Power supply CP-D 12/0.83

2CDC 271 024 F0t07

Primary switch mode power supply
Data sheet
Features
�
�
�
�
�

a  OUTPUT +, ‑:
terminals ‑ output
b  INPUT L, N:
terminals ‑ input
c  DC ON: green LED ‑
output voltage applied
d  DC LOW: red LED ‑
output voltage too low
















Rated output voltage 12 V DC
Rated output current 0.83 A
Rated output power 10 W
Wide range input 100‑240 V AC (90‑264 V AC, 120‑375 V DC)
Efficiency of typ. 78 %
Low power dissipation and low heating
Free convection cooling (no forced cooling with ventilators)
Ambient temperature range during operation ‑40...+70 °C
Open‑circuit, overload and short‑circuit stable
Integrated input fuse
U/I characteristic (fold‑forward behaviour at overload ‑ no switch‑off)
LEDs for status indication
Structural form ideal for installation in distribution panels
Light‑grey enclosure in RAL 7035

Approvals
A UL 508, CAN/CSA C22.2 No.14
H UL 1310, CAN/CSA C22.2 No.223
(Class 2 Power Supply)
H UL 60950, CAN/CSA C22.2 No.60950
GOST
D
CCC
E
*) Approval refers to rated input voltage Uin
~

*)
*)
*)
*)

e  Circuit diagram

Marks
a
b

CE
C‑Tick

pending

Order data
Type

Input voltage range

Rated output voltage /
current

Order code

CP-D 12/0.83

90‑264 V AC /
120-375 V DC

12 V DC / 0.83 A

1SVR 427 041 R1000

Application
The primary switch mode power supply has two voltage input ranges. This enables the supply with
AC or DC. Furthermore it is equipped with two generous capacitors, which ensure mains buffering of
at least 30 ms. That is why the device can be used worldwide also in high fluctuating networks and
battery‑powered plants.

Installation

The switch mode power supply can be snapped on a DIN rail according
to IEC/EN 60715 as shown in the accompanying picture. For that
the device is set with its mounting rail slide on the upper edge of the
mounting rail and locked by lifting it downwards.

ABB

2CDC 272 040 F0b07

Mounting

1

Power supply CP-D 12/0.83
Primary switch mode power supply
Data sheet
Installation

Demounting

2CDC 272 041 F0b07

Remove the switch mode power supply as shown in the accompanying
picture. For that the latching lever is pulled downwards by means of the
screwdriver. Alternatively you can press the unlock button to release the
device. Then in both cases the device can be unhinged from the mounting
rail edge and removed.

Mounting position

2CDC 272 042 F0b07

The devices have to be mounted horizontally with the input terminals
on the bottom. In order to ensure a sufficient convection, the minimum
distance to other modules should not be less than 25 mm in vertical
direction and horizontal direction.

Electrical connection
Connect the input terminals L and N. The installation must be executed acc. to EN 60950, provide a
suitable disconnecting device (e. g. line protection switch) in the supply line. The input side is protected
by an internal input fuse.
Rate the lines for the maximum output current or provide a separate fuse protection. We recommend to
choose the cable section as large as possible in order to minimize voltage drops. Observe the polarity.
Actuate plug connector only when power is off. The device is overload, short‑circuit and open‑circuit
proof. The secondary side of the power supply is electrically isolated from the input and internally not
earthed (SELV) and can therefore be earthed by the user according to the needs with + or ‑ (PELV).

Connection diagram(s)
-

L

+
PWM

N

L

2

-

N

2CDC 272 038 F0b07

+

+, ‑
L, N

Output voltage
Input voltage

ABB

Power supply CP-D 12/0.83
Primary switch mode power supply
Data sheet
Safety instructions and warnings
The device must be installed by qualified persons only and in accordance with the specific national
regulations (e. g. VDE, etc.).
CP‑D power supplies are chassis‑mounted units. They are maintenance‑free and do not contain any
integral
setting elements and should therefore not be opend.
Before any installation, maintenance or modification work:
Disconnect the system from the supply network and protect against switching on!
Before start of operation the following must be ensured:
 Connect to main according to the specific national regulations.
 Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided
for the end product to disengage unit and supply cables from supply mains if required.
 Rate the output lines for the output current of the power supply and connect them with the correct
polarity.
 In order to ensure sufficient air‑cooling the distance to the other devices has to be considered.
Attention! Improper installation/operation may impair safety and cause operational difficulties or
destruction of the unit.
In operation pay attention to:
 Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and
electric shock (danger to life)!
 Risk of burns: Depending on the operation conditions the enclosure can become very hot.
 If the internal fuse blows, most probably the device is defect. In this case, an examination of the
switch mode power supply by the manufacturer is necessary.

Attention! Danger to life!
Disconnect the system from the supply network before executing any works at the device and protect
against switching on!
The power supply contains components with high stored energy and circuits with high voltage! Do not
introduce any objects into the unit and do not open the unit.
With some units of this range the output is capable of providing hazardous energy. Ensure that the
service personnel is protected against inadvertent contact with parts carrying energy.

ABB

3

Power supply CP-D 12/0.83
Primary switch mode power supply
Data sheet
Technical data
Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated
Input circuits - Supply circuits

1SVR 427 041 R1000

Rated input voltage Uin

L, N

Typical input current / power consumption
100‑240 V AC
Input voltage range
Frequency range

90‑264 V AC
120‑375 V DC

AC

47‑63 Hz
30 A max. 3 ms
min. 30 ms

Internal input fuse (apparatus protection, not accessible)

1 A slow‑acting / 250 V AC

Power factor correction (PFC)

no

Indication of operational states

1SVR 427 041 R1000
DC ON: green LED

V: output voltage applied

DC LOW: red LED

V: output voltage too low

Output circuits

1SVR 427 041 R1000
+, ‑

Tolerance of the output voltage

Derating of the output current
Deviation

10 W
Ta ≤ 60 °C

Rise time
Residual ripple and switching peaks

0.83 A

60 °C < Ta ≤ 70 °C

2.5 %/°C

load change statical

max. 1 %

change of output voltage
within the input voltage range

max. 1 %

Control time
Starting time after applying supply voltage

12 V DC
± 1 %

Rated output power
Rated output current Ir

230 V AC
128.3 mA / 13.01 W

AC

Power failure buffering time

Rated output voltage

110 V AC
200 mA / 12.68 W

DC
Inrush current limiting

Output voltage

100‑240 V AC

< 1 ms
at Ir

1000 ms

at rated load

typ. 1 ms

BW = 20 MHz

50 mV

Parallel connection

yes, use of CP-D RU required

Series connection

yes, to increase voltage

Resistance to reverse feed

18 V / 1 s

Characteristic curve of output

U/I characteristic curve

Short‑circuit protection

continuous short‑circuit stability

Short‑circuit behaviour

continuation with output power limiting

Current limiting at short circuit

typ. 1.4 A

Overload protection

output power limiting

Overvoltage protection

15-16.5 V DC

No‑load protection

continuous no‑load stability

Starting of capacitive loads

unlimited

General data

1SVR 427 041 R1000

Duty time

100 %

Dimensions (W x H x D)
Material of housing
4

18 x 91 x 57.5 mm
(0.71 x 3.58 x 2.26 inches)
housing

Plastic

ABB

Power supply CP-D 12/0.83
Primary switch mode power supply
Data sheet
General data

1SVR 427 041 R1000

Efficiency

typ. 78 %

Weight

0.066 kg (0.13 lb)

Mounting position

horizontal

Minimum distance to other units
normal operation mode

horizontal

25 mm (0.98 inch)

vertical

25 mm (0.98 inch)

Mounting
Degree of protection

DIN rail (IEC/EN 60715),
snap‑on mounting without any tool
housing / terminals

Class of protection

II

Electrical connection

1SVR 427 041 R1000

Input circuit / Output circuit
Wire size

Screw connection
fine‑strand with wire end
ferrule

0.2‑1.5 mm2
(24‑16 AWG)

rigid

0.2‑2.5 mm2
(26‑12 AWG)

Stripping length

4-5 mm (0.16-0.2 in)

Tightening torque

0.6 Nm (5 lb.in)

Environmental data
Ambient temperature range

IP20 / IP20

1SVR 427 041 R1000
operation

‑40...+70 °C

full load

‑40...+60 °C

storage

‑40...+85 °C

Damp heat, cyclic (IEC/EN 60068‑2‑30)

4 x 24 h cycles, 40 °C, 95 % RH

Vibration, half‑sine (IEC/EN 60068‑2‑6)

50 m/s2, 10 Hz ‑ 2 kHz

Shock, half‑sine (IEC/EN 60068‑2‑27)

40 m/s2, 22 ms

Isolation data
Rated isolation voltage Ui

1SVR 427 041 R1000
input circuit / output circuit

3 kV AC

Pollution degree

2

Overvoltage category (UL/IEC/EN 60950-1)

II

Standards / Directives

1SVR 427 041 R1000

Product standard

EN 61204

EMC Directive

2004/108/EC

Low Voltage Directive

2006/95/EC

Electrical safety

UL 508, UL 60950‑1, EN 60950‑1

Protective low voltage

SELV (EN 60950‑1)

Electromagnetic compatibility

1SVR 427 041 R1000

Interference immunity to

IEC/EN 61000‑6‑2

electrostatic discharge

IEC/EN 61000‑4‑2

Level 4 (4 kV / 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000‑4‑3

Level 3 (10 V/m)

electrical fast transient / burst

IEC/EN 61000‑4‑4

Level 4 (4 kV)

surge

IEC/EN 61000‑4‑5

Level 3 (2 kV L‑L)

conducted disturbances, induced by radiofrequency fields

IEC/EN 61000‑4‑6

Level 3 (10 V)

ABB

5

Power supply CP-D 12/0.83
Primary switch mode power supply
Data sheet
Electromagnetic compatibility

1SVR 427 041 R1000

Interference emission

6

IEC/EN 61000‑6‑3

high-frequency radiated

IEC/CISPR 22, EN 55022

Class B

high-frequency conducted

IEC/CISPR 22, EN 55022

Class B

ABB

Power supply CP-D 12/0.83
Primary switch mode power supply
Data sheet
Technical diagrams
Output behaviour
12
11
10
9
8
7
6
5
4
3
2
1
0
0.25

0

0.5

0.75

1

1.25
Iout [A]

2CDC 272 019 F0207

Uout [V]

Characteristic curve of output at Ta = 25 °C
The switch mode power supply CP‑D 12/0.83 is able to supply at 12 V DC output voltage and
 at an ambient temperature of:
≤ 60 °C a continuous output current of approx. 0.83 A
 at ambient temperatures of:
60 °C < Ta ≤ 70 °C the output power has to be reduced by 2,5 % per °C temperature increase.
If the switch mode power supply is loaded with an output current > 0.83 A, the operating point is
passing through the U/I characteristic curve shown.
 

Temperature behaviour

100
90
80
70
60
50
40
30
20
10
-10

0

10

20

30

40

50

60

70

Ta [°C]

2CDC 272 018 F0207

Pout [%]

Characteristic curve of temperature at Uout

Dimensions
in mm
18,0 [0.71”]

67,0 [2.64”]

57,5 [2.26”]

2CDC 272 011 F0b07

49,0 [1.93”]

32,1 [1.26”]

91,0 [3.58”]

44,5 [1.75”]

CP-D 12/0.83

ABB

7

Power supply CP-D 12/0.83
Primary switch mode power supply
Data sheet
Further Documentation
Document title

Document type

Document number

Electronic Products and Relays

Technical catalogue

2CDC 110 004 C02xx

Power Supply Units

Application manual

2CDC 114 048 M020x

You can find the documentation on the internet at www.abb.com/lowvoltage R Control Products R Power Supplies

8

ABB

Contact us

Document number 2CDC 114 052 D0201 (02/12)

ABB STOTZ-KONTAKT GmbH
P. O. Box 10 16 80
69006 Heidelberg, Germany
Phone: +49 (0) 6221 7 01-0
Fax: +49 (0) 6221 7 01-13 25
E-mail: info.desto@de.abb.com
You can find the address of your
local sales organisation on the
ABB home page
http://www.abb.com/contacts
-> Low Voltage Products and Systems

Note:
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB AG does not accept
any responsibility whatsoever for potential errors or
possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents – in whole or in parts – is
forbidden without prior written consent of ABB AG.
Copyright© 2010 ABB
All rights reserved



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Create Date                     : 2012:02:13 14:30:07+01:00
Metadata Date                   : 2012:02:13 14:31:06+01:00
Modify Date                     : 2012:02:13 14:31:06+01:00
Creator Tool                    : Adobe InDesign CS5 (7.0.4)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 8037 bytes, use -b option to extract), (Binary data 6090 bytes, use -b option to extract)
Instance ID                     : uuid:75d6282b-0dae-4a18-a496-7f3e6c59f3c1
Document ID                     : xmp.did:638D5ADC3608E011AAF496DAE2721608
Original Document ID            : adobe:docid:indd:9bb419ce-f5c5-11dc-8fb5-88e1111732ec
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:628D5ADC3608E011AAF496DAE2721608
Derived From Document ID        : adobe:docid:indd:9bb419ce-f5c5-11dc-8fb5-88e1111732ec
Derived From Original Document ID: adobe:docid:indd:9bb419ce-f5c5-11dc-8fb5-88e1111732ec
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:E671DD760E02E0118749FA0A809647F6, xmp.iid:E771DD760E02E0118749FA0A809647F6, xmp.iid:8638AD26A602E011BA07E07F83136F78, xmp.iid:7358C256A702E011BA07E07F83136F78, xmp.iid:628D5ADC3608E011AAF496DAE2721608, xmp.iid:638D5ADC3608E011AAF496DAE2721608, xmp.iid:4C7DF3913708E011AAF496DAE2721608, xmp.iid:BF6A668F3156E11192B6DED1E5FF53FB, xmp.iid:C06A668F3156E11192B6DED1E5FF53FB, xmp.iid:D5947B9C3956E11192B6DED1E5FF53FB, xmp.iid:F77A6F6D3C56E11192B6DED1E5FF53FB
History When                    : 2010:12:07 15:30:18+01:00, 2010:12:07 15:30:18+01:00, 2010:12:08 09:42:36+01:00, 2010:12:08 10:08:19+01:00, 2010:12:15 11:34:44+01:00, 2010:12:15 11:34:44+01:00, 2010:12:15 14:16:11+01:00, 2012:02:13 11:57:45+01:00, 2012:02:13 11:57:45+01:00, 2012:02:13 12:55:23+01:00, 2012:02:13 13:15:33+01:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /, /metadata, /, /, /metadata, /;/metadata, /, /;/metadata, /metadata, /;/metadata, /;/metadata
Format                          : application/pdf
Title                           : Primary switch mode power supply CP-D 12/0.83
Creator                         : ABB Stotz-Kontakt GmbH
Description                     : Data sheet
Authors Position                : Data sheet - CP-D 12/0.83 - Primary switch mode power supplies
Startup Profile                 : Print
Doc Change Count                : 328
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
GTS PDFX Version                : PDF/X-4
Page Count                      : 9
Author                          : ABB Stotz-Kontakt GmbH
Subject                         : Data sheet
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu