112170 Catalog
230819-Catalog 230819-Catalog 230819-Catalog 784572 Batch7 unilog cesco-content
2014-07-05
: Pdf 112170-Catalog 112170-Catalog 784572 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 48
Download | |
Open PDF In Browser | View PDF |
Instrument Rated Metering Equipment Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation sectors. Milbank combines more than 85 years of expertise in electrical engineering design and manufacturing with a commitment to develop and globally implement sustainable, integrated power solutions. Milbank’s portfolio includes electric metering systems, PowerGen™ wind and solar solutions, and portable power. A thirdgeneration, family-owned business, Milbank is headquartered in Kansas City, Mo. For more information, please visit milbankworks.com. METERING Milbank meter sockets have set the standard for quality since 1927. With a 99.97% quality performance, thousands of active products to meet your utility’s requirements and tens of millions of sockets installed across the globe, our products help keep energy at work. And with 22 stocking locations across the U.S., and our OneSERT program to help during emergency situations, our meter sockets are ready to go, wherever the job may be. COMMERCIAL & INDUSTRIAL When it comes to commercial and industrial products, Milbank has it covered! We offer a complete line of junction boxes, telephone cabinet covers, transformer cabinets, wireways, pushbutton enclosures, consoles and thermal management products. We specialize in custom-built enclosures and are more than happy to design a solution for your specific project. Our commercial meter pedestals are easy to install, fast, safe and secure, and completely customizable. POWERGEN Milbank’s standby and portable generators give you the peace of mind of living life uninterrupted during increasingly frequent power outages caused by severe weather, high demand and other situations. Our electric vehicle supply equipment, wind turbines and power management systems give you reliable and sustainable ways to reduce both your energy costs and your impact on the environment. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Table of Contents 3 TABLE OF CONTENTS CT Rated Sockets Plunger bypass features & benefits................................................................................................................................... 4 20 amp CT rated............................................................................................................................................................ 5–8 Prewired CT rated............................................................................................................................................................. 9 Multi-position CT rated.................................................................................................................................................... 10 Lever bypass CT rated............................................................................................................................................... 11–12 Demand side management.............................................................................................................................................. 13 Stainless steel CT rated................................................................................................................................................... 14 CT Cabinets CT cabinets feature & benefits........................................................................................................................................ 16 Transformer cabinets................................................................................................................................................. 18–20 Stud & lug type mounting racks...................................................................................................................................... 21 Transformer cabinets with factory-installed CT racks................................................................................................. 22–23 Metered transformer cabinet........................................................................................................................................... 24 Transockets Transockets features & benefits page............................................................................................................................. 26 Transockets................................................................................................................................................................ 27–30 Pedestals Instrument Rated Pedestal............................................................................................................................................... 31 Instrument Rated Commerical Pedestals......................................................................................................................... 32 Test Switches Test switches features & benefits.................................................................................................................................... 34 Test switches............................................................................................................................................................. 35–36 Test switch worksheet..................................................................................................................................................... 37 Miscellaneous Meter Forms.............................................................................................................................................................. Accessories................................................................................................................................................................ Reference Information............................................................................................................................................... Index.......................................................................................................................................................................... Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 38–39 40–41 42–43 44–45 CT Rated Sockets Plunger Bypass Feature 1 4 4 3 UC7237-RL 2 UC7545-RL Highlights and Features 1 These units are available in a powder coated galvanized G90 steel or aluminum 3R shell. Plunger Bypass: Once meter is removed from socket, plunger bypass disengages and CTs are shunted. Connectors: #14 – 4 mechanical connectors provided for ease of connecting CT wires. If ring terminal is desired, use U prefix rather than UC. 3 Terminals: Range of 5 to 13 terminal block assemblies available to meet most of your single and three phase application needs. 4 Ringless/Ring Type: Units available in both ringless or ring type styles. 2 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 5 CT Rated Sockets 20 AMP CT RATED SOCKETS 20 Amp | 5-13 Terminals 2 2 3 3 1 4 1 1290 1299 7233 7235 7237 1 1291 1300 7544 7545 7582 2 2 2 3 UC7237-RL UC7545-RL UC7582-XL 20 Amp | CT Rated Sockets | Ringless | Plunger Bypass Catalog Number Terminals Service Hub Dimensions Knockouts Meter Form Connectors CU D" W" H" 1 2 3 5 1 1 ⁄4 4 UC1290-XL 5 OH/UG C.P. 3S #14 - 10 3 ⁄16 8 14 2 1 ⁄2 1 ⁄4 1 UC1299-XL 6 OH/UG C.P. 4S #14 - 10 5 3 ⁄16 8 14 2 1 1 ⁄2 1 1 ⁄4 1 ⁄4 UC7233-XL 7 OH/UG C.P. 7, 14, 15 & 24S #14 - 10 35⁄16 8 14 2 11⁄2 11⁄4 1 ⁄4 UC7235-XL 8 OH/UG C.P. 5S #14 - 10 5 3 ⁄16 8 14 2 1 1 ⁄2 1 1 ⁄4 1 ⁄4 UC7237-XL 13 OH/UG C.P. 6, 8, 9S & (ALT) 10S #14 - 10 3 ⁄16 8 14 2 1 ⁄2 1 ⁄4 1 ⁄4 5 1 1 20 Amp | CT Rated Sockets | Ring Type Catalog Number Terminals Service Hub Meter Form Connectors CU Bypass Dimensions Knockouts D" W" H" 1 2 5 1 1 3 ⁄4 UC1291-RL 5 OH/UG H.O. 3S #14 - 4 MAX Plunger 3 ⁄16 8 14 1 ⁄2 1 ⁄4 1 UC1300-RL 6 OH/UG H.O. 4S #14 - 4 MAX Plunger 5 3 ⁄16 8 14 1 1 ⁄2 1 1 ⁄4 1 ⁄4 UC7544-RL 8 OH/UG H.O. 5S #14 - 4 MAX Plunger 35⁄16 8 14 11⁄2 11⁄4 1 ⁄4 UC7545-RL 13 OH/UG H.O. 6, 8, 9S & (ALT) 10S #14 - 4 MAX Plunger 5 3 ⁄16 8 14 1 1 ⁄2 1 1 ⁄4 1 ⁄4 UC7582-XL 13 OH/UG None 3 ⁄16 8 14 1 ⁄2 1 ⁄4 1 ⁄4 C.P. 6, 8, 9S & (ALT) 10S #14 - 10 5 1 Notes • Hubs: For proper hub selection, see the hub suffix chart on the accessories page. • Bypass: Plunger type bypass automatically closes when meter is removed. • Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “U” (i.e. UC7544-RL becomes U7544-RL). Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 1 6 20 AMP CT RATED SOCKETS CT Rated Sockets 20 Amp | 1-Piece Cover | w/ Test Switch Provision 1 1 1 1 1 7442 7444 7445 7478 2 UC7478-YL 20 Amp | 1-Piece Cover | CT Rated Socket with Test Switch Provision* | Ringless Catalog Number Terminals Service Hub Connectors CU Meter Form Dimensions Knockouts D" W" H" 1 1 2 UC7442-RL 5 OH/UG H.O. #14 - #4 Max 3S 4 ⁄8 12 20 1 ⁄4 1 UC7478-RL 6 OH/UG H.O. #14 - #4 Max 4S 41⁄8 12 20 11⁄4 1 UC7444-RL 8 OH/UG H.O. #14 - #4 Max 5S 1 4 ⁄8 12 20 1 1 ⁄4 1 UC7445-RL 13 OH/UG H.O. #14 - #4 Max 6, 8, 9 & (ALT) 10S 41⁄8 12 20 11⁄4 1 1 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 Notes • Hubs: For proper hub selection, see the hub suffix chart on the accessory page. • Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog. Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. • Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “U” (i.e. UC7445-XL becomes U7445-XL). • *Test Switch Cover: Units on this page are not designated for use with test switch covers without removing test switch bridge prior to installing test switch. • Test Switch Configurations: See page 34 for standard test switch configurations and page 35 for utility-specified test switches. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 7 CT Rated Sockets 20 AMP CT RATED SOCKETS 20 Amp | 2-Piece Cover | w/ Test Switch Provision 1 1 1 1 1 2 1 7446 7448 7449 7532 1 1 1 1 2 7450 7460 7461 7636 UC7449-RL 20 Amp | 2-Piece Cover | CT Rated Socket with Test Switch Provision* Ringless Ring Type Terminals Service Hub Catalog Number Catalog Number Connectors CU Meter Form Dimensions Knockouts D" W" H" 1 2 UC7446-RL UC7450-RL 5 OH/UG H.O. #14 - #4 Max 3S 4 ⁄8 12 20 1 ⁄4 UC7532-RL UC7636-RL 6 OH/UG H.O. #14 - #4 Max 4S 41⁄8 12 20 11⁄4 1 UC7448-RL UC7460-RL 8 OH/UG H.O. #14 - #4 Max 5S 4 ⁄8 12 20 1 1 ⁄4 1 UC7449-RL UC7461-RL 13 OH/UG H.O. #14 - #4 Max 6, 8, 9 & (ALT) 10S 41⁄8 12 20 11⁄4 1 1 1 1 ⁄4,1⁄2 1 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 Notes • Hubs: For proper hub selection, see the hub suffix chart on the accessory page. • Sealing Rings: Ring type units are supplied with one MR-2 snap-type sealing ring. • Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog. Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. • Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “U” (i.e. UC7449-XL becomes U7449-XL). • *Test Switch Cover: Units on this page are not designated for use with test switch covers. • Test Switch Configurations: See page 34 for standard test switch configurations and page 35 for utility-specified test switches. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 8 CT Rated Sockets 20 AMP CT RATED SOCKETS 20 Amp | Deeper 51⁄8" Shell | w/ Test Switch Provision 1 1 1 1 1 2 1 3423 3425 3426 3428 UC3423-XL 1 1 1 1 3433 3435 3436 3438 3434 1 UC3433-XL 20 Amp | 2-Piece Cover | CT Rated Socket with Test Switch Provision Ringless Ring Type Connectors Terminals Service Hub Catalog Number Catalog Number CU Meter Form Dimensions D" W" H" Knockouts 1 2 UC3425-XL UC3435-XL 5 OH/UG C.P. #14 - #2 Max 3S 5 ⁄8 12 20 1 ⁄4 1 UC3426-XL UC3436-XL 6 OH/UG C.P. #14 - #2 Max 4S 51⁄8 12 20 11⁄4 1 UC3428-XL UC3438-XL 8 OH/UG C.P. #14 - #2 Max 5S 5 ⁄8 12 20 1 1 ⁄4 1 UC3423-XL UC3433-XL 13 OH/UG C.P. #14 - #2 Max 6, 8, 9 & (ALT) 10S 51⁄8 12 20 11⁄4 1 — UC3434-XL 15 OH/UG C.P. #14 - #2 Max 20 11⁄4 1 39S or 76S 1 1 51⁄8 12 1 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 Notes • Hubs: For proper hub selection, see the hub suffix chart on the accessory page. • Sealing Rings: Ring-type units are supplied with one MR-4 screw type sealing ring. • Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog. Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. • Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “U” (i.e. UC3423-XL becomes U3423-XL). • Test Switch Cover: Units on this page can be used with clear lexan cover. See accessories page for ordering information. • Test Switch Configurations: See page 34 for standard test switch configurations and page 35 for utility-specified test switches. • EUSERC Approval: All ring-type items on this page are EUSERC compliant. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Prewired CT Rated Sockets Factory wired to utility specification UC7449-XL-871 For field-installable test switches, see page 34 for standard configurations. Test switches can also be factory installed without prewiring. Consult factory for details. Milbank’s CT Rated meter sockets are also available with factory prewiring and customspecified test switches. For factory prewiring and custom test switch configurations, see the worksheet on page 35 and consult factory for details. Available for both ring type and ringless applications. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 9 PREWIRED CT RATED SOCKETS 10 Multi-Position CT Rated Sockets TWO POSITION CT RATED SOCKETS 20 Amps | w/ Test Switch Provision UC3453-XL 1 1 SC6011-O-BL-21 1 2 1 3443 3453 3444 3458 3448 1 1 1 1 1 2 1 1 1 1 6010 2 1 1 1 1 1 2 1 1 1 1 2 1 1 1 1 6011 2 20 Amps | Multi-Position CT Rated Sockets | Ringless Catalog Number UL Connectors Positions Terminals Service Hub Listed CU Meter Form UC3458-XL Yes 2 8 OH/UG C.P. #14 - #4 Max UC3453-XL Yes 2 13 OH/UG C.P. #14 - #4 Max 6, 8, 9 & (ALT) 10S SC6010-O-BL-21 No 1 13 SC6011-O-BL-21 No 2 13 Dimensions D" W" H" Knockouts 1 2 5 25 ⁄16 20 1 ⁄4 1 5 251⁄16 20 11⁄4 1 UG Blank #14 - #4 Max 6, 8, 9 & (ALT) 10S 4 ⁄8 36 ⁄16 20 1 1 ⁄2 1 UG Blank #14 - #4 Max 6, 8, 9 & (ALT) 10S 41⁄8 4811⁄16 20 11⁄2 1 5S 1 1 7 1 ⁄4,1⁄2 ⁄4,1⁄2 ⁄2,3⁄4 ⁄2,3⁄4 20 Amps | Multi-Position CT Rated Sockets | Ring Type Catalog Number UL Positions Terminals Service Hub Listed Connectors CU Meter Form Dimensions D" Knockouts W" H" 1 2 UC3448-XL Yes 2 8 OH/UG C.P. #14 - #4 Max 5S 5 ⁄8 25 ⁄16 20 2 1 UC3443-XL Yes 2 13 OH/UG C.P. #14 - #4 Max 6, 8, 9 & (ALT) 10S 51⁄8 251⁄16 20 2 1 UC3444-XL Yes 2 15 OH/UG C.P. #14 - #4 Max 39S or 76S 51⁄8 251⁄16 20 2 1 1 1 ⁄4,1⁄2 ⁄4,1⁄2 ⁄4,1⁄2 Notes • Hubs: For proper hub selection, see the hub suffix chart on the accessory page. • Sealing Rings: Ring-type units are supplied with one MR-4 screw type sealing ring. • Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. • Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “U” (i.e. UC3453-XL becomes U3453-XL). • The SC6010 and SC6011 include a section for additional electronic components. Remote CT cabinet required. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 11 Lever Bypass CT Rated Sockets 80 AMP LEVER BYPASS CT RATED 80 Amps | Ringless | 600 VAC 4 5 2 1 2 3 4490 4492 4493 2 U4490-XL U4493-XL 80 Amps | Transformer Rated Sockets | Lever Bypass | Ringless Catalog Number Terminals Service Hub Connectors CU Bypass Dimensions Knockouts D" W" H" 1 2 7 3 U4490-XL 6 OH/UG C.P. #14 - #4 Max Lever 4 ⁄8 10 18 ⁄2 3 1 ⁄2 1 U4492-XL 8 OH/UG C.P. #14 - #4 Max Lever 7 4 ⁄8 10 18 ⁄2 3 1 1 ⁄2 1 U4493-XL 13 OH/UG C.P. #14 - #4 Max Lever 4 ⁄8 10 18 ⁄2 3 1 ⁄2 1 7 1 1 1 1 1 4 3 ⁄2, ⁄4 3 3 ⁄2, ⁄4 3 ⁄2, ⁄4 3 3 5 ⁄4 1 ⁄4 1 ⁄4 ⁄4 1 ⁄4 ⁄4 Notes • Hubs: For proper hub selection, see the hub suffix chart on the accessories page. • Bypass: Lever operates current bypass device and also supplies clamping action on current meter spades. • Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are preferred, change catalog prefix to “U” (i.e. UC4490-XL becomes U4490-XL). • Removable Handle: When removable handle is desired add suffix “-RH” to catalog number (i.e. U4493-XL becomes U4493-XL-RH). • Replacement Removable Handle: When a replacement removable handle (RH) is required order part #Z706850-SC. Replacement handle will only work with factory ordered RH units. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 12 Lever Bypass CT Rated 20 AMP LEVER BYPASS CT RATED 20 Amp | Ringless | w/ Test Switch Provision 1 1 1 1 1 2 4494 4496 4497 U4497-XL U4496-ZL-WC-41 20 Amp | Ringless | 1-Piece Cover | CT Rated Socket with Test Switch Provision Catalog Number Terminals Service Hub Connectors CU Bypass Dimensions Knockouts D" W" H" 1 7 2 U4494-XL 6 OH/UG C.P. #14 - #4 Max Lever 4 ⁄8 12 22 1 ⁄2 1 U4496-XL 8 OH/UG C.P. #14 - #4 Max Lever 47⁄8 12 22 11⁄2 1 ⁄4,1⁄2 U4497-XL 13 OH/UG C.P. #14 - #4 Max Lever 47⁄8 12 22 11⁄2 1 ⁄4,1⁄2 1 ⁄4,1⁄2 Notes • Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. • Connectors: Units are supplied with mechanical type connectors (#4 max). • Test Switch Cover: Units on this page can be used with clear lexan cover. See accessories page for ordering information. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 13 Demand Side Management DEMAND SIDE MANAGEMENT 200/20 Amps | 4 Terminals | Ringless 3 1 1 4 1 1 3 2 4811 3 U4811-O-21 Application The right position is used for sub-metering by the serving utility when a special electric rate is given to customers for devices that can shed load during high energy demand. Contact your local utility for more information. Features • Low voltage compartment in lower right corner • Left position is a 200 amp, 4 terminal heavy duty lever bypass interior • Right position is 20 amp rated with a fifth terminal in the 9 o’clock position and a plunger bypass • Right position is pre-wired to the terminal strip for easy installation 200/20 Amps | 4 Terminals | Two Positions | Off-Peak Metering Connectors / CU Catalog Number Service U4811-O-21 UG Left Side Right Side (Line & Load) #6-350 Terminal Strip Dimensions Bypass Lever/Plunger Knockouts D" W" H" 1 2 47⁄8 21 18 2 11⁄4 Notes • Fifth Terminal: For field installed fifth terminal on left (200 amp) side, order catalog number K3866. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 3 ⁄4 3 4 ⁄4,1⁄2 1 14 Stainless Steel CT Rated STAINLESS STEEL CT RATED 20 Amps | with Test Switch Provision 3423 3433 UCSS3433-O (shown as UCSS3433-O-141 pre-wired unit) 20 Amps | Ringless | CT Rated Socket with Test Switch Provision | Stainless Steel Catalog Number Terminals Service Hub Connectors CU Cover UCSS3423-O 13 OH/UG Blank #14 - #2 Max 2-Piece Dimensions D" W" H" 51⁄8 12 20 Knockouts None 20 Amps | Ring Type | CT Rated Socket with Test Switch Provision | Stainless Steel Catalog Number Terminals Service Hub Connectors CU Cover UCSS3433-O 13 OH/UG Blank #14 - #2 Max 2-Piece Dimensions D" 51⁄8 W" H" 12 20 Knockouts None Notes • For Conduit Opening Applications: All conduit openings have dimples provided to center location. Top conduit opening must have water-tight hub installed. • Other Stainless Steel Products: Most units available in stainless steel—contact Milbank for details. • EUSERC Approval: The UCSS3433-O is EUSERC compliant. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Notes Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 15 NOTES CT Cabinets Features & Benefits 1 5 4 3 2 6 U5990-O (Window-style CT— not included) Highlights and Features 1 Powder Coat Painted NEMA 3R Shell: As with all Milbank products, our enclosures are constructed of G90U galvenized steel and finished with attractive, light gray, baked powder coating. Our state-of-the-art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, non-fading finish. 2 Three-Point Latching Handle & Locking Mechanism: Padlocking handle with three-point latching system allows for easy locking and securing of the unit. 3 Hinged Double Doors: Hinged overlapping double doors enhance ease-of-access and are secured with three-point latching system. 4 Bar-Type CT Rack: Includes pre-placed studs to mount bar-type CTs. Withstand rating is 50K. 5 Lugs: Line, load and neutral rack lugs are single 600 kcmil or twin 250 kcmil. 6 Grounding Lug: Single position, 350 kcmil. Some units available in stainless steel—contact Milbank for details. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Notes Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 17 NOTES 18 Current Transformer Cabinets TRANSFORMER CABINETS Continuous Hinge | Padlock Provision Current Transformer Cabinets | Type 3R Dimensions Panel Size Catalog Number Gauge Steel W" H" D" W” H” Painted Steel Panel Catalog Number Wood Backboard Catalog Number 243210-LC3R-SP 14 24 32 10 21 29 A-24P32 A-24P32W 303610-LC3R-SP 14 30 36 10 27 33 A-36P30 A-36P30W 323610-LC3R-SP 14 32 36 10 29 33 A-32P36 A-32P36W 363612-LC3R-SP 14 36 36 12 33 33 A-36P36 A-36P36W 423616-CT3R 14 42 36 16 39 33 A-42P36 A-42P36W PT Cabinets Dimensions Catalog Number D" W" PT48L 8 8 PT48AL 8 12 36 2 ⁄2" - right side Aluminum PT48R 8 8 271⁄2 21⁄2" - left side Steel PT48AR 8 12 36 2 ⁄2" - left side Aluminum Notes Knockout H" 271⁄2 21⁄2" - right side 1 1 Material Steel PT48AR* S7860 • Features: Supplied with studs, continuous hinge and padlock provision. Steel panels and plywood backboard are optional. • LC3R-SP: Indicates a single door with two padlockable wind handles. • *PT48: PT48L and PT48AL has mounting emboss on the right side to be mounted on left side of CT cabinet. PT48R and PT48AR have mounting emboss on left side to be mounted on right side of CT cabinet. • Pole Mounting: For pole mounted CT rack applications, order catalog number S7860. • There are other sizes of outdoor transformer cabinets available, contact Milbank or refer to our enclosures catalog for details. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 19 Transformer Cabinets TRANSFORMER CABINETS CT and PT Cabinets Application • For use as a current transformer cabinet or panel enclosure. • For outdoor use to provide protection against rain, sleet and snow, or indoor use to protect against dripping water. Construction • Enclosure and cover manufactured from 16 or 14 gauge G90U galvanized steel. • The doors are overlapping with no center post. • Continuous door hinge with stainless steel hinge pins. • Three point pad-lockable handle. • Panel mounting studs provided for optional back panels. • Drip shield top and seam-free sides, front and back. 363612-CT3R Finish • ANSI 61 gray polyester powder coating over phosphatized G90U galvanized steel. Current Transformer Cabinets | Panel Enclosure Catalog Number Weight 303610-CT3R Dimensions Steel Panel Catalog # Wood Panel Catalog # W" H" D" 99 30 36 10 A-36P30 A-36P30W 363010-CT3R 99 36 30 10 A-36P30 A-36P30W 363016-CT3R 121.5 36 30 16 A-36P30 A-36P30W 363610-CT3R 113 36 36 10 A-36P36 A-36P36W 363612-CT3R 118 36 36 12 A-36P36 A-36P36W 363616-CT3R 139 36 36 16 A-36P36 A-36P36W 443010-CT3R 116 44 30 10 A-30P44 A-30P44W 483612-CT3R 147 48 36 12 A-48P36 A-48P36W 483616-CT3R 163 48 36 16 A-48P36 A-48P36W 484812-CT3R 210 48 48 12 A-48P48 A-48P48W 606013-CT3R 274 60 60 13 A-60P60 A-60P60W Notes • Wall or Pole Mount: For wall or pole mount CT rack order S7860. This unit accomodates 3 donut style CTs. The removable cover makes wiring much easier. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 20 TRANSFORMER CABINETS Current Transformer Cabinets Compatible with Field Installable Racks Screw Cover Current Transformer Cabinets * Catalog Number * * * * * * * * * * CT24329-SC CT242411-SC CT243011-SC CT243611-SC CT244811-SC CT303011-SC CT303611-SC CT303614-SC CT363611-SC CT364211-SC CT364811-SC CT364814-SC CT424211-SC CT484811-SC Dimensions W" H" D" C, M 24 32 9 A4, C, M, Q 24 24 11 A4, C, M, Q 24 30 11 A4, C, J, M, Q 24 36 11 A, C, D, J, M, Q 24 48 11 A4, B4, C, E, L, M, Q, R 30 30 11 A4, B4, C, E, J, K, L, M, Q, R 30 36 11 A4, B4, C, E, J, K, L, M, Q, R 30 36 14 A4, B4, C, E, J, K, L, M, Q, R 36 36 11 A4, B4, C, E, J, K, L, M, Q, R 36 42 11 A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R 36 48 11 A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R 36 48 14 A4, B4, C, E, J, K, L, M, Q, R 42 42 11 A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R 48 48 11 Compatible CT Racks (see next page for matching code) Front Cover 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece 2 Pieces 2 Pieces 2 Pieces 2 Pieces 2 Pieces CT24329-SC Hinge Cover Current Transformer Cabinets * Catalog Number * * * * * * * * CT203611-HC CT243011-HC CT243611-HC CT244811-HC CT303611-HC CT304811-HC CT363611-HC CT364811-HC CT484811-HC CT364814-HC CT484814-HC Compatible CT Racks (see next page for matching code) C A4, C, M, Q C, M A, C, D, J, M, P, Q A4, B4, C, E, J, K, L, M, Q, R A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R A4, B4, C, E, J, K, L, M, Q, R A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R Dimensions Front W" H" D" Cover 20 36 11 1 Piece 24 30 11 1 Piece 24 36 11 1 Piece 24 48 11 1 Piece 30 36 11 1 Piece 30 48 11 1 Piece 36 36 11 1 Piece 36 48 11 1 Piece 48 48 11 2 Pieces 36 48 14 2 Pieces 48 48 14 2 Pieces CT203611-HC Notes • EUSERC Approval: Units denoted with an asterisk (*) are EUSERC compliant. • Enclosure: These units are rated Type 3R, powder coat painted and constructed of galvanized steel. • Mounting Rack: Select CT mounting rack from the next page. • Mounting: 1⁄4-20 welded studs spaced to accept mounting racks. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 21 CT Cabinet Mounting Racks CT CABINET MOUNTING RACKS Stud & Lug Types K4797 K4798 K4729 K5932 K4793 K5933 K5930 Screw Cover Current Transformer Cabinets * Code Catalog Number SCCR Rating Amps Volts Type of Service * A4 K4797 50K 400 600 1Ø3W 1 * A K4797 50K 800 600 1Ø3W 1 * B4 K4798 50K 400 600 3Ø4W 1 * B K4798 50K 800 600 3Ø4W 1 * C K4793 10K 201–400 600 1Ø3W 1 * D K4795 10K 401–800 600 1Ø3W 1 * E K4794 10K 201–400 600 3Ø4W 1 * F K4796 10K 401–800 600 3Ø4W 1 * G K4729 50K 800 600 1Ø3W (3) #4-600 or (6) #1-250 * H K4722 50K 800 600 3Ø4W (3) #4-600 or (6) #1-250 * J K4903 50K 400 600 1Ø3W (1) #4-600 or (2) #1-250 * K K4904 50K 400 600 3Ø4W (1) #4-600 or (2) #1-250 L K5747 50K 800 600 3Ø4W Termination Type ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers M K5752 50K 800 600 1Ø3W Line: 1⁄2"-13 studs on 13⁄4" centers Load: (3) #4-600 or (6) #1-250 Line: 1⁄2"-13 studs on 13⁄4" centers Load: (3) #4-600 or (6) #1-250 N K5930 50K 800 600 3Ø4W (3) #4-600 or (6) #1-250 P K5931 50K 400 600 1Ø3W or 3Ø3W Q K5932 50K 400 600 1Ø3W or 3Ø3W 1 R K5933 50K 400 600 3Ø4W 1 (1) #4-600 or (2) #1-250 ⁄2"-13 studs on 13⁄4" centers ⁄2"-13 studs on 13⁄4" centers Notes • EUSERC Approval: Units marked with an asterisk are EUSERC compliant. • CT racks on this page are for use with bar type CTs. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com K4722 K5931 22 Current Transformer Cabinets TRANSFORMER CABINETS with Factory Installed CT Racks | 600 VAC Connector detail S1855-O Current Transformer Cabinets | Non-UL Approved Dimensions Catalog Number Amps Hub Gauge Steel Connectors CU/AL D" W" H" S1855-O 400–800 Blank 12 (3) 3/0-750 kcmil per phase 12 36 36 S1856-O 800–1200 Blank 12 (5) 3/0-750 kcmil per phase 12 48 48 Notes • Features: These enclosures have three-point locking handles, liftoff hinges with stainless steel pins and two doors. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 23 Current Transformer Cabinets 400 & 800 AMP TRANSFORMER CABINETS 400 & 800 Amps U4468-XT U5990-O Current Transformer Cabinets | 3Ø Catalog Number U4468-XT U4468-XT-K4469 U5990-O Ampacity Wiring Chart Amps Wire Qty. Per Phase 400 400 800 800 1 2 2 4 800 3 Aluminum Conductor Copper Conductor Hub — 600 kcmil (2) C.P. 250 kcmil 3/0 — 600 kcmil (2) C.P. 250 kcmil 3/0 600 kcmil 600 kcmil Blank or 2-250 or 2-250 Dimensions D" W" H" 10 24 45 10 24 45 10 36 36 Notes • Hubs: U4468 is supplied with two closing plates as standard. To order hubs, refer to the accessories section. • Studs: The U4468 is supplied with 1⁄2"-13 twin studs with hex nuts with Belleville washers to mount bar-type transformers. • 800 Amp Conversion Kit: To convert U4468 from 400 amps to 800 amps, order catalog number K4469. • Padlock: The U4468 is provided with a padlockable 2-point latch. The U5990 is provided with a padlockable handle with 3-point latching mechanism. • Withstand Rating: 50K SCCR available when conductors are lashed per instructions on label. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 24 Metered Transformer Cabinets METERED TRANSFORMER CABINETS Screw Cover | Ring Type 1 1 2 1 3320 3342 3322 3555 3340 3565 S3565-O Metered Transformer Cabinets | Ring Type Catalog Number Terminals Service Hub Dimensions Knockouts Compatible CT Racks (see pg. 21 for matching code) Type of Service D" W" H" 1 2 U3320-R 6 OH H.O. A, C, D, J, L, M 1Ø3W 11 24 42 4 1 U3322-R 13 OH H.O. B, E, F, G, H, L, M 3Ø4W Y or Δ 11 36 42 4 1 U3555-R 15 OH H.O. B, E, F, G, H, L, M 3Ø4W Y or Δ 11 36 42 4 1 U3340-O 6 UG Blank A, C, D, J, L, M 1Ø3W 11 24 52 4 1 U3342-O 13 UG Blank B, E, F, G, H, L, M 3Ø4W Y or Δ 11 36 52 4 1 U3565-O 15 UG Blank B, E, F, G, H, L, M 3Ø4W Y or Δ 11 36 52 4 1 Notes • Meter Socket: 20 amp current transformer meter socket built in. • Enclosure: NEMA Type 3R with screw cover. • Current Transformer Mounting: 1⁄4–20 welded studs. • Hubs: For proper hub selection, see hub suffix chart in the accessories section. • Sealing Rings: Supplied with MR-4 screw type sealing ring. • Lugs: For mounting rack information, refer to page 21. • Test Switches: These units include test switch provision to mount above or below CT rack. Will accept 7 or 10 pole test switches. • EUSERC Approval: All units on this page are EUSERC compliant. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Notes Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 25 NOTES Transockets Features & Benefits 4 6 1 2 3 5 AP6014-O-400-NKO-21 Highlights and Features Transocket Overhead/Underground Capabilities: From the factory, the rack is oriented for underground applications but can be rotated 180° for overhead applications. The neutral lugs can be mounted on the side for overhead applications. The VT pack mounting bridge moves from the top to the right side for overhead applications. 1 NEMA 3R Aluminum Shell: The alumnium shell reduces the overall weight of the unit compared to a steel shell. Shell is powder coated. 2 Meter Socket & Test Switch on Swinging Door: Unit includes a 13-terminal CT-rated block. An 8-terminal block option is also available. Includes a 10-pole test switch. A 7-pole test switch option is also available. Factory pre-wired to conform to individual utility specifications. 3 Utility-Specific Wiring Harness: Wiring harness is color configured and wired per the utility specifications. 4 VT Pack Mounting Bridge: VT pack mounting bridge allows for installation of VT packs. 5 Wall Mount Bracket: Provides an easier means of installation for one installer, who can premount the bracket and then hang the unit onto the wall bracket. 6 Stainless Steel Liftoff Handles: The durable, rust-resistant hinged handles lay flat against the front. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 27 Transockets 400–600 AMP TRANSOCKETS 400–600 Amps | Ringless | 600 VAC S9573-X S2674-XT 2 S1890-XT 2 3 1 1 1 1 2 2 9573 3 1 2 2 3 1 3 1 2674 2690 3831 2 1 1 2 1 2 1 1890 1891 3912 400 Amps | Transockets | Bar Type CTs Only | Ringless | 600 VAC Dimensions Knockouts Catalog Number Terminals Meter Form Hub CTs Qty. and Ratio Termination Type D" W" H" 1 S9573-X 6 4S C.P. (2) 200/5 Lay-in lugs 53⁄4 191⁄2 27 31⁄2 S3831-XT 6 4S (2) C.P. (2) 200/5 Mechanical lugs 111⁄4 18 30 S2690-XT 8 5S (2) C.P. (2) 200/5 Mechanical lugs 11 ⁄4 18 S2674-XT 13 8S (2) C.P. (3) 200/5 Mechanical lugs 111⁄4 18 1 2 3 ⁄4,1⁄2 — 4 31⁄2 1 30 4 1 3 ⁄2 1 30 4 31⁄2 1 1 600 Amps | Transockets | With PTs and Donut Type CTs | Ringless | 600 VAC Catalog Number Terminals Meter Form Hub PTs Qty. CTs Qty. and Ratio and Ratio S1891-XT 8 5S (2) C.P. (2) 4:1 (2) 200/5 S3912-XT-21 13 8S (2) C.P. (2) 4:1 (2) 200/5 S1890-XT 14 5S (2) C.P. (2) 4:1 (2) 200/5 Termination Type Lugs mounted directly to current transformer Lugs mounted directly to current transformer Lugs mounted directly to current transformer Dimensions Knockouts D" W" H" 1 2 1 9 ⁄2 18 24 2 ⁄2 1 11 1 9 ⁄2 18 24 1 2 ⁄2 1 11 9 ⁄2 18 24 2 ⁄2 1 11 1 1 Notes • Hubs: To order hubs as extra, refer to the hub suffix chart in the accessories section. • Prewiring: Units supplied prewired with test switch and transformers in place. Contact factory if prewiring is desired. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 3 1 ⁄16 ⁄16 ⁄16 28 Transockets TRANSOCKETS Compatible with CTs, PTs, or VT Packs 1 1 1 1 2777 2811 S2777-4X (shown factory prewired) A6014-O-400-NKO (shown factory prewired) 400–1000 Amps | 8 & 13 Terminals | Ringless | Transocket Catalog Number Terminals Service Phase Test Switch Hub VT Pack CTs Qty. Provision & Ratio Dimensions D" W" H" Knockouts A6015-O-400-NKO 8 OH/UG 1Ø or 3Ø3W 7-pole Blank Yes (2) 400/5 121⁄16 36 37 None A6014-O-400-NKO 13 OH/UG Yes (3) 400/5 12 ⁄16 36 37 None 3Ø4W 10-pole Blank 1 Notes • Shell: Shell is unpainted aluminum and 3R rated. • Prewiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio. • VT Pack Provision: VT pack bridge included; VT pack not included. • Removable/Rotatable CT Rack: These units include a CT rack which can be rotated 180 degrees for both overhead or underground applications. • Wall Mount Bracket: Bracket included for ease of hanging and installation. • Lugs: Lugs are included with these units. 1600 Amps | 14 Terminals | Ringless | 3Ø4W | Transocket Catalog Number Terminals Service Test Switch Hub PTs Quantity CTs Quantity & Ratio & Ratio Dimensions Knockouts D" W" H" 1 S2777-4X 14 OH/UG 10-pole (4) C.P. (2) 2.5:1 (3) 400/5 14 30 42 1 S2811-4X 14 OH/UG 10-pole (4) C.P. None (3) 400/5 14 30 42 1 ⁄2 ⁄2 Notes • Hubs: Units supplied with 4 closing plates as standard. To order hubs as extra, refer to the accessories page. • Pre-wiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio, and PTs if applicable. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 29 Transockets 400 AMP TRANSOCKETS 400 Amps | 600 VAC 1 1 1 1 1 1 2 1 2 2 2161 2228 2229 5944 U2161-XT U5944-XT (shown factory prewired) 400 Amps | 6–13 Terminals | Ringless | Transockets Catalog Number Terminals Service Front Cover Dimensions Knockouts Phase Test Switch Hub D" W" H" 1 2 1Ø Provision (2) C.P. 12 24 34 4 1 U2228-XT 6 OH/UG Hinged U2229-XT 8 OH/UG Hinged 1Ø or 3Ø3W Provision (2) C.P. 12 24 34 4 1 U2161-XT 13 OH/UG Hinged 3Ø4W Provision (2) C.P. 12 24 34 4 1 U5944-XT 13 OH/UG 3Ø4W Provision (2) C.P. 12 24 34 4 1 Lift-off Notes • Hubs: Units are supplied with two closing plates as standard. To order hubs as extra, refer to the accessories page. • Shell: Shell is powder-coat painted G90 galvanized steel and 3R rated. • Pre-wiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio. There is no provision for PTs in this unit. • Studs: 1⁄2"-13 twin studs are supplied to mount bar type transformers. Hex nuts with Belleville washers are also supplied. • Lugs: Lugs are included with these units. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 30 Transockets 200/400/800 AMP TRANSOCKETS 200/400/800 Amps | 600 VAC 3 4163 4166 2 1 1 1 3 1 2 1 1 1 4154 1 3 U4163-XT-11-LI 2 2 1 1 U4163-XT-11-LI 4554 1 200/400/800 Amps | 6 & 13 Terminals | Transockets | Ringless Catalog Number Terminals Service Amps Hub Connectors Line Load Phase Dimensions Knockouts D" W" H" 1 2 U4554-X-Z21-LI 6 OH/UG 200/400 C.P. #4-600 #4-600 1Ø 10 21 41 4 11⁄4 3 U4166-XT-Z21-LI 6 OH/UG 400/800 C.P. #4-600 #4-600 1Ø 10 26 51 4 1 1 ⁄4 3 U4523-X-Z11-LI 13 OH/UG 200/400 C.P. #4-600 #4-600 3Ø 10 21 41 4 1 1 ⁄4 3 U4163-XT-11-LI 13 OH/UG 400/800 C.P. #4-600 #4-600 3Ø 10 26 51 4 1 ⁄4 3 1 3* ⁄8 ⁄8 ⁄8 ⁄8 Notes • *Knockout #3: This is a 3⁄8" hole with plastic plug, not a concentric knockout. • Lugs: Lugs are provided and are rated up to single 600 kcmil - #4 AWG. • Short Circuit Current Withstand Rating: These units have a 50K short circuit current withstand rating. • Units furnished with 1/2"-13 studs, washers and hex nuts and bolt with conical washer for CT mounting. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 31 Instrument Rated Pedestal 20 Amps | 13 Terminals | With Test Switch Provision 1 1 S4084-O Ringless | Instrument Rated Pedestal | With Test Switch Provision Catalog Number Terminals Hub S4084-O 13 Blank Meter Form Connectors Bypass CU 6, 8, 9 & (ALT) 10S #14 - #4 Max None Dimensions Knockouts D" W" H" 1 41⁄8 12 58 11⁄4 Notes • Contact factory for details. • Also available in 6 & 8 terminals. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com INSTRUMENT RATED PEDESTAL 32 INSTRUMENT RATED PEDESTAL Instrument Rated Commercial Pedestals Attractive | Easy to Install | Secure | Cost-effective Milbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Standard Features • Type 3R rainproof, vandal-resistant cabinet of powder-coated steel (aluminum or stainless steel also available) • UL-listed as enclosed industrial control equipment (UL508) • Isolated lockable & sealable utility metering and lug landing sections • Lockable customer section for distribution and control equipment with internal deadfront • Print pocket inside customer section door contains wiring schematics and installation instructions • All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Notes Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 33 NOTES Test Switches Features & Benefits 1 5 6 3 2 4 Highlights and Features 1 Handle Color Options: Standard colors are black for current and red for potential. Many non-standard colors are available—contact Milbank for details. Handle material is polypropylene. 2 45 Degree Stops: 90 degree bends on 45 degree stops are standard. 180-degree bends are available where additional strength is required. 3 Test Switch Barriers: Test switch barriers are made of polycarbonate as standard. 4 Test Switch Covers: Polycarbonate (clear or black). Test switch cover is clear when factory-installed unless otherwise specified. 5 Test Switch Base: Test switch bases are red as standard and made of glass polyester. 6 Arboron Test Switch Base & Barriers Option: Base and barriers are available in Arboron, a thicker and more rigid material that provides extra strength. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 35 Test Switches TEST SWITCHES Details & Test Switch Covers Switch Blades Two dimples coined into one side of the switch blade ensure positive contact in corrosive, sooty environments—even after years of inactivity. Test Switch Covers Standard test switch covers are made from impact resistant clear thermal plastic which has excellent tracking and moisture resistant properties. If covers are required, add suffix -WC (with cover) to the catalog number or order separately catalog number K3388. Black flush mount covers are also available. Order catalog number K3388-BLK-FL. 10 pole base only. Test Switch Base The base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track resistant, flame retardant and has low water absorption qualities. Bases are available in 7 pole and 10 pole sizes. Switch Jaws The switch blade jaw clips are constructed from spring grade copper alloy. The material and design ensure excellent contact which prevents overheating. Polarity Barrier For maximum protection potential circuits are supplied with permanently mounted barriers made from high tensile strength polycarbonate. Current Carrying Parts Highly conductive copper and copper alloy materials are used on all current carrying parts. This ensures conductivity and deters corrosion. Spring grades are used where appropriate. Plating is available if required. Contact general offices to special order. Nickel Plating Option Corrosion-resistant test switches with nickel plating are available as an option. Standard Cover Flush Mount Cover (Black) Socket shells must be 51⁄8" deep -ORmust not have test switch bridge mounted on back in order to support a cover. Factory Installed: For cover installed add the suffix -WC or -WCFL to the catalog number of desired test switch. Field Installed: For field installed cover order kit number K3388 or K3388-BLK-FL. The Milbank test switch is designed to meet the critical requirements of the electric utility industry. Not only do they meet EEI, ANSI C12.9, and UL standards but they combine several special features giving the Milbank test switch increased safety, durability and reliability. One such feature is our unique switch blade contact points which cut through residue that builds up after years of service. Another distinction is our polarity barrier which is designed to be flexible as well as offer exceptional insulating qualities. Our test switches are constructed from the latest materials available using modern fabricating and assembly methods. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 36 Test Switches TEST SWITCHES 4, 7 & 10 Pole 3 1/2" 7 1/2" 3 1/2" 9 1/2" Key Catalog Number 4-Pole P Potential Switch TS04-0101 X P Pn X C+ C X C+ Line side current switch with short circuit assembly TS04-0104 X C+ C X P Pn X C Load side current switch with test jack assembly N Neutral bar (no switch) Pn Neutral Potential Switch X Unused Position on base C C+ C Catalog Number 7-Pole TS07-0105 P P Pn C+ Insulating barrier, isolates both sides of switch Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C+ line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussing is required, different catalog numbers will apply. Catalog Number 7-Pole on a 10-Pole Base TS07-0049 P X P X Pn X C+ C C C+ TS07-0106 X P C+ C P C+ C Pn X X Catalog Number 10-Pole TS10-0109 P P P Pn C+ C C+ C C+ C TS10-0110 P C+ C P C+ C P C+ C Pn TS10-0111 P P P Pn C C+ C C+ C C+ TS10-0112 C+ C C+ C C+ C P P P Pn TS10-0016 P P P Pn C C+ C C+ C C+ Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 37 Test Switch Worksheet TEST SWITCH WORKSHEET Electronic version available at milbankworks.com Customer Name:_________________________________________________________________ Address:________________________________________________________________________ ________________________________________________________________________________ Phone / Fax #: __________________________________________________________________ TEST SWITCH BASE Handle Color Key BK Black P Purple Y Yellow GN The base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track-resistant, flame-retardant and has low water absorption qualities. Bases are available in two standard sizes following NEMA mounting classifications. Green R Red BL Blue W White BKS Black Stripe BR Brown GR Grey O Orange WS White Stripe Pole Position Chart 1 2 3 4 5 6 7 8 9 10 Special Features Feature 1 2 3 4 5 6 7 8 9 10 45° Angle Stops Ganged Handles (C) Bussing Colored Handles Engineering Information: _________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Key P Potential Switch C+ Line side current switch with short circuit assembly C Load side current switch with test jack assembly N Neutral bar (no switch) Pn Neutral Potential Switch X Unused Position on base Insulating barrier (one side) Insulating barrier (two sides) Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C+ line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. Number of Poles q 7 q 10 q q Other ____ 4 Test Switch Cover (only available for 10-pole bases) q Yes | Clear ___ Black ___ No q Base Size q 10-Pole q 7-Pole Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 38 Watthour Meter Forms WATTHOUR METER FORMS Standard Forms | Transformer Rated or Self-Contained SC 2 and 3-WIRE FORMS 1S & 2S SC 2 and 3-WIRE FORMS 1S & 2S with BYPASS TR 2-WIRE FORM 3S 5th Term. 9 o'clock TR 2-WIRE FORM 3S with BYPASS TR SC SC SC 2-WIRE FORM 3S with BYPASS 2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 9 o'clock 2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 9 o'clock 2 ELEMENT 3-WIRE NETWORK FORM 12S 5th TERM. 6 o'clock TR TR SC 3-WIRE FORM 4S 3-WIRE FORM 4S WITH BYPASS TR 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 5S TR 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 5S with BYPASS 2 or 3 ELEMENT 3∅4W Y or ∆ Y FORM 14S ∆ FORM 15S SC 2 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 13S SC 2 or 3 ELEMENT 3∅4W Y or ∆ FORMS 14S & 15S with BYPASS SC 2 or 3 ELEMENT 2∅3W, 2∅4W, 3∅3W FORM 13S with BYPASS TR 2-WIRE FORM 3S 5th Term.6 o'clock SC 2 ELEMENT 3-WIRE NETWORK FORM 12S with BYPASS 5th Term. 6 o'clock TR 2 ELEMENT 3∅4W Y or ∆ Y FORM 7S ∆ FORM 24S with BYPASS TR 2 or 3 ELEMENT 3∅4W Y or ∆ Y FORM 9S ∆ FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR 2 or 3 ELEMENT 3∅4W Y or ∆ FORMS 8S & 9S with BYPASS TR TR 2 ELEMENT 3∅4W Y FORM 6S 2 ELEMENT 3∅4W Y FORM 6S with BYPASS Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 39 Meter Forms METER FORMS Reference Information DIAGRAM A 1∅2W with 1 P.T. & 1 C.T. Single Stator Meter(2W1∅) - Form 3S 5T Socket, Test Switch #TS04-0101 DIAGRAM B 1∅3W with 1 C.T. Single Stator Meter (2W1∅) - Form 3S 5T Socket, Test Switch #TS04-0101 DIAGRAM B DIAGRAM A DIAGRAM D 1∅3W or 3W Network with 2 C.T.’s 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS07-0105 DIAGRAM C DIAGRAM D (ALT.LOC.) (ALT.LOC.) + C1 P1 PN DIAGRAM C 1∅3W with 2 C.T.’s Single Stator Meter (3W1∅) - Form 4S 6T Socket, Test Switch #TS07-0105 P1 PN C1 + C1 C1 + C1 P1 P2 + C2 + C2 C2 + C1 P1 P2 PN + C2 C2 C1 + P.T. + + I LINE N + LOAD C.T. I + LINE 2 N C.T. + DIAGRAM E 3∅3W “∆” with 2 P.T.’s & 2 C.T.’s 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS07-0105 DIAGRAM F 3∅3W “∆” with 2 C.T.’s 2 Stator Meter - Form 5S 8T Socket, Test Switch #TS07-0105 DIAGRAM E P1 P3 LINE (BONDED) (BONDED) P 2 C+ 1 P 2 C+ 1 P1 P3 C.T. C.T. + LOAD + DIAGRAM G LINE P1 P 3 P N C+ + PT C+ C + + + C.T. + LOAD + C.T. C.T. + + C C P3 PN PT + C C P1 P2 P3 PN + C C PT C.T. C.T. + + C.T. (BONDED) + + LOAD C.T. C C+ C C+ + + C.T. + + LOAD C.T. C+ C C+ C 1 2 LINE 3 N(BONDED) + + + C.T. + + C.T. + + Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. C+ C PT PT + + 1 2 LINE 3 N(BONDED) + + C.T. + + C.T. + LOAD + C.T. Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com C + PT DIAGRAM J + + + + + + + C+ DIAGRAM J + 1 2 LINE 3 N(BONDED) 1 2 LINE 3 N LOAD + 3∅4W “Y” with 3 P.T.’s & 3 C.T.’s 3 Stator Meter - Form 9S 13T Socket, Test Switch #TS10-0109 DIAGRAM I P1 P2 P3 PN LOAD + C.T. DIAGRAM I 3∅4W “Y” or “∆” with 3 C.T.’s “Y” 3 Stator Meter - Form 9S “∆” 2 Stator Meter - Form 8S 13T Socket, Test Switch #TS10-0109 + + 1 LINE 2 3 + C.T. DIAGRAM H P1 + 1 LINE 2 3 C.T. 3∅4W “Y” with 2 P.T.’s & 3 C.T.’s 2 1⁄2 Stator Meter - Form 6S 13T Socket, Test Switch #TS10-0109 + PT + DIAGRAM H C+ C C + I N(BONDED) 2 DIAGRAM G + C3 C3 C1 + 3∅4W “Y” with 3 C.T.’s 2 1⁄2 Stator Meter - Form 6S 13T Socket, Test Switch #TS10-0109 DIAGRAM F + C3 C3 C1 + I N(BONDED) 2 LOAD LOAD C.T. 40 Accessories ACCESSORIES Hubs and Closing Plates -RL Small hub opening -WL A7514 -YL A7515 1 ⁄4" hub 1" hub -ZL A7516 -DL 1 ⁄2" hub 1 A7517 2" hub 1 -EL A7518 2 ⁄2" hub 1 -XL A7551 Small closing plate -R Large hub opening -F A8110 3" hub -G A8111 3 ⁄2" hub 1 -H A8112 4" hub -X A9064 Large closing plate -RRL S8324 Large hub opening adapted to small hub oepning Notes • Suffix: Add to catalog number for factory installation of hub. • Packaging: Individually packed units for field installation. • Abbreviations: H.O. (hub opening), C.P. (closing plate). Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 41 Accessories Closing Covers, Sealing Rings and Touch-Up Paint Sealing Rings Closing Covers Meter Closing Plate (Ring Type / Ringless) Metal Closing Plate (For Ringless Sockets) 6003 - Grey Plastic CP-21 MR-2 - Snap Action MR2-SS - Stainless Steel MR-4 - Screw Type (Stainless Steel) 6116 - Clear Plastic Touch-Up Paint A-GP - Light Grey Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com ACCESORIES 42 Energization of Electrical Equipment ENERGIZATION OF ELECTRICAL EQUIPMENT Important Information for Installers Important Note In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. Before Energizing A. Give equipment a thorough visual examination to determine that: 1) No shipping or installation damage exists. 2) Proper clearances have been maintained. 3) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: 1) Verify tightness of all bolted connections (see table below). 2) Manually operate all circuit breakers, switches, relays, etc. 3) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the “off” position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in case of accidental energization. When Energizing A. Use caution and follow established safety procedures: 1) Wear safety apparel. 2) Use safety equipment. 3) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. After Energizing A. Secure the installation: 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices. 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices. 3) Attach/post information to advise others of potential hazards associated with the installation. Recommended Torque for General Applications* Joint Description Nominal Size Screw Nut Head Type Torque (Inch Lbs.) 20-25 inch lbs. 10 Brass Brass Nut or Extruded Hole All 10 Steel Copper or Aluminum Busbar ≤ 1/8" All 25-30 inch lbs. 10 Steel Steel Nut or Extruded Hole; CU or AL Busbar > 1/8" All 30-35 inch lbs. 12 Steel Aluminum Extruded Hole All 30-35 inch lbs. 12 Steel Steel Nut or Extruded Hole All 40-50 inch lbs. 1/4 Steel Aluminum Extruded Hole All 40-50 inch lbs. 1/4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All 50-60 inch lbs. 5/16 Steel Aluminum Extruded Hole Hex 60-70 inch lbs. 5/16 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex 100-150 inch lbs. 3/8 Steel Steel Nut Hex 150-200 inch lbs. 1/2 Steel Steel Nut Hex 200-250 inch lbs. * Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. CU: Copper AL: Aluminum Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Materials & Finishes Reference Information 43 MATERIALS & FINISHES Materials Steel Quality The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. Steel Sheet 16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90) 14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. Aluminum Extrusion Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 6101-O & 6063-O Aluminum Sheet 3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125 Copper Sheet & Bus Electrolytic copper with tin plating in most applications. Insulating Materials • In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. • Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. • Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. Finish Process Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. Metal Fastners Zinc-coated with a chromate dip. Ratings & Compliance Ratings & Compliance All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1). Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 44 Index INDEX 6003....................................................41 6116....................................................41 243210-LC3R-SP..................................18 303610-CT3R.......................................19 303610-LC3R-SP..................................18 323610-LC3R-SP..................................18 363010-CT3R.......................................19 363016-CT3R.......................................19 363610-CT3R.......................................19 363612-CT3R.......................................19 363612-LC3R-SP..................................18 363616-CT3R.......................................19 423616-CT3R.......................................18 443010-CT3R.......................................19 483612-CT3R.......................................19 483616-CT3R.......................................19 484812-CT3R.......................................19 606013-CT3R.......................................19 A6014-O-400-NKO.............................28 A6015-O-400-NKO.............................28 A7514..................................................40 A7515..................................................40 A7516..................................................40 A7517..................................................40 A7518..................................................40 A7551..................................................40 A8110..................................................40 A8111..................................................40 A8112..................................................40 A9064..................................................40 CP-21...................................................41 CT203611-HC......................................20 CT242411-SC......................................20 CT243011-HC......................................20 CT243011-SC......................................20 CT24329-SC........................................20 CT243611-HC......................................20 CT243611-SC......................................20 CT244811-HC......................................20 CT244811-SC......................................20 CT303011-SC......................................20 CT303611-HC......................................20 CT303611-SC......................................20 CT303614-SC......................................20 CT304811-HC......................................20 CT363611-HC......................................20 CT363611-SC......................................20 CT364211-SC......................................20 CT364811-HC......................................20 CT364811-SC......................................20 CT364814-HC......................................20 CT364814-SC......................................20 CT424211-SC......................................20 CT484811-HC......................................20 CT484811-SC......................................20 CT484814-HC......................................20 K4722..................................................21 K4729..................................................21 K4793..................................................21 K4794..................................................21 K4795..................................................21 K4796..................................................21 K4797..................................................21 K4797..................................................21 K4798..................................................21 K4798..................................................21 K4903..................................................21 K4904..................................................21 K5747..................................................21 K5752..................................................21 K5930..................................................21 K5931..................................................21 K5932..................................................21 K5933..................................................21 MR-2....................................................41 MR2-SS................................................41 MR-4....................................................41 PT48AL................................................18 PT48AR................................................18 PT48L...................................................18 PT48R..................................................18 S1855-O..............................................22 S1856-O..............................................22 S1891-XT.............................................27 S1891-XT.............................................27 S1891-XT.............................................27 S2674-XT.............................................27 S2690-XT.............................................27 S2777-4X.............................................28 S2811-4X.............................................28 S3831-XT.............................................27 S4084-O..............................................31 S8324..................................................40 S9573-X...............................................27 SC6010-O-BL-21.................................10 SC6011-O-BL-21.................................10 TS04-0101...........................................36 TS04-0104...........................................36 TS07-0049...........................................36 TS07-0105...........................................36 TS07-0106...........................................36 TS10-0016...........................................36 TS10-0109...........................................36 TS10-0110...........................................36 TS10-0111...........................................36 TS10-0112...........................................36 U2161-XT.............................................29 U2228-XT.............................................29 U2229-XT.............................................29 U3320-R...............................................24 U3322-R...............................................24 U3340-O..............................................24 U3342-O..............................................24 U3555-R...............................................24 U3565-O..............................................24 U4163-XT-11-LI....................................30 U4166-XT-Z21-LI..................................30 U4468-XT.............................................23 U4468-XT-K4469..................................23 U4490-XL.............................................11 U4492-XL.............................................11 U4493-XL.............................................11 U4494-XL.............................................12 U4496-XL.............................................12 U4497-XL.............................................12 U4523-X-Z11-LI...................................30 U4554-X-Z21-LI...................................30 U4811-O-21.........................................13 U5944-XT.............................................29 U5990-O..............................................23 UC1290-XL............................................5 UC1291-RL............................................5 UC1299-XL............................................5 UC1300-RL............................................5 UC3423-XL............................................8 UC3425-XL............................................8 UC3426-XL............................................8 UC3428-XL............................................8 UC3433-XL............................................8 UC3434-XL............................................8 UC3435-XL............................................8 UC3436-XL............................................8 UC3438-XL............................................8 UC3443-XL..........................................10 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 45 Index UC3444-XL..........................................10 UC3448-XL..........................................10 UC3453-XL..........................................10 UC3458-XL..........................................10 UC7233-XL............................................5 UC7235-XL............................................5 UC7237-XL............................................5 UC7442-RL............................................6 UC7444-RL............................................6 INDEX UC7445-RL............................................6 UC7446-RL............................................7 UC7448-RL............................................7 UC7449-RL............................................7 UC7449-XL-871.....................................9 UC7450-RL............................................7 UC7460-RL............................................7 UC7461-RL............................................7 UC7478-RL............................................6 Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com UC7532-RL............................................7 UC7544-RL............................................5 UC7545-RL............................................5 UC7582-XL............................................5 UC7636-RL............................................7 UCSS3423-O.......................................14 UCSS3433-O.......................................14 46 NOTES Notes Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Notes Utility requirements for this equipment may vary. Always consult the serving utility for their requirements before ordering or installing equipment. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com 47 NOTES Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com INSTRUMENT 4/13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.5-c021 79.154911, 2013/10/29-11:47:16 Create Date : 2014:04:22 10:42:16-05:00 Metadata Date : 2014:04:22 10:42:58-05:00 Modify Date : 2014:04:22 10:42:58-05:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:35154251-de7f-471f-ba12-a9c9454b1171 Original Document ID : xmp.did:860755593A03E2118F05AE0EA9CB0C4F Document ID : xmp.id:c9c1fa68-987f-a44b-9a5c-ed9e5271dac6 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:b06e9c3d-b454-8249-8605-06a0e89924ad Derived From Document ID : xmp.did:A6CB44A428A2E211A442813AF789406F Derived From Original Document ID: xmp.did:860755593A03E2118F05AE0EA9CB0C4F Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:04:22 10:42:16-05:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 48 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools