RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com

IMPORTANT

ROADWAY

SLIPFITTER

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
Arm cover plate
Screw

Roadway Arm

ROADWAY ARM MOUNTING

Splice Box

1.	 The Roadway Arm fits a 1”, 1.25”, 1.5” and 2” pole tenon.
Cap

2.	 Slide the Fixture on the pole tenon. Unlatch the Arm
Door and place the appropriate Pole Mounting Clamp
in the Arm. The tenon diameter is marked on the pole
mounting clamp.
3.	 Secure the fixture on the pole by tightening the pole
mounting clamp with the hardware provided.
4.	 Open the Arm Cover Plate to the Splice Box. Feed wires
from Pole and fixture into the splice box. Make the
necessary connections in the splice box and knot wires
for strain relief.

Pole Mounting Clamp
Fixture

5.	 Install the arm cover plate. Be sure the gasket and o-ring
are in place. Tighten Screws, install the Cap and close the
arm door.

WEDGE MOUNTING

Bolt

1.	 To tilt the fixture use the Wedge with hardware provided.

Arm cover
plate

2.	 Open the Arm Cover Plate to the Splice Box. Unscrew
the Bolts attaching the arm to the fixture.
3.	 Insert the wedge between the fixture and Arm. Be sure to
place Gasket between fixture and wedge and also
between wedge and arm. Replace the bolts to 3/8 -16
Bolts provided with the wedge. Tighten with the bolts.

Arm
Door

Roadway Arm
Splice Box
Bolts
Wedge

4.	 Placing the wedge as shown the Fig, tilts the fixture by 5
degrees Upwards. To tilt the the fixture in opposite direction, rotate the Wedge by 180 degrees.
Gaskets

TM

RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com

SLIPFITTER MOUNTING

1.	 The Slipfitter fits a 2 3/8” O.D. Pole Tenon. Place the
slipfitter over the tenon and secure the fixture with 2 Set
Screws on the side of the slipfitter.

Fixture

Slipfitter
Locking Bolt

2.	 Feed wires from Fixture through slipfitter and supply
wires from Pole. Make the necessary connections in the
slipfitter and knot wires for strain relief.
3.	 To adjust the angle of the slipfitter, remove 2 screws and
remove the Slipfitter Cover Plate. Loosen the Locking
Bolt and swivel fixture to desired angle. The graduation
on the slipfitter cover plate can be used as guidelines to
adjust the angle.

Plug

Screws

4.	 Tighten the Locking Bolt. Replace slipfitter cover plate.
Tighten Screws.

Set
screws

Slipfitter
cover
plate

Pole Tenon

5.	 Seal Plug using Teflon tape or silicone sealant.

FIXTURE WIRING

Universal voltage driver permits operation at 120 to
277VAC, 50 or 60Hz. Units ordered with (/480V) suffix are
480V, 50Hz or 60Hz. Factory ordered fixtures with suffix
(/PCS) are120V swivel photocell and (/PCS2) are 277V swivel
photocell. 6kV surge protector for 120 to 277VAC, 50 or
60Hz provided with the fixture. Wire the surge protector in
the pole handle away from the fixture and at least 6” above
ground.
1.	 Connect the black fixture lead to the (+) LINE supply
lead and black surge protector wire.
2.	 Connect the white fixture lead to the (-) COMMON
supply lead and white surge protector wire.
3.	 Connect the bare copper Ground wire from fixture to
supply ground and green surge protector wire.

SURGE
PROTECTOR

ACCESSORIES

Wedge can be ordered with
	
WEDGERW-A Bronze Wedge
	
WEDGERW-W White Wedge
	
WEDGERW-RG Roadway Gray Wedge
Fixtures with Roadway arm can be provided with
	
120V -277V twist lock photocell (/PCT)

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough
to touch. Do not clean or maintain while fixture is
energized.
1.	 Clean glass lens with non-abrasive glass cleaning
solution.
2.	 Do not open fixture to clean the LED. Do not touch the
LED.

TROUBLESHOOTING

1.	 Check that the line voltage at fixture is correct. Refer to
wiring directions.
2.	 Is the fixture grounded properly?
3.	 Is the photocell functioning properly (if used)?

TM

RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com

0-10V DIMMABLE WIRING

PHOTOCELL INSTALLATION

Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. For 0-10V Dimming, follow the wiring directions
as in fig. 2.
1.	 Connect the black fixture lead to the (+) LINE supply lead.
2.	 Connect the white fixture lead to the (-) COMMON supply
lead.
3.	 Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to
the output.
4.	 Connect the purple fixture lead to the (V+) DIM lead.
5.	 Connect the gray fixture lead to the (V-) DIM lead.
6.	 Cap the yellow fixture lead, if present. Do NOT connect.

Photocell may be installed in the field. Apply weatherproof
silicone sealant to all plugs and unused conduit entries.
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
BLACK

“COM”
WHITE

LIGHT

WP2FC
FIXTURE

PHOTOCELL

PHOTOCELL

Fig. 2

Patent: US: pat. D668,370; CN: ZL201230100154.X; MX: 38423; TW: pat. D156973; CA: D RAB Lighting Inc.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.

Easy Installation & Product Help
©2014 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

RWLED-IN-0914

Tech Help Line
Call our experts 888 RAB-1000

rabweb.com
Visit our website for product info

email
Answered promptly sales@rabweb.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.5-c014 79.151481, 2013/03/13-12:09:15
Create Date                     : 2014:09:17 11:03:03-04:00
Metadata Date                   : 2014:09:17 11:03:09-04:00
Modify Date                     : 2014:09:17 11:03:09-04:00
Creator Tool                    : Adobe InDesign CC (Windows)
Instance ID                     : uuid:b6354180-da39-4377-a23f-d49e15a47a49
Original Document ID            : adobe:docid:indd:e9936599-faab-11dc-9862-89a8683bb236
Document ID                     : xmp.id:8d94e282-87c6-af4e-9e03-a52a69f4fd58
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:b9a4ed98-bf7f-c347-9b2e-193b4892fc3a
Derived From Document ID        : xmp.did:b9a4ed98-bf7f-c347-9b2e-193b4892fc3a
Derived From Original Document ID: adobe:docid:indd:e9936599-faab-11dc-9862-89a8683bb236
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC (Windows)
History Changed                 : /
History When                    : 2014:09:17 11:03:03-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 3
Creator                         : Adobe InDesign CC (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu