Product Detail Manual

2014-11-11

: Pdf 116620-Attachment 116620-Attachment 075352 Batch12 unilog

Open the PDF directly: View PDF PDF.
Page Count: 14

DownloadProduct Detail Manual
Open PDF In BrowserView PDF
PRODUCT SUBMITTAL / SUBSTITUTION REQUEST
TO:
PROJECT:
SPECIFIED ITEM:

Section

Page

Paragraph

Description

P R O D U C T S U B M I T TA L / S U B S T I T U T I O N R E Q U E S T E D :

Gas Actuated Fastening Systems from Powers Fasteners, Inc.

The attached submittal package includes the product description, specifications, drawings, and performance data for use in the evaluation
of the request.
S U B M I T T E D B Y:

Name:

Signature:

Company:
Address:
Date:

Telephone:

Fax:

FOR USE BY THE ARCHITECT AND/OR ENGINEER

■ Approved

■ Approved as Noted

■ Not Approved

(If not approved, please briefly explain why the product was not accepted.)

By:
Remarks:

Date:

Trak-It C3

®

Trak-It C3

PRODUCT INFORMATION

®

Gas Fastening System

PRODUCT DESCRIPTION

SECTION CONTENTS

The Trak-It C3 gas fastening system was developed for use in light-duty static
applications, including attaching drywall track to concrete, block or steel, lath to concrete
or block, furring strips to concrete or block, and plywood to concrete or block base
materials. The system is designed for speed, efficiency and consistency. Operation of a
gas fastening system does not require licensing.

GENERAL APPLICATIONS AND USES

Page No.

General Information...................... 1
Tool Specification .......................... 1
Performance Data.......................... 2
Pin Specifications .......................... 4
Ordering Information .................... 4

• Attaching steel track to concrete, block or steel
• Attaching plywood to concrete or block
• Attaching lath to concrete, block or steel
• Attaching furring strips to concrete or block

FEATURES AND BENEFITS
+ No licensing required
+ Each fuel cell contains enough gas to install up to 1,000 fasteners
+ Available for use with Stick-E™ accessories
+ Short or long track versions

Trak-It C3 Tool

APPROVALS AND LISTINGS
International Code Council, Evaluation Service (ICC-ES), ESR-2036 (Formerly ER-6157)
City of Los Angeles (COLA) Research Report LARR-25523

GUIDE SPECIFICATIONS
CSI Divisions: 03151–Concrete Anchoring, 04081-Masonry Anchorage, 05090-Metal
Fastenings, 06090-Wood and Plastic Fastenings, 09260-Finishes. Gas fastening systems
shall be Trak-It as supplied by Powers Fasteners, Inc.

TOOL SPECIFICATIONS

(Short Track)

SUITABLE BASE MATERIALS

Trak-It C3 Tool
Tool Body
Tool Length
Tool Weight
Pin Length
Pin Capacity
Power Capacity
Approximate Shots per Fuel Cell
Approximate Shots per Battery Charge

Trak-It C3-ST Tool

Precision Moulded Aluminum and Plastic
17"
8 lbs
1-1/2" total length
42 pins (22 pins - short track)
90 Joules
1,000 pins
5,500

Normal-Weight Concrete
Structural Lightweight Concrete
Concrete Masonry
Steel

c

1

www.powers.com

Canada: (905) 673-7295 or (514) 631-4216

Powers USA: (800) 524-3244 or (914) 235-6300

Trak-It C3

®

PRODUCT INFORMATION
PERFORMANCE DATA
Allowable Load Capacities for Trak-It C3 Fasteners Installed in Normal-Weight Concrete1
Shank
Diameter
in.
(mm)

Min.
Embed.
in.
(mm)

0.102
(2.59)

5/8
(15.9)
3/4
(19.1)
7/8
(22.2)
1
(25.4)

Minimum Concrete Compressive Strength (f´c )
Min.
Min.
Edge
2,000 psi (13.8 MPa) 3,000 psi (20.7 MPa) 4,000 psi (27.6 MPa) 5,000 psi (34.5 MPa)
Spacing
Distance
in.
Tension
Shear
Tension
Shear
Tension
Shear
Tension
Shear
in.
(mm)
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
(mm)
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
4
(101.6)
4
(101.6)
4
(101.6)
4
(101.6)

3
(76.2)
3
(76.2)
3
(76.2)
3
(76.2)

70
(0.31)
80
(0.36)
80
(0.36)
80
(0.36)

80
(0.36)
130
(0.58)
160
(0.71)
190
(0.85)

75
(0.33)
105
(0.47)
105
(0.47)
105
(0.47)

90
(0.40)
170
(0.76)
190
(0.85)
210
(0.93)

80
(0.36)
130
(0.58)
130
(0.58)
130
(0.58)

100
(0.44)
210
(0.93)
220
(0.98)
230
(1.02)

85
(0.38)
155
(0.69)
155
(0.69)
155
(0.69)

110
(0.49)
250
(1.11)
250
(1.11)
250
(1.11)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.

Allowable Load Capacities for Trak-It C3 Installed in Structural Lightweight Concrete1
Shank
Diameter
in.
(mm)

Min.
Embedment
in.
(mm)

Minimum
Spacing
in.
(mm)

Minimum
Edge
Distance
in.
(mm)

0.102
(2.59)

3/4
(19.1)
7/8
(22.2)
1
(25.4)

4
(101.6)
4
(101.6)
4
(101.6)

6
(152.4)
6
(152.4)
6
(152.4)

Minimum Concrete Compressive Strength (f´c )
3,000 psi (20.7 MPa) 4,000 psi (27.6 MPa) 5,000 psi (34.5 MPa)
Tension
lbs.
(kN)

Shear
lbs.
(kN)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

100
(0.44)
110
(0.49)
110
(0.49)

120
(0.53)
125
(0.56)
130
(0.58)

110
(0.49)
120
(0.53)
120
(0.53)

190
(0.85)
190
(0.85)
190
(0.85)

110
(0.49)
120
(0.53)
120
(0.53)

255
(1.13)
260
(1.16)
265
(1.18)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.

Allowable Load Capacities for Trak-It C3 Fasteners Installed Through Steel Deck into Structural
Lightweight Concrete1,2,3,4
Shank
Diameter
in.
(mm)

Min.
Embedment
in.
(mm)

Minimum
Spacing
in.
(mm)

Minimum
Edge
Distance
in.
(mm)

0.102
(2.59)

3/4
(19.1)
7/8
(22.2)

4
(101.6)
4
(101.6)

1
(25.4)
1
(25.4)

Minimum Concrete Compressive Strength (f´c )
3,000 psi (20.7 MPa)

4,000 psi (27.6 MPa)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

80
(0.36)
85
(0.38)

105
(0.47)
120
(0.53)

85
(0.38)
90
(0.40)

115
(0.51)
130
(0.58)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.
2. For fasteners installed through steel deck, the minimum edge distance is 1 inch from the edge of the deck rib and 6 inches from the end of the deck. Allowable shear loads may be applied in
any direction.
3. Fasteners are permitted to be installed in the lower or upper flute of the steel deck provided that proper installation procedures are maintained.
4. The allowable values are applicable to fasteners installed through the underside of a steel deck at the ribs and into minimum 3,000 psi structural lightweight concrete. The steel deck must have
a minimum base-metal thickness of 0.034 inch (20 gage) with a minimum yield point, Fy, of 33,000 psi and conform to the Steel Deck institute requirements for Standard Wide Rib Deck.

STRUCTUAL SAND-LIGHTWEIGHT CONCRETE
OVER STEEL DECK (MINIMUM 3,000 PSI)

c

Powers USA: (800) 524-3244 or (914) 235-6300

Canada: (905) 673-7295 or (514) 631-4216

www.powers.com

2

Trak-It C3

®

PRODUCT INFORMATION

PERFORMANCE DATA
Allowable Load Capacities for Trak-It C3 Fasteners Installed in Concrete Masonry Units1,2
Shank
Diameter
in.
(mm)

Min.
Embedment
in.
(mm)

Minimum
Spacing
in.
(mm)

Minimum
Edge
Distance
in.
(mm)

0.102
(2.59)

7/8
(22.2)
1
(25.4)

4
(101.6)
4
(101.6)

3 3/4
(95.3)
3 3/4
(95.3)

Hollow or Grouted (Any Location)
f´m ≥ 1,500 psi (10.4 MPa)
Tension
lbs.
(kN)

Shear
lbs.
(kN)

65
(0.29)
65
(0.29)

80
(0.36)
120
(0.53)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.
2. Tabulated load values are for fasteners installed in minimum 6-inch wide, Minimum Grade N, Type II lightweight, medium and normal-weight concrete masonry units conforming to ASTM C 90.
The face shell thickness of the concrete masonry units shall be a minimum of 1-1/4 inch.

Allowable Load Capacities for Trak-It C3 Fasteners Installed in ASTM A 36 Steel1,2,3
Fastener
Type
(Style)

Minimum Minimum
Spacing
Edge
Distance
in.
in.
(mm)
(mm)

1/2 inch
Steel Pin

1
(25.4)

3/16"
Tension
Shear
lbs.
lbs.
(kN)
(kN)

1/2
(12.7)

115
(0.51)

260
(1.16)

Nominal Steel Thickness
1/4"
3/8"
Tension
Shear
Tension
Shear
lbs.
lbs.
lbs.
lbs.
(kN)
(kN)
(kN)
(kN)
165
(0.73)

260
(1.16)

175
(0.78)

255
(1.13)

1/2"
Tension
Shear
lbs.
lbs.
(kN)
(kN)
175
(0.78)

205
(0.91)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.
2. Steel members must have a minimum yield strength, fy, of 36,000 psi
3. Fasteners installed in 1/2-inch-thick steel must have a minimum embedment depth of 3/8-inch.

Allowable Load Capacities for Trak-It C3 Fasteners Installed in ASTM A 572 Steel1,2,3
Fastener
Type
(Style)

Minimum Minimum
Spacing
Edge
Distance
in.
in.
(mm)
(mm)

1/2 inch
Steel Pin

1
(25.4)

3/16"
Tension
Shear
lbs.
lbs.
(kN)
(kN)

1/2
(12.7)

145
(0.64)

290
(1.29)

Nominal Steel Thickness
1/4"
3/8"
Tension
Shear
Tension
Shear
lbs.
lbs.
lbs.
lbs.
(kN)
(kN)
(kN)
(kN)
175
(0.78)

290
(1.29)

215
(0.96)

270
(1.20)

1/2"
Tension
Shear
lbs.
lbs.
(kN)
(kN)
165
(0.73)

250
(1.11)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.
2. Steel members must have a minimum yield strength, fy, of 50,000 psi
3. Fasteners installed in 1/2-inch-thick steel must have a minimum embedment depth of 3/8-inch.

Allowable Load Capacities for Trak-It C3 Plywood Pin Installed Through Plywood into Steel Track1
Fastener
Type
(Style)

Shank Diameter
in.
(mm)

16 Gage Steel Track
Tension
lbs.
(kN)

18 Gage Steel Track
Tension
lbs.
(kN)

Plywood to Steel Pin

0.102
(2.59)

65
(0.29)

40
(0.18)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.

Allowable Negative Transverse Loads Using Plywood/Densglass® Pin and Denz-TightTM Washer Fasteners1
Fastener
Type
(style)
Plywood/Densglass®
0.102” Diameter

Sheathing

Minimum
Steel Stud
Thickness
(gage)

Minimum
Stud Spacing
(inches)

Fastener Spacing
(inches)

Allowable
Negative Pressure
(psf)

Densglass® Gold

16

24

6-1/2

50

1. Allowable load capacities are based on a minimum safety factor of 3.0.
Densglass® is a registered trademark of Georgia Pacific
c

3

www.powers.com

Canada: (905) 673-7295 or (514) 631-4216

Powers USA: (800) 524-3244 or (914) 235-6300

PRODUCT INFORMATION

Trak-It C3

®

ORDERING INFORMATION

C3 Tools and Accessories
Trak-It C3 Tools
Cat No.
55011
55002

Discription

STD Box

STD Ctn.

1
1

1
1

STD Box

STD Ctn.

20

80

C3 Trak-It
C3-ST Trak-It

Tool comes with case, charger and two batteries.

Trak-It Fuel Cell
Discription

Cat No.
55010

C3 Trak-It Fuel Cell

Fuel cell works in temperatures down to 10°F.

Trak-It Pole Tools
Cat No.

Discription

STD Box

STD Ctn.

55048
55051
55053
55055

6’ Pole Tool & One Trak-It C3-ST (Short Track) Tool
8’ Pole Tool & One Trak-It C3-ST (Short Track) Tool
6’ Pole Tool
8’ Pole Tool

1
1
1
1

1
1
1
1

1/2" Steel Pin (Step Shank with Rolled Point)
Cat. No. Description
55020 1/2" Steel Pin

Shank Diameter
0.120/0.102"

Standard Box
1,000

Standard Carton
5,000

Designed for use in A36 and A572 steel beams, purlins, and bar joist. All pins are zinc plated for minimum level of corrosion resistance (mild service
condition).
Each box of pins come packaged with one fuel cell.

Standard Pins (Smooth Shank with Rolled Point)
Cat. No.
55022B
55024
55026
55028

Description
3/4" Black
1" Zinc
1 1/4" Zinc
1 1/2" Zinc

Shank Diameter
0.102"
0.102"
0.102"
0.102"

Standard Box
1,000
1,000
1,000
1,000

Standard Carton
5,000
5,000
5,000
5,000

Designed for use in concrete and masonry. All pins are zinc plated or coated with black oxide for a minimum level of corrosion resistance (mild
service condition). Each box of pins come packaged with one fuel cell.

Standard Pins with Break-free Collation (Smooth Shank with Rolled Point)
Cat. No.
55032
55033
55034
55035

Description
3/4" Black
1" Zinc
1 1/4" Zinc
1 1/2" Zinc

Shank Diameter
0.102"
0.102"
0.102"
0.102"

Standard Box
1,000
1,000
1,000
1,000

Standard Carton
5,000
5,000
5,000
5,000

Designed for use in concrete and masonry. All pins are zinc plated or coated with black oxide for a minimum level of corrosion resistance (mild
service condition). Plastic collation breaks completely free of pin during installation.
Each box of pins come packaged with one fuel cell.

Plywood/Densglass® to Steel Pin (Spiral Knurl Shank with Rolled Point)
Cat. No. Description
55036 1 3/8" Zinc

Shank Diameter
0.102"

Standard Box
1,000

Standard Carton
5,000

Designed for use to attach plywood to light gage steel framing. All pins are zinc plated for a minimum level of corrosion resistance (mild service
condition). Each box of pins come packaged with one fuel cell.

Stick-E Pins (Step Shank)
Cat. No.
55080
55081
55087
55085

Description
780 Step Shank Pin
1” Step Shank Pin
730 Step Shank Pin
680 Step Shank Pin

Shank Diameter
0.120/0.102"
0.120/0.088"
0.120/0.102"
0.120/0.102"

Standard Box
1,000
1,000
1,000
1,000

Standard Carton
5,000
5,000
5,000
5,000

Designed for use in hard aggregate and precast concrete. All pins are zinc plated for minimum level of corrosion resistance (mild service condition).
Each box of pins come packaged with one fuel cell.
© 2011 Powers Fasteners, Inc. All Rights Reserved. Deszglass is a registered trademark of Georgia Pacific. Trak-It is a registered trademark and Stick-E is a trademark of Powers Fasteners, Inc.
For current information please visit www.powers.com

Powers USA: (800) 524-3244 or (914) 235-6300

Canada: (905) 673-7295 or (514) 631-4216

www.powers.com

c

4

Trak-It C4

®

Trak-It C4

®

PRODUCT INFORMATION
High Performance Gas Fastening System

PRODUCT DESCRIPTION

SECTION CONTENTS

The Trak-It C4 and C4EX gas fastening systems were developed for use in high volume
production applications. Powerful rugged tools for fastening wood to concrete or steel.
The systems are designed for speed, increased power and durability.
The C4 CZ tool was designed for use with single shot powder pins together with gas
fastening technology. Operation of a gas fastening system does not require licensing.

GENERAL APPLICATIONS AND USES

Page No.

General Information...................... 5
Tool Specification .......................... 5
Performance Data.......................... 6
Pin Specifications .......................... 8
Ordering Information .................... 9

• Attaching wood to concrete, block or steel
• Attaching Steel to concrete, block or steel
• Attaching Plywood to Steel
• Attaching Steel track to concrete

FEATURES AND BENEFITS
+ No licensing required
+ Increased power and durability
+ Handles up to 2-9/16” length fasteners
+ Each fuel cell contains enough gas to install up to 800 fasteners
+ Pin diameter range 0.102” to 0.145”

Trak-It C4 Tool

APPROVALS AND LISTINGS
International Code Council , Evaluation Service (ICC-ES), ESR-2249

Trak-It C4EX Tool

GUIDE SPECIFICATIONS
CSI Divisions: 03151–Concrete Anchoring, 04081-Masonry Anchorage, 05090-Metal
Fastenings, 06090-Wood and Plastic Fastening. Gas fastening systems shall be Trak-It as
supplied by Powers Fasteners, Inc.

TOOL SPECIFICATIONS
Trak-It C4 Tool/C4EX Tool
Tool Body
Tool Length
Tool Weight
Pin Length
Pin Capacity
Power Capacity
Approximate Shots per Fuel Cell
Approximate Shots per Battery Charge

Precision Moulded Aluminum and Plastic
17-3/4"
9.7 lbs
2-9/16" Total Length
42 pins
120 Joules (C4) , 150 Joules (C4EX)
800 pins
5,500

Trak-It C4CZ Tool
SUITABLE BASE MATERIALS
Normal-Weight Concrete
Structural Lightweight Concrete
Concrete Masonry
Steel

Trak-It C4CZ Single Shot Tool
Tool Body
Tool Length
Tool Weight
Pin Length
Pin Capacity
Power Capacity
Approximate Shots per Fuel Cell
Approximate Shots per Battery Charge

Precision Moulded Aluminum and Plastic
17-3/4"
9.7 lbs
3" Total Length
Single Shot
150 Joules
800 pins
5,500

c

5

www.powers.com

Canada: (905) 673-7295 or (514) 631-4216

Powers USA: (800) 524-3244 or (914) 235-6300

Trak-It C4

®

PRODUCT INFORMATION
PERFORMANCE DATA
Allowable Load Capacities for Trak-It C4 Fasteners Installed in Normal Weight Concrete1,2,3

Minimum Concrete Compressive Strength (f'c)
Minimum
Spacing
inches
(mm)

Minimum
Edge
Distance
inches
(mm)

4
(101.6)

3
(76.2)

4
(101.6)

3
(76.2)

3/4
(19.1)

4
(101.6)

1
(25.4)

4
(101.6)

Shank
Type

Shank
Diameter
in.
(mm)

Minimum
Embedment
inches
(mm)

Straight

0.145
(3.68)

3/4
(19.1)

Straight

0.145
(3.68)

7/8
(22.2)

Step

0.145
(3.68)

3/4
(19.1)

Step

0.145
(3.68)

1
(25.4)

Taper

0.137
(3.48)

Taper

0.137
(3.48)

2,500 psi (17.2 mPa)

3,000 psi (20.7 mPa)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

65
(0.29)

105
(0.47)

70
(0.31)

110
(0.49)

125
(0.56)

105
(0.47)

135
(0.60)

110
(0.49)

80
(0.36)

220
(0.98)

90
(0.40)

235
(1.04)

130
(0.58)

245
(1.09)

140
(0.62)

270
(1.20)

1-3/4
(44.5)

80
(0.36)

90
(0.40)

90
(0.40)

100
(0.44)

1-3/4
(44.5)

90
(0.40)

70
(0.31)

100
(0.44)

80
(0.36)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.
2. The concrete thickness must be a minimum of 3 times the embedment depth of the fastener.
3. The tabulated allowable load values are for the fastener only. Wood or steel members connected to the steel substrate must be investigated in accordance with accepted design criteria.

Allowable Load Capacities for Trak-It C4 Fasteners Installed in Lightweight Concrete
and Structural Sand-Lightweight Concrete over Steel Deck1,2,3,4
Minimum Concrete Compressive Strength (f'c)
Shank
Type

Straight

Minimum
Shank
Embedment
Diameter
inches
in.
(mm)
(mm)

0.145
(3.68)

3/4
(19.1)

Minimum
Spacing
inches
(mm)

4
(101.6)

Minimum
Edge
Distance
inches
(mm)

1-1/8
(28.6)

2,500 psi (17.2 mPa)
Location

3,000 psi (20.7 mPa)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

Top

110
(0.49)

150
(0.67)

120
(0.53)

165
(0.73)

Lower Flute

70
(0.31)

180
(0.80)

80
(0.36)

200
(0.89)

Upper Flute

100
(0.44)

205
(0.91)

110
(0.49)

220
(0.98)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.
2. The steel deck must have a minimum base material thickness of No. 20 gage.
3. Concrete thickness must be a minimum of 3 times the embedment depth of the fastener. i.e, minimum yield strength, Fy, of 33 ksi, and conform to the Steel Deck Institute requirements for
Standard Wide Rib Deck, Type B.
4. The tabulated allowable load values are for the fastener only. Wood or steel members connected to the steel substrate must be investigated in accordance with accepted design criteria.

© 2011 Powers Fasteners, Inc. All Rights Reserved. Trak-It is a registered trademark of Powers Fasteners, Inc.

Powers USA: (800) 524-3244 or (914) 235-6300

Canada: (905) 673-7295 or (514) 631-4216

c

www.powers.com

6

Trak-It C4

®

PRODUCT INFORMATION

PERFORMANCE DATA
Allowable Load Capacities for Trak-It C4 Fasteners Installed in ASTM A36 Steel (minimum fut = 58 ksi)1
Fastener Type
(Style)

1/2" Steel Pin
.680 Steel Pin
.730 Steel Pin
1" Steel Pin
1-1/4" Steel Pin
2" Steel Pin
2" Steel Pin (ACQ)

Shank
Diameter
inches
(mm)

Minimum
Spacing
inches
(mm)

0.120
(3.05)
0.120
(3.05)
0.120
(3.05)
0.145
(3.68)
0.145
(3.68)
0.145
(3.68)
0.145
(3.68)

1
(25.4)

Minimum
Edge
Distance
inches
(mm)

Minimum
Steel
Member
Thickness
inches
(mm)

Tension
lbs
(kN)

Shear
lbs
(kN)

1/4
(6.4)

245
(1.09)
270
(1.20)
330
(1.46)
360
(1.60)
390
(1.73)
240
(1.06)
170
(0.75)

100
(0.44)
170
(0.75)
235
(1.04)
360
(1.60)
310
(1.38)
280
(1.24)
280
(1.24)

1/2
(12.7)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.

Allowable Load Capacities for C4 Coated Step Shank ACQ Pin in Normal-Weight Concrete 1,2
Minimum Concrete Compressive Strength
Fastener Type
(Style)

Minimum
Embedment
in.
(mm)

C4 Coated Step Shank ACQ Pin

3/4
(19.1)

4,000 psi (27.6 mPa)
Tension
lbs.
(kN)

Shear
lbs.
(kN)

200
(0.89)

280
(1.24)

1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such
as life safety or overhead.
2. Tabulated values are listed for the fastener only. Wood or steel members connected to the concrete substrate must be investigated in accordance with accepted design criteria.

c

7

www.powers.com

Canada: (905) 673-7295 or (514) 631-4216

Powers USA: (800) 524-3244 or (914) 235-6300

Trak-It C4

®

PRODUCT INFORMATION
ORDERING INFORMATION

C4 Pins - Straight and Taper Pins
Cat No.
55111
55113
55130
55132
55124
55128
55145
55147
55161
55163
55165
55116
55118
55172
55173
55174

Description
3/4” Pin
1” Pin
3/4" Straight Shank Pin
1” Straight Shank Pin
2-1/4” Pin
2-1/2” Pin
2-9/16” Taper Pin
2-9/16” Taper Pin w/ Washer
.500 Pin, (K)
.680 Pin, (K)
.730 Pin, (K)
1-1/4” Pin
1-1/2” Pin
1” Wood / Steel Pin, (K)
1-1/4” Wood / Steel Pin, (K)
2” Wood / Steel Pin, (K)

Shank
Diameter

STD Box

STD Ctn.

0.102
0.102
0.145
0.145
0.102
0.102
0.137
0.137
0.120
0.102
0.120
0.102
0.102
0.145
0.145
0.145

800
800
800
800
800
800
800
800
800
800
800
800
800
800
800
800

4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000

-

800

-

Shank
Diameter

STD Box

STD Ctn.

0.145/0.102
0.145/0.102
0.145/0.102
0.145/0.102
0.145/0.102
0.145/0.102

800
800
800
800
800
800

4000
4000
4000
4000
4000
4000

Shank
Diameter

STD Box

STD Ctn.

0.145
0.145
0.145

800
800
800

4000
4000
4000

(K) = knurled
Each box of pins come packaged with one fuel cell.
55149

1” Square Washer (Stick E)

C4 Step Shank Pins
Cat No.
55134
55136
55141
55138
55140
55139

Description
1-1/4” Step Shank Pin
1-1/2” Step Shank Pin
1-7/8” Step Shank Pin, (K)
2-3/8” Step Shank Pin
2-1/2” Step Shank Pin
2-1/4” Step Shank Pin

(K) = knurled
Each box of pins come packaged with one fuel cell.

C4 Coated Step Shank Pins (ACQ)
Cat No.
55167
55169
55171

Description
1” Step Shank Pin ACQ, (K)
1-1/4” Step Shank Pin ACQ, (K)
2” Step Shank Pin ACQ, (K)

(K) = knurled
Each box of pins come packaged with one fuel cell.

c

Powers USA: (800) 524-3244 or (914) 235-6300

Canada: (905) 673-7295 or (514) 631-4216

www.powers.com

8

Trak-It

®

PRODUCT INFORMATION

ORDERING INFORMATION

Cat No.

Description

STD Box

C4 Insulation Washer

55160

Cat No.

Description
2-1/4” Duplex Kicker Pin

55180

STD Ctn.
_

500

Shank
Diameter

STD Box

STD Ctn.

0.131”

800

4,000

Tools and Accessories
Trak-It C4 Tools
Cat No.
55112
55127
55133

Description
C4 Trak-It
C4 EX Trak-It
C4 CZ Trak-It

STD Box

STD Ctn.

1
1
1

1
1
1

Tools comes with case, charger and two batteries.

Trak-It C4 Fuel Cell
Cat No.
55115

Description
C4 Trak-It Fuel Cell

STD Box

STD Ctn.

12

72

Fuel cell works in temperatures down to 10°F.

© 2011 Powers Fasteners, Inc. All Rights Reserved. Trak-It is a registered trademark of Powers Fasteners, Inc. For the most current information Visit www.powers.com

9

www.powers.com

Canada: (905) 673-7295 or (514) 631-4216

c

Powers USA: (800) 524-3244 or (914) 235-6300

PRODUCT INFORMATION

Stick-E

Trak-It / Stick-E

®

Accessories for Trak-It C3

PRODUCT DESCRIPTION
The Stick-E fastening system uses Trak-It C3 gas technology with specially designed accessories for fastening typical applications
encountered by electricians and mechanical contractors. The Stick-E fastening system allows direct fastening through the fixture
with the magazine pin and accessory eliminating the need for drilling or anchoring.

APPLICATIONS GUIDE
Cable Tie Donut
Application For attaching small and large diameter cable ties to all types of walls and
ceilings including wood, steel beams, concrete and block. Ideal for strapping
wires and cable for hanging temporary lighting fixtures from all base materials.
(fits ties up to 1/4" wide.)
Contractor (s) Electricians
Suggested Pin Size (s) 780 Trak-It Step Shank Pins

Mini Conduit Clip
Application For attaching conduit and piping to steel beams, wood and concrete ceilings.
Contractor (s) Electricians
Suggested Pin Size (s) 780 Trak-It Step Shank Pins

Conduit Clip (One Hole Strap)
Application For attaching conduit and light duty pipe to walls and ceilings of any base
material including wood, steel beams, concrete and steel purlins.
Contractor (s) Electricians
Suggested Pin Size (s) 780 Trak-It Step Shank Pins

Bridal Ring
Application For suspending single or multiple wires and cable in runs from overhead ceilings
of all base materials including wood, steel beams, concrete and steel purlins.
Contractor (s) Electricians
Suggested Pin Size (s) 780 Trak-It Step Shank Pins
1" Trak-It Step Shank Pins

BX Clip
Application For attaching BX cable to walls and ceilings of any base material including
wood, steel beams, concrete and steel purlins.
Contractor (s) Cable Installers, Telecommunication Installers, Electricians
Suggested Pin Size (s) 780 Trak-It Step Shank Pins

Strap Washer
Application For attaching duct straps to suspend HVAC ductwork onto ceiling of various
base materials.
Contractor (s) Sheet Metal Contractors
Suggested Pin Size (s) 780 Trak-It Step Shank Pins

c

Powers USA: (800) 524-3244 or (914) 235-6300

Canada: (905) 673-7295 or (514) 631-4216

www.powers.com

10

Trak-It / Stick-E

®

PRODUCT INFORMATION

APPLICATIONS GUIDE
Rebar Basket Clip
Application For attaching rebar to existing concrete or wood forms prior to a pour.
Most popular in road and bridge construction and repair.
Contractor (s) Concrete Contractors
Suggested Pin Size (s) 780 Trak-It Step Shank Pins

Rod Hanger
Application Attaching rod overhead to steel beams, wood or concrete ceilings for the
purpose of suspending utilities, cable trays, conduit and pipe.
Contractor (s) Electricians, Plumbers, Mechanical Contractors
Suggested Pin Size (s) 780 Trak-It Step Shank Pins
Break-Free Pins

Right Angle Clip
Application For suspending acoustical ceiling systems or light fixtures.
Contractor (s) Acoustical and Ceiling Contractors
Suggested Pin Size (s) 780 Trak-It Step Shank Pins
Break-Free Pins

Insulation Washer
Application For attaching exterior foam insulation to all base materials including wood,
steel and concrete.
Contractor (s) Insulation Contractors, Waterproofers
Suggested Pin Size (s) 780 Trak-It Step Shank Pins
Break-Free Pins
1 1/4" Break Free Rolled Point Trak-It Pins (most base materials)
1 1/2" Break Free Rolled Point Trak-It Pins (most base materials)

Lathing Washer
Application For attaching wire lathe to wood, steel, concrete or block for the purpose of
troweling stucco in exterior applications or plaster in interior applications. Can also
be used as a general purpose washer.
Contractor (s) Drywall, Plaster, Exterior Siding Contractors
Suggested Pin Size (s) 780 Trak-It Step Shank Pins
1" Break Free Rolled Point Trak-It Pins (most base materials)
1 1/4" Break Free Rolled Point Trak-It Pins (most base materials)

Stainless Steel Sealing Washer
Application For attaching waterproofing membrane to foundations and roofing applications.
Contractor (s) Insulation Contractors, Waterproofers, Roofers
Suggested Pin Size (s) 3/4" Perma-Seal Coated Rolled Point Trak-It Pins (most base materials)
1" Perma-Seal Coated Rolled Point Trak-It Pins (most base materials)
TM

Denz-Tight Washer
Application For attaching Densglass® exterior sheathing to steel studs.
Contractor (s) Drywall Contractors
Suggested Pin Size (s) 1-3/8” Plywood/Densglass® Pins
* Densglass® is a registered trademark of Georgia Pacific.

c

11

www.powers.com

Canada: (905) 673-7295 or (514) 631-4216

Powers USA: (800) 524-3244 or (914) 235-6300

Trak-It / Stick-E

®

PRODUCT INFORMATION

PERFORMANCE DATA
Ultimate Load Capacities for Stick-E Accessories Installed with 780 Pin into Concrete, Concrete Block,
or Lightweight Concrete over Steel Deck1,2
Stick-E

Conduit Clip
BX Clip
Bridal Ring
Cable Tie
Insulation Washer
Rebar Clip
Strap Washer
Rod Hanger
Right Angle Clip

Minimum
Embed. Depth
hv
in.
(mm)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)

Ultimate Load
Tension
lbs.
(kN)

Shear
lbs.
(kN)

80
(0.35)

60
(0.27)

80
(0.35)

70
(0.31)

325
(1.44)

200
(0.89)

50
(0.22)

60
(0.27)

300
(1.33)

400
(1.78)

275
(1.22)

275
(1.22)

275
(1.22)

400
(1.78)

420
(1.86)

N/A

300
(1.33)

400
(1.78)

1. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 5.0 or greater to determine the allowable working load. Consideration of safety factors of 10.0 or
higher may be necessary depending on the application, such as life safety or overhead.
2. Minimum 2,000 psi Concrete or Concrete Block at time of installation.

Ultimate Load Capacities for Stick-E Accessories Installed with 780 Pin into A36 and A572 Steel1
Ultimate Load

Stick-E

Conduit BX Clip
Bridal Ring
Cable Tie
Strap Washer
Rod Hanger

Minimum
Embedment
Depth
hv
in.
(mm)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)

A36 Steel

A572 Steel

A572 Steel

(3/16" Thick)

(1/8" Thick)

(12 Gage)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

Tension
lbs.
(kN)

Shear
lbs.
(kN)

80
(0.35)
325
(1.44)
50
(0.22)
275
(1.22)
420
(1.86)

70
(0.35)
200
(0.89)
60
(0.27)
400
(1.78)

80
(0.35)
325
(1.44)
50
(0.22)
275
(1.22)
420
(1.86)

70
(0.35)
200
(0.89)
60
(0.27)
400
(1.78)

80
(0.35)
325
(1.44)
50
(0.22)
275
(1.22)
420
(1.86)

70
(0.35)
200
(0.89)
60
(0.27)
400
(1.78)

N/A

N/A

N/A

1. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 5.0 or greater to determine the allowable working load. Consideration of safety factors of 10.0 or
higher may be necessary depending on the application, such as life safety or overhead.

Ultimate Load Capacites for Electrical Boxes Installed with 780 Trak-It Step Shank Pin into Concrete
or Concrete Block1,2,3
Trak-It Pin

780

Minimum
Embed. Depth
hv
in.
(mm)

5/8
(15.9)

Number
of Pins
(Per Box)

Maximum
Spacing
in.
(mm)

Fastening
Pattern

2

1
(25.5)
2
(50.9)
2
(50.9)

Line

3
4

Triangle
Square/Diamond

Tension
lbs.
(kN)

Ultimate Load
Shear
Vert. Axis
lbs.
(kN)

Shear
Horiz. Axis
lbs.
(kN)

640
(2.85)
720
(3.20)
900
(4.00)

975
(4.34)
1,115
(4.96)
1,840
(8.18)

850
(3.78)
1,055
(4.69)
1,840
(8.18)

1. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 5.0 or greater to determine the allowable working load. Consideration of safety factors of 10.0 or higher may be
necessary depending on the application, such as life safety or overhead.
1. Installations for Nominal 16 Gage Electrical Boxes, All Finishes.
2. Minimum 2,000 psi Concrete of Concrete Block at time of installation.

c

Powers USA: (800) 524-3244 or (914) 235-6300

12

Canada: (905) 673-7295 or (514) 631-4216

www.powers.com

Trak-It / Stick-E

®

PRODUCT INFORMATION

ORDERING INFORMATION
Stick-E Mini Conduit Clip
Cat. No.
55064
55066
55068

Description
Mini Conduit Clip 1/2"
Mini Conduit Clip 3/4"
Mini Conduit Clip 1"

Standard Box
100
100
100

Standard Carton
1,000
1,000
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100
100
100

Standard Carton
1,000
1,000
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100
100
100

Standard Carton
1,000
1,000
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100
100

Standard Carton
1,000
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100

Standard Carton
1,000

Standard Box
100

Standard Carton
1,000

Stick-E Cable Tie Donut
Cat. No. Description
55076 Cable Tie Donut

Stick-E Conduit Clip (One Hole Strap)
Cat. No.
55059
55061
55063

Description
Conduit Clip 1/2"
Conduit Clip 3/4"
Conduit Clip 1"

Stick-E BX Clip
Cat. No. Description
55054 Stick-E 3/8" BX Clips

Stick-E Bridal Ring
Cat. No.
55094
55095
55096

Description
Bridal Ring 1 1/4"
Bridal Ring 1 1/2"
Bridal Ring 2"

Stick-E Strap Washer
Cat. No. Description
55062 Strap Washer 1/2" Diameter

Stick-E Rod Hanger
Cat. No. Description
55050 Rod Hanger 1/4"
55052 Rod Hanger 3/8"

Stick-E Rebar Basket Clip
Cat. No. Description
55070 #3 and #4 Bar

Stick-E Right Angle Clip
Cat. No. Description
55092 Right Angle Clip (Wirehole 0.278")

Stick-E Insulation Washer
Cat. No. Description
55042 Insulation Washer 1 7/16"

Stick-E Lathing Washer
Cat. No. Description
55040 Lathing Washer 1" with holes

Stick-E Stainless Steel Sealing Washer
Cat. No. Description
55043 SS Sealing Washer 3/4"

Stick-E Denz-TightTM Washer
Cat. No. Description
55157 Denz-TightTM Washer

© 2011 Powers Fasteners, Inc. All Rights Reserved. Stick-E is a registered trademark of Powers Fasteners, Inc. For the most current information Visit www.powers.com

13

www.powers.com

Canada: (905) 673-7295 or (514) 631-4216

c

Powers USA: (800) 524-3244 or (914) 235-6300



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2002:05:27 11:01:06Z
Modify Date                     : 2013:06:11 09:25:44-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 4.0 for Macintosh
Metadata Date                   : 2013:06:11 09:25:44-04:00
Format                          : application/pdf
Document ID                     : uuid:76ebc974-d3fe-484c-8821-bb1e92b1bbe2
Instance ID                     : uuid:874cdebe-74e1-bb43-8c6e-3c9fdcb5bee6
Page Count                      : 14
EXIF Metadata provided by EXIF.tools

Navigation menu