1274458_6003_ENG_S_W 113782 Catalog
2014-07-05
: Pdf 113782-Catalog 113782-Catalog 095969 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 65
Download | |
Open PDF In Browser | View PDF |
Test Tools Catalog Volume 41, 2011 Keeping your world up and running. What’s new Fluke 381 Remote Display Clamp Meter with iFlex™ Part of Fluke’s new family of clamp meters, the Fluke 381 Clamp Meter combines iFlex flexibility with remote reading capability—the best of both worlds. • Remote display reads measurements up to 30 feet away • Measure up to 2500 A ac with the iFlex flexible current probe • 1000 A ac and dc current measurement with fixed jaw • 1000 V ac and dc voltage measurement • Min/Max/Avg and inrush recording • CAT IV 600 V, CAT III 1000 V Remote display and iFlex For information on the new 381 Remote Display Clamp Meter with iFlex™ see page 4. Fluke 810 Vibration Tester Powerful vibration testing The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. • Utilizes a simple step-by-step process to report on machine faults, without needing prior measurement history • On-board identification and location of most common mechanical faults: bearings, misalignment, unbalance, looseness • 2 GB expandable on-board memory • Four-level fault severity scale • Tri-axial accelerometer reduces measurement time by 2/3 over single axis accelerometers For information on the new 810 Vibration Tester see page 52. 1555 Insulation Resistance Tester Ranges up to 10 kV From motors and generators to cables and switchgear, Fluke now takes you all the way to 10 kV. • Ideal for testing a wide range of high voltage equipment • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup • Long battery life allows for over 750 tests between charges • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined label for easy recall For information on the new 1555 Insulation Resistance Tester see page 25. TiS Building Diagnostic Thermal Imaging Scanner Finally! An entry level thermal imager for quick, easy and accurate problem identification and troubleshooting, designed specifically for the building inspection professional. • Most affordable thermal imager on the market that meets proposed RESNET infrared inspection standard • 120 x 120 resolution • Large, 3.7 inch display–30 percent larger than comparable imagers • Rugged body withstands 2 m (6.5 ft) drop test • Award winning ergonomic design For information on the new TiS Thermal Imager see page 47. Display 30 % larger 2AC VoltAlert™ Voltage Tester Battery check button 2AC is the latest addition to the VoltAlert™ ac noncontact voltage tester family from Fluke, and is designed to be pocket-sized and easy to use. The 2AC tests for energized circuits and defective grounds. The tip of the pocket-sized tester will glow red if voltage is present. • Voltage detection from 90 V ac to 1000 V ac • Always on, using special low power circuitry to sustain battery life and ensure your 2AC is always ready • Innovative ‘Battery Check’ button function ensures battery is in good condition • CAT IV 1000 V overvoltage rated product for best in class user protection For information on the new 2AC VoltAlert see page 21. 190 Series II ScopeMeter ® Portable Oscilloscopes Multiply your diagnostic powers with the first CAT III 1000 V/CAT IV 600 V rated, four-channel portable scope on the market. The new Fluke 190 Series II brings an unprecedented combination of performance and ruggedness into the field. • Fast sample rate: up to 2.5 GS/s with up to 400 ps resolution • Deep memory: 10,000 point per trace waveform capture • Single shot, pulse width and video triggering • Seven-hour, high-performance Li-ion battery is standard • Two isolated USB ports for memory devices and PC connectivity For information on the new 190 Series II ScopeMeter see page 42. 4 channel testing Test Tools Catalog Volume 41, 2011 Contents Fluke Corporation is the world leader in compact, professional electronic test tools. From industrial maintenance to commercial building operations, Fluke tools deliver the testing and troubleshooting capabilities to keep global commerce and industry up and running. Fluke customers are technicians, engineers, electricians, and building diagnostics professionals— people who stake their reputations on their tools. 4 8 Clamp Meters Digital Multimeters 18 19 21 Distance Meters Earth Ground Testers Electrical Testers 22 24 26 Indoor Air Quality Tools Insulation Resistance Testers Power Quality Analyzers 31 40 44 Process Calibration Tools ScopeMeter® Thermal Imaging Tools Test Tools 49 51 52 53 Thermometers IR-Windows Vibration Tester Accessories www.fluke.com 3 Fluke 381 Remote Display True-rms AC/DC Clamp Meter with iFlex x™ All the bells and whistles The Fluke 381 Clamp Meter combines iFlex flexibility with remote reading capability for the ultimate in innovation and safety. • Remote display reads measurements up to 30 feet away • iFlex flexible current probe included, 18-inch circumference • 2500 A ac current measurement with iFlex • 1000 A ac and dc curret measurement with fixed jaw • 1000 V ac and dc voltage measurement • Frequency measurement to 500 Hz • 60 kΩ resistance measurement • Min/Max/Avg and inrush recording • CAT IV 600 V, CAT III 1000 V • Three-year warranty See specifications chart on page 7. Mobile resources Fluke clamp meters are going mobile. Visit m.fluke.com from any smartphone for on-the-go tips, videos and info regarding our newest clamp meters. Join the conversation! We’ve created interactive messaging boards dedicated to discussing all things clamp meter. Give us a shout, start a discussion or participate in a poll— we’re eager to hear your thoughts. Visit www.fluke.com/ readyforanything True RMS Fluke 365 Detachable Jaw True-rms AC/DC Clamp Meter Where rugged meets reliable The Fluke 365 Clamp Meter offers a small, detachable jaw—with four feet of coil—that makes it easy to take and read measurements in tight or hard-to-reach places. • 200 A ac and dc current measurement • 600 V ac and dc voltage measurement • 6000 Ω resistance measurement • Built-in flashlight • Large, easy-to-read backlight display • Three-year warranty 3D virtual demos Want to see the Fluke 376 and Fluke 381 Clamp Meters up close and personal? Visit www.fluke.com/ clampfamily for links to two 3D virtual demos. Recommended accessories See specifications chart on page 7. TL223 TL71 SureGrip™ Electrical Test Lead Set See page 57 Premium Test Lead Set See page 57 True RMS Ordering information Included accessories Models 18-inch iFlex™ Flexible Current Probe, test leads, soft carrying case, instruction card, safety information sheet, five AA alkaline batteries. FLUKE-381 Test leads, soft carrying case, instruction card, safety information sheet, five AA alkaline batteries. FLUKE-365 Remote Display True-rms AC/DC Clamp Meter with iFlex™ i2500-10 i2500-18 10 inch iFlex™ Flexible Current Probe See page 5 18 inch iFlex™ Flexible Current Probe See page 5 Detachable Jaw True-rms AC/DC Clamp Meter Check price and availability at www.fluke.com/wtb-clamps 4 Clamp Meters For more information, go to www.fluke.com/clamps Fluke 370 Series Clamp Meters Be ready for anything Our new family of true-rms clamp meters provides a range of state of-the-art feaures to meet even the most demanding ob requirements. All four of the new clamp meters have mproved base features such as a large, backlit display, true-rms standard, CAT IV afety rating and a durably constructed body. Additionally, the 376, 375 and 374 are compatible with the iFlex flexible urrent probe (included with the 376, old separately for the 375 and 374), and provide increased measurement readings o 1000 A and 1000 V ac and dc. iFlex™ Flexible Current Probe See specifications chart on page 7 for details per model. ke uke 373 Unprecedented measurement flexibility. The new iFlex flexible current probe expands the measurement range of select Fluke clamp meters to 2500 A ac while providing increased display flexibility, improved wire access and the ability to measure awkward-sized conductors. Available in 18-inch and 10-inch coil sizes. Visit www.fluke.com/ iFlex-18 for additional specs. True RMS Quick reference guide conversion table Old model New model Fluke 337 Fluke 376 Fluke 336 Fluke 375 Fluke 374 Fluke 335 Fluke 334 Fluke 333 Fluke 374 Feature changes Includes all 337 features plus: • CAT IV 600 V, CAT III 1000 V • iFlex 2500 A ac • 1000 V ac/dc • mV dc • 60 kΩ • 1000 µF Includes all 336 features plus: • CAT IV 600 V, CAT III 1000 V • Optional iFlex 2500 A ac • mV dc • 60 kΩ • 1000 µF • Min/Max/Avg Includes all 336 features (except low pass filter) plus: • CAT IV 600 V, CAT III 1000 V • 1000 µF • Optional iFlex 2500 A ac • Min/Max/Avg Includes all 335 features plus: • CAT IV 600 V, CAT III 1000 V • Optional iFlex 2500 A ac • Min/Max/Avg • 600 A ac/dc • 1000 µF Fluke 373 Includes all 335 features (except inrush) plus: • CAT IV 300 V, CAT III 600 V • 1000 µF Fluke 374 Includes all 334 features plus: • CAT IV 600 V, CAT III 1000 V • Optional iFlex 2500 A ac • True-rms • 600 A ac/dc Fluke 373 Includes all 334 features (except inrush) plus: • CAT IV 300 V, CAT III 600 V • True-rms Fluke 373 Includes all 333 features plus: • CAT IV 300 V, CAT III 600 V • True-rms • 600 A ac • 6000 Ω Ordering information Included accessories Models 18-inch iFlex™ flexible current probe, test leads, soft carrying case, instruction card, safety information sheet, two AA alkaline batteries. FLUKE-376 True-rms AC/DC Clamp Meter with iFlex™ Test leads, soft carrying case, instruction card, safety information sheet, two AA alkaline batteries. FLUKE-375 True-rms AC/DC Clamp Meter Test leads, soft carrying case, instruction card, safety information sheet, two AA alkaline batteries. FLUKE-374 True-rms AC/DC Clamp Meter Test leads, soft carrying case, instruction card, safety information sheet, two AA alkaline batteries. FLUKE-373 True-rms AC Clamp Meter For more information, go to www.fluke.com/clamps Recommended accessories TL223 TL71 SureGrip™ Electrical Test Lead Set See page 57 Premium Test Lead Set See page 57 • 1000 µF • Min/Max/Avg • 1000 µF • 1000 µF i2500-10 i2500 18 10 inch iFlex™ Flexible Current Probe See page 5 18 inch iFlex™ Flexible Current Probe See page 5 AC285 TL175 SureGrip™ Alligator Clips See page 57 TwistGuard™ Test Leads See page 57 Check price and availability at www.fluke.com/wtb-clamps Clamp Meters 5 Fluke 320 Series Clamp Meters Get more done The Fluke 321 and 322 are designed to verify the presence of load current, ac voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable environments. • Precised measurements with 1.8 % basic accuracy • Resolution up to 0.01 A and 0.1 V • Measures ac current 40.00 A/400.0 A • Measures ac and dc volts to 600 V • Resistance measurement to 400 Ω • Continuity for quick checking of shorts See specifications chart on page 7 for details per model. Fluke 322 Fluke 321 Fluke 902 True-rms HVAC Clamp Meter Application note DMM vs. Clamp Meter What you know about digital multimeters and clamp meters can make a big difference to your bottom line. How well you equip yourself to do your work plays a big role in your success. When it comes to electrical test equipment, are you sure you have the right tools for the job? Determine the answer to that question by assessing your measuring needs, and learning a few things about DMMs and clamp meters—read the DMM vs. Clamp Meter application note today. Download this application note at www.fluke.com/DMMvsClamp Recommended accessories Just for our HVAC pros HVAC (heating, ventilation, air conditioning) technicians require a service tool that can consistently keep up with their demands. The Fluke 902 expands the existing line of quality Fluke clamp meters by delivering the features necessary to diagnose and repair HVAC systems. Combined with true-rms technology and a CAT III 600 V rating, the Fluke 902 helps technicians do their jobs safely and accurately. • Designed for HVAC applications with capacitance, dc current (µA), and temperature measurements • Small body and jaws fit perfectly in your hand and into tight places • Handy “Display Hold” button keeps measurements on the display • Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch) • Three-year warranty TL223 TL71 SureGrip™ Electrical Test Lead Set See page 53 Premium Test Lead Set See page 54 LVD2 H3 Volt Light See page 56 Clamp Meter Holster See page 62 See specifications chart on page 7. True RMS Ordering information 6 Included accessories Models Test leads, soft carrying case, instruction card, safety information sheet, two AA alkaline batteries. FLUKE-321 FLUKE-322 Clamp Meter Clamp Meter Test leads, temperature probe, soft carrying case, users manual, two AA alkaline batteries. FLUKE-902 True-rms HVAC Clamp Meter Soft carrying case, instruction card, safety information sheet, five AA alkaline batteries. FLUKE-353 AC/DC True-rms Clamp Meter, 2000 A, amps only 1.5 m silicone rubber test leads, test probes, alligator clips, soft carrying case, six AA batteries, users manual. FLUKE-355 AC/DC True-rms Clamp Meter, 2000 A Clamp Meters Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/clamps Fluke 353/355 AC/DC True-rms Clamp Meters, 2000 A Versatile, professional, accurate Application note Confidently take reliable readings with the true-rms Fluke 355 and 353 clamp meters—the tools of choice for high current clamp-on amp meter measurement up to 2000 A. • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc • Large 58 mm (2.3 in) jaw • In-rush current measurement • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc (355 only) • Resistance to 400 KΩ (355 only) • Continuity beeper (355 only) • Frequency measurement to 1 KHz • Selectable low pass filter mode • Min/Max/Avg • Large display with backlight Clamp Meter ABCs What is a clamp meter and what can it do? What measurements can be made with a clamp meter? How do you get the most out of a clamp meter? Which clamp meter is best suited to the environment the meter will be used in? The answers to these questions can be found in this application note. Ordering information on page 6. True RMS Download this application note at www.fluke.com/ClampABCs Specifications – Clamp meters Residential/commercial electrical General purpose Industrial electrical HVAC/R High end industrial, utility iFlex accessory Leakage 360 • 321 322 365 373 374 375 376 381 902 353 355 i2500-10/ i2500-18 AC current • • • • • • • • • • • • AC voltage • • • • • • • • • • Resistance • • • • • • • • • • Continuity • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • DC volts DC current • True-rms • • Frequency • • AC + DC voltage AC + DC current • Min/Max/Avg • • • • • • • • • • • Temperature • Capacitance • • • • • • • • • • • • • • • • Special features Inrush current mode Low pass filter 18-inch iFlex Flexible Current Probe Optional Optional Included Included 10-inch iFlex Flexible Current Probe Optional Optional Optional Optional • Remote display • Flashlight/torch • Display Display hold • • Backlight • • • • • • • • • • • • • • • • • • 1.3 in • Specifications Jaw opening Max wire size Current range ac rms Accuracy ac current (50/60 Hz) AC Response 1 in 0.7 in 500 MCM 17 mm (0.67 in) 0 to 400.0 A 0 to 200.0 A Averaging True-rms Accuracy dc current 2% ± 5 counts Voltage range ac True-rms True-rms 0 to 999.9 A True-rms 0 to 600.0 A 1.2 % ± 5 counts 2%±5 counts True-rms 0 to 1000 V 0 to 400 1 2%±5 counts 0 to 600.0 A True-rms Frequency measurement range For more information, go to www.fluke.com/clamps 1.5 in 1250 MCM 0 to 1400 A 0 to 2500 A 0 to 60 A 1.5 % ± 5 counts 3% ± 5 counts 1% ± 5 counts True-rms Averaging True-rms True-rms 0 to 200 µA 0 to 2000 A 1% ± 5 counts 1.5 % ± 5 counts 0 to 600.0 V 1%±5 counts 1%±5 counts 0 to 1000 V 0 to 600.0 V 0 to 1000 V 0 to 60 k1 0 to 9999 1 0 to 400 K1 1%±5 counts 1 % ± 5 counts 0 to 6000 1 5.7 in/3.2 in 600.0 V 1.5 % ± 5 counts 0 to 600.0 V 1%±5 counts True-rms 0 to 999.9 A 2 % ± 5 counts 1%±5 counts 2.3 in 750 MCM or three 500 MCM 0 to 600.0 V Voltage range dc Resistance range 1.2 in 2 % ± 5 counts 0 to 200 A Accuracy dc voltage 0 to 600.0 A 1.8 % ± 5 counts Current range dc Accuracy ac voltage 1.3 in 750 MCM 500 Hz 5 to 1000 Hz 500 Hz Clamp Meters 7 Pick the right digital multimeter for you Digital multimeter selection guide Models Highest accuracy 289 Industrial troubleshooting 87V Built-in thermometer 179 Building maintenance 117 HVAC/R technicians 116 Remote Display 233 Insulation Multimeter 1587 IP 67 Industrial 28 II Best for Data logging Variable speed drives Every day use Wide variety of electrical work HVAC troubleshooting Perform two-man jobs alone Troubleshooting and preventive maintenance Harsh environments Basic features True-rms readings AC+DC AC AC AC AC AC AC AC Basic dc accuracy 0.025 % 0.05 % 0.09 % 0.5 % 0.5 % 0.25 % 0.09 % 0.05 % Wide bandwidth 100 kHz 20 kHz • • • • • • • Digits 4-1⁄2 4-1⁄2 3-1⁄2 3-1⁄2 3-1⁄2 3-1⁄2 Counts 50000 20000 6000 6000 6000 6000 Voltage ac/dc 1000 V 1000 V 1000 V 600 V 600 V Current ac/dc 10 A 10 A 10 A 10 A 600 µA 500 M1 50 M1 50 M1 40 M1 Frequency 1 MHz 200 kHz 100 kHz Capacitance 100 mF 10 mF 10 mF Temperature +1350 °C +1090 °C +400 °C Auto/manual ranging 20 kHz • 4-1⁄2 6000 20000 1000 V 1000 V 1000 V 10 A 400 mA 10 A 40 M1 40 M1 50 M1 50 M1 50 kHz 50 kHz 50 kHz 100 kHz 200 kHz 10 mF 10 mF 10 mF 10 mF 10 mF +400 °C +400 °C +500 °C +1090 °C Measurements Resistance dB 60 dB Conductance 50 nS 60 nS Duty cycle/pulse width • •⁄– 60 nS Motor drive measurements/low pass filter • • Continuity with beeper/ diode test • • • • • Low ohms (50 1) • •⁄– • • • • • • • Display Dual display • Analog bargraph • • • • • Backlight • • • • • • • • Remote display Data storage and exchange Time stamp • 250 µs 250 µs Display Hold/Auto (Touch) Hold • • Relative reference • • PC interface • Min/Max recording Fast Min/Max • • • • • • 250 µs • • • • • • • Data logging Readings memories 10,000 Other features • Automatic selection, LoZ • • Insulation test range 0.01 M1 to 2 G1 Non-contact ac voltage detector • Real-time clock • Overmolded case, integrated holster • • • Removable holster • • • • ToolPak compatibility • • • • • • Closed case calibration/ separate battery door • • • • • • • Automatic power off • • • • • • • Low battery indication • • • • • • • Operating temperature ranges –20 °C, +55 °C –20 °C, +55 °C –10 °C, +50 °C –10 °C, +50 °C –10 °C, +50 °C –10 °C, +50 °C IP 42 IP 30 IP 42 IP 42 Warranty Limited lifetime Limited lifetime Three-years Three-years Input alert • • • • Completely sealed/ watertight • • IP rating • • –40 °C, +55 °C IP 30 IP 67 Three-years Limited lifetime Warranty and electrical safety Dangerous voltage indication Three-years • • • • • • • • • CAT III measurements 1000 V 1000 V 1000 V 600 V 600 V 1000 V 1000 V 1000 V CAT IV measurements 600 V 600 V 600 V 600 V 600 V 600 V 11 12 13 14 15 9 17 10 See page 8 Limited lifetime Digital Multimeters For more information, go to www.fluke.com/dmm Fluke 233 Remote Display Digital Multimeter The Fluke 233 Remote Display Digital Multimeter allows you to be in two places at once. The removable display solves several problems. First, you no longer have to hold both the meter and the test leads to make a measurement. Second, making measurements in hard-to-reach places is much easier, and third, it allows you to take measurements in machines or panels that are physically separated from a limit switch or an isolator switch. The Fluke 233 is also designed to work in areas where the operator can’t be close to the active measurement point, like clean rooms or hazardous areas. • Wireless technology allows the display to be carried up to 30 feet away from the point of measurement for added flexibility • The removable magnetic display can be conveniently mounted where it is easily seen • Low-power 802.15.4 wireless technology does not interfere with measurement accuracy • Use as a conventional multimeter when the display is connected • True-rms ac voltage and current • Built-in thermometer • Auto power off maximizes battery life (400 hours) • Radio transmitter automatically turns off when the display is connected to the meter • Record signal fluctuations using the Min/Max function True RMS Made in the U.S.A. of U.S. and non U.S. parts Features Recommended Product video accessories View this product demonstration to learn more about the Fluke 233. www.fluke.com/233video Application note The new Fluke 233 wireless digital multimeter What if, as an electrical professional, you could take a clampon ammeter reading using your digital Recommended multimeter (DMM) with the disconnect door or MCC cubicle door closed? kits Download this application note at www.fluke.com/233dmm Features Measure up to 1000 V ac and dc Measure up to 10 A (20 A for 30 seconds) 10,000 μF capacitance range Frequency to 50 kHz Recommended accessories Resistance, continuity and diode test Min/Max and average recording to capture variations automatically Three-year warranty Specifications Functions Specifications DC voltage Range Accuracy 0.25 % + 2 AC voltage Range 0.1 mV to 1000 V Accuracy 1.0 % + 3 DC current Range 0.1 mA to 10 A Accuracy 1.0 % + 3 AC current Range 0.1 mA to 10 A Accuracy 1.5 % + 3 Resistance Range 0.1 Ω to 40 MΩ 0.1 mV to 1000 V Capacitance 1000 nF to 9999 µF Frequency 0.1 Hz to 50.00 kHz Temperature -40 °C to +400 °C (-40 °F to 752 °F) Power Three AA batteries main body, two AA batteries display module Battery life 400 hours Compliance CAT IV 600 V , CAT III 1000 V Size (HxWxL) 5.3 cm x 5.3 cm x 19.3 cm (2.08 in x 2.08 in x 7.6 in) Weight 604 g (1.3 Ib) TPAK TL220 Magnetic Meter Hanger See page 62 SureGrip Industrial Test Lead Set See page 53 80PK-9 i400s General Purpose Probe See page 58 AC Current Clamp See page 60 80AK-A C35 Thermocouple Adapter See page 59 Soft Carrying Case See page 54 Ordering information Included accessories Models Test leads, temperature probe, alligator clips, batteries, users manual. FLUKE-233 Remote Display Multimeter Check price and availability at www.fluke.com/wtb Digital Multimeters 9 Fluke 27 II/28 II Industrial Digital Multimeters The 27 II and 28 II Digital Multimeters are designed for tough work environments. Both meters have IP 67 waterproof and dustproof rating. They both have an extended operating temperature range of -15 °C to + 55 °C (5 °F to 131 °F) and 95 % humidity. • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (28 II) • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (28 II) • Hi-resolution 20,000 count display mode (28 II) • Resistance and continuity. Relative mode to remove test lead resistance from low ohms measurements • Large digit display with bright, two-level backlight • Backlit keypad buttons allow for easy visibility in low-lit areas • Optional magnetic hanger for easy setup and viewing freeing your hands for other tasks • U.S. Mine Safety and Health Administration (MSHA) approved United States Department of Labor Made in the U.S.A. of U.S. and non U.S. parts True RMS MSHA Mine Safety and Health Administration Features Features Tested to withstand a 3 m (10 ft) drop Product video How dirty does your DMM get? Watch the video below to see more. www.fluke.com/dirtydmm Application note Tough places, tough tools Out on the job site, concrete finishers stand ready to shape wet ready-mix into a new stretch of highway. Mixer trucks are lined up at the concrete batch plant, waiting to take on their loads. But hold on—an electrical problem has shut down the plant. It’s time to call Keithly Electric. Wide 1000 V measurement range Download this application note at www.fluke.com/toughdmms True-rms ac voltage and current for accurate measurements on non-linear signals (28 II) Average responding voltage and current measurements (27 II) 10 A continuous (20 A for 30 seconds) Frequency and capacitance Recommended accessories Record signal fluctuations using the Min/Max function Specifications Specification DC voltage 27 II 28 II Range 0.1 mV to 1000 V Accuracy AC voltage Range DC current Range AC current Range Resistance Range 0.05 % +1 0.05 % + 1 0.1 mV to 1000 V Accuracy 0.5 % +3 0.7 % +4 0.2 % + 4 0.2 % + 4 0.1 µA to 10 A Accuracy 1.5 % + 2 1.0 % + 2 0.1 Ω to 50 MΩ Display counts 6000 Capacitance 6000 / 19,999 1 nF to 9999 µF Frequency 0.5 Hz to 199.99 kHz Temperature -200 °C to +1090 °C Low pass filter (measurement on VSD’s) PV350 i410 Pressure-Vacuum Module See page 63 AC/DC Current Clamp See page 60 Yes Compliance CAT IV 600 V , CAT III 1000 V Measurement method Avg. responding Power True-rms Three AA batteries Battery life 800 hours Dimensions (DxWxH) 2.5 in x 3.93 in x 7.8 in Weight with holster 698.5 g (1.54 lb) Ordering information Included accessories Models Test leads, temperature probe, alligator clips, batteries, holster, users manual. FLUKE-27-II Industrial Multimeter FLUKE-28-II Industrial Multimeter Digital Multimeters TLK-225 SureGrip Master Accessory Set See page 55 0.1 µA to 10 A Accuracy 10 TPAK Magnetic Meter Hanger See page 62 CXT80 C550 Extreme Hard Case See page 54 Tool Bag See page 54 Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/dmm Fluke 289 and 287 True-rms Logging Multimeters Find little problems before they become big ones. The Fluke 289 and 287 are the next generation in high performance industrial logging multimeters. • Large 50,000 count, 1/4 VGA dot matrix display with white backlight • Logging function with expanded memor for unattended monito of signals over time. Using TrendCapture displays V dc logged data. on-board TrendCapture, users can graphically review logged readings without needing a PC. Store up to 10,000 recorded events • Save, name, and recall multiple logging sessions before PC download is necessary • Zoom on trend, provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times • Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current. Useful for measuring and comparing differences in motor winding resistance or contact resistance (289) • Low pass filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (289) • LoZ volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power (289) True RMS Recommended accessories TLK289 TLK287 Industrial Test Lead Set See page 55 Electronic Test Lead Set See page 55 TPAK i410 Magnetic Meter Hanger See page 62 AC/DC Current Clamp See page 61 FVF-SC2 C280 FlukeView Forms See page 63 Soft Case See page 54 Recommended kits Made in the U.S.A. of U.S. and non U.S. parts Features Features Multiple on screen displays Yes True-rms ac bandwidth 100 kHz dBV/dBm Yes DC mV resolution 1 µV Megohm range up to 500 M1 Conductance 50.00 nS Continuity beeper Yes Elapse time clock/time of day clock Yes Min/Max/Avg/duty cycle/pulse width Yes Isolated optical DMM interface with USB PC connection Yes Auto/touch hold Yes Over 200 hours logging capacity with new power saving function Warranty Yes 289/FVF kit includes: • True-rms industrial logging multimeter with TrendCapture • FlukeView Forms Software and cable • Temperature probe • Silicone test lead set • Alligator clips • Meter hanging accessory • Soft case Limited lifetime Specifications Functions Range and resolution AC volts or dc volts 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V Basic Accuracy AC current dc current 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A Temperature (excluding probe) -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) 1.0 % Resistance 50.000 1, 500.00 1, 5.0000 k1, 50.000 k1, 500.00 k1, 5.0000 M1, 50.00 M1, 500.0 M1 0.05 % Capacitance 1.000 nF,10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100 mF 1.0 % Frequency 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz .005 % 0.025 % 0.4 % (true-rms) (AC) 0.15 % 0.7 % (true-rms) 287/FVF kit includes: Ordering information Included accessories Models Test leads, alligator clips, holster, 9 V battery (installed), users manual on CD, getting started guide. FLUKE-289 True-rms Industrial Logging Multimeter with TrendCapture FLUKE-287 True-rms Electronics Logging Multimeter with TrendCapture FLUKE-289/FVF True-rms Industrial Logging Multimeter Combo Kit with TrendCapture FLUKE-287/FVF True-rms Electronics Logging Multimeter Combo Kit with TrendCapture For more information, go to www.fluke.com/dmm • True-rms electronic logging multimeter with TrendCapture • FlukeView Forms Software and cable • Temperature probe • Modular test leads (red, black) • Modular test probes (red, black) • Alligator clips (red, black) • Soft case Check price and availability at www.fluke.com/wtb Digital Multimeters 11 Fluke 87V Industrial Multimeter For industrial productivity The Fluke 87V has measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in-plant automation, power distribution and electro-mechanical equipment. • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and electrically noisy equipment (87V and 87V Ex) • Large digit display with bright two level backlight makes the 87V significantly easier to read • Measure 20 A for up to 30 sec, 10 A continuously • Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks (TPAK) • Expanded capacitance range to 10,000 µF Specialty models Fluke 87V Ex Intrinsically Safe True-rms Multimeter See page 39 for more information. Electrical safety All inputs are protected to CAT III 1000 V and CAT IV 600 V. They can withstand impulses in excess of 8,000 V to help protect you from arc blast resulting from surges and spikes. Recommended accessories Available in intrinsically safe version as the Fluke 87V Ex. Also available as 83V average responding multimeter, see below for specifications. Made in the U.S.A. of U.S. and non U.S. parts TPAK TL220 Magnetic Meter Hanger See page 62 SureGrip Industrial Test Lead Set See page 55 True RMS Features Features 87V Ex • 87V • 83V Measure up to 1000 V ac and dc • • • Auto and manual ranging for maximum flexibility • • • Analog bargraph • • • Frequency to 200 kHz and % duty cycle • • • Min/Max and average recording to capture variations automatically • • • Relative mode to remove test lead resistance from low ohms measurements • • • Access door for fast battery changes without breaking the calibration seal • • • One-year • • Peak capture to record transients as fast as 250 µs Limited lifetime warranty PV350 i400 Pressure-Vacuum Module See page 63 AC Current Clamp See page 60 L210 CXT80 Probe Extender with Light See page 62 Extreme Case See page 54 Recommended kits Specifications Basic accuracy Functions Range and resolution 87V DC volts 83V 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.05 % 0.1 % AC volts 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.7 % (true-rms) 0.5 % DC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A 0.2 % 0.4 % AC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A 1.0 % (true-rms) 1.2 % Temperature (excl. probe) -200 °C to 1090 °C (-328 °F to 1994 °F) 80BK Temperature Probe -40 °C to 260 °C (-40 °F to 500 °F) Resistance 600.0 1, 6.000 k1, 60.00 k1, 600.0 k1, 6.000 M1, 50.00 M1 0.2 % Capacitance 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 9,999 µF 1.0 % 1.0 % Frequency 199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz 0.005 % 0.005 % 1.0 % 2.2 °C or 2 % 0.4 % Battery life: 400 hours typical with backlight off. Size (LxWxD): 201 mm x 98 mm x 52 mm (7.9 in x 3.8 in x 2 in). Weight: 355 g (22 oz). Ordering information Included accessories Models Test leads, alligator clips, holster, 9 V battery (installed), temperature probe (87V only), users manual on CD, operator’s guide. FLUKE-87-5 Industrial True-rms Multimeter with Temperature FLUKE-83-5 Industrial Multimeter FLUKE-87V Ex Intrinsically Safe True-rms Multimeter FLUKE-87-5/E2 Industrial Electrician’s Combo Kit Fluke 87V/E2 Industrial Electrician’s Combo Kit • Industrial multimeter • Lightweight soft case to provide optimal protection and storage • 1.5 m silicone leads resist heat • Removable probes with 4 mm of exposed metal for use on industrial circuits • Retractable long reach alligator clips • Meter hanging accessory • Type K temperature probe Check price and availability at www.fluke.com/wtb 12 Digital Multimeters For more information, go to www.fluke.com/dmm Fluke 170 Series Digital Multimeters For maintenance and field service The Fluke 179 True-rms Multimeter has the features needed to find most electrical and HVAC problems. Simple to use with significant improvements over the original Fluke 70 Series. • Wide 1000 V measurement range • True-rms for precise measurement of non-linear signals • Capacitance, resistance, continuity and frequency • Built-in thermometer (Fluke 179 only) • Large, easy-to-read display • Backlight for work in dimly lit areas (Fluke 177 and179 only) • Min/Max/Avg to record signal fluctuations • Display hold and auto hold • Manual and automatic ranging Recommended accessories TPAK TL238 Magnetic Meter Hanger See page 62 Test Lead Set for High Energy Environments See page 57 Electrical safety All inputs are protected to measurement CAT III 1000 V and CAT IV 600 V. This meter can withstand transient impulses in excess of 8000 V to help protect you from arc blasts resulting from surges and spikes. Made in the U.S.A. of U.S. and non U.S. parts True RMS FOM i2000 Flex Fiber Optic Meter See page 63 AC Current Clamp See page 60 LVD2 C35 Volt Light See page 62 Soft Carrying Case See page 54 Recommended kits Features Features 179 177 175 Max voltage 1000 • 1000 • 1000 • 0.09 % • 0.15 % True-rms • Temperature Basic dc accuracy 0.09 % • Backlight Min/Max/Avg ToolPak meter hanging kit with magnet Limited lifetime warranty • • • Opt • Opt • Opt • Specifications Functions DC voltage Range and resolution Best accuracy 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 0.09 % (Models 177 and 179) ± 0.15 % (Model 175) ± 1.0 % of reading AC voltage1 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V DC current 60.00 mA, 400.0 mA, 6.000 A, 10.00 A 2 ± 1.0 % of reading AC current 2 60.00 mA, 400.0 mA, 6.000 A, 10.00 A 2 ± 1.5 % of reading Resistance 600.0 1, 6.000 k1, 60.00 k1, 600.0 k1, 6.000 M1, 50.00 M1 ± 0.9 % of reading Capacitance 1000 nF, 10.00 µF, 100.0 µF, 9999 µF ± 1.2 % of reading Frequency 3 99.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz ± 0.1 % of reading -40 ºC to +400 ºC (-40 ºF to +752 ºF) 1.0 % of reading Temperature (Model 179) 1All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range. 210 A continuous, 20 A for up to 30 seconds. 3Voltage frequency is specified from 2 Hz to 100 kHz. Current frequency is specified from Ordering information Models Test leads, 9 V battery (installed) and manual. The Fluke 179 comes with an additional temperature probe. FLUKE-179 Digital Multimeter FLUKE-175 Digital Multimeter FLUKE-177 Digital Multimeter FLUKE-179/1AC-II Electricians Combo Kit FLUKE-179/EDA2 Electronics Combo Kit • • • • • • • True-rms digital multimeter Soft case Electronic test probes SureGrip™ silicone test leads SureGrip™ heavy duty hook clips Type K temperature probe Meter hanging accessory 2 Hz to 30 kHz. Battery life: 200 hours typical for alkaline. Size (HxWxL): 4.3 cm x 9.0 cm x 18.5 cm (1.7 in x 3.5 in x 7.3 in). Included accessories 179/EDA2 Electronics Multimeter and Deluxe Accessory Combo Kit 179/1AC-II Electrician’s Multimeter and Voltage Tester Combo Kit • • • • • • • • True-rms digital multimeter Non-contact voltage detector Soft case Alligator clips SureGrip™ test probes Silicone test leads, 1.5 m Type K temperature probe Meter hanging accessory Check price price and and availability availabilityat at www.fluke.com/wtb www.fluke.com/wtb For more information, go to www.fluke.com/dmm Digital Multimeters 13 Fluke 117 and 115 True-rms Digital Multimeters The 117 Digital Multimeter includes integrated noncontact voltage detection to help get the job done faster. The Fluke 115 Digital Multimeter is the solution for a wide variety of electrical and electronic testing applications. • VoltAlert ™ technology for integrated non-contact voltage detection (117) • AutoVolt feature for automatic ac/dc voltage selection (117) • LoZ: Low input impedance prevents false readings due to “ghost voltage” (117) • Large display and white LED backlight to work in poorly lit areas more effectively • Compact ergonomic design for one-handed operation • Min/Max/Avg to record signal fluctuations • Compatible with optional magnetic hanger (TPAK) for hands free operation • Current measurement 20 A (30 seconds momentary; 10 A continuous) • Resistance, continuity, frequency and capacitance Fluke 117 Specialty model Fluke 113 • Basic electrical and utility multimeter • VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity • True-rms for accurate ac measurements on non-linear loads • Record signal fluctuations using the Min/Max function • Diode and capacitance measurements • Integral holster with probe holders for easy storage • Auto and manual ranging for added user functionality • Meets CAT III 600 V and CAT IV 300 V standards for a higher level of safety Fluke 115 Recommended accessories True RMS Features Features 117 VoltAlert ™ • 115 AutoVolt/LoZ • Analog bargraph • • • Large backlit digital display • • • True-rms for accurate measurements on non-linear loads • • • Min/Max recording • • • Display hold • • • 3-1⁄2 digits • • • 6000 counts • • • CAT III 600 V safety rated • • • Three-year warranty • • • TPAK TL220 Magnetic Meter Hanger See page 62 SureGrip Industrial Test Lead Set See page 55 113 LoZ LVD2 C35 Volt Light See page 62 Soft Carrying Case See page 54 Recommended kits Specifications Functions 117 115 113 Accuracy Volts ac/dc 600 V 600 V 600 V 0.5 % + 2 Current ac/dc 10 A 10 A 40 M1 40 M1 60 k1 0.9 % + 2 Resistance Capacitance 1 nF to 9,999 µF 1 nF to 9,999 µF Diode test Yes Yes Frequency 5 Hz to 50 kHz 5 Hz to 50 kHz 1.0 % + 3 1.9 % + 2 Yes 0.1 % + 2 Ordering information 117/322 Electrician’s Combo Kit Included accessories Models Test leads, holster, users manual and 9 V battery (installed). FLUKE-117 Multimeter with Non-Contact Voltage FLUKE-115 Multimeter FLUKE-113 Utility Meter FLUKE-117/322 Electrician’s Combo Kit • True-rms digital multimeter with non-contact voltage detection • Compact clamp meter • Test lead set • Magnetic meter hanging strap • Deluxe carrying case with shoulder strap Check price and availability at www.fluke.com/wtb 14 Digital Multimeters For more information, go to www.fluke.com/dmm Fluke 116 and 114 Digital Multimeters HVAC/R and electrical troubleshooting The Fluke 116 Digital Multimeter was specifically designed for the HVAC professional. The Fluke 114 Digital Multimeter is the best troubleshooting tool for “go/no-go” testing. • Built in thermometer for HVAC applications (116) • Microamps to test flame sensors (116) • AutoVolt: Automatic ac/dc voltage selection (114) • LoZ: Helps prevent false readings due to ghost voltage • Min/Max/Avg to record signal fluctuations • Resistance, continuity, frequency and capacitance • Large white LED backlight to work in poorly lit areas • Compact ergonomic design for one-handed operation • Compatible with optional magnetic hanger (TPAK) Recommended accessories Fluke 116 80AK-A 80PK-24 DMM Adapter See page 59 SureGrip Air Temperature Probe See page 58 80PK-18 80BK-A Pipe Clamp Temperature Probe Kit See page 58 Integrated Temperature Probe See page 58 Recommended kits Fluke 116 Fluke 114 True RMS Features Features 116 114 116/322 HVAC Combo Kit Temperature • Microamps • Frequency • Capacitance • Diode test • AutoVolt/LoZ • • Analog bargraph • • Large backlit digital display • • True-rms for accurate measurements on non-linear loads • • Min/Max recording • • Display hold • • 3-1⁄2 digits • • 6000 counts • • CAT III 600 V safety rated • • Three-year warranty • • • • • • • • • • HVAC multimeter with temperature and microamps Compact clamp meter Test lead set Pipe wrap thermocouple Thermocouple adapter Thermocouple bead probe Meter hanging accessory Deluxe carrying case with shoulder strap Specifications Functions Range and resolution Best accuracy Volts ac/dc 600 V 0.5 % + 2 Current ac/dc (116 only) 600.0 µA 1.0 % + 2 Temperature (116 only) +400 °C 1.0 % + 18 40 M1 0.9 % + 2 1 nF to 9,999 µF 1.9 % + 2 5 Hz to 50 kHz 0.1 % + 2 Resistance Capacitance (116 only) Frequency (116 only) Ordering information Included accessories Models Test leads, integrated temperature probe (116 only), holster, users manual and 9 V battery (installed). FLUKE-114 Electrical Multimeter FLUKE-116/62 HVAC Combo Kit FLUKE-116/322 HVAC Combo Kit FLUKE-116 116/62 HVAC Combo Kit • • • • • • • • HVAC multimeter with temperature and microamps Infrared thermometer Test lead set Pipe wrap thermocouple Thermocouple adapter Type K integrated temperature probe Magnetic meter hanging strap Deluxe carrying case with shoulder strap HVAC Multimeter with Temperature and Microamps Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/dmm Digital Multimeters 15 Fluke 88V and 77 IV Digital Multimeters For automotive, field service or bench repair uke 88V Automotive Multimeter e Fluke 88V Automotive Multimeter is designed to p automotive professionals solve problems faster. is DMM has the measurement functions, troubleshootg features and accuracy to solve virtually any problem th conventional and hybrid vehicles. Automotive test functions include dc and ac voltage, resistance and current Min/Max recording for logging the highest and lowest readings over time Frequency measurements for magnetic sensors and ac/dc frequency signals Duty cycle for variable duty cycle signals with selectable trigger, slope and level Pulse width for fuel injector on-time measurements Conductance testing for secondary ignition coils RPM measurements for DIS and conventional ignition systems Built-in thermometer Made in the U.S.A. of U.S. and non U.S. parts Recommended accessories Fluke 88V TP40 TP88 Automotive Back Probe Pin Set See page 56 Rigid Back Probe Pin Set See page 56 TLK281 TLK282 Automotive Test Lead Kit See page 56 Deluxe Automotive Test Lead Kit See page 56 Fluke 77 IV Fluke 77 IV Digital Multimeter The 77 IV Digital Multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view. • Wide 1000 V measurement range • Average responding ac measurements • 0.3 % accuracy • 10 amps continuous • Frequency and capacitance • Resistance and continuity • Large display • Backlight for work in dim areas • Min/Max to record signal fluctuations • Integral holster with probe holders • Free your hands with the optional TPAK magnetic hanger • Auto and manual ranging TPAK i400 Magnetic Meter Hanger See page 62 AC Current Clamp See page 60 TL225 TLK-225 SureGrip Stray Voltage Adapter Test Lead Kit SureGrip Master Accessory Kit See page 55 Recommended kits Made in the U.S.A. of U.S. and non U.S. parts Specifications (77 IV) Range Best accuracy V dc Functions 600.0 mV to 1000 V ± (0.3 % + 1) 0.1 mV V ac 6.000 V to 1000 V ± (2.0 % + 2) 1.0 mV A dc 60.00 mA to 10 A ± (1.5 % + 2) 0.01mA A ac 60.00 mA to 10 A ± (2.5 % + 2) 0.01 mA Resistance 600.0 Ω to 50 MΩ ± (0.5 % + 1) 0.1 Ω Capacitance 1 nF to 9,999 µF ± (1.2 % + 2) 1 nF 99.99 Hz to 99.99 kHz ± (0.1 % + 1) 0.01 Hz Frequency Best resolution Ordering information Included accessories Models Test leads, carrying case (88V only), users manual and 9 V battery (installed). FLUKE-88-5 Automotive Multimeter FLUKE-77-4 Digital Multimeter FLUKE-88-5/A KIT Automotive Multimeter Combo Kit • • • • • • • • • • Automotive multimeter Heat resistant silicone test leads Removable sharp point test probes Large jaw alligator clips Temperature probe Inductive pick-up Automotive backprobe pins Insulation piercing probe Meter hanging accessory Durable carrying case Check price and availability at www.fluke.com/wtb 16 Digital Multimeters For more information, go to www.fluke.com/dmm Fluke 1587 and 1577 Insulation Multimeters Two powerful tools in one The Fluke 1587 and 1577 Insulation Multimeters combine a digital 1 kV insulation tester with a full-featured, truerms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventive maintenance. • Insulation test (1587: 0.01 MΩ to 2 GΩ) (1577: 0.1 MΩ to 600 MΩ) • Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V), (1577: 500 V, 1000 V) for many applications • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection • Auto-discharge of capacitive voltage for added user protection • Filter for motor drive measurements (1587 only) • AC/DC voltage, dc millivolts, ac/dc milliamps, resistance (W), and continuity • Capacitance, diode test, temperature, Min/Max, and frequency (Hz) (1587 only) • Auto power off to save battery power • Large display with backlight and large digits • Included accessories: Remote probe, test leads and probes, alligator clips, (Type K thermocouple, 1587 only) • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work • Rugged, utility hard case allows you to bring everything you need for the job Fluke 1577 Fluke 1587 Recommended accessories TPAK i400s Magnetic Meter Hanger See page 62 AC Current Clamp See page 60 C25 TL27 Meter Case See page 54 Heavy Duty Test Leads Recommended kits Get more value and productivity Establishing a preventive maintenance program is becoming critical to maintaining the uptime of electrical equipment and can significantly reduce both planned and unplanned downtime. Unplanned downtime costs are difficult to calculate, but are often significant. For some industries, it can represent 1 % to 3 % of revenue (potentially 30 % to 40 % of profits) annually. These kits can help you be proactive and efficient with your maintenance and can save you up to 10 % off the individual price of the tools. True RMS Specifications Features 1587 Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V 1577 • Auto-discharge of capacitive voltage 1503 • • Insulation test voltages 500 V, 1000 V Insulation resistance 1507 0.01 M1 to 2.0 G1 • 0.1 M1 to 600 M1 • • 0.01 M1 to 10 G1 • 0.1 M1 to 2 G1 • Insulation test smoothing reading • Frequency • Capacitance • Diode test • Temperature • Min/Max • Low-pass filter (for work on VSDs) • AC/DC Voltage • • DC millivolts • • AC/DC milliamps • • 0.1 1 to 50 M1 • 0.1 1 to 50 M1 • 0.1 1 to 20.00 K1 0.1 1 to 20.00 K1 Three-year • Three-year • One-year • One-year • Resistance Continuity Warranty Remote probe, test leads, alligator clips Fluke 1587/ET Advanced Electrical Troubleshooting Kit includes: • Fluke 1587 Insulation Multimeter • Fluke i400 Current Clamp • Fluke 62 Mini Infrared Thermometer • Type K thermocouple Rugged, utility hard case • • • • Auto power off • • • • Page number 17 17 24 24 Fluke 1587/MDT Advanced Motor and Drive Troubleshooting Kit includes: • Fluke 1587 Insulation Multimeter • Fluke i400 Current Clamp • Fluke 9040 Phase Rotation Indicator Ordering information Included accessories Models Remote probe, test leads, alligator clips, Type K thermocouple (1587 only), hard case and users manual. FLUKE-1577 Insulation Multimeter FLUKE-1587 Insulation Multimeter FLUKE-1587/ET Advanced Electrical Troubleshooting Kit FLUKE-1587/MDT Advanced Motor and Drive Troubleshooting Kit Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/dmm Digital Multimeters 17 Fluke 421D, 416D and 411D Laser Distance Meters The Fluke laser distance meters offer the most advanced measuring technology available. Unlike ultrasonic distance meters with laser pointers, these meters use a precision narrow laser beam that helps avoid the common errors caused by extraneous objects near measurement targets. • Eliminate estimation errors, saving both time and money • Instant measurement with one-button operation • Easy targeting with bright laser • Quick calculation of area (square footage) and volume • Easy addition and subtraction of measurements • Two-year warranty Application tip Ways laser distance meters save time and money 1. Fast measurements: Point. Click. The measurement is done. 2. Easy access: High ceiling? Obstacles in the way? Just aim the laser. 3. One man operation: Your helper can do other jobs. 4. Longer distances: Up to 100 meters (330 feet). 5. Calculations: Add and subtract distances. Find area and volume. Even calculate height using Pythagorean math. See why Chip Wade and other experts use distance meters. www.fluke.com/ldm-video Fluke 416D Fluke 411D Specifications Recommended kits Features Range (for extended distances, use a target plate)* Measuring accuracy** Fluke 421D Fluke 416D Fluke 411D 0.05 m to 100 m (0.16 ft to 330 ft) 0.05 m to 60 m (0.16 ft to 200 ft) 0.1 m to 30 m (0.33 ft to 100 ft) ± 3 mm (0.118 in) ± 1.5 mm (± 0.059 in) ± 1.5 mm (± 0.059 in) Laser class II II II Laser type 635 nm, < 1 mW 635 nm, < 1 mW 635 nm, < 1 mW Automatic power off after 180 seconds After 180 seconds after 180 seconds Continuous measurement • • • Addition/subtraction • • • up to 5,000 measurements up to 3,000 measurements up to 3,000 measurements • • — 20 10 — Battery life LCD illumination Data locations Min/Max • • — Audible feedback • • — Simple Pythagoras (Indirect measurement) Full Full Room angle and stakeout • — — ±45 ° Tilt sensor/indirect measure • — — Ingress protection Dimensions IP54 IP54 IP40 127 mm x 52 mm x 29 mm (5.00 in x 2.06 in x 1.13 in) 135 mm x 46 mm x 31 mm (5.31 in x 1.81 in x 1.22 in) 123 mm x 50 mm x 26 mm (4.84 in x 1.97 in x 1.02 in) 125 g (4.40 oz) 110 g (3.88 oz) 150 g (5.29 oz) -25 °C to 70 °C (-13 °F to 158 °F) 0 °C to 40 °C (32 °F to 104 °F) -25 °C to 70 °C (-13 °F to 158 °F) 0 °C to 40 °C (32 °F to 104 °F) -25 °C to 70 °C (-13 °F to 158 °F) 0 °C to 40 °C (32 °F to 104 °F) Weight Temperature range Storage Operation Operating altitude (ISO 9022) Storage humidity (at 35 °C) up to 3500 m up to 3500 m up to 3500 m maximum 85 % for 24 h maximum 85 % for 24 h maximum 85 % for 24 h AAA (2) AAA (2) AAA (2) Batteries * In favorable conditions (optimal target surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as intensive sunshine, very weakly reflecting target surface, or large temperature fluctuations, measuring accuracy may deteriorate to approx. ± 0.25 mm/m (± 0.003 in/ft) for distances above 10 m (33 ft). ** In favorable conditions (optimal target surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as intensive sunshine, very weakly reflecting target surface, or large temperature fluctuations, the deviation over distances 10 m (33 ft) can increase by approx. ± 0.15 mm/m (± 0.0018 in/ft). Ordering information 18 Models Two AAA batteries, users manual on CD, quick start guide, nylon carrying case. FLUKE-421D Laser Distance Meter FLUKE-416D Laser Distance Meter FLUKE-411D Laser Distance Meter FLUKE-411D/62 411D Laser Distance Meter and 62 IR Thermometer Kit FLUKE-9040 Rotary Field Indicator Laser Distance Meters Other products Fluke 9040 Rotary Field Indicator The Fluke 9040 is a premium phase rotation tester with a CAT III, 600 V rating. The frequency range is from 15 Hz to 400 Hz for demanding applications. The clear liquid crystal display and the holster make it suitable for rough outdoor applications. This instrument is supplied with three unique, expandable test probes that fit most sockets. Includes a two-year warranty. For more information, go to www.fluke.com/9040 Included accessories Three self-retaining test probes (black), alligator clip, users manual. • Fluke 62 Mini Thermometer • Soft pouch for each model Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/distance Fluke 1625 and 1623 Geo Earth Ground Testers The Fluke 1625 and 1623 Earth Ground Testers not only measure ground resistance using the classic “fall of potential test,” but also enable time saving testing using “selective” and “stakeless” methods. “Selective” testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple “stakeless” method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test. Offering “one-button” simplicity, the 1623 is an all-in-one earth ground tester, while the 1625 has extra versatility for more demanding applications. The 1623 is perfect for performing predictive maintenance checks of commercial and industrial applications. The 1625 is intended for electrical utility or other electrically noisy environments. Fluke 1625 Earth ground resistance and soil resistivity should be measured when: • Designing earth ground systems • Installing new ground system and electrical equipment • Periodically testing ground and lightning protection systems • Installing large electrical equipment such as transformers, switchgears, machines, etc. Fluke 1623 Recommended accessories EI-1623 EI-1625 Selective/stakeless clamp set for 1623 Selective/stakeless clamp set for 1625 ES-162P3 ES-162P4 Stake/reel set for 3-pole measurements Stake/reel set for 4-pole measurements EI-162BN Split Core Transformer for use with Fluke 1625 Recommended kits Specifications Features 1625 One-button measurement concept 1623 1621 • • • 3-pole earth ground measurement • • 4-pole earth ground measurement • • 4-pole soil resistivity testing • • 2-pole resistance measurement ac • • 2-and 4-pole resistance measurement dc • Selective testing, no disconnection of ground conductor (1 clamp) • • Stakeless testing, quick ground loop testing (2 clamps) • • • Measuring frequency 128 Hz Earth impedance measurement at 55 Hz • Automatic frequency control (AFC), 94 Hz to 128 Hz • Measuring voltage switchable 20 V/48 V • Programmable limits, settings • Continuity with buzzer • Dust/water resistance Safety rating Two-year warranty • Fluke 1625 Kit • • • • • • • Fluke 1625 tester 2 test leads 4 earth ground stakes 3 cable reels with wire (2-25 m, 1-50 m) 2 clamps (one inducing, one sensing) Rugged carrying case • IP 56 IP 56 IP 40 CAT II 300 V CAT II 300 V CAT II 600 V • • • * In favorable conditions (optimal target surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as intensive sunshine, very weakly reflecting target surface, or large temperature fluctuations, measuring accuracy may deteriorate to approx. ± 0.25 mm/m (± 0.003 in/ft) for distances above 10 m (33 ft). ** In favorable conditions (optimal target surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as intensive sunshine, very weakly reflecting target surface, or large temperature fluctuations, the deviation over distances 10 m (33 ft) can increase by approx. ± 0.15 mm/m (± 0.0018 in/ft). Ordering information Fluke 1623 Kit Included accessories Models Test leads, alligator clips, users manual. FLUKE-1625 Advanced GEO Earth Ground Tester FLUKE-1623 Basic GEO Earth Ground Tester Test leads, alligator clips, stake/reel set 4-pole, selective/ stakeless clamp set, rugged carrying case, users manual. FLUKE-1625 KIT Advanced GEO Earth Ground Tester Kit FLUKE-1623 KIT Basic GEO Earth Ground Tester Kit • • • • • • Fluke 1623 tester 2 test leads 4 earth ground stakes (2-25 m) 3 cable reels with wire (2-25 m, 1-50 m) 2 clamps (one inducing, one sensing) Rugged carrying case These products are for unpowered installations measuring grounding connections. Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/egt Earth Ground Testers 19 Fluke 1621 Basic Earth Ground Tester Earth ground tester for resistance measurement The Fluke 1621 Earth Ground Tester is a rugged, easy-touse tester for three-pole ground resistance measurements and two-pole ac resistance measurements. Earth ground resistance is measured by installing earth ground test electrodes, and testing with the Fluke 1621. Earth ground resistance measurements are used to ensure safe operation and reduce power quality problems. With a simple user interface and intuitive functionality, the large, clear LCD display provides high visibility results in daylight or poor lighting conditions. The 1621 is lightweight making it ideal to test for lightning protection levels and periodic check-ups during routine maintenance. • Three-pole earth resistance measurements • Two-pole ac resistance measurements • AC/DC voltage measurement • Large dual backlit display • Limit settings for automatic measurement evaluation • CAT II 600 V • Two-year warranty Feature comparison on page 19. Fluke 1630 Earth Ground Clamp Meter Application tip What is grounding, and what does it do? The NEC, National Electrical Code, defines a ground as a “conducting connection, whether intentional or accidental between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of the earth.” Earth grounding is an intentional connection from a circuit conductor, usually the neutral, to a ground electrode placed in the earth. Equipment grounding is to ensure that operating equipment within a structure is properly grounded. These two grounding systems are required to be separate except for a connection between the two systems to prevent differences in potential from a possible flashover from a lightning strike. The purpose of a ground, besides the protection of people, plants and equipment, is to provide a safe path for the dissipation of fault currents, lightning strikes, static discharges, EMI and RFI signals and interference. Recommended accessories The Fluke 1630 Earth Ground Clamp Meter is able to measure ground loop resistances—using the stakeless testing method. This test technique eliminates the dangerous, and time consuming activity, of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary ground stakes. You can also perform earth ground tests in places you have not considered before: inside buildings, on power pylons or anywhere you don’t have access to soil. With the stakeless testing method, the Fluke 1630 Earth Ground Clamp Meter is placed around the earth ground rod or the connecting cable. No earth ground stakes are used at all. A known voltage is induced by one half of the clamp and the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system—a major time saver. • Quick and easy use—no earth ground stakes are necessary • Large, 35 mm (1.35 in) jaw opening • Measures ground resistance from 0.025 Ω to 1500 Ω • Measures ground leakage current from 0.2 mA to 30 A • High and low alarming • Automatic self calibration • Rugged carrying case and resistance check loop included • Two-year warranty Cable Reel 50 m Cable Reel 25 m Ground/earth wire (162.5 ft) Ground/earth wire (81.25 ft) ES-162P3 Earth Stake Stake/reel set for 3-pole measurements Ground/earth stake Recommended kits Ordering information Fluke 1621 Tester Included accessories Models Two measuring leads with alligator clips, 2 m (6 ft), yellow protective holster, 9 V alkaline battery (LR61), users manual, CD. FLUKE-1621 Basic Earth Ground Tester 1-50 m cable reel, 1-25 m cable reel, 3 earth stakes, 2 test leads, 2 alligator clips, carrying case, yellow protective holster, 9 V alkaline battery (LR61), users manual, CD. FLUKE-1621 KIT Basic Earth Ground Tester Kit Rugged carrying case with belt, resistance test loop, 9 V battery, users manual. FLUKE-1630 Earth Ground Clamp Meter These products are for unpowered installations measuring grounding connections. 20 Earth Ground Testers • • • • • 2 cable reels with wire (1-50m, 1-25m) 3 earth ground stakes 1 Test lead (red and black 2m) 2 Alligator Clips Hard carrying case Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/egt Fluke T5, T+PRO, T+ Electrical Testers and VoltAlert ™ Fluke T+PRO and T+ Electrical Testers Recommended accessories • Three forms of ac/dc voltage detection: Light, sound and vibration • Detects live voltage even when batteries are dead • Extra heavy-duty, replaceable test leads • Rotary field indicator for troubleshooting three-phase systems • Continuity beeper, LED flashlight and GFCI trip H5 Meter Cleaner Electrical Tester Holster See page 54 Cleaning Wipes Fluke T5 Voltage, Continuity and Current Testers • Excellent front-line troubleshooting and measurement tool • Available in 600 V and 1000 V models • Digital display • OpenJaw™ current measurement • Rotary switch selects volts, amps and ohms functions • Heavy-duty test leads Fluke T5-1000 Fluke VoltAlert™ Family The next generation VoltAlert™ ac non-contact voltage testers from Fluke are easy to use. Electricians, maintenance, service and safety personnel, and homeowners can quickly test for energized circuits in the workplace or at home. Certified up to CAT IV 1000 V. Functions T+PRO T+ T5-1000 T5-600 1000 V 600 V Preset 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V (Canada 347 V), 480 V, 600 V Measure ac current (average) Measure continuity Yes Measure resistance 9.99 k1 Yes 100 A 100 A < 25 1 < 25 1 1000 1 1000 1 Yes Yes Yes DC polarity indicator Detachable probe tips with optional probe tips styles Yes Yes Yes Digital display Yes No Yes Yes CAT IV 600 V/ CAT III 1000 V CAT IV 600 V/ CAT III 1000 V 1000 V Overvoltage CAT III 600 V Overvoltage CAT III Two-year Two-year Two-year Two-year Safety rating Warranty *Voltage levels will vary depending on country of intended use. Functions Voltage range 2AC 1AC-II 1LAC-II LVD2 90 V ac to1000 V ac 90 V ac to1000 V ac 20 V ac to 90 V ac 90 V ac to 600 V ac • • • Always on • • • CAT IV 1000 V CAT IV 1000 V CAT IV 1000 V CAT IV 600 V Audible alert Safety rating Recommended kits T+PRO-1AC Kit • Fluke T+Pro Electrical Tester • 1AC-II VoltAlert ™ • Fluke 62 Non-conta Thermometer • T+RO Electrical Tes • 1AC-II VoltAlert™ • Carrying case T5-1000 Tester Kit • Fluke T5-1000 Voltage Electrical Tester • 2AC VoltAlert ™ Voltage Detector • Fluke H5 Holster • Flashlight On/Off C520A Premium Leather Holster See page 54 62/T+PRO/1AC-II Specifications Measure ac/dc voltage T5 Kit Starter Kit See page 55 VoltAlert ™ Multi Pack Includes five Fluke VoltAlert ™ voltage detectors. The special kit pricing gets you the fifth VoltAlert ™ free. Ordering information Included accessories Models The T+ and T+PRO come with attached test probes, lead wrap, users manual. T+PRO and T+PRO CAN Electrical Tester T+ and T+ CAN Electrical Tester T+PRO-1AC KIT Electrical Tester and AC Voltage Detector Kit T+PRO CAN-1AC KIT Electrical Tester and AC Voltage Detector Kit 62-T+PRO-1AC KIT IR Thermometer, Electrical Tester and AC Voltage Detector Kit T5-1000 1000 V Voltage, Continuity and Current Tester T5-600 600 V Voltage, Continuity and Current Tester T5-H5-1AC KIT Voltage, Continuity and Current Tester Kit The T5-1000 and T5-600 come with detachable probes and instruction sheet. 2AC VoltAlert ™ Voltage Detector 2AC 5PK VoltAlert ™ Voltage Detector 5 Pack 1AC-II VoltAlert ™ Voltage Detector 1AC-II 5PK VoltAlert ™ Voltage Detector 5 Pack 1LAC-II VoltAlert ™ Voltage Detector LVD2 Volt Light For more information, go to www.fluke.com/electricaltesters Check price and availability at www.fluke.com/wtb Electrical Testers 21 Fluke 975 AirMeter™ Simple, one-touch air velocity The Fluke 975 AirMeter ™ combines five powerful air quality tools into one. Identify and diagnose indoor air quality issues quickly and easily with one rugged, handheld device. The Fluke 975 measures and simultaneously displays temperature, humidity, CO2 and CO. At the press of a button, it quickly measures air flow and percentage of outside air. • Simultaneously measures, logs and displays temperature, humidity, CO2 and CO on a bright, backlit LCD display • % of outside air calculation • One-touch air flow and velocity with available probe* • Dew point and wet bulb temperature • CO2 and CO field calibration feature • Min/Max/Avg on all measured and calculated readings • Audible and visual threshold alarms • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface • Includes NIST-traceable certificate of calibration • Automatically compensates for barometric pressure changes • Two-year warranty Recommended accessories Fluke-975VP AirMeter Velocity Probe for use with Fluke 975 AirMeter. Recommended kits Fluke-975CK AirMeter Calibration Kit includes the gases and tools necessary to keep your Fluke 975 AirMeter calibrated. *Included with Fluke 975V, optional with Fluke 975. Fluke 922 Airflow Meter/Micromanometer Make airflow measurements easy by combining differential pressure, air flow, and velocity into a single, rugged meter. Used with any pitot tube, the Fluke 922 is the perfect entry point for technicians measuring air flow for the first time, yet powerful enough for advanced users. • Measures differential and static pressure, air velocity and flow readings • User-defined duct shape and size for maximum airflow accuracy • Bright, backlit display • Min/Max/Avg/Hold functions • Auto power off Fluke 975V • • • • • • • • • AirMeter™ Calibration cap Air velocity probe FlukeView® Forms software Power adapter International power plugs Hard carrying case Three AA alkaline batteries Users manual with safety information Specifications 975 features Temperature Relative humidity Air velocity Range Display resolution Accuracy -20 °C to 50 °C (-5 °F to 122 °F) 0.1 °C (0.1 °F) ± 0.9 °C/± 1.62 °F from 40 °C to 60 °C ± 0.5 °C/ ± 1.00 °F from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C 10 % to 90 % RH non-condensing 1% ± 2 % RH (10 % RH to 90 % RH) 50.0 fpm to 3000 fpm 0.25 m/sec to 15 m/sec 1 fpm (0.005 m/sec) ± 4 % or 4 fpm* ± 4 % or 0.02 m/sec* whichever is greater * Accuracy specification only valid for velocity readings above 50 fpm 0 to 5000 ppm 1 ppm Warm up time 1 min (5 minutes for full specification) 2.75 % + 75 ppm 0 to 500 ppm 1 ppm ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH CO2 CO 922 features Air pressure Range Accuracy ± 4000 Pascals / ± 16 in H2O / ± 400 mm H2O / ± 40 mbar / ± 0.6 PSI ± 1 % + 1 Pascal / ± 1 % + 0.01 in H2O / ± 1 % + 0.1 mm H2O / ± 1 % + 0.01 mbar / ± 1 % + 0.0001 PSI Air velocity Air flow (volume) 250 to16,000 fpm (1 to 80 m/s) ± 2.5 % of reading at 2000 fpm (10.00 m/s) 0 to 99,999 cfm; 0 to 99,999 m 3/hr; 0 to 99,999 l/s Accuracy is a function of velocity and duct size 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F) Temperature Data storage Warranty Power Fluke 922/Kit • • • • • • • • • Airflow meter 12 inch pitot tube Two rubber hoses TPak magnetic strip TPak strap, 9 inches TPak latch tab Four AA 1.5 V alkaline batteries Users manual Hard carrying case 99 readings Two-year Four AA batteries Ordering information 22 Included accessories Models Calibration cap, air velocity probe (Fluke 975V only), FlukeView ® Forms software, power adapter, international power plugs, hard carrying case, three AA alkaline batteries, users manual with safety information. FLUKE-975 AirMeter™ FLUKE-975V AirMeter™ with Velocity Two rubber hoses, soft carrying case, four AA alkaline batteries 1.5 V, users manual. FLUKE-922 Airflow Meter 12 inch pitot tube, two rubber hoses, ToolPak Magnetic Meter Hanging Kit, hard carrying case, four AA alkaline batteries 1.5 V, users manual. FLUKE-922/KIT Airflow Meter Kit Indoor Air Quality Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/IAQ Indoor Air Quality Tools Tools to help you maintain good IAQ Fluke 971 Temperature Humidity Meter Temperature and humidity are two important factors in maintaining optimal comfort levels and good indoor air quality. Quickly and conveniently take accurate humidity and temperature readings with the Fluke 971. The Fluke 971 is invaluable for facility maintenance and utility technicians, HVAC-service contractors, and specialists who assess indoor air quality (IAQ). Lightweight and easy to hold, the Fluke 971 is the perfect tool for monitoring problem areas. With a rugged holster and twist-open protective sensor cover, the Fluke 971 is built to perform and made to last. Features: • New and improved digital sensor for faster response times • Backlit dual display of humidity and temperature • Measures dew point and wet bulb temperatures • 99 record storage capacity • Ergonomic design with belt clip and protective holster • Compact and lightweight at 188 g (6.6 oz) • Temperature range from -20 °C to 60 °C (-4 °F to 140 °F) • Relative humidity from 5 % to 95 % • Min/Max/Avg/Hold functions • Low battery indicator • One-year warranty Fluke 983 Particle Counter The Fluke 983 Particle Counter measures and displays six channels of particle size distribution. The Fluke 983 holds 5000 logged samples including date, time, counts, sample volume, temperature and relative humidity. Data is easily downloaded using the included windows compatible utility software. The Fluke 983 is invaluable for IAQ investigations, allowing you to determine size distribution of airborne particles or track down a particle source. Features: • Compact and easy to operate • Graphic liquid crystal display with backlight • Simple connection to computer or printer • Selectable sample time, count data and programmable delay • Set sample size to cubic feet or liters, set temperature measurements to °C or °F • Data displayed in totalize or concentration modes • Automatic turn-off when battery voltage drops below safe operating level • Meets JISB9921:1997 and CE standards • Battery or ac operation with internal rechargeable battery • Protective holster • Rugged, hard shell carrying case • One-year warranty Ordering information Included accessories Models Certificate of Calibration (NIST), Windows compatible software download utility, DB9 to RS-232 adapter and cable, isokinetic probe, high purity tubing, 1/8 inch hose barb adapter, power supply, zero count filter, protective holster and hard molded plastic case, users manual. FLUKE-983 Particle Counter Four AAA alkaline batteries, users manual. FLUKE-971 Temperature Humidity Meter FLUKE-983TPK 220 Thermal Printer Kit, 220 V FLUKE-983TPK 120 Thermal Printer Kit, 120 V FLUKE-CO-205 Aspirator Kit FLUKE-CO-220 Carbon Monoxide Meter FLUKE-RLD2 Refrigerant Leak Detector Flashlight For more information, go to www.fluke.com/IAQ Specialty models Fluke RLD2 UV Refrigerant Leak Detector Flashlight Leak detection made easy. The compact, easy-to-use, RLD2 UV flashlight uncovers refrigerant leaks instantly. Use the UV light to find the leakage area, then, use the laser pointer to pinpoint the exact leak location. With 100,000 hours of life, and four operating modes, this versatile leak detector is a must have for HVAC technicians. • Six UV LEDs (395 nm wavelength) detect leak detection dyes • Laser pointer clearly locates center of the UV field for accuracy • Three LED flashlight with 100,000 hour LED life • Operating temperature 0 °C to 50 °C • Four operating modes: flashlight, UV light, laser light, UV/laser light combination • Convenient detachable key chain carabiner and AAA battery included CO-220 Carbon Monoxide Meter • Stand-alone CO meter that does not require a digital multimeter • Large backlit LCD displays CO levels from 0 to 1000 ppm • Beeper triggers with increasing frequency as CO levels rise • MAX hold function stores and displays the maximum CO level • Automatic sensor zeroing and self-test upon startup CO-205 Aspirator Kit The CO-205 flue gas sampling accessory kit includes: • Stainless steel sampling tube • Aspirator • Replaceab filter • Nose cap connectio the Fluke CO-210/CO-220 Check price and availability at www.fluke.com/wtb Indoor Air Quality 23 Fluke 1507/1503 Insulation Resistance Testers Troubleshooting and predictive maintenance tools These lightweight, affordable insulation testers are perfect for troubleshooting, commissioning and preventive maintenance applications. Features • Automatic calculation of polarization index and dialectric absorption ratio (1507 only) • Multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V (1507 only) • Remote test probe for rapid testing • Insulation test range 0.01 MΩ to 10 GΩ (1507), 0.1 MΩ to 2000 MΩ (1503) • Compare (Pass/Fail) function for repetitive tests (1507 only) • Live circuit detection prevents insulation test if voltage > 30 V is detected • Auto-discharge of capacitive voltage • AC/DC voltage: 0.1 V to 600 V • Lo ohms/Earth-bond continuity (200 mA) for checking connections and motor windings • Resistance: 0.01 Ω to 20.00 Ω • One-year warranty Selection guide Features 1555 1550C Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V 1507 • Insulation test voltages 500 V, 1000 V Insulation resistance Auto-discharge of capacitive voltage 1577 • • • • 2 TΩ 1 TΩ 0.01 MΩ to 10 GΩ 0.1 MΩ to 2 GΩ 0.01 MΩ to 2.0 GΩ 0.1 MΩ to 600 MΩ • • • • • • Insulation test smoothing reading Current measurement • Automatic ranging within the manually selected mA or A range • Ranges 3/30 mA and 30/60 A • Current resolution 1 µA/0.01 mA and 0.01 A/0.1 A • Frequency range 50 and 60 Hz • Jaw size: 40 mm (1.55 in) maximum conductor diameter • Auto power off • • • Recommended accessories • Diode test • Temperature • Min/Max • Low-pass filter (for work on VSDs) • AC/DC voltage • • DC millivolts • • AC/DC milliamps • • 0.1 Ω to 50 MΩ Resistance 0.1 Ω to 20.00 KΩ 0.1 Ω to 20.00 KΩ 0.1 Ω to 50 MΩ • • Warranty (years) 3 3 1 1 3 3 Remote probe, test leads, alligator clips • • • • • • Continuity TPAK TL225 Magnetic Meter Hanger See page 62 Stray Voltage Adapter Test Lead Kit • Type K thermocouple Rugged, utility hard case • • • • • Auto power off • • • • • • 25 25 24 24 17 17 Page number Calculate insulation resistance while equipment is under load by measuring insulation leakage current. The unique jaw design of the Fluke 360 eliminates the influence of adjacent current conductors and measures leakage current down to 1 μA for monitoring of insulation. The ergonomic design of the Fluke 360 ensures easy measuring. The measuring clamp fits into tight spaces and the wide display angle clearly shows the measurement result. The Data Hold button keeps the measured value on the display after removing the clamp for the measured conductor. The Fluke 360 offers the widest range of current measurement. Use the rugged Fluke 360 when it’s not possible to power down and break the circuit. • Frequency Capacitance 1587 • Insulation test voltages: User selectable 250 V to 5000 V Insulation test voltages: User selectable 250 V to 10,000 V 1503 Specialty models Fluke 360 AC Leakage Current Clamp Meter • C25 C101 Meter Case See page 54 Hard Case See page 54 Ordering information Included accessories Models Remote probe, test leads, test probes, alligator clips, holster, users manual. FLUKE-1507 Insulation Tester FLUKE-1503 Insulation Tester FLUKE-360 AC Leakage Current Clamp Meter Soft carrying pouch, users manual. 24 Insulation Resistance Testing Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/1507 1555 and 1550C Insulation Resistance Testers Powerful troubleshooting and predictive maintenance tools The new Fluke 1555 and redesigned Fluke 1550C insulation resistance testers offer digital insulation testing up to 10 kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables. • Test voltages up to 5 kV (1550C) and 10 kV (1555) provide solutions for all applications • Warning function alerts the user that line voltage is present and gives a voltage reading up to 600 V ac or dc for increased user safety • Measurements can be stored in up to 99 memory locations, and each location is assigned a unique, user-defined label for easy recall • Long battery life gives the user over 750 tests between changes • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup • Guard system eliminates the effect of surface leakage current on high-resistance measurements • Large digital/analog LCD for easy viewing • Capacitance and leakage current measurement • Ramp function for breakdown testing • Three-year warranty Application note Insulation resistance testing Insulation resistance testers can be used to determine the integrity of windings or cables in motors, transformers, switch-gear, and electrical installations. The test method is determined by the type of equipment being tested and the reason for testing. For instance, when testing electrical cabling or switchgear (low-capacitance equipment) the time-dependent capacitive leakage and absorption leakage currents become insignificant and decrease to zero almost instantly. A steady conductive leakage current flow is reached almost instantly (a minute or less) providing perfect conditions for the spot-reading/short-time resistance test. www.fluke.com/IRT Specifications The tester’s accuracy is specified for one year after calibration at operating temperatures of 0 °C to 35 °C. For operating temperatures outside the range (-20 °C to 0 °C and 35 °C to 50 °C), add ± .25 % per °C, except on the 20 % bands add ± 1 % per °C. Insulation resistance measurement Recommended kits 1550C/Kit includes: Test voltage (dc) Range Accuracy (± reading) 250 V < 200 kΩ 200 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ unspecified 5% 20 % unspecified 500 V < 200 kΩ 200 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ unspecified 5% 20 % unspecified 1000 V < 200 kΩ 200 kΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ unspecified 5% 20 % unspecified 2500 V < 200 kΩ 200 kΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ unspecified 5% 20 % unspecified 5000 V < 200 kΩ 200 kΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ unspecified 5% 20 % unspecified 10000 V (1555 Only) < 200 kΩ 200 kΩ to 200 GΩ 200 GΩ to 2 TΩ > 2 TΩ unspecified 5% 20 % unspecified Accuracy (± reading) Functions Range Leakage current 1 nA to 2 mA ± (5 % + 2 nA) Capacitance measurement 0.01 uF to 15.00 µF ± (15 % rdg + 0.03 µF) Live circuit indicator 30 V to 600 V ac/dc, 50/60 Hz ± (5 % + 2 V) • • • • 1550C insulation resistance tester Ruggedized alligator clips IP67 hard case NIST traceable certificate of calibration 1555/Kit includes: • • • • 1555 insulation resistance tester Ruggedized alligator clips IP67 hard case NIST traceable certificate of calibration Ordering information Included accessories Models Test leads with alligator clips, ruggedized alligator clips (kits and 1555 only), infrared adapter with interface cable, FlukeView Forms software, ac power cord, soft carrying case, quick reference guide, users manual. FLUKE-1550C 5 kV Insulation Tester FLUKE-1550C/Kit 5 kV Insulation Tester Kit FLUKE-1555 10 kV Insulation Tester FLUKE-1555/Kit 10 kV Insulation Tester Kit Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/1550 Insulation Resistance Testing 25 Fluke 345 Power Quality Clamp Meter The ideal meter to troubleshoot modern electrical loads The Fluke 345 is more than a power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics. • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit • Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically • Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds • Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends • View graphs and generate reports: Use power analyzer with included Power Log software Application tip Set up and troubleshoot variable frequency drives and UPS systems – Verify correct operation by measuring key parameters Harmonics measurements – Uncover harmonic issues that can damage or disrupt critical equipment Inrush capture – Check start-up current where spurious resets or nuisance circuit breaker tripping occurs Load studies – Verify electrical system capacitybefore adding loads View waveforms for equipment checking and setup. Selection guide Single Phase Basic measurements Application use VR1710 Three Phase 345 43B 1735 1740 430 1750 1760 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Energy studies Measure V, I, kW, Cos/ DPF, kWhr Measure MIN/MAX and AVG values 10 day logging Get detailed power and energy consumption profiles during energy audits and pinpoint savings opportunities. Basic harmonics study THD measurement (V & I) Harmonics 1 to 25 for V & I Discover the source of distortion in your installation, so that you can filter those loads or move them to separate circuits. Equipment performance measurement—power consumed by single- and three-phase balanced loads. Advanced harmonics study Full harmonic spectrum Power harmonics If distorting loads are causing problems in your installation, you need comprehensive data to identify the source and create a solution. Recommended accessories Basic industrial PQ troubleshooting* Oscilloscope function When troubleshooting Voltage dips and swells in the field, graphical data enables you to trace the source of the problem at hand. • Advanced industrial PQ troubleshooting** Comprehensive logging capability Transient capture Flicker Complex installations often require a deeper dive into measurement data. Multiple loads may be interacting randomly to cause a single problem. • • • • • • • • • • • • • • • • TP220 AC220 Industrial Test Probes See page 57 Alligator Clips See page 57 For more information and detailed product selector go to: http://www.fluke.com/fluke/usen/products/prodselection?product=pqt&category=pqttop Ordering information Included accessories Models Test leads, alligator clips, test probes, Power Log software, USB cable, international ac adapter/battery eliminator, soft carrying case, users manual, multi-language manual CD. FLUKE-345 TLK291 C550 Fused Test Probe Set Tool Bag See page 54 Clamp-On Power Meter Check price and availability at www.fluke.com/wtb 26 Power Quality Analyzers For more information, go to www.fluke.com/pq Fluke 430 Series Three-Phase Power Quality Analyzers Pinpoint power problems faster, safer and in greater detail The Fluke 435 and 434 Three-Phase Power Quality Analyzers help you locate, predict, prevent and troubleshoot problems in three- and single-phase power distribution systems. Troubleshooting is faster with on-screen display of trends and captured events, even while background recording continues. • Logged data analysis: PowerLog software provide download, analysis reporting in minutes • AutoTrend: Every measurement you see is always automatically recorded, without any setup • Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard • Inrush mode: For troubleshooting nuisance circuit breaker tripping • Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals Recommended accessories I5sPQ3 i430-flex-4pk 3 pack of 5 A precision current clamps 4 pack of 3000 A flexible current probes C435 GPS430 Water-tight hard case with rollers GPS time synchronization module Resources More PQ info online at www.fluke.com/pq Get a free PQ training DVD www.fluke.com/PQ-DVD Sign up for a PQ seminar www/fluke.com/FPQseminar • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools—even while background recording continues • Measure all three phases and neutral: With included four current probes • System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard What’s included Features Features 435 434* Measures voltage, current, dips, swells, interruptions, harmonics, inter-harmonics, flicker, power, energy, transients, frequency, unbalance, inrush, EN50160 overview • • Logger function with multi-parameter logging • Optional* Mains signaling • Optional* 16 MB 8 MB Current probes 3000 A flexible (4) 40 A/400 A clamp (4) Carrying case Water-tight hard case with rollers Rugged hard case Software Fluke Power Log and FlukeView® FlukeView® • • Memory size Three-year warranty Fluke 435 *Optional functionality can be added with upgrade kit. Ordering information (basic versions do not include current probes) Included accessories Models Four flexible current probes (i430 Flex), five test leads and clips, battery charger, FlukeView software, Power Log software, optical USB cable, color localization set, hard carrying case with rollers, getting started manual, users manual on CD. FLUKE-435 Three-Phase Power Quality Analyzer Four current probes (i400s), five test leads and clips, battery charger, FlukeView software, optical USB cable, color localization set, hard carrying case, getting started manual, users manual on CD. FLUKE-434 Three-Phase Power Quality Analyzer Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/pq Power Quality Analyzers 27 Fluke 43B Power Quality Analyzer Power quality analysis plus a scope and a meter Fluke 43B Power Quality Analyzer performs the surements you need to maintain power systems, bleshoot power problems, and diagnose equipment ures. The 43B has 20 storage locations and can store as well as screens. asic measurements: Voltage, current, and power armonics up to 51st, THD scillioscope function: View voltage and current waveforms ransients: Capture up to 40 voltage transients and waveform events etailed event capture: Cursors give time and date of ags and swells lukeView® software: Analysis and reporting, supplied with USB connection lead attery operated: 6.5 hours of operation from NiMH attery Warranty: Three-years for analyzer, one-year for ccessories Application tip The high speed oscilloscope capability is particular useful for service and commission of electronic switching loads. The wide band scope can display the details of PWM drives waveforms. Fluke Norma 4000 and 5000 Precision Power Analyzers Fluke Norma 4000 and 5000 are ideal for field and laboratory testing Fluke Norma 4000 Fluke Norma Analyzers offer easy and straight-forward operation with unmatched price performance. Features include: 1 to 6 power phases, 5.7 in/144 mm color display, harmonic analysis, scope mode, vector diagram display, recorder function, Fluke NormaView PC software and 4 MB RAM data memory. • Choose the right model for your application: a variety of standard configurations allows users to choose the exact functionality required for their unique application • Electrical measurement integrity and safety: inputs are galvanically isolated to avoid short circuits in all applications and simultaneous parallel acquisition of all phases allows accurate viewing of dynamic events dc to 3 MHz/10 MHz bandwidth for reliable measurement precision • Voltage, current and power harmonics FFT analysis: to the 40th harmonic, vector diagram, and Digital Oscilloscope (DSO) mode included in the base unit for complete analysis capability • Complete electrical and mechanical analysis: PI1 process interface to measure torque and speed with external sensors, plus four analog outputs for easy use on motor and drive applications • Data download, analysis and report writing with: supplied Fluke NormaView PC software The inrush screen shows the effects of load start up. Recommended accessories i2000 FLEX 32 A AC Current Clamp See page 60 Planar Shunt (Norma 4000/5000) i5s 100 A AC Current Clamp Shunt with Cables (Norma 4000/5000) Fluke Norma 5000 Ordering information 28 (basic versions do not include current probes) Included accessories Models Voltage and current probes, FlukeView® software, power quality instructional CD, USB interface cable, line voltage adapter/ battery charger, hard case, users manuals. FLUKE-43B Power Quality Analyzer Power supply cable, NormaView PC software, test certificate, calibration values, users manual. Norma 4000 High Precision Power Analyzer Norma 5000 High Precision Power Analyzer Power Quality Analyzers 80TK 150 A Thermocouple Module See page 59 Shunt with Cables (Norma 4000/5000) Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/pq Fluke 1735 Three-Phase Power Logger General power quality logging • • • • The Fluke 1735 Three-Phase Power Logger is the ideal electrician or technician’s tool for conducting energy studies and basic power quality logging. Set up the 1735 in seconds, with the included flexible current probes and color display. The 1735 logs most electrical power parameters and harmonics and captures voltage events. • Ideal for field operation: Compact, rugged instrument; easy to use, quickly confirm instrument setup with color display of waveforms and trends • Full system electrical measurement capability: Three phases and neutral with included four flexible current probes Prove the benefit of efficiency improvements: Record power and associated parameters for up to 45 days. Monitor maximum power demand over user-defined averaging periods Check the power quality effects energy saving devices: Measure harmonics and distortion caused by loads and improve reliability by capturing voltage dips and swells from load switching Easy PC connectivity and operation: USB interface for plug and play operation; download, view graphs and automatically generate reports with included Power Log software Reliable operation: Two-year warranty Fluke VR1710 Power Quality Recorder Application tip The Fluke 1735 provides the important data for electrical energy surveys. Detailed power information enables load balancing. Supplied PowerLog software enables detailed energy analysis. Detect and record voltage quality problems • Fast and easy recording of voltage trends, dropouts, and power quality: easily pinpoint the root cause of single phase voltage problems • Extremely easy to use: plugs directly into the mains power socket and capture data • Continuous recording of all values with no gaps: save testing time by getting the whole picture with one instrument that records both events and voltage • Clear graphical summary of data and quick overview of key power quality parameters: Take the guesswork out of diagnosing voltage quality problems • Quickly see what happened and when: Min, Max, and Average RMS values (1/4 cycle) with time stamp, transient display (>100 μs) with time stamp • Easily identify problems: Power quality or equipment related Flicker recording to EN 61000-4-15, individual harmonic and THD values with trends • Statistical analysis of single phase voltage events: Reduces analysis time by tracking event quantities and magnitudes • Includes PowerLog software: For quick download, analysis, and automatic reporting • Save time: Generate power quality reports automatically with pre-set templates • New: Transient sensitivity setting What’s included Fluke 1735 Fluke VR1710 Check fluke.com support area for firmware and software upgrades for Fluke power quality products. Ordering information Included accessories Models Four flexible current probes (15 A/150 A/3000 A), Power Log software, voltage leads and clips, color localization set, PC interface cable, international ac adapter (115 V/230 V, 50 Hz/60 Hz), soft carrying case, users manual and multi-language manual CD. FLUKE-1735 USB cable, Power Log software CD, universal power cord adapters. FLUKE-VR1710 For more information, go to www.fluke.com/pq Three-Phase Power Logger Voltage Quality Recorder Check price and availability at www.fluke.com/wtb Power Quality Analyzers 29 Fluke 1750 Three-Phase Power Recorder Never miss capturing a disturbance • Power quality that meets the standard: All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc. • Quick and reliable configuration: PDA wireless “front panel interface” provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations • Threshold-free set up: Apply thresholds after data is collected with Fluke Power Analyze Software—no need to worry about missed information due to incorrect setups • Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time • Intuitive PC software: Easily analyze data and generate reports with automated EN50160 reporting and compliance • Measure every parameter: Voltage and current on three phases, neutral, and ground Fluke 1740 Series Three-Phase PQ Loggers Memobox 1743 The Fluke 1740 Series Three-Phase Power Quality Loggers are instruments for technicians who troubleshoot and analyze power distribution systems. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard. • Plug and play: Setup in minutes with automatic current probe detection and powering • Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces, next to live power • Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables • Measure voltage with premium accuracy: IEC610004-30 Class-A compliant voltage accuracy (0.1 %) What’s included Fluke 1750 Sample PDA screens Configurations are simple with wiring diagrams to guide you. View measurements real-time with wireless PDA interface. Online resources Learn how to do what you need to do, using Fluke power quality tools. Specifications Features 1743/1744 1745 1750 Measures common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD • • • Measures voltage and current harmonics to the 50th, unbalance, and mains signaling • • • Transient capture • PDA support • Go to: www.fluke.com/pqtraining ng Product demo: www.fluke.com/1750 GPS clock synchronization UPS ride through Dimensions 3s >5 hours 5 min per interruption, 60 min total 170 mm x 125 mm x 55 mm 282 mm x 216 mm x 74 mm 215 mm x 310 mm x 35 mm (6.9 in x 5.1 in x 2.2 in) (11.5 in x 8.8 in x 3 in) (8.5 in x 12.2 in x 3.5 in) Weight (approx.) 0.9 kg (2 lb) 1.4 kg (3 lb) 6.3 kg (14 lb) Ordering information Included accessories Models Acquisition unit, PDA and charger, power plug adapters, four 400 A current probes, five test leads and clips, SD memory card, Fluke Power View and Fluke Power Analyze software, power cord with international plug set, ethernet cable, color localization set, users manual and CD. FLUKE-1750 Three-Phase Power Recorder Four flexible probes 15/ 150/1500/3000 A with 2 m cable, PQ Log software, RS-232 interface cable and USB adapter, four dolphin clips, test leads for voltages and power supply, color localization kit, carrying bag, test certificate with measurement values, users manual, multi-language manual CD. FLUKE-1745 Power Quality Logger – Memobox FLUKE-1744 Power Quality Logger – Memobox FLUKE-1743 Power Quality Logger – Memobox Power Quality Analyzers Application notes: www.fluke.com/pqappnotes Hands-on seminars: www.fluke.com/pqtrngseminars In the U.S., these power quality recorders are sold exclusively through power quality representatives. To request a demonstration, or to order, call 1-888-257-9897 or email questions to fpqsupport@fluke.com. 30 Online training: www.fluke.com/pqonlinetraining Product information: www.fluke.com/pqproducts Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/pq Pick the right process tool for you Process Tools Selection Guide Models Loop Calibrator Pressure Calibrator Temperature Calibrator Precision Multifunction Process Calibrator Intrinsically Safe Calibrator Documenting Process Calibrator 789 715 719 724 726 725Ex 744 1000 V 25 V 30 V 30 V 30 V 300 V 3200 1 4000 1 3200 1 11 k1 24 mA 24 mA 24 mA 110 mA 15 kHz 10 kHz 50 kHz •1 •5 •1 Process mA Clamp Meter ProcessMeter® Test Tool 773 30 V Measure V dc V ac (true-rms) 1000 V Resistance 40 M1 A dc 20.99, 99.9 mA 30 mA, 1 A 300 V 24 mA 24 mA • A ac Frequency 20 kHz Pressure 1 psi, 30 psi, 100 psi and 300 psi2 Temperature: RTDs 7 types 8 types 7 types 8 types Temperature: TCs 12 types 13 types 12 types 13 types Source/Simulate V dc 10 V 20 V Resistance mA dc mA source; auto step, auto ramp 24 mA 24 mA 24 mA 24 mA • • • • 10 V 20 V 10 V 15 V 3200 1 4000 1 3200 1 11 k1 24 mA 24 mA 22 mA Frequency • • • 15 kHz 10 kHz 50 kHz Temperature: RTDs 7 types 8 types 7 types 8 types Temperature: TCs 12 types 13 types 12 types 13 types Record Min/Max Hold • • • • • • • As found/As left results • Log data • • Upload data to PC • Remote operation • Features 24 V loop supply • Non-contact mA measurement • • • • • • 12 V • HART communication Integrated hand pressure pump Electric • Intrinsically safe (ATEX) Warranty Three-year Three-year Three-year • • A/B A/B C • • • 33 34 38 37 36 39 35 NIST traceable certification Accessories3 Pressure enabled4 See page • One-year Three-year Three-year Three-year Three-year • • • • A/B A/B • 32 1Fluke 700 Pressure Modules required. the internal sensor or a Fluke 700 Pressure Module may be used. 3Accessories: A. Compatible with LockPak B. Compatible with TPAK C. Accepts hanging straps from TPAK D. Optional accessories. 4Fluke Process Calibrators in this guide displaying the Pressure Enabled symbol display readings from the 700 Series Pressure Modules. 5Fluke 700PEx Pressure Module required. 2Either Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/processtools Process Calibration Tools 31 Fluke 771, 772 and 773 mA Process Clamp Meters Use the Fluke 771, 772 and 773 to: • Measure 4-20 mA signals without ”breaking the loop,” save time and money troubleshooting 4-20 mA signals Use the Fluke 772 and 773 to: Fluke 771 Fluke 772 • Source 4-20 mA signals for testing control system I/O or I/Ps • Simulate 4-20 mA signals for testing control system I/O • Measure 4-20 mA signals with in-circuit measurement • Power a transmitter with the 24 V loop power supply • Automatically ramp and step change the 4-20 mA output for remote testing Fluke 773 Resources More info online at www.fluke.com/processtools Check out the 773 video at www.fluke.com/773 ROI calculator: www.fluke.com/77X_ROI Use the Fluke 773 to: N10140 • DC voltage measurement to verify 24 V power supplies or voltage I/O signals • Source dc voltage to test voltage input devices • Scaled mA output signal enables a logging DMM (289) to record 4-20 mA signal without breaking the loop • mA in/out: simultaneously source a mA signal while measuring a mA signal with the clamp All the information you need at www.fluke.com/processsolutions Features mA measure In circuit mA source mA sim Loop power 24 V 771 mA measure w/jaw • 772 • • • • • 773 • • • • • DCV source 0-10 V DCV measure 0-30 V Scaled mA output to mA input mA in/out • • • • Specifications Function Resolution and range Accuracy Notes 0 to 20.99 mA 0.2 % + 5 counts Measured by clamp 21.0 mA to 100.0 mA 1 % + 5 counts 0 to 24.00 mA 0.2 % + 2 counts Measured in series with test jacks mA source 0 to 24.00 mA 0.2 % + 2 counts Maximum mA drive: 24 mA into 1,000 ohms 772 and 773 mA simulate 0 to 24.00 mA 0.2 % + 2 counts Maximum voltage 50 V dc 773 Voltage source 0 to 10.00 V dc 0.2 % + 2 counts 2 mA maximum drive current 773 Voltage measure 0 to 30.00 V dc 0.2 % + 2 counts 771, 772, 773 mA measurement 772 and 773 mA measurement 772 and 773 General specifications Battery 771 772 2 1.5 V, Alkaline, IEC LR6 773 20 hours typical 12 hours @ 12 mA source into 500 ohms 41.3 mm x 76 mm x 248 mm (1.625 in x 3 in x 9.75 in) Weight 260 g (9.1 oz) 415 g (14 oz) Operating temperature -10 °C to 50 ºC Size (HxWxL) With the 77X family of millamp clamp meters you can measure 4 to 20 mA I/O signals without “breaking the loop”. Once a bad signal is found the sourcing functions of the 772 and 773 can be used to further troubleshoot the loop. 4 59 mm x 38 mm x 212 mm (2.32 in x 1.5 in x 8.35 in) Working hours Application tip IP rating IP 40 Warranty Three-year, one-year on mA clamp assembly and cable Ordering information 32 Included accessories Models Soft carrying case, users manual. FLUKE-771 Milliamp Process Clamp Meter Test leads, alligator clips and hanging strap, soft carrying case, users manual. FLUKE-772 Milliamp Process Clamp Meter FLUKE-773 Milliamp Process Clamp Meter Process Calibration Tools Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/771 Fluke 789 and 787 ProcessMeter ™ Test Tools Fluke 789 ProcessMeter With the Fluke 789 ProcessMeter, process technicians an do a lot more while carrying a lot less. 24 V loop power supply HART mode setting with loop power (adds 250 ohm resistor) Double-sized, dual display 20 mA drive into 1200 ohms Backlight with two brightness settings 0 % to 100 % mA Span Check buttons to toggle between 4-20 mA Infrared I/O serial port compatible with FlukeView® Forms Software Improved battery power with four AA batteries Plus all the proven 787 features Simultaneous mA and % of scale readout on mA output 25 % Manual Step plus Auto Step and Auto Ramp on mA output Min/Max/Average/Hold/ Relative modes Externally accessible battery for easy changes IEC 1010-1 600V CAT IV Check out our latest videos at www.fluke.com/ptoolsvideos Increase your skills at www/fluke.com/processtraining Fluke 787 ProcessMeter Designed and Conforms to Resources More info online at www.fluke.com/processtools All the information you need at www.fluke.com/processsolutions True RMS (Fluke 789 only) Fluke 787 Specifications Recommended accessories Measurement function Best accuracy range and resolution (% of reading + LSD) V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.1 % + 1 V dc (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7 % + 2 mA dc 30.000 mA .05 % + 2 A dc 1.000 A (0.440 A continuous) 0.2 % + 2 A ac 1.000 A (0.440 A continuous) Resistance 400.0 1, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M 1%+2 Frequency (0.5 Hz to 20 kHz) 199.99 Hz, 1999.9 Hz, 19.999 kHz Diode test 789: 2.000 V (shows diode voltage drop) 787: 2.400 V (shows diode voltage drop) Continuity Beeps for resistance < approx. 100 ohms Output function Range and resolution DC current output (internal battery operation) 0.2 % + 1 .005 % + 1 2%+12%+1 Drive capability Accuracy (% of span) 0.000 mA to 20.000 mA or 4.000 mA to 20.000 mA (selectable at power-up) Over-range to 24.000 mA 789: 24 V compliance or, 1,200 ohms, @ 20 mA 787: 12 V compliance or, 500 ohms, @ 20 mA .05 % DC current simulate (external 0.000 mA to 20.000 mA or 4.000 mA to 20.000 mA, 24 V loop supply, up to 48 V on (selectable at power-up) Over-range to 24.000 mA 789 only) 1000 ohms, @ 20 mA .05 % 250 ohms @ 20 mA > 24 V 24 V loop supply 789: Minimum 24 V 787: Not available Current adjustment modes Manual: Coarse, Fine, 25 % and 100 % step (100 % step 789 only) Automatic: slow ramp, fast ramp, 25 % step TPAK TL220 Magnetic Meter Hanger See page 62 SureGrip Industrial Test Lead Set See page 55 80T-150U PV350 Universal Temperature Probe See page 59 Pressure Vacuum Module See page 63 Temperature range of 18 °C to 28 °C, for one year after calibration. Maximum voltage applied between any jack and earth ground:1000 V rms. Storage temperature: -40 °C to 60 °C. Operating temperature: -20 °C to 55 °C. Relative humidity: 95 % up to 30 °C; 75 % up to 40 °C; 45 % up to 50 °C; 35 % up to 55 °C. Safety: Designed in accordance with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Over-voltage CAT III. Size (HxWxL)/weight (787 with holster): 52 mm x 98 mm x 201 mm (2.06 in x 3.86 in x 7.93 in)/638 g (1.4 lb). Size (HxWxL)/weight (789): 50 mm x 100 mm x 203 mm (1.97 in x 3.94 in x 8.00 in)/600 g (1.3 lb). Warranty: Three-year. Ordering information Included accessories Models Test leads, alligator clips, 4 AA alkaline batteries (installed), quick referr ence guide, users manual, multi-language manual CD. FLUKE-789 ProcessMeter Test leads, alligator clips, holster with test lead storage, one 9 V alkaline battery (installed), quick reference guide, users manual, multi-language manual CD. FLUKE-787 ProcessMeter For more information, go to www.fluke.com/processmeters Check price and availability at www.fluke.com/wtb Process Calibration Tools 33 Fluke 715, 707 and 705 Loop Calibrators Complete family of volt/mA calibrators ke 715 Volt/mA Calibrator urce voltage to 200 mV or 20 V asure loop current (0 to 20 mA, 4 to 20 mA) signals th 0.01 % accuracy and 1 µA resolution asure voltage output process signals from PLCs, nsmitters urce or simulate 4-20 mA loop current V loop supply with simultaneous current asurement mp and Step Ramp output functions Specialty models Fluke 707 Ex Intrinsically Safe Loop Calibrator See page 39 for more information. ke 707 and 705 novative output adjustment dial on 707 provides A and 100 µA resolution and one-hand operation rge display and simple interface for ease of use multaneous mA and % readout for quick, easy erpretation of readings A accuracy of 0.015 % on the Fluke 7 and 0.02 % on the 705 RT™ mode on 707 connects 250 m resistor in series with 24 V p for compatibility with HART mmunicators sh button 25 % steps for fast, easy earity checks pan Check” for fast confirmation of o and span Selectable slow and fast linear step ramp provide ramping outputs for valve slewing, remote testing and loop functional tests Fluke 707 • 24 V internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM • 0-20 mA or 4-20 mA default start up modes Resources More info online at www.fluke.com/processtools Check out our latest videos at www.fluke.com/ptoolsvideos All the information you need at www.fluke.com/processsolutions Specifications Functions Fluke 705 and 707 Fluke 715 Voltage measurement Range Resolution Accuracy 0 V to 28 V 0 mV to 200 mV 0 V to 25 V 1 mV 10 µV 1 mV 705: 0.025 % Rdg + 1 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD 0 mA to 24 mA 0 mA to 24 mA Recommended accessories Current measurement Range Resolution Accuracy 0.001 mA 0.001 mA 705: 0.02 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % + 2 LSD Current sourcing Range Accuracy Drive capability 0 mA to 20 mA or 4 mA to 20 mA 0 mA to 20 mA or 4 mA to 20 mA 705: 0.025 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD 705: 1000 1 @ 24 mA 707: 1200 1 @ 24 mA 707Ex: 700 1 @ 20 mA 1000 1 @ 24 mA 1 Loop power while measuring mA 24 V 24 V TL28A TL220 Heavy Duty Test Lead Set SureGrip Industrial Test Lead Set See page 55 0 mV to 200 mV or 0 V to 20 V Voltage sourcing Display current and % of span Yes mA or % Auto step, auto ramp Yes Yes Span Check Yes Yes Battery life 18 hours typical, at 12 mA 18 hours typical, at 12 mA Warranty Three-year Will over-range to 24 mA. Ordering information Included accessories Models Test leads, alligator clips, holster with test lead storage, NIST-traceable calibration report and data, single 9 V alkaline battery, instruction sheet (14 languages). FLUKE-715 Volt/mA Calibrator FLUKE-707 Loop Calibrator FLUKE-707 Ex Intrinsically Safe Loop Calibrator FLUKE-705 Loop Calibrator C550 PV350 Tool Bag See page 54 Pressure Vacuum Module See page 63 Check price and availability at www.fluke.com/wtb 34 Process Calibration Tools For more information, go to www.fluke.com/loop Fluke 741B, 743B and 744 Calibrators Calibrate/troubleshoot process control instrumentation alibrate temperature, pressure, voltage, current, sistance and frequency instruments uilt-in procedures for transmitters, square root ansmitters, pressure and temperature switches multaneously measure and source utomatically capture calibration results ocument procedures and results to meet ISO 000, EPA, FDA, OSHA, and other government quirements easure/simulate 13 types of thermocouples and ght RTDs ore up to 8,000 readings in data logging mode 43B and 744 only) otected against dirt, dust and moisture; unafcted by vibration cludes a PC interface (743B and 744 only) perate in English, French, German, Italian and panish ne- and two-year calibration cycles and a ree-year warranty (one-year for pressure odules) 4: Get HART-ability Fluke 744 offers all of the capabilities of the B, plus the ability to calibrate, maintain, and bleshoot HART instrumentation. Integrated HART communication functions permit you to monitor, control, and calibrate HART instrumentation. It handles fast pulsed instruments such as RTD transmitters and PLCs, with pulses as short as 1 ms. See www.fluke.com/744upgrade for the latest list of HART instruments. Pressure Enabled Recommended software Instrumentation management software The Fluke 743B and 744 are compatible with Fluke 700SW DPC/TRACK software and with software from Cornerstone, Emerson, Honeywell, On Time Support, Prime Technologies, Yokogowa, Intools, Meridium and Beamex. For more information, visit www.fluke.com/software Resources More info online at www.fluke.com/processtools All the information you need at www.fluke.com/processsolutions www.fluke.com/ptoolsvideos 741B: A complete documenting calibrator The 741B is the economical choice for plants that don’t use PCs or that require traditional paper forms. It has storage capacity for a day’s calibration and measurement data. When you’re back at the shop, recall the data on-screen to fill out calibration forms. 743B: More memory, plus a PC interface and data logging The 743B has all the capabilities of the 741B plus a PC interface that lets you load procedures, lists, and instructions created with software—or unload data for printing, archiving, and analysis. With its expanded memory, the 743B can hold a full week of calibrations and procedures. Recommended accessories Fluke 743B Specifications Functions Measure Sourcing DC voltage 0.025 % reading + 0.005 % full scale 0.01 % output + 0.005 % full scale DC current 0.01 % reading + 0.015 % full scale 0.01 % output + 0.015 % full scale Resistance 0.05 % reading + 50 mΩ 0.01 % output + 40 mΩ Frequency 0.05 % 0.01 % Thermocouples 0.3 °C 0.2 °C RTDs 0.3 °C 0.1 °C Pressure Summary specifications: best case, mid-range, one year. Battery life: Typically over eight hours Internal battery pack: NiMH 3500 mAh Battery replacement: Via snap-shut door without opening calibrator; no tools required Weight: 1.4 kg (3 lb, 1 oz) Size (HxWxD): 236 mm x 130 mm x 61 mm (9.3 in x 5.1 in x 2.4 in) To 0.25 % of full scale, per pressure module specifications 700P 700Pxx 80PK-25 Pressure Modules See page 38 SureGrip Piercing Temperature Probe See page 58 700PTP-1 C789 Pneumatic Test Pump See page 59 Meter and Accessory Case See page 54 Ordering information Included accessories Models Industrial test leads (2 sets), test clips (2 sets), test probes, NiMH battery pack, battery charger, serial port cable, DPC/TRACK sample version with free PC communication utility software, HART communications cable, HART user’s manual, NIST traceable calibration certificate and data, instruction manual. FLUKE-744 Industrial test leads (2 sets), test clips (2 sets), test probes, battery pack, battery charger, serial port cable (743B only), DPC/TRACK sample version with free PC communication utility software (743B only), NIST traceable calibration certificate and data, instruction manual. FLUKE-743B Documenting Process Calibrator FLUKE-741B Documenting Process Calibrator FLUKE-700S DPC/Track Software For more information, go to www.fluke.com/740 Documenting Process Calibrator Check price and availability at www.fluke.com/wtb Process Calibration Tools 35 Fluke 726 and 725 Multifunction Process Calibrators luke 726 Precision Multifunction Process Calibrator he Fluke 726 measures and sources almost all proess parameters and can calibrate almost anything. nterpret results without the help of a calculator and tore measurement data for later analysis. Precise measurement and calibration source performance, accuracies of 0.01 % Transmitter error% calculation, interpret calibration results without a calculator Memory storage for up to eight calibration results, return stored calibration data from the field for later analysis Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation Integrated pressure switch test allows you to capture the set, reset and deadband of a switch Custom RTD curves, add calibration constants for certified RTD probes for temperature measurement Voltage input protection design for improved reliability Fluke 725 Multifunction Process Calibrator Pressure Enabled • Measure volts, mA, RTDs, thermocouples, frequency and ohms to test sensors and transmitters • Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms and pressure to calibrate transmitters • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules • Source mA with simultaneous pressure measurement to conduct valve and I/P tests • Support flow meter testing with frequency and counts per minute (CPM) functions • Perform fast linearity tests with auto step and auto ramp features Take the 725 virtual demo tour at www.fluke.com/725demo Specifications Measure and source Functions Range or type Resolution Accuracy Notes Voltage 0 to 100 mV 0 to 10 V (source) 0 to 20 V (source) 0 to 30 V (measure) 0.01 0.01 0.01 0.01 0.01 %, 0.02 % Rdg + 2 LSD Max load, 1 mA mA 0 to 24 0.001 mA 0.01 %, 0.02 % Rdg + 2 LSD Max load, 1000 1 mV (TC terminals) -10.00 mV to +75.00 mV .01 mV 0.01 %, 0.02 % of range + 1 LSD Ohms 15 1 to 3,200 1 5 1 to 4,000 1 0.01 1 to 0.1 1 0.10 1 to 1.0 1 0.015 % Hz - CPM 2.0 to 1,000 CPM 1 to 1000 Hz 1.0 to 10.0 kHz 10.0 to 15.0 kHz 0.1 CPM 1 Hz 0.1 kHz 0.1 kHz ± ± ± ± Loop supply 24 V dc N/A 10 % T/C J, K, T, E, L, N, U, XK 0.1 °C, 0.1 °F to 0.7 °C to 0.2 °C T/C B, R, S, BP 1 °C, 1 °F to 1.7 °C to 1.2 °C RTDs Cu (10), Ni120 (672) Pt 100, 200, 500, 1000 (385) Pt 100 (3916), Pt 100 (3926) 0.01 °C, 0.01 °F to 0.15 °C 0.1 °C, 0.1 °F to 0.2 °C mV V V V 0.05 % 0.05 % 0.25 % 0.05 % Source; 5 V p-p 1 V to 20 V p-p squarewave, -0.1 V offset General specifications Storage temperature: -20 °C to 71 °C Operating temperature: -10 °C to 55 °C Relative humidity: 90 % (10 °C to 30 °C); 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C); 35 % (50 °C to 55 °C) Shock: 1 meter drop test Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022:1994 Class B Size (HxWxD): 200 mm x 96 mm x 47 mm (7.9 in x 3.8 in x 1.9 in) Weight: 650 g (23 oz) Battery: Four AA alkaline batteries Battery life: 25 hours typical Warranty: Three-years Intrinsically safe version available (see page 39) Recommended accessories Unique 726 specifications are bolded. Simultaneous function capability Channel A Channel B 24.000 mA dc M M or S 24.000 mA dc with 24 V loop supply M 100.00 mV dc M or S 30.000 V dc measure TPAK 80PK-27 Magnetic Meter Hanger See page 62 Industrial Surface Temperature Probe See page 58 M 20.000 V dc measure; 10.000 V dc source; 20.000 V dc source M or S 15 to 3200 Ohms (725); 5 to 4000 Ohms (726) M or S Thermocouple J, K, T, E, R, S, B, M, L, U, N, XK, BP M or S RTD Cu 10, Ni120; Pt100 (392); Pt100 (JIS); Pt100, 200, 500, 1000 (385), XK and BP Pressure (requires Fluke 700PXX Modules) M or S M Frequency; 10 kHz; (15 KHz 726) M used as S M or S M = Measure, S = Source/Simulate 700Pxx C125 Pressure Modules See page 38 Soft Carrying Case Ordering information 36 Included accessories Models Test leads, test clips, one pair of stackable test leads, product overview manual, users manual in 14 languages on CD. FLUKE-726 Precision Multifunction Process Calibrator FLUKE-726 Ex Intrinsically Safe Precision Multifunction Process Calibrator FLUKE-725 Multifunction Process Calibrator Process Calibration Tools Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/726 Fluke 712, 714 and 724 Temperature Calibrators The Fluke 710 Series temperature calibrators deliver outstanding performance, durability and reliability. And with a push-button interface, similar to the multifunction Fluke 740 Series Documenting Process Calibrators, the 710 Series are easy to use. Each calibrator is EMI tolerant, dust- and splash-resistant, and features a removable battery door for quick battery changes. Fluke 714 Thermocouple Calibrator • • • • • • • • Measure temperature from TC probes Simulate TC output Operable with nine types of thermocouples Calibrate linear TC transmitter with mV source function Selectable °F or °C 25 % stepping, auto-step and auto-ramp Available as accessories: Fluke 700TC1 and TC2 Thermocouple Mini-plug Kits Ramp and Step Ramp output functions Fluke 712 RTD Calibrator • Compatible with pulsed current transmitters • Measure temperature from an RTD probe • Simulate RTD output • Operates with seven types of RTD • Measure additional RTDs using ohms measurement function • Simulate additional RTDs using ohms source function • °F or °C selectable • 25 % stepping, auto-step and auto-ramp • Ramp and Step Ramp output functions Specialty model Fluke 724 Temperature Calibrator • Source/measure TCs, RTDs, volts and ohms • Measure mA while supplying loop power • 25 % and 100 % stepping, autostep and auto ramp Resources Information for the classroom at www.fluke.com/education Recommended accessories TL75 (712/724) TL220 (712/724) Hard Point Test Lead Set See page 57 SureGrip Industrial Test Lead Set See page 55 80PK-24 (714/724) 80PK-3A (712/724) SureGrip Air Temperature Probe See page 58 Surface Probe See page 58 Specifications Models Functions Range Resolution Accuracy Notes Measure/simulate RTD -200 °C to 800 °C (Pt 100-385) 0.1 °C, 0.1 °F 0.2 °C, 0.4 °F (Pt 100-385) Pt; 100 200 500 1000 (385); Pt 100 (392); Pt 100 (392) JIS; Ni 120 (672) Measure/simulate resistance 5 1 to 4000 1 0.1 1 0.025 % Measure/simulate thermocouple -200 °C to 1800 °C, depending on type (K, -200 °C to 1370 °C) 0.1 °C or °F (1 °C or °F; BRS) 0.5 °C, 0.8 °F (Type K) Measure/simulate mV -10 mV to 75 mV 0.01 mV 0.015 % +10 µV Fluke 712 Fluke 714 9 TC types; J K T E R S B per NIST 175 and ITS-90 L U per DIN 43710 and PTS-68 Maximum voltage: 30 V. Non-operating temperature: -40 °C to 60 °C. Operating temperature: -10 °C to 55 °C. Relative humidity: 95 % (10 °C to 30 °C); 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C); 35 % (50 °C to 55 °C). Operating altitude: 3,000 m max. Shock: 1 m drop test. Vibration: Random, 2 g, 5-500 Hz. Safety: CSA C22.2 No. 1010.1:1992. EMC: EN50082-1:1992 and EN55022:1994 Class B. Size/weight (HxWxD) (712-717): 187 mm x 87 mm x 32 mm (7.35 in x 3.41 in x 1.25 in) 330 g (12 oz). Size/weight (HxWxD) (712-717 with holster): 201 mm x 98 mm x 52 mm (7.93 in x 3.86 in x 2.06 in) 600 g (21 oz). Size/weight (HxWxD) (718): 210 mm x 83 mm x 62 mm (8.25 in x 3.27 in x 2.44 in) 737 g (26 oz). Size/weight (HxWxD) (718 with holster): 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in) 992 g (35 oz). Power: 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 . Battery life: 4 to 20 hours, typical, depending on functions used. Warranty: Three-year (one-year on pressure pump in Fluke 718). TPAK AC220 Magnetic Meter Hanger See page 62 SureGrip Alligator Clips See page 57 C101 (724) C25 (712/714) Meter Hard Case See page 54 Large Soft Case See page 54 Ordering information Included accessories Models Test leads, test clips, one pair of stackable test leads, product overview manual, users manual in 14 languages on CD. FLUKE-724 Temperature Calibrator Test leads, alligator clips (excluding model 714), holster with test lead storage, single 9 V alkaline battery and instruction sheet (14 languages). FLUKE-714 Themocouple Calibrator FLUKE-712 RTD Calibrator Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/tempcal Process Calibration Tools 37 Fluke 717, 718 and 719 Pressure Calibrators Accurate and rugged, temperature calibration tools Fluke 719 Electric Pressure Calibrators • Electric pump enables one handed pressure pumping and makes pressure calibration quicker and easier • Best in class 0.025 % pressure measurement accuracy • Programmable pump limit settings can eliminate overpressurization—set ‘pump to’ pressure values • Two ranges, 30 PSI and 100 PSI Fluke 718 Pressure Calibrators • 1, 30, 100 and 300 PSI ranges available • Pump to 300 PSI, 20 bar with internal pump (718-300G) • 718-1G includes special low volume pump and high measurement resolution for low pressure calibration Fluke 717 Pressure Calibrators • Measure up to 5000 PSI/345 bar sensor (5000G model) • Compatible with non-corrosive gases and liquids 718 and 719 Fluke 719 Fluke 700 Series Pressure Modules • 29 pressure modules • 8 intrinsically safe pressure modules* • Ranges from 1.000 in H20 (0.2491 kPa) to 10,000 psi (68.948 MPa) • Gage, differential, dual (compound), absolute, and vacuum modules • Rugged cases protect the modules from harsh environments • Full-accuracy performance from 0 °C to 50 °C *For use with 718Ex and 725Ex only (see page 39 for more information). Fluke 718 • Precision vernier for fine pressure adjustment • Variable release rate bleed valve for controlled pressure release Pressure Enabled Specialty model Pressure Enabled 717, 718 and 719 common features Fluke Process Calibrators in this catalog displaying the Pressure Enabled symbol display readings from the 700 Series Pressure Modules. Resources • Pressure switch test makes a difficult task easy, captures set, reset and deadband values of a pressure switch • 717 and 718, measure pressure to 0.05 % of full scale with internal sensor • Measure mA with 0.015 % accuracy and 0.001 mA resolution, while sourcing 24 V loop power More info online at www.fluke.com/processtools Check out the 719 video at www.fluke.com/719video Fluke 717 Specifications Models Range Resolution Comment 717-1 +/- 1 psi, 27.5 in H20, (-7 - +7 kPa) +0.0001 psi, 0.0001 kPa, 0.0001 in H20 Fluke-718 dry air only and includes on board pump -12 to + 30 psi, (-83 to 207 kPa) 0.001 psi, 0.001 kPa, 0.001 in H20 Fluke-718 and Fluke-719 dry air only and includes on board pump -12 to + 100 psi, (-83 to 690 kPa) 0.01 psi, 0.01 kPa, 0.01 in H20 Fluke-718 and Fluke-719 dry air only and includes on board pump -12 to +300 psi, (-83 to +2070 kPa) 0.01 psi, 0.01 kPa, 0.01 in H20 Fluke-718 dry air only and includes on board pump 717-500G 0-500 psi, 0-3450 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive gases and fluids 717-1000G 0-1000 psi, 0-6900 kPa 0.01 psi, 0.1 kPa Compatible with non-corrosive gases and fluids 700ILF 700LTP-1 717-1500G 0-1500 psi, 0-10342 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids 717-3000G 0-3000 psi, 0-20700 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids In-Line Filter See page 59 Low Pressure Test Pump See page 59 717-5000G 0-5000 psi, 0-34500 kPa 0.1 psi, 1 kPa Compatible with non-corrosive gases and fluids Pressure accuracy 0.05 % of range, one year for 717 and 718. 0.025 % for six months, 0.035 % of range, one year for the 719 mA measurement 0-24 mA range Loop power 24 V dc 718-1G 717-30G 718-30G* and 719-30G 717-100G 718-100G* 717-300G 718-300G* and 719-100G 0.001 mA resolution Recommended kits Accuracy: ± 0.015 % + 1 count Accuracy: ± 10 % *Intrinsically safe models available, see page 39. Warranty: Three-year on calibrator, one-year on pump. Ordering information Included accessories Test leads, alligator clips, holster, test hose (719), one 9 V alkaline battery (two 9 V batteries in 718 and 719), safety sheet. 700HTP-1 C116 Hydraulic Test Pump See page 59 Large Soft Case See page 54 Models FLUKE-719-30G Electric Pressure Calibrator FLUKE-719-100G FLUKE-718 1G Pressure Calibrator FLUKE-718 30US Electric Pressure Calibrator Pressure Calibrator FLUKE-718 100US Pressure Calibrator FLUKE-718 300G Pressure Calibrator FLUKE-717 1G Pressure Calibrator FLUKE-717 30G Pressure Calibrator FLUKE-717 100G Pressure Calibrator FLUKE-717 300G Pressure Calibrator FLUKE-717 500G Pressure Calibrator FLUKE-717 1000G Pressure Calibrator FLUKE-717 1500G Pressure Calibrator FLUKE-717 3000G Pressure Calibrator FLUKE-717 5000G Pressure Calibrator Check price and availability at www.fluke.com/wtb For a full list of Fluke 700 Pressure Modules, visit www.fluke.com/pressure. 38 Process Calibration Tools For more information, go to www.fluke.com/pressure Intrinsically Safe Products Calibrators, thermometers and multimeters designed to intrinsic safety standards What is “Intrinsically Safe”? Intrinsic safety is a protection method employed in potentially explosive atmospheres. Devices that are certified as “intrinsically safe” are designed to be unable to release sufficient energy, by either thermal or electrical means, to cause ignition of flammable material (gas or dust/particulates). There are no global intrinsically safe standards or certifications, but there are organizations that influence directives in certain world geographies. Factory Mutual – In the United States, Factory Mutual Research, managed by Factory Mutual (FM) Global, is a non-profit scientific and testing organization that has tested and certified over 40,000 products in the last 165 years. FM Research has set certification guidelines for equipment used in potentially explosive atmospheres. Canadian Standards Association (CSA) – Accreditation body for North American regulations, based in Toronto, Canada. ATEX – The primary intrinsically safe standard, which has been set in the European Union with the Directive 94/9/EC, commonly called ATEX (“Atmosphères Explosibles”), French for explosive atmospheres. For more information and detailed specifications, turn to the corresponding non-intrinsically safe product pages (Fluke 707, 718, 725, 574, 68) or go to www.fluke.com/ex. Fluke products 87V Ex: Intrinsically Safe True-rms Multimeter ATEX certified North American Certification For additional product detail See page 12 II 2 G Ex ia IIC T4 707Ex: Intrinsically Safe mA Calibrator II 2 G Ex ia IIC T4 N.I. Class I, Div 2, Groups A-D T4 See page 34 Specialty models Fluke 68IS Intrinsically Safe Infrared Thermometer • Laser guided sighting system with 1 % accuracy • 12-point data logging • Advanced optics • Adjustable emissivity • Selectable Max/Min/Dif/Avg functions that display values instantly with Hi/Lo Alarm • Expanded measurement range up to 760 °C (1400 °F) • RTD probe accessory included • Class I, Division 1, Groups A, B, C, D Class I, Zone 0, AEx ia IIC, T4 at 50 °C when used with 9 V alkaline battery Not available for purchase in Europe. 574-NI Nonincendive Thermometer For data loading and extra safety the Fluke 574 Nonincendive (NI) Thermometer has the same great features as the 574 model thermometer with the extra confidence of a Factory Mutual approval for use in hazardous environments. Class I, Division 2, Groups A, B, C, D: Class I, Zone 2 IIC; T4 Ta=50 °C when used with 1.5 V alkaline batteries. 718Ex: Intrinsically Safe Pressure Calibrator See page 38 II 1 G Ex ia IIC T4 Groups A-D T4 Resources More info online at www.fluke.com/processtools 725Ex: Intrinsically Safe Multifunction Calibrator See page 36 II 1 G Ex ia IIB 171 °C Groups B-D, 171 °C Take a look at all the intrinsically safe models at www.fluke.com/insafety 700PEx: Intrinsically Safe Pressure Modules II 1 G Ex ia IIC T4 I.S. Class I, Div 1, Groups A-D T4 See page 38 Class I, Division 2, Groups A, B, C, D; Class I, Zone 2 IIC See page 50 Fluke 574-NI Nonincendive Infrared Thermometer All the information you need at www.fluke.com/processsolutions Fluke 68IS Intrinsically Safe Infrared Thermometer Class I, Division 1, Groups A, B, C, D Class I, Zone 0 AEx ia IIC Ordering information Models Models FLUKE-87VEx IS True-rms Multimeter FLUKE-707Ex IS Loop Calibrator FLUKE-718Ex IS Pressure Calibrator FLUKE-725Ex IS Multifuction Process Calibrator FLUKE-700PEx Pressure Modules (700P: 01, 5, 6, 9, 24, 27, 29, A4Ex) FLUKE-574-NI Precision Infrared Thermometer w/Logging SW Nonincendive FLUKE-68IS Infrared Thermometer Intrinsically Safe For more information, go to www.fluke.com/ex Check price and availability at www.fluke.com/wtb Process Calibration Tools 39 Fluke ScopeMeter® Test Tools Handheld oscilloscopes for industrial, instrumentation and electronic applications Fluke 225C TM Fluke 199C ScopeMeter test tools are the rugged, safe choice for a wide variety of field service installation and maintenance applications. These handheld battery-powered oscilloscopes tools are easy to use, with a built-in multimeter, paperless recording and analysis capabilities. They are rugged and IP 51 dust- and drip-proof rated to IEC529 standards to withstand harsh environments. The new 190 Series II, four isolated input channels and 100 MHz or 200 MHz bandwidth are ideal for industrial machinery applications measuring three-phase power electronics or three-axis control systems comparing and contrasting multiple signals simultaneously. These tools are safety, rated at CAT III 1000 V/ CAT IV 600 V with longer battery life and up-to-date USB interface technology. Fluke 124 The 190C Series, with two isolated inputs and 60 MHz, 100 MHz or 200 MHz bandwidth, is the choice for industrial electronic applications like automation and process control. These oscilloscopes are rated for CAT II 1000 V/ CAT III 600 V environments and will operate for up to four hours without a recharge. The 120 series with 20 MHz or 40 MHz bandwidth, dual DMMs and paperless recording is the optimal choice for electrical and electro-mechanical applications, safety rated to IEC EN61010-1 CAT III 600 V. For Industrial network applications, Fluke 125, 215C or 225C add industrial network physical layer analog measurement algorithms to validate the network bus health. Selection guide 120 Series 123 190C Series 124 125 • • 215C 225C 192C 190 Series II 196C 199C 190-104 190-204 Bandwidth 20 MHz • 40 MHz • 60 MHz • 100 MHz • • 200 MHz • • • Input channels 2Ch + 2 DMM • • • 2Ch + DMM • • • • • • • • • • • • • • • • • • • • • • • • • • • • 4Ch Isolated inputs Triggering Connect-and-View • • • Advanced triggering Advanced measurement function • • • • • • • • • • • • • • • • • • ScopeRecord • • • • • • • 100 screen replay • • • • • • • • • Cursors TrendPlot • Industrial bus health • Harmonics • • • • • • • • Power measurements • • • • • • • • Waveform mathematics • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • FFT EN61010-1 safety CAT II 1000 V CAT III 600 V • • • CAT III 1000 V CAT IV 600 V Interface Optical RS-232 USB PC interface • • • • • • • • Opt Opt Opt Opt Opt Opt Opt Opt USB memory port Power Ni-MH • • • • • • • • 7 7 7 4 4 4 4 4 Li-Ion Battery (hours) • • 7 7 General specifications Size (HxWxD) Weight 40 ScopeMeter Test Tools 9.2 in x 4.5 in x 2 in 10.1 in x 6.7 in x 2.5 in 10.5 in x 7.5 in x 2.8 in 2.6 lb 4.4 lb 4.8 lb For more information, go to www.fluke.com/scopemeter Fluke 123 and 124 ScopeMeter® Test Tools Three-in-one simplicity The compact ScopeMeter 123 and 124 are the rugged solution for industrial troubleshooting and installation applications. Each is a truly integrated test tool, with oscilloscope, multimeter and “paperless” recorder in one affordable, easy-to-use instrument. Find fast answers to problems in machinery, instrumentation, control and power systems. • Dual-input 40 MHz or 20 MHz digital oscilloscope • Two 5,000-count true-rms digital multimeters • A dual-input TrendPlot ™ recorder • Connect-and-View ™ trigger simplicity for hands-off operation • Shielded test leads for oscilloscope, resistance and continuity measurements • Up to seven hours battery operation • CAT III 600 V safety certified • Optically isolated RS-232 interface • IP 51 rated, rugged compact case Resources Improve your troubleshooting skills, Fluke can help! Visit the ScopeMeter Training Center: www.fluke.com/ScopeMeterTraining Center Recommended kits SCC 120 Kit • Software • Cable • Hard carrying case Connect-and-View ™ triggering for an instant, stable display Scope users know how difficult triggering can be. Incorrect settings show unstable and sometimes incorrect results. Fluke’s unique Connect-and-View recognizes signal patterns and automatically and continuously sets up correct triggering. It provides a stable, reliable and repeatable display of virtually any signal. Use TrendPlot™ to help find intermittents The toughest faults to find are those that happen only once in a while—intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. Other factors, like line outages and sags, can also cause a machine to stop. You may not be around to see it—your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time—up to 16 days. SCC 190 Kit • Software • Cable • Hard carrying case Connect-and-View captures even the most complex motor drive signals. Recommended accessories Battery powered mobility Up to seven hours of battery operation frees you from mains outlets for true on-the-move working. The rugged and drip proof case assures long life and reliable operation in the harshest industrial environments. Safety rated The ScopeMeter 123 and 124 are safety rated for measurements on CAT III 600 V rms industrial power systems with the included test leads. PAC91 i30s Printer Adapter Cable AC/DC Current Clamp See page 61 Use TrendPlot to help find intermittents, fast. C125 C195 Soft Carrying Case See page 54 Tool Bag See page 54 Ordering information Included accessories Models Test lead set, alligator clips, hook clips, battery pack, battery charger/line voltage adapter, BNC adapter, getting started guide, users manual on CD. FLUKE-124S Test lead set, alligator clips, hook clips, battery pack, battery charger/line voltage adapter, BNC adapter, OC4USB optically isolated RS-232 adapter/cable, FlukeView for ScopeMeter Windows® software, hard carrying case, getting started guide, users manual on CD. Industrial ScopeMeter, 40 MHz, with SCC120 kit FLUKE-124 Industrial ScopeMeter, 40 MHz FLUKE-123S Industrial ScopeMeter, 20 MHz, with SCC120 kit FLUKE-123 Industrial ScopeMeter, 20 MHz SCC120 Kit containing FlukeView software for Windows, USB interface adapter/cable and hard case For more information, go to www.fluke.com/scopemeter Check price and availability at www.fluke.com/wtb ScopeMeter Test Tools 41 Fluke 190 Series II ScopeMeter® Test Tools See more, fix more, in harsh industrial environments Goes where ordinary scopes can’t go Safety rated for industrial applications, the 190 Series ScopeMeter combines rugged portability with high performance to take you all the way from troubleshooting microelectronics to power electronic applications. The first high-performance four-channel scopes built for harsh industrial environments For the first time, plant maintenance engineers and technicians can take a high-performance fourchannel scope into the harsh world of industrial electronics. The new Fluke 190 Series II is the only portable oscilloscope with four independent isolated input channels, a CAT III 1000 V/CAT IV 600 V safety rating, and an IP 51 dust-proof and drip-proof rating. Both the 200 MHz (Fluke 190-204) and 100 MHz (Fluke 190-104) bandwidth models offer these capabilities: • 4 independent isolated inputs, up to 1000 V • High-speed sampling: Up to 2.5 GS/sec • Deep memory: 10,000 points per trace waveform capture • CAT III 1000 V/CAT IV 600 V safety rated for high voltage environments • Up to 7 hours of battery operation, standard • Isolated USB host port for direct data storage to a USB memory • Device, plus USB device port for easy PC communication • Easy-access battery door for quick battery swaps in the field • Compact and only 2.2 kg (4.8 lb) • Security slot: lock down oscilloscope with Kensington lock while unattended Fluke 190-204 Fluke 199C Automatic capture and replay of 100 screens Scope users know how frustrating it is to see a one-time anomaly flash by—never to be seen again. Not with the ScopeMeter 190 series. Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens, on a first in-first out basis. At any moment you can “freeze” the last 100 screens and scroll through picture-by-picture or replay as a “live” animation. Cursors can be used for further analysis. ScopeRecord mode for high-resolution waveform recording up to 48 hours ScopeRecord memory stores up to 27,000 data points per channel, capturing fast intermittents and glitches as short as 8ns. • Stores events like motion profiles, UPS, power supply and motor start-ups Sample screens Connect-and-View™ captures even the most complex motor drive signals. Use the 27,000 points memory of ScopeRecord and zoom in for maximum detail. • In Stop On Trigger mode, ScopeMeter automatically recognizes a power failure and stores the waveform data • With the waveform zoom (up to 100x) you can look at the smallest details, like individual power cycles TrendPlot Paperless Recorder The toughest faults to find are those that happen once in a while. These intermittents can be caused by bad connects, dust, dirt, corrosion, or simple broken wiring or connectors. Line outages, sags or starting and stopping of a motor can also cause a machine to stop. You may not be around when it happens, but the Fluke ScopeMeter will. • Plot minimum and maximum plot values and average over time up to 16 days • Plot any combination of voltages, amps, temperature, frequency and phase for all four inputs, all with time and date stamp to pinpoint faults Cursors and zoom features of the Fluke 190 Series help you to analyze the captured TrendPlot. Resources Go to www.fluke.com/fourchannelscopemeterr for interactive troubleshooting demonstrations. Ordering information 42 Included accessories Models Test lead set, voltage probes (200 MHz, 10:1)-red and gray, battery charger/line voltage adapter, battery pack, getting started guide, users manual on CD. FLUKE-190-204 ScopeMeter Test Tools Color ScopeMeter (200 MHz, 2.5 GS/s, 4 channel) FLUKE-190-204S Color ScopeMeter (200 MHz , 2.5 GS/s, 4 channel), with SCC290-kit FLUKE-190-104 Color ScopeMeter (100 MHz, 1.25 GS/s, 4 channel) FLUKE-190-104S Color ScopeMeter (100 MHz, 1.25 GS/s, 4 channel), with SCC290-kit FLUKE-199C Color ScopeMeter (200 MHz, 2.5 GS/s) FLUKE-199C/S Color ScopeMeter (200 MHz, 2.5 GS/s) + SCC190 FLUKE-196C Color ScopeMeter (100 MHz, 1 GS/s) FLUKE-196C/S Color ScopeMeter (100 MHz, 1 GS/s) + SCC190 FLUKE-192C Color ScopeMeter (60 MHz, 500 MS/s) FLUKE-192C/S Color ScopeMeter (60 MHz, 500 MS/s) + SCC190 kit Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/scopemeter Fluke 225C, 215C and 125 ScopeMeter® Test Tools he Fluke 225C, 215C and 125 re the instruments of choice for maintenance specialists who deal with industrial buses and networks s well as general electronics. You an verify the electrical integrity f your bus and network physical ayer, performing tests and getting nswers to digital signalling issues uickly and easily. These instruments offer all he functions found in the 120 or 90C Series, plus added measurement capabilities for industrial networks such as Profi®, Foundaion™, Modbus®, CAN-bus, AS-i bus, RS-485 and more. Bus Health physical layer appliation measures critical digital ignal amplitude, time and noise r distortion characteristics. Find errors like signal attenuation and distortion caused by improper cable connections, bad contacts, incorrect grounding, and missing or superfluous terminators. Signal integrity analysis is extended with the eye-pattern mode. A waveform display is built over successive signal passes to give you a visual indication of overall signal quality, noise levels, and signal jitter. • Critical bus physical layer amplitude, time and noise or distortion measurements • Compare measurement results to limits defined by the industry standard • Display clear “good”, “weak” or “bad” indicators. • Eye pattern mode to visually inspect waveforms quality of transmitted data packets • 215C or 225C with isolated inputs perform floating differential measurements on balanced two wire bus systems • 125 dual input measurements performed relative to common reference point • BHT190 breakout adapter set DB9, RJ45 and M12 simplify probing onto bus signal connectors Sample screens Measure critical signal characteristics, compare to industry standard. Use “eye” diagrams to inspect for issues like signal noise, distortion and other common disturbances. Recommended accessories BHT190 i30S Bus Health Test Adapter, DB-9 and M-12 AC/DC Current Clamp See page 61 Specifications Fluke 225C (200 MHz 199C) Fluke 215C (100 MHz 196C) Fluke 125 (40 MHz 124) Dual isolated inputs for differential bus system probing • On screen bus system probe connection diagrams • Bus Health AS-i Physical CAN-bus (ISO-11898) (DeviceNet) Layer Standards Interbus S (EIA-485) ControlNet (61158 type 2) • • • • i410 • AC/DC Current Clamp See page 61 • Modbus (EIA-232, EIA-485) • • Foundation Fieldbus H1 (61158 type 1) • • Profibus DP (EIA-485), PA (61158 type 1) • • Ethernet 10Base2 (coax), 10BaseT (UTP) • • Ethernet 100BaseT (100 Mb/s) • RS-232 (EIA-232), RS-485 (EIA-485) Measured parameters Eye diagram “qualitative” waveform analysis BusHealth breakout adapter set • • Bias Voltage Level, signal amplitude, pulse width or baud rate, rise/ fall time, jitter, signal distortion, noise HF, noise LF, in-band noise • Baud rate, rise/fall time, high level, low level, distortion, amplitude, jitter BHT190 included BHT190 optional Resources Go to www.fluke.com/scopemeterfaqs for answers to frequently asked questions. Ordering information Included accessories Test lead set, battery charger/line voltage adapter, battery pack (installed), getting started guide, multilingual users manual on CD. Models FLUKE-225C/003 Color ScopeMeter (200 MHz, 2.5 GS/s) with Bus Health test capabilities built-in FLUKE-225C/003S Color ScopeMeter (200 MHz, 2.5 GS/s) with Bus Health test capabilities built-in, with SCC190 kit FLUKE-215C/003 Color ScopeMeter (100 MHz, 1 GS/s) with Bus Health test capabilities built-in FLUKE-215C/003S Color ScopeMeter (100 MHz, 1 GS/s) with Bus Health test capabilities built-in, with SCC-kit FLUKE-125 Industrial ScopeMeter, Bus Health, Power & Harmonics FLUKE-125S Industrial ScopeMeter, Bus Health, Power and Harmonics with SCC-Kit For more information, go to www.fluke.com/scopemeter Check price and availability at www.fluke.com/wtb ScopeMeter Test Tools 43 Fluke Thermal Imaging Find it, fix it, fast Superior image quality Just pick up a Fluke imager and you’ll immediately see the difference. Fluke delivers the clear, crisp images needed to find and fix problems fast. • Industry leading thermal sensitivity (NETD) enables you to identify the small temperature differences that could indicate big problems • Even the smallest details become visible with the large, widescreen full VGA color LCD display • Patented IR-Fusion® Easy to use When you pick up a tool, you need it to operate and deliver results without having to read a heavy manual • Intuitive, three-button menu is easy to use… simply navigate with the push of a thumb • Add comments quickly and easily with voice annotation feature for precise image viewing control Rugged Tools are meant to be used, and Fluke thermal imagers are designed to reliably operate in the toughest environments. • Engineered and tested to withstand a 2 m (6.5 ft) drop— when was the last time you dropped a tool? See the proof at www.fluke.com/rugged • Use in ambient temperatures as low as -10 °C (14 °F) and high as +50 °C (122 °F) • Protected by two-year warranty, with one- or two-year extended warranties available Ask your Fluke representative for more details. IR-Fusion® Technology Not all fusion is created equal Infrared images alone can be difficult to understand, which is why Fluke pioneered IR-Fusion, a revolutionary marriage of visible and infrared images never before seen in commercial or industrial thermal imagers. Automatically capturing a visible image with every infrared image allows you to always know exactly what you’re looking at. Don’t be fooled by imitators. Patented IR-Fusion is the only solution with physical parallax correction, enabling the perfect alignment and smooth blending of both infrared and visible images. While many manufacturers have attempted to duplicate Fluke IR-Fusion, none have been able to match it. Turn to Fluke IR-Fusion to deliver the industry’s best thermal images. IR-Fusion viewing modes Full IR Alpha Blending Full Visible Light Application tips Electric motors and pumps Hot spots may be an early indicator of motor winding problems. Elevated temperatures can damage winding insulation, resulting in operational inefficiencies and premature motor failure. An overheated motor may be an indication of an underrated motor in the application, insufficient cooling or electrical power problems. Bus bars and fuse boxes Temperature differences between phases may indicate unbalanced loads, harmonics, component problems, bad connections or bad wiring. These conditions can result in increased energy cost and can damage cables or machines or possibly cause fire. Even small temperature differences between phases should be investigated to determine the root cause. Residential and commercial energy loss Missing or improperly installed insulation, moisture, and air leaks reveal opportunities for property owners to lower their energy costs. Save time and money by finding problems fast and ensuring repairs are done correctly. Resources To request more information, or a demonstration, or to order, call 1-800-760-4523 (U.S. only), all other regions 1-425-446-4620. Picture in Picture 44 Thermal Imaging IR/Visible Alarm Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/thermal_imaging Fluke SmartView® Software Analysis and reporting software Palette samples Fluke palette options (six of 16 available, varies by model) Amber Powerful Everything you need for analysis and reporting. • Extensive annotation, editing and viewing options with full IR-Fusion® capabilities • Multiple reporting options and templates and 3D-IR™ for unique 3D analysis Easy to use • SmartView tools and controls allow easy access to editing functions and its easy drag and drop text annotation feature • Report Wizard guides you through automatic, professional report generation Included with every imager Fluke includes SmartView software with unlimited licenses and lifetime upgrades with every thermal imager • No need to pay extra for a professional software solution SmartView® system requirements Software requirements • Windows® XP SP2/Vista/7 • A web browser for product registration and web updates • Internet Explorer 5.0 or newer • 512 MB of RAM minimum (1 GB for Vista or 7) • 360 MB of hard disk space for product installation • Microsoft® Word 2007 for report template modification (optional) Hardware requirements • Memory card reader to transfer images to computer (included) • 512 MB RAM (1GB for Vista), not including the space requirements for web browser and Microsoft® Word • 16-bit color, 1024x768 resolution video or better • CD-ROM drive for installing SmartView software Blue-red Grey Fluke Training Solutions Getting started with Fluke Ti Thermal Imagers High contrast Unsure where to begin with your new thermal imager? Don’t worry. Fluke utilizes an extensive network of industry experts to deliver a full portfolio of training solutions. • Free in-box training DVD: This convenient training solution provides a general introduction to thermal imaging, product information, and common applications. • Free online webinars: Fluke offers both pre-recorded and live webinars to meet the needs of busy professionals. Visit www.fluke.com/titraining for course listings and schedules. • Hands-on training seminars: Join us for one of our many local seminars where Fluke Thermography experts will teach basic thermography with hands-on demonstrations. Fluke authorized training Go to www.fluke.com/titraining for schedules. is provided by our partner, • Advanced training: For advanced thermography (Level I to Level III) and application specific training either online, in the classroom or at your site, sign up through Fluke authorized, independent training partners. Visit www.fluke.com/ titraining for training options and schedules. For more information, go to www.fluke.com/thermal_imaging Ironbow Hot metal Check price and availability at www.fluke.com/wtb Thermal Imaging 45 Ti Series Industrial Thermal Imagers The ultimate tools for troubleshooting and maintenance optional telephoto lens The perfect tools to add to your problem solving arsenal. Built for tough work environments, these high-performance, fully radiometric imagers are ideal for troubleshooting electrical systems, electro-mechanical equipment, process equipment, HVAC/R equipment and others. • Enhanced problem detection and analysis capabilities with patent-pending IR-Fusion® Technology—only available from Fluke • Optimized for field use in harsh work environments – Engineered and tested to withstand a 2 m (6.5 ft) drop – Withstands dust and water—tested to an IP 54 rating – Innovative protective lens cover protects the lens when not in use • Delivers the clear, crisp images needed to find problems fast – Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD) – Even the smallest details become visible with the large, widescreen full color LCD display • Intuitive, three-button menu is easy to use... simply navigate with the push of a thumb Specialty models Find problems faster with Fluke thermal imagers. Turn to the high performance Fluke FlexCam® line when you need a 5 inch high-contrast LCD and superior on-imager analysis capabilities. Images stored on a 1 GB compact flash card can be downloaded to a computer with included USB cable or card reader. Offers video out for live sharing of thermal images. Additional lenses are available. Fluke puts powerful technology within your reach. See page 44 for IR-Fusion Technology—only available from Fluke. See page 48 for recommended accessories. Specifications Features Temperature measurement range (not calibrated below -10 °C) Temperature measurement accuracy On-screen emissivity correction On-screen reflected background temperature compensation On-screen transmission correction Image capture frequency Detector type Thermal sensitivity (NETD) Field of view (standard lens) Spatial resolution (IFOV) Optional telephoto infrared lens Optional wide-angle infrared lens Standard palettes Ultra contrast palettes IR Fusion® Color alarms (user selectable) Voice annotation Storage medium Export file formats w/included SmartView® Software Batteries AC battery charging AC operation Enclosure rating Drop tested Warranty TI32 -20 °C to +600 °C (-4 °F to + 1112 °F) TI25 -20 °C to +350 °C (-4 °F to + 662 °F) ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) Ti10 -20 °C to +250 °C (-4 °F to + 482 °F) ± 5 °C or 5 % (at 25 °C nominal, whichever is greater) Yes Yes Yes 60 Hz or 9 Hz refresh rate depending on model 320 X 240 Focal Plane Array, 160 X 120 Focal Plane Array, uncooled uncooled microbolometer ≤ 0.05 °C at 30 °C target temp. ≤ 0.1 °C at 30 °C target temp. ≤ 0.2 °C at 30 °C target temp. (50 mK) (100 mK) (200 mK) Field of View: 23 ° x 17 °; Minimum Focus Distance: 15 cm (approx. 6 in) 1.25 mRad 2.5 mRad Yes Yes Ironbow, Blue-Red, High Contrast, Ironbow, blue-red, high contrast, Ironbow, blue-red, high contrast, Amber, Amber Inverted, Hot Metal, amber, hot metal, grey grey Grayscale, Grayscale Inverted Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Yes High-temperature alarm 60 seconds maximum recording time per image; reviewable playback on imager SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader Resources Hands-on training, Webinars, virtual demos and more. www.fluke.com/titraining This tool will help determine the return on investment of a Fluke Thermal Imager. www.fluke.com/roi BMP, DIP, GIF, JFIF, JPE, JPEG, JPG, PNG, TIF, and TIFF Two Lithium Ion rechargeable smart battery packs with 5-segInternal rechargeable battery pack (included) ment LED Display to show charge Battery life: 3-4 hours level. Battery life: 4+ hours; Battery charge: 2.5 hours to full charge Battery charge: 2.5 hours to full charge Two-bay AC battery charger AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), (110 V ac to 220 Vac, 50/60 Hz) charges battery while imager is operating or turned off, ac mains (included), or in-imager charging, adapters included ac mains adapters included AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz), ac mains adapters included IP54 2 m (6.5 ft) Two-year To download detailed specifications for these products go to www.fluke.com/tispecs Ordering information Included accessories In-box training DVD, SmartView® analysis and reporting software, 2 GB SD memory card, multi-function memory card reader, hard carry case, soft carry case, hand strap, two external smart rechargeable batteries, ac charger/power supply.* *Included accessories vary by model. AC adapter, video cable, 1 GB compact flash card, compact flash card reader and USB cable, PCMCIA compact flash card adapter, SmartView reporting and analysis software, two rechargeable battery packs, battery charger, neck strap, heavy duty carrying case and users manual on CD. 46 Thermal Imaging Models FLK-Ti25 9HZ Thermal Imager FLK-Ti10 9HZ Thermal Imager FLK-Ti32 9HZ Industrial-Commercial Thermal Imager FLK-Ti32 60HZ Industrial-Commercial Thermal Imager FLK-Ti40FT-20 IR FlexCam Thermal Imager FLK-Ti45FT-20 IR FlexCam Thermal Imager FLK-Ti50FT-20 IR FlexCam Thermal Imager FLK-Ti55FT-20 IR FlexCam Thermal Imager Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/thermal_imaging Ti Series Buildings Thermal Imagers Optimized for energy audits and moisture detection The ultimate tools for energy audits, building maintenance, restoation and remediation. • Enhanced problem detection and analysis capabilities with patent-pending IR-Fusion® Technology—only available from Fluke • Optimized for field use – Engineered and tested to withstand a 2 m (6.5 ft) drop – Withstands dust and water—tested to an IP 54 rating – Innovative protective lens cover protects the lens when not in use • Delivers the clear, crisp images needed to find problems fast – Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD) – Even the smallest details become visible with the large, widescreen full color LCD display • Intuitive, three-button menu is easy to use... simply navigate with the push of a thumb ee page 44 for IR-Fusion Technology—only available from Fluke. TiR32 shown with optional wide angle lens See page 48 for recommended accessories. Specialty models FlexCam® Thermal Imagers The experts’ choice for building diagnostics The Fluke TiR3FT and TiR4FT Thermal Imagers are for professionals demanding the best and most thorough solutions in building diagnostics applications. The Fluke TiR-Series provides the industry’s largest LCD to view on-camera images, augmented with the innovative IR-Fusion® Technology to better pinpoint building problems. IR-Fusion is the overlay of IR and visible images, allowing one to clearly identify critical points within the thermal image. Specifications Features Temperature measurement range (not calibrated below -10 °C) Temperature measurement accuracy On-screen emissivity correction On-screen reflected background temperature compensation On-screen transmission correction Image capture frequency Detector type Thermal sensitivity (NETD) Field of view (standard lens) Spatial resolution (IFOV) Optional telephoto infrared lens Optional wide-angle infrared lens Standard palettes Ultra contrast palettes IR Fusion® Color alarms (user selectable) Voice annotation Storage medium Export file formats w/included SmartView® Software Batteries AC battery charging AC operation Enclosure rating Drop tested Warranty TIR32 -20 °C to +150°C (-4 °F to + 302 °F) TIR1 TiR -20 °C to +100 °C (-4 °F to + 212 °F) ± 2 °C or 2 % (at 25°C nominal, whichever is greater) ± 5 °C or 5 % (at 25°C nominal, whichever is greater) Yes Yes Yes 60 Hz or 9 Hz refresh rate depending on model 320 X 240 Focal Plane Array, 160 X 120 Focal Plane Array, uncooled uncooled microbolometer ≤ 0.05 °C at 30 °C target temp. ≤ 0.07 °C at 30 °C target temp. ≤ 0.1 °C at 30 °C target temp. (50 mK) (70 mK) (100 mK) Field of view: 23 ° x 17 °; minimum focus distance: 15 cm (approx. 6 in) 1.25 mRad 2.5 mRad Yes Yes Ironbow, Blue-Red, High Contrast, Ironbow, blue-red, high contrast, Ironbow, blue-red, high contrast, Amber, Amber Inverted, Hot Metal, amber, hot metal, grey grey Grayscale, Grayscale Inverted Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Yes Dew point-temperature alarm 60 seconds maximum recording time per image; reviewable playback on imager SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader BMP, DIP, GIF, JFIF, JPE, JPEG, JPG, PNG, TIF, and TIFF Two Lithium Ion rechargeable smart battery packs with 5-segInternal rechargeable battery pack (included) ment LED Display to show charge Battery life: 3 to 4 hours level. Battery life: 4+ hours; Battery charge: 2.5 hours to full charge Battery charge: 2.5 hours to full charge Two-bay ac battery charger AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), (110 V ac to 220 V ac, 50/60 Hz) Charges battery while imager is operating or turned off, (included), or in-imager charging, ac mains adapters included ac mains adapters included AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz), ac mains adapters included IP54 2 m (6.5 ft) Two-year Fluke TiS Building Diagnostics Thermal Imaging Scanner The new Fluke TIS is the top-performing imager in its price class and meets the proposed RESNET infrared inspection standards. • 120 x 120 resolution • Largest display in price class, 30 % larger than comparable models • Award winning design, built rugged to withstand 2 m (6.5 ft) drop Resources Thermal imaging equipment solution center These tools can help you find out more about thermal imaging whether you currently own a thermal imager or are considering a purchase. www.fluke.com/tisolutions To download detailed specifications for these products go to www.fluke.com/tispecs Ordering information Included accessories In-box training DVD, SmartView® analysis and reporting software, 2 GB SD memory card, multi-function memory card reader, hard carry case, soft carry case, hand strap, two external rechargeable batteries, ac charger/power supply and users manual.* *Included accessories vary by model. AC adapter (TiR4FT only), video cable, 1 GB compact flash card, compact flash card reader and USB cable, PCMCIA compact flash adapter, SmartView reporting and analysis software on CD, two rechargeable battery packs, battery charger, neck strap, heavy duty carrying case and users manual on CD. Models FLK-TiR32 9HZ Building Diagnostics Thermal Imager FLK-TiR32 60HZ Building Diagnostics Thermal Imager FLK-TIR1 9HZ Thermal Imager FLK-TIR 9HZ Thermal Imager FLK-TiR3/FT-20 IR FlexCam BD Thermal Imager FLK-TiR4/FT-20 IR FlexCam BD Thermal Imager FLK-TiS 9HZ IR BD Thermal Imager For more information, go to www.fluke.com/thermal_imaging Check price and availability at www.fluke.com/wtb Thermal Imaging 47 Thermal imaging resources from Fluke Everything you need to use a Fluke thermal imager If you currently own a Fluke thermal imager or are considering a purchase, please visit the Fluke Thermal Imaging Resource site at www.fluke.com/titools. Learn more about the value of thermal imaging and why Fluke thermal imagers and SmartView® software are the best solutions on the market today. Watch a video, take a virtual demo, and view or download other useful information and tools. Product demos Recommended accessories BOOK-ITP FLK-LENS/TELE1 Introduction to Thermography Principles Book Telephoto Infrared Lens (Ti32 and TiR32 only) Find the thermal imager that best fits your application Go to www.fluke.com/select. Use our online product selection guide to find out the best Fluke thermal imager for your application. FLK-LENS/WIDE1 TI-CAR-CHARGER Wide-Angle Infrared Lens (Ti32 and TiR32 only) Thermal Imager Car Charger (all models except FlexCam) Building Inspection with a Fluke thermal imager—a video TI-VISOR TI-SBP3 Thermal Imager Sun Visor (all models except FlexCam) Smart Battery Pack (Ti32 and TiR32 only) SmartView software demo Sample applications Moisture detection: Accurately detect moisture behind interior walls, in ceilings, and under carpets. Mold remediation: Control mold by revealing undetected sources of moisture. 48 Thermal Imaging TI-SBC2 103232 Charging Base (Ti32 and TiR32 only) Anti-glare Hood (FlexCam models only) 104543 TI-SBC Car Charger (FlexCam models only) Battery Charger (FlexCam models only) Roofing: Detect water-saturated insulation in flat-roof systems to locate damaged portions of roofing structure. Energy audits: Perform residential and commercial energy audits by scanning for heating or cooling (energy) loss, moisture invasion, and HVAC/R problems. TI-SBP TI-TRIPOD Rechargeable Battery Pack (FlexCam models only) Ti Tripod Mounting Base (all models except FlexCam) Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/thermal_imaging Fluke 560 Series Infrared Thermometers Fluke 566 and 568 IR and Contact Thermometers Just when you thought advanced IR temperature measurement should be easier! With a straightforward user interface and soft-key menus, the Fluke 566 and 568 make even complex measurements easy. With just a few pushes of a button you can easily adjust emissivity, start data logging, or turn on and off alarms. With a rugged, easy-to-use design, the Fluke 566 and 568 can stand up to tough industrial, electrical, and mechanical environments. • Measure up to 800 °C (1470 °F) • Easily access advanced features with the softkey buttons and graphical display • Measure smaller objects from further away • Compatibility with most type-K thermocouples • Confidently measure more surfaces, with adjustable emissivity and built-in materials table • Log and download measurements for reporting (568) • Two levels of backlight • Audible and visual alarms alert you to measurements outside of set limits • Min, Max, Avg, and Dif functions • Includes KTC bead probe • 1 % measurement accuracy • Versatile interface with six languages Specifications Models Infrared temperature range Fluke 561 Fluke 566 Fluke 568 Fluke 68IS Fluke 62 -40 °C to 535 °C (-40 °F to 1022 °F) -40 °C to 650 °C (-40 °F to 1200 °F) -40 °C to 800 °C (-40 °F to 1470 °F) -32 °C to 760 °C (-25 °F to 1400 °F) -30 °C to 500 °C (-20 °F to 932 °F) greater of ± 1 % or ± 1 °C (2 °F) greater of ± 1.5 % or ± 1 °C (2 °F) 50:1 10:1 Up to 7.5 m (25 ft) Up to 2 m (6 ft) Accuracy greater of ± 1 % or ± 1 °C (2 °F) Distance to Spot (D:S) 12:1 30:1 50:1 Sighting Typical distance to target Up to 2.5 m (7 ft) Up to 4.5 m (15 ft) Up to 7.5 m (25 ft) Thermocouple K -40 °C to 550 °C (-40 °F to 1022 °F) RTD -270 °C to 1372 °C (-454 °F to 2501 °F) Number of on-board memory locations 20 The Fluke 561 combines the temperature measurement functions that professionals need for most HVAC and industrial jobs, all in one tool. • Pipe probe for superheat and sub-cooling and other contact and ambient measurements • Min, Max and Dif functions help you quickly identify problems • Scan large areas or small objects quickly and efficiently Fluke 61 Infrared Thermometers • Easy to use one button operation • Easy targeting with bright laser • Shock-absorbing molding increases ruggedness • Two-year conditional warranty • Temperature measurement range up to 275 °C (525 °F) • 8:1 optics • Accurate to within ± 2 % of reading or 2 °C, whichever is greater Recommended accessories -40 °C to 260 °C (-40 °F to 500 °F) 99 PC download and software 12 Yes, with FlukeView® Forms Soft-key feature menu navigaton Yes Min/Max/Avg/Dif Min/Max/Dif Min/Max/Avg/Dif English, French, Chinese, Spanish, Portuguese, German user interface Min/Max/Avg/Dif Max Yes Material type adjustment (emissivity) Hi/Med/Lo Material table or 0.1 to 1.00 by 0.01 Two levels of backlight 0.1 to 1.00 by 0.01 80PK-11 80PK-27 Pipe Clamp Probe See page 58 Industrial Surface Temperature Probe See page 58 Preset to 0.95 Yes High and low alarms High and low alarms Hazardous location approval High and low alarms FM approved intrinsically safe Hands-free logging Yes Battery Included case Fluke 561 Infrared and Contact Thermometer Laser point Probe type Contact temperature range Specialty models 2 AA Hard case (except 561/R and 561/P) Warranty 9V Hard case Soft case Two-year 80PK-10 80PK-18 Pipe Clamp Temperature Probe See page 58 Pipe Clamp Temperature Probe See page 54 Ordering information Included accessories Models USB cable, FlukeView® Forms software, thermocouple K-type bead probe, carrying case, two AA batteries, users manual, quickstart guide. FLUKE-568 Infrared Thermometer Thermocouple K-type bead probe, carrying case, two AA batteries, users manual and quickstart guide. FLUKE-566 Infrared Thermometer Thermocouple K-type pipe probe, carrying case, two AA batteries, users manual. FLUKE-561 Infrared Thermometer 9 V battery, instruction sheet. FLUKE-61 Infrared Thermometer For more information, go to www.fluke.com/thermometers Check price and availability at www.fluke.com/wtb Thermometers 49 Fluke 62 Mini Infrared Thermometer Non-contact temperature measurement The Fluke 62 Mini non-contact thermometer is the perfect introduction to infrared (IR) thermometers for the professional. With the best accuracy in its class, the Fluke 62 mini offers quick and reliable surface temperature readings. This compact and portable tool enables professionals to diagnose heating and ventilation problems and monitor the temperature of electrical motors and electrical panels without contact. • Accurate to within ± 1.5 % of reading or ± 1.5 °C • Temperature measurement range up to 500 °C (932 °F) • 10:1 optics • Backlit display for poorly lit areas • Laser sighting • Dual display shows current and max measurements simultaneously Fluke 50 Series II Thermometers Lab accuracy in a field thermometer Specialty models Fluke 570 Series Infrared Thermometers The Fluke 572 and 574 are ideal diagnostic tools for maintenance professionals requiring accurate temperature readings at all distances. Predictive maintenance professionals requiring analysis and documentation use the 574 model, with 100-point data logging with the included software for graphing and analysis for follow-up reporting and documentation. • Backlit display for poorly lit areas • Displays last ten temperature readings • Enhanced optics (distance to spot ratio up to 60:1) Intrinsically safe model on page 39. All models offer: • Laboratory accuracy: ± (0.05 % + 0.3 °C) • Large backlit dual display • Min/Max/Avg • Electronic offset function maximizes overall accuracy • Supports a wide range of thermocouple types • Temperatures displayed in °C, °F, or Kelvin (K) Recommended kits 62/T+PRO/1AC-II Powerful data logging capabilities The Fluke 53 II B and 54 II B can log up to 500 points of data to internal memory. • User-adjustable recording intervals • Real-time clock captures the exact event time • Recall function lets logged data be easily reviewed • Download data to optional FlukeView® PC software • 62 Non-contact Thermometer • T+RO Electrical Tes • 1AC-II Voltage Dete • Carrying case T5-600/62/1AC-II Kit • Fluke 62 Mini IR Thermometer • Fluke T5-600 Vol Electrical Tester • 1AC-II Voltage Detector • Carrying case Features Features Thermocouple types 54 II B 53 II B 52 51 K,J,T,E,N,R,S K,J,T,E,N,R,S K,J,T,E K,J,T,E Dual Single Dual Single Time of day Time of day Number of inputs Time stamp • Fluke 62 Mini IR Thermometer • Fluke 322 Clamp Me • 1AC-II Voltage Dete • Test leads • Carrying case Ordering information Included accessories Models Storage pouch and instruction sheet. FLUKE-62 Mini Infrared Thermometer FLUKE-62/T+PRO/1AC IR Thermometer, Electrical Tester and Voltage Detector Kit FLUKE-T5-600/62/1AC IR Thermometer, Electrical Tester and Voltage Detector Kit FLUKE-62/322/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit FLUKE-411D/62 IR Thermometer and Distance Laser Meter Kit FLUKE-54-2-B Datalogging Thermometer, Dual Input FLUKE-53-2-B Datalogging Thermometer, Single Input FLUKE-52-2 Digital Thermometer, Dual Input FLUKE-51-2 Digital Thermometer, Single Input Bead thermocouple(s), batteries, overview manual and instructional guide on CD. Thermocouple K probe (574), power supply (574), RS-232 data cable (574), data graphing, storage and analysis software on CD (574), hard case, two AA batteries, operator’s guide on CD. 62/322/1AC-II Kit FLUKE-574-CF Precision Infrared Thermometer w/Logging SW Close Focus FLUKE-574 Precision Infrared Thermometer w/Logging SW FLUKE-572-CF Precision Infrared Thermometer with Close Focus Option FLUKE-572 Precision Infrared Thermometer 62-411D Kit • Fluke 62 Mini IR Thermometer • Fluke 411D Lase Distance Meter • Soft pouch for each model Check price and availability at www.fluke.com/wtb 50 Thermometers For more information, go to www.fluke.com/thermometers Hawk IR C-Range IR-Windows Got switchgear? Use arc-resistant IR Windows with Quadraband™ optic technology Applications Infrared windows mount into panel doors and covers for switchgear, transformers, buss bars and other live electrical equipment, allowing thermal, ultraviolet, visual and fusion technologies to be used without exposing personnel to live equipment. • Reduce the risk associated with electrical thermography • Reduce labor required to inspect your switchgear from three heads to one • Stay safety compliant with NFPA 70E and other safety protocols and leave the panels closed • Extend the life of your equipment with more frequent IR scans • Easy to install • Durable enough to withstand extreme outdoor conditions yet practical for indoor applications as well Fluke CLKT Fluke CLKTO Fluke 1524/1523 Reference Thermometers The 1523/24 Reference Thermometers from the Hart Scientific Division measure, graph, and record PRTs, thermocouples, and thermistors. You can measure up to 0.3 seconds per sample and plot and scale trends in real time. Both thermometers have memory for up to 25 readings with statistics. The 1524 has 2 inputs with data logging memory for 15,000 measurements with date and time stamps. Temperature probes are required for measurements and are sold separately as accessories. The universal thermocouple adapter is configurable for different thermocouple types and has memory for calibration coefficients. Free IOToolkit software is included for updating password protected calibration information stored in 1523/1524 probe connectors. Accuracies of selected readout/probe combinations including readout accuracy probe calibration and probe drift (± °C). Features Temperature 5616-12 Recommended accessories Fluke 1524/1523 5616-12-P 5610-9-P Precision PRT 305 mm x 6.35 mm (12 in x .25 in) Precision Thermistor 229 mm x 3.2 mm (9 in x 1/8 in) 5610-9 -200 °C (-328 °F) 0.014 0 °C (32 °F) 0.021 0.009 100 °C (212 °F) 0.027 0.030 300 °C (572 °F) 0.040 420 °C (788 °F) 0.050 Equivalent temperature readout accuracy for measuring type K thermocouples is ± 0.24 °C (± 0.43 °F) from 0 °C to 1370 °C (32 °F to 2498 °F) and ± 0.61°C (± 1.10 °F) from –200 °C to 0 °C (–328 °F to 32 °F). Additional errors for thermocouple accuracy or calibration must be added separately. 2373-LTC FLK80K1 Smart connector with universal TC adapter 80PK-1 Type K Probe and adapter (2373-LTC) Ordering information Included accessories Models IR Windows are supplied complete, assembled and ready for installation. In addition to the IR Window each carton contains an installation CD, self-adhesive drilling template, security access key, warranty statement. FLK-050-CLKT 50 mm (2 in) C-Range IR Window, Kwik Twist FLK-075-CLKT 75 mm (3 in) C-Range IR Window, Kwik Twist FLK-100-CLKT 100 mm (4 in) C-Range IR Window, Kwik Twist FLK-075-CLKTO 75 mm (3 in) C-Range IR Window, Kwik Twist 12 V dc universal power supply, RS-232 cable, NIST traceable calibration certificate, technical manual and 9940 I/O ToolKit software on CD, three AA batteries, users guide. FLUKE-1524 Thermometer Readout (2 inputs) FLUKE-1523 Thermometer Readout (1 input) TPAK, 2373-LTC, carrying case. FLUKE-1524-P1 1524 Bundled with 5616 PRT FLUKE-1523-P1 1523 Bundled with 5616 PRT For more information, go to www.fluke.com TPAK Magnetic Meter Hanger See page 62 Check price and availability at www.fluke.com/wtb Thermometers/IR-Windows 51 Fluke 810 Vibration Tester Take a vibration expert along Get answers now! The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer NOW. It is a unique new kind of troubleshooting tool, engineered to detect and evaluate the most common mechanical problems. The Fluke 810 Vibration Tester uses a simple step-by-step process to report on machine faults the first time measurements are taken, without prior machine history. Software Viewer PC Software • Store and track your data • Generate diagnostic reports and track the severity of your machine’s condition • Import and store JPEG and Fluke IS2 thermal images Use the Fluke 810 to: • Easily determine the root cause, location and severity of common mechanical faults • Efficiently prioritize and plan equipment repair or replacement • Effectively deploy maintenance resources at the point of greatest impact Simple 3 step process The Fluke 810 helps you locate and diagnose common mechanical problems and prioritize repair actions in three simple steps: 1. Setup: Vibration testing 2. Measure: The Fluke 3. Diagnose: Fix it right has never been easier 810 fits easily into the first time: With the The Fluke 810 asks for your maintenance press of a button, the basic machine informaroutine. Use it to quickly Fluke 810 identifies the tion you already know, troubleshoot problems root cause, its location, like RPM and horseor monitor machine and the problem’s power. Its onboard Info condition. severity. feature gives you field tips for setting up and taking measurements like a pro. Application tips Breakthrough diagnostic technology The Fluke 810’s diagnostic technology combines powerful algorithms with a database of real-world measurement experience, making the Fluke 810 the most advanced troubleshooting tool for mechanical maintenance teams. Analyze most common equipment: • Motors • Fans and blowers • Belt and chain drives • Gearboxes • Pumps • Compressors • Spindles Specifications Diagnostic specifications Analysis for Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles Machine rotational speed range 200 rpm to 12000 rpm Diagnosis details Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra IP rating IP 54 4 channel, 24 bit Dynamic range 128 dB FFT resolution 800 lines Battery Lithium-ion, rechargeable, 8 hours operating life Onboard storage capacity 2 GB internal micro SD card Warranty Three-years (tester), One-year (sensor and tachometer) Sensor specifications Sensor type Tri-axial accelerometer , 100 mV/g (± 5 %, 25 °C) Tachometer specifications Tachometer type Laser Diode Class 2 Ordering information 52 Included accessories Models Tri-axial accelerometer, magnet mount, mounting pad kit with adhesive, quickdisconnect accelerometer cable, laser tachometer with storage pouch, battery pack with cable and adapters, shoulder strap, adjustable hand strap, Viewer PC software, mini USB to USB cable, carrying case, training DVD, getting started guide, quick reference guide, users manual on DVD. FLUKE-810 Vibration Resources Interactive, selfpaced training on DVD Learn more about the basics of vibration and how to fully utilize the features and functionality of the Fluke 810. Fluke has partnered with Mobius Institute, an industry leader in vibration training, to develop an interactive training DVD included with each Fluke 810. Tester specifications A/D converter Detect the most common causes of mechanical failure: • Bearing problems • Misalignment • Unbalance • Looseness FLUKE-810 Vibration Tester Check price and availability at www.fluke.com/wtb For more information, go to www.fluke.com/vibration Accessories as tough as your meter TPAK Meter Hanger— hang your meter from magnetic surfaces and free both hands (see p. 62) TL175 TwistGuard Test Leads—get two category ratings with one set of test leads and a wire that changes color when the leads need to be replaced AC285 SureGrip Alligator Clips—SureGrip rubber provides a reliable, ergonomic grip in slippery hands (see p. 57) When your job depends on your meter... your meter depends on Fluke Genuine Accessories (see p. 57) 53 Fluke cases and holsters A premium meter deserves a premium case C550 CXT80 • • • CXT80 • CXT170 • • • • • • • • • • • C520A The C550 and C1600 are large enough to hold accessories and multiple test tools C550/C1600 • • • • • C25 • • • • • • • • • C33 • C35 • C43 C90 • • • C115/C116 • • • • • • • • • • • • • C800 Accessories • • • • C100 • • • • • • • • • • • • • • • • • • • • 789 • • • • C789 54 • • C781 C510 • • • • • • • • • • C125 C101 • 28x • • • • • • • • • • • • • • • • • • • • • • • 787 • • • 787 • • • 787 H5 C345 Soft Case • Made of durable polyester 600D • Dimensions (HxWxD): 360 x 200 x 240 mm (14 x 8 x 9.5 in) Hard cases CXT Series Extreme Cases • Models CXT80, CXT170, and CXT280 for various meter compatibility • Unbreakable, watertight, airtight, chemical resistant and corrosion proof C800 Meter and Accessory Case • Dimensions (HxWxD): 230 x 385 x 115 mm (9 x 15 x 4.5 in) C20 Hard Case • Made of polyprophylene • Dimensions (HxWxD): 256 x 154 x 106 mm (10 x 6.1 x 4.2 in) C101 Hard Case • Exterior dimensions (HxWxD): 305 x 360 x 105 mm (12 x 14.2 x 4.1 in) • Interior dimensions (HxWxD): 230 x 290 x 65 mm (9 x 11.5 x 2.5 in) C100 Universal Carrying Case • Dimensions (HxWxD): 397 x 346 x 122 mm (15.7 x 13.6 x 4.8 in) C1600 Gear Box • Includes five hook and loop straps to wrap cords and test leads • Dimensions (HxWxD): 260 x 390 x 200 mm (10 x 15 x 7.8 in) Leather cases C520A Leather Tester Case • Dimensions (HxWxD): 256 x 154 x 106 mm (10 x 6 x 4 in) C510 Leather Meter Case • Dimensions (HxWxD): 287 x 179 x 106 mm (11 x 7 x 4 in) Holsters • • 18x • CXT280 C12A 1503/1507/1577/1587 725/726 • T3/T5 718 • 787/789 714/715/716/717 • 741/743/744 712/713 • 705/707 330 Series • The perfect case for carrying a wide range of Fluke handheld test tools and accessories C345 C50 • 321/322 • 63/66/68 • 50 Series II 287/289/187/189 • 120 Series 233 • 43B 80 Series III/83V 87V/89 IV • 39/41B 175/177/179 • C280 27 II/28 II/27 20/70 Series 114/115/116/117 110/111/112 10/11/12/12B C12A Meter Case • Made of vinyl • Dimensions (HxWxD): 172 x 128 x 38 mm (6.8 x 5 x 1.5 in) C75 Accessory Case • Made of vinyl • Dimensions (HxWxD): 179 x 103 x 26 mm (7 x 4 x 1 in) C50 Meter Case • Made of vinyl • Dimensions (HxWxD): 192 x 90 x 38 mm (7.56 x 3.5 x 1.5 in) C25 Large Soft Case for DMMs • Made of vinyl • Dimensions (HxWxD): 218 x 128 x 64 mm (8.6 x 5 x 2.52 in) C90 Soft Case for DMMs • Made of vinyl • Dimensions (HxWxD): 205 x 90 x 72 mm (8 x 3.5 x 2.8 in) C35 Soft Carrying Case • Made of durable polyester 600D • Dimensions (HxWxD): 220 x 140 x 65 mm (8.7 x 5.5 x 2.6 in) C23 Soft Carrying Case • Made of durable vinyl • Dimensions (HxWxD): 225 x 95 x 58 mm (8.9 x 3.75 x 2.3 in) C280 Soft Case • Made of durable polyester 600D • Dimensions (HxWxD): 230 x 185 x 65 mm (9 x 7.3 x 2.6 in) Selection Guide C510 C115 Soft Carrying Case • Made of durable polyester 600D • Dimensions (HxWxD): 240 x 205 x 75 mm (9.5 x 8 x 3 in) C116 Soft Carrying Case • Made of durable polyester 600D • Dimensions (HxWxD): 240 x 230 x 65 mm (9.5 x 9 x 2.6 in) C570 Soft Case • Made of vinyl • Dimensions (HxWxD): 240 x 89 to 170 x 56 mm (9.5 x 3.5 to 6.7 x 2.2 in) C781 Meter Case • Made of durable polyester 600D • Dimensions (HxWxD): 269 x 141 x 90 mm (10.6 x 5.6 x 3.5 in) C33 Soft Carrying Case • Made of vinyl • Dimensions (HxWxD): 280 x 115 x 55 mm (11 x 4.5 x 2.2 in) C789 Meter and Accessory Case • Made of durable polyester 600D • Dimensions (HxWxD): 308 x 256 x 77 mm (12 x 10 x 3 in) C43 Soft Carrying Case • Made of durable polyester 600D • Dimensions (HxWxD): 318 x 230 x 90 mm (12.5 x 9.1 x 3.5 in) C550 Tool Bag • Made of ballistic cloth with heavy-duty hardware • Dimensions (HxWxD): 333 x 513 x 231 mm (13 x 20.2 x 9.1 in) Soft cases 50S/50D C35 • • C10 Meter Holster • Compatible with Fluke 10 Series Multimeters • Dimensions (HxWxD): 154 x 77 x 45 mm (6 x 3 x 1.8 in) H80M Protective Holster • Includes a hanging magnet, general purpose hanger, and hook and loop straps • Dimensions (HxWxD): 190 x 95 x 43 mm (7.5 x 3.7 x 1.7 in) H5 Electrical Tester Holster • Dimensions (HxWxD): 192 x 90 x 38 mm (7.5 x 3.5 x 1.5 in) H3 Clamp Meter Holster • Dimensions (HxWxD): 231 x 90 x 64 mm (9 x 3.5 x 2.5 in) H6 IR Thermometer Holster • Dimensions (HxWxD): 302 x 178 x 57 mm (11.9 x 7 x 2 in) For more information, go to www.fluke.com/accessories Fluke accessory sets and kits Save money on our most popular accessories TL220 Industrial Test Lead Set TL223 Electrical Test Lead Set • • • • • • • • Starter kit for industrial applications TP220 has round, stainless steel tip Includes 1 pair: AC220, TP220, TL222 CAT III 1000 V, CAT IV 600 V, 10 A TLK-220 SureGrip™ Accessory Kit with Meter Carry Case Starter kit for electrical applications TP1 has flat blades for wall sockets Includes 1 pair: AC220, TP1, TL224 CAT III 1000 V, CAT IV 600 V, 10 A • • • • • Plunger style alligator clips Large jaw alligator clips Sharp test probes Right to straight test leads Zippered vinyl carry case with moveable divider • Holds large DMMs 287/289/187/189 39/41B/43B 90 Series 120 Series 190 Series 321/322 330 Series 705/707 715 716/717 718 725/726 741/743 744 787/789 1587 1577 • 87V/233 TLK287 80 Series Selection Guide 179 • • • • • • • 175/177 Designed for electrical and electronics test in today’s industrial environment • SureGrip™ alligator clips, grabbers, hook clips and industrial test probes for dependable contact with a variety of test points • Magnetic hanger for suspension of your DMM • Temperature adapter with K-Type thermocouple for direct temperature measurement with your DMM’s 27 II/28 II/27 The perfect test lead kit for today’s electronics test and design • Precision electronic probes with multiple spring-loaded sharp tips to maximize contact with SMD test points • Micro-grabbers and leads to enable fine SMD test • Modular mini-alligator clips, grabbers, leads, probes, and couplers for virtually every electronics need 20/70 Series TLK-225 SureGrip™ Master Accessory Kit 114/115/116/117 TLK289 Industrial Master Test Lead Set and Case 10/110 Series TLK287 Electronics Master Test Lead Set • • • • • • • • • • • • • • • • • • • • • • • • • 116 TLK289 • • • TL220 • • • • • • • • • • • • • • • • • • • • • • • • • TL223 • • • • • • • • • • • • • • • • • • • • • • • • • TL225 • • • • • • • • • • • • • • • • • • • • • • • • • TL238 • • • • • • • • • • • • • • • • • • • • • • • • • TL80A • • • • • • • • • • • • • • • • • • • • • • • • • TL81A • • • • • • • • • • • • • • • • • • • • • • • • • TL71 • • • • • • • • • • • • • • • • • • • • • • • • • TL76 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 80K-8, 80K-15, 80K-40 dc dc only only Plunger style alligator clips Plunger style hook clips Plunger style pincer clips Large jaw alligator clips Sharp test probes Right to straight test leads 6-pocket storage pouch, keeps the entire set together For more information, go to www.fluke.com/accessories T5 Tester Starter Kit Getting started kit for electricians who already own a Fluke T5 Tester. • Test probes • Large jaw alligator clips • Zippered soft case • Accessories 55 Fluke test leads, probes and clips The best leads for all your measurement needs For electronic applications For automotive applications TP81 and TP82 • Stainless steel probe pierces insulation on 14, 16 and 18 gauge wire • Design provides complete insulation while working on fuel injectors or sensors • TP81 for use with modular test leads (Fluke TL224) • TP82 slips over probe tips (Fluke TL71) • Rated to 60 V dc TL80A Basic Electronic Test Lead Set • 6 piece set with zippered case • Probes, alligator clips and tip extenders for electronic applications • CAT II 300 V TL910 Electronic Test Probes with Replacement Tips • Small profile provides accessibility • Comes with 5 sets of replaceable tips • Replacement tips: TP912 • CAT III 1000 V, 3 A TP80 Electronic Test Probes • Tapered tip ideal for probing electronic components or boards • Removable guard for IC probing • CAT III 1000 V, 10 A TP920 Test Probe Adapter Kit • IC test tip adapters, extended tips, medium alligator clips fit over TL71 and TL75 test lead sets • IC test tip Adapter, 3 A • Extended probe tip, 3 A • Med. alligator clip, 5 A • CAT II 300 V TP88 Rigid Backprobe Pin Set • 2 inch long pins pass between the weather pack seal a • Use with Fluke TL71 lead sets • Rated to 60 V dc TP40 Automotive Back Probe Pin Set • Set of five 1.5 inch pins • Rated to 60 V dc • Provide an easy connection past weather pack seals to connector conductors • Use with Fluke TL71 or TL75 test lead sets TL82 Automotive Pin & Socket Adapter Set • Collection of male and female adapters allows you to make firm connection to pin and socket connect • Adapters with flexible tips come in the following sizes: 22, 20, 16 and 12 • Rated to 60 V dc TLK281 Automotive Test Lead Kit • Insulation piercing probes • Suregrip silicone test leads • Suregrip test probes • Suregrip plunger style alligator clips • Suregrip alligator clips • Carrying case TLK282 Deluxe Automotive Test Lead Kit • Insulation piercing probes • Set of five automotive back probe pins • Suregrip silicone test leads • Suregrip test probes • Suregrip plunger style alligator clips • Suregrip alligator clips • Suregrip hook clips • Carrying case TL40 Retractable Probe Assembly • Retractable, insulated sharp probe tip • CAT III 300 V, 3 A TL26A Telecom Test Lead Set • 5-way multipoint test clips for telecommunications applications • Flexible silicone insulated leads are heat and cold resistant • CAT I 30 V, 8 A 56 Accessories High-voltage probes 80K-6, 80K-15, 80K-40 High Voltage Probes • Allows a digital multimeter to measure up to 6,000 volts peak, 15,000 volts peak and 40,000 volts peak respectively • 1000:1 division ratio output when connected to 10 MΩ multimeter • Ground clip included • Intended for low energy applications that are referenced to ground • 80K-15 (not available in Europe) For more information, go to www.fluke.com/accessories Fluke SureGrip™ accessories As tough as your meter SureGrip accessories provide a reliable grip in slippery hands. Rubber-overmolded surfaces and finger-hugging curves give the user a comfortable, steady hold on the accessory so they can focus on making an accurate measurement. Modular test leads and test probes (use test probes with test leads) FTPL SureGrip™ Fused Test Probes with Leads • FTP Fused Test Probes with built-in fuses for added protection • TL224 Silicone Insulated Test Leads • CAT III 1000 V, CAT IV 600 V, 10 A TL221 SureGrip™ Silicone Test Lead Extension Kit • Superior strain relief • Includes two adapters to extend leads 1.5 m • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A TL222 SureGrip™ Silicone Insulated Test Leads • Superior strain relief • Recommended for use with AC220, AC280, AC283 test clips • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A TL224 SureGrip™ Silicone Insulated Test Leads • Superior strain relief • 1.5 m silicone-insulated wire resists heat and cold • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A FTP SureGrip™ Fused Test Probes • Built-in fuses for added protection • 2 mm threaded probe tips include removable 4 mm lantern-style spring contacts • Removable GS38 insulated IC caps for probing closely spaced leads • CAT III 1000 V, CAT IV 600 V, 10 A TP1, TP2, TP4 and TP38 Slim Reach™ Test Probes • Slender probe bodies for probing closely spaced or recessed points • TP1 has a flat blade • TP2 has 2 mm diameter tip • TP4 has 4 mm diameter tip • TP38 has stainless steel insulated probe to help lessen the risk of arc flash explosion • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A TP220 SureGrip™ Industrial Test Probes • Sharp, 1/2 inch stainless steel tip provides reliable contact • Flexible finger barrier improves grip • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A Modular clips (use with test leads, includes one red, one black) AC220 SureGrip™ Alligator ator Clips • Insulated, nickel plated d jaws grip objects up to 3/8 in. • Blunt tip grabs round screw heads • CAT III 1000 V, CAT IV 600 V, 10 A AC72 Alligator Clips • Slide-on style for test pro • Jaws open to 8 mm • For use with TL71 and TL75 test lead and probe sets • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A AC283 SureGrip™ Pincer Clips • 4.5 in. flexible, insulat • Nickel plated pincers o to .20 in. • CAT III 1000 V, CAT IV 600 V, 1 A AC285 SureGrip™ Alligator Clips • Multi-purpose tooth pattern grips anything from fine gauge wire to a 3/4 in. nut • Nickel-plated steel jaws • CAT III 1000 V, CAT IV 600 V, 10 A AC280 SureGrip™ Hook • Profile narrows to .22 i • Hook opening .20 in. a .08 in. at base • CAT III 1000 V, CAT IV 600 V, 3 A For more information, go to www.fluke.com/accessories The new standard for safer electrical measurements TL175 TwistGuard™ Test Leads • Probes meet new IEC 61010-031 requiremen • Patented ex sheath mee CAT III 100 CAT IV 600 requirements while providing the flexibility you need for CAT II measurements • New WearGuard™ test lead wear indicator that changes color when leads are damaged and in need of replacement • Probes always show correct category rating for tip being used • Advanced strain relief exceeds 5,000 bend life • TP175 probes fit standard test leads y twist Simpl handle probe ud Shro s drop TL238 SureGrip™ Test Lead Set for high energy environments • Insulated tip probes help lessen risk of arc flash explosion • Probe extenders keep hands away from live current • Includes one pair each, insulated test tip probes, probe extenders and TL224 Test Leads • Probes and leads CAT III 1000 V, CAT IV 600 V, 10 A, extenders CAT III 1000 V 10 A TL71 Premium DMM Test Lead Set • Flexible silicone insulated leads are heat and cold resistant • Distinctive comfort grip probes • Recommended for µV measurements • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A TL75 Hard Point Test Lead Set • Extremely hard alloy tips resist wear • Distinctive comfort grip probes • 1.5 m PVC leads • CAT III 1000 V, 10 A, CAT IV 600 V, 10 A Accessories 57 Fluke Temperature accessories Turn your digital multimeter into a thermometer Other temperature accessories 80TK Thermocouple Module • Converts K-Type thermocouple signals into mV output • Connects to DMM via standard banana plugs • Switch selectable °C or °F • Range: -50 °C to 1000 °C (-58 °F to 1832 °F) • Includes 80PK-1 probe 80T-150UA Universal Solid State Temperature Probe • For measurement of air, surface and non-corrosive materials • Measurement range: -50 °C to 150 °C (-58 °F to 302 °F) • Output: 1 mV/°C or 1 mV/°F (switch selectable) • Connects to DMM via standard banana plugs 80AK-A DMM Adapter • Adapts K-type thermocouple mini-connector to dual banana plug inputs • Compatible with all Fluke DMMs with temperature measurement functions • Measurement range and accuracy is not affected by the 80AK-A adapter 80BK-A Integrated DMM Temperature Probe • Compatible with all Fluk DMMs with temperature measurement functions • K-Type thermocouple with standard banana jack • Convenient one-piece construction • Measurement range: -40 °C to 260 °C (-40 °F to 500 °F) Thermocouple Plug Kits 700TC1 A kit of 10 mini-plug connectors. One each of the following: Type J (black) Type K (yellow) Type T (blue) Type E (purple) Type R/S (green) Type B or Cu (white) Type L (J-DIN) (blue) Type U (T-DIN) (brown) Type C (red) Type N (orange) 700TC2 A kit of 7 mini-plug connectors. Type J (black), two Type K (yellow), two Type E (purple), one Type T (blue), one Type R/S (green), one 80PR-60 RTD Temperature Probe • Resistance temperature detector probe designed to add contact measurements to your Fluke 66 and 68 Non-Contact Infrared Thermometers • Measurement range: -40 °C to 260 °C (-40 °F to 500 °F) • 3.5 mm phono type jack is only appropriate for Fluke 66 and 68 Thermometers 80CK-M and 80CJ-M Type K and J Male Mini-Connectors • Isothermal screw terminal for K or J wire • Suitable for up to 20 gauge thermocouple wire • Color coded to industry standards (K-yellow, J-black) • Two per package 80PJ-EXT, 80PKEXT, 80PT-EXT Thermocouple Wire Extension Kits For extending and repairing J, K or T-type thermocouple wires. • Kit includes 3 m (approx. 9 ft.) of thermocouple wire and 1 pair of male/female mini-connectors • Maximum continuous exposure temperature: 260 °C (500 °F) • 80PK-EXT is compatible with K-type thermometers; 80PJ-EXT is designed for J-Type thermometers, and 80PT-EXT is designed for T-type thermometers Process tools accessories BP7217 • NiCd rechargeable battery; nominal 7.2 volt, 1700 mA hr • Use in 867B meters or 700 and 740 Series Calibrators BP7235 • NiMH rechargeable battery; nominal 7.2 volt, 3500 mA hr • Use in 700 and 740 Series Calibrators 700LTP-1 Low Pressure Test Pump Hand operated pressure pump designed to generate either vacuum to -13 psi/ -.90 bar or pressures to 100 psi/6.9 bar. Ideal for low pressure applications requiring accurate low pressure testing. 700ILF In-line Filter The Fluke 700ILF can be used to isolate the calibrator from incidental contact with fluids. Particularly useful with the 718 calibrator to help keep moisture or oils from contaminating the on-board pump. 700PTP-1 Pneumatic Test Pump The Fluke 700PTP is a handheld pressure pump designed to generate either vacuum to -11.6 psi/-0.8 bar or pressure to 600 psi/40 bar. For more information, go to www.fluke.com/accessories 700HTP-1 Hydraulic Test Pump The Fluke 700HTP is designed to generate pressures up to 10,000 psi/700 bar. Use the Fluke-700PRV adjustable relief valves to limit pressures from 1360 psi to 5450 psi. 700HTH Hydraulic Test Hose The 700HTH is a 10,000 psi, 700 bar test hose that connects to a calibration unit under test from a Fluke 700HTP hydraulic test pump. 700PMP Pressure Pump The 700PMP is a handoperated pressure pump to provide pressures up to 150 psi/1000 kPa. Output fitting is 1/8 FNPT. Fluke 700-IV Current Shunt Conversion factor: 10 mV = 1 mA Accuracy (% of input, 1 year): 0.025 % Input current: 0 to 55 mA Input resistance: 250 Ω nominal Output resistance: 10 Ω nominal Accuracy specification applies from +18 °C and 28 °C to 50 °C Maximum input voltage: 30 V dc Accessories 59 Fluke current clamps For use with multimeters, ScopeMeters and power quality analyzers AC current clamp specifications AC current range Accuracy Bandwidth (-3 dB) AC only models i200 i200s i400 i400s i800 i1000s i3000s i2000 flex i3000s flex 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 400 A 1 A to 800 A 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 2 % + 0.06 A 45 Hz to 400 Hz .5 A to 40 A, 2 % + .015 A, 5 A to 400 A, 2 % + .04 A, 45 to 400 Hz 0.1 A to 10 A ± 3 % + .01 A, 10 A to 200 A ± 2 %, 200 A to 800 A ± 1 % 0.2 A to 1000 A 0.2 to 10 A: 3 % + 0.1 A 10 A to 100 A: 2 % + 0.5 A 100 A to 1000 A: 1%+1A 48 to 65 Hz 5 Hz to 100 kHz 54 mm (2.13 in) 1 to 30 A: 2 % + 0.1 A 1 to 300 A: 2 % + 0.5 A 1 to 3000 A: 2 %+2A 48 to 65 Hz ± 1 % of range 45 to 65 Hz Ranges: 20 A, 200 A, 2000 A ± 1 % of range, 45 Hz to 65 Hz Ranges: 30 A, 300 A, 3000 A < 3 % + 0.5 A < 1 % + 0.5 A 48 to 65 Hz 48 Hz to 65 Hz 40 Hz to 40 kHz 20 mm (0.8 in) 40 Hz to 40 kHz 20 mm (0.8 in) 5 kHz to 20 kHz 32 mm (1.25 in) 5 Hz to 10 kHz 32 mm (1.25 in) 30 Hz to 10 kHz (typical) 54 mm (2.13 in) Maximum conductor size 300 MCM 300 MCM 750 MCM 750 MCM 2-500 MCM or 2-500 MCM or 1-1000 MCM 1-1000 MCM Output levels 1 mA/A 10 mV/A 100 mV/A 1 mA/A 10 mV/A 1 mV/A 1 mA/A Output cable 1.5 m shrouded banana plugs 2 m to BNC termination 1.5 m shrouded banana plugs 2.5 m to BNC termination 1.6 m shrouded banana plugs Warranty Safety rating One-year CAT III 600 V One-year CAT III 600 V One-year CAT III 1000 V CAT IV 600 V One-year CAT III 1000 V CAT IV 600 V Maximum conductor diameter 10 Hz to 10 Hz to 100 kHz 20 kHz 64 x 100 mm 177 mm (7 in) (2.52 x 3.94 in) 64 mm (2.52 in) 10 Hz to 50 kHz 177 mm (7 in) or 265 mm (10.4 in) 610 mm or 915 mm circumference 100 mV/A 10 mV/A 1 mV/A 2.1 m to BNC termination 1 mV/A 10 mV/A 100 mV/A 1.6 m to BNC termination 10 mV/A 1 mV/A 0.1 mV/A 2.1 m to BNC termination One-year CAT III 600 V One-year CAT III 600 V One-year CAT III 600 V 610 mm (24 in) circumference 100 mV/A 10 mV/A 1 mV/A 2 m with double shrouded banana plugs One-year CAT III 600 V i800 i1000s 0.1 A to 1000 A* 3 A to 1000 A* 0.6 A to 1000 A* 0.6 A to 1000 A* 0.1 A to 1000 A* 0.2 A to 1000 A* 0.1 A to 1000 A* 0.6 A to 1000 A* 0.1 A to 1000 A* 0.2 A to 1000 A* 0.1 A to 1000 A* 0.3 A to 1000 A* 0.3 A to 1000 A* 0.1 A to 1000 A* 0.2 A to 1000 A* 0.1 A to 1000 A* 0.2 A to 1000 A* 0.2 A to 1000 A* 0.3 A to 1000 A* 0.1 A to 1000 A2 0.1 A to 1000 A 0.3 A to 1000 A 0.1 A to 1000 A 0.25 A to 1000 A 0.1 A to 1000 A 0.15 A to 1000 A* i3000s 1 A to 3000 A 30 A to 3000 A 1 A to 3000 A 1 A to 3000 A 1 A to 3000 A 2 A to 3000 A 1 A to 3000 A 1 A to 3000 A 1 A to 3000 A 2 A to 3000 A 1 A to 3000 A 3 A to 3000 A 3 A to 3000 A 1 A to 3000 A 2 A to 3000 A 1 A to 3000 A 1 A to 3000 A 2 A to 3000 A 3 A to 3000 A 1 A to 3000 A2 1 A to 3000 A 1.2 A to 3000 A 1 A to 3000 A 2.5 A to 3000 A 1 A to 3000 A 1.5 A to 3000 A i2000 Flex1 2 A to 2000 A 3 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A2 2 A to 2000 A Best to use i430Flex 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A i3000s Flex 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A2 3 A to 3000 A Best to use i430Flex 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 0.1 A to 1000 A* 0.2 A to 1000 A* 1.1 A to 1000 A* 0.2 A to 1000 A* 1 A to 3000 A 1 A to 3000 A 11 A to 3000 A 2 A to 3000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A i200s i400 One-year CAT III 600 V AC current clamp selection guide Meter 10/11/12/12B/16/18 i200 110/111/112 114/116 115/117 21/23/73/75/77 Series III 26/79 Series III 27 233 27II 28II 60 A to 200 A 1 A to 200 A 1 A to 40 A 1 A to 200 A 60 A to 200 A 2 A to 200 A 1.8 A to 200 A 70 Series III 175/177/179 1577/1587 Insulation Meter 83III/83V/88V 85/87 Series III 87 Series V 87/89 Series IV 187/189 287/289 8060A/8062A DMMs 860 Series Graphical Multimeters 39/41B Power Meter 43B Power Quality Analyzer 434/435 Power Quality Analyzer 9X ScopeMeter Series 120 Series ScopeMeters 190 Series Scopemeters 45 DMM 8808A 8845A/8846A 74X Series Process Calibrators 787/789 Process Meters 3 A to 200 A 3 A to 200 A 2 A to 200 A 2 A to 200 A 2.5 A to 200 A 1 A to 200 A 2 A to 200 A 1 A to 200 A 1.5 A to 100 A 1 A to 200 A 1 A to 200 A 50 A to 200 A i200s 1 A to 200 A 3 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A2 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1 A to 200 A 1.1 A to 200 A 1 A to 200 A i400 60 A to 400 A 1 A to 400 A 1 A to 40 A & 200 A to 400 A 1 A to 400 A 60 A to 400 A 2 A to 400 A 1.8 A to 400 A 3 A to 400 A 3 A to 400 A 2 A to 400 A 2 A to 400 A 2.5 A to 400 A 1 A to 400 A 2 A to 400A 1 A to 400 A 1.5 A to 100 A 1 A to 400 A 1 A to 400 A 50 A to 400 A i400s 1 A to 400 A* 30 A to 400 A* 0.6 A to 400 A* 0.6 A to 400 A* 1 A to 400 A* 2 A to 400 A* 1 A to 400 A* 0.6 A to 400 A* 1 A to 400 A* 1.8 A to 400 A 1 A to 400 A* 1 A to 400 A* 3 A to 400 A* 1 A to 400 A* 2 A to 400 A* 1 A to 400 A* 0.5 A to 400 A* 2 A to 400 A* 3 A to 400 A* 1 A to 400 A2 0.35 A to 400 A 1.2 A to 400 A 1 A to 400 A 2.5 A to 400 A 1 A to 400 A 1.5 A to 400 A* 0.5 A to 400 A* 1 A to 400 A* 11 A to 400 A* 2 A to 400 A* 60 A to 800 A 1 A to 800 A 1 A to 40 A & 200 A to 800 A 1 A to 800 A 60 A to 800 A 2 A to 800 A 1.8 A to 800 A 3 A to 800 A 3 A to 400 A 2 A to 800 A 2 A to 800 A 2.5 A to 800 A 1 A to 800 A 2 A to 800 A 1 A to 800 A 1.5 A to 100 A & 500 A to 800 A 1 A to 800 A 1 A to 800 A 50 A to 440 A * Requires PM9081/001 Adapters. 1 Three range version. 2 Current and watt readings will be multiples of 10 higher or lower than actual on some ranges. 60 Accessories i800 i1000s i2000 Flex i3000s Flex i6000s • 6 A to 6000 A • Compatible with most products except 434/435 For more information, go to www.fluke.com/accessories Fluke current clamps For use with multimeters, ScopeMeters and power quality analyzers AC/DC current clamp specifications 80i-110s AC/DC models i410 i1010 i30 i30s i310s 0.1A to 450A DC range 0.1 A to 100 A 1 to 400 A 1 to 1000 A 30 mA to 30 A 30 mA to 30 A AC range 0.1 A to 70 A 1 A to 400 A 1 A to 600 A 30 mA to 20 A rms 30 mA to 20 A rms 0.1A to 300A ± 1 % of reading, ± 2 mA ± 1 % of reading, ± 2 mA 30 A range: 1 % + 50 mA 300 A range: 1 % + 300 mA Accuracy Bandwidth (-3 dB) 0.1 A to 10 A; dc to 3.5 % + 0.5 A for dc or 2 % + 0.5 A for dc or ac 1 kHz: ± 3 % + 50 mA; ac (45 to 400 Hz) (45 to 400 Hz) up to 100 A add 15 %; up to 20 kHz add 12 % 100 kHZ 3 kHz 10 kHz Zero error adjustment Yes Yes Yes Yes Yes Yes Maximum conductor diameter 11.8 mm (0.46 in) 30 mm (1.18 in) 30 mm (1.18 in) 19 mm (0.75 in) 19 mm (0.75 in) 19 mm (0.75 in) Maximum conductor size dc to 20 kHz (-0.5 dB) dc to 100 kHz (-0.5 dB) DC to 20 kHz 1 AWG 750 MCM or 2-500 MCM 750 MCM or 2-500 MCM 250 MCM 250 MCM 250 MCM Output levels 10 mV/A, 100 mV/A 1 mV/A 1 mV/A 100 mV/A 100 mV/A 1 mV/A, 10 mV/A Output cable 1.6 meter with BNC termination 1.2 meter with shrouded banana plugs 1.2 meter with shrouded banana plugs 1.5 meter with shrouded dual banana plue 2 meter with BNC termination 2 meters with BNC terr mination and a BNC to safety shrouded banana adapter Battery life 40 hours 60 hours 60 hours 30 hours 30 hours 30 hours Warranty One-year One-year One-year One-year One-year One-year CAT II 600 V; CAT III 300 V CAT III 600 V CAT III 600 V CAT III 300 V CAT III 300 V CAT III 300 V Safety i410 AC/DC current clamp selection guide Meter 80i-110s i410 i1010 i30 i30s i310s 10/11/12/12B/16/18 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 5 A to 400 A dc/ 7 A to 400 A ac 5 A to 1000 A dc/ 7 A to 600 A ac 40 mA to 30 A dc/ 60 mA to 20 A ac 40 mA to 30 A dc/ 60 mA to 20 A ac 0.4 A to 450 A dc/ 0.6 A to 300 A ac 110/111/112 0.14 A to 100 A dc/ 3 A to 70 A ac* 5 A to 400 A dc/ 300 A to 400 A ac 5 A to 1000 A dc/ 300 A to 600 A ac 40 mA to 30 A dc/ 3 A to 20 A ac 40 mA to 30 A dc/ 3 A to 20 A ac 0.4 A to 450 A dc/ 30 A to 300 A ac 114/115/116/117 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1.4 A to 400 A dc/ 6 A to 400 A ac 1.4 A to 1000 A dc/ 6 A to 600 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 0.1 A to 450 A dc/ 0.6 A to 300 A ac 21/23/70/73/75/77 Series III 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 5 A to 400 A ac 1 A to 1000 A dc/ 5 A to 600 A ac 30 mA to 30 A dc/ 40 mA to 20 A ac 30 mA to 30 A dc/ 40 mA to 20 A ac 0.1 A to 450 A dc/ 0.4 A to 300 A ac 26/79 Series III 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 20 A to 400 A ac 1 A to 1000 A dc/ 20 A to 600 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac 233 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1.4 A to 400 A dc/ 6 A to 400 A ac 1.4 A to 1000 A dc/ 6 A to 600 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 0.1 A to 450 A dc/ 0.6 A to 300 A ac 27 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 27II 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 28II 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 6 A to 400 A ac 1 A to 1000 A dc/ 6 A to 600 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac 77-IV 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 5 A to 400 A ac 1 A to 1000 A dc/ 5 A to 600 A ac 30 mA to 30 A dc/ 40 mA to 20 A ac 30 mA to 30 A dc/ 40 mA to 20 A ac 0.1 A to 450 A dc/ 0.4 A to 300 A ac 175/177/179 0.11 A to 100 A dc/ 0.3 A to 70 A ac* 1.6 A to 400 A dc/ 30 A to 400 A ac 1.6 A to 1000 A dc/ 30 A to 600 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 0.1 A to 450 A dc/ 3 A to 300 A ac 1577/1587 Insulation Meter 0.1 A to 100 A dc/ 0.3 A to 70 A ac* 1.2 A to 400 A dc/ 30 A to 400 A ac 1.2 A to 1000 A dc/ 30 A to 600 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 0.1 A to 450 A dc/ 3 A to 300 A ac 83-III/83-V/88-V 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 85-III/87-III/87-V 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 20 A to 400 A ac 1 A to 1000 A dc/ 20 A to 600 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac 87-IV/89-IV/ 187/189 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 2.5 A to 400 A ac 1 A to 1000 A dc/ 2.5 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.25 A to 300 A ac 287/289 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 8060A/8062A DMMs 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 20 A to 400 A ac 1 A to 1000 A dc/ 20 A to 600 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac 860 Series Graphical Multimeters 80i-110s 0.1 A to 100 A dc/ 0.3 A to 70 A ac* 1 A to 400 A dc/ 30 A to 400 A ac 1 A to 1000 A dc/ 30 A to 600 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 0.1 A to 450 A dc/ 3 A to 300 A ac 39/41B Power Meter Usable but will read 10 or 100 times higher 1 A to 400 A ac** Not spec’d for dc 1 A to 600 A ac** Not spec’d for dc Usable but will read 100 times higher** Usable but will read 100 times higher Not spec’d for dc 0.6 A to 300 A ac 9X ScopeMeter Series 0.1 A to 100 A dc/ 0.1 A to 70 A ac 1 A to 400 A dc/ 5 A to 400 A ac** 1 A to 1000 A dc/ 5 A to 600 A ac** 30 mA to 30 A dc/ 50 mA to 20 A ac** 30 mA to 30 A dc/ 50 mA to 20 A ac 0.1 A to 450 A dc/ 0.5 A to 300 A ac 123/124 ScopeMeters 0.1 A to 100 A dc/ 0.25 A to 70 A ac 1 A to 400 A dc/ 25 A to 400 A ac** 1 A to 1000 A dc/ 25 A to 600 A ac** 30 mA to 30 A dc/ 250 mA to 20 A ac** 30 mA to 30 A dc/ 250 mA to 20 A ac 0.1 A to 450 A dc/ 2.5 A to 300 A ac 190 Series Scopemeters 0.1 A to 100 A dc/ 0.1 A to 70 A ac 1 A to 400 A dc/ 5 A to 400 A ac** 1 A to 1000 A dc/ 5 A to 600 A ac** 30 mA to 30 A dc/ 50 mA to 20 A ac** 30 mA to 30 A dc/ 50 mA to 20 A ac 0.1 A to 450 A dc/ 0.5 A to 300 A ac 45 DMM 0.1 A to 100 A dc/ 0.15 A to 70 A ac* 1 A to 400 A dc/ 15 A to 400 A ac 1 A to 1000 A dc/ 15 A to 600 A ac 30 mA to 30 A dc 150 mA to 20 A ac 30 mA to 30 A dc 150 mA to 20 A ac 0.1 A to 450 A dc/ 1.5 A to 300 A ac 8808A 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 2 A to 400 A ac 1 A to 1000 A dc/ 2 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.2 A to 300 A ac 8845A/8846A 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 705/707 0.1 A to 100 A dc, No ac* 4 A to 400 A dc, No ac 4 A to 1000 A dc, No ac 40 mA to 30 A dc, No ac 40 mA to 30 A dc, No ac 0.4 A to 450 A dc, No ac 715 0.1 A to 100 A dc, No ac* 4 A to 400 A dc, No ac 4 A to 1000 A dc, No ac 40 mA to 30 A dc, No ac 40 mA to 30 A dc, No ac 0.1 A to 450 A dc, No ac 74X Series Process Calibrators 0.1 A to 100 A dc/ 1.1 A to 70 A ac* 1 A to 400 A dc/ 110 A to 400 A ac 1 A to 1000 A dc/ 110 A to 600 A ac 30 mA to 30 A dc/ 1.1 A to 20 A ac 30 mA to 30 A dc/ 1.1 A to 20 A ac 0.1 A to 450 A dc/ 11 A to 300 A ac 787/789 Process Meters 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 20 A to 400 A ac 1 A to 1000 A dc/ 20 A to 600 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 3 mA to 30 A dc/ 200 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac i1010 i310s, i30s and i30 Hall Effect AC/DC Current Clamps • Especially useful for low current measurements down to 30 milliamps i310 i30s i30 * Requires PM9081 Adapter ** Requires PM9082/001 Adapter ***Only for use with the 430 Series Power Quality Analyzers For more information, go to www.fluke.com/accessories Accessories 61 Fluke lights and hangers Free your hands and shed light on the contact point LVD1 Volt Light • Exclusive dual-sensitivity • Detects voltages from 40 V ac to 300 V ac • Voltage detector glows blue at 50 Hz to 60 Hz or 2.5 cm to 38 cm (1 in to 5 in) away from source • Ultra-bright white LED with 100,000 hour bulb life • AAA battery included L206 Deluxe LED Hat Light (hard hat not included) Attach it to a hard hat, a baseball cap, or even a panel door for all the light you need. • Three super bright white LEDs—never burn out • Special hard-hat attachment included • 40-hour battery life • Includes three AAA batteries L210 Probe Light and Probe Extenders • 8 inch probe extenders fit modular test probes • Probe and extender length complies with NFPA recommendations • Bright white LED illuminates contact area • Probe light fits on extender or test probe LVD2 Volt Light • Non-contact ac voltage detector and bright white LED flashlight • Detects voltage from 90 V to 600 V ac from 1 to 5 inches away • CAT IV rated, one-year warranty L205 Mini Hat Light Rugged, high-intensity Xenon worklight. • Attaches to a baseball cap • Includes a hat clip • Includes two AAA batteries • Waterproof 62 Accessories TPAK ToolPak™ Magnetic Meter Hanger L215 SureGrip™ Kit with Probe Light and Probe Extenders • L200 probe light • TP220 SureGrip test probes • TL224 SureGrip test leads • TP280 test probe extenders • Soft foldable pouch, keeps the entire set together • Free both hands to make measurements • Hang your meter from metallic surfaces like panels and pipes • Kit includes universal hanger clips (two), hook and loop straps (two lengths), adapter and strong magnet • Attaches to back of many Fluke meters, including 110, 170, 180, 280 Series, 87V and 83V DMMs, 724, 725 and 789 Process Calibrators, 70 Series III DMMs, 1503, 1507, 1577 and 1587 Insulation Multimeters and 50 Series II Digital Thermometers For more information, go to www.fluke.com/accessories Specialty accessories and software Get more out of your multimeter Stray voltage Fiber optics SV225 • Eliminates stray voltage due to capacitance between wires in electrical installations • Compatible with all instruments and test lea that accept standard 4 mm shrouded banana connectors FOM Fiber Optic Meter The Fluke Fiber Optic Meter (FOM) helps you test and maintain fiber optic cable without having to buy a whole new meter. Plug the FOM directly into any DMM with a mV dc funtion and a 10 mW input impedance, and quickly and accurately verify fiber optic cable system loss. Light sources and patch cords sold separately. Pressure and vacuum PV350 Pressure Vacuum Module • Digital pressure and vacuum measurements in a single module • Measures HVAC/R, hydraulic and pneumatic pressu to 350 psig/2413 to 500 psig) • Measures to 76 cm Hg (29.9 in Hg) vacuum (not intended for measuring microns of vacuum) • Compatible with most digital multimeters Logging software FOS 850 and FOS 850/1300 Fiber Optic Light Sources A variety of LED light sources allow you to test different cables. FlukeView® Forms Harness the power of the data logging function on your Fluke Digital Multimeter, Thermometer or ProcessMeter. Log live readings while connected to a PC, or leave your Fluke 289, 789 or 54-II in place to capture up to 1,000 readings for download to a PC. Choose the model that’s right for you: • FVF-SC2: Includes software and cable used with 280 Series DMMs and 789 ProcessMeters, and the 1550B Insulation Tester • FVF-SC3: Includes software and cable used with 45 Bench Meters • FVF-SC4: Includes software and cable used with 8845A and 8846A Multimeters Fuse selection guide Replacement fuses for Fluke DMMs are available from your distributor. To order direct from Fluke call 1-800-44-FLUKE (U.S.) or email fluke-info@fluke.com. Go to www.fluke.com/flukeviewforms to download the demo. FlukeView® Forms Basic An abridged version of FlukeView Forms. • Available for use with 280 Series DMMs and 789 ProcessMeters, only • Upgrade to the full FlukeView Forms with FVF-UG • Compatible with the 280 and 789 series only 1577 1587 787/789 744 • 741/743 • 725/726 •* • 43B • • 715 287/289/187/189 • • 83V • 233 • • 87V 179 • • FlukeView Forms Software TPak 87/89 IV 175/177 80 Series III/83V 70/73 III • 27 II/28 II/27 114/115/116/117 • 20/70 Series 110/111/112 Selection Guide 10/11/12/12B 83-III/85-III/87-III 87-IV/89-IV/187/189/287/289/77III/79-III/23-III/26-III/175/177/179/77-IV/27-II/28-II 111/112/115/117/233 1577/1587 1503/1507 787/789 705/707 83/85/87 (S/N>6565000) 51/52/53/54 II 27 (S/N>7247001 190 Series 27 (S/N<7247001) 120 Series Fuse Requirements P/N 871173 630mA 250V fuse P/N 803293 11A 1000V fuse P/N 871173 630mA 250V fuse P/N 871202 3A 600V fuse P/N 892583 15A 600V fuse P/N 943121 440mA 1000V fuse P/N 803293 11A 1000V fuse P/N 943121 440mA 1000V fuse P/N 803293 11A 1000V fuse P/N 943121 440mA 1000V fuse P/N 803293 11A 1000V fuse P/N 803293 11A 1000V fuse P/N 943121 440mA 1000V fuse P/N 2279339 315mA 1000V fuse P/N 943121 440mA 1000V fuse (Qty 2) 90 Series Model 21-III/75-III/73-III 789 • 789 • • • • PV350 (pressure) • • • • • • • • • • • • • • • • • • • • • • FOM (fiber optic) • • • • • • • • • • • • • • • • • • • • • • CO-210 • • • • • • • • • • • • • • • • • • • • • • *53 B II, 54 B II only. For more information, go to www.fluke.com/accessories Accessories 63 Your authorized Fluke distributor Join the conversation We design our products with you in mind. Yeah, we have guys in lab coats, developing and testing our tools in rooms we dare not enter. But our ideas, the things that drive our intense development process, come straight from the job site—from pros like you. You are the voice of Fluke’s innovation. Tell us what you think. Visit our social media sites, and get the conversation started. We’re listening. More Fluke info online • Complete digital catalog • Measurement safety • Newest products • • • • Where to buy Extended specs Online Store How-to information www.fluke.com/catalog www.facebook.com/fluke.corporation Contact us: www.twitter.com/flukecorp www.youtube.com/flukecorporation United States General product and sales information: 1-800-44-FLUKE fluke-info@fluke.com Fluke Thermal Imagers: 1-800-760-4523 (U.S. only) all other regions 1-425-446-4620 Service and calibration: 1-888-99-FLUKE Parts: 1-800-526-4731 Canada General product, sales, service, parts and calibration information: 1-800-36-FLUKE canada@fluke.com Australia General product and sales information: (02) 8850-3333 Parts: (02) 8850-3333 Service and calibration: (02) 9771-9300 Fluke. Keeping your world up and running.® Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands Singapore General product and sales information: (65) 6799-5566 info.asean@fluke.com Service, parts and calibration: (65) 6799-5588 service.asean@fluke.com For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com Japan General product and sales information: +81-3-3434-0181 Service, parts and calibration: +81-3-3434-0188 ©2003-2011 Fluke Corporation. Specifications subject to change without notice. Microsoft is a registered trademark of Microsoft Corporation. Printed in U.S.A. 12/2010 1274458S C-US-N Volume 41 Other countries: 1+(425) 446-5500 Modification of this document is not permitted without written permission from Fluke Corporation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Owner Create Date : 2011:10:19 22:48:01-04:00 Modify Date : 2012:04:03 11:24:17-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Metadata Date : 2012:04:03 11:24:17-04:00 Document ID : uuid:56d3c0f1-35bb-458c-94c2-a23fee56b2dd Instance ID : uuid:ce47856d-e9d6-4e4f-a8a7-d7a44e0cf37a Format : application/pdf Title : 1274458_6003_ENG_S_W.pdf Creator : Owner Page Count : 65EXIF Metadata provided by EXIF.tools