Brochure
97101-Catalog 97101-Catalog 97101-Catalog 785901 Batch6 unilog cesco-content
2014-07-30
: Pdf 117125-Brochure 117125-Brochure 785901 Batch6 unilog
Open the PDF directly: View PDF .
Page Count: 5
Download | |
Open PDF In Browser | View PDF |
Selection Information Molded Case Circuit Breakers Class 500, 600, 800 www.schneider-electric.us 100 A F-Frame Circuit Breaker Type Number of Poles Current Range PowerPact 250 A J-Frame PowerPact 250 A Q-Frame FI FY JD JG JJ JL QB QD QG QJ 2, 3 1 2,3a 2,3a 2,3a 2,3a 2, 3 2, 3 2, 3 2, 3 20–100 15–30 150–250 A 150–250 A 150–250 A 150–250 A 70–250b 70–250b 70–250b 70–250b 100 Interrupting Ratings UL/CSA/NOM Rating (kA RMS) (50/60 Hz) 240 Vac 200 14 25 65 100 125 10 25 65 480Y/277 Vac 200 14 18 35 65 100 — — — — 480 Vac 200 — 18 35 65 100 — — — — 600Y/347 Vac 100 — 14 18 25 50 — — — — 600 Vac 100 — 14 18 25 50 — — — — 250 Vdc — — 20 20 20 20 — — — — 500 Vdcc — — — 20 — — — — — — 240 Vac — — 25/25 65/65 100/100 125/125 10/5 10/5 10/5 10/5 18/18 35/35 65/65 100/100 10/5 10/5 10/5 10/5 DC Ratings IEC Rating (kA RMS) Icu/lcsd 415 Vac IEC 50/60 Hz 6/1.5 — For additional IEC ratings, see the Supplemental Digest. Special Ratings Fed. Specs W-C-375B/GEN X — X X X X X X X X HACR (2P, 3P) — — X X X X X X X — Unit Mount X — X X X X X X X X I-Line® X X X X X X X X X X Rear Connection — — X X X X — — — — Drawout — — X X X X — — — — Optional Lugs X — X X X X — — — — Connections/Terminations Shunt Trip Xf — X X X X — — — — Undervoltage Trip Xf — X X X X — — — — Auxiliary Switches Xf — X X X X — — — — Alarm Switch Xf — X X X X — — — — Motor Operator X — X X X X — — — — Handle Operators — — X X X X — — — — Mechanical Interlocks (3P) — — X X X X X X X X Handle Padlock Attachment X X X X X X X X X X Cylinder Lock (3Pf) — — — — — — — — — — Optional GF Protectione X — — — — — — — — — MINIATURE AND MOLDED CASE CIRCUIT BREAKERS Accessories and Modifications Trip System Type Thermal-magnetic X X X X X X X X X X Instantaneous-only (MCP) — — — Xg Xg — — — — — — — X X X X X — — — Electronic — — — — — — — — — — General Purpose (NEMA 1) X — X X X — X X X X Raintight (NEMA 3R) X — X X X — X X X X Dust-tight (NEMA 12) X — X X X — — — — — Watertight (NEMA 4, 4X, 5) X — X X X — — — — — Explosion Proof (NEMA 7, 9) — — — — — — — — — — 7 Molded Case Switch (Automatic) Enclosures (Pages 7-56–7-58) Dimensions (3P Unit Mount) in. (mm) Note: a b c d e f g Height 8 (203) 7.5 (191) Width 4.5 (114) 4.1 (104) 4.5 (114) Depth 4.75 (121) 3.4 (86) 3.93 (100) Pages (Unit Mount)/(I-Line) Pages 7-49/9-24 Pages 7-22, 7-23, 7-28, 7-33, 7-34/9-25 All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. 2P in a 3P module I-Line Q-frame circuit breakers are available 70–225 A only. 250 A Q-frame unit-mount circuit breakers are limited to Cu conductors only. Ungrounded UPS systems only. See page 7-34. Special DC J-Frame only. Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. Requires factory-installed “G” shunt trip and 3P module. Factory-installed option only. 3P only. © 2009 Schneider Electric All Rights Reserved 6.47 (164) Pages 7-24/9-24 7-5 PowerPact® Molded Case Circuit Breakers PowerPact Family Class 611 www.schneider-electric.us The PowerPact Advantage • Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial applications. Flexible: Full range of molded case circuit breakers from 15 A to 3000 A, delivering the ratings, configurations, and operators for your unique applications. Simple: Common catalog numbers, standardized ratings, and a full range of field-installable accessories make product selection, installation and maintenance easier than ever. Common Design Features: Mounting holes, door trim, and handle accessories G-Frame 100 A H-Frame 150 A J-Frame 250 A Table 7.35: D-Frame 600 A P-Frame 1200 A R-Frame 3000 A Interrupting Rating D 240 Vac 25 kA 480 Vac 18 kA 600 Vac 14 kA P-frame K interrupting is 50 kA at 480 and 600 Vac. B 10 kA G 65 kA 35 kA 18 kA J 100 kA 65 kA 25 kA K 65 kA 65 kA a 65 kA a L 125 kA 100 kA 50 kA Rating Termination Poles Voltage Common Catalog Numbering System Frame Table 7.36: M-Frame 800 A PowerPact Interrupting Ratings Voltage a Q-Frame 250 A H G L 3 6 1 5 0 A Suffix Code • Suffix Code • Amperage b • B S A 110 Vac Shunt Trip 2A/2B Auxiliary Switch b Interrupting Rating B D G J K L 240 Vac 10 kA 25 kA 65 kA 100 kA 65 kA 125 kA 480 Vac 600 Vac 18 kA 35 kA 65 kA 65 kA 100 kA 14 kA 18 kA 25 kA 65 kA 50 kA Terminations A I-Line L Lugs on Both Ends F Bus Bar (No Lugs) M Lugs Line Side Only P Lugs Load End Only N Plug-in D Drawout S Rear Connected Studs MINIATURE AND MOLDED CASE CIRCUIT BREAKERS Frame Designation G 100A Frame H 150 A Frame J 250 A Frame Q 250 A Frame D 600 A Frame M 800 A Frame P 1200 A Frame R 3000 A Frame For amperage of M-, P- or R-frame circuit breakers, add a zero to the three amperage digits; for example, 120 = 1200 A. © 2009 Schneider Electric All Rights Reserved 7 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-22 H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23 G- and Q-Frame Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24 D- and M-Frame Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25 P-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26 R-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27 PowerPact® H- and J-Frame Electronic Motor Circuit Protectors . . . . . . 7-28 Mag-Gard® Motor Circuit Protectors (MCP). . . . . . . . . . . . . . . . . . . . . . . 7-30 Automatic Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-33 500 Vdc Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-34 Mission Critical Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-35 PowerPact® Circuit Breaker Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 7-36 Motor Operators and Rotary Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-37 Locks, Installation Accessories, and Rear Connections . . . . . . . . . . . . . 7-38 Mechanical Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-38 Compression Lugs and Power Distribution Connectors (PDC). . . . . . . . 7-40 Terminal Nuts, Terminal Pads, Terminal Shields and Accessories . . . . . 7-41 Plug-In and Drawout Mountings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-42 Micrologic® Electronic Trip Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-43 Micrologic Trip Unit Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-44 7-21 PowerPact® Circuit Breakers H- and J-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT0401 www.schneider-electric.us Table 7.37: Hold H-Frame D Cat. No.bc Trip 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 350 A 350 A 350 A 350 A 400 A 400 A 400 A 400 A 800 A 800 A 800 A 800 A 900 A 900 A 900 A 900 A 750 A 750 A 750 A 750 A 850 A 850 A 850 A 850 A 1450 A 1450 A 1450 A 1450 A 1700 A 1700 A 1700 A 1700 A 7 Adjustable AC Magnetic Trip MINIATURE AND MOLDED CASE CIRCUIT BREAKERS Low G Je Le Terminal Wire Range $ Price 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated H-Frame, 150A 2P, 600 Vac 50/60 Hz, 250 Vdc 15 A 350 A 750 A H( )L26015(C) 870.00 20 A 350 A 750 A H( )L26020(C) 870.00 25 A 350 A 750 A H( )L26025(C) 870.00 30 A 350 A 750 A H( )L26030(C) 870.00 35 A 400 A 850 A H( )L26035(C) 870.00 40 A 400 A 850 A H( )L26040(C) 870.00 45 A 400 A 850 A H( )L26045(C) 870.00 50 A 400 A 850 A H( )L26050(C) 870.00 60 A 800 A 1450 A H( )L26060(C) 870.00 70 A 800 A 1450 A H( )L26070(C) 1062.00 80 A 800 A 1450 A H( )L26080(C) 1062.00 90 A 800 A 1450 A H( )L26090(C) 1062.00 100 A 900 A 1700 A H( )L26100(C) 1062.00 110 A 900 A 1700 A H( )L26110(C) 2072.00 125 A 900 A 1700 A H( )L26125(C) 2072.00 150 A 900 A 1700 A H( )L26150(C) 2072.00 H-Frame 150A 3P, 600 Vac 50/60 Hz, 250 Vdc Current Rating @ 40oC J-Frame Interrupting Rating (2nd Letter of Catalog Number) Fixed AC Magnetic Trip Current Rating @ 40o C HD and HG 2P 2P HJ, HL in 3P module H-Frame 150 A and J-Frame 250 A Thermal-Magnetic UL Current-Limitinge Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unit Suitable for Reverse Connectiona H( )L36015(C) H( )L36020(C) H( )L36025(C) H( )L36030(C) H( )L36035(C) H( )L36040(C) H( )L36045(C) H( )L36050(C) H( )L36060(C) H( )L36070(C) H( )L36080(C) H( )L36090(C) H( )L36100(C) H( )L36110(C) H( )L36125(C) H( )L36150(C) 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1088.00 1328.00 1328.00 1328.00 1328.00 2600.00 2600.00 2600.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1269.00 1497.00 1497.00 1497.00 1497.00 3059.00 3059.00 3059.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1523.00 1797.00 1797.00 1797.00 1797.00 3671.00 3671.00 3671.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1559.00 1721.00 1721.00 1721.00 1721.00 4449.00 4449.00 4449.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 1871.00 2066.00 2066.00 2066.00 2066.00 5339.00 5339.00 5339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1305.00 1493.00 1791.00 1949.00 2339.00 1592.00 1701.00 2042.00 2099.00 2519.00 1592.00 1701.00 2042.00 2099.00 2519.00 1592.00 1701.00 2042.00 2099.00 2519.00 1592.00 1701.00 2042.00 2099.00 2519.00 3120.00 3599.00 4319.00 5174.00 6209.00 3120.00 3599.00 4319.00 5174.00 6209.00 3120.00 3599.00 4319.00 5174.00 6209.00 Interrupting Rating (2nd Letter of Catalog Number) D Cat. No.bc High 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1044.00 1274.00 1274.00 1274.00 1274.00 2486.00 2486.00 2486.00 G Je 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2364.00 2613.00 2613.00 2613.00 2613.00 5534.00 5534.00 5534.00 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 2837.00 3137.00 3137.00 3137.00 3137.00 6641.00 6641.00 6641.00 AL150HD 14–3/0 AWG Al or Cu 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 2849.00 3149.00 3149.00 3149.00 3149.00 6749.00 6749.00 6749.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3419.00 3779.00 3779.00 3779.00 3779.00 8099.00 8099.00 8099.00 AL150HD 14–3/0 AWG Al or Cu Le 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated J-Frame 250A 2P, 600 Vac 50/60 Hz, 250 Vdc 150 A 750 A 1500 A J( )L26150(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 175 A 875 A 1750 A J( )L26175(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 200 A 1000 A 2000 A J( )L26200(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 225 A 1125 A 2250 A J( )L26225(C) 2175.00 2610.00 3212.00 3854.00 4671.00 5606.00 5811.00 250 A 1250 A 2500 A J( )L26250(C) 2988.00 3585.00 4251.00 5102.00 6225.00 7469.00 7194.00 J-Frame 250A 3P, 600 Vac 50/60 Hz, 250 Vdc 150 A 750 A 1500 A J( )L36150(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 175 A 875 A 1750 A J( )L36175(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 200 A 1000 A 2000 A J( )L36200(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 225 A 1125 A 2250 A J( )L36225(C) 2730.00 3276.00 3779.00 4535.00 5432.00 6519.00 7086.00 250 A 1250 A 2500 A J( )L36250(C) 3749.00 4499.00 5001.00 6002.00 7238.00 8685.00 8993.00 a See page 7-23 for circuit breakers with field interchangeable trip units. b To complete catalog number, replace the blank with the appropriate rating (D, G, J, L). c For 100% rated circuit breakers add a “C” in the 9th character place (for example, HDL26015C or JDL26150C). d 100% rated J frame breakers have copper lugs and can only be used with copper wire. e J and L interrupts are UL certified as current limiting. Table 7.38: Terminal Wire Range $ Price 6972.00 AL175JD 6972.00 4–4/0 AWG Al or Cu 6972.00 AL250JD 6972.00 3/0 AWG–350 kcmil Al or Cu 8633.00 8504.00 AL175JD 8504.00 4–4/0 AWG Al or Cu 8504.00 AL250JD 8504.00 3/0 AWG–350 kcmil Al or Cu 10791.00 H- and J-Frame Termination Options Termination Letter For factory-installed A - I-Line (See Section 9) termination, place termination F = No Lugs (includes terminal nut kit on both ends)f letter in the third block of the L = Lugs both ends circuit breaker catalog number. M = Lugs ON end Terminal Nut Kit OFF end HGL36100 P = Lugs OFF end Terminal Nut Kit ON end N = Plug-in g Termination Letter D = Drawout g Plug-in Drawout Rear Connected S = Rear Connected g f Add TS suffix for circuit breaker without terminal nut kit. g For N and D pricing, add termination pricing on page 7-42 to price. For S pricing, add termination pricing on page 7-38 to price. Table 7.39: Voltage 240 Vac 480 Vac 600 Vac 7-22 H- and J-Frame Interrupting Ratings Interrupting Rating D 25 kA 18 kA 14 kA G 65 kA 35 kA 18 kA J 100 kA 65 kA 25 kA DE2 L 125 kA 100 kA 50 kA Discount Schedule Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-36 Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-39 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-55 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56 © 2009 Schneider Electric All Rights Reserved PowerPact® Circuit Breaker Accessories Electrical Accessories Class 612 / Refer to Catalog 0612CT0101 www.schneider-electric.us Table 7.77: Electrical Accessories G-Frame H-, J-, and D-Frame H- and J-Frame Accessory Description Auxiliary and Alarm Switches (OF, SD, SDE) H-, J-, D-, M-, P, and R-Frame G-Frame Provides circuit breaker contact status. Standard Min Load = 10mA with 24V Note: The location of the accessory in the circuit breaker determines its function. Low Level Min Load = 1mA with 24V Shunt Trip (MX) Trips the circuit breaker from a remote location by means of a trip coil energized from a separate supply voltage circuit. 7 H-, J-, and D-Frame G-Frame MINIATURE AND MOLDED CASE CIRCUIT BREAKERS Undervoltage Trip H-, J-, and D-Frame Time Delay Unit a b c d 7-36 G-Frame Instantaneously opens the circuit breaker when the under-voltage trip supply voltage drops to a value between 35% and 70% of its rated voltage. Closing is allowed when the supply voltage of the undervoltage trip reaches 85% of rated voltage. Undervoltage trip with externally mounted adjustable time delay unit for UVR of 0.5, 0.9, 1.5, 3.0 seconds before circuit breaker trips Rated Voltage FieldFactoryFieldInstallable $ Price Installed Cat. No. Cat. Suffix Installable $ Price Cat. No. AAC 297.00 AA S29450 297.00 — — AB 2x S29450 594.00 — — AC AAC 297.00 BC S29450 297.00 1 auxiliary switch (OF) 1a1b 2 auxiliary switch (OF) 2a2b 3 auxiliary switch (OF) 3a3b Alarm Switch (SD) 1a1b Overcurrent trip switch (SDE) 1a1b OF Switch Consisting of: SDE Adapter Alarm switch and Overcurrent trip switch OF Switch Consisting of: SDE Adapter Auxiliary Switch/Alarm Switch/Adapter (OF/SD/SDE) Kit One auxiliary switch (OF) 1a1b Two auxiliary switches (OF) 2a2b 3 auxiliary switches (OF) 3a3b Alarm Switch (SD) 1a1b Overcurrent trip switch (SDE) 1a1b OF Switch Consisting of: SDE Adapter Alarm switch and Overcurrent trip switch OF Switch Consisting of: SDE Adapterd 24 48 120 110/130 208 240 AC 200/250 277 208/277 480 380/480 525/600 12 24 30 DC 48 60 125 250 24 48 120 110/130 208 240 AC 200/250 277 208/277 480 380/480 525/600 12 24 30 DC 48 60 125 250 — — BD — — — — — — — — BE — — — — — — — — — — — — — — — — — AE AF AG BH — — BJ — — — — — — — — BK — — — — GSA — GSB GSC — GSD — GSH — — — GSO — GSP — GSR GSS — — GUA — GUB GUC — GUD — GUH — — — GUO — GUP — GUR GUS — — — — SK SL — SA — — — — SD — SH SJ SN SO SU SP SV SR SS UK UL — UA — — — — UD — UH UJ UN UO UU UP UV UR US 717.00 717.00 717.00 717.00 — 338.00 S29450 297.00 S29451 40.50 — FieldInstallable Cat. No. S29450 2x S29450 3x S29450 S29450 Factory FieldInstalled Installable $ Price $ Price Cat. Suffix Cat. No. 297.00 594.00 891.00 297.00 AA AB AC BC S29450 2x S29450 3x S29450 S29450 297.00 594.00 891.00 297.00 S29450 297.00 BD S29450 297.00 — — — — — — — — — — 635.00 2x S29450 594.00 2x S29450 594.00 S29451 40.50 — M-, P-, and R-Frame D-Frame — — — — — — — S29452 372.00 S29452 372.00 2x S29452 744.00 2x S29452 744.00 — — 3x S29452 1116.00 S29452 372.00 S29452 372.00 — 413.00 S29452 372.00 S29451 40.50 — — — — — 785.00 2x S29452 744.00 2x S29452 744.00 S29451 40.50 S29384 S29385 — S29386 — — 717.00 — — S29387 S29388 S29389 S29382 S29390 S29391 S29392 717.00 S29383 S29393 S29394 S29404 S29405 S29406 — S29452 372.00 717.00 S29407 S29408 S29409 S29402 S29410 S29411 S29412 717.00 S29403 S29413 S29414 — — S29384 S29385 — S29386 — — — — S29387 — S29388 S29389 S29382 S29390 S29391 S29392 S29383 S29393 S29394 S29404 S29405 — S29406 — — — — S29407 — S29408 S29409 S29402 S29410 S29411 S29412 S29403 S29413 S29414 — — 717.00 717.00 717.00 717.00 BE — — S29452 372.00 2x S29452 744.00 3x S29452 1116.00 S29452 372.00 BJ S29452 372.00 — — — — — — BK — — SK SL — SA — — SC — SD — SH — SN SK SK SL SL SA SC UK UL — UA — — UC — — — UH — — UK UK UL UL UA UC — — — — — — FL — — — — — — — FA 200/250 — — — — — — — FC 380/480 — — — — — — — FH — — — — — — — KA — — — — — — — KC AC/DC Discount Schedule — — S33801c 297.00 — DE2F 594.00 — 48/60 DE2 — — AE AF AG BH 100/130 Undervoltage trip with 100/130 externally mounted non-adjustable time AC/DC delay unit of 0.25 sec 200/250 before circuit breaker trips. Field-installable kit includes time delay module only. Order undervoltage trip separately. Discount schedule DE2F. P-frame drawout circuit breaker only. SDE Adapter used for H- and J-frame only. 2x S29450 2x S29452 744.00 — — — — S33659 S33660 — S33661 — — 755.00 S33662 — S33663 — S33664 — S33658 S33659 S33659 S33660 755.00 S33660 S33661 S33662 S33668 S33669 — S33670 — — 755.00 S33671 — — — S33673 — — S33668 S33668 S33669 755.00 S33669 S33670 S33671 S33680a b S33681a b 1140.00 S33682a b S33683a b S33684a b 930.00 S33685a b © 2009 Schneider Electric All Rights Reserved Dimensions and Shipping Weights Molded Case Circuit Breakers www.schneider-electric.us F A Table 7.143: E Circuit Breaker No. of Cat. No. Poles Fig. No. A Prefix 2 25 6.40 HD, HG, HJ, HL 3 26 6.40 JD, JG, JJ, JL 3 27 7.52 DG, DJ, DL 3 28 13.38 F A D E C Figure 25 Table 7.144: Figure 26 B G D F A Circuit Breaker Cat. No. Prefix MG, MJ (800 A and below) PG, PJ, PK, PL (1000–1200 A) RG, RJ, RL E Figure 27 G A Table 7.146: F B D Figure 28 E B E E B A A A Figure 29 Figure 30 Figure 31 B Dimensions — Inches B C D E F G 2.74 4.12 4.12 5.51 2.87 2.87 2.87 3.75 4.36 4.36 5.00 6.61 0.74 0.74 1.30 2.22 4.92 4.92 4.92 8.93 — 1.38 1.38 1.77 ED, EG, EG and GJL Circuit Breakers Dimensions — Inches No. of Poles Fig. No. 1 2 3 3 29 30 31 32 A B C D E 0.98 1.96 2.94 3.54 5.66 5.66 5.66 4.72 3.09 3.09 3.09 2.76 4.05 4.05 4.05 3.94 3.32 3.32 3.32 2.20 MG, MJ, PG, PJ, PL, RG, RJ and RL Circuit Breakers Dimensions — Inches No. of Poles Fig. No. A B C D E F G 2, 3 33 12.86 8.27 5.77 8.05 2.49 7.87 7.83 2, 3 33 16.16 8.27 5.77 8.05 4.19 7.87 7.83 2, 3 34 16.24 16.54 6.63 14.49 8.73 14.25 15.35 Shipping Weightsa Approx. Shipping Frame Size Weight (Lbs.) HD, HG, HJ, HL 2P 4 DG, DJ, DL HD, HG, HJ, HL 3P 5 GJ JD, JG, JJ, JL 5 MG, MJ ED, EG, EJ 1P 2 PG, PJ, PL ED, EG, EJ 2P 3 RG, RJ, RL (Without RLTB) ED, EG, EJ 3P 4 a All weights are for 3P circuit breakers unless otherwise noted. Frame Size Approx. Shipping Weight (Lbs.) 14 3 34 32 52 B C D B G E Circuit Breaker Cat. No. Prefix ED, EG, EJ ED, EG, EJ ED, EG, EJ GJ Table 7.145: C C HD, HG, HJ, HL, JD, JG, JJ, JL, DG, DJ, and DL Circuit Breakers MINIATURE AND MOLDED CASE CIRCUIT BREAKERS B G B D C E A C AF D Figure 32 7 E Figure 33 B G F D C AE Figure 34 © 2009 Schneider Electric All Rights Reserved 7-55
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Modify Date : 2011:08:27 09:52:17+05:30 Create Date : 2011:08:27 09:47:27+05:30 Creator : Adobe InDesign CS3 (5.0) Producer : Adobe PDF Library 8.0 Page Count : 5EXIF Metadata provided by EXIF.tools