Section C
CONTORLS INDEX

D2C Series
DuraTech Control Stations ...................2 - 5

D2C Series
Dimensional Data ................................6 - 7

XCS/XS/SWB Series
Control Stations
External Sealing Required................18 - 25

SWB Series
Device Boxes ..........................................19
SWB Series
Conduit Opening Data ............................20

CS Series
CONSPEC Control Stations ...................8 - 10

CS Series
Dimensional Data
Catalog Logic .........................................11

XCS Series
Cover Assemblies Control Stations ......21 - 25

XCS Series
Blank Covers...........................................26

FXCS/XCS Series
Accessories, Replacement Parts..........26 - 27

FXCS Series
Seal-X Factory
Sealed Control Stations....................12 - 17

FXB Series
Seal-X Splice Boxes ................................13

FXCS Series
Seal-X Factory Sealed
Cover Assemblies ............................14 - 17

XS Series
Tumbler Switch........................................28

XAL/XAS Series
Fire Alarm Stations ..................................29

C2

D2C SERIES • CONTROLS
C O N T R O L S TAT I O N S - N O N - M E TA L L I C

Class I, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups IIC, llB, llA
NEMA 3, 4, 4X, 7 (Div.2)

Factory Sealed
Contact Block
1N.O./1N.C.

F E AT U R E S - S P E C I F I C AT I O N S

PRODUCT LINE OVERVIEW
ASSEMBLIES

Applications
Hazardous and corrosive environments
such as refineries, chemical plants, water
treatment and bio gas plants, and wherever a combustible gas-air mixture may
occur.
Features
• Enclosures of rugged polyester resin
and gasketed for NEMA 4X hose down
protection

One device

Two devices

Three devices

CONTROL DEVICES
Shrouded or mushroom style

Push Button

• Factory sealed contacts rated for heavy
duty NEMA A600/Q300
explosion-protected operation

Maintained push-pull or twist-release button

Control Switch

Multiple position rotary maintained or momentary action

Pilot Light

Full voltage, resistor or transformer and multi-voltage LED types

• No external seals required for most
applications
• Comprehensive selection of control
operators including:
– Push buttons (standard or mushroom
caps) with momentary & maintained
action for multiple functions or
emergency stop

ENCLOSURES

– Rotary selector switches for maintained
or momentary operation
– Pilot lights (LED as standard) in multiple
voltages and colors
• Options for various enclosures entry
types and legend plates

Size 1

Size 2

ENTRIES AND ACCESSORIES

Hub with
Grounding locknut

Legend
Plates

Hole Plug

Lockouts

C3

D2C SERIES • CONTROLS
A S S E M B L E D C O N T R O L S TAT I O N S

D2CG2B2

D2CG2MMR3

D2CG2B7

D2CG2S3C3

D2CG8B15
The control stations on this page are the most commonly used configurations, including combinations of push buttons, pilot lights and
selector switches. See the following pages for components to configure custom stations.

F E AT U R E S - S P E C I F I C AT I O N S

ONE DEVICE, DEAD END1
Single Push Button (Momentary Contact)
Complete Units (Box & Cover)
NPT SIZE
D2CG2B1
3/4”
D2CG2B2
D2CG2B3
Push-Pull Mushroom Button (Maintained Contact)
D2CG2MMR3
3/4”
Pilot Light (120V AC Light Emitting Diode Type)
D2CG2B24CL
D2CG2B24GL
D2CG2B24RL
3/4”
D2CG2B24BL
D2CG2B24AL
D2CG2B24WL
2 Position Rotary Selector Switch (Maintained Contact)
D2CG2S2A3

3/4”

DIAGRAM

LEFT

DIAGRAM
CENTER

COLOR
GREEN
RED
BLACK

LEGEND2
START
STOP
BLANK

RED

EMERGENCY STOP

CLEAR
GREEN
RED
BLUE
AMBER
WHITE
LEGEND
RIGHT

BLANK
BLANK
BLANK
BLANK
BLANK
BLANK

3 Position Rotary Selector Switch (Maintained Contact)
D2CG2S3C3
3/4”

OFF - ON

HAND-OFF-AUTO

TWO DEVICES, DEAD END1
Two Push Buttons (Both Momentary Contact)
Complete Units (Box & Cover)
NPT SIZE
DIAGRAM
D2CG2B4
3/4”
D2CG2B7
Pilot Light (120V AC Light Emitting Diode Type) and Push Button (Momentary Contact)
D2CG2B13
3/4”

COLOR
GREEN - RED
BLACK - BLACK

LEGEND2
START - STOP
BLANK

RED LENS, BLACK BUTTON

BLANK

THREE DEVICES, DEAD END1
Pilot Light (120V AC Light Emitting Diode Type) and two push buttons (Both Momentary Contact)
Complete Units (Box & Cover)
NPT SIZE
DIAGRAM
COLOR
RED LENS, GREEN
D2CG8B15
3/4”
& RED BUTTONS
Three Push Buttons (Each Momentary Contact)
GREEN, RED
D2CG8B9
3/4”
& BLACK BUTTONS

1For 3/4” FEED-THRU, change G2 or G8 in catalog number to G5. Example D2CG2B1 becomes D2CG5B1. For other hub sizes, see page C4.
2Specify pilot light lens marking or blank button marking if required.

LEGEND2
BLANK, START, STOP

START, STOP, BLANK

C

C4

D2C SERIES • CONTROLS
E N C L O S U R E S , E N T RY F I T T I N G S , A C C E S S O R I E S , L E G E N D S

PWCG10
D2CCG12
PWBG
SIZE 1

PWCG20

D2CCG23

D2CCG24

PWBG
SIZE 2

D2CCG11

F E AT U R E S - S P E C I F I C AT I O N S

SIZE 1 BOXES

SIZE 2 BOXES

Catalog Number
PWBG0
PWBG1
PWBG2
PWBG3
PWBG4
PWBG5
PWBG6
PWBG25
PWBG26
PWBG27
PWBG37
PWBG38
PWBG39

Description
Blank - No Entries
w/1/2” NPT hub, dead end
w/3/4” NPT hub, dead end
w/1” NPT hub, dead end
w/1/2” NPT hubs, feed thru
w/3/4” NPT hubs, feed thru
w/1” NPT hubs, feed thru
w/clearance hole, 1/2” NPS
w/clearance hole, 3/4” NPS
w/clearance hole, 1” NPS
w/clearance hole, M2O
w/clearance hole, M25
w/clearance hole, M32

SIZE 1 COVERS

Catalog Number
PWBG00
PWBG7
PWBG8
PWBG9
PWBG10
PWBG11
PWBG12
PWBG31
PWBG32
PWBG33
PWBG43
PWBG44
PWBG45

Description
Blank - No Entries
w/1/2” NPT hub, dead end
w/3/4” NPT hub, dead end
w/1” NPT hub, dead end
w/1/2” NPT hubs, feed thru
w/3/4” NPT hubs, feed thru
w/1” NPT hubs, feed thru
w/clearance hole, 1/2” NPS
w/clearance hole, 3/4” NPS
w/clearance hole, 1” NPS
w/clearance hole, M20
w/clearance hole, M25
w/clearance hole, M32

SIZE 2 COVERS

PWCG10
D2CCG11
D2CCG12

Blank-no device openings
w/1 device opening 30mm
w/2 device openings 30mm

PWCG20
D2CG23
D2CG24*

Blank-no device openings
w/3 device openingS 30mm
w/4 device openings 30mm

* Space restrictions may apply for feed thru conduit entries.

ENTRY FITTINGS** & ACCESSORIES
Catalog Number
WH-1G
WH-2G
WH-3G
YOCCHP
YOCCLOAX
YOCCLOAM
YOCCLOAP
YOCCLOAFC

Description
Hub w/grounding locknut 1/2” NPT
Hub w/grounding locknut 3/4” NPT
Hub w/grounding locknut 1” NPT
Hole plug for 30mm operator
Lockout for half shroud momentary buttons
Lockout for momentary mushroom buttons
Lockout for maintained mushroom buttons
Lockout cover (clear) for buttons or switches

** For other entry openings, contact factory.

LEGEND PLATES***
Blue plate with white lettering - add to end of base catalog
number YOCCLPBE. Example YOCCLPBE02.
02 =
03 =
04 =
07 =
14 =
15 =
16 =
17 =
18 =

CLOSE
DOWN
EMERGENCY STOP
FORWARD
OPEN
POWER OFF
POWER ON
PUSH TO TEST
RESET

19 =
20 =
22 =
23 =
24 =
25 =
30 =
56 =
83 =

REVERSE
RUN
START
STOP
TEST
UP
PUSH TO RESET
OFF - ON
HAND - OFF - AUTO

Blank plates for engraving - add to end of base catalog
number YOCCLP. Example YOCCLPBE00.
WE00 = White Plate
BE00 = Blue Plate
YW00 = Yellow Plate
GN00 = Green Plate
00 = Black Plate
RD00 = Red Plate
*** contact factory for additional selections.

C5

D2C SERIES • CONTROLS
C O N T R O L O P E R AT O R S , C O N TA C T B L O C K S

Push Button - Momentary

Rotary Switch

Factory Sealed
Contact Block
1 N.O./1 N.C.

Mushroom - Maintained

Pilot Light - LED

F E AT U R E S - S P E C I F I C AT I O N S

Momentary Push Button Operators*
Catalog Number
D2CO1KX3
D2CO1GX3
D2CO1RX3
D2CO1KH3
D2CO1GH3
D2CO1RH3
D2CO1KM3
D2CO1GM3
D2CO1RM3

Description
Black Push Button Full Shroud
Green Push Button Full Shroud
Red Push Button Full Shroud
Black Push Button Half Shroud
Green Push Button Half Shroud
Red Push Button Half Shroud
Black Push Button Mushroom
Green Push Button Mushroom
Red Push Button Mushroom

Maintained Mushroom Push Button Operators*
D2COM1K3
D2COM1G3
D2COM1R3
D2COT1R3

Black Push-Pull Mushroom
Green Push-Pull Mushroom
Red Push-Pull Mushroom
Red Twist to Release Mushroom

Rotary Selector Switch Operators*
D2CO52A3
D2CO53C3
D2CO63
D2CO73
D2CO143
D2CO153

Maintained 2-Position
Maintained 3-Position
Momentary Right, 2-Position
Maintained Center 3-Position
Maintained Left & Center 3-Position
Maintained Right & Center 3-Position

* Operators supplied with one universal factory sealed 1 N.O. + 1 N.C. contact block. For
operator provided with two contact blocks, change last digit (3) of catalog number to 8.
For actuator only, change (3) to O.

LED Pilot Light Devices
Add to end
A23 =
A4
=
AMV =
B23 =
B4
=
BMV =
C23 =
C4
=
CMV =
G23 =
G4
=
GMV =
R23 =
R25R =
R25T =
R4
=
RMV =
W23 =
W4 =
WMV =

of base catalog number D2CO3. Example D2CO3A23.
Amber 120V AC/DC
Amber 24V AC/DC
Amber Multi-voltage 20V-254V AC/DC
Blue 120V AC/DC
Blue 24V AC/DC
Blue Multi-voltage 20V-254V AC/DC
Clear 120V AC/DC
Clear 24V AC/DC
Clear Multi-voltage 20V-254V AC/DC
Green 120V AC/DC
Green 24V AC/DC
Green Multi-voltage 20V-254V AC/DC
Red 120V AC/DC
Red 480VAC/DC resistor
Red 480VAC transformer
Red 24V AC/DC
Red multi-voltage 20V-254V AC/DC
White frosted 120V AC/DC
White frosted 24V AC/DC
White frosted Multi-voltage 20V-254V AC/DC

Factory Sealed Contact Block
Catalog Number
D2CU
(add suffix R for rotary
selector switches)

Description
Factory Sealed Contact Block
1 Normally Open and
1 Normally closed

Diagram

Hazardous Rating:
Class I, Division 2, Groups A,B,C,D; Class I, Zone 2, Groups IIB+H2, IIA, T6
Terminal Capacity:
22 thru 12 AWG [0.5-2.5mm2] copper, solid or standed conductors.
Tightening torque 7 in-lbs. (tolerance +3.0/0.0) [~ 0.8Nm]
Contact Electrical Ratings:
NEMA A600- 7200 VA (Make), 720 VA (Break), 10 Amps Cont. @600V AC (Thermal)
NEMA Q300- 69 VA (Make & Break),
2.5 Amps Cont. @250V DC (Thermal)

C

C6

D2C SERIES • CONTROLS
C U S T O M S TAT I O N S O R D E R I N G F O R M , E N C L O S U R E D I M E N S I O N S

Design your own DuraTech configuration from components by completing the following:
®


1

Box Size

2


1/2 3/4 1

Hub Size


1/2 3/4 1

Clearance Hole NPS


1

Cover Size

Dead End



Feed Thru



M20 M25 M32

Metric


1

2

Number of Devices

2

3

4

Select Devices From Top (Position 1) to Bottom
Device

Nameplate

Position 1_
________________________________________________________________________________________________________________________________
Position 2_
________________________________________________________________________________________________________________________________
Position 3_
________________________________________________________________________________________________________________________________
Position 4_
________________________________________________________________________________________________________________________________

Options



C7

D2C SERIES • CONTROLS
C O N T R O L S O P E R AT O R D I M E N S I O N S

Operators bought separately are provided with gaskets to accommodate panel thickness for D2C series enclosures.
Full-Shrouded Momentary Push Button Operator
(53)

(11)

Half-Shrouded Button

(63)

(53)

(53)

(63)

(21)

Mushroom Push Button

Selector Switch Device

Pilot Light Multi-Voltage 20V-240V AC/DC

Pilot Light 120V AC (Full Voltage)

C

Legend Plate

C8

CS SERIES • CONTROLS
C O N T R O L S TAT I O N S

Class I, Div. 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4x
(A)Ex de IIC T6 IP66
FRP Enclosure

Stainless Steel Enclosure

F E AT U R E S - S P E C I F I C AT I O N S
Applications
Hazardous and corrosive environments
such as refineries, chemical plants,
water treatment and bio gas plants, and
wherever a combustible gas-air mixture
or combustible dust may occur.
Features
• Enclosures of Fiberglass Reinforced
Polyester or Stainless Steel.
• Durable EPDM gasket on enclosure
is concealed to protect it from
damage or premature aging by UV
light and chemical elements
• Snap-on mounting of individual explosion-protected control components to
notched DIN-like rail
• Contact element utilizes a parallel
bridge contact with a four point
(H- contact) to ensure the utmost
reliability even with very low control
voltages and currents
• Fluorosilicate gasket in standard
pushbutton actuators is suitable for a
wide range of atmospheric conditions
(-50°C to 40°C)
• LED Pilot lights (incorporating
advanced voltage-sensing electronics)
operate on any voltage from 20V- 254V,
AC or DC
• Control switches in many configurations
• Illuminated (Push-To-Test) push buttons, ammeters, potentiometers and
other control components available
• No external seals required for most
applications

Two Types of Enclosure Materials
• Fiberglass Reinforced Polyester (FRP)
• 316L Stainless Steel
“THE” Standard in Hazardous
Location Control

Integral
Mounting Slots (holes)
Explosion Protected
LED Pilot Light

Recessed
EPDM
Gasketing

Component
Mounting Rail
Spring Washer
& Retainer Nut

Pilot Light Bezel

RUN

Station I.D. Label
(optional)
Ground Plate
With Terminals
Explosion
Protected
Contact Block

Conduit Hub
or Cable
Gland Entry

Stainless Steel Cover Screws
Actuator Gasket
Dual Push-Button Actuator

1CSA Certified for Class II, Div. 1&2, EFG. UL LIsted for Class II, Div. 2, FG.

Easy Change-out
Components Snap in Place

C9

CS SERIES • CONTROLS
C O N T R O L S TAT I O N S - S TA N D A R D C O N F I G U R AT I O N S

Start
Push Button
Station

Start/Stop
Push Button
Station

Class I, Div. 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4X
(A)Ex de IICT6 IP66

Pilot Light
Station

E-Stop
Push Button
Station

F E AT U R E S - S P E C I F I C AT I O N S
C S M O M E N TA R Y S I N G L E P U S H B U T T O N
CATALOG
NUMBER

The control stations on this page are
the most commonly used configurations, including combinations of pilot
lights and push buttons.

CONTACT ARRANGEMENT
IEC

NEMA

23

11

24

12

CSF124UO11
CSS124UO11

CONTACT
BLOCKS

BUTTON
COLOR

NAMEPLATE
MARKING

1 N.O. / 1 N.C.

Green

CONTACT
BLOCKS

BUTTON
COLOR

1 N.O. / 1 N.C.

Green

Start

1 N.O. / 1 N.C.

Red

Stop

Start

Wiring Entry Logic
Insert one of the digits below to complete the
control station catalog number.

C S M O M E N TA R Y S TA R T- S T O P P U S H B U T T O N S
CATALOG
NUMBER

CONTACT ARRANGEMENT
IEC

B O X E S W I T H I N T E R N A L G R O U N D P L AT E
(for MC/TC/TEC Cable Connectors)

23

CSF224UO11UO12

1/2" NPT Top Feed

A

1/2" NPT Bottom Feed

B

1/2" NPT Feed Through

C

3/4" NPT Top Feed

D

3/4" NPT Bottom Feed

E

3/4" NPT Feed Through

F

BOXES WITH CONDUIT HUB
1/2" NPT Top Feed

0

1/2" NPT Bottom Feed

1

1/2" NPT Feed Through

2

3/4" NPT Top Feed

3

3/4" NPT Bottom Feed

4

3/4" NPT Feed Through

5

B O X E S W I T H N O N - METALLIC CABLE GLAND
(Standard for IEC/CENELEC)

CSS224UO11UO12

NAMEPLATE
MARKING

11

24

12

23

11

24

12

START

STOP

C S M A I N TA I N E D E M E R G E N C Y S T O P P U S H B U T T O N
CATALOG
NUMBER

CSF124C150

CONTACT ARRANGEMENT
IEC

NEMA

12

I-0

11

CONTACT
BLOCKS

BUTTON
COLOR

NAMEPLATE
MARKING

2 N.C.

Red Large

VOLT

COLOR

NAMEPLATE
MARKING

Red LED

—

C

22

CSS124C150

E-Stop

21

CS SINGLE PILOT LIGHT
CATALOG
NUMBER

M25 Compression Gland Top Feed

6

M25 Compression Gland Bottom Feed

7

CSF124PLRO

M25 Compression Gland Feed Through

8

CSS124PLRO

Special

9

1CSA Certified for Class II, Div. 1&2, EFG.
UL Listed for Class II, Div. 2, FG.

NEMA

CONTACT ARRANGEMENT
IEC

X1

NEMA

X2

•

• 20V-254V AC / DC

Wiring entry: 4=3/4" NPT Bottom Feed. For other entries, see Wiring Entry Logic table at left.
Housing material: (F) FRP, (S) Stainless Steel.

C10

CS SERIES • CONTROLS
C O N T R O L S TAT I O N S - S TA N D A R D C O N F I G U R AT I O N S

Pilot Light &
2 Push Button
Station

Pilot Light &
Start/Stop Push
Button Station

Selector Switch
Station

Class I, Div. 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4X
(A)Ex de IICT6 IP66

Pilot Light and
Selector Switch
Station

F E AT U R E S - S P E C I F I C AT I O N S
C S P I L O T L I G H T ( R E D L E D ) / M O M E N TA R Y D O U B L E P U S H B U T T O N S
CATALOG
NUMBER

CONTACT ARRANGEMENT
IEC

CONTACT
BLOCKS

VOLT

NEMA

The control stations on this page are
the most commonly used configurations, including combinations of pilot
lights, push buttons and selector
switches.

CSF224PLROU231

23

CSS224PLROU231

24
11

Wiring Entry Logic

C S P I L O T L I G H T ( R E D L E D ) / M O M E N TA R Y S TA R T- S T O P P U S H B U T T O N S

Insert one of the digits below to complete the
control station catalog number.

B O X E S W I T H I N T E R N A L G R O U N D P L AT E
(for MC/TC/TEC Cable Connectors)
1/2" NPT Top Feed

START

STOP

20V-254V, AC/DC

B

1/2" NPT Feed Through

C

3/4" NPT Top Feed

D

3/4" NPT Bottom Feed

E

3/4" NPT Feed Through

F

BOXES WITH CONDUIT HUB

CATALOG
NUMBER

CONTACT ARRANGEMENT
IEC

0

1/2" NPT Bottom Feed

1

1/2" NPT Feed Through

2

3/4" NPT Top Feed

3

3/4" NPT Bottom Feed

4

3/4" NPT Feed Through

5

X1

X2

23

11

CSS334PLROU011U012

24
23

12

24

12

CATALOG
NUMBER

6

M25 Compression Gland Bottom Feed

7

M25 Compression Gland Feed Through

8

Special

9

Stop

11

START

STOP

CONTACT
BLOCKS

BUTTON NAMEPLATE
COLOR MARKING

1 N.O. / 1 N.C.

Green

Start

1 N.O. / 1 N.C.

Red

Stop

20V-254V, AC/DC

CONTACT ARRANGEMENT
IEC
45°
13
23

CONTACT
BLOCKS

BUTTON
COLOR

2-Pos./2-Pole

—

NEMA
135°
14
24

OFF

NAMEPLATE
MARKING

ON

13 23
° °

CSS124NO21

Off-On

° °
14 24

C S M A I N TA I N E D 3 - P O S I T I O N S E L E C T O R S W I T C H
CATALOG
NUMBER

CSF124N273

M25 Compression Gland Top Feed

Red

C S M A I N TA I N E D 2 - P O S I T I O N S E L E C T O R S W I T C H

B O X E S W I T H N O N - M E TA L L I C CABLE GLAND
(Standard for IEC/CENELEC)

Start

1 N.O./1 N.C.

VOLT

NEMA

CSF334PLROU011U012

CSF124NO21

1/2" NPT Top Feed

Green

12

A

1/2" NPT Bottom Feed

1CSA Certified for Class II, Div. 1&2, EFG.
UL LIsted for Class II, Div. 2, FG.

X2

X1

BUTTON NAMEPLATE
COLOR MARKING

CSS124N273

CONTACT ARRANGEMENT
IEC

CONTACT
BLOCKS

BUTTON
COLOR

3-Pos./2-Pole

—

NEMA

45°
135°
12
11 4
23
24
90°
11 23
°
°

HAND OFF

NAMEPLATE
MARKING

AUTO

H-O-A

° °
12 24

C S P I L O T L I G H T / M A I N TA I N E D 2 - P O S I T I O N S E L E C T O R S W I T C H
CATALOG
NUMBER

CSF224PLRON021
CSS224PLRON021

CONTACT ARRANGEMENT
IEC
45°
13
23

•

VOLT

NEMA
135°
14
24

13 23
° °

OFF

•

ON

CONTACT
BLOCKS

20V-254V, AC/DC 2-Pos./2-Pole

COLOR

Red LED

NAMEPLATE
MARKING

Off-On

° °
14 24

Wiring entry: 4=3/4" NPT Bottom Feed. For other entries, see Wiring Entry Logic table at left.
Housing material: (F) FRP, (S) Stainless Steel.

C11

CS SERIES • CONTROLS
C O N T R O L S TAT I O N S D I M E N S I O N A L D ATA

FRP Enclosure

Stainless Steel Enclosure

F E AT U R E S - S P E C I F I C AT I O N S
FRP Dimensions

3.1"
(80)
2.8"
(70)

3.78
(97)
.43"
(11)

0.2"
(5.5)

0.3"
(7)

3.1"
(80)
2.8"
(70)
0.2"
(5.5)

0.3"
(7)

3.1"
(80)
2.8"
(70)

B

0.3"
(7)

3.7"
(94)
5.5"
(139)

B

ø 0.2"
ø (5.5)

ø 0.2"
ø (5.5)

A

ø 0.2"
(ø 5.5)
1.9"
(48)
3.7"
(93)

B

7.3"
(185)

A
A

5.5"
(140)

0.2"
(5.5)

0.2"
(5.5)

0.2"
(5.5)

0.2"
(5.5)

CSF 33

CSF12/CSF 22

CSF 11 Compact

CSF Deep
for 4 Pole Switches

C

CSS 12
CSS 22

8.9” (226)

8.2” (207)

Steel Dimensions

CSS 33

C12

FXCS SERIES • CONTROLS
FA C T O RY S E A L E D C O N T R O L S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)

Listed - File E53360
Certified - File LR11714
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
SEAL-X®
Applications
SEAL-X® Series Factory Sealed push
button stations, selector switches, pilot
lights and tumbler switches are used to
prevent the igniting of external hazardous atmospheres by the enclosed
arcing devices in such areas as:
• Hazardous locations due to the presence of flammable gases or vapors,
combustible dusts or easily ignitable
fibers or flyings
• Installations at petroleum refineries,
chemical and petrochemical plants
and other processing or storage facilities where similar hazards exist
• Use in conjunction with magnetic
starters or contactors for remote control of motors
Features
• Elimination of external sealing
requirements
• Lower installation cost
• NEMA 3 weatherproof
• Color coded wiring-more wiring
space-easier field installation
• Stainless steel captive screws for
cover assembly
• Ground boss for grounding in the
splice box
• Device bodies and covers are cast
copper-free aluminum alloy

• Cast conduit hubs 1/2", 3/4" and 1"
either dead end or feed through
standard in both single and two
gang assemblies
• Push button, selector switches and
pilot light bodies are copper-free
aluminum
• Operating shaft in both push buttons
and selector switches are stainless
steel
• Miniature and standard size push
buttons. (Miniature 3/4" overall diameter, standard 1 3/8" overall diameter)
Factory Sealed devices eliminate the
need for external sealing. The difference is the use of a sealing plate
between the arcing device and the
junction box. The sealing plate confines ignited gases, vapors, flames,
or dust to the arcing device chamber,
preventing them from traveling through
the conduit system. Accurately ground
flanges on both sides of the sealing
plate provide flame-tight joints. Factory
poured seals around the wiring pigtails
insure safe sealing. (FXCS Series)

Electrical Rating
Push button stations, selector switches
600 VAC max. heavy duty.

C O N TA C T B L O C K R AT I N G S
CURRENT 120 VAC 240 VAC 480 VAC 600 VAC
INRUSH

60

30

BREAKING

6

3

CARRYING

10

10

15

12

1.5

1.2

10

10

D C R AT I N G S ( M A X . A M P S )
CURRENT

125 VDC

INRUSH

.55

BREAKING

.55

CARRYING

2.50

250 VDC
.275
.275
2.50

M O D I F I C AT I O N S
SUFFIX
NUMBER

DESCRIPTION

AL

Pilot light lens-amber

CL

Pilot light lens-clear

GL

Pilot light lens-green

RL

Pilot light lens-red

MR

Mushroom headPush button (red)

LO

Push button LOCKOUT 1

LOP

Selector switch-padlock
LOCKOUT

1 LOCKOUT must be installed at the factory.

LED lamps available. See page C39.

C13

FXB SERIES • CONTROLS
FA C T O RY S E A L E D S P L I C E B O X E S / S E A L I N G M E T H O D S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. I & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)

Listed - File E53360

FXB-2
Dead End

FXB-5
Feed Thru

FXB-8
Double Gang Dead End

Certified- File LR11714

FXB-11
Double Gang Feed Thru

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Splice Boxes
The FXB Series of splice boxes are
designed for use with the FXCS and
FXS Series of cover sub-assemblies.
FXB BACK BOX SELECTION AND DIMENSIONS
CATALOG NUMBER

DESCRIPTION

EXTERNAL

HUB
SIZE

LENGTH

WIDTH

MOUNTING
DEPTH

VERTICAL

HORIZONTAL

FXB-1

Single gang/Dead-end

1/2"

6-13/16"

3-11/16"

1-3/4"

6-3/16"

2-1/4"

FXB-2

Single gang/Dead-end

3/4"

6-13/16"

3-11/16"

1-3/4"

6-3/16"

2-1/4"

FXB-3

Single gang/Dead-end

1"

6-13/16"

3-11/16"

1-3/4"

6-3/16"

2-1/4"

FXB-4

Single gang/Feed-thru

1/2"

6-13/16"

3-11/16"

1-3/4"

6-3/16"

2-1/4"

FXB-5

Single gang/Feed-thru

3/4"

6-13/16"

3-11/16"

1-3/4"

6-3/16"

2-1/4"

FXB-6

Single gang/Feed-thru

1"

6-13/16"

3-11/16"

1-3/4"

6-3/16"

2-1/4"

FXB-7

Double gang/Dead-end

1/2"

6-13/16"

7-17/32"

2

6-3/16"

2-1/4"

FXB-8

Double gang/Dead-end

3/4"

6-13/16"

7-17/32"

2

6-3/16"

2-1/4"

FXB-9

Double gang/Dead-end

1"

7

7-17/32"

2

6-3/16"

2-1/4"

FXB-10

Double gang/Feed-thru

1/2"

6-13/16"

7-17/32"

2

6-3/16"

2-1/4"

FXB-11

Double gang/Feed-thru

3/4"

6-13/16"

7-17/32"

2

6-3/16"

2-1/4"

FXB-12

Double gang/Feed-thru

1"

7

7-17/32"

2

6-3/16"

2-1/4"

C

C14

FXCS SERIES • CONTROLS
FA C T O RY S E A L E D C O V E R A S S E M B L I E S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. I & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)

Listed - File E53360 and/or E12379
Certified - File LR11714

Single Push Button

Pilot Light

Double Push Button

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S

F X C S M O M E N TA R Y C O N TA C T S I N G L E P U S H B U T T O N

COVER WITH DEVICE
FXCS-0B1
FXCS-0B2
FXCS-0B3

CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

HUB
SIZE

FXCS-1B1

FXCS-4B1

1/2"

FXCS-2B1

FXCS-5B1

3/4"

FXCS-1B2

FXCS-4B2

1/2"

FXCS-2B2

FXCS-5B2

3/4"

FXCS-1B3

FXCS-4B3

1/2"

FXCS-2B3

FXCS-5B3

3/4"

BUTTON
COLOR

DIAGRAM

NAMEPLATE
MARKING 1

••

Green

Start

••

Red

Stop

••
••

Black

Specify

F X C S M O M E N TA R Y C O N TA C T D O U B L E P U S H B U T T O N
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU
FXCS-0B4
FXCS-0B4-U
FXCS-0B5
FXCS-0B7

HUB
SIZE

FXCS-1B4

FXCS-4B4

1/2"

FXCS-2B4

FXCS-5B4

3/4"

FXCS-1B4U

FXCS-4B4-U

1/2"

FXCS-2B4U

FXCS-5B4-U

3/4"

BUTTON
COLOR

DIAGRAM

NAMEPLATE
MARKING 1

••

••

Green/Red

Start/Stop

••
••

••
••

Green/Red

Start/Stop

FXCS-1B5

FXCS-4B5

1/2"

FXCS-2B5

FXCS-5B5

3/4"

••

••

Green/Green

Start/Stop

••
••

••
••

Black/Black

Specify

FXCS-1B7

FXCS-4B7

1/2"

FXCS-2B7

FXCS-5B7

3/4"

FXCS PILOT LIGHT

COVER WITH DEVICE
FXCS-0B24CL
FXCS-0B24GL
FXCS-0B24RL

CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

HUB
SIZE

FXCS-1B24CL

FXCS-4B24CL

1/2"

FXCS-2B24CL

FXCS-5B24CL

3/4"

FXCS-1B24GL

FXCS-4B24GL

1/2"

FXCS-2B24GL

FXCS-5B24GL

3/4"

FXCS-1B24RL

FXCS-4B24RL

1/2"

FXCS-2B24RL

FXCS-5B24RL

3/4"

DIAGRAM

VOLT

LENS
COLOR 2

NAMEPLATE
MARKING 1

120V

Clear

Specify

120V

Green

Specify

120V

Red

Specify

1 For other than standard marking, refer to the special feature section of price list.

2 Lens colors other than listed may be specified by changing lens color suffix. See modifications page C12.

NOTE: Boxes and covers shipped separately.
*For control stations with 1" conduit openings or for double gang assemblies, order cover with device and box as separate components.

C15

FXCS SERIES • CONTROLS
FA C T O RY S E A L E D C O N T R O L S TAT I O N C O V E R A S S E M B L I E S

Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, IlA
Class II, Div. I & 2, Groups E,F,G Class Ill
NEMA 3, 7(C,D) 9(E,F,G)

Double Pilot Lights

Pilot Light
Two Mini Push Buttons
Pilot Light
Push Button

Listed - File E53360 and /or E12379

Maintained
Push Button

Certified - File LR11714
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S

FXCS DOUBLE PILOT LIGHTS
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU

HUB
SIZE

FXCS-1B30CL

FXCS-4B30CL

1/2"

FXCS-2B30CL

FXCS-5B30CL

3/4"

FXCS-1B30GL

FXCS-4B30GL

1/2"

FXCS-2B30GL

FXCS-5B30GL

3/4"

FXCS-0B30CL
FXCS-0B30GL
FXCS-0B30RL
FXCS-0B30RL-GL

FXCS-1B30RL

FXCS-4B30RL

1/2"

FXCS-2B30RL

FXCS-5B30RL

3/4"

FXCS-1B30RL-GL

FXCS-4B30RL-GL

1/2"

FXCS-2B30RL-GL

FXCS-5B30RL-GL

3/4"

LAMP
VOLTS

DIAGRAM

LENS
COLOR 2

NAMEPLATE
MARKING1

120V

Clear

Specify

120V

Green

Specify

120V

Red

Specify

120V

Red/Green

Specify

F X C S M O M E N TA R Y C O N TA C T P U S H B U T T O N A N D P I L O T L I G H T
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU
FXCS-0B13-C
FXCS-0B13-O
FXCS-0B13-U

HUB
SIZE

FXCS-1B13-C

FXCS-4B13-C

1/2"

FXCS-2B13-C

FXCS-5B13-C

3/4"

FXCS-1B13-O

FXCS-4B13-O

1/2"

FXCS-2B13-O

FXCS-5B13-O

3/4"

FXCS-1B13-U

FXCS-4B13-U

1/2"

FXCS-2B13-U

FXCS-5B13-U

3/4"

DIAGRAM

••
••
••
••

NAMEPLATE
MARKING 1

LAMP
VOLTS

BUTTON
COLOR

120V

Red

Clear

Stop

Specify

120V

Green

Green

Start

Specify

120V

Black

Red

Specify

Specify

LENS
COLOR 2

BUTTON

LENS

F X C S M O M E N TA R Y C O N TA C T 2 M I N I P U S H B U T T O N A N D 1 P I L O T L I G H T
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU
FXCS-0A15

HUB
SIZE

FXCS-1A15

FXCS-4A15

1/2"

FXCS-2A15

FXCS-5A15

3/4"

DIAGRAM

• •• •

BUTTON
COLOR

Red/Green

LENS
COLOR2

Red

120 VAC

NAMEPLATE
MARKING1
BUTTON

LENS

Stop
Start

Specify

F X C S M A I N TA I N E D C O N TA C T - P U S H / P U L L M U S H R O O M 4
BUTTON COLOR

C O N TA C T T Y P E

C O V E R A S S E M B LY C AT. #

GREEN

1NO/1NC

FXCS-OMMG3

RED

1NO/1NC

FXCS-OMMR3

BLACK

1NO/1NC

FXCS-OMMK3

C ATA L O G # W I T H L O C K O U T #

N A M E P L AT E M A R K I N G

FXCS-OMMR3-LOM

3

1 For other than standard marking, refer to the special feature section of price list.

2 Lens colors other than listed may be specified by changing lens color suffix. See modifications page C12.
3 Three nameplates supplied (Start/Stop, Blank, Emergency Stop) with FXCS maintained push button.

4 Operation-when push button is depressed and contacts activated, operator will remain in depressed position until pulled out to

normal position.
NOTE: Boxes and covers shipped separately.
*For control stations with 1" conduit opening or for double gang assemblies, order cover with device and box as separate components.

C

C16

FXCS SERIES • CONTROLS
FA C T O RY S E A L E D C O V E R A S S E M B L I E S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, lIA
Class II, Div. 1 & 2, Groups E,F,G Class Ill
NEMA 3, 7(C,D) 9(E,F,G)

Listed - File E53360 and/or E12379
Certified - File LR11714

Key Selector Switch

Selector Switch

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
F X C S T W O P O S I T I O N S E L E C T O R S W I T C H – M A I N TA I N E D C O N TA C T 1
CATALOG NUMBER
HUB
SIZE

FXCS-0S2A1

1/2"

STANDARD
COMPLETE UNITS
(BOX & COVER)
DEAD-END FEED-THRU
FXCS-1S2A1 FXCS-4S2A1

FXCS-0S2A1

3/4"

FXCS-2S2A1 FXCS-5S2A1

FXCS-0S2A5

1/2"

FXCS-1S2A5 FXCS-4S2A5

FXCS-0S2A5

3/4"

FXCS-2S2A5 FXCS-5S2A5

KEYED
COVER
WITH
DEVICE
FXCS-0K2A1
FXCS-0K2A5

LEFT POSITION

KEYED
COMPLETE UNITS 2
(BOX & COVER)
DEAD-END FEED-THRU
FXCS-1K2A1 FXCS-4K2A1

LEFT
CONTACT

FXCS-2K2A1 FXCS-5K2A1

••
••
••

FXCS-1K2A5 FXCS-4K2A5
FXCS-2K2A5 FXCS-5K2A5

RIGHT POSITION
LEFT
CONTACT

RIGHT
CONTACT

••

••

STANDARD
COVER
WITH
DEVICE

RIGHT
CONTACT

••

••
••

••
••

••
••

F X C S T H R E E P O S I T I O N S E L E C T O R S W I T C H – M A I N TA I N E D C O N TA C T 1

FXCS-0S3C4

1/2"

FXCS-0S3C4

3/4"

FXCS-2S3C4

FXCS-5S3C4

FXCS-0S3C5

1/2"

FXCS-1S3C5

FXCS-4S3C5

FXCS-0S3C5

3/4"

FXCS-2S3C5

FXCS-5S3C5

KEYED
COVER
WITH
DEVICE
FXCS-0K3C4
FXCS-0K3C5

LEFT POSITION
CENTER POSITION
RIGHT POSITION
KEYED
COMPLETE UNITS 2
LEFT
RIGHT
LEFT
RIGHT
LEFT
RIGHT
(BOX & COVER)
CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT
DEAD-END FEED-THRU
FXCS-1K3C4 FXCS-4K3C4
FXCS-2K3C4

FXCS-5K3C4

FXCS-1K3C5

FXCS-4K3C5

FXCS-2K3C5

FXCS-5K3C5

••

••

• •
• •

• •
• •

••
• •
• •

••

••

••

• •
• •

• •
• •

HUB
SIZE

STANDARD
COMPLETE UNITS
(BOX & COVER)
DEAD-END FEED-THRU
FXCS-1S3C4 FXCS-4S3C4

• •
• •

CATALOG NUMBER
STANDARD
COVER
WITH
DEVICE

FXCS TWO POSITION SELECTOR SWITCH – SPRING RETURNED1

3/4"

FXCS-2S2L3F FXCS-5S2L3F

FXCS-OK2L3F22D

KEYED
COMPLETE UNITS 2
(BOX & COVER)
DEAD-END
FEED-THRU
FXCS-1K2L3F22D FXCS-4K2L3F22D
FXCS-2K2L3F22D FXCS-5K2L3F22D

LEFT POSITION
LEFT
CONTACT

RIGHT POSITION

RIGHT
CONTACT

••

••

LEFT
CONTACT

RIGHT
CONTACT

••

1/2"

FXCS-0S2L3F

HUB
SIZE

••

FXCS-0S2L3F

CATALOG NUMBER
STANDARD
KEYED
COMPLETE UNITS
COVER
(BOX & COVER)
WITH
DEVICE
DEAD-END FEED-THRU
FXCS-1S2L3F FXCS-4S2L3F

STANDARD
COVER
WITH
DEVICE

TYPE OPERATION — Spring return to left from right — Maintained in left — 1 N.O. Contact — 1 N.C. Contact

FXCS THREE POSITION SELECTOR SWITCH – SPRING RETURNED1

FXCS-5S3M6G

FXCS-0S3L6G

1/2”

FXCS-1S3L6G

FXCS-4S3L6G

FXCS-0S3L6G

3/4”

FXCS -2S3L6G

FXCS-5S3L6G

FXCS-0S3R6G

1/2”

FXCS-1S3R6G

FXCS-4S3R6G

FXCS-0S3R6G

3/4”

FXCS-2S3R6G

FXCS-5S3R6G

FXCS-0K3M6G32D FXCS-1K3M6G32D FXCS-4K3M6G32D
FXCS-2K3M6G32D FXCS-5K3M6G32D
FXCS-0K3L6G32D
FXCS-0K3R6G32D

1Nameplates are double sided.

FXCS-1K3L6G32D FXCS-4K3L6G32D
FXCS-2K3L6G32D FXCS-5K3L6G32D
FXCS-1K3R6G32D FXCS-4K3R6G32D
FXCS-2K3R6G32D FXCS-5K3R6G32D

••

LEFT
CONTACT

••

RIGHT POSITION

RIGHT
CONTACT

LEFT
CONTACT

RIGHT
CONTACT

••

••

TYPE OPERATION — Spring return to center from left or right — Maintained in center — 2 N.O. Contacts

••

••

••

••

TYPE OPERATION — Spring return to center from right — Maintained center and left 2 N.O. Contacts

••

FXCS-4S3M6G

FXCS-2S3M6G

RIGHT
CONTACT

CENTER POSITION

••

••

••

••

••

FXCS-1S3M6G

3/4”

LEFT
CONTACT

••

1/2”

FXCS-0S3M6G

LEFT POSITION

••

FXCS-0S3M6G

KEYED
COMPLETE UNITS 2
(BOX & COVER)
DEAD-END
FEED-THRU

••

HUB
SIZE

••

CATALOG NUMBER
STANDARD
KEYED
COMPLETE UNITS
COVER WITH
(BOX & COVER)
DEVICE
DEAD-END
FEED-THRU

STANDARD
COVER WITH
DEVICE

TYPE OPERATION — Spring return to center from left — Maintained center and right 2 N.O. Contacts

For other than standard marking, refer to the special feature section of the price list.
STANDARD NAMEPLATE MARKINGS — 2 POSITION — Blank or Off-On — 3 POSITION — Blank or Hand-Off-Auto.
2Key operated selector switches are randomly keyed with keys removable in all positions.
For keyed alike or key removable in other than all positions contact factory.
For control stations with 1" conduit opening or for double gang assemblies, order cover with device and box as separate components.

C17

FXS SERIES • CONTROLS
FA C T O RY S E A L E D T U M B L E R S W I T C H E S A N D
G R O U N D FA U LT I N T E R R U P T E R

For GFI Protection with
receptacle, See page PR26

Class I, Div. I & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)

Ground Fault Interrupter

Tumbler Switches

F E AT U R E S - S P E C I F I C AT I O N S
Applications
FXS Tumbler Switches are suitable for
applications where making, breaking or
changing connections in an electrical
circuit is required and where conditions
of load do not exceed the switch ratings.
Listed - File E53360 and/or Ffile E10501
Certified - File LR11714

FXS TUMBLER SWITCHES
CATALOG NUMBER
COMPLETE UNIT
COVER
(BOX, COVER AND SWITCH)
WITH SWITCH DEAD-END
FEED-THRU
FXS-1C
FXS-2C

See files for details or call Killark.

Applications
FXS Ground Fault Interrupters are
designed to interrupt a circuit when a
ground fault is detected on equipment
which may be handled by personnel in
hazardous locations.

FXS-8C

Features
• Test and Reset push buttons are
provided on cover assembly. Unit
should be tested monthly
• Includes new GFI to meet latest
UL943 GFCI standards revisions
• Exterior gasket provides NEMA 3
weatherproof protection
• Ground boss for grounding in the
splice box
• Color coded wiring
• Captive cover bolts are made from
stainless steel

FXS-6C

Electrical Rating
GFI units are rated at 20A, 120 VAC,
60HZ. Class A.
4-6 miliamp trip setting
Trip Time-UL Curve
Listed - File E80595

FXS-3C
FXS-5C

FXS-1D
FXS-2D
FXS-4C

SWITCH
STYLE

HUB
SIZE

FXS-11C

FXS-41C

1/2"

FXS-21C

FXS-51C

3/4"

FXS-12C

FXS-42C

1/2"

FXS-22C

FXS-52C

3/4"

FXS-18C

FXS-48C

1/2"

FXS-28C

FXS-58C

3/4"

FXS-13C

FXS-43C

1/2"

FXS-23C

FXS-53C

3/4"

FXS-15C

FXS-45C

1/2"

FXS-25C

FXS-55C

3/4"

FXS-16C

FXS-46C

1/2"

FXS-26C

FXS-56C

3/4"

FXS-11D

FXS-41D

1/2"

FXS-21D

FXS-51D

3/4"

FXS-12D

FXS-42D

1/2"

FXS-22D

FXS-52D

3/4"

—

—

—

SWITCH RATING
120/277 VAC, 1Ø

1-POLE

20 A 2

2-POLE

20 A 2

3-POLE

1

3-WAY/
SPDT (No off)

20 A 2

SPDT (Center off)

20 A 2

DPDT (No off)

20 A 2

1-POLE

30 A 2

2-POLE

30 A 2

4-WAY

20 A 2

1 Rated 15 amperes, 240/480 VAC., 3Ø; 3HP-240 VAC., 5 HP-480 VAC.
2 Horsepower rated 1 HP at 120 VAC, 2 HP at 240 VAC.

F X S G R O U N D F A U LT I N T E R R U P T E R †
CATALOG NUMBER
COMPLETE UNIT

COVER ASSEMBLY

FXS-GFI-1020

FXS-GFIO3

FXB-1

FXS-GFI-2020

FXS-GFIO3

FXB-2

FXS-GFI-3020

FXS-GFIO3

FXB-3

FXS-GFI-1120

FXS-GFIO3

FXB-4

FXS-GFI-2120

FXS-GFIO3

FXB-5

FXS-GFI-3120

FXS-GFIO3

FXB-6

HUB
SIZE

BACK BOX*

1/2"
DEAD
END
FEED
THRU

3/4"
1"
1/2"
3/4"
1"

For control stations with 1" conduit opening or for double gang assemblies, order cover with device
and box as separate components.
*Boxes and covers shipped separately.

Certified - File LR61895

C

†See page DE25 for additional ground fault control stations.

See files for details or call Killark.
F X S G R O U N D F A U LT I N T E R R U P T E R W I T H L E D L A M P
CATALOG NUMBER FOR COVER ASSEMBLY
* Order FXB back box as seperate item.

FXS-GFIO3PL

C18

XCS/XS/SWB SERIES • CONTROLS
C O N T R O L S TAT I O N S E X T E R N A L S E A L I N G R E Q U I R E D

Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Listed - File E53360
Certified - File LR11714, LR11712
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Applications
• Hazardous locations due to the presence of flammable gases or vapors,
combustible dusts or easily ignitable
fiber or flyings
• Installations at petroleum refineries,
chemical and petrochemical plants
and other processing or storage facilities where similar hazards exist
• Use in conjunction with magnetic
starters or contactors for remote control
of motors
Features
• Device bodies and covers are cast copperfree Aluminum alloy and provide a
wide assortment for custom assemblies
• Cast conduit hubs 1/2", 3/4" and 1"
either dead end or feed thru standard
in both single and two gang, SWB-1
thru SWB-12 device bodies
• SWB-13 thru SWB-38 are designed for
custom drilled and tapped conduit
openings on all four sides and the back
• Ground flange joint between bolted
cover and box provide required flame
path
• Push button, selector switches and pilot
light operator bodies are copper-free
aluminum
• Operating shaft in both push buttons
and selector switches are stainless
steel
• Open space between gangs for easy
wiring from one cover to another

• Miniature and standard size push buttons. (Miniature 3/4" overall diameter,
standard 1-3/8" overall diameter.)
• Contact blocks are rated heavy duty,
600 VAC max
• Internal ground screw
Electrical Rating
Push button stations, selector switches
heavy duty 600 VAC max.
Pilot lights 120 VAC.
XCS Special Assemblies
To order XCS cover assemblies for use
with multi-gang or 1" hub type SWB Series
splice boxes, simply order as follows:
Example: XCS-0B1 — Cover Assembly
SWB-6
— Splice box with
1" feed thru hubs
Example: XCS-0B1 — Cover Assembly
XCS-0B24RL— Cover Assembly
SWB-12 — Double gang
splice box
NOTE: Splice boxes and cover assemblies are
packaged in separate cartons.

C O N TA C T B L O C K R AT I N G S
CURRENT 120 VAC 240 VAC 480 VAC 600 VAC
INRUSH

60

30

BREAKING

6

3

CARRYING

10

10

15

12

1.5

1.2

10

10

D C R AT I N G S ( M A X . A M P S )
CURRENT

125 VAC

250 VAC

INRUSH

.55

.275

BREAKING

.55

CARRYING

2.50

.275
2.50

M O D I F I C AT I O N S
CATALOG
SUFFIX

DESCRIPTION

AL

Pilot light lens-amber

CL

Pilot light lens-clear

GL

Pilot light lens-green

RL

Pilot light lens-red

T2

1Pilot light transformer —
220/110VAC

T4

1Pilot light transformer —
440/110VAC

MR

Mushroom head push button
(red)

LO

Push button lockout2

LOP

Selector switch
padlock-lockout

SU1

Stainless steel cover screws

1 One transformer required for each pilot light.
Deep device bodies required for all
except single pilot light units when
transformers are used.

2 Push button lockout must be factory installed.
LED lamps available. See page C39.

SWB SERIES • CONTROLS
DEVICE FODIES FOR USE WITH XCS/XS/XT COVER ASSEMBLIES

Dead End
SWB-1-2-3 3

Feed Thru
SWB-4-5-6 3

Dead End
SWB-7-8-9 3

Feed Thru
SWB-10-11-12 3

C19

Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Listed - File E53360
Certified - LR11712

SWB-13-14

SWB-17

SWB-18

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
SWB DEVICE BODIES AND DIMENSIONS

SWB-19

SWB-20

SWB-21

CATALOG
NUMBER
SWB-1
SWB-2
SWB-3
SWB-4
SWB-5
SWB-6
SWB-7
SWB-8
SWB-9
SWB-10
SWB-11
SWB-12
SWB-13
SWB-14
SWB-17
SWB-18
SWB-19
SWB-20
SWB-21
SWB-32
SWB-33
SWB-34
SWB-38
SWB-42
SWB-45
SWB-49

SWB-32

HUB
SIZE
1/2"
3/4"
1"
1/2"
3/4"
1"
1/2"
3/4"
1"
1/2"
3/4"
1"
1
2
1
2
2
2
2
2
2
2
2

3/4"
3/4"
3/4"

LENGTH
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8”(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-1/4"(133)
5-1/4"(133)
10-3/8"(264)
5-1/4"(133)
5-1/4"(133)
5-1/4"(133)
5-1/4"(133)
12"(305)
10-3/8”(264)
12"(305)
17-1/8"(435)
5-1/4"(133)
5-1/4"(133)
5-1/4"(133)

EXTERNAL
WIDTH
3"(76)
3"(76)
3"(76)
3"(76)
3"(76)
3"(76)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
7-1/8"(181)
10-5/8"(270)
14-1/8"(359)
17-5/8"(448)
10-5/8"(270)
14-1/8"(359)
17-3/4"(451)
17-3/4"(451)
3-5/8" (92)
3-5/8"(92)
3-5/8"(92)

DEPTH
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/2"(64)
3-5/16"(84)
2-1/2"(64)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)

MOUNTING
VERTICAL
HORIZONTAL
5-3/8"(137)
2-3/8"(60)
5-3/8"(137)
2-3/8"(60)
5-3/8"(137)
2-3/8"(60)
5-3/8"(137)
2-3/8"(60)
5-3/8"(137)
2-3/8"(60)
5-3/8"(137)
2-3/8"(60)
5-3/8"(137)
2-1/2"(64)
5-3/8"(137)
2-1/2"(64)
5-3/8"(137)
2-1/2"(64)
5-3/8"(137)
2-1/2"(64)
5-3/8"(137)
2-1/2"(64)
5-3/8"(137)
2-1/2"(64)
6-1/8"(156)
2-3/8"(60)
6-1/8"(156)
2-3/8"(60)
11-3/8"(289)
2-1/8"(54)
6"(152)
5-3/4"(146)
6"(152)
9-3/16"(233)
6"(152)
12-11/16"(322)
6"(152)
16-3/16"(411)
11-1/8"(283)
9-3/16"(233)
11-3/16"(284)
12-3/4"(324)
11-5/16"(287)
16-1/4"(413)
11-5/16"(287)
16-1/4"(413)
6-1/8"(156)
2-3/8"(60)
6-1/8"(156)
2-3/8"(60)
6-1/8"(156)
2-3/8"(60)

C

1 Maximum size drilled and tapped opening 1" — Shallow device bodies.
2 Maximum size drilled and tapped opening 1-1/2" — Deep device bodies.
3SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included.

Use SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information.
SWB-13 through SWB-38 boxes are blank
without conduit openings and can be
factory or field installed. See following
page for custom conduit information.

SWB-33

SWB-34

SWB-38

SWB-42
(3/4" Dead End)
SWB-45
(3/4" Feed Thru)
SWB-48
(Two 1/2"on Bottom)
SWB-49
(Two 3/4"on Bottom)

C20

SWB SERIES • CONTROLS
C O N D U I T O P E N I N G D ATA

Conduit Opening Location Charts
C

C

1

V

1
2

X
T

J

V

G
L

P
SWB-17
A C E

A B C D E
V

1 2 3 4 5

J

X
T

1 2 3
4 5 6

X
T

G
L

R Q P O N

1 2

J

1 2 3

V

SWB-19

A B D E

A B C D E
G
L

X
T

SWB-20
A B C D E

1 2 3 4 5 G
6 7 8 9 10 L

X
V
T

R Q P O N

SWB-33

J

R QPO N

SWB-18

1 2 3 4
5 6 7 8

1 2 3 4

V

J

R P N

R Q O N

R P N
SWB-32

SWB-21

A C E

RPN

P
SWB-13-14

A BCD E

AC E

1 2 3 4 5
6 7 8 9 10
11 12 13 14 15

G
J
L

N O P Q R
SWB-38

SWB-34

F E AT U R E S - S P E C I F I C AT I O N S
To specify conduit openings select the
letter on these sketches which indicates
the position desired. All conduit openings will be evenly spaced and located
in the area indicated on the location
chart. When they are to be more accurately located, submit a sketch with
spacing dimensions. Specific conduit
openings must be located dimensionally from box centerlines to conduit centerlines and from outside back surface
of box to conduit centerline.
Ordering Instructions:
(1) Select the letter on location chart
which indicates conduit opening
position desired.
(2) Select symbol number from chart
which indicates conduit opening
type and size.
(3) Combine the conduit location letter,
size and type number, and add as a
suffix to SWB box catalog number.
Example: SWB-18-C1-J1-P1-V1

M I N I M U M H U B C E N T E R S F O R D R I L L E D A N D TA P P E D A N D U N I O N H U B S
SIZE
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"

FORM
1 MIN
2 PRE
3 GU

1 MIN
2 PRE
3 GU

1 MIN
2 PRE
3 GU

1 MIN
2 PRE
3 GU

1 MIN
2 PRE
3 GU

1/2"

3/4"

1"

1-1/4"

1-1/2"

1-3/16"(46)

—

—

—

—

1-3/8"(35)

—

—

—

—

1-5/8"(41)

—

—

—

—

1-3/8"(35)

1-1/2"(38)

—

—

—

1-1/2"(38)

1-5/8"(41)

—

—

—

1-3/4"(44)

1-13/16"(46)

—

—

—

1-1/2"(38)

1-3/4"(44)

1-13/16"(46)

—

—

1-3/4"(44)

1-7/8"(48)

2"(51)

—

—

1-7/8"(48)

2"(51)

2-1/8"(54)

—

—

1-11/16"(43)

1-15/16"(49)

2-1/16"(52)

2-5/16"(59)

—

1-15/16"(49)

2-1/16"(52)

2-1/4"(57)

2-1/2"(64)

—

2-1/16"(52)

2-1/4"(57)

2-5/16"(59)

2-1/2"(64)

—

1-15/16"(49)

2-1/16"(52)

2-3/16"(56)

2-1/2"(64)

2-5/8"(67)

2-1/8"(54)

2-1/4"(57)

2-3/8"(60)

2-5/8"(67)

2-3/4"(70)

2-3/16"(56)

2-9/32"(58)

7/16"(11)

2-5/8"(67)

2-3/4"(70)

Locknut Bushing Conduit

1-1/8"(29)

1-3/8"(35)

1-11/16"(43)

2-3/16"(56)

2-7/16"(62)

Locknut Bushing Conduit

1"(25)

1-1/4"(32)

1-1/2"(38)

1-7/8"(48)

2-1/8"(54)

Locknut Bushing Conduit

7/8"(22)

1-1/16"(27)

1-3/8"(35)

1-11/16"(43)

1-15/16"(49)

1 Minimum spacing required to provide clearance over locknuts and bushings.

2 Preferred—more liberal spacings between centers of conduits to be used whenever possible.
3 GU—spacing required for GU Series unions.

4 Union hubs are supplied by using a drilled and tapped opening with GUM Series Union.

SYMBOL NUMBERS
CONDUIT
SIZE
1/2"

CONDUIT OPENINGS
DRILLED
UNION4
AND TAPPED
1
11

3/4"

2

12

1"

3

13

1-1/4"

4

14

1-1/2"

5

15

† Consult factory for special or additional conduit sizes, locations, and combinations
required but not illustrated.

C21

XCS SERIES • CONTROLS
C O V E R A S S E M B L I E S • C O N T R O L S TAT I O N S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Listed - File E53360

Single
Push Button

Three
Mini-Push Button

Double
Push Button

Push-Pull
Mushroom Maintained
Push Button

Certified - File LR11714
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
X C S M O M E N TA R Y C O N TA C T S I N G L E P U S H B U T T O N

COVER WITH DEVICE
XCS-0B1
XCS-0B2
XCS-0B3

CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

HUB
SIZE

XCS-1B1

XCS-4B1

1/2"

XCS-2B1

XCS-5B1

3/4"

XCS-1B2

XCS-4B2

1/2"

XCS-2B2

XCS-5B2

3/4"

BUTTON
COLOR 2

DIAGRAM

NAMEPLATE
MARKING1

Green

Start

••

Red

Stop

Black

Specify

••

XCS-1B3

XCS-4B3

1/2"

XCS-2B3

XCS-5B3

3/4"

••
••

HUB
SIZE

DIAGRAM

X C S M O M E N TA R Y C O N TA C T D O U B L E P U S H B U T T O N

COVER WITH DEVICE
XCS-0B4
XCS-0B4-U
XCS-0B5
XCS-0B7

CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU
XCS-1B4

XCS-4B4

1/2"

XCS-2B4

XCS-5B4

3/4"

XCS-1B4-U

XCS-4B4-U

1/2"

XCS-2B4-U

XCS-5B4-U

3/4"

BUTTON
COLOR 2

NAMEPLATE
MARKING1

••

Green-Red

Start/Stop

••
••

••
••

Green-Red

Start/Stop

••

XCS-1B5

XCS-4B5

1/2"

XCS-2B5

XCS-5B5

3/4"

••

••

Green-Green

Start/Start

XCS-1B7

XCS-4B7

1/2"

XCS-2B7

XCS-5B7

3/4"

••
••

••
••

Black-Black

Specify

X C S M O M E N TA R Y C O N TA C T T H R E E M I N I P U S H B U T T O N S

COVER WITH DEVICE
XCS-0A8
XCS-0A9

CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

HUB
SIZE

XCS-1A8

XCS-4A8

1/2"

XCS-2A8

XCS-5A8

3/4"

XCS-1A9

XCS-4A9

1/2"

XCS-2A9

XCS-5A9

3/4"

BUTTON
COLOR 2

DIAGRAM

••
••
••

••

••
••

••
••

••
••

NAMEPLATE
MARKING1

Green-Red

Start/Stop

Black

Specify

Black

Specify

1 For other than standard marking, refer to the special feature section of price list.
2 Lens colors other than listed may be specified by changing lens color suffix. See modifications page C18.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
X C S M A I N TA I N E D C O N TA C T P U S H P U L L M U S H R O O M P U S H B U T T O N 4
CATALOG NUMBER (COVER WITH DEVICE)

DIAGRAM

XCS-OMMG3
XCS-OMMR3
XCS-OMMK3

••

••

BUTTON COLOR
GREEN
RED

NAMEPLATE MARKING
3

BLACK

3 Three nameplates supplied (Start/Stop, Blank, Emergency Stop) with XCS maintained push button.
4 Operation - when push button is depressed and contact activated, operator will remain in depressed
position until pulled out in normal position.

C

C22

XCS SERIES • CONTROLS
C O V E R A S S E M B L I E S • C O N T R O L S TAT I O N S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Listed - File E53360

Pilot Light

Double
Pilot Light

Pilot Light
Push Button

Certified - File LR11714

Pilot Light
Two Mini Push Buttons

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
XCS PILOT LIGHT3
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU
XCS-0B24CL
XCS-0B24GL
XCS-0B24RL

HUB
SIZE

XCS-1B24CL

XCS-4B24CL

1/2"

XCS-2B24CL

XCS-5B24CL

3/4"

XCS-1B24GL

XCS-4B24GL

1/2"

XCS-2B24GL

XCS-5B24GL

3/4"

XCS-1B24RL

XCS-4B24RL

1/2"

XCS-2B24RL

XCS-5B24RL

3/4"

DIAGRAM

LAMP
VOLTS

LENS
COLOR2

NAMEPLATE
MARKING1

120V

Clear

Specify

120V

Green

Specify

120V

Red

Specify

XCS DOUBLE PILOT LIGHT4
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU
XCS-0B30CL
XCS-0B30GL
XCS-0B30RL
XCS-0B30RL-GL

HUB
SIZE

XCS-1B30CL

XCS-4B30CL

1/2"

XCS-2B30CL

XCS-5B30CL

3/4"

XCS-1B30GL

XCS-4B30GL

1/2"

XCS-2B30GL

XCS-5B30GL

3/4"

XCS-1B30RL

XCS-4B30RL

1/2"

XCS-2B30RL

XCS-5B30RL

3/4"

XCS-1B30RL-GL

XCS-4B30RL-GL

1/2"

XCS-2B30RL-GL

XCS-5B30RL-GL

3/4"

LAMP
VOLTS

DIAGRAM

LENS
COLOR2

NAMEPLATE
MARKING1

120V

Clear

Specify

120V

Green

Specify

120V

Red

Specify

120V

Red/Green

Specify

X C S M O M E N TA R Y C O N TA C T P U S H B U T T O N A N D P I L O T L I G H T 4
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU
XCS-0B13-C
XCS-0B13-O
XCS-0B13-U

HUB
SIZE

XCS-1B13-C

XCS-4B13-C

1/2"

XCS-2B13-C

XCS-5B13-C

3/4"

XCS-1B13-O

XCS-4B13-O

1/2"

XCS-2B13-O

XCS-5B13-O

3/4"

XCS-1B13-U

XCS-4B13-U

1/2"

XCS-2B13-U

XCS-5B13-U

3/4"

DIAGRAM

••
••
••
••

BUTTON
COLOR

LENS
COLOR2

NAMEPLATE
MARKING1
BUTTON

LENS

Red

Red

Stop

Specify

Green

Red

Start

Specify

Black

Red

Specify

Specify

X C S M O M E N TA R Y C O N TA C T T W O M I N I P U S H B U T T O N S A N D P I L O T L I G H T 4
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER)
COVER WITH DEVICE
DEAD-END
FEED-THRU

HUB
SIZE

XCS-1A15

XCS-4A15

1/2"

XCS-2A15

XCS-5A15

3/4"

XCS-0A15

DIAGRAM

••

••

120 VAC

BUTTON
COLOR

LENS
COLOR 2

Red

NAMEPLATE
MARKING 1
BUTTON

Red
Green

LENS

Stop
Specify
Start

1 For other than standard marking, refer to the special feature section of price list.
2 Lens color suffix listed in modifications page C18. Unless different lens colors are specified by proper suffix catalog number, red lens will be provided.
3 Pilot light transformers also listed in modifications. Add suffix to cover assembly catalog number.
4 Pilot light transformers will not fit in these assemblies. When transformer is desired, use SWB-14, indicating conduit openings required from chart on
page C20 of this section. See page C18 for required transformer suffix. One transformer required for each lamp.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover and box as separate components.

C23

XCS SERIES • CONTROLS
C O V E R A S S E M B L I E S • C O N T R O L S TAT I O N S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7 (C,D) 9(E,F,G)
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.

Key Operated

Selector Switch

F E AT U R E S - S P E C I F I C AT I O N S
X C S T W O P O S I T I O N S E L E C T O R S W I T C H ( M A I N TA I N E D ) *
CATALOG NUMBER
COVER WITH
DEVICE
XCS-0S2A1
XCS-0S2A52

COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

HUB
SIZE

XCS-1S2A1

XCS-4S2A1

1/2"

XCS-2S2A1

XCS-5S2A1

3/4"

XCS-42S2A5

XCS-45S2A5

3/4"

TWO POSITION DIAGRAM
LEFT POSITION
RIGHT POSITION
LEFT
BLOCKS

••
••
••

RIGHT
BLOCKS

LEFT
BLOCKS

••

••
••
••

••
••

NAMEPLATE
MARKING 1

RIGHT
BLOCKS

••

OFF/ON

••
••

OFF/ON

X C S T H R E E P O S I T I O N S E L E C T O R S W I T C H ( M A I N TA I N E D ) *
CATALOG NUMBER
COVER WITH
DEVICE
XCS-0S3C4
XCS-0S3C52

COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

HUB
SIZE

XCS-1S3C4

XCS-4S3C4

1/2"

XCS-2S3C4

XCS-5S3C4

3/4"

XCS-42S3C5

XCS-45S3C5

3/4"

LEFT POSITION
LEFT
RIGHT
BLOCKS
BLOCKS

••
••
••

1 For other than standard marking, refer to the special feature section of the price list.

THREE POSITION DIAGRAM
CENTER POSITION
RIGHT POSITION
LEFT
RIGHT
LEFT
RIGHT
BLOCKS
BLOCKS
BLOCKS
BLOCKS

••

••

••
••
••

••
••

••
••
••

••
••

NAMEPLATE
MARKING

••

HOA

••
••

HOA

C

2These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49.

For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
X C S T W O P O S I T I O N K E Y O P E R AT E D S E L E C T O R S W I T C H ( M A I N TA I N E D ) *
CATALOG NUMBER
COVER WITH
DEVICE
XCS-0K2A1D
XCS-0K2A5D2

COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

HUB
SIZE

TWO POSITION DIAGRAM
LEFT POSITION
RIGHT POSITION
LEFT
RIGHT
LEFT
RIGHT
BLOCKS
BLOCKS
BLOCKS
BLOCKS

XCS-1K2A1D

XCS-4K2A1D

1/2"

XCS-2K2A1D

XCS-5K2A1D

3/4"

••

XCS-42K2A5D

XCS-45K2A5D

3/4"

••
••

••

••

••
••

••
••

NAMEPLATE
MARKING1

••

OFF/ON

••
••

OFF/ON

X C S T H R E E P O S I T I O N K E Y O P E R AT E D S E L E C T O R S W I T C H ( M A I N TA I N E D ) *

XCS-0K3C5D2

XCS-1K3C4D

XCS-4K3C4D

1/2"

XCS-2K3C4D

XCS-5K3C4D

3/4"

••

••

XCS-42K3C5D

XCS-45K3C5D

3/4"

••
••

••
••

THREE POSITION DIAGRAM
CENTER POSITION
RIGHT POSITION
LEFT
RIGHT
LEFT
RIGHT
BLOCKS
BLOCKS
BLOCKS
BLOCKS

••
••
••

••

XCS-0K3C4D

COMPLETE UNITS (BOX & COVER)
DEAD-END
FEED-THRU

LEFT POSITION
LEFT
RIGHT
BLOCKS
BLOCKS

••
••

NAMEPLATE
MARKING

••

COVER WITH
DEVICE

HUB
SIZE

••

CATALOG NUMBER

HOA

••
••

••
••

HOA

1For other than standard marking, refer to the special feature section of the price list.
2These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
* Key removal in all positions for 2 & 3 position key operated selectors. Consult factory for variations.

C24

XCS SERIES • CONTROLS
C O V E R A S S E M B L I E S • C O N T R O L S TAT I O N S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7 (C,D) 9(E,F,G)
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.

Selector Switch

F E AT U R E S - S P E C I F I C AT I O N S
XCS SPRING RETURN SELECTOR SWITCH
Tw o P o s i t i o n S p r i n g R e t u r n t o L e f t
CATALOG NUMBER
COVER WITH
DEVICE1
XCS-0S2L3F

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42S2L3F

XCS-45S2L3F

HUB
SIZE

TWO POSITION DIAGRAM
RIGHT POSITION
LEFT
RIGHT
RIGHT
BLOCK
BLOCK
BLOCK

LEFT POSITION
LEFT
BLOCK

3/4"

••

••

••

••

XCS SPRING RETURN SELECTOR SWITCH
Three Position Spring Return to Center From Right and Left
CATALOG NUMBER
COVER WITH
DEVICE1
XCS-0S3M6G

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42S3M6G

XCS-45S3M6G

HUB
SIZE

3/4"

LEFT POSITION
LEFT
BLOCK

RIGHT
BLOCK

••

••

THREE POSITION DIAGRAM
CENTER POSITION
RIGHT
LEFT
BLOCK
BLOCK

••

••

RIGHT POSITION
RIGHT
LEFT
BLOCK
BLOCK

••

••

XCS SPRING RETURN SELECTOR SWITCH
Three Position Spring Return to Center From Right, Maintain in Left
CATALOG NUMBER
COVER WITH
DEVICE1
XCS-0S3L6G

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42S3L6G

XCS-45S3L6G

HUB
SIZE

3/4"

LEFT POSITION
LEFT
BLOCK

RIGHT
BLOCK

••

••

THREE POSITION DIAGRAM
CENTER POSITION
LEFT
BLOCK

••

RIGHT
BLOCK

••

RIGHT POSITION
LEFT
BLOCK

RIGHT
BLOCK

••

••

XCS SPRING RETURN SELECTOR SWITCH
Three Position Spring Return to Center From Left, Maintain in Right
CATALOG NUMBER
COVER WITH
DEVICE1
XCS-0S3R6G

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42S3R6G

XCS-45S3R6G

HUB
SIZE

3/4"

LEFT POSITION

THREE POSITION DIAGRAM
CENTER POSITION

RIGHT POSITION

LEFT
BLOCK

RIGHT
BLOCK

LEFT
BLOCK

RIGHT
BLOCK

LEFT
BLOCK

RIGHT
BLOCK

••

••

••

••

••

••

1 All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.

C25

XCS SERIES • CONTROLS
C O V E R A S S E M B L I E S • C O N T R O L S TAT I O N S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7 (C,D) 9(E,F,G)
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.

Key Operated

F E AT U R E S - S P E C I F I C AT I O N S
X C S K E Y O P E R AT E D S P R I N G R E T U R N S E L E C T O R S W I T C H 1
Tw o P o s i t i o n S p r i n g R e t u r n t o L e f t
CATALOG NUMBER
COVER WITH
DEVICE2
XCS-0K2L3F22D

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42K2L3F22D

XCS-45K2L3F22D

HUB
SIZE

LEFT POSITION
LEFT
BLOCK

3/4"

••

TWO POSITION DIAGRAM
RIGHT POSITION

RIGHT
BLOCK

LEFT
BLOCK

RIGHT
BLOCK

••

••

••

X C S K E Y O P E R AT E D S P R I N G R E T U R N S E L E C T O R S W I T C H 1
Three Position Spring Return to Center From Right and Left
CATALOG NUMBER
COVER WITH
DEVICE2
XCS-0K3M6G32D

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42K3M6G32D

XCS-45K3M6G32D

HUB
SIZE

3/4"

LEFT POSITION
LEFT
BLOCK

RIGHT
BLOCK

••

••

THREE POSITION DIAGRAM
CENTER POSITION
LEFT
BLOCK

••

RIGHT
BLOCK

••

RIGHT POSITION
LEFT
BLOCK

RIGHT
BLOCK

••

••

C

X C S K E Y O P E R AT E D S P R I N G R E T U R N S E L E C T O R S W I T C H 1
Three Position Spring Return to Center From Right, Maintain in Left
CATALOG NUMBER
COVER WITH
DEVICE2
XCS-0K3L6G32D

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42K3L6G32D

XCS-45K3L6G32D

HUB
SIZE

3/4"

LEFT POSITION
LEFT
BLOCK

RIGHT
BLOCK

••

••

THREE POSITION DIAGRAM
CENTER POSITION
RIGHT
LEFT
BLOCK
BLOCK

••

••

RIGHT POSITION
RIGHT
LEFT
BLOCK
BLOCK

••

••

X C S K E Y O P E R AT E D S P R I N G R E T U R N S E L E C T O R S W I T C H 1
Three Position Spring Return to Center From Left, Maintain in Right
CATALOG NUMBER
COVER WITH
DEVICE2
XCS-0K3R6G32D

COMPLETE UNITS (BOX & COVER)
FEED-THRU
DEAD-END
XCS-42K3R6G32D

XCS-45K3R6G32D

HUB
SIZE

3/4"

LEFT POSITION
LEFT
BLOCK

RIGHT
BLOCK

••

••

THREE POSITION DIAGRAM
CENTER POSITION
RIGHT
LEFT
BLOCK
BLOCK

••

••

RIGHT POSITION
RIGHT
LEFT
BLOCK
BLOCK

••

••

1 All key operators are furnished keyed different.
If keyed alike is required substitute letter “A” for “D” at end of catalog number.
Keys are removable in left position selectors and in center position for 3 position selectors.
For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
2 All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box
as separate components.

C26

SEAL X/XCS SERIES • CONTROLS
B L A N K A C C E S S O R I E S / R E P L A C E M E N T PA R T S

Standard
Push Button
(Mushroom)

X-10
Blank Cover

S TA N D A R D P U S H B U T T O N A S S E M B LY
(1-3/8” DIAMETER)

X BLANK AND SPECIAL COVERS
CAT. NO.

M I N I AT U R E P U S H B U T T O N A S S E M B LY
(3/4” DIAMETER)

DESCRIPTION
C ATA L O G N U M B E R

X-10

Blank cover

X-60

Cover with (1) 3/4" NPSM Hole1

X-64

Miniature
Push Button

Cover with (2) 3/4" NPSM Holes1 2

1 For “G” series short operators.
2 When X-64 cover is used, one operator
must be a pilot light due to electrical clearances.

SHROUD

RED

GREEN

BLACK

RED

GREEN

BLACK

XO1BR

XO1BG

XO1BK

XO1AR

XO1AG

XO1AK

Full

XO3BR

XO3BG

XO3BK

XO3AR

XO3AG

XO3AK

Half

XO5BR

—

—

—

—

—

Mushroom*

*1-1/2” diameter

Pilot Light
X C S P I L O T L I G H T O P E R AT O R A S S E M B LY 1
CATALOG NUMBER

SHROUD

RED

GREEN

CLEAR

AMBER

XO21BR

XO21BG

XO21BC

XO21BA

Miniature
Lockout

Standard
Lockout

Selector
Lockout

Standard

Hole Plug

Dust/Weather
Cap

C ATA L O G N U M B E R G O M L O C K

ACCESSORIES
CATALOG NUMBER
PUSH BUTTON1
LOCKOUT

GOM Lockout

DESCRIPTION

SELECTOR
LOCKOUT1

HOLE
PLUG1

DUST/WEATHER CAP
RED
GREEN
BLACK

XLOB

G0-567-LOK

XOBP

XDBR

XDBG

XDBB

Standard operator

XLOA

—

XOAP

—

—

—

Miniature operator

XCS-OMMR3

1 Replacement only by qualified person. Operator is staked into position at factory.
Removal may damage operator or cover threads.
X C S R E P L A C E M E N T B L A N K N A M E P L AT E S
CATALOG NUMBER

LOCKOUT FOR MAINTAINED
PUSH BUTTON COVERS

DESCRIPTION

XCSNPPB

XCS/FXCS full size (standard) push button

XCSNPPBM

XCS/FXCS miniature push button

XCSNPPL

XCS/FXCS pilot light

XCSNPSS2

XCS/FXCS 2 position selector switch

XCSNPSS3

XCS/FXCS 3 position selector switch

FXCS-OMMR3

C27

SEAL X/XCS SERIES • CONTROLS
A C C E S S O R I E S / R E P L A C E M E N T PA R T S

Incandescent
Filament Lamp

Contact Block

INCANDESCENT LAMP
CANDELABRA SCREW BASE

S TA N D A R D C O N TA C T B L O C K S

CAT. NO.

VOLT

COLOR

0460051B

120V AC/DC

CLEAR

0460414B

24V AC/DC

CLEAR

CAT. NO.

DESCRIPTION

GO-8672-BJK

1 N.O.

GO-8672-BJJ

1 N.O.

GO-8672-BJH

1 N.O. Early Make

GO-8672-BJE

1 N.C. Late Make

C O N TA C T B L O C K S F O R X C S S E R I E S
C ATA L O G N U M B E R S E N D I N G W I T H
B4-U, B7, A8 OR A9

LED Lamp
XCS-FXCS LED LAMPS
CAT. NO.

VOLT

COLOR

XCSLED-R110

120 VAC

RED

XCSLED-G110

120 VAC

GREEN

XCSLED-A110

120 VAC

AMBER

CAT. NO.

DESCRIPTION

YOWE-OT2B

1 N.O.

YOWE-OT2D

1 N.C.

C O N TA C T B L O C K F O R F X C S S E R I E S
C ATA L O G N U M B E R S E N D I N G W I T H
B-13U
CAT. NO.

DESCRIPTION

GO-8672-PTCH

(1) N.O. (1) N.C.

C
C O N TA C T B L O C K F O R F X C S S E R I E S
C ATA L O G N U M B E R S E N D I N G W I T H
B4-U, B7, A5, C5

Incandescent
Filament Lamp

LED Lamp

XCS-FXCS LAMPS
CAT. NO.

LAMP TYPE

VOLTS AC/DC

YOSY24MB

FILAMENT

24

COLOR
CLEAR

YOSY120MB

FILAMENT

120

CLEAR

GOLED-A110

LED

110

AMBER

GOLED-G110

LED

110

GREEN

GOLED-R110

LED

110

RED

GOLED-A24

LED

24

AMBER

GOLED-G24

LED

24

GREEN

GOLED-R24

LED

24

RED

CAT. NO.

DESCRIPTION

GO-8672-PTCC

(2) N.O. (2) N.C.

C28

XS SERIES • CONTROLS
TUMBLER SWITCH

Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Listed - FILE E53360
Certified - File LR11712
FM
APPROVED

XS-3C

File OP7A5.AE
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Applications
Used where making, breaking, or
changing connections in an electric circuit are required.
Features
XS Series are front lever rotary operated switch assemblies with standard
provisions for padlocking in either “ON”
or “OFF” position. The lever is connected to a threaded stainless steel shaft
which passes through the cover.

XS TUMBLER SWITCH
COVER
WITH
WITHOUT
DEVICE
DEVICE
XS-1C

XNS-1C

XS-2C

XNS-2C

XS-8C

XNS-8C

XS-3C

XNS-3C

XS-5C

XNS-5C

XS-6C

XNS-6C

XS-7C

XNS-7C

XS-1D

XNS-1D

XS-2D

XNS-2D

XS-4C

—

CATALOG NUMBER
COMPLETE UNITS
HUB
(BOX, COVER AND SWITCH)
SIZE
DEAD-END FEED-THRU
1/2"
XS-11C
XS-41C
3/4"
XS-21C
XS-51C
1/2"
XS-12C
XS-42C
3/4"
XS-22C
XS-52C
1/2"
XS-18C
XS-48C
3/4"
XS-28C
XS-58C
1/2"
XS-13C
XS-43C
3/4"
XS-23C
XS-53C
1/2"
XS-15C
XS-45C
3/4"
XS-25C
XS-55C
1/2"
XS-16C
XS-46C
3/4"
XS-26C
XS-56C
1/2"
XS-17C
XS-47C
3/4"
XS-27C
XS-57C
1/2"
XS-11D
XS-41D
3/4"
XS-21D
XS-51D
1/2"
XS-12D
XS-42D
3/4"
XS-22D
XS-52D
—
—
—

SWITCH
STYLE

SWITCH RATING
120/277 VAC, 1Ø

1-POLE

20A2

2-POLE

20A2

3-POLE

1

3-WAY/
SPDT No center off
SPDT
Center off
DPDT
No center off
DPDT
Center off

20A2

1-POLE

30A2

2-POLE

30A2

4-WAY

20A2

1 Rated 15 amperes, 240/480 VAC., 3Ø: 3HP-240 VAC., 5 HP-480 VAC.
2 Horsepower rated 1 HP at 120VAC, 2 HP at 240VAC.

20A2
20A2
20A2

C29

XAL/XAS SERIES • CONTROLS
F I R E A L A R M S TAT I O N S

Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)

XAS
Break Glass

XAL
Pull Ring

F E AT U R E S - S P E C I F I C AT I O N S
Applications
• Hazardous areas due to the presence of flammable gases or vapors,
combustible dusts or easily ignitable
fibers or flyings
• Installation at petroleum refineries,
chemical and petrochemical plants,
storage areas, and other processing
facilities where hazardous substances are handled or stored
• Areas where emergency control of
fire alarm or signal circuits is required
Features
• Enclosure is made of copper free aluminum alloy
• Conduit openings are 3/4" NPT feed
through
• Red, textured powder epoxy paint
finish is standard on box and cover
and provides high visibility for alarm
station
• XAL-458 has (2) normally open and
(2) normally closed contacts.
• Bilingual nameplates included per
CSA requirement
• Internal ground screw is standard

Operation
XAL: The alarm station is activated by
lifting the front cover and pulling down
ring. This quick, easy to use two-step
process prevents unintentional operation. Operator is reset by depressing
shaft and returning plate to original
position.

XAS: Breaking glass with hammer provided activates alarm. Reset by replacing glass.
Replacement glass catalog number
YOKK-15214.
Replacement hammer and chain
KIT-232.

XAL Series:

XAS Series:
Listed - File E50498

Listed - File E50498

Certified - File LR31085
See files for details or call Killark.

Listed - CE69
Certified - File LR31085
Listed - California State Fire Marshall
#7150-1439:100
X A L F I R E A L A R M S TAT I O N
CATALOG NUMBER

OPERATION TYPE

CONTACT BLOCKS

XAL-53

Pull ring

(1) NO/NC

XAL-458

Pull ring

(2) NO/NC

XAS-53

Break glass

(1) NO/NC

C

C O N TA C T B L O C K R AT I N G
AC
VOLTS

MAKE
AMPERES

VA

DC

BREAK
AMPERES

VA

CONTINUOUS
CARRYING
AMPERES

VOLTS

MAKE
BREAK

CONTINUOUS
CARRYING
AMPERES

120

60

7200

6

720

10

125

1.1

2.5

240

30

7200

3

720

10

250

0.55

2.5

480

15

7200

1.5

720

10

600

0.2

2.5

600

12

7200

1.2

720

10

—

—

—

Dimensions

XAL-53
Note: On XAL-458 the overall depth is 5-9/16”

XAS-53

C30

G SERIES • CONTROLS
C U S T O M C O N T R O L PA N E L O P E R AT O R S I N T R O D U C T I O N

Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart below
F E AT U R E S - S P E C I F I C AT I O N S
Applications
G Series custom control panel operators are designed for use in hazardous
locations when installed in suitable
enclosures such as B7E EXB, XJB, DB,
SWB and GCS Series boxes and B7,
Y7 Starter Enclosures.
Features
• Operators are all aluminum except
for certain movable parts which are
stainless steel, all other parts such as
screws are either stainless steel or
plated steel
• Threaded bodies are all 3/4"-14
NPSM thread
• Control stations can be grouped into
a single assembly thus reducing
installation time and cost
• Junction boxes may be used to
mount operators along with glass
lens for viewing internally mounted
meters. Additional relays, timers, terminal blocks, or other equipment
may also be internally mounted to
provide a single centralized control
unit.
• Custom operators other than
standard assemblies listed may be
ordered by proper catalog number
from custom operator ordering
system pages C40 & C41
Electrical Rating
Push button stations, selector switches
Heavy duty 600 VAC max.
Pilot lights 120 VAC.
Dimensions
See Dimensional information for
G Series operators on page C42.

Recommended Operator Selection
Short Style
DB/SWB/GCS Enclosures. Assemblies
with wall thickness up to 1/2" thick.
Long Style
All B7E/XJB Enclosures. EXB (see page
E12) enclosures with cover thickness
up to 1-1/2” thick.

potentiometer operators are CENELEC/ATEX EExd IIB+H2 when installed
in series EXB*CEN and GR*CEN enclosures.
For pilot lights and illuminated push buttons in CENELEC/ATEX applications see
page C33.

Extended Style
EXB larger size enclosures (see page
E12) with cover thickness up to 2-1/2”
thick.
Killark long and extended push buttons, selector switches, reset and
C O N TA C T B L O C K R AT I N G S
CURRENT
Inrush

120 VAC

240 VAC

60

30

Breaking

6

3

Carr ying

10

10

480 VAC

600 VAC

15

125 VDC

12

1.5

1.2

10

10

250 VDC

.55

.275

.55

.275

2.50

2.50

Note: Contact blocks can be stacked four deep maximum.

A R E A C L A S S I F I C AT I O N C H A R T F O R O P E R AT O R S
GO14

GO172

GO302

GO572

GOL24

GOL383

GO54

GO192

GO352 GO363

GO592

GOL44

GOL1133

GO24
GO64
GO74
GO83

GO104
GO144
GO154
GO162

1 Class
2 Class
3 Class
4 Class
5 Class

GO182
GO212
GO222
GO232
GO252
GO262
GO272
GO282

GO342

GO373
GO383
GO393
GO401
GO502
G0512

GO562

GO582
GO1133
GO1143
GO1332
GO1342
GOB34
GOB44
GOL14

GOL34
GOL54
GOL64

GOL74 GOL83
GOL144
GOL154
GOL363
GOL374

GOL393

GOL1143

GOLRST4
GOM15

GOR114

GORST4

GO113882
GO113722

II Div. 1 & 2 Group EFG NEMA 9EFG
I Div. 1 & 2 Group CD, Class II Div. 1 & 2 Group EFG, Class III NEMA 7CD, 9EFG
I Div. 1 & 2 Group BCD, Class II Div. 1 & 2 Group EFG, Class III NEMA 3, 4, 7BCD, 9EFG
I Div. 1 & 2 Group BCD, Class II Div. 1 & 2 Group EFG, Class III NEMA 3, 4, 4X, 7BCD, 9EFG
I Div. 1 & 2 Group CD, Class II Div. 1 & 2 Group EFG, Class III NEMA 3, 4, 7CD, 9EFG

C31

G SERIES • CONTROLS
PUSH BUTTONS

Single Push Button
Long

Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)

Single Push Button
Extended

See Area Classification Chart
page C40 for Details
Listed - File E12379

“G” Series Operator
Maintained

Certified - File LR11714
See files for details or call Killark.

Double Push Button

F E AT U R E S - S P E C I F I C AT I O N S
G S I N G L E P U S H B U T T O N ( M O M E N TA R Y C O N TA C T )
SHORT4

CATALOG NUMBER1
LONG

EXTENDED

COLOR

GO21-GZ1B

GO1-GX1B N34

GOL1G1

Green

GO21-KZ1C

GO1-KX1C N34

GOL1K1

Black

GO21-RZ2B

GO1-RX2B N34

GOL1R2

Red

GO21-KZ2C

GO1-KX2C N34

GOL1K2

Black

GO21-GZ3C

GO1-GX3C N34

GOL1G3

Green

GO21-RZ3C

GO1-RX3C N34

GOL1R3

Red

GO21-KZ3C

GO1-KX3C N34

GOL1K3

Black

GO21-GZ0C

GO1-GX0C N34

GOL1G

Green

GO21-RZ0C

GO1-RX0C N34

GOL1R

Red

GO21-KZ0C

GO1-KX0C N34

GOL1K

Black

CONTACT TYPE3

NAMEPLATE MARKING2
Start or Stop

••

Reset or Blank
Start or Stop

••

Reset or Blank
Reset or Blank

••
••

Reset or Blank
Reset or Blank
Reset or Blank

None

Reset or Blank
Reset or Blank

G S I N G L E P U S H B U T T O N ( M A I N TA I N E D C O N TA C T ) M U S H R O O M H E A D P U S H - P U L L O P E R AT I O N
GOM21-GM3C

GOM1-GM3C N34

GOML1G3

Green

GOM21-RM3C

GOM1-RM3C N34

GOML1R3

Red

GOM21-KM3C

GOM1-KM3C N34

GOML1K3

Black

GOM21-GM0C

GOM1-GM0C N34

GOML1G

Green

GOM21-RM0C

GOM1-RM0C N34

GOML1R

Red

GOM21-KM0C

GOM1-KM0C N34

GOML1K

Black

Blank

••
••

Blank
Blank
Blank

None

Blank
Blank

G D O U B L E P U S H B U T T O N ( M O M E N TA R Y C O N TA C T )
GO22-GR12D

G02-GR12D N34

GOL2GR12

Green/Red

GO22-KK12D

G02-KK12D N34

GOL2KK12

Black/Black

GO22-GR33D

G02-GR33D N34

GOL2GR33

Green/Red

GO22-KK33D

G02-KK33D N34

GOL2KK33

Black/Black

GO22-GR00D

G02-GR00D N34

GOL2GR

Green/Red

GO22-KK00D

G02-KK00D N34

GOL2KK

Black/Black

••

••

••
••

••
••

Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank

None

Start/Stop or Blank

G D O U B L E P U S H B U T T O N ( M A I N TA I N E D C O N TA C T ) 5
—

GOR11-GR6D N34

—

Green/Red

—

GOR11-GR7D N34

—

—

GOR11-GR8D N34
GOR11-GR0D N34

—

Start/Stop or Blank

••

••

Green/Red

••

••

Start/Stop or Blank

—

Green/Red

••
••

••
••

Start/Stop or Blank

—

Green/Red

None

Start/Stop or Blank

1 Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for accessories, page C30 for complete details on
Area Classification of operators, page C42 for Dimensional information.
2 Nameplates are double sided.
3 Contact Blocks are shown in their normal position.
4 Short style operators are suitable for Class l Group C & D, Class ll Group E,F,G only.
5 When pressed, the green button will remain in a depressed position. Pressing red button releases green from the depressed position.

C

C32

GS SERIES • CONTROLS
PILOT LIGHTS

Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
Listed - File E12379
Certified - File LR11714

Pilot Light

Illuminated Button

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S

G PILOT LIGHTS
SHORT 4
GO23-A23C

CATALOG NUMBER 1
LONG
GOB3-A23C N34

EXTENDED
GOL3A

COLOR

CONTACT TYPE 3

NAMEPLATE MARKING 2
Blank

Amber

Blank

GO23-B23C

GOB3-B23C N34

GOL3B

Blue

GO23-C23C

GOB3-C23C N34

GOL3C

Clear

GO23-F23C

GOB3-F23C N34

GOL3F

Frosted

GO23-G23C

GOB3-G23C N34

GOL3G

Green

Blank

GO23-R23C

GOB3-R23C N34

GOL3R

Red

Blank

110-120 Volts
Full Volts

Blank
Blank

G P I L O T L I G H T S W I T H L E D 1 1 0 V O LT L A M P S
—

GOB3-A23C N34 LED

GOL3A LED

Amber

—

GOB3-G23C N34 LED

GOL3G LED

Green

—

GOB3-R23C N34 LED

GOL3R LED

Red

110-120 Volts
Full Volts (LED)

Blank
Blank
Blank

G I L L U M I N AT E D B U T T O N O R P U S H T O T E S T P I L O T L I G H T
—

GOB4-A233C N34

GOL4A3

Amber

—

GOB4-B233C N34

GOL4B3

Blue

—

GOB4-C233C N34

GOL4C3

Clear

—

GOB4-F233C N34

GOL4F3

Frosted

—

GOB4-G233C N34

GOL4G3

Green

—

GOB4-R233C N34

GOL4R3

Red

—

GOB4-A230C N34

GOL4A

Amber

—

GOB4-B230C N34

GOL4B

Blue

—

GOB4-C230C N34

GOL4C

Clear

—

GOB4-F230C N34

GOL4F

Frosted

—

GOB4-G230C N34

GOL4G

Green

—

GOB4-R230C N34

GOL4R

Red

110-120 Volts
Full Volts

Blank
Blank
Blank
Blank

••
••

Blank
Blank
Blank

110-120 Volts

Blank
Blank

No Contact
Blocks

Blank
Blank
Blank

G I L L U M I N AT E D B U T T O N O R P U S H T O T E S T P I L O T L I G H T W I T H L E D 1 1 0 V O LT L A M P S
—

GOB4-A233C N34 LED

GOL4A3 LED

Amber

—

GOB4-G233C N34 LED

GOL4G3 LED

Green

—

GOB4-R233C N34 LED

GOL4R3 LED

Red

—

GOB4-A230C N34 LED

GOL4A LED

Amber

—

GOB4-G230C N34 LED

GOL4G LED

Green

—

GOB4-R230C N34 LED

GOL4R LED

Red

Blank
110-120 Volts
Full Volts (LED)

••
••

110-120 Volts (LED)
No Contact Blocks

Blank
Blank
Blank
Blank
Blank

1Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for accessories, page C30 for com

plete details on Area Classification of operators, page C42 for Dimensional information.

2Nameplates are double sided.

3Contact Blocks are shown in their normal position.

4Short style operators are suitable for Class l Group C & D, Class ll Group E,F,G only.

C33

G SERIES • CONTROLS
P I L O T L I G H T S F O R AT E X / C E N E L E C A P P L I C AT I O N S

Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups llB+H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
ATEX-EExd IIB + H2
Listed - File E12379
Certified - File LR11714

Pilot Light ATEX

Illuminated Push Button ATEX
P T B N o . 0 3 AT E X 1 2 0 3 U

F E AT U R E S - S P E C I F I C AT I O N S
G PILOT LIGHTS
CATALOG NUMBER1
LONG
GOB3-A23C N34CN

EXTENDED
GOL3ACN

COLOR

CONTACT TYPE 3

NAME PLATE MARKING2

Amber

Blank

GOB3-B23C N34CN

GOL3BCN

Blue

GOB3-C23C N34CN

GOL3CCN

Clear

GOB3-F23C N34CN

GOL3FCN

Frosted

GOB3-G23C N34CN

GOL3GCN

Green

Blank

GOB3-R23C N34CN

GOL3RCN

Red

Blank

Blank
1 1 0 - 1 2 0 Vo l t s
F u l l Vo l t s

Blank
Blank

G P I L O T L I G H T S W I T H L E D 1 1 0 V O LT L A M P S
GOB3-A23C N34LEDCN

GOL3ALEDCN

Amber

GOB3-G23C N34LEDCN

GOL3GLEDCN

Green

GOB3-R23C N34LEDCN

GOL3RLEDCN

Red

1 1 0 - 1 2 0 Vo l t s
F u l l Vo l t s ( L E D )

Blank
Blank
Blank

G I L L U M I N AT E D P U S H B U T T O N O R P U S H T O T E S T P I L O T L I G H T
GOB4-A233CN34CN

GOL4A3CN

GOB4-B233CN34CN

GOL4B3CN

Blue

GOB4-C233CN34CN

GOL4C3CN

Clear

GOB4-F233CN34CN

GOL4F3CN

Frosted

GOB4-G233CN34CN

GOL4G3CN

Green

GOB4-R233CN34CN

GOL4R3CN

Red

Blank

GOB4-A230CN34CN

GOL4A0CN

Amber

Blank

GOB4-B230CN34CN

GOL4B0CN

Blue

GOB4-C230CN34CN

GOL4C0CN

Clear

GOB4-F230CN34CN

GOL4F0CN

Frosted

GOB4-G230CN34CN

GOL4G0CN

Green

GOB4-R230CN34CN

GOL4R0CN

Red

Amber

1 1 0 - 1 2 0 Vo l t s
F u l l Vo l t s

Blank
Blank
Blank
Blank

••
••

Blank

1 1 0 - 1 2 0 Vo l t s

Blank
Blank

No Contact
Blocks

Blank
Blank
Blank

G I L L U M I N AT E D P U S H B U T T O N O R P U S H T O T E S T P I L O T L I G H T W I T H L E D 1 1 0 V O LT L A M P S
GOB4-A233CN34LEDCN

GOL4A3LEDCN

Amber

GOB4-G233CN34LEDCN

GOL4G3LEDCN

Green

GOB4-R233CN34LEDCN

GOL4R3LEDCN

Red

GOB4-A230CN34LEDCN

GOL4A0LEDCN

Amber

GOB4-G230CN34LEDCN

GOL4G0LEDCN

Green

GOB4-R230CN34LEDCN

GOL4R0LEDCN

Red

Blank
1 1 0 - 1 2 0 Vo l t s
F u l l Vo l t s ( L E D )

••
••

1 1 0 - 1 2 0 Vo l t s ( L E D )
No Contact Blocks

Blank
Blank
Blank
Blank
Blank

1 Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for accessories, page C30 for

complete details on Area Classification of operators, page C42 for Dimensional information.

2 Nameplates are double sided.
3 Contact Blocks are shown in their normal position.

NOTE: British standards BSEN50014 and EN50018 have special marking and relamping
demands that require modifications to the standard Killark Pilot Lights. Pilots lights
and illuminated push buttons on this page must be used for enclosures that are modified to meet ATEX/CENELEC.

C

C34

G SERIES • CONTROLS
SELECTOR SWITCHES
Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
Listed - File E12379

Selector Switch
Maintained Contact

Selector Switch
Spring Return

Certified - File LR11714
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
G S E L E C T O R S W I T C H M A I N TA I N E D C O N TA C T
EXTENDED

CONTACT ARRANGEMENT 3
Left

G025-3C3G

G05-3C3G N34

G0L53C3

••
••
Left

G05-4H8H N34

G0L54H8

Two position

Right

••
••

1

2

3

4

••
••

••
••
••

••

••

TYPE OF OPERATION 2

Right

••
G025-4H8H

Center

••
••

••

G0L52A3

••

••

G05-2A3F N34

••
••

G025-2A3F

••
••
••

CATALOG NUMBER 1
LONG

••
••

SHORT 4

Three position

Four position

••
••
G S E L E C T O R S W I T C H M A I N TA I N E D C O N TA C T W I T H O U T C O N TA C T S
G025-2A0F

G05-2A0F N34

G0L52A

None

Two position

G025-3C0G

G05-3C0G N34

G0L53C

None

Three position

G025-4H0H

G05-4H0H N34

G0L54H

None

Four position

G SELECTOR SWITCH SPRING RETURN
Left

Right

••

G0L63

••
G07-6G N34

G0L76

Left

Center

••

••

••
G034-6G

G014-6G N34

G0L146

••

••

Left

Center

Right

••

••

••
G015-6G N34

G0L156

••

Three position spring return to
center from right or left

Three position spring return to
center from right, maintain in left

••

Left

Center

••

••

••

G035-6G

Right

••

G027-6G

Two position spring return to left

••
••

G06-3F N34

••

G026-3F

••

••

Right

Three position spring return to
center from left, maintain in right

••
G S E L E C T O R S W I T C H S P R I N G R E T U R N W I T H O U T C O N TA C T S
G026-0F

G06-0F N34

G0L6

None

Two position spring return to left

G027-0G

G07-0G N34

G0L7

None

Three position spring return to
center from right or left

G034-0G

G014-0G N34

G0L14

None

Three position spring return to
center from right, maintain in left

G035-0G

G015-0G N34

G0L15

None

Three position spring return to
center from left, maintain in right

1Refer to catalog page C30 to select proper operator for enclosure, C38 & C39 for Accessories, C30 for complete details on
Area Classification of operators, C42 for Dimensional Information, C40 for Special Contact Configurations.
2Nameplates are Double sided. 2 position marked ON-OFF and Blank on other side.
3 position marked HAND-OFF-AUTO and Blank on other side. 4 position is Blank.
3Contact Blocks are shown in their normal position.
4Short style operators are suitable for Class I Group C & D, Class II Group E,F,G only.

C35

G SERIES • CONTROLS
KEYED SELECTOR SWITCHES

Class I, Div. 1 & 2, Groups B,C,D6
Class 1, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
Listed - File E12379
Certified - File LR11714

Key Operated
Selector Switch

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
G K E Y S E L E C T O R S W I T C H M A I N TA I N E D C O N TA C T 4
CATALOG NUMBER1
SHORT6

LONG

EXTENDED

G028-2A3F22D

G08-2A3F22D N34

G0L82A322D

G028-3C3G32D

G08-3C3G32D N34

G0L83C332D

CONTACT ARRANGEMENT3
Left

Left

Right

••
••

••
••
Center

••
••

TYPE OF OPERATION25
Two position

Right

••
••

••
••

Three position

G K E Y S E L E C T O R S W I T C H M A I N TA I N E D C O N TA C T W I T H O U T C O N TA C T S 4
G028-2A0F22D

G08-2A0F22D N34

G0L82A022D

None

Two position

G028-3C0G32D

G08-3C0G32D N34

G0L83C032D

None

Three position

G KEY SELECTOR SWITCH SPRING RETURN4

G037-3C6G32D N34

G0L36L322D

G0L37C632D

G0L38L632D

••

••
••

••

G0L39R632D

Two position spring return to left

Right

Three position spring return to
center from right or left

Left

Center

••

••

Right

••

••

Left

Center

••

••

••

G039-3R6G32D N34

••

Center

••
G059-3R6G32D

••
••

••

G038-3L6G32D N34

Right

Left

••
G058-3L6G32D

Left

••

G057-3C6G32D

G036-2L3F22D N34

••

G056-2L3F22D

••

••

Three position spring return to
center from right, maintain in left

Right

Three position spring return to
center from left, maintain in right

••
G K E Y S E L E C T O R S W I T C H S P R I N G R E T U R N W I T H O U T C O N TA C T S 4
G056-2L0F22D

G036-2L0F22D N34

G0L36L022D

None

Two position spring return to left

G057-3C0G32D

G037-3C0G32D N34

G0L37C032D

None

Three position spring return to
center from right or left

G058-3L0G32D

G038-3LOG32D N34

G0L38L032D

None

Three position spring return to
center from right, maintain in left

GO59-3R0G32D

G039-3R0G32D N34

G0L39R032D

None

Three position spring return to
center from left, maintain in right

1Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for Accessories, page C30 for complete
details on Area Classification of operators, page C42 for Dimensional Information, page C40 for Special Contact Configurations.
2Nameplates are Double sided. 2 position marked ON-OFF and Blank on other side. 3 position marked HAND-OFF-AUTO
and Blank on other side. 4 position is Blank.
3Contact Blocks are shown in their normal position.
4All Key Operators are furnished Keyed Different If Keyed Alike is required substitute letter “A” for letter “D” in catalog number.
5Keys are removable in Left position on 2 position selectors and in Center position on 3 position selectors. For key removal
in ALL positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
6Short style operators are suitable for Class I Group C & D, Class II Group E,F,G only.

C

C36

G SERIES • CONTROLS
S P E C I A LT Y O P E R AT O R S

Potentiometer and Rheostat
(electrical device not included)

Snap Switch

Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)

Reset

See Area Classification Chart
page C40 for Details
Certified - File LR11714

Capillary Seal

Rotary or Motor Shaft

See file for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S

G S N A P S W I T C H O P E R AT O R

CATALOG NUMBER 1
SHORT 4
LONG

G R O TA R Y O R M O T O R S H A F T O P E R AT O R
RATINGS
NAMEPLATE
125 VAC 250 VAC MARKING 2

TYPE
SWITCH

GO30-31F GO10-31F N34

• •

SPST

GO30-33F

•
• •

SPDT
(3-way)

GO10-33F N34

10 Amp
10 Amp

5 Amp

Off/On
or Blank

10 Amp

Off/On
or Blank

(UL File E10501)

CATALOG
NUMBER 1
GO-165
GO-185

SHAFT
DIAMETER
1/4”
3/8”

GO-175
GO-195

Male-Female

1/4”
3/8”

GO-50

1/2”

GO-51

1/2”

DESCRIPTION 1

TYPE

Male-Male

Rotar y or motor shaft
operator used to
transfer rotar y motion
through wall of explosion proof enclosure.

GO50 requires 1-1/4" NPSM opening (UL File E150827)
G P O T E N T I O M E T E R S A N D R H E O S TAT S O P E R AT O R

CATALOG NUMBER 1
SHORT 4
EXTENDED
LONG

TYPE

GO133

GO113 N34

GOL113

Single turn

GO134

GO114 N34

GOL114

Fifteen turn

DESCRIPTION 1
Control operator for use
with potentiometers or
rheostats having a 1/4"
diameter by 7/8" long
shaft.

(UL File E150827)

G R E S E T O P E R AT O R

CATALOG NUMBER 1
NAMEPLATE 2
SHORT 3
LONG
EXTENDED

GO40-KX2C

GO-RST

(UL File E150827)

GOLRST

Reset
or
Blank

TYPE OPERATION 1
Black plunger type reset
operator, supplied with a
6” long fiber extension
which can be removed or
cut to desired length.

G CAPILLARY SEALS
CATALOG
NUMBER 1

CAPILLARY
SIZE

GO-11388-0785

0.078±

GO-11372-0935

0.093±

.002 Dia.

.002 Dia.

TYPE
Accepts
Capillar y
With Max.
Bulb Dia.
of 9/16".

DESCRIPTION 1
Use where a mechanical
means for passing a thermostat or similar capillary tube
through the wall of a hazardous location enclosure.

1 Refer to catalog page C30 to select proper operator for enclosure, pages
C38 & C39 for Accessories, page C30 for complete details on Area
Classification of operators, page C42 for Dimensional Information.
2 Nameplates are double sided.
3 GO40 series reset button is suitable for Class II E, F, and G locations only.
4 Short style operators are suitable for Class I Group C & D, Class II Group
E,F,G only.
5 These devices are not UL or CSA approved.

C37

GCS/SWBC SERIES • CONTROLS
O P E R AT O R B O D I E S

Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
SWBC Series:
Listed - File E10514
Certified - File LR11716

Style 1 - GCS-16

Style 3 - SWBC-16

Style 2 - GCS-163

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S

GCS STYLE 1 –
CATALOG
NUMBER

W I T H D R I L L E D A N D TA P P E D O P E R AT O R H O L E S I N C O V E R 1

NO. OF
OPERATOR
HOLES

CONSISTS OF
BOX

COVER

Dimensions

DIMENSIONS
A

B

C

H

I

5/16"
(8)

5-3/16" 3-5/8"
(148)
(92)

D

E

—

G

3-1/2"
(89)

2-9/16"
(65)

4-5/16" 3-3/8"
(110)
(86)

GCS-13

1

SWB-13

X-60

6-1/8" 2-3/8"
(156)
(60)

GCS-14

1

SWB-14

X-60

6-1/8" 2-3/8"
(156)
(60)

5/16"
(8)

5-1/4"
(133)

3-5/8"
(92)

—

GCS-15

2

SWB-15

X-61

7-3/8" 3-1/8"
(187)
(79)

5/16"
(8)

6-1/2"
(165)

4"
(102)

1"
(25)

4-1/4"
(108)

3-1/4"
(82)

GCS-16

3

SWB-16

X-62

5/16"
(8)

8-1/2"
(216)

4"
(108)

2"
(51)

4-1/4"
(105)

3-1/4"
(82)

GCS-83

4

SWB-83 2

9-3/8" 3-3/16"
(238)
(81)

X-84

3-1/4"
(82)

3/8"
(10)

11-7/8"
(302)

4-3/8" 1-1/4" 4-3/16" 3-1/4"
(111)
(32)
(106)
(82)

GCS-85

5

SWB-83 2

13"
(330)

X-85

13"
(330)

3-1/4"
(82)

3/8"
(10)

11-7/8"
(302)

4-3/8" 2"
(111)
(51)

GCS STYLE 2 –

4-3/16" 3-3/16"
(106)
(81)

W I T H D R I L L E D A N D TA P P E D O P E R AT O R H O L E S I N B A C K O F B O X 1

GCS-131

1

SWB-13

X-10

6-1/8" 2-3/8"
(156)
(60)

5/16"
(8)

5-3/16" 3-5/8"
(148)
(92)

—

3-1/2"
(89)

GCS-141

1

SWB-14

X-10

6-1/8" 2-3/8"
(156)
(60)

5/16"
(8)

5-1/4"
(133)

3-5/8"
(92)

—

4-5/16" 3-3/8"
(110)
(86)

X-11

7-3/8" 3-1/8"
(187)
(79)

5/16"
(8)

6-1/2"
(165)

4"
(102)

1"
(25)

4-1/4"
(108)

3-1/4"
(82)

9-3/8" 3-3/16"
(238)
(81)

5/16"
(8)

8-1/2"
(216)

4"
(102)

2"
(51)

4-1/4"
(108)

3-1/4"
(82)

GCS-152

2

SWB-15

2-9/16"
(65)

GCS-163

3

SWB-16

X-12

GCS-834

4

SWB-83 2

X-83

3-1/4"
(82)

3/8"
(10)

11-7/8"
(302)

4-3/8" 1-1/4" 4-3/16" 3-1/4"
(111)
(32)
(106)
(82)

GCS-835

5

SWB-83 2

13"
(330)

X-83

13"
(330)

3-1/4"
(82)

3/8"
(10)

11-7/8"
(302)

4-3/8" 2"
(111)
(51)

SWB STYLE 3 –

4-3/16" 3-3/16"
(106)
(81)

B L A N K B O X A N D C O V E R - N O O P E R AT O R H O L E S 1

SWBC-13

None

SWB-13

X-10

6-1/8" 2-3/8"
(156)
(60)

5/16"
(8)

5-3/16" 3-5/8"
(148)
(92)

—

3-1/2"
(89)

SWBC-14

None

SWB-14

X-10

6-1/8" 2-3/8"
(156)
(60)

5/16"
(8)

5-1/4"
(133)

3-5/8"
(92)

—

4-5/16" 3-3/8"
(110)
(86)

SWBC-15

None

SWB-15

X-11

7-3/8" 3-1/8"
(187)
(79)

5/16"
(8)

6-1/2"
(165)

4"
(102)

—

4-1/4"
(108)

3-1/4"
(82)

SWBC-16

None

SWB-16

X-12

5/16"
(8)

8-1/2"
(216)

4"
(111)

—

4-1/4"
(108)

3-1/4"
(82)

SWBC-83

None

SWB-83 2

9-3/8" 3-3/16"
(238)
(81)

X-83

3/8"
(10)

11-7/8"
(302)

4-3/8"
(111)

—

4-3/16" 3-3/16"
(106)
(81)

13"
(330)

3-1/4"
(82)

2-9/16"
(65)

1 All GCS and SWBC Series are cataloged without conduit openings.
Specify conduit size and location when ordering.
2 GCS-83, GCS-834, and GCS-85, GCS-835 are provided with four
mounting lugs.

Notes: Use short style operators for cover
devices and long style operators for
back of box mounted devices when
panel mounting.
Style 2 control stations with holes in
back of box are typically used for panel
mounting.

C

C38

Rubber
Boot

G SERIES • CONTROLS
A C C E S S O R I E S / R E P L A C E M E N T PA R T S

Trim Locknut
Spacer

Hole
Plug

Transformer
GO-8670

Push Button Lockout
GO-8665
Push Button Lockout
GO-10502

ACCESSORIES
CATALOG NUMBER

USED ON OPERATOR TYPE

DESCRIPTION

GO-8176-1

GO1, GO21, GOL1

Protective rubber boot (Black)

GO-8176-2

GO1, GO21, GOL1

Protective rubber boot (Red)

GO-8176-3

GO1, GO21, GOL1

Protective rubber boot (Green)

GO-8177

3/4” NPSM

Hole plug

GO-8222

1/4” Thick, Used as external spacer.

Trim locknut spacer

GO-8670-32

GO23, GOB3, GOL3

Transformer 220V-110V

GO-8670-34

GO23, GOB3, GOL3

Transformer 440V-110V

GO-8671-42

GOB4, GOL4

Transformer 220V-110V

GO-8671-44

GOB4, GOL4

Transformer 440V-110V

GO-8665

GO2, GO22, GOL2, GOR11

Push button lockout

GO-10502

GO1, GO21, GOL1

Push button lockout

GO567-LOK

GO & GOL5-6-7-14-15-26-27-34-35

Selector switch lockout

GO-RL

For use with GO’s

Sealing lockout

GO-9824

GO40, GO-RST, GOLRST

Reset plate

B7PLR220

GO23, GOB3, GOL3, GOB4, GOL4

Resistor kit 220V-110V

B7PLR440

GO23, GOB3, GOL3, GOB4. GOL4

Resistor kit 440V-110V

B7PLR550

GO23, GOB3, GOL3, GOB4, GOL4

Resistor kit 550V-110V

GOLED-R110

GOB3, GOL3, GOB4, GOL4

LED lamps 120V (Red)

GOLED-G110

GOB3, GOL3, GOB4, GOL4

LED lamps 120V (Green)

GOLED-A110

GOB3, GOL3, GOB4, GOL4

LED lamps 120V (Amber)

Selector Switch Lockout

Reset Plate

Sealing Locknut
GO-RL

Lens Guard
Assembly
REPLACEMENT LENS GUARD ASSEMBLIES
CATALOG NUMBER
GOL3/GOB3/GO23 SERIES
GOL4/GOB4 SERIES

R E P L A C E M E N T B L A N K N A M E P L AT E S
LENS COLOR

GO15726-A

K I T- 3 5 4

Amber

GO15726-B

K I T- 3 5 5

Blue

GO15726-C

K I T- 3 5 6

Clear

GO15726-F

K I T- 3 5 7

Frosted

GO15726-G

K I T- 3 5 8

Green

GO15726-R

K I T- 3 5 9

Red

CATALOG NUMBER

DESCRIPTION

YOKK-9484-2

Push button pilot lights

YOKK-10291

Double push button

YOKK-10286

2 Position selector switch

YOKK-10287

3 Position selector switch

YOKK-10285

4 Position selector switch

C39
C49

G SERIES • CONTROLS
A C C E S S O R I E S / R E P L A C E M E N T PA R T S

GOMLOCK

Standard Mushroom
Momentary

Jumbo Mushroom
Momentary

ACCESSORIES
CATALOG NUMBER

FOR USE ON OPERATOR TYPE

DESCRIPTION

GOMLOCK

GOM1-GOM21-GOML-GO1-GO21-GOL1

Lock Out for Standard Size Momentar y & Maintained Head

GOMSTG

GO1-GO21-GOL1

Standard Size Momentar y Mushroom Head (Green)

GOMSTR

GO1-GO21-GOL1

Standard Size Momentar y Mushroom Head (Red)

GOMSTK

GO1-GO21-GOL1

Standard Size Momentar y Mushroom Head (Black)

GOMJUR

GO1-GO21-GOL1

Jumbo Size Momentar y Mushroom Head (Red)

Dimensions - Standard Mushroom - 1-1/2” Diameter
Jumbo Mushroom - 2-1/4” Diameter

Replacement
Parts

Bayonet Base
GOL3/GOL4
GOB3/GOB4

Slide Base
GO23

Contact Block
G O S TA N D A R D C O N TA C T B L O C K S

PILOT LIGHT LAMPS
CATALOG
NUMBER
GO-8668-120

VOLTS
120

GO-8668-24

24

YOSY120MB

120

YOSY24MB

WATTS
3

24

AMPS
0.025

STYLE
GO23

1.7

0.073

3

0.025

GOB3/GOL3

1.7

0.073

GOB4/GOL4

LED Lamp for G0B3/G0L3 - G0B4/G0L4

PILOT LIGHT LED LAMPS
CATALOG NUMBER

VOLTS

COLOR

GOLED-A110

110 VAC/DC

Amber

GOLED-B110

110 VAC/DC

Blue

GOLED-G110

110 VAC/DC

Green

GOLED-R110

110 VAC/DC

Red

GOLED-W110

110 VAC/DC

White

GOLED-A24

24 VAC/DC

Amber

GOLED-B24

24 VAC/DC

Blue

GOLED-G24

24 VAC/DC

Green

GOLED-R24

24 VAC/DC

Red

GOLED-W24

24 VAC/DC

White

CATALOG NUMBER

DESCRIPTION

GO-8672-BJK

1 N.O.

GO-8672-BJJ

1 N.C.

GO-8672-BJH

1 N.O. Early make

GO-8672-BJE

1 N.C. Late break

C

C40

G SERIES • CONTROLS
C U S T O M O P E R AT O R O R D E R I N G S Y S T E M

Example:

GO1
—
FORM
SINGLE PUSH BUTTON
LONG STYLE

RX
COLOR
(RED)

2
CONTACTS
(1 N.C.)

B
NAMEPLATE
(STOP)

N34
CONSTANT

NOTE: For faster delivery on custom operators order push buttons and selector
switches without contact blocks and order contacts as a separate item.

F E AT U R E S - S P E C I F I C AT I O N S
1. Select operator form and style
(short, long or extended).
2. Using the catalog numbering system
below, insert the proper letter or
number symbol as shown in appropriate charts on page C41, write the
complete catalog number.

CATALOG SERIES

COLOR

VOLTAGE

POSITION

3. Spaces in catalog numbering system which have symbol already
filled in cannot be changed.
4. Order accessories as separate
item from pages C38 & C39.

CAM

CONTACTS

NAMEPLATE

KEY LOCK

5. Add “N34” suffix to the end of all
long style operators with the following prefix; G01, G02, G0B3, G0B4,
G05, G06, G07, G08, G010, G011,
G014, G015, G036, G037, G038,
G039.

KEY TYPE

DESCRIPTION

GO1 & GO21
GOL1

Chart 1

Chart 4

Chart 8

Single push button:
(Momentar y contact)

GOM1

Chart 1

Chart 4

Chart 8

Single push button:
(Maintained contact)

GO2 & GO22
GOL2

Chart 2

Chart 4

Chart 8

Double push button:
(Momentar y contact)

GOR11

Chart 2

Chart 4

Chart 8

Double push button:
(Maintained contact)

GOB3 & GO23
GOL3

Chart 3

Chart 6

Chart 8

Pilot light

GOB4
GOL4

Chart 3

Chart 6

Chart 4

Chart 8

Illuminated push button

Chart 4

Chart 8

Selector switch
(Maintained contact)

GO6 & GO26
GOL6

Chart 4

Chart 8

Selector switch
(2 Position, spring return to left)

GO7 & GO27
GOL7

Chart 4

Chart 8

Selector switch
(3 Position, return to center from center)

GO14 & GO34
GOL14

Chart 4

Chart 8

Selector switch
(3 Position, return to center from right)

GO15 & GO35
GOL15

Chart 4

Chart 8

Selector switch
(3 Position, return to center from left)

Chart 4

Chart 8

Chart 9

Chart 10

Key selector switch
(Maintained contact)

GO36 & GO56
GOL36

Chart 4

Chart 8

Chart 9

Chart 10

Key selector switch
(2 Position, spring return to left)

GO37 & GO57
GOL37

Chart 4

Chart 8

Chart 9

Chart 10

Key selector switch
(3 Position, spring return to center)

GO38 & GO58
GOL38

Chart 4

Chart 8

Chart 9

Chart 10

Key selector switch
(3 Position, return to center from right)

GO39 & GO59
GOL39

Chart 4

Chart 8

Chart 9

Chart 10

Key selector switch
(3 Position, return to center from left)

GO5 & GO25
GOL5

GO8 & GO28
GOL8

Chart 5

Chart 5

Chart 7

Chart 7

C41

H A Z A R D O U S A N D H O S T I L E L O C AT I O N S
G S Y M B O L S F O R O R D E R I N G C U S T O M O P E R AT O R S
CHART 7A – SELECTOR SWITCH CAMS

CHART 1 – SINGLE BUTTON
GOL1
GOM1
GO1
GO21
SYMBOL SYMBOL SYMBOL SYMBOL

COLOR

KX

KZ

K

KM

Black

RX

RZ

R

RM

Red

GX

GZ

G

GM

Green

CAM AND CONTACT SELECTION TABLE FOR 2 AND 3 POSITION SELECTOR OPERATOR
Left
position

Center
position

Right
position

CHART 2 – DOUBLE BUTTON
SYMBOL

COLOR

KK

Black/Black

GG

Green/Green

RR

Red/Red

RG

Red/Green

KR

SYMBOL

CONTACTS BLOCKS

A

Black/Red

KG

Black/Green

B
C

CHART 3 – PILOT LIGHT LENS
SYMBOL

COLOR

A

Amber

B

Blue

C

Clear

F

Frosted

G

Green

R

Red

E
G

1

One N.O. block

2

One N.C. block

3

One universal
(One N.O. and one N.C.)

4

One delayed break
N.C. block

5

One early make N.O.
block

6

Two N.O. blocks

7

Two N.C. blocks

8

Two universal
(Two N.O. and two N.C.)

0

Omit contact block

CHART 5 – SELECTOR SWITCHES
NO. OF POSITIONS

2

Two

3

Three

CAM

LEFT
RIGHT
BLOCKS BLOCKS

X

X

O

NO

O

O

X

X

NC

X

O

X

NO

O

NC

X

O

X

X

O

X

O

O

X

O

X

O

O

O

O

NO

O

O

O

O

X

X

NC

O

O

X

X

O

O

NO

O

O

O

O

X

X

NC

O

O

X

X

O

O

NO

X

X

O

O

O

O

NC

X

O

O

X

O

O

NO

O

O

O

O

X

X

PART NUMBER

A

0106775B

B

11586ABAB

C

11587ABAB

D

11588ABAB

E

11589ABAB

G

11590ABAB

NAMEPLATE MARKINGS
FRONT

SYMBOL

G SERIES FORMS THAT
NAMEPLATE CAN BE USED ON

BACK

A

Omit nameplate

Omit nameplate

B

Start

Stop

GO1, 21, 23, 20, 40, GOB3

C

Blank

Reset

GO1, 21, 23, 20, 40, GOB3, GOB4

All

E

Blank

On

GOR4

F

Blank-Blank

Off-On

GO5, 25, 6, 26, 8, 28, 10, 30, 36, 56

G

Blank-Blank-Blank

Hand-Off-Auto

GO5, 25, 7, 27, 8, 28, 10, 30, 14, 34

H

Blank-Blank-Blank-Blank

Start-Stop

GO5, 25, 10, 30

CHART 10 - KEY STYLE
TYPE

22

2 Position key remove left

20

2 Position key remove both

23

23

120

32

3 Position key remove center

4

4

24

30

3 Position key remove all

VOLTAGE

C

C H A R T 8 – N A M E P L AT E S 1

SYMBOL

CHART 6 – PILOT LIGHT LAMPS
GOB3/GOB4
SYMBOL

RIGHT
BLOCKS

NC

CHART 9 – KEY LOCK

GO23
SYMBOL

LEFT
BLOCKS

CHART 7B

ARRANGEMENT

SYMBOL

RIGHT
BLOCKS

Note: Spring return operators are supplied with special fixed cam. Changes cannot be made for cam
substitution.

C H A R T 4 – C O N TA C T B L O C K S
SYMBOL

D

LEFT
BLOCKS

SYMBOL

TYPE

D

Keys different

A

Keys alike

1 Symbol not required on extended length GOL
part number.

C42

G SERIES • CONTROLS
DIMENSIONS
Push Buttons

G DIMENSIONS
SERIES

FIGURE

A

D

C

B

GO1

1

15/16"(24)

1-3/4"(44)

3-7/16"(87)

1-1/4"(32)

GO2

3

13/16"(21)

2"(51)

3-3/4"(95)

—

GOB3

4

1-1/8"(29)

2"(51)

2-3/4"(70)

1-9/16"(40)

GOB4

5

2-3/8"(60)

2-1/4"(57)

4"(101)

1-13/16"(46)

GO5

9

1-5/16"(33)

1-3/4"(44)

3-7/16"(87)

1-1/4"(32)

GO6,GO7,GO14,GO15

9

1-5/16"(33)

1-3/4"(44)

3-13/16"(97)

1-1/4"(32)

GO8

10

2-9/16"(65)

1-3/4"(44)

3-1/2"(89)

1-1/4"(32)

GO10

11

1-5/16"(33)

1-3/4"(44)

4"(101)

1-1/4"(32)

GO16,GO18

7

1-1/4"(32)

1"(25)

13/16"(21)

1-1/2"(38)

GO17,GO19

7

13/16"(21)

1"(25)

13/16"(21)

1-1/2"(38)

GO21

1

15/16"(24)

3/4"(19)

2-7/16"(62)

1-1/4"(32)

GO22

3

13/16"(21)

1"(25)

2-3/4"(70)

—

GO23

4

1-1/8"(29)

1"(25)

1-3/4"(44)

1-9/16"(40)

GO25

9

1-5/16"(33)

3/4"(19)

2-7/16"(62)

1-1/4"(32)

GO26,GO27,GO34,GO35

9

1-5/16"(33)

3/4"(19)

2-13/16"(71)

1-1/4"(32)

GO30

11

1-5/16"(33)

3/4"(19)

3"(76)

1-1/4"(32)

GO36,GO37,GO38,GO39

10

2-9/16"(65)

1-3/4"(00)

3-7/8"(98)

1-1/4"(32)

GO40

2

15/16"(24)

11/16"(17)

1"(25)

1-1/4"(32)

GO50

7

1-1/2"(38)

2"(51)

6-5/16"(160)

2-5/16"(59)

GO51

7

2-1/4"(57)

1-5/8"(41)

5-9/16"(141)

1"(25)

GO56,GO57,GO58,GO59

10

2-9/16"(65)

3/4"(19)

2-7/8"(73)

1-1/4"(32)

GO113,GO114

6

1"(25)

2"(51)

3-5/8"(67)

1-13/16"(46)

GO133,GO134

6

1"(25)

1"(25)

2-5/8"(67)

1-13/16"(46)

GO-11388-078

8

1-5/16"(33)

3/4"(19)

N/A

1-1/2"(38)

GO-11372-093

8

1-5/16"(33)

3/4"(19)

N/A

1-1/2"(38)

GOR11

3

13/16"(21)

2"(51)

4-1/8"(105)

—

GO-RST

2

15/16"(24)

2-5/16"(59)

2-3/8"(+6")(60)

1-1/4"(32)

GOM1

1

1-7/8"(48)

1-7/16"(37)

4"(101)

1-5/8"(41)

GOL1

1

15/16"(24)

2-3/4"(70)

4-7/16"(113)

1-1/4"(32)

GOL2

3

13/16"(210)

2-3/4"(70)

4-1/2"(114)

—

GOL3

4

1-1/8"(29)

2-3/4"(70)

3-3/8"(86)

1-9/16"(40)

GOL4

5

2-3/8"(60)

2-3/4"(70)

4-5/8"(117)

1-13/16"(46)

GOL5

9

1-5/16"(33)

2-3/4"(70)

4-7/16"(113)

1-1/4"(32)

GOL6,GOL7,GOL14,GOL15

9

1-5/16"(33)

2-3/4"(70)

4-13/16"(122)

1-1/4"(32)

GOL8

10

2-9/16"(65)

2-3/4"(70)

4-1/2"(114)

1-1/4"(32)

GOL36,GOL37,GOL38,GOL

10

2-9/16"(65)

2-3/4"(70)

4-7/8"(124)

1-1/4"(32)

GOL113,GOL114

6

1"(25)

3"(76)

4-5/8"(117)

1-13/16"(46)

GOLRST

2

15/16"(24)

2-3/4"(70)

3"(+6")(76)

1-1/4"(32)

FIGURE 1

FIGURE 2

FIGURE 3

Pilot Lights

EXTENDED LENGTH OPERATORS:

NOTE: All operators are for installation into a 3/4"-14 NPSM opening except GO50 which is for
1-1/4"-11-1/2 NPSM and GO-11388-078 + GO-11372-093 which are for use in a 3/4"-14 NPT opening.

FIGURE 4

FIGURE 5

Special Operators

FIGURE 6

FIGURE 7

FIGURE 8

Selector Switches

FIGURE 9

FIGURE 10

FIGURE 11

C43

B7 SERIES • CONTROLS
M A G N E T I C M O T O R S TA R T E R S

Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
Classified - File E83969
Certified - File LR11714

Line Starter

Combination Starter

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S

Applications
The PRISM® B7 Series of across-theline starter and combination motor control centers utilize SSNR single-speed,
non-reversing NEMA type starters.
Prism enclosures universal design
accommodates, as standard, the magnetic starters made by the following
manufacturers:
• Allen-Bradley — 509 Series
• Cutler-Hammer — A10 Series
• Cutler-Hammer — AN16 Series
• Furnas — Class 14 Series
• GE — CR306 Series
• Square D — 8536 Series
• Telemecanique — A20 Series
• Westinghouse — A200 Series
In addition, the SSNR combination
starters will house a motor circuit
protector or circuit breakers manufactured by:
• Square D — FA, FH, FC Frames
• Cutler-Hammer –– HMC, EHD, FDB,
FD, HFD, FDC Frames
• General Electric –– TEB-TEC-TEDTHED-Frame
There is sufficient space in the combination starter enclosure for a control
transformer, if required.

Standard Materials
Enclosure – Copper-free aluminum
O-ring Gasket – BUNA-N nitrile
Cover Bolts – 316 grade stainless steel
CB/MCP Handle – Copper-free
aluminum
Reset Operator – Thermoplastic
polyester button molded onto stainless
steel shaft. Aluminum shroud.
Mounting Pan – Sheet aluminum
Hinge – Aluminum with stainless
steel pin
Reset Shroud – Black anodized
Features
• Nema 4, 4X rated – providing protection from hose directed water and
corrosion
• Universal mounting pan, pre-drilled
to facilitate easy field installation of
starters. Provision for grounding
supplied as standard.
• More wiring room – meets latest NEC
wire bend requirements
• Quick release, captivated cover bolts
of 316 grade stainless steel
• Flange sealing gasket located to the
inside of cover bolt – preventing
water seepage into enclosure through
bolt holes
• Hinged cover provided as standard
for an extra measure of safety and
convenience
• Breaker (MCP) handle can be padlocked in “ON” or “OFF” position

• Provisions provided for drain and
breather plus conduit openings for
power and control
• Reset button provided as standard
• Two control operator openings provided plugged as standard. Additional
openings can be factory or field
drilled.
• Copper-free (less than 4/10 of 1%
copper) enclosure
• Ductile mounting lugs
Catalog Logic
See page C48 for enclosures
with controls.

C

C44

B7 SERIES • CONTROLS
M A G N E T I C M O T O R S TA R T E R S

Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
Classified - File E83969
Certified - File LR11714

Line Starter

Combination Starter

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Magnetic Line Starters - 3 Pole,
3 Phase, Single Speed Non Reversing 600 VAC Max, 60Hz
Square D or Cutler-Hammer motor
starters available as standard.
Heaters not included. See page
C49 to order.

B 7 M A G N E T I C L I N E S TA R T E R S
NEMA
STARTER
SIZE

MOTOR
VOLTS

CATALOG NUMBER
COIL
MAX. HP CUTLER-HAMMER
SQUARE D
VOLTS 1
SERIES AN16
SERIES 8536
B7010SB
B7010HB
—
120

0

SEP. CONTROL

0

230

240

3

B7010HG

B7010SG

0

460

480

5

B7010HK

B7010SK

0

575

600

5

B7010HM

B7010SM

1

SEP. CONTROL

120

—

B7011HB

B7011SB

1

230

240

7-1/2

B7011HG

B7011SG

1

460

480

10

B7011HK

B7011SK

1

575

600

10

B7011HM

B7011SM

2

SEP. CONTROL

120

—

B7012HB

B7012SB

2

230

240

15

B7012HG

B7012SG

2

460

480

25

B7012HK

B7012SK

2

575

600

25

B7012HM

B7012SM

3

SEP. CONTROL

120

—

B7013HB

B7013SB

3

230

240

30

B7013HG

B7013SG

3

460

480

50

B7013HK

B7013SK

3

575

600

50

B7013HM

B7013SM

4

SEP. CONTROL

120

—

B7014HB

B7014SB

4

230

240

50

B7014HG

B7014SG

4

460

480

100

B7014HK

B7014SK

4

575

600

100

B7014HM

B7014SM

1 See catalog logic page C48 for other standard coil voltages.

ENCLOSURE ONLY
NO INTERIORS

B7011

B7011

B7012

B7013

B7014

2 Control transformers for use on Combination Starters Only. Will not fit into B701 Series of Non-

Combination Starters.

3 See catalog page C48 for modifications and accessories to enclosure.

C45

B7 SERIES • CONTROLS
M A G N E T I C M O T O R S TA R T E R S
Combination Starters
3-Pole, 3-Phase, Single
Speed Non Reversing
600 VAC Max, 60Hz
Square D or CutlerHammer motor
starters and motor circuit protector available. Heaters not
included. See page
C49 to order.
Enclosure sized to
accommodate control
circuit transformer.

B 7 C O M B I N AT I O N M A G N E T I C L I N E S TA R T E R S
NEMA
MOTOR
STARTER
VOLTS
SIZE
SEP. CONTROL
0

COIL
MAX. HP
VOLTS 1

DISCONNECT
TRIP
AMPS
3

CATALOG
CUTLER-HAMMER
SERIES AN16
B7020HBCA

NUMBER
SQUARE D
SERIES 8536
B7020SBAA

120

—

0

SEP, CONTROL

120

—

7

B7020HBCB

B7020SBAB

0

SEP, CONTROL

120

—

15

B7020HBCC

B7020SBAC

0

230

240

1

7

B7020HGCB

B7020SGAB

0

230

240

3

15

B7020HGCC

B7020SGAC

0

460

480

1

3

B7020HKCA

B7020SKAA

0

460

480

2

7

B7020HKCB

B7020SKAB

0

460

480

5

15

B7020HKCC

B7020SKAC

0

575

600

1

3

B7020HMCA

B7020SMAA

0

575

600

2

7

B7020HMCB

B7020SMAB

0

575

600

5

15

B7020HMCC

B7020SMAC

1

SEP, CONTROL

120

—

15

B7021HBCC

B7021SBAC

1

SEP. CONTROL

120

—

30

B7021HBCF

B7021SBAF

1

230

240

7-1/2

30

B7021HGCF

B7021SGAF

1

460

480

10

30

B7021HKCF

B7021SKAF

1

575

600

10

30

B7021HMCF

B7021SMAF

2

SEP. CONTROL

120

—

50

B7022HBCK

B7022SBAK

2

SEP, CONTROL

120

—

70

B7022HBCM

B7022SBAM

2

230

240

15

50

B7022HGCK

B7022SGAK

2

230

240

15

70

B7022HGCM

B7022SGAM

2

460

480

25

50

B7022HKCK

B7022SKAK

2

575

600

25

50

B7022HMCK

B7022SMAK

3

SEP, CONTROL

120

—

100

B7023HBCQ

B7023SBAQ

3

230

240

30

100

B7023HGCQ

B7023SGAQ

3

460

480

50

100

3

575

600

50

100

B7023HKCQ
B7023HMCQ

B7023SKAQ
B7023SMAQ

4

SEP, CONTROL

120

—

150

B7024HBCT

B7024SBBT

4

230

240

50

150

B7024HGCT

B7024SGBT

4

460

480

100

150

B7024HKCT

B7024SKBT

4

575

600

100

150

B7024HMCT

B7024SMBT
B7025SBSMAGK250

5

SEP, CONTROL

120

—

250

B7025CBCMCPJ250

5

SEP, CONTROL

120

—

400

B7025CBCMCPK400

B7025SBSMAGL400

5

230

240

75

250

B7025CGCMCPJ250

B7025SGSMAGK250

5

230

240

100

400

B7025CGCMCPK400 B7025SGSMAGL400

5

460

480

150

250

B7025CKCMCPJ250

B7025SKSMAGK250

5

460

480

200

400

B7025CKCMCPK400

B7025SKSMAGL400

5

575

600

150

250

B7025CMCMCPJ250 B7025SMSMAGK250

5

575

600

200

400

B7025CMCMCPK400 B7025SMSMAGL400

ENCLOSURE ONLY
NO INTERIORS

B7021

B7021

B7022

B7023

B7024

See chart
below

1 See catalog logic page C48 for other standard coil voltages.

2 Combination Starter enclosures provide sufficient space for factory of field mounting a control transformer.
3 See catalog page C48 for modifications and accessories to enclosure.

S I Z E 5 C O M B I N AT I O N M O T O R S TA R T E R E N C L O S U R E O N LY
STARTER
MANUFACTURER

STARTER
TYPE

C-H

CIRCUIT BREAKER FRAME
GE
SQ-D

ENCLOSURE
CAT. NUMBER

Allen Bradley

Series 509

J

F-225

K

B7025A2

Allen Bradley

Series 509

K

J-600

L

B7025A4

Cutler Hammer

Freedom-AN16

J

F-225

K

B7025C2

Cutler Hammer

Freedom-AN16

K

J-600

L

B7025C4

General Electric

Series 306

J

F-225

K

B7025G2

General Electric

Series 306

K

J-600

L

B7025G4

Square D

Series 8536

J

F-225

K

B7025S2

Square D

Series 8536

K

J-600

L

B7025S4

Westinghouse

Advantage

J

F-225

K

B7025W2

Westinghouse

Advantage

K

J-600

L

B7025W4

C

C46

B7 SERIES • CONTROLS
C O M B I N AT I O N S TA R T E R S

Supplied with Cutler-Hammer
Advantage Starters
Applications
The PRISM® B7 Series of Combination
Starters are used for Motor Control and
Circuit protection of motors in
Hazardous And Hostile locations.
These Hazardous locations are typically
due to the presence of flammable
gases or vapors, combustible dust, or
easily ignitable fibers and flyings, and
areas which are subject to corrosion,
weather and dampness.
Advantage Starter Features
• Solid-State Electronic Starter
• Brownout Protection
• Communications capabilities
• Overload Heaters not required
• Phase loss and phase unbalance
protection
• Selectable automatic/manual reset
• Class ll ground-fault protection
Enclosure Features
• Nema 4, 4X rated – providing protection from hose directed water and
corrosion
• Universal mounting pan, pre-drilled to
facilitate easy field installation of
starters. Provision for grounding supplied as standard.
• More wiring room – meets latest NEC
wire bend requirements
• Quick release, captivated cover bolts
of 316 grade stainless steel

• Flange sealing gasket located to the
inside of cover bolt – preventing
water seepage into enclosure
through bolt holes
• Hinged cover provided as standard
for an extra measure of safety and
convenience
• Breaker (MCP) handle can be padlocked in “ON” or “OFF” position
• Provisions provided for drain and
breather plus conduit openings for
power and control
• Field replaceable reset button provided as standard with gold contact
blocks
• Two control operator openings
provided plugged as standard.
Additional openings can be factory
or field drilled
• Copper-free (less than 4/10 of 1%
copper) enclosure
• Ductile mounting lugs
Modifications & Accessories
• Select from B7 Modification Chart on
page C48
• Minimum Control Transformer
• Size 1-2 100VA
• Size 3-4 150VA
• Size 5 300VA
• Advantage Starters Auxiliary Contact
Modules

Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
Classified - File E83969
Certified - File LR11714
See files for details or call Killark.

Standard Materials
Enclosure – Copper-free aluminum
O-ring Gasket – BUNA-N nitrile
Cover Bolts – 316 grade stainless steel
CB/MCP Handle – Copper-free
aluminum
Reset Operator – Thermoplastic polyester button molded onto stainless steel
shaft. Aluminum shroud.
Mounting Pan – Sheet aluminum
Hinge – Aluminum with stainless steel
pin
Reset Shroud – Black anodized

• 2NO/2NC = B7ADAC

B 7 A D C O M B I N AT I O N S TA R T E R
NEMA STARTER
SIZE
1L

MOTOR
VOLTS
230

1

460

2

575

2

230
1

2

3

4

5

MAXIMUM
HP

COIL
VOLTS

FULL LOAD
AMPERAGE RANGE(1)

DISCONNECT
AMP TRIP
3

120/60

.47-4.14

CATALOG NUMBER
WITH MOTOR PROTECTOR AND STARTER ENCLOSURE ONLY
B7AD02LH6CA

7

B7AD02LH6CB

15

B7AD02LH6CC

B7AD021

7-1/2

460

10

575

10

230

15

460

25

575

25

230

30

460

50

575

50

230

50

460

100

575

100

230

100

460

200

575

200

120/60

3.15-27

30

B7AD021H6CF

B7ADO21

120/60

3.15-45

50

B7AD022H6CK

B7AD022

120/60

9.9-90

100

B7AD023H6CQ

B7AD023

120/60

9.9-133

150

B7AD024H6CT

B7AD024

120/60

38.3-270

400

B7AD025H6K400

B7AD025K

Notes: (1) Heaters are not required with the Advantage Starter. The Overload Module has trip current settings via DIP Switch
between the amperage range shown.
(2) All Advantage Starters are wired for separate control and must be controlled at the coil voltage shown. For 50 HZ applications a 110V 50 Hz coil is available. To order with this 50 Hz coil replace the number “6” in catalog number with “5”.
(3) Enclosures provide sufficient space for factory or field mounting a control transformer.

C47

B7 SERIES • CONTROLS
M O T O R S TA R T E R S D I M E N S I O N S
B7 DIMENSIONS
CATALOG
NUMBER

NEMA
SIZE

DIMENSIONS

TYPE
A

B

C

D

9-1/8"

3-5/8"

(280)

(232)

(92)

(416)

(54)

12-1/2"

9-1/8"

5"

18-3/8"

2-1/2"

(317)

(232)

(127)

(467)

(63)

(63)

26-1/4"

12-1/2"

10-3/4"

5"

24-5/8"

2-1/2"

2-3/4"

4-1/16"

5-1/2"

(667)

(317)

(276)

(127)

(625)

(63)

(70)

(103)

(140)

Starter Only

34-1/4"

16-1/2"

11-1/2"

9"

32-5/8"

3-3/4"

4"

4-7/16"

6"

(870)

(419)

(292)

(229)

(830)

(95)

(102)

(113)

(152)

Combination
Starter

23"

14-1/2"

9-1/8"

7"

21-3/8"

2-1/8"

2-1/2"

2-11/16"

3-7/16"

(584)

(368)

(232)

(178)

(543)

(54)

(64)

(68)

(87)

B7011

0,1

Starter Only

18"
(457)

B7012

2

Starter Only

20"
(508)

Starter Only

B7013
B7014
B7021
B7022
B7023
B7024

3
4
0,1
2
3
4

11"

E
16-3/8"

F

G

2-1/8"

H

2-3/8"

I

2-11/16"

3-7/16"

(60)

(68)

(87)

2-1/2"

2-11/16"

3-3/16"

(68)

(81)

25-1/2"

14-1/2"

9-1/8"

7"

23-7¼8"

2-1/8"

2-1/2"

2-11/16"

3-7/16"

(648)

(368)

(232)

(178)

(606)

(54)

(64)

(68)

(87)

Combination
Starter

27-1/4"

17-7/8"

11"

10-3/8"

25-5/8"

3-1/2"

(692)

(454)

(280)

(263)

(651)

(89)

Combination
Starter

34-1/4"

21-1/2"

11-7/8"

14"

32-5/8"

4-3/4"

5"

4-9/16"

(870)

(546)

(302)

(356)

(829)

(121)

(127)

(116)

Combination
Starter

3-1/2"
(89)

4-3/16"
(106)

5-1/2"

EST.
CONDUIT OPENINGS
ENCLOLSRE
TOP/BOTTOM (IN.)1
WEIGH
DRAIN
POWER CONTROL
LBS.
BREATHER
46
1-1/2"
3/4"
1/2"
56

1-1/2"

3/4"

1/2"

80

2"

1"

1/2"

155

3"

1"

1/2"

78

1-1/2"

3/4"

1/2"

88

1-1/2"

3/4"

1/2"

143

2"

1"

1/2"

235

3"

1"

1/2"

(140)

6-3/16"
(157)

1 1/2" conduit openings may be used for drain and/or breather installation. Smaller conduit openings may be used by utilizing reducing bushings.

Custom conduit sizes and locations are available upon request.

D I M E N S I O N S F O R S I Z E 5 C O M B I N AT I O N S TA R T E R
A
62-1/4"
(1581)

B
20-1/4"
(514)

C
15"
(381)

Dimensions B7 Size 0 Thru 4

D
18-1/2"
(470)

DIMENSIONS
E
F
43-1/2"
(1105)

2-5/8"
(67)

G

H

I

3-1/8"
(79)

5-3/8"
(137)

7-3/8"
(187)

J
3-1/2
(89)

CONDUIT TOP & BTM. (NPT)
K
L
M
4"
(102)

1/2"
(13)

1"
(25)

ENCL. WT.
(LBS.)
540

Dimensions B7 Size 5

C

C48

B7 SERIES • CONTROLS
M O T O R S TA R T E R S A C C E S S O R I E S / C ATA L O G L O G I C
B 7 M O D I F I C AT I O N S A N D A C C E S S O R I E S ( C O N T I N U E D )

B 7 M O D I F I C AT I O N S A N D A C C E S S O R I E S
CATALOG NUMBER
SIZE 0 THRU 4 SIZE 5

DESCRIPTION

CATALOG NUMBER
SIZE 0 THRU 4
SIZE 5

DESCRIPTION

B7DBP

B7EDBP

Double pushbutton (Start/Stop)

B7CT100

—

Control transformer 100VA (0,1,2)*

B7RPL

B7ERPL

Red pilot light 120 Volt

B7CT150

—

Control transformer 150VA (0,1,2)*

B7GPL

B7EGPL

Green pilot light 120 Volt

B7CT200

—

Control transformer 200VA (3,4)*

B7APL

B7EAPL

Amber pilot light 120 Volt

B7CT250

—

Control transformer 250VA (3,4)*

B7LPBR

B7ELPBR

Illuminated red pushbutton 120 Volt

—

B7CT300

Control transformer 300VA (5)*

B7LPBG

B7ELPBG

Illuminated green pushbutton 120 Volt

—

B7CT500

Control transformer 500VA (5)*

B7LPBA

B7ELPBA

Illuminated amber pushbutton 120 Volt

KB1B

KB1B

Breather** (not CSA)

B7PLR220

B7PLR220

Pilot light resistor 220 Volt to 110 Volt

KB1D

KB1D

Drain** (not CSA)

B7PLR440

B7PLR440

Pilot light resistor 440 Volt to 110 Volt

K I T- 2 5 1

K I T- 2 5 1

Grounding kit

B7PLR550

B7PLR550

Pilot light resistor 550 Volt to 110 Volt

B7SF

B7SF

Special finish - Baked epoxy outside

B72SS

B7ESS

2 position selector switch ( On-Off )

B7DLO

B7DLO

Delete lock “”ON”” feature for breaker handle

B7SSHOA

B7ESSHOA

3 position selector switch ( Hand-Off-Auto )

B7SH251

B7SH251

Space heater 25 Watt 120 Volt

B7HAC

B75CAC

Cutler Hammer auxiliar y contact (1NO/1NC)

B7SH252

B7SH252

Space heater 25 Watt 240 Volt

B7SAC

B75SAC

Square D auxiliar y contact (1NO/1NC)

B7SH254

B7SH254

Space heater 25 Watt 480 Volt

B7TB

B7TB

Terminal block ( 6 Terminals )

B7SH501

B7SH501

Space heater 50 Watt 120 Volt

—

B7IPR

Interposing relay 120 Volt coil

B7SH502

B7SH502

Space heater 50 Watt 240 Volt

B7CT50

—

Control transformer 50VA (0,1,2)*

B7SH504

B7SH504

Space heater 50 Watt 480 Volt

B7CT75

—

Control transformer 75VA (0,1,2)*

* Control transformers are primary 240/480 - Secondary 120 Volt. Control
transformers for use on Combination Starters Only. Will not fit into
B701 Series of Non-Combination Starters.
* All control transformers include fused primary and secondary circuits.
** Installation of drains and breathers will void the NEMA4-4x ratings - voids Group B for CSA.

Catalog Logic – B7 Enclosures with Controls
B7

Series
Constant

Starter Type
01—Non-Combination
(SSNR)
02—Combination
(SSNR)

Starter Size
0
1
2
3
4

Starter Coil Voltage
A—110V-60HZ
B—120/110V-60/50HZ
C—120/240V=60/50HZ
D—208/220V-60HZ
E—208/220/480V-60HZ
F—220V-60HZ
G—240/220V-50/60HZ
H—240/480V-60HZ
J—440/380V-60/50HZ
K—480/440V-60/50HZ
L—550V-60HZ
M—600/550V-60/50HZ
N—600V-50HZ
V—Specify Voltage

Disconnect Means
A—Sq. D. FAL Mag Guard
B—Sq. D. KAL Mag Guard
C—Cutler-Hammer HMCP Motor C.R. Protector
D—Sq. D. FAL Thermal Magnetic
E—Sq. D. FHL Thermal Magnetic
F—Sq. D. FCL Thermal Magnetic
G—Sq. D. KAL Thermal Magnetic
H—Sq. D KHL Thermal Magnetic
J—Sq. D. KCL Thermal Magnetic
K—Cutler-Hammer EHD Thermal Magnetic
L—Cutler-Hammer FDB Thermal Magnetic
M—Cutler-Hammer FD Thermal Magnetic
N—Cutler-Hammer HFD Thermal Magnetic
P—Cutler-Hammer FDC Thermal Magnetic

Starter Manufacturer
S—Square D
H—Cutler-Hammer (Freedom)

This Catalog Logic Chart is for reference only and is to be used for selection of special voltage and amperage requirements.
Consult Factory since not all assemblies are available with complete list of options displayed.

Disconnect
Current Rating
A—3 AMP
B—7 AMP
C—15 AMP
D—20 AMP
E—25 AMP
F—30 AMP
G—35 AMP
H—40 AMP
J—45 AMP
K—50 AMP
L—60 AMP
M—70 AMP
N—80 AMP
P—90 AMP
Q—100 AMP
R—110 AMP
S—125 AMP
T—150 AMP
U—175 AMP
V—200 AMP
W—225 AMP
X—250 AMP

C49

O V E R L O A D H E AT E R S / N O N - R E V E R S I N G • C O N T R O L S
3 - P O L E , 6 0 H Z , 6 0 0 VA C S I N G L E - S P E E D
Overload heaters are not
supplied as part of the
starter assemblies and are
to be ordered as separate
items by catalog number
and priced accordingly.
Heaters should be selected
on the basis of the actual
full-load current and service
factor as shown on the

motor nameplate or in the
manufacturer’s published literature.
When motor and overload
relay are in the same ambient and the service factor of
the motor is 1.15 to 1.25,
select heaters from the
heater selection chart. If
the service factor of the

motor is 1.0, or there is no
service factor shown, or a
maximum of 115% protection is desired, select one
size smaller heater than
indicated.
When motor and overload
relay are in different ambients, select heaters from the
chart using adjusted motor

currents as follows:
decrease rated motor current 1% for each ÞC motor
ambient exceeds controller
ambient; increase rated
motor current 1% for each
ÞC controller ambient
exceeds motor ambient.

S Q U A R E D 8 5 3 6 S E R I E S S TA R T E R S S S N R N E M A S I Z E S 0 - 1 T H R O U G H 5
CATALOG
NUMBER
KB044
KB051
KB057
KB063
KB071
KB081
KB092
KB103
KB116
KBI30
KBI45
KB167
KB188
KB210
KB240
KB265
KB330
KB300
KB370
KB415
KB485
KB550
KB625
KB690
KB770
KB820
KB910
KB102
KB115
KB128
KB014
KB155
KB175
KB195
KB022

FULL-LOAD
CURRENT (AMPS)

FOR SIZE 0-1
0.28-0.30
0.31-0.34
0.35-0.37
0.38-0.44
0.45-0.53
0.54-0.59
0.60-0.64
0.65-0.72
0.73-0.80
0.81-0.90
0.91-1.03
1.04-1.14
1.15-1.27
1.28-1.43
1.44-1.62
1.63-1.77
1.78-1.97
1.98-2.32
2.33-2.51
2.52-2.99
3.00-3.42
3.43-3.75
3.76-3.98
3.99-4.48
4.49-4.93
4.94-5.21
5.22-5.84
5.85-6.67
6.68-7.54
7.55-8.14
8.15-8.72
8.73-9.66
9.67-10.5
10.6-11.3
11.4-12.0

CATALOG
NUMBER
KB022
KB025
KB280
KB032
KB036
KB040
KB045
KB050
KB485
KB550
KB625
KB690
KB770
KB820
KB910
KB102
KB115
KB128
KB014
KB155
KB175
KB195
KB022
KB025
KB280
KB032
KB036
KB040
KB045
KB050
KB056
KB062
KB070
KB079
KB088

FULL-LOAD
CURRENT (AMPS)

CATALOG
NUMBER

FOR SIZE 1
11.4-12.7
12.8-14.1
14.2-15.9
16.0-17.5
17.6-1 9.7
19.8-21.9
22.0-24.4
24.5-26.0
FOR SIZE 2
3.18-3.40
3.41-3.76
3.77-4.00
4.01-4.57
4.58-5.03
5.04-5.32
5.33-5.97
5.98-6.88
6.89-7.82
7.83-8.47
8.48-9.15
9.16-10.1
10.2-11.2
11.3-12.0
12.1-13.6
13.7-15.2
15.3-17.1
17.2-19.0
19.1-21.5
21.6-24.1
24.2-27.0
27.1-28.7
28.8-30.4
30.5-32.2
32.3-35.4
35.5-38.2
38.3-45.0

KCC209
KCC228
KCC246
KCC263
KCC288
KCC310
KCC333
KCC364
KCC396
KCC427
KCC466
KCC501
KCC545
KCC594
KCC643
KCC685
KCC749
KCC815
KCC877
KCC940
KCC103
KCC112
KCC121
KCC132
KCC143
KCC156
KCC167
KCC180
KCC196

FULL-LOAD
CURRENT (AMPS)

CATALOG
NUMBER

FOR SIZE 3
13.6-14.5
14.6-15.5
15.6-17.4
17.5-18.5
18.6-19.9
20.0-21.5
21.6-22.9
23.0-24.5
24.6-26.3
26.4-28.2
28.3-30.0
30.1-32.3
32.4-34.9
35.0-37.6
37.7-40.0
40.1-42.8
42.9-45.3
45.4-49.1
49.2-53.4
53.5-57.4
57.5-61.3
61.4-63.5.
63.6-66.3
66.4-69.0
69.1-70.9
71.0-73.7
73.8-76.5
76.6-78.4
78.5-86.0

KCC643
KCC685
KCC746
KCC815
KCC877
KCC940
KCC103
KCC112
KCC121
KCC132
KCC143
KCC156
KCC167
KCC180
KCC196
KCC208
KCC219
KDD112
KDD121
KDD128
KDD140
KDD150
KDD160
KDD185
KDD220
KDD240
KDD250
KDD265
KDD280
KDD300
KDD320
KDD320

FULL-LOAD
CURRENT (AMPS)
FOR SIZE 4
41.1-43.5
43.6-46.8
46.9-50.0
50.1-54.9
55.0-57.5
57.6-61.8
61.9-66.2
66.3-72.4
72.5-78.1
78.2-80.7
80.8-86.5
86.6-93.9
94.0-100
101.-112.
113.-117.
118.-123.
124.-133.
FOR SIZE 5
82.5-88.2
88.3-95.9
96.0-102.
103.-109.
110.-121.
122.-139.
140.-154.
155.-163.
164.-175.
176.-184.
185.-195.
196.-215.
216.-224.
225.-243.
244.-266.

C

NOTE: Square D 8536 series starters SSNR ambient compensated 20ÞC to 60ÞC block type overload using 3 heaters.
Three required for each starter.
C U T L E R - H A M M E R H E AT E R ( E A C H H E AT E R P A C K C O N S I S T S O F 3 H E AT E R S )
CATALOG
NUMBER

KH2001B-3
KH2002B-3
KH2003B-3
KH2004B-3
KH2005B-3
KH2006B-3
KH2007B-3
KH2008B-3
KH2009B-3
KH2010B-3
KH2011B-3
KH2012B-3
KH2013B-3
KH2014B-3

MOTOR FULL-LOAD AMPERE RATING
DIAL POSITION
A
B
FOR SIZES 0-1
.306
.254
.452
.375
.676
.560
.983
.814
1.45
1.20
2.16
1.79
2.60
2.15
3.90
3.23
5.50
4.55
8.17
6.75
10.8
9.14
16.9
14.0
22.7
18.7
28.5
23.5

C
.359
.530
.791
1.15
1.71
2.53
3.04
4.56
6.45
9.58
12.4
19.9
26.7
33.5

D
.411
.607
.907
1.32
1.96
2.90
3.49
5.23
7.40
11.0
14.0
22.8
30.7
38.5

CATALOG
NUMBER

KH2015B-3
KH2016B-3
KH2017B-3
KH2018-3
KH2019-3
KH2020-3
KH2021-3
KH2022-3
KH2023-3
KH2024-3
KH2004B-3
KH2005B-3
KH2006B-3
KH2007B-3
KH2008B-3

MOTOR FULL-LOAD AMPERE RATING
DIAL POSITION
A

B

FOR SIZE 2
34.0
29.0
45.5
39.6
60.9
53.9
FOR SIZES 3-4
20.2
18.0
27.6
24.6
37.5
33.5
51.2
45.7
69.7
62.2
95.0
84.7
118.0
106.0
FOR SIZE 5
59
49
87
72
130
107
156
129
234
194

C

D

39.1
51.5
67.9

44.1
57.4
74.9

22.3
30.5
41.5
56.7
77.1
105.0
131.0

24.5
33.4
45.6
62.1
84.6
115.0
144.0

69
103
152
182
274

79
118
174
209
---

C50

Y7 SERIES • CONTROLS
M O T O R S TA R T E R S - M A G N E T I C L I N E S TA R T E R S

Class I, Div. I & 2, Groups C,D
Class 1, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Certified - File LR11714
FM

APPROVED

Y7011ZH

Contact Killark for FM file numbers.
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Applications
• Hazardous areas due to the presence of flammable gases or vapors,
combustible dusts or easily ignitable
fibers or flyings
• Installations at petroleum refineries,
chemical and petrochemical plants,
storage areas and other processing
facilities where hazardous substances are handled or stored
• Full-voltage, across-the-line starting
and stopping of polyphase AC squirrel cage induction motors or as the
primary starter for wound rotor
motors
• Provides running and undervoltage
protection of motor
• Remote starting and stopping of
motor
Features
• Rectangular bolted cover design provides for attractive, compact, uniform
installations
• Ground flange joint between box and
cover provides required flame path
• Two drilled and tapped power conduit openings, one top and one bottom are standard on all assemblies.
• One 3/4"-14 NPT drilled, tapped and
plugged conduit opening is provided
in bottom for remote control
• Two 3/4"-14 NPSM drilled, tapped,
and plugged openings in cover are
provided for addition of local control
operator

• External reset button and stainless
steel cover bolts are standard
• Hinges are either stainless steel or
aluminum and are mounted on the
left side of all assemblies
• Enclosure is cast copper-free aluminum alloy
• Available for Cutler-Hammer AN16
Freedom or Square D 8536 starters

Overload Heaters
Heaters not included. See page C49
for heater selection
Dimensions
See page C52 for dimensional data
Modifications
See page C52

Y 7 M A G N E T I C L I N E S TA R T E R
( E N C L O S U R E S W I T H O U T S PA C E F O R C O N T R O L T R A N S F O R M E R )
NEMA
STARTER
SIZE

MOTOR
VOLTS

0
0

CATALOG NUMBER

COIL
VOLTS

MAXIMUM
HP

Sep Control

120

—

Y7010BH

Y7010BS

230

240

3

Y7010DH

Y7010DS

0

440-460

480

5

Y7010KH

Y7010KS

1

Sep Control

120

—

Y7011BH

Y7011BS

1

230

240

7-1/2

Y7011DH

Y7011DS

1

440-460

480

10

Y7011KH

Y7011KS

2

Sep Control

120

—

Y7012BH

Y7012BS

2

230

240

15

Y7012DH

Y7012DS

2

440-460

480

25

Y7012KH

Y7012KS

CUTLER-HAMMER
SERIES AN16

SQUARE D
SERIES 8536

0

Enclosure only No interior

Y7010ZH

Y7010ZS

1

Enclosure only No interior

Y7011ZH

Y7011ZS

2

Enclosure only No interior

Y7012ZH

Y7012ZS

Y 7 M A G N E T I C L I N E S TA R T E R
( E N C L O S U R E S W I T H S PA C E F O R C O N T R O L T R A N S F O R M E R )
NEMA
STARTER
SIZE

MOTOR
VOLTS

COIL
VOLTS

MAXIMUM
HP

CATALOG NUMBER
CUTLER-HAMMER
SERIES AN16

SQUARE D
SERIES 8536

0

230//460

120

3//5

Y7000BH

Y7000BS

1

230//460

120

7 1/2//10

Y7001BH

Y7001BS

2

230//460

120

15//25

Y7002BH

Y7002BS

0

Enclosure only No interior

Y7000ZH

Y7000ZS

1

Enclosure only No interior

Y7001ZH

Y7001ZS

2

Enclosure only No interior

Y7002ZH

Y7002ZS

C51

Y7 SERIES • CONTROLS
C O M B I N AT I O N M O T O R S TA R T E R S

Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Certified - File LR11714
FM
APPROVED

Y7021ZHAZ

Contact Killark for FM file numbers.
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Applications
• Hazardous areas due to the
presence of flammable gases or
vapors, combustible dusts or
easily ignitable fibers or flyings
• Full-voltage, across-the-line
starting and stopping of
polyphase AC squirrel cage
induction motors or as the primary starter for wound rotor
motors
• Provides running and undervoltage protection of motor
• Motor branch circuit disconnect
and short circuit protection
Features
• Rectangular bolted cover design
provides for attractive, compact,
uniform installations
• Two 3/4"-14 NPSM drilled,
tapped, and plugged openings
are provided for addition of local
operators
• Two drilled, tapped and plugged
openings, one top and one bottom are supplied for installation
of drain and breather
• Hinges are either stainless steel
or aluminum and are mounted
on the left side of all assemblies
• Circuit breaker handle mechanism interlocks with circuit
breaker to prevent opening of
enclosure when circuit is in the
“ON” position

• External handle is vault type with
standard provisions for locking in the
“OFF” position with up to three padlocks
• Circuit breaker is trip free of handle
mechanism

Dimensions
For dimensional data, see page C52.
Overload Heaters
Heaters are not included.
See page C49 for heater selection.

Modifications
Modifications are available.
See page C52.
Y 7 C O M B I N AT I O N M A G N E T I C L I N E S TA R T E R
NEMA
STARTER
SIZE

MOTOR
VOLTS

0

Sep Control

120

-

0

Sep Control

120

-

0

Sep Control

120

0

230

0

COIL
VOLTS

MAXIMUM
HP

DISCONNECT
TRIP
AMPS

CATALOG NUMBER
CUTLER-HAMMER
SERIES AN16

SQUARE D
SERIES 8536

3

Y7020BHVV

Y7020BSVV

7

Y7020BHVX

Y7020BSVX

-

15

Y7020BHVA

Y7020BSVA

240

1

7

Y7020DHVX

Y7020DSVX

230

240

3

15

Y7020DHVA

Y7020DSVA

0

460

480

1

3

Y7020KHVV

Y7020KSVV

0

460

480

5

7

Y7020KHVX

Y7020KSVX

1

Sep Control

120

-

15

Y7021BHVA

Y7021BSVA

1

Sep Control

120

-

30

Y7021BHVC

Y7021BSVC

1

230

240

7-1/2

30

Y7021DHVC

Y7021DSVC

1

460

10

30

Y7021KHVC

Y7021KSVC

2

Sep Control

120

50

Y7022BHVE

Y7022BSVE

2

Sep Control

120

70

Y7022BHVG

Y7022BSVG

2

230

240

15

50

Y7022DHVE

Y7022DSVE

2

230

240

15

70

Y7022DHVG

Y7022DSVG

2

460

480

25

50

Y7022KHVE

Y7022KSVE

480

-

0

Enclosure only. No Interior

Y7020ZHVZ

Y7020ZSVZ

1

Enclosure only. No Interior

Y7021ZHVZ

Y7021ZSVZ

2

Enclosure only. No Interior

Y7022ZHVZ

Y7022ZSVZ

C

C52

Y7 SERIES • CONTROLS
M O T O R S TA R T E R S / M O D I F I C AT I O N S

Combination Starter Modifications
Modifications are available by ordering the
following by catalog number as separate
items and noting on the order that they are
to be assembled into the enclosure.

F E AT U R E S - S P E C I F I C AT I O N S

Y 7 M A G N E T I C L I N E S TA R T E R S D I M E N S I O N S
NEMA
SIZE

0-1 1

21

0-1 2
22

A

B

D

E
6"(152)

G

H

J

CONDUIT SIZE
POWER
CONTROL

K

7-3/4"(197)

7-1/4"(184)

10"(254)

2"(51)

7-5/8"(194)

1-1/8"(28)

3/4"(19)

1-1/2"

3/4"

9"(228)

7-3/4"(197)

11-1/4"(286)

6-1/2"(165)

2"(51)

7-5/8"(194)

1-1/8"(28)

7/8"(22)

1-1/2"

3/4"

8-3/4"(222)

11-1/8"(282)

12-1/2"(317)

10-1/2"(267)

2"(51)

8-1/4"(209)

2-3/8"(60)

2-3/8"(60)

1-1/2"

3/4"

8-3/4"(222)

11-1/8"(282)

12-1/2"(317)

10-1/2"(267)

2"(51)

8-1/4"(209)

2-3/8"(60)

2-3/8"(60)

1-1/2"

3/4"

H

J

1 Without space for control transformer. 2 With space for control transformer.

Y 7 C O M B I N AT I O N S TA R T E R S D I M E N S I O N S
NEMA
SIZE

A

B

D

E

G

CONDUIT SIZE
POWER
CONTROL

0-1

16-1/4"(413)

11-1/8"(282)

20"(508)

10-1/2"(267)

2"(51)

9"(228)

2-3/8"(60)

1-1/2"

3/4"

2

16-1/4"(413)

11-1/8"(282)

20"(508)

10-1/2"(267)

2"(51)

9"(228)

2-3/8"(60)

1-1/2"

3/4"

Dimensions

Y 7 M O D I F I C AT I O N S A N D A C C E S S O R I E S
DESCRIPTION

CATALOG NUMBER

Magnetic Line Starters
Sizes 0, 1, 2

GO22-GR12D

Double pushbutton (Start/Stop)

GOB3-R23C N34

Red pilot light 120 Volt

GOB3-G23C N34

Green pilot light 120 Volt

GOB3-A23C N34

Amber pilot light 120 Volt

B7PLR220

Pilot light resistor 220 Volt to 120 Volt

B7PLR440

Pilot light resistor 440 Volt to 120 Volt

B7PLR550

Pilot light resistor 550 Volt to 120 Volt

GO25-2A3F

2 position selector switch (On/Off)

GO25-3C3G

3 position selector switch (Hand/Off/Auto)

B7HAC

Cutler-Hammer auxiliar y contact (1NO/1NC)

B7SAC

Square D auxiliar y contact (1NO/1NC)

B7CT50

Control transformer 50VA*

B7CT75

Control transformer 75VA*

B7CT100

Control transformer 100VA*

KDB-1

Breather

KDB-1

Drain

KIT-251

Grounding kit

* Control transformers are primary 240/480 - Secondary 120 Volt.
* All control transformers include fused primary and secondary circuits.

Combination Starters
Sizes 0, 1, 2

C53

XSD/XSX/FXSD/FXSX SERIES • CONTROLS
M A N U A L M O T O R S TA R T I N G S W I T C H E S

Class I, Div. 1 & 2, Groups C,D
Class 1, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
NEMA 3 (Factory sealed type)
Listed - File E53360 and/or E12379
Certified - File LR11714

XSD, XSX, Series
Non Factory Sealed

FM – File 25219

FM

FXSD, FXSX Series
Factory Sealed

APPROVED

See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Applications
• Provides manual starting and stopping of small AC or DC motors
• Motor running protection when overload heaters are used
• XSX/FXSX Series (without overload
protection) are ideally suited for
across-the-line applications where a
positive disconnect means is
required
Features
• FXSX-FXSD Series require no external seals (factory sealed) and are
NEMA 3 (raintight) rated
• Enclosures are cast copper-free
aluminum alloy
• Operating shaft is stainless steel
• Multiple gang assemblies available in
combination with pilot lights, pushbuttons and switches on request
• Ground flange joint between bolted
cover and box provide required flame
path
• Provisions for padlocking switch in
either “ON” or ”OFF” position is standard
Dimensions
For dimensional data, see page C54.

XSD/FXSD SERIES WITH OVERLOAD PROTECTION1

Factory Sealed:
Square D, Class 2510, Type F
1-Pole, 1HP, 115-230 VAC
2-Pole, 1HP, 115-230 VAC
3/4 HP, 115-230 VDC

Non-Factory Sealed:
Square D, Class 2510, Type F
1-Pole, 1HP, 115-230 VAC
2-Pole, 1HP, 115-230 VAC
3/4 HP, 115-230 VDC
XSD SINGLE GANG2
CATALOG NUMBER
1-POLE
2-POLE
SINGLE
SINGLE
PHASE
PHASE
XSD-11

XSD-12

XSD-21

XSD-22

XSD-41

XSD-42

XSD-51

XSD-52

XSD-01

XSD-02

FXSD SINGLE GANG
HUB
STYLE

HUB
SIZE

CATALOG NUMBER
1-POLE
2-POLE
SINGLE
SINGLE
PHASE
PHASE

Dead
end

1/2"

FXSD11

FXSD12

3/4"

FXSD21

FXSD22

1/2"

FXSD41

FXSD42

3/4"

FXSD51

FXSD52

FXSD01

FXSD02

Feed
thru

Cover and Switch assembly

HUB
STYLE

HUB
SIZE

Dead
end

1/2"

Feed
thru

1/2"

3/4"
3/4"

Cover and Switch assembl y

1 Order heaters separately on page C54.
2 FM and CSA only

C

XSX/FXSX SERIES WITHOUT OVERLOAD PROTECTION

Non-Factory Sealed:
Square D, Class 2510, Type K
2-Pole, 2 HP, 115 VAC
2 HP, 200-230 VAC
3 HP, 460-575 VAC
3-Pole, 2 HP, 115 VAC
7-1/2 HP, 200-230 VAC
10 HP, 460-575 VAC
XSX SINGLE GANG1
CATALOG NUMBER
2-POLE
3-POLE
30A., 250V 30A., 250V
20A., 600V 20A., 600V
1-PHASE
3-PHASE
XSX-12

XSX-13

XSX-22

XSX-23

XSX-42

XSX-43

XSX-52

XSX-53

XSX-2

XSX-3

1 FM and CSA only

Factory Sealed:
Square D, Class 2510, Type K
2-Pole, 2 HP, 115 VAC
2 HP, 200-230 VAC
3 HP, 460-575 VAC
3-Pole, 2 HP, 115 VAC
3 HP, 200-230 VAC
5 HP, 460-575 VAC
FXSX SINGLE GANG

HUB
STYLE

HUB
SIZE

CATALOG NUMBER
2-POLE
3-POLE
30A., 250V 30A., 250V
20A., 600V 20A., 600V
1-PHASE
3-PHASE

Dead
end

1/2"

FXSX12

FXSX13

3/4"

FXSX22

FXSX23

Feed
thru

1/2"

FXSX42

FXSX43

3/4"

FXSX52

FXSX53

Cover and Switch assembly

FXSX02

FXSX03

HUB
STYLE

HUB
SIZE

Dead
end

1/2"

Feed
thru

1/2"

3/4"
3/4"

Cover and Switch assembly

C54

XSD/XSX/FXSD/FXSX SERIES • CONTROLS
X S D / X S X / F X S D / F X S X H E AT E R S

H E AT E R TA B L E 1
FULL-LOAD
MOTOR
CURRENT

SQUARE D
HEATER
CATALOG
NUMBER

YOSD-A.49

0.41-0.44

A.49

YOSD-A.54

0.45-0.49

A.54

YOSD-A.59

0.50-0.53

A.59

YOSD-A.65

0.54-0.58

A.65

YOSD-A.71

0.59-0.65

A.71

YOSD-A.78

0.66-0.71

A.78

YOSD-A.86

0.72-0.78

A.86

YOSD-A.95

0.79-0.85

A.95

YOSD-A1.02

0.86-0.96

A1.02

YOSD-A1.16

0.97-1.04

A1.16

YOSD-A1.25

1.05-1.16

A1.25

YOSD-A1.39

1.17-1.29

A1.39

YOSD-A1.54

1.30-1.37

A1.54

YOSD-A1.63

1.38-1.47

A1.63

YOSD-A1.75

1.48-1.56

A1.75

YOSD-A1.86

1.57-1.65

A1.86

YOSD-A1.99

1.66-1.79

A1.99

YOSD-A2.15

1.80-1.95

A2.15

YOSD-A2.31

1.96-2.15

A2.31

YOSD-A2.57

2.16-2.38

A2.57

YOSD-A2.81

2.39-2.75

A2.81

YOSD-A3.61

2.76-2.84

A3.61

YOSD-A3.95

2.85-3.06

A3.95

YOSD-A4.32

3.07-3.45

A4.32

YOSD-A4.79

3.46-3.70

A4.79

YOSD-A5.30

3.71-4.07

A5.30

YOSD-A5.78

4.08-4.32

A5.78

YOSD-A6.20

4.33-4.90

A6.20

YOSD-A6.99

4.91-5.35

A6.99

YOSD-A7.65

5.36-5.85

A7.65

YOSD-A8.38

5.86-6.41

A8.38

YOSD-A9.25

6.42-6.79

A9.25

YOSD-A9.85

6.80-7.57

YOSD-A11.0

7.58-8.15

A11.0

YOSD-A11.9

8.16-8.98

A11.9

YOSD-A13.2

8.99-9.67

A13.2

YOSD-A14.1

9.68-9.95

A14.1

YOSD-A14.8

9.96-10.8

A14.8

YOSD-A16.2

10.9-12.1

A16.2

YOSD-A17.9

12.2-13.1

A17.9

YOSD-A19.8

13.2-13.9

A19.8

YOSD-A21.3

14.0-15.0

A21.3

YOSD-A25.2

15.1-16.0

A25.2

CATALOG
NUMBER

F E AT U R E S - S P E C I F I C AT I O N S

X S D / X S X N O N - FA C T O RY S E A L E D D I M E N S I O N S
BOX STYLE
Single gang
dead-end
Single gang
feed-thru

HUB SIZE

starter assemblies and need to be ordered as
separate items by catalog number and priced
accordingly.

B

D

G

1/2"

5-1/4"(133)

2-1/4"(57)

—

11/16"(17)

3/4"

5-1/4"(133)

2-1/4"(57)

—

11/16"(17)

1"

5-3/8"(136)

2-3/8"(60)

—

7/8"(22)

1/2"

5-1/4"(133)

2-1/4"(57)

6"(152)

11/16"(17)

3/4"

5-1/4"(133)

2-1/4"(57)

6"(152)

11/16"(17)

1"

5-3/8"(136)

2-3/8"(60)

6"(152)

7/8"(22)

A9.85

1Overload heaters are not supplied as part of the

A

FA C T O RY S E A L E D ( F X S D / F X S X )

C55

B7MS SERIES • CONTROLS
C O M PA C T M A N U A L I E C S TA R T E R S

Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)

C

Certified - File LR11714

US

B7MS2R
Rotary Style

B7MS1P
Push Button Style

F E AT U R E S - S P E C I F I C AT I O N S
Applications
The PRISM® B7MS Series of non-reversing, manual line voltage starters and
enclosures are suitable for use in applications requiring manual across-the-line
starting and stopping of small single and
polyphase AC motors, and where overload protection is needed. Manual starters
are generally used on small machine
tools, fans and blowers, pumps, compressors, and conveyors as well as many
other types of electrical equipment.

Features
• Compact size enclosures provide
application flexibility with cost savings
over industry standard sizes
• NEMA 4, 4X rated - providing protection from hose directed water and
corrosion
• Pre-drilled to facilitate easy field
installation of starters
• 2 operating styles, rotary or push
button, including lock-out provision.
• Provisions for drain and breather
• Bi-directional ductile mounting lugs
• Two NPT conduit openings provided
as standard, with custom openings
on request

PRISM® enclosures universal design
accommodates, as standard, IEC starter
manufacturers including Square D, CutlerHammer, ABB, Siemens, Moeller,
Sprecher + Schuh, Allen-Bradley,
Advance Controls, and WEG.
Square D © Schneider Electric
Siemens © Siemens AG
Moeller © Moeller Electric Corp.
See catalog pg. DE8A for copyrights of other
brands referenced.

Catalog Logic

B7MS

1

Standard Materials / Finish
• Enclosures: Copper-free aluminum
(less than 4/10 of 1% copper content)
• Cover Bolts: 316 Stainless Steel
• O-ring Gasket: Silicone
• Finish: Grey Powder Polyester painted
exterior, electrostatically applied

When ordered with starters, ABB or
Square D supplied.

M O D I F I C AT I O N S
SUFFIX
NUMBER

Electrical Rating
• Starters rated 600V, 3 phase up to 50HP

R

S

1

DESCRIPTION

KIT-251

100 amp ground lug

A

Auxiliary contacts 1 NO + 1 NC

SU-2

Hinge-9 Installed

SU3*

Drain & Breather installed (NEMA 7CD)

SU3B*

Drain & Breather installed (NEMA 7BCD)

B7SPNPT

Change Std. conduit size and location

SU9

Special paint finish

SU14

Fungus proofing of enclosures

*NOTE: The installation of a Drain & Breather will void the
NEMA 4-4X rating of enclosure.

A

Constant for Series
Enclosure Size
1 = B7EP
2 = B7EQ
Operating Device
R = Rotary
P = Push Buttons
Starter Manufacturer
to be supplied
S = Square D
A = ABB
Blank = Enclosure only
Horsepower (FLA) of starter
Accessories
A = Aux. Contacts NO + NC

DIMENSIONS
Fixed Lug Position For B7MS1
Optional Position For B7MS2
Standard Lug Position For B7MS2

Enclosure

OUTSIDE BOX
DIMENSIONS
A

B

C

NOMINAL
INSIDE BOX
D

E

F

MOUNTING
DIMENSIONS
G

H

CONDUIT
SIZE

I

J

K

-

-

-

1-1/4

1

B7MS1

5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8

B7MS2

8-1/8 13-1/16 7-13/16 4-1/4 9-13/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16

1-1/2

C

C56

ENCLOSURE
WITHOUT
STARTER
B7MS1R
B7MS1R

ENCLOSURE
WITHOUT
STARTER
B7MS2RA
FOR USE
WITH ABB
ONLY

ENCLOSURE
WITHOUT
STARTER

B7MS1P*

ENCLOSURE
WITHOUT
STARTER
B7MS2P

ENCLOSURE
WITHOUT
STARTER

B7MS1R

B7MS SERIES • CONTROLS
C O M PA C T M A N U A L I E C S TA R T E R S
B7MS - ROTARY STYLE WITH ABB MS132 & MS450 SERIES
CATALOG
ADJUSTMENT
SINGLE PHASE HP
NUMBER
RANGE FLA
120V
230V
B7MS1RA-1
0.63 - 1.0
B7MS1RA-2
1.0 - 1.6
0.1
B7MS1RA-3
1.6 - 2.5
0.167
B7MS1RA-4
2.5 - 4.0
0.125
0.33
B7MS1RA-5
4.0 - 6.3
0.25
0.5
B7MS1RA-6
6.3 - 9.0
0.33
1
B7MS1RA-7
9.0 - 12.5
0.5
2
B7MS1RA-8
12.5 - 16.0
1
2.5
B7MS1RA-9
16.0 - 20.0
1.5
3
B7MS1RA-10
20.0 - 25.0
2
3
B7MS2RA-12
11 - 16
1
3
B7MS2RA-13
14 - 20
1.5
3
B7MS2RA-14
18 - 25
2
5
B7MS2RA-15
22 - 32
3
5
B7MS2RA-16
28 - 40
3
7.5
B7MS2RA-17
36 - 45
5
7.5
B7MS2RA-18
40 - 50
5
10
B7MS - PUSH BUTTON STYLE SQUARE D GV2 SERIES
CATALOG
ADJUSTMENT
SINGLE PHASE HP
NUMBER
RANGE FLA
120V
230V
B7MS1PS-1
0.63 - 1.0
B7MS1PS-2
1.0 - 1.6
0.1
B7MS1PS-3
1.6 - 2.5
0.167
B7MS1PS-4
2.5 - 4.0
0.125
0.33
B7MS1PS-5
4.0 - 6.3
0.25
0.5
B7MS1PS-6
6.0 - 10.0
0.5
1.5
B7MS1PS-7
9.0 - 14.0
0.75
2
B7MS1PS-8
13.0 - 18.0
1
3
B7MS1PS-9
17.0 - 23.0
1.5
3
B7MS1PS-10
20.0 - 25.0
2
3
B7MS1PS-11
24.0 - 32.0
2
5
B7MS2PS-12
10.0 - 16.0
1
2
B7MS2PS-14
16.0 - 25.0
2
3
B7MS2PS-16
25.0 - 40.0
3
7.5
B7MS2PS-18
40.0 - 63.0
5
10
B7MS - ROTARY STYLE WITH SQUARE D GV2 & GV3 SERIES
CATALOG
ADJUSTMENT
SINGLE PHASE HP
NUMBER
RANGE FLA
120V
230V
B7MS1RS-1
0.63 - 1.0
B7MS1RS-2
1.0 - 1.6
0.1
B7MS1RS-3
1.6 - 2.5
0.167
B7MS1RS-4
2.5 - 4.0
0.125
0.33
B7MS1RS-5
4.0 - 6.3
0.25
0.5
B7MS1RS-6
6.0 - 10.0
0.5
1.5
B7MS1RS-7
9.0 - 14.0
0.75
2
B7MS1RS-8
13.0 - 18.0
1
3
B7MS1RS-9
17.0 - 23.0
1.5
3
B7MS1RS-10
20.0 - 25.0
2
3
B7MS1RS-11
24.0 - 32.0
2
5

200V-208V

230V

5
5
7.5
10
15
15
15

0.5
1
1.5
2.5
3
5
5
7.5
5
7.5
10
10
15
15
20

200V-208V

230V

0.5
0.75
1.5
2
3
5
5
5
10
3
5
10
20

0.5
1
1.5
3
3
5
7.5
7.5
10
5
7.5
10
20

200V-208V

230V

0.5
0.75
1.5
2
3
5
5
5
10

0.5
1
1.5
3
3
5
7.5
7.5
10

ENCLOSURE
WITHOUT
STARTER
B7MS2R

B7MS1R - For use with ABB
MS116, MS325, MS132
Automation Direct BM3
Cutler-Hammer XTPR
Moeller PKZMO
Seimens 3RV
Sprecher + Schuh KTA7
SQ D Telemecanique GV2P
WEG MPW25

B7MS2R - For use with
Automation Direct BM3
B7MS2RA - For use with ABB
MS450
B7MS1P - For use with
Cutler-Hammer XTPB
Moeller PKZMO1
SQ D Telemecanique GV2ME
WEG MPW25

B7MS2P - For use with
Advance Control MMS25
* B7MS1PRW - (enclosure
without starter) For use with
Allen-Bradley 140
Sorecher + Schuh KT4

THREE PHASE HP
480V 600V
0.5
0.5
0.75
0.75
1
1.5
2
3
3
5
5
7.5
7.5
10
10
10
10
15
15
20
10
15
15
20
20
25
25
30
30
40
30
40
40
50

THREE PHASE HP
480V 600V
0.5
0.5
0.75
1
1
1.5
2
3
3
5
5
7.5
10
10
10
15
15
20
15
20
20
30
10
10
15
20
25
30
40
50

THREE PHASE HP
480V 600V
0.5
0.5
0.75
1
1
1.5
2
3
3
5
5
7.5
10
10
10
15
15
20
15
20
20
30

C57

B7MS SERIES • CONTROLS
C O M PA C T M A N U A L N E M A S TA R T E R S

Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)

C

B7MSN2P

US

Certified - File LR11714

INTERNAL VIEW

F E AT U R E S - S P E C I F I C AT I O N S
Applications
PRISM®

The
B7MSN Series of nonreversing, manual line voltage starters
and enclosures are suitable for use in
applications requiring manual across-theline starting and stopping of small single
and polyphase AC motors, and where
overload protection is needed. Manual
starters are generally used on small
machine tools, fans and blowers, pumps,
compressors, and conveyors as well as
many other types of electrical equipment.
PRISM® enclosures universal design
accommodates, as standard, starter
manufacturers including
• Allen-Bradley 609 Series
• Cutler-Hammer B100M Series
• GE CR106 Series
• Square D 2510M Series

CATALOG NUMBER
ENCLOSURE W/CUTLER-HAMMER W/SQUARE D

B7MSN2P
B7MSN2PC0C
B7MSN2PC1C

** = INCLUDES 380VAC

Enclosure

B7MSN2P

• Compact size enclosures provide
application flexibility with cost savings
over industry standard sizes
• NEMA 4, 4X rated - providing protection from hose directed water and
corrosion
• Pre-drilled to facilitate easy field
installation of starters
• Large double green/red start-stop
push buttons
• Can be pad locked in “OFF” position
• Provisions for drain and breather
• Bi-directional ductile mounting lugs
• Two 1-1/2” NPT conduit openings provided as standard, with custom open
ings on request

• Enclosures: Copper-free aluminum
(less than 4/10 of 1% copper content)
• Cover Bolts: 316 Stainless Steel
• O-ring Gasket: Silicone
• Finish: Grey Powder Polyester painted
exterior, electrostatically applied

SIZE/PHASE

B7MSN2PS0B
B7MSN2PS1B
B7MSN2PSDB
B7MSN2PS0C
B7MSN2PS1C
B7MSN2PS0V
B7MSN2PS1V

SINGLE PHASE HP
120VAC
230VAC

M-0 2P
M-1 2P
M-1P 2P
M-0 3P
M-1 3P
M-0 2P VDC
M-1 2P VDC

1
2
3

B

C

E

F

DESCRIPTION

KIT-251
AO
AC

100 amp ground lug
Aux. contact NO only
Aux. contact NC only

SU-2

Hinge-9 Installed

SU3*

Drain & Breather installed (NEMA 7CD)

SU3B*

Drain & Breather installed (NEMA 7BCD)

B7SPNPT

Change Std. conduit size and location

SU9

Special paint finish

SU14

Fungus proofing of enclosures

*NOTE: The installation of a Drain & Breather will void the
NEMA 4-4X rating of enclosure.

THREE PHASE
DC HP
208VAC 230VAC 480VAC** 600VAC 115DC 230VDC

3
7.5

3
7.5

5
10

MOUNTING
DIMENSIONS
G

H

I

J

Standard Lug Position For B7MSN2P

K

8-1/8 13-1/16 7-13/16 4-1/4 9-13/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16

1 CH
1.5 CH

1.5 CH
2 CH

1
1.5

1.5
2

5
10

Optional Position

NOMINAL
INSIDE BOX
D

M O D I F I C AT I O N S
SUFFIX
NUMBER

2
3
5

CH = CUTLER-HAMMER ONLY

OUTSIDE BOX
DIMENSIONS
A

Standard Materials /Finish

Electrical Rating
NEMA starter sizes 0, 1, 1-1/2 FVNR;
2 pole single phase = 230 VAC
3 pole three phase = 600 VAC
2 pole VDC = 230 VDC
Overload Heaters
Heaters are not included, see next page.

Allen Bradley © Rockwell Automation
Cutler-Hammer © Eaton Corporation
GE © General Electric Company
Square D © Schneider Electric

B7MSN2PC0B
B7MSN2PC1B

Features

C

C58

B7MSN SERIES • CONTROLS
H E AT E R S , C ATA L O G L O G I C , D I M E N S I O N S

B7MSN Heater Selection1
Square D 2510M Only
Motor Full Load AMPS @ 40oC
Size 0

Catalog Logic

CATALOG
NUMBER

SINGLE
PHASE

THREE
PHASE

KB044
KB051
KB057
KB063
KB071
KB081
KB092
KB103
KB116
KB130
KB145
KB167
KB188
KB210
KB240
KB265
KB300
KB330
KB370
KB415
KB485
KB550
KB625
KB690
KB770
KB820
KB910
KB102
KB115
KB128
KB014
KB155
KB175
KB195
KB022
KB025

0.33 - 0.36
0.37 - 0.40
0.41 - 0.45
0.46 - 0.52
0.53 - 0.59
0.60 - 0.66
0.67 - 0.73
0.74 - 0.81
0.82 - 0.91
0.92 - 1.02
1.03 - 1.14
1.15 - 1.29
1.20 - 1.42
1.43 - 1.64
1.65 - 1.80
1.81 - 2.10
2.11 - 2.30
2.31 - 2.61
2.62 - 2.99
3.00 - 3.37
3.38 - 3.94
3.95 - 4.24
4.25 - 4.54
4.55 - 5.29
5.30 - 5.73
5.74 - 6.35
6.36 - 7.08
7.09 - 7.83
7.84 - 8.47
8.48 - 9.83
9.84 - 10.5
10.6 - 11.4
11.5 - 12.8
12.9 - 13.9
14.0 - 16.1
16.2 - 18.0

0.29 - 0.32
0.33 - 0.36
0.37 - 0.39
0.40 - 0.47
0.48 - 0.56
0.57 - 0.63
0.64 - 0.69
0.70 - 0.77
0.78 - 0.86
0.87 - 0.96
0.97 - 1.11
1.12 - 1.23
1.24 - 1.37
1.38 - 1.55
1.56 - 1.75
1.76 - 1.92
1.93 - 2.16
2.17 - 2.50
2.51 - 2.81
2.82 - 3.16
3.17 - 3.40
3.41 - 3.76
3.77 - 4.00
4.01 - 4.68
4.69 - 5.18
5.19 - 5.51
5.52 - 6.19
6.20 - 7.12
7.13 - 8.15
8.16 - 8.60
8.61 - 9.21
9.22 - 10.1
10.2 - 11.2
11.3 - 12.0
---------

SIZE 1 & 1P

SIZE 1 & 1P

SIZE 1 & 1P

KB195
KB022
KB025
KB280
KB032
KB036
KB040
KB045

--------16.2 - 17.6
17.7 - 20.6
20.7 - 23.1
23.2 - 26.0
---------

11.3 - 12.1
12.2 - 13.6
13.7 - 15.3
15.4 - 17.3
17.4 - 19.1
19.2 - 21.7
21.8 - 24.2
24.3 - 26.0

SIZE 1P

SIZE 1P

SIZE 1P

KB036
KB040
KB045
KB050

23.2 - 27.1
27.2 - 29.2
29.3 - 33.0
33.1 - 36.0

-----------------

1 Select heater element based on motor nameplate listed full load amps.
Trip rating of element is 125% of motor minimum F.L.A. listed for the element

B7MSN 2
P C
Constant for Series
Enclosure Size
2 = B7EQ
Operating Device
P = Push Buttons
Starter Manufacturer
C = Cutler-Hammer
S = Square D
Blank = Enclosure only
NEMA Size
O = Size Ø 1 = Size 1 D = Size 1-1/2
Number of Poles
B = 2 Pole 1 Ø (Cutler-Hammer, Sq.D only)
C = 3 Pole 3 Ø
V = 2 Pole DC
Accessories
AO = NO Aux. Contact
AC = NC Aux. Contact

1

B7MSN Heater Selections
CUTLER-HAMMER

B

A

C59

XMSW SERIES • CONTROLS
M A N U A L L I N E S TA R T E R S
C U T L E R H A M ME R / E AT O N
B 1 0 0 S TA RT E R S F U L L
V O LTA GE , N O N -R E V E R S I N G
SI N G L E A N D P O LY P H A S E
Applications
XMSW Series, non-reversing, manual
line voltage starters and enclosures are
suitable for use in applications requiring
manual across-the-line starting and
stopping of small single and polyphase
AC motors, and where overload protection is needed. Manual starters are
generally used on small machine tools,
fans and blowers, pumps, compressors,
and conveyors as well as many other
types of electrical machinery.

Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,
llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3R, 7(C,D) 9(E,F,G)
Listed - File E12379
See files for details or call Killark.

F E AT U R E S - S P E C I F I C AT I O N S
Features
• Rectangular bolted cover design
provides for attractive, compact,
uniform installations
• Enclosure and external handle are
diecast copper-free (less than 0.4%)
aluminum alloy
• Cast “ON,” “OFF,” “TRIPPED” markings
on cover align with external handle and
provide clear indication of enclosed
starter condition
• External handle is a vault type with
standard provisions for locking in the
”OFF” position with up to three
pad-locks. Provision for locking in
“ON” position is available as factory
modification (add suffix SU-40 to
catalog number).
• Two cast 1" NPT conduit hubs with
integral pipe stop, one top and
one bottom, are standard on all
assemblies
Electrical Rating
Starter sizes 0, 1, 11/2
Two pole, single phase; three pole,
polyphase
Maximum 10 HP, 600 Volts AC
Dimensions

1 Select heater element based on motor

nameplate listed. Full-load amps.
Trip rating of element is125% of motor
minimum F.L.A. listed for the element.

X M S W M A N U A L L I N E S TA R T E R S 1 2

0

2-POLE; 1Ø, A C

1

2

—

CATALOG NUMBER
WITH
ENCLOSURE
STARTER
ONLY
X M S W- 0 B T

0

3-POLE; 3Ø, A C

2

3

5

X M S W- 0 C T

1

2-POLE; 1Ø, A C

2

3

—

X M S W- 1 B T

1

3-POLE; 3Ø, A C

3

7-1/2

10

X M S W- 1 C T

1-1/2

2-POLE; 1Ø, A C

3

5

—

X M S W- D B T

NEMA
SIZE

MAXIMUM HORSEPOWER

NUMBER OF
POLE SIZE

120 VAC

208-240 VAC

480-600 VAC

X M S W- 0 0 T

1 Heaters not included. If heaters are required order as separate item by catalog number, three

phase starters require three heaters. Single phase starters require two heaters.

2 Three pole starters may be used on two-phase four-wire circuits by running one wire direct to motor.

H E AT E R TA B L E F O R X M S W S E R I E S M A N U A L L I N E S TA R T E R S 1
CATALOG
NUMBER
YOWEA200-FH03
YOWEA200-FH04
YOWEA200-FH05
YOWEA200-FH06
YOWEA200-FH07
YOWEA200-FH08
YOWEA200-FH09
YOWEA200-FH10
YOWEA200-FH11
YOWEA200-FH12
YOWEA200-FH13
YOWEA200-FH14
YOWEA200-FH15
YOWEA200-FH16
YOWEA200-FH17
YOWEA200-FH18
YOWEA200-FH19
YOWEA200-FH20
YOWEA200-FH21
YOWEA200-FH22
YOWEA200-FH23
YOWEA200-FH24
YOWEA200-FH25
YOWEA200-FH26
YOWEA200-FH27
YOWEA200-FH28
YOWEA200-FH29

MOTOR FULL-LOAD
AMPS @ 40OC
SINGLE
THREE
PHASE
PHASE
.28-.29
.30-.33
.34-.36
.37-.40
.41-.45
.46-.50
.51-.56
.57-.63
.64-.70
.71-.78
.79-.86
.87-.95
.96-1.04
1.05-1.14
1.15-1.25
1.26-1.39
1.40-1.54
1.55-1.71
1.72-1.89
1.90-2.10
2.11-2.32
2.33-2.54
2.55-2.79
2.80-3.07
3.08-3.36
3.37-3.68
3.69-4.03

.25-.26
.27-.29
.30 .32
.33-.35
.36-.39.40-.44
.45-.49
.50-.55
.56-.61
.62-.68
.69-.75
.76-.83
.84-.91
.92-1.00
1.01-1.10
1.11-1.22
1.23-1.35
1.36-1.50
1.51-1.66
1.67-1.84
1.85-2.03
2.04-2.23
2.24-2.45
2.46-2.69
2.70-2.95
2.96-3.23
3.24-3.53

CUTLER
HAMMER
FH03
FH04
FH05
FH07
FH07
FH08
FH09
FH10
FH11
FH12
FH13
FH14
FH15
FH16
FH17
FH18
FH19
FH20
FH21
FH22
FH23
FH24
FH25
FH26
FH27
FH28
FH29

CATALOG
NUMBER
YOWEA200-FH30
YOWEA200-FH31
YOWEA200-FH32
YOWEA200-FH33
YOWEA200-FH34
YOWEA200-FH35
YOWEA200-FH36
YOWEA200-FH37
YOWEA200-FH38
YOWEA200-FH39
YOWEA200-FH40
YOWEA200-FH41
YOWEA200-FH42
YOWEA200-FH43
YOWEA200-FH44
YOWEA200-FH45
YOWEA200-FH46
YOWEA200-FH47
YOWEA200-FH48
YOWEA200-FH49
YOWEA200-FH50
YOWEA200-FH51
YOWEA200-FH52
YOWEA200-FH53
YOWEA200-FH54
YOWEA200-FH55
YOWEA200-FH56
YOWEA200-FH57

MOTOR FULL-LOAD
AMPS @ 40OC
SINGLE
THREE
PHASE
PHASE
4.04-4.40
4.41-4.81
4.82 -5.26
5.27-5.74
5.75-6.25
6.27-6.83
6.84-7.45
7.46-8.11
8.12 -8.81
8.82-9.58
9.59-10.40
10.41-11.3
11.4-12.2
12.3-13.5
13.6-14.9
15.0-16.0
16.1-17.1
17.2-18.3
18.4-19.7
19.8-21.2
21.3-22.8
22.9-24.5
24.6-26.4
26.5-28.5
28.6-30.8
30.9-33.3
33.4-36.0
36.1-38.9

3.54-3.86
3.87-4.22
4.23 -4.61
4.62-5.03
5.04-5.49
5.50-5.99
6.00-6.53
6.54-7.11
7.12 -7.73
7.74-8.40
8.41-9.12
9.13-9.89
9.9-10.7
10.8-11.8
11.9-13.0
13.1-14.0
14.1-15.0
15.1-16.1
16.2-17.3
17.4-18.6
18.7-20.0
20.1-21.5
21.6-23.2
23.2-25.0
25.1-26.8
— —
— —
— —

CUTLER
HAMMER
FH30
FH31
FH32
FH33
FH34
FH35
FH36
FH37
FH38
FH39
FH40
FH41
FH42
FH43
FH44
FH45
FH46
FH47
FH48
FH49
FH50
FH51
FH52
FH53
FH54
FH55
FH56
FH57

C



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 59
Page Layout                     : SinglePage
Page Mode                       : UseNone
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Keywords                        : 
Producer                        : PDF Technologies, Inc http://www.pdf-technologies.com
Creator Tool                    : PDFTechLib 1.7.36.0 by PDF Technologies, Inc.
Create Date                     : 2014:08:27 12:47:23-04:00
Metadata Date                   : 2014:08:27 12:47:23-04:00
Modify Date                     : 2014:08:27 12:47:23-04:00
Format                          : application/pdf
Creator                         : 
Title                           : 
Description                     : 
Author                          : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu