Eds Snap Switch Control Station

2014-10-17

: Pdf 123400-Attachment 123400-Attachment 782274 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 5

DownloadEds-snap-switch-control-station
Open PDF In BrowserView PDF
EDS / EFS Series
Control Stations
Fully Assembled EFS and
EDS Factory Sealed Devices

Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Applications:

Certifications and Compliances:

Factory sealed enclosures are installed in a rigid metallic conduit
system for surface mounting adjacent to or remote from equipment
being controlled and are used:
• To prevent arcing of enclosed device from causing ignition of a
specific hazardous atmosphere or atmospheres external to the
enclosure
• In industrial areas such as chemical plants, oil and gas refineries,
paint and varnish manufacturing plants, gasoline bulk loading
terminals, grain elevators, grain processing industries, coal
processing or handling areas, or metal handling or finishing areas
where atmosphere may contain hazardous gases and/or dust
• In non-hazardous areas where sturdy, durable enclosures are
required
• In conjunction with magnetic starters or contactors for remote
control of motors
Manual motor starting switch enclosures are used:
• For manual starting of small AC or DC motors
• To provide manual starting and stopping and, in the case of units
with heaters, motor running protection

• NEC/CEC:
Class I, Division 1 & 2, Groups B*, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• NEMA/EEMAC: 3, 7B*CD, 9EFG
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Factory sealed devices have many distinct advantages:
• Reduce installation problems
• Eliminate external seals
• Lower installation costs
• Improve safety
• Are used with general purpose snap and pushbutton type switches
• Standard neoprene covers for front operated pushbuttons. Prevents
accumulation of dirt and entrance of water around operating shafts
• Mounting lugs and taper tapped hubs with integral bushings
• Large machine screws for fastening covers to bodies
• Lockout provisions on front operated pushbutton (marked "STOP"
and "OFF") and selector switch covers
• Lockout hole for padlock having 1/ 4" hasp is provided when used
with covers for front lever and side rocker type operation
• Close tolerances in machining of wide, mating flanges and
journalled shafts and bearings for front button operation, produces
flametightness of enclosure joints
• On enclosures with front lever and side rocker type operating
handles, threaded type shafts and bushings are used to ensure
flametightness
• Dead end (EFS or EDS) or through feed (EFSC or EDSC) hubs – 1/2"
to 1" sizes
• When STOP is indicated, button is automatically red. When START
is indicated, button is automatically green. Otherwise, black
buttons are standard.

Standard Materials:
• Bodies – Feraloy® iron alloy; copper-free aluminum
• Front operated pushbutton and pilot light covers – Feraloy iron
alloy
• Side operated type pushbutton covers – copper-free aluminum
• Shafts – stainless steel
• Shaft bushings – stainless steel
• Rocker handle and pushbutton guards – type 6 / 6 nylon
• Sealing enclosures – copper-free aluminum

Standard Finishes:
• Feraloy iron alloy – electrogalvanized and aluminum acrylic paint
• Copper-free aluminum – natural
• Type 6 / 6 nylon – black
• Stainless steel – natural

Options:

The following special options are available from the factory by
adding suffix to Cat. #:
Description
Suffix
• Emergency "Stop" button (momentary) – front operated red
mushroom button .................................................................... S111
• Lockout provision on front operated pushbutton cover
(standard on buttons marked "OFF" and "STOP").................. S153
• For 24 VDC operation on pilot lights ....................................... S300
• Three-position selector switches with modified operation:
Momentary contact clockwise operation, spring return to
center, maintained contact counter-clockwise operation
S634
Momentary contact counter-clockwise operation, spring
return to center, maintained contact clockwise operation.... S635
• Bodies and covers (single and two gang units) – copper-free
aluminum..................................................................................
SA
• Where indicated in the catalog listings, EDS units suitable
for Class I, Division 1, Group B usage can be supplied, add
suffix -GB, EFS units are suitable for Class I, Division 1,
Group B as standard ...............................................................
GB
• Maintained contact mushroom head with lockout. May not
be combined with a pilot light if a transformer is required.
(Push to stop only) ................................................................... S769
• Spring return to center from right and left............................... S842
EDS bodies and factory sealed cover and device sub-assemblies are
available for field assembly (see page 521).

*See suffix GB in Options section

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2014 Eaton’s Crouse-Hinds Business

4C

Features:

4C

Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG

EDS / EFS Series
Control Stations

4C

Fully Assembled EFS and
EDS Factory Sealed Devices

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Methods of Factory Sealing
EDS Series

Factory sealed EDS and EFS pilot light, pushbutton and selector
switch control stations do not need external sealing. Device contacts
are factory sealed in explosionproof ESWP contact blocks. Small,
compact enclosures have accurately ground wide flanges on both
the body and cover for a flame-tight joint.

EDS factory sealed snap switches or manual motor starting switches
do not need external sealing. The switches are enclosed in a unique
sealing well with double flanges which mate with the cover and the
body. Small, compact enclosures have accurately ground wide
flanges on body, cover and sealing well for flame-tight joints. Wiring
pigtails are factory sealed from under the sealing well. Reliable
pouring of seals at the factory ensures safe sealing.

4C

EFS/EDS Series

Dimensions (Inches) ‡

Covers†

Bodies

Hub
Size
1
/2
3
/4
1

Dim. Dim.
"h"
"i"
/4
/8
1

3
7

/16
/16
/16

13
13
15

Front View - Single gang

Pushbutton switch rocker type
side operated

Side View

General use snap switch
front operated and manual
motor starting switch

Pushbutton switch front
operated

Selector switch

Front View - Two gang

*See suffix GB in Options section.
‡Dimensions are approximate, not for construction purposes.
† Surface covers have same length and width as bodies.

526

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

EDS / EFS Series Control Stations
Fully Assembled EDS Factory Sealed
General Use Snap Switches

Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

4C

Dimensions
see page 526

EDSC2129

EDS2229

Ordering Information - General Use Snap Switch – Front Operated
4C

Single Gang

Two Gang‡

Amperes
Style†

120VAC§

277VAC§

Dead End
Cat. #

Through
Feed Cat. #

Dead End
Cat. #

Through
Feed Cat. #

Factory Sealed
Replacement
Switch

1-pole
2-pole

20
20

20
20

EDS2129
EDS218

EDSC2129†
EDSC218†

EDS2229

/4

EDSC2229†
EDSC228†

SW5
SW6

/4

3-way

20

20

EDS2130

EDSC2130

EDS2230

/4
1

4-way

20

20

EDS2140

EDSC2140

1-pole

20

20

EDS3129

EDSC3129†

EDS3229

1

2-pole

20

20

EDS318

EDSC318†

1

3-way

20

20

EDS3130

EDSC3130

1

4-way

20

20

EDS3140

EDSC3140

Hub
Size
/4

3

3

3

3

EDSC2230

SW7

EDSC2240

SW8

EDSC3229†

SW5

EDS328

EDSC328†

SW6

EDS3230

EDSC3230

SW7

EDS3240

EDSC3240

SW8

*Standard as Class I, Division 2, Group B. No seals required. For Class I, Division 1, Group B: All units on this page can be modified for Class I, Division 1, Group B
usage. Add suffix GB to the Cat. No. Seals must be installed within 11/ 2" of each conduit opening in Division 1.
† ON-OFF standard marking for 1-pole and 2-pole units.
‡ Combinations of switches can be furnished.
§ AC rated switches are tested for resistive, inductive and tungsten filament loads up to the full current rating and for motor loads up to 80% of the ampere rating.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

535

For a complete list of components for EDS &
EFS Control Stations, see page 514 for
FlexStation™ Series

EDS / EFS Series
Control Stations

4C

Sub-assembly Reference Guide
Control Stations and their Sub-assemblies
Complete Control
Station

Sub-assembly
Cover & Device

Cast Back Box

PUSHBUTTONS
EDS2184
EDSC2184
EDS215
EDSC215
EDS2190
EDSC2190
EDS2184-S769-EM-SP
EDSC2184-S769-EM-SP
EDS2284
EDSC2284
EDS225
EDSC225
EDS2290
EDSC2290

DSD918
DSD918
DSD922
DSD922
DSD921
DSD921
DSD918-S769-EM-SP
DSD918-S769-EM-SP
(2) DSD918
(2) DSD918
(2) DSD922
(2) DSD922
(2) DSD921
(2) DSD921

EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS272
EDSC272
EDS272
EDSC272
EDS272
EDSC272

PILOT LIGHTS
EFS21524-J*
EFSC21524-J*
EFS21561-J*-J*
EFSC21561-J*-J*

DSD948-J*
DSD948-J*
DSD947-J*-J*
DSD947-J*-J*

EDS271 †
EDSC271 †
EDS271 †
EDSC271 †

* Insert pilot light color
† When using the EFS Series pilot light in Cl. I, Div. 1, Group B
applications, the EFS back box is required in place of the EDS.

PUSHBUTTON / PILOT LIGHT COMBINATIONS
EDS21473-J*
DSD958-J*
EDSC21473-J*
DSD958-J*
EDS22471-J*
DSD948-J* & DSD921
EDSC22471-J*
DSD948-J* & DSD921
EDS22868-J*-J*
DSD947-J*-J* & DSD921
EDSC22868-J*-J*
DSD947-J*-J* & DSD921

EDS271
EDSC271
EDS272
EDSC272
EDS272
EDSC272

*
*
*
*
*
*

SELECTOR SWITCHES
EDS21271
EDSC21271
EDS21272
EDSC21272
EDS21273
EDSC21273
EDS21274
EDSC21274
EDS21275
EDSC21275

EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271

MANUAL MOTOR STARTER WITH O/L
EDS21101
DS415A & SW13
EDSC21101
DS415A & SW13
EDS21102
DS415A & SW14
EDSC21102
DS415A & SW14
EDS21093
DS415A & SW11
EDSC21093
DS415A & SW11
EDS21094
DS415A & SW12
EDSC21094
DS415A & SW12
EDS2199
DS415A & SW9
EDSC2199
DS415A & SW9
EDS21100
DS415A & SW10
EDSC21100
DS415A & SW10

www.crouse-hinds.com

EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271

US: 1-866-764-5454

Start/ Stop Legend included
Start/ Stop Legend included

Emergency Stop Legend included
Emergency Stop Legend included

4C

DSD923
DSD923
DSD924
DSD924
DSD925
DSD925
DSD926
DSD926
DSD927
DSD927

Notes and Requirements

Start/ Stop Legend included
Start/ Stop Legend included

Insert
Insert
Insert
Insert
Insert
Insert

pilot
pilot
pilot
pilot
pilot
pilot

light
light
light
light
light
light

color
color
color
color
color
color

"-W * " for heater, or "-0" distributor provided
"-W * " for heater, or "-0" distributor provided
"-W * " for heater, or "-0" distributor provided
"-W * " for heater, or "-0" distributor provided
"-G * " for heater, or "-0" distributor provided
"-G * " for heater, or "-0" distributor provided
"-G * " for heater, or "-0" distributor provided
"-G * " for heater, or "-0" distributor provided
"-P * " for heater, or "-0" distributor provided
"-P * " for heater, or "-0" distributor provided
"-P * " for heater, or "-0" distributor provided
"-P * " for heater, or "-0" distributor provided

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

539

EDS / EFS Series Control Stations

4C

Sub-assembly
Reference Guide

For a complete list of components for
EDS & EFS Control Stations, see page 514
for FlexStation™ Series

Control Stations and their Sub-assemblies

4C

Sub-assembly
Complete Control Station

Cover & Device

Cast Back Box

MANUAL MOTOR STARTER
EFD218-T8
Alternative
EFDC218-T8
Alternative
EFD2419
Alternative
EFDC2419
Alternative

DSD916
DS415A &
DSD916
DS415A &
DSD917
DS415A &
DSD917
DS415A &

EDS271
EDS271
EDSC271
EDSC271
EDS271
EDS271
EDSC271
EDSC271

SNAP SWITCHES
EDS2129
Alternative
EDSC2129
Alternative
EDS218
Alternative
EDSC218
Alternative
EDS2130
Alternative
EDSC2130
Alternative
EDS2140
Alternative
EDSC2140
Alternative
EDS2229
Alternative
EDSC2229
Alternative
EDSC228
Alternative
EDS2230
Alternative
EDSC2230
Alternative
EDSC2240
Alternative

DS652 & SW5
DSD933
DS652 & SW5
DSD933
DS652 & SW6
DSD634
DS652 & SW6
DSD634
DS652 & SW7
DSD936
DS652 & SW7
DSD936
DS652 & SW8
DSD937
DS652 & SW8
DSD937
(2) DS652 & (2)
(2) DSD933
(2) DS652 & (2)
(2) DSD933
(2) DS652 & (2)
(2) DSD634
(2) DS652 & (2)
(2) DSD936
(2) DS652 & (2)
(2) DSD936
(2) DS652 & (2)
(2) DSD937

ROCKER SWITCHES
EDS2596
EDSC2596
EDS2162
EDSC2162
EDS2194
EDSC2194
EDS2696
EDSC2696
EDS2262
EDSC2262
EDS2294
EDSC2294

DSD949
DSD949
DSD951
DSD951
DSD950
DSD950
(2) DSD949
(2) DSD949
(2) DSD951
(2) DSD951
(2) DSD950
(2) DSD950

•
•
•
•
•
•
•
•
•
•
•
•

SQ D 2510 KO-1
SQ D 2510 KO-1
GE 2368S
GE 2368S

SW5
SW5
SW6
SW7
SW7
SW8

EDS271
EDS271
EDSC271
EDSC271
EDS271
EDS271
EDSC271
EDSC271
EDS271
EDS271
EDSC271
EDSC271
EDS271
EDS271
EDSC271
EDSC271
EDS272
EDS272
EDSC272
EDSC272
EDSC272
EDSC272
EDS272
EDS272
EDSC272
EDSC272
EDSC272
EDSC272
EDS271
EDSC271
EDS271
EDSC271
EDS271
EDSC271
EDS272
EDSC272
EDS272
EDSC272
EDS272
EDSC272

Notes and Requirements

SQ D switch provided by distributor
SQ D switch provided by distributor
GE switch provided by distributor
GE switch provided by distributor

External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required
External Sealing Fitting Required

Start/ Stop Legend included
Start/ Stop Legend included
Start/ Stop Legend included
Start/ Stop Legend included

Additional notes:
See Eaton's Crouse-Hinds' installation instructions for any possible additional sealing requirements.
Part numbers listed with 3/ 4" hub in back box (Ex. EDS2184). For 1/ 2" hub, change the "2" to "1" (EDS1184). For 1" hub, change the "2" to "3" (EDS3184).
Control Stations with "Stop" legend have lockout provided as standard.
Pilot Light Colors J*-- J1= Red, J3= Green, J6= Amber, J10= Clear, J11= Blue. LED pilot lights are available with LED suffix.
Pilot Light Transformers for voltages over 125V. Suffix T2= 240/220 - 110V, T4= 480/440 - 110V, T5= 600/500 - 110V (not available on double pilot cover).
Standard legend plate markings are available by adding nomenclature after the part number (EDS2184-Run).
Selector switch nameplate kits available. 2-Pos = "SS2KIT", 3-Pos = "SS3KIT". See Replacement Parts book for additional information.
Copper-free aluminum bodies and covers available with SA suffix.
Additional control station options may be found in Section 4C.
Group B ratings may be achieved by adding the GB suffix or using the EFS back box. See part number instructions for the item required.
Group B ratings may already be achieved when used in Class I, Division 2 applications. See Certifications and Compliances for item required.
Additional control station configurations available through the FlexStation Component Series.

540

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : mabe
Create Date                     : 2014:10:10 11:02:03-04:00
Modify Date                     : 2014:10:10 11:02:03-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2014:10:10 11:01:49-04:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Creator                         : mabe
Title                           : eds-snap-switch-control-station.pdf
Document ID                     : uuid:645dd28c-2c47-4019-bf7c-410b3761848d
Instance ID                     : uuid:c5d17d35-0794-4b28-a690-02d14afcd050
Producer                        : Acrobat Distiller 10.0.0 (Windows)
Page Count                      : 5
EXIF Metadata provided by EXIF.tools