1274458_6003_ENG_S_W 113782 Catalog

2014-07-05

: Pdf 113782-Catalog 113782-Catalog 095969 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 65

Keeping your world
up and running.
Test Tools Catalog
Volume 41, 2011
Fluke 381 Remote Display
Clamp Meter with iFlex
Part of Fluke’s new family of clamp meters,
the Fluke 381 Clamp Meter combines iFlex
flexibility with remote reading capability—the
best of both worlds.
Remote display reads measurements
up to 30 feet away
Measure up to 2500 A ac with the iFlex flexible
current probe
1000 A ac and dc current measurement
with fixed jaw
1000 V ac and dc voltage measurement
Min/Max/Avg and inrush recording
CAT IV 600 V, CAT III 1000 V
For information on the new 381 Remote Display
Clamp Meter with iFlex see page 4.
Fluke 810 Vibration Tester
The Fluke 810 Vibration Tester is the most
advanced troubleshooting tool for mechanical
maintenance teams who need an answer now.
Utilizes a simple step-by-step process to
report on machine faults, without needing
prior measurement history
On-board identification and location of
most common mechanical faults: bearings,
misalignment, unbalance, looseness
2 GB expandable on-board memory
Four-level fault severity scale
Tri-axial accelerometer reduces measurement
time by 2/3 over single axis accelerometers
For information on the new 810 Vibration Tester
see page 52.
Powerful
vibration
testing
Remote
display
and iFlex
Whats new
1555 Insulation Resistance Tester
From motors and generators to cables and
switchgear, Fluke now takes you all the way
to 10 kV.
Ideal for testing a wide range of high voltage
equipment
Automatic calculation of Dielectric Absorption
(DAR) and Polarization Index (PI) with no
additional setup
Long battery life allows for over 750 tests
between charges
Measurements can be stored in up to 99
memory locations, with each location assigned
a unique, user defined label for easy recall
For information on the new 1555 Insulation Resistance
Tester see page 25.
TiS Building Diagnostic
Thermal Imaging Scanner
Finally! An entry level thermal imager for quick,
easy and accurate problem identification and
troubleshooting, designed specifically for the
building inspection professional.
Most affordable thermal imager on the market
that meets proposed RESNET infrared inspection
standard
120 x 120 resolution
Large, 3.7 inch display–30 percent larger than
comparable imagers
Rugged body withstands 2 m (6.5 ft) drop test
Award winning ergonomic design
For information on the new TiS Thermal Imager
see page 47.
10 kV
Ranges
up to
30%
larger
Display
2AC VoltAlert Voltage Tester
2AC is the latest addition to the VoltAlert ac non-
contact voltage tester family from Fluke, and is designed
to be pocket-sized and easy to use. The 2AC tests for
energized circuits and defective grounds. The tip of the
pocket-sized tester will glow red if voltage is present.
Voltage detection from 90 V ac to 1000 V ac
Always on, using special low power circuitry
to sustain battery life and ensure your 2AC
is always ready
Innovative ‘Battery Check’ button function ensures
battery is in good condition
CAT IV 1000 V overvoltage rated product
for best in class user protection
For information on the new 2AC VoltAlert see page 21.
190 Series II ScopeMeter®
Portable Oscilloscopes
Multiply your diagnostic powers with the first
CAT III 1000 V/CAT IV 600 V rated, four-channel
portable scope on the market. The new Fluke 190
Series II brings an unprecedented combination of
performance and ruggedness into the field.
Fast sample rate: up to 2.5 GS/s with up to
400 ps resolution
Deep memory: 10,000 point per trace
waveform capture
Single shot, pulse width and video triggering
Seven-hour, high-performance Li-ion battery is
standard
Two isolated USB ports for memory devices and
PC connectivity
For information on the new 190 Series II ScopeMeter
see page 42.
4
channel
testing
Battery
check
button
51
IR-Windows
3
www.fluke.com
Test Tools Catalog
Volume 41, 2011
Contents
4
Clamp
Meters
19
Earth Ground
Testers
24
Insulation
Resistance Testers
52
Vibration Tester
18
Distance
Meters
22
Indoor Air
Quality Tools
31
Process
Calibration Tools
49
Thermometers
8
Digital
Multimeters
21
Electrical
Testers
26
Power Quality
Analyzers
44
Thermal
Imaging Tools
53
Accessories
Fluke Corporation is the world
leader in compact, professional
electronic test tools.
From industrial
maintenance
to commercial
building operations,
Fluke tools deliver
the testing and
troubleshooting
capabilities to keep
global commerce
and industry up
and running.
Fluke customers
are technicians,
engineers,
electricians, and
building diagnostics
professionals—
people who stake
their reputations on
their tools.
40
ScopeMeter®
Test Tools
4
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fluke.com/wtb-clam
ps
www.fluke.com/wtb-clam
ps
Join the conversation!
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/clamp
s
Clam
p
Meters
u
e 381 Remote D
s
a
True-rms
AC/DC Clamp Meter with iFlex
x
x
A
ll the
b
ell
s
and whi
s
tle
s
T
he Fluke 3
8
1 Clamp Meter combines
i
Flex flexibility with remote reading
c
apability for the ultimate in innov
a
-
t
ion and safety.
R
emote
di
sp
l
ay rea
d
s measurements
up to
30
feet awa
y
i
Flex flexible current probe
i
ncluded
,
1
8
-inch circumference
2
5
00
A ac current measurement
wi
t
h
iFl
ex
1000
A ac and dc curret measure
-
m
ent with fixed jaw
1000
V ac and dc voltage
m
easuremen
t
F
requency measurement to 5
00
H
z
60
k
resistance measuremen
t
M
in
/
Max
/
Avg and inrush recording
C
AT IV
600
V
,
C
AT III 1
000
V
Th
ree-year warranty
S
ee specifications chart on page 7.
Fl
u
k
e 365 Detac
h
a
bl
e Jaw
True-rms AC/DC Clamp Meter
Wh
ere rugge
d
meets re
li
a
ble
T
he Fluke 365 Clamp Meter offers a small,
d
etachable
j
aw—with four feet of coil—that
m
a
k
es
i
t eas
y
to ta
k
e an
d
rea
d
measurements
i
n
tigh
t or
h
ar
d
-to-reac
h
p
l
aces
.
200
A ac and dc current measurement
6
00 V ac and dc volta
g
e measuremen
t
6000
Ω resistance measuremen
t
B
uilt-in flashli
g
ht
L
ar
g
e, eas
y
-to-rea
d
b
ac
kligh
t
di
sp
l
a
y
Th
ree-
y
ear warrant
y
See speci
f
ications chart on page 7.
Ordering information
Included accessories Models
1
8
-inch iFlex
Flexible
C
urrent
P
robe, test leads, soft carrying
case, instruction card, sa
f
et
y
i
n
f
ormation sheet
,
f
ive AA
alkali
ne
ba
tter
i
e
s.
FLUKE-3
81
Remote Display True-rms AC/DC Clamp Meter with iFlex
T
est leads, so
f
t carrying
case, instruction card, safety
i
n
f
ormation sheet
,
f
ive AA
alkaline batteries
.
FLUKE-3
65
D
etachable Jaw True-rms AC/DC Clam
p
Mete
r
True
RMS
True
RMS
Recommended accessories
3D virtual
demos
W
a
nt t
o
s
ee the
F
luke
3
7
6
and
F
luke 3
8
1 Clamp
M
eters up close
a
nd personal
?
Visit
w
ww.fluke.com
/
c
lamp
f
amil
y
for links to two
3
D
virtu
a
l dem
os
.
Mobile resources
W
e
ve create
d
i
nteract
i
ve messa
g
-
i
n
g
b
oar
d
s
d
e
di
cate
d
t
o
di
scuss
i
n
g
a
ll
thi
n
g
s c
l
amp meter.
Give us a shout
,
start a
di
scuss
i
on or
p
art
i
c
ip
ate
i
n a
p
o
ll
we
re ea
g
er to
h
ear
y
our t
h
ou
gh
ts.
Vi
s
i
t
www.fluke.com
/
readyforanythin
g
Fl
u
k
e c
l
amp meters are
g
o
i
n
g
mo
bil
e.
Vi
s
i
tm.
f
luke.co
m
from an
y
smartphone for
o
n-t
h
e-
g
o t
i
ps
,
videos and inf
o
re
g
ar
di
n
g
our
newest c
l
amp
me
t
ers.
i
2500
-1
0
i
2500
-1
8
10
inch iFle
x
Fl
e
xi
b
l
e
1
8
inch iFle
x
Fl
e
xi
b
l
e
C
urrent Pr
o
b
e
C
urrent Pr
o
b
e
S
ee pa
g
e
5
S
ee pa
g
e
5
TL223
TL223
TL71
S
ureGri
p
Electrical
P
remium
T
e
s
t Le
a
d
S
et
T
e
s
t Le
a
d
S
e
t
S
ee
p
a
ge
57
S
ee
p
a
ge
57
5
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fluke.com/wtb-clam
ps
www.fluke.com/wtb-clam
ps
iFlex Flexible Current Probe
F
or more in
f
ormation,
g
o to www.fluke.com/clamps
C
lam
p
Meters
F
luke 370 Series Clam
p
Meters
Be ready for anything
O
ur new family of true-rms clamp meters
p
rovides a range o
f
state o
f
-the-art
f
ea
-
u
res to meet even the most demandin
g
o
b requirements.
A
ll
f
our o
f
the new clamp meters have
m
proved base
f
eatures such as a large,
b
acklit display, true-rms standard,
C
AT IV
af
ety rating and a durably constructed
b
ody. Additionally, the
3
7
6
,
3
75 and
3
74
a
re compatible with the iFlex
f
lexible
urrent probe
(
included with the 376,
o
ld separately for the
3
75 and
3
74
)
, and
p
rovide increased measurement readings
o
1
000
A and 1
000
V ac and dc
.
S
ee specifications chart on pa
g
e 7 for
d
etails per model
.
Ordering information
Included accessories Models
18-inch iFlex
flexible
c
urrent
p
robe, test leads, soft carr
y
in
g
case, instruction card, sa
f
et
y
i
nformation sheet, two AA
alkali
ne
ba
tter
i
e
s.
FLUKE-37
6
T
rue-rms AC
/
DC Clamp Meter with iFlex
T
est leads, soft carrying
case, instruction card, safet
y
i
n
f
ormation sheet
,
two AA
a
lk
a
line b
a
tterie
s.
FLUKE-37
5
True-rms AC
/
DC Clamp Meter
Test leads, so
f
t carrying
c
ase, instruction card, safety
in
f
ormation sheet
,
two AA
a
lkaline batteries.
F
LUKE-374 True-rms AC/DC Clam
p
Mete
r
Test leads, so
f
t carr
y
in
g
case, instruction card, safety
i
nformation sheet, two AA
alkaline batteries
.
FLUKE-
3
7
3
T
rue-rms A
C
C
lam
p
Mete
r
U
n
p
rece
d
ente
d
m
easurement
f
lexibility
.
The new iFlex
f
lexible current probe
expands the measurement range o
f
select Fluke clamp meters to
2
5
00
A
a
c w
hil
e prov
idi
ng
i
ncrease
d
di
sp
l
ay
f
lexibility, improved wire access and
th
e a
bili
ty to measure aw
k
war
d
-s
i
ze
d
co
n
d
u
c
t
o
r
s
.
A
vailable in 1
8
-inch and 10-inch
coil
si
ze
s
.
Visi
t
w
ww.fluke.com
/
iFlex-18
f
or additional specs
.
Old model New model Feature changes
Fluke 337 Fl
u
k
e
376 Includes all
33
7 features plus:
CAT IV 600 V, CAT III 1000 V
iFlex 2500 A ac
1000 V ac/dc
mV dc
60 kΩ
1000 µF
Fluke 336 Fl
u
k
e
37
5
Includes all
336
features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
mV dc
60 kΩ
1000 µF
Min/Max/Avg
Fl
u
k
e
374 Includes all 336 features (except low pass filter) plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
1000 µF Min/Max/Avg
Fluke 335 Fl
u
k
e
374 Includes all
33
5 features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
600 A ac/dc
1000 µF
Min/Max/Avg
Fl
u
k
e
3
7
3
Includes all 335 features (except inrush) plus:
CAT IV 300 V, CAT III 600 V 1000 µF
Fluke 334 Fluke
3
74 Includes all 334 features
p
lus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex 2500 A ac
True-rms
600 A ac/dc
1000 µF
Min/Max/Avg
Fluke
3
7
3
Includes all 334 features
(
exce
p
t inrush)
p
lus:
CAT IV 300 V, CAT III 600 V True-rms 1000 µF
Fluke 333 Fluke 37
3
Includes all
333
features
p
lus:
CAT IV 300 V, CAT III 600 V
True-rms
600 A ac
6000
1
000
µF
Quick reference guide conversion table
ke
uke 373
True
RMS
Recommended accessories
AC285
TL175
S
ure
G
ri
p
Alli
gator
T
wist
G
uard
C
lips
T
e
s
t
L
e
ads
See
page
57
See
page
57
TL223
TL223
TL71
SureGri
p
El
ectr
i
ca
l
P
r
e
m
iu
m
T
est Lead Set
T
est Lead Se
t
S
ee
p
a
ge
57
S
ee
p
a
ge
57
i2500
-
10
i2500 18
10
inch iFlex
Fle
x
ible
18 inch iFle
x
Fle
x
ible
C
urrent Prob
e
C
urrent Prob
e
See
page
5
S
ee
page
5
6
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Application note
Recommended accessories
True
RMS
F
luke 320 Series
C
lamp Meter
s
G
et more don
e
T
he Fluke
32
1 and
322
are designed
to verify the presence of load current,
ac voltage and continuity of circuits,
s
witches
,
fuses and contacts. These
s
ma
ll
an
d
rugge
d
c
l
amp meters are
id
e
-
ally suited for current measurements up
to 4
00
A in tight cable environments.
Precised measurements with 1.
8
%
b
as
i
c accurac
y
R
esolution up to
0
.
0
1 A and
0
.1 V
M
easures ac current 40.00 A
/
400.0
A
M
easures ac and dc volts to
600
V
R
esistance measurement to 4
00
C
ontinuity for quick checking of shorts
See specifications chart on page 7 for
d
eta
il
s per mo
d
e
l.
F
luke 902 True-rms HVAC
C
lamp Meter
Just for our HVA
C
p
ros
HVAC
(
heating, ventilation, air conditioning) technicians
requ
i
re a serv
i
ce too
l
t
h
at can cons
i
stent
l
y
k
eep up w
i
t
h
their demands. The Fluke
902
expands the existing line of
q
uality Fluke clamp meters by delivering the features neces
-
s
ary to diagnose and repair HVA
C
systems.
C
ombined with
true-rms technology and a
C
AT III
600
V rating, the Fluke
902
helps technicians do their jobs safely and accurately.
Designed for HVA
C
applications with capacitance, dc
c
urrent
(
µA), and temperature measurement
s
S
mall body and jaws fit perfectly in your hand and into
t
i
g
h
t p
l
ace
s
H
an
d
y
“Di
sp
l
ay
H
o
ld”
b
utton
k
eeps measurements on t
h
e
di
sp
l
a
y
M
eter contro
l
s are pos
i
t
i
one
d
so current measurements can
b
e done with one hand
(
index finger on clamp opening
l
ever and thumb on rotary switch
)
Th
ree-year warranty
See specifications chart on page 7.
Ordering information
Included accessories Models
T
est leads, so
f
t carr
y
in
g
case, instruction card, sa
f
et
y
i
n
f
ormation sheet
,
two AA alkaline batteries
.
FLUKE-
32
1
C
lamp Meter
FLUKE-322 Clam
p
Meter
Test leads, temperature probe, soft carrying case, users
m
anua
l
, two
AA
a
lk
a
li
ne
b
atter
i
es.
F
LUKE-9
0
2True-rms HVAC Clam
p
Mete
r
S
oft carrying case, instruction card, safety information
sheet
,
f
ive AA alkaline batteries
.
FLUKE-3
53
AC
/
DC True-rms Clamp Meter, 2000 A,
amps on
ly
1
.
5
m s
ili
cone ru
bb
er test
l
ea
d
s, test pro
b
es, a
llig
ator
c
lips, so
f
t carr
y
in
g
case, six AA batteries, users manual
.
F
LUKE-
3
5
5
A
C
/
DC True-rms Clamp Meter, 2000 A
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/clamp
s
Clam
p
Meters
DMM vs. Clam
p
Mete
r
Wh
at you
k
now a
b
out
di
g
i
ta
l
mu
l
t
i
meters
a
n
d
c
l
amp
me
t
ers can
ma
k
e a
bi
g
d
ifference to
y
our
b
ottom
li
ne.
H
ow
we
ll
you
equ
i
p your
-
self to do
y
our wor
k
pl
ays a
big
ro
l
e
i
n your
s
u
ccess
.
Wh
en
i
t
c
omes to e
l
ectr
i
ca
l
test equ
i
pment, are
y
ou sure you have the right tools for
t
he job? Determine the answer to that
q
uest
i
on
b
y assess
i
ng your measur
-
i
ng needs, and learning a few things
ab
out
DMM
s an
d
c
l
amp meters—rea
d
t
he DMM vs.
C
lamp Meter application
note to
d
ay
.
Download this a
pp
lication note at
www.fluke.com
/
DMMvsClamp
Fluke
322
Fluke
321
LVD2
H3
Volt Light Clam
p
Meter Holster
S
e
e
pa
g
e5
6
S
ee
p
a
ge
6
2
TL223
TL223
TL71
S
ure
G
ri
p
Electrical
P
remium
T
e
s
t Le
a
d
S
et
T
e
s
t Le
a
d
S
e
t
S
ee pa
g
e5
3
S
ee
p
a
ge
54
7
F
luke 353/355 AC/DC True-rms
C
lamp Meters, 2000
A
F
or more in
f
ormation,
g
o to www.fluke.com/clamps
C
lam
p
Meters
V
ersatile, professional, accurat
e
Confidentl
y
take reliable readin
g
s with the true-rms Fluke
355 and 353 clamp meters—the tools of choice for hi
g
h cu
r
-
rent clamp-on amp meter measurement up to 2000 A
.
R
eliabl
y
handle a wide ran
g
e of hi
g
h-current applications
w
ith 2000 A ac + dc true-rms
,
1400 A ac
,
and 2000 A dc
L
ar
g
e 5
8
mm
(
2.3 in)
j
a
w
I
n-rus
h
current measurement
H
i
g
h volta
g
e measurement of 1000 V ac + dc true-rms,
6
00 V ac, and 1000 V dc
(
355 onl
y
)
R
esistance to 400 K
(
355 onl
y)
C
ontinuit
y
beeper
(
355 onl
y
)
F
requenc
y
measurement to
1
KH
z
S
electable low pass filter mod
e
M
in
/
Max
/
Av
g
L
ar
g
e
di
sp
l
a
y
w
i
t
h
b
ac
kligh
t
Ordering information on page 6.
True
RMS
Application note
Specifications – Clamp meters
C
lamp Meter ABCs
Wh
at
i
s a
cl
amp mete
r
a
n
d
w
h
at
c
an it do?
Wh
at mea
-
suremen
t
s
c
an
b
e ma
d
e
w
i
t
h
a c
l
amp
meter? Ho
w
d
o you get
th
e most ou
t
o
f a clamp
meter?
Whi
c
h
c
l
amp
meter
i
s
b
est su
i
te
d
to t
h
e env
i
ronment
t
he meter will be used in? The answers
t
o these questions can be found in this
a
pp
li
cat
i
on note.
D
own
l
oa
d
t
hi
s app
li
cat
i
on note at
www.fluke.com/Clam
p
ABCs
Residential/commercial
electrical General purpose Industrial electrical HVAC/R High end industrial,
utility
iFlex
accessory Leakage
321 322 365 373 374 375 376 381 902 353 355 i2500-10/
i2500-18 360
A
C current
A
C
volta
g
e
• •
Resistance
C
ontinuit
y
DC
volts
DC
current
T
rue-rm
s
F
requenc
y
A
C
+ D
C
volta
ge
A
C
+ D
C
c
urrent
Min
/
Max
/
Avg
T
emperature
C
a
p
acitance
S
pecial
f
eatures
I
nru
s
h
c
urrent m
o
d
e
Low
p
ass
lte
r
18
-inch iFlex Flexible
C
urrent Pr
o
be
O
ptional
O
ptiona
l
I
n
cl
u
d
e
d
I
n
cl
u
d
e
d
10
-inch iFlex Flexible
C
urrent Probe
Op
tiona
l
Op
tional O
p
tional O
p
tional
R
emote
di
sp
l
a
y
F
lashlight
/
torch
Displa
y
Display hold
B
acklight
S
peci
cations
J
aw opening 1 in
0
.7 in
1
.
3
in
1
.
3
i
n
1.
2
i
n
2
.
3
i
n
5
.7 in
/
3.2 in 1.
5
i
n
M
ax wire size 5
00
M
C
M
1
7 mm
(
0.67 in
)
7
50
MC
M
7
50
MCM or
t
hree 5
00
M
CM
12
5
0
M
C
M
C
urrent ran
g
e ac rms
0
to 4
00
.
0
A
0
to
200
.
0
A
0
to
600
.
0
A
0
to
999
.
9
A
0
to
600
.
0
A
0
to 14
00
A
0
to
2
5
00
A
0
to
60
A
Accurac
y
ac current
(
50/60 Hz
)
1.
8
% ±
5
counts 2 % ±
5
counts 1.
5
%
±
5
counts 3 %
±
5
counts
1
%
±
5
counts
AC Respons
e
A
vera
gi
n
g
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
T
rue-rm
s
A
vera
gi
n
g
C
urrent range dc
0
to 2
00
A
0
to
600
.
0
A
0
to 999.9
A
0
to 200 µA
0
to 2
000
A
A
ccuracy
d
c current 2
%
±
5
counts
2
% ± 5 counts 1 %
±
5
count
s
1
.
5
% ±
5
counts
V
o
l
tage range ac
0
to
600
.
0
V
0
to 1
000
V
600
.
0
V
0
to
600
.
0
V
A
ccuracy ac vo
l
tage 1.2 % ±
5
count
s
2 % ±
5
co
unt
s
1
%
±
5
co
unt
s
1.5
%
± 5 count
s
1 % ± 5
coun
t
s
1 % ± 5
coun
t
s
V
olta
g
e ran
g
e dc
0
to
600
.
0
V
0
to 1
000
V
0
to
600
.
0
V
0
to 1
000
V
Accurac
y
dc volta
g
e
1
% ± 5
co
un
ts
2
% ± 5
co
un
ts
1
%
±
5
count
s
1
%
±
5
co
unt
s
R
es
i
stance range
0
to 4
00
1
0
to
6000
1
0
to
60
k
1
0
to 9999
1
0
to 4
00
K
1
F
requency
m
easurement ran
g
e5
00
Hz 5 to 1
000
Hz
500
H
z
For more information, go to www.fluke.com/dmm
Digital Multimeters8
Pick the right digital multimeter for you
Digital multimeter selection guide
Models
Highest
accuracy
289
Industrial
troubleshooting
87V
Built-in
thermometer
179
Building
maintenance
117
HVAC/R
technicians
116
Remote
Display
233
Insulation
Multimeter
1587
IP 67
Industrial
28 II
Best for Data logging Variable speed
drives Every day use Wide variety of
electrical work HVAC
troubleshooting Perform two-man
jobs alone
Troubleshooting
and preventive
maintenance Harsh
environments
Basic features
True-rms readingsAC+DCACACACACACACAC
Basic dc accuracy 0.025 % 0.05 % 0.09 % 0.5 % 0.5 % 0.25 % 0.09 % 0.05 %
Wide bandwidth 100 kHz 20 kHz 20 kHz
Auto/manual ranging ••••••••
Digits 4-1⁄2 4-1⁄2 3-1⁄2 3-1⁄2 3-1⁄2 3-1⁄2 4-1⁄2
Counts 50000 20000 6000 6000 6000 6000 6000 20000
Measurements
Voltage ac/dc 1000 V 1000 V 1000 V 600 V 600 V 1000 V 1000 V 1000 V
Current ac/dc 10 A 10 A 10 A 10 A 600 µA 10 A 400 mA 10 A
Resistance 500 M150 M150 M140 M140 M140 M150 M150 M1
Frequency 1 MHz 200 kHz 100 kHz 50 kHz 50 kHz 50 kHz 100 kHz 200 kHz
Capacitance 100 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF 10 mF
Temperature +1350 °C +1090 °C +400 °C +400 °C +400 °C +500 °C +1090 °C
dB 60 dB
Conductance 50 nS 60 nS 60 nS
Duty cycle/pulse width ⁄– ⁄–
Motor drive measure-
ments/low pass filter •• ••
Continuity with beeper/
diode test ••••••••
Low ohms (50 1)
Display
Dual display
Analog bargraph ••••• •
Backlight ••••••••
Remote display
Data storage and exchange
Min/Max recording Time stamp •••••••
Fast Min/Max 250 µs 250 µs 250 µs
Display Hold/Auto (Touch)
Hold •••••• •
Relative reference ••
PC interface
Data logging
Readings memories 10,000
Other features
Automatic selection, LoZ ••
Insulation test range 0.01 M1 to 2 G1
Non-contact ac voltage
detector
Real-time clock
Overmolded case, inte-
grated holster •• •
Removable holster ••••
ToolPak compatibility •••••• •
Closed case calibration/
separate battery door ••••••••
Completely sealed/
watertight
Automatic power off ••••••••
Low battery indication ••••••••
Operating temperature
ranges –20 °C, +55 °C –20 °C, +55 °C –10 °C, +50 °C –10 °C, +50 °C 10 °C, +50 °C –10 °C, +50 °C –40 °C, +55 °C
IP rating IP 42 IP 30 IP 42 IP 42 IP 30 IP 67
Warranty and electrical safety
Warranty Limited lifetime Limited lifetime Limited lifetime Three-years Three-years Three-years Three-years Limited lifetime
Input alert ••
Dangerous voltage
indication ••••••••
CAT III measurements 1000 V 1000 V 1000 V 600 V 600 V 1000 V 1000 V 1000 V
CAT IV measurements 600 V 600 V 600 V 600 V 600 V 600 V
See page 11 12 13 14 15 9 17 10
9
Digi
ta
l
M
u
l
t
i
meter
s
Recommended accessories
Recommended kits
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
The new Fluke 233 wirele
ss
d
igital multimeter
What i
f
, as
a
n ele
c
tri
ca
l
p
ro
f
essional,
y
ou could
t
ake a clam
p-
o
n
a
mmeter
reading using
y
our digital
m
u
ltim
e
t
e
r
(
DMM
)
with
t
he di
scon
-
ne
c
t d
oo
r
o
r
MCC
c
ubi
c
le
doo
r
c
l
os
ed
?
D
own
l
oa
d
t
hi
s app
li
cat
i
on note at
www.fluke.com/233dmm
View this product demonstration
t
o learn more about the Fluke
233
.
w
ww.fluke.com
/
233video
Recommended accessories
Application note
Made in
the U.S.A.
of U.S. and
non U.S.
parts
Fl
u
k
e 233 Remote D
i
s
pl
a
y
D
igital Multimete
r
9
The Fluke
233
Remote Display Digital Multimeter allows
you to be in two places at once. The removable display
solves several problems. First, you no longer have to hold
b
o
th the meter
a
nd the te
s
t le
a
d
s
t
o
m
a
ke
a
me
as
ur
e
-
ment.
S
econd, making measurements in hard-to-reach
places is much easier, and third, it allows you to take
measurements in machines or panels that are physically
separated
f
rom a limit switch or an isolator switch. The
F
luke
233
is also designed to work in areas where the
operator can’t be close to the active measurement point,
l
ike
c
le
a
n r
oo
m
s
o
r h
a
z
a
rd
o
u
s
a
re
as.
Wireless technology allows the display to be carried
u
p to
30
feet away from the point of measurement for
a
dded
f
lexibility
The removable magnetic display can be conveniently
mounted where it is easily seen
Low-power
8
02.15.4 wireless technology does not
i
nter
f
ere with measurement accuracy
Use as a conventional multimeter when the display is
co
nne
c
ted
True-rms ac voltage and curren
t
Built-in therm
o
mete
r
Auto power off maximizes battery life
(
400 hours
)
Radio transmitter automatically turns o
ff
when the
d
isplay is connected to the meter
Record signal fluctuations using the Min/Max function
Functions Specifications
DC
volta
g
e
R
an
ge
0
.1 mV to 1
000
V
A
ccurac
y
0
.
2
5 % +
2
A
C voltage
R
ange
0
.1 mV to 1
000
V
A
ccuracy
1
.
0
% + 3
D
C
c
urren
t
R
ange
0
.1 mA to 1
0
A
Accuracy 1.
0
% + 3
AC
c
urren
t
R
ang
e
0
.1 mA to 1
0
A
A
ccuracy
1
.
5
% + 3
Resistance Range
0
.1 Ω to 4
0
MΩ
Ca
p
acitance
1
000 nF to 9999
µ
F
F
requenc
y
0
.1 Hz to
50
.
00
kHz
Tem
p
erature
-
40
°
C to +400
°
C (-40
°
F to 752
°
F)
P
ower Three AA batteries main bod
y
, two AA batteries displa
y
module
Batter
y
li
f
e4
00
hours
C
omplianc
e
C
AT IV
600
V
,
C
AT III 1
000
V
Size (HxWxL
)
5.3 cm x 5.3 cm x 19.3 cm (2.08 in x 2.08 in x 7.6 in)
W
e
igh
t 604
g
(1.3 Ib)
True
RMS
Specifications
Features
Features
Measure up to 1
000
V ac and d
c
Measure u
p
to 10 A
(
20 A for 30 seconds)
10,000 F capacitance range
F
requency to 50 kHz
R
es
i
stance, cont
i
nu
i
t
y
an
d
di
o
d
e tes
t
Min/Max and avera
g
e recordin
g
to capture variations automaticall
y
T
hree-year warrant
y
Ordering information
Included accessories Models
T
est
l
ea
d
s, temperature pro
b
e,
allig
ator c
li
ps,
b
atter
i
es, users
m
anual
.
FLUKE-2
33
R
emote
Di
sp
l
ay
M
u
l
t
i
meter
80
PK-
9
i4
00s
G
eneral Pur
p
ose Prob
e
A
C Current Clam
p
S
e
e
pa
g
e 5
8
S
e
e
p
a
g
e 6
0
80AK-
A
C35
Th
ermocou
pl
e
Ad
a
p
ter Soft Carrying Cas
e
S
e
e
pa
ge
59
S
e
e
pa
ge
54
TPA
K
TL220
Magnetic
S
ure
G
ri
p
Industrial
M
eter
H
anger
T
e
s
t Le
a
d
S
e
t
S
ee pa
g
e
62
S
e
e
p
a
ge
53
Product video
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/d
m
m
Digi
ta
l
M
u
l
t
i
meter
s
10
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Application note
T
ou
gh
p
l
aces, tou
gh
too
l
s
O
ut on the
j
ob site,
co
n
c
rete
f
ini
s
her
s
stand ready
t
o sha
p
e wet
ready-mi
x
i
nt
o
a
new
s
tret
c
h
of
h
ighway.
M
ixer tru
c
k
s
a
re lined u
p
a
t the
co
n
-
c
rete b
a
t
c
h
p
lant, waitin
g
to
t
a
ke
o
n their l
oa
d
s
. But h
o
ld
o
n—
a
n
electrical
p
roblem has shut down the
p
lant. It’s time to call Keithly Electric.
Download this a
pp
lication note at
www.fluke.com
/
toughdmms
Product video
Recommended accessories
PV
350
i41
0
P
ressure-
V
acuum
M
o
d
u
le
A
C
/
DC Current Clamp
See
page
63
See
page
60
CXT80 C550
E
xtreme H
a
rd
Cas
e
T
oo
l
B
ag
S
e
e
p
a
g
e
54
S
e
e
p
a
g
e
54
TPAK
TLK
-
225
M
a
g
net
i
c
S
ure
G
rip Maste
r
M
eter Han
g
er Accessor
y
Set
See
page
6
2
S
e
e
page
55
Made in
the U.S.A.
of U.S. and
non U.S.
parts
F
luke 27 II/28 II Industrial
D
igital Multimeters
T
he 27 II and 2
8
II Digital Multimeters are designed
f
or tough work environments. Both meters have
IP
6
7 waterproof and dustproof rating. They both
h
ave an extended operating temperature range
o
f -15
°
C to + 55
°
C
(
5
°
F to 131
°
F
)
and 95 %
h
umidity
.
Unique
f
unction
f
or accurate voltage and
f
requency measurements on adjustable speed
m
otor drives and other electrically noisy equip
-
m
ent
(
2
8
II
)
B
uilt-in thermometer conveniently allows you
to take temperature readings without having to
c
arry a separate instrument
(
2
8
II)
Hi-resolution 20,000 count display mode
(
2
8
II)
R
esistance and continuity. Relative mode to
rem
o
ve te
s
t le
a
d re
s
i
s
t
a
n
c
e
f
r
o
m l
o
w
o
hm
s
m
e
as
uremen
ts
L
arge digit display with bright, two-level
b
acklight
B
acklit keypad buttons allow
f
or easy visibility
i
n l
o
w-lit
a
re
as
O
ptional magnetic hanger for easy setup and
viewing
f
reeing your hands
f
or other task
s
U.
S
. Mine
S
afety and Health Administration
(
MSHA) approve
d
Specification 27 II 28 II
DC voltage
R
ang
e
0
.1 mV to 1
000
V
A
ccuracy
0
.
05
% +
1
0
.
05
% +
1
AC voltag
e
R
ang
e
0
.1 mV to 1
000
V
Accuracy
0
.
5
% +
3
0
.7 % +4
DC
c
urrent Range
0
.1
µ
A to 10
A
A
ccuracy
0
.2 % +
4
0
.2 % + 4
AC current Range 0.1
µ
A to 10 A
Accurac
y
1.
5
% + 2
1
.
0
% + 2
R
esistanc
e
R
an
ge
0
.1
to
50
M
D
ispla
y
counts
6000
6
000 / 19
,
999
C
apacitance 1 nF to
9999
µ
F
Frequenc
y
0
.5 Hz to 1
99
.
99
kH
z
T
emperatur
e
-200
°
C to +1090
°
C
L
ow pass filter (measurement on VSD’s)
Y
e
s
C
omplianc
e
C
AT IV
600
V
,
C
AT III 1
000
V
M
e
as
urement met
hod
A
v
g
. respon
di
n
g
T
rue-rm
s
Po
we
r
Th
ree
AA
ba
tter
i
e
s
Battery lif
e
800
hours
D
imensions
(
DxWxH
)
2
.
5
in x 3.93 in x 7.
8
in
W
e
i
g
h
t w
i
t
h
h
o
l
ster
6
9
8
.5 g
(
1.54 lb)
True
RMS
Specifications
Features
Features
T
ested to withstand a 3 m (10 ft) dro
p
W
ide 1000 V measurement rang
e
T
rue-rms ac voltage and current for accurate measurements on non-linear signals
(
2
8
II)
Avera
g
e respondin
g
volta
g
e and current measurements (27 II
)
10 A continuous (20 A for 30 seconds
)
F
requenc
y
and capacitanc
e
Record signal fluctuations using the Min/Max functio
n
Ordering information
Included accessories Models
T
est
l
ea
d
s, temperature pro
b
e,
allig
ator c
li
ps,
b
atter
i
es,
h
o
l
ster,
u
sers manual.
FL
U
KE-27-I
I
I
n
d
u
s
tr
ial
M
u
l
t
i
mete
r
FLUKE-2
8
-I
I
I
n
d
u
s
tr
ial
M
u
l
t
i
mete
r
MSHA
United States Department of Labor
Mine Safety and Health Administration
How dirty does your DMM get
?
W
a
t
c
h the vide
o
bel
o
w t
o
s
ee m
o
re.
w
ww.fluke.com
/
dirt
y
dmm
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/d
m
m
11
Digi
ta
l
M
u
l
t
i
meters
Recommended accessories
Recommended kits
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Specifications
Features
Ordering information
Included accessories Models
T
est leads, alligator clips,
holster, 9 V batter
y
(installed),
users manual on
C
D,
g
ettin
g
s
tarted guide
.
FLUKE-2
89
True-rms Industrial Logging Multimeter with TrendCapture
FLUKE-2
87
True-rms Electronics Logging Multimeter with TrendCaptur
e
FLUKE-289
/
FV
F
True-rms Industrial Logging Multimeter Combo Kit with TrendCapture
FLUKE-287
/
FVF True-rms Electronics Lo
gg
in
g
Multimeter
C
ombo Kit with Trend
C
apture
Fl
u
k
e 289 an
d
287 True-rms
L
ogging Multimeter
s
Functions Range and resolution Basic Accuracy
AC
v
o
lt
s
o
r d
c
v
o
lt
s
50.000 mV, 500.00 mV, 5.0000 V, 50.000 V,
5
00
.
00
V, 1
000
.
0
V
0
.
0
2
5
%
0
.4 %
(
true-rms
)
(
AC
)
AC
c
urrent d
c
c
urrent 5
00
.
00
µA, 5
000
.
0
µA, 5
0
.
000
mA, 4
00
.
00
mA,
5.
0000
A
,
1
0
.
000
A
0
.15 %
0
.7 % (true-rms
)
Temperature (excludin
g
probe
)
-
200.0
°
C to 1350.0
°
C (-328.0
°
F to 2462.0
°
F
)
1.
0
%
R
es
i
stanc
e
5
0
.
000
1
,
5
00
.
00
1
,
5.
0000
k
1
,
5
0
.
000
k
1
,
5
00
.
00
k
1
,
5.
0000
M
1
,
5
0
.
00
M
1
,
5
00
.
0
M
1
0
.
0
5 %
C
a
p
acitance 1.
000
nF,1
0
.
00
nF, 1
00
.
0
nF, 1.
000
µ
F, 1
0
.
00
µ
F, 1
00
.
0
µ
F, 1
000
µ
F,
10.00 mF, 100 mF
1
.
0
%
Frequency
9
9.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz .
005
%
Made in
the U.S.A.
of U.S. and
non U.S.
parts
True
RMS
Features
Multiple on screen display
s
Ye
s
T
rue-rm
s
ac
ba
n
d
w
id
t
h
100
kH
z
dBV
/
dBm
Y
e
s
D
C
mV resolutio
n
1
µ
V
Megohm rang
e
u
p
to 5
00
M
1
Co
ndu
c
t
a
n
ce
50
.
00
nS
Continuity beepe
r
Y
e
s
E
lapse time clock
/
time of da
y
clock
Y
e
s
M
in/Max/Av
g
/dut
y
c
y
cle/pulse width
Y
e
s
I
solated o
p
tical DMM interface with USB PC connection
Y
e
s
A
uto
/
touch hol
d
Y
e
s
Over
200
hours lo
gg
in
g
capacit
y
with new power savin
g
function
Y
e
s
Warrant
y
Limit
ed
li
fe
tim
e
Find little problems before they become bi
g
ones.
The Fluke 2
8
9 and 2
8
7 are the next generation in high
per
f
ormance industrial logging multimeters
.
Large 5
0
,
000
count,
1
/
4 VGA dot matrix
d
isplay with white
backligh
t
Logging
f
unction
with expanded memo
r
f
or unattended monito
o
f
signals over time. Usin
g
on-board Trend
C
apture,
u
sers can graphically review logged readings with
-
out needing a P
C
. Store up to 1
0
,
000
recorded events
S
ave, name, and recall multiple logging sessions
b
efore P
C
download is necessar
y
Z
oom on trend, provides unprecedented ability to
view and analyze Trend
C
apture data; zoom in up to
14 time
s
Two terminal 5
0
ohm range with 1 milliohm resolu
-
t
ion, 1
0
mA source current. Useful for measuring and
c
omparing di
ff
erences in motor winding resistance or
c
ontact resistance
(
2
8
9
)
Low pass
f
ilter
f
or accurate voltage and
f
requency
measurements on adjustable speed motor drives and
other electrically noisy equipment
(
2
8
9)
LoZ volts. Low impedance voltage
f
unction
f
or
eliminating ghost voltages. Also recommended when
t
esting for absence or presence of live power
(
2
8
9
)
Trend
C
apture displays V dc logged data.
TLK
289
TLK
287
I
ndustrial
E
lectroni
c
T
e
s
t Le
a
d
S
e
t
Te
s
t Le
a
d
S
et
S
e
e
p
a
ge
55
S
e
e
p
a
ge
55
TPA
K
i41
0
M
agnetic Meter Hange
r
A
C/DC Current Clam
p
S
e
e
pa
g
e 6
2
S
e
e
p
a
ge
6
1
FVF-S
C2
C280
F
lukeView Forms
S
oft Cas
e
S
e
e
p
a
ge
63
S
e
e
p
a
ge
54
287
/
FVF kit includes:
True-rms electronic logging multimeter with
TrendCa
p
ture
FlukeView F
o
rm
s
So
ftw
a
re
a
nd
ca
ble
T
em
p
erature
p
ro
be
M
odular test leads
(
red, black
)
M
odular test probes (red, black)
A
lli
g
ator clips (red, black)
So
ft
cas
e
289
/
FVF kit includes
:
True-rms industrial logging multimeter with
TrendCa
p
ture
FlukeView F
o
rm
s
So
ftw
a
re
a
nd
ca
ble
Tem
p
erature
p
rob
e
S
ili
co
ne te
s
t le
a
d
s
et
Alli
gator c
li
p
s
M
eter
h
ang
i
ng accessory
So
ft
cas
e
For more information, go to www.fluke.com/dmm
Digital Multimeters12
Specialty models
Recommended kits
Check price and availability at
www.fluke.com/wtb
Recommended accessories
12
PV350 i400
Pressure-Vacuum Module AC Current Clamp
See page 63 See page 60
Specifications
Features
Fluke 87V Ex
Intrinsically Safe
True-rms Multimeter
See page 39 for more
information.
Fluke 87V Industrial Multimeter
For industrial productivity
Functions Range and resolution
Basic accuracy
87V 83V
DC volts 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.05 % 0.1 %
AC volts 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.7 % (true-rms) 0.5 %
DC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A 0.2 % 0.4 %
AC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A, 10.00 A 1.0 % (true-rms) 1.2 %
Temperature (excl. probe) -200 °C to 1090 °C (-328 °F to 1994 °F) 1.0 %
80BK Temperature Probe -40 °C to 260 °C (-40 °F to 500 °F) 2.2 °C or 2 %
Resistance 600.0 1, 6.000 k1, 60.00 k1, 600.0 k1, 6.000 M1, 50.00 M10.2 % 0.4 %
Capacitance 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 9,999 µF 1.0 % 1.0 %
Frequency 199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz 0.005 % 0.005 %
The Fluke 87V has measurement functions, trouble-
shooting features, resolution and accuracy to solve
more problems on motor drives, in-plant automation,
power distribution and electro-mechanical equipment.
Unique function for accurate voltage and frequency
measurements on adjustable speed motor drives and
electrically noisy equipment (87V and 87V Ex)
Large digit display with bright two level backlight
makes the 87V significantly easier to read
Measure 20 A for up to 30 sec, 10 A continuously
Optional magnetic hanger for easy setup and view-
ing while freeing your hands for other tasks (TPAK)
Expanded capacitance range to 10,000 µF
Electrical safety
All inputs are protected to CAT III 1000 V and CAT IV
600 V. They can withstand impulses in excess of
8,000 V to help protect you from arc blast resulting
from surges and spikes.
Available in intrinsically safe version as the
Fluke 87V Ex.
Also available as 83V average responding
multimeter, see below for specifications.
Battery life: 400 hours typical with backlight off. Size (LxWxD): 201 mm x 98 mm x 52 mm (7.9 in x 3.8 in x 2 in).
Weight: 355 g (22 oz).
Features 87V Ex 87V 83V
Peak capture to record transients as fast as 250 µs ••
Measure up to 1000 V ac and dc •••
Auto and manual ranging for maximum flexibility •••
Analog bargraph •••
Frequency to 200 kHz and % duty cycle •••
Min/Max and average recording to capture variations automatically •••
Relative mode to remove test lead resistance from low ohms measurements •••
Access door for fast battery changes without breaking the calibration seal •••
Limited lifetime warranty One-year ••
Ordering information
Fluke 87V/E2 Industrial Electrician’s Combo Kit
Industrial multimeter
Lightweight soft case to provide optimal protection
and storage
1.5 m silicone leads resist heat
Removable probes with 4 mm of exposed metal for
use on industrial circuits
Retractable long reach alligator clips
Meter hanging accessory
Type K temperature probe
L210 CXT80
Probe Extender with Light Extreme Case
See page 62 See page 54
Made in
the U.S.A.
of U.S. and
non U.S.
parts
True
RMS
Included accessories Models
Test leads, alligator clips, holster, 9 V battery
(installed), temperature probe (87V only), users
manual on CD, operator’s guide.
FLUKE-87-5 Industrial True-rms Multimeter with Temperature
FLUKE-83-5 Industrial Multimeter
FLUKE-87V Ex Intrinsically Safe True-rms Multimeter
FLUKE-87-5/E2 Industrial Electrician’s Combo Kit
TPAK TL220
Magnetic SureGrip Industrial
Meter Hanger Test Lead Set
See page 62 See page 55
For more information, go to www.fluke.com/dmm 13Digital Multimeters
Check price and availability at
www.fluke.com/wtb
Check price and availability at
www.fluke.com/wtb
Fluke 170 Series Digital Multimeters
For maintenance and eld service
Specifications
Ordering information
Features
The Fluke 179 True-rms Multimeter has the features
needed to find most electrical and HVAC problems.
Simple to use with significant improvements over the
original Fluke 70 Series.
Wide 1000 V measurement range
True-rms for precise measurement of non-linear
signals
Capacitance, resistance, continuity and frequency
Built-in thermometer (Fluke 179 only)
Large, easy-to-read display
Backlight for work in dimly lit areas
(Fluke 177 and179 only)
Min/Max/Avg to record signal fluctuations
Display hold and auto hold
Manual and automatic ranging
Electrical safety
All inputs are protected to measurement CAT III 1000 V
and CAT IV 600 V. This meter can withstand transient
impulses in excess of 8000 V to help protect you from
arc blasts resulting from surges and spikes.
Features 179 177 175
Max voltage 1000 1000 1000
True-rms •••
Temperature
Basic dc accuracy 0.09 % 0.09 % 0.15 %
Backlight ••
Min/Max/Avg •••
ToolPak meter hanging kit with magnet Opt Opt Opt
Limited lifetime warranty •••
All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range.
10 A continuous, 20 A for up to 30 seconds.
Voltage frequency is specified from 2 Hz to 100 kHz. Current frequency is specified from 2 Hz to 30 kHz.
Battery life: 200 hours typical for alkaline.
Size (HxWxL): 4.3 cm x 9.0 cm x 18.5 cm (1.7 in x 3.5 in x 7.3 in).
Functions Range and resolution Best accuracy
DC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 0.09 % (Models 177 and 179)
± 0.15 % (Model 175)
AC voltage1600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 1.0 % of reading
DC current 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2± 1.0 % of reading
AC current2 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2± 1.5 % of reading
Resistance 600.0 1, 6.000 k1, 60.00 k1, 600.0 k1, 6.000 M1, 50.00 M1± 0.9 % of reading
Capacitance 1000 nF, 10.00 µF, 100.0 µF, 9999 µF ± 1.2 % of reading
Frequency399.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz ± 0.1 % of reading
Temperature (Model 179) -40 ºC to +400 ºC (-40 ºF to +752 ºF) 1.0 % of reading
FOM i2000 Flex
Fiber Optic Meter AC Current Clamp
See page 63 See page 60
LVD2 C35
Volt Light Soft Carrying Case
See page 62 See page 54
Made in
the U.S.A.
of U.S. and
non U.S.
parts
True
RMS
Recommended accessories
Recommended kits
179/1AC-II Electrician’s Multimeter and
Voltage Tester Combo Kit
True-rms digital multimeter
Non-contact voltage detector
Soft case
Alligator clips
SureGrip test probes
Silicone test leads, 1.5 m
Type K temperature probe
Meter hanging accessory
179/EDA2 Electronics Multimeter and
Deluxe Accessory Combo Kit
True-rms digital multimeter
Soft case
Electronic test probes
SureGrip silicone test leads
SureGrip heavy duty hook clips
Type K temperature probe
Meter hanging accessory
Included accessories Models
Test leads, 9 V battery (installed) and
manual. The Fluke 179 comes with
an additional temperature probe.
FLUKE-179 Digital Multimeter
FLUKE-175 Digital Multimeter
FLUKE-177 Digital Multimeter
FLUKE-179/1AC-II Electricians Combo Kit
FLUKE-179/EDA2 Electronics Combo Kit
TPAK TL238
Magnetic Test Lead Set for High
Meter Hanger Energy Environments
See page 62 See page 57
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/d
m
m
Digi
ta
l
M
u
l
t
i
meter
s
14
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Fea tu re s 117 115 113
V
o
l
t
Al
ert
A
utoVolt
/
Lo
Z
LoZ
A
na
l
og
b
argrap
h
L
arge
b
ac
kli
t
di
g
i
ta
l
di
sp
l
ay
T
rue-rm
s
f
o
r
acc
ur
a
te me
as
urement
s
o
n n
o
n-line
a
r l
oa
d
s
M
in/Max recording
D
isplay hold
3-1⁄2 digit
s
6000
count
s
C
AT III
600
V safet
y
rate
d
T
hree-
y
ear warrant
y
1
17
/
322 Electrician’s Combo Kit
True-rms di
g
ital multimeter with
n
on-contact volta
g
e detectio
n
Com
p
act clam
p
meter
Test lead se
t
M
agnetic meter hanging strap
D
eluxe carrying case with shoulder stra
p
TPAK
TL220
Ma
g
netic SureGri
p
Industrial
M
eter Hange
r
T
e
s
t Le
a
d
S
et
S
e
e
p
a
ge
62
S
e
e
p
a
ge
55
LVD
2
C
35
Volt Light
S
oft Carrying Case
S
e
e
pa
ge
62
S
e
e
p
a
ge
54
Recommended accessories
Recommended kits
Specialty model
Fl
u
k
e 117 an
d
115
True-rms D
i
g
i
ta
l
Mu
l
t
i
meter
s
T
he 117 Digital Multimeter includes integrated non
-
c
ontact voltage detection to help get the job done
f
aster
.
T
he Fluke 115 Digital Multimeter is the solution
f
or a wide variety o
f
electrical and electronic testing
applications
.
V
o
ltAler
t
technology
f
or integrated non-contact
voltage detection
(
117)
A
utoVolt feature for automatic ac/dc voltage selection
(
117
)
LoZ: Low input impedance prevents
f
alse readings
d
ue to “ghost voltage”
(
117)
Large display and white LED backlight to work in
poorly lit areas more e
ff
ectively
C
ompact ergonomic design for one-handed operation
M
in/Max/Avg to record signal fluctuation
s
Compatible with optional magnetic hanger
(
TPAK) for
h
ands
f
ree operatio
n
Current measurement 20 A
(
30 sec
-
onds momentary; 1
0
A continuous
)
Resistance, continuity,
f
requency
a
nd capacitanc
e
Functions 117 115 113 Accuracy
V
olts ac
/
dc
600
V
600
V
600
V
0
.5 % +
2
C
urrent ac
/
d
c
1
0
A
1
0
A
1.
0
% +
3
Re
s
i
s
t
a
n
ce
40
M
1
40
M
1
60
k
1
0
.9 % + 2
C
apacitance
1
nF to 9,999 µ
F
1
nF to 9,999 µ
F
1
.
9
% +
2
Diod
e te
st
Y
e
s
Y
e
s
Y
e
s
Frequenc
y
5
Hz to 5
0
kH
z
5
Hz to 5
0
kH
z
0
.1 % +
2
Fluke 113
B
as
i
c e
l
ectr
i
ca
l
an
d
u
t
ili
ty mu
l
t
i
mete
r
V
C
HEK
L
o
Z
l
o
w
i
mpe
d
ance measur
e
-
ment function to
simultaneously test for
vo
l
tage or cont
i
nu
i
t
y
True-rms for accurate
a
c measuremen
t
s on
non-
li
near
l
oa
ds
Record signal fluctuations using the
M
in
/
Max function
Di
o
d
e an
d
capac
i
tance measurement
s
I
ntegra
l
h
o
l
ster w
i
t
h
pro
b
e
h
o
ld
ers
f
or easy storag
e
Auto and manual ranging for added
u
ser functionality
M
eets
C
AT III
600
V and
C
AT IV
300
V
standards for a higher level of safety
True
RMS
Fluke
117
Fluke
115
Specifications
Features
Ordering information
Included accessories Models
T
est
l
ea
d
s,
h
o
l
ster, users
manual and
9
V batter
y
(
installed).
FLUKE
-
117
M
ultimeter with Non-
C
ontact Volta
g
e
FLUKE
-
115
M
u
l
t
i
mete
r
FLUKE-11
3
U
t
ili
ty
M
ete
r
FLUKE-117
/
322
E
le
c
tri
c
i
a
n’
s
Co
mb
o
Kit
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/d
m
m
15
Digi
ta
l
M
u
l
t
i
meters
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Recommended kits
80
AK-
A
80
PK-
24
DMM Adapter SureGrip Ai
r
See
page
59
T
em
p
erature Probe
S
e
e
p
a
ge
58
80
PK-1
8
80
BK-
A
Pipe
C
lam
p
Inte
g
rate
d
T
em
p
erature Probe Ki
t
T
em
p
erature Prob
e
S
e
e
pa
ge
5
8
S
ee pa
ge
5
8
Fl
u
k
e 116 an
d
114 D
i
g
i
ta
l
Mu
l
t
i
meters
HVAC/R and electrical troubleshooting
Features 116 114
T
em
p
erature
Microam
p
s
F
requenc
y
C
a
p
acitance
Diode test
AutoVolt
/
Lo
Z
Analo
g
bar
g
raph
Lar
g
e backlit di
g
ital displa
y
T
rue-rms
f
or accurate measurements on non-linear loads
Min
/
Max recordin
g
Di
sp
l
a
y
h
o
ld
3
-1
2
di
g
it
s
6000
counts
C
AT III
600
V safet
y
rate
d
Th
ree-year warrant
y
1
16
/
62 HVAC Combo Ki
t
H
VA
C
multimeter with tem
p
erature and microam
ps
I
n
f
rared thermomete
r
Test lead se
t
Pi
p
e wra
p
thermocou
p
le
Thermocou
p
le ada
p
ter
Type K integrated temperature probe
M
agnet
i
c meter
h
ang
i
ng strap
D
e
l
uxe carry
i
ng case w
i
t
h
s
h
ou
ld
er stra
p
1
16
/
322 HVAC Combo Ki
t
H
VAC multimeter with tem
p
erature and microam
ps
Com
p
act clam
p
meter
Test lead se
t
Pi
p
e wra
p
thermocou
p
le
Thermocou
p
le ada
p
ter
Th
ermocou
pl
e
b
ea
d
p
ro
be
M
eter
h
ang
i
ng accessory
D
e
l
uxe carry
i
ng case w
i
t
h
s
h
ou
ld
er stra
p
True
RMS
F
luke 11
6
Fluke
114
Features
T
he Fluke 11
6
Digital Multimeter was specifically
d
esigned for the HVA
C
professional.
T
he Fluke 114 Digital Multimeter is the best troubl
e
-
s
hooting tool for “go/no-go” testing
.
B
uilt in thermometer for HVAC applications
(
116)
M
icroamps to test flame sensors
(
116)
A
utoVolt: Automatic ac/dc voltage selection (114)
L
oZ: Helps prevent
f
alse readings due to ghost voltage
M
in/Max/Avg to record signal fluctuations
R
esistance, continuity,
f
requency and capacitanc
e
L
arge white LED backlight to work in poorly lit area
s
C
ompact ergonomic design for one-handed operation
C
ompatible with optional magnetic hanger
(
TPAK)
Functions Range and resolution Best accuracy
V
olts ac
/
dc
600
V
0
.
5
% + 2
Current ac
/
dc (116 onl
y)
600
.
0
µ
A
1
.
0
% +
2
T
emperature (116 onl
y)
+
400
°
C
1
.0 % + 18
R
esistance
40
M
1
0
.
9
% +
2
Capacitance
(
116 on ly)
1
nF to 9,999
µF
1.9 % + 2
Frequency (116 only
)
5
Hz to
50
kH
z
0
.1 % + 2
Specifications
Ordering information
Included accessories Models
T
est leads, inte
g
rated temperature probe (116 onl
y
),
holster, users manual and 9 V battery
(
installed).
FLUKE-11
6
HVA
C
Multimeter with Temperature and Microamp
s
FLUKE-11
4
El
ectr
i
ca
l
M
u
l
t
i
meter
FLUKE-116
/
62 HVA
C
C
ombo Kit
FLUKE-116
/
322 HVA
C
Co
mb
o
Kit
Fluke 116
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/d
m
m
Digi
ta
l
M
u
l
t
i
meter
s
16
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Specifications (77 IV)
Ordering information
Included accessories Models
T
est leads, carrying case
(88
V only), users
manual and 9 V batter
y
(installed).
FLUKE-
88
-
5
A
ut
o
m
o
tive Multimeter
FL
U
KE-77-
4
Digital Multimeter
FLUKE-88-5
/
A KIT
A
utomotive Multimeter Combo Kit
Recommended accessories
Recommended kits
Fl
u
k
e 88V an
d
77 IV D
i
g
i
ta
l
Mu
l
t
i
meters
For automotive, eld service or bench repair
Functions Range Best accuracy Best resolution
V d
c
600
.
0
mV to 1
000
(
0.3 % + 1
)
0
.1 m
V
V
ac
6
.
000
V to 1
000
V
±
(
2.0 % + 2
)
1
.
0
mV
A
d
c
60
.
00
mA to 1
0
A ± (1.5 % + 2)
0
.
0
1m
A
A
a
c
60
.
00
mA to 1
0
(
2.5 % + 2)
0
.
0
1 mA
R
e
sis
t
a
n
ce
600
.
0
Ω to
50
MΩ ±
(
0.5 % + 1
)
0
.1
C
apacitanc
e
1
nF to
9
,
999
µ
F
± (1.2 % + 2)
1
n
F
F
requency
9
9.99 Hz to 99.99 kHz ±
(
0.1 % + 1)
0
.
0
1 H
z
Made in
the U.S.A.
of U.S. and
non U.S.
parts
u
ke 88V Automotive Multimete
r
e
Fluke
88
V Automotive Multimeter is designed to
p automotive professionals solve problems faster.
i
s DMM has the measurement functions
,
troubleshoot
-
g
features and accuracy to solve virtually any problem
th
convent
i
ona
l
an
d
h
y
b
r
id
ve
hi
c
l
es.
A
utomotive test functions include dc and ac voltage,
r
es
i
stance an
d
curren
t
M
in
/
Max recording for logging the highest and lowest
r
ea
di
ngs over t
i
me
F
requency measurements for magnetic sensors and
a
c
/
dc frequency signals
D
uty cycle for variable duty cycle signals with selec
t
-
abl
e tr
i
gger, s
l
ope an
d
l
eve
l
P
ulse width for fuel injector on-time measurement
s
C
onductance testing for secondary ignition coils
R
PM measurements for DIS and conventional ignition
s
ys
t
em
s
B
u
il
t-
i
n t
h
ermomete
r
Fluke 77 IV Digital Multimeter
T
he 77 IV Di
g
ital Multimeter has the features needed
to repa
i
r most e
l
ectr
i
ca
l
an
d
e
l
ectron
i
c pro
bl
ems.
Thi
s
m
eter is simple to use and has si
g
nificant improvements
o
ver Fluke’s ori
g
inal 70 Series with more measuremen
t
functions, conformance to the latest safet
y
standards,
an
d
a muc
h
l
ar
g
er
di
sp
l
a
y
t
h
at
s eas
i
er to v
i
ew
.
Wide 1000 V measurement ran
g
e
A
vera
g
e respon
di
n
g
ac measurements
0
.3 % accurac
y
1
0 amps continuou
s
F
requenc
y
an
d
capac
i
tanc
e
R
es
i
stance an
d
cont
i
nu
i
t
y
L
ar
g
e
di
sp
l
a
y
B
ackli
g
ht for work in dim areas
M
in
/
Max to record si
g
nal fluctuation
s
I
nte
g
ra
l
h
o
l
ster w
i
t
h
pro
b
e
h
o
ld
ers
F
ree
y
our
h
an
d
s w
i
t
h
t
h
e opt
i
ona
l
TPAK
ma
g
net
i
c
h
an
g
e
r
A
uto an
d
manua
l
ran
gi
n
g
A
utomotive multimeter
H
eat resistant silicone test leads
Removable shar
p
p
oint test
p
robe
s
Large jaw alligator clips
Tem
p
erature
p
rob
e
I
nductive
p
ick-u
p
A
utomot
i
ve
b
ac
kp
ro
b
e
pi
n
s
I
nsu
l
at
i
on p
i
erc
i
ng pro
b
e
M
eter
h
ang
i
ng accessory
D
ura
bl
e carry
i
ng case
TP4
0
TP88
A
ut
o
m
o
t
i
ve
Back
Rigid
B
ac
k
P
ro
b
e
P
robe Pin Se
t
Pin Set
Se
e
page
56
Se
e
page
56
TPAK
i400
M
a
g
net
i
c
M
eter
H
an
g
e
r
AC
C
urrent
C
lam
p
S
e
e
page
62
S
e
e
page
60
TLK
281
TLK
282
Automotiv
e
Deluxe Automotive
T
e
s
t
L
e
ad
Ki
t
T
e
s
t
L
e
ad
Ki
t
S
e
e
p
a
g
e5
6
S
e
e
p
a
ge
56
TL
225
TLK
-
225
S
ureGrip Stra
y
Volta
ge
S
ureGrip Master
Ada
p
ter Test Lead Kit
A
ccessory Ki
t
S
e
e
p
a
ge
55
Fluke 88V
Fl
u
ke 77 IV
Made in
the U.S.A.
of U.S. and
non U.S.
parts
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/d
m
m
17
Digi
ta
l
M
u
l
t
i
meters
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Recommended kits
Specifications
Ordering information
Included accessories Models
Remote
p
robe, test leads,
a
llig
ator c
li
ps,
Ty
pe
K
t
hermocouple (1587 onl
y
), hard
case and users manual
.
FLUKE-1
5
7
7
In
s
ul
a
ti
o
n Multimete
r
FLUKE-1
587
In
s
ul
a
ti
o
n Multimete
r
FLUKE-1587
/
E
T
Advanced Electrical Troubleshooting Ki
t
FLUKE-1587
/
MD
T
Advanced Motor and Drive Troubleshooting Kit
Two
p
ower
f
ul tools in on
e
T
he Fluke 15
8
7 and 1577 Insulation Multimeters combine
a digital 1 kV insulation tester with a full-featured, true-
rms
di
g
i
ta
l
mu
l
t
i
meter
i
n a s
i
ng
l
e compact,
h
an
dh
e
ld
un
i
t,
w
hich provides maximum versatility for both troubleshoot
-
i
ng an
d
prevent
i
ve ma
i
ntenance
.
Insulation test
(
15
8
7: 0.01 M to 2 G)
(
1577: 0.1 M to
600
M
)
Insulation test voltages
(
15
8
7: 50 V, 100 V, 250 V, 500 V,
1
000 V),
(
1577: 500 V, 1000 V) for many applications
L
ive circuit detection prevents insulation test if voltage
>
30
V is detected for added user protectio
n
A
uto-discharge of capacitive voltage for added user
p
rotect
i
o
n
F
ilter for motor drive measurements
(
15
8
7 only
)
A
C
/
DC voltage, dc millivolts, ac
/
dc milliamps, resistance
(
W), and continuity
C
apacitance, diode test, temperature,
M
in
/
Max, and frequency (Hz) (1587 only
)
A
uto power off to save battery power
L
arge
di
sp
l
ay w
i
t
h
b
ac
kli
g
h
t an
d
l
arge
di
g
i
ts
I
nc
l
u
d
e
d
accessor
i
es:
R
emote pro
b
e, test
l
eads and probes, alligator clips,
(
Type K
thermocouple, 15
8
7 only)
A
ccepts opt
i
ona
l
Fl
u
k
e
TPAK
magnet
i
c
h
anging system to free your hands for
o
t
h
er wor
k
R
ugge
d
, ut
ili
ty
h
ar
d
case a
ll
ows you to
b
ring everything you need for the jo
b
Features 1587 1577 1507 1503
Insulation test voltages 50 V, 100 V,
2
5
0
V
,
5
00
V
,
1
000
V
Insulation test voltages 500 V, 1000 V
I
nsulation resistanc
e
0
.
0
1
M
1
to
2
.
0
G
1
0
.1
M
1 to
600
M
1
0
.
0
1 M
1
to 1
0
G
1
0
.1
M
1
to
2
G
1
Auto-dischar
g
e o
f
capacitive volta
ge
I
nsulation test smoothin
g
readin
g
Frequenc
y
C
apacitanc
e
Di
o
d
e test
T
emperatur
e
M
in
/
Max
Low-pass filter (for work on VSDs)
A
C
/
DC Voltag
e
DC
milliv
o
lt
s
A
C
/
DC milliam
p
s
R
e
sis
t
a
n
ce
0
.1
1
to
50
M
1
0
.1
1
to
50
M
1
0
.1
1
to 2
0
.
00
K
1
0
.1
1
to 2
0
.
00
K
1
Continuit
y
Warrant
y
T
hree-yea
r
T
hree-year
O
ne-year
O
ne-yea
r
Remote probe, test leads, alligator clips
Type K thermocouple
R
ugged, utility hard case
A
uto
p
ower o
ff
P
a
g
e number
17
17
24
24
Fl
u
k
e 1587 an
d
1577
I
nsulation Multimeters
G
et more value and productivit
y
E
stablishing a preventive maintenance program is
becoming critical to maintaining the uptime of electrical
e
quipment and can si
g
nificantl
y
reduce both planned
and un
p
lanned downtime. Un
p
lanned downtime costs
are di
ff
icult to calculate, but are o
f
ten signi
f
icant. For
s
ome industries, it can represent 1 % to 3 % of revenue
(potentiall
y
30 % to 40 % of profits) annuall
y.
T
hese kits can help you be proactive and e
ff
icient with
your maintenance and can save you up to 10 % off the
i
ndividual price of the tools.
True
RMS
Fluke
1587
Fluke
1577
C2
5TL
27
Meter Cas
e
Heavy Dut
y
S
e
e
pa
g
e
54
T
e
s
t
L
e
ads
TPA
K
i
4
00
s
M
agnetic Meter Hange
r
A
C Current Clam
p
S
ee
p
a
ge
6
2
S
ee pa
g
e
6
0
Fluke 1587/ET Advanced Electrical
T
rou
bl
es
h
oot
i
ng
Ki
t
i
nc
l
u
d
es
:
Fluke 1587 Insulation Multimeter
Fluke i4
00
C
urrent
C
lamp
Fluke
62
Mini Infrared Thermometer
Fluke 1587
/
MDT Advanced Motor and Drive
Troubleshootin
g
Kit includes
:
Fluke 1
58
7 Insulation Multimeter
Fluke i400 Current Clam
p
Fluke 9
0
4
0
Phase Rotation Indicator
18
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fl
u
k
e
.
co
m
/d
i
s
t
a
n
ce
L
a
s
er
Dis
tance
M
eter
s
Other products
Application tip
Fl
u
k
e 421D, 416D an
d
411D
L
aser Distance Meters
T
he Fluke l
as
er di
s
t
a
n
c
e meter
s
off
er the m
os
t
a
dv
a
n
c
ed me
a
-
s
uring technology available. Unlike ultrasonic distance meters
w
ith laser pointers, these meters use a precision narrow laser
b
eam that helps avoid the common errors caused by extraneous
o
bjects near measurement targets.
E
liminate estimation errors, saving both time and mone
y
Instant measurement with one-button operatio
n
E
asy targeting with bright lase
r
Quick calculation of area
(
square footage) and volume
E
asy addition and subtraction o
f
measurement
s
T
wo-year warranty
Specifications
Ordering information
Included accessories Models
T
wo AAA batteries
,
users manual on CD
,
qu
i
c
k
start gu
id
e, ny
l
on carry
i
ng case.
F
LUKE-421D
L
aser Distance Meter
F
LUKE-41
6
D
L
aser Distance Meter
F
LUKE-411D
L
aser Distance Meter
F
LUKE-411D
/
62
4
11D Laser Distance Meter and
62
IR Thermometer Ki
t
T
hree self-retainin
g
test probes (black),
alligator clip, users manual.
F
LUKE-
90
4
0
R
otar
y
Field Indicato
r
Fluke
416D
Fluke
411D
*
I
n favorable conditions (optimal tar
g
et surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as
intensive sunshine, ver
y
weakl
y
re
f
lectin
g
tar
g
et sur
f
ace, or lar
g
e temperature
f
luctuations, measurin
g
accurac
y
ma
y
d
eteriorate to a
pp
rox. ± 0.25 mm/m (± 0.003 in/ft) for distances above 10 m (33 ft).
**
I
n favorable conditions
(
optimal target surface, room temperature) up to 10 m
(
33 ft). In unfavorable conditions, such as
intensive sunshine, ver
y
weakl
y
reflectin
g
tar
g
et surface, or lar
g
e temperature fluctuations, the deviation over distances
1
0 m (33 ft) can increase b
y
approx. ± 0.15 mm/m 0.0018 in/ft).
Features Fluke 421D Fluke 416D Fluke 411D
R
an
g
e (for extended distances, use
a
target plate)*
0
.
0
5 m to 1
00
m
(
0.16 ft to 330 ft)
0
.
0
5 m to
60
m
(
0.16 ft to 200 ft)
0
.1 m to
30
m
(
0.33 ft to 100 ft
)
Measuring accuracy**
±
1.5 mm
(
± 0.059 in)
±
1.5 mm
(
± 0.059 in)
±
3 mm
(
0.11
8
in
)
Laser class I
I
I
I
I
I
L
aser t
y
pe
63
5 nm
,
< 1 mW
63
5 nm
,
< 1 m
W
63
5 nm
,
< 1 mW
A
utomatic power o
ff
A
fter 180 seconds
a
fter 180 seconds
a
fter 180 seconds
C
ontinuous measurem
e
nt
A
ddition
/
subtraction
B
atter
y
life up to 5,
000
measurements up to
3
,
000
measurements
u
p to
3
,
000
measurements
LC
D illumin
a
ti
o
n
Da
t
a
loca
t
io
n
s
20
1
0
Min
/
Max
A
udible feedb
ack
Pythagoras
(
Indirect measurement)
F
u
ll
F
u
ll
S
im
p
le
R
oom ang
l
e an
d
sta
k
eout
±
45 ° Tilt sensor
/
indirect measure
I
ngress protection
I
P
54
I
P
5
4
I
P4
0
D
imen
s
i
o
n
s
127 mm x
5
2 mm x 29 mm
(
5.00 in x 2.06 in x 1.13 in
)
13
5
mm x 4
6
mm x 31 mm
(
5.31 in x 1.81 in x 1.22 in
)
1
23 mm x
50
mm x 2
6
mm
(
4.84 in x 1.97 in x 1.02 in
)
W
e
i
g
ht
125 g
(
4.40 oz) 110 g
(
3.
88
oz) 150 g
(
5.29 oz)
T
emperature range
S
torage
Operation
-2
5
°C to 7
0
°C
(
-13 °F to 158 °F
)
0
°
C to 40
°
C
(32 °F to 104 °F)
-2
5
°C to 7
0
°C
(
-13 °F to 158 °F
)
0
°
C to 40
°
C
(32 °F to 104 °F)
-2
5
°C to 7
0
°C
(
-13 °F to 158 °F
)
0
°
C to 40
°
C
(32 °F to 104 °F)
O
perating altitude
(
ISO 9022)
up
to 3500
m
up
to 3500
m
up
to 3500 m
S
torage humidity (at 35
°
C)
m
aximum
85
% for 24 h
m
aximum
85
% for 24 h maximum
85
% for 24 h
Batteries AAA
(
2) AAA
(
2
)
A
AA
(
2
)
Fluke
90
4
0
Rotar
y
Field Indicat
or
The Fluke 9
0
4
0
is
a
p
remium
p
hase
r
o
t
a
ti
o
n te
s
ter
with a CAT III
,
6
00 V ratin
g
.
The frequenc
y
ran
g
e is from
1
5
Hz to 4
00
Hz
for demandin
g
applications. The clear
li
qu
id
cr
y
sta
l
di
sp
l
a
y
an
d
t
h
e
h
o
l
ster
make it suitable for rou
g
h outdoor
appli
cat
i
ons.
Thi
s
i
nstrument
i
s
su
ppli
e
d
w
i
t
h
t
h
ree un
iq
ue, ex
p
an
d
-
a
ble test
p
robes that fit most sockets.
I
nc
l
u
d
es a two-
y
ear warrant
y
.
F
or more in
f
ormation, go to
www.fluke.com
/
9040
Wa
y
s laser distance meters
save t
i
me an
d
money
1.
F
a
s
t mea
s
urement
s
:Point. Click.
Th
e measurement
i
s
d
one.
2.
E
asy access
:
Hi
g
h ceilin
g
?
Obstacles in the wa
y
? Just aim
th
e
l
aser.
3.
O
ne man operation
:
Y
our
h
e
lp
er
can
d
o ot
h
er
j
o
b
s.
4.
L
onger
di
stances
:
U
p
to 100
meters (330 feet).
5
.
C
alculation
s
:
Add
an
d
su
b
tract
di
stances.
Fi
n
d
area an
d
vo
l
ume.
E
ven ca
l
cu
l
ate
h
e
igh
t us
i
n
g
Py
t
h
a
g
orean mat
h
.
S
ee why
C
hip Wade and other
experts use distance meters
.
w
ww.fluke.com
/
ldm-vide
o
Recommended kits
Fluke
62
Mini Thermometer
S
oft
p
ouch for each model
19
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/e
gt
Earth Groun
d
Te
s
ter
s
Recommended accessories
Specifications
Ordering information
Included accessories Models
T
est
l
ea
d
s, a
llig
ator c
li
ps, users
manual.
FLUKE-1
625
Advanced GEO Earth Ground Tester
FLUKE-1
623
Basic GEO Earth Ground Tester
T
est
l
ea
d
s, a
llig
ator c
li
ps,
stake/reel set 4-pole, selective
/
stakeless clamp set, rugged
c
arry
i
ng case, users manua
l.
F
LUKE-1
62
5 KIT
A
dvanced
G
E
O
Earth
G
round Tester Ki
t
F
LUKE-1
623
KIT
B
asic
G
E
O
Earth
G
round Tester Ki
t
*
I
n favorable conditions (optimal target surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as
intensive sunshine, ver
y
weakl
y
reflectin
g
tar
g
et surface, or lar
g
e temperature fluctuations, measurin
g
accurac
y
ma
y
d
eteriorate to a
pp
rox. ± 0.25 mm/m (± 0.003 in/ft) for distances above 10 m (33 ft).
**
I
n favorable conditions
(
optimal target surface, room temperature) up to 10 m
(
33 ft). In unfavorable conditions, such as
intensive sunshine, ver
y
weakl
y
reflectin
g
tar
g
et surface, or lar
g
e temperature fluctuations, the deviation over distances
1
0 m (33 ft) can increase b
y
approx. ± 0.15 mm/m 0.0018 in/ft).
Recommended kits
Fl
u
k
e 1625 an
d
1623
G
eo Earth Ground Tester
s
T
hese products are for unpowered installations measuring grounding connections.
T
he Fluke 1
62
5 and 1
623
Earth Ground
T
esters not only measure ground resis
-
tance using the classic “
f
all o
f
potential
test,” but also enable time saving testin
g
using “selective” and “stakeless” methods.
“S
elective” testing does not require the
e
le
c
tr
o
de under te
s
t t
o
be di
sco
nne
c
ted
d
uring the measurement, thus increas
-
i
ng sa
f
ety. The simple “stakeless” method
q
uickly checks ground connections using
two current transformers
(
probes) clamped
around the ground conductor under test.
Offering “one-button” simplicity, the 1
623
i
s an all-in-one earth ground tester, while
the 1
62
5 has extra versatility for more
d
emanding applications
.
T
he 1
623
is perfect for performing pr
e
-
d
i
c
tive m
a
inten
a
n
c
e
c
he
c
k
s
of
co
mmer
c
i
a
l
and industrial applications. The 1
62
5 is
i
ntended
f
or electrical utility or other elec
-
trically noisy environments
.
E
arth
g
round resistance and soil
resistivit
y
should be measured when
:
D
esigning earth ground system
s
I
nstalling new ground system and elec-
trical e
q
ui
p
ment
Periodically testing ground and light
-
ning protection systems
I
nstalling large electrical equipment
s
uch as trans
f
ormers, switchgears,
m
achines, etc
.
Features 1625 1623 1621
One-button measurement concept
3-pole earth ground measurement
4-pole earth ground measurement
4-pole soil resistivity testing
2-pole resistance measurement ac
2-and 4-pole resistance measurement dc
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)
Measuring frequency 128 Hz
Earth impedance measurement at 55 Hz
Automatic frequency control (AFC), 94 Hz to 128 Hz
Measuring voltage switchable 20 V/48 V
Programmable limits, settings
Continuity with buzzer
Dust/water resistance IP 56 IP 56 IP 40
Safety rating CAT II 300 V CAT II 300 V CAT II 600 V
Two-year warranty
Fl
u
k
e
1625
F
luke 1
623
E
I-162
3
EI-162
5
Selective
/
stakeless Selective
/
stakeles
s
clam
p
set for 1623 clam
p
set for 1625
ES-162P
3
E
S-162P4
S
take
/
reel set for
S
take
/
reel set for
3-
p
ole measurement
s
4-
p
ole measurement
s
E
I-1
6
2B
N
Split Core Transformer
for use with Fluke 1
62
5
Fl
u
ke 1
6
25 Ki
t
Fluke 1
6
2
5
teste
r
2 te
s
t le
a
d
s
4
earth ground stake
s
3 cable reels with wire
(
2-25 m, 1-50 m
)
2 clamps (one inducin
g
, one sensin
g
)
R
u
gg
e
d
carr
yi
n
g
case
Fl
u
ke 162
3
Ki
t
Fluke 1
6
23 teste
r
2 te
s
t le
a
d
s
4 earth ground stakes (2-25 m)
3 cable reels with wire
(
2-25 m, 1-50 m
)
2 clamps (one inducin
g
, one sensin
g
)
R
u
gg
e
d
carr
yi
n
g
case
20
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
ES-1
6
2P
3
Earth Stake
S
take
/
reel set for Ground
/
eart
h
3
-pole measurement
s
s
t
ak
e
Application tip
Recommended accessories
Recommended kits
For more in
f
ormation,
g
o to www.fluke.com/e
g
t
Earth Groun
d
Te
s
ter
s
F
luke 1621 Basic Earth Ground Teste
r
Earth ground tester for resistance measurement
T
hese products are for unpowered installations measuring grounding connections.
The Fluke 1630 Earth Ground Clamp Meter is able to measure
g
round loop resistances—using the stakeless testing method.
T
his test technique eliminates the dangerous, and time con
-
s
uming activity, o
f
disconnecting parallel grounds, as well as
t
he process o
f
f
inding suitable locations
f
or auxiliary ground
s
takes. You can also per
f
orm earth ground tests in places you
h
ave not considered be
f
ore: inside buildings, on power pylons
o
r anywhere you don’t have access to soil
.
With the stakeless testing method, the Fluke 1
630
Earth
G
round
C
lamp Meter is placed around the earth ground rod or
t
he connecting cable. No earth ground stakes are used at all.
A
known voltage is induced by one hal
f
o
f
the clamp and the
c
urrent is measured by the other hal
f
. The tester automati
-
c
ally determines the ground loop resistance at this grounding
c
onnection.
G
one are the days of spending time placing and
c
onnecting stakes
f
or each earth ground rod on your system—a
m
ajor time saver
.
Q
uick and easy use—no earth ground stakes are necessar
y
L
arge, 35 mm (1.35 in) jaw opening
M
easures ground resistance from
0
.
02
5
to 15
00
M
easures ground leakage current from
0
.
2
mA to
30
A
High and low alarmin
g
A
ut
o
m
a
ti
c
s
el
f
ca
libr
a
ti
o
n
R
ugged carrying case and resistance check loop included
T
wo-year warranty
T
he Fluke 1
62
1 Earth Ground Tester is a rugged, easy-to
-
use tester
f
or three-pole ground resistance measurements
and two-pole ac resistance measurements.
E
arth ground resistance is measured by install
-
i
ng earth ground test electrodes, and testing with the
F
luke 1
62
1. Earth ground resistance measurements are
used to ensure sa
f
e operation and reduce power qua
l
-
i
ty problems. With a simple user inter
f
ace and intuitive
functionality, the large, clear L
C
D display provides high
visibility results in daylight or poor lighting cond
i
-
tions. The 1
62
1 is lightweight making it ideal to test for
l
ightning protection levels and periodic check-ups during
r
o
utine m
a
inten
a
n
c
e.
T
hree-pole earth resistance measurement
s
T
wo-pole ac resistance measurements
A
C/DC voltage measuremen
t
L
arge dual backlit displa
y
L
imit settings
f
or automatic measurement evaluatio
n
C
AT II
600
V
T
wo-year warranty
Feature comparison on pa
g
e 1
9
.
F
luke 1630 Earth Ground
C
lam
p
Meter
Fluke 1621 Tester
2 cable reels with wire
(
1-50m, 1-25m
)
3
earth ground stakes
1
Test lead
(
red and black 2m)
2 Alligator Clips
H
ard carrying cas
e
C
able Reel 5
0
m
C
able Reel
2
5 m
G
round
/
earth wire
G
round
/
earth wire
(
162.5 ft
)
(
81.25 ft
)
Ordering information
Included accessories Models
T
wo measuring leads with alligator clips, 2 m
(6 ft),
y
ellow protective holster, 9 V alkaline
battery
(
LR61), users manual, CD.
FLUKE-1
6
21 Basic Earth
G
round Tester
1
-5
0
m cable reel
,
1-
2
5 m cable reel
,
3
earth
stakes, 2 test leads, 2 alligator clips, carryin
g
c
ase,
y
ellow protective holster,
9
V alkaline
batter
y
(LR61), users manual, CD
.
F
LUKE-1
62
1 KIT
B
asic Earth
G
round Tester Ki
t
R
u
gg
e
d
carr
yi
n
g
case w
i
t
h
b
e
l
t, res
i
stance
test loop, 9 V battery, users manual
.
FLUKE-1
630
E
arth Ground
C
lamp Mete
r
Wh
at
i
s groun
di
ng, an
d
what does it do
?
The NE
C
, National Electrical
C
ode,
d
e
f
ines a ground as a “conductin
g
c
onnect
i
on, w
h
et
h
er
i
ntent
i
ona
l
or
accid
ent
al
b
etween
a
n e
l
e
c
tr
ical
ci
r
c
u
i
t
o
r equ
i
pment an
d
t
h
e eart
h
, or to some
c
onducting body that serves in place o
f
th
e e
a
rt
h
.
E
art
h
groun
di
ng
i
s an
i
ntent
i
ona
l
c
onnection
f
rom a circuit conductor,
u
sua
ll
y t
h
e neutra
l
, to a groun
d
e
l
ec
-
t
ro
d
e p
l
ace
d
i
n t
h
e eart
h
.
E
qu
i
pment
g
roun
di
ng
i
s to ensure t
h
at operat
i
n
g
equ
i
pment w
i
t
hi
n a structure
i
s proper
l
y
g
roun
d
e
d
.
Th
ese two groun
di
ng systems are
required to be separate except
f
or a
c
onnect
i
on
b
etween t
h
e two systems
t
o prevent di
ff
erences in potential
f
rom
a
possible
f
lashover
f
rom a lightning
strike. The purpose o
f
a ground, besides
t
he protection o
f
people, plants and
equipment, is to provide a sa
f
e path
f
or
t
he dissipation o
f
f
ault currents, ligh
t
-
n
i
ng str
ik
es, stat
i
c
di
sc
h
arges,
EMI
an
d
R
FI signals and inter
f
erence
.
21
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Functions T+PRO T+ T5-1000 T5-600
M
easure ac/dc voltage Preset 12 V
,
24 V
,
4
8
V
,
120 V
,
20
8
V
,
240 V, 277 V
(
Canada 347 V
)
, 4
8
0 V, 600
V
1
000
V
600
V
M
easure ac current (avera
g
e
)
1
00
A1
00
A
M
easure cont
i
nu
i
t
y
Y
e
s
Y
e
s
<
2
5
1
<
2
5
1
M
e
as
ure re
sis
t
a
n
c
e
9
.
99
k
1
1
000
1
1000
1
D
C polarity indicator
Y
e
s
Y
e
s
D
etac
h
a
bl
e pro
b
e t
i
ps w
i
t
h
opt
i
ona
l
pro
b
e t
i
ps st
yl
es
Y
e
s
Y
e
s
Y
es
Y
e
s
D
igital displa
y
Ye
s
No
Yes Ye
s
S
afet
y
ratin
g
CAT IV 600 V
/
CAT III 1
000
V
CAT IV 600 V
/
CAT III 1
000
V
1000
V Overvolta
g
e
C
AT III
600
V Overvolta
g
e
C
AT III
W
arranty Two-year
T
wo-yea
r
Two-yea
r
Two-year
*Voltage levels will vary depending on country o
f
intended use
.
Specifications
Recommended kits
El
ectr
i
ca
l
T
e
s
ter
s
F
or more in
f
ormation,
g
o to www.
f
luke.com/electricaltesters
Fluke T5, T
+
PRO, T
+
E
l
ectr
i
ca
l
Testers and VoltAlert
T+PRO-1A
C
Ki
t
Fluke T+Pro Electrical Tester
1
A
C
-II VoltAler
t
62
/
T+PRO
/
1AC-II
Fluke
62
Non-cont
a
Thermomete
r
T+R
O
Electrical Te
s
1
A
C
-II VoltAlert
Carrying case
Fluke T+PR
O
and
T+ Electrical Testers
T
hree forms of ac/dc voltage detec
-
t
i
on:
Li
g
h
t, soun
d
an
d
v
ib
rat
i
on
Detects live voltage even when
ba
tterie
s
a
re de
a
d
E
xtra heavy-duty, replaceable test
l
e
a
d
s
R
otary
f
ield indicator
f
or trouble
-
s
hooting three-phase systems
C
ontinuity beeper, LED flashlight
and GF
C
I tri
p
Fluke T5 Volta
g
e,
C
ontinuity
and C
u
rrent Te
s
ter
s
E
xcellent front-line troubleshootin
g
and measurement tool
A
vailable in
600
V and 1
000
V model
s
Di
g
ital displa
y
O
p
enJawcurrent measuremen
t
R
otar
y
switch selects volts, amps
and ohms function
s
H
eav
y
-dut
y
test lead
s
Fl
u
k
e
V
o
l
t
Al
er
t
F
am
ily
Th
e next
g
enerat
i
on
V
o
l
t
Al
er
t
ac
non-contact volta
g
e testers from Fluke
a
re eas
y
to use.
El
ectr
i
c
i
ans, ma
i
nt
e
-
nance, service and safet
y
personnel,
a
nd homeowners can quickl
y
test for
ener
gi
ze
d
c
i
rcu
i
ts
i
n t
h
e wor
k
p
l
ace or
a
t home. Certified up to CAT IV 1000 V.
Functions 2AC 1AC-II 1LAC-II LVD2
V
o
l
ta
g
e ran
ge
90
V ac to1
000
V ac
90
V ac to1
000
V ac
20
V ac to
90
V a
c
90
V ac to
600
V a
c
A
u
dibl
e
al
er
t
Fl
as
hli
g
h
t
On
/
Off
Al
ways o
n
S
afety rating
C
AT IV 1
000
V
C
AT IV 1
000
V
C
AT IV 1
000
V
C
AT IV
600
V
T5 Ki
t
C
5
20
A
Starter Ki
t
Premium Leather Holste
r
S
ee pa
g
e
55
S
e
e
pa
g
e
54
H
5
Meter
C
leane
r
E
lectrical Tester Holster
C
leaning Wipes
S
e
e
pa
g
e
54
Ordering information
Included accessories Models
T
he T+ and T+PR
O
come with attached
t
est pro
b
es,
l
ea
d
wrap, users manua
l
.
T+PRO and T+PRO CAN
El
e
c
tr
ical
T
e
s
ter
T+
a
nd T+
C
A
N
El
e
c
tr
ical
T
e
s
ter
T+PRO-1AC KIT
E
lectrical Tester and AC Voltage Detector Kit
T+PRO CAN-1AC KI
T
E
lectrical Tester and AC Voltage Detector Kit
6
2-T+PRO-1AC KIT IR Thermometer, Electrical Tester and AC Voltage
D
ete
c
t
o
r
Ki
t
The T
5
-1
000
and T
5
-
600
come with
d
etac
h
a
bl
e pro
b
es an
d
i
nstruct
i
on s
h
eet
.
T5
-1
000
1
000 V Voltage, Continuity and Current Tester
T5
-
600
6
00 V Voltage, Continuity and Current Tester
T5
-H
5
-1AC KI
T
V
oltage, Continuity and Current Tester Ki
t
2
A
C
Vol
t
Al
er
t
Volta
g
e Detecto
r
2
A
C
5P
K
V
o
l
t
Al
er
t
V
o
l
ta
g
e
D
etector
5
P
ac
k
1A
C
-I
I
Vol
t
Al
er
t
Voltage Detecto
r
1AC-II
5
PK
V
oltAler
t
Volta
g
e Detector 5 Pac
k
1LA
C
-II
V
o
l
t
Al
er
t
V
o
l
ta
g
e
D
etecto
r
LVD2
V
o
l
t
Li
g
ht
T5-1
000
Tester Ki
t
Fluke T5-1
000
Volta
g
e
El
ectr
i
ca
l
T
ester
2
A
C
VoltAlert
V
oltage Detecto
r
F
luke H
5
Holster
V
oltAler
t
Multi Pac
k
Includes
f
ive Fluke VoltAlert
volta
g
e detectors.
T
he special kit pricing gets you the
f
i
f
th VoltAlert
f
ree.
Fluke T5-1000
22
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
For more in
f
ormation,
g
o to www.fluke.com/IA
Q
I
ndoor Air Qualit
y
Recommended kits
Recommended accessories
Specifications
Ordering information
Included accessories Models
C
alibration cap, air velocit
y
probe (Fluke 975V onl
y
), FlukeVie
w
®
Fo
rm
s
so
f
tware, power adapter, international power plu
g
s, hard carr
y
in
g
case,
three AA alkaline batteries, users manual with sa
f
ety in
f
ormation.
F
LUKE-97
5
Ai
r
M
ete
r
FLUKE-97
5
V
A
irMete
r
with Velocit
y
T
wo rubber hoses, soft carr
y
in
g
case, four AA alkaline batteries 1.5 V,
users manual
.
F
LUKE-
922
A
irflow Mete
r
1
2
inch pitot tube, two rubber hoses, ToolPak Ma
g
netic Meter Han
g
in
g
Kit,
hard carrying case,
f
our AA alkaline batteries 1.5 V, users manual
.
F
LUKE-922
/
KIT
A
ir
f
low Meter Kit
922 features Range Accuracy
A
ir
p
ressure ± 4000 Pascals
/
± 16 in H2O
/
± 400 mm H2O
/
± 40 mbar
/
± 0.6 PS
I
±
1 % + 1 Pascal
/
± 1 % + 0.01 in H2O
/
±
1 % + 0.1 mm H2O
/
± 1 % + 0.01 mbar
/
± 1 % +
0
.
000
1 PS
I
Ai
r ve
l
oc
i
ty 250 to16,000 fpm (1 to 80 m
/
s
)
±
2.5 % of reading at 2000 fpm (10.00 m
/
s)
A
ir flow
(
volume
)
0 to 99,999 cfm; 0 to 99,999 m 3
/
hr; 0 to 99,999 l
/s
Accuracy is a function of velocity and duct size
T
em
p
erature 0 °C to 50 °C
(
32 °F to 122 °F
)
0
.1 °C
(
0.1 °F
)
D
ata storag
e
9
9 readings
Warrant
y
T
wo-yea
r
P
o
we
r
F
o
ur AA b
a
tterie
s
Fl
u
k
e 975 A
i
rMeter
Simple, one-touch air velocity
The Fluke
9
75 AirMete
r
combines
f
ive power
f
ul air
quality tools into one. Identi
f
y and diagnose indoor
a
ir quality issues quickly and easily with one rugged,
handheld device. The Fluke
9
75 measures and simulta
-
n
eously displays temperature, humidity,
C
O2 and
CO
. At
the press o
f
a button, it quickly measures air
f
low and
percentage o
f
outside air
.
S
imultaneously measures, logs and displays
temperature, humidity,
C
O
2
and
C
O on a bright,
backlit L
C
D display
%
of
o
ut
s
ide
a
ir
ca
l
c
ul
a
ti
o
n
O
ne-touch air flow and velocity with available
probe*
D
ew point and wet bulb temperatur
e
CO
2
and
CO
field calibration feature
M
in/Max/Avg on all measured and calculated
reading
s
A
udible
a
nd vi
s
u
a
l thre
s
h
o
ld
a
l
a
rm
s
E
xtensive discrete or continuous data logging
c
apacity, downloadable to P
C
via USB interfac
e
In
c
lude
s
NI
S
T-tr
ac
e
a
ble
c
ertifi
ca
te
o
f
ca
libr
a
ti
o
n
A
utomatically compensates
f
or barometric pressure
c
hanges
Two-year warranty
*Included with Fluke 975V, o
p
tional with Fluke 975
.
975 features Range Display resolution Accuracy
T
emperature
-
20
°
C to 50
°
C
(
-5
°
F to 122
°
F) 0.1
°
C (0.1
°
F)
±
0.9 °C
/
± 1.62 °F from 40 °C to 60 °C ± 0.5 °C
/
± 1.00 °F from 5 °C to 40 °C ± 1.1 °C
/
± 1.98 °
F
f
rom -2
0
°C to
5
°
C
Relative humidit
y
1
0
% to 9
0
% RH
non-con
d
ens
i
n
g
1
%
± 2 % RH
(
10 % RH to 90 % RH
)
A
ir velocit
y
50
.
0
fpm to
3000
fpm
0
.25 m
/
sec to 15 m
/
se
c
1
f
p
m (0.005 m/sec
)
±
4 % or 4 fpm* ± 4 % or 0.02 m/sec* whichever is
g
reater * Accuracy speci
f
ication only valid
f
or velocit
y
readings above 50 fpm
CO
2
0
to 5
000
pp
m
1
ppm
W
arm up time 1 min (5 minutes for full specification)
2
.75 % + 75
pp
m
C
O
0 to 500
pp
m
1
pp
m
±
5 % or ± 3 ppm, whichever is greater,
@
20 °C and 50 % RH
Fluke 922 Airflow Meter/Micromanomete
r
M
ake air
f
low measurements eas
y
b
y
combinin
g
di
ff
erential pressure, air
f
low, and velocit
y
into a sin
g
le, ru
gg
ed meter. Used with an
y
pitot tube,
the Fluke 922 is the perfect entr
y
point for technicians measurin
g
air
f
low
f
or the
f
irst time,
y
et power
f
ul enou
g
h
f
or advanced users.
M
easures di
ff
erential and static pressure, air velocit
y
and
f
low
readin
g
s
User-de
f
ined duct shape and size
f
or maximum air
f
low accurac
y
B
ri
g
ht, backlit displa
y
M
in/Max/Av
g
/Hold functions
A
uto
p
ower o
ff
Fluke-
9
75V
P
A
irMeter Velocity Probe for use with Fluke 975 AirMeter.
Fl
u
ke-975C
K
A
irMeter
C
alibration Kit includes the
g
ases and tools
necessar
y
to keep
y
our Fluke
9
75 AirMeter calibrated.
Fluke 922
/
Kit
A
ir
f
low mete
r
12
inch
p
itot tube
Two rubber hoses
TPak magnetic strip
TPak stra
p
, 9 inches
TP
a
k l
a
t
c
h t
ab
F
our
AA
1
.
5
V
a
lk
a
li
ne
b
atter
i
es
Us
er
s
m
a
nu
al
H
ar
d
carry
i
ng cas
e
Fluke
9
75
V
A
irM
e
t
er
C
alibration ca
p
A
ir velocity probe
Fl
u
k
e
Vi
e
w
®
F
o
rm
s
so
ftw
a
re
P
ower a
d
apte
r
I
nternat
i
ona
l
power p
l
u
g
s
H
ar
d
carr
yi
n
g
case
T
hree AA alkaline batterie
s
Users manual with sa
f
et
y
in
f
ormatio
n
23
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/IA
Q
I
ndoor Air Qualit
y
Specialty models
Ordering information
Included accessories Models
C
ertificate of Calibration (NIST), Windows compatible software
download utilit
y
, DB
9
to RS-
232
adapter and cable, isokinetic
probe, high purity tubing, 1/8 inch hose barb adapter, power
s
upply, zero count filter, protective holster and hard molded
p
l
ast
i
c case, users manua
l.
F
LUKE-9
83
P
a
rti
c
le
Co
unter
F
our
AAA
a
lk
a
li
ne
b
atter
i
es, users manua
l
.FLUKE-
9
7
1
T
emperature
H
um
idi
t
y
M
eter
FLUKE-9
8
3TPK 22
0
Thermal Printer Kit, 220
V
FLUKE-9
8
3TPK 12
0
Thermal Printer Kit, 120
V
FLUKE-CO-2
05
A
s
pi
rator
Ki
t
FLUKE-CO-22
0
Ca
rb
o
n M
o
n
o
xide Meter
FL
U
KE-RLD2
R
efrigerant Leak Detector Flashlight
I
ndoor Air Qualit
y
Tool
s
Tools to help you maintain good IAQ
Fluke 971 Temperature Humidity Mete
r
T
emperature and humidity are two important factors in maintai
n
-
i
ng optimal comfort levels and good indoor air quality.
Q
uickly
an
d
conven
i
ent
l
y ta
k
e accurate
h
um
idi
ty an
d
temperature rea
d
-
i
ngs with the Fluke
9
71. The Fluke
9
71 is invaluable for facility
m
aintenance and utility technicians, HVA
C
-service contractors,
and specialists who assess indoor air quality
(
IAQ). Lightweight
and easy to hold, the Fluke
9
71 is the perfect tool for monitoring
p
ro
bl
em areas.
Wi
t
h
a rugge
d
h
o
l
ster an
d
tw
i
st-open protect
i
ve
s
ensor cover, the Fluke
9
71 is built to perform and made to last
.
F
eatures:
N
ew and improved digital sensor for faster response times
B
acklit dual display of humidity and temperatur
e
M
easures
d
ew po
i
nt an
d
wet
b
u
lb
temperature
s
99
record storage capacit
y
E
rgonom
i
c
d
es
i
gn w
i
t
h
b
e
l
t c
li
p an
d
protect
i
ve
h
o
l
ste
r
Compact and lightweight at 1
88
g
(
6.6 oz
)
T
emperature range from -20 °C to 60 °C (-4 °F to 140 °F)
R
elative humidity from 5 % to
9
5 %
M
in
/
Max
/
Avg
/
Hold functions
L
ow
b
attery
i
n
di
cator
One-year warranty
Fluke RLD2 UV Refrigerant
L
eak Detector Flashli
g
ht
L
e
a
k dete
c
ti
o
n m
a
de
easy. The compact,
easy-to-use, RLD
2
UV
f
lashlight uncov
-
ers re
f
rigerant leaks
i
nstantly. Use the UV
l
ight to
f
ind the lea
k
-
a
ge area, then, use the
l
aser pointer to pinpoint
t
he ex
ac
t le
a
k l
oca
ti
o
n.
With 1
00
,
000
hours of
l
i
f
e, and
f
our operatin
g
modes, this versatile
l
e
a
k dete
c
t
o
r i
s
a
mu
s
t
ha
ve f
o
r HVA
C
te
c
hni
c
i
a
n
s
.
S
ix UV LEDs
(
395 nm wavelength)
d
etect leak detection dye
s
L
aser pointer clearly locates center
of
the UV
f
ield
f
or accuracy
Three LED flashlight with 1
00
,
000
ho
ur LED li
f
e
Operating temperature 0
°
C to 50
°C
F
our operating modes:
f
lashlight,
UV light, laser light, UV
/
laser light
co
m
bi
n
a
t
io
n
C
onvenient detachable key chain
c
ara
bi
ner an
d
AAA
b
attery
i
nc
l
u
d
e
d
C
O-
220
C
ar
bo
n
Mo
n
o
x
id
e
M
eter
S
tand-alone C
O
meter
t
hat does not re
q
uire a
d
i
g
ital multimeter
L
ar
g
e backlit LCD dis
-
p
la
y
s CO levels from 0 to
1000
ppm
Beeper tri
gg
ers with
i
ncreasin
g
f
requenc
y
as
C
O
levels rise
M
AX hold
f
unction
stores and displa
y
s the
maximum C
O
leve
l
A
utomatic sensor zer
o
-
i
n
g
and sel
f
-test upon
startu
p
CO-205 Aspirator Kit
The CO-205 flue
g
as samplin
g
a
ccessor
y
ki
t
i
nc
l
u
d
es
:
Stainless steel sampling tube
A
spirator
R
ep
l
acea
b
filte
r
N
ose cap
c
onnect
io
th
e
Fl
u
k
e
CO-210/CO-220
Fluke 983 Particle Counte
r
T
he Fluke 9
8
3 Particle Counter measures and displays
s
ix channels of particle size distribution. The Fluke 9
8
3
h
olds 5
000
logged samples including date, time, counts,
s
amp
l
e vo
l
ume, temperature an
d
re
l
at
i
ve
h
um
idi
ty.
D
ata
i
s eas
il
y
d
own
l
oa
d
e
d
us
i
ng t
h
e
i
nc
l
u
d
e
d
w
i
n
d
ows
c
ompatible utility software. The Fluke 9
8
3 is invalu
-
able for IA
Q
investigations, allowing you to determine
s
ize distribution of airborne particles or track down a
p
art
i
c
l
e source
.
F
eatures:
C
ompact and easy to operat
e
G
raphic liquid crystal display with backligh
t
S
imple connection to computer or printe
r
S
electable sample time, count data and programmable
d
e
l
ay
S
et sample size to cubic feet or liters, set temperature
m
easurements to °C or °
F
D
ata
di
sp
l
aye
d
i
n tota
li
ze or concentrat
i
on mo
d
e
s
A
utomatic turn-off when battery voltage drops below
s
afe operating level
M
eets JISB
992
1:1
99
7 and
C
E standards
B
attery or ac operat
i
on w
i
t
h
i
nterna
l
rec
h
argea
bl
e
b
atter
y
P
rotect
i
ve
h
o
l
ste
r
R
ugge
d
,
h
ar
d
s
h
e
ll
carry
i
ng cas
e
One-year warranty
24
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
For more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/
1507
I
nsu
l
at
i
on
R
es
i
stance
T
est
i
n
g
Recommended accessories
Specialty models
F
luke 1507/1503 Insulation Resistance Tester
s
Troubleshooting and predictive maintenance tools
Selection guide
Ordering information
Included accessories Models
R
emote pro
b
e, test
l
ea
d
s, test
probes, alli
g
ator clips, holster,
users manual
.
FLUKE-15
0
7
I
n
s
u
la
t
io
n
T
e
s
ter
FLUKE-1
503
I
n
s
u
la
t
io
n
T
e
s
ter
S
oft carrying pouch,
us
er
s
m
a
nu
al
.
F
LUKE-3
60
A
C Leakage Current Clamp Mete
r
Features 1555 1550C 1507 1503 1587 1577
Insulation test volta
g
es 5
0
V,
1
00
V
,
2
5
0
V
,
5
00
V
,
1
000
V
Insulation test voltages
500
V, 1
000
V
Insulation test voltages: User
selectable 250 V to 5000 V
Insulation test voltages: User
selectable 250 V to 10,000 V
Insulation resistance
2
T
1
T
0
.
0
1 M to
1
0
G
0
.1 M to
2
G
0
.
0
1 M to
2.
0
G
0
.1 M to
600
M
Auto-discharge of capacitive
v
o
l
ta
g
e
Insulation test smoothin
g
r
eading
F
requenc
y
C
apacitance
Diod
e te
s
t
T
em
p
eratur
e
M
in
/
Max
Low-
p
ass filter
(
for work
on VSDs
)
A
C/DC volta
g
e
D
C
millivolts
A
C
/
DC milliamps
R
es
i
stanc
e
0
.1
to
20
.
00
K
0
.1
to
20
.
00
K
0
.1
to
50
M
0
.1
to
50
M
C
ontinuit
y
Warrant
y
(
y
ears
)
3
3
1
1
3
3
R
emote probe, test leads,
a
lligator clips ••
T
ype
K
t
h
ermocoup
le
R
ugge
d
, ut
ili
ty
h
ar
d
cas
e
A
uto
p
ower off
P
age number 2
5
2
5
24
24
17
17
T
hese lightweight, a
ff
ordable insulation testers are per
f
ect
f
or troubleshooting, commissioning and preventive mainte
-
nance applications.
F
eat
u
re
s
A
utomatic calculation o
f
polarization index and dialec
-
tric absorption ratio (1507 only)
M
ultiple test voltages: 5
0
V, 1
00
V,
2
5
0
V, 5
00
V, 1
000
V
(
1507 only)
R
emote test probe
f
or rapid testing
I
nsulation test range 0.01 M to 10 G (1507), 0.1 M to
2000 M
(
1503
)
C
ompare (Pass/Fail) function for repetitive tests
(
1507 only)
L
ive circuit detection prevents insulation test i
f
voltage
>
30
V is detected
A
uto-discharge o
f
capacitive voltage
A
C/DC voltage: 0.1 V to 600 V
L
o ohms/Earth-bond continuity (200 mA) for checking
c
onnections and motor winding
s
R
esistance:
0
.
0
1
to
20
.
00
O
ne-year warranty
C25 C101
Meter
Case
H
a
rd
Case
S
ee
p
a
ge
54
S
e
e
p
a
ge
54
TPAK
T
L225
M
agnet
i
c
M
eter
H
ange
r
S
tray Voltage Adapter
S
ee
p
a
ge
62
T
est
L
ea
d
Kit
Fluke 360 AC Leakage
C
urrent
C
lam
p
Meter
Ca
l
c
ul
a
te in
s
ul
a
ti
o
n re
s
i
s
t
a
n
c
e while
equ
i
pment
i
s un
d
er
l
oa
d
b
y measur
-
i
ng
i
nsu
l
at
i
on
l
ea
k
age
c
urrent.
Th
e un
i
que
j
aw design o
f
the Fluke
360
eliminates the
i
n
f
luence o
f
adjacent
c
urrent
co
n
d
u
c
t
o
r
s
a
n
d
measures
l
ea
k
age cur
-
rent down to 1 A
f
or
monitoring o
f
insul
a
-
ti
on.
Th
e ergonom
i
c
d
esign of the Fluke
360
e
n
sures easy measur
-
i
ng.
Th
e measur
i
ng
c
lamp
f
its into tight
spaces an
d
t
h
e w
id
e
di
sp
l
ay ang
l
e c
l
ear
l
y
sho
w
s
t
h
e me
as
ur
e
-
ment re
s
u
l
t.
Th
e
Da
t
a
Hold
b
utt
o
n
k
eeps t
h
e measure
d
va
l
ue on t
h
e
d
isplay a
f
ter removing the clamp
f
or
th
e me
as
ure
d
co
n
d
u
c
t
o
r.
The Fluke
360
offers the widest
range o
f
current measurement. Use
t
he rugged Fluke
360
when its not
p
oss
ibl
e to power
d
own an
d
b
rea
k
t
h
e
ci
r
c
u
i
t
.
C
u
rrent mea
su
remen
t
A
utomat
i
c rang
i
ng w
i
t
hi
n t
h
e
manua
ll
y se
l
ecte
d
m
A
or
A
range
R
anges 3
/
30 mA and 30
/
60
A
Current resolution 1 µA
/
0.01 mA
a
nd 0.01 A
/
0.1
A
F
requency range 5
0
and
60
H
z
Jaw size: 40 mm
(
1.55 in
)
maximum
co
ndu
c
t
o
r di
a
mete
r
A
uto power o
ff
25
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/
1550
I
nsu
l
at
i
on
R
es
i
stance
T
est
i
n
g
Recommended kits
Application note
I
nsu
l
at
i
on res
i
stance test
i
n
g
I
nsu
l
at
i
on
res
i
stance
t
es
t
ers can
b
e use
d
to
d
eterm
i
ne
th
e
i
ntegr
i
ty
o
f windings
o
r ca
bl
es
i
n motors
,
t
ransformers
,
sw
i
tc
h
-gear,
a
n
d
e
l
ectr
i
ca
l
i
nsta
ll
at
i
ons.
Th
e test
met
h
o
d
i
s
d
etermined by the type of equi
p
-
m
ent being tested and the reason for
t
est
i
ng.
F
or
i
nstance, w
h
en test
-
i
ng e
l
ectr
i
ca
l
ca
bli
ng or sw
i
tc
h
gear
(
low-capacitance equipment) the
ti
me-
d
epen
d
ent capac
i
t
i
ve
l
ea
k
-
a
ge an
d
a
b
sorpt
i
on
l
ea
k
age currents
b
ecome insignificant and decrease
t
o zero a
l
most
i
nstant
l
y.
A
stea
d
y
c
onductive leakage current flow is
reached almost instantly
(
a minute or
l
ess
)
providing perfect conditions for
t
he spot-reading
/
short-time resis
-
t
ance
t
es
t.
www.fluke.com
/
IRT
Power
f
ul troubleshooting and
p
redictive maintenance tool
s
T
he new Fluke 1555 and redesigned Fluke
1
55
0C
insulation resistance testers offer
d
igital insulation testing up to 1
0
kV, mak
-
i
ng them ideal
f
or testing a wide range o
f
h
igh voltage equipment including switchgear,
m
otors, generators and cables.
T
est voltages up to 5 kV
(
1550C) and
1
0 kV
(
1555) provide solutions for all
application
s
Warning
f
unction alerts the user that line
voltage is present and gives a voltage
reading up to
600
V ac or dc for increased
user sa
f
et
y
M
easurements can be stored in up to
99
m
emory locations, and each location is
assigned a unique, user-de
f
ined label
f
or
e
asy recal
l
L
ong battery life gives the user over 75
0
tests between change
s
A
utomatic calculation o
f
Dielectric Absorp
-
tion
(
DAR
)
and Polarization Index
(
PI
)
with
no a
ddi
t
i
ona
l
setup
G
uard system eliminates the effect of sur
-
f
ace leakage current on high-resistance
m
e
as
uremen
ts
L
arge digital
/
analog LCD for easy viewin
g
C
apacitance and leakage current
m
e
as
uremen
t
R
amp
f
unction
f
or breakdown testing
Th
ree-year warranty
Functions Range Accuracy (± reading)
L
eakage curren
t
1
nA t
o
2 m
A
±
(
5 % + 2 nA
)
C
a
p
acitance measurement
0
.01 uF to 15.00
µF
±
(
15 % rdg + 0.03 µF
)
Li
ve
ci
r
c
u
i
t
i
n
dica
t
or
30 V to 600 V ac
/
dc, 50
/
60 Hz ±
(
5 % + 2 V
)
T
he tester’s accurac
y
is specified for one
y
ear after calibration at operatin
g
temperatures of 0
°
C to 35
°
C. For operatin
g
tempera
-
t
ures outside the ran
g
e (-20
°
C to 0
°
C and 35
°
C to 50
°
C), add ± .25 % per
°
C, except on the 20 % bands add ± 1 % per
°
C.
1
555 and 1550C Insulation
R
esistance Testers
1
550C
/
Kit includes
:
1
55
0C
insulation resistance teste
r
Ruggedized alligator clips
I
P
6
7 hard cas
e
NI
S
T traceable certificate of calibration
1
555
/
Kit includes:
1555
insulation resistance teste
r
Ruggedized alligator clips
I
P
6
7 hard cas
e
NI
S
T tr
ac
e
a
ble
c
ertifi
ca
te
o
f
ca
libr
a
ti
o
n
Insulation resistance measurement
Test voltage (dc) Range Accuracy (± reading)
2
5
0
V
<
200
k
2
00
k to
5
G
5
G to
50
G
>
5
0
G
u
nspeci
f
ied
5
%
20
%
u
nspecified
500
V
<
200
k
200
k
to 1
0
G
10
G to 1
00
G
>
1
00
G
u
nspecified
5 %
20
%
u
nspecified
1000
V
<
2
00
k
200
k
to
20
G
20
G
to
200
G
>
2
00
G
u
nspecified
5 %
20
%
u
ns
p
ecified
2
500
V
<
2
00
k
2
00
k to
50
G
5
0
G
to 5
00
G
>
500
G
u
ns
p
eci
f
ied
5
%
20
%
u
ns
p
eci
f
ied
5
000
V
<
200
k
200
k to 1
00
G
1
00
G
to 1 T
>
1 T
u
ns
p
eci
f
ied
5
%
20
%
u
nspeci
f
ied
1
0000 V (1555 Onl
y
)
<
200
k
200
k to 2
00
G
200
G to 2 T
>2T
u
nspeci
f
ied
5
%
20
%
u
nspecified
Specifications
Ordering information
Included accessories Models
T
est
l
ea
d
s w
i
t
h
a
llig
ator c
li
ps, ru
gg
e
di
ze
d
a
llig
ator c
li
ps
(kits and 1555 onl
y
), infrared adapter with interface
cable, FlukeView Forms so
f
tware, ac
p
ower cord, so
f
t
carrying case, quick reference guide, users manual
.
FLUKE-155
0C
5
kV
I
nsu
l
at
i
on
T
este
r
FLUKE-1550C
/
Kit
5
kV
I
nsu
l
at
i
on
T
ester
Kit
FLUKE
-
1555
1
0
kV Insulation Teste
r
FLUKE-1555
/
Ki
t
1
0
kV Insulation Tester Kit
26
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
For more in
f
ormation,
g
o to www.fluke.com/p
q
P
ower Quality Analyzers
F
luke 345 Power Qualit
y
Clam
p
Meter
The ideal meter to troubleshoot modern electrical loads
Basic measurements Application use
Single Phase Three Phase
VR1710 345 43B 1735 1740 430 1750 1760
Energy studies
M
easure V
,
I
,
kW
,
Cos/
DPF
,
kWh
r
Get detailed
p
ower and
e
nergy consumpt
i
on
p
rofiles durin
g
ener
gy
audits and
p
in
p
oint
s
avings opportunities.
M
easure MIN
/
MAX and
A
V
G
values
10 day logging
Basic harmonics study
T
HD me
as
urement
(
V & I
)
Di
sco
ver the
so
ur
c
e
of distortion in you
r
i
nsta
ll
at
i
on, so t
h
at
y
ou
can
f
ilter those loads o
r
move t
h
em to se
p
arate
ci
r
c
u
i
t
s
.
H
armonics 1 to
2
5
for V & I
Advanced harmonics stud
y
Full harmonic spectrum
If
distortin
g
loads are
c
ausing problems in
your
i
nsta
ll
at
i
on, you
n
ee
d
compre
h
ens
i
ve
d
ata to identi
fy
the
so
ur
c
e
a
nd
c
re
a
te
a
sol
ut
io
n
.
Po
wer h
a
rm
o
ni
cs
Basic industrial P
Q
troubleshootin
g
*
O
scilloscope function
Wh
en trou
bl
es
h
oot
i
ng
in the field,
g
raphical
d
ata enables
y
ou to
t
r
ac
e the
so
ur
c
e
o
f the
pro
bl
em at
h
an
d.
V
o
l
tage
di
ps an
d
swe
ll
s
A
dvanced industrial P
Q
troubleshootin
g
**
C
omprehensive logging
capa
bili
t
y
Complex installations
o
ften require a deeper
dive into measurement
data. Multi
p
le loads
m
a
y
b
e
i
nteract
i
n
g
r
andoml
y
to cause a
single problem.
T
ransient ca
p
ture
Flicker
Selection guide
T
he Fluke
3
45 is more than a power meter.
C
ombining the
f
unctions o
f
a clamp meter, oscilloscope, data logger and digital
power meter into one handy device, the Fluke
3
45 is ideal for
w
orking with variable
f
requency motor drives, high e
ff
iciency
lighting and other loads using switching electronics
.
AC
/
DC current:
C
lamp-on measurement of ac current up to
1
4
00
A rms and dc current up to
2000
A without breaking the
c
ir
c
uit
Highest sa
f
ety rating
:
600
V
C
AT IV power analyzer is rated
fo
r u
s
e
a
t the
s
ervi
c
e entr
a
n
ce
Accurate in nois
y
environments:
C
lamp meter performs even
w
ith distorted wave
f
orms present on electronic loads with
low-pass
f
ilter
D
ata logging
:
Identi
f
y intermittent
f
aults by logging any
power quality parameter
f
or minutes, or over a month, includ
-
ing harmonic
s
V
eri
fy
batteries: Direct measurement of dc ripple
(
%) for ba
t
-
tery and dc system
s
Troubleshoot harmonics
:
Analyze and log harmonics digitally
or graphicall
y
Inrush current:
C
apture and analyze nuisance tripping, from
3
s
econds to
300
second
s
E
as
y
to use: Easily con
f
irm power meter setup with large
backlit color display o
f
wave
f
orms and trends
V
iew graphs and generate reports
:
Use power analyzer with
included Power Log so
f
twar
e
Ordering information
Included accessories Models
T
est leads, alligator clips, test probes, Power Log software, U
S
B
cable, international ac adapter
/
batter
y
eliminator, soft carr
y
in
g
case, users manual, multi-language manual CD.
FLUKE-34
5
Clamp-On Power Mete
r
Set u
p
and troubleshoot variable
frequenc
y
drives and UPS s
y
stems
Veri
f
y correct operation by measuring
k
ey parameter
s
H
armonics measurements
U
n
co
ver
h
armonic issues that can damage or
d
isrupt critical equipmen
t
I
nrush ca
p
ture
C
heck start-up cu
r
-
rent where spurious resets or nuisance
c
ircuit breaker tripping occur
s
L
oad studies – Veri
f
y electrical system
c
apacitybe
f
ore adding loads
E
quipment performance measurement—power consumed
by
s
i
n
gl
e- an
d
t
h
ree-p
h
ase
b
a
l
ance
d
l
oa
d
s
.
View wave
f
orms
f
or equipment checking and setup.
T
LK2
91
C
55
0
Fu
s
ed Te
s
t Pr
o
be
S
e
t
Tool Ba
g
S
ee pa
ge
54
T
P220 AC220
I
n
d
u
s
tr
ial
T
e
s
t
P
r
ob
e
s
Alligator Clips
S
e
e
p
a
ge
57
S
ee pa
g
e
57
Application tip
For more information and detailed product selector go to:
http:
//
www.fluke.com
/
fluke
/
usen
/
products
/
prodselection?product=pqt&cate
g
ory=pqtto
p
27
Recommended accessories
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Resources
What’s included
F
or more in
f
ormation,
g
o to www.fluke.com/pq
P
ower Quality Analyzers
F
luke 430 Series Three-Phase
P
ower Quality Analyzer
s
Pin
p
oint
p
ower
p
roblems
f
aster, sa
f
er and
i
n
g
reater detail
T
he Fluke 4
3
5 and 4
3
4 Three-Phase Power
Q
ual
-
i
ty
A
na
l
yzers
h
e
l
p you
l
ocate, pre
di
ct, prevent an
d
troubleshoot problems in three- and single-phase power
d
istribution systems. Troubleshooting is
f
aster with
o
n-screen display o
f
trends and captured events, even
w
hile background recording continues.
L
o
gg
ed data analysis: PowerLog so
f
tware provide
d
ownload, analysis reporting in minute
s
A
utoTrend: Every measurement you see is always
automatically recorded, without any setu
p
A
utomatic Transient Mode:
C
apture
200
kHz wav
e
-
form data on all phases simultaneously up to
6
k
V
F
ull
y
C
lass-A compliant
:
C
onduct tests according to
the stringent international IE
C
6
1
000
-4-
30
C
lass-A
s
t
a
nd
a
r
d
I
nrush mode: For troubleshooting nuisance circuit
b
reaker trippin
g
L
o
gg
er
f
unction
:
C
onfigure for any test condition
w
ith memory for over 4
00
parameters at user defined
i
nterv
a
l
s
Features 435 434*
M
easures volta
g
e, current, dips, swells,
interru
p
tions, harmonics, inter-harmonics, flicker,
p
ower, ener
gy
, transients, frequenc
y
, unbalance,
inrush
,
EN5
0
1
60
overview
L
ogger function with multi-parameter logging
O
ptional
*
M
a
i
ns s
ig
na
li
n
g
Optional
*
Memor
y
size 1
6
MB
8
M
B
Current
p
robes 3000 A flexible
(
4
)
40 A/400 A clam
p
(4)
C
arrying cas
e
W
ater-t
i
g
h
t
h
ar
d
case w
i
t
h
ro
ll
ers
R
ugge
d
h
ar
d
case
So
ftw
a
r
e
Fl
u
k
e
P
ower
L
o
g
an
d
Fl
u
k
e
Vi
ew
®
FlukeVie
w
®
Th
ree-
y
ear warrant
y
*
O
ptional functionality can be added with upgrade kit.
More PQ info online at
www.fluke.com/pq
Get a free P
Q
training DVD
w
ww.fluke.com
/
PQ-DVD
Sign up for a P
Q
seminar
w
ww
/
fluke.com
/
FPQseminar
T
roubleshoot real-time:
A
nalyze the trends
using the cursors and
z
oo
m t
oo
l
s
even while
b
ackground recording
co
ntinue
s
Mea
s
ure all three
phases and neutral
:
With in
c
luded
fo
ur
c
u
r
-
rent
p
robes
S
y
stem-Monitor
:
U
p
to ten
p
ower
q
ua
l
-
i
t
y
parameters on one
s
creen accordin
g
to
E
N50160 power qualit
y
s
t
a
nd
a
r
d
Features
Ordering information (basic versions do not include current probes)
Included accessories Models
F
our flexible current probes (i430 Flex), five test leads and
clips, batter
y
char
g
er, FlukeView so
f
tware, Power Lo
g
so
f
tware,
optical U
S
B cable, color localization set, hard carrying case with
rollers,
g
ettin
g
started manual, users manual on CD.
FLUKE-4
35
T
hree-Phase Power
Q
ualit
y
Anal
y
ze
r
Four current probes (i400s), five test leads and clips, battery
c
har
g
er, FlukeView software, optical USB cable, color
localization set, hard carr
y
in
g
case,
g
ettin
g
started manual,
us
er
s
m
a
nu
a
l
o
n
C
D.
F
LUKE-4
3
4 Three-Phase Power Quality Analyze
r
C
435 GPS430
Water-tight hard
G
PS time
cas
e w
i
t
h
r
oll
er
s
sync
h
ron
i
zat
i
on mo
d
u
le
I5sPQ
3
i430-flex-4p
k
3
p
ack of 5 A
p
recision
4
p
ack of 3000
A
c
urrent c
l
am
ps
flexible current
p
robe
s
F
l
u
k
e
4
35
28
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Application tip
Recommended accessories
F
luke 43B Power Qualit
y
Anal
y
zer
Power quality analysis plus a scope and a meter
Fluke 4
3
B Power
Q
uality Analyzer performs the
s
urements you need to maintain power systems,
b
leshoot power problems, and diagnose equipment
u
res. The 4
3
B has
20
storage locations and can store
as
well
as
sc
reen
s
.
a
sic measurements
:
Voltage, current, and power
a
rmonics up to 51st, THD
s
cilliosco
p
e function
:
View voltage and current
wa
ve
fo
rm
s
r
ansients
:
C
apture up to 4
0
voltage transients and
wa
ve
fo
rm event
s
e
tailed event ca
p
ture
:
C
ursors give time and date o
f
a
gs and swells
l
ukeVie
w
® so
f
tware: Analysis and reporting, supplied
w
ith
US
B
co
nne
c
ti
o
n le
a
d
a
tter
y
operated
:
6
.5 hours of operation from NiMH
a
tter
y
W
arrant
y
:Three-years
f
or analyzer, one-year
f
or
cc
e
sso
rie
s
Fluke Norma 4000 and 5000 are ideal
f
or
f
ield and laboratory testin
g
F
luke Norma Analyzers o
ff
er easy and straight-
f
or
-
w
ard operation with unmatched price per
f
ormance.
F
eatures include: 1 to 6 power phases, 5.7 in
/
144
m
m co
l
or
di
sp
l
ay,
h
armon
i
c ana
l
ys
i
s, scope mo
d
e,
vector diagram display, recorder
f
unction, Fluke
No
rm
a
View P
C
so
ftw
a
re
a
nd 4 MB RAM d
a
t
a
me
m
o
ry
.
Fluke
Norma
4000
Fl
u
k
e Norma 4000 an
d
5000
P
recision Power Analyzer
s
The hi
g
h speed oscilloscope
c
apabilit
y
is particular use
f
ul
fo
r
s
ervi
c
e
a
nd
co
mmi
ss
i
o
n
of
electronic switchin
g
loads
.
T
he inru
s
h
sc
reen
s
h
o
w
s
the effe
c
t
s
o
f
l
oa
d
start up.
T
he wide band scope can displa
y
the
d
etails o
f
PWM drives wave
f
orms
.
C
hoose the right model for your application: a variety o
f
standard con
f
igurations
allows users to choose the exact
f
unctionality required
f
or their unique application
Electrical measurement integrity and sa
f
ety: inputs are galvanically isolated to
avoid short circuits in all applications and simultaneous parallel acquisition o
f
all
p
hases allows accurate viewing of dynamic events dc to 3 MHz/10 MHz bandwidth for
reliable measurement precisio
n
Voltage, current and power harmonics FFT analysis: to the 4
0
th harmonic, vector
d
iagram, and Digital Oscilloscope (DSO) mode included in the base unit for complete
analysis capabilit
y
C
omplete electrical and mechanical anal
y
sis: PI1 process inter
f
ace to measure
torque and speed with external sensors,
p
lus
f
our analog outputs
f
or easy use on
m
otor and drive applications
Data download, anal
y
sis and report
writing with: supplied Fluke Norma
-
View P
C
so
ftw
a
re
Fluke
Norma
5000
For more in
f
ormation,
g
o to www.fluke.com/p
q
P
ower Quality Analyzers
Ordering information (basic versions do not include current probes)
Included accessories Models
Volta
g
e and current probes, FlukeView
®
software, power qualit
y
i
nstructional CD, USB interface cable, line volta
g
e adapter/
b
attery charger, hard case, users manuals.
FLUKE-4
3
B
P
ower
Q
ualit
y
Anal
y
zer
Power supply cable, NormaView PC software, test certificate,
c
a
lib
rat
i
on va
l
ues, users manua
l.
N
orma 4
000
H
igh Precision Power Analyze
r
N
orma 5
000
H
i
g
h Precision Power Anal
y
ze
r
i5
s
100
A
AC
C
urrent
C
lam
p
Shunt with
C
able
s
(
Norma 4000/5000
)
80
TK
150
A
Thermocouple Module
S
hunt with
C
ables
S
ee
page
59
(Norma 4000/5000)
i
2000
FLEX
3
2 A
AC
C
urrent
C
lam
p
Planar Shun
t
S
e
e
page
6
0
(Norma 4000/5000
)
29
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Application tip
What’s included
Fl
u
k
e 1735 T
h
ree-P
h
ase Power Logger
General power quality logging
The Fluke 1735
p
rovides the im
p
ortant
d
ata
f
or electrical ener
gy
surve
y
s.
S
upplied PowerLog software enables detailed energy
ana
ly
s
i
s
.
Detailed power information enables load balancin
g.
F
or more in
f
ormation,
g
o to www.fluke.com/pq
P
ower Quality Analyzers
Ordering information
Included accessories Models
F
our flexible current probes (15 A
/
150 A
/
3000 A), Power Log software,
v
olta
g
e leads and clips, color localization set, P
C
interface cable,
i
nternational ac adapter (115 V/230 V, 50 Hz/60 Hz), soft carrying case,
users manual and multi-language manual CD.
F
LUKE-173
5
Th
ree-
Ph
ase
P
ower
L
ogge
r
U
SB cable, Power Log software CD, universal power cord adapters.
F
LUKE-VR171
0
V
oltage Quality Recorde
r
Fl
u
k
e VR1710
P
ower Quality Recorde
r
T
he Fluke 17
3
5 Three-Phase Power Logger
is
the ide
a
l ele
c
tri
c
i
a
n
o
r te
c
hni
c
i
a
n’
s
t
oo
l
f
or conducting energy studies and basic
p
ower quality logging. Set up the 17
3
5 in
s
econds, with the included
f
lexible current
p
robes and color display. The 17
3
5 logs
m
ost electrical power parameters and har
-
m
onics and captures voltage events
.
I
deal
f
or
f
ield o
p
eration:
C
ompact,
rugged instrument; easy to use, quickly
c
on
f
irm instrument setup with color
d
isplay o
f
wave
f
orms and trends
F
ull s
y
stem electrical measurement
c
apabilit
y
:Three phases and neutral
w
ith in
c
luded
fo
ur
f
lexible
c
urrent
p
robes
D
etect an
d
recor
d
vo
l
tage qua
li
ty pro
bl
em
s
Fast and easy recordin
g
o
f
volta
g
e trends, dropouts,
an
d
power qua
li
ty: easily pinpoint the root cause o
f
si
ng
l
e p
h
ase vo
l
tage pro
bl
em
s
E
xtreme
l
y easy to use: p
l
ugs
di
rect
l
y
i
nto t
h
e ma
i
ns
p
ower soc
k
et an
d
capture
d
ata
C
ontinuous recordin
g
of all values with no
g
aps:
s
ave test
i
ng t
i
me
b
y gett
i
ng t
h
e w
h
o
l
e p
i
cture w
i
t
h
one
i
nstrument t
h
at recor
d
s
b
ot
h
events an
d
vo
l
tage
C
lear
g
raphical summary of data and quick overview
of
key power quality parameters:
T
a
k
e t
h
e guesswor
k
o
ut of diagnosing voltage quality problem
s
Q
uickly see what happened and when
:
Mi
n
,
M
ax
,
and Average RMS values (1
/
4 cycle) with time stamp,
transient display
(
>100 s) with time stam
p
E
asily identi
f
y problems:
P
ower qua
li
ty or equ
i
pment
related Flicker recording to EN
6
1
000
-4-15, individual
h
armon
i
c an
d
THD
va
l
ues w
i
t
h
tren
d
s
S
tatistical analysis of sin
g
le phase volta
g
e events:
R
e
d
uces ana
l
ys
i
s t
i
me
b
y trac
ki
ng event quant
i
t
i
es an
d
m
agn
i
tu
d
e
s
Includes PowerLo
g
so
f
tware:
F
or qu
i
c
k
d
own
l
oa
d
,
ana
l
ys
i
s, an
d
automat
i
c report
i
ng
S
ave time: Generate power quality reports automat
i
-
ca
ll
y w
i
t
h
pre-set temp
l
ates
N
ew
:
T
rans
i
ent sens
i
t
i
v
i
ty sett
i
n
g
C
heck fluke.com support area for firmware and soft
-
w
are upgrades for Fluke power quality products.
F
luke VR1710
F
l
u
k
e
173
5
Prove the bene
f
it o
f
e
ff
icienc
y
improvements: Record power and
a
ssociated parameters
f
or up to 45 days. Monitor maximum power
demand over user-de
f
ined averaging periods
C
heck the power quality effects ener
g
y savin
g
devices: Me
as
ure
harmonics and distortion caused by loads and improve reliability
by capturing voltage dips and swells
f
rom load switching
E
as
y
P
C
connectivit
y
and operation
:
U
S
B interface for plug and
play operation; download, view graphs and automatically generate
r
eports with included Power Log so
f
tware
Reliable o
p
eration: Two-year warranty
30
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
What’s included
Online resources
Sample PDA screens
Features 1743/1744 1745 1750
M
easures common
p
ower
p
arameters:
V
,
A
,
W
,
VA
,
V
AR, PF, ener
gy
, flicker, volta
g
e events, and THD
M
easures volta
g
e and current harmoncs to the
50
t
h, un
b
a
l
ance, an
d
ma
ns s
gna
l
ng
T
rans
ent capture
PDA
suppor
t
GPS clock s
y
nchronzaton
UP
S
rde throu
g
h
3
s>
5
h
ours
5
m
n per
nterrupt
on,
60
mn total
D
mensons
1
7
0
mm x 1
2
5 mm x 55 mm
(
6.9 n x 5.1 n x 2.2 n
)
2
82 mm x 216 mm x 74 mm
(
11.5 n x
8
.
8
n x 3 n)
2
15 mm x
3
1
0
mm x
3
5 mm
(8
.5 n x 12.2 n x 3.5 n)
We
g
ht (approx.) 0.9 k
g
(2 lb)
1
.4 k
g
(3 lb)
6
.3 k
g
(14 lb)
T
he Fluke 1740 Series Three-Phase Power Qualit
y
Lo
gg
ers
are instruments for technicians who troubleshoot and ana
-
l
y
ze power distribution s
y
stems. The included PQ Lo
g
sof
t
-
w
are quickl
y
assesses the qualit
y
of power at the service
e
ntrance, su
b
stat
i
on, or at t
h
e
l
oa
d
, accor
di
n
g
to t
h
e
l
atest
EN
50
1
60
standard
.
Pl
u
g
an
d
p
l
ay
:
Setu
p
in minutes with automatic current
pro
b
e
d
etect
i
on an
d
power
i
n
g
I
n
s
ta
lls
i
n
sid
e t
h
e ca
bi
net: Compact, full
y
-insulated
housin
g
and accessories fit easil
y
in ti
g
ht spaces, next
to
li
ve
p
ower
D
eterm
i
ne
s
t
h
e root cau
s
e
:
Included PQ Lo
g
software
qu
i
c
kly
ana
ly
zes tren
d
s, creates stat
i
st
i
ca
l
summar
i
es,
an
d
g
enerates
d
eta
il
e
d
g
rap
h
s an
d
ta
bl
e
s
M
easure vo
l
ta
g
e w
i
t
h
prem
i
um accuracy
:
IEC
6
1
000-
4
-30 Class-A compliant volta
g
e accurac
y
(
0.1 %)
1
743
For more in
f
ormation,
g
o to www.fluke.com/p
q
P
ower Quality Analyzers
Fl
u
k
e 1750 T
h
ree-P
h
ase Power Recor
d
er
Never miss capturing a disturbance
F
luke 1740 Series Three-Phase
P
Q Loggers Memobox
P
ower qualit
y
that meets the standard
:
All
m
easurements comply with IE
C6
1
000
-4-
30
s
t
a
nd
a
rd
s
fo
r
co
rre
c
t ev
a
lu
a
ti
o
n
of
a
ll me
a
-
s
ured values including voltage, current, power,
h
armonics,
f
licker etc.
Q
uick and reliable configuration: PDA
w
ireless “
f
ront panel inter
f
ace” provides a
w
indow into what the instrument is recording,
e
nabling quick and reliable con
f
iguration even
i
n
a
wkw
a
rd te
s
t l
oca
ti
o
n
s
T
hreshold-
f
ree set u
p
:Apply thresholds a
f
ter
d
ata is collected with Fluke Power Analyze
S
oftware—no need to worry about missed
i
n
f
ormation due to incorrect setup
s
C
aptures everything
:
C
r
oss
-
c
h
a
nnel
a
nd
c
ur
-
rent triggering capture every measurement, on
e
very channel, every time
I
ntuitive P
C
software: Easily analyze data
and generate reports with automated EN5
0
1
60
reporting and compliance
Measure ever
y
parameter
:
Voltage and cu
r
-
rent on three phases, neutral, and ground
Specifications
Ordering information
Included accessories Models
Acquisition unit, PDA and char
g
er, power plu
g
adapters, four 4
00
A
current probes, five test leads and clips, SD memor
y
card, Fluke Power
View and Fluke Power Analyze software, power cord with international
plu
g
set, ethernet cable, color localization set, users manual and
C
D.
F
LUKE-175
0
Th
ree-
Ph
ase
P
ower
R
ecor
d
er
Four flexible probes 15
/
150
/
1500
/
3000 A with 2 m cable, PQ Log
software, RS-
232
interface cable and USB adapter, four dolphin clips, test
leads
f
or voltages and power supply, color localization kit, carrying bag,
test certificate with measurement values, users manual, multi-language
ma
nu
a
l
C
D.
FLUKE-17
45
P
ower Quality Logger – Memobox
FL
U
KE-174
4
P
ower Quality Logger – Memobox
FLUKE-174
3
P
ower Quality Logger – Memobox
I
n the U.
S
., these power qualit
y
recorders are sold exclusivel
y
throu
g
h power qualit
y
representatives. To request a
demonstration, or to order, call 1-888-257-9897 or email questions to fpqsupport@fluke.co
m
.
F
luke 1750
L
e
a
rn h
o
w t
o
d
o
wh
at
y
ou need to do, usin
g
F
luke power quality tools.
G
o to
:
www.fluke.com/pqtraining
ng
Pr
o
du
c
t dem
o
:
w
ww.fluke.com/175
0
O
nline training
:
w
ww.fluke.com/pqonlinetrainin
g
A
pplication notes
:
w
ww.fluke.com/pqappnotes
H
a
nd
s
-
o
n
s
emin
a
r
s
:
w
ww.fluke.com/pqtrn
g
seminar
s
Pr
o
du
c
t in
fo
rm
a
ti
o
n
:
w
ww.fluke.com/pqproducts
C
onfi
g
urations are
s
imple with wirin
g
di
a
g
rams to
g
u
id
e
y
ou
.
Vi
ew measurements
real-time with
w
irele
ss
PDA interf
ac
e
.
31
Check price and availability at
www.fluke.com/wtb
Process mA
Clamp Meter
ProcessMeter®
Test Tool Loop Calibrator
Pressure
Calibrator
Temperature
Calibrator
Precision
Multifunction
Process
Calibrator
Intrinsically
Safe
Calibrator
Documenting
Process
Calibrator
Models 773 789 715 719 724 726 725Ex 744
Measure
V dc 30 V 1000 V 25 V 30 V 30 V 30 V 300 V
V ac (true-rms) 1000 V 300 V
Resistance 40 M13200 14000 13200 111 k 1
A dc 20.99, 99.9 mA 30 mA, 1 A 24 mA 24 mA 24 mA 24 mA 24 mA 110 mA
A ac
Frequency 20 kHz 15 kHz 10 kHz 50 kHz
Pressure 1 psi, 30 psi,
100 psi and
300 psi2151
Temperature: RTDs 7 types 8 types 7 types 8 types
Temperature: TCs 12 types 13 types 12 types 13 types
Source/Simulate
V dc 10 V 20 V 10 V 20 V 10 V 15 V
Resistance 3200 14000 13200 111 k1
mA dc 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 22 mA
mA source; auto step,
auto ramp •••• •••
Frequency 15 kHz 10 kHz 50 kHz
Temperature: RTDs 7 types 8 types 7 types 8 types
Temperature: TCs 12 types 13 types 12 types 13 types
Record
Min/Max ••
Hold •• •
As found/As left results
Log data
Upload data to PC
Remote operation • •
Features
24 V loop supply ••••••
12 V
Non-contact mA
measurement
HART communication
Integrated hand pressure
pump Electric
Intrinsically safe (ATEX)
Warranty Three-year Three-year Three-year One-year Three-year Three-year Three-year Three-year
NIST traceable
certification ••••••
Accessories3A/B A/B C A/B A/B
Pressure enabled4• •••
See page 32 33 34 38 37 36 39 35
1Fluke 700 Pressure Modules required.
2Either the internal sensor or a Fluke 700 Pressure Module may be used.
3Accessories: A. Compatible with LockPak B. Compatible with TPAK C. Accepts hanging straps from TPAK D. Optional accessories.
4Fluke Process Calibrators in this guide displaying the Pressure Enabled symbol display readings from the 700 Series Pressure Modules.
5Fluke 700PEx Pressure Module required.
Pick the right process tool for you
Process Tools Selection Guide
For more information, go to www.fluke.com/processtools Process Calibration Tools
32
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fl
u
k
e
.
co
m
/
771
P
roce
ss
C
alibration Tool
s
Resources
Application tip
Fl
u
k
e 771, 772 an
d
773
m
A Process Clamp Meter
s
General specifications 771 772 773
B
atter
y
2
1.5 V
,
Alkaline
,
IE
C
LR
6
4
W
orking hours
20
hours t
y
pical 1
2
hours
@
1
2
mA source into 5
00
ohms
Size
(
HxWxL
)
5
9 mm x 3
8
mm x 212 mm
(
2.32 in x 1.5 in x 8.35 in
)
41.3 mm x 76 mm x 248 mm
(
1.625 in x 3 in x 9.75 in
)
W
ei
g
ht 260
g
(9.1 oz)
4
15
g
(14 oz)
Operatin
g
temperature -10
°
C to 50 ºC
IP
rat
i
n
g
I
P 4
0
W
arranty
Th
ree-
y
ear, one-
y
ear on m
A
c
l
amp assem
bly
an
d
ca
bl
e
Use the Fluke 771
,
772
and 773 to
:
M
easure 4-
20
mA signals with
-
o
ut
”b
rea
ki
ng t
h
e
l
oop,
save
time and money troubleshoo
t
-
i
ng 4-
20
mA signal
s
U
s
e the Fl
u
ke 77
2
and
77
3
t
o:
S
ource 4-20 mA si
g
nals for
testin
g
control s
y
stem I/O or
I/
P
s
S
imulate 4-20 mA si
g
nals for
testin
g
control s
y
stem I/O
M
easure 4-20 mA si
g
nals with
i
n-circuit measuremen
t
Power a transmitter with the
24 V loop power suppl
y
A
utomaticall
y
ramp and step
c
han
g
e the 4-20 mA output for
remote testin
g
mA
measure
w/jaw
mA
measure
In circuit mA source mA sim
Loop
power
24 V
DCV
source
0-10 V
DCV
measure
0-30 V
Scaled mA
output to
mA input mA in/out
771
772
7
7
3
Function Resolution and range Accuracy Notes
7
71
,
77
2,
77
3
m
A me
as
urement
0
to
20
.
99
mA
0
.
2
% + 5 count
s
M
easure
d
by
c
l
amp
21.
0
mA to 1
00
.
0
mA
1
%
+
5
counts
77
2
an
d
77
3
mA
me
as
urement
0
to 24.
00
m
A
0
.2 % + 2 counts
M
easure
d
i
n ser
i
es w
i
t
h
test
j
ac
k
s
7
72 and 773
mA
sourc
e
0
to
2
4.
00
mA
0
.
2
% +
2
counts Maximum mA drive:
2
4 mA into
1
,
000 ohm
s
772 and 77
3
mA simulate
0
to
2
4.
00
m
A
0
.
2
% +
2
counts
M
aximum volta
g
e 5
0
V dc
77
3
V
olta
g
e source
0
to 1
0
.
00
V dc
0
.
2
% +
2
count
s
2
mA maximum drive current
7
7
3
Volta
g
e measure
0
to
30
.
00
V d
c
0
.
2
% +
2
counts
Use the Fluke 773 to:
D
C
voltage measurement to verify
2
4 V power supplies
o
r voltage I
/
O signal
s
S
ource dc voltage to test voltage input device
s
S
caled mA output signal enables a logging DMM
(
2
8
9) to
record 4-
20
mA signal without breaking the loop
m
A in
/
out: simultaneously source a mA signal while
m
easur
i
ng a m
A
s
i
gna
l
w
i
t
h
t
h
e c
l
amp
N10140
Specifications
Features
Ordering information
Included accessories Models
S
oft carrying case, users
ma
nu
al.
FLUKE
-
771
Milliam
p
Process Clam
p
Meter
T
est
l
ea
d
s, a
llig
ator c
li
ps an
d
han
g
in
g
strap, so
f
t carr
y
in
g
case, users manual.
F
L
U
KE-77
2
M
illiamp Process
C
lamp Mete
r
F
LUKE-77
3
M
illiamp Process
C
lamp Mete
r
With the 77X family of millamp clamp
meters you can measure 4 to
20
mA
I
/
O signals without “breaking the
l
oop. Once a bad signal is found the
sourcing functions of the 77
2
and 77
3
c
an be used to further troubleshoot
th
e
l
oop.
More info online at
www.fluke.com/
p
rocesstool
s
C
heck out the 77
3
video a
t
w
ww.fluke.com
/
773
Fluke
771
Fluke
772
Fluke
773
R
OI calculator
:
w
ww.fluke.com
/
77X_ROI
A
ll the in
f
ormation you need at
w
ww.fluke.com
/
processsolutions
33
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Resources
F
or more in
f
ormation,
g
o to www.fluke.com/processmeters
P
roce
ss
C
alibration Tool
s
F
l
u
k
e 789 an
d
787
P
rocess
M
eter
Test Too
l
s
F
luke 789 ProcessMete
r
W
ith the Fluke 7
8
9 ProcessMeter, process technicians
an
d
o a
l
ot more w
hil
e carry
i
ng a
l
ot
l
ess.
2
4 V loop power suppl
y
HART
mo
d
e sett
i
ng w
i
t
h
l
oop power
(
adds 250 ohm resistor
)
D
ou
bl
e-s
i
ze
d
,
d
ua
l
di
sp
l
a
y
20
mA drive into 1
200
ohm
s
B
ac
kli
g
h
t w
i
t
h
two
b
r
i
g
h
tness sett
i
ngs
0
% to 1
00
% mA Span
C
heck buttons to toggle
b
etween 4-
20
mA
I
nfrared I
/
O serial port compatible with
Fl
u
k
e
Vi
e
w
®
Forms Softwar
e
Improved battery power with four AA batteries
P
lus all the proven 7
8
7 features
F
luke 7
8
7 ProcessMeter
S
imult
a
ne
o
u
s
mA
a
nd %
o
f
s
cale readout on mA outpu
t
2
5 % Manual Step plus Auto
S
tep and Auto Ramp on mA
o
u
t
pu
t
M
in
/
Max
/
Average
/
Hold
/
R
el
a
tive m
o
de
s
E
xternally accessible battery
f
or easy change
s
(
Fluke 7
8
9 onl
y
)
More info online at
www.fluke.com/
p
rocesstool
s
C
heck out our latest videos at
w
ww.fluke.com
/
ptoolsvideos
Increase
y
our skills a
t
w
ww/fluke.com/processtrainin
g
True
RMS
600V
CAT IV
Designed and
Conforms to
IEC 1010-1
80
T-1
50U
PV3
50
Universal
P
ressure Vacuum
T
em
p
erature
P
ro
b
e
Mod
u
l
e
S
ee pa
g
e 5
9
S
ee
p
a
ge
63
TPAK
TL22
0
M
a
g
net
i
c
S
ureGrip Industrial
M
eter Han
g
er
T
est Lead Se
t
S
ee
page
62
S
ee
page
55
Fluke
787
Specifications
Ordering information
Included accessories Models
Test leads, alligator clips, 4 AA alkaline batteries (installed), quick refer
-
r
e
nce guide, users manual, multi-language manual
C
D.
F
LUKE-7
8
9
P
rocessMete
r
T
est leads, alligator clips, holster with test lead storage, one
9
V alkaline
batter
y
(
installed), quick reference
g
uide, users manual, multi-lan
g
ua
g
e
ma
nu
a
l
C
D.
F
LUKE-78
7
P
rocessMete
r
Measurement function Best accuracy range and resolution (% of reading + LSD)
V
d
c
4
00
.
0
mV
,
4.
000
V
,
4
0
.
00
V
,
4
00
.
0
V
,
1
000
V
0
.1 % + 1
V
dc
(
true-rms) 4
00
.
0
mV
,
4.
000
V
,
4
0
.
00
V
,
4
00
.
0
V
,
1
000
V
0
.7 % +
2
m
A dc
30
.
000
m
A
.
0
5 % +
2
A
dc 1.000 A (0.440 A continuous)
0
.
2
% +
2
A
ac 1.000 A (0.440 A continuous)
1
% +
2
R
es
i
stance 4
00
.
0
1
,
4.
000
k
,
4
0
.
00
k
,
4
00
.
0
k
,
4.
0
M
,
4
0
M
0
.
2
% + 1
Frequenc
y
(0.5 Hz to 20 kHz) 1
99
.
99
Hz
,
1
999
.
9
Hz
,
1
9
.
999
kHz .
00
5 % + 1
D
iode tes
t
7
8
9: 2.000 V
(
shows diode volta
g
e drop) 7
8
7: 2.400 V
(
shows diode voltage drop) 2
%
+ 1 2
%
+ 1
C
ontinuit
y
Beeps for resistance < approx. 1
00
ohms
Output function Range and resolution Drive capability Accuracy
(% of span)
DC current output (internal
battery operation)
0
.
000
mA to
20
.
000
mA or 4.
000
mA to
20
.
000
mA
(
selectable at power-up) Over-range to 24.000 mA
7
89: 24 V compliance
or
,
1
,200
ohms
,
@
20 mA 7
8
7: 12 V
com
pli
ance or,
500
ohms
,
@
20
mA
.05
%
DC current simulate
(
external
2
4 V loop suppl
y
, up to 48 V on
7
8
9 only)
0
.
000
mA to
20
.
000
mA or 4.
000
mA to
20
.
000
mA
,
(
selectable at power-up) Over-range to 24.000 mA
1
000 ohms, @ 20 mA
.05
%
2
4 V loop suppl
y
78
9: Minimum 24 V 7
8
7: Not available 250 ohms
@
20 mA >
24 V
C
urrent ad
j
ustment modes Manual: Coarse, Fine, 25 % and 100 % step (100 % step 789 onl
y
)
Automatic: slow ram
p
, fast ram
p
, 25 % ste
p
Temperature range of 18 °C to 28 °C, for one year after calibration.
M
ax
i
mum vo
l
tage app
li
e
d
b
etween any
j
ac
k
an
d
eart
h
groun
d
:1
000
V rms. Stora
g
e temperature
:
-40 °C to 60 °C.
Operatin
g
temperature
:
-20
°
C to 55
°
C. Relative humidit
y:
95 % up to 30
°
C; 75 % up to 40
°
C; 45 % up to 50
°
C; 35 % up to 55
°
C
.
S
afet
y
:Designed in accordance with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Over-voltage CAT III
.
S
ize (HxWxL)
/
wei
g
ht (787 with holster): 52 mm x 98 mm x 201 mm (2.06 in x 3.86 in x 7.93 in)
/
638 g (1.4 lb)
.
S
ize (HxWxL)
/
wei
g
ht (789)
:
50 mm x 100 mm x 203 mm (1.97 in x 3.94 in x 8.00 in)
/
600
g
(1.3 lb).
Warrant
y
:Three-
y
ear
.
A
ll the information
y
ou need at
w
ww.fluke.com/
p
rocesssolutions
34
Specialty models
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Resources
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/loo
p
k
e 715 Volt
/
mA Calibrato
r
u
rce voltage to
200
mV or
20
V
a
sure loop current
(
0 to 20 mA, 4 to 20 mA) signals
t
h
0
.
0
1 % accuracy and 1 µA resolutio
n
a
sure voltage output process signals from PL
C
s,
n
sm
i
tters
u
rce or simulate 4-
20
mA loop current
V loop supply with simultaneous current
a
suremen
t
m
p and Step Ramp output functions
k
e 7
0
7 and 7
05
n
ovative output adjustment dial on 7
0
7 provides
A and 1
00
µA resolution and one-hand operation
r
ge display and simple inter
f
ace
f
or ease o
f
use
m
ultaneous mA and % readout for quick, easy
e
rpretation o
f
readings
A
accuracy of
0
.
0
15 % on the Fluke
7
and
0
.
02
% on the 7
05
R
T™ mode on 7
0
7 connects
2
5
0
m
re
s
i
s
t
o
r in
s
erie
s
with
2
4 V
p
f
or compatibility with HART
m
muni
ca
t
o
r
s
s
h button
2
5 % steps for fast, easy
e
arity check
s
p
an
C
heck” for fast confirmation o
f
o
and span
F
luke 715, 707 and 705 Loo
p
Calibrators
Complete family of volt/mA calibrators
Will over-ran
g
e to
2
4 mA
.
P
roce
ss
C
alibration Tool
s
Fl
u
k
e
7
0
7 Ex
Intrinsicall
y
Safe
Loop Calibrato
r
See
page
39
for
more
inf
o
rmati
o
n.
Selectable slow and fast linear step ramp provide
ramping outputs for valve slewing, remote testing and
l
oop functional tests
2
4 V internal loop supply, so you can power and read a
transm
i
tter at t
h
e same t
i
me w
i
t
h
out carry
i
ng a
DMM
0
-
20
mA or 4-
20
mA default start up modes
More in
f
o online at
www.fluke.com/
p
rocesstool
s
C
he
c
k
o
ut
o
ur l
a
te
s
t vide
os
a
t
w
ww.fluke.com
/
ptoolsvideos
C550
P
V3
50
Tool Ba
g
P
ressure Vacuum
S
ee
page
5
4
Mo
dul
e
S
ee pa
g
e
6
3
T
L28
A
TL22
0
H
eav
y
D
ut
y
S
ure
G
rip Industrial
Test Lead Set Test Lead Se
t
S
e
e
page
55
Specifications
Ordering information
Included accessories Models
T
est leads, alligator clips, holster with test lead storage, NIST-traceable
c
alibration report and data, single
9
V alkaline battery, instruction sheet
(
14 lan
g
ua
g
es)
.
FLUKE
-
715
Volt
/
mA Calibrator
F
LUKE-7
0
7 Loop
C
alibrator
F
LUKE-7
0
7 Ex Intrinsicall
y
Safe Loop Calibrator
F
LUKE-7
05
Loo
p
C
alibrator
Functions Fluke 705 and 707 Fluke 715
V
o
l
ta
g
e measurement
R
ange
0
V to 2
8
V
0
mV to 2
00
m
V
0
V to 2
5
V
R
e
sol
ut
ion
1mV
10
µV
1mV
A
ccuracy 705: 0.025 % Rdg + 1 LSD 707,
7
0
7Ex:
0
.
0
15 % Rd
g
+
2
LSD
0
.
0
1 % Rd
g
+
2
LS
D
C
urrent measuremen
t
R
ange
0
mA to 24 mA
0
mA to 24 m
A
R
e
sol
ut
io
n
0
.
00
1 mA
0
.
00
1 m
A
A
ccurac
y
705: 0.02 % Rdg + 2 LSD 707,
70
7Ex:
0
.
0
15 % Rd
g
+
2
LSD
0
.
0
1 % +
2
LS
D
C
urrent sourcing
R
an
ge
0
mA to
20
mA or 4 mA to
20
m
A
1
0
mA to 2
0
mA or 4 mA to 2
0
mA
A
ccuracy 705: 0.025 % Rdg + 2 LSD 707,
70
7Ex:
0
.
0
15 % Rd
g
+
2
LSD
0
.
0
1 % Rd
g
+
2
LSD
D
rive capabilit
y
7
05
: 1
000
1
@
2
4 mA 7
0
7: 1
200
1
@
24 mA 7
0
7Ex: 7
00
1
@
20 m
A
1000
1
@
24 mA
L
oop power w
hil
e measur
i
n
g
m
A
24 V
24 V
V
o
l
ta
g
e sourc
i
n
g
0
mV to
200
mV or
0
V to
20
V
D
ispla
y
current and % of span
Y
e
s
mA
o
r
%
A
uto step, auto ramp
Y
e
s
Y
e
s
S
p
an Check
Y
e
s
Y
e
s
Battery lif
e
18
hours typical, at 12 mA 1
8
hours typical, at 12 m
A
Warranty
T
hree-yea
r
Fluke
707
A
ll the in
f
ormation you need at
w
ww.fluke.com
/
processsolutions
35
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended software
Resources
Recommended accessories
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/
740
F
luke 741B, 743B and 744 Calibrator
s
Calibrate/troubleshoot process control instrumentation
Functions Measure Sourcing
DC voltag
e
0.025 % reading +
0
.
005
% full scale
0
.01 % out
p
ut +
0
.
005
% full scal
e
D
C
c
urrent 0.01 % reading +
0
.
0
15 % full scal
e
0.01 % out
p
ut +
0
.
0
15 % full scale
R
e
sis
t
a
n
c
e
0
.
0
5 % readin
g
+ 5
0
m
0
.
0
1 % output + 4
0
m
F
requenc
y
0
.
0
5 %
0
.
0
1
%
Th
ermocoup
l
es
0
.3 °C
0
.2 °
C
RTDs
0
.3 °C
0
.1 °
C
P
re
ss
ure To 0.25 % of full scale,
p
er
p
ressure
m
odule specifications
a
librate temperature, pressure, voltage, current,
s
istance and
f
requency instruments
u
ilt-in procedures
f
or transmitters, square root
a
nsmitters, pressure and temperature switche
s
m
ultaneously measure and source
u
tomatically capture calibration results
o
cument procedures and results to meet I
SO
000
, EPA, FDA, OSHA, and other government
q
uirements
e
asure/simulate 13 types of thermocouples and
g
ht RTD
s
o
re up to
8
,000 readings in data logging mode
4
3B and 744 only)
o
tected against dirt, dust and moisture; una
f
-
c
ted by vibratio
n
c
ludes a PC interface
(
743B and 744 only)
p
erate in English, French,
G
erman, Italian and
p
anish
n
e- and two-year calibration cycles and a
r
ee-year warranty
(
one-year for pressure
o
dules
)
4
: Get HART-abilit
y
F
luke 744 o
ff
ers all o
f
the ca
p
abilities o
f
the
B
, plus the abilit
y
to calibrate, maintain, and
b
leshoot HART instrumentation. Inte
g
rated
HART communication functions permit you to moni
-
tor
,
control
,
and calibrate HART instrumentation. It
h
andles
f
ast
p
ulsed instruments such as RTD tran
s
-
m
itters and PLCs, with
p
ulses as short as 1 ms
.
S
ee www.fluke.com
/
744upgrade for the latest
l
ist of HART instruments
.
S
ummar
y
specifications: best case, mid-ran
g
e,
one
y
ear.
B
atter
y
life
:
Ty
p
i
ca
lly
over e
igh
t
h
our
s
I
nterna
l
b
atter
y
pac
k
:NiMH 3
500
mAh
B
atter
y
rep
l
acement
:
Vi
a sna
p
-s
h
ut
d
oor
wi
t
h
out open
i
n
g
ca
lib
rator; no too
l
s requ
i
re
d
W
e
igh
t: 1.4 k
g
(3 lb, 1 oz)
S
ize
(
HxWxD
):
23
6
mm x 13
0
mm x
6
1 mm
(
9.3 in x 5.1 in x 2.4 in
)
P
roce
ss
C
alibration Tool
s
More in
f
o online at
www.fluke.com/
p
rocesstool
s
A
ll the in
f
ormation you need at
w
ww.fluke.com
/
processsolutions
700PTP-
1
C78
9
P
neum
a
t
ic
M
eter
a
n
d
T
est
P
ump Accessor
y
C
ase
See
page
59
S
e
e
page
54
700P
xx
700P
8
0PK-2
5
P
re
ss
ure
Mod
u
l
e
s
S
ure
G
rip Piercin
g
S
ee pa
g
e
38
T
emperature
P
ro
be
S
ee
page
5
8
741B
:
A
comp
l
ete
d
ocument
i
ng ca
lib
rato
r
T
he 741B is the economical choice for plants that don’t use
P
C
s or that require traditional paper forms. It has storage
c
apacity for a days calibration and measurement data.
Wh
en you
re
b
ac
k
at t
h
e s
h
op, reca
ll
t
h
e
d
ata on-screen to
fill out calibration forms
.
743B: More memory, plus a PC interface
and data lo
gg
in
g
T
he 74
3
B has all the ca
p
abilities of the 741B
p
lus a P
C
i
nter
f
ace that lets you load procedures, lists, and instru
c
-
tions created with so
f
tware—or unload data
f
or printing,
archiving, and analysis. With its expanded memory, the
74
3
B can hold a full week of calibrations and
p
rocedures.
I
nstrumentat
i
on
m
ana
g
ement so
f
tware
The Fluke 74
3
B and 744 are compat
-
i
ble with Fluke 700SW DPC/TRACK
sof
tw
a
re
a
nd with
sof
tw
a
re
f
r
o
m
C
ornerstone, Emerson, Honeywell,
O
n Time
S
upport, Prime Technolo
-
g
ies, Yokogowa, Intools, Meridium
a
nd Be
a
mex.
F
or more in
f
ormation, visit
w
ww.fluke.com/software
Specifications
Ordering information
Included accessories Models
Industrial test leads
(
2 sets), test cli
p
s
(
2 sets), test
p
robes, NiMH
batter
y
pack, batter
y
char
g
er, serial port cable, DPC
/
TRACK
s
ample version with free P
C
communication utilit
y
software, HART
communications cable, HART user’s manual, NI
S
T traceable calibration
certificate and data, instruction manual
.
FL
U
KE-74
4
D
ocumenting Process Calibrator
I
ndustrial test leads (2 sets), test clips (2 sets), test probes, battery
pack, batter
y
char
g
er, serial port cable (743B onl
y
), DPC
/
TRACK sample
version with free PC communication utilit
y
software
(
743B onl
y
), NIST
traceable calibration certificate and data, instruction manual.
F
LUKE-74
3B
Documenting Process Calibrator
F
L
U
KE-741B Documenting Process Calibrator
F
LUKE-7
00S
DPC
/
Track Softwar
e
Pressure
Enabled
Fluke 743B
w
ww.fluke.com
/
ptoolsvideos
36
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/
726
F
luke 726 and 725 Multifunction
P
rocess Calibrators
luke 726 Precision Multifunction
P
rocess
C
alibrato
r
h
e Fluke 7
26
measures and sources almost all pro
-
e
ss parameters an
d
can ca
lib
rate a
l
most anyt
hi
ng.
n
terpret results without the help o
f
a calculator and
t
ore measurement data
f
or later analysis.
Precise measurement and calibration source per
f
or
-
m
ance, accuracies of
0
.
0
1
%
T
ransmitter error% calculation, interpret calibration
re
s
ult
s
with
o
ut
a
ca
l
c
ul
a
t
or
M
emory storage
f
or up to eight calibration results,
return
s
t
o
red
ca
libr
a
ti
o
n d
a
t
a
f
r
o
m the
f
ield
fo
r l
a
ter
analysi
s
F
requency totalizer and
f
requency pulse train source
m
ode
f
or enhanced
f
lowmeter testin
g
HART mode inserts
2
5
0
ohm resistor in mA
m
easure and source
f
or compatibility with HART
i
n
s
trument
a
ti
o
n
Integrated pressure switch test allows you to capture
the set, reset and deadband o
f
a switch
C
ustom RTD curves, add calibration constants for
c
erti
f
ied RTD probes
f
or temperature measuremen
t
Voltage input protection design
f
or improved
re
li
a
bili
t
y
M
easure and sourc
e
Functions Range or type Resolution Accuracy Notes
V
o
l
ta
g
e
0
to 1
00
mV
0
to 10 V (source)
0 to 20 V
(
source
)
0
to 30 V
(
measure
)
0
.
0
1 mV
0
.
0
1 V
0
.
0
1 V
0
.
0
1 V
0
.
0
1
%
,
0
.
02
%
Rdg + 2 LS
D
M
ax
l
oa
d
,
1
m
A
mA
0
to 2
4
0
.
00
1 m
A
0
.
0
1
%
,
0
.
02
%
Rd
g
+
2
LSD
M
ax load, 1000
1
mV (TC
t
erminals
)
-1
0
.
00
mV to
+7
5
.
00
mV
.
0
1 mV
0
.
0
1
%
,
0
.
02
%
of range + 1 L
SD
O
hms 1
5
1 to 3
,
200 1
5
1
to 4,
000
1
0
.
0
1
1
t
o
0
.1
1
0
.1
0
1 to 1.
0
1
0
.
0
15 %
H
z -
C
PM 2.0 to 1,000 CPM
1
to 1
000
Hz
1
.
0
to 1
0
.
0
kHz
1
0.0 to 15.0 kHz
0
.1 CPM
1Hz
0
.1 k Hz
0
.1 kHz
±
0
.
05
%
±
0
.
0
5 %
±
0
.
2
5 %
± 0.05 %
S
ource;
5
V
p-p
1 V to 20 V
p
-
p
sq
u
a
r
e
w
a
v
e
,
-
0
.1 V offse
t
L
oop supp
ly
24 V d
c
N/A
10
%
T
/C
J
,
K
,
T
,
E
,
L
,
N
,
U
,
XK
0.1 °C, 0.1 °F to
0
.7 °C
t
o
0.2
°
C
T
/C
B, R,
S
, B
P
1
°C, 1 °F t
o
1.7 °
C
to 1.2
°
C
RTD
sCu
(
10
)
, Ni120 (672)
Pt 100
,
200
,
500
,
1
000
(
3
8
5
)
Pt 100
(
3916
)
,
Pt 100 (3926
)
0
.01
°
C,
0
.
0
1 °
F
0.1 °C, 0.1 °F
to 0.15
°
C
to 0.2 °
C
Unique 72
6
s
p
ecifications are bolded
.
Simultaneous function capability Channel A Channel B
2
4.
000
mA d
c
M
M or
S
2
4.
000
mA dc with
2
4 V loop suppl
y
M
1
00
.
00
mV dc M or
S
30
.
000
V dc measure
M
20
.
000
V dc measure
;
1
0
.
000
V dc source
;
20
.
000
V dc sourc
e
M
o
r
S
15 to 3200 Ohms
(
725
)
; 5 to 4000 Ohms
(
726
)
M
o
r
S
T
hermocouple J, K, T, E, R,
S
, B, M, L, U, N, XK, BP M
o
r
S
RTD Cu 10, Ni120; Pt100
(
392
)
; Pt100
(
JIS
)
; Pt100, 200, 500, 1000
(
385
)
, XK and BP M
o
r
S
P
ressure (requires Fluke 700PXX Modules)
M
M
u
s
ed
as
S
F
requency; 10 kHz;
(
15 KHz 726
)
M
o
r
S
M
= Measure, S = Source
/
Simulate
General specifications
S
torage temperature:
-
20
°
C to 71
°
C
O
perating temperature
:
-
10
°
C to 55
°C
R
e
l
at
i
ve
h
um
idi
ty
:
9
0 % (10
°
C to 30
°
C);
75 % (30
°
C to 40
°
C);
45 %
(
40
°
C to 50
°
C
)
;
35 %
(
50
°
C to 55
°
C
)
S
h
o
ck
:
1
meter
d
ro
p
tes
t
S
afet
y
:
CS
A
C
22.2
No. 1
0
1
0
.1:199
2
EM
C
:EN
5008
2-1:1992 and
EN
550
22:1994 Class
B
Size
(
HxWxD
):
2
00
mm x
9
6 mm x 47 mm
(
7.9 in x
3.8 in x 1.9 in
)
W
e
igh
t: 650
g
(23 oz)
B
atter
y
:
Fo
ur
AA
alkali
ne
ba
tter
i
e
s
B
atter
y
life: 25 hours t
y
pica
l
W
arrant
y:
Th
ree-
y
ear
s
Fluke 725 Multifunction
Process
C
alibrato
r
M
easure vo
l
ts, m
A
,
RTD
s, t
h
erm
o
-
c
ouples,
f
requency
a
n
d
oh
m
s
t
o
t
e
s
t
s
en
so
r
s
a
n
d
t
r
a
n
s
m
i
tter
s
S
ource
/
simulate
vo
l
ts, m
A
, t
h
e
r
-
mocoup
l
es,
RTD
s,
f
requency, ohms
a
n
d
pressure to ca
l
-
ib
r
a
te tr
a
n
s
m
i
tter
s
M
easure
/
source
p
ressure us
i
ng any
o
f
29
Fluke 7
00
Pxx
P
re
ss
ure
Mod
u
l
e
s
So
ur
c
e mA with
s
imult
a
ne
o
u
s
p
ressure measurement to con
d
uct
valve and I
/
P test
s
S
upport flow meter testing with
f
requency and counts per minute
(
CPM
)
function
s
Per
f
orm
f
ast linearity tests with
a
uto step and auto ramp
f
eature
s
Specifications
Included accessories Models
T
est leads, test cli
p
s, one
p
air o
f
stackable test
leads, product overview manual, users manual in
1
4 lan
g
ua
g
es on CD.
FLUKE-7
26
Pre
c
i
s
i
o
n Multifun
c
ti
o
n Pr
oc
e
ss
Ca
libr
a
t
o
r
FLUKE-72
6
E
x
I
ntrinsicall
y
Safe Precision Multifunction Process Calibrator
FLUKE-72
5
Multifun
c
ti
o
n Pr
oc
e
ss
Ca
libr
a
t
o
r
Ordering information
Pressure
Enabled
700
Pxx
C
12
5
P
re
ss
ure
Mod
u
l
e
s
Soft
C
arr
y
in
g
C
as
e
S
ee
page
3
8
Recommended accessories
TPAK
80
PK-
2
7
M
agnetic Indu
s
tri
a
l
S
urf
ac
e
M
eter
H
ange
r
T
emperature
P
ro
b
e
S
e
e
p
a
g
e
62
S
e
e
p
a
ge
58
Take the 72
5
virtual demo tour at
w
ww.fluke.com
/
725demo
I
ntrinsicall
y
safe version available
(see page 39)
Process
C
alibration Tool
s
37
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/tempcal
Recommended accessories
Resources
Specialty model
Models Functions Range Resolution Accuracy Notes
Fluke 712
M
easure
/
simulate RTD
-
2
00
°C to
800
°C
(
Pt 100-385
)
0.1
°
C
,
0.1
°
F0.2
°
C
,
0.4
°
F
(
Pt 100-3
8
5
)
Pt; 100 200 500
1
000 (385); Pt 100
(
392); Pt 100
(
392) JIS;
N
i 120
(
672
)
Measure
/
simulate
r
e
sis
t
a
n
ce
5
1
to 4
000
1
0
.1
1
0
.
02
5 %
Fl
u
k
e
71
4
M
easure
/
simulate
th
ermocoup
l
e
-200
°
C to 1800
°
C
,
depending on type
(
K, -200 °C to
1
370
°
C)
0
.1 °C or °F
(
1 °C or °F; BRS
)
0
.5 °C, 0.8 °
F
(Type K)
9
T
C
t
y
pes
;
J
K
T
E
R
S B per NIST 175 and
ITS-90 L U
p
er DIN
4
371
0
and PTS-
68
Measure
/
simulate mV -1
0
mV to 7
5
mV
0
.
0
1 m
V
0
.015 % +10
µV
Fl
u
k
e 712, 714 an
d
724
Temperature Calibrator
s
M
ax
i
mum vo
l
ta
g
e:
30
V.
N
on-operat
i
n
g
temperature
:
-40
°
C to 60
°
C.
O
peratin
g
temperature: -10
°
C to 55
°
C
.
Relative humidit
y:
95 % (10
°
C to 30
°
C); 75 % (30
°
C to 40
°
C); 45 % (40
°
C to 50
°
C); 35 % (50
°
C to 55
°
C).
O
perating altitude: 3,000 m max. Shock
:
1
m
d
ro
p
test.
Vib
rat
i
on
:
Random, 2 g, 5-500 Hz.
Safety
:
C
SA
C22
.
2
No. 1
0
1
0
.1:1
992
. EM
C
:EN50082-1:1992 and EN55022:1994 Class B
.
Size/weight (HxWxD) (712-717): 187 mm x 87 mm x 32 mm (7.35 in x 3.41 in x 1.25 in) 330
g
(12 oz)
.
Size/weight (HxWxD) (712-717 with holster)
:
201 mm x 9
8
mm x 52 mm
(
7.93 in x 3.
8
6 in x 2.06 in) 600 g
(
21 oz).
Size
/
wei
g
ht (HxWxD) (718)
:
210 mm x 83 mm x 62 mm (8.25 in x 3.27 in x 2.44 in) 737 g (26 oz)
.
Size
/
wei
g
ht (HxWxD) (718 with holster)
:
216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in) 992
g
(35 oz)
.
P
ower
:
9 V batter
y
ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 .
Battery life: 4 to 20 hours, typical, depending on functions used.
W
arranty
:
Three-
y
ear (one-
y
ear on pressure pump in Fluke 718)
.
Specifications
T
he Fluke 71
0
Series temperature calibrators deliver
o
utstanding per
f
ormance, durability and reliability.
A
nd with a push-button inter
f
ace, similar to the
m
ultifunction Fluke 74
0
Series Documenting Process
C
alibrators, the 71
0
Series are easy to use. Each
c
alibrator is EMI tolerant, dust- and splash-resistant,
and
f
eatures a removable battery door
f
or quick battery
c
hanges.
Fluke 714 Thermocouple
C
alibrato
r
M
easure tem
p
erature from TC
p
robe
s
S
imulate TC out
p
u
t
Operable with nine t
y
pes of thermocouple
s
Ca
libr
a
te line
a
r T
C
tr
a
n
s
mitter with mV
so
ur
c
e
f
un
c
ti
on
S
ele
c
t
a
ble °F
o
r °
C
25 % steppin
g
, auto-step and auto-ram
p
A
vailable as accessories: Fluke 7
00
TC1 and TC2
T
hermocouple Mini-plu
g
Kits
R
am
p
and Ste
p
Ram
p
out
p
ut functions
Fluke 712 RTD Calibrator
Com
p
atible with
p
ulsed current
transm
i
tters
M
easure tem
p
erature from an
RTD
p
ro
b
e
S
imulate RTD out
p
u
t
Operates with seven t
y
pes of RTD
M
easure a
ddi
t
i
ona
l
RTD
s us
i
n
g
o
hms measurement function
S
imulate additional RTDs usin
g
o
hms source function
°
F or °C selectable
25 % steppin
g
, auto-step and
auto-ram
p
R
am
p
and Ste
p
Ram
p
out
p
ut
functions
Fluke 724 Tem
p
erature
C
alibrator
S
ource/measure
T
C
s, RTDs, volts
a
nd
o
hm
s
M
e
as
ure mA
while supplying
l
oop powe
r
2
5 % and 1
00
%
stepping, auto-
step and auto
r
a
m
p
Included accessories Models
T
est leads, test clips, one pair of stackable test leads, product overview
m
anual, users manual in 14 languages on
C
D.
F
LUKE-72
4
Temperature Calibrato
r
T
est leads, alligator clips
(
excluding model 714), holster with test lead
s
tora
g
e, sin
g
le 9 V alkaline batter
y
and instruction sheet
(
14 lan
g
ua
g
es).
F
LUKE-71
4
Themocouple
C
alibrator
F
LUKE-71
2
R
TD Calibrator
Ordering information
T
L75 (712
/
724
)
TL220 (712
/
724
)
H
ard Poin
t
SureGri
p
Industria
l
T
e
s
t Le
a
d
S
e
t
T
e
s
t Le
a
d
S
e
t
S
ee
p
a
ge
57
S
ee
p
a
ge
55
TPA
K
A
C220
M
agnetic Meter Hange
r
S
ureGrip Alligator Clips
S
ee
p
a
ge
6
2
S
ee pa
g
e
57
80PK-24
(
714/724
)
80PK-3A
(
712/724
)
S
ureGrip Air Surface Probe
Tem
p
erature Prob
e
S
e
e
page
5
8
S
e
e
page
5
8
C
101
(
724
)
C25 (712/714)
Meter Hard Case
L
arge Soft Case
S
e
e
p
a
g
e
54
S
ee
p
a
g
e
54
P
roce
ss
C
alibration Tool
s
Resources
Information for the classroom at
w
ww.fluke.com
/
education
38
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/pressure
F
luke 719 Electric Pressure Calibrator
s
El
ectr
i
c pump ena
bl
es one
h
an
d
e
d
pressure pump
i
ng an
d
m
a
k
es pressure ca
lib
rat
i
on qu
i
c
k
er an
d
eas
i
er
B
est in class
0
.
02
5 % pressure measurement accurac
y
P
rogramma
bl
e pump
li
m
i
t sett
i
ngs can e
li
m
i
nate over-
p
ressur
i
zat
i
on—set
pump to
pressure va
l
ue
s
T
wo ranges,
30
PSI and 1
00
PS
I
F
luke 71
8
Pressure
C
alibrator
s
1
,
30
, 1
00
and
300
PSI ranges availabl
e
Pump to
300
PSI,
20
bar with internal
p
ump
(
71
8
-300G)
7
1
8
-1G includes special low volume
p
ump and high measurement resolution
f
or low pressure calibration
F
l
u
ke 717 Pre
ssu
re
C
ali
b
rat
o
r
s
M
easure u
p
to 5000 PSI/345 bar sensor
(
5000G model
)
C
ompatible with non-corrosive gases
and li
q
uid
s
718
a
n
d
71
9
Precision vernier
f
or
f
ine
p
ressure
ad
j
ustmen
t
V
ariable release rate bleed valve
f
or
c
ontrolled
p
ressure release
717
,
718 and 719 common
f
eatures
Pressure switch test makes a difficult
tas
k
easy, captures set, reset an
d
d
ea
d
-
b
and values of a pressure switch
7
17 a nd 71
8
, measure pressure to
0
.
0
5 % of full scale with internal senso
r
M
easure mA with
0
.
0
15 % accuracy
and
0
.
00
1 mA resolution, while sourc
-
ing
2
4 V loop powe
r
Recommended kits
Resources
Specialty model
Specifications
Included accessories Models
T
est leads, alli
g
ator
clip
s,
h
o
l
ster, test
h
ose
(
719
)
, one 9 V alkaline
batter
y
(
two 9 V bat
-
teries in 71
8
and 719
)
,
s
a
f
ety sheet.
FLUKE-71
9
-
30G
E
le
c
tri
c
Pre
ss
ure
Ca
libr
a
t
o
r FLUKE-71
9
-1
00
G
E
le
c
tri
c
Pre
ss
ure
Ca
libr
a
t
o
r
FLUKE-718 1G Pre
ss
ure
Ca
libr
a
t
o
r FLUKE-718 30US Pre
ss
ure
Ca
libr
a
t
or
FLUKE-71
8
1
00
US Pre
ss
ure
Ca
libr
a
t
o
r FLUKE-71
8
3
00G
Pre
ss
ure
Ca
libr
a
t
or
FLUKE-717 1
G
Pre
ss
ure
Ca
libr
a
t
o
r FLUKE-717 3
0
G Pre
ss
ure
Ca
libr
a
t
or
FLUKE-717 1
00G
Pre
ss
ure
Ca
libr
a
t
o
r FLUKE-717 3
00G
Pre
ss
ure
Ca
libr
a
t
or
FLUKE-717
500G
Pre
ss
ure
Ca
libr
a
t
o
r FLUKE-717 1
000
G Pre
ss
ure
Ca
libr
a
t
or
FLUKE-717 1
500
G Pre
ss
ure
Ca
libr
a
t
o
r FLUKE-717 3
000
G Pre
ss
ure
Ca
libr
a
t
or
FLUKE-717
5000
G Pre
ss
ure
Ca
libr
a
t
o
r
For a full list of Fluke 700 Pressure Modules, visit www.fluke.com
/p
ressure
.
Ordering information
F
luke 717, 718 and 719 Pressure Calibrators
Accurate and rugged, temperature calibration tools
Fl
u
ke 7
00
Serie
s
Pre
ssu
re M
o
d
u
le
s
29
pressure module
s
8
intrinsically safe
p
ressure modules
*
R
anges
f
rom
1.
000
in
H
2
0
(
0.2491 kPa
)
t
o 1
0
,
000
psi
(
6
8
.94
8
MPa
)
G
age, differential,
d
ual
(
compound),
a
bsolute, and
v
ac
uum m
o
dule
s
R
ugged cases protect the modules
f
r
o
m h
a
r
s
h envir
o
nment
s
F
ull-accuracy per
f
ormance
f
rom
0
°
C to 50
°C
*
For use with 718Ex and 725Ex onl
y
(
see page 39 for more information)
.
Pressure
Enabled
F
luke Proce
ss
C
alibrator
s
in thi
s
cat
-
a
l
o
g
di
sp
l
ay
i
n
g
t
h
e
P
ressure
E
na
bl
e
d
symbol display readings from the
700
Serie
s
Pre
ss
ure Mo
d
ule
s.
Models Range Resolution Comment
7
17-1
+/
- 1
p
si, 27.5 in
H
2
0,
(
-7 - +7 kPa)
+0
.
000
1 psi,
0
.
000
1 kPa,
0
.
000
1 in H
2
0
Fluke-71
8
dr
y
air onl
y
and includes on board
p
um
p
718-1
G
717-3
0G
-12 to + 30
p
si,
(
-83 to 207 kPa
)
0
.001
p
si, 0.001 kPa, 0.001
in H
2
0
Fluke-71
8
and Fluke-719 dr
y
air onl
y
and
includes on board
p
um
p
718-30G* and
71
9
-
30G
717-1
00G
-12 to + 100
p
si,
(
-83 to 690 kPa
)
0
.01 psi, 0.01 kPa, 0.01 in
H
2
0
F
luke-718 and Fluke-719 dr
y
air onl
y
and
i
ncludes on board pum
p
71
8
-1
00
G
*
717-3
00G
-1
2
to +
300
psi,
(
-
8
3 to +2070 kPa) 0.01
p
si, 0.01 kPa, 0.01 in H
2
0
F
luke-718 dr
y
air onl
y
and includes on board
p
ump
71
8
-3
00
G* and
71
9
-1
00G
717-
500G
0-500 psi, 0-3450 kP
a
0.01 psi, 0.1 kP
a
Compatible with non-corrosive gases and fluid
s
717-1
000
G 0-1000 psi, 0-6900 kP
a
0.01 psi, 0.1 kP
a
Compatible with non-corrosive gases and fluid
s
717-1
500
G 0-1500
p
si, 0-10342 kPa 0.1
p
si, 1 kPa Compatible with non-corrosive gases and fluid
s
717-3
000
G 0-3000
p
si, 0-20700 kPa 0.1
p
si, 1 kPa Compatible with non-corrosive gases and fluid
s
717-
5000
G 0-5000
p
si, 0-34500 kPa 0.1
p
si, 1 kPa Compatible with non-corrosive gases and fluid
s
P
ressure accurac
y
0.05 % of range, one year for 717 and 71
8
. 0.025 % for six months, 0.035 % of range, one year for the 719
mA measurement 0-24 mA rang
e
0
.
00
1 mA resolution Accuracy: ± 0.015 % + 1 count
L
oo
p
p
owe
r
24 V dc Accuracy: ± 10
%
*Intrinsically safe models available, see page 39.
W
arranty:
Th
ree-
y
ear on ca
lib
rator, one-
y
ear on pump.
Pressure
Enabled
Fl
u
k
e
719
Fluke
718
Fluke
717
M
o
re inf
o
o
nline at
www.fluke.com
/
processtool
s
Check out the 71
9
video a
t
w
ww.fluke.com
/
719video
700
HTP-
1
C
11
6
Hydraulic Test Pump Large Soft Cas
e
S
ee pa
ge
59
S
ee pa
ge
54
7
00
ILF 7
00
LTP-1
I
n-
Li
n
e
Fil
t
er
L
ow
P
ressure
Se
e
page
59
T
est Pum
p
S
ee
page
59
P
roce
ss
C
alibration Tool
s
39
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/e
x
Resources
Specialty models
I
ntrinsicall
y
Safe Products
Calibrators, thermometers and multimeters
designed to intrinsic safety standards
Models Models
FLUKE-87VEx I
S
True-rm
s
Multimeter
F
LUKE-7
0
7Ex
I
S Loop
C
alibrato
r
FLUKE-71
8
E
x
I
S
Pre
ss
ure
Ca
libr
a
t
o
r
F
LUKE-72
5
Ex
IS
Multifu
c
ti
o
n Pr
oc
e
ss
Ca
libr
a
t
o
r
FLUKE-7
00
PEx
P
ressure Modules
(
700P: 01, 5, 6, 9, 24, 27,
29
, A4Ex
)
F
LUKE-
5
74-N
I
Precision Infrared Thermometer w
/
Logging SW
N
on
i
ncen
di
ve
FLUKE-68I
S
Infrared Thermometer Intrinsicall
y
Safe
What is “Intrinsically Sa
f
e”
?
Intrinsic safety is a protection method employed in potentially explosive atmospheres.
Devices that are certified as “intrinsically safe” are designed to be unable to release
s
ufficient energy, by either thermal or electrical means, to cause ignition of flammable
m
aterial (gas or dust
/
particulates)
.
T
here are no global intrinsically safe standards or certifications, but there are organi
-
zations that influence directives in certain world geographies
.
F
actory
M
utua
l
– In the United States, Factory Mutual Research,
managed by Factory Mutual
(
FM) Global, is a non-profit scientific and
testing organization that has tested and certified over 4
0
,
000
products
in the last 1
6
5 years. FM Research has set certification guidelines for
equ
i
pment use
d
i
n potent
i
a
ll
y exp
l
os
i
ve atmosp
h
eres
.
C
anadian Standards Association
(
CSA
)
– Accreditation body for
North American regulations, based in Toronto,
C
anada
.
ATEX
– The primary intrinsically safe standard, which has been set
in the European Union with the Directive 94
/
9
/
EC, commonly called
ATEX (“Atmosph
è
res Explosibles”), French for explosive atmospheres
.
For more information and detailed specifications, turn to the cor
-
r
esponding non-intrinsically safe product pages
(
Fluke 707, 71
8
, 725,
574, 6
8
) or go to
w
ww.fluke.com/e
x
.
Fluke products ATEX certified
North American
Certification
For additional
product detail
8
7V Ex: Intrinsicall
y
Sa
fe True-rm
s
Multimete
r
II
2
G
Ex ia II
C
T4
S
ee page 1
2
7
0
7Ex: Intrinsically
S
afe mA
C
alibrato
r
II
2
G Ex ia II
C
T4 N.I. Class I
,
Div 2
,
G
roups A-D T
4
S
ee page
3
4
718Ex: Intrinsically
S
afe Pressure
C
alibrato
r
II 1 G Ex ia IIC T4
G
rou
p
s A-D T
4
See pa
g
e 3
8
7
25Ex: Intrinsicall
y
Safe
M
ultifun
c
ti
o
n
Ca
libr
a
t
or
II 1 G Ex ia IIB 171 °C
Groups B-D, 171 °
C
See page
36
700
PEx: Intrinsically
Safe Pressure Module
s
II 1 G Ex ia IIC T4
I.S. Class I, Div 1,
G
rou
p
s A-D T
4
See pa
g
e 38
Fluke
5
7
4
-NI Nonincendive
I
nfr
a
red Therm
o
mete
r
C
lass I
,
Division
2,
Groups A, B,
C
, D;
C
lass I
,
Zone
2
II
C
S
ee page 5
0
Fluke 6
8
IS Intrinsically Safe
In
f
rared Thermomete
r
C
lass I, Division 1,
G
rou
p
s A, B,
C
, D
C
lass I, Zone
0
AEx
i
a II
C
Fluke 68IS Intrinsically Safe
In
f
rared Thermometer
L
aser guided sighting
system with 1 % accuracy
1
2
-point data loggin
g
A
dvanced optic
s
A
djustable emissivit
y
S
electable Max
/
Min
/
Dif
/
Avg
f
unctions that display values
i
nstantly with Hi
/
Lo Alarm
E
xpanded measurement
range up to 760
°
C (1400
°
F)
R
TD probe accessory included
C
lass I, Division 1, Groups A,
B,
C
, D
C
lass I, Zone
0
, AEx ia II
C
,
T4 at 50
°
C when used with 9 V
a
lkaline batter
y
Not available for purchase in Europe.
574
-
NI
N
o
nincendive
Therm
o
mete
r
F
or data loadin
g
a
nd extra sa
f
ety
t
he Fluke
5
7
4
N
onincendive
(
NI
)
Therm
o
meter h
as
t
he same great
f
eatures as the 574
m
o
del therm
o
meter with the extr
a
con
-
f
idence o
f
a Factory Mutual approval
fo
r u
s
e in h
a
z
a
rd
o
u
s
envir
o
nment
s.
C
lass I, Division 2, Grou
p
s A, B, C, D: Class I, Zone 2 IIC;
T
4 Ta=50 °C when used with 1.5 V alkaline batteries.
More in
f
o online at
www.fluke.com/
p
rocesstool
s
Take a look at all the intrinsically sa
f
e
m
od
e
ls
a
t
w
ww.fluke.com
/
insafet
y
Ordering information
P
roce
ss
C
alibration Tool
s
A
ll the information you need at
w
ww.fluke.com
/
processsolutions
40
For more in
f
ormation,
g
o to www.
f
luke.com/scopemeter
S
copeMeter Test Tools
F
luke Sco
p
eMete
r
®
Test Too
ls
Handheld oscilloscopes for industrial,
instrumentation and electronic applications
S
copeMeter test tools are the ru
gg
ed, safe choice for a wide
variet
y
of field service installation and maintenance applications.
Th
ese
h
an
dh
e
ld
b
atter
y
-powere
d
osc
ill
oscopes too
l
s are eas
y
to
use, w
i
t
h
a
b
u
il
t-
i
n mu
l
t
i
meter, paper
l
ess recor
di
n
g
an
d
ana
ly
s
i
s
c
apabilities. The
y
are ru
gg
ed and IP 51 dust- and drip-proof rated
to IEC
5
29 standards to withstand harsh environments
.
T
he new 190 Series II, four isolated in
p
ut channels and
100
MHz or 2
00
MHz bandwidth are ideal for industrial machi
n
-
e
r
y
app
li
cat
i
ons measur
i
n
g
t
h
ree-p
h
ase power e
l
ectron
i
cs or
t
h
ree-ax
i
s contro
l
s
y
stems compar
i
n
g
an
d
contrast
i
n
g
mu
l
t
i
p
l
e
s
i
g
nals simultaneousl
y
. These tools are safet
y
, rated at CAT III
1
000 V
/
CAT IV 600 V with lon
g
er batter
y
life and up-to-date
U
SB interface technolo
gy.
T
he 190C Series, with two isolated in
p
uts and 60 MHz,
1
00 MHz or 200 MHz bandwidth
,
is the choice for industrial
el
ectron
i
c a
ppli
cat
i
ons
lik
e automat
i
on an
d
p
rocess contro
l
.
Th
ese
o
scillosco
p
es are rated for CAT II 1000 V
/
CAT III 600 V environ
-
m
ents and will operate for up to four hours without a rechar
g
e.
T
he 120 series with 20 MHz or 40 MHz bandwidth
,
dual DMMs
and paperless recordin
g
is the optimal choice for electrical and
e
lectro-mechanical applications, safet
y
rated to IEC EN61010-1
CAT III
600
V
.
F
or Industrial network a
pp
lications, Fluke 125, 215C or 225C
a
dd
i
n
d
ustr
i
a
l
networ
k
p
hy
s
i
ca
l
l
a
y
er ana
l
o
g
measurement a
lgo
-
r
i
t
h
ms to va
lid
ate t
h
e networ
k
b
us
h
ea
l
t
h
.
TM
120 Series 190C Series 190 Series II
123 124 125 215C 225C 192C 196C 199C 190-104 190-204
Bandwidth
20 MHz
40 MHz ••
60 MHz
100 MHz • •
200 MHz • •
Input channels
2Ch + 2 DMM • • •
2Ch + DMM • • • • •
4Ch • •
Isolated inputs • • • • • • •
Triggering
Connect-and-View • • • • • • • • • •
Advanced triggering • • • • • • •
Advanced measurement function
Cursors • • • • • • • • •
TrendPlot • • • • • • • • • •
ScopeRecord • • • • • • •
100 screen replay • • • • • • •
Industrial bus health • • •
Harmonics
FFT • • • • • • •
Power measurements • • • • • • • •
Waveform mathematics • • • • • • • •
EN61010-1 safety
CAT II 1000 V • • • • • • •
CAT III 600 V • • • • • • • • • •
CAT III 1000 V • • • • • • •
CAT IV 600 V • •
Interface
Optical RS-232 • • • • • • • •
USB PC interface Opt Opt Opt Opt Opt Opt Opt Opt • •
USB memory port • •
Power
Ni-MH • • • • • • • •
Li-Ion • •
Battery (hours) 7774444477
General specifications
Size (HxWxD) 9.2 in x 4.5 in x 2 in 10.1 in x 6.7 in x 2.5 in 10.5 in x 7.5 in x 2.8 in
Weight 2.6 lb 4.4 lb 4.8 lb
F
luke 225
C
Selection guide
Fluke 199
C
F
luke 124
41
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to www.fluke.com/scopemete
r
S
co
p
eMeter Test Tools
Recommended accessories
Recommended kits
Resources
Co
nnect-and-View
tri
gg
erin
g
for an
instant, stable displa
y
S
cope users know how difficult triggerin
g
can be. Incorrect settings show unstable and
s
ometimes incorrect results. Flukes unique
C
onnect-and-View recognizes signal patterns
and automatically and continuously sets up
correct triggering. It provides a stable, reliable
and repeatable display o
f
virtually any signal
.
U
s
e TrendPl
ot
to help find intermittent
s
T
he toughest
f
aults to
f
ind are those that
h
appen only once in a while—intermittents.
T
hey can be caused by bad connections, dust,
d
irt, corrosion or simply broken wiring or con
-
n
ectors.
O
ther factors, like line outages and
s
ags, can also cause a machine to stop. You
m
ay not be around to see it—your Fluke
S
cop
e
-
M
eter will. In this “paperless recorder” mode,
y
ou can plot the minimum and maximum peak
v
alues and average over time—up to 1
6
days
.
B
atter
y
powered mobilit
y
U
p to seven hours o
f
battery operation
f
rees
y
ou
f
rom mains outlets
f
or true on-the-move
w
orking. The rugged and drip proo
f
case
assures long li
f
e and reliable operation in the
ha
r
s
he
s
t indu
s
tri
a
l envir
o
nment
s
.
S
afet
y
rate
d
T
he ScopeMeter 1
23
and 1
2
4 are safety
rated for measurements on
C
AT III
600
V rms
industrial power systems with the included
te
s
t le
a
d
s
.
Fl
u
k
e 123 an
d
124
ScopeMeter
®
Test Tools
Th
ree-
i
n-one s
i
mp
li
c
i
t
y
T
he compact ScopeMeter 1
23
and 1
2
4 are
the rugged solution for industrial troubl
e
-
sh
oot
i
ng an
d
i
nsta
ll
at
i
on app
li
cat
i
ons.
E
ac
h
i
s a tru
l
y
i
ntegrate
d
test too
l
, w
i
t
h
o
sc
ill
oscope, mu
l
t
i
meter an
d
paper
l
ess
recorder in one affordable, easy-to-use
i
nstrument. Find fast answers to problems
i
n mac
hi
nery,
i
nstrumentat
i
on, contro
l
an
d
power systems
.
D
ual-input 4
0
MHz or
20
MHz digital
o
sc
ill
oscope
T
wo 5,
000
-count true-rms digital
m
u
l
t
i
meter
s
A
d
ua
l
-
i
nput
T
ren
dPl
o
t
recor
d
er
C
onnect-and-View
tr
i
gger s
i
mp
li
c
i
ty
f
or hands-off operation
Shielded test leads for oscillo-
scope, res
i
stance an
d
cont
i
nu
i
ty
measuremen
t
s
U
p to seven
h
ours
b
attery operat
i
on
C
AT III
600
V safety certified
Optically isolated RS-
232
interfac
e
IP
51
rate
d
, rugge
d
compact cas
e
I
mprove your trou
bl
es
h
oot
i
ng
skills, Fluke can hel
p
!
Visit the ScopeMeter Training
C
enter
:
www.fluke.com/ScopeMeterTrainin
g
C
enter
S
CC
1
20
Ki
t
S
oftwar
e
Cable
H
ard carrying cas
e
S
CC
1
90
Kit
S
oftwar
e
Cable
H
ard carrying cas
e
Ordering information
Included accessories Models
T
est
l
ea
d
set, a
llig
ator c
li
ps,
h
oo
k
c
li
ps,
b
atter
y
pac
k
,
b
atter
y
char
g
er/line volta
g
e adapter, BNC adapter,
g
ettin
g
started
guide, users manual on CD.
FL
U
KE-1
2
4
S
Industrial ScopeMeter, 4
0
MHz, with S
CC
1
20
kit
FL
U
KE-1
2
4 Industrial ScopeMeter, 4
0
MHz
FLUKE-12
3
S Industrial ScopeMeter, 20 MHz, with SCC120 kit
FLUKE-12
3
Industrial ScopeMeter, 20 MHz
T
est
l
ea
d
set, a
lli
gator c
li
ps,
h
oo
k
c
li
ps,
b
attery pac
k
,
b
attery
char
g
er
/
line volta
g
e adapter, BNC adapter, OC4USB opticall
y
i
solated RS-232 ada
p
ter/cable, FlukeView for Sco
p
eMeter
W
ind
o
w
s
®
so
f
tware, hard carr
y
in
g
case,
g
ettin
g
started
guide, users manual on CD.
S
CC12
0
Kit containing FlukeView so
f
tware
f
or Windows,
U
SB interface adapter
/
cable and hard case
C
1
25
C
1
95
Soft
C
arr
y
in
g
C
as
e
T
oo
l
B
a
g
See
page
54
S
e
e
page
54
PA
C91
i
30s
Printer Ada
p
ter Cable AC/DC Current Clam
p
S
ee pa
g
e
61
C
onnect-and-View captures even the most
comp
l
ex motor
d
r
i
ve s
ig
na
l
s.
U
se TrendPlot to help find intermittents, fast.
42
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Resources
Sample screens
F
luke 190 Series II Sco
p
eMete
r
®
Test Too
ls
See more, x more, in harsh industrial environments
G
oes where ordinary scopes can’t g
o
S
afety rated for industrial applications, the 1
90
S
eries ScopeMeter combines rugged portability
w
ith high performance to take you all the way
from troubleshooting microelectronics to power
el
ectron
i
c app
li
cat
i
ons
.
The
f
irst hi
g
h-per
f
ormance
f
our-channel scopes
bu
ilt
fo
r har
s
h ind
us
trial envir
o
nment
s
F
or the
f
irst time, plant maintenance en
g
ineers and
technicians can take a hi
g
h-per
f
ormance
f
our-
c
hannel sco
p
e into the harsh world o
f
industrial
e
lectronics. The new Fluke 19
0
Series II is the
o
nl
y
portable oscilloscope with
f
our independent
i
solated in
p
ut channels, a CAT III 1000 V/CAT
IV 600 V safet
y
ratin
g
, and an IP 51 dust-proo
f
and drip-proof ratin
g
. Both the 200 MHz (Fluke
1
90-204
)
and 100 MHz
(
Fluke 190-104
)
bandwidth
m
odels o
ff
er these ca
p
abilities
:
4 inde
p
endent isolated in
p
uts, u
p
to 1000
V
Hi
g
h-speed samplin
g
: Up to 2.5 GS/se
c
Deep memor
y
: 10,000 points per trace waveform
c
a
p
tur
e
CAT III 1000 V/CAT IV 600 V safet
y
rated for
h
i
g
h volta
g
e environments
Up to 7 hours o
f
batter
y
operation, standard
Isolated U
S
B host port for direct data stora
g
e to a
U
S
B memor
y
Device, plus USB device port for eas
y
PC
co
mmuni
ca
ti
o
n
E
as
y
-access batter
y
door
f
or quick batter
y
swaps
i
n the
f
iel
d
Compact and onl
y
2.2 k
g
(4.8 lb)
S
ecurit
y
slot: lock down oscilloscope with
Kensin
g
ton lock while unattended
Ordering information
Included accessories Models
T
est
l
ea
d
set, vo
l
tage pro
b
es
(200 MHz, 10:1)-red and
g
ra
y
,
batter
y
char
g
er/line volta
g
e
adapter, battery pack, getting
s
tarte
d
g
u
id
e, users manua
l
on
C
D.
FLUKE-19
0
-2
0
4 Color ScopeMeter (200 MHz, 2.5 GS
/
s, 4 channel)
FLUKE-19
0
-2
0
4S Color Sco
p
eMeter (200 MHz , 2.5 GS
/
s, 4 channel), with SCC290-kit
FLUKE-19
0
-1
0
4 Color Sco
p
eMeter (100 MHz, 1.25 GS
/
s, 4 channel)
FLUKE-19
0
-1
0
4S Color Sco
p
eMeter (100 MHz, 1.25 GS/s, 4 channel), with SCC290-kit
FLUKE-199
C
Color Sco
p
eMeter (200 MHz, 2.5 GS/s)
FLUKE-199C
/
S Color Sco
p
eMeter (200 MHz, 2.5 GS/s) + SCC190
FLUKE-19
6C
Color Sco
p
eMeter (100 MHz, 1 GS/s)
FLUKE-196C
/
S Color Sco
p
eMeter (100 MHz, 1 GS/s) + SCC190
FLUKE-1
92C
Color Sco
p
eMeter (60 MHz, 500 MS/s)
FLUKE-192C
/
S Color Sco
p
eMeter (60 MHz, 500 MS/s) + SCC190 kit
U
se the
2
7,
000
points memor
y
of ScopeRecord and
zoo
m in f
o
r m
a
ximum det
a
il.
C
ursors and zoom features of the Fluke 1
90
Series help
you to analyze the captured TrendPlot
.
C
onnect-and-Vie
w
ca
p
tures even the most com
p
lex
motor drive signals.
A
utomatic capture and repla
y
of
1
00
s
creen
s
S
cope users know how frustrating it is to
s
ee a one-time anomaly
f
lash by—never
to be seen again. Not with the
S
copeMeter
190
series. Now you can look back in
time with a touch o
f
the replay button. In
normal use, the instrument continuously
m
emorizes the last 1
00
screens, on a first
i
n-
f
irst out basis. At any moment you can
freeze” the last 1
00
screens and scroll
through picture-by-picture or replay as a
live”
a
nim
a
ti
o
n.
C
ur
so
r
s
ca
n be u
s
ed f
o
r
f
urther analysis
.
ScopeRecordmode for hi
g
h-resolution
w
aveform recordin
g
up to 4
8
hours
S
copeRecord memory stores up to
2
7,
000
d
ata points per channel, capturing
f
ast
i
ntermittents and glitches as short as 8ns.
S
tores events like motion profiles, UP
S
,
p
ower supply and motor start-up
s
I
n
S
top
O
n Trigger mode,
S
copeMeter
automatically recognizes a power
f
ailure
a
nd
s
t
o
re
s
the w
a
ve
fo
rm d
a
t
a
W
ith the waveform zoom
(
up to 100x)
you can look at the smallest details, like
individual power cycle
s
T
rendPlot Paperless Recorde
r
The toughest
f
aults to
f
ind are those that
ha
pp
en once in a while. These intermit
-
tents can be caused by bad connects,
dust, dirt, corrosion, or sim
p
le broken
wiring or connectors. Line outages, sags
or starting and stopping o
f
a motor can
also cause a machine to stop. You may not
be around when it happens, but the Fluke
S
copeMeter will.
P
lot minimum and maximum plot values
a
nd average over time up to 1
6
day
s
P
lot any combination o
f
voltages, amps,
temperature,
f
requency and phase
f
or
a
ll
f
our inputs, all with time and date
stamp to pinpoint
f
aults
G
o to
w
ww.fluke.com
/
fourchanne
l
-
scopemeter
for interactive trouble
r
-
shooting demonstrations.
For more information, go to
w
ww.
f
luke.com/sco
p
emeter
ScopeMeter Test Tool
s
Fluke
190
-
204
Fl
u
k
e
199C
43
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Sample screens
Specifications
Included accessories Models
T
est
l
ea
d
set,
b
attery
char
g
er
/
line volta
g
e
adapter, batter
y
pac
k
(
installed), getting
s
tarte
d
gu
id
e, mu
l
t
i
-
li
n
g
ua
l
users manua
l
on
C
D.
F
LUKE-225C
/
00
3
C
olor ScopeMeter (200 MHz, 2.5 GS
/
s) with Bus Health test capabilities built-in
F
LUKE-225C
/
003
S
C
olor ScopeMeter (200 MHz, 2.5 GS
/
s) with Bus Health test capabilities built-in,
w
ith S
CC
1
90
kit
F
LUKE-215C
/
00
3
C
olor ScopeMeter (100 MHz, 1 GS/s) with Bus Health test capabilities built-in
F
LUKE-215C
/
003
S
C
olor ScopeMeter (100 MHz, 1 GS/s) with Bus Health test capabilities built-in, with
S
CC-ki
t
F
LUKE-12
5
Industrial Sco
p
eMeter, Bus Health, Power & Harmonics
F
LUKE-1
2
5
S
Industrial Sco
p
eMeter, Bus Health, Power and Harmonics with S
CC
-Kit
Ordering information
Resources
he Fluke
22
5
C
,
2
15
C
and 1
2
5
re the in
s
trument
s
of
c
h
o
i
c
e
fo
r
m
aintenance specialists who deal
w
ith indu
s
tri
a
l bu
s
e
s
a
nd netw
o
rk
s
s well as general electronics. You
a
n veri
f
y the electrical integrity
f
your bus and network physical
a
yer, per
f
orming tests and getting
nswers to digital signalling issues
uickly and easily.
T
he
s
e in
s
trument
s
off
er
a
ll
h
e functions found in the 1
20
or
90C
Series, plus added measur
e
-
m
ent capabilities
f
or industrial
n
etw
o
rk
s
s
u
c
h
as
Pr
ofi
®
,
Founda
-
io
n
,
Modbus
®
,
C
AN-bus, AS-i bus,
R
S-4
8
5 and more.
B
us Health physical layer appl
i
-
a
tion measures critical digital
i
gnal amplitude, time and noise
r
di
s
t
o
rti
o
n
c
h
a
r
ac
teri
s
ti
cs
. Find
errors like signal attenuation and distortion caused by improper cable connections, bad
c
ontacts, incorrect grounding, and missing or superfluous terminators.
S
ignal integ
-
rity analysis is extended with the eye-pattern mode. A wave
f
orm display is built over
successive signal passes to give you a visual indication o
f
overall signal quality, noise
l
evels, and signal jitter.
C
ritical bus physical layer amplitude, time and
n
o
i
s
e
o
r di
s
t
o
rti
o
n me
as
urement
s
C
ompare measurement results to limits defined by
t
he industry standard
Display clear “good”, “weak” or “bad” indicators
.
E
ye pattern mode to visually inspect wave
f
orms
q
uality o
f
transmitted data packet
s
2
15
C
or
22
5
C
with isolated inputs perform floating
d
i
ff
erenti
a
l me
as
urement
s
o
n b
a
l
a
n
c
ed tw
o
wire
b
us system
s
1
2
5 dual input measurements performed relative to
c
ommon re
f
erence poin
t
BHT1
90
breakout adapter set DB
9
, RJ45 and M1
2
simpli
f
y probing onto bus signal connector
s
F
luke 225C, 215C and 125
Sco
p
eMeter
®
Test Too
l
s
Fluke 225C
(200 MHz 199C)
Fluke 215C
(100 MHz 196C)
Fluke 125
(40 MHz 124)
D
ual isolated inputs for differential bus s
y
stem probin
g
O
n screen bus system probe connection diagrams
B
u
s
H
e
al
t
h
Phy
s
i
ca
l
L
a
y
er
S
t
a
nd
a
rd
s
AS
-i
C
AN-bus
(
ISO-11
8
9
8)
(
DeviceNet
)
Interbus S
(
EIA-4
8
5
)
C
ontrolNet
(
6115
8
type 2)
M
odbus
(
EIA-232, EIA-4
8
5
)
Foundation Fieldbus H1
(
6115
8
type 1)
Profibus DP
(
EIA-4
8
5), PA
(
6115
8
type 1)
E
thernet 10Base2
(
coax), 10BaseT
(
UTP)
E
thernet 100BaseT (100 Mb/s)
RS-232
(
EIA-232), RS-4
8
5
(
EIA-4
8
5)
M
easured parameter
s
B
ias Volta
g
e Level, si
g
nal amplitude,
p
ulse width or baud rate, rise/ fall time, jitter,
si
gna
l
di
stort
i
on, no
i
se
HF
, no
i
se
LF
,
i
n-
b
an
d
no
i
se
B
aud rate
,
rise/fall
t
ime, high level,
l
ow
l
eve
l
,
di
stort
i
on,
a
mp
li
tu
d
e,
ji
tter
Ey
e dia
g
ram “qualitative” waveform anal
y
sis
B
us
H
ea
l
t
h
b
rea
k
out a
d
apter set BHT1
90
included BHT1
90
optional
U
se “e
y
e” dia
g
rams to inspect
f
or issues like si
g
nal
no
i
se,
di
stort
i
on an
d
ot
h
er common
di
stur
b
ances
.
M
easure critical si
g
nal characteristics, compare to
i
ndustry standard
.
G
o to
w
ww.fluke.com
/
sco
p
emeter-
f
a
qs
f
or answers to
f
requently asked
q
uestions
.
i41
0
A
C
/
DC
C
urrent
C
lam
p
S
e
e
page
6
1
BHT1
90
i
30
S
Bus Health Test Ada
p
ter, AC
/
D
C
DB-9 and M-1
2
Current Clam
p
S
e
e
p
a
g
e
6
1
F
or more in
f
ormation,
g
o to www.fluke.com/scopemete
r
S
co
p
eMeter Test Tools
44
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/thermal_ima
g
in
g
Th
erma
l
I
ma
gi
n
g
Application tips
Resources
S
uperior ima
g
e quality
Just pick up a Fluke imager and you’ll immediately see the differ
-
e
nce. Fluke delivers the clear, crisp images needed to find and fix
p
roblems fast
.
I
ndustry leading thermal sensitivity
(
NETD) enables you to
i
dentify the small temperature differences that could indicate
bi
g pro
bl
ems
E
ven t
h
e sma
ll
est
d
eta
il
s
b
ecome v
i
s
ibl
e w
i
t
h
t
h
e
l
arge, w
ide
-
s
creen full VGA color L
C
D display
P
atente
d
IR
-
F
us
i
o
n
®
Easy to use
When you pick up a tool, you need it to operate and deliver results
w
ithout having to read a heavy manual
Intuitive, three-button menu is easy to use… simply navigate
w
ith the push o
f
a thum
b
Add comments quickly and easily with voice annotation feature
f
or precise image viewing contro
l
IR
-
F
us
i
on v
i
ew
i
ng mo
d
es
Fl
u
k
e T
h
erma
l
Imag
i
n
g
Find it, x it, fast
Electric motors
and
p
um
p
s
Hot spots may
b
e an early indi
-
ca
t
o
r
of
m
o
t
o
r
winding prob
-
l
em
s
. Elev
a
ted
t
empera
t
ures
c
an damage
winding insula
-
t
ion, resulting
i
n operational
i
ne
ff
i
c
ien
c
ie
s
a
nd premature
m
o
t
o
r
fa
ilure. An
o
verheated motor may be an indic
a
-
t
i
o
n
of
a
n underr
a
ted m
o
t
o
r in the
a
pplication, insu
ff
icient cooling or
electrical power problems
.
B
u
s
bar
s
an
d
fu
s
e boxe
s
Tem
p
erature
d
ifferences
b
etween
p
hases
ma
y
indicate
u
nbalanced
l
oads
,
harmon
-
i
cs, com
p
onent
p
roblems, bad
c
onnections
o
r bad wirin
g
.
These condi
-
t
ions can result
i
n increased
ener
gy
cost and can dama
g
e cables
o
r machines or possibl
y
cause
f
ire.
E
ven small tem
p
erature di
ff
erences
b
etween
p
hases should be investi
-
g
ated to determine the root cause.
R
es
id
ent
i
a
l
an
d
c
ommerc
i
a
l
ener
g
y
l
oss
Mi
ss
i
ng or
i
mproper
l
y
i
nsta
ll
e
d
i
nsu
l
a-
ti
on
,
mo
i
sture
,
a
n
d
a
i
r
l
ea
k
s
revea
l
oppo
r
-
t
unities for
p
roper
t
y owners
t
o
l
ower t
h
e
i
r
energy cos
t
s.
S
ave time and
money by finding problems fast and
ensur
i
ng repa
i
rs are
d
one correct
l
y
.
In
f
rared ima
g
es alone can be di
ff
icult to
understand, which is wh
y
Fluke pioneered
IR-Fusion, a revolutionar
y
marria
g
e o
f
vis
-
i
ble and in
f
rared ima
g
es never be
f
ore seen
i
n commercial or industrial thermal ima
g
ers.
A
utomaticall
y
capturin
g
a visible ima
g
e with
e
ver
y
in
f
rared ima
g
e allows
y
ou to alwa
y
s
k
now exactly what you’re looking at.
D
on’t be
f
ooled b
y
imitators. Patented
I
R-Fusion is the onl
y
solution with ph
y
si
-
cal parallax correction, enablin
g
the per
f
ect
ali
g
nment and smooth blendin
g
o
f
both
in
f
rared and visible ima
g
es. While man
y
m
anu
f
acturers have attem
p
ted to du
p
licate
Fluke IR-Fusion, none have been able to
ma
t
c
h it. Turn t
o
Fluke IR-Fu
s
i
o
n t
o
deliver
the industry’s best thermal images.
F
u
ll
IR
P
i
c
ture in Pi
c
ture
A
lpha Blendin
g
F
ull Visible Light
I
R
/
Visible Alarm
T
o re
q
uest more in
f
ormation,
or a demonstration
,
or to order
,
c
all 1-800-760-4523 (U.S. onl
y
),
all other regions 1-4
2
5-44
6
-4
620
.
R
ugge
d
T
oo
l
s are meant to
b
e use
d
, an
d
Fl
u
k
e t
h
erma
l
i
magers are
d
es
i
gne
d
t
o re
li
a
bl
y operate
i
n t
h
e toug
h
est
e
nv
i
ronments
.
E
ng
i
neere
d
an
d
teste
d
to
w
ithstand a 2 m
(
6.5 ft) drop—
wh
en was t
h
e
l
ast t
i
me you
d
ropped a tool
?
S
ee the proof at
www.fluke.com/ru
gg
e
d
I
R-Fus
i
on
®
Tec
h
no
l
og
y
Not all fusion is created equal
Use in ambient temperatures as low as -10 °C (14 °F) and high as +50 °C (122 °F)
Protected by two-year warranty, with one- or two-year extended warranties available
A
sk
y
our Fluke representative for more details.
45
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/thermal_ima
g
in
g
Th
erma
l
I
ma
gi
n
g
Unsure where to begin with your new thermal imager
?
D
on
t worry.
Fl
u
k
e ut
ili
zes an
e
xtensive network of industry
e
xperts to deliver a full portfolio
o
f training solutions
.
F
ree
i
n-
b
ox tra
i
n
i
n
g
DVD:
Thi
s conven
i
ent tra
i
n
i
ng
s
o
l
ut
i
on prov
id
es a genera
l
i
ntro
d
uct
i
on to t
h
erma
l
i
mag
-
i
ng, product information, and
c
ommon app
li
cat
i
ons.
F
ree on
li
ne we
bi
nars
:
Fl
u
k
e
o
ffers both pre-recorded and
li
ve we
bi
nars to meet t
h
e nee
d
s
o
f busy professionals. Visit
www.fluke.com/titrainin
g
for
c
ourse
li
st
i
ngs an
d
sc
h
e
d
u
l
es.
H
an
d
s-on tra
i
n
i
n
g
sem
i
nars
:
Join us for one of our many local seminars where Fluke Thermography experts will
teac
h
b
as
i
c t
h
ermograp
h
y w
i
t
h
h
an
d
s-on
d
emonstrat
i
ons.
G
o to www.fluke.com/titrainin
g
for schedules
.
Ad
vance
d
tra
i
n
i
n
g
:For advanced thermography
(
Level I to
L
evel III
)
and application specific training either online, in
t
h
e c
l
assroom or at your s
i
te, s
i
gn up t
h
roug
h
Fl
u
k
e aut
h
o
-
r
i
ze
d
,
i
n
d
epen
d
ent tra
i
n
i
ng partners.
Vi
s
i
twww.fluke.com
/
t
i
tra
i
n
i
n
g
for training options and schedules
.
Palette samples
F
luke SmartVie
w
®
Softwar
e
Analysis and reporting software
I
ron
b
o
w
B
l
ue
-r
ed
High
contras
t
Ambe
r
H
ot meta
l
G
re
y
Fluke
p
alette o
p
tions
(
six of
1
6 available, varies by model)
P
owerful
E
verything you need
f
or analysis and
report
i
ng.
E
xtens
i
ve annotat
i
on, e
di
t
i
ng an
d
viewing options with
f
ull IR-Fusion
®
capa
bili
t
i
e
s
M
u
l
t
i
p
l
e report
i
ng opt
i
ons an
d
temp
l
ates
and
3
D-IR™ for unique
3
D analysi
s
Eas
y
to use
S
martView tools and controls allow easy
access to editing
f
unctions and its easy
d
rag and drop text annotation
f
eature
R
eport Wizard guides you through aut
o
-
m
atic, pro
f
essional report generation
I
nc
l
u
d
e
d
w
i
t
h
every
i
ma
g
er
F
luke in
c
lude
s
S
m
a
rtView
so
ftw
a
re with
unlimited licenses and li
f
etime up
g
rades
w
ith ever
y
thermal ima
g
er
N
o need to pa
y
extra
f
or a pro
f
essional
sof
tw
a
re
so
luti
on
S
martVie
w
®
sys
t
em
r
e
q
uirements
So
f
tware re
q
uirement
s
Wind
o
w
s
® XP SP2
/
Vista
/
7
A
web browser
f
or product registration
a
nd web u
p
date
s
Internet Ex
p
lorer 5.
0
or newer
5
12 MB of RAM minimum
(
1 GB for Vista
or 7
)
360
MB of hard disk s
p
ace for
p
roduct
i
n
s
t
a
ll
a
ti
o
n
M
i
c
r
osoft
®
Word
200
7 for re
p
ort tem
-
p
late modification (o
p
tional
)
H
ar
d
ware requ
i
rement
s
Memory card reader to transfer images
to computer
(
included)
512 MB RAM
(
1GB for Vista), not includ
-
ing the space requirements for web
browser and Microsof
t
®
W
o
r
d
1
6-bit color, 1024x768 resolution video
o
r better
C
D-ROM drive for installing SmartView
sof
tw
a
r
e
Fluke authorized trainin
g
is provided by our partner
,
F
luke Training Solutions
Getting started with Fluke Ti Thermal Imagers
4
6
Specialty models
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/thermal_ima
g
in
g
Resources
Features TI32 TI25 Ti10
Temperature measurement ran
g
e
(not calibrated below -10
°
C)
-2
0
°
C to +
600
°
C
(
-4
°
F to + 1112
°
F)
-2
0
°
C to +3
50
°
C
(
-4
°
F to + 662
°
F
)
-2
0
°
C to +2
50
°
C
(
-4
°
F to + 482
°
F
)
T
emperature measurement accurac
y
±
2 °C or 2 % (at 25 °C nominal, whichever is greater) ± 5
°
C or 5 %
(
at 25
°
C nominal,
w
hichever is
g
reater)
On-screen emissivity correction
Y
e
s
On-screen reflected background
tem
p
erature com
p
ensat
i
o
n
Y
e
s
O
n-screen transmission correction
Y
es
Image capture frequency
60
Hz or
9
Hz refresh rate depending on model
D
etector type
320
X
2
4
0
Focal Plane Array,
un
cool
e
d
m
ic
r
obolo
meter 160 X 120 Focal Plane Arra
y
, uncooled
T
hermal sensitivit
y
(
NETD)
0.05
°
C at 30
°
C tar
g
et temp.
(
50 mK
)
≤ 0.1
°
C at 30
°
C tar
g
et temp.
(
100 mK)
≤ 0.2
°
C at 30
°
C tar
g
et temp.
(
200 mK)
Field of view
(
standard lens)
F
ield of View: 23
°
x 17
°
; Minimum Focus Distance: 15 cm (approx. 6 in)
S
p
atial resolution (IFOV) 1.
2
5 mRad
2
.5 mRa
d
Optional telephoto infrared lens
Y
e
s
O
ptional wide-an
g
le infrared lens
Y
e
s
Standard
p
alette
s
Ironbow, Blue-Red, High
C
ontrast,
A
m
b
er,
A
m
b
er
I
nverte
d
,
H
ot
M
eta
l
,
G
ra
y
scale,
G
ra
y
scale Inverted
Ironbow, blue-red, hi
g
h contrast,
a
mber, hot metal, gre
y
Ironbow, blue-red, hi
g
h contrast,
g
r
ey
Ul
tra contrast
p
a
l
ettes
I
ron
b
ow
Ul
tra
,
Bl
ue-
R
e
d
Ul
tra
,
High
C
ontrast Ultra, Amber Ultra,
A
m
b
er
I
nverte
d
Ul
tra,
H
ot
M
eta
l
U
ltra,
G
ra
y
scale Ultra,
G
ra
y
scale
I
nverted Ultra
IR
F
u
sion
®
Y
e
s
C
olor alarms
(
user selectable)
H
igh-temperature alarm
V
oice annotatio
n
60 seconds maximum recordin
g
time per ima
g
e; reviewable pla
y
back
o
n ima
g
er
S
torage mediu
m
S
D memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual
ima
g
es each with 60 seconds voice annotations, or 3000 basic bitmap
(
.bmp) ima
g
es, or 3000
j
pe
g
(
.
j
pe
g
)
ima
g
es; transferrable to PC via included multi-format USB card reader
E
x
p
ort file formats w
/
included
S
m
a
rtVie
w
®
So
ftw
a
re BMP, DIP,
G
IF, JFIF, JPE, JPE
G
, JP
G
, PN
G
, TIF, and TIFF
B
atter
i
es
T
wo
Li
t
hi
um
I
on rec
h
argea
bl
e
smart
b
attery pac
k
s w
i
t
h
5
-seg
-
m
ent
LED
Di
sp
l
ay to s
h
ow c
h
arge
l
evel. Battery life: 4+ hours;
Batter
y
char
g
e: 2.5 hours to full
c
har
ge
I
nternal rechar
g
eable batter
y
pack
(
included)
B
atter
y
life: 3-4 hours
B
attery charge:
2
.5 hours to full charge
AC
battery chargin
g
Two-bay A
C
battery charger
(
110 V ac to 220 Vac, 50
/
60 Hz
)
(
included), or in-ima
g
er char
g
in
g
,
ac mains adapters included
A
C adapter/char
g
er (110 V ac to 220 V ac, 50/60 Hz) (included),
charges battery while imager is operating or turned o
ff
, ac mains
ad
a
p
ters
i
nc
l
u
d
e
d
A
C
o
p
eration
A
C operation with included power supply (110 V ac to 220 V ac, 50
/
60 Hz), ac mains adapters included
Enclosure ratin
g
IP5
4
D
rop tested
2
m
(
6.5 ft)
W
arrant
y
T
wo-year
T
o download detailed specifications for these products go to www.fluke.com/tis
p
ecs
Ti Series Industrial Thermal Imagers
The ultimate tools for troubleshooting and maintenance
Find problems faster with
Fl
u
k
e t
h
erma
l
i
magers.
Turn to the hi
g
h performance Fluke
F
lexCam
®
li
ne w
h
en
y
ou nee
d
a
5
inch hi
g
h-contrast LCD and supe
-
r
i
or on-
i
ma
g
er ana
ly
s
i
s capa
bili
t
i
es.
I
ma
g
es stored on a 1 GB compact
flash card can be downloaded to a
c
om
p
uter with included USB cable or
c
ard reader. Offers video out for live
s
harin
g
of thermal ima
g
es. Addi
-
t
i
ona
l
l
enses are ava
il
a
bl
e.
Fl
u
k
e
p
uts powerful technolo
gy
within
y
our reac
h
.
o
p
tional tele
p
hoto len
s
T
he per
f
ect tools to add to your problem solving arsenal. Built
f
or tough work environments, these high-per
f
ormance,
f
ully
radiometric imagers are ideal
f
or troubleshooting electrical sy
s
-
tems, electro-mechanical equipment, process equipment, HVAC/R
e
quipment and others.
E
nhanced problem detection and analysis capabilities with
p
atent-pending IR-Fusio
n
® Technology—only available
f
rom
F
l
u
k
e
O
ptimized for field use in harsh work environments
E
ngineered and tested to withstand a 2 m
(
6.5 ft) drop
Withstands dust and water—tested to an IP 54 ratin
g
I
nnovative protective lens cover protects the lens when
n
o
t in u
se
D
elivers the clear, crisp images needed to
f
ind problems
f
as
t
I
denti
f
y even small temperature di
ff
erences that could
i
ndicate problems with excellent thermal sensitivity
(
NETD
)
E
ven the smallest details become visible with the large,
w
idescreen full color L
C
D display
I
ntuitive, three-button menu is easy to use... simply navigate
w
ith the push o
f
a thum
b
S
ee pa
g
e 44 for IR-Fusion Technolo
g
y—only available from Fluke
.
See pa
g
e 48 for recommended accessories
.
Specifications
Ordering information
Included accessories Models
In-box training DVD, SmartView
®
analysis and reporting software,
2
GB
S
D memor
y
card, multi-function memor
y
card reader, hard carr
y
case,
s
oft carr
y
case, hand strap, two external smart rechar
g
eable batteries, ac
c
harger
/
power supply.*
*Included accessories var
y
b
y
model.
FLK-Ti2
5
9HZ Thermal Ima
g
e
r
FLK-Ti1
0
9HZ
Th
erma
l
I
ma
g
e
r
FLK-Ti
32
9
HZ
I
ndustrial-
C
ommercial Thermal Imager
FLK-Ti32
60
HZ
I
ndustrial-Commercial Thermal Ima
g
er
A
C ada
p
ter, video cable, 1 GB com
p
act flash card, com
p
act flash card
reader and USB cable, P
C
M
C
IA com
p
act flash card ada
p
ter, SmartView
reportin
g
and anal
y
sis software, two rechar
g
eable batter
y
packs, batter
y
c
har
g
er, neck strap, heav
y
dut
y
carr
y
in
g
case and users manual on CD.
FLK-Ti4
0
FT-2
0
I
R FlexCam Thermal Ima
g
er
FLK-Ti45FT-
20
I
R Flex
C
am Thermal Imager
FLK-Ti
50
FT-2
0
I
R FlexCam Thermal Ima
g
er
FLK-Ti
55
FT-2
0
I
R FlexCam Thermal Ima
g
er
H
an
d
s-on tra
i
n
i
n
g
,
W
e
bi
nars, v
i
rtua
l
d
emos an
d
more.
w
ww.fluke.com/titraining
Thi
s too
l
w
ill
h
e
l
p
d
eterm
i
ne t
h
e
return on investment of a Fluke
Th
erma
l
I
mager
.
w
ww.fluke.com
/
ro
i
Th
erma
l
I
mag
i
ng
47
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Th
erma
l
i
mag
i
ng equ
i
pment
so
l
ut
i
on center
These tools can help you find out more
ab
out t
h
erma
l
i
mag
i
ng w
h
et
h
er you
c
urrent
l
y own a t
h
erma
l
i
mager or are
c
ons
id
er
i
ng a purc
h
ase.
w
ww.fluke.com
/
tisolutions
Resources
Specialty models
F
or more in
f
ormation,
g
o to www.fluke.com/thermal_ima
g
in
g
Ti Series Buildings Thermal Imager
s
Optimized for energy audits and moisture detection
Features TIR32 TIR1 TiR
T
emperature measurement range
(not calibrated below -10 °C)
-
20 °C to +150°C
(-4 °F to + 302 °F)
-
20
°
C to +100
°
C
(
-4
°
F to + 212
°
F
)
Temperature measurement accurac
y
± 2 °C or 2 % (at 25°C nominal, whichever is
g
reater) ± 5
°
C or 5 %
(
at 25
°
C nominal,
w
hichever is greater
)
On-screen emissivit
y
correction Yes
O
n-screen reflected back
g
round
tem
p
erature com
p
ensat
i
o
n
Yes
O
n-screen transmission correction Ye
s
Ima
g
e capture frequenc
y
60 Hz or 9 Hz refresh rate dependin
g
on model
D
etector type
320
X
2
4
0
Focal Plane Array,
u
ncooled microbolometer 160 X 120 Focal Plane Arra
y
, uncooled
T
hermal sensitivit
y
(
NETD) ≤ 0.05
°
C at 30
°
C tar
g
et temp.
(
50 mK
)
≤ 0.07
°
C at 30
°
C tar
g
et temp.
(
70 mK
)
≤ 0.1
°
C at 30
°
C tar
g
et temp.
(
100 mK
)
F
ield of view
(
standard lens
)
F
ield of view: 23 ° x 17 °; minimum focus distance: 15 cm (approx. 6 in)
S
patial resolution
(
IFOV
)
1.2
5
mRad
2
.
5
mRa
d
O
p
tional tele
p
hoto infrared lens
Y
e
s
Optional wide-an
g
le infrared lens Yes
S
tandard palette
s
I
ronbow, Blue-Red, Hi
g
h Contrast,
A
m
b
er
,
A
m
b
er
I
nverte
d,
H
ot
M
eta
l,
G
ra
y
scale, Gra
y
scale Inverted
Ironbow, blue-red, hi
g
h contrast,
amber, hot metal,
g
re
y
I
ronbow, blue-red, hi
g
h contrast,
g
re
y
Ultra contrast palettes
I
ronbow Ultra, Blue-Red Ultra,
High
C
ontrast Ultra, Amber Ultra,
Amber Inverted Ultra
,
Hot Metal
Ultra,
G
ra
y
scale Ultra,
G
ra
y
scale
I
nverte
d
Ul
tr
a
I
R Fusio
n
®Yes
C
olor alarms
(
user selectable
)
D
ew point-temperature alarm
Voic
e
a
nn
o
t
a
t
io
n
60
seconds maximum recording time per image;
r
eviewable pla
y
back on ima
g
e
r
S
tora
g
e medium SD Memor
y
Card
(
2 GB memor
y
card will store at least 1200 full
y
radiometric
(
.is2) IR and
linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images,
or 3000
j
pe
g
(
.
j
pe
g
) ima
g
es; transferrable to PC via included multi-format USB card reader
Export file formats w/included
S
m
a
rtVie
w
®
So
ftw
a
re BMP
,
DIP
,
GIF
,
JFIF
,
JPE
,
JPEG
,
JPG
,
PNG
,
TIF
,
and TIFF
Batteries Two Lithium Ion rechar
g
eable
smart batter
y
packs with 5-se
g
-
m
ent
LED
Di
sp
l
ay to s
h
ow c
h
arge
level. Batter
y
li
f
e: 4+ hours;
Batter
y
char
g
e: 2.5 hours to full
ch
arge
Internal rechar
g
eable batter
y
pack
(
included)
B
atter
y
life: 3 to 4 hours
B
attery charge:
2
.5 hours to full charge
A
C batter
y
char
g
in
g
T
wo-ba
y
ac batter
y
char
g
er
(
110 V ac to 220 V ac, 50/60 Hz
)
(
included), or in-imager charging,
a
c mains adapters included
AC adapter
/
charger (110 V ac to 220 V ac, 50
/
60 Hz) (included),
Char
g
es batter
y
while ima
g
er is operatin
g
or turned off,
ac mains adapters included
A
C operation
A
C operation with included power suppl
y
(110 V ac to 220 V ac, 50/60 Hz), ac mains adapters included
E
nc
l
osure rat
i
ng
I
P5
4
Drop tested 2 m
(
6.5 ft
)
W
arrant
y
T
wo-
y
ea
r
T
o download detailed speci
cations
f
or these products go to www.fluke.com/tis
p
ecs
T
he ultimate tools
f
or energy audits, building maintenance, rest
o
-
a
ti
o
n
a
nd remedi
a
ti
o
n.
E
nhanced problem detection and analysis capabilities with
p
atent-pending IR-Fusio
n
®
Technology—only available
f
rom Fluke
O
ptimized for field us
e
Engineered and tested to withstand a 2 m
(
6.5 ft) dro
p
W
ithstands dust and water—tested to an IP 54 rating
Innovative protective lens cover protects the lens when
no
t in u
s
e
Delivers the clear, crisp images needed to
f
ind problems
f
ast
Identi
f
y even small temperature di
ff
erences that could
i
ndicate problems with excellent thermal sensitivity
(
NETD
)
Even the smallest details become visible with the large,
widescreen full color L
C
D displa
y
Intuitive, three-button menu is easy to use... simply navigate
with the push o
f
a thumb
ee pa
g
e 44 for IR-Fusion Technolo
g
y—only available from Fluke
.
See page 48 for recommended accessories.
TiR32
shown
with
opt
i
ona
l
w
id
e an
gl
e
l
en
s
FlexCam
®
Th
erma
l
I
magers
T
he ex
p
erts’ choice
f
or
b
uildin
g
dia
g
nostic
s
The Fluke TiR
3
FT and TiR4FT Thermal
Imagers are
f
or pro
f
essionals demand
-
i
ng the best and most thorough
solutions in building diagnostics appli
-
c
ations. The Fluke TiR-
S
eries
p
rovides
t
he industrys largest LCD to view
o
n-camera images, augmented with
t
he inn
o
v
a
tive IR-Fu
s
i
on
®
Technology
t
o better pinpoint building problems.
IR-Fusion is the overlay o
f
IR and vi
s
-
i
ble images, allowing one to clearly
i
denti
f
y critical points within the
t
hermal image.
Fluke Ti
S
Building
Di
agnost
i
cs
Th
erma
l
I
mag
i
ng
Scanner
The new Fluke TI
S
i
s
t
he top-per
f
orming
i
mager in its price
c
l
ass
a
nd meet
s
the
p
roposed RE
S
NET
i
n
f
rared inspection
s
t
a
nd
a
rd
s
.
1
20
x 1
20
resolution
L
argest display in
p
rice class,
30
%
l
arger than comp
a
-
r
a
ble m
o
del
s
A
ward winning design, built rugged
t
o withstand 2 m
(
6.5 ft) dro
p
Specifications
Ordering information
Included accessories Models
In-box trainin
g
DVD,
S
martView
®
anal
y
sis and reportin
g
so
f
tware,
2
GB SD memor
y
card, multi-function memor
y
card reader, hard carr
y
c
ase, so
f
t carry case, hand strap, two external rechargeable batteries, ac
c
har
g
er/power suppl
y
and users manual.*
*I
nc
l
u
d
e
d
accessor
i
es var
y
by
mo
d
e
l
.
FLK-TiR32 9H
Z
B
u
ildi
n
g
Di
a
g
nost
i
cs
Th
erma
l
I
ma
g
er
FLK-TiR
32
60
H
Z
B
u
ildi
ng
Di
agnost
i
cs
Th
erma
l
I
mager
FLK-TIR1 9H
Z
Thermal Ima
g
e
r
FLK-TIR 9H
Z
Th
erma
l
I
ma
g
e
r
A
C adapter (TiR4FT only), video cable, 1 GB compact flash card, com
-
pact flash card reader and USB cable, PCMCIA compact flash adapter,
SmartView reportin
g
and anal
y
sis software on CD, two rechar
g
eable
b
attery pac
k
s,
b
attery c
h
arger, nec
k
strap,
h
eavy
d
uty carry
i
ng case an
d
u
sers manual on CD.
FLK-TiR3
/
FT-2
0
I
R Flex
C
am BD Thermal Imager
FLK-TiR4
/
FT-2
0
I
R FlexCam BD Thermal Ima
g
er
FLK-TiS 9H
Z
IR
BD
Th
erma
l
I
ma
g
e
r
Th
erma
l
I
mag
i
ng
48
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Thermal imaging resources from Fluke
Everything you need to use a Fluke thermal imager
S
am
p
le a
pp
lications
M
o
i
sture
d
etect
i
on:
A
ccurate
l
y
d
etect
m
o
i
sture
b
e
hi
n
d
i
nter
i
or wa
ll
s,
i
n ce
ili
ngs,
an
d
un
d
er carpets
.
M
o
ld
reme
di
at
i
on:
C
ontrol mold by
revealing undetected sources of moisture
.
Roo
n
g
:
D
etect water-saturate
d
i
nsu
l
at
i
on
in flat-roof s
y
stems to locate dama
g
ed
portions of roofin
g
structure
.
E
ner
g
y au
di
ts: Perform residential and
commercial ener
gy
audits b
y
scannin
g
for
heatin
g
or coolin
g
(
ener
gy
) loss, moisture
invasion, and HVAC
/
R problems
.
If
you currently own a Fluke thermal imager
or are considering a purchase, please visit
the Fluke Thermal Imaging Resource site at
w
ww.fluke.com
/
titools
.
Le
a
rn m
o
re
a
b
o
ut the v
a
lue
of
therm
a
l
imaging and why Fluke thermal imagers
a
nd
S
m
a
rtView
®
sof
tw
a
re
a
re the be
s
t
so
lu
-
tions on the market today.
W
atch a video, take a virtual demo, and
v
iew
o
r d
o
wnl
oa
d
o
ther u
s
e
f
ul in
fo
rm
a
ti
o
n
a
nd t
oo
l
s.
F
ind the thermal ima
g
er that best fits
y
our applicatio
n
G
o to
w
ww.fluke.com
/
selec
t
.
Us
e
o
ur
o
nline product selection guide to
f
ind out
the best Fluke thermal imager
f
or your
application
.
SmartView software dem
o
Product demo
s
Buildin
g
Inspection with a Fluke
thermal ima
g
er—a vide
o
For more in
f
ormation,
g
o to www.fluke.com/thermal_ima
g
in
g
Th
erma
l
I
ma
gi
n
g
F
LK-LENS
/
WIDE
1
T
I-
C
AR-
C
HARGE
R
W
ide-An
g
le In
f
rared Len
s
Thermal Ima
g
er
C
ar
C
har
g
e
r
(
Ti32 and TiR32 only
)
(
all models exce
p
t FlexCam
)
TI-VIS
O
R
T
I-SBP
3
T
hermal Ima
g
er Sun Visor Smart Batter
y
Pac
k
(
all models exce
p
t FlexCam
)
(
Ti32 and TiR32 only)
10
4
5
4
3
T
I-SB
C
C
ar
C
har
g
e
r
B
atter
y
C
har
g
er
(
FlexCam models onl
y)
(
FlexCam models onl
y
)
T
I-SBC
2
10
3
2
32
Charging Bas
e
A
nt
i
-g
l
are
H
oo
d
(Ti32 and TiR32 onl
y)
(FlexCam models onl
y
)
TI-SB
P
T
I-TRIPOD
R
ec
h
argea
bl
e
B
attery
P
ac
k
Ti
T
r
i
po
d
M
ount
i
ng
B
ase
(FlexCam models onl
y)
(
all models except FlexCam)
BOOK
-
ITP
FLK-LENS/TELE1
I
ntro
d
uct
i
on to Telephoto In
f
rare
d
T
hermograph
y
Lens
(
Ti32 an
d
P
r
i
nc
ipl
es
B
oo
k
TiR32 only)
49
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Th
ermometer
s
F
or more in
f
ormation,
g
o to
w
ww.fluke.com/thermometers
Fl
u
ke
6
1 Infrared
Th
erm
o
meter
s
E
as
y
to use one button
op
eration
E
as
y
tar
g
etin
g
with bri
g
ht
l
aser
S
hock-absorbin
g
moldin
g
i
ncreases ru
gg
edness
Two-
y
ear conditional
warrant
y
Tem
p
erature measurement
ran
g
e up to 275 °C (525 °F)
8:1 o
p
tics
A
ccurate to within ± 2 % of readin
g
o
r 2 °C, whichever is
g
reater
Specialty models
Recommended accessories
F
luke 560 Series
I
nfrared Thermometer
s
Fluke 566 and 568 IR and Contact
Thermometer
s
J
ust w
h
en you t
h
oug
h
t a
d
vance
d
IR
temperature
measurement s
h
ou
ld
b
e eas
i
er
!
Wi
t
h
a stra
i
g
h
t
-
f
orward user inter
f
ace and so
f
t-key menus, the
Fluke 566 and 56
8
make even complex measure
-
ments easy. With just a
f
ew pushes o
f
a button
you can easily adjust emissivity, start data log
-
ging, or turn on and o
ff
alarms. With a rugged,
easy-to-use design, the Fluke 566 and 56
8
can stand up to tough industrial, electrical, and
me
c
h
a
ni
ca
l envir
o
nment
s
.
Measure up to 800
°
C (1470
°
F)
Easily access advanced
f
eatures with the so
f
t
-
key buttons and graphical displa
y
Measure smaller objects
f
rom
f
urther away
C
ompatibility with most type-K thermocouple
s
C
onfidently measure more surfaces, with
a
djustable emissivity and built-in materials
ta
bl
e
Log and download measurements
f
or reportin
g
(
56
8)
Two levels o
f
backlight
A
u
dibl
e an
d
v
i
sua
l
a
l
arms a
l
ert you to me
a
-
s
urement
s
o
ut
s
ide
of
s
et limit
s
Min, Max, Avg, and Di
f
f
unction
s
Includes KT
C
bead prob
e
1 % measurement accurac
y
Versatile inter
f
ace with six language
s
Models Fluke 561 Fluke 566 Fluke 568 Fluke 68IS Fluke 62
In
f
rared temperature range
-
40 °C to 535 °C
(
-40 °F to 1022 °F
)
-40 °C to 650 °C
(-40 °F to 1200 °F)
-40 °C to 800 °C
(
-40 °F to 1470 °F
)
-32 °C to 760 °C
(-25 °F to 1400 °F)
-
30 °C to 500 °
C
(
-20 °F to 932 °F
)
A
ccurac
y
greater of ± 1 % or ± 1 °C (2 °F)
g
reater of ± 1 %
o
r ± 1
°
C (2
°
F)
g
reater of ± 1.5 %
or ± 1
°
C (2
°
F
)
Distance to Spot
(
D:S
)
12:1
3
0
:1
50
:1
50
:1
10
:
1
S
ighting
L
aser
p
o
i
n
t
T
y
pical distance to tar
g
et Up to 2.5 m
(
7 ft) Up to 4.5 m
(
15 ft) Up to 7.5 m
(
25 ft
)
U
p to 7.5 m
(
25 ft)
U
p to 2 m
(
6 ft)
P
ro
b
e t
y
p
e
Th
ermocoup
l
e
K
RTD
C
ontact temperature range -40 °C to 550 °C
(
-40 °F to 1022 °F
)
-270 °C to 1372 °C
(
-454 °F to 2501 °F
)
-40 °C to 260 °C
(
-40 °F to 500 °F
)
Number o
f
on-board
m
emory
l
ocat
i
on
s
2
0
99
12
P
C download and software
Y
es
,
wi
t
h
Fl
u
k
e
Vi
e
w
®
Fo
rm
s
S
oft-ke
y
feature menu
n
avi
g
ato
n
Y
e
s
M
in
/
Max
/
Avg
/
Dif
M
in
/
Max
/
Dif Min
/
Max
/
Avg
/
Dif
M
in
/
Max
/
Avg
/
Dif
Ma
x
E
nglish, French,
C
hinese,
Spanish, Portuguese,
G
erman user interfac
e
Y
e
s
M
aterial type adjustment
(
emissivity
)
Hi
/
Med
/
Lo
M
aterial table or 0.1 to 1.00 b
y
0.0
1
0
.1 to 1.00 b
y
0.01 Preset to
0
.9
5
T
wo levels of backli
g
h
t
Ye
s
Hi
g
h
an
d
l
ow a
l
arm
s
Hi
g
h
an
d
l
ow a
l
arm
s
Hi
g
h
an
d
l
ow a
l
arm
s
H
azar
d
ous
l
ocat
i
on
app
rova
l
FM
a
pp
rove
d
i
ntrinsically sa
fe
H
ands-
f
ree lo
gg
in
g
Y
e
s
B
atter
y
2AA
9
V
I
n
cl
u
d
e
d
case
Hard case (exce
p
t
561
/
R and 561
/
P
)
Hard case
S
oft cas
e
Warrant
y
Two-yea
r
Fluke 561 Infrared and
C
ontact Thermometer
The Fluke 561 combines
t
he temperature me
a
-
s
urement
f
un
c
ti
o
n
s
t
hat pro
f
essionals
need f
o
r m
os
t HVA
C
a
nd industrial jobs,
a
ll in
o
ne t
oo
l.
Pipe probe
f
or
superheat and
sub-cooling and
o
ther
co
nt
ac
t
a
nd
a
mbient
me
as
uremen
ts
M
in, Max and Di
f
f
unctions help you
q
uickly identi
f
y problems
S
can large areas or small objects
q
uickly and e
ff
iciently
Specifications
Included accessories Models
U
SB cable
,
FlukeVie
w
®
Forms so
f
tware, thermocouple K-t
y
pe bead probe,
c
arrying case, two AA batteries, users manual, quickstart guide.
F
LUKE-56
8
In
f
rared Thermometer
T
hermocouple K-type bead probe, carrying case, two AA batteries, users
manua
l
an
d
qu
i
c
k
start gu
id
e.
F
LUKE-
566
In
f
rared Thermometer
T
hermocouple K-type pipe probe, carrying case, two AA batteries, users
m
a
nu
al
.
F
LUKE-
561
Infr
a
red Therm
o
meter
9
V battery, instruction sheet.
F
LUKE-
6
1 Infr
a
red Therm
o
meter
Ordering information
8
0
PK-1
0
80
PK-1
8
P
ipe
C
lamp
P
ipe
C
lamp
T
emperature Probe
T
emperature Prob
e
See
page
5
8
S
ee
page
5
4
8
0PK-1
1
80PK-27
Pipe Clamp Probe
I
ndu
s
tri
a
l
S
urf
ace
S
e
e
pa
g
e 5
8
T
emperature
P
ro
b
e
Se
e
page
58
50
Specialty models
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
For more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/
th
e
rm
o
m
e
t
e
r
s
Th
ermometer
s
Recommended kits
F
luke 570 Series Infrared
T
hermometers
The Fluke 57
2
and 574 ar
e
i
deal diagnostic tools
f
or
maintenance pro
f
essio
n
-
a
ls requiring accurate
t
emperature readings at
a
ll di
s
t
a
n
c
e
s
. Predi
c
tive
maintenance pro
f
essio
n
-
a
ls requiring analysis
a
nd d
oc
ument
a
ti
o
n u
s
e
t
he 574 model, with
1
00
-point data lo
g
-
g
ing with the included
so
f
tware
f
or graphing and
a
nalysis
f
or
f
ollow-up reporting and
doc
ument
a
ti
o
n.
Backlit display
f
or poorly lit area
s
Displays last ten temperature
reading
s
E
nhanced optics
(
distance to spot
ratio up to
60
:1
)
I
ntrinsically safe model on page 39.
F
luke 62 Mini Infrared Thermomete
r
Non-contact temperature measurement
T
he Fluke
62
Mini non-contact thermometer is the perfect
introduction to infrared
(
IR) thermometers for the professional.
W
ith the best accuracy in its class, the Fluke
62
mini offers
quick and reliable sur
f
ace temperature readings. This compact
and portable tool enables pro
f
essionals to diagnose heating and
v
entilation problems and monitor the temperature o
f
electrical
m
otors and electrical panels without contact.
Accurate to within ± 1.5 % of reading or ± 1.5
°
C
T
emperature measurement range up to 500
°
C (932
°
F
)
10
:1 optics
B
acklit display
f
or poorly lit areas
Laser sighting
D
ual display shows current and max measurements
s
imultaneousl
y
6
2-411D Kit
Fluke
62
Mini I
R
Thermometer
Fluke 411D Las
e
D
istance Meter
S
oft
p
ouch for
e
ac
h m
o
del
All m
o
del
s
o
ffer
:
Laboratory accuracy: ± (0.05 % + 0.3
°
C
)
Large backlit dual display
Min/Max/Av
g
Electronic o
ff
set
f
unction maximizes overall accurac
y
S
upports a wide range of thermocouple types
Temperatures displayed in
°
C,
°
F, or Kelvin (K
)
Powerful data lo
gg
in
g
capabilities
The Fluke 5
3
II B and 54 II B can log up to 5
00
points of data to
internal memory.
User-adjustable recording intervals
Real-time clock ca
p
tures the exact event tim
e
Recall
f
unction lets logged data be easily reviewed
Download data to o
p
tional FlukeVie
w
®
P
C
so
ftw
a
r
e
Features 54 II B 53 II B 52 51
T
hermocouple t
y
pes K
,
J
,
T
,
E
,
N
,
R
,
SK
,
J
,
T
,
E
,
N
,
R
,
SK
,
J
,
T
,E
K
,
J
,
T
,E
Number o
f
in
p
uts Dua
l
Sin
g
le
D
ual
S
in
g
le
Time stamp Time o
f
da
y
Time o
f
da
y
F
luke 50 Series II Thermometer
s
Lab accuracy in a eld thermometer
Features
Ordering information
Included accessories Models
S
torage pouch and instruction sheet.
F
LUKE-
62
M
ini Infr
a
red Therm
o
meter
F
LUKE-62
/
T+PRO
/
1AC
IR
Th
ermometer,
El
ectr
i
ca
l
T
ester an
d
V
o
l
tage
D
etector
Ki
t
F
LUKE-T5-600
/
62
/
1AC
IR
Th
ermometer,
El
ectr
i
ca
l
T
ester an
d
V
o
l
tage
D
etector
Ki
t
F
LUKE-62
/
322
/
1AC
I
R Thermometer, Clamp Meter and Voltage Detector Kit
F
LUKE-411D
/
62
I
R Therm
o
meter
a
nd Di
s
t
a
n
c
e L
as
er Meter Kit
Bead thermocou
p
le
(
s), batteries,
o
verv
i
ew m
a
nu
al
a
n
d
i
n
s
tru
c
t
io
n
al
g
uide on
C
D.
F
LUKE-
5
4-2-B
D
atalogging Thermometer, Dual Input
F
LUKE-
5
3-2-B
D
atalogging Thermometer,
S
ingle Input
F
LUKE-
5
2-2
D
igital Thermometer, Dual Input
F
LUKE-
5
1-2
D
igital Thermometer, Single Input
Thermocou
p
le K
p
robe
(
574),
p
ower
supply
(
574), RS-232 data cable
(
574),
d
ata
g
rap
hi
n
g
, stora
g
e an
d
ana
ly
s
i
s
software on CD (574), hard case, two
AA batteries, operator’s guide on CD.
F
LUKE-574-
C
F Precision Infrared Thermometer w/Lo
gg
in
g
SW Close Focus
F
LUKE-57
4
Precision Infrared Thermometer w/Lo
gg
in
g
SW
F
LUKE-57
2
-
C
F Precision Infrared Thermometer with
C
lose Focus Option
F
LUKE-57
2
Precision In
f
rared Thermometer
62/T+PRO/1AC-II
6
2 Non-contact
Th
erm
o
meter
T+R
O
Electrical Te
s
1
A
C
-II Volta
g
e Det
e
C
arr
y
in
g
case
T5-600/62/1AC-II Kit
Fluke
62
Mini IR
Thermometer
Fluke T5-600 Vo
l
E
lectrical Tester
1
AC-II Voltage
D
ete
c
t
or
Carrying case
62/322/1AC-II Ki
t
Fluke
62
Mini IR
Th
ermometer
Fluke
322
C
lamp M
e
1
A
C
-II Volta
g
e Det
e
Test lead
s
C
arr
y
in
g
case
51
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Recommended accessories
Applications
T
hermometers
/
IR-Windows
F
or more in
f
ormation,
g
o to www.
f
luke.com
H
awk IR C-Range IR-Windows
Got switchgear?
U
se arc-res
i
stant
IR
Wi
n
d
ows w
i
t
h
Q
uadraban
d
optic technolo
gy
I
n
f
rared windows mount into panel doors and covers
f
or switch
-
g
ear, trans
f
ormers, buss bars and other live electrical equipment,
allowing thermal, ultraviolet, visual and
f
usion technologies to be
used without exposing personnel to live equipment
.
R
educe the risk associated with electrical thermograph
y
R
educe labor required to inspect your switchgear
f
rom three
h
e
a
d
s
t
o
o
n
e
S
tay safety compliant with
N
FPA 7
0
E and other safety
p
rotocols and leave the panels
c
l
os
e
d
E
xtend the li
f
e o
f
your equip
-
m
ent with more
f
requent IR
scans
E
asy to instal
l
D
urable enough to withstand
e
xtreme outdoor conditions yet
p
ractical
f
or indoor applications
as
wel
l
Temperature 5616-12 5610-9
-
200 °C
(
-328 °F
)
0
.
0
14
0 °C (32 °F)
0
.
0
2
1
0
.
00
9
1
00
°
C (212
°
F)
0
.
0
2
7
0
.
0
3
0
3
00
°
C (572
°
F)
0
.
0
4
0
420
°
C (788
°
F)
0
.
0
5
0
T
he 1523
/
24 Reference Thermometers from the Hart Scientific Division
m
easure, graph, and record PRTs, thermocouples, and thermistors. You
c
an measure up to
0
.
3
seconds per sample and plot and scale trends
i
n real time. Both thermometers have memory for up to
2
5 readings
w
ith statistics. The 15
2
4 has
2
inputs with data logging memory for
1
5,
000
measurements with date and time stamps.
T
emperature probes are required
f
or measurements and are sold
s
eparately as accessories. The universal thermocouple adapter is
c
on
f
igurable
f
or di
ff
erent thermocouple types and has memory
f
or
c
alibration coefficients. Free I
O
Toolkit software is included for upda
t
-
i
ng password protected calibration information stored in 1523/1524
p
robe connectors.
A
ccuracies of selected readout/probe combinations including read
-
o
ut accuracy probe calibration and probe drift (±
°
C)
.
E
quivalent temperature readout accuracy for measuring type K thermocouples is ± 0.24
°
C (± 0.43
°
F) from 0
°
C to 1370
°
C
(32 °F to 2498 °F) and ± 0.61°C (± 1.10 °F) from –200 °C to 0 °C (–328 °F to 32 °F). Additional errors for thermocouple accuracy
or ca
lib
rat
i
on must
b
e a
dd
e
d
separate
ly
.
Features
Ordering information
Included accessories Models
IR
Wi
n
d
ows are supp
li
e
d
comp
l
ete,
a
ssembled and read
y
f
or installation.
I
n addition to the IR Window each
carton contains an installation CD,
self-adhesive drillin
g
template, securit
y
a
ccess ke
y
, warrant
y
statement.
F
LK-
050
-CLKT 50 mm (2 in) C-Range IR Window, Kwik Twist
F
LK-
0
7
5
-CLKT
7
5 mm (3 in) C-Range IR Window, Kwik Twist
F
LK-1
00
-CLKT
1
00 mm
(
4 in) C-Range IR Window, Kwik Twist
F
LK-
0
7
5
-CLKTO
7
5 mm
(
3 in) C-Range IR Window, Kwik Twist
1
2 V dc universal power supply,
R
S-
232
cable
,
NIST traceable
calibration certi
f
icate
,
technical manual
a
nd 9940 I/O ToolKit software on CD,
t
h
ree
AA
b
atter
i
es, users
g
u
id
e.
F
LUKE-1
5
24 Thermometer Readout (2 inputs)
F
LUKE-1
5
23 Thermometer Readout
(
1 in
p
ut)
TPAK, 2373-LTC, carrying case.
F
LUKE-1
5
24-P1
15
24 Bundled with
56
1
6
PRT
F
LUKE-1
5
23-P1
15
23 Bundled with
56
1
6
PRT
Fluke
CLKT
Fluke
CLKTO
F
luke 1524/1523 Reference
Thermometers
56
1
6
-12-
P
56
10-9-P
P
re
cisio
n
PRT
P
re
cisio
n
Th
erm
is
t
o
r
30
5 mm x
6
.
3
5 m
m
229
mm x
3
.
2
m
m
(
12 in x .25 in) (9 in x 1/8 in
)
2
3
7
3
-LT
C
FLK8
0
K1
S
mart connecto
r
80PK-1 T
y
pe K
w
ith universa
l
P
robe and ada
p
te
r
TC ada
p
te
r
(
2373-LTC
)
TPAK
M
agnet
i
c
M
eter
H
ange
r
S
e
e
p
a
ge
62
Fluke 1524
/
1523
52
C
heck price and availabilit
y
at
C
heck price and availabilit
y
at
www.fl
u
k
e
.
co
m
/
wt
b
www.fl
u
k
e
.
co
m
/
wt
b
Resources
Software
Application tips
F
or more in
f
ormation,
g
o to
w
ww.fl
u
k
e
.
co
m
/
vi
b
r
a
ti
o
n
Vib
rat
i
on
G
et answers now!
T
he Fluke
8
10 Vibration Tester is the
m
ost advanced troubleshooting tool for
m
ec
h
an
i
ca
l
ma
i
ntenance teams w
h
o
n
eed an answer NOW. It is a unique new
kind of troubleshooting tool, engineered
to
d
etect an
d
eva
l
uate t
h
e most common
m
ec
h
an
i
ca
l
pro
bl
ems.
T
he Fluke
8
10 Vibration Tester uses a
si
mp
l
e step-
b
y-step process to report on
m
achine faults the first time measur
e
-
m
ents are ta
k
en, w
i
t
h
out pr
i
or mac
hi
ne
hi
story
.
Fl
u
k
e 810 V
ib
rat
i
on Tester
Take a vibration expert along
Sim
p
le 3 ste
p
p
roces
s
T
he Fluke
8
10 helps you locate and diagnose common mechanical problems and
p
r
i
or
i
t
i
ze repa
i
r act
i
ons
i
n t
h
ree s
i
mp
l
e steps
:
V
iewer PC Softwar
e
Store and track your data
Generate diagnostic reports
a
nd track the severity of your
mac
hi
ne
s con
di
t
i
on
Import and store JPEG and Fluke
IS
2
thermal images
D
ia
g
nostic speci
f
ications
Anal
y
sis fo
r
M
otors, fans, blowers, belts and chain drives,
g
earboxes, couplin
g
s, centrifu
g
al pumps, piston
pumps, slidin
g
vane pumps, propeller pumps, screw pumps, rotar
y
thread/
g
ear/lobe pumps, piston
c
ompressors, centri
f
ugal compressors, screw compressors, closed coupled machines, spindle
s
Machine rotational speed range 200 r
p
m to 12000 r
p
m
Dia
g
nosis details Plain-text dia
g
nosis, fault severit
y
(
sli
g
ht, moderate, serious, extreme), repair details, cited
p
eaks, s
p
ectra
Tester s
p
ecifications
IP ratin
g
I
P
5
4
A
/
D converter 4 channel
,
24 bit
Dynamic rang
e
1
2
8
dB
F
FT resolutio
n
8
00 lines
B
atter
y
Lithium-ion, rechar
g
eable,
8
hours operatin
g
life
O
nboard stora
g
e capacit
y
2
G
B internal micro SD car
d
W
arrant
y
Three-
y
ears (tester), One-
y
ear (sensor and tachometer)
Sensor specifications
S
ensor t
y
p
e
Tri-axial accelerometer , 100 mV
/g
(± 5 %, 25 °C)
Tachometer speci
f
ications
T
ac
h
ometer t
y
p
e
L
as
er Di
o
de
C
l
ass
2
B
rea
k
t
h
rou
gh
di
a
g
nost
i
c
tec
h
no
l
og
y
The Fluke
8
10s dia
g
nostic technolo
gy
c
ombines powerful al
g
orithms with a
d
atabase of real-world measurement
experience, makin
g
the Fluke
8
10 the
most advanced troubleshootin
g
tool for
mec
h
an
i
ca
l
ma
i
ntenance teams.
A
na
l
yze most common equ
i
pment
:
M
otor
s
F
ans an
d
bl
ower
s
B
e
l
t an
d
c
h
a
i
n
d
r
i
ve
s
Gearboxes
P
um
ps
Com
p
ressors
Sp
indles
D
etect the most common causes o
f
mechanical
f
ailure:
B
ear
i
n
g
pro
bl
ems
Mi
sa
lig
nmen
t
U
n
b
a
l
anc
e
L
oosenes
s
Specifications
Ordering information
Included accessories Models
Tri-axial accelerometer, ma
g
net mount, mountin
g
pad kit with adhesive, quick-
disconnect accelerometer cable, laser tachometer with storage pouch, battery
p
ack with cable and adapters, shoulder strap, adjustable hand strap, Viewer PC
software, mini USB to USB cable, carr
y
in
g
case, trainin
g
DVD,
g
ettin
g
started
g
uide, quick re
f
erence
g
uide, users manual on DVD.
F
LUKE-81
0
FLUKE-810 Vibration Tester
Interactive, self-
paced trainin
g
o
n DVD
L
e
a
rn m
o
re
a
b
o
ut
t
he b
as
i
cs
of
vibr
a
ti
o
n
a
nd h
o
w
t
o
f
ully utilize the
f
e
a
ture
s
a
nd
f
un
c
-
t
ionality o
f
the
F
luke 810. Fluke has partnered with
M
obius Institute, an industry leader
i
n vibration training, to develop an
i
nteractive training DVD included with
each Fluke 810
.
Us
e the Fl
u
ke
8
1
0
t
o
:
E
asily determine the root cause, location and severity o
f
common mechanical
f
ault
s
Eff
iciently prioritize and plan equipment repair or replacemen
t
Eff
ectively deploy maintenance resources at the point o
f
greatest impact
1.
S
etup:
Vib
rat
i
on test
i
ng
h
as never
b
een eas
i
e
r
The Fluke
8
10 asks for
basic machine informa
-
ti
on you a
l
rea
d
y
k
now,
lik
e
RPM
an
d
h
orse
-
power. Its onboard Info
f
eature gives you field
t
ips for setting up and
t
a
ki
ng measurements
lik
e a pro.
2. Measure:
The
Fluke
8
10 fits easily into
your ma
i
ntenance
r
out
i
ne.
U
se
i
t to qu
i
c
kl
y
trou
bl
es
h
oot pro
bl
ems
or mon
i
tor mac
hi
ne
con
di
t
i
on.
3
. Diagnose:
Fi
x
i
t r
i
g
h
t
the first time: With the
p
ress of a button, the
F
luke
8
10 identifies the
root cause,
i
ts
l
ocat
i
on,
an
d
t
h
e pro
bl
em
s
s
ever
i
ty
.
Accessories as tough
as your meter
TPAK Meter Hanger—
hang your meter from
magnetic surfaces and
free both hands
(see p. 62)
TL175 TwistGuard Test
Leads—get two category
ratings with one set of
test leads and a wire that
changes color when the
leads need to be replaced
(see p. 57)
AC285 SureGrip
Alligator Clips—SureGrip
rubber provides a
reliable, ergonomic
grip in slippery hands
(see p. 57)
When your job depends on your meter... your
meter depends on Fluke Genuine Accessories
53
54 For more information, go to www.fluke.com/accessories
Accessories54
Soft cases
C12A Meter Case
Made of vinyl
Dimensions (HxWxD): 172 x 128 x 38 mm
(6.8 x 5 x 1.5 in)
C75 Accessory Case
Made of vinyl
Dimensions (HxWxD): 179 x 103 x 26 mm
(7 x 4 x 1 in)
C50 Meter Case
Made of vinyl
Dimensions (HxWxD): 192 x 90 x 38 mm
(7.56 x 3.5 x 1.5 in)
C25 Large Soft Case for DMMs
Made of vinyl
Dimensions (HxWxD): 218 x 128 x 64 mm
(8.6 x 5 x 2.52 in)
C90 Soft Case for DMMs
Made of vinyl
Dimensions (HxWxD): 205 x 90 x 72 mm
(8 x 3.5 x 2.8 in)
C35 Soft Carrying Case
Made of durable polyester 600D
Dimensions (HxWxD): 220 x 140 x
65 mm (8.7 x 5.5 x 2.6 in)
C23 Soft Carrying Case
Made of durable vinyl
Dimensions (HxWxD): 225 x 95 x 58 mm
(8.9 x 3.75 x 2.3 in)
C280 Soft Case
Made of durable polyester 600D
Dimensions (HxWxD): 230 x 185 x
65 mm (9 x 7.3 x 2.6 in)
C115 Soft Carrying Case
Made of durable polyester 600D
Dimensions (HxWxD): 240 x 205 x
75 mm (9.5 x 8 x 3 in)
C116 Soft Carrying Case
Made of durable polyester 600D
Dimensions (HxWxD): 240 x 230 x
65 mm (9.5 x 9 x 2.6 in)
C570 Soft Case
Made of vinyl
Dimensions (HxWxD): 240 x 89 to 170 x
56 mm (9.5 x 3.5 to 6.7 x 2.2 in)
C781 Meter Case
Made of durable polyester 600D
Dimensions (HxWxD): 269 x 141 x 90 mm
(10.6 x 5.6 x 3.5 in)
C33 Soft Carrying Case
Made of vinyl
Dimensions (HxWxD): 280 x 115 x 55 mm
(11 x 4.5 x 2.2 in)
C789 Meter and Accessory Case
Made of durable polyester 600D
Dimensions (HxWxD): 308 x 256 x
77 mm (12 x 10 x 3 in)
C43 Soft Carrying Case
Made of durable polyester 600D
Dimensions (HxWxD): 318 x 230 x
90 mm (12.5 x 9.1 x 3.5 in)
C550 Tool Bag
Made of ballistic cloth with heavy-duty
hardware
Dimensions (HxWxD): 333 x 513 x
231 mm (13 x 20.2 x 9.1 in)
C345 Soft Case
Made of durable polyester 600D
Dimensions (HxWxD): 360 x 200 x
240 mm (14 x 8 x 9.5 in)
Hard cases
CXT Series Extreme Cases
Models CXT80, CXT170, and CXT280 for
various meter compatibility
Unbreakable, watertight, airtight, chemi-
cal resistant and corrosion proof
C800 Meter and Accessory Case
Dimensions (HxWxD): 230 x 385 x
115 mm (9 x 15 x 4.5 in)
C20 Hard Case
Made of polyprophylene
Dimensions (HxWxD): 256 x 154 x
106 mm (10 x 6.1 x 4.2 in)
C101 Hard Case
Exterior dimensions (HxWxD): 305 x
360 x 105 mm (12 x 14.2 x 4.1 in)
Interior dimensions (HxWxD): 230 x
290 x 65 mm (9 x 11.5 x 2.5 in)
C100 Universal Carrying Case
Dimensions (HxWxD): 397 x 346 x
122 mm (15.7 x 13.6 x 4.8 in)
C1600 Gear Box
Includes five hook and loop straps to
wrap cords and test leads
Dimensions (HxWxD): 260 x 390 x
200 mm (10 x 15 x 7.8 in)
Leather cases
C520A Leather Tester Case
Dimensions (HxWxD): 256 x 154 x
106 mm (10 x 6 x 4 in)
C510 Leather Meter Case
Dimensions (HxWxD): 287 x 179 x
106 mm (11 x 7 x 4 in)
Holsters
C10 Meter Holster
Compatible with Fluke 10 Series
Multimeters
Dimensions (HxWxD): 154 x 77 x 45 mm
(6 x 3 x 1.8 in)
H80M Protective Holster
Includes a hanging magnet, general pur-
pose hanger, and hook and loop straps
Dimensions (HxWxD): 190 x 95 x 43 mm
(7.5 x 3.7 x 1.7 in)
H5 Electrical Tester Holster
Dimensions (HxWxD): 192 x 90 x 38 mm
(7.5 x 3.5 x 1.5 in)
H3 Clamp Meter Holster
Dimensions (HxWxD): 231 x 90 x 64 mm
(9 x 3.5 x 2.5 in)
H6 IR Thermometer Holster
Dimensions (HxWxD): 302 x 178 x 57 mm
(11.9 x 7 x 2 in)
Fluke cases and holsters
A premium meter deserves a premium case
Selection
Guide
10/11/12/12B
110/111/112
114/115/116/117
20/70 Series
27 II/28 II/27
175/177/179
80 Series III/83V
87V/89 IV
233
287/289/187/189
39/41B
43B
120 Series
50S/50D
50 Series II
63/66/68
321/322
330 Series
705/707
712/713
714/715/716/717
718
725/726
741/743/744
787/789
T3/T5
1503/1507/1577/1587
C280 • ••••• •• • ••••• •
C345 The perfect case for carrying a wide range of Fluke handheld test tools and accessories
CXT80 ••
18x ••
CXT170 •• • •
CXT280 28x
C50 ••• •
C520A
C550/C1600 The C550 and C1600 are large enough to hold accessories and multiple test tools
C12A •••
C25 •••••• •• ••••
C33 •• •
C35 •••
C43 •••••• ••
C90 ••• • ••
C115/C116 •••••••• •••• • •
C125 ••
C781 • •• •••
789
C789 ••• • ••
C101 ••••••••• ••••••••••• •••
C510 ••787
C100 ••• 787
C800 •• 787
C35 C550 CXT80 C510 H5
55
A
cce
ss
or
i
e
s
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/accesso
ri
es
T
LK289 Industrial Master Test
Lead Set and
C
ase
D
esigned
f
or electrical and electronics test
i
n to
d
ay
s
i
n
d
ustr
i
a
l
env
i
ronment
S
ure
G
rip
a
lli
gator c
li
ps, gra
bb
ers,
h
oo
k
c
li
ps an
d
i
n
d
ustr
i
a
l
test pro
b
e
s
f
or dependable contact with a variety o
f
test po
i
nts
Magnetic hanger
f
or suspension o
f
your
DMM
T
emperature a
d
apter w
i
t
h
K
-
T
ype
thermocouple
f
or direct temperature
m
easurement with your DMM’s
TLK-225 SureGri
p
M
aster
Accessory Ki
t
Pl
unger sty
l
e a
lli
gator c
li
ps
Pl
unger sty
l
e
h
oo
k
c
li
p
s
Pl
unger sty
l
e p
i
ncer c
li
p
s
L
arge
j
aw a
lli
gator c
li
ps
S
harp test probe
s
Ri
g
h
t to stra
i
g
h
t test
l
ea
ds
6
-pocket storage pouch, keeps the
e
nt
i
re set toget
h
er
Fl
u
k
e accessor
y
sets an
d
ki
ts
Save money on our most popular accessories
TLK-
220
SureGrip
Accessor
y
Kit with Meter Carry Case
Pl
un
g
er st
yl
e a
llig
ator c
li
ps
L
ar
g
e
j
aw a
llig
ator c
li
ps
S
har
p
test
p
robe
s
Righ
t to stra
igh
t test
l
ea
ds
Zi
ppere
d
v
i
n
yl
carr
y
case w
i
t
h
mov
e
-
a
bl
e
di
v
id
er
H
o
ld
s
l
ar
g
e
DMM
s
T5 Tester
S
tarter Ki
t
G
etting started kit for electricians who
a
l
rea
d
y own a
Fl
u
k
e
T5
T
ester.
T
est probe
s
L
arge jaw alligator clips
Z
ippered so
f
t case
TL220 Industrial Test Lead Se
t
S
tarter kit for industrial applications
T
P
220
has round, stainless steel tip
Includes 1 pair: A
C220
, TP
220
, TL
222
C
AT III 1
000
V
,
C
AT IV
600
V
,
1
0
A
T
L223 Electrical Te
s
t Lead Set
S
tarter kit for electrical application
s
T
P1 h
as
f
l
a
t bl
a
de
s
fo
r w
a
ll
soc
ket
s
I
ncludes 1 pair: A
C220
, TP1, TL
22
4
C
AT III 1
000
V,
C
AT IV
600
V, 1
0
A
TLK287 Electronics Master Test
L
ead Set
T
he per
f
ect test lead kit
f
or todays ele
c
-
tron
i
cs test an
d
d
es
i
gn
P
rec
i
s
i
on e
l
ectron
i
c pro
b
es w
i
t
h
mu
l
t
i
p
l
e
s
pr
i
ng-
l
oa
d
e
d
s
h
arp t
i
ps to max
i
m
i
ze
c
ontact with
S
MD test point
s
M
icro-grabbers and leads to enable
f
ine
S
MD te
st
M
o
d
u
l
ar m
i
n
i
-a
lli
gator c
li
ps, gra
bb
ers,
l
eads, probes, and couplers
f
or virtually
e
very e
l
ectron
i
cs nee
d
Selection
Guide
10
/
110 Serie
s
114/115/116/117
20
/
70 Serie
s
27 II/28 II/2
7
175
/
17
7
17
9
8
0
Serie
s
87V
/
233
287
/
289
/
187
/
18
9
3
9
/
41B
/
43B
90
Serie
s
1
20
Series
190 Series
3
21
/
32
2
3
30 Series
705
/
70
7
715
716
/
71
7
71
8
725/726
741
/
74
3
74
4
787
/
789
1
58
7
1577
TLK287
TLK289
1
1
6
TL220
TL223
TL225
TL238
TL80A
TL81A
TL71
TL76
80K-8, 80K-15,
80K-40
dc
on
ly
dc
o
n
l
y
F
or more in
f
ormation,
g
o to
w
ww.
f
luke.com/accessories
A
cce
ss
or
i
e
s
5
6
56
Fl
u
k
e test
l
ea
d
s,
p
ro
b
es an
d
c
lips
The best leads for all your measurement needs
For electronic applications For automotive application
s
TL80A
B
a
si
c
El
ec
t
r
o
n
i
c
T
e
st
L
ea
d
S
e
t
6
piece set with zippered case
Probes, alligator clips and tip extenders
f
or electronic applications
C
AT II
300
V
TL
9
1
0
Electr
o
nic
Te
s
t Pr
ob
e
s
with
Replacement Tip
s
S
mall profile provides
a
ccessibility
C
omes with 5 sets o
f
replaceable tip
s
Replacement tips:
TP
9
1
2
C
AT III 1
000
V,
3
A
TP
80
Electr
o
nic Te
s
t
Pr
ob
e
s
Tapered tip ideal
f
or
probing electronic com
-
ponents or boards
Removable guard for I
C
probin
g
C
AT III 1
000
V, 1
0
A
TP
920
Te
s
t Pr
ob
e
A
dapter Ki
t
I
C
test tip adapters,
extended tips, medium
a
lligator clips
f
it over
TL71 and TL75 test
l
e
a
d
s
et
s
I
C
test tip Adapter,
3
A
E
xtended probe tip,
3
A
M
ed. alligator clip, 5 A
C
AT II
300
V
TL4
0
Retracta
b
le Pr
ob
e
A
ssembl
y
Retractable, insulated
sharp probe tip
C
AT III
300
V,
3
A
TL2
6
A Telec
o
m Te
s
t
L
ead
S
et
5
-way multipoint test
c
lips
f
or telecommun
i
-
c
ations applications
F
lexible
s
ili
co
ne in
s
u
-
la
ted le
a
d
s
a
re he
a
t
a
nd
co
ld re
s
i
s
t
a
nt
CAT I 30 V, 8
A
TP81 and TP82
Stainless steel probe
p
i
erces
i
nsu
l
at
i
on
on 14
,
16 and
1
8
g
au
g
e wire
D
es
ig
n prov
id
es comp
l
ete
insulation while workin
g
on fuel
i
n
j
ectors or sensors
TP
8
1 for use with modular test leads
(
Fluke TL224)
TP
8
2 slips over probe tips
(
Fluke TL71)
Rated to
60
V d
c
TP88 Rigid
Back
p
robe Pin
S
e
t
2
inch lon
g
pins
pass
b
etween t
h
e
weat
h
er pac
k
sea
l
a
U
se w
i
t
h
Fl
u
k
e
TL71
l
ea
d
set
s
Rated to
60
V d
c
T
LK
28
1 A
u
t
o
m
o
tive Te
s
t Lead Kit
I
nsulation piercing probe
s
S
uregrip silicone test leads
S
uregrip test probe
s
S
uregrip plunger style alligator clips
S
uregrip alligator clip
s
C
arrying case
T
LK
282
Del
u
xe A
u
t
o
m
o
tive Te
s
t Lead Ki
t
I
nsulation piercing probe
s
S
et of five automotive back probe pin
s
S
uregrip silicone test leads
S
uregrip test probe
s
S
uregrip plunger style alligator clips
S
uregrip alligator clip
s
S
uregrip hook clips
C
arrying case
80K-6, 80K-15, 80K-40 Hi
g
h Volta
g
e Probe
s
Allows a di
g
ital multimeter to measure up
t
o 6,000 volts
p
eak, 15,000 volts
p
eak and
4
0,000 volts peak respectivel
y
1000:1 division ratio out
p
ut when connected
t
o 1
0
M multimeter
Ground cli
p
include
d
Intended for low ener
gy
applications that are
r
eferenced to
g
roun
d
80K-15 (not available in Euro
p
e
)
Hi
g
h
-vo
l
tage pro
b
e
s
TP4
0
A
u
t
o
m
o
tive
Back Pr
ob
e Pin Set
S
et of five 1.5 inch
pins
Rated to
60
V dc
Provide an easy
connection past
weather pack seals to
co
nne
c
t
o
r
co
ndu
c
t
o
r
s
Use with Fluke TL71 or TL75 test
l
e
a
d
s
et
s
TL
82
A
u
t
o
m
o
tive
Pin & S
o
cket
Adapter Set
Co
lle
c
ti
o
n
o
f m
a
le
a
nd
f
em
a
le
a
dapters allows
you to make
f
irm
connection to
p
in
a
nd
soc
ket
co
nne
ct
Adapters with flexible tips come in the
f
ollowing sizes:
22
,
20
, 1
6
and 1
2
Rated to
60
V dc
57
A
cce
ss
or
i
e
s
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/accesso
ri
es
AC28
3
SureGrip
Pincer Clips
4.5 in.
f
lexible, insula
t
N
ickel plated pincers
o
t
o .
20
in
.
C
AT III 1
000
V,
C
AT IV
600
V, 1
A
AC28
5 SureGri
p
Alli
g
ator
C
lips
Multi-purpose tooth pattern
g
rips anything
f
rom
f
ine gauge
w
ire to a 3
/
4 in. nu
t
N
ickel-plated steel jaws
C
AT III 1
000
V,
C
AT IV
600
V, 1
0
A
F
luke SureGri
p
accessor
i
es
As tough as your meter
F
TP Sure
G
ri
p
F
us
ed
T
e
s
t Pr
ob
e
s
B
uilt-in
f
u
s
e
s
fo
r
added
p
rotectio
n
2 mm thre
a
ded
p
robe ti
p
s include
r
em
o
v
a
ble
4
mm
lantern-st
y
le sprin
g
contacts
Removable GS38 insulated IC ca
p
s for
probin
g
closel
y
spaced lead
s
C
AT III 1000 V, CAT IV 600 V, 10
A
T
P1, TP
2
, TP4 and
T
P
3
8 Slim Reach
Te
s
t
P
r
ob
e
s
S
lender
p
robe bodies
f
or probin
g
closel
y
sp
aced or recessed
p
oints
T
P1 h
as
a
f
l
a
t bl
a
d
e
T
P2 h
as
2 mm di
a
m
-
e
ter ti
p
T
P
4
h
as
4
mm di
am
-
e
ter ti
p
T
P3
8
has stainless
s
teel insulated
p
robe
to hel
p
lessen the risk
o
f
arc
f
lash ex
p
losio
n
C
AT III 1000 V, 10 A, CAT IV 600 V, 10
A
T
P
220
SureGri
p
Ind
us
trial Te
s
t Pr
ob
e
s
S
har
p
, 1/2 inch stain
-
l
ess steel ti
p
p
rovides
reli
a
ble
co
nt
ac
t
F
lexible
f
in
g
er barrier
i
mproves
g
ri
p
CAT III 1000 V, 10 A,
CAT IV 600 V, 10 A
FTPL Sure
G
ri
p
F
us
ed
Te
s
t Pr
ob
e
s
with Lead
s
F
TP Fu
s
ed Te
s
t Pr
o
be
s
w
ith built-in
f
u
s
e
s
fo
r
added
p
rotection
T
L224
S
ili
co
ne In
s
u
-
la
ted Te
s
t Le
a
d
s
CAT III 1000 V, CAT IV
6
00 V, 10 A
TL
22
1 SureGri
p
S
ilic
o
ne Te
s
t Lead
E
xten
s
i
o
n Kit
S
u
p
erior strain relief
I
ncludes two ada
p
ters
to extend leads 1.
5
m
C
AT III 1000 V, 10 A,
C
AT IV 600 V, 10 A
T
L
222
SureGri
p
S
ilic
o
ne In
su
lated
T
e
s
t Lead
s
S
u
p
erior strain relie
f
Re
co
mmended
fo
r u
s
e
w
ith AC220, AC280,
AC283 test cli
ps
C
AT III 1000 V, 10 A,
C
AT IV 600 V, 10 A
T
L
22
4 SureGri
p
S
ilic
o
ne In
su
lated
T
e
s
t Lead
s
S
u
p
erior strain relief
1
.
5
m silicone-insu
-
l
a
ted wire re
s
i
s
t
s
h
e
a
t
a
nd
co
ld
C
AT III 1000 V, 10 A,
C
AT IV 600 V, 10 A
S
ure
G
rip accessories provide a reliable grip in slippery hands.
Rubber-overmolded sur
f
aces and
f
inger-hugging curves give the
u
ser a com
f
ortable, steady hold on the accessory so they can
f
ocus on making an accurate measurement
.
M
o
d
u
l
ar test
l
ea
d
s an
d
test
p
ro
b
es (use test
p
robes with test leads)
M
o
d
u
l
ar c
lip
s (use with test leads, includes one red, one black
)
The new standard for safer
electrical measurements
TL175 TwistGuard
Te
s
t Lead
s
P
robes meet new IE
C
6
1
0
1
0
-
03
1
requireme
n
P
atented e
x
s
he
a
th me
e
C
AT III 1
00
C
AT IV
600
requir
e
-
m
ent
s
w
hile pro
-
v
iding the
f
lexibility
you need for CAT II measurements
Ne
w
Wear
G
uard
te
s
t le
a
d we
a
r
indicator that changes color when
leads are damaged and in need
o
f
replacemen
t
P
r
o
be
s
always
s
h
o
w
co
rre
c
t
category ratin
g
f
or tip being
u
s
ed
Adv
a
n
c
ed
s
tr
a
in relie
f
ex
c
eed
s
5,
000
bend lif
e
T
P175 probes
f
it standard test lead
s
T
L2
3
8 SureGrip
Te
s
t Lead Set f
o
r
hi
g
h ener
g
y environment
s
Insulated tip
probes help
l
e
ss
en ri
s
k
of
a
r
c
f
l
as
h
explosio
n
P
r
o
be extend
-
ers keep
hands away
f
r
o
m live
c
urren
t
Includes one pair each, insulated
t
est tip probes, probe extenders and
TL
22
4 Te
s
t Le
a
d
s
P
robes and leads
C
AT III 1
000
V,
C
AT IV
600
V, 1
0
A, extenders
C
AT
III 1
000
V 1
0
A
Simply twist
probe handle
Shroud
drops
TL71 Premium DMM Test Lead
S
e
t
Fl
ex
ibl
e s
ili
cone
i
nsu
l
ate
d
l
ea
d
s
are
h
eat an
d
co
ld
res
i
stan
t
Distinctive comfort
g
r
i
p pro
b
es
R
ecommended for
µV
measurement
s
CAT III 1000 V
,
10 A
,
CAT IV 600 V
,
10
A
TL75 Hard Point Test Lead
S
e
t
E
xtreme
ly
h
ar
d
a
ll
o
y
t
i
ps res
i
st
w
ear
Distinctive comfort
g
r
i
p pro
b
es
1
.
5
m PVC leads
CAT III 1000 V
,
1
0 A
,
CAT IV
6
00 V
,
10 A
AC220
SureGri
p
Alligator Clips
ator
Clips
Insulated, nickel plate
d
d
jaws grip
o
bjects up to 3/8 in.
B
lunt tip grabs round
sc
rew he
a
d
s
C
AT III 1
000
V,
C
AT IV
600
V, 1
0
A
AC
7
2
Alli
g
ator
C
lip
s
S
lide-on style for test pr
o
Jaws open to 8 mm
Fo
r u
s
e with TL71
a
nd
T
L75 test lead and probe
s
et
s
C
AT III 1
000
V, 1
0
A,
C
AT IV
600
V, 1
0
A
AC280
SureGrip
Hook
Profile narrows to .
22
i
Hook opening .
20
in.
a
.08 in. at bas
e
C
AT III 1
000
V,
C
AT IV
600
V,
3
A
59
A
cce
ss
or
i
e
s
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/accesso
ri
es
80
TK Thermocou
p
le Module
Converts K-T
y
pe thermocouple
s
i
g
nals into mV outpu
t
Co
nne
c
t
s
t
o
DMM vi
a
s
tandard banana plu
gs
S
wit
c
h
s
ele
c
t
a
ble
°C
o
r
°F
R
an
g
e: -50
°
C to 1000
°
C
(
-58
°
F to 1832
°
F
)
Includes 80PK-1
p
robe
80
T-15
0
UA Univer
s
al S
o
lid State
Tem
p
erature Prob
e
F
or measurement o
f
air,
s
ur
fac
e
a
nd n
o
n-
co
rr
os
ive
ma
teri
a
l
s
M
easurement ran
g
e:
-50
°
C to 150
°
C
(
-58
°
F to 302
°
F
)
Out
p
ut: 1 mV/°C or 1 mV/°F (switch
s
electable
)
Co
nne
c
t
s
t
o
DMM vi
a
s
t
a
nd
a
rd b
a
n
a
n
a
p
lu
gs
80
AK-A DMM Ada
p
te
r
A
dapts K-t
y
pe thermocouple
m
ini-
co
nne
c
t
o
r t
o
du
a
l
b
anana plu
g
inputs
Com
p
atible with all Fluke
DMMs with tem
p
erature
m
e
as
urement
f
un
c
ti
o
n
s
M
easurement ran
g
e and accurac
y
i
s not affected b
y
the 80AK-A adapter
80
BK-A Inte
g
rated DMM
Tem
p
erature Prob
e
Com
p
atible with all Flu
k
DMMs with tem
p
erature
m
e
as
urement
f
un
c
ti
o
n
s
K-T
y
pe thermocouple
w
ith
s
t
a
nd
a
rd b
a
n
a
n
a
j
ac
k
Convenient one-
p
iece construction
M
easurement ran
g
e: -40
°
C to 260
°
C
(
-40
°
F to 500
°
F
)
Fl
u
k
e Tem
p
erature accessor
i
e
s
Turn your digital multimeter into a thermometer
B
P721
7
N
i
C
d rechargeable ba
t
-
tery; nominal 7.
2
volt,
1
7
00
mA h
r
Use in
8
67B meters or
7
00
and 74
0
Series
Ca
libr
a
t
o
r
s
B
P72
35
N
iMH rechargeable
b
attery; nominal
7.
2
volt,
3
5
00
mA h
r
Use in 7
00
and 74
0
S
erie
s
Ca
libr
a
t
o
r
s
7
00LTP-1 Low Pressure Test Pump
H
and operated pressure
p
ump designed to generate
e
ither vacuum to -13 psi/
-.
90
bar or pressures to
1
00 psi/6.9 bar. Ideal for
l
ow pressure applications
requiring accurate low pres
-
s
ure testing
.
700
ILF In-lin
e
Filt
er
T
he Fluke 7
00
ILF can
b
e u
s
ed t
o
i
so
l
a
te the
ca
libr
a
t
o
r
f
r
o
m in
c
iden
-
t
a
l
co
nt
ac
t with
f
luid
s
.
Particularly use
f
ul with
the 71
8
calibrator to help keep moi
s
-
ture or oils
f
rom contaminating the
o
n-board pump
.
7
00PTP-1 Pne
u
matic Te
s
t
P
ump
T
he Fluke 7
00
PTP is a handhel
d
p
ressure pump designed
to generate either vacuum to
-11.6 psi/-0.8 bar or pressure
to 600 psi/40 bar
.
Th
ermocoup
l
e
Pl
ug
Ki
ts
700
T
C
1
A
kit of 10 mini-plu
g
c
onnectors.
O
ne each o
f
the followin
g
:
Ty
pe J (black
)
Ty
pe K (
y
ellow)
Ty
pe T (blue)
Ty
pe E (purple)
Ty
pe R/S (
g
reen
)
Ty
pe B or Cu (white)
Ty
pe L (J-DIN) (blue)
T
y
pe U (T-DIN) (brown
)
Ty
pe C (red
)
Ty
pe N (oran
g
e)
700
T
C2
A
kit of 7 mini-plu
g
c
onnectors.
Ty
pe J (black), two
Ty
pe K (
y
ellow), tw
o
Ty
pe E (purple), one
Ty
pe T (blue), on
e
Ty
pe R/S (
g
reen), one
O
ther tem
p
erature accessories
80PR-
6
0 RTD Tem
p
erature Prob
e
Re
s
i
s
t
a
n
c
e te
m
-
p
erature detector
probe desi
g
ned to
a
dd
co
nt
ac
t me
a
-
s
urements to
y
our
Fluke
66
and
68
N
o
n-
Co
nt
ac
t Infr
a
-
r
ed Therm
o
meter
s
Measurement ran
g
e: -40
°
C to 260
°
C
(
-40
°
F to 500
°
F
)
3
.5 mm phono t
y
pe
j
ack is onl
y
appr
o
-
p
riate for Fluke 66 and 68 Thermometer
s
80C
K-M and
80C
J-M
Ty
pe K and J Male
Mini-
Co
nnect
o
r
s
Iso
therm
a
l
sc
rew ter
-
m
in
a
l
fo
r K
o
r
J
wire
Suitable for u
p
to 20
g
au
g
e thermocouple
w
ire
C
olor coded to industr
y
s
tandards (K-
y
ellow,
J
-black
)
T
wo per packa
g
e
80
PJ-EXT,
80
PK
-
EXT,
80
PT-EXT
Thermocou
p
le
Wire Exten
s
i
o
n
Kit
s
F
or extendin
g
and
r
epairin
g
J, K or
T-t
y
pe
t
hermocou
p
le
wire
s
.
Kit includes
3
m (a
pp
rox. 9 ft.)
o
f
thermocou
p
le
wire and 1
p
air
of male
/
female
mini-
co
nne
c
t
o
r
s
Ma
ximum
con
-
t
inuous ex
p
osure
t
em
p
erature: 260
°
C
(
500
°
F
)
80PK-EXT is com
p
atible with
K-t
y
pe thermometers; 80PJ-EXT is
d
esi
g
ned
f
or J-T
y
pe thermometers,
a
nd 80PT-EXT is desi
g
ned for
T-t
y
pe thermometer
s
P
r
o
ce
ss
t
ools
acce
sso
r
i
e
s
7
00
HTP-1 H
y
draulic Test
Pum
p
The Fluke 7
00
HTP is
desi
g
ned to
g
enerate pre
s
-
sures u
p
to 10,000
p
si/700
bar. Use the Fluke-7
00
PRV
a
d
j
ustable relie
f
valves to
l
imit
p
ressures from 1360
p
s
i
t
o 5450
p
si.
7
00
HTH H
y
draulic
Te
s
t H
os
e
The 7
00
HTH is
a
10,000
p
si, 700 bar
t
e
s
t h
os
e th
a
t
co
nne
c
t
s
t
o
a
ca
libr
a
ti
o
n unit under te
s
t
f
rom a Fluke 700HTP h
y
draulic
t
est
p
um
p
.
7
00
PMP Pre
ssu
re
Pum
p
The 7
00
PMP is a hand-
o
p
erated
p
ressure
p
um
p
t
o
p
rovide
p
ressures u
p
t
o 150
p
si/1000 kPa.
Output fittin
g
is 1/8
F
NPT
.
Fl
u
ke 7
00
-IV
Cu
rrent Sh
u
nt
Co
nver
s
i
o
n f
ac
t
o
r:
1
0
mV = 1 mA
Accurac
y
(% of
i
nput, 1
y
ear): 0.025
%
In
p
ut current: 0 to 55 m
A
In
p
ut resistance: 250  nominal
Out
p
ut resistance: 10  nominal
Accurac
y
speci
f
ication applies
f
rom +1
8
°
C and 2
8
°
C to
50
°C
M
aximum input volta
g
e: 30 V d
c
F
or more in
f
ormation,
g
o to
w
ww.
f
luke.com/accessories
A
cce
ss
or
i
e
s
60
60
Fl
u
k
e current c
l
am
ps
For use with multimeters, ScopeMeters
and power quality analyzers
i200
s
i40
0
i800
i1000
s
i200 i200s i400 i400s i800 i1000s i3000s i2000 flex i3000s flex
A
C
current rang
e
1 A to
200
A
1 A to
200
A
1
A to 4
00
A
0
.5 A to 4
00
A
1
A to 800 A
0
.
2
A to
1000
A
1
A to
3000
A
2
A to
2000
A
3
A to
3000
A
A
ccurac
y
<
3
% +
0
.5
A
4
8 to 65 Hz
<
1 % +
0
.5 A
4
8 Hz to
65
H
z
2
% +
0
.
06
A
4
5 Hz to
400
Hz
.
5 A to 4
0
A,
2
%
+
.
015 A, 5 A to
400
A,
2
% +
.0
4 A
,
45 to
4
00
H
z
0
.1 A to
1
0
A ±
3
%
+
.01 A,
1
0
A to
200
A
±
2
%
,
200
A to
8
00 A ± 1 %
0
.
2
to 1
0
A:
3
% +
0
.1 A
10
A to
100
A
:
2
% +
0
.5 A
1
00
A t
o
1000
A
:
1
%
+ 1
A
48
to
65
Hz
1 to
30
A:
2
% +
0
.1 A 1
t
o 3
00
A:
2
% +
0
.5 A 1
t
o
3000
A:
2
%
+ 2
A
48 to 65 Hz
±
1 %
o
f
r
ange
45
to
65
H
z
Ranges:
20
A
,
200
A
,
2000
A
±
1 %
of
r
ange,
4
5 Hz
t
o
65
Hz
R
anges:
30
A
,
300
A
,
3000
A
B
andwidth
(
-3 dB
)
40
Hz to
4
0
kHz
40
Hz to
40
kH
z
5
kH
z to
20
kH
z
5
H
z to
10
kHz
30
Hz to
10 kHz (typical
)
5
H
z t
o
1
00
kH
z
10
Hz to
1
00
kH
z
10
Hz to
20
kH
z
1
0
Hz to
5
0
kHz
M
aximum conducto
r
dia
mete
r
20
mm
(
0.8 in
)
20
mm
(
0.8 in
)
3
2 mm
(
1.25 in
)
3
2 mm
(
1.25 in
)
54
mm
(
2.13 in
)
54
mm
(
2.13 in
)
6
4 x 1
00
mm
(
2.52 x 3.94 in
)
177 mm
(
7 in
)
1
77 mm
(
7
in
)
or
26
5 mm
(
10.4 in)
Maximum
co
n
d
u
c
t
o
r
si
z
e
300
MC
M
300
MCM 7
50
MCM
750
MC
M
2-
500
MCM or
1-1
000
M
CM
2-
500
MCM o
r
1-1
000
M
CM
6
4 mm
(
2.52 in
)
6
1
0
mm
(
24 in
)
c
ircum
f
erenc
e
6
1
0
mm or
9
15 mm
circum
f
erenc
e
O
utput levels 1 mA
/
A
1
0 mV
/
A
1
00 mV
/
A
1
mA
/
A 10 mV
/A
1 mV
/
A
1 mA
/A
1
mV
/A
1
0 mV
/
A
100 mV
/
A
1
0 mV
/
A
1 mV
/
A
0
.1 mV
/
A
1
00 mV
/A
10 mV
/A
1 mV
/
A
100 mV
/A
10 mV
/A
1
mV
/A
O
utput cabl
e
1
.
5
m
sh
r
o
u
d
e
d
b
anana p
l
ugs
2 m to BNC
t
erm
i
n
a
t
io
n
1.
5
m
sh
r
o
u
d
e
d
b
anana p
l
ug
s
2.
5
m to BNC
term
i
n
a
t
ion
1
.
6
m
sh
r
o
u
d
e
d
b
anana p
l
ugs
1
.
6
m to BN
C
t
erm
i
n
a
t
io
n
2
.1 m to BNC
term
i
n
a
t
io
n
2 m with
do
u
ble
s
h
rou
d
e
d
banana plu
g
s
2
.1 m to BNC
t
erm
i
n
a
t
io
n
W
arranty
O
ne-year
O
ne-year
O
ne-yea
r
O
ne-yea
r
O
ne-year
O
ne-year
O
ne-yea
r
O
ne-yea
r
O
ne-yea
r
Safety rating
C
AT III
600
V
C
AT III
600
V
C
AT III 1
000
V
CAT IV
600
V
C
AT III 1
000
V
C
AT IV
600
V
C
AT III
600
V
C
AT III
600
V
C
AT III
600
V
C
AT III
600
V
C
AT III
600
V
i3000s Flex
i2000 Flex
i6000s
6
A to
6000
A
Compatible with most
p
roducts except 434
/
435
Meter i200 i200s i400 i400s i800 i1000s i3000s i2000 Flex1i3000s Flex
10
/
11
/
12
/
12B
/
16
/
18
1
A to
2
00
A
1
A to
400
A
*
0
.1 A to
1
000
A*
1 A to
3
000
A
2
A to
2
000
A
3 A to
3000
A
1
10
/
111
/
112 3 A to
2
00
A
30
A to
4
00
A*
3 A to
1000
A
*
3
0
A to
3000
A
3 A to
2000
A
3
A to
3
000
A
1
14
/
116
1
A t
o
200
A
0
.
6
A to
400
A*
0
.
6
A to
1000
A*
1 A t
o
3000
A
2 A t
o
2000
A
3
A to
3000
A
115
/
117
60
A to
200
A
1
A
t
o
200
A
60
A to
4
00
A
0
.
6
A t
o
400
A
*
60
A to
800
A
0
.
6
A to
1
000
A*
1
A
t
o
3
000
A
2
A t
o
2
000
A
3
A to
3000
A
21
/
23
/
73
/
75
/
77
S
erie
s
II
I
1
A to
2
00
A
1
A to
200
A
1 A to
400
A
1 A to
4
00
A*
1
A to
800
A
0
.1 A to
1
000
A*
1
A to
3000
A
2
A to
2
000
A
3
A to
3
000
A
2
6
/
79 Series III 1 A t
o
40
A
1 A t
o
200
A
1
A to 4
0
A &
200
A to 4
00
A
2 A t
o
400
A*
1
A to 4
0
A &
2
00 A to 800
A
0
.2 A to
1000
A
*
2
A t
o
3000
A
2 A t
o
2000
A
3
A to
3000
A
27
1
A
t
o
200
A
1
A
t
o
2
00
A
1
A
t
o
400
A
1
A
t
o
400
A
*
1
A
t
o
800
A
0
.1 A to
1
000
A*
1
A
t
o
3
000
A
2
A t
o
2
000
A
3
A to
3000
A
233
60
A to
200
A
1 A to
200
A
60
A to
4
00
A
0
.
6
A to
4
00
A*
60
A to
800
A
0
.
6
A to
1
000
A*
1
A to
3
000
A
2
A to
2
000
A
3 A to
3
000
A
27II
2
A t
o
200
A
1
A t
o
200
A
2 A t
o
4
00
A
1 A t
o
4
00
A*
2 A t
o
800
A
0
.1 A to
1000
A
*
1
A t
o
3000
A
2
A t
o
2000
A
3
A to
3000
A
2
8II 1.8 A to
2
00
A
1
A
t
o
2
00
A
1.8 A to
400
A
1
.8 A to
4
00
A
1.8 A to
800
A
0
.
2
A to
1000
A*
2
A t
o
3
000
A
2
A t
o
2000
A
3
A to
3000
A
70
Series III
1
A to
2
00
A
1 A to
4
00
A
*
0
.1 A to
1
000
A*
1 A to
3
000
A
2
A to
2
000
A
3 A to
3
000
A
1
75
/
177
/
17
9
3 A to
200
A
1
A t
o
200
A
3
A to
4
00
A
1 A t
o
4
00
A*
3
A to
800 A
0
.3 A to
1
000
A
*
3
A to
3000
A
2
A t
o
2000
A
3
A to
3000
A
1
577
/
1587
Insulation Meter
3
A to
2
00
A
1
A
t
o
2
00
A
3
A to
4
00
A
3
A to
4
00
A*
3
A to
4
00
A
0
.
3
A to
1000
A
*
3
A to
3000
A
2
A t
o
2000
A
3
A to
3
000
A
83III
/
83V
/
88
V
2 A to
200
A
1 A to
2
00
A
2
A to
4
00
A
1
A to
400
A
*
2
A to
800
A
0
.1 A to
1000
A*
1 A to
3
000
A
2 A to
2000
A
3 A to
3000
A
85
/
87 Series III
87 Series V
2 A t
o
200
A
1 A t
o
200
A
2
A t
o
400
A
2
A t
o
400
A
*
2 A t
o
8
00 A
0
.2 A to
1
000
A*
2 A t
o
3000
A
2 A t
o
2000
A
3 A to
3000
A
8
7
/
89 Series I
V
1
87
/
189
2
.5 A to
2
00
A
1
A
t
o
200
A
2
.5 A to
400
A
1
A
t
o
400
A
*
2
.5 A to
800
A
0
.1 A to
1000
A*
1
A
t
o
3
000
A
2
A t
o
2
000
A
3
A to
3
000
A
287
/
28
9
1
A to
2
00
A
1
A to
200
A
1 A to
4
00
A
0
.
5
A to
4
00
A*
1
A to
800
A
0
.2 A to
1
000
A
*
1
A to
3000
A
2
A to
2
000
A
3
A to
3
000
A
8
060A
/
8062A
DMMs
2
A t
o
200
A
1
A t
o
200
A
2 A t
o
4
00
A
2
A t
o
4
00
A
*
2 A t
o
8
00 A
0
.2 A to
1
000
A*
2 A t
o
3000
A
2
A t
o
2000
A
3 A to
3000
A
8
60 Series Gra
p
hical
M
ultimeter
s
1
A
t
o
2
00
A
1
A
t
o
200
A
1
A
t
o
4
00
A
3
A to
4
00
A*
1
A
t
o
800
A
0
.
3
A to
1
000
A
*
3
A to
3000
A
2
A t
o
2
000
A
3
A to
3
000
A
39
/
41B Powe
r
M
ete
r
1 A to
200
A
2
1 A to
400
A
2
0
.1 A to
1
000
A
2
1 A to
3
000
A
2
2
A to
2
000
A
2
3 A to
3
000
A
2
43B Power
Q
uality Analyzer
1
A t
o
200
A
0
.3
5
A to
4
00
A
0
.1 A to
1000
A
1 A t
o
3000
A
2 A t
o
2000
A
3 A to
3000
A
4
34
/
435 Power
Qualit
y
Anal
y
zer
1
A
t
o
2
00
A
1
.
2
A t
o
4
00
A
0
.
3
A to
1000
A
1.
2
A t
o
3
000
A
B
e
s
t t
o
u
s
e
i43
0
Flex
B
e
s
t t
o
u
s
e
i
43
0
Fle
x
9
X ScopeMeter
S
erie
s
1
A to
2
00
A
1 A to
400
A
0
.1 A to
1000
A
1
A to
3
000
A
2
A to
2
000
A
3 A to
3
000
A
1
2
0
Series
Sco
p
eMeters
1 A t
o
200
A
2
.
5
A to
400
A
0
.2
5
A to
1000
A
2.
5
A to
3000
A
2
A t
o
2000
A
3 A to
3000
A
190
Series
Scopemeters
1
A
t
o
2
00
A
1
A
t
o
400
A
0
.1 A to
1
000
A
1
A
t
o
3000
A
2
A t
o
2000
A
3
A to
3
000
A
45
DMM 1.
5
A to
100
A
1
A to
2
00
A
1.
5
A to
100
A
1
.
5
A to
4
00
A
*
1.
5
A to 1
00
A
&
5
00 A to 800 A
0
.1
5
A to
1
000
A*
1.
5
A to
3000
A
2 A to
2000
A
3
A to
3000
A
8808
A
1
A to
200
A
1 A to
200
A
1 A to
400
A
0
.
5
A to
400
A
*
1 A to
800
A
0
.1 A to
1
000
A*
1 A to
3
000
A
2 A to
2
000
A
3 A to
3000
A
8
845A
/
8846A
1
A t
o
200
A
1
A t
o
200
A
1 A t
o
400
A
1 A t
o
4
00
A*
1 A t
o
8
00 A
0
.2 A to
1
000
A*
1
A t
o
3000
A
2
A t
o
2000
A
3 A to
3000
A
74X
S
erie
s
Pr
oc
e
ss
Calibrators
1
.
1
A
t
o
200
A
11
A
t
o
4
00
A*
1
.
1
A
t
o
1000
A
*
11
A
t
o
3
000
A
2
A t
o
2
000
A
3
A to
3
000
A
787
/
789 Process
M
eter
s
50
A to
2
00
A
1
A to
200
A
50
A to
400
A
2
A to
400
A
*
50
A to
4
4
0
A
0
.2 A to
1
000
A*
2 A to
3
000
A
2 A to
2
000
A
3 A to
3000
A
*
Requires PM9081
/
001 Adapters.
1
Three ran
g
e version.
2
Current and watt readings will be multiples of 10 higher or lower than actual on some ranges
.
AC current clam
p
s
p
ecification
s
A
C
current clamp selection
g
uide
AC only models
61
A
cce
ss
or
i
e
s
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/accesso
ri
es
AC/DC models
Fl
u
k
e current c
l
am
ps
For use with multimeters, ScopeMeters
and power quality analyzers
80i-110s i410 i1010 i30 i30s i310s
DC
range
0
.1 A to 1
00
A
1 to 4
00
A
1
to 1
000
A
30
mA to
30
A
30
mA to
30
A
0
.1A to 45
0
A
A
C
range
0
.1 A to 7
0
A
1 A to 4
00
A
1
A to
600
A
30
mA to
20
A rm
s
30
mA to
20
A rm
s
0
.1A to
300
A
Accurac
y
0
.1 A to 10 A; dc to
1
kHz: ±
3
% + 5
0
mA;
u
p
to 1
00
A add 15 %;
u
p to 20 kHz add 12 %
3
.
5
% +
0
.
5
A for dc or
a
c
(
45 to 400 Hz
)
2
% +
0
.
5
A for dc or ac
(
45 to 400 Hz
)
±
1 % of readin
g
,
±2mA
± 1 % of readin
g
,
±2mA
30 A ran
g
e: 1 % +
50
mA
300
A range: 1 % +
3
00
mA
B
andwidth
(
-3 dB
)
100
kH
Z
3
kHz
10
kH
z
d
c to 20 kHz
(
-0.5 dB
)
d
c to 100 kHz
(
-0.5 dB
)
DC
to
20
kHz
Z
ero error a
dj
ustment
Y
e
s
Y
e
s
Y
es
Y
es
Y
e
s
Y
e
s
M
aximum conductor
dia
meter
1
1.
8
mm
(
0.46 in) 30 mm
(
1.1
8
in
)
3
0 mm
(
1.1
8
in
)
1
9 mm
(
0.75 in)
1
9 mm
(
0.75 in)
1
9 mm
(
0.75 in
)
M
ax
i
mum con
d
uctor
s
ize
1
AW
G
7
5
0
M
C
M or
2
-5
00
MCM
7
5
0
M
C
M or
2
-5
00
M
CM
2
5
0
M
CM
2
5
0
M
C
M
2
5
0
M
C
M
O
ut
p
ut level
s
10 mV
/
A, 100 mV
/
A1 mV
/A
1
mV
/A
1
00 mV
/A
100 mV
/
A
1
mV
/
A, 10 mV
/
A
O
ut
p
ut cabl
e
1
.
6
meter with BN
C
t
ermination
1.
2
m
e
t
e
r with
s
hrouded banana
pl
ug
s
1.
2
m
e
t
e
r with
shrouded banana
p
l
ugs
1
.
5
meter w
i
t
h
s
hrouded dual
b
anana
pl
ue
2
meter with BN
C
termination
2 meters with BNC ter
-
r
r
mination and a BNC to
safety shrouded banana
a
d
a
p
ter
Batter
y
lif
e
4
0
hour
s
60
hour
s
60
hours 3
0
hours 3
0
hour
s
30
hour
s
W
arrant
y
O
ne-
y
ear
O
ne-
y
ear
O
ne-
y
ea
r
O
ne-
y
ea
r
O
ne-
y
ear
O
ne-
y
ear
S
afety
C
AT II
600
V
;
C
AT III 3
00
V
C
AT III
600
V
C
AT III
600
V
C
AT III
300
V
C
AT III
300
V
C
AT III
300
V
i
41
0
i1010
80i-110s
i
3
10s, i
3
0s and i
3
0
H
all Effect AC
/
DC
C
urrent
C
lamps
E
speciall
y
useful for
l
ow current measur
e
-
m
ents down to 3
0
milli
amp
s
Meter 80i-110s i410 i1010 i30 i30s i310s
10
/
11
/
12
/
12B
/
16
/
1
8
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
5
A to 400 A dc
/
7 A to 4
00
A a
c
5 A to 1000 A dc
/
7 A to
600
A ac
4
0 mA to 30 A dc
/
60
mA to
20
A ac
40 mA to 30 A dc
/
60
mA to
20
A ac
0.4 A to 450 A dc
/
0
.
6
A to
300
A a
c
1
10
/
111
/
112
0
.14 A to 100 A dc
/
3 A to 7
0
A ac*
5
A to 400 A dc
/
3
00
A to 4
00
A a
c
5 A to 1000 A dc
/
300
A to
600
A a
c
40 mA to 30 A dc
/
3 A to 2
0
A ac
4
0 mA to 30 A dc
/
3 A to 2
0
A a
c
0
.4 A to 450 A dc
/
3
0
A to 3
00
A ac
114
/
115
/
116
/
11
7
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1.4 A to 400 A dc
/
6
A to 4
00
A a
c
1.4 A to 1000 A dc
/
6
A to
600
A a
c
30 mA to 30 A dc
/
60
mA to 2
0
A a
c
3
0 mA to 30 A dc
/
60
mA to 2
0
A a
c
0
.1 A to 450 A dc
/
0
.
6
A to 3
00
A ac
2
1
/
23
/
70
/
73
/
75
/
77
S
erie
s
III
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1 A to 400 A dc
/
5
A to 4
00
A ac
1
A to 1000 A dc
/
5
A to
600
A ac
3
0 mA to 30 A dc
/
40
mA to
20
A ac
30 mA to 30 A dc
/
4
0
mA to
20
A ac
0.1 A to 450 A dc
/
0
.4 A to
300
A a
c
26
/
79 Series II
I
0.1 A to 100 A dc
/
0
.2 A to 7
0
A ac*
1
A to 400 A dc
/
2
0
A to 4
00
A a
c
1 A to 1000 A dc
/
2
0
A to
600
A a
c
3
0 mA to 30 A dc
/
2
00
mA to 2
0
A a
c
30 mA to 30 A dc
/
2
00
mA to 2
0
A ac
0.1 A to 450 A dc
/
2 A to 3
00
A a
c
233
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1.4 A to 400 A dc
/
6
A to 4
00
A a
c
1.4 A to 1000 A dc
/
6
A to
600
A a
c
30 mA to 30 A dc
/
60
mA to 2
0
A a
c
3
0 mA to 30 A dc
/
60
mA to 2
0
A a
c
0
.1 A to 450 A dc
/
0
.
6
A to 3
00
A ac
27
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1 A to 400 A dc
/
1 A to 4
00
A a
c
1
A to 1000 A dc
/
1
A to
600
A ac
3
0 mA to 30 A dc
/
30
mA to
20
A a
c
30 mA to 30 A dc
/
30
mA to
20
A ac
0.1 A to 450 A dc
/
0
.1 A to
300
A a
c
27II
0.1 A to 100 A dc
/
0
.1 A to 7
0
A ac*
1
A to 400 A dc
/
1
A to 4
00
A ac
1 A to 1000 A dc
/
1 A to
600
A a
c
30 mA to 30 A dc
/
3
0
mA to 2
0
A ac
3
0 mA to 30 A dc
/
30
mA to 2
0
A a
c
0
.1 A to 450 A dc
/
0
.1 A to 3
00
A ac
2
8II
0
.1 A to 100 A dc
/
0
.2 A to 7
0
A ac
*
1 A to 400 A dc
/
6
A to 4
00
A a
c
1
A to 1000 A dc
/
6
A to
600
A a
c
3
0 mA to 30 A dc
/
60
mA to 2
0
A a
c
30 mA to 30 A dc
/
60
mA to 2
0
A ac
0.1 A to 450 A dc
/
2 A to 3
00
A a
c
77
-
IV
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1 A to 400 A dc
/
5
A to 4
00
A a
c
1
A to 1000 A dc
/
5
A to
600
A a
c
3
0 mA to 30 A dc
/
40
mA to
20
A a
c
30 mA to 30 A dc
/
4
0
mA to
20
A ac
0.1 A to 450 A dc
/
0
.4 A to
300
A a
c
175
/
177
/
17
9
0
.11 A to 100 A dc
/
0
.3 A to 7
0
A ac
*
1
.6 A to 400 A dc
/
3
0
A to 4
00
A ac
1.6 A to 1000 A dc
/
3
0
A to
600
A ac
30 mA to 30 A dc
/
3
00
mA to 2
0
A a
c
3
0 mA to 30 A dc
/
3
00
mA to 2
0
A a
c
0
.1 A to 450 A dc
/
3 A to 3
00
A ac
1
577
/
1587
Insulation Meter
0.1 A to 100 A dc
/
0
.3 A to 7
0
A ac*
1
.2 A to 400 A dc
/
30
A to 4
00
A a
c
1
.2 A to 1000 A dc
/
3
0
A to
600
A ac
30 mA to 30 A dc
/
3
00
mA to 2
0
A ac
3
0 mA to 30 A dc
/
3
00
mA to 2
0
A a
c
0
.1 A to 450 A dc
/
3 A to 3
00
A ac
8
3-III
/
83-V
/
88-
V
0.1 A to 100 A dc
/
0
.1 A to 7
0
A ac*
1
A to 400 A dc
/
1 A to 4
00
A a
c
1 A to 1000 A dc
/
1 A to
600
A a
c
30 mA to 30 A dc
/
30
mA to
20
A a
c
3
0 mA to 30 A dc
/
30
mA to
20
A a
c
0
.1 A to 450 A dc
/
0
.1 A to
300
A ac
85-III
/
87-III
/
87-V
0
.1 A to 100 A dc
/
0
.2 A to 7
0
A ac
*
1 A to 400 A dc
/
20
A to 4
00
A ac
1
A to 1000 A dc
/
20
A to
600
A ac
30 mA to 30 A dc
/
2
00
mA to 2
0
A ac
3
0 mA to 30 A dc
/
200
mA to 2
0
A a
c
0
.1 A to 450 A dc
/
2
A to 3
00
A ac
8
7-IV
/
89-IV
/
1
87
/
18
9
0.1 A to 100 A dc
/
0
.1 A to 7
0
A ac*
1
A to 400 A dc
/
2
.
5
A to 4
00
A a
c
1
A to 1000 A dc
/
2.
5
A to
600
A ac
3
0 mA to 30 A dc
/
3
0
mA to 2
0
A ac
30 mA to 30 A dc
/
3
0
mA to 2
0
A ac
0.1 A to 450 A dc
/
0
.2
5
A to 3
00
A a
c
287
/
289 0.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1 A to 400 A dc
/
1
A to 4
00
A ac
1 A to 1000 A dc
/
1
A to
600
A ac
3
0 mA to 30 A dc
/
30
mA to
20
A ac
30 mA to 30 A dc
/
30
mA to
20
A ac
0.1 A to 450 A dc
/
0
.1 A to
300
A a
c
8
060A
/
8062A
DMMs
0.1 A to 100 A dc
/
0
.2 A to 7
0
A ac*
1
A to 400 A dc
/
2
0
A to 4
00
A a
c
1
A to 1000 A dc
/
20
A to
600
A a
c
3
0 mA to 30 A dc
/
200
mA to 2
0
A a
c
30 mA to 30 A dc
/
2
00
mA to 2
0
A a
c
0.1 A to 450 A dc
/
2 A to 3
00
A a
c
860 Series Gra
p
hical
Multimeters
0.1 A to 100 A dc
/
0
.3 A to 7
0
A ac
*
1 A to 400 A dc
/
3
0
A to 4
00
A ac
1 A to 1000 A dc
/
30
A to
600
A a
c
30 mA to 30 A dc
/
300
mA to 2
0
A ac
3
0 mA to 30 A dc
/
3
00
mA to 2
0
A ac
0
.1 A to 450 A dc
/
3 A to 3
00
A a
c
39
/
41B Powe
r
Me
t
er
Usabl
e
b
ut w
ill
re
ad
1
0
or 1
00
times
hi
g
he
r
1 A to 4
00
A ac**
Not s
p
ec’d
f
or dc
1 A to
600
A ac**
N
ot s
p
ec’d
f
or d
c
Usabl
e
b
ut w
ill
re
ad
1
00
times higher*
*
Usabl
e
b
ut w
ill
re
ad
1
00
times higher
Not s
p
ec’d for dc
0
.
6
A to
300
A a
c
9X Sco
p
eMete
r
S
erie
s
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A a
c
1
A to 400 A dc
/
5
A to 4
00
A ac**
1
A to 1000 A dc
/
5 A to
600
A ac**
30 mA to 30 A dc
/
5
0
mA to
20
A ac**
3
0 mA to 30 A dc
/
5
0
mA to
20
A a
c
0
.1 A to 450 A dc
/
0
.5 A to
300
A ac
123
/
124
S
co
p
eMeters
0.1 A to 100 A dc
/
0
.2
5
A to 7
0
A a
c
1 A to 400 A dc
/
25
A to 4
00
A ac**
1
A to 1000 A dc
/
2
5
A to
600
A ac**
3
0 mA to 30 A dc
/
2
50
mA to 2
0
A ac**
30 mA to 30 A dc
/
2
50
mA to 2
0
A a
c
0.1 A to 450 A dc
/
2
.
5
A to 3
00
A a
c
190
Series
S
copemeter
s
0.1 A to 100 A dc
/
0
.1 A to 7
0
A a
c
1
A to 400 A dc
/
5
A to 4
00
A ac*
*
1
A to 1000 A dc
/
5
A to
600
A ac**
30 mA to 30 A dc
/
50
mA to 2
0
A ac*
*
3
0 mA to 30 A dc
/
50
mA to 2
0
A a
c
0
.1 A to 450 A dc
/
0
.
5
A to 3
00
A ac
45 DM
M
0
.1 A to 100 A dc
/
0
.15 A to 7
0
A ac*
1 A to 400 A dc
/
15 A to 4
00
A a
c
1 A to 1000 A dc
/
1
5 A to
600
A a
c
30 mA to 30 A dc
1
5
0
mA to
20
A a
c
30 mA to 30 A dc
15
0
mA to
20
A a
c
0
.1 A to 450 A dc
/
1.5 A to
300
A ac
8808
A
0
.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1 A to 400 A dc
/
2 A to 4
00
A a
c
1
A to 1000 A dc
/
2 A to
600
A ac
3
0 mA to 30 A dc
/
30
mA to 2
0
A a
c
30 mA to 30 A dc
/
3
0
mA to 2
0
A ac
0.1 A to 450 A dc
/
0
.2 A to 3
00
A a
c
8845A
/
8846A 0.1 A to 100 A dc
/
0
.1 A to 7
0
A ac
*
1
A to 400 A dc
/
1
A to 4
00
A ac
1 A to 1000 A dc
/
1 A to
600
A a
c
30 mA to 30 A dc
/
3
0
mA to 2
0
A ac
30 mA to 30 A dc
/
30
mA to 2
0
A a
c
0.1 A to 450 A dc
/
0
.1 A to 3
00
A ac
705
/
70
7
0.1 A to 100 A dc,
No
ac*
4
A to 400 A dc,
No
ac
4 A to 1000 A dc,
No
ac
4
0 mA to 30 A dc,
No
ac
40 mA to 30 A dc,
No
ac
0
.4 A to 450 A dc,
No
ac
7
1
5
0.1 A to 100 A dc,
No
ac*
4
A to 400 A dc,
No
ac
4
A to 1000 A dc,
No
ac
4
0 mA to 30 A dc,
No
ac
4
0 mA to 30 A dc,
No
ac
0
.1 A to 450 A dc,
No
ac
7
4X
S
erie
s
Pr
oc
e
ss
C
alibrators
0
.1 A to 100 A dc
/
1.1 A to 7
0
A ac
*
1 A to 400 A dc
/
1
1
0
A to 4
00
A a
c
1 A to 1000 A dc
/
1
1
0
A to
600
A a
c
30 mA to 30 A dc
/
1.1 A to 2
0
A a
c
3
0 mA to 30 A dc
/
1
.1 A to 2
0
A a
c
0
.1 A to 450 A dc
/
1
1 A to 3
00
A a
c
7
87
/
789 Process
M
eter
s
0
.1 A to 100 A dc
/
0
.
2
A to 7
0
A ac
*
1 A to 400 A dc
/
20
A to 4
00
A a
c
1 A to 1000 A dc
/
20
A to
600
A a
c
3
0 mA to 30 A dc
/
200
mA to
20
A ac
3 mA to 30 A dc
/
200
mA to
20
A ac
0.1 A to 450 A dc
/
2
A to
300
A a
c
* Requires PM90
8
1 Adapte
r
** Re
q
uires PM9082
/
001 Ada
p
te
r
***Only for use with the 4
30
Series Power
Q
uality Analyzers
AC
/
DC current clam
p
s
p
ecifications
AC/DC current clamp selection
g
uid
e
i30
i
30
s
i
31
0
F
or more in
f
ormation,
g
o to
w
ww.
f
luke.com/accessories
A
cce
ss
or
i
e
s
62
62
LVD1 Volt Li
g
h
t
E
xclusive dual-sensitivit
y
Detects voltages from 4
0
V ac to
300
V ac
Voltage detector glows blue at 5
0
Hz to
6
0 Hz or 2.5 cm to 3
8
cm
(
1 in to 5 in
)
away
f
rom sourc
e
Ultra-bright white LED with 1
00
,
000
ho
ur bulb li
f
e
A
AA battery include
d
LVD
2
Volt Li
g
h
t
N
on-contact ac voltage detector and
b
right white LED
f
lashlight
Detects voltage from
90
V to
600
V ac
f
rom 1 to 5 inches awa
y
C
AT IV rated, one-year warranty
L
20
5 Mini Hat Li
g
ht
R
ugged, high-intensity Xenon worklight.
A
ttaches to a baseball cap
Includes a hat cli
p
In
c
lude
s
tw
o
AAA b
a
tterie
s
Waterproo
f
Fl
u
k
e
li
g
h
ts an
d
h
anger
s
Free your hands and shed light on the contact point
L
215 SureGri
p
Ki
t w
i
t
h
P
ro
b
e
Li
g
h
t an
d
P
ro
b
e
E
xten
d
ers
L
200 probe li
g
ht
T
P220 SureGri
p
test
p
robes
T
L224 SureGri
p
test lead
s
T
P280 test
p
robe extender
s
S
oft foldable
p
ouch, kee
p
s the entire
s
et to
g
et
h
e
r
L2
1
0
Probe Li
g
ht and Probe Extenders
8
inch
p
robe extenders fit modular test
p
robes
P
robe and extender len
g
th complies with
N
FPA re
co
mmend
a
ti
o
n
s
B
ri
g
ht white LED illuminates contact
a
re
a
P
robe li
g
ht
f
its on extender or test probe
TPAK
T
oo
lP
a
k
M
agnet
i
c
M
eter Han
g
er
F
ree
bo
t
h
ha
n
ds
t
o
m
ak
e
m
e
as
uremen
ts
Hang your meter
f
rom metallic
s
ur
f
aces like panels and pipes
Ki
t
i
nc
l
u
d
es un
i
versa
l
h
anger c
li
ps
(
two), hook and loop straps
(
two
l
engths
)
, adapter and strong magnet
A
ttaches to back o
f
many Fluke
m
eters, including 110, 170, 1
8
0,
2
8
0 Series,
8
7V and
8
3V DMMs,
7
24, 725 and 7
8
9 Process Calibr
a
-
tors, 7
0
Series III DMMs, 15
03
,
1
507, 1577 and 15
8
7 Insulation
M
ultimeters and 5
0
Series II Digital
T
herm
o
meter
s
L
20
6
Deluxe LED Hat Li
g
ht
(hard hat not included
)
Attach it to a hard hat, a baseball cap
,
or even a panel door
f
or all the light
you need.
T
hree super bright white LEDs—never
burn
o
u
t
S
pecial hard-hat attachment included
40
-hour battery life
I
n
c
lude
s
three AAA b
a
tterie
s
63
A
cce
ss
or
i
e
s
F
or more in
f
ormation,
g
o to www.fl
u
k
e
.
co
m
/accesso
ri
es
Stray voltage
SV
22
5
E
liminates stra
y
volta
ge
d
ue to ca
p
acitance
b
etween wires in
e
lectrical installation
s
Com
p
atible with all
i
nstruments and test le
a
that accept standard 4 mm shrouded
b
anana connector
s
P
ressure an
d
vacuu
m
PV350 Pressure Vacuum Module
Digi
ta
l
pressure
an
d
vacuum
m
easurements
in
a s
i
n
gl
e mo
d
u
le
M
easures
HVAC
/
R
,
hyd
rau
li
c an
d
p
neumat
i
c press
u
to 350 psi
g/
2413
to 500 psi
g)
M
easures to 76 cm H
g
(
29.9 in H
g
)
vacuum
(
not intended for measurin
g
m
icrons of vacuum)
Compatible with most di
g
ital multimeters
S
p
ecialt
y
accessories and softwar
e
Get more out of your multimeter
Fuse selection
g
uide
R
eplacement
f
uses
f
or Fluke DMMs are available
f
rom
y
our distributor. To order
direct from Fluke call 1-
8
00-44-FLUKE
(
U.S.) or email fluke-info@fluke.com.
Model Fuse Requirements
21-III
/
75-III
/
73-III P
/
N 871173 630mA 250V fuse
P
/
N 803293 11A 1000V fus
e
27 (S/N<7247001) P
/
N 871173 630mA 250V fuse
P
/
N 871202 3A 600V fuse
P
/
N 892583 15A 600V fus
e
27 (S
/
N>724700
1
P
/
N 943121 440mA 1000V fuse
P
/
N 803293 11A 1000V fus
e
83
/
85
/
87
(
S
/
N>6565000
)
P
/
N 943121 440mA 1000V fuse
P
/
N 803293 11A 1000V fus
e
83-III
/
85-III
/
87-III 87-IV
/
89-IV
/
187
/
189
/
287
/
289
/
77
-
III
/
79-III
/
23-III
/
26-III
/
175
/
177
/
179
/
77-IV
/
27-II
/
28-I
I
P
/
N 943121 440mA 1000V fuse
P
/
N 803293 11A 1000V fus
e
111
/
112
/
115
/
117
/
233 P
/
N 803293 11A 1000V fus
e
1577
/
158
7
P
/
N 943121 440mA 1000V fus
e
1503
/
150
7
P
/
N 2279339 315mA 1000V fus
e
787
/
78
9
P/N 943121 440mA 1000V fuse (Qty 2
)
Logging software
FlukeView
®
F
o
rm
s
Harness the power o
f
the data lo
gg
in
g
f
unction on
y
our Fluke Di
g
ital Multimeter,
Thermometer or ProcessMeter. Lo
g
live
r
eadin
g
s while connected to a PC, or
l
eave
y
our Fluke 289, 789 or 54-II in
place to capture up to 1,000 readin
g
s for
d
o
wnl
oa
d t
o
a
P
C
.
C
hoose the model thats ri
g
ht for you:
F
VF-S
C
2: In
c
lude
s
sof
tw
a
re
a
nd
ca
ble
u
sed with 2
80
Series DMMs and 7
8
9
ProcessMeters, and the 1550B Insul
a
-
t
i
o
n Te
s
ter
F
VF-S
C
3: In
c
lude
s
sof
tw
a
re
a
nd
ca
ble
u
sed with
45
Bench Meters
F
VF-S
C
4
:
In
c
lude
s
sof
tw
a
re
a
nd
cable used with
88
4
5
A and
88
4
6
A
Multimeter
s
G
o to
w
ww.fluke.com/flukeviewforms
t
o
d
own
l
oa
d
t
h
e
d
emo.
Fl
u
k
e
Vi
ew
®
F
orms
B
as
i
c
An abrid
g
ed version of FlukeView Forms
.
Available for use with 2
80
Series
DMMs and 789 ProcessMeters, onl
y
Up
g
rade to the full FlukeView Forms
with FVF-U
G
Com
p
atible with the 280 and 789
ser
i
es on
ly
Selection
Guide
1
0
/
11
/
12
/
12B
1
10/111/112
1
14
/
115
/
116
/
11
7
2
0/70 Series
2
7 II
/
28 II
/
27
7
0/73 III
1
75
/
177
1
7
9
8
0 Series III
/
83V
8
7
/
89 IV
8
7
V
233
2
87/289/187/189
43B
9
0 Series
120
Serie
s
1
90 Serie
s
5
1
/
52
/
53
/
54 I
I
7
05
/
707
7
1
5
7
25
/
72
6
7
41/743
744
7
87/78
9
1
5
87
1577
FlukeView Forms
Software
•*
789
TPak
8
3
V
789
PV350 (pressure)
FOM (fiber optic)
CO-210
*53 B II, 54 B II onl
y
.
Fib
er o
p
t
i
c
s
FO
M Fiber
Op
tic
Meter
T
he Fluke Fiber O
p
tic
Meter (FOM) hel
p
s
y
ou test and mai
n
-
tain fiber o
p
tic cable
w
ithout havin
g
to bu
y
a whole new meter. Plu
g
the FOM directl
y
into an
y
DMM with a mV dc funtion and a
1
0 mW input impedance, and quickl
y
and
accuratel
y
verif
y
fiber optic cable s
y
stem
loss. Li
g
ht sources and patch cords sold
s
eparatel
y
.
F
OS
8
5
0
a
nd F
O
S
850
/
1300
F
iber
Op
tic
L
i
g
ht
S
ources
A variet
y
of LED li
g
ht
s
ources allow
y
ou to test di
f
-
f
erent cables.
www.
uke.com
/
catalogwww.
uke.com
/
catalog
C
omplete digital
C
omplete digital
cata
l
o
g
cata
l
o
g
Measurement sa
f
et
y
Measurement sa
f
et
y
N
ewest pro
d
uct
sN
ewest pro
d
uct
s
Wh
ere to
b
u
yWh
ere to
b
u
y
E
xten
d
e
d
spec
sE
xten
d
e
d
spec
s
O
nline Stor
eO
nline Stor
e
How-to in
f
ormatio
n
How-to in
f
ormatio
n
M
o
r
e
Fl
u
k
e
in
fo
o
nlin
e
M
o
r
e
Fl
u
k
e
in
fo
o
nlin
e
Yo
ur
a
ut
ho
r
i
ze
d
Fl
u
k
e
dis
tr
ib
ut
o
r
Fluke Corporation
PO Box 9090,
Everett, WA 98206 U.S.A.
Fluke. Keeping your world up and running.®
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2003-2011 Fluke Corporation. Specifications subject to change without notice. Microsoft is a reg-
istered trademark of Microsoft Corporation. Printed in U.S.A. 12/2010 1274458S C-US-N Volume 41
Modification of this document is not permitted without written permission
from Fluke Corporation.
C
ontact us
:C
ontact us
:
Unite
d
State
s
Unite
d
State
s
G
eneral
p
roduct and sales
G
eneral
p
roduct and sales
information: 1-
800
-44-FLUKEinformation: 1-
800
-44-FLUKE
uke-info
@
fluke.com
uke-info
@
fluke.com
Fl
u
k
e
Th
erma
l
I
ma
g
ers:
Fl
u
k
e
Th
erma
l
I
ma
g
ers:
1-800-760-4523 (U.S. onl
y
) all 1-800-760-4523 (U.S. onl
y
) all
other re
g
ions 1-425-446-4620other re
g
ions 1-425-446-4620
S
ervi
c
e
a
nd
ca
libr
a
ti
o
n:
S
ervi
c
e
a
nd
ca
libr
a
ti
o
n:
1-
888
-99-FLUK
E
1-
888
-99-FLUK
E
P
arts: 1-
8
00-526-4731
P
arts: 1-
8
00-526-4731
C
anada
C
anada
G
eneral product, sales, service,
G
eneral product, sales, service,
parts and calibration information: parts and calibration information:
1-
8
00-36-FLUK
E
1-
8
00-36-FLUK
E
canada
@
fluke.comcanada
@
fluke.com
A
ustra
liaA
ustra
lia
G
eneral product and sales
G
eneral product and sales
information:
(
02
)
88
50-3333information:
(
02
)
88
50-3333
P
arts:
(
02
)
88
50-3333
P
arts:
(
02
)
88
50-3333
S
ervi
c
e
a
nd
ca
libr
a
ti
o
n:
S
ervi
c
e
a
nd
ca
libr
a
ti
o
n:
(
02
)
9771-9300
(
02
)
9771-9300
S
in
g
apore
S
in
g
apore
G
eneral product and sales
G
eneral product and sales
information:
(
65
)
6799-556
6
information:
(
65
)
6799-556
6
info.asean
@
fluke.co
m
info.asean
@
fluke.co
m
S
ervice, parts and calibration:
S
ervice, parts and calibration:
(
65
)
6799-55
88(
65
)
6799-55
88
s
ervice.asean
@
fluke.co
ms
ervice.asean
@
fluke.co
m
J
a
p
an
J
a
p
an
G
eneral product and sales
G
eneral product and sales
information: +
8
1-3-3434-01
81
information: +
8
1-3-3434-01
81
S
ervice, parts and calibration:
S
ervice, parts and calibration:
+
8
1-3-3434-01
88
+
8
1-3-3434-01
88
O
ther countries:
O
ther countries: 1+
(
425
)
446-550
0
1+
(
425
)
446-550
0
Join the conversation
We design our products with you in mind. Yeah, we have
guys in lab coats, developing and testing our tools in
rooms we dare not enter. But our ideas, the things that
drive our intense development process, come straight from
the job site—from pros like you. You are the voice of Fluke’s
innovation. Tell us what you think. Visit our social media
sites, and get the conversation started. We’re listening.
www.facebook.com/fluke.corporation
www.twitter.com/flukecorp
www.youtube.com/flukecorporation

Navigation menu