ENR Dead Front Interlocked
Circuit Breaking Receptacles
ENP Plugs General Purpose
ArkɀGard® 2; Factory Sealed

COLOR: CMYK

TCP: 15001

Cl. I, Div. 1 & 2, Groups B†,C,D
Cl. II, Div. 1 & 2, Groups F,G
Cl. III
NEMA 3,7BCD,9FG,12

Typedriver Name: TS name

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

csm no.: 100

2P

Application:
ENR receptacles and ENP plugs are used:
ɀ with portable electrical equipment such as
compressors, tools, lighting systems, and
similar devices
ɀ in areas made hazardous by the presence
of flammable vapors and gases or
combustible dusts
ɀ wherever portable electrical equipment is
likely to be transferred from hazardous to
nonhazardous areas
ɀ in damp and corrosive areas
ɀ when power requirements do not exceed
20 amperes
ɀ where general purpose application is
required

Features:

ɀ ArkȿGard 2 receptacle incorporates three
spring-loaded slide keys that prevent the
receptacle face plate from being rotated until
the ENP plug is fully inserted into the
receptacle. To make the connection, the ENP
plug is fully inserted; and the receptacle face
moved inward by pushing the plug forward
(Fig. 1). The plug is then rotated, (Fig. 2),
closing the circuit. As rotation begins, the
plug becomes locked in the receptacle and
cannot be accidentally disengaged. In
making or breaking the circuit, any resulting
electrical arc is confined in the factory-sealed
chamber.
ɀ Factory-sealed chamber encloses the
potential arcing components between two
explosion-proof threaded joints. These
threads are specially coated to guarantee
freedom of movement, which ensures on-off
action. No additional seals are required.
ɀ One piece molded gasket seals cover plate
and ENP plug when plug is inserted,
providing full environmental protection at the
receptacle face.
ɀ Top-hinged cover design with 45°
downward angle provides superior protection
in damp, wet, and dirty locations.
ɀ Molded-in contact design provides superior
interior contact reliability.
ɀ ENP plugs can be used in nonhazardous
areas with standard U-ground NEMA/EEMAC
configuration 5 and 6 receptacles, eliminating
the need for two separately equipped
portable units of the same type. The ENR
receptacle will not accept standard NEMA/
EEMAC configuration plugs.
ɀ ENP plug handle body is designed with an
internal cord strain relief mechanism and a
cable sealing grommet which will accept
various cable diameters.
ɀ Field assembly is accomplished with
standard tools.
ɀ Use standard EDS back boxes.

Figure 2

Figure 1

Grounding:
ɀ NEC Article 501 and CEC Section 18
requires that metal frames or exposed noncurrent-carrying metal parts of portable
devices used in hazardous locations be
grounded through an extra conductor in the
portable cord. ENR receptacles and ENP
plugs are provided with an extra grounding
pole.

Standard Materials:
ɀ Receptacle housing, spring door and plug
body – die cast copper-free aluminum
ɀ Interiors: receptacle – Krydon® fiberglassreinforced polyester material; plugs – nylon
100
ɀ Contacts: receptacle blade – brass;
receptacle switch – silver; plug – brass
ɀ Receptacle cover hinge pin and spring –
stainless steel
ɀ Receptacle gasket – neoprene
ɀ Plug bushing – neoprene

Standard Finishes:
ɀ Copper-free aluminum – aluminum acrylic
paint
ɀ Brass – natural

Electrical Rating Ranges:
ɀ Receptacles – 20 amperes; 125 vac and
250 vac, 50-400 hertz
ɀ Plugs – 15 amperes; 125 vac and 250 vac,
50-400 hertz
20 amperes; 125 vac and 250 vac,
50-400 hertz

Certifications and
Compliances:
ɀ NEC:
Class I, Division 1 and 2, Groups B†,C,D
Class II, Division 1 and 2, Groups F,G
Class III
ɀ ANSI/UL Standard 1010
ɀ NEMA/EEMAC 3,7BCD,9FG
ɀ CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Group G
Class III
CAUTION: To reduce the risk of ignition of
hazardous atmospheres, do not use plugs or
receptacles in Class II, Group F locations that
contain electrically conductive dusts.

Dimensions

† Single gang receptacles purchased as a complete
assembly with EDS back box are suitable for Class I, Group
B usage. Two gang receptacles can be modified for Class I,
Group B usage. Add the letter B to Cat. No. Example:
ENRB22201. Seals must be installed within 11⁄2⍯ of each
conduit opening. Receptacle units only (ie. ENR5201) are not
suitable for Class I, Group B.
a=31⁄2 for single gang; 79⁄16 for two gang.
US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1007))
CH0 0 2 P - 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1007

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1008-2 Name: 2P-1008

2P

DATE: JAN 19 2006

Time: 6:08:31 PM Operator: RB

ENR Dead Front Interlocked
Circuit Breaking Receptacles
ENP Plugs General Purpose (For US NEC
Applications); ArkȿGard® 2; Factory Sealed

ENR single gang
dead end assembly

Receptacle
Rating

Description
Dead End

ENR single gang
dead end assembly with
spring door open

Hub
Size
1⁄2
3⁄4
1

Single Gang
Receptacle
Assembly
Cat. # ‡
ENR11201
ENR21201
ENR31201

COLOR: CMYK

20 amp,
125 volt

ENR receptacle only,
with spring door open
Receptacle
Unit Only
Cat. #

ENP plug

15 Amp
NEMA Plug
Config. Cat. #

NEMA
Config.

ENP5151

Through Feed

3⁄4

1
1⁄2

Dead End

3⁄4

1

ENRC12201
ENRC22201
ENRC32201

ENR11202
ENR21202
ENR31202

ENR12202
ENR22202
ENR32202

20 amp,
250 volt

5-15P

ENP6152

ENR6202
Through Feed

3⁄4

1

ENRC11202
ENRC21202
ENRC31202

NEMA
Config.

5-20P

ENP6202

6-20R
1⁄2

20 Amp
Plug
Cat. #

ENP5201

5-20R
ENRC11201
ENRC21201
ENRC31201

Explosionproof
Raintight
Wet Locations
Dust-Ignitionproof

ENR two gang
dead end assembly with
one spring door open

ENR5201
1⁄2

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1 & 2, Groups F,G
Cl. III
NEMA 3,7BCD,9FG,12

ENR two gang
dead end assembly

Two Gang
Receptacle
Assmebly
Cat. # ‡
ENR12201
ENR22201
ENR32201

TCP: 15001

6-15P

6-20P

ENRC12202
ENRC22202
ENRC32202
* Single gang receptacles purchased as a complete
assembly with EDS back box are suitable for Class I, Group
B usage. Two gang receptacles can be modified for Class I,
Group B usage. Add the letter B to Cat. No. Example:
ENRB22201. Seals must be installed within 11⁄2⍯ of each
conduit opening. Receptacle units only (ie. ENR5201) are not
suitable for Class I, Group B.
‡ With Feraloy

1008

STIBOINFO((CRH:66008com:2P:1008))
CH0 0 2 P - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

®

Iron Alloy EDS, EDSC back boxes.

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1009-1 Name: 2P-1009

DATE: JAN 19 2006

Time: 6:08:33 PM Operator: RB

ENR Dead Front Interlocked
Circuit Breaking Receptacles
ENP Plugs; General Purpose (For CEC
Applications) ArkȿGard® 2; Factory Sealed

ENR single gang
dead end assembly

Receptacle
Rating

Description
Dead End

TCP: 15001

Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1 & 2, Group G
Cl. III
EFC 3,7BCD,9G,12

ENR single gang
dead end assembly with
spring door open

Hub
Size
1⁄2
3⁄4
1

COLOR: CMYK

Single Gang
Receptacle
Assembly
Cat. # ‡
ENR11151
ENR21151
ENR31151

Explosionproof
Raintight
Wet Locations
Dust-Ignitionproof

ENR two gang
dead end assembly
Two Gang
Receptacle
Assembly
Cat. # ‡
ENR12151
ENR22151
ENR32151

15 amp,
125 volt

Typedriver Name: TS name

Receptacle
Unit Only
Cat. #

EEMAC
Config.

Plug
Cat. #

Through Feed

3⁄4

1
1⁄2

Dead End

3⁄4

1

ENRC12151
ENRC22151
ENRC32151

ENR11152
ENR21152
ENR31152

ENR12152
ENR22152
ENR32152

15 amp,
250 volt

5-15P

ENP6152

ENR6152
6-15A
1⁄2

Through Feed

3⁄4

1
1⁄2

Dead End

3⁄4

1

ENRC11152
ENRC21152
ENRC31152

ENRC12152
ENRC22152
ENRC32152

ENR11201
ENR21201
ENR31201

ENR12201
ENR22201
ENR32201

20 amp,
125 volt

6-15P

ENP5201

ENR5201
5-20R
1⁄2

Through Feed

3⁄4

1
1⁄2

Dead End

3⁄4

1

ENRC11201
ENRC21201
ENRC31201

ENRC12201
ENRC22201
ENRC32201

ENR11202
ENR21202
ENR31202

ENR12202
ENR22202
ENR32202

20 amp,
250 volt

6-20R
Through Feed

3⁄4

1

ENRC11202
ENRC21202
ENRC31202

5-20P

ENP6202

ENR6202
1⁄2

EEMAC
Config.

ENP5151
5-15R

ENRC11151
ENRC21151
ENRC31151

2P

ENR two gang
dead end assembly with
one spring door open

ENR5151
1⁄2

csm no.: 100

6-20P

ENRC12202
ENRC22202
ENRC32202

* Single gang receptacle units can be modified for Class 1,
Group B usage. Add suffix B to the Cat. No. Example:
ENRB11201. Seals must be installed immediately adjacent to
each conduit opening.
‡ 15A With Copper-free aluminum EDS, EDSC back boxes.
20A with Feraloy® iron alloy EDS, EDSC back boxes

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1009))
CH0 0 2 P - 9

CAN: 1-800-265-0502

©

Copyright 2006 Cooper Crouse-Hinds

1009

Zoom: 100



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Modify Date                     : 2006:01:23 17:13:23Z
Create Date                     : 2006:01:23 17:13:23Z
Metadata Date                   : 2006:01:23 17:13:23Z
Format                          : application/pdf
Document ID                     : uuid:3a93c4f8-a1bd-42df-af32-045e11dd2c92
Instance ID                     : uuid:6f1f6601-c9eb-4b60-947b-e22987782ddc
Producer                        : Acrobat Distiller 6.0.1 for Macintosh
Page Count                      : 3
Creator                         : Adobe Acrobat 7.0
EXIF Metadata provided by EXIF.tools

Navigation menu