RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TM
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
ROADWAY ARM MOUNTING
1. The Roadway Arm ts a 1”, 1.25”, 1.5” and 2” pole tenon.
2. Slide the Fixture on the pole tenon. Unlatch the Arm
Door and place the appropriate Pole Mounting Clamp
in the Arm. The tenon diameter is marked on the pole
mounting clamp.
3. Secure the xture on the pole by tightening the pole
mounting clamp with the hardware provided.
4. Open the Arm Cover Plate to the Splice Box. Feed wires
from Pole and xture into the splice box. Make the
necessary connections in the splice box and knot wires
for strain relief.
5. Install the arm cover plate. Be sure the gasket and o-ring
are in place. Tighten Screws, install the Cap and close the
arm door.
ROADWAY SLIPFITTER
WEDGE MOUNTING
1. To tilt the xture use the Wedge with hardware provided.
2. Open the Arm Cover Plate to the Splice Box. Unscrew
the Bolts attaching the arm to the xture.
3. Insert the wedge between the xture and Arm. Be sure to
place Gasket between xture and wedge and also
between wedge and arm. Replace the bolts to 3/8 -16
Bolts provided with the wedge. Tighten with the bolts.
4. Placing the wedge as shown the Fig, tilts the xture by 5
degrees Upwards. To tilt the the xture in opposite direc-
tion, rotate the Wedge by 180 degrees.
Arm cover
plate
Roadway Arm
Splice Box
Wedge
Gaskets
Bolts
Arm
Door
Roadway Arm
Bolt
Fixture
Pole Mount-
ing Clamp
Screw
Cap
Arm cover plate
Splice Box
RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TM
SLIPFITTER MOUNTING
1. The Sliptter ts a 2 3/8” O.D. Pole Tenon. Place the
sliptter over the tenon and secure the xture with 2 Set
Screws on the side of the sliptter.
2. Feed wires from Fixture through sliptter and supply
wires from Pole. Make the necessary connections in the
sliptter and knot wires for strain relief.
3. To adjust the angle of the sliptter, remove 2 screws and
remove the Sliptter Cover Plate. Loosen the Locking
Bolt and swivel xture to desired angle. The graduation
on the sliptter cover plate can be used as guidelines to
adjust the angle.
4. Tighten the Locking Bolt. Replace sliptter cover plate.
Tighten Screws.
5. Seal Plug using Teon tape or silicone sealant.
Set
screws
Pole Tenon
Locking Bolt
Fixture
Sliptter
Screws
Plug
Sliptter
cover
plate
FIXTURE WIRING
Universal voltage driver permits operation at 120 to
277VAC, 50 or 60Hz. Units ordered with (/480V) sux are
480V, 50Hz or 60Hz. Factory ordered xtures with sux
(/PCS) are120V swivel photocell and (/PCS2) are 277V swivel
photocell. 6kV surge protector for 120 to 277VAC, 50 or
60Hz provided with the xture. Wire the surge protector in
the pole handle away from the xture and at least 6” above
ground.
1. Connect the black xture lead to the (+) LINE supply
lead and black surge protector wire.
2. Connect the white xture lead to the (-) COMMON
supply lead and white surge protector wire.
3. Connect the bare copper Ground wire from xture to
supply ground and green surge protector wire.
SURGE
PROTECTOR
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough
to touch. Do not clean or maintain while xture is
energized.
1. Clean glass lens with non-abrasive glass cleaning
solution.
2. Do not open xture to clean the LED. Do not touch the
LED.
TROUBLESHOOTING
1. Check that the line voltage at xture is correct. Refer to
wiring directions.
2. Is the xture grounded properly?
3. Is the photocell functioning properly (if used)?
ACCESSORIES
Wedge can be ordered with
WEDGERW-A Bronze Wedge
WEDGERW-W White Wedge
WEDGERW-RG Roadway Gray Wedge
Fixtures with Roadway arm can be provided with
120V -277V twist lock photocell (/PCT)
RWLED ROADWAY 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TM
Fig. 2
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. For 0-10V Dimming, follow the wiring directions
as in g. 2.
1. Connect the black xture lead to the (+) LINE supply lead.
2. Connect the white xture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from xture to supply ground.
Do NOT connect the GROUND of the dimming xture to
the output.
4. Connect the purple xture lead to the (V+) DIM lead.
5. Connect the gray xture lead to the (V-) DIM lead.
6. Cap the yellow xture lead, if present. Do NOT connect.
PHOTOCELL INSTALLATION
Photocell may be installed in the eld. Apply weatherproof
silicone sealant to all plugs and unused conduit entries.
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
“COM”
PHOTOCELL
WP2FC
BLACK
WHITE
PHOTOCELL
LIGHT
FIXTURE
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2014 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
Patent: US: pat. D668,370; CN: ZL201230100154.X; MX: 38423; TW: pat. D156973; CA: D RAB Lighting Inc.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.
RWLED-IN-0914