Product Detail Manual
2014-11-11
: Pdf 116620-Attachment 116620-Attachment 075352 Batch12 unilog
Open the PDF directly: View PDF .
Page Count: 14
Download | |
Open PDF In Browser | View PDF |
PRODUCT SUBMITTAL / SUBSTITUTION REQUEST TO: PROJECT: SPECIFIED ITEM: Section Page Paragraph Description P R O D U C T S U B M I T TA L / S U B S T I T U T I O N R E Q U E S T E D : Gas Actuated Fastening Systems from Powers Fasteners, Inc. The attached submittal package includes the product description, specifications, drawings, and performance data for use in the evaluation of the request. S U B M I T T E D B Y: Name: Signature: Company: Address: Date: Telephone: Fax: FOR USE BY THE ARCHITECT AND/OR ENGINEER ■ Approved ■ Approved as Noted ■ Not Approved (If not approved, please briefly explain why the product was not accepted.) By: Remarks: Date: Trak-It C3 ® Trak-It C3 PRODUCT INFORMATION ® Gas Fastening System PRODUCT DESCRIPTION SECTION CONTENTS The Trak-It C3 gas fastening system was developed for use in light-duty static applications, including attaching drywall track to concrete, block or steel, lath to concrete or block, furring strips to concrete or block, and plywood to concrete or block base materials. The system is designed for speed, efficiency and consistency. Operation of a gas fastening system does not require licensing. GENERAL APPLICATIONS AND USES Page No. General Information...................... 1 Tool Specification .......................... 1 Performance Data.......................... 2 Pin Specifications .......................... 4 Ordering Information .................... 4 • Attaching steel track to concrete, block or steel • Attaching plywood to concrete or block • Attaching lath to concrete, block or steel • Attaching furring strips to concrete or block FEATURES AND BENEFITS + No licensing required + Each fuel cell contains enough gas to install up to 1,000 fasteners + Available for use with Stick-E™ accessories + Short or long track versions Trak-It C3 Tool APPROVALS AND LISTINGS International Code Council, Evaluation Service (ICC-ES), ESR-2036 (Formerly ER-6157) City of Los Angeles (COLA) Research Report LARR-25523 GUIDE SPECIFICATIONS CSI Divisions: 03151–Concrete Anchoring, 04081-Masonry Anchorage, 05090-Metal Fastenings, 06090-Wood and Plastic Fastenings, 09260-Finishes. Gas fastening systems shall be Trak-It as supplied by Powers Fasteners, Inc. TOOL SPECIFICATIONS (Short Track) SUITABLE BASE MATERIALS Trak-It C3 Tool Tool Body Tool Length Tool Weight Pin Length Pin Capacity Power Capacity Approximate Shots per Fuel Cell Approximate Shots per Battery Charge Trak-It C3-ST Tool Precision Moulded Aluminum and Plastic 17" 8 lbs 1-1/2" total length 42 pins (22 pins - short track) 90 Joules 1,000 pins 5,500 Normal-Weight Concrete Structural Lightweight Concrete Concrete Masonry Steel c 1 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 or (914) 235-6300 Trak-It C3 ® PRODUCT INFORMATION PERFORMANCE DATA Allowable Load Capacities for Trak-It C3 Fasteners Installed in Normal-Weight Concrete1 Shank Diameter in. (mm) Min. Embed. in. (mm) 0.102 (2.59) 5/8 (15.9) 3/4 (19.1) 7/8 (22.2) 1 (25.4) Minimum Concrete Compressive Strength (f´c ) Min. Min. Edge 2,000 psi (13.8 MPa) 3,000 psi (20.7 MPa) 4,000 psi (27.6 MPa) 5,000 psi (34.5 MPa) Spacing Distance in. Tension Shear Tension Shear Tension Shear Tension Shear in. (mm) lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. (mm) (kN) (kN) (kN) (kN) (kN) (kN) (kN) (kN) 4 (101.6) 4 (101.6) 4 (101.6) 4 (101.6) 3 (76.2) 3 (76.2) 3 (76.2) 3 (76.2) 70 (0.31) 80 (0.36) 80 (0.36) 80 (0.36) 80 (0.36) 130 (0.58) 160 (0.71) 190 (0.85) 75 (0.33) 105 (0.47) 105 (0.47) 105 (0.47) 90 (0.40) 170 (0.76) 190 (0.85) 210 (0.93) 80 (0.36) 130 (0.58) 130 (0.58) 130 (0.58) 100 (0.44) 210 (0.93) 220 (0.98) 230 (1.02) 85 (0.38) 155 (0.69) 155 (0.69) 155 (0.69) 110 (0.49) 250 (1.11) 250 (1.11) 250 (1.11) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. Allowable Load Capacities for Trak-It C3 Installed in Structural Lightweight Concrete1 Shank Diameter in. (mm) Min. Embedment in. (mm) Minimum Spacing in. (mm) Minimum Edge Distance in. (mm) 0.102 (2.59) 3/4 (19.1) 7/8 (22.2) 1 (25.4) 4 (101.6) 4 (101.6) 4 (101.6) 6 (152.4) 6 (152.4) 6 (152.4) Minimum Concrete Compressive Strength (f´c ) 3,000 psi (20.7 MPa) 4,000 psi (27.6 MPa) 5,000 psi (34.5 MPa) Tension lbs. (kN) Shear lbs. (kN) Tension lbs. (kN) Shear lbs. (kN) Tension lbs. (kN) Shear lbs. (kN) 100 (0.44) 110 (0.49) 110 (0.49) 120 (0.53) 125 (0.56) 130 (0.58) 110 (0.49) 120 (0.53) 120 (0.53) 190 (0.85) 190 (0.85) 190 (0.85) 110 (0.49) 120 (0.53) 120 (0.53) 255 (1.13) 260 (1.16) 265 (1.18) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. Allowable Load Capacities for Trak-It C3 Fasteners Installed Through Steel Deck into Structural Lightweight Concrete1,2,3,4 Shank Diameter in. (mm) Min. Embedment in. (mm) Minimum Spacing in. (mm) Minimum Edge Distance in. (mm) 0.102 (2.59) 3/4 (19.1) 7/8 (22.2) 4 (101.6) 4 (101.6) 1 (25.4) 1 (25.4) Minimum Concrete Compressive Strength (f´c ) 3,000 psi (20.7 MPa) 4,000 psi (27.6 MPa) Tension lbs. (kN) Shear lbs. (kN) Tension lbs. (kN) Shear lbs. (kN) 80 (0.36) 85 (0.38) 105 (0.47) 120 (0.53) 85 (0.38) 90 (0.40) 115 (0.51) 130 (0.58) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. 2. For fasteners installed through steel deck, the minimum edge distance is 1 inch from the edge of the deck rib and 6 inches from the end of the deck. Allowable shear loads may be applied in any direction. 3. Fasteners are permitted to be installed in the lower or upper flute of the steel deck provided that proper installation procedures are maintained. 4. The allowable values are applicable to fasteners installed through the underside of a steel deck at the ribs and into minimum 3,000 psi structural lightweight concrete. The steel deck must have a minimum base-metal thickness of 0.034 inch (20 gage) with a minimum yield point, Fy, of 33,000 psi and conform to the Steel Deck institute requirements for Standard Wide Rib Deck. STRUCTUAL SAND-LIGHTWEIGHT CONCRETE OVER STEEL DECK (MINIMUM 3,000 PSI) c Powers USA: (800) 524-3244 or (914) 235-6300 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 2 Trak-It C3 ® PRODUCT INFORMATION PERFORMANCE DATA Allowable Load Capacities for Trak-It C3 Fasteners Installed in Concrete Masonry Units1,2 Shank Diameter in. (mm) Min. Embedment in. (mm) Minimum Spacing in. (mm) Minimum Edge Distance in. (mm) 0.102 (2.59) 7/8 (22.2) 1 (25.4) 4 (101.6) 4 (101.6) 3 3/4 (95.3) 3 3/4 (95.3) Hollow or Grouted (Any Location) f´m ≥ 1,500 psi (10.4 MPa) Tension lbs. (kN) Shear lbs. (kN) 65 (0.29) 65 (0.29) 80 (0.36) 120 (0.53) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. 2. Tabulated load values are for fasteners installed in minimum 6-inch wide, Minimum Grade N, Type II lightweight, medium and normal-weight concrete masonry units conforming to ASTM C 90. The face shell thickness of the concrete masonry units shall be a minimum of 1-1/4 inch. Allowable Load Capacities for Trak-It C3 Fasteners Installed in ASTM A 36 Steel1,2,3 Fastener Type (Style) Minimum Minimum Spacing Edge Distance in. in. (mm) (mm) 1/2 inch Steel Pin 1 (25.4) 3/16" Tension Shear lbs. lbs. (kN) (kN) 1/2 (12.7) 115 (0.51) 260 (1.16) Nominal Steel Thickness 1/4" 3/8" Tension Shear Tension Shear lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) 165 (0.73) 260 (1.16) 175 (0.78) 255 (1.13) 1/2" Tension Shear lbs. lbs. (kN) (kN) 175 (0.78) 205 (0.91) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. 2. Steel members must have a minimum yield strength, fy, of 36,000 psi 3. Fasteners installed in 1/2-inch-thick steel must have a minimum embedment depth of 3/8-inch. Allowable Load Capacities for Trak-It C3 Fasteners Installed in ASTM A 572 Steel1,2,3 Fastener Type (Style) Minimum Minimum Spacing Edge Distance in. in. (mm) (mm) 1/2 inch Steel Pin 1 (25.4) 3/16" Tension Shear lbs. lbs. (kN) (kN) 1/2 (12.7) 145 (0.64) 290 (1.29) Nominal Steel Thickness 1/4" 3/8" Tension Shear Tension Shear lbs. lbs. lbs. lbs. (kN) (kN) (kN) (kN) 175 (0.78) 290 (1.29) 215 (0.96) 270 (1.20) 1/2" Tension Shear lbs. lbs. (kN) (kN) 165 (0.73) 250 (1.11) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. 2. Steel members must have a minimum yield strength, fy, of 50,000 psi 3. Fasteners installed in 1/2-inch-thick steel must have a minimum embedment depth of 3/8-inch. Allowable Load Capacities for Trak-It C3 Plywood Pin Installed Through Plywood into Steel Track1 Fastener Type (Style) Shank Diameter in. (mm) 16 Gage Steel Track Tension lbs. (kN) 18 Gage Steel Track Tension lbs. (kN) Plywood to Steel Pin 0.102 (2.59) 65 (0.29) 40 (0.18) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. Allowable Negative Transverse Loads Using Plywood/Densglass® Pin and Denz-TightTM Washer Fasteners1 Fastener Type (style) Plywood/Densglass® 0.102” Diameter Sheathing Minimum Steel Stud Thickness (gage) Minimum Stud Spacing (inches) Fastener Spacing (inches) Allowable Negative Pressure (psf) Densglass® Gold 16 24 6-1/2 50 1. Allowable load capacities are based on a minimum safety factor of 3.0. Densglass® is a registered trademark of Georgia Pacific c 3 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 or (914) 235-6300 PRODUCT INFORMATION Trak-It C3 ® ORDERING INFORMATION C3 Tools and Accessories Trak-It C3 Tools Cat No. 55011 55002 Discription STD Box STD Ctn. 1 1 1 1 STD Box STD Ctn. 20 80 C3 Trak-It C3-ST Trak-It Tool comes with case, charger and two batteries. Trak-It Fuel Cell Discription Cat No. 55010 C3 Trak-It Fuel Cell Fuel cell works in temperatures down to 10°F. Trak-It Pole Tools Cat No. Discription STD Box STD Ctn. 55048 55051 55053 55055 6’ Pole Tool & One Trak-It C3-ST (Short Track) Tool 8’ Pole Tool & One Trak-It C3-ST (Short Track) Tool 6’ Pole Tool 8’ Pole Tool 1 1 1 1 1 1 1 1 1/2" Steel Pin (Step Shank with Rolled Point) Cat. No. Description 55020 1/2" Steel Pin Shank Diameter 0.120/0.102" Standard Box 1,000 Standard Carton 5,000 Designed for use in A36 and A572 steel beams, purlins, and bar joist. All pins are zinc plated for minimum level of corrosion resistance (mild service condition). Each box of pins come packaged with one fuel cell. Standard Pins (Smooth Shank with Rolled Point) Cat. No. 55022B 55024 55026 55028 Description 3/4" Black 1" Zinc 1 1/4" Zinc 1 1/2" Zinc Shank Diameter 0.102" 0.102" 0.102" 0.102" Standard Box 1,000 1,000 1,000 1,000 Standard Carton 5,000 5,000 5,000 5,000 Designed for use in concrete and masonry. All pins are zinc plated or coated with black oxide for a minimum level of corrosion resistance (mild service condition). Each box of pins come packaged with one fuel cell. Standard Pins with Break-free Collation (Smooth Shank with Rolled Point) Cat. No. 55032 55033 55034 55035 Description 3/4" Black 1" Zinc 1 1/4" Zinc 1 1/2" Zinc Shank Diameter 0.102" 0.102" 0.102" 0.102" Standard Box 1,000 1,000 1,000 1,000 Standard Carton 5,000 5,000 5,000 5,000 Designed for use in concrete and masonry. All pins are zinc plated or coated with black oxide for a minimum level of corrosion resistance (mild service condition). Plastic collation breaks completely free of pin during installation. Each box of pins come packaged with one fuel cell. Plywood/Densglass® to Steel Pin (Spiral Knurl Shank with Rolled Point) Cat. No. Description 55036 1 3/8" Zinc Shank Diameter 0.102" Standard Box 1,000 Standard Carton 5,000 Designed for use to attach plywood to light gage steel framing. All pins are zinc plated for a minimum level of corrosion resistance (mild service condition). Each box of pins come packaged with one fuel cell. Stick-E Pins (Step Shank) Cat. No. 55080 55081 55087 55085 Description 780 Step Shank Pin 1” Step Shank Pin 730 Step Shank Pin 680 Step Shank Pin Shank Diameter 0.120/0.102" 0.120/0.088" 0.120/0.102" 0.120/0.102" Standard Box 1,000 1,000 1,000 1,000 Standard Carton 5,000 5,000 5,000 5,000 Designed for use in hard aggregate and precast concrete. All pins are zinc plated for minimum level of corrosion resistance (mild service condition). Each box of pins come packaged with one fuel cell. © 2011 Powers Fasteners, Inc. All Rights Reserved. Deszglass is a registered trademark of Georgia Pacific. Trak-It is a registered trademark and Stick-E is a trademark of Powers Fasteners, Inc. For current information please visit www.powers.com Powers USA: (800) 524-3244 or (914) 235-6300 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com c 4 Trak-It C4 ® Trak-It C4 ® PRODUCT INFORMATION High Performance Gas Fastening System PRODUCT DESCRIPTION SECTION CONTENTS The Trak-It C4 and C4EX gas fastening systems were developed for use in high volume production applications. Powerful rugged tools for fastening wood to concrete or steel. The systems are designed for speed, increased power and durability. The C4 CZ tool was designed for use with single shot powder pins together with gas fastening technology. Operation of a gas fastening system does not require licensing. GENERAL APPLICATIONS AND USES Page No. General Information...................... 5 Tool Specification .......................... 5 Performance Data.......................... 6 Pin Specifications .......................... 8 Ordering Information .................... 9 • Attaching wood to concrete, block or steel • Attaching Steel to concrete, block or steel • Attaching Plywood to Steel • Attaching Steel track to concrete FEATURES AND BENEFITS + No licensing required + Increased power and durability + Handles up to 2-9/16” length fasteners + Each fuel cell contains enough gas to install up to 800 fasteners + Pin diameter range 0.102” to 0.145” Trak-It C4 Tool APPROVALS AND LISTINGS International Code Council , Evaluation Service (ICC-ES), ESR-2249 Trak-It C4EX Tool GUIDE SPECIFICATIONS CSI Divisions: 03151–Concrete Anchoring, 04081-Masonry Anchorage, 05090-Metal Fastenings, 06090-Wood and Plastic Fastening. Gas fastening systems shall be Trak-It as supplied by Powers Fasteners, Inc. TOOL SPECIFICATIONS Trak-It C4 Tool/C4EX Tool Tool Body Tool Length Tool Weight Pin Length Pin Capacity Power Capacity Approximate Shots per Fuel Cell Approximate Shots per Battery Charge Precision Moulded Aluminum and Plastic 17-3/4" 9.7 lbs 2-9/16" Total Length 42 pins 120 Joules (C4) , 150 Joules (C4EX) 800 pins 5,500 Trak-It C4CZ Tool SUITABLE BASE MATERIALS Normal-Weight Concrete Structural Lightweight Concrete Concrete Masonry Steel Trak-It C4CZ Single Shot Tool Tool Body Tool Length Tool Weight Pin Length Pin Capacity Power Capacity Approximate Shots per Fuel Cell Approximate Shots per Battery Charge Precision Moulded Aluminum and Plastic 17-3/4" 9.7 lbs 3" Total Length Single Shot 150 Joules 800 pins 5,500 c 5 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 or (914) 235-6300 Trak-It C4 ® PRODUCT INFORMATION PERFORMANCE DATA Allowable Load Capacities for Trak-It C4 Fasteners Installed in Normal Weight Concrete1,2,3 Minimum Concrete Compressive Strength (f'c) Minimum Spacing inches (mm) Minimum Edge Distance inches (mm) 4 (101.6) 3 (76.2) 4 (101.6) 3 (76.2) 3/4 (19.1) 4 (101.6) 1 (25.4) 4 (101.6) Shank Type Shank Diameter in. (mm) Minimum Embedment inches (mm) Straight 0.145 (3.68) 3/4 (19.1) Straight 0.145 (3.68) 7/8 (22.2) Step 0.145 (3.68) 3/4 (19.1) Step 0.145 (3.68) 1 (25.4) Taper 0.137 (3.48) Taper 0.137 (3.48) 2,500 psi (17.2 mPa) 3,000 psi (20.7 mPa) Tension lbs. (kN) Shear lbs. (kN) Tension lbs. (kN) Shear lbs. (kN) 65 (0.29) 105 (0.47) 70 (0.31) 110 (0.49) 125 (0.56) 105 (0.47) 135 (0.60) 110 (0.49) 80 (0.36) 220 (0.98) 90 (0.40) 235 (1.04) 130 (0.58) 245 (1.09) 140 (0.62) 270 (1.20) 1-3/4 (44.5) 80 (0.36) 90 (0.40) 90 (0.40) 100 (0.44) 1-3/4 (44.5) 90 (0.40) 70 (0.31) 100 (0.44) 80 (0.36) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. 2. The concrete thickness must be a minimum of 3 times the embedment depth of the fastener. 3. The tabulated allowable load values are for the fastener only. Wood or steel members connected to the steel substrate must be investigated in accordance with accepted design criteria. Allowable Load Capacities for Trak-It C4 Fasteners Installed in Lightweight Concrete and Structural Sand-Lightweight Concrete over Steel Deck1,2,3,4 Minimum Concrete Compressive Strength (f'c) Shank Type Straight Minimum Shank Embedment Diameter inches in. (mm) (mm) 0.145 (3.68) 3/4 (19.1) Minimum Spacing inches (mm) 4 (101.6) Minimum Edge Distance inches (mm) 1-1/8 (28.6) 2,500 psi (17.2 mPa) Location 3,000 psi (20.7 mPa) Tension lbs. (kN) Shear lbs. (kN) Tension lbs. (kN) Shear lbs. (kN) Top 110 (0.49) 150 (0.67) 120 (0.53) 165 (0.73) Lower Flute 70 (0.31) 180 (0.80) 80 (0.36) 200 (0.89) Upper Flute 100 (0.44) 205 (0.91) 110 (0.49) 220 (0.98) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. 2. The steel deck must have a minimum base material thickness of No. 20 gage. 3. Concrete thickness must be a minimum of 3 times the embedment depth of the fastener. i.e, minimum yield strength, Fy, of 33 ksi, and conform to the Steel Deck Institute requirements for Standard Wide Rib Deck, Type B. 4. The tabulated allowable load values are for the fastener only. Wood or steel members connected to the steel substrate must be investigated in accordance with accepted design criteria. © 2011 Powers Fasteners, Inc. All Rights Reserved. Trak-It is a registered trademark of Powers Fasteners, Inc. Powers USA: (800) 524-3244 or (914) 235-6300 Canada: (905) 673-7295 or (514) 631-4216 c www.powers.com 6 Trak-It C4 ® PRODUCT INFORMATION PERFORMANCE DATA Allowable Load Capacities for Trak-It C4 Fasteners Installed in ASTM A36 Steel (minimum fut = 58 ksi)1 Fastener Type (Style) 1/2" Steel Pin .680 Steel Pin .730 Steel Pin 1" Steel Pin 1-1/4" Steel Pin 2" Steel Pin 2" Steel Pin (ACQ) Shank Diameter inches (mm) Minimum Spacing inches (mm) 0.120 (3.05) 0.120 (3.05) 0.120 (3.05) 0.145 (3.68) 0.145 (3.68) 0.145 (3.68) 0.145 (3.68) 1 (25.4) Minimum Edge Distance inches (mm) Minimum Steel Member Thickness inches (mm) Tension lbs (kN) Shear lbs (kN) 1/4 (6.4) 245 (1.09) 270 (1.20) 330 (1.46) 360 (1.60) 390 (1.73) 240 (1.06) 170 (0.75) 100 (0.44) 170 (0.75) 235 (1.04) 360 (1.60) 310 (1.38) 280 (1.24) 280 (1.24) 1/2 (12.7) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. Allowable Load Capacities for C4 Coated Step Shank ACQ Pin in Normal-Weight Concrete 1,2 Minimum Concrete Compressive Strength Fastener Type (Style) Minimum Embedment in. (mm) C4 Coated Step Shank ACQ Pin 3/4 (19.1) 4,000 psi (27.6 mPa) Tension lbs. (kN) Shear lbs. (kN) 200 (0.89) 280 (1.24) 1. Allowable load capacities listed are calculated using a safety factor of 5.0 or greater. Consideration of safety factors of 10 or higher may be necessary depending on the application, such as life safety or overhead. 2. Tabulated values are listed for the fastener only. Wood or steel members connected to the concrete substrate must be investigated in accordance with accepted design criteria. c 7 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 or (914) 235-6300 Trak-It C4 ® PRODUCT INFORMATION ORDERING INFORMATION C4 Pins - Straight and Taper Pins Cat No. 55111 55113 55130 55132 55124 55128 55145 55147 55161 55163 55165 55116 55118 55172 55173 55174 Description 3/4” Pin 1” Pin 3/4" Straight Shank Pin 1” Straight Shank Pin 2-1/4” Pin 2-1/2” Pin 2-9/16” Taper Pin 2-9/16” Taper Pin w/ Washer .500 Pin, (K) .680 Pin, (K) .730 Pin, (K) 1-1/4” Pin 1-1/2” Pin 1” Wood / Steel Pin, (K) 1-1/4” Wood / Steel Pin, (K) 2” Wood / Steel Pin, (K) Shank Diameter STD Box STD Ctn. 0.102 0.102 0.145 0.145 0.102 0.102 0.137 0.137 0.120 0.102 0.120 0.102 0.102 0.145 0.145 0.145 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 - 800 - Shank Diameter STD Box STD Ctn. 0.145/0.102 0.145/0.102 0.145/0.102 0.145/0.102 0.145/0.102 0.145/0.102 800 800 800 800 800 800 4000 4000 4000 4000 4000 4000 Shank Diameter STD Box STD Ctn. 0.145 0.145 0.145 800 800 800 4000 4000 4000 (K) = knurled Each box of pins come packaged with one fuel cell. 55149 1” Square Washer (Stick E) C4 Step Shank Pins Cat No. 55134 55136 55141 55138 55140 55139 Description 1-1/4” Step Shank Pin 1-1/2” Step Shank Pin 1-7/8” Step Shank Pin, (K) 2-3/8” Step Shank Pin 2-1/2” Step Shank Pin 2-1/4” Step Shank Pin (K) = knurled Each box of pins come packaged with one fuel cell. C4 Coated Step Shank Pins (ACQ) Cat No. 55167 55169 55171 Description 1” Step Shank Pin ACQ, (K) 1-1/4” Step Shank Pin ACQ, (K) 2” Step Shank Pin ACQ, (K) (K) = knurled Each box of pins come packaged with one fuel cell. c Powers USA: (800) 524-3244 or (914) 235-6300 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 8 Trak-It ® PRODUCT INFORMATION ORDERING INFORMATION Cat No. Description STD Box C4 Insulation Washer 55160 Cat No. Description 2-1/4” Duplex Kicker Pin 55180 STD Ctn. _ 500 Shank Diameter STD Box STD Ctn. 0.131” 800 4,000 Tools and Accessories Trak-It C4 Tools Cat No. 55112 55127 55133 Description C4 Trak-It C4 EX Trak-It C4 CZ Trak-It STD Box STD Ctn. 1 1 1 1 1 1 Tools comes with case, charger and two batteries. Trak-It C4 Fuel Cell Cat No. 55115 Description C4 Trak-It Fuel Cell STD Box STD Ctn. 12 72 Fuel cell works in temperatures down to 10°F. © 2011 Powers Fasteners, Inc. All Rights Reserved. Trak-It is a registered trademark of Powers Fasteners, Inc. For the most current information Visit www.powers.com 9 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 c Powers USA: (800) 524-3244 or (914) 235-6300 PRODUCT INFORMATION Stick-E Trak-It / Stick-E ® Accessories for Trak-It C3 PRODUCT DESCRIPTION The Stick-E fastening system uses Trak-It C3 gas technology with specially designed accessories for fastening typical applications encountered by electricians and mechanical contractors. The Stick-E fastening system allows direct fastening through the fixture with the magazine pin and accessory eliminating the need for drilling or anchoring. APPLICATIONS GUIDE Cable Tie Donut Application For attaching small and large diameter cable ties to all types of walls and ceilings including wood, steel beams, concrete and block. Ideal for strapping wires and cable for hanging temporary lighting fixtures from all base materials. (fits ties up to 1/4" wide.) Contractor (s) Electricians Suggested Pin Size (s) 780 Trak-It Step Shank Pins Mini Conduit Clip Application For attaching conduit and piping to steel beams, wood and concrete ceilings. Contractor (s) Electricians Suggested Pin Size (s) 780 Trak-It Step Shank Pins Conduit Clip (One Hole Strap) Application For attaching conduit and light duty pipe to walls and ceilings of any base material including wood, steel beams, concrete and steel purlins. Contractor (s) Electricians Suggested Pin Size (s) 780 Trak-It Step Shank Pins Bridal Ring Application For suspending single or multiple wires and cable in runs from overhead ceilings of all base materials including wood, steel beams, concrete and steel purlins. Contractor (s) Electricians Suggested Pin Size (s) 780 Trak-It Step Shank Pins 1" Trak-It Step Shank Pins BX Clip Application For attaching BX cable to walls and ceilings of any base material including wood, steel beams, concrete and steel purlins. Contractor (s) Cable Installers, Telecommunication Installers, Electricians Suggested Pin Size (s) 780 Trak-It Step Shank Pins Strap Washer Application For attaching duct straps to suspend HVAC ductwork onto ceiling of various base materials. Contractor (s) Sheet Metal Contractors Suggested Pin Size (s) 780 Trak-It Step Shank Pins c Powers USA: (800) 524-3244 or (914) 235-6300 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com 10 Trak-It / Stick-E ® PRODUCT INFORMATION APPLICATIONS GUIDE Rebar Basket Clip Application For attaching rebar to existing concrete or wood forms prior to a pour. Most popular in road and bridge construction and repair. Contractor (s) Concrete Contractors Suggested Pin Size (s) 780 Trak-It Step Shank Pins Rod Hanger Application Attaching rod overhead to steel beams, wood or concrete ceilings for the purpose of suspending utilities, cable trays, conduit and pipe. Contractor (s) Electricians, Plumbers, Mechanical Contractors Suggested Pin Size (s) 780 Trak-It Step Shank Pins Break-Free Pins Right Angle Clip Application For suspending acoustical ceiling systems or light fixtures. Contractor (s) Acoustical and Ceiling Contractors Suggested Pin Size (s) 780 Trak-It Step Shank Pins Break-Free Pins Insulation Washer Application For attaching exterior foam insulation to all base materials including wood, steel and concrete. Contractor (s) Insulation Contractors, Waterproofers Suggested Pin Size (s) 780 Trak-It Step Shank Pins Break-Free Pins 1 1/4" Break Free Rolled Point Trak-It Pins (most base materials) 1 1/2" Break Free Rolled Point Trak-It Pins (most base materials) Lathing Washer Application For attaching wire lathe to wood, steel, concrete or block for the purpose of troweling stucco in exterior applications or plaster in interior applications. Can also be used as a general purpose washer. Contractor (s) Drywall, Plaster, Exterior Siding Contractors Suggested Pin Size (s) 780 Trak-It Step Shank Pins 1" Break Free Rolled Point Trak-It Pins (most base materials) 1 1/4" Break Free Rolled Point Trak-It Pins (most base materials) Stainless Steel Sealing Washer Application For attaching waterproofing membrane to foundations and roofing applications. Contractor (s) Insulation Contractors, Waterproofers, Roofers Suggested Pin Size (s) 3/4" Perma-Seal Coated Rolled Point Trak-It Pins (most base materials) 1" Perma-Seal Coated Rolled Point Trak-It Pins (most base materials) TM Denz-Tight Washer Application For attaching Densglass® exterior sheathing to steel studs. Contractor (s) Drywall Contractors Suggested Pin Size (s) 1-3/8” Plywood/Densglass® Pins * Densglass® is a registered trademark of Georgia Pacific. c 11 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 Powers USA: (800) 524-3244 or (914) 235-6300 Trak-It / Stick-E ® PRODUCT INFORMATION PERFORMANCE DATA Ultimate Load Capacities for Stick-E Accessories Installed with 780 Pin into Concrete, Concrete Block, or Lightweight Concrete over Steel Deck1,2 Stick-E Conduit Clip BX Clip Bridal Ring Cable Tie Insulation Washer Rebar Clip Strap Washer Rod Hanger Right Angle Clip Minimum Embed. Depth hv in. (mm) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) Ultimate Load Tension lbs. (kN) Shear lbs. (kN) 80 (0.35) 60 (0.27) 80 (0.35) 70 (0.31) 325 (1.44) 200 (0.89) 50 (0.22) 60 (0.27) 300 (1.33) 400 (1.78) 275 (1.22) 275 (1.22) 275 (1.22) 400 (1.78) 420 (1.86) N/A 300 (1.33) 400 (1.78) 1. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 5.0 or greater to determine the allowable working load. Consideration of safety factors of 10.0 or higher may be necessary depending on the application, such as life safety or overhead. 2. Minimum 2,000 psi Concrete or Concrete Block at time of installation. Ultimate Load Capacities for Stick-E Accessories Installed with 780 Pin into A36 and A572 Steel1 Ultimate Load Stick-E Conduit BX Clip Bridal Ring Cable Tie Strap Washer Rod Hanger Minimum Embedment Depth hv in. (mm) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) A36 Steel A572 Steel A572 Steel (3/16" Thick) (1/8" Thick) (12 Gage) Tension lbs. (kN) Shear lbs. (kN) Tension lbs. (kN) Shear lbs. (kN) Tension lbs. (kN) Shear lbs. (kN) 80 (0.35) 325 (1.44) 50 (0.22) 275 (1.22) 420 (1.86) 70 (0.35) 200 (0.89) 60 (0.27) 400 (1.78) 80 (0.35) 325 (1.44) 50 (0.22) 275 (1.22) 420 (1.86) 70 (0.35) 200 (0.89) 60 (0.27) 400 (1.78) 80 (0.35) 325 (1.44) 50 (0.22) 275 (1.22) 420 (1.86) 70 (0.35) 200 (0.89) 60 (0.27) 400 (1.78) N/A N/A N/A 1. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 5.0 or greater to determine the allowable working load. Consideration of safety factors of 10.0 or higher may be necessary depending on the application, such as life safety or overhead. Ultimate Load Capacites for Electrical Boxes Installed with 780 Trak-It Step Shank Pin into Concrete or Concrete Block1,2,3 Trak-It Pin 780 Minimum Embed. Depth hv in. (mm) 5/8 (15.9) Number of Pins (Per Box) Maximum Spacing in. (mm) Fastening Pattern 2 1 (25.5) 2 (50.9) 2 (50.9) Line 3 4 Triangle Square/Diamond Tension lbs. (kN) Ultimate Load Shear Vert. Axis lbs. (kN) Shear Horiz. Axis lbs. (kN) 640 (2.85) 720 (3.20) 900 (4.00) 975 (4.34) 1,115 (4.96) 1,840 (8.18) 850 (3.78) 1,055 (4.69) 1,840 (8.18) 1. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 5.0 or greater to determine the allowable working load. Consideration of safety factors of 10.0 or higher may be necessary depending on the application, such as life safety or overhead. 1. Installations for Nominal 16 Gage Electrical Boxes, All Finishes. 2. Minimum 2,000 psi Concrete of Concrete Block at time of installation. c Powers USA: (800) 524-3244 or (914) 235-6300 12 Canada: (905) 673-7295 or (514) 631-4216 www.powers.com Trak-It / Stick-E ® PRODUCT INFORMATION ORDERING INFORMATION Stick-E Mini Conduit Clip Cat. No. 55064 55066 55068 Description Mini Conduit Clip 1/2" Mini Conduit Clip 3/4" Mini Conduit Clip 1" Standard Box 100 100 100 Standard Carton 1,000 1,000 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 100 100 Standard Carton 1,000 1,000 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 100 100 Standard Carton 1,000 1,000 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 100 Standard Carton 1,000 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 Standard Carton 1,000 Standard Box 100 Standard Carton 1,000 Stick-E Cable Tie Donut Cat. No. Description 55076 Cable Tie Donut Stick-E Conduit Clip (One Hole Strap) Cat. No. 55059 55061 55063 Description Conduit Clip 1/2" Conduit Clip 3/4" Conduit Clip 1" Stick-E BX Clip Cat. No. Description 55054 Stick-E 3/8" BX Clips Stick-E Bridal Ring Cat. No. 55094 55095 55096 Description Bridal Ring 1 1/4" Bridal Ring 1 1/2" Bridal Ring 2" Stick-E Strap Washer Cat. No. Description 55062 Strap Washer 1/2" Diameter Stick-E Rod Hanger Cat. No. Description 55050 Rod Hanger 1/4" 55052 Rod Hanger 3/8" Stick-E Rebar Basket Clip Cat. No. Description 55070 #3 and #4 Bar Stick-E Right Angle Clip Cat. No. Description 55092 Right Angle Clip (Wirehole 0.278") Stick-E Insulation Washer Cat. No. Description 55042 Insulation Washer 1 7/16" Stick-E Lathing Washer Cat. No. Description 55040 Lathing Washer 1" with holes Stick-E Stainless Steel Sealing Washer Cat. No. Description 55043 SS Sealing Washer 3/4" Stick-E Denz-TightTM Washer Cat. No. Description 55157 Denz-TightTM Washer © 2011 Powers Fasteners, Inc. All Rights Reserved. Stick-E is a registered trademark of Powers Fasteners, Inc. For the most current information Visit www.powers.com 13 www.powers.com Canada: (905) 673-7295 or (514) 631-4216 c Powers USA: (800) 524-3244 or (914) 235-6300
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2002:05:27 11:01:06Z Modify Date : 2013:06:11 09:25:44-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 4.0 for Macintosh Metadata Date : 2013:06:11 09:25:44-04:00 Format : application/pdf Document ID : uuid:76ebc974-d3fe-484c-8821-bb1e92b1bbe2 Instance ID : uuid:874cdebe-74e1-bb43-8c6e-3c9fdcb5bee6 Page Count : 14EXIF Metadata provided by EXIF.tools