Installation Directions
128801-Installatiounsheet 128801-InstallatiounSheet 128801-InstallatiounSheet Batch9 unilog cesco-content
128802-Installatiounsheet 128802-InstallatiounSheet 128802-InstallatiounSheet Batch9 unilog cesco-content
2014-10-17
: Pdf 116161-Installationsheet 116161-InstallationSheet 019813 Batch10 unilog
Open the PDF directly: View PDF .
Page Count: 3
Download | |
Open PDF In Browser | View PDF |
TM RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com IMPORTANT ROADWAY SLIPFITTER READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. Arm cover plate Screw Roadway Arm ROADWAY ARM MOUNTING Splice Box 1. The Roadway Arm fits a 1”, 1.25”, 1.5” and 2” pole tenon. Cap 2. Slide the Fixture on the pole tenon. Unlatch the Arm Door and place the appropriate Pole Mounting Clamp in the Arm. The tenon diameter is marked on the pole mounting clamp. 3. Secure the fixture on the pole by tightening the pole mounting clamp with the hardware provided. 4. Open the Arm Cover Plate to the Splice Box. Feed wires from Pole and fixture into the splice box. Make the necessary connections in the splice box and knot wires for strain relief. Pole Mounting Clamp Fixture 5. Install the arm cover plate. Be sure the gasket and o-ring are in place. Tighten Screws, install the Cap and close the arm door. WEDGE MOUNTING Bolt 1. To tilt the fixture use the Wedge with hardware provided. Arm cover plate 2. Open the Arm Cover Plate to the Splice Box. Unscrew the Bolts attaching the arm to the fixture. 3. Insert the wedge between the fixture and Arm. Be sure to place Gasket between fixture and wedge and also between wedge and arm. Replace the bolts to 3/8 -16 Bolts provided with the wedge. Tighten with the bolts. Arm Door Roadway Arm Splice Box Bolts Wedge 4. Placing the wedge as shown the Fig, tilts the fixture by 5 degrees Upwards. To tilt the the fixture in opposite direction, rotate the Wedge by 180 degrees. Gaskets TM RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com SLIPFITTER MOUNTING 1. The Slipfitter fits a 2 3/8” O.D. Pole Tenon. Place the slipfitter over the tenon and secure the fixture with 2 Set Screws on the side of the slipfitter. Fixture Slipfitter Locking Bolt 2. Feed wires from Fixture through slipfitter and supply wires from Pole. Make the necessary connections in the slipfitter and knot wires for strain relief. 3. To adjust the angle of the slipfitter, remove 2 screws and remove the Slipfitter Cover Plate. Loosen the Locking Bolt and swivel fixture to desired angle. The graduation on the slipfitter cover plate can be used as guidelines to adjust the angle. Plug Screws 4. Tighten the Locking Bolt. Replace slipfitter cover plate. Tighten Screws. Set screws Slipfitter cover plate Pole Tenon 5. Seal Plug using Teflon tape or silicone sealant. FIXTURE WIRING Universal voltage driver permits operation at 120 to 277VAC, 50 or 60Hz. Units ordered with (/480V) suffix are 480V, 50Hz or 60Hz. Factory ordered fixtures with suffix (/PCS) are120V swivel photocell and (/PCS2) are 277V swivel photocell. 6kV surge protector for 120 to 277VAC, 50 or 60Hz provided with the fixture. Wire the surge protector in the pole handle away from the fixture and at least 6” above ground. 1. Connect the black fixture lead to the (+) LINE supply lead and black surge protector wire. 2. Connect the white fixture lead to the (-) COMMON supply lead and white surge protector wire. 3. Connect the bare copper Ground wire from fixture to supply ground and green surge protector wire. SURGE PROTECTOR ACCESSORIES Wedge can be ordered with WEDGERW-A Bronze Wedge WEDGERW-W White Wedge WEDGERW-RG Roadway Gray Wedge Fixtures with Roadway arm can be provided with 120V -277V twist lock photocell (/PCT) CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. 1. Clean glass lens with non-abrasive glass cleaning solution. 2. Do not open fixture to clean the LED. Do not touch the LED. TROUBLESHOOTING 1. Check that the line voltage at fixture is correct. Refer to wiring directions. 2. Is the fixture grounded properly? 3. Is the photocell functioning properly (if used)? TM RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com 0-10V DIMMABLE WIRING PHOTOCELL INSTALLATION Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming, follow the wiring directions as in fig. 2. 1. Connect the black fixture lead to the (+) LINE supply lead. 2. Connect the white fixture lead to the (-) COMMON supply lead. 3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output. 4. Connect the purple fixture lead to the (V+) DIM lead. 5. Connect the gray fixture lead to the (V-) DIM lead. 6. Cap the yellow fixture lead, if present. Do NOT connect. Photocell may be installed in the field. Apply weatherproof silicone sealant to all plugs and unused conduit entries. 1. Remove close up plug on top of the wall mounting box. 2. Install photocell and wire as per diagram. 3. Use photocell rated for your supply voltage. BLACK “COM” WHITE LIGHT WP2FC FIXTURE PHOTOCELL PHOTOCELL Fig. 2 Patent: US: pat. D668,370; CN: ZL201230100154.X; MX: 38423; TW: pat. D156973; CA: D RAB Lighting Inc. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. Easy Installation & Product Help ©2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA RWLED-IN-0914 Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.5-c014 79.151481, 2013/03/13-12:09:15 Create Date : 2014:09:17 11:03:03-04:00 Metadata Date : 2014:09:17 11:03:09-04:00 Modify Date : 2014:09:17 11:03:09-04:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:b6354180-da39-4377-a23f-d49e15a47a49 Original Document ID : adobe:docid:indd:e9936599-faab-11dc-9862-89a8683bb236 Document ID : xmp.id:8d94e282-87c6-af4e-9e03-a52a69f4fd58 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:b9a4ed98-bf7f-c347-9b2e-193b4892fc3a Derived From Document ID : xmp.did:b9a4ed98-bf7f-c347-9b2e-193b4892fc3a Derived From Original Document ID: adobe:docid:indd:e9936599-faab-11dc-9862-89a8683bb236 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:09:17 11:03:03-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 3 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools