112170 Catalog

230819-Catalog 230819-Catalog 230819-Catalog 784572 Batch7 unilog cesco-content

2014-07-05

: Pdf 112170-Catalog 112170-Catalog 784572 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 48

Download112170-Catalog
Open PDF In BrowserView PDF
Instrument Rated
Metering Equipment

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

2

MILBANK
OVERVIEW

Milbank Overview
Energy At Work since 1927

Milbank builds solutions that move power for the residential, commercial, industrial, utility and transportation
sectors. Milbank combines more than 85 years of expertise in electrical engineering design and manufacturing
with a commitment to develop and globally implement sustainable, integrated power solutions. Milbank’s
portfolio includes electric metering systems, PowerGen™ wind and solar solutions, and portable power. A thirdgeneration, family-owned business, Milbank is headquartered in Kansas City, Mo. For more information, please
visit milbankworks.com.

METERING
Milbank meter sockets have set the standard for quality since
1927. With a 99.97% quality performance, thousands of
active products to meet your utility’s requirements and tens of
millions of sockets installed across the globe, our products help
keep energy at work. And with 22 stocking locations across the
U.S., and our OneSERT program to help during emergency
situations, our meter sockets are ready to go, wherever the job
may be.

COMMERCIAL & INDUSTRIAL
When it comes to commercial and industrial products, Milbank
has it covered! We offer a complete line of junction boxes,
telephone cabinet covers, transformer cabinets, wireways,
pushbutton enclosures, consoles and thermal management
products. We specialize in custom-built enclosures and are
more than happy to design a solution for your specific project.
Our commercial meter pedestals are easy to install, fast, safe
and secure, and completely customizable.

POWERGEN
Milbank’s standby and portable generators give you the peace
of mind of living life uninterrupted during increasingly frequent
power outages caused by severe weather, high demand and
other situations. Our electric vehicle supply equipment, wind
turbines and power management systems give you reliable and
sustainable ways to reduce both your energy costs and your
impact on the environment.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Table of Contents

3

TABLE OF
CONTENTS

CT Rated Sockets
Plunger bypass features & benefits................................................................................................................................... 4
20 amp CT rated............................................................................................................................................................ 5–8
Prewired CT rated............................................................................................................................................................. 9
Multi-position CT rated.................................................................................................................................................... 10
Lever bypass CT rated............................................................................................................................................... 11–12
Demand side management.............................................................................................................................................. 13
Stainless steel CT rated................................................................................................................................................... 14

CT Cabinets
CT cabinets feature & benefits........................................................................................................................................ 16
Transformer cabinets................................................................................................................................................. 18–20
Stud & lug type mounting racks...................................................................................................................................... 21
Transformer cabinets with factory-installed CT racks................................................................................................. 22–23
Metered transformer cabinet........................................................................................................................................... 24

Transockets
Transockets features & benefits page............................................................................................................................. 26
Transockets................................................................................................................................................................ 27–30

Pedestals
Instrument Rated Pedestal............................................................................................................................................... 31
Instrument Rated Commerical Pedestals......................................................................................................................... 32

Test Switches
Test switches features & benefits.................................................................................................................................... 34
Test switches............................................................................................................................................................. 35–36
Test switch worksheet..................................................................................................................................................... 37

Miscellaneous
Meter Forms..............................................................................................................................................................
Accessories................................................................................................................................................................
Reference Information...............................................................................................................................................
Index..........................................................................................................................................................................

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

38–39
40–41
42–43
44–45

CT Rated Sockets
Plunger Bypass Feature
1

4

4

3
UC7237-RL

2

UC7545-RL

Highlights and Features
		

1

These units are available in a powder coated galvanized G90 steel or aluminum 3R shell.

		

Plunger Bypass: Once meter is removed from socket, plunger bypass disengages and CTs are shunted.

		
		

Connectors: #14 – 4 mechanical connectors provided for ease of connecting CT wires. If ring terminal is desired, use
U prefix rather than UC.

		
		

3

Terminals: Range of 5 to 13 terminal block assemblies available to meet most of your single and three phase
application needs.

4

Ringless/Ring Type: Units available in both ringless or ring type styles.

2

		

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

5

CT Rated Sockets

20 AMP
CT RATED
SOCKETS

20 Amp | 5-13 Terminals

2

2

3

3

1
4

1

1290
1299
7233
7235
7237

1

1291
1300
7544
7545
7582

2 2 2
3

UC7237-RL

UC7545-RL

UC7582-XL

20 Amp | CT Rated Sockets | Ringless | Plunger Bypass
Catalog
Number

Terminals Service Hub

Dimensions

Knockouts

Meter Form

Connectors
CU

D"

W"

H"

1

2

3

5

1

1

⁄4

4

UC1290-XL

5

OH/UG

C.P.

3S

#14 - 10

3 ⁄16

8

14

2

1 ⁄2

1 ⁄4

1

UC1299-XL

6

OH/UG

C.P.

4S

#14 - 10

5

3 ⁄16

8

14

2

1

1 ⁄2

1

1 ⁄4

1

⁄4

UC7233-XL

7

OH/UG

C.P.

7, 14, 15 & 24S

#14 - 10

35⁄16

8

14

2

11⁄2

11⁄4

1

⁄4

UC7235-XL

8

OH/UG

C.P.

5S

#14 - 10

5

3 ⁄16

8

14

2

1

1 ⁄2

1

1 ⁄4

1

⁄4

UC7237-XL

13

OH/UG

C.P.

6, 8, 9S & (ALT) 10S

#14 - 10

3 ⁄16

8

14

2

1 ⁄2

1 ⁄4

1

⁄4

5

1

1

20 Amp | CT Rated Sockets | Ring Type
Catalog
Number

Terminals Service Hub

Meter Form

Connectors
CU

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

5

1

1

3
⁄4

UC1291-RL

5

OH/UG H.O.

3S

#14 - 4 MAX

Plunger

3 ⁄16

8

14

1 ⁄2

1 ⁄4

1

UC1300-RL

6

OH/UG H.O.

4S

#14 - 4 MAX

Plunger

5

3 ⁄16

8

14

1

1 ⁄2

1

1 ⁄4

1

⁄4

UC7544-RL

8

OH/UG H.O.

5S

#14 - 4 MAX

Plunger

35⁄16

8

14

11⁄2

11⁄4

1

⁄4

UC7545-RL

13

OH/UG H.O. 6, 8, 9S & (ALT) 10S #14 - 4 MAX

Plunger

5

3 ⁄16

8

14

1

1 ⁄2

1

1 ⁄4

1

⁄4

UC7582-XL

13

OH/UG

None

3 ⁄16

8

14

1 ⁄2

1 ⁄4

1

⁄4

C.P.

6, 8, 9S & (ALT) 10S

#14 - 10

5

1

Notes
•	Hubs: For proper hub selection, see the hub suffix chart on the accessories page.
•	Bypass: Plunger type bypass automatically closes when meter is removed.
• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are
	 preferred, change catalog prefix to “U” (i.e. UC7544-RL becomes U7544-RL).

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

1

6

20 AMP
CT RATED
SOCKETS

CT Rated Sockets
20 Amp | 1-Piece Cover | w/ Test Switch Provision

1

1

1

1

1

7442
7444
7445
7478

2

UC7478-YL
20 Amp | 1-Piece Cover | CT Rated Socket with Test Switch Provision* | Ringless
Catalog
Number

Terminals Service

Hub

Connectors
CU

Meter Form

Dimensions

Knockouts

D"

W"

H"

1

1

2

UC7442-RL

5

OH/UG H.O.

#14 - #4 Max

3S

4 ⁄8

12

20

1 ⁄4

1

UC7478-RL

6

OH/UG H.O.

#14 - #4 Max

4S

41⁄8

12

20

11⁄4

1

UC7444-RL

8

OH/UG H.O.

#14 - #4 Max

5S

1

4 ⁄8

12

20

1

1 ⁄4

1

UC7445-RL

13

OH/UG H.O.

#14 - #4 Max

6, 8, 9 & (ALT) 10S

41⁄8

12

20

11⁄4

1

1

⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2

Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.
• Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog.
	 Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for
	 details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be
	 sure to provide a copy of your wiring diagram.
• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are
	 preferred, change catalog prefix to “U” (i.e. UC7445-XL becomes U7445-XL).
• *Test Switch Cover: Units on this page are not designated for use with test switch covers without removing test switch
	 bridge prior to installing test switch.
• Test Switch Configurations: See page 34 for standard test switch configurations and page 35 for utility-specified test
	switches.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

7

CT Rated Sockets

20 AMP
CT RATED
SOCKETS

20 Amp | 2-Piece Cover | w/ Test Switch Provision

1

1

1

1

1

2

1

7446
7448
7449
7532

1

1

1

1

2

7450
7460
7461
7636

UC7449-RL
20 Amp | 2-Piece Cover | CT Rated Socket with Test Switch Provision*
Ringless
Ring Type
Terminals Service Hub
Catalog Number Catalog Number

Connectors
CU

Meter Form

Dimensions Knockouts
D" W" H"

1

2

UC7446-RL

UC7450-RL

5

OH/UG H.O. #14 - #4 Max

3S

4 ⁄8 12

20

1 ⁄4

UC7532-RL

UC7636-RL

6

OH/UG H.O. #14 - #4 Max

4S

41⁄8 12

20

11⁄4

1

UC7448-RL

UC7460-RL

8

OH/UG H.O. #14 - #4 Max

5S

4 ⁄8 12

20

1

1 ⁄4

1

UC7449-RL

UC7461-RL

13

OH/UG H.O. #14 - #4 Max 6, 8, 9 & (ALT) 10S 41⁄8 12

20

11⁄4

1

1

1

1

⁄4,1⁄2

1

⁄4,1⁄2

⁄4,1⁄2

⁄4,1⁄2

Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.
• Sealing Rings: Ring type units are supplied with one MR-2 snap-type sealing ring.
• Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog.
	 Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for
	 details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be
	 sure to provide a copy of your wiring diagram.
• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are
	 preferred, change catalog prefix to “U” (i.e. UC7449-XL becomes U7449-XL).
• *Test Switch Cover: Units on this page are not designated for use with test switch covers.
• Test Switch Configurations: See page 34 for standard test switch configurations and page 35 for utility-specified test
	switches.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

8

CT Rated Sockets

20 AMP
CT RATED
SOCKETS

20 Amp | Deeper 51⁄8" Shell | w/ Test Switch Provision

1

1

1 1 1 2

1

3423
3425
3426
3428

UC3423-XL

1

1

1

1

3433
3435
3436
3438
3434

1

UC3433-XL

20 Amp | 2-Piece Cover | CT Rated Socket with Test Switch Provision
Ringless
Ring Type
Connectors
Terminals Service Hub
Catalog Number Catalog Number
CU

Meter Form

Dimensions
D" W" H"

Knockouts
1

2

UC3425-XL

UC3435-XL

5

OH/UG

C.P. #14 - #2 Max

3S

5 ⁄8 12

20

1 ⁄4

1

UC3426-XL

UC3436-XL

6

OH/UG

C.P. #14 - #2 Max

4S

51⁄8 12

20

11⁄4

1

UC3428-XL

UC3438-XL

8

OH/UG

C.P. #14 - #2 Max

5S

5 ⁄8 12

20

1

1 ⁄4

1

UC3423-XL

UC3433-XL

13

OH/UG

C.P. #14 - #2 Max 6, 8, 9 & (ALT) 10S 51⁄8 12

20

11⁄4

1

—

UC3434-XL

15

OH/UG

C.P. #14 - #2 Max

20

11⁄4

1

39S or 76S

1

1

51⁄8 12

1

⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2

Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.
• Sealing Rings: Ring-type units are supplied with one MR-4 screw type sealing ring.
• Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog.
	 Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for
	 details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be
	 sure to provide a copy of your wiring diagram.
• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are
	 preferred, change catalog prefix to “U” (i.e. UC3423-XL becomes U3423-XL).
• Test Switch Cover: Units on this page can be used with clear lexan cover. See accessories page for ordering information.
• Test Switch Configurations: See page 34 for standard test switch configurations and page 35 for utility-specified test
	switches.
• EUSERC Approval: All ring-type items on this page are EUSERC compliant.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Prewired CT Rated Sockets
Factory wired to utility specification

UC7449-XL-871

For field-installable test switches, see page 34 for standard configurations. Test switches can
also be factory installed without prewiring. Consult factory for details.
Milbank’s CT Rated meter sockets are also available with factory prewiring and customspecified test switches. For factory prewiring and custom test switch configurations, see the
worksheet on page 35 and consult factory for details.
Available for both ring type and ringless applications.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

9

PREWIRED
CT RATED
SOCKETS

10

Multi-Position CT Rated Sockets

TWO
POSITION
CT RATED
SOCKETS

20 Amps | w/ Test Switch Provision

UC3453-XL

1

1

SC6011-O-BL-21

1

2

1

3443 3453
3444 3458
3448

1

1

1

1

1

2

1

1

1

1

6010

2

1

1

1

1

1

2

1

1

1

1

2

1

1

1

1

6011

2

20 Amps | Multi-Position CT Rated Sockets | Ringless
Catalog
Number

UL
Connectors
Positions Terminals Service Hub
Listed
CU

Meter Form

UC3458-XL

Yes

2

8

OH/UG C.P. #14 - #4 Max

UC3453-XL

Yes

2

13

OH/UG C.P. #14 - #4 Max 6, 8, 9 & (ALT) 10S

SC6010-O-BL-21

No

1

13

SC6011-O-BL-21

No

2

13

Dimensions
D"

W"

H"

Knockouts
1

2

5

25 ⁄16 20

1 ⁄4

1

5

251⁄16 20

11⁄4

1

UG

Blank #14 - #4 Max 6, 8, 9 & (ALT) 10S 4 ⁄8 36 ⁄16 20

1

1 ⁄2

1

UG

Blank #14 - #4 Max 6, 8, 9 & (ALT) 10S 41⁄8 4811⁄16 20

11⁄2

1

5S

1

1

7

1

⁄4,1⁄2
⁄4,1⁄2
⁄2,3⁄4
⁄2,3⁄4

20 Amps | Multi-Position CT Rated Sockets | Ring Type
Catalog
Number

UL
Positions Terminals Service Hub
Listed

Connectors
CU

Meter Form

Dimensions
D"

Knockouts

W"

H"

1

2

UC3448-XL

Yes

2

8

OH/UG C.P.

#14 - #4 Max

5S

5 ⁄8 25 ⁄16

20

2

1

UC3443-XL

Yes

2

13

OH/UG C.P.

#14 - #4 Max

6, 8, 9 & (ALT) 10S

51⁄8 251⁄16

20

2

1

UC3444-XL

Yes

2

15

OH/UG C.P.

#14 - #4 Max

39S or 76S

51⁄8 251⁄16

20

2

1

1

1

⁄4,1⁄2
⁄4,1⁄2
⁄4,1⁄2

Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessory page.
• Sealing Rings: Ring-type units are supplied with one MR-4 screw type sealing ring.
• Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch
	 model and number, and meter form number. Please be sure to provide a copy of your wiring diagram.
• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are
	 preferred, change catalog prefix to “U” (i.e. UC3453-XL becomes U3453-XL).
• The SC6010 and SC6011 include a section for additional electronic components. Remote CT cabinet required.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

11

Lever Bypass CT Rated Sockets

80 AMP
LEVER BYPASS
CT RATED

80 Amps | Ringless | 600 VAC

4

5 2

1

2

3

4490
4492
4493

2

U4490-XL

U4493-XL

80 Amps | Transformer Rated Sockets | Lever Bypass | Ringless
Catalog
Number

Terminals Service Hub

Connectors
CU

Bypass

Dimensions

Knockouts

D"

W"

H"

1

2

7

3

U4490-XL

6

OH/UG

C.P.

#14 - #4 Max

Lever

4 ⁄8

10

18 ⁄2

3

1 ⁄2

1

U4492-XL

8

OH/UG

C.P.

#14 - #4 Max

Lever

7

4 ⁄8

10

18 ⁄2

3

1

1 ⁄2

1

U4493-XL

13

OH/UG

C.P.

#14 - #4 Max

Lever

4 ⁄8

10

18 ⁄2

3

1 ⁄2

1

7

1
1

1

1

1

4

3

⁄2, ⁄4

3

3

⁄2, ⁄4

3

⁄2, ⁄4

3

3

5

⁄4

1

⁄4

1

⁄4

⁄4

1

⁄4
⁄4

Notes
• Hubs: For proper hub selection, see the hub suffix chart on the accessories page.
• Bypass: Lever operates current bypass device and also supplies clamping action on current meter spades.
• Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#10) are
	 preferred, change catalog prefix to “U” (i.e. UC4490-XL becomes U4490-XL).
• Removable Handle: When removable handle is desired add suffix “-RH” to catalog number (i.e. U4493-XL becomes
	 U4493-XL-RH).
• Replacement Removable Handle: When a replacement removable handle (RH) is required order part #Z706850-SC.
	 Replacement handle will only work with factory ordered RH units.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

12

Lever Bypass CT Rated

20 AMP
LEVER BYPASS
CT RATED

20 Amp | Ringless | w/ Test Switch Provision

1

1

1

1

1 2

4494
4496
4497

U4497-XL

U4496-ZL-WC-41

20 Amp | Ringless | 1-Piece Cover | CT Rated Socket with Test Switch Provision
Catalog Number

Terminals Service

Hub Connectors CU

Bypass

Dimensions

Knockouts

D"

W"

H"

1

7

2

U4494-XL

6

OH/UG

C.P.

#14 - #4 Max

Lever

4 ⁄8

12

22

1 ⁄2

1

U4496-XL

8

OH/UG

C.P.

#14 - #4 Max

Lever

47⁄8

12

22

11⁄2

1

⁄4,1⁄2

U4497-XL

13

OH/UG

C.P.

#14 - #4 Max

Lever

47⁄8

12

22

11⁄2

1

⁄4,1⁄2

1

⁄4,1⁄2

Notes
• Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch
	 model and number, and meter form number. Please be sure to provide a copy of your wiring diagram.
• Connectors: Units are supplied with mechanical type connectors (#4 max).
• Test Switch Cover: Units on this page can be used with clear lexan cover. See accessories page for ordering information.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

13

Demand Side Management

DEMAND
SIDE
MANAGEMENT

200/20 Amps | 4 Terminals | Ringless

3

1

1 4 1

1

3

2

4811

3

U4811-O-21

Application
The right position is used for sub-metering by the serving utility when a special electric rate is given to customers for devices
that can shed load during high energy demand. Contact your local utility for more information.

Features
• Low voltage compartment in lower right corner
• Left position is a 200 amp, 4 terminal heavy duty lever bypass interior
• Right position is 20 amp rated with a fifth terminal in the 9 o’clock position and a plunger bypass
• Right position is pre-wired to the terminal strip for easy installation

200/20 Amps | 4 Terminals | Two Positions | Off-Peak Metering
Connectors / CU

Catalog
Number

Service

U4811-O-21

UG

Left Side
Right Side
(Line & Load)
#6-350

Terminal Strip

Dimensions
Bypass
Lever/Plunger

Knockouts

D"

W"

H"

1

2

47⁄8

21

18

2

11⁄4

Notes
• Fifth Terminal: For field installed fifth terminal on left (200 amp) side, order catalog number K3866.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

3
⁄4

3

4
⁄4,1⁄2

1

14

Stainless Steel CT Rated

STAINLESS
STEEL
CT RATED

20 Amps | with Test Switch Provision

3423

3433

UCSS3433-O

(shown as UCSS3433-O-141
pre-wired unit)

20 Amps | Ringless | CT Rated Socket with Test Switch Provision | Stainless Steel
Catalog Number

Terminals

Service

Hub

Connectors CU

Cover

UCSS3423-O

13

OH/UG

Blank

#14 - #2 Max

2-Piece

Dimensions
D"

W"

H"

51⁄8

12

20

Knockouts
None

20 Amps | Ring Type | CT Rated Socket with Test Switch Provision | Stainless Steel
Catalog Number

Terminals

Service

Hub

Connectors CU

Cover

UCSS3433-O

13

OH/UG

Blank

#14 - #2 Max

2-Piece

Dimensions
D"
51⁄8

W"

H"

12

20

Knockouts
None

Notes
• For Conduit Opening Applications: All conduit openings have dimples provided to center location. Top conduit opening
	 must have water-tight hub installed.
• Other Stainless Steel Products: Most units available in stainless steel—contact Milbank for details.
• EUSERC Approval: The UCSS3433-O is EUSERC compliant.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Notes

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

15
NOTES

CT Cabinets
Features & Benefits

1

5
4

3

2

6

U5990-O
(Window-style CT—
not included)

Highlights and Features

1

Powder Coat Painted NEMA 3R Shell: As with all Milbank products, our enclosures are constructed of G90U
galvenized steel and finished with attractive, light gray, baked powder coating. Our state-of-the-art finish combines
epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a
durable, non-fading finish.

2

Three-Point Latching Handle & Locking Mechanism: Padlocking handle with three-point latching system allows for
easy locking and securing of the unit.

3

Hinged Double Doors: Hinged overlapping double doors enhance ease-of-access and are secured with three-point
latching system.

4

Bar-Type CT Rack: Includes pre-placed studs to mount bar-type CTs. Withstand rating is 50K.

5

Lugs: Line, load and neutral rack lugs are single 600 kcmil or twin 250 kcmil.

6

Grounding Lug: Single position, 350 kcmil.
Some units available in stainless steel—contact Milbank for details.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Notes

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

17
NOTES

18

Current Transformer Cabinets

TRANSFORMER
CABINETS

Continuous Hinge | Padlock Provision

Current Transformer Cabinets | Type 3R
Dimensions

Panel Size

Catalog
Number

Gauge
Steel

W"

H"

D"

W”

H”

Painted Steel Panel
Catalog Number

Wood Backboard
Catalog Number

243210-LC3R-SP

14

24

32

10

21

29

A-24P32

A-24P32W

303610-LC3R-SP

14

30

36

10

27

33

A-36P30

A-36P30W

323610-LC3R-SP

14

32

36

10

29

33

A-32P36

A-32P36W

363612-LC3R-SP

14

36

36

12

33

33

A-36P36

A-36P36W

423616-CT3R

14

42

36

16

39

33

A-42P36

A-42P36W

PT Cabinets
Dimensions

Catalog
Number

D"

W"

PT48L

8

8

PT48AL

8

12

36

2 ⁄2" - right side

Aluminum

PT48R

8

8

271⁄2

21⁄2" - left side

Steel

PT48AR

8

12

36

2 ⁄2" - left side

Aluminum

Notes

Knockout

H"

271⁄2 21⁄2" - right side
1

1

Material
Steel

PT48AR*

S7860

• Features: Supplied with studs, continuous hinge and padlock provision. Steel panels and plywood backboard are optional.
• LC3R-SP: Indicates a single door with two padlockable wind handles.
• *PT48: PT48L and PT48AL has mounting emboss on the right side to be mounted on left side of CT cabinet. PT48R and 	
	 PT48AR have mounting emboss on left side to be mounted on right side of CT cabinet.
• Pole Mounting: For pole mounted CT rack applications, order catalog number S7860.
• There are other sizes of outdoor transformer cabinets available, contact Milbank or refer to our enclosures catalog for details.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

19

Transformer Cabinets

TRANSFORMER
CABINETS

CT and PT Cabinets
Application

• For use as a current transformer cabinet or panel enclosure.
• For outdoor use to provide protection against rain, sleet
	 and snow, or indoor use to protect against dripping water.

Construction
• Enclosure and cover manufactured from 16 or 14 gauge
	 G90U galvanized steel.
• The doors are overlapping with no center post.
• Continuous door hinge with stainless steel 	hinge pins.
• Three point pad-lockable handle.
• Panel mounting studs provided for optional back panels.
• Drip shield top and seam-free sides, front and back.

363612-CT3R

Finish
• ANSI 61 gray polyester powder coating over phosphatized
	 G90U galvanized steel.

Current Transformer Cabinets | Panel Enclosure
Catalog
Number

Weight

303610-CT3R

Dimensions

Steel Panel Catalog # Wood Panel Catalog #

W"

H"

D"

99

30

36

10

A-36P30

A-36P30W

363010-CT3R

99

36

30

10

A-36P30

A-36P30W

363016-CT3R

121.5

36

30

16

A-36P30

A-36P30W

363610-CT3R

113

36

36

10

A-36P36

A-36P36W

363612-CT3R

118

36

36

12

A-36P36

A-36P36W

363616-CT3R

139

36

36

16

A-36P36

A-36P36W

443010-CT3R

116

44

30

10

A-30P44

A-30P44W

483612-CT3R

147

48

36

12

A-48P36

A-48P36W

483616-CT3R

163

48

36

16

A-48P36

A-48P36W

484812-CT3R

210

48

48

12

A-48P48

A-48P48W

606013-CT3R

274

60

60

13

A-60P60

A-60P60W

Notes
• Wall or Pole Mount: For wall or pole mount CT rack order S7860. This unit accomodates 3 donut style CTs. The 		
	 removable cover makes wiring much easier.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

20

TRANSFORMER
CABINETS

Current Transformer Cabinets
Compatible with Field Installable Racks

Screw Cover Current Transformer Cabinets
* Catalog Number

*
*
*
*
*
*
*
*
*
*

CT24329-SC
CT242411-SC
CT243011-SC
CT243611-SC
CT244811-SC
CT303011-SC
CT303611-SC
CT303614-SC
CT363611-SC
CT364211-SC
CT364811-SC
CT364814-SC
CT424211-SC
CT484811-SC

Dimensions
W" H" D"
C, M
24 32 9
A4, C, M, Q
24 24 11
A4, C, M, Q
24 30 11
A4, C, J, M, Q
24 36 11
A, C, D, J, M, Q
24 48 11
A4, B4, C, E, L, M, Q, R
30 30 11
A4, B4, C, E, J, K, L, M, Q, R
30 36 11
A4, B4, C, E, J, K, L, M, Q, R
30 36 14
A4, B4, C, E, J, K, L, M, Q, R
36 36 11
A4, B4, C, E, J, K, L, M, Q, R
36 42 11
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R 36 48 11
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R 36 48 14
A4, B4, C, E, J, K, L, M, Q, R
42 42 11
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R 48 48 11
Compatible CT Racks
(see next page for matching code)

Front
Cover
1 Piece
1 Piece
1 Piece
1 Piece
1 Piece
1 Piece
1 Piece
1 Piece
1 Piece
2 Pieces
2 Pieces
2 Pieces
2 Pieces
2 Pieces

CT24329-SC

Hinge Cover Current Transformer Cabinets
* Catalog Number

*
*
*
*
*
*
*
*

CT203611-HC
CT243011-HC
CT243611-HC
CT244811-HC
CT303611-HC
CT304811-HC
CT363611-HC
CT364811-HC
CT484811-HC
CT364814-HC
CT484814-HC

Compatible CT Racks
(see next page for matching code)
C
A4, C, M, Q
C, M
A, C, D, J, M, P, Q
A4, B4, C, E, J, K, L, M, Q, R
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R
A4, B4, C, E, J, K, L, M, Q, R
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R
A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R

Dimensions Front
W" H" D" Cover
20 36 11 1 Piece
24 30 11 1 Piece
24 36 11 1 Piece
24 48 11 1 Piece
30 36 11 1 Piece
30 48 11 1 Piece
36 36 11 1 Piece
36 48 11 1 Piece
48 48 11 2 Pieces
36 48 14 2 Pieces
48 48 14 2 Pieces

CT203611-HC

Notes
• EUSERC Approval: Units denoted with an asterisk (*) are EUSERC compliant.
• Enclosure: These units are rated Type 3R, powder coat painted and constructed of galvanized steel.
• Mounting Rack: Select CT mounting rack from the next page.
• Mounting: 1⁄4-20 welded studs spaced to accept mounting racks.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

21

CT Cabinet Mounting Racks

CT CABINET
MOUNTING
RACKS

Stud & Lug Types

K4797

K4798

K4729

K5932

K4793

K5933

K5930

Screw Cover Current Transformer Cabinets
*

Code

Catalog
Number

SCCR
Rating

Amps

Volts

Type of
Service

*

A4

K4797

50K

400

600

1Ø3W

1

*

A

K4797

50K

800

600

1Ø3W

1

*

B4

K4798

50K

400

600

3Ø4W

1

*

B

K4798

50K

800

600

3Ø4W

1

*

C

K4793

10K

201–400

600

1Ø3W

1

*

D

K4795

10K

401–800

600

1Ø3W

1

*

E

K4794

10K

201–400

600

3Ø4W

1

*

F

K4796

10K

401–800

600

3Ø4W

1

*

G

K4729

50K

800

600

1Ø3W

(3) #4-600 or (6) #1-250

*

H

K4722

50K

800

600

3Ø4W

(3) #4-600 or (6) #1-250

*

J

K4903

50K

400

600

1Ø3W

(1) #4-600 or (2) #1-250

*

K

K4904

50K

400

600

3Ø4W

(1) #4-600 or (2) #1-250

L

K5747

50K

800

600

3Ø4W

Termination Type
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers

M

K5752

50K

800

600

1Ø3W

Line: 1⁄2"-13 studs on 13⁄4" centers
Load: (3) #4-600 or (6) #1-250
Line: 1⁄2"-13 studs on 13⁄4" centers
Load: (3) #4-600 or (6) #1-250

N

K5930

50K

800

600

3Ø4W

(3) #4-600 or (6) #1-250

P

K5931

50K

400

600

1Ø3W or 3Ø3W

Q

K5932

50K

400

600

1Ø3W or 3Ø3W

1

R

K5933

50K

400

600

3Ø4W

1

(1) #4-600 or (2) #1-250
⁄2"-13 studs on 13⁄4" centers
⁄2"-13 studs on 13⁄4" centers

Notes
• EUSERC Approval: Units marked with an asterisk are EUSERC compliant.
• CT racks on this page are for use with bar type CTs.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

K4722

K5931

22

Current Transformer Cabinets

TRANSFORMER
CABINETS

with Factory Installed CT Racks | 600 VAC

Connector
detail
S1855-O

Current Transformer Cabinets | Non-UL Approved
Dimensions

Catalog Number

Amps

Hub

Gauge
Steel

Connectors
CU/AL

D"

W"

H"

S1855-O

400–800

Blank

12

(3) 3/0-750 kcmil per phase

12

36

36

S1856-O

800–1200

Blank

12

(5) 3/0-750 kcmil per phase

12

48

48

Notes
• Features: These enclosures have three-point locking handles, liftoff hinges with stainless steel pins and two doors.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

23

Current Transformer Cabinets

400 & 800 AMP
TRANSFORMER
CABINETS

400 & 800 Amps

U4468-XT

U5990-O

Current Transformer Cabinets | 3Ø
Catalog Number
U4468-XT
U4468-XT-K4469
U5990-O

Ampacity Wiring Chart
Amps

Wire Qty.
Per Phase

400
400
800
800

1
2
2
4

800

3

Aluminum
Conductor

Copper
Conductor

Hub

—
600 kcmil
(2) C.P.
250 kcmil
3/0
—
600 kcmil
(2) C.P.
250 kcmil
3/0
600 kcmil 600 kcmil
Blank
or 2-250 or 2-250

Dimensions
D"

W"

H"

10

24

45

10

24

45

10

36

36

Notes
• Hubs: U4468 is supplied with two closing plates as standard. To order hubs, refer to the accessories section.
• Studs: The U4468 is supplied with 1⁄2"-13 twin studs with hex nuts with Belleville washers to mount bar-type transformers.
• 800 Amp Conversion Kit: To convert U4468 from 400 amps to 800 amps, order catalog number K4469.
• Padlock: The U4468 is provided with a padlockable 2-point latch. The U5990 is provided with a padlockable handle with
	 3-point latching mechanism.
• Withstand Rating: 50K SCCR available when conductors are lashed per instructions on label.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

24

Metered Transformer Cabinets

METERED
TRANSFORMER
CABINETS

Screw Cover | Ring Type

1

1 2 1

3320 3342
3322 3555
3340 3565

S3565-O

Metered Transformer Cabinets | Ring Type
Catalog
Number

Terminals Service Hub

Dimensions

Knockouts

Compatible CT Racks
(see pg. 21 for matching code)

Type of
Service

D"

W"

H"

1

2

U3320-R

6

OH

H.O.

A, C, D, J, L, M

1Ø3W

11

24

42

4

1

U3322-R

13

OH

H.O.

B, E, F, G, H, L, M

3Ø4W Y or Δ

11

36

42

4

1

U3555-R

15

OH

H.O.

B, E, F, G, H, L, M

3Ø4W Y or Δ

11

36

42

4

1

U3340-O

6

UG

Blank

A, C, D, J, L, M

1Ø3W

11

24

52

4

1

U3342-O

13

UG

Blank

B, E, F, G, H, L, M

3Ø4W Y or Δ

11

36

52

4

1

U3565-O

15

UG

Blank

B, E, F, G, H, L, M

3Ø4W Y or Δ

11

36

52

4

1

Notes
• Meter Socket: 20 amp current transformer meter socket built in.
• Enclosure: NEMA Type 3R with screw cover.
• Current Transformer Mounting: 1⁄4–20 welded studs.
• Hubs: For proper hub selection, see hub suffix chart in the accessories section.
• Sealing Rings: Supplied with MR-4 screw type sealing ring.
• Lugs: For mounting rack information, refer to page 21.
• Test Switches: These units include test switch provision to mount above or below CT rack. Will accept 7 or 10 pole test
	switches.
• EUSERC Approval: All units on this page are EUSERC compliant.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Notes

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

25
NOTES

Transockets
Features & Benefits
4

6
1

2
3
5
AP6014-O-400-NKO-21

Highlights and Features
Transocket Overhead/Underground Capabilities: From the factory, the rack is oriented for underground
applications but can be rotated 180° for overhead applications. The neutral lugs can be mounted on the side for
overhead applications. The VT pack mounting bridge moves from the top to the right side for overhead applications.

1

NEMA 3R Aluminum Shell: The alumnium shell reduces the overall weight of the unit compared to a steel shell.
Shell is powder coated.

2

Meter Socket & Test Switch on Swinging Door: Unit includes a 13-terminal CT-rated block. An 8-terminal block
option is also available. Includes a 10-pole test switch. A 7-pole test switch option is also available. Factory pre-wired
to conform to individual utility specifications.

3

Utility-Specific Wiring Harness: Wiring harness is color configured and wired per the utility specifications.

4

VT Pack Mounting Bridge: VT pack mounting bridge allows for installation of VT packs.

5

Wall Mount Bracket: Provides an easier means of installation for one installer, who can premount the bracket and
then hang the unit onto the wall bracket.

6

Stainless Steel Liftoff Handles: The durable, rust-resistant hinged handles lay flat against the front.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

27

Transockets

400–600 AMP
TRANSOCKETS

400–600 Amps | Ringless | 600 VAC

S9573-X

S2674-XT
2

S1890-XT

2

3
1

1

1

1

2

2

9573

3

1

2

2
3

1

3

1

2674
2690
3831

2

1

1
2

1

2

1

1890
1891
3912

400 Amps | Transockets | Bar Type CTs Only | Ringless | 600 VAC
Dimensions

Knockouts

Catalog
Number

Terminals

Meter
Form

Hub

CTs Qty.
and Ratio

Termination
Type

D"

W"

H"

1

S9573-X

6

4S

C.P.

(2) 200/5

Lay-in lugs

53⁄4

191⁄2

27

31⁄2

S3831-XT

6

4S

(2) C.P.

(2) 200/5

Mechanical lugs 111⁄4

18

30

S2690-XT

8

5S

(2) C.P.

(2) 200/5

Mechanical lugs 11 ⁄4

18

S2674-XT

13

8S

(2) C.P.

(3) 200/5

Mechanical lugs 111⁄4

18

1

2

3

⁄4,1⁄2

—

4

31⁄2

1

30

4

1

3 ⁄2

1

30

4

31⁄2

1

1

600 Amps | Transockets | With PTs and Donut Type CTs | Ringless | 600 VAC
Catalog
Number

Terminals

Meter
Form

Hub

PTs Qty.
CTs Qty.
and Ratio and Ratio

S1891-XT

8

5S

(2) C.P.

(2) 4:1

(2) 200/5

S3912-XT-21

13

8S

(2) C.P.

(2) 4:1

(2) 200/5

S1890-XT

14

5S

(2) C.P.

(2) 4:1

(2) 200/5

Termination
Type
Lugs mounted directly to
current transformer
Lugs mounted directly to
current transformer
Lugs mounted directly to
current transformer

Dimensions

Knockouts

D" W" H"

1

2

1

9 ⁄2

18

24

2 ⁄2

1

11

1

9 ⁄2

18

24

1

2 ⁄2

1

11

9 ⁄2

18

24

2 ⁄2

1

11

1

1

Notes
• Hubs: To order hubs as extra, refer to the hub suffix chart in the accessories section.
• Prewiring: Units supplied prewired with test switch and transformers in place. Contact factory if prewiring is desired.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

3

1

⁄16
⁄16
⁄16

28

Transockets

TRANSOCKETS

Compatible with CTs, PTs, or VT Packs

1

1

1

1

2777
2811

S2777-4X
(shown factory prewired)

A6014-O-400-NKO
(shown factory prewired)

400–1000 Amps | 8 & 13 Terminals | Ringless | Transocket
Catalog Number

Terminals Service

Phase

Test
Switch

Hub

VT Pack CTs Qty.
Provision & Ratio

Dimensions
D"

W"

H"

Knockouts

A6015-O-400-NKO

8

OH/UG 1Ø or 3Ø3W 7-pole Blank

Yes

(2) 400/5 121⁄16

36

37

None

A6014-O-400-NKO

13

OH/UG

Yes

(3) 400/5 12 ⁄16

36

37

None

3Ø4W

10-pole Blank

1

Notes
• Shell: Shell is unpainted aluminum and 3R rated.
• Prewiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and
	 provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio.
• VT Pack Provision: VT pack bridge included; VT pack not included.
• Removable/Rotatable CT Rack: These units include a CT rack which can be rotated 180 degrees for both overhead or
	 underground applications.
• Wall Mount Bracket: Bracket included for ease of hanging and installation.
• Lugs: Lugs are included with these units.

1600 Amps | 14 Terminals | Ringless | 3Ø4W | Transocket
Catalog Number

Terminals Service Test Switch

Hub

PTs Quantity CTs Quantity
& Ratio
& Ratio

Dimensions

Knockouts

D"

W"

H"

1

S2777-4X

14

OH/UG

10-pole

(4) C.P.

(2) 2.5:1

(3) 400/5

14

30

42

1

S2811-4X

14

OH/UG

10-pole

(4) C.P.

None

(3) 400/5

14

30

42

1

⁄2
⁄2

Notes
• Hubs: Units supplied with 4 closing plates as standard. To order hubs as extra, refer to the accessories page.
• Pre-wiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and
	 provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio, and PTs if applicable.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

29

Transockets

400 AMP
TRANSOCKETS

400 Amps | 600 VAC

1

1

1

1

1
1

2

1
2

2

2161
2228
2229
5944
U2161-XT

U5944-XT
(shown factory prewired)
400 Amps | 6–13 Terminals | Ringless | Transockets
Catalog Number

Terminals Service

Front
Cover

Dimensions

Knockouts

Phase

Test Switch

Hub

D"

W"

H"

1

2

1Ø

Provision

(2) C.P.

12

24

34

4

1

U2228-XT

6

OH/UG Hinged

U2229-XT

8

OH/UG Hinged 1Ø or 3Ø3W

Provision

(2) C.P.

12

24

34

4

1

U2161-XT

13

OH/UG Hinged

3Ø4W

Provision

(2) C.P.

12

24

34

4

1

U5944-XT

13

OH/UG

3Ø4W

Provision

(2) C.P.

12

24

34

4

1

Lift-off

Notes
• Hubs: Units are supplied with two closing plates as standard. To order hubs as extra, refer to the accessories page.
• Shell: Shell is powder-coat painted G90 galvanized steel and 3R rated.
• Pre-wiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and
	 provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio. There is no provision for PTs in
	 this unit.
• Studs: 1⁄2"-13 twin studs are supplied to mount bar type transformers. Hex nuts with Belleville washers are also supplied.
• Lugs: Lugs are included with these units.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

30

Transockets

200/400/800 AMP
TRANSOCKETS

200/400/800 Amps | 600 VAC

3

4163
4166

2

1

1

1

3

1

2

1

1

1

4154

1

3

U4163-XT-11-LI

2

2

1

1

U4163-XT-11-LI

4554

1

200/400/800 Amps | 6 & 13 Terminals | Transockets | Ringless
Catalog Number

Terminals Service

Amps

Hub

Connectors
Line

Load

Phase

Dimensions

Knockouts

D"

W"

H"

1

2

U4554-X-Z21-LI

6

OH/UG

200/400

C.P.

#4-600 #4-600

1Ø

10

21

41

4

11⁄4

3

U4166-XT-Z21-LI

6

OH/UG

400/800

C.P.

#4-600 #4-600

1Ø

10

26

51

4

1

1 ⁄4

3

U4523-X-Z11-LI

13

OH/UG

200/400

C.P.

#4-600 #4-600

3Ø

10

21

41

4

1

1 ⁄4

3

U4163-XT-11-LI

13

OH/UG

400/800

C.P.

#4-600 #4-600

3Ø

10

26

51

4

1 ⁄4

3

1

3*
⁄8
⁄8
⁄8
⁄8

Notes
• *Knockout #3: This is a 3⁄8" hole with plastic plug, not a concentric knockout.
• Lugs: Lugs are provided and are rated up to single 600 kcmil - #4 AWG.
• Short Circuit Current Withstand Rating: These units have a 50K short circuit current withstand rating.
•	Units furnished with 1/2"-13 studs, washers and hex nuts and bolt with conical washer for CT mounting.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

31

Instrument Rated Pedestal
20 Amps | 13 Terminals | With Test Switch Provision

1

1

S4084-O
Ringless | Instrument Rated Pedestal | With Test Switch Provision
Catalog
Number

Terminals

Hub

S4084-O

13

Blank

Meter Form

Connectors
Bypass
CU

6, 8, 9 & (ALT) 10S #14 - #4 Max

None

Dimensions

Knockouts

D"

W"

H"

1

41⁄8

12

58

11⁄4

Notes
• Contact factory for details.
• Also available in 6 & 8 terminals.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

INSTRUMENT
RATED
PEDESTAL

32

INSTRUMENT
RATED
PEDESTAL

Instrument Rated Commercial Pedestals
Attractive | Easy to Install | Secure | Cost-effective

Milbank Commercial Pedestals are pad-mounted, weatherproof electrical enclosures consisting of a utility
pull section with optional meter socket, and a customer section containing distribution and control equipment.
Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when
underground remote site power distribution and control equipment is required, replacing unsightly and
inefficient strut and backboard structures.

Standard Features
• Type 3R rainproof, vandal-resistant cabinet of powder-coated steel (aluminum or stainless steel also available)
• UL-listed as enclosed industrial control equipment (UL508)
• Isolated lockable & sealable utility metering and lug landing sections
• Lockable customer section for distribution and control equipment with internal deadfront
• Print pocket inside customer section door contains wiring schematics and installation instructions
• All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws)

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Notes

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

33
NOTES

Test Switches
Features & Benefits

1
5

6
3
2
4
Highlights and Features

1

Handle Color Options: Standard colors are black for current and red for potential. Many non-standard colors are
available—contact Milbank for details. Handle material is polypropylene.

2

45 Degree Stops: 90 degree bends on 45 degree stops are standard. 180-degree bends are available where
additional strength is required.

3

Test Switch Barriers: Test switch barriers are made of polycarbonate as standard.

4

Test Switch Covers: Polycarbonate (clear or black). Test switch cover is clear when factory-installed unless otherwise
specified.

5

Test Switch Base: Test switch bases are red as standard and made of glass polyester.

6

Arboron Test Switch Base & Barriers Option: Base and barriers are available in Arboron, a thicker and more rigid
material that provides extra strength.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

35

Test Switches

TEST
SWITCHES

Details & Test Switch Covers

Switch Blades
Two dimples coined into one side of the
switch blade ensure positive contact in
corrosive, sooty environments—even
after years of inactivity.
Test Switch Covers
Standard test switch covers are made
from impact resistant clear thermal
plastic which has excellent tracking and
moisture resistant properties. If covers
are required, add suffix -WC (with cover)
to the catalog number or order separately
catalog number K3388. Black flush
mount covers are also available. Order
catalog number K3388-BLK-FL. 10 pole
base only.

Test Switch Base
The base is molded from a high strength,
fiberglass reinforced, thermoset
polyester. This material is track resistant,
flame retardant and has low water
absorption qualities. Bases are available
in 7 pole and 10 pole sizes.
Switch Jaws
The switch blade jaw clips are constructed
from spring grade copper alloy. The
material and design ensure excellent
contact which prevents overheating.

Polarity Barrier
For maximum protection potential
circuits are supplied with permanently
mounted barriers made from high tensile
strength polycarbonate.
Current Carrying Parts
Highly conductive copper and copper
alloy materials are used on all current
carrying parts. This ensures conductivity
and deters corrosion. Spring grades are
used where appropriate. Plating is
available if required. Contact general
offices to special order.

Nickel Plating Option
Corrosion-resistant test switches with
nickel plating are available as an option.

Standard Cover
Flush Mount Cover (Black)
Socket shells must be 51⁄8" deep
-ORmust not have test switch bridge
mounted on back
in order to support a cover.

Factory Installed: For cover installed add the suffix -WC or -WCFL to the catalog number of desired test switch.
Field Installed: For field installed cover order kit number K3388 or K3388-BLK-FL.
The Milbank test switch is designed to meet the critical requirements of the electric utility industry. Not only do
they meet EEI, ANSI C12.9, and UL standards but they combine several special features giving the Milbank test
switch increased safety, durability and reliability. One such feature is our unique switch blade contact points
which cut through residue that builds up after years of service. Another distinction is our polarity barrier which is
designed to be flexible as well as offer exceptional insulating qualities. Our test switches are constructed from the
latest materials available using modern fabricating and assembly methods.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

36

Test Switches

TEST
SWITCHES

4, 7 & 10 Pole

3 1/2"

7 1/2"

3 1/2"

9 1/2"

Key

Catalog
Number

4-Pole

P

Potential Switch

TS04-0101

X

P

Pn

X

C+

C

X

C+

Line side current switch with
short circuit assembly

TS04-0104

X

C+

C

X

P

Pn

X

C

Load side current switch
with test jack assembly

N

Neutral bar (no switch)

Pn

Neutral Potential Switch

X

Unused Position on base

C

C+

C

Catalog
Number

7-Pole

TS07-0105

P

P

Pn

C+

Insulating barrier, isolates
both sides of switch
Custom Pole Arrangements:
The key may be used to diagram
your own pole arrangement. Be
sure to specify base size and
whether all C+ line side, current
switch / shunt circuit assemblies
are to be bussed together. The
catalog numbers shown above
are connected in line-load pairs;
therefore, if bussing is required,
different catalog numbers will
apply.

Catalog
Number

7-Pole on a 10-Pole Base

TS07-0049

P

X

P

X

Pn

X

C+

C

C

C+

TS07-0106

X

P

C+

C

P

C+

C

Pn

X

X

Catalog
Number

10-Pole

TS10-0109

P

P

P

Pn

C+

C

C+

C

C+

C

TS10-0110

P

C+

C

P

C+

C

P

C+

C

Pn

TS10-0111

P

P

P

Pn

C

C+

C

C+

C

C+

TS10-0112

C+

C

C+

C

C+

C

P

P

P

Pn

TS10-0016

P

P

P

Pn

C

C+

C

C+

C

C+

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

37

Test Switch Worksheet

TEST SWITCH
WORKSHEET

Electronic version available at milbankworks.com

Customer Name:_________________________________________________________________
Address:________________________________________________________________________
________________________________________________________________________________
Phone / Fax #: __________________________________________________________________

TEST SWITCH BASE

Handle Color Key
BK

Black

P

Purple

Y

Yellow

GN

The base is molded from a high strength,
fiberglass reinforced, thermoset polyester.
This material is track-resistant, flame-retardant
and has low water absorption qualities. Bases
are available in two standard sizes following
NEMA mounting classifications.

Green

R

Red

BL

Blue

W

White

BKS

Black Stripe

BR

Brown

GR

Grey

O

Orange

WS

White Stripe

Pole Position Chart
1

2

3

4

5

6

7

8

9

10

Special Features
Feature

1

2

3

4

5

6

7

8

9

10

45° Angle Stops
Ganged Handles (C)
Bussing
Colored Handles
Engineering Information: _________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________

Key
P

Potential Switch

C+

Line side current switch with
short circuit assembly

C

Load side current switch
with test jack assembly

N

Neutral bar (no switch)

Pn

Neutral Potential Switch

X

Unused Position on base
Insulating barrier (one side)
Insulating barrier (two sides)

Custom Pole Arrangements: The key may be used to diagram your own
pole arrangement. Be sure to specify base size and whether all C+ line side,
current switch / shunt circuit assemblies are to be bussed together. The
catalog numbers shown above are connected in line-load pairs; therefore, if
bussed is required, different catalog numbers will apply.

Number of Poles

q
	7
q
	10
q
	q Other ____
	4

Test Switch Cover (only available for 10-pole bases)

q Yes | Clear ___ Black ___
	No
q
	

Base Size

q
	10-Pole
q
	7-Pole

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

38

Watthour Meter Forms

WATTHOUR
METER FORMS

Standard Forms | Transformer Rated or Self-Contained

SC

2 and 3-WIRE FORMS
1S & 2S

SC

2 and 3-WIRE FORMS
1S & 2S with BYPASS

TR

2-WIRE FORM 3S
5th Term. 9 o'clock

TR

2-WIRE FORM 3S
with BYPASS

TR

SC

SC

SC

2-WIRE FORM 3S
with BYPASS

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 9 o'clock

2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 9 o'clock

2 ELEMENT
3-WIRE NETWORK
FORM 12S 5th
TERM. 6 o'clock

TR

TR

SC

3-WIRE FORM 4S

3-WIRE FORM 4S
WITH BYPASS

TR

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 5S

TR
2 ELEMENT 2∅3W,
2∅4W, 3∅3W
FORM 5S with
BYPASS

2 or 3 ELEMENT
3∅4W Y or ∆
Y FORM 14S
∆ FORM 15S

SC

2 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S

SC
2 or 3 ELEMENT
3∅4W Y or ∆
FORMS 14S & 15S
with BYPASS

SC

2 or 3 ELEMENT
2∅3W, 2∅4W, 3∅3W
FORM 13S with
BYPASS

TR

2-WIRE FORM 3S
5th Term.6 o'clock

SC
2 ELEMENT 3-WIRE
NETWORK FORM 12S
with BYPASS
5th Term. 6 o'clock

TR
2 ELEMENT
3∅4W Y or ∆
Y FORM 7S
∆ FORM 24S
with BYPASS

TR

2 or 3 ELEMENT
3∅4W Y or ∆
Y FORM 9S
∆ FORM 8S

TR = TRANSFORMER RATED
SC = SELF CONTAINED

TR
2 or 3 ELEMENT
3∅4W Y or ∆
FORMS 8S & 9S
with BYPASS

TR

TR

2 ELEMENT
3∅4W Y
FORM 6S

2 ELEMENT
3∅4W Y
FORM 6S
with BYPASS

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

39

Meter Forms

METER FORMS

Reference Information
DIAGRAM A

1∅2W with 1 P.T. & 1 C.T.
Single Stator Meter(2W1∅) - Form 3S
5T Socket, Test Switch #TS04-0101

DIAGRAM B

1∅3W with 1 C.T.
Single Stator Meter (2W1∅) - Form 3S
5T Socket, Test Switch #TS04-0101
DIAGRAM B

DIAGRAM A

DIAGRAM D

1∅3W or 3W Network with 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

DIAGRAM C

DIAGRAM D

(ALT.LOC.)

(ALT.LOC.)

+
C1

P1 PN

DIAGRAM C

1∅3W with 2 C.T.’s
Single Stator Meter (3W1∅) - Form 4S
6T Socket, Test Switch #TS07-0105

P1 PN

C1

+
C1

C1

+
C1

P1 P2

+
C2

+
C2 C2

+
C1

P1 P2 PN

+
C2 C2

C1

+

P.T. +
+

I
LINE
N

+

LOAD

C.T.

I

+

LINE 2
N

C.T.

+

DIAGRAM E

3∅3W “∆” with 2 P.T.’s & 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

DIAGRAM F

3∅3W “∆” with 2 C.T.’s
2 Stator Meter - Form 5S
8T Socket, Test Switch #TS07-0105

DIAGRAM E

P1 P3

LINE

(BONDED)

(BONDED)

P 2 C+
1

P 2 C+
1

P1 P3

C.T.
C.T. +

LOAD

+

DIAGRAM G

LINE

P1

P 3 P N C+

+

PT

C+ C

+
+

+
C.T.

+

LOAD

+
C.T.

C.T.

+

+
C

C

P3 PN

PT

+ C
C

P1 P2 P3 PN

+ C
C

PT

C.T.

C.T.

+
+

C.T.

(BONDED)

+
+

LOAD
C.T.

C

C+

C

C+

+
+

C.T.

+
+

LOAD
C.T.

C+

C

C+

C

1
2
LINE
3
N(BONDED)

+

+
+

C.T.

+
+

C.T.

+
+

Prewiring: If standard factory prewiring is required,
refer to wiring diagrams on this page. Determine
appropriate diagram and send a copy with order.
If custom factory prewiring is required, specify on
order. Be sure to include meter socket catalog
number, test switch make and catalog number,
meter form number and provide a copy of your
wiring diagram.

C+ C

PT

PT

+

+
1
2
LINE
3
N(BONDED)

+
+

C.T.

+
+

C.T.

+

LOAD

+

C.T.

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

C

+
PT

DIAGRAM J

+ +
+ +

+

+

+

C+

DIAGRAM J

+

1
2
LINE
3
N(BONDED)

1
2
LINE
3
N

LOAD

+

3∅4W “Y” with 3 P.T.’s & 3 C.T.’s
3 Stator Meter - Form 9S
13T Socket, Test Switch #TS10-0109

DIAGRAM I

P1 P2 P3 PN

LOAD

+
C.T.

DIAGRAM I

3∅4W “Y” or “∆” with 3 C.T.’s
“Y” 3 Stator Meter - Form 9S
“∆” 2 Stator Meter - Form 8S
13T Socket, Test Switch #TS10-0109

+

+

1
LINE 2
3

+

C.T.

DIAGRAM H

P1

+

1
LINE 2
3

C.T.

3∅4W “Y” with 2 P.T.’s & 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109

+
PT

+

DIAGRAM H

C+ C

C

+

I
N(BONDED)
2

DIAGRAM G

+
C3 C3

C1

+

3∅4W “Y” with 3 C.T.’s
2 1⁄2 Stator Meter - Form 6S
13T Socket, Test Switch #TS10-0109

DIAGRAM F

+
C3 C3

C1

+

I
N(BONDED)
2

LOAD

LOAD
C.T.

40

Accessories

ACCESSORIES

Hubs and Closing Plates

-RL
Small hub opening

-WL

A7514

-YL

A7515

1 ⁄4" hub

1" hub

-ZL

A7516

-DL

1 ⁄2" hub

1

A7517

2" hub

1

-EL

A7518

2 ⁄2" hub
1

-XL

A7551

Small closing
plate

-R
Large hub opening

-F

A8110
3" hub

-G

A8111

3 ⁄2" hub
1

-H

A8112
4" hub

-X

A9064

Large closing plate

-RRL

S8324

Large hub opening
adapted to small
hub oepning

Notes
• Suffix: Add to catalog number for factory installation of hub.
• Packaging: Individually packed units for field installation.
• Abbreviations: H.O. (hub opening), C.P. (closing plate).

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

41

Accessories
Closing Covers, Sealing Rings and Touch-Up Paint
Sealing Rings

Closing Covers

Meter Closing Plate
(Ring Type / Ringless)

Metal Closing Plate
(For Ringless Sockets)

6003 - Grey Plastic

CP-21

MR-2 - Snap Action
MR2-SS - Stainless
Steel

MR-4 - Screw Type
(Stainless Steel)

6116 - Clear Plastic

Touch-Up Paint

A-GP - Light Grey

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

ACCESORIES

42

Energization of Electrical Equipment

ENERGIZATION
OF ELECTRICAL
EQUIPMENT

Important Information for Installers

Important Note
In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving
utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment.

Before Energizing
A. Give equipment a thorough visual examination to determine that:
		
1) No shipping or installation damage exists.
		
2) Proper clearances have been maintained.
		
3) All connections have been made.
		
4) Equipment is clean and dry.
B. Make a thorough examination to:
		
1) Verify tightness of all bolted connections (see table below).
		
2) Manually operate all circuit breakers, switches, relays, etc.
		
3) Check rigidity of all mountings, bus bars and components.
		
4) Use test equipment to check continuity of circuitry and integrity of insulation.
C. All switches and circuit breakers should be in the “off” position.
D. Verify that manual meter bypass (if applicable) is in non-bypass position.
E. Install cover and/or close doors.
F. If installation is not being energized at this time, follow “after-energizing” steps listed below. These steps will secure the installation in
	 case of accidental energization.

When Energizing
A. Use caution and follow established safety procedures:
	 1) Wear safety apparel.
	 2) Use safety equipment.
	 3) Take action to prevent injury to yourself and others in the event of failure of the installation.
	 4) Take action to prevent/decrease damage to property in the event of failure of the installation.
	 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it.

After Energizing
A. Secure the installation:
	 1) To prevent accidental contact with energized parts, cover all openings with approved filler devices.
	 2) To prevent unauthorized access, secure all covers and/or doors with approved security devices.
	 3) Attach/post information to advise others of potential hazards associated with the installation.

Recommended Torque for General Applications*
Joint Description

Nominal
Size

Screw

Nut

Head Type

Torque
(Inch Lbs.)
20-25 inch lbs.

10

Brass

Brass Nut or Extruded Hole

All

10

Steel

Copper or Aluminum Busbar ≤ 1/8"

All

25-30 inch lbs.

10

Steel

Steel Nut or Extruded Hole; CU or AL Busbar > 1/8"

All

30-35 inch lbs.

12

Steel

Aluminum Extruded Hole

All

30-35 inch lbs.

12

Steel

Steel Nut or Extruded Hole

All

40-50 inch lbs.

1/4

Steel

Aluminum Extruded Hole

All

40-50 inch lbs.

1/4

Steel

Steel Nut or Extruded Hole; CU or AL Busbar

All

50-60 inch lbs.

5/16

Steel

Aluminum Extruded Hole

Hex

60-70 inch lbs.

5/16

Steel

Steel Nut or Extruded Hole; CU or AL Busbar

Hex

100-150 inch lbs.

3/8

Steel

Steel Nut

Hex

150-200 inch lbs.

1/2

Steel

Steel Nut

Hex

200-250 inch lbs.

* Interior labels
typically indicate
the required
torque for wire
connectors and
studs, and should
be referenced first.
CU: Copper
AL: Aluminum

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Materials & Finishes
Reference Information

43

MATERIALS
& FINISHES

Materials
Steel Quality
The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing.
*American Iron and Steel Institute.

Steel Sheet
16 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated. (AISI G90)
14 gauge, galvanized, sheet: 1 1/4 oz./ sq.ft. class zinc-coated.

Aluminum Extrusion
Wire-Terminals: Alloy; 6061-T6, Tin-plated for CU/AL wire.
Bus Bar: Alloy; 6101-O & 6063-O

Aluminum Sheet
3000 series aluminum sheet, H14, or 5052 series aluminum sheet, H32. Where applicable thicknesses range from .064–.125

Copper Sheet & Bus
Electrolytic copper with tin plating in most applications.

Insulating Materials
• 	In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant,
thermoset polyester molding compounds.
• 	Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds.
• 	Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component
parts and barriers.

Finish
Process
Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the
chemical analysis of the weather resistant finish, please contact the factory.

Metal Fastners
Zinc-coated with a chromate dip.

Ratings & Compliance
Ratings & Compliance
All Milbank electrical enclosures in this catalog are rated “Type 3R Enclosure” unless specified otherwise on the product’s page. All
enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code.
UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 414, File E30202), Test Switches (UL 414, File
E62531), Power Outlets (UL 231, File E90945), Panelboards (UL 67, File E32628) and Pullout Switches (UL 1429, File E133062). Additional
standards are utilized as applicable: Meter Sockets (ANSI C12.7), Test Switches (ANSI C12.9) and Panelboards (NEMA PB-1).

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

44

Index

INDEX

6003....................................................41
6116....................................................41
243210-LC3R-SP..................................18
303610-CT3R.......................................19
303610-LC3R-SP..................................18
323610-LC3R-SP..................................18
363010-CT3R.......................................19
363016-CT3R.......................................19
363610-CT3R.......................................19
363612-CT3R.......................................19
363612-LC3R-SP..................................18
363616-CT3R.......................................19
423616-CT3R.......................................18
443010-CT3R.......................................19
483612-CT3R.......................................19
483616-CT3R.......................................19
484812-CT3R.......................................19
606013-CT3R.......................................19
A6014-O-400-NKO.............................28
A6015-O-400-NKO.............................28
A7514..................................................40
A7515..................................................40
A7516..................................................40
A7517..................................................40
A7518..................................................40
A7551..................................................40
A8110..................................................40
A8111..................................................40
A8112..................................................40
A9064..................................................40
CP-21...................................................41
CT203611-HC......................................20
CT242411-SC......................................20
CT243011-HC......................................20
CT243011-SC......................................20
CT24329-SC........................................20
CT243611-HC......................................20
CT243611-SC......................................20
CT244811-HC......................................20
CT244811-SC......................................20
CT303011-SC......................................20
CT303611-HC......................................20
CT303611-SC......................................20
CT303614-SC......................................20
CT304811-HC......................................20
CT363611-HC......................................20
CT363611-SC......................................20
CT364211-SC......................................20

CT364811-HC......................................20
CT364811-SC......................................20
CT364814-HC......................................20
CT364814-SC......................................20
CT424211-SC......................................20
CT484811-HC......................................20
CT484811-SC......................................20
CT484814-HC......................................20
K4722..................................................21
K4729..................................................21
K4793..................................................21
K4794..................................................21
K4795..................................................21
K4796..................................................21
K4797..................................................21
K4797..................................................21
K4798..................................................21
K4798..................................................21
K4903..................................................21
K4904..................................................21
K5747..................................................21
K5752..................................................21
K5930..................................................21
K5931..................................................21
K5932..................................................21
K5933..................................................21
MR-2....................................................41
MR2-SS................................................41
MR-4....................................................41
PT48AL................................................18
PT48AR................................................18
PT48L...................................................18
PT48R..................................................18
S1855-O..............................................22
S1856-O..............................................22
S1891-XT.............................................27
S1891-XT.............................................27
S1891-XT.............................................27
S2674-XT.............................................27
S2690-XT.............................................27
S2777-4X.............................................28
S2811-4X.............................................28
S3831-XT.............................................27
S4084-O..............................................31
S8324..................................................40
S9573-X...............................................27
SC6010-O-BL-21.................................10
SC6011-O-BL-21.................................10

TS04-0101...........................................36
TS04-0104...........................................36
TS07-0049...........................................36
TS07-0105...........................................36
TS07-0106...........................................36
TS10-0016...........................................36
TS10-0109...........................................36
TS10-0110...........................................36
TS10-0111...........................................36
TS10-0112...........................................36
U2161-XT.............................................29
U2228-XT.............................................29
U2229-XT.............................................29
U3320-R...............................................24
U3322-R...............................................24
U3340-O..............................................24
U3342-O..............................................24
U3555-R...............................................24
U3565-O..............................................24
U4163-XT-11-LI....................................30
U4166-XT-Z21-LI..................................30
U4468-XT.............................................23
U4468-XT-K4469..................................23
U4490-XL.............................................11
U4492-XL.............................................11
U4493-XL.............................................11
U4494-XL.............................................12
U4496-XL.............................................12
U4497-XL.............................................12
U4523-X-Z11-LI...................................30
U4554-X-Z21-LI...................................30
U4811-O-21.........................................13
U5944-XT.............................................29
U5990-O..............................................23
UC1290-XL............................................5
UC1291-RL............................................5
UC1299-XL............................................5
UC1300-RL............................................5
UC3423-XL............................................8
UC3425-XL............................................8
UC3426-XL............................................8
UC3428-XL............................................8
UC3433-XL............................................8
UC3434-XL............................................8
UC3435-XL............................................8
UC3436-XL............................................8
UC3438-XL............................................8
UC3443-XL..........................................10

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

45

Index
UC3444-XL..........................................10
UC3448-XL..........................................10
UC3453-XL..........................................10
UC3458-XL..........................................10
UC7233-XL............................................5
UC7235-XL............................................5
UC7237-XL............................................5
UC7442-RL............................................6
UC7444-RL............................................6

INDEX

UC7445-RL............................................6
UC7446-RL............................................7
UC7448-RL............................................7
UC7449-RL............................................7
UC7449-XL-871.....................................9
UC7450-RL............................................7
UC7460-RL............................................7
UC7461-RL............................................7
UC7478-RL............................................6

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

UC7532-RL............................................7
UC7544-RL............................................5
UC7545-RL............................................5
UC7582-XL............................................5
UC7636-RL............................................7
UCSS3423-O.......................................14
UCSS3433-O.......................................14

46
NOTES

Notes

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Notes

Utility requirements for this equipment may vary. Always consult the serving
utility for their requirements before ordering or installing equipment.
Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

47
NOTES

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

INSTRUMENT 4/13



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.5-c021 79.154911, 2013/10/29-11:47:16
Create Date                     : 2014:04:22 10:42:16-05:00
Metadata Date                   : 2014:04:22 10:42:58-05:00
Modify Date                     : 2014:04:22 10:42:58-05:00
Creator Tool                    : Adobe InDesign CC (Windows)
Instance ID                     : uuid:35154251-de7f-471f-ba12-a9c9454b1171
Original Document ID            : xmp.did:860755593A03E2118F05AE0EA9CB0C4F
Document ID                     : xmp.id:c9c1fa68-987f-a44b-9a5c-ed9e5271dac6
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:b06e9c3d-b454-8249-8605-06a0e89924ad
Derived From Document ID        : xmp.did:A6CB44A428A2E211A442813AF789406F
Derived From Original Document ID: xmp.did:860755593A03E2118F05AE0EA9CB0C4F
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC (Windows)
History Changed                 : /
History When                    : 2014:04:22 10:42:16-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 48
Creator                         : Adobe InDesign CC (Windows)
EXIF Metadata provided by EXIF.tools