Table of Contents Section 11 Obsolescent and Obsolete Circuit Breakers Obsolescent and Obsolete Types Circuit Breaker Availability Pictorial and Dimensions 11-2 11-4—11-5 Obsolescent Circuit Breakers F-Frame Thermal-Magnetic Circuit Breakers 11-6 K-Frame Thermal-Magnetic Circuit Breakers 11-7 Mag-Gard™ Motor Circuit Protector 11-8 11-9—11-10 UL Listed Marine Circuit Breakers 11-11 Circuit Breakers for NQO, NQOB and NQOD Panelboards, Branch Circuit Breakers and Mounting Assemblies for ML Panelboards 11-12 Rating Plugs For Obsolete Electronic Trip Circuit Breakers 11-13 EH/EHB Circuit Breakers 11-14 FJA Thermal-Magnetic Circuit Breakers 11-15 QE Metering Circuit Breakers 11-16 KD/KG Thermal-Magnetic Circuit Breakers 11-17 NHL Thermal-Magnetic Molded Case Circuit Breaker 11-18 SE Circuit Breaker with Full-Function Trip Unit 11-19 SE Circuit Breaker Accessories 11-20 M-frame Thermal-Magnetic Circuit Breakers 11-21 Field-Installable Accessories 11-22 Mechanical Lug Information 11-23 Micrologic™ Series 2/3/A/B Trip Unit Test Sets 11-24 Micrologic™ Add-On Ground-Fault Module (GFM) 11-25 Masterpact™ M/MP/MC Circuit Breakers, UL 489/1066 Listed 11-26 Masterpact™ M/MP/MC Circuit Breaker Control Units OBSOLETE CIRCUIT BREAKERS Automatic Molded-Case Switches 11-27 11-28—11-29 Masterpact™ M/MP/MC Circuit Breaker Spare Parts 11-30 11 Masterpact™ M/MP/MC Circuit Breaker Accessories © 2012 Schneider Electric All Rights Reserved 11-1 Obsolescent and Obsolete Types Table 11.1: Circuit Breaker Availability Class 600 www.schneider-electric.us Circuit Breaker Availability Availability Series of Cat. No. Frame Size 115A–130A MO-1 (Add-on) Volts Poles Amperes Obsolete No Longer Available 120 Vac 1 15–30 Obsolescent X 215A–250A MO-2 (Add-on) 120/240 Vac 2 15–50 X 215B–250B MO-2B (Add-on) 120/240 Vac 2 S.P. 15–50 X 70000 Multi-Breaker 120 Vac 4 S.P. 15–50 X 111600 MO-2 120/240 Vac 2 15–30 X 131600 MO-2 120/240 Vac 2 15–30 X 151101 MO-1 120 Vac 1 15–30 X 151600 MO-2 120/240 Vac 2 15–30 X 161101 MO-1 120 Vac 1 With SN 15–30 X X 161600 MO-2 120/240 Vac 2 With SN 15–30 161700 MO-2 120/240 Vac 2 S.P. 15–30 X 260000 MB (Left-hand) 120 Vac 4 S.P. 15–50 X 270000 MB (Right-hand) 120 Vac 4 S.P. 15–50 X 460000 MO-8 120/240 Vac 4 S.P. 15–50 X 470000 MO-4 120/240 Vac 4 S.P. 15–40 X 480000 MO-4 (Plug-in) 120/240 Vac 4 S.P. 15–50 X 940000 LM 600 Vac 2-3 125–800 X 950000 50 A Form W 250 Vac 1, 2, 3 15–50 X 951000 50 A Form W 250 Vac 2, 3 15–50 X 952000 50 A Form W 250 Vac 2, 3 15–50 X 953000 Flip-on Form W 230 Vac 1, 2, 3 15–50 X 954000 100 A Form W (Trip Unit) 250 Vac 2, 3 50–100 X 955000 100 A Form W 250 Vac 2, 3 50–100 X 956000 225 A Form W 250 Vac 2, 3 70–225 X 957000 400 A (KL) Form W 250 Vac 2, 3 125–400 X 958000 600 A (WL) Form W 250 Vac 2, 3 225–600 X 959000 KL Frame Only 600 Vac 2, 3 125–400 X 961000 50 A Form W 600 Vac 2, 3 15–50 X 962000 50 A Form W 600 Vac 2, 3 15–50 X 964000 100 A Form W 600 Vac 2, 3 50–100 X 965000 100 A Form W 600 Vac 2, 3 50–100 X 966000 225 A Form W 600 Vac 2, 3 70–225 X 11 967000 400 A (KL) Form W 600 Vac 2, 3 125–400 X 968000 600 A (WL) Form W 600 Vac 2, 3 225–600 X X OBSOLETE CIRCUIT BREAKERS 970000 Type L Form W 240 Vac 1, 2, 3 10–50 971000 Type L Form W (Flip-on) 240 Vac 1, 2, 3 10–50 X 972000 M1 (Bolt-on) 240 Vac 2, 3 15–70 X 973000 M2 (Bolt-on) 240 Vac 2, 3 50–100 X 974000 MM (M) (Bolt-on) 120/240 Vac 2 S.P. 15–50 X 975000 100 A Trip Unit 250 Vac 2, 3 50–100 X 976000 225 A Trip Unit 250 Vac 2, 3 70–225 X 977000 KL Trip Unit 600 Vac 2, 3 125–400 X 978000 LM Trip Unit 600 Vac 2, 3 225–800 X 979000 WL Frame 600 Vac 2, 3 225–600 X 982000 50 A Form W (Flip-on) 125/250 Vac 1, 2, 3 15–50 X 984000 ML-2 250 Vac 2, 3 50–100 X 985000 100 A (G) Form W 600 Vac 2, 3 50–100 X 986000 100 A (F) Form W 600 Vac 2, 3 10–100 X 987000 ML-3 250 Vac 2, 3 125–225 X 988000 ML-1 250 Vac 2, 3 15–100 X 989000 ML-1 480 Vac 2, 3 15–100 X 991000 QB 120/240 Vac 1 15–50 X 992000 ML 120/240 Vac 1, 2, 3 10–50 X 992900 ML Form Y 277 Vac 1 10–20 X 994000 ML-2 600 Vac 2, 3 15–100 X 995000 100 A (G) Form W 600 Vac 2, 3 15–100 X 996000 100 A (F) Form W 600 Vac 2, 3 15–100 X 997000 ML-3 600 Vac 2, 3 50–225 X 998000 ML-1 600 Vac 2, 3 15–100 X 999000 ML-1 600 Vac 2, 3 15–100 X A1B 100 A 120/240 Vac 1, 2, 3 15–100 X EH, EHB 100 A 480Y/277 Vac 1, 2, 3 15–100 EH See page 11-14 FC 100 A 480 Vac 2, 3 15–100 FC See page 11-5 FD, FG, FJ 100 A 480Y/277 Vac 1, 2, 3 15–100 X GJL / NENL 100 A 480 Vac 3 15–100 X KA, KH, KC 250 A 480 Vac 2, 3 70–250 X See pgs. 11-6–11-8 Contact your local Sales Office for availability. 11-2 © 2012 Schneider Electric All Rights Reserved Obsolescent and Obsolete Types Circuit Breaker Availability Class 600 www.schneider-electric.us Circuit Breaker Availability. Continued Availability Series of Cat. No. Frame Size FI, FIL 100 A 480 Vac 2, 3 20–100 X KI, KIL 225 A 480 Vac 2, 3 110–225 X LI, LIL 400 A 480 Vac 2, 3 300–400 X KD, KG 250 A 240 Vac 2, 3 100–250 KG LA(JKL) 0000 400 A 600 Vac 2, 3 125–400 X X Volts Poles Amperes Obsolete No Longer Available MA-0000 1000 A 600 Vac 2, 3 125–1000 Masterpact M/MP/MC 6300 A 600 Vac 3, 4 800–6300 MEC 225 A 600 Vac 2, 3 100–225 Obsolescent See page 11-17 See pgs. 11-27–11-30 X MEC 400 A 600 Vac 2, 3 250–400 X MEC 800 A 600 Vac 2, 3 400–800 X MHAB, BC, CA MM (Plug-on) 120/240 Vac 2 S.P. 15–50 X MHAB, BC, CA M1 (Plug-on) 120/240 Vac 2, 3 15–70 X MHAB, BC, CA M2 (Plug-on) 120/240 Vac 2, 3 70–100 X NHL 1200 A 480 Vac 2, 3 800–1200 PEC 1200 A 600 Vac 2, 3 600–1200 See page 11-18 X PEC 1600 A 600 Vac 2, 3 1000–1600 X PEC 2000 A 600 Vac 2, 3 1000–2000 X QOT Series 1 120/240 Vac 1, 2 30 X Q1, Q1B 150 A 120/240 Vac 1, 2 15–100 X Q1, Q1B 150 A 240 Vac 3 15–100 X Q1-H, Q1B-H 100 A 240 Vac 2 15–100 X Q1-VH, Q1B-VH 125 A 120/240 Vac 2 15–30 X Q1-VH, Q1B-VH 100 A 240 Vac 3 15–30 X X Q2, Q2-H, Q2H 225 A 240 Vac 2, 3 100–225 QE 200 A 120/240 Vac 2, 3 70–200 SE 4000 A 600 Vac 3 200–4000 CK 1200 A 480 Vac 3 400–1200 CM 2000 A 480 Vac 3 1250–2000 X XO 50 A 120/240 Vac 1, 2 15–50 X See page 11-16 See pgs. 11-20 X Y1B 100 A 277 Vac 1 15–100 X ME, MEL 250 A, 400 A, 800 A 600 Vac 3 100–800 X MX, MXL 250 A, 400 A, 800 A 600 Vac 3 100–800 X NA, NAL 1200 A 600 Vac 3 600–1200 X NC, NCL 1200 A 600 Vac 3 600–1200 X NX, NXL 1200 A 600 Vac 3 600–1200 X NE, NEL 1200 A 600 Vac 3 600–1200 X PAF 2000 A 600 Vac 3 600–2000 X PHF 2000 A 600 Vac 2, 3 600–2000 X PCF 2500 A 600 Vac 2, 3 1600–2500 X PXF 2500 A 600 Vac 2, 3 600–2500 X PEF 2500 A 600 Vac 3 600–2500 X OBSOLETE CIRCUIT BREAKERS Table 11.2: 11 Contact your local Sales Office for availability. © 2012 Schneider Electric All Rights Reserved 11-3 Obsolescent and Obsolete Types Pictorial and Dimensions Class 600 LIL LA (W) www.schneider-electric.us MA (W) ML-2 ML-1 Table 11.3: Circuit Breaker Dimensions Dimensions Circuit Breaker Type Cat. No. Prefix QB ML-1 ML-2 ML-3 LA (W) MA (W) KL 991 992 992 992 999 994 997 LA MA 967 LM FIL (4) KIL (4) LIL NHL 940 IFL IKL ILL NHL ML Number Poles A B C D E F G H 11 OBSOLETE CIRCUIT BREAKERS in. mm in. mm in. mm in. mm in. mm in. m m in. mm in. mm 1 1 2 3 2&3 2&3 2&3 2&3 2&3 2&3 3.75 6.00 6.00 6.00 6.50 9.56 10.38 10.75 16.00 22.00 95 152 152 152 165 243 264 273 406 559 1.00 1.00 2.00 3.00 4.47 4.47 5.97 8.25 8.25 8.25 25 25 51 76 113 113 152 209 209 209 2.50 3.09 3.09 3.09 3.06 3.75 3.88 4.31 4.06 5.50 63 78 78 78 78 95 98 109 103 140 3.06 3.91 3.91 3.91 3.94 4.88 5.31 5.50 6.06 7.00 78 99 99 99 100 124 135 140 154 178 — .88 .88 .88 .94 1.69 1.69 .63 .88 .63 — 22 22 22 24 43 43 16 22 16 — 4.25 4.25 4.25 4.25 6.50 6.63 9.50 14.25 20.75 — 108 108 108 108 165 168 241 362 527 — — — — 1.50 1.50 2.00 2.75 2.75 2.75 — — — — 38 38 51 70 70 70 — .33 .19 1.83 .75 .75 1.00 1.38 1.38 1.38 — 8 5 46 19 19 25 35 35 35 2&3 2&3 2&3 2&3 2&3 22.00 8.29 11.00 11.00 20.00 559 210 279 279 508 8.25 4.46 6.00 12.00 12.00 209 113 152 305 305 5.50 3.67 4.02 4.05 5.75 140 93 102 103 146 7.00 4.70 5.51 6.11 8.12 178 119 140 155 206 .63 .44 .88 .88 5.87 16 11 22 22 149 20.75 7.41 9.25 9.25 7.76 527 188 235 235 197 2.75 1.50 2.00 4.00 4.00 70 38 51 102 102 1.38 .75 1.00 2.00 2.00 35 19 25 51 51 B G E A 11-4 H D H C F © 2012 Schneider Electric All Rights Reserved Obsolescent and Obsolete Types Pictorial and Dimensions Class 600 www.schneider-electric.us Figure 1 Figure 3 EH, EHB Figure 4 D A A B E B E E C A G HH E B C/L C/L B E D C A F A F E E B Figure 6 B G HH E B E C/L A F A F E C D E Table 11.4: E B Circuit Breaker Cat. No. Prefix Fig. No. A B C D E F G H 1 2 3 1 2, 3 2 3 1 2 3 1.00 2.00 3.00 3.50 3.50a 3.50a 2.00 2.00 2.00 2.44 2.44 2.44 — — — — — — — — — 4 5 6.44 6.44 3.00 4.50 3.16 3.16 2.97 2.97 2.97 Width 1.50 Width 3.00 3.92 3.92 b b 4.25 4.25 — 1.50 — 0.75 2, 3 2&3 6 7 4.12 14.75 7.35 9.00 3.20 4.37 4.17 6.50 3.34 1.66 — 11.43 — 3.00 — 1.50 2&3 8 12.12 14.98 6.40 8.07 1.69 8.75 5.00 — 1 9 6.00 1.50 3.16 3.16 FCL 2 10 6.00 3.00 c 3 11 6.00 4.50 3.16 MAL, MHL 2&3 8 14.00 9.00 4.53 NA, NC, NX, NE 2&3 8 12.12 14.98 6.40 PA, PH, PX, PE 2&3 12 20.06 13.70 7.25 PC, PX-25, PE-20-25 2 & 3 13 26.10 23.30 13.33 a 70–100 A is 4.00 in. b Dimensions E are 1.59 in at ON end and 0.63 in at OFF end. c FCL 2-pole circuit breaker dimension B is 4.50 as in Fig. 23. 4.13 4.13 4.13 6.50 8.07 10.47 16.55 0.44 0.44 0.44 1.66 1.69 14.00 14.10 5.13 5.13 5.13 10.69 8.75 12.00 12.00 1.50 — 1.50 3.00 5.0 12.75 — — — 0.75 1.50 — — — EH, EHB FDA, FGA, FJA E Q2L, Q2L-H B G HH E D C C/L A F E B G F D C KD, KG MXL, MEL NAL, NCL, NEL, NXL Table 11.5: A E B G F Dimensions—In. No. Poles C/L A F Circuit Breaker Dimensions D Frame Size Approx. Shipping Weight (Lbs.) MAL MHL PAF PHF PXF PEF 34 69 80 C E © 2012 Schneider Electric All Rights Reserved OBSOLETE CIRCUIT BREAKERS A A D C 11 E B G D C 11-5 Obsolescent Circuit Breakers F-Frame Thermal-Magnetic Circuit Breakers Class 650 www.schneider-electric.us FC circuit breakers are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. Thermal-magnetic molded case circuit breakers shown on page 11-6 are permanent trip UL Listed, CSA® Certified, IEC rated, and also meet the requirements of Federal Specification W–C–375B/GEN as indicated on Digest pages 7-4 through 7-7. NOTE: Consider using PowerPact™ circuit breakers for situations requiring circuit breaker accessories. See Digest Section 7 for more information. FAL/FHL 2P 15–100 A Table 11.6: F-Frame—100 A, Thermal-Magnetic, Individually-Mounted, 480 Vac Extra-High Interrupting Fixed AC Magnetic Trip Ampere Rating Hold 275 A 275 A 275 A 275 A 400 A 400 A 400 A 400 A 800 A 800 A 800 A 900 A 900 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A FAL/FHL 3P 15–100 A Table 11.7: Trip 600 A 600 A 600 A 600 A 850 A 850 A 850 A 850 A 1450 A 1450 A 1450 A 1700 A 1700 A 2P 3P Terminal 480 Vac, 250 Vdc 480 Vac, 250 Vdc Wire Range (AWG) Cat. No. Cat. No. — FCL34015 — FCL34020 CU30FA4 (1) 14–10 Cu — FCL34025 — FCL34030 — FCL34035 — FCL34040 — FCL34045 FCL24050 FCL34050 AL100FA4 FCL24060 FCL34060 (1) 14–3 Cu or (2) 12–1 Al FCL24070 FCL34070 FCL24080 FCL24090 FCL24100 FCL34080 FCL34090 FCL34100 Interrupting Ratings FAL Voltage 240 Vac 480 Vac 600 Vac 240 Vac 480 Vac 600 Vac 10 kA — — 18 kA (1P), 25 kA (2P, 3P) 18 kA — 25 kA 18 kA 14 kA Termination Option FHL FCL FIL 25 kA (1P) 65 kA (2P, 3P) 25 kA (2P, 3P) 18 kA (2P, 3P) 100 kA 65 kA — 200 kA 200 kA 100 kA For factory-installed termination, place 11 Termination Letter termination letter in the third block of the F = No Lugs circuit breaker catalog number. L = Lugs both ends FAL36100 P with MT Suffix = Lugs ON end Termination Letter P = Lugs OFF end FA 2P 3 in. (76 mm) Mounting Height OBSOLETE CIRCUIT BREAKERS Table 11.8: F-Frame—100 A, Thermal-Magnetic, I-Line™ Construction, 480 Vac Extra-High Interruptingc Ampere Rating FA 3P 4.5 in. (114 mm) Mounting Height Table 11.9: 1P A B C FA14035A FA14035B FA14035C ABC CBA 2Pa 3P 480 Vac, 250 Vdcb 480 Vac, 250 Vdcc Terminal Wire Range (AWG) Hold Trip Cat. No. Cat. No. 15 A 275 A 600 A — FC34015 20 A 275 A 600 A — FC34020 CU30FA4 (1) 14–10 Cu 25 A 275 A 600 A — FC34025 30 A 275 A 600 A — FC34030 35 A 400 A 850 A — FC34035 40 A 400 A 850 A — FC34040 45 A 400 A 850 A — FC34045 50 A 400 A 850 A FC24050( ) FC34050 AL100FA4 60 A 800 A 1450 A FC24060( ) FC34060 (1) 14–3 Cu or (1) 12–1 Al 70 A 800 A 1450 A FC24070( ) FC34070 80 A 800 A 1450 A FC24080( ) FC34080 90 A 900 A 1700 A FC24090( ) FC34090 100 A 900 A 1700 A FC24100( ) FC34100 a 1P and 2P circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix. See Phase Option Table. b FCL 2P circuit breakers are built using 3P module. c FCL circuit breakers are not rated for 250 Vdc. Phase Options Phase Option Letter AB AC BC Fixed AC Magnetic Trip 2P Table 11.10: 3P Voltage 240 Vac 277 Vac 480 Vac 600 Vac FA24030AB FA24030AC FA24030BC Interrupting Ratings FA 240 Vac 10 kA — — — 480 Vac 18 kA (1P), 25 kA (2P, 3P) 18 kA 18 kA — 600 Vac 25 kA — 18 kA 14 kA FH FC FI 25 kA (1P) 65 kA (2P, 3P) — 25 kA (2P, 3P) 18 kA (2P, 3P) 100 kA 65 kA 65 kA — 200 kA — 200 kA 100 kA FA34030 FA34030CBA Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-28 OptionalLugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-23 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-5 Enclosures: see Digest Section 7 11-6 DE2 Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers K-Frame Thermal-Magnetic Circuit Breakers Class 655, 825, 660 www.schneider-electric.us K-frame circuit breakers are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. High Standard Interrupting Cat. No. High Interrupting Cat. No. Extra-High Interruptingb Cat. No. Terminal Wire Range 2P, 600 Vac, 250 Vdc 70 350 A 80 400 A 90 450 A 100 500 A 110 550 A 125 625 A 150 750 A 175 875 A 200 1000 A 225 1125 A 250 1250 A 700 A 800 A 900 A 1000 A 1100 A 1250 A 1500 A 1750 A 2000 A 2250 A 2500 A KAL26070 KAL26080 KAL26090 KAL26100 KAL26110 KAL26125 KAL26150 KAL26175 KAL26200 KAL26225 KAL26250 KHL26070 KHL26080 KHL26090 KHL26100 KHL26110 KHL26125 KHL26150 KHL26175 KHL26200 KHL26225 KHL26250 — — — — KCL24110 KCL24125 KCL24150 KCL24175 KCL24200 KCL24225 KCL24250 AL250KA (1) 4 AWG–350 kcmil Al 3P, 600 Vac, 250 Vdc 70 350 A 80 400 A 90 450 A 100 500 A 110 550 A 125 625 A 150 750 A 175 875 A 200 1000 A 225 1125 A 250 1250 A 700 A 800 A 900 A 1000 A 1100 A 1250 A 1500 A 1750 A 2000 A 2250 A 2500 A KAL36070 KAL36080 KAL36090 KAL36100 KAL36110 KAL36125 KAL36150 KAL36175 KAL36200 KAL36225 KAL36250 KHL36070 KHL36080 KHL36090 KHL36100 KHL36110 KHL36125 KHL36150 KHL36175 KHL36200 KHL36225 KHL36250 — — — — KCL34110 KCL34125 KCL34150 KCL34175 KCL34200 KCL34225 KCL34250 AL250KA (1) 4 AWG–350 kcmil Al Low Table 11.12: Ampere Rating K-Frame—250A, Thermal-Magnetic, I-Line™ Construction, 600 Vac Adjustable AC Magnetic Tripa Low Standard Interrupting Cat. No. High High Interrupting Cat. No. Extra-High Interruptingb Cat. No. Terminal Wire Range 2P, 600 Vac, 250 Vdcc 70 350 A 700 A KA26070( ) KH26070( ) — 80 400 A 800 A KA26080( ) KH26080( ) — 90 450 A 900 A KA26090( ) KH26090( ) — 100 500 A 1000 A KA26100( ) KH26100( ) — 110 550 A 1100 A KA26110( ) KH26110( ) KC24110( ) AL250KA 125 625 A 1250 A KA26125( ) KH26125( ) KC24125( ) (1) 4 AWG–350 kcmil Al 150 750 A 1500 A KA26150( ) KH26150( ) KC24150( ) 175 875 A 1750 A KA26175( ) KH26175( ) KC24175( ) 200 1000 A 2000 A KA26200( ) KH26200( ) KC24200( ) 225 1125 A 2250 A KA26225( ) KH26225( ) KC24225( ) 250 1250 A 2500 A KA26250( ) KH26250( ) KC24250( ) 3P, 600 Vac, 250 Vdc 70 350 A 700 A KA36070 KH36070 — 80 400 A 800 A KA36080 KH36080 — 90 450 A 900 A KA36090 KH36090 — 100 500 A 1000 A KA36100 KH36100 — 110 550 A 1100 A KA36110 KH36110 KC34110 AL250KA 125 625 A 1250 A KA36125 KH36125 KC34125 (1) 4 AWG–350 kcmil Al 150 750 A 1500 A KA36150 KH36150 KH34150 175 875 A 1750 A KA36175 KH36175 KC34175 200 1000 A 2000 A KA36200 KH36200 KC34200 225 1125 A 2250 A KA36225 KH36225 KC34225 250 1250 A 2500 A KA36250 KH36250 KC34250 a UL magnetic trip setting tolerances are ±25% for low and ±20% for high from nominal value shown. b KC circuit breakers are 480 Vac c 2P and 3P circuit breaker catalog numbers are completed by adding the required phase connection letters as a suffix. See Phase Option Table. Table 11.13: Voltage 240 Vac 480 Vac 600 Vac Interrupting Ratings KA, KAL 42 kA 25 kA 22 kA Table 11.14: KH, KHL 65 kA 35 kA 25 kA KC, KCL 100 kA 65 kA — KI, KIL 200 kA 200 kA 100 kA Phase Options Phase Option Letter 2P AB AC BC KA26250AB KA26250AC KA26250BC ABC CBA Table 11.15: 3P KA36250 KA36250CBA Walking Beam Mechanical Interlock Componentse Circuit Breaker Prefix Manually Operated Electrically Operated Operator Walking Beam Mounting Pan Cat. Operator Walking Beam Suffix Ass'y. Cat. No. No. Suffix Ass'y. Cat. No. Mounting Pan Cat. No. KAL WB KA4WB KAWBP4 WBMO KA9WB KAWBP9 d Walking Beam Mechanical Interlock requires 2 circuit breakers with WB suffix, 1 walking beam assembly and 1 mounting pan. e Fully enclosed interlocked units are available in Type 1 and Type 3R enclosures, with two neutrals provided in each enclosure. The completely enclosed assembly is not UL Listed. Consult your nearest Schneider Electric local sales office for more information. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-28 OptionalLugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-23 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-5 Enclosures: see Digest Section 7 © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule 11-7 OBSOLETE CIRCUIT BREAKERS Ampere Rating KA/KH/KC 2P and 3P 4.5 in. (114 mm) Mounting Height K-Frame—250 A, Thermal-Magnetic, Individually-Mounted, 600 Vac Adjustable AC Magnetic Tripa 11 Table 11.11: Obsolescent Circuit Breakers Automatic Molded-Case Switches Class 680, 685 www.schneider-electric.us These automatic molded case switches are in obsolescence. Do not use on new applications. Limited service stock is available for replacement or fill purposes. Contact your local Sales Office for product availability. Automatic Molded Case Switches Automatic molded case switches open instantaneously at a factory preset magnetic trip point, calibrated to protect only the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no overload or low level fault protection. Molded case switches open when the handle is switched to the OFF position or in response to an auxiliary tripping device such as a shunt trip. Automatic switches will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers. Automatic molded case switches are UL Listed per UL 489 and are CSA® Certified. Table 11.16: Automatic Molded Case Switches, 600 Vac 2P 3P Withstand Ratingdc Trip Point (A)a Lug Kit Installed Cat. No. Availability Cat. No. Availability 240 Vac 480 Vac 600 Vac 250 Vdc AC DC 100 FHL26000Mb FHL36000Mb 65k 25k 18k 10k 1500 1725 AL100FA 150 — FHL3600015Mb 65k 25k 18k — 2500 — AL150FA 400 LHL26000M LHL36000M 65k 35k 25k 10k 8000 9600 AL400LA 250 KHL26000Mb Not Available KHL36000Mb Not Available 65k 35k 25k 10k 4500 5175 AL250KA 600 MHL260006M Not Available MHL360006M 65k 65k 25k 10k 9000 9900 AL900MA 800 MHL260008M Not Available MHL360008M 65k 65k 25k 10k 9000 9900 AL900MA a UL magnetic trip tolerances are -20% / +30% from the nominal values shown. b FHL and KHL automatic switches will not accept cylinder lock attachments. c The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. d The short circuit current rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. Ampere Rating Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-28 OptionalLugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-23 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-5 11 OBSOLETE CIRCUIT BREAKERS 11-8 DE2 Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers Mag-Gard™ Motor Circuit Protector Class 680, 685 www.schneider-electric.us These Mag-Gard™ motor circuit protectors are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. Mag-Gard™ Motor Circuit Protector Instantaneous trip magnetic only circuit breakers have a single adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard circuit breakers comply with NEC® requirements for providing motor circuit protection when installed as part of a UL Listed combination controller having motor overload protection. Interrupting ratings are established for these UL Recognized Components only when they are used in combination with motor starters with properly sized overload relays and contactors. Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers. Mag-Gard circuit breakers are available with I-Line construction. H-construction Mag-Gard circuit breakers are also available. Table 11.17: Ampere Rating 150 A Magnetic Only 3–1200 A 600 Vac, 50/60 Hz Adjustablea Trip Range Cat. No. 3P only 750–1500 A 400–800 A 750–1500 A 1000–2000 A 1125–2250 A 1250–2500 A KAL3615026M KAL3625021M KAL3625026M KAL 250 A KAL3625030M KAL3625031M KAL3625032M 3A FAL3600311M 8–28 A 7A FAL3600712M 18–70 A 15 A FAL3601513M 50–180 A 30 A FAL3603013M FAL 50–180 A 30 A FAL3603015M 150–580 A 50 A FAL3605016M 150–580 A 100 A FAL3610016M 300–1100 A 100 A FAL3610018M a UL magnetic trip setting tolerances are -20%/+30% from the nominal values shown. Adjustable instantaneous-trip circuit breakers are intended for use in combination with motor starters with overload relays for the protection of motor circuits from short circuits. Other specific applications include rectifiers and resistance welders. These circuit breakers contain a magnetic trip element in each pole with the trip point adjustable from the front. Interrupting ratings are determined by testing the instantaneous-trip circuit breakers in combination with a contactor and overload relay. Select instantaneous-trip circuit breakers as follows: Horsepower 1/2 or less 3/4 to 1-1/2 2 to 3 5 to 25 30 to 125 150 or more Motor Code Letters A–L A–K A–J A–H A–G A–F For other motors order a special thermal-magnetic circuit breaker with magnetic trip settings for the specific motor— specify motor horsepower, voltage, frequency, full-load current and code letter or locked rotor current. 2. 3. 4. 5. 6. Determine motor hp rating from the motor nameplate. Refer to the table at right and select an instantaneous-trip circuit breaker with an Ampere rating recommended for the hp and voltage involved. Select an adjustable trip setting of at least 800%, not to exceed 1300%, of the motor full-load Amperes. (FLA) for other than Design E motors. For Design E motors, select an adjustable trip setting of at least 1100% not to exceed 1700% of FLA. The NEC 1300% maximum setting may be inadequate for instantaneous-trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from “start” to “run,” constant hp multi-speed motors, and motors labeled “high efficiency.” Select thermal-magnetic circuit breakers from Digest page 7-32 for those applications. Part-winding motors, per NEC® 430.3, should have two circuit breakers selected from the above at not more than one half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per NEC 430.103. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-28 OptionalLugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-23 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-5 © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule 11-9 OBSOLETE CIRCUIT BREAKERS Use selection table for motors, other than NEMA Design E, with locked-rotor indicating code letters per NEC® Table 430.7 (b) as follows: 11 1. Obsolescent Circuit Breakers Mag-Gard™ Motor Circuit Protector Class 680, 685 Table 11.18: Adjustable Instantaneous-Trip Circuit Breakers for Single Motor Circuit Protection Hp Ratings of Induction Type Squirrel-Cage and Wound Rotor Motors 3Ø 60 Hz ac 200 V 230 V 460 V Full Load Amperesa Mag-Gard Circuit Breaker Cat. No. 0.8 1 1.1 1.4 1.8 2 2.1 2.3 2.6 2.7 2.8 3.2 3.4 3.6 3.9 4.1 4.8 5.2 6 6.1 6.8 7.6 7.8 9 9.6 11 14 15.2 17 17.5 21 22 25.3 27 28 32 32.2 34 40 41 42 48.3 52 54 62 65 68 92 104 144 150 154 156 177.1 180 192 FAL3600311Ma FAL3600311Ma FAL3600311M FAL3600311M FAL3600311M FAL3600311M FAL3600311M FAL3600311M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3600712M FAL3601513M FAL3601513M FAL3601513M FAL3601513M FAL3601513M FAL3601513M FAL3603015M FAL3603015M FAL3603015M FAL3603015M FAL3603015M FAL3605016M FAL3605016M FAL3605016M FAL3605016M FAL3605016M FAL3605016M FAL3605016M FAL3605016M FAL3610018M FAL3610018M FAL3610018M FAL3610018M FAL3610018M FAL3610018M FAL3610018M FAL3610018M KAL3625025M KAL3625026M KAL3625030M KAL3625030M KAL3625031M KAL3625031M KAL3625032M KAL3625032M KAL3625032M 575 V 1/2 1/2 3/4 1 3/4 1 1/2 1-1/2 1/2 1-1/2 2 3/4 3/4 2 1 3 1 3 1-1/2 1-1/2 5 2 5 2 7-1/2 3 3 7-1/2 10 10 5 15 5 15 7-1/2 20 7-1/2 20 25 10 30 10 25 30 40 15 15 11 40 50 20 20 60 OBSOLETE CIRCUIT BREAKERS 50 25 30 40 150 50 60 125 60 150 75 a b www.schneider-electric.us 200 Magnetic Trip Settings b MIN MAX 1000% 800% 700% 600% 400% 400% 400% 300% 700% 700% 600% 600% 500% 500% 500% 400% 400% 300% 300% 300% 700% 700% 600% 600% 500% 500% 700% 700% 600% 600% 500% 700% 600% 600% 500% 500% 500% 400% 400% 700% 700% 600% 600% 600% 500% 500% 400% 700% 700% 700% 700% 700% 700% 700% 700% 700% 3500% 2800% 2500% 2000% 1600% 1400% 1300% 1200% 2700% 2600% 2500% 2200% 2100% 1900% 1800% 1700% 1500% 1300% 1200% 1100% 2600% 2400% 2300% 2000% 1900% 1600% 2500% 2300% 2100% 2000% 1700% 2600% 2300% 2100% 2100% 1800% 1800% 1700% 1500% 2700% 2600% 2300% 2100% 2000% 1800% 1700% 1600% 1400% 1400% 1400% 1300% 1500% 1400% 1400% 1400% 1300% Motor full-load currents are taken from NEC Table 430.150. Select wire and circuit breakers on basis of horsepower rather than nameplate full-load current per NEC 430.6 (A) for general motor applications. Do not use these values to select overload relay thermal units. See Digest Section 15 for selection of thermal units when actual full load current is not known. The voltages listed are rated motor voltages. Corresponding nominal system voltages are 200 to 208, 220 to 240, 440 to 480 and 550 to 600 volts. Only MIN and MAX settings are shown, intermediate settings are available on all circuit breakers. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-28 OptionalLugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-23 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-5 11-10 DE2 Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers UL Listed Marine Circuit Breakers Class 600 www.schneider-electric.us These marine circuit breakers are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. A standard for molded case circuit breakers which are intended to be installed and used aboard a boat or vessel is included in Supplement SA to UL 489, “Standard for Molded Case Circuit Breakers and Circuit Breaker Enclosures’’ (also referred to as UL product category DKTY). This UL Standard was established in accordance with U.S. Coast Guard regulations, applicable American Boat and Yacht Council Inc. publications, and NFPA® 302 “Standard for Motor Craft (Pleasure and Commercial)’’. In order to be UL Listed for marine use, circuit breakers must not use aluminum or aluminum alloys for terminal connections and must be calibrated at an ambient temperature of 40 oC. Standard circuit breakers should not be specified or used in place of marine circuit breakers. The following table lists those circuit breakers which are UL Marine Listed for use on vessels over 65 ft. (19.8 m) in length. (PowerPact H and J-frame circuit breakers can also be used in vessels under 65 ft. [19.8 m] in length.) Table 11.19: Cat. No. Prefix Poles Ampere Rating Application Cat. No. $ Price 2, 3 2, 3 2, 3 2, 3 15–100 A 70–250 A 70–250 A 110–250 A For use only on vessels over 65 feet (19.8 m) in length. Add the number “9’’ after the catalog number prefix of the standard circuit breaker catalog number. Example: Standard FAL36100 Marine FAL936100 There is a 20% adder to the price of the equivalent standard circuit breaker. All marine circuit breakers are supplied with copper lugs. 11 OBSOLETE CIRCUIT BREAKERS FC, FCL KA, KAL KH, KHL KC, KCL CIrcuit Breakers for Marine Applications © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule 11-11 Obsolescent Circuit Breakers Circuit Breakers for NQO, NQOB and NQOD Panelboards, Branch Circuit Breakers and Mounting Assemblies for ML Panelboards www.schneider-electric.us NQO, NQOB, and NQOD circuit breakers and panelboards are obsolete. Do not use on new applications. Limited service stock is available for replacement or fill purposes. Contact your local Sales Office for product availability. Replacing Obsolescent Q1 and Q1B Circuit Breakers In NQO, NQOB and NQOD Panelboards 2P QO Q1 and Q1B circuit breakers have been replaced by QO and QOB circuit breakers. Table 1 below is used for replacing 1P, 2P or 3P Q1 and Q1B circuit breakers with QO and QOB branch circuit breakers in NQO, NQOB and NQOD panelboards. Table 2 below is used for replacing Q1 and Q1B main circuit breakers in NQO and NQOB panelboards. Table 11.20: Replacing Q1 and Q1B Circuit Breakers with QO and QOB Branch Circuit Breakers Branch Circuit Breaker Panelboard Type Obsolete Available Mounting Assembly Requiredc Q1B QOB QO QOB SK5668 SKNQOD225b SKNQOD225b NQOB NQOD NQOD 2P QOB Table 11.21: a b c Replacing Q1 and Q1B Main Circuit Breakers in NQO and NQOB Panelboards Main Circuit Breaker Panelboard Type Obsolete Available Mounting Assembly Requiredc Retaining Kit Required NQOB Q1B QOB SK5668 — Mounting assembly SK5669 is used to mount both Q1 and QO circuit breakers. Not required for replacement purposes. 225 A maximum. For 400–600 ampere circuit breaker mounting assembly, see Class 1630 Service Bulletin. Discount Schedule PE1A. Branch Circuit Breakers and Mounting Assemblies for ML Panelboards Replacement circuit breakers for ML panelboards are determined by the manufacture date of the panel and the panel depth. (See chart below) 2P Q1 Table 11.22: Replacement Circuit Breakers in ML Panelboards Panel Depth Manufacture Date 1948–1956 1958–1961 1962–1968 in. mm 8.63 10.00 10.63 219 254 270 Availability of Replacement Circuit Breakers No Replacements Available No Replacements Available Refer to Tables Below 11 The tables below are used for replacing or adding circuit breakers to 10-5/8 inch deep ML panelboards manufactured from 1962–1968 and for switchboards manufactured from 1962–1968. OBSOLETE CIRCUIT BREAKERS Table 11.23: Ampere Rating in. mm Cat. No. Prefix Replacement Circuit Breaker Mounting Assembly Required ML-1 ML-3 LA (W) MA (W) FAL KAL LAL MAL MAL 15–100 A 100–225 A 225–400 125–1000 A 15–100 A 70–250 A 125–400 A 300–1000 A 125–250 A 4.50 6.00 8.25 8.25 4.50 4.50 6.00 9.00 9.00 114 152 210 210 114 114 152 229 229 989 or 999 997 LA MA FAL KAL LAL MAL MAL FAL KAL LAL MAL FAL KAL LAL MAL LAL SK4515d SK4516d SK4517 SK4578 Table 11.24: d 11-12 Replacement of Existing Circuit Breakers Existing Circuit Breaker Mounting Height No Mounting Assembly Required SK4517 Single or Twin Poles (Mounting Required Assembly) 3P 3P 3P 3P 3P 3P 3P 3P 3P Twin Twin Single Single Twin Twin Single Single Single Availability Not Available Adding New Circuit Breakers Mounting Height Cat. No. Prefix Ampere Rating Mounting Assembly Required in. mm Poles Required Single or Twin (Mounting Assembly) FAL KAL LAL MAL 15–100 A 70–250 A 125–400 A 300–1000 A SK4515 SK4516 SK4517 SK4578 4.50 4.50 6.00 9.00 114 114 152 229 3P 3P 3P 3P Twin Twin Single Single Mounting assemblies for twin-mounted circuit breakers will only accept the same family and configuration of circuit breakers, i.e., FAL and FAL. DE5A PE1A Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers Rating Plugs For Obsolete Electronic Trip Circuit Breakers Class 666, 671, 677 www.schneider-electric.us These rating plugs are for electronic circuit breakers which are obsolete. Please refer to Digest 176 for PowerPact™ circuit breakers for new installations or replacement. Replacement rating plugs for circuit breakers manufactured before Micrologic™. Replacement Rating Plugs for PreMicrologic Circuit Breakers Circuit Breakers Manufactured Before Micrologic Frame Size 225 A ME Circuit Breakers Manufactured before Micrologic ME 400 A 800 A 1200 A PE Micrologic Circuit Breakers PE-G/PEC-G Built before June 1, 1982 and all PE/PEC 1600 A 2000 A 1200 A PE Circuit Breakers Manufactured before Micrologic PE-G/PEC-G Built after June 1, 1982 1600 A 2000 A Table 11.26: SE Micrologic Circuit Breakers © 2012 Schneider Electric All Rights Reserved Circuit Breaker Ampere Rating Cat. No. 100 A 110 A 125 A 150 A 175 A 250 A 350 A 450 A 500 A 700 A 600 A 700 A 800 A 900 A 1200 A 1000 A 1200 A 1400 A 1000 A 1200 A 1400 A 1800 A 2000 A 600 A 700 A 800 A 1000 A 1200 A 1000 A 1200 A 1400 A 1000 A 1200 A 1400 A 1800 A 2000 A ME2100 ME2110 ME2125 ME2150 ME2175 ME4250 ME4350 ME8450 ME8500 ME8700 PE120600 PE120700 PE120800 PE120900 PE121200 PE161000 PE161200 PE161400 PE161000 PE161200 PE161400 PE201800 PE202000 PEG120600 PEG120700 PEG120800 PEG121000 PEG121200 PEG161000 PEG161200 PEG161400 PEG161000 PEG161200 PEG161400 PEG201800 PEG202000 Interchangeable Rating Plug Kits for ME, NE, PE and SE Circuit Breakers with Full-Function Micrologic Trip System Manufactured Between December 1989 and September 1992 Old Cat. No. New Cat. No. Multiplier Value RP040 RP050 RP056 RP058 RP060 RP063 RP067 RP070 RP075 RP080 ARP040 ARP050 ARP056 ARP058 ARP060 ARP063 ARP067 ARP070 ARP075 ARP080 0.400 0.500 0.563 0.583 0.600 0.625 0.667 0.700 0.750 0.800 RP083 RP088 RP090 RP100 ARP083 ARP088 ARP090 ARP100 0.833 0.875 0.900 1.000 DE5A Table 11.27: DE2 Discount Schedule Replacement Rating Plugs for Micrologic Circuit Breakers Frame Size 225 A Micrologic ME Series 3 400 A 800 A Micrologic NE Series 1 1200 A 1200 A Micrologic PE Series 4 1600 A 2000 A 200 A 400 A Micrologic SE Series 2 800 A 1200 A 1600 A 2000 A e Ampere Rating Cat. No.e 100 A 110 A 150 A 175 A 250 A 450 A 500 A 700 A 600 A 630 A 700 A 800 A 900 A 1000 A 600 A 700 A 1000 A 1200 A 1000 A 1200 A 1000 A 1200 A 1400 A 1600 A 1800 A 100 A 125 A 150 A 175 A 200 A 200 A 250 A 300A 350 A 450 A 500 A 700 A 800 A 1000 A 1200 A 1600 A 2000 A ME2100RP ME2110RP ME2150RP ME2175RP ME4250RP ME8450RP ME8500RP ME8700RP NE120600RP NE120630RP NE120700RP NE120800RP NE120900RP NE121000RP PE120600RP PE120700RP PE121000RP PE121200RP PE161000RP PE161200RP PE201000RP PE201200RP PE201400RP PE201600RP PE201800RP S9020100RP S9020125RP S9020150RP S9020175RP S9020200RP S9040200RP S9040250RP S9040300RP S9040350RP S9080450RP S9080500RP S9080700RP S9120800RP S9121000RP S9121200RP S9161600RP S9202000RP Contact your nearest local sales office for availability. OBSOLETE CIRCUIT BREAKERS Table 11.25: 11 ME Micrologic Circuit Breakers 11-13 Obsolescent Circuit Breakers EH/EHB Circuit Breakers Class 590, 652 www.schneider-electric.us EH/EHB circuit breakers are obsolete. Do not use on new applications. Limited service stock is available for replacement or fill purposes. Contact your local Sales Office for product availability. Table 11.28: E Frame—100 A, Thermal Magnetic (480Y/277 Vac) 1P 277 Vac—14 kA 120 Vac—65 kA Amp Rating Plug-On Cat. No. 2P 480Y/277 Vac—14 kA 120/240 Vac—65 kA 3P 480Y/277 Vac—14 kA 240 Vac—65 kA Bolt-On Bolt-On Bolt-On Availability Cat. No. Availability Cat. No. Requires 1 Space Requires 1 Space Availability Cat. No. Availability Wire Size (AWG) Al Cu Wire Temp. Requires 3 Spaces Requires 2 Spaces EH/EHB Circuit Breakers 15 A 20 A 25 A 30 A 35 A 40 A 45 A 11 50 A OBSOLETE CIRCUIT BREAKERS 60 A 70 A 80 A 90 A 100 A 100 A Not Available — — Not Available Not Available — — Not Available EHB14015 a — EHB140151082 EHB14020 a — — — Not Available — — — Not Available — Not Available — Not Available Not Available — — — Not Available Not Available — — Not Available Not Available — — — Not Available — — — — — — — Not Available — — — Not Available Not Available — — Not Available Not Available — — — Not Available — — — — — — — Not Available EHB140301082 — — Not Available Not Available — — Not Available Not Available — — — Not Available — — — — — — — EHB24015 — — Not Available — — Not Available EHB34015 EHB340151042 EHB340151082 EHB34020 — — — — (2) 14–10 (2) 14–10 (2) 14–10 (2) 14–10 60/75 oC 60/75 oC 60/75 oC 60/75 oC — Not Available — Not Available — Not Available Not Available Not Available — Not Available Not Available Not Available EHB340201042 EHB340201082 EHB340201212 Not Available — — — 12–8 (2) 14–10 (2) 14–10 (2) 14–10 14–8 60/75 oC 60/75 oC 60/75 oC 60/75 oC Not Available Not Available EHB240301042 EHB240301082 — Not Available Not Available — — Not Available EHB24050 — — — EHB24060 — — Not Available Not Available Not Available EHB24100b EHB241001082 Not Available EHB34030 EHB340301082 EHB340301212 EHB3403035 EHB34035 Not Available Not Available EHB340401212 Not Available Not Available EHB340501042 EHB340501082 Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available 12–8 12–8 12–8 12–8 12–2 12–2 12–2 12–2 12–2 12–2 12–2 12–2 12–2 12–2 12–2 12–2 4–2/0 4–2/0 4–2/0 4–2/0 4–2/0 14–8 14–8 14–8 14–8 14–2 14–2 14–2 14–2 14–2 14–2 14–2 14–2 14–2 14–2 14–2 14–2 4–2/0 4–2/0 4–2/0 4–2/0 4–2/0 60/75 oC 60/75 oC 60/75 oC 60/75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC 75 oC Not Available — (2) 14–10 Not Available — 12–8 12–8 (2) 14–10 14–8 14–8 60/75 oC 60/75 oC 60/75 oC 60/75 oC — — — Not Available Not Available — — Not Available Not Available — — — Not Available — — — — — — — — Not Available Not Available — — Not Available — — — — — Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available EH/EHB HID Circuit Breakers — For Use on High Intensity Discharge Lighting Systems 15 A Not Available Not Available Not Available 20 A 25 A 30 A Not Available Not Available Not Available Not Available Not Available Not Available EHB14020HIDa Not Available Not Available a b 11-14 Not Available EHB24015HID Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available EHB34020HID Not Available EHB34030HID UL Listed as SWD (switching duty) rated. For use only in Series 3 or Series E1 panelboards. Contact your nearest local sales office for use in earlier series panelboards DE5A Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers FJA Thermal-Magnetic Circuit Breakers www.schneider-electric.us FJ 3-pole circuit breakers are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. Table 11.29: Mechanical Lug Kit Information Circuit Breaker Application Standard Ampere Rating Optional Ampere Rating Number of Wires Per Lug and Wire Range Kit Cat. No. Lugs Per Kit AL100FD 3 Al Lugs for Use with Al or Cu Wire FJ 35–125 A Table 11.30: FJ 15–30 A (1) 12–2/0 AWG Al or (1) 14–2/0 AWG Cu Handle Accessories Circuit Breaker Type No. of Poles Cat. No. HPAFD 11 OBSOLETE CIRCUIT BREAKERS Handle Padlock Attachment (locks ON or OFF) FJ 1, 2 or 3 © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule 11-15 Obsolescent Circuit Breakers QE Metering Circuit Breakers www.schneider-electric.us QE circuit breakers are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. Table 11.31: Table 11.31: Branch Circuit Breakers Branch Device Branch Device System Type Branch Circuit Breaker Ampere Rating Cat. No. System Type 200 A Max. QE270VH QE280VH QE290VH QE2100VH QE2125VH QE2150VH QE2175VH QE2200VH Branch Circuit Breaker Availability Ampere Rating Cat. No. Availability Not Available 70 A 80 A 90 A 100 A 125 A 150 A 175 A 200 A QE370VH QE380VH QE390VH QE3100VH QE3125VH QE3150VH QE3175VH QE3200VH Not Available Not Available Not Available Not Available Not Available Not Available Not Available 1Ø IN – 1Ø OUT or 3Ø IN – 1Ø3W OUT 70 A 80 A 90 A 100 A 125 A 150 A 175 A 200 A Branch Circuit Breakers 200 A Max. Not Available Not Available 3Ø IN 3Ø OUT 11 OBSOLETE CIRCUIT BREAKERS 11-16 DE5A Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers KD/KG Thermal-Magnetic Circuit Breakers Class 540 www.schneider-electric.us KD and KG circuit breakers are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. Table 11.32: KDL and KGL Circuit Breaker 3P 100–250 A PowerPact™ K Frame—250 A, Thermal-Magnetic (240 Vac) Continuous Current Rating @ 40o C AC Magnetic Trip Settings D Interrupting Level G Interrupting Level Terminal Wire Range Hold Trip Cat. No. Availability Cat. No. Availability 1100 A 1100 A 1100 A 1100 A 1400 A 1400 A 1400 A 1400 A 1700 A 1700 A 1700 A 1700 A 2400 A 2400 A 2400 A 2400 A KDL22100 KDL22110 KDL22125 KDL22150 KDL22175 KDL22200 KDL22225 KDL22250 Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available KGL22100 KGL22110 KGL22125 KGL22150 KGL22175 KGL22200 KGL22225 KGL22250 Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available AL250KD 6 AWG–350 kcmil Al or Cu 1100 A 1100 A 1100 A 1100 A 1400 A 1400 A 1400 A 1400 A 1700 A 1700 A 1700 A 1700 A 2400 A 2400 A 2400 A 2400 A KDL32100 KDL32110 KDL32125 KDL32150 KDL32175 KDL32200 KDL32225 KDL32250 KGL32100 KGL32110 KGL32125 KGL32150 KGL32175 KGL32200 KGL32225 KGL32250 Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available AL250KD 6 AWG–350 kcmil Al or Cu 2P, 240 Vac 100 A 110 A 125 A 150 A 175 A 200 A 225 A 250 A 3P, 240 Vac 100 A 110 A 125 A 150 A 175 A 200 A 225 A 250 A Table 11.33: Kit Catalog Number Not Available Not Available Not Available Not Available Mechanical Lug Kit Information Circuit Breaker Application Standard Ampere Rating Number of Wires Per Lug and Wire Range Torque Lugs Per Kit Availability — (1) 6 AWG–350 kcmil 300 lb-in (34 N•m) 3 Not Available 100–250 (1) 6 AWG–350 kcmil 300 lb-in (34 N•m) 3 Optional Ampere Rating — KDL, KGL Al Lugs for Use with Al or Cu Wire AL250KD KDL, KGL 100–250 A Cu Lugs for Use with Cu Wire Only CU250KD Table 11.34: — — Handle Accessories Circuit Breaker Type Cat. No. Availability Handle Padlock Attachment (locks ON or OFF) HPAKD Not Available OBSOLETE CIRCUIT BREAKERS KDL, KGL Table 11.35: Interrupting Ratings (kA) KDL 25 11 240 V © 2012 Schneider Electric All Rights Reserved DE5A Discount Schedule 11-17 Obsolescent Circuit Breakers NHL Thermal-Magnetic Molded Case Circuit Breaker Class 670 www.schneider-electric.us NHL circuit breakers and related accessory products are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. NHL Circuit Breaker 800–1200 A Table 11.36: Ampere Rating 800 A 1000 A 1200 A 1200 A 800 A 1000 A 1000 A 1200 A 1200 A Table 11.37: 2P 3P Standard Lug Kit Wire Range Low High Cat. No. Cat. No. 4000 A 5000 A 5000 A 5000 A 4000 A 5000 A 5000 A 5000 A 5000 A 8000 A 10000 A 10000 A 10000 A 8000 A 10000 A 10000 A 10000 A 10000 A — — — — — NHL261000 — NHL261200 — NHF368001021 NHF3610001021 NHF361200 NHF3612001021 NHL36800 NHL361000 NHL3610001021 NHL361200 NHL3612001021 AL1200NA (4) 350–750-kcmil Mechanical Lug Kit Kit Cat. No. Circuit Breaker Ampere Rating Number of Wires Per Lug and Wire Rangea Lugs Per Kit AL1200NA NH 600–1200 (4) 350–750 kcmil 1 Table 11.38: a 11 b Compression Lug Kit Kit Cat. No. Circuit Breaker Number of Lugs Per Terminal and Wire Rangea Lugs Per Kit VC1200NA5 NH (1) 2/0 AWG–500 kcmil 1 VC1200NA7 NH (1) 500–750 kcmil Al or 500 kcmil Cu 1 Unless otherwise specified, wire sizes apply to both aluminum and copper conductors. Table 11.39: Mechanical Accessories Cat. No. Circuit Breaker HPANAb NAHEX NH NH Description Handle Padlock Attachment Handle Extension No. of Poles 2, 3 2, 3 Use with NAHEX handle extension. OBSOLETE CIRCUIT BREAKERS Table 11.40: 11-18 NHL Circuit Breaker (1200 A, 480 Vac) AC Magnetic Trip Settings Amperes Control Wire Terminations Cat. No. Standard Package Quantity AL1200NAT 1 DE5A Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers SE Circuit Breaker with Full-Function Trip Unit Class 678 www.schneider-electric.us SE circuit breakers and related accessories are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. Table 11.41: SE Circuit Breaker Fixed-Mounted Circuit Breaker Sensor Size Ampere Rating Rating Plug Installed Drawout Circuit Breaker Cat. No.ab Cat. No.ab Long-Time Short-Time Instantaneous Long-Time Short-Time Instantaneous w/Ground Faultc Long-Time Short-Time Instantaneous Long-Time Short-Time Instantaneous w/Ground Faultc SEF361200LSMR SEF363000LS — SEF363000LSMR — SEF364000LSZ SEF364000LSMRZ — — — — SEF363000LSG — SEF363000LSGMR — — SEF364000LSGMRZ SEF364000LSAMRZ — SED363000LS — SED363000LSMR — — — — SED363000LSG — SED363000LSGMR — — — SED364000LSGMR — Standard Interrupting Rating 1200 A 1200 A 3000 A 3000 A ARP100 4000 A 4000 A High Interrupting Rating 11 OBSOLETE CIRCUIT BREAKERS 1200 A 1200 A — SEHF361200LSGMR — — ARP100 3000 A 3000 A SEHF363000LSMR — — — a “MR” (Motor Ready) indicates 120 Vac spring charging motor only already installed. Does not include shunt close or shunt trip option. b “Z” indicates circuit breaker supplied without terminal connector kit. c Substitute (A) in place of (G) for ground-fault alarm (pick-up indication only). © 2012 Schneider Electric All Rights Reserved DE5A Discount Schedule 11-19 Obsolescent Circuit Breakers SE Circuit Breaker Accessories Class 678 www.schneider-electric.us SE circuit breakers and related accessories are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. Table 11.42: Field-Replaceable Electronic Trip Unit Kits (Replaceable by Field Services Only)a Trip Unit Function Cat. No. Long-Time Short-Time Instantaneous with Ground Fault Long-Time Short-Time Instantaneous Ampere Rating 400 A — 800 A SETU800LSB 800 A — 1200 A SETU1200LSB 1200 A — 1600 A — 2500 A — 3000 A SETU3000LSB 3000 A — 4000 A SETU4000LSB 4000 A — a Used only with SE circuit breaker Series 3B. Table 11.43: Long-Time Short-Time Instantaneous with Ground Fault Alarm SETU400LSGB — — — SETU800LSGB — — — SETU1200LSGB — SETU1600LSGB SETU1600LSAB SETU2500LSGB — — — SETU3000LSGB SETU3000LSAB — — SETU4000LSGB — c Fixed-mounted circuit breakers only. Does not include key interlock. SE Drawout Cell Keying Kit Table 11.46: Cell Key Positions Table Cell Keying Kit Cat. No. Frame Size SECK0400 SECK0800 400 A 800 A SECK1200 SECK1600 SECK2000 SECK2500 SECK3000 1200 A 1600 A 2000 A 2500 A 3000 A Table 11.44: Drawout Carriage Cell Key Position Availability A B C D X X X X E X Not Available Not Available X X X X X X X X Kit Cat. No. Description 11 120 Vac 24 Vdc 48 Vdc 125 Vdc 120 Vac 24 Vdc 48 Vdc 125 Vdc 120 Vac 24 Vdc 48 Vdc 125 Vdc OBSOLETE CIRCUIT BREAKERS Shunt Close Replacement Kit Shunt Tripb Replacement Kit Undervoltage Tripb Replacement Kit Auxiliary Switchb Replacement Kit Sensor Where Used SE12NCT SE12NCT SE30NCT SE30NCT SE30NCT SE30NCT SE40NCT 800 1200 1600 2000 2500 3000 4000 SE, SEH SE, SEH SE, SEH SE, SEH SE, SEH SE, SEH SE, SEH X Field-Replaceable Accessory Kits Spring Charging Motor Replacement Kit Neutral Current Transformers Cat. No. S3MOT120AC2 — — S3MOT125DC2 S3SC120AC2 S3SC024DC2 S3SC048DC2 S3SC125DC2 S3ST120AC2 S3ST024DC2 S3ST048DC2 S3ST125DC2 120 Vac — 4 ac/dc 4 ac/dc add on 4 ac only 8 ac only S34DCB2 S34DCT2 S34AC2 S38AC2 Electric Joint Compound SE drawout circuit breakers are supplied with factoryapplied joint compound on the plug-on connectors. The compound should not be removed because it contributes to the overall performance of the connection. Whenever one of these units is removed and reinstalled, the joint compound should be reapplied. PJC 8311 is a two-ounce container of compound specially formulated for the SE drawout connections. This compound MUST BE USED ON SE DRAWOUT CONNECTIONS. No other type of commercially available joint compound should be used. Table 11.47: Electric Joint Compound Used With SED Drawout Circuit Breakers Cat. No. PJC8311 Alarm Switchb 2 ac only S3AS2 Replacement Kit b Also field-installable on Series 3 and newer, and for Series 2 ground fault circuit breakers. Table 11.45: Field-Installable External Accessory Kits Kit Cat. No. Description Padlock Attachment Close Button Cover Key Interlock Bracketc Series 1 Primary Injection Test Plug Series 2 Primary Injection Test Plug SE Drawout Crank Fan Monitoring Switch Kit 11-20 SE2PA SE1CBC SE1KI SEPITK1 SEPITK2 SEDC SE40FAN DE5A Discount Schedule © 2012 Schneider Electric All Rights Reserved Molded Case Circuit Breakers M-Frame Thermal-Magnetic Circuit Breakers www.schneider-electric.us M-frame thermal-magnetic circuit breakers are obsolete. Please refer to Digest 176 for PowerPact™ molded case circuit breakers for new installations or replacement. . Table 11.48: MAL/MHL 2P and 3p 300–1000 A Ampere Rating M-Frame—Thermal-Magnetic, Individually-Mounted Circuit Breakers, 600 Vac AC Magnetic Trip Settingsa Low Standard Interrupting High Interrupting High Cat. No. Availability Cat. No. Availability Not Available Not Available Not Available Not Available Terminal Wire Range 2P, 600 Vac, 250 Vdc 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 900 A 1000 A 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A 4500 A 5000 A 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A 9000 A 10000 A MAL26300 MAL26350 MAL26400 MAL26450 MAL26500 MAL26600 MAL26700 MAL26800 MAL26900 MAL261000 Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available MHL26300 MHL26350 MHL26400 MHL26450 MHL26500 MHL26600 MHL26700 MHL26800 MHL26900 MHL261000 1200 A 5000 A 10000 A MAL261200 Not Available MHL261200 Not Available AL900MA (3) 3/0 AWG–500 kcmil Not Available Not Available Not Available Not Available AL1000MAb (4) 1/0 AWG–350 kcmil 3P, 600 Vac, 250 Vdc 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 900 A 1000 A 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A 4500 A 5000 A 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A 9000 A 10000 A MAL36300 MAL36350 MAL36400 MAL36450 MAL36500 MAL36600 MAL36700 MAL36800 MAL36900 MAL361000 Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available MHL36300 MHL36350 MHL36400 MHL36450 MHL36500 MHL36600 MHL36700 MHL36800 MHL36900 MHL361000 1200 A 5000 A 10000 A MAL361200 Not Available MHL361200 a b Not Available Not Available Not Available AL900MA (3) 3/0 AWG–500 kcmil Not Available AL1000MAb (4) 1/0 AWG–350 kcmil UL magnetic trip setting tolerances are ±25% for low and ±20% for high from nominal values shown. The AL100MA lug is the only lug available for the 1200 A MA and MH circuit breakers. Table 11.49: Ampere Rating M-Frame—Thermal-Magnetic, I-Line™ Construction Circuit Breakers, 600 Vac AC Magnetic Trip Settingsc Low Standard Interrupting High Cat. No. 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A MA26300( ) MA26350( ) MA26400( ) MA26450( ) MA26500( ) MA26600( ) MA26700( ) MA26800( ) 3000 A 3500 A 4000 A 4500 A 5000 A 6000 A 7000 A 8000 A MA36300 MA36350 MA36400 MA36450 MA36500 MA36600 MA36700 MA36800 Availability High Interrupting Cat. No. Availability Terminal Wire Range 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available MH26300( ) MH26350( ) MH26400( ) MH26450( ) MH26500( ) MH26600( ) MH26700( ) MH26800( ) Not Available Not Available Not Available Not Available Not Available Not Available Not Available Not Available AL900MA (3) 3/0 AWG–500 kcmil 3P, 600 Vac, 250 Vdc 300 A 350 A 400 A 450 A 500 A 600 A 700 A 800 A Not Available Not Available Not Available Not Available Not Available MH36300 MH36350 MH36400 MH36450 MH36500 MH36600 MH36700 MH36800 Not Available Not Available Not Available AL900MA (3) 3/0 AWG–500 kcmil Not Available Not Available UL magnetic trip setting tolerances are ±25% for low and ±20% for high from nominal values shown. 2P circuit breaker catalog numbers are completed by adding required phase connection letters as suffix to catalog numbers. See Phase Options table. Table 11.50: Voltage 240 Vac 480 Vac 600 Vac Interrupting Ratings MA/MAL 42 kA 30 kA 22 kA MH/MHL 65 kA 65 kA 25 kA 11 c d 1500 A 1750 A 2000 A 2250 A 2500 A 3000 A 3500 A 4000 A Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-28 OptionalLugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-23 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-5 Enclosures: see Digest Section 7 © 2012 Schneider Electric All Rights Reserved DE2 Discount Schedule OBSOLETE CIRCUIT BREAKERS 2P, 600 Vac, 250 Vdcd 11-21 Circuit Breaker Accessories Field-Installable Accessories www.schneider-electric.us Field-Installable Electrical Accessories Complete field-installable accessory catalog number by inserting suffix from Digest page 736 between the parentheses in the catalog numbers shown in the table below. (Example: LA11212) See Digest page 7-36 for accessory pricing; add 20% to factory-install fieldinstallable devices. Auxiliary Switch Contact Configuration Color Code: "A" Contact - Yellow Leads "B" Contact - Blue Leads Common-Striped Leads Table 11.51: Field-Installable Accessories for Thermal-Magnetic and Electronic Trip Circuit Breakers 1A/1B A Circuit Breaker B Ground-Fault Shunt Tripa Undervoltage Trip Auxiliary Switches MA1( ) MA1G MA1 ( ) MA1( ) ME, MX Factory-Installed Only Factory-Installed Only Factory-Installed Only Factory-Installed Only Circuit Breaker Closed A Shunt Trip MA, MH Series 2 NA, NC, NE, NX NA1( ) NA1( ) NA1( ) NA1( ) Series 1, 2, 3 PA, PH, PC Factory-Installed PA1( ) PA11121 PA1( ) Series 4 Only PE, PX Factory-Installed PA11121 PA1( ) PA1( ) Series 4, 5, 6 Only a Used with obsolete GP Ground-Censor™ system or add-on ground-fault modules. B Circuit Breaker Open or Tripped 1A Alarm Switch Configuration 1B Alarm Switch Configuration Color Code: Red Leads Color Code: Red Leads Circuit Breaker Open or Closed Circuit Breaker Tripped Circuit Breaker Tripped Circuit Breaker Open or Closed Table 11.52: Alarm Switch Factory-Installed Only Center Pole Factory-Installed Only NA1( ) Factory-Installed Only Factory-Installed Only Accessory Mounting Locations MA, MH Series 2 circuit breakers or newer = Fieldinstallable accessories ME/MX circuit breakers = Not field-installable accessories L R Undervoltage Trip Wiring Diagram Brown Brown Wires To Be Connected To Control Power UVR Brown R2 11 Shunt Trip Wiring Diagram NA, NC, NE, NX circuit breakers - FIeld-installable accessories “L” port and “R” port will accept shunt trips, alarm switches and UVRs; “R2” port will accept auxiliary switches. Maximum of one device per port. OBSOLETE CIRCUIT BREAKERS Black L Black Wires To Be Connected To Control Power Shunt Trip R1 Black 11-22 PA, PH, PC, PE, PX Series 4 circuit breakers or newer = FIield-installable accessories. L1 R1 L2 R2 “L1” a nd “L2” or “R1” and “R2” port combinations are required to mount a single shunt trip. Both “L2” and “R2” ports will accept a UVR. Both “L1” and R1” ports will accept auxiliary switches. If alarm switch is factory installed in PA or PC circuit breaker, it will be installed in “R2” port. For a PE or PX circuit breaker, the alarm switch will be factory installed in “L2” port. © 2012 Schneider Electric All Rights Reserved Circuit Breaker Accessories Mechanical Lug Information www.schneider-electric.us AL900MA Table 11.53: Mechanical Lug Kit Information Circuit Breaker Application Standard AL800MA7 AL1000MA Ampere Rating Optional Ampere Rating Cat. No. Lugs Per Kit Availability Per Kit AL600LI7 AL900MA AL800MA7 AL1000MA AL250ME AL400ME7 AL800MA7 AL900MA AL1000MA AL1200NE6 1 1 1 1 3 1 1 1 1 1 Not Available Not Available AL2500PA 2 CU1000MA CU250ME CU1000MA CU1200NE6 1 3 1 1 (Number of Wires Per Lug ) Wire Rangea Al Lugs for Use with Al or Cu Wire — — LC, LI, LE, LX, LXI — (1) 500–750 kcmil MA, MH 300–1000 A — — (3) 3/0 AWG–500 kcmil — — MA, MH 300–1000 A (2) 500–750 kcmil — — MA, MH 300–1200 A (4) 1/0 AWG–350 kcmil ME, MX 100–250 A — — (1) 6 AWG–350 kcmil — — ME, MX 250–400 A (1) 350–750 kcmil — — ME, MX 100–800 A (2) 500–750 kcmil ME, MX 300–800 A ME, MX 100–250 A (3) 3/0 AWG–500 kcmil — — ME, MX 300–1200 A (4) 1/0 AWG–350 kcmil NA, NC, NE, NX 600–1200 A — — (4) 3/0 AWG–600 kcmil PAF, PHF, PEF, PXF, — — 600–2500 A (1) 1/0 AWG–750 kcmil PCF Cu Lugs for Use with Cu Wire Only c — — MA, MH 300–1000 A (3) 3/0 AWG–500 kcmil Cu — — ME, MX 125–250 A (1) 4 AWG–250 kcmil Cu — — ME, MX 100–800 A (3) 3/0 AWG–500 kcmil Cu — — NA, NC, NE, NX 600–1200 A (4) 3/0 AWG–600 kcmil Cu a Unless otherwise specified, wire sizes apply to both aluminum and copper conductors. b For use in the OFF end only, when the OFF end is the load end. c Use suffix 8002 for factory-installed Cu lugs. (20% adder.) Not Available Not Available Not Available Compression Lug Kits Field-installable Compression Lug Kitsa AL2500PA Dimension A (In) Wire Rangeb Max. Lugs Per Terminal Aluminum Compression Lug Kits 2/0 AWG–500 kcmil 1.9 2 MA, MH 500–750 kcmil 2.1 2 4 AWG–300 kcmil 1.5 1 ME2, MX2 250–350 kcmil 1.5 1 2/0 AWG–500 kcmil 2.2 1 ME4, MX4 500–750 kcmil Al 2.5 1 or 500 kcmil Cu 2/0 AWG–500 kcmil 1.9 2 ME, MX, MA, MH 500–750 kcmil Al 2.1 2 or 500 kcmil Cu 2/0 AWG–500 kcmil 3.3 4 NA, NC, NE, NX 500–750 kcmil Al 3.6 4 or 500 kcmil Cu 2/0 AWG–500 kcmil c 6–8 PAF, PHF, PCF, PEF 2/0 AWG–500 kcmil c 6–8 Copper Compression Lug KitsNot Available ME4, MX4 250–500 kcmil Cu 2.6 1 ME, MX 250–500 kcmil Cu 2.4 2 250–500 kcmil Cu 3.3 4 NA, NC, NE, NX 500–750 kcmil Cu 3.6 4 a See instruction bulletins for recommended tools. b Unless otherwise specified, wire sizes apply to both aluminum and copper conductors. c All P-frame circuit breakers require terminal pads for mounting lugs of any type. Cat. No. Lug Qty. Per Kit VC600MA5 VC800MA7 VC250ME3 VC250ME35 VC400ME5 2 2 3 3 1 Availability Not Available Not Available Not Available Not Available Not Available VC400ME7 1 Not Available VC600MA5 2 Not Available VC800MA7 2 Not Available VC1200NE5 4 Not Available VC1200NE7 4 Not Available VC2000PA5 VC2500PA7 4 4 Not Available Not Available CVC400ME5 CVC600MA5 CVC1200NE5 CVC1200NE7 1 2 4 4 Not Available Not Available Not Available Not Available Power Distribution Connectors (PDC) for Circuit Breakers—for Field Replacement of Mechanical Lugs Can be used for multiple load connections on one circuit breaker. Use in place of standard distribution blocks to save space and time. Field-installable kits, including tin-plated aluminum connectors and all necessary mounting hardware are available for Square D FA, LA and Q4-frame molded case circuit breakers. Connectors are UL Listed: • • • • For use on load end of circuit breaker only For use in UL508 Industrial Control applications only For use in UL 1995/CSA C22.2 No. 236 heating and cooling equipment For copper wire only Table 11.55: PDC Lugs Use With Circuit Breakerd MAL, MHL, MEL, MXL d e f © 2012 Schneider Electric All Rights Reserved Cicuit Breaker Ampere Rating Wires Per Terminal & Wire Rangee Cu Cat. No. Lug Quantity Per Kit Dimension A (i.) 125–1000 A (6) 12–2/0 AWG Cu (12) 14–4 AWG Cu PDC6MA20 PDC12MA4 1 1 0.0 0.0 Availability Not Available Not for use with I-Line circuit breakers. When using fine stranded wire, increased cross sectional area may cause maximum wire size to be reduced. OFF end only when OFF end is the load end. DE2 Discount Schedule 11-23 OBSOLETE CIRCUIT BREAKERS Circuit Breaker Type 11 Table 11.54: Electronic Products Micrologic™ Series 2/3/A/B Trip Unit Test Sets Class 690 www.schneider-electric.us NOTE: Listed below are the catalog numbers and the components required for testing the entire family of Micrologic trip systems. The listing includes obsolete series trip systems. Micrologic Series B Trip Systems Identified by label on front of trip unit (LE/LX/LXI, ME/MX, NE/NX and PE/PX circuit breaker 9/92 to present) (SE circuit breaker 10/92 to present) This is the latest series of standard (LX/LXI, MX, NX and PX) and full-function (LE, ME, NE, PE and SE) Micrologic trip systems. Table 11.56: Universal Test Set Description Cat. No. Universal Test Set includes the following: 1. Self-test module (CBTMT) 2. Standard and full-function Micrologic Series B module (CBTMB) includes rating plug adapter 3. Power cord 4. Ribbon cable for making the connection from the test set to the rating plug adapter 5. Instruction manual UTS3 For those customers who already own the Universal Test Set and want to test the latest standard and full-function (Series B) trip systems, all that is needed is Micrologic Series B module (CBTMB). Included is the rating plug adapter and instruction manual. CBTMB Replacement ribbon cable and rating plug adapter for CBTMB CBTMBRK Long-time and ground-fault memory reset module (Series B Electronics) MTMB Micrologic Series 3 and Series A Trip Systems Identified by two rows of rotary switches (ME/MX, NE/NX and PE/PX circuit breakers 11/89 to 9/92) (SE circuit breakers 5/90 to 10/92) For those customers who already own the Universal Test Set (CBTU1 or UTS3) and want to test these earlier series Micrologic trip systems, see the following chart. Table 11.57: Micrologic Series 3 and Series A Circuit Breaker Test Module Circuit Breaker Test Module Cat. No. Includes rating plug adapter and instruction manual CBTM4A Replacement ribbon cable and rating plug adapter for CBTM4A CBTM4RK 11 Micrologic Series 2 Trip Systems OBSOLETE CIRCUIT BREAKERS Identified by only one row of rotary switches Micrologic Series 2 Test Modules are obsolete and no longer available. Table 11.58: Micrologic Series 2 Circuit Breaker Test Module Circuit Breaker Test Modules SE (5/85-5/90) includes rating plug adapter and instruction pages Replacement ribbon cable and rating plug for CBTM1 Cat. No. Availability CBTM1 Not Available CBTM1A Not Available ME, PE (4/85-11/89) CBTM2 obsolete, no longer available CBTM2 Not Available ME, NE, PE (10/86-11/89) includes rating plug adapter and instruction manual CBTM3 Not Available CBTM3A Not Available Replacement ribbon cable and rating plug for CBTM3 Table 11.59: Micrologic Series 1 Trip Systems for Circuit Breakers Manufactured Before Micrologic Trip System Test Set ME/PE (8/78-4/85) Identified by slide type switches instead of rotary switches. The very first series ME and PE electronic trip circuit breakers offered by Square D. Test Set Not Available SE (7/83-5/85) The very first series of SE electronic trip circuit breakers had rotary switches and can be identified by a three-digit serial number. Test Set Not Available Note: For trip systems of this type that require testing, contact Technical Services toll free at 1-800-634-2003. Table 11.60: Neutral Current Transformers Cat. No. Availability ME25CT2 ME4CT2 ME8CT2 Not Available Not Available Not Available NE12CT2 PE12CT2 PE16CT2 PE20CT2 PE25CT2 11-24 DE2 Not Available Not Available Not Available Not Available Discount Schedule Sensor Where Used 250 A 400 A 800 A MXL,MEL 1200 A NXL,NEL 1200 A 1600 A 2000 A 2500 A PXF, PEF © 2012 Schneider Electric All Rights Reserved Ground-Fault Protection Micrologic™ Add-On Ground-Fault Module (GFM) Class 931, 940, 960 www.schneider-electric.us • NOTE: Ground-fault modules cannot be reverse fed. Table 11.61: Output SE 2 (Ground Fault) 50 SE 2 (Short Time) ME 3, NE1, PE 4 50 ME 4, 5 & 5A, NE 2, 3 & 3A, PE 50 5, 6 & 6A, SE 3, 3A LE 1B, ME 5B, NE 3B, PE 6B, 50 SE 3B GC 100 R GFMa 50 RIM32 50 a GFM is an output device only. R R 15 R R 2 R R 13 R R 47 R 50 R 50 R 50 R R 1 1 7 R 14 R 10 1 R 26 R 44 R R 2 50 R 1 7 R 1 37 R 5 50 7 50 R 10 15 50 6 GC100 1 R RIM 32 Inputs Module/Enclosure Selection Chart Companion Enclosure Space Required Ground-Fault Circuit Pickup Cat. No. I-Line Individual Adjustment Availability Breaker Switchboard Enclosure a Prefix Range FAL, FHL, FCL, FA, GFM100FA LA KA 20–100 A FH, FC Not FI GFM100FI LA — 20–100 A Available KAL, KHL, KI, KA, GFM250 LA LA 40–200 A KH, KC a Use NEMA 1 or 3R enclosures only. See page 11-5 for dimensions. # Maximum inputs without RIM32. Self-restraint counts as one input. R RIM32(s) required to restrain any devices. Note: Note: Present design. Invalid combination. The RIM32 Restraint Interface Module is used to interface the restraint signals between various Square D Micrologic™ circuit breakers, Micrologic ground-fault modules, and GC-100 ground-fault protection systems. The restraint interface module operates on either 120 or 240 Vac, 50/60 Hz. The module is protected by a 1/4 A fuse. Allowable ZSI combinations are shown in Table 11.62. (Series numbers for current design circuit breakers end in B, for example NE Series 3B.) For double-ended or larger systems, or systems which contain devices from different columns in Table 11.62, contact your local Sales Office for combination information. If more inputs or outputs are needed, another restraint interface module is necessary. Contact your local Sales Office for information on multiple module installations. NOTE: The maximum distance between devices is 1000 ft. (305 m). Table 11.63: RIM32 11 Cat. No. RIM32 OUT GND OUT GND OUT GND No. 4 Ground Fault Restraint No. 5 Short Time Restraint Restraint No. 6 OUT GND COM GC-100 Ground Fault Restraint 240 Vac OUTPUTS CAT. NO. RIM32 PUSH TO TEST INPUTS No. 1 Ground Fault Restraint IN © 2012 Schneider Electric All Rights Reserved DE2 DE5A Discount Schedule GND No. 2 Short Time Restraint IN GND OBSOLETE CIRCUIT BREAKERS • Circuit Breaker Series LE 1B, ME 5B, NE 3B, PE 6B, SE 3B • ZSI Combinations (Where All Inputs Driven Are Same Column) ME 5A, NE 3A, PE 6A, SE 3A • ZSI Combinations ME 3, NE1, PE 4 • • • Used in combination with the FA, KA, FC, KC, FI, and KI type circuit breakers with a ground-fault shunt trip factory installed (add the suffix “G” to the circuit breaker) Adjustable ground-fault pickup levels Adjustable ground-fault time delays Integral ground fault push-to-test feature and ground-fault indicator All GFMs supplied for I-Line™ mounting, easily convertible to unit mount by removing the I-Line brackets Neutral current transformer is supplied for 3-phase 4-wire applications. Refer to instructions for proper installation Zone-selective interlocking capability is standard with upstream Micrologic trip system circuit breakers. The GFM can also be zone interlocked with the GC ground-fault system by using a restraint interface module.See Supplementary Digest 120 Vac control power is required for integral test feature. Meets NEC 230-95(c) Table 11.62: ME 4 & 5, NE 2 & 3 PE 5 & 6, SE 3 • RIM32 Restraint Interface Module SE 2 (Short Time) The Micrologic ground-fault module (GFM) is a UL Listed circuit breaker accessory for equipment protection. It is a combination ground-fault relay and ground-fault sensing device. Micrologic Add-On Ground-Fault Module Features: SE 2 (Ground Fault) GFM250 No. 3 Restraint IN GND GC-100 Ground Fault Restraint IN GND 1/4 AMPERE 120 Vac COM 11-25 Obsolescent Circuit Breakers Masterpact™ M/MP/MC Circuit Breakers, UL 489/1066 Listed www.schneider-electric.us Masterpact™ M/MP/MC circuit breakers and related accessories are obsolete. Use Masterpact NT/NW for new applications. See DIgest 176. Limited service stock is available for replacement or fill purposes. Contact your local sales office for product availability. To order a complete circuit breaker, order: 1. 2. 3. 4. 5. Circuit breaker fixed or drawout frame..........................page 11-26 or cradle only................................................................page 11-32 or circuit breaker without cradle....................................page 11-26 Connections..................................................................page 11-23 Control unit....................................................................page 11-27 Rating plug....................................................................page 11-27 Accessories...................................................................page 11-28 Fixed and Drawout breakers listed below are complete with STR58U Trip unit which includes Long time, short time, instantaneous and ground fault as well as options T (residual) and I (ammeter). Table 11.64: UL Listed Masterpact MP Circuit Breaker Frame Rating AIR/ 480 V Fixed 3P Drawout without Cradle 3P Cradle Only 3P $ Price 100 kA 100 kA 100 kA MP100135 MP100137 MP100139 MP100136 MP100138 MP100140 MP100141 MP100133 MP100132 Contact Schneider Electric Cedar Rapids Plant Customer Service Group for current pricing and availability. High Interrupting (H2) MP16 to MP30— UL 489/NEMA AB1 Standards b MP16H2 MP20H2 MP30H2 1600 A 2000 A 3000 A Not UL Listed Additional information: Catalog 0631CT9501, Data Sheet 0631HO9701 11 OBSOLETE CIRCUIT BREAKERS 11-26 DE2G Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers Masterpact™ M/MP/MC Circuit Breaker Control Units www.schneider-electric.us Masterpact™ M/MP/MC circuit breakers and related accessories are obsolete. Use Masterpact NT/NW for new applications. See DIgest 176. Limited service stock is available for replacement or fill purposes. Contact your local sales office for product availability. Table 11.65: Control Units Control Unit Ground-Fault Protectiona Without Ground-Fault Protectiona STR 58U (long-time, short-time and instantaneous protection) Table 11.66: Sensor Rating 250 A 400 A 600 A 800 A 1200 A 2500 A 5000 A Rating Plug (RL) Plug Rating Cat. No. 150 A 200 A 250 A 200 A 250 A 300 A 400 A 300 A 400 A 500 A 600 A 400 A 500 A 600 A 800 A 600 A 800 A 1200 A 1200 A 3000 A 4000 A 5000 A 54732 54733 54734 54735 54736 54737 54738 54739 54740 54741 54742 54743 54744 54745 54746 54747 54748 54750 54759 54772 54773 54774 For pricing contact your local Schneider Electric distributor. OBSOLETE CIRCUIT BREAKERS a b STR58U (long-time = 0.4x1 sensor rating) Includes Residual Type T — and Ammeter — I External neutral sensor (TCE) b– see page 11-28 M1008H2 M1008H2NG M10H2 M10H2NG M1612H2 M1612H2NG M16H2 M16H2NG M20H2 M20H2NG M25H2 M25H2NG M3230H2 M3230H2NG M32H2 M32H2NG M6340H2 M6340H2NG M6350H2 M6350H2NG M63H2 M63H2NG External neutral sensor not included. External AD module (see page 11-28) is required if load is below 20% or if setting is red zone. 11 NOTE: Mandatory for UL Listed Masterpact MP circuit breakers with STR 28D, STR 38S and STR 58U control units. Not required on IEC Rated Masterpact circuit breakers. © 2012 Schneider Electric All Rights Reserved DE2G Discount Schedule 11-27 Obsolescent Circuit Breakers Masterpact™ M/MP/MC Circuit Breaker Accessories www.schneider-electric.us Masterpact™ M/MP/MC circuit breakers and related accessories are obsolete. Use Masterpact NT/NW for new applications. See DIgest 175. Limited service stock is available for replacement or fill purposes. Contact your local sales office for product availability. Table 11.67: Neutral Sensor for 3ØH4W Systems (TCE) NOTE: External neutral transformer (TCE) must have the same rating as the circuit breaker current sensor. a Rating Cat. No. 800 A 54422 1250 A 54426 2000 A 54427 For pricing contact your local Schneider Electric distributor. Discount Schedule DE2G. Table 11.68: Accessories (Must be ordered as separate items) Accessory Description Power Supply Module (AD) Discount Schedule Cat. No. Input voltage 24/30 Vdc For STR 18M to STR 58U control units Output voltage: 24 Vdc 54440 48/60 Vdc 10 Vac 50/60 Hz 54441 DE2F 54443 220 Vac 50/60 Hz 54444 380 Vac 50/60 Hz 54446 Battery Module (BAT) Battery back-up power supply for AD module Table 11.69: DE2F 54446 Accessories for Cradle Accessory Cat. No. Position Switches 11 Four SPDT connected position switches (CE) 54590 Two SPDT disconnected position switches (CD) 54591 OBSOLETE CIRCUIT BREAKERS Door Escutcheon Can be used with fixed or drawout circuit breakers b 11-28 54594b Discount Schedule DE2F DE2F DE2G DE2 DE5A Discount Schedule © 2012 Schneider Electric All Rights Reserved Obsolescent Circuit Breakers Masterpact™ M/MP/MC Circuit Breaker Accessories www.schneider-electric.us Masterpact™ M/MP/MC circuit breakers and related accessories are obsolete. Use Masterpact NT/NW for new applications. See DIgest 175. Limited service stock is available for replacement or fill purposes. Contact your local sales office for product availability. Table 11.70: Accessories for Circuit Breaker Frame Cat. No. (XF) Cat. No. (MX) 110/127 54449 54449 220/250 54503 54503 277 a 54504 54504 24 54495 54495 48 54497 54497 100/110 a 54449 54449 200/220 a 54503 54503 250 54504a 54504 Volts (V) • Maximum 2 shunt trips or 1 shunt trip + 1 undervoltage trip. Closing Coil (XF)/Shunt Trip (MX) AC 50/60 Hz DC Undervoltage Trip (MN) AC 50/60 Hz DC 440/480 54481 24 54470 100/110 a 54474 200/220a 54478 110/127 54486 220/250 54488 100/127 54512 Time Delayed Undervoltage Trip (MNR) – Not UL Listed AC 50/60 Hz AC 50/60 Hz DC 200/240 54513 480a 54518 48/60 54511 Two Standard (2a+2b) Auxiliary Switches OBSOLETE CIRCUIT BREAKERS Spring Charging Motor (MCH)—Includes Spring Charged Switch Standard Four Auxiliary Switches (OF) Four changeovers (SPDT) 54525 One Ready to Close Switch (PF) One ready to close switch 54528 Not available on switch version 11 One Overcurrent Trip Switch (SDE) Standard “OFF” Position Lock by Key Lock Provision for KIRK key lock Ronis (1 key lock) with provision a VKA 54536 VSRA1 54533 Not UL Listed. For pricing contact your local Schneider Electric distributor. © 2012 Schneider Electric All Rights Reserved DE2G Discount Schedule 11-29 Obsolescent Circuit Breakers Masterpact™ M/MP/MC Circuit Breaker Spare Parts www.schneider-electric.us Masterpact™ M/MP/MC circuit breakers and related accessories are obsolete. Use Masterpact NT/NW for new applications. See DIgest 175. Limited service stock is available for replacement or fill purposes. Contact your local sales office for product availability. Table 11.71: Spare Parts Spare Parts Cat. No. Clusters for Cradle (Set of 2) MP25–MP30 3P MP25–MP30 4P M20–M25L 3P M20–M25L 4P M32H 3P M32H 4P M50H 3P M50H 4P MP40–MP50 3P 54063 (3) 54063 (4) 54063 (3) 54063 (4) 54063 (6) 54063 (7) Charging Handle One piece 685713 One piece 685631 Racking Handle Vertical UL 489—UL 1066 Connectors MP25–MP30 3P (set of three top or bottom connectors) 54107 (2) For pricing contact your local Schneider Electric distributor. 11 OBSOLETE CIRCUIT BREAKERS 11-30 DE2F DE2 Discount Schedule © 2012 Schneider Electric All Rights Reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Author : mra632 Create Date : 2013:11:03 12:58:19Z Modify Date : 2013:11:26 08:02:28-05:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : FrameMaker 9.0 Metadata Date : 2013:11:26 08:02:28-05:00 Producer : Acrobat Distiller 9.2.0 (Windows) Format : application/pdf Title : SD17611.book Creator : mra632 Document ID : uuid:61886c99-4557-4c86-ac6a-f68807b0549d Instance ID : uuid:f51c2a1c-c51d-49b7-ba00-c4331bcd2afb Page Mode : UseNone Page Count : 30EXIF Metadata provided by EXIF.tools