 M57860 .........................7 M57861 .........................7 M57866 .........................7 M57867 .........................7 M57868 .........................7 M57869 .........................7 M57870 .........................7 M57887 .......................14 M57924 .......................14 M57936 .......................14 M57996 .......................23 M58007 .......................14 M58008 .......................14 M58009 .......................14 M58010 .......................14 M58103 .......................13 M58104 .......................14 M58116 .......................28 M58126 .......................24 M58127 .......................24 Mohawk P/N Page M58128 .......................24 M58129 .......................24 M58130 .......................24 M58131 .......................24 M58132 .......................24 M58133 .......................24 M58134 .......................24 M58135 .......................24 M58141 .......................22 M58142 .......................22 M58143 .......................21 M58144 .......................20 M58145 .......................20 M58155 .......................17 M58156 .......................17 M58157 .......................17 M58158 .......................17 M58159 .......................17 M58160 .......................17 M58161 .......................17 M58162 .......................17 M58163 .......................17 M58164 .......................17 M58175 .......................17 M58176 .......................17 M58177 .......................17 M58178 .......................17 M58179 .......................17 M58180 .......................17 M58181 .......................17 M58182 .......................17 M58183 .......................17 M58184 .......................17 M58185 .......................20 M58186 .......................20 M58187 .......................20 M58188 .......................20 M58189 .......................20 M58190 .......................20 M58191 .......................20 M58192 .......................20 M58193 .......................20 M58195 .......................20 M58196 .......................20 M58197 .......................20 M58198 .......................20 M58199 .......................20 M58200 .......................20 M58201 .......................20 M58202 .......................20 M58203 .......................20 M58204 .......................24 M58205 .......................24 M58208 .......................24 Locator Mohawk P/N Page M58209 .......................24 M58210 .......................24 M58211 .......................24 M58212 .......................24 M58213 .......................24 M58214 .......................24 M58215 .......................24 M58216 .......................24 M58217 .......................24 M58218 .......................24 M58219 .......................24 M58220 .......................24 M58221 .......................24 M58222 .......................24 M58226 .......................24 M58280 .......................11 M58281 .......................11 M58282 .......................11 M58283 .......................11 M58285 .......................11 M58286 .......................11 M58287 .......................11 M58288 .......................11 M58289 .......................11 M58290 .......................11 M58291 .......................11 M58292 .......................11 M58293 .......................11 M58294 .......................11 M58295 .......................11 M58296 .......................11 M58297 .......................11 M58298 .......................11 M58299 .......................11 M58300 .......................11 M58349 .......................23 M58405 .........................7 M58414 .........................9 M58452 .......................25 M58453 .......................25 M58454 .......................25 M58455 .......................25 M58456 .......................25 M58457 .......................25 M58460 .......................25 M58461 .......................25 M58462 .......................25 M58463 .......................28 M58509 .......................29 M58520 .......................22 M58521 .......................22 M58522 .......................22 M58527 .......................26 M58577 .......................28 M58620 .......................29 Mohawk P/N Page M58622 .......................29 M58629 .......................29 M58630 .......................29 M58650 .........................5 M58651 .........................5 M58652 .........................5 M58653 .........................5 M58646 .........................5 M58647 .........................5 M58648 .........................5 M58649 .........................5 M58762 .......................27 M58772 .......................27 M92000s ............see M9X M93000s ............see M9X M95830 .......................31 M95890 .......................50 M96436 .......................50 M96512 .......................31 M96551 .......................51 M96566 .......................51 M96567 .......................51 M96568 .......................51 M96569 .......................51 M96570 .......................51 M96571 .......................51 M96572 .......................51 M96573 .......................51 M96574 .......................51 M96575 .......................51 M96632 .......................31 M96633 .......................31 M96639 .......................51 M98177 .......................50 M9A000’s...........see M9X M9B000’s...........see M9X M9C000’s...........see M9X M9D000’s...........see M9X M9E000’s ...........see M9X M9W000’S..........see M9X M9X001 .......................50 M9X002 .......................50 M9X003 .......................50 M9X004 .......................50 M9X005 .......................38 M9X006 .......................38 M9X007 .......................38 M9X008 .......................38 M9X009 .......................38 M9X010 .......................38 M9X011 .......................38 M9X012 .......................38 M9X013 .......................39 M9X014 .......................39 M9X015 .......................39 Mohawk P/N Page M9X016 .......................39 M9X017 .......................39 M9X018 .......................39 M9X019 .......................39 M9X020 .......................39 M9X021 .......................40 M9X022 .......................40 M9X023 .......................40 M9X024 .......................40 M9X025 .......................40 M9X026 .......................40 M9X027 .......................40 M9X028 .......................40 M9X029 .......................41 M9X030 .......................41 M9X031 .......................41 M9X032 .......................41 M9X033 .......................41 M9X034 .......................41 M9X035 .......................41 M9X036 .......................41 M9X037 .......................34 M9X038 .......................34 M9X039 .......................34 M9X040 .......................34 M9X042 .......................34 M9X043 .......................35 M9X044 .......................35 M9X045 .......................35 M9X046 .......................35 M9X048 .......................35 M9X080 .......................50 M9X081 .......................50 M9X082 .......................39 M9X083 .......................38 M9X100 .......................36 M9X101 .......................36 M9X102 .......................36 M9X103 .......................36 M9X104 .......................36 M9X150 .......................47 M9X151 .......................47 M9X152 .......................47 M9X153 .......................47 M9X154 .......................47 M9X155 .......................47 M9X170 .......................47 M9X171 .......................47 M9X172 .......................47 M9X173 .......................47 M9X174 .......................47 M9X175 ...........................47 M9X202 .......................46 M9X204 .......................46 M9X205 .......................46 Mohawk P/N Page M9X206 .......................46 M9X207 .......................46 M9X209 .......................46 M9X211 .......................46 M9X215 .......................46 M9X240 .......................49 M9X241 .......................49 M9X242 .......................49 M9X243 .......................49 M9X244 .......................49 M9X245 .......................49 M9X246 .......................49 M9X247 .......................49 M9X248 .......................49 M9X381T .....................43 M9X382T .....................43 M9X384T .....................43 M9X386T .....................43 M9X389T .....................43 M9X391T .....................43 M9X393T .....................43 M9X398T .....................43 M9X400T .....................43 M9X500T .....................42 M9X502T .....................42 M9X505T .....................42 M9X507T .....................42 M9X509T .....................42 M9X510T .....................42 M9X511T .....................42 M9X513T .....................42 M9X520T .....................42 M9X601 .......................34 M9X602 .......................34 M9X604 .......................34 M9X606 .......................34 M9X609 .......................34 M9X611 .......................35 M9X612 .......................35 M9X614 .......................35 M9X616 .......................35 M9X619 .......................34 M9X620 .......................35 M9X621 .......................35 M9X622 .......................34 M9X623 .......................35 M9X630 .......................37 M9X631 .......................37 M9X632 .......................37 M9X633 .......................37 M9X634 .......................37 M9X640 .......................37 M9X641 .......................37 M9X642 .......................37 M9X643 .......................37 Mohawk P/N Page M9X644 .......................37 M9X700 .......................48 M9X701 .......................48 M9X702 .......................48 M9X703 .......................48 M9X704 .......................48 M9X705 .......................48 M9X720 .......................48 M9X721 .......................48 M9X722 .......................48 M9X723 .......................48 M9X724 .......................48 M9X725 .......................48 M9X740 .......................48 M9X741 .......................48 M9X742 .......................48 M9X743 .......................48 M9X744 .......................48 M9X745 .......................48 M9X810 .......................44 M9X811 .......................44 M9X812 .......................44 M9X813 .......................44 M9X814 .......................44 M9X815 .......................44 M9X816 .......................44 M9X817 .......................44 M9X890 .......................45 M9X891 .......................45 M9X892 .......................45 M9X893 .......................45 M9X894 .......................45 M9X895 .......................45 M9X896 .......................45 M9X897 .......................45 A0403634....................52 A0408829....................52 A0408835....................52 AX100029....................52 AX100947....................52 AX101075....................52 AX101077....................52 AX101100....................53 AX101101....................53 AX101791....................52 AX101792....................52 AX101793....................52 AX101794....................52 AX101981....................52 AX101982....................52 AX101983....................52 AX101984....................52 AX102062....................52 MOHAWK 71
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Create Date : 2007:05:22 09:34:41Z Creator Tool : QuarkXPress(tm) 6.5 Modify Date : 2007:09:28 10:50:29-04:00 Metadata Date : 2007:09:28 10:50:29-04:00 Producer : QuarkXPress(tm) 6.5 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (PANTONE 485 C).%%+ (PANTONE 258 C).%%+ (PANTONE Process Cyan C).%%+ (PANTONE 661 C).%%+ (PANTONE 569 C).%%+ (PANTONE 202 C).%%+ (PANTONE 165 C).%%+ (PANTONE 290 C).%%+ (PANTONE 102 C).%%+ (PANTONE 155 C).%%+ (PANTONE 167 C).%%+ (PANTONE 286 C).%%+ (PANTONE 355 C).%%+ (PANTONE Cool Gray 5 C).%%+ (Orange).%%+ (PANTONE 144 C).%%+ (PANTONE 297 C).%%+ (PANTONE 375 C).%%+ (Aqua).%%+ (PANTONE 444 C).%%+ (PANTONE Rubine Red C).%%+ (PANTONE 330 C).%%+ (PANTONE 326 C).%%+ (Purple).%%+ (PANTONE 300 C).%%+ (PANTONE 471 C).%%CMYKCustomColor: 0 .95 1 0 (PANTONE 485 C).%%+ .43 .76 0 0 (PANTONE 258 C).%%+ 1 0 0 0 (PANTONE Process Cyan C).%%+ 1 .69 0 .09 (PANTONE 661 C).%%+ .98 0 .57 .17 (PANTONE 569 C).%%+ 0 1 .61 .43 (PANTONE 202 C).%%+ 0 .59 .96 0 (PANTONE 165 C).%%+ .25 .02 0 0 (PANTONE 290 C).%%+ 0 0 .95 0 (PANTONE 102 C).%%+ 0 .12 .28 0 (PANTONE 155 C).%%+ 0 .6 1 .17 (PANTONE 167 C).%%+ 1 .66 0 .02 (PANTONE 286 C).%%+ .94 0 1 0 (PANTONE 355 C).%%+ 0 0 0 .29 (PANTONE Cool Gray 5 C).%%+ 0 .45 1 0 (Orange).%%+ 0 .48 1 0 (PANTONE 144 C).%%+ .49 .01 0 0 (PANTONE 297 C).%%+ .41 0 .78 0 (PANTONE 375 C).%%+ 1 0 .55 0 (Aqua).%%+ .15 0 .15 .42 (PANTONE 444 C).%%+ 0 1 .15 .04 (PANTONE Rubine Red C).%%+ 1 0 .48 .6 (PANTONE 330 C).%%+ .87 0 .38 0 (PANTONE 326 C).%%+ .85 1 0 0 (Purple).%%+ 1 .44 0 0 (PANTONE 300 C).%%+ 0 .59 1 .18 (PANTONE 471 C).%%EndComments Format : application/pdf Title : Mohawk Cat.Inside 2006 Document ID : uuid:96c1f833-968a-401d-82f7-5d2ab9a9d81f Instance ID : uuid:6d26be8a-e9d3-4ea0-b1e3-47e838e1f86d Page Count : 72 Creator : QuarkXPress(tm) 6.5EXIF Metadata provided by EXIF.tools