Product Detail Manual
2014-09-05
: Pdf 118928-Attachment 118928-Attachment 783643 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 33
Download | |
Open PDF In Browser | View PDF |
Selection and application guide For use in Kansas, Iowa, Missouri and Illinois Meter mounting equipment www.landisandgyr.com Contents Service Rating Positions Terminals Page Introduction and General Information - - - 3-7 Residential, 1 Phase, 3 Wire 135A 1 4&5 8 Residential, 1 Phase, 3 Wire 200A 1 4&5 9 Residential, 1 Phase, 3 Wire, Horizontal Gang 100/150A 2-4 4 10 Residential, 1 Phase, 3 Wire, Horizontal Gang 200A 2-6 4 11 Commercial/Industrial, 1 and 3 Phase, 3 Wire 200A 1 5&7 12 Commercial/Industrial, 1 Phase, 3 Wire, Polyphase, 3 or 4 Wire 200A 1 4, 5 & 7 13 Commercial, 1 Phase, 3 Wire, Polyphase, 4 Wire 320A 1 4, 5 & 7 14 Residential, 1 Phase, 3 Wire, Multi-Position, Lever Bypass 200A 2-6 4, 5 & 7 15 Commercial/Industrial, Type PTS Transformer Rated 20A 1 - 16 Residential, 1 Phase, 3 wire, Type K4 400/480A 1 4 17 Residential/Commercial/Industrial, Polyphase, 3 or 4 Wire 400/480A 1 7 18 Residential, Type AP Pedestal, 1 Phase, 3 Wire 200/320A 1 4&5 19 Residential/Commercial/Industrial Pedestal Type HQ 200/400A 1 5 20 Residential, Meter Mains 100/200A 1 4&5 21 Residential, Meter Mains 200/400A 1 4&5 22 Circuit Breakers - - - 23 Air Conditioning Disconnects - - - 24 Spa Panels - - - 25 Lugs - - - 26, 27 Socket Accessories - - - 28 Repair Parts, Terms & Conditions and Device Applications - - - 29 2 The Standard for Quality For more than 50 years, Landis & Gyr has been manufacturing high quality meter mounting devices. From our proprietary K-Base to our heavy duty HQ lever bypass socket, Landis & Gyr is known throughout the industry for innovation and quality. Landis & Gyr meter sockets are built for safety, ease of installation, and long term quality. That's why we use stainless steel hardware, polyester powder coat paint for long lasting protection, and Type G-90 galvanized steel or 3003 grade aluminum for all of our enclosures. It's also why we use an all-copper current path in our commercial sockets. All of this adds up to why utilities, OEM's, and contractors recognize Landis & Gyr across the country as the leader in design, quality, and workmanship. Quality is the reason many utilities and electricians specify Landis & Gyr. HQ-7 Block Assembly - The Standard for Quality Landis & Gyr- the standard for quality and design. General Information Materials: 16 gauge, galvanized steel, G-90 14 gauge, galvanized steel, G-90 14 gauge, aluminum 12 gauge, aluminum Enclosures: NEMA 3R Finish: Steel - Light gray, baked on powder polyester Aluminum - Mill finish 3 Latches: All swing latches are stainless steel Block Material: AS/AT, CQ, HQ, K-4 and K-7 - Glass reinforced polyester Terminals: AS/AT - Tin-plated aluminum extrusions 6061-T6 CQ, HQ, - Tin-plated copper Standards: Products cataloged herein meet or exceed the following standards: UL 486B, UL 414, NEMA 250, ANSI C12.7 Florida Meter Group requirements Voltage: All devices are rated at 600V AC Type K-4 rated at 300V AC Meter Socket Terminology Maximum and Continuous Ampacity UL and NEMA standards allow most electrical devices to be tested at one amp level ("continuous"), then allowed 125% rating as "maximum". For example, a "400 Amp" socket may either mean 400 Amps continuous (K-4) or 400A Max, 320A continuous which is also made by most competitors. Ringless/Ring Style Ring-type is an older, vanishing concept requiring a sealing ring. Landis & Gyr recently added tooling to build this type of socket for the few remaining utilities that require them. In ringless design, the seal is made not on a sealing ring but using the cover and "swing latch" as the point of sealing. Wire Sizes - Ampacity Connectors accept a fairly wide variety of wire sizes. On the AT socket, a 350 MCM connector accepts conductors from #6 up to 350 MCM. The NEC specifies the ampacity of each wire size and type, also taking into account how the wire is installed in conduit. Overhead/Underground Sockets for UG service are usually wider in order to provide space for the conductors to loop around the block to the top connectors. Since more material is required in the enclosure, UG sockets are more expensive than OH sockets. Quite popular are combination units (OH/UG) which may be used in either service, and require a cover plate if used with UG feed. Lay-in & Stud Terminals Lay-in terminals are fixed and may not be modified in the field to accept other wire sizes or parallel conductors. Stud terminals accept either lugs (see Product Schedule 497) or compression fittings (not available from Landis & Gyr). Common uses for studs include where the field wiring may be either single or parallel. Terminals may be mixed on the line and load sides, e.g. stud on the line and lay-in on the load side. Hubs and Cover Plates Top of socket with hub opening has a flanged lip to keep out moisture. This requires a hub or cover plate to close. There are two sizes of openings: "small" for conduit hubs with sizes of 1", 1-1/4", 1-1/2", 2", and 2-1/2"; and "large" for conduit hubs with sizes 3", 3-1/2", and 4". See Product Schedule 499. Landis & Gyr hub openings conform to ANSI C12.7 specs and are interchangeable with other socket manufacturers, but are not interchangeable with panel board style hubs. Bypass Types A self-contained meter completes the circuit between the utility and the customer. In order to change the meter, the circuit must be broken, turning off the power to the customer. This is not acceptable in commercial establishments, or in many other types of services. A bypass allows a parallel path for the current flow, un-metered, while the meter is pulled. Types are: a) b) c) d) e) Lever-operated jaw release, also known as jaw clamping lever bypass (Landis & Gyr type HQ). The best, because the meter cannot accidentally be pulled unless the bypass is engaged. Pulling the meter would also be a major safety hazard if there is a 480V installation and/or a large load in place, as the meter would then act as a switch, and cause arc. Lever-operated non-jaw release (Landis & Gyr type CQ). Lever bypasses the meter, but the meter may be removed with the bypass open. Horn bypass (option on residential sockets). Tangs on line and load connectors allow for jumper leads to be fitted over them before the meter is pulled. Manual bypass (K-4, K-5, K-7) uses separate "links", which are clamped onto special studs before the meter is removed. K-7 also uses a "rotating link" type bypass. Other types not made by Landis & Gyr include: slide links, screw type, and automatic circuit closers. 4 Q & A Product Sheets Q. How can I find a missing “lug” for a (Catalog No.____________________) meter socket? A. If the socket is a residential type, the customer usually needs the nut/screw assembly that clamps the wire into place in a lay-in style connector. There are different types of nut/screws. You will need to determine the catalog number of the device, and if it is to be used on the line side, load side or neutral. With a commercial device, the customer may look for a ground lug or mechanical lug for a stud type meter socket. In these cases the customer should contact a technical support person, or refer to the specification sheet for the correct lug. The customer may mistake the number, that is stamped on the part, (e.g. “6T0350”) as the catalog number. This is actually the wire size that is stamped into the nut/screw assembly for a HQ style device. “6 TO 350” refers to the wire size range of the connector. Q. How can I find a replacement insulator, block, or porcelain/ceramic insulator? A. First, determine the catalog number of the device. After the device has been identified you can then inquire if it is “left hand or right hand”, and if it is used on a side wired device or a multi-position gang socket. On standard residential sockets, the right and left hand blocks are identical, and are mounted in a mirror image of each other. Q. What size hub can I use on a RX or HD hub opening? A. A RX style hub opening will accept a 1” to 2-1/2” hub. A HD style hub opening will accept a 3” to 4” hub. Q. How can I permanently close the meter opening of my meter socket without a meter in place? A. A round black plastic disk (Catalog No. H39968) is available. It is located between the meter socket block assembly and the meter socket cover. The cover holds the disk into place. This is used on residential and most commercial sockets that have embossed meter openings in the socket cover. Q. What do I use to close the meter opening, and also permanently jumper the meter socket so that the end user still gets power, although unmetered? A. For all devices with jaws, use jumper (Catalog No. H36479). Two jumpers are needed for a single phase device and three for a three phase device. Q. What if I need an isolated neutral? A. Some applications require the neutral connection to be isolated or insulated. Isolated neutral kits are available for CQ and HQ (Catalog No.H64685-1) and K-7 devices (Catalog No.H69685-1). Q. What if I need a 5th Jaw or 5th Terminal? A. Residential sockets (type UAXXXX) use two different types of field installable 5th terminals. Catalog No. H659-0121 for a grounded 5th terminal is most commonly used. Use Catalog No. H659-0120 when the 5th terminal does not need to be grounded. The 5th terminal for a HQ device (Catalog No. H35815-2) is in the form of a polycarbonate, safety shield with the 5th terminal located in the 9 o’clock position. Q. What lugs should I use for a particular meter socket? A. 5 Lugs are included on most residential devices. A limited number of residential devices are available with stud connections. Commercial devices (HQ, CQ, K Base) have either the lug as an integral part of the socket (200amp HQ only) or have 3/8" or 1/2" stud connections. The catalog page for each commercial device with stud connections includes a list of recommended lugs. Lugs with an opening size of 13/32" are for 3/8" studs and lugs with an opening of 9/16" are for ½" studs. Lugs should be chosen based on the size and number of conductors being pulled to the socket. Some lugs are for specific types of sockets (K Base or HQ). Please refer to the accessories page for more details. Q & A Product Sheets Q. What is the voltage rating for Landis & Gyr meter sockets? A. All meter sockets manufactured by Landis & Gyr are rated for up to 600 volts, with the exception of type K-4, which is rated at 300 volts. Q. What material is used for the Landis & Gyr meter socket enclosures? A. Landis & Gyr uses type G-90 galvanized steel and aluminum for its enclosures. Pedestals used in Chicago use G-210 steel. Q. What type of finish is applied to the enclosures? A. Landis & Gyr has a high quality reputation for its gray, baked on polyester powder coat, which is long lasting and withstands salt spray testing. Aluminum enclosures are normally supplied unpainted, but can be supplied with the same polyester coating as used on steel. Q. What rating do Landis & Gyr meter socket enclosures carry? A. Landis & Gyr enclosures have a NEMA type 3R rating. Q. Are Landis & Gyr meter sockets UL listed? A. Landis & Gyr offers all of its product lines with the UL listing. On occasion, we supply special devices that are not UL listed, to utilities that do not require the UL label. Q. What label information can be found on the inside of the meter socket? A. Every Landis & Gyr meter socket has a white information label, approximately 2-1/2” x 4” in size. It is located on the upper left hand inside wall of the enclosure. This label contains the following information: Catalog Number, Socket Type (UAT4, HQ-7U etc.), Number of Terminals (jaws), Continuous/Maximum Amperage, Voltage Rating, Service (single phase or three phase), Short Circuit Withstand Rating, Other UL Information, Included lay-in connector sizes or recommended lugs if stud type, Conduit Hub Kit Options and Accessories, where the device is manufactured and the date it was manufactured. Q. How do I find the production date code for a Landis & Gyr meter socket? A. The date code is printed towards the center of the bottom of the interior label. The date code will specify the month and year the socket was manufactured. Q. What is the difference between 320 Amp sockets with 3/8" studs and those with 1/2" studs? A. Landis & Gyr was the pioneer of class 320 metering. Originally it was believed that a socket with heavy duty connectors and jaw assemblies were needed to withstand this "high" amperage. Landis & Gyr introduced the HQ-D type block which features heavy plated copper connectors and 1/2" studs for mounting mechanical lugs. After receiving requests for a lighter-duty socket Landis & Gyr introduced the HQ-S type block. This block features the same heavy-duty connectors, but has 3/8" studs for mounting the mechanical lugs. Check with your local utility to see which block style is preferred. Q. What is an anti-inversion clip? A. The anti-inversion clip (Catalog No. H59676) is a specially formed wire that is inserted into the upper right hand jaw of a 320A meter socket. The purpose of the clip is to disallow a 200A meter to be inserted into the 320A meter socket. Class 320 meters are built with a narrow blade that will fit into a jaw that has the anti-inversion clip installed. The anti-inversion clip also restricts a class 320 meter from being inserted upside down. 6 Q & A Product Sheets Q. What type of information can I find in the Landis & Gyr catalog? A. Landis & Gyr publishes two types of catalogs. Our general catalog has Product Schedules containing detailed information for each type of product Landis & Gyr manufactures. Product Schedule #400 outlines the complete product offering and guides the user to the correct Product Schedule based on criteria such as: electrical service, form of meter being used, number of terminals (jaws), amperage, etc. Special accessories schedules near the back of the catalog show bypasses, tools, hubs and cover plates, 5th terminal kits, isolated neutral kits and ring-type socket sealing rings. Landis & Gyr also publishes special catalogs for NEMRA trade territories, based on utility requirements. These catalogs are provided for the Contractor and Industrial (C & I) distribution market by authorized Landis & Gyr manufacturer representative organizations. These catalogs show only the products that pertain to the specific service territory. The C & I catalogs also include special accessories and lug information on the back pages. For detailed product information, customers can be referred to the corresponding Product Schedule in the general catalog. Q. What is K-base? A. K-base is the term used for a special way of metering continuous amperages of 400A or higher. Before the introduction of K-base metering, which was pioneered by Landis & Gyr, all loads over 320A had to use transformer rated metering. The K-base concept employs a meter with internal transformers to accept loads of up to 600A maximum and a meter-mounting device with heavy-duty bussing that holds the meter in place with the use of bolts. K-base meters and mounting devices are available for single phase, network and three phase applications. The K-base concept is continually growing as new utilities approve its usage each year. Q. Which socket do I choose for a 400 Amp application? A. There are 3 ways of metering a 400A application. Some utilities prefer a 320A meter socket, some prefer a 400A K base, still others prefer to use current transformers. Your local utility could use one or a combination of any of these methods. Please contact your local utility prior to purchasing a socket to ensure you have the right device for your application. Q. What is the difference between an RX hub and a HD hub? A. 7 The RX hub is a small base ANSI compliant hub. The size ranges from 3/4” to 2-1/2”. The HD hub is a large base ANSI compliant hub. The size ranges from 3” to 4”. An HD size opening may be reduced to an RX size using an accessory adaptor plate. 135A Continuous, Meter Mounting Equipment, Residential 4 & 5 Terminal for 1 Phase, 3 Wire Service Connectors Line Load Dimensions (inches) W H D Hub Opening Enclosure Material Catalog Number None Steel UAT111-0G None Steel UAT111-0P None Steel UAT111-0PQG None Steel UAT111-BPQG None Steel UAT111-XMBL All units include a quad neutral. 5th terminal for field installation: H659-0121. UAT1X1 UAT111-0G KNOCKOUTS (inches): 䊎: L: N: R: RX: 1/4 1/2, 3/4, 1, 1-1/4, 1-1/2 3/4, 1, 1-1/4, 1-1/2, 2 1, 1-1/4, 1-1/2, 2 쏗2.750 HUB 0P 8 Residential Approved for Ameren, Mid American Energy Co., Midwest Power (Two Rivers Serv.Cen.) 135 OH/UG #14-2/0 #14-2/0 8.0 11.7 3.6 RX Opening Approved for Alliant Energy (Interstate P&L) 135 OH/UG #14-2/0 #14-2/0 8.0 11.7 3.6 RX Opening Approved for Ameren, Mid American Energy Co., Xcel Energy 135 OH/UG #14-2/0 #14-2/0 8.0 11.7 3.6 RX Opening Approved for Ameren 135 OH/UG #14-2/0 #14-2/0 8.0 11.7 3.6 RX Opening Approved for Ameren. Mid American Energy Co., Xcel Energy 135 OH/UG #14-2/0 #14-2/0 8.0 11.7 3.6 RX Opening Bypass 135 Amp - 4 & 5 Jaw - Ringless Cont. Amp Rating 200A Meter Mounting Equipment, Residential Residential 200 Amp - 4 & 5 Jaw - Ringless 4 & 5 Terminal for 1 Phase, 3 Wire Cont. Amp ConnectorsDimensions (inches) Hub Enclosure Catalog Rating Service Line & Load W H D Opening Bypass Material Approved for Ameren, Mid American Energy Co., Midwest Power (Two Rivers Serv. Cen.) 200 OH #6-350 KCMIL 8.0 14.0 4.5 RX Opening None Steel Approved for Aliant Energy (Interstate P&L) 200 OH #6-350 KCMIL 8.0 14.0 4.5 RX Opening Horn Steel 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 Cover Plate Horn Steel Approved for Commonwealth Edison (Excelon) 200 OH #6-350 KCMIL 8.0 14.0 4.5 RX Opening Horn Steel 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 RX Opening Horn Steel Approved for Ameren, Mid American Energy Co. 200 OH #6-350 KCMIL 8.0 14.0 4.5 RX Opening Horn Steel Approved for Ameren 200 OH #6-350 KCMIL 8.0 14.0 4.5 2” Hub Installed None Steel Approved for Ameren, Xcel Energy 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 RX Opening None Steel 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 RX Opening Horn Steel Approved for Ameren, Mid American Energy Co. 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 Blank Top None Steel 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 Blank Top Horn Steel 200 OH/UG #6-350 KCMIL Steel Approved for Kansas City Power and Light, Mid American Energy Co., Midwest Power (Two Rivers Serv. Cen., Xcel Energy 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 Cover Plate Horn Steel Approved for Ameren, Commonwealth Edision (Excelon), Mid American Energy Co. 200 OH/UG #6-350 KCMIL 11.0 14.0 4.5 Cover Plate Horn Steel Number UAT317-0G UAT317-0P UAT417-XP UAT317-0PCH UAT417-0PZ UAT317-0PQG UAT317-DG UAT417-0G UAT417-0PQG UAT417-PG UAT417-PPQG UAT417-XVZ UAT417-XG UAT417-XPQG All units include a ground lug. 5th terminal installed, barrel lock KO. 5th terminal for field installation: H659-0121. UAT317-0G UAT417-XG KNOCKOUTS (inches): UAT3X7 9 UAT4X7 䊎: A: S: AB: AC: AD: RX: 1/4 1/2 1, 1-1/4, 1-1/2, 2, 2-1/2 1/4, 1/2, 7/8 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗2.750 HUB 0P 4 Terminal for 1 Phase, 3 Wire No. Pos. Cont. Amp Rating Service Connectors Line Connectors Load Dimensions (inches) W H D Approved for Ameren, Midwest Power (Two Rivers Serc. Cen.) 2 100 OH/UG #6-350 KCMIL #14-2/0 24.0 Hub Opening Bypass Enclosure Material Catalog Number 12.0 4.5 RX Opening None Steel UA2311-0G 2 150 OH/UG #6-350 KCMIL #6-350 KCMIL 24.0 12.0 4.5 RX Opening None Steel UA2313-0G 3 150 OH/UG #6-350 KCMIL #6-350 KCMIL 32.0 12.0 4.5 RX Opening None Steel UA3313-0G 4 150 OH/UG #6-350 KCMIL #6-350 KCMIL Approved for Alliant Energy (Interstate P&L) 2 100 OH/UG #6-350 KCMIL #14-2/0 3 100 OH/UG #6-350 KCMIL #14-2/0 4 100 OH/UG #6-350 KCMIL #14-2/0 Approved for Commonwealth Edison (Excelon) 2 100 OH/UG #6-350 KCMIL #14-2/0 40.0 12.0 4.5 RX Opening None Steel UA4313-0G 24.0 32.0 40.0 12.0 12.0 12.0 4.5 4.5 4.5 RX Opening Horn RX Opening Horn RX Opening Horn Steel Steel Steel UA2311-0P UA3311-0P UA4311-0P 3 100 OH/UG #6-350 KCMIL #14-2/0 24.0 12.0 4.5 RX Opening Horn Steel UA2311-0PCH 32.0 12.0 4.5 RX Opening Horn Steel UA3311-0PCH Horn Steel UA4311-0PCH Horn Steel UA2311-0PQG Horn Horn Horn Steel Steel Steel UA2311-XBBU UA3311-XBBU UA4311-XBBU Horn Horn Steel Steel UA3311-OPQG UA4311-OPQG 4 100 OH/UG #6-350 KCMIL #14-2/0 40.0 12.0 4.5 RX Opening Approved for Alliant Energy (Interstate P&L), Ameren 2 100 OH/UG #6-350 KCMIL #14-2/0 24.0 12.0 4.5 RX Opening Approved for Kansas City Power and Light 2 100 OH/UG #6-350 KCMIL #14-2/0 24.0 12.0 4.5 RX Cl. Plate 3 100 OH/UG #6-350 KCMIL #14-2/0 32.0 12.0 4.5 RX Cl. Plate 4 100 OH/UG #6-350 KCMIL #14-2/0 40.0 12.0 4.5 RX Cl. Plate Approved for Alliant Energy (Interstate P&L), Ameren, Midwest Power (Two Rivers Serv. Cen.) 3 100 OH/UG #6-350 KCMIL #14-2/0 32.0 12.0 4.5 RX Opening 4 100 OH/UG #6-350 KCMIL #14-2/0 40.0 12.0 4.5 RX Opening All units are equipped with a ground lug. All sockets are suitable for either overhead or underground feed. 5th Terminal Kit for field installation: H659-0121. Sockets with “QG” suffix are equipped with 2 ground lugs. KNOCKOUTS (inches): S: AC: RX: 1, 1-1/4, 1-1/2, 2, 2-1/2 1/4, 1/2 쏗2.750 HUB 0P UA2311-0PQG with H659-0121 installed UA2311/2313 UA3311/3313 UA4311/4313 10 Residential 100/150 Amp - 4 Jaw - Horizontal Gang 100A/150A Position Meter Mounting Equipment, Horizontal Gang, Residential Residential 200 Amp - 4 & 5 Jaw - Horizontal Gang 200A/Position Meter Mounting Equipment, Horizontal Gang, Residential 4 & 5 Terminal for 1 Phase, 3 Wire No. Cont. Amps Pos. Rating Service Connectors Line Connectors Load Dimensions (inches) Hub W H D Opening Enclosure Bypass Material Catalog Number HD Opening None Steel UA2716-YG 2 200 OH/UG #6-350 KCMIL #6-350 KCMIL 24.0 14.5 5.1 HD Cover Pl. Approved for Ameren, Midwest Power (Two Rivers Serv. Cen.), Alliant Energy (Interstate P&L) 2 200 OH/UG 1/0-600 KCMIL #6-350 KCMIL 24.0 14.5 5.1 HD Opening Horn Steel UA2716-ZBBU Approved for Mid American Energy Co., Midwest Power (Two Rivers Serv. Cen.) 2 200 OH/UG #6-350 KCMIL #6-350 KCMIL 24.0 14.5 5.1 Approved for Kansas City Power and Light 4 200 OH/UG (2)1/0-600 KCMIL #6-350 KCMIL 5 200 OH/UG (2)1/0-600 KCMIL #6-350 KCMIL 6 200 OH/UG (2)1/0-600 KCMIL #6-350 KCMIL Approved for Commonwealth Edison (Excelon) 2 200 OH/UG 1/0-600 KCMIL #6-350 KCMIL 3 200 OH/UG 1/0-600 KCMIL #6-350 KCMIL 4 200 OH/UG (2)1/0-600 KCMIL #6-350 KCMIL 5 200 OH/UG (2)1/0-600 KCMIL #6-350 KCMIL 6 200 OH/UG (2)1/0-600 KCMIL #6-350 KCMIL Approved for Alliant Energy (Interstate P&L), Ameren 2 200 OH/UG 1/0-600 KCMIL #6-350 KCMIL 3 200 OH/UG 1/0-600 KCMIL #6-350 KCMIL Approved for Midwest Power (Two Rivers Serv. Cen.) 3 4 200 200 OH/UG OH/UG 1/0-600 KCMIL #6-350 KCMIL (2)1/0-600 KCMIL #6-350 KCMIL None Steel UA2717-YG 43.0 51.0 59.0 14.5 14.5 14.5 5.1 5.1 5.1 HD Opening Horn (2) HD Openings Horn (2) HD Openings Horn Steel Steel Steel UA4719-YPQG UA5719-KPQG UA6719-KPQG 24.0 32.0 14.5 14.5 5.1 5.1 HD Opening HD Opening Horn Horn Steel Steel UA2717-YPCH UA3717-YPCH 43.0 51.0 59.0 14.5 14.5 14.5 5.1 5.1 5.1 HD Opening Horn (2) HD Openings Horn (2) HD Openings Horn Steel Steel Steel UA4719-YPCH UA5719-KPCH UA6719-KPCH 24.0 32.0 14.5 14.5 5.1 5.1 HD Opening HD Opening Horn Horn Steel Steel UA2717-YPQG UA3717-YPQG 32.0 43.0 14.5 14.5 5.1 5.1 HD Opening HD Opening None None Steel Steel UA3717-YG UA4719-YG All units are equipped with a ground lugs. All sockets are suitable for either overhead or underground feed. 5th Terminal Kit for field installation: H659-0121. Sockets with “QG” suffix have 2 ground lugs. KNOCKOUTS (inches): X: AC: AD: HD: UA3717 11 UA2717 1-1/4, 1-1/2, 2, 2-1/2 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P UA2717-YG UA4719 UA5719 UA6719 200A Meter Mounting Equipment, Type CQ, Commercial/Industrial 5 and 7 Terminal for 1 Phase and 3 Phase, 3 Wire Connectors Line & Load Dimensions (in) W H D Hub Opening No. of Term. Enclosure Material Catalog Number #6-350 KCMIL #6-350 KCMIL 10.0 13.0 17.5 19.0 5.2 5.2 RX Opening RX Cl. Plate 5 5 Steel Steel 40205-01 40605-025 13.0 19.0 5.2 RX Cl. Plate 7 Steel 40607-025 13.0 19.0 5.2 RX Cl. Plate 7 Steel 40607-02BU Approved for Xcel Energy 200 200 OH OH/UG Approved for Kansas City Power and Light 200 OH #6-350 KCMIL Approved for Alliant Energy (Interstate P&L) 200 OH/UG #6-350 KCMIL Type CQ bypass mechanism is lever-operated, non-jaw clamping. Disconnect sleeves should not be used with these devices. 5 terminal devices are not for use with 3 phase, 4 wire service. Type CQ-5 devices have 5th terminal in the 9 o’clock position. 40605-025 4060X 4020X KNOCKOUTS (inches): 䊎: B: S: AI: RX: 1/4 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗2.750 HUB 0P 12 Commercial/Industrial Service 200 Amp - 5 Jaw - Type CQ Cont. Amp Rating 200A Meter Mounting Equipment, Type HQ, Commercial/Industrial Commercial/Industrial 200 Amp - 4, 5 & 7 Jaw - Type HQ 4, 5 & 7 Terminal for 1 Phase, 3 Wire, Polyphase, 3 or 4 Wire, Wye or Delta Cont. Amp Connectors Dimensions (in.) Hub No. of Enclosure Catalog Rating Service Line W H D Opening Term. Material Number Approved for Mid American Energy Co., Midwest Power (Two Rivers Serv. Cen.) 200 OH #6-350 KCMIL 10.0 17.5 5.2 RX Opening 5 Steel 40005-01 Approved for Ameren, Mid American Energy Co., Midwest Power (Two Rivers Serv. Cen.) 200 OH #6-350 KCMIL 10.0 17.5 5.2 RX Opening 5 Steel 40005-01QG 200 OH #6-350 KCMIL 10.0 17.5 5.2 RX Opening 7 Steel 40007-01QG 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 5 Steel 40405-02QG 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 7 Steel 40407-02QG Approved for Alliant Energy (Interstate P&L), Mid American Energy Co., Midwest Power (Two Rivers Serv. Cen.), Xcel Energy 200 OH #6-350 KCMIL 10.0 17.5 5.2 RX Opening 7 Steel 40007-01 Approved for Xcel Energy 200 OH/UG #6-350 KCMIL 10.0 17.0 5.2 RX Cl. Plate 4 Steel 40404-025 Approved for Ameren, Mid American Energy Co. 200 OH/UG #6-350 KCMIL 10.0 17.0 5.2 RX Cl. Plate 4 Steel 40404-02QG Approved for Mid American Energy Co., Midwest Power (Two Rivers Serv. Cen.), Xcel Energy 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 5 Steel 40405-025 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 7 Steel 40407-025 Approved for Commonwealth Edison (Excelon) 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 5 Steel 40405-02CH 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 7 Steel 40407-02CH Approved for Xcel Energy 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 5 Steel 40405-02CO 200 OH/UG 3/8”-24 Stud 12.8 19.1 5.2 RX Cl Plate 4 Steel 42504-025 200 OH/UG 3/8”-24 Stud 13.0 19.0 5.2 RX Cl Plate 5 Steel 42505-025 Approved for Alliant Energy (Interstate P&L) 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Opening 7 Steel 40407-01NU 200 UG (PED) #6-350 KCMIL 10.9 56.0 6.0 Blank Top 7 Steel 40407P-9WI Approved for Adams Electric Coop 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 7 Steel 40407-0250 Approved for Ameren 200 OH #6-350 KCMIL 10.0 17.5 5.2 RX Opening 4 Steel 40804-01QG 200 OH #6-350 KCMIL 10.0 17.5 5.2 RX Cl. Plate 5 Steel 41005-01F 200 OH/UG #6-350 KCMIL 13.0 19.0 5.2 RX Cl. Plate 5 Steel 9804-8592 200 OH/UG #6-350 KCMIL 20.0 34.0 6.2 HD Cl. Plate 7 Steel 9804-9109 Units are not suitable for use with disconnect sleeves. Bypass mechanism is lever-operated, jaw pressure release with 100% bypass capacity. Devices have 5th terminal in the 6 o’clock position and are not for use with 3 phase 4 wire service. Neutral can be isolated by removing the ground strap. Sockets with “QG” suffix are supplied with 2 ground lugs. Devices have 5th Terminal in the 9 o’clock position and are not for use with 3 phase, 4 wire service. 9804-9142 KNOCKOUTS (inches): 䊎: A: B: S: AC: AF: AG: AI: EE: RX: 13 1/4 1/2 1/2, 3/4 1, 1-1/4, 1-1/2, 2, 2-1/2 1/4, 1/2 1, 1-1/2, 2, 2-1/2, 3 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 2, 2-1/2, 3 쏗2.750 HUB 0P 404/414 410/400 40407-025 9804/9142 Cont. Amp Rating Service Connectors Load Dimensions (in.) W H D Hub Opening No. of Term. Enclosure Material Catalog Number 3/8-24 Stud 3/8-24 Stud 3/8-24 Stud 3/8-24 Stud 13.0 16.0 28.0 5.0 31.0 5.0 HD Cl. Plate HD Cl. Plate 4 4 Steel Steel 47604-02QG 48104-82WI (2) #4-350 KCMIL 12.7 3/8-24 Stud 16.0 56.0 5.0 31.0 6.0 Blank Top HD Cl. Plate 4 4 Steel Steel 47604P-9CH 48104-02CH 5.0 6.0 Blank Top HD Cl. Plate 4 7 Steel Steel 47604P-9WI 44707-02PP 5.0 6.0 HD Cl. Plate HD Cl. Plate 4 7 Steel Steel 48104-02 44707-02 Approved for Commonwealth Edison 320 UG (PED) 3/8-24 Stud 320 OH/UG (SW) 3/8-24 Stud Approved for Alliant Energy (Interstate P&L) 320 UG (PED) (2) #4-350KC (2) #4-350KC 12.7 56.0 320 OH/UG 3/0-800 KCMIL 1/2-20 Stud 20.0 34.0 Approved for Kansas City Power and Light, Mid American Energy Co. 320 OH/UG (SW) 3/8-24 Stud 3/8-24 Stud 16.0 31.0 320 OH/UG 1/2-20 Stud 1/2-20 Stud 20.0 34.0 All units have a lever operated, jaw pressure release bypass mechanism rated at 100%. Disconnect sleeves should not be used with these devices. Some devices do not include lugs, order separately. Includes anti-inversion clip H59676. 5 jaw devices are not for use with 3 phase, 4 wire service. Overhead use only for TNP. KNOCKOUTS (inches): 44707-02FL 47707-01FL 48104-02 44707 4770X 48104 A: B: Z: EE: GG: HH: AC: AE: AG: HD: 1/2 1/2, 3/4 1-1/2, 2, 2-1/2 2, 2-1/2, 3 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 1/4, 1/2 1/4, 1/2, 3/4, 1, 1-1/4 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P 476/485 14 Commercial Residential Approved for Ameren 320 OH/UG 320 OH/UG (SW) Connectors Line 320135 Amp - 4,-54&Jaw 7 Jaw - Type HQ Amp - Ringless 320A Continuous/400A Maximum, Meter Mounting Equipment, Type HQ, Commercial 4, 5 & 7 Terminal for 1 Phase, 3 Wire & Polyphase, 4 Wire Residential / Commercial 200A - 4, 5 & 7 Jaw - Multi-Position - Lever Bypass 200A Multi-Position, Lever Bypass, Meter Mounting Equipment, Residential /Commercial 4, 5 and 7 Terminal for 1 Phase, 3 Wire 404052-023NU 4040X2 404073-023NU 4040X3 4040X4 KNOCKOUTS (inches): 4040X5 B: X: AC: AD: HD: 4040X6 1/2, 3/4 2, 2-1/2, 3, 3-1/2 1/4, 1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗4.281 HUB 0P No. of Cont. Overall Connectors Dimensions (in.) Pos. Amp Ampacity Service Bypass Line Load W H D 200 A/Pos, 1 Phase, 3 Wire, Horizontal Multi-Position Metering, Lever Bypass, Heavy Duty 2 200 250 OH/UG Lever 1/0-500 kcmil #6-350 kcmil 32.8 23.2 6.0 2 200 250 OH/UG Lever 1/0-500 kcmil #6-350 kcmil 32.8 23.2 6.0 3 200 250 OH/UG Lever 1/0-500 kcmil #6-350 kcmil 43.9 23.2 6.0 4 200 300 OH/UG Lever (2) 1/0-500 kcmil #6-350 kcmil 61.0 23.2 6.0 5 200 300 OH/UG Lever (2) 1/0-500 kcmil #6-350 kcmil 72.1 23.2 6.0 6 200 410 OH/UG Lever (2) 1/0-500 kcmil #6-350 kcmil 83.2 23.2 6.0 Large Cl. Plate Large Cl. Plate Large Cl. Plate (2) Lg. Cl. Plates (2) Lg. Cl. Plates (2) Lg. Cl. Plates 4 5 5 5 5 5 404042-01 404052-023NU 404053-023NU 404054-223NU 404055-223NU 404056-223NU 200A/Pos, 3 Phase, 4 Wire, Horizontal Multi-Position Metering, Lever Bypass, Heavy Duty 2 200 250 OH/UG Lever 1/0-500 kcmil #6-350 kcmil 32.8 23.2 3 200 250 OH/UG Lever 1/0-500 kcmil #6-350 kcmil 43.8 23.2 4 200 300 OH/UG Lever (2) 1/0-500 kcmil #6-350 kcmil 61.0 23.2 5 200 300 OH/UG Lever (2) 1/0-500 kcmil #6-350 kcmil 72.1 23.2 6 200 410 OH/UG Lever (2) 1/0-500 kcmil #6-350 kcmil 83.2 23.2 Large Cl. Plate Large Cl. Plate (2) Lge Cl. Plates (2) Lge Cl. Plates (2) Lge Cl. Plates 7 7 7 7 7 404072-023NU 404073-023NU 404074-223NU 404075-223NU 404076-223NU Hubs: Connectors: 5th Terminal: 15 6.0 6.0 6.0 6.0 6.0 Hub Opening Please see accessories on page 23. Extruded aluminum connectors are tin plated and removable. Please see page 21 - 22 for alternate connectors. 5 Terminal sockets have 5th jaw in the 9:00 position. No.of Catalog Term. Number Type PTS Transformer-Rated Meter Mounting Equipment with Test Switch Provision PTS Transformer-Rated 쐍 20A continuous rated 쐍 Ground lug available 쐍 Steel or aluminum construction 쐍 Split or solid cover construction 쐍 OH and UG capabilities 쐍 600V rated 쐍 Spacing for multiple test switch configurations 쐍 Customized test switch and wiring KNOCKOUTS (inches): Consult the factory for other available options such as, but not limited to alternate enclosure and hasp material, kearnaloxed terminals, enclosures with special KO configurations, pre-wired units, test switch specifications and special labeling. Catalog Numbers Ringless - Solid Cover Aluminum Steel 9837-8200 9837-8201 9837-8210 9837-8211 9837-8220 9837-8221 9837-8230 9837-8231 9837-8240 9837-8241 PTS8: 8 Jaw 9837-8400 9837-8401 9837-8410 9837-8411 9837-8420 9837-8421 9837-8430 9837-8431 9837-8440 9837-8441 PTS13: 13 Jaw 9837-8500 9837-8501 9837-8510 9837-8511 9837-8520 9837-8521 9837-8530 9837-8531 9837-8540 9837-8541 Socket Type PTS6: 6 Jaw Ringless - Split Cover Aluminum Steel 9837-8202 9837-8203 9837-8212 9837-8213 9837-8222 9837-8223 9837-8232 9837-8233 9837-8242 9837-8243 9837-8402 9837-8403 9837-8412 9837-8413 9837-8422 9837-8423 9837-8432 9837-8433 9837-8442 9837-8443 9837-8502 9837-8503 9837-8512 9837-8513 9837-8522 9837-8523 9837-8532 9837-8533 9837-8542 9837-8543 Ring Type - Split Cover Aluminum Steel 9837-8204 9837-8205 9837-8214 9837-8215 9837-8224 9837-8225 9837-8234 9837-8235 9837-8244 9837-8245 9837-8404 9837-8405 9837-8414 9837-8415 9837-8424 9837-8425 9837-8434 9837-8435 9837-8444 9837-8445 9837-8504 9837-8505 9837-8514 9837-8515 9837-8524 9837-8525 9837-8534 9837-8535 9837-8544 9837-8545 B: Q: AC: RX: 1/2, 3/4 1, 1-1/4, 1-1/2 1/4, 1/2 쏗2.750 HUB 0P Dimensions (in.) L W D 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 20.0 12.0 4.5 Cont. Amp Rating 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Hub Opening RX Cl. Plate 1" Hub Inst. 1.25" Hub Inst. 1.50" Hub Inst. Blank Top RX Cl. Plate 1" Hub Inst. 1.25" Hub Inst . 1.50" Hub Inst. Blank Top RX Cl. Plate 1" Hub Inst. 1.25" Hub Inst 1.50" Hub Inst. Blank Top Terminal Wire Range Current Potential #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 #4-14 #8-14 GENERAL INFORMATION: Capacity: Application: Enclosures: Terminals: 20 amperes, 600 volts a.c. Transformer-rated applications. Available with or without test switch and pre-wiring. 14-gauge .063 aluminum or 16-gauge galvannealed steel suitable for indoor or outdoor installation. Set screw type . Hubs: Finish: Interchangeable 1”, 1-1/4”, 1-1/2” Aluminum unpainted unless specified. Steel enclosures have gray polyester powder coat finish. Test Switchs: Standard 6 and 10 pole, 480-volt rated switches are available from stock. Special switches available upon request. 16 Commercial/Industrial Common Features 400A/480A Meter Mounting Equipment, Type K4, Residential Residential 400/480 Amp - 4 Jaw - Ringless 4 Terminal for 1 Phase, 3 Wire Cont./Max Amp Rating Service Approved for Ameren 400 OH/UG 480 OH/UG Connectors Line Connectors Load Dimensions (in.) W H D Hub Opening 1/2-20 Stud 1/2-20 Stud 1/2-20 Stud 1/2-20 Stud 18.0 20.3 36.0 43.0 6.0 6.2 1/2-20 Stud 18.0 36.0 6.0 Approved for Kansas City Power and Light 480 OH/UG 1/2-20 Stud No. of Terms Enclosure Material Catalog Number HD Cl. Plate 4 (2) HD Cl. Plates 5 Steel Steel 9810-8523 9817-9404 HD Cl. Plate Steel 9817-9564 7 Optional Manual Bypass H56495 available, normally for utility use only - 2 required. Residential Type K-4 Overhead Parallel Conductor 2 - H58853 2 - H56425 1 - H56732 Overhead Single Conductor Line Parallel Conductor Load 2 - H58852 2 - H56425 1 - H56476 1 - H56732 Underground Parallel Conductor 2 - H58853 2 - H56732 1 - H56426 Underground Single Conductor Line Parallel Conductor Load 2 - H58852 2 - H56425 1 - H56476 1 - H56732 Overhead Single Conductor 4 - H58852 2 - H56476 9810-8502 KNOCKOUTS (inches): B: GG: HH: HD: 17 1/2, 3/4 2-1/2, 3, 3-1/2 2-1/2, 3, 3-1/2, 4 쏗4.281 HUB 0P Underground 4 - H58852 2 - H56476 7 Terminal & 7 Terminal Side-Wired, Polyphase, 3 or 4 Wire, Wye or Delta Service Connectors Line Approved for Ameren 480 OH/UG 1/2-20 Stud Approved for Kansas City Power and Light 480 OH/UG 1/2-20 Stud Connectors Load Dimensions (in.) W H D Hub Opening 1/2-20 Stud 20.0 43.0 6.2 (2) HD Cl. Plates 7 Steel 9817-9504 1/2-20 Stud 20.0 43.0 6.2 (2) HD Cl. Plates 7 Steel 9817-9564 All units are UL listed. Optional Manual Bypass H58888 available, normally for utility use only (3 required). 9817-9504 No. of Terms Enclosure Catalog Material Number 400/480 135 Amp Amp- 4- 7Jaw Jaw- Ringless - Ringless Cont./Max Amp Rating Residential Type K-7 Overhead Single Conductor 8 - H56476 Overhead Single and Triple Load Feed 4 - H56476 4 - H68752-1 Overhead Parallel Conductor 8 - H56732 Underground Single Conductor 3 - H58852 5 - H56476 Underground Single Conductor Line Triple Conductor Load 3 - H58852 1 - H56476 4 - H67852-1 Underground Parallel Conductor 3 - H58853 5 - H56732 KNOCKOUTS (inches): B: HH: HD: 1/2, 3/4 2-1/2, 3, 3-1/2, 4 쏗4.281 HUB 0P 18 Residential Residential/Commercial/Industrial 400A/480A Meter Mounting Equipment, Type K-7, Residential/Commercial/Industrial Residential 100/200 Amp - 4 & 5 Jaw - Ringless 100A/200A Meter Mounting Equipment, Type AP, Pedestal, Meter Main, Residential, Horn Bypass 4 & 5 Terminal for 1 Phase, 3 Wire Connectors Connectors Rating Service Line Load Approved for Commonwealth Edison 100/200 UG 4/0 #6-350 kcmil 100/200 UG 4/0 see breaker rating 100/200 UG 4/0 #4-1/0 100/200 100/200 100/200 UG UG UG 4/0 4/0 4/0 Dimensions (inches) W H D Main Breaker Bypass Catalog Number 8.0 8.0 8.0 64.5 64.5 64.5 4.5 4.5 4.5 None 200A provision 100A inst. Horn Horn Horn UAP317-PPCH UAPB317-PPCH UAPC311-PPCH #2-1/0 8.0 4/0AL, 2/0 CU 8.0 300 KCMIL AL, 4/0 CU 8.0 64.5 64.5 64.5 4.5 4.5 4.5 125A inst. 150A inst. 200A inst. Horn Horn Horn UAPC318-PPCH UAPC314-PPCH UAPC317-PPCH Pedestals are U.L. listed and CECHA approved. 5th terminal kit for field installation: S659-0121. Build to order. Please contact sales representative for lead time. Breaker Table Amps 100 125 150 200 Circuit Breaker L2100, Q2100 L2125, Q2125 LN2150, QN2150B LN2200, QN2200B UAPB317-PPCH has a provision for a 100-200 amp circuit breaker. See breaker table for details. Breaker factory installed. See breaker table for replacement circuit breakers Accessories Item Bottom plate for free standing installation Extension Kit Catalog Number 5007714 5007718 KNOCKOUTS (inches): UAPB317-PPCH (for use with main breaker) 19 UAP317-PPCH A: R: VV: 1/2 1, 1-1/4, 1-1/2, 2 2 Rating Type Service Connectors Line Connectors Load Dimensions (in.) W H D Main Breaker Bypass Catalog Number Approved for Commonwealth Edison 200 HQ-5P UG #6-350 kcmil #6-350 kcmil 11 56 6 none Lever 40405P-9CH 200 HQ-7P UG #6-350 kcmil #6-350 kcmil 11 56 6 none Lever 40407P-9CH 320 HQ-4SP UG (2)#6-350 kcmil (2)#6-350 kcmil 13 56 5 none Lever 47604P-9CH 320 HQ-4SPB UG (2)#6-350 kcmil see breaker rating 13 56 5 (2)200A breakers Lever 47604PB-9CH Pedestals are U.L. listed and CECHA approved. Bypass mechanism is lever-operated, jaw pressure release with 100% bypass capacity. These devices are not rated for use with disconnect sleeves. HQ-5 for 3 wire service only. Includes center phase disconnect. 5th terminal in 9 o’clock position. (2) Siemens type QJ breakers, factory installed. Available 2004. Accessories Item Extension kit for 200 Amp Extension kit for 320 Amp Catalog Number 5007720 5007719 KNOCKOUTS (inches): S: 47604P-9CH 47604PB-9CH 1, 1-1/4, 1-1/2, 2, 2-1/2 40407P-9CH 20 200/320 Amp - 4, 5 & 7 Jaw - Type HQ 4, 5 & 7 Terminal for 1 Phase, 3 Wire Residential/Commercial/Industrial 200A/320A Continuous, Pedestal Type, Meter Mounting Equipment, Type HQ, 320A Meter Main, Residential/Commercial/Industrial 100A/200A Meter Mounting Equipment, Meter Main, Residential Residential 100/200 Amp - Meter Mains 4 & 5 Terminal for 1 Phase, 3 Wire Connectors Rating Service Line Load Dimensions (in.) Hub W H D Opening Main Breaker No. Cover Term. Bypass Style Catalog Number 125 150 200 OH/UG OH/UG OH/UG #6-250 KCMIL #2-1/0 CU, 2/0 AL 18.5 17.0 5.1 #6-250 KCMIL #1-300 KCMIL 18.5 17.0 5.1 #6-250 KCMIL #1-300 KCMIL 18.5 17.0 5.1 RX Cl. Plate 125A inst. RX Cl. Plate 150A inst. RX Cl. Plate 200A inst. 5 5 5 Horn Horn Horn 100 OH #14-2/0 8.0 28.5 4.5 RX Opening 125A Prov. 4 Horn Ringless LGMM0202B1125RJBX Ringless LGMM0202B1150RJBX Ringless LGMM0202B1200RJBX Ringless UAB111-0PCH 200 OH #6-350 KCMIL see breaker rating 8.0 28.5 4.5 RX Opening 200A inst. 4 Horn Ringless UAB317-0PCH 200 OH/UG #6-350 KCMIL see breaker rating 11.6 28.0 5.2 RX Cl. Plate 150-200A Prov. 4 None Ringless UAB417-XPG 200 UG -SW #6-350 KCMIL see breaker rating 13.1 25.1 5.2 Blank Top None Ringless UAB877-PG 150 OH/UG #6-250 KCMIL #1-300 KCMIL 16.0 17.0 5.1 RX Cl. Plate 150A inst. 4 None Ring LGMM0202B1150 200 OH/UG #6-250 KCMIL #1-300 KCMIL 16.0 17.0 5.1 RX Cl. Plate 200A inst. 4 None Ring LGMM0202B1200 #6-350 KCMIL All units are UL listed. 5th terminal factory installed 5th terminal for field installation: H659-0121. 150-200A Prov. 4 UAB111-0PCH has a provision for a 125 amp max. circuit breaker. See breaker table for details. Breaker factory installed. See breaker table for replacement circuit breakers. 䊊⯗ 䊎: A: C: S: Z: DD: RX: Breaker Table Amps 100 125 150 200 UAB317 200 KNOCKOUTS (inches): Circuit Breaker Q2100 Q2125 QN2150 QN2200 5/16 on UAB4, 5/16,1/2 on UAB8 1/4 1/2 1/2, 3/4, 1 1, 1-1/4, 1-1/2, 2, 2-1/2 1-1/2, 2, 2-1/2 1-1/4, 1-1/2, 2, 2-1/2, 3 쏗2.750 HUB 0P QJ22B200 UAB1/UAB3 UAB317-0PCH 21 UAB417-XPG UAB877-PG LGMM0202B1200 200A/400A Meter Mounting Equipment, Meter Main, Residential 4 & 5 Terminal for 1 Phase, 3 Wire Hub Opening Main Breaker No. Term. Bypass Cover Style Catalog Number 200 200 200 OH/UG OH/UG OH/UG 30.0 32.0 27.0 14.0 14.0 14.0 5.0 5.0 5.0 RX Cl. Plate RX Cl. Plate RX Cl. Plate 200A inst. 200A inst None 4 4 4 None None None Ringless Ringless Ringless LG0408B1200RT LG0816B1200RCT LG0606L1200R 200 400 400 OH/UG OH OH 27.0 29.0 29.0 14.0 27.0 27.0 5.0 6.0 6.0 RX Cl. Plate HD Cl. Plate HD Cl. Plate None 4 None 4 200A inst. 4 space for one more 200A main None Lever Lever Ringless Ringless Ringless LG0606L1200RA* LG0404L1400RLM LG0816B1400RLT * Aluminum enclosure. LG0408B1200RT LG0816B1200RCT LG0606L1200R 4 space, 8 circuit feed thru lugs 8 space, 16 circuit feed thru lugs 12 space, 6 circuit LG0606L1200RA 2 or 4 pole breakers only LG0404L1400RLM Accepts 2 main breakers 60-200A each LG0816B1400RLT 8 space, 10 circuit feed thru lugs 22 Residential Residential Dimensions (in.) W H D 200/400 Amp -- 4Meter 135 Amp Jaw -Mains Ringless Rating Service Circuit Breakers Circuit Breakers Features 쐽 Plug in 쐽 UL listed for use with Landis & Gyr branded meter combinations 쐽 1” Frame 23 Description Amps Catalog No. 1-Pole 120V 15 L115 1-Pole 120V 20 L120 2-Pole 120/240V 20 L220 2-Pole 120/240V 30 L230 2-Pole 120/240V 40 L240 2-Pole 120/240V 50 L250 2-Pole 120/240V 60 L260 2-Pole 120/240V 100 L2100 2-Pole 120/240V 125 L2125 4-Pole 120/240V 150 LN2150R 4-Pole 120/240V 200 LN2200R Accessories Catalog No. Single Pole Padlocking Device ECPLD1 Double Pole Padlocking Device ECPLD2 4-Pole Padlocking Device ECPQLN3 Handle Blocking Device (1 & 2 Pole) ECQL1 Single Pole Double Pole 4-Pole Air Conditioning Disconnects and Enclosed Receptacles Fused햲 and Non-Fused 쐽 쐽 쐽 쐽 쐽 쐽 쐽 쐽 Rugged Durability 30-60 amperes 240 volts A.C. Padlock provisions Horsepower rated 10,000 A.I.C. New models available with internal GFCI receptacle Removable Door Ample Wiring Space 쐽 Noryl약 thermoplastic and powder coated G90 steel enclosures are corrosion resistant and extremely durable giving long maintenance free service 쐽 Copper conductors 쐽 Raised mounting embosses Steel AC Disconnects Ampere Rating Disconnect Type Catalog No. Horse Power Rating Dimensions (inches) H W D 30 Fused Pullout LF2030 3 7.3 5.0 2..1 60 Fused Pullout LF2060 10 8.0 5.0 2.1 60 Non-Fused Pullout LN2060 10 7.3 5.0 2.1 60 Non-Automatic Switch LNAS2060 10 7.3 5.0 2.1 Dimensions (inches) H W D Plastic AC Disconnects Ampere Rating Disconnect Type Catalog No. Horse Power Rating 30 Fused Pullout LF2030PL 3 8.0 5.3 3.1 60 Fused Pullout LF2060PL 10 8.0 5.3 3.1 60 Non-Fused Pullout LN2060PL 10 7.3 5.0 2.1 60 Non-Fused Pullout LN2060PLX 10 8.0 6.0 5.8 Steel AC Disconnects with 15 Amp GFCI Receptacle Ampere Disconnect Rating Type Catalog No. Horse Power Rating Dimensions (inches) H W D 30 Fused Pullout LF2030GFCI 3 9.0 6.1 5.1 60 Fused Pullout LF2060GFCI 10 9.0 6.1 5.1 60 Non-Fused Pullout LN2060GFCI 10 7.1 5.8 5.1 60 Non-Automatic Switch LNAS2060GFCI 10 7.1 5.8 5.1 Enclosed Receptacles Ampere Rating Disconnect Type Catalog No. Receptacle Type Dimensions (inches) H W D 60 N/A LGP1S 14-50R 7.1 5.8 5.2 30 N/A LGP3S TT30R 7.1 5.8 5.2 Wire Range Table Copper Aluminum Connector Solid Stranded Solid Line #14-8 #14-3 #12-8 Stranded #12-3 Load #14-8 #14-3 #12-8 #12-3 Neutral #12-8 #12-2 #12-8 #12-2 Equip. Grnd. #12-8 #12-2 #12-8 #12-2 24 A CResidential Disconnects Flexibility Non-Fused 135Fused Amp -and 4 Jaw - Ringless Features Spa Panel Spa Panel 50 Amp and 60 Amp For use as Spa/Hot Tub service disconnect 2-Pole GFCI Breaker 50A 60A Dimensions (inches) H W D 12.3 6.0 4.5 12.3 6.0 4.5 Catalog Number LGSPA50 LGSPA60 Dead Front Enclosure Hub Cover Plate included Features and Benefits 쐽 UL Listed 쐽 Factory installed, 2-pole 50A or 60A GFCI breaker for 240V ground fault protection 쐽 NEMA Type 3R outdoor enclosure 쐽 2 extra spaces (4 circuits maximum) for additional circuit breakers 쐽 125 Amp rated interior 12-1/4” 쐽 Factory installed 5 position ground bar 쐽 Closure plate included 쐽 Compact enclosure size 쐽 Convenient standard package of 1 쐽 Uses reliable Siemens circuit breakers 6” 25 Connector Lugs H55890-1 #6-350 KCMIL 3/8” Stud H56734 #6-250 KCMIL 1/2” Stud H37892 #4-500 KCMIL 1/2” Stud H57606-K #6-350 KCMIL 3/8” Stud H56476 #3/0-800 KCMIL 1/2” Stud H60162 (1) #4-600 KCMIL 1/2” Stud H61300 (2) 1/0-250 KCMIL 1/2” Stud H58022 (2) #6-250 KCMIL 3/8” Stud H56732 (2) #4-350 KCMIL 1/2” Stud H56732-1 (2) #4-350 KCMIL 1/2” Stud H56732-2 (2) #4-350 KCMIL 3/8” Stud H56732-M (2) #4-500 KCMIL 1/2” Stud H68752-1 (3) #6-250 KCMIL 1/2” Stud H56426 (4) #6-350 KCMIL 1/2” Stud H56477 3/0-800 KCMIL 1/2” Stud H56425 (2) #6-350 KCMIL 1/2” Stud H56425-M (2) #4-500 KCMIL 1/2” Stud H58852 3/0-800 KCMIL 1/2” Stud H56733 3/0-800 KCMIL 1/2” Stud H56427 (2) #6-350 KCMIL 1/2” Stud H56427-M (2) #4-500 KCMIL 1/2” Stud H58853 (2) #6-350 KCMIL 1/2” Stud H59299-1 1/2” Stud 26 Residential Connector Lugs 3/8” Stud 135 Amp - 4 Jaw - Ringless H55890 #6-350 KCMIL Connector Lugs Lug Extender Connector Lugs Pressure type lugs for Landis & Gyr’s stud type meter mounting devices are made of 6061-T6 aluminum to provide high strength and high conductivity. All lugs are tin-plated to ensure low contact resistance and to reduce corrosion. Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action with the lug. All Landis & Gyr lugs are listed with Underwriters Laboratories. Pressure Lug Connectors For Meter Mounting Devices Device Type HQ-4S HQ-5 S HQ-7S HQ-4D HQ-5DM HQ-7D HQ-7DF K-4,5,7 K-4,5,7 K-4 K-4,5,7 K-4,5,7 K-5,7 K-4,5,7 K-5,7 K-5,7 K-5,7 K-5,7 K-4,5,7 K-4,5,7 (Grd.) K-4,5,7 K-4,5,7 K-4,5,7 K-4 extender Anti-Rotation Feature No No No No No Yes No No No No Yes Yes Yes Yes No Yes No Yes Yes No Yes Yes Yes Yes Conductor Size #6-350 MCM #6-350 MCM #6-350 MCM (2) #6-250 MCM #4-500 MCM (1) #4-600 MCM or (2) #1/0-250 MCM (2) #6-350 MCM (2) #4-500 MCM (4) #6-350 MCM (2) #6-350 MCM (2) #2-500 MCM #3/0-800 MCM #3/0-800 MCM (2) #4-500 MCM (2) #4-350 MCM (2) #4-350 MCM (2) #4-500 MCM #3/0-800 MCM #6-250 MCM #3/0-800 MCM (2) #6-350 MCM (3) #6-250 MCM 1/2-20 x 1-7/8” Stud Stud Opening Pressure Screw Head Dimensions* (inches) L W H Landis & Gyr Catalog Number 13/32” 13/32” 13/32” 13/32” 9/16” 9/16” 9/16” Hex 5/16” Allen 3/8” Allen 5/16” Allen 3/8” Allen 1/2” Allen 2-1/4 2-1/4 2-1/4 2-3/16 2-13/16 2-13/16 1-1/8 1-1/8 1-1/8 1-5/8 1-1/2 1-3/8 1-1/4 1-1/4 1-1/4 1-3/16 1-9/16 1-13/16 H55890 H55890-1 H57606-K H58022 H37892 H60162 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 9/16” 1/2” Allen 5/16” Allen 3/8” Allen 5/16” Allen 5/16” Allen 3/8” Allen 1/2” Allen 1/2” Allen 3/8” Allen 5/16” Allen 5/16” Allen 3/8” Allen 1/2” Allen 5/16” Allen 1/2” Allen 5/16” Allen 5/16” Allen None 2-13/16 2-7/8 2-13/16 2-7/8 4-15/16 4-1/4 3-1/4 3-1/4 2-13/16 2-7/8 2-7/8 2-13/16 4-3/16 2-9/16 3-15/16 3-15/16 2-7/8 4-1/4 1-3/8 1-13/16 1-57/64 1-1/4 2-1/16 1-9/16 3-15/16 1-1/4 1-1/8 2-1/16 1-1/8 1-13/16 1-5/16 1-13/16 1-5/16 1-13/16 2-5/32 1-9/16 1-59/64 1-1/4 1-59/64 1-1/4 2-5/32 1-13/16 1-3/4 2-3/8 1-9/32 1-3/16 1-3/4 1-13/16 1-1/8 1-1/2 2-31/64 1-7/16 1-1/4 2-3/8 H61300 H56425 H56425-M H56426 H56427 H56427-M H56476 H56477 H56490 H56732 H56732-1 H56732-M H56733 H56734 H58852 H58853 H68752-1 H59299-1 Lug Extender Device Type Stud Opening Stud Size Dimensions (inches) W H D Landis & Gyr Catalog Number K-4 9/16” 1/2-20 x 1-7/8” 4-1/4 H59299-1** 1-1/4 2-3/8 H * Dimensions do not include height of pressure screw with conductor installed. ** Includes nut and washer assembly and washer. 27 W L Accessories Removable Hub Kits RX Type Hubs Small 1 H38596-2 1-1/4 1-1/2 2 H38597-2 H38598-2 H38599-2 2-1/2 Cover Plate - Steel H38600-2 H38595-1 Cover Plate - Aluminum HD Type Hubs Large 3 3-1/2 4 Cover Plate - Steel Cover Plate - Aluminum H38595-2 H56856-2 H56857-2 H56858-2 H56933 H56933-1 Description Catalog Number Stainless Steel H54602 Residential Cover Plate Conduit Size (inches) Accessories 135 Amp - 4 Jaw - Ringless Removable Hub Sealing Rings Catalog Number Snap Type Stainless Steel Screw Type 9738-8001* *Requires 9738-8003 Locking Clip Accessories Catalog Number Description Catalog Number Insulated 5th Terminal Kit Type AS, AT only H659-0120 HQ Isolated Neutral Kit H64685-1* Grounded 5th Terminal Kit Type AS, AT only H659-0121 Description *Includes Neutral and Isolation Block Neutral Isolation Kit for HQ HQ 5th Terminal Kit - w/lead H35815-3 HQ 5th Terminal Kit - 9:00 H35815-2 Large to Small Adaptor Steel Large to Small Adaptor Aluminum H9747-1113 H9747-1112 H64690-1* *Isolates Existing Neutral Black Plastic Meter Opening Cover Clear Plastic Meter H39968 H659-0162 Opening Cover (with plug-in feet) Insulated Jumper H36479* * For up to 200A sockets only. 28 Repair Parts Terms Of Sale Terms of Sale and Device Applications Repair Parts Catalog Number Block Assembly Connector Screw Assembly Neutral Screw Assembly UAT111-0G UAT314-0G UAT417-XG All 200A Gang Sockets 5005800H 5015830-2 5015830-2 1012013 (Screw Only) 200007-1 200007-1 (Load Side Only) 200008-1 1012013 (Screw Only) 200009-1 200009-1 200009-1 Transportation Charges: Prices listed are F.O.B. factory with freight prepaid and allowed on all shipments of orders of $1,000 net or more for single shipments to one location. Minimum Billing: $400 net plus transportation charges. Cancellation: Orders accepted by the factory can be cancelled only with the factory’s consent and upon payment to the seller of reasonable charges incurred by the seller which will indemnify the seller against loss. Returns: Goods may not be returned to Landis & Gyr without written authorization from the factory. A minimum 20% restocking charge will be applicable on all returned goods. Credit will be given only for current production items in unopened cartons. All transportation charges paid by Landis & Gyr will be deducted from such credit. Terms: Standard/Stock Products: 2% 10th net 25th for invoices dated the 1st through the 15th of the month. 2% 25th net 10th for invoices dated the 16th through the 31st of the month. Meter Mounting Device Applications Electrical Service Service Type 1-Phase Self-contained, 3 wire 3-Phase 3-Wire 3-Phase 4-Wire Meter Form 2S 2S 2SE Socket Type 4 jaw 100A 4 jaw 200A 4 jaw 320A Standard Socket Catalog Number UAT111 UAT317, UAT417,HQ-4 HQ-4ST, HQ-4D Self-contained, bolt-in Transformer-rated, 2 wire Transformer-rated, 3 wire 2K 3S 4S 12S K-4 400/480A 6 jaw 20A 6 jaw 20A 5 jaw 100A K-4, K-4UT HQ-6T, HQ-6TS, PTS-6 HQ-6T, HQ-6TS HQ-5 Self-contained 12S 12SE 5 jaw 200A 5 jaw 320A HQ-5 HQ-5ST, HQ-5D Self-contained, bolt-in Transformer-rated Self-contained 12K 5S 14S 15S 14K K-5 480/600A 8 jaw 20A 7 jaw 100/200/320A K-5 HQ-8T, HQ-8TS, PTS-8 CQ-7, HQ-7 Self-contained, bolt-in 15K 16K K-7 480/600A K-7, K-7T 13 jaw 20A HQ-13T, HQ-13TS, PTS-13 Wye Transformer-rated or Delta 29 6S 8S 9S Notes: 30 Notes: 31 Notes: 32 Landis & Gyr Meter Mounting Devices Siemens Industry, Inc. Building Technologies Division 5400 Triangle Parkway Norcross, GA 30092 www.landisandgyr.com Subject to change without prior notice Order No.: RPSA-LG027-1009 All rights reserved Printed in USA © 2009 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-702 Create Date : 2009:11:03 08:13:54-05:00 Modify Date : 2009:11:03 09:19:30-05:00 Metadata Date : 2009:11:03 09:19:30-05:00 Producer : Acrobat Distiller 8.0.0 (Windows) Format : application/pdf Title : untitled Document ID : uuid:5aeefd7a-be75-47e1-b056-a19a9ddd7543 Instance ID : uuid:b85dcebc-ba7e-4900-9438-96a268b33800 Has XFA : No Page Count : 33EXIF Metadata provided by EXIF.tools