Eds Snap Switch Control Station

2014-10-17

: Pdf 123400-Attachment 123400-Attachment 782274 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 5

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2014 Eaton’s Crouse-Hinds Business
4C
EDS / EFS Series
Control Stations
Fully Assembled EFS and
EDS Factory Sealed Devices
Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Applications:
Factory sealed enclosures are installed in a rigid metallic conduit
system for surface mounting adjacent to or remote from equipment
being controlled and are used:
•To prevent arcing of enclosed device from causing ignition of a
specific hazardous atmosphere or atmospheres external to the
enclosure
•In industrial areas such as chemical plants, oil and gas refineries,
paint and varnish manufacturing plants, gasoline bulk loading
terminals, grain elevators, grain processing industries, coal
processing or handling areas, or metal handling or finishing areas
where atmosphere may contain hazardous gases and/or dust
•In non-hazardous areas where sturdy, durable enclosures are
required
•In conjunction with magnetic starters or contactors for remote
control of motors
Manual motor starting switch enclosures are used:
•For manual starting of small AC or DC motors
•To provide manual starting and stopping and, in the case of units
with heaters, motor running protection
Certifications and Compliances:
•NEC/CEC:
Class I, Division 1 & 2, Groups B*, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
•NEMA/EEMAC: 3, 7B*CD, 9EFG
•UL Standard: 1203
•CSA Standard: C22.2 No. 30
Standard Materials:
•Bodies – Feraloy®iron alloy; copper-free aluminum
•Front operated pushbutton and pilot light covers – Feraloy iron
alloy
•Side operated type pushbutton covers – copper-free aluminum
•Shafts – stainless steel
•Shaft bushings – stainless steel
•Rocker handle and pushbutton guards – type 6 / 6 nylon
•Sealing enclosures – copper-free aluminum
Standard Finishes:
•Feraloy iron alloy – electrogalvanized and aluminum acrylic paint
•Copper-free aluminum – natural
•Type 6 / 6 nylon – black
•Stainless steel – natural
EDS bodies and factory sealed cover and device sub-assemblies are
available for field assembly (see page 521).
*See suffix GB in Options section
4C
Features:
Factory sealed devices have many distinct advantages:
•Reduce installation problems
•Eliminate external seals
•Lower installation costs
•Improve safety
•Are used with general purpose snap and pushbutton type switches
•Standard neoprene covers for front operated pushbuttons. Prevents
accumulation of dirt and entrance of water around operating shafts
•Mounting lugs and taper tapped hubs with integral bushings
•Large machine screws for fastening covers to bodies
•Lockout provisions on front operated pushbutton (marked "STOP"
and "OFF") and selector switch covers
•Lockout hole for padlock having 1/4" hasp is provided when used
with covers for front lever and side rocker type operation
•Close tolerances in machining of wide, mating flanges and
journalled shafts and bearings for front button operation, produces
flametightness of enclosure joints
•On enclosures with front lever and side rocker type operating
handles, threaded type shafts and bushings are used to ensure
flametightness
•Dead end (EFS or EDS) or through feed (EFSC or EDSC) hubs – 1/2"
to 1" sizes
•When STOP is indicated, button is automatically red. When START
is indicated, button is automatically green. Otherwise, black
buttons are standard.
Options:
The following special options are available from the factory by
adding suffix to Cat. #:
Description Suffix
•Emergency "Stop" button (momentary) – front operated red
mushroom button .................................................................... S111
•Lockout provision on front operated pushbutton cover
(standard on buttons marked "OFF" and "STOP").................. S153
•For 24 VDC operation on pilot lights ....................................... S300
•Three-position selector switches with modified operation:
Momentary contact clockwise operation, spring return to
center, maintained contact counter-clockwise operation S634
Momentary contact counter-clockwise operation, spring
return to center, maintained contact clockwise operation.... S635
•Bodies and covers (single and two gang units) – copper-free
aluminum.................................................................................. SA
•Where indicated in the catalog listings, EDS units suitable
for Class I, Division 1, Group B usage can be supplied, add
suffix -GB, EFS units are suitable for Class I, Division 1,
Group B as standard ............................................................... GB
•Maintained contact mushroom head with lockout. May not
be combined with a pilot light if a transformer is required.
(Push to stop only) ................................................................... S769
•Spring return to center from right and left............................... S842
4C
526
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2013 Eaton’s Crouse-Hinds Business
4C EDS / EFS Series
Control Stations
Fully Assembled EFS and
EDS Factory Sealed Devices
Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Methods of Factory Sealing
EFS/EDS Series
Factory sealed EDS and EFS pilot light, pushbutton and selector
switch control stations do not need external sealing. Device contacts
are factory sealed in explosionproof ESWP contact blocks. Small,
compact enclosures have accurately ground wide flanges on both
the body and cover for a flame-tight joint.
EDS Series
EDS factory sealed snap switches or manual motor starting switches
do not need external sealing. The switches are enclosed in a unique
sealing well with double flanges which mate with the cover and the
body. Small, compact enclosures have accurately ground wide
flanges on body, cover and sealing well for flame-tight joints. Wiring
pigtails are factory sealed from under the sealing well. Reliable
pouring of seals at the factory ensures safe sealing.
Dimensions (Inches) ‡
Side View
Front View - Single gang Front View - Two gang
Hub
Size
Dim.
"h"
Dim.
"i"
1
/
23
/
413
/
16
3
/
47
/
813
/
16
11
15
/
16
General use snap switch
front operated and manual
motor starting switch
Pushbutton switch rocker type
side operated
Pushbutton switch front
operated
Selector switch
*See suffix GB in Options section.
‡Dimensions are approximate, not for construction purposes.
† Surface covers have same length and width as bodies.
Bodies Covers†
4C
535
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2013 Eaton’s Crouse-Hinds Business
EDS / EFS Series Control Stations
Fully Assembled EDS Factory Sealed
General Use Snap Switches
Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
EDSC2129 EDS2229
Ordering Information - General Use Snap Switch – Front Operated
Single Gang Two Gang‡
Amperes Factory Sealed
Replacement
Switch
Hub
Size Style† 120VAC§ 277VAC§
Dead End
Cat. #
Through
Feed Cat. #
Dead End
Cat. #
Through
Feed Cat. #
3/41-pole 20 20 EDS2129 EDSC2129† EDS2229 EDSC2229† SW5
3/42-pole 20 20 EDS218 EDSC218† EDSC228† SW6
3/43-way 20 20 EDS2130 EDSC2130 EDS2230 EDSC2230 SW7
3/44-way 20 20 EDS2140 EDSC2140 EDSC2240 SW8
1 1-pole 20 20 EDS3129 EDSC3129† EDS3229 EDSC3229† SW5
12-pole 20 20 EDS318 EDSC318† EDS328 EDSC328† SW6
13-way 20 20 EDS3130 EDSC3130 EDS3230 EDSC3230 SW7
14-way 20 20 EDS3140 EDSC3140 EDS3240 EDSC3240 SW8
Dimensions
see page 526
*Standard as Class I, Division 2, Group B. No seals required. For Class I, Division 1, Group B:All units on this page can be modified for Class I, Division 1, Group B
usage. Add suffix GB to the Cat. No. Seals must be installed within 11/2" of each conduit opening in Division 1.
† ON-OFF standard marking for 1-pole and 2-pole units.
‡ Combinations of switches can be furnished.
§ AC rated switches are tested for resistive, inductive and tungsten filament loads up to the full current rating and for motor loads up to 80% of the ampere rating.
4C
539
4C
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2013 Eaton’s Crouse-Hinds Business
4C
EDS / EFS Series
Control Stations
Sub-assembly Reference Guide
For a complete list of components for EDS &
EFS Control Stations, see page 514 for
FlexStation™ Series
Control Stations and their Sub-assemblies
Complete Control
Station
Sub-assembly
Notes and RequirementsCover & Device Cast Back Box
PUSHBUTTONS
EDS2184 DSD918 EDS271
EDSC2184 DSD918 EDSC271
EDS215 DSD922 EDS271 Start/ Stop Legend included
EDSC215 DSD922 EDSC271 Start/ Stop Legend included
EDS2190 DSD921 EDS271
EDSC2190 DSD921 EDSC271
EDS2184-S769-EM-SP DSD918-S769-EM-SP EDS271 Emergency Stop Legend included
EDSC2184-S769-EM-SP DSD918-S769-EM-SP EDSC271 Emergency Stop Legend included
EDS2284 (2) DSD918 EDS272
EDSC2284 (2) DSD918 EDSC272
EDS225 (2) DSD922 EDS272 Start/ Stop Legend included
EDSC225 (2) DSD922 EDSC272 Start/ Stop Legend included
EDS2290 (2) DSD921 EDS272
EDSC2290 (2) DSD921 EDSC272
PILOT LIGHTS
EFS21524-J* DSD948-J* EDS271 † * Insert pilot light color
† When using the EFS Series pilot light in Cl. I, Div. 1, Group B
applications, the EFS back box is required in place of the EDS.
EFSC21524-J* DSD948-J* EDSC271 †
EFS21561-J*-J* DSD947-J*-J* EDS271 †
EFSC21561-J*-J* DSD947-J*-J* EDSC271 †
PUSHBUTTON / PILOT LIGHT COMBINATIONS
EDS21473-J* DSD958-J* EDS271 * Insert pilot light color
EDSC21473-J* DSD958-J* EDSC271 * Insert pilot light color
EDS22471-J* DSD948-J* & DSD921 EDS272 * Insert pilot light color
EDSC22471-J* DSD948-J* & DSD921 EDSC272 * Insert pilot light color
EDS22868-J*-J* DSD947-J*-J* & DSD921 EDS272 * Insert pilot light color
EDSC22868-J*-J* DSD947-J*-J* & DSD921 EDSC272 * Insert pilot light color
SELECTOR SWITCHES
EDS21271 DSD923 EDS271
EDSC21271 DSD923 EDSC271
EDS21272 DSD924 EDS271
EDSC21272 DSD924 EDSC271
EDS21273 DSD925 EDS271
EDSC21273 DSD925 EDSC271
EDS21274 DSD926 EDS271
EDSC21274 DSD926 EDSC271
EDS21275 DSD927 EDS271
EDSC21275 DSD927 EDSC271
MANUAL MOTOR STARTER WITH O/L
EDS21101 DS415A & SW13 EDS271 "-W * " for heater, or "-0" distributor provided
EDSC21101 DS415A & SW13 EDSC271 "-W * " for heater, or "-0" distributor provided
EDS21102 DS415A & SW14 EDS271 "-W * " for heater, or "-0" distributor provided
EDSC21102 DS415A & SW14 EDSC271 "-W * " for heater, or "-0" distributor provided
EDS21093 DS415A & SW11 EDS271 "-G * " for heater, or "-0" distributor provided
EDSC21093 DS415A & SW11 EDSC271 "-G * " for heater, or "-0" distributor provided
EDS21094 DS415A & SW12 EDS271 "-G * " for heater, or "-0" distributor provided
EDSC21094 DS415A & SW12 EDSC271 "-G * " for heater, or "-0" distributor provided
EDS2199 DS415A & SW9 EDS271 "-P * " for heater, or "-0" distributor provided
EDSC2199 DS415A & SW9 EDSC271 "-P * " for heater, or "-0" distributor provided
EDS21100 DS415A & SW10 EDS271 "-P * " for heater, or "-0" distributor provided
EDSC21100 DS415A & SW10 EDSC271 "-P * " for heater, or "-0" distributor provided
540
4C
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2013 Eaton’s Crouse-Hinds Business
Control Stations and their Sub-assemblies
Complete Control Station
Sub-assembly
Notes and RequirementsCover & Device Cast Back Box
MANUAL MOTOR STARTER
EFD218-T8 DSD916 EDS271
Alternative DS415A & SQ D 2510 KO-1 EDS271 SQ D switch provided by distributor
EFDC218-T8 DSD916 EDSC271
Alternative DS415A & SQ D 2510 KO-1 EDSC271 SQ D switch provided by distributor
EFD2419 DSD917 EDS271
Alternative DS415A & GE 2368S EDS271 GE switch provided by distributor
EFDC2419 DSD917 EDSC271
Alternative DS415A & GE 2368S EDSC271 GE switch provided by distributor
SNAP SWITCHES
EDS2129 DS652 & SW5 EDS271
Alternative DSD933 EDS271 External Sealing Fitting Required
EDSC2129 DS652 & SW5 EDSC271
Alternative DSD933 EDSC271 External Sealing Fitting Required
EDS218 DS652 & SW6 EDS271
Alternative DSD634 EDS271 External Sealing Fitting Required
EDSC218 DS652 & SW6 EDSC271
Alternative DSD634 EDSC271 External Sealing Fitting Required
EDS2130 DS652 & SW7 EDS271
Alternative DSD936 EDS271 External Sealing Fitting Required
EDSC2130 DS652 & SW7 EDSC271
Alternative DSD936 EDSC271 External Sealing Fitting Required
EDS2140 DS652 & SW8 EDS271
Alternative DSD937 EDS271 External Sealing Fitting Required
EDSC2140 DS652 & SW8 EDSC271
Alternative DSD937 EDSC271 External Sealing Fitting Required
EDS2229 (2) DS652 & (2) SW5 EDS272
Alternative (2) DSD933 EDS272 External Sealing Fitting Required
EDSC2229 (2) DS652 & (2) SW5 EDSC272
Alternative (2) DSD933 EDSC272 External Sealing Fitting Required
EDSC228 (2) DS652 & (2) SW6 EDSC272
Alternative (2) DSD634 EDSC272 External Sealing Fitting Required
EDS2230 (2) DS652 & (2) SW7 EDS272
Alternative (2) DSD936 EDS272 External Sealing Fitting Required
EDSC2230 (2) DS652 & (2) SW7 EDSC272
Alternative (2) DSD936 EDSC272 External Sealing Fitting Required
EDSC2240 (2) DS652 & (2) SW8 EDSC272
Alternative (2) DSD937 EDSC272 External Sealing Fitting Required
ROCKER SWITCHES
EDS2596 DSD949 EDS271
EDSC2596 DSD949 EDSC271
EDS2162 DSD951 EDS271 Start/ Stop Legend included
EDSC2162 DSD951 EDSC271 Start/ Stop Legend included
EDS2194 DSD950 EDS271
EDSC2194 DSD950 EDSC271
EDS2696 (2) DSD949 EDS272 Start/ Stop Legend included
EDSC2696 (2) DSD949 EDSC272 Start/ Stop Legend included
EDS2262 (2) DSD951 EDS272
EDSC2262 (2) DSD951 EDSC272
EDS2294 (2) DSD950 EDS272
EDSC2294 (2) DSD950 EDSC272
Additional notes:
• See Eaton's Crouse-Hinds' installation instructions for any possible additional sealing requirements.
• Part numbers listed with 3/4" hub in back box (Ex. EDS2184). For 1/2" hub, change the "2" to "1" (EDS1184). For 1" hub, change the "2" to "3" (EDS3184).
• Control Stations with "Stop" legend have lockout provided as standard.
• Pilot Light Colors J*-- J1= Red, J3= Green, J6= Amber, J10= Clear, J11= Blue. LED pilot lights are available with LED suffix.
• Pilot Light Transformers for voltages over 125V. Suffix T2= 240/220 - 110V, T4= 480/440 - 110V, T5= 600/500 - 110V (not available on double pilot cover).
• Standard legend plate markings are available by adding nomenclature after the part number (EDS2184-Run).
• Selector switch nameplate kits available. 2-Pos = "SS2KIT", 3-Pos = "SS3KIT". See Replacement Parts book for additional information.
• Copper-free aluminum bodies and covers available with SA suffix.
• Additional control station options may be found in Section 4C.
• Group B ratings may be achieved by adding the GB suffix or using the EFS back box. See part number instructions for the item required.
• Group B ratings may already be achieved when used in Class I, Division 2 applications. See Certifications and Compliances for item required.
• Additional control station configurations available through the FlexStation Component Series.
4C EDS / EFS Series Control Stations
Sub-assembly
Reference Guide
For a complete list of components for
EDS & EFS Control Stations, see page 514
for FlexStation™ Series

Navigation menu