Selection Information

Molded Case Circuit Breakers
Class 500, 600, 800

www.schneider-electric.us

100 A F-Frame

Circuit Breaker Type
Number of Poles
Current Range

PowerPact 250 A J-Frame

PowerPact 250 A Q-Frame

FI

FY

JD

JG

JJ

JL

QB

QD

QG

QJ

2, 3

1

2,3a

2,3a

2,3a

2,3a

2, 3

2, 3

2, 3

2, 3

20–100

15–30

150–250 A

150–250 A

150–250 A

150–250 A

70–250b

70–250b

70–250b

70–250b
100

Interrupting Ratings

UL/CSA/NOM
Rating
(kA RMS)
(50/60 Hz)

240 Vac

200

14

25

65

100

125

10

25

65

480Y/277 Vac

200

14

18

35

65

100

—

—

—

—

480 Vac

200

—

18

35

65

100

—

—

—

—

600Y/347 Vac

100

—

14

18

25

50

—

—

—

—

600 Vac

100

—

14

18

25

50

—

—

—

—

250 Vdc

—

—

20

20

20

20

—

—

—

—

500 Vdcc

—

—

—

20

—

—

—

—

—

—

240 Vac

—

—

25/25

65/65

100/100

125/125

10/5

10/5

10/5

10/5

18/18

35/35

65/65

100/100

10/5

10/5

10/5

10/5

DC Ratings
IEC Rating
(kA RMS)
Icu/lcsd

415 Vac

IEC 50/60 Hz

6/1.5
—
For additional IEC ratings, see
the Supplemental Digest.

Special Ratings
Fed. Specs W-C-375B/GEN

X

—

X

X

X

X

X

X

X

X

HACR (2P, 3P)

—

—

X

X

X

X

X

X

X

—

Unit Mount

X

—

X

X

X

X

X

X

X

X

I-Line®

X

X

X

X

X

X

X

X

X

X

Rear Connection

—

—

X

X

X

X

—

—

—

—

Drawout

—

—

X

X

X

X

—

—

—

—

Optional Lugs

X

—

X

X

X

X

—

—

—

—

Connections/Terminations

Shunt Trip

Xf

—

X

X

X

X

—

—

—

—

Undervoltage Trip

Xf

—

X

X

X

X

—

—

—

—

Auxiliary Switches

Xf

—

X

X

X

X

—

—

—

—

Alarm Switch

Xf

—

X

X

X

X

—

—

—

—

Motor Operator

X

—

X

X

X

X

—

—

—

—

Handle Operators

—

—

X

X

X

X

—

—

—

—

Mechanical Interlocks (3P)

—

—

X

X

X

X

X

X

X

X

Handle Padlock Attachment

X

X

X

X

X

X

X

X

X

X

Cylinder Lock (3Pf)

—

—

—

—

—

—

—

—

—

—

Optional GF Protectione

X

—

—

—

—

—

—

—

—

—

MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS

Accessories and Modifications

Trip System Type
Thermal-magnetic

X

X

X

X

X

X

X

X

X

X

Instantaneous-only (MCP)

—

—

—

Xg

Xg

—

—

—

—

—

—

—

X

X

X

X

X

—

—

—

Electronic

—

—

—

—

—

—

—

—

—

—

General Purpose (NEMA 1)

X

—

X

X

X

—

X

X

X

X

Raintight (NEMA 3R)

X

—

X

X

X

—

X

X

X

X

Dust-tight (NEMA 12)

X

—

X

X

X

—

—

—

—

—

Watertight (NEMA 4, 4X, 5)

X

—

X

X

X

—

—

—

—

—

Explosion Proof (NEMA 7, 9)

—

—

—

—

—

—

—

—

—

—

7

Molded Case Switch (Automatic)
Enclosures (Pages 7-56–7-58)

Dimensions
(3P Unit Mount)
in. (mm)

Note:
a
b
c
d
e
f
g

Height

8 (203)

7.5 (191)

Width

4.5 (114)

4.1 (104)

4.5 (114)

Depth

4.75 (121)

3.4 (86)

3.93 (100)

Pages (Unit Mount)/(I-Line)
Pages 7-49/9-24
Pages 7-22, 7-23, 7-28, 7-33, 7-34/9-25
All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
2P in a 3P module
I-Line Q-frame circuit breakers are available 70–225 A only. 250 A Q-frame unit-mount circuit breakers are limited to Cu conductors only.
Ungrounded UPS systems only. See page 7-34. Special DC J-Frame only.
Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest.
Requires factory-installed “G” shunt trip and 3P module.
Factory-installed option only.
3P only.

© 2009 Schneider Electric
All Rights Reserved

6.47 (164)

Pages 7-24/9-24

7-5

PowerPact® Molded Case
Circuit Breakers

PowerPact Family
Class 611

www.schneider-electric.us

The PowerPact Advantage
• Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial
applications.
Flexible: Full range of molded case circuit breakers from 15 A to 3000 A, delivering the ratings, configurations, and operators for
your unique applications.
Simple: Common catalog numbers, standardized ratings, and a full range of field-installable accessories make product selection,
installation and maintenance easier than ever.
Common Design Features: Mounting holes, door trim, and handle accessories

G-Frame
100 A

H-Frame
150 A

J-Frame
250 A

Table 7.35:

D-Frame
600 A

P-Frame
1200 A

R-Frame
3000 A

Interrupting Rating

D
240 Vac
25 kA
480 Vac
18 kA
600 Vac
14 kA
P-frame K interrupting is 50 kA at 480 and 600 Vac.

B
10 kA

G
65 kA
35 kA
18 kA

J
100 kA
65 kA
25 kA

K
65 kA
65 kA a
65 kA a

L
125 kA
100 kA
50 kA

Rating

Termination

Poles

Voltage

Common Catalog Numbering System

Frame

Table 7.36:

M-Frame
800 A

PowerPact Interrupting Ratings

Voltage

a

Q-Frame
250 A

H

G

L

3

6

1

5

0

A

Suffix
Code

•

Suffix
Code

•

Amperage
b

•

B

S

A
110 Vac Shunt Trip
2A/2B Auxiliary Switch

b

Interrupting Rating

B
D
G
J
K
L

240
Vac
10 kA
25 kA
65 kA
100 kA
65 kA
125 kA

480
Vac

600
Vac

18 kA
35 kA
65 kA
65 kA
100 kA

14 kA
18 kA
25 kA
65 kA
50 kA

Terminations
A I-Line
L Lugs on Both Ends
F Bus Bar (No Lugs)
M Lugs Line Side Only
P Lugs Load End Only
N Plug-in
D Drawout
S Rear Connected Studs

MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS

Frame Designation
G 100A Frame
H 150 A Frame
J 250 A Frame
Q 250 A Frame
D 600 A Frame
M 800 A Frame
P 1200 A Frame
R 3000 A Frame

For amperage of M-, P- or R-frame circuit breakers, add a zero to the three amperage digits; for example, 120 = 1200 A.

© 2009 Schneider Electric
All Rights Reserved

7

Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page
H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-22
H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23
G- and Q-Frame Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24
D- and M-Frame Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25
P-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26
R-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27
PowerPact® H- and J-Frame Electronic Motor Circuit Protectors . . . . . . 7-28
Mag-Gard® Motor Circuit Protectors (MCP). . . . . . . . . . . . . . . . . . . . . . . 7-30
Automatic Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-33
500 Vdc Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-34
Mission Critical Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-35
PowerPact® Circuit Breaker Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 7-36
Motor Operators and Rotary Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-37
Locks, Installation Accessories, and Rear Connections . . . . . . . . . . . . . 7-38
Mechanical Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-38
Compression Lugs and Power Distribution Connectors (PDC). . . . . . . . 7-40
Terminal Nuts, Terminal Pads, Terminal Shields and Accessories . . . . . 7-41
Plug-In and Drawout Mountings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-42
Micrologic® Electronic Trip Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-43
Micrologic Trip Unit Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-44

7-21

PowerPact® Circuit
Breakers

H- and J-Frame Circuit Breakers
Class 611 / Refer to Catalog 0611CT0401
www.schneider-electric.us

Table 7.37:

Hold

H-Frame

D

Cat. No.bc

Trip

15 A
20 A
25 A
30 A
35 A
40 A
45 A
50 A
60 A
70 A
80 A
90 A
100 A
110 A
125 A
150 A

350 A
350 A
350 A
350 A
400 A
400 A
400 A
400 A
800 A
800 A
800 A
800 A
900 A
900 A
900 A
900 A

750 A
750 A
750 A
750 A
850 A
850 A
850 A
850 A
1450 A
1450 A
1450 A
1450 A
1700 A
1700 A
1700 A
1700 A

7

Adjustable AC
Magnetic
Trip

MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS

Low

G

Je

Le
Terminal
Wire Range

$ Price
80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated

H-Frame, 150A 2P, 600 Vac 50/60 Hz, 250 Vdc
15 A
350 A 750 A H( )L26015(C)
870.00
20 A
350 A 750 A H( )L26020(C)
870.00
25 A
350 A 750 A H( )L26025(C)
870.00
30 A
350 A 750 A H( )L26030(C)
870.00
35 A
400 A 850 A H( )L26035(C)
870.00
40 A
400 A 850 A H( )L26040(C)
870.00
45 A
400 A 850 A H( )L26045(C)
870.00
50 A
400 A 850 A H( )L26050(C)
870.00
60 A
800 A 1450 A H( )L26060(C)
870.00
70 A
800 A 1450 A H( )L26070(C)
1062.00
80 A
800 A 1450 A H( )L26080(C)
1062.00
90 A
800 A 1450 A H( )L26090(C)
1062.00
100 A 900 A 1700 A H( )L26100(C)
1062.00
110 A 900 A 1700 A H( )L26110(C)
2072.00
125 A 900 A 1700 A H( )L26125(C)
2072.00
150 A 900 A 1700 A H( )L26150(C)
2072.00
H-Frame 150A 3P, 600 Vac 50/60 Hz, 250 Vdc

Current
Rating @
40oC

J-Frame

Interrupting Rating (2nd Letter of Catalog Number)

Fixed AC
Magnetic
Trip

Current
Rating @
40o C

HD and HG 2P
2P HJ, HL in 3P module

H-Frame 150 A and J-Frame 250 A Thermal-Magnetic UL Current-Limitinge Circuit Breakers
(600 Vac, 250 Vdc) With Factory Sealed Trip Unit Suitable for Reverse Connectiona

H( )L36015(C)
H( )L36020(C)
H( )L36025(C)
H( )L36030(C)
H( )L36035(C)
H( )L36040(C)
H( )L36045(C)
H( )L36050(C)
H( )L36060(C)
H( )L36070(C)
H( )L36080(C)
H( )L36090(C)
H( )L36100(C)
H( )L36110(C)
H( )L36125(C)
H( )L36150(C)

1088.00
1088.00
1088.00
1088.00
1088.00
1088.00
1088.00
1088.00
1088.00
1328.00
1328.00
1328.00
1328.00
2600.00
2600.00
2600.00

1269.00
1269.00
1269.00
1269.00
1269.00
1269.00
1269.00
1269.00
1269.00
1497.00
1497.00
1497.00
1497.00
3059.00
3059.00
3059.00

1523.00
1523.00
1523.00
1523.00
1523.00
1523.00
1523.00
1523.00
1523.00
1797.00
1797.00
1797.00
1797.00
3671.00
3671.00
3671.00

1559.00
1559.00
1559.00
1559.00
1559.00
1559.00
1559.00
1559.00
1559.00
1721.00
1721.00
1721.00
1721.00
4449.00
4449.00
4449.00

1871.00
1871.00
1871.00
1871.00
1871.00
1871.00
1871.00
1871.00
1871.00
2066.00
2066.00
2066.00
2066.00
5339.00
5339.00
5339.00

1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1305.00
1493.00
1791.00
1949.00
2339.00
1592.00
1701.00
2042.00
2099.00
2519.00
1592.00
1701.00
2042.00
2099.00
2519.00
1592.00
1701.00
2042.00
2099.00
2519.00
1592.00
1701.00
2042.00
2099.00
2519.00
3120.00
3599.00
4319.00
5174.00
6209.00
3120.00
3599.00
4319.00
5174.00
6209.00
3120.00
3599.00
4319.00
5174.00
6209.00
Interrupting Rating (2nd Letter of Catalog Number)
D

Cat. No.bc

High

1044.00
1044.00
1044.00
1044.00
1044.00
1044.00
1044.00
1044.00
1044.00
1274.00
1274.00
1274.00
1274.00
2486.00
2486.00
2486.00

G

Je

2364.00
2364.00
2364.00
2364.00
2364.00
2364.00
2364.00
2364.00
2364.00
2613.00
2613.00
2613.00
2613.00
5534.00
5534.00
5534.00

2837.00
2837.00
2837.00
2837.00
2837.00
2837.00
2837.00
2837.00
2837.00
3137.00
3137.00
3137.00
3137.00
6641.00
6641.00
6641.00

AL150HD
14–3/0 AWG
Al or Cu

2849.00
2849.00
2849.00
2849.00
2849.00
2849.00
2849.00
2849.00
2849.00
3149.00
3149.00
3149.00
3149.00
6749.00
6749.00
6749.00

3419.00
3419.00
3419.00
3419.00
3419.00
3419.00
3419.00
3419.00
3419.00
3779.00
3779.00
3779.00
3779.00
8099.00
8099.00
8099.00

AL150HD
14–3/0 AWG
Al or Cu

Le

80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated

J-Frame 250A 2P, 600 Vac 50/60 Hz, 250 Vdc
150 A 750 A 1500 A J( )L26150(C)
2175.00
2610.00
3212.00
3854.00
4671.00
5606.00
5811.00
175 A 875 A 1750 A J( )L26175(C)
2175.00
2610.00
3212.00
3854.00
4671.00
5606.00
5811.00
200 A 1000 A 2000 A J( )L26200(C)
2175.00
2610.00
3212.00
3854.00
4671.00
5606.00
5811.00
225 A 1125 A 2250 A J( )L26225(C)
2175.00
2610.00
3212.00
3854.00
4671.00
5606.00
5811.00
250 A 1250 A 2500 A J( )L26250(C)
2988.00
3585.00
4251.00
5102.00
6225.00
7469.00
7194.00
J-Frame 250A 3P, 600 Vac 50/60 Hz, 250 Vdc
150 A 750 A 1500 A J( )L36150(C)
2730.00
3276.00
3779.00
4535.00
5432.00
6519.00
7086.00
175 A 875 A 1750 A J( )L36175(C)
2730.00
3276.00
3779.00
4535.00
5432.00
6519.00
7086.00
200 A 1000 A 2000 A J( )L36200(C)
2730.00
3276.00
3779.00
4535.00
5432.00
6519.00
7086.00
225 A 1125 A 2250 A J( )L36225(C)
2730.00
3276.00
3779.00
4535.00
5432.00
6519.00
7086.00
250 A 1250 A 2500 A J( )L36250(C)
3749.00
4499.00
5001.00
6002.00
7238.00
8685.00
8993.00
a
See page 7-23 for circuit breakers with field interchangeable trip units.
b
To complete catalog number, replace the blank with the appropriate rating (D, G, J, L).
c
For 100% rated circuit breakers add a “C” in the 9th character place (for example, HDL26015C or JDL26150C).
d
100% rated J frame breakers have copper lugs and can only be used with copper wire.
e
J and L interrupts are UL certified as current limiting.

Table 7.38:

Terminal
Wire Range

$ Price

6972.00
AL175JD
6972.00 4–4/0 AWG Al or Cu
6972.00
AL250JD
6972.00 3/0 AWG–350 kcmil
Al or Cu
8633.00
8504.00
AL175JD
8504.00 4–4/0 AWG Al or Cu
8504.00
AL250JD
8504.00 3/0 AWG–350 kcmil
Al or Cu
10791.00

H- and J-Frame Termination Options

Termination Letter
For factory-installed
A - I-Line (See Section 9)
termination, place termination
F = No Lugs (includes terminal nut kit on both ends)f letter in the third block of the
L = Lugs both ends
circuit breaker catalog number.
M = Lugs ON end Terminal Nut Kit OFF end
HGL36100
P = Lugs OFF end Terminal Nut Kit ON end
N = Plug-in g
Termination Letter
D = Drawout g
Plug-in
Drawout
Rear Connected
S = Rear Connected g
f
Add TS suffix for circuit breaker without terminal nut kit.
g
For N and D pricing, add termination pricing on page 7-42 to price. For S pricing, add termination pricing on page 7-38 to price.

Table 7.39:
Voltage
240 Vac
480 Vac
600 Vac

7-22

H- and J-Frame Interrupting Ratings
Interrupting Rating
D
25 kA
18 kA
14 kA

G
65 kA
35 kA
18 kA

J
100 kA
65 kA
25 kA

DE2

L
125 kA
100 kA
50 kA
Discount
Schedule

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-36
Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-39
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-55
Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-56

© 2009 Schneider Electric
All Rights Reserved

PowerPact® Circuit
Breaker Accessories

Electrical Accessories
Class 612 / Refer to Catalog 0612CT0101
www.schneider-electric.us

Table 7.77:

Electrical Accessories
G-Frame

H-, J-, and D-Frame
H- and J-Frame

Accessory

Description

Auxiliary and Alarm Switches
(OF, SD, SDE)

H-, J-, D-, M-, P,
and R-Frame

G-Frame

Provides
circuit
breaker
contact
status.

Standard
Min
Load =
10mA with
24V

Note: The
location of
the
accessory
in the circuit
breaker
determines
its function. Low Level
Min
Load =
1mA with
24V

Shunt Trip (MX)

Trips the circuit
breaker from a remote
location by means of a
trip coil energized from
a separate supply
voltage circuit.

7

H-, J-, and
D-Frame

G-Frame

MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS

Undervoltage Trip

H-, J-, and
D-Frame

Time Delay Unit

a
b
c
d

7-36

G-Frame

Instantaneously
opens the circuit
breaker when the
under-voltage trip
supply voltage drops
to a value between
35% and 70% of its
rated voltage. Closing
is allowed when the
supply voltage of the
undervoltage trip
reaches 85% of rated
voltage.

Undervoltage trip with
externally mounted
adjustable time delay
unit for UVR of 0.5,
0.9, 1.5, 3.0 seconds
before circuit breaker
trips

Rated Voltage

FieldFactoryFieldInstallable $ Price Installed
Cat. No.
Cat. Suffix Installable $ Price
Cat. No.
AAC
297.00
AA
S29450 297.00
—
—
AB
2x S29450 594.00
—
—
AC
AAC
297.00
BC
S29450 297.00

1 auxiliary switch (OF) 1a1b
2 auxiliary switch (OF) 2a2b
3 auxiliary switch (OF) 3a3b
Alarm Switch (SD) 1a1b
Overcurrent trip switch (SDE)
1a1b
OF Switch
Consisting of:
SDE Adapter
Alarm switch and Overcurrent trip
switch
OF Switch
Consisting of:
SDE Adapter
Auxiliary Switch/Alarm
Switch/Adapter (OF/SD/SDE) Kit
One auxiliary switch (OF) 1a1b
Two auxiliary switches (OF) 2a2b
3 auxiliary switches (OF) 3a3b
Alarm Switch (SD) 1a1b
Overcurrent trip switch (SDE)
1a1b
OF Switch
Consisting of:
SDE Adapter
Alarm switch and Overcurrent trip
switch
OF Switch
Consisting of:
SDE Adapterd
24
48
120
110/130
208
240
AC
200/250
277
208/277
480
380/480
525/600
12
24
30
DC
48
60
125
250
24
48
120
110/130
208
240
AC
200/250
277
208/277
480
380/480
525/600
12
24
30
DC
48
60
125
250

—

—

BD

—
—

—
—

—
—

—

—

BE

—
—

—
—

—
—

—

—

—

—
—
—
—

—
—
—
—

AE
AF
AG
BH

—

—

BJ

—
—

—
—

—
—

—

—

BK

—
—
—
—
GSA
—
GSB
GSC
—
GSD
—
GSH
—
—
—
GSO
—
GSP
—
GSR
GSS
—
—
GUA
—
GUB
GUC
—
GUD
—
GUH
—
—
—
GUO
—
GUP
—
GUR
GUS

—
—

—
—
SK
SL
—
SA
—
—
—
—
SD
—
SH
SJ
SN
SO
SU
SP
SV
SR
SS
UK
UL
—
UA
—
—
—
—
UD
—
UH
UJ
UN
UO
UU
UP
UV
UR
US

717.00

717.00

717.00

717.00

—

338.00

S29450 297.00
S29451 40.50
—

FieldInstallable
Cat. No.
S29450
2x S29450
3x S29450
S29450

Factory
FieldInstalled Installable $ Price
$ Price Cat. Suffix Cat. No.
297.00
594.00
891.00
297.00

AA
AB
AC
BC

S29450
2x S29450
3x S29450
S29450

297.00
594.00
891.00
297.00

S29450 297.00

BD

S29450

297.00

—
—

—
—

—
—

—
—

—
—

635.00 2x S29450 594.00

2x S29450 594.00
S29451 40.50
—

M-, P-, and R-Frame
D-Frame

—

—
—

—
—

—

—

S29452 372.00
S29452 372.00
2x S29452 744.00 2x S29452 744.00
—
— 3x S29452 1116.00
S29452 372.00
S29452 372.00
—

413.00

S29452 372.00
S29451 40.50
—

—
—

—
—

785.00 2x S29452 744.00

2x S29452 744.00
S29451 40.50
S29384
S29385
—
S29386
—
—
717.00
—
—
S29387
S29388
S29389
S29382
S29390
S29391
S29392 717.00
S29383
S29393
S29394
S29404
S29405
S29406

—

S29452 372.00

717.00

S29407
S29408
S29409
S29402
S29410
S29411
S29412 717.00
S29403
S29413
S29414

—
—
S29384
S29385
—
S29386
—
—
—
—
S29387
—
S29388
S29389
S29382
S29390
S29391
S29392
S29383
S29393
S29394
S29404
S29405
—
S29406
—
—
—
—
S29407
—
S29408
S29409
S29402
S29410
S29411
S29412
S29403
S29413
S29414

—
—

717.00

717.00

717.00

717.00

BE
—
—

S29452 372.00
2x S29452 744.00
3x S29452 1116.00
S29452 372.00

BJ

S29452

372.00

—
—

—
—

—
—

BK
—
—
SK
SL
—
SA
—
—
SC
—
SD
—
SH
—
SN
SK
SK
SL
SL
SA
SC
UK
UL
—
UA
—
—
UC
—
—
—
UH
—
—
UK
UK
UL
UL
UA
UC

—

—

—

—

—

—

FL

—

—

—

—

—

—

—

FA

200/250

—

—

—

—

—

—

—

FC

380/480

—

—

—

—

—

—

—

FH

—

—

—

—

—

—

—

KA

—

—

—

—

—

—

—

KC

AC/DC

Discount
Schedule

—
—

S33801c 297.00

—

DE2F

594.00

—

48/60

DE2

—
—

AE
AF
AG
BH

100/130

Undervoltage trip with
100/130
externally mounted
non-adjustable time
AC/DC
delay unit of 0.25 sec
200/250
before circuit breaker
trips.
Field-installable kit includes time delay module only. Order undervoltage trip separately.
Discount schedule DE2F.
P-frame drawout circuit breaker only.
SDE Adapter used for H- and J-frame only.

2x S29450

2x S29452

744.00

—
—
—
—
S33659
S33660
—
S33661
—
—
755.00
S33662
—
S33663
—
S33664
—
S33658
S33659
S33659
S33660 755.00
S33660
S33661
S33662
S33668
S33669
—
S33670
—
—
755.00
S33671
—
—
—
S33673
—
—
S33668
S33668
S33669 755.00
S33669
S33670
S33671
S33680a
b
S33681a
b
1140.00
S33682a
b
S33683a
b
S33684a
b
930.00
S33685a
b

© 2009 Schneider Electric
All Rights Reserved

Dimensions and Shipping Weights
Molded Case Circuit Breakers
www.schneider-electric.us

F

A

Table 7.143:

E

Circuit Breaker No. of
Cat. No.
Poles Fig. No.
A
Prefix
2
25
6.40
HD, HG, HJ, HL
3
26
6.40
JD, JG, JJ, JL
3
27
7.52
DG, DJ, DL
3
28
13.38

F

A

D

E

C

Figure 25

Table 7.144:

Figure 26
B

G

D
F

A

Circuit Breaker
Cat. No.
Prefix
MG, MJ
(800 A and below)
PG, PJ, PK, PL
(1000–1200 A)
RG, RJ, RL

E

Figure 27
G

A

Table 7.146:
F

B

D

Figure 28

E

B

E

E

B

A

A

A

Figure 29

Figure 30

Figure 31

B

Dimensions — Inches
B

C

D

E

F

G

2.74
4.12
4.12
5.51

2.87
2.87
2.87
3.75

4.36
4.36
5.00
6.61

0.74
0.74
1.30
2.22

4.92
4.92
4.92
8.93

—
1.38
1.38
1.77

ED, EG, EG and GJL Circuit Breakers
Dimensions — Inches

No. of
Poles

Fig. No.

1
2
3
3

29
30
31
32

A

B

C

D

E

0.98
1.96
2.94
3.54

5.66
5.66
5.66
4.72

3.09
3.09
3.09
2.76

4.05
4.05
4.05
3.94

3.32
3.32
3.32
2.20

MG, MJ, PG, PJ, PL, RG, RJ and RL Circuit Breakers
Dimensions — Inches

No. of
Poles

Fig.
No.

A

B

C

D

E

F

G

2, 3

33

12.86

8.27

5.77

8.05

2.49

7.87

7.83

2, 3

33

16.16

8.27

5.77

8.05

4.19

7.87

7.83

2, 3

34

16.24

16.54

6.63

14.49

8.73

14.25

15.35

Shipping Weightsa

Approx. Shipping
Frame Size
Weight (Lbs.)
HD, HG, HJ, HL 2P
4
DG, DJ, DL
HD, HG, HJ, HL 3P
5
GJ
JD, JG, JJ, JL
5
MG, MJ
ED, EG, EJ 1P
2
PG, PJ, PL
ED, EG, EJ 2P
3
RG, RJ, RL (Without RLTB)
ED, EG, EJ 3P
4
a
All weights are for 3P circuit breakers unless otherwise noted.
Frame Size

Approx. Shipping
Weight (Lbs.)
14
3
34
32
52

B

C
D

B
G
E

Circuit Breaker
Cat. No.
Prefix
ED, EG, EJ
ED, EG, EJ
ED, EG, EJ
GJ

Table 7.145:

C

C

HD, HG, HJ, HL, JD, JG, JJ, JL, DG, DJ, and DL
Circuit Breakers

MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS

B
G

B

D
C

E

A

C

AF

D

Figure 32

7

E

Figure 33
B
G
F

D
C

AE

Figure 34

© 2009 Schneider Electric
All Rights Reserved

7-55



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Modify Date                     : 2011:08:27 09:52:17+05:30
Create Date                     : 2011:08:27 09:47:27+05:30
Creator                         : Adobe InDesign CS3 (5.0)
Producer                        : Adobe PDF Library 8.0
Page Count                      : 5
EXIF Metadata provided by EXIF.tools

Navigation menu